Sample records for rotary screw expander



    The article presents results of research of rotary-screw systems in relation to the creation of rotary kilns for the annealing of-cuttings in the preparation of cement clinker. Using the proposed design, in comparison with known designs of similar purpose, it significantly improves performance, reduces size and power consumption through the use of rotary screw systems in the form of screw rotors and drums made hollow with sidewalls assembled from separate strips or plates of different geometr...

  2. Helical Screw Expander Evaluation Project. Final report

    McKay, R.


    A functional 1-MW geothermal electric power plant that featured a helical screw expander was produced and then tested in Utah in 1978 to 1979 with a demonstrated average performance of approximately 45% machine efficiency over a wide range of test conditions in noncondensing operation on two-phase geothermal fluids. The Project also produced a computer-equipped data system, an instrumentation and control van, and a 1000-kW variable load bank, all integrated into a test array designed for operation at a variety of remote test sites. Additional testing was performed in Mexico in 1980 under a cooperative test program using the same test array, and machine efficiency was measured at 62% maximum with the rotors partially coated with scale, compared with approximately 54% maximum in Utah with uncoated rotors, confirming the importance of scale deposits within the machine on performance. Data are presented for the Utah testing and for the noncondensing phases of the testing in Mexico. Test time logged was 437 hours during the Utah tests and 1101 hours during the Mexico tests.

  3. 3D CFD analysis of a twin screw expander

    Kovacevic, A.; S Rane


    Twin screw machines can be used as expanders for variety of applications. This paper describes how the performance of an oil free twin screw air expander of 3/5 lobe configuration was estimated by use of full 3D Computational Fluid Dynamics (CFD) applying a procedure similar to that used for screw compressors. The grid generator SCORG© was employed for pre-processing of the moving domains between the rotors while the stationary grids for the ports were derived from a commercial grid generator...

  4. Theoretical investigation of flash vaporisation in a screw expander

    Vasuthevan, Hanushan; Brümmer, Andreas


    In the present study flash vaporisation of liquid injection in a twin screw expander for a Trilateral Flash Cycle (TFC) is examined theoretically. The TFC process comprises a pressure increase in the working fluid, followed by heating the liquid close to boiling point. The hot liquid is injected into the working chamber of a screw expander. During this process the pressure of the liquid drops below the saturation pressure, while the temperature of the liquid remains virtually constant. Hence the liquid is superheated and in a metastable state. The liquid jet seeks to achieve a stable state in thermodynamic equilibrium and is therefore partially vaporised. This effect is referred to as flash vaporisation. Accordingly, a two-phase mixture, consisting of vapour and liquid, exists in the working chamber. Thermodynamic simulations were carried out using water as the working fluid for representative screw expander geometry. The simulations presented are performed from two different aspects during the filling process of a screw expander. The first case is the vaporisation of the injected liquid in a state of thermodynamic equilibrium, whereby the two-phase mixture is treated entirely as a compressible and homogeneous gas. The second case considers flashing efficiency. It describes the quantity of flashed vapour and consists of a liquid and vapour domain. Both models are compared and analysed with respect to the operational behaviour of a screw expander.

  5. Numerical simulation of a twin screw expander for performance prediction

    Papes, Iva; Degroote, Joris; Vierendeels, Jan


    With the increasing use of twin screw expanders in waste heat recovery applications, the performance prediction of these machines plays an important role. This paper presents a mathematical model for calculating the performance of a twin screw expander. From the mass and energy conservation laws, differential equations are derived which are then solved together with the appropriate Equation of State in the instantaneous control volumes. Different flow processes that occur inside the screw expander such as filling (accompanied by a substantial pressure loss) and leakage flows through the clearances are accounted for in the model. The mathematical model employs all geometrical parameters such as chamber volume, suction and leakage areas. With R245fa as working fluid, the Aungier Redlich-Kwong Equation of State has been used in order to include real gas effects. To calculate the mass flow rates through the leakage paths formed inside the screw expander, flow coefficients are considered as constant and they are derived from 3D Computational Fluid Dynamic calculations at given working conditions and applied to all other working conditions. The outcome of the mathematical model is the P-V indicator diagram which is compared to CFD results of the same twin screw expander. Since CFD calculations require significant computational time, developed mathematical model can be used for the faster performance prediction.

  6. Twin screw two-phase expanders in large chiller units

    Smith, I.K.; Stosic, N.; Aldis, C.A.; Kovacevic, A. [City Univ., Dept. of Mechanical Engineering and Aeronautics, London (United Kingdom)


    An investigation was carried out to determine the feasibility of the use of a twin screw expander as a throttle valve replacement in a 500 ton chiller. The aim was to produce a demonstration unit with an overall machine adiabatic efficiency of not less that 70%. The efficiency target was effectively met but further analytical work is needed to predict mass flow rates reliably and hence the exact machine size required when refrigerant enters the expander as subcooled liquid. (Author)

  7. A new alternative to expandable pedicle screws: Expandable poly-ether-ether-ketone shell.

    Demir, Teyfik


    Screw pullout is a very common problem in the fixation of sacrum with pedicle screws. The principal cause of this problem is that the cyclic micro motions in the fixation of sacrum are higher than the other regions of the vertebrae that limit the osteo-integration between bone and screw. In addition to that, the bone quality is very poor at sacrum region. This study investigated a possible solution to the pullout problem without the expandable screws' handicaps. Newly designed poly-ether-ether-ketone expandable shell and classical pedicle screws were biomechanically compared. Torsion test, pullout tests, fatigue tests, flexion/extension moment test, axial gripping capacity tests and torsional gripping capacity tests were conducted in accordance with ASTM F543, F1798 and F1717. Standard polyurethane foam and calf vertebrae were used as embedding medium for pullout tests. Classical pedicle screw pullout load on polyurethane foam was 564.8 N compared to the failure load for calf vertebrae's 1264 N. Under the same test conditions, expandable poly-ether-ether-ketone shell system's pullout loads from polyurethane foam and calf vertebrae were 1196.3 and 1890 N, respectively. The pullout values for expandable poly-ether-ether-ketone shell were 33% and 53% higher than classical pedicle screw on polyurethane foam and calf vertebrae, respectively. The expandable poly-ether-ether-ketone shell exhibited endurance on its 90% of yield load. Contrary to poly-ether-ether-ketone shell, classical pedicle screw exhibited endurance on 70% of its yield load. Expandable poly-ether-ether-ketone shell exhibited much higher pullout performance than classical pedicle screw. Fatigue performance of expandable poly-ether-ether-ketone shell is also higher than classical pedicle screw due to damping the micro motion capacity of the poly-ether-ether-ketone. Expandable poly-ether-ether-ketone shell is a safe alternative to all other expandable pedicle screw systems on mechanical perspective

  8. The helical screw expander evaluation project. [for geothermal wells

    Mckay, R. A.


    A positive-displacement helical-screw expander of the Lysholm type has been adapted for geothermal service and successfully demonstrated in a 50 kW prototype power system. Evaluation of the expander by tests of a new model in a 1 MW power system under wellhead conditions in selected liquid-dominated geothermal fields is proposed. The objectives are to determine the performance characteristics of the expander and power system over a broad range of operating conditions and also to examine the concept of wellhead power plants. Throttling and fractionation of the fluids from the test wells is planned to simulate a wide range of wellhead pressures and steam fractions. Variation in the expander exhaust pressure is also planned. The investigation will include expander efficiency, corrosion, erosion, scale formation and control, and endurance testing. Interaction studies with the wells and an electric grid are also proposed.

  9. Pullout performance comparison of novel expandable pedicle screw with expandable poly-ether-ether-ketone shells and cement-augmented pedicle screws.

    Aycan, Mehmet Fatih; Tolunay, Tolga; Demir, Teyfik; Yaman, Mesut Emre; Usta, Yusuf


    Aim of this study is to assess the pullout performance of various pedicle screws in different test materials. Polyurethane foams (Grade 10 and Grade 40) produced in laboratory and bovine vertebrae were instrumented with normal, cannulated (cemented), novel expandable and normal (cemented) pedicle screws. Test samples were prepared according to the ASTM F543 standard testing protocols and surgical guidelines. To examine the screw placement and cement distribution, anteriosuperior and oblique radiographs were taken from each sample after insertion process was completed. Pullout tests were performed in an Instron 3369 testing device. Load versus displacement graphs were recorded and the ultimate pullout force was defined as the maximum load (pullout strength) sustained before failure of screw. Student's t-test was performed on each group whether the differences between pullout strength of pedicle screws were significant or not. While normal pedicle screws have the lowest pullout strength in all test materials, normal pedicle screws cemented with polymethylmethacrylate exhibit significantly higher pullout performance than others. For all test materials, there is a significant improvement in pullout strength of normal screws by augmentation. While novel expandable pedicle screws with expandable poly-ether-ether-ketone shells exhibited lower pullout performance than normal screws cemented with polymethylmethacrylate, their pullout performances in all groups were higher than the ones of normal and cannulated pedicle screws. For all test materials, although cannulated pedicle screws exhibit higher pullout strength than normal pedicle screws, there are no significant differences between the two groups. The novel expandable pedicle screws with expandable poly-ether-ether-ketone shells may be used instead of normal and cannulated pedicle screws cemented with polymethylmethacrylate due to their good performances.

  10. Integrated Status and Effectiveness Monitoring Program - Entiat River Snorkel Surveys and Rotary Screw Trap, 2007.

    Nelle, R.D.


    The USFWS Mid-Columbia River Fishery Resource Office conducted snorkel surveys at 24 sites during the summer and fall periods of 2006 survey periods as part of the Integrated Status and Effectiveness Monitoring Program in the Entiat River. A total of 37,938 fish from 15 species/genera and an unknown category were enumerated. Chinook salmon were the overall most common fish observed and comprised 15% of fish enumerated followed by rainbow trout (10%) and mountain whitefish (7%). Day surveys were conducted during the summer period 2007 (August), while night surveys were conducted during the fall 2007 (October) surveys. The USFWS Mid-Columbia River Fishery Resource Office (MCFRO) operated two rotary screw traps on the Entiat River as part of the Integrated Status and Effectiveness Monitoring Program (ISEMP) program from August through November of 2007. Along with the smolt traps, juvenile emigrants were also captured at remote locations throughout the Entiat watershed and its major tributary, the Mad River. A total of 999 wild Oncorhynchus mykiss and 5,107 wild run O. tshawytscha were PIT tagged during the study period. Rotary screw trap efficiencies averaged 22.3% for juvenile O. tshawytscha and 9.0% for juvenile O. mykiss. Rotary screw traps operated 7 days a week and remote capture operations were conducted when flow and temperature regimes permitted. This is third annual progress report to Bonneville Power Administration for the snorkel surveys conducted in the Entiat River as related to long-term effectiveness monitoring of restoration programs in this watershed. The objective of this study is to monitor the fish habitat utilization of planned in-stream restoration efforts in the Entiat River by conducting pre- and post-construction snorkel surveys at selected treatment and control sites.

  11. A rotary drum screen with internal screw flights for Eri silkworm pupae

    Kanjanawanishkul Kiattisin


    Full Text Available Eri silkworm pupae (Samia ricini are very interesting creatures since they can be developed as a sustainable high protein food source for human beings and animals, and their cocoons can be used for silk production. At present, Thai silk is very famous for its special qualities, whereas the requirement of pupae as food grows increasingly, in particular, canned pupae with seasoning favors. Like other food products, size uniformity is required. Therefore, in this paper, a rotary drum screen with internal screw flights was designed and constructed for separating Eri silkworm pupae into two groups with different sizes. The experiments were conducted to evaluate its effectiveness. The results show that the optimal angular speed of the screen was 20 rpm and the screw pitch value was 10 cm. These parameters resulted in the accuracy percentage of pupa screening of 94.3% and the working capacity of 8.6 kg/h.

  12. 'Screw-in' tendency of rotary nickel-titanium files due to design geometry.

    Ha, J H; Cheung, G S P; Versluis, A; Lee, C J; Kwak, S W; Kim, H C


    To examine the effect of several standard geometric characteristics of rotary instruments on the 'screw-in' forces and stresses generated on root dentine using 3D finite element analysis (FEA). Four cross-sectional designs (triangular, slender-rectangular, rectangular and square) were evaluated. The area of the triangular cross-section and of the slender-rectangular model were the same. Another rectangular model had the same centre-core diameter as the triangular one. Each design was twisted into a file model with 5, 10 or 15 threads over its 16-mm-long working section. Three curved root canals were simulated as rigid surface models: θ = 15 degrees/R = 36 mm radius; θ = 30/R = 18; and θ = 45/R = 12. A commercial FEA package was used to simulate the file rotating in the canal to determine the 'screw-in' force and reaction torque on the instrument. Instruments of a square cross-section had the highest 'screw-in' force and reaction torsional stresses followed by the rectangle, the triangle design and the slender-rectangle design, respectively. The file with closer pitch generated lower stresses, compared with that with longer pitch. The greater the root canal curvature, the higher the 'screw-in' force and reaction torque generated. This study demonstrated that the 'screw-in' tendency depends on both the instrument geometry and canal curvature. Clinicians should be aware that certain instrument designs are prone to develop high 'screw-in' forces, requiring the operator to maintain control of the handpiece or to use a brushing action to prevent instruments being pulled into the canal. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  13. 3D CFD analysis of an oil injected twin screw expander

    Papeš, Iva; Degroote, Joris; Vierendeels, Jan


    Small scale Organic Rankine Cycle (ORC) systems have a big potential for waste heat recovery in the market. Due to the smaller volume flows inside these systems, non-conventional expansion technologies such as screw expanders become more interesting. Recent economic studies have shown the important role of screw machines in such cycles. However, in order to get a better understanding of the expansion behaviour in an ORC, appropriate simulation models of screw expanders are necessary. The flow...

  14. Comparison of organic rankine cycle systems under varying conditions using turbine and twin-screw expanders

    Read, M. G.; Smith, I K; Stosic, N.; Kovacevic, A.


    A multi-variable optimization program has been developed to investigate the performance of Organic Rankine Cycles (ORCs) for low temperature heat recovery applications using both turbine and twin-screw expanders when account is taken of performance variation due to changes in ambient conditions. The cycle simulation contains thermodynamic models of both types of expander. In the case of the twin-screw machine, the methods used to match the operation of the expander to the requirements of the ...

  15. Analysis of Indicator Diagrams of a Water Injected Twin-shaft Screw-type Expander

    Nikolov, Alexander; Brümmer, Andreas


    Twin-shaft screw-type expanders offer a high potential for energy conversion in the lower and medium power range, for instance as expansion engines in Rankine cycles for exhaust heat recovery. With regard to minimizing internal leakages and lubricating moving machine parts, an auxiliary liquid or liquid working fluid can be fed to the screw expander. In this paper, indicator diagrams of a twin-shaft screw-type expander prototype designed at the Chair of Fluidics at TU Dortmund University are ...

  16. Optimization of Twin-Screw Superchargers for Combined Compressor - Expander Performance (SCREW); Optimierung von Schraubenladern fuer den kombinierten Verdichtungs- und Expansionsbetrieb (SCREW)

    Romba, M. [Dortmund Univ. (Germany). Fachgebiet Fluidenergiemaschinen


    During the last years the use of mechanical superchargers has gained increasing interest in a bid to combine attractive emission- and fuel consumption values with dynamic driving performance. Based on an analysis of available supercharging systems the development potential of twin screw superchargers is assessed. A concept using inlet slide valves is developed which allows at the same time to control the mass flow delivered by the supercharger and achieve an expansion of the transported charge under part load conditions when the delivered pressure is lower than ambient pressure, achieving a reduction in necessary shaft power or even the delivery of shaft power. To distinguish it from conventional superchargers the new device is called ''SCREW'' - screw type machine with compressor respectively expander working mode. The effect of several design parameters on the SCREW'S performance is evaluated by extensive simulation calculations, showing that a suitable design varies considerably from conventional supercharger designs and that a significant amount of further research, especially covering the development of rotor profiles suited for the specific task, is still needed to fully utilize the concept's potential. As a proof of concept prototype SCREW'S, based on a conventional twin screw supercharger, have been built and tested. The results obtained made clear the general suitability of the concept but also underlined the shortcomings of the prototype as they had already been predicted by the simulations. (orig.)

  17. Comprehensive Model of a Single-screw Expander for ORC-Systems

    Ziviani, Davide; Bell, Ian; van den Broek, Martijn; Paepe, Michel De


    The Organic Rankine Cycle (ORC) system is considered one of the leading technologies for waste heat recovery applications. In order to increase the overall efficiency, design improvements and optimization analyses are necessary. The expander is the key component to convert the thermal energy in useful work. Several volumetric and turbine expanders have been investigated. Among volumetric machines, scroll, twin-screw and vane-type expanders are the main technologies. Recently, a number of expe...

  18. Integrated Status and Effectiveness Monitoring Program - Entiat River Rotary Screw Traps, Snorkel Surveys, and Steelhead Redd Surveys, 2008-2009.

    Nelle, R.D.; Desgroseillier, Tom; Cotter, Michael [U.S. Fish and Wildlife Service


    The USFWS Mid-Columbia River Fishery Resource Office (MCRFRO) operated two rotary screw traps on the Entiat River as part of the Integrated Status and Effectiveness Monitoring Program from March through November of 2008. Along with the smolt traps, juvenile emigrants were also captured at remote locations throughout the Entiat watershed and its major tributary, the Mad River. A total of 16,782 wild salmonids were PIT tagged during the study period. Of this, 3,961(23.6%) were wild Oncorhynchus mykiss, 6,987 (41.6%) were wild spring run O. tshawytscha, and 5,591 (33.3%) were identified as wild O. tshawytscha of unknown run. Rotary screw trap efficiencies averaged 40.3% at the upper (Rkm 11.0) trap and 7.8% for the lower (Rkm 2.0) trap. These efficiencies were pooled for emigrant O. tshawytscha and O. mykiss. The MCRFRO conducted effectiveness monitoring snorkel surveys at 24 sites during the winter period and 30 sites during the summer and fall periods of 2008 as part of the Integrated Status and Effectiveness Monitoring Program in the Entiat River. The 2008 steelhead spawning grounds surveys were conducted weekly in the main Entiat River from rkm 1.1 to 44.2. A total of 222 steelhead redds were identified over the period from February 28 to June 16 2008 with April being the peak spawning month. Approximately 80% of the steelhead redds were located downstream of the rkm 26.

  19. Integrated Status and Effectiveness Monitoring Program - Entiat River Rotary Screw Traps,Snorkel Surveys, and Steelhead Redd Surveys, 2008.

    Nelle, R.D.; Desgroseiller, Tom; Cotter, Michael (U.S. Fish and Wildlife Service)


    The USFWS Mid-Columbia River Fishery Resource Office (MCRFRO) operated two rotary screw traps on the Entiat River as part of the Integrated Status and Effectiveness Monitoring Program from March through November of 2008. Along with the smolt traps, juvenile emigrants were also captured at remote locations throughout the Entiat watershed and its major tributary, the Mad River. A total of 16,782 wild salmonids were PIT tagged during the study period. Of this, 3,961(23.6%) were wild Oncorhynchus mykiss, 6,987 (41.6%) were wild spring run O. tshawytscha, and 5,591 (33.3%) were identified as wild O. tshawytscha of unknown run. Rotary screw trap efficiencies averaged 40.3% at the upper (Rkm 11.0) trap and 7.8% for the lower (Rkm 2.0) trap. These efficiencies were pooled for emigrant O. tshawytscha and O. mykiss. The MCRFRO conducted effectiveness monitoring snorkel surveys at 24 sites during the winter period and 30 sites during the summer and fall periods of 2008 as part of the Integrated Status and Effectiveness Monitoring Program in the Entiat River. The 2008 steelhead spawning grounds surveys were conducted weekly in the main Entiat River from rkm 1.1 to 44.2. A total of 222 steelhead redds were identified over the period from February 28 to June 16 2008 with April being the peak spawning month. Approximately 80% of the steelhead redds were located downstream of the rkm 26.

  20. Optimisation of two-stage screw expanders for waste heat recovery applications

    Read, M. G.; Smith, I. K.; Stosic, N.


    It has previously been shown that the use of two-phase screw expanders in power generation cycles can achieve an increase in the utilisation of available energy from a low temperature heat source when compared with more conventional single-phase turbines. However, screw expander efficiencies are more sensitive to expansion volume ratio than turbines, and this increases as the expander inlet vapour dryness fraction decreases. For singlestage screw machines with low inlet dryness, this can lead to under expansion of the working fluid and low isentropic efficiency for the expansion process. The performance of the cycle can potentially be improved by using a two-stage expander, consisting of a low pressure machine and a smaller high pressure machine connected in series. By expanding the working fluid over two stages, the built-in volume ratios of the two machines can be selected to provide a better match with the overall expansion process, thereby increasing efficiency for particular inlet and discharge conditions. The mass flow rate though both stages must however be matched, and the compromise between increasing efficiency and maximising power output must also be considered. This research uses a rigorous thermodynamic screw machine model to compare the performance of single and two-stage expanders over a range of operating conditions. The model allows optimisation of the required intermediate pressure in the two- stage expander, along with the rotational speed and built-in volume ratio of both screw machine stages. The results allow the two-stage machine to be fully specified in order to achieve maximum efficiency for a required power output.

  1. Influence of liquid in clearances on the operational behaviour of twin screw expanders

    Gräßer, Melanie; Brümmer, Andreas


    A lot of effort has been expended on understanding the influences of an injected auxiliary liquid on a twin screw expander's performance. Sealed clearances improve performance on the one hand, but involve considerable frictional losses on the other hand. This paper contributes to an evaluation of these opposing effects with regard to the efficiency of screw expanders. First, thermodynamic analyses using the multi-chamber model-based simulation tool KaSim, developed at the Chair of Fluidics, are presented for a test screw expander in order to show the maximum potential of clearance sealing. This analysis involves thermodynamic simulations for sealed and unsealed clearances and leads to an order of priorities for different clearance types. Second, hydraulic losses within front and housing clearances are calculated, applying an analytical model of incompressible one-phase clearance flow. Subsequently dry and wet screw expanders are evaluated while both clearance sealing and frictional losses are considered for the simulation of a liquid-injected machine.

  2. Comparison of Organic Rankine Cycle Under Varying Conditions Using Turbine and Twin-Screw Expanders

    Read, M. G.; Smith, I K; Stosic, N.


    A multi-variable optimization program has been developed to investigate the performance of Organic Rankine Cycles (ORCs) for low temperature heat recovery applications. This cycle model contains detailed thermodynamic models of the system components, and the methods used to match the operation of the expander to the requirements of the cycle are described. Two types of ORC system are considered; one containing a turbine to expand dry saturated or superheated vapour, and one with a twin-screw ...

  3. Performance Study on a Single-Screw Expander for a Small-Scale Pressure Recovery System

    Guoqiang Li


    Full Text Available A single-screw expander with 195 mm diameter is developed to recover pressure energy in letdown stations. An experiment system is established using compressed air as a working fluid instead of natural gas. Experiments are conducted via measurements for important parameters, such as inlet and outlet temperature and pressure, volume flow rate and power output. The influence of inlet pressure and rotational speed on the performance are also analyzed. Results indicate that the single-screw expander achieved good output characteristics, in which 2800 rpm is considered the best working speed. The maximum volumetric efficiency, isentropic efficiency, overall efficiency, and the lowest air-consumption are 51.1 kW, 83.5%, 66.4%, 62.2%, and 44.1 kg/(kW·h, respectively. If a single-screw expander is adopted in a pressure energy recovery system applied in a certain domestic natural gas letdown station, the isentropic efficiency of the single-screw expander and overall efficiency of the system are found to be 66.4% and 62.2%, respectively. Then the system performances are predicted, in which the lowest methane consumption is 27.3 kg/(kW·h. The installed capacity is estimated as 204.7 kW, and the annual power generation is 43.3 MWh. In the next stage, a pressure energy recovery demonstration project that recycles natural gas will be established within China, with the single-screw expander serving as the power machine.

  4. Functionality Evaluation of a Novel Smart Expandable Pedicle Screw to Mitigate Osteoporosis Effect in Bone Fixation: Modeling and Experimentation

    Ahmadreza Eshghinejad


    Full Text Available This paper proposes a novel expandable-retractable pedicle screw and analyzes its functionality. A specially designed pedicle screw is described which has the ability to expand and retract using nitinol elements. The screw is designed to expand in body temperature and retract by cooling the screw. This expansion-retraction function is verified in an experiment designed in larger scale using a nitinol antagonistic assembly. The results of this experiment are compared to the results of a finite element model developed in Abaqus in combination with a user material subroutine (UMAT. This code has been developed to analyze the nonlinear thermomechanical behavior of shape memory alloy materials. The functionality of the proposed screw is evaluated with simulation and experimentation in a pullout test as well. The pullout force of a normal screw inserted in a normal bone was simulated, and the result is compared with the results of the expandable screw in osteoporotic bone. Lastly, strength of the designed pedicle screw in a foam block is also verified with experiment. The reported finite element simulations and experiments are the proof for the concept of nitinol expandable-retractable elements on a pedicle screw which validate the functionality in a pullout test.

  5. Experimental Investigation of the Performance of a Hermetic Screw-Expander Organic Rankine Cycle

    Sung-Wei Hsu


    Full Text Available In this study, the authors experimentally investigate the performance of the organic Rankine cycle (ORC and screw expander under the influence of supply pressure and pressure ratio over the expander. Three tests were performed with expander pressure ratios of 2.4–3.5, 3.0–4.6, and 3.3–6.1, which cover the over-expansion and under-expansion operating modes. The test results show a maximum expander isentropic efficiency of 72.4% and a relative cycle efficiency of 10.5% at an evaporation temperature of 101 °C and condensation temperature of 45 °C. At a given pressure ratio over the expander, a higher supply pressure to the expander causes a higher expander isentropic efficiency and higher cycle efficiency in the over-expansion mode. However, in the under-expansion mode, the higher supply pressure results in a lower expander isentropic efficiency and adversely affects the cycle efficiency. The results also show that under the condition of operation at a given pressure ratio, a higher supply pressure yields a larger power output owing to the increased mass flow rate at the higher supply pressure. The study results demonstrate that a screw-expander ORC can be operated with a wide range of heat sources and heat sinks with satisfactory cycle efficiency.

  6. Update on single-screw expander geometry model integrated into an open-source simulation tool

    Ziviani, D.; Bell, I. H.; De Paepe, M.; van den Broek, M.


    In this paper, a mechanistic steady-state model of a single-screw expander is described with emphasis on the geometric description. Insights into the calculation of the main parameters and the definition of the groove profile are provided. Additionally, the adopted chamber model is discussed. The model has been implemented by means of the open-source software PDSim (Positive Displacement SIMulation), written in the Python language, and the solution algorithm is described. The single-screw expander model is validated with a set of steady-state measurement points collected from a 11 kWe organic Rankine cycle test-rig with SES36 and R245fa as working fluid. The overall performance and behavior of the expander are also further analyzed.

  7. Thermodynamic Simulation on the Performance of Twin Screw Expander Applied in Geothermal Power Generation

    Yuanqu Qi; Yuefeng Yu


    A three-dimensional (3D) geometry model of twin screw expander has been developed in this paper to measure and analyze geometric parameters such as groove volume, suction port area, and leakage area, which can be described as functions of rotation angle of male rotor. Taking the suction loss, leakage loss, and real gas effect into consideration, a thermodynamic model is developed using continuity and energy conservation equation. The developed model is verified by comparing predicted results ...

  8. Multi-Variable Optimisation Of Wet Vapour Organic Rankine Cycles With Twin-Screw Expanders


    A multi-variable optimisation program has been developed to investigate the performance of Wet Organic Rankine Cycles for low temperature heat recovery applications. This cycle model contains a detailed thermodynamic model of the twin-screw expander, and the methods used to match the operation of the expander to the requirements of the cycle are described. The capability of the cycle model has been demonstrated for the case of heat recovery from a source of pressurized hot water at 120°C. The...

  9. Thermodynamic Simulation on the Performance of Twin Screw Expander Applied in Geothermal Power Generation

    Yuanqu Qi


    Full Text Available A three-dimensional (3D geometry model of twin screw expander has been developed in this paper to measure and analyze geometric parameters such as groove volume, suction port area, and leakage area, which can be described as functions of rotation angle of male rotor. Taking the suction loss, leakage loss, and real gas effect into consideration, a thermodynamic model is developed using continuity and energy conservation equation. The developed model is verified by comparing predicted results of power output and internal efficiency with experimental data. Based on the model, the relationship between mass flow rate through inlet port and leakage path with rotation angle of male rotor as well as effects of the inlet parameter and operating parameter on the performance of the expander are analyzed.

  10. International test and demonstration of a 1-MW wellhead generator: Helical screw expander power plant

    McKay, R. A.


    A 1-MW wellhead generator was tested in 1980, 1981, and 1982 by Mexico, Italy, and New Zealand at Cerro Prieto, Cesano, and Broadlands, respectively. The total flow helical screw expander portable power plant, Model 76-1, had been built for the U.S. Government and field-tested in Utah, USA, in 1978 and 1979. The expander had oversized internal clearances designed for self-cleaning operation on fluids that deposit adherent scale normally detrimental to the utiliation of liquid dominated fields. Conditions with which the expander was tested included inlet pressures of 64 to 220 psia, inlet qualities of 0% to 100%, exhaust pressures of 3.1 to 40 psia, electrial loads of idle and 110 to 933 kW, electrical frequencies of 50 and 60 Hz, male rotor speeds of 2500 to 4000 rpm, and fluid characteristics to 310,000 ppm total dissolved solids and noncondensables to 38 wt % of the vapor. Some testing was done on-grid. Typical expander isentropic efficiency was 40% to 50% with the clearances not closed, and 5 percentage points or more higher with the clearances partly closed. The expander efficiency increased approximately logarithmically with shaft power for most operations, while inlet quality, speed, and pressure ratio across the machine had only small effects. These findings are all in agreement with the Utah test results.

  11. 连续回转式拧盖机的创新设计%The Innovative Design for the Continuous Rotary Cap Screwing Machine



    According to the turning around of the cap screwing head in continuous rotary cap screwing machine, analyze the relationship between rotation movement, revolution movement, up and down movement of cap screwing head; Combining the main structure of the machine, summarize the key factor of the quality of cap screwing. Put forward a way of innovation design which is the process of production defines the principle of the transmission, the mode of cap fixing effects the machine' s structure.%根据连续回转式拧盖机中拧盖头公转一周的工艺过程,分析了拧盖头的自转运动、公转运动、上下往复运动之间相互关系;并结合拧盖机的主要结构,总结了影响拧盖质量的关键因素.提出了"工艺过程决定拧盖机的传动原理,瓶盖结构决定拧盖机的结构参数"的创新设计方法.

  12. Surgically assisted rapid palatal expansion with tent screws and a custom-made palatal expander: a case report.

    Park, Kang-Nam; Lee, Chang Youn; Park, In Young; Kim, Jwa Young; Yang, Byoungeun


    Rapid palatal expansion(RPE) with the tooth-born appliance is not sufficient to apply to the patients with periodontal problem or insufficient tooth anchorage, and it leads to tipping of the anchorage teeth and increasing teeth mobility and root resorption. To avoid these disadvantages, we present the case using palatal screws and custommade palatal expander. A 23-year-old patient underwent surgically assisted rapid maxillary expansion with the Hyrax expansion using 4 tent screws. The study models were used to measure the pre-/-post surgical width of the anterior and posterior dental arches with a digital sliding caliper. In the result, the custom-made palatal expander with 4 tent screws is suitable for delivering a force to the mid-palatal suture expansion. And it is low cost, small sized and simply applied. The results indicated that maxillary expansion with the custom-made palatal anchorage device is predictable and stable technique without significant complications in patients.

  13. Enumeration of Juvenile Salmonids in the Okanogan Basin Using Rotary Screw Traps, Performance Period: March 15, 2006 - July 15, 2006.

    Johnson, Peter N.; Rayton, Michael D.


    The Colville Tribes identified the need for collecting baseline census data on the timing and abundance of juvenile salmonids in the Okanogan River basin for the purpose of documenting local fish populations, augmenting existing fishery data and assessing natural production trends of salmonids. This report documents and assesses the pilot year of rotary trap capture of salmonid smolts on the Okanogan River. The project is a component of the Colville Tribes Okanogan Basin Monitoring and Evaluation Program (OBMEP) which began in 2004. Trapping for outmigrating fish began on 14 March 2006 and continued through 11 July 2006. Anadromous forms of Oncorhynchus, including summer steelhead (O. mykiss), Chinook (O. tshawytscha), and sockeye (O. nerka), were targeted for this study; all have verified, natural production in the Okanogan basin. Both 8-ft and 5-ft rotary screw traps were deployed on the Okanogan River from the Highway 20 Bridge and typically fished during evening hours or 24 hours per day, depending upon trap position and discharge conditions. Juvenile Chinook salmon were the most abundant species trapped in 2006 (10,682 fry and 2,024 smolts), followed by sockeye (205 parr and 3,291 smolts) and steelhead (1 fry and 333 smolts). Of the trapped Chinook, all fry were wild origin and all but five of the smolts were hatchery-reared. All trapped sockeye were wild origin and 88% of the steelhead smolts were hatchery-reared. Mark-recapture experiments were conducted using Chinook fry and hatchery-reared steelhead smolts (sockeye were not used in 2006 because the peak of the juvenile migration occurred prior to the onset of the mark-recapture experiments). A total of 930 chinook fry were marked and released across eight separate release dates (numbers of marked Chinook fry released per day ranged from 34 to 290 fish). A total of 11 chinook fry were recaptured for an overall trap efficiency of 1.18%. A total of 710 hatchery-reared steelhead were marked and released across

  14. Slide Valves for Single-Screw Expanders Working Under Varied Operating Conditions

    Yuting Wu


    Full Text Available This paper fully describes the working principle of slide valves in single-screw expanders (SSEs. A geometric analysis of suction and volume ratio slide valves is presented to determine the relations between volume ratio, suction closure volume, discharge opening volume and slide valves displacement. An organic Rankine cycle (ORC thermodynamic model with SSE integrated with slide valves is developed to analyze the power output of SSE and the net power output of ORC system and variation law of slide valves displacement. Analysis of a typical ORC system under changing operating conditions shows that the power output of the expander and the net output power of the ORC system with slide valves are much better than those without slide valves. When the condensing temperature is 40 °C and the waste availability is 80 kW, the increase in output power and net output power are approximately 3.4 kW and 5 kW, respectively. The presented geometric analysis of slide valves and the thermodynamic model integrated with slide valves can be used to provide a theoretical and technical basis for designing the slide valves of SSEs and the control strategies of slide valves under varied operating conditions.

  15. Performance Analysis of the Vehicle Diesel Engine-ORC Combined System Based on a Screw Expander

    Kai Yang


    Full Text Available To achieve energy saving and emission reduction for vehicle diesel engines, the organic Rankine cycle (ORC was employed to recover waste heat from vehicle diesel engines, R245fa was used as ORC working fluid, and the resulting vehicle diesel engine-ORC combined system was presented. The variation law of engine exhaust energy rate under various operating conditions was obtained, and the running performances of the screw expander were introduced. Based on thermodynamic models and theoretical calculations, the running performance of the vehicle diesel engine-ORC combined system was analyzed under various engine operating condition scenarios. Four evaluation indexes were defined: engine thermal efficiency increasing ratio (ETEIR, waste heat recovery efficiency (WHRE, brake specific fuel consumption (BSFC of the combined system, and improvement ratio of BSFC (IRBSFC. Results showed that when the diesel engine speed is 2200 r/min and diesel engine torque is 1200 N·m, the power output of the combined system reaches its maximum of approximately 308.6 kW, which is 28.6 kW higher than that of the diesel engine. ETEIR, WHRE, and IRBSFC all reach their maxima at 10.25%, 9.90%, and 9.30%, respectively. Compared with that of the diesel engine, the BSFC of the combined system is obviously improved under various engine operating conditions.

  16. Designing of monitoring setup for vibration signature analysis of steam turbine driven high capacity rotary screw compressor

    Pyne, T.; Vinod, J. [Birla VXL Ltd., Porbandar (India)


    Tracking the behaviour by signature analysis of machines like Screw Compressor having large number of auxiliaries, high power transmissions, variation of process gas properties, changes of load condition, fluctuating revolutions is truly a challenging job. These unavoidable process conditions often disturb the whole setup and there is every possibility to miss important and relevant information. Standards for overall monitoring as well as for peak-amplitudes responsible for root cause identification are not always available because these machines are `custom designed` and manufacturer`s standards are of paramount importance to consider. The health of these machines cannot be assessed by simply comparing with the international standards unlike most common machines such as fans, pumps, motors etc. with minimum number of auxiliaries. There may also be limitations in the features of the instruments used for the purpose. In this presentation, an attempt has been made to setup a monitoring approach for screw compressor which will help the industries initially setting base-line data to implement vibration analysis based off-line predictive maintenance programme either with the help of an analyser or with a latest software. (orig.) 3 refs.

  17. Pull-out strength comparison of a novel expanding fastener against an orthopaedic screw in an ovine vertebral body: an ex-vivo study.

    Oldakowski, Matthew; Oldakowska, Intan; Kirk, Thomas B; Ford, Chris T; Sercombe, Tim B; Hardcastle, Philip; Day, Robert E


    The purpose of this study was to mechanically test a novel Unthreaded Expandable Fastener (UEF), manufactured using Selective Laser Melting, which was designed for fixation in the cervical lateral mass. The pull-out strength and stiffness of the prototype UEFs was evaluated in a non-osteoporotic ovine bone model against equivalent screws. The prototype UEF demonstrated a 41% increase in failure force and a 60% reduction in failure force standard deviation compared to the screws. All bone samples were micro CT-scanned and no significant differences in bone microstructural properties was found between the screw and UEF sample sets, indicating that the UEFs may be less sensitive to bone quality variation. This increased performance can potentially translate into improved surgical outcome and reduced surgical risk for lateral mass fixation. With further design optimisation, additional improvement in performance over screws may be possible in future studies.

  18. Effect of twin-screw extrusion parameters on mechanical hardness of direct-expanded extrudates

    M Brnčić; B Tripalo; D Ježek; D Semenski; N Drvar; M Ukrainczyk


    Mechanical properties of cereal (starch-based) extrudates are perceived by the final consumer as criteria of quality. We investigate one of the important characteristics of extrudates, mechanical hardness, which is one of the main texture parameters. Texture quality has an influence on taste sensory evaluation, and thus on the acceptability of the product. Characteristics that have great influence on acceptability are crispness, elasticity, hardness and softness. These attributes are narrowly related to, and affected by, the process parameters. A 2-level–4-factor factorial experimental design was used to investigate the influence of temperature of expansion, screw speed, feed moisture content and feed rate, and their interactions, on the mechanical hardness of extrudates. Feed moisture content, screw speed and temperature are found to influence, while feed rate does not have significant effect on extrudate hardness. Mechanical properties of specimens were measured by means of compression testing, based on the concept of nominal stress, using a universal testing machine and special grips that were constructed for this purpose.

  19. Performance study on three-stage power system of compressed air vehicle based on single-screw expander


    A new compressed-air engine system based on three-stage single screw expander was proposed to improve the performance of power system.Three different structure styles were presented,and the studies on the power performance and the distribution of expansion ratios between stages were carried out by programming and mathematical modeling of each style.Research results indicated that the best matches of expansion ratios with equal heat temperature for the air tank of pressure 30 MPa were seven-five-three for"first-stage heating"style,eight-five-three for"two-stage heating"style and five-five-four for"three-stage heating"style,respectively.Results also showed that heating up inlet air or increasing the expander efficiency might improve the power performance.The output power of the"two-stage heating"style is far higher than that of"first-stage heating"style and is a little lower than that of"three-stage heating"style.The new system showed good structure and power performances.

  20. Numerical and Experimental Investigation of Pressure Losses at Suction of a Twin Screw Compressor

    Arjeneh, M.; Kovacevic, A.; Rane, S.; Manolis, M.; Stosic, N.


    Rotary twin screw machines are used in the wide range of industrial applications and are capable of handling single and multiphase fluids as compressors, expanders and pumps. Concentration of liquid in the inlet flow can influence the performance of the machine significantly. Characteristics of the multiphase flow at the suction of a screw compressor depend on the local flow velocities and concentration. Local flow velocity measurements inside the screw compressors are difficult to obtain. However other flow properties such as local pressures are easier to attain. It is therefore useful to carry out experiments with local pressure variations in the suction which can be used to validate the 3D numerical Computational Fluid Dynamic (CFD) models that could help in studying the single and multiphase flow behaviour in screw compressors. This paper presents experimental efforts to measure the local pressure losses inside the suction plenum of the screw compressor. Pressure variations are measured at 23 locations in the suction port at various operating conditions and compared with 3D CFD model. The grid generator SCORGTM was used for generating numerical mesh of rotors. The flow calculations were carried out using commercial 3D solver ANSYS CFX. It was found that the local pressure changes predicted by the CFD model are in the good agreement with measured pressures. This validated the use of CFD for modelling of the single phase flows in suction of screw machines.

  1. A Novel Vapor Injection Structure on the Blade for Rotary Compressor

    Wang, Baolong; Liu, Xingru; Shi, Wenxing


    Rotary compressors have been extensively used in room air conditioners and household refrigerators for their advantages, including high efficiency, strong adaptability, and low cost. However, when air source heat pumps with rotary compressors are applied in cold regions, a series of problems appear. The gas injection has been proved an effective technology to enhance both the heating capacity and COP of scroll, screw, and rotary compressors. In the one-cylinder rotary compressor with gas in...

  2. Bony healing of unstable thoracolumbar burst fractures in the elderly using percutaneously applied titanium mesh cages and a transpedicular fixation system with expandable screws.

    Anica Eschler

    Full Text Available There is a high incidence of vertebral burst fractures following low velocity trauma in the elderly. Treatment of unstable vertebral burst fractures using the same principles like in stable vertebral burst fractures may show less favourable results in terms of fracture reduction, maintenance of reduction and cement leakage. In order to address these shortcomings this study introduces cementless fixation of unstable vertebral burst fractures using internal fixators and expandable intravertebral titanium mesh cages in a one-stage procedure via minimum-invasive techniques.A total of 16 consecutive patients (median age 76 years, range 58-94 with unstable thoracolumbar burst fractures and concomitant osteoporosis were treated by an internal fixator inserted via minimum invasive technique one level above and below the fractured vertebra. Fracture reduction was achieved and maintained by transpedicular placement of two titanium mesh cages into the fractured vertebral body during the same procedure. Intra- and postoperative safety of the procedure as well as analysis of reduction quality was analysed by 3D C-arm imaging or CT, respectively. Clinical and radiographic follow-up averaged 10.4 months (range 4.5-24.5.Stabilization of the collapsed vertebral body was achieved in all 16 cases without any intraoperative complication. Surgical time averaged 102 ± 6.6 minutes (71-194. The postoperative kyphotic angle (KA and Cobb angle revealed significant improvements (KA 13.7° to 7.4°, p < 0.001; Cobb 9.6° to 6.0°, p < 0.002 with partial loss of reduction at final follow-up (KA 8.3°, Cobb 8.7°. VAS (Visual Analogue Scale improved from 7.6 to 2.6 (p < 0.001. Adjacent fractures were not observed. One minor (malposition of pedicle screw complication was encountered.Cementless fixation of osteoporotic burst fractures revealed substantial pain relief, adequate maintenance of reduction and a low complication rate. Bony healing after unstable osteoporotic burst

  3. Rotary Transformer

    McLyman, Colonel Wm. T.


    None given. From first Par: Many spacecraft (S/C) and surface rovers require the transfer of signals and power across rotating interfaces. Science instruments, antennas and solar arrays are elements needing rotary power transfer for certain (S/C) configurations. Delivery of signal and power has mainly been done by using the simplest means, the slip ring approach. This approach, although simple, leaves debris generating noise over a period of time...The rotary transformer is a good alternative to slip rings for signal and power transfer.

  4. Rotary ATPases

    Stewart, Alastair G.; Sobti, Meghna; Harvey, Richard P.; Stock, Daniela


    Rotary ATPases are molecular rotary motors involved in biological energy conversion. They either synthesize or hydrolyze the universal biological energy carrier adenosine triphosphate. Recent work has elucidated the general architecture and subunit compositions of all three sub-types of rotary ATPases. Composite models of the intact F-, V- and A-type ATPases have been constructed by fitting high-resolution X-ray structures of individual subunits or sub-complexes into low-resolution electron densities of the intact enzymes derived from electron cryo-microscopy. Electron cryo-tomography has provided new insights into the supra-molecular arrangement of eukaryotic ATP synthases within mitochondria and mass-spectrometry has started to identify specifically bound lipids presumed to be essential for function. Taken together these molecular snapshots show that nano-scale rotary engines have much in common with basic design principles of man made machines from the function of individual “machine elements” to the requirement of the right “fuel” and “oil” for different types of motors. PMID:23369889

  5. Rotary capacitor


    The rotating wheel of the rotary capacitor representing the most critical part of the new radio-frequency system of the synchro-cyclotron. The three rows of teeth on the circumference of the wheel pass between four rows of stator blades with a minimum clearance of 1 mm at a velocity of 1700 rev/min.

  6. 股骨颈膨胀式带锁加压钉的研制及生物力学评价%Development and biomechanical evaluation of interlocking expanding compressive screws for femoral neck fracture

    黄彰; 苏家庆; 吴冬雷; 梅宝珊; 谢杰


    目的探讨股骨颈骨折内固定的方法,评价 HZS型股骨颈膨胀式带锁加压钉( interlocking expanding compressive screw, IECS)的生物力学性能.方法根据股骨颈骨折特殊的生物力学特性,设计制作由主钉、股骨头分叉钉、分叉钉推进螺帽、加压螺帽匀力垫、加压螺帽、斜向锁钉和主钉尾帽构成的股骨颈膨胀式带锁加压钉,以单枚双头加压螺钉( dynamic compressive screw, DCS)、双头加压子母螺钉( twin compressive screw, 2CS)和三枚空心加压螺钉( three cannulated screws, 3CS)作对照组进行生物力学实验.结果 IECS固定的股骨颈骨折在位移、轴向和水平剪切刚度、扭转强度和刚度、极限载荷等生物力学性能均明显优越于 DCS、 2CS和 3CS.结论 IECS能有效对抗骨折断端间的分离、扭转、剪切、张应力和压应力.结构轻巧,操作简便,安全可靠.

  7. Study of low elastic modulus expandable screws in osteoporotic sheep in vivo%低弹性模量膨胀螺钉在骨质疏松绵羊的体内研究

    石磊; 王陵; 雷伟; 郭征; 吴子祥; 刘达


    Objective To observe the biological performance of the low elastic modulus expandable screw in osteoporotic sheep in vivo and to find out whether the stability of the screw can be improved. Methods Four adult female sheep were ovariectomized. After 12 months, the bone mineral density of the lumber vertebra was determined using dual energy X-ray absorptiometry to confirm the establishment of the osteoporosis model. Bilateral pedicles of the lumbar vertebrae ( L, -L, ) were random fixed with two different elastic modulus expendable screws, low elastic module expandable screws (42GPa) for the experiment group and ordinary expandable screws (HOGPa) for the control group. All the animals were sacrificed 3 months after the implantation. Maximal force testing, micro-CT measurement, and histology analysis were performed. Results BMD of the lumbar vertebrae of the sheep decreased significantly 1 year after ovariectomy ( P 0. 05 ) . Histological observation showed that newly formed bone around the screws was more in the experimental group than in the controlgroup. Meanwhile more tight contact and less fibrous connective tissue were observed on the screw-boneinterface in the experimental group. Conclusion The low elastic modulus expandable screws can furtherimprove the biomechanioal fixation strength in osteoporotk: sheep and reduce the failure of the screwfixation, through reduction of the difference of elastic modulus between the screws and the surrounding bonetissue.%目的 观察应力作用下低弹性模量膨胀螺钉在骨质疏松绵羊体内生物学表现,探讨其是否能在普通膨胀螺钉的基础上进一步提高螺钉的稳定性.方法 选用4只成年雌性绵羊,行去势手术12月后,以双能X线骨密度测量仪测定去势前后腰椎骨密度,确定骨质疏松模型建立成功.于L1-L5脊椎两侧椎弓根内随机植入两种弹性模量的膨胀螺钉,低弹膨胀螺钉(42GPa)为实验组,普通膨胀螺钉(110GPa)为对照组,术后3月处

  8. Formation of technical requirements for flexible rotary machine nodes

    Bulenkov, Y.; Mikhaylov, A.


    The method of parameters determining for the flexible rotary machines and lines and its individual components is described in this article. The method is based on the analysis of the fail safe performance probability. It allows determining the fail safe performance probability for tools, transportation and tool changing device nodes, elements of flexible rotary machine and is based on the analysis of flexible rotor line structure. The relationships between rational flexible rotary line structure and parameters of the individual nodes are shown on the flexible rotor line for the screws processing.

  9. Experimentally based characteristics model for performance mapping of dry-running helical screw expanders in closed-cycle applications. Experimentell gestuetztes Kennzahlmodell zur Beschreibung des Betriebsverhaltens trockenlaufender Schrauben-Expansionsmaschinen in Kreisprozessen

    Hinsenkamp, G. (Lehrstuhl und Institut fuer Thermische Stroemungsmaschinen, Univ. Karlsruhe (Germany)); Willibald, U. (Steinmueller (L. und C.) GmbH, Gummersbach (Germany)); Wittig, S. (Lehrstuhl und Institut fuer Thermische Stroemungsmaschinen, Univ. Karlsruhe (Germany))


    Earlier investigations at the Institute for Thermal Turbomachinery (University of Karlsruhe) have shown favorable operating characteristics of positive-displacement type prime movers in the range of low power output. The main goal of this study is the development of a new parameter model which characterizes dry-running helical screw-expanders. This model is derived by use of dimensional analysis. It is therefore independent from absolute values of machine size and process boundary conditions. As a special feature of the chosen model, all loss-describing specific work parameters at a constant circumferential Mach number are shown to be straight lines. Therefore, the specification of only two operating points is sufficient to carry out a quantitative loss analysis for design and off-design conditions of any characteristic line. For the first time, the presented model provides for the calculation and extrapolation of generalized volumetric and isentropic efficiencies. Finally, the documented analysis technique may readily be applied to other types of positive displacement expanders and -compressors by modifying the presented parameters accordingly. (orig./HW)

  10. Study on the Performance of Twin-screw Expander-compressor Used for Seawater Desalination%用于海水淡化的双螺杆膨胀压缩机热力性能研究

    张凯; 高磊; 董冰; 邢子文


    为了研究用于机械压汽海水淡化系统的双螺杆蒸汽膨胀压缩机热力性能,建立了压缩机和膨胀机热力模型。根据已知参数求解压缩机喷水量和轴功率,膨胀机进气温度和质量流量,将计算结果与热力压汽淡化系统进行比较。通过改变压缩机进、排气压力和膨胀机进气压力,对膨胀压缩机进行变工况性能分析。结果显示,压缩机进、排气压力会对压缩机喷水量和轴功率产生不同影响;膨胀机进气压力决定进气温度的高低,且存在最佳值。%In order to study the thermal performance of twin-screw expander-compressor used for mechanical vapor compression seawater desalination system,the thermodynamic model of compressor and expander are built. Parameters like water spray mass flow rate and shaft power of the compressor,intake temperature and mass flow rate of the expander are calculated based on the known conditions,then the results are compared with thermal vapor compression seawater desalination system. Different compres-sor intake,exhaust pressure and expander intake pressure were chosen to analyze the variable condition performance of expander-compressor. The results show that the intake and exhaust pressure have different effects on shaft power and water spray mass rate of compressor;the intake pressure of the expander decides the intake temperature,and there exists an optimum value.

  11. Methods for Expanding Rotary Wing Aircraft Health and Usage Monitoring Systems to the Rotating Frame through Real-time Rotor Blade Kinematics Estimation

    Allred, Charles Jefferson

    Since the advent of Health and Usage Monitoring Systems (HUMS) in the early 1990's, there has been a steady decrease in the number of component failure related helicopter accidents. Additionally, measurable cost benefits due to improved maintenance practices based on HUMS data has led to a desire to expand HUMS from its traditional area of helicopter drive train monitoring. One of the areas of greatest interest for this expansion of HUMS is monitoring of the helicopter rotor head loads. Studies of rotor head load and blade motions have primarily focused on wind tunnel testing with technology which would not be applicable for production helicopter HUMS deployment, or measuring bending along the blade, rather than where it is attached to the rotor head and the location through which all the helicopter loads pass. This dissertation details research into finding methods for real time methods of estimating rotor blade motion which could be applied across helicopter fleets as an expansion of current HUMS technology. First, there is a brief exploration of supporting technologies which will be crucial in enabling the expansion of HUMS from the fuselage of helicopters to the rotor head: wireless data transmission and energy harvesting. A brief overview of the commercially available low power wireless technology selected for this research is presented. The development of a relatively high-powered energy harvester specific to the motion of helicopter rotor blades is presented and two different prototypes of the device are shown. Following the overview of supporting technologies, two novel methods of monitoring rotor blade motion in real time are developed. The first method employs linear displacement sensors embedded in the elastomer layers of a high-capacity laminate bearing of the type commonly used in fully articulated rotors throughout the helicopter industry. The configuration of these displacement sensors allows modeling of the sensing system as a robotic parallel

  12. Rotary filtration system

    Herman, David T.; Maxwell, David N.


    A rotary filtration apparatus for filtering a feed fluid into permeate is provided. The rotary filtration apparatus includes a container that has a feed fluid inlet. A shaft is at least partially disposed in the container and has a passageway for the transport of permeate. A disk stack made of a plurality of filtration disks is mounted onto the shaft so that rotation of the shaft causes rotation of the filtration disks. The filtration disks may be made of steel components and may be welded together. The shaft may penetrate a filtering section of the container at a single location. The rotary filtration apparatus may also incorporate a bellows seal to prevent leakage along the shaft, and an around the shaft union rotary joint to allow for removal of permeate. Various components of the rotary filtration apparatus may be removed as a single assembly.

  13. Engine Waste Heat Recovery Based on Single Screw Expander%基于单螺杆膨胀机的发动机排气余热回收系统

    张红光; 刘彬; 陈研; 杨凯; 张健; 王东芳


    针对发动机排气余热的特点,设计了有机朗肯循环(ORC)排气余热回收系统,采用单螺杆膨胀机作为动力输出装置,采用R245fa作为工质,提出了发动机排气余热利用率的概念和计算方法.结合发动机的试验数据,分析了ORC工质蒸发压力和发动机转速对ORC系统性能的影响,确定了适用于ORC系统的工质蒸发压力的最佳值.研究结果表明,当工质蒸发压力为3.0 MPa时,ORC系统能够在发动机全转速范围内正常工作,并且ORC系统的净输出功率最高可达12.1 kW,热力学第一定律效率最高可达11.27%,热力学第二定律效率最高可达25.8%,发动机排气余热利用率最高可达8.9%,发动机排气余热回收效果明显.%In order to make better use of waste heat energy from engine exhaust gas, the waste heat recovery system based on organic Rankine cycle (ORC) was presented, a single screw expander was used as the power output device, R245fa was used as working fluid, the concept and calculating method of waste heat recovery utilization rate was introduced. On the basis of engine test results, the effects of working fluid evaporating pressure and engine speed on the ORC system performance were analyzed and discussed, and then the optimal value of working fluid evaporating pressure was selected. According to the research results, when the working fluid evaporating pressure is 3.0 MPa, ORC waste heat recovery system can work properly over the whole range of engine speed, the maximum of net power is 12. 1 kW, the maximum of first law efficiency is 11.27% , the maximum of second law efficiency is 25.8% , the maximum of waste heat recovery utilization rate is 8. 9% , waste heat energy from engine exhaust gas can be recovered effectively.

  14. The Influence of the Heat Source Temperature on the Multivane Expander Output Power in an Organic Rankine Cycle (ORC System

    Piotr Kolasiński


    Full Text Available Organic Rankine Cycle (ORC power systems are nowadays an option for local and domestic cogeneration of heat and electric power. Very interesting are micropower systems for heat recovery from low potential (40–90 °C waste and renewable heat sources. Designing an ORC system dedicated to heat recovery from such a source is very difficult. Most important problems are connected with the selection of a suitable expander. Volumetric machines, such as scroll and screw expanders, are adopted as turbine alternative in small-power ORC systems. However, these machines are complicated and expensive. Vane expanders on the other hand are simple and cheap. This paper presents a theoretical and experimental analysis of the operation of a micro-ORC rotary vane expander under variable heat source temperature conditions. The main objective of this research was therefore a comprehensive analysis of relation between the vane expander output power and the heat source temperature. A series of experiments was performed using the micropower ORC test-stand. Results of these experiments are presented here, together with a mathematical description of multivane expanders. The analysis presented in this paper indicates that the output power of multivane expanders depend on the heat source temperature, and that multivane expanders are cheap alternatives to other expanders proposed for micropower ORC systems.

  15. A miniature Rotary Compressor with a 1:10 compression ratio

    Dmitriev, Olly; Tabota, Eugene; Arbon EurIng, Ian; FIMechE, CEng


    Micro compressors have applications in medical devices, robotics and “nanosatellites”. The problem of active cooling for photo detectors in “nano-satellites” becomes more important because the majority of space missions target Earth observation, and passive cooling does not provide the required temperatures to achieve the desired SNR levels. Reciprocating compressors used in cryocoolers cause vibrations. VERT Rotors has built an ultralow-vibration rotary compressor with 40mm-long screws, and our prototype delivered 1:10 compression ratio. This “nano” compressor is a non-conventional conical type consisting of an Inner conical screw rotor revolving inside an Outer screw rotor.

  16. Effect of expandable pedicle screw fixation on the fixation strength of osteoporotic thoracic and lumbar vertebrae%可膨胀椎弓根钉骨水泥强化与骨质疏松性胸腰椎固定强度的关系

    周庆忠; 冯晓兰; 张戈; 贾叙锋; 雷飞; 叶飞; 冯大雄


    背景:研究表明,骨质疏松常导致椎弓根螺钉内固定失败.采用普通椎弓根螺钉固定骨质疏松椎体达不到坚强的稳定性,需要采取特殊强化措施.目的:评价骨水泥强化联合可膨胀椎弓根螺钉对骨质疏松性胸腰椎稳定性的影响.方法:将20个骨质疏松性人胸腰椎椎体标本随机分为4组,普通椎弓根钉组置入普通椎弓根螺钉,其余3组均置入可膨胀椎弓根螺钉;可膨胀椎弓根钉组不进行骨水泥强化,聚甲基丙烯酸甲酯骨水泥强化组及硫酸钙骨水泥强化组于钉道内分别注入聚甲基丙烯酸甲酯骨水泥及硫酸钙骨水泥之后再置入可膨胀椎弓根钉.选择一侧椎弓根,测试椎弓根螺钉的最大轴向拔出力及屈服能量吸收值(对螺钉的握力);选择另一侧椎弓根,测试最大旋出力矩;并观察骨水泥强化后的骨水泥渗漏情况.结果与结论:①与普通椎弓根钉组相比,其余3组的最大轴向拔出力、最大旋出力矩及屈服能量吸收值均显著增加(P0.05);②骨水泥强化后未发生骨水泥渗漏现象;③结果表明,骨水泥强化联合可膨胀椎弓根螺钉可显著增强骨质疏松胸腰椎椎体的稳定性,聚甲基丙烯酸甲酯骨水泥与硫酸钙骨水泥效果相似.%BACKGROUND: Studies have shown that osteoporosis often leads to a failure in pedicle screw fixation. Considering that the use of ordinary pedicle screw fixation cannot achieve a strong and stable fixation of the osteoporotic vertebra,special measures to strengthen the internal fixation is indispensable.OBJECTIVE: To evaluate the effect of bone cement augmentation combined with expandable pedicle screw fixation on the fixation strength of osteoporotic thoracolumbar vertebrae.METHODS: Twenty osteoporotic thoracolumbar vertebral specimens were randomly divided into four groups: conventional pedicle screw group implanted with normal pedicle screw, and the other three groups implanted with expandable

  17. Properties of extruded expandable breadfruit products

    Dried breadfruit was extruded with a twin screw extruder to develop a value-added expanded fruit product. This research studied the effects of barrel temperature (120-160°C), moisture content (13-25%), feeding rate (13-25 kg/h) and screw speed (115-175rpm) on physicochemical properties (bulk densit...

  18. An Improved Rotary Mechanism Engine

    M.L Kumar


    Full Text Available Developments in the field of rotary engines have been reviewed. Potential of scissor action type rotary engine with suitable innovations on linkage and multirotor configuration has been brought out.

  19. Smart hybrid rotary damper

    Yang, C. S. Walter; DesRoches, Reginald


    This paper develops a smart hybrid rotary damper using a re-centering smart shape memory alloy (SMA) material as well as conventional energy-dissipating metallic plates that are easy to be replaced. The ends of the SMA and steel plates are inserted in the hinge. When the damper rotates, all the plates bend, providing energy dissipating and recentering characteristics. Such smart hybrid rotary dampers can be installed in structures to mitigate structural responses and to re-center automatically. The damaged energy-dissipating plates can be easily replaced promptly after an external excitation, reducing repair time and costs. An OpenSEES model of a smart hybrid rotary was established and calibrated to reproduce the realistic behavior measured from a full-scale experimental test. Furthermore, the seismic performance of a 3-story moment resisting model building with smart hybrid rotary dampers designed for downtown Los Angeles was also evaluated in the OpenSEES structural analysis software. Such a smart moment resisting frame exhibits perfect residual roof displacement, 0.006", extremely smaller than 18.04" for the conventional moment resisting frame subjected to a 2500 year return period ground motion for the downtown LA area (an amplified factor of 1.15 on Kobe earthquake). The smart hybrid rotary dampers are also applied into an eccentric braced steel frame, which combines a moment frame system and a bracing system. The results illustrate that adding smart hybrid rotaries in this braced system not only completely restores the building after an external excitation, but also significantly reduces peak interstory drifts.

  20. Rotary mechanical latch

    Spletzer, Barry L.; Martinez, Michael A.; Marron, Lisa C.


    A rotary mechanical latch for positive latching and unlatching of a rotary device with a latchable rotating assembly having a latching gear that can be driven to latched and unlatched states by a drive mechanism such as an electric motor. A cam arm affixed to the latching gear interfaces with leading and trailing latch cams affixed to a flange within the drive mechanism. The interaction of the cam arm with leading and trailing latch cams prevents rotation of the rotating assembly by external forces such as those due to vibration or tampering.

  1. Schlumberger downhole innovations applied at Hibernia : powerdrive rotary steerable systems

    Wilkie, P. [Schlumberger Canada Ltd., Calgary, AB (Canada)


    This presentation described the benefits of using a powerdrive rotary steerable system on the Hibernia offshore drilling platform compared to conventional motor directional drilling. New developments have expanded the operating envelope of rotary steerable services. The powerdrive rotary steerable system has mud actuated pads with fully rotating external parts. This presentation included a series of schematics depicting the control unit; the bias unit and mud flow; and, the drive mechanism. The benefits of the rotary steerable system compared to conventional motors include enhanced performance, better hole quality, less wellbore tortuosity, better hole cleaning, and extra power drive. Graphs depicting the history of power drive performance at Hibernia were included. Greater power drive offers increased drilling footage per year, a smoother well profile, and the ability to hit small targets. Greater power drive also enables extended reach platform wells versus subsea tie-backs. figs.

  2. Compressive Force With 2-Screw and 3-Screw Subtalar Joint Arthrodesis With Headless Compression Screws.

    Matsumoto, Takumi; Glisson, Richard R; Reidl, Markus; Easley, Mark E


    Joint compression is an essential element of successful arthrodesis. Although subtalar joint compression generated by conventional screws has been quantified in the laboratory, compression obtainable with headless screws that rely on variable thread pitch to achieve bony contact has not been assessed. This study measured subtalar joint compression achieved by 2 posteriorly placed contemporary headless, variable-pitch screws, and quantified additional compression gained by placing a third screw anteriorly. Ten, unpaired fresh-frozen cadaveric subtalar joints were fixed sequentially using 2 diverging posterior screws (one directed into the talar dome, the other into the talar neck), 2 parallel posterior screws (both ending in the talar dome), and 2 parallel screws with an additional anterior screw inserted from the plantar calcaneus into the talar neck. Joint compression was quantified directly during screw insertion using a novel custom-built measuring device. The mean compression generated by 2 diverging posterior screws was 246 N. Two parallel posterior screws produced 294 N of compression, and augmentation of that construct with a third, anterior screw increased compression to 345 N (P < .05). Compression subsequent to 2-screw fixation was slightly less than that reported previously for subtalar joint fixation with 2 conventional lag screws, but was comparable when a third screw was added. Under controlled testing conditions, 2 tapered, variable-pitch screws generated somewhat less compression than previously reported for 2-screw fixation with conventional headed screws. A third screw placed anteriorly increased compression significantly. Because headless screws are advantageous where prominent screw heads are problematic, such as the load-bearing surface of the foot, their effectiveness compared to other screws should be established to provide an objective basis for screw selection. Augmenting fixation with an anterior screw may be desirable when conditions for

  3. Rotary jagas stipendiume


    Pärnu Rotary klubi aastapäevapeol 11. mail Ammende villas anti stipendium viiele Pärnumaa noorele, teiste seas pälvis preemia Pärnu Ülejõe Gümnaasiumi muusikaõpetaja Fred Rõigas ja Pärnu Muusikakoolis trompetit õppiv Chris Sommer

  4. Rotary jagas stipendiume


    Pärnu Rotary klubi aastapäevapeol 11. mail Ammende villas anti stipendium viiele Pärnumaa noorele, teiste seas pälvis preemia Pärnu Ülejõe Gümnaasiumi muusikaõpetaja Fred Rõigas ja Pärnu Muusikakoolis trompetit õppiv Chris Sommer

  5. DLC screw preload. Loosening prevention

    Ivete Aparecida de Mattias Sartori


    Full Text Available The screw loosening is a reason to prosthetic rehabilitation failure. However, the DLC (Diamond-like carbon screw treatment lead thefriction decrease and sliding between the components, which increases the screw preload benefit and decreases the chance of looseningoccurrence. This case shows a clinical indication of the association of the correct preload applied and the DLC screw, which can be considered an optimized protocol to solve screw loosening recidivate of unitary prosthesis in anterior maxillary site.

  6. Ball Screw Actuator Including a Compliant Ball Screw Stop

    Wingett, Paul T. (Inventor); Hanlon, Casey (Inventor)


    An actuator includes a ball nut, a ball screw, and a ball screw stop. The ball nut is adapted to receive an input torque and in response rotates and supplies a drive force. The ball screw extends through the ball nut and has a first end and a second end. The ball screw receives the drive force from the ball nut and in response selectively translates between a retract position and a extend position. The ball screw stop is mounted on the ball screw proximate the first end to translate therewith. The ball screw stop engages the ball nut when the ball screw is in the extend position, translates, with compliance, a predetermined distance toward the first end upon engaging the ball nut, and prevents further rotation of the ball screw upon translating the predetermined distance.

  7. Piezoelectric Rotary Tube Motor

    Fisher, Charles D.; Badescu, Mircea; Braun, David F.; Culhane, Robert


    A custom rotary SQUIGGLE(Registered TradeMark) motor has been developed that sets new benchmarks for small motor size, high position resolution, and high torque without gear reduction. Its capabilities cannot be achieved with conventional electromagnetic motors. It consists of piezoelectric plates mounted on a square flexible tube. The plates are actuated via voltage waveforms 90 out of phase at the resonant frequency of the device to create rotary motion. The motors were incorporated into a two-axis postioner that was designed for fiber-fed spectroscopy for ground-based and space-based projects. The positioner enables large-scale celestial object surveys to take place in a practical amount of time.

  8. Rotary deformity in degenerative spondylolisthesis

    Kang, Sung Gwon; Kim, Jeong; Kho, Hyen Sim; Yun, Sung Su; Oh, Jae Hee; Byen, Ju Nam; Kim, Young Chul [Chosun University College of Medicine, Gwangju (Korea, Republic of)


    We studied to determine whether the degenerative spondylolisthesis has rotary deformity in addition to forward displacement. We have made analysis of difference of rotary deformity between the 31 study groups of symptomatic degenerative spondylolisthesis and 31 control groups without any symptom, statistically. We also reviewed CT findings in 15 study groups. The mean rotary deformity in study groups was 6.1 degree(the standard deviation is 5.20), and the mean rotary deformity in control groups was 2.52 degree(the standard deviation is 2.16)(p < 0.01). The rotary deformity can be accompanied with degenerative spondylolisthesis. We may consider the rotary deformity as a cause of symptomatic degenerative spondylolisthesis in case that any other cause is not detected.

  9. Biomechanical comparison of cervical transfacet pedicle screws versus pedicle screws

    LIU Guan-yi; XU Rong-ming; MA Wei-hu; SUN Shao-hua; HUANG Lei; YING Jiang-wei; JIANG Wei-yu


    Background Transfacet pedicle screws provide another alternative for standard pedicle screw placement for plate fixation in the Iumbar spine. However, few studies looking at transfacet pedicle screw fixation in the cervical spine are available. Therefore, cervical transfacet pedicle screw fixation and standard pedicle screw fixation techniques were biomechanically compared in this study.Methods Ten fresh human cadaveric cervical spines were harvested. On one side, transfacet pedicle screws were placed at the C3-4, C5-6, and C7-T1 levels. On the other side, pedicle screws were placed at the C3, C5, and C7 levels. The screw insertion technique at each level was randomized for right or left. The starting point for the transfacet pedicle screw insertion was located at the midpoint of the inferolateral quadrant of the lateral mass and the direction of the screw was about 50° caudally in the sagittal plane and about 45° toward the midline in the axial plane. Screws were placed from the inferior articular process, across the facet complex and the pedicle into the body of the caudal vertebra. The entry point for the pedicle screw was located at the midpoint of the superolateral quadrant of the lateral mass, and the direction of the screw was about 45° toward the midline in the axial plane and toward the upper third of the vertebral body in the sagittal plane. After screw placement we performed axial pullout testing.Results All the cervical transfacet pedicle screws and the pedicle screws were inserted successfully. The mean pullout strength for the transfacet pedicle screws was 694 N, while for the pedicle screws 670 N (P=-0.013). In all but six instances (10%), the pedicle screw pullout values exceeded the values for the transfacet pedicle screws; this occurred three times at the C3/C4 level, twice at the C5/C6 level and once at the C7/T1 level. The greatest pullout strength difference at a single level was observed at the C5/C6 level, with a mean difference of 38 N (t

  10. In vitro evaluation of flexural strength of different brands of expansion screws

    Kádna Fernanda Mendes de Oliveira


    Full Text Available OBJECTIVE: The objective of this study was to compare the flexural strength of the stems of three maxillary expanders screws of Morelli, Forestadent and Dentaurum brands. METHODS: The sample consisted of nine expander screws (totalizing of 36 stems, three from each brand, all stainless steel and 12 mm of expansion capacity. The stems of the expander screws were cut with cutting pliers close to the weld region with screw body, then fixed in a universal testing machine Instron 4411 for tests of bending resistance of three points. The ultimate strength in kgF exerted by the machine to bend the stem of the 5 mm screw was recorded and the flexural strength was calculated using a mathematical formula. During the flexural strength test it was verified the modulus of elasticity of the stems by means of Bluehill 2 software. The flexural strength data were subjected to ANOVA with one criterion and Tukey's test, with significance level of 5%. RESULTS: Forestadent screw brand showed the greatest bending strength, significantly higher than Dentaurum. Morelli showed the lowest resistance. CONCLUSION: The flexural strength of the screws varied according to the brand. Forestadent screw showed the greatest resistance and Morelli the lowest. All the three screws were found adequate for use in procedures for rapid maxillary expansion.

  11. Rotary and Magnus balances

    Malcolm, G. N.


    Two wind tunnel techniques for determining part of the aerodynamic information required to describe the dynamic bahavior of various types of vehicles in flight are described. Force and moment measurements are determined with a rotary-balance apparatus in a coning motion and with a Magnus balance in a high-speed spinning motion. Coning motion is pertinent to both aircraft and missiles, and spinning is important for spin stabilized missiles. Basic principles of both techniques are described, and specific examples of each type of apparatus are presented. Typical experimental results are also discussed.




    Rotary blood pumps are used for cardiac assist and cardiopulmonary support since mechanical blood damage is less than with conventional roller pumps. The high shear rate in the rotary pump and the reduced anticoagulation of the patient during prolonged pumping enforces high demands on the biocompati

  13. Rotary actuator for space applications

    Andión, J. A.; Burgui, C.; Migliorero, G.


    SENER is developing a rotary actuator for space applications. The activity, partially funded under ESA GSTP contract, aims at the design, development and performance testing of an innovative rotary actuator concept for space applications. An engineering model has been manufactured and has been tested to demonstrate the compliance with the requirements specification.

  14. Screw-matrix method in dynamics of multibody systems

    Yanzhu, Liu


    In the present paper the concept of screw in classical mechanics is expressed in matrix form, in order to formulate the dynamical equations of the multibody systems. The mentioned method can retain the advantages of the screw theory and avoid the shortcomings of the dual number notation. Combining the screw-matrix method with the tool of graph theory in Roberson/Wittenberg formalism. We can expand the application of the screw theory to the general case of multibody systems. For a tree system, the dynamical equations for each j-th subsystem, composed of all the outboard bodies connected by j-th joint can be formulated without the constraint reaction forces in the joints. For a nontree system, the dynamical equations of subsystems and the kinematical consistency conditions of the joints can be derived using the loop matrix. The whole process of calculation is unified in matrix form. A three-segment manipulator is discussed as an example.

  15. 双螺杆压缩机及膨胀机在高温热泵与能量回收系统中的应用%Applications of Twin Screw Compressor and Expander in High-temperature Heat Pumps and Energy Recovery Systems

    赵兆瑞; 唐昊; 沈九兵; 邢子文


    The demanding of energy conservation, emissions reduction and energy efficiency improvement becomes greater and greater nowadays, so that further investigations and applications on high-temperature heat pumps and energy recovery system are being widely conducted. The high-temperature heat pump mainly includes two kinds of system:heat pumps using R245fa as working medium and those adopting water as working fluid. The energy recovery systems also have two forms of application, i.e., organic rankine cycle (ORC) and water vapor expanding system. In such systems, twin screw compressors and expanders act as key parts, which influences the performance significantly. The application of twin screw compressors and expanders in these systems was introduced, and the research progress and application cases were presented.%随着节能减排、提高能效的需求增大,高温热泵和能量回收系统的研究及应用日益广泛。高温热泵主要有两种类型,一种是使用R245fa等高温工质的高温热泵,另一种是采用水蒸汽介质的高温热泵;能量回收系统也有两种形式,即有机工质郎肯循环(ORC)余热回收以及采用水蒸汽膨胀的回收系统。双螺杆压缩机及膨胀机作为此类系统的核心部件,对系统的性能有着重要的影响。本文介绍了双螺杆压缩机及膨胀机在这类系统中的应用情况,并给出了一些研究进展和应用案例。

  16. Screw bondgraph contact dynamics

    Visser, Martijn; Stramigioli, Stefano; Heemskerk, Cock


    This paper presents an elegant contact dynamics model in screw bondgraph form. It can model the contact between any two objects of finite curvature. It does so by defining a Gauss frame on the surfaces of both objects in the points that are closest to each other. Then it describes how the Gauss fram

  17. Comparison of expansive pedicle screw and polymethylmethacrylate-augmented pedicle screw in osteoporotic sheep lumbar vertebrae: biomechanical and interfacial evaluations.

    Da Liu

    Full Text Available BACKGROUND: It was reported that expansive pedicle screw (EPS and polymethylmethacrylate-augmented pedicle screw (PMMA-PS could be used to increase screw stability in osteoporosis. However, there are no studies comparing the two kinds of screws in vivo. Thus, we aimed to compare biomechanical and interfacial performances of EPS and PMMA-PS in osteoporotic sheep spine. METHODOLOGY/PRINCIPAL FINDINGS: After successful induction of osteoporotic sheep, lumbar vertebrae in each sheep were randomly divided into three groups. The conventional pedicle screw (CPS was inserted directly into vertebrae in CPS group; PMMA was injected prior to insertion of CPS in PMMA-PS group; and the EPS was inserted in EPS group. Sheep were killed and biomechanical tests, micro-CT analysis and histological observation were performed at both 6 and 12 weeks post-operation. At 6-week and 12-week, screw stabilities in EPS and PMMA-PS groups were significantly higher than that in CPS group, but there were no significant differences between EPS and PMMA-PS groups at two study periods. The screw stability in EPS group at 12-week was significantly higher than that at 6-week. The bone trabeculae around the expanding anterior part of EPS were more and denser than that in CPS group at 6-week and 12-week. PMMA was found without any degradation and absorption forming non-biological "screw-PMMA-bone" interface in PMMA-PS group, however, more and more bone trabeculae surrounded anterior part of EPS improving local bone quality and formed biological "screw-bone" interface. CONCLUSIONS/SIGNIFICANCE: EPS can markedly enhance screw stability with a similar effect to the traditional method of screw augmentation with PMMA in initial surgery in osteoporosis. EPS can form better biological interface between screw and bone than PMMA-PS. In addition, EPS have no risk of thermal injury, leakage and compression caused by PMMA. We propose EPS has a great application potential in augmentation of

  18. Effect of Salmon calcitonin combined with expandable pedicle screw internal fixation system in the treatment of senile osteoporotic thoracolumbar fractures%鲑鱼降钙素联合EPS治疗骨质疏松性胸腰椎骨折的疗效

    樊勇; 桑宏勋; 漆伟; 贺伍儿; 张扬; 雷伟


    Objective To investigate the clinical effect of salmon calcitonin combined with expandable pedicle screw ( EPS) internal fixation system in the treatment of senile osteoporotic thoracolumbar fractures. Methods A retrospective analysis was earned out in 78 cases of senile osteoporotic thoracolumbar fractures treating with salmon calcitonin combined expandable pedicle screw internal fixation system from January 2008 to January 2010. Patients were observed before and after treatment. Results The anterior and posterior height of vertebral body after operation were significantly higher than the preoperative ones, respectively ( P < 0. 05 ). The postoperative Cobb ' s angle was significantly lower than the preoperative one ( P < 0. 05 ). Postoperative VAS score and JOA score and BMD were significantly better than preoperative ones (P < 0. 05 ). Conclusion For senile osteoporotic thoracolumbar fractures, the salmon calcitonin combined with expandable pedicle screw internal fixation system has a good clinical effect. The method has the advantages of simple operation, rapid postoperative recovery, high stability, promote bone healing, and the clinical application.%目的 探讨鲑鱼降钙素联合膨胀式椎弓根螺钉(EPS)内固定系统治疗老年骨质疏松性胸腰椎骨折的临床疗效.方法 2008年1月~2010年1月,78例老年骨质疏松性胸腰椎骨折患者在我院采用鲑鱼降钙素联合膨胀式椎弓根螺钉内固定系统进行治疗.观察治疗前后的患者情况.结果 通过治疗后的分析,患者术后的椎体前缘高度和椎体后缘高度均明显的高于术前的患者的椎体前缘高度和椎体后缘高度,数据比较具有显著的差异(P<0.05);术后的Cobb's角度明显的低于术前的Cobb's角度,数据的比较具有显著性的差异(P<0.05).术后的VAS评分和JOA评分以及BMD均明显的优于手术治疗前,数据比较具有显著的差异(P<0.05).结论 对于老年骨质疏松性胸腰椎骨折

  19. Rotary cup slurry atomization

    Sommer, H. T.; Marnicio, R. J.


    The theory of a two-phase flow in a rotating cup atomizer is described. The analysis considers the separation of the solid and liquid media thus realistically modeling the flow of two layers along the inner cup wall: a slurry of increasing solids concentration and a supernatent liquid layer. The analysis is based on the earlier work of Hinze and Milborn (1950) which addressed the flow within a rotary cup for a homogeneous liquid. The superimposition of a settling velocity under conditions of high centrifugal acceleration permits the extended analysis of the separation of the two phases. Appropriate boundary conditions have been applied to the film's free surface and the cup wall and to match the flow characteristics at the liquid-slurry interface. The changing slurry viscosity, increasing nonlinearly with growing solid loading, was also considered. A parameter study illustrates the potential for a cup design to provide optimal slurry and liquid film thicknesses for effective atomization.

  20. Rotary-piston internal combustion engine. Rotationskolbenbrennkraftmaschine

    Eiermann, D.


    Rotary-piston internal combustion engine in trochoidal design with a slide bearing piston which is controlled by a synchronous gear. The gear is covered by an insert unit which is screwed at the eccentric. The insert unit seals the synchronous gear from the remaining machine parts; it has a hollow cylinder which covers the hollow gear of the synchronous gear and is eccentric to the eccentric shaft; it is sealed with a sealing ring from a shoulder of the piston. A further hollow cylinder is coaxial to the eccentric shaft; it surrounds the mount part with a clearance for the pinion; it projects into the boring at the side of the shaft and it is sealed by a sealing ring from the boring. An annular space which is sealed from the remaining engine rooms is on the other side of the bearing. The oil which escapes from the bearing is led from this annular space through the cooling rooms of the piston to the synchronous gear. The oil is carried off into a drain channel through the space which is formed by the coaxial hollow cylinder in the sidewall.


    Glass, J.A.F.


    A reactor control mechanism is described wherein the control is achieved by the partial or total withdrawal of the fissile material which is in the form of a fuel rod. The fuel rod is designed to be raised and lowered from the reactor core area by means of two concentric ball nut and screw assemblies that may telescope one within the other. These screw mechanisms are connected through a magnetic clutch to a speed reduction gear and an accurately controllable prime motive source. With the clutch energized, the fuel rod may be moved into the reactor core area, and fine adjustments may be made through the reduction gearing. However, in the event of a power failure or an emergency signal, the magnetic clutch will become deenergized, and the fuel rod will drop out of the core area by the force of gravity, thus shutting down the operation of the reactor.

  2. Experimental results for a novel rotary active magnetic regenerator

    Engelbrecht, Kurt; Eriksen, Dan; Bahl, Christian


    in a solid refrigerant rather than the temperature change that occurs when a gas is compressed/expanded. This paper presents the general considerations for the design and construction of a high frequency rotary AMR device. Experimental results are presented at various cooling powers for a range of operating...... conditions near room temperature. The device exhibited a no-load temperature span of over 25 K and can absorb a 100 W cooling load at a 20.5 K temperature span....

  3. Development of a rotary instrumentation system, phase 2

    Adler, A.; Skidmore, W.


    A rotary instrumentation system which consists of ruggedized miniature telemetry transmitters installed on the rotating shaft of a gas turbine engine to telemeter the outputs of sensors (strain gages, thermocouples, etc.) on rotating engine components was designed. A small prototype system, which demonstrates the capabilities of performing in the intended environment and demonstrates that the system is expandable to handle about 100 data channels was developed.

  4. A screwing device for handling and assembly of micro screws

    Gegeckaite, Asta; Hansen, Hans Nørgaard; Eriksson, Torbjörn Gerhard


    Nowadays, the application of specially designed handling devices in micro technology is an important topic and a necessity for the industry. Conventional methods for screwing can not be applied directly to micro screws. This is caused by the 3D micro object geometry and dimensions which inducing ...

  5. Adiabatic Wankel type rotary engine

    Kamo, R.; Badgley, P.; Doup, D.


    This SBIR Phase program accomplished the objective of advancing the technology of the Wankel type rotary engine for aircraft applications through the use of adiabatic engine technology. Based on the results of this program, technology is in place to provide a rotor and side and intermediate housings with thermal barrier coatings. A detailed cycle analysis of the NASA 1007R Direct Injection Stratified Charge (DISC) rotary engine was performed which concluded that applying thermal barrier coatings to the rotor should be successful and that it was unlikely that the rotor housing could be successfully run with thermal barrier coatings as the thermal stresses were extensive.

  6. Rotary and Rotary-Percussive Drilling of Lunar Simulant

    Paulsen, G.; Zacny, K.; Maksymuk, M.; Wilson, J.; Santoro, C.; Chu, P.; Davis, K.; Roberts, D.; Kumar, N.; Kusack, A.


    Honeybee Robotics has been developing a rotary and a rotary-preliminary drill system for planetary exploration. This is a test drill with a power rating of 1000 Watt, whose purpose it to test various drill bits and augers in rotary and rotary percussive operation. It is not optimized for power or mass but rather to acquire qualitative drilling data such as penetration rate, power, and torque, temperature, Weight on Bit, vibration energy and others. In addition, the design of the drill allows it to acquire drill bit temperatures and use pneumatic system (instead of augers) for removing of rock cuttings. The drill is designed to have a 1 meter stroke. In addition to the drill system, we have been developing a matching split vacuum chamber, which is 3ft wide, 3ft deep and 11 feet tall. The chamber consists of two smaller chambers (84 inches tall and 48 inches tall) assembled on top of each other. This allows for additional flexibility if only a smaller chamber is required for some testing. The chamber will be able to maintain pressure of below 1 torr. Maintaining sample temperature will be achieved by closed loop cooling system down to -40C or by using liquid nitrogen that allows a temperature of 77K. The test samples can be varied raging from solid rocks, to loose soils to icy soils and pure ice. The sample holder could also be integrated with temperatures for acquiring of thermal data during drilling process.

  7. Percutaneous Iliac Screws for Minimally Invasive Spinal Deformity Surgery

    Michael Y. Wang


    Full Text Available Introduction. Adult spinal deformity (ASD surgeries carry significant morbidity, and this has led many surgeons to apply minimally invasive surgery (MIS techniques to reduce the blood loss, infections, and other peri-operative complications. A spectrum of techniques for MIS correction of ASD has thus evolved, most recently the application of percutaneous iliac screws. Methods. Over an 18 months 10 patients with thoracolumbar scoliosis underwent MIS surgery. The mean age was 73 years (70% females. Patients were treated with multi-level facet osteotomies and interbody fusion using expandable cages followed by percutaneous screw fixation. Percutaneous iliac screws were placed bilaterally using the obturator outlet view to target the ischial body. Results. All patients were successfully instrumented without conversion to an open technique. Mean operative time was 302 minutes and the mean blood loss was 480 cc, with no intraoperative complications. A total of 20 screws were placed successfully as judged by CT scanning to confirm no bony violations. Complications included: two asymptomatic medial breaches at T10 and L5, and one patient requiring delayed epidural hematoma evacuation. Conclusions. Percutaneous iliac screws can be placed safely in patients with ASD. This MIS technique allows for successful caudal anchoring to stress-shield the sacrum and L5-S1 fusion site in long-segment constructs.

  8. Rotary condenser for SC2


    During 1975 the SC2 performance was improved among other things by redesigning some of the elements of the ROTCO (Annual Report 1975, p. 55). The photo shows an interior wiew of the housing of the rotary condenser and of the sixteen sets of shaped stator blades.

  9. Rotary ultrasonic bone drilling: Improved pullout strength and reduced damage.

    Gupta, Vishal; Pandey, Pulak M; Silberschmidt, Vadim V


    Bone drilling is one of the most common operations used to repair fractured parts of bones. During a bone drilling process, microcracks are generated on the inner surface of the drilled holes that can detrimentally affect osteosynthesis and healing. This study focuses on the investigation of microcracks and pullout strength of cortical-bone screws in drilled holes. It compares conventional surgical bone drilling (CSBD) with rotary ultrasonic bone drilling (RUBD), a novel approach employing ultrasonic vibration with a diamond-coated hollow tool. Both techniques were used to drill holes in porcine bones in an in-vitro study. Scanning electron microscopy was used to observe microcracks and surface morphology. The results obtained showed a significant decrease in the number and dimensions of microcracks generated on the inner surface of drilled holes with the RUBD process in comparison to CSBD. It was also observed that a higher rotational speed and a lower feed rate resulted in lower damage, i.e. fewer microcracks. Biomechanical axial pullout strength of a cortical bone screw inserted into a hole drilled with RUBD was found to be much higher (55-385%) than that for CSBD.

  10. The pullout performance of pedicle screws

    Demir, Teyfik


    This brief book systematically discusses all subjects that affect the pullout strength of pedicle screws. These screws are used in spinal surgeries to stabilize the spine. The holding strength of the pedicle screw is vital since loosening of the pedicle screws can cause revision surgeries. Once the pedicle screw is pulled out, it is harder to obtain same stabilization for the fused vertebrae. The book reviews the effect of screw designs, application techniques, cement augmentation, coating of the screw and test conditions on the pullout strength. The studies with finite element analysis were also included.

  11. Carbon nanotube Archimedes screws.

    Oroszlány, László; Zólyomi, Viktor; Lambert, Colin J


    Recently, nanomechanical devices composed of a long stationary inner carbon nanotube and a shorter, slowly rotating outer tube have been fabricated. In this paper, we study the possibility of using such devices as nanoscale transducers of motion into electricity. When the outer tube is chiral, we show that such devices act like quantum Archimedes screws, which utilize mechanical energy to pump electrons between reservoirs. We calculate the pumped charge from one end of the inner tube to the other, driven by the rotation of a chiral outer nanotube. We show that the pumped charge can be greater than one electron per 360° rotation, and consequently, such a device operating with a rotational frequency of 10 MHz, for example, would deliver a current of ≈1 pAmp.

  12. High torque miniature rotary actuator

    Nalbandian, Ruben


    This paper summarizes the design and the development of a miniature rotary actuator (36 mm diameter by 100 mm length) used in spacecraft mechanisms requiring high torques and/or ultra-fine step resolution. This actuator lends itself to applications requiring high torque but with strict volume limitations which challenge the use of conventional rotary actuators. The design challenge was to develop a lightweight (less than 500 grams), very compact, high bandwidth, low power, thermally stable rotary actuator capable of producing torques in excess of 50 N.m and step resolutions as fine as 0.003 degrees. To achieve a relatively high torsional stiffness in excess of 1000 Nm/radian, the design utilizes a combination of harmonic drive and multistage planetary gearing. The unique design feature of this actuator that contributes to its light weight and extremely precise motion capability is a redundant stepper motor driving the output through a multistage reducing gearbox. The rotary actuator is powered by a high reliability space-rated stepper motor designed and constructed by Moog, Inc. The motor is a three-phase stepper motor of 15 degree step angle, producing twenty-four full steps per revolution. Since micro-stepping is not used in the design, and un-powered holding torque is exhibited at every commanded step, the rotary actuator is capable of reacting to torques as high as 35 Nm by holding position with the power off. The output is driven through a gear transmission having a total train ratio of 5120:1, resulting in a resolution of 0.003 degrees output rotation per motor step. The modular design of the multi-stage output transmission makes possible the addition of designs having different output parameters, such as lower torque and higher output speed capability. Some examples of an actuator family based on this growth capability will be presented in the paper.

  13. How Reliable Are The Threaded Locking Screws?

    Karaarslan, Ahmet; Karakaslı, Ahmet; Karcı, Tolga; Aycan, Hakan; Sesli, Erhan


    Objectives: A frequent problem for interlocking nailing, that affects the treatment of the fracture is locking screw deformation. The research question is whether bending resistance is different between high, low and unthreaded locking screws of interlocking femoral nails. Materials and methods. : We used 90 screws for nine groups, ten screws for each group in this experimental study. We performed three-point bending tests on six group of 5 mm screws (titanium, stainless steel, crossed with u...

  14. Torsional stiffness after subtalar arthrodesis using second generation headless compression screws: Biomechanical comparison of 2-screw and 3-screw fixation.

    Riedl, Markus; Glisson, Richard R; Matsumoto, Takumi; Hofstaetter, Stefan G; Easley, Mark E


    Subtalar joint arthrodesis is a common operative treatment for symptomatic subtalar arthrosis. Because excessive relative motion between the talus and calcaneus can delay or prohibit fusion, fixation should be optimized, particularly in patients at risk for subtalar arthrodesis nonunion. Tapered, fully-threaded, variable pitch screws are gaining popularity for this application, but the mechanical properties of joints fixed with these screws have not been characterized completely. We quantified the torsion resistance of 2-screw and 3-screw subtalar joint fixation using this type of screw. Ten pairs of cadaveric subtalar joints were prepared for arthrodesis and fixed using Acutrak 2-7.5 screws. One specimen from each pair was fixed with two diverging posterior screws, and the contralateral joint was fixed using two posterior screws and a third screw directed through the anterior calcaneus into the talar neck. Internal and external torsional loads were applied and joint rotation and torsional stiffness were measured at two torque levels. Internal rotation was significantly less in specimens fixed with three screws. No difference was detectable between 2-screw and 3-screw fixation in external rotation or torsional stiffness in either rotation direction. Both 2-screw and 3-screw fixation exhibited torsion resistance surpassing that reported previously for subtalar joints fixed with two diverging conventional lag screws. Performance of the tapered, fully threaded, variable pitch screws exceeded that of conventional lag screws regardless of whether two or three screws were used. Additional resistance to internal rotation afforded by a third screw placed anteriorly may offer some advantage in patients at risk for nonunion. Copyright © 2017. Published by Elsevier Ltd.

  15. Self-energized screw coupling

    Lefever, A. E.; Totah, R. S.


    Threaded coupling carries its own store of rotational energy. Originally developed to ease task of astronauts assembling structures in space, coupling offers same advantages in other hazardous operations, such as underwater and in and around nuclear reactors. Coupling consists of two parts: crew portion and receptacle. When screw portion is inserted into receptacle and given slight push by operator, trigger pins release ratchet, allowing energy stored in springs to rotate screw into nut in receptacle.

  16. Clinical study on Thread-tooth Arc-track Screw Plate System through expandable channels in the treatment of lumbar instability diseases%经可扩张通道纹牙弧轨钉板系统治疗腰椎失稳性疾病的病例对照研究

    刘峻; 林海朋; 孙金星; 鞠昌军; 谭远超


    出血少、术后疼痛轻、术后恢复快等特点,椎间融合率与开放手术疗效相似,是治疗腰椎失稳性疾病的一种有效方法.纹牙弧轨钉板系统设计合理,安装方便,复位效果好,固定可靠,适合可扩张通道下使用.%Objective: To evaluate the validity and reliability of Thread-tooth Arc-track Screw Plate System (TASPS) in the fixation fusion through expandable channels. Methods: From August 2007 to August 2010,108 patients with lumbar instability were treated with surgery,including 61 males and 47 females,ranging in age from 26 to 57 years,with an average of 41 years. All the patinets were divided into two groups: minimally invasive fusion group and traditional operation group (54 patients in each group). The patients in the minimally invasive fusion group were treated with self-designed TASPS to conduct the fixation fusion through expandable channels by minimally invasive pedicle screw;and the patients in traditional operation group were treated with traditional interbody fixation fusion by pedicle screw. The data were collected and investigated at the 1 st week, 3rd month and 1 st year postoperatively. The comparative parameters of two groups contained the total operation time, the implanted time, the total amount of bleeding; the VAS score, ODI score and improvement rate ai each investigated period; the intervertebral space height of preoperative and postoperative periods; the inefficiency rate of implantation and the fusion rate of postoperative period. Results: All incisions were healed by first stage without any complications such as dural tear,injury of nerve root or cauda equine, intervertebral space infection. The patients in the minimally invasive fusion group needed longer operative time than that of the traditional operation group,but had less total amount of intraoperative and postoperative bleeding and shorter implanted time of pedicle screw than those of the traditional operation group. The VAS scores of

  17. Análise comparativa da expansão maxilar com três marcas de parafusos com limitador posterior: ensaio laboratorial em Typodont Comparative analysis of rapid maxillary expansion using three brands of fan-type expander screw: laboratory trial using typodont

    Ricardo Damo Meneguzzi


    treatment generally involves the expansion of the arch. OBJECTIVE: The aim of this study was to evaluate the expansion pattern obtained with three different fan-type expander screws. METHODS: Using Typodont, 18 expansions were executed, six for each group, according to the expander tested: G1- DentaurumTM; G2- LeoneTM and G3- MorelliTM. For each essay, 13 activations of 2/4 of a turn were done in each appliance, leading to a total activation of 5.2mm. Using a caliper, measurements were taken in the beginning of the testing (T1; in half the total turnings (T2 and in the end of the testing (T3. Different measures were considered: interpremolar width (IP1, intersecond premolar width (IP2, intermolar width (IM and also the arch length (CA. The data obtained was analyzed through Kolmogorov-Smirnov, Tukey and Freeman tests as well as by ANOVA. RESULTS: It could be observed that all tested groups showed a "V" expansion pattern, with major expansion in the anterior region of the arch, that was even more expressive in G3 (IP1=29.85% and IM=9.73%. Increases in the CA measurements were similar for groups G1 and G3 (+12.65% and +12.13%, respectively, and lower for G2 (+8.23%. CONCLUSIONS: It could be concluded that all the fan-type expander screws tested in the present study can be used for treating transverse constriction of the maxilla. However, Morelli expander showed a greater expansion in the anterior region of the arch in relation to the posterior region, which is an important characteristic when treating cleft lip and palate patients. Clinical studies are also necessary to confirm the findings of the present study.

  18. Advancements in rotary steerable technology

    Buker, M. [Phoenix Technology Services, Calgary, AB (Canada)


    The preferred method of drilling horizontal and directional wells is to use conventional measurement while drilling (MWD) systems and mud motors. However, this method has demonstrated some inefficiencies even though it has been used on thousands of wells. The process of slide drilling can result in undesirable doglegs, hole cleaning problems and reduced weight to the bit. A viable alternative to mud motors is rotary steerable technology, which in recent years, has undergone major transformation. Phoenix Technology Services markets and services a rotary steerable system called the Well Director Automatic Directional Drilling System. This paper described rotary steerable technology in general and then focused on the product developed by Phoenix which is in the final stages of becoming commercially available. The mechanical, hydraulic and data transmission methods for the Well Director were described. The tool has to pass a test of drilling without problems for the length of a bit run, and the re-programming function of the tool has to be de-bugged before the Well Director can be commercialized. Phoenix is confident that the tool offers operators a way to drill wellbores more quickly, smoothly and accurately than with conventional technology. 1 tab., 1 fig.

  19. Tunable rotary orbits of matter-wave nonlinear modes in attractive Bose-Einstein condensates

    He, Y J; Wang, H Z [State Key Laboratory of Optoelectronic Materials and Technologies, Sun Yat-Sen University, Guangzhou, 510275 (China); Malomed, Boris A [Department of Physical Electronics, School of Electrical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv 69978 (Israel); Mihalache, Dumitru [Horia Hulubei National Institute for Physics and Nuclear Engineering (IFIN-HH), 407 Atomistilor, Magurele-Bucharest 077125 (Romania)], E-mail:


    We demonstrate that by spatially modulating the Bessel optical lattice where a Bose-Einstein condensate is loaded, we get tunable rotary orbits of nonlinear lattice modes. We show that the radially expanding or shrinking Bessel lattice can drag the nonlinear localized modes to orbits of either larger or smaller radii and the rotary velocity of nonlinear modes can be changed accordingly. The localized modes can even be transferred to the Bessel lattice core when the localized modes' rotations are stopped. Effects beyond the quasi-particle approximation such as destruction of the nonlinear modes by nonadiabatic dragging are also explored.

  20. Computational Fluid Dynamics-Based Design Optimization Method for Archimedes Screw Blood Pumps.

    Yu, Hai; Janiga, Gábor; Thévenin, Dominique


    An optimization method suitable for improving the performance of Archimedes screw axial rotary blood pumps is described in the present article. In order to achieve a more robust design and to save computational resources, this method combines the advantages of the established pump design theory with modern computer-aided, computational fluid dynamics (CFD)-based design optimization (CFD-O) relying on evolutionary algorithms and computational fluid dynamics. The main purposes of this project are to: (i) integrate pump design theory within the already existing CFD-based optimization; (ii) demonstrate that the resulting procedure is suitable for optimizing an Archimedes screw blood pump in terms of efficiency. Results obtained in this study demonstrate that the developed tool is able to meet both objectives. Finally, the resulting level of hemolysis can be numerically assessed for the optimal design, as hemolysis is an issue of overwhelming importance for blood pumps.

  1. A new type of axial-flux magnetic lead screw with inherent spring characteristic

    Lu, Kaiyuan; Xia, Yongming; Pan, Haipeng


    of MLS is proposed, where all the permanent magnets of the rotor and translator are magnetized along the axial direction and it utilizes the propelling force between two opposite magnetic polarity poles for driving. It is a new topology for realizing MLS. The rotor and translator magnets can be made......Magnetic Lead Screw (MLS) can transfer slow linear motion into fast rotary motion offering much higher force density than that of traditional linear permanent magnet machines. It has been developed for ocean wave energy harvester and active damper for electrical vehicles. In this paper, a new type...

  2. Screw fixation for atlantoaxial dislocation related to Down syndrome in children younger than 5 years.

    Ito, Kenyu; Imagama, Shiro; Ito, Zenya; Ando, Kei; Kobayashi, Kazuyoshi; Hida, Tetsuro; Ishikawa, Yoshimoto; Ishiguro, Naoki


    The aim of this study was to present cases of upper cervical fixation in Down syndrome patients younger than 5 years. In two cases, C1 lateral mass screws were installed. However, owing to the irreducible atlantoaxial dislocation, the screw backed out and fractured. Therefore, O-C2 fusion was performed. Furthermore, C2 bilateral lamina screws were added to the C2 pedicle screw for reinforcement. C1-C2 fusion is an option for Down syndrome patients younger than 5 years with atlantoaxial dislocation, when the dislocation is reducible. If the dislocation is irreducible, or the implant cannot be firmly secured, the fixation range should be expanded to O-C2 or below.

  3. Expanding earth

    Carey, S.W.


    Arguments in favor of an expanding earth are presented. The author believes that the theory of plate tectonics is a classic error in the history of geology. The case for the expanding earth is organized in the following way: introductory review - face of the earth, development of expanding earth concept, necessity for expansion, the subduction myth, and definitions; some principles - scale of tectonic phenomena, non-uniformitarianism, tectonic profile, paleomagnetism, asymmetry of the earth, rotation of the earth, and modes of crustal extension; regional studies - western North America, Central America, South-East Asia, and the rift oceans; tests and cause of expansion. 824 references, 197 figures, 11 tables. (RWR)

  4. Rotary-atomizer electric power generator

    Nguyen, Trieu; Tran, Tuan; de Boer, Hans L.; van den Berg, Albert; Eijkel, Jan C.T.


    We report experimental and theoretical results on a ballistic energy-conversion method based on a rotary atomizer working with a droplet acceleration-deceleration cycle. In a rotary atomizer, liquid is fed onto the center of a rotating flat surface, where it spreads out under the action of the centr

  5. Rotary-atomizer electric power generator

    Nguyen, Trieu; Tran, Tuan; Boer, de Hans; Berg, van den Albert; Eijkel, Jan C.T.


    We report experimental and theoretical results on a ballistic energy-conversion method based on a rotary atomizer working with a droplet acceleration-deceleration cycle. In a rotary atomizer, liquid is fed onto the center of a rotating flat surface, where it spreads out under the action of the centr

  6. Wankel engines as steam expanders: design considerations

    Badr, O.; Naik, S.; O' Callaghan, P.W.; Probert, S.D. (Cranfield Inst. of Tech., Bedford (GB). Dept. of Applied Energy)


    Rotary Wankel engines offer several advantages compared with turbines and other positive-displacement machines as the expansion devices in low-power-output Rankine-cycle systems. So a Wankel expander was selected as the most appropriate device for a steam Rankine-engine, operating principally as a mini combined heat-and-power unit, providing a mechanical output of 5-20 kW. A computer-aided-design technique for selecting the optimal geometry and location of the ports of the expander is described: the computer programs are available from the authors. Lubrication and possible material combinations are also discussed. (author).

  7. Large-amplitude rotary induced-strain (LARIS) actuator proof-of-concept demonstrator

    Giurgiutiu, Victor; Rogers, Craig A.; McNeil, Shane


    Induced-strain materials can produce very large forces and, hence, large energy density, but small actual displacements. A new concept for obtaining large-amplitude rotary displacements from small linear displacements generated by induced-strain material stacks is proposed. The concept utilizes the theory of twist-warping coupling in thin-wall open tubes. The theory of the proposed solid-state axial-to- rotary converter-amplifier, together with the appropriate bibliographical references, is given. A simple formula is generated for estimating the axial-to-rotary conversion- amplification coefficient from the geometrical length, L, and enclosed area, A, of the open tube. A large-displacement induced-strain rotary (LARIS) actuator proof-of-concept demonstrator was built and tested to verify and validate the theoretical developments. The LARIS actuator consisted of a 28 mm diameter, 1.2 m length open tube and a 120 micrometer, -1000 V PZT translator. The experimental set-up and the excitation and measuring equipment are fully described in the paper. A maximum rotary displacement of 8 degrees was measured, and the linear relationship between the rotation coefficient, the tube length, L, and the inverse of the enclosed area, A, was verified. An improved theoretical model, that accounts for the experimentally observed zero off-set, is also given. The theoretical developments and experimental tests presented in this paper show that the proposed LARIS actuator, based on a novel solid-state axial-to-rotary converter-amplifier utilizing the warping-torsion coupling of an open tube, is a viable design option, of great constructive simplicity and very low parts count. This concept can be successfully used in a series of aerospace and mechanical engineering applications, as for example in the actuation of adaptive control surfaces for aircraft wings and helicopter blades. The 8 degree rotary displacement capabilities measured on the proof-of-concept demonstrator can be easily

  8. Cancellous Screws Are Biomechanically Superior to Cortical Screws in Metaphyseal Bone.

    Wang, Tim; Boone, Christopher; Behn, Anthony W; Ledesma, Justin B; Bishop, Julius A


    Cancellous screws are designed to optimize fixation in metaphyseal bone environments; however, certain clinical situations may require the substitution of cortical screws for use in cancellous bone, such as anatomic constraints, fragment size, or available instrumentation. This study compares the biomechanical properties of commercially available cortical and cancellous screw designs in a synthetic model representing various bone densities. Commercially available, fully threaded, 4.0-mm outer-diameter cortical and cancellous screws were tested in terms of pullout strength and maximum insertion torque in standard-density and osteoporotic cancellous bone models. Pullout strength and maximum insertion torque were both found to be greater for cancellous screws than cortical screws in all synthetic densities tested. The magnitude of difference in pullout strength between cortical and cancellous screws increased with decreasing synthetic bone density. Screw displacement prior to failure and total energy absorbed during pullout strength testing were also significantly greater for cancellous screws in osteoporotic models. Stiffness was greater for cancellous screws in standard and osteoporotic models. Cancellous screws have biomechanical advantages over cortical screws when used in metaphyseal bone, implying the ability to both achieve greater compression and resist displacement at the screw-plate interface. Surgeons should preferentially use cancellous over cortical screws in metaphyseal environments where cortical bone is insufficient for fixation. [Orthopedics.2016; 39(5):e828-e832.].

  9. Rotary Valve FY 2016 Highlights

    Fitsos, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)


    The fiscal year started with the Rotary Valve (RV) being reassembled after having crashed in June of 2015. The crash occurred when the RV inner surface contacted the housing. The cause of the crash was never confirmed. No particles were found in the 2.5 thousandths of an inch gap and the filters the helium gas passed through were all clean. There were marks on the bearings that looked like electrostatic discharge as shown below in Figure 1. These marks hadn’t been seen before and there were similar discharge marks on some of the ball bearings. Examples of this were found in a literature search of bearing failures. This leads to a possible cause due to this arcing affecting the rotational accuracy of the bearings driving the RV into the housing.

  10. Aerodynamic seals for rotary machine

    Bidkar, Rahul Anil; Cirri, Massimiliano; Thatte, Azam Mihir; Williams, John Robert


    An aerodynamic seal assembly for a rotary machine includes multiple sealing device segments disposed circumferentially intermediate to a stationary housing and a rotor. Each of the segments includes a shoe plate with a forward-shoe section and an aft-shoe section having multiple labyrinth teeth therebetween facing the rotor. The sealing device segment also includes multiple flexures connected to the shoe plate and to a top interface element, wherein the multiple flexures are configured to allow the high pressure fluid to occupy a forward cavity and the low pressure fluid to occupy an aft cavity. Further, the sealing device segments include a secondary seal attached to the top interface element at one first end and positioned about the flexures and the shoe plate at one second end.

  11. Expanding subjectivities

    Lundgaard Andersen, Linda; Soldz, Stephen


    A major theme in recent psychoanalytic thinking concerns the use of therapist subjectivity, especially “countertransference,” in understanding patients. This thinking converges with and expands developments in qualitative research regarding the use of researcher subjectivity as a tool to understa...

  12. A novel in-plane mode rotary ultrasonic motor

    Lu Xiaolong


    Full Text Available Ultrasonic motors have the merits of high ratio of torque to volume, high positioning precision, intrinsic holding torque, etc., compared to the conventional electromagnetic motors. There have been several potential applications for this type of motor in aerospace exploration, but bearings and bonding mechanism of the piezoelectric ring in the motors limit the performance of them in the space operation conditions. It is known that the Langevin type transducer has excellent energy efficiency and reliability. Hence using the Langevin type transducer in ultrasonic motors may improve the reliability of piezoelectric motors for space applications. In this study, a novel in-plane mode rotary ultrasonic motor is designed, fabricated, and characterized. The proposed motor operates in in-plane vibration mode which is excited by four Langevin-type bending vibrators separately placed around a ring-shaped stator. Two tapered rotors are assembled to the inner ring of the stator and clamped together by a screw nut. In order to make the motor more stable and convenient to fix, a thin cylindrical support is placed under the stator ring. Due to its no-bearing structure and Langevin transducer excitation, the prototype ultrasonic motor may operate well in aeronautic and astronautic environments.

  13. Unidirectional rotary motion in achiral molecular motors.

    Kistemaker, Jos C M; Štacko, Peter; Visser, Johan; Feringa, Ben L


    Control of the direction of motion is an essential feature of biological rotary motors and results from the intrinsic chirality of the amino acids from which the motors are made. In synthetic autonomous light-driven rotary motors, point chirality is transferred to helical chirality, and this governs their unidirectional rotation. However, achieving directional rotary motion in an achiral molecular system in an autonomous fashion remains a fundamental challenge. Here, we report an achiral molecular motor in which the presence of a pseudo-asymmetric carbon atom proved to be sufficient for exclusive autonomous disrotary motion of two appended rotor moieties. Isomerization around the two double bonds enables both rotors to move in the same direction with respect to their surroundings--like wheels on an axle--demonstrating that autonomous unidirectional rotary motion can be achieved in a symmetric system.

  14. Rotary endodontics in primary teeth - A review.

    George, Sageena; Anandaraj, S; Issac, Jyoti S; John, Sheen A; Harris, Anoop


    Endodontic treatment in primary teeth can be challenging and time consuming, especially during canal preparation, which is considered one of the most important steps in root canal therapy. The conventional instrumentation technique for primary teeth remains the "gold-standard" over hand instrumentation, which makes procedures much more time consuming and adversely affects both clinicians and patients. Recently nickel-titanium (Ni-Ti) rotary files have been developed for use in pediatric endodontics. Using rotary instruments for primary tooth pulpectomies is cost effective and results in fills that are consistently uniform and predictable. This article reviews the use of nickel-titanium rotary files as root canal instrumentation in primary teeth. The pulpectomy technique is described here according to different authors and the advantages and disadvantages of using rotary files are discussed.

  15. Kinetic characteristic for a synchronal rotary compressor

    Qu Zongchang; Feng Jianmei; Zhou Hui; Yang Hua


    An angular speed, acceleration and tangential leakage of a synchronal rotary compressor in which both bladed rotor and a cylinder are discussed. The calculation formulae of revolving speed of cylinder and relative speed between the cylinder and bladed rotor are deduced detailedly in this paper. The variation of tangential speed and cylinder acceleration with angular position is investigated for a complete cycle. And some key parameters affected the relative speed are found out, viz, the relative speed depends on the radius of the cylinder and rotary speed of the axis, and the ratio of the cylinder to bladed rotor has not too much influence. It is the theoretic basis of designing and optimizing of structure characteristic of a synchronal rotary compressor. Also a computing formula of leakage related with rotary speed is deduced. It could supply

  16. Analysis of the Rotary Ultrasonic Machining Mechanism


    Ultrasonic machining (USM) is considered as an effective method for machining hard and brittle materials such as glass, engineering ceramics, semiconductors, diamonds, metal composites and so on. However, the low material removal rate due to using abrasive slurry limits further application of USM. Rotary ultrasonic machining (rotary USM) superimposes rotational movement on the tool head that vibrates at ultrasonic frequency (20 kHz) simultaneously. The tool is made of mild steel coated or bonded with diamon...




    Full Text Available INTRODUCTION: Accidents with expansion screw activation keys are r eported in the literature 1,2 . A simple method to prevent such accident is to use a modified periodontal explorer as a key for expansion screw activation. A no.17 per iodontal explorer (fig 1 is cut at its first terminal bend (fig 2. The second section is bent m ore vertically to the long axis of the shaft (fig 3. This part which is tapered and stiff enough to ac tivate the screw is tried extra orally into the screw. It is further trimmed in such a way that onl y a mm of instrument can project through the screw hole (fig 4. Now a safe key for activating t he maxillary expansion screw is ready to use (fig 5. Once the patient’s parent or guardian succes sfully repeat the activation procedure in office, the instrument can be given to them for hom e use

  18. Rotary impeller refinement of 7075Al alloy

    WANG Liping; GUO Erjun; HUANG Yongchang; LU Bin


    The effects of four parameters, gas flow, rotational speed, refining time, and stewing time, on the rotary impeller refinement of 7075 Al were studied. The effects of C2Cl6refining, rotary impeller refuting, and composite refining of 7075 AI alloy were compared with each other. The results showed that the greatest impact parameter of rotary impeller refinement was rotational speed, followed by gas flow, refining time, and stewing time. The optimum purification parameters obtained by orthogonal analysis were as follows: rotor speed of 400 r/min, inert gas flow of 0.4 mL/h, refining time of 15 min, and stewing time of 6 min. The best degassing effect can be obtained by the composite refuting of C2Cl6 and rotary impeller. The degassing rate of C2Cl6 rotary impeller, and composite refining was 34.5%, 69.2%, and 78%, respectively. The mechanical properties of the specimen refined by rotary impeller were higher than those by C2C16 refining, but lower than those by composite refining.

  19. Biomechanical Analysis of Latarjet Screw Fixation: Comparison of Screw Types and Fixation Methods.

    Shin, Jason J; Hamamoto, Jason T; Leroux, Timothy S; Saccomanno, Maristella F; Jain, Akshay; Khair, Mahmoud M; Mellano, Christen R; Shewman, Elizabeth F; Nicholson, Gregory P; Romeo, Anthony A; Cole, Brian J; Verma, Nikhil N


    To compare the initial fixation stability, failure strength, and mode of failure of 5 different screw types and fixation methods commonly used for the classic Latarjet procedure. Thirty-five fresh-frozen cadaveric shoulder specimens were allocated into 5 groups. A 25% anteroinferior glenoid defect was created, and a classic Latarjet coracoid transfer procedure was performed. All grafts were fixed with 2 screws, differing by screw type and/or fixation method. The groups included partially threaded solid 4.0-mm cancellous screws with bicortical fixation, partially threaded solid 4.0-mm cancellous screws with unicortical fixation, fully threaded solid 3.5-mm cortical screws with bicortical fixation, partially threaded cannulated 4.0-mm cancellous screws with bicortical fixation, and partially threaded cannulated 4.0-mm captured screws with bicortical fixation. All screws were stainless steel. Outcomes included cyclic creep and secant stiffness during cyclic loading, as well as load and work to failure during the failure test. Intergroup comparisons were made by a 1-way analysis of variance. There were no significant differences among different screw types or fixation methods in cyclic creep or secant stiffness after cyclic loading or in load to failure or work to failure during the failure test. Post-failure radiographs showed evidence of screw bending in only 1 specimen that underwent the Latarjet procedure with partially threaded solid cancellous screws with bicortical fixation. The mode of failure for all specimens analyzed was screw cutout. In this biomechanical study, screw type and fixation method did not significantly influence biomechanical performance in a classic Latarjet procedure. When performing this procedure, surgeons may continue to select the screw type and method of fixation (unicortical or bicortical) based on preference; however, further studies are required to determine the optimal method of treatment. Surgeons may choose the screw type and

  20. Shock-Absorbent Ball-Screw Mechanism

    Hirr, Otto A., Jr.; Meneely, R. W.


    Actuator containing two ball screws in series employs Belleville springs to reduce impact loads, thereby increasing life expectancy. New application of springs increases reliability of equipment in which ball screws commonly used. Set of three springs within lower screw of ball-screw mechanism absorbs impacts that result when parts reach their upper and lower limits of movement. Mechanism designed with Belleville springs as shock-absorbing elements because springs have good energy-to-volume ratio and easily stacked to attain any stiffness and travel.

  1. Vortex conception of rotor and mutual effect of screw/propellers

    Lepilkin, A. M.


    A vortex theory of screw/propellers with variable circulation according to the blade and its azimuth is proposed, the problem is formulated and circulation is expanded in a Fourier series. Equations are given for inductive velocities in space for crews, including those with an infinitely large number of blades and expansion of the inductive velocity by blade azimuth of a second screw. Multiparameter improper integrals are given as a combination of elliptical integrals and elementary functions, and it is shown how to reduce elliptical integrals of the third kind with a complex parameter to integrals with a real parameter.

  2. High Bandwidth Rotary Fast Tool Servos and a Hybrid Rotary/Linear Electromagnetic Actuator

    Montesanti, Richard Clement [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)


    This thesis describes the development of two high bandwidth short-stroke rotary fast tool servos and the hybrid rotary/linear electromagnetic actuator developed for one of them. Design insights, trade-o® methodologies, and analytical tools are developed for precision mechanical systems, power and signal electronic systems, control systems, normal-stress electromagnetic actuators, and the dynamics of the combined systems.


    Preetam Sarkar


    Full Text Available Fruit by-products have found limited applications in the food industry. They have been primarily used as animal feed, applied to agricultural land for soil amendment or composted and applied to farms for growing crops. Some of these disposal methods are not environment friendly, while others are costly. This study was undertaken to examine the possibility of utilizing peach pomace as a source of soluble dietary fiber in expanded extruded food products. Peach pomace was combined with rice flour at four different levels. The four blends were mixed, dried to a moisture level of 13.5% (w/w and ground to flour. These blends were extruded in a twin-screw extruder (Clextral EV-25 at a feed flow rate of 15 kg/h. The extruded products were analyzed for physical and textural properties. The apparent and true densities for the extrudates decreased from 183.93 to 133.94 kg/m3 and 1275.31 to 1171.2 kg/m3, respectively. A linear increase in extrudate porosity (85.11-88.54% and radial expansion ratio (13.5-19.3 and a steady decrease in breaking strength (104-50.74 kPa were observed with increasing peach pomace level in the blends. This study demonstrates the potential of extrusion processing as a tool for fruit by-product utilization, which will not only enhance consumption of soluble dietary fiber but will also increase the overall fruit utilization.

  4. Man-made rotary nanomotors: a review of recent developments

    Kim, Kwanoh; Guo, Jianhe; Liang, Z. X.; Zhu, F. Q.; Fan, D. L.


    The development of rotary nanomotors is an essential step towards intelligent nanomachines and nanorobots. In this article, we review the concept, design, working mechanisms, and applications of state-of-the-art rotary nanomotors made from synthetic nanoentities. The rotary nanomotors are categorized according to the energy sources employed to drive the rotary motion, including biochemical, optical, magnetic, and electric fields. The unique advantages and limitations for each type of rotary nanomachines are discussed. The advances of rotary nanomotors is pivotal for realizing dream nanomachines for myriad applications including microfluidics, biodiagnosis, nano-surgery, and biosubstance delivery.

  5. Man-Made Rotary Nanomotors: A Review of Recent Development

    Kim, Kwanoh; Guo, Jianhe; Liang, Z. X.; Zhu, F. Q.; Fan, D. L.


    The development rotary nanomotors is an essential step towards intelligent nanomachines and nanorobots. In this article, we review the concept, design, working mechanisms, and applications of the state-of-the-art rotary nanomotors made from synthetic nanoentities. The rotary nanomotors are categorized according to the energy sources employed to drive the rotary motion, including biochemical, optical, magnetic, and electric fields. The unique advantages and limitations for each type of rotary nanomachines are discussed. The advances of rotary nanomotors is pivotal for realizing dream nanomachines for myriad applications including microfluidics, biodiagnosis, nano-surgery, and biosubstance delivery. PMID:27152885

  6. Man-made rotary nanomotors: a review of recent developments.

    Kim, Kwanoh; Guo, Jianhe; Liang, Z X; Zhu, F Q; Fan, D L


    The development of rotary nanomotors is an essential step towards intelligent nanomachines and nanorobots. In this article, we review the concept, design, working mechanisms, and applications of state-of-the-art rotary nanomotors made from synthetic nanoentities. The rotary nanomotors are categorized according to the energy sources employed to drive the rotary motion, including biochemical, optical, magnetic, and electric fields. The unique advantages and limitations for each type of rotary nanomachines are discussed. The advances of rotary nanomotors is pivotal for realizing dream nanomachines for myriad applications including microfluidics, biodiagnosis, nano-surgery, and biosubstance delivery.

  7. Coal desulfurization in a rotary kiln combustor

    Cobb, J.T. Jr.


    The purpose of this project was to demonstrate the combustion of coal and coal wastes in a rotary kiln reactor with limestone addition for sulfur control. The rationale for the project was the perception that rotary systems could bring several advantages to combustion of these fuels, and may thus offer an alternative to fluid-bed boilers. Towards this end, an existing wood pyrolysis kiln (the Humphrey Charcoal kiln) was to be suitably refurbished and retrofitted with a specially designed version of a patented air distributor provided by Universal Energy, Inc. (UEI). As the project progressed beyond the initial stages, a number of issues were raised regarding the feasibility and the possible advantages of burning coals in a rotary kiln combustor and, in particular, the suitability of the Humphrey Charcoal kiln as a combustor. Instead, an opportunity arose to conduct combustion tests in the PEDCO Rotary Cascading-Bed Boiler (RCBB) commercial demonstration unit at the North American Rayon CO. (NARCO) in Elizabethton, TN. The tests focused on anthracite culm and had two objectives: (a) determine the feasibility of burning anthracite culms in a rotary kiln boiler and (b) obtain input for any further work involving the Humphrey Charcoal kiln combustor. A number of tests were conducted at the PEDCO unit. The last one was conducted on anthracite culm procured directly from the feed bin of a commercial circulating fluid-bed boiler. The results were disappointing; it was difficult to maintain sustained combustion even when large quantities of supplemental fuel were used. Combustion efficiency was poor, around 60 percent. The results suggest that the rotary kiln boiler, as designed, is ill-suited with respect to low-grade, hard to burn solid fuels, such as anthracite culm. Indeed, data from combustion of bituminous coal in the PEDCO unit suggest that with respect to coal in general, the rotary kiln boiler appears inferior to the circulating fluid bed boiler.

  8. Anatomic comparison of transarticular screws with lateral mass screws in cervical vertebrae

    LIU Guan-yi; XU Rong-ming; MA Wei-hu; RUAN Yong-ping; SUN Shao-hua; HUANG Lei


    Objective: To compare the potential incidence of nerve root (ventral and dorsal ramus) injury caused by cervical transarticular screws and Roy-Camille lateral mass screws.Methods: Insertion techniques with Klekamp transarticular screws and Roy-Camille lateral mass screws were respectively performed in this study. Each technique involved four specimens and 40 screws, which were inserted from C3 to C7. And 20-mm-long screws were used to overpenetrate the ventral cortex. The anterolateral aspect of the cervical spine was carefully dissected to allow observation of the screw-ramus relationship.Results: The overall percentage of nerve invasion was significantly lower with Klekamp (45%) technique than with Roy-Camille (85%) technique (P<0.05). The largest percentage of nerve invasion for Klekamp transarticular screws was found at the dorsal ramus (25%), followed by the ventral ramus (15%) and the bifurcation of the ventral dorsal ramus (5%). The largest percentage of nerve invasion for Roy-Camille lateral mass screws was found at the ventral ramus (80%).Conclusion: The potential risk of nerve root invasion is lower with Klekamp transarticular screws than with Roy-Camille lateral mass screws.

  9. Twin-Screw Extruders in Ceramic Extrusion

    Wiedmann, Werner; Hölzel, Maria

    The machines mainly used for compounding plastics, chemicals and food are co-rotating, closely intermeshing twin-screw extruders. Some 30 000 such extruders are in use worldwide, about 1/3 are ZSKs from Coperion Werner & Pfleiderer, Stuttgart. In the chemical industry more and more batch mixers are being replaced by continuous twin-screw kneaders.

  10. Simple Technique for Removing Broken Pedicular Screws

    A Agrawal


    Full Text Available The procedure for removing a broken pedicle screw should ideally be technically easy and minimally invasive, as any damage to the pedicle, during removal of the broken screw, may weaken the pedicle, thus compromising on the success of re-instrumentation. We describe the case of a 32-year old man who had undergone surgery for traumatic third lumbar vertebral body fracture three years prior to current admission and had developed the complication of pedicle screw breakage within the vertebral body. The patient underwent re-exploration and removal of the distal screws. Through a paravertebral incision and muscle separation, the screws and rods were exposed and the implants were removed.

  11. Twin screw granulation: steps in granule growth.

    Dhenge, Ranjit M; Cartwright, James J; Hounslow, Michael J; Salman, Agba D


    The present work focuses on the study of the progression of granules in different compartments along the length of screws in a twin screw granulator (TSG). The effects of varying powder feed rate; liquid to solid ratio and viscosity of granulation liquid on properties of granules was studied. The bigger granules produced at the start of the process were found to change in terms of size, shape and strength along the screw length at all the conditions investigated. The granules became more spherical and their strength increased along the screw length. Tracer granules were also introduced in order to understand the role of kneading and conveying elements in the TSG. The kneading elements promoted consolidation and breakage while the conveying elements led to coalescence, breakage and some consolidation. The results presented here help to provide a qualitative and quantitative understanding of the twin screw granulation process.

  12. Twin screw subsurface and surface multiphase pumps

    Dass, P. [CAN-K GROUP OF COMPANIES, Edmonton, Alberta (Canada)


    A new subsurface twin screw multiphase pump has been developed to replace ESP and other artificial lift technologies. This technology has been under development for a few years, has been field tested and is now going for commercial applications. The subsurface twin screw technology consists of a pair of screws that do not touch and can be run with a top drive or submersible motor; and it carries a lot of benefits. This technology is easy to install and its low slippage makes it highly efficient with heavy oil. In addition twin screw multiphase pumps are capable of handling high viscosity fluids and thus their utilization can save water when used in thermal applications. It also induces savings of chemicals because asphaltenes do not break down easily as well as a reduction in SOR. The subsurface twin screw multiphase pump presented herein is an advanced technology which could be used in thermal applications.

  13. Comparison of interfaces of different pedicle screws with micro-CT technique in lumbar vertebrae with osteoporosis of sheep

    Da LIU


    Full Text Available Objective To compare the changes in interfaces of expandable pedicle screw (EPS and polymethylmethacrylateenhanced pedicle screw (PMMA-PS after being used in osteoporotic sheep lumbar vertebrae with micro-CT technique. Methods Six lumbar vertebrae (L1-L6 in each sheep were randomly divided into three different screw-insertion groups (two vertebrae with four pedicles in each group after reproduction of osteoporosis in sheep. After making the pilot hole using the same method, CPS was inserted through the pilot hole into vertebral body in CPS group, while PMMA (1.0ml was injected into the pilot hole prior to the insertion of CPS in PMMA-PS group, and EPS was inserted through pedicle into vertebral body in EPS group. All the sheep were sacrificed, and lumbar vertebrae (L1-L6 were harvested respectively at the 6- and 12-week postoperatively. The micro-CT three dimensional reconstruction and histomorphometric analysis were performed to evaluate the interfacial conditions. Results  It was clearly demonstrated that interface was formed where the bone trabeculae was directly in contact with the screw to form "screw-bone" interface in both CPS and EPS groups both 6 weeks and 12 weeks after the operation. The screw was fully surrounded by PMMA and formed "screw-PMMA-bone" interface in PMMA-PS group. The anterior part of EPS expanded in vertebral body to form a clawlike structure, pressing against the surrounding bone trabeculae, thus significantly improved the local bone quality (amount and density of bone trabeculae. From 6 weeks to 12 weeks after the operation, there was no visual difference in bone quality around the screw in both CPS and PMMA-PS groups. There was no degradation and absorption of PMMA, and it led to form the second non-biological interface in PMMA-PS group. Nevertheless, bone quality around expanding part of EPS at 12-week post-operation was significantly improved compared with that at 6-week post-operation, thus forming a good

  14. Coal gasification: New challenge for the Beaumont rotary feeder

    Stelian, J.


    The use of rotary feeders in the coal gasification process is described with emphasis on the efficient conversion of coal to clean gaseous fuels. Commercial applications of the rotary feeder system are summarized.

  15. Development of a controlled release formulation by continuous twin screw granulation: Influence of process and formulation parameters.

    Vanhoorne, V; Vanbillemont, B; Vercruysse, J; De Leersnyder, F; Gomes, P; Beer, T De; Remon, J P; Vervaet, C


    The aim of this study was to evaluate the potential of twin screw granulation for the continuous production of controlled release formulations with hydroxypropylmethylcellulose as hydrophilic matrix former. Metoprolol tartrate was included in the formulation as very water soluble model drug. A premix of metoprolol tartrate, hydroxypropylmethylcellulose and filler (ratio 20/20/60, w/w) was granulated with demineralized water via twin screw granulation. After oven drying and milling, tablets were produced on a rotary Modul™ P tablet press. A D-optimal design (29 experiments) was used to assess the influence of process (screw speed, throughput, barrel temperature and screw design) and formulation parameters (starch content of the filler) on the process (torque), granule (size distribution, shape, friability, density) and tablet (hardness, friability and dissolution) critical quality attributes. The torque was dominated by the number of kneading elements and throughput, whereas screw speed and filling degree only showed a minor influence on torque. Addition of screw mixing elements after a block of kneading elements improved the yield of the process before milling as it resulted in less oversized granules and also after milling as less fines were present. Temperature was also an important parameter to optimize as a higher temperature yielded less fines and positively influenced the aspect ratio. The shape of hydroxypropylmethylcellulose granules was comparable to that of immediate release formulations. Tensile strength and friability of tablets were not dependent on the process parameters. The use of starch as filler was not beneficial with regard to granule and tablet properties. Complete drug release was obtained after 16-20h and was independent of the design's parameters.

  16. Pneumatic Rotary Actuator Angle Control System

    王鹏; 彭光正; 伍清河


    Based on the adaptive control method, a kind of parameter adjustor was used to control pneumatic rotary actuator to track the expected output. The system uses electropneumatic proportional valve as control device, which adjusts the gas flow of actuator 's two cavities, then changes the pressure of cavity and pushes the piston of actuator to move, so the rotary actuator 's axis can be made to revolve to the required angle at last. According to the characteristic of pneumatic system, the control system was described with a fourth-order mathematic model. The control rule is deduced by model reference adaptive control method. By the result of experiment, it was proved that by using the adaptive control method, the output of rotary actuator could track the expected value timely and accurately.

  17. Novel precision piezoelectric step rotary actuator

    LIU Jianfang; YANG Zhigang; ZHAO Hongwei; CHENG Guangming


    A novel piezoelectric (PZT) precision step rotary actuator was developed on the basis of PZT technology.It adopts the principle of bionics and works with an inside anchoring/loosening of the stator and a distortion structure of the uniformly distributed thin flexible hinge to solve problems such as ineffective anchoring/loosening,low step rotary frequency,small travel,poor resolution,low speed and unsteady output.The developed actuator is characterized by high frequency (30 Hz),high speed (380 μrad/s),large travel (>270°),high resolution (1 μrad/step),and work stability.It greatly improves the ability to drive the existing PZT step rotary actuator.The new actuator can be applied in the field of micromanipulation and precision engineering,including precision driving and positioning and optics engineering.

  18. Ka-band waveguide rotary joint

    Yevdokymov, Anatoliy


    The authors present a design of a waveguide rotary joint operating in Ka-band with central frequency of 33 GHz, which also acts as an antenna mount. The main unit consists of two flanges with a clearance between them; one of the flanges has three circular choke grooves. Utilisation of three choke grooves allows larger operating clearance. Two prototypes of the rotary joint have been manufactured and experimentally studied. The observed loss is from 0.4 to 0.8 dB in 1.5 GHz band.

  19. Pedicle screw placement in the lumbar spine: effect of trajectory and screw design on acute biomechanical purchase.

    Wray, Steven; Mimran, Ronnie; Vadapalli, Sasidhar; Shetye, Snehal S; McGilvray, Kirk C; Puttlitz, Christian M


    OBJECT Low bone mineral density in patients undergoing lumbar spinal surgery with screws is an especially difficult challenge because poor bone quality can severely compromise the maximum achievable purchase of the screws. A relatively new technique, the cortical bone screw trajectory, utilizes a medialized trajectory in the caudocephalad direction to engage a greater amount of cortical bone within the pars interarticularis and pedicle. The objectives of this cadaveric biomechanical study were to 1) evaluate a cortical screw system and compare its mechanical performance to the traditional pedicle screw system; 2) determine differences in bone quality associated with the cortical screw trajectory versus the normal pedicle screw insertion technique; 3) determine the cortical wall breach rate with both the cortical and traditional screw trajectories; and 4) determine the performance of the traditional screw in the cortical screw trajectory. METHODS Fourteen fresh frozen human lumbar spine sections (L1-5) were used in this study (mean age 57 ± 19 years). The experimental plan involved drilling and tapping screw holes for 2 trajectories under navigation (a traditional pedicle screw and a cortical screw) in both high-and low-quality vertebrae, measuring the bone quality associated with these trajectories, placing screws in the trajectories, and evaluating the competence of the screw purchase via 2 mechanical tests (pullout and toggle). The 3 experimental variants were 1) traditional pedicle screws placed in the traditional pedicle screw trajectory, 2) traditional pedicle screws placed in the cortical screw trajectory, and 3) cortical screws placed in the cortical screw trajectory. RESULTS A statistically significant increase in bone quality was observed for the cortical trajectories with a cortical screw (42%; p parameter comparisons (screw type and trajectory) between high-quality and lowquality samples were significant (p parameters determined from pullout and toggle

  20. Sizing and performance features of rotary and reciprocating positive displacement pumps

    Cooper Paul; Wang Chaowei


    An overview of some popular rotary and reciprocating positive displacement (PD)pump types is given with the objective of presenting and comparing the respective sizing relationships and performance features.Reciprocating pumps discussed are the piston and plunger types.Rotary pumps addressed are gear (external and internal),vane,lobe,screw,and liquid ring pumps.To put the re-lative pump sizes in perspective,attention is fixed on the rotors or reciprocating elements of PD pumps,just as impellers indicate the sizes of rotodynamic pumps.The size of a PD pump is found from a dimensionless combination of displacement flow rate,rotative speed and diameter.The flow rate, head (or pressure rise)and power are related through the component efficiencies.The cavitation coef-ficient,often close to unity,connects the rotor tip speed or piston speed with the required NPSH, which can also be affected by the pressure rise of the pump due to leakage across the internal clea-rances.Operational effects due to cavitation,ingestion of gas or abrasives,and viscous and non-New-tonian fluids are discussed.

  1. A geometrical introduction to screw theory

    Minguzzi, E.


    This work introduces screw theory, a venerable but little known theory aimed at describing rigid body dynamics. This formulation of mechanics unifies in the concept of screw the translational and rotational degrees of freedom of the body. It captures a remarkable mathematical analogy between mechanical momenta and linear velocities, and between forces and angular velocities. For instance, it clarifies that angular velocities should be treated as applied vectors and that, under the composition of motions, they sum with the same rules of applied forces. This work provides a short and rigorous introduction to screw theory intended for an undergraduate and general readership.

  2. Vertical-Screw-Auger Conveyer Feeder

    Walton, Otis (Inventor); Vollmer, Hubert J. (Inventor)


    A conical feeder is attached to a vertically conveying screw auger. The feeder is equipped with scoops and rotated from the surface to force-feed regolith the auger. Additional scoops are possible by adding a cylindrical section above the conical funnel section. Such then allows the unit to collect material from swaths larger in diameter than the enclosing casing pipe of the screw auger. A third element includes a flexible screw auger. All three can be used in combination in microgravity and zero atmosphere environments to drill and recover a wide area of subsurface regolith and entrained volatiles through a single access point on the surface.

  3. A Biomechanical Comparison of Expansive Pedicle Screws for Severe Osteoporosis: The Effects of Screw Design and Cement Augmentation.

    Ching-Lung Tai

    Full Text Available Expansive pedicle screws significantly improve fixation strength in osteoporotic spines. However, the previous literature does not adequately address the effects of the number of lengthwise slits and the extent of screw expansion on the strength of the bone/screw interface when expansive screws are used with or without cement augmentation. Herein, four designs for expansive pedicle screws with different numbers of lengthwise slits and different screw expansion levels were evaluated. Synthetic bones simulating severe osteoporosis were used to provide a comparative platform for each screw design. The prepared specimens were then tested for axial pullout failure. Regardless of screw design, screws with cement augmentation demonstrated significantly higher pullout strength than pedicle screws without cement augmentation (p 0.05. Taken together, our results show that pedicle screws combined with cement augmentation may greatly increase screw fixation regardless of screws with or without expansion. An increase in both the number of slits and the extent of screw expansion had little impact on the screw-anchoring strength. Cement augmentation is the most influential factor for improving screw pullout strength.

  4. Rotary Engine Friction Test Rig Development Report


    5  4.  Friction Rig Development 7  5.  AutoCAD ...Figure 4. Engine friction test rig AutoCAD model. ........................................................................8  Figure 5. dead center. 8 5. AutoCAD Model Development A model of the rotary engine friction test rig was developed to determine the optimal

  5. Conceptual Study of Rotary-Wing Microrobotics


    xx  I.  Introduction ...Edge TPV Thermo-Photovoltaic CONCEPTUAL STUDY OF ROTARY-WING MICROROBOTICS I. Introduction Flying micro-robots offer unimaginable military...Tweezers 1989 1 cm3 inch robot 1991 Magnetostrictive mover in pipe 1992 Insect-based robot 1993 Ciliary-motion conveyor 1994 Pipe inspection robot

  6. Numerical Modeling of Rotary Kiln Productivity Increase

    Romero-Valle, M.A.; Pisaroni, M.; Van Puyvelde, D.; Lahaye, D.J.P.; Sadi, R.


    Rotary kilns are used in many industrial processes ranging from cement manufacturing to waste incineration. The operating conditions vary widely depending on the process. While there are many models available within the literature and industry, the wide range of operating conditions justifies furthe

  7. Deformation analysis of rotary combustion engine housings

    Vilmann, Carl


    This analysis of the deformation of rotary combustion engine housings targeted the following objectives: (1) the development and verification of a finite element model of the trochoid housing, (2) the prediction of the stress and deformation fields present within the trochoid housing during operating conditions, and (3) the development of a specialized preprocessor which would shorten the time necessary for mesh generation of a trochoid housing's FEM model from roughly one month to approximately two man hours. Executable finite element models were developed for both the Mazda and the Outboard Marine Corporation trochoid housings. It was also demonstrated that a preprocessor which would hasten the generation of finite element models of a rotary engine was possible to develop. The above objectives are treated in detail in the attached appendices. The first deals with finite element modeling of a Wankel engine center housing, and the second with the development of a preprocessor that generates finite element models of rotary combustion engine center housings. A computer program, designed to generate finite element models of user defined rotary combustion engine center housing geometries, is also included.

  8. Development of a novel rotary magnetic refrigerator

    Lozano, Jaime A.; Capovilla, Matheus S.; Trevizoli, Paulo V.


    A novel rotary magnetic refrigerator was designed and built at the Federal University of Santa Catarina (UFSC). The optimized magnetic circuit is a two-pole system in a rotor-stator configuration with high flux density regions of approximately 1 T. Eight pairs of stationary regenerator beds filled...

  9. Counteracting ring formation in rotary kilns

    Pisaroni, M.; Sadi, R.; Lahaye, D.

    Avoiding the formation of rings in rotary kilns is an issue of primary concern to the cement production industry. We developed a numerical combustion model that revealed that in our case study rings are typically formed in zones of maximal radiative heat transfer. This local overheating causes the o

  10. The performance of rotary power tiller using prototype rotary blades in dry-land field

    Sirisak Chertkiattipol


    Full Text Available The effect of shape of prototype rotary blades on the performance of rotary power tiller was investigated in this study. Three sets of rotors, i.e. 14-blade rotor of the Japanese C-shape blade (4.5 cm tilling width of one blade; T1, 14-blade rotor of the prototype rotary blade no. 1 (4.5 cm tilling width of one blade; T2, and 10-blade rotor of the prototype rotary blade no. 2 (6.5 cm tilling width of one blade; T3 were used. The tests were conducted in a dry-land field of clay loam with soil moisture content of 16.04 % (d.b. and dry bulk density of 1.51 g/cm3 at different rotational speeds of 300, 350 and 400 rpm at one and two tilling passes. For all rotors, experimental results showed that the mean soil clod diameter decreased and soil inversion increased with increasing rotational speed of the rotor. The mean soil clod diameter decreased at pass 2. Soil inversion during pass 2 was higher than pass 1. However, the three sets of rotors showed no significant difference on mean soil clod diameter and soil inversion. The shape of blade prototype rotary blade no. 1 and the decreasing number of prototype rotary blade no. 2 did not affect the tillage performance as compared with the Japanese C-shaped blade.

  11. Twin Screw Mixer/Fine Grind Facility

    Federal Laboratory Consortium — The 40-mm Twin-Screw Mixer/Extruder (TSE) pilot plant is a continuous, remotely operated, flexible facility that can significantly enhance safety and environmental...

  12. Determinación de perfiles para rotores de compresores de tornillo con perfil simétrico. // Profiles determination for screw compressors rotors with symmetrical profile.

    A. Rivera Torres


    Full Text Available Los compresores rotativos de tornillo, constituyeron el acontecimiento histórico más relevante del siglo XX en el campodel proceso de compresión. Dentro de los elementos fundamentales de los compresores rotativos de tornillo se encuentranlos rotores, los cuales tienen lóbulos o canales helicoidales con perfiles con formas simétricas o asimétricas.En este articulo se presenta un método para el diseño de los perfiles de rotores para compresores o bombas de tornillo, conperfil circular, a partir del empleo de una curva de cuarto orden y la condición de conjugación de los engranajes, sin incluirel empleo de cicloides en la generación de dichos perfiles, lográndose características similares a la de los perfiles SRM.Palabras claves: Rotores, rotor macho, rotor hembra._____________________________________________________________________________Abstract:Rotary screw compressors constitute the most relevant historic event of the twentieth century in the field of the process ofcompression. The most fundamental elements of rotary screw compressors are the rotors, which have helical lobes or canalsand symmetrical or asymmetrical profiles.This paper presents a method of circular profile design for screw compressors or pumps, based on fourth order curves andthe conjugation of gears, which does not include the application of cycloids in profile generation but have similarcharacteristics to SRM profiles.Key words: rotors, male rotor, female rotor.

  13. Design and biomechanical study of a modified pedicle screw

    LIU Tao; ZHENG Wen-jie; LI Chang-qing; LIU Guo-dong; ZHOU Yue


    Objective: In pedicle screw fixation,the heads of monoaxial screws need to be directed in the same straight line to accommodate the rod placement by backing out during operation, which decreases the insertional torque and internal fixation strength. While polyaxial screws facilitate the assembly of the connecting rod, but its ball-in-cup locking mechanism reduces the static compressive bending yield strength as compared with monoaxial screws. Our study aimed to assess the mechanical performance of a modified pedicle screw.Methods: In this study, the tail of the screw body of the modified pedicle screw was designed to be a cylindershaped structure that well matched the inner wall of the screw head and the screw head only rotated around the cyclinder. Monoaxial screws, modified screws and polyaxial screws were respectively assembled into 3 groups ofvertebrectomy models simulated by ultra high molecular weight polyethylene (UHMWPE) blocks. This model was developed according to a standard for destructive mechanical testing published by the American Society for Testing Materials (ASTM F1717-04). Each screw design had 6 subgroups, including 3 for static tension, load compression and torsion tests, and the rest for dynamic compression tests. In dynamic tests, the cyclic loads were 25%, 50%, and 75% of the compressive bending ultimate loads respectively.Yield load, yield ultimate load, yield stiffness, torsional stiffness, cycles to failure and modes of failure for the 3 types of screws were recorded. The results of modified screws were compared with those ofmonoaxial and polyaxial screws.Results: In static tests, results of bending stiffness,yield load, yield torque and torsional stiffness indicated no significant differences between the modified and monoaxial screws (P>0.05), but both differed significantly from those ofpolyaxial screws (P<0.05). In dynamic compression tests,both modified and monoaxial screws showed failures that occurred at the insertion point of screw

  14. Ball Screw Actuator Including a Stop with an Integral Guide

    Wingett, Paul T. (Inventor); Perek, John (Inventor); Geck, Kellan (Inventor)


    An actuator includes a housing assembly, a ball nut, a ball screw, and a ball screw stop. The ball nut is rotationally mounted in the housing assembly, is adapted to receive an input torque, and is configured, upon receipt thereof, to rotate and supply a drive force. The ball screw is mounted within the housing assembly and extends through the ball nut. The ball screw has a first end and a second end, and is coupled to receive the drive force from the ball nut. The ball screw is configured, upon receipt of the drive force, to selectively translate between a stow position and a deploy position. The ball screw stop is mounted on the ball screw to translate therewith and is configured to at selectively engage the housing assembly while the ball screw is translating, and engage the ball nut when the ball screw is in the deploy position.

  15. Non-contact magnetically coupled rectilinear-rotary oscillations to exploit low-frequency broadband energy harvesting with frequency up-conversion

    Deng, Wei; Wang, Ya


    Ambient vibrations have a rectilinear and broadband nature and are particularly rich in the low-frequency regions. This letter reports an electromagnetic energy harvester to transform low-frequency broadband rectilinear vibrations into electricity with frequency up-conversion. The harvester consists of a rectilinear oscillator and a rotary oscillator coupled through magnetic force induced by four arc permanent magnets centrosymmetrically distributed on each oscillator. The rotary oscillator also includes two repulsive magnets and six stationary coils with steel screws inside to obtain and maintain four equilibrium positions with shallowed potential wells. The magnetic interaction between the rectilinear oscillator and the rotary oscillator is formulated using a magnetic dipole model. The restoring torque induced by the steel screws on the rotor is experimentally measured. Magnetically coupled governing equations are derived and their numerical solutions are used to characterize the dynamic response of the harvester under chirp excitations. Experimental results demonstrate its excellent harvesting capability of scavenging low-frequency wideband vibrational energy under slow-frequency-drifted excitations, simple harmonic excitations, and mixed-frequency excitations. Under harmonic excitations, the rectilinear oscillator vibrates non-harmonically but approximately periodically, while the rotary counterpart oscillates in a more complex pattern varying with the excitation frequency, which leads to the frequency up-conversion (up to 10 times increase) and broadened bandwidth (25% increase from its resonant frequency). Experiments show an output voltage of 5 V (RMS)/40 V (Peak to Peak) and an output power of 55 mW (RMS)/950 mW (Peak) at an optimal load of 465 Ω under harmonic excitation of 4 Hz at 0.7 g.

  16. Flow characteristics of screws and special mixing enhancers in a co-rotating twin screw extruder

    Brouwer, T.; Todd, D.B.; Janssen, L.P.B.M.


    The flow behavior of a Newtonian fluid through special mixing enhancers in a modular intermeshing co-rotating twin screw extruder has been examined. The mixing enhancers are slotted screws and gear mixing elements. Particular attention has been directed to drag and pressure flow characteristics and

  17. Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling

    Lee Yen-Chen


    Full Text Available Abstract Background Pedicle screws with PMMA cement augmentation have been shown to significantly improve the fixation strength in a severely osteoporotic spine. However, the efficacy of screw fixation for different cement augmentation techniques, namely solid screws with retrograde cement pre-filling versus cannulated screws with cement injection through perforation, remains unknown. This study aimed to determine the difference in pullout strength between conical and cylindrical screws based on the aforementioned cement augmentation techniques. The potential loss of fixation upon partial screw removal after screw insertion was also examined. Method The Taguchi method with an L8 array was employed to determine the significance of design factors. Conical and cylindrical pedicle screws with solid or cannulated designs were installed using two different screw augmentation techniques: solid screws with retrograde cement pre-filling and cannulated screws with cement injection through perforation. Uniform synthetic bones (test block simulating severe osteoporosis were used to provide a platform for each screw design and cement augmentation technique. Pedicle screws at full insertion and after a 360-degree back-out from full insertion were then tested for axial pullout failure using a mechanical testing machine. Results The results revealed the following 1 Regardless of the screw outer geometry (conical or cylindrical, solid screws with retrograde cement pre-filling exhibited significantly higher pullout strength than did cannulated screws with cement injection through perforation (p = 0.0129 for conical screws; p = 0.005 for cylindrical screws. 2 For a given cement augmentation technique (screws without cement augmentation, cannulated screws with cement injection or solid screws with cement pre-filling, no significant difference in pullout strength was found between conical and cylindrical screws (p >0.05. 3 Cement infiltration into the open cell of

  18. Equivalent dynamic model of DEMES rotary joint

    Zhao, Jianwen; Wang, Shu; Xing, Zhiguang; McCoul, David; Niu, Junyang; Huang, Bo; Liu, Liwu; Leng, Jinsong


    The dielectric elastomer minimum energy structure (DEMES) can realize large angular deformations by a small voltage-induced strain of the dielectric elastomer (DE), so it is a suitable candidate to make a rotary joint for a soft robot. Dynamic analysis is necessary for some applications, but the dynamic response of DEMESs is difficult to model because of the complicated morphology and viscoelasticity of the DE film. In this paper, a method composed of theoretical analysis and experimental measurement is presented to model the dynamic response of a DEMES rotary joint under an alternating voltage. Based on measurements of equivalent driving force and damping of the DEMES, the model can be derived. Some experiments were carried out to validate the equivalent dynamic model. The maximum angle error between model and experiment is greater than ten degrees, but it is acceptable to predict angular velocity of the DEMES, therefore, it can be applied in feedforward-feedback compound control.

  19. A new spin on the rotary engine

    Ashley, S.


    This article reports on a Canadian company that is trying to develop high-power, low-weight motors based on a novel axial-vane rotary engine concept. A promising new attempt at a practical rotary engine is the Rand Cam engine now being developed by Reg Technologies Inc. The Rand Cam engine is a four-stroke, positive-displacement power plant based on an axial-vane compression/expansion mechanism with only nine moving parts (eight vanes and a rotor). The new engine design uses passive ports rather than mechanically operated valves, and it features lighter-weight reciprocating parts than customary pistons. The Rand Cam operates at lower speeds than a typical Wankel engine (less than 2,000 rpm) and at higher compression ratios. Chamber sealing is accomplished using sliding axial vanes rather than the motion of an eccentric rotor.

  20. Rotary-scanning optical resolution photoacoustic microscopy

    Qi, Weizhi; Xi, Lei


    Optical resolution photoacoustic microscopy (ORPAM) is currently one of the fastest evolving photoacoustic imaging modalities. It has a comparable spatial resolution to pure optical microscopic techniques such as epifluorescence microscopy, confocal microscopy, and two-photon microscopy, but also owns a deeper penetration depth. In this paper, we report a rotary-scanning (RS)-ORPAM that utilizes a galvanometer scanner integrated with objective to achieve rotary laser scanning. A 15 MHz cylindrically focused ultrasonic transducer is mounted onto a motorized rotation stage to follow optical scanning traces synchronously. To minimize the loss of signal to noise ratio, the acoustic focus is precisely adjusted to reach confocal with optical focus. Black tapes and carbon fibers are firstly imaged to evaluate the performance of the system, and then in vivo imaging of vasculature networks inside the ears and brains of mice is demonstrated using this system.

  1. Rotary Mode Core Sample System availability improvement

    Jenkins, W.W.; Bennett, K.L.; Potter, J.D. [Westinghouse Hanford Co., Richland, WA (United States); Cross, B.T.; Burkes, J.M.; Rogers, A.C. [Southwest Research Institute (United States)


    The Rotary Mode Core Sample System (RMCSS) is used to obtain stratified samples of the waste deposits in single-shell and double-shell waste tanks at the Hanford Site. The samples are used to characterize the waste in support of ongoing and future waste remediation efforts. Four sampling trucks have been developed to obtain these samples. Truck I was the first in operation and is currently being used to obtain samples where the push mode is appropriate (i.e., no rotation of drill). Truck 2 is similar to truck 1, except for added safety features, and is in operation to obtain samples using either a push mode or rotary drill mode. Trucks 3 and 4 are now being fabricated to be essentially identical to truck 2.

  2. Standard Waste Box Lid Screw Removal Option Testing

    Anast, Kurt Roy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)


    This report provides results from test work conducted to resolve the removal of screws securing the standard waste box (SWB) lids that hold the remediated nitrate salt (RNS) drums. The test work evaluated equipment and process alternatives for removing the 42 screws that hold the SWB lid in place. The screws were secured with a red Loctite thread locker that makes removal very difficult because the rivets that the screw threads into would slip before the screw could be freed from the rivet, making it impossible to remove the screw and therefore the SWB lid.

  3. Precision Model for Microwave Rotary Vane Attenuator

    Guldbrandsen, Tom


    A model for a rotary vane attenuator is developed to describe the attenuator reflection and transmission coefficients in detail. All the parameters of the model can be measured in situ, i.e., without diassembling any part. The tranmission errors caused by internal reflections are calculated from ...... measurements of the much larger reflection parameters, hence commonly used nonprecision instruments can be used to determine the transmission errors with sufficient accuracy for the highest precision obtainable in standard laboratories....

  4. Control of Rotary Cranes Using Fuzzy Logic

    Amjed A. Al-mousa


    Full Text Available Rotary cranes (tower cranes are common industrial structures that are used in building construction, factories, and harbors. These cranes are usually operated manually. With the size of these cranes becoming larger and the motion expected to be faster, the process of controlling them has become difficult without using automatic control methods. In general, the movement of cranes has no prescribed path. Cranes have to be run under different operating conditions, which makes closed-loop control attractive.

  5. Numerical Modeling of Rotary Kiln Productivity Increase


    Rotary kilns are used in many industrial processes ranging from cement manufacturing to waste incineration. The operating conditions vary widely depending on the process. While there are many models available within the literature and industry, the wide range of operating conditions justifies further modeling work to improve the understanding of the processes taking place within the kiln. The kiln being studied in this work produces calcium aluminate cements (CAC). In a first stage of the pro...

  6. Maintenance cost study of rotary wing aircraft


    The feasibility was studied of predicting rotary wing operation maintenance costs by using several aircraft design factors for the aircraft dynamic systems. The dynamic systems considered were engines, drives and transmissions, rotors, and flight controls. Multiple regression analysis was used to correlate aircraft design and operational factors with manhours per flight hour, and equations for each dynamic system were developed. Results of labor predictions using the equations compare favorably with actual values.

  7. Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated polyaxial screw system

    Lutz Weise


    Full Text Available Lutz Weise, Olaf Suess, Thomas Picht, Theodoros KombosNeurochirurgische Klinik, Charité – Universitätsmedizin Berlin, Berlin, GermanyObjective: Transpedicular screws are commonly and successfully used for posterior fixation in spinal instability, but their insertion remains challenging. Even using navigation techniques, there is a misplacement rate of up to 11%. The aim of this study was to assess the accuracy of a novel pedicle screw system.Methods: Thoracic and lumbar fusions were performed on 67 consecutive patients for tumor, trauma, degenerative disease or infection. A total of 326 pedicular screws were placed using a novel wire-guided, cannulated, polyaxial screw system (XIA Precision®, Stryker. The accuracy of placement was assessed post operatively by CT scan, and the patients were followed-up clinically for a mean of 16 months.Results: The total medio-caudal pedicle wall perforation rate was 9.2% (30/326. In 19 of these 30 cases a cortical breakthrough of less than 2 mm occurred. The misplacement rate (defined as a perforation of 2 mm or more was 3.37% (11/326. Three of these 11 screws needed surgical revision due to neurological symptoms or CSF leakage. There have been no screw breakages or dislocations over the follow up-period.Conclusion: We conclude that the use of this cannulated screw system for the placement of pedicle screws in the thoracic and lumbar spine is accurate and safe. The advantages of this technique include easy handling without a time-consuming set up. Considering the incidence of long-term screw breakage, further investigation with a longer follow-up period is necessary.Keywords: spinal instrumentation, pedicle screws, misplacement, pedicle wall perforation

  8. The Wankel rotary engine a history

    Hege, John B


    "It stands apart from the crowd as the only history of the Wankel rotary engine that brings the story into the 21st Century"--SAH Journal; "this book continues to excel...terrific...technophiles will love this"--Hemmings Motor News; "excellent"--Hemmings Sports & Exotic Car; "a complete history...guaranteed to delight"--Old Cars Weekly; "definitive…a must-read"--Choice; "informative"--SciTech Book News; "goes a long way to explaining everything"--The Automobile. This complete and well-illustrated account traces the full history of the Wankel rotary engine and its use in various cars, motorcycles, snowmobiles and other applications. It clearly explains the working of the engine and the technical challenges it presented--the difficulty of designing effective and durable seals, early emissions troubles, high fuel consumption, and others. The work done by several companies to overcome these problems is described in detail, as are the economic and political troubles that nearly killed the rotary in the 19...

  9. Innovative collaboration important to rotary steerable drilling



    Sperry-Sun Drilling Services' recently commercialized Geo-Pilot{sup T}M rotary steerable drilling system is described. The system consists of the Geo-Pilot{sup T}M rotary steerable tool, a logging-while-drilling (LWD) system, specially designed long-gauge bits and the INSITE{sup T}M data acquisition and management system. The system brings a completely new approach to rotary steerable drilling. It uses 'point-the-bit' technology to deflect a rotating drive shaft off center, causing the drive shaft to flex and alter the direction of the drilling. The tool provides real-time steering information and at-bit inclination measurement, both of which are integrated with the INSITE{sup T}M rig information system. The real-time data can be displayed along with other formation evaluation information. The system has been evaluated at the Gas Research Institute's Oklahoma test facility; it has been used commercially by Canadian, Norwegian and US operators, with complete success. Worldwide deployment of the system is in the planning stages.

  10. Rotary-Atomizer Electric Power Generator

    Nguyen, Trieu; Tran, Tuan; de Boer, Hans; van den Berg, Albert; Eijkel, Jan C. T.


    We report experimental and theoretical results on a ballistic energy-conversion method based on a rotary atomizer working with a droplet acceleration-deceleration cycle. In a rotary atomizer, liquid is fed onto the center of a rotating flat surface, where it spreads out under the action of the centrifugal force and creates "atomized" droplets at its edge. The advantage of using a rotary atomizer is that the centrifugal force exerted on the fluid on a smooth, large surface is not only a robust form of acceleration, as it avoids clogging, but also easily allows high throughput, and produces high electrical power. We successfully demonstrate an output power of 4.9 mW and a high voltage up to 3120 V. At present, the efficiency of the system is still low (0.14%). However, the conversion mechanism of the system is fully interpreted in this paper, permitting a conceptual understanding of system operation and providing a roadmap for system optimization. This observation will open up a road for building power-generation systems in the near future.


    S. L. Rovin


    Full Text Available Rotary tilting furnace (RTF is a new type of fuel furnaces, that provide the most efficient heating and recycling of polydisperse materials. The paper describes results of the investigations on thermal processes in the RTF, movement of materials and non-isothermal gas flow during kiln rotary process. The investigations have been carried out while using physical and computer simulations and under actual operating conditions applying the pilot plant. Results of the research have served as a basis for development of recommendations on the RTF calculations and designing and they have been also used for constructional design of a rotary tilting furnace for heating and melting of cast iron chips, reduction smelting of steel mill scale, melting of aluminum scrap, melting of lead from battery scrap. These furnaces have a high thermal efficiency (~50 %, technological flexibility, high productivity and profitability. Proven technical solutions for recycling of ferrous and non-ferrous metals develop the use of RTF in the foundry and metallurgical industry as the main technological unit for creation of cost-effective small-tonnage recycling of metal waste generated at the plants. The research results open prospects for organization of its own production for high-quality charging material in Belarus in lieu of imported primary metal. The proposed technology makes it possible to solve environmental challenge pertaining to liquidation of multi-tonnage heaps of metal-containing wastes.

  12. Twin screw wet granulation: Binder delivery.

    Saleh, Mohammed F; Dhenge, Ranjit M; Cartwright, James J; Hounslow, Michael J; Salman, Agba D


    The effects of three ways of binder delivery into the twin screw granulator (TSG) on the residence time, torque, properties of granules (size, shape, strength) and binder distribution were studied. The binder distribution was visualised through the transparent barrel using high speed imaging as well as quantified using offline technique. Furthermore, the effect of binder delivery and the change of screw configuration (conveying elements only and conveying elements with kneading elements) on the surface velocity of granules across the screw channel were investigated using particle image velocimetry (PIV). The binder was delivered in three ways; all solid binder incorporated with powder mixture, 50% of solid binder mixed with powder mixture and 50% mixed with water, all the solid binder dissolved in water. Incorporation of all solid binder with powder mixture resulted in the relatively longer residence time and higher torque, narrower granule size distribution, more spherical granules, weaker big-sized granules, stronger small-sized granules and better binder distribution compared to that in other two ways. The surface velocity of granules showed variation from one screw to another as a result of uneven liquid distribution as well as shown a reduction while introducing the kneading elements into the screw configuration.

  13. Tallinna Rotary klubi valis aasta politseiniku ja narkokoera


    Tallinna Rotary klubi autasustas parima narkopolitseiniku preemiaga Lõuna politseiprefektuuri narkokuritegude talituse vaneminspektorit Jarek Pavlihhinit ning parima narkokoera tiitliga vene spanjelit Allrighti

  14. The accuracy and the safety of individualized 3D printing screws insertion templates for cervical screw insertion.

    Deng, Ting; Jiang, Minghui; Lei, Qing; Cai, Lihong; Chen, Li


    Clinical trial for cervical screw insertion by using individualized 3-dimensional (3D) printing screw insertion templates device. The objective of this study is to evaluate the safety and accuracy of the individualized 3D printing screw insertion template in the cervical spine. Ten patients who underwent posterior cervical fusion surgery with cervical pedicle screws, laminar screws or lateral mass screws between December 2014 and December 2015 were involved in this study. The patients were examined by CT scan before operation. The individualized 3D printing templates were made with photosensitive resin by a 3D printing system to ensure the screw shafts entered the vertebral body without breaking the pedicle or lamina cortex. The templates were sterilized by a plasma sterilizer and used during the operation. The accuracy and the safety of the templates were evaluated by CT scans at the screw insertion levels after operation. The accuracy of this patient-specific template technique was demonstrated. Only one screw axis greatly deviated from the planned track and breached the cortex of the pedicle because the template was split by rough handling and then we inserted the screws under the fluoroscopy. The remaining screws were inserted in the track as preoperative design and the screw axis deviated by less than 2 mm. Vascular or neurologic complications or injuries did not happen. And no infection, broken nails, fracture of bone structure, or screw pullout occurred. This study verified the safety and the accuracy of the individualized 3D printing screw insertion templates in the cervical spine as a kind of intraoperative screw navigation. This individualized 3D printing screw insertion template was user-friendly, moderate cost, and enabled a radiation-free cervical screw insertion.

  15. [Cement augmentation of pedicle screws : Pros and cons].

    Schnake, K J; Blattert, T R; Liljenqvist, U


    Cement augmentation of pedicle screws biomechanically increases screw purchase in the bone. However, clinical complications may occur. The pros and cons of the technique are discussed from different clinical perspectives.

  16. Impact of screw configuration on the particle size distribution of granules produced by twin screw granulation.

    Vercruysse, J; Burggraeve, A; Fonteyne, M; Cappuyns, P; Delaet, U; Van Assche, I; De Beer, T; Remon, J P; Vervaet, C


    Twin screw granulation (TSG) has been reported by different research groups as an attractive technology for continuous wet granulation. However, in contrast to fluidized bed granulation, granules produced via this technique typically have a wide and multimodal particle size distribution (PSD), resulting in suboptimal flow properties. The aim of the current study was to evaluate the impact of granulator screw configuration on the PSD of granules produced by TSG. Experiments were performed using a 25 mm co-rotating twin screw granulator, being part of the ConsiGma™-25 system (a fully continuous from-powder-to-tablet manufacturing line from GEA Pharma Systems). Besides the screw elements conventionally used for TSG (conveying and kneading elements), alternative designs of screw elements (tooth-mixing-elements (TME), screw mixing elements (SME) and cutters) were investigated using an α-lactose monohydrate formulation granulated with distilled water. Granulation with only conveying elements resulted in wide and multimodal PSD. Using kneading elements, the width of the PSD could be partially narrowed and the liquid distribution was more homogeneous. However, still a significant fraction of oversized agglomerates was obtained. Implementing additional kneading elements or cutters in the final section of the screw configuration was not beneficial. Furthermore, granulation with only TME or SME had limited impact on the width of the PSD. Promising results were obtained by combining kneading elements with SME, as for these configurations the PSD was narrower and shifted to the size fractions suitable for tableting.

  17. A modified technique for removing a failed abutment screw from an implant with a custom guide tube.

    Taira, Yohsuke; Sawase, Takashi


    Fracture of abutment screw is a serious prosthodontic complication. When the abutment screw is fractured at the junction of the screw shank and screw thread, removal of the fractured screw fragment from the screw hole can be difficult. This article describes a modified technique for removing the failed abutment screw with a custom guide tube and tungsten carbide bur. The failed screw can be removed speedily without damaging the screw hole of the implant body or the screw threads.

  18. A processing method for orthodontic mini-screws reuse

    Saeed Noorollahian


    Conclusion: Cleaning of used mini-screws with phosphoric acid 37% (10 minutes and sodium hypochlorite 5.25% (30 minutes reduces tissue remnants to the level of as-received mini-screws. So it can be suggested as a processing method of used mini-screws. Previous insertion of mini-screws into the bone and above-mentioned processing method and resterilization with autoclave had no adverse effects on insertion, removal, and fracture torque values as mechanical properties indices.

  19. Guided pedicle screw insertion: techniques and training.

    Manbachi, Amir; Cobbold, Richard S C; Ginsberg, Howard J


    In spinal fusion surgery, the accuracy with which screws are inserted in the pedicle has a direct effect on the surgical outcome. Accurate placement generally involves considerable judgmental skills that have been developed through a lengthy training process. Because the impact of misaligning one or more pedicle screws can directly affect patient safety, a number of navigational and trajectory verification approaches have been described and evaluated in the literature to provide some degree of guidance to the surgeon. To provide a concise review to justify the need and explore the current state of developing navigational or trajectory verification techniques for ensuring proper pedicle screw insertion along with simulation methods for better educating the surgical trainees. Recent literature review. To justify the need to develop new methods for optimizing pedicle screw paths, we first reviewed some of the recent publications relating to the statistical outcomes for different types of navigation along with the conventional freehand (unassisted) screw insertion. Second, because of the importance of providing improved training in the skill of accurate screw insertion, the training aspects of relevant techniques are considered. The third part is devoted to the description of specific navigational assist methods or trajectory verification techniques and these include computer-assisted navigation, three-dimensional simulations, and also electric impedance and optical and ultrasonic image-guided methods. This article presents an overview of the need and the current status of the guidance methods available for improving the surgical outcomes in spinal fusion procedures. It also describes educational aids that have the potential for reducing the training process. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Twin screw extrusion of kodo millet-chickpea blend: process parameter optimization, physico-chemical and functional properties.

    Geetha, R; Mishra, H N; Srivastav, P P


    Kodo millet-chickpea flour blend (70:30) was explored for development of directly expanded snack by twin-screw extrusion. Effect of process parameters like temperature (80-150 °C), screw speed (250-300 rpm) and feeder speed (15-30 rpm) on physical properties (expansion ratio, bulk density, hardness, crispiness) of extrudates were investigated and optimized using response surface methodology. Desirable crispy extrudates were obtained at higher screw speed 293 rpm, lower feeder speed 19 rpm, and medium to high temperature of 123 °C. Effect of extreme and intermediate process conditions on functional, proximate quality and colour of the extrudates were also evaluated.

  1. Drag and Torque on Locked Screw Propeller

    Tomasz Tabaczek


    Full Text Available Few data on drag and torque on locked propeller towed in water are available in literature. Those data refer to propellers of specific geometry (number of blades, blade area, pitch and skew of blades. The estimation of drag and torque of an arbitrary propeller considered in analysis of ship resistance or propulsion is laborious. The authors collected and reviewed test data available in the literature. Based on collected data there were developed the empirical formulae for estimation of hydrodynamic drag and torque acting on locked screw propeller. Supplementary CFD computations were carried out in order to prove the applicability of the formulae to modern moderately skewed screw propellers.

  2. Screw Extruder for Pellet Injection System

    Sharadkumar K. Chhantbar


    Full Text Available Solid hydrogenic pellets are used as fuel for fusion energy reactor. A technique for continuous production of solid hydrogen and its isotopes by a screw extruder is suggested for the production of an unlimited number of pellets. The idea was developed and patented by PELIN laboratories, Inc. (Canada. A Gifford McMahon cryocooler is used for the generation of solid hydrogenic fluid pellets. Requirements of the pellets is depends upon the energy to be produced by tokamak. This review paper focuses on the model for the screw extruder for solidification of hydrogen ice having high injection reliability.

  3. A geometrical introduction to screw theory

    Minguzzi, E


    Since the addition of applied forces must take into account the line of action, applied forces do not belong to a vector space. Screw theory removes this geometrical limitation and solves other mechanical problems by unifying, in a single concept, the translational and rotational degrees of freedom. Although venerable this theory is little known. By introducing some innovations, I show how screw theory can help us to rapidly develop several standard and less standard results in classical mechanics. The connection with the Lie algebra of the group of rigid maps is clarified.

  4. Biomechanical evaluation of an expansive pedicle screw in calf vertebrae

    雷伟; 吴子祥


    Objective: To obtain a comprehensive understanding of the effect of the improvement of fixation strength of a newly designed expansive pedicle screw through biomechanical analyses.Metheds: 100 (200 pedicles) fresh calf lumber vertebrae were used. A total of four instrumentation systems were tested including CDH (CD Horizon), USS (Universal Spine System pedicle screw), Tenor (Sofamor Denek) and expansive pedicle screw (EPS). Pullout and turning-back tests were performed to compare the holding strength of the expansive pedicle screw with conventional screws, i.e. USS, CDH and Tenor. Revision tests were performed to evaluate the mechanical properties of the expansive pedicle screw as a "rescue" revision screw. A fatigue simulation using perpendicular load up to 1 500 000 cycles was carried out.Results: The turning back torque (Tmax) and pull-out force (Fmax) of EPS were significantly greater than those of USS, Tenor and CDH screws (6.5 mm×40 mm). In revision tests, the Fmax of both kinds of EPS (6.5 mm×40 mm; 7.0 mm×40 mm) were greater than that of CDH, USS and Tenor screws significantly (P<0.05). No screws were broken or bent at the end of fatigue tests.Conclusions: EPS can significantly improve the bone purchase and the pull-out strength compared to USS, Tenor and CDH screws with similar dimensions before and after failure simulation. The fatigue characteristic of EPS is similar to that of CDH, USS and Tenor screws.

  5. Dual-worm screw compressors; Compresseurs bi-vis

    Baleydier, J.P. [Bitzer France, 69 - Lyon (France)


    Low power worm-screw moto-compressors are used in any king of refrigerating machineries and more and more in air conditioning systems. This paper presents the principle of dual-screw moto-compressors: worm-screw technology, role of oil (lubrication, tightness, cooling), compression, internal pressure, power reduction, lubrication, economizer, operation, model selection and accessories. (J.S.)

  6. 21 CFR 872.4880 - Intraosseous fixation screw or wire.


    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraosseous fixation screw or wire. 872.4880... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4880 Intraosseous fixation screw or wire. (a) Identification. An intraosseous fixation screw or wire is a metal device intended to be...

  7. The additon of screws and the axodes of gear pairs

    ZHANG Wen-xiang


    In the light of screw addition, the distribution of instantaneous axes along the common perpendicular of the two screws is determined and all possible sorts of axodes are derived cinematically with the pitch of the relative-motio n screw in the gear pair as the basis and the transmission ratio i as an inde pendent variable.

  8. The additon of screws and the axodes of gear pairs



    In the light of screw addition, the distribution of instantaneous axes along the common perpendicular of the two screws is determined and all possible sorts of axodes are derived cinematically with the pitch of the relative-motion screw in the gear pair as the basis and the transmission ratio i as an independent variable.

  9. Design of a magnetic lead screw for wave energy conversion

    Holm, Rasmus Koldborg; Berg, Nick Ilsø; Rasmussen, Peter Omand


    This paper deals with the development of a magnetic lead screw (MLS) for wave energy conversion. Initially, a brief state-of-the-art regarding linear PM generators and magnetic lead screws is given, leading to an introduction of the magnetic lead screw and a presentation of the results from...

  10. A Novel Pedicle Screw with Mobile Connection: A Pilot Study

    Yasuaki Tokuhashi


    Full Text Available To prevent adjacent disc problems after spinal fusion, a pedicle screw with a mobile junction between the head and threaded shaft was newly developed. The threaded shaft of the screw has 10 degrees mobility in all directions, but its structure is to prevent abnormal translation and tilting. This screw was evaluated as follows: (1 endurance test: 106 times rotational stress was applied; (2 biological reactions: novel screws with a mobile head and conventional screws with a fixed head were inserted into the bilateral pedicles of the L3, L4, and L5 in two mini pigs with combination. Eight months after surgery, vertebral units with the screw rod constructs were collected. After CT scan, the soft and bony tissues around the screws were examined grossly and histologically. As a result, none of the screws broke during the endurance test stressing. The mean amount of abrasion wear was 0.0338 g. In the resected mini pig section, though zygapophyseal joints between fixed-head screws showed bony union, the amount of callus in the zygapophyseal joints connected with mobile-head screws was small, and joint space was confirmed by CT. No metalloses were noted around any of the screws. Novel screws were suggested to be highly durable and histologically safe.

  11. Resolving Two Dimensional Angular Velocity within a Rotary Tumbler

    Helminiak, Nathaniel; Helminiak, David; Cariapa, Vikram; Borg, John


    In this study, a horizontally oriented cylindrical tumbler, filled at variable depth with cylindrical media, was rotated at various constant speeds. A monoplane layer of media was photographed with a high-speed camera and images were post processed with Particle Tracking Velocimetry (PTV) algorithms in order to resolve both the translational and rotational flow fields. Although the translational velocity fields have been well characterized, contemporary resources enabled the ability to expand upon and refine data regarding rotational characteristics of particles within a rotary tumbler. The results indicate that particles rotate according to intermittent no-slip interactions between the particles and solid body rotation. Particles within the bed, not confined to solid body rotation, exhibited behavior indicative of gearing between particles; each reacting to the tangential component of contact forming rotation chains. Furthermore, it was observed that solid body interactions corresponded to areas of confined motion, as areas of high interaction dissuaded no-slip rotation, while areas of developing flow tended towards no-slip rotation. Special thanks to: NASA Wisconsin Space Grant Consortium Program as well as Marquette University OPUS College of Engineering.

  12. Improvement of the Long-Screw in Single Screw Extruder%单螺杆挤压机中长螺杆的改进



    Researching on the long-screw of widespread used single screw extruder domestic market, the paper proposed a structure of new screw components with changing pitch, the process eliminates the need of electricity heating device for the original use to conserve energy, and facilitate production. The product quality of extrusion expanded food is better than before, the output per hour is increased twice. [Ch,2 fig. 1 tab. 13 ref. ]%对现有国内普遍使用的单螺杆挤压机中的长螺杆进行改进研究,提出一种带有交变螺距的螺杆组件结构,改进后的单螺杆挤压机省去了原来利用电能加热的装置,达到节约能源、方便生产,用此机组生产出的挤压膨化食品膨化效果优于未改进前,每小时的班产量是未改进前的3倍.

  13. Clinical pedicle screw accuracy and deviation from planning in robot-guided spine surgery: robot-guided pedicle screw accuracy

    Dijk, van Joris D.; Ende, Roy P.J.; Stramigioli, Stefano; Köchling, Matthias; Höss, Norbert


    STUDY DESIGN: A retrospective chart review was performed for 112 consecutive minimally invasive spinal surgery patients who underwent pedicular screw fixation in a community hospital setting. OBJECTIVE: To assess the clinical accuracy and deviation in screw positions in robot-assisted pedicle screw

  14. Design Robust Controller for Rotary Kiln

    Omar D. Hernández-Arboleda


    Full Text Available This paper presents the design of a robust controller for a rotary kiln. The designed controller is a combination of a fractional PID and linear quadratic regulator (LQR, these are not used to control the kiln until now, in addition robustness criteria are evaluated (gain margin, phase margin, strength gain, rejecting high frequency noise and sensitivity applied to the entire model (controller-plant, obtaining good results with a frequency range of 0.020 to 90 rad/s, which contributes to the robustness of the system.

  15. Static Model of Cement Rotary Kiln

    Omar D. Hernández-Arboleda


    Full Text Available In this paper, a static model of cement rotary kilns is proposed. The system model is obtained through polynomial series. The proposed model is contrasted with data of a real plant, where optimal results are obtained. Expected results are measured with respect to the clinker production and the combustible consumption is measured in relation with the consumption calorific. The expected result of the approach is the increase of the profitability of the factory through the decrease of the consumption of the combustible.

  16. Modelling and optimization of rotary parking system

    Skrzyniowski, A.


    The increasing number of vehicles in cities is a cause of traffic congestion which interrupts the smooth traffic flow. The established EU policy underlines the importance of restoring spaces for pedestrian traffic and public communication. The overall vehicle parking process in some parts of a city takes so much time that it has a negative impact on the environment. This article presents different kinds of solution with special focus on the rotary parking system (PO). This article is based on a project realized at the Faculty of Mechanical Engineering of Cracow University of Technology.

  17. New Imaging Spectrometric Method for Rotary Object

    方俊永; 赵达尊; 蒋月娟; 楚建军


    A new technique for imaging spectrometer for rotary object based on computed-tomography is proposed. A discrete model of this imaging spectrometric system is established, which is accordant to actual measurements and convenient for computation. In computer simulations with this method, projections of the object are detected by CCD while the object is rotating, and the original spectral images are numerically reconstructed from them by using the algorithm of computed-tomography. Simulation results indicate that the principle of the method is correct and it performs well for both broadband and narrow-band spectral objects.

  18. Light-driven rotary molecular motors : an ultrafast optical study

    Augulis, Ramunas; Klok, Martin; Loosdrecht, Paul H.M. van; Feringa, Bernard


    Molecular rotary motors, though common in nature, were first synthesized rather recently. One of the most promising categories of light-driven rotary molecular motors which allow for optical control is based on helical overcrowded alkenes. In this category of motors, the rotation of the motor’s roto

  19. Streaming current of a rotary atomizer for energy harvesting

    Nguyen, Trieu; de Boer, Hans L.; Tran, T.; van den Berg, Albert; Eijkel, Jan C.T.; Zengerle, R.


    We present the experimental results of an energy conversion system based on a rotary atomizer and the streaming current phenomenon. The advantage of using a rotary atomizer instead of a channel or membrane micropore as in conventional pressure-driven approached is that the centrifugal force exerted

  20. Streaming current of a rotary atomizer for energy harvesting

    Nguyen, Trieu; Boer, de H.; Tran, T.; Berg, van den A.; Eijkel, J.C.T.; Zengerle, R.


    We present the experimental results of an energy conversion system based on a rotary atomizer and the streaming current phenomenon. The advantage of using a rotary atomizer instead of a channel or membrane micropore as in conventional pressure-driven approached is that the centrifugal force exerted

  1. Percutaneous transluminal coronary rotary ablation with rotablator (European experience)

    M.E. Bertrand (Michel); J.M. Lablanche (Jean Marc); C. Bauters; P.P.T. de Jaegere (Peter); P.W.J.C. Serruys (Patrick); J. Meyer (Jurgen); U. Dietz; R. Erbel (Raimund)


    textabstractThis study reports the results from 3 European centers using rotary ablation with Rotablator, a device that is inserted into the coronary artery and removes atheroma by grinding it into millions of tiny fragments. Rotary ablation was performed in 129 patients. Primary success (reduction

  2. Engineering analysis of a rotary dryer: drying of wood particles

    Kamke, F.A.


    Rotary dryers are the most commonly used wood drying system in the particleboard industry. These dryers also play an increasingly important role in drying wood residues for fuel. A rotary dryer simulation model was developed, in the form of a computer program, for the purpose of analyzing the drying behavior of wood particles. The approach used in the model development analyzed the rotary drying process in a sequential manner. Beginning with a study of particle residence time in a rotary drum, the process of heat transfer, and then mass transfer, were incorporated to yield a complete rotary dryer simulation model. The resultant computer program does not require empirical constants or equations developed for a particular rotary dryer system. Experiments on a commercially manufactured rotary dryer were performed to check the performance of the simulation model as a predictor of overall residence time and drying behavior. Comparison between the predictions and the measured results were good, indicating a percent root mean square error of 22.2 in the prediction of the outlet particle moisture content. The rotary dryer simulation model developed in this study should prove useful for optimizing process parameters in the drying of wood particles.

  3. Nylon screws make inexpensive coil forms

    Aucoin, G.; Rosenthal, C.


    Standard nylon screws act as coil form copper wire laid down in spiral thread. Completed coil may be bonded to printed-circuit board. However, it is impossible to tune coil by adjusting spacing between windings, technique sometimes used with air-core coils.

  4. Nylon screws make inexpensive coil forms

    Aucoin, G.; Rosenthal, C.


    Standard nylon screws act as coil form copper wire laid down in spiral thread. Completed coil may be bonded to printed-circuit board. However, it is impossible to tune coil by adjusting spacing between windings, technique sometimes used with air-core coils.

  5. A phenomenological study on twin screw extruders

    Janssen, L.P.B.M.


    Although more and more twin screw extruders are being used in the polymer industry, the theoretical background is relatively undeveloped. The literature abounds in contradictions and often informs the reader that all extrusion problems can be solved if a certain new design is considered. The develop

  6. Prevention of thinning at disc center during rotary forging


    Presents the simulation and analysis of the rotary forging of a disc using a finite element method, which re veals the thinning at the disc center is caused by higher radial and tangential tensile stresses resulting from the local loading of a rotary die and acting at the center of a workpiece, and proposes a new design of rotary die with a hole opened in its center to prevent the continuous occurrence of shortening in the axial direction and elongation in the tan gential and radial directions, and concludes from simulation results that the rotary die with a hole opened in its center is effective for prevention of thinning or cracking at the center of a disc during rotary forging.

  7. Expandable pallet for space station interface attachments

    Wesselski, Clarence J. (Inventor)


    A foldable expandable pallet having a basic square configuration is disclosed. Each pallet is comprised of a plurality of struts, joined together by node point fittings to make a rigid structure. Some of the struts have hinge fittings and are spring loaded to permit collapse of the module for stowage and transport to a space station. Dimensions of the pallet are selected to provide convenient, closely spaced attachment points between the relatively widely spaced trusses of a space station platform. A pallet is attached to a truss at four points; one close fitting hole; two oversize holes; and a slot; to allow for thermal expansion/contraction and for manufacturing tolerances. Applications of the pallet include its use in rotary or angular joints; servicing of splints; with gridded plates; as an instrument mounting bases; and as a roadbed for a Mobile Service Center (MSC).

  8. Rotational Efficiency of Photo-Driven Archimedes Screws for Micropumps

    Chih-Lang Lin


    Full Text Available In this study, we characterized the rotational efficiency of the photo-driven Archimedes screw. The micron-sized Archimedes screws were fabricated using the two-photon polymerization technique. Free-floating screws trapped by optical tweezers align in the laser irradiation direction and rotate spontaneously. The influences of the screw pitch and the number of screw blades have been investigated in our previous studies. In this paper, the blade thickness and the central rod of the screw were further investigated. The experimental results indicate that the blade thickness contributes to rotational stability, but not to rotational speed, and that the central rod stabilizes the rotating screw but is not conducive to rotational speed. Finally, the effect of the numerical aperture (NA of the optical tweezers was investigated through a demonstration. The NA is inversely proportional to the rotational speed.

  9. A Review of Screw Conveyors Performance Evaluation During Handling Process

    Hemad Zareiforoush


    Full Text Available This paper reviews recent work on screw conveyors performance evaluation during handling process, especially in the case of agricultural grains and bulk materials. Experimental work has been mainly carried out to determine a range of parameters, such as auger dimension, screw rotational speed, screw clearance, conveyor intake length and conveying angle for horizontal, inclined and vertical screw conveyors. Several measurement techniques including theoretical models and DEM have been utilized to study the screw conveyors performance. However, each of these techniques is limited in its application. Difficulties in representing vortex motion and interactions among conveying grains and between the particles and screw rotating flight have so far limited the success of advanced modeling. Further work is needed to be conducted on screw augers performance to understand and improve the agricultural grains and bulk materials handling process.

  10. Atlantoaxial stabilization using multiaxial C-1 posterior arch screws.

    Donnellan, Michael B; Sergides, Ioannis G; Sears, William R


    The authors present a novel technique of atlantoaxial fixation using multiaxial C-1 posterior arch screws. The technique involves the insertion of bilateral multiaxial C-1 posterior arch screws, which are connected by crosslinked rods to bilateral multiaxial C-2 pars screws. The clinical results are presented in 3 patients in whom anomalies of the vertebral arteries, C-1 lateral masses, and/or posterior arch of C-1 presented difficulty using existing fixation techniques with transarticular screws, C-1 lateral mass screws, or posterior wiring. The C-1 posterior arch screws achieved solid fixation and their insertion appeared to be technically less demanding than that of transarticular or C-1 lateral mass screws. This technique may reduce the risk of complications compared with existing techniques, especially in patients with anatomical variants of the vertebral artery, C-1 lateral masses, or C-1 posterior arch. This technique may prove to be an attractive fixation option in patients with normal anatomy.

  11. Development of a Piezoelectric Rotary Hammer Drill

    Domm, Lukas N.


    The Piezoelectric Rotary Hammer Drill is designed to core through rock using a combination of rotation and high frequency hammering powered by a single piezoelectric actuator. It is designed as a low axial preload, low mass, and low power device for sample acquisition on future missions to extraterrestrial bodies. The purpose of this internship is to develop and test a prototype of the Piezoelectric Rotary Hammer Drill in order to verify the use of a horn with helical or angled cuts as a hammering and torque inducing mechanism. Through an iterative design process using models in ANSYS Finite Element software and a Mason's Equivalent Circuit model in MATLAB, a horn design was chosen for fabrication based on the predicted horn tip motion, electromechanical coupling, and neutral plane location. The design was then machined and a test bed assembled. The completed prototype has proven that a single piezoelectric actuator can be used to produce both rotation and hammering in a drill string through the use of a torque inducing horn. Final data results include bit rotation produced versus input power, and best drilling rate achieved with the prototype.

  12. Fluid Dynamics in Rotary Piston Blood Pumps.

    Wappenschmidt, Johannes; Sonntag, Simon J; Buesen, Martin; Gross-Hardt, Sascha; Kaufmann, Tim; Schmitz-Rode, Thomas; Autschbach, Ruediger; Goetzenich, Andreas


    Mechanical circulatory support can maintain a sufficient blood circulation if the native heart is failing. The first implantable devices were displacement pumps with membranes. They were able to provide a sufficient blood flow, yet, were limited because of size and low durability. Rotary pumps have resolved these technical drawbacks, enabled a growing number of mechanical circulatory support therapy and a safer application. However, clinical complications like gastrointestinal bleeding, aortic insufficiency, thromboembolic complications, and impaired renal function are observed with their application. This is traced back to their working principle with attenuated or non-pulsatile flow and high shear stress. Rotary piston pumps potentially merge the benefits of available pump types and seem to avoid their complications. However, a profound assessment and their development requires the knowledge of the flow characteristics. This study aimed at their investigation. A functional model was manufactured and investigated with particle image velocimetry. Furthermore, a fluid-structure interaction computational simulation was established to extend the laboratory capabilities. The numerical results precisely converged with the laboratory measurements. Thus, the in silico model enabled the investigation of relevant areas like gap flows that were hardly feasible with laboratory means. Moreover, an economic method for the investigation of design variations was established.

  13. A metering rotary nanopump for microfluidic systems.

    Darby, Scott G; Moore, Matthew R; Friedlander, Troy A; Schaffer, David K; Reiserer, Ron S; Wikswo, John P; Seale, Kevin T


    We describe the design, fabrication, and testing of a microfabricated metering rotary nanopump for the purpose of driving fluid flow in microfluidic devices. The miniature peristaltic pump is composed of a set of microfluidic channels wrapped in a helix around a central camshaft in which a non-cylindrical cam rotates. The cam compresses the helical channels to induce peristaltic flow as it is rotated. The polydimethylsiloxane (PDMS) nanopump design is able to produce intermittent delivery or removal of several nanolitres of fluid per revolution as well as consistent continuous flow rates ranging from as low as 15 nL min(-1) to above 1.0 µL min(-1). At back pressures encountered in typical microfluidic devices, the pump acts as a high impedance flow source. The durability, biocompatibility, ease of integration with soft-lithographic fabrication, the use of a simple rotary motor instead of multiple synchronized pneumatic or mechanical actuators, and the absence of power consumption or fluidic conductance in the resting state all contribute to a compact pump with a low cost of fabrication and versatile implementation. This suggests that the pump design may be useful for a wide variety of biological experiments and point of care devices.

  14. Dynamic Analysis of Foundation Supporting Rotary Machine

    Utkarsh S. Patel


    Full Text Available With the advancement of technology in the field of industry, high speed machinery has been developed. As the speed of machinery has increased, vibrations also increased. Machines transmit vibrations to the structure supporting them. Hence, it is important to design and develop such structure which sustains the vibrations of machinery. Hence, in this study it has been aimed to execute the study on foundations supporting rotary type of machine like blower. In this paper, the most important parameters like frequency and amplitude are considered while execution of analysis of machine foundation supporting blower type machine. This paper shows, better interface between foundation designer and machine manufacturer for better performance of machine. The design aids/approaches for foundation design is also described in this paper and an attempt has been made to study the dynamic behaviour of a foundation structure for blower type machine subjected to forces due to operation of blower machine. Two different types of foundations for Rotary type Machine that is Blower have been studied in this paper

  15. Development of natural gas rotary engines

    Mack, J. R.


    Development of natural gas-fueled rotary engines was pursued on the parallel paths of converted Mazda automotive engines and of establishing technology and demonstration of a test model of a larger John Deer Technologies Incorporated (JDTI) rotary engine with power capability of 250 HP per power section for future production of multi-rotor engines with power ratings 250, 500, and 1000 HP and upward. Mazda engines were converted to natural gas and were characterized by a laboratory which was followed by nearly 12,000 hours of testing in three different field installations. To develop technology for the larger JDTI engine, laboratory and engine materials testing was accomplished. Extensive combustion analysis computer codes were modified, verified, and utilized to predict engine performance, to guide parameters for actual engine design, and to identify further improvements. A single rotor test engine of 5.8 liter displacement was designed for natural gas operation based on the JDTI 580 engine series. This engine was built and tested. It ran well and essentially achieved predicted performance. Lean combustion and low NOW emission were demonstrated.

  16. Research and application of absorbable screw in orthopedics: a clinical review comparing PDLLA screw with metal screw in patients with simple medial malleolus fracture

    TANG Jin


    Full Text Available 【Abstract】Objective: To observe the therapeutic effect of absorbable screw in medial malleolus fracture and discuss its clinical application in orthopedics. Methods: A total of 129 patients with simple medial malleolus fracture were studied. Among them, 64 patients were treated with poly-D, L-lactic acid (PDLLA absorbable screws, while the others were treated with metal screws. All the patients were followed up for 12-20 months (averaged 18.4 months and the therapeutic effect was evaluated ac-cording to the American Orthopaedic Foot and Ankle Soci-ety clinical rating systems. Results: In absorbable screw group, we obtained excel-lent and good results in 62 cases (96.88%; in steel screw group, 61 cases (93.85% achieved excellent and good results. There was no significant difference between the two groups. Conclusion: In the treatment of malleolus fracture, absorbable screw can achieve the same result compared with metal screw fixation. Absorbable screw is preferred due to its advantages of safety, cleanliness and avoiding the removal procedure associated with metallic implants. Key words: Ankle; Bone screws; Fractures, bone

  17. Biomechanical comparison of cervical fixation via transarticular facet screws without rods versus lateral mass screws with rods.

    Yi, Seong; Rim, Dae-Cheol; Nam, Ki-Se; Keem, Sang-Hyun; Murovic, Judith A; Lim, Jesse; Park, Jon


    Transarticular facet screws restore biomechanical stability to the cervical spine when posterior cervical anatomy has been compromised. This study compares the more recent, less invasive, and briefer transarticular facet screw system without rods with the lateral mass screw system with rods. For this study, 6 human cervical spines were obtained from cadavers. Transarticular facet screws without rods were inserted bilaterally into the inferior articular facets at the C5-C6 and C5-C6-C7 levels. Lateral mass screws with rods were inserted bilaterally at the same levels using Magerl's technique. All specimens underwent range of motion (ROM) testing by a material testing machine for flexion, extension, lateral bending, and axial rotation. Both fixation methods, transarticular facet screws without rods and lateral mass screws with rods, reduced all ROM measurements and increased spinal stiffness. No statistically significant differences between the 2 stabilization methods were found in ROM measurements for 1-level insertions. However, in 2-level insertions, ROM for the nonrod transarticular facet screw group was significantly increased for flexion-extension and lateral bending. Transarticular facet screws without rods and lateral mass screws with rods had similar biomechanical stability in single-level insertions. For 2-level insertions, transarticular facet screws without rods are a valid option in cervical spine repair. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Biomechanical performance of subpectoral biceps tenodesis: a comparison of interference screw fixation, cortical button fixation, and interference screw diameter.

    Sethi, Paul M; Rajaram, Arun; Beitzel, Knut; Hackett, Thomas R; Chowaniec, David M; Mazzocca, Augustus D


    Subpectoral biceps tenodesis with interference screw fixation allows reproducible positioning of the tendon to help maintain the length-tension relationship. The aim of our study was to evaluate the role of cortical button fixation in isolation or as an augment to interference screw fixation and to determine if the diameter of the interference screw affected fixation strength. Thirty-two cadaveric shoulders were dissected and randomized to 1 of 4 groups: (1) 7-mm interference screw and cortical button, (2) cortical button alone, (3) 7-mm interference screw, or (4) 8-mm interference screw. Testing was performed on a materials testing system with a 100-N load cycled at 1 Hz for 5000 cycles, followed by an axial load to failure test. Cyclic displacement, ultimate load to failure, and site of failure were recorded for each specimen. The mean ultimate failure loads were 7-mm interference screw with cortical button augmentation, 237.8 ± 120.4 N; cortical button alone, 99.4 ± 16.9 N; 7-mm interference screw, 275.5 ± 56 N; 8-mm interference screw, 277.1 ± 42.1 N. All specimens failed through tendon failure at the screw-tendon-bone interface. The biomechanical performance of subpectoral biceps tenodesis with interference screw fixation was not improved with cortical button augmentation. In addition, cortical button fixation alone yielded a significantly lower ultimate load to failure compared with interference screws. Finally, the biomechanical performance of smaller-diameter interference screws with matching bone tunnels was not affected by interference screw diameter. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  19. Highly precise and compact ultrahigh vacuum rotary feedthrough

    Aiura, Y.; Kitano, K.


    The precision and rigidity of compact ultrahigh vacuum (UHV) rotary feedthroughs were substantially improved by preparing and installing an optimal crossed roller bearing with mounting holes. Since there are mounting holes on both the outer and inner races, the bearing can be mounted directly to rotary and stationary stages without any fixing plates and housing. As a result, it is possible to increase the thickness of the bearing or the size of the rolling elements in the bearing without increasing the distance between the rotating and fixing International Conflat flanges of the UHV rotary feedthrough. Larger rolling elements enhance the rigidity of the UHV rotary feedthrough. Moreover, owing to the structure having integrated inner and outer races and mounting holes, the performance is almost entirely unaffected by the installation of the bearing, allowing for a precise optical encoder to be installed in the compact UHV rotary feedthrough. Using position feedback via a worm gear system driven by a stepper motor and a precise rotary encoder, the actual angle of the compact UHV rotary feedthrough can be controlled with extremely high precision.

  20. Correlation Development for Sauter Mean Diameter of Rotary Atomizer



    Full Text Available Atomizers are of many types, among that simplex and duplex types of atomizers are used and recognized often as fuel injectors in aircrafts. Types of atomizers and features are read. Among many types of atomizer, rotary type of atomizer is selected due to its naked evident like easy retrofit to existing spreading system , able to handle large quantities, feed is possible, better economy, high peripheral speed and spread of droplets, uniform liquid feed rate, uniform distribution of feed, higher level of atomization etc., The rotary atomizer specifications and its features are listed, the droplets of rotary atomizer are visualized and readings are taken from experimental methods, such as Laser visualization method .After the droplets data alignment, the (SMD Sauter Mean Diameter is to be taken in and considered, SMD means it is a average particle (droplet size of a given particles, and it is further explained with its given relation. By SMD’s given equated form it is used to compare data between rotary atomizer particles and given particle size. By SMD it is simplified further and used to create a co-relation between SMD and rotary atomizer. The rotary atomizer data values are taken through out with the SMD to find and form a co-related derived pattern for ROTARY ATOMIZE

  1. Strategy for salvage pedicle screw placement: A technical note.

    Fujibayashi, Shunsuke; Takemoto, Mitsuru; Neo, Masashi; Matsuda, Shuichi


    Salvage surgery for failed lumbar spine fusion with a loosened pedicle screw is challenging. In general, the strategy includes replacement with larger and longer pedicle screws, augmentation with polymethylmethacrylate cement or hydroxyapatite granules, and extension of fused segments. The purpose of this study is to introduce a new technique for pedicle screw replacement after failed lumbar spine fusion. Five salvage operations were performed using a different trajectory (DT) pedicle screw replacement technique based on 3-dimensional radiological information. Position of the alternative pedicle screws was planned carefully on the computer screen of a computed tomography-based navigation system before the operation. To obtain sufficient initial stability, 1 of 2 techniques was chosen, depending on the patient. One technique created a completely new route, which did not interfere with the existing screw hole, and the other involved penetration of the existing screw hole. DT pedicle screws were replaced successfully according to the preoperative plan. In all patients, bony union were achieved at the final follow-up period without any instrument failure. Extension of the fused segments could be avoided by using the DT pedicle screw replacement technique combined with transforaminal lumbar interbody fusion. The DT pedicle screw replacement technique is a treatment option for salvage lumbar spine surgery. The current technique is a treatment option for salvage operations that can both avoid extension of a fused segment and achieve successful bony union.

  2. The applicability of PEEK-based abutment screws.

    Schwitalla, Andreas Dominik; Abou-Emara, Mohamed; Zimmermann, Tycho; Spintig, Tobias; Beuer, Florian; Lackmann, Justus; Müller, Wolf-Dieter


    The high-performance polymer PEEK (poly-ether-ether-ketone) is more and more being used in the field of dentistry, mainly for removable and fixed prostheses. In cases of screw-retained implant-supported reconstructions of PEEK, an abutment screw made of PEEK might be advantageous over a conventional metal screw due to its similar elasticity. Also in case of abutment screw fracture, a screw of PEEK could be removed more easily. M1.6-abutment screws of four different PEEK compounds were subjected to tensile tests to set their maximum tensile strengths in relation to an equivalent stress of 186MPa, which is aused by a tightening torque of 15Ncm. Two screw types were manufactured via injection molding and contained 15% short carbon fibers (sCF-15) and 40% (sCF-40), respectively. Two screw types were manufactured via milling and contained 20% TiO2 powder (TiO2-20) and >50% parallel orientated, continuous carbon fibers (cCF-50). A conventional abutments screw of Ti6Al4V (Ti; CAMLOG(®) abutment screw, CAMLOG, Wimsheim, Germany) served as control. The maximum tensile strength was 76.08±5.50MPa for TiO2-20, 152.67±15.83MPa for sCF-15, 157.29±20.11MPa for sCF-40 and 191.69±36.33MPa for cCF-50. The maximum tensile strength of the Ti-screws amounted 1196.29±21.4MPa. The results of the TiO2-20 and the Ti screws were significantly different from the results of the other samples, respectively. For the manufacturing of PEEK abutment screws, PEEK reinforced by >50% continuous carbon fibers would be the material of choice. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Measurement and evaluation of static characteristics of rotary hydraulic motor

    Hružík Lumír


    Full Text Available The paper describes experimental equipment for measurement of static characteristics of rotary hydraulic motor. It is possible to measure flow, pressure, temperature, speed and torque by means of this equipment. It deals with measurement of static characteristics of a gear rotary hydraulic motor. Mineral oil is used as hydraulic liquid in this case. Flow, torque and speed characteristics are evaluated from measured parameters. Measured mechanical-hydraulic, flow and total efficiencies of the rotary hydraulic motor are adduced in the paper. It is possible to diagnose technical conditions of the hydraulic motor (eventually to recommend its exchange from the experimental measurements.

  4. Numerical Evaluation of Brick Lining Status in Rotary Kilns


    Rotary kilns are important in a variety of different manufacturing areas for e.g. calcination and sintering of materials. In fact, two of the most produced materials in the world, cement and iron, are likely to start their journey in a rotary kiln.A rotary kiln is a large cylinder-formed furnace which rotates about its axis and where certain chemical and physical reactions take place by the influence of heat. The slope and the rotation make the material inside to move through the kiln from fe...

  5. Impact of screw elements on continuous granulation with a twin-screw extruder.

    Djuric, Dejan; Kleinebudde, Peter


    The influence of different screw element types on wet granulation process with a twin-screw extruder was investigated. Lactose granules were prepared with different screw configurations such as conveying, combing mixer and kneading elements. The use of kneading blocks led to an almost complete agglomeration of lactose, whereas kneading and combing mixer elements resulted in smaller granules in comparison. Granule porosity varied between 17.4% and 50.6%. Granule friability values ranged from 1.2% to 38.5%. Conveying elements led to the most porous and friable granules, whereas kneading blocks produced the densest and least friable granules. Combing mixer elements produced granules with median properties. A linear correlation between granule porosity and the natural logarithm of granule friability was detected. Flowability of granules was also influenced by the element type. Compressed granules with higher granule porosities resulted in tablets with higher tensile strength values and vice versa. Twin-screw extruders proved to be a versatile tool for wet granulation. By the choice of a suitable screw element granule and tablet characteristics were influenced.

  6. Torque for an Inertial Piezoelectric Rotary Motor

    Jichun Xing


    Full Text Available For a novel inertial piezoelectric rotary motor, the equation of the strain energy in the piezoceramic bimorph and the equations of the strain energy and the kinetic energy in the rotor are given. Based on them, the dynamic equation of the motor is obtained. Using these equations, the inertial driving torque of the motor is investigated. The results show that the impulsive driving torque changes with changing peak voltage of the excitation signal, the piezoelectric stress constant, the thickness of the piezoceramic bimorph, and the rotor radius obviously. Tests about the motor torque are completed which verifies the theory analysis here in. The results can be used to design the operating performance of the motor.

  7. Rotary fast tool servo system and methods

    Montesanti, Richard C.; Trumper, David L.


    A high bandwidth rotary fast tool servo provides tool motion in a direction nominally parallel to the surface-normal of a workpiece at the point of contact between the cutting tool and workpiece. Three or more flexure blades having all ends fixed are used to form an axis of rotation for a swing arm that carries a cutting tool at a set radius from the axis of rotation. An actuator rotates a swing arm assembly such that a cutting tool is moved in and away from the lathe-mounted, rotating workpiece in a rapid and controlled manner in order to machine the workpiece. A pair of position sensors provides rotation and position information for a swing arm to a control system. A control system commands and coordinates motion of the fast tool servo with the motion of a spindle, rotating table, cross-feed slide, and in-feed slide of a precision lathe.

  8. Film riding seals for rotary machines

    Bidkar, Rahul Anil; Sarawate, Neelesh Nandkumar; Wolfe, Christopher Edward; Ruggiero, Eric John; Raj Mohan, Vivek Raja


    A seal assembly for a rotary machine is provided. The seal assembly includes multiple sealing device segments disposed circumferentially intermediate to a stationary housing and a rotor. Each of the segments includes a shoe plate with a forward-shoe section and an aft-shoe section having one or more labyrinth teeth therebetween facing the rotor. The sealing device includes a stator interface element having a groove or slot for allowing disposal of a spline seal for preventing segment leakages. The sealing device segment also includes multiple bellow springs or flexures connected to the shoe plate and to the stator interface element. Further, the sealing device segments include a secondary seal integrated with the stator interface element at one end and positioned about the multiple bellow springs or flexures and the shoe plate at the other end.

  9. Rotary seal with improved film distribution

    Dietle, Lannie Laroy; Schroeder, John Erick


    The present invention is a generally circular rotary seal that establishes sealing between relatively rotatable machine components for lubricant retention and environmental exclusion, and incorporates seal geometry that interacts with the lubricant during relative rotation to distribute a lubricant film within the dynamic sealing interface. The features of a variable inlet size, a variable dynamic lip flank slope, and a reduction in the magnitude and circumferentially oriented portion of the lubricant side interfacial contact pressure zone at the narrowest part of the lip, individually or in combination thereof, serve to maximize interfacial lubrication in severe operating conditions, and also serve to minimize lubricant shear area, seal torque, seal volume, and wear, while ensuring retrofitability into the seal grooves of existing equipment.

  10. Rotary seal with improved film distribution

    Dietle, Lannie Laroy; Schroeder, John Erick


    The present invention is a generally circular rotary seal that establishes sealing between relatively rotatable machine components for lubricant retention and environmental exclusion, and incorporates seal geometry that interacts with the lubricant during relative rotation to distribute a lubricant film within the dynamic sealing interface. The features of a variable inlet size, a variable dynamic lip flank slope, and a reduction in the magnitude and circumferentially oriented portion of the lubricant side interfacial contact pressure zone at the narrowest part of the lip, individually or in combination thereof, serve to maximize interfacial lubrication in severe operating conditions, and also serve to minimize lubricant shear area, seal torque, seal volume, and wear, while ensuring retrofitability into the seal grooves of existing equipment.

  11. Analysis of Modeling Parameters on Threaded Screws.

    Vigil, Miquela S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brake, Matthew Robert [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Vangoethem, Douglas [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)


    Assembled mechanical systems often contain a large number of bolted connections. These bolted connections (joints) are integral aspects of the load path for structural dynamics, and, consequently, are paramount for calculating a structure's stiffness and energy dissipation prop- erties. However, analysts have not found the optimal method to model appropriately these bolted joints. The complexity of the screw geometry cause issues when generating a mesh of the model. This paper will explore different approaches to model a screw-substrate connec- tion. Model parameters such as mesh continuity, node alignment, wedge angles, and thread to body element size ratios are examined. The results of this study will give analysts a better understanding of the influences of these parameters and will aide in finding the optimal method to model bolted connections.

  12. Translaminar facetal screw (magerl′s fixation

    Rajasekaran S


    Full Text Available Translaminar facet screw fixation (TLFS achieves stabilization of the vertebral motion segment by screws inserted at the base of the spinous process, through the opposite lamina, traversing the facet joint, and ending in the base of the transverse process. It is simple, does not require any specialized equipment, and has the advantages of being a procedure of lesser magnitude, lesser operative time, less cost and few complication rate. Recently there is growing interest in this technique to augment the anterior lumbar fusions to achieve global fusion less invasively. In this review article, we discuss the clinical and biomechanical considerations, surgical technique, indications, contraindications and recent developments of TLFS fixation in lumbar spine fusion.

  13. Twin screw granulation - review of current progress.

    Thompson, M R


    Twin screw granulation (TSG) is a new process of interest to the pharmaceutical community that can continuously wet granulate powders, doing so at lower liquid concentrations and with better product consistency than found by a high shear batch mixer. A considerable body of research has evolved over the short time since this process was introduced but generally with little comparison of results. A certain degree of confidence has been developed through these studies related to how process variables and many attributes of machinery configuration will affect granulation but some major challenges still lay ahead related to scalability, variations in the processing regimes related to degree of channel fill and the impact of wetting and granulation of complex powder formulations. This review examines the current literature for wet granulation processes studied in twin screw extrusion machinery, summarizing the influences of operational and system parameters affecting granule properties as well as strives to provide some practical observations to newly interested users of the technique.


    ZHOU Wang-min; SONG Yu-hai


    The elasticity theory of the dislocation of cubic quasicrystals is developed.The governing equations of anti-plane elasticity dynamics problem of the quasicrystals were reduced to a solution of wave equations by introducing displacement functions,and the analytical expressions of displacements, stresses and energies induced by a moving screw dislocation in the cubic quasicrystalline and the velocity limit of the dislocation were obtained. These provide important information for studying the plastic deformation of the new solid material.

  15. In vitro evaluation of force-expansion characteristics in a newly designed orthodontic expansion screw compared to conventional screws

    Oshagh Morteza


    Full Text Available Objective : Expansion screws like Hyrax, Haas and other types, produce heavy interrupted forces which are unfavorable for dental movement and could be harmful to the tooth and periodontium. The other disadvantage of these screws is the need for patient cooperation for their regular activation. The purpose of this study was to design a screw and compare its force- expansion curve with other types. Materials and Methods : A new screw was designed and fabricated in the same dimension, with conventional types, with the ability of 8 mm expansion (Free wire length: 12 mm, initial compression: 4.5 mm, spring wire diameter: 0.4 mm, spring diameter: 3 mm, number of the coils: n0 ine, material: s0 tainless steel. In this in vitro study, the new screw was placed in an acrylic orthodontic appliance, and after mounting on a stone cast, the force-expansion curve was evaluated by a compression test machine and compared to other screws. Results : Force-expansion curve of designed screw had a flatter inclination compared to other screws. Generally it produced a light continuous force (two to 3.5 pounds for every 4 mm of expansion. Conclusion : In comparison with heavy and interrupted forces of other screws, the newly designed screw created light and continuous forces.

  16. Biomechanical comparison of interference screw and cortical button with screw hybrid technique for distal biceps brachii tendon repair.

    Arianjam, Afshin; Camisa, William; Leasure, Jeremi M; Montgomery, William H


    Various fixation techniques have been described for ruptured distal biceps tendons. The authors hypothesized that no significant differences would be found between the mean failure strength, maximum strength, and stiffness of the interference screw and hybrid technique. Fourteen fresh-frozen human cadaveric elbows were prepared. Specimens were randomized to either interference screw or hybrid cortical button with screw fixation. The tendon was pulled at a rate of 4 mm/s until failure. Failure strength, maximum strength, and stiffness were measured and compared. Failure strength, maximum strength, and stiffness were 294±81.9 N, 294±82.1 N, and 64.4±40.5 N/mm, respectively, for the interference screw technique and 333±129 N, 383±121 N, and 56.2±40.5 N/mm, respectively, for the hybrid technique. No statistically significant difference existed between the screw and hybrid technique in failure strength, maximum strength, or stiffness (P>.05). The interference screws primarily failed by pullout of the screw and tendon, whereas in the hybrid technique, failure occurred with screw pullout followed by tearing of the biceps tendon. The results suggest that this hybrid technique is nearly as strong and stiff as the interference screw alone. Although the hybrid technique facilitates tensioning of the reconstructed tendon, the addition of the cortical button did not significantly improve the failure strength of the interference screw alone. Copyright 2013, SLACK Incorporated.

  17. Research and application of absorbable screw in orthopedics: a clinical review comparing PDLLA screw with metal screw in patients with simple medial malleolus fracture

    TANG Jin; HU Jin-feng; GUO Wei-chun; YU Ling; ZHAO Sheng-hao


    Objective:To observe the therapeutic effect of absorbable screw in medial malleolus fracture and discuss its clinical application in orthopedics.Methods:A total of 129 patients with simple medial malleolus fracture were studied.Among them,64 patients were treated with poly-D,L-lactic acid (PDLLA) absorbable screws,while the others were treated with metal screws.All the patients were followed up for 12-20 months (averaged 18.4 months) and the therapeutic effect was evaluated according to the American Orthopaedic Foot and Ankle Society clinical rating systems.Results:In absorbable screw group,we obtained excellent and good results in 62 cases (96.88%); in steel screw group,61 cases (93.85%) achieved excellent and good results.There was no significant difference between the two groups.Conclusion:In the treatment of malleolus fracture,absorbable screw can achieve the same result compared with metal screw fixation.Absorbable screw is preferred due to its advantages of safety,cleanliness and avoiding the removal procedure associated with metallic implants.

  18. Biopolymer augmentation of the lag screw in the treatment of femoral neck fractures - a biomechanical in-vitro study

    Paech A


    Full Text Available Abstract The cut-out of the sliding screw is one of the most common complications in the treatment of intertrochanteric fractures. The reasons for the cut-out are: a suboptimal position of the hip-screw in the femoral head, the type of fracture and poor bone quality. The aim of this study was to reproduce the cut-out event biomechanically and to evaluate the possible prevention of this event by the use of a biopolymer augmentation of the hip screw. Concerning the density and compression force of osteoporotic femoral bone polyurethane foam according to the terms of the Association for Standard Testing Material (ASTMF 1839-97 was used as test material. The polyurethane foam Lumoltan 200 with a compression force of 3.3 Mpa and a density of 0.192 g/cm3 was used to reproduce the osteoporotic bone of the femoral fragment (density 12 lbm/ft3. A cylinder of 50 mm of length and 50 mm of width was produced by a rotary splint raising procedure with planar contact. The axial load of the system was performed by a hydraulic force cylinder of a universal test machine type Zwick 1455, Ulm, Germany. The CCD-angle of the used TGN-System was preset at 130 degrees. The migration pattern of the hip screw in the polyurethane foam was measured and expressed as a curve of the distance in millimeter [mm] against the applied load in Newton [N] up to the cut-out point. During the tests the implants reached a critical changing point from stable to unstable with an increased load progression of steps of 50 Newton. This unstable point was characterized by an increased migration speed in millimeters and higher descending gradient in the migration curve. This peak of the migration curve served as an indicator for the change of the hip screw position in the simulated bone material. The applied load in the non-augmented implant showed that in this group for a density degree of 12 (0,192 g/cm3 the mean force at the failure point was 1431 Newton (± 52 Newton. In the augmented

  19. Rotary klubi tuli rannarahvale appi / Anu Jürisson

    Jürisson, Anu


    Tallinna Vanalinna Rotary klubi kinkis kolmele Rannametsa perele kümme tuhat krooni jaanuaritormi kahjustuste likvideerimiseks. Klubi presidendiks on Allan Martinson, nimekirjas ka Tõnis Palts, Toomas Hendrik Ilves, Rein Kilk, Hans H. Luik, Vahur Kraft jt.

  20. Dose Rate Calculations for Rotary Mode Core Sampling Exhauster

    Foust, D J


    This document provides the calculated estimated dose rates for three external locations on the Rotary Mode Core Sampling (RMCS) exhauster HEPA filter housing, per the request of Characterization Field Engineering.

  1. Rotation of artificial rotor axles in rotary molecular motors

    Baba, Mihori; Iwamoto, Kousuke; Iino, Ryota; Ueno, Hiroshi; Hara, Mayu; Nakanishi, Atsuko; Kishikawa, Jun-ichi; Noji, Hiroyuki; Yokoyama, Ken


    [F.sub.1]- and [V.sub.1]-ATPase are rotary molecular motors that convert chemical energy released upon ATP hydrolysis into torque to rotate a central rotor axle against the surrounding catalytic stator cylinder with high efficiency...

  2. Research on rotary forming mechanism of cartridge bottom by FEM

    刘钢; 姚雄亮; 黄少东; 唐全波


    The rotary forging of a cartridge bottom is simulated by finite element method with DEFORMTM. The analysis of stress and strain rate results indicates that the deformation conditions and the final geometry of a product are not completely axis-symmetrical under the partial loading conditions during the rotary forging operations. It is therefore required to have a few more rotary forging cycles at the end of total feeding to eliminate nonuniformity. The results of simulation show that the optimization of rotary forging process conditions can be achieved to avoid the underfill defect resulting from improper process conditions. This technology can be used to manufacture ring components with thin bottoms by properly controlling the working process and the tooling motion.

  3. Rotary endodontics in primary teeth – A review

    Sageena George


    Full Text Available Endodontic treatment in primary teeth can be challenging and time consuming, especially during canal preparation, which is considered one of the most important steps in root canal therapy. The conventional instrumentation technique for primary teeth remains the “gold-standard” over hand instrumentation, which makes procedures much more time consuming and adversely affects both clinicians and patients. Recently nickel–titanium (Ni–Ti rotary files have been developed for use in pediatric endodontics. Using rotary instruments for primary tooth pulpectomies is cost effective and results in fills that are consistently uniform and predictable. This article reviews the use of nickel–titanium rotary files as root canal instrumentation in primary teeth. The pulpectomy technique is described here according to different authors and the advantages and disadvantages of using rotary files are discussed.

  4. Rotary klubi tuli rannarahvale appi / Anu Jürisson

    Jürisson, Anu


    Tallinna Vanalinna Rotary klubi kinkis kolmele Rannametsa perele kümme tuhat krooni jaanuaritormi kahjustuste likvideerimiseks. Klubi presidendiks on Allan Martinson, nimekirjas ka Tõnis Palts, Toomas Hendrik Ilves, Rein Kilk, Hans H. Luik, Vahur Kraft jt.

  5. Discrete element modelling of screw conveyor-mixers

    Jovanović Aca


    Full Text Available Screw conveyors are used extensively in food, plastics, mineral processing, agriculture and processing industries for elevating and/or transporting bulk materials over short to medium distances. Despite their apparent simplicity in design, the transportation action is very complex for design and constructors have tended to rely heavily on empirical performance data. Screw conveyor performance is affected by its operating conditions (such as: the rotational speed of the screw, the inclination of the screw conveyor, and its volumetric fill level. In this paper, horizontal, several single-pitch screw conveyors with some geometry variations in screw blade was investigated for mixing action during transport, using Discrete Element Method (DEM. The influence of geometry modifications on the performance of screw conveyor was examined, different screw designs were compared, and the effects of geometrical variations on mixing performances during transport were explored. During the transport, the particle tumbles down from the top of the helix to the next free surface and that segment of the path was used for auxiliary mixing action. The particle path is dramatically increased with the addition of three complementary helices oriented in the same direction as screw blades (1458.2 mm compared to 397.6 mm in case of single flight screw conveyor Transport route enlarges to 1764.4 mm, when installing helices oriented in the opposite direction from screw blades. By addition of straight line blade to single flight screw conveyor, the longest particle path is being reached: 2061.6 mm [Projekat Ministarstva nauke Republike Srbije, br. TR-31055

  6. Economics of water injected air screw compressor systems

    Madhav, K. V.; Kovacevic, A.


    There is a growing need for compressed air free of entrained oil to be used in industry. In many cases it can be supplied by oil flooded screw compressors with multi stage filtration systems, or by oil free screw compressors. However, if water injected screw compressors can be made to operate reliably, they could be more efficient and therefore cheaper to operate. Unfortunately, to date, such machines have proved to be insufficiently reliable and not cost effective. This paper describes an in...

  7. Finite Element Analysis of Reciprocating Screw for Injection Molding Machine

    Nagsen B. Nagrale


    Full Text Available This paper deals with, the solution of problem occurred for reciprocating screw of Injection molding machine. It identifies and solves the problem by using the modeling and simulation techniques. The problem occurred in the reciprocating screw of machine which was wearing of threads due to affect of temperature of mold materials(flow materials i.e. Nylon, low density polypropylene, polystyrene, PVC etc., The main work was to model the components of machine with dimensions, assemble those components and then simulate the whole assembly for rotation of the screw. The modeling software used is PRO-E wildfire 4.0 for modeling the machine components like body, movable platen, fixed platen, barrel, screw, nozzle, etc. The analysis software ANSYS is used to analyze the reciprocating screws. The objectives involved are:- • To model all the components using modeling software Pro-E 4.0 • To assemble all the components of the machine in the software. • To make the assembly run in Pro-E software.• Analysis of screw of machine using Ansys 11.0 software. • To identify the wearing of threads and to provide the possible solutions.This problem is major for all industrial injection molding machines which the industries are facing and they need the permanent solution, so if the better solution is achieved then the industries will think for implementing it. The industries are having temporary solution but it will affect the life of the screw, because the stresses will be more in machined screw on lathe machine as compared to normal screw. Also if the screw will fail after some years of operation, the new screw available in the market will have the same problem. Also the cost associated with new screw and its mounting is much more as it is the main component of machine.

  8. Double insurance transfacetal screws for lumbar spinal stabilization

    Atul Goel


    Full Text Available Aim: The authors report experience with 14 cases where two screws or ′′double insurance′′ screws were used for transfacetal fixation of each joint for stabilization of the lumbar spinal segment. The anatomical subtleties of the technique of insertion of screws are elaborated. Materials and Methods: During the period March 2011 to June 2014, 14 patients having lumbar spinal segmental instability related to lumbar canal stenosis were treated by insertion of two screws into each articular assembly by transfacetal technique. After a wide surgical exposure, the articular cartilage was denuded and bone chips were impacted into the joint cavity. For screw insertion in an appropriate angulation, the spinous process was sectioned at its base. The screws (2.8 mm in diameter and 18 mm in length were inserted into the substance of the medial or inferior articular facet of the rostral vertebra via the lateral limit of the lamina approximately 6-8 mm away from the edge of the articular cavity. The screws were inserted 3 mm below the superior edge and 5 mm above the inferior edge of the medial (inferior facets and directed laterally and traversed through the articular cavity into the lateral (superior articular facet of the caudal vertebra toward and into the region of junction of base of transverse process and of the pedicle. During the period of follow-up all treated spinal levels showed firm bone fusion. There was no complication related to insertion of the screws. There was no incidence of screw misplacement, displacementor implant rejection. Conclusions: Screw insertion into the firm and largely cortical bones of facets of lumbar spine can provide robust fixation and firm stabilization of the spinal segment. The large size of the facets provides an opportunity to insert two screws at each spinal segment. The firm and cortical bone material and absence on any neural or vascular structure in the course of the screw traverse provides strength and

  9. What Expands in an Expanding Universe?

    Pacheco, José A De Freitas


    In the present investigation, the possible effects of the expansion of the Universe on systems bonded either by gravitational or electromagnetic forces, are reconsidered. It will be shown that the acceleration (positive or negative) of the expanding background, is the determinant factor affecting planetary orbits and atomic sizes. In the presently accepted cosmology (ΛCDM) all bonded systems are expanding at a decreasing rate that tends to be zero as the universe enters in a de Sitter phase. It is worth mentioning that the estimated expansion rates are rather small and they can be neglected for all practical purposes.

  10. What Expands in an Expanding Universe?



    Full Text Available ABSTRACT In the present investigation, the possible effects of the expansion of the Universe on systems bonded either by gravitational or electromagnetic forces, are reconsidered. It will be shown that the acceleration (positive or negative of the expanding background, is the determinant factor affecting planetary orbits and atomic sizes. In the presently accepted cosmology (ΛCDM all bonded systems are expanding at a decreasing rate that tends to be zero as the universe enters in a de Sitter phase. It is worth mentioning that the estimated expansion rates are rather small and they can be neglected for all practical purposes.

  11. Simulation investigation of flow field inside the rotary engine : during intake and compression stroke

    Poojitganont, T.; Berg, H.P.; Izweik, H.T. [Brandenburg Univ. of Technology Cottbus, Cottbus (Germany)


    As a result of continuously increasing oil prices, automotive industries are looking for alternative power sources for their automobiles. An excellent solution is the hybrid system. However due to the additional weight of its batteries, this causes the total weight of the car to increase. This higher battery weight can be compensated by reducing the weight of the engine. A rotary engine, such as the Wankel rotary engine, has a more attractive power to weight ratio than the normal reciprocating engine. The rotary engine can be treated and evaluated with respect to performance characteristics as a displacement type, four-stroke internal combustion engine, one-cycle similar to the reciprocating engine. For any combustion engine to reach the maximum power output, the mixture formation inside the engine should be considered. The flow phenomenon inside the engine is a key parameter which involves the mixture formation mechanism. This paper investigated the spray characteristic from the injector and the flow phenomena inside the combustion chamber. Its behaviours were studied using computational fluid dynamics simulation. The simulation setup was described in detail, with reference to meshes; initial condition; and boundary condition. Verification of the calculation was also presented. A comparison of the temperature during compression stroke from the analytical calculation and the adiabetic system simulation were also illustrated. Simulation results showed that the speed of the engine provides a proportional effect on the magnitude of air velocity inside the engine, whereas the circulation region can be expanded by increasing the intake pressure during the intake stroke. 9 refs., 1 tab., 13 figs.


    Herman, D.; Fowley, M.; Stefanko, D.


    The Savannah River National Laboratory (SRNL) installed and tested two hydraulically connected SpinTek rotary microfilter (RMF) units to determine the behavior of a multiple filter system. Both units were successfully controlled by a control scheme written in DELTA-V architecture by Savannah River Remediation (SRR) Process Control Engineering personnel. The control system was tuned to provide satisfactory response to changing conditions during the operation of the multi-filter system. Stability was maintained through the startup and shutdown of one of the filter units while the second was still in operation. The installation configuration originally proposed by the Small Colum Ion Exchange (SCIX) project of independent filter and motor mountings may be susceptible to vibration. Significant stiffening of the filter and motor mounts was required to minimize the vibration. Alignment of the motor to the filter was a challenge in this test configuration. The deployment configuration must be easy to manipulate and allow for fine adjustment. An analysis of the vibration signature of the test system identified critical speeds. Whether it corresponds to the resonance frequency of a rotor radial vibration mode that was excited by rotor unbalance is uncertain based upon the measurements. A relative motion series should be completed on the filter with the final shaft configuration to determine if the resonances exist in the final filter design. The instrumentation selected for deployment, including the concentrate discharge control valve and flow meters, performed well. Automation of the valve control integrated well with the control scheme and when used in concert with the other control variables, allowed automated control of the dual RMF system. The one area of concern with the instrumentation was the condition resulting when the filtrate flow meter operated with less than three gpm. This low flow was at the lower range of performance for the flow meter. This should not be

  13. Fluid Flow Phenomenon in a Three-Bladed Power-Generating Archimedes Screw Turbine

    Tineke Saroinsong; Rudy Soenoko; Slamet Wahyudi; Mega N Sasongko


    Experimental studies of the Archimedes screw turbine are applied as a micro hydro power plant for low head focused on the fluid flow. Fluid flow on a screw turbine is not completely filled water flow there is still a free surface between the water fluid and atmospheric air. Except the screw geometry, the turbine screw free surface allows the flow phenomena that are important in the process of turbine screw power generation. The Archimedes screw turbine main driving force is the fl...

  14. Fluid Flow Phenomenon in a Three-Bladed Power-Generating Archimedes Screw Turbine


    Experimental studies of the Archimedes screw turbine are applied as a micro hydro power plant for low head focused on the fluid flow. Fluid flow on a screw turbine is not completely filled water flow there is still a free surface between the water fluid and atmospheric air. Except the screw geometry, the turbine screw free surface allows the flow phenomena that are important in the process of turbine screw power generation. The Archimedes screw turbine main driving force is the fl...

  15. The Rotary Zone Thermal Cycler: A Low-Power System Enabling Automated Rapid PCR

    Bartsch, Michael S.; Renzi, Ronald F.; Van de Vreugde, James L.; Kim, Hanyoup; Knight, Daniel L.; Sinha, Anupama; Branda, Steven S.; Patel, Kamlesh D.


    Advances in molecular biology, microfluidics, and laboratory automation continue to expand the accessibility and applicability of these methods beyond the confines of conventional, centralized laboratory facilities and into point of use roles in clinical, military, forensic, and field-deployed applications. As a result, there is a growing need to adapt the unit operations of molecular biology (e.g., aliquoting, centrifuging, mixing, and thermal cycling) to compact, portable, low-power, and automation-ready formats. Here we present one such adaptation, the rotary zone thermal cycler (RZTC), a novel wheel-based device capable of cycling up to four different fixed-temperature blocks into contact with a stationary 4-microliter capillary-bound sample to realize 1-3 second transitions with steady state heater power of less than 10 W. We demonstrate the utility of the RZTC for DNA amplification as part of a highly integrated rotary zone PCR (rzPCR) system that uses low-volume valves and syringe-based fluid handling to automate sample loading and unloading, thermal cycling, and between-run cleaning functionalities in a compact, modular form factor. In addition to characterizing the performance of the RZTC and the efficacy of different online cleaning protocols, we present preliminary results for rapid single-plex PCR, multiplex short tandem repeat (STR) amplification, and second strand cDNA synthesis. PMID:25826708

  16. The rotary zone thermal cycler: a low-power system enabling automated rapid PCR.

    Michael S Bartsch

    Full Text Available Advances in molecular biology, microfluidics, and laboratory automation continue to expand the accessibility and applicability of these methods beyond the confines of conventional, centralized laboratory facilities and into point of use roles in clinical, military, forensic, and field-deployed applications. As a result, there is a growing need to adapt the unit operations of molecular biology (e.g., aliquoting, centrifuging, mixing, and thermal cycling to compact, portable, low-power, and automation-ready formats. Here we present one such adaptation, the rotary zone thermal cycler (RZTC, a novel wheel-based device capable of cycling up to four different fixed-temperature blocks into contact with a stationary 4-microliter capillary-bound sample to realize 1-3 second transitions with steady state heater power of less than 10 W. We demonstrate the utility of the RZTC for DNA amplification as part of a highly integrated rotary zone PCR (rzPCR system that uses low-volume valves and syringe-based fluid handling to automate sample loading and unloading, thermal cycling, and between-run cleaning functionalities in a compact, modular form factor. In addition to characterizing the performance of the RZTC and the efficacy of different online cleaning protocols, we present preliminary results for rapid single-plex PCR, multiplex short tandem repeat (STR amplification, and second strand cDNA synthesis.

  17. Percussive Augmenter of Rotary Drills for Operating as a Rotary-Hammer Drill

    Aldrich, Jack Barron (Inventor); Bar-Cohen, Yoseph (Inventor); Sherrit, Stewart (Inventor); Badescu, Mircea (Inventor); Bao, Xiaoqi (Inventor); Scott, James Samson (Inventor)


    A percussive augmenter bit includes a connection shaft for mounting the bit onto a rotary drill. In a first modality, an actuator percussively drives the bit, and an electric slip-ring provides power to the actuator while being rotated by the drill. Hammering action from the actuator and rotation from the drill are applied directly to material being drilled. In a second modality, a percussive augmenter includes an actuator that operates as a hammering mechanism that drives a free mass into the bit creating stress pulses that fracture material that is in contact with the bit.

  18. Gasoline New Timing and Flux Adjustable Rotary Valve Design (Hereinafter: Rotary Valve

    Du huiqi


    Full Text Available Conventional gasoline engine with an umbrella valve control cylinder intake and exhaust, in order to achieve sealing effect, the valve is driven by the spring force; at the same time, when the cam opens the valve to overcome the spring force acting. Sealing the better, the more power consumed in the engine mechanical losses, the valve mechanism consumes about 30%, which is not a small loss! This article describes a new type of rotary valve is to significantly reduce mechanical losses, so as to achieve energy saving purposes.

  19. Wet granulation in a twin-screw extruder: implications of screw design.

    Thompson, M R; Sun, J


    Wet granulation in twin-screw extrusion machinery is an attractive technology for the continuous processing of pharmaceuticals. The performance of this machinery is integrally tied to its screw design yet little fundamental knowledge exists in this emerging field for granulation to intelligently create, troubleshoot, and scale-up such processes. This study endeavored to systematically examine the influence of different commercially available screw elements on the flow behavior and granulation mechanics of lactose monohydrate saturated at low concentration (5-12%, w/w) with an aqueous polyvinyl-pyrrolidone binder. The results of the work showed that current screw elements could be successfully incorporated into designs for wet granulation, to tailor the particle size as well as particle shape of an agglomerate product. Conveying elements for cohesive granular flows were shown to perform similar to their use in polymer processing, as effective transport units with low specific mechanical energy input. The conveying zones provided little significant change to the particle size or shape, though the degree of channel fill in these sections had a significant influence on the more energy-intensive mixing elements studied. The standard mixing elements for this machine, kneading blocks and comb mixers, were found to be effective for generating coarser particles, though their mechanisms of granulation differed significantly.

  20. Posterior spinal fusion using pedicle screws.

    Athanasakopoulos, Michael; Mavrogenis, Andreas F; Triantafyllopoulos, George; Koufos, Spiros; Pneumaticos, Spiros G


    Few clinical studies have reported polyetheretherketone (PEEK) rod pedicle screw spinal instrumentation systems (CD-Horizon Legacy PEEK rods; Medtronic, Minneapolis, Minnesota). This article describes a clinical series of 52 patients who underwent posterior spinal fusion using the PEEK Rod System between 2007 and 2010. Of the 52 patients, 25 had degenerative disk disease, 10 had lateral recess stenosis, 6 had degenerative spondylolisthesis, 6 had lumbar spine vertebral fracture, 4 had combined lateral recess stenosis and degenerative spondylolisthesis, and 1 had an L5 giant cell tumor. Ten patients had 1-segment fusion, 29 had 2-segment fusion, and 13 had 3-segment fusion. Mean follow-up was 3 years (range, 1.5-4 years); no patient was lost to follow-up. Clinical evaluation was performed using the Oswestry Disability Index and a low back and leg visual analog pain scale. Imaging evaluation of fusion was performed with standard and dynamic radiographs. Complications were recorded. Mean Oswestry Disability Index scores improved from 76% preoperatively (range, 52%-90%) to 48% at 6 weeks postoperatively, and to 34%, 28%, and 30% at 3, 6, and 12 months postoperatively, respectively. Mean low back and leg pain improved from 8 and 9 points preoperatively, respectively, to 6 and 5 points immediately postoperatively, respectively, and to 2 points each thereafter. Imaging union of the arthrodesis was observed in 50 (96%) patients by 1-year follow-up. Two patients sustained screw breakage: 1 had painful loss of sagittal alignment of the lumbar spine and underwent revision spinal surgery with pedicle screws and titanium rods and the other had superficial wound infection and was treated with wound dressing changes and antibiotics for 6 weeks. No adjacent segment degeneration was observed in any patient until the time of this writing. Copyright 2013, SLACK Incorporated.

  1. Comparison between Bilateral C2 Pedicle Screwing and Unilateral C2 Pedicle Screwing, Combined with Contralateral C2 Laminar Screwing, for Atlantoaxial Posterior Fixation

    Miyakoshi, Naohisa; HONGO, MICHIO; Kobayashi, Takashi; Suzuki, Tetsuya; Abe, Eiji; Shimada, Yoichi


    Study Design A retrospective study. Purpose To compare clinical and radiological outcomes between bilateral C2 pedicle screwing (C2PS) and unilateral C2PS, combined with contralateral C2 laminar screwing (LS), for posterior atlantoaxial fixation. Overview of Literature Posterior fixation with C1 lateral mass screwing (C1LMS) and C2PS (C1LMS-C2PS method) is an accepted procedure for rigid atlantoaxial stabilization. However, conventional bilateral C2PS is not always allowed in this method due ...

  2. Trends toward rotary steerable directional systems

    Warren, T.M. [Amoco Exploration and Production Technology Group, Tulsa, OK (United States)


    Directional drilling will continue to be important in the petroleum industry for the foreseeable future as reserves in offshore locations, environmentally sensitive areas and locations with restricted surface access are developed. Emphasis on re-entries to extend the life of onshore and offshore production facilities and on horizontal completions to improve production rates and ultimate recovery will continue to place demands on directional drilling technology. Efficiency improvements that may be achieved through introduction of a new technology are often not easy to quantify, even though they may be quite significant. As long as the job gets done with the currently used system, and no better system is immediately available, it is natural to concentrate efforts on improving the existing system rather than introducing a new system. Here, the discussion is aimed at showing that drilling with steerable motor directional systems is inefficient, and that a significant improvement could be gained by introduction of rotary steerable systems. The objective of this article is not to put down motors, which have provided the backbone of directional drilling for three decades, but rather to show that considerable incentive exists for pursuing an alternative system.

  3. Dynamics of complex fluids in rotary atomization

    Keshavarz, Bavand; McKinley, Gareth; MIT, Mechanical Engineering Department Team


    We study the dynamics of fragmentation for different Newtonian and viscoelastic liquids in rotary atomization. In this process, at the rim of a spinning cup, the centripetal acceleration destabilizes the formed liquid torus due to the Rayleigh-Taylor instability. The resulting ligaments leave the liquid torus with a remarkably repeatable spacing that scales linearly with the inverse of the rotation rate. Filaments then follow a well-defined geometrical path-line that is described by the involute of the circle. Knowing the geometry of this phenomenon we derive the detailed kinematics of this process and compare it with the experimental observations. We show that the ligaments elongate tangentially to the involute of the circle and thin radially as they separate from the cup. A theoretical form is derived for the spatial variation of the filament deformation rate. Once the ligaments are far from the cup they breakup into droplets since they are not stretched fast enough (compared to the critical rate of capillary thinning). We couple these derivations with the known properties of Newtonian and viscoelastic liquids to provide a physical analysis for this fragmentation process that is compared in detail with our experiments.

  4. [Intraosseous screw splinting of mandibular fragments].

    Erle, A


    Fractures in the frontal region of the mandible may be treated by intra-ossal splinting without the risk of injuring nerves or vessels. Function-stable fixation of the reposited fragments was achieved in 15 patients by means of a transfragmental screw with metric thread. The advantages of this procedure consist in the easy removability of the material and the superfluidity of new developments of material or instruments. As the possibility of early functional treatment prevents the late impairment of the articular function, this procedure is particularly indicated in case of concurrent paramedian and articular fractures.

  5. Determination of the of rate cross slip of screw dislocations

    Vegge, Tejs; Rasmussen, Torben; Leffers, Torben;


    The rate for cross slip of screw dislocations during annihilation of screw dipoles in copper is determined by molecular dynamics simulations. The temperature dependence of the rate is seen to obey an Arrhenius behavior in the investigated temperature range: 225-375 K. The activation energy...

  6. Reliability of predictors for screw cutout in intertrochanteric hip fractures

    K.M.J. de Bruijn (Kirstin); D. den Hartog (Dennis); W.E. Tuinebreijer (Wim); G.R. Roukema (Gert)


    textabstractBackground: Following internal fixation of intertrochanteric hip fractures, tip apex distance, fracture classification, position of the screw in the femoral head, and fracture reduction are known predictors for screw cutout, but the reliability of these measurements is unknown. We invest



    Kinematics of a 3-RPS parallel pyramid manipulator are investigated by principal screw. Firstly, the principal screws are identified by quadric degeneration. The planar conics representing the relations between the pitches and the three linear inputs are described, and the three-dimensional distribution of the axes of all the twists is illustrated. Finally, a numerical example is given successfully.

  8. [Loosening of a Calcaneo-Stop Screw after Trampolining].

    Trieb, K; Fingernagel, T; Petershofer, A; Hofstaetter, S G


    Flexible flatfoot is a common malalignment in the paediatric population. Arthroereisis with a calcaneo-stop screw is an effective surgical procedure for treating juvenile flexible flatfoot after conservative measures have been fully exploited. In the present report, we describe the case of a loosening of a calcaneo-stop screw in a 12-year-old youth after excessive trampolining.


    Ching-KongChao; Chun-ChingHsiao; Po-QuangChen


    The effect of stress distribution due to the changes of the distal screw alignment in relation to the Gamma nail and the femoral shaft is thoroughly studied in this paper. Failure of the Gamma nail composite occurs through the cranial aperture of the distal screws and the insertion hole for the lag screw due to nonunion, delayed-union and continued weight-bearing. A three-dimensional finite element model was used to study the fractured femur, the Gamma nail, the lag screw and the distal locking screws. The first and the second distal screws were inserted into the Gamma nail in four different configurations. We found that the stress of the Gamma nail composite was substantially reduced with the two screws configured in the anterior to posterior direction. This alignment can bear greater loading in the more demanding fracture types. In the subtrochanteric fracture or the comminuted fractures at the proximal femur, the optimal alignment of the two distal screws was in the anterior to posterior direction.

  10. The Analysis of Soil Resistance During Screw Displacement Pile Installation

    Krasinski Adam


    Full Text Available The application of screw displacement piles (SDP is still increasing due to their high efficiency and many advantages. However, one technological problem is a serious disadvantage of those piles. It relates to the generation of very high soil resistance during screw auger penetration, especially when piles are installed in non-cohesive soils. In many situations this problem causes difficulties in creating piles of designed length and diameter. It is necessary to find a proper method for prediction of soil resistance during screw pile installation. The analysis of screw resistances based on model and field tests is presented in the paper. The investigations were carried out as part of research project, financed by the Polish Ministry of Science and Higher Education. As a result of tests and analyses the empirical method for prediction of rotation resistance (torque during screw auger penetration in non-cohesive subsoil based on CPT is proposed.

  11. On Helical Projection and Its Application in Screw Modeling

    Riliang Liu


    Full Text Available As helical surfaces, in their many and varied forms, are finding more and more applications in engineering, new approaches to their efficient design and manufacture are desired. To that end, the helical projection method that uses curvilinear projection lines to map a space object to a plane is examined in this paper, focusing on its mathematical model and characteristics in terms of graphical representation of helical objects. A number of interesting projective properties are identified in regard to straight lines, curves, and planes, and then the method is further investigated with respect to screws. The result shows that the helical projection of a cylindrical screw turns out to be a Jordan curve, which is determined by the screw's axial profile and number of flights. Based on the projection theory, a practical approach to the modeling of screws and helical surfaces is proposed and illustrated with examples, and its possible application in screw manufacturing is discussed.

  12. The Analysis of Soil Resistance During Screw Displacement Pile Installation

    Krasinski, Adam


    The application of screw displacement piles (SDP) is still increasing due to their high efficiency and many advantages. However, one technological problem is a serious disadvantage of those piles. It relates to the generation of very high soil resistance during screw auger penetration, especially when piles are installed in non-cohesive soils. In many situations this problem causes difficulties in creating piles of designed length and diameter. It is necessary to find a proper method for prediction of soil resistance during screw pile installation. The analysis of screw resistances based on model and field tests is presented in the paper. The investigations were carried out as part of research project, financed by the Polish Ministry of Science and Higher Education. As a result of tests and analyses the empirical method for prediction of rotation resistance (torque) during screw auger penetration in non-cohesive subsoil based on CPT is proposed.

  13. Ball Screw Actuator Including an Axial Soft Stop

    Wingett, Paul T. (Inventor); Forrest, Steven Talbert (Inventor); Abel, Steve (Inventor); Woessner, George (Inventor); Hanlon, Casey (Inventor)


    An actuator includes an actuator housing, a ball screw, and an axial soft stop assembly. The ball screw extends through the actuator housing and has a first end and a second end. The ball screw is coupled to receive a drive force and is configured, upon receipt of the drive force, to selectively move in a retract direction and an extend direction. The axial soft stop assembly is disposed within the actuator housing. The axial soft stop assembly is configured to be selectively engaged by the ball screw and, upon being engaged thereby, to translate, with compliance, a predetermined distance in the extend direction, and to prevent further movement of the ball screw upon translating the predetermined distance.

  14. A four lumen screwing device for multiparametric brain monitoring.

    Feuerstein, T H; Langemann, H; Gratzl, O; Mendelowitsch, A


    We describe multiparametric monitoring in severe head trauma using a new screwing device. Our aim was to create a screw which would make the implantation of the probes and thus multiparametric monitoring easier. The new screw allows us to implant 3 probes (microdialysis, Paratrend and an intracranial pressure device) through one burr hole. The screw has four channels, the fourth being for ventricular drainage. We monitored 13 patients with severe head trauma (GCS = 3-8) for up to 7 days. Brain tissue pO2, pCO2, pH, and temperature were measured on-line with the Paratrend 7 machine. The microdialytic parameters glucose, lactate, pyruvate and glutamate were determined semi on-line with a CMA 600 enzymatic analyser. There were no complications in any of the patients that could be ascribed to the screw.

  15. A new compression design that increases proximal locking screw bending resistance in femur compression nails.

    Karaarslan, Ahmet Adnan; Karakaşli, Ahmet; Karci, Tolga; Aycan, Hakan; Yildirim, Serhat; Sesli, Erhan


    The aim is to present our new method of compression, a compression tube instead of conventional compression screw and to investigate the difference of proximal locking screw bending resistance between compression screw application (6 mm wide contact) and compression tube (two contact points with 13 mm gap) application. We formed six groups each consisting of 10 proximal locking screws. On metal cylinder representing lesser trochanter level, we performed 3-point bending tests with compression screw and with compression tube. We determined the yield points of the screws in 3-point bending tests using an axial compression testing machine. We determined the yield point of 5 mm screws as 1963±53 N (mean±SD) with compression screw, and as 2929±140 N with compression tubes. We found 51% more locking screw bending resistance with compression tube than with compression screw (p=0,000). Therefore compression tubes instead of compression screw must be preferred at femur compression nails.

  16. Basic Study on Engine with Scroll Compressor and Expander

    Morishita, Etsuo; Kitora, Yoshihisa; Nishida, Mitsuhiro

    Scroll compressors are becoming popular in air conditioning and refrigeration. This is primarily due to their higher efficiency and low noise/vibration characteristics. The scroll principle can be applied also to the steam expander and the Brayton cycle engine,as shown in the past literature. The Otto cycle spark-ignition engine with a scroll compressor and expander is studied in this report. The principle and basic structure of the scroll engine are explained,and the engine characteristic are calculated based on the idealized cycles and processes. A prototype model has been proposed and constructed. The rotary type engine has always had a problem with sealing. The scroll engine might overcome this shortcoming with its much lower rubbing speed compared to its previous counterparts,and is therefore worth investigating.

  17. Supermassive screwed cosmic string in dilaton gravity

    Bezerra, V B [Departamento de Fisica, Universidade Federal da ParaIba, 58059-970, Joao Pessoa, PB (Brazil); Ferreira, Cristine N [Nucleo de Fisica, Centro Federal de Educacao Tecnologica de Campos, Rua Dr Siqueira, 273-Parque Dom Bosco, 28030-130, Campos dos Goytacazes, RJ (Brazil); Cuesta, H J Mosquera [Instituto de Cosmologia, Relatividade e AstrofIsica (ICRA-BR), Centro Brasileiro de Pesquisas Fisicas, Rua Dr Xavier Sigaud 150, Urca 22290-180, Rio de Janeiro, RJ (Brazil)


    The early universe might have undergone phase transitions at energy scales much higher than the one corresponding to the grand unified theories (GUT) scales. At these higher energy scales, the transition at which gravity separated from all other interactions, the so-called Planck era, more massive strings called supermassive cosmic strings could have been produced, with energy of about 10{sup 19} GeV. The dynamics of strings formed with this energy scale cannot be described by means of the weak-field approximation, as in the standard procedure for ordinary GUT cosmic strings. As suggested by string theories, at this extreme energy, gravity may be transmitted by some kind of scalar field (usually called the dilaton) in addition to the tensor field of Einstein's theory of gravity. It is then permissible to tackle the issue regarding the dynamics of supermassive cosmic strings within this framework. With this aim, we obtain the gravitational field of a supermassive screwed cosmic string in a scalar-tensor theory of gravity. We show that for the supermassive configuration, exact solutions of scalar-tensor screwed cosmic strings can be found in connection with the Bogomol'nyi limit. We show that the generalization of Bogomol'nyi arguments to the Brans-Dicke theory is possible when torsion is present and we obtain an exact solution in this supermassive regime, with the dilaton solution obtained by consistency with internal constraints.

  18. Lumbar pedicle cortical bone trajectory screw

    Song Tengfei; Wellington K Hsu; Ye Tianwen


    Objective The purpose of this study was to demonstrate the lumbar pedicle cortical bone trajectory (CBT) screw fixation technique,a new fixation technique for lumbar surgery.Data sources The data analyzed in this review are mainly from articles reported in PubMed published from 1994 to 2014.Study selection Original articles and critical reviews relevant to CBT technique and lumbar pedicle fixation were selected.Results CBT technique was firstly introduced as a new fixation method for lumbar pedicle surgery in 2009.The concepts,morphometric study,biomechanical characteristics and clinical applications of CBT technique were reviewed.The insertional point of CBT screw is located at the lateral point of the pars interarticularis,and its trajectory follows a caudocephalad path sagittally and a laterally directed path in the transverse plane.CBT technique can be used for posterior fixation during lumbar fusion procedures.This technique is a minimally invasive surgery,which affords better biomechanical stability,fixation strength and surgical safety.Therefore,CBT technique has the greatest benefit in lumbar pedicle surgery for patients with osteoporosis and obesity.Conclusion CBT technique is a better alternative option of lumbar pedicle fixation,especially for patients with osteoporosis and obesity.

  19. Asymmetric distribution in twin screw granulation.

    Chan Seem, Tim; Rowson, Neil A; Gabbott, Ian; de Matas, Marcel; Reynolds, Gavin K; Ingram, Andy


    Positron Emission Particle Tracking (PEPT) was successfully employed to validate measured transverse asymmetry in material distribution in the conveying zones of a Twin Screw Granulator (TSG). Flow asymmetry was established to be a property of the granulator geometry and dependent on fill level. The liquid distribution of granules as a function of fill level was determined. High flow asymmetry at low fill level negatively affects granule nucleation leading to high variance in final uniformity. Wetting of material during nucleation was identified as a critical parameter in determining final granule uniformity and fill level is highlighted as a crucial control factor in achieving this. Flow asymmetry of dry material in conveying zones upstream of binder fluid injection leads to poor non-uniform wetting at nucleation and results in heterogeneous final product. The granule formation mechanism of 60°F kneading blocks is suggested to be primarily breakage of agglomerates formed during nucleation. Optimisation of screw configuration would be required to provide secondary growth. This work shows how fill dependent flow regimes affect granulation mechanisms.

  20. Planar Rotary Piezoelectric Motor Using Ultrasonic Horns

    Sherrit, Stewart; Bao, Xiaoqi; Badescu, Mircea; Bar-Cohen, Yoseph; Geiyer, Daniel; Ostlund, Patrick N.; Allen, Phillip


    A motor involves a simple design that can be embedded into a plate structure by incorporating ultrasonic horn actuators into the plate. The piezoelectric material that is integrated into the horns is pre-stressed with flexures. Piezoelectric actuators are attractive for their ability to generate precision high strokes, torques, and forces while operating under relatively harsh conditions (temperatures at single-digit K to as high as 1,273 K). Electromagnetic motors (EM) typically have high rotational speed and low torque. In order to produce a useful torque, these motors are geared down to reduce the speed and increase the torque. This gearing adds mass and reduces the efficiency of the EM. Piezoelectric motors can be designed with high torques and lower speeds directly without the need for gears. Designs were developed for producing rotary motion based on the Barth concept of an ultrasonic horn driving a rotor. This idea was extended to a linear motor design by having the horns drive a slider. The unique feature of these motors is that they can be designed in a monolithic planar structure. The design is a unidirectional motor, which is driven by eight horn actuators, that rotates in the clockwise direction. There are two sets of flexures. The flexures around the piezoelectric material are pre-stress flexures and they pre-load the piezoelectric disks to maintain their being operated under compression when electric field is applied. The other set of flexures is a mounting flexure that attaches to the horn at the nodal point and can be designed to generate a normal force between the horn tip and the rotor so that to first order it operates independently and compensates for the wear between the horn and the rotor.

  1. Simulation and Optimization of Contactless Power Transfer System for Rotary Ultrasonic Machining

    Wang Xinwei


    Full Text Available In today’s rotary ultrasonic machining (RUM, the power transfer system is based on a contactless power system (rotary transformer rather than the slip ring that cannot cope with high-speed rotary of the tool. The efficiency of the rotary transformer is vital to the whole rotary ultrasonic machine. This paper focused on simulation of the rotary transformer and enhancing the efficiency of the rotary transformer by optimizing three main factors that influence its efficiency, including the gap between the two ferrite cores, the ratio of length and width of the ferrite core and the thickness of ferrite. The finite element model of rotary transformer was built on Maxwell platform. Simulation and optimization work was based on the finite element model. The optimization results compared with the initial simulation result showed an approximate 18% enhancement in terms of efficiency, from 77.69% to 95.2%.

  2. Forehead tissue expander.

    Kisner, W H


    The use of the forehead flap for nasal reconstruction has long been used by reconstructive surgeons. A case is presented in which comprised forehead skin is utilized following expansion by a tissue expander.

  3. Operator in-the-loop control of rotary cranes

    Parker, G.G.; Robinett, R.D.; Driessen, B.J.; Dohrmann, C.R.


    An open-loop control method is presented for reducing the oscillatory motion of rotary crane payloads during operator commanded maneuvers. A typical rotary crane consists of a multiple degree-of-freedom platform for positioning a spherical pendulum with an attached payload. The crane operator positions the Payload by issuing a combination of translational and rotational commands to the platform as well as load-line length changes. Frequently, these pendulum modes are time-varying and exhibit low natural frequencies. Maneuvers are therefore performed at rates sufficiently slow so as not to excite oscillation. The strategy presented here generates crane commands which suppress vibration of the payload without a priori knowledge of the desired maneuver. Results are presented for operator in-the-loop positioning using a real-time dynamics simulation of a three-axis rotary crane where the residual sway magnitude is reduced in excess of 4OdB.

  4. FEM simulation of infeed rotary swaging with structured tools

    Herrmann Marius


    Full Text Available Rotary swaging is an incremental cold forming process for rods and tubes. Infeed rotary swaging with structure in the reduction zone of the tools is investigated using a two dimensional finite element simulation. A few geometrical parameters are varied, for cosine and skew stairway shapes. The effective tool angle is kept constant. The influence is evaluated by the radial and axial process forces. Furthermore, the material flow is visualized by the neutral plane. The simulation results are quantitatively compared to each other to analyse the reaction force FA, which acts against the feeding force. Also, the results serve to find suitable geometries to be transferred to rotary swaging tools for practical application. It is shown that the shapes have a significant effect on the forces and the location of the neutral plane. Finally a first swaging tool is modified with an exemplary geometry for experimental investigations.

  5. Behavioral changes in preschoolers treated with/without rotary instruments.

    Maru, Viral Pravin; Kumar, Amit; Badiyani, Bhumika Kamal; Sharma, Anant Raghav; Sharma, Jitendra; Dobariya, Chintan Vinodbhai


    Behavioral dentistry is an interdisciplinary science which needs to be learned, practiced, and reinforced in order to provide quality dental care in children. To assess the anxiety experienced during dental treatment in preschool children with/without rotary instruments using behavioral scale. Sixty pediatric patients of preschool age with bilateral occlusal carious lesions extending into dentin were selected for the study. Carious lesions were removed using conventional rotary instruments on one side and Papacarie - chemomechanical caries removal of approach on contra lateral side. Both cavities were restored with glass ionomer cement (Fuji IX). Anxiety scores were determined using 'Modified Child Dental Anxiety Scale' (Wong et al, 1998) during the various clinical stages of the treatment course. Children experienced relaxed behavior when subjected to Papacarie method of caries removal compared to conventional method using rotary instruments. This study helped us to provide behavioral measures and introduce children to dentistry in a nonthreatening setting.

  6. Simulation Study on Fuzzy Control of Rotary Steering Drilling Trajectory

    Xue Qi-Long


    Full Text Available The purpose of this study is to establish a control method to make borehole trajectory smoother. Considering that the complexity of rotary steerable drilling trajectory control and uncertainty of underground work, analysis of the deficiencies for the traditional trajectory control and the rotary steerable drilling trajectory deviation vector control theory, introduced the concept of "trend Angle", combined with the deviation vector as joint control variables, using fuzzy control algorithm that established of rotary steerable drilling trajectory fuzzy control model. Designed the fuzzy controller using Matlab/Simulink toolbox and dynamic simulation analysis for the fuzzy control systems, simulation results show that the designed fuzzy controller can effectively track the well path design, has a strong adaptability and control results is better than traditional PID control method.

  7. Rotary plug device for use in LMFBR type reactors

    Azuma, Kazuhiko; Imayoshi, Sho.


    Purpose: To prevent adhesion of sodium in the rotational gap of a rotational plug. Constitution: One of the walls of a cylindrical gap formed between the outer circumference of a small rotary plug and a large rotary plug that constitute a double rotary plug is cooled to lower than the sodium coagulation temperature, while a stater of a linear motor in a cylindrical shape and wound with linear coils around the iron core is attached to the inside of the other of the walls. Then, one of the walls of the gap to which sodium adheres is cooled to less than sodium coagulation temperature, so that sodium is or tends to be deposited to the wall. Then, eddy currents are resulted to sodium by the current supplied to the stater of the linear motor attached to the other of the walls, to produce thrusting force. Sodium on the wall surface is scraped off by this. (Yoshihara, H.).

  8. Soybean drying characteristics in microwave rotary dryer with forced convection

    Ruifang WANG; Zhanyong LI; Yanhua LI; Jingsheng YE


    A new hybrid drying technique by combining microwave and forced convection drying within a rotary drum, i.e., microwave rotary drying, was developed with the purpose to improve the uniformity of microwave drying. In a laboratory microwave rotary dryer, rewetted soybean was utilized as experimental material to study the effects of drum rotating speed, ventilation flow rate, and specific microwave power on the drying kinetics and cracking ratio of soybean. It was found that, with rotation, the cracking ratio can be lowered but without distinct improvement in the drying rate. Increasing ventilation flow rate and specific microwave power can improve the drying rate, but the cracking ratio also increases as a negative result. The cracking ratio lower than 10% can be attained for ventilation flow rate lower than 2.0 m3·h-1 or specific microwave energy lower than 0.4 kW·kg-1 in the present experiments.

  9. Economics of water injected air screw compressor systems

    Venu Madhav, K.; Kovačević, A.


    There is a growing need for compressed air free of entrained oil to be used in industry. In many cases it can be supplied by oil flooded screw compressors with multi stage filtration systems, or by oil free screw compressors. However, if water injected screw compressors can be made to operate reliably, they could be more efficient and therefore cheaper to operate. Unfortunately, to date, such machines have proved to be insufficiently reliable and not cost effective. This paper describes an investigation carried out to determine the current limitations of water injected screw compressor systems and how these could be overcome in the 15-315 kW power range and delivery pressures of 6-10 bar. Modern rotor profiles and approach to sealing and cooling allow reasonably inexpensive air end design. The prototype of the water injected screw compressor air system was built and tested for performance and reliability. The water injected compressor system was compared with the oil injected and oil free compressor systems of the equivalent size including the economic analysis based on the lifecycle costs. Based on the obtained results, it was concluded that water injected screw compressor systems could be designed to deliver clean air free of oil contamination with a better user value proposition than the oil injected or oil free screw compressor systems over the considered range of operations.

  10. Positioning of pedicle screws in adolescent idiopathic scoliosis using electromyography

    Bruno Moreira Gavassi


    Full Text Available OBJECTIVE: To analyze the occurrence of poor positioning of pedicle screws inserted with the aid of intraoperative electromyographic stimulation in the treatment of Adolescent Idiopathic Scoliosis (AIS.METHODS: This is a prospective observational study including all patients undergoing surgical treatment for AIS, between March and December 2013 at a single institution. All procedures were monitored by electromyography of the inserted pedicle screws. The position of the screws was evaluated by assessment of postoperative CT and classified according to the specific AIS classification system.RESULTS: Sixteen patients were included in the study, totalizing 281 instrumented pedicles (17.5 per patient. No patient had any neurological deficit or complaint after surgery. In the axial plane, 195 screws were found in ideal position (69.4% while in the sagittal plane, 226 screws were found in ideal position (80.4%. Considering both the axial and the sagittal planes, it was observed that 59.1% (166/281 of the screws did not violate any cortical wall.CONCLUSION: The use of pedicle screws proved to be a safe technique without causing neurological damage in AIS surgeries, even with the occurrence of poor positioning of some implants.

  11. Engineering Aspects of Single- and Twin-screw Extrusion-cooking of Biopolymers

    Zuilichem, D.J. van; Stolp, W.; Janssen, L.P.B.M.


    A survey is given of the properties of single- and twin-screw extruders. The influence on the design of the different leakage gaps existing in co-rotating, counter-rotating, self-wiping, twin-screw extruders and single-screw equipment is discussed. The mixing effects in single- and twin-screw equipm

  12. 16 CFR 1205.5 - Walk-behind rotary power mower controls.


    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Walk-behind rotary power mower controls... rotary power mower controls. (a) Blade control systems—(1) Requirements for blade control. A walk-behind rotary power mower shall have a blade control system that will perform the following functions:...

  13. Evaluation of different rotary devices on bone repair in rabbits

    Ribeiro Junior, Paulo Domingos; Barleto, Christiane Vespasiano; Ribeiro,Daniel Araki; Matsumoto,Mariza Akemi


    In oral surgery, the quality of bone repair may be influenced by several factors that can increase the morbidity of the procedure. The type of equipment used for ostectomy can directly affect bone healing. The aim of this study was to evaluate bone repair of mandible bone defects prepared in rabbits using three different rotary devices. Fifteen New Zealand rabbits were randomly assigned to 3 groups (n=5) according to type of rotary device used to create bone defects: I - pneumatic low-speed r...

  14. Development of Laser Propelled ``Semi-Perpetual'' Rotary Machine

    Gualini, M. M.; Khan, S. A.; Zulfiqar, K.


    This paper covers the initial work oriented to develop a semi-perpetual rotary machine propelled by laser ablation propulsion. The laser is equipped with a pulse repetition frequency tuned to the rotational frequency of the flying wheel. Purpose of this work is to establish the potentiality of a self-sustained closed system capable of generating kinetic rotary energy which can be exploited for traction of vehicles and production of electrical energy at very low cost. The work presented is in process of being patented.

  15. Study of a Novel Rotary Cyclone Gas-Solid Separator

    Zhiguang Ling; Xingyong Deng


    Based on the analytical study of the characteristics of fine particle motion in swirling flow, a new design idea on flow organization and construction aimed at increasing the positive radial flow in the separation chamber of the rotary cyclone separator (PRV type) was proposed. Experimental verification including the test of variation of separation efficiency and pressure loss with the first and secondary flow ratio show that this new type separator has higher and more stable separation efficiency in broad flow ratio range while the pressure loss is far below the conventional rotary cyclone separator and even comparable with that of simple cyclone separator

  16. Preliminary Design on Screw Press Model of Palm Oil Extraction Machine

    Firdaus, Muhammad; Salleh, S. M.; Nawi, I.; Ngali, Z.; Siswanto, W. A.; Yusup, E. M.


    The concept of the screw press is to compress the fruit bunch between the main screw and travelling cones to extract the palm oil. Visual inspection, model development and simulation of screw press by using Solidworks 2016 and calculation of design properties were performed to support the investigation. The project aims to analyse different design of screw press which improves in reducing maintenance cost and increasing lifespan. The currently existing of screw press can endure between 500 to 900 hours and requires frequent maintenance. Different configurations have been tried in determination of best design properties in screw press. The results specify that screw press with tapered inner shaft has more total lifespan (hours) compared existing screw press. The selection of the screw press with tapered inner shaft can reduce maintenance cost and increase lifespan of the screw press.

  17. A power recirculating test rig for ball screw endurance tests

    Giberti Hermes


    Full Text Available A conceptual design of an innovative test rig for endurance tests of ball screws is presented in this paper. The test rig layout is based on the power recirculating principle and it also allows to overtake the main critical issues of the ball screw endurance tests. Among these there are the high power required to make the test, the lengthy duration of the same and the high loads between the screw and the frame that holds it. The article describes the test rig designed scheme, the kinematic expedients to be adopted in order to obtain the required performance and functionality and the sizing procedure to choose the actuation system.

  18. Electromagnetic Lead Screw for Potential Wave Energy Application

    Lu, Kaiyuan; Wu, Weimin


    This paper presents a new type electromagnetic lead screw (EMLS) intended for wave energy application. Similar to the mechanical lead screw, this electromagnetic version can transfer slow linear motion to high-rotational motion, offering gearing effects. Compared with the existing pure magnetic...... lead screw (MLS) employing permanent magnets only, the new EMLS proposed uses dc current to provide the required helical-shape magnetic field, offering a much simpler, robust structure compared with the MLS. The working principle and the performances of this EMLS are analyzed in this paper. Comparison...

  19. Migration of polyethylene fixation screw after total knee arthroplasty.

    Cho, Woo-Shin; Youm, Yoon-Seok


    Duracon (Howmedica, Rutherford, NJ) posterior stabilized total knee system has a snap fit locking mechanism of a tibial polyethylene, including an additional locking screw for further fixation of polyethylene. We report 13 cases of locking screw migration from tibial component after Duracon posterior stabilized primary total knee arthroplasty. Among 13 knees, screw migration in 10 asymptomatic cases was incidentally detected during regular follow-up, and they were just observed in the outpatient clinic. Only 3 knees had moderate pain, swelling, and instability, and revision was done on 2 of 3 knees.

  20. Test Research on Special Sucker Rod for Screw Pump

    Zhang Mingyi; Chen Mingzhan; Li Zhi


    @@ According to the statistics of straight thread sucker rods' application in screw pump in Daqing Oilfield before2000, the proportion of sucker rods' yearly breakaway reached to 41.6%, taking up 70% of the total wells that were checked. Thus it can be seen that the rods breakaway problem was becoming the main barrier restricting screw pump large-scale population and application. Since then,the development work on the special sucker rods for screw pump had been carried on. Through the analysis on the failure position and failure form of the sucker rods',the following conclusions arepresented:

  1. Simulation and analysis of resin flow in injection machine screw

    Ling-feng LI; Samir MEKID


    A method with simulation and analysis of the resin flow in a screw is presented to ease the control of some problems that may affect the efficiency and the quality of the product among existing screws in an injection machine. The physical model of a screw is established to represent the stress, the strain, the relationship between velocity and stress, and the temperature of the cells. In this paper, a working case is considered where the velocity and the temperature distributions at any section of the flow are obtained. The analysis of the computational results shows an ability to master various parameters depending on the specifications.

  2. Noninvasive method for retrieval of broken dental implant abutment screw

    Jagadish Reddy Gooty


    Full Text Available Dental implants made of titanium for replacement of missing teeth are widely used because of ease of technical procedure and high success rate, but are not free of complications and may fail. Fracturing of the prosthetic screw continues to be a problem in restorative practice and great challenge to remove the fractured screw conservatively. This case report describes and demonstrates the technique of using an ultrasonic scaler in the removal of the fracture screw fragment as a noninvasive method without damaging the hex of implants.

  3. On Expanded Cyclic Codes

    Wu, Yingquan


    The paper has a threefold purpose. The first purpose is to present an explicit description of expanded cyclic codes defined in $\\GF(q^m)$. The proposed explicit construction of expanded generator matrix and expanded parity check matrix maintains the symbol-wise algebraic structure and thus keeps many important original characteristics. The second purpose of this paper is to identify a class of constant-weight cyclic codes. Specifically, we show that a well-known class of $q$-ary BCH codes excluding the all-zero codeword are constant-weight cyclic codes. Moreover, we show this class of codes achieve the Plotkin bound. The last purpose of the paper is to characterize expanded cyclic codes utilizing the proposed expanded generator matrix and parity check matrix. We analyze the properties of component codewords of a codeword and particularly establish the precise conditions under which a codeword can be represented by a subbasis. With the new insights, we present an improved lower bound on the minimum distance of...

  4. Silicon microfabricated beam expander

    Othman, A.; Ibrahim, M. N.; Hamzah, I. H.; Sulaiman, A. A.; Ain, M. F.


    The feasibility design and development methods of silicon microfabricated beam expander are described. Silicon bulk micromachining fabrication technology is used in producing features of the structure. A high-precision complex 3-D shape of the expander can be formed by exploiting the predictable anisotropic wet etching characteristics of single-crystal silicon in aqueous Potassium-Hydroxide (KOH) solution. The beam-expander consist of two elements, a micromachined silicon reflector chamber and micro-Fresnel zone plate. The micro-Fresnel element is patterned using lithographic methods. The reflector chamber element has a depth of 40 µm, a diameter of 15 mm and gold-coated surfaces. The impact on the depth, diameter of the chamber and absorption for improved performance are discussed.

  5. Silicon microfabricated beam expander

    Othman, A., E-mail:; Ibrahim, M. N.; Hamzah, I. H.; Sulaiman, A. A. [Faculty of Electrical Engineering, Universiti Teknologi MARA Malaysia, 40450, Shah Alam, Selangor (Malaysia); Ain, M. F. [School of Electrical and Electronic Engineering, Engineering Campus, Universiti Sains Malaysia, Seri Ampangan, 14300,Nibong Tebal, Pulau Pinang (Malaysia)


    The feasibility design and development methods of silicon microfabricated beam expander are described. Silicon bulk micromachining fabrication technology is used in producing features of the structure. A high-precision complex 3-D shape of the expander can be formed by exploiting the predictable anisotropic wet etching characteristics of single-crystal silicon in aqueous Potassium-Hydroxide (KOH) solution. The beam-expander consist of two elements, a micromachined silicon reflector chamber and micro-Fresnel zone plate. The micro-Fresnel element is patterned using lithographic methods. The reflector chamber element has a depth of 40 µm, a diameter of 15 mm and gold-coated surfaces. The impact on the depth, diameter of the chamber and absorption for improved performance are discussed.

  6. Note: A novel rotary actuator driven by only one piezoelectric actuator.

    Huang, Hu; Fu, Lu; Zhao, Hongwei; Shi, Chengli; Ren, Luquan; Li, Jianping; Qu, Han


    This paper presents a novel piezo-driven rotary actuator based on the parasitic motion principle. Output performances of the rotary actuator were tested and discussed. Experiment results indicate that using only one piezoelectric actuator and simple sawtooth wave control, the rotary actuator reaches the rotation velocity of about 20,097 μrad/s when the driving voltage is 100 V and the driving frequency is 90 Hz. The actuator can rotate stably with the minimum resolution of 0.7 μrad. This paper verifies feasibility of the parasitic motion principle for applications of rotary actuators, providing new design ideas for precision piezoelectric rotary actuators.




    Full Text Available Profiled steel sheet dry boards or PSSDB system is an alternative composite construction system comprising of profiled steel sheet compositely connected to dry boards by self-tapping self-driving screws. PSSDB system was used widely as flooring system in the lightweight construction of buildings and office space in factories. Due to its superiority in the installation techniques, PSSDB system was expanded in the application as load bearing wall panel system in buildings. The PSSDB system is as an alternative construction technique on load bearing wall panel that offers cost savings synonymously with the rapid progress of science and technology which leads to the shift from traditional utilization of construction materials to newer construction techniques. A finite element analysis was carried out to determine the effect of screw spacing on the PSSDB wall panel. The spacing selected was between 100 mm to 500 mm, at an increment of 100 mm in each different model. The wall panel measured 3000 mm by 3000 mm with a 1200 mm square window opening, 78 mm thick and butt joints vertically positioned in the dry boards. This paper looks into the system as load bearing wall panels, analyzing it under axial compressive load using established Finite Element technique. The deformation profile of the PSSDB wall panel system showed a single curvature deformation profile, maximum lateral displacement at two-thirds wall panel height and critical sections at the upper corners of the square opening. The finite element analysis had provided good prediction of the structural behavior of the PSSDB wall panel system and it is concluded that the PW200 model possesses the optimum arrangement of the fixing screws used.

  8. Centrifuging Step-Screw Conveyor for Regolith Project

    National Aeronautics and Space Administration — A variety of ISRU operations will utilize lunar regolith as feedstock. The proposed centrifuging step-screw conveyor concept will provide a well controlled robust,...

  9. Kinematic analysis of parallel manipulators by algebraic screw theory

    Gallardo-Alvarado, Jaime


    This book reviews the fundamentals of screw theory concerned with velocity analysis of rigid-bodies, confirmed with detailed and explicit proofs. The author additionally investigates acceleration, jerk, and hyper-jerk analyses of rigid-bodies following the trend of the velocity analysis. With the material provided in this book, readers can extend the theory of screws into the kinematics of optional order of rigid-bodies. Illustrative examples and exercises to reinforce learning are provided. Of particular note, the kinematics of emblematic parallel manipulators, such as the Delta robot as well as the original Gough and Stewart platforms are revisited applying, in addition to the theory of screws, new methods devoted to simplify the corresponding forward-displacement analysis, a challenging task for most parallel manipulators. Stands as the only book devoted to the acceleration, jerk and hyper-jerk (snap) analyses of rigid-body by means of screw theory; Provides new strategies to simplify the forward kinematic...

  10. Biomechanical analysis of titanium fixation plates and screws in ...

    Key words: Bone plates, bone screws, finite element analysis, jaw fixation techniques, mandible, mandibular .... model is built up, in similar way to building block construction, .... shows advantages, such as granting intraoral route, minimal.

  11. Lumbar pedicle screw placement: Using only AP plane imaging

    Anil Sethi


    Conclusion: Placement of pedicle screws under fluoroscopic guidance using AP plane imaging alone with tactile guidance is safe, fast, and reliable. However, a good understanding of the radiographic landmarks is a prerequisite.

  12. Intermaxillary Fixation Screw Morbidity in Treatment of Mandibular Fractures

    Florescu, Vlad-Andrei; Kofod, Thomas; Pinholt, Else Marie


    Surgery, Rigshospitalet, University Hospital of Copenhagen, Copenhagen, Denmark). The fracture type, radiographic findings, treatment modality, screw type and number, and root damage were recorded. For the outcome comparison, a review of the published data regarding iatrogenic dental root damage caused......Purpose The aim of the present retrospective study was to investigate the morbidity of screws used for intermaxillary fixation (IMF) in the treatment of mandibular fractures. A review of the published data was also performed for a comparison of outcomes. Our hypothesis was that the use of screws...... for IMF of mandibular fractures would result in minimal morbidity. Materials and Methods Patients treated for mandibular fractures from 2007 to 2013, using screws for IMF, using the international diagnosis code for mandibular fracture, DS026, were anonymously selected (Department of Oral and Maxillofacial...

  13. Surfzone monitoring using rotary wing unmanned aerial vehicles

    Brouwer, R.L.; De Schipper, M.A.; Rynne, P.F.; Graham, F.J.; Reniers, A.J.H.M.; Macmahan, J.H.


    This study investigates the potential of rotary wing unmanned aerial vehicles (UAVs) to monitor the surfzone. This paper shows that these UAVs are extremely flexible surveying platforms that can gather nearcontinuous moderate spatial resolution and high temporal resolution imagery from a fixed posit

  14. RICOR development of the next generation highly reliable rotary cryocooler

    Regev, Itai; Nachman, Ilan; Livni, Dorit; Riabzev, Sergey; Filis, Avishai; Segal, Victor


    Early rotary cryocoolers were designed for the lifetime of a few thousands operating hours. Ricor K506 model's life expectancy was only 5,000 hours, then the next generation K508 model was designed to achieve 10,000 operating hours in basic conditions, while the modern K508N was designed for 20,000 operating hours. Nowadays, the new challenges in the field of rotary cryocoolers require development of a new generation cooler that could compete with the linear cryocooler reliability, achieving the lifetime goal of 30,000 operating hours, and even more. Such new advanced cryocooler can be used for upgrade existing systems, or to serve the new generation of high-temperature detectors that are currently under development, enabling the cryocooler to work more efficiently in the field. The improvement of the rotary cryocooler reliability is based on a deep analysis and understating of the root failure causes, finding solutions to reduce bearings wear, using modern materials and lubricants. All of those were taken into consideration during the development of the new generation rotary coolers. As a part of reliability challenges, new digital controller was also developed, which allows new options, such as discrete control of the operating frequency, and can extend the cooler operating hours due to new controlling technique. In addition, the digital controller will be able to collect data during cryocooler operation, aiming end of life prediction.

  15. Improved performance of linear coal cutting compared with rotary cutting

    Roepke, W.W.; Hanson, B.D.; Olson, R.C.; Wingquist, C.F.; Myren, T.A.


    The linear cutting system, developed by the US Bureau of Mines uses geometric principles developed by Cardan to produce a nearly constant cut depth. The new system has been extensively tested in a synthetic material under laboratory conditions to verify mechanical capability and to identify operational characteristics. Comparison between 15-rpm linear cutting and 50-rpm rotary cutting systems show significant improvement in respirable dust entrainment, product size distribution, and energy usage. Respirable dust is reduced by as much as 90%. Recovered product showed a 67% reduction in {minus}0.32-cm ({minus}1/8-in) material and a 200% increase in +5.08 cm (+ 2 in) materials. Average power was reduced by 66% for the linear cutting. Because the bit cutting paths differ between linear and rotary cutting, it was necessary to compare the two at the same cut depths and bit types. These comparisons show that low revolution per minute rotary cutting entrains about the same amount of respirable dust as the linear cutting system, but the average shaft torque may be 55 to 130% greater for the rotary system.

  16. Mass transfer in rolling rotary kilns : a novel approach

    Heydenrych, M.D.; Greeff, P.; Heesink, A. Bert M.; Versteeg, G.F.


    A novel approach to modeling mass transfer in rotary kilns or rotating cylinders is explored. The movement of gas in the interparticle voids in the bed of the kiln is considered, where particles move concentrically with the geometry of the kiln and gas is entrained by these particles. The approach c

  17. Lignite chemical conversion in an indirect heat rotary kiln gasifier

    Hatzilyberis Kostas S.


    Full Text Available The results on the gasification of Greek lignite using two indirect heat (allothermal pilot rotary kiln gasifiers are reported in the present work. The development of this new reactor-gasifier concept intended for solid fuels chemical conversion exploits data and experience gained from the following two pilot plants. The first unit A (about 100 kg/h raw lignite demonstrated the production of a medium heating value gas (12-13 MJ/Nm3 with quite high DAF (dry ash free coal conversions, in an indirect heat rotary gasifier under mild temperature and pressure conditions. The second unit B is a small pilot size unit (about 10 kg/h raw lignite comprises an electrically heated rotary kiln, is an operation flexible and exhibits effective phase mixing and enhanced heat transfer characteristics. Greek lignite pyrolysis and gasification data were produced from experiments performed with pilot plant B and the results are compared with those of a theoretical model. The model assumes a scheme of three consecutive-partly parallel processes (i. e. drying, pyrolysis, and gasification and predicts DAF lignite conversion and gas composition in relatively good agreement with the pertinent experimental data typical of the rotary kiln gasifier performance. Pilot plant B is currently being employed in lime-enhanced gasification studies aiming at the production of hydrogen enriched synthesis gas. Presented herein are two typical gas compositions obtain from lignite gasification runs in the presence or not of lime. .

  18. Micro rotary machine and methods for using same

    Stalford, Harold L [Norman, OK


    A micro rotary machine may include a micro actuator and a micro shaft coupled to the micro actuator. The micro shaft comprises a horizontal shaft and is operable to be rotated by the micro actuator. A micro tool is coupled to the micro shaft and is operable to perform work in response to motion of the micro shaft.

  19. Control of spatial correlations between Rydberg excitations using rotary echo

    Thaicharoen, N; Raithel, G


    We manipulate correlations between Rydberg excitations in cold atom samples using a rotary-echo technique. The correlations are due to interactions between the Rydberg atoms. In the rotary-echo excitation sequence, the phase of the excitation pulse is flipped at a selected time during the pulse. We measure the resultant change in the spatial pair correlation function of the excitations via direct position-sensitive atom imaging. For zero detuning of the lasers from the interaction-free Rydberg-excitation resonance, the pair-correlation value at the most likely nearest-neighbor Rydberg-atom distance is substantially enhanced when the phase is flipped at the middle of the excitation pulse. In this case, the rotary echo eliminates most uncorrelated (un-paired) atoms, leaving an abundance of correlated atom pairs at the end of the sequence. In off-resonant cases, a complementary behavior is observed. We further characterize the effect of the rotary-echo excitation sequence on the excitation-number statistics of t...

  20. Equivalent Circuit Modeling of a Rotary Piezoelectric Motor

    El, Ghouti N.; Helbo, Jan


    In this paper, an enhanced equivalent circuit model of a rotary traveling wave piezoelectric ultrasonic motor "shinsei type USR60" is derived. The modeling is performed on the basis of an empirical approach combined with the electrical network method and some simplification assumptions about...

  1. Rotary ATPases: models, machine elements and technical specifications.

    Stewart, Alastair G; Sobti, Meghna; Harvey, Richard P; Stock, Daniela


    Rotary ATPases are molecular rotary motors involved in biological energy conversion. They either synthesize or hydrolyze the universal biological energy carrier adenosine triphosphate. Recent work has elucidated the general architecture and subunit compositions of all three sub-types of rotary ATPases. Composite models of the intact F-, V- and A-type ATPases have been constructed by fitting high-resolution X-ray structures of individual subunits or sub-complexes into low-resolution electron densities of the intact enzymes derived from electron cryo-microscopy. Electron cryo-tomography has provided new insights into the supra-molecular arrangement of eukaryotic ATP synthases within mitochondria and mass-spectrometry has started to identify specifically bound lipids presumed to be essential for function. Taken together these molecular snapshots show that nano-scale rotary engines have much in common with basic design principles of man made machines from the function of individual "machine elements" to the requirement of the right "fuel" and "oil" for different types of motors.


    Oana CHIVU


    Full Text Available The present paper is concerned with the main modeling elements as produced by means of thefinite element method of rotary ultrasonic motors. Hence, first the model is designed and then a modaland harmonic analysis are carried out in view of outlining the main outcomes

  3. Light-Driven Rotary Molecular Motors on Gold Nanoparticles

    Pollard, Michael M.; ter Wiel, Matthijs K. J.; van Delden, Richard A.; Vicario, Javier; Koumura, Nagatoshi; van den Brom, Coenraad R.; Meetsma, Auke; Feringa, Ben L.


    We report the synthesis of unidirectional light-driven rotary molecular motors based oil chiral overcrowded alkenes and their immobilisation on the surface of gold nanoparticles through two anchors. Using a combination of (1)H and (13)C NMR, UV/Vis and CD spectroscopy, we show that these motors pres

  4. Chemically Optimizing Operational Efficiency of Molecular Rotary Motors

    Conyard, Jamie; Cnossen, Arjen; Browne, Wesley R.; Feringa, Ben L.; Meech, Stephen R.


    Unidirectional molecular rotary motors that harness photoinduced cis-trans (E-Z) isomerization are promising tools for the conversion of light energy to mechanical motion in nanoscale molecular machines. Considerable progress has been made in optimizing the frequency of ground-state rotation, but le

  5. ZrO2-Containing Refractories for Cement Rotary Kilns

    YE Guotian; XU Yanqing


    ZrO2-containing refractories have been increasingly used for cement rotary kilns. This paper discusses how the properties and performance of ZrO2-containing. Refractories are inwroved in terms of chemical attack resistance, thermal shock resistance, thermal conductivity and mechanical stress.

  6. Surfzone monitoring using rotary wing unmanned aerial vehicles

    Brouwer, R.L.; De Schipper, M.A.; Rynne, P.F.; Graham, F.J.; Reniers, A.J.H.M.; Macmahan, J.H.


    This study investigates the potential of rotary wing unmanned aerial vehicles (UAVs) to monitor the surfzone. This paper shows that these UAVs are extremely flexible surveying platforms that can gather nearcontinuous moderate spatial resolution and high temporal resolution imagery from a fixed

  7. Design and control of a Nitinol wire actuated rotary servo

    Song, G.


    This paper presents the design and control of a rotary servo actuated by a shape memory alloy (SMA) wire. A new rotary servo device using Nitinol type of SMA wire is designed and fabricated in this study. This new rotary actuator utilizes a Nitinol wire wound on a threaded non-conductive rotor. One end of the Nitinol wire is fixed to the rotor and the other end is fixed to the supporting base plate. The rotor is connected to a pre-tensioned torsional spring such that two-way rotation can be achieved. Upon heating of the Nitinol wire using electric current, the wire contracts, causing the rotor to rotate, since the other end of the SMA wire is rigidly connected to the base plate. This rotor design is compact and offers a space-saving solution for the use of SMA wire actuators. To actively control the servo, a sliding-mode based robust control approach is used. The sliding-mode based robust control consists of three components: a standard proportional plus derivative (PD) control term, a feedforward term used as a bias current, and a robust term to increase system stability and concurrently control accuracy. Experimental results confirm the functionality of the Nitinol wire actuated rotary servo and show this device can be precisely controlled using the sliding-mode based robust control approach.

  8. Numerical Analysis on Rotary Forging Mechanism of a Flange


    A numerical simulation on the rotary forging process of a flange is conducted by three-dimensional rigid-plastic finite element method. The states of stress and strain rate in the workpiece are analyzed and the forging mechanism of the flange is revealed. Moreover, the influence of the die configuration on the material flow is also analyzed.

  9. Expanding mediation theory

    Verbeek, P.P.C.C.


    In his article In Between Us, Yoni van den Eede expands existing theories of mediation into the realm of the social and the political, focusing on the notions of opacity and transparency. His approach is rich and promising, but two pitfalls should be avoided. First, his concept of ‘in-between’ runs

  10. Expanding Student Assessment Opportunities.

    Bartscher, Beth; Carter, Andrea; Lawlor, Anna; McKelvey, Barbara

    This paper describes an approach for expanding assessment opportunities for students to demonstrate their understanding of content. The targeted population consisted of elementary and junior high school students in two schools in a growing middle-class community in north central Illinois. The elementary school enrolled 467 students and the junior…

  11. Pullout strength of misplaced pedicle screws in the thoracic and lumbar vertebrae - A cadaveric study

    Shyam K Saraf


    Full Text Available Background: The objective of this cadaveric study was to analyze the effects of iatrogenic pedicle perforations from screw misplacement on the mean pullout strength of lower thoracic and lumbar pedicle screws. We also investigated the effect of bone mineral density (BMD, diameter of pedicle screws, and the region of spine on the pullout strength of pedicle screws. Materials and Methods: Sixty fresh human cadaveric vertebrae (D10-L2 were harvested. Dual-energy X-ray absorptiometry (DEXA scan of vertebrae was done for BMD. Titanium pedicle screws of different diameters (5.2 and 6.2 mm were inserted in the thoracic and lumbar segments after dividing the specimens into three groups: a standard pedicle screw (no cortical perforation; b screw with medial cortical perforation; and c screw with lateral cortical perforation. Finally, pullout load of pedicle screws was recorded using INSTRON Universal Testing Machine. Results: Compared with standard placement, medially misplaced screws had 9.4% greater mean pullout strength and laterally misplaced screws had 47.3% lesser mean pullout strength. The pullout strength of the 6.2 mm pedicle screws was 33% greater than that of the 5.2 mm pedicle screws. The pullout load of pedicle screws in lumbar vertebra was 13.9% greater than that in the thoracic vertebra ( P = 0.105, but it was not statistically significant. There was no significant difference between pullout loads of vertebra with different BMD ( P = 0.901. Conclusion: The mean pullout strength was less with lateral misplaced pedicle screws while medial misplaced pedicle screw had more pullout strength. The pullout load of 6.2 mm screws was greater than that of 5.2 mm pedicle screws. No significant correlation was found between bone mineral densities and the pullout strength of vertebra. Similarly, the pullout load of screw placed in thoracic and lumbar vertebrae was not significantly different.

  12. Rapid prototyping drill guide template for lumbar pedicle screw placement

    LU Sheng; XU Yong-qing; ZHANG Yuan-zhi; LI Yan-bing; SHI Ji-hong; CHEN Guo-ping; CHEN Yu-bing


    To develop a novel method of spinal pedical stereotaxy by reverse engineering and rapid prototyping techniques, and to validate its accuracy by experimental and clinical studies. Methods: A 3D reconstruction model for the desired lumbar vertebra was generated by using the Mimics 10.11 software, and the optimal screw size and orientation were determined using the reverse engineering software. Afterwards, a drill template was created by reverse engi-neering principle, whose surface was the antitemplate of the vertebral surface. The drill template and its correspond-ing vertebra were manufactured using the rapid prototyping technique. Results: The accuracy of the drill template was con-firmed by drilling screw trajectory into the vertebral biomodel preoperatively. This method also showed its ability to cus-tomize the placement and size of each screw based on the unique morphology of the lumbar vertebra.The drill tem-plate fits the postural surface of the vertebra very well in the cadaver experiment. Postoperative CT scans for controlling the pedicle bore showed that the personalized template had a high precision in cadaver experiment and clinical application. No misplacement occurred by using the per-sonalized template. During surgery, no additional computer assistance was needed.Conclusions: The authors have developed a novel drill template for lumbar pedicle screw placement with good applicability and high accuracy. The potential use of drill templates to place lumbar pedicle screws is promising. Our methodology appears to provide an accurate technique and trajectory for pedicle screw placement in the lumbar spine.

  13. Pedicle screw fixation against burst fracture of thoracolumbar vertebrae

    L(U) Fu-xin; HUANG Yong; ZHANG Qiang; SHI Feng-lei; ZHAO Dong-sheng; HU Qiao


    Objective: To analyze the application of vertebral pedicle screw fixation in the treatment of burst fracture of thoracolumbar vertebrae.Methods: A total of 48 cases (31 males and 17 females, aged from 18-72 years, mean: 41.3 years) with thoracolumbar vertebrae burst fracture were treated by pedicle screw system since January 2004. According to the AO classification of thoracolumbar vertebrae fracture,there are 36 cases of Type A, 9 of Type B and 3 of Type C.Results: All patients were followed up for 6-25 months (average 12 months ), no secondary nerve root injury, spinal cord injury, loosening or breakage of pedicle screw were observed. The nerve function of 29 patients with cauda equina nerve injury was restored to different degrees. The vertebral body height returned to normal level and posterior process angle was rectified after operation.Conclusions: The vertebral pedicle screw internal fixation was technologically applicable, which can efficiently reposition and stablize the bursting fractured vertabrae,indirectly decompress canalis spinalis, maintain spine stablity, scatter stress of screw system, reduce the risk of loosening or breakage of screw and loss of vertebral height,and prevent the formation of posterior convex after operation.

  14. Bending strength and holding power of tibial locking screws.

    Lin, J; Lin, S J; Chiang, H; Hou, S M


    The bending strength and holding power of two types of specially designed tibial locking devices, a both-ends-threaded screw and an unthreaded bolt, were studied and compared with four types of commercially available tibial interlocking screws: Synthes, Howmedica, Richards, and Osteo AG. To test bending strength, the devices were inserted into a high molecular weight polyethylene tube and loaded at their midpoint by a materials testing machine to simulate a three point bending test. Single loading yielding strength and cyclic loading fatigue life were measured. To test holding power, the devices were inserted into tubes made of polyurethane foam, and their tips were loaded axially to measure pushout strength. The devices were tested with two different densities of foam materials and two different sizes of pilot holes. Insertion torque and stripping torque of the screws were measured first. Pushout tests were performed with each screw inserted with a tightness equal to 60% of its stripping torque. Test results showed that the yielding strength and the fatigue life were related closely to the inner diameter of the screws. The stripping torque predicted the pushout strength more reliably than did the insertion torque. All tested devices showed greater holding power in the foam with the higher density and with the smaller pilot holes. The both-ends-threaded screw had the highest pushout strength and a satisfactory fatigue strength. The unthreaded bolt had the highest fatigue strength but only fair holding power. Clinical studies of the use of these two types of locking devices are worthwhile.

  15. Far cortical locking screws in distal femur fractures.

    Adams, John D; Tanner, Stephanie L; Jeray, Kyle J


    Distal femur fractures routinely heal by secondary bone healing, which relies on interfragmentary motion. Periarticular locking plates are commonly used for fixation in distal femur fractures but are associated with a high nonunion rate, likely due to the stiffness of the constructs. Far cortical locking (FCL) screws are designed to allow micromotion at the near cortex while maintaining purchase in only the far cortex. Although clinical data are limited, these screws have been shown in biomechanical studies to provide excellent interfragmentary motion, and animal models have shown increased callus formation compared with traditional locking screws. The purpose of this study was to examine the clinical effects that FCL screws have on healing in distal femur fractures treated with locked constructs. In this retrospective case series, 15 patients with a distal femur fracture treated with MotionLoc screws (Zimmer, Warsaw, Indiana) were analyzed. Serial radiographs were evaluated for callus presence and time to union. All fractures were either 33-A3 or 33-C2 according to the AO classification system, and 5 (33%) were open. Bone loss was recorded in 2 patients. There were no nonunions, and average time to union was 24 weeks. There were no implant failures, and all 5 open fractures, including the 2 with bone loss, healed without intervention. There was 1 reoperation due to painful hardware. Although this is a small case series, these results are promising. Far cortical locking screws may provide the answer to the high nonunion rate associated with distal femur fractures treated with traditional locked constructs.

  16. Robot-assisted Anterior Odontoid Screw Fixation: A Case Report.

    Tian, Wei; Wang, Han; Liu, Ya-Jun


    Anterior odontoid screw fixation has been proved to be effective but technically challenging because the difficult approach is associated with high risks of screw malposition and damage to surrounding vital structures. Navigation techniques are therefore increasingly being used to improve safety and accuracy. However, no robot-assisted odontoid screw fixation has yet been reported. We here report a 61-year-old woman with a type II dens fracture on whom anterior odontoid screw fixation was performed under the guidance of a newly developed robotic system (TiRobot, co-designed by Beijing Jishuitan Hospital and TINAVI Medical Technologies). One odontoid screw was safely and accurately placed, the calculated deviation between the planned and actual positions being 0.9 mm. No intraoperative complications were identified and the patient was discharged on Day 5. Follow-up studies after 2 weeks showed good clinical and radiological results. We believe this is the first reported case of robot-assisted anterior odontoid screw fixation. We consider that complicated procedures can become feasible, safe and accurate using TiRobot systems.

  17. Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study

    Herrera Antonio


    Full Text Available Abstract Background Primary stability of the graft is essential in anterior cruciate ligament surgery. An optimal method of fixation should be easy to insert and provide great resistance against pull-out forces. A controlled laboratory study was designed to test the primary stability of ACL tendinous grafts in the tibial tunnel. The correlation between resistance to traction forces and the cross-section and length of the screw was studied. Methods The tibial phase of ACL reconstruction was performed in forty porcine tibias using digital flexor tendons of the same animal. An 8 mm tunnel was drilled in each specimen and two looped tendons placed as graft. Specimens were divided in five groups according to the diameter and length of the screw used for fixation. Wedge interference screws were used. Longitudinal traction was applied to the graft with a Servohydraulic Fatigue System. Load and displacement were controlled and analyzed. Results The mean loads to failure for each group were 295,44 N (Group 1; 9 × 23 screw, 564,05 N (Group 2; 9 × 28, 614,95 N (Group 3; 9 × 35, 651,14 N (Group 4; 10 × 28 and 664,99 (Group 5; 10 × 35. No slippage of the graft was observed in groups 3, 4 and 5. There were significant differences in the load to failure among groups (ANOVA/P Conclusions Longer and wider interference screws provide better fixation in tibial ACL graft fixation. Short screws (23 mm do not achieve optimal fixation and should be implanted only with special requirements.

  18. Prediction of Deformity Correction by Pedicle Screw Instrumentation in Thoracolumbar Scoliosis Surgery

    Kiriyama, Yoshimori; Yamazaki, Nobutoshi; Nagura, Takeo; Matsumoto, Morio; Chiba, Kazuhiro; Toyama, Yoshiaki

    In segmental pedicle screw instrumentation, the relationship between the combinations of pedicle screw placements and the degree of deformity correction was investigated with a three-dimensional rigid body and spring model. The virtual thoracolumbar scoliosis (Cobb’s angle of 47 deg.) was corrected using six different combinations of pedicle-screw placements. As a result, better correction in the axial rotation was obtained with the pedicle screws placed at or close to the apical vertebra than with the screws placed close to the end vertebrae, while the correction in the frontal plane was better with the screws close to the end vertebrae than with those close to the apical vertebra. Additionally, two screws placed in the convex side above and below the apical vertebra provided better correction than two screws placed in the concave side. Effective deformity corrections of scoliosis were obtained with the proper combinations of pedicle screw placements.

  19. Three-dimensional comparison of alternative screw positions versus actual fixation of scaphoid fractures.

    Volk, Ido; Gal, Jonathan; Peleg, Eran; Almog, Gil; Luria, Shai


    The recommended technique for the fixation of a scaphoid waist fracture involves a headless compression screw placed in the proximal fragment center. This is usually accomplished by placing a longitudinal axis screw as visualized by fluoroscopy. The screw length has been shown to have a biomechanical advantage. An alternative to these options, which has been debated in the literature, is a screw placed perpendicular to the fracture plane and in its center. The perpendicular screw may have a biomechanical advantage despite the fact that it may be shorter. This study examined the differences in location and length in actual patients between a screw in the center of the proximal fragment with a longitudinal axis screw, and the actual fixating screw. These were then compared to a perpendicular axis screw. Pre- and post-operative CT scans of 10 patients with scaphoid waist fractures were evaluated using a 3D computer model. Comparisons were made between the length, location and angle of actual and virtual screw alternatives; namely, a screw along the central third of the proximal fragment (central screw axis) where the scaphoid longitudinal axis was calculated mathematically (longitudinal screw axis) and a screw placed at 90° to the fracture plane and in its center (perpendicular screw axis). The longitudinal axis screw was found to be significantly longer than the other axes (28.3mm). There was a significant difference between the perpendicular axis screw and the location and angle of the other screw axis, but it was only shorter than the longitudinal screw (23.6mm versus 25.5mm for the actual screw; ns.). A computed longitudinal axis screw is longer than a central or actual screw placed longitudinally by visual inspection by the surgeon. Although it needs to be placed using computer assisted (CAS) techniques, it may have the biomechanical advantages of a longer screw in a similar trajectory. The perpendicular screw was found to be significantly different in position

  20. Effect of management practices on screw-worm among sheep in São Paulo State, Brazil.

    Madeira, N G; Amarante, A F; Padovani, C R


    The screw-worm Cochliomyia hominivorax (Coquerel), whose larvae develop in wild and domestic animals as well as in man, is one of the major causes of myiasis in Brazil. Sheep raising is expanding in the state of São Paulo, where information about the infestation of screw-worm is necessary for appropriate control measures. The present data were obtained from questionnaires sent to all sheep breeders belonging to Associacão Paulista de Criadores de Ovinos--ASPACO (São Paulo State Association of Sheep Breeders). Response reliability was tested by random visits paid to 10.6% of the respondents. The results show that screw-worm is the most frequent ectoparasite in the flocks and is responsible for the greatest economic losses. Its occurrence is strongly associated with flock size, reaching 100% in flocks consisting of more than 500 animals. Infestation is higher in spring and summer and lowest in the fall. The number of cases increases in the presence of some management practices such as tail amputation. Furthermore, several other associations between the indicators surveyed were also found to be significant. The data obtained will permit the elaboration of strategies for the control of this parasitosis.

  1. Two-phase screw-type engine - problems of the filling process; Zweiphasen-Schraubenmotor - Probleme des Fuellungsvorganges

    Kauder, K.; Kliem, B. [Dortmund Univ. (Germany). FG Fluidenergiemaschinen


    The two-phase screw-type engine presents itself as a expansion engine in a trilateral-flash-cycle to use waste heat in the lower temperature range, because this displacement engine is able to expand working fluids with a high proportion of liquid. Due to the low critical velocity and the blocking flow, the two-phase flow in the inlet port of the screw-type engine has a great influence on the quality of energy transformation. A novel filling system with rotating short nozzles is presented. Less dissipation during the filling process is expected by this system, because the flash evaporation of the fluid will occur in the working chamber and not in the inlet port of the screw-type engine. (orig.) [Deutsch] Der Zweiphasen-Schraubenmotor besitzt als Expansionsmaschine in Trilateral-Flash-Cycle-Prozessen zur Nutzung von Abwaerme mit niedriger Temperatur deutliche Vorteile, da dieser Maschinentyp in der Lage ist, Arbeitsfluide mit einem hohen Fluessigkeitsanteil zu expandieren. Die Zweiphasenstroemung im Einlassbereich des Schraubenmotors hat aufgrund ihrer geringen kritischen Geschwindigkeit und der damit verbundenen blockierten Stroemung einen signifikanten Einfluss auf die Fuellung der Arbeitskammer und der Energiewandlungsguete des Motors. Ein hier vorgestelltes neuartiges Fuellungssystem mit rotierenden Kurzduesen laesst eine verbesserte Fuellung des Zweiphasen-Schraubenmotors erwarten, da es erst in den Arbeitskammern zur Flashverdampfung kommt. (orig.)

  2. Usefulness of absorbable screws in the Sauvé-Kapandji procedure for rheumatoid wrist reconstruction.

    Nakamura, K; Oda, H; Tanaka, S; Kuga, Y; Yamamoto, M; Nishikawa, T; Juji, T; Shimizu, M


    Abstract  In the Sauvé-Kapandji (S-K) procedure for rheumatoid wrist reconstruction, the distal end of the ulna is fixed to the radius with screws. Recently, absorbable screws have increasingly been used instead of metal ones. However, the clinical usefulness of absorbable screws in S-K procedures for rheumatoid patients is still unknown. The purpose of this article is to evaluate the effect of absorbable screws in this procedure by comparing their clinical results with those of metal screws. Poly-l-lactic acid (PLLA) absorbable screws were used in 23 wrists, and metal screws were used in 20 wrists. We evaluated the presence of general or local reactions to PLLA, the stability of the ulnar head, the time to bone union, changes in the shape of the distal ulna, and the presence of bone resorption around the screws. There were no complications with the use of PLLA screws, and their fixation stability was adequate to form sufficient bone union. In five cases in the metal screw group, bone resorption around the screws occurred between 1 and 2 years after surgery. Bone resorption around the PLLA screws was not observed. We conclude that absorbable screws may be more useful than metal screws in the S-K procedure for rheumatoid wrist reconstruction.

  3. Biomechanical analysis of pedicle screw density in spinal instrumentation for scoliosis treatment: first results.

    Wang, Xiaoyu; Aubin, Carl-Eric; Larson, A Noelle; Labelle, Hubert; Parent, Stefan


    Clinical studies reveal remarkable variation in screw patterns, or screw density in spinal instrumentation. Screw density may have a great impact on blood loss, operative time, radiation, risk of screw malposition, and cost. Thus, there is a need to understanding of the biomechanical effects of screw density so as to minimize the number of pedicle screws while ensuring safe and effective instrumentation. The objective of this study was to compare the deformity correction effects and bone-screw loadings of different pedicle screw densities in spinal instrumentation for scoliosis treatment. Spinal instrumentation simulations were performed on three scoliosis patients using 3 screw density patterns (low, preferred, and high screw density) proposed by two experienced surgeons and basic correction techniques: concave rod attachment, rod derotation, apical vertebral derotation, and convex side rod attachment. Simulation results showed that all tested screw densities generated quite similar correction, with differences between the achieved corrections all below 3°. The average bone-screw forces were 244±67N, 214±66 N, and 210±71 N, respectively for low, preferred, and high densities. It remains a complex challenge balancing the benefit of load sharing between more implants with the overconstraints and limited degrees of freedom introduced by the increased number of implants. Studies on additional screw densities and patterns proposed by more surgeons for a variety of cases, and using more diverse correction techniques are necessary to draw stronger conclusions and to recommend the optimal screw density.

  4. Development and Testing of X-Ray Imaging-Enhanced Poly-L-Lactide Bone Screws.

    Wei-Jen Chang

    Full Text Available Nanosized iron oxide particles exhibit osteogenic and radiopaque properties. Thus, iron oxide (Fe3O4 nanoparticles were incorporated into a biodegradable polymer (poly-L-lactic acid, PLLA to fabricate a composite bone screw. This multifunctional, 3D printable bone screw was detectable on X-ray examination. In this study, mechanical tests including three-point bending and ultimate tensile strength were conducted to evaluate the optimal ratio of iron oxide nanoparticles in the PLLA composite. Both injection molding and 3D printing techniques were used to fabricate the PLLA bone screws with and without the iron oxide nanoparticles. The fabricated screws were implanted into the femoral condyles of New Zealand White rabbits. Bone blocks containing the PLLA screws were resected 2 and 4 weeks after surgery. Histologic examination of the surrounding bone and the radiopacity of the iron-oxide-containing PLLA screws were evaluated. Our results indicated that addition of iron oxide nanoparticles at 30% significantly decreased the ultimate tensile stress properties of the PLLA screws. The screws with 20% iron oxide exhibited strong radiopacity compared to the screws fabricated without the iron oxide nanoparticles. Four weeks after surgery, the average bone volume of the iron oxide PLLA composite screws was significantly greater than that of PLLA screws without iron oxide. These findings suggested that biodegradable and X-ray detectable PLLA bone screws can be produced by incorporation of 20% iron oxide nanoparticles. Furthermore, these screws had significantly greater osteogenic capability than the PLLA screws without iron oxide.

  5. Ipsilateral pedicle screw placement with contralateral percutaneous facet screws: Early results with an alternative in lumbar arthrodesis

    Richard B Rhiew


    Full Text Available Richard B Rhiew, Sunil Manjila, Andrew M Lozen, David Hong, Murali Guthikonda, S S RengacharyDepartment of Neurosurgery, Wayne State University, Detroit, MI, USAAbstract: Transforaminal lumbar interbody fusion (TLIF is a widely used method of surgical treatment for a variety of lumbar spinal disorders. Bilateral transpedicular instrumentation is routinely used in conjunction with an interbody graft to provide additional stability. In this technical note, we describe our fusion construct using ipsilateral pedicle screw placement on the side of TLIF and contralateral facet screw placement. We performed this construct at six levels in four patients. Suggested advantages include: low morbidity, small incision and lower cost. Outcomes parameters included radiographic evidence of solid union at four months and improvement in Oswestry Disability Index. A mean improvement from a preoperative score of 73 to 26 after surgery was observed at one-year follow-up. There were no instrument-related complications. In conclusion, this hybrid screw system minimizes contralateral dissection and is an attractive alternative to standard bilateral pedicle screw fixation.Keywords: TLIF, facet screw, pedicle screw, lumbar spine fusion

  6. The influence of screw configuration on the pretreatment performance of a continuous twin screw-driven reactor (CTSR).

    Choi, Chang Ho; Um, Byung-Hwan; Oh, Kyeong Keun


    A combination of a continuous twin screw-driven reactor (CTSR) and a dilute acid pretreatment was used for the pretreatment of biomass with a high cellulose content and high monomeric xylose hydrolyzate. With the newly modified CTSR screw configuration (Config. 3), the influences of the screw rotational speed (30-60 rpm), of the pretreatment conditions such as acid concentration (1-5%) and reaction temperature (160-175 °C) at the operating condition of biomass feeding rate (1.0 g/min) and acid feeding rate (13.4 mL/min) on the pretreatment performance were investigated. The cellulose content in the pretreated rape straw was 67.1% at the following optimal conditions: barrel temperature of 165 °C, acid concentration of 3.0% (w/v), and screw rotational speed of 30 rpm. According to the three screw configurations, the glucose yields from enzymatic hydrolysis were 70.1%, 72.9%, and 78.7% for screw Configs. 1, 2, and 3, respectively.

  7. Investigation of an 11mm diameter twin screw granulator: Screw element performance and in-line monitoring via image analysis.

    Sayin, Ridade; Martinez-Marcos, Laura; Osorio, Juan G; Cruise, Paul; Jones, Ian; Halbert, Gavin W; Lamprou, Dimitrios A; Litster, James D


    As twin screw granulation (TSG) provides one with many screw element options, characterization of each screw element is crucial in optimizing the screw configuration in order to obtain desired granule attributes. In this study, the performance of two different screw elements - distributive feed screws and kneading elements - was studied in an 11 mm TSG at different liquid-to-solid (L/S) ratios. The kneading element configuration was found to break large granules more efficiently, leading to narrower granule size distributions. While pharmaceutical industry shifts toward continuous manufacturing, inline monitoring and process control are gaining importance. Granules from an 11 mm TSG were analysed using the Eyecon™, a real-time high speed direct imaging system, which has been used to capture accurate particle size distribution and particle count. The size parameters and particle count were then assessed in terms of their ability to be a suitable control measure using the Shewhart control charts. d10 and particle count were found to be good indicators of the change in L/S ratio. However, d50 and d90 did not reflect the change, due to their inherent variability even when the process is at steady state.

  8. Grazing incidence beam expander

    Akkapeddi, P.R.; Glenn, P.; Fuschetto, A.; Appert, Q.; Viswanathan, V.K.


    A Grazing Incidence Beam Expander (GIBE) telescope is being designed and fabricated to be used as an equivalent end mirror in a long laser resonator cavity. The design requirements for this GIBE flow down from a generic Free Electron Laser (FEL) resonator. The nature of the FEL gain volume (a thin, pencil-like, on-axis region) dictates that the output beam be very small. Such a thin beam with the high power levels characteristic of FELs would have to travel perhaps hundreds of meters or more before expanding enough to allow reflection from cooled mirrors. A GIBE, on the other hand, would allow placing these optics closer to the gain region and thus reduces the cavity lengths substantially. Results are presented relating to optical and mechanical design, alignment sensitivity analysis, radius of curvature analysis, laser cavity stability analysis of a linear stable concentric laser cavity with a GIBE. Fabrication details of the GIBE are also given.

  9. Expanding the HAWC Observatory

    Mori, Johanna [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)


    The High Altitude Water Cherenkov Gamma-Ray Observatory is expanding its current array of 300 water tanks to include 350 outrigger tanks to increase sensitivity to gamma rays above 10 TeV. This involves creating and testing hardware with which to build the new tanks, including photomultiplier tubes, high voltage supply units, and flash analog to digital converters. My responsibilities this summer included preparing, testing and calibrating that equipment.

  10. Sacroiliac secure corridor: analysis for safe insertion of iliosacral screws

    Henrique Alves Cruz


    Full Text Available OBJECTIVE: Posterior pelvic lesions, especially of the sacral-iliac joint, have high mortality and morbidity risks. Definitive fixation is necessary for the joint stabilization, and one option is the sacral percutaneous pinning with screws. Proximity to important structures to this region brings risks to the fixation procedure; therefore, it is important to know the tridimensional anatomy of the pelvis posterior region. Deviations of the surgeon's hand of four degrees may target the screws to those structures; dimorphisms of the upper sacrum and a poor lesion reduction may redound in a screw malpositioning. This study is aimed to evaluate the dimensions of a safe surgical corridor for safe sacroiliac screw insertion and relations with age and sex of the patients. METHOD: One hundred randomly selected pelvis CTs of patients with no pelvic diseases, seen at a tertiary care teaching Hospital. Measurements were made by computer and the safest area for screw insertion was calculated by two methods. The results were expressed in mm (not in degrees, in order to be a further surgical reference. RESULTS: There was a significant size difference in the analyzed sacral vertebra, differing on a wider size in men than in women. There was no significant statistical difference between vertebral size and age. By both methods, a safe area for screw insertion could be defined. CONCLUSION: Age does not influence the width of the surgical corridor. The surgeon has a safe corridor considered narrower when inserting screws in a female pelvis than when in a male one. However, as the smallest vertebra found (feminine was considered for statics, it was concluded that this corridor is 20 mm wide in any direction, taking as a reference the centrum of the vertebra.

  11. Evaluation of roundness error using a new method based on a small displacement screw

    Nouira, Hichem; Bourdet, Pierre


    In relation to industrial need and the progress of technology, LNE would like to improve the measurement of its primary pressure, spherical and flick standards. The spherical and flick standards are respectively used to calibrate the spindle motion error and the probe which equips commercial conventional cylindricity measuring machines. The primary pressure standards are obtained using pressure balances equipped with rotary pistons with an uncertainty of 5 nm for a piston diameter of 10 mm. Conventional machines are not able to reach such an uncertainty level. That is why the development of a new machine is necessary. To ensure such a level of uncertainty, both stability and performance of the machine are not sufficient, and the data processing should also be done with accuracy less than a nanometre. In this paper, a new method based on the small displacement screw (SDS) model is proposed. A first validation of this method is proposed on a theoretical dataset published by the European Community Bureau of Reference (BCR) in report no 3327. Then, an experiment is prepared in order to validate the new method on real datasets. Specific environment conditions are taken into account and many precautions are considered. The new method is applied to analyse the least-squares circle, minimum zone circle, maximum inscribed circle and minimum circumscribed circle. The results are compared to those done by the reference Chebyshev best-fit method and reveal perfect agreement. The sensibilities of the SDS and Chebyshev methodologies are investigated, and it is revealed that results remain unchanged when the value of the diameter exceeds 700 times the form error.

  12. Output characteristics of floating type wave power generator system using a ball screw; Fuyugata nejishiki haryoku hatsuden sochi no shutsuryoku tokusei

    Abe, T.; Omata, K. [Meiji University, Tokyo (Japan)


    A floating type wave power generator system using a ball screw is proposed. Output characteristics are simulated on the supposition of its employment aboard a navigational aid buoy. The relative linear movement produced by waves between the main body and float is transmitted via a load column to a ball nut and is converted into a rotary movement of a threaded shaft engaging the ball nut. Attached to the bottom end of the threaded shaft is a one-way clutch which connects to the generator axle when the relative velocity between the float and main body is positive. The simulation was conducted for a wave activated power generation buoy, 2.6m in outer diameter, 4.5m in length, and 6000kg in total mass. The buoy generated a mechanical output of 340kW when exposed to a sinusoidal wave 2.5 seconds in period and 40cm in wave height. A tank test was performed using a reduced scale model consisting of a ball screw, bicycle dynamo, and float, with the main body being 318mm in diameter and 833mm in length, when an average output of 4.51W was obtained at 60% efficiency. The results of the experiment agreed in some degree with the results of calculation, verifying the righteousness of the theoretical formula. 3 refs., 7 figs., 4 tabs.

  13. Preoperative CT planning of screw length in arthroscopic Latarjet.

    Hardy, Alexandre; Gerometta, Antoine; Granger, Benjamin; Massein, Audrey; Casabianca, Laurent; Pascal-Moussellard, Hugues; Loriaut, Philippe


    The Latarjet procedure has shown its efficiency for the treatment of anterior shoulder dislocation. The success of this technique depends on the correct positioning and fusion of the bone block. The length of the screws that fix the bone block can be a problem. They can increase the risk of non-union if too short or be the cause of nerve lesion or soft tissue discomfort if too long. Suprascapular nerve injuries have been reported during shoulder stabilisation surgery up to 6 % of the case. Bone block non-union depending on the series is found around 20 % of the cases. The purpose of this study was to evaluate the efficiency of this CT preoperative planning to predict optimal screws length. The clinical importance of this study lies in the observation that it is the first study to evaluate the efficiency of CT planning to predict screw length. Inclusion criteria were patients with chronic anterior instability of the shoulder with an ISIS superior to 4. Exclusion criteria were patients with multidirectional instability or any previous surgery on this shoulder. Thirty patients were included prospectively, 11 of them went threw a CT planning, before their arthroscopic Latarjet. Optimal length of both screws was calculated, adding the size of the coracoid at 5 and 15 mm from the tip to the glenoid. Thirty-two-mm screws were used for patients without planning. On a post-operative CT scan with 3D reconstruction, the distance between the screw tip and the posterior cortex was measured. A one-sample Wilcoxon test was used to compare the distance from the tip of the screw to an acceptable positioning of ±2 mm from the posterior cortex. In the group without planning, screw 1 tended to differ from the acceptable positioning: mean 3.44 mm ± 3.13, med 2.9 mm, q1; q3 [0.6; 4.75] p = 0.1118, and screw 2 differed significantly from the acceptable position: mean 4.83 mm ± 4.11, med 3.7 mm, q1; q3 [1.7; 5.45] p = 0.0045. In the group with planning, position of

  14. A biomechanical study of two different pedicle screw methods for fixation in osteoporotic and nonosteoporotic vertebrae.

    Higashino, Kosaku; Kim, Jin Hwan; Horton, William C; Hutton, William C


    In reconstruction of the osteoporotic spine, patients often show poor outcome because of pedicle screw failure. This study used osteoporotic and nonosteoporotic vertebrae to determine the difference in fixation strength between pedicle screws inserted straight forward and pedicle screws inserted in an upward trajectory toward the superior end plate (i.e., end-plate screws). There is some evidence to suggest that end-plate screws have a strength advantage. The particular focus was on osteoporotic vertebrae. Thirty-three vertebrae (T10-L2) were harvested. The bone mineral density (BMD) was measured: 15 vertebrae were greater than 0.8 g/cm(2) and designated as nonosteoporotic (average BMD 1.146 ± 0.186 g/cm(2)) and 18 vertebrae were designated as osteoporotic (average BMD 0.643 ± 0.088 g/cm(2)). On one pedicle the screw was inserted straight forward and on the other pedicle the screw was inserted as an end-plate screw. The torque of insertion was measured (Proto 6106 torque screwdriver). Using an MTS Mini Bionix, two types of mechanical testing were carried out on each pedicle: (a) cephalocaudad toggling was first carried out to simulate some physiological type loading: 500 cycles at 0.3 Hz, at ±50 N; and (b) then each pedicle screw was pulled out at a displacement rate of 12.5 cm/min.There was no difference in pullout force between the pedicle screws inserted straight forward and the pedicle screws inserted as end-plate screws. This result applies whether the vertebrae were osteoporotic or nonosteoporotic. For both the straight-forward screws and the end-plate screws, a statistically significant correlation was observed between torque of insertion and pullout force. The results of this experiment indicate that pedicle screws inserted as end-plate screws do not provide a strength advantage over pedicle screws inserted straight forward, whether the vertebrae are osteoporotic or not.

  15. Pediatric lumbar pedicle screw placement using navigation templates: A cadaveric study

    Xing Wang


    Full Text Available Background: Pedicle screw technique is commonly used treatment of adult spinal trauma, tumor, degeneration. The application of pedicle screws is very challenging in children because children have a fast growing spine and spinal pedicle morphology of children and adult has large difference. 3 D reconstruction individual navigation templates improve the success rate of pediatric pedicle screw system. This study is aimed to provide a precise method for lumbar spine pedicle screw placement in children using computer-aided design and rapid prototyping technology. Materials and Methods: Computed tomography (CT scans of cadaver specimens of 4 children were obtained, and the raw data were reconstructed using three-dimensional reconstruction software. Pedicle screws were placed using the conventional method or by using individually designed navigation templates based on the principles of reverse engineering and rapid prototyping technology. Results: We evaluated the accuracy of the pedicle screws placed using the two methods by CT scan. Ten navigation templates were designed for placement of 20 lumbar pedicle screws in the navigation group, and CT scan confirmed that all the screws were placed accurately in the corresponding pedicle. Conversely, of the 20 lumbar pedicle screws placed using the conventional method, 3 screws perforated the pedicle. The findings showed that lumbar pedicle screw placement was successful using navigation templates in children. Conclusions: This technique is simple, easy to master, and allows personalized screw placement, thus providing a new and feasible method for lumbar pedicle screw placement in children.

  16. Interfragmentary compression forces of scaphoid screws in a sawbone cylinder model.

    Hausmann, J T; Mayr, W; Unger, E; Benesch, T; Vécsei, V; Gäbler, C


    Various screws have been developed to stabilise fractures of the scaphoid. Commonly used are the Herbert, the HBS, the 3-mm AO and the Acutrak screws. Not long ago a new screw, the Twin Fix, was introduced. This is cannulated and similar in shape and appearance to the classical Herbert screw. In our test series we compared the maximum achievable compression forces of the Twin Fix screw with that of three other screws (AO, HBS and Acutrak screws). To avoid the variations of density, stiffness and rigidity in natural bone, a polyurethane sawbone-based test setup was used. The test series included 10 screws of each type. The compression force was measured using a special strain gauge. The mean compression force was significantly higher for the Twin Fix screw (8+/-1N) and the Acutrak screw (7.6+/-0.4/0.6N) in relation to the AO screw (6.8+/-1.0/1.4N) and HBS screw (2+/-1N). We found the Twin Fix and Acutrak screws to be promising in the treatment of scaphoid fractures.

  17. Ku Band Rotary Joint Design for SNG Vehicles

    H. Torpi


    Full Text Available A wideband I-type rectangular waveguide rotary joint (RJ is designed, simulated and built. It has an excellent performance over the whole Ku Band (10.7-14.5 GHz where the return loss is less than -23 dB at its highest and the insertion loss is below 0.4 dB. The rotary joint is specifically designed for satellite news gathering (SNG vehicles providing elevation and azimuthal movement to the antenna and matching polarization when it is needed at the feed. It can also be used in other high power microwave applications,where rotation ability of the antenna is a must during the transmission such as radars.

  18. Incidence of instrument separation using LightSpeed rotary instruments.

    Knowles, Kenneth I; Hammond, Nathan B; Biggs, Stephen G; Ibarrola, Jose L


    The use of nickel-titanium rotary instrument systems has gained popularity over the past 10 years. One of these instrument systems is the LightSpeed (LightSpeed Technology, Inc, San Antonio, TX). One drawback for all nickel-titanium rotary instruments is the incidence of instrument separation. The purpose of this study was to evaluate the incidence of nonretrievable instrument separation using the LightSpeed system in a clinical setting. A total of 3543 canals were treated over a 24 month period and during that time, 46 LightSpeed instruments were separated and found to be nonretrievable, resulting in a separation rate of 1.30%. This rate was lower than previous reported studies.


    K. G. Mohammed


    Full Text Available The aim of this research is to design a new ac rotary converter machine to convert the ac single phase voltage to six-phase voltages by using multi stages energy conversion machine. The rotary converter is composed from two main stages and is combined into one frame. These two stages are formed from three main electromagnetic components. The first component represents the input stage that enables the energy from single phase to enter and transformed by the second and third components electro-magnetically to produce six-phase voltages which at the output stage. The programs are created using MATLAB in order to calculate the required dimensions of the converter machine and its parameters for magnetic and electrical circuits.

  20. Dry coal fly ash cleaning using rotary triboelectrostatic separator

    TAO Daniel; FAN Mao-ming; JIANG Xin-kai


    More than 80 million metric tons of fly ash is produced annually in the U.S. As coal combustion by-product. Coal fly ash can be converted to value-added products if unburned carbon is reduced to less than 2.5%. However, most of fly ash is currently landfilled as waste due to lack of efficient purification technologies to separate unburned carbon from fly ash. A rotary triboelectrostatic separator has been developed and patented recently at the University of Kentucky with unique features. Several fly ash samples have been used to understand the effects of major process parameters on the separation performance. The results show that compared to existing triboelectrostatic separators, the rotary triboelectrostatic separator has significant advantages in particle charging efficiency, solids throughput, separation efficiency, applicable particle size range.

  1. Design and analysis of a rotary motion controller

    Julio Cesar Caye


    Full Text Available This paper presents the design of a rotary motion controller based on the peritrochoid geometry of the rotary (Wankle engine. It uses an orifice limited flow of incompressible fluid between the chambers of the Wankle-type geometry to control the rotation of the rotor. The paper develops the theory of operation and then implements the design as a Matlab model to simulate the motion control under various conditions. It is found that the time to reach stabilised motion is determined by the orifice size and fluid density. When stabilised motion is achieved, the motion dependence on material and geometry factors is determined by the orifice flow equation. The angular velocity is also found to have a square root dependence on the applied torque when in the stabilised regime.


    WU Jinjun; HAI Jingtao; SHI Jianzhong; LI Xuesong; YANG Qing; WANG Shangyong


    A direct injection low compression ratios diesel rotary engine is designed and studied to find the appropriate application of the electronic controlled high pressure common rail injection system. Current development focuses on the applied fuel injection and ignition strategies, especially concerning the combustion configurations of injectors, ignition source, and combustion chamber. The prototype engine, equipped with Bosch common rail system and high performance electronic control unit (ECU), is designed correspondingly. Studies show that the integration of a common rail injection system and the main and pilot duel injectors configurations, assisted with glow plug ignition device and flexible ECU, represents a promising approach to improve the potential of the low compression ratios diesel rotary engine. Currently the engine can run at 6 kr · min-1 steadily and the power is about 68 kW/(4 kr · min-1).

  3. Development and testing of a rotary solar engine. Final report

    Kanaly, D. B.


    A rotary solar engine has been constructed and tested. By sealing Freon (having the environmentally safe composition rather than the conventionally used harmful composition) in its bellows instead of air, sufficiently consistent operation can be achieved to serve the purely mechanical rotary light-load or no-load markets. Although its power efficiency is not sufficient to make it competitive as a prime power generator, even for power outputs as low as a few ounce inches per minute, it simplicity and reliability make it an attractive self-powered source of mechanical control power for critical slow speed actuators. Its simplicity and low cost make it particularly attractive for the small (less than 10 in/sup 3/) display markets. Other markets may now be identified, now that its strength/limitations are known.

  4. A Diagnostic System for Speed-Varying Motor Rotary Faults

    Chwan-Lu Tseng


    Full Text Available This study proposed an intelligent rotary fault diagnostic system for motors. A sensorless rotational speed detection method and an improved dynamic structural neural network are used. Moreover, to increase the convergence speed of training, a terminal attractor method and a hybrid discriminant analysis are also adopted. The proposed method can be employed to detect the rotary frequencies of motors with varying speeds and can enhance the discrimination of motor faults. To conduct the experiments, this study used wireless sensor nodes to transmit vibration data and employed MATLAB to write codes for functional modules, including the signal processing, sensorless rotational speed estimation, neural network, and stochastic process control chart. Additionally, Visual Basic software was used to create an integrated human-machine interface. The experimental results regarding the test of equipment faults indicated that the proposed novel diagnostic system can effectively estimate rotational speeds and provide superior ability of motor fault discrimination with fast training convergence.

  5. Anatomic considerations of costotransverse screw placement in the thoracic spine.

    Xu, R; Ebraheim, N A; Ou, Y; Skie, M; Yeasting, R A


    Numerous techniques have been reported to restore spinal stability and to correct spinal deformities, including rods with wires/hooks, and rods or plates with pedicular screws. It was thought that posterior fixation of the thoracic spine through the costotransverse joint may be another alternative. Nine cadavers were obtained for study of screw fixation of the costotransverse joint for posterior thoracic instrumentation. The entrance point for screw insertion was designed to be at the posterior center of the clubbed extremity of the transverse process. From this point, a 3-mm drill bit was used to create the screw path penetrating the costotransverse joint and the ventral cortex of the rib. Under direct visualization of the costotransverse joint, the drill bit was directed parallel to the sagittal plane and toward the upper portion of the rib. Measurements included the screw path length and sagittal angulation. Also, the distance between the superior borders of the transverse process and the tubercle of the rib and the anatomic relationship of the drill bit exit to the intercostal vessels and nerves were evaluated. The maximum length of the screw path was found at T1 (19.7 mm), whereas the minimum length was noted at T4-T5 (13.9 mm). This value decreased gradually from T1 to T4-T5, and slightly increased to T10. The larger sagittal angles of the screw path were found at the levels of T1-T4 (78-86 degrees ), whereas the smaller were noted at the levels below T5 (53-61 degrees ). The mean distance between the superior borders of the transverse process and the tubercle of the rib was smaller at T1-T5 (0.2-0.4 mm), and significantly increased to T8 (5. 1 mm), and then slightly decreased to T10. The variation of this parameter was remarkable. All of the exit points for the drill bit were located in the upper half of the rib, and away from the intercostal vessels. The ideal screw orientation is parallel to the sagittal plane, and angled 80-90 degrees relative to the

  6. The Study of Vibration Processes in Oil Flooded Screw Compressors

    I. V. Filippov


    Full Text Available Vibration processes that accompany most of machines and mechanisms are of interest to the researcher, as a source of information about the technical condition and the nature of the business processes flow. Vibration-based diagnostics of oil flooded screw compressors allows us to estimate the deviation of their operation from the main mode in accordance with changing the settings of vibration processes.The oil flooded screw compressor transition from the main mode of operation to the abnormal one is accompanied by complex gas-dynamic phenomena i.e. the initial gaps and their decays. This leads to changes in the nature of vibration processes, prompting suggestions that there is a relationship to a change of vibration parameters and mode of compressor operation.Studies were conducted by combined method using an analytical calculation of the decay parameters of the initial discontinuity and an experimental one based on the measurement of acceleration on the body of the real oil flooded screw compressor. A virtually adequate reaction of the decay parameters of the initial gap and the peak values of vibration acceleration to the change of operation mode of oil flooded screw compressor has been received. The peak value of the vibration acceleration was selected by the method of Gating being time-coinciding with the beginning discharge phase of the oil flooded screw compressor, and therefore, with the decay time of the initial discontinuity.This indicates a large degree of hypothesis likelihood on an existing initial break in oil flooded screw compressor when operating in abnormal conditions. This work contains the study results of vibration processes and their relationship to the operating mode of the oil flooded screw compressor, which distinguish it from the other works studied vibration processes in reciprocating compressors. The vibration parameters control of operating oil flooded screw compressor allows us to create an automatic capacity control

  7. Numerical and experimental study of an Archimedean Screw Generator

    Dellinger, G.; Garambois, P.-A.; Dufresne, M.; Terfous, A.; Vazquez, J.; Ghenaim, A.


    Finding new, safe and renewable energy is becoming more and more of a priority with global warming. One solution that is gaining popularity is the Archimedean Screw Generator (ASG). This kind of hydroelectric plant allows transforming potential energy of a fluid into mechanical energy and is convenient for low-head hydraulic sites. As it is a new and growing technology, there are few references dealing with their design and performance optimization. The present contribution proposes to investigate experimentally and numerically the ASG performances. The experimental study is performed for various flow conditions and a laboratory scale screw device installed at the fluid mechanics laboratory of the INSA of Strasbourg. The first results show that the screw efficiencies are higher than 80% for various hydraulic conditions. In order to study the structure of 3D turbulent flows and energy losses in a screw, the 3D Navier Stokes equations are solved with the k-w SST turbulence model. The exact geometry of the laboratory-scale screw was used in these simulations. Interestingly, the modeled values of efficiency are in fairly good agreement with experimental results while any friction coefficient is involved.

  8. Treatment of scaphoid waist fractures with the HCS screw

    Gehrmann, Sebastian V.


    Full Text Available The aim of the study was to evaluate the clinical results of the Headless Compression Screw (HCS, Synthes when used for treatment of acute scaphoid waist fractures. The new screw design generates interfragmentary compression with use of a compression sleeve. Twenty-one patients were treated for acute scaphoid waist fractures type B2 with HCS screws. The average time to the final follow-up examination was 12.8 months. All 21 fractures united after a mean time of 7.2 weeks. The mean DASH score was 7.1. The average motion of the wrist in extension was 61°, flexion was 46°, radial abduction reached 25° and the ulnar abduction was 31°. The maximally achieved grip strength was 86% compared to the uninjured side. Treatment of type B2 scaphoid fractures with the Headless Compression Screw showed good functional and radiographic results. The results are similar to those identified using other screw fixation systems.

  9. Studies on positive conveying in helically channeled single screw extruders

    L. Pan


    Full Text Available A solids conveying theory called double-flight driving theory was proposed for helically channeled single screw extruders. In the extruder, screw channel rotates against static barrel channel, which behaves as cooperative embedded twin-screws for the positive conveying. They turn as two parallel arc plates, between which an arc-plate solid-plug was assumed. By analyzing the forces on the solid-plug in the barrel channel and screw channel, the boundary conditions when the solid-plug is waived of being cut off on barrel wall, were found to have the capacity of the positive conveying. Experimental data were obtained using a specially designed extruder with a helically channeled barrel in the feeding zone and a pressure-adjustable die. The effects of the barrel channel geometry and friction coefficients on the conveying mechanism were presented and compared with the experimental results. The simulations showed that the positive conveying could be achieved after optimizing extruder designs. Compared with the traditional design with the friction-drag conveying, the throughput is higher while screw torque and energy consumption are decreased. Besides, the design criteria of the barrel channel were also discussed.

  10. Screw dislocations in GaN grown by different methods

    Liliental-Weber, Z.; Zakharov, D.; Jasinski, J.; O' Keefe, M.A.; Morkoc, H.


    A study of screw dislocations in Hydride-Vapor-Phase-Epitaxy (HVPE) template and Molecular-Beam-Epitaxy (MBE) over-layers was performed using Transmission Electron Microscopy (TEM) in plan-view and in cross-section. It was observed that screw dislocations in the HVPE layers were decorated by small voids arranged along the screw axis. However, no voids were observed along screw dislocations in MBE overlayers. This was true both for MBE samples grown under Ga-lean and Ga-rich conditions. Dislocation core structures have been studied in these samples in the plan-view configuration. These experiments were supported by image simulation using the most recent models. A direct reconstruction of the phase and amplitude of the scattered electron wave from a focal series of high-resolution images was applied. It was shown that the core structures of screw dislocations in the studied materials were filled. The filed dislocation cores in an MBE samples were stoichiometric. However, in HVPE materials, single atomic columns show substantial differences in intensities and might indicate the possibility of higher Ga concentration in the core than in the matrix. A much lower intensity of the atomic column at the tip of the void was observed. This might suggest presence of lighter elements, such as oxygen, responsible for their formation.

  11. Screw theoretic view on dynamics of spatially compliant beam

    Xi-lun DING; J.M.SELIG


    Beams with spatial compliance can be deformed as bending in a plane,twisting,and extending.In terms of the screw theory on rigid body motions,the concept of"deflection screw"is introduced,a spatial compliant beam theory via the deflection screw is proposed,and the spatial compliance of such a beam system is presented and analysed based on the material theory and fundamental kinematic assumptions.To study the dynamics of the spatially compliant beam,the potential energy and the kinetic energy of the beam are discussed by using the screw theory to obtain the Lagrangian.The Rayleigh-Ritz method is used to compute the vibrational frequencies based on discussions of boundary conditions and shape functions.The eigenfrequencies of the beam with spatial compliance are compared with those of individual deformation cases,pure bending,extension,or torsion.Finally,dynamics of a robot with two spatial compliant links and perpendicular joints is studied using the spatial compliant beam theory.Coupling between the joint rigid body motions and the deformations of spatial compliant links can easily be found in dynamic simulation.The study shows the effectiveness of using the screw theory to deal with the problems of dynamic modeling and analysis of mechanisms with spatially compliant links.

  12. Mathematical modeling of a rotary hearth coke calciner

    Hilde C. Meisingset


    Full Text Available A mathematical model of a rotary hearth coke calciner is developed. The model is based on first principles including the most important dynamic phenomena. The model is a thermodynamic model involving heat and mass transfer and chemical reactions. Fundamental mass and energy balance equations for the coke phase, the gas phase and the lining are formulated. For the gas phase, a stationary model is used. The equations are solved numerically, and simulated temperature profiles are shown in this paper.

  13. Modeling of Pulverized Coal Combustion in Cement Rotary Kiln


    In this paper, based on analysis of the chemical and physical processes of clinker formation, a heat flux function was introduced to take account of the thermal effect of clinker formation. Combining the models of gas-solid flow, heat and mass transfer, and pulverized coal combustion, a set of mathematical models for a full-scale cement rotary kiln were established. In terms of commercial CFD code (FLUENT), the distributions of gas velocity, gas temperature, and gas components in a cement rot...

  14. Piezoelectric Versus Conventional Rotary Techniques for Impacted Third Molar Extraction

    Jiang, Qian; Qiu, Yating; Yang, Chi; Yang, Jingyun; Chen, Minjie; Zhang, Zhiyuan


    Abstract Impacted third molars are frequently encountered in clinical work. Surgical removal of impacted third molars is often required to prevent clinical symptoms. Traditional rotary cutting instruments are potentially injurious, and piezosurgery, as a new osteotomy technique, has been introduced in oral and maxillofacial surgery. No consistent conclusion has been reached regarding whether this new technique is associated with fewer or less severe postoperative sequelae after third molar extraction. The aim of this study was to compare piezosurgery with rotary osteotomy techniques, with regard to surgery time and the severity of postoperative sequelae, including pain, swelling, and trismus. We conducted a systematic literature search in the Cochrane Library, PubMed, Embase, and Google Scholar. The eligibility criteria of this study included the following: the patients were clearly diagnosed as having impacted mandibular third molars; the patients underwent piezosurgery osteotomy, and in the control group rotary osteotomy techniques, for removing impacted third molars; the outcomes of interest include surgery time, trismus, swelling or pain; the studies are randomized controlled trials. We used random-effects models to calculate the difference in the outcomes, and the corresponding 95% confidence interval. We calculated the weighted mean difference if the trials used the same measurement, and a standardized mean difference if otherwise. A total of seven studies met the eligibility criteria and were included in our analysis. Compared with rotary osteotomy, patients undergoing piezosurgery experienced longer surgery time (mean difference 4.13 minutes, 95% confidence interval 2.75–5.52, P trismus in the piezosurgery groups. The number of included randomized controlled trials and the sample size of each trial were relatively small, double blinding was not possible, and cost analysis was unavailable due to a lack of data. Our meta-analysis indicates that although

  15. A Short Study of Large Rotary Forged Cylinders


    Bottom) 7 Microstructure at mid-wall of reheat treated rotary 25 forged cylinders - Martensite- Bainite 8 Martensitic microstructure of (a) normalized...also was unsatisfactory (Table 2). The microstructure at the mid-wall of both the top and bottom showed evidence of ferrite and bainite (Figs. 1 and...austenitized, and of bainite , showing that the material transformed to austenite had been in- adequately quenched, since martensite is the desired product

  16. Plastic forming behavior of axisymmetric bimetal products with rotary swaging

    Song Tao; Zhao Shengdun; Yan Guanhai; Liu Hongbao


    In this paper,an elasto-viscoplastic three-dimension (3D) finite element model is developed to simulate the processing of bimetal tube with rotary swaging.Through simulation,the effects of high-frequency pulse stroking on the distribution and histories of stress,stain and loading are clarified.The stress in inner tube is compressive and higher than the minimum bonding force.Meanwhile,the stiffness of inner tube impacts outer tube extension in length.

  17. Rotary Ultrasonic Machining of Poly-Crystalline Cubic Boron Nitride


    Poly-crystalline cubic boron nitride (PCBN) is one of the hardest material. Generally, so hard materials could not be machined by conventional machining methods. Therefore, for this purpose, advanced machining methods have been designed. Rotary ultrasonic machining (RUM) is included among them. RUM is based on abrasive removing mechanism of ultrasonic vibrating diamond particles, which are bonded on active part of rotating tool. It is suitable especially for machining hard and brittle materia...

  18. Expanding Your Horizon 2015

    Kaltenhauser, Kristin


    Expanding your horizons is a bi-annual “Science Day” for girls aged 11 to 14, held at the University of Geneva on 14 November. The girls had the opportunity to take part in hands-on workshops held by local professional women in the field of science, mathematics, engineering and technology. For the fourth time, CERN was part of this event, offering three workshops as well as a booth at the Discovery Fair, including Higgnite, an interactive visualization of the Higgs Field.

  19. The expanding universe

    Lew, Kristi


    People have always been fascinated with the stars above and the universe that contains them. Over the years, astronomers have developed numerous theories to explain how the universe began, how it works, and what its ultimate fate will be. But all of the scientists' questions are far from answered. The Expanding Universe goes beyond the creation of the universe to explain how scientists think the universe works, grows, and changes, including what great thinkers Isaac Newton and Albert Einstein had to say about its fate. Readers will also learn about how researchers are slowly shedding light on

  20. Reciprocating Expander for an Exhaust Heat Recovery Rankine Cycle for a Passenger Car Application

    Osoko Shonda


    Full Text Available Nowadays, on average, two thirds of the fuel energy consumed by an engine is wasted through the exhaust gases and the cooling liquid. The recovery of this energy would enable a substantial reduction in fuel consumption. One solution is to integrate a heat recovery system based on a steam Rankine cycle. The key component in such a system is the expander, which has a strong impact on the system’s performance. A survey of different expander technologies leads us to select the reciprocating expander as the most promising one for an automotive application. This paper therefore proposes a steady-state semi-empirical model of the expander device developed under the Engineering Equation Solver (EES environment. The ambient and mechanical losses as well as internal leakage were taken into account by the model. By exploiting the expander manufacturer’s data, all the parameters of the expander model were identified. The model computes the mass flow rate, the power output delivered and the exhaust enthalpy of the steam. The maximum deviation between predictions and measurement data is 4.7%. A performance study of the expander is carried out and shows that the isentropic efficiency is quite high and increases with the expander rotary speed. The mechanical efficiency depends on mechanical losses which are quite high, approximately 90%. The volumetric efficiency was also evaluated.

  1. Behavioral changes in preschoolers treated with/without rotary instruments

    Maru, Viral Pravin; Kumar, Amit; Badiyani, Bhumika Kamal; Sharma, Anant Raghav; Sharma, Jitendra; Dobariya, Chintan Vinodbhai


    Background: Behavioral dentistry is an interdisciplinary science which needs to be learned, practiced, and reinforced in order to provide quality dental care in children. Aim: To assess the anxiety experienced during dental treatment in preschool children with/without rotary instruments using behavioral scale. Study and Design: Sixty pediatric patients of preschool age with bilateral occlusal carious lesions extending into dentin were selected for the study. Carious lesions were removed using conventional rotary instruments on one side and Papacarie – chemomechanical caries removal of approach on contra lateral side. Both cavities were restored with glass ionomer cement (Fuji IX). Anxiety scores were determined using ‘Modified Child Dental Anxiety Scale’ (Wong et al, 1998) during the various clinical stages of the treatment course. Results: Children experienced relaxed behavior when subjected to Papacarie method of caries removal compared to conventional method using rotary instruments. Conclusion: This study helped us to provide behavioral measures and introduce children to dentistry in a nonthreatening setting. PMID:25254189

  2. Rotation of artificial rotor axles in rotary molecular motors.

    Baba, Mihori; Iwamoto, Kousuke; Iino, Ryota; Ueno, Hiroshi; Hara, Mayu; Nakanishi, Atsuko; Kishikawa, Jun-Ichi; Noji, Hiroyuki; Yokoyama, Ken


    F1- and V1-ATPase are rotary molecular motors that convert chemical energy released upon ATP hydrolysis into torque to rotate a central rotor axle against the surrounding catalytic stator cylinder with high efficiency. How conformational change occurring in the stator is coupled to the rotary motion of the axle is the key unknown in the mechanism of rotary motors. Here, we generated chimeric motor proteins by inserting an exogenous rod protein, FliJ, into the stator ring of F1 or of V1 and tested the rotation properties of these chimeric motors. Both motors showed unidirectional and continuous rotation, despite no obvious homology in amino acid sequence between FliJ and the intrinsic rotor subunit of F1 or V1 These results showed that any residue-specific interactions between the stator and rotor are not a prerequisite for unidirectional rotation of both F1 and V1 The torque of chimeric motors estimated from viscous friction of the rotation probe against medium revealed that whereas the F1-FliJ chimera generates only 10% of WT F1, the V1-FliJ chimera generates torque comparable to that of V1 with the native axle protein that is structurally more similar to FliJ than the native rotor of F1 This suggests that the gross structural mismatch hinders smooth rotation of FliJ accompanied with the stator ring of F1.

  3. Multi-Fuel Rotary Engine for General Aviation Aircraft

    Jones, C.; Ellis, D. R.; Meng, P. R.


    Design studies, conducted for NASA, of Advanced Multi-fuel General Aviation and Commuter Aircraft Rotary Stratified Charge Engines are summarized. Conceptual design studies of an advanced engine sized to provide 186/250 shaft KW/HP under cruise conditions at 7620/25,000 m/ft. altitude were performed. Relevant engine development background covering both prior and recent engine test results of the direct injected unthrottled rotary engine technology, including the capability to interchangeably operate on gasoline, diesel fuel, kerosene, or aviation jet fuel, are presented and related to growth predictions. Aircraft studies, using these resultant growth engines, define anticipated system effects of the performance and power density improvements for both single engine and twin engine airplanes. The calculated results indicate superior system performance and 30 to 35% fuel economy improvement for the Rotary-engine airplanes as compared to equivalent airframe concept designs with current baseline engines. The research and technology activities required to attain the projected engine performance levels are also discussed.

  4. Fragmentation of Newtonian and viscoelastic liquids during rotary atomization

    Keshavarz, Bavand; Moore, John; Houze, Eric; Koerner, Michael; McKinley, Gareth; MIT Collaboration; Axalta Coating Systems Collaboration


    Animals drying their wet fur by rapidly shaking their body and rotary atomization in paint coating are just a few examples in which centripetal acceleration is used to disintegrate liquid films into smaller fragments. Narrower size distributions and well-defined geometrical fluid pathlines (similar to the involute of a circle) are the main advantages of this type of atomization as compared to air-assisted atomization. Despite these inherent advantages there is a paucity of fundamental knowledge about the roles of fluid rheology in this process. We study the effects of viscosity by performing rotary atomization tests on silicone oils with a wide range of viscosities (1-1000 mPa.s). Viscoelastic effects are also probed by spraying solutions of polyethylene oxide (PEO) dissolved in water at different concentrations. Our results show that understanding the effects of liquid properties on the instabilities that control rotary atomization (primarily Rayleigh-Taylor instability during the ligament formation followed by Rayleigh-Plateau instability during droplet pinch-off) can help us understand the resulting fragment size distributions.

  5. Fatigue behavior of lubricated Ni-Ti endodontic rotary instruments

    A. Brotzu


    Full Text Available The use of Ni-Ti alloys in the practice of endodontic comes from their important properties such as shape memory and superelasticity phenomena, good corrosion resistance and high compatibility with biological tissues. In the last twenty years a great variety of nickel-titanium rotary instruments, with various sections and taper, have been developed and marketed. Although they have many advantages and despite their increasing popularity, a major concern with the use of Ni-Ti rotary instruments is the possibility of unexpected failure in use due to several reasons: novice operator handling, presence manufacturing defects, fatigue etc. Recently, the use of an aqueous gel during experimental tests showed a longer duration of the instruments. The aim of the present work is to contribute to the study of the fracture behavior of these endodontic rotary instruments particularly assessing whether the use of the aqueous lubricant gel can extend their operative life stating its reasons. A finite element model (FEM has been developed to support the experimental results. The results were rather contradictory, also because the Perspex (Poly-methyl methacrylate, PMMA cannot simulate completely the dentin mechanical behavior; however the results highlight some interesting points which are discussed in the paper.

  6. Fluorescence of primary dentine after chemomechanical and conventional rotary excavation.

    Corrêa, F N P; Rocha, R O; Soares, F Z M; Rodrigues-Filho, L E; Rodrigues, C R M


    This was to compare fluorescence values of dentine remaining after caries removal using chemomechanical systems and conventional rotary methods. In vitro study. 30 extracted primary teeth with proximal carious cavities were divided into three groups according to caries removal method: Carisolv, Papacarie and conventional low speed rotary burs. Carious (initial) and remaining (final) dentine evaluations were assessed by visual-tactile examination and DIAGNOdent. Transversal microhardness (TMH) of remaining dentine was evaluated. Fluorescence and TMH values were submitted to two-way ANOVA and the post hoc Tukey test (alpha = 0.05) and Pearson's linear correlation. Two-way ANOVA revealed that fluorescence values were similar between conventional rotary excavation, Carisolv and Papacarie groups (p = 0.0542). No statistically significant differences (p = 0.1147) were found to TMH values. No correlation was found between fluorescence and TMH values (r = -0.0273). All caries excavation methods resulted in similar remaining dentine fluorescence values. No correlation was found between fluorescence values and TMH of remaining dentine.

  7. Robustness of the rotary catalysis mechanism of F1-ATPase.

    Watanabe, Rikiya; Matsukage, Yuki; Yukawa, Ayako; Tabata, Kazuhito V; Noji, Hiroyuki


    F1-ATPase (F1) is the rotary motor protein fueled by ATP hydrolysis. Previous studies have suggested that three charged residues are indispensable for catalysis of F1 as follows: the P-loop lysine in the phosphate-binding loop, GXXXXGK(T/S); a glutamic acid that activates water molecules for nucleophilic attack on the γ-phosphate of ATP (general base); and an arginine directly contacting the γ-phosphate (arginine finger). These residues are well conserved among P-loop NTPases. In this study, we investigated the role of these charged residues in catalysis and torque generation by analyzing alanine-substituted mutants in the single-molecule rotation assay. Surprisingly, all mutants continuously drove rotary motion, even though the rotational velocity was at least 100,000 times slower than that of wild type. Thus, although these charged residues contribute to highly efficient catalysis, they are not indispensable to chemo-mechanical energy coupling, and the rotary catalysis mechanism of F1 is far more robust than previously thought.

  8. Undergraduates’ opinion after 5-year experience with rotary endodontic instruments

    Flávia Sens Fagundes Tomazinho


    Full Text Available Introduction: Dentistry evolution in the past few years has revolutionized daily practice in some specialties. One of these revolutions has occurred in Endodontics due to the advancement of rotary techniques for root canal preparation and its subsequent incorporation into the teaching of Dentistry undergraduates. Objective: The aim of this study was to report a 5-year experience on the undergraduate laboratorial and clinical use of rotary endodontic preparation at a private university. Material and methods: Data survey was performed by using a questionnaire composed of nine objective questions; the questionnaire was answered by the undergraduates. Results: The results showed a positive acceptance regarding the undergraduate teaching of the rotary technique (94.7%. The following advantages were highlighted: faster root canal preparation (91.6% and reduction of patient’s stress (80.9%. Conclusion: It can be concluded that the experience with the two undergraduate groups was excellent due to the high acceptance level of the new technique by the students.

  9. Virtual Prototyping and Development of Rotary Field Ferrite Phase Shifter

    Meenakshi Aggarwal


    Full Text Available Review of the virtual prototyping and physical development of the rotary field ferrite phase shifter is presented. A description of the basic principle of operation of the rotary field ferrite phase shifter has been given along with the key aspects about the design and virtual prototyping of various parts of the phase shifter viz ferrite rod, yoke, polarisers and matching section using HFSS and 3-D Maxwell softwares. Calibrated simulation performance of the phase shifters is presented and it shows good agreement with physical measurement results. Three prototypes and one hundred production capable phase shifter modules were fabricated, functionally tested and RF characterised. This is an indigenous development of the physical prototypes of rotary field class of ferrite phase shifters of C-band. This class of ferrite phase shifters finds application in phased array radars, such as battery level radar and weapon locating radar, because of its high phase accuracy and high power handling capability.Defence Science Journal, Vol. 66, No. 2, March 2016, pp. 156-161, DOI:

  10. FLIR systems submicro rotary stirling cycle IDCA for imaging systems

    Uri, Bin-Nun


    The advantages of the common Rotary Stirling cycle coolers over the Split Stirling Linear are the overall size, light weight, low cooler input power and high efficiency. The main disadvantage has always been self induced vibration. Self induced vibration is a major consideration in the design of stabilized IR imaging systems/(GIMBALS) due to the effect it has on image quality i.e. Jitter. The "irregular shape" of the Rotary cooling engine attached to the payload and optics is also a problem in terms of the limits it has on optical system size. To address these issues, FLIR Systems Inc in Boston MA, developed a new rotary Stirling cycle cooling engine known as the FLIR Submicro Cooler. The Submicro is now in production and has been applied in a few products especially in FLIR"S smallest GIMBAL which measures 7.0 inch in spherical diameter. In this paper we discuss the improvements made in terms of IDCA implementation in stabilized imaging systems.

  11. Design analysis of rotary turret of poucher machine

    Jigar G. Patel


    Full Text Available This paper present design analysis of rotary turret plate of 5 kg capacity for food product packaging machine. The turret plate has been designed considering two different criteria, first one is inertia force approach with only self-weight of turret plate and second is with mass of pouches. A 3-dimenssional CAD model of rotary turret assembly has been prepared in using solid modelling packages CRE-O. The finite element analysis (FEA of turret plate has been carried out using analysis software ANSYS 15.0. Consideration of inertia force is one of the criteria to analyze the performance and behaviour of component in working condition. The rotational velocity is applied at the central axis of turret and friction less support is applied on inner surface, where shaft is being attached. Also, pressure is applied on the same surface to incorporate the shrink fit condition of the assembly of turret plate with shaft. The boundary conditions as fixed support have been considered at the different sixteen faces, where bolts have been attached. The obtained simulation results for induced stress, deformation and strain depict that the modified design of rotary turret plate is well within the allowable stress limits of considered material. And, further optimization can be performed for topological and strength based more efficient design of turret plate.

  12. Numerical Analysis on Combustion Characteristic of Leaf Spring Rotary Engine

    Yan Zhang


    Full Text Available The purpose of this paper is to investigate combustion characteristics for rotary engine via numerical studies. A 3D numerical model was developed to study the influence of several operative parameters on combustion characteristics. A novel rotary engine called, “Leaf Spring Rotary Engine”, was used to illustrate the structure and principle of the engine. The aims are to (1 improve the understanding of combustion process, and (2 quantify the influence of rotational speed, excess air ratio, initial pressure and temperature on combustion characteristics. The chamber space changed with crankshaft rotation. Due to the complexity of chamber volume, an equivalent modeling method was presented to simulate the chamber space variation. The numerical simulations were performed by solving the incompressible, multiphase Unsteady Reynolds-Averaged Navier–Stokes Equations via the commercial code FLUENT using a transport equation-based combustion model; a realizable  turbulence model and finite-rate/eddy-dissipation model were used to account for the effect of local factors on the combustion characteristics.

  13. Design of an Improved Type Rotary Inductive Coupling Structure for Rotatable Contactless Power Transfer System

    Lee Jia-You


    Full Text Available This paper is aimed at analyzing the rotary inductive coupling structure of contactless rotary transformer. The main feature of the proposed rotatable contactless power transfer system is which winding is coaxial-interlayered for improving the magnetic coupling capability. There is no ferrite core used in the secondary-side of the rotary inductive coupling structure, this helps to ease the exerted force that is stress by the secondary-side on spindle. In order to verify the feasibility of the proposed contactless power transfer system for rotary applications, an inductive powered rotary machinery and the control system have been integrated. The experimental results show that the maximum power transfer efficiency of the proposed rotary inductive coupling structure is about 94.8%. The maximum output power received in the load end is 1030 W with transmission efficiency of 88%.

  14. Screw Performance Degradation Assessment Based on Quantum Genetic Algorithm and Dynamic Fuzzy Neural Network

    Xiaochen Zhang


    Full Text Available To evaluate the performance of ball screw, screw performance degradation assessment technology based on quantum genetic algorithm (QGA and dynamic fuzzy neural network (DFNN is studied. The ball screw of the CINCINNATIV5-3000 machining center is treated as the study object. Two Kistler 8704B100M1 accelerometers and a Kistler 8765A250M5 three-way accelerometer are installed to monitor the degradation trend of screw performance. First, screw vibration signal features are extracted both in time domain and frequency domain. Then the feature vectors can be obtained by principal component analysis (PCA. Second, the initialization parameters of the DFNN are optimized by means of QGA. Finally, the feature vectors are inputted to DFNN for training and then get the screw performance degradation model. The experiment results show that the screw performance degradation model could effectively evaluate the performance of NC machine screw.

  15. Influence of bacterial colonization of the healing screws on peri-implant tissue

    Simonetta D'Ercole


    Conclusion: The healing screws left in situ for a period of 90 days caused a peri-implant inflammation and the presence of periodontal pathogenic bacteria in the peri-implant sulcus, due to the plaque accumulation on screw surfaces.

  16. On the Effect of Thread Turn Profile Angle of the Planetary Roller-Screw Mechanism Parts on Their Basic Parameters

    D. S. Blinov


    Full Text Available One of the most important trends in mechanical engineering development is the constant improvement of load capacity of machines, mechanisms, units and parts without increasing their overall dimensions and weight. This is also true for today’s most prospective planetary rollerscrew mechanisms (PRSM converting motion from rotary to linear type. The problem of PRSM load capacity improvement deserves more attention, because these mechanisms have very high performance characteristics, which leads to problems in the choice of support devices for these mechanisms.However, for many mechanical engineering industries it is important to decrease the PRSMs weight and dimensions, or to improve their reliability and durability. This has led to finding the reserves for improving the PRSM load capacity by decreasing the thread turn profile angle, α, of PRSM threaded parts, as compared to α = 90° in traditional mechanisms. When PRSM calculation methods were developed, it was decided to use α = 90° for transforming the mechanism parts into a physical model and a design pattern. It allowed us to reduce the PRSM designing to well-known roller bearing designing based on very extensive experimental data.Proposed PRSM designs do not contradict to accepted physical models and design patterns – they just have different basic characteristics of PRSM, i.e. static and dynamic load ratings. Proposed PRSM designs with a thread turn profile angle α=70° on their parts allow to increase the load capacity by 15%, as compared to traditional PRSMs, which have threaded parts with a thread turn profile angle α = 90°. There are two factors, which can improve the PRSM load capacity. The first one is the decrease of normal force between mating thread turns of a screw and a roller with the same operational axial force. The second one is the increase of the radius of the shaped profile of a roller thread turn resulting in the expansion of the contact area pattern between the

  17. Instantaneous screws of weight-bearing knee: what can the screws tell us about the knee motion.

    Wolf, Alon


    There are several ways to represent a given object's motion in a 3D space having 6DOF i.e., three translations and three rotations. Some of the methods that are used are mathematical and do not provide any geometrical insight into the nature of the motion. Screw theory is a mathematical, while at the same time, geometrical method in which the 6DOF motion of an object can be represented. We describe the 6DOF motion of a weight-bearing knee by its screw parameters, that are extracted from 3D Optical Reflective motion capture data. The screw parameters which describe the transformation of the shank with respect to the thigh in each two successive frames, is represented as the instantaneous screw axis of the motion given in its Plücker line coordinate, along with its corresponding pitch and intensity values. Moreover, the Striction curve associated with the motion provides geometrical insight into the nature of the motion and its repeatability. We describe the theoretical background and demonstrate what the screw can tell us about the motion of healthy subjects' knee.

  18. Augmentation of Pedicle Screw Fixation with Calcium Phosphate Cement

    YANG Shu-hua; FU De-hao; LI Jin; XU Wei-hua; YANG Cao; YE Zhe-wei; ZUO Xiao-yan


    To determine whether a biodegradable calcium phosphate cement(CPC) provides significant augmentation of pedicle screw fixation or not,an in vitro biomechanical study was carried out to evaluate the biomechanical effect of CPC in the restoration and augmentation of pedicle screw fixation.Axial pullout test and cyclic bending resistance test were employed in the experiment,and polymethylmethacrylate (PMMA) was chosen as control.The results demonstrate that the pullout strengths following CPC restoration and augmentation are 74% greater on an average than those of the control group,but less than those of PMMA restoration group and augmentation group respectively (increased by 126% versus control).In cyclic bending resistance test,the CPC augmented screws are found to withstand a greater number of cycles or greater loading with less displacement before loosening,but the augmentation effect of PMMA is greater than that of CPC.

  19. [Midcarpal fusion using break-away compression screw].

    Maire, N; Facca, S; Gouzou, S; Liverneaux, P


    Indication of midcarpal fusion is SNAC or SLAC wrist grade 3. The main complication of circular plate (most common technique) is non-union. In this context, the purpose of our work was to propose the use of break-away compression screws to decrease the rate of non-union. Our series included ten patients. The fusion was fixed using two break-away compression screws (2mm diameter). No bone graft was used. As assessment, subjective (pain, Quick-DASH) and objective (strength, mobility) criteria were reviewed at follow-up. All the criteria were significantly improved after operation except mobility. Among the complications, we noticed one delayed bone-healing with a good outcome and a radiological consolidation. Midcarpal fusion by dorsal approach using break-away compression screws appears to us a technique of interest, not requiring a bone graft, with good cost effectiveness.

  20. Error Analysis of Robotic Assembly System Based on Screw Theory

    韩卫军; 费燕琼; 赵锡芳


    Assembly errors have great influence on assembly quality in robotic assembly systems. Error analysis is directed to the propagations and accumula-tions of various errors and their effect on assembly success.Using the screw coordinates, assembly errors are represented as "error twist", the extremely compact expression. According to the law of screw composition, relative position and orientation errors of mating parts are computed and the necessary condition of assembly success is concluded. A new simple method for measuring assembly errors is also proposed based on the transformation law of a screw.Because of the compact representation of error, the model presented for error analysis can be applied to various part- mating types and especially useful for error analysis of complexity assembly.

  1. New concept single screw compressors and their manufacture technology

    Feng, Q.; Liu, F.; Chang, L.; Feng, C.; Peng, C.; Xie, J.; van den Broek, M.


    Single screw compressors were generally acknowledged as one of the nearly perfect machines by compressor researchers and manufacturers. However the rapid wear of the star-wheel in a single screw compressor during operation is a key reason why it hasn’t previously joined the main current compressors’ market. After more than ten years of effective work, the authors of this paper have proposed a new concept single screw compressor whose mesh-couple profile is enveloped with multi-column. Also a new design method and manufacture equipment for this kind of compressor have been developed and are described in this paper. A lot of prototype tests and a long period of industrial operations under full loading conditions have shown that the mesh-couple profiles of the new concept single compressors have excellent anti-wearness.

  2. Optically driven Archimedes micro-screws for micropump application.

    Lin, Chih-Lang; Vitrant, Guy; Bouriau, Michel; Casalegno, Roger; Baldeck, Patrice L


    Archimedes micro-screws have been fabricated by three-dimensional two-photon polymerization using a Nd:YAG Q-switched microchip laser at 532nm. Due to their small sizes they can be easily manipulated, and made to rotate using low power optical tweezers. Rotation rates up to 40 Hz are obtained with a laser power of 200 mW, i.e. 0.2 Hz/mW. A photo-driven micropump action in a microfluidic channel is demonstrated with a non-optimized flow rate of 6 pL/min. The optofluidic properties of such type of Archimedes micro-screws are quantitatively described by the conservation of momentum that occurs when the laser photons are reflected on the helical micro-screw surface.

  3. Experimental determination of bone cortex holding power of orthopedic screw

    Bolliger Neto Raul


    Full Text Available Cylindrical specimens of bone measuring 15 mm in diameter were obtained from the lateral cortical layer of 10 pairs of femurs and tibias. A central hole 3.2 mm in diameter was drilled in each specimen. The hole was tapped, and a 4.5 mm cortical bone screw was inserted from the outer surface. The montage was submitted to push-out testing up to a complete strip of the bone threads. The cortical thickness and rupture load were measured, and the shear stress was calculated. The results were grouped according to the bone segment from which the specimen was obtained. The results showed that bone cortex screw holding power is dependent on the bone site. Additionally, the diaphyseal cortical bone tissue is both quantitatively and qualitatively more resistant to screw extraction than the metaphyseal tissue.

  4. Odontoid screw fixation for fresh and remote fractures

    Rao Ganesh


    Full Text Available Fractures of the odontoid process are common, accounting for 10% to 20% of all cervical spine fractures. Odontoid process fractures are classified into three types depending on the location of the fracture line. Various treatment options are available for each of these fracture types and include application of a cervical orthosis, direct anterior screw fixation, and posterior cervical fusion. If a patient requires surgical treatment of an odontoid process fracture, the timing of treatment may affect fusion rates, particularly if direct anterior odontoid screw fixation is selected as the treatment method. For example, type II odontoid fractures treated within the first 6 months of injury with direct anterior odontoid screw fixation have an 88% fusion rate, whereas fractures treated after 18 months have only a 25% fusion rate. In this review, we discuss the etiology, biomechanics, diagnosis, and treatment (including factors affecting fusion such as timing and fracture orientation options available for odontoid process fractures.

  5. Free-hand thoracic pedicle screws placed by neurosurgery residents: a CT analysis

    Wang, Vincent Y.; Chin, Cynthia T.; Lu, Daniel C.; Smith, Justin S.; Chou, Dean


    Free-hand thoracic pedicle screw placement is becoming more prevalent within neurosurgery residency training programs. This technique implements anatomic landmarks and tactile palpation without fluoroscopy or navigation to place thoracic pedicle screws. Because this technique is performed by surgeons in training, we wished to analyze the rate at which these screws were properly placed by residents by retrospectively reviewing the accuracy of resident-placed free-hand thoracic pedicle screws u...

  6. Biomechanical and histological evaluation of roughened surface titanium screws fabricated by electron beam melting.

    Jun Yang

    Full Text Available BACKGROUND: Various fabrication methods are used to improve the stability and osseointegration of screws within the host bone. The aim of this study was to investigate whether roughened surface titanium screws fabricated by electron beam melting can provide better stability and osseointegration as compared with smooth titanium screws in sheep cervical vertebrae. METHODS: Roughened surface titanium screws, fabricated by electron beam melting, and conventional smooth surface titanium screws were implanted into sheep for 6 or 12 weeks (groups A and B, respectively. Bone ingrowth and implant stability were assessed with three-dimensional imaging and reconstruction, as well as histological and biomechanical tests. RESULTS: No screws in either group showed signs of loosening. Fibrous tissue formation could be seen around the screws at 6 weeks, which was replaced with bone at 12 weeks. Bone volume/total volume, bone surface area/bone volume, and the trabecular number were significantly higher for a define region of interest surrounding the roughened screws than that surrounding the smooth screws at 12 weeks. Indeed, for roughened screws, trabecular number was significantly higher at 12 weeks than at 6 weeks. On mechanical testing, the maximum pullout strength was significantly higher at 12 weeks than at 6 weeks, as expected; however, no significant differences were found between smooth and roughened screws at either time point. The maximum torque to extract the roughened screws was higher than that required for the smooth screws. CONCLUSIONS: Electron beam melting is a simple and effective method for producing a roughened surface on titanium screws. After 12 weeks, roughened titanium screws demonstrated a high degree of osseointegration and increased torsional resistance to extraction over smooth titanium screws.

  7. Biomechanical and histological evaluation of roughened surface titanium screws fabricated by electron beam melting.

    Yang, Jun; Cai, Hong; Lv, Jia; Zhang, Ke; Leng, Huijie; Wang, Zhiguo; Liu, Zhongjun


    Various fabrication methods are used to improve the stability and osseointegration of screws within the host bone. The aim of this study was to investigate whether roughened surface titanium screws fabricated by electron beam melting can provide better stability and osseointegration as compared with smooth titanium screws in sheep cervical vertebrae. Roughened surface titanium screws, fabricated by electron beam melting, and conventional smooth surface titanium screws were implanted into sheep for 6 or 12 weeks (groups A and B, respectively). Bone ingrowth and implant stability were assessed with three-dimensional imaging and reconstruction, as well as histological and biomechanical tests. No screws in either group showed signs of loosening. Fibrous tissue formation could be seen around the screws at 6 weeks, which was replaced with bone at 12 weeks. Bone volume/total volume, bone surface area/bone volume, and the trabecular number were significantly higher for a define region of interest surrounding the roughened screws than that surrounding the smooth screws at 12 weeks. Indeed, for roughened screws, trabecular number was significantly higher at 12 weeks than at 6 weeks. On mechanical testing, the maximum pullout strength was significantly higher at 12 weeks than at 6 weeks, as expected; however, no significant differences were found between smooth and roughened screws at either time point. The maximum torque to extract the roughened screws was higher than that required for the smooth screws. Electron beam melting is a simple and effective method for producing a roughened surface on titanium screws. After 12 weeks, roughened titanium screws demonstrated a high degree of osseointegration and increased torsional resistance to extraction over smooth titanium screws.

  8. Posterior atlantoaxial transpedicle screw fixation for traumatic atlatoaxial instability

    Zheng-lei WANG


    Full Text Available Objective To explore the clinical efficacy of posterior atlantoaxial pedicle screw fixation for traumatic atlantoaxial instability. Methods From September 2009 to March 2013, 17 patients with atlantoaxial instability received posterior atlantoaxial pedicle screw fixation. There were 12 males and 5 females, with a mean age of 42 years old (ranged from 19 to 63 years old. Transpedicle screw fixation was employed in 8 patients with atlantoaxial fracture and dislocation, in 2 with traumatic disruption of transverse atlantal ligament, and in 7 with odontoid fracture. The Japanese Orthopaedic Association (JOA score before operation was from 5 to 14, with a mean of 11.2. Preoperative CT, MRI and radiographs, as well as intraoperative screw placement and bone graft were administered in all the patients. Results In all the patients, complete reduction was achieved without injury to the vertebral artery, spinal cord or never root, and they started to be ambulatory on the first day after the operation. The patients were followed up for 6-36 months (mean 21 months, and clinical symptoms were seen to be improved significantly. Imaging reexamination 6 months after the surgery showed satisfactory healing of implanted bone and position of all the screws without loosening of the implant. The mean JOA scores was 15.5(11.0-17.0 twelve months after the operation. Conclusion Atlantoaxial pedicle screw fixation for traumatic atlantoaxial instability is safe and reliable with a favorable clinical result. DOI: 10.11855/j.issn.0577-7402.2015.09.14

  9. Blocking screws for the treatment of distal femur fractures.

    Seyhan, Mustafa; Cakmak, Selami; Donmez, Ferdi; Gereli, Arel


    Intramedullary nailing is one of the most convenient biological options for treating distal femoral fractures. Because the distal medulla of the femur is wider than the middle diaphysis and intramedullary nails cannot completely fill the intramedullary canal, intramedullary nailing of distal femoral fractures can be difficult when trying to obtain adequate reduction. Some different methods exist for achieving reduction. The purpose of this study was determine whether the use of blocking screws resolves varus or valgus and translation and recurvatum deformities, which can be encountered in antegrade and retrograde intramedullary nailing. Thirty-four patients with distal femoral fractures underwent intramedullary nailing between January 2005 and June 2011. Fifteen patients treated by intramedullary nailing and blocking screws were included in the study. Six patients had distal diaphyseal fractures and 9 had distal diaphyseo-metaphyseal fractures. Antegrade nailing was performed in 7 patients and retrograde nailing was performed in 8. Reduction during surgery and union during follow-up were achieved in all patients with no significant complications. Mean follow-up was 26.6 months. Mean time to union was 12.6 weeks. The main purpose of using blocking screws is to achieve reduction, but they are also useful for maintaining permanent reduction. When inserting blocking screws, the screws must be placed 1 to 3 cm away from the fracture line to avoid from propagation of the fracture. When applied properly and in an adequate way, blocking screws provide an efficient solution for deformities encountered during intramedullary nailing of distal femur fractures. Copyright 2013, SLACK Incorporated.

  10. Screw-in forces during instrumentation by various file systems


    Objectives The purpose of this study was to compare the maximum screw-in forces generated during the movement of various Nickel-Titanium (NiTi) file systems. Materials and Methods Forty simulated canals in resin blocks were randomly divided into 4 groups for the following instruments: Mtwo size 25/0.07 (MTW, VDW GmbH), Reciproc R25 (RPR, VDW GmbH), ProTaper Universal F2 (PTU, Dentsply Maillefer), and ProTaper Next X2 (PTN, Dentsply Maillefer, n = 10). All the artificial canals were prepared to obtain a standardized lumen by using ProTaper Universal F1. Screw-in forces were measured using a custom-made experimental device (AEndoS-k, DMJ system) during instrumentation with each NiTi file system using the designated movement. The rotation speed was set at 350 rpm with an automatic 4 mm pecking motion at a speed of 1 mm/sec. The pecking depth was increased by 1 mm for each pecking motion until the file reach the working length. Forces were recorded during file movement, and the maximum force was extracted from the data. Maximum screw-in forces were analyzed by one-way ANOVA and Tukey's post hoc comparison at a significance level of 95%. Results Reciproc and ProTaper Universal files generated the highest maximum screw-in forces among all the instruments while M-two and ProTaper Next showed the lowest (p < 0.05). Conclusions Geometrical differences rather than shaping motion and alloys may affect the screw-in force during canal instrumentation. To reduce screw-in forces, the use of NiTi files with smaller cross-sectional area for higher flexibility is recommended. PMID:27847752

  11. Osteotomy in direct sinus lift. A comparative study of the rotary technique and ultrasound

    Peñarrocha-Diago, María; Peñarrocha-Diago, Miguel; Sanchez-Recio, Cristina; Peñarrocha-Oltra, David; Romero-Millán, Javier


    The present study investigates sinus membrane rupture in direct maxillary sinus lift with the rotary technique and with ultrasound, examining the survival of implants placed after sinus augmentation...

  12. Combustion of large solid fuels in cement rotary kilns

    Nielsen, Anders Rooma


    The cement industry has a significant interest in replacing fossil fuels with alternative fuels in order to minimize production costs and reduce CO{sub 2} emissions. These new alternative fuels are in particular solid fuels such as refuse derived fuel (RDF), tire-derived fuel (TDF), meat and bone meal (MBM), waste wood, sewage sludge, paper and plastics. This thesis provides an insight into the utilization of solid alternative fuels in the material inlet end of rotary kilns. This position is interesting because it allows utilization of large fuel particles, thereby eliminating the need for an expensive shredding of the fuels. The challenge, however, is that the solid fuels will be mixed into the cement raw materials, which is likely to affect process stability and clinker quality, as described above. The mixing of fuels and raw materials was studied experimentally in a pilot-scale rotary drum and was found to be a fast process, reaching steady state within few drum revolutions. Thus, heat transfer by conduction from the cement raw materials to the fuel particles is a major heat transfer mechanism rather than convection or radiation from the freeboard gas above the material bed. Consequently, the temperature of the cement raw materials becomes a factor of great importance for heating the fuel particles. Combustion of different alternative fuels has been investigated experimentally in a pilot-scale rotary furnace under conditions similar to those in the material inlet end of cement rotary kilns. The main focus was on tire rubber and pine wood which are relevant fuels in this context. Heating, drying and devolatilization of alternative fuels are fast processes that primarily depend on heat transfer and fuel particle size. Devolatilization of a large wood or tire particle with a thickness of 20 mm at 900 deg. C is for example around 2 minutes. By contrast, char oxidation is a slow process which may greatly reduce the amounts of solid fuels to be utilized in the

  13. Virtual estimates of fastening strength for pedicle screw implantation procedures

    Linte, Cristian A.; Camp, Jon J.; Augustine, Kurt E.; Huddleston, Paul M.; Robb, Richard A.; Holmes, David R.


    Traditional 2D images provide limited use for accurate planning of spine interventions, mainly due to the complex 3D anatomy of the spine and close proximity of nerve bundles and vascular structures that must be avoided during the procedure. Our previously developed clinician-friendly platform for spine surgery planning takes advantage of 3D pre-operative images, to enable oblique reformatting and 3D rendering of individual or multiple vertebrae, interactive templating, and placement of virtual pedicle implants. Here we extend the capabilities of the planning platform and demonstrate how the virtual templating approach not only assists with the selection of the optimal implant size and trajectory, but can also be augmented to provide surrogate estimates of the fastening strength of the implanted pedicle screws based on implant dimension and bone mineral density of the displaced bone substrate. According to the failure theories, each screw withstands a maximum holding power that is directly proportional to the screw diameter (D), the length of the in-bone segm,ent of the screw (L), and the density (i.e., bone mineral density) of the pedicle body. In this application, voxel intensity is used as a surrogate measure of the bone mineral density (BMD) of the pedicle body segment displaced by the screw. We conducted an initial assessment of the developed platform using retrospective pre- and post-operative clinical 3D CT data from four patients who underwent spine surgery, consisting of a total of 26 pedicle screws implanted in the lumbar spine. The Fastening Strength of the planned implants was directly assessed by estimating the intensity - area product across the pedicle volume displaced by the virtually implanted screw. For post-operative assessment, each vertebra was registered to its homologous counterpart in the pre-operative image using an intensity-based rigid registration followed by manual adjustment. Following registration, the Fastening Strength was computed

  14. Posterior cervical spine arthrodesis with laminar screws: a report of two cases



    Full Text Available We performed fixation using laminar screws in 2 patients in whom lateral mass screws, pedicle screws or transarticular screws could not be inserted. One was a 56-year-old woman who had anterior atlantoaxial subluxation (AAS. When a guide wire was inserted using an imaging guide, the hole bled massively. We thought the re-insertion of a guide wire or screw would thus increase the risk of vascular injury, so we used laminar screws. The other case was an 18-year-old man who had a hangman fracture. Preoperative magnetic resonance angiography showed occlusion of the left vertebral artery. A laminar screw was inserted into the patent side (i.e., the right side of C2. Cervical pedicle screws are the most biomechanically stable screws. However, their use carries a high risk of neurovascular complications during screw insertion, because the cervical pedicle is small and is adjacent laterally to the vertebral artery, medially to the spinal cord, and vertically to the nerve roots. Lateral mass screws are also reported to involve a risk of neurovascular injuries. The laminar screw method was thus thought to be useful, since arterial injuries could thus be avoided and it could also be used as a salvage modality for the previous misinsertion.

  15. 46 CFR 154.524 - Piping joints: Welded and screwed couplings.


    ... 46 Shipping 5 2010-10-01 2010-10-01 false Piping joints: Welded and screwed couplings. 154.524... Equipment Cargo and Process Piping Systems § 154.524 Piping joints: Welded and screwed couplings. Pipe... warmer. (d) Screwed couplings are allowed for instrumentation and control piping that meets §...

  16. The best location for proximal locking screw for femur interlocking nailing: A biomechanical study

    Ahmet A Karaarslan


    Conclusion: According to our findings, there is twice as much difference in locking screw bending resistance between these two application levels. To avoid proximal locking screw deformation, locking screws should be placed in the level of the lesser trochanter in nailing of 1/3 middle and distal femur fractures.

  17. Screw angulation affects bone-screw stresses and bone graft load sharing in anterior cervical corpectomy fusion with a rigid screw-plate construct: a finite element model study.

    Hussain, Mozammil; Natarajan, Raghu N; Fayyazi, Amir H; Braaksma, Brian R; Andersson, Gunnar B J; An, Howard S


    Anterior corpectomy and reconstruction with bone graft and a rigid screw-plate construct is an established procedure for treatment of cervical neural compression. Despite its reliability in relieving symptoms, there is a high rate of construct failure, especially in multilevel cases. There has been no study evaluating the biomechanical effects of screw angulation on construct stability; this study investigates the C4-C7 construct stability and load-sharing properties among varying screw angulations in a rigid plate-screw construct. A finite element model of a two-level cervical corpectomy with static anterior cervical plate. A three-dimensional finite element (FE) model of an intact C3-T1 segment was developed and validated. From this intact model, a fusion model (two-level [C5, C6] anterior corpectomy) was developed and validated. After corpectomy, allograft interbody fusion with a rigid anterior screw-plate construct was created from C4 to C7. Five additional FE models were developed from the fusion model corresponding to five different combinations of screw angulations within the vertebral bodies (C4, C7): (0 degrees, 0 degrees), (5 degrees, 5 degrees), (10 degrees, 10 degrees), (15 degrees, 15 degrees), and (15 degrees, 0 degrees). The fifth fusion model was termed as a hybrid fusion model. The stability of a two-level corpectomy reconstruction is not dependent on the position of the screws. Despite the locked screw-plate interface, some degree of load sharing is transmitted to the graft. The load seen by the graft and the shear stress at the bone-screw junction is dependent on the angle of the screws with respect to the end plate. Higher stresses are seen at more divergent angles, particularly at the lower level of the construct. This study suggests that screw divergence from the end plates not only increases load transmission to the graft but also predisposes the screws to higher shear forces after corpectomy reconstruction. In particular, the inferior screw

  18. The Artful Universe Expanded

    Bassett, B A [Institute of Cosmology and Gravitation, University of Portsmouth (United Kingdom)


    The cosmos is an awfully big place and there is no better guide to its vast expanse and fascinating nooks and crannies than John Barrow. A professor of mathematical sciences at Cambridge University, Barrow embodies that rare combination of highly polished writer and expert scientist. His deft touch brings together the disparate threads of human knowledge and weaves them into a tapestry as rich and interesting for the expert as it is for the layperson. The Artful Universe Expanded is an updated edition of this popular book first published in 1995. It explores the deeply profound manner in which natural law and the nature of the cosmos have moulded and shaped us, our cultures and the very form of our arts and music-a new type of 'cosmic' anthropology. The main themes Barrow chooses for revealing this new anthropology are the subjects of evolution, the size of things, the heavens and the nature of music. The book is a large, eclectic repository of knowledge often unavailable to the layperson, hidden in esoteric libraries around the world. It rivals The Da Vinci Code for entertainment value and insights, but this time it is Nature's code that is revealed. It is rare indeed to find common threads drawn through topics as diverse as The Beetles, Bach and Beethoven or between Jackson Pollock, the Aztecs, Kant, Picasso, Byzantine mosaics, uranium-235 and the helix nebula. Barrow unerringly binds them together, presenting them in a stimulating, conversational style that belies the amount of time that must have gone into researching this book. Dip into it at random, or read it from cover to cover, but do read it. The Artful Universe Expanded is an entertaining antidote to the oft-lamented pressures to know more and more about less and less and the apparently inexorable march of specialization. On reading this book one can, for a short time at least, hold in one's mind a vision that unifies science, art and culture and glimpse a universal tapestry of great

  19. Role of rod diameter in comparison between only screws versus hooks and screws in posterior instrumentation of thoracic curve in idiopathic scoliosis.

    Lamartina, Claudio; Petruzzi, Maria; Macchia, Marcello; Stradiotti, Paola; Zerbi, Alberto


    Since the introduction of Cotrel-Dubousset instrumentation in 1984, the correction techniques in scoliosis surgery have changed from Harrington principles of concave distraction to segmental realignment to a variety of possibilities including the rod rotation manoeuvres, and to segmental approximation via cantilever methods. Additionally, pedicle screw utilization in lumbar curves enhanced correction and stabilization of various deformities, and various studies have strongly supported the clinical advantages of lumbar pedicle screws versus conventional hook instrumentation. Pedicle screw constructs have become increasingly popular in the treatment of patients with spinal deformity. When applied to adolescent idiopathic scoliosis patients, pedicle screw fixation has demonstrated increased corrective ability compared with traditional hook/hybrid instrumentation. In our study, we do a retrospective review of idiopathic scoliosis patients (King 2-Lenke 1 B/C) treated with a selective thoracic posterior fusion using an all-screw construct versus a hybrid (pedicle screws and hooks) construct and, compare the percentage of correction of the scoliotic curves obtained with screws alone and screws and hooks. Special attention was given to the rod diameter and correction technique. Our results show that the percentage of correction of idiopathic thoracic scoliosis is similar when treating the scoliosis with rods and screws alone or with rods, screws and hooks; therefore, we and the majority of authors in the literature do not consider the rod section. This can be an important parameter in the evaluation of the superiority of treatment with screws only or screws and hooks. In our study, even if not of statistical significance, the better thoracic curve correction obtained with the hybrid group should be ascribed to the fact that in this group mostly 6 mm rods were used.

  20. Atomistic simulations of jog migration on extended screw dislocations

    Vegge, T.; Leffers, T.; Pedersen, O.B.;


    We have performed large-scale atomistic simulations of the migration of elementary jogs on dissociated screw dislocations in Cu. The local crystalline configurations, transition paths. effective masses. and migration barriers for the jogs are determined using an interatomic potential based on the...

  1. 21 CFR 888.3070 - Pedicle screw spinal system.


    ... treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and... conditions are significant mechanical instability or deformity of the thoracic, lumbar, and sacral spine... screw spinal system because this is a technically demanding procedure presenting a risk of...

  2. Sacroiliac screw fixation: A mini review of surgical technique

    Hernando Raphael Alvis-Miranda


    Full Text Available The sacral percutaneous fixation has many advantages but can be associated with a significant exposure to X-ray radiation. Currently, sacroiliac screw fixation represents the only minimally invasive technique to stabilize the posterior pelvic ring. It is a technique that should be used by experienced surgeons. We present a practical review of important aspects of this technique.

  3. Sacroiliac screw fixation: A mini review of surgical technique

    Alvis-Miranda, Hernando Raphael; Farid-Escorcia, Hector; Alcalá-Cerra, Gabriel; Castellar-Leones, Sandra Milena; Moscote-Salazar, Luis Rafael


    The sacral percutaneous fixation has many advantages but can be associated with a significant exposure to X-ray radiation. Currently, sacroiliac screw fixation represents the only minimally invasive technique to stabilize the posterior pelvic ring. It is a technique that should be used by experienced surgeons. We present a practical review of important aspects of this technique. PMID:25336831

  4. Ankle fusion using a 2-incision, 3-screw technique

    R.P.M. Hendrickx; G.M.M.J. Kerkhoffs; S.A.S. Stufkens; C.N. van Dijk; R.K. Marti


    Reliable fusion and optimal correction of the alignment of the ankle joint using a 2-incision, 3-screw technique. Symptomatic osteoarthritis of the ankle joint after insufficient other treatment, severe deformity of the osteoarthritic ankle joint, or salvation procedure after failed arthroplasty. Ac

  5. Are inclined screw blades for vertical grain augers advantageous?

    Rademacher, F.J.C.


    Due to modern technology, screw blades are often manufactured by rolling them out of one single strip of steel. When simultaneously some blade inclination is applied, less residual stresses and/or larger possible ratios between outer and shaft diameter are claimed by some manufacturers, which seems

  6. Coupled Thermodynamic Behavior of New Screw Compressors Rotors Profile

    Arístides Rivera Torres


    Full Text Available The article displays an evaluation of the thermodynamic behavior of screw compressor rotors with new profiles, obtained with the help of the Scorpath 2000 software. This allows predicting precisely the operation of the compressor, as well as its thermodynamic evaluation, under equal conditions, with the work of other compressors fitted with rotor profiles of other kinds.

  7. Residence time distribution in twin-screw extruders.

    Jager, T.


    For the twin-screw extruders used in the food industry at short time high temperature processes the knowledge of their reactor properties is incomplete for mass- and heat flow. Therefore each process change such as: scale-up or product development requires a great number of measurements before an ac

  8. Kinematics of a Hybrid Manipulator by Means of Screw Theory

    Gallardo-Alvarado, J [Department of Mechanical Engineering, Instituto Tecnologico de Celaya (Mexico)


    In this work the kinematics of a hybrid manipulator, namely a fully parallel-serial manipulator, with a particular topology is approached by means of the theory of screws. Given the length of the six independent limbs, the forward position analysis of the mechanism under study, indeed the computation of the resulting pose, position and orientation, of the end-platform with respect to the fixed platform, is carried out in closed-form solution. Therefore conveniently this initial analysis avoids the use of a numerical technique such as the Newton-Raphson method. Writing in screw form the reduced acceleration state of the translational platform, with respect to the fixed platform, a simple expression for the computation of the acceleration of the translational platform is derived by taking advantage of the properties of reciprocal screws, via the Klein form, a bilinear symmetric form of the Lie algebra e(3). Following a similar procedure, a simple expression for the computation of the angular acceleration of the end-platform, with respect to the translational platform, is easily derived. Naturally, as an intermediate step, this contribution also provides the forward and inverse velocity analyses of the chosen parallel-serial manipulator. Finally, in order to prove the versatility of the expressions obtained via screw theory for solving the kinematics, up to the acceleration analysis, of the proposed spatial mechanism, a numerical example is solved with the help of commercial computer codes.

  9. Residence time distribution in twin-screw extruders

    Jager, T.


    For the twin-screw extruders used in the food industry at short time high temperature processes the knowledge of their reactor properties is incomplete for mass- and heat flow. Therefore each process change such as: scale-up or product development requires a great number of measurements

  10. Design of new silencers for a screw compressor

    Lier, L.J. van; Korst, H.J.C.; Smeulers, J.P.M.


    Two screw compressors used for the recycling of waste gas showed high vibration in the discharge piping. To mitigate the vibration problems new silencers had to be designed. A great challenge was the large variation in operating conditions, especially the variation of the molecular weight of the

  11. Optimisation of acoustic silencer for the screw compressor system

    Swamy, M.; Lier, L.J. van; Smeulers, J.P.M.


    In one of the screw compressor system, designed silencer was not optimal. A great challenge was the large variation in operating conditions, especially the variation of the molecular weight of the gas. There was need to optimize the silencer. This paper describes the acoustic modelling tools to

  12. Local mixing effects of screw elements during extrusion

    Einde, van den R.M.; Kroon, P.J.; Goot, van der A.J.; Boom, R.M.


    An in-line method was applied to determine local residence time distribution (RTD) at two places in a completely filled corotating twin screw extruder. Axial mixing effects of different types of elements were evaluated. Paddles +90 degrees induced flow patterns that appear to be circular, both

  13. Optimisation of acoustic silencer for the screw compressor system

    Swamy, M.; Lier, L.J. van; Smeulers, J.P.M.


    In one of the screw compressor system, designed silencer was not optimal. A great challenge was the large variation in operating conditions, especially the variation of the molecular weight of the gas. There was need to optimize the silencer. This paper describes the acoustic modelling tools to opti

  14. Kinematics Analysis Based on Screw Theory of a Humanoid Robot

    MAN Cui-hua; FAN Xun; LI Cheng-rong; ZHAO Zhong-hui


    A humanoid robot is a complex dynamic system for its idiosyncrasy. This paper aims to provide a mathematical and theoretical foundation for the design of the configuration, kinematics analysis of a novel humanoid robot. It has a simplified configuration and design for entertainment purpose. The design methods, principle and mechanism are discussed. According to the design goals of this research, there are ten degrees of freedom in the two bionic arms.Modularization, concurrent design and extension theory methods were adopted in the configuration study and screw theory was introduced into the analysis of humanoid robot kinematics. Comparisons with other methods show that: 1) only two coordinates need to be established in the kinematics analysis of humanoid robot based on screw theory; 2) the spatial manipulator Jacobian obtained by using twist and exponential product formula is succinct and legible; 3) adopting screw theory to resolve the humanoid robot arms kinematics question can avoid singularities; 4) using screw theory can solve the question of specification insufficiency.

  15. [Posterior atlantoaxial fixation using vertex multiaxial screw system].

    Zhong, Dejun; Song, Yueming


    This study aims to assess the effectiveness and advantages of Vertex multiaxial screw system in use for stabilizing the atlanto-axial junction. The entry point of the atlas was located 18-20 mm lateral to the midline and 2.0 mm superior to the inferior border of posterior arch, and the direction of screw was chosen to be about 10 degrees medial to the sagittal plane and about 5 degrees cephalad to the transverse plane. In odontoid vertebra (C2), the direction of the drill bit was guided directly by the medial and superior aspect of the individual C2 pedicle. All screws were placed properly without incidence of nerve or blood vessel injury, and no complication appeared in operation and after surgery. All cases were followed up for an average of 9 months, all cases achieved well reposition and fixation of atlantoaxial joint, average JOA grade was 9.6 before preoperation and 15.9 after operation. Fixation of the atlantoaxial complex using Vertex multiaxial screw system seemed to be a reliable technique and should be considered a good alternative in atlantoaxial fusion. The technique could be used in young patiens.

  16. Internally geared screw machines with ported end plates

    Read, M. G.; Smith, I. K.; Stosic, N.


    It is possible to design cylindrical helical gearing profiles such that an externally lobed inner gear rotates inside an internally lobed outer gear while maintaining continuous lines of contact between the gears. The continuous contact between the inner and outer rotors (analogous to the main and gate rotors in a conventional screw machine) creates a series of separate working chambers. In this type of machine the rotors have parallel axes of rotation, and if both rotors are free to rotate about their own axes, these axes can be fixed in space. The use of ported end plates is proposed to control the period during which fluid is allowed to enter or leave the working chambers of the internally geared screw machine. As with conventional screw machines, these internally geared rotors can then be used to achieve compression or expansion of a trapped mass of fluid, and the machine geometry can be designed in order to optimise performance for particular applications. This paper describes the geometrical analysis of some simple rotor profiles and explores the effect on rotor torques for particular applications of this novel screw configuration.

  17. Granulation of increasingly hydrophobic formulations using a twin screw granulator.

    Yu, Shen; Reynolds, Gavin K; Huang, Zhenyu; de Matas, Marcel; Salman, Agba D


    The application of twin screw granulation in the pharmaceutical industry has generated increasing interest due to its suitability for continuous processing. However, an understanding of the impact of formulation properties such as hydrophobicity on intermediate and finished product quality has not yet been established. Hence, the current work investigated the granulation behaviour of three formulations containing increasing amounts of hydrophobic components using a Consigma™-1 twin screw granulator. Process conditions including powder feed rate, liquid to solid ratio, granulation liquid composition and screw configuration were also evaluated. The size of the wet granules was measured in order to enable exploration of granulation behaviour in isolation without confounding effects from downstream processes such as drying. The experimental observations indicated that the granulation process was not sensitive to the powder feed rate. The hydrophobicity led to heterogeneous liquid distribution and hence a relatively large proportion of un-wetted particles. Increasing numbers of kneading elements led to high shear and prolonged residence time, which acted to enhance the distribution of liquid and feeding materials. The bimodal size distributions considered to be characteristic of twin screw granulation were primarily ascribed to the breakage of relatively large granules by the kneading elements.

  18. Design of a magnetic lead screw for wave energy conversion

    Holm, Rasmus Koldborg; Berg, Nick Ilsoe; Walkusch, Morten


    This paper deals with the development of a magnetic lead screw (MLS) for wave energy conversion. Initially, a brief state of the art regarding linear permanent-magnet generators and MLSs is given, leading to an introduction of the MLS and a presentation of the results from a finite-element analysis...


    Fang Hairong; Fang Yuefa; Guo Sheng


    Structural synthesis for 4-DOF parallel manipulators using screw theory is systematically studied. Motion properties and constraint conditions of 4-DOF parallel manipulators according to the relationship between screw and reciprocal screw are analyzed. Mathematical expressions for constraint screws and twist screws of moving platform are constructed, and all possible limbs, which provide one or more force constraints, are enumerated. Finally, a parallel manipulator with 3-rotation-DOF and 1-translation-DOF is used as an example to describe the synthesis procedure for symmetrical and non-symmetrical 4-DOF parallel manipulators.

  20. Effects of lag screw design and lubrication on sliding in trochanteric nails.

    Kummer, Frederick J


    This study compared the sliding characteristics of three lag screw designs used with trochanteric nails and determined the effects of lubrication on sliding. They were tested by an established method to measure initiation and ease of lag screw sliding. These tests were then repeated with calf serum lubrication. There were significant differences (p Lubrication did not affect either parameter. Lag screw design aspects, such as diameter and, particularly, surface finish, affect sliding. Due to the small contact area between the lag screw and nail creating high interface stresses, lubrication had no effect on lag screw sliding.

  1. Use of computational fluid dynamics simulations for design of a pretreatment screw conveyor reactor.

    Berson, R Eric; Hanley, Thomas R


    Computational fluid dynamics simulations were employed to compare performance of various designs of a pretreatment screw conveyor reactor. The reactor consisted of a vertical screw used to create cross flow between the upward conveying solids and the downward flow of acid. Simulations were performed with the original screw design and a modified design in which the upper flights of the screw were removed. Results of the simulations show visually that the modified design provided favorable plug flow behavior within the reactor. Pressure drop across the length of the reactor without the upper screws in place was predicted by the simulations to be 5 vs 40 kPa for the original design.

  2. A technique for the management of screw access opening in cement-retained implant restorations

    Hamid Kermanshah


    Full Text Available Introduction: Abutment screw loosening has been considered as a common complication of implant-supported dental prostheses. This problem is more important in cement-retained implant restorations due to their invisible position of the screw access opening. Case Report: This report describes a modified retrievability method for cement-retained implant restorations in the event of abutment screw loosening. The screw access opening was marked with ceramic stain and its porcelain surface was treated using hydrofluoric acid (HF, silane, and adhesive to bond to composite resin. Discussion: The present modified technique facilitates screw access opening and improves the bond between the porcelain and composite resin.

  3. Covering the screw-access holes of implant restorations in the esthetic zone: a clinical report.

    Abolfazl Saboury


    Full Text Available Screw-retained implant restorations have an advantage of predictable retention as well as retrievability, and obviate the risk of excessive sub-gingival cement commonly associated with cement retained implant restorations. Screw-retained restorations generally have screw access holes, which can compromise esthetics and weaken the porcelain around the holes. The purpose of this study is to describe the use of a separate overcasting crown design to cover the screw access hole of implant screw-retained prosthesis for improved esthetics.

  4. Placement of thoracic transvertebral pedicle screws using 3D image guidance.

    Nottmeier, Eric W; Pirris, Stephen M


    Transvertebral pedicle screws have successfully been used in the treatment of high-grade L5-S1 spondylolisthesis. An advantage of transvertebral pedicle screws is the purchase of multiple cortical layers across 2 vertebrae, thereby increasing the stability of the construct. At the lumbosacral junction, transvertebral pedicle screws have been shown to be biomechanically superior to pedicle screws placed in the standard fashion. The use of transvertebral pedicle screws at spinal levels other than L5-S1 has not been reported in the literature. The authors describe their technique of transvertebral pedicle screw placement in the thoracic spine using 3D image guidance. Twelve patients undergoing cervicothoracic or thoracolumbar fusion had 41 thoracic transvertebral pedicle screws placed across 26 spinal levels using this technique. Indications for placement of thoracic transvertebral pedicle screws in earlier cases included osteoporosis and pedicle screw salvage. However, in subsequent cases screws were placed in patients undergoing multilevel thoracolumbar fusion without osteoporosis, particularly near the top of the construct. Image guidance in this study was accomplished using the Medtronic StealthStation S7 image guidance system used in conjunction with the O-arm. All patients were slated to undergo postoperative CT scanning at approximately 4-6 months for fusion assessment, which also allowed for grading of the transvertebral pedicle screws. No thoracic transvertebral pedicle screw placed in this study had to be replaced or repositioned after intraoperative review of the cone beam CT scans. Review of the postoperative CT scans revealed all transvertebral screws to be across the superior disc space with the tips in the superior vertebral body. Six pedicle screws were placed using the in-out-in technique in patients with narrow pedicles, leaving 35 screws that underwent breach analysis. No pedicle breach was noted in 34 of 35 screws. A Grade 1 (fusion was observed

  5. Experimental and Numerical Investigation of an Axial Rotary Blood Pump.

    Schüle, Chan Yong; Thamsen, Bente; Blümel, Bastian; Lommel, Michael; Karakaya, Tamer; Paschereit, Christian Oliver; Affeld, Klaus; Kertzscher, Ulrich


    Left ventricular assist devices (LVADs) have become a standard therapy for patients with severe heart failure. As low blood trauma in LVADs is important for a good clinical outcome, the assessment of the fluid loads inside the pump is critical. More specifically, the flow features on the surfaces where the interaction between blood and artificial material happens is of great importance. Therefore, experimental data for the near-wall flows in an axial rotary blood pump were collected and directly compared to computational fluid dynamic results. For this, the flow fields based on unsteady Reynolds-averaged Navier-Stokes simulations-computational fluid dynamics (URANS-CFD) of an axial rotary blood pump were calculated and compared with experimental flow data at one typical state of operation in an enlarged model of the pump. The focus was set on the assessment of wall shear stresses (WSS) at the housing wall and rotor gap region by means of the wall-particle image velocimetry technique, and the visualization of near-wall flow structures on the inner pump surfaces by a paint erosion method. Additionally, maximum WSS and tip leakage volume flows were measured for 13 different states of operation. Good agreement between CFD and experimental data was found, which includes the location, magnitude, and direction of the maximum and minimum WSS and the presence of recirculation zones on the pump stators. The maximum WSS increased linearly with pressure head. They occurred at the upstream third of the impeller blades and exceeded the critical values with respect to hemolysis. Regions of very high shear stresses and recirculation zones could be identified and were in good agreement with simulations. URANS-CFD, which is often used for pump performance and blood damage prediction, seems to be, therefore, a valid tool for the assessment of flow fields in axial rotary blood pumps. The magnitude of maximum WSS could be confirmed and were in the order of several hundred Pascal.

  6. The general theory of blade screws including propellers, fans, helicopter screws, helicoidal pumps, turbo-motors, and different kinds of helicoidal blades

    De Bothezat, George


    Report presents a theory which gives a complete picture and an exact quantitative analysis of the whole phenomenon of the working of blade screws, but also unites in a continuous whole the entire scale of states of work conceivable for a blade screw. Chapter 1 is devoted to the establishment of the system of fundamental equations relating to the blade screw. Chapter 2 contains the general discussion of the 16 states of work which may establish themselves for a blade screw. The existence of the vortex ring state and the whirling phenomenon are established. All the fundamental functions which enter the blade-screw theory are submitted to a general analytical discussion. The general outline of the curve of the specific function is examined. Two limited cases of the work of the screw, the screw with a zero constructive pitch and the screw with an infinite constructive pitch, are pointed out. Chapter 3 is devoted to the study of the propulsive screw or propeller. (author)

  7. Estimation of drying parameters in rotary dryers using differential evolution

    Lobato, F S; Jr, V Steffen; Barrozo, M A S; Arruda, E B, E-mail:, E-mail:


    Inverse problems arise from the necessity of obtaining parameters of theoretical models to simulate the behavior of the system for different operating conditions. Several heuristics that mimic different phenomena found in nature have been proposed for the solution of this kind of problem. In this work, the Differential Evolution Technique is used for the estimation of drying parameters in realistic rotary dryers, which is formulated as an optimization problem by using experimental data. Test case results demonstrate both the feasibility and the effectiveness of the proposed methodology.


    Mikhailov, V; E. Strock


    In order to obtain an adequate mathematical model of vehicle hydro-mechanical steering which is  equipped with a steering mechanism combined with power steering and a rotary distributor  it is initially   necessary to get current consumption values in the units of hydraulic scheme which are determined by dynamic changes of flow passages of pressure and drain circuits according to turning angle of the distributor. Such characteristics are usually determined experimentally.The paper  proposes  ...

  9. A rotary electromagnetic microgenerator for energy harvesting from human motions

    Mehdi Niroomand


    Full Text Available In this paper, a rotary electromagnetic microgenerator is analyzed, designed and built. This microgenerator can convert human motions to electrical energy. The small size and use of a pendulum mechanism without gear are two main characteristics of the designed microgenerator. The generator can detect small vibrations and produce electrical energy. The performance of this microgenerator is evaluated by being installed peak-to-peak during normal walking. Also, the maximum harvested electrical energy during normal walking is around 416.6 μW. This power is sufficient for many applications.

  10. System and method for cooling a superconducting rotary machine

    Ackermann, Robert Adolf; Laskaris, Evangelos Trifon; Huang, Xianrui; Bray, James William


    A system for cooling a superconducting rotary machine includes a plurality of sealed siphon tubes disposed in balanced locations around a rotor adjacent to a superconducting coil. Each of the sealed siphon tubes includes a tubular body and a heat transfer medium disposed in the tubular body that undergoes a phase change during operation of the machine to extract heat from the superconducting coil. A siphon heat exchanger is thermally coupled to the siphon tubes for extracting heat from the siphon tubes during operation of the machine.


    Giacobbe Braccio


    Full Text Available This work deals with the simulation of an olive pits fed rotary kiln pyrolysis plant installed in Southern Italy. The pyrolysis process was simulated by commercial software CHEMCAD. The main component of the plant, the pyrolyzer, was modelled by a Plug Flow Reactor in accordance to the kinetic laws. Products distribution and the temperature profile was calculated along reactor's axis. Simulation results have been found to fit well the experimental data of pyrolysis. Moreover, sensitivity analyses were executed to investigate the effect of biomass moisture on the pyrolysis process.

  12. NASA Subsonic Rotary Wing Project - Structures and Materials Discipline

    Halbig, Michael C.; Johnson, Susan M.


    The Structures & Materials Discipline within the NASA Subsonic Rotary Wing Project is focused on developing rotorcraft technologies. The technologies being developed are within the task areas of: 5.1.1 Life Prediction Methods for Engine Structures & Components 5.1.2 Erosion Resistant Coatings for Improved Turbine Blade Life 5.2.1 Crashworthiness 5.2.2 Methods for Prediction of Fatigue Damage & Self Healing 5.3.1 Propulsion High Temperature Materials 5.3.2 Lightweight Structures and Noise Integration The presentation will discuss rotorcraft specific technical challenges and needs as well as details of the work being conducted in the six task areas.

  13. Equivalent Circuit Modeling of a Rotary Piezoelectric Motor

    El, Ghouti N.; Helbo, Jan


    In this paper, an enhanced equivalent circuit model of a rotary traveling wave piezoelectric ultrasonic motor "shinsei type USR60" is derived. The modeling is performed on the basis of an empirical approach combined with the electrical network method and some simplification assumptions about...... the physical behavior of the real system. This paper highlights the importance of the electromechanical coupling factor, which is responsible for the electrical to mechanical energy conversion. The emphasis is put on the difference between the effective coupling factor and the modal coupling factor. The effect...

  14. Shear Stress Transmission Model for the Flagellar Rotary Motor

    Hiroyuki Ohshima


    Full Text Available Most bacteria that swim are propelled by flagellar filaments, which are driven by a rotary motor powered by proton flux. The mechanism of the flagellar motor is discussed by reforming the model proposed by the present authors in 2005. It is shown that the mean strength of Coulomb field produced by a proton passing the channel is very strong in the Mot assembly so that the Mot assembly can be a shear force generator and induce the flagellar rotation. The model gives clear calculation results in agreement with experimental observations, e g., for the charasteristic torque-velocity relationship of the flagellar rotation.

  15. Rotary Percussive Auto-Gopher for Deep Drilling and Sampling

    Bar-Cohen, Yoseph; Badescu, Mircea; Sherrit, Stewart


    The term "rotary percussive auto-gopher" denotes a proposed addition to a family of apparatuses, based on ultrasonic/ sonic drill corers (USDCs), that have been described in numerous previous NASA Tech Briefs articles. These apparatuses have been designed, variously, for boring into, and/or acquiring samples of, rock or other hard, brittle materials of geological interest. In the case of the rotary percussive autogopher, the emphasis would be on developing an apparatus capable of penetrating to, and acquiring samples at, depths that could otherwise be reached only by use of much longer, heavier, conventional drilling-and-sampling apparatuses. To recapitulate from the prior articles about USDCs: A USDC can be characterized as a lightweight, low-power jackhammer in which a piezoelectrically driven actuator generates ultrasonic vibrations and is coupled to a tool bit through a free mass. The bouncing of the free mass between the actuator horn and the drill bit converts the actuator ultrasonic vibrations into sonic hammering of the drill bit. The combination of ultrasonic and sonic vibrations gives rise to a hammering action (and a resulting chiseling action at the tip of the tool bit) that is more effective for drilling than is the microhammering action of ultrasonic vibrations alone. The hammering and chiseling actions are so effective that the size of the axial force needed to make the tool bit advance into soil, rock, or another material of interest is much smaller than in ordinary rotary drilling, ordinary hammering, or ordinary steady pushing. The predecessor of the rotary percussive auto-gopher is an apparatus, now denoted an ultrasonic/sonic gopher and previously denoted an ultrasonic gopher, described in "Ultrasonic/ Sonic Mechanism for Drilling and Coring" (NPO-30291), NASA Tech Briefs Vol. 27, No. 9 (September 2003), page 65. The ultrasonic/sonic gopher is intended for use mainly in acquiring cores. The name of the apparatus reflects the fact that, like a

  16. Rotary Ultrasonic Machining of Poly-Crystalline Cubic Boron Nitride

    Kuruc Marcel


    Full Text Available Poly-crystalline cubic boron nitride (PCBN is one of the hardest material. Generally, so hard materials could not be machined by conventional machining methods. Therefore, for this purpose, advanced machining methods have been designed. Rotary ultrasonic machining (RUM is included among them. RUM is based on abrasive removing mechanism of ultrasonic vibrating diamond particles, which are bonded on active part of rotating tool. It is suitable especially for machining hard and brittle materials (such as glass and ceramics. This contribution investigates this advanced machining method during machining of PCBN.

  17. Bioresorbable screws reinforced with phosphate glass fibre: manufacturing and mechanical property characterisation.

    Felfel, R M; Ahmed, I; Parsons, A J; Rudd, C D


    Use of bioresorbable screws could eliminate disadvantages associated with metals such as removal operations, corrosion, MRI interference and stress shielding. Mechanical properties of bioresorbable polymers alone are insufficient for load bearing applications application as screws. Thus, reinforcement is necessary to try and match or surpass the mechanical properties of cortical bone. Phosphate based glass fibres were used to reinforce polylactic acid (PLA) in order to produce unidirectionally aligned (UD) and unidirectionally plus randomly distributed (UD/RM) composite screws (P40 UD and P40 UD/RM). The maximum flexural and push-out properties for the composite screws (P40 UD and P40 UD/RM) increased by almost 100% in comparison with the PLA screws. While the pull-out strength and stiffness of the headless composite screws were ∼80% (strength) and ∼130% (stiffness) higher than for PLA, those with heads exhibited properties lower than those for PLA alone as a result of failure at the heads. An increase in the maximum shear load and stiffness for the composite screws (∼30% and ∼40%) in comparison to the PLA screws was also seen. Maximum torque for the PLA screws was ∼1000 mN m, while that for the composite screws were slightly lower. The SEM micrographs for P40 UD and P40 UD/RM screws revealed small gaps around the fibres, which were suggested to be due to buckling of the UD fibres during the manufacturing process.

  18. Sauvé-Kapandji procedure with headless compression screw in patients with rheumatoid arthritis.

    Maeda, Atsushi; Suzuki, Taku; Hasegawa, Masaki; Kuroiwa, Takashi; Shizu, Kanae; Hayakawa, Katsuhiko; Tsuji, Takashi; Suzuki, Katsuji; Yamada, Harumoto


    We examined the surgical outcomes of the Sauvé-Kapandji (S-K) procedure using a headless compression screw and a metal cancellous screw in patients with rheumatoid arthritis (RA). This retrospective study included 41 RA patients who underwent the S-K procedure for distal radioulnar joint disorders with two screws: headless compression screws (HCS group, n = 20) and cannulated cancellous screws (CCS group, n = 21). Clinical and radiographic outcomes were assessed 1 year after surgery. Radiographic outcomes included bony union of the distal radioulnar joint (DRUJ), bone resorption around the screw, a screw back-out, and use of additional K-wire. We investigated any complications related to the screw head. All 20 patients in the HCS group showed bone fusion of the DRUJ. In the CCS group, an asymptomatic non-union was observed in one patient and additional K-wire was needed to stabilize the DRUJ in three patients. No patients complained of any complications related to the screw head in the HCS group, while the CCS group demonstrated the hardware protrusion in two patients who complained of tenderness or discomfort at the screw head. The use of a headless compression screw in the S-K procedure is useful in patients with RA.

  19. A rationale method for evaluating unscrewing torque values of prosthetic screws in dental implants

    Felipe Miguel Saliba


    Full Text Available OBJECTIVES: Previous studies that evaluated the torque needed for removing dental implant screws have not considered the manner of transfer of the occlusal loads in clinical settings. Instead, the torque used for removal was applied directly to the screw, and most of them omitted the possibility that the hexagon could limit the action of the occlusal load in the loosening of the screws. The present study proposes a method for evaluating the screw removal torque in an anti-rotational device independent way, creating an unscrewing load transfer to the entire assembly, not only to the screw. MATERIAL AND METHODS: Twenty hexagonal abutments without the hexagon in their bases were fixed with a screw to 20 dental implants. They were divided into two groups: Group 1 used titanium screws and Group 2 used titanium screws covered with a solid lubricant. A torque of 32 Ncm was applied to the screw and then a custom-made wrench was used for rotating the abutment counterclockwise, to loosen the screw. A digital torque meter recorded the torque required to loosen the abutment. RESULTS: There was a significant difference between the means of Group 1 (38.62±6.43 Ncm and Group 2 (48.47±5.04 Ncm, with p=0.001. CONCLUSION: This methodology was effective in comparing unscrewing torque values of the implant-abutment junction even with a limited sample size. It confirmed a previously shown significant difference between two types of screws.

  20. [Finite element analysis of the initial stability of subtalar arthrodesis with double-screw fixation].

    Cui, Zhuang; Yu, Bin; Li, Xue; Xu, Changpeng; Song, Jinqi; Ouyang, Hanbin; Diao, Xicai; Chen, Liguang


    To assess the optimal configuration of double-screw fixation for subtalar arthrodesis using finite element analysis. Three-dimensional finite element double-screw models of subtalar arthrodesis were reconstructed using Mimics 13.0, Geomagic 10.0 and solid works software based on the 3-D images of the volunteer's right foot. The external and internal rotation torques of 4 N·m were applied, and the micromotion at the bone-to-bone interface were measured to evaluate the initial stability of subtalar arthrodesis. A neck screw plus an anterolateral dome screw was the most stable model. The peak micromotion at the fusion site of this fixation configuration were 41.67mnplus;0.49 and 42.64mnplus;0.75 µm in response to the respectively. A neck screw plus a posteromedial dome screw was the least stable model, with peak micromotion at the bone-to-bone interface of 61.76mnplus;1.00 and 62.32mnplus;0.90 µm, respectively. A neck screw plus an anterolateral dome screw is the best fixation configuration while a neck screw plus a posteromedial screw provides the least stability of subtalar arthrodesis. Three-dimensional finite element models allow effective preoperative planning of the screw number and placement.

  1. Environmental impact assessment of combustible wastes utilization in rotary cement kilns


    This study focuses on the environmental impact assessment of the coal combustion and its substitution by alternative fuels from combustible wastes during Portland cement clinker sinterization in rotary cement kiln. Environmental impact assessment was carried out based on the fuels chemical composition and operating parameters of a rotary cement kiln in accordance with EURITS and IMPACT 2002+ methods.

  2. Effective incineration technology with a new-type rotary waste incinerator

    CHEN Lie-qiang; ZHU Jian-zhong; CAI Ming-zhao; XIE Xin-yuan


    The technology of steady combustion in a new type of rotary incinerator is firstly discussed. The formation and control of HCl, NOx and SO2 during the incineration of sampled municipal organic solid waste are studied with the incinerator. Results showed that the new model of rotary incinerator can effectively control and reduce the pollutant formations by post combustion.

  3. 1×N rotary vertical micromirror for optical switching applications

    Tu, Ching-Chen; Fanchiang, Kuohao; Liu, Cheng-Hsien


    We report a 1xN rotary optical switching mirror actuated by an electrostatic comb-driver for the optical networking. A variety of MEMS optical switching mirrors have been recently proposed. Some of these devices utilize surface micromachined films as reflection micromirrors and result in optical degradation. Some of these devices fabricated by bulk micromachining highly rely on delicate assembly for the micromirrors to the top of the actuators. In this paper, we focus on developing a rotary optical switching micromirror with no need of delicate assembly. The rotary actuator and the switching micromirror are both fabricated by deep RIE in our design. We use the Spin-On-Glass (SOG), which is used as the intermediated layer in the low temperature boning, to fabricate a rotary MEMS optical switching mirror with self-assembly. We successfully assemble the micromirror on top of the rotor stage of the rotary actuator. Experimental results show that our rotary vertical micromirror rotates about 1.5° under 150 volts. The first vibration mode of this rotary switching MEMS mirror is a rotary mode and appears around 3.4 kHz, which is measured via a Polytec laser doppler vibrometer.

  4. Biomechanical testing of bioabsorbable cannulated screws for slipped capital femoral epiphysis fixation.

    Kroeber, Markus W; Rovinsky, David; Haskell, Andrew; Heilmann, Moira; Llotz, Jeff; Otsuka, Norman


    This study compared cannulated 4.5-mm bioabsorbable screws made of self-reinforced poly-levolactic acid to cannulated 4.5-mm steel and titanium screws for resistance to shear stress and ability to generate compression in a polyurethane foam model of slipped capital femoral epiphysis fixation. The maximum shear stress resisted by the three screw types was similar (self-reinforced poly-levolactic acid 371 +/- 146 MPa, steel 442 +/- 43 MPa, and titanium 470 +/- 91 MPa). The maximum compression generated by both the self-reinforced poly-levolactic acid screw (68.5 +/- 3.3 N) and the steel screw (63.3 +/- 5.9 N) was greater than that for the titanium screw (3 +/- 1.4 N, P <.05). These data suggest cannulated self-reinforced poly-levolactic acid screws can be used in the treatment of slipped capital femoral epiphysis because of their sufficient biomechanical strength.

  5. Easy retrieval of polyaxial tulip-head pedicle screws by “U” rod technique

    Isik, Cengiz; Altinel, Levent; Ates, Ali; Ozdemir, Mustafa


    The number of fusion surgeries increase each year which also increase the need for implant removal. In some cases, it can be extremely hard to remove a pedicle screw especially when there is a mismatch of the screw and the screwdriver. Also the screwdrivers can be contaminated during the operation, and this will cause a delay till the instruments are re-sterilized. There is a need for the removal of screws without special instruments. We describe a method for removing tulip-head polyaxial pedicle screws without special instruments. The screws are removed using an Allen key, a rod bender and a “U” shaped rod. We successfully removed 76 screws in 11 recent cases without any complications. The “U” rod technique is a simple and useful technique for the removal of tulip-head polyaxial screws. PMID:19618219

  6. Easy retrieval of polyaxial tulip-head pedicle screws by "U" rod technique.

    Kose, Kamil Cagri; Isik, Cengiz; Altinel, Levent; Ates, Ali; Ozdemir, Mustafa


    The number of fusion surgeries increase each year which also increase the need for implant removal. In some cases, it can be extremely hard to remove a pedicle screw especially when there is a mismatch of the screw and the screwdriver. Also the screwdrivers can be contaminated during the operation, and this will cause a delay till the instruments are re-sterilized. There is a need for the removal of screws without special instruments. We describe a method for removing tulip-head polyaxial pedicle screws without special instruments. The screws are removed using an Allen key, a rod bender and a "U" shaped rod. We successfully removed 76 screws in 11 recent cases without any complications. The "U" rod technique is a simple and useful technique for the removal of tulip-head polyaxial screws.

  7. Time analysis for screw application: traditional lag technique versus self-tapping lag technique.

    Gonzalez, J V; Trout, B M; Stuck, R M; Vrbos, L A


    A study was conducted to compare the procedural time of a 2.7-mm. fully threaded cortical screw versus a self-tapping, 2.4-mm. lag screw, which is reported to eliminate the need for overdrilling and tapping. The screws were applied by four board-certified podiatric and orthopedic physicians and four second-year podiatric and orthopedic residents. Each screw was placed through two 8-mm. layers of Last-a-foam, and the participants were timed for length of application of four screws from each system per week. The trials were repeated weekly for 4 weeks. The results showed a statistically significant difference between the length of time for insertion between a traditional cortical screw and a self-tapping lag screw, regardless of physician experience.

  8. Screw Remaining Life Prediction Based on Quantum Genetic Algorithm and Support Vector Machine

    Xiaochen Zhang


    Full Text Available To predict the remaining life of ball screw, a screw remaining life prediction method based on quantum genetic algorithm (QGA and support vector machine (SVM is proposed. A screw accelerated test bench is introduced. Accelerometers are installed to monitor the performance degradation of ball screw. Combined with wavelet packet decomposition and isometric mapping (Isomap, the sensitive feature vectors are obtained and stored in database. Meanwhile, the sensitive feature vectors are randomly chosen from the database and constitute training samples and testing samples. Then the optimal kernel function parameter and penalty factor of SVM are searched with the method of QGA. Finally, the training samples are used to train optimized SVM while testing samples are adopted to test the prediction accuracy of the trained SVM so the screw remaining life prediction model can be got. The experiment results show that the screw remaining life prediction model could effectively predict screw remaining life.

  9. Evaluation of different screw fixation techniques and screw diameters in sagittal split ramus osteotomy: finite element analysis method.

    Sindel, A; Demiralp, S; Colok, G


    Sagittal split ramus osteotomy (SSRO) is used for correction of numerous congenital or acquired deformities in facial region. Several techniques have been developed and used to maintain fixation and stabilisation following SSRO application. In this study, the effects of the insertion formations of the bicortical different sized screws to the stresses generated by forces were studied. Three-dimensional finite elements analysis (FEA) and static linear analysis methods were used to investigate difference which would occur in terms of forces effecting onto the screws and transmitted to bone between different application areas. No significant difference was found between 1·5- and 2-mm screws used in SSRO fixation. Besides, it was found that 'inverted L' application was more successful compared to the others and that was followed by 'L' and 'linear' formations which showed close rates to each other. Few studies have investigated the effect of thickness and application areas of bicortical screws. This study was performed on both advanced and regressed jaws positions.

  10. Expanding contraceptive options.


    The goals of Family Health International (FHI) have been to introduce a variety of birth control options to people in developing countries, and to provide information to the user on the advantages and disadvantages of each method. FHI has worked with many developing countries in clinical trials of established as well as new contraceptive methods. These trials played an important part in making 2 sterilization procedures, laparoscopy and minilaparotomy popular for women. Further research improved the methods and have made them the most popular in the world, chosen by 130 million users. FHI is doing clinical trials on a new IUD, that is a copper bearing T-shaped device called the TCu380A. they have collected data on over 10,000 women using IUD's and early analysis indicates TCu380A is more effective than others. FHI is also evaluating devices such as Norplant that will prevent pregnancy up to 5 years by implanting the capsules in the arm. More than 8,000 women are being tested to determine the acceptability of implants in different geographical locations. Other research groups are doing work in 10 additional countries: Bangladesh will expand its program to 24,000 women and Nepal to 8,000 women. Trials are also being conducted on progestogen pills, since they do not lesson the volume of milk in breast feeding. FHI has also worked to introduce creative community-based distribution channels. In one case, specially trained health workers delivered contraceptives door-to-door in over 150,000 households. They found that 2 of 3 women accepted the pills and in a follow up survey 90% were still using them. FHI is now focusing on ways to improve moving new contraceptives from clinical testing on everyday use. They will coordinate training programs, educational material, media campaigns, and efforts with other international organizations, government agencies, and family planning groups.

  11. The Artful Universe Expanded

    Barrow, John D.


    Our love of art, writes John Barrow, is the end product of millions of years of evolution. How we react to a beautiful painting or symphony draws upon instincts laid down long before humans existed. Now, in this enhanced edition of the highly popular The Artful Universe , Barrow further explores the close ties between our aesthetic appreciation and the basic nature of the Universe. Barrow argues that the laws of the Universe have imprinted themselves upon our thoughts and actions in subtle and unexpected ways. Why do we like certain types of art or music? What games and puzzles do we find challenging? Why do so many myths and legends have common elements? In this eclectic and entertaining survey, Barrow answers these questions and more as he explains how the landscape of the Universe has influenced the development of philosophy and mythology, and how millions of years of evolutionary history have fashioned our attraction to certain patterns of sound and color. Barrow casts the story of human creativity and thought in a fascinating light, considering such diverse topics as our instinct for language, the origins and uses of color in nature, why we divide time into intervals as we do, the sources of our appreciation of landscape painting, and whether computer-generated fractal art is really art. Drawing on a wide variety of examples, from the theological questions raised by St. Augustine and C.S. Lewis to the relationship between the pure math of Pythagoras and the music of the Beatles, The Artful Universe Expanded covers new ground and enters a wide-ranging debate about the meaning and significance of the links between art and science.

  12. Multi-Objective Optimization of Mechanical Running Conditions of Large Scale Statically Indeterminate Rotary Kiln

    Hu Xiaoping; Xiao Yougang; Wang Guangbin


    Combined with the second rotary kiln of Alumina Factory in Great Wall Aluminum Company, the mechanics characteristics of statically indeterminate large-scale rotary kiln with variable cross-sections is analyzed. In order to adjusting the runing axis of rotary kiln, taking the force equilibrium of the rollers and the minimum of relative axis deflection as the optimization goal, the multi-objective optimization model of mechanical running conditions of kiln rotary is set up. The mechanical running conditions of the second rotary kiln after multi-objective optimization adjustment are compared with those before adjustment and after routine adjustment. It shows that multi-objective optimization adjustment can make axis as direct as possible and can distribute kiln loads equally.

  13. Biomechanical Evaluation of Plate Versus Lag Screw Only Fixation of Distal Fibula Fractures.

    Misaghi, Amirhossein; Doan, Josh; Bastrom, Tracey; Pennock, Andrew T


    Traditional fixation of unstable Orthopaedic Trauma Association type B/C ankle fractures consists of a lag screw and a lateral or posterolateral neutralization plate. Several studies have demonstrated the clinical success of lag screw only fixation; however, to date no biomechanical comparison of the different constructs has been performed. The purpose of the present study was to evaluate the biomechanical strength of these different constructs. Osteotomies were created in 40 Sawbones(®) distal fibulas and reduced using 1 bicortical 3.5-mm stainless steel lag screw, 2 bicortical 3.5-mm lag screws, 3 bicortical 3.5-mm lag screws, or a single 3.5-mm lag screw coupled with a stainless steel neutralization plate with 3 proximal cortical and 3 distal cancellous screws. The constructs were tested to determine the stiffness in lateral bending and rotation and failure torque. No significant differences in lateral bending or rotational stiffness were detected between the osteotomies fixed with 3 lag screws and a plate. Constructs fixed with 1 lag screw were weaker for both lateral bending and rotational stiffness. Osteotomies fixed with 2 lag screws were weaker in lateral bending only. No significant differences were found in the failure torque. Compared with lag screw only fixation, plate fixation requires larger incisions and increased costs and is more likely to require follow-up surgery. Despite the published clinical success of treating simple Orthopaedic Trauma Association B/C fractures with lag screw only fixation, many surgeons still have concerns about stability. For noncomminuted, long oblique distal fibula fractures, lag screw only fixation techniques offer construct stiffness similar to that of traditional plate and lag screw fixation.

  14. Latarjet Fixation: A Cadaveric Biomechanical Study Evaluating Cortical and Cannulated Screw Fixation.

    Alvi, Hasham M; Monroe, Emily J; Muriuki, Muturi; Verma, Rajat N; Marra, Guido; Saltzman, Matthew D


    Attritional bone loss in patients with recurrent anterior instability has successfully been treated with a bone block procedure such as the Latarjet. It has not been previously demonstrated whether cortical or cancellous screws are superior when used for this procedure. To assess the strength of stainless steel cortical screws versus stainless steel cannulated cancellous screws in the Latarjet procedure. Controlled laboratory study. Ten fresh-frozen matched-pair shoulder specimens were randomized into 2 separate fixation groups: (1) 3.5-mm stainless steel cortical screws and (2) 4.0-mm stainless steel partially threaded cannulated cancellous screws. Shoulder specimens were dissected free of all soft tissue and a 25% glenoid defect was created. The coracoid process was osteomized, placed at the site of the glenoid defect, and fixed in place with 2 parallel screws. All 10 specimens failed by screw cutout. Nine of 10 specimens failed by progressive displacement with an increased number of cycles. One specimen in the 4.0-mm screw group failed by catastrophic failure on initiation of the testing protocol. The 3.5-mm screws had a mean of 274 cycles (SD, ±171 cycles; range, 10-443 cycles) to failure. The 4.0-mm screws had a mean of 135 cycles (SD, ±141 cycles; range, 0-284 cycles) to failure. There was no statistically significant difference between the 2 types of screws for cycles required to cause failure (P = .144). There was no statistically significant difference in energy or cycles to failure when comparing the stainless steel cortical screws versus partially threaded cannulated cancellous screws. Latarjet may be performed using cortical or cancellous screws without a clear advantage of either option.

  15. Subaxial cervical pedicle screw insertion with newly defined entry point and trajectory: accuracy evaluation in cadavers.

    Zheng, Xiujun; Chaudhari, Rahul; Wu, Chunhui; Mehbod, Amir A; Transfeldt, Ensor E


    Successful placement of cervical pedicle screws requires accurate identification of both entry point and trajectory. However, literature has not provided consistent recommendations regarding the direction of pedicle screw insertion and entry point location. The objective of this study was to define a guideline regarding the optimal entry point and trajectory in placing subaxial cervical pedicle screws and to evaluate the screw accuracy in cadaver cervical spines. The guideline for entry point and trajectory for each vertebra was established based on the recently published morphometric data. Six fresh frozen cervical spines (C3-C7) were used. There were two men and four women. After posterior exposure, the entry point was determined and the cortical bone of the entry point was removed using a 2-mm burr. Pilot holes were created with a cervical probe based on the guideline using fluoroscopy. After tapping, 3.5-mm screws with appropriate length were inserted. After screw insertion, every vertebra was dissected and inspected for pedicle breach. The pedicle width, height, pedicle transverse angulation and actual screw insertion angle were measured. A total of 60 pedicle screws were inserted. No statistical difference in pedicle width and height was found between the left and right sides for each level. The overall accuracy of pedicle screws was 83.3%. The remaining 13.3% screws had noncritical breach, and 3.3% had critical breach. The critical breach was not caused by the guideline. There was no statistical difference between the pedicle transverse angulation and the actual screw trajectory created using the guideline. There was statistical difference in pedicle width between the breach and non-breach screws. In conclusion, high success rate of subaxial cervical pedicle screw placement can be achieved using the recently proposed operative guideline and oblique views of fluoroscopy. However, careful preoperative planning and good surgical skills are still required to

  16. Biomechanical Evaluation of Strength and Stiffness of Subtalar Joint Arthrodesis Screw Constructs.

    Jastifer, James R; Alrafeek, Saif; Howard, Peter; Gustafson, Peter A; Coughlin, Michael J


    Subtalar arthrodesis is a common treatment for end-stage subtalar joint arthritis as well as many other clinical problems. The best method of subtalar arthrodesis fixation is unknown. The purpose of this study was to compare the strength of subtalar arthrodesis fixation methods including a single posterior screw (SP), 2 posterior minimally divergent screws (MD) and a 2 screw highly divergent screw (HD) construct for subtalar arthrodesis. A biomechanical study was performed including the three different screw configurations (SP, MD, HD). These surrogate bone specimens were subjected to applied inversion and eversion torques about the subtalar joint axis on a servo-hydraulic load frame. Torsional stiffness of the construct and the maximum torque for each configuration were measured. Additionally, a cadaver study was performed using 5 fresh-frozen cadaver specimens. The perpendicular distance from the divergent screw guide-wire placement was measured from anatomic structures. The HD screw configuration was found to have the highest torsional stiffness in both inversion and eversion, followed by the MD construct and then the SP construct. Similarly, the HD construct had the highest maximum torque versus the MD and SP constructs. All between-group differences were statistically significant (P < .05). The mean distance from key structures to the divergent screw included the sural nerve (13 mm), peroneus brevis tendon (18 mm), tibialis anterior tendon (8 mm), and tibialis posterior tendon (21 mm). This biomechanical and cadaver study supports the use of 2 screws for fixation of subtalar arthrodesis over a single posterior screw. Additionally, we describe a biomechanically superior and potentially safe, alternative 2-screw divergent construct. This study gives biomechanical support for 2 screw, divergent fixation of subtalar arthrodesis or a single over a single screw or two screw minimally divergent construct. © The Author(s) 2015.

  17. Accuracy of robot-assisted pedicle screw placement for adolescent idiopathic scoliosis in the pediatric population.

    Macke, Jeremy J; Woo, Raymund; Varich, Laura


    This is a retrospective review of pedicle screw placement in adolescent idiopathic scoliosis (AIS) patients under 18 years of age who underwent robot-assisted corrective surgery. Our primary objective was to characterize the accuracy of pedicle screw placement with evaluation by computed tomography (CT) after robot-assisted surgery in AIS patients. Screw malposition is the most frequent complication of pedicle screw placement and is more frequent in AIS. Given the potential for serious complications, the need for improved accuracy of screw placement has spurred multiple innovations including robot-assisted guidance devices. No studies to date have evaluated this robot-assisted technique using CT exclusively within the AIS population. Fifty patients were included in the study. All operative procedures were performed at a single institution by a single pediatric orthopedic surgeon. We evaluated the grade of screw breach, the direction of screw breach, and the positioning of the patient for preoperative scan (supine versus prone). Of 662 screws evaluated, 48 screws (7.2 %) demonstrated a breach of greater than 2 mm. With preoperative prone position CT scanning, only 2.4 % of screws were found to have this degree of breach. Medial malposition was found in 3 % of screws, a rate which decreased to 0 % with preoperative prone position scanning. Based on our results, we conclude that the proper use of image-guided robot-assisted surgery can improve the accuracy and safety of thoracic pedicle screw placement in patients with adolescent idiopathic scoliosis. This is the first study to evaluate the accuracy of pedicle screw placement using CT assessment in robot-assisted surgical correction of patients with AIS. In our study, the robot-assisted screw misplacement rate was lower than similarly constructed studies evaluating conventional (non-robot-assisted) procedures. If patients are preoperatively scanned in the prone position, the misplacement rate is further

  18. Influence of processing conditions on the morphology of expanded perlite/polypropylene composites

    Mattausch, H., E-mail:, E-mail:; Laske, S., E-mail:, E-mail:; Holzer, C., E-mail: [Chair of Polymer Processing, Department of Polymer Engineering and Science, Montanuniversitaet Leoben (Austria); Cirar, K., E-mail:, E-mail:; Flachberger, H., E-mail:, E-mail: [Chair of Mineral Processing, Department Mineral Resources and Petroleum Engineering , Montanuniversitaet Leoben (Austria)


    Perlite is an oversaturated, volcanic, glassy rock, which has chemically bound water from 2 to 5 wt%. Upon heating, perlite can be expanded up to 20 times of its original volume. Important applications are in the field of building industry, in refrigeration engineering or the pharmaceutical industry. As mineral filler in polymers, expanded perlite can increase the thermal conductivity, the viscosity and the mechanical properties of polypropylene composites. But there are still many challenges that must be analyzed to reach the full potential of those composites. This research work focuses on the morphology of expanded perlite/polypropylene (PP) compounds and the interactions between filler and polymer. To achieve good performance a homogenous dispersion of the filler in the polymer matrix is needed because the enhancement of the material correlates strongly with the morphology of the composite. Therefore it is necessary to characterize the microstructure of these materials in order to establish adequate structure-process-property relationships. The expanded perlite/PP composites were compounded with a co-rotating twin screw extruder Theysohn TSK 30/40D. For producing the closed cell expanded perlite a new technology, the bublon process, was used. For the material characterization two particles sizes were chosen and the filler content was varied at 5, 10 and 15 wt%. For the analysis of the effects of the screw geometry, two setups have been chosen for the processing of the materials. The produced materials were analyzed by scanning electron microscope (SEM) and tensile testing. The results show a reinforcement effect of the filler and differences in the inner structure of expanded perlite and in the morphology.

  19. Influence of processing conditions on the morphology of expanded perlite/polypropylene composites

    Mattausch, H.; Laske, S.; Cirar, K.; Flachberger, H.; Holzer, C.


    Perlite is an oversaturated, volcanic, glassy rock, which has chemically bound water from 2 to 5 wt%. Upon heating, perlite can be expanded up to 20 times of its original volume. Important applications are in the field of building industry, in refrigeration engineering or the pharmaceutical industry. As mineral filler in polymers, expanded perlite can increase the thermal conductivity, the viscosity and the mechanical properties of polypropylene composites. But there are still many challenges that must be analyzed to reach the full potential of those composites. This research work focuses on the morphology of expanded perlite/polypropylene (PP) compounds and the interactions between filler and polymer. To achieve good performance a homogenous dispersion of the filler in the polymer matrix is needed because the enhancement of the material correlates strongly with the morphology of the composite. Therefore it is necessary to characterize the microstructure of these materials in order to establish adequate structure-process-property relationships. The expanded perlite/PP composites were compounded with a co-rotating twin screw extruder Theysohn TSK 30/40D. For producing the closed cell expanded perlite a new technology, the bublon process, was used. For the material characterization two particles sizes were chosen and the filler content was varied at 5, 10 and 15 wt%. For the analysis of the effects of the screw geometry, two setups have been chosen for the processing of the materials. The produced materials were analyzed by scanning electron microscope (SEM) and tensile testing. The results show a reinforcement effect of the filler and differences in the inner structure of expanded perlite and in the morphology.

  20. A Novel Rotary Piezoelectric Motor Using First Bending Hybrid Transducers

    Yingxiang Liu


    Full Text Available We report a novel rotary piezoelectric motor using bending transducers in this work. Three transducers are used to drive a disk-shaped rotor together by the elliptical movements of their driving tips; these motions are produced by the hybrid of two first bending vibration modes. The proposed piezoelectric transducer has a simple structure as it only contains an aluminum alloy beam and four pieces of PZT plates. Symmetrical structure is the only necessary condition in the design process as it will ensure the resonance frequencies of the two orthogonal first bending modes are equal. Transducers with first bending resonance frequency of about 53 kHz were fabricated and assembled into a rotary motor. The proposed motor exhibits good performance on speed and torque control. Under a working frequency of 53.2 kHz, the maximum no-load speed and the maximum torque of the prototype are tested to be 53.3 rpm and of 27 mN·m.

  1. Predicting the build/drop tendency of rotary drilling assemblies

    Jogl, P.N.; Burgess, T.M.; Bowling, J.P.


    Today, the majority of rotary bottomhole assemblies (BHA's) for directional control are designed through practical experience and trial and error. This approach can produce satisfactory results when a great deal of local experience can be drawn on. It can prove costly, however, during drilling in a new area because of the increased number of trips and correction runs. This paper demonstrates how a BHA model can be used to predict the directional inclination tendencies of rotary assemblies, thus limiting the uncertainty associated with the traditional BHA design techniques. The technique is demonstrated on data from 17 bit runs from three wells on the same platform in the Gulf of Mexico. Predicted tendencies from BHA descriptions alone proved to be accurate (to an error of +-0.1/sup 0//100 ft-0.03/sup 0//10 ml) in more than half the cases. The uncertainty of other predictions appeared to depend on the hole gauge. The distance taken for a BHA to reach a stable build/drop rate after the start of a bit run depends on the length of the BHA. This factor must be taken into account in the prediction of BHA performance.

  2. High Bandwidth Short Stroke Rotary Fast Tool Servo

    Montesanti, R C; Trumper, D L


    This paper presents the design and performance of a new rotary fast tool servo (FTS) capable of developing the 40 g's tool tip acceleration required to follow a 5 micron PV sinusoidal surface at 2 kHz with a planned accuracy of 50 nm, and having a full stroke of 50 micron PV at lower frequencies. Tests with de-rated power supplies have demonstrated a closed-loop unity-gain bandwidth of 2 kHz with 20 g's tool acceleration, and we expect to achieve 40 g's with supplies providing {+-} 16 Amp to the Lorentz force actuator. The use of a fast tool servo with a diamond turning machine for producing non-axisymmetric or textured surfaces on a workpiece is well known. Our new rotary FTS was designed to specifically accommodate fabricating prescription textured surfaces on 5 mm diameter spherical target components for High Energy Density Physics experiments on the National Ignition Facility Laser (NIF).

  3. Thermodynamic and Mechanical Analysis of a Thermomagnetic Rotary Engine

    Fajar, D. M.; Khotimah, S. N.; Khairurrijal


    A heat engine in magnetic system had three thermodynamic coordinates: magnetic intensity ℋ, total magnetization ℳ, and temperature T, where the first two of them are respectively analogous to that of gaseous system: pressure P and volume V. Consequently, Carnot cycle that constitutes the principle of a heat engine in gaseous system is also valid on that in magnetic system. A thermomagnetic rotary engine is one model of it that was designed in the form of a ferromagnetic wheel that can rotates because of magnetization change at Curie temperature. The study is aimed to describe the thermodynamic and mechanical analysis of a thermomagnetic rotary engine and calculate the efficiencies. In thermodynamic view, the ideal processes are isothermal demagnetization, adiabatic demagnetization, isothermal magnetization, and adiabatic magnetization. The values of thermodynamic efficiency depend on temperature difference between hot and cold reservoir. In mechanical view, a rotational work is determined through calculation of moment of inertia and average angular speed. The value of mechanical efficiency is calculated from ratio between rotational work and heat received by system. The study also obtains exergetic efficiency that states the performance quality of the engine.

  4. Optimal Power Flow Control by Rotary Power Flow Controller

    KAZEMI, A.


    Full Text Available This paper presents a new power flow model for rotary power flow controller (RPFC. RPFC injects a series voltage into the transmission line and provides series compensation and phase shifting simultaneously. Therefore, it is able to control the transmission line impedance and the active power flow through it. An RPFC is composed mainly of two rotary phase shifting transformers (RPST and two conventional (series and shunt transformers. Structurally, an RPST consists of two windings (stator and rotor windings. The rotor windings of the two RPSTs are connected in parallel and their stator windings are in series. The injected voltage is proportional to the vector sum of the stator voltages and so its amplitude and angle are affected by the rotor position of the two RPSTs. This paper, describes the steady state operation and single-phase equivalent circuit of the RPFC. Also in this paper, a new power flow model, based on power injection model of flexible ac transmission system (FACTS controllers, suitable for the power flow analysis is introduced. Proposed model is used to solve optimal power flow (OPF problem in IEEE standard test systems incorporating RPFC and the optimal settings and location of the RPFC is determined.

  5. A new rotary ultrasonic motor using longitudinal vibration transducers

    Xiangyu Zhou


    Full Text Available To simplify the design process and improve the motor performance, a rotary ultrasonic motor with rotationally symmetrical structure has been designed, fabricated, and characterized. The stator consists of four connected sandwich-type transducers and eight driving feet. The rotor, a disk, and a disk-shaft are pressed on the two sides of the stator by a nut–spring system. To drive the rotor, two orthogonal longitudinal vibration modes of the stator should be excited. The operating principle of the rotary motor was analyzed by a mathematical model. By using finite element analysis, the feasibility of the operating principle was validated, and the optimal structure dimensions of stator were determined in order to improve the driving teeth motion. The overall dimensions of the prototype stator are 30 mm (width × 30 mm (width × 50 mm (length. Driven by alternating current signals with the driving frequency of 50.93 kHz and voltage 300 VP-P, the motor gave a maximal no-load speed of 157.9 r/min and a maximal output torque of 11.76 mN m.

  6. Miniature electrically tunable rotary dual-focus lenses

    Zou, Yongchao; Zhang, Wei; Lin, Tong; Chau, Fook Siong; Zhou, Guangya


    The emerging dual-focus lenses are drawing increasing attention recently due to their wide applications in both academia and industries, including laser cutting systems, microscopy systems, and interferometer-based surface profilers. In this paper, a miniature electrically tunable rotary dual-focus lens is developed. Such a lens consists of two optical elements, each having an optical flat surface and one freeform surface. The two freeform surfaces are initialized with the governing equation Ar2θ (A is the constant to be determined, r and θ denote the radii and angles in the polar coordinate system) and then optimized by ray tracing technique with additional Zernike polynomial terms for aberration correction. The freeform surfaces are achieved by a single-point diamond turning technique and then a PDMS-based replication process is utilized to materialize the final lens elements. To drive the two coaxial elements to rotate independently, two MEMS thermal rotary actuators are developed and fabricated by a standard MUMPs process. The experimental results show that the MEMS thermal actuator provides a maximum rotation angle of about 8.2 degrees with an input DC voltage of 6.5 V, leading to a wide tuning range for both the two focal lengths of the lens. Specifically, one focal length can be tuned from about 30 mm to 20 mm while the other one can be adjusted from about 30 mm to 60 mm.

  7. 'n Beoordeling van die Rotarier-bewe^in.u

    Deon Kempff


    Full Text Available Heeds vir ’n paar maande hel Harris met enkele van sy jong vriendegepraat oor die moontlikheid 0111 'n soort kluh of vereniging te stig ommekaar beter te leer ken en mekaar te help. Non ii vier van 1 mile, Harris,Schiele (kole-handelaar, Loehr I myn-ingenieur en Shorey (snyer,saam in ’ 11 kantoor in hierdie stad. Die saak word bespreek en daarword besluit 0111 ’11 klul> te stig. Daarna word meer samekomste gehou,telkens in ’ 11 ander kantoor sodat daar afwisseling of rotasie van vergaderplekis. So ontstaan die naam Rotary. As embleem word spoedig gekies"n wawiel-met-speke. wat later ( 19231 gewysig is na die bekerulc (masjien-/■«i-motief. Die ledetal word gestadig meer en selfs in 1934 is die Rotariërklubvan Chicago die grootsle enkele kluh (meer as 000 lede, juis0 0 k onulat in hierdie stad nie meerdere klnbs gestig word soos watelders gebeur nie.

  8. Modeling and Analysis of A Rotary Direct Drive Servovalve

    YU Jue; ZHUANG Jian; YU Dehong


    Direct drive servovalves are mostly restricted to low flow rate and low bandwidth applications due to the considerable flow forces. Current studies mainly focus on enhancing the driving force, which in turn is limited to the development of the magnetic material. Aiming at reducing the flow forces, a novel rotary direct drive servovalve(RDDV) is introduced in this paper. This RDDV servovalve is designed in a rotating structure and its axially symmetric spool rotates within a certain angle range in the valve chamber. The servovalve orifices are formed by the matching between the square wave shaped land on the spool and the rectangular ports on the sleeve. In order to study the RDDV servovalve performance, flow rate model and mechanical model are established, wherein flow rates and flow induced torques at different spool rotation angles or spool radiuses are obtained. The model analysis shows that the driving torque can be alleviated due to the proposed valve structure. Computational fluid dynamics(CFD) analysis using ANSYS/FLUENT is applied to evaluate and validate the theoretical analysis. In addition, experiments on the flow rate and the mechanical characteristic of the RDDV servovalve are carried out. Both simulation and experimental results conform to the results of the theoretical model analysis, which proves that this novel and innovative structure for direct drive servovalves can reduce the flow force on the spool and improve valve frequency response characteristics. This research proposes a novel rotary direct drive servovalve, which can reduce the flow forces effectively.


    Staff Association


    We have been informed about the Rotary day at the United Nations office in Geneva. Join us on November 10th & 11th, 2017 at the United Nations office Avenue de la Paix 8-14 1211 Geneva, Switzerland   PEACE: MAKING A DIFFERENCE! Conflict and violence displace millions of people each year. Half of those killed in conflict are children, and 90 percent are civilians. We, Rotarians, refuse conflict as a way of life. But how can we contribute to Peace? And what about you? Are you keen on meeting exceptional individuals and exchanging ideas to move forward? Would you like to network and collaborate with Rotarians, Government Representatives, International Civil Servants, Representatives of Nongovernmental Organizations and Liberal Professions, Businessmen/women, and Students to make a difference in Peace? In November 2017, come to Geneva, get involved, and formulate recommendations to the international community. Together, we’ll celebrate Rotary&a...

  10. Electric Field Driven Torque in Biological Rotary Motors

    Miller,, John H; Maric, Sladjana; Infante, Hans L; Claycomb, James R


    Ion driven rotary motors, such as Fo-ATP synthase (Fo) and the bacterial flagellar motor, act much like a battery-powered electric motor. They convert energy from ions as they move from high to low potential across a membrane into torque and rotary motion. Here we propose a mechanism whereby electric fields, emanating from channels in one or more stators, act on asymmetric charge distributions due to protonated and deprotonated sites in the rotor and drive it to rotate. The model predicts an ideal scaling law between torque and ion motive force, which can be hindered by mitochondrial mutations. The rotor of Fo drives the gamma-subunit to rotate within the ATP-producing complex (F1), working against an opposing torque that rises and falls periodically with angular position. Drawing an analogy with Brownian motion of a particle in a tilted washboard potential, we compute the highly nonlinear ATP production rate vs. proton motive force (pmf), showing a minimum pmf needed to drive ATP production with important me...

  11. A rotary arc furnace for aluminum dross processing

    Drouet, M.G.; Meunier, J.; Laflamme, C.B.; Handfield, M.D.; Biscaro, A.; Lemire, C. [Hydro-Quebec, Shawinigan, Quebec (Canada)


    Dross, a major by-product of all processes involving molten aluminum, forms at the surface of the molten metal as the latter reacts with the furnace atmosphere. It generally represents 1 to 5 wt% of the melt, depending on the process, and contains on average about 50% free aluminum dispersed in an oxide layer. Since aluminum production is highly energy-intensive, dross recycling is very attractive from both the energy and the economic standpoints. The conventional recycling process using salt rotary furnaces is thermally inefficient and environmentally non-acceptable because of the production of salt slags. Hydro-Quebec has developed and patented a new salt-free technology using a rotary furnace heated by an electric arc between two graphite electrodes, called DROSCAR{reg_sign}. A 600-kW pilot plant in operation at LTEE is in use to demonstrate the process. This process provides aluminum recovery rates over 90%, using a highly energy efficient, environmentally sound production method. In 1994, 400 tonnes of aluminum dross were treated in this facility and several tests on various types of dross have also been conducted in early 1995. A report on the results will be presented.

  12. A rotary arc furnace for aluminum dross processing

    Drouet, M.G.; Meunier, J.; Laflamme, C.B.; Handfield, M.D.; Biscaro, A.; Lemire, C. [Hydro-Quebec, Shawinigan, Quebec (Canada)


    Dross, a major by-product of all processes involving molten aluminum, forms at the surface of the molten metal as the latter reacts with the furnace atmosphere. It generally represents 1 to 5 wt% of the melt, depending on the process, and contains on average about 50% free aluminum dispersed in an oxide layer. Since aluminum production is highly energy-intensive, dross recycling is very attractive from both the energy and the economic standpoints. The conventional recycling process using salt rotary furnaces is thermally inefficient and environmentally unacceptable because of the salt slags produced. Hydro-Quebec has developed and patented a new salt-free technology using a rotary furnace heated by an electric arc between two graphite electrodes, called DROSCAR{reg_sign}. A 600-kW pilot plant in operation at LTEE is in use to demonstrate the process. This process provides aluminum recovery rates for over 90%, using a highly energy efficient, environmentally sound production method. In 1994, 400 tons of aluminum dross were treated in this facility and several tests on various types of dross have also been conducted in early 1995. A report on the results will be presented.

  13. Accuracy and safety of free-hand pedicle screw fixation in age less than 10 years

    Hyoung Yeon Seo


    Full Text Available Background: Pedicle screws are being used commonly in the treatment of various spinal disorders. However, use of pedicle screws in the pediatric population is not routinely recommended because of the risk of complications. The present study was to evaluate the safety of pedicle screws placed in children aged less than 10 years with spinal deformities and to determine the accuracy and complication (early and late of pedicle screw placement using the postoperative computed tomography (CT scans. Materials and Methods: Thirty one patients (11 males and 20 females who underwent 261 pedicle screw fixations (177 in thoracic vertebrae and 84 in lumbar vertebrae for a variety of pediatric spinal deformities at a single institution were included in the study. The average age of patients was 7 years and 10 months. These patients underwent postoperative CT scan which was assessed by two independent observers (spine surgeons not involved in the treatment. Results: Breach rate was 5.4% (14/261 screws for all pedicles. Of the 177 screws placed in the thoracic spine, 13 (7.3% had breached the pedicle, that is 92.7% of the screws were accurately placed within pedicles. Seven screws (4% had breached the medial pedicle wall, 4 screws (2.3% had breached the lateral pedicle wall and 2 screws (1.1% had breached the superior or inferior pedicle wall respectively. Of the 84 screws placed in the lumbar spine, 83 (98.8% screws were accurately placed within the pedicle. Only 1 screw (1.2% was found to be laterally displaced. In addition, the breach rate was found to be 4.2% (11/261 screws with respect to the vertebral bodies. No neurological, vascular or visceral complications were encountered. Conclusions: The accuracy of pedicle screw placement in pedicles and vertebral bodies were 94.6% and 95.8% respectively and there was no complication related to screw placement noted until the last followup. These results suggest that free-hand pedicle screw fixation can be safely

  14. Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation

    Katonis Pavlos G


    Full Text Available Abstract Background Lag screw cut-out failure following fixation of unstable intertrochanteric fractures in osteoporotic bone remains an unsolved challenge. This study tested if resistance to cut-out failure can be improved by using a dual lag screw implant in place of a single lag screw implant. Migration behavior and cut-out resistance of a single and a dual lag screw implant were comparatively evaluated in surrogate specimens using an established laboratory model of hip screw cut-out failure. Methods Five dual lag screw implants (Endovis, Citieffe and five single lag screw implants (DHS, Synthes were tested in the Hip Implant Performance Simulator (HIPS of the Legacy Biomechanics Laboratory. This model simulated osteoporotic bone, an unstable fracture, and biaxial rocking motion representative of hip loading during normal gait. All constructs were loaded up to 20,000 cycles of 1.45 kN peak magnitude under biaxial rocking motion. The migration kinematics was continuously monitored with 6-degrees of freedom motion tracking system and the number of cycles to implant cut-out was recorded. Results The dual lag screw implant exhibited significantly less migration and sustained more loading cycles in comparison to the DHS single lag screw. All DHS constructs failed before 20,000 cycles, on average at 6,638 ± 2,837 cycles either by cut-out or permanent screw bending. At failure, DHS constructs exhibited 10.8 ± 2.3° varus collapse and 15.5 ± 9.5° rotation around the lag screw axis. Four out of five dual screws constructs sustained 20,000 loading cycles. One dual screw specimens sustained cut-out by medial migration of the distal screw after 10,054 cycles. At test end, varus collapse and neck rotation in dual screws implants advanced to 3.7 ± 1.7° and 1.6 ± 1.0°, respectively. Conclusion The single and double lag screw implants demonstrated a significantly different migration resistance in surrogate specimens under gait loading simulation with


    Marchenko A. Y.


    Full Text Available The article reveals a possibility of using equipment based on relative screw and combined drums for mixing of bulks. Change of relative positioning of flat elements of sidewalls of internal surfaces in relative screw drums allows operating the difficult and spatial movement of streams of bulks. In relative screw drums we have developed effective processes of mixing and sets of the equipment, which are characterized by that fact the difficult and spatial screw movement taking place in relative screw drums is dismembered on rather simple, in the kinematic relation, in the movements. The difficult and spatial screw movement with a big amplitude of 15-1000 mm and more, in the offered equipment constructions on the basis of relative screw or combined drums, is reported to bulks by elements of the relative screw or combined drums of various parameters and configurations which becomes complicated also screw lines on perimeter of a relative screw drum with various number of calling and the directions from each other or rounds of the springs fixed in the relative combined drums

  16. Cytotoxicity of a new antimicrobial coating for surgical screws: an in vivo study

    Güzel, Yunus; Elmadag, Mehmet; Uzer, Gokcer; Yıldız, Fatih; Bilsel, Kerem; Tuncay, İbrahim


    INTRODUCTION The risk of surgery-related infection is a persistent problem in orthopaedics and infections involving implants are particularly difficult to treat. This study explored the responses of bone and soft tissue to antimicrobial-coated screws. We investigated whether such screws, which have never been used to fix bony tissues, would result in a cytotoxic effect. We hypothesised that the coated screws would not be toxic to the bone and that the likelihood of infection would be reduced since bacteria are not able to grow on these screws. METHODS Titanium screws were inserted into the left supracondylar femoral regions of 16 rabbits. The screws were either uncoated (control group, n = 8) or coated with a polyvinylpyrrolidone-polyurethane interpolymer with tertiary amine functional groups (experimental group, n = 8). At Week 6, histological samples were obtained and examined. The presence of necrosis, fibrosis and inflammation in the bony tissue and the tissue surrounding the screws was recorded. RESULTS Live, cellular bone marrow was present in all the rabbits from the experimental group, but was replaced with connective tissue in four rabbits from the control group. Eight rabbits from the control group and two rabbits from the experimental group had necrosis in fatty bone marrow. Inflammation was observed in one rabbit from the experimental group and five rabbits from the control group. CONCLUSION Titanium surgical screws coated with polyvinylpyrrolidone-polyurethane interpolymer were associated with less necrosis than standard uncoated screws. The coated screws were also not associated with any cytotoxic side effect. PMID:26805670

  17. A novel approach to navigated implantation of S-2 alar iliac screws using inertial measurement units.

    Jost, Gregory F; Walti, Jonas; Mariani, Luigi; Cattin, Philippe


    The authors report on a novel method of intraoperative navigation with inertial measurement units (IMUs) for implantation of S-2 alar iliac (S2AI) screws in sacropelvic fixation of the human spine and its application in cadaveric specimens. Screw trajectories were planned on a multiplanar reconstruction of the preoperative CT scan. The pedicle finder and screwdriver were equipped with IMUs to guide the axial and sagittal tilt angles of the planned trajectory, and navigation software was developed. The entry points were chosen according to anatomical landmarks on the exposed spine. After referencing, the sagittal and axial orientation of the pedicle finder and screwdriver were wirelessly monitored on a computer screen and aligned with the preoperatively planned tilt angles to implant the S2AI screws. The technique was performed without any intraoperative imaging. Screw positions were analyzed on postoperative CT scans. Seventeen of 18 screws showed a good S2AI screw trajectory. Compared with the postoperatively measured tilt angles of the S2AI screws, the IMU readings on the screwdriver were within an axial plane deviation of 0° to 5° in 15 (83%) and 6° to 10° in 2 (11%) of the screws and within a sagittal plane deviation of 0° to 5° in 15 (83%) and 6° to 10° in 3 (17%) of the screws. IMU-based intraoperative navigation may facilitate accurate placement of S2AI screws.

  18. SU-E-T-609: Perturbation Effects of Pedicle Screws On Radiotherapy Dose Distributions

    Bar-Deroma, R; Borzov, E; Nevelsky, A [Rambam Medical Center, Haifa (Israel)


    Purpose: Radiation therapy in conjunction with surgical implant fixation is a common combined treatment in case of bone metastases. However, metal implants generally used in orthopedic implants perturb radiation dose distributions. Carbon-Fiber Reinforced (CFR) PEEK material has been recently introduced for production of intramedullary screws and plates. Gold powder can be added to the CFR-PEEK material in order to enhance visibility of the screws during intraoperative imaging procedures. In this work, we investigated the perturbation effects of the pedicle screws made of CFR-PEEK, CFR-PEEK with added gold powder (CFR-PEEK-AU) and Titanium (Ti) on radiotherapy dose distributions. Methods: Monte Carlo (MC) simulations were performed using the EGSnrc code package for 6MV beams with 10×10 fields at SSD=100cm. By means of MC simulations, dose distributions around titanium, CFR- PEEK and CFR-PEEK-AU screws (manufactured by Carbo-Fix Orthopedics LTD, Israel) placed in a water phantom were calculated. The screw axis was either parallel or perpendicular to the beam axis. Dose perturbation (relative to dose in homogeneous water phantom) was assessed. Results: Maximum overdose due to backscatter was 10% for the Ti screws, 5% for the CFR-PEEK-AU screws and effectively zero for the CFR-PEEK screws. Maximum underdose due to attenuation was 25% for the Ti screws, 15% for the CFR-PEEK-AU screws and 5% for the CFR-PEEK screws. Conclusion: Titanium screws introduce the largest distortion on the radiation dose distribution. The gold powder added to the CFR-PEEK material improves visibility at the cost of increased dose perturbation. CFR-PEEK screws caused minimal alteration on the dose distribution. This can decrease possible over and underdose of adjacent tissue and thus favorably influence treatment efficiency. The use of such implants has potential clinical advantage in the treatment of neoplastic bone disease.

  19. Determination of Screw and Nail Withdrawal Resistance of Some Important Wood Species

    Alper Aytekin


    Full Text Available In this study, screw and nail withdrawal resistance of fir (Abies nordmanniana, oak (Quercus robur L. black pine (Pinus nigra Arnold and Stone pine (Pinus pinea L. wood were determined and compared. The data represent the testing of withdrawal resistance of three types of screws as smart, serrated and conventional and common nails. The specimens were prepared according to TS 6094 standards. The dimensions of the specimens were 5x5x15cm and for all of the directions. Moreover, the specimens were conditioned at ambient room temperature and 65±2% relative humidity. The screws and nails were installed according to ASTM-D 1761 standards. Nail dimensions were 2.5mm diameter and 50 mm length, conventional screws were 4x50mm, serrated screws were 4x45mm and smart screws were 4x50mm. Results show that the maximum screw withdrawal resistance value was found in Stone pine for the serrated screw. There were no significant differences between Stone pine and oak regarding screw withdrawal resistance values. Conventional screw yielded the maximum screw withdrawal resistance value in oak, followed by Stone pine, black pine and fir. Oak wood showed the maximum screw withdrawal resistance value for the smart screw, followed by Stone pine, black pine, and fir. Oak wood showed higher nail withdrawal resistances than softwood species. It was also determined that oak shows the maximum nail withdrawal resistance in all types. The nail withdrawal resistances at the longitudinal direction are lower with respect to radial and tangential directions.

  20. Analysis of mechanical preparations in extracted teeth using ProTaper rotary instruments: value of the safety quotient.

    Blum, J Y; Machtou, P; Ruddle, C; Micallef, J P


    small flexible stainless steel hand files to create or verify that within any portion of a root canal there is sufficient space for rotary instruments to follow. When there is a confirmed smooth, reproducible glide path, then a "secured" space exists to safely guide the more flexible terminal extent of a rotary NiTi file. Endogrammes provide an innovative approach to the analysis of mechanical preparations and suggest that the ProTaper shaping files are best used with lateral forces to decrease the coronal screwing effect. The ProTaper finishing files should be used with slow penetration and be introduced only into canals that have a confirmed smooth and reproducible glide path. When any part of the overall length of a canal has been secured, then the number of instruments, the time spent utilizing each instrument, and the overall time progressing through a sequence of instruments to shape this region of the canal is reduced.