WorldWideScience

Sample records for root-end filling material

  1. Biocompatibility of root-end filling materials: recent update

    Directory of Open Access Journals (Sweden)

    Payal Saxena

    2013-08-01

    Full Text Available The purpose of a root-end filling is to establish a seal between the root canal space and the periradicular tissues. As root-end filling materials come into contact with periradicular tissues, knowledge of the tissue response is crucial. Almost every available dental restorative material has been suggested as the root-end material of choice at a certain point in the past. This literature review on root-end filling materials will evaluate and comparatively analyse the biocompatibility and tissue response to these products, with primary focus on newly introduced materials.

  2. Portland cement versus MTA as a root-end filling material. A pilot study.

    Science.gov (United States)

    da Silva, Sérgio Ribeiro; da Silva Neto, José Dias; Veiga, Daniela Francescato; Schnaider, Taylor Brandão; Ferreira, Lydia Masako

    2015-02-01

    To assess periradicular lesions clinically and by computed tomography (CT) after endodontic surgery using either Portland cement or mineral trioxide aggregate (MTA) as a root-end filling material. Three patients diagnosed with periradicular lesions by cone-beam CT underwent endodontic surgery with root-end filling. Patient A was treated with MTA as the root-end filling material, patient B was treated with Portland cement and patient C had two teeth treated, one with MTA and the other with Portland cement. Six months after surgery, the patients were assessed clinically and by CT scan and the obtained results were compared. Periradicular tissue regeneration was observed in all cases, with no significant differences in bone formation when comparing the use of MTA and Portland cement as root-end filling materials. Both mineral trioxide aggregate and Portland cement were successful in the treatment of periradicular lesions.

  3. Characteristics of novel root-end filling material using epoxy resin and Portland cement.

    Science.gov (United States)

    Lee, Sang-Jin; Chung, Jin; Na, Hee-Sam; Park, Eun-Joo; Jeon, Hyo-Jin; Kim, Hyeon-Cheol

    2013-04-01

    The aim of this study was to evaluate the physical properties and cytotoxicity of a novel root-end filling material (EPC) which is made from epoxy resin and Portland cement as a mineral trioxide aggregate (MTA) substitute. EPC, developed as a root-end filling material, was compared with MTA and a mixture of AH Plus sealer and MTA (AMTA) with regard to the setting time, radio-opacity, and microleakage. Setting times were evaluated using Vicat apparatus. Digital radiographs were taken to evaluate the aluminium equivalent radio-opacity using an aluminium step wedge. Extracted single-rooted teeth were used for leakage test using methylene blue dye. After canal shaping and obturation, the apical 3-mm root was resected, and a root-end cavity with a depth of 3 mm was prepared. The root-end cavities were filled with MTA, AMTA, and EPC for 15 specimens in each of three groups. After setting in humid conditions for 24 h, the specimens were tested for apical leakage. For evaluation of the biocompatibility of EPC, cell (human gingival fibroblast) viability was compared for MTA and Portland cement by MTT assay, and cell morphological changes were compared for MTA and AH Plus by fluorescence microscopy using DAPI and F-actin staining. The setting time, radio-opacity, and microleakage were compared using one-way ANOVA and Scheffe's post hoc comparison, and the cytotoxicity was compared using the nonparametric Kruskal-Wallis rank sum test. Statistical significance was set at 95%. EPC had a shorter setting time and less microleakage compared with MTA (p Portland cement, was found to be a useful material for root-end filling, with favourable radio-opacity, short setting time, low microleakage, and clinically acceptable low cytotoxicity. The novel root-end filling material would be a potentially useful material for a surgical endodontic procedure with favourable properties.

  4. Comparison of the sealing ability of mineral trioxide aggregate and Portland cement used as root-end filling materials.

    Science.gov (United States)

    Shahi, Shahriar; Yavari, Hamid R; Rahimi, Saeed; Eskandarinezhad, Mahsa; Shakouei, Sahar; Unchi, Mahsa

    2011-12-01

    Inadequate apical seal is the major cause of surgical endodontic failure. The root-end filling material used should prevent egress of potential contaminants into periapical tissue. The purpose of this study was to compare the sealing ability of four root-end filling materials: white mineral trioxide aggregate (MTA), gray MTA, white Portland cement (PC) and gray PC by dye leakage test. Ninety-six human single-rooted teeth were instrumented, and obturated with gutta-percha. After resecting the apex, an apical cavity was prepared. The teeth were randomly divided into four experimental groups (A: white MTA, B: gray MTA, C: white PC and D: gray PC; n = 20) and two control groups (positive and negative control groups; n = 8). Root-end cavities in the experimental groups were filled with the experimental materials. The teeth were exposed to Indian ink for 72 hours. The extent of dye penetration was measured with a stereomicroscope at 16× magnification. The negative controls showed no dye penetration and dye penetration was seen in the entire root-end cavity of positive controls. However, there was no statistically significant difference among the four experimental groups (P > 0.05). All retrograde filling materials tested in this study showed the same microleakage in vitro. Given the low cost and apparently similar sealing ability of PC, PC could be considered as a substitute for MTA as a root-end filling material.

  5. Sealing ability of MTA, CPM, and MBPc as root-end filling materials: a bacterial leakage study.

    Science.gov (United States)

    Medeiros, Paulo Leal; Bernardineli, Norberti; Cavenago, Bruno Cavalini; Torres, Sérgio Aparecido; Duarte, Marco Antonio Hungaro; Bramante, Clovis Monteiro; Marciano, Marina Angélica

    2016-04-01

    Objectives To evaluate the sealing ability of three root-end filling materials (white MTA, CPM, and MBPc) using an Enterococcus faecalis leakage model. Material and Methods Seventy single-root extracted human teeth were instrumented and root-ends were resected to prepare 3 mm depth cavities. Root-end preparations were filled with white MTA, CPM, and MBPc cements. Enterococcus faecalis was coronally introduced and the apical portion was immersed in BHI culture medium with phenol red indicator. The bacterial leakage was monitored every 24 h for 4 weeks. The statistical analysis was performed using the Wilcoxon-Gehan test (pCPM and the other groups. Conclusions The epoxy resin-based cement MBPc had lower bacterial leakage compared with the calcium silicate-based cements MTA and CPM.

  6. Evaluation of Root-End Resections Performed by Er, Cr: YSGG Laser with and without Placement of a Root-End Filling Material

    Directory of Open Access Journals (Sweden)

    John Sullivan

    2009-01-01

    Full Text Available Microleakage following root-end resections has a direct influence on the outcome of surgical endodontic procedures. This study compared the microleakage after root-end resections performed by the Er, Cr: YSGG laser or carbide burs with or without the placement of MTA, and evaluated the presence of microcracks and gaps at the interface of GP/MTA and the canal walls. Ninety single-rooted teeth were instrumented, obturated with GP and AH-Plus sealer, and divided into 3 experimental groups: (I root-end resections were performed with the laser and G6 tips (parameters: 4.5 w, 30 pps, 20% water and 50% air; (II Lindeman burs were used, without the placement of MTA; (III the burs were used followed by root-end fillings with MTA, and one control (IV of five unobturated roots resected with the burs. The samples were prepared for microleakage (=20 and SEM (=10 analysis. They were immersed in 1% methylene blue, decalcified, cleared, and evaluated for dye penetration (mm2 with the ImageJ software. Epoxy-resin replicas of the root-ends were analyzed by SEM for gaps (m2 and microcracks. Microleakage results were 0.518±1.059, 0.172±0.223, and 0.158±0.253, for the laser (I, no root-end filling (II, and MTA (III samples, respectively, (ANOVA =.02. The laser (7831.7±2329.2 and no root-end filling (7137.3±1400.7 samples presented gaps. Whereas, none was found in the MTA (ANOVA =.002. Microcracks were not observed. The MTA group demonstrated statistically less leakage and better adaptation to the canal walls when compared to the other groups. There was no correlation between the size of the gaps and the degree of microleakage.

  7. Comparison of antibacterial activities of root-end filling materials by an agar diffusion assay and Alamar blue assay

    Directory of Open Access Journals (Sweden)

    Tsui-Hsien Huang

    2012-12-01

    Conclusion: We concluded that both the agar diffusion test and Alamar blue assay gave comparable findings of assessing the antimicrobial activity present in root-end filling materials. No antimicrobial activity was detected for mineral trioxide aggregate, calcium silicate cement, or amalgam after coming into contact with S. mutans, S. sanguinis and E. coli. IRM showed high antimicrobial activity against both S. sanguinis and E. coli.

  8. Healing process following application of set or fresh mineral trioxide aggregate as a root-end filling material.

    Science.gov (United States)

    Habibi, Mehdi; Ghoddusi, Jamileh; Habibi, Ataollah; Mohtasham, Nooshin

    2011-01-01

    An unsuccessful attempt to reach the apical area or to place the retrograde material is a major difficulty in periradicular surgery. The aim of this study was to compare the histological evaluation of the healing process following an orthograde versus a retrograde application of mineral trioxide aggregate (MTA) as a root-end filling material during apical surgery on cats' teeth in order to find out whether orthograde placement of MTA before surgery can be used instead of retrograde placement during surgery. In this experimental study, 24 canine teeth in 12 mature and healthy cats were filled with either MTA or gutta-percha in an orthograde manner. Two weeks later, the teeth with MTA were surgically exposed and resected to the set-MTA within the canals. The teeth previously filled by gutta-percha were also surgically exposed, and retrograde cavities were prepared at the root ends and filled with fresh-MTA. After 8 weeks, the animals were euthanized by vital perfusion. Six-micron histological slices were prepared from samples, stained by Hematoxylin & Eosin, and histologically studied by means of a light microscope. The collected data was analyzed by the Chi-square and the T-test. One of the samples in the fresh-MTA group was omitted during processing because of inappropriate sectioning. In the set-MTA group, 5 out of 12 showed chronic abscess, while in the fresh-MTA group, 2 out of 11 were discovered to have chronic abscess; however, no significant difference was observed (P>.05). Hard tissue healing (cementum, bone, cementum + bone formation) in the set-MTA and fresh-MTA groups were 7 out of 12 and 9 out of 11, respectively. While healing seemed more likely to occur in the fresh-MTA group, the difference was statistically insignificant (P>.05). The magnitude of bone, cementum, or bone and cementum formation showed slight differences between the two groups; however, the figures failed to show any marked differences (P>.05). Orthograde placement of MTA could be used

  9. Microbial leakage of MTA, Portland cement, Sealapex and zinc oxide-eugenol as root-end filling materials.

    Science.gov (United States)

    Estrela, Carlos; Estrada-Bernabé, Pedro-Felício; de Almeida-Decurcio, Daniel; Almeida-Silva, Julio; Rodrigues-Araújo-Estrela, Cyntia; Poli-Figueiredo, José-Antonio

    2011-05-01

    The aim of this study was to compare the microbial leakage of mineral trioxide aggregate (MTA), Portland cement (PC), Sealapex and zinc oxide-eugenol (ZOE) as root-end filling materials. An in vitro microbial leakage test (MLT) with a split chamber was used in this study. A mixture of facultative bacteria and one yeast (S. aureus+E. faecalis+P. aeruginosa+B. subtilis+C. albicans) was placed in the upper chamber and it could only reach the lower chamber containing Brain Heart Infusion broth by way of leakage through the root-end filling. Microbial leakage was observed daily for 60 days. Sixty maxillary anterior human teeth were randomly assigned to different groups--MTA and PC (gray and white), Sealapex+zinc oxide and ZOE, control groups and subgroups to evaluate the influence of EDTA for smear layer removal. These materials were further evaluated by an agar diffusion test (ADT) to verify their antimicrobial efficacy. Data were analyzed statistically by Kruskal-Wallis and Mann-Whitney test. In the MLT, Sealapex+zinc oxide and ZOE did not show evidence of microbial leakage over the 60-day experimental period. The other materials showed leakage from the 15th day. The presence of smear layer influenced microbial leakage. Microbial inhibition zones were not observed in all samples tested by ADT. Sealapex+zinc oxide and ZOE did not show microbial leakage over the experimental period, whereas it was verified within 15 to 45 days in MTA and Portland cement.

  10. Evaluation of physicochemical properties of root-end filling materials using conventional and Micro-CT tests

    Directory of Open Access Journals (Sweden)

    Fernanda Ferrari Esteves TORRES

    Full Text Available Abstract Objective To evaluate solubility, dimensional stability, filling ability and volumetric change of root-end filling materials using conventional tests and new Micro-CT-based methods. Material and Methods Solubility (loss of mass after 7 and 30 days, and dimensional stability (in mm were evaluated in accordance with Carvalho-Junior, et al. 7 (2007. The filling ability and volumetric change (in mm3 were evaluated by Micro-CT (Bruker-MicroCT, Kontich, Belgium using resin models with cavities 3 mm deep and 1 mm in diameter. The cavities were filled with materials to evaluate filling ability, and then scanned by Micro-CT. After 7 and 30 days immersed in distilled water, the filled cavities were scanned again to evaluate the volumetric change. MTA Angelus (MTA, Biodentine (BIO and zinc oxide-eugenol cement (ZOE were evaluated. Data were submitted to analysis of variance (ANOVA and Tukey's test with 5% significance level. Results The results suggested correlated or complementary data between the proposed tests. At 7 days, BIO showed higher solubility and at 30 days, showed higher volumetric change in comparison with MTA (p0.05 at 7 days. At 30 days, they presented similar solubility. BIO and MTA showed higher dimensional stability than ZOE (p<0.05. ZOE and BIO showed higher filling ability (p<0.05. Conclusions ZOE presented a higher dimensional change, and BIO had greater solubility after 7 days. BIO presented filling ability and dimensional stability, but greater volumetric change than MTA after 30 days. Micro-CT can provide important data on the physicochemical properties of materials complementing conventional tests.

  11. Effect of ultrasonic agitation on push-out bond strength and adaptation of root-end filling materials.

    Science.gov (United States)

    Alcalde, Murilo Priori; Vivan, Rodrigo Ricci; Marciano, Marina Angélica; Duque, Jussaro Alves; Fernandes, Samuel Lucas; Rosseto, Mariana Bailo; Duarte, Marco Antonio Hungaro

    2018-05-01

    This study evaluated the effect of ultrasonic agitation of mineral trioxide aggregate (MTA), calcium silicate-based cement (CSC), and Sealer 26 (S26) on adaptation at the cement/dentin interface and push-out bond strength. Sixty maxillary canines were divided into 6 groups ( n = 10): MTA, S26, and CSC, with or without ultrasonic activation (US). After obturation, the apical portions of the teeth were sectioned, and retrograde cavities were prepared and filled with cement by hand condensation. In the US groups, the cement was activated for 60 seconds: 30 seconds in the mesio-distal direction and 30 seconds in the buccal-lingual direction, using a mini Irrisonic insert coupled with the ultrasound transducer. After the materials set, 1.5-mm thick sections were obtained from the apexes. The presence of gaps and the bond between cement and dentin were analyzed using low-vacuum scanning electron microscopy. Push-out bond strength was measured using a universal testing machine. Ultrasonic agitation increased the interfacial adaptation of the cements. The S26 US group showed a higher adaptation value than MTA ( p < 0.05). US improved the push-out bond strength for all the cements ( p < 0.05). The US of retrograde filling cements enhanced the bond to the dentin wall of the root-end filling materials tested.

  12. Hydration characteristics of zirconium oxide replaced Portland cement for use as a root-end filling material.

    Science.gov (United States)

    Camilleri, J; Cutajar, A; Mallia, B

    2011-08-01

    Zirconium oxide can be added to dental materials rendering them sufficiently radiopaque. It can thus be used to replace the bismuth oxide in mineral trioxide aggregate (MTA). Replacement of Portland cement with 30% zirconium oxide mixed at a water/cement ratio of 0.3 resulted in a material with adequate physical properties. This study aimed at investigating the microstructure, pH and leaching in physiological solution of Portland cement replaced zirconium oxide at either water-powder or water-cement ratios of 0.3 for use as a root-end filling material. The hydration characteristics of the materials which exhibited optimal behavior were evaluated. Portland cement replaced by zirconium oxide in varying amounts ranging from 0 to 50% in increments of 10 was prepared and divided into two sets. One set was prepared at a constant water/cement ratio while the other set at a constant water/powder ratio of 0.3. Portland cement and MTA were used as controls. The materials were analyzed under the scanning electron microscope (SEM) and the hydration products were determined. X-ray energy dispersive analysis (EDX) was used to analyze the elemental composition of the hydration products. The pH and the amount of leachate in Hank's balanced salt solution (HBSS) were evaluated. A material that had optimal properties that satisfied set criteria and could replace MTA was selected. The microstructure of the prototype material and Portland cement used as a control was assessed after 30 days using SEM and atomic ratio diagrams of Al/Ca versus Si/Ca and S/Ca versus Al/Ca were plotted. The hydration products of Portland cement replaced with 30% zirconium oxide mixed at water/cement ratio of 0.3 were calcium silicate hydrate, calcium hydroxide and minimal amounts of ettringite and monosulphate. The calcium hydroxide leached in HBSS solution resulted in an increase in the pH value. The zirconium oxide acted as inert filler and exhibited no reaction with the hydration by-products of Portland

  13. Contamination of tooth-colored mineral trioxide aggregate used as a root-end filling material: a bacterial leakage study.

    Science.gov (United States)

    Montellano, Angela M; Schwartz, Scott A; Beeson, Thomas J

    2006-05-01

    This experiment investigated the ability of tooth-colored mineral trioxide aggregate (MTA) to maintain an apical seal in the presence of bacteria when contaminated with blood, saline or saliva. Ninety extracted human teeth with single canals were randomly placed into six groups of 15. Canals were prepared to size 50. The apical 3 mm of each root was removed and 3 mm root-end preparations were made with a #329 bur. Root-end preparations in groups 1 through 3 were filled with MTA after contamination with blood, saline, or saliva, respectively. In group 4, uncontaminated root-end preparations were filled with MTA. Groups 5 and 6 served as negative and positive controls. A tube/tooth assembly was utilized to suspend each root end in Trypticase Soy Broth (TSB). The access chambers were filled with Staphylococcus epidermidis. Positive growth over thirty days was demonstrated by turbidity of the TSB. Vitek analysis was used to confirm the presence of S. epidermidis in the positive samples. Data evaluation consisted of a chi(2) analysis (p < 0.05). Although all experimental groups demonstrated leakage, tooth-colored MTA contaminated with saliva (group 3) leaked significantly more than the uncontaminated tooth-colored MTA (group 4) (p = 0.028).

  14. Cytotoxicity of newly developed pozzolan cement and other root-end filling materials on human periodontal ligament cell

    Directory of Open Access Journals (Sweden)

    Minju Song

    2014-02-01

    Full Text Available Objectives The purpose of this study was to evaluate in vitro cytotoxicity of the pozzolan cement and other root-end filling materials using human periodontal ligament cell. Materials and Methods Endocem (Maruchi, white ProRoot MTA (Dentsply, white Angelus MTA (Angelus, and Super EBA (Bosworth Co. were tested after set completely in an incubator at 37℃ for 7 days, Endocem was tested in two ways: 1 immediately after mixing (fresh specimens and 2 after setting completely like other experimental materials. The methods for assessment included light microscopic examination, cell counting and WST-1 assay on human periodontal ligament cell. Results In the results of microscopic examination and cell counting, Super EBA showed significantly lower viable cell than any other groups (p < 0.05. As the results of WST-1 assay, compared with untreated control group, there was no significant cell viability of the Endocem group. However, the fresh mixed Endocem group had significantly less cell viability. The cells exposed to ProRoot MTA and Angelus MTA showed the highest viability, whereas the cells exposed to Super EBA displayed the lowest viability (p < 0.05. Conclusions The cytotoxicity of the pozzolan cement (Endocem was comparable with ProRoot MTA and Angelus MTA. Considering the difficult manipulation and long setting time of ProRoot MTA and Angelus MTA, Endocem can be used as the alternative of retrofilling material.

  15. Evaluation of the physical properties of an endodontic Portland cement incorporating alternative radiopacifiers used as root-end filling material.

    Science.gov (United States)

    Camilleri, J

    2010-03-01

    To investigate the physical and chemical properties of Portland cement (PC) loaded with alternative radiopacifying materials for use as root-end filling materials in a mineral trioxide aggregate (MTA)-like system. Portland cement loaded with barium sulphate, gold and silver/tin alloy was mixed with water, and the physical and chemical properties of the hydrated cements were evaluated. MTA and intermediate restorative material (IRM) were used as controls. The radiopacity was compared to the equivalent thickness of aluminium, and the setting time of the cements was assessed using an indentation technique. The compressive strength and the stress-strain relationship were determined at 28 days. The stress-strain relationship was determined by monitoring the strain generated when the cement was subjected to compressive load. In addition, the pH was determined in water and simulated body fluid for a period of 28 days. The radiopacity of the cements using alternative radiopacifiers was comparable to MTA (P > 0.05). IRM demonstrated a higher radiopacity than all the materials tested (P cements with the exception of IRM exhibited an alkaline pH and had an extended setting time when compared to IRM. MTA had a longer setting time than the PC (P cement (P = 0.159). The addition of a radiopacifier retarded the setting time (P cements had comparable strength to PC (P > 0.05). IRM was the weakest cement tested (P cement loaded with gold radiopacifier had comparable strength to MTA (P = 1). The stress-strain relationship was linear for all the cements with IRM generating more strain on loading. Within the parameters set in this study, bismuth oxide in MTA can be replaced by gold or silver/tin alloy. The physical, mechanical and chemical properties of the cement replaced with alternative radiopacifiers were similar and comparable to ProRoot MTA.

  16. Evaluation of bacterial leakage of four root- end filling materials: Gray Pro Root MTA, White Pro Root MTA, Root MTA and Portland Cement (type I

    Directory of Open Access Journals (Sweden)

    Zarabian M.

    2005-07-01

    Full Text Available Background and Aim: Today several materials have been used for root- end filling in endodontic surgery. Optimal properties of Pro Root MTA in in-vitro and in-vivo studies has been proven. On the other hand, based on some studies, Root MTA (Iranian Pro Root MTA and Portland cement are similar to Pro Root MTA in physical and biologic properties. The aim of this study was to evaluate bacterial leakage (amount and mean leakage time of four root- end filling materials. Materials and Methods: In this experimental in-vitro study, seventy six extracted single- rooted human teeth were randomly divided into six groups for root-end filling with gray Pro Root MTA, white Pro Root MTA, Root MTA (Iranian Pro Root MTA, Portland Cement (type I and positive and negative control groups. Root canals were instrumented using the step- back technique. Root- end filling materials were placed in 3mm ultra sonic retro preparations. Samples and microleakage model system were sterilized in autoclave. The apical 3-4 mm of the roots were immersed in phenol red with 3% lactose broth culture medium. The coronal access of each specimen was inoculated every 24h with a suspension of Streptococcus sanguis (ATCC 10556. Culture media were observed every 24h for colour change indicating bacterial contamination for 60 days. Statistical analysis was performed using log- rank test with P<0.05 as the limit of significance. Results: At the end of study 50%, 56.25%, 56.25% and 50% of specimens filled with Gray Pro Root MTA, White Pro Root MTA. Root MTA and Portland Cement (type I had evidence of leakage respectively. The mean leakage time was 37.19±6.29, 36.44±5.81, 37.69±5.97 and 34.81±6.67 days respectively. Statistical analysis of data showed no significant difference among the leakage (amount and mean leakage time of the four tested root- end filling materials (P=0.9958. Conclusion: Based on the results of this study, there were no significant differences in leakage among the four

  17. The outcome of apical microsurgery using MTA as the root-end filling material: 2- to 6-year follow-up study.

    Science.gov (United States)

    Çalışkan, M K; Tekin, U; Kaval, M E; Solmaz, M C

    2016-03-01

    To evaluate the influence of various predictors on the healing outcome 2-6 years after apical microsurgery (AMS) using MTA as the root-end filling material. A total of 90 anterior teeth with asymptomatic persistent periradicular periodontitis of strictly endodontic origin that failed after either nonsurgical or surgical treatment were included. Surgery was completed under local anaesthesia using a standardized clinical protocol. Clinical and radiographic measures as well as the follow-up period were used to determine the healing outcome. For statistical analysis of the predictors, the outcome was dichotomized into healed cases and nonhealed cases. Odds ratios were calculated, and Pearson chi-square or Fisher's exact tests were used to analyse the data. Clinical and radiographic assessment of AMS revealed that 80% were healed, 14.4% were nonhealed, whilst 5.6% were judged to be uncertain. None of the various predictors investigated had a significant influence on the outcome of AMS. The results of this clinical study demonstrated that 80% of cases that received apical microsurgery healed when using MTA as the root-end filling material. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  18. Apical adaptation, sealing ability and push-out bond strength of five root-end filling materials

    Directory of Open Access Journals (Sweden)

    Pablo Andrés AMOROSO-SILVA

    2014-08-01

    Full Text Available This study compared the fluid filtration, adaptation to the root canal walls, and the push-out bond strength of two resin-based sealers and three calcium silicate-based retrograde filling materials. Fifty maxillary canines were shaped using manual instruments and the apical portion was sectioned. Retrograde cavities of 3-mm depth were prepared. The specimens were divided into five groups (n = 10: Sealer 26 (S26; MBPc (experimental; MTA; Portland cement with 20% zirconium oxide (PC/ZO, and Portland cement with 20% calcium tungstate (PC/CT. The fluid filtration was measured at 7 and 15 days. To evaluate the interfacial adaptation, sections of the teeth, 1 and 2 mm from the apex, were prepared and the percentage of gaps was calculated. The push-out bond strength at 2 mm from the apex was evaluated. Statistical analysis was performed using the ANOVA/Tukey’s test (p < 0.05. At 7 and 15 days (p = 0.0048, p = 0.006, the PC/CT group showed higher fluid filtration values when compared to other groups. At 1 mm from the apex, no statistical differences in the adaptation were found among the cements (p = 0.44. At 2 mm from the apex, the PC/ZO group presented statistically lower percentage of gaps than S26, MBPc, and MTA (p = 0.0007. The MBPc group showed higher push-out bond strength than other cements evaluated (p = 0.0008. The fluid filtration and interfacial adaptation of the calcium silicate-based cements were similar to those of the resin-based cements. The resinous cement MBPc showed superior push-out bond strength.

  19. Cytotoxicity and Initial Biocompatibility of Endodontic Biomaterials (MTA and Biodentine™) Used as Root-End Filling Materials.

    Science.gov (United States)

    Escobar-García, Diana María; Aguirre-López, Eva; Méndez-González, Verónica; Pozos-Guillén, Amaury

    2016-01-01

    Objective. The aim of this study was to evaluate the cytotoxicity and cellular adhesion of Mineral Trioxide Aggregate (MTA) and Biodentine (BD) on periodontal ligament fibroblasts (PDL). Methods. PDL cells were obtained from nonerupted third molars and cultured; MTS cellular profusion test was carried out in two groups: MTA and BD, with respective controls at different time periods. Also, the LIVE/DEAD assay was performed at 24 h. For evaluation of cellular adhesion, immunocytochemistry was conducted to discern the expression of Integrin β1 and Vinculin at 12 h and 24 h. Statistical analysis was performed by the Kruskal-Wallis and Mann-Whitney U tests. Results. MTA and BD exhibited living cells up to 7 days. More expressions of Integrin β1 and Vinculin were demonstrated in the control group, followed by BD and MTA, which also showed cellular loss and morphological changes. There was a significant difference in the experimental groups cultured for 5 and 7 days compared with the control, but there was no significant statistical difference between both cements. Conclusions. Neither material was cytotoxic during the time evaluated. There was an increase of cell adhesion through the expression of focal contacts observed in the case of BD, followed by MTA, but not significantly.

  20. Sealing ability of white and gray mineral trioxide aggregate mixed with distilled water and 0.12% chlorhexidine gluconate as a root end filling material: An ex vivo evaluation

    Directory of Open Access Journals (Sweden)

    Sreegowri

    2013-01-01

    Full Text Available Aim: The aim of this study was to evaluate the sealing ability of white and gray mineral trioxide aggregate (MTA mixed with distilled water and 0.12% chlorhexidine (CHX gluconate when used as a root-end filling material using the dye-penetration technique. Materials and Methods: A total of 48 single-rooted human teeth were cleaned, shaped, and obturated with gutta-percha and AH Plus sealer. The apical 3 mm of each root was resected, and 3-mm deep root-end cavity preparations were made. The teeth were randomly divided into 4 experimental groups, each containing 8 teeth, and 2 negative and positive control groups, each containing 8 teeth. Root-end cavities in the experimental groups were filled with the experimental materials. After application of nail polish, the teeth were exposed to India ink for 72 h and longitudinally sectioned, and the extent of dye penetration was measured with a stereomicroscope. Results : No statistically significant differences were observed in the sealing ability of gray and white MTA mixed with distilled water and 0.12% CHX. Conclusion : CHX appears to be a good alternative to replace distilled water, as a solution to be mixed with MTA.

  1. Periapical tissue response after use of intermediate restorative material, gutta-percha, reinforced zinc oxide cement, and mineral trioxide aggregate as retrograde root-end filling materials: a histologic study in dogs.

    Science.gov (United States)

    Wälivaara, Dan-Åke; Abrahamsson, Peter; Isaksson, Sten; Salata, Luiz Antonio; Sennerby, Lars; Dahlin, Christer

    2012-09-01

    To investigate the periapical tissue response of 4 different retrograde root-filling materials, ie, intermediate restorative material, thermoplasticized gutta-percha, reinforced zinc oxide cement (Super-EBA), and mineral trioxide aggregate (MTA), in conjunction with an ultrasonic root-end preparation technique in an animal model. Vital roots of the third and fourth right mandibular premolars in 6 healthy mongrel dogs were apicectomized and sealed with 1 of the materials using a standardized surgical procedure. After 120 days, the animals were sacrificed and the specimens were analyzed radiologically, histologically, and scanning electron microscopically. The Fisher exact test was performed on the 2 outcome values. Twenty-three sections were analyzed histologically. Evaluation showed better re-establishment of the periapical tissues and generally lower inflammatory infiltration in the sections from teeth treated with the intermediate restorative material and the MTA. New root cement on the resected dentin surfaces was seen on all sections regardless of the used material. New hard tissue formation, directly on the surface of the material, was seen only in the MTA sections. There was no statistical difference in outcome among the tested materials. The results from this dog model favor the intermediate restorative material and MTA as retrograde fillings when evaluating the bone defect regeneration. MTA has the most favorable periapical tissue response when comparing the biocompatibility of the materials tested. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Effect of two storage solutions on surface topography of two root-end fillings.

    Science.gov (United States)

    Asgary, Saeed; Eghbal, Mohammad Jafar; Parirokh, Masoud; Ghoddusi, Jamileh

    2009-12-01

    The effect of different storage solutions on surface topography of mineral trioxide aggregate (MTA) and new experimental cement (NEC) as root-end fillings was investigated. Twenty-four single-rooted teeth were cleaned, shaped and obturated in a same manner. After root-end resection, 3-mm deep root-end cavities were ultrasonically prepared. Samples were randomly divided into four test groups (A1-A2-B1-B2, n = 6). Root-end cavities in groups A and B were filled with MTA and NEC, respectively, and were then stored in 100% humidity for 24 h. The samples of groups 1 and 2 were, respectively, immersed in normal saline (NS) and phosphate buffer saline solutions for 1 week. The samples were imaged under stereomicroscope before and after immersion and were then investigated and analysed by scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDXA). Results showed significant difference among studied groups. Surface topography of all samples was altered by crystal formation and precipitation on root-end fillings except for group A1 (MTA-NS). SEM and EDXA results showed that the composition and structure of precipitated crystals were comparable with that of standard hydroxyapatite. It was concluded that biocompatibility, sealing ability, and cementogenic activity of MTA and probably NEC may be attributed to this fundamental bioactive reaction.

  3. Prognostic factors in apical surgery with root-end filling: a meta-analysis

    DEFF Research Database (Denmark)

    von Arx, Thomas; Peñarrocha, Miguel; Jensen, Simon Storgård

    2010-01-01

    Apical surgery has seen continuous development with regard to equipment and surgical technique. However, there is still a shortage of evidence-based information regarding healing determinants. The objective of this meta-analysis was to review clinical articles on apical surgery with root-end fill...

  4. Clinical results with two different methods of root-end preparation and filling in apical surgery: mineral trioxide aggregate and adhesive resin composite

    DEFF Research Database (Denmark)

    von Arx, Thomas; Hanni, Stefan; Jensen, Simon Storgaard

    2010-01-01

    The aim of apical surgery is to hermetically seal the root canal system after root-end resection, thereby enabling periradicular healing. The objective of this nonrandomized prospective clinical study was to report results of 2 different root-end preparation and filling methods, ie, mineral triox...

  5. Molar apicectomy with amalgam root-end filling: results of a prospective study in two district general hospitals.

    Science.gov (United States)

    Wesson, C M; Gale, T M

    2003-12-20

    To determine the five-year success rates, site or sites of failure, prognostic indicators and lower lip morbidity associated with molar apicectomy using amalgam root-end filling. Multicentre, prospective study. The departments of oral and maxillo-facial surgery in two district general hospitals. One thousand and seven molar apicectomy procedures, combined with amalgam root-end filling were expedited during the period 1974-1995. A five-year review of each operated tooth was carried out or attempted between 1979-2000. Of the 790 (78%) operated molars successfully reviewed at 5 years or later 451 (57%) exhibited 'complete healing' and 39 (5%) 'uncertain healing'. Three hundred (38%) were classified as 'unsatisfactory healing' (failures), and these included 12 which were assumed to be of periodontal origin. Whilst longitudinal root fracture, perforation and/or infection in the furcation, periodontal disease or a non-restorable crown accounted for treatment failure and often the need to remove teeth subsequently, the study probably pointed to the apical ends of the roots rather than the furcation as being the major sites at which 'unsatisfactory healing' occurred. Mandibular first molars attracted the highest 'complete healing' rate (60%) and mandibular second molars the lowest (46%). 'Good' root canal treatment (RCT) at the outset improved the prognosis of a root-end filling (REF) whilst the absence of RCT compromised it. Cystic change pointed to a better prognosis than apical granulomatous change as did a deep compared with a shallow 'bone cuff'. Disease at the furcation suggested a worse prognosis. Teeth which showed 'complete healing' at 1 year had a 75% probability of maintaining this outcome at 5 years. Sensory disturbance of variable duration occurred in the lower lip following 20-21% of mandibular molar procedures. In the majority of cases (79-80%) this had remitted within 3 months. A permanent deficit occurred in 8 patients (1%) where the apicectomy could

  6. Push-out bond strength of different tricalcium silicate-based filling materials to root dentin

    Directory of Open Access Journals (Sweden)

    Jorge Henrique Stefaneli Marques

    2018-03-01

    Full Text Available Abstract: The aim of this study was to evaluate the bond strength of different triccalcium silicate cements to retrograde cavity using a push out test. Thirty maxillary central incisors were shaped using #80 hand files and sectioned transversally. Root slices were obtained from the apical 4 mm after eliminating the apical extremity. The specimens were embedded in acrylic resin and positioned at 45° to the horizontal plane for preparation of root-end cavities with a diamond ultrasonic retrotip. The samples were divided into three groups according to the root-end filling material (n = 10: MTA Angelus, ProRoot MTA and Biodentine. A gutta-percha cone (#80 was tugged-back at the limit between the canal and the root-end cavity. The root-end cavity was filled and the gutta-percha cone was removed after complete setting of the materials. The specimens were placed in an Instron machine with the root-end filling turned downwards. The push-out shaft was inserted in the space previously occupied by the gutta-percha cone and push out testing was performed at a crosshead speed of 1.0 mm/min. There was no statistically significant difference in resistance to push out by the materials tested (p > 0.01. MTA Angelus and ProRoot MTA showed predominantly mixed failure while Biodentine exhibited mixed and cohesive failures. The tricalcium silicate-based root-end filling materials showed similar bond strength retrograde cavity.

  7. Push-out bond strength of different tricalcium silicate-based filling materials to root dentin.

    Science.gov (United States)

    Stefaneli Marques, Jorge Henrique; Silva-Sousa, Yara Teresinha Corrêa; Rached-Júnior, Fuad Jacob Abi; Macedo, Luciana Martins Domingues de; Mazzi-Chaves, Jardel Francisco; Camilleri, Josette; Sousa-Neto, Manoel Damião

    2018-03-08

    The aim of this study was to evaluate the bond strength of different triccalcium silicate cements to retrograde cavity using a push out test. Thirty maxillary central incisors were shaped using #80 hand files and sectioned transversally. Root slices were obtained from the apical 4 mm after eliminating the apical extremity. The specimens were embedded in acrylic resin and positioned at 45° to the horizontal plane for preparation of root-end cavities with a diamond ultrasonic retrotip. The samples were divided into three groups according to the root-end filling material (n = 10): MTA Angelus, ProRoot MTA and Biodentine. A gutta-percha cone (#80) was tugged-back at the limit between the canal and the root-end cavity. The root-end cavity was filled and the gutta-percha cone was removed after complete setting of the materials. The specimens were placed in an Instron machine with the root-end filling turned downwards. The push-out shaft was inserted in the space previously occupied by the gutta-percha cone and push out testing was performed at a crosshead speed of 1.0 mm/min. There was no statistically significant difference in resistance to push out by the materials tested (p > 0.01). MTA Angelus and ProRoot MTA showed predominantly mixed failure while Biodentine exhibited mixed and cohesive failures. The tricalcium silicate-based root-end filling materials showed similar bond strength retrograde cavity.

  8. Radiopacity of root filling materials

    International Nuclear Information System (INIS)

    Beyer-Olsen, E.M.

    1983-01-01

    A method for measuring the radiopacity of root filling materials is described. Direct measurements were made of the optic density values of the materials in comparison with a standard curve relating optic density to the thickness of an aluminium step wedge exposed simultaneously. By proper selection of film and conditions for exposure and development, it was possible to obtain a near-linear standard curve which added to the safety and reproducibility of the method. The technique of radiographic assessment was modified from clinical procedures in evaluating the obturation in radiographs, and it was aimed at detecting slits or voids between the dental wall and the filling material. This radiographic assessment of potensial leakage was compared with actual in vitro lekage of dye (basic fuchsin) into the roots of filled teeth. The result of the investigation show that root filling materials display a very wide range of radiopacity, from less than 3 mm to more than 12 mm of aluminium. It also seem that tooth roots that appear to be well obturated by radiographic evaluation, stand a good chance of beeing resistant to leakage in vitro, and that the type of filling material rather than its radiographic appearance, determines the susceptibility of the filled tooth to leakage in vitro. As an appendix the report contains a survey of radiopaque additives in root filling materials

  9. Removal of root filling materials.

    LENUS (Irish Health Repository)

    Duncan, H.F. Chong, B.S.

    2011-05-01

    Safe, successful and effective removal of root filling materials is an integral component of non-surgical root canal re-treatment. Access to the root canal system must be achieved in order to negotiate to the canal terminus so that deficiencies in the original treatment can be rectified. Since a range of materials have been advocated for filling root canals, different techniques are required for their removal. The management of commonly encountered root filling materials during non-surgical re-treatment, including the clinical procedures necessary for removal and the associated risks, are reviewed. As gutta-percha is the most widely used and accepted root filling material, there is a greater emphasis on its removal in this review.

  10. Microhardness of bulk-fill composite materials

    OpenAIRE

    Kelić, Katarina; Matić, Sanja; Marović, Danijela; Klarić, Eva; Tarle, Zrinka

    2016-01-01

    The aim of the study was to determine microhardness of high- and low-viscosity bulk-fill composite resins and compare it with conventional composite materials. Four materials of high-viscosity were tested, including three bulk-fills: QuiXfi l (QF), x-tra fil (XTF) and Tetric EvoCeram Bulk Fill (TEBCF), while nanohybrid composite GrandioSO (GSO) served as control. The other four were low-viscosity composites, three bulk-fill materials: Smart Dentin Replacement (SDR), Venus Bulk Fill (VBF) and ...

  11. Comparative evaluation of microleakage of various retrograde filling materials: An in vitro study.

    Science.gov (United States)

    Galhotra, Virat; Sofat, Anjali; Pandit, Inder K; Gambhir, Ramandeep Singh; Srivastava, Nikhil; Gugnani, Neeraj

    2013-07-01

    The present study is envisaged to evaluate and compare the microleakage of mineral trioxide aggregate (MTA) with commonly used retrograde filling materials, like light-cured composite with dentin-bonding agents, light-cured glass ionomer cement (LC GIC) and resin-modified zinc oxide eugenol. Ninety freshly extracted non-carious single-rooted human anterior teeth were used in the study. They were randomly divided into four experimental groups and two control groups of 15 each. Following the biomechanical preparation, all teeth were obturated and then the apices of the obturated teeth were resected by removing 3 mm of each apex at 90° to the long axis of the tooth with a straight fissure bur in a high-speed air-rotor handpiece with water coolant. A 3-mm-deep root end cavity was prepared and the root end fillings were placed as per the manufacturer's instructions and according to the groups divided. The samples were then immersed in 1% methylene blue at room temperature for 72 h, 96 h and 1 week and the dye penetration was measured. All the four materials used in the study showed some microleakage throughout the experimental period. The sealing ability in terms of microleakage can be summarized as: MTA > Composite resin with dentin bonding agent > LC GIC > Resin modified zinc oxide eugenol.

  12. Topological materials discovery using electron filling constraints

    Science.gov (United States)

    Chen, Ru; Po, Hoi Chun; Neaton, Jeffrey B.; Vishwanath, Ashvin

    2018-01-01

    Nodal semimetals are classes of topological materials that have nodal-point or nodal-line Fermi surfaces, which give them novel transport and topological properties. Despite being highly sought after, there are currently very few experimental realizations, and identifying new materials candidates has mainly relied on exhaustive database searches. Here we show how recent studies on the interplay between electron filling and nonsymmorphic space-group symmetries can guide the search for filling-enforced nodal semimetals. We recast the previously derived constraints on the allowed band-insulator fillings in any space group into a new form, which enables effective screening of materials candidates based solely on their space group, electron count in the formula unit, and multiplicity of the formula unit. This criterion greatly reduces the computation load for discovering topological materials in a database of previously synthesized compounds. As a demonstration, we focus on a few selected nonsymmorphic space groups which are predicted to host filling-enforced Dirac semimetals. Of the more than 30,000 entires listed, our filling criterion alone eliminates 96% of the entries before they are passed on for further analysis. We discover a handful of candidates from this guided search; among them, the monoclinic crystal Ca2Pt2Ga is particularly promising.

  13. Analysis of marginal seal of ProRoot MTA, MTA Angelus biodentine, and glass ionomer cement as root-end filling materials: An in vitro study

    Directory of Open Access Journals (Sweden)

    Sakshi Malhotra

    2015-01-01

    Conclusion: Microleakage was present in all the samples. Least amount of apical dye microleakage was seen in biodentine with mean value of 0.16 mm followed by ProRoot MTA 0.68 mm, MTA Angelus 0.74 mm, and GIC 1.53 mm. The best sealing ability was seen in biodentine, and this difference was statistically significant.

  14. Carbon Nanotubes Filled with Ferromagnetic Materials

    Directory of Open Access Journals (Sweden)

    Albrecht Leonhardt

    2010-08-01

    Full Text Available Carbon nanotubes (CNT filled with ferromagnetic metals like iron, cobalt or nickel are new and very interesting nanostructured materials with a number of unique properties. In this paper we give an overview about different chemical vapor deposition (CVD methods for their synthesis and discuss the influence of selected growth parameters. In addition we evaluate possible growth mechanisms involved in their formation. Moreover we show their identified structural and magnetic properties. On the basis of these properties we present different application possibilities. Some selected examples reveal the high potential of these materials in the field of medicine and nanotechnology.

  15. Carbon Nanotubes Filled with Ferromagnetic Materials

    Science.gov (United States)

    Weissker, Uhland; Hampel, Silke; Leonhardt, Albrecht; Büchner, Bernd

    2010-01-01

    Carbon nanotubes (CNT) filled with ferromagnetic metals like iron, cobalt or nickel are new and very interesting nanostructured materials with a number of unique properties. In this paper we give an overview about different chemical vapor deposition (CVD) methods for their synthesis and discuss the influence of selected growth parameters. In addition we evaluate possible growth mechanisms involved in their formation. Moreover we show their identified structural and magnetic properties. On the basis of these properties we present different application possibilities. Some selected examples reveal the high potential of these materials in the field of medicine and nanotechnology. PMID:28883334

  16. Colloid transport in model fracture filling materials

    Science.gov (United States)

    Wold, S.; Garcia-Garcia, S.; Jonsson, M.

    2010-12-01

    Colloid transport in model fracture filling materials Susanna Wold*, Sandra García-García and Mats Jonsson KTH Chemical Science and Engineering Royal Institute of Technology, SE-100 44 Stockholm, Sweden *Corresponding author: E-mail: wold@kth.se Phone: +46 8 790 6295 In colloid transport in water-bearing fractures, the retardation depends on interactions with the fracture surface by sorption or filtration. These mechanisms are difficult to separate. A rougher surface will give a larger area available for sorption, and also when a particle is physically hindered, it approaches the surface and enables further sorption. Sorption can be explained by electrostatics were the strongest sorption on minerals always is observed at pH below pHpzc (Filby et al., 2008). The adhesion of colloids to mineral surfaces is related to the surface roughness according to a recent study (Darbha et al., 2010). There is a large variation in the characteristics of water-bearing fractures in bedrock in terms of aperture distribution, flow velocity, surface roughness, mineral distributions, presence of fracture filling material, and biological and organic material, which is hard to implement in modeling. The aim of this work was to study the transport of negatively charged colloids in model fracture filling material in relation to flow, porosity, mineral type, colloid size, and surface charge distribution. In addition, the impact on transport of colloids of mixing model fracture filling materials with different retention and immobilization capacities, determined by batch sorption experiments, was investigated. The transport of Na-montmorillonite colloids and well-defined negatively charged latex microspheres of 50, 100, and 200 nm diameter were studied in either columns containing quartz or quartz mixed with biotite. The ionic strength in the solution was exclusively 0.001 and pH 6 or 8.5. The flow rates used were 0.002, 0.03, and 0.6 mL min-1. Sorption of the colloids on the model fracture

  17. 21 CFR 872.3310 - Coating material for resin fillings.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Coating material for resin fillings. 872.3310... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3310 Coating material for resin fillings. (a) Identification. A coating material for resin fillings is a device intended to be applied to the...

  18. Dentin penetrability evaluation of three different dyes in root-end cavities filled with mineral trioxide aggregate (MTA Avaliação da penetração dentinária de três diferentes corantes em retrocavidades obturadas com agregado trióxido mineral (MTA

    Directory of Open Access Journals (Sweden)

    Beatriz Farias Vogt

    2006-04-01

    Full Text Available The purpose of this study was to evaluate the penetration of three dyes in MTA root-end fillings. In 30 single-rooted teeth, cavities for retrofilling were prepared with an ultrasound appliance and filled with MTA. The specimens were randomly assigned to three groups (n = 10 and immersed in the following solutions: 2% methylene blue (MET, 50% silver nitrate (NIT and 0.2% rhodamine B (ROD. Two transversal slices (1 mm of the retrofilling region were obtained and evaluated using the Image Tool 3.0 software to obtain a quantitative evaluation (in mm² of the dye penetration around the retrofillings. Data were submitted to statistical analysis using Student’s t-test. The lowest degree of dye penetration was observed for the NIT group, in both slices (p A proposta deste trabalho foi avaliar a penetração de três corantes em retrocavidades obturadas com MTA. As retrocavidades foram confeccionadas com aparelho de ultra-som em 30 dentes unirradiculares e obturadas com MTA. Os espécimes foram divididos aleatoriamente em três grupos (n = 10 e imersos nas seguintes soluções corantes: azul de metileno a 2% (MET, nitrato de prata a 50% (NIT e rodamina B a 0,2% (ROD. Duas fatias transversais (1 mm da região retrobturada foram obtidas e avaliadas através do software Image Tool 3.0, objetivando quantificar a área (em mm² de penetração do corante ao redor das retrobturações. Os dados foram submetidos à análise estatística, utilizando o teste t de Student. A menor área de penetração foi observada no grupo NIT, nas duas fatias (p < 0.05. A penetração de corante foi significativamente maior no grupo ROD quando comparado ao grupo NIT, nas duas fatias (p < 0.05, e ao grupo MET, somente na fatia 1 (p < 0.05. Dentro das limitações desta pesquisa, concluiu-se que a escolha da solução corante pode influenciar a avaliação da penetração em estudos sobre retrobturações e que o grupo NIT teve a menor capacidade de penetração na dentina

  19. Sorption of Np (Ⅴ) on Beishan granite fracture filling materials

    International Nuclear Information System (INIS)

    Jiang Tao; Wang Bo; Bao Liangjin; Zhou Duo; Long Haoqi; Song Zhixin; Chen Xi

    2012-01-01

    The sorption behaviors of Np (Ⅴ) on the granite fracture filling materials were studied by batch experiments under anaerobic in Beishan groundwater. The impact of pH of groundwater, CO 3 2- , humic acid and different components of granite fracture filling materials on sorption of Np (Ⅴ) was investigated. The results show that the granite fracture filling materials have strong capacity of Np (Ⅴ) adsorption. The value of K d , for Np (Ⅴ) sorption on the granite fracture filling materials is 843 mL/g. With the increase of pH, the value of K d increases at first and then decreases. K d of Np sorption on granite fracture filling materials in the presence of CO 3 2- and humic acid decreases. The chlorite and feldspar are major contributors to the sorption of Np (Ⅴ) on Beishan granite fracture filling materials. (authors)

  20. Mechanical behaviour of dental composite filling materials using digital holography

    OpenAIRE

    Monteiro, J.M.; Lopes, H.; Vaz, M.A.P.; Campos, J.C. Reis

    2010-01-01

    One of the most common clinical problems in dentistry is tooth decay. Among the dental filling materials used to repair tooth structure that has been destroyed by decay are dental amalgam and composite materials based on acrylics. Dental amalgam has been used by dentists for the past 150 years as a dental restorative material due to its low cost, ease of application, strength, durability, and bacteriostatic effects. However its safety as a filling material has been questioned due to th...

  1. CHARACTERISTICS OF FLORIDA FILL MATERIALS AND SOILS 1990

    Science.gov (United States)

    The report gives results of laboratory work by the University of Florida in support of the Foundation Fill Data Base project of the Foundation Fill Materials Specifications Task Area of the Florida Radon Research Program (FRRP). Work included determination of radon concentrations...

  2. Stress analysis of advanced attack helicopter composite main rotor blade root end lug

    Science.gov (United States)

    Baker, D. J.

    1982-01-01

    Stress analysis of the Advanced Attack Helicopter (AAH) composite main rotor blade root end lug is described. The stress concentration factor determined from a finite element analysis is compared to an empirical value used in the lug design. The analysis and test data indicate that the stress concentration is primarily a function of configuration and independent of the range of material properties typical of Kevlar-49/epoxy and glass epoxy.

  3. Effect of Different Filling Materials in Anammox Bacteria Enrichment

    Directory of Open Access Journals (Sweden)

    Dilek ÖZGÜN

    2012-12-01

    Full Text Available Purpose: Anaerobic ammonium oxidation (Anammox is a process that ammonium as electron donor is oxidized to nitrogen gas using nitrite as electron acceptor. Compared to conventional nitrification-denitrification processes, this process is used less oxygen and no organic material (methanol, glucose. However, the slow growth rate of Anammox bacteria (11-30 days is disadvantages. Therefore, batch reactors have been carried out in these bacteria enrichment. In this study continuously operated upflow anaerobic sludge reactor (UASB using different filling materials disposing of sensitive and slow-growing Anammox bacteria out of the system is purposed. Design and Methods: System is operated up-flow column reactor at 2 days hydraulic retention time (HRT in 45 days. In this study, ceramic stones and Linpor filling material are used. Using synthetic wastewater containing ammonium and nitrite, Ar/CO2 anaerobic conditions (95/5% supplied with gas. System is operated at a temperature 253 C in UASB. Temperature, pH, ammonia-nitrogen and nitrite nitrogen are measured. Results: Both filling material reactors are operated in 45 days. Ceramic stones filling reactor is observed quickly reaches 90% were used reactor ammonium removal. The ammonium nitrogen removal was slower in Linpor filling materials reactor. Nitrite removal is reached up to 90% in both the reactor. When compared to the stoichiometric equation in Linpor was composed of large amounts of nitrate. At the end of 25 days the results were similar to ceramic stone filling reactor with Linpor filling material reactors. Conclusions and Original Value: Anammox process as from nitrogen removal processes was discovered in 1995. Anammox bacteria that make up this process due to very low growth rates of microbial bacteria in the system must be kept in the system. Most of the studies in the literature, these bacteria enrichment stage is started instead of a continuous batch reactor system. In this study

  4. Experimental study of strontium sorption on fissure filling material

    Energy Technology Data Exchange (ETDEWEB)

    Eriksen, T E; Cui, Daqing [Royal Institute of Technology, Stockholm (Sweden). Dept. of Chemistry

    1994-12-01

    We have carried out a comparative study of sorption and desorption of strontium in groundwater on separated magnetic and size fractions of fissure filling material taken from natural fissures in granitic rock. Complete reversibility of the sorption process was demonstrated by identical Freundlich isotherms, isotopic exchangeability and pH dependence of the distribution coefficients Rd. The sorption was found to be strongly pH dependent in the range 3-11. The pH effect can be accommodated in the sorption model by considering the surface areas and surface charges of the minerals in the fissure filling material. 20 refs, 9 figs, 3 tabs.

  5. Experimental study of strontium sorption on fissure filling material

    International Nuclear Information System (INIS)

    Eriksen, T.E.; Cui, Daqing

    1994-12-01

    We have carried out a comparative study of sorption and desorption of strontium in groundwater on separated magnetic and size fractions of fissure filling material taken from natural fissures in granitic rock. Complete reversibility of the sorption process was demonstrated by identical Freundlich isotherms, isotopic exchangeability and pH dependence of the distribution coefficients Rd. The sorption was found to be strongly pH dependent in the range 3-11. The pH effect can be accommodated in the sorption model by considering the surface areas and surface charges of the minerals in the fissure filling material. 20 refs, 9 figs, 3 tabs

  6. Experimental Study of Goaf Filling Materials Based on Red Mud

    Science.gov (United States)

    Mu, Mangen; Gao, Xiaozhen; Guo, Taoming; Hu, Xinping

    2018-01-01

    Red mud as soild waste is difficult to treatment. Goaf filling materials can make a large use of red mud. By the experimental study,we find that the red mud, fly ash, ground slag and desulfida-tion gypsum can be used to make goaf filling materials based on the principle of alkali excitation and metalion stability.Through the control variable method, we find that the optimal proportion of goaf filling materials based on red mud is red mud 55%, fly ash 30%, cement 7.5%, fly ash 2.5%, desulfurization gypsum 5%, admixture 1%, and water solid ratio=1:1.2.The 28days final material strength was 2.0 MPa,which achives the technical specification requirements.Through the test of SEM, XRD and IR, it is indicated that the strength formation of goaf filling material based on red mud is from the unformed linking hydration products of amorphous alkali excitation system. With curing time from 3 to 7 days, the unformed linking hydration products grown a lot of vitreous hydration products. When hydration reaction basicly finished after 28 days, the hydration products have developed into a large volume of massive vitreous with an extremely dense structure. The Ca2SiO3 mineral phase is significantly reduced, which is participate in hydration reactions. The decrease of Ca2SiO3 indicates that the Si-O bond in the system have been ruptured and reorganized.

  7. Multifunctional composite material based on carbon-filled polyurethane

    International Nuclear Information System (INIS)

    Malinovskaya, T; Melentyev, S; Pavlov, S

    2015-01-01

    The research paper deals with the performance of composite resistive material heating coatings based on the polyurethane binder, filled with colloidal-graphite preparation C- 1, which can be used in structures of electric heaters. Frequency dependences of transmission and reflection coefficients, dielectric permeability of composite materials with the various content of carbon fillers (technical carbon, graphite) in polyurethane varnish in ranges of frequencies 26-40 GHz and 110-260 GHz are experimentally investigated. (paper)

  8. Contrast material filling of the peroneal tendon sheath

    International Nuclear Information System (INIS)

    Zadravecz, Gy.; Grexa, E.

    1981-01-01

    In case of complaints after fracture of the calcaneus the common sheath of the peroneus tendons was filled up with contrast material. The tendon sheath was punctured Oehind the external ankle. The three-directional radiograms clearly showed the dislocation and compression of the tendons, caused by the exostosis of the calcaneus. The concomitant tendovaginitis caused the complaints. This alteration was observed in 11% of all the calcaneus fractures. (L.E.)

  9. Development of the foremost light-curable calcium-silicate MTA cement as root-end in oral surgery. Chemical-physical properties, bioactivity and biological behavior.

    Science.gov (United States)

    Gandolfi, Maria Giovanna; Taddei, Paola; Siboni, Francesco; Modena, Enrico; Ciapetti, Gabriela; Prati, Carlo

    2011-07-01

    An innovative light-curable calcium-silicate cement containing a HEMA-TEGDMA-based resin (lc-MTA) was designed to obtain a bioactive fast setting root-end filling and root repair material. lc-MTA was tested for setting time, solubility, water absorption, calcium release, alkalinizing activity (pH of soaking water), bioactivity (apatite-forming ability) and cell growth-proliferation. The apatite-forming ability was investigated by micro-Raman, ATR-FTIR and ESEM/EDX after immersion at 37°C for 1-28 days in DPBS or DMEM+FBS. The marginal adaptation of cement in root-end cavities of extracted teeth was assessed by ESEM/EDX, and the viability of Saos-2 cell on cements was evaluated. lc-MTA demonstrated a rapid setting time (2min), low solubility, high calcium release (150-200ppm) and alkalinizing power (pH 10-12). lc-MTA proved the formation of bone-like apatite spherulites just after 1 day. Apatite precipitates completely filled the interface porosities and created a perfect marginal adaptation. lc-MTA allowed Saos-2 cell viability and growth and no compromising toxicity was exerted. HEMA-TEGDMA creates a polymeric network able to stabilize the outer surface of the cement and a hydrophilic matrix permeable enough to allow water absorption. SiO(-)/Si-OH groups from the mineral particles induce heterogeneous nucleation of apatite by sorption of calcium and phosphate ions. Oxygen-containing groups from poly-HEMA-TEGDMA provide additional apatite nucleating sites through the formation of calcium chelates. The strong novelty was that the combination of a hydraulic calcium-silicate powder and a poly-HEMA-TEGDMA hydrophilic resin creates the conditions (calcium release and functional groups able to chelate Ca ions) for a bioactive fast setting light-curable material for clinical applications in dental and maxillofacial surgery. The first and unique/exclusive light-curable calcium-silicate MTA cement for endodontics and root-end application was created, with a potential

  10. Innovations in endodontic filling materials: guttapercha vs Resilon.

    Science.gov (United States)

    de Souza Filho, Francisco José; Gallina, Giuseppe; Gallottini, Livio; Russo, Riccardo; Cumbo, Enzo Maria

    2012-01-01

    One of the goals of endodontic treatment is to achieve a complete, tridimensional, hermetic sealing of the root canal system to prevent the entry of microorganisms or their products through both the coronal and apical pathways. Gutta-percha is the most widely used material for root canal filling and despite its numerous properties, such as biocompatibility and thermoplasticity, it has however an important limit: the lack of adhesion to the canal walls. Attempts to address this problem have been made over the years by using endodontic cements capable of bonding to canal dentine but their tendency to resorption in time can compromise the quality of treatment. The first step towards a real adhesive endodontic filling(4) is rather recent; in fact, it goes back to 2003 when, on the occasion of the American Dental Association (ADA) Annual Session, Resilon Research LLC introduced a new canal filling adhesive system based on a thermoplastic synthetic resin material called Resilon™. The real innovation of this system is its capacity of creating a core made of Resilon™ bonded to the cement which adheres to dentine walls previously conditioned with a self-etching primer(4) so no changes in the techniques of canal preparation are required. The aim of this study was to evaluate the capacity of two filling materials (gutta-percha and Resilon) to adapt to the canal anatomy, especially on the apical third, using the continuous wave of condensation technique. Our data suggest that in the third apical the gutta-percha best shows rheological properties that are as important as the bond capability.

  11. Comparative evaluation of low cost materials as constructed wetland filling media

    Science.gov (United States)

    Pinho, Henrique J. O.; Vaz, Mafalda M.; Mateus, Dina M. R.

    2017-11-01

    Three waste materials from civil construction activities were assessed as low cost alternative filling materials used in Constructed Wetlands (CW). CW are green processes for wastewater treatment, whose design includes an appropriate selection of vegetation and filling material. The sustainability of such processes may be incremented using recovered wastes as filling materials. The abilities of the materials to support plant growth and to contribute to pollutants removal from wastewater were assessed and compared to expanded clay, a filling usually used in CW design. Statistical analysis, using one-way ANOVA and Welch's ANOVA, demonstrate that limestone fragments are a better choice of filling material than brick fragments and basalt gravel.

  12. Color of bulk-fill composite resin restorative materials.

    Science.gov (United States)

    Barutcigil, Çağatay; Barutcigil, Kubilay; Özarslan, Mehmet Mustafa; Dündar, Ayşe; Yilmaz, Burak

    2018-03-01

    To evaluate the color stability of novel bulk-fill composite resins. Color measurements of a nanohybrid composite resin (Z550) and 3 bulk-fill composite resins (BLK, AFX, XTF; n = 45) were performed before polymerization. After polymerization, color measurements were repeated and specimens were immersed in distilled water or red wine, or coffee. Color change [CIEDE2000 (ΔE 00 )] was calculated after 24 h, 1 and 3 weeks. Data were analyzed with Kruskal-Wallis, Mann-Whitney U and Wilcoxon tests (α = 0.05). Color changes observed after polymerization were significant for all groups. Color changes observed in distilled water for Z550 and AFX were significant. Color changes after stored in red wine and coffee were significant for all groups. Bulk-fill composite resin color change increased over time for all groups in red wine and coffee (P composite resin and bulk-fill composite resins. AFX had the highest color change in distilled water. The color of tested bulk-fill composite resins significantly changed after immersion in beverages and over time. Color change observed with the nanohybrid composite resin after 1 week was stable. Clinicians should keep in mind that tested composite resins may change color when exposed to water and significantly change color immediately after they are polymerized. In addition, the color change continues over time should the patient is a coffee and/or red wine consumer. © 2017 Wiley Periodicals, Inc.

  13. The application of waste fly ash and construction-waste in cement filling material in goaf

    Science.gov (United States)

    Chen, W. X.; Xiao, F. K.; Guan, X. H.; Cheng, Y.; Shi, X. P.; Liu, S. M.; Wang, W. W.

    2018-01-01

    As the process of urbanization accelerated, resulting in a large number of abandoned fly ash and construction waste, which have occupied the farmland and polluted the environment. In this paper, a large number of construction waste and abandoned fly ash are mixed into the filling material in goaf, the best formula of the filling material which containing a large amount of abandoned fly ash and construction waste is obtained, and the performance of the filling material is analyzed. The experimental results show that the cost of filling material is very low while the performance is very good, which have a good prospect in goaf.

  14. Computed tomography assessment of the efficiency of different techniques for removal of root canal filling material

    International Nuclear Information System (INIS)

    Dall'agnol, Cristina; Barletta, Fernando Branco; Hartmann, Mateus Silveira Martins

    2008-01-01

    This study evaluated the efficiency of different techniques for removal of filling material from root canals, using computed tomography (CT). Sixty mesial roots from extracted human mandibular molars were used. Root canals were filled and, after 6 months, the teeth were randomly assigned to 3 groups, according to the root-filling removal technique: Group A - hand instrumentation with K-type files; Group B - reciprocating instrumentation with engine-driven K-type files; and Group C rotary instrumentation with engine-driven ProTaper system. CT scans were used to assess the volume of filling material inside the root canals before and after the removal procedure. In both moments, the area of filling material was outlined by an experienced radiologist and the volume of filling material was automatically calculated by the CT software program. Based on the volume of initial and residual filling material of each specimen, the percentage of filling material removed from the root canals by the different techniques was calculated. Data were analyzed statistically by ANOVA and chi-square test for linear trend (α=0.05). No statistically significant difference (p=0.36) was found among the groups regarding the percent means of removed filling material. The analysis of the association between the percentage of filling material removal (high or low) and the proposed techniques by chi-square test showed statistically significant difference (p=0.015), as most cases in group B (reciprocating technique) presented less than 50% of filling material removed (low percent removal). In conclusion, none of the techniques evaluated in this study was effective in providing complete removal of filling material from the root canals. (author)

  15. Computed tomography assessment of the efficiency of different techniques for removal of root canal filling material

    Energy Technology Data Exchange (ETDEWEB)

    Dall' agnol, Cristina; Barletta, Fernando Branco [Lutheran University of Brazil, Canoas, RS (Brazil). Dental School. Dept. of Dentistry and Endodontics]. E-mail: fbarletta@terra.com.br; Hartmann, Mateus Silveira Martins [Uninga Dental School, Passo Fundo, RS (Brazil). Postgraduate Program in Dentistry

    2008-07-01

    This study evaluated the efficiency of different techniques for removal of filling material from root canals, using computed tomography (CT). Sixty mesial roots from extracted human mandibular molars were used. Root canals were filled and, after 6 months, the teeth were randomly assigned to 3 groups, according to the root-filling removal technique: Group A - hand instrumentation with K-type files; Group B - reciprocating instrumentation with engine-driven K-type files; and Group C rotary instrumentation with engine-driven ProTaper system. CT scans were used to assess the volume of filling material inside the root canals before and after the removal procedure. In both moments, the area of filling material was outlined by an experienced radiologist and the volume of filling material was automatically calculated by the CT software program. Based on the volume of initial and residual filling material of each specimen, the percentage of filling material removed from the root canals by the different techniques was calculated. Data were analyzed statistically by ANOVA and chi-square test for linear trend ({alpha}=0.05). No statistically significant difference (p=0.36) was found among the groups regarding the percent means of removed filling material. The analysis of the association between the percentage of filling material removal (high or low) and the proposed techniques by chi-square test showed statistically significant difference (p=0.015), as most cases in group B (reciprocating technique) presented less than 50% of filling material removed (low percent removal). In conclusion, none of the techniques evaluated in this study was effective in providing complete removal of filling material from the root canals. (author)

  16. Density of loose-fill insulation material exposed to cyclic humidity conditions

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    the granulated loose-fill material is exposed to a climate that is characterised as cyclic humidity conditions (a constant temperature and a relative humidity alternating between two predetermined constant relative humidity levels). A better understanding of the behaviour of granulated loose-fill material...

  17. Neutralization of Aerosolized Bio-Agents by Filled Nanocomposite Materials through Thermal and Chemical Inactivation Mechanisms

    Science.gov (United States)

    2016-06-01

    Bio -agents by Filled Nanocomposite Materials through Thermal and Chemical Inactivation Mechanisms Distribution Statement A. Approved for public...of Cincinnati Project Title: Neutralization of Aerosolized Bio -agents by Filled Nanocomposite Materials through Thermal and Chemical Inactivation...fire ball, where they will not effectively interact with any viable bio -aerosol. 1.1.4. Conclusions Cryo-milling is necessary to achieve a

  18. Radiopacity of bulk fill flowable resin composite materials

    African Journals Online (AJOL)

    2015-08-23

    Aug 23, 2015 ... 2017 Nigerian Journal of Clinical Practice | Published by Wolters Kluwer - Medknow. Abstract ... one of the latest trends in dental materials research is the ..... Geneva: International Organisation for Standardization; 2000. 13.

  19. The presence of antimony in various dental filling materials

    International Nuclear Information System (INIS)

    Molokhia, Anat; Combe, E.C.; Lilley, J.D.

    1985-01-01

    Antimony was determined in a number of non-metallic dental materials currently used for tooth restoration. The method applied was instrumental neutron activation analysis. The concentration of antimony in some of the brands tested was found to be as high as 900 fold that in the normal hard dental tissues. (author)

  20. Chemical properties of gutta-percha endodontic filling material: investigation of five commercial brands

    International Nuclear Information System (INIS)

    Silva Junior, Joao Batista A.; Paula, Regina C.M.; Feitosa, Judith P.A.; Gurgel Filho, Eduardo; Teixeira, Fabricio B

    2001-01-01

    Chemical composition e thermal stability of five brands of gutta-percha endodontic filling material were investigated. Samples with higher amount of organic materials possess higher thermal stability. Investigation of gutta-percha polymer extracted from the endodontic filling by IR and NMR shows that the polymer is predominantly trans-polyisoprene. The thermal stability and molar mass were similar for four brands, however the 'Tanari' brand has got lower molar mass value than the other ones. (author)

  1. Designing strip footing foundations using expanded polystyrene (EPS) as fill material

    DEFF Research Database (Denmark)

    Psarropoulos, Prodromos; Zania, Varvara; Spyrakos, Konstantinos

    2010-01-01

    One of the modern uses of expanded polystyrene (EPS) is in strip footings as fill material. The current study investigates the effect of the geofoam filling in the static and seismic design of the base slab founded on strip footings. For this purpose the finite element method is employed, and three......-dimensional as well as two-dimensional parametric analyses are conducted taking into account static and seismic loading conditions. The interaction of the soil–geofoam–foundation system is taken into consideration. The use of EPS as fill material in foundation systems is proven to be not only technically but also...

  2. Determining the apical terminus of root-end resected teeth using three modern apex locators: a comparative ex vivo study.

    Science.gov (United States)

    ElAyouti, A; Kimionis, I; Chu, A-L; Löst, C

    2005-11-01

    To assess ex vivo the accuracy of various electronic apex locators in locating the apical terminus of root-end resected teeth. Ninety extracted human posterior teeth (182 root canals) were prepared to a minimum size of 40 and filled with gutta-percha and sealer. After resection of the apical 3 mm of the root, the root canal filling was removed using HERO rotary instruments. The size of the root canal at the apical terminus after removal of the filling ranged from size 50 to 90. The root canal length to the apical terminus was determined using 3 apex locators (Root ZX, Raypex4 and Apex Pointer). A new mounting model that utilized a micrometer was used to perform the measurements and to visually determine the actual position of the apical terminus. The frequency of locating the apical terminus and the corresponding 95% confidence interval (CI) were calculated. Additionally, the coefficient of repeatability of each apex locator and the limits of inter-operator agreement were determined. All apex locators showed an acceptable repeatability (0.02-0.03 mm coefficient of repeatability) and narrow limits of inter-operator agreement (+0.07 and -0.07 mm). The accuracy of determining the apical terminus within 1 mm in the root canal was as follows: Root ZX 90% (164/182 root-canals) [95%CI: 86-94%], Raypex4 74% (135/182 root-canals) [95%CI: 68-80%], and Apex Pointer 71% (129/182 root canals) [95%CI: 65-77%]. No over-instrumentation resulted when the Root ZX device was used. In contrast, using the Raypex4 or the Apex Pointer device resulted in over-instrumentation in 8 of 182 root canals (4%). Under the conditions of this study all three apex locators were able to detect the apical terminus of root-end resected teeth with an acceptable range. The Root ZX device was the most accurate without over-instrumentation of the root canals.

  3. 3D Analysis of D-RaCe and Self-Adjusting File in Removing Filling Materials from Curved Root Canals Instrumented and Filled with Different Techniques

    Directory of Open Access Journals (Sweden)

    Neslihan Simsek

    2014-01-01

    Full Text Available The aim of this study was to compare the efficacy of D-RaCe files and a self-adjusting file (SAF system in removing filling material from curved root canals instrumented and filled with different techniques by using microcomputed tomography (micro-CT. The mesial roots of 20 extracted mandibular first molars were used. Root canals (mesiobuccal and mesiolingual were instrumented with SAF or Revo-S. The canals were then filled with gutta-percha and AH Plus sealer using cold lateral compaction or thermoplasticized injectable techniques. The root fillings were first removed with D-RaCe (Step 1, followed by Step 2, in which a SAF system was used to remove the residual fillings in all groups. Micro-CT scans were used to measure the volume of residual filling after root canal filling, reinstrumentation with D-RaCe (Step 1, and reinstrumentation with SAF (Step 2. Data were analyzed using Wilcoxon and Kruskal-Wallis tests. There were no statistically significant differences between filling techniques in the canals instrumented with SAF (P=0.292 and Revo-S (P=0.306. The amount of remaining filling material was similar in all groups (P=0.363; all of the instrumentation techniques left filling residue inside the canals. However, the additional use of SAF was more effective than using D-RaCe alone.

  4. Effectiveness of rotatory and reciprocating movements in root canal filling material removal

    Directory of Open Access Journals (Sweden)

    Emmanuel João Nogueira Leal SILVA

    2015-01-01

    Full Text Available The purpose of this study was to compare the efficacy of reciprocating and rotary techniques for removing gutta-percha and sealer from root canals. Forty straight and oval single-rooted premolars were prepared up to size 30, filled with gutta-percha and sealer, and then randomly allocated to two experimental retreatment groups: ProTaper Retreatment System (PTRS and WaveOne System (WS. Procedural errors, time of retreatment and apically extruded material were recorded for all the roots. The roots were radiographed after retreatment. The percentage of residual material was calculated using image analysis software. The data were analyzed by Kolmogorov-Smirnov and t tests, with a significance level set at 5%. No system completely removed the root filling material from the root canal. No significant differences were observed between the systems, in terms of residual filling material in any tested third (p > 0.05. WS was faster in removing filling material than PTRS (p< 0.05. Extrusion was observed in 4 cases in PTRS and in 5 cases in WS. No procedural errors were observed in either group. It can be concluded that although no differences were observed in the efficacy of PTRS and WS for removing root filling material, WS was faster than PTRS.

  5. Efficacy of ProTaper universal retreatment files in removing filling materials during root canal retreatment.

    Science.gov (United States)

    Giuliani, Valentina; Cocchetti, Roberto; Pagavino, Gabriella

    2008-11-01

    The aim of this study was to evaluate the efficacy of the ProTaper Universal System rotary retreatment system and of Profile 0.06 and hand instruments (K-file) in the removal of root filling materials. Forty-two extracted single-rooted anterior teeth were selected. The root canals were enlarged with nickel-titanium (NiTi) rotary files, filled with gutta-percha and sealer, and randomly divided into 3 experimental groups. The filling materials were removed with solvent in conjunction with one of the following devices and techniques: the ProTaper Universal System for retreatment, ProFile 0.06, and hand instruments (K-file). The roots were longitudinally sectioned, and the image of the root surface was photographed. The images were captured in JPEG format; the areas of the remaining filling materials and the time required for removing the gutta-percha and sealer were calculated by using the nonparametric one-way Kruskal-Wallis test and Tukey-Kramer tests, respectively. The group that showed better results for removing filling materials was the ProTaper Universal System for retreatment files, whereas the group of ProFile rotary instruments yielded better root canal cleanliness than the hand instruments, even though there was no statistically significant difference. The ProTaper Universal System for retreatment and ProFile rotary instruments worked significantly faster than the K-file. The ProTaper Universal System for retreatment files left cleaner root canal walls than the K-file hand instruments and the ProFile Rotary instruments, although none of the devices used guaranteed complete removal of the filling materials. The rotary NiTi system proved to be faster than hand instruments in removing root filling materials.

  6. RECOMMENDED FOUNDATION FILL MATERIALS CONSTRUCTION STANDARD OF THE FLORIDA RADON RESEARCH PROGRAM

    Science.gov (United States)

    The report summarizes the technical basis for a recommended foundation fill materials standard for new construction houses in Florida. he radon-control construction standard was developed by the Florida Radon Research Program (FRRP). ill material standards are formulated for: (1)...

  7. Setting of loose-fill insulation materials in walls; Saetningsfri indblaesning af loesfyldsisolering i vaegge

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, T.V.

    2001-07-01

    The report describes material behaviour, which significantly influences the settling of loose-fill insulation materials. The specific application presented here is loose-fill insulation material injected in walls as thermal insulation. The physical formulation of the issue to be discussed is that the mass is kept in position in the cavity by frictional forces, which counteracts the settling but complicates injection. The purpose of this study is to investigate whether there is a possibility that decreased friction will be able to release settling. Cellulose loose-fill material injected in a 0.1 m thick and 1 m wide gypsum wall with a minimum density of 48 kg/m3 was found not to settle if kept at a constant relative humidity, RH 50 %. A minimum density of 53 kg/m3 is necessary if the thickness of the wall is increased from 0.1 m to 0.3 m. If changing the constant environment from RH 50 % to RH 80 % a minimum density of 63 kg/m3 is necessary. Furthermore, results so far show that cellulose loose-fill material spread on the attic floor will have a density after settling of 48 kg /M3 for a constant RH 50 %, corresponding to 43 kg/m3 dry material. The results were found by using a model and tests. (au)

  8. The choice of iron-containing filling for composite radioprotective material

    Science.gov (United States)

    Matyukhin, P. V.

    2018-03-01

    The paper presents the data the composition of modern composite building materials including materials which in addition to high physical-mechanical have radio-protective properties. The article presents infrared researches and differential thermal data of fine-grained magnetite and hematite beneficiated iron-ore concentrates. The choice of the most suitable filling for new composite radio-protective building material engineering and development was made basing on the magnetite and hematite data presented in the paper.

  9. Rheology of Emulsion-Filled Gels Applied to the Development of Food Materials

    Directory of Open Access Journals (Sweden)

    Ivana M. Geremias-Andrade

    2016-08-01

    Full Text Available Emulsion-filled gels are classified as soft solid materials and are complex colloids formed by matrices of polymeric gels into which emulsion droplets are incorporated. Several structural aspects of these gels have been studied in the past few years, including their applications in food, which is the focus of this review. Knowledge of the rheological behavior of emulsion-filled gels is extremely important because it can measure interferences promoted by droplets or particle inclusion on the textural properties of the gelled systems. Dynamic oscillatory tests, more specifically, small amplitude oscillatory shear, creep-recovery tests, and large deformation experiments, are discussed in this review as techniques present in the literature to characterize rheological behavior of emulsion-filled gels. Moreover, the correlation of mechanical properties with sensory aspects of emulsion-filled gels appearing in recent studies is discussed, demonstrating the applicability of these parameters in understanding mastication processes.

  10. Construction of a test embankment using a sand-tire shred mixture as fill material.

    Science.gov (United States)

    Yoon, Sungmin; Prezzi, Monica; Siddiki, Nayyar Zia; Kim, Bumjoo

    2006-01-01

    Use of tire shreds in construction projects, such as highway embankments, is becoming an accepted way of beneficially recycling scrap tires. However, in the last decade there was a decline in the use of pure tire shreds as fill materials in embankment construction, as they are susceptible to fire hazards due to the development of exothermic reactions. Tire shred-sand mixtures, on the other hand, were found to be effective in inhibiting exothermic reactions. When compared with pure tire shreds, tire shred-sand mixtures are less compressible and have higher shear strength. However, the literature contains limited information on the use of tire shred-soil mixtures as a fill material. The objectives of this paper are to discuss and evaluate the feasibility of using tire shred-sand mixtures as a fill material in embankment construction. A test embankment constructed using a 50/50 mixture, by volume, of tire shreds and sand was instrumented and monitored to: (a) determine total and differential settlements; (b) evaluate the environmental impact of the embankment construction on the groundwater quality due to leaching of fill material; and (c) study the temperature variation inside the embankment. The findings in this research indicate that mixtures of tire shreds and sand are viable materials for embankment construction.

  11. Cleaning efficacy of reciprocal and rotary systems in the removal of root canal filling material

    Science.gov (United States)

    Koçak, Mustafa Murat; Koçak, Sibel; Türker, Sevinç Aktemur; Sağlam, Baran Can

    2016-01-01

    Aim: The aim of this study was to compare the efficacy of hand file, nickel titanium rotary instrument, and two reciprocating instruments for removing gutta-percha and sealer from the root canals. Materials and Methods: Eighty-eight mandibular premolar teeth were used. The root canals were shaped and filled with gutta-percha and a resin-based sealer. The specimens were divided into four groups according to the technique by which the root filling material was removed: Group 1 — Wave One; Group 2 — Reciproc; Group 3 — ProTaper; and Group 4 — Gates-Glidden burs and stainless steel hand file. Then teeth were split longitudinally and photographed. The images were transferred to a computer. The ratio of remaining filling material to the root canal periphery was calculated with the aid of ImageJ software. Statistical analysis was performed using Kruskal–Wallis and Mann–Whitney tests. Results: A significant difference was found among all groups (P hand file. Conclusion: The reciprocating files were found to be significantly more effective in removing the filling material from the canal walls compared to the rotational file and hand file. PMID:27099429

  12. Dental Glass Ionomer Cements as Permanent Filling Materials? – Properties, Limitations and Future Trends

    Directory of Open Access Journals (Sweden)

    Ulrich Lohbauer

    2009-12-01

    Full Text Available Glass ionomer cements (GICs are clinically attractive dental materials that have certain unique properties that make them useful as restorative and luting materials. This includes adhesion to moist tooth structures and base metals, anticariogenic properties due to release of fluoride, thermal compatibility with tooth enamel, biocompatibility and low toxicity. The use of GICs in a mechanically loaded situation, however, has been hampered by their low mechanical performance. Poor mechanical properties, such as low fracture strength, toughness and wear, limit their extensive use in dentistry as a filling material in stress-bearing applications. In the posterior dental region, glass ionomer cements are mostly used as a temporary filling material. The requirement to strengthen those cements has lead to an ever increasing research effort into reinforcement or strengthening concepts.

  13. Thermal properties of lauric acid filled in carbon nanotubes as shape-stabilized phase change materials.

    Science.gov (United States)

    Feng, Yanhui; Wei, Runzhi; Huang, Zhi; Zhang, Xinxin; Wang, Ge

    2018-03-14

    Carbon nanotubes (CNTs) filled with lauric acid (LA) as a kind of shape-stabilized phase change material were prepared and their structures and phase change properties were characterized. The results showed that the melting point and latent heat of LA confined in carbon nanotubes were lower than those of the bulk material, and both decrease as the diameters of CNTs and the filling ratios of LA decrease. Molecular dynamics (MD) simulations indicated that LA molecules form a liquid layer near pore walls and crystallize at the pore center. When the LA filling ratio was reduced to a certain value, all LA molecules were attached to the inner walls of CNTs, hindering their crystallization. A linear relationship between the melting temperature shift and structural properties was obtained based on the modified Gibbs-Thomson equation, which gives a reliable interpretation of the size effect of nanochannels in phase change materials. We also found that the thermal conductivity of the composite CNTs/LA was four times larger than that of pure LA. This study will provide insights into the design of novel composite phase change materials with better thermal properties by the selection of suitable porous materials and tailoring their pore structures.

  14. Experimental Study and Application of Inorganic Solidified Foam Filling Material for Coal Mines

    Directory of Open Access Journals (Sweden)

    Hu Wen

    2017-01-01

    Full Text Available Spontaneous combustion of residual coal in a gob due to air leakage poses a major risk to mining safety. Building an airtight wall is an effective measure for controlling air leakage. A new type of inorganic solidified foam-filled material was developed and its physical and chemical properties were analyzed experimentally. The compressive strength of this material increased with the amount of sulphoaluminate cement. With an increasing water–cement ratio, the initial setting time was gradually extended while the final setting time firstly shortened and then extended. The change in compressive strength had the opposite tendency. Additionally, as the foam expansion ratio increased, the solidification time tended to decrease but the compressive strength remained approximately constant. With an increase in foam production, the solidification time increased and the compressive strength decreased exponentially. The results can be used to determine the optimal material ratios of inorganic solidified foam-filled material for coal mines, and filling technology for an airtight wall was designed. A field application of the new material demonstrated that it seals crossheadings tightly, leaves no fissures, suppresses air leakage to the gob, and narrows the width of the spontaneous combustion and heat accumulation zone.

  15. Shear bond strength of bulk-fill and nano-restorative materials to dentin.

    Science.gov (United States)

    Colak, Hakan; Ercan, Ertugrul; Hamidi, Mehmet Mustafa

    2016-01-01

    Bulk-fill composite materials are being developed for preparation depths of up to 4 mm in an effort to simplify and improve the placement of direct composite posterior restorations. The aim of our study was to compare shear-bond strength of bulk-fill and conventional posterior composite resins. In this study, 60 caries free extracted human molars were used and sectioned parallel to occlusal surface to expose midcoronal dentin. The specimens were randomly divided into four groups. Total-etch dentine bonding system (Adper Scotchbond 1XT, 3M ESPE) was applied to dentin surface in all the groups to reduce variability in results. Then, dentine surfaces covered by following materials. Group I: SonicFill Bulk-Fill, Group II: Tetric EvoCeram (TBF), Group III: Herculite XRV Ultra, and Group IV: TBF Bulk-Fill, 2 mm × 3 mm cylindrical restorations were prepared by using application apparatus. Shear bond testing was measured by using a universal testing machine. Kruskal-Wallis and Mann-Whitney U-tests were performed to evaluate the data. The highest value was observed in Group III (14.42 ± 4.34) and the lowest value was observed in Group IV (11.16 ± 2.76) and there is a statistically significant difference between these groups (P = 0.046). However, there is no statistically significant difference between the values of other groups. In this study, Group III was showed higher strength values. There is a need for future studies about long-term bond strength and clinical success of these adhesive and bulk-fill systems.

  16. Comparison of Endoflas and Zinc oxide Eugenol as root canal filling materials in primary dentition

    Directory of Open Access Journals (Sweden)

    Nivedita Rewal

    2014-01-01

    Full Text Available Background: Zinc oxide eugenol has long been the material of choice of pediatric dentists worldwide, although it fails to meet the ideal requirements of root canal filling material for primary teeth. Endoflas, a mixture of zinc oxide eugenol, calcium hydroxide, and iodoform, can be considered to be an effective root canal filling material in primary teeth as compared with zinc oxide eugenol. This study was carried out to compare zinc oxide eugenol with endoflas for pulpectomy in primary dentition. Aim: The objective of the study was to compare clinically and radiographically success rates of zinc oxide eugenol with endoflas for the root canal filling of primary teeth at 3, 6, and 9 months. Design: Fifty primary molars were included in the study with 26 teeth in Group I (Endoflas and 24 in Group II (zinc oxide eugenol. A single visit pulpectomy was carried out. Results: The overall success rate of zinc oxide eugenol was 83% whereas 100% success was found in the case of endoflas. The obtained results were compiled and subjected to statistical analysis using the chi-square test. The difference in the success rate between the two was statistically significant (P < 0.05. Conclusion: Endoflas has shown to have better results than zinc oxide eugenol. It should therefore be the material of choice for root canal treatment in deciduous dentition.

  17. Evaluation of root-end microcrack formation following retropreparation using different ultrasonic instruments

    International Nuclear Information System (INIS)

    AlKahtani, Ahmed

    2009-01-01

    This study evaluated differences among various ultrasonic instruments in the development of root-end cracks following retropreparation of endodontically treated teeth. Three ultrasonic tips were compared: stainless steel, zirconium nitride and diamond. Fifty-seven single rooted extracted teeth were cleaned, shaped and obturated. Their crowns were removed. A 3 mm resection of the root-tip was completed using a straight fissure bur. The teeth were examined under a light microscope. The teeth that developed cracks after resection were discarded. The teeth were divided into three groups of 19 teeth each and a retropreparation was completed with one of the ultrasonic tips for each group. Teeth were again examined under a light microscope. The photomicrographs of the teeth before and after were compared. Examination of the specimens revealed that in the stainless steel group, 26% (5/19) of teeth developed cracks, in the zirconium nitride group, 10.5% (2/19) of teeth developed cracks and in the diamond group, 10.5% (2/19) of teeth developed cracks. The differences in crack formation among the three groups were not statistically significant. The results of the study suggested that more cracks may be evident microscopically in root-ends prepared with stainless steel ultrasonic instruments although this was not statistically significant. (author)

  18. Air-Filled Nanopore Based High-Performance Thermal Insulation Materials

    OpenAIRE

    Gangåssæter, Haakon Fossen; Jelle, Bjørn Petter; Alex Mofid, Sohrab; Gao, Tao

    2017-01-01

    State-of-the-art thermal insulation solutions like vacuum insulation panels (VIP) and aerogels have low thermal conductivity, but their drawbacks may make them unable to be the thermal insulation solutions that will revolutionize the building industry regarding energy-efficient building envelopes. Nevertheless, learning from these materials may be crucial to make new and novel high-performance thermal insulation products. This study presents a review on the state-of-the-art air-filled thermal...

  19. Effect of bulk-fill base material on fracture strength of root-filled teeth restored with laminate resin composite restorations.

    Science.gov (United States)

    Taha, N A; Maghaireh, G A; Ghannam, A S; Palamara, J E

    2017-08-01

    To evaluate the effect of using a bulk-fill flowable base material on fracture strength and fracture patterns of root-filled maxillary premolars with MOD preparations restored with laminate restorations. Fifty extracted maxillary premolars were selected for the study. Standardized MOD cavities with endodontic treatment were prepared for all teeth, except for intact control. The teeth were divided randomly into five groups (n=10); (Group 1) sound teeth, (Group 2) unrestored teeth; (Group 3) MOD cavities with Vitrebond base and resin-based composite (Ceram. X One Universal); (Group 4) MOD cavities with 2mm GIC base (Fuji IX GP) and resin-based composite (Ceram. X One Universal) open laminate, (Group 5) MOD cavities were restored with 4mm of bulk-fill flowable base material (SDR) and resin-based composite (Ceram. X One Universal). All teeth were thermocycled and subjected to a 45° ramped oblique load in a universal testing machine. Fracture load and fracture patterns were recorded. Data were analyzed using one-way ANOVA and Dunnett's T3 test. Restoration in general increased the fracture strength compared to unrestored teeth. The fracture strength of group 5 (bulk-fill) was significantly higher than the fracture strength of the GIC laminate groups and not significantly different from the intact teeth (355±112N, P=0.118). The type of failure was unfavorable for most of the groups, with the majority being mixed failures. The use of a bulk-fill flowable base material significantly increased the fracture strength of extracted root-filled teeth with MOD cavities; however it did not improve fracture patterns to more favorable ones. Investigating restorative techniques that may improve the longevity of root-filled premolar teeth restored with direct resin restorations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Development of a novel filling technique. Loading bulk particulate materials into tankers or processes

    Energy Technology Data Exchange (ETDEWEB)

    Farnish, R.J.; Berry, R.; Bradley, M. [Greenwich Univ., Chatham Maritime, Kent (United Kingdom). Wolfson Centre for Bulk Solids Handling Technology

    2008-07-01

    The majority of industrial dosing or filling operations demand high filling rates and often good repeatability of discharges. For coarse, free-flowing materials the issues of obtaining a high degree of filling efficiency are substantially less challenging than for less free-flowing or cohesive bulk particulates. Typical equipment arrangements for achieving a controlled (often dual rate) discharge of particles into a relatively small capacity container (flask, sack or big bag) often rely on either a mechanical extraction of material from a buffer (screw feeders) or the manipulation of a constricting arrangement to achieve a turn down in discharge rate. Where less freeflowing or very fine particles are being handled, the introduction of air into the powder is invariably used to modify the bulk condition of the material to a condition where discharge can be initiated and supported (typical examples being powder feed to an impeller packer, or discharge of powder into a rail or road wagon). This article will therefore report on some recent research that has been undertaken by The Wolfson Centre for Bulk Solids Handling Technology, University of Greenwich. (orig.)

  1. Dark localized structures in a cavity filled with a left-handed material

    International Nuclear Information System (INIS)

    Tlidi, Mustapha; Kockaert, Pascal; Gelens, Lendert

    2011-01-01

    We consider a nonlinear passive optical cavity filled with left-handed and right-handed materials and driven by a coherent injected beam. We assume that both left-handed and right-handed materials possess a Kerr focusing type of nonlinearity. We show that close to the zero-diffraction regime, high-order diffraction allows us to stabilize dark localized structures in this device. These structures consist of dips in the transverse profile of the intracavity field and do not exist without high-order diffraction. We analyze the snaking bifurcation diagram associated with these structures. Finally, a realistic estimation of the model parameters is provided.

  2. Soft Chemistry, Coloring and Polytypism in Filled Tetrahedral Semiconductors: Toward Enhanced Thermoelectric and Battery Materials.

    Science.gov (United States)

    White, Miles A; Medina-Gonzalez, Alan M; Vela, Javier

    2018-03-12

    Filled tetrahedral semiconductors are a rich family of compounds with tunable electronic structure, making them ideal for applications in thermoelectrics, photovoltaics, and battery anodes. Furthermore, these materials crystallize in a plethora of related structures that are very close in energy, giving rise to polytypism through the manipulation of synthetic parameters. This Minireview highlights recent advances in the solution-phase synthesis and nanostructuring of these materials. These methods enable the synthesis of metastable phases and polytypes that were previously unobtainable. Additionally, samples synthesized in solution phase have enhanced thermoelectric performance due to their decreased grain size. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Retention of uranium(VI) by laumontite, a fracture-filling material of granite

    International Nuclear Information System (INIS)

    Baik, M.H.; Lee, S.Y.; Shon, W.J.

    2009-01-01

    Retention of U(VI) by laumontite, a fracture-filling material of granite as investigated by conducting dynamic and batch sorption experiments in a love-box using a granite core with a natural fracture. The hydrodynamic properties of the granite core were obtained from the elution curve of a on-sorbing tracer, Br - . The elution curve of U(VI) showed a similar behavior to Br - . This reveals that the retention of U(VI) by the fracture-filling material was not significant when migrating through the fracture at a given condition. From the dynamic sorption experiment, the retardation factor R a and the distribution coefficient K a of U(VI) were obtained as about 2.9 and 0.16 cm, respectively. The distribution coefficient K d ) of U(VI) onto laumontite obtained by conducting a batch sorption experiment resulted in a small value of 2.3±0.5 mL/g. This low K d value greed with the result of the dynamic sorption experiment. For the distribution of uranium on the granite surface investigated by an X-ray image mapping, the fracture region filled with laumontite showed a relatively lower content of uranium compared to the surrounding granite surface. Thus, the low retention of U(VI) by the fracture-filling material can be explained by following two mechanisms. One is that U(VI) exists as anionic uranyl hydroxides or uranyl carbonates at a given groundwater condition and the other is the remarkably low sorption capacity of the laumontite for U(VI). author)

  4. Microstructure and wettability of root canal dentine and root canal filling materials after different chemical irrigation

    Energy Technology Data Exchange (ETDEWEB)

    Antonijevic, Djordje; Milovanovic, Petar [Laboratory for Anthropology, Institute for Anatomy, Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Brajkovic, Denis [Department of Dentistry, Faculty of Medical Sciences, University of Kragujevac, Kragujevac (Serbia); Ilic, Dragan [Department of Restorative Medicine, School of Dental Medicine, University of Belgrade, Belgrade (Serbia); Hahn, Michael; Amling, Michael [Department of Osteology and Biomechanics (IOBM), University Medical Center Hamburg-Eppendorf, Lottestr. 55A, 22529 Hamburg (Germany); Rakocevic, Zlatko [Laboratory for Atomic Physics, Institute for Nuclear Science “Vinca”, University of Belgrade, Belgrade (Serbia); Djuric, Marija [Laboratory for Anthropology, Institute for Anatomy, Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Busse, Björn, E-mail: b.busse@uke.uni-hamburg.de [Department of Osteology and Biomechanics (IOBM), University Medical Center Hamburg-Eppendorf, Lottestr. 55A, 22529 Hamburg (Germany)

    2015-11-15

    Graphical abstract: - Highlights: • Different irrigation solutions and disinfectants were used for treatment of root canal dentine and gutta-percha points. • Materials surface characteristics were assessed using quantitative backscattered electron imaging, reference point indentation, and contact angle analyzer. • The most significant differences in mineralization, indentation, and adhesive outcomes were observed after ethylenediaminetetraacetic acid treatment. • Irrigation solutions confer to superior sealing ability of endodontic filling materials. • Micromechanical characteristics of dentine after irrigation are considerable reduced. - Abstract: The objective of this study was to determine the effects of various irrigation solutions on root canal dentine and gutta-percha surface properties. In addition, the effects of disinfectant chemicals on the wettability and surface morphological properties of the filling materials were evaluated. Ethylenediaminetetraacetic acid (EDTA), citric acid, and ozone were employed as irrigation solutions for dentine and gutta-percha treatment. Thereafter, the samples’ microstructure, degree of mineralization, and mechanical properties were assessed by means of quantitative backscattered electron imaging (qBEI) and reference point indentation (RPI). A contact angle analyzer was used to measure adhesion on the tested materials. Here, EDTA had the most significant affect on both the mechanical properties and the adhesive behavior of dentine. Citric acid did not affect dentine wettability, whereas the indentation properties and the mineralization were reduced. Similar effects were observed when ozone was used. The dentinal tubules were significantly widened in citric acid compared to the ozone group. EDTA causes considerable micromechanical surface alteration of dentine and gutta-percha, but represents the best option in clinical cases where a high adhesiveness of the filling materials is desired.

  5. Hybrid waste filler filled bio-polymer foam composites for sound absorbent materials

    Science.gov (United States)

    Rus, Anika Zafiah M.; Azahari, M. Shafiq M.; Kormin, Shaharuddin; Soon, Leong Bong; Zaliran, M. Taufiq; Ahraz Sadrina M. F., L.

    2017-09-01

    Sound absorption materials are one of the major requirements in many industries with regards to the sound insulation developed should be efficient to reduce sound. This is also important to contribute in economically ways of producing sound absorbing materials which is cheaper and user friendly. Thus, in this research, the sound absorbent properties of bio-polymer foam filled with hybrid fillers of wood dust and waste tire rubber has been investigated. Waste cooking oil from crisp industries was converted into bio-monomer, filled with different proportion ratio of fillers and fabricated into bio-polymer foam composite. Two fabrication methods is applied which is the Close Mold Method (CMM) and Open Mold Method (OMM). A total of four bio-polymer foam composite samples were produce for each method used. The percentage of hybrid fillers; mixture of wood dust and waste tire rubber of 2.5 %, 5.0%, 7.5% and 10% weight to weight ration with bio-monomer. The sound absorption of the bio-polymer foam composites samples were tested by using the impedance tube test according to the ASTM E-1050 and Scanning Electron Microscope to determine the morphology and porosity of the samples. The sound absorption coefficient (α) at different frequency range revealed that the polymer foam of 10.0 % hybrid fillers shows highest α of 0.963. The highest hybrid filler loading contributing to smallest pore sizes but highest interconnected pores. This also revealed that when highly porous material is exposed to incident sound waves, the air molecules at the surface of the material and within the pores of the material are forced to vibrate and loses some of their original energy. This is concluded that the suitability of bio-polymer foam filled with hybrid fillers to be used in acoustic application of automotive components such as dashboards, door panels, cushion and etc.

  6. Microstructure and wettability of root canal dentine and root canal filling materials after different chemical irrigation

    International Nuclear Information System (INIS)

    Antonijevic, Djordje; Milovanovic, Petar; Brajkovic, Denis; Ilic, Dragan; Hahn, Michael; Amling, Michael; Rakocevic, Zlatko; Djuric, Marija; Busse, Björn

    2015-01-01

    Graphical abstract: - Highlights: • Different irrigation solutions and disinfectants were used for treatment of root canal dentine and gutta-percha points. • Materials surface characteristics were assessed using quantitative backscattered electron imaging, reference point indentation, and contact angle analyzer. • The most significant differences in mineralization, indentation, and adhesive outcomes were observed after ethylenediaminetetraacetic acid treatment. • Irrigation solutions confer to superior sealing ability of endodontic filling materials. • Micromechanical characteristics of dentine after irrigation are considerable reduced. - Abstract: The objective of this study was to determine the effects of various irrigation solutions on root canal dentine and gutta-percha surface properties. In addition, the effects of disinfectant chemicals on the wettability and surface morphological properties of the filling materials were evaluated. Ethylenediaminetetraacetic acid (EDTA), citric acid, and ozone were employed as irrigation solutions for dentine and gutta-percha treatment. Thereafter, the samples’ microstructure, degree of mineralization, and mechanical properties were assessed by means of quantitative backscattered electron imaging (qBEI) and reference point indentation (RPI). A contact angle analyzer was used to measure adhesion on the tested materials. Here, EDTA had the most significant affect on both the mechanical properties and the adhesive behavior of dentine. Citric acid did not affect dentine wettability, whereas the indentation properties and the mineralization were reduced. Similar effects were observed when ozone was used. The dentinal tubules were significantly widened in citric acid compared to the ozone group. EDTA causes considerable micromechanical surface alteration of dentine and gutta-percha, but represents the best option in clinical cases where a high adhesiveness of the filling materials is desired.

  7. Discrimination of high-Z materials in concrete-filled containers using muon scattering tomography

    Science.gov (United States)

    Frazão, L.; Velthuis, J.; Thomay, C.; Steer, C.

    2016-07-01

    An analysis method of identifying materials using muon scattering tomography is presented, which uses previous knowledge of the position of high-Z objects inside a container and distinguishes them from similar materials. In particular, simulations were performed in order to distinguish a block of Uranium from blocks of Lead and Tungsten of the same size, inside a concrete-filled drum. The results show that, knowing the shape and position from previous analysis, it is possible to distinguish 5 × 5 × 5 cm3 blocks of these materials with about 4h of muon exposure, down to 2 × 2 × 2 cm3 blocks with 70h of data using multivariate analysis (MVA). MVA uses several variables, but it does not benefit the discrimination over a simpler method using only the scatter angles. This indicates that the majority of discrimination is provided by the angular information. Momentum information is shown to provide no benefits in material discrimination.

  8. Reactive transport of Sr, Cs and Tc through a column packed with fracture-filling material

    International Nuclear Information System (INIS)

    Cui, D.; Eriksen, T.

    1998-01-01

    The migration behaviour of the fission products 90 Sr, 137 Cs and 99 Tc in a granite fracture-groundwater system was studied in column experiments using crushed Stripa granite fracture-filling material (125-250 μm) as a sorbent. Based on breakthrough curves of Sr 2+ , Cs + , TcO 4 - and anthraquinonsulphonate, the distribution ratio K d (cm 3 /g) values for Sr 2+ and Cs + were estimated to be 1.5 and 2 respectively; non-sorbing behaviour of TcO 4 - under oxic conditions was observed. The diffusion of Sr 2+ in the material is shown to be a kinetic-controlling step in the desorption process that followed the initial leaching. Under reducing conditions, it was found that TcO 4 - was reduced to TcO 2 .nH 2 O(s) by the Fe(II)-containing fracture-filling material and Tc(IV) aq was rapidly sorbed by the material. This observation proves that the migration of technetium under reducing conditions in deep groundwater systems will not only be controlled by the solubility of TcO 2 . nH 2 O(s) and the speed of groundwater flow but also by the rapid sorption of Tc(IV) aq on all available mineral surfaces. (orig.)

  9. Opportunities of influence of plasma streams formed in IKA with continuos nor king gas filling en the surface of materials

    International Nuclear Information System (INIS)

    Useinov, B.M.; Useinova, A.M.; Amrenova, A.U.; Pusankov, S.A.; Sartin, S.A.; Virko, P.G.

    2001-01-01

    The results of the investigation of influence of plasma stream formed in IKA with continuous working gas filling on the surface of stainless steel 12X18H10T and aluminum are given in this article. It is shown here that the effect of influence of plasma stream on the surface of materials depends on the way of working gas filling. There is the comparison of influence of plasma stream formed in plasma accelerator with impulse and continuous working gas filling

  10. Filling the gaps in SCWR materials research: advanced nuclear corrosion research facilities in Hamilton

    International Nuclear Information System (INIS)

    Krausher, J.L.; Zheng, W.; Li, J.; Guzonas, D.; Botton, G.

    2011-01-01

    Research efforts on materials selection and development in support of the design of supercritical water-cooled reactors (SCWRs) have produced a considerable amount of data on corrosion, creep and other related properties. Summaries of the data on corrosion [1] and stress corrosion cracking [2] have recently been produced. As research on the SCWR advances, gaps and limitations in the published data are being identified. In terms of corrosion properties, these gaps can be seen in several areas, including: 1) the test environment, 2) the physical and chemical severity of the tests conducted as compared with likely reactor service/operating conditions, and 3) the test methods used. While some of these gaps can be filled readily using existing facilities, others require the availability of advanced test facilities for specific tests and assessments. In this paper, highlights of the new materials research facilities jointly established in Hamilton by CANMET Materials Technology Laboratory and McMaster University are presented. (author)

  11. Development and Sliding Wear Response of Epoxy Composites Filled with Coal Mine Overburden Material

    Science.gov (United States)

    Das, Prithika; Satapathy, Alok; Mishra, M. K.

    2018-03-01

    The paper reports on development and characterization of epoxy based composites filled with micro-sized mine overburden material. Coal mine overburden material is typically highly heterogeneous and is considered as waste material. For excavating each ton of coal, roughly 5 tons of overburden materials are removed and is dumped nearby occupying large space. Gainful utilization of this waste is a major challenge. In the present work, this material is used as filler materials in making a new class of epoxy matrix composites. Composites with different weight proportions of fillers (0, 10, 20, 30 and 40) wt. % are prepared by hand layup technique. Compression tests are performed as per corresponding ASTM standards to assess the compressive strength of these composites. Further, dry sliding tests are performed following ASTM G99 standards using a pin on disk machine. A design of experiment approach based on Taguchi’s L16 orthogonal arrays is adopted. Tests are performed at different sliding velocities for multiple sliding distances under varying normal loads. Specific wear rates of the composites under different test conditions are obtained. The analysis of the test results revealed that the filler content and the sliding velocity are the most predominant control factors affecting the wear rate. This work thus, opens up a new avenue for the value added utilization of coal mine overburden material.

  12. Ex vivo evaluation of coronal and apical microbial leakage of root canal - Filled with gutta-percha or Resilon/Epiphany root canal filling material

    Directory of Open Access Journals (Sweden)

    de Almeida-Gomes Fabio

    2010-01-01

    Full Text Available Objective: This ex vivo study compared coronal and apical microleakage of root canals filled with Resilon/Epiphany (RE or gutta-percha/Grossman sealer (GP, using either lateral condensation (LC or System B (SB technique. Materials and Methods: Specimens in eight experimental groups were obturated using the following materials and techniques: Groups 1 and 3 - GP and LC; groups 2 and 4 - GP and SB; groups 5 and 7 - RE and LC; groups 6 and 8 - RE and SB. Apical and coronal leakages were tested using bacterial methods. For coronal analysis, the number of days required for complete contamination of the root canals was recorded according to observation of the brain heart infusion broth turbidity for 15 weeks. For apical analysis, the teeth were cleaved and the leakage was measured at 30 days. Data were collected for each sample and analyzed statistically with the Chi-square and ANOVA tests. Results: Leakage was found in all groups. The difference between filling materials, obturation techniques, and median time of leakage was not statistically significant for coronal ( P=0.847 and apical ( P=0.5789 leakages. Conclusion: There were no differences between the different filling materials (gutta-percha/Grossman sealer and Resilon/Epiphany and obturation techniques (lateral condensation and system B technique in coronal or apical leakages.

  13. Adjustable Polyurethane Foam as Filling Material for a Novel Spondyloplasty: Biomechanics and Biocompatibility.

    Science.gov (United States)

    Jiang, Hongzhen; Sitoci-Ficici, Kerim Hakan; Reinshagen, Clemens; Molcanyi, Marek; Zivcak, Jozef; Hudak, Radovan; Laube, Thorsten; Schnabelrauch, Matthias; Weisser, Jürgen; Schäfer, Ute; Pinzer, Thomas; Schackert, Gabriele; Zhang, Xifeng; Wähler, Mario; Brautferger, Uta; Rieger, Bernhard

    2018-04-01

    To investigate the biomechanics and biocompatibility of polyurethane (PU) foam with adjustable stiffness as a filling material for a novel spondyloplasty that is designed to reduce the risk of postoperative adjacent level fractures. Sixty individual porcine lumbar vertebrae were randomly split into 4 groups: A, B, C, and D. Group A served as unmodified vertebral body controls. Groups B, C, and D consisted of hollowed vertebral bodies. Vertebrae of groups C and D were filled with adjustable PU foams of different stiffness. The compressive strength and stiffness of vertebrae from groups A-D were recorded and analyzed. 3T3 mouse fibroblasts were cultured with preformed PU foams for 4 days to test biocompatibility. The strength and stiffness of the hollowed groups were lower than in group A. However, the differences were not statistically significant between group A and group C (P > 0.05), and were obviously different between group A and group B or group D (P < 0.01 and <0.05, respectively). Moreover, the strength and stiffness after filling foams in group C or group D were significantly greater than in group B (P < 0.01 and <0.05, respectively). Live/dead staining of 3T3 cells confirmed the biocompatibility of the PU foam. The new PU foam shows adaptability regarding its stiffness and excellent cytocompatibility in vitro. The results support the clinical translation of the new PU foams as augmentation material in the development of a novel spondyloplasty. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Tanks 18 And 19-F Structural Flowable Grout Fill Material Evaluation And Recommendations

    International Nuclear Information System (INIS)

    Langton, C. A.; Stefanko, D. B.

    2013-01-01

    Cementitious grout will be used to close Tanks 18-F and 19-F. The functions of the grout are to: 1) physically stabilize the final landfill by filling the empty volume in the tanks with a non-compressible material; 2) provide a barrier for inadvertent intrusion into the tank; 3) reduce contaminant mobility by a) limiting the hydraulic conductivity of the closed tank and b) reducing contact between the residual waste and infiltrating water; and 4) providing an alkaline, chemically reducing environment in the closed tank to control speciation and solubility of selected radionuclides. The objective of this work was to identify a single (all-in-one) grout to stabilize and isolate the residual radionuclides in the tank, provide structural stability of the closed tank and serve as an inadvertent intruder barrier. This work was requested by V. A. Chander, High Level Waste (HLW) Tank Engineering, in HLW-TTR-2011-008. The complete task scope is provided in the Task Technical and QA Plan, SRNL-RP-2011-00587 Revision 0. The specific objectives of this task were to: 1) Identify new admixtures and dosages for formulating a zero bleed flowable tank fill material selected by HLW Tank Closure Project personnel based on earlier tank fill studies performed in 2007. The chemical admixtures used for adjusting the flow properties needed to be updated because the original admixture products are no longer available. Also, the sources of cement and fly ash have changed, and Portland cements currently available contain up to 5 wt. % limestone (calcium carbonate). 2) Prepare and evaluate the placement, compressive strength, and thermal properties of the selected formulation with new admixture dosages. 3) Identify opportunities for improving the mix selected by HLW Closure Project personnel and prepare and evaluate two potentially improved zero bleed flowable fill design concepts; one based on the reactor fill grout and the other based on a shrinkage compensating flowable fill mix design. 4

  15. Tanks 18 And 19-F Structural Flowable Grout Fill Material Evaluation And Recommendations

    International Nuclear Information System (INIS)

    Stefanko, D.; Langton, C.

    2011-01-01

    Cementitious grout will be used to close Tanks 18-F and 19-F. The functions of the grout are to: (1) physically stabilize the final landfill by filling the empty volume in the tanks with a non compressible material; (2) provide a barrier for inadvertent intrusion into the tank; (3) reduce contaminant mobility by (a) limiting the hydraulic conductivity of the closed tank and (b) reducing contact between the residual waste and infiltrating water; and (4) providing an alkaline, chemically reducing environment in the closed tank to control speciation and solubility of selected radionuclides. The objective of this work was to identify a single (all-in-one) grout to stabilize and isolate the residual radionuclides in the tank, provide structural stability of the closed tank and serve as an inadvertent intruder barrier. This work was requested by V. A. Chander, High Level Waste (HLW) Tank Engineering, in HLW-TTR-2011-008. The complete task scope is provided in the Task Technical and QA Plan, SRNL-RP-2011-00587 Revision 0. The specific objectives of this task were to: (1) Identify new admixtures and dosages for formulating a zero bleed flowable tank fill material selected by HLW Tank Closure Project personnel based on earlier tank fill studies performed in 2007. The chemical admixtures used for adjusting the flow properties needed to be updated because the original admixture products are no longer available. Also, the sources of cement and fly ash have changed, and Portland cements currently available contain up to 5 wt. % limestone (calcium carbonate). (2) Prepare and evaluate the placement, compressive strength, and thermal properties of the selected formulation with new admixture dosages. (3) Identify opportunities for improving the mix selected by HLW Closure Project personnel and prepare and evaluate two potentially improved zero bleed flowable fill design concepts; one based on the reactor fill grout and the other based on a shrinkage compensating flowable fill mix

  16. Tanks 18 And 19-F Structural Flowable Grout Fill Material Evaluation And Recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Langton, C. A.; Stefanko, D. B.

    2013-04-23

    Cementitious grout will be used to close Tanks 18-F and 19-F. The functions of the grout are to: 1) physically stabilize the final landfill by filling the empty volume in the tanks with a non-compressible material; 2) provide a barrier for inadvertent intrusion into the tank; 3) reduce contaminant mobility by a) limiting the hydraulic conductivity of the closed tank and b) reducing contact between the residual waste and infiltrating water; and 4) providing an alkaline, chemically reducing environment in the closed tank to control speciation and solubility of selected radionuclides. The objective of this work was to identify a single (all-in-one) grout to stabilize and isolate the residual radionuclides in the tank, provide structural stability of the closed tank and serve as an inadvertent intruder barrier. This work was requested by V. A. Chander, High Level Waste (HLW) Tank Engineering, in HLW-TTR-2011-008. The complete task scope is provided in the Task Technical and QA Plan, SRNL-RP-2011-00587 Revision 0. The specific objectives of this task were to: 1) Identify new admixtures and dosages for formulating a zero bleed flowable tank fill material selected by HLW Tank Closure Project personnel based on earlier tank fill studies performed in 2007. The chemical admixtures used for adjusting the flow properties needed to be updated because the original admixture products are no longer available. Also, the sources of cement and fly ash have changed, and Portland cements currently available contain up to 5 wt. % limestone (calcium carbonate). 2) Prepare and evaluate the placement, compressive strength, and thermal properties of the selected formulation with new admixture dosages. 3) Identify opportunities for improving the mix selected by HLW Closure Project personnel and prepare and evaluate two potentially improved zero bleed flowable fill design concepts; one based on the reactor fill grout and the other based on a shrinkage compensating flowable fill mix design. 4

  17. TANKS 18 AND 19-F STRUCTURAL FLOWABLE GROUT FILL MATERIAL EVALUATION AND RECOMMENDATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Stefanko, D.; Langton, C.

    2011-11-01

    Cementitious grout will be used to close Tanks 18-F and 19-F. The functions of the grout are to: (1) physically stabilize the final landfill by filling the empty volume in the tanks with a non compressible material; (2) provide a barrier for inadvertent intrusion into the tank; (3) reduce contaminant mobility by (a) limiting the hydraulic conductivity of the closed tank and (b) reducing contact between the residual waste and infiltrating water; and (4) providing an alkaline, chemically reducing environment in the closed tank to control speciation and solubility of selected radionuclides. The objective of this work was to identify a single (all-in-one) grout to stabilize and isolate the residual radionuclides in the tank, provide structural stability of the closed tank and serve as an inadvertent intruder barrier. This work was requested by V. A. Chander, High Level Waste (HLW) Tank Engineering, in HLW-TTR-2011-008. The complete task scope is provided in the Task Technical and QA Plan, SRNL-RP-2011-00587 Revision 0. The specific objectives of this task were to: (1) Identify new admixtures and dosages for formulating a zero bleed flowable tank fill material selected by HLW Tank Closure Project personnel based on earlier tank fill studies performed in 2007. The chemical admixtures used for adjusting the flow properties needed to be updated because the original admixture products are no longer available. Also, the sources of cement and fly ash have changed, and Portland cements currently available contain up to 5 wt. % limestone (calcium carbonate). (2) Prepare and evaluate the placement, compressive strength, and thermal properties of the selected formulation with new admixture dosages. (3) Identify opportunities for improving the mix selected by HLW Closure Project personnel and prepare and evaluate two potentially improved zero bleed flowable fill design concepts; one based on the reactor fill grout and the other based on a shrinkage compensating flowable fill mix

  18. Broadband giant-refractive-index material based on mesoscopic space-filling curves

    Science.gov (United States)

    Chang, Taeyong; Kim, Jong Uk; Kang, Seung Kyu; Kim, Hyowook; Kim, Do Kyung; Lee, Yong-Hee; Shin, Jonghwa

    2016-08-01

    The refractive index is the fundamental property of all optical materials and dictates Snell's law, propagation speed, wavelength, diffraction, energy density, absorption and emission of light in materials. Experimentally realized broadband refractive indices remain 1,800 resulting from a mesoscopic crystal with a dielectric constant greater than three million. This gigantic enhancement effect originates from the space-filling curve concept from mathematics. The principle is inherently very broad band, the enhancement being nearly constant from zero up to the frequency of interest. This broadband giant-refractive-index medium promises not only enhanced resolution in imaging and raised fundamental absorption limits in solar energy devices, but also compact, power-efficient components for optical communication and increased performance in many other applications.

  19. Three-dimensional evaluation of effectiveness of hand and rotary instrumentation for retreatment of canals filled with different materials.

    Science.gov (United States)

    Hammad, Mohammad; Qualtrough, Alison; Silikas, Nick

    2008-11-01

    The aim of this study was to measure the remaining filling volume of different obturation materials from root-filled extracted teeth by using 2 removal techniques. Eighty single-rooted teeth were collected and decoronated, and the root canal was prepared by using the ProTaper nickel-titanium rotary files. The teeth were randomly allocated into 4 groups, and each group was obturated by using a different material. Group 1 was filled with gutta-percha and TubliSeal sealer, group 2 was filled with EndoRez points and EndoRez sealer, group 3 was filled with RealSeal points and RealSeal sealer, and Group 4 was filled with a gutta-percha point and GuttaFlow sealer. Teeth were scanned with a micro-computed tomography scan, and then root fillings were removed by using ProTaper retreatment files or hand K-files. Teeth were scanned again, and volume measurements were carried out with micro-computed tomography software. Statistical analysis showed significant differences between the 2 removal techniques for gutta-percha and for both techniques between gutta-percha and the other groups. The present study showed that all tested filling materials were not completely removed during retreatment by using hand or rotary files. Gutta-percha was more efficiently removed by using hand K-files.

  20. Synthesis of partial stabilized cement-gypsum as new dental retrograde filling material

    Energy Technology Data Exchange (ETDEWEB)

    Sadhasivam, S. [Institute of Biomedical Engineering, National Taiwan University, Taipei, Taiwan (China); Division of Medical Engineering Research, National Health Research Institute, Zhunan, Miaoli County, Taiwan (China); Chen, Jung-Chih [Institute of Biomedical Engineering, National Taiwan University, Taipei, Taiwan (China); Medical Device Innovation Center, National Cheng Kung University, Tainan,Taiwan (China); Savitha, S. [Institute of Biomedical Engineering, National Taiwan University, Taipei, Taiwan (China); Hsu, Ming-Xiang; Hsu, Chung-King [Institute of Materials Science and Engineering, National Taipei University of Technology, Taipei, Taiwan (China); Lin, Chun-Pin [School of Dentistry and Graduate Institute of Clinical Dentistry, College of Medicine, National Taiwan University and National Taiwan University Hospital, Taipei, Taiwan (China); Lin, Feng-Huei, E-mail: double@ntu.edu.tw [Institute of Biomedical Engineering, National Taiwan University, Taipei, Taiwan (China); Division of Medical Engineering Research, National Health Research Institute, Zhunan, Miaoli County, Taiwan (China)

    2012-10-01

    The study describes the sol-gel synthesis of a new dental retrograde filling material partial stabilized cement (PSC)-gypsum by adding different weight percentage of gypsum (25% PSC + 75% gypsum, 50% PSC + 50% gypsum and 75% PSC + 25% gypsum) to the PSC. The crystalline phase and hydration products of PSC-gypsum were characterized by X-ray diffraction (XRD) and scanning electron microscopy (SEM) analysis. The handling properties such as setting time, viscosity, tensile strength, porosity and pH, were also studied. The XRD and microstructure analysis demonstrated the formation of hydroxyapatite and removal of calcium dihydrate during its immersion in simulated body fluid (SBF) on day 10 for 75% PSC + 25% gypsum. The developed PSC-gypsum not only improved the setting time but also greatly reduced the viscosity, which is very essential for endodontic surgery. The cytotoxic and cell proliferation studies indicated that the synthesized material is highly biocompatible. The increased alkaline pH of the PSC-gypsum also had a remarkable antibacterial activity. - Highlights: Black-Right-Pointing-Pointer A new dental retrograde filling material PSC-gypsum was developed. Black-Right-Pointing-Pointer PSC-gypsum cement has shown excellent initial and final setting time as 15-35 min. Black-Right-Pointing-Pointer It not only improved the setting time but also retain the viscosity, 2 Pa{center_dot}s. Black-Right-Pointing-Pointer High alkaline pH of the cement had a remarkable antibacterial activity. Black-Right-Pointing-Pointer Cytotoxicity studies revealed that the synthesized material is highly biocompatible.

  1. Radiopacity evaluation of new root canal filling materials by digitalization of images.

    Science.gov (United States)

    Tanomaru-Filho, Mário; Jorge, Erica Gouveia; Guerreiro Tanomaru, Juliane Maria; Gonçalves, Marcelo

    2007-03-01

    The aim of this study was to evaluate the radiopacity of five root canal filling materials (AH Plus, Intrafill, Roeko Seal, Epiphany, and EndoRez). Following the International Organization of Standardization 6876/2001, five circular specimens (10 x 1 mm) were made from each material. After the material set, radiographs were made using occlusal film and a graduated aluminum step-wedge varying in thickness from 2 to 16 mm. The dental X-ray unit (GE1000) was set at 50 Kvp, 10 mA, 18 pulses/second, and distance of 33.5 cm. The radiographs were digitized, and the radiopacity was compared with the aluminum step-wedge, using WIXWIN-2000 software (Gendex). Data (mm Al) were analyzed using ANOVA and Tukey tests. AH Plus and Epiphany were the most radiopaque materials (9.8 and 8.8 mm Al, respectively), followed by EndoRez (7.2 mm Al). Roeko Seal and Intrafill presented the lowest radiopacity values (5.7 and 6.1 mm Al, respectively). Although the materials evaluated demonstrated different radiopacities, all had values above the minimum recommended by the International Organization of Standardization.

  2. Nd:YAG laser in endodontics: filling-material edge bordering on a root channel laser cavity

    Science.gov (United States)

    Belikov, Andrei V.; Sinelnik, Yuri A.; Moroz, Boris T.; Pavlovskaya, Irina V.

    1997-12-01

    For the very first time it is represented a study of filling material edge bordering upon root channel cavity modified with a laser. As a filling material it is used a glass ionomer cement. It is demonstrated that Nd:YAG laser radiation effects on increase of grade of edge bordering on the average of 20 - 30% at temperature rise of no more than 2 - 3 degrees in periodontium area in a period of operation.

  3. Study on filling materials suitable for seawater piping trench closure work at Fukushima Daiichi Nuclear Power Plant

    International Nuclear Information System (INIS)

    Yanai, Shuji; Hibi, Yasuki; Nishikori, Kazumasa; Sato, Keita

    2016-01-01

    Highly contaminated water leaking from the reactor buildings and turbine buildings damaged by the 2011 Great East Japan Earthquake has accumulated in the seawater piping trenches of Fukushima Daiichi Nuclear Power Station Units 2, 3, and 4. In November 2014, work commenced to replace and remove this contaminated water by filling the trenches with filling materials, and this work was completed in December 2015. This paper summarizes the contents of this study on various filling materials, including special fillers with long-distance underwater flowability applied to the horizontal tunnel parts of the trenches. (author)

  4. Midfacial analysis and planning for midface augmentation with injectable filling materials: an anatomical approach.

    Science.gov (United States)

    Taheri, A; Mansoori, P

    2012-06-01

      Midfacial augmentation improves the appearance of patients with flat or ptotic cheek.   To develop a simple method of preoperative delineating the location of the ideal malar prominence and determining the best area to augment with injectable filling materials.   We used detailed analysis of the facial features of some Caucasian men and women as the basis for this study.   We described a technique to locate the ideal malar prominence and proposed a classification of midfacial contour defects.   This method greatly simplifies the surgeon's task of determining the area to be augmented. © 2011 The Authors. Journal of the European Academy of Dermatology and Venereology © 2011 European Academy of Dermatology and Venereology.

  5. Evaluation of a new nano-filled restorative material for bonding orthodontic brackets.

    Science.gov (United States)

    Bishara, Samir E; Ajlouni, Raed; Soliman, Manal M; Oonsombat, Charuphan; Laffoon, John F; Warren, John

    2007-01-01

    To compare the shear bond strength of a nano-hybrid restorative material, Grandio (Voco, Cuxhaven, Germany), to that of a traditional adhesive material (Transbond XT; 3M Unitek, Monrovia, CA, USA) when bonding orthodontic brackets. Forty teeth were randomly divided into 2 groups: 20 teeth were bonded with the Transbond adhesive system and the other 20 teeth with the Grandio restorative system, following manufacturer's instructions. Student t test was used to compare the shear bond strength of the 2 systems. Significance was predetermined at P 5 .05. The t test comparisons (t = 0.55) of the shear bond strength between the 2 adhesives indicated the absence of a significant (P = .585) difference. The mean shear bond strength for Grandio was 4.1 +/- 2.6 MPa and that for Transbond XT was 4.6 +/- 3.2 MPa. During debonding, 3 of 20 brackets (15%) bonded with Grandio failed without registering any force on the Zwick recording. None of the brackets bonded with Transbond XT had a similar failure mode. The newly introduced nano-filled composite materials can potentially be used to bond orthodontic brackets to teeth if its consistency can be more flowable to readily adhere to the bracket base.

  6. Potential of fish scales as a filling material in surface coating of cellulosic paper.

    Science.gov (United States)

    Ural, Elif; Kandirmaz, Emine A

    2018-01-01

    Paper is one of the important inputs for the printing industry, and the most important leading parameter in the printing process is its brightness. Brightness can be brought to paper using coatings and sizing. Desired surface properties and, most importantly, surface roughness can be achieved by changing the contents of the coating and sizing of the materials it contains. The use of biomaterials is becoming more important in the paper industry, as they represent substances with a lower carbon footprint. Fish scales are already used as a filling material, cosmetic material and fish food, as well as for determining the age of fish. Fish scales were brought to different sizes by a milling process. Paper formulations including different amounts of fish scales were prepared with fish scales, and coatings on raw paper were subjected to test printings in IGT-C1, with formulations and physical characteristics of coatings such as brightness, lightfastness, strength, adhesion etc. being determined. Regarding the value of yellowness, mixtures of 2.5%-10% can be used. The maximum value of brightness was obtained from a mixture of 10%. Aging visibly changed the colors. The coatings obtained were brighter than the initial coating compositions. The top quality formulation was the coating with 5% medium-sized fish scale particles.

  7. Rock fill in a KBS-3 repository. Rock material for filling of shafts and ramps in a KBS-3V repository in the closure phase

    International Nuclear Information System (INIS)

    Pusch, Roland

    2008-09-01

    The content of large blocks in blasted rock makes it impossible to fill and compact the material effectively unless those larger than about 500 mm are removed. Tunnel Boring Machine (TBM) muck gives flat chips, that are usually not longer than a couple of decimeters, and serves better as backfill. The granulometrical composition of both types can be more suitable for effective compaction by crushing, which is hence a preferable process. Use of unsorted, unprocessed blasted rock can only be accepted if the density and physical properties, like self-compaction, are not important. Crushing of blasted rock and TBM muck for backfilling can be made in one or two steps depending on the required gradation. Placement of rock fill is best made by use of tractors with blades that push the material forwards over already placed and compacted material. The dry density of well graded rock fill effectively compacted by very heavy vibratory rollers can be as high as 2,400 kg/m3. For road compaction by ordinary vibratory rollers common dry density values are in the interval 2,050 to 2,200 kg m 3 . Blasted rock dumped and moved on site by tractors can get an average dry density of 1,600-1,800 kg/m3 without compaction. Crushed, blasted rock and TBM muck placed by tractors in horizontal layers and compacted by 5-10 t vibrating rollers in the lower part of the rooms, and moved by tractors to form inclined layers compacted by vibrating plates in the upper part, would get a dry density of 1,900-2,000 kg/m 3 . Flushing water over the rock fill in conjunction with the compaction work gives more effective densification than dry compaction. Based on recorded settlement of Norwegian rock fill dams constructed with water flushing it is estimated that the self-compaction of a 5 m high backfill of crushed rock or TBM muck causes a settlement of the top of the backfill of about 8 mm while a 200 m high shaft fill would undergo compression by more than half a meter. Repeated, strong earthquakes may

  8. Rock fill in a KBS-3 repository. Rock material for filling of shafts and ramps in a KBS-3V repository in the closure phase

    Energy Technology Data Exchange (ETDEWEB)

    Pusch, Roland (Geodevelopment International AB/SWECO AB, Lund (Sweden))

    2008-09-15

    The content of large blocks in blasted rock makes it impossible to fill and compact the material effectively unless those larger than about 500 mm are removed. Tunnel Boring Machine (TBM) muck gives flat chips, that are usually not longer than a couple of decimeters, and serves better as backfill. The granulometrical composition of both types can be more suitable for effective compaction by crushing, which is hence a preferable process. Use of unsorted, unprocessed blasted rock can only be accepted if the density and physical properties, like self-compaction, are not important. Crushing of blasted rock and TBM muck for backfilling can be made in one or two steps depending on the required gradation. Placement of rock fill is best made by use of tractors with blades that push the material forwards over already placed and compacted material. The dry density of well graded rock fill effectively compacted by very heavy vibratory rollers can be as high as 2,400 kg/m3. For road compaction by ordinary vibratory rollers common dry density values are in the interval 2,050 to 2,200 kg m3. Blasted rock dumped and moved on site by tractors can get an average dry density of 1,600-1,800 kg/m3 without compaction. Crushed, blasted rock and TBM muck placed by tractors in horizontal layers and compacted by 5-10 t vibrating rollers in the lower part of the rooms, and moved by tractors to form inclined layers compacted by vibrating plates in the upper part, would get a dry density of 1,900-2,000 kg/m3. Flushing water over the rock fill in conjunction with the compaction work gives more effective densification than dry compaction. Based on recorded settlement of Norwegian rock fill dams constructed with water flushing it is estimated that the self-compaction of a 5 m high backfill of crushed rock or TBM muck causes a settlement of the top of the backfill of about 8 mm while a 200 m high shaft fill would undergo compression by more than half a meter. Repeated, strong earthquakes may

  9. 33 CFR 336.1 - Discharges of dredged or fill material into waters of the U.S.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Discharges of dredged or fill material into waters of the U.S. 336.1 Section 336.1 Navigation and Navigable Waters CORPS OF ENGINEERS... ENGINEERS DREDGING PROJECTS INVOLVING THE DISCHARGE OF DREDGED MATERIAL INTO WATERS OF THE U.S. AND OCEAN...

  10. 3D Surface Profile and Color Stability of Tooth Colored Filling Materials after Bleaching

    Directory of Open Access Journals (Sweden)

    Bryant Anthony Irawan

    2015-01-01

    Full Text Available This study aims to evaluate the effects of vital tooth bleaching with carbamide peroxide home bleaching and in-office bleaching on the color stability and 3D surface profile of dental restorative filling materials. Thirty discs (n=30 measure 6 mm in diameter and 2 mm thick for each of three restorative materials. These are nanofilled composite Filtek Z350 XT, the submicron composite Estelite Σ Quick, and nanofilled glass ionomer Ketac N100 nanoionomer and were fabricated in shade A2. Each group was further divided into three subgroups (n=10: subgroup A (Opalescence PF, subgroup B (Opalescence Boost in-office bleaching, and subgroup C (distilled water serving as control. Samples were bleached according to the manufacturer’s instructions for a period of two weeks. The Commission Internationale de L’Eclairage (CIE L*, a*, b* system was chosen for image processing, while 3D surface profile was tested with atomic force microscopy (AFM. Statistical analyses were performed with the Mann-Whitney tests and Krusal-Wallis with a P value of ≤0.05. The three restorative materials showed significant color changes (ΔE; P≤0.05. In diminishing order, the mean color changes recorded were Estelite Σ (3.82 ± 1.6 > Ketac Nano (2.97 ± 1.2 > Filtek Z350 XT (2.25 ± 1.0. However, none of the tested materials showed statistically significant changes in surface roughness; P>0.05.

  11. The apical leakage of mineral trioxide aggregate as the retrograde filling material with various mixing agents

    Directory of Open Access Journals (Sweden)

    Ema Mulyawati

    2010-06-01

    Full Text Available Background: Mineral trioxide aggregate (MTA is relatively considered as a new material in endodontic. It even has been used as retrograde filling material due to its biocompatibility, antibacterial effect, sealing ability and anti-moist effect. Some materials have been used as mixing agent to achieve an appropiate setting of MTA. Purpose: The aim of this study is to investigate the effect of the mixing agents of MTA towards the apical leakage when they are used together as retrograde filling materials. Method: The samples of this research consist of 30 human extracted upper central incisors. First, the crown of each tooth is sectioned. The root canals are prepared by using the conventional technique and then are obturated with gutta percha. After cutting the root apex, 2 mm from apical, class 1 cavities are prepared by using fissure bur with the depth of 3 mm. The samples then are divided into 3 groups with 10 teeth for each. Group I uses aquabidest as mixing agent of MTA (MTA-aquabidest, group II uses saline (MTA-saline, while group III uses 0.12% chlorhexidine (MTA-chlorhexidine. The apex of each group then is filled with the mixing MTA determined already. Afterwards, clearing method is used to evaluate the apical leakage. The apical leakage actually is determined by measuring the depth of methylene blue penetration with stereomicroscope. The statictical analyses of the linear dye penetration then are performed with analysis of varians ANOVA. Result: The dye penetration for both MTA-aquadest and MTA-saline groups indicates the lowest penetration, and there is even a significant difference compared with MTA-0.12% chlorhexidine group (p<0.005. Conclusion: It can be concluded that aquabidest and saline as mixing agents of MTA produce less apical leakage compared with 0.12% chlorhexidine.Latar belakang: Mineral trioxide aggregate (MTA merupakan bahan yang relatif baru dalam bidang endodontik. Bahan tersebut diindikasikan sebagai bahan pengisi

  12. Friction Properties of Laminated Composite Materials of Alpha-Tricalcium Phosphate–Filled Poly (Vinyl Alcohol) Hydrogels

    OpenAIRE

    Yamamoto, Kanae; Iwai, Tomoaki; Shoukaku, Yutaka

    2015-01-01

    The aim of this study was to examine the mechanical characteristics of a polyvinyl alcohol hydrogel (PVA-H) as a candidate material for artificial joint cartilage. In the study, PVA-H was filled with α-tricalcium phosphate (α-TCP) in order to improve its mechanical properties. In addition, laminated composite materials with 3 layers were prepared by laminating α-TCP–filled PVA-H and unfilled PVA-H. The samples were prepared with different numbers of repeated freeze–thaw cycles and several con...

  13. Designing dual phase sensing materials from polyaniline filled styrene–isoprene–styrene composites

    International Nuclear Information System (INIS)

    Sadasivuni, Kishor Kumar; Ponnamma, Deepalekshmi; Kasak, Peter; Krupa, Igor; Ali S A Al-Maadeed, Mariam

    2014-01-01

    The demand for developing oil detectors is ever increasing since the cleanup and recovery from oil spill usually take long time. Here we propose oil sensors made of polyaniline (PANI) filled poly(styrene–isoprene–styrene) (SIS) block copolymer composite films with good uniformity and dispersion. The changes in resistivity of the samples in presence of both oil and water media reveal the good sensing ability of SIS–PANI films towards oil in water (dual phase). The morphology and chemical composition of the developed products are characterized by scanning electron microscopy and Fourier transformation infrared spectroscopy. Swelling studies are performed to correlate the sensing response to the structural variations and based on it a mechanism is derived for the dual phase sensing. Contact angle measurements confirm the behavior further. The thermal properties and crystallinity of the composites are also addressed by the thermogravimetric and differential scanning calorimetric studies. The developed oil sensor material is able to withstand extreme temperature condition as well. - Highlights: • We model a dual phase sensor capable of detecting oil in water. • A mechanism is proposed to correlate sensing with diffusion. • In situ polymerization helps in the uniform distribution of filler. • Polymer composite sensor could be used as stickers on oil pipelines

  14. Cytotoxic effects of cyanoacrylates used as retrograde filling materials: an in vitro analysis

    Directory of Open Access Journals (Sweden)

    Azevedo Cledson Lima de

    2003-01-01

    Full Text Available Cyanoacrylate has been used in medicine and dentistry for many years. It has been used as a postextraction dressing and retrograde filling material in endodontic surgery. The aim of this study was to evaluate the cytotoxic effects of Histoacryl and other two homologue ethyl cyanoacrylates, Super Bonder and Ultrabond, on cultured fibroblasts, using the Trypan blue dye exclusion assay. The cyanoacrylates were applied to round glass coverslips, which were placed in contact with NIH 3T3 cells. After 0, 6, 12 and 24 h (short-term assay; viability and 1, 3, 5 and 7 days (long-term assay; survival, the cells were examined under phase light microscopy and counted. The data were compared by the Kruskal-Wallis test. In the short-term experiments, only the cultures of the Ultrabond group (GIV presented significant smaller percentages of cell viability than the cultures of the other groups (GI: control; GII: Super Bonder; GIII: Histoacryl. Although the cultures of the Super Bonder group (GII presented smaller percentages of cell viability than cultures of the other groups (GI, GIII, GIV at the long-term assay, this group was the only experimental group presenting a continuous and progressive cell growth. Our results have shown an in vitro biocompatibility of Histoacryl and ethyl cyanoacrylate homologues. These cyanoacrylates could therefore be of importance for endodontic purposes.

  15. Designing dual phase sensing materials from polyaniline filled styrene–isoprene–styrene composites

    Energy Technology Data Exchange (ETDEWEB)

    Sadasivuni, Kishor Kumar, E-mail: kishor_kumars@yahoo.com [Centre for Advanced Materials, Qatar University, Doha (Qatar); Ponnamma, Deepalekshmi [School of Chemical Sciences, Mahatma Gandhi University, Kottayam 686560, Kerala (India); Kasak, Peter; Krupa, Igor; Ali S A Al-Maadeed, Mariam [Centre for Advanced Materials, Qatar University, Doha (Qatar)

    2014-10-15

    The demand for developing oil detectors is ever increasing since the cleanup and recovery from oil spill usually take long time. Here we propose oil sensors made of polyaniline (PANI) filled poly(styrene–isoprene–styrene) (SIS) block copolymer composite films with good uniformity and dispersion. The changes in resistivity of the samples in presence of both oil and water media reveal the good sensing ability of SIS–PANI films towards oil in water (dual phase). The morphology and chemical composition of the developed products are characterized by scanning electron microscopy and Fourier transformation infrared spectroscopy. Swelling studies are performed to correlate the sensing response to the structural variations and based on it a mechanism is derived for the dual phase sensing. Contact angle measurements confirm the behavior further. The thermal properties and crystallinity of the composites are also addressed by the thermogravimetric and differential scanning calorimetric studies. The developed oil sensor material is able to withstand extreme temperature condition as well. - Highlights: • We model a dual phase sensor capable of detecting oil in water. • A mechanism is proposed to correlate sensing with diffusion. • In situ polymerization helps in the uniform distribution of filler. • Polymer composite sensor could be used as stickers on oil pipelines.

  16. The effects of irradiance and exposure time on the surface roughness of bulk-fill composite resin restorative materials

    Science.gov (United States)

    Alkhudhairy, Fahad I.

    2018-01-01

    Objectives: To evaluate the surface roughness of 4 different bulk-fill resin-based composites cured using different irradiance levels. Methods: This in vitro study was performed in February 2017 to August 2017 at the College of Dentistry, King Saud University. Twenty-four specimens were prepared from each of the bulk-fill materials [Tetric N-Ceram (TNC), SonicFill (SF), Smart Dentin Replacement (SDR), and Filtek Bulk-Fill (FB)] using a brass metal mold, resulting in a total of 96 specimens, cured using a Bluephase N light curing unit. Half of the total number of specimens (N=48) were cured using high-power irradiance (1200 mW/cm2) for 20 seconds, while the remaining half (N=48) were cured using low power irradiance (650 mW/cm2) for 40 seconds. After 24 hours, baseline surface roughness of each specimen was analyzed using a profilometer, then polished using Sof-lex abrasive disks, and the surface roughness of all groups was assessed. Results: Post-polished SonicFill cured at high irradiance had the highest mean surface roughness (0.23±0.03), whereas pre-polished Smart Dentin Replacement (0.11±0.01) and SonicFill (0.11±0.02) cured at low irradiance had the lowest mean surface roughness. Conclusion: High curing irradiance (1,200 mW/cm2) had no positive influence on the surface roughness of Filtek Bulk Fill and Tetric N-Ceram bulk-fill RBCs compared with lower curing irradiance (650 mW/cm2). However, the difference of curing irradiance significantly affected the surface roughness in SDR and sonic fill RBCs. PMID:29436570

  17. Depleted uranium oxides as spent-nuclear-fuel waste-package fill materials

    International Nuclear Information System (INIS)

    Forsberg, C.W.

    1997-01-01

    Depleted uranium dioxide fill inside the waste package creates the potential for significant improvements in package performance based on uranium geochemistry, reduces the potential for criticality in a repository, and consumes DU inventory. As a new concept, significant uncertainties exist: fill properties, impacts on package design, post- closure performance

  18. Influence of dental filling material type on the concentration of interleukin 9 in the samples of gingival crevicular fluid

    Directory of Open Access Journals (Sweden)

    Stefanović Vladimir

    2016-01-01

    Full Text Available Background/Aim. Several cytokines and lymphokines (IL1β, ENA78, IL6, TNFα, IL8 and S100A8 are expressed during dental pulp inflammation. Analysis of gingival crevicu-lar fluid (GCF offers a non-invasive means of studying gen-eral host response in oral cavity. Although GCF levels of various mediators could reflect the state of inflammation both in dental pulp and gingiva adjacent to a tooth, GCF samples of those without significant gingivitis could be inter-preted as reflection of pulpal process. The aim of this study was to investigate IL9 GCF values in patients with dental car-ies and to assess possible influence of various dental fillings materials on local IL9 production. Methods. The study group included 90 patients, aged 18–70, with inclusion and exclusion criteria in the prospective clinical study. Of the 6 types of material used for the restoration of prepared cavities, 3 were intended for temporary and 3 for definitive restora-tion. According to dental fillings weight, all the participants were divided into 3 groups: those with fillings lighter than 0.50 g, those with 0.50–1.00 g, and those with fillings heavier than 1.00 g. Samples were taken from gingival sulcus using the filter paper technique. Clinical parameters were deter-mined by bleeding index, plaque index (Silness-Lou, 0–3, gingival index (0–3, and gingival sulcus depth. Cytokine con-centrations were assessed using commercially available cy-tomix. Results. According to the weight of dental fillings, there was a clear decreament trend of IL9 values meaning that dental defects greater than 1.00 g of dental filling were associated with lower GCF IL9 concentration. The IL9 val-ues correlated with the degree of gingival index and depth of gingival sulcus, being higher with more advanced gingivitis and more pronounced anatomical changes in the tooth edge. Different filling materials exerted various local IL9 responses. Zink polycarbonate cement and amalgam fillings induced

  19. About Dental Amalgam Fillings

    Science.gov (United States)

    ... and Medical Procedures Dental Devices Dental Amalgam About Dental Amalgam Fillings Share Tweet Linkedin Pin it More ... should I have my fillings removed? What is dental amalgam? Dental amalgam is a dental filling material ...

  20. Quantitative assessment of image artifacts from root filling materials on CBCT scans made using several exposure parameters

    Energy Technology Data Exchange (ETDEWEB)

    Rabelo, Katharina Alves; Cavalcanti, Yuri Wanderley; De Oliveira Pinto, Martina Gerlane; De Melo, Daniela Pita [Dept. of Oral Diagnosis, State University of Paraiba, Campina Grande (Brazil); Melo, Saulo Leonardo Sousa [Dept. of Oral Pathology, Radiology and Medicine, University of Iowa, Iowa City (United States); Campos, Paulo Sergio Flores; De Andrade Freitas Oliveira, Luciana Soares [Federal University of Bahia, Salvador (Brazil)

    2017-09-15

    To quantify artifacts from different root filling materials in cone-beam computed tomography (CBCT) images acquired using different exposure parameters. Fifteen single-rooted teeth were scanned using 8 different exposure protocols with 3 different filling materials and once without filling material as a control group. Artifact quantification was performed by a trained observer who made measurements in the central axial slice of all acquired images in a fixed region of interest using ImageJ. Hyperdense artifacts, hypodense artifacts, and the remaining tooth area were identified, and the percentages of hyperdense and hypodense artifacts, remaining tooth area, and tooth area affected by the artifacts were calculated. Artifacts were analyzed qualitatively by 2 observers using the following scores: absence (0), moderate presence (1), and high presence (2) for hypodense halos, hypodense lines, and hyperdense lines. Two-way ANOVA and the post-hoc Tukey test were used for quantitative and qualitative artifact analysis. The Dunnet test was also used for qualitative analysis. The significance level was set at P<.05. There were no significant interactions among the exposure parameters in the quantitative or qualitative analysis. Significant differences were observed among the studied filling materials in all quantitative analyses. In the qualitative analyses, all materials differed from the control group in terms of hypodense and hyperdense lines (P<.05). Fiberglass posts did not differ statistically from the control group in terms of hypodense halos (P>.05). Different exposure parameters did not affect the objective or subjective observations of artifacts in CBCT images; however, the filling materials used in endodontic restorations did affect both types of assessments.

  1. Experimental investigation of different fill materials in arch bridges with particular focus on Pearl-Chain Bridges

    DEFF Research Database (Denmark)

    Lund, Mia Schou Møller; Hansen, Kurt Kielsgaard; Hertz, Kristian Dahl

    2016-01-01

    Pearl-Chain Bridge technology is a recently developed prefabricated arch solution for road and railway bridges allowing faster, more environmentally friendly, and cheaper bridge construction. This study compared the strength and durability properties of three different types of fill material...

  2. Quantitative assessment of image artifacts from root filling materials on CBCT scans made using several exposure parameters

    International Nuclear Information System (INIS)

    Rabelo, Katharina Alves; Cavalcanti, Yuri Wanderley; De Oliveira Pinto, Martina Gerlane; De Melo, Daniela Pita; Melo, Saulo Leonardo Sousa; Campos, Paulo Sergio Flores; De Andrade Freitas Oliveira, Luciana Soares

    2017-01-01

    To quantify artifacts from different root filling materials in cone-beam computed tomography (CBCT) images acquired using different exposure parameters. Fifteen single-rooted teeth were scanned using 8 different exposure protocols with 3 different filling materials and once without filling material as a control group. Artifact quantification was performed by a trained observer who made measurements in the central axial slice of all acquired images in a fixed region of interest using ImageJ. Hyperdense artifacts, hypodense artifacts, and the remaining tooth area were identified, and the percentages of hyperdense and hypodense artifacts, remaining tooth area, and tooth area affected by the artifacts were calculated. Artifacts were analyzed qualitatively by 2 observers using the following scores: absence (0), moderate presence (1), and high presence (2) for hypodense halos, hypodense lines, and hyperdense lines. Two-way ANOVA and the post-hoc Tukey test were used for quantitative and qualitative artifact analysis. The Dunnet test was also used for qualitative analysis. The significance level was set at P .05). Different exposure parameters did not affect the objective or subjective observations of artifacts in CBCT images; however, the filling materials used in endodontic restorations did affect both types of assessments

  3. Feasibility of soil-EFB mixtures as a filled barrier material for waste disposal site

    International Nuclear Information System (INIS)

    Kamarudin Samuding; Ismail Abustan; Mohd Tadza Abdul Rahman; Mohamed Hasnain Isa

    2010-01-01

    This paper present the results of laboratory experiment that is involved the characterization and removal efficiency test of soil-EFB (Empty Fruit Bunch) of oil palm mixture. In this study, soil samples were mixed with EFB at 10 % (EFB10), 30 % (EFB30), and 50 % (EFB50). The characterization included the physical and chemical properties of the soil-EFB mixture such as compaction behaviour, cation exchange capacity, permeability and its surface physical morphology. Batch Equilibrium Test was performed in order to determine the adsorption capability of the soil-EFB mixture with the heavy metals solution. Five solutions with different concentrations (2.5 mg/l, 5.0 mg/l, 7.5 mg/l, 10.0 mg/l and 12.5 mg/l) were used in this experiment. Base on the compaction test, the value of optimum water content was influence by the EFB introduced into the soil. This is due to the presence of hydroxyl group, which was probably attributed to absorb water. The permeability of the soil-EFB mixtures ranges from 2.4 x 10 -7 to 6.5 x 10 -7 cm/s meanwhile the Cation Exchange Capacity (CEC) result ranges from 11.6 to 31.9 meq/ 100 g. The study has revealed that different percentages of soil-EFB mixture possess different capabilities to remove heavy metals. From the removal efficiency test, it is shown that the removal percentages of heavy metals for soil-EFB mixtures were relatively high as compared to soil alone. Based on the characterization and removal data, the soil-EFB mixture has a good potential to be used as filled barrier material. (author)

  4. Filling material for a buried cavity in a collapse area using light-weighted foam and active feldspar

    Science.gov (United States)

    Cho, Jin Woo; Lee, Ju-hyoung; Kim, Sung-Wook; Choi, Eun-Kyeong

    2017-04-01

    Concrete which is generally used as filling material for a buried cavity has very high strength but significantly high self-load is considered its disadvantage. If it is used as filling material, the second collapse due to additional load, causing irreversible damage. If light-weighted foam and active feldspar are used to solve this problem, the second collapse can be prevented by reducing of self-load of filling material. In this study, the specimen was produced by mixing light-weighted foam, active feldspar and cement, and changes in the density, unconfined compressive strength and hydraulic conductivity were analyzed. Using the light-weighted foam could enable the adjustment of density of specimen between 0.5 g/cm3 and 1.7 g/cm3, and if the mixing ratio of the light-weighted foam increases, the specimen has more pores and smaller range of cross-sectional area. It is confirmed that it has direct correlation with the density, and if the specimen has more pores, the density of the specimen is lowered. The density of the specimen influences the unconfined compressive strength and the hydraulic conductivity, and it was also confirmed that the unconfined compressive strength could be adjusted between 0.6 MPa and 8 MPa and the hydraulic conductivity could be adjusted between 10-9cm/sec and 10-3cm/sec. These results indicated that we can adjust unconfined compressive strength and hydraulic conductivity of filling materials by changing the mixing amount of lightweight-weighted foam according to the requirements of the field condition. Keywords: filling material, buried cavity, light-weighted foam, feldspar Acknowledgement This research was supported by a Grant from a Strategic Research Project (Horizontal Drilling and Stabilization Technologies for Urban Search and Rescue (US&R) Operation) funded by the Korea Institute of Civil Engineering and Building Technology.

  5. Elaboration of protocol for characterization of clay as a filling material and coverage for surface repository

    International Nuclear Information System (INIS)

    Santos, Daisy Mary Marchezini dos

    2017-01-01

    The nuclear energy in its various applications generates wastes that must be properly treated. The Radioactive Waste Management covers operations since generation of the waste until to its storage in repository ensuring the protection of man and of environment of the possible negative impacts. The radioactive waste are segregated, treated, conditioned in suitable packaging and posteriorly are stored or disposal in repository. The “RBMN Project” is a priority project of CNEN to implementation the repository for the deposition of low and intermediate level radioactive waste generated by nuclear energy activities in Brazil, proposing a definitive solution for its storage. Engineered and natural barriers as the filling layer and coverage layer will compose the disposal system of a near surface repository, concept proposed by the “RBMN Project”. The use these barriers views to avoid or restrict the release of radionuclides present in waste for the humans beings and environment. The waterproofing barriers are composed of clays. Certainly, for the national repository, will be used those clays existing in the place where it will be implanted it. So some fundamentals tests will have to be carried for to verify the suitability of these clays as barriers. These tests were determined and realized with a reference clay, a brazilian bentonite constituted of 67.2% montmorillonite. The results were compared with national and international literature of materials with similar mineralogical features. The values found with 95% reliance were 9.73±0,35 μm for granulometric size. For the moisture content were 13,3±0,6% and for capacity of cationic exchange were , 816±9 mmol.kg"-"1. For the hydraulic conductivity, without the use of internal pressure, it was obtained maximum value of 59.0% saturated. In addition, during the observed period, there was no percolation in the test specimen submitted to internal pressure of 200 kPa. This result leads to the conclusion that the

  6. Proportioning equipment for vibration filling and compacting of grain materials in pipe containers, especially of fuel elements

    International Nuclear Information System (INIS)

    Pinkas, V.; Filip, Z.; Beranek, J.

    1981-01-01

    The equipment consists of a base plate to which are attached the fastening collar fo the pipe container and the guide column with the height-adjustable support. The filling pipe is fixed to the support. The proportioning equipment prevents particles of grain material from segregation, thus allowing to achieve homogeneity of the material in the whole volume to be compacted. It also allows determining the height of the column of material in the pipe container without destructive effects on the stacked material. The equipment is designed for the manufacture of shortened fuel elements. (J.B.)

  7. Effect of the insulation materials filling on the thermal performance of sintered hollow bricks under the air-conditioning intermittent operation

    Directory of Open Access Journals (Sweden)

    Chaoping Hou

    2018-06-01

    Full Text Available Wall insulation performance is an important factor affecting building energy consumption and indoor comfortable level. This study proposes that the insulation materials are filled into the cavities of the sintered hollow brick to replace the single insulation layer. The physical models of typical walls were built by the hollow bricks filled with expanding polystyrene board (EPS in cavities and wall thermal performance is numerically analyzed by the Finite Volume Method under air-conditioning intermittent operation, which conforms to the actual operation rules of air-conditioning. Results show that filling EPS in cavities is beneficial to improve the thermal performance of the bricks, and the larger the EPS filling ratio, the higher the thermal performance improvement. The EPS filling ratio increase has the higher sensitivity on inner surface heat flow under the low EPS filling ratio, and filling EPS in the external cavities is optimum with the decrement rate 5.92% higher than filling EPS in internal cavities for the EPS filling ratio of 20%, while filling EPS in internal and external cavities simultaneously is optimum with decrement rate 2.45%–6.87% higher than that with filling EPS in the internal cavities for the EPS filling ratio of 40%–80%. Keywords: Insulation filling ratio, Insulation filling location, Thermal performance, Sintered hollow bricks

  8. Sealing ability of a new polydimethylsiloxane-based root canal filling material

    NARCIS (Netherlands)

    Özok, A.R.; van der Sluis, L.W.M.; Wu, M.K.; Wesselink, P.R.

    2008-01-01

    We tested the null hypothesis that there is no difference in the sealing ability of GuttaFlow, RoekoSeal, and AH26 in root canals. Sixty extracted mandibular premolars were filled with AH26 (lateral compaction), RoekoSeal, or GuttaFlow (modified single-cone). The sealing ability of the root canal

  9. Sealing ability of a new polydimethylsiloxane-based root canal filling material

    NARCIS (Netherlands)

    Ozok, Ahmet R.; van der Sluis, Lucas W. M.; Wu, Min-Kai; Wesselink, Paul R.

    We tested the null hypothesis that there is no difference in the sealing ability of GuttaFlow, RoekoSeal, and AH26 in root canals. Sixty extracted mandibular premolars were filled with AH26 (lateral compaction), RoekoSeal, or GuttaFlow (modified single-cone). The sealing ability of the root canal

  10. Distribution of anthropogenic fill material within the Y-12 plant area, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Sutton, G.E. Jr.; Field, S.M.

    1995-10-01

    Widespread groundwater contamination in the vicinity of the Oak Ridge Y-12 Plant has been documented through a variety of monitoring efforts since the late 1970s. Various contaminants, most notably volatile organic compounds (VOCs), have migrated through the subsurface and formed extensive contaminant plumes within the Knox Aquifer/Maynardville Limestone, the primary exit pathway for groundwater transport within the Bear Creek Valley. In 1991, an integrated, comprehensive effort (Upper East Fork Poplar Creek [UEFPC] Phase I monitoring network) was initiated in order to (1) identify contaminant source areas within the industrialized portions of the plant and (2) define contamination migration pathways existing between the source areas and the Knox Aquifer/Maynardville Limestone. Data obtained during previous studies have indicated that extensive zones of fill and buried utility trenches may serve as preferred migration pathways. In addition, portions of UEFPC were rerouted, with several of its tributaries being filled during the initial construction of the plant. These filled surface drainage features are also believed to serve as preferred migration pathways. The identification of preferred contaminant migration pathways within the Y-12 Plant area is essential and required to refine the current Bear Creek Valley groundwater conceptual model and to assist in the selection of technically feasible and cost effective remedial strategies. This report presents the results of an initial investigation of the occurrence of manmade (anthropogenic) fill and its effect upon groundwater movement within the plant area. These interpretations are subject to revision and improvement as further investigation of the effects of the fill upon contaminant migration progresses

  11. Analysis of Material Removal and Surface Characteristics in Machining Multi Walled Carbon Nanotubes Filled Alumina Composites by WEDM Process

    Directory of Open Access Journals (Sweden)

    Annebushan Singh Meinam

    2017-01-01

    Full Text Available The reinforcement of ceramic materials with electrically conductive particles increases the overall conductivity of the ceramic material. This allows the ceramic material to be more readily machined using wire electrical discharge machining process. The current work is an approach to identify the machinability of multi walled carbon nanotubes filled alumina composites in wire electrical discharge machining process. Alumina samples of 5 vol. % and 10 vol. % multi walled carbon nanotubes are machined and analysed for material removal rate and the surface characteristics. An increase in material removal rate is observed with increase in filler concentrations. At the same time, better surface roughness is observed. The surface characteristics of composite alumina are further compared with Monel 400 alloy. It has been observed that spalling action is the dominating material removal mechanism for alumina composites, while melting and evaporation is for the Monel 400 alloy.

  12. Characterisation of bentonites from Kutch, India and Milos, Greece - some candidate tunnel back-fill materials?

    International Nuclear Information System (INIS)

    Olsson, Siv; Karnland, Ola

    2009-12-01

    During the past decades comprehensive investigations have been made on bentonite clays in order to find optimal components of the multi-barrier system of repositories for radioactive waste. The present study gives a mineralogical characterisation of some selected bentonites, in order to supply some of the necessary background data on the bentonites for evaluating their potential as tunnel back-fill materials. Two bentonites from the island of Milos, Greece (Milos BF 04 and BF 08), and two bentonites from Kutch, India (Kutch BF 04 and BF 08) were analysed for their grain size distribution, cation exchange properties and chemical composition. The mineralogical composition was determined by X-ray diffraction analysis and evaluated quantitatively by use of the Siroquant software. Both the bulk bentonite and the 63 μm. The bentonite is distinguished by a high content of dolomite and calcite, which make up almost 25% of the bulk sample. The major accessory minerals are K-feldspars and plagioclase, whereas the content of sulphur-bearing minerals is very low (0.06% total S). Smectite makes up around 60% of the bulk sample, which has a CEC value of 73 meq/100 g. The pool of interlayer cations has a composition Mg>Ca>>Na>>K. The X-ray diffraction characteristics and the high potassium content (1.03% K 2 O) of the Na>Mg>>K. The 2 O) which indicates that also this smectite may be interstratified with a few percent illitic layers. Based on the charge distribution the smectite should be classified as montmorillonite but in this case Fe predominates over Mg in the octahedral sheet. The structural formula suggests that this smectite has the lowest total layer charge of the smectites examined. Kutch BF 04 contains essentially no particles >63 μm. The bentonite has a high content of titanium and iron-rich accessory minerals, such as anatase, magnetite, hematite and goethite. Other accessory minerals of significance are feldspars and quartz, whereas the content of sulphur

  13. MoS2-Filled PEEK Composite as a Self-Lubricating Material for Aerospace Applications

    Science.gov (United States)

    Theiler, Geraldine; Gradt, Thomas

    2010-01-01

    At BAM, several projects were conducted in the past years dealing with the tribological properties of friction couples at cryogenic temperature and in vacuum environment. Promising candidates for vacuum application are MoS2-filled PEEK/PTFE composites, which showed a friction coefficient as low as 0.03 in high vacuum. To complete the tribological profile of these composites, further tests were performed in ultra-high vacuum (UHV) at room temperature. In this paper, friction and stick slip behavior, as well as outgassing characteristics during the test are presented.

  14. Effectiveness of the ProTaper Universal Retreatment™ system for removing a 10-year-old filling material.

    Science.gov (United States)

    Aguiar, C; Bernart, F; Lima, G; Câmara, A

    2012-01-01

    The aim of the present study was to evaluate the effectiveness of the ProTaper Universal Retreatment™ system and the manual technique for removing a 10-year-old filling material. Twenty mesiobuccal canals of mandibular first molars with curvature degrees ranging from 20° to 35° were instrumented by the Double-Flared Instrumentation Technique with the NitiFlex files. The root canals were dried with sterile paper points and filled with gutta-percha and a zinc oxide-eugenol-based sealer using a cold lateral condensation technique. Accesses to the cavities were temporarily sealed with Cavit. The teeth were embedded in gauze containing saline solution, which was renewed every 2 weeks, and were stored at 37 °C in 100% humidity for 10 years. Buccolingual and mesiodistal radiographs were taken to evaluate the quality of the root canal filling. The radiographs were mounted in slide frames to allow them to be evaluated by the three examiners, who were specialists in endodontics. Only the specimens in whom there was agreement between the three evaluators were included in the study. The specimens were divided into 2 groups with 10 root canals each, according to gutta-percha removal techniques: Group 1: ProTaper Universal Retreatment™ system; Group 2: Hedström and K-files. Buccolingual and mesiodistal radiographs were taken and evaluated by three examiners who determined the effectiveness of the removal of the filling material. The presence of material was measured according to a score scale. Data were analyzed statistically by Fisher's exact test at 5% significance level. There were no statistical differences between the two methods in the coronal (P=0.211), and middle (P=0.266) thirds, but there were statistical differences between the two methods in the apical third (P=0.038). Not one of the experimental techniques promoted complete removal of the filling materials. The manual technique with K-file and Hedström files achieved better results than the Pro

  15. Characterisation of bentonites from Kutch, India and Milos, Greece - some candidate tunnel back-fill materials?

    Energy Technology Data Exchange (ETDEWEB)

    Olsson, Siv; Karnland, Ola (Clay Technology AB, Lund (Sweden))

    2009-12-15

    During the past decades comprehensive investigations have been made on bentonite clays in order to find optimal components of the multi-barrier system of repositories for radioactive waste. The present study gives a mineralogical characterisation of some selected bentonites, in order to supply some of the necessary background data on the bentonites for evaluating their potential as tunnel back-fill materials. Two bentonites from the island of Milos, Greece (Milos BF 04 and BF 08), and two bentonites from Kutch, India (Kutch BF 04 and BF 08) were analysed for their grain size distribution, cation exchange properties and chemical composition. The mineralogical composition was determined by X-ray diffraction analysis and evaluated quantitatively by use of the Siroquant software. Both the bulk bentonite and the <1mum fraction were analyzed when relevant. Prior to the chemical analyses the <1 mum fractions were converted to homo-ionic clays and purified by dialysis. The chemical data were used for calculating the structural formula of the smectites. Milos BF 04 contains ca. 10% particles >63 mum. The bentonite is distinguished by a high content of dolomite and calcite, which make up almost 25% of the bulk sample. The major accessory minerals are K-feldspars and plagioclase, whereas the content of sulphur-bearing minerals is very low (0.06% total S). Smectite makes up around 60% of the bulk sample, which has a CEC value of 73 meq/100 g. The pool of interlayer cations has a composition Mg>Ca>>Na>>K. The X-ray diffraction characteristics and the high potassium content (1.03% K{sub 2}O) of the <1 mum fraction suggest that the smectite is interstratified with ca. 10% illitic layers. Based on the charge distribution the smectite should be classified as montmorillonite and according to the structural formula, Mg predominates over Fe in the octahedral sheet. However, remnants of Mg-carbonates, if present, may be a source of error in the formula calculation. Milos BF 08 has a

  16. 5-year results comparing mineral trioxide aggregate and adhesive resin composite for root-end sealing in apical surgery

    DEFF Research Database (Denmark)

    von Arx, Thomas; Hänni, Stefan; Jensen, Simon Storgård

    2014-01-01

    was designed to re-examine a large sample of teeth treated with apical surgery after 5 years. METHODS: Patients were recalled 5 years after apical surgery, and treated teeth were classified as healed or not healed based on clinical and radiographic examination. (The latter was performed independently by 3......, age, type of tooth treated, post/screw, type of surgery). CONCLUSIONS: The results from this prospective nonrandomized clinical study with a 5-year follow-up of 271 teeth indicate that MTA exhibited a higher healing rate than COMP in the longitudinal prognosis of root-end sealing.......INTRODUCTION: Recent meta-analyses of the outcome of apical surgery using modern techniques including microsurgical principles and high-power magnification have yielded higher rates of healing. However, the information is mainly based on 1- to 2-year follow-up data. The present prospective study...

  17. The Effect of Resection Angle on Stress Distribution after Root-End Surgery

    Science.gov (United States)

    Monteiro, Jaiane Bandoli; Dal Piva, Amanda Maria de Oliveira; Tribst, João Paulo Mendes; Borges, Alexandre Luiz Souto; Tango, Rubens Nisie

    2018-01-01

    Introduction: This study aimed to investigate the influence of the resection angle on the stress distribution of retrograde endodontic treated maxillary incisors under oblique-load application. Methods and Materials: A maxillary central incisor which was endodontically treated and restored with a fiber glass post was obtained in a 3-dimensional numerical model and distributed into three groups according to type of resection: control; restored with fiber post without retrograde obturation, R45 and R90 with 45º and 90º resection from tooth axial axis, respectively and restored with Fuji II LC (GC America). The numerical models received a 45º occlusal load of 200 N/cm2 on the middle of lingual surface. All materials and structures were considered linear elastic, homogeneous and isotropic. Numerical models were plotted and meshed with isoparametric elements, and the results were analyzed using maximum principal stress (MPS). Results: MPS showed greater stress values in the bone tissue for control group than the other groups. Groups with apicectomy showed acceptable stress distribution on the fiber post, cement layer and root dentin, presenting more improved values than control group. Conclusion: Apicectomy at 90º promotes more homogeneity on stress distribution on the fiber post, cement layer and root dentin, which suggests less probability of failure. However, due to its facility and stress distribution also being better than control group, apicectomy at 45° could be a good choice for clinicians. PMID:29707013

  18. Entropy generation in Poiseuille flow through a channel partially filled with a porous material

    Directory of Open Access Journals (Sweden)

    Kumar Vikas

    2015-01-01

    Full Text Available In the present paper, a theoretical analysis of entropy generation due to fully developed flow and heat transfer through a parallel plate channel partially filled with a porous medium under the effect of transverse magnetic field and radiation is presented. Both horizontal plates of the channel are kept at constant and equal temperature. An exact solution of governing equation for both porous and clear fluid regions has been obtained in closed form. The entropy generation number and the Bejan number are also calculated. The effects of various parameters such as magnetic field parameter, radiation parameter, Brinkman number, permeability parameter, ratios of viscosities and thermal conductivities are examined on velocity, temperature, entropy generation rate.

  19. Glucose reactivity with filling materials as a limitation for using the glucose leakage model

    NARCIS (Netherlands)

    Shemesh, H.; Souza, E.M.; Wu, M.K.; Wesselink, P.R.

    2008-01-01

    Aim To evaluate the reactivity of different endodontic materials and sealers with glucose and to asses the reliability of the glucose leakage model in measuring penetration of glucose through these materials. Methodology Ten uniform discs (radius 5 mm, thickness 2 mm) were made of each of the

  20. Computerized simulation of the mechanical behavior of wood-filled shock absorbers of radioactive materials transport casks

    International Nuclear Information System (INIS)

    Neumann, Martin; Wille, Frank

    2011-01-01

    In Germany the mechanical component inspection of transport containers for radioactive materials is performed by BAM (Bundesanstalt fuer Materialforschung und -pruefung) under consideration of national and international standards and guidelines. Experimental and calculative (analytical and numerical) techniques combined with material and/or component testing are the basis of assessment concepts according the state of the art. The authors describe the experiences of BAM concerning assessment and description of the mechanical behavior of shock absorbing components, including modeling strategies, material models, drop tests and experiment-calculation comparison. Energy absorbing components are used to reduce the impact forces at the container in case of a transport accident. In Germany wood filled thin-walled constructions are used. The deformation behavior of the wood is a main part of the calculative simulation procedures in comparison with experimental tests.

  1. Wide band design on the scaled absorbing material filled with flaky CIPs

    Science.gov (United States)

    Xu, Yonggang; Yuan, Liming; Gao, Wei; Wang, Xiaobing; Liang, Zichang; Liao, Yi

    2018-02-01

    The scaled target measurement is an important method to get the target characteristic. Radar absorbing materials are widely used in the low detectable target, considering the absorbing material frequency dispersion characteristics, it makes designing and manufacturing scaled radar absorbing materials on the scaled target very difficult. This paper proposed a wide band design method on the scaled absorbing material of the thin absorption coating with added carbonyl iron particles. According to the theoretical radar cross section (RCS) of the plate, the reflection loss determined by the permittivity and permeability was chosen as the main design factor. Then, the parameters of the scaled absorbing materials were designed using the effective medium theory, and the scaled absorbing material was constructed. Finally, the full-size coating plate and scaled coating plates (under three different scale factors) were simulated; the RCSs of the coating plates were numerically calculated and measured at 4 GHz and a scale factor of 2. The results showed that the compensated RCS of the scaled coating plate was close to that of the full-size coating plate, that is, the mean deviation was less than 0.5 dB, and the design method for the scaled material was very effective.

  2. Thermal Protection Performance of Carbon Aerogels Filled with Magnesium Chloride Hexahydrate as a Phase Change Material

    Directory of Open Access Journals (Sweden)

    Ali Kazemi

    2014-02-01

    Full Text Available Carbon aerogels are comprised of a class of low density open-cell foams with large void space, nanometer pore size and composed of sparsely semi-colloidal nanometer sized particles forming an open porous structure. Phase change materials are those with high heat of fusion that could absorb and release a large amount of energy at the time of phase transition. These materials are mostly used as thermal energy storage materials but in addition they could serve as an obstacle for passage of heat during phase changes and this has led to their use in thermal protection systems. In this study, the effect of magnesium chloride hexahydrate, as a phase change material (melting point 115°C, on thermal properties of carbon aerogels is investigated. Thermal performance tests are designed and used for comparing the temperature-time behavior of the samples. DSC is applied to obtain the latent heat of melting of the phase change materials and the SEM tests are used to analyze the microstructure and morphology of carbon aerogels. The results show that the low percentage of phase change materials in carbon aerogels does not have any significant positive effect on carbon aerogels thermal properties. However, these properties are improved by increasing the percentage of phase change materials. With high percentage of phase change materials, a sample surface at 300°C would display an opposite surface with a significant drop in temperature increases, while at 115-200°C, with carbon aerogels, having no phase change materials, there is a severe reduction in the rate of temperature increase of the sample.

  3. Algal growth inhibition test in filled, closed bottles for volatile and sorptive materials

    DEFF Research Database (Denmark)

    Mayer, Philipp; Nyholm, Niels; Verbruggen, Eric M. J.

    2000-01-01

    Exposure concentrations of many hydrophobic substances are difficult to maintain in algal growth inhibition tests performed in open agitated flasks. This is partly because such compounds tend to volatilize from aqueous solution and partly because of sorption to the algal biomass as well as to the......Exposure concentrations of many hydrophobic substances are difficult to maintain in algal growth inhibition tests performed in open agitated flasks. This is partly because such compounds tend to volatilize from aqueous solution and partly because of sorption to the algal biomass as well......, and the resulting dissolved CO2 concentration supported maximum algal growth rates without pH drift for algal densities up to 4 mg dry weight/L. Two-day toxicity tests with kerosene were performed with this new test design and compared with an open bottle test and with a closed bottle test with headspace. Exposure...... concentrations of the volatile fraction of kerosene decreased by 99% in the open test, by 77% in the closed flask test with headspace, and by 16% in the filled closed bottle test. Algal growth inhibition was observed at much lower additions of kerosene in the new test design because of the improved maintenance...

  4. Systematic review of "filling" procedures for lip augmentation regarding types of material, outcomes and complications.

    Science.gov (United States)

    San Miguel Moragas, Joan; Reddy, Rajgopal R; Hernández Alfaro, Federico; Mommaerts, Maurice Y

    2015-07-01

    The ideal lip augmentation technique provides the longest period of efficacy, lowest complication rate, and best aesthetic results. A myriad of techniques have been described for lip augmentation, but the optimal approach has not yet been established. This systematic review with meta-regression will focus on the various filling procedures for lip augmentation (FPLA), with the goal of determining the optimal approach. A systematic search for all English, French, Spanish, German, Italian, Portuguese and Dutch language studies involving FPLA was performed using these databases: Elsevier Science Direct, PubMed, Highwire Press, Springer Standard Collection, SAGE, DOAJ, Sweetswise, Free E-Journals, Ovid Lippincott Williams & Wilkins, Willey Online Library Journals, and Cochrane Plus. The reference section of every study selected through this database search was subsequently examined to identify additional relevant studies. The database search yielded 29 studies. Nine more studies were retrieved from the reference sections of these 29 studies. The level of evidence ratings of these 38 studies were as follows: level Ib, four studies; level IIb, four studies; level IIIb, one study; and level IV, 29 studies. Ten studies were prospective. This systematic review sought to highlight all the quality data currently available regarding FPLA. Because of the considerable diversity of procedures, no definitive comparisons or conclusions were possible. Additional prospective studies and clinical trials are required to more conclusively determine the most appropriate approach for this procedure. IV. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  5. Castor oil polyurethane containing silica nanoparticles as filling material of bone defect in rats.

    Science.gov (United States)

    Nacer, Renato Silva; Poppi, Rodrigo Ré; Carvalho, Paulo de Tarso Camilo de; Silva, Baldomero Antonio Kato da; Odashiro, Alexandre Nakao; Silva, Iandara Schettert; Delben, José Renato Jurkevicz; Delben, Angela Antonia Sanches Tardivo

    2012-01-01

    To evaluate the biologic behavior of the castor polymer containing silica nanoparticles as a bone substitute in diafisary defect. Twenty seven male Rattus norvegicus albinus Wistar lineage were submitted to bone defect filled with castor oil polymer. Three experimental groups had been formed with nine animals each: (1) castor oil polymer containing only calcium carbonate; (2) castor oil polymer with calcium carbonate and doped with 5% of silica nanoparticles; (3) castor polymer with calcium carbonate doped with 10% of silica nanoparticles; 3 animals of each group were submitted to euthanasia 15, 30 and 60 days after experimental procedure, and their femurs were removed to histological evaluation. there was bone growth in all the studied groups, with a greater tendency of growth in the group 1. After 30 days all the groups presented similar results. After 60 days a greater amount of fibroblasts, osteoblasts, osteocytes and osteoclasts in group 3 was observed, with integrated activity of 3 kinds of cells involved in the bone activation-reabsorption-formation. The castor polymer associated to the silica nanoparticles is biocompatible and allows osteoconduction. The presence of osteoprogenitors cells suggests silica osteoinduction capacity.

  6. Evaluation of simulation learning materials use to fill the gap in Japanese dental English education.

    Science.gov (United States)

    Seki, Naoko; Moross, Janelle; Sunaga, Masayo; Hobo, Koki; Miyoshi, Tomoe; Nitta, Hiroshi; Kinoshita, Atsuhiro; Morio, Ikuko

    2016-01-01

    Even though English is most frequently the common language when the patient's native language differs from that of a dentist, the opportunities for Japanese undergraduate dental students to learn dental English are now quite limited. The purposes of our study were to investigate: the effectiveness and feasibility of the computer-assisted simulation materials as one solution strategy for dental English education in Japan, and the needs and demands for dental English from the learners' side. Interactive simulation materials for medical interviews in English and clinical cases which were translated to English, were delivered via Learning Management System (LMS) to nineteen trainee residents of dentistry (residents). Evaluation for the materials, learners' knowledge and interests in the contents, and ease of operation were obtained by post-questionnaire (response rates were 100% and 95%, respectively). Both questionnaire-surveys received positive feedback toward the materials, yet 47% answered that they lacked the level of knowledge about contents of the medical interview in English. Results were sufficient to suggest that the residents would like to have the opportunity to study or practice medical interview in English, or English related to dentistry, and that the simulation materials could be one of the solution strategies for opportunity provision.

  7. In vivo Evaluation of Marginal Microgaps of Sheep Incisors filled with Two Composite Materials

    Directory of Open Access Journals (Sweden)

    Mária Figurová

    2009-01-01

    Full Text Available The aim of the study was to evaluate the marginal microgaps of two light-induced polymerization composite materials: Filtek P60 (3M ESPE and Opticor New (Spofa Dental in ovine teeth in vivo. The restorative materials were placed to type A-cavity to buccal surfaces of permanent teeth (Triadan system 301, 302, 303, 401, 402, 403. The variables of composite materials were evaluated in 3 groups of animals, 2 animals in each, at different time intervals (1, 6 and 9 months after beginning of the experiment. In various time intervals, 12 teeth per group were extracted under general injection anaesthesia, 6 teeth from each animal. Altogether 36 teeth were extracted throughout the experiment. During the experiment we observed neither cracks nor marginal discoloration in both Filtek P60 and Opticor New restorations. Retention of all restorations was 100%. Significant (P = 0.029 ANOVA differences were observed in the dentin with Filtek P60 packable restorations which exhibited smaller marginal microgaps (OPTICOR NEW and dentin 11.09 mm, FILTEK P60 and dentin 5.64 μm. The mean size of microgaps between dentin and the packable composite material Filtek P60 was significantly lower (P = 0.029 ANOVA in comparison with the microhybrid Opticor New composite restorations. These materials are suitable as permanent restoration of dental cervical caries in sheep and other herbivores, such as those kept in zoological gardens and companion animals.

  8. Mechanical and thermal properties of hydroxyapatite filled poly(methyl methacrylate) heat processed denture base material

    International Nuclear Information System (INIS)

    Mohamed, S.H.; Arifin, A.; Mohd Ishak, Z.A.; Nizam, A.; Samsudin, A.R.

    2004-01-01

    The aim of this study was to evaluate the effect of powder-to-liquid ratio on the glass transition temperature (Tg) and the tensile properties of denture base material prepared from poly (methyl methacrylate) (PMMA) and hydroxyapatite (HA) previously treated with 3-trimethoxysilylpropyl methacrylate (γ-MPS). Specimens for, mechanical testing were prepared by adding composites powder (PMMA, BPO and RA) to the monomer (MMA and EGDMA) followed by hand mixing as in dental laboratory description usage. The glass transition temperature was studied by using differential scanning calorimetry (DSQ. It was observed that the tensile properties and the Tg were affected by the powder-to-liquid ratio. The mechanical characterization of the materials were performed by using single edge notch-tension (SEN-T) specimens; the fracture toughness was slightly higher in formulation which contained RA filler compared to commercial denture base material. (Author)

  9. 40 CFR 230.60 - General evaluation of dredged or fill material.

    Science.gov (United States)

    2010-07-01

    ... (previous tests, the presence of polluting industries and information about their discharge or runoff into... is most likely to be free from chemical, biological, or other pollutants where it is composed... industries, municipalities, or other sources, including types and amounts of waste materials discharged along...

  10. Cuspal deflection and microleakage in premolar teeth restored with bulk-fill flowable resin-based composite base materials

    DEFF Research Database (Denmark)

    Moorthy, A; Hogg, C H; Dowling, A H

    2012-01-01

    To assess the cuspal deflection and cervical microleakage of standardised Class II cavities incrementally filled with a dimethacrylate RBC or bulk-fill flowable RBC bases.......To assess the cuspal deflection and cervical microleakage of standardised Class II cavities incrementally filled with a dimethacrylate RBC or bulk-fill flowable RBC bases....

  11. Anisotropic local physical properties of human dental enamel in comparison to properties of some common dental filling materials.

    Science.gov (United States)

    Raue, Lars; Hartmann, Christiane D; Rödiger, Matthias; Bürgers, Ralf; Gersdorff, Nikolaus

    2014-11-01

    A major aspect in evaluating the quality of dental materials is their physical properties. Their properties should be a best fit of the ones of dental hard tissues. Manufacturers give data sheets for each material. The properties listed are characterized by a specific value. This assumes (but does not prove) that there is no direction dependence of the properties. However, dental enamel has direction-dependent properties which additionally vary with location in the tooth. The aim of this paper is to show the local direction dependence of physical properties like the elastic modulus or the thermal expansion in dental hard tissues. With this knowledge the 'perfect filling/dental material' could be characterized. Enamel sections of ∼400-500 μm thickness have been cut with a diamond saw from labial/buccal to palatal/lingual (canine, premolar and molar) and parallel to labial (incisor). Crystallite arrangements have been measured in over 400 data points on all types of teeth with x-ray scattering techniques, known from materials science. X-ray scattering measurements show impressively that dental enamel has a strong direction dependence of its physical properties which also varies with location within the tooth. Dental materials possess only little or no property direction dependence. Therefore, a mismatch was found between enamel and dental materials properties. Since dental materials should possess equal (direction depending) properties, worthwhile properties could be characterized by transferring the directional properties of enamel into a property 'wish list' which future dental materials should fulfil. Hereby the 'perfect dental material' can be characterized.

  12. Experimental evaluation and design of unfilled and concrete-filled FRP composite piles : Task 4B : material & construction specifications : final report.

    Science.gov (United States)

    2015-07-01

    The overall goal of this project is the experimental evaluation and design of unfilled and concrete-filled FRP composite piles for load-bearing in bridges. This report covers Task 4B, Materials and Construction Specifications. : This technical report...

  13. Comparing ProFile Vortex to ProTaper Next for the efficacy of removal of root filling material: An ex vivo micro-computed tomography study

    Directory of Open Access Journals (Sweden)

    Emad AlShwaimi

    2018-01-01

    Conclusion: Our findings suggest that PV is as effective as PTN for removal of root canal filling material. Therefore, PV can be considered for use in endodontic retreatment, although more effective files or techniques are still required.

  14. Sealing ability of cermet ionomer cement as a retrograde filling material.

    Science.gov (United States)

    Aktener, B O; Pehlivan, Y

    1993-03-01

    An in vitro dye leakage study was performed to compare the sealing ability of high copper amalgam with cavity varnish and cermet ionomer cement with and without varnish when used as retrofilling materials. The root canals of 54 maxillary anterior teeth were instrumented and obturated with gutta-percha and sealer. The apical 3 mm of the roots were resected and apical class I cavity preparations were made. The roots were then randomly divided into three groups and retrofilled with one of the experimental materials. After 72 h of immersion in India ink, the roots were cleared and evaluated for leakage with a stereomicroscope. Statistical analysis indicated that the cermet ionomer cement with varnish group had significantly less leakage than the amalgam group (P cermet ionomer cement without varnish group (P 0.05).

  15. Robust synthesis of epoxy resin-filled microcapsules for application to self-healing materials.

    Science.gov (United States)

    Bolimowski, Patryk A; Bond, Ian P; Wass, Duncan F

    2016-02-28

    Mechanically and thermally robust microcapsules containing diglycidyl ether bisphenol A-based epoxy resin and a high-boiling-point organic solvent were synthesized in high yield using in situ polymerization of urea and formaldehyde in an oil-in-water emulsion. Microcapsules were characterized in terms of their size and size distribution, shell surface morphology and thermal resistance to the curing cycles of commercially used epoxy polymers. The size distribution of the capsules and characteristics such as shell thickness can be controlled by the specific parameters of microencapsulation, including concentrations of reagents, stirrer speed and sonication. Selected microcapsules, and separated core and shell materials, were analysed using thermogravimetric analysis and differential scanning calorimetry. It is demonstrated that capsules lose minimal 2.5 wt% at temperatures no higher than 120°C. These microcapsules can be applied to self-healing carbon fibre composite structural materials, with preliminary results showing promising performance. © 2016 The Author(s).

  16. Sound transmission through panels and shells filled with porous material in the presence of external flow

    OpenAIRE

    Zhou, Jie

    2014-01-01

    With increasingly tighter regulations on noise exposure during flight, aircraft designers have been compelled to innovate structures that minimise noise transmission into the cabin space. Porous material is widely used as a passive noise control medium because of their light weight, low cost, and broad band sound abatement effectiveness. The present work, inspired by the need to be able to predict noise transmission characteristics for commonly used constructions, incorporates the effect of f...

  17. Microleakage of conventional, resin-modified, and nano-ionomer glass ionomer cement as primary teeth filling material

    Directory of Open Access Journals (Sweden)

    Dita Madyarani

    2014-12-01

    Full Text Available Background: Glass ionomer cements are one of many dental materials that widely used in pediatric dentistry due to their advantage of fluoride release and chemical bond to tooth structure. Adherence of the filling material to the cavity walls is one of the most important characteristic that need to be examined its effect on microleakage. Purpose: This study was conducted to examine the microleakage of nano-ionomer glass ionomer cement compared with the conventional and resin-modified glass ionomer cements. Methods: Standard class V cavities sized 3 mm x 2 mm x 2 mm were made on a total of 21 extracted maxillary primary canine teeth and restored with the conventional, resin-modified, dan nano-ionomer glass ionomer cements. All the teeth were immersed in a 2% methylene blue dye for 4 hours. The depth of dye penetration was assessed using digital microscope after sectioning the teeth labio-palatally. The results were statistically analyzed using Kruskal-Wallis test. Results: All type of glass ionomer material showed microleakage. Conventional glass ionomer cement demonstrated the least microleakage with mean score 1.29. the resin-modified glass ionomer cements (mean score 1.57 and nano-ionomer glass ionomer cement (mean score 2.57. Conclusion: The conventional glassionomer, resin modified glassionomer, and nano-ionomer glassionomer showed micro leakage as filling material in primary teeth cavity. The micro leakage among three types was not significant difference. All three material were comparable in performance and can be used for filling material but still needs a coating material to fill the microleakage.Latar belakang: Semen ionomer kaca adalah salah satu dari banyak bahan gigi yang banyak digunakan dalam praktek kedokteran gigi anak karena bahan tersebut merilis fluoride dan berikatan kimia dengan struktur gigi. Perlekatan bahan tumpatan pada dinding kavitas adalah salah satu karakteristik paling penting yang perlu diteliti efeknya terhadap

  18. Chemical properties of gutta-percha endodontic filling material: investigation of five commercial brands; Propriedades quimicas de cones de guta-percha: avaliacao de diferentes marcas comerciais

    Energy Technology Data Exchange (ETDEWEB)

    Silva Junior, Joao Batista A.; Paula, Regina C.M.; Feitosa, Judith P.A. [Ceara Univ., Fortaleza, CE (Brazil). Dept. de Quimica Organica e Inorganica]. E-mail: juniorquim@yahoo.com.br; rpaula@dqoi.ufc.br; judith@dqoi.ufc.br; Gurgel Filho, Eduardo; Teixeira, Fabricio B [Universidade Estadual de Campinas, Piracicaba, SP (Brazil). Faculdade de Odontologia.Dept. de Odontologia Restauradora]. E-mail: gurgeleduardo@aol.com

    2001-07-01

    Chemical composition e thermal stability of five brands of gutta-percha endodontic filling material were investigated. Samples with higher amount of organic materials possess higher thermal stability. Investigation of gutta-percha polymer extracted from the endodontic filling by IR and NMR shows that the polymer is predominantly trans-polyisoprene. The thermal stability and molar mass were similar for four brands, however the 'Tanari' brand has got lower molar mass value than the other ones. (author)

  19. Kinetics of apatite formation on a calcium-silicate cement for root-end filling during ageing in physiological-like phosphate solutions.

    Science.gov (United States)

    Gandolfi, Maria Giovanna; Taddei, Paola; Tinti, Anna; De Stefano Dorigo, Elettra; Rossi, Piermaria Luigi; Prati, Carlo

    2010-12-01

    The bioactivity of calcium silicate mineral trioxide aggregate (MTA) cements has been attributed to their ability to produce apatite in presence of phosphate-containing fluids. This study evaluated surface morphology and chemical transformations of an experimental accelerated calcium-silicate cement as a function of soaking time in different phosphate-containing solutions. Cement discs were immersed in Dulbecco's phosphate-buffered saline (DPBS) or Hank's balanced salt solution (HBSS) for different times (1-180 days) and analysed by scanning electron microscopy connected with an energy dispersive X-ray analysis (SEM-EDX) and micro-Raman spectroscopy. SEM-EDX revealed Ca and P peaks after 14 days in DPBS. A thin Ca- and P-rich crystalline coating layer was detected after 60 days. A thicker multilayered coating was observed after 180 days. Micro-Raman disclosed the 965-cm(-1) phosphate band at 7 days only on samples stored in DPBS and later the 590- and 435-cm(-1) phosphate bands. After 60-180 days, a layer approximately 200-900 μm thick formed displaying the bands of carbonated apatite (at 1,077, 965, 590, 435 cm(-1)) and calcite (at 1,088, 713, 280 cm(-1)). On HBSS-soaked, only calcite bands were observed until 90 days, and just after 180 days, a thin apatite-calcite layer appeared. Micro-Raman and SEM-EDX demonstrated the mineralization induction capacity of calcium-silicate cements (MTAs and Portland cements) with the formation of apatite after 7 days in DPBS. Longer time is necessary to observe bioactivity when cements are immersed in HBSS.

  20. Establishment of characterizing parameters of clay as a filling material and coverage for repository

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Daisy M.M. dos; Tello, Cledola Cassia Oliveira de, E-mail: dmms@cdtn.br, E-mail: tellocc@cdtn.br [Centro de Desenvolvimento da Tecnologia Nucelar (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2015-07-01

    The multiple barriers of a repository should be able to provide adequate containment of radionuclides during all the previewed time for the operation and institutional control. One of these barriers is the backfill layer, located between the waste packages and other barriers. Furthermore, after shutting the disposal units with concrete, various materials are used to compose the final coverage of the deposition area. The backfill and the cover layer can be composed of clay or clay mixed with cement, with soil or with rocks. The last layer is a vegetation cover. The selection of the best clay should take into consideration some physical-chemical and mechanical properties. Bentonite is a clay with high absorption capacity, and large volume change in moistening and drying processes, being also effective in the contaminant retention. Additionally, it presents unique properties, such as high swelling potential. Some bentonite characterization works have been developed in the Laboratory of Cementation at CDTN/CNEN (LABCIM/CDTN). The sequence of experiments was: granulometric analysis, moisture, compaction test, hydraulic conductivity and cation exchange capacity. Some initial characterization results are presented and discussed. The paper summarizes these previous studies in order to have the basis for creating a protocol for characterization of a bentonite as a reference material. (author)

  1. Establishment of characterizing parameters of clay as a filling material and coverage for repository

    International Nuclear Information System (INIS)

    Santos, Daisy M.M. dos; Tello, Cledola Cassia Oliveira de

    2015-01-01

    The multiple barriers of a repository should be able to provide adequate containment of radionuclides during all the previewed time for the operation and institutional control. One of these barriers is the backfill layer, located between the waste packages and other barriers. Furthermore, after shutting the disposal units with concrete, various materials are used to compose the final coverage of the deposition area. The backfill and the cover layer can be composed of clay or clay mixed with cement, with soil or with rocks. The last layer is a vegetation cover. The selection of the best clay should take into consideration some physical-chemical and mechanical properties. Bentonite is a clay with high absorption capacity, and large volume change in moistening and drying processes, being also effective in the contaminant retention. Additionally, it presents unique properties, such as high swelling potential. Some bentonite characterization works have been developed in the Laboratory of Cementation at CDTN/CNEN (LABCIM/CDTN). The sequence of experiments was: granulometric analysis, moisture, compaction test, hydraulic conductivity and cation exchange capacity. Some initial characterization results are presented and discussed. The paper summarizes these previous studies in order to have the basis for creating a protocol for characterization of a bentonite as a reference material. (author)

  2. Modification induced by laser irradiation on physical features of plastics materials filled with nanoparticles

    Directory of Open Access Journals (Sweden)

    Scolaro Cristina

    2018-01-01

    Full Text Available The Thermal Laser Welding (TLW process involves localized heating at the interface of two pieces of plastic that will be joined. Polymeric materials of Ultra High Molecular Weight Polyethylene (UHMWPE, both pure and containing nanostructures at different concentrations (titanium and silver nanoparticles, were prepared as thin foils in order to produce an interface between a substrate transparent to the infrared laser wavelength and an highly absorbent substrate, in order to be welded by the laser irradiation. The used diode laser operates at 970 nm wavelength, in continuum, with a maximum energy of 100 mJ, for times of the order of 1 -60 s, with a spot of 300 μm of diameter. The properties of the polymers and of nanocomposite sheets, before and after the laser welding process, were measured in terms of optical characteristics, wetting ability, surface roughness and surface morphology.

  3. Preliminary laboratory assessments of a lightweight geocomposite material for embankment fill application

    Directory of Open Access Journals (Sweden)

    Felix Okonta

    2015-03-01

    Full Text Available The cost of retaining structures used for the lateral support of roadside embankments can be significantly reduced through the use of lightly cemented mixtures of expanded polystyrene (EPS beads and backfill soils as lightweight roadside embankment material. Four grades of residually derived sandy soils were mixed with EPS beads and the geocomposites were stabilised with 3% cement content, compacted and cured. The textural properties and shear strength parameters of dry and soaked specimens of the cemented geocomposites were determined by direct shear tests. The shear parameters and slope stability charts were used to simulate the slope of typical road embankments. The settlement potentials at different applied normal stresses were also determined. Inclusion of EPS reduced the dry density of the residual soils from an average value of 1790 kg/m3 to 1335 kg/m3. The maximum friction coefficient, tan ᴓ′, mobilised by the geocomposite specimens decreased with an increase in the soil fines content (>0.425 mm. The difference in tan ᴓ′ between the stabilised geocomposites and the natural soil was also dependent on the fines content. For an embankment height of 20 m, slope angles of 38° and 62° were determined for fine sand geocomposites in fully saturated drainage and drained conditions, respectively. Lower slope angles were determined for geocomposites made from silty, coarse and gravelly sands. A limiting embankment height of 50 m was determined for the four geocomposites. Rainfall-induced settlement of geocomposites was dependent on pre-inundation stiffness; for the range of applied stress up to 200 kPa, the settlement exhibited by the fine and silty sand geocomposites was lower than that for the coarse and gravelly sand geocomposites. Fine and silty sands make poor materials for slope embankments because of their poor hydraulic conductivity; however, fine and silty sand geocomposites have a good conductivity and friction angle to support

  4. The Effect of Hole Transport Material Pore Filling on Photovoltaic Performance in Solid-State Dye-Sensitized Solar Cells

    KAUST Repository

    Melas-Kyriazi, John

    2011-04-05

    A detailed investigation of the effect of hole transport material (HTM) pore filling on the photovoltaic performance of solid-state dye-sensitized solar cells (ss-DSCs) and the specific mechanisms involved is reported. It is demonstrated that the efficiency and photovoltaic characteristics of ss-DSCs improve with the pore filling fraction (PFF) of the HTM, 2,2\\',7,7\\'-tetrakis-(N, N-di-p-methoxyphenylamine)9,9\\'-spirobifluorene(spiro-OMeTAD). The mechanisms through which the improvement of photovoltaic characteristics takes place were studied with transient absorption spectroscopy and transient photovoltage/photocurrent measurements. It is shown that as the spiro-OMeTAD PFF is increased from 26% to 65%, there is a higher hole injection efficiency from dye cations to spiro-OMeTAD because more dye molecules are covered with spiro-OMeTAD, an order-of-magnitude slower recombination rate because holes can diffuse further away from the dye/HTM interface, and a 50% higher ambipolar diffusion coefficient due to an improved percolation network. Device simulations predict that if 100% PFF could be achieved for thicker devices, the efficiency of ss-DSCs using a conventional rutheniumdye would increase by 25% beyond its current value. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. The Effect of Hole Transport Material Pore Filling on Photovoltaic Performance in Solid-State Dye-Sensitized Solar Cells

    KAUST Repository

    Melas-Kyriazi, John; Ding, I-Kang; Marchioro, Arianna; Punzi, Angela; Hardin, Brian E.; Burkhard, George F.; Té treault, Nicolas; Grä tzel, Michael; Moser, Jacques-E.; McGehee, Michael D.

    2011-01-01

    A detailed investigation of the effect of hole transport material (HTM) pore filling on the photovoltaic performance of solid-state dye-sensitized solar cells (ss-DSCs) and the specific mechanisms involved is reported. It is demonstrated that the efficiency and photovoltaic characteristics of ss-DSCs improve with the pore filling fraction (PFF) of the HTM, 2,2',7,7'-tetrakis-(N, N-di-p-methoxyphenylamine)9,9'-spirobifluorene(spiro-OMeTAD). The mechanisms through which the improvement of photovoltaic characteristics takes place were studied with transient absorption spectroscopy and transient photovoltage/photocurrent measurements. It is shown that as the spiro-OMeTAD PFF is increased from 26% to 65%, there is a higher hole injection efficiency from dye cations to spiro-OMeTAD because more dye molecules are covered with spiro-OMeTAD, an order-of-magnitude slower recombination rate because holes can diffuse further away from the dye/HTM interface, and a 50% higher ambipolar diffusion coefficient due to an improved percolation network. Device simulations predict that if 100% PFF could be achieved for thicker devices, the efficiency of ss-DSCs using a conventional rutheniumdye would increase by 25% beyond its current value. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Study of filling material of dental composites. An analytical approach using radio-activation

    Energy Technology Data Exchange (ETDEWEB)

    Eke, Canel [Akdeniz Univ., Antalya (Turkey). Nuclear Sciences Application and Research Center; Akdeniz Univ., Antalya (Turkey). Div. of Physics Education; Er, Kursat [Akdeniz Univ., Antalya (Turkey). Dept. of Endodontics; Segebade, Christian [Akdeniz Univ., Antalya (Turkey). Nuclear Sciences Application and Research Center; Boztosun, Ismail [Akdeniz Univ., Antalya (Turkey). Nuclear Sciences Application and Research Center; Akdeniz Univ., Antalya (Turkey). Dept. of Physics

    2018-04-01

    The aim of this study is to carry out elemental analyses of dental composites acquired from different producers using photoactivation analysis (PAA). High energy electrons produced by an electron linear accelerator are absorbed by a tungsten disk (Bremsstrahlung converter) thereby producing high energy X-rays (bremsstrahlung). The dental composite materials under study were exposed to the bremsstrahlung radiation whereby radionuclides were produced through photonuclear reactions. Their radioactivities were measured using high resolution semiconductor spectrometers equipped with high purity germanium detectors (HPGe). The spectra were analysed using appropriate computer software. As a result, photonuclear reactions of 12 stable elements were detected in different dental composite species, and the elemental concentrations were calculated. For comparison, the dental composites were also investigated using scanning electron microscopy (SEM) and energy-dispersive X-ray fluorescence spectrometry (EDXRF). Various sizes and shapes of dental composites were observed using SEM. However, contents of dental composites, e.g. Mg, Ni, Ba and Sr were obtained by PAA whilst C, O, Al, S, Ba and Sr were detected by EDXRF spectrometry. The results for Ba and Sr obtained using the two techniques show considerable difference.

  7. Characteristics of low polymerization shrinkage flowable resin composites in newly-developed cavity base materials for bulk filling technique.

    Science.gov (United States)

    Nitta, Keiko; Nomoto, Rie; Tsubota, Yuji; Tsuchikawa, Masuji; Hayakawa, Tohru

    2017-11-29

    The purpose of this study was to evaluate polymerization shrinkage and other physical properties of newly-developed cavity base materials for bulk filling technique, with the brand name BULK BASE (BBS). Polymerization shrinkage was measured according to ISO/FDIS 17304. BBS showed the significantly lowest polymerization shrinkage and significantly higher depth of cure than conventional flowable resin composites (p<0.05). The Knoop hardness, flexural strength and elastic modulus of that were significantly lower than conventional flowable resin composites (p<0.05). BBS had the significantly greatest filler content (p<0.05). SEM images of the surface showed failure of fillers. The lowest polymerization shrinkage was due to the incorporation of a new type of low shrinkage monomer, which has urethane moieties. There were no clear correlations between inorganic filler contents and polymerization shrinkage, flexural strength and elastic modulus. In conclusion, the low polymerization shrinkage of BBS will be useful for cavity treatment in dental clinics.

  8. Coronal leakage of four intracanal medications after exposure to human saliva in the presence of a temporary filling material.

    Science.gov (United States)

    Verissimo, Rebeca Dibe; Gurgel-Filho, Eduardo Diogo; De-Deus, Gustavo; Coutinho-Filho, Tauby; de Souza-Filho, Francisco Jose

    2010-01-01

    To determine the time required for the recontamination of root canals medicated with four different materials. A total of 60 intact, caries-free, human single-rooted teeth with straight roots were selected for this study. After chemo-mechanical preparation they must be changed in the specimens into seven groups: 10 teeth medicated with calcium hydroxide (Ca(OH) 2) + Camphorated paramonochlorophanol (CPMC) (G.1); 10 medicated with 2.5% Sodium hypochlorite (NaOCL) (G.2); 10 medicated with 2% Chlorhexidine gluconate (CHX) in gel (G.3); 10 medicated with 2% CHX in gel + Ca(OH) 2 (G.4); 10 without intracanal medicament and sealed with a coronal temporary filling (G.5). Five teeth were without intracanal medicament and coronally unsealed, used as the positive control group (PC) (G.6) and 5 teeth with intact crowns used as the negative control group (NC) (G.7). Glass vials with rubber stoppers were adjusted for use. The medicaments were prepared and injected into the root canals using sterile plastic syringes. An apparatus was used to evaluate for 30 days leakage. The chamber was filled with 3 ml of human saliva and Brain Heart Infusion (BHI) broth, incubated at 37 degrees C and checked daily for the appearance of turbidity in the BHI broth. Recontamination was detected after an average time of 2.6 days in group 2, 15.9 days in group 3, 30 days in group 1, 27.6 days in group 4, 2.9 days in group 5, 1 day in the positive control, and there was no contamination in the negative control group. The NaOCl group showed the highest worst average of recontamination; on the other hand, high averages were also shown by Ca(OH) 2 + CPMC and Ca(OH) 2 + 2% CHX in gel.

  9. Efficacy of ultrasonic activation of NaOCl and orange oil in removing filling material from mesial canals of mandibular molars with and without isthmus

    Directory of Open Access Journals (Sweden)

    Mirela Sangoi BARRETO

    2015-01-01

    Full Text Available Objectives The aim of this study was to evaluate the volume of remaining filling material after passive ultrasonic irrigation (PUI of sodium hypochlorite (NaOCl and orange oil in mesial canals of mandibular molars, with and without isthmus. Material and Methods Thirty mesial roots of mandibular molars were divided according to the presence or absence of isthmus. Canals were prepared and filled (Micro-CT #1. Filling was removed using rotary instruments, and specimens were sub-divided into three groups according to the irrigation procedures: Conventional – conventional irrigation with NaOCl, PUI/NaOCl – PUI of NaOCl (three activations, 20 seconds each, and PUI/orange oil – PUI of orange oil (Micro-CT#2. Specimens were enlarged using the X2 and X3 ProTaper Next instruments and submitted to the same irrigation protocols (Micro-CT #3. Results No differences were found between the experimental groups in each stage of assessment (P>0.05. The volume of residual filling material was similar to that in Micro-CT #2 and Micro-CT #3, but lower than that observed in Micro-CT #1 (P<0.05. When groups were pooled according to the presence or absence of an isthmus, volume of residual filling material was higher in specimens presenting isthmus (P<0.05. Conclusions PUI of NaOCl or orange oil did not improve filling removal. Isthmus consists in an anatomical obstacle that impairs the removal of filling material.

  10. Heat release, time required, and cleaning ability of MTwo R and ProTaper universal retreatment systems in the removal of filling material.

    Science.gov (United States)

    Bramante, Clovis Monteiro; Fidelis, Natasha Siqueira; Assumpção, Tatiana Santos; Bernardineli, Norberti; Garcia, Roberto Brandão; Bramante, Alexandre Silva; de Moraes, Ivaldo Gomes

    2010-11-01

    This ex vivo study evaluated the heat release, time required, and cleaning efficacy of MTwo (VDW, Munich, Germany) and ProTaper Universal Retreatment systems (Dentsply/Maillefer, Ballaigues, Switzerland) and hand instrumentation in the removal of filling material. Sixty single-rooted human teeth with a single straight canal were obturated with gutta-percha and zinc oxide and eugenol-based cement and randomly allocated to 3 groups (n = 20). After 30-day storage at 37 °C and 100% humidity, the root fillings were removed using ProTaper UR, MTwo R, or hand files. Heat release, time required, and cleaning efficacy data were analyzed statistically (analysis of variance and the Tukey test, α = 0.05). None of the techniques removed the root fillings completely. Filling material removal with ProTaper UR was faster but caused more heat release. Mtwo R produced less heat release than the other techniques but was the least efficient in removing gutta-percha/sealer. ProTaper UR and MTwo R caused the greatest and lowest temperature increase on root surface, respectively; regardless of the type of instrument, more heat was released in the cervical third. Pro Taper UR needed less time to remove fillings than MTwo R. All techniques left filling debris in the root canals. Copyright © 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  11. Efficacy of Different Methods for Removing Root Canal Filling Material in Retreatment - An In-vitro Study.

    Science.gov (United States)

    Kasam, Swetha; Mariswamy, Annapoorna Ballagere

    2016-06-01

    Although success of endodontic therapy has significantly improved in the last few decades due to the introduction of novel materials and techniques, failures of endodontic therapy requiring re-treatment still comprise a significant percentage of patients requiring root canal treatment. To evaluate and compare the effective removal of gutta percha and sealer, amount of apical debris extrusion and time required for gutta percha removal using various endodontic files. Total 48 extracted mandibular premolars were mounted on acrylic blocks and endodontic procedure was carried out using size 40 K file and obturated using guttapercha and zinc oxide eugenol sealer. After one month storage, samples were decoronated, mounted on screw capped vials and subjected to removal of obturated material by four instruments: H files, safe sided H files, protaper universal retreatment rotary system and ultrasonic retreatment tip, grouped as 1, 2, 3, and 4 respectively. Only 2mm of obturated material from the coronal part was removed using no. 3 Gates Glidden drill, guttapercha was softened with a drop of xylene for 2 mins for each canal and retreatment was performed. The retreatment procedure was said to be complete when no visible debris were observed on the instrument flutes. The samples split into two halves and examined under stereomicroscope, photographed, assessed using AUTOCAD software and percentage of remaining filling material in coronal, middle, apical thirds of the canal was calculated in mm(2). Retreatment time was recorded in seconds and apically extruded debris was assessed by microbalance in grams for each tooth. The data was analyzed by using descriptive statistics, ANOVA and Scheffe's post hoc test through SPSS for windows (v 16.0). The ultrasonic retreatment tip had less percentage of residual guttapercha/sealer, shorter mean operating time and little apical extrusion with a significant difference (p<0.05) between the other groups. All techniques retained guttapercha

  12. Properties of n-eicosane-filled microcapsules with different morphology. Phase Change Materials studied by positron spectroscopy and complementary methods

    Energy Technology Data Exchange (ETDEWEB)

    Zgardzińska, B., E-mail: bozena.zgardzinska@poczta.umcs.lublin.pl [Department of Nuclear Methods, Institute of Physics, Maria Curie-Sklodowska University, Pl. M. Curie-Sklodowskiej 1, 20-031 Lublin (Poland); Filipek, M. [Department of Nuclear Methods, Institute of Physics, Maria Curie-Sklodowska University, Pl. M. Curie-Sklodowskiej 1, 20-031 Lublin (Poland); Fortuniak, W. [Center of Molecular and Macromolecular Studies, Polish Academy of Sciences, Sienkiewicza 112, 90-363 Łódź (Poland); Mroczek, P. [Department of Geoecology and Palaeogeography, Faculty of Earth Sciences and Spatial Management, Maria Curie-Sklodowska University, Al. Kraśnicka 2cd, 20-718 Lublin (Poland)

    2016-07-01

    The Positron Annihilation Lifetime Spectroscopy (PALS) was used to investigate properties of selected Phase Change Materials (PCMs) as a function of temperature from 123 K to 333 K. Three different PCM microcapsules investigated in this work were built of n-eicosane filling and a siloxane polymer as a shell material. It has been found that the properties of ortho-positronium (o-Ps) annihilating in n-eicosane filler depend on the microcapsule morphology. In the samples where the whole interior is composed of n-eicosane and the polymer forms the outer shell only, the n-eicosane behaves like a neat macroscopic sample. In the microcapsules containing the network of polymer threads inside the globule, n-eicosane shows no rise of o-Ps intensity with time which is typical for all pure alkanes. For this morphology, the melting point of n-eicosane is preceded by the 4 K wide temperature range, where the structure resembling the rotator phase is observed (rotator phase appears in neat even-numbered alkanes with carbon chain over 20 atoms). Supplementary data were obtained by the DSC method. SEM images confirmed the morphological differentiation of microcapsules. Low temperature (close to liquid nitrogen) destroys the structure of microcapsules, particularly their outer shell. - Highlights: • Polymer-alkane microcapsules were synthesized with different morphology. • Morphological diversity of microcapsules is reflected in the parameters of the PALS. • PALS show the effect of spatial limitations on the formation of lamellar structure. • PALS is a new way to determine the percentage of microcapsules components.

  13. Effectiveness of ProTaper Universal retreatment instruments used with rotary or reciprocating adaptive motion in the removal of root canal filling material.

    Science.gov (United States)

    Capar, I D; Arslan, H; Ertas, H; Gök, T; Saygılı, G

    2015-01-01

    To compare the effectiveness of ProTaper Universal retreatment instruments with continuous rotation and adaptive motion (AM; a modified reciprocating motion that combines rotational and reciprocating motion) in the removal of filling material. Mesiobuccal root canals in 36 mandibular first molars were instrumented up to size F2 with the ProTaper Universal instrument (Dentsply Maillefer, Ballaigues, Switzerland) and filled using sealer and ProTaper Universal F2 gutta-percha cones. Gutta-percha was then down-packed and the root canal backfilled using the extruder hand-piece of the Elements Obturation System (SybronEndo, Orange, CA, USA). The teeth were assigned to two groups (n = 18), and removal of the root fillings was performed using one of the following techniques: group 1) ProTaper Universal retreatment files used with rotational motion (RM) and group 2) ProTaper Universal retreatment files used with adaptive motion (AM) (600° clockwise/0° counter-clockwise to 370° clockwise/50° counter-clockwise). The teeth were sectioned, and both halves were analysed at 8 × magnification. The percentage of remaining filling material was recorded. The data were analysed statistically using the Student's t-test at a 95% confidence level (P ProTaper Universal retreatment files with adaptive motion removed more filling materials from root canals than the rotational movement. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  14. Diffusion and Leaching Behavior of Radionuclides in Category 3 Waste Encasement Concrete and Soil Fill Material – Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Mattigod, Shas V.; Wellman, Dawn M.; Bovaird, Chase C.; Parker, Kent E.; Clayton, Libby N.; Powers, Laura; Recknagle, Kurtis P.; Wood, Marcus I.

    2011-08-31

    One of the methods being considered for safely disposing of Category 3 low-level radioactive wastes is to encase the waste in concrete. Such concrete encasement would contain and isolate the waste packages from the hydrologic environment and would act as an intrusion barrier. The current plan for waste isolation consists of stacking low-level waste packages on a trench floor, surrounding the stacks with reinforced steel, and encasing these packages in concrete. These concrete-encased waste stacks are expected to vary in size with maximum dimensions of 6.4 m long, 2.7 m wide, and 4 m high. The waste stacks are expected to have a surrounding minimum thickness of 15 cm of concrete encasement. These concrete-encased waste packages are expected to withstand environmental exposure (solar radiation, temperature variations, and precipitation) until an interim soil cover or permanent closure cover is installed, and to remain largely intact thereafter. Any failure of concrete encasement may result in water intrusion and consequent mobilization of radionuclides from the waste packages. The mobilized radionuclides may escape from the encased concrete by mass flow and/or diffusion and move into the surrounding subsurface environment. Therefore, it is necessary to assess the performance of the concrete encasement structure and the ability of the surrounding soil to retard radionuclide migration. The retardation factors for radionuclides contained in the waste packages can be determined from measurements of diffusion coefficients for these contaminants through concrete and fill material. Some of the mobilization scenarios include (1) potential leaching of waste form before permanent closure cover is installed; (2) after the cover installation, long-term diffusion of radionuclides from concrete waste form into surrounding fill material; (3) diffusion of radionuclides from contaminated soils into adjoining concrete encasement and clean fill material. Additionally, the rate of

  15. Numerical Calculation of Light Metal Filling Material PELE%轻金属填充材料 PELE 的数值仿真研究

    Institute of Scientific and Technical Information of China (English)

    李干; 王志军; 李运禄; 魏波

    2016-01-01

    In order to analyze the influence of the light metal filling material on the Penetrator with Enhanced Lateral Efficiency (PELE),AUTODYN explicit nonlinear dynamic analysis software was used to simulate the penetration of PELE filled with different light metal materials against target plate,and the damage effects of different projectile on target plates were obtained.The simulation results shows that the lower hardness of filling material is,the short the length of residual jacket is.Mg-Li alloy is suitable for filling material of PELE.%为了研究铝镁等轻金属作为弹芯对横向效应增强型侵彻体(PELE)的影响,采用显式非线性动力分析软件 AU-TODYN 对内装不同轻金属材料弹丸进行侵彻靶板数值模拟,获得了不同弹体对靶板的毁伤效应。结果表明:填充材料硬度越低,PELE 壳体残留越少,锂镁合金适宜作为 PELE 的填充材料。

  16. 33 CFR 338.2 - Activities involving the discharge of dredged or fill material into waters of the U.S.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Activities involving the discharge of dredged or fill material into waters of the U.S. 338.2 Section 338.2 Navigation and Navigable Waters CORPS OF ENGINEERS, DEPARTMENT OF THE ARMY, DEPARTMENT OF DEFENSE OTHER CORPS ACTIVITIES INVOLVING...

  17. The impacts of dental filling materials on RapidArc treatment planning and dose delivery: Challenges and solution

    Energy Technology Data Exchange (ETDEWEB)

    Mail, Noor; Al-Ghamdi, S.; Saoudi, A. [Princess Norah Oncology Center, National Guard Health Affairs, Jeddah 21423, Saudi Arabia and King Abdullah International Medical Research Center, Jeddah 21423 (Saudi Arabia); Albarakati, Y.; Ahmad Khan, M.; Saeedi, F.; Safadi, N. [Princess Norah Oncology Center, National Guard Health Affairs, Jeddah 21423 (Saudi Arabia)

    2013-08-15

    Purpose: The presence of high-density material in the oral cavity creates dose perturbation in both downstream and upstream directions at the surfaces of dental filling materials (DFM). In this study, the authors have investigated the effect of DFM on head and neck RapidArc treatment plans and delivery. Solutions are proposed to address (1) the issue of downstream dose perturbation, which might cause target under dosage, and (2) to reduce the upstream dose from DFM which may be the primary source of mucositis. In addition, an investigation of the clinical role of a custom-made plastic dental mold/gutter (PDM) in sparing the oral mucosa and tongue reaction is outlined.Methods: The influence of the dental filling artifacts on dose distribution was investigated using a geometrically well-defined head and neck intensity modulated radiation therapy (IMRT) verification phantom (PTW, Freiberg, Germany) with DFM inserts called amalgam, which contained 50% mercury, 25% silver, 14% tin, 8% copper, and 3% other trace metals. Three RapidArc plans were generated in the Varian Eclipse System to treat the oral cavity using the same computer tomography (CT) dataset, including (1) a raw CT image, (2) a streaking artifacts region, which was replaced with a mask of 10 HU, and (3) a 2 cm-thick 6000 HU virtual filter [a volume created in treatment planning system to compensate for beam attenuation, where the thickness of this virtual filter is based on the measured percent depth dose (PDD) data and Eclipse calculation]. The dose delivery for the three plans was verified using Gafchromic-EBT2 film measurements. The custom-made PDM technique to reduce backscatter dose was clinically tested on four head and neck cancer patients (T3, N1, M0) with DFM, two patients with PDM and the other two patients without PDM. The thickness calculation of the PDM toward the mucosa and tongue was purely based on the measured upstream dose. Patients’ with oral mucosal reaction was clinically examined

  18. The impacts of dental filling materials on RapidArc treatment planning and dose delivery: Challenges and solution

    International Nuclear Information System (INIS)

    Mail, Noor; Al-Ghamdi, S.; Saoudi, A.; Albarakati, Y.; Ahmad Khan, M.; Saeedi, F.; Safadi, N.

    2013-01-01

    Purpose: The presence of high-density material in the oral cavity creates dose perturbation in both downstream and upstream directions at the surfaces of dental filling materials (DFM). In this study, the authors have investigated the effect of DFM on head and neck RapidArc treatment plans and delivery. Solutions are proposed to address (1) the issue of downstream dose perturbation, which might cause target under dosage, and (2) to reduce the upstream dose from DFM which may be the primary source of mucositis. In addition, an investigation of the clinical role of a custom-made plastic dental mold/gutter (PDM) in sparing the oral mucosa and tongue reaction is outlined.Methods: The influence of the dental filling artifacts on dose distribution was investigated using a geometrically well-defined head and neck intensity modulated radiation therapy (IMRT) verification phantom (PTW, Freiberg, Germany) with DFM inserts called amalgam, which contained 50% mercury, 25% silver, 14% tin, 8% copper, and 3% other trace metals. Three RapidArc plans were generated in the Varian Eclipse System to treat the oral cavity using the same computer tomography (CT) dataset, including (1) a raw CT image, (2) a streaking artifacts region, which was replaced with a mask of 10 HU, and (3) a 2 cm-thick 6000 HU virtual filter [a volume created in treatment planning system to compensate for beam attenuation, where the thickness of this virtual filter is based on the measured percent depth dose (PDD) data and Eclipse calculation]. The dose delivery for the three plans was verified using Gafchromic-EBT2 film measurements. The custom-made PDM technique to reduce backscatter dose was clinically tested on four head and neck cancer patients (T3, N1, M0) with DFM, two patients with PDM and the other two patients without PDM. The thickness calculation of the PDM toward the mucosa and tongue was purely based on the measured upstream dose. Patients’ with oral mucosal reaction was clinically examined

  19. High-etch-rate bottom-antireflective coating and gap-fill materials using dextrin derivatives in via first dual-Damascene lithography process

    Science.gov (United States)

    Takei, Satoshi; Sakaida, Yasushi; Shinjo, Tetsuya; Hashimoto, Keisuke; Nakajima, Yasuyuki

    2008-03-01

    The present paper describes a novel class of bottom antireflective coating (BARC) and gap fill materials using dextrin derivatives. The general trend of interconnect fabrication for such a high performance LSI is to apply cupper (Cu)/ low-dielectric-constant (low-k) interconnect to reduce RC delay. A via-first dual damascene process is one of the most promising processes to fabricate Cu/ low-k interconnect due to its wide miss-alignment margin. The sacrificial materials containing dextrin derivatives under resist for lithography were developed in via-first dual damascene process. The dextrin derivatives in this study was obtained by the esterification of the hydroxyl groups of dextrin resulting in improved solubility in the resist solvents such as propylene glycol monomethylether, propylene glycol monomethylether acetate, and ethyl lactate due to avoid the issue of defects that were caused by incompatability. The etch rate of our developed BARC and gap fill materials using dextrin derivatives was more than two times faster than one of the ArF resists evaluated in a CF4 gas condition using reactive ion etching. The improved etch performance was also verified by comparison with poly(hydroxystyrene), acrylate-type materials and latest low-k materials as a reference. In addition to superior etch performance, these materials showed good resist profiles and via filling performance without voids in via holes.

  20. Cuspal deflection and microleakage in premolar teeth restored with bulk-fill flowable resin-based composite base materials.

    Science.gov (United States)

    Moorthy, A; Hogg, C H; Dowling, A H; Grufferty, B F; Benetti, A R; Fleming, G J P

    2012-06-01

    To assess the cuspal deflection and cervical microleakage of standardised Class II cavities incrementally filled with a dimethacrylate RBC or bulk-fill flowable RBC bases. Twenty-four sound upper premolar teeth with Class II cavities were allocated to three groups (n=8). Restoration of the teeth involved the placement of an RBC (GrandioSO) in eight oblique increments (Group A) or Groups B and C were restored to within 2 mm of the palatal cusp in a single increment with bulk-fill flowable RBC bases (SDR and x-tra base) before the two occlusal cavity increments were placed with GrandioSO. Buccal and palatal cusp deflections were recorded postirradiation using a twin channel deflection measuring gauge. Following restoration, the teeth were thermocycled, immersed in 0.2% basic fuchsin dye for 24h, sectioned and examined for cervical microleakage. The mean total cuspal deflection for the oblique incremental restoration technique was 11.26 (2.56) μm (Group A) and 4.63 (1.19) μm (Group B) and 4.73 (0.99) μm (Group C) for the bulk-fill flowable RBC bases. A significant increase in the mean total cuspal deflection for the incrementally filled GrandioSO compared with the SDR (P=0.007) and x-tra base (P=0.005) restored teeth was evident. No significant difference in the cervical microleakage scores was recorded between groups AC (P>0.05). The bulk-fill flowable RBC bases significantly reduced cuspal deflection compared with a conventional RBC restored in an oblique incremental filling technique with no associated change in cervical microleakage recorded. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Filled skutterudite antimonides: Validation of the electron-crystal phonon-glass approach to new thermoelectric materials

    Energy Technology Data Exchange (ETDEWEB)

    Mandrus, D; Sales, B C; Keppens, V [and others

    1997-07-01

    After a brief review of the transport and thermoelectric properties of filled skutterudite antimonides, the authors present resonant ultrasound, specific heat, and inelastic neutron scattering results that establish the existence of two low-energy vibrational modes in the filled skutterudite LaFe{sub 3}CoSb{sub 12}. It is likely that at least one of these modes represents the localized, incoherent vibrations of the La ion in an oversized atomic cage. These results support the usefulness of weakly bound, rattling ions for the improvement of thermoelectric performance.

  2. Effects of filling material and laser power on the formation of intermetallic compounds during laser-assisted friction stir butt welding of steel and aluminum alloys

    Science.gov (United States)

    Fei, Xinjiang; Jin, Xiangzhong; Peng, Nanxiang; Ye, Ying; Wu, Sigen; Dai, Houfu

    2016-11-01

    In this paper, two kinds of materials, Ni and Zn, are selected as filling material during laser-assisted friction stir butt welding of Q235 steel and 6061-T6 aluminum alloy, and their influences on the formation of intermetallic compounds on the steel/aluminum interface of the joints were first studied. SEM was used to analyze the profile of the intermetallic compound layer and the fractography of tensile fracture surfaces. In addition, EDS was applied to investigate the types of the intermetallic compounds. The results indicate that a thin iron-abundant intermetallic compound layer forms and ductile fracture mode occurs when Ni is added, but a thick aluminum-abundant intermetallic compound layer generates and brittle fracture mode occurs when Zn is added. So the tensile strength of the welds with Ni as filling material is greater than that with Zn as filling material. Besides, the effect of laser power on the formation of intermetallic compound layer when Ni is added was investigated. The preheated temperature field produced by laser beam in the cross section of workpiece was calculated, and the tensile strength of the joints at different laser powers was tested. Results show that only when suitable laser power is adopted, can suitable preheating temperature of the steel reach, then can thin intermetallic compound layer form and high tensile strength of the joints reach. Either excessive or insufficient laser power will reduce the tensile strength of the joints.

  3. 装填材料对PELE侵彻混凝土效能影响研究%Influence of filling material on penetration of PELE into concrete target

    Institute of Scientific and Technical Information of China (English)

    范少博; 陈智刚; 郭光全; 侯秀成; 陈冬梅

    2012-01-01

    为研究惰性装填物对PELE侵彻混凝土靶板效能影响,利用有限元软件LS-DYNA对不同惰性装填物的PELE侵彻混凝土靶板进行数值模拟.结果表明:与PELE侵彻混凝土靶板相比钢靶的形成破片质量较大、速度较慢;不同装填物对靶板的破坏效能不同;尼龙装填物比橡胶对靶板破坏的面积大,破片数量多.通过实验验证了模拟结果的正确性和可靠性.%Researches on the influence of inert fillings on penetration of PELE into concrete targets were carried out Penetration of PELE with different inert fillings into concrete targets was simulated by LS-DYNA. The results show that the fragments formed by penetration into concrete targets are larger and the velocity is lower than those into steel targets, and the different fillings have different damage efficiency. The damage area and the amount of fragments are larger for nylon filling material than for rubber. Correctness and reliability of the simulation results are verified by experiments.

  4. New Portland cement-based materials for endodontics mixed with articaine solution: a study of cellular response.

    Science.gov (United States)

    Gandolfi, Maria Giovanna; Perut, Francesca; Ciapetti, Gabriela; Mongiorgi, Romano; Prati, Carlo

    2008-01-01

    The biocompatibility of innovative tetrasilicate cements proposed for root-end filling restorations was tested. White ProRoot-MTA and AH Plus were used as control. The new cements were mixed with a local anesthetic solution (4% articaine) to form a paste. Human osteoblast-like cells Saos-2 were challenged in short-term cultures (72 hours) with solid materials and with material extracts prepared in culture medium. Cell growth and viability, cellular attachment, and morphologic features were assessed to verify cell/material interactions. No acute toxicity was exerted by the experimental cements in the assay systems. On solid samples Saos-2 adhered and proliferated on all the experimental cements and on MTA. The ultrastructural findings revealed that Saos-2 were able to adhere and to spread. The maintenance of the osteoblastic phenotype on the innovative cements was confirmed by the alkaline phosphatase assay. All experimental cements prepared with articaine supported the growth of bone-like cells, showing suitable properties to be used as canal sealers and root-end filling materials.

  5. The influence of irradiation potential on the degree of conversion and mechanical properties of two bulk-fill flowable RBC base materials.

    Science.gov (United States)

    Finan, Leah; Palin, William M; Moskwa, Natalia; McGinley, Emma Louise; Fleming, Garry J P

    2013-08-01

    To assess the depth of cure claims of two bulk-fill flowable RBC bases (SDR and x-tra base) using Fourier transform infrared (FTIR) spectroscopy, biaxial flexure strength (BFS), and Vickers hardness number (VHN) for specimen depths of 8mm (in 1mm increments). The degree of conversion (DC) was measured by monitoring the peak height (6164cm(-1)) of specimens (11.0±0.1mm diameter, 1.0±0.1mm thickness) during light irradiation for 20s using a quartz tungsten halogen light curing unit at 650±26mW/cm(2). DC was measured up to 120s post irradiation and repeated (n=3) for irradiation depths up to 8mm (in 1mm increments). Further series (n=20) of eight discs were prepared, stacked, light irradiated and numbered from one to eight (distance from the LCU). The specimens were stored at 37±1°C for 24h and BFS tested with the fracture fragments used to determine the VHN for each specimen. X-tra base can be irradiated to 8mm without a change in DC, something the SDR material cannot claim. However, the DC results confirm both bulk-fill flowable RBC bases have a depth of cure in excess of 4mm. One-way ANOVAs of BFS and VHN data showed significant differences between irradiation depths for x-tra base and SDR with increasing irradiation depth (4mm) resulting in significant reductions in mean BFS and VHN. The claims that the bulk-fill flowable RBC bases have a depth of cure in excess of 4mm can be confirmed but the differing chemistry of the resin formulations and filler characteristics contribute to significant differences in DC, BFS and VHN data between the two materials tested. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  6. Study of the pore filling fraction of carbazole-based hole-transporting materials in solid-state dye-sensitized solar cells

    Directory of Open Access Journals (Sweden)

    Marwa Ben Manaa

    2016-07-01

    Full Text Available Carbazole-based molecular glasses have emerged as a promising alternative to the widely used hole-transporting materials (HTM spiro-OMeTAD in solid-state dye-sensitized solar cells (DSSCs. The pore filling fraction (PFF of the mesoporous TiO2 layer by the HTM appears as a key parameter determining the final efficiency of a DSSC. In this work, the pore-filling properties of a family of carbazole-based HTMs are investigated for the first time and the photovoltaic behavior of DSSC devices (fabricated using the D102 dye is discussed in light of the present findings. It is found that N-aryl substituted 3,6-bis(diphenylaminyl-carbazole derivatives exhibit relatively low PFF of ca. 60%. Methoxy groups on the diphenylamine moieties have little influence on the PFF, indicating that the strong enhancement in power conversion efficiency (PCE is not related to an improved filling of the pores by the HTM. N-alkylated HTMs lead to higher PFF, increasing with the alkyl chain length, up to 78%.

  7. Effectiveness of ProTaper, D-RaCe, and Mtwo retreatment files with and without supplementary instruments in the removal of root canal filling material.

    Science.gov (United States)

    Marques da Silva, B; Baratto-Filho, F; Leonardi, D P; Henrique Borges, A; Volpato, L; Branco Barletta, F

    2012-10-01

    To assess the efficacy of different retreatment rotary files in removing gutta-percha and endodontic sealer from canals. Ninety straight single-rooted premolars were prepared up to a size 30 and filled with gutta-percha and sealer and then randomly assigned to six retreatment groups (n = 15). Groups I, III, and V were retreated using rotary systems ProTaper Universal Retreatment (PTUR), D-RaCe, and Mtwo Retreatment, respectively. Groups II, IV, and VI were retreated using the additional instruments F4, size 40, .04 taper RaCe, and size 40, .04 taper Mtwo, respectively. The roots were split vertically, and images of the halves were obtained using a high-resolution scanner and evaluated with AutoCAD software to calculate the percentage of residual material. Data were analyzed with Kruskal-Wallis and Student-Newman-Keuls tests using a 5% significance cutoff (P 0.05) between groups when additional instruments were used. The percentage of residual material was lowest in the PTUR group and was statistically significant only when compared to the D-RaCe system (P = 0.0038). All root canals had residual filling material after retreatment even when additional instruments were used. © 2012 International Endodontic Journal.

  8. Wear studies on ZrO2-filled PEEK as coating bearing materials for artificial cervical discs of Ti6Al4V

    International Nuclear Information System (INIS)

    Song, Jian; Liu, Yuhong; Liao, Zhenhua; Wang, Song; Tyagi, Rajnesh; Liu, Weiqiang

    2016-01-01

    Polyetheretherketone (PEEK) and its composite coatings are believed to be the potential candidates' bio-implant materials. However, these coatings have not yet been used on the surface of titanium-based orthopedics and joint products and very few investigations on the tribological characteristics could be found in the published literature till date. In this study, the wettabilities, composition and micro-hardness were characterized using contact angle measurement, scanning electron microscopy (SEM) and hardness tester. The tribological tests were conducted using a ball-on-disc contact pair under 25% newborn calf serum (NCS) lubricated condition. For comparison, bare Ti6Al4V was studied. The obtained results revealed that those PEEK/ZrO 2 composite coatings could improve the tribological properties of Ti6Al4V significantly. Adhesive wear and mild abrasive wear might be the dominant wear and failure mechanisms for PEEK/ZrO 2 composite coatings in NCS lubricated condition. After comprehensive evaluation in the present study, 5 wt.% ZrO 2 nanoparticles filled PEEK coating displayed the optimum tribological characteristics and could be taken as a potential candidate for the bearing material of artificial cervical disc. - Graphical abstract: Polyetheretherketone (PEEK) is a type of biomaterial which might be used in surface modification. In this study, the wettabilities, composition, hardness, friction and wear characteristics of PEEK/ZrO 2 coatings were investigated, compared with bare Ti6Al4V sample. After comprehensive evaluation, 5 wt.% ZrO 2 nanoparticles filled PEEK coating displayed the optimum tribological characteristics and could be taken as a potential candidate for the bearing material of artificial cervical disc. - Highlights: • PEEK coating were filled by ZrO 2 nanoparticles with different weight percentage. • The lubrication regime of all the tested samples are boundary lubrication. • Adhesive wear and mild abrasive wear were the dominant wear

  9. Wear studies on ZrO{sub 2}-filled PEEK as coating bearing materials for artificial cervical discs of Ti6Al4V

    Energy Technology Data Exchange (ETDEWEB)

    Song, Jian [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China); Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Liu, Yuhong, E-mail: liuyuhong@tsinghua.edu.cn [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China); Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Liao, Zhenhua; Wang, Song [Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057 (China); Tyagi, Rajnesh [Department of Mechanical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi 221005 (India); Liu, Weiqiang, E-mail: weiqliu@hotmail.com [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China); Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057 (China)

    2016-12-01

    Polyetheretherketone (PEEK) and its composite coatings are believed to be the potential candidates' bio-implant materials. However, these coatings have not yet been used on the surface of titanium-based orthopedics and joint products and very few investigations on the tribological characteristics could be found in the published literature till date. In this study, the wettabilities, composition and micro-hardness were characterized using contact angle measurement, scanning electron microscopy (SEM) and hardness tester. The tribological tests were conducted using a ball-on-disc contact pair under 25% newborn calf serum (NCS) lubricated condition. For comparison, bare Ti6Al4V was studied. The obtained results revealed that those PEEK/ZrO{sub 2} composite coatings could improve the tribological properties of Ti6Al4V significantly. Adhesive wear and mild abrasive wear might be the dominant wear and failure mechanisms for PEEK/ZrO{sub 2} composite coatings in NCS lubricated condition. After comprehensive evaluation in the present study, 5 wt.% ZrO{sub 2} nanoparticles filled PEEK coating displayed the optimum tribological characteristics and could be taken as a potential candidate for the bearing material of artificial cervical disc. - Graphical abstract: Polyetheretherketone (PEEK) is a type of biomaterial which might be used in surface modification. In this study, the wettabilities, composition, hardness, friction and wear characteristics of PEEK/ZrO{sub 2} coatings were investigated, compared with bare Ti6Al4V sample. After comprehensive evaluation, 5 wt.% ZrO{sub 2} nanoparticles filled PEEK coating displayed the optimum tribological characteristics and could be taken as a potential candidate for the bearing material of artificial cervical disc. - Highlights: • PEEK coating were filled by ZrO{sub 2} nanoparticles with different weight percentage. • The lubrication regime of all the tested samples are boundary lubrication. • Adhesive wear and mild abrasive

  10. Long-Term Strength of a Thick-Walled Pipe Filled with an Aggressive Medium, with Account for Damageability of the Pipe Material and Residual Strength

    Science.gov (United States)

    Piriev, S. A.

    2018-01-01

    This paper describes the study of scattered fracture of a thick-walled pipe filled with an aggressive medium, which creates uniform pressure on the inner surface of the pipe. It is assumed that the aggressive medium affects only the value of instantaneous strength. Damageability is described by an integral operator of the hereditary type. The problem is solved with allowance for residual strength of the pipe material behind the fracture front. Numerical calculation is carried out, and relationships between the fracture front coordinate and time for various concentrations of the aggressive medium and residual strength behind the fracture front are constructed.

  11. Bulk-Fill Resin Composites

    DEFF Research Database (Denmark)

    Benetti, Ana Raquel; Havndrup-Pedersen, Cæcilie; Honoré, Daniel

    2015-01-01

    the restorative procedure. The aim of this study, therefore, was to compare the depth of cure, polymerization contraction, and gap formation in bulk-fill resin composites with those of a conventional resin composite. To achieve this, the depth of cure was assessed in accordance with the International Organization...... for Standardization 4049 standard, and the polymerization contraction was determined using the bonded-disc method. The gap formation was measured at the dentin margin of Class II cavities. Five bulk-fill resin composites were investigated: two high-viscosity (Tetric EvoCeram Bulk Fill, SonicFill) and three low......-viscosity (x-tra base, Venus Bulk Fill, SDR) materials. Compared with the conventional resin composite, the high-viscosity bulk-fill materials exhibited only a small increase (but significant for Tetric EvoCeram Bulk Fill) in depth of cure and polymerization contraction, whereas the low-viscosity bulk...

  12. Possibilities of structure stabilisation in saliniferous formations using salt grit as a filling material; Moeglichkeiten der Gefuegestabilisierung von Salzgrusversatz

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Sebastian; Gruner, Matthias; Mischo, Helmut [TU Bergakademie Freiberg (Germany). Inst. fuer Bergbau und Spezialtiefbau

    2014-09-15

    The final disposal of high-active wastes in deep geological formations is an issue of great national and international import. On account of its good thermal conductivity and creep capability much research is currently focussed on sand as a host rock material. After the emplacement of wastes in abandoned mining cavities these must be sealed up to prevent fluids from coming into contact with the wastes. This must be done using materials that are either native or similar to the materials of the host formation. A particularly suitable material in the case of saliniferous formations is salt grit. Up to this point investigations have primarily been focused on preparing a suitable salt grit material and the rheological properties of the binding agent. This article presents and interprets the results of preliminary experiments on the miscibility of salt grit and binding agent suspensions. The MgO and CaSO{sub 4}-based binding agent systems analysed proved to be suitable. Among the MgO binding agents a composition of 3:1:8 was found to be more suitable than one of 5:1:8 on account of its lower initial viscosity. This reduces the amount of mixing required for wetting the material across all grain sizes, improving the chances of success. In the case of the two semihydrates of CaSO{sub 4} both the α and the β semihydrate proved suitable. This is due to a low fluid content which still also allows for a sufficiently low viscosity of the binding agent suspensions.

  13. Optical, magnetic, and dielectric properties of opal matrices with intersphere nanocavities filled with crystalline multiferroic, piezoelectric, and segnetoelectric materials

    Czech Academy of Sciences Publication Activity Database

    Samoilovich, M.I.; Rinkevich, A.B.; Bovtun, Viktor; Belyanin, A.F.; Kempa, Martin; Nuzhnyy, Dmitry; Tsvetkov, M.Yu.; Klescheva, S.M.

    2013-01-01

    Roč. 83, č. 11 (2013), s. 2132-2147 ISSN 1070-3632 R&D Projects: GA ČR GAP204/12/0232 Institutional support: RVO:68378271 Keywords : composites * opal matrices * optical, magnetic, and dielectric properties Subject RIV: JI - Composite Materials Impact factor: 0.418, year: 2013

  14. A multi-scale methodology to model damage, deformation and ignition of highly-filled energetic materials

    Energy Technology Data Exchange (ETDEWEB)

    Vivier, G. [Paris Univ., Paris (France). LMT Cachan; CEA Le Ripault, Monts (France); Trumel, H. [CEA Le Ripault, Monts (France); Hild, F. [Paris Univ., Paris (France). LMT Cachan

    2009-07-01

    The kinetic energy that occurs when energetic materials are impacted can be converted to heat through dissipative deformation processes while the macroscopic temperature remains unaffected. In this study, a thermodynamics-based approach was used to model the elasto-plastic behaviour that occurs during the deformation process of microstructures. Macroscopic material was modelled as a statistical distribution of unit cells containing a crack grain embedded in an elastic mortar-like matrix. A mesoscopic unit cell model was also developed under confined shear. The study demonstrated that stored energy is a non-negligible part of the total energy of the system, and that stored energy can be released during the unloading process. It was concluded that the mesoscopic analysis of the cracked cell demonstrates that continuum thermodynamics can be used to predict hot spots induced by friction. 7 refs., 7 figs.

  15. Bioaccessibility and Risk of Exposure to Metals and SVOCs in Artificial Turf Field Fill Materials and Fibers.

    Science.gov (United States)

    Pavilonis, Brian T; Weisel, Clifford P; Buckley, Brian; Lioy, Paul J

    2014-01-01

    To reduce maintenance costs, municipalities and schools are starting to replace natural grass fields with a new generation synthetic turf. Unlike Astro-Turf, which was first introduced in the 1960s, synthetic field turf provides more cushioning to athletes. Part of this cushioning comes from materials like crumb rubber infill, which is manufactured from recycled tires and may contain a variety of chemicals. The goal of this study was to evaluate potential exposures from playing on artificial turf fields and associated risks to trace metals, semi-volatile organic compounds (SVOCs), and polycyclic aromatic hydrocarbons (PAHs) by examining typical artificial turf fibers (n = 8), different types of infill (n = 8), and samples from actual fields (n = 7). Three artificial biofluids were prepared, which included: lung, sweat, and digestive fluids. Artificial biofluids were hypothesized to yield a more representative estimation of dose than the levels obtained from total extraction methods. PAHs were routinely below the limit of detection across all three biofluids, precluding completion of a meaningful risk assessment. No SVOCs were identified at quantifiable levels in any extracts based on a match of their mass spectrum to compounds that are regulated in soil. The metals were measurable but at concentrations for which human health risk was estimated to be low. The study demonstrated that for the products and fields we tested, exposure to infill and artificial turf was generally considered de minimus, with the possible exception of lead for some fields and materials. © 2013 Society for Risk Analysis.

  16. Bio-accessibility and Risk of Exposure to Metals and SVOCs in Artificial Turf Field Fill Materials and Fibers

    Science.gov (United States)

    Pavilonis, Brian T.; Weisel, Clifford P.; Buckley, Brian; Lioy, Paul J.

    2014-01-01

    To reduce maintenance costs, municipalities and schools are starting to replace natural grass fields with a new generation synthetic turf. Unlike Astro-Turf, which was first introduced in the 1960’s, synthetic field turf provides more cushioning to athletes. Part of this cushioning comes from materials like crumb rubber infill, which is manufactured from recycled tires and may contain a variety of chemicals. The goal of this study was to evaluate potential exposures from playing on artificial turf fields and associated risks to trace metals, semivolatile organic compounds (SVOCs), and polycyclic aromatic hydrocarbons (PAHs) by examining typical artificial turf fibers (n=8), different types of infill (n=8), and samples from actual fields (n=7). Three artificial biofluids were prepared which included: lung, sweat, and digestive fluids. Artificial biofluids were hypothesized to yield a more representative estimation of dose than the levels obtained from total extraction methods. PAHs were routinely below the limit of detection across all three biofluids precluding completion of a meaningful risk assessment. No SVOCs were identified at quantifiable levels in any extracts based on a match of their mass spectrum to compounds that are regulated in soil. The metals were measurable but at concentrations for which human health risk was estimated to be low. The study demonstrated that for the products and fields we tested, exposure to infill and artificial turf was generally considered de minimus, with the possible exception of lead for some fields and materials. PMID:23758133

  17. Additive Manufacturing of Metallic and Ceramic Components by the Material Extrusion of Highly-Filled Polymers: A Review and Future Perspectives

    Science.gov (United States)

    Cano, Santiago

    2018-01-01

    Additive manufacturing (AM) is the fabrication of real three-dimensional objects from metals, ceramics, or plastics by adding material, usually as layers. There are several variants of AM; among them material extrusion (ME) is one of the most versatile and widely used. In MEAM, molten or viscous materials are pushed through an orifice and are selectively deposited as strands to form stacked layers and subsequently a three-dimensional object. The commonly used materials for MEAM are thermoplastic polymers and particulate composites; however, recently innovative formulations of highly-filled polymers (HP) with metals or ceramics have also been made available. MEAM with HP is an indirect process, which uses sacrificial polymeric binders to shape metallic and ceramic components. After removing the binder, the powder particles are fused together in a conventional sintering step. In this review the different types of MEAM techniques and relevant industrial approaches for the fabrication of metallic and ceramic components are described. The composition of certain HP binder systems and powders are presented; the methods of compounding and filament making HP are explained; the stages of shaping, debinding, and sintering are discussed; and finally a comparison of the parts produced via MEAM-HP with those produced via other manufacturing techniques is presented. PMID:29783705

  18. Additive Manufacturing of Metallic and Ceramic Components by the Material Extrusion of Highly-Filled Polymers: A Review and Future Perspectives.

    Science.gov (United States)

    Gonzalez-Gutierrez, Joamin; Cano, Santiago; Schuschnigg, Stephan; Kukla, Christian; Sapkota, Janak; Holzer, Clemens

    2018-05-18

    Additive manufacturing (AM) is the fabrication of real three-dimensional objects from metals, ceramics, or plastics by adding material, usually as layers. There are several variants of AM; among them material extrusion (ME) is one of the most versatile and widely used. In MEAM, molten or viscous materials are pushed through an orifice and are selectively deposited as strands to form stacked layers and subsequently a three-dimensional object. The commonly used materials for MEAM are thermoplastic polymers and particulate composites; however, recently innovative formulations of highly-filled polymers (HP) with metals or ceramics have also been made available. MEAM with HP is an indirect process, which uses sacrificial polymeric binders to shape metallic and ceramic components. After removing the binder, the powder particles are fused together in a conventional sintering step. In this review the different types of MEAM techniques and relevant industrial approaches for the fabrication of metallic and ceramic components are described. The composition of certain HP binder systems and powders are presented; the methods of compounding and filament making HP are explained; the stages of shaping, debinding, and sintering are discussed; and finally a comparison of the parts produced via MEAM-HP with those produced via other manufacturing techniques is presented.

  19. Assessment of exposure to chemical agents in in fill material for artificial turf soccer pitches: development and implementation of a survey protocol

    International Nuclear Information System (INIS)

    Castellano, P.; Proietto, A.R.; Gordiani, A.; Ferrante, R.; Tranfo, G.; Paci, E.; Pigini, D.

    2008-01-01

    Health concerns over the composition of the in fill material used to construct artificial turf pitches (e.g., for soccer and rugby), raised the need to develop a specific procedure to assess the risks of human exposure to pollutants that may be released by these materials. The aim of this paper was to develop and implement a survey protocol to assess exposure of artificial turf pitches users (e.g., coaches and maintenance personnel) through environmental and biological monitoring of toxic and carcinogenic substances contained in some types of in fill materials for artificial turf pitches. The exposure was assessed by personal and environmental sampling of hazardous substances - particularly of benzene, toluene, xylene (BTX), polycyclic aromatic hydrocarbons (PAHs) and heavy metals (lead, cadmium, chromium, tin and zinc) - for comparison with the occupational exposure limit values as per the Italian regulations and the lists of the American Conference of Industrial Governmental Hygienists (ACGIH). In addition, biological monitoring was performed for the quantitative and qualitative determination of the exposure bio markers of the substances of interest in potentially exposed individuals and in control group. Environmental sampling was performed on an outdoor, artificial turf soccer pitch in a sports facility in Rome characterized by recycled in fill material (rubber granules from recycled tyres, without any further processing); suction pumps were used as environmental samplers to collect the samples (located in areas of the soccer pitch deemed representative of exposure conditions) and personal samplers (in this latter case exclusively for monitoring PAHs) worn by the coaches during training sessions. For the various substances the following sampling systems were used: vials for BTX (benzene, toluene, and xylene), filters for metals and combined systems (filter plus vial) for the PAHs. The extracts were then analyzed by various instrumental techniques such as gas

  20. An interview study of persons who attribute health problems to dental filling materials--part two in a triangulation study on 65 and 75 years old Swedes.

    Science.gov (United States)

    Ståhlnacke, Katri; Söderfeldt, Björn

    2013-01-01

    Dental materials are perceived as a health problem by some people, although scientists do not agree about possible causes of such problems. The aim of this paper was to gain a deeper knowledge and understanding of experiences from living with health problems attributed to dental materials. Addressed topics were the type of problem, both as to general and oral health, perceived causes of the problems,their experienced effect on life, and reception by health professionals. Persons, who in a previous large questionnaire study had answered that they had experienced troubles from dental materials and also agreed to answer follow-up questions, were contacted with a request to take part in an interview study. Eleven individual interviews were held.The interviews were transcribed verbatim and the material was analysed according to the Qualitative Content Analysis method. Meaning units were extracted and condensed into a number of codes, which were combined into subcategories, categories, and themes. Four themes were identified: 1) Long-term oral, mental, and somatic difficulties of varying character, caused by dental amalgam. 2) Problems treated mainly by replacement of dental material in fillings. 3) Powerful effects on life, mostly negative. 4) The reception by health professionals was generally good, but with elements of encounters where they felt treated with nonchalance and lack of respect. In conclusion, people who attributed their health difficulties to dental materials had a complex range of problems and the perception was that amalgam/mercury was the cause of the troubles. The reception from health professionals was perceived as generally good, although with occasional negative experiences.

  1. Combined effects of nonparaxiality, optical activity, and walk-off on rogue wave propagation in optical fibers filled with chiral materials

    Science.gov (United States)

    Temgoua, D. D. Estelle; Tchokonte, M. B. Tchoula; Kofane, T. C.

    2018-04-01

    The generalized nonparaxial nonlinear Schrödinger (NLS) equation in optical fibers filled with chiral materials is reduced to the higher-order integrable Hirota equation. Based on the modified Darboux transformation method, the nonparaxial chiral optical rogue waves are constructed from the scalar model with modulated coefficients. We show that the parameters of nonparaxiality, third-order dispersion, and differential gain or loss term are the main keys to control the amplitude, linear, and nonlinear effects in the model. Moreover, the influence of nonparaxiality, optical activity, and walk-off effect are also evidenced under the defocusing and focusing regimes of the vector nonparaxial NLS equations with constant and modulated coefficients. Through an algorithm scheme of wider applicability on nonparaxial beam propagation methods, the most influential effect and the simultaneous controllability of combined effects are underlined, showing their properties and their potential applications in optical fibers and in a variety of complex dynamical systems.

  2. Incidence of apical crack formation and propagation during removal of root canal filling materials with different engine driven nickel-titanium instruments

    Directory of Open Access Journals (Sweden)

    Taha Özyürek

    2017-11-01

    Full Text Available Objectives To determine the incidence of crack formation and propagation in apical root dentin after retreatment procedures performed using ProTaper Universal Retreatment (PTR, Mtwo-R, ProTaper Next (PTN, and Twisted File Adaptive (TFA systems. Materials and Methods The study consisted of 120 extracted mandibular premolars. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the negative control group. One hundred teeth were prepared, obturated, and then divided into 5 retreatment groups. The retreatment procedures were performed using the following files: PTR, Mtwo-R, PTN, TFA, and hand files. After filling material removal, apical enlargement was done using apical size 0.50 mm ProTaper Universal (PTU, Mtwo, PTN, TFA, and hand files. Digital images of the apical root surfaces were recorded before preparation, after preparation, after obturation, after filling removal, and after apical enlargement using a stereomicroscope. The images were then inspected for the presence of new apical cracks and crack propagation. Data were analyzed with χ2 tests using SPSS 21.0 software. Results New cracks and crack propagation occurred in all the experimental groups during the retreatment process. Nickel-titanium rotary file systems caused significantly more apical crack formation and propagation than the hand files. The PTU system caused significantly more apical cracks than the other groups after the apical enlargement stage. Conclusions This study showed that retreatment procedures and apical enlargement after the use of retreatment files can cause crack formation and propagation in apical dentin.

  3. Selection and specification criteria for fills for cut-and-fill mining

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, E. G.

    1980-05-15

    Because of significant differences in placement and loading conditions, the ideal fill material for a cut-and-fill operation has different characteristics to those for a fill for a filled open stoping operation. The differing requirements of the two mining operations must be understood and accounted for in establishing fill selection and specification criteria. Within the paper, aspects of the particular requirements of cut-and-fill mining are analyzed and related to the specific fill tests and properties required. Emphasis is placed upon the role of fill in ground support, though this cannot be isolated from overall fill performance. Where appropriate, test data are introduced and areas requiring continuing research highlighted.

  4. Incidence of apical crack formation and propagation during removal of root canal filling materials with different engine driven nickel-titanium instruments.

    Science.gov (United States)

    Özyürek, Taha; Tek, Vildan; Yılmaz, Koray; Uslu, Gülşah

    2017-11-01

    To determine the incidence of crack formation and propagation in apical root dentin after retreatment procedures performed using ProTaper Universal Retreatment (PTR), Mtwo-R, ProTaper Next (PTN), and Twisted File Adaptive (TFA) systems. The study consisted of 120 extracted mandibular premolars. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the negative control group. One hundred teeth were prepared, obturated, and then divided into 5 retreatment groups. The retreatment procedures were performed using the following files: PTR, Mtwo-R, PTN, TFA, and hand files. After filling material removal, apical enlargement was done using apical size 0.50 mm ProTaper Universal (PTU), Mtwo, PTN, TFA, and hand files. Digital images of the apical root surfaces were recorded before preparation, after preparation, after obturation, after filling removal, and after apical enlargement using a stereomicroscope. The images were then inspected for the presence of new apical cracks and crack propagation. Data were analyzed with χ 2 tests using SPSS 21.0 software. New cracks and crack propagation occurred in all the experimental groups during the retreatment process. Nickel-titanium rotary file systems caused significantly more apical crack formation and propagation than the hand files. The PTU system caused significantly more apical cracks than the other groups after the apical enlargement stage. This study showed that retreatment procedures and apical enlargement after the use of retreatment files can cause crack formation and propagation in apical dentin.

  5. Effect of Flapless Immediate Implantation and Filling the Buccal Gap with Xenograft Material on the Buccal Bone Level: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Mojgan Paknejad

    2017-12-01

    Full Text Available Objectives: Following tooth extraction, soft and hard tissue alterations occur; Different factors can affect this process. The objective of this study was to determine the effect of gap filling on buccal alveolar crestal bone level after immediate implant placement after 4- to 6-month observation period.Materials and Methods: This   randomized clinical trial was performed on 20 patients (mean age of 38.8 years requiring tooth extraction in a total of 27 areas in the anterior maxilla. The treatment strategy was as follows: atraumatic flapless tooth extraction, implant placement, insertion of a graft (test group or no material (control group between the implant and the socket wall, connection healing abutment placement and suturing the area. Clinical and cone beam computed tomographic examinations were performed before implant placement (baseline, 24 hours after surgery and 4-6 months (T2 after implant placement, to assess the buccal plate height (BH and implant complications.Results: After 4 months of healing, a reduction in different bone measurements was noticed in the two groups. No statistically significant differences were assessed in bone height measurements between the test and control groups at different time points. The study demonstrated that immediate implantation resulted in 1.30 and 1.66 mm reduction in buccal bone plate in the test and control groups, respectively.Conclusions: The study demonstrated that immediate implantation in the extraction socket together with xenograft failed to prevent bone resorption.

  6. Enhancement of open-circuit voltage and the fill factor in CdTe nanocrystal solar cells by using interface materials

    International Nuclear Information System (INIS)

    Zhu, Jiaoyan; Yang, Yuehua; Gao, Yuping; Qin, Donghuan; Wu, Hongbin; Huang, Wenbo; Hou, Lintao

    2014-01-01

    Interface states influence the operation of nanocrystal (NC) solar cell carrier transport, recombination and energetic mechanisms. In a typical CdTe NC solar cell with a normal structure of a ITO/p-CdTe NCs/n-acceptor (or without)/Al configuration, the contact between the ITO and CdTe is a non-ohm contact due to a different work function (for an ITO, the value is ∼4.7 eV, while for CdTe NCs, the value is ∼5.3 eV), which results in an energetic barrier at the ITO/CdTe interface and decreases the performance of the NC solar cells. This work investigates how interface materials (including Au, MoO x and C 60 ) affect the performance of NC solar cells. It is found that devices with interface materials have shown higher V oc than those without interface materials. For the case in which we used Au as an interface, we obtained a high open-circuit voltage of 0.65 V, coupled with a high fill factor (62%); this resulted in a higher energy conversion efficiency (ECE) of 5.3%, which showed a 30% increase in the ECE compared with those without the interlayer. The capacitance measurements indicate that the increased V oc in the case in which Au was used as the interface is likely due to good ohm contact between the Au’s and the CdTe NCs’ thin film, which decreases the energetic barrier at the ITO/CdTe interface. (paper)

  7. Efficacy of CM-Wire, M-Wire, and Nickel-Titanium Instruments for Removing Filling Material from Curved Root Canals: A Micro-Computed Tomography Study.

    Science.gov (United States)

    Rodrigues, Clarissa Teles; Duarte, Marco Antonio Hungaro; de Almeida, Marcela Milanezi; de Andrade, Flaviana Bombarda; Bernardineli, Norberti

    2016-11-01

    The aim of this ex vivo study was to evaluate the removal of filling material after using CM-wire, M-wire, and nickel-titanium instruments in both reciprocating and rotary motions in curved canals. Thirty maxillary lateral incisors were divided into 9 groups according to retreatment procedures: Reciproc R25 followed by Mtwo 40/.04 and ProDesign Logic 50/.01 files; ProDesign R 25/.06 followed by ProDesign Logic 40/.05 and ProDesign Logic 50/.01 files; and Gates-Glidden drills, Hedström files, and K-files up to apical size 30 followed by K-file 40 and K-file 50 up to the working length. Micro-computed tomography scans were performed before and after each reinstrumentation procedure to evaluate root canal filling removal. Statistical analysis was performed with Kruskal-Wallis, Friedman, and Wilcoxon tests (P < .05). No significant differences in filling material removal were found in the 3 groups of teeth. The use of Mtwo and ProDesign Logic 40/.05 rotary files did not enhance filling material removal after the use of reciprocating files. The use of ProDesign Logic 50/.01 files significantly reduced the amount of filling material at the apical levels compared with the use of reciprocating files. Association of reciprocating and rotary files was capable of removing a large amount of filling material in the retreatment of curved canals, irrespective of the type of alloy of the instruments. The use of a ProDesign Logic 50/.01 file for apical preparation significantly reduced the amount of remnant material in the apical portion when compared with reciprocating instruments. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  8. Mechanics of filled carbon nanotubes

    KAUST Repository

    Monteiro, A.O.; Cachim, P.B.; Da Costa, Pedro M. F. J.

    2014-01-01

    The benefits of filling carbon nanotubes (CNTs) with assorted molecular and crystalline substances have been investigated for the past two decades. Amongst the study of new structural phases, defects, chemical reactions and varied types of host-guest interactions, there is one fundamental characterisation aspect of these systems that continues to be overlooked: the mechanical behaviour of filled CNTs. In contrast to their empty counterparts, the mechanics of filled CNTs is a subject where reports appear far and apart, this despite being key to the application of these materials in technological devices. In the following paragraphs, we review the work that has been carried out up to the present on the mechanics of filled CNTs. The studies discussed range from experimental resonant frequency essays performed within electron microscopes to modelling, via molecular dynamics, of three-point bending of nanotubes filled with gases. (C) 2014 Elsevier B.V. All rights reserved.

  9. Mechanics of filled carbon nanotubes

    KAUST Repository

    Monteiro, A.O.

    2014-04-01

    The benefits of filling carbon nanotubes (CNTs) with assorted molecular and crystalline substances have been investigated for the past two decades. Amongst the study of new structural phases, defects, chemical reactions and varied types of host-guest interactions, there is one fundamental characterisation aspect of these systems that continues to be overlooked: the mechanical behaviour of filled CNTs. In contrast to their empty counterparts, the mechanics of filled CNTs is a subject where reports appear far and apart, this despite being key to the application of these materials in technological devices. In the following paragraphs, we review the work that has been carried out up to the present on the mechanics of filled CNTs. The studies discussed range from experimental resonant frequency essays performed within electron microscopes to modelling, via molecular dynamics, of three-point bending of nanotubes filled with gases. (C) 2014 Elsevier B.V. All rights reserved.

  10. Technology of hardening fills for mined spaces

    International Nuclear Information System (INIS)

    Simek, P.; Holas, M.; Chyla, A.; Pech, P.

    1985-01-01

    The technology is described of hardening fills for mined spaces of uranium deposits in North Bohemian chalk. A special equipment was developed for the controlled preparation of a hardening mixture. The composition of the fill is determined by the strength of the filled rock, expecially by the standard strength, i.e., the minimal strength of the filling under uniaxial pressure. The said parameter determines the consumption of binding materials and thereby the total costs of the filling. A description is presented of the filling technology, including rabbit tube transport of the mixture and quality control. (Pu)

  11. Fluoride release and recharge behavior of a nano-filled resin-modified glass ionomer compared with that of other fluoride releasing materials.

    Science.gov (United States)

    Mitra, Sumita B; Oxman, Joe D; Falsafi, Afshin; Ton, Tiffany T

    2011-12-01

    To compare the long-term fluoride release kinetics of a novel nano-filled two-paste resin-modified glass-ionomer (RMGI), Ketac Nano (KN) with that of two powder-liquid resin-modified glass-ionomers, Fuji II LC (FLC) and Vitremer (VT) and one conventional glass-ionomer, Fuji IX (FIX). Fluoride release was measured in vitro using ion-selective electrodes. Kinetic analysis was done using regression analysis and compared with existing models for GIs and compomers. In a separate experiment the samples of KN and two conventional glass-ionomers, FIX and Ketac Molar (KM) were subjected to a treatment with external fluoride source (Oral-B Neutra-Foam) after 3 months of fluoride release and the recharge behavior studied for an additional 7-day period. The cumulative amount of fluoride released from KN, VT and FLC and the release profiles were statistically similar but greater than that for FIX at P coating of KN with its primer and of DY with its adhesive did not significantly alter the fluoride release behavior of the respective materials. The overall rate for KN was significantly higher than for the compomer DY. DY showed a linear rate of release vs. t and no burst effect as expected for compomers. The nanoionomer KN showed fluoride recharge behavior similar to the conventional glass ionomers FIX and KM. Thus, it was concluded that the new RMGI KN exhibits fluoride ion release behavior similar to typical conventional and RMGIs and that the primer does not impede the release of fluoride.

  12. Study of 5f electron based filled skutterudite compound EuFe{sub 4}Sb{sub 12}, a thermoelectric (TE) material: FP-LAPW method

    Energy Technology Data Exchange (ETDEWEB)

    Shankar, A., E-mail: amitshan2009@gmail.com [Department of Physics, Mizoram University, Aizawl 796004 (India); Rai, D.P., E-mail: dibyaprakashrai@gmail.com [Beijing Computational Science Research Center, 3 Heqing Road, Beijing 100084 (China); Khenata, R. [Laboratoire de Physique Quantique et de Modlisation Mathmatique (LPQ3M), Dpartement de Technologie, Universit de Mascara, 29000 Mascara (Algeria); Maibam, J. [Department of Physics, Assam University, Silchar 788011 (India); Sandeep, E-mail: sndp.chettri@gmail.com [Department of Physics, Mizoram University, Aizawl 796004 (India); Thapa, R.K., E-mail: r.k.thapa@gmail.com [Department of Physics, Mizoram University, Aizawl 796004 (India)

    2015-01-15

    Highlights: • The compound EuFe{sub 4}Sb{sub 12} shows a semi-metallic behavior with pseudo gap. • The inherent dense band near E{sub F} facilitate the charge carriers. • The magnetic moment within LSDA and mBJ are underestimated. • The inclusion of onsite Coulomb repulsion (U) in LSDA has improved the result. • The results obtained from LSDA + U are consistent with the experimental data. - Abstract: We have studied the elastic, electronic and magnetic properties along with the thermoelectric properties of an undoped filled skutterudite EuFe{sub 4}Sb{sub 12} using full-potential linearized augmented plane wave (FP-LAPW) method. The LSDA, LSDA + U and a new exchange-correlation functional called modified Becke Johnson (mBJ) potential based on density functional theory (DFT) were used for studying material properties. The Eu-f and Fe-d are strongly correlated elements thus the inclusion of Coulomb repulsion (U) expected to give an exact ground state properties. The exchange-splitting of Eu-4f states were analyzed to explain the ferromagnetic behavior of EuFe{sub 4}Sb{sub 12} (half-metallic behavior). The numerical values of isotropic elastic parameters and related properties are estimated in the framework of the Voigt–Reuss–Hill approximation. The calculation of thermal transport properties at various temperature shows the high value of Seebeck coefficient and figure of merit (ZT) = 0.25 at room temperature in consistent to the experimental results.

  13. Evaluation of debris extruded apically during the removal of root canal filling material using ProTaper, D-RaCe, and R-Endo rotary nickel-titanium retreatment instruments and hand files.

    Science.gov (United States)

    Topçuoğlu, Hüseyin Sinan; Aktı, Ahmet; Tuncay, Öznur; Dinçer, Asiye Nur; Düzgün, Salih; Topçuoğlu, Gamze

    2014-12-01

    The aim of this study was to evaluate the amount of debris extruded apically during the removal of root canal filling material using ProTaper (Dentsply Maillefer, Ballaigues, Switzerland), D-RaCe (FKG Dentaire, La Chaux-de-Fonds, Switzerland), and R-Endo (Micro-Mega, Besançon, France) nickel-titanium (NiTi) rotary retreatment instruments and hand files. Sixty extracted single-rooted mandibular premolar teeth were prepared with K-files and filled with gutta-percha and AH Plus sealer (Dentsply DeTrey, Konstanz, Germany). The teeth were then randomly assigned to 4 groups (n = 15 for each group) for retreatment. The removal of canal filling material was performed as follows: hand files, ProTaper, D-RaCe, and R-Endo retreatment instruments. Debris extruded apically during the removal of canal filling material was collected into preweighed Eppendorf tubes. The tubes were then stored in an incubator at 70°C for 5 days. The weight of the dry extruded debris was established by subtracting the preretreatment and postretreatment weight of the Eppendorf tubes for each group. The data obtained were analyzed using 1-way analysis of variance and Tukey post hoc tests. All retreatment techniques caused the apical extrusion of debris. Hand files produced significantly more debris when compared with ProTaper, D-RaCe, and R-Endo rotary systems (P ProTaper, D-RaCe, and R-Endo retreatment systems (P > .05). The findings showed that during the removal of root canal filling material, rotary NiTi retreatment instruments used in this study caused less apical extrusion of debris compared with hand files. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  14. Hydrogen Filling Station

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, Robert F; Sabacky, Bruce; Anderson II, Everett B; Haberman, David; Al-Hassin, Mowafak; He, Xiaoming; Morriseau, Brian

    2010-02-24

    future. Project partners also conducted a workshop on hydrogen safety and permitting. This provided an opportunity for the various permitting agencies and end users to gather to share experiences and knowledge. As a result of this workshop, the permitting process for the hydrogen filling station on the Las Vegas Valley Water District’s land was done more efficiently and those who would be responsible for the operation were better educated on the safety and reliability of hydrogen production and storage. The lessons learned in permitting the filling station and conducting this workshop provided a basis for future hydrogen projects in the region. Continuing efforts to increase the working pressure of electrolysis and efficiency have been pursued. Research was also performed on improving the cost, efficiency and durability of Proton Exchange Membrane (PEM) hydrogen technology. Research elements focused upon PEM membranes, electrodes/catalysts, membrane-electrode assemblies, seals, bipolar plates, utilization of renewable power, reliability issues, scale, and advanced conversion topics. Additionally, direct solar-to-hydrogen conversion research to demonstrate stable and efficient photoelectrochemistry (PEC) hydrogen production systems based on a number of optional concepts was performed. Candidate PEC concepts included technical obstacles such as inefficient photocatalysis, inadequate photocurrent due to non-optimal material band gap energies, rapid electron-hole recombination, reduced hole mobility and diminished operational lifetimes of surface materials exposed to electrolytes. Project Objective 1: Design, build, operate hydrogen filling station Project Objective 2: Perform research and development for utilizing solar technologies on the hydrogen filling station and convert two utility vehicles for use by the station operators Project Objective 3: Increase capacity of hydrogen filling station; add additional vehicle; conduct safety workshop; develop a roadmap for

  15. QENS investigation of filled rubbers

    CERN Document Server

    Triolo, A; Desmedt, A; Pieper, J K; Lo Celso, F; Triolo, R; Negroni, F; Arrighi, V; Qian, H; Frick, B

    2002-01-01

    The polymer segmental dynamics is investigated in a series of silica-filled rubbers. The presence of inert fillers in polymers greatly affects the mechanical and physical performance of the final materials. For example, silica has been proposed as a reinforcing agent of elastomers in tire production. Results from quasielastic neutron scattering and Dynamic Mechanical Thermal Analysis (DMTA) measurements are presented on styrene-ran-butadiene rubber filled with silica. A clear indication is obtained of the existence of a bimodal dynamics, which can be rationalized in terms of the relaxation of bulk rubber and the much slower relaxation of the rubber adsorbed on the filler surface. (orig.)

  16. Sodium fill of FFTF

    International Nuclear Information System (INIS)

    Waldo, J.B.; Greenwell, R.K.; Keasling, T.A.; Collins, J.R.; Klos, D.B.

    1980-02-01

    With construction of the Fast Flux Test Facility (FFTF) completed, the first major objective in the startup program was to fill the sodium systems. A sodium fill sequence was developed to match construction completion, and as systems became available, they were inerted, preheated, and filled with sodium. The secondary sodium systems were filled first while dry refueling system testing was in progress in the reactor vessel. The reactor vessel and the primary loops were filled last. This paper describes the methods used and some of the key results achieved for this major FFTF objective

  17. 装填材料密度对侵彻膨胀弹终点效应的影响%Influence of Filling Material Density on Terminal Effect of PELE Projectile

    Institute of Scientific and Technical Information of China (English)

    尹建平; 王志军; 魏继允

    2011-01-01

    By building the model of the penetrator with enhanced lateral efficiency(PELE) and target of steel plate, LS-DYNA was used to simulate penetration of PELE filled copper, 2024-T3 aluminium and nylon against 4340 steel plate at the impact velocity of 1 500 m/s. The results show that the filling material has important influence on the producing of lateral efficiency. In a certain range, with the filling material density decreases, the lateral efficiency range becomes wider, and the remnant velocity after penetrating target becomes lesser.%在建立弹靶模型的基础上,采用有限元软件LS-DYNA分别对装填铜,2024-T3铝和尼龙的侵彻膨胀弹以1 500 m/s着靶速度侵彻4340钢靶板的过程进行了数值模拟.结果表明:装填材料对侵彻膨胀弹横向效应的产生有较大影响.一定范围内装填材料的密度越小,PELE速度变化缓慢,而且变化持续时间越长,穿透靶板后的残余速度越小,产生横向效应的区域越大.

  18. Elaboration of protocol for characterization of clay as a filling material and coverage for surface repository; Elaboracao de protocolo para caracterizacao de argilas como material de recheio e de cobertura para repositorio de superficie

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Daisy Mary Marchezini dos

    2017-04-01

    The nuclear energy in its various applications generates wastes that must be properly treated. The Radioactive Waste Management covers operations since generation of the waste until to its storage in repository ensuring the protection of man and of environment of the possible negative impacts. The radioactive waste are segregated, treated, conditioned in suitable packaging and posteriorly are stored or disposal in repository. The “RBMN Project” is a priority project of CNEN to implementation the repository for the deposition of low and intermediate level radioactive waste generated by nuclear energy activities in Brazil, proposing a definitive solution for its storage. Engineered and natural barriers as the filling layer and coverage layer will compose the disposal system of a near surface repository, concept proposed by the “RBMN Project”. The use these barriers views to avoid or restrict the release of radionuclides present in waste for the humans beings and environment. The waterproofing barriers are composed of clays. Certainly, for the national repository, will be used those clays existing in the place where it will be implanted it. So some fundamentals tests will have to be carried for to verify the suitability of these clays as barriers. These tests were determined and realized with a reference clay, a brazilian bentonite constituted of 67.2% montmorillonite. The results were compared with national and international literature of materials with similar mineralogical features. The values found with 95% reliance were 9.73±0,35 μm for granulometric size. For the moisture content were 13,3±0,6% and for capacity of cationic exchange were , 816±9 mmol.kg{sup -1}. For the hydraulic conductivity, without the use of internal pressure, it was obtained maximum value of 59.0% saturated. In addition, during the observed period, there was no percolation in the test specimen submitted to internal pressure of 200 kPa. This result leads to the conclusion that the

  19. Iron filled carbon nanostructures from different precursors

    International Nuclear Information System (INIS)

    Costa, S.; Borowiak-Palen, E.; Bachmatiuk, A.; Ruemmeli, M.H.; Gemming, T.; Kalenczuk, R.J.

    2008-01-01

    Here, we present a study on the synthesis of different nanostructures with one single-step in situ filling (encapsulation) via carbon vapor deposition (CVD). Ferrocene, acetylferrocene and iron (II) nitrate as iron precursors were explored. The application of each of these compounds resulted in different carbon nanomaterials such as: iron filled multiwalled carbon nanotubes with a low filling ratio (Fe-MWCNT), iron filled nanocapsules and unfilled MWCNT. The as-produced samples were purified by high temperature annealing and acid treatment. The purified materials were characterised using transmission electron microscopy (TEM) and Raman spectroscopy

  20. Computerized simulation of the mechanical behavior of wood-filled shock absorbers of radioactive materials transport casks; Rechnerische Simulation des mechanischen Verhaltens von holzgefuellten Stossdaempfern von Transportbehaeltern fuer radioaktive Stoffe

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, Martin; Wille, Frank [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany)

    2011-07-01

    In Germany the mechanical component inspection of transport containers for radioactive materials is performed by BAM (Bundesanstalt fuer Materialforschung und -pruefung) under consideration of national and international standards and guidelines. Experimental and calculative (analytical and numerical) techniques combined with material and/or component testing are the basis of assessment concepts according the state of the art. The authors describe the experiences of BAM concerning assessment and description of the mechanical behavior of shock absorbing components, including modeling strategies, material models, drop tests and experiment-calculation comparison. Energy absorbing components are used to reduce the impact forces at the container in case of a transport accident. In Germany wood filled thin-walled constructions are used. The deformation behavior of the wood is a main part of the calculative simulation procedures in comparison with experimental tests.

  1. Operation feedback of hydrogen filling station

    International Nuclear Information System (INIS)

    Pregassame, S.; Barral, K.; Allidieres, L.; Charbonneau, T.; Lacombe, Y.

    2004-01-01

    One of the technical challenges of hydrogen technology is the development of hydrogen infrastructures which satisfy either safety requirements and reliability of filling processes. AIR LIQUIDE realized an hydrogen filling station in Sassenage (France) operational since September 2003. This station is able to fill 3 buses a day up to 350bar by equilibrium with high pressure buffers. In parallel with commercial stations, the group wanted to create a testing ground in real conditions running with several objectives: validate on a full scale bench a simulation tool able to predict the temperature of both gas and cylinder's materials during filling processes; define the best filling procedures in order to reach mass, temperature and filling time targets; analyse the temperature distribution and evolution inside the cylinder; get a general knowledge about hydrogen stations from safety and reliability point of view; operate the first full scale refuelling station in France. The station is also up-graded for 700bar filling from either a liquid hydrogen source or a gas booster, with cold filling possibility. This paper presents the results concerning 350bar filling : thermal effects, optimal filling procedures and influence of parameters such as climatic conditions are discussed. (author)

  2. Effects of Ceramic Density and Sintering Temperature on the Mechanical Properties of a Novel Polymer-Infiltrated Ceramic-Network Zirconia Dental Restorative (Filling) Material.

    Science.gov (United States)

    Li, Weiyan; Sun, Jian

    2018-05-10

    BACKGROUND Polymer-infiltrated ceramic-network (PICN) dental material is a new and practical development in orthodontics. Sintering is the process of forming a stable solid mass from a powder by heating without melting. The aim of this study was to evaluate the effects of sintering temperature on the mechanical properties of a PICN zirconia dental material. MATERIAL AND METHODS A dense zirconia ceramic and four PICN zirconia dental materials, with varying porosities, were sintered at three different temperatures; 12 PICN zirconia dental materials based on these porous ceramics were prepared, as well as a pure polymer. After the specimen preparation, flexural strength and elastic modulus values were measured using the three-point bending test, and fracture toughness were determined by the single-edge notched beam (SENB) method. The Vickers hardness test method was used with an indentation strength (IS) test. Scanning electron microscopy (SEM) was used to examine the microstructure of the ceramic surface and the fracture surface. RESULTS Mechanical properties of the PICN dental materials, including flexural strength, elastic modulus, fracture toughness, and hardness, were more similar to the properties of natural teeth when compared with traditional dental ceramic materials, and were affected by the density and sintering temperature. SEM showed that the porous ceramic network became cohesive and that the length of cracks in the PICN dental material was reduced. CONCLUSIONS PICN zirconia dental materials were characterized by similar mechanical properties to natural dental tissues, but further studies are required continue to improve the similarities with natural human enamel and dentin.

  3. Filter to be tightly installed in a room as a partition and which can be filled with a contact material susceptible of being poured e.g. activated charcoal for cleaning especially radioactive air or gases in nuclear installations

    International Nuclear Information System (INIS)

    Neumann, G.M.

    1978-01-01

    The filter is designed in such manner that it will resist all loads - including earthquake - without loosing its operability. It consists of a box formed by stable corner irons filled with absorbing material and bounded on two sides by sieves through which the radioactive gases can flow in and out. The invention especially concerns the configuration of the perforations and the screwing of the casing elements to the frame as well as the arrangement in the concrete wall. Measures for fire fighting are also provided for. (UWI) [de

  4. New recycling approaches for thermoset polymeric composite wastes – an experimental study on polyester based concrete materials filled with fibre reinforced plastic recyclates

    OpenAIRE

    Ribeiro, M. C. S.; Fiúza, António; Meira Castro, A C; Dinis, M. L.; Silva, Francisco J. G.; Meixedo, João Paulo

    2011-01-01

    In this study, a new waste management solution for thermoset glass fibre reinforced polymer (GFRP) based products was assessed. Mechanical recycling approach, with reduction of GFRP waste to powdered and fibrous materials was applied, and the prospective added-value of obtained recyclates was experimentally investigated as raw material for polyester based mortars. Different GFRP waste admixed mortar formulations were analyzed varying the content, between 4% up to 12% in we...

  5. Filling a Conical Cavity

    Science.gov (United States)

    Nye, Kyle; Eslam-Panah, Azar

    2016-11-01

    Root canal treatment involves the removal of infected tissue inside the tooth's canal system and filling the space with a dense sealing agent to prevent further infection. A good root canal treatment happens when the canals are filled homogeneously and tightly down to the root apex. Such a tooth is able to provide valuable service for an entire lifetime. However, there are some examples of poorly performed root canals where the anterior and posterior routes are not filled completely. Small packets of air can be trapped in narrow access cavities when restoring with resin composites. Such teeth can cause trouble even after many years and lead the conditions like acute bone infection or abscesses. In this study, the filling of dead-end conical cavities with various liquids is reported. The first case studies included conical cavity models with different angles and lengths to visualize the filling process. In this investigation, the rate and completeness at which a variety of liquids fill the cavity were observed to find ideal conditions for the process. Then, a 3D printed model of the scaled representation of a molar with prepared post spaces was used to simulate the root canal treatment. The results of this study can be used to gain a better understanding of the restoration for endodontically treated teeth.

  6. Raman spectra of filled carbon nanotubes

    International Nuclear Information System (INIS)

    Bose, S.M.; Behera, S.N.; Sarangi, S.N.; Entel, P.

    2004-01-01

    The Raman spectra of a metallic carbon nanotube filled with atoms or molecules have been investigated theoretically. It is found that there will be a three way splitting of the main Raman lines due to the interaction of the nanotube phonon with the collective excitations (plasmons) of the conduction electrons of the nanotube as well as its coupling with the phonon of the filling material. The positions and relative strengths of these Raman peaks depend on the strength of the electron-phonon interaction, phonon frequency of the filling atom and the strength of interaction of the nanotube phonon and the phonon of the filling atoms. Careful experimental studies of the Raman spectra of filled nanotubes should show these three peaks. It is also shown that in a semiconducting nanotube the Raman line will split into two and should be observed experimentally

  7. Conductive materials for proton exchange membrane fuel cell bipolar plates made from PVDF, PET and co-continuous PVDF/PET filled with carbon additives

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, L.; Mighri, F.; Deyrail, Y. [CREPEC, Center for Applied Research on Polymers and Composites, QC (Canada); Department of Chemical Engineering, Laval University, QC (Canada); Elkoun, S. [CREPEC, Center for Applied Research on Polymers and Composites, QC (Canada); Department of Mechanical Engineering, Sherbrooke University, QC (Canada)

    2010-12-15

    The aim of this work was to develop and characterise electrically conductive materials for proton exchange membrane fuel cells and bipolar plates (BPPs). These BPPs were made from highly conductive blends of polyethylene terephthalate (PET) and polyvinylidene fluoride (PVDF), as matrix phase. The conductive materials were developed from carefully formulated blends composed of conductive carbon black (CB) powder and, in some cases, graphite synthetic flakes mixed with pure PET, PVDF or with PVDF/PET systems. They were first developed by twin-screw extrusion process then compression-molded to give BPP final shape. As the developed blends have to meet properties suitable for BPP applications, they were characterised for their rheological properties, electrical through-plane resistivity (the inverse of conductivity), oxygen permeability, flexural and impact properties. Results showed that lower resistivity was obtained with PVDF/CB blends due to the higher interfacial energy between the PVDF matrix and CB and also the higher density and crystallinity of PVDF, compared to those of PET. It was also observed that the lowest resistivity values were obtained with mixing PVDF and PET at controlled compositions to ensure PVDF/PET co-continuous morphology. Also, slow cooling rates helped to attain the lowest values of through-plane resistivity for all studied blends. This behaviour was related to the higher crystallinity obtained with low cooling rates leading to smaller amorphous regions in which carbon particles are much more concentrated. (Copyright copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  8. 21 CFR 872.3820 - Root canal filling resin.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Root canal filling resin. 872.3820 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3820 Root canal filling resin. (a) Identification. A root canal filling resin is a device composed of material, such as methylmethacrylate, intended...

  9. Creep of granulated loose-fill insulation

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    This report presents a proposal for a standardised method for creep tests and the necessary theoretical framework that can be used to describe creep of a granulated loose-fill material. Furthermore results from a round robin test are shown. The round robin test was carried out in collaboration...... with SP-Building Physics in Sweden and VTT Building Technology in Finland. For the round robin test a cellulosic fibre insulation material was used. The proposed standardised method for creep tests and theories are limited to cases when the granulated loose-fill material is exposed to a constant...

  10. Analysis of the heat transfer mechanisms during energy storage in a Phase Change Material filled vertical finned cylindrical unit for free cooling application

    International Nuclear Information System (INIS)

    Solomon, Gnanadurai Ravikumar; Velraj, Ramalingam

    2013-01-01

    Highlights: • Freezing behavior of a PCM, in a cylinder with annular longitudinal fins is presented. • Among various fin heights, 20 mm fin contribute maximum heat transfer enhancement. • Addition of fins plays a contradictory role during the sensible cooling of liquid PCM. • The fin effect along with external cooling, vary the sensible cooling rate of liquid PCM. • The surface convective resistance dominated over the conductive resistance of PCM. - Abstract: The heat transfer performance of the Phase Change Material (PCM) used in free cooling application is low due to poor thermal conductivity. The addition of fins to enhance the heat transfer during solidification process is commonly employed, to address this. However for application such as free cooling, where the driving temperature potential is very less, the present experimental study is intended to investigate the sensible and subcooling phenomena during the outward cylindrical solidification of the PCM stored on the annulus side, along with 8 longitudinal uniformly spaced copper fins of different heights. The performance of the fins during solidification is analyzed, and the best suitable height is arrived at. The addition of fins plays a contradicting role during the sensible cooling of the liquid PCM, due to the suppression of free convection. The external cooling conditions along with the effect of the fin, vary the sensible cooling rate of the liquid PCM, that influences the subcooling effect, and also drifts the temperature at which major phase change occurs. In addition, the effects due to the inlet velocity of the heat transfer fluid, and its temperature on heat transfer are investigated and reported. The increase in velocity decreases the duration of solidification, and this effect is more pronounced towards the entry region, due to the higher local convective heat transfer co-efficient and a comparatively higher driving temperature potential

  11. Relleno de cavidades óseas en cirugía maxilofacial con materiales aloplásticos Bone cavity filling with alloplastic material in maxillofacial surgery

    Directory of Open Access Journals (Sweden)

    S. Ochandiano Caicoya

    2007-02-01

    Full Text Available En los estudios de regeneración ósea se distinguen dos tipos de defectos, los que carecen de capacidad de regeneración espontánea durante toda la vida del individuo (defectos de tamaño crítico y los que sí que poseen dicha capacidad (de tamaño no crítico, siempre que aportemos las condiciones adecuadas, estabilización del coágulo, mantenimiento del espacio y reposo mecánico (concepto de regeneración ósea guiada. En esta controversia revisamos el defecto óseo del seno maxilar y las cavidades residuales postquistectomía, ambos defectos de tamaño no crítico que conservan varias de sus paredes. En la elevación de seno muchos autores concluían que era necesario aportar siempre hueso autólogo en el material de injerto, bien en solitario o en distintas mezclas con biomateriales en proporciones no definidas, 50:50, 20:80 etc. La evidencia clínica y la que recoge la literatura en los últimos años contradice esa conclusión y ya se afirma que los biomateriales en exclusiva en el seno maxilar consiguen resultados equiparables al hueso autólogo siempre que se aumente el periodo de osificación. Repasamos nuevos estudios que incluso discuten la necesidad de utilizar ningún tipo de injerto para conseguir neoformación ósea dentro del seno maxilar. Los resultados en el defecto óseo de cavidades residuales postquistectomía, en las que consigamos mantener varias de sus paredes, son todavía más concluyentes. El mejor tratamiento de esos defectos es el cierre directo de la mucosa y esperar a la regeneración espontánea del defecto. La utilización de hueso autólogo es innecesaria y si aportamos biomateriales tampoco conseguimos un mejor comportamiento biomecánico del hueso residual, retrasamos la osificación y aumentamos el número de complicaciones. Sólo los defectos de espesor total pueden beneficiarse de la utilización de membranas. Los defectos que han perdido varias paredes pueden perder su capacidad de regeneración

  12. Tension-filled Governance?

    DEFF Research Database (Denmark)

    Celik, Tim Holst

    on the statesituated tension-filled functional relationship between legitimation and accumulation, the study both historically and theoretically reworks this approach and reapplies it for the post-1970s/1990s governance period. It asks whether and to what extent governance has served as a distinctive post- 1970s/1990s...

  13. filled neutron detectors

    Indian Academy of Sciences (India)

    Boron trifluoride (BF3) proportional counters are used as detectors for thermal neutrons. They are characterized by high neutron sensitivity and good gamma discriminating properties. Most practical BF3 counters are filled with pure boron trifluoride gas enriched up to 96% 10B. But BF3 is not an ideal proportional counter ...

  14. Gas filled detectors

    International Nuclear Information System (INIS)

    Stephan, C.

    1993-01-01

    The main types of gas filled nuclear detectors: ionization chambers, proportional counters, parallel-plate avalanche counters (PPAC) and microstrip detectors are described. New devices are shown. A description of the processes involved in such detectors is also given. (K.A.) 123 refs.; 25 figs.; 3 tabs

  15. Bio-inspired dental fillings

    Science.gov (United States)

    Deyhle, Hans; Bunk, Oliver; Buser, Stefan; Krastl, Gabriel; Zitzmann, Nicola U.; Ilgenstein, Bernd; Beckmann, Felix; Pfeiffer, Franz; Weiger, Roland; Müller, Bert

    2009-08-01

    Human teeth are anisotropic composites. Dentin as the core material of the tooth consists of nanometer-sized calcium phosphate crystallites embedded in collagen fiber networks. It shows its anisotropy on the micrometer scale by its well-oriented microtubules. The detailed three-dimensional nanostructure of the hard tissues namely dentin and enamel, however, is not understood, although numerous studies on the anisotropic mechanical properties have been performed and evaluated to explain the tooth function including the enamel-dentin junction acting as effective crack barrier. Small angle X-ray scattering (SAXS) with a spatial resolution in the 10 μm range allows determining the size and orientation of the constituents on the nanometer scale with reasonable precision. So far, only some dental materials, i.e. the fiber reinforced posts exhibit anisotropic properties related to the micrometer-size glass fibers. Dental fillings, composed of nanostructures oriented similar to the natural hard tissues of teeth, however, do not exist at all. The current X-ray-based investigations of extracted human teeth provide evidence for oriented micro- and nanostructures in dentin and enamel. These fundamental quantitative findings result in profound knowledge to develop biologically inspired dental fillings with superior resistance to thermal and mechanical shocks.

  16. Systolic ventricular filling.

    Science.gov (United States)

    Torrent-Guasp, Francisco; Kocica, Mladen J; Corno, Antonio; Komeda, Masashi; Cox, James; Flotats, A; Ballester-Rodes, Manel; Carreras-Costa, Francesc

    2004-03-01

    The evidence of the ventricular myocardial band (VMB) has revealed unavoidable coherence and mutual coupling of form and function in the ventricular myocardium, making it possible to understand the principles governing electrical, mechanical and energetical events within the human heart. From the earliest Erasistratus' observations, principal mechanisms responsible for the ventricular filling have still remained obscured. Contemporary experimental and clinical investigations unequivocally support the attitude that only powerful suction force, developed by the normal ventricles, would be able to produce an efficient filling of the ventricular cavities. The true origin and the precise time frame for generating such force are still controversial. Elastic recoil and muscular contraction were the most commonly mentioned, but yet, still not clearly explained mechanisms involved in the ventricular suction. Classical concepts about timing of successive mechanical events during the cardiac cycle, also do not offer understandable insight into the mechanism of the ventricular filling. The net result is the current state of insufficient knowledge of systolic and particularly diastolic function of normal and diseased heart. Here we summarize experimental evidence and theoretical backgrounds, which could be useful in understanding the phenomenon of the ventricular filling. Anatomy of the VMB, and recent proofs for its segmental electrical and mechanical activation, undoubtedly indicates that ventricular filling is the consequence of an active muscular contraction. Contraction of the ascendent segment of the VMB, with simultaneous shortening and rectifying of its fibers, produces the paradoxical increase of the ventricular volume and lengthening of its long axis. Specific spatial arrangement of the ascendent segment fibers, their interaction with adjacent descendent segment fibers, elastic elements and intra-cavitary blood volume (hemoskeleton), explain the physical principles

  17. Dye filled security seal

    International Nuclear Information System (INIS)

    Wilson, D.C.

    1982-01-01

    A security seal for providing an indication of unauthorized access to a sealed object includes an elongate member to be entwined in the object such that access is denied unless the member is removed. The elongate member has a hollow, pressurizable chamber extending throughout its length that is filled with a permanent dye under greater than atmospheric pressure. Attempts to cut the member and weld it together are revealed when dye flows through a rupture in the chamber wall and stains the outside surface of the member

  18. Benign gastric filling defect

    International Nuclear Information System (INIS)

    Oh, K. K.; Lee, Y. H.; Cho, O. K.; Park, C. Y.

    1979-01-01

    The gastric lesion is a common source of complaints to Orientals, however, evaluation of gastric symptoms and laboratory examination offer little specific aid in the diagnosis of gastric diseases. Thus roentgenography of gastrointestinal tract is one of the most reliable method for detail diagnosis. On double contract study of stomach, gastric filling defect is mostly caused by malignant gastric cancer, however, other benign lesions can cause similar pictures which can be successfully treated by surgery. 66 cases of benign causes of gastric filling defect were analyzed at this point of view, which was verified pathologically by endoscope or surgery during recent 7 years in Yensei University College of Medicine, Severance Hospital. The characteristic radiological picture of each disease was discussed for precise radiologic diagnosis. 1. Of total 66 cases, there were 52 cases of benign gastric tumor 10 cases of gastric varices, 5 cases of gastric bezoar, 5 cases of corrosive gastritis, 3 cases of granulomatous disease and one case of gastric hematoma. 2. The most frequent causes of benign tumors were adenomatous polyp (35/42) and the next was leiomyoma (4/42). Others were one of case of carcinoid, neurofibroma and cyst. 3. Characteristic of benign adenomatous polyp were relatively small in size, smooth surface and were observed that large size, benign polyp was frequently type IV lesion with a stalk. 4. Submucosal tumors such as leiomyoma needed differential diagnosis with polypoid malignant cancer. However, the characteristic points of differentiation was well circumscribed smooth margined filling defect without definite mucosal destruction on surface. 5. Gastric varices showed multiple lobulated filling defected especially on gastric fundus that changed its size and shape by respiration and posture of patients. Same varices lesions on esophagus and history of liver disease were helpful for easier diagnosis. 6. Gastric bezoar showed well defined movable mass

  19. Benign gastric filling defect

    Energy Technology Data Exchange (ETDEWEB)

    Oh, K. K.; Lee, Y. H.; Cho, O. K.; Park, C. Y. [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1979-06-15

    The gastric lesion is a common source of complaints to Orientals, however, evaluation of gastric symptoms and laboratory examination offer little specific aid in the diagnosis of gastric diseases. Thus roentgenography of gastrointestinal tract is one of the most reliable method for detail diagnosis. On double contract study of stomach, gastric filling defect is mostly caused by malignant gastric cancer, however, other benign lesions can cause similar pictures which can be successfully treated by surgery. 66 cases of benign causes of gastric filling defect were analyzed at this point of view, which was verified pathologically by endoscope or surgery during recent 7 years in Yensei University College of Medicine, Severance Hospital. The characteristic radiological picture of each disease was discussed for precise radiologic diagnosis. 1. Of total 66 cases, there were 52 cases of benign gastric tumor 10 cases of gastric varices, 5 cases of gastric bezoar, 5 cases of corrosive gastritis, 3 cases of granulomatous disease and one case of gastric hematoma. 2. The most frequent causes of benign tumors were adenomatous polyp (35/42) and the next was leiomyoma (4/42). Others were one of case of carcinoid, neurofibroma and cyst. 3. Characteristic of benign adenomatous polyp were relatively small in size, smooth surface and were observed that large size, benign polyp was frequently type IV lesion with a stalk. 4. Submucosal tumors such as leiomyoma needed differential diagnosis with polypoid malignant cancer. However, the characteristic points of differentiation was well circumscribed smooth margined filling defect without definite mucosal destruction on surface. 5. Gastric varices showed multiple lobulated filling defected especially on gastric fundus that changed its size and shape by respiration and posture of patients. Same varices lesions on esophagus and history of liver disease were helpful for easier diagnosis. 6. Gastric bezoar showed well defined movable mass

  20. Benign gastric filling defect

    Energy Technology Data Exchange (ETDEWEB)

    Oh, K K; Lee, Y H; Cho, O K; Park, C Y [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1979-06-15

    The gastric lesion is a common source of complaints to Orientals, however, evaluation of gastric symptoms and laboratory examination offer little specific aid in the diagnosis of gastric diseases. Thus roentgenography of gastrointestinal tract is one of the most reliable method for detail diagnosis. On double contract study of stomach, gastric filling defect is mostly caused by malignant gastric cancer, however, other benign lesions can cause similar pictures which can be successfully treated by surgery. 66 cases of benign causes of gastric filling defect were analyzed at this point of view, which was verified pathologically by endoscope or surgery during recent 7 years in Yensei University College of Medicine, Severance Hospital. The characteristic radiological picture of each disease was discussed for precise radiologic diagnosis. 1. Of total 66 cases, there were 52 cases of benign gastric tumor 10 cases of gastric varices, 5 cases of gastric bezoar, 5 cases of corrosive gastritis, 3 cases of granulomatous disease and one case of gastric hematoma. 2. The most frequent causes of benign tumors were adenomatous polyp (35/42) and the next was leiomyoma (4/42). Others were one of case of carcinoid, neurofibroma and cyst. 3. Characteristic of benign adenomatous polyp were relatively small in size, smooth surface and were observed that large size, benign polyp was frequently type IV lesion with a stalk. 4. Submucosal tumors such as leiomyoma needed differential diagnosis with polypoid malignant cancer. However, the characteristic points of differentiation was well circumscribed smooth margined filling defect without definite mucosal destruction on surface. 5. Gastric varices showed multiple lobulated filling defected especially on gastric fundus that changed its size and shape by respiration and posture of patients. Same varices lesions on esophagus and history of liver disease were helpful for easier diagnosis. 6. Gastric bezoar showed well defined movable mass

  1. The utilization of coal mining wastes as filling materials in reinforced earth structures. III. Construction of a full scale experimental structure; Utilizacion de los esteriles del carbon como material de relleno en estructuras de tierra reforzada. II. Construccion de una estructura experimental

    Energy Technology Data Exchange (ETDEWEB)

    CaNibano Gonzalez, J.; Martinez, C.; Gonzalez, M.R. [HUNOSA. Programa Desarrollo Esteriles. Oviedo (Spain); Pardo, F.; SopeNa, L. [CEDEX. Laboratorio Geotecnia, Madrid (Spain); Torres, M. [Escuela Tecnica Superior de Ingenieros de Minas, Oviedo (Spain); Perez, J.J. [MOPTMA. Demarcacion Carreteras del Estado, Oviedo (Spain)

    1997-06-01

    This article describes the construction of a full scale experimental structure in which coal mining wastes (mine stones) were utilized as a filling material. In such structure, which was 20 m long and 2 high coal mining wastes from two different tips were tested together with different types of reinforcing frames such as metal bands, geomeshes and Paraweb (Freyssisol) bands. Also, thermocouples were placed at different heights. On the other hand, the said structure was subjected to 3.085 passes of a truck having a ballast of 10.5 tons on its rear axle. The performance of the coal mining wastes was completely satisfactory. (Author) 3 refs.

  2. Initial settlements of rock fills on soft clay

    OpenAIRE

    Pedersen, Truls Martens

    2012-01-01

    Rock fills that hit the seabed will remold the underlying material. If this material is a clay with sufficiently low shear strength, it will adopt rheological properties, causing flow through the rock fill, and contributing to the initial settlements of the rock fill in addition to conventional consolidation theory. The settlements of the rocks depend upon the height of the rock fill and how the rocks have been laid out. This is due to the viscosity of the clay, and the fact that clay is thix...

  3. Root canal filling using Resilon: a review.

    LENUS (Irish Health Repository)

    Shanahan, D J

    2011-07-01

    Root canal treatment is achieved by chemo-mechanical debridement of the root canal system followed by filling. The filling material \\'entombs\\' residual bacteria and acts as a barrier which prevents the entrance of oral microorganisms and reinfection of the root canal system through microleakage. However, filling with contemporary root filling materials such as gutta-percha offers limited long-term resistance to microorganisms; as a result other materials such as Resilon have been investigated as alternatives. The aim of this review was to analyse the literature to consider whether Resilon is a suitable root canal filling material. A MEDLINE and Cochrane library search including various keyword searches identified several papers which investigated or discussed Resilon or RealSeal\\/Epiphany. Analysis of the literature demonstrated that the bulk of the literature is in vitro in nature, based largely on leakage-type studies, and demonstrates a wide variety of methodologies with conflicting findings; as a result meaningful conclusions are difficult. Within the limit of these in vitro studies Resilon appears to perform adequately in comparison to gutta-percha, however, as a result of the questionable merit of such studies, it cannot presently be considered an evidence-based alternative to the current gold standard gutta-percha. It is imperative that before Resilon is considered as a replacement material, a better understanding of the physical properties of the resin sealer and the reality of the adhesive \\'monoblock\\' are elucidated. The literature also demonstrates a paucity of quality long-term clinical outcome studies which will need to be addressed before firm conclusions can be reached.

  4. Preparing for faster filling

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    Following the programmed technical stop last week, operators focussed on preparing the machine for faster filling, which includes multibunch injection and a faster pre-cycle phase.   The LHC1 screen shot during the first multibunch injection operation. The LHC operational schedule incorporates a technical stop for preventive maintenance roughly every six weeks of stable operation, during which several interventions on the various machines are carried out. Last week these included the replacement of a faulty magnet in the SPS pre-accelerator, which required the subsequent re-setting of the system of particle extraction and transfer to the LHC. At the end of last week, all the machines were handed back for operation and work could start on accommodating all the changes made into the complex systems in order for normal operation to be resumed. These ‘recovery’ operations continued through the weekend and into this week. At the beginning of this week, operators succeeded in pro...

  5. Alkaline earth filled nickel skutterudite antimonide thermoelectrics

    Science.gov (United States)

    Singh, David Joseph

    2013-07-16

    A thermoelectric material including a body centered cubic filled skutterudite having the formula A.sub.xFe.sub.yNi.sub.zSb.sub.12, where A is an alkaline earth element, x is no more than approximately 1.0, and the sum of y and z is approximately equal to 4.0. The alkaline earth element includes guest atoms selected from the group consisting of Be, Mb, Ca, Sr, Ba, Ra and combinations thereof. The filled skutterudite is shown to have properties suitable for a wide variety of thermoelectric applications.

  6. Curing characteristics of flowable and sculptable bulk-fill composites

    OpenAIRE

    Miletic, Vesna; Pongpruenska, Pong; De Munck, Jan; Brooks, Neil R; Van Meerbeek, Bart

    2016-01-01

    OBJECTIVES: The aim of this study was to determine and correlate the degree of conversion (DC) with Vickers hardness (VH) and translucency parameter (TP) with the depth of cure (DoC) of five bulk-fill composites. MATERIALS AND METHODS: Six specimens per group, consisting of Tetric EvoCeram Bulk Fill ("TEC Bulk," Ivoclar Vivadent), SonicFill (Kerr), SDR Smart Dentin Replacement ("SDR," Dentsply), Xenius base ("Xenius," StickTech; commercialized as EverX Posterior, GC), Filtek Bul...

  7. Fissure fillings from Finnsjoen and Studsvik Sweden

    International Nuclear Information System (INIS)

    Tullborg, E.-L.; Larsson, S.Aa.

    1982-12-01

    Samples were taken from cores and collected at different levels. The bedrock at Finnsjoen is a Svecokarelian granite-granodiorite, the most frequent mineral in the fissures being calcite. The water from boreholes have a mean S 18 O value of -12 per thousand and saturated by calcite. Isotopically three different groups of calcite have been distinguished. Ages of 29+-13x10 3 years to 79+-25x10 3 years were estimated. Two generations of quartz were recognized the minerals prehnite and lanmontite were found Most fissure filling materials have cation exchange capacities. The bedrock at Studsvik is a Svecokarelian gneiss of sedimentary type which is migmatized with calcite and chlorite as fissure filling minerals. Most fissure fillings are thin and simple Claby minerals of smectite type are also frequent. (G.B.)

  8. In vitro evaluation of radiopacity of different filling materials by resources of digital radiography = Avaliação in vitro da radiopacidade de diferentes materiais obturadores através de recursos de radiografia digital

    Directory of Open Access Journals (Sweden)

    Souza, Matheus Albino

    2015-01-01

    Full Text Available Objetivo: Avaliar a radiopacidade de diferentes sistemas obturadores endodônticos por meio de radiografia digital em um modelo de dentes humanos. Metodologia: Setenta dentes humanos unirradiculares extraídos foram selecionados, a abertura coronária foi feita e o comprimento de trabalho foi determinado 1 mm aquém do forame apical. Após o preparo químicomecânico os dentes foram divididos em 7 grupos [n=10] de acordo com o material obturador utilizado: G1, Epiphany; G2, AH Plus; G3, EndoRez; G4, EndoFill; G5, Endomethasone; G6, Sealapex; G7, Sealer 26. No G1 foram utilizados cones de Resilon e nos demais grupos cones de guta-percha. Sete dias após a obturação foram feitas radiografias digitais e as imagens foram introduzidas num software para a leitura dos resultados. Para avaliar a radiopacidade, o software digitale DBSWIN gerou um gráfico colorimétrico para cada amostra, relacionando o gradiente de cor observado na amostra com o respectivo escore numérico contido em uma escala desse gráfico. Os dados foram analisados estaticamente pelo teste ANOVA e Tukey’s ao nível de 5% de significância. Resultados: O sistema Epiphany/Resilon foi superior estatisticamente aos grupos do AH Plus, EndoRez, Sealapex e Sealer 26 em termos de radiopacidade [P<0,05]. Conclusão: O cimento endodôntico Epiphany, associado aos cones Resilon, apresentou os maiores valores de radiopacidade

  9. Improving the support characteristics of hydraulic fill

    Energy Technology Data Exchange (ETDEWEB)

    Corson, D. R.; Dorman, K. R.; Sprute, R. H.

    1980-05-15

    Extensive laboratory and field testing has defined the physical properties of hydraulic fill. Effect of void ratio on percolation rate has been quantified, and tests were developed to estimate waterflow through fill material in a given state underground. Beneficial effect on fill's support capability through addition of cement alone or in conjunction with vibratory compaction has been investigated. Two separate field studies in operating cut-and-fill mines measured vein-wall deformation and loads imposed on backfilled stopes. Technology has been developed that will effectively and efficiently dewater and densify ultra-fine-grained slurries typical of metal mine hydraulic backfill. At least two operators are using this electrokinetic technique to dewater slimes collected in underground sumps or impoundments. This technique opens up the possibility of using the total unclassified tailings product as a hydraulic backfill. Theoretical enhancement of ground support and rock-burst control through improved support capability will be tested in a full-scale mine stope installation. Both a horizontal layer and a vertical column of high modulus fill will be placed in an attempt to reduce stope wall closure, support more ground pressure, and lessen rock-burst occurrence.

  10. 46 CFR 151.03-21 - Filling density.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Filling density. 151.03-21 Section 151.03-21 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES BARGES CARRYING BULK LIQUID HAZARDOUS MATERIAL CARGOES Definitions § 151.03-21 Filling density. The ratio, expressed as...

  11. Boron filled siloxane polymers for radiation shielding

    Science.gov (United States)

    Labouriau, Andrea; Robison, Tom; Shonrock, Clinton; Simmonds, Steve; Cox, Brad; Pacheco, Adam; Cady, Carl

    2018-03-01

    The purpose of the present work was to evaluate changes to structure-property relationships of 10B filled siloxane-based polymers when exposed to nuclear reactor radiation. Highly filled polysiloxanes were synthesized with the intent of fabricating materials that could shield high neutron fluences. The newly formulated materials consisted of cross-linked poly-diphenyl-methylsiloxane filled with natural boron and carbon nanofibers. This polymer was chosen because of its good thermal and chemical stabilities, as well as resistance to ionizing radiation thanks to the presence of aromatic groups in the siloxane backbone. Highly isotopically enriched 10B filler was used to provide an efficient neutron radiation shield, and carbon nanofibers were added to improve mechanical strength. This novel polymeric material was exposed in the Annular Core Research Reactor (ACRR) at Sandia National Labs to five different neutron/gamma fluxes consisting of very high neutron fluences within very short time periods. Thermocouples placed on the specimens recorded in-situ temperature changes during radiation exposure, which agreed well with those obtained from our MCNP simulations. Changes in the microstructural, thermal, chemical, and mechanical properties were evaluated by SEM, DSC, TGA, FT-IR NMR, solvent swelling, and uniaxial compressive load measurements. Our results demonstrate that these newly formulated materials are well-suitable to be used in applications that require exposure to different types of ionizing conditions that take place simultaneously.

  12. Dielectric-filled radiofrequency linacs

    Energy Technology Data Exchange (ETDEWEB)

    Faehl, R J; Keinigs, R K; Pogue, E W [Los Alamos National Lab., NM (United States)

    1997-12-31

    High current, high brightness electron beam accelerators promise to open up dramatic new applications. Linear induction accelerators are currently viewed as the appropriate technology for these applications. A concept by Humphries and Hwang may permit radiofrequency accelerators to fulfill the same functions with greater simplicity and enhanced flexibility. This concept involves the replacement of vacuum rf cavities with dielectric filled ones. Simple analysis indicates that the resonant frequencies are reduced by a factor of ({epsilon}{sub 0}/{epsilon}){sup 1/2} while the stored energy is increased by {epsilon}/{epsilon}{sub 0}. For a high dielectric constant like water, this factor can approach 80. A series of numerical calculations of simple pill-box cavities was performed. Eigenfunctions and resonant frequencies for a full system configuration, including dielectric material, vacuum beamline, and a ceramic window separating the two have been computed. These calculations are compared with the results of a small experimental cavity which have been constructed and operated. Low power tests show excellent agreement. (author). 4 figs., 8 refs.

  13. Gas-filled hohlraum fabrication

    International Nuclear Information System (INIS)

    Salazar, M.A.; Gobby, P.L.; Foreman, L.R.; Bush, H. Jr.; Gomez, V.M.; Moore, J.E.; Stone, G.F.

    1995-01-01

    Los Alamos National Laboratory (LANL) researchers have fabricated and fielded gas-filled hohlraums at the Lawrence Livermore National Laboratory (LLNL) Nova laser. Fill pressures of 1--5 atmospheres have been typical. We describe the production of the parts, their assembly and fielding. Emphasis is placed on the production of gas-tight polyimide windows and the fielding apparatus and procedure

  14. Time effects of water drainage from deposited back-fill

    International Nuclear Information System (INIS)

    Baranski, L.A.

    1976-01-01

    Time effects of water drainage from deposited back-fill in mine excavations are considered. The time dependence of drainage from the deposited material was determined from ''in situ'' measurements with the aid of radioisotope gauges. The measurements were performed for given drainage conditions and practically constant grain size composition. It was found that in a few hours after the end of the back-filling operation the mechanical properties of the deposited material are practically constant. (author)

  15. Recent developments in inorganically filled carbon nanotubes: successes and challenges

    Directory of Open Access Journals (Sweden)

    Ujjal K Gautam, Pedro M F J Costa, Yoshio Bando, Xiaosheng Fang, Liang Li, Masataka Imura and Dmitri Golberg

    2010-01-01

    Full Text Available Carbon nanotubes (CNTs are a unique class of nanomaterials that can be imagined as rolled graphene sheets. The inner hollow of a CNT provides an extremely small, one-dimensional space for storage of materials. In the last decade, enormous effort has been spent to produce filled CNTs that combine the properties of both the host CNT and the guest filling material. CNTs filled with various inorganic materials such as metals, alloys, semiconductors and insulators have been obtained using different synthesis approaches including capillary filling and chemical vapor deposition. Recently, several potential applications have emerged for these materials, such as the measurement of temperature at the nanoscale, nano-spot welding, and the storage and delivery of extremely small quantities of materials. A clear distinction between this class of materials and other nanostructures is the existence of an enormous interfacial area between the CNT and the filling matter. Theoretical investigations have shown that the lattice mismatch and strong exchange interaction of CNTs with the guest material across the interface should result in reordering of the guest crystal structure and passivation of the surface dangling bonds and thus yielding new and interesting physical properties. Despite preliminary successes, there remain many challenges in realizing applications of CNTs filled with inorganic materials, such as a comprehensive understanding of their growth and physical properties and control of their structural parameters. In this article, we overview research on filled CNT nanomaterials with special emphasis on recent progress and key achievements. We also discuss the future scope and the key challenges emerging out of a decade of intensive research on these fascinating materials.

  16. Better building of valley fills

    Energy Technology Data Exchange (ETDEWEB)

    Chironis, N.P.

    1980-03-01

    Current US regulations for building valley fills or head of hollow fills to hold excess spoil resulting from contour mining are meeting with considerable opposition, particularly from operators in steep-slope areas. An alternative method has been submitted to the Office of Surface Mining by Virgina. Known as the zoned concept method, it has already been used successfully in building water-holding dams and coal refuse embankments on sloping terrain. The ways in which drainage and seepage are managed are described.

  17. Magnetically Active and Coated Gadolinium-Filled Carbon Nanotubes

    KAUST Repository

    Fidiani, Elok; Da Costa, Pedro M. F. J.; Wolter, Anja U. B.; Maier, Diana; Buechner, Bernd; Hampel, Silke

    2013-01-01

    Gd-filled carbon nanotubes (which include the so-called gadonanotubes(1)) have been attracting much interest due to their potential use in medical diagnostic applications. In the present work, a vacuum filling method was performed to confine gadolinium(III) iodide in carbon nanotubes (CNTs). Filling yields in excess of 50% were obtained. Cleaning and dosing of the external walls was undertaken, as well as the study of the filled CNT magnetic properties. Overall, we found that the encapsulating procedure can lead to reduction of the lanthanide metal and induce disorder in the initial GdI3-type structure. Notwithstanding, the magnetic response of the material is not compromised, retaining a strong paramagnetic response and an effective magnetic moment of similar to 6 mu B. Our results may entice further investigation into whether an analogous Gd3+ to Gd2+ reduction takes place in other Gd-filled CNT systems.

  18. Magnetically Active and Coated Gadolinium-Filled Carbon Nanotubes

    KAUST Repository

    Fidiani, Elok

    2013-08-15

    Gd-filled carbon nanotubes (which include the so-called gadonanotubes(1)) have been attracting much interest due to their potential use in medical diagnostic applications. In the present work, a vacuum filling method was performed to confine gadolinium(III) iodide in carbon nanotubes (CNTs). Filling yields in excess of 50% were obtained. Cleaning and dosing of the external walls was undertaken, as well as the study of the filled CNT magnetic properties. Overall, we found that the encapsulating procedure can lead to reduction of the lanthanide metal and induce disorder in the initial GdI3-type structure. Notwithstanding, the magnetic response of the material is not compromised, retaining a strong paramagnetic response and an effective magnetic moment of similar to 6 mu B. Our results may entice further investigation into whether an analogous Gd3+ to Gd2+ reduction takes place in other Gd-filled CNT systems.

  19. Safety Distances for hydrogen filling stations

    Energy Technology Data Exchange (ETDEWEB)

    Matthijsen, A. J. C. M.; Kooi, E. S.

    2005-07-01

    In the Netherlands there is a growing interest in using natural gas as a transport fuel. The most important drivers behind this development are formed by poor inner city air quality and the decision to close several LPG filling stations. Dwellings are not allowed within the safety distances of 45 or 110 meters from the tanker filling point of these LPG stations, depending on the capacity of the station. Another driver is global warming. We are carrying out a study on station supply, compression, storage and filling for natural gas stations, and a similar, simultaneous study on hydrogen as a followup to our risk analysis for the hydrogen filling station in Amsterdam. Here, three buses drive on hydrogen as part of the European CUTE project. Driving on natural gas is an important step in the transition to cars on hydrogen. This study was commissioned by the Dutch Ministry of Spatial Planning, Housing and the Environment to advise on external safety aspects of future hydrogen filling stations. According to Dutch law homes may not be built within an individual risk contour of 10-6 per year of a dangerous object, such as a plant with hazardous materials or a filling station. An individual risk contour of 10-6 is represented by a line around a dangerous object that connects locations with an individual risk level of 10-6 per year. An individual 'located' within this contour line has a chance of one per million per year or more to be killed as a result of an accident caused by this object. The longest distance between the object and such a contour is called a 'safety distance'. A study on safety distances is now in progress for different kinds of hydrogen filling stations (e. g. gaseous and liquid hydrogen) and for different capacities, such as big, medium and small stations. The focus is on different kinds of hydrogen production and the hydrogen supply of the filling station. To decide on the design and supply of the hydrogen station, we examined the

  20. Materialism.

    Science.gov (United States)

    Melnyk, Andrew

    2012-05-01

    Materialism is nearly universally assumed by cognitive scientists. Intuitively, materialism says that a person's mental states are nothing over and above his or her material states, while dualism denies this. Philosophers have introduced concepts (e.g., realization and supervenience) to assist in formulating the theses of materialism and dualism with more precision, and distinguished among importantly different versions of each view (e.g., eliminative materialism, substance dualism, and emergentism). They have also clarified the logic of arguments that use empirical findings to support materialism. Finally, they have devised various objections to materialism, objections that therefore serve also as arguments for dualism. These objections typically center around two features of mental states that materialism has had trouble in accommodating. The first feature is intentionality, the property of representing, or being about, objects, properties, and states of affairs external to the mental states. The second feature is phenomenal consciousness, the property possessed by many mental states of there being something it is like for the subject of the mental state to be in that mental state. WIREs Cogn Sci 2012, 3:281-292. doi: 10.1002/wcs.1174 For further resources related to this article, please visit the WIREs website. Copyright © 2012 John Wiley & Sons, Ltd.

  1. Optimization of foam-filled bitubal structures for crashworthiness criteria

    International Nuclear Information System (INIS)

    Zhang, Yong; Sun, Guangyong; Li, Guangyao; Luo, Zhen; Li, Qing

    2012-01-01

    Highlights: ► The paper aims to optimize foam-filled bitubal squared column for crashworthiness. ► It explores different formulations and configurations of design. ► The optimal foam-filled bitubal column is better than foam-filled monotubal column. ► The optimal foam-filled bitubal column is better than empty bitubal column. -- Abstract: Thin-walled structures have been widely used as key components in automobile and aerospace industry to improve the crashworthiness and safety of vehicles while maintaining overall light-weight. This paper aims to explore the design issue of thin-walled bitubal column structures filled with aluminum foam. As a relatively new filler material, aluminum foam can increase crashworthiness without sacrificing too much weight. To optimize crashworthiness of the foam-filled bitubal square column, the Kriging meta-modeling technique is adopted herein to formulate the objective and constraint functions. The genetic algorithm (GA) and Non-dominated Sorting Genetic Algorithm II (NSGA II) are used to seek the optimal solutions to the single and multiobjective optimization problems, respectively. To compare with other thin-walled configurations, the design optimization is also conducted for empty bitubal column and foam-filled monotubal column. The results demonstrate that the foam-filled bitubal configuration has more room to enhance the crashworthiness and can be an efficient energy absorber.

  2. Bulk-fill resin composites: polymerization contraction, depth of cure, and gap formation.

    Science.gov (United States)

    Benetti, A R; Havndrup-Pedersen, C; Honoré, D; Pedersen, M K; Pallesen, U

    2015-01-01

    The bulk-filling of deep, wide dental cavities is faster and easier than traditional incremental restoration. However, the extent of cure at the bottom of the restoration should be carefully examined in combination with the polymerization contraction and gap formation that occur during the restorative procedure. The aim of this study, therefore, was to compare the depth of cure, polymerization contraction, and gap formation in bulk-fill resin composites with those of a conventional resin composite. To achieve this, the depth of cure was assessed in accordance with the International Organization for Standardization 4049 standard, and the polymerization contraction was determined using the bonded-disc method. The gap formation was measured at the dentin margin of Class II cavities. Five bulk-fill resin composites were investigated: two high-viscosity (Tetric EvoCeram Bulk Fill, SonicFill) and three low-viscosity (x-tra base, Venus Bulk Fill, SDR) materials. Compared with the conventional resin composite, the high-viscosity bulk-fill materials exhibited only a small increase (but significant for Tetric EvoCeram Bulk Fill) in depth of cure and polymerization contraction, whereas the low-viscosity bulk-fill materials produced a significantly larger depth of cure and polymerization contraction. Although most of the bulk-fill materials exhibited a gap formation similar to that of the conventional resin composite, two of the low-viscosity bulk-fill resin composites, x-tra base and Venus Bulk Fill, produced larger gaps.

  3. Gas-Filled Capillary Model

    International Nuclear Information System (INIS)

    Steinhauer, L. C.; Kimura, W. D.

    2006-01-01

    We have developed a 1-D, quasi-steady-state numerical model for a gas-filled capillary discharge that is designed to aid in selecting the optimum capillary radius in order to guide a laser beam with the required intensity through the capillary. The model also includes the option for an external solenoid B-field around the capillary, which increases the depth of the parabolic density channel in the capillary, thereby allowing for propagation of smaller laser beam waists. The model has been used to select the parameters for gas-filled capillaries to be utilized during the Staged Electron Laser Acceleration -- Laser Wakefield (STELLA-LW) experiment

  4. Filling of charged cylindrical capillaries

    NARCIS (Netherlands)

    Das, Siddhartha; Chanda, Sourayon; Eijkel, J.C.T.; Tas, N.R.; Chakraborty, Suman; Mitra, Sushanta K.

    2014-01-01

    We provide an analytical model to describe the filling dynamics of horizontal cylindrical capillaries having charged walls. The presence of surface charge leads to two distinct effects: It leads to a retarding electrical force on the liquid column and also causes a reduced viscous drag force because

  5. Space-filling polyhedral sorbents

    Energy Technology Data Exchange (ETDEWEB)

    Haaland, Peter

    2016-06-21

    Solid sorbents, systems, and methods for pumping, storage, and purification of gases are disclosed. They derive from the dynamics of porous and free convection for specific gas/sorbent combinations and use space filling polyhedral microliths with facial aplanarities to produce sorbent arrays with interpenetrating interstitial manifolds of voids.

  6. ADVANTAGES AND DISADVANTAGES OF THE SONICFILL™ METHOD FOR LATERAL FILLINGS

    Directory of Open Access Journals (Sweden)

    Nicolae BARANOV

    2017-06-01

    Full Text Available The aim of the study was to evaluate the advantages and disadvantages of bulk-fill type fillings realized with SONICFill™ over an 18 month interval, on a batch of patients with different ages and occupations. Materials and methods: the study was performed on a batch of 73 patients who addressed the Clinical of OdontologyEndodontics within the Platform of Practical Training (PIP of the Faculty of Dental Medicine of the ”Apollonia” University of Iaşi, between Octomber 1, 2014 - May 1, 2016, subjected to 91 bulk-fill fillings with SonicFill™ on the posterior teeth. Results and discussion: out of the total number of 73 patients, 56 came from the urban environment, and 17 - from the rural medium, the highest ratio being represented by the 21-30 year age group (45%, closely followed by the 31-40 year one (40%. As for gender distribution within the batch, nearly two-thirds are women, the rest being men. The education level influenced patients’ decision – that of accepting a new method of filling application. As to the types of teeth to which restorations were applied, the highest ratio is represented by lower molars (41%, followed by upper molars (23% and mandibular premolars (20%, the lowest number of restorations being applied to maxillary premolars. Out of the total number of 91 bulk-fill restorations, 28 were applied over a base filling while, in 63 restorations, the basic filling was absent. Conclusions: The SonicFill ™ system for bulk-fill posterior restorations has a number of advantages, such as: high photopolymerization depth, significant reduction of setting contraction, better composite adaptation to the cavity walls, long-term predictable clinical results.

  7. Incidence of apical crack initiation and propagation during the removal of root canal filling material with ProTaper and Mtwo rotary nickel-titanium retreatment instruments and hand files.

    Science.gov (United States)

    Topçuoğlu, Hüseyin Sinan; Düzgün, Salih; Kesim, Bertan; Tuncay, Oznur

    2014-07-01

    The aim of this study was to determine the incidence of crack initiation and propagation in apical root dentin after retreatment procedures performed by using 2 rotary retreatment systems and hand files with additional instrumentation. Eighty extracted mandibular premolars with single canals were selected. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the control group, and no preparation was performed. The remaining 60 teeth were prepared to size 35 with rotary files and filled with gutta-percha and AH Plus sealer. Specimens were then divided into 3 groups (n = 20), and retreatment procedures were performed with the following devices and techniques: ProTaper Universal retreatment files, Mtwo retreatment files, and hand files. After retreatment, the additional instrumentation was performed by using size 40 ProTaper, Mtwo, and hand files. Digital images of the apical root surface were recorded before preparation, after instrumentation, after filling, after retreatment, and after additional instrumentation. The images were then inspected for the presence of any new apical cracks and propagation. Data were analyzed with the logistic regression and Fisher exact tests. All experimental groups caused crack initiation and propagation after use of retreatment instruments. The ProTaper and Mtwo retreatment groups caused greater crack initiation and propagation than the hand instrument group (P ProTaper and Mtwo instruments after the use of retreatment instruments caused crack initiation and propagation, whereas hand files caused neither crack initiation nor propagation (P < .05). This study showed that retreatment procedures and additional instrumentation after the use of retreatment files may cause crack initiation and propagation in apical dentin. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  8. Materials

    CSIR Research Space (South Africa)

    Van Wyk, Llewellyn V

    2009-02-01

    Full Text Available . It is generally included as part of a structurally insulated panel (SIP) where the foam is sandwiched between external skins of steel, wood or cement. Cement composites Cement bonded composites are an important class of building materials. These products... for their stone buildings, including the Egyptians, Aztecs and Inca’s. As stone is a very dense material it requires intensive heating to become warm. Rocks were generally stacked dry but mud, and later cement, can be used as a mortar to hold the rocks...

  9. Understanding the safety and tolerability of facial filling therapeutics.

    Science.gov (United States)

    Kulichova, Daniela; Borovaya, Alyona; Ruzicka, Thomas; Thomas, Peter; Gauglitz, Gerd G

    2014-09-01

    Aesthetic medicine represents an emerging field for many specialties. Nowadays, a plethora of approaches are available to rejuvenate the human body and face, the latter being a frequent target for the placement of filling substances to correct wrinkles and volume loss. Nevertheless, based on the many products on the market, treating clinicians must pay specific attention to the properties of the respective materials, their associated side effects and any specific handling requirements to prevent potential short- and long-term adverse events. Types of filling materials, including biodegradable and non-biodegradable products, related complications, their conservative and invasive treatment options, as well as prevention strategies are described in this review. A profound knowledge of the facial anatomy as well as extensive experience with the various filling techniques and suitable materials for the respective areas remains crucial to prevent adverse events associated with filling procedures to the human face. Since side effects such as malar edema and foreign body granuloma do affect patients physically and psychologically to a significant extent and their successful treatment still remains challenging, further in depth studies on the tolerability of many filling materials utilized are required.

  10. Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance.

    Science.gov (United States)

    Ilie, N; Bucuta, S; Draenert, M

    2013-01-01

    The study aimed to assess the mechanical performance of seven bulk-fill RBCs (Venus Bulk Fill, Heraeus Kulzer; SureFil SDR flow, Dentsply Caulk; x-tra base and x-tra fil, VOCO; Filtek Bulk Fill, 3M ESPE; SonicFill, Kerr; Tetric EvoCeram Bulk Fill, Ivoclar Vivadent) by determining their flexural strength (σ), reliability (Weibull parameter, m), flexural modulus (Eflexural), indentation modulus (YHU), Vickers hardness (HV), and creep (Cr). The significant highest flexural strengths were measured for SonicFill, x-tra base, and x-tra fil, while x-tra base, SureFil SDR flow, and Venus Bulk Fill showed the best reliability. The differences among the materials became more evident in terms of Eflexural and YHU, with x-tra fil achieving the highest values, while Filtek Bulk Fill and Venus Bulk Fill achieved the lowest. The enlarged depth of cure in bulk-fill RBCs seems to have been realized by enhancing the materials' translucency through decreasing the filler amount and increasing the filler size. The manufacturer's recommendation to finish a bulk-fill RBC restoration by adding a capping layer made of regular RBCs is an imperative necessity, since the modulus of elasticity and hardness of certain materials (SureFil SDR flow, Venus Bulk Fill, and Filtek Bulk Fill) were considerably below the mean values measured in regular nanohybrid and microhybrid RBCs. The class of bulk-fill RBCs revealed similar flexural strength values as the class of nanohybrid and microhybrid RBCs, and significantly higher values when compared to flowable RBCs. The modulus of elasticity (Eflexural), the indentation modulus (YHU), and the Vickers hardness (HV) classify the bulk-fill RBCs as between the hybrid RBCs and the flowable RBCs; in terms of creep, bulk-fill and the flowable RBCs perform similarly, both showing a significantly lower creep resistance when compared to the nanohybrid and microhybrid RBCs.

  11. Hard-to-fill vacancies.

    Science.gov (United States)

    Williams, Ruth

    2010-09-29

    Skills for Health has launched a set of resources to help healthcare employers tackle hard-to-fill entry-level vacancies and provide sustainable employment for local unemployed people. The Sector Employability Toolkit aims to reduce recruitment and retention costs for entry-level posts and repare people for employment through pre-job training programmes, and support employers to develop local partnerships to gain access to wider pools of candidates and funding streams.

  12. Hydraulic fracturing of rock-fill dam

    Directory of Open Access Journals (Sweden)

    Jun-Jie WANG

    2016-02-01

    Full Text Available The condition in which hydraulic fracturing in core of earth-rock fill dam maybe induced, the mechanism by which the reason of hydraulic fracturing canbe explained, and the failure criterion by which the occurrence of hydraulicfracturing can be determined, were investigated. The condition dependson material properties such as, cracks in the core and low permeability ofcore soil, and “water wedging” action in cracks. An unsaturated core soiland fast impounding are the prerequisites for the formation of “waterwedging” action. The mechanism of hydraulic fracturing can be explainedby fracture mechanics. The crack propagation induced by water pressuremay follow any of mode I, mode II and mixed mode I-II. Based on testingresults of a core soil, a new criterion for hydraulic fracturing was suggested,from which mechanisms of hydraulic fracturing in the core of rock-fill damwere discussed. The results indicated that factors such as angle betweencrack surface and direction of principal stress, local stress state at thecrack, and fracture toughness KIC of core soil may largely affect theinduction of hydraulic fracturing and the mode of the propagation of thecrack.The condition in which hydraulic fracturing in core of earth-rock fill dam maybe induced, the mechanism by which the reason of hydraulic fracturing canbe explained, and the failure criterion by which the occurrence of hydraulicfracturing can be determined, were investigated. The condition dependson material properties such as, cracks in the core and low permeability ofcore soil, and “water wedging” action in cracks. An unsaturated core soiland fast impounding are the prerequisites for the formation of “waterwedging” action. The mechanism of hydraulic fracturing can be explainedby fracture mechanics. The crack propagation induced by water pressuremay follow any of mode I, mode II and mixed mode I-II. Based on testingresults of a core soil, a new criterion for hydraulic fracturing

  13. Post-cure depth of cure of bulk fill dental resin-composites.

    Science.gov (United States)

    Alrahlah, A; Silikas, N; Watts, D C

    2014-02-01

    To determine the post-cure depth of cure of bulk fill resin composites through using Vickers hardness profiles (VHN). Five bulk fill composite materials were examined: Tetric EvoCeram(®) Bulk Fill, X-tra base, Venus(®) Bulk Fill, Filtek™ Bulk Fill, SonicFill™. Three specimens of each material type were prepared in stainless steel molds which contained a slot of dimensions (15 mm × 4 mm × 2 mm), and a top plate. The molds were irradiated from one end. All specimens were stored at 37°C for 24h, before measurement. The Vickers hardness was measured as a function of depth of material, at 0.3mm intervals. Data were analysed by one-way ANOVA using Tukey post hoc tests (α=0.05). The maximum VHN ranged from 37.8 to 77.4, whilst the VHN at 80% of max.VHN ranged from 30.4 to 61.9. The depth corresponding to 80% of max.VHN, ranged from 4.14 to 5.03 mm. One-way ANOVA showed statistically significant differences between materials for all parameters tested. SonicFill exhibited the highest VHN (pFill the lowest (p≤0.001). SonicFill and Tetric EvoCeram Bulk Fill had the greatest depth of cure (5.03 and 4.47 mm, respectively) and was significant's different from X-tra base, Venus Bulk Fill and Filtek Bulk Fill (p≤0.016). Linear regression confirmed a positive regression between max.VHN and filler loading (r(2)=0.94). Bulk fill resin composites can be cured to an acceptable post-cure depth, according to the manufacturers' claims. SonicFill and Tetric EvoCeram Bulk Fill had the greatest depth of cure among the composites examined. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  14. 30 CFR 817.72 - Disposal of excess spoil: Valley fill/head-of-hollow fills.

    Science.gov (United States)

    2010-07-01

    ... STANDARDS-UNDERGROUND MINING ACTIVITIES § 817.72 Disposal of excess spoil: Valley fill/head-of-hollow fills.... Uncontrolled surface drainage may not be directed over the outslope of the fill. (2) Runoff from areas above the fill and runoff from the surface of the fill shall be diverted into stabilized diversion channels...

  15. Fissure fillings from the Klipperaas study site

    International Nuclear Information System (INIS)

    Tullborg, E.L.

    1986-07-01

    The Klipperaas study site is located within the Smaaland-Vaermland granitoid belt in southern Sweden. The area investigated can be subdivided into blocks with different hydraulic character and fracture frequency of the rocks. A fissure filling, study has been carried out within the area. This includes identification of the minerals, mineral frequency, textures within the fissures and isotope analyses of calcites. Four generation of fissure fillings, within the time space c. 1600 M.a. to present, has been distinguished. These are 1) quartz; 2) epidote + muscovite and adularia + hematite; 3) calcite + chlorite +/hematite; 4) calcite, clay minerals and Fe-oxyhydroxide. It is observed that the surface water affect the uppermost part of the bedrock resulting in calcite dissolution, break down of pyrite and precipitation of Fe-oxyhydroxide. It is also obvious from the fracture calcite frequency that calcite dissolution is more intensive close to and within the fracture zones. There, Fe-oxyhydroxide can be found down to at least 400 m depth. This gives valuable information about the physic-chemical character of the groundwater within the bedrock. Several fracture zones have been reactivated. It is also suspected that relatively late movements have taken place causing crushing of the rock and only a slight cementation of the crushed material is visible. Some of the fracture zones correspond to mafic dikes. These zones exhibit lower hydraulic conductivity than other zones due to fracture sealing by clay minerals but also by chlorite and calcite. (author)

  16. Charge balancing fill rate monitor

    International Nuclear Information System (INIS)

    Rothman, J.L.; Blum, E.B.

    1995-01-01

    A fill rate monitor has been developed for the NSLS storage rings to allow machine tuning over a very large dynamic range of beam current. Synchrotron light, focused on a photodiode, produces a signal proportional to the beam current. A charge balancing circuit processes the diode current, creating an output signal proportional to the current injected into the ring. The unit operates linearly over a dynamic range of 120 dB and can resolve pulses of injected beam as small as 1 μA

  17. Modelling the filling rate of pit latrines | Brouckaert | Water SA

    African Journals Online (AJOL)

    Excreta (faeces and urine) that are deposited into a pit latrine are subject to biodegradation, which substantially reduces the volume that remains. On the other hand, other matter that is not biodegradable usually finds itsway into pit latrines. The net filling rate is thus dependent on both the rate of addition of material and its ...

  18. The Effects of Iron Filling On Some Mechanical and Physical ...

    African Journals Online (AJOL)

    acer

    sawdust of particle size 1.18mm and iron fillings of size 300µm, 20g binder (urea formaldehyde) concentration, hot ... The water absorption and thickness swell test results showed that the .... of this type of magnetic material include: easier.

  19. Elution of monomer from different bulk fill dental composite resins.

    Science.gov (United States)

    Cebe, Mehmet Ata; Cebe, Fatma; Cengiz, Mehmet Fatih; Cetin, Ali Rıza; Arpag, Osman Fatih; Ozturk, Bora

    2015-07-01

    The purpose of this study was to evaluate the elution of Bis-GMA, TEGDMA, HEMA, and Bis-EMA monomers from six bulk fill composite resins over four different time periods, using HPLC. Six different composite resin materials were used in the present study: Tetric Evo Ceram Bulk Fill (Ivoclar Vivadent, Amherst, NY), X-tra Fill (VOCO, Cuxhaven, Germany), Sonic Fill (Kerr, Orange, CA, USA), Filtek Bulk Fill (3M ESPE Dental Product, St. Paul, MN), SDR (Dentsply, Konstanz, Germany), EQUIA (GC America INC, Alsip, IL). The samples (4mm thickness, 5mm diameter) were prepared and polymerized for 20s with a light emitted diode unit. After fabrication, each sample was immediately immersed in 75wt% ethanol/water solution used as extraction fluid and stored in the amber colored bottles at room temperature. Ethanol/water samples were taken (0.5mL) at predefined time intervals:10m (T1), 1h (T2), 24h (T3) and 30 days (T4). These samples were analyzed by HPLC. The obtained data were analyzed with one-way ANOVA and Tukey HSD at significance level of pcomposites (pcomposite resins in all time periods and the amount of eluted monomers was increased with time. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  20. Vertical Scan-Conversion for Filling Purposes

    OpenAIRE

    Hersch, R. D.

    1988-01-01

    Conventional scan-conversion algorithms were developed independently of filling algorithms. They cause many problems, when used for filling purposes. However, today's raster printers and plotters require extended use of filling, especially for the generation of typographic characters and graphic line art. A new scan-conversion algorithm, called vertical scan-conversion has been specifically designed to meet the requirements of parity scan line fill algorithms. Vertical scan-conversion ensures...

  1. 7 CFR 58.923 - Filling containers.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Filling containers. 58.923 Section 58.923 Agriculture... Procedures § 58.923 Filling containers. (a) The filling of small containers with product shall be done in a sanitary manner. The containers shall not contaminate or detract from the quality of the product in any way...

  2. Bulk fill restoratives: to cap or not to cap--that is the question?

    Science.gov (United States)

    Tomaszewska, Iwona M; Kearns, Jennifer O; Ilie, Nicoleta; Fleming, Garry J P

    2015-03-01

    To assess the cuspal deflection and cervical microleakage scores of standardised large mesio-occlusal-distal (MOD) cavities filled with different restoration protocols: (1) conventional resin restoratives, (2) bulk fill flowable base materials 'capped' with a conventional dimethacrylate resin-based composite (RBC) or (3) bulk fill resin restorative materials. Standardised MOD cavities were prepared in sixty-four sound maxillary premolar teeth and randomly allocated to eight groups. Restorations were placed in conjunction with a universal bonding system and resin restorative materials were irradiated with a quartz-tungsten-halogen light-curing-unit. Restoration protocol (eight oblique increments of conventional resin restorative, bulk fill flowable base and two occlusal 'capping' RBC increments (three increments in total) or bulk fill resin restorative (two increments)) was the dependent variable. A twin channel deflection measuring gauge measured the buccal and palatal cuspal deflections. Teeth were thermally fatigued, immersed in a 0.2% basic fuchsin dye for 24h, sectioned and examined for cervical microleakage score. Post hoc Tukey's tests highlighted significant differences in the mean total cuspal deflection values between resin restoratives (p fill flowable base materials with occlusal 'capping' RBC increments (restoration protocol 2) compared with bulk fill resin restoratives (restoration protocol 3). Not all bulk fill flowable materials or bulk fill resin restoratives behave in a similar fashion when used to restore standardised MOD cavities in maxillary premolar teeth and material selection is vital in the absence of clinical data. Poorly performing bulk fill flowable materials or bulk fill restoratives can be identified using the cuspal deflection and cervical microleakage protocol which could save the complications encountered clinically when restoring Class II restorations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Spectral radiative property control method based on filling solution

    International Nuclear Information System (INIS)

    Jiao, Y.; Liu, L.H.; Hsu, P.-F.

    2014-01-01

    Controlling thermal radiation by tailoring spectral properties of microstructure is a promising method, can be applied in many industrial systems and have been widely researched recently. Among various property tailoring schemes, geometry design of microstructures is a commonly used method. However, the existing radiation property tailoring is limited by adjustability of processed microstructures. In other words, the spectral radiative properties of microscale structures are not possible to change after the gratings are fabricated. In this paper, we propose a method that adjusts the grating spectral properties by means of injecting filling solution, which could modify the thermal radiation in a fabricated microstructure. Therefore, this method overcomes the limitation mentioned above. Both mercury and water are adopted as the filling solution in this study. Aluminum and silver are selected as the grating materials to investigate the generality and limitation of this control method. The rigorous coupled-wave analysis is used to investigate the spectral radiative properties of these filling solution grating structures. A magnetic polaritons mechanism identification method is proposed based on LC circuit model principle. It is found that this control method could be used by different grating materials. Different filling solutions would enable the high absorption peak to move to longer or shorter wavelength band. The results show that the filling solution grating structures are promising for active control of spectral radiative properties. -- Highlights: • A filling solution grating structure is designed to adjust spectral radiative properties. • The mechanism of radiative property control is studied for engineering utilization. • Different grating materials are studied to find multi-functions for grating

  4. Dynamic compaction with high energy of sandy hydraulic fills

    Directory of Open Access Journals (Sweden)

    Khelalfa Houssam

    2017-09-01

    Full Text Available A case study about the adoption of the dynamic compaction technique with high energy in a sandy hydraulic fill is presented. The feasibility of this technique to ensure the stability of the caisson workshop and to minimize the risk of liquefaction during manufacture. This Article is interested to establish diagnostic of dynamic compaction test, basing on the results of SPT tests and quality control as well as the details of work of compaction and the properties of filling materials. A theory of soil response to a high-energy impact during dynamic compaction is proposed.

  5. Comparison of the Osteogenic Potential of Mineral Trioxide Aggregate and Endosequence Root Repair Material in a 3-dimensional Culture System.

    Science.gov (United States)

    Rifaey, Hisham S; Villa, Max; Zhu, Qiang; Wang, Yu-Hsiung; Safavi, Kamran; Chen, I-Ping

    2016-05-01

    The ability to promote osteoblast differentiation is a desirable property of root-end filling materials. Several in vitro studies compare the cytotoxicity and physical properties between mineral trioxide aggregate (MTA) and Endosequence root repair material (ERRM), but not their osteogenic potential. Three-dimensional cultures allow cells to better maintain their physiological morphology and better resemble in vivo cellular response than 2-dimensional cultures. Here we examined the osteogenic potential of MTA and ERRM by using a commercially available 3-dimensional Alvetex scaffold. Mandibular osteoblasts were derived from 3-week-old male transgenic reporter mice where mature osteoblasts express green fluorescent protein (GFP) driven by a 2.3-kilobase type I collagen promoter (Col(I)-2.3). Mandibular osteoblasts were grown on Alvetex in direct contact with MTA, ERRM, or no material (negative control) for 14 days. Osteoblast differentiation was evaluated by expression levels of osteogenic genes by using quantitative polymerase chain reaction and by the spatial dynamics of Col(I)-2.3 GFP-positive mature osteoblasts within the Alvetex scaffolds by using 2-photon microscopy. ERRM significantly increased alkaline phosphatase (Alp) and bone sialoprotein (Bsp) expression compared with MTA and negative control groups. Both MTA and ERRM increased osterix (Osx) mRNA significantly compared with the negative control group. The percentage of Col(I)-2.3 GFP-positive cells over total cells within Alvetex was the highest in the ERRM group, followed by MTA and by negative controls. ERRM promotes osteoblast differentiation better than MTA and controls with no material in a 3-dimensional culture system. Alvetex scaffolds can be used to test endodontic materials. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  6. Review of fill mining technology in Canada

    Energy Technology Data Exchange (ETDEWEB)

    Singh, K. H.; Hedley, D. G.F.

    1980-05-15

    The Canadian mining industry has a long history of being in the fore-front in developing new technology in underground hardrock mines. Examples include the development of hydraulic and cemented fills, undercut-and-fill, mechanized cut-and-fill, post pillar, vertical retreat and blasthole mining methods. The evolution of this technology is briefly described in an historical review. Backfill serves many functions, although it is generally considered in terms of its support capabilities. These functions, mainly related to the mining method used, are evaluated in regard to regional support, pillar support, fill roof, working floor, dilution control and waste disposal. With the advent of blasthole and vertical retreat methods for pillar recovery operations, the freestanding height of backfill walls has assumed greater importance. Consequently, more attention is being given to what fill properties are required to achieve fill wall exposures up to 25 m wide by 90 m high. With the large increases in energy costs, alternatives to partially replace Portland cement in fill are being examined. The validation of mining concepts and the interaction of backfill is perhaps best evaluated by in-situ measurements. Examples are given of stress, deformation and fill pressure measurements in longitudinal cut-and-fill, post pillar mining and blasthole stoping with delayed fill which were taken in several mines in Canada. Finally, the overall design procedure used in deciding mining method, stope and pillar dimensions, sequence of extraction, fill properties and support systems at a new mine is described.

  7. Investigating the effect of aeration powder filling on the actual compacting press; Eareto jutenho no jikki press deno hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, M. [Toyota Central Research and Development Labs., Inc., Nagoya (Japan); Urata, I. [Toyota Motor Co. Ltd., Aichi (Japan)

    1998-05-15

    The authors proposed an aeration filling method as a new filling method in order to obtain uniform and high speed filling by carrying out basic experiments on powder material filling using a visual apparatus. In this study, the aeration powder filling was applied to the product compacting on the actual compacting press, and its evaluation was carried out. As a result, the following effects were confirmed. The weight scattering was reduced to about 70% in the high speed filling and about 50% in the low speed filling. The maximum density was reduced to about 30% in the high speed filling and about 25% in the low speed filling. The maximum thickness difference was reduced to 65% in the high speed filling and about 20% in the low speed filling. The aeration powder effect was stronger in the high speed filling than that in the low speed filling. The weight and size accuracy of the components were increased by the aeration powder filling. The pause and the shaking operation were discarded in the front part of the powder box, thus the filling time could be remarkable shortened. 3 refs., 6 figs.

  8. Physico-mechanical characteristics of commercially available bulk-fill composites.

    Science.gov (United States)

    Leprince, Julian G; Palin, William M; Vanacker, Julie; Sabbagh, Joseph; Devaux, Jacques; Leloup, Gaetane

    2014-08-01

    Bulk-fill composites have emerged, arguably, as a new "class" of resin-based composites, which are claimed to enable restoration in thick layers, up to 4mm. The objective of this work was to compare, under optimal curing conditions, the physico-mechanical properties of most currently available bulk-fill composites to those of two conventional composite materials chosen as references, one highly filled and one flowable "nano-hybrid" composite. Tetric EvoCeram Bulk Fill (Ivoclar-Vivadent), Venus Bulk Fill (Heraeus-Kulzer), SDR (Dentsply), X-tra Fil (VOCO), X-tra Base (VOCO), Sonic Fill (Kerr), Filtek Bulk Fill (3M-Espe), Xenius (GC) were compared to the two reference materials. The materials were light-cured for 40s in a 2mm×2mm×25mm Teflon mould. Degree of conversion was measured by Raman spectroscopy, Elastic modulus and flexural strength were evaluated by three point bending, surface hardness using Vickers microindentation before and after 24h ethanol storage, and filler weight content by thermogravimetric analysis. The ratio of surface hardness before and after ethanol storage was considered as an evaluation of polymer softening. Data were analyzed by one-way ANOVA and post hoc Tukey's test (p=0.05). The mechanical properties of the bulk-fill composites were mostly lower compared with the conventional high viscosity material, and, at best, comparable to the conventional flowable composite. Linear correlations of the mechanical properties investigated were poor with degree of conversion (0.090.8). Softening in ethanol revealed differences in polymer network density between material types. The reduction of time and improvement of convenience associated with bulk-fill materials is a clear advantage of this particular material class. However, a compromise with mechanical properties compared with more conventional commercially-available nano-hybrid materials was demonstrated by the present work. Given the lower mechanical properties of most bulk-fill materials

  9. Characterization of Low Density Glass Filled Epoxies

    National Research Council Canada - National Science Library

    Quesenberry, Matthew

    2003-01-01

    This report discusses the experimental determination and modeling of several thermophysical and mechanical properties of glass filled epoxy composite systems for potential use as electronic potting compounds...

  10. [Evaluation of cermet fillings in abutment teeth in removable partial prostheses].

    Science.gov (United States)

    Saulic, S; Tihacek-Sojic, Lj

    2001-01-01

    The aim of the study was to describe the clinical process of setting the purpose filling on abutment teeth, after finishing the removable partial dentures. The aim was also to investigate the use of cermet glass-ionomer cement for the purpose filling in the abutment teeth for removable partial dentures, as well as to investigate the surface of the purpose filling. For the clinical evaluation of purpose filling slightly modified criteria according to Ryg's were used in 20 patients with different type of edentulousness. Changes occurring on the surface of purpose filling have been experimentally established by the method of scanning electron microscopy on the half-grown third molars in seven patients. It could be concluded that cement glass-ionomer was not the appropriate material for the purpose fillings in abutment teeth for removable partial dentures.

  11. Inactivation of Aerosolized Biological Agents using Filled Nanocomposite Materials

    Science.gov (United States)

    2013-02-01

    radiation dose absorbed) roentgen shake slug torr (mm Hg, 0 0 C) *The bacquerel (Bq) is the SI unit of radioactivity ; 1 Bq = 1 event/s...setup was made of stainless steel. The setup was assembled and operated inside a class II biosafety cabinet (Model 6TX, Baker Co., Inc., Sanford, ME...system; (ii) Effectiveness of the facility decontamination conducted between the tests; (iii) Inactivation of spores exposed to combustion of strands

  12. Market Assessment and Demonstration of Lignite FBC Ash Flowable Fill Applications

    International Nuclear Information System (INIS)

    Alan E. Bland

    2003-01-01

    Montana-Dakota Utilities (MDU) and Western Research Institute (WRI) have been developing flowable fill materials formulated using ash from the Montana-Dakota Utilities R. M. Heskett Station in Mandan, North Dakota. MDU and WRI have partnered with the U.S. Department of Energy (DOE) and the North Dakota Industrial Commission (NDIC) to further the development of these materials for lignite-fired fluidized-bed combustion (FBC) facilities. The MDU controlled density fill (CDF) appears to be a viable engineering material and environmentally safe. WRI is pursuing the commercialization of the technology under the trademark Ready-Fill(trademark). The project objectives were to: (1) assess the market in the Bismarck-Mandan area; (2) evaluate the geotechnical properties and environmental compatibility; and (3) construct and monitor demonstrations of the various grades of flowable fill products in full-scale demonstrations. The scope of initial phase of work entailed the following: Task I--Assess Market for MDU Flowable Fill Products; Task II--Assess Geotechnical and Environmental Properties of MDU Flowable Fill Products; and Task III--Demonstrate and Monitor MDU Flowable Fill Products in Field-Scale Demonstrations. The results of these testing and demonstration activities proved the following: (1) The market assessment indicated that a market exists in the Bismarck-Mandan area for structural construction applications, such as sub-bases for residential and commercial businesses, and excavatable fill applications, such as gas line and utility trench filling. (2) The cost of the MDU flowable fill product must be lower than the current $35-$45/cubic yard price if it is to become a common construction material. Formulations using MDU ash and lower-cost sand alternatives offer that opportunity. An estimated market of 10,000 cubic yards of MDU flowable fill products could be realized if prices could be made competitive. (3) The geotechnical properties of the MDU ash-based flowable

  13. Market Assessment and Demonstration of Lignite FBC Ash Flowable Fill Applications

    Energy Technology Data Exchange (ETDEWEB)

    Alan E. Bland

    2003-09-30

    Montana-Dakota Utilities (MDU) and Western Research Institute (WRI) have been developing flowable fill materials formulated using ash from the Montana-Dakota Utilities R. M. Heskett Station in Mandan, North Dakota. MDU and WRI have partnered with the U.S. Department of Energy (DOE) and the North Dakota Industrial Commission (NDIC) to further the development of these materials for lignite-fired fluidized-bed combustion (FBC) facilities. The MDU controlled density fill (CDF) appears to be a viable engineering material and environmentally safe. WRI is pursuing the commercialization of the technology under the trademark Ready-Fill{trademark}. The project objectives were to: (1) assess the market in the Bismarck-Mandan area; (2) evaluate the geotechnical properties and environmental compatibility; and (3) construct and monitor demonstrations of the various grades of flowable fill products in full-scale demonstrations. The scope of initial phase of work entailed the following: Task I--Assess Market for MDU Flowable Fill Products; Task II--Assess Geotechnical and Environmental Properties of MDU Flowable Fill Products; and Task III--Demonstrate and Monitor MDU Flowable Fill Products in Field-Scale Demonstrations. The results of these testing and demonstration activities proved the following: (1) The market assessment indicated that a market exists in the Bismarck-Mandan area for structural construction applications, such as sub-bases for residential and commercial businesses, and excavatable fill applications, such as gas line and utility trench filling. (2) The cost of the MDU flowable fill product must be lower than the current $35-$45/cubic yard price if it is to become a common construction material. Formulations using MDU ash and lower-cost sand alternatives offer that opportunity. An estimated market of 10,000 cubic yards of MDU flowable fill products could be realized if prices could be made competitive. (3) The geotechnical properties of the MDU ash-based flowable

  14. 7 CFR 58.730 - Filling containers.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Filling containers. 58.730 Section 58.730 Agriculture... Procedures § 58.730 Filling containers. Hot fluid cheese from the cookers may be held in hotwells or hoppers... shall effectively measure the desired amount of product into the pouch or container in a sanitary manner...

  15. Selective filling of Photonic Crystal Fibres

    DEFF Research Database (Denmark)

    Nielsen, Kristian; Noordegraaf, Danny; Sørensen, Thorkild

    2005-01-01

    A model for calculating the time necessary for filling one or more specific holes in a photonic crystal fibre is made. This model is verified for water, and its enabling potential is illustrated by a polymer application. Selective filling of the core in an air-guide photonic crystal fibre...

  16. Thermal conductivity and stability of nano size carbon black filled PDMS: Fuel cell perspective

    CSIR Research Space (South Africa)

    Chen, H

    2011-01-01

    Full Text Available Carbon black filled Polydimethylsiloxane (PDMS) was considered as a prospective bipolar plate material candidate for a Fuel Cell. In this perspective, thermal conductivity and stability of the composites were investigated. Samples with filler weight...

  17. Impact testing of polymer-filled auxetics using Split Hopkinson Pressure Bar

    Czech Academy of Sciences Publication Activity Database

    Fíla, T.; Zlámal, P.; Jiroušek, O.; Falta, J.; Koudelka_ml., P.; Kytýř, D.; Doktor, T.; Valach, Jaroslav

    2017-01-01

    Roč. 19, č. 10 (2017), č. článku 1700076. ISSN 1438-1656 R&D Projects: GA MŠk(CZ) LO1219 Keywords : bridge decks * filled polymers * filling * honeycomb structures * impact testing * mechanical testing * Poisson ratio * polyurethanes Subject RIV: JJ - Other Materials OBOR OECD: Materials engineering Impact factor: 2.319, year: 2016 http://onlinelibrary.wiley.com/doi/10.1002/adem.201700076/abstract

  18. Biopharmaceutical formulations for pre-filled delivery devices.

    Science.gov (United States)

    Jezek, Jan; Darton, Nicholas J; Derham, Barry K; Royle, Nikki; Simpson, Iain

    2013-06-01

    Pre-filled syringes are becoming an increasingly popular format for delivering biotherapeutics conveniently and cost effectively. The device design and stable liquid formulations required to enable this pre-filled syringe format are technically challenging. In choosing the materials and process conditions to fabricate the syringe unit, their compatibility with the biotherapeutic needs to be carefully assessed. The biothereaputic stability demanded for the production of syringe-compatible low-viscosity liquid solutions requires critical excipient choices to be made. The purpose of this review is to discuss key issues related to the stability aspects of biotherapeutics in pre-filled devices. This includes effects on both physical and chemical stability due to a number of stress conditions the product is subjected to, as well as interactions with the packaging system. Particular attention is paid to the control of stability by formulation. We anticipate that there will be a significant move towards polymer primary packaging for most drugs in the longer term. The timescales for this will depend on a number of factors and hence will be hard to predict. Formulation will play a critical role in developing successful products in the pre-filled syringe format, particularly with the trend towards concentrated biotherapeutics. Development of novel, smart formulation technologies will, therefore, be increasingly important.

  19. Text-Filled Stacked Area Graphs

    DEFF Research Database (Denmark)

    Kraus, Martin

    2011-01-01

    -filled stacked area graphs; i.e., graphs that feature stacked areas that are filled with small-typed text. Since these graphs allow for computing the text layout automatically, it is possible to include large amounts of textual detail with very little effort. We discuss the most important challenges and some...... solutions for the design of text-filled stacked area graphs with the help of an exemplary visualization of the genres, publication years, and titles of a database of several thousand PC games....

  20. Droplet Measurement below Single-Layer Grid Fill

    Directory of Open Access Journals (Sweden)

    Vitkovic Pavol

    2016-01-01

    Full Text Available The main part of the heat transfer in a cooling tower is in a fill zone. This one is consist of a cooling fill. For the cooling tower is used a film fill or grid fill or splash fill in the generally. The grid fill has lower heat transfer performance like film fill usually. But their advantage is high resistance to blockage of the fill. The grid fill is consisted with independent layers made from plastic usually. The layers consist of several bars connected to the different shapes. For experiment was used the rhombus shape. The drops diameter was measured above and below the Grid fill.

  1. Potential of scrap tire rubber as lightweight aggregate in flowable fill.

    Science.gov (United States)

    Pierce, C E; Blackwell, M C

    2003-01-01

    Flowable fill is a self-leveling and self-compacting material that is rapidly gaining acceptance and application in construction, particularly in transportation and utility earthworks. When mixed with concrete sand, standard flowable fill produces a mass density ranging from 1.8 to 2.3 g/cm(3) (115-145 pcf). Scrap tires can be granulated to produce crumb rubber, which has a granular texture and ranges in size from very fine powder to coarse sand-sized particles. Due to its low specific gravity, crumb rubber can be considered a lightweight aggregate. This paper describes an experimental study on replacing sand with crumb rubber in flowable fill to produce a lightweight material. To assess the technical feasibility of using crumb rubber, the fluid- and hardened-state properties of nine flowable fill mixtures were measured. Mixture proportions were varied to investigate the effects of water-to-cement ratio and crumb rubber content on fill properties. Experimental results indicate that crumb rubber can be successfully used to produce a lightweight flowable fill (1.2-1.6 g/cm(3) [73-98 pcf]) with excavatable 28-day compressive strengths ranging from 269 to 1194 kPa (39-173 psi). Using a lightweight fill reduces the applied stress on underlying soils, thereby reducing the potential for bearing capacity failure and minimizing soil settlement. Based on these results, a crumb rubber-based flowable fill can be used in a substantial number of construction applications, such as bridge abutment fills, trench fills, and foundation support fills.

  2. Water sorption and solubility of bulk-fill composites polymerized with a third generation LED LCU

    Directory of Open Access Journals (Sweden)

    Tuğba MİSİLLİ

    2017-10-01

    Full Text Available Abstract The aim of this study was to compare the degree of water sorption and solubility in bulk-fills after curing with a polywave light source. A total of 120 disc-shaped specimens (8 mm diameter; 4 mm depth were prepared from three regular bulk-fill materials (X-tra Fil, Tetric N-Ceram Bulk Fill, SonicFill, and a control material (Filtek Z250, cured in 3 different modes (standard: 1000 mW/cm2-20 s; high power: 1400 mW/cm2-12 s; xtra power: 3200 mW/cm2-6 s using a third generation light-emitting diode light curing unit. Water sorption and solubility levels of the specimens were measured according to the ISO 4049:2009 specification after storing in distilled water for 30 days. Data were analyzed using two-way ANOVA and Tukey’s post-hoc test (p < 0.05. The Z250 sample exposed to high power presented a higher sorption compared to the X-tra Fil and SonicFill samples. In xtra power mode, the values of Z250 and SonicFill were similar to each other and higher compared to those of X-tra Fil. Only SonicFill exhibited significantly different sorption values depending on the curing mode, the highest of which was achieved when using the xtra power mode. The highest solubility values were obtained for SonicFill. No statistically significant differences were found among other groups. No significant correlation was detected between water sorption and solubility. The traditional composite group exhibited a higher water sorption values than the bulk-fills. The reduction in polymerization time significantly increased the sorption of SonicFill. SonicFill showed the highest water solubility value among the composites tested.

  3. Flexible walled container having membrane fitment for use with aseptic filling apparatus

    International Nuclear Information System (INIS)

    Davis, J.C.; Reiss, R.J.; Rica, A.F.

    1984-01-01

    There is disclosed an aseptic flexible walled container having a rigid fitment member cooperative with an aseptic filling apparatus and including a neck, outer flanges surrounding the neck, a frangible membrane and an outer end rim receptive of an hermetically sealed lid. The neck is formed with an internal chamferred seating shoulder for fluid-tight engagement with a fill tube. One outer flange cooperates with clamping jaws of the aseptic filling apparatus for detachably sealing the fitment to a sterilizing chamber and placing it in position for insertion of the filling tube which ruptures the membrane and permits the aseptic introduction of product to the container's interior. The other outer flange is secured to an opening in a wall of the flexible container. The joined fitment and container are presterilized prior to filling. Selected materials for the multi-ply container walls and the fitment permit the container to withstand gamma ray and other sterilization treatment, heat and pressure while maintaining required strength. After the container is aseptically filled, such as with flowable food product, the fill tube is withdrawn and a lid is hermetically sealed onto the rim of the fitment. A heat shield adjacent a container wall surrounds the fitment to protect the container from excessive heat generated by the associated filling apparatus during filling

  4. The screen character of the Whitetiger mountain filling to radioactivity waste disposal

    International Nuclear Information System (INIS)

    Shi Jianfang

    2003-01-01

    Safety disposal of radioactivity waste depends on geology protective screen and artificial protective screen. After disposal site is chosen, the effect of artificial protective screen appears very important. The smashing material of Whitetiger Mountain clay rock is selected as researching object. The method of combining soil mechanics with radiochemistry is adopted on the basis of many experiment of laboratory. The screen effect and mechanism of filling layer to radioactivity nuclide 90 Sr are discussed. Under the circumstance of filling layer composition, control effect of soil body construction to permeability and adsorption of filling protective screen layer are analysed. Synthesis evaluation model of filling protective screen layer is established. It is found that the filling belongs to high-liquids-clay. For filling with diameter equal or smaller than 2 millimeter, when the ρ d equal 1.73 g/cm 3 , the most equitable moving speed of 90 Sr in compaction filling is 4.5 x 10 -5 cm/min, the k equals 2.68 x10 -8 cm/s. For filling with diameter equal or smaller than 5 mm, when the ρ d equal 1.74 g/cm 3 , the most equitable moving speed of 90 Sr in compaction filling is 4.3 x 10 -5 cm/min, the k equals 6.1 x 10 -8 cm/s. (author)

  5. Thermal, spectral, and surface properties of LED light-polymerized bulk fill resin composites.

    Science.gov (United States)

    Pişkin, Mehmet Burçin; Atalı, Pınar Yılmaz; Figen, Aysel Kantürk

    2015-02-01

    The aim of this study was to evaluate the thermal, spectral, and surface properties of four different bulk fill materials – SureFil SDR (SDR, Dentsplay DETREY), QuixFil (QF, Dentsplay DETREY), X-tra base (XB, Voco) X-tra fil (XF, Voco) – polymerized by light-emitting diode (LED). Resin matrix, filler type, size and amount, and photoinitiator types influence the degree of conversion. LED-cured bulk fill composites achieved sufficient polymerization. Scanning electron microscope (SEM) analysis revealed different patterns of surface roughness, depending on the composite material. Bulk fill materials showed surface characteristics similar to those of nanohybrid composites. Based on the thermal analysis results, glass transition (T(g)) and initial degradation (T(i)) temperatures changed depending on the bulk fill resin composites.

  6. PERVAPORATION USING ADSORBENT-FILLED MEMBRANES

    Science.gov (United States)

    Membranes containing selective fillers, such as zeolites and activated carbon, can improve the separation by pervaporation. Applications of adsorbent-filled membranes in pervaporation have been demonstrated by a number of studies. These applications include removal of organic co...

  7. Microtensile bond strength of bulk-fill restorative composites to dentin.

    Science.gov (United States)

    Mandava, Jyothi; Vegesna, Divya-Prasanna; Ravi, Ravichandra; Boddeda, Mohan-Rao; Uppalapati, Lakshman-Varma; Ghazanfaruddin, M D

    2017-08-01

    To facilitate the easier placement of direct resin composite in deeper cavities, bulk fill composites have been introduced. The Mechanical stability of fillings in stress bearing areas restored with bulk-fill resin composites is still open to question, since long term clinical studies are not available so far. Thus, the objective of the study was to evaluate and compare the microtensile bond strength of three bulk-fill restorative composites with a nanohybrid composite. Class I cavities were prepared on sixty extracted mandibular molars. Teeth were divided into 4 groups (n= 15 each) and in group I, the prepared cavities were restored with nanohybrid (Filtek Z250 XT) restorative composite in an incremental manner. In group II, III and IV, the bulk-fill composites (Filtek, Tetric EvoCeram, X-tra fil bulk-fill restoratives) were placed as a 4 mm single increment and light cured. The restored teeth were subjected to thermocycling and bond strength testing was done using instron testing machine. The mode of failure was assessed by scanning electron microscope (SEM). The bond strength values obtained in megapascals (MPa) were subjected to statistical analysis, using SPSS/PC version 20 software.One-way ANOVA was used for groupwise comparison of the bond strength. Tukey's Post Hoc test was used for pairwise comparisons among the groups. The highest mean bond strength was achieved with Filtek bulk-fill restorative showing statistically significant difference with Tetric EvoCeram bulk-fill ( p composites. Adhesive failures are mostly observed with X-tra fil bulk fill composites, whereas mixed failures are more common with other bulk fill composites. Bulk-fill composites exhibited adequate bond strength to dentin and can be considered as restorative material of choice in posterior stress bearing areas. Key words: Bond strength, Bulk-fill restoratives, Configuration factor, Polymerization shrinkage.

  8. Relationships between the climate change and the grain filling of winter wheat

    International Nuclear Information System (INIS)

    Shang, Z.; Jiang, D.

    2016-01-01

    The present study is based on the material in a grain filling rate experiment of winter wheat and hourly weather data organised by Xinghua city of Jiangsu Province. The aims are to objectively evaluate the possible influences of the temperature, precipitation, sunshine at the different time of the same day on the grain filling rate of winter wheat. The grain filling rate evaluation model of climate change is firstly developed, and then, the model calculation results are compared with the observed data. The along the changes of the microclimate, changes of the grain filling rate of winter wheat, which is not same in the gradual, rapid and slow increase stages. The changes in grain filling rate of winter wheat, which were caused by variations of temperature, precipitation and sunshine duration, showed periodic fluctuation. Variation in temperature resulted in 1.36 g d/sup -1/(10a)/sup -1/ of grain filling rate change; variation in precipitation resulted in -1.35 g d/sup -1/. (10a)/sup -1/ of grain filling rate change; and variation in sunshine duration resulted in 0.07 g d/sup -1/ (10a)/sup -1/ of grain filling rate change. Three samples showed a grain filling rate change of 0.08 g d/sup -1/(10a)/sup -1/. These findings indicate that the increase in temperature and sunshine duration caused the elevation of grain filling rate, whereas the increase in precipitation decreased the grain filling rate. Therefore, monitoring and predication capability of Meteorological disasters, such as drought caused by high temperature, should be strengthened to ensure the favourable weather condition and improve the grain filling rate through scientific methods such as artificial precipitation. (author)

  9. Dural sinus filling defect: intrasigmoid encephalocele

    Science.gov (United States)

    Karatag, Ozan; Cosar, Murat; Kizildag, Betul; Sen, Halil Murat

    2013-01-01

    Filling defects of dural venous sinuses are considered to be a challenging problem especially in case of symptomatic patients. Many lesions have to be ruled out such as sinus thrombosis, arachnoid granulations and tumours. Encephalocele into dural sinus is also a rare cause of these filling defects of dural sinuses. Here, we report an extremely rare case with spontaneous occult invagination of temporal brain tissue into the left sigmoid sinus and accompanying cerebellar ectopia. PMID:24311424

  10. 129 Xe-NMR of carbon black filled elastomers

    International Nuclear Information System (INIS)

    Sperling-Ischinsky, K.; Veeman, W.S.

    1999-01-01

    It is shown that 129 Xe-NMR is a powerful tool to investigate carbon black and carbon black filled elastomers. For the carbon black material itself the 129 Xe chemical shift of xenon adsorbed at the surface of carbon black aggregates yields information about the relative average pore size of the carbon black aggregates. The experimental 129 Xe-NMR results of carbon black filled ethylene-propylene-diene (EPDM) can be explained when it is assumed that the xenon atoms in the bound EPDM fraction exchange rapidly on the NMR time scale between a state where they are adsorbed on the carbon black surface and a state in which they are absorbed in the EPDM layer. This would imply that the carbon black aggregates are not completely covered with EPDM chains. (author)

  11. Security of bottle to fill in a high pressure air

    Science.gov (United States)

    Todic, M.; Latinovic, T.; Golubovic-Bugarski, V.; Majstorovic, A.

    2018-01-01

    Charging the bottle of high pressure air isolation devices is performed by a high-pressure compressor. The charging time is in function of the compressor capacity and the intensity of the nominal pressure of the air in the bottle. However, in accident situations this time is long and therefore high-pressure accumulators are used where the filling time of the bottle of isolation apparatus has been drastically reduced. Due to the short filling time of the bottle through the air flow, there is a thermodynamic load of bottle material that could endanger the safety of users and other participants in the area. It is therefore necessary to determine the critical parameters of the rapid charge and their intensity.

  12. A comparative study of bulk-fill composites: degree of conversion, post-gel shrinkage and cytotoxicity

    Directory of Open Access Journals (Sweden)

    Flávia Gonçalves

    2018-03-01

    Full Text Available Abstract: Bulk-fill composites are claimed to be restorative materials used in deep preparations and effectively photoactivated in layers up to 4 mm. The aim of the present study was to evaluate the degree of conversion, post-gel volumetric shrinkage, and cytotoxicity of six bulk-fill and two conventional composites. Degree of conversion was determined by FTIR spectroscopy; post-gel volumetric shrinkage was determined using the strain gauge method; and cytotoxicity in human fibroblasts was evaluated indirectly by the MTT assay. Data were subjected to one-way ANOVA/Tukey's test (α = 0.05. All materials, including bulk-fill and conventional composites, were classified as non-toxic, with cell viability higher than 70%. Bulk-fill composites exhibited volumetric shrinkage similar to or lower (1.4 to 0.4% than that of conventional composites (1.7–2.1%. However, only four of the bulk-fill composites were able to sustain a homogeneous conversion at the 4-mm depth. Despite their non-toxicity and shrinkage similar to that of conventional materials, not all commercial bulk-fill materials were able to maintain a conversion as high as 80% of the superficial layer, at the 4-mm depth, indicating some failure in the bulk-fill design of some commercial brands. Therefore, the use of bulk-fill materials in dental practice is advantageous, but special attention should be given to the selection and correct use of the materials.

  13. Measuring the fill height of sealed cans with a compound pendulum

    International Nuclear Information System (INIS)

    Rinard, P.M.

    1995-06-01

    A compound pendulum has been designed, fabricated, tested, and used to determine the fill height of material in sealed cans. The specific cans that stimulated this work are partially filled with uranium and plutonium oxide. Fill height affects nondestructive assays using fission neutrons, but corrections for various fill heights can be made once the height is known. Heights vary with use as the powder compacts or loosens, so it is necessary to determine the height at the time of the neutron measurement. The pendulum is small and readily portable so it can be taken to the location of the neutron measurement. Tests with open cans filled with sand to various known heights had accuracies generally within 3%. Factors that can affect the accuracy are examined and discussed. Experience in using the pendulum on sealed cans is related

  14. Assessment of periapical health, quality of root canal filling, and ...

    African Journals Online (AJOL)

    Sixty three teeth were found to have short root canal fillings, whereas 74 teeth had adequate root canal fillings, and the remaining 10 teeth had over extended root canal filling. A significant correlation was observed between the length of root filling and apical periodontitis (P = 0,023). Inadequately dense root canal filling was ...

  15. Soil and minespoil fill as media for renovation of nitrogen and phosphorus in domestic wastewater

    International Nuclear Information System (INIS)

    Peterson, C.E.; Reneau, R.B. Jr.; Hagedorn, C.

    1998-01-01

    Development of US Appalachian coal mining regions has been hampered by lack of domestic waste disposal technologies suited to fills. The suitability of on-site wastewater treatment and disposal systems (OSWTDS) in fill material is uncertain due to the effects of surface mining on soil physical properties. This research evaluated the potential for renovation of N and P present in domestic wastewater by fills from mining operations. N and P were chosen because of their potential adverse environmental impacts. Soil-fill (a mixture of Jefferson, fine-loamy, siliceous, mesic Typic Hapludult and Muskingom, fine-loamy, mixed, mesic Typic Dystrochrept soils) and minespoil (spoil)-fill (blasted rock material associated with the Taggart Marker and Low Splint Bench coal seams of the Upper Middle Wise Formation) were used. Septic tank effluent (STE) and sand filter effluent (SFE) were applied to spoil-fill columns at four loading rates and spoil-fill columns at one loading rate for a period of 20 wk. Renovation of wastewater was assessed by determining the concentration of N and P present in column leachate. Reduction of inorganic N(NO 3 - + NH 4 + ), based on N/Cl ratios ranged from 14.9 to 32.1% after the varying application rates of STE and SFE passed through the soil columns. However, leachate NO 3 - -N concentrations were still above the 10 mg -1 drinking water standard. The quantity of P emerging from the spoil-fill columns (3.0 mg PL -1 ) was higher than anticipated and may be related to the indigenous P present in the minespoil. Sorption of P in the spoil-fill column decreased with increased STE and SFE application (reduction ranged from 99.1 to 74.4%). Results from this study indicate that there is potential for renovating wastewater in OSWTDS in selected soil-fill areas in reclaimed minelands. 33 refs., 2 figs., 4 tabs

  16. NSLS-II filling pattern measurement

    International Nuclear Information System (INIS)

    Yong Hu; Dalesio, L.B.; Kiman Ha; Pinayev, I.

    2012-01-01

    Multi-bunch injection will be deployed at NSLS-II. High bandwidth diagnostic beam monitors with high speed digitizers are used to measure bunch-by-bunch charge variation. In order to minimize intensity-correlated orbit oscillations due to uneven bunch patterns, we need to measure the filling pattern (also named bunch pattern or bunch structure). This paper focuses on filling pattern measurements: how to measure bunch structure and make this information available in EPICS-based control system. This measurement requires combination of 3 types of beam monitors (Wall Current Monitor, Fast Current Transformer and Beam Position Monitor), data acquisition and controls (fast digitizer, EPICS software, etc.) and Event Timing system. High-bandwidth filling pattern monitor requires high-speed digitizer to sample its analog output signal. The evaluation results of commercial fast digitizer Agilent Acqiris and high bandwidth detector Bergoz FCT are presented. We have also tested the algorithm software for filling pattern measurement as well as the interface to event timing system. It appears that filling pattern measurement system is well understood and the tests for control hardware and software have given good results

  17. Strength of biodegradable polypropylene tapes filled with a modified starch

    Science.gov (United States)

    Vinidiktova, N. S.; Ermolovich, O. A.; Goldade, V. A.; Pinchuk, L. S.

    2006-05-01

    The possibility of creating composite materials with high deformation and strength characteristics based on polypropylene (PP) and a natural polysaccharide in the form of a modified starch (MS) has been studied. The modified starch is shown to interact chemically with functional groups of PP, thereby positively affecting the physicomechanical properties, structure, and water absorption properties of films and oriented flat fibers based on starch-filled PP. The strength characteristics of both oriented and unoriented composites are 1.5-2.0 times as high as those of the initial PP. The water absorption ability of the materials varies symbatically with content of MS, which points to the dominant contribution of interactions at the PP-MS interface. The introduction of MS into synthetic polymers offers a possibility of producing new ecologically safe materials with high strength characteristics.

  18. One-dimensional Gromov minimal filling problem

    International Nuclear Information System (INIS)

    Ivanov, Alexandr O; Tuzhilin, Alexey A

    2012-01-01

    The paper is devoted to a new branch in the theory of one-dimensional variational problems with branching extremals, the investigation of one-dimensional minimal fillings introduced by the authors. On the one hand, this problem is a one-dimensional version of a generalization of Gromov's minimal fillings problem to the case of stratified manifolds. On the other hand, this problem is interesting in itself and also can be considered as a generalization of another classical problem, the Steiner problem on the construction of a shortest network connecting a given set of terminals. Besides the statement of the problem, we discuss several properties of the minimal fillings and state several conjectures. Bibliography: 38 titles.

  19. Development and Substantiation of Parameters of Environmentally Friendly Technology for Filling the Vertical Mine Workings with Autoclaved Slag-Concrete

    Directory of Open Access Journals (Sweden)

    Uglyanitca Andrey

    2017-01-01

    Full Text Available The environmentally friendly technology for filling the vertical mine workings with autoclaved slag-concrete, prefabricated on the surface of the mine is presented in the article; the optimal parameters of filling technology are proposed. The developed technology for filling the abandoned vertical mine workings allows ensuring the environmental safety of the territories adjacent to the abandoned mine, utilizing slag dumps and providing the possibility of shaft recovery, if necessary, with minimal labor and material costs.

  20. Burrowing inhibition by fine textured beach fill: Implications for recovery of beach ecosystems

    Science.gov (United States)

    Viola, Sloane M.; Hubbard, David M.; Dugan, Jenifer E.; Schooler, Nicholas K.

    2014-10-01

    Beach nourishment is often considered the most environmentally sound method of maintaining eroding shorelines. However, the ecological consequences are poorly understood. Fill activities cause intense disturbance and high mortality and have the potential to alter the diversity, abundance, and distribution of intertidal macroinvertebrates for months to years. Ecological recovery following fill activities depends on successful recolonization and recruitment of the entire sandy intertidal community. The use of incompatible sediments as fill material can strongly affect ecosystem recovery. We hypothesized that burrowing inhibition of intertidal animals by incompatible fine fill sediments contributes to ecological impacts and limits recovery in beach ecosystems. We experimentally investigated the influence of intertidal zone and burrowing mode on responses of beach invertebrates to altered sediment texture (28-38% fines), and ultimately the potential for colonization and recovery of beaches disturbed by beach filling. Using experimental trials in fill material and natural beach sand, we found that the mismatched fine fill sediments significantly inhibited burrowing of characteristic species from all intertidal zones, including sand crabs, clams, polychaetes, isopods, and talitrid amphipods. Burrowing performance of all five species we tested was consistently reduced in the fill material and burrowing was completely inhibited for several species. The threshold for burrowing inhibition by fine sediment content in middle and lower beach macroinvertebrates varied by species, with highest sensitivity for the polychaete (4% fines, below the USA regulatory limit of 10% fines), followed by sand crabs and clams (20% fines). These results suggest broader investigation of thresholds for burrowing inhibition in fine fill material is needed for beach animals. Burrowing inhibition caused by mismatched fill sediments exposes beach macroinvertebrates to stresses, which could depress

  1. Toughening Mechanisms in Silica-Filled Epoxy Nanocomposites

    Science.gov (United States)

    Patel, Binay S.

    Epoxies are widely used as underfill resins throughout the microelectronics industry to mechanically couple and protect various components of flip-chip assemblies. Generally rigid materials largely surround underfill resins. Improving the mechanical and thermal properties of epoxy resins to better match those of their rigid counterparts can help extend the service lifetime of flip-chip assemblies. Recently, researchers have demonstrated that silica nanoparticles are effective toughening agents for lightly-crosslinked epoxies. Improvements in the fracture toughness of silica-filled epoxy nanocomposites have primarily been attributed to two toughening mechanisms: particle debonding with subsequent void growth and matrix shear banding. Various attempts have been made to model the contribution of these toughening mechanisms to the overall fracture energy observed in silica-filled epoxy nanocomposites. However, disparities still exist between experimental and modeled fracture energy results. In this dissertation, the thermal, rheological and mechanical behavior of eight different types of silica-filled epoxy nanocomposites was investigated. Each nanocomposite consisted of up to 10 vol% of silica nanoparticles with particle sizes ranging from 20 nm to 200 nm, with a variety of surface treatments and particle structures. Fractographical analysis was conducted with new experimental approaches in order to accurately identify morphological evidence for each proposed toughening mechanism. Overall, three major insights into the fracture behavior of real world silica-filled epoxy nanocomposites were established. First, microcracking was observed as an essential toughening mechanism in silica-filled epoxy nanocomposites. Microcracking was observed on the surface and subsurface of fractured samples in each type of silica-filled epoxy nanocomposite. The additional toughening contribution of microcracking to overall fracture energy yielded excellent agreement between experimental

  2. Posterior bulk-filled resin composite restorations.

    DEFF Research Database (Denmark)

    van Dijken, Jan WV; Pallesen, Ulla

    2016-01-01

    up to 4mm as needed to fill the cavity 2mm short of the occlusal cavosurface. The occlusal part was completed with the nano-hybrid resin composite (Ceram X mono+). In the other cavity, the resin composite-only (Ceram X mono+) was placed in 2mm increments. The restorations were evaluated using...... Class II, 4 SDR-CeramX mono+ and 6 CeramXmono+-only restorations. The main reasons for failurewere tooth fracture (6) and secondary caries (4). The annual failure rate (AFR) for all restorations (Class I and II) was for the bulk-filled-1.1% and for the resin composite-only restorations 1...

  3. Application of mathematical planning in production of filled emulsion rubbers

    Science.gov (United States)

    Pugacheva, I. N.; Molokanova, L. V.; Popova, L. V.; Repin, P. S.

    2018-05-01

    The applicability of mathematical planning of experiment in the field of chemistry and chemical engineering, in particular in the industrial production of synthetic rubbers, is considered in the article. Possibility of using secondary material resources, which are waste products of light industry, in the production of elastomeric compositions is studied. The method of obtaining a powdered cellulose additive from wastes containing cellulose fiber is described. The best way of introducing the obtained additive into elastomeric compositions based on the emulsion rubber is established. Optimal conditions for obtaining filled emulsion rubber with the help of a powdered cellulose additive were established basing on the mathematical planning of experiment.

  4. The structure of filled skutterudites and the local vibration behavior of the filling atom

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Xiaojuan [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Dongguan Institute of Neutron Science, Dongguan 523808 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Zong, Peng-an [State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Chen, Xihong [Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Tao, Juzhou, E-mail: taoj@ihep.ac.cn [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Dongguan Institute of Neutron Science, Dongguan 523808 (China); Lin, He, E-mail: linhe@sinap.ac.cn [Shanghai Institute of Applied Physics, Chinese Academy of Science, Shanghai 201204 (China)

    2017-02-15

    Both of atomic pair distribution function (PDF) and extended x-ray absorption fine structure (EXAFS) experiments have been carried out on unfilled and Yb-filled skutterudites Yb{sub x}Co{sub 4}Sb{sub 12} (x=0, 0.15, 0.2 and 0.25) samples. The structure refinements on PDF data confirm the large amplitude vibration of Yb atom and the dependence of Yb vibration amplitude on the filling content. Temperature dependent EXAFS experiment on filled skutterudites have been carried out at Yb L{sub Ⅲ}-edge in order to explore the local vibration behavior of filled atom. EXAFS experiments show that the Einstein temperature of the filled atom is very low (70.9 K) which agrees with the rattling behavior.

  5. Application of isotope tracer technique on the study of the filling and release behavior of carbon nanotubes

    International Nuclear Information System (INIS)

    Wu Shengwei; Guo Jinxue; Li Yan; Li Yulan; Li Wenxin; Liu Shiyuan

    2004-01-01

    The behaviors of washing and release of 110 Ag m -AgNO 3 from carbon nanotubes (CNTs), following soak of opened CNTs in 110 Ag m -AgNO 3 solutions are investigated with the isotope tracer technique. The filled CNTs samples are characterized by HREM, SEM, XRD and EDS. The amount of filled materials is also estimated by the isotope tracer technique. It shows that there are silver materials filled in the CNTs and would not release from the cavities. The results indicate that radioactive tracer is an effective and powerful technique to be applied into study of filling and release behaviors of CNTs as well as estimating the amount of filled materials. (authors)

  6. Form Filling with Self-Compacting Concrete

    DEFF Research Database (Denmark)

    Thrane, Lars Nyholm

    2002-01-01

    This paper describes a newly started Ph.D. project with the aim of simulating the form filling ability of Self-Compacting Concrete (SCC) taking into account the form geometry, reinforcement configuration, casting technique, and the rheological properties of the concrete. Comparative studies...

  7. Stock keeping unit fill rate specification

    NARCIS (Netherlands)

    Teunter, R. H.; Syntetos, A. A.; Babai, M. Z.

    2017-01-01

    The fill rate is the most widely applied service level measure in industry and yet there is minimal advice available on how it should be differentiated on an individual Stock Keeping Unit (SKU) basis given that there is an overall system target service level. The typical approach utilized in

  8. New Skeletal-Space-Filling Models

    Science.gov (United States)

    Clarke, Frank H.

    1977-01-01

    Describes plastic, skeletal molecular models that are color-coded and can illustrate both the conformation and overall shape of small molecules. They can also be converted to space-filling counterparts by the additions of color-coded polystyrene spheres. (MLH)

  9. Safety distances for hydrogen filling stations

    NARCIS (Netherlands)

    Matthijsen, A J C M; Kooi, E S

    2006-01-01

    In the context of spatial planning the Dutch Ministry of Housing, Spatial Planning and the Environment asked the Centre for External Safety of the National Institute for Public Health and the Environment (RIVM) to advice on safe distances pertaining to hydrogen filling stations. The RIVM made use of

  10. Banach spaces that realize minimal fillings

    International Nuclear Information System (INIS)

    Bednov, B. B.; Borodin, P. A.

    2014-01-01

    It is proved that a real Banach space realizes minimal fillings for all its finite subsets (a shortest network spanning a fixed finite subset always exists and has the minimum possible length) if and only if it is a predual of L 1 . The spaces L 1 are characterized in terms of Steiner points (medians). Bibliography: 25 titles. (paper)

  11. INS gas-filled recoil isotope separator

    International Nuclear Information System (INIS)

    Miyatake, M.; Nomura, T.; Kawakami, H.

    1986-09-01

    The characteristics and performance of a small sized gas-filled recoil isotope separator recently made at INS are described. The total efficiency and the ΔBρ/Bρ values have been measured using low velocity 16 O, 40 Ar and 68 As ions and found to be 10 and 5 %, respectively. The Z-dependence of the mean charge is discussed. (author)

  12. Stability of fruit bases and chocolate fillings

    Directory of Open Access Journals (Sweden)

    Joice Natali Miquelim

    2011-03-01

    Full Text Available Syrups with high sugar content and dehydrated fruits in its composition can be added to chocolate fillings to reduce the need of artificial flavor and dyes attributing a natural appeal to the product. Fruit bases were produced with lyophilized strawberry, passion fruit, and sliced orange peel. Rheological dynamic oscillatory tests were applied to determine the products stability and tendency of shelf life. Values of G´ G´´ were found for orange flavor during the 90 days of storage. It was observed that shear stress values did not vary significantly suggesting product stability during the studied period. For all fillings, it was found a behavior similar to the fruit base indicating that it has great influence on the filling behavior and its stability. The use of a sugar matrix in fillings provided good shelf life for the fruit base, which could be kept under room temperature conditions for a period as long as one year. The good stability and storage conditions allow the use of fruit base for handmade products as well as for industrialized products.

  13. Full-waveform inversion: Filling the gaps

    KAUST Repository

    Beydoun, Wafik B.; Alkhalifah, Tariq Ali

    2015-01-01

    After receiving an outstanding response to its inaugural workshop in 2013, SEG once again achieved great success with its 2015 SEG Middle East Workshop, “Full-waveform inversion: Filling the gaps,” which took place 30 March–1 April 2015 in Abu Dhabi

  14. A mathematical model for lake ontogeny in terms of filling with sediments and macrophyte vegetation

    International Nuclear Information System (INIS)

    Brydsten, Lars

    2004-05-01

    A mathematical model for simulation of lake basin filling processes in areas with positive shore displacement was constructed. The model was calibrated using sediment and catchments data from eight existing lake basins situated in the northern coastal area of the province of Uppland, Sweden. The lake basin filling processes were separated into three phases: basin filling with wave-washed material (silt, silty sand or sand), filling with fine-grained material during the shallow gulf and lake stages, respectively, and filling with vegetation during the lake stage. The basin filling rates for wave-washed material were generally low but varied considerably both between and within lakes. The mean basin filling rate of wave-washed material was 4.1%. The volume of inorganic sediments produced, and basin filling rates during the shallow gulf and lake phases were determined for all the eight lakes. The relationship between basin filling rate and parameters describing the catchments, the former postglacial basins and the lakes, respectively, was determined using multiple regression analysis. The basin filling rate with inorganic sediments was best described by parameters related to former postglacial basin morphometry and current lake morphometry, e.g. basin volume, lake volume, and lake area. The goodness of fit turned out to be 0.99 for a simple regression with basin volume as the sole independent variable. The basin filling with vegetation (Phragmites australis followed by Sphagnum spp.) was treated as a 2-dimensional process. A dataset with 84 bogs was selected from a digital soil map. The ages of the bogs were calculated using a digital elevation map and an equation for shore displacement. The choke-up rate was then calculated by dividing the area of the bogs with their age. A strong exponential relationship exists between areas of the bogs and choke-up rat, and this relationship was then used in the model. The resulting model starts by filling the former coastal basin

  15. A mathematical model for lake ontogeny in terms of filling with sediments and macrophyte vegetation

    Energy Technology Data Exchange (ETDEWEB)

    Brydsten, Lars [Umeaa Univ. (Sweden). Dept. of Biology and Environmental Science

    2004-05-01

    A mathematical model for simulation of lake basin filling processes in areas with positive shore displacement was constructed. The model was calibrated using sediment and catchments data from eight existing lake basins situated in the northern coastal area of the province of Uppland, Sweden. The lake basin filling processes were separated into three phases: basin filling with wave-washed material (silt, silty sand or sand), filling with fine-grained material during the shallow gulf and lake stages, respectively, and filling with vegetation during the lake stage. The basin filling rates for wave-washed material were generally low but varied considerably both between and within lakes. The mean basin filling rate of wave-washed material was 4.1%. The volume of inorganic sediments produced, and basin filling rates during the shallow gulf and lake phases were determined for all the eight lakes. The relationship between basin filling rate and parameters describing the catchments, the former postglacial basins and the lakes, respectively, was determined using multiple regression analysis. The basin filling rate with inorganic sediments was best described by parameters related to former postglacial basin morphometry and current lake morphometry, e.g. basin volume, lake volume, and lake area. The goodness of fit turned out to be 0.99 for a simple regression with basin volume as the sole independent variable. The basin filling with vegetation (Phragmites australis followed by Sphagnum spp.) was treated as a 2-dimensional process. A dataset with 84 bogs was selected from a digital soil map. The ages of the bogs were calculated using a digital elevation map and an equation for shore displacement. The choke-up rate was then calculated by dividing the area of the bogs with their age. A strong exponential relationship exists between areas of the bogs and choke-up rat, and this relationship was then used in the model. The resulting model starts by filling the former coastal basin

  16. Study of a low-dose capsule filling process by dynamic and static tests for advanced process understanding.

    Science.gov (United States)

    Stranzinger, S; Faulhammer, E; Scheibelhofer, O; Calzolari, V; Biserni, S; Paudel, A; Khinast, J G

    2018-04-05

    Precise filling of capsules with doses in the mg-range requires a good understanding of the filling process. Therefore, we investigated the various process steps of the filling process by dynamic and static mode tests. Dynamic tests refer to filling of capsules in a regular laboratory dosator filling machine. Static tests were conducted using a novel filling system developed by us. Three grades of lactose excipients were filled into size 3 capsules with different dosing chamber lengths, nozzle diameters and powder bed heights, and, in the dynamic mode, with two filling speeds (500, 3000 caps/h). The influence of the gap at the bottom of the powder container on the fill weight and variability was assessed. Different gaps resulted in a change in fill weight in all materials, although in different ways. In all cases, the fill weight of highly cohesive Lactohale 220 increased when decreasing the gap. Furthermore, experiments with the stand-alone static test tool indicated that this very challenging powder could successfully be filled without any pre-compression in the range of 5 mg-20 mg with acceptable RSDs. This finding is of great importance since for very fine lactose powders high compression ratios (dosing-chamber-length-to-powder-bed height compression ratios) may result in jamming of the piston. Moreover, it shows that the static mode setup is suitable for studying fill weight and variability. Since cohesive powders, such as Lactohale 220, are hard to fill, we investigated the impact of vibration on the process. Interestingly, we found no correlation between the reported fill weight changes in dynamic mode at 3000 cph and static mode using similar vibration. However, we could show that vibrations during sampling in the static mode dramatically reduced fill weight variability. Overall, our results indicate that by fine-tuning instrumental settings even very challenging powders can be filled with a low-dose dosator capsule filling machine. This study is a

  17. Multiscale Modeling of Dewetting Damage in Highly Filled Particulate Composites

    Science.gov (United States)

    Geubelle, P. H.; Inglis, H. M.; Kramer, J. D.; Patel, J. J.; Kumar, N. C.; Tan, H.

    2008-02-01

    Particle debonding or dewetting constitutes one of the key damage processes in highly filled particulate composites such as solid propellant and other energetic materials. To analyze this failure process, we have developed a multiscale finite element framework that combines, at the microscale, a nonlinear description of the binder response with a cohesive model of the damage process taking place in a representative periodic unit cell (PUC). To relate micro-scale damage to the macroscopic constitutive response of the material, we employ the mathematical theory of homogenization (MTH). After a description of the numerical scheme, we present the results of the damage response of a highly filled particulate composite subjected to a uniaxial macroscopic strain, and show the direct correlation between the complex damage processes taking place in the PUC and the nonlinear macroscopic constitutive response. We also present a detailed study of the PUC size and a comparison between the finite element MTH-based study and a micromechanics model of the dewetting process.

  18. The order and volume fill rates in inventory control systems

    DEFF Research Database (Denmark)

    Thorstenson, Anders; Larsen, Christian

    2011-01-01

    This paper differentiates between an order (line) fill rate and a volume fill rate and specifies their performance for different inventory control systems. When the focus is on filling complete customer orders rather than total quantities the order fill rate would be the preferred service level m...

  19. Iterative and variational homogenization methods for filled elastomers

    Science.gov (United States)

    Goudarzi, Taha

    Elastomeric composites have increasingly proved invaluable in commercial technological applications due to their unique mechanical properties, especially their ability to undergo large reversible deformation in response to a variety of stimuli (e.g., mechanical forces, electric and magnetic fields, changes in temperature). Modern advances in organic materials science have revealed that elastomeric composites hold also tremendous potential to enable new high-end technologies, especially as the next generation of sensors and actuators featured by their low cost together with their biocompatibility, and processability into arbitrary shapes. This potential calls for an in-depth investigation of the macroscopic mechanical/physical behavior of elastomeric composites directly in terms of their microscopic behavior with the objective of creating the knowledge base needed to guide their bottom-up design. The purpose of this thesis is to generate a mathematical framework to describe, explain, and predict the macroscopic nonlinear elastic behavior of filled elastomers, arguably the most prominent class of elastomeric composites, directly in terms of the behavior of their constituents --- i.e., the elastomeric matrix and the filler particles --- and their microstructure --- i.e., the content, size, shape, and spatial distribution of the filler particles. This will be accomplished via a combination of novel iterative and variational homogenization techniques capable of accounting for interphasial phenomena and finite deformations. Exact and approximate analytical solutions for the fundamental nonlinear elastic response of dilute suspensions of rigid spherical particles (either firmly bonded or bonded through finite size interphases) in Gaussian rubber are first generated. These results are in turn utilized to construct approximate solutions for the nonlinear elastic response of non-Gaussian elastomers filled with a random distribution of rigid particles (again, either firmly

  20. Characterization of subvisible particle formation during the filling pump operation of a monoclonal antibody solution.

    Science.gov (United States)

    Nayak, Arpan; Colandene, James; Bradford, Victor; Perkins, Melissa

    2011-10-01

    Characterization and control of aggregate and subvisible particle formation during fill-finish process steps are important for biopharmaceutical products. The filling step is of key importance as there is no further filtration of the drug product beyond sterile filtration. Filling processes can impact product quality by introducing physical stresses such as shear, friction, and cavitation. Other detrimental factors include temperature generated in the process of filling, foaming, and contact with filling system materials, including processing aids such as silicone oil. Certain pumps may shed extrinsic particles that may lead to heterogeneous nucleation-induced aggregation. In this work, microflow imaging, size-exclusion chromatography (SEC), and turbidimetry were utilized to quantify subvisible particles, aggregation, and opalescence, respectively. The filling process was performed using several commonly used filling systems, including rotary piston pump, rolling diaphragm pump, peristaltic pump, and time-pressure filler. The rolling diaphragm pump, peristaltic pump, and time-pressure filler generated notably less protein subvisible particles than the rotary piston pump, although no change in aggregate content by SEC was observed by any pump. An extreme increase in subvisible particles was also reflected in an increase in turbidity. Copyright © 2011 Wiley-Liss, Inc.

  1. Persistent extraradicular infection in root-filled asymptomatic human tooth: scanning electron microscopic analysis and microbial investigation after apical microsurgery.

    Science.gov (United States)

    Signoretti, Fernanda G C; Endo, Marcos S; Gomes, Brenda P F A; Montagner, Francisco; Tosello, Fernanda B; Jacinto, Rogério C

    2011-12-01

    Procedural accidents have a negative effect on healing and might contribute to the persistence of infections in inaccessible apical areas, requiring surgical intervention. This report describes a case of persistent apical periodontitis of a lower left first molar associated with the sinus tract and a periapical lesion that required nonsurgical endodontic retreatment and apical surgery for resolution. The tooth had received endodontic treatment 3 years ago and had to be retreated using the crown-down technique with chemical auxiliary substance (2% chlorhexidine gel), foramen patency, and enlargement and was filled in a single appointment. The occlusal access cavity was immediately restored with composite resin. After 1 month, it could be observed that the sinus tract persisted and, radiographically, the lesion remained unaltered. Therefore, endodontic microsurgery was indicated. Apical microsurgery was performed under magnification with the use of a dental operating microscope including apicectomy, root end with ultrasound, and sealing with mineral trioxide aggregate. A microbiological sample was collected from the apical lesion. The resected distal root apex was observed by scanning electron microscopy. The following species were detected: Actinomyces naeslundii and Actinomyces meyeri, Propionibacterium propionicum, Clostridium botullinum, Parvimonas micra, and Bacteroides ureolyticus; scanning electron microscopic analysis revealed bacterial biofilm surrounding the apical foramen and external radicular surface. Gutta-percha overfilling at the apex because of a zip caused during initial endodontic treatment could be observed. A 6-month follow-up showed apparent radiographic periapical healing, which progressed after 24 months. Gram-positive anaerobic bacteria and extraradicular biofilm seem to participate in the maintenance of persistent periapical pathology, and endodontic retreatment followed by periapical microsurgery proved to be a successful alternative in the

  2. Hugoniot-based equations of state for two filled EPDM rubbers

    Science.gov (United States)

    Pacheco, Adam; Dattelbaum, Dana; Orler, E.; Gustavsen, R.

    2013-06-01

    The shock response of silica filled and Kevlar filled ethylene-propylene-diene (EPDM) rubbers was studied using gas gun-driven plate impact experiments. Both materials are proprietary formulations made by Kirkhill-TA, Brea CA USA, and are used for ablative internal rocket motor insulation. Two types of experiments were performed. In the first, the filled-EPDM sample was mounted on the front of the projectile and impacted a Lithium Fluoride (LiF) window. The Hugoniot state was determined from the measured projectile velocity, the EPDM/LiF interface velocity (measured using VISAR) and impedance matching to LiF. In the second type of experiment, electromagnetic particle velocity gauges were embedded between layers of filled-EPDM. These provided in situ particle velocity and shock velocity measurements. Experiments covered a pressure range of 0.34 - 14 GPa. Hugoniot-based equations of state were obtained for both materials, and will be compared to those of other filled elastomers such as silica-filled polydimethylsiloxane and adiprene. Work performed while at Los Alamos National Laboratory.

  3. Flammability of Gas-Filled Polymers

    Directory of Open Access Journals (Sweden)

    Ushkov Valentin Anatol'evich

    2017-09-01

    Full Text Available The regularities of flame propagation on the horizontal surface of gas-filled polymers are considered depending on the concentration of oxygen in the oxidizer flow. The values of the coefficients in the expression describing relationship between the rate of flame propagation on the surface of foams and oxygen concentration are obtained. It was shown that with the mass content of reactive organophosphorus compounds reaching 4.0...5.9%, non-smoldering resole foam plastics with high performance characteristics are obtained. It was found that in order to obtain moderately combustible polyurethane foams based on oxyethylated phosphorus-containing polyols, the phosphorus concentration should not exceed 3 % of mass. To obtain flame-retardant urea-formaldehyde foam cellular plastics, the concentration of phosphorus should not exceed 0.3 % of mass. Physical-mechanical properties and flammability indices of developed gas-filled polymers based on reactive oligomers are presented.

  4. Form Filling with Self-Compacting Concrete

    DEFF Research Database (Denmark)

    Thrane, Lars Nyholm

    2007-01-01

    to the prospects of improving the structural quality, working environment, productivity, and architectural appearance. However, especially in vertical applications there is a great unused potential. Controlling the casting process is important in many different industries such as the metal, plastic, and food...... the framework of Computational Fluid Dynamics (CFD). CFD is applied to simulate the homogeneous form filling characteristics, i.e. the form filling ability and flow patterns, taking into account the rheological properties and casting technique. It is assumed that the rheological properties of SCC follow...... dimensions. For the heterogeneous flow phenomena, this project focusses on the assessment of blocking, which is of special interest in relation to high quality and complicated structures with a dense reinforcement configuration. A phenomenological micro-mechanical model has been developed, which introduces...

  5. Rainwater drained through fully filled pipes

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, B; Koestel, P

    1989-02-01

    The conventional rainwater drainage system according to DIN 1986 always seems to be a point of problemacy in the building services as far as the occupancy of installation shafts and ducts is at stake. The excavation work and the necessary gravity lines are considered to be expensive. The consideration of the necessary slope complicates the installation additionally. Basing on those considerations, the raindraining system with fully filled pipes has been developed. DIN 1986, edition June 1988, part 1, point 6.1.1 allows to install rainwater pipes operated as planned, fully filled without slope. An enterprise specialised in building services investigated all system laws because only by a hydraulically exact balance, the function of the rainwater drainage system operated by negative and positive pressure can be insured. The results of those investigations are integrated in a computer program developed for this purpose.

  6. Optical properties study of nano-composite filled D shape photonic crystal fibre

    Science.gov (United States)

    Udaiyakumar, R.; Mohamed Junaid, K. A.; Janani, T.; Maheswar, R.; Yupapin, P.; Amiri, I. S.

    2018-06-01

    With the nano-composite materials gaining momentum in the optical field, a new nano-composite filled D shape Photonic Crystal Fiber (PCF) is designed and the various optical properties are investigated with help of Finite Element Method. In the proposed structure the D-shape PCF is made up of silica with embedded silver nanoparticles and air holes are distributed along the fibre. The designed fibre shows various optical properties such as dispersion, birefringence, beat length and loss with respect to wavelength and compared with different filling factor like 0.1, 0.3 and 0.5. From our estimation and comparative analysis, it has been proved that the fibre loss has been decreased with increasing filling factor. Further this also showed flat dispersion at maximum filling factor.

  7. Optical properties study of nano-composite filled D shape photonic crystal fibre

    Directory of Open Access Journals (Sweden)

    R. Udaiyakumar

    2018-06-01

    Full Text Available With the nano-composite materials gaining momentum in the optical field, a new nano-composite filled D shape Photonic Crystal Fiber (PCF is designed and the various optical properties are investigated with help of Finite Element Method. In the proposed structure the D-shape PCF is made up of silica with embedded silver nanoparticles and air holes are distributed along the fibre. The designed fibre shows various optical properties such as dispersion, birefringence, beat length and loss with respect to wavelength and compared with different filling factor like 0.1, 0.3 and 0.5. From our estimation and comparative analysis, it has been proved that the fibre loss has been decreased with increasing filling factor. Further this also showed flat dispersion at maximum filling factor. Keywords: Nanoparticles, Nano-composite, Dispersion, Birefringence, Beat length

  8. Design compliance matrix waste sample container filling system for nested, fixed-depth sampling system

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    This design compliance matrix document provides specific design related functional characteristics, constraints, and requirements for the container filling system that is part of the nested, fixed-depth sampling system. This document addresses performance, external interfaces, ALARA, Authorization Basis, environmental and design code requirements for the container filling system. The container filling system will interface with the waste stream from the fluidic pumping channels of the nested, fixed-depth sampling system and will fill containers with waste that meet the Resource Conservation and Recovery Act (RCRA) criteria for waste that contains volatile and semi-volatile organic materials. The specifications for the nested, fixed-depth sampling system are described in a Level 2 Specification document (HNF-3483, Rev. 1). The basis for this design compliance matrix document is the Tank Waste Remediation System (TWRS) desk instructions for design Compliance matrix documents (PI-CP-008-00, Rev. 0)

  9. Air filled porosity in composting processes

    Energy Technology Data Exchange (ETDEWEB)

    Ruggieri, L.; Gea, T.; Artola, A.; Sanchez, A.

    2009-07-01

    As it is widely known, the composting process consists in the aerobic decomposition of the biodegradable organic matter present in different types of solid wastes. Water and oxygen are necessary for the biological activity of microorganisms involved in the composting process and their availability is directly related to the total and the air filled porosity (AFP). Maintaining adequate AFP level satisfies the oxygen content requirement to achieve the desired composting conditions and thus, tho enhance biological activity. (Author)

  10. Moon - 'Ghost' craters formed during Mare filling.

    Science.gov (United States)

    Cruikshank, D. P.; Hartmann, W. K.; Wood, C. A.

    1973-01-01

    This paper discusses formation of 'pathological' cases of crater morphology due to interaction of craters with molten lavas. Terrestrial observations of such a process are discussed. In lunar maria, a number of small impact craters (D less than 10 km) may have been covered by thin layers of fluid lavas, or formed in molten lava. Some specific lunar examples are discussed, including unusual shallow rings resembling experimental craters deformed by isostatic filling.

  11. Mobile myelographic filling defects: Spinal cysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Savoiardo, M.; Cimino, C.; Passerini, A.; La Mantia, L.

    1986-03-01

    Cysticercosis usually affects the brain and is easily demonstrated by CT. Spinal cysticercosis is much rarer and is usually diagnosed only at surgery. Myelographic demonstration of multiple rounded filling defects, some of which were mobile, allowed diagnosis of spinal extramedullary cysticercosis in an unsuspected case. The literature on spinal cysticercosis is briefly reviewed. Diagnosis is important in view of the recent development of medical treatment.

  12. The partially filled viscous ring damper.

    Science.gov (United States)

    Alfriend, K. T.

    1973-01-01

    The problem of a spinning satellite with a partially filled viscous ring damper is investigated. It is shown that there are two distinct modes of motion, the nutation-synchronous mode and spin-synchronous mode. From an approximate solution of the equations of motion a time constant is obtained for each mode. From a consideration of the fluid dynamics several methods are developed for determining the damping constant.

  13. Pulse formation of gas-filled counter

    International Nuclear Information System (INIS)

    Iwatani, Kazuo; Teshima, Kazunori; Shizuma, Kiyoshi; Hasai, Hiromi

    1991-01-01

    The pulse formation of gas-filled counter has been calculated by simple models for the proportional and self-quenching streamer (SQS) modes. Calculated pulse shapes of counter output have accurately reproduced the observed ones for both modes. As a result, it is shown that the special density distribution of ion pairs in a streamer can be estimated with the rising part of observed pulse shape, using the model. (author)

  14. Full-waveform inversion: Filling the gaps

    KAUST Repository

    Beydoun, Wafik B.

    2015-09-01

    After receiving an outstanding response to its inaugural workshop in 2013, SEG once again achieved great success with its 2015 SEG Middle East Workshop, “Full-waveform inversion: Filling the gaps,” which took place 30 March–1 April 2015 in Abu Dhabi, UAE. The workshop was organized by SEG, and its partner sponsors were Saudi Aramco (gold sponsor), ExxonMobil, and CGG. Read More: http://library.seg.org/doi/10.1190/tle34091106.1

  15. Air filled porosity in composting processes

    International Nuclear Information System (INIS)

    Ruggieri, L.; Gea, T.; Artola, A.; Sanchez, A.

    2009-01-01

    As it is widely known, the composting process consists in the aerobic decomposition of the biodegradable organic matter present in different types of solid wastes. Water and oxygen are necessary for the biological activity of microorganisms involved in the composting process and their availability is directly related to the total and the air filled porosity (AFP). Maintaining adequate AFP level satisfies the oxygen content requirement to achieve the desired composting conditions and thus, tho enhance biological activity. (Author)

  16. MORPHOLOGICAL FILLING OF DIGITAL ELEVATION MODELS

    Directory of Open Access Journals (Sweden)

    T. Krauß

    2012-09-01

    Full Text Available In this paper a new approach for a more detailed post processing and filling of digital elevation models (DEMs in urban areas is presented. To reach the required specifications in a first step the errors in digital surface models (DSMs generated by dense stereo algorithms are analyzed and methods for detection and classification of the different types of errors are implemented. Subsequently the classified erroneous areas are handled in separate manner to eliminate outliers and fill the DSM properly. The errors which can be detected in DSMs range from outliers – single pixels or small areas containing extremely high or low values – over noise from mismatches, single small holes to occlusions, where large areas are not visible in one of the images of the stereo pair. To validate the presented method artificial DSMs are generated and superimposed with all different kinds of described errors like noise (small holes cut in, outliers (small areas moved up/down, occlusions (larger areas beneath steep walls and so on. The method is subsequently applied to the artificial DSMs and the resulting filled DSMs are compared to the original artificial DSMs without the introduced errors. Also the method is applied to stereo satellite generated DSMs from the ISPRS Comission 1 WG4 benchmark dataset and the results are checked with the also provided first pulse laser DSM data. Finally the results are discussed, strengths and weaknesses of the approach are shown and suggestions for application and optimization are given.

  17. Highly filled biocomposites based on ethylene-vinyl acetate copolymer and wood flour

    Science.gov (United States)

    Shelenkov, P. G.; Pantyukhov, P. V.; Popov, A. A.

    2018-05-01

    Recently, there is a great interest in the world to biodegradable materials based on synthetic polymers in a composition with natural fillers. Highly filled polymer composite materials based on various grades of synthetic block copolymer of ethylene vinyl acetate with wood flour were under investigation. Five grades of ethylene-vinyl acetate copolymer differing in the content of vinyl acetate groups and a melt flow index were used in this work in order to find the best one for highly filled biocomposites. Wood flour content in biocomposites was 50, 60, 70 weight %. The rheological and physico-mechanical characteristics of the resulting biocomposites were studied.

  18. Insulating and sheathing materials of electric and optical cables - Common test methods - Part 5-1: Methods specific to filling compounds - Drop-point - Separation of oil - Lower temperature brittleness - Total acid number - Absence of corrosive components - Permittivity at 23 °C - DC resistivity at 23 °C and 100 °C

    CERN Document Server

    International Electrotechnical Commission. Geneva

    2004-01-01

    Specifies the test methods for filling compounds of electric cables used with telecommunication equipment. Gives the methods for drop-point, separation of oil, lower temperature brittleness, total acid number, absence of corrosive components, permittivity at 23 °C, d.c. resistivity at 23°C and 100°C.

  19. Calculation of depleted uranium concentration in dental fillings samples using the nuclear track detector CR-39

    International Nuclear Information System (INIS)

    Mahdi, K. H.; Subhi, A. T.; Tawfiq, N. F.

    2012-12-01

    The purpose of this study is to determine the concentration of depleted uranium in dental fillings samples, which were obtained some hospital and dental office, sale of materials deployed in Iraq. 8 samples were examined from two different fillings and lead-filling (amalgam) and composite filling (plastic). concentrations of depleted uranium were determined in these samples using a nuclear track detector CR-39 through the recording of the tracks left by of fragments of fission resulting from the reaction 2 38U (n, f). The samples are bombarded by neutrons emitted from the neutron source (2 41A m-Be) with flux of ( 10 5 n. cm- 2. s -1 ). The period of etching to show the track of fission fragments is 5 hours using NaOH solution with normalization (6.25N), and temperature (60 o C ). Concentration of depleted uranium were calculated by comparison with standard samples. The result that obtained showed that the value of the weighted average for concentration of uranium in the samples fillings (5.54± 1.05) ppm lead to thr filling (amalgam) and (5.33±0.6) ppm of the filling composite (plastic). The hazard- index, the absorbed dose and the effective dose for these concentration were determined. The obtained results of the effective dose for each of the surface of the bone and skin (as the areas most affected by this compensation industrial) is (0.56 mSv / y) for the batting lead (amalgam) and (0.54 mSv / y) for the filling composite (plastic). From the results of study it was that the highest rate is the effective dose to a specimen amalgam filling (0.68 mSv / y) which is less than the allowable limit for exposure of the general people set the World Health Organization (WHO), a (1 mSv / y). (Author)

  20. Effect of fill volume on solidification characteristics of DI (deionized) water in a spherical capsule – An experimental study

    International Nuclear Information System (INIS)

    Chandrasekaran, P.; Cheralathan, M.; Velraj, R.

    2015-01-01

    The present study aims to investigate the solidification characteristics of water, as the PCM (phase change material), due to the effect of fill volume of PCM in a spherical capsule. The experiments were conducted with the spherical capsule, filling it with water of 80, 85, 90, 92 and 95 percentage of its full volume and immersing it in a constant temperature bath maintained at various temperatures. It was observed that the increase in fill volume had a significant influence in reducing the degree of supercooling and it was eliminated with 95% fill volume. Further, the increase in fill volume had a considerable effect in advancing the commencement of solidification. Increasing the temperature potential enhanced the heat flux during the solidification of first 50% of PCM mass and its effect was more pronounced at higher fill volumes. The heat flux was increased several fold particularly at 95% fill volume making it highly suitable for applications that demand large cooling load in a short duration. Hence the proper selection of fill volume and temperature driving potential is essential to achieve overall energy efficiency while designing the CTES (cool thermal energy storage) system. - Highlights: • Supercooling was eliminated with 95% fill volume at all surrounding bath temperature. • The effect of higher fill volume is more pronounced with higher temperature potential. • 50% mass is solidified in 10% of solidification duration with 95% fill volume at −12 °C. • Several fold increase in heat flux is achieved with 95% fill volume at −12 °C. • Combination of fill volume and temperature potential is essential for good design.

  1. Mechanical evaluation of bone gap filled with rigid formulations castor oil polyurethane and chitosan in horses

    Directory of Open Access Journals (Sweden)

    Rodrigo Crispim Moreira

    Full Text Available ABSTRACT: Often fractures of long bones in horses are comminuted and form bone gaps, which represent a major challenge for the fixation of these fractures by loss of contact between the fragments. Bone grafts help in treating this kind of fracture and synthetic materials have been gaining ground because of the limitations of autologous and heterologous grafts. In this study were performed compressive non destructive test in 10 bones with complete cross-bone gap in mid-diaphyseal of the third metacarpal bone of horses. Using a mechanism of "crossing" the 10 bones were used in the three groups (control, castor oil poliuretane and chitosan according to the filling material. After the test with maximum load of 1000N bone had a gap filled by another material and the test was repeated. Deformations caused on the whole bone, plate and bone tissue near and distant of gap were evaluated, using strain gauges adhered to the surface at these locations. There was a reduction in bone deformation from 14% (control to 3,5% and 4,8% by filling the gap with Chitosan and castor oil respectively, and a reduction of strain on the plate of 96% and 85% by filling gap with chitosan and castor respectively. An increase in intensity and direction of deformations occurred in bone near to gap after its filling; however, there was no difference in bone deformations occurring far the gap.

  2. Influence of high energy β-radiation on thermoelectric performance of filled skutterudites compounds

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jikun, E-mail: jikunchen@seas.harvard.edu [CAS Key Laboratory of Materials for Energy Conversion, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Zha, Hao [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education, Beijing (China); Xia, Xugui; Qiu, Pengfei; Li, Yulong [CAS Key Laboratory of Materials for Energy Conversion, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Wang, Chuanjing; Han, Yunsheng [Nuctech Company Limited, Beijing (China); Shi, Xun; Chen, Lidong [CAS Key Laboratory of Materials for Energy Conversion, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Jin, Qingxiu [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education, Beijing (China); Chen, Huaibi, E-mail: chenhb@mail.tsinghua.edu.cn [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education, Beijing (China)

    2015-08-15

    Highlights: • Impact by MeV β-rays irradiation on skutterudite TE material was investigated. • Monte-Carlo simulation is used to simulate the deposited energy irradiations. • The high deposited energy does not change the TE performance. • The light irradiation does not show a significant impact on TE materials. - Abstract: The influence of MeV β-rays irradiation on the thermoelectric performance of n-type filled skutterudite material has been investigated using an electron accelerator. Using a Monte-Carlo simulation base on Fluka code, the deposited energy in the sample material from the irradiation is estimated, which shows a large power deposited around 50 W/mm. Nevertheless, the thermoelectric performances of the filled skutterudite samples are compared before and after irradiations. It indicates that the thermoelectric material will not be easily jeopardized by ‘light’ irradiations with energy lower than MeV range.

  3. Influence of high energy β-radiation on thermoelectric performance of filled skutterudites compounds

    International Nuclear Information System (INIS)

    Chen, Jikun; Zha, Hao; Xia, Xugui; Qiu, Pengfei; Li, Yulong; Wang, Chuanjing; Han, Yunsheng; Shi, Xun; Chen, Lidong; Jin, Qingxiu; Chen, Huaibi

    2015-01-01

    Highlights: • Impact by MeV β-rays irradiation on skutterudite TE material was investigated. • Monte-Carlo simulation is used to simulate the deposited energy irradiations. • The high deposited energy does not change the TE performance. • The light irradiation does not show a significant impact on TE materials. - Abstract: The influence of MeV β-rays irradiation on the thermoelectric performance of n-type filled skutterudite material has been investigated using an electron accelerator. Using a Monte-Carlo simulation base on Fluka code, the deposited energy in the sample material from the irradiation is estimated, which shows a large power deposited around 50 W/mm. Nevertheless, the thermoelectric performances of the filled skutterudite samples are compared before and after irradiations. It indicates that the thermoelectric material will not be easily jeopardized by ‘light’ irradiations with energy lower than MeV range

  4. Electrically conductive composite material

    Science.gov (United States)

    Clough, Roger L.; Sylwester, Alan P.

    1989-01-01

    An electrically conductive composite material is disclosed which comprises a conductive open-celled, low density, microcellular carbon foam filled with a non-conductive polymer or resin. The composite material is prepared in a two-step process consisting of first preparing the microcellular carbon foam from a carbonizable polymer or copolymer using a phase separation process, then filling the carbon foam with the desired non-conductive polymer or resin. The electrically conductive composites of the present invention has a uniform and consistant pattern of filler distribution, and as a result is superior over prior art materials when used in battery components, electrodes, and the like.

  5. Cytotoxic evaluation of hydroxyapatite-filled and silica/hydroxyapatite-filled acrylate-based restorative composite resins: An in vitro study.

    Science.gov (United States)

    Chadda, Harshita; Naveen, Sangeetha Vasudevaraj; Mohan, Saktiswaren; Satapathy, Bhabani K; Ray, Alok R; Kamarul, Tunku

    2016-07-01

    Although the physical and mechanical properties of hydroxyapatite-filled dental restorative composite resins have been examined, the biocompatibility of these materials has not been studied in detail. The purpose of this in vitro study was to analyze the toxicity of acrylate-based restorative composite resins filled with hydroxyapatite and a silica/hydroxyapatite combination. Five different restorative materials based on bisphenol A-glycidyl methacrylate (bis-GMA) and tri-ethylene glycol dimethacrylate (TEGDMA) were developed: unfilled (H0), hydroxyapatite-filled (H30, H50), and silica/hydroxyapatite-filled (SH30, SH50) composite resins. These were tested for in vitro cytotoxicity by using human bone marrow mesenchymal stromal cells. Surface morphology, elemental composition, and functional groups were determined by scanning electron microscopy (SEM), energy-dispersive x-ray spectroscopy (EDX), and Fourier-transformed infrared spectroscopy (FTIR). The spectra normalization, baseline corrections, and peak integration were carried out by OPUS v4.0 software. Both in vitro cytotoxicity results and SEM analysis indicated that the composite resins developed were nontoxic and supported cell adherence. Elemental analysis with EDX revealed the presence of carbon, oxygen, calcium, silicon, and gold, while the presence of methacrylate, hydroxyl, and methylene functional groups was confirmed through FTIR analysis. The characterization and compatibility studies showed that these hydroxyapatite-filled and silica/hydroxyapatite-filled bis-GMA/TEGDMA-based restorative composite resins are nontoxic to human bone marrow mesenchymal stromal cells and show a favorable biologic response, making them potential biomaterials. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Controlled low strength materials (CLSM), reported by ACI Committee 229

    International Nuclear Information System (INIS)

    Rajendran, N.

    1997-01-01

    Controlled low-strength material (CLSM) is a self-compacted, cementitious material used primarily as a backfill in lieu of compacted fill. Many terms are currently used to describe this material including flowable fill, unshrinkable fill, controlled density fill, flowable mortar, flowable fly ash, fly ash slurry, plastic soil-cement, soil-cement slurry, K-Krete and other various names. This report contains information on applications, material properties, mix proportioning, construction and quality-control procedures. This report's intent is to provide basic information on CLSM technology, with emphasis on CLSM material characteristics and advantages over conventional compacted fill. Applications include backfills, structural fills, insulating and isolation fills, pavement bases, conduit bedding, erosion control, void filling, and radioactive waste management

  7. Buoyancy of gas-filled bladders at great depth

    Science.gov (United States)

    Priede, Imants G.

    2018-02-01

    At high hydrostatic pressures exceeding 20 MPa or 200 bar, equivalent to depths exceeding ca.2000 m, the behaviour of gases deviates significantly from the predictions of standard equations such as Boyle's Law, the Ideal Gas Law and Van der Waals equation. The predictions of these equations are compared with experimental data for nitrogen, oxygen and air at 0 °C and 15 °C, at pressures up to 1100 bar (110 MPa) equivalent to full ocean depth of ca. 11000 m. Owing to reduced compressibility of gases at high pressures, gas-filled bladders at full ocean depth have a density of 847 kg m-3 for Oxygen, 622 kg m-3 for Nitrogen and 660 kg m-3 for air providing potentially useful buoyancy comparable with that available from man-made materials. This helps explain why some of the deepest-living fishes at ca. 7000 m depth (700 bar or 70 MPa) have gas-filled swim bladders. A table is provided of the density and buoyancy of oxygen, nitrogen and air at 0 °C and 15 °C from 100 to 1100 bar.

  8. Fissure fillings from Gideaa, central Sweden

    International Nuclear Information System (INIS)

    Tullborg, E.L.; Larsson, S.Aa.

    1983-08-01

    The most frequent fissure filling minerals at Gideaa are calcite, chlorite, pyrite, laumontite, stilbite, smectite, quartz and epidote. Potentially young minerals, i.e. minerals which can be formed during present conditions, are smectite, calcite and quartz, Equilibrium calculations show that these minerals can be stable in the water analysed from Gideaa. In borehole Gi 2, the water exhibits a greater equilibrium with existing minerals in the fissures than water from Gi 4. This is due to the recharge of the water in Gi 4 and discharge of the water in Gi 2. When carbonate saturated water penetrated through the bedrock, calcite precipitated within the more superficial portions of the rock. However, both calcite and zeolite fissures fillings are associated with certain zones in the drill holes. A large number of fractures can be concluded to be of post-Jotnian age. Stilbite, calcite and smectite are associated with these fractures. Laumontite can also be assumed to belong here. The dolerites in the area exhibit a high fracture frequency but a relatively low hydraulic conductivity. This is due to the fact that smectite is very prevalent in the dolerite fractures, Several generations of fracturefilling minerals (above all calcite) have been found in a single fracture. Stable isotope analyses of fissure filling calcites indicate that there are three different groups of calcite. Most of the calcites could not have been precipitated from water of present-day isotope composition at Gideaa, whereas recent calcite may be found in one of the groups. Another group of calcite was precipitated during hydro-thermal conditions.(author)

  9. The effect of tube filling on the electronic properties of Fe filled carbon nanotubes

    International Nuclear Information System (INIS)

    Linganiso, Ella C.; Chimowa, George; Franklyn, Paul J.; Bhattacharyya, Somnath; Coville, Neil J.

    2012-01-01

    Graphical abstract: HRTEM image of a twisted CNT filled with a bent single crystal of Fe. Insets from top to bottom show the power spectra of the corresponding regions, indicating the twisting of the Fe lattice. Inset in the top right shows the relative angling of the lattice fringes to accommodate the twisting of the Fe. Highlights: ► Synthesis of Fe filled CNTs with Fe content varying from 3 to 35%. ► TEM analysis indicates that Fe in the tubes is in contact with the CNTs. ► TEM analysis reveals that α-Fe crystallizes after CNT formation. ► Temperature dependent electronic transport measurements performed. ► Conductivity varies with the % Fe filling in the CNTs. - Abstract: Carbon nanotubes filled with Fe nanostructures (Fe-CNTs) were synthesized using an injection method in a 1-stage horizontal CVD furnace and a bubbling method in a 2-stage horizontal CVD reactor. Fe-CNTs were obtained through the pyrolysis of a mixture of dichlorobenzene and ferrocene in 5%H 2 /Ar. Metal impurities from the Fe-CNTs were removed using 1 M HCl solution. CNTs filled with crystalline Fe nanoparticles, nanorods and nanowires were obtained using these procedures. An intimate interaction between the Fe and the CNT was established by HRTEM studies. The α-Fe phase was observed to be the most dominant fraction found in the synthesized Fe-CNTs. The Fe 2 O 3 residue obtained from the TGA analysis revealed the amount of Fe filled inside the CNTs and this ranged between 3 and 31% by mass after purification. The temperature dependence of the conductivity in the temperature range between 2.5 and 100 K for an entangled network of Fe-CNTs was measured. An increase in conductivity due to the increased Fe filling inside the CNTs with increased temperature was observed. The observed temperature dependence was explained in terms of variable range hopping (VRH) conduction mechanisms. A transition from Efros–Shklovskii behavior at low % Fe filling of the CNTs to Mott 3D VRH behavior at

  10. Multiple scattering theory for space filling potentials

    International Nuclear Information System (INIS)

    Butler, W.H.; Brown, R.G.; Nesbet, R.K.

    1990-01-01

    Multiple scattering theory (MST) provides an efficient technique for solving the wave equation for the special case of muffin-tin potentials. Here MST is extended to treat space filling non-muffin tin potentials and its validity, accuracy and efficiency are tested by application of the two dimensional empty lattice test. For this test it is found that the traditional formulation of MST does not coverage as the number of partial waves is increased. A simple modification of MST, however, allows this problem to be solved exactly and efficiently. 15 refs., 3 tabs

  11. Le déficit de filles

    International Development Research Centre (IDRC) Digital Library (Canada)

    de la population est une tendance plus récente. C. Le déficit de filles. Le déséquilibre du ratio hommes-femmes en Inde. D. R. O. I. T. S. D. E. S. F. E. M. M. E. S. E. T. P. A. R. T. IC. I. P. A. T. IO. N. C. I. T. O. Y. E. N. N. E. CENTRE DE. RECHERCHES. POUR LE. DÉVELOPPEMENT. INTERNATIONAL. CRDI : Jason Taylor ...

  12. Evaluation of Flowable Fill Surface Performance

    Science.gov (United States)

    2016-11-01

    general, traditional flowable fill is a low- viscosity , grout-like, cementitious blend commonly composed of portland cement, fine aggregate, and water...93.7 45.0 19.6 % Finer No. 200 7.0 0.5 9.1 % Gravel 2.2 0.0 56.1 % Sand 90.8 99.5 34.8 % Silt 3.2 < 0.5 6.8 % Clay 3.8 < 0.5 2.3 Fineness Modulus

  13. Dielectric properties of nanosilica filled epoxy nanocomposites

    Indian Academy of Sciences (India)

    M G Veena

    Polymer nanocomposites are the 21st century engineering materials with wide range of ... the electronic industry for dielectric materials in electrical insulation ..... be ascribed to the interface barriers and chain entangle- ments towards the ...

  14. Fracture-filling minerals as uranium sinks and sources, a natural analogue study at Palmottu, Finland

    International Nuclear Information System (INIS)

    Cui, D.; Eriksen, T.

    2000-01-01

    The nucleation of a mineral crystal and its growth in groundwater carrying fractures 300 m above the Palmottu uranium deposit provide an impressive example of geochemical selectivity of uranium. Fracture-filling material was collected from a 3 mm thick fracture at depth 74.8-75 m (drillcore R348). SEM and EDS analyses on a thin section of the original fracture-filling show that the fracture filling is heterogeneous, composing mineral crystal particles and very porous clay-rich aggregates. The results of INAA on millimetre-sized single mineral crystals and aggregates selected from grinded fracture-filling show that porous aggregates (composed of clays and micrometer sized mineral particles) contain up to 1000 ppm U, which is higher than the average of the whole fracture-filling (400 ppm) and host rock related millimetre sized mineral particles (18-100 ppm). 233 U/ 238 U isotope exchange proves that a large fraction of the uranium in the fracture-filling is not easily exchanged with uranium in the solution. The amount of 238 U released in the isotope exchange experiment is too high to be explained by reversible U(VI) sorption. Oxidation state analyses show that 30% of the uranium exists as U(IV). Laboratory batch experiment at anoxic conditions proved that pyrite can immobilise U(VI). (orig.)

  15. Simulations of indirectly driven gas-filled capsules at the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Weber, S. V.; Casey, D. T.; Eder, D. C.; Pino, J. E.; Smalyuk, V. A.; Remington, B. A.; Rowley, D. P.; Yeamans, C. B.; Tipton, R. E.; Barrios, M.; Benedetti, R.; Berzak Hopkins, L.; Bleuel, D. L.; Bond, E. J.; Bradley, D. K.; Caggiano, J. A.; Callahan, D. A.; Cerjan, C. J.; Clark, D. S.; Divol, L. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); and others

    2014-11-15

    Gas-filled capsules imploded with indirect drive on the National Ignition Facility have been employed as symmetry surrogates for cryogenic-layered ignition capsules and to explore interfacial mix. Plastic capsules containing deuterated layers and filled with tritium gas provide a direct measure of mix of ablator into the gas fuel. Other plastic capsules have employed DT or D{sup 3}He gas fill. We present the results of two-dimensional simulations of gas-filled capsule implosions with known degradation sources represented as in modeling of inertial confinement fusion ignition designs; these are time-dependent drive asymmetry, the capsule support tent, roughness at material interfaces, and prescribed gas-ablator interface mix. Unlike the case of cryogenic-layered implosions, many observables of gas-filled implosions are in reasonable agreement with predictions of these simulations. Yields of TT and DT neutrons as well as other x-ray and nuclear diagnostics are matched for CD-layered implosions. Yields of DT-filled capsules are over-predicted by factors of 1.4–2, while D{sup 3}He capsule yields are matched, as well as other metrics for both capsule types.

  16. Liquid-filled ionization chamber temperature dependence

    Energy Technology Data Exchange (ETDEWEB)

    Franco, L. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain)]. E-mail: luciaff@usc.es; Gomez, F. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Iglesias, A. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pardo, J. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pazos, A. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pena, J. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Zapata, M. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain)

    2006-05-10

    Temperature and pressure corrections of the read-out signal of ionization chambers have a crucial importance in order to perform high-precision absolute dose measurements. In the present work the temperature and pressure dependences of a sealed liquid isooctane filled ionization chamber (previously developed by the authors) for radiotherapy applications have been studied. We have analyzed the thermal response of the liquid ionization chamber in a {approx}20 deg. C interval around room temperature. The temperature dependence of the signal can be considered linear, with a slope that depends on the chamber collection electric field. For example, a relative signal slope of 0.27x10{sup -2}K{sup -1} for an operation electric field of 1.67x10{sup 6}Vm{sup -1} has been measured in our detector. On the other hand, ambient pressure dependence has been found negligible, as expected for liquid-filled chambers. The thermal dependence of the liquid ionization chamber signal can be parametrized within the Onsager theory on initial recombination. Considering that changes with temperature of the detector response are due to variations in the free ion yield, a parametrization of this dependence has been obtained. There is a good agreement between the experimental data and the theoretical model from the Onsager framework.

  17. GRAVITY PIPELINE TRANSPORT FOR HARDENING FILLING MIXTURES

    Directory of Open Access Journals (Sweden)

    Leonid KROUPNIK

    2015-12-01

    Full Text Available In underground mining of solid minerals becoming increasingly common development system with stowing hardening mixtures. In this case the natural ore array after it is replaced by an artificial excavation of solidified filling mixture consisting of binder, aggregates and water. Such a mixture is prepared on the surface on special stowing complexes and transported underground at special stowing pipelines. However, it is transported to the horizons of a few kilometers, which requires a sustainable mode of motion of such a mixture in the pipeline. Hardening stowing mixture changes its rheological characteristics over time, which complicates the calculation of the parameters of pipeline transportation. The article suggests a method of determining the initial parameters of such mixtures: the status coefficient, indicator of transportability, coefficient of hydrodynamic resistance to motion of the mixture. These indicators characterize the mixture in terms of the possibility to transport it through pipes. On the basis of these indicators is proposed methodology for calculating the parameters of pipeline transport hardening filling mixtures in drift mode when traffic on the horizontal part of the mixture under pressure column of the mixture in the vertical part of the backfill of the pipeline. This technique allows stable operation is guaranteed to provide pipeline transportation.

  18. Filling behaviour of wood plastic composites

    Science.gov (United States)

    Duretek, I.; Lucyshyn, T.; Holzer, C.

    2017-01-01

    Wood plastic composites (WPC) are a young generation of composites with rapidly growing usage within the plastics industry. The advantages are the availability and low price of the wood particles, the possibility of partially substituting the polymer in the mixture and sustainable use of the earth’s resources. The current WPC products on the market are to a large extent limited to extruded products. Nowadays there is a great interest in the market for consumer products in more use of WPC as an alternative to pure thermoplastics in injection moulding processes. This work presents the results of numerical simulation and experimental visualisation of the mould filling process in injection moulding of WPC. The 3D injection moulding simulations were done with the commercial software package Autodesk® Moldflow® Insight 2016 (AMI). The mould filling experiments were conducted with a box-shaped test part. In contrast to unfilled polymers the WPC has reduced melt elasticity so that the fountain flow often does not develop. This results in irregular flow front shapes in the moulded part, especially at high filler content.

  19. Transparent Metal-Salt-Filled Polymeric Radiation Shields

    Science.gov (United States)

    Edwards, David; Lennhoff, John; Harris, George

    2003-01-01

    "COR-RA" (colorless atomic oxygen resistant -- radiation shield) is the name of a transparent polymeric material filled with x-ray-absorbing salts of lead, bismuth, cesium, and thorium. COR-RA is suitable for use in shielding personnel against bremsstrahlung radiation from electron-beam welding and industrial and medical x-ray equipment. In comparison with lead-foil and leaded-glass shields that give equivalent protection against x-rays (see table), COR-RA shields are mechanically more durable. COR-RA absorbs not only x-rays but also neutrons and rays without adverse effects on optical or mechanical performance. The formulation of COR-RA with the most favorable mechanical-durability and optical properties contains 22 weight percent of bismuth to absorb x-rays, plus 45 atomic percent hydrogen for shielding against neutrons.

  20. Decayed/missing/filled teeth and shortened dental arches in Tanzanian adults.

    NARCIS (Netherlands)

    Sarita, P.T.N.; Witter, D.J.; Kreulen, C.M.; Matee, M.I.N.; Hof, M.A. van 't; Creugers, N.H.J.

    2004-01-01

    PURPOSE: This study assessed decayed/missing/filled teeth (DMFT), presence of occlusal units, and prevalence of shortened dental arches in a Tanzanian adult population. MATERIALS AND METHODS: The dental state of samples of the Tanzanian population was studied. Oral examinations were conducted on

  1. Light propagation in optical crystal powders: effects of particle size and volume filling factor

    International Nuclear Information System (INIS)

    GarcIa-Ramiro, B; Illarramendi, M A; Aramburu, I; Fernandez, J; Balda, R; Al-Saleh, M

    2007-01-01

    In this work, we analyse the light propagation in some laser and nonlinear crystal powders. In particular, we study the dependence of the diffusive absorption lengths and the transport lengths on particle size and volume filling factor. The theoretical calculations have been made by assuming a diffusive propagation of light in these materials

  2. Partial discharge patterns and surface deterioration in voids in filled and unfilled epoxy

    DEFF Research Database (Denmark)

    Holbøll, Joachim; Henriksen, Mogens

    1992-01-01

    /height analyses were performed over a period of 2400 h and showed very characteristic discharge patterns for each material combination. A unique behavior with regard to changes of pulse repetition rate and maximum apparent charge was observed for PD in alumina- and silica-filled epoxy. The void surfaces were...

  3. Effect of Opalescence(®) bleaching gels on the elution of bulk-fill composite components.

    Science.gov (United States)

    Schuster, Lena; Reichl, Franz-Xaver; Rothmund, Lena; He, Xiuli; Yang, Yang; Van Landuyt, Kirsten L; Kehe, Kai; Polydorou, Olga; Hickel, Reinhard; Högg, Christof

    2016-02-01

    Bleaching treatments can affect release of components from conventional composites. In this continuing study the influence of two different bleaching gels on the elution of bulk-fill composite components was investigated. The composites Tetric EvoCeram(®) Bulk Fill, QuiXFil™ and X-tra fil were treated with the bleaching gels Opalescence PF 15% (PF 15%) for 5 h and PF 35% (PF 35%) for 30 min and then stored in methanol and water for 24 h and 7 d. The eluates were analyzed by gas chromatography/mass spectrometry (GC/MS). Unbleached specimens were used as control group. A total of 7 different elutable substances have been identified from the investigated composites after bleaching-treatment. Three of them were methacrylates: 2-hydroxyethyl methacrylate (HEMA), triethylene glycol dimethacrylate (TEGDMA) and trimethylolpropane trimethacrylate (TMPTMA). Compared to the unbleached controls an increase in elution after PF 15%-treatment of following compounds was found: HEMA (Tetric EvoCeram(®) Bulk Fill), TEGDMA (QuiXFil™, X-tra fil) and 4-N,N-dimethylaminobenzoic acid butyl ethoxy ester (DMABEE) (Tetric EvoCeram(®) Bulk Fill, QuiXFil™, X-tra fil). Following compounds showed a reduction in elution after PF 35%-treatment compared to controls: TEGDMA (QuiXFil™) and DMABEE (Tetric EvoCeram(®) Bulk Fill). The highest concentration of HEMA was 0.22 mmol/l (Tetric EvoCeram(®) Bulk Fill, methanol, 7 d, PF 15%), the highest concentration of TEGDMA was 0.3 mmol/l (X-tra fil, water, 7 d, PF 15%) and the highest concentration of DMABEE was 0.05 mmol/l (QuiXFil™, water, 7 d, PF 35%). PF 15% and PF 35% can lead to reduced and/or increased elution of some bulk-fill components, compared to unbleached bulk-fill composites. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  4. Autologous orbicularis muscle for filling facial folds-an experimental and clinical study.

    Science.gov (United States)

    Schellini, Silvana Artioli; Hirai, Flavio Eduardo; Hoyama, Erika; Mattos, Maila Karina; Chaves, Fernando Rodrigo; Pellizon, Claudia Helena; Padovani, Carlos Roberto

    2009-01-01

    To present a technique for filling facial folds by using autologous orbicularis oculi muscle, based on an experimental model. two studies are presented: (1) an experimental study using 15 albino guinea-pigs from which a strip of the sural triceps muscle was removed and implanted in the subcutaneous tissue of the dorsal area. The animals were sacrificed 7, 30 and 60 days after the implantation, and the material was histologically evaluated. And (2) an interventional prospective clinical trial carried out on 20 patients referred to blepharoplasty surgery. They received autologous preseptal orbicularis muscle for filling facial folds. The results where evaluated by patients satisfaction and clinical exam. the sural tricep muscle, when implanted in the subcutaneous tissue, resulted in fibrosis. The patients whom received autologous orbicularis muscle implanted for filling facial folds showed that the procedure can be successfully carried out. autologous preseptal orbicularis muscle is a good material for filling facial folds. Cicatricial tissue will be formed on its implantation site, filling the tissue gap that forms the folds on the skin.

  5. Specifying and using pulverised fuel ash as an engineered fill

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, B.G.; Coombs, R. [University of Newcastle upon Tyne, Newcastle upon Tyne (United Kingdom). Dept. of Civil Engineering

    1996-12-31

    Claims arising from incorrect use of fill materials are often due to a lack of understanding of material behaviour and incomplete or wrong specifications. This is especially the case when using waste products such as pulverised fuel ash (pfa). A review of current and proposed specifications and current practice highlights some of the problems arising when selecting design parameters and acceptance criteria for pfa. Pfa can be considered a particulate material and properties of a pfa can be ascertained at the design stage because the sources are known. Design parameters are post peak effective strength parameters taken from triaxial or direct shear tests on saturated specimens compacted to 90% of the average maximum dry density. Compaction characteristics and design parameters of a particular source can be determined from tests if it is stockpiled pfa, or historical records if it is conditioned pfa. Method compaction can be used to place pfa but site trials should be carried out to determine the best method. Experience has shown that six to eight passes are sufficient, but usually the movement of construction traffic during tipping and spreading pfa will give the minimum required density. Inundation has little effect on compacted ash provided the water content is within acceptable limits, that is within 20% of the average optimum water content. 6 refs., 6 figs., 3 tabs.

  6. 33 CFR 183.564 - Fuel tank fill system.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Fuel tank fill system. 183.564...) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Manufacturer Requirements § 183.564 Fuel tank fill system. (a) Each fuel fill opening must be located so that a gasoline overflow of up to five...

  7. 46 CFR 98.25-65 - Filling density.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Filling density. 98.25-65 Section 98.25-65 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS SPECIAL... § 98.25-65 Filling density. (a) The filling density, or the percent ratio of the liquefied gas that may...

  8. 46 CFR 98.25-50 - Filling and discharge pipes.

    Science.gov (United States)

    2010-10-01

    ... with a secondary remote control of a type acceptable to the Commandant. (c) The excess flow, internal... 46 Shipping 4 2010-10-01 2010-10-01 false Filling and discharge pipes. 98.25-50 Section 98.25-50... § 98.25-50 Filling and discharge pipes. (a) Filling connections shall be provided with one of the...

  9. Filling the gap between buffer and rock in the deposition hole

    International Nuclear Information System (INIS)

    Marjavaara, P.; Kivikoski, H.

    2011-06-01

    The purpose of this study was to investigate different methods and materials which could be used for filling the gap between bentonite buffer and rock in the deposition hole. This work included a short literature survey of the previous gap filling tests which have been done in the recent years. The experimental work done during the study was divided in two phases. In the first phase small scale laboratory experiments were done using several different bentonite materials, material combinations and installation methods for 25 mm and 35 mm gaps. The sizes of these rectangular gap elements used in these tests were approximately 1 m in height and 2 m wide. Based on the first stage results the second sets of experiments were commenced. This time two materials and two methods were used in larger scale with gap widths of 35 mm and 50 mm. The large scale tests were done with cylinder shaped elements which had real size deposition hole radius of 1.75 m but the height was limited to 2 meters. Materials used in these gap filling tests included bentonite pellets and granules and their combination mixtures. Installation methods studied were free fall pouring method, shotcrete spraying method, Proctor hammer compaction method and two vibration methods to verify their functioning with these materials, material types and material forms. The achieved dry density was determined after each filling. The homogeneities of the fillings were also studied with X-ray imaging. The results from the small scale tests suggest that all the filling materials and methods used during the test would have high enough dry density average value needed by current buffer design options. The dry density values ranged from 800-1200 kg/m 3 . The lowest values were noted from free fall pouring of the largest Cebogel QSE pellets and the highest values were obtained from compacted small grain size Minelco bentonite. The X-ray images and their analysis showed that Minelco and Ibeco Seal S-FGS had the most

  10. Polymerization Behavior and Mechanical Properties of High-Viscosity Bulk Fill and Low Shrinkage Resin Composites.

    Science.gov (United States)

    Shibasaki, S; Takamizawa, T; Nojiri, K; Imai, A; Tsujimoto, A; Endo, H; Suzuki, S; Suda, S; Barkmeier, W W; Latta, M A; Miyazaki, M

    The present study determined the mechanical properties and volumetric polymerization shrinkage of different categories of resin composite. Three high viscosity bulk fill resin composites were tested: Tetric EvoCeram Bulk Fill (TB, Ivoclar Vivadent), Filtek Bulk Fill posterior restorative (FB, 3M ESPE), and Sonic Fill (SF, Kerr Corp). Two low-shrinkage resin composites, Kalore (KL, GC Corp) and Filtek LS Posterior (LS, 3M ESPE), were used. Three conventional resin composites, Herculite Ultra (HU, Kerr Corp), Estelite ∑ Quick (EQ, Tokuyama Dental), and Filtek Supreme Ultra (SU, 3M ESPE), were used as comparison materials. Following ISO Specification 4049, six specimens for each resin composite were used to determine flexural strength, elastic modulus, and resilience. Volumetric polymerization shrinkage was determined using a water-filled dilatometer. Data were evaluated using analysis of variance followed by Tukey's honestly significant difference test (α=0.05). The flexural strength of the resin composites ranged from 115.4 to 148.1 MPa, the elastic modulus ranged from 5.6 to 13.4 GPa, and the resilience ranged from 0.70 to 1.0 MJ/m 3 . There were significant differences in flexural properties between the materials but no clear outliers. Volumetric changes as a function of time over a duration of 180 seconds depended on the type of resin composite. However, for all the resin composites, apart from LS, volumetric shrinkage began soon after the start of light irradiation, and a rapid decrease in volume during light irradiation followed by a slower decrease was observed. The low shrinkage resin composites KL and LS showed significantly lower volumetric shrinkage than the other tested materials at the measuring point of 180 seconds. In contrast, the three bulk fill resin composites showed higher volumetric change than the other resin composites. The findings from this study provide clinicians with valuable information regarding the mechanical properties and

  11. Filling bore-holes with explosive

    Energy Technology Data Exchange (ETDEWEB)

    Alfredsson, S H

    1965-03-02

    In this device for filling boreholes formed in a rock formation with particulate explosive, the explosive is conveyed into the hole by means of a pressure fluid through a tube which has a lesser diameter than the hole. The tube is characterized by a lattice work arranged externally on it, and having a structure adapted to allow passage of a pressure fluid returning between the tube and the wall of the hole, but retaining particles of explosive entrained by the returning pressure fluid. In another arrangement of the device, the lattice work has the form of a brush, including filaments or bristles which are dimensioned to bridge the spacing between the tube and the wall of the hole. (12 claims)

  12. Alleviate Cellular Congestion Through Opportunistic Trough Filling

    Directory of Open Access Journals (Sweden)

    Yichuan Wang

    2014-04-01

    Full Text Available The demand for cellular data service has been skyrocketing since the debut of data-intensive smart phones and touchpads. However, not all data are created equal. Many popular applications on mobile devices, such as email synchronization and social network updates, are delay tolerant. In addition, cellular load varies significantly in both large and small time scales. To alleviate network congestion and improve network performance, we present a set of opportunistic trough filling schemes that leverage the time-variation of network congestion and delay-tolerance of certain traffic in this paper. We consider average delay, deadline, and clearance time as the performance metrics. Simulation results show promising performance improvement over the standard schemes. The work shed lights on addressing the pressing issue of cellular overload.

  13. Internal Accident Report: fill it out!

    CERN Multimedia

    2012-01-01

    It is important to report all accidents, near-misses and dangerous situations so that they can be avoided in the future.   Reporting these events allows the relevant services to take appropriate action and implement corrective and preventive measures. It should be noted that the routing of the internal accident report was recently changed to make sure that the people who need to know are informed. Without information, corrective action is not possible. Without corrective action, there is a risk that the events will recur. As soon as you experience or see something amiss, fill out an internal accident report! If you have any questions the HSE Unit will be happy to answer them. Contact us at safety-general@cern.ch. The HSE Unit

  14. Neutron transmission measurements on hydrogen filled microspheres

    International Nuclear Information System (INIS)

    Dyrnjaja, Eva; Hummel, Stefan; Keding, Marcus; Smolle, Marie-Theres; Gerger, Joachim; Zawisky, Michael

    2014-01-01

    Hollow microspheres are promising candidates for future hydrogen storage technologies. Although the physical process for hydrogen diffusion through glass is well understood, measurements of static quantities (e.q. hydrogen pressure inside the spheres) as well as dynamic properties (e.g. diffusion rate of hydrogen through glass) are still difficult to handle due to the small size of the spheres (d≈15μm). For diffusion rate measurements, the long-term stability of the experiment is also mandatory due to the relatively slow diffusion rate. In this work, we present an accurate and long-term stable measurement technique for static and dynamic properties, using neutron radiography. Furthermore, possible applications for hydrogen filled microspheres within the scope of radiation issues are discussed

  15. LHC Abort Gap Filling by Proton Beam

    CERN Document Server

    Fartoukh, Stéphane David; Shaposhnikova, Elena

    2004-01-01

    Safe operation of the LHC beam dump relies on the possibility of firing the abort kicker at any moment during beam operation. One of the necessary conditions for this is that the number of particles in the abort gap should be below some critical level defined by quench limits. Various scenarios can lead to particles filling the abort gap. Time scales associated with these scenarios are estimated for injection energy and also coast where synchrotron radiation losses are not negligible for uncaptured particle motion. Two cases are considered, with RF on and RF off. The equilibrium distribution of lost particles in the abort gap defines the requirements for maximum tolerable relative loss rate and as a consequence the minimum acceptable longitudinal lifetime of the proton beam in collision.

  16. Evaluation of the performance degradation at PAFC effect of electrolyte fill-level on electrode performance

    Energy Technology Data Exchange (ETDEWEB)

    Kitai, Takashi; Uchida, Hiroyuki; Watanabe, Masahiro [Yamanashi Univ., Kofu (Japan)] [and others

    1996-12-31

    As a complimentary research project to the demonstration project of 5MW and 1MW PAFC plants, the mechanism and rate of deterioration of the cells and stacks have been studied from 1995 FY, with the objective of establishing an estimation method for the service life-time of the cell stacks. This work has been performed in the Basic Research Project, as part of that project on PAFC`s, selecting four subjects (Electrocatalysts degradation, Electrolyte fill-level, Cell material corrosion, Electrolyte loss) as the essential factors relating to the life-time. In this report, we will exhibit the effect of the electrolyte fill-level on the electrode performances.

  17. Dynamic Moisture Sorption and Desorption in Fumed Silica-filled Silicone Foam

    Energy Technology Data Exchange (ETDEWEB)

    Trautschold, Olivia Carol [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-02

    Characterizing dynamic moisture sorption and desorption in fumed silica-filled silicone foam is necessary for determining material compatibilities and life predictions, particularly in sealed environments that may be exposed to a range of environmental conditions. Thermogravimetric analysis (TGA) and near infrared spectroscopy (NIR) were performed on S5470 fumed silica-filled silicone foam to determine the weight percent of moisture at saturation. Additionally, TGA was used to determine the time, temperature, and relative humidity levels required for sorption and desorption of physisorbed moisture in S5470.

  18. Quantum oscillations and ferromagnetic hysteresis observed in iron filled multiwall carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Barzola-Quiquia, Jose; Klingner, Niko; Molle, Axel [Division of Superconductivity and Magnetism, University of Leipzig, D-04103 Leipzig (Germany); Leonhardt, Albrecht [Leibniz Institute for Solid State and Materials Research (IFW) Dresden, Helmholtzstrasse 20, 01069 Dresden (Germany)

    2011-07-01

    Carbon-based materials as multiwall carbon nanotubes (MWCNT) are attractive for spintronics because spin is only weakly coupled to the lattice, leading to large spin-flip scattering length and long spin relaxation times. In this contribution we have investigated the electrical transport properties of iron filled MWCNT (outer diameter 150 nm, inner diameter 25 nm and length 2000 nm) as a function of temperature and magnetic field. We observed quantum interference effects, i.e. universal conductance fluctuations, and weak localization effects. The in-plane magnetoresistance shows typical butterfly structure revealing the ferromagnetic properties of the Fe-filled MWCNT. The ferromagnetic hysteresis was observed up to 40K.

  19. The order and volume fill rates in inventory control systems

    DEFF Research Database (Denmark)

    Thorstenson, Anders; Larsen, Christian

    2011-01-01

    This paper differentiates between an order (line) fill rate and a volume fill rate and specifies their performance for different inventory control systems. When the focus is on filling complete customer orders rather than total quantities the order fill rate would be the preferred service level...... measure. The main result shows how the order and volume fill rates are related in magnitude. Earlier results derived for a single-item, single-stage, continuous review inventory system with backordering and constant lead times controlled by a base-stock policy are extended in different directions...

  20. Oxygen Compatibility of Brass-Filled PTFE Compared to Commonly Used Fluorinated Polymers for Oxygen Systems

    Science.gov (United States)

    Herald, Stephen D.; Frisby, Paul M.; Davis, Samuel Eddie

    2009-01-01

    Safe and reliable seal materials for high-pressure oxygen systems sometimes appear to be extinct species when sought out by oxygen systems designers. Materials that seal well are easy to find, but these materials are typically incompatible with oxygen, especially in cryogenic liquid form. This incompatibility can result in seals that leak, or much worse, seals that easily ignite and burn during use. Materials that are compatible with oxygen are easy to find, such as the long list of compatible metals, but these metallic materials are limiting as seal materials. A material that seals well and is oxygen compatible has been the big game in the designer's safari. Scientists at the Materials Combustion Research Facility (MCRF), part of NASA/Marshall Space Flight Center (MSFC), are constantly searching for better materials and processes to improve the safety of oxygen systems. One focus of this effort is improving the characteristics of polymers used in the presence of an oxygen enriched environment. Very few systems can be built which contain no polymeric materials; therefore, materials which have good impact resistance, low heat of combustion, high auto-ignition temperature and that maintain good mechanical properties are essential. The scientists and engineers at the Materials Combustion Research Facility, in cooperation with seal suppliers, are currently testing a new formulation of polytetrafluoroethylene (PTFE) with Brass filler. This Brass-filled PTFE is showing great promise as a seal and seat material for high pressure oxygen systems. Early research has demonstrated very encouraging results, which could rank this material as one of the best fluorinated polymers ever tested. This paper will compare the data obtained for Brass-filled PTFE with other fluorinated polymers, such as TFE-Teflon (PTFE) , Kel-F 81, Viton A, Viton A-500, Fluorel , and Algoflon . A similar metal filled fluorinated polymer, Salox-M , was tested in comparison to Brass-filled PTFE to

  1. 3D printing cybersecurity: detecting and preventing attacks that seek to weaken a printed object by changing fill level

    Science.gov (United States)

    Straub, Jeremy

    2017-06-01

    Prior work by Zeltmann, et al. has demonstrated the impact of small defects and other irregularities on the structural integrity of 3D printed objects. It posited that such defects could be introduced intentionally. The current work looks at the impact of changing the fill level on object structural integrity. It considers whether the existence of an appropriate level of fill can be determined through visible light imagery-based assessment of a 3D printed object. A technique for assessing the quality and sufficiency of quantity of 3D printed fill material is presented. It is assessed experimentally and results are presented and analyzed.

  2. Transport properties of partially-filled Ce{sub y}Co{sub 4}Sb{sub 12}

    Energy Technology Data Exchange (ETDEWEB)

    Uher, C; Chen, B; Hu, S; Morelli, D T; Meisner, G P

    1997-07-01

    The authors have investigated the magnetic and transport properties of Ce{sub y}Co{sub 4}Sb{sub 12} filled skutterudites with the filling fraction y {le} 0.1. These compounds are n-type materials that develop a magnetic moment upon the presence of trivalent cerium. Cerium has a strong influence on all transport properties and even in small amounts it drastically reduces the lattice thermal conductivity. The resulting figures of merit are comparable to the values established previously for the p-type filled skutterudites.

  3. Processing method of radiation concrete waste and manufacturing method for radioactive waste solidifying filling mortar

    International Nuclear Information System (INIS)

    Sukekiyo, Mitsuaki; Okamoto, Masamichi

    1998-01-01

    Radioactive concrete wastes are crushed and pulverized. Fine solid granular materials caused by the pulverization are classified and the grain size is controlled so that the maximum grain size is 2.5mm, with the grains having a grain size of up to 0.15mm being up to 30% by weight to form fine aggregates. Separated and recovered fine concrete powders are classified and the size of the powder is controlled within a range of from 3,000 to 15,000cm 2 /g which is smaller than cement particles to form fine powders having a stable quality suitable as a mixing agent. The fine aggregates and the mixing agent are mixed to form a filling mortar (filler) for solidifying radioactive wastes. The filling mortar is filled together with other radioactive wastes in a drum to form a waste body in a drum. With such a constitution, crushed radioactive concrete wastes can be reutilized completely. (I.N.)

  4. Electromechanical stability of electro-active silicone filled with high permittivity particles undergoing large deformation

    International Nuclear Information System (INIS)

    Liu, Liwu; Liu, Yanju; Zhang, Zhen; Leng, Jinsong; Li, Bo

    2010-01-01

    In this paper, an expression for the permittivity of electro-active silicone undergoing large deformation with high permittivity particles filled uniformly has been proposed. Two expressions are proposed for the permittivity, one based on experimental tests and the other based on the theory of composite material. By applying the thermodynamic model incorporating linear dielectric permittivity and nonlinear hyperelastic performance, the mechanical performance and electromechanical stability of the coupling system constituted by silicone filled with PMN–PT have been studied. The results show that the critical electric field decreases, namely the stability performance of the system declines when the content of PMN–PT c(v) increases and the electrostrictive coefficients increase. The results are beneficial for us to understand deeply the influence of the filled particle on the stability performance of silicone and to guide the design and manufacture of actuators and sensors based on dielectric elastomers

  5. Periapical repair after root canal filling with different root canal sealers.

    Science.gov (United States)

    Tanomaru-Filho, Mário; Tanomaru, Juliane Maria Guerreiro; Leonardo, Mario Roberto; da Silva, Lea Assed Bezerra

    2009-01-01

    The aim of this study was to evaluate periapical repair after root canal filling with different endodontic sealers. Sixty-four root canals from dog s teeth were filled, divided into 4 groups (n=16). Root canals were instrumented with K-type files and irrigated with 1% sodium hypochlorite solution. Root canals were filled in the same session by active lateral condensation of the cones and sealers: Intrafill, AH Plus, Roeko Seal and Resilon/Epiphany System. After 90 days, the animals were euthanized and the tissues to be evaluated were processed and stained with hematoxylin and eosin. For histopathological analysis, the following parameters were evaluated: inflammatory process, mineralized tissue resorption, and apical mineralized tissue deposition. Histopathological analysis demonstrated that Intrafill had less favorable results in terms of apical and periapical repair, compared to the other sealers (p0.05). In conclusion, AH Plus and the materials Roeko Seal and Epiphany are good options for clinical use in Endodontics.

  6. Utilization of crushed radioactive concrete for mortar to fill waste container void space

    International Nuclear Information System (INIS)

    Ishikura, Takeshi; Ohnishi, Kazuhiko; Oguri, Daiichiro; Ueki, Hiroyuki

    2004-01-01

    Minimizing the volume of radioactive waste generated during dismantling of nuclear power plants is a matter of great importance. In Japan waste forms buried in a shallow burial disposal facility as low level radioactive waste must be solidified by cement or other materials with adequate strength and must provide no harmful opening. The authors have developed an improved method to minimize radioactive waste volume by utilizing radioactive concrete for fine aggregate for mortars to fill void space in waste containers. Tests were performed with pre-placed concrete waste and with filling mortar using recycled fine aggregate produced from concrete. It was estimated that the improved method substantially increases the waste fill ratio in waste containers, thereby decreasing the total volume of disposal waste. (author)

  7. Synthesis and characteristics of Fe-filled multi-walled carbon nanotubes for biomedical application

    Energy Technology Data Exchange (ETDEWEB)

    Moench, I [Leibniz Institute of Solid State and Materials Research Dresden, IFW-Dresden, Helmholtzstr. 20, D-01069 Dresden (Germany); Leonhardt, A [Leibniz Institute of Solid State and Materials Research Dresden, IFW-Dresden, Helmholtzstr. 20, D-01069 Dresden (Germany); Meye, A [Department of Urology, Technical University Dresden, Fetscherstrasse 74, D-01062 Dresden (Germany); Hampel, S [Leibniz Institute of Solid State and Materials Research Dresden, IFW-Dresden, Helmholtzstr. 20, D-01069 Dresden (Germany); Kozhuharova-Koseva, R [Leibniz Institute of Solid State and Materials Research Dresden, IFW-Dresden, Helmholtzstr. 20, D-01069 Dresden (Germany); Elefant, D [Leibniz Institute of Solid State and Materials Research Dresden, IFW-Dresden, Helmholtzstr. 20, D-01069 Dresden (Germany); Wirth, M P [Department of Urology, Technical University Dresden, Fetscherstrasse 74, D-01062 Dresden (Germany); Buechner, B [Leibniz Institute of Solid State and Materials Research Dresden, IFW-Dresden, Helmholtzstr. 20, D-01069 Dresden (Germany)

    2007-04-15

    Multifunctional nanocontainers can be produced based on partially filled Fe-multi walled carbon nanotubes (MWCNTs). Using thermal decomposition ferrocene filled nanotubes can be grown aligned on substrates. The encapsulated metal nanowires have diameters of 5-30 nm and a length up to few microns. They consist of single-crystalline of {alpha} and {gamma}-Fe- phases. Using heat treatment, it is possible to transform {gamma}-Fe into {alpha}-Fe. With the aid of wet chemical methods the nanotubes can be opened and additionally filled with an agent, e.g., therapeutic agents (carboplatin) or other metals (copper). Initial studies do not show a high toxicity over a period of 440 days. These materials can be used for drug delivery and hyperthermia. The specific absorption rate (SAR) is greater than 100W/(g-{alpha}-Fe) in a magnetic field of 18kA/m (f = 250kHz)

  8. Calculations on the effect of pellet filling on the rewetting of overheated nuclear reactor fuel pins

    International Nuclear Information System (INIS)

    Pearson, K.G.; Loveless, J.

    1977-03-01

    Numerical solutions of the rewetting equations are presented which show the effect of filler material and gas gap on the rate of rewetting of an overheated fuel pin. It is shown that taking the presence of the fuel into account can lead to a large reduction in the calculated rewetting speed compared with a calculation which neglects the presence of fuel. The effect is most marked in conditions where rewetting speeds tend to be already low, such as at high pin temperatures and low ambient pressure. A comparison is made between the predictions of the present method and experimental data obtained on zircaloy and stainless steel pins filled with magnesia and with boron nitride. In all cases filling the pins produced a large reduction in rewetting speed and the agreement between the calculated and measured effect was encouraging. It is concluded that the presence of the UO 2 pellet filling should be taken into account when calculating rewetting speeds in safety assessments. (author)

  9. Urethane foam void filling. Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-12-01

    Under the decontamination and decommissioning (D and D) Implementation Plan of the United States Department of Energy's (DOE's) Fernald Environmental Management Project (FEMP), non-recyclable process components and debris that are removed from buildings undergoing D and D are disposed of in an on-site disposal facility (OSDF). Critical to the design and operation of the FEMP's OSDF are provisions to protect against subsidence of the OSDF's cap. Subsidence of the cap could occur if void spaces within the OSDF were to collapse under the overburden of debris and the OSDF cap. Subsidence may create depressions in the OSDF's cap in which rainwater could collect and eventually seep into the OSDF. To minimize voids in the FEMP's OSDF, large metallic components are cut into smaller segments that can be arranged more compactly when placed in the OSDF. Component segmentation using an oxy-acetylene torch was the baseline approach used by the FEMP's D and D contractor on Plant 1, B and W Services, Inc., for the dismantlement and size-reduction of large metal components. Although this technology has performed satisfactorily, it is time-consuming, labor-intensive and costly. Use of the oxy-acetylene torch exposes workers to health and safety hazards including the risk of burns, carbon monoxide, and airborne contamination of residual lead-based paints and other contaminants on the surface of the components being segmented. In addition, solvents used to remove paint from the components before segmenting them emit flammable, noxious fumes. This demonstration investigated the feasibility of placing large vessels intact in the OSDF without segmenting them. To prevent the walls of the vessels from collapsing under the overburden or from degradation, an innovative approach was employed which involved filling the voids in the vessels with a fluid material that hardened on standing. The hardened filling would support the walls of the vessels, and prevent them from collapsing. This report

  10. Antimicrobial activity of different filling pastes for deciduous tooth treatment

    Directory of Open Access Journals (Sweden)

    Bruna Feltrin ANTONIAZZI

    2015-01-01

    Full Text Available Guedes-Pinto paste is the filling material most employed in Brazil for endodontic treatment of deciduous teeth; however, the Rifocort® ointment has been removed. Thus, the aim of this study was to investigate the antimicrobial potential of filling pastes, by proposing three new pharmacological associations to replace Rifocort® ointment with drugs of already established antimicrobial power: Nebacetin® ointment, 2% Chlorhexidine Gluconate gel, and Maxitrol® ointment. A paste composed of Iodoform, Rifocort® ointment and Camphorated Paramonochlorophenol (CPC was employed as the gold standard (G1. The other associations were: Iodoform, Nebacetin® ointment and CPC (G2; Iodoform, 2% Chlorhexidine Digluconate gel and CPC (G3; Iodoform, Maxitrol® ointment and CPC (G4. The associations were tested for Staphylococcus aureus (S. aureus, Streptococcus mutans (S. mutans, Streptococcus oralis (S. oralis, Enterococcus faecalis (E. faecalis, Escherichia coli (E. coli, and Bacillus subtilis (B. subtilis, using the methods of dilution on solid medium – orifice agar – and broth dilution. The results were tested using statistical analysis ANOVA and Kruskal-Wallis. They showed that all the pastes had a bacteriostatic effect on all the microorganisms, without any statistically significant difference, compared with G1. S. aureus was statistically significant (multiple comparison test of Tukey, insofar as G2 and G3 presented the worst and the best performance, respectively. All associations were bactericidal for E. coli, S. aureus, S. mutans and S. oralis. Only G3 and G4 were bactericidal for E. faecalis, whereas no product was bactericidal for B. subtilis. Thus, the tested pastes have antimicrobial potential and have proved acceptable for endodontic treatment of primary teeth.

  11. Dose Reduction Study in Vaginal Balloon Packing Filled With Contrast for HDR Brachytherapy Treatment

    International Nuclear Information System (INIS)

    Saini, Amarjit S.; Zhang, Geoffrey G.; Finkelstein, Steven E.; Biagioli, Matthew C.

    2011-01-01

    Purpose: Vaginal balloon packing is a means to displace organs at risk during high dose rate brachytherapy of the uterine cervix. We tested the hypothesis that contrast-filled vaginal balloon packing reduces radiation dose to organs at risk, such as the bladder and rectum, in comparison to water- or air-filled balloons. Methods and Materials: In a phantom study, semispherical vaginal packing balloons were filled with air, saline solution, and contrast agents. A high dose rate iridium-192 source was placed on the anterior surface of the balloon, and the diode detector was placed on the posterior surface. Dose ratios were taken with each material in the balloon. Monte Carlo (MC) simulations, by use of the MC computer program DOSXYZnrc, were performed to study dose reduction vs. balloon size and contrast material, including commercially available iodine- and gadolinium-based contrast agents. Results: Measured dose ratios on the phantom with the balloon radius of 3.4 cm were 0.922 ± 0.002 for contrast/saline solution and 0.808 ± 0.001 for contrast/air. The corresponding ratios by MC simulations were 0.895 ± 0.010 and 0.781 ± 0.010. The iodine concentration in the contrast was 23.3% by weight. The dose reduction of contrast-filled balloon ranges from 6% to 15% compared with water-filled balloon and 11% to 26% compared with air-filled balloon, with a balloon size range between 1.4 and 3.8 cm, and iodine concentration in contrast of 24.9%. The dose reduction was proportional to the contrast agent concentration. The gadolinium-based contrast agents showed less dose reduction because of much lower concentrations in their solutions. Conclusions: The dose to the posterior wall of the bladder and the anterior wall of the rectum can be reduced if the vaginal balloon is filled with contrast agent in comparison to vaginal balloons filled with saline solution or air.

  12. Multi objective optimization of foam-filled circular tubes for quasi-static and dynamic responses

    Directory of Open Access Journals (Sweden)

    Fauzan Djamaluddin

    Full Text Available AbstractFuel consumption and safety are currently key aspects in automobile design. The foam-filled thin-walled aluminium tube represents a potentially effective material for use in the automotive industry, due to its energy absorption capability and light weight. Multi-objective crashworthiness design optimization for foam-filled double cylindrical tubes is presented in this paper. The double structures are impacted by a rigid wall simulating quasi-static and dynamic loadings. The optimal parameters under consideration are the minimum peak crushing force and maximum specific energy absorption, using the non-dominated sorting genetic algorithm-II (NSGA-II technique. Radial basis functions (RBF and D-Optimal are adopted to determine the more complex crashworthiness functional objectives. The comparison is performed by finite element analysis of the impact crashworthiness characteristics in tubes under static and dynamic loads. Finally, the optimum crashworthiness performance of empty and foam-filled double tubes is investigated and compared to the traditional single foam-filled tube. The results indicate that the foam-filled double aluminium circular tube can be recommended for crashworthy structures.

  13. Dynamic analysis of bulk-fill composites: Effect of food-simulating liquids.

    Science.gov (United States)

    Eweis, Ahmed Hesham; Yap, Adrian U-Jin; Yahya, Noor Azlin

    2017-10-01

    This study investigated the effect of food simulating liquids on visco-elastic properties of bulk-fill restoratives using dynamic mechanical analysis. One conventional composite (Filtek Z350 [FZ]), two bulk-fill composites (Filtek Bulk-fill [FB] and Tetric N Ceram [TN]) and a bulk-fill giomer (Beautifil-Bulk Restorative [BB]) were evaluated. Specimens (12 × 2 × 2mm) were fabricated using customized stainless steel molds. The specimens were light-cured, removed from their molds, finished, measured and randomly divided into six groups. The groups (n = 10) were conditioned in the following mediums for 7 days at 37°C: air (control), artificial saliva (SAGF), distilled water, 0.02N citric acid, heptane, 50% ethanol-water solution. Specimens were assessed using dynamic mechanical testing in flexural three-point bending mode and their respective mediums at 37°C and a frequency range of 0.1-10Hz. The distance between the supports were fixed at 10mm and an axial load of 5N was employed. Data for elastic modulus, viscous modulus and loss tangent were subjected to ANOVA/Tukey's tests at significance level p food-simulating liquids on the visco-elastic properties of bulk-fill composites was material and medium dependent. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Filled aperture concepts for the Terrestrial Planet Finder

    Science.gov (United States)

    Ridgway, Stephen T.

    2003-02-01

    Filled aperture telescopes can deliver a real, high Strehl image which is well suited for discrimination of faint planets in the vicinity of bright stars and against an extended exo-zodiacal light. A filled aperture offers a rich variety of PSF control and diffraction suppression techniques. Filled apertures are under consideration for a wide spectral range, including visible and thermal-IR, each of which offers a significant selection of biomarker molecular bands. A filled aperture visible TPF may be simpler in several respects than a thermal-IR nuller. The required aperture size (or baseline) is much smaller, and no cryogenic systems are required. A filled aperture TPF would look and act like a normal telescope - vendors and users alike would be comfortable with its design and operation. Filled aperture telescopes pose significant challenges in production of large primary mirrors, and in very stringent wavefront requirements. Stability of the wavefront control, and hence of the PSF, is a major issue for filled aperture systems. Several groups have concluded that these and other issues can be resolved, and that filled aperture options are competitive for a TPF precursor and/or for the full TPF mission. Ball, Boeing-SVS and TRW have recently returned architecture reviews on filled aperture TPF concepts. In this paper, I will review some of the major considerations underlying these filled aperture concepts, and suggest key issues in a TPF Buyers Guide.

  15. Surface Patterning Using Diazonium Ink Filled Nanopipette.

    Science.gov (United States)

    Zhou, Min; Yu, Yun; Blanchard, Pierre-Yves; Mirkin, Michael V

    2015-11-03

    Molecular grafting of diazonium is a widely employed surface modification technique. Local electrografting of this species is a promising approach to surface doping and related properties tailoring. The instability of diazonium cation complicates this process, so that this species was generated in situ in many reported studies. In this Article, we report the egress transfer of aryl diazonium cation across the liquid/liquid interface supported at the nanopipette tip that can be used for controlled delivery this species to the external aqueous phase for local substrate patterning. An aryl diazonium salt was prepared with weakly coordinating and lipophilic tetrakis(pentafluorophenyl)borate anion stable as a solid and soluble in low polarity media. The chemically stable solution of this salt in 1,2-dichloroethane can be used as "diazonium ink". The ink-filled nanopipette was employed as a tip in the scanning electrochemical microscope (SECM) for surface patterning with the spatial resolution controlled by the pipette orifice radius and a few nanometers film thickness. The submicrometer-size grafted spots produced on the HOPG surface were located and imaged with the atomic force microscope (AFM).

  16. [Creep of amalgam fillings under clasp rests].

    Science.gov (United States)

    Borchers, L; Jung, T; West, M

    1989-10-01

    A clinically realistic experiment was set up to obtain information on the amount of vertical settling of clasp rests in amalgam restorations under functional loading. Mesioocclusal cavities were prepared in 16 lower molar specimens cast in brass. The cavities were filled with amalgam and provided with a mesial rest seat. A constant load of 100 N was applied via a simplified (experimental) saddle to a cobalt-chromium E-clasp cast to the saddle. The duration of the load corresponded to 160 days of clinical function. The chronological course of vertical displacement was analyzed mathematically. According to this result the process can be divided into three components: settling immediately upon load initiation (mean value 96 microns, transition creep (mean value 25 microns) and creep ata constant rate (mean value 15 microns). The mean overall vertical displacement of the rests was 136 microns, the maximum value 287 microns. These findings suggest that vertical settling of a clasp rest into its seat in an amalgam restoration may eventually result in significant changes in occlusion and may almost completely exhaust gingival resilience.

  17. Polymer deformation and filling modes during microembossing

    Science.gov (United States)

    Rowland, Harry D.; King, William P.

    2004-12-01

    This work investigates the initial stages of polymer deformation during hot embossing micro-manufacturing at processing temperatures near the glass transition temperature (Tg) of polymer films having sufficient thickness such that polymer flow is not supply limited. Several stages of polymer flow can be observed by employing stamp geometries of various widths and varying imprint conditions of time and temperature to modulate polymer viscosity. Experiments investigate conditions affecting cavity filling phenomena, including apparent polymer viscosity. Stamps with periodic ridges of height and width 4 µm and periodicity 30, 50 and 100 µm emboss trenches into polymethyl methacrylate films at Tg - 10 °C time, temperature and load are correlated with replicated polymer shape, height and imprinted area. Polymer replicates are measured by atomic force microscopy and inspected by scanning electron microscopy. Cavity size and the temperature dependence of polymer viscosity significantly influence the nature of polymer deformation in hot embossing micro-manufacturing and must be accounted for in rational process design.

  18. Turbulent flow in a partially filled pipe

    Science.gov (United States)

    Ng, Henry; Cregan, Hope; Dodds, Jonathan; Poole, Robert; Dennis, David

    2017-11-01

    Turbulent flow in a pressure driven pipe running partially full has been investigated using high-speed 2D-3C Stereoscopic Particle Imaging Velocimetry. With the field-of-view spanning the entire pipe cross section we are able to reconstruct the full three dimensional quasi-instantaneous flow field by invoking Taylor's hypothesis. The measurements were carried out over a range of flow depths at a constant Reynolds number based on hydraulic diameter and bulk velocity of Re = 32 , 000 . In agreement with previous studies, the ``velocity dip'' phenomenon, whereby the location of the maximum streamwise velocity occurs below the free surface was observed. A mean flow secondary current is observed near the free surface with each of the counter-rotating rollers filling the half-width of the pipe. Unlike fully turbulent flow in a rectangular open channel or pressurized square duct flow where the secondary flow cells appear in pairs about a corner bisector, the mean secondary motion observed here manifests only as a single pair of vortices mirrored about the pipe vertical centreline.

  19. A Histologic Evaluation on Tissue Reaction to Three Implanted Materials (MTA, Root MTA and Portland Cement Type I in the Mandible of Cats

    Directory of Open Access Journals (Sweden)

    F. Sasani

    2004-09-01

    Full Text Available Statement of Problem: Nowadays Mineral Trioxide aggregate (MTA is widely used for root end fillings, pulp capping, perforation repair and other endodontic treatments.Investigations have shown similar physical and chemical properties for Portland cement and Root MTA with those described for MTA.Purpose: The aim of this in vitro study was to evaluate the tissue reaction to implanted MTA, Portland cement and Root MTA in the mandible of cats.Materials and Methods: Under asepsis condition and general anesthesia, a mucoperiosteal flap, following the application of local anesthesia, was elevated to expose mandibular symphysis. Two small holes in both sides of mandible were drilled. MTA, Portland cement and Root MTA were mixed according to the manufacturers, recommendation and placed in bony cavities. In positive control group, the test material was Zinc oxide powder plus tricresoformalin. In negative control group, the bony cavities were left untreated. After 3,6 and 12 weeks, the animals were sacrificed and the mandibular sections were prepared for histologic examination under light microscope. The presence and thickness of inflammation, presence of fibrosis capsule, the severity of fibrosis and bone formation were investigated. The data were submitted to Exact Fisher test, chi square test and Kruskal-Wallis test for statistical analysis.Results: No statistically significant differences were found in the degree of inflammation,presence of fibrotic capsule, severity of fibrosis and inflammation thickness between Root MTA, Portland cement and MTA (P>0.05. There was no statistical difference in boneformation between MTA and Portland cement (P>0.05. However, bone formation was not found in any of the Root MTA specimens and the observed tissue was exclusively of fibrosis type.Conclusion: The physical and histological results observed with MTA are similar to those of Root MTA and Portland cement. Additionally, all of these three materials are biocompatible

  20. Effect of Amount of 3-Methacryloxy Propyl Thrimethoxysilane Coupling Agent and Nano Filling Structure on Physic-Mechanical Properties of Dental Resin Composite

    Directory of Open Access Journals (Sweden)

    Farbod Tondnevis

    2017-07-01

    Full Text Available Many researchers in the field of dental polymeric base nano composite investigated the effect filling morphology and filling material content on mechanical and physical properties of construction after setting reaction. Our present study concentrated on the effect of ϒ metacryloxy propyloxt tri metoxy silane (ϒ MPS content as coupling agent (orgnic material on physical and mechanical performance of nano composite material. It was shown that despite of contraction after setting reaction, all this properties improved and efficient silanization can efficiently affect structural integrity of dental filling nano composite

  1. Effects of selective attention on perceptual filling-in.

    Science.gov (United States)

    De Weerd, P; Smith, E; Greenberg, P

    2006-03-01

    After few seconds, a figure steadily presented in peripheral vision becomes perceptually filled-in by its background, as if it "disappeared". We report that directing attention to the color, shape, or location of a figure increased the probability of perceiving filling-in compared to unattended figures, without modifying the time required for filling-in. This effect could be augmented by boosting attention. Furthermore, the frequency distribution of filling-in response times for attended figures could be predicted by multiplying the frequencies of response times for unattended figures with a constant. We propose that, after failure of figure-ground segregation, the neural interpolation processes that produce perceptual filling-in are enhanced in attended figure regions. As filling-in processes are involved in surface perception, the present study demonstrates that even very early visual processes are subject to modulation by cognitive factors.

  2. The order and volume fill rates in inventory control systems

    DEFF Research Database (Denmark)

    Thorstenson, Anders; Larsen, Christian

    2014-01-01

    This paper differentiates between an order (line) fill rate and a volume fill rate and specifies their performance for different inventory control systems. When the focus is on filling complete customer orders rather than total demanded quantity the order fill rate would be the preferred service...... level measure. The main result shows how the order and volume fill rates are related in magnitude. Earlier results derived for a single-item, single-stage, continuous review inventory system with backordering and constant lead times controlled by a base-stock policy are extended in different directions...... extensions consider more general inventory control review policies with backordering, as well as some relations between service measures. A particularly important result in the paper concerns an alternative service measure, the customer order fill rate, and shows how this measure always exceeds the other two...

  3. Tank 18-F And 19-F Tank Fill Grout Scale Up Test Summary

    International Nuclear Information System (INIS)

    Stefanko, D.; Langton, C.

    2012-01-01

    High-level waste (HLW) tanks 18-F and 19-F have been isolated from FTF facilities. To complete operational closure the tanks will be filled with grout for the purpose of: (1) physically stabilizing the tanks, (2) limiting/eliminating vertical pathways to residual waste, (3) entombing waste removal equipment, (4) discouraging future intrusion, and (5) providing an alkaline, chemical reducing environment within the closure boundary to control speciation and solubility of select radionuclides. This report documents the results of a four cubic yard bulk fill scale up test on the grout formulation recommended for filling Tanks 18-F and 19-F. Details of the scale up test are provided in a Test Plan. The work was authorized under a Technical Task Request (TTR), HLE-TTR-2011-008, and was performed according to Task Technical and Quality Assurance Plan (TTQAP), SRNL-RP-2011-00587. The bulk fill scale up test described in this report was intended to demonstrate proportioning, mixing, and transportation, of material produced in a full scale ready mix concrete batch plant. In addition, the material produced for the scale up test was characterized with respect to fresh properties, thermal properties, and compressive strength as a function of curing time.

  4. TANK 18-F AND 19-F TANK FILL GROUT SCALE UP TEST SUMMARY

    Energy Technology Data Exchange (ETDEWEB)

    Stefanko, D.; Langton, C.

    2012-01-03

    High-level waste (HLW) tanks 18-F and 19-F have been isolated from FTF facilities. To complete operational closure the tanks will be filled with grout for the purpose of: (1) physically stabilizing the tanks, (2) limiting/eliminating vertical pathways to residual waste, (3) entombing waste removal equipment, (4) discouraging future intrusion, and (5) providing an alkaline, chemical reducing environment within the closure boundary to control speciation and solubility of select radionuclides. This report documents the results of a four cubic yard bulk fill scale up test on the grout formulation recommended for filling Tanks 18-F and 19-F. Details of the scale up test are provided in a Test Plan. The work was authorized under a Technical Task Request (TTR), HLE-TTR-2011-008, and was performed according to Task Technical and Quality Assurance Plan (TTQAP), SRNL-RP-2011-00587. The bulk fill scale up test described in this report was intended to demonstrate proportioning, mixing, and transportation, of material produced in a full scale ready mix concrete batch plant. In addition, the material produced for the scale up test was characterized with respect to fresh properties, thermal properties, and compressive strength as a function of curing time.

  5. Improved thermoelectric performance of n-type Ca and Ca-Ce filled skutterudites

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Daniel R.; Liu, Chang; Ellison, Nicole D. [Optimal CAE, Plymouth, Michigan 48170 (United States); Salvador, James R.; Meyer, Martin S.; Haddad, Daad B. [General Motors Research and Development, Warren, Michigan 48090 (United States); Wang, Hsin; Cai, W. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States)

    2014-12-28

    Thermoelectric (TE) technology for use in automotive waste heat recovery is being advanced by General Motors with support from the US Department of Energy. Skutterudites are a very promising material for this application of TE technology due to their superior mechanical properties and good TE performance. Double-filled Yb{sub x}Ba{sub y}Co{sub 4}Sb{sub 12} with ZT values around 1.1 at 750 K are the best performing n-type skutterudites produced on a large scale using an economically viable approach of melt spinning (MS) in conjunction with spark plasma sintering (SPS). Another economical production method on the tons scale, the melt quench annealing (MQA) technique, has been recently claimed by Treibacher Industrie AG, further information is available [G. Rogl et al., Acta Mater. 76, 434–448 (2014)]. A possible hurdle to commercial implementation of these materials is the use of rare earths as the fillers to reduce thermal conductivity and improve the electrical transport properties. It will be shown herein that skutterudites double-filled with Ca and Ce, both of which are lower-cost fillers, display markedly different TE properties depending on whether they are produced by MQA or MS + SPS synthesis techniques. Ca and Ce double-filled skutterudites prepared by MS + SPS have TE properties that are superior to the same compositions prepared by MQA and that are comparable to the best performing Yb and Ba filled materials. Furthermore, the results of this study suggest that the unusually poor transport properties of MQA Ca-filled skutterudites can be ascribed to deleterious secondary phases, which is contrary to reports in the literature attempting to explain these irregularities via band structure features.

  6. Color stability of bulk-fill and incremental-fill resin-based composites polished with aluminum-oxide impregnated disks

    Directory of Open Access Journals (Sweden)

    Uzay Koc-Vural

    2017-05-01

    Full Text Available Objectives This study aimed to evaluate the color stability of bulk-fill and nanohybrid resin-based composites polished with 3 different, multistep, aluminum-oxide impregnated finishing and polishing disks. Materials and Methods Disk-shaped specimens (8 mm in diameter and 4 mm in thickness were light-cured between two glass slabs using one nanohybid bulk-fill (Tetric EvoCeram, Ivoclar Vivadent, one micro-hybrid bulk-fill (Quixfil, Dentsply, and two nanohybrid incremental-fill (Filtek Ultimate, 3M ESPE; Herculite XRV Ultra, Kerr resin-based composites, and aged by thermocycling (between 5 - 55℃, 3,000 cycles. Then, they were divided into subgroups according to the polishing procedure as SwissFlex (Coltène/Whaledent, Optidisc (Kerr, and Praxis TDV (TDV Dental (n = 12 per subgroup. One surface of each specimen was left unpolished. All specimens were immersed in coffee solution at 37℃. The color differences (ΔE were measured after 1 and 7 days of storage using a colorimeter based on CIE Lab system. The data were analyzed by univariate ANOVA, Mann-Whitney U test, and Friedmann tests (α = 0.05. Results Univariate ANOVA detected significant interactions between polishing procedure and composite resin and polishing procedure and storage time (p 0.05. Polishing reduced the discoloration resistance of Tetric EvoCeram/SwissFlex, Tetric EvoCeram/Praxis TDV, Quixfil-SwissFlex, and all Herculite XRV Ultra groups after 7 days storage (p < 0.05. Conclusions Discoloration resistance of bulk-fill resin-based composites can be significantly affected by the polishing procedures.

  7. Stress reduction for pillar filled structures

    Science.gov (United States)

    Nikolic, Rebecca J.; Conway, Adam; Shao, Qinghui; Voss, Lars; Cheung, Chin Li; Dar, Mushtaq A.

    2015-09-01

    According to one embodiment, an apparatus for detecting neutrons includes an array of pillars, wherein each of the pillars comprises a rounded cross sectional shape where the cross section is taken perpendicular to a longitudinal axis of the respective pillar, a cavity region between each of the pillars, and a neutron sensitive material located in each cavity region.

  8. [Cermet cements for milk tooth fillings. Preliminary results].

    Science.gov (United States)

    Hickel, R; Petschelt, A; Voss, A

    1989-06-01

    106 Ketac-Silver fillings in deciduous molars were reevaluated after 1 to 3.3 years, i.e. 25 month on the average. About 90% of 50 occlusal fillings and about 84% of 56 multisurface restorations were unchanged. Without claiming statistical evidence for their conclusiveness, we consider these results as an indication that cermet cements are a useful alternative to amalgam fillings in deciduous teeth, particularly since the life of these fillings is limited to the time until the milk tooth is physiologically lost.

  9. Method for automatic filling of nuclear fuel rod cladding tubes

    International Nuclear Information System (INIS)

    Bezold, H.

    1979-01-01

    Prior to welding the zirconium alloy cladding tubes with end caps, they are automatically filled with nuclear fuel tablets and ceramic insulating tablets. The tablets are introduced into magazine drums and led through a drying oven to a discharging station. The empty cladding tubes are removed from this discharging station and filled with tablets. A filling stamp pushes out the columns of tablets in the magazine tubes of the magazine drum into the cladding tube. Weight and measurement of length determine the filled state of the cladding tube. The cladding tubes are then led to the welding station via a conveyor belt. (DG) [de

  10. Via fill properties of organic BARCs in dual-damascene application

    Science.gov (United States)

    Huang, Runhui

    2004-05-01

    With the introduction of copper as the interconnect metal, the Dual Damascene (DD) process has been integrated into integrated circuit (IC) device fabrication. The DD process utilizes organic bottom anti-reflective coatings (BARCs) not only to eliminate the thin film interference effects but also to act as via fill materials. However, three serious processing problems are encountered with organic BARCs. One is the formation of voids, which are trapped gas bubbles (evaporating solvent, byproduct of the curing reaction and air) inside the vias. Another problem is non-uniform BARC layer thickness in different via pitch areas. The third problem is the formation of fences during plasma etch. Fences are formed from materials that are removed by plasma and subsequently deposited on the sidewall surrounding the via openings during the etching process. Voids can cause variations in BARC top thickness, optical properties, via fill percentage, and plasma etch rate. This study focuses on the factors that influence the formation of voids and addresses the ways to eliminate them by optimizing the compositions of formulations and the processing conditions. Effects of molecular weight of the polymer, nature of the crosslinker, additives, and bake temperature were examined. The molecular weight of the polymer is one of the important factors that needs to be controlled carefully. Polymers with high molecular weights tend to trap voids inside the vias. Low molecular weight polymers have low Tg and low viscosity, which enables good thermal flow so that the BARC can fill vias easily without voids. Several kinds of crosslinkers were investigated in this study. When used with the same polymer system, formulations with different crosslinkers show varying results that affect planar fill, sidewall coverage, and, in some cases, voids. Additives also can change via fill behavior dramatically, and choosing the right additive will improve the via fill property. Processing conditions such as

  11. Study of filled dolines by using 3D stereo image processing and electrical resistivity imaging

    Directory of Open Access Journals (Sweden)

    Mateja Breg Valjavec

    2014-01-01

    Full Text Available This article deals with doline degradation due to uncontrolled waste dumping in the past in the Logatec Polje in Slovenia. It introduces a concept for determining 3D geometric characteristics (shape, depth, radius, area, and volume of formerly concave landforms (i.e., recently filled dolines by using a combination of two methods: (1 photogrammetric stereo processing of archival aerial photographs and (2 electrical resistivity imaging (ERI. To represent, visualize, and study the characteristics of the former surface morphology (i.e., the dolines before they were filled, a digital terrain model (DTM for 1972 (DTM1972 was made using digital photogrammetry processing of five sequential archival aerial photographs (1972, © GURS. DTM1972 was visually and quantitatively compared with the DTM5 of the recent surface morfology (DTM5, © GURS, 2006 in order to define areas of manmade terrain differences. In general, a circular area with a higher terrain difference is an indicator of a filled doline. The calculated terrain differences also indicate the thickness of buried waste material. Three case-study dolines were selected for 3D geometric analysis and tested in the field using ERI. ERI was used to determine the genetic type of the original doline, to confirm that the buried material in the doline is actually waste, and to ascertain opportunities for further study of water pollution due to waste leakage. Based on a comparison among the ERI sections obtained using various electrode arrays, it was concluded that the basins are actually past concave landforms (i.e., dolines filled with mixed waste material having the lowest resistivity value (bellow 100 ohm-m, which differs measurably from the surrounding natural materials. The resistivity of hard stacked limestone is higher (above 1,000 ohm-m than resistivity of cracked carbonate rocks with cracks filled with loamy clay sediments while in loamy alluvial sediment resistivity falls below 150 ohm

  12. Increasing Polymer Solar Cell Fill Factor by Trap-Filling with F4-TCNQ at Parts Per Thousand Concentration.

    Science.gov (United States)

    Yan, Han; Manion, Joseph G; Yuan, Mingjian; García de Arquer, F Pelayo; McKeown, George R; Beaupré, Serge; Leclerc, Mario; Sargent, Edward H; Seferos, Dwight S

    2016-08-01

    Intrinsic traps in organic semiconductors can be eliminated by trap-filling with F4-TCNQ. Photovoltaic tests show that devices with F4-TCNQ at parts per thousand concentration outperform control devices due to an improved fill factor. Further studies confirm the trap-filling pathway and demonstrate the general nature of this finding. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Efficacy of ProTaper retreatment system in root canals filled with gutta-percha and two endodontic sealers.

    Science.gov (United States)

    Só, Marcus Vinícius Reis; Saran, Caroline; Magro, Miriam Lago; Vier-Pelisser, Fabiana Vieira; Munhoz, Marcelo

    2008-10-01

    This study evaluated the efficacy of ProTaper Universal rotary retreatment system and hand files for filling material removal during retreatment and the influence of sealer type on the presence of filling debris in the reinstrumented canals. The canals of 60 palatal roots of first molars were obturated with gutta-percha and either a zinc oxide-eugenol-based or a resin-based sealer and reinstrumented: G1, EndoFill/hand files; G2, AH Plus/hand files; G3, EndoFill/ProTaper; G4, AH Plus/ProTaper. Roots were cleaved and examined with an optical microscope, and the amount of filling debris on canal walls was analyzed on digitized images. There was no significant difference (P > .05) among the root canal thirds within each group. G3 presented significantly more filling debris than G1 in the cervical third (P = .04). In the middle third, G2/G3/G4 showed more debris than G1 (P = .03). The techniques were similar (P = .64) in the apical third. All groups presented filling debris in the 3 canal thirds after reinstrumentation.

  14. Electrical and thermal transport properties of Y bxCo4Sb12 filled skutterudites with ultrahigh carrier concentrations

    Directory of Open Access Journals (Sweden)

    Yulong Li

    2015-11-01

    Full Text Available For filled skutterudites, element Yb is one of the most common and important fillers. However, the optimal carrier concentration range in Y bxCo4Sb12 filled skutterudites has not been determined as a result of the low Yb filling fraction limit. In this study, a non-equilibrium fabrication process (MS-SPS process, consisting of a melt-spinning method and a spark plasma sintering technique, has been applied to prepare Y bxCo4Sb12 samples. The Yb filling fraction is successfully extended to 0.35, which provides the possibility to clarify the optimal carrier concentration range for Yb-filled skutterudites. High carrier concentrations, with a maximum of around 1 × 1021 cm−3, were achieved in the MS-SPS Y bxCo4Sb12 samples due to the significantly enhanced Yb filling fractions. The phase compositions, lattice parameters, electrical and thermal transport properties of the MS-SPS Y bxCo4Sb12 samples with high carrier concentrations were systematically investigated. An optimal carrier concentration range of around 5 ∼ 6 × 1020 cm−3, corresponding to the actual Yb filling fraction of around 0.21∼0.26, has been determined, which displays the highest thermoelectric performance in Y bxCo4Sb12 thermoelectric materials.

  15. COMSOL Multiphysics Model for HLW Canister Filling

    Energy Technology Data Exchange (ETDEWEB)

    Kesterson, M. R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-04-11

    The U.S. Department of Energy (DOE) is building a Tank Waste Treatment and Immobilization Plant (WTP) at the Hanford Site in Washington to remediate 55 million gallons of radioactive waste that is being temporarily stored in 177 underground tanks. Efforts are being made to increase the loading of Hanford tank wastes in glass while meeting melter lifetime expectancies and process, regulatory, and product quality requirements. Wastes containing high concentrations of Al2O3 and Na2O can contribute to nepheline (generally NaAlSiO4) crystallization, which can sharply reduce the chemical durability of high level waste (HLW) glass. Nepheline crystallization can occur during slow cooling of the glass within the stainless steel canister. The purpose of this work was to develop a model that can be used to predict temperatures of the glass in a WTP HLW canister during filling and cooling. The intent of the model is to support scoping work in the laboratory. It is not intended to provide precise predictions of temperature profiles, but rather to provide a simplified representation of glass cooling profiles within a full scale, WTP HLW canister under various glass pouring rates. These data will be used to support laboratory studies for an improved understanding of the mechanisms of nepheline crystallization. The model was created using COMSOL Multiphysics, a commercially available software. The model results were compared to available experimental data, TRR-PLT-080, and were found to yield sufficient results for the scoping nature of the study. The simulated temperatures were within 60 ºC for the centerline, 0.0762m (3 inch) from centerline, and 0.2286m (9 inch) from centerline thermocouples once the thermocouples were covered with glass. The temperature difference between the experimental and simulated values reduced to 40 ºC, 4 hours after the thermocouple was covered, and down to 20 ºC, 6 hours after the thermocouple was covered

  16. Epoxy polyurethane nanocomposites filled with fullerite

    International Nuclear Information System (INIS)

    Rozhnova, R.A.; Galatenko, N.A.; Lukashevich, S.A.; Shirokov, O.D.; Levenets', Je.G.

    2015-01-01

    New nanocomposite materials based on epoxy polyurethane (EPU) containing nanoscale fullerite in its composition are produced. The influence of small impurities of fullerite on physical and mechanical properties of the nanocomposites is established. The effect of a nanofiller and its concentration on the structure and properties of the composite and the ability to biodegradation in vitro is studied. The developed nanocomposites exhibit the biodegradability, and the presence of nanofillers in the EPU facilitates the course of the process

  17. Estimation of water-filled and air-filled porosity in the unsaturated zone, Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Nelson, P.H.

    1993-01-01

    Water content and porosity vary considerably within the unsaturated zone at Yucca Mountain. Measurement of these quantities has been based on core samples. A log-based approach offers the advantage of in-situ measurements, continuous throughout the borehole. This paper describes an algorithm which determines the air-filled and water-filled porosities from density and dielectric logs. The responses of density and dielectric logs are formulated in terms of the matrix properties, air-filled porosity and water-filled porosity. Porosity values obtained from logs from borehole USW G-2 are in reasonable agreement with estimates from core determinations

  18. EVALUATION OF DIELECTRIC CURING MONITORING INVESTIGATING LIGHT-CURING DENTAL FILLING COMPOSITES

    Directory of Open Access Journals (Sweden)

    Johannes Steinhaus

    2011-05-01

    Full Text Available The aim of this study is the evaluation of a dielectric analysis (DEA method monitoring the curing behaviour of a light curing dental filling material in real-time. The evaluation is to extract the influence of light intensity on the photo-curing process of dental composite filling materials. The intensity change is obtained by measuring the curing process at different sample depth. It could be shown that increasing sample thickness, and therefore exponentially decreasing light intensity, causes a proportional decrease in the initial curing rate. Nevertheless, the results give rise to the assumption that lower illumination intensities over a long period cause higher overall conversion, and thus better mechanical properties. This would allow for predictions of the impact of different curing-rates on the final mechanical properties.

  19. Studies on the properties of rice-husk-filled-PP composites: effect of maleated PP

    Directory of Open Access Journals (Sweden)

    Simone Maria Leal Rosa

    2009-09-01

    Full Text Available Rice husk is a by-product of rice milling process that usually finds inadequate final disposal (burning, land filling. Thermoplastics composites filled with rice husk flour are materials that offer an alternative for using this agricultural resource viewing the production of low dense materials with some specific properties. In this work composites of polypropylene (PP and rice husk flour (RHF were prepared by melt extrusion. Maleic anhydride-modified PP (MAPP was added as a coupling agent. It was verified that tensile strength decreased with filler loading. The presence of MAPP improved this property showing a strong dependence on the MAPP/RHF ratio (MAPP/RHF = 0.03 produced the best results. The density of the composites slightly increased with filler and coupling agent in comparison to pure PP. The presence of MAPP diminished more than 20% water uptake in highly-loaded composites.

  20. Gamma-Ray Bursts and Relativistic Shells: The Surface Filling Factor

    International Nuclear Information System (INIS)

    Fenimore, E.E.; Cooper, C.; Ramirez-Ruiz, E.; Sumner, M.C.; Yoshida, A.; Namiki, M.

    1999-01-01

    The variability observed in many complex gamma-ray bursts (GRBs) is inconsistent with causally connected variations in a single, symmetric, relativistic shell interacting with the ambient material (open-quotes external shocksclose quotes). Rather, either the central site must produce ∼10 50 ergs s -1 for hundreds of seconds (open-quotes internal shocksclose quotes), or the local spherical symmetry of the shell must be broken on an angular scale much smaller than Γ -1 , where Γ is the bulk Lorentz factor for the shell. The observed variability in the external shock models arises from the number of causally connected regions that (randomly) become active. We define the surface filling factor to be the ratio of the area of causally connected regions that become active to the observable area of the shell. From the observed variability in 52 BATSE bursts, we estimate the surface filling factor to be typically ∼5x10 -3 , although some values are near unity. We find that the surface filling factor, f, is ∼0.1ΔT/T in both the constant Γ phase (which probably produces the GRB) and the decelerating phase (which probably produces the X-ray afterglows). Here, ΔT is a typical timescale of variability, and T is the time since the initial signal. We analyze the 2 hr flare seen by ASCA 36 hr after the GRB and conclude that the surface filling factor must be small (10 -3 ) in the X-ray afterglow phase as well. Compared with the energy required for an isotropic shell, E iso , explanations for a low surface filling factor can either require more energy (f -1 E iso ∼10 56 ergs) or less energy [(ΔT/4T) 2 E iso ∼10 49 ergs]. Thus, the low filling factor cannot be used as a strong argument that GRBs must be internal shocks. copyright copyright 1999. The American Astronomical Society

  1. Design options for reducing the impact of the fill-tube in ICF implosion experiments on the NIF

    Science.gov (United States)

    Weber, Christopher R.; Berzak Hopkins, L. F.; Casey, D. T.; Clark, D. S.; Hammel, B. A.; Le Pape, S.; Macphee, A.; Milovich, J.; Pickworth, L. A.; Robey, H. F.; Smalyuk, V. A.; Stadermann, M.; Felker, S. J.; Nikroo, A.; Thomas, C. A.; Crippen, J.; Rice, N.

    2017-10-01

    Inertial Confinement Fusion (ICF) capsules on the National Ignition Facility (NIF) are filled with thermonuclear fuel through a fill-tube. When the capsule implodes, perturbations caused by the fill-tube allow ablator material to mix into the hot spot and reduce fusion performance. This talk will explore several design options that attempt to reduce this damaging effect. Reducing the diameter of the fill-tube and its entrance hole is the obvious course and has been tested in experiments. Simulations also show sensitivity to the amount of glue holding the fill-tube to the capsule and suggest that careful control of this feature can limit the amount of injected mass. Finally, an off-axis fill-tube reduces the initial squirt of material into the fuel and may be a way of further optimizing this engineering feature. Work performed under the auspices of the U.S. D.O.E. by Lawrence Livermore National Laboratory under Contract No. DE-AC52-07NA27344.

  2. Damage characterization for particles filled semi-crystalline polymer

    Directory of Open Access Journals (Sweden)

    Lauro Franck

    2015-01-01

    Full Text Available Damage evolution and characterization in semi-crystalline polymer filled with particles under various loadings is still a challenge. A specific damage characterization method using Digital Image Correlation is proposed for a wide range of strain rates considering tensile tests with hydraulic jacks as well as Hopkinson's bars. This damage measurement is obtained by using and adapting the SEE method [1] which was developed to characterize the behaviour laws at constant strain rates of polymeric materials in dynamic. To validate the characterization process, various damage measurement techniques are used under quasi-static conditions before to apply the procedure in dynamic. So, the well-known damage characterization by loss of stiffness technique under quasi-static loading is applied to a polypropylene. In addition, an in-situ tensile test, carried out in a microtomograph, is used to observe the cavitation phenomenon in real time. A good correlation is obtained between all these techniques and consequently the proposed technique is supposed suitable for measuring the ductile damage observed in semi-crystalline polymers under dynamic loading. By applying it to the semi-crystalline polymer at moderate and high speed loadings, the damage evolution is measured and it is observed that the damage evolution is not strain rate dependent but the failure strain on the contrary is strain rate dependent.

  3. MEMS-based Porous Silicon Preconcentrators Filled with Carbopack-B for Explosives Detection

    OpenAIRE

    Camara , El Hadji Malik; James , Franck; Breuil , Philippe; Pijolat , Christophe; Briand , Danick; De Rooij , Nicolaas F

    2014-01-01

    International audience; In this paper we report the detection of explosive compounds using a miniaturized gas preconcentrator (μGP) made of porous silicon (PS) filled in with Carbopack B as an adsorbent material. The μGP includes also a platinum heater patterned at the backside and fluidic connectors sealed on the glass cover. Our μGP is designed and optimized through fluidic and thermal simulations for meeting the requirements of trace explosives detection. The thermal mass of the device was...

  4. Computation of Thermal Development in Injection Mould Filling, based on the Distance Model

    OpenAIRE

    Andersson, Per-Åke

    2002-01-01

    The heat transfer in the filling phase of injection moulding is studied, based on Gunnar Aronsson’s distance model for flow expansion ([Aronsson], 1996). The choice of a thermoplastic materials model is motivated by general physical properties, admitting temperature and pressure dependence. Two-phase, per-phase-incompressible, power-law fluids are considered. The shear rate expression takes into account pseudo-radial flow from a point inlet. Instead of using a finite element (FEM) solver for ...

  5. Creep deformation of restorative resin-composites intended for bulk-fill placement.

    Science.gov (United States)

    El-Safty, S; Silikas, N; Watts, D C

    2012-08-01

    To determine the creep deformation of several "bulk-fill" resin-composite formulations in comparison with some other types. Six resin-composites; four bulk-fill and two conventional were investigated. Stainless steel split molds (4 mm × 6 mm) were used to prepare cylindrical specimens for creep testing. Specimens were thoroughly irradiated with 650 mW cm(-2). A total of 10 specimens for each material were divided into two groups (n = 5) according to the storage condition; Group A stored dry at 37 °C for 24h and Group B stored in distilled water at 37 °C in an incubator for 24h. Each specimen was loaded (20 MPa) for 2h and unloaded for 2h. The strain deformation was recorded continuously for 4h. Statistical analysis was performed using a two-way ANOVA followed by one-way ANOVA and the Bonferroni post hoc test at a significance level of a = 0.05. The maximum creep strain % ranged from 0.72% up to 1.55% for Group A and the range for Group B increased from 0.79% up to 1.80% due to water sorption. Also, the permanent set ranged from 0.14% up to 0.47% for Group A and from 0.20% up to 0.59% for Group B. Dependent on the material and storage condition, the percentage of creep strain recovery ranged between 64% and 81%. Increased filler loading in the bulk-fill materials decreased the creep strain magnitude. Creep deformation of all studied resin-composites increased with wet storage. The "bulk-fill" composites exhibited an acceptable creep deformation and within the range exhibited by other resin-composites. Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  6. Using Habit Reversal to Decrease Filled Pauses in Public Speaking

    Science.gov (United States)

    Mancuso, Carolyn; Miltenberger, Raymond G.

    2016-01-01

    This study evaluated the effectiveness of simplified habit reversal in reducing filled pauses that occur during public speaking. Filled pauses consist of "uh," "um," or "er"; clicking sounds; and misuse of the word "like." After baseline, participants received habit reversal training that consisted of…

  7. Theory Of Dewetting In A Filled Elastomer Under Stress

    Science.gov (United States)

    Peng, Steven T. J.

    1993-01-01

    Report presents theoretical study of dewetting between elastomeric binder and filler particles of highly filled elastomer under multiaxial tension and resulting dilatation of elastomer. Study directed toward understanding and predicting nonlinear stress-vs.-strain behavior of filled elastomeric rocket propellant, also applicable to rubber in highly loaded tire or in damping pad.

  8. Predicting heat transfer in long, R-134a filled thermosyphons

    NARCIS (Netherlands)

    Grooten, M.H.M.; Geld, van der C.W.M.

    2008-01-01

    When traditional air-to-air cooling is too voluminous, heat exchangers with long thermosyphons offer a good alternative. Experiments with a single thermosyphon with a large length-to-diameter ratio (188) and filled with R-134a are presented and analyzed. Saturation temperatures, filling ratios, and

  9. Radiodiagnosis of filled retention bronchial cysts and lung tuberculomes

    International Nuclear Information System (INIS)

    Gudz', A.E.

    1987-01-01

    Radiological semiotics of filled retention bronchial cysts in 23 patients and of lung tuberculomes in 52 is studied on the basis of the data on roentgenography, tomography and bronchography. Characteristic radiological signs of retention bronchial cysts and tuberculomes are determined. Significance of each radiological sign for differential diagnosis of filled retention bronchial cysts and lung tuberculomes is estimated

  10. Simulation of mould filling process for composite skeleton castings

    Directory of Open Access Journals (Sweden)

    M. Dziuba

    2008-04-01

    Full Text Available In this work authors showed selected results of simulation and experimental studies on temperature distribution during solidification of skeleton casting and mould filling process. The aim of conducted simulations was the choice of thermal and geometrical parameters for the needs of designed calculations of the skeleton castings and the estimation of the guidelines for the technology of manufacturing. The subject of numerical simulation was the analysis of ability of filling the channels of core by liquid metal at estability technological parameters.. Below the assumptions and results of the initial simulated calculations are presented. The total number of the nodes in the casting was 1920 and of the connectors was 5280 what gave filling of 100% for the nodes and 99,56% for the connectors in the results of the simulation. Together it resulted as 99,78 % of filling the volume of the casting. The nodes and connectors were filled up to the 30 level of the casting in the simulation. The all connectors were filled up to the 25 level of the casting in the simulation. Starting from the 25 level individual connectors at the side surface of the casting weren’t filled up. The connectors weren’t supplied by multi-level getting system. The differences of filling the levels are little (maximally 5 per cent.

  11. The automatic liquid nitrogen filling system for GDA detectors

    Indian Academy of Sciences (India)

    In addition, no physical access to the beam hall is required during routine filling operation. The system consists of ... PSI with the manual valve (MV) on the dewar kept open. For filling the detectors on one ... sequence the opening/closing of the valves depending upon the outlet temperature. By monitoring the time taken for ...

  12. Method and apparatus for filling cryogenic liquid cylinders

    International Nuclear Information System (INIS)

    Remes, S.

    1984-01-01

    A method and apparatus are disclosed for filling a portable cryogenic liquid cylinder from a large stand tank. The invention employs a regulator valve to perform an automatic throttling function whereby the pressure in the liquid cylinder is maintained at a value slightly lower than the upstream pressure in the stand tank. This significantly reduces filling losses due to flashing

  13. Gap filling strategies and error in estimating annual soil respiration

    Science.gov (United States)

    Soil respiration (Rsoil) is one of the largest CO2 fluxes in the global carbon (C) cycle. Estimation of annual Rsoil requires extrapolation of survey measurements or gap-filling of automated records to produce a complete time series. While many gap-filling methodologies have been employed, there is ...

  14. Rapid filling of pipelines with the SPH particle method

    NARCIS (Netherlands)

    Hou, Q.; Zhang, L.X.; Tijsseling, A.S.; Kruisbrink, A.C.H.

    2011-01-01

    The paper reports the development and application of a SPH (smoothed particle hydrodynamics) based simulation of rapid filling of pipelines, for which the rigid-column model is commonly used. In this paper the water-hammer equations with a moving boundary are used to model the pipe filling process,

  15. Rapid filling of pipelines with the SPH particle method

    NARCIS (Netherlands)

    Hou, Q.; Zhang, L.X.; Tijsseling, A.S.; Kruisbrink, A.C.H.

    2012-01-01

    The paper reports the development and application of a SPH (smoothed particle hydrodynamics) based simulation of rapid filling of pipelines, for which the rigid-column model is commonly used. In this paper the water-hammer equations with a moving boundary are used to model the pipe filling process,

  16. Process for automatic filling of nuclear fuel rod cans

    International Nuclear Information System (INIS)

    Bezold, H.

    1977-01-01

    A drying section is inserted in the production line for the automation of the filling process for fuel rods with nuclear fuel pellets. The pellets are taken in a drum magazine to a drying furnace and then pushed out one after the other into the can to be filled. (TK) [de

  17. Excavation/Fill/Soil Disturbance, Self-Study #31419

    Energy Technology Data Exchange (ETDEWEB)

    Grogin, Phillip W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2018-02-06

    This course, Excavation/Fill/Soil Disturbance Self-Study (#31419), presents an overview of the hazards, controls, and requirements that affect safe excavations at Los Alamos National Laboratory (LANL). An overview of the LANL excavation/fill/soil disturbance permit (EXID permit) approval process is also presented, along with potholing requirements for planning and performing excavations at LANL.

  18. Microbiological studies on bacterial isolates from penicillins filling ...

    African Journals Online (AJOL)

    Aseptic processing is a critical method for the preparation of thermolabile sterile parenteral drug products. Sterile β-lactam antibiotics are extremely deactivated by heat, so the method of choice for their processing is through aseptic filling. The consequences of contamination on aseptically-filled products are harmful to the ...

  19. 27 CFR 4.72 - Metric standards of fill.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Metric standards of fill. 4.72 Section 4.72 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS LABELING AND ADVERTISING OF WINE Standards of Fill for Wine § 4.72 Metric...

  20. Water balance of an earth fill built of organic clay

    Directory of Open Access Journals (Sweden)

    Birle Emanuel

    2016-01-01

    Full Text Available The paper presents investigations on the water balance of an earth fill built of organic clay in humid climate. As the organic soil used for the fill contains geogenetically elevated concentrations of arsenic, particular attention is paid on the seepage flow through the fill. The test fill is 5 m high, 30 m long and 25 m wide. The fill consists of the organic clay compacted at water contents wet and dry of Proctor Optimum covered by a drainage mat and a 60 cm thick top layer. For the determination of the water balance extensive measuring systems were installed. The seepage at the bottom measured so far was less than 2 % of the precipitation. The interflow in the drainage mat above the compacted organic clay was of similar magnitude. The estimated evapotranspiration reached approx. 84 % of the precipitation. According to these measurements the percolation is much lower than the percolation of many landfill covers in humid climates.

  1. Development of gap filling technique in HLW repository

    International Nuclear Information System (INIS)

    Nakashima, Hitoshi; Saito, Akira; Ishii, Takashi; Toguri, Satohito; Okihara, Mitsunobu; Iwasa, Kengo

    2016-01-01

    HLW is supposed to be disposed underground at depths more than 300 m in Japan. Buffer is an artificial barrier that controls radionuclides migrating into the groundwater. The buffer would be made of a natural swelling clay, bentonite. Construction technology for the buffer has been studied for many years, but studies for the gaps surrounding the buffer are little. The proper handling of the gaps is important for guaranteeing the functions of the buffer. In this paper, gap filling techniques using bentonite pellets have been developed in order to the gap having the same performance as the buffer. A new method for manufacturing high-density spherical pellets has been developed to fill the gap higher density ever reported. For the bentonite pellets, the filling performance and how to use were determined. And full-scale filling tests provided availability of the bentonite pellets and filling techniques. (author)

  2. Customized bentonite pellets. Manufacturing, performance and gap filling properties

    Energy Technology Data Exchange (ETDEWEB)

    Marjavaara, P.; Holt, E.; Sjoeblom, V. [VTT Technical Research Centre of Finland, Espoo (Finland)

    2013-12-15

    The goal of this work was to provide knowledge about how to manufacture customized bentonite pellets and how customized bentonite pellets perform in practice during the nuclear repository construction process. The project was mainly focused on laboratory experimental tests to optimize the pellet filling by customizing the raw materials and pellet manufacturing. Bentonite pellets were made using both extrusion and roller compaction methods. The pellets were intended for use in gaps between compacted bentonite and the rock walls in both buffer deposition holes and tunnel backfilling. Performance of different types of custom-made pellets were evaluated with regard to their ease of manufacturing, density, crush strength, abrasion resistance, water holding capacity, free swelling and also their thermal conductivity. These evaluations were done in both Finland (by VTT) and Canada (by AECL). Over 50 different varieties of pellets were roller-compaction manufactured at AECL in Canada and 20 types of extrusion pellets at VTT in Finland. The parameters that were varied during manufacturing included: bentonite raw material type, water content, pellet sizes, bentonite compaction machine parameters, use of recycled pellets, and addition of two different types of filler (illite or granitic sand) at varying addition percentages. By examining the pellets produced with these methods and materials the performance and behaviour of the bentonite pellets were evaluated in laboratory with selected tests. The work done using extrusion pellets showed that it was possible to manufacture pellets with higher water contents, up to 21 % from MX-80. This water content value was higher than what was typically possible using roller-compaction method in this study. Higher water content values allow closer compatibility with the designed bentonite buffer water content. The extrusion tests also showed that the required production simulation runs could be made successfully with reference type of MX

  3. Spectroscopic and Mechanical Properties of a New Generation of Bulk Fill Composites.

    Science.gov (United States)

    Monterubbianesi, Riccardo; Orsini, Giovanna; Tosi, Giorgio; Conti, Carla; Librando, Vito; Procaccini, Maurizio; Putignano, Angelo

    2016-01-01

    Objectives: The aims of this study were to in vitro evaluate the degree of conversion and the microhardness properties of five bulk fill resin composites; in addition, the performance of two curing lamps, used for composites polymerization, was also analyzed. Materials and Methods: The following five resin-based bulk fill composites were tested: SureFil SDR®, Fill Up!™, Filtek™, SonicFill™, and SonicFill2™. Samples of 4 mm in thickness were prepared using Teflon molds filled in one increment and light-polymerized using two LED power units. Ten samples for each composite were cured using Elipar S10 and 10 using Demi Ultra. Additional samples of SonicFill2, (3 and 5 mm-thick) were also tested. The degree of conversion (DC) was determined by Raman spectroscopy, while the Vickers microhardness (VMH) was evaluated using a microhardness tester. The experimental evaluation was carried out on top and bottom sides, immediately after curing (t0), and, on bottom, after 24 h (t24). Two-ways analysis of variance was applied to evaluate DC and VMH-values. In all analyses, the level of significance was set at p composites recorded satisfactory DCs on top and bottom sides. At t0, the top of SDR and SonicFill2 showed the highest DCs-values (85.56 ± 9.52 and 85.47 ± 1.90, respectively), when cured using Elipar S10; using Demi Ultra, SonicFill2 showed the highest DCs-values (90.53 ± 2.18). At t0, the highest DCs-values of bottom sides were recorded by SDR (84.64 ± 11.68), when cured using Elipar S10, and Filtek (81.52 ± 4.14), using Demi Ultra. On top sides, Demi Ultra lamp showed significant higher DCs compared to the Elipar S10 ( p composites showed higher VMH than the flowable or dual curing composites.

  4. Filling high aspect ratio trenches by superconformal chemical vapor deposition: Predictive modeling and experiment

    Science.gov (United States)

    Wang, Wenjiao B.; Abelson, John R.

    2014-11-01

    Complete filling of a deep recessed structure with a second material is a challenge in many areas of nanotechnology fabrication. A newly discovered superconformal coating method, applicable in chemical vapor deposition systems that utilize a precursor in combination with a co-reactant, can solve this problem. However, filling is a dynamic process in which the trench progressively narrows and the aspect ratio (AR) increases. This reduces species diffusion within the trench and may drive the component partial pressures out of the regime for superconformal coating. We therefore derive two theoretical models that can predict the possibility for filling. First, we recast the diffusion-reaction equation for the case of a sidewall with variable taper angle. This affords a definition of effective AR, which is larger than the nominal AR due to the reduced species transport. We then derive the coating profile, both for superconformal and for conformal coating. The critical (most difficult) step in the filling process occurs when the sidewalls merge at the bottom of the trench to form the V shape. Experimentally, for the Mg(DMADB)2/H2O system and a starting AR = 9, this model predicts that complete filling will not be possible, whereas experimentally we do obtain complete filling. We then hypothesize that glancing-angle, long-range transport of species may be responsible for the better than predicted filling. To account for the variable range of species transport, we construct a ballistic transport model. This incorporates the incident flux from outside the structure, cosine law re-emission from surfaces, and line-of-sight transport between internal surfaces. We cast the transport probability between all positions within the trench into a matrix that represents the redistribution of flux after one cycle of collisions. Matrix manipulation then affords a computationally efficient means to determine the steady-state flux distribution and growth rate for a given taper angle. The

  5. Cuspal Deflection of Premolars Restored with Bulk-Fill Composite Resins.

    Science.gov (United States)

    Behery, Haytham; El-Mowafy, Omar; El-Badrawy, Wafa; Saleh, Belal; Nabih, Sameh

    2016-01-01

    This in vitro study compared cuspal deflection of premolars restored with three bulk-fill composite resins to that of incrementally-restored ones with a low-shrinkage silorane-based restorative material. Forty freshly-extracted intact human upper premolars were used. Reference points at buccal and palatal cusp tips were acid-etched and composite rods were horizontally bonded to them (TPH-Spectra-HV, Dentsply). Two acrylic resin guiding paths were made for each premolar to guide beaks of a digital micrometer used for cuspal deflection measurements. Standardized MOD cavities, 3 mm wide bucco-lingually and 3.5 mm deep, were prepared on each premolar. Prepared teeth were then equally divided into four groups (n = 10) and each group was assigned to one of four composite resin (QuiXX, Dentsply; X-tra fil, Voco; Tetric EvoCeram Bulk Fill, Ivoclar Vivadent; low-shrinkage Filtek LS, 3M/ESPE). Adper Single Bond-Plus, 3M/ESPE was used with all bulk-fill restoratives. LS-System Adhesive, 3M/ESPE was used with Filtek LS. For each prepared premolar, cuspal deflection was measured in microns as the difference between two readings between reference points before and after restoration completion. Means and SDs were calculated and data statistically-analyzed using One-way ANOVA and Tukey's test. Filtek LS showed the lowest mean cuspal deflection value 6.4(0.84)μm followed by Tetric EvoCeram Bulk Fill 10.1(1.2) μm and X-tra fil 12.4(1.35)μm, while QuiXX showed the highest mean 13(1.05)μm. ANOVA indicated significant difference among mean values of groups (p composite resins tested. Filtek LS had the lowest significant mean cuspal deflection in comparison to all tested bulk-fill restoratives. The use of Tetric EvoCeram Bulk fill composite resin restorative for class II MOD cavities resulted in reduced cuspal deflection in comparison to the two other bulk-fill composite resins tested. The silorane-based Filtek LS restorative resulted in the least cuspal deflection in

  6. Quality of root fillings performed with two root filling techniques. An in vitro study using micro-CT

    DEFF Research Database (Denmark)

    Møller, L; Wenzel, A; Wegge-Larsen, AM

    2013-01-01

    -section images from Micro-computed Tomography scans. Results. All root canal fillings had voids. Permutation test showed no statistically significant difference between the two root filling techniques in relation to presence of voids (p = 0.092). A statistically significant difference in obturation time between...

  7. The water-filled versus air-filled status of vessels cut open in air: the 'Scholander assumption' revisited

    Science.gov (United States)

    M.T. Tyree; H. Cochard; P. Cruziat

    2003-01-01

    When petioles of transpiring leaves are cut in the air, according to the 'Scholander assumption', the vessels cut open should fill with air as the water is drained away by continued transpiration, The distribution of air-filled vessels versus distance from the cut surface should match the distribution of lengths of 'open vessels', i.e. vessels cut...

  8. A parylene-filled-trench technique for thermal isolation in silicon-based microdevices

    International Nuclear Information System (INIS)

    Lei Yinhua; Wang Wei; Li Ting; Jin Yufeng; Zhang Haixia; Li Zhihong; Yu Huaiqiang; Luo Yingcun

    2009-01-01

    Microdevices prepared in a silicon substrate have been widely used in versatile fields due to the matured silicon-based microfabrication technique and the excellent physical properties of silicon material. However, the high thermal conductivity of silicon restricts its application in most thermal microdevices, especially devices comprising different temperature zones. In this work, a parylene-filled-trench technique was optimized to realize high-quality thermal isolation in silicon-based microdevices. Parylene C, a heat transfer barricading material, was deposited on parallel high-aspect-ratio trenches, which surrounded the isolated target zones. After removing the remnant silicon beneath the trenches by deep reactive ion etching from the back side, a high-quality heat transfer barrier was obtained. By using narrow trenches, only 5 µm thick parylene was required for a complete filling, which facilitated multi-layer interconnection thereafter. The parylene filling performance inside the high-aspect-ratio trench was optimized by two approaches: multiple etch–deposition cycling and trench profile controlling. A 4 × 6 array, in which each unit was kept at a constant temperature and was well thermally isolated individually, was achieved on a silicon substrate by using the present parylene-filled-trench technique. The preliminary experimental results indicated that the present parylene-filled-trench structure exhibited excellent thermal isolation performance, with a very low power requirement of 0.134 mW (K mm 2 ) −1 for heating the isolated silicon unit and a high thermal isolation efficiency of 72.5% between two adjacent units. Accompanied with high-quality isolation performance, the microdevices embedded the present parylene-filled-trench structure to retain a strong mechanical connection larger than 400 kPa between two isolated zones, which is very important for a high-reliability-required micro-electro-mechanical-system (MEMS) device. Considering its room

  9. Full in-vitro analyses of new-generation bulk fill dental composites cured by halogen light.

    Science.gov (United States)

    Tekin, Tuçe Hazal; Kantürk Figen, Aysel; Yılmaz Atalı, Pınar; Coşkuner Filiz, Bilge; Pişkin, Mehmet Burçin

    2017-08-01

    The objective of this study was to investigate the full in-vitro analyses of new-generation bulk-fill dental composites cured by halogen light (HLG). Two types' four composites were studied: Surefill SDR (SDR) and Xtra Base (XB) as bulk-fill flowable materials; QuixFill (QF) and XtraFill (XF) as packable bulk-fill materials. Samples were prepared for each analysis and test by applying the same procedure, but with different diameters and thicknesses appropriate to the analysis and test requirements. Thermal properties were determined by thermogravimetric analysis (TG/DTG) and differential scanning calorimetry (DSC) analysis; the Vickers microhardness (VHN) was measured after 1, 7, 15 and 30days of storage in water. The degree of conversion values for the materials (DC, %) were immediately measured using near-infrared spectroscopy (FT-IR). The surface morphology of the composites was investigated by scanning electron microscopes (SEM) and atomic-force microscopy (AFM) analyses. The sorption and solubility measurements were also performed after 1, 7, 15 and 30days of storage in water. In addition to his, the data were statistically analyzed using one-way analysis of variance, and both the Newman Keuls and Tukey multiple comparison tests. The statistical significance level was established at pfill, resin-based dental composites. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Use of Gap-fills in the Buffer and Backfill of an HLW Repository

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Owan; Lee, Min Soo; Choi, Heui Joo [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The buffer and backfill are significant barrier components of the repository. They play the roles of preventing the inflow of groundwater from the surrounding rock, retarding the release of radionuclides from the waste, supporting disposal container against external impacts, and discharging decay heat from the waste. When the buffer and backfill are installed for the HLW repository, there may be gaps between the container and buffer and between the backfill and the wall of disposal tunnels, respectively. These gaps occur because spaces are allowed for ease of the installation of the buffer and backfill in excavated deposition boreholes and disposal tunnels. If the gaps are left without any sealing as they are, however, the buffer and backfill can't accomplish their functions as the barrier components. This paper reviews the gap-fill concepts of the developed foreign countries, and then suggests a gap-fill concept which is applicable for the KRS. The gap-fill is suggested to employ bentonite- based materials with a type of pellet, granule, and pellet-granule mixture. The roller compression method and extrusion-cutting method are applicable for the fabrication of the bentonite pellets which can have the high density and the required amount for use to the buffer and backfill. For the installation of the gap-fill, the pouring and then pressing method and the shotcrete- blowing method are preferable for the gap of the deposition borehole and the gap of the disposal tunnel, respectively.

  11. Technical Quality of Root Fillings Performed by Undergraduate Students: A Radiographic Study

    Directory of Open Access Journals (Sweden)

    Tatjana Vukadinov

    2014-01-01

    Full Text Available Aim. The aim of this study was to evaluate the radiographic technical quality of endodontic treatment performed by undergraduate students at the School of Dentistry, Faculty of Medicine, University of Novi Sad, Serbia. Materials and Methods. Electronic records of 220 patients treated by final-year undergraduate students during the school year 2011/2012 were examined, and the final sample consisted of 212 patients, 322 teeth, and 565 root canals. The criteria for overall radiographic adequacy of root canal fillings were defined as the presence of adequate length and density and absence of iatrogenic errors (ledge, fractured instrument, untreated canal, and apical transportation. Chi-square test was used to determine statistical significance between different parameters. Results. Adequate root canal fillings were found in 74.22% of the teeth. The percentage of root fillings with adequate length and density was 89.73% and 92.6%, respectively. Fractured instruments and ledges were present in 16 root canals (2.8%, while the presence of missed canal and apical transportation was observed in 2 cases, each (0.3%. Conclusions. Overall, the technical quality of root canal fillings performed by undergraduate students was satisfactory.

  12. Surgical sutures filled with adipose-derived stem cells promote wound healing.

    Directory of Open Access Journals (Sweden)

    Ann Katharin Reckhenrich

    Full Text Available Delayed wound healing and scar formation are among the most frequent complications after surgical interventions. Although biodegradable surgical sutures present an excellent drug delivery opportunity, their primary function is tissue fixation. Mesenchymal stem cells (MSC act as trophic mediators and are successful in activating biomaterials. Here biodegradable sutures were filled with adipose-derived mesenchymal stem cells (ASC to provide a pro-regenerative environment at the injured site. Results showed that after filling, ASCs attach to the suture material, distribute equally throughout the filaments, and remain viable in the suture. Among a broad panel of cytokines, cell-filled sutures constantly release vascular endothelial growth factor to supernatants. Such conditioned media was evaluated in an in vitro wound healing assay and showed a significant decrease in the open wound area compared to controls. After suturing in an ex vivo wound model, cells remained in the suture and maintained their metabolic activity. Furthermore, cell-filled sutures can be cryopreserved without losing their viability. This study presents an innovative approach to equip surgical sutures with pro-regenerative features and allows the treatment and fixation of wounds in one step, therefore representing a promising tool to promote wound healing after injury.

  13. High resolution neutron tomography applied to tooth fillings on real teeth by use of neutron lens

    International Nuclear Information System (INIS)

    Masschaele, B.; Cauwels, P.; Mondelaers, W.; Baechler, S.; Jolie, J.; Materna, T.

    2000-01-01

    Today tomography is a well known technique for nondestructive analysis of samples. By taking several X-ray pictures from an object, it is possible to make a 3D reconstruction. The same thing can be done with neutrons. Since very recent it is possible to produce a high-flux neutron beam. By looking at the attenuation of the neutron beam in the sample from different angles, it is possible to make a neutron tomography. The properties of neutrons are so much different from X-rays that a new era in tomography has started. Where X-rays have a hard time penetrating samples containing heavy elements (Pb, Bi, U, Hg, Au), neutrons just seem to walk through. But when the neutrons encounter samples containing light compounds like water, oil, paper, B, Li,... they are easily absorbed. This makes the use of neutrons for imaging complementary to the well known X-ray imaging. The most used tooth filling material nowadays is amalgam. Amalgam is a mixture of different metals, like silver, tin, copper, mercury. Mercury is dangerous for the human body when it enters the blood stream. These fillings are very dense and X-rays have a very hard time penetrating it. Neutrons are the ideal probe for investigation of these high density regions. The result of the tomography reveals information on the long term stability of amalgam fillings and could help the still ongoing debate on the safety of the fillings. (author)

  14. Microflora of root filled teeth with apical periodontitis in Latvian patients.

    Science.gov (United States)

    Mindere, Anda; Kundzina, Rita; Nikolajeva, Vizma; Eze, Daina; Petrina, Zaiga

    2010-01-01

    The aim of the present study was to investigate the microbial flora of root filled teeth with apical periodontitis and to determine the prevalence of β-lactamase producing strains in isolated bacteria in Latvian patients. 33 root filled teeth with asymptomatic persisting periapical lesions were selected for the present study. During nonsurgical endodontic retreatment, the root filling material was removed and canals were sampled. Determination of microbial species was based on series of biochemical tests using identification kits. All strains of bacteria were tested for β-lactamase production by using chromogenic nitrocefin-impregnated slides. Bacteria were found in 32 (97%) of initial specimens from the teeth. The number of isolated microbial strains in the specimens ranged from one to six (mean 2.7). 79% of the isolated microbial species were Gram-positive bacteria. The most common isolates were Streptococcus (27%), Actinomyces (27%), Staphylococcus (18%), Enterococcus (18%) and Lactobacillus (18%) spp. Yeasts were found as four isolates in 3 cases (9%). β-lactamase-producing bacterial strains were detected in 12 specimens, 36% of the patients. The most common enzyme-producing bacteria belonged to Actinomyces and Staphylococcus spp. The microbial flora in previously treated root canals with apical periodontitis is limited to a small number of predominantly Gram-positive microbial species. The most common isolates are Streptococcus, Actinomyces, Staphylococcus, Enterococcus and Lactobacillus spp. A moderately high prevalence of β-lactamase producing bacterial strains was detected in patients with root filled teeth with apical periodontitis.

  15. Development and characterization of hyaluronic acid-lysine nanoparticles with potential as innovative dermal filling

    Directory of Open Access Journals (Sweden)

    Jaqueline Carneiro

    Full Text Available ABSTRACT Skin aging causes changes such as wrinkles and flaccidity leading to a large demand for aesthetic procedures, including dermal filling. A key agent in dermal filling is hyaluronic acid (HA, which is a naturally occurring glycosaminoglycan. However, it is a hydrophilic macromolecule that experiences great difficulty in crossing the skin barrier causing most commercial formulations containing it to be injectable, which in turn brings risks since they involve an invasive technique. In that sense, the aim of this study was to develop and characterize nanoparticles obtained from ionic interaction between HA and lysine (Lys for use as a potential agent of dermal filling for topical application, increasing and improving its applicability and safety. To this end, nanoparticles were obtained by dripping of Lys over HA under magnetic stirring. A nanometric size was confirmed and a suitable surface charge was obtained by zeta potential. Nanoparticles were almost spherical in shape with a smooth surface. Interaction between raw materials for preparing nanoparticles was studied by FTIR and NMR spectroscopy and an ionic interaction was confirmed. These physicochemical features suggest that obtained nanoparticles can be further used as a topical dermal filling.

  16. Elaboration of metallic and composite fillings by plasma transferred arc. Process analysis and tribological study

    International Nuclear Information System (INIS)

    Rochette, Philippe

    1987-01-01

    The experimental part of this research thesis addresses the parametric study of two surface filling processes (by plasma transferred arc, and by plasma arc projection followed by a coating remelting by electron beam), the elaboration by plasma transferred arc and the metallurgical characterization of fillings of nickel base alloys and composite materials made of tungsten carbides dispersed in a nickel matrix, and the characterization of fretting wear of the so-elaborated fillings in aqueous environment. The results show that the plasma transferred arc filling technique allows coating quality and microstructure to be controlled by adjusting the mass energy of the transferred arc. Besides, this technique results in a very good control of nickel alloy coatings. The various studied composites show that it is better to use a matrix with very few alloying elements or pre-coated carbides in order to avoid any cracking phenomenon. The content of dispersed carbides must not be greater than 60 per cent in weight. The best wear behaviour is obtained with polyhedral tungsten carbides dispersed within a low alloyed nickel matrix [fr

  17. Burning test on a storage drum filled with a mixture of sodiumnitrate and bitumen

    International Nuclear Information System (INIS)

    Knotik, K.; Leichter, P.; Spalek, K.

    1979-01-01

    A burning test on a common storage drum filled with a mixture of sodiumnitrate and bitumen was carried out to show the incinerability of said mixture. A 50 l mild steel drum was filled with 80,7 kg sodiumnitrate/bitumen-mixture. The drum was packed in a 200 l mild steel drum, the remaining space was filled with enough sand to cover the top of the inner drum with 15 cm of sand. The sand packing was then soaked with 70 l of light distillate fuel and ignited. The fuel burned until self-extinguishing occurred. 30 % (22,2 l) of the fuel was burned. 0,7 % of the energy potential was absorbed in the sand layer. The highest measured temperature was 34 0 C at the top of the test drum. It can be concluded, that even under severe external actions the ignition temperature of 400 0 C for bitumen/waste mixtures cannot be reached, providing correct technical storage conditions, which means that the void space in the cavities is filled with unburnable absorbing material like sand or salt. (author)

  18. Characterization of vegetative and grain filling periods of winter wheat by stepwise regression procedure. II. Grain filling period

    Directory of Open Access Journals (Sweden)

    Pržulj Novo

    2011-01-01

    Full Text Available In wheat, rate and duration of dry matter accumulation and remobilization depend on genotype and growing conditions. The objective of this study was to determine the most appropriate polynomial regression of stepwise regression procedure for describing grain filling period in three winter wheat cultivars. The stepwise regression procedure showed that grain filling is a complex biological process and that it is difficult to offer a simple and appropriate polynomial equation that fits the pattern of changes in dry matter accumulation during the grain filling period, i.e., from anthesis to maximum grain weight, in winter wheat. If grain filling is to be represented with a high power polynomial, quartic and quintic equations showed to be most appropriate. In spite of certain disadvantages, a cubic equation of stepwise regression could be used for describing the pattern of winter wheat grain filling.

  19. Epoxy Nanocomposites filled with Carbon Nanoparticles.

    Science.gov (United States)

    Martin-Gallego, M; Yuste-Sanchez, V; Sanchez-Hidalgo, R; Verdejo, R; Lopez-Manchado, M A

    2018-01-10

    Over the past decades, the development of high performance lightweight polymer nanocomposites and, in particular, of epoxy nanocomposites has become one the greatest challenges in material science. The ultimate goal of epoxy nanocomposites is to extrapolate the exceptional intrinsic properties of the nanoparticles to the bulk matrix. However, in spite of the efforts, this objective is still to be attained at commercially attractive scales. Key aspects to achieve this are ultimately the full understanding of network structure, the dispersion degree of the nanoparticles, the interfacial adhesion at the phase boundaries and the control of the localization and orientation of the nanoparticles in the epoxy system. In this Personal Account, we critically discuss the state of the art and evaluate the strategies to overcome these barriers. © 2018 The Chemical Society of Japan & Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Bladder filling variation during radiation treatment of prostate cancer: Can the use of a bladder ultrasound scanner and biofeedback optimize bladder filling?

    International Nuclear Information System (INIS)

    Stam, Marcel R.; Lin, Emile N.J. Th. van; Vight, Lisette P. van der; Kaanders, Johannes; Visser, Andries G.

    2006-01-01

    Purpose: To investigate the use of a bladder ultrasound scanner in achieving a better reproducible bladder filling during irradiation of pelvic tumors, specifically prostate cancer. Methods and Materials: First, the accuracy of the bladder ultrasound scanner relative to computed tomography was validated in a group of 26 patients. Next, daily bladder volume variation was evaluated in a group of 18 patients. Another 16 patients participated in a biofeedback protocol, aiming at a more constant bladder volume. The last objective was to study correlations between prostate motion and bladder filling, by using electronic portal imaging device data on implanted gold markers. Results: A strong correlation between bladder scanner volume and computed tomography volume (r = 0.95) was found. Daily bladder volume variation was very high (1 Sd = 47.2%). Bladder filling and daily variation did not significantly differ between the control and the feedback group (47.2% and 40.1%, respectively). Furthermore, no linear correlations between bladder volume variation and prostate motion were found. Conclusions: This study shows large variations in daily bladder volume. The use of a biofeedback protocol yields little reduction in bladder volume variation. Even so, the bladder scanner is an easy to use and accurate tool to register these variations

  1. Geomechanical investigations for the designing of cemented filling

    Energy Technology Data Exchange (ETDEWEB)

    Berry, P.

    1980-05-15

    Laboratory and in situ investigations have led to the identification of the main geomechanical parameters that condition the stability of the cemented fill in the Gavorrano pyrite mine (Tuscany, Italy); such parameters were used for working out a satisfactory mining method. The pyrite is mined with the descending horizontal slice method with integral cemented filling which is obtained by throwing a mixture of limestone aggregates and cement into the mined voids. The laboratory geomechanical investigations carried out on fill samples have pointed out that the physical and mechanical characteristics are highly variable and this is essentially due to the fact that the fill is cast into place by compressed air. In particular, it was pointed out that the strength depends upon the cement content and upon the porosity according to a power law. The in situ measurements of the convergence between the roof and the floor, and the load measurements pointed out the considerable importance of the horizontal and vertical joints that cross the fill mass and that are inevitably brought about by a discontinuity of the fill. The results of the study made it possible to adopt an acceptable geomechanical behaviour model of the fill. On the basis of this model the mining pattern was deeply modified, the width and the height of the slices were considerably enlarged and thus the output was improved.

  2. Modeling and Fault Simulation of Propellant Filling System

    International Nuclear Information System (INIS)

    Jiang Yunchun; Liu Weidong; Hou Xiaobo

    2012-01-01

    Propellant filling system is one of the key ground plants in launching site of rocket that use liquid propellant. There is an urgent demand for ensuring and improving its reliability and safety, and there is no doubt that Failure Mode Effect Analysis (FMEA) is a good approach to meet it. Driven by the request to get more fault information for FMEA, and because of the high expense of propellant filling, in this paper, the working process of the propellant filling system in fault condition was studied by simulating based on AMESim. Firstly, based on analyzing its structure and function, the filling system was modular decomposed, and the mathematic models of every module were given, based on which the whole filling system was modeled in AMESim. Secondly, a general method of fault injecting into dynamic system was proposed, and as an example, two typical faults - leakage and blockage - were injected into the model of filling system, based on which one can get two fault models in AMESim. After that, fault simulation was processed and the dynamic characteristics of several key parameters were analyzed under fault conditions. The results show that the model can simulate effectively the two faults, and can be used to provide guidance for the filling system maintain and amelioration.

  3. Influence of filling-drawdown cycles of the Vajont reservoir on Mt. Toc slope stability

    Science.gov (United States)

    Paronuzzi, Paolo; Rigo, Elia; Bolla, Alberto

    2013-06-01

    In the present work, the 1963 Vajont landslide has been back-analyzed in detail to examine the influence of reservoir operations (filling and drawdown) on Mt. Toc slope stability. The combined seepage-slope stability analyses carried out show that the main destabilizing factor that favored the 1963 Vajont landslide was the reservoir-induced water table that formed as a consequence of rapid seepage inflow within the submerged toe of the slope — decrease in the factor of safety (FOS) up to 12% compared to the initial slope stability condition, i.e., in the absence of the Vajont reservoir. Rainfall would only have been a decisive factor if the initial stability condition of the Mt. Toc slope had already been very close to failure (decrease in FOS caused by heavy or prolonged rainfall is about 3-4%, for the worst case scenario analyzed). The permeability of the shear zone material occurring at the base of the prehistoric Vajont rockslide has been evaluated at 5 × 10- 4 m/s, and back-calculated values of the friction angles Φ range from 17.5° to 27.5°. When considering mountain reservoirs, slope failures can occur during both filling and drawdown phases. In the Vajont case, owing to the highly permeable materials of the shear zone, slope stability decreased during filling and increased during drawdown. Another displacement-dependent phenomenon of a mechanical nature - progressive failure of the NE landslide constraint - has to be considered to understand the slope collapse that occurred during the last drawdown (26 September-9 October 1963). The results of the combined seepage-slope stability models indicate that permeability of bank-forming material and filling-drawdown rates of reservoirs can strongly influence slope stability. Slow lowering of the reservoir level is a necessary measure to reduce the occurrence of very dangerous transient negative peaks of FOS.

  4. Radio resource management using geometric water-filling

    CERN Document Server

    He, Peter; Zhou, Sheng; Niu, Zhisheng

    2014-01-01

    This brief introduces the fundamental theory and development of managing radio resources using a water-filling algorithm that can optimize system performance in wireless communication. Geometric Water-Filling (GWF) is a crucial underlying tool in emerging communication systems such as multiple input multiple output systems, cognitive radio systems, and green communication systems. Early chapters introduce emerging wireless technologies and provide a detailed analysis of water-filling. The brief investigates single user and multi-user issues of radio resource management, allocation of resources

  5. Measuring Item Fill-Rate Performance in a Finite Horizon

    OpenAIRE

    Douglas J. Thomas

    2005-01-01

    The standard treatment of fill rate relies on stationary and serially independent demand over an infinite horizon. Even if demand is stationary, managers are held accountable for performance over a finite horizon. In a finite horizon, the fill rate is a random variable. Studying the distribution is relevant because a vendor may be subject to financial penalty if she fails to achieve her target fill rate over a specified finite period. It is known that for a zero lead time, base-stock model, t...

  6. Fill Rates of Single-Stage and Multistage Supply Systems

    OpenAIRE

    Matthew J. Sobel

    2004-01-01

    A supply system's fill rate is the fraction of demand that is met from on-hand inventory. This paper presents formulas for the fill rate of periodic review supply systems that use base-stock-level policies. The first part of the paper contains fill-rate formulas for a single-stage system and general distributions of demand. When demand is normally distributed, an exact expression uses only the standard normal distribution and density functions, and a good approximation uses only the standard ...

  7. Esperance: Multiple episodes of aqueous alteration involving fracture fills and coatings at Matijevic Hill, Mars

    Science.gov (United States)

    Clark, Benton C.; Morris, Richard V.; Herkenhoff, Kenneth E.; Farrand, William H.; Gellert, Ralf; Jolliff, Bradley L.; Arvidson, Raymond E.; Squyres, Steven W.; Mittelfehldt, David W.; Ming, Douglas W.; Yen, Albert S.

    2016-01-01

    In the search for evidence of past aqueous activity by the Mars Exploration Rover Opportunity, fracture-filling veins and rock coatings are prime candidates for exploration. At one location within a segment of remaining rim material surrounding Endeavour Crater, a set of “boxwork” fractures in an outcrop called Esperance are filled by a bright, hydrated, and highly siliceous (SiO2 ~ 66 wt%) material, which has overall a montmorillonite-like chemical composition. This material is partially covered by patches of a thin, dark coating that is sulfate-rich (SO3 ~ 21 wt%) but also contains significant levels of Si, Fe, Ca, and Mg. The simultaneous presence of abundant S, Si, and Fe indicates significant mineralogical complexity within the coating. This combination of vein and coating compositions is unlike previous analyses on Mars. Both materials are heterogeneously eroded, presumably by eolian abrasion. The evidence indicates at least two separate episodes of solute precipitation from aqueous fluids at this location, possibly widely separated in time. In addition to the implications for multiple episodes of alteration at the surface of the planet, aqueous chemical environments such as these would have been habitable at the time of their formation and are also favorable for preservation of organic material.

  8. Using remote sensing data to predict road fill areas and areas affected by fill erosion with planned forest road construction: a case study in Kastamonu Regional Forest Directorate (Turkey).

    Science.gov (United States)

    Aricak, Burak

    2015-07-01

    Forest roads are essential for transport in managed forests, yet road construction causes environmental disturbance, both in the surface area the road covers and in erosion and downslope deposition of road fill material. The factors affecting the deposition distance of eroded road fill are the slope gradient and the density of plant cover. Thus, it is important to take these factors into consideration during road planning to minimize their disturbance. The aim of this study was to use remote sensing and field surveying to predict the locations that would be affected by downslope deposition of eroding road fill and to compile the data into a geographic information system (GIS) database. The construction of 99,500 m of forest roads is proposed for the Kastamonu Regional Forest Directorate in Turkey. Using GeoEye satellite images and a digital elevation model (DEM) for the region, the location and extent of downslope deposition of road fill were determined for the roads as planned. It was found that if the proposed roads were constructed by excavators, the fill material would cover 910,621 m(2) and the affected surface area would be 1,302,740 m(2). Application of the method used here can minimize the adverse effects of forest roads.

  9. Cytotoxic and biological effects of bulk fill composites on rat cortical neuron cells.

    Science.gov (United States)

    Kamalak, Hakan; Kamalak, Aliye; Taghizadehghalehjoughi, Ali; Hacımüftüoğlu, Ahmet; Nalcı, Kemal Alp

    2018-03-28

    The aim of this study was to investigate potential cellular responses and biological effects of new generation dental composites on cortical neuron cells in two different exposure times. The study group included five different bulk-fill flow able composites; Surefil SDR Flow, X-tra Base Flow, Venus Bulk Flow, Filtek Bulk Flow and Tetric-Evo Flow. They were filled in Teflon molds (Height: 4 mm, Width: 6 mm) and irradiated for 20 s. Cortical neuron cells were inoculated into 24-well plates. After 80% of the wells were coated, the 3 µm membrane was inserted and dental filling materials were added. The experiment was continued for 24 and 72 h. Cell viability measured by MTT assay test, total antioxidant and total oxidant status were examined using real assay diagnostic kits. The patterns of cell death (apoptosis) were analyzed using annexin V-FITC staining with flow cytometry. Β-defensins were quantitatively assessed by RT-PCR. IL-6, IL-8 and IL-10 cytokines were measured from the supernatants. All composites significantly affected analyses parameters during the exposure durations. Our data provide evidence that all dental materials tested are cytotoxic in acute phase and these effects are induced cellular death after different exposure periods. Significant cytotoxicity was detected in TE, XB, SS, FBF and VBF groups at 24 and 72 h, respectively.

  10. Fabrication of Aluminum Tubes Filled with Aluminum Alloy Foam by Friction Welding

    Directory of Open Access Journals (Sweden)

    Yoshihiko Hangai

    2015-10-01

    Full Text Available Aluminum foam is usually used as the core of composite materials by combining it with dense materials, such as in Al foam core sandwich panels and Al-foam-filled tubes, owing to its low tensile and bending strengths. In this study, all-Al foam-filled tubes consisting of ADC12 Al-Si-Cu die-cast aluminum alloy foam and a dense A1050 commercially pure Al tube with metal bonding were fabricated by friction welding. First, it was found that the ADC12 precursor was firmly bonded throughout the inner wall of the A1050 tube without a gap between the precursor and the tube by friction welding. No deformation of the tube or foaming of the precursor was observed during the friction welding. Next, it was shown that by heat treatment of an ADC12-precursor-bonded A1050 tube, gases generated by the decomposition of the blowing agent expand the softened ADC12 to produce the ADC12 foam interior of the dense A1050 tube. A holding time during the foaming process of approximately tH = 8.5 min with a holding temperature of 948 K was found to be suitable for obtaining a sound ADC12-foam-filled A1050 tube with sufficient foaming, almost uniform pore structures over the entire specimen, and no deformation or reduction in the thickness of the tube.

  11. Interference of partial visual analysis of root filling quality and apical status on retreatment decisions

    Directory of Open Access Journals (Sweden)

    Renata Dornelles Morgental

    2012-04-01

    Full Text Available OBJECTIVE: The presence of periapical radiolucency has been used as a criterion for endodontic treatment failure. However, in addition to the inherent limitations of radiographic examinations, radiographic interpretations are extremely subjective. Thus, this study investigated the effect of partial analysis of root filling quality and periapical status on retreatment decisions by general dentists. MATERIAL AND METHODS: Twelve digitalized periapical radiographs were analyzed by 10 observers. The study was conducted at three time points at 1-week intervals. Radiographs edited with the Adobe Photoshop CS4 software were analyzed at three time points: first, only root filling quality was analyzed; second, only the periapical areas of the teeth under study were visualized; finally, observers analyzed the unedited radiographic image. Spearman ’s coefficient was used to analyze the correlations between the scores assigned when the periapical area was not visible and when the unedited radiograph was analyzed, as well as between the scores assigned when root fillings where not visible and when the unedited radiograph was analyzed. Sensitivity, specificity, positive and negative predictive values between partial images and unedited radiographs were also used to analyze retreatment decisions. The level of significance was set at 5%. RESULTS: The visualization of the root filling on the unedited radiograph affected the interpretation of the periapical status and the technical quality of the fillings has a greater influence on the general dentist’s decision to prescribe endodontic retreatment than the periapical condition. CONCLUSION: In order to make endodontic diagnosis, radiographic interpretation process should not only emphasize technical aspects, but also consider biological factors.

  12. Production of staphylococcal enterotoxin A in cream-filled cake.

    Science.gov (United States)

    Anunciaçao, L L; Linardi, W R; do Carmo, L S; Bergdoll, M S

    1995-07-01

    Cakes were baked with normal ingredients and filled with cream, inoculated with different size enterotoxigenic-staphylococcal inocula. Samples of the cakes were incubated at room temperature and put in the refrigerator. Samples of cake and filling were taken at different times and analyzed for staphylococcal count and presence of enterotoxin. The smaller the inoculum, the longer the time required for sufficient growth (10(6)) to occur for production of detectable enterotoxin. Enterotoxin added to the cake dough before baking (210 degrees C, 45 min) did not survive the baking. The presence of enterotoxin in the contaminated cream filling indicated this as the cause of staphylococcal food poisoning from cream-filled cakes. Refrigeration of the cakes prevented the growth of the staphylococci.

  13. 3D integrated HYDRA simulations of hohlraums including fill tubes

    Science.gov (United States)

    Marinak, M. M.; Milovich, J.; Hammel, B. A.; Macphee, A. G.; Smalyuk, V. A.; Kerbel, G. D.; Sepke, S.; Patel, M. V.

    2017-10-01

    Measurements of fill tube perturbations from hydro growth radiography (HGR) experiments on the National Ignition Facility show spoke perturbations in the ablator radiating from the base of the tube. These correspond to the shadow of the 10 μm diameter glass fill tube cast by hot spots at early time. We present 3D integrated HYDRA simulations of these experiments which include the fill tube. Meshing techniques are described which were employed to resolve the fill tube structure and associated perturbations in the simulations. We examine the extent to which the specific illumination geometry necessary to accommodate a backlighter in the HGR experiment contributes to the spoke pattern. Simulations presented include high resolution calculations run on the Trinity machine operated by the Alliance for Computing at Extreme Scale (ACES) partnership. This work was performed under the auspices of the Lawrence Livermore National Security, LLC, (LLNS) under Contract No. DE-AC52-07NA27344.

  14. Beeswax as dental filling on a neolithic human tooth.

    Science.gov (United States)

    Bernardini, Federico; Tuniz, Claudio; Coppa, Alfredo; Mancini, Lucia; Dreossi, Diego; Eichert, Diane; Turco, Gianluca; Biasotto, Matteo; Terrasi, Filippo; De Cesare, Nicola; Hua, Quan; Levchenko, Vladimir

    2012-01-01

    Evidence of prehistoric dentistry has been limited to a few cases, the most ancient dating back to the Neolithic. Here we report a 6500-year-old human mandible from Slovenia whose left canine crown bears the traces of a filling with beeswax. The use of different analytical techniques, including synchrotron radiation computed micro-tomography (micro-CT), Accelerator Mass Spectrometry (AMS) radiocarbon dating, Infrared (IR) Spectroscopy and Scanning Electron Microscopy (SEM), has shown that the exposed area of dentine resulting from occlusal wear and the upper part of a vertical crack affecting enamel and dentin tissues were filled with beeswax shortly before or after the individual's death. If the filling was done when the person was still alive, the intervention was likely aimed to relieve tooth sensitivity derived from either exposed dentine and/or the pain resulting from chewing on a cracked tooth: this would provide the earliest known direct evidence of therapeutic-palliative dental filling.

  15. Beeswax as dental filling on a neolithic human tooth.

    Directory of Open Access Journals (Sweden)

    Federico Bernardini

    Full Text Available Evidence of prehistoric dentistry has been limited to a few cases, the most ancient dating back to the Neolithic. Here we report a 6500-year-old human mandible from Slovenia whose left canine crown bears the traces of a filling with beeswax. The use of different analytical techniques, including synchrotron radiation computed micro-tomography (micro-CT, Accelerator Mass Spectrometry (AMS radiocarbon dating, Infrared (IR Spectroscopy and Scanning Electron Microscopy (SEM, has shown that the exposed area of dentine resulting from occlusal wear and the upper part of a vertical crack affecting enamel and dentin tissues were filled with beeswax shortly before or after the individual's death. If the filling was done when the person was still alive, the intervention was likely aimed to relieve tooth sensitivity derived from either exposed dentine and/or the pain resulting from chewing on a cracked tooth: this would provide the earliest known direct evidence of therapeutic-palliative dental filling.

  16. New Approach in Filling of Fixed-Point Cells: Case Study of the Melting Point of Gallium

    Science.gov (United States)

    Bojkovski, J.; Hiti, M.; Batagelj, V.; Drnovšek, J.

    2008-02-01

    The typical way of constructing fixed-point cells is very well described in the literature. The crucible is loaded with shot, or any other shape of pure metal, inside an argon-filled glove box. Then, the crucible is carefully slid into a fused-silica tube that is closed at the top with an appropriate cap. After that, the cell is removed from the argon glove box and melted inside a furnace while under vacuum or filled with an inert gas like argon. Since the metal comes as shot, or in some other shape such as rods of various sizes, and takes more volume than the melted material, it is necessary to repeat the procedure until a sufficient amount of material is introduced into the crucible. With such a procedure, there is the possibility of introducing additional impurities into the pure metal with each cycle of melting the material and putting it back into the glove box to fill the cell. Our new approach includes the use of a special, so-called dry-box system, which is well known in chemistry. The atmosphere inside the dry box contains less than 20 ppm of water and less than 3 ppm of oxygen. Also, the size of the dry box allows it to contain a furnace for melting materials, not only for gallium but for higher-temperature materials as well. With such an approach, the cell and all its parts (pure metal, graphite, fused-silica tube, and cap) are constantly inside the controlled atmosphere, even while melting the material and filling the crucible. With such a method, the possibility of contaminating the cell during the filling process is minimized.

  17. The quantum Hall effect at 5/2 filling factor

    International Nuclear Information System (INIS)

    Willett, R L

    2013-01-01

    Experimental discovery of a quantized Hall state at 5/2 filling factor presented an enigmatic finding in an established field of study that has remained an open issue for more than twenty years. In this review we first examine the experimental requirements for observing this state and outline the initial theoretical implications and predictions. We will then follow the chronology of experimental studies over the years and present the theoretical developments as they pertain to experiments, directed at sets of issues. These topics will include theoretical and experimental examination of the spin properties at 5/2; is the state spin polarized? What properties of the higher Landau levels promote development of the 5/2 state, what other correlation effects are observed there, and what are their interactions with the 5/2 state? The 5/2 state is not a robust example of the fractional quantum Hall effect: what experimental and material developments have allowed enhancement of the effect? Theoretical developments from initial pictures have promoted the possibility that 5/2 excitations are exceptional; do they obey non-abelian statistics? The proposed experiments to determine this and their executions in various forms will be presented: this is the heart of this review. Experimental examination of the 5/2 excitations through interference measurements will be reviewed in some detail, focusing on recent results that demonstrate consistency with the picture of non-abelian charges. The implications of this in the more general physics picture is that the 5/2 excitations, shown to be non-abelian, should exhibit the properties of Majorana operators. This will be the topic of the last review section. (review article)

  18. Simulation of mould filling process for composite skeleton castings

    OpenAIRE

    M. Dziuba; M. Cholewa

    2008-01-01

    In this work authors showed selected results of simulation and experimental studies on temperature distribution during solidification of skeleton casting and mould filling process. The aim of conducted simulations was the choice of thermal and geometrical parameters for the needs of designed calculations of the skeleton castings and the estimation of the guidelines for the technology of manufacturing. The subject of numerical simulation was the analysis of ability of filling the channels of c...

  19. Method for filling a reactor with a catalyst

    DEFF Research Database (Denmark)

    2013-01-01

    The invention relates to a method for filling a reactor with a catalyst for the carbonylation of carbonylated compounds in the gas phase. According to said method, a SILP catalyst is covered with a filling agent which is liquid under normal conditions and is volatile under carbonylation reaction...... conditions, and a thus-treated catalyst is introduced into the reactor and the reactor is sealed....

  20. Countering Stryker’s Punch: Algorithmically Filling the Black Hole

    OpenAIRE

    Michael J. Bennett

    2017-01-01

    Two current digital image editing programs are examined in the context of filling in missing visual image data from hole-punched United States Farm Security Administration (FSA) negatives. Specifically, Photoshop's Content-Aware Fill feature and GIMP's Resynthesizer plugin are evaluated and contrasted against comparable images. A possible automated workflow geared towards large scale editing of similarly hole-punched negatives is also explored. Finally, potential future research based upon th...