WorldWideScience

Sample records for room shielding design

  1. Shield design of concrete wall between decay tank room and primary pump room in TRIGA facility

    International Nuclear Information System (INIS)

    Khan, M. J. H.; Rahman, M.; Haque, A.; Zulquarnain, A.; Ahmed, F. U.; Bhuiyan, S. I.

    2007-01-01

    The objective of this study is to recommend the radiation protection design parameters from the shielding point of view for concrete wall between the decay tank room and the primary pump room in TRIGA Mark-II research reactor facility. The shield design for this concrete wall has been performed with the help of Point-kernel Shielding Code Micro-Shield 5.05 and this design was also validated based on the measured dose rate values with Radiation Survey Meter (G-M Counter) considering the ICRP-60 (1990) recommendations for occupational dose rate limit (10 μSv/hr). The recommended shield design parameters are: (i) thickness of 114.3 cm Ilmenite-Magnetite Concrete (IMC) or 129.54 cm Ordinary Reinforced Concrete (ORC) for concrete wall A (ii) thickness of 66.04 cm Ilmenite-Magnetite Concrete (IMC) or 78.74 cm Ordinary Reinforced Concrete (ORC) for concrete wall B and (iii) door thickness of 3.175 cm Mild Steel (MS) on the entrance of decay tank room. In shielding efficiency analysis, the use of I-M concrete in the design of this concrete wall shows that it reduced the dose rate by a factor of at least 3.52 times approximately compared to ordinary reinforced concrete

  2. Shielding design for the target room of the proton accelerator research center

    International Nuclear Information System (INIS)

    Min, Y. S.; Lee, C. W.; Mun, K. J.; Nam, J.; Kim, J. Y.

    2010-01-01

    The Proton Engineering Frontier Project (PEFP) has been developing a 100-MeV proton linear accelerator. Also, PEFP has been designing the Proton Accelerator Research Center (PARC). In the Accelerator Tunnel and Beam Experiment Hall in PARC, 10 target rooms for the 20- and 100-MeV beamline facilities exist in the Beam Experiment Hall. For the 100-MeV target rooms during 100-MeV proton beam extraction, a number of high energy neutrons, ranging up to 100-MeV, are produced. Because of the high beam current and space limitations of each target room, the shielding design of each target room should be considered seriously. For the shielding design of the 100-MeV target rooms of the PEFP, a permanent and removable local shield structure was adopted. To optimize shielding performance, we evaluated four different shield materials (concrete, HDPE, lead, iron). From the shielding calculation results, we confirmed that the proposed shielding design made it possible to keep the dose rate below the 'as low as reasonably achievable (ALARA)' objective.

  3. Shielding design for testing room of large container scanner

    International Nuclear Information System (INIS)

    Liu Yisi; Miao Qitian; Zhou Liye

    1997-01-01

    Testing facility for large container scanner is a most advanced anti-smuggle tool. The X-ray scanning principle is adopted in this system. The X-ray was collimated a ted as a fan-shape beam. The accelerator only supplies the ray beam when the container is scanned. The irradiation time is less than one minute per test. The X-ray burst irradiation and highly collimated a ted scanning beam of this system is different from the common industrial irradiation accelerator. The shielding design of the 1:1 large container scanner introduced has better collimation level because of tri-collimation. The irradiation dose is less than 150 μGy per test, which is obviously lower than importations

  4. Radiation shielding design of BNCT treatment room for D-T neutron source.

    Science.gov (United States)

    Pouryavi, Mehdi; Farhad Masoudi, S; Rahmani, Faezeh

    2015-05-01

    Recent studies have shown that D-T neutron generator can be used as a proper neutron source for Boron Neutron Capture Therapy (BNCT) of deep-seated brain tumors. In this paper, radiation shielding calculations have been conducted based on the computational method for designing a BNCT treatment room for a recent proposed D-T neutron source. By using the MCNP-4C code, the geometry of the treatment room has been designed and optimized in such a way that the equivalent dose rate out of the treatment room to be less than 0.5μSv/h for uncontrolled areas. The treatment room contains walls, monitoring window, maze and entrance door. According to the radiation protection viewpoint, dose rate results of out of the proposed room showed that using D-T neutron source for BNCT is safe. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Shielding Design and Leaking Measurement for the High Energy Radiation Room

    International Nuclear Information System (INIS)

    Chu, Sung Sil

    1979-01-01

    An optimum shielding design and the computation of protective barriers for high energy radiation therapy room, Toshiba 13 MeV , are presented. We obtained following results by comparison between the p recalculating values and actual survey after complete installation of radio generating units. 1. The precalculating values of protective barrier are 5 times more protective than that of actual measurement. 2. The dose rate during exposure are 2-10 mR /hr at out of the door and the control room. 3. The exposure doses for occupationally persons are relatively low levels, the average values of exposure dose is 10-50 mR per month. 4. The foul smelling and ozone gas production from long exposure of cancer patients cannot be eliminated when the room is ill ventilated

  6. Simple Design Method for Magnetic Shield Room(The 20th MAGDA Conference in Pacific Asia (MAGDA2011))

    OpenAIRE

    Keisuke, FUJISAKI; Masahiro, FUJIKURA; Jirou, MINO; Nippon Steel Corporation:Toyota Technological Institute; Nippon Steel Corporation; Nippon Steel Engineering Co., Ltd

    2012-01-01

    As a primary evaluation of the magnetic shield room design, a simple design method is proposed here. The steel sheet number of the magnetic shield room is designed so as to make the distributed magnetic flux density from the exciting coil catch the magnetic shield body. The proposed method is applied to a full-scale magnetic shield room and the leakage magnetic flux density is evaluated by numerical calculation. Though it introduces a large steel number of the magnetic shield body, the leakag...

  7. Shielded room measurements, Final report

    Energy Technology Data Exchange (ETDEWEB)

    Stanton, J.S.

    1949-02-22

    The attenuation of electro-statically and electro-magnetically shielded rooms in the ``E,`` ``R,`` ``I,`` and ``T`` Buildings was measured so that corrective measure could be taken if the attenuation was found to be low. If remedial measures could not be taken, the shortcomings of the rooms would be known. Also, the men making the measurements should oversee construction and correct errors at the time. The work was performed by measuring the attenuation at spot frequencies over the range of from 150 kilocycles to 1280 megacycles with suitable equipment mounted in small rubber-tried trucks. The attenuation was determined by ``before and after`` shielding and/or ``door open and door closed`` measurements after installation of copper shielding. In general, attenuation in the frequency range of approximately 10 to 150 mc. was good and was of the order expected. At frequencies in the range of 150 mc. to 1280 mc., the attenuation curve was more erratic; that is, at certain frequencies a severe loss of attenuation was noted, while at others, the attenuation was very good. This was mainly due to poor or faulty seals around doors and pass windows. These poor seals existed in the ``T,`` ``E,`` and ``I`` Buildings because the doors were fitted improperly and somewhat inferior material was used. By experience from these difficulties, both causes were corrected in the ``R`` Building, which resulted in the improvement of the very high frequency (v.h.f.) range in this building. In some specific cases, however, the results were about the same. For the range of frequencies below approximately 10 mc., the attenuation, in almost all cases, gradually decreased as the frequency decreased and reached a minimum at .3 to 1.0 mc. This loss of attenuation was attributed to multiple grounding caused by moisture in the insulating timbers and will gradually decrease as the wood dries out.

  8. Design of emergency shield

    International Nuclear Information System (INIS)

    Soliman, S.E.

    1993-01-01

    Manufacturing of an emergency movable shield in the hot laboratories center is urgently needed for the safety of personnel in case of accidents or spilling of radioactive materials. In this report, a full design for an emergency shield is presented and the corresponding dose rates behind the shield for different activities (from 1 mCi to 5 Ci) was calculated by using micro shield computer code. 4 figs., 1 tab

  9. Shielding design of a treatment room for an accelerator-based epithermal neutron irradiation facility for BNCT

    International Nuclear Information System (INIS)

    Evans, J.F.; Blue, T.E.

    1996-01-01

    Protecting the facility personnel and the general public from radiation exposure is a primary safety concern of an accelerator-based epithermal neutron irradiation facility. This work makes an attempt at answering the questions open-quotes How much?close quotes and open-quotes What kind?close quotes of shielding will meet the occupational limits of such a facility. Shielding effectiveness is compared for ordinary and barytes concretes in combination with and without borated polyethylene. A calculational model was developed of a treatment room, patient open-quotes scatterer,close quotes and the epithermal neutron beam. The Monte Carlo code, MCNP, was used to compute the total effective dose equivalent rates at specific points of interest outside of the treatment room. A conservative occupational effective dose rate limit of 0.01 mSv h -1 was the guideline for this study. Conservative Monte Carlo calculations show that constructing the treatment room walls with 1.5 m of ordinary concrete, 1.2 m of barytes concrete, 1.0 m of ordinary concrete preceded by 10 cm of 5% boron-polyethylene, or 0.8 m of barytes concrete preceded by 10 cm of 5% boron-polyethylene will adequately protect facility personnel. 20 refs., 8 figs., 2 tabs

  10. Shielding calculation for treatment rooms of high energy linear accelerator

    International Nuclear Information System (INIS)

    Elleithy, M.A.

    2006-01-01

    A review of German Institute of Standardization (DIN) scheme of the shielding calculation and the essential data required has been done for X-rays and electron beam in the energy range from 1 MeV to 50 MeV. Shielding calculation was done for primary and secondary radiations generated during X-ray operation of Linac. In addition, shielding was done against X-rays generated (Bremsstrahlung) by useful electron beams. The calculations also covered the neutrons generated from the interactions of useful X-rays (at energies above 8 MeV) with the surrounding. The present application involved the computation of shielding against the double scattered components of X-rays and neutrons in the maze area and the thickness of the paraffin wax of the room door. A new developed computer program was designed to assist shielding thickness calculations for a new Linac installation or in replacing an existing machine. The program used a combination of published tables and figures in computing the shielding thickness at different locations for all possible radiation situations. The DIN published data of 40 MeV accelerator room was compared with the program calculations. It was found that there is good agreement between both calculations. The developed program improved the accuracy and speed of calculation

  11. Computer code for shielding calculations of x-rays rooms

    International Nuclear Information System (INIS)

    Affonso, R.R.W.; Borges, D. da S.; Lava, D.D.; Moreira, M. de L.; Guimarães, A.C.F.

    2015-01-01

    The building an effective barrier against ionizing radiation present in radiographic rooms requires consideration of many variables. The methodology used for thickness specification of primary and secondary, barrier of a traditional radiographic room, considers the following factors: Use Factor, Occupational Factor, distance between the source and the wall, Workload, Kerma in the air and distance between the patient and the source. With these data it was possible to develop a computer code, which aims to identify and use variables in functions obtained through graphics regressions provided by NCRP-147 (Structural Shielding Design for Medical X-Ray Imaging Facilities) report, for shielding calculation of room walls, and the walls of the dark room and adjacent areas. With the implemented methodology, it was made a code validation by comparison of results with a study case provided by the report. The obtained values for thickness comprise different materials such as concrete, lead and glass. After validation it was made a case study of an arbitrary radiographic room.The development of the code resulted in a user-friendly tool for planning radiographic rooms to comply with the limits established by CNEN-NN-3:01 published in september/2011. (authors)

  12. Evaluation of the shielding of a room for radiodiagnostic

    International Nuclear Information System (INIS)

    Padilla R, Z. P.; Acuna D, E.; Escareno J, E.; Vega C, H. R.

    2011-10-01

    The X-ray discovery by Roentgen in 1895 and its application in diagnosis was a breakthrough in medicine. Worldwide, X-ray technique is one of the most widely used procedures in medical diagnosis. At the Mental Health Hospital of Calera Zacatecas a room has been designed as radiology room, however there is not a record of shielding characteristics. In order to determine the features of X-ray equipment that the room can host, in this work a series of calculations were carried out. Calculations were based upon the NCRP 151 recommendations and fulfilling the requirements given in the Mexican standard NOM-229-SSA1-2002. From the actual room conditions this can host a X-ray equipment without fluoroscopy, with a workload of 80 ma-min/week, with 125 k Vp as maximum operating voltage. From the actual conditions a set of recommendations, for better protection of radiation workers and public are also given. (Author)

  13. New Toroid shielding design

    CERN Multimedia

    Hedberg V

    On the 15th of June 2001 the EB approved a new conceptual design for the toroid shield. In the old design, shown in the left part of the figure above, the moderator part of the shielding (JTV) was situated both in the warm and cold areas of the forward toroid. It consisted both of rings of polyethylene and hundreds of blocks of polyethylene (or an epoxy resin) inside the toroid vacuum vessel. In the new design, shown to the right in the figure above, only the rings remain inside the toroid. To compensate for the loss of moderator in the toroid, the copper plug (JTT) has been reduced in radius so that a layer of borated polyethylene can be placed around it (see figure below). The new design gives significant cost-savings and is easier to produce in the tight time schedule of the forward toroid. Since the amount of copper is reduced the weight that has to be carried by the toroid is also reduced. Outgassing into the toroid vacuum was a potential problem in the old design and this is now avoided. The main ...

  14. Radiation shielding and safety design

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Ouk; Gil, C. S.; Cho, Y. S.; Kim, D. H.; Kim, H. I.; Kim, J. W.; Lee, C. W.; Kim, K. Y.; Kim, B. H. [KAERI, Daejeon (Korea, Republic of)

    2011-07-15

    A benchmarking for the test facility, evaluations of the prompt radiation fields, evaluation of the induced activities in the facility, and estimation of the radiological impact on the environment were performed in this study. and the radiation safety analysis report for nuclear licensing was written based on this study. In the benchmark calculation, the neutron spectra was measured in the 20 Mev test facility and the measurements were compared with the computational results to verify the calculation system. In the evaluation of the prompt radiation fields, the shielding design for 100 MeV target rooms, evaluations of the leakage doses from the accidents and skyshine analysis were performed. The evaluation of the induced activities were performed for the coolant, inside air, structural materials, soil and ground-water. At last, the radiation safety analysis report was written based on results from these studies

  15. Design experience: CRBRP radiation shielding

    International Nuclear Information System (INIS)

    Disney, R.K.; Chan, T.C.; Gallo, F.G.; Hedgecock, L.R.; McGinnis, C.A.; Wrights, G.N.

    1978-11-01

    The Clinch River Breeder Reactor Plant (CRBRP) is being designed as a fast breeder demonstration project in the U.S. Liquid Metal Fast Breeder Reactor (LMFBR) program. Radiation shielding design of the facility consists of a comprehensive design approach to assure compliance with design and government regulatory requirements. Studies conducted during the CRBRP design process involved the aspects of radiation shielding dealing with protection of components, systems, and personnel from radiation exposure. Achievement of feasible designs, while considering the mechanical, structural, nuclear, and thermal performance of the component or system, has required judicious trade-offs in radiation shielding performance. Specific design problems which have been addressed are in-vessel radial shielding to protect permanent core support structures, flux monitor system shielding to isolate flux monitoring systems for extraneous background sources, reactor vessel support shielding to allow personnel access to the closure head during full power operation, and primary heat transport system pipe chaseway shielding to limit intermediate heat transport system sodium system coolant activation. The shielding design solutions to these problems defined a need for prototypic or benchmark experiments to provide assurance of the predicted shielding performance of selected design solutions and the verification of design methodology. Design activities of CRBRP plant components an systems, which have the potential for radiation exposure of plant personnel during operation or maintenance, are controlled by a design review process related to radiation shielding. The program implements design objectives, design requirements, and cost/benefit guidelines to assure that radiation exposures will be ''as low as reasonably achievable''

  16. Neutron shield analysis and design for the PDX fusion facility

    International Nuclear Information System (INIS)

    Grimesey, R.A.; Nigg, D.W.; Scott, A.J.; Wheeler, F.J.; Jassby, D.L.; Perry, E.D.

    1979-01-01

    The basic component of the biological shield for PDX is an existing 81 cm thick high-density concrete shielding wall surrounding the machine. The principal additional shielding requirement is a roof shield over the machine to reduce air-scattered skyshine dose into the PDX control room and to the site boundary. The roof shield is designed in removable sections on a steel support structure permitting overhead crane access to major PDX components. After analysis of a number of alternate concepts, a roof shield consisting of 50 cm of water in polyethylene tanks was selected to meet design objectives of effectiveness, weight, removability, and cost

  17. Radiation protection/shield design

    International Nuclear Information System (INIS)

    Disney, R.K.

    1977-01-01

    Radiation protection/shielding design of a nuclear facility requires a coordinated effort of many engineering disciplines to meet the requirements imposed by regulations. In the following discussion, the system approach to Clinch River Breeder Reactor Plant (CRBRP) radiation protection will be described, and the program developed to implement this approach will be defined. In addition, the principal shielding design problems of LMFBR nuclear reactor systems will be discussed in realtion to LWR nuclear reactor system shielding designs. The methodology used to analyze these problems in the U.S. LMFBR program, the resultant design solutions, and the experimental verification of these designs and/or methods will be discussed. (orig.) [de

  18. Structural shielding of medical X-ray rooms for diagnostic installations

    International Nuclear Information System (INIS)

    Rabitsch, H.

    1979-06-01

    In Part I (RIG 8), the various design procedures for shielding against X-rays are discussed and compared. In particular, this comparison is carried out between the shielding obtained conforming to the Austrian Regulations for Radiation Protection and that obtained from the DIN-standard DIN 6812; this latter includes the various operating conditions of diagnostic installations up to 150 kV. Several examples for particular structural shielding components in medical radiation rooms are given. (author)

  19. A versatile program for the calculation of linear accelerator room shielding.

    Science.gov (United States)

    Hassan, Zeinab El-Taher; Farag, Nehad M; Elshemey, Wael M

    2018-03-22

    This work aims at designing a computer program to calculate the necessary amount of shielding for a given or proposed linear accelerator room design in radiotherapy. The program (Shield Calculation in Radiotherapy, SCR) has been developed using Microsoft Visual Basic. It applies the treatment room shielding calculations of NCRP report no. 151 to calculate proper shielding thicknesses for a given linear accelerator treatment room design. The program is composed of six main user-friendly interfaces. The first enables the user to upload their choice of treatment room design and to measure the distances required for shielding calculations. The second interface enables the user to calculate the primary barrier thickness in case of three-dimensional conventional radiotherapy (3D-CRT), intensity modulated radiotherapy (IMRT) and total body irradiation (TBI). The third interface calculates the required secondary barrier thickness due to both scattered and leakage radiation. The fourth and fifth interfaces provide a means to calculate the photon dose equivalent for low and high energy radiation, respectively, in door and maze areas. The sixth interface enables the user to calculate the skyshine radiation for photons and neutrons. The SCR program has been successfully validated, precisely reproducing all of the calculated examples presented in NCRP report no. 151 in a simple and fast manner. Moreover, it easily performed the same calculations for a test design that was also calculated manually, and produced the same results. The program includes a new and important feature that is the ability to calculate required treatment room thickness in case of IMRT and TBI. It is characterised by simplicity, precision, data saving, printing and retrieval, in addition to providing a means for uploading and testing any proposed treatment room shielding design. The SCR program provides comprehensive, simple, fast and accurate room shielding calculations in radiotherapy.

  20. Double-layer neutron shield design as neutron shielding application

    Science.gov (United States)

    Sariyer, Demet; Küçer, Rahmi

    2018-02-01

    The shield design in particle accelerators and other high energy facilities are mainly connected to the high-energy neutrons. The deep penetration of neutrons through massive shield has become a very serious problem. For shielding to be efficient, most of these neutrons should be confined to the shielding volume. If the interior space will become limited, the sufficient thickness of multilayer shield must be used. Concrete and iron are widely used as a multilayer shield material. Two layers shield material was selected to guarantee radiation safety outside of the shield against neutrons generated in the interaction of the different proton energies. One of them was one meter of concrete, the other was iron-contained material (FeB, Fe2B and stainless-steel) to be determined shield thicknesses. FLUKA Monte Carlo code was used for shield design geometry and required neutron dose distributions. The resulting two layered shields are shown better performance than single used concrete, thus the shield design could leave more space in the interior shielded areas.

  1. Shielding Design and Radiation Shielding Evaluation for LSDS System Facility

    International Nuclear Information System (INIS)

    Kim, Younggook; Kim, Jeongdong; Lee, Yongdeok

    2015-01-01

    As the system characteristics, the target in the spectrometer emits approximately 1012 neutrons/s. To efficiently shield the neutron, the shielding door designs are proposed for the LSDS system through a comparison of the direct shield and maze designs. Hence, to guarantee the radiation safety for the facility, the door design is a compulsory course of the development of the LSDS system. To improve the shielding rates, 250x250 covering structure was added as a subsidiary around the spectrometer. In this study, the evaluations of the suggested shielding designs were conducted using MCNP code. The suggested door design and covering structures can shield the neutron efficiently, thus all evaluations of all conditions are satisfied within the public dose limits. From the Monte Carlo code simulation, Resin(Indoor type) and Tungsten(Outdoor type) were selected as the shielding door materials. From a comparative evaluation of the door thickness, In and Out door thickness was selected 50 cm

  2. Pre-installation empirical testing of room shielding for high dose rate remote afterloaders

    International Nuclear Information System (INIS)

    Klein, E.E.; Grigsby, P.W.; Williamson, J.F.; Meigooni, A.S.

    1993-01-01

    PURPOSE: Many facilities are acquiring high dose rate remote afterloading units. It is economical that these units be placed in existing shielded teletherapy rooms. Scatter-radiation barriers marginally protect uncontrolled areas from a high dose rate source especially in a room that houses a non-dynamic Cobalt-60 unit. In addition the exact thickness and material composition of the barriers are unknown and therefore, a calculation technique may give misleading results. Also, it would be impossible to evaluate an entire wall barrier by taking isolated core samples in order to assist in the calculations. A quick and inexpensive measurement of dose equivalent using a rented high activity 192Ir source evaluates the barriers and locates shielding deficiencies. METHODS AND MATERIALS: We performed transmission calculations for primary and scattered radiation based on National Council on Radiation Protection and Measurements Reports 49 and 51, respectively. We then rented a high activity 21.7 Ci (8.03 x 10(11) Bq) Ir-192 source to assess our existing teletherapy room shielding for adequacy and voids. This source was placed at the proposed location for clinical high dose rate treatment and measurements were performed. RESULTS: No deficiencies were found in controlled areas surrounding the room, but large differences were found between the calculated and measured values. Our survey located a region in the uncontrolled area above the room requiring augmented shielding which was not predicted by the calculations. A canopy shield was designed to potentially augment the shielding in the ceiling direction. CONCLUSION: Pre-installation testing by measurement is an invaluable method for locating shielding deficiencies and avoiding unnecessary enhancement of shielding particularly when there is lack of information of the inherent shielding

  3. Control room design

    International Nuclear Information System (INIS)

    Zinke, H.

    1980-01-01

    To control a 1300 megawatt nuclear power plant, about 15000 plant parameters must be collected together to control and operate the plant. The control room design therefore is of particular importance. The main design criteria are: Required functions of the power plant process - Level of Automation - Ergonomics - Available Technology. Extensive analysis has resulted in a control room design method. This ensures that an objective solution will be reached. Resulting from this methodical approach are: 1. Scope, position and appearance of the instrumentation. 2. Scope, position and appearance of the operator controls. Process analysis dictates what instrumentation and operator controls are needed. The priority and importance of the control and instrumentation (this we define as the utilisation areas), dictates the rough layout of the control room. (orig./RW)

  4. Design report for shielded glove box

    International Nuclear Information System (INIS)

    Ku, J. H.; Lee, J. C.; Seo, K. S.; Bang, K. S.; Lee, D. W.; Kim, J. H.; Min, D. K.; Park, S. W.

    1999-05-01

    For the examination of spent fuels and high radioactive specimens using a specially equipped scanning electron microscope, a shielded glove box was designed and constructed at PIE facility of KAERI. This glove box consisted of shielding walls, containment box, lead glasses, manipulators, gloves, ventilation systems, doors, hot-cell specimen cask adapter, etc. It was emphasized that both the easy operation and radiation safety are important factors in the shielded glove box were installed also considered as a important factor to build the basic concept of the assembling. Two sliding doors and one hinge-type door were installed for the easy installation, operation and maintenance of scanning electron microscope. Containment box which confines the radioactive material into the box consisted of reinforced transparent glasses, aluminum frames and stainless steel plate liner. Therefore everything beyond the containment box can be seen through the lead glass which installed at the front shielding wall. All shielding walls and doors were introduced separately into the room and assembled by bolting. (author). 3 refs., 5 tabs., 18 figs

  5. Spectroscopic Study of Radiation around the Leksell Gamma Knife for Room Shielding Applications

    OpenAIRE

    Hubert, Alexis

    2017-01-01

    Any center planning to install a Gamma Knife radiosurgery unit has to provide for an efficient shielding of the treatment room, to protect the patient, the staff and the public, against undesired radiation. The shielding barrier design is controlled by national and international recommendations; the reference documents for gamma ray radiotherapy facilities are the National Council on Radiation Protection and Measurements (NCRP) reports 49 and 151. However, some facts highlighted in this thesi...

  6. Some folded issues related to over-shielded and unplanned rooms for medical linear accelerators - A case study

    Science.gov (United States)

    Muhammad, Wazir; Ullah, Asad; Hussain, Amjad; Ali, Nawab; Alam, Khan; Khan, Gulzar; Matiullah; Maeng, Seongjin; Lee, Sang Hoon

    2015-08-01

    A medical linear accelerator (LINAC) room must be properly shielded to limit the outside radiation exposure to an acceptable safe level defined by individual state and international regulations. However, along with this prime objective, some additional issues are also important. The current case-study was designed to unfold the issues related to over-shielded and unplanned treatment rooms for LINACs. In this connection, an apparently unplanned and over-shielded treatment room of 610 × 610 cm2 in size was compared with a properly designed treatment room of 762 × 762 cm2 in size ( i.e., by following the procedures and recommendations of the IAEA Safety Reports Series No. 47 and NCRP 151). Evaluation of the unplanned room indicated that it was over-shielded and that its size was not suitable for total body irradiation (TBI), although the license for such a treatment facility had been acquired for the installed machine. An overall 14.96% reduction in the total shielding volume ( i.e., concrete) for an optimally planned room as compared to a non-planned room was estimated. Furthermore, the inner room's dimensions were increased by 25%, in order to accommodate TBI patients. These results show that planning and design of the treatment rooms are imperative to avoid extra financial burden to the hospitals and to provide enough space for easy and safe handling of the patients. A spacious room is ideal for storing treatment accessories and facilitates TBI treatment.

  7. New facility shield design criteria

    International Nuclear Information System (INIS)

    Howell, W.P.

    1981-07-01

    The purpose of the criteria presented here is to provide standard guidance for the design of nuclear radiation shields thoughout new facilities. These criteria are required to assure a consistent and integrated design that can be operated safely and economically within the DOE standards. The scope of this report is confined to the consideration of radiation shielding for contained sources. The whole body dose limit established by the DOE applies to all doses which are generally distributed throughout the trunk of the body. Therefore, where the whole body is the critical organ for an internally deposited radionuclide, the whole body dose limit applies to the sum of doses received must assure control of the concentration of radionuclides in the building atmosphere and thereby limit the dose from internal sources

  8. MMW [multimegawatt] shielding design and analysis

    International Nuclear Information System (INIS)

    Olson, A.P.

    1988-01-01

    Reactor shielding for multimegawatt (MMW) space power must satisfy a mass constraint as well as performance specifications for neutron fluence and gamma dose. A minimum mass shield is helpful in attaining the launch mass goal for the entire vehicle, because the shield comprises about 1% to 2% of the total vehicle mass. In addition, the shield internal heating must produce tolerable temperatures. The analysis of shield performance for neutrons and gamma rays is emphasized. Topics addressed include cross section preparation for multigroup 2D S/sub n/-transport analyses, and the results of parametric design studies on shadow shield performance and mass versus key shield design variables such as cone angle, number, placement, and thickness of layers of tungsten, and shield top radius. Finally, adjoint methods are applied to the shield in order to spatially map its relative contribution to dose reduction, and to provide insight into further design optimization. 7 refs., 2 figs., 3 tabs

  9. Concrete mix design for X-and gamma shielding

    International Nuclear Information System (INIS)

    Mohamad Pauzi Ismail; Noor Azreen Masenwat; Suhairy Sani; Abdul Bakhri Muhammad; Mohd Kamal Shah Shamsuddin; Rahmad Abd Rashid

    2012-01-01

    The design of X-ray or gamma ray radiographic exposure room requires some calculations on shielding to provide safe operation of the facility and minimum exposure to radiation workers. Careful design can lead to economical installations with minimal barriers. The design depends on such factors as: maximum energy, maximum intensity, permitted full-body dosage, workload, use factor, occupancy factor, maximum dose output and shielding materials. Choice of material for a barrier depends on convenience and cost. The radiographic exposure room is usually made of normal concrete with density of about 2.3 - 2.4 g/ cc. Normal concrete is often used for construction of exposure room because of cheap and ease of construction. This paper explained and discussed the optimum mix design for normal concrete used for X-and gamma shielding. (author)

  10. RadShield: semiautomated shielding design using a floor plan driven graphical user interface.

    Science.gov (United States)

    DeLorenzo, Matthew C; Wu, Dee H; Yang, Kai; Rutel, Isaac B

    2016-09-08

    The purpose of this study was to introduce and describe the development of RadShield, a Java-based graphical user interface (GUI), which provides a base design that uniquely performs thorough, spatially distributed calculations at many points and reports the maximum air-kerma rate and barrier thickness for each barrier pursuant to NCRP Report 147 methodology. Semiautomated shielding design calculations are validated by two approaches: a geometry-based approach and a manual approach. A series of geometry-based equations were derived giv-ing the maximum air-kerma rate magnitude and location through a first derivative root finding approach. The second approach consisted of comparing RadShield results with those found by manual shielding design by an American Board of Radiology (ABR)-certified medical physicist for two clinical room situations: two adjacent catheterization labs, and a radiographic and fluoroscopic (R&F) exam room. RadShield's efficacy in finding the maximum air-kerma rate was compared against the geometry-based approach and the overall shielding recommendations by RadShield were compared against the medical physicist's shielding results. Percentage errors between the geometry-based approach and RadShield's approach in finding the magnitude and location of the maximum air-kerma rate was within 0.00124% and 14 mm. RadShield's barrier thickness calculations were found to be within 0.156 mm lead (Pb) and 0.150 mm lead (Pb) for the adjacent catheteriza-tion labs and R&F room examples, respectively. However, within the R&F room example, differences in locating the most sensitive calculation point on the floor plan for one of the barriers was not considered in the medical physicist's calculation and was revealed by the RadShield calculations. RadShield is shown to accurately find the maximum values of air-kerma rate and barrier thickness using NCRP Report 147 methodology. Visual inspection alone of the 2D X-ray exam distribution by a medical physicist may not

  11. Re-Shielding of Cobalt-60 Teletherapy Rooms for Tomotherapy and Conventional Linear Accelerators using Monte Carlo Simulations

    Science.gov (United States)

    Çeçen, Yiğit; Yazgan, Çağrı

    2017-09-01

    Purpose. Nearly all Cobalt-60 teletherapy machines were removed around the world during the last two decades. The remaining ones are being used for experimental purposes. However, the rooms of these teletherapy machines are valuable because of lack of space in radiotherapy clinics. In order to place a new technology treatment machine in one of these rooms, one should re-shield the room since it was designed only for 1.25 MeV gamma beams on average. Mostly, the vendor of the new machine constructs the new shielding of the room using their experience. However, every radiotherapy room has different surrounding work areas and it would be wise to shield the room considering these special conditions. Also, the shield design goal of the clinic may be much lower than the International Atomic Energy Agency (IAEA) or the local association accepts. The study shows re-shielding of a Cobalt-60 room, specific to the clinic, using Monte Carlo simulations. Materials & Methods: First, a 6 MV Tomotherapy machine, then a 10 MV conventional linear accelerator (LINAC) was placed inside the Cobalt-60 teletherapy room. The photon flux outside the room was simulated using Monte Carlo N-Particle (MCNP6.1) code before and after re-shielding. For the Tomotherapy simulation, flux distributions around the machine were obtained from the vendor and implemented as the source of the model. The LINAC model was more generic with the 10 MeV electron source, the tungsten target, first and secondary collimators. The aim of the model was to obtain the maximum (40x40 cm2) open field at the isocenter. Two different simulations were carried out for gantry angles 90o and 270o. The LINAC was placed in the room such that the primary walls were A' (Gantry 270o) and C' (Gantry 90o) (figure 1). The second part of the study was to model the re-shielding of the room for Tomotherapy and for the conventional LINAC, separately. The aim was to investigate the recommended shielding by the vendors. Left side of the room

  12. REPOSITORY RADIATION SHIELDING DESIGN GUIDE

    International Nuclear Information System (INIS)

    M. Haas; E.M. Fortsch

    1997-01-01

    The scope of this document includes radiation safety considerations used in the design of facilities for the Yucca Mountain Site Characterization Project (YMP). The purpose of the Repository Radiation Shielding Design Guide is to document the approach used in the radiological design of the Mined Geologic Disposal System (MGDS) surface and subsurface facilities for the protection of workers, the public, and the environment. This document is intended to ensure that a common methodology is used by all groups that may be involved with Radiological Design. This document will also assist in ensuring the long term survivability of the information basis used for radiological safety design and will assist in satisfying the documentation requirements of the licensing body, the Nuclear Regulatory Commission (NRC). This design guide provides referenceable information that is current and maintained under the YMP Quality Assurance (QA) Program. Furthermore, this approach is consistent with maintaining continuity in spite of a changing design environment. This approach also serves to ensure common inter-disciplinary interpretation and application of data

  13. REPOSITORY RADIATION SHIELDING DESIGN GUIDE

    Energy Technology Data Exchange (ETDEWEB)

    M. Haas; E.M. Fortsch

    1997-09-12

    The scope of this document includes radiation safety considerations used in the design of facilities for the Yucca Mountain Site Characterization Project (YMP). The purpose of the Repository Radiation Shielding Design Guide is to document the approach used in the radiological design of the Mined Geologic Disposal System (MGDS) surface and subsurface facilities for the protection of workers, the public, and the environment. This document is intended to ensure that a common methodology is used by all groups that may be involved with Radiological Design. This document will also assist in ensuring the long term survivability of the information basis used for radiological safety design and will assist in satisfying the documentation requirements of the licensing body, the Nuclear Regulatory Commission (NRC). This design guide provides referenceable information that is current and maintained under the YMP Quality Assurance (QA) Program. Furthermore, this approach is consistent with maintaining continuity in spite of a changing design environment. This approach also serves to ensure common inter-disciplinary interpretation and application of data.

  14. Thermal design of top shield for PFBR

    International Nuclear Information System (INIS)

    Gajapathy, R.; Jalaludeen, S.; Selvaraj, A.; Bhoje, S.B.

    1988-01-01

    India's Liquid Metal Cooled Fast Breeder Reactor programme started with the construction of loop type 13MW(e) Fast Breeder Test Reactor (FBTR) which attained criticality in October 1985. With the experience of FBTR, the design work on pool type 500 MW(e) Prototype Fast Breeder Reactor (PFBR) which will be a forerunner for future commercial fast breeder reactors, has been started. The Top Shield forms the cover for the main vessel which contains the primary circuit. Argon cover gas separates the Top Shield from the free level of hot sodium pool (803K). The Top Shield which is of box type construction consists of control plug, two rotatable plugs and roof slab, assembled together, which provide biological shielding, thermal shielding and leak tight containment at the top of the main vessel. Heat is transferred from the sodium pool to the Top Shield through argon cover gas and through components supported by it and dipped in the sodium pool. The Top Shield should be maintained at the desired operating temperature by incorporating a cooling system inside it. Insulation may be provided below the bottom plate to reduce the heat load to the cooling system, if required. The thermal design of Top Shield consists of estimation of heat transfer to the Top Shield, selection of operating temperature, assessment of insulation requirement, design of cooling system and evaluation of transient temperature changes

  15. Shielding design of ITER pressure suppression system

    International Nuclear Information System (INIS)

    Yamauchi, Michinori; Sato, Satoshi; Nishitani, Takeo; Kawasaki, Hiromitsu

    2006-01-01

    The duct shield from streaming D-T neutrons has been designed for the ITER pressure suppression system. Streaming calculations are performed with the DUCT-III code for the region from the inlet of the pressure relief line to the rupture disk. Next, the neutron permeation through the shield is studied by Monte Carlo calculations with the MCNP code. It is found that 0.15 m thick iron shield is enough to suppress the permeating component from the outside. In addition, it is suggested that the volume of the shield can be reduced by about 30% if the optimized iron shield structure having localized thickness across intense permeation paths is employed to shield the pressure suppression line. (T.I.)

  16. Thermal design of top shield

    International Nuclear Information System (INIS)

    Raghupathy, S.; Velusamy, K.; Parthasarathy, U.; Ghosh, D.; Selvaraj, P.; Chellapandi, P.; Chetal, S.C.

    2005-01-01

    Full text of publication follows: Prototype Fast Breeder Reactor (PFBR) is a 500 MWe, sodium cooled, pool type fast reactor. The top shield forms the top cover for the main vessel (MV) and includes roof slab (RS), large rotatable plug (LRP), small rotatable plug (SRP) and control Plug (CP). RS, LRP and SRP are box type structures consisting of top and bottom plates stiffened by radial stiffeners and vertical penetration shells. TS is exposed to argon cover gas provided above sodium pool on the bottom side and reactor containment building air at the top. Heat transfer takes place through the argon cover gas to the bottom plate of TS. Annular gaps are formed between the components supported on TS and the component penetrations through which cellular convection takes place. A single thermal shield provided below TS reduces the heat flux to the bottom plate to 1.15 kW/m 2 . The MV (SS 316 LN) is welded to RS (carbon steel A48 P2) through a dissimilar metal weld. A step in RS and an anti convection barrier (ACB) outside RS are provided to limit the temperature at the MV-RS junction. The MV is surrounded by safety vessel (SV) and reactor vault made of concrete. Thermal insulation is provided outside SV to limit the heat transfer to the reactor vault. The design requirements of TS are to maintain the operating temperature at 383-393 K, limit the temperature difference (ΔT) across the height of TS to 20 / 100 K under normal operation/loss of cooling, provide minimum annular gap size at the component penetrations, provide a nearly linear temperature gradient in the CP portion within the height of TS, maintain the temperature of top plate of CP > 383 K, limit the ΔT across the top plate of CP to 2 K, limit the temperature near the inflatable / backup seal to 393 K, limit the temperature at the MV-RS junction and the heat flux to the reactor vault. The total heat transferred to TS is estimated to be 210 kW. A dedicated closed loop cooling system with a total flow rate of 10

  17. Comparison between steel and lead shieldings for radiotherapy rooms regarding neutron doses to patients

    Energy Technology Data Exchange (ETDEWEB)

    Silva, M.G.; Rebello, W.F.; Andrade, E.R.; Medeiros, M.P.C.; Mendes, R.M.S.; Braga, K.L.; Gomes, R.G., E-mail: eng.cavaliere@gmail.com, E-mail: ggrprojetos@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Secao de Engenharia Nuclear; Silva, A.X., E-mail: ademir@con.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The NCRP Report No. 151, Structural Shielding Design and Evaluation for Megavoltage X- and Gamma-Ray Radiotherapy Facilities, considers, in shielding calculations for radiotherapy rooms, the use of lead and/or steel to be applied on bunker walls. The NCRP Report calculations were performed foreseeing a better protection of people outside the radiotherapy room. However, contribution of lead and steel to patient dose should be taken into account for radioprotection purposes. This work presents calculations performed by MCNPX code in analyzing the Ambient Dose Equivalent due to neutron, H *(10){sub n}, within a radiotherapy room, in the patients area, considering the use of additional shielding of 1 TVL of lead or 1 TVL of steel, positioned at the inner faces of walls and ceiling of a bunker. The head of the linear accelerator Varian 2100/2300 C/D was modeled working at 18MeV, with 5 x 5 cm{sup 2}, 10 x 10 cm{sup 2}, 20 x 20 cm{sup 2}, 30 x 30 cm{sup 2} and 40 x 40 cm{sup 2} openings for jaws and MLC and operating in eight gantry's angles. This study shows that the use of lead generates an average value of H *(10){sub n} at patients area, 8.02% higher than the expected when using steel. Further studies should be performed based on experimental data for comparison with those from MCNPX simulation. (author)

  18. Comparison between steel and lead shieldings for radiotherapy rooms regarding neutron doses to patients

    International Nuclear Information System (INIS)

    Silva, M.G.; Rebello, W.F.; Andrade, E.R.; Medeiros, M.P.C.; Mendes, R.M.S.; Braga, K.L.; Gomes, R.G.

    2015-01-01

    The NCRP Report No. 151, Structural Shielding Design and Evaluation for Megavoltage X- and Gamma-Ray Radiotherapy Facilities, considers, in shielding calculations for radiotherapy rooms, the use of lead and/or steel to be applied on bunker walls. The NCRP Report calculations were performed foreseeing a better protection of people outside the radiotherapy room. However, contribution of lead and steel to patient dose should be taken into account for radioprotection purposes. This work presents calculations performed by MCNPX code in analyzing the Ambient Dose Equivalent due to neutron, H *(10) n , within a radiotherapy room, in the patients area, considering the use of additional shielding of 1 TVL of lead or 1 TVL of steel, positioned at the inner faces of walls and ceiling of a bunker. The head of the linear accelerator Varian 2100/2300 C/D was modeled working at 18MeV, with 5 x 5 cm 2 , 10 x 10 cm 2 , 20 x 20 cm 2 , 30 x 30 cm 2 and 40 x 40 cm 2 openings for jaws and MLC and operating in eight gantry's angles. This study shows that the use of lead generates an average value of H *(10) n at patients area, 8.02% higher than the expected when using steel. Further studies should be performed based on experimental data for comparison with those from MCNPX simulation. (author)

  19. Evaluation of the room shielding thickness of Hi-Art tomotherapy system

    International Nuclear Information System (INIS)

    Liu Haikuan; Wu Jinhai; Gu Naigu; Gao Yiming; Wang Li; Huang Weiqin; Wang Fengxian

    2010-01-01

    In this paper, we calculate and evaluate the room shielding thickness of a Hi-Art tomotherapy system, which is a new type of radiotherapy facility. Due to the self-shielding of the accelerator,only scattered beam and beam leakage were considered in calculating the room shielding thickness. The radiation field of the tomotherapy system was used as the basic data to calculate the shielding thickness of every 15 degree solid angle. The maximum shielding thickness required of each shielding wall was at the position with the angle of 15 degree, and the calculated shielding thickness were 1023, 975, 917, 1460, 1147 and 1189 mm for the east wall,south wall,west wall, north wall, the roof and the floor,respectively. According to the calculation results, all shielding walls, ceiling and floor could meet the requirement of the radiation protection, but the north wall thickness of 1200 mm was a little thinner. (authors)

  20. MFTF-α + T shield design

    International Nuclear Information System (INIS)

    Gohar, Y.

    1985-01-01

    MFTF-α+T is a DT upgrade option of the Tandem Mirror Fusion Test Facility (MFTF-B) to study better plasma performance, and test tritium breeding blankets in an actual fusion reactor environment. The central cell insert, designated DT axicell, has a 2-MW/m 2 neutron wall loading at the first wall for blanket testing. This upgrade is completely shielded to protect the reactor components, the workers, and the general public from the radiation environment during operation and after shutdown. The shield design for this upgrade is the subject of this paper including the design criteria and the tradeoff studies to reduce the shield cost

  1. Shielding design for better plant availability

    International Nuclear Information System (INIS)

    Biro, G.G.

    1975-01-01

    Design methods are described for providing a shield system for nuclear power plants that will facilitate maintenance and inspection, increase overall plant availability, and ensure that man-rem exposures are as low as practicable

  2. Design of ITER shielding blanket

    International Nuclear Information System (INIS)

    Furuya, Kazuyuki; Sato, Satoshi; Hatano, Toshihisa; Tokami, Ikuhide; Kitamura, Kazunori; Miura, Hidenori; Ito, Yutaka; Kuroda, Toshimasa; Takatsu, Hideyuki

    1997-05-01

    A mechanical configuration of ITER integrated primary first wall/shield blanket module were developed focusing on the welded attachment of its support leg to the back plate. A 100 mm x 150 mm space between the legs of adjacent modules was incorporated for the working space of welding/cutting tools. A concept of coolant branch pipe connection to accommodate deformation due to the leg welding and differential displacement of the module and the manifold/back plate during operation was introduced. Two-dimensional FEM analyses showed that thermal stresses in Cu-alloy (first wall) and stainless steel (first wall coolant tube and shield block) satisfied the stress criteria following ASME code for ITER BPP operation. On the other hand, three-dimensional FEM analyses for overall in-vessel structures exhibited excessive primary stresses in the back plate and its support structure to the vacuum vessel under VDE disruption load and marginal stresses in the support leg of module No.4. Fabrication procedure of the integrated primary first wall/shield blanket module was developed based on single step solid HIP for the joining of Cu-alloy/Cu-alloy, Cu-alloy/stainless steel, and stainless steel/stainless steel. (author)

  3. Mechanical design of the TIBER breeding shield

    Energy Technology Data Exchange (ETDEWEB)

    Rathke, J.; Deutsch, L. (Grumman Corp., Bethpage, NY (USA). Space Systems Div.)

    1989-04-01

    TIBER features a segmented shield assembly that provides the nuclear shielding for the superconducting toroidal field coils. In addition to its primary function, the shield also provides tritium breeding through the use of water coolant that contains 16 wt% dissolved lithium nitrate. Because the TIBER reactor need not provide electrical power, the coolant is maintained at low pressure (0.2 MPa) and low temperature (75/sup 0/C). The shield is made in several segments to facilitate assembly and allow for replacement of high heat flux components (divertor blades). The segments are designated as inboard, outboard, upper, lower, and divertor modules. In total, there are 96 separate modules in the machine, consisting of six different types. The design features of the different modules vary primarily depending on the thickness of the shield in a given location. The very thick outboard shield has a breeding zone in the inboard portion of the module, with a shielding zone behind it. The breeding zone consists of a stainless steel casing filled with beryllium spheres. The shielding zone consists of the same casing filled with steel spheres. Both of these zones have lithiated water circulated throughout to provide cooling and breeding. In zones with minimal thickness, tungsten alloys are used to achieve the required shielding. These alloys are incoprorated in subassemblies utilizing stainless steel casings surrounding blocks of tungsten heavy metal alloy. These are infiltrated with lead on final assembly to form a thermally continuous panel. Several of these panels are then assembled into an outer stainless steel case to form an inboard module. These modules also use the lithiated coolant. The details of the design are presented and discussed. (orig.).

  4. Shielding design to obtain compact marine reactor

    International Nuclear Information System (INIS)

    Yamaji, Akio; Sako, Kiyoshi

    1994-01-01

    The marine reactors equipped in previously constructed nuclear ships are in need of the secondary shield which is installed outside the containment vessel. Most of the weight and volume of the reactor plants are occupied by this secondary shield. An advanced marine reactor called MRX (Marine Reactor X) has been designed to obtain a more compact and lightweight marine reactor with enhanced safety. The MRX is a new type of marine reactor which is an integral PWR (The steam generator is installed in the pressure vessel.) with adopting a water-filled containment vessel and a new shielding design method of no installation of the secondary shield. As a result, MRX is considerably lighter in weight and more compact in size as compared with the reactors equipped in previously constructed nuclear ships. For instance, the plant weight and volume of the containment vessel of MRX are about 50% and 70% of those of the Nuclear Ship MUTSU, in spite of the power of MRX is 2.8 times as large as the MUTSU's reactor. The shielding design calculation was made using the ANISN, DOT3.5, QAD-CGGP2 and ORIGEN codes. The computational accuracy was confirmed by experimental analyses. (author)

  5. Shielding design for positron emission tomography facility

    International Nuclear Information System (INIS)

    Abdallah, I.I.

    2007-01-01

    With the recent advent of readily available tracer isotopes, there has been marked increase in the number of hospital-based and free-standing positron emission tomography (PET) clinics. PET facilities employ relatively large activities of high-energy photon emitting isotopes, which can be dangerous to the health of humans and animals. This coupled with the current dose limits for radiation worker and members of the public can result in shielding requirements. This research contributes to the calculation of the appropriate shielding to keep the level of radiation within an acceptable recommended limit. Two different methods were used including measurements made at selected points of an operating PET facility and computer simulations by using Monte Carlo Transport Code. The measurements mainly concerned the radiation exposure at different points around facility using the survey meter detectors and Thermoluminescent Dosimeters (TLD). Then the set of manual calculation procedures were used to estimate the shielding requirements for a newly built PEF facility. The results from the measurement and the computer simulation were compared to the results obtained from the set manual calculation procedure. In general, the estimated weekly dose at the points of interest is lower than the regulatory limits for the little company of Mary Hospital. Furthermore, the density and the HVL for normal strength concrete and clay bricks are almost similar. In conclusion, PET facilities present somewhat different design requirements and are more likely to require additional radiation shielding. Therefore, existing shields at the little Company of Mary Hospital are in general found to be adequate and satisfactory and additional shielding was found necessary at the new PET facility in the department of Nuclear Medicine of the Dr. George Mukhari Hospital. By use of appropriate design, by implying specific shielding requirements and by maintaining good operating practices, radiation doses to

  6. Development of shielding design analysis system

    International Nuclear Information System (INIS)

    Tada, Keiko; Shiraki, Takako

    2001-03-01

    The aim of this work is to develop insufficient auxiliary routines which manage input and output data and interface the main codes and to establish a shielding design analysis system on work stations (SUN, DEC). In shielding design analyses, one- and two- dimensional (1-D and 2-D) transport Sn codes are used mainly with some auxiliary codes which generate input data of Sn calculation and edit Sn calculation outputs. The main transport calculation codes can be obtained from the Code Center of RIST (Research Organization for Information Science and Technology). In this work, peripheral codes are developed to generate cross sections, produce Sn quadrature sets, edit calculation outputs or draw contour figures. In shielding calculations around a reactor, the boot-strapping technique is often employed to treat a large area extending from the core to the biological shield to improve the calculation accuracy. When a three-dimensional (3-D) calculation for a complex geometry with shielding defects, 2-D and 3-D coupling calculation is employed frequently. To use this coupling method conversion cods are prepared which read flux file from DORT and prepare an external boundary source file for the 2-D or the 3-D calculation codes. For further conveniences well used data such as the Sn quadrature sets, the dose rate conversion factors, the reaction cross section sets are stored as a data base and code manuals including sample inputs of typical problems are prepared which are comprehensible to beginners. (author)

  7. Structural considerations for the practical development of primary shielding of X-ray rooms of megavoltage

    International Nuclear Information System (INIS)

    Lava, Deise D.; Borges, Diogo da S.; Affonso, Renato R.W.; Moreira, Maria de L.; Guimaraes, Antonio C.F.

    2014-01-01

    Due to the necessity of the use of accelerators with voltages above 10 MV in medical facilities, becomes necessary to evaluate the efficiency of the thickness of shielding materials used in rooms that contain these devices. This work presents the development of an algorithm able to provide data in a practical way, regarding the thickness of materials that can be used for an effective shielding against primary beams from these equipment. The use of the computer language C ++ allowed developing a practical tool for determining the thickness of materials required to protect the public and Individuals Occupationally Exposed (IOEs) against major powers beams. Furthermore, it was considered by calculations Intensity Modulated Radiotherapy Technique (IMRT). The construction of this tool was based to ensure the dose limits established in the CNEN-NN-3.01. The dose limiting is done through the use of loops able to validate the efficiency of thickness determined by the algorithm itself, and ensure if the radiation dose exceeds the limits set by the standard, it will be the inclusion of sufficient Half-Reducer Layers in so that the dose is within the parameters established by the Brazilian National Nuclear Energy Commission (CNEN). The code validation is performed by comparing results obtained in the examples p recalculated in the NCRP Report-151 (Structural Shielding Design and Evaluation for megavoltage X and Gamma-Ray Radiotherapy Facilities) with the results generated by the code. The results are satisfactory and consistent with that report

  8. Ergonomics and control room design

    International Nuclear Information System (INIS)

    Williams, J.C.; Story, D.T.

    1987-01-01

    The application of ergonomic principles to the design process and some aspects of the Sizewell B control room is discussed. Also outlined is the management process which ensures that these principles are applied systematically throughout the design development activity and highlights the functional requirements which must also be met in the creation of a total man-machine system package which meets all the technical design criteria. The ergonomics requirements are part of this process and extend into all aspects of design ranging from such matters as workplace organization to environmental factors, social engineering, communications and aesthetics. (author)

  9. Design and analysis of ITER shield blanket

    Energy Technology Data Exchange (ETDEWEB)

    Ohmori, Junji; Hatano, Toshihisa; Ezato, Kouichiro [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment] [and others

    1998-12-01

    This report includes electromagnetic analyses for ITER shielding blanket modules, fabrication methods for the blanket modules and the back plate, the design and the fabrication methods for port limiter have been investigated. Studies on the runaway electron impact for Be armor have been also performed. (J.P.N.)

  10. Evaluation of shielding capability of controlled area for CT examination room

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Asada, Yasuki; Nakai, Takayo; Takeuchi, Kichito; Kinoshita, Kazuo; Watanabe, Nobuyuki; Koga, Sukehiko

    2002-01-01

    With the revision of the law in April, 2001, the effective dose at the boundary of the controlled area was set at 1.3 mSv/3M. Whether the shielding capability of the CT room satisfied the provisions of the law or not was confirmed by actual measurements. Both thermo luminescence dosemeter (TLD) and electronic dosemeter were used to measure the radiation doses. The shielding capability of the gantry was studied both inside and outside the room for a week as a basic experiment. On the basis of the data thus obtained doses accumulated in 3 months were estimated. According to the results of 3 month-measurement, the doses outside the wall of the CT room were about 200μ Sv. This numerical value was comparable to the background level of the evaluation point. The results above assured that the shielding capability of the CT room satisfied the provisions of the law well. (author)

  11. Shielding of Medical Facilities. Shielding Design Considerations for PET-CT Facilities

    International Nuclear Information System (INIS)

    Cruzate, J.A.; Discacciatti, A.P.

    2011-01-01

    The radiological evaluation of a Positron Emission Tomography (PET) facility consists of the assessment of the annual effective dose both to workers occupationally exposed, and to members of the public. This assessment takes into account the radionuclides involved, the facility features, the working procedures, the expected number of patients per year, and so on. The evaluation embraces the distributions of rooms, the thickness and physical material of walls, floors and ceilings. This work detail the methodology used for making the assessment of a PET facility design taking into account only radioprotection aspects. The assessment results must be compared to the design requirements established by national regulations in order to determine whether or not, the facility complies with those requirements, both for workers and for members of the public. The analysis presented is useful for both, facility designers and regulators. In addition, some guidelines for improving the shielding design and working procedures are presented in order to help facility designer's job. (authors)

  12. Production of a datolite-based heavy concrete for shielding nuclear reactors and megavoltage radiotherapy rooms

    International Nuclear Information System (INIS)

    Mortazavi, S. M. J.; Mosleh-Shirazi, M.A.; Baradaran-Ghahfarokhi, M.; Siavashpour, Z.; Farshadi, A.; Ghafoori, M.; Shahvar, A.

    2010-01-01

    Biological shielding of nuclear reactors has always been a great concern and decreasing the complexity and expense of these installations is of great interest. In this study, we used datolite and galena minerals for production of a high performance heavy concrete. Materials and Methods: Datolite and galena minerals which can be found in many parts of Iran were used in the concrete mix design. To measure the gamma radiation attenuation of the Datolite and galena concrete samples, they were exposed to both narrow and wide beams of gamma rays emitted from a cobalt-60 radiotherapy unit. An Am-Be neutron source was used for assessing the shielding properties of the samples against neutrons. To test the compression strengths, both types of concrete mixes (Datolite and galena and ordinary concrete) were investigated. Results: The concrete samples had a density of 4420-4650 kg/m 3 compared to that of ordinary concrete (2300-2500 kg/m 3 ) or barite high density concrete (up to 3500 kg/m 3 ). The measured half value layer thickness of the Datolite and galena concrete samples for cobalt-60 gamma rays was much less than that of ordinary concrete (2.56 cm compared to 6.0 cm). Furthermore, the galena concrete samples had a significantly higher compressive strength as well as 20% more neutron absorption. Conclusion: The Datolite and galena concrete samples showed good shielding/engineering properties in comparison with other reported samples made, using high-density materials other than depleted uranium. It is also more economic than the high-density concretes. Datolite and galena concrete may be a suitable option for shielding nuclear reactors and megavoltage radiotherapy rooms.

  13. Helical tomotherapy shielding calculation for an existing LINAC treatment room: sample calculation and cautions

    International Nuclear Information System (INIS)

    Wu Chuan; Guo Fanqing; Purdy, James A

    2006-01-01

    This paper reports a step-by-step shielding calculation recipe for a helical tomotherapy unit (TomoTherapy Inc., Madison, WI, USA), recently installed in an existing Varian 600C treatment room. Both primary and secondary radiations (leakage and scatter) are explicitly considered. A typical patient load is assumed. Use factor is calculated based on an analytical formula derived from the tomotherapy rotational beam delivery geometry. Leakage and scatter are included in the calculation based on corresponding measurement data as documented by TomoTherapy Inc. Our calculation result shows that, except for a small area by the therapists' console, most of the existing Varian 600C shielding is sufficient for the new tomotherapy unit. This work cautions other institutions facing the similar situation, where an HT unit is considered for an existing LINAC treatment room, more secondary shielding might be considered at some locations, due to the significantly increased secondary shielding requirement by HT. (note)

  14. An Optimisation Approach for Room Acoustics Design

    DEFF Research Database (Denmark)

    Holm-Jørgensen, Kristian; Kirkegaard, Poul Henning; Andersen, Lars

    2005-01-01

    This paper discuss on a conceptual level the value of optimisation techniques in architectural acoustics room design from a practical point of view. It is chosen to optimise one objective room acoustics design criterium estimated from the sound field inside the room. The sound field is modeled...... using the boundary element method where absorption is incorporated. An example is given where the geometry of a room is defined by four design modes. The room geometry is optimised to get a uniform sound pressure....

  15. Ford motor company NDE facility shielding design

    International Nuclear Information System (INIS)

    Metzger, R. L.; Van Riper, K. A.; Jones, M. H.

    2005-01-01

    Ford Motor Company proposed the construction of a large non-destructive evaluation laboratory for radiography of automotive power train components. The authors were commissioned to design the shielding and to survey the completed facility for compliance with radiation doses for occupationally and non-occupationally exposed personnel. The two X-ray sources are Varian Linatron 3000 accelerators operating at 9-11 MV. One performs computed tomography of automotive transmissions, while the other does real-time radiography of operating engines and transmissions. The shield thickness for the primary barrier and all secondary barriers were determined by point-kernel techniques. Point-kernel techniques did not work well for skyshine calculations and locations where multiple sources (e.g. tube head leakage and various scatter fields) impacted doses. Shielding for these areas was determined using transport calculations. A number of MCNP [Briesmeister, J. F. MCNPCA general Monte Carlo N-particle transport code version 4B. Los Alamos National Laboratory Manual (1997)] calculations focused on skyshine estimates and the office areas. Measurements on the operational facility confirmed the shielding calculations. (authors)

  16. Ford Motor Company NDE facility shielding design.

    Science.gov (United States)

    Metzger, Robert L; Van Riper, Kenneth A; Jones, Martin H

    2005-01-01

    Ford Motor Company proposed the construction of a large non-destructive evaluation laboratory for radiography of automotive power train components. The authors were commissioned to design the shielding and to survey the completed facility for compliance with radiation doses for occupationally and non-occupationally exposed personnel. The two X-ray sources are Varian Linatron 3000 accelerators operating at 9-11 MV. One performs computed tomography of automotive transmissions, while the other does real-time radiography of operating engines and transmissions. The shield thickness for the primary barrier and all secondary barriers were determined by point-kernel techniques. Point-kernel techniques did not work well for skyshine calculations and locations where multiple sources (e.g. tube head leakage and various scatter fields) impacted doses. Shielding for these areas was determined using transport calculations. A number of MCNP [Briesmeister, J. F. MCNPCA general Monte Carlo N-particle transport code version 4B. Los Alamos National Laboratory Manual (1997)] calculations focused on skyshine estimates and the office areas. Measurements on the operational facility confirmed the shielding calculations.

  17. Summary of Prometheus Radiation Shielding Nuclear Design Analyses , for information

    International Nuclear Information System (INIS)

    J. Stephens

    2006-01-01

    This report transmits a summary of radiation shielding nuclear design studies performed to support the Prometheus project. Together, the enclosures and references associated with this document describe NRPCT (KAPL and Bettis) shielding nuclear design analyses done for the project

  18. Monte Carlo methods for shield design calculations

    International Nuclear Information System (INIS)

    Grimstone, M.J.

    1974-01-01

    A suite of Monte Carlo codes is being developed for use on a routine basis in commercial reactor shield design. The methods adopted for this purpose include the modular construction of codes, simplified geometries, automatic variance reduction techniques, continuous energy treatment of cross section data, and albedo methods for streaming. Descriptions are given of the implementation of these methods and of their use in practical calculations. 26 references. (U.S.)

  19. Calculation and design for SSRF's bulk shield

    Energy Technology Data Exchange (ETDEWEB)

    Fang, K.M. [Shanghai Institute of Applied Physics, Chinese Academy of Science (China)]. E-mail: fangkm@sinap.ac.cn; Xu, X.J. [Shanghai Institute of Applied Physics, Chinese Academy of Science (China); Cai, J.H. [Shanghai Institute of Applied Physics, Chinese Academy of Science (China)

    2006-12-15

    Shielding design objectives for the SSRF are chosen, assumptions for beam loss rates are given, the methods used on the APS by Moe are summarized and introduced to make calculation and design on bulk shield, the factor of skyshine is also considered, design thicknesses for SSRF's bulk shield are presented.

  20. Room design in dental radiology

    International Nuclear Information System (INIS)

    Achalli, Sonika

    2013-01-01

    Radiography and radiographic examination of the patient form most valuable diagnostic tool in providing comprehensive dental care. The safe and effective use of the X-ray equipment is important for the protection of the patient, other members of the public and all members of the dental team. For patients, the risk that is associated with exposure to X-rays must always be weighed against the clinical benefit of an accurate diagnosis. The risks associated with the exposure to the X-rays during the radiographic examination of the patient must be minimised by meticulously adhering to good practice and thus carefully managing the use of dental radiological procedures. The dentist or the personnel who is the license holder for the X-ray equipment is ultimately responsible for the radiation safety at the workplace. One important method in limiting the possible risk of radiation exposure at workplace is the correct design of an X-ray room. This paper is aimed at discussing the guidelines and recommendations on X-ray room designs in dental radiology in order to facilitate radiation control and safe working conditions for radiation workers as well as the public. (author)

  1. A history of radiation shielding of x-ray therapy rooms

    International Nuclear Information System (INIS)

    McGinley, P.H.; Miner, M.S.

    1996-01-01

    In this report the history of shielding for radiation treatment rooms is traced from the time of the discovery of x rays to the present. During the early part of the twentieth century the hazards from ionizing radiation were recognized and the use of lead and other materials became common place for shielding against x rays. Techniques for the calculation of the shield thickness needed for x ray protection were developed in the 1920's, and shielding materials were characterized in terms of the half value layer or simple exponential factors. At the same time, better knowledge of the interaction between radiation and matter was acquired. With the development of high energy medical accelerators after 1940, new and more complex shielding problems had to be addressed. Recently, shielding requirements have become more stringent as standards for exposure of personnel and the general public have been reduced. The art of shielding of radiation treatment facilities is still being developed, and the need for a revision of the reports on shielding of medical accelerators from the National Council on Radiation Protection and Measurements is emphasized in this article. (author). 61 Refs., 3 Tabs

  2. Shielding modification design of the N.S. Mutsu

    International Nuclear Information System (INIS)

    Yamaji, A.; Miyakoshi, J.; Kageyama, T.; Futamura, Y.

    1983-01-01

    Shielding modification design of the N.S. Mutsu was performed for reducing the radiation doses outside the primary and the secondary shields by providing shields for neutrons streaming through the air gap between the pressure vessel and the primary shield. This was accomplished by replacing parts of the shields and adding new shields in the upper and lower sections of both primary and secondary shields, and also replacing the thermal insulator in the gap. The shielding design calculations were made using one- and two-dimensional discrete ordinates codes and also a point kernel code. Special attention was paid to the calculations of, (1) the neutrons streaming through the gap between the pressure vessel and the primary shield, (2) the radiations transmitted through the radial shield of the core in the primary shield, (3) the radiations transmitted through the upper and lower sections of the secondary shield, and (4) the dose rate equivalent in the accommodation area. Their calculational accuracies were estimated by analyzing various experiments. To support the modification, a variety of experiments and tests were carried out, which were material tests, cooling test of the primary shield, mechanical strength test of the double bottom, trial fabrication tests of new shields, performance degradation test of heavy concrete and duct streaming experiment in the secondary shield. (author)

  3. Evaluation of the shielding of a room for radiodiagnostic; Evaluacion del blindaje de una sala para radiodiagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Padilla R, Z. P. [Servicios de Salud de Zacatecas, Hospital de Especialidades en Salud Mental, Prolongacion 5 de mayo 1702-Sur, Parque Industrial, 98500 Calera de Victor Rosales, Zacatecas (Mexico); Acuna D, E.; Escareno J, E.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2011-10-15

    The X-ray discovery by Roentgen in 1895 and its application in diagnosis was a breakthrough in medicine. Worldwide, X-ray technique is one of the most widely used procedures in medical diagnosis. At the Mental Health Hospital of Calera Zacatecas a room has been designed as radiology room, however there is not a record of shielding characteristics. In order to determine the features of X-ray equipment that the room can host, in this work a series of calculations were carried out. Calculations were based upon the NCRP 151 recommendations and fulfilling the requirements given in the Mexican standard NOM-229-SSA1-2002. From the actual room conditions this can host a X-ray equipment without fluoroscopy, with a workload of 80 ma-min/week, with 125 k Vp as maximum operating voltage. From the actual conditions a set of recommendations, for better protection of radiation workers and public are also given. (Author)

  4. Shielding design at Fermilab: Calculations and measurements

    International Nuclear Information System (INIS)

    Cossairt, J.D.

    1986-11-01

    The development of the Fermilab accelerator complex during the past two decades from its concept as the ''200 BeV accelerator'' to that of the present tevatron, designed to operate at energies as high as 1 TeV, has required a coincidental refinement and development in methods of shielding design. In this paper I describe these methods as used by the radiation protection staff of Fermilab. This description will review experimental measurements which substantiate these techniques in realistic situations. Along the way, observations will be stated which likely are applicable to other protron accelerators in the multi-hundred GeV energy region, including larger ones yet to be constructed

  5. Guidelines for control room design reviews

    International Nuclear Information System (INIS)

    1981-09-01

    The control room design review is part of a broad program being undertaken by the nuclear industry and the government to ensure consideration of human factors in nuclear power plant design and operation. The purpose of the control room design review described by these guidelines is to (1) review and evaluate the control room workspace, instrumentation, controls, and other equipment from a human factors engineering point of view that takes into account both system demands and operator capabilities; and (2) to identify, assess, and implement control room design modifications that correct inadequate or unsuitable items. The scope of the control room design review described by these guidelines covers the human engineering review of completed control rooms; i.e., operational control rooms or those at that stage of the licensing process where control room design and equipment selection are committed. These guidelines should also be of use during the design process for new control rooms. However, additional analyses to optimize the allocation of functions to man and machine, and further examination of advanced control system technology, are recommended for new control rooms. Guidelines and references for comprehensive system analyses designed to incorporate human factors considerations into the design and development of new control rooms are presented in Appendix B. Where possible, a generic approach to the control room design review process is encouraged; for example, when control room designs are replicated wholly or in part in two or more units. Even when designs are not replicated exactly, generic reviews which can be modified to account for specific differences in particular control rooms should be considered. Industry organizations and owners groups are encouraged to coordinate joint efforts and share data to develop generic approaches to the design review process. The control room design review should accomplish the following specific objectives. To determine

  6. Multi-objective optimization design method of radiation shielding

    International Nuclear Information System (INIS)

    Yang Shouhai; Wang Weijin; Lu Daogang; Chen Yixue

    2012-01-01

    Due to the shielding design goals of diversification and uncertain process of many factors, it is necessary to develop an optimization design method of intelligent shielding by which the shielding scheme selection will be achieved automatically and the uncertainties of human impact will be reduced. For economical feasibility to achieve a radiation shielding design for automation, the multi-objective genetic algorithm optimization of screening code which combines the genetic algorithm and discrete-ordinate method was developed to minimize the costs, size, weight, and so on. This work has some practical significance for gaining the optimization design of shielding. (authors)

  7. Method for calculating required shielding in medical x-ray rooms

    International Nuclear Information System (INIS)

    Karppinen, J.

    1997-10-01

    The new annual radiation dose limits - 20 mSv (previously 50 mSv) for radiation workers and 1 mSv (previously 5 mSv) for other persons - implies that the adequacy of existing radiation shielding must be re-evaluated. In principle, one could assume that the thicknesses of old radiation shields should be increased by about one or two half-value layers in order to comply with the new dose limits. However, the assumptions made in the earlier shielding calculations are highly conservative; the required shielding was often determined by applying the maximum high-voltage of the x-ray tube for the whole workload. A more realistic calculation shows that increased shielding is typically not necessary if more practical x-ray tube voltages are used in the evaluation. We have developed a PC-based calculation method for calculating the x-ray shielding which is more realistic than the highly conservative method formerly used. The method may be used to evaluate an existing shield for compliance with new regulations. As examples of these calculations, typical x-ray rooms are considered. The lead and concrete thickness requirements as a function of x-ray tube voltage and workload are also given in tables. (author)

  8. The use of steel and lead shieldings in radiotherapy rooms and its comparison with respect to neutrons doses at patients

    International Nuclear Information System (INIS)

    Silva, M.G.; Rebello, W.F.; Andrade, E.R.; Medeiros, M.P.C.; Mendes, R.M.S.; Braga, K.L.; Gomes, R.G.; Santos, R.F.G.

    2015-01-01

    The NCRP Report No. 151, Structural Shielding Design and Evaluation for Megavoltage X- and Gamma-Ray Radiotherapy Facilities, considers, in shielding calculations for radiotherapy rooms, the use of lead and/or steel to be applied on bunker walls. The NCRP Report calculations were performed foreseeing a better protection of people outside the radiotherapy room. However, contribution of lead and steel to patient dose should be taken into account for radioprotection purposes. This work presents calculations performed by MCNPX code in analyzing the Ambient Dose Equivalent due to neutron, H*(10) n , within a radiotherapy room, in the patients area, considering the use of additional shielding of 1 TVL of lead or 1 TVL of steel, positioned at the inner faces of walls and ceiling of a bunker. The head of the linear accelerator Varian 2100/2300 C/D was modeled working at 18MeV, with 5x5cm 2 , 10x10cm 2 , 20x20cm 2 , 30x30cm 2 and 40x40cm 2 openings for jaws and MLC and operating in eight gantry's angles. This study shows that the use of lead generates an average value of H*(10) n at patients area, 8.02% higher than the expected when using steel. Further studies should be performed based on experimental data for comparison with those from MCNPX simulation.

  9. Shield design development of nuclear propulsion merchant ship

    International Nuclear Information System (INIS)

    Tanaka, Yoshihisa

    1975-01-01

    Shielding design both in Japan and abroad for nuclear propulsion merchant ships is explained, with emphasis on the various technological problems having occurred in the shield design for one-body type and separate type LWRs as conceptual design. The following matters are described: the peculiarities of the design as compared with the case of land-based nuclear reactors, problems in the design standards of shielding, the present status and development of the design methods, and the instances of the design; thereby, the trends of shielding design are disclosed. The following matters are pointed out: Importance of the optimum design, of shielding, significance of radiation streaming through large voids, activation of the secondary water in built-in type steam generators, and the need of the guides for shield design. (Mori, K.)

  10. Design of a treatment room for an 18 MV Linac

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez A, L.; Contreras S, H.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Perez L, L. H., E-mail: dameluis@hotmail.co [Instituto Zacatecano del Tumor, Apdo. Postal 294, 98000 Zacatecas (Mexico)

    2010-10-15

    In this work it has been calculated the treatment room for an 18 MV Linac. The walls thickness, the door and the maze were designed according to the NCRP Report 151 recommendations. The results of this work are contrasted with the Monte Carlo calculations performed with the MCNP5 code where dose equivalent due to neutrons and neutron spectra are estimated at different points inside and outside of the radiotherapy room, verify the shielding thickness obtained are enough to reduce the dose level allowed by the Mexican regulation. (Author)

  11. Applications to shielding design and others of monte carlo method

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Daiichiro [Mitsui Engineering and Shipbuiding Co., Ltd., Tokyo (Japan)

    2001-01-01

    One-dimensional or two-dimensional Sn computer code (ANISN, DOT3.5, etc.) and a point attenuation kernel integral code (QAD, etc.) have been used widely for shielding design. Application examples of monte carlo method which could follow precisely the three-dimensional configuration of shielding structure are shown as follow: (1) CASTER cask has a complex structure which consists of a large number of fuel baskets (stainless steel), neutron moderators (polyethylene rods), the body (cast iron), and cooling fin. The R-{theta} model of Sn code DOT3.5 cannot follow closely the complex form of polyethylene rods and fuel baskets. A monte carlo code MORSE is used to ascertain the calculation results of DOT3.5. The discrepancy between the calculation results of DOT3.5 and MORSE was in 10% for dose rate at distance of 1 m from the cask surface. (2) The dose rates of an iron cell at 10 cm above the floor are calculated by the code QAD and the MORSE. The reflected components of gamma ray caused by the auxiliary floor shield (lead) are analyzed by the MORSE. (3) A monte carlo code MCNP4A is used for skyshine evaluation of spent fuel carrier ship 'ROKUEIMARU'. The direct and skyshine components of gamma ray and neutron flux are estimated at each center of engine room and wheel house. The skyshine dose rate of neutron flux is 5-15 times larger than the gamma ray. (M. Suetake)

  12. Comparative study between NCRP-49 and NCRP-147 methodologies for shielding calculus to fluoroscopy rooms

    International Nuclear Information System (INIS)

    Ferreira, Christiano Eduardo Martins

    2011-01-01

    The walls of a fluoroscopy room must be shielded to prevent unnecessary exposures to technicians and public individuals. Thus this dissertation aims to describe the methodologies contained in two documents which are references for the calculation of shielding those rooms. They are the National Council on Radiation Protection and Measurements Report No. 49 (NCRP Report No. 49) and No. 147 (NCRP Report No. 147), the latter being more recent publication. And based on such description was made a comparative study between the two methodologies, using for this, as a benchmark, spreadsheets computer program developed by Wolfram Mathematica 6. With that we could reach the final thickness of the barriers to a Standard Plan for a fluoroscopy room (provided by Siemens) and noted that the NCRP-49 presents a methodology with results more conservative. (author)

  13. Conceptual design of ITER shielding blanket

    International Nuclear Information System (INIS)

    Sato, Satoshi; Takatsu, Hideyuki; Kurasawa, Toshimasa

    1995-03-01

    The present report summarizes the design activities of the ITER first wall and shielding blanket conducted by the JA Home Team during this year (1994) in close contact with the JCT, and reported during the four Technical Meetings held at Garching ITER Co-center. These activities are based on the Task Agreement between the JCT and the JA Home Team. In the present report, a layered configuration composed of separate first walls, modular-type blanket modules and separate back plates has been proposed to realize reliable assembly and maintenance schemes as well as to realize reliable component designs under high surface heat loads, high neutron wall loading and electromagnetic loads during disruptions. Outline of the structural design, consideration on fabricability and maintainability, and the results of thermal, mechanical and electromagnetic analyses are described. (author)

  14. Magnetic shielding structure optimization design for wireless power transmission coil

    Science.gov (United States)

    Dai, Zhongyu; Wang, Junhua; Long, Mengjiao; Huang, Hong; Sun, Mingui

    2017-09-01

    In order to improve the performance of the wireless power transmission (WPT) system, a novel design scheme with magnetic shielding structure on the WPT coil is presented in this paper. This new type of shielding structure has great advantages on magnetic flux leakage reduction and magnetic field concentration. On the basis of theoretical calculation of coil magnetic flux linkage and characteristic analysis as well as practical application feasibility consideration, a complete magnetic shielding structure was designed and the whole design procedure was represented in detail. The simulation results show that the coil with the designed shielding structure has the maximum energy transmission efficiency. Compared with the traditional shielding structure, the weight of the new design is significantly decreased by about 41%. Finally, according to the designed shielding structure, the corresponding experiment platform is built to verify the correctness and superiority of the proposed scheme.

  15. The Spallation Neutron Source (SNS) conceptual design shielding analysis

    International Nuclear Information System (INIS)

    Johnson, J.O.; Odano, N.; Lillie, R.A.

    1998-03-01

    The shielding design is important for the construction of an intense high-energy accelerator facility like the proposed Spallation Neutron Source (SNS) due to its impact on conventional facility design, maintenance operations, and since the cost for the radiation shielding shares a considerable part of the total facility costs. A calculational strategy utilizing coupled high energy Monte Carlo calculations and multi-dimensional discrete ordinates calculations, along with semi-empirical calculations, was implemented to perform the conceptual design shielding assessment of the proposed SNS. Biological shields have been designed and assessed for the proton beam transport system and associated beam dumps, the target station, and the target service cell and general remote maintenance cell. Shielding requirements have been assessed with respect to weight, space, and dose-rate constraints for operating, shutdown, and accident conditions. A discussion of the proposed facility design, conceptual design shielding requirements calculational strategy, source terms, preliminary results and conclusions, and recommendations for additional analyses are presented

  16. HAMMLAB 1999 experimental control room: design - design rationale - experiences

    International Nuclear Information System (INIS)

    Foerdestroemmen, N. T.; Meyer, B. D.; Saarni, R.

    1999-01-01

    A presentation of HAMMLAB 1999 experimental control room, and the accumulated experiences gathered in the areas of design and design rationale as well as user experiences. It is concluded that HAMMLAB 1999 experimental control room is a realistic, compact and efficient control room well suited as an Advanced NPP Control Room (ml)

  17. Quality control, mean glandular dose estimate and room shielding calculation in mammography

    International Nuclear Information System (INIS)

    Rakotomalala, H.M.

    2014-01-01

    This study focuses in the importance of Radiation Protection in mammography. A good control of the radiological risk depends on the dose optimization, room shielding calculation and the quality of equipment. The work was carried out in the three private medical centers called A, B, and C. Dosimetry estimates were made on the equipment of the three centers. Values has been compared with the Diagnostic Reference Levels established by the International Atomic Energy Agency (IAEA). Conformity control of the radiological devices has also been done with the Mammographic Quality Control Kit of the INSTN-Madagascar. Verifications of shields of the room containing the mammography equipment were done by theoretical calculations using the method provided by NCRP 147. [fr

  18. Shield requirement estimation for pin storage room in fuel fabrication plant

    International Nuclear Information System (INIS)

    Shanthi, M.M.; Keshavamurthy, R.S.; Sivashankaran, G.

    2012-01-01

    Fast Reactor Fuel Cycle Facility (FRFCF) is an upcoming project in Kalpakkam. It has the facility to recycle the fuel from PFBR. It is an integrated facility, consists of fuel reprocessing plant, fuel fabrication plant (FFP), core subassembly plant, Reprocessed Uranium plant (RUP) and waste management plant. The spent fuel from PFBR would be reprocessed in fuel reprocessing plant. The reprocessed fuel material would be sent to fuel fabrication plant. The main activity of fuel fabrication plant is the production of MOX fuel pins. The fuel fabrication plant has a fuel pin storage room. The shield requirement for the pin storage room has been estimated by Monte Carlo method. (author)

  19. Improvement of open-type magnetically shielded room composed of magnetic square cylinders by controlling flux path

    International Nuclear Information System (INIS)

    Hirosato, S.; Yamazaki, K.; Tsuruta, T.; Haraguchi, Y.; Kosaka, M.; Gao, Y.; Muramatsu, K.; Kobayashi, K.

    2011-01-01

    We have developed an open-type magnetically shielded room composed of magnetic square cylinders that has been used for an actual MRI in a hospital. To improve shielding performance, we propose here a method to control the path of the magnetic flux in the wall composed of the magnetic square cylinders by changing the magnetic permeability in each direction of the square cylinders spatially. First, we discuss a method to control the magnetic permeability in each direction of the square cylinders independently by inserting slits without changing the outside dimensions of the square cylinders, by using 3-D magnetic field analysis. Then, the effectiveness of the design of controlling the flux pass was shown by magnetic field analysis and experiments. (author)

  20. Control room and ergonomic design

    International Nuclear Information System (INIS)

    Hinz, W.

    1984-01-01

    The important basis for the configuration of the control room of a nuclear power station is the concept for controlling a fault and that for controlling normal operation. The tasks resulting from this for the control room personnel are decided by the control room concept. In this configuration process (from the division of process control tasks between the system components operators and control technology to the configuration of individual means of operation) the characteristics and capabilities of the personnel, which are subject to special requirements as regards their qualifications, are observed. New concepts which are only now technically feasible are therefore being developed for information processing and display, in order to give the personnel a better oversight of the state and trends of the plant. (orig./DG) [de

  1. Practical high-density shielding materials for medical linear accelerator rooms

    International Nuclear Information System (INIS)

    Barish, R.J.

    1990-01-01

    High-energy linear accelerators are replacing lower energy units in radiation therapy centers. Radiation protection requirements necessitate expensive reconstruction of existing treatment rooms to accommodate these new machines. We describe two shielding materials: one made by embedding small pieces of scrap steel in cement, and the other made with cast iron in cement. Both materials produce high-density barriers at low cost using standard construction methods

  2. Radiation protection and shielding design - Strengthening the link

    International Nuclear Information System (INIS)

    Hobson, J.; Cooper, A.

    2005-01-01

    The improvement in quality and flexibility of shielding methods and data has been progressive and beneficial in opening up new opportunities for optimising radiation protection in design. The paper describes how these opportunities can best be seized by taking a holistic view of radiation protection, with shielding design being an important component part. This view is best achieved by enhancing the role of 'shielding assessors' so that they truly become 'radiation protection designers'. The increase in speed and efficiency of shielding calculations has been enormous over the past decades. This has raised the issue of how the assessor's time now can be best utilised; pursuing ever greater precision and accuracy in shielding/dose assessments, or improving the contribution that shielding assessment makes to radiological protection and cost-effective design. It is argued in this paper that the latter option is of great importance and will give considerable benefits. Shielding design needs to form part of a larger radiation protection perspective based on a deep understanding/appreciation of the opportunities and constraints of operators and designers, enabling minimal design iterations, cost optimisation of alternative designs (with a 'lifetime' perspective) and improved realisation of design intent in operations. The future of shielding design development is argued to be not in improving the 'tool-kit', but in enhanced understanding of the 'product' and the 'process' for achieving it. The holistic processes being developed in BNFL to realise these benefits are described in the paper and will be illustrated by case studies. (authors)

  3. Future control room design (modernization of control room systems)

    International Nuclear Information System (INIS)

    Reischl, Ludwig; Freitag, Timo; Dergel, Rene

    2009-01-01

    In the frame of lifetime extension for nuclear power plants the modernization of the complete safety and operational control technology will be digitalized. It is also recommended to modernize the operator facilities, monitoring systems in the control room, the back-up shut-down center and the local control stations. The authors summarize the reasons for the modernization recommendations and discuss possible solutions for display-oriented control rooms. A concept for control room backfitting includes generic requirements, requirements of the local authorities, ergonomic principles information content and information density, and the design process. The backfitting strategy should include a cooperation with the operational personnel, The quality assurance and training via simulator needs sufficient timing during the implementation of the backfitting.

  4. Preliminary radiation shielding design for BOOMERANG

    International Nuclear Information System (INIS)

    Donahue, Richard J.

    2002-01-01

    Preliminary radiation shielding specifications are presented here for the 3 GeV BOOMERANG Australian synchrotron light source project. At this time the bulk shield walls for the storage ring and injection system (100 MeV Linac and 3 GeV Booster) are considered for siting purposes

  5. Survey of shielding calculation parameters in radiotherapy rooms used in the country and its impact in the existing calculation methodologies

    International Nuclear Information System (INIS)

    Japiassu, Fernando Parois

    2013-01-01

    When designing radiotherapy treatment rooms, the dimensions of barriers are established on the basis of American calculation methodologies specifically; NCRP Report N° 49, NCRP Report N° 51, and more recently, NCRP Report N° 151. Such barrier calculations are based on parameters reflecting predictions of treatments to be performed within the room; which, in tum, reftect a specific reality found in a country. There exists, however, a variety of modern radiotherapy techniques, such as Intensity Modulated Radiation Therapy (IMRT); Total Body Irradiation (TBl) and radiosurgery (SRS); where patierits are treated in a much different way than during more conventional treatrnents, which are not taken into account the traditional shielding calculation methodology. This may lead to a faulty design of treattnent rooms. In order to establish a comparison between the methodology used to calculate shielding design and the reality of treatments performed in Brazil, two radiotherapy facilitie were selected, both of them offering traditional and modern treatment techniqued as described above. Data in relation with reatments perfotmed over a period of six (6)months of operations in both institutions were collected. Based on tlis informaton, a new set of realistic parameters required for shielding design was estãblished, whicb in turn allowed for a nwe caculation of barrier thickness for both facilities. The barrier thickness resultaing from this calculation was then compared with the barrier thickness propose as part of the original shielding design, approved by the regulatory authority. First, concerning the public facility, the thickness of all primary barriers proposed in the shielding design was actually larger than the thickness resulting from calculations based on realistic parameters. Second, concerning the private facility, the new data show that the thickness of three out of the four primary barriers described in the project is larger than the thickness oresulting from

  6. Design of radiation shields in nuclear reactor core

    International Nuclear Information System (INIS)

    Mousavi Shirazi, A.; Daneshvar, Sh.; Aghanajafi, C.; Jahanfarnia, Gh.; Rahgoshay, M.

    2008-01-01

    This article consists of designing radiation shields in the core of nuclear reactors to control and restrain the harmful nuclear radiations in the nuclear reactor cores. The radiation shields protect the loss of energy. caused by nuclear radiation in a nuclear reactor core and consequently, they cause to increase the efficiency of the reactor and decrease the risk of being under harmful radiations for the staff. In order to design these shields, by making advantages of the O ppenheim Electrical Network m ethod, the structure of the shields are physically simulated and by obtaining a special algorithm, the amount of optimized energy caused by nuclear radiations, is calculated

  7. Preliminary evaluation of FY98 KALIMER shielding design

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Jae Woon; Kang, Chang Mu; Kim, Young Jin [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-01-01

    This report describes a preliminary evaluation of the shielding design of FY98 KALIMER. The KALIMER shielding design includes the Inner Fixed Shield of a stainless cylinder located inside the support barrel; the Radial PSDRS Shields which are three B{sub 4}C cylinders located outside the support barrel at core level; the Lower IHX shield of a cylindrical B{sub 4}C plate located above the flow guide; and Inner and Outer IHX shields of B{sub 4}C cylinders located inside and outside of the support barrel, respectively. The DORT3.1 two-dimensional transport code was used to evaluate the KALIMER shielding design. The reactor system was represented by four axial zones, each of which was modeled in the R-Z geometry. The KAFAX-F22 library was used in the analyses, which was generated from the JEF-2.2 of OECD/NEA files for LMR applications by KAERI. The performance of the KALIMER shielding design is compared against the shielding design criteria. The results indicate that the support barrel, upper grid plate, and other reactor structures meet the maximum neutron fluence and DPA limits established in the shielding design criteria. Activities of the air effluent in the PSDRS were also evaluated and are shown to satisfy the maximum permissible concentration (MPC) limits in 10 CFR Part 20. In the future, the validation of the DORT model by a detailed three dimensional calculation such as MCNP and the justification of the current shielding design limits are needed. (author). 13 refs., 23 figs., 31 tabs.

  8. Shielding design method for LMFBR validation on the Phenix factor

    International Nuclear Information System (INIS)

    Cabrillat, J.C.; Crouzet, J.; Misrakis, J.; Salvatores, M.; Rado, V.; Palmiotti, G.

    1983-05-01

    Shielding design methods, developed at CEA for shielding calculations find a global validation by the means of Phenix power reactor (250 MWe) measurements. Particularly, the secondary sodium activation of pool type LMFBR such as Super Phenix (1200 MWe) which is subject to strict safety limitation is well calculated by the adapted scheme, i.e. a two dimension transport calculation of shielding coupled to a Monte-Carlo calculation of secondary sodium activation

  9. Protective shielding parameters of diagnostic x-ray rooms in some hospitals in Benue State

    International Nuclear Information System (INIS)

    Agba, E.H.; Gemanam, S.; Sombo, T.

    2011-01-01

    Protective shielding parameters of diagnostic x-ray units at Federal Medical Centre, Makurdi, Baki Hospital, Gboko and Mkar Christian Hospital, Gboko have been determined using a radiation meter, (Inspector, Exp.S.E). The parameters determined include: Operating potential, Workload and Use factors of each diagnostic x-ray room. These parameters were used to estimate the primary and secondary protective barriers for the hospitals. The primary and secondary protective barrier values at Mkar Christian Hospital, Baki Hospital, Gboko and Federal Medical Centre, Makurdi are found to be: 11.0±0.11 x10 -1 mm and 9.0±9x10 -2 mm; 6.0±6.0x10 -1 mm and 6.0±6.0x10 -2 mm; and 7.0±7.0x10 -1 mm and 6.0±6.0x10 -2 mm respectively. The wall thicknesses around the x-ray rooms of the respective hospitals are 300±3.0x1 0 -1 mm for Mkar Christian Hospital and Federal Medical Centre, Makurdi, while that of Baki Hospital, Gboko is 270±2.7x10 -1 mm. The measured wall thicknesses are seen to be adequate protective structural shields on the basis of International NCRP Standards on Structural Shielding.

  10. Optimized design of shields for diagnostic X rays with NCRP 147 technique

    International Nuclear Information System (INIS)

    Gama T, G.

    2006-01-01

    A comparison among the design techniques of shielding for X-ray diagnostic rooms with the NCRP 49 (1976) report technique, AAPM 39 (1993) Y the one of the NCRP 147 (2005) technique. The designs correspond to a room of conventional X-rays, one of fluoroscopy, one of tomography Y one of mammography. In all the cases it demonstrates that the NCRP 49 technique overestimate the shieldings. The causes of the overestimation of the NCRP 49 can be attributed to: a) high values of the work charge that don't consider the spectral fluence of the photons that are present in each room, b) to the differences in the values of the kerma in air without attenuation for the dispersed primary radiation Y of leakage among both reports. (Author)

  11. The design study of the JT-60SU device. No.8. Nuclear shielding and safety design

    Energy Technology Data Exchange (ETDEWEB)

    Miya, Naoyuki; Kikuchi, Mitsuru; Ushigusa, Kenkichi [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment] [and others

    1998-03-01

    Results of nuclear shielding design study and safety analysis for the steady-state tokamak device JT-60SU are described. D-T operation (option) for two years is adopted in addition to ten years operation using deuterium. Design work has been done in accordance with general laws for radioisotopes handling in Japan as a guideline of safety evaluation, which is applied to the operation of present JT-60U device. Optimization of the shielding design for the device structure including vacuum vessel has been presented to meet with allowable limits of biological shielding determined in advance. It is shown that JT-60SU can be operated safely in the present JT-60 experimental building. It is planed to use 100g/year of tritium in D-T operation phase. A concept of multiple -barrier system is applied to the facility design to prevent propagation of tritium, in which the torus hall and the tritium removal room provide the tertiary confinement. From the design of atmosphere detritiation system for accidental tritium release, it is shown that tritium concentration level can be reduced to the allowable level after two weeks with reasonable compact size components. Safety assessment related to activation of coolant/air, and atmospheric tritium effluents are discussed. (author)

  12. Clinic exam room design: present and future.

    Science.gov (United States)

    Freihoefer, Kara; Nyberg, Gary; Vickery, Christine

    2013-01-01

    This article aims to deconstruct various design qualities and strategies of clinic exam rooms, and discuss how they influence users' interaction and behavior in the space. Relevant literature supports the advantages and disadvantages of different design strategies. Annotated exam room prototypes illustrate the design qualities and strategies discussed. Advancements in technology and medicine, along with new legislative policies, are influencing the way care providers deliver care and ultimately clinic exam room designs. The patient-centered medical home model has encouraged primary care providers to make patients more active leaders of their health plan which will influence the overall functionality and configuration of clinic exam rooms. Specific design qualities discussed include overall size, location of doors and privacy curtains, positioning of exam tables, influence of technology in the consultation area, types of seating, and placement of sink and hand sanitizing dispensers. In addition, future trends of exam room prototypes are presented. There is a general lack of published evidence to support design professionals' design solutions for outpatient exam rooms. Future research should investigate such topics as the location of exam tables and privacy curtains as they relate to patient privacy; typical size and location of consultation table as it relates to patient connection and communication; and placement of sinks and sanitization dispensers as they relate to frequency and patterns of usage. Literature review, outpatient, technology, visual privacy.

  13. Analytical solution for shielding in teletherapy rooms with Co60 according to semiempirical equation of attenuation

    International Nuclear Information System (INIS)

    Saez, D.G.; Borroto, M.

    1996-01-01

    The paper presents the parameters for a semiempirical equation of an exponential-polynomial type for the description of the transmission data of the different qualities of the Co-60 radiation in finite means of concrete (2350 kg m -3 ) and lead. This equation and the expression obtained for the relationship of scatter-to-incident exposure, help in the development of a computerized analytical solution of the Simpkin's method for shielding calculations in Co-60 teletherapy rooms. The results were compared with the values offered in the NCRP-49 for the same conditions, obtaining an acceptable correlation. (authors). 8 refs., 2 tabs

  14. A conceptual gamma shield design using the DRP model computation

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, E E [Reactor Department, Nuclear Research Center, Atomic Energy Authority, Cairo (Egypt); Rahman, F A [National Center of Nuclear Safety and Radiation Control, Atomic Energy Authority, Cairo (Egypt)

    1997-12-31

    The purpose of this investigation is to assess basic areas of concern in the development of reactor shielding conceptual design calculations. A spherical shield model composed of low carbon steel and lead have been constructed to surround a Co-60 gamma point source. two alternative configurations have been considered in the model computation. The numerical calculations have been performed using both the ANISN code and DRP model computation together with the DLC 75-Bugle 80 data library. A resume of results for deep penetration in different shield materials with different packing densities is presented and analysed. The results showed that the gamma fluxes attenuation is increased with increasing distribution the packing density of the shield material which reflects its importance of considering it as a safety parameter in shielding design. 3 figs.

  15. Evaluation of neutron doses beyond of primary shielding of rooms housing clinical linear accelerators

    International Nuclear Information System (INIS)

    Rezende, Gabriel Fonseca da Silva

    2011-01-01

    The growing need to build radiotherapy rooms in places with lack of available space leads to the necessity of unconventional solutions for the shielding projects. In most cases, adding metals to the primary barriers is the best way to shield the rooms properly. However, when photons with energies equal to or great than 10 MeV interact with nuclei of materials with high atomic number, neutrons are ejected and can result in a problem of radioprotection both inside and outside the room. Currently, the only empirical formula existing in the literature to assess the dose equivalent due to neutrons beyond the laminated barriers works only under very specific conditions, and a validation of this formula had not yet been done. In this work, the Monte Carlo code MCNPX was used to verify the validity of the above formula for cases of primary barriers containing lead or iron sheets in rooms that house linear accelerators with 10, 15 and 18 MV. Moreover, such a code was used to evaluate the coefficient of neutron production and tenth-value layer for neutrons in concrete, both parameters that directly influence the equation studied. The study results showed that over 90% of the values compared between the formula and the simulations present discrepancies above 100%, which led to conclude that the formula from the literature produces values that do not match the reality. In addition, there were inconsistencies in the parameters that make up the formula, leading to a need to review this formula in order to build a new model that will better represent the real case. (author)

  16. Method for control-room display design

    International Nuclear Information System (INIS)

    Montmayeul, R.

    1988-01-01

    This document describes a method for control-room displays design. It can be used either for isolated display to add to an existing system either for the design of a full system of operator aids. The method is a top-down design with steps of possible iteration. The emphasis is put on display design rather than on system design; system aspects are just mentioned. Advantages of using a method are described [fr

  17. Reassessment of shielding calculations for a room housing a Cesium-137 irradiator

    International Nuclear Information System (INIS)

    Oliveira, Leticia S.; Barbosa, Rugles C.; Rezende, Ana C.B.

    2017-01-01

    This aim of this work is to reassess the shielding calculations for a room that houses an irradiator with cesium-137 ( 137 Cs) source with activity of 444GBq (12Ci). Shielding or barriers have the function of reducing the intensity of the radiation emitted by a radioactive source, are constituted by materials of high atomic number and guarantee the radiological protection in areas occupied by occupationally exposed individuals or by individuals of the public. The barriers located in the direction of the direct beam of radiation are called primary barriers and are thicker. Already the barriers that attenuate the radiation scattered by the radiated surface are called secondary barriers. In the new calculations, the thickness of the primary barrier was determined by model of the point nucleus model and for the secondary barriers, the differential albedo dose model was used. The results obtained show that all secondary barriers were constructed with overestimated thicknesses and that the radiological protection of individuals from the public and occupationally exposed individuals in the areas outside these barriers is guaranteed. The primary barrier was constructed with a thickness 8% smaller than the thickness obtained in the new calculations. In addition to shielding calculations, classification and signaling of adjacent areas were performed, including necessary emergency procedures. The necessary instrumentation for monitoring these areas was also determined. (author)

  18. Reassessment of shielding calculations for a room housing a Cesium-137 irradiator

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Leticia S.; Barbosa, Rugles C., E-mail: leticia.fmufg@gmail.com, E-mail: rbarbosa@cnen.gov.br [Centro Regional de Ciências Nucleares do Centro Oeste (CRCN-CO/CNEN-GO), Abadia de Goiás, GO (Brazil); Rezende, Ana C.B., E-mail: anacbrz@gmail.com [Universidade Federal de Goiás (UFG), Goiânia, GO (Brazil). Escola de Engenharia

    2017-07-01

    This aim of this work is to reassess the shielding calculations for a room that houses an irradiator with cesium-137 ({sup 137}Cs) source with activity of 444GBq (12Ci). Shielding or barriers have the function of reducing the intensity of the radiation emitted by a radioactive source, are constituted by materials of high atomic number and guarantee the radiological protection in areas occupied by occupationally exposed individuals or by individuals of the public. The barriers located in the direction of the direct beam of radiation are called primary barriers and are thicker. Already the barriers that attenuate the radiation scattered by the radiated surface are called secondary barriers. In the new calculations, the thickness of the primary barrier was determined by model of the point nucleus model and for the secondary barriers, the differential albedo dose model was used. The results obtained show that all secondary barriers were constructed with overestimated thicknesses and that the radiological protection of individuals from the public and occupationally exposed individuals in the areas outside these barriers is guaranteed. The primary barrier was constructed with a thickness 8% smaller than the thickness obtained in the new calculations. In addition to shielding calculations, classification and signaling of adjacent areas were performed, including necessary emergency procedures. The necessary instrumentation for monitoring these areas was also determined. (author)

  19. Design of platform for removing screws from LCD display shields

    Science.gov (United States)

    Tu, Zimei; Qin, Qin; Dou, Jianfang; Zhu, Dongdong

    2017-11-01

    Removing the screws on the sides of a shield is a necessary process in disassembling a computer LCD display. To solve this issue, a platform has been designed for removing the screws on display shields. This platform uses virtual instrument technology with LabVIEW as the development environment to design the mechanical structure with the technologies of motion control, human-computer interaction and target recognition. This platform removes the screws from the sides of the shield of an LCD display mechanically thus to guarantee follow-up separation and recycle.

  20. Detailed mechanical design of the LIPAc beam dump radiological shielding

    Energy Technology Data Exchange (ETDEWEB)

    Nomen, Oriol, E-mail: onomen@irec.cat [IREC, Barcelona, Catalonia (Spain); CDEI-UPC, Barcelona, Catalonia (Spain); Martínez, José I.; Arranz, Fernando; Iglesias, Daniel; Barrera, Germán; Brañas, Beatriz [CIEMAT, Madrid (Spain); Ogando, Francisco [UNED, Madrid (Spain); Molla, Joaquín [CIEMAT, Madrid (Spain); Sanmartí, Manel [IREC, Barcelona, Catalonia (Spain)

    2013-10-15

    Highlights: ► Mechanical design of the IFMIF LIPAc beam dump shielding has been performed. ► Lead shutter design performed to shield radiation from beam dump when LIPAc is off. ► External loads, working and dismantling conditions, included as design constraints. -- Abstract: The LIPAc is a 9 MeV, D{sup +} linear prototype accelerator for the validation of the IFMIF accelerator design. The high intensity, 125 mA CW beam is stopped in a copper cone involving a high production of neutrons and gamma radiation and activation of its surface. The beam stopper is surrounded by a shielding to attenuate the resulting radiation so that dose rate values comply with the limits at the different zones of the installation. The shielding includes for that purpose polyethylene rings, water tanks and gray cast iron rings. A lead shutter has also been designed to shield the gamma radiation that comes through the beam tube when the linear accelerator is not in operation, in order to allow access inside the building for maintenance tasks. The present work summarizes the detailed mechanical design of the beam dump shielding and the lead shutter taking into account the design constraints, such as working conditions and other external loads, as well as including provisions for dismantling.

  1. Computer vision based room interior design

    Science.gov (United States)

    Ahmad, Nasir; Hussain, Saddam; Ahmad, Kashif; Conci, Nicola

    2015-12-01

    This paper introduces a new application of computer vision. To the best of the author's knowledge, it is the first attempt to incorporate computer vision techniques into room interior designing. The computer vision based interior designing is achieved in two steps: object identification and color assignment. The image segmentation approach is used for the identification of the objects in the room and different color schemes are used for color assignment to these objects. The proposed approach is applied to simple as well as complex images from online sources. The proposed approach not only accelerated the process of interior designing but also made it very efficient by giving multiple alternatives.

  2. A shielding design for an accelerator-based neutron source for boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hawk, A.E.; Blue, T.E. E-mail: blue.1@osu.edu; Woollard, J.E

    2004-11-01

    Research in boron neutron capture therapy (BNCT) at The Ohio State University Nuclear Engineering Department has been primarily focused on delivering a high quality neutron field for use in BNCT using an accelerator-based neutron source (ABNS). An ABNS for BNCT is composed of a proton accelerator, a high-energy beam transport system, a {sup 7}Li target, a target heat removal system (HRS), a moderator assembly, and a treatment room. The intent of this paper is to demonstrate the advantages of a shielded moderator assembly design, in terms of material requirements necessary to adequately protect radiation personnel located outside a treatment room for BNCT, over an unshielded moderator assembly design.

  3. Control room philosophy: Principles of control room design and control room work

    International Nuclear Information System (INIS)

    Skriver, Jan; Ramberg, Jasmine; Allwin, Pernilla

    2006-01-01

    In order to provide insights for improvement of work in control rooms several factors have to be considered. Knowledge of principles including control room philosophies will guide the recommended improvements. In addition to knowledge about specific principles an advantage for an organization can be an understanding of similarities and policies used in other high risk industry. The report has been developed on the basis of a document analysis of international standards and other guiding documents. (NUREG 0711, ISO 11064, ISO 6385, IEC 60964). In addition to the document analysis which has strived to compare the documents to see similarities in important principals, experience from working with control room design, modifications and evaluations in other high risk industries has pervaded the report. Important principles have been identified which are recommended to be included in a control room philosophy. Many of these are similar to the principles identified in the international standards. An additional principal which is regarded as important is the utilization of Key Performance Indicators (KPI) which can be used as a measure to target preventative means. Further more it is critical that the control room philosophy is easy to access and comprehend for all users. One of the challenges that remain after having developed a control room philosophy is how to utilize it in the daily work situation. It is vital that the document remains as a living document, guiding the continual improvement of the control room in the various life cycle stages

  4. Shielding design for PWR in France

    International Nuclear Information System (INIS)

    Champion, G.; Charransol; Le Dieu de Ville, A.; Nimal, J.C.; Vergnaud, T.

    1983-05-01

    Shielding calculation scheme used in France for PWR is presented here for 900 MWe and 1300 MWe plants built by EDF the French utility giving electricity. Neutron dose rate at areas accessible by personnel during the reactor operation is calculated and compared with the measurements which were carried out in 900 MWe units up to now. Measurements on the first French 1300 MWe reactor are foreseen at the end of 1983

  5. Optimization of the National Ignition Facility primary shield design

    International Nuclear Information System (INIS)

    Annese, C.E.; Watkins, E.F.; Greenspan, E.; Miller, W.F.

    1993-10-01

    Minimum cost design concepts of the primary shield for the National Ignition laser fusion experimental Facility (NIF) are searched with the help of the optimization code SWAN. The computational method developed for this search involves incorporating the time dependence of the delayed photon field within effective delayed photon production cross sections. This method enables one to address the time-dependent problem using relatively simple, time-independent transport calculations, thus significantly simplifying the design process. A novel approach was used for the identification of the optimal combination of constituents that will minimize the shield cost; it involves the generation, with SWAN, of effectiveness functions for replacing materials on an equal cost basis. The minimum cost shield design concept was found to consist of a mixture of polyethylene and low cost, low activation materials such as SiC, with boron added near the shield boundaries

  6. Shielding design of RIKEN RI Beam Factory

    Energy Technology Data Exchange (ETDEWEB)

    Uwamino, Yoshitomo; Fukunishi, Nobuhisa [Institute of Physical and Chemical Research, Wako, Saitama (Japan); Oishi, Koji [Shimizu Corp., Tokyo (Japan)

    2000-03-01

    Construction of the RIKEN RI Beam Factory is started, and the phase 1 will be finished by the end of March 2003. Two ring cyclotrons including one superconducting machine and two Big RIPSs will be constructed in the phase 1. Heavy ions of proton to uranium will be accelerated up to 400 MeV/u (A<40) and 150 MeV/u for uranium at an intensity of 10{sup 13} pps. Neutron production by the 400 MeV/u {sup 20}Ne beam was measured at HIMAC of NIRS and it was used for the source term of the shielding calculations. The deep penetration of high-energy neutrons was calculated by using the ANISN code with the DLC-119/HILO86R group constants and also by using the HETC code. The ANISN results were modified by using the HETC results and the shielding experiment at ISIS, and they were fitted by a simple formula for practical use. High-energy neutron penetrations of slantwise injection and the reflection probabilities of iron slab were calculated with the HETC code, and these results were used for the estimation of the thickness for the iron local shielding of Big RIPSs. Induced radioactivity in the air, accelerator components and the building, and the skyshine effect were also estimated. (author)

  7. Evaluation of radiation protection in x rays room design in diagnostic radiography department in Omdurman locality

    International Nuclear Information System (INIS)

    Adam, Ahmed yusif Abdelrahman

    2013-03-01

    The purpose of this study is conducted in order to evaluate the application of radiation protection in x-ray rooms design in diagnosis radiology department, evaluate personal monitoring devices, to assess primary scatter and leakage radiation dose, to assess monitoring devices if available, in period from March 2013 to August 2013. The design data included room size, control room size, manufacture of equipment, room surrounding areas, workload of all equipment rooms, type of x-ray equipment, radiation worker's in all hospital, number of patient in each shift, structural material and shielding, K vp and m As used in x-ray room department during examination testing. The results of this study show that there is x-ray room design, the design of x-ray equipment is accepted according to the radiation safety institute team of quality control. Also the study shows that the radiation protection devices are available and in a good condition and enough in number. The study shows that there are not personal monitoring devices and services. the radiological technologist are well trained. Also the study investigation the radiation protection in x-ray room in diagnostic department in Omdurman locality. Finally the study shows that there is compact able to ICRP recommended and National quality control in Sudan Atomic Energy Council exception, Alwedad, Abusied and Blue Nile there are have not control room concludes that there is only in relationship hospital have a window without shield.(Author)

  8. Evaluation of the shield calculation adequacy of radiotherapy rooms through Monte Carlo Method and experimental measures

    International Nuclear Information System (INIS)

    Meireles, Ramiro Conceicao

    2016-01-01

    The shielding calculation methodology for radiotherapy services adopted in Brazil and in several countries is that described in publication 151 of the National Council on Radiation Protection and Measurements (NCRP 151). This methodology however, markedly employs several approaches that can impact both in the construction cost and in the radiological safety of the facility. Although this methodology is currently well established by the high level of use, some parameters employed in the calculation methodology did not undergo to a detailed assessment to evaluate the impact of the various approaches considered. In this work the MCNP5 Monte Carlo code was used with the purpose of evaluating the above mentioned approaches. TVLs values were obtained for photons in conventional concrete (2.35g / cm 3 ), considering the energies of 6, 10 and 25 MeV, respectively, first considering an isotropic radiation source impinging perpendicular to the barriers, and subsequently a lead head shielding emitting a shaped beam, in the format of a pyramid trunk. Primary barriers safety margins, taking in account the head shielding emitting photon beam pyramid-shaped in the energies of 6, 10, 15 and 18 MeV were assessed. A study was conducted considering the attenuation provided by the patient's body in the energies of 6,10, 15 and 18 MeV, leading to new attenuation factors. Experimental measurements were performed in a real radiotherapy room, in order to map the leakage radiation emitted by the accelerator head shielding and the results obtained were employed in the Monte Carlo simulation, as well as to validate the entire study. The study results indicate that the TVLs values provided by (NCRP, 2005) show discrepancies in comparison with the values obtained by simulation and that there may be some barriers that are calculated with insufficient thickness. Furthermore, the simulation results show that the additional safety margins considered when calculating the width of the primary

  9. Gamma-ray shielding design and performance test of WASTEF

    International Nuclear Information System (INIS)

    Matsumoto, Seiichiro; Aoyama, Saburo; Tashiro, Shingo; Nagai, Shiro

    1984-06-01

    The Waste Safety Testing Facility (WASTEF) was planned in 1978 to test the safety performance of HLW vitrified forms under the simulated conditions of long term storage and disposal, and completed in August 1981. The designed feature of the facility is to treat the vitrified forms contain actual high-level wastes of 5 x 10 4 Ci in maximum with 5 units of concrete shilded hot cells (3 units : Bate-Gamma cells, 2 units : Alpha-Gamma cells) and one units of Alpha-Gamma lead shielded cell, and to store radioactivity of 10 6 Ci in maximum. The safety performance of this facility is fundamentally maintained with confinement of radioactivity and shielding of the radiation. This report describes the method of gamma-ray shielding design, evaluation of the shielding test performed by using sealded gamma-ray sources(Co-60). (author)

  10. Shielding design study of the demonstration fast breeder reactor. 2. Shielding design on the basis of the JASPER analysis

    International Nuclear Information System (INIS)

    Suzuoki, Zenro; Tabayashi, Masao; Handa, Hiroyuki; Iida, Masaaki; Takemura, Morio

    2000-01-01

    Conceptual shielding design has been performed for the Demonstration Fast Breeder Reactor (DFBR) to achieve further optimization and reduction of the plant construction cost. The design took into account its implications in overall plant configuration such as reduction of shields in the core, adoption of fission gas plenum in the lower portion of fuel assemblies, and adoption of gas expansion modules. Shielding criteria applied for the design are to secure fast neutron fluence on in-vessel structures as well as responses of the nuclear instrumentation system and to restrict secondary sodium activation. The design utilized the cross sections and the one- and two-dimensional discrete ordinates transport codes, whose verification had been performed by the JASPER experiment analysis. Correction factors yielded by the JASPER analysis were applied to the design calculations to obtain design values with improved accuracy. Design margins, which are defined by the ratios of the design criteria to the design values, were more than two for all shielding issues of interest, showing the adequacy of the shielding design of the DFBR. (author)

  11. Cooling Performance of TBM-shield Designed for Manufacturability

    International Nuclear Information System (INIS)

    Park, Seong Dae; Lee, Dong Won; Kim, Dong Jun; Yoon, Jae Sung; Ahn, Mu Young

    2016-01-01

    Helium cooled ceramic reflector (HCCR) test blanket module (TBM) is composed of four sub-modules and a common back manifold (BM). The associated shield is a water-cooled 316L(N)-IG block with internal cooling channels. The purpose of the TBM-shield is to make the condition with the allowable neutron flux and dose rate level. The radially continuous layers of water and structure were configured. The main purpose of the shield is to reduce the neutron flux by absorbing the neutron in the structure. The water could act as the moderator and cool down the structure which is heated due to the reaction with the neutrons. The moderated neutrons are easily absorbed by the structure. It could meet the criteria for the minimum neutron flux by increasing the thickness of structure. The formation of inside cooling channel in the TBM-shield should be considered while maintaining the allowable temperature range. In this work, a manufacturing process including the formation of inside cooling channel was presented. Current design and thermal analysis results for the TBM-shield were presented. The geometry of the shield blocks was considerably changed. The coolant channel was exposed to the outer surface of the TBM-shield. The overall manufacturing process is simplified compared with the previous process of CD model

  12. Cooling Performance of TBM-shield Designed for Manufacturability

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seong Dae; Lee, Dong Won; Kim, Dong Jun; Yoon, Jae Sung [KAERI, Daejeon (Korea, Republic of); Ahn, Mu Young [NFRI, Daejeon (Korea, Republic of)

    2016-05-15

    Helium cooled ceramic reflector (HCCR) test blanket module (TBM) is composed of four sub-modules and a common back manifold (BM). The associated shield is a water-cooled 316L(N)-IG block with internal cooling channels. The purpose of the TBM-shield is to make the condition with the allowable neutron flux and dose rate level. The radially continuous layers of water and structure were configured. The main purpose of the shield is to reduce the neutron flux by absorbing the neutron in the structure. The water could act as the moderator and cool down the structure which is heated due to the reaction with the neutrons. The moderated neutrons are easily absorbed by the structure. It could meet the criteria for the minimum neutron flux by increasing the thickness of structure. The formation of inside cooling channel in the TBM-shield should be considered while maintaining the allowable temperature range. In this work, a manufacturing process including the formation of inside cooling channel was presented. Current design and thermal analysis results for the TBM-shield were presented. The geometry of the shield blocks was considerably changed. The coolant channel was exposed to the outer surface of the TBM-shield. The overall manufacturing process is simplified compared with the previous process of CD model.

  13. Dynamical cancellation of pulse-induced transients in a metallic shielded room for ultra-low-field magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zevenhoven, Koos C. J.; Ilmoniemi, Risto J.; Dong, Hui; Clarke, John

    2015-01-01

    Pulse-induced transients such as eddy currents can cause problems in measurement techniques where a signal is acquired after an applied preparatory pulse. In ultra-low-field magnetic resonance imaging, performed in magnetic fields typically of the order of 100 μT, the signal-to-noise ratio is enhanced in part by prepolarizing the proton spins with a pulse of much larger magnetic field and in part by detecting the signal with a Superconducting QUantum Interference Device (SQUID). The pulse turn-off, however, can induce large eddy currents in the shielded room, producing an inhomogeneous magnetic-field transient that both seriously distorts the spin dynamics and exceeds the range of the SQUID readout. It is essential to reduce this transient substantially before image acquisition. We introduce dynamical cancellation (DynaCan), a technique in which a precisely designed current waveform is applied to a separate coil during the later part and turn off of the polarizing pulse. This waveform, which bears no resemblance to the polarizing pulse, is designed to drive the eddy currents to zero at the precise moment that the polarizing field becomes zero. We present the theory used to optimize the waveform using a detailed computational model with corrections from measured magnetic-field transients. SQUID-based measurements with DynaCan demonstrate a cancellation of 99%. Dynamical cancellation has the great advantage that, for a given system, the cancellation accuracy can be optimized in software. This technique can be applied to both metal and high-permeability alloy shielded rooms, and even to transients other than eddy currents

  14. Problems related to design and construction of industrial radiography exposure room - an experience

    International Nuclear Information System (INIS)

    Siti Madiha Muhammad Amir; Mohd Khairi Mohd Said; Abdul Nassir Ibrahim; Ab Razak Hamzah

    2009-01-01

    In Non-Destructive Testing (NDT), especially in radiography method, inspections of components are executed either on-site or in-house. For in-house inspections, work must be performed in a specially constructed exposure room. The design of the exposure room must be according to specific requirements described in various documents related to radiation safety. Stringent requirements specified for the exposure room is for the purpose of ensuring the safety of public and radiation workers. These requirements are never compromised. One of the AELB requirements that need to be complied is that the permissible dose limit anywhere outside the room must be less than 0.25 mR/hr. In designing and constructing the exposure room, many factors must be taken into account such as shielding thickness, density of shielding, thickness of lead door, the roof design of the exposure room and many more. This paper highlights problems encountered and the considerations taken to design and construct the exposure room so that the exposure room will comply with the permissible dose limit set by the regulatory body. (Author)

  15. Production of an economic high-density concrete for shielding megavoltage radiotherapy rooms and nuclear reactors

    International Nuclear Information System (INIS)

    Mortazavi, S. M. J.; Mosleh-Shirazi, M. A.; Maheri, M. R.; Haji-pour, A.; Yousefnia, H.; Zolghadri, S.

    2007-01-01

    In megavoltage radiotherapy rooms, ordinary concrete is usually used due to its low construction costs, although higher density concrete are sometimes used, as well. The use of high-density concrete decreases the required thickness of the concrete barrier; hence, its disadvantage is its high cost. In a nuclear reactor, neutron radiation is the most difficult to shield. A method for production of economic high-density concrete witt, appropriate engineering properties would be very useful. Materials and Methods: Galena (Pb S) mineral was used to produce of a high-density concrete. Galena can be found in many parts of Iran. Two types of concrete mixes were produced. The water-to-concrete (w/c) ratios of the reference and galena concrete mixes were 0.53 and 0.25, respectively. To measure the gamma radiation attenuation of Galena concrete samples, they were exposed to a narrow beam of gamma rays emitted from a cobalt-60 therapy unit. Results: The Galena mineral used in this study had a density of 7400 kg/m 3 . The concrete samples had a density of 4800 kg/m 3 . The measured half value layer thickness of the Galena concrete samples for cobalt 60 gamma rays was much less than that of ordinary concrete (2.6 cm compared to 6.0 cm). Furthermore, the galena concrete samples had significantly higher compressive strength (500 kg/cm 2 compared to 300 kg/cm 2 ). Conclusion: The Galena concrete samples made in our laboratories had showed good shielding/engineering properties in comparison with all samples made by using high-density materials other than depleted uranium. Based on the preliminary results, Galena concrete is maybe a suitable option where high-density concrete is required in megavoltage radiotherapy rooms as well as nuclear reactors

  16. Design of auxiliary shield for remote controlled metallographic microscope

    International Nuclear Information System (INIS)

    Matsui, Hiroki; Okamoto, Hisato

    2014-06-01

    The remote controlled optical microscope installed in the lead cell at the Reactor Fuel Examination Facility (RFEF) in Japan Atomic Energy Agency (JAEA) has been upgraded to a higher performance unit to study the effect of the microstructural evolution in clad material on the high burn-up fuel behavior under the accident condition. The optical pass of the new microscope requires a new through hole in the shielding lead wall of the cell. To meet safety regulations, auxiliary lead shieldings were designed to cover the lost shielding function of the cell wall. Particle and Heavy Ion Transport Code System (PHITS) was used to calculate and determine the shape and setting positions of the shielding unit. Seismic assessments of the unit were also performed. (author)

  17. Fusion Engineering Device (FED) first wall/shield design

    International Nuclear Information System (INIS)

    Sager, P.H.; Fuller, G.; Cramer, B.; Davisson, J.; Haines, J.; Kirchner, J.

    1981-01-01

    The torus of the Fusion Engineering Device (FED) is comprised of the bulk shield and its associated spool lstructure and support system, the first wall water-cooled panel and armor systems, and the pumped limiter. The bulk shielding is provided by ten shield sectors that are installed in the spool structure in such a way as to permit extraction of the sectors through the openings between adjacent toroidal field coils with a direct radial movement. The first wall armor is installed on the inboard and top interior walls of these sectors, and the water-cooled panels are installed on the outboard interior walls and the pumped limiter in the bottom of the sectors. The overall design of the first wall and shield system is described in this paper

  18. Radiation shielding design for a hot repair facility

    International Nuclear Information System (INIS)

    Courtney, J.C.; Dwight, C.C.

    1991-01-01

    A new repair and decontamination area is being built to support operations at the demonstration fuel cycle facility for the Integral Fast Reactor program at Argonne National Laboratory's site at the Idaho National Engineering Laboratory. Provisions are made for remote, glove wall, and contact maintenance on equipment removed from hot cells where spent fuel will be electrochemically processed and recycled to the Experimental Breeder Reactor-II. The source for the shielding design is contamination from a mix of fission and activation products present on items removed from the hot cells. The repair facility also serves as a transfer path for radioactive waste produced by processing operations. Radiation shields are designed to limit dose rates to no more than 5 microSv h-1 (0.5 mrem h-1) in normally occupied areas. Point kernel calculations with buildup factors have been used to design the shielding and to position radiation monitors within the area

  19. Neutron shielding and its impact on the ITER machine design

    International Nuclear Information System (INIS)

    Daenner, W.; El Guebaly, L.; Sawan, M.; Gohar, Y.; Maki, K.; Rado, V.; Schchipakin, O.; Zimin, S.

    1991-01-01

    This paper describes the efforts made in the frame of the ITER project to analyze the shielding of the superconducting magnets. First, the radiation limits to be achieved are specified as well as the neutron source in terms of wall loading on the first wall of the machine. Then the general shield concept is explained, including the most essential details of the various shield components. A brief section is devoted to the calculational tools, the data base, and the safety factors to be applied to the results obtained. The neutronics models of four different configurations are summarized as they were used to study the most critical parts of the machine. This section is followed by a presentation of the most important results from one-, two- and three-dimensional calculations. They are given for both the reference design and an improved one in which the critical regions are reinforced with respect to their shielding capability. It is concluded that the ITER shield layout just marginally meets the stated limits provided that some tungsten is included in the critical regions. A slight revision of the overall machine dimensions with the aim to achieve a less complex shield and a higher margin with respect to the limits is, however, seen the better solution. (orig.)

  20. Developments in shielding and criticality assessment for cask design

    International Nuclear Information System (INIS)

    Watmough, M.H.; Cooper, A.J.; Croxford, R.W.

    1993-01-01

    This paper presents recent highlights from the shielding and criticality methods development programme that are of relevance to cask design. Specifically, the following points emerge: 1) the preparation of a licence application based upon UK methods and data used in a standardized fissile depletion and plutonium production model has been completed; 2) the assumptions used in the modelling of granules of broken fuel within the transport package following a postulated impact accident have been revised thereby allowing less pessimistic assessments to be performed; 3) enhancements are being made to the software used for shielding and criticality analysis enabling a more cost effective design service to be provided. These ongoing developments clearly show the activity to extend the scope of assessments while increasing the physical realism of the models. Through these developments BNFL continues to offer a comprehensive and cost effective shielding and criticality analysis service as part of its worldwide fuel transport business. (J.P.N.)

  1. Configuration Design of Detector Shielding for Gamma Prompt Analysis

    International Nuclear Information System (INIS)

    Elin-Nuraini; Darsono; Elisabeth

    2000-01-01

    Configuration on design of detector shielding for gamma prompt analysishas been performed. The aim of this design is to obtain effective shieldingmaterial and configuration that able to protect the detector for fastneutron. The result shown that detector shielding configuration that obtainedby configuration of water and concrete, would be able to absorb fast neutronup to 99.5 %. The neutron flux that passed through shielding configuration is2.4 x 10 3 n/cm 2 dt, in the detector position of 60 cm (forward neutron beamdirection) on the X axis and 30 cm (side ward neutron beam direction) on theZ axis of target. On this position (60,30) counting result was 104358 for Pbcollimator and 246652 for PVC collimator. From examination result shown thatthe weight of silicon is in order 175 gram. (author)

  2. Poster - 28: Shielding of X-ray Rooms in Ontario in the Absence of Best Practice

    Energy Technology Data Exchange (ETDEWEB)

    Frimeth, Jeff; Richer, Jeff; Nesbitt, James [Xspect Inc., Windsor Regional Hospital, XRCT Ltd. (Canada)

    2016-08-15

    This poster will be strictly based on the Healing Arts Radiation Protection (HARP) Act, Regulation 543 under this Act (X-ray Safety Code), and personal communication the presenting author has had. In Ontario, the process of approval of an X-ray machine installation by the Director of the X-ray Inspection Service (XRIS) follows a certain protocol. Initially, the applicant submits a series of forms, including recommended shielding amounts, in order to satisfy the law. This documentation is then transferred to a third-party vendor (i.e. a professional engineer – P.Eng.) outsourced by the Ministry of Health and Long-term Care (MOHLTC). The P.Eng. then evaluates the submitted documentation for appropriate fulfillment of the HARP Act and Reg. 543 requirements. If the P.Eng.’s evaluation of the documentation is to their satisfaction, the XRIS is then notified. Finally, the Director will then issue a letter of approval to install the equipment at the facility. The methodology required to be used by the P.Eng. in order to determine the required amounts of protective barriers, and recommended to be used by the applicant, is contained within Safety Code 20A. However, Safety Code 35 has replaced the obsolete Safety Code 20A document and employs best practices in shielding design. This talk will focus further on specific intentions and limitations of Safety Code 20A. Furthermore, this talk will discuss the definition of the “practice of professional engineering” in Ontario. COMP members who are involved in shielding design are strongly encouraged to attend.

  3. Poster - 28: Shielding of X-ray Rooms in Ontario in the Absence of Best Practice

    International Nuclear Information System (INIS)

    Frimeth, Jeff; Richer, Jeff; Nesbitt, James

    2016-01-01

    This poster will be strictly based on the Healing Arts Radiation Protection (HARP) Act, Regulation 543 under this Act (X-ray Safety Code), and personal communication the presenting author has had. In Ontario, the process of approval of an X-ray machine installation by the Director of the X-ray Inspection Service (XRIS) follows a certain protocol. Initially, the applicant submits a series of forms, including recommended shielding amounts, in order to satisfy the law. This documentation is then transferred to a third-party vendor (i.e. a professional engineer – P.Eng.) outsourced by the Ministry of Health and Long-term Care (MOHLTC). The P.Eng. then evaluates the submitted documentation for appropriate fulfillment of the HARP Act and Reg. 543 requirements. If the P.Eng.’s evaluation of the documentation is to their satisfaction, the XRIS is then notified. Finally, the Director will then issue a letter of approval to install the equipment at the facility. The methodology required to be used by the P.Eng. in order to determine the required amounts of protective barriers, and recommended to be used by the applicant, is contained within Safety Code 20A. However, Safety Code 35 has replaced the obsolete Safety Code 20A document and employs best practices in shielding design. This talk will focus further on specific intentions and limitations of Safety Code 20A. Furthermore, this talk will discuss the definition of the “practice of professional engineering” in Ontario. COMP members who are involved in shielding design are strongly encouraged to attend.

  4. Modern control room design experience and speculation

    International Nuclear Information System (INIS)

    Smith, J.E.

    1993-01-01

    Can operators trained to use conventional control panels readily adapt to CRT based control rooms? Does automation make the design of good man-machine interfaces more or less difficult? In a conventional, hard-wired control room is the operator's peripheral vision always an asset and how can one do better in a CRT based control room? Are Expert System assisted man-machine interfaces a boon or a bust? This paper explores these questions in the light of actual experience with advanced power plant control environments. This paper discusses how automation has in fact simplified the problem of ensuring that the operator has at all times a clear understanding of the plant state. The author contends that conventional hard-wired control rooms are very poor at providing the operator with a good overview of the plant status particularly under startup, or upset conditions and that CRT-based control rooms offer an opportunity for improvement. Experience with some early attempts at this are discussed together with some interesting proposals from other authors. Finally the paper discusses the experience to date with expert system assisted man-machine interfaces. Although promising for the future progress has been slow. The amount of knowledge research required is often formidable and consequently costly. Often when an adequate knowledge base is finally acquired it turns out to be better to use it to increase the level of automation and thus simplify the operator's task. The risks are not any greater and automation offers more consistent operation. It is important also to carefully distinguish between expert system assisted display selection and expert system operator guidance. The first is intended to help the operator in his quest for information. The second attempts to guide the operator actions. The good and the bad points of each of these approaches is discussed

  5. Neutron streaming analysis for shield design of FMIT Facility

    International Nuclear Information System (INIS)

    Carter, L.L.

    1980-12-01

    Applications of the Monte Carlo method have been summarized relevant to neutron streaming problems of interest in the shield design for the FMIT Facility. An improved angular biasing method has been implemented to further optimize the calculation of streaming and this method has been applied to calculate streaming within a double bend pipe

  6. Radiological shielding of low power compact reactor: calculation and design

    International Nuclear Information System (INIS)

    Marino, Raul

    2004-01-01

    The development of compact reactors becoming a technology that offers great projection and innumerable use possibilities, both in electricity generation and in propulsion.One of the requirements for the operation of this type of reactor is that it must include a radiological shield that will allow for different types of configurations and that, may be moved with the reactor if it needs to be transported.The nucleus of a reactor emits radiation, mainly neutrons and gamma rays in the heat of power, and gamma radiation during the radioactive decay of fission products.This radiation must be restrained in both conditions of operation to avoid it affecting workers or the public.The combination of different materials and properties in layers results in better performance in the form of a decrease in radiation, hence causing the dosage outside the reactor, whether in operation or shut down, to fall within the allowed limits.The calculations and design of radiological shields is therefore of paramount importance in reactor design.The choice of material and the design of the shield have a strong impact on the cost and the load capacity, the latter being one of the characteristics to optimize.The imposed condition of design is that the reactor can be transported together with the decay shield in a standard container of 40 foot [es

  7. Radiation streaming: the continuing problem of shield design

    International Nuclear Information System (INIS)

    Avery, A.F.

    1977-01-01

    The practical problems of shield design are reviewed and the major difficulties are shown to be those associated with streaming problems. The situations in which streaming occurs in various types of reactor are described including LMFBR's and fusion devices, and examples are given of ways in which the problems have been solved

  8. Shielding calculation techniques used in the design of storage systems

    International Nuclear Information System (INIS)

    Wang, S.S.; Massey, J.V.

    1986-01-01

    The shielding design and analysis of a concrete modular spent fuel storage system are discussed. Particular attention is given to comparing various computation techniques in determining bulk shielding thickness, and also in dealing with the radiation streaming effect through the air exist penetration openings in the module. Three computer codes QADMOD, ANISN, and DOT-IV were used to solve the same problem. In addition, hand albedo calculation were done to augment the result of the QADMOD calculation to properly deal with the surface scattering

  9. Optimization of thermal design for nitrogen shield of JET cryopump

    International Nuclear Information System (INIS)

    Baxi, C.B.; Obert, W.

    1991-11-01

    The reference design of JET cryopump nitrogen shield consists of an outer section made of copper chevrons fastened to two cooling tubes and an inner stainless steel section and backing plate with two cooling tubes. These tubes are fed in a parallel flow arrangement. The inlet flow is divided into two parallel paths so that both tubes on either section are always at the same temperature. This arrangement was selected due to concern about conduction between warm and cold parts of the shield during cooldown transients. If the heat loads are unequal, such a parallel flow arrangement can result in flow starvation in the path with higher heat load. This will cause large temperature differences and, ultimately, structural failure. Hence, an analysis was undertaken to investigate the conduction effects in the shield for other flow arrangements. 4 refs., 8 figs

  10. Biological shield around the neutral beam injector ducts in the ITER conceptual design

    International Nuclear Information System (INIS)

    Maki, Koichi; Takatsu, Hideyuki; Satoh, Satoshi; Seki, Yasushi

    1994-01-01

    There are gaps between the toroidal field coils and neutral beam injector (NBI) duct wall for the thermal insulator in tokamak reactors such as ITER (International Thermonuclear Experimental Reactor). Neutrons stream through the duct, and some of them penetrate the wall and stream through the gaps. These neutrons activate the materials composing the duct wall, toroidal field coil (TFC) case and cryostat wall surfaces. The dose rate is enhanced just outside the cryostat around the ducts in the reactor room after reactor operation by activation. We investigated the gamma-ray dose rate just outside the cryostat after shutdown due to gamma-rays from activity induced by the neutrons streaming through the gaps. By evaluating the difference between the dose rate in models with and without gaps, we decided whether the thickness of the cryostat as biological shielding is sufficient or not. From these investigations, we recommend a cryostat design suitable for radiation shielding. Dose rates after shutdown at a point just outside the cryostat around the NBI ducts in the model with gaps are two orders larger than those without gaps. The value at this point is approximately 400 mrem h -1 (4 mSv h -1 ), which is two orders larger than the design value for workers to enter the reactor room. In order to reduce the dose rate after shutdown, a method of providing the shielding function of the cryostat is suggested. ((orig.))

  11. A Designed Room Temperature Multilayered Magnetic Semiconductor

    Science.gov (United States)

    Bouma, Dinah Simone; Charilaou, Michalis; Bordel, Catherine; Duchin, Ryan; Barriga, Alexander; Farmer, Adam; Hellman, Frances; Materials Science Division, Lawrence Berkeley National Lab Team

    2015-03-01

    A room temperature magnetic semiconductor has been designed and fabricated by using an epitaxial antiferromagnet (NiO) grown in the (111) orientation, which gives surface uncompensated magnetism for an odd number of planes, layered with the lightly doped semiconductor Al-doped ZnO (AZO). Magnetization and Hall effect measurements of multilayers of NiO and AZO are presented for varying thickness of each. The magnetic properties vary as a function of the number of Ni planes in each NiO layer; an odd number of Ni planes yields on each NiO layer an uncompensated moment which is RKKY-coupled to the moments on adjacent NiO layers via the carriers in the AZO. This RKKY coupling oscillates with the AZO layer thickness, and it disappears entirely in samples where the AZO is replaced with undoped ZnO. The anomalous Hall effect data indicate that the carriers in the AZO are spin-polarized according to the direction of the applied field at both low temperature and room temperature. NiO/AZO multilayers are therefore a promising candidate for spintronic applications demanding a room-temperature semiconductor.

  12. Accelerator shield design of KIPT neutron source facility

    International Nuclear Information System (INIS)

    Zhong, Z.; Gohar, Y.

    2013-01-01

    Argonne National Laboratory (ANL) of the United States and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on the design development of a neutron source facility at KIPT utilizing an electron-accelerator-driven subcritical assembly. Electron beam power is 100 kW, using 100 MeV electrons. The facility is designed to perform basic and applied nuclear research, produce medical isotopes, and train young nuclear specialists. The biological shield of the accelerator building is designed to reduce the biological dose to less than 0.5-mrem/hr during operation. The main source of the biological dose is the photons and the neutrons generated by interactions of leaked electrons from the electron gun and accelerator sections with the surrounding concrete and accelerator materials. The Monte Carlo code MCNPX serves as the calculation tool for the shield design, due to its capability to transport electrons, photons, and neutrons coupled problems. The direct photon dose can be tallied by MCNPX calculation, starting with the leaked electrons. However, it is difficult to accurately tally the neutron dose directly from the leaked electrons. The neutron yield per electron from the interactions with the surrounding components is less than 0.01 neutron per electron. This causes difficulties for Monte Carlo analyses and consumes tremendous computation time for tallying with acceptable statistics the neutron dose outside the shield boundary. To avoid these difficulties, the SOURCE and TALLYX user subroutines of MCNPX were developed for the study. The generated neutrons are banked, together with all related parameters, for a subsequent MCNPX calculation to obtain the neutron and secondary photon doses. The weight windows variance reduction technique is utilized for both neutron and photon dose calculations. Two shielding materials, i.e., heavy concrete and ordinary concrete, were considered for the shield design. The main goal is to maintain the total

  13. Safety aspects and shield design of a Poton irradiator

    International Nuclear Information System (INIS)

    Mehta, S.K.; Nayak, A.R.; Bongirwar, D.R.; Modi, R.K.; Ramkumar, M.S.

    1998-01-01

    An irradiation plant, POTON, for irradiation of potatoes and onions is being set up at Nashik. Shield design and safety features of this plant incorporate some novel and innovative features like a compact cell, curved cell boundaries for smooth conveyor movement though the cell labyrinth and conform to ICRP and AERB design safety requirements. The safety features include multiple safety interlocks, audio-visual alarms, scram switches and trip wire for avoiding accidental exposures. (author)

  14. New trends in shielding designs for PWRs in France

    International Nuclear Information System (INIS)

    Champion, G.; Forestier, J.; Arbelot, E.

    1985-01-01

    Various engineering solutions to confinement of the stray neutron fields will be incorporated into the design of the 1450 MWe Chooz B-1 (Ardennes B-1) PWR, the first unit of the new N4 program in France. The reactor is in the early stages of construction. These engineering solutions are the results of many shielding configuration studies performed prior to actual design. The solutions and the calculation methodologies are discussed

  15. If additional shielding required for the linear accelerator room when modern treatment techniques are intensively used

    International Nuclear Information System (INIS)

    Miller, Albert V.; Atkocius, Vydmantas; Aleknavicius, Eduardas

    2001-01-01

    Full text: Introduction - When the new linear accelerator is to be installed in radiotherapy department the responsible personnel should perform necessary estimations and calculations of the protective barriers for the accelerator treatment room. These methods are described in details in literature. However, if modern treatment techniques are planned to be intensively used on this machine, additional concern rises regarding adequacy of these calculations. The new Saturne-43 linear accelerator with three photon energies of 8, 15 and 25 MV recently installed at our department was, planned to be used for conventional treatment techniques as well as for conformal and total body treatments. The method of conformal therapy generally employs more small fields per one treated patient than conventional techniques. It leads to the use of more linear accelerator monitor units for the average treatment. It was estimated that 'beam on' time of an accelerator to deliver the same dose to the tumor is up to 3 times more than for conventional methods. The total body technique contribute to the extra time on of an accelerator because of extended distance to the dose prescription point. Altogether intensive clinical use of these modern techniques will noticeably increase 'beam on' time of an accelerator and rise question regarding validity of the traditionally calculated shielding of the treatment room. Materials and methods - IAEA-TECDOC-1040 and NCRP Report No 49 suggest considering three main components incident on the protective barriers: direct radiation, scatter radiation and leakage radiation. The formulas for these components are similar and dose equivalent limits are proportional to the workload. For the conventional treatments workloads of direct, scattered and leakage radiation are equal and calculated by the division of total prescribed dose (for all treated per week patients) to the machine isocenter to average tissue maximum ratio. These workloads for conformal and TBI

  16. Electron accelerator shielding design of KIPT neutron source facility

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Zhao Peng; Gohar, Yousry [Argonne National Laboratory, Argonne (United States)

    2016-06-15

    The Argonne National Laboratory of the United States and the Kharkov Institute of Physics and Technology of the Ukraine have been collaborating on the design, development and construction of a neutron source facility at Kharkov Institute of Physics and Technology utilizing an electron-accelerator-driven subcritical assembly. The electron beam power is 100 kW using 100-MeV electrons. The facility was designed to perform basic and applied nuclear research, produce medical isotopes, and train nuclear specialists. The biological shield of the accelerator building was designed to reduce the biological dose to less than 5.0e-03 mSv/h during operation. The main source of the biological dose for the accelerator building is the photons and neutrons generated from different interactions of leaked electrons from the electron gun and the accelerator sections with the surrounding components and materials. The Monte Carlo N-particle extended code (MCNPX) was used for the shielding calculations because of its capability to perform electron-, photon-, and neutron-coupled transport simulations. The photon dose was tallied using the MCNPX calculation, starting with the leaked electrons. However, it is difficult to accurately tally the neutron dose directly from the leaked electrons. The neutron yield per electron from the interactions with the surrounding components is very small, ∼0.01 neutron for 100-MeV electron and even smaller for lower-energy electrons. This causes difficulties for the Monte Carlo analyses and consumes tremendous computation resources for tallying the neutron dose outside the shield boundary with an acceptable accuracy. To avoid these difficulties, the SOURCE and TALLYX user subroutines of MCNPX were utilized for this study. The generated neutrons were banked, together with all related parameters, for a subsequent MCNPX calculation to obtain the neutron dose. The weight windows variance reduction technique was also utilized for both neutron and photon dose

  17. A survey of Alberta physicians' use of and attitudes toward face masks and face shields in the operating room setting.

    Science.gov (United States)

    Davis, Philip J; Spady, Donald; Forgie, Sarah E D

    2007-09-01

    There is little evidence that surgical mask use by physicians in the operating room (OR) reduces surgical site infections (SSIs), but masks do protect the wearer from potentially infectious splashes. Face shields offer even more protection because they cover the eyes, but they may be perceived as offering less protection to the patient than do masks. The objectives of this study were to ascertain if there were predictors to determine which OR physicians are continuing to use masks and what their reasons are for doing so, and which OR physicians would accept face shields and their reasons for doing so. We surveyed the province of Alberta's surgeons, general practice (GP) surgeons, anesthesiologists, and GP anesthetists to determine how many physicians in the OR wear surgical masks, their reasons for wearing surgical masks (ethical, legal, protection of the patient, protection of the wearer), and if they believe that face shields offer more protection to the patient or to the wearer. We also sought to examine which demographic factors affected their responses. The data were examined with chi(2) analysis to assess the relationships of age and practitioner type, and for various outcome variables. A significance level of P masks; masks are worn to prevent the spread of disease, not because it is tradition to do so; masks protect the wearer more than do face shields; and wearing face shields alone will subject the patient to higher rates of SSIs. Surgeons are more likely than are anesthesiologists to wear surgical masks in the OR and wear a surgical mask and a face shield if the patient has risk factors for a blood borne infection. According to our survey, age and profession were the most important variables that affected the potential use of surgical masks and face shields. Younger OR physicians likely would be amenable to using face shields in addition to masks in the OR to protect themselves from exposure to blood or bodily fluids.

  18. Piping structural design for the ITER thermal shield manifold

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Chang Hyun, E-mail: chnoh@nfri.re.kr [ITER Korea, National Fusion Research Institute, Daejeon 305-333 (Korea, Republic of); Chung, Wooho, E-mail: whchung@nfri.re.kr [ITER Korea, National Fusion Research Institute, Daejeon 305-333 (Korea, Republic of); Nam, Kwanwoo; Kang, Kyoung-O. [ITER Korea, National Fusion Research Institute, Daejeon 305-333 (Korea, Republic of); Bae, Jing Do; Cha, Jong Kook [Korea Marine Equipment Research Institute, Busan 606-806 (Korea, Republic of); Kim, Kyoung-Kyu [Mecha T& S, Jinju-si 660-843 (Korea, Republic of); Hamlyn-Harris, Craig; Hicks, Robby; Her, Namil; Jun, Chang-Hoon [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2015-10-15

    Highlights: • We finalized piping design of ITER thermal shield manifold for procurement. • Support span is determined by stress and deflection limitation. • SQP, which is design optimization method, is used for the pipe design. • Benchmark analysis is performed to verify the analysis software. • Pipe design is verified by structural analyses. - Abstract: The thermal shield (TS) provides the thermal barrier in the ITER tokamak to minimize heat load transferred by thermal radiation from the hot components to the superconducting magnets operating at 4.2 K. The TS is actively cooled by 80 K pressurized helium gas which flows from the cold valve box to the cooling tubes on the TS panels via manifold piping. This paper describes the manifold piping design and analysis for the ITER thermal shield. First, maximum allowable span for the manifold support is calculated based on the simple beam theory. In order to accommodate the thermal contraction in the manifold feeder, a contraction loop is designed and applied. Sequential Quadratic Programming (SQP) method is used to determine the optimized dimensions of the contraction loop to ensure adequate flexibility of manifold pipe. Global structural behavior of the manifold is investigated when the thermal movement of the redundant (un-cooled) pipe is large.

  19. ITER blanket module shield block design and analysis

    International Nuclear Information System (INIS)

    Mitin, D.; Khomyakov, S.; Razmerov, A.; Strebkov, Yu.

    2008-01-01

    This paper presents the alternative design of the shield block cooling path for a typical ITER blanket module with a predominantly sequential flow circuit. A number of serious disadvantages have been observed for the reference design, where the parallel flow circuit is used, which is inherent in the majority of blanket modules. The paper discusses these disadvantages and demonstrates the benefit of the alternative design based on the detailed design and the technological, hydraulic, thermal, structural and strength analyses, conducted for module no. 17

  20. Designing shields for KeV photons with genetic algorithms

    International Nuclear Information System (INIS)

    Asbury, Stephen; Holloway, James P.

    2011-01-01

    Shielding of x-ray sources and low energy gamma rays is often accomplished with lead aprons, comprising a thin layer (0.5 mm to 1 mm) of lead or similar high-Z material. In previous work the authors used Genetic Algorithms to explore the design of a shadow shield for space applications. Now those techniques have been applied to the problem of shielding humans from low energy gamma radiation. This paper uses a simple geometry to explore layering various materials as a method to reduce mass and dose for thin gamma shields. The genetic algorithms discover layers of materials with various Z is in fact more effective than an equivalent mass of Pb alone for lower energy gammas, but as the incident radiation energy increases the efficacy of such layering diminishes. The utility of varying Z for lower energy gammas is in part due to their complementary K-edges, where one material compensates for the transmission that would occur just below the K-edge in another material. (author)

  1. Tools and applications for core design and shielding in fast reactors

    International Nuclear Information System (INIS)

    Rachamin, Reuven

    2013-01-01

    Outline: • Modeling of SFR cores using the Serpent-DYN3D code sequence; • Core shielding assessment for the design of FASTEF-MYRRHA; • Neutron shielding studies on an advanced Molten Salt Fast Reactor (MSFR) design

  2. Shielding design for the front end of the CERN SPL.

    Science.gov (United States)

    Magistris, Matteo; Silari, Marco; Vincke, Helmut

    2005-01-01

    CERN is designing a 2.2-GeV Superconducting Proton Linac (SPL) with a beam power of 4 MW, to be used for the production of a neutrino superbeam. The SPL front end will initially accelerate 2 x 10(14) negative hydrogen ions per second up to an energy of 120 MeV. The FLUKA Monte Carlo code was employed for shielding design. The proposed shielding is a combined iron-concrete structure, which also takes into consideration the required RF wave-guide ducts and access labyrinths to the machine. Two beam-loss scenarios were investigated: (1) constant beam loss of 1 Wm(-1) over the whole accelerator length and (2) full beam loss occurring at various locations. A comparison with results based on simplified approaches is also presented.

  3. Shielding design of radioactive contaminated metal waste packaging

    International Nuclear Information System (INIS)

    Zou Wenhua; Dong Zhiqiang; Yao Zhenyu; Xu Shuhe; Wang Wen

    2015-01-01

    Focusing on the cylindrical source model to calculate γ dose field of waste packages with the relative formulae then derived. By comparing the calculated data of waste packages of type Ⅷ steel box with the monitoring data, it is found that the cylinder source model could accurately reflect the distributions of γ dose of the waste package. Based on the results of the cylindrical source model, a reasonable shielding technology applicable to waste package containers was designed to meet relevant requirements prescribed in standards about the transport and disposal of radioactive materials. The cylinder source model calculated dose distributions for single package in this paper is simple and easy to implement but slightly larger than the monitoring data providing a certain safety margin for the shielding design. It is suitable for radiological engineering practices. (authors)

  4. Monte Carlo based radial shield design of typical PWR reactor

    Energy Technology Data Exchange (ETDEWEB)

    Gul, Anas; Khan, Rustam; Qureshi, M. Ayub; Azeem, Muhammad Waqar; Raza, S.A. [Pakistan Institute of Engineering and Applied Sciences, Islamabad (Pakistan). Dept. of Nuclear Engineering; Stummer, Thomas [Technische Univ. Wien (Austria). Atominst.

    2017-04-15

    This paper presents the radiation shielding model of a typical PWR (CNPP-II) at Chashma, Pakistan. The model was developed using Monte Carlo N Particle code [2], equipped with ENDF/B-VI continuous energy cross section libraries. This model was applied to calculate the neutron and gamma flux and dose rates in the radial direction at core mid plane. The simulated results were compared with the reference results of Shanghai Nuclear Engineering Research and Design Institute (SNERDI).

  5. Preparation of a basic data base for shielding design. 4

    International Nuclear Information System (INIS)

    Nakao, Makoto; Takemura, Morio

    1999-03-01

    With use of a standard groupwise shielding design library JSSTDL produced from the latest evaluated nuclear data library JENDL-3.2, experimental analyses for the JASPER experiments were performed. In order to verify the new version of JSSTDL, whose cross sections of thermal energy region was updated, the polyethylene transmission experiments of the Special Materials Experiment was analysed again, and also zirconium transmission experiment of the Experiment was newly analysed. JSSTDL was applied to the analysis of neutron multiplicative region of the in-vessel fuel storage mockup configurations in the IVS Experiment. Also it was applied to the analyses of neutron streaming effect through the mockup of sodium window in B 4 C shield in the Flux Monitor Experiment and also the mockup of narrow gaps in thick concrete shield in the Gap streaming Experiment. The results were compared with those obtained by the same analysis method and input data using the JSDJ2 library that had been applied consistently to the JASPER experiment analyses. Although the analysis with the new version of JSSTDL resulted in a little reduction of overestimation in the polyethylene transmission configuration, the results obtained with JSSTDL are, in general, higher than those with JSDJ2 as had been found in analyses in preceding years for the Radial Shield Attenuation Experiment, the Axial Shield Experiment, the Intermediate Heat Exchanger Experiment and so on. Compilation of the input data necessary for future reanalyses of important configurations in JASPER experiments, that were selected at the first stage of this study, were continued and new data were added into the computer disk holding previously accumulated data. (author)

  6. Analysis, design, and constrution of a sacrificial shield wall

    International Nuclear Information System (INIS)

    Fialkow; Shah, S.B.

    1978-01-01

    The sacrificial shield wall, a cylindrical enclosure around the reactor pressure vessel (RPV), is a major component of nuclear power plants of the Boiling Water Reactor (BWR) type. A method developed for the analysis and design of such walls is described which eliminates shortcomings in methods used in current practice. The method treats the wall as a space frame of ring beams and columns and includes the skin plates as finite elements. Design loadings, load combinations, and acceptance criteria are presented. Results by this method are furnished and compared with results by an alternate method. Significant design features are described and a narrative of construction procedures is included. (Author)

  7. Impact of a flattening filter free linear accelerator on structural shielding design

    International Nuclear Information System (INIS)

    Jank, Julia; Kragl, Gabriele; Georg, Dietmar; Medical University of Vienna

    2014-01-01

    Purpose: The present study aimed to assess the effects of a flattening filter free medical accelerator on structural shielding demands of a treatment vault of a medical linear accelerator. We tried to answer the question, to what extent the required thickness of the shielding barriers can be reduced if instead of the standard flattened photon beams unflattened ones are used. Material and Methods: We chose both an experimental as well as a theoretical approach. On the one hand we measured photon dose rates at protected places outside the treatment room and compared the obtained results for flattened and unflattened beams. On the other hand we complied with international guidelines for adequate treatment vault design and calculated the shielding barriers according to the therein given specifications. Measurements were performed with an Elekta Precise trademark linac providing nominal photon energies of 6 and 10 MV. This machine underwent already earlier some modifications in order to be able to operate both with and without a flattening filter. Photon dose rates were measured with a LB133-1 dose rate meter manufactured by Berthold. To calculate the thickness of shielding barriers we referred to the Austrian standard OeNORM S 5216 and to the US American NCRP Report No. 151. Results: We determined a substantial photon dose rate reduction for all measurement points and photon energies. For unflattened 6 MV beams a reduction factor ranging from 1.4 to 1.8 was identified. The corresponding values for unflattened 10 MV beams were 2.1 and 3.2. The performed shielding calculations indicated the same tendency: For all relevant radiation components we found a reduction in shielding thickness when unflattened beams were used. The required thickness of primary barriers was reduced up to 8.0%, the thickness of secondary barriers up to 11.4%, respectively. Conclusions: For an adequate dimensioning of treatment vault shielding barriers it is by no means irrelevant if the

  8. Impact of a flattening filter free linear accelerator on structural shielding design.

    Science.gov (United States)

    Jank, Julia; Kragl, Gabriele; Georg, Dietmar

    2014-03-01

    The present study aimed to assess the effects of a flattening filter free medical accelerator on structural shielding demands of a treatment vault of a medical linear accelerator. We tried to answer the question, to what extent the required thickness of the shielding barriers can be reduced if instead of the standard flattened photon beams unflattened ones are used. We chose both an experimental as well as a theoretical approach. On the one hand we measured photon dose rates at protected places outside the treatment room and compared the obtained results for flattened and unflattened beams. On the other hand we complied with international guidelines for adequate treatment vault design and calculated the shielding barriers according to the therein given specifications. Measurements were performed with an Elekta Precise™ linac providing nominal photon energies of 6 and 10 MV. This machine underwent already earlier some modifications in order to be able to operate both with and without a flattening filter. Photon dose rates were measured with a LB133-1 dose rate meter manufactured by Berthold. To calculate the thickness of shielding barriers we referred to the Austrian standard ÖNORM S 5216 and to the US American NCRP Report No. 151. We determined a substantial photon dose rate reduction for all measurement points and photon energies. For unflattened 6 MV beams a reduction factor ranging from 1.4 to 1.8 was identified. The corresponding values for unflattened 10 MV beams were 2.1 and 3.2. The performed shielding calculations indicated the same tendency: For all relevant radiation components we found a reduction in shielding thickness when unflattened beams were used. The required thickness of primary barriers was reduced up to 8.0%, the thickness of secondary barriers up to 11.4%, respectively. For an adequate dimensioning of treatment vault shielding barriers it is by no means irrelevant if the accommodated linac operates with or without a flattening filter. The

  9. Impact of a flattening filter free linear accelerator on structural shielding design

    Energy Technology Data Exchange (ETDEWEB)

    Jank, Julia [Klinikum - Klagenfurt am Woerthersee (Austria). Inst. fuer Strahlentherapie und Radioonkologie; Kragl, Gabriele [Medical University of Vienna/AKH Vienna (Austria). Div. Medical Radiation Physics; Georg, Dietmar [Medical University of Vienna/AKH Vienna (Austria). Div. Medical Radiation Physics; Medical University of Vienna (Austria). Christian Doppler Lab. for Medical Radiation Research for Radiation Oncology

    2014-04-01

    Purpose: The present study aimed to assess the effects of a flattening filter free medical accelerator on structural shielding demands of a treatment vault of a medical linear accelerator. We tried to answer the question, to what extent the required thickness of the shielding barriers can be reduced if instead of the standard flattened photon beams unflattened ones are used. Material and Methods: We chose both an experimental as well as a theoretical approach. On the one hand we measured photon dose rates at protected places outside the treatment room and compared the obtained results for flattened and unflattened beams. On the other hand we complied with international guidelines for adequate treatment vault design and calculated the shielding barriers according to the therein given specifications. Measurements were performed with an Elekta Precise trademark linac providing nominal photon energies of 6 and 10 MV. This machine underwent already earlier some modifications in order to be able to operate both with and without a flattening filter. Photon dose rates were measured with a LB133-1 dose rate meter manufactured by Berthold. To calculate the thickness of shielding barriers we referred to the Austrian standard OeNORM S 5216 and to the US American NCRP Report No. 151. Results: We determined a substantial photon dose rate reduction for all measurement points and photon energies. For unflattened 6 MV beams a reduction factor ranging from 1.4 to 1.8 was identified. The corresponding values for unflattened 10 MV beams were 2.1 and 3.2. The performed shielding calculations indicated the same tendency: For all relevant radiation components we found a reduction in shielding thickness when unflattened beams were used. The required thickness of primary barriers was reduced up to 8.0%, the thickness of secondary barriers up to 11.4%, respectively. Conclusions: For an adequate dimensioning of treatment vault shielding barriers it is by no means irrelevant if the

  10. Preparation of a basic data base for shielding design. 3

    International Nuclear Information System (INIS)

    Takemura, Morio

    1998-03-01

    With use of a standard groupwise shielding design library JSSTDL produced from the latest evaluated nuclear data library JENDL-3.2, experimental analyses for the In-Vessel Fuel Storage (IVS) Experiment and the Intermediate Heat Exchanger (IHX) Experiment were performed. The results were compared with those obtained by the same analysis method and input data using the JSDJ2 library that had been applied consistently to the JASPER experiment analyses. In general, the results obtained with JSSTDL are higher than those with JSDJ2 as were found in analyses in last two years for the Radial Shield Attenuation Experiment and the Special Materials Experiment and also the Axial Shield Experiment. The calculation-to-experiment ratios of the fast neutron flux just behind deep penetration in sodium were obtained first by these IVS and IHX experimental analyses with the JSSTDL library. However, it was confirmed not to be easy to evaluate the accuracy of sodium cross section because of its dependency on how to model the swelled sodium slabs and tanks. The analyses with JSSTDL library were verified by comparison with other analyses with another library based on JENDL-3.2. Compilation of the input data necessary for future reanalyses of important configurations in JASPER experiments, that were selected at the first stage of this study, were continued and new data were added into the computer disk holding previously accumulated data. (author)

  11. Revise of a basic data base for shielding design

    International Nuclear Information System (INIS)

    Nakao, Makoto; Takemura, Morio

    2000-03-01

    With use of the two-dimensional discrete ordinates code DORT and the standard groupwise shielding design library JSSTDL produced from the latest evaluated nuclear data library JENDL-3.2, experimental analyses for the representative configurations in the Radial Shield Attenuation Experiment of the JASPER were performed. The results were compared with those obtained with use of traditional method DOT3.5/JSDJ2 for the previous JASPER experimental analyses. In general, the change of the cross section library gives higher results and the change of the transport code gives lower results. Finally the new analysis method gives better agreement with the experimental results and also less deviations of calculational errors between various detectors. Experimental analyses for the thick concrete configuration in the Gap Streaming Experiment of the JASPER was also performed with the new analysis method, after solving the poor agreement found in last year with the original JASPER experimental analyses. The same tendency due to the library change was confirmed with the above mentioned analyses of the Radial Shield Attenuation Experiment. Compilation of the input data necessary for future reanalyses of important configurations in JASPER experiments were continued through the above-mentioned experimental analyses and related informations were added for repletion of the database preserved in a computer disk holding previously accumulated data. Input data descriptions were made for auxiliary routines needed for the experimental analyses and their sample data were compiled and stored in the database. (author)

  12. Optimisation of structural shielding of accelerator control room for compliance with ALARA principle under Indian conditions

    International Nuclear Information System (INIS)

    Ahmad, Masood; Singh, Brijesh

    1999-01-01

    The case of a 20 MV x-ray accelerator has been considered in this paper for optimisation. An internationally recommended value of α = US$ 1000 per person-sievert has been assumed. Cost of concrete has been assumed as US$ 82.7/m 3 . It is seen that, extra shielding is needed to satisfy the ALARA principle. Further, the amount of requisite shielding increases with the degree of occupancy and, also, if the local construction materials or the labour are cheaper than considered in this paper. Accordingly 1.5 to 4.75 HVLs may be needed as extra shielding in different situations. Therefore, a site specific and installation specific optimisation of shielding is necessary

  13. Considerations on scattering and leak radiation for effective determination of secondary shielding in X-rays rooms of megavoltage

    International Nuclear Information System (INIS)

    Borges, Diogo da S.; Lava, Deise D.; Affonso, Renato R.W.; Moreira, Maria de L.; Guimaraes, Antonio C.F.

    2014-01-01

    This paper addresses the development of a algorithm capable of analyzing the thickness of the secondary shielding due to the production of secondary beams. The production of this beam requires consideration of scattering angle, as well as factors normally used for screening of medical facilities using radiographic techniques. Besides the beam emanated from scattering radiation, is is necessary to evaluate the contribution of leakage radiation, originating from equipment used for the production of the primary beam. A view of the mutual contribution of these radiation to the formation of the secondary beam has shown the need of using shieldings in adjacent walls of the room. The code was validated by comparison with an example case provided by NCRP-151 Report. In this report calculations for determining the secondary barrier for small angles are presented, that deserves greater attention for shielding and statements related to radiotherapy procedures of Modulated intensity. The results are consistent with those provided in the report, which makes the code can be used as a practical tool for the determination of effective shielding beams of megavoltage X-rays

  14. Shielding design of disposal container for disused sealed radioactive source

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Suk Hoon; Kim, Ju Youl [FNC Technology Co., Yongin (Korea, Republic of)

    2017-06-15

    Disused Sealed Radioactive Sources (DSRSs), which are stored temporally in the centralized storage facility of Korea Radioactive Waste Agency (KORAD), will be disposed of in the low- and intermediate-level radioactive waste disposal facility located in Wolsong. Accordingly, the future plan on DSRS disposal should be established as soon as possible in connection with the construction and operation plan of disposal facility. In this study, as part of developing the systematic management plan, the radiation shielding analysis for three types of disposal container was performed for all kinds of radionuclides (excluding mixed sources) contained in DSRSs generated from domestic area using MicroShield and MCNP5 codes in consideration of the preliminary post-closure safety assessment result for disposal options, source-specific characteristics, and etc. In accordance with the analysis result, thickness of inner container for general disposal container and dimensions (i.e. diameter and height) of inner capsule for two types of special disposal container were determined as 3 mm, OD40×H120 mm (for type 1), and OD100× H240 mm (for type 2), respectively. These values were reflected in the conceptual design of DSRS disposal container, and the structural integrity of each container was confrmed through the structural analysis carried out separately from this study. Given the shielding and structural analysis results, the conceptual design derived from this study sufficiently fulfills the technical standards in force and the design performance level. And consequently, it is judged that the safe management for DSRSs to be disposed of is achieved by utilizing the disposal container with the conceptual design devised.

  15. Shielding design of disposal container for disused sealed radioactive source

    International Nuclear Information System (INIS)

    Kim, Suk Hoon; Kim, Ju Youl

    2017-01-01

    Disused Sealed Radioactive Sources (DSRSs), which are stored temporally in the centralized storage facility of Korea Radioactive Waste Agency (KORAD), will be disposed of in the low- and intermediate-level radioactive waste disposal facility located in Wolsong. Accordingly, the future plan on DSRS disposal should be established as soon as possible in connection with the construction and operation plan of disposal facility. In this study, as part of developing the systematic management plan, the radiation shielding analysis for three types of disposal container was performed for all kinds of radionuclides (excluding mixed sources) contained in DSRSs generated from domestic area using MicroShield and MCNP5 codes in consideration of the preliminary post-closure safety assessment result for disposal options, source-specific characteristics, and etc. In accordance with the analysis result, thickness of inner container for general disposal container and dimensions (i.e. diameter and height) of inner capsule for two types of special disposal container were determined as 3 mm, OD40×H120 mm (for type 1), and OD100× H240 mm (for type 2), respectively. These values were reflected in the conceptual design of DSRS disposal container, and the structural integrity of each container was confrmed through the structural analysis carried out separately from this study. Given the shielding and structural analysis results, the conceptual design derived from this study sufficiently fulfills the technical standards in force and the design performance level. And consequently, it is judged that the safe management for DSRSs to be disposed of is achieved by utilizing the disposal container with the conceptual design devised

  16. License Application Design Selection Feature Report: Waste Package Self Shielding Design Feature 13

    International Nuclear Information System (INIS)

    Tang, J.S.

    2000-01-01

    In the Viability Assessment (VA) reference design, handling of waste packages (WPs) in the emplacement drifts is performed remotely, and human access to the drifts is precluded when WPs are present. This report will investigate the feasibility of using a self-shielded WP design to reduce the radiation levels in the emplacement drifts to a point that, when coupled with ventilation, will create an acceptable environment for human access. This provides the benefit of allowing human entry to emplacement drifts to perform maintenance on ground support and instrumentation, and carry out performance confirmation activities. More direct human control of WP handling and emplacement operations would also be possible. However, these potential benefits must be weighed against the cost of implementation, and potential impacts on pre- and post-closure performance of the repository and WPs. The first section of this report will provide background information on previous investigations of the self-shielded WP design feature, summarize the objective and scope of this document, and provide quality assurance and software information. A shielding performance and cost study that includes several candidate shield materials will then be performed in the subsequent section to allow selection of two self-shielded WP design options for further evaluation. Finally, the remaining sections will evaluate the impacts of the two WP self-shielding options on the repository design, operations, safety, cost, and long-term performance of the WPs with respect to the VA reference design

  17. An analytical solution to the shielding of Co 60 teletherapy rooms based on a semiempirical equation of photon attenuation

    International Nuclear Information System (INIS)

    Saez, D.G.; Hernandez, L.; Borroto, M.; Figueredo, M.

    1996-01-01

    A semiempirical equation of polynomial-exponential type is presented to describe the transmission data of Co-60 gamma radiation in finite materials of concrete and lead. This equation and the expression obtained for the relationship of scatter-to-incident exposure made easy the developing in computer of an analytical solution for shielding calculations of Co 60 teletherapy rooms, based on the procedures of the NCRP 49 and Simpkin's method. The standard error in the estimation of parameters is less than 1.7 % except for the attenuation of 150 'o' scattered radiation in concrete that resulted in 6.3 % for one of them. The shielding calculations were compared with the data in NCRP 49 for the same conditions with a correlation better than 99 %

  18. Design and Testing of Improved Spacesuit Shielding Components

    International Nuclear Information System (INIS)

    Ware, J.; Ferl, J.; Wilson, J.W.; Clowdsley, M.S.; DeAngelis, G.; Tweed, J.; Zeitlin, C.J.

    2002-01-01

    In prior studies of the current Shuttle Spacesuit (SSA), where basic fabric lay-ups were tested for shielding capabilities, it was found that the fabric portions of the suit give far less protection than previously estimated due to porosity and non-uniformity of fabric and LCVG components. In addition, overall material transmission properties were less than optimum. A number of alternate approaches are being tested to provide more uniform coverage and to use more efficient materials. We will discuss in this paper, recent testing of new material lay-ups/configurations for possible use in future spacesuit designs

  19. Preliminary shielding design evaluation for reactor assembly of SMART

    International Nuclear Information System (INIS)

    Kim, Kyo Youn; Kang, Chang M.; Kim, Ha Yong; Zee, Sung Quun; Chang, Moon Hee

    1999-03-01

    This report describes a preliminary evaluations of SMART shielding design near the reactor core by using the DORT two-dimensional discrete ordinates transport code. The results indicate that maximum neutron fluence at the bottom of reactor vessel is 1.64x10 17 n/cm 2 and that on the radial surface of reactor vessel is 6.71x10 16 n/cm 2 . These results meet the requirement, 1.0x10 20 n/cm 2 , in 10 CFR 50.61 and the integrity of SMART reactor vessel is confirmed during the lifetime of reactor. (Author). 20 refs., 11 tabs., 8 figs

  20. Shield design for the Fusion Materials Irradiation Test facility

    International Nuclear Information System (INIS)

    Carter, L.L.; Mann, F.M.; Morford, R.J.; Wilcox, A.D.; Johnson, D.L.; Huang, S.T.

    1983-03-01

    The shield design for the Fusion Materials Irradiation Test facility is based upon one-, two- and three-dimensional transport calculations with experimental measurements utilized to refine the nuclear data including the neutron cross sections from 20 to 50 MeV and the gamma ray and neutron source terms. The high energy neutrons and deuterons produce activation products from the numerous reactions that are kinematically allowed. The analyses for both beam-on and beam-off (from the activation products) conditions have required extensive nuclear data libraries and the utilization of Monte Carlo, discrete ordinates, point kernel and auxiliary computer codes

  1. Guidelines for control room systems design. Working material. Report

    International Nuclear Information System (INIS)

    1993-01-01

    This report contains comprehensive technical and methodological information and recommendations for the benefit of Member States for advice and assistance in ''NPP control room systems'' design backfitting existing nuclear power plants and design for future stations. The term ''Control Room Systems'' refers to the entire human/machine interface for the nuclear stations - including the main control room, back-ups control room and the emergency control rooms, local panels, technical support centres, operating staff, operating procedures, operating training programs, communications, etc. Refs, figs and tabs

  2. Magnetic Materials Characterization and Modeling for the Enhanced Design of Magnetic Shielding of Cryomodules in Particle Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Sah, Sanjay [Virginia Commonwealth Univ., Richmond, VA (United States)

    2016-05-31

    Particle accelerators produce beams of high-energy particles, which are used for both fundamental and applied scientific research and are critical to the development of accelerator driven sub-critical reactor systems. An effective magnetic shield is very important to achieve higher quality factor (Qo) of the cryomodule of a particle accelerator. The allowed value of field inside the cavity due to all external fields (particularly the Earth’s magnetic field) is ~15 mG or less. The goal of this PhD dissertation is to comprehensively study the magnetic properties of commonly used magnetic shielding materials at both cryogenic and room temperatures. This knowledge can be used for the enhanced design of magnetic shields of cryomodes (CM) in particle accelerators. To this end, we first studied the temperature dependent magnetization behavior (M-H curves) of Amumetal and A4K under different annealing and deformation conditions. This characterized the effect of stress or deformation induced during the manufacturing processes and subsequent restoration of high permeability with appropriate heat treatment. Next, an energy based stochastic model for temperature dependent anhysteretic magnetization behavior of ferromagnetic materials was proposed and benchmarked against experimental data. We show that this model is able to simulate and explain the magnetic behavior of as rolled, deformed and annealed amumetal and A4K over a large range of temperatures. The experimental results for permeability are then used in a finite element model (FEM) in COMSOL to evaluate the shielding effectiveness of multiple shield designs at room temperature as well as cryogenic temperature. This work could serve as a guideline for future design, development and fabrication of magnetic shields of CMs.

  3. SP-100 GES/NAT radiation shielding systems design and development testing

    International Nuclear Information System (INIS)

    Disney, R.K.; Kulikowski, H.D.; McGinnis, C.A.; Reese, J.C.; Thomas, K.; Wiltshire, F.

    1991-01-01

    Advanced Energy Systems (AES) of Westinghouse Electric Corporation is under subcontract to the General Electric Company to supply nuclear radiation shielding components for the SP-100 Ground Engineering System (GES) Nuclear Assembly Test to be conducted at Westinghouse Hanford Company at Richland, Washington. The radiation shielding components are integral to the Nuclear Assembly Test (NAT) assembly and include prototypic and non-prototypic radiation shielding components which provide prototypic test conditions for the SP-100 reactor subsystem and reactor control subsystem components during the GES/NAT operations. W-AES is designing three radiation shield components for the NAT assembly; a prototypic Generic Flight System (GFS) shield, the Lower Internal Facility Shield (LIFS), and the Upper Internal Facility Shield (UIFS). This paper describes the design approach and development testing to support the design, fabrication, and assembly of these three shield components for use within the vacuum vessel of the GES/NAT. The GES/NAT shields must be designed to operate in a high vacuum which simulates space operations. The GFS shield and LIFS must provide prototypic radiation/thermal environments and mechanical interfaces for reactor system components. The NAT shields, in combination with the test facility shielding, must provide adequate radiation attenuation for overall test operations. Special design considerations account for the ground test facility effects on the prototypic GFS shield. Validation of the GFS shield design and performance will be based on detailed Monte Carlo analyses and developmental testing of design features. Full scale prototype testing of the shield subsystems is not planned

  4. A study on optimization of photoneutron shielding in a medical accelerator room by using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Kim, Yong Nam; Jeong, Kyoungkeun; Kim, Joo Young; Lee, Chang Geol; Seong, Jinsil; Choi, Sang Hyun; Kim, Chan Hyeong

    2008-01-01

    Medical linear accelerators operating above 10 MV require door shielding for neutrons in addition to photons. A criterion for choice of optimal configuration of lamination of BPE (Borated Polyethylene) and lead is not clear. Moreover, optimal configuration cannot be determined by the conventional method using an analytical formula and simple measurement. This study performs Monte Carlo simulation of radiation field in a commercial LINAC room with 15 MV X-ray sources. Considering two configuration of lamination such as 'lead-BPE' and 'lead-BPE-lead', dose equivalents are calculated by using the MCNPX code and comparative analyses are performed with each other. The obtained results show that there is no significant difference in neuron shielding between both configurations, whereas lead-BPE-lead is more effective for photon shielding. It is also noted that the absolute values of neutron doses are much greater than that of photon doses outside as well as inside the door, by three orders of magnitude. As a conclusion, the laminating of lead-BPE is suggested as the optimal configuration from the viewpoint of simplicity in fabrication and handling, even though it has no significant difference from lead-BPE-lead in terms of total dose equivalent. (author)

  5. Design of Reflective, Photonic Shields for Atmospheric Reentry

    Science.gov (United States)

    Komarevskiy, Nikolay; Shklover, Valery; Braginsky, Leonid; Hafner, Christian; Fabrichnaya, Olga; White, Susan; Lawson, John

    2010-01-01

    We present the design of one-dimensional photonic crystal structures, which can be used as omnidirectional reflecting shields against radiative heating of space vehicles entering the Earth's atmosphere. This radiation is approximated by two broad bands centered at visible and near-infrared energies. We applied two approaches to find structures with the best omnidirectional reflecting performance. The first approach is based on a band gap analysis and leads to structures composed of stacked Bragg mirrors. In the second approach, we optimize the structure using an evolutionary strategy. The suggested structures are compared with a simple design of two stacked Bragg mirrors. Choice of the constituent materials for the layers as well as the influence of interlayer diffusion at high temperatures are discussed.

  6. A Combined Shielding Design for a Neutron Generator and a Linear Accelerator at Soreq NRC

    International Nuclear Information System (INIS)

    Epstein, L.

    2014-01-01

    A new radiography facility is designed at Soreq NRC. The facility will hold a neutron generator that produces 1.73·109 n/s with an energy of 14 MeV and a linear accelerator that accelerates electrons to an energy of 9 MeV. The two radiation sources will be installed in 2 separate laboratories that will be built in an existing building. Each laboratory will have its own machine and control room. The dose rates around the sources were calculated using the FLUKA Monte Carlo code(1,2). The annual doses were calculated in several regions around the generator and the accelerator laboratories in accordance with the occupancy in each area. The calculated annual doses were compared with the dose limits specified in the Safety at Work Regulations(3) and the IAEC Standard for Protection against Ionizing Radiation. The shielding was designed to comply with the following dose constraints: 0.3 mSv/y for members of the public and 2 mSv/y for radiation workers. Each radiation source is planned to produce radiation for a maximum of 500 hours per year. The dose rate in the direct beam of the accelerator is 30 Gy/min at 1 m from the source and it will be surrounded by a collimator with an opening of 30N-tilde horizontally and 2 mm vertically, 3 m from the radiation source. The leakage radiation dose will not be greater than 1.5 mGy/min (0.005% of the direct beam, according to the manufacturer). The leakage radiation will be produced isotropically. The neutron generator will be surrounded by a shielding made of a 10 cm iron cylinder (density 7.87 g/cm3), surrounded by 50 cm of borated polyethylene (atomic percent: H (13.8%), C (82.2%), B (4%), density: 0.92 g/cm3) and 5 cm of lead (density 11.35 g/cm3). The neutron generator shielding was not designed or required in the present shielding design but was considered in the shielding calculations

  7. OPAL shield design performance assessment. Comparison of measured dose rates against the corresponding design calculated values. A designer perspective

    Energy Technology Data Exchange (ETDEWEB)

    Brizuela, Martin; Albornoz, Felipe [INVAP SE, Av. Cmte. Piedrabuena, Bariloche (Argentina)

    2012-03-15

    A comparison of OPAL shielding calculations against measurements carried out during Commissioning, is presented for relevant structures such as the reactor block, primary shutters, neutron guide bunker, etc. All the results obtained agree very well with the measured values and contribute to establish the confidence on the calculation tools (MCNP4, DORT, etc.) and methodology used for shielding design. (author)

  8. Design and Performance of a Metal-Shielded Piezoelectric Sensor.

    Science.gov (United States)

    Sáenz de Inestrillas, Álvaro; Camarena, Francisco; Bou Cabo, Manuel; Barreiro, Julián M; Reig, Antonio

    2017-06-04

    In certain circumstances when acoustic measurements are required in the presence of explosive atmospheres the sensor must be placed inside a Faraday Cage. Piezoelectric active materials are suitable for this purpose as they do not need an electrical power supply, although the metal shielding can considerably reduce sensor sensitivity, which is already low at the acoustic frequency range (<20 kHz). This paper describes a metal-shielded piezoelectric sensor designed to work in the range of frequencies between 1 and 2 kHz and in these environmental conditions. The main idea was to add a thin material layer to the front face of the piezoelectric ceramic in order to force the system to vibrate in flexure mode at low frequencies. The resonant frequency and sensitivity of the system was studied as a function of the radius, thickness, and material of the thin layer. The study includes a comparison of theoretical model, FEM simulation, and real data measured using three aluminum and three steel prototypes of different sizes.

  9. Design and Performance of a Metal-Shielded Piezoelectric Sensor

    Directory of Open Access Journals (Sweden)

    Álvaro Sáenz de Inestrillas

    2017-06-01

    Full Text Available In certain circumstances when acoustic measurements are required in the presence of explosive atmospheres the sensor must be placed inside a Faraday Cage. Piezoelectric active materials are suitable for this purpose as they do not need an electrical power supply, although the metal shielding can considerably reduce sensor sensitivity, which is already low at the acoustic frequency range (<20 kHz. This paper describes a metal-shielded piezoelectric sensor designed to work in the range of frequencies between 1 and 2 kHz and in these environmental conditions. The main idea was to add a thin material layer to the front face of the piezoelectric ceramic in order to force the system to vibrate in flexure mode at low frequencies. The resonant frequency and sensitivity of the system was studied as a function of the radius, thickness, and material of the thin layer. The study includes a comparison of theoretical model, FEM simulation, and real data measured using three aluminum and three steel prototypes of different sizes.

  10. Re-evaluation of the shielding adequacy of the brachytherapy treatment room at Korle-Bu teaching hospital, Ghana

    International Nuclear Information System (INIS)

    Arwui, C. C.

    2009-06-01

    Staff and the general public's safety during the operation of the 137 Cs brachytherapy unit at the Korle Bu teaching hospital depends on the adequacy of the shielding of the facility. Shielding design of the brachytherapy unit at the hospital was based on postulated workload and postulated occupancy factors to critical locations at the facility where the public and staff may occupy. This facility has been in existence for the past twelve (12) years and has accumulated operational workload data which differs from the postulated one. A study was carried out to re-evaluate the integrity of the biological shielding of the 137 Cs brachytherapy unit. This study analyzed the accumulated workload data and used the information to perform shielding calculations to verify the adequacy of the biological shielding thicknesses to provide sufficient protection of staff and the public. Dose rate calculations were verified by measurements with calibrated dose rate meters. This provided the basis for determining the current state of protection and safety for staff and the general public. The results show that despite the variation in actual and postulated workloads, the dose rates were below the reference values of 0.5μSv/h for public areas and 7.5μSv/h for controlled areas. It was confirmed that the present shielding thickness of 535 mm can accommodate a high dose rate (HDR) 192 Ir source with activity in the range 370 - 570 GBq with an operational workload of 30 patients per week and an average treatment time of 10 minutes.

  11. Control room philosophy: Principles of control room design and control room work; Kontrollrumsfilosofi: Principer foer kontrollrumsutformning och kontrollrumsarbete

    Energy Technology Data Exchange (ETDEWEB)

    Skriver, Jan; Ramberg, Jasmine; Allwin, Pernilla [Scandpower Risk Management AB, Uppsala (Sweden)

    2006-01-15

    In order to provide insights for improvement of work in control rooms several factors have to be considered. Knowledge of principles including control room philosophies will guide the recommended improvements. In addition to knowledge about specific principles an advantage for an organization can be an understanding of similarities and policies used in other high risk industry. The report has been developed on the basis of a document analysis of international standards and other guiding documents. (NUREG 0711, ISO 11064, ISO 6385, IEC 60964). In addition to the document analysis which has strived to compare the documents to see similarities in important principals, experience from working with control room design, modifications and evaluations in other high risk industries has pervaded the report. Important principles have been identified which are recommended to be included in a control room philosophy. Many of these are similar to the principles identified in the international standards. An additional principal which is regarded as important is the utilization of Key Performance Indicators (KPI) which can be used as a measure to target preventative means. Further more it is critical that the control room philosophy is easy to access and comprehend for all users. One of the challenges that remain after having developed a control room philosophy is how to utilize it in the daily work situation. It is vital that the document remains as a living document, guiding the continual improvement of the control room in the various life cycle stages.

  12. Radiological Shielding Design for the Neutron High-Resolution Backscattering Spectrometer EMU at the OPAL Reactor

    Directory of Open Access Journals (Sweden)

    Ersez Tunay

    2017-01-01

    Full Text Available The shielding for the neutron high-resolution backscattering spectrometer (EMU located at the OPAL reactor (ANSTO was designed using the Monte Carlo code MCNP 5-1.60. The proposed shielding design has produced compact shielding assemblies, such as the neutron pre-monochromator bunker with sliding cylindrical block shields to accommodate a range of neutron take-off angles, and in the experimental area - shielding of neutron focusing guides, choppers, flight tube, backscattering monochromator, and additional shielding elements inside the Scattering Tank. These shielding assemblies meet safety and engineering requirements and cost constraints. The neutron dose rates around the EMU instrument were reduced to < 0.5 µSv/h and the gamma dose rates to a safe working level of ≤ 3 µSv/h.

  13. Radiological Shielding Design for the Neutron High-Resolution Backscattering Spectrometer EMU at the OPAL Reactor

    Science.gov (United States)

    Ersez, Tunay; Esposto, Fernando; Souza, Nicolas R. de

    2017-09-01

    The shielding for the neutron high-resolution backscattering spectrometer (EMU) located at the OPAL reactor (ANSTO) was designed using the Monte Carlo code MCNP 5-1.60. The proposed shielding design has produced compact shielding assemblies, such as the neutron pre-monochromator bunker with sliding cylindrical block shields to accommodate a range of neutron take-off angles, and in the experimental area - shielding of neutron focusing guides, choppers, flight tube, backscattering monochromator, and additional shielding elements inside the Scattering Tank. These shielding assemblies meet safety and engineering requirements and cost constraints. The neutron dose rates around the EMU instrument were reduced to < 0.5 µSv/h and the gamma dose rates to a safe working level of ≤ 3 µSv/h.

  14. A User's Manual for the NRN Shield Design Method

    Energy Technology Data Exchange (ETDEWEB)

    Hjaerne, Leif [ed.; Aalto, E; Fraeki, R; Leimdoerfer, M; Lindblom, K; Linde, S; Malen, K; Nyman, K

    1964-06-15

    This report describes a code system for bulk shield design written for a Ferranti Mercury computer and is intended as a manual for those using the programme. The idea of an 'almost direct' flux, as in the removal theory serves as a basis for further development of the theory. An important aspiration has been to minimize the manual work of administering the codes. The codes concerned are: NECO, computing necessary group constants from primary data, REFUSE and REBOX (infinite plane or cylindrical, and box geometry, respectively), computing removal flux, NEDI a one-dimensional (plane, spherical, cylindrical) diffusion multigroup code, and SALOME a Monte Carlo code computing the gamma flux. Output tapes are constructed for direct use as input tapes, when required, for a following code.

  15. A User's Manual for the NRN Shield Design Method

    International Nuclear Information System (INIS)

    Hjaerne, Leif; Aalto, E.; Fraeki, R.; Leimdoerfer, M.; Lindblom, K.; Linde, S.; Malen, K.; Nyman, K.

    1964-06-01

    This report describes a code system for bulk shield design written for a Ferranti Mercury computer and is intended as a manual for those using the programme. The idea of an 'almost direct' flux, as in the removal theory serves as a basis for further development of the theory. An important aspiration has been to minimize the manual work of administering the codes. The codes concerned are: NECO, computing necessary group constants from primary data, REFUSE and REBOX (infinite plane or cylindrical, and box geometry, respectively), computing removal flux, NEDI a one-dimensional (plane, spherical, cylindrical) diffusion multigroup code, and SALOME a Monte Carlo code computing the gamma flux. Output tapes are constructed for direct use as input tapes, when required, for a following code

  16. The New Anechoic Shielded Chambers Designed for Space and Commercial Applications at LIT

    Science.gov (United States)

    da Silva, Benjamim; Galvao, M. C.; Pereira, Clovis Solano

    2008-01-01

    The main objective of this paper is to present the capabilities of the new anechoic shielded rooms designed for space and commercial applications as part of the Integration and Testing Laboratory (LIT, Laboratorio de Integracao e Testes) in Brazil. A new anechoic shielded room named CBA2 has been in full operation since March 2007 and a remodeled chamber CBA1 is planned to be ready by the end of 2008, replacing an old facility which was in operation for the last 18 years. The Brazilian Space Program started with very small and simple satellites and the old CBA1 chamber was conceived in 1987 to accomplish the EMI/EMC tests not requiring significant volumes. Since the very beginning this facility was also used by the private sector for other applications mainly due to the absorption of digital electronics in all kind of products. The intense use of this facility during the last years, operating three shifts a day, caused a normal degradation and imposed several limitations. Therefore, a new totally remodeled chamber was designed considering the state of the art in terms of absorbers and associated instrumentation. On the other hand the facility CBA2 was conceived, designed and implemented to test large satellites taking into account the advance of the technology in terms of RF frequencies, power level, testing methodologies and several other factors. A very interesting and unique aspect of this project was the partnership between the private sector and governmental institution. As a result, the total investment was shared between several companies and consequently a time-sharing use of the facility as well.

  17. The investigation of the design of hybrid operating room

    International Nuclear Information System (INIS)

    Jiang Weihao; Li Jun

    2011-01-01

    Objective: To investigate the design of the interventional operating room that can meet the needs of modern DSA operation, and the overall arrangement of the hybrid operating room should be reasonable, practical and perspective. Methods: The experience and understanding obtained from the designing and planning of the new Building of Radiology and Surgery in authors' hospital were summarized. In order to meet the requirements of aseptic surgical practices and a full-featured hybrid operating room the following factors should be carefully and synthetically taken into account: the room size, the functional sub-areas, the operational procedures, the aseptic specification, etc. Results: The sufficient verification and scientific design were the important link for building a hybrid operating room. It could provide the surgeons and interventional physicians with more alternative operating methods and it could represent the development trend of medical technology. Conclusion: When planning and designing a new DSA operating room, various factors related to the interventional procedures, such as the room size, the functional sub-areas, the operational procedures and the aseptic specification, should be carefully and synthetically taken into account. The standard of aseptic procedure must be strictly complied with and the various functional sub-areas need to be rationally distributed. The design of hybrid operating room, which joins the functions of both open surgery and interventional management together, should be scientific, practical and perspective. (authors)

  18. Status of the ITER tokamak nuclear shielding and radiological protection design

    Energy Technology Data Exchange (ETDEWEB)

    Leichtle, D., E-mail: dieter.leichtle@f4e.europa.eu [Fusion for Energy, Josep Pla 2, Barcelona 08019 (Spain); Chaffard, P.Y.; Izquierdo, J. [Fusion for Energy, Josep Pla 2, Barcelona 08019 (Spain); Juarez, R. [UNED, Juan del Rosal 12, Madrid 28040 (Spain); Pampin, R.; Portone, A. [Fusion for Energy, Josep Pla 2, Barcelona 08019 (Spain)

    2016-11-01

    Highlights: • Comprehensive review of design status of the ITER tokamak regarding nuclear shielding. • Investigation of shield design options and streaming mitigation measures. • Review of state-of-the-art shutdown dose rate analyses for selected port systems. - Abstract: Nuclear shielding of the ITER tokamak encompasses several systems and interfaces in a complex radiation environment. Therefore any shielding design has to involve a series of structures, systems and components in an integrated approach. This is evident for the complex ex-vessel radiation environment with streaming and leakage of plasma neutrons and subsequent activation of ex-vessel structures which give raise to excessive shutdown dose rates in accessible areas of the cryostat. The paper reviews recent nuclear analyses related to the performance of primary shields and highlights challenges toward an integrated nuclear shielding design. The general need of propagation of shielding requirements is highlighted in the context of radiation cross talk due to penetrations. Radiation streaming through gaps and penetrations is a key problem in any efficient shield design. The impact on the evolving radiation environment due to several design options along streaming paths such as port gaps, as well as their modeling for nuclear analysis, is presented. Implications regarding design integration and compliance with integrated shielding requirements and ALARA dose are finally given.

  19. Responsibilities for control room design in the USA

    International Nuclear Information System (INIS)

    Leary, J.E.; Barnhart, C.G.

    1980-01-01

    In the design and construction of nuclear power plants in the United States, the architect-engineering firm usually serves as the principal co-ordinator for the various parties involved. Recent events such as the Three Mile Island accident have focused attention on operability and human factors engineering in the design of the control room. This article describes current trends in control room design and the division of responsibility between the plant owner, the reactor vendor, and the architect-engineer. (author)

  20. Neutron beam-line shield design for the protein crystallography instrument at the Lujan Center

    International Nuclear Information System (INIS)

    Russell, G.J.; Pitcher, E.J.; Muhrer, G.; Ferguson, P.D.

    2001-01-01

    We have developed a very useful methodology for calculating absolute total (neutron plus gamma-ray) dose equivalent rates for use in the design of neutron beam line shields at a spallation neutron source. We have applied this technique to the design of beam line shields for several new materials science instruments being built at the Manuel Lujan Jr. Neutron Scattering Center. These instruments have a variety of collimation systems and different beam line shielding issues. We show here some specific beam line shield designs for the Protein Crystallography Instrument. (author)

  1. Design and shielding calculation for a PET/CT facility

    International Nuclear Information System (INIS)

    Martin Escuela, J. M.; Palau San Pedro, A.; Lopez Diaz, A.

    2013-01-01

    Following the AAPM Task Group Report No. 108, the NCRP Report No. 147 recommendations and the Cuban's local regulations for nuclear medicine practice were carried out the safety planning and design of a new PET/CT facility for the Nuclear Medicine Department of 'Hermanos Ameijeiras' Hospital. It should be installed in the top floor of the NM building (3th floor), occupied by offices, classrooms and ancillaries areas, meanwhile in the second floor is working the conventional nuclear medicine department. The radiation doses were evaluated in areas of the second, third and quarter floor taking into account the pet isotope, the workload, the occupancy factors of each place, the use factors of different sources and the dose reduction factors, warranty the accomplish of the Cuban dose restrictions associated to the nuclear medicine practice. In each point of calculation was considered the contribution from each source to the total dose, as well as the contribution of the CT in the adjacent room to the imaging room. For the proper facility design was considered the transmission factors of the existing barriers, and calculated the new ones to be added between each source and the estimation point, keeping in mind the space limitations. The PET/CT design plan meet all the needs, the development of the project is consistent with the mission of the facility and the radiation protection regulations of nuclear medicine. (Author)

  2. An optimizing design method for a compact iron shielded superconducting magnet for use in MRI

    International Nuclear Information System (INIS)

    Tang Xin; Zu Donglin; Wang Tao; Han Baohui

    2010-01-01

    A method is developed for designing a special iron shielded superconducting magnet for MRI in this paper. The shield is designed as an integral part of the cryostat and high permeability and high saturated magnetization iron material is adopted. This scheme will result in a compact iron shielded magnet. In the presented design, the finite element (FE) method is adopted to calculate the magnetic field produced by superconducting coils and nonlinear iron material. The FE method is incorporated into the simulated annealing method which is employed for corresponding optimization. Therefore, geometrical configurations of both coils and iron shield can be optimized together. This method can deal with discrete design variables which are defined to describe the cable arrangements of coil cross sections. A detailed algorithm of the present design is described and an example for designing a 1.5 T clinical iron shielded magnet for MRI is shown.

  3. Simbol-X Mirror Module Thermal Shields: I-Design and X-Ray Transmission

    Science.gov (United States)

    Collura, A.; Barbera, M.; Varisco, S.; Basso, S.; Pareschi, G.; Tagliaferri, G.; Ayers, T.

    2009-05-01

    The Simbol-X mission is designed to fly in formation flight configuration. As a consequence, the telescope has both ends open to space, and thermal shielding at telescope entrance and exit is required to maintain temperature uniformity throughout the mirrors. Both mesh and meshless solutions are presently under study for the shields. We discuss the design and the X-ray transmission.

  4. Simbol-X Mirror Module Thermal Shields: I - Design and X-Ray Transmission

    International Nuclear Information System (INIS)

    Collura, A.; Varisco, S.; Barbera, M.; Basso, S.; Pareschi, G.; Tagliaferri, G.; Ayers, T.

    2009-01-01

    The Simbol-X mission is designed to fly in formation flight configuration. As a consequence, the telescope has both ends open to space, and thermal shielding at telescope entrance and exit is required to maintain temperature uniformity throughout the mirrors. Both mesh and meshless solutions are presently under study for the shields. We discuss the design and the X-ray transmission.

  5. Taking account of human factors in control-room design

    International Nuclear Information System (INIS)

    Dien, Y.; Montmayeul, R.

    1995-07-01

    Since the Three Mile Island accident two ways for improving the Human-Machine Interface have mainly been followed: the development of computerized operator aids in existing control-rooms and the design of advanced control-rooms. Insufficient attention paid to human factors in the design of operator aids has generally led to these aids being neglected or unused by their potential users. While for the design of advanced control-rooms efforts have been made for dealing with human factors in more extensive way. Based upon this experience, a general method for taking account of human factors in a control-room design has been devised and is described in this paper. (author)

  6. Human factors methods for nuclear control room design. Volume 2. Human factors survey of control room design practices

    International Nuclear Information System (INIS)

    Seminara, J.L.; Parsons, S.O.

    1979-11-01

    An earlier review of the control rooms of operating nuclear power plants identified many design problems having potential for degrading operator performance. As a result, the formal application of human factors principles was found to be needed. This report demonstrates the use of human factors in the design of power plant control rooms. The approaches shown in the report can be applied to operating power plants, as well as to those in the design stage. This study documents human factors techniques required to provide a sustained concern for the man-machine interface from control room concept definition to system implementation

  7. Shield design for next-generation, low-neutron-fluence, superconducting tokamaks

    International Nuclear Information System (INIS)

    Lee, V.D.; Gohar, Y.

    1985-01-01

    A shield design using stainless steel (SST), water, boron carbide, lead, and concrete materials was developed for the next-generation tokamak device with superconducting toroidal field (TF) coils and low neutron fluence. A device such as the Tokamak Fusion Core Experiment (TFCX) is representative of the tokamak design which could use this shield design. The unique feature of this reference design is that a majority of the bulk steel in the shield is in the form of spherical balls with two small, flat spots. The balls are purchased from ball-bearing manufacturers and are added as bulk shielding to the void areas of builtup, structural steel shells which form the torus cavity of the plasma chamber. This paper describes the design configuration of the shielding components

  8. Shield design for next-generation, low-neutron-fluence, superconducting tokamaks

    International Nuclear Information System (INIS)

    Lee, V.D.; Gohar, Y.

    1985-01-01

    A shield design using stainless steel (SST), water, boron carbide, lead, and concrete materials was developed for the next-generation tokamak device with superconducting toroidal field (TF) coils and low neutron fluence. A device such as the Tokamak Fusion Core Experiment (TFCX) is representative of the tokamak design which could use this shield design. The unique feature of this reference design is that a majority of the bulk steel in the shield is in the form of spherical balls with two small, flat spots. The balls are purchased from ball-bearing manufacturers and are added as bulk shielding to the void areas of built-up, structural steel shells which form the torus cavity of the plasma chamber. This paper describes the design configuration of the shielding components

  9. Monte Carlo based radial shield design of typical PWR reactor

    Energy Technology Data Exchange (ETDEWEB)

    Gul, Anas; Khan, Rustam; Qureshi, M. Ayub; Azeem, Muhammad Waqar; Raza, S.A. [Pakistan Institute of Engineering and Applied Sciences, Islamabad (Pakistan). Dept. of Nuclear Engineering; Stummer, Thomas [Technische Univ. Wien (Austria). Atominst.

    2016-11-15

    Neutron and gamma flux and dose equivalent rate distribution are analysed in radial and shields of a typical PWR type reactor based on the Monte Carlo radiation transport computer code MCNP5. The ENDF/B-VI continuous energy cross-section library has been employed for the criticality and shielding analysis. The computed results are in good agreement with the reference results (maximum difference is less than 56 %). It implies that MCNP5 a good tool for accurate prediction of neutron and gamma flux and dose rates in radial shield around the core of PWR type reactors.

  10. Design of a multisystem remote maintenance control room

    International Nuclear Information System (INIS)

    Draper, J.V.; Handel, S.J.; Kring, C.T.; Kawatsuma, S.

    1988-01-01

    The Remote Systems Development Section of the Consolidated Fuel Reprocessing Program at the Oak Ridge National Laboratory (ORNL) and Japan's Power Reactor and Nuclear Fuel Development Corporation (PNC) recently collaborated in the development of a control room concept for remote operations. This report describes design methods and the resulting control room concept. The design project included five stages. The first was compilation of a complete function list; functions are tasks performed by operators in the control room while operating equipment located in the remote area. The second step was organization of the function list into ''function groups;'' function groups are sets of functions that operate one piece of equipment. The third stage was determination of crew size and requirements for supervision. The fourth stage was development of conceptual designs of displays and controls. The fifth stage was development of plans for placement of crew stations within the control room. 5 figs., 1 tab

  11. Radiation protection/shield design: a need for a systems approach

    International Nuclear Information System (INIS)

    Disney, R.K.

    1977-01-01

    Radiation protection/shielding design of a nuclear facility requires a coordinated effort of many engineering disciplines to meet the requirements imposed by regulations. The system approach to Clinch River Breeder Reactor Plant (CRBRP) radiation protection is described, and the program developed to implement this approach is defined. In addition, the principal shielding design problems for LMFBR nuclear reactor systems are discussed in relation to LWR nuclear reactor system shielding designs. The methodology used to analyze these problems in the U.S. LMFBR program, the resultant design solutions, and the experimental verification of these designs and/or methods are discussed

  12. Design of shielded voltage divider for impulse voltage measurement

    International Nuclear Information System (INIS)

    Kato, Shohei; Kouno, Teruya; Maruyama, Yoshio; Kikuchi, Koji.

    1976-01-01

    The dividers used for the study of the insulation and electric discharge phenomena in high voltage equipments have the problems of the change of response characteristics owing to adjacent bodies and of induced noise. To improve the characteristics, the enclosed type divider shielded with metal has been investigated, and the divider of excellent response has been obtained by adopting the frequency-separating divider system, which is divided into two parts, resistance divider (lower frequency region) and capacitance divider (higher frequency region), for avoiding to degrade the response. Theoretical analysis was carried out in the cases that residual inductance can be neglected or can not be neglected in the small capacitance divider, and that the connecting wires are added. Next, the structure of the divider and the design of the electric field for the divider manufactured on the basis of the theory are described. The response characteristics were measured. The results show that 1 MV impulse voltage can be measured within the response time of 10 ns. Though this divider aims at the impulse voltage, the duration time of which is about that of standard lightning impulse, in view of the heat capacity because of the input resistance of 10.5 kΩ, it is expected that the divider can be applied to the voltage of longer duration time by increasing the input resistance in future. (Wakatsuki, Y.)

  13. Basic nuclear data and reactor shielding design formulaire PROPANE Do

    International Nuclear Information System (INIS)

    Estiot, J.C.; Salvatores, M.; Trapp, J.P.

    1979-01-01

    This paper presents a calculational scheme - formulaire PROPANE - to calculate the deep neutron penetration in the fast reactor shield. The emphasis is put on the multigroup data and method approximations. The performances of this formulaire are presented

  14. Biological shield design for a 10 MeV Rhodotron

    International Nuclear Information System (INIS)

    Khalafi, H.; Ghane, A.; Safaei Arshi, S.; Tabakh, F.

    2012-01-01

    Highlights: ► We evaluate the produced radiations of the Rhodotron-TT200 and their attenuation to the permitted level. ► We apply analytical calculations to determine the shield material and thickness. ► We simulate the Rhodotron accelerator and its shielding using MCNPX code to make sure of results accuracy. -- Abstract: Radiation field of the Rhodotron-TT200 electron accelerator is determined in this study. Regarding the interactions of electron with matter, the produced radiations and their attenuation to the permitted level (i.e. 0.01 mrem/h) are evaluated and calculated. For this purpose analytical calculations are applied to determine the biological shield material and thickness. In order to make sure of results accuracy, Rhodotron accelerator and its shielding are simulated using MCNPX code and the results of analytical calculations and MCNPX code are compared with the experimental ones.

  15. Current status on detail design and fabrication techniques development of ITER blanket shield block in Korea

    International Nuclear Information System (INIS)

    Kim, Duck Hoi; Cho, Seungyon; Ahn, Mu-Young; Lee, Eun-Seok; Jung, Ki Jung

    2007-01-01

    The allocation of components and systems to be delivered to ITER on an in-kind basis, was agreed between the ITER Parties. Among parties, Korea agreed to procure inboard blanket modules 1, 2 and 6, which consists of FW and shield block. Regarding shield block the detail design and Fabrication techniques development have been undertaken in Korea. Especially manufacturing feasibility study on shield block had been performed and some technical issues for the fabrication were selected. Based on these results, fabrication techniques using EB welding are being developed. Meanwhile, the detail design of inboard standard module has been carried out. The optimization of flow driver design to improve the cooling performance was executed. And, thermo-hydraulic analysis on half block of inboard standard module was performed. In this study, current status and some results from Fabrication techniques development on ITER blanket shield block are described. The detail design activity and results on shield block are also introduced herein. (orig.)

  16. Making room in engineering design practices

    DEFF Research Database (Denmark)

    Petersen, Rikke Premer; Buch, Anders

    2016-01-01

    This article aims to explore the challenges that occur from a practice perspective when a new approach to engineering design enters an existing ecology of professional practices in a workplace. Using four empirical episodes, the article illustrates a concrete effort to challenge what counts...... as ‘real engineering’ or what is recognized as part of the engineering expertise. Using an ethnographic, case-studybased research design the article documentshowholistically minded professionals do engineering design ‘by other means’, in ways that strive to promote user experience approaches. The article...... aims to show how engineering practices do not exist in isolation within an organization and how ambitions to transform professional engineering work practices require a change in the very ecologies of practices that exist across an organization...

  17. Comparison of deterministic and Monte Carlo methods in shielding design.

    Science.gov (United States)

    Oliveira, A D; Oliveira, C

    2005-01-01

    In shielding calculation, deterministic methods have some advantages and also some disadvantages relative to other kind of codes, such as Monte Carlo. The main advantage is the short computer time needed to find solutions while the disadvantages are related to the often-used build-up factor that is extrapolated from high to low energies or with unknown geometrical conditions, which can lead to significant errors in shielding results. The aim of this work is to investigate how good are some deterministic methods to calculating low-energy shielding, using attenuation coefficients and build-up factor corrections. Commercial software MicroShield 5.05 has been used as the deterministic code while MCNP has been used as the Monte Carlo code. Point and cylindrical sources with slab shield have been defined allowing comparison between the capability of both Monte Carlo and deterministic methods in a day-by-day shielding calculation using sensitivity analysis of significant parameters, such as energy and geometrical conditions.

  18. Comparison of deterministic and Monte Carlo methods in shielding design

    International Nuclear Information System (INIS)

    Oliveira, A. D.; Oliveira, C.

    2005-01-01

    In shielding calculation, deterministic methods have some advantages and also some disadvantages relative to other kind of codes, such as Monte Carlo. The main advantage is the short computer time needed to find solutions while the disadvantages are related to the often-used build-up factor that is extrapolated from high to low energies or with unknown geometrical conditions, which can lead to significant errors in shielding results. The aim of this work is to investigate how good are some deterministic methods to calculating low-energy shielding, using attenuation coefficients and build-up factor corrections. Commercial software MicroShield 5.05 has been used as the deterministic code while MCNP has been used as the Monte Carlo code. Point and cylindrical sources with slab shield have been defined allowing comparison between the capability of both Monte Carlo and deterministic methods in a day-by-day shielding calculation using sensitivity analysis of significant parameters, such as energy and geometrical conditions. (authors)

  19. Interactive Room Support for Complex and Distributed Design Projects

    DEFF Research Database (Denmark)

    Grønbæk, Kaj; Gundersen, Kristian Kroyer; Mogensen, Preben Holst

    2001-01-01

    We are investigating the design of digital 3D interaction technology embedded in a physical environment. We take as point of departure cemplex, collaborative industrial design projects involving heterogeneous sets of documents, and physical as well as digital 3D models. The paper introduces our...... interaction devices being experimented with in the interactive room environment. The interactive room technologies have all been designed with the requirement that they must seamlessly integrate both into the physical and into the digital work environment while providing new affordances for industrial design...

  20. Optimized design of shields for diagnostic X rays with NCRP 147 technique; Diseno optimizado de blindajes para rayos X diagnostico con tecnica NCRP 147

    Energy Technology Data Exchange (ETDEWEB)

    Gama T, G. [Calidad XXI SA de CV, Zacatecas 67-007 Col. Roma, 06700 Mexico D.F. (Mexico)]. e-mail: cxxi@prodigy.net.mx

    2006-07-01

    A comparison among the design techniques of shielding for X-ray diagnostic rooms with the NCRP 49 (1976) report technique, AAPM 39 (1993) Y the one of the NCRP 147 (2005) technique. The designs correspond to a room of conventional X-rays, one of fluoroscopy, one of tomography Y one of mammography. In all the cases it demonstrates that the NCRP 49 technique overestimate the shieldings. The causes of the overestimation of the NCRP 49 can be attributed to: a) high values of the work charge that don't consider the spectral fluence of the photons that are present in each room, b) to the differences in the values of the kerma in air without attenuation for the dispersed primary radiation Y of leakage among both reports. (Author)

  1. Design of software for calculation of shielding based on various standards radiodiagnostic calculation

    International Nuclear Information System (INIS)

    Falero, B.; Bueno, P.; Chaves, M. A.; Ordiales, J. M.; Villafana, O.; Gonzalez, M. J.

    2013-01-01

    The aim of this study was to develop a software application that performs calculation shields in radiology room depending on the type of equipment. The calculation will be done by selecting the user, the method proposed in the Guide 5.11, the Report 144 and 147 and also for the methodology given by the Portuguese Health Ministry. (Author)

  2. A practical neutron shielding design based on data-base interpolation

    International Nuclear Information System (INIS)

    Jiang, S.H.; Sheu, R.J.

    1993-01-01

    Neutron shielding design is an important part of the construction of nuclear reactors and high-energy accelerators. Neutron shielding design is also indispensable in the packaging and storage of isotopic neutron sources. Most efforts in the development of neutron shielding design have been concentrated on nuclear reactor shielding because of its huge mass and strict requirement of accuracy. Sophisticated computational tools, such as transport and Monte Carlo codes and detailed data libraries have been developed. In principle, now, neutron shielding, in spite of its complexity, can be designed in any detail and with fine accuracy. However, in most practical cases, neutron shielding design is accomplished with simplified methods. Unlike practical gamma-ray shielding design, where exponential attenuation coupled with buildup factors has been applied effectively and accurately, simplified neutron shielding design, either by using removal cross sections or by applying charts or tables of transmission factors such as the National Council on Radiation Protection and Measurements (NCRP) 38 (Ref. 1) for general neutron protection or to NCRP 51 (Ref. 2) for accelerator neutron shielding, is still very primitive and not well established. The available data are limited in energy range, materials, and thicknesses, and the estimated results are only roughly accurate. It is the purpose of this work to establish a simple, convenient, and user-friendly general-purpose computational tool for practical preliminary neutron shielding design that is reasonably accurate. A wide-range (energy, material, and thickness) data base of dose transmission factors has been generated by applying one-dimensional transport calculations in slab geometry

  3. Make Room for Ethnography in Design

    DEFF Research Database (Denmark)

    Simonsen, Jesper; Kensing, Finn

    1998-01-01

    mentioned communities. Some of us have gained our experience from projects in private and public organizations, and those of us also working in academia have included ethnographic techniques in our teaching. Such initiatives represent alternatives neglected by Bader and Nyce, whose assumptions seem...... are concerned about the use-quality of computer based systems. Never the less, Bader and Nyce argue that cultural analysis "will probably not play a significant role in the development process at the least as it is presently defined." We argue that since the design and use of technology is socially constructed......Cultural analysis, especially in its ethnographic form/variant, has been applied for some years now within the Computer Supported Cooperative Work (CSCW), the Human Computer Interaction (HCI), and the Participatory Design (PD) communities. These communities attract academics and practitioners, who...

  4. Radiation shielding design for DECY-13 cyclotron using Monte Carlo method

    International Nuclear Information System (INIS)

    Rasito T; Bunawas; Taufik; Sunardi; Hari Suryanto

    2016-01-01

    DECY-13 is a 13 MeV proton cyclotron with target H_2"1"8O. The bombarding of 13 MeV protons on target H_2"1"8O produce large amounts of neutrons and gamma radiation. It needs the efficient radiation shielding to reduce the level of neutrons and gamma rays to ensure safety for workers and public. Modeling and calculations have been carried out using Monte Carlo method with MCNPX code to optimize the thickness for the radiation shielding. The calculations were done for radiation shielding of rectangular space room type with the size of 5.5 m x 5 m x 3 m and thickness of 170 cm made from lightweight concrete types of portland. It was shown that with this shielding the dose rate outside the wall was reduced to 1 μSv/h. (author)

  5. Structural Design and Thermal Analysis for Thermal Shields of the MICE Coupling Magnets

    International Nuclear Information System (INIS)

    Green, Michael A.; Pan, Heng; Liu, X.K.; Wang, Li; Wu, Hong; Chen, A.B.; Guo, X.L.

    2009-01-01

    A superconducting coupling magnet made from copper matrix NbTi conductors operating at 4 K will be used in the Muon Ionization Cooling Experiment (MICE) to produce up to 2.6 T on the magnet centerline to keep the muon beam within the thin RF cavity indows. The coupling magnet is to be cooled by two cryocoolers with a total cooling capacity of 3 W at 4.2 K. In order to keep a certain operating temperature margin, the most important is to reduce the heat leakage imposed on cold surfaces of coil cold mass assembly. An ntermediate temperature shield system placed between the coupling coil and warm vacuum chamber is adopted. The shield system consists of upper neck shield, main shields, flexible connections and eight supports, which is to be cooled by the first stage cold heads of two ryocoolers with cooling capacity of 55 W at 60 K each. The maximum temperature difference on the shields should be less than 20 K, so the thermal analyses for the shields with different thicknesses, materials, flexible connections for shields' cooling and structure design for heir supports were carried out. 1100 Al is finally adopted and the maximum temperature difference is around 15 K with 4 mm shield thickness. The paper is to present detailed analyses on the shield system design.

  6. Use of the Human Centered Design concept when designing ergonomic NPP control rooms

    International Nuclear Information System (INIS)

    Skrehot, Petr A.; Houser, Frantisek; Riha, Radek; Tuma, Zdenek

    2015-01-01

    Human-Centered Design is a concept aimed at reconciling human needs on the one hand and limitations posed by the design disposition of the room being designed on the other hand. This paper describes the main aspects of application of the Human-Centered Design concept to the design of nuclear power plant control rooms. (orig.)

  7. Study of the radiation scattered and produced by concrete shielding of radiotherapy rooms and its effects on equivalent doses in patients' organs

    International Nuclear Information System (INIS)

    Braga, K.L.; Rebello, W.F.; Andrade, E.R.; Gavazza, S.; Medeiros, M.P.C.; Mendes, R.M.S.; Gomes, R.G.; Silva, M.G.; Thalhofer, J.L.; Silva, A.X.; Santos, R.F.G.

    2015-01-01

    Within a radiotherapy room, in addition to the primary beam, there is also secondary radiation due to the leakage of the accelerator head and the radiation scattering from room objects, patient and even the room's shielding itself, which is projected to protect external individuals disregarding its effects on the patient. This work aims to study the effect of concrete shielding wall over the patient, taking into account its contribution on equivalent doses. The MCNPX code was used to model the linear accelerator Varian 2100/2300 C/D operating at 18MeV, with MAX phantom representing the patient undergoing radiotherapy treatment for prostate cancer following Brazilian Institute of Cancer four-fields radiation application protocol (0°, 90°, 180° and 270°). Firstly, the treatment was patterned within a standard radiotherapy room, calculating the equivalent doses on patient's organs individually. In a second step, this treatment was modeled withdrawing the walls, floor and ceiling from the radiotherapy room, and then the equivalent doses calculated again. Comparing these results, it was found that the concrete has an average shielding contribution of around 20% in the equivalent dose on the patient's organs. (author)

  8. A Survey of Structural Design of Diagnostic X-ray Imaging Facilities and Compliance to Shielding Design Goals in a Limited Resource Setting

    Directory of Open Access Journals (Sweden)

    Flavious B. Nkubli

    2017-11-01

    Full Text Available Purpose: To survey structural designs of x-ray rooms and compliance to shielding design goals of three x-ray imaging facilities. Methods and Materials: The survey was conducted in three radiodiagnostic centers in South East Nigeria, labeled X, Y and Z for anonymity. A stretchable non-elastic meter rule was used to measure x-ray room dimensions. A Vernier caliper was used to measure lead thickness while a calibrated digital survey meter Radalert 100x was used for radiation survey of controlled and uncontrolled areas. Simple statistical tools such as mean and standard deviation were used for analysis with the aid of Microsoft Excel version 2007. Results: Center X had a room dimension of 2.4 m × 2.1 m, Center Y had an x-ray room dimension of 3.6 m × 3.3 m, and Center Z had two x-ray rooms with identical dimensions of 6.3 m × 3.6 m. Measured exit radiation doses for controlled areas in all the centers were: 0.00152 mSv/wk; 0.00496 mSv/wk; 0.00168 mSv/wk; 0.00224 mSv/wk respectively. Lead was the common shielding material used. Conclusion: Based on the parameters studied, Center Z had the ideal room size and layout. Relative distances from the x-ray tubes to the nearest walls were not optimized in all the centers except in Center Z. Measured exit doses were within recommended limits except in Center Y. The location of the control consoles and measured doses were appropriate and within recommended design goals.

  9. Effect of compositional variation in plutonium on process shielding design

    International Nuclear Information System (INIS)

    Brown, T.H.

    1997-11-01

    Radiation dose rate from plutonium with high 239 Pu content varies with initial nuclidic content, radioactive decay time, and impurity elemental content. The two idealized states of old plutonium and clean plutonium, whose initial compositions are given, provide approximate upper and lower bounds on dose rate variation. Whole-body dose rates were calculated for the two composition states, using unshielded and shielded plutonium spheres of varying density. The dose rates from these variable density spheres are similar to those from expanded plutonium configurations encountered during processing. The dose location of 40 cm from the sphere center is representative of operator standoff for direct handling of plutonium inside a glove box. The results have shielding implications for glove boxes with only structurally inherent shielding, especially for processing of old plutonium in an expanded configuration. Further reduction in total dose rate by using lead to reduce photon dose rate is shown for two density cases representing compact and expanded plutonium configurations

  10. Effect of compositional variation in plutonium on process shielding design

    Energy Technology Data Exchange (ETDEWEB)

    Brown, T.H.

    1997-11-01

    Radiation dose rate from plutonium with high {sup 239}Pu content varies with initial nuclidic content, radioactive decay time, and impurity elemental content. The two idealized states of old plutonium and clean plutonium, whose initial compositions are given, provide approximate upper and lower bounds on dose rate variation. Whole-body dose rates were calculated for the two composition states, using unshielded and shielded plutonium spheres of varying density. The dose rates from these variable density spheres are similar to those from expanded plutonium configurations encountered during processing. The dose location of 40 cm from the sphere center is representative of operator standoff for direct handling of plutonium inside a glove box. The results have shielding implications for glove boxes with only structurally inherent shielding, especially for processing of old plutonium in an expanded configuration. Further reduction in total dose rate by using lead to reduce photon dose rate is shown for two density cases representing compact and expanded plutonium configurations.

  11. Future control room design (modernization of control room systems); Zukuenftiges Wartendesign (Modernisierung von Warteneinrichtungen)

    Energy Technology Data Exchange (ETDEWEB)

    Reischl, Ludwig; Freitag, Timo; Dergel, Rene [AREVA NP (Germany). NLLR-G ' ' Reactor I and C' '

    2009-07-01

    In the frame of lifetime extension for nuclear power plants the modernization of the complete safety and operational control technology will be digitalized. It is also recommended to modernize the operator facilities, monitoring systems in the control room, the back-up shut-down center and the local control stations. The authors summarize the reasons for the modernization recommendations and discuss possible solutions for display-oriented control rooms. A concept for control room backfitting includes generic requirements, requirements of the local authorities, ergonomic principles information content and information density, and the design process. The backfitting strategy should include a cooperation with the operational personnel, The quality assurance and training via simulator needs sufficient timing during the implementation of the backfitting.

  12. Design and Shielding of Radiotherapy Treatment Facilities; IPEM Report 75, 2nd Edition

    Science.gov (United States)

    Horton, Patrick; Eaton, David

    2017-07-01

    Design and Shielding of Radiotherapy Treatment Facilities provides readers with a single point of reference for protection advice to the construction and modification of radiotherapy facilities. The book assembles a faculty of national and international experts on all modalities including megavoltage and kilovoltage photons, brachytherapy and high-energy particles, and on conventional and Monte Carlo shielding calculations. This book is a comprehensive reference for qualified experts and radiation-shielding designers in radiation physics and also useful to anyone involved in the design of radiotherapy facilities.

  13. Thermal-hydraulic analysis and design improvement for coolant channel of ITER shield block

    International Nuclear Information System (INIS)

    Zhao Ling; Li Huaqi; Zheng Jiantao; Yi Jingwei; Kang Weishan; Chen Jiming

    2013-01-01

    As an important part for ITER, shield block is used to shield the neutron heat. The structure design of shield block, especially the inner coolant channel design will influence its cooling effect and safety significantly. In this study, the thermal-hydraulic analysis for shield block has been performed by the computational fluid dynamics software, some optimization suggestions have been proposed and thermal-hydraulic characteristics of the improved model has been analyzed again. The analysis results for improved model show that pressure drop through flow path near the inlet and outlet region of the shield block has been reduced, and the total pressure drop in cooling path has been reduced too; the uniformity of the mass flowrate distribution and the velocity distribution have been improved in main cooling branches; the local highest temperature of solid domain reduced considerably, which could avoid thermal stress becoming too large because of coolant effect unevenly. (authors)

  14. Design of a PET/CT facility considering the shielding calculation in accordance with AAPM TG-108

    International Nuclear Information System (INIS)

    Guevara R, V. Y.; Romero C, N.; Berrocal T, M.

    2014-08-01

    A Positron Emission Tomography / Computed Tomography facility may require protection barriers on floor, ceiling and walls, because the patient becomes a radioactive source that emits photons of 0.511 MeV, after having received a radiopharmaceutical, usually F-18 fluorodeoxyglucose (F-18 FDG). This work has as objective to propose the design of a PET/CT facility, taking into account technical and radiation protection considerations applied internationally, and also develop the necessary shielding for such installation by applying as published by the American Association of Physicists in Medicine Task Group Report 108. A shielding spreadsheet in Excel program was developed with reference to the recommendations of the AAPM TG - 08, to determine the shielding required for the walls, floor and ceiling. For fixing the radiation levels in the shielding calculation has been considered the actual restrictions for the occupationally exposed personnel (100 μSv/week) as well as the people in general (20 μSv/ week). The radiopharmaceutical used as a reference for the shielding calculation was the F-18 FDG. With the assistance of an architectural plan were determined distances from potential sources of radiation in facility (uptake and image acquisition living rooms) to points of interest around them. Finally the thickness of the protective barriers in lead and concrete necessary to achieve the established radiation levels were calculated and these results were stored in a table. This paper shows that technical aspects considered in the design of the installation and environments distribution can improve work processes within the PET/CT facility, consequently resulting in a reduction of the dose levels for people in general. (author)

  15. Design and analysis of magnetic shield for 650 MHz SCRF cavity

    International Nuclear Information System (INIS)

    Thakur, Vanshree; Jain, Vikas; Das, S.; Shinde, R.S.; Joshi, S.C.

    2015-01-01

    Five-cell, 650 MHz Superconducting RF (SCRF) cavity is being developed at RRCAT for the Injector Linac of proposed ISNS project. The SCRF cavity needs to be shielded effectively from earth magnetic field. The external magnetic field can cause magnetic field trapping that limits the performance of SCRF cavity. The allowable limit of earth magnetic field in the cavity surface is < 10 mG. The magnetic shielding analysis carried out for 650 MHz dressed SCRF cavity is presented in this paper. For axial magnetic field shielding analysis, 2-D code PANDIRA has been used. A 2-D axisymmetric geometry (cylinder of Cryoperm10 sheet with 460 mm diameter of various thickness and 1100 mm length) has been modelled and analyzed in the presence of 240 mG external axial magnetic field. The influence of partial opening of 120 mm diameter at both ends of the cylinder on magnetic field pattern inside the shielded region has been evaluated. The transverse magnetic shielding analysis in the presence of 500 mG transverse external field has been carried out using OPERA 3D code. The flux leakage through the major openings for cavity supports, ports on the shield is investigated and accordingly the openings are designed to minimize the leakage. Inference of material thickness on the magnetic shielding for reducing magnetic field below specified limit has been investigated. Details of design and analysis of magnetic shield for SCRF cavity will be discussed in this paper. (author)

  16. Control room systems design for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    This publication provides a resource for those who are involved in researching, managing, conceptualizing, designing, manufacturing or backfitting power plant control room systems. It will also be useful to those responsible for performing reviews or evaluations of the design and facilities associated with existing power plant control room systems. The ultimate worth of the publication, however, will depend upon how well it can support its users. Readers are invited to provide comments and observations to the IAEA, Division of Nuclear Power. If appropriate, the report will subsequently be re-issued, taking such feedback into account. Refs, figs and tabs.

  17. Control room systems design for nuclear power plants

    International Nuclear Information System (INIS)

    1995-07-01

    This publication provides a resource for those who are involved in researching, managing, conceptualizing, designing, manufacturing or backfitting power plant control room systems. It will also be useful to those responsible for performing reviews or evaluations of the design and facilities associated with existing power plant control room systems. The ultimate worth of the publication, however, will depend upon how well it can support its users. Readers are invited to provide comments and observations to the IAEA, Division of Nuclear Power. If appropriate, the report will subsequently be re-issued, taking such feedback into account. Refs, figs and tabs

  18. Evaluating secondary neutron doses of a refined shielded design for a medical cyclotron using the TLD approach

    International Nuclear Information System (INIS)

    Lin, Jye-Bin; Tseng, Hsien-Chun; Liu, Wen-Shan; Lin, Ding-Bang; Hsieh, Teng-San; Chen, Chien-Yi

    2013-01-01

    An increasing number of cyclotrons at medical centers in Taiwan have been installed to generate radiopharmaceutical products. An operating cyclotron generates immense amounts of secondary neutrons from reactions such the 18 O(p, n) 18 F, used in the production of FDG. This intense radiation can be hazardous to public health, particularly to medical personnel. To increase the yield of 18 F-FDG from 4200 GBq in 2005 to 48,600 GBq in 2011, Chung Shan Medical University Hospital (CSMUH) has prolonged irradiation time without changing the target or target current to meet requirements regarding the production 18 F. The CSMUH has redesigned the CTI Radioisotope Delivery System shield. The lack of data for a possible secondary neutron doses has increased due to newly designed cyclotron rooms. This work aims to evaluate secondary neutron doses at a CTI cyclotron center using a thermoluminescent dosimeter (TLD-600). Two-dimensional neutron doses were mapped and indicated that neutron doses were high as neutrons leaked through self-shielded blocks and through the L-shaped concrete shield in vault rooms. These neutron doses varied markedly among locations close to the H 2 18 O target. The Monte Carlo simulation and minimum detectable dose are also discussed and demonstrated the reliability of using the TLD-600 approach. Findings can be adopted by medical centers to identify radioactive hot spots and develop radiation protection. - Highlights: • Neutron doses were verified using TLD approach. • Neutron doses were increased at cyclotron centers. • Revised L-shaped shield suppresses effectively the neutrons. • Neutron dose can be attenuated to 1.13×10 6 %

  19. Design of the shield door and transporter for the Culham Conceptual Tokamak Reactor Mark II

    International Nuclear Information System (INIS)

    Guthrie, J.A.S.

    1980-04-01

    In the Culham Conceptual Tokamak Reactor MK II access to the interior for blanket maintenance is through large openings in the fixed shield structure closed by removable shield doors when the reactor is operational. This report describes the design of the 200 tonne doors and the associated special-purpose remote operating transporter manipulator. The design, which has not been optimised, generally uses available commercial equipment and state-of-the-art techniques. (U.K.)

  20. High performance inboard shield design for the compact TIBER-II test reactor: Appendix A-2

    International Nuclear Information System (INIS)

    El-Guebaly, L.A.; Sviatoslavsky, I.N.

    1987-01-01

    The compactness of the TIBER-II reactor has placed a premium on the design of a high performance inboard shield to protect the inner legs of the toroidal field (TF) coils. The available space for shield is constrained to 48 cm and the use of tungsten is mandatory to protect the magnet against the 1.53 MW/m 2 neutron wall loading. The primary requirement for the shield is to limit the fast neutron fluence to 10 19 n/cm 2 . In an optimization study, the performance of various candidate materials for protecting the magnet was examined. The optimum shield consists of a 40 cm thick W layer, followed by an 8 cm thick H 2 O/LiNO 3 layer. The mechanical design of the shield calls for tungsten blocks within SS stiffened panels. All the coolant channels are vertical with more of them in the front where there is a high heat load. The coolant pressure is 0.2 MPa and the maximum structural surface temperature is 0 C. The effects of the detailed mechanical design of the shield and the assembly gaps between the shield sectors on the damage in the magnet were analyzed and peaking factors of ∼2 were found at the hot spots. 2 refs., 6 figs., 2 tabs

  1. The evaluation of radiation dose to embryo/fetus and the design of shielding in the treatment of brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Woong; Huh, Soon Nyung; Chie, Eui Kyu; Ha, Sung Whan; Park, Yang Gyun; Park, Jong Min [Seoul National Univ., Seoul (Korea, Republic of); Park, Suk Won [Chungang Univ., Seoul (Korea, Republic of)

    2006-12-15

    Purpose : To estimate the dose to the embryo/fetus of a pregnant patient with brain tumors, and to design an shielding device to keep the embryo/fetus dose under acceptable levels. Materials and Methods : A shielding wall with the dimension of 1.55 m height, 0.9 m width, and 30 mm thickness is fabricated with 4 trolleys under the wall. It is placed between a patient and the treatment head of a linear accelerator to attenuate the leakage radiation effectively from the treatment head, and is placed 1 cm below the lower margin of the treatment field in order to minimize the dose to a patient from the treatment head. An anti-patient scattering neck supporters with 2 cm thick Cerrobend metal is designed to minimize the scattered radiation from the treatment fields and it is divided into 2 section. They are installed around the patient neck by attach from right and left sides. A shielding bridge for anti-room scattered radiation is utilized to place 2 sheets of 3 mm lead plates above the abdomen to setup three detectors under the lead sheets. Humanoid phantom is irradiated with the same treatment parameters, and with and without shielding devices using TLD, and ionization chambers with and without a build-up cap. Results : The dose to the embryo/fetus without shielding was 3.20, 3.21, 1.44, 0.90 cGy at off-field distances of 30, 40, 50, and 60 cm. With shielding, the dose to embryo/fetus was reduced to 0.88, 0.60, 0.35, 0.25, cGy, and the ratio of the shielding effect varied from 70% to 80%. TLD results were 1.8, 1.2, 0.8, 1.2, and 0.8 cGy. The dose measured by the survey meter was 10.9 mR/h at the patient's surface of abdomen. The dose to the embryo/fetus was estimated to be about 1 cGy during the entire treatment.

  2. Hybrid Magnetic Shielding

    Science.gov (United States)

    Royal, Kevin; Crawford, Christopher; Mullins, Andrew; Porter, Greg; Blanton, Hunter; Johnstone, Connor; Kistler, Ben; Olivera, Daniela

    2017-09-01

    The search for the electric dipole moment of the neutron requires the ambient magnetic field to be on the pT scale which is accomplished with large magnetic shielding rooms. These rooms are fitted with large mu-metal sheets to allow for passive cancellation of background magnetic fields. Active shielding technology cannot uniformly cancel background magnetic fields. These issues can be remedied by combining the methods into a hybrid system. The design used is composed of panels that have an active layer of cancellation between two sheets of mu-metal. The panels form a cube and draw in magnetic fields perpendicular to the surface which can then be reduced using active shielding. This work is supported by the Department of Energy under Contract DE-SC0008107.

  3. Comparison of different methods for shielding design in computed tomography

    International Nuclear Information System (INIS)

    Ciraj-Bjelac, O.; Arandjic, D.; Kosutic, D.

    2011-01-01

    The purpose of this work is to compare different methods for shielding calculation in computed tomography (CT). The BIR-IPEM (British Inst. of Radiology and Inst. of Physics in Engineering in Medicine) and NCRP (National Council on Radiation Protection) method were used for shielding thickness calculation. Scattered dose levels and calculated barrier thickness were also compared with those obtained by scatter dose measurements in the vicinity of a dedicated CT unit. Minimal requirement for protective barriers based on BIR-IPEM method ranged between 1.1 and 1.4 mm of lead demonstrating underestimation of up to 20 % and overestimation of up to 30 % when compared with thicknesses based on measured dose levels. For NCRP method, calculated thicknesses were 33 % higher (27-42 %). BIR-IPEM methodology-based results were comparable with values based on scattered dose measurements, while results obtained using NCRP methodology demonstrated an overestimation of the minimal required barrier thickness. (authors)

  4. Room design for high-performance electron microscopy

    International Nuclear Information System (INIS)

    Muller, David A.; Kirkland, Earl J.; Thomas, Malcolm G.; Grazul, John L.; Fitting, Lena; Weyland, Matthew

    2006-01-01

    Aberration correctors correct aberrations, not instabilities. Rather, as spatial resolution improves, a microscope's sensitivity to room environment becomes more noticeable, not less. Room design is now an essential part of the microscope installation process. Previously ignorable annoyances like computer fans, desk lamps and that chiller in the service corridor now may become the limiting factors in the microscopes performance. We discuss methods to quantitatively characterize the instrument's response to magnetic, mechanical, acoustical and thermal disturbances and thus predict the limits that the environment places on imaging and spectroscopy

  5. Advanced control room design for nuclear power plants

    International Nuclear Information System (INIS)

    Scarola, K.

    1987-01-01

    The power industry has seen a continuous growth of size and complexity of nuclear power plants. Accompanying these changes have been extensive regulatory requirements resulting in significant construction, operation and maintenance costs. In response to related concerns raised by industry members, Combustion Engineering developed the NUPLEX 80 Advanced Control Room. The goal of NUPLEX 80 TM is to: reduce design and construction costs; increase plant safety and availability through improvements in the man-machine interface; and reduce maintenance costs. This paper provides an overview of the NUPLEX 80 Advanced Control Room and explains how the stated goals are achieved. (author)

  6. Interior design criteria for successful hospital patient rooms

    OpenAIRE

    Bilir, Seda

    1997-01-01

    Ankara : The Department of Interior Architecture and Environmental Design and Institute of Fine Arts of Bilkent University, 1997. Thesis (Master's) -- Bilkent University, 1997. Includes bibliographical references leaves 94-99 In this study, the design requirements of hospital acute-care patient rooms, which support the recovery and well-being of the patients, are examined. Patients' psycho-spatial needs which may be complementary to the healing effects of the medical treatme...

  7. SU-F-E-13: Design and Fabrication of Gynacological Brachytherapy Shielding & Non Shielding Applicators Using Indigenously Developed 3D Printing Machine

    Energy Technology Data Exchange (ETDEWEB)

    Shanmugam, S

    2016-06-15

    Purpose: In this innovative work we have developed Gynecological Brachytherapy shielding & Non Shielding Applicators and compared with the commercially available applicators by using the indigenously developed 3D Printing machine. Methods: We have successfully indigenously developed the 3D printing machine. Which contain the 3 dimensional motion platform, Heater unit, base plate, ect… To fabricate the Gynecological Brachytherapy shielding & non shielding applicators the 3D design were developed in the computer as virtual design. This virtual design is made in a CAD computer file using a 3D modeling program. Separate programme for the shielding & non shielding applicators. We have also provided the extra catheter insert provision in the applicator for the multiple catheter. The DICOM file of the applicator were then converted to stereo Lithography file for the 3D printer. The shielding & Non Shielding Applicators were printed on a indigenously developed 3D printer material. The same dimensions were used to develop the applicators in the acrylic material also for the comparative study. A CT scan was performed to establish an infill-density calibration curve as well as characterize the quality of the print such as uniformity and the infill pattern. To commission the process, basic CT and dose properties of the printing materials were measured in photon beams and compared against water and soft tissue. Applicator were then scanned to confirm the placement of multiple catheter position. Finally dose distributions with rescanned CTs were compared with those computer-generated applicators. Results: The doses measured from the ion Chamber and X-Omat film test were within 2%. The shielded applicator reduce the rectal dose comparatively with the non shielded applicator. Conclusion: As of submission 3 unique cylinders have been designed, printed, and tested dosimetrically. A standardizable workflow for commissioning custom 3D printed applicators was codified and will be

  8. SU-F-E-13: Design and Fabrication of Gynacological Brachytherapy Shielding & Non Shielding Applicators Using Indigenously Developed 3D Printing Machine

    International Nuclear Information System (INIS)

    Shanmugam, S

    2016-01-01

    Purpose: In this innovative work we have developed Gynecological Brachytherapy shielding & Non Shielding Applicators and compared with the commercially available applicators by using the indigenously developed 3D Printing machine. Methods: We have successfully indigenously developed the 3D printing machine. Which contain the 3 dimensional motion platform, Heater unit, base plate, ect… To fabricate the Gynecological Brachytherapy shielding & non shielding applicators the 3D design were developed in the computer as virtual design. This virtual design is made in a CAD computer file using a 3D modeling program. Separate programme for the shielding & non shielding applicators. We have also provided the extra catheter insert provision in the applicator for the multiple catheter. The DICOM file of the applicator were then converted to stereo Lithography file for the 3D printer. The shielding & Non Shielding Applicators were printed on a indigenously developed 3D printer material. The same dimensions were used to develop the applicators in the acrylic material also for the comparative study. A CT scan was performed to establish an infill-density calibration curve as well as characterize the quality of the print such as uniformity and the infill pattern. To commission the process, basic CT and dose properties of the printing materials were measured in photon beams and compared against water and soft tissue. Applicator were then scanned to confirm the placement of multiple catheter position. Finally dose distributions with rescanned CTs were compared with those computer-generated applicators. Results: The doses measured from the ion Chamber and X-Omat film test were within 2%. The shielded applicator reduce the rectal dose comparatively with the non shielded applicator. Conclusion: As of submission 3 unique cylinders have been designed, printed, and tested dosimetrically. A standardizable workflow for commissioning custom 3D printed applicators was codified and will be

  9. Effectiveness of shield materials in the design of the PFBR irradiated fuel subassembly shipping cask

    International Nuclear Information System (INIS)

    Radhakrishnan, G.

    2003-01-01

    Fuel subassemblies are irradiated inside the reactor core till they achieve the required burn up and after that they are cooled to permissible decay power level in in-vessel and ex-vessel storage places. Subsequently they are transported to reprocessing plants by means of shipping casks. Shield for the shipping cask has to be designed such a way that it has to comply with the ICRP recommended dose levels of less than 2 mSv/h on contact at the outer surface of the cask and less than 100 mSv/h at 1 m distance from the outer surface of the cask. In this paper, shield design of a typical PFBR irradiated fuel subassembly, which can transport three subassemblies at a time, is narrated. Considering the neutron and fission product and induced gamma rays emitted by typical PFBR irradiated core central subassembly subjected to a maximum burn up, as the source term shield design optimizations have been done. One-dimensional discrete ordinates transport theory computer code ANISN and point kernel computer code QAD-CGGP have been used in complement to carry out the shield design optimizations. Cast-iron, carbon steel, stainless steel 304 and lead and permali have been considered for shield materials. Shield requirements on top, bottom and along the axial height of the shipping cask have also been estimated. (author)

  10. Control room design and human engineering in power plants

    International Nuclear Information System (INIS)

    Herbst, L.; Hinz, W.

    1982-01-01

    The concept for modern plant control rooms is primary influenced by: The automation of protection, binary control and closed loop control functions; organization employing functional areas; computer based information processing; human engineered design. Automation reduces the human work load. Employment of functional areas permits optimization of operational sequences. Computer based information processing makes it possible to output information in accordance with operating requirements. Design based on human engineering principles assures the quality of the interaction between the operator and the equipment. The degree to which these conceptional features play a role in design of power plant control rooms depends on the unit rating, the mode of operation and on the requirements respecting safety and availability of the plant. (orig.)

  11. Design and Fabrication of Radiation Shielded Micro X-Ray Diffraction System

    International Nuclear Information System (INIS)

    Park, Yang Soon; Han, Sun Ho; Ha, Kyeong Yeong; Jee, Kwang Yong

    2006-12-01

    It has been observed that microstructure changes occur at the radial edge of pellet(rim) of the fuel at a high burn-up and extended fuel cycle. The thickness of a rim is some hundreds of micrometers. Despite its narrow range, a rim would affect the behaviour of nuclear fuel. To determine lattice parameter with micro-XRD at intervals as small as 30 - 50 μm in radial direction of irradiated fuel samples, a radiation shielded micro-XRD system was designed and fabricated. This report describes the concept, shielding analysis, the structural design and the fabrication of a radiation shielded glove box for micro-XRD system. This radiation shielded micro-XRD system will be used for analysis of lattice parameter change and the phase distribution at intervals as small as 30 - 50 μm in radial direction of the rim of an irradiated fuel sample and a fuel cladding

  12. Design and Fabrication of Radiation Shielded Micro X-Ray Diffraction System

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yang Soon; Han, Sun Ho; Ha, Kyeong Yeong; Jee, Kwang Yong

    2006-12-15

    It has been observed that microstructure changes occur at the radial edge of pellet(rim) of the fuel at a high burn-up and extended fuel cycle. The thickness of a rim is some hundreds of micrometers. Despite its narrow range, a rim would affect the behaviour of nuclear fuel. To determine lattice parameter with micro-XRD at intervals as small as 30 - 50 {mu}m in radial direction of irradiated fuel samples, a radiation shielded micro-XRD system was designed and fabricated. This report describes the concept, shielding analysis, the structural design and the fabrication of a radiation shielded glove box for micro-XRD system. This radiation shielded micro-XRD system will be used for analysis of lattice parameter change and the phase distribution at intervals as small as 30 - 50 {mu}m in radial direction of the rim of an irradiated fuel sample and a fuel cladding.

  13. Shielding calculations for the design of neutron radiography facility around PARR

    International Nuclear Information System (INIS)

    Ashraf, M.M.; Khan, A.R.

    1989-06-01

    Shielding calculations for neutron radiography facility, proposed to be established around PARR have been carried out using two group diffusion theory and shielding formulae. Gamma radiation penetration calculations have been carried out using simple attenuation methods. The fabrication and installation of the neutron radiography facility would provide the basis for designing a better collimating system and would help establish under water radiography facility for the inspection of highly radioactive materials and components etc. (orig./A.B.)

  14. TORE-SUPRA: design of thermal radiation shield at 80 K

    International Nuclear Information System (INIS)

    Aymar, R.; Cordier, J.J.; Deschamps, P.; Gauthier, A.; Perin, J.P.

    1982-09-01

    The TORE-SUPRA superconducting toroidal magnet operating at liquid helium temperature, must be protected against thermal radiation from the vessels. For this purpose, stainless steel heat shields, cooled at 80 K, are positioned between coil casings at 4.5 K and the vessels, and constitute a double stiff toroid which completely surrounds the magnet. Mockups have been manufactured to study their design and operating problems. Calculations have also been made to analyse the mechanical behaviour of these shields

  15. Measurement of leakage and design for the protective barrier of the high energy radiation therapy room

    International Nuclear Information System (INIS)

    Chu, S.S.; Park, C.Y.

    1981-01-01

    The logical development of an optimum structural shielding design and the computation of protective barriers for high energy radiation therapy room, Toshiba 13 MeV are presented. We obtained following results by comparison in between the precalculating values and actual survey after complete installation of radiogenerating units. 1) The calculating formula for the protective barrier written in NCRP report no. 34(1970) was the most ideal and economic calculating methods for the construction of barrier and to determine thickness for the meeting requirements of the number of patients of 80-100 in daily treatment. 2) The precalculating values of protective barrier are 5 times more protective than that of actual measurement. It is depending on radiation workload and utilization the data most securely. 3) The dose rate during exposure are 2-10 mR/hr at out of the door and the control room. 4) The foul smelling and ozone gas production from long exposure of cancer patients cannot be estimated when the room is ill ventilated. (author)

  16. A Control Room Design Support system using virtual reality

    International Nuclear Information System (INIS)

    Sakuma, Akira; Fukumoto, Akira; Hatanaka, Takahiro; Saijou, Nobuyuki; Masugi, Tsuyoshi

    1999-01-01

    To enhance the efficiency of design and evaluation of the control and monitoring system in the main control room of nuclear power plants, we have been developing a COntrol Room Design Support system (CORDS) using virtual reality technology. Using CORDS, vendor designers and customers can visually check and review human interface design of the proposed control and monitoring systems. The geometry of panels and consoles of the control and monitoring system represented as 3-dimensional static CG (computer graphics) models. Dynamic components, such as control switches, CRT displays and so on, are modeled as dynamic objects in the geometric CG model environment. CORDS is linked with real-time plant simulator. The dynamic objects respond to the corresponding process variables in the simulator, which enables visual evaluation of the response of the control and monitoring system for the various normal and abnormal plant status. The behavior of plant operators can be simulated in 3-dimensional CG control room environment. The operators can be displayed as CG figures and their motions are modeled and controlled based on plant operation manuals. A prototype of CORDS has constructed on a graphics workstation and two engineering workstations. (author)

  17. Design of the magnetized muon shield for the prompt-neutrino facility

    International Nuclear Information System (INIS)

    Baltay, C.; Bosek, N.; Couch, J.

    1982-01-01

    The main technical challenge in the design of the prompt neutrino beam is the magnetized muon shield. Two satisfactory alternate designs have been developed for such a shield during this past year and the background muon fluxes have been calculated by three independent programs at Columbia, Fermilab, and MIT. The background muon fluxes have been calculated to be satisfactory in all of the detectors that might use the beam. In Section III of this report we describe in detail the three Monte Carlo programs used in these calculations. In Section IV we give the details of the flux calculations for the E-613 shield and the comparisons with the observed fluxes with various configurations of that shield. In Section V we describe the designs that have been developed for the neutrino area shield. In Section VI we discuss the problem of proton beam transport losses and the associated muon fluxes. Finally, in Section VII a comparison of the two solutions is made which covers cost, effectiveness, schedule and responsiveness to future unknowns. We conclude that there are not overwhelming reasons for the choice of one design over the other. However, for a variety of secondary reasons the superconducting design offers advantages. We therefore propose the construction of the prompt neutrino facility with the superconducting magnet design

  18. Ergonomic requirements to control room design - evaluation method

    International Nuclear Information System (INIS)

    Hinz, W.

    1985-01-01

    The method of evaluation introduced is the result of work carried out by the sub-committee 'Control Room Design' of the Engineering Standards Committee in DIN Standards, Ergonomy. This committee compiles standards for the design of control rooms (instrumentation and control) for the monitoring and operation of process engineering cycles. With the agreement of the committee - whom we wish to take the opportunity of thanking at this point for their constructive collaboration - a planned partial standard will be introduced thematically in the following, in order that knowledge gained from the discussion can be included in further work on the subject. The matter in question is a procedure for the qualitative evaluation of the duties to be performed under the control of operators in order that an assessment can be made of existing control concepts or such concepts as are to be found in the draft phase. (orig./GL) [de

  19. Design and demonstration of adiabatic quantum-flux-parametron logic circuits with superconductor magnetic shields

    International Nuclear Information System (INIS)

    Inoue, Kenta; Narama, Tatsuya; Yamanashi, Yuki; Yoshikawa, Nobuyuki; Takeuchi, Naoki

    2015-01-01

    Adiabatic quantum-flux-parametron (AQFP) logic is an energy-efficient superconductor logic with zero static power and very small dynamic power due to adiabatic switching operations. In order to build large-scale digital circuits, we built AQFP logic cells using superconductor magnetic shields, which are necessary in order to avoid unwanted magnetic couplings between the cells and excitation currents. In preliminary experimental tests, we confirmed that the unwanted coupling became negligibly small thanks to the superconductor shields. As a demonstration, we designed a four-to-one multiplexor and a 16-junction full adder using the shielded logic cells. In both circuits, we confirmed correct logic operations with wide operation margins of excitation currents. These results indicate that large-scale AQFP digital circuits can be realized using the shielded logic cells. (paper)

  20. The biological shield of a high-intensity spallation source: a monte Carlo design study

    International Nuclear Information System (INIS)

    Koprivnikar, I.; Schachinger, E.

    2004-01-01

    The design of high-intensity spallation sources requires the best possible estimates for the biological shield. The applicability of three-dimensional Monte Carlo simulation in the design of the biological shield of a spallation source will be discussed. In order to achieve reasonable computing times along with acceptable accuracy, biasing techniques are to be employed and it was the main purpose of this work to develop a strategy for an effective Monte Carlo simulation in shielding design. The most prominent MC computer codes, namely MCNPX and FLUKA99, have been applied to the same model spallation source (the European Spallation Source) and on the basis of the derived strategies, the design and characteristics of the target station shield are discussed. It is also the purpose of the paper to demonstrate the application of the developed strategy for the design of beam lines with their shielding using as an example the target-moderator-reflector complex of the ESS as the primary particle source. (author)

  1. Synchrotron radiation shielding design for the Brockhouse sector at the Canadian light source

    International Nuclear Information System (INIS)

    Bassey, Bassey; Moreno, Beatriz; Gomez, Ariel; Ahmed, Asm Sabbir; Ullrich, Doug; Chapman, Dean

    2014-01-01

    At the Canadian Light Source (CLS), the plans for the construction of three beamlines under the Brockhouse Project are underway. The beamlines, to be classified under the CLS Phase III beamlines, will comprise of a wiggler and an undulator, and will be dedicated to x-ray diffraction and scattering experiments. The energy range of these beamlines will be 7–22 keV (low energy wiggler beamline), 20–94 keV (high energy wiggler beamline), and 5–21 keV (undulator beamline). The beamlines will have a total of five hutches. Presented is the shielding design against target scattered white and monochromatic synchrotron radiations for these beamlines. The shielding design is based on: scatter target material-water, dose object-anthropomorphic phantom of the adult human (anteroposterior-AP geometry), and shielding thicknesses of steel and lead that will drop the radiation leakage from the hutches to below 0.5 μSv/h. - Highlights: • The Brockhouse project will add 3 new beamlines at the Canadian Light Source (CLS). • The shielding design against synchrotron radiation was required for these beamlines. • We have completed the required shielding design. • Our design will reduce radiation leakage to <0.5 μSv/h; CLS requires 1.0 μSv/h

  2. Radiation shielding design for the VISTA space craft

    Energy Technology Data Exchange (ETDEWEB)

    Pahyn, S.; Pahyn, H.M. [Gazi Univ., Teknik Eoitim Fakultesi, Ankara (Turkey)

    2001-07-01

    An innovative concept for the direct utilisation of fusion energy with laser ignited (D,T) capsules for propulsion is presented with the so called VISTA (Vehicle for Interplanetary Space Transport Applications) concept. VISTA's overall geometry is that of a 50 degrees-half-angle cone to avoid massive radioactive shielding. The 50 degrees-half-angle maximizes the jet efficiency, and is determined by selecting the optimum pellet firing position along the axis of the cone with respect to the plane of the magnet coil. The pellet firing position is in the vacuum. By a total fusion power production of 17 500 MW with a repetition rate of 5 Hz and 3 500 MJ per shot, the propulsion power in form of charged particles has been calculated as {approx} 7 000 MW, making {approx} 40 % of the total fusion power. About 60 % of the fusion energy is carried by the leaking neutrons out of the pellet. Most of them (96 %) escape into vacuum without striking the space ship. Only 4 % enter the frozen hydrogen exhaust cone (about 50 gr.). Total peak nuclear heat generation in the coils is calculated as 4.7 mW/cm{sup 3}. The peak neutron heating is 1.9 mW/cm{sup 3} and the peak {gamma}-ray heating density is 2.8 mW/cm{sup 3}. However, volume averaged nuclear heat generation in the coils is much lower. It is calculated as 0.18, 0.48 and 0.66 mW/cm{sup 3} for neutron, {gamma}-ray and total nuclear heating, respectively. Net shielding mass is found as 170 ton, making < 3 % of the vehicle mass. (authors)

  3. Radiation shielding design for the VISTA space craft

    International Nuclear Information System (INIS)

    Pahyn, S.; Pahyn, H.M.

    2001-01-01

    An innovative concept for the direct utilisation of fusion energy with laser ignited (D,T) capsules for propulsion is presented with the so called VISTA (Vehicle for Interplanetary Space Transport Applications) concept. VISTA's overall geometry is that of a 50 degrees-half-angle cone to avoid massive radioactive shielding. The 50 degrees-half-angle maximizes the jet efficiency, and is determined by selecting the optimum pellet firing position along the axis of the cone with respect to the plane of the magnet coil. The pellet firing position is in the vacuum. By a total fusion power production of 17 500 MW with a repetition rate of 5 Hz and 3 500 MJ per shot, the propulsion power in form of charged particles has been calculated as ∼ 7 000 MW, making ∼ 40 % of the total fusion power. About 60 % of the fusion energy is carried by the leaking neutrons out of the pellet. Most of them (96 %) escape into vacuum without striking the space ship. Only 4 % enter the frozen hydrogen exhaust cone (about 50 gr.). Total peak nuclear heat generation in the coils is calculated as 4.7 mW/cm 3 . The peak neutron heating is 1.9 mW/cm 3 and the peak γ-ray heating density is 2.8 mW/cm 3 . However, volume averaged nuclear heat generation in the coils is much lower. It is calculated as 0.18, 0.48 and 0.66 mW/cm 3 for neutron, γ-ray and total nuclear heating, respectively. Net shielding mass is found as 170 ton, making < 3 % of the vehicle mass. (authors)

  4. Control room design and human engineering in power plants

    International Nuclear Information System (INIS)

    Herbst, L.; Hinz, W.

    1981-01-01

    Automation reduces the human work load. Employment of functional areas permits optimization of operational sequences. Computer based information processing makes it possible to output information in accordance with operating requirements. Design based on human engineering principles assures the quality of the interaction between the operator and the equipment. The degree to which these conceptional features play a role in design of power plant control rooms depends on the unit rating, the mode of operation and on the requirements respecting safety and availability of the plant. (orig./RW)

  5. Design of control rooms and ergonomics in power plants

    International Nuclear Information System (INIS)

    Herbst, L.; Hinz, W.

    1981-01-01

    Modern power plant control rooms are characterized by automation of protection and control functions, subdivision according to functions, computer-aided information processing, and ergonomic design. Automation relieves the personnel of stress. Subdivision according to functions permits optimized procedures. Computer-aided information processing results in variable information output tailored to the actual needs. Ergonomic design assures qualified man-machine interaction. Of course, these characteristics will vary between power plants in dependence of unit power, mode of operation, and safety and availability requirements. (orig.) [de

  6. Adjoint acceleration of Monte Carlo simulations using TORT/MCNP coupling approach: A case study on the shielding improvement for the cyclotron room of the Buddhist Tzu Chi General Hospital

    International Nuclear Information System (INIS)

    Sheu, R. J.; Sheu, R. D.; Jiang, S. H.; Kao, C. H.

    2005-01-01

    Full-scale Monte Carlo simulations of the cyclotron room of the Buddhist Tzu Chi General Hospital were carried out to improve the original inadequate maze design. Variance reduction techniques are indispensable in this study to facilitate the simulations for testing a variety of configurations of shielding modification. The TORT/MCNP manual coupling approach based on the Consistent Adjoint Driven Importance Sampling (CADIS) methodology has been used throughout this study. The CADIS utilises the source and transport biasing in a consistent manner. With this method, the computational efficiency was increased significantly by more than two orders of magnitude and the statistical convergence was also improved compared to the unbiased Monte Carlo run. This paper describes the shielding problem encountered, the procedure for coupling the TORT and MCNP codes to accelerate the calculations and the calculation results for the original and improved shielding designs. In order to verify the calculation results and seek additional accelerations, sensitivity studies on the space-dependent and energy-dependent parameters were also conducted. (authors)

  7. Japanese contribution to the design of primary module of shielding blanket in ITER-FEAT

    International Nuclear Information System (INIS)

    Kuroda, Toshimasa; Hatano, Toshihisa; Miki, Nobuharu; Hiroki, Seiji; Enoeda, Mikio; Ohmori, Junji; Akiba, Masato

    2003-02-01

    Japanese contributions to the design activity on the shielding blanket module consisting of the separable first wall and the shield block for ITER-FEAT are compiled. Temperature and stress distributions in the first wall and the shield block are analyzed and evaluated with 2-D and 3-D models for steady state and also for transient condition according to plasma ramp-up and ramp-down. While temperatures and stresses in the first wall satisfy their allowable values, those in a front part of the shield block exceed the allowable guideline. Based on this result, design improvements are suggested. Coolant flow and pressure distributions along the complicated coolant channel in the shield block are preliminary analyzed. Though heat removal is satisfactory in all coolant channels, back flows due to choking in coolant collectors are found. Design improvements to avoid the choking are suggested. Electromagnetic forces acting on blanket modules are analyzed with detailed 3-D models of solid elements for different disruption scenarios. The maximum moment around radial axis is 1.36 MNm on module no.5 under fast upward VDE, and the maximum moment around vertical axis is 1.47 MNm on module no.1 under fast downward VDE. The supporting beam of the first wall with welded attachment to the shield block is designed. Required welding thickness and support conditions to withstand electromagnetic forces are estimated. Strength of the shield block at the region mating the flexible cartridge is also estimated. Though the shield block surface attached by the flexible cartridge shows sufficient strength, the internal thread mating the Inconel bolt would need more length. In addition, water-to-water leak detection system in case main supply/return manifolds are located within the vacuum vessel is designed. By using Kr as the tracer material, the possibility of water-to-water leak detection and the concept of the detection system are shown. The design of the shielding blanket of ITER-FEAT has

  8. Proposal of a Technical Design of the ATLAS Forward Region Shielding

    CERN Document Server

    Leroy, C; Palla, J; Pospísil, S; Puchmajer, P; Sodomka, J; Stekl, I

    2002-01-01

    The aim of this note is to present a technical design of the ATLAS forward region. The concept is based on segmented shielding supported by the results of an experiment performed at CERN - PS and Monte Carlo simulations extending these results to ATLAS situation. This concept is translated into a practical engineering design.

  9. Design process and philosophy of TVA's latest advance control room complex

    International Nuclear Information System (INIS)

    Owens, G.R.; Masters, D.W.

    1979-01-01

    TVA's latest nuclear power plant control room design includes a greater emphasis on human factors as compared to their earlier plant designs. This emphasis has resulted in changes in the overall design philosophy and design process. This paper discusses some of the prominent design features of both the control room and the surrounding control room complex. In addition, it also presents some of the important activities involved in the process of developing the advanced control room design

  10. Decontamination of the activation product based on a legal revision of the cyclotron vault room on the non-self-shield compact medical cyclotron

    International Nuclear Information System (INIS)

    Komiya, Isao; Umezu, Yoshiyuki; Fujibuchi, Toshiou; Nakamura, Kazumasa; Baba, Shingo; Honda, Hiroshi

    2016-01-01

    The non-self-shield compact medical cyclotron and the cyclotron vault room were in operation for 27 years. They have now been decommissioned. We efficiently implemented a technique to identify an activation product in the cyclotron vault room. Firstly, the distribution of radioactive concentrations in the concrete of the cyclotron vault room was estimated by calculation from the record of the cyclotron operation. Secondly, the comparison of calculated results with an actual measurement was performed using a NaI scintillation survey meter and a high-purity germanium detector. The calculated values were overestimated as compared to the values measured using the Nal scintillation survey meter and the high-purity germanium detector. However, it could limit the decontamination area. By simulating the activation range, we were able to minimize the concrete core sampling. Finally, the appropriate range of radioactivated area in the cyclotron vault room was decontaminated based on the results of the calculation. After decontamination, the radioactive concentration was below the detection limit value in all areas inside the cyclotron vault room. By these procedures, the decommissioning process of the cyclotron vault room was more efficiently performed. (author)

  11. Design optimization of radiation shielding structure for lead slowing-down spectrometer system

    International Nuclear Information System (INIS)

    Kim, Jeong Dong; Ahn, Sang Joon; Lee, Yong Deok; Park, Chang Je

    2015-01-01

    A lead slowing-down spectrometer (LSDS) system is a promising nondestructive assay technique that enables a quantitative measurement of the isotopic contents of major fissile isotopes in spent nuclear fuel and its pyroprocessing counterparts, such as 235U, 239Pu, 241Pu, and, potentially, minor actinides. The LSDS system currently under development at the Korea Atomic Energy Research Institute (Daejeon, Korea) is planned to utilize a high-flux (>101 2n /cm 2 ·s) neutron source comprised of a high-energy (30 MeV)/high-current (∼2 A) electron beam and a heavy metal target, which results in a very intense and complex radiation field for the facility, thus demanding structural shielding to guarantee the safety. Optimization of the structural shielding design was conducted using MCNPX for neutron dose rate evaluation of several representative hypothetical designs. In order to satisfy the construction cost and neutron attenuation capability of the facility, while simultaneously achieving the aimed dose rate limit (<0.06 μSv/h), a few shielding materials [high-density polyethylene (HDPE)–Borax, B 4 C, and Li 2 CO 3 ] were considered for the main neutron absorber layer, which is encapsulated within the double-sided concrete wall. The MCNP simulation indicated that HDPE-Borax is the most efficient among the aforementioned candidate materials, and the combined thickness of the shielding layers should exceed 100 cm to satisfy the dose limit on the outside surface of the shielding wall of the facility when limiting the thickness of the HDPE-Borax intermediate layer to below 5 cm. However, the shielding wall must include the instrumentation and installation holes for the LSDS system. The radiation leakage through the holes was substantially mitigated by adopting a zigzag-shape with concrete covers on both sides. The suggested optimized design of the shielding structure satisfies the dose rate limit and can be used for the construction of a facility in the near future.

  12. Discussion on the standardization of concrete composition for radiation shielding design 2. Evaluation of the effect of the composition variance on the shielding property

    International Nuclear Information System (INIS)

    Ogata, Tomohiro; Kimura, Ken-ichi; Nakata, Mikihiro; Okuno, Koichi; Ishikawa, Tomoyuki

    2017-01-01

    Radiation Shielding Material Standardization Working Group of AESJ has been organized to establish Japanese standard concrete composition for radiation shielding design. We have collected concrete composition data to organize a representative concrete composition data. Neutron and Gamma dose rates penetrated through several concrete compositions are calculated by one dimensional discrete ordinate code ANISN. Effects of the variation of concrete composition on the neutron and gamma dose are evaluated. In this paper, recent standardization activity is summarized. (author)

  13. The humanization of catheter room design: its clinical practice

    International Nuclear Information System (INIS)

    Lin Hanying; Shi Fengxia; Guo Huiying

    2011-01-01

    American scholar Engeer has proposed biological, psychological and sociological medicine pattern, which has been well accepted by the society, It has manifested the medical arena humanism return and has made the profound influence on the nursing development. The idea, 'the human is a whole', has gradually become the mainstream of the nurse service concept, meanwhile, the environment has more and more become a beneficial part for diagnosing and treating in hospitalization. The improvement and more user-friendly design of the diagnosing and treating environment has already become an important ring linked with the whole nursing work. At the beginning of the fitting up design for the Catheter Lab Room of Interventional Radiology in General Hospital of PLA, the authors receive the idea 'the environment experience and admiration of the patient', put more attention to the humanization in the diagnosing and treating environmental construction. The functional compartments are separated clearly. The color, the background music as well as the video are designed to be coordinated with each other in order to produce a relaxing system. Practice for the past three years indicates that the use of humanization environment design can markedly reduce the patient intense and the anxious level in perioperative period, it can also significantly promote the patient to be restored to health. This article will describe user-friendly diagnosing and treating environmental construction practice in the Catheter Lab Room of Interventional Radiology in General Hospital of PLA. (authors)

  14. The computer code system for reactor radiation shielding in design of nuclear power plant

    International Nuclear Information System (INIS)

    Li Chunhuai; Fu Shouxin; Liu Guilian

    1995-01-01

    The computer code system used in reactor radiation shielding design of nuclear power plant includes the source term codes, discrete ordinate transport codes, Monte Carlo and Albedo Monte Carlo codes, kernel integration codes, optimization code, temperature field code, skyshine code, coupling calculation codes and some processing codes for data libraries. This computer code system has more satisfactory variety of codes and complete sets of data library. It is widely used in reactor radiation shielding design and safety analysis of nuclear power plant and other nuclear facilities

  15. Design, fabrication and commissioning of motorized scanning bed mechanism for shadow shield whole body counting system

    International Nuclear Information System (INIS)

    Arun, B.; Varalakshimi, S.; Manohari, M.; Mathiyarasu, R.

    2012-01-01

    A new scanning bed mechanism for shadow shield counting system is designed, fabricated and commissioned at RSD, IGCAR. The present motorized scanning bed mechanism has varying scan speeds, state of art limit sensors, smooth bed movement, touch screen based software controlled operation parameters with UPS power back-up. In view of the improved personnel safety the entire system has been designed to operate with low voltage power supply (24V). The evaluation demonstrated that the incorporation of the new motorized scanning mechanism has not affected the counting performance of the shadow shield wholebody counting system. (author)

  16. Hospital Patient Room Design: The Issues Facing 23 Occupational Groups Who Work in Medical/Surgical Patient Rooms.

    Science.gov (United States)

    Lavender, Steven A; Sommerich, Carolyn M; Patterson, Emily S; Sanders, Elizabeth B-N; Evans, Kevin D; Park, Sanghyun; Umar, Radin Zaid Radin; Li, Jing

    2015-01-01

    The aim of this study was to learn from a wide range of hospital staff members about how the design of the patient room in which they work adversely affects their ergonomics or hinders their job performance. In addition to providing a healing space for patients, hospital patient rooms need to serve as functional workplaces for the people who provide clinical care, to clean, or to maintain room functions. Therefore, from a design perspective, it is important to understand the needs of all the users of hospital patient rooms with regard to room design. One hundred forty-seven people, representing 23 different occupational stakeholder groups, participated in either focus groups or interviews in which they were asked to identify room design issues that affect the performance of their work tasks. Key issues shared across multiple stakeholder groups included an inability to have eye contact with the patient when entering the room, inadequate space around the bed for the equipment used by stakeholders, the physical demands experienced as stakeholders move furnishings to accomplish their activities or access equipment, and a lack of available horizontal surfaces. Unique issues were also identified for a number of stakeholder groups. There are a number of issues that should be addressed in the next generation of hospital patient rooms, or when refurbishing existing facilities, so that all occupational stakeholder groups can work effectively, efficiently, and without undue physical stress. © The Author(s) 2015.

  17. Design of shielded encircling send-receive type pulsed eddy current probe using numerical analysis method

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Young Kil [Dept. of Electircal Engineeirng, Kunsan National University, Kunsan (Korea, Republic of)

    2013-12-15

    An encircling send-receive type pulsed eddy current (PEC) probe is designed for use in aluminum tube inspection. When bare receive coils located away from the exciter were used, the peak time of the signal did not change although the distance from the exciter increased. This is because the magnetic flux from the exciter coil directly affects the receive coil signal. Therefore, in this work, both the exciter and the sensor coils were shielded in order to reduce the influence of direct flux from the exciter coil. Numerical simulation with the designed shielded encircling PEC probe showed the corresponding increase of the peak time as the sensor distance increased. Ferrite and carbon steel shields were compared and results of the ferrite shielding showed a slightly stronger peak value and a quicker peak time than those of the carbon steel shielding. Simulation results showed that the peak value increased as the defect size (such as depth and length) increased regardless of the sensor location. To decide a proper sensor location, the sensitivity of the peak value to defect size variation was investigated and found that the normalized peak value was more sensitive to defect size variation when the sensor was located closer to the exciter.

  18. Study on the main control room design for Hamaoka Unit No.5

    International Nuclear Information System (INIS)

    Tsuruta, Tadakazu; Sakamoto, Minoru; Maruyama, Tohru; Saito, Tadashi

    2000-01-01

    The main control room of nuclear power station is important to operate the power station and to promote public acceptance of nuclear power station. To enhance them, there is an idea of high ceiling control room with a gallery room located in backside middle upper floor. The control room is expected to enhance habitability and to offer visitors the fine view of the control room. In this study, psychological and physiological influence of such a high ceiling control room design on operators was investigated first. And then some human engineering requirements for desirable main control room were identified. A control room (ceiling height: about 5 meters) adequate to the requirements was designed, and finally the validity of the design was verified by means of full mockup model room tests. The results of this study are applied to the main control room design of Hamaoka Nuclear Power Station Unit No.5 (Chubu Electric Power Co., Inc.) (author)

  19. Shielding technology for high energy radiation production facility

    International Nuclear Information System (INIS)

    Lee, Byung Chul; Kim, Heon Il

    2004-06-01

    In order to develop shielding technology for high energy radiation production facility, references and data for high energy neutron shielding are searched and collected, and calculations to obtain the characteristics of neutron shield materials are performed. For the evaluation of characteristics of neutron shield material, it is chosen not only general shield materials such as concrete, polyethylene, etc., but also KAERI developed neutron shields of High Density PolyEthylene (HDPE) mixed with boron compound (B 2 O 3 , H 2 BO 3 , Borax). Neutron attenuation coefficients for these materials are obtained for later use in shielding design. The effect of source shape and source angular distribution on the shielding characteristics for several shield materials is examined. This effect can contribute to create shielding concept in case of no detail source information. It is also evaluated the effect of the arrangement of shield materials using current shield materials. With these results, conceptual shielding design for PET cyclotron is performed. The shielding composite using HDPE and concrete is selected to meet the target dose rate outside the composite, and the dose evaluation is performed by configuring the facility room conceptually. From the result, the proper shield configuration for this PET cyclotron is proposed

  20. Guide to beamline radiation shielding design at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Ipe, N.; Haeffner, D.R.; Alp, E.E.; Davey, S.C.; Dejus, R.J.; Hahn, U.; Lai, B.; Randall, K.J.; Shu, D.

    1993-11-01

    This document is concerned with the general requirements for radiation shielding common to most Advanced Photon Source (APS) users. These include shielding specifications for hutches, transport, stops, and shutters for both white and monochromatic beams. For brevity, only the results of calculations are given in most cases. So-called open-quotes special situationsclose quotes are not covered. These include beamlines with white beam mirrors for low-pass energy filters (open-quotes pink beamsclose quotes), extremely wide band-pass monochromators (multilayers), or novel insertion devices. These topics are dependent on beamline layout and, as such, are not easily generalized. Also, many examples are given for open-quotes typicalclose quotes hutches or other beamline components. If a user has components that differ greatly from those described, particular care should be taken in following these guidelines. Users with questions on specific special situations should address them to the APS User Technical Interface. Also, this document does not cover specifics on hutch, transport, shutter, and stop designs. Issues such as how to join hutch panels, floor-wall interfaces, cable feed-throughs, and how to integrate shielding into transport are covered in the APS Beamline Standard Components Handbook. It is a open-quotes living documentclose quotes and as such reflects the improvements in component design that are ongoing. This document has the following content. First, the design criteria will be given. This includes descriptions of some of the pertinent DOE regulations and policies, as well as brief discussions of abnormal situations, interlocks, local shielding, and storage ring parameters. Then, the various sources of radiation on the experimental floor are discussed, and the methods used to calculate the shielding are explained (along with some sample calculations). Finally, the shielding recommendations for different situations are given and discussed

  1. A study on radiation shielding design in MACSTOR-400(CANDU spent fuel storage facility)

    International Nuclear Information System (INIS)

    Lee, Yoon Hee

    2006-02-01

    Since the spent fuel pool will be saturated in the near future, spent fuel storage facilities are urgently needed. Because of high radiation and decay heat, spent fuel management is difficult and important. In this study, the shielding thickness of MACSTOR-400 that satisfies the general surface dose rate limit has been investigated. And the radiation shielding safety at site boundary has also been evaluated. IAEA recommends the safety series as a guideline and the U.S. follows the NUREG guide for spent fuel storage facility design. In Japan, the regulation for internal transfer is applied to the spent fuel storage. In Korea, the ACT notification for radiation protection is considered. As a shielding design requirement, it is stated that the occupational exposure dose rate must not exceed 1 mSv/week. From this value, it is assumed that the surface dose rate limit is 25 μSv/hr. And for multi unit operation in same site, the dose rate limit at the controlled area boundary is 0.25 mSv/yr. MCNP code and Microshield program were used for calculating the surface dose rate and the dose rate at site boundary respectively. The shielding should be at least 90 cm thick except the air inlet to follow the surface dose rate limit. Additional shielding is needed on air inlet because the dose rate on air inlet is higher than the dose rate on concrete surface. Without the shielding structure, the shielding thickness should be at least 127 cm. In order to satisfy the surface dose rate limit with maintaining the same concrete thickness on air inlet, shielding structure is required on air inlet. The optimum shielding structure has been proposed in this study. The allowable number of MACSTORs with considering other nuclear facilities in Wolsung site is calculated at 60. It is expected that the required number of MACSTORs are 28 in order to store the total amount of spent fuel generated during NPP operation in Wolsung. Therefore, it seems to be safe in radiation point at site boundary

  2. A study on radiation shielding design in MACSTOR-400(CANDU spent fuel storage facility)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yoon Hee

    2006-02-15

    Since the spent fuel pool will be saturated in the near future, spent fuel storage facilities are urgently needed. Because of high radiation and decay heat, spent fuel management is difficult and important. In this study, the shielding thickness of MACSTOR-400 that satisfies the general surface dose rate limit has been investigated. And the radiation shielding safety at site boundary has also been evaluated. IAEA recommends the safety series as a guideline and the U.S. follows the NUREG guide for spent fuel storage facility design. In Japan, the regulation for internal transfer is applied to the spent fuel storage. In Korea, the ACT notification for radiation protection is considered. As a shielding design requirement, it is stated that the occupational exposure dose rate must not exceed 1 mSv/week. From this value, it is assumed that the surface dose rate limit is 25 μSv/hr. And for multi unit operation in same site, the dose rate limit at the controlled area boundary is 0.25 mSv/yr. MCNP code and Microshield program were used for calculating the surface dose rate and the dose rate at site boundary respectively. The shielding should be at least 90 cm thick except the air inlet to follow the surface dose rate limit. Additional shielding is needed on air inlet because the dose rate on air inlet is higher than the dose rate on concrete surface. Without the shielding structure, the shielding thickness should be at least 127 cm. In order to satisfy the surface dose rate limit with maintaining the same concrete thickness on air inlet, shielding structure is required on air inlet. The optimum shielding structure has been proposed in this study. The allowable number of MACSTORs with considering other nuclear facilities in Wolsung site is calculated at 60. It is expected that the required number of MACSTORs are 28 in order to store the total amount of spent fuel generated during NPP operation in Wolsung. Therefore, it seems to be safe in radiation point at site boundary

  3. Design and evaluation of an inexpensive radiation shield for monitoring surface air temperatures

    Science.gov (United States)

    Zachary A. Holden; Anna E. Klene; Robert F. Keefe; Gretchen G. Moisen

    2013-01-01

    Inexpensive temperature sensors are widely used in agricultural and forestry research. This paper describes a low-cost (~3 USD) radiation shield (radshield) designed for monitoring surface air temperatures in harsh outdoor environments. We compared the performance of the radshield paired with low-cost temperature sensors at three sites in western Montana to several...

  4. Design of calandria-end shield support diaphragm of Narora Atomic Power Project

    Energy Technology Data Exchange (ETDEWEB)

    Srivastava, S K; Nanda Kumar, S; Kakodkar, A

    1975-01-01

    The calandria-end shield diaphragm is one of the important components in Narora Atomic Power Plant. The support diaphragm is designed against elastic and plastic instability failures. Method of analysis for elastic and plastic instability is discussed for normal loading, pipe rupture loading, and earthquake loading.

  5. Structural Shielding Design and Evaluation for Megavoltage X- and Gamma-Ray Radiotherapy Facilities.

    Science.gov (United States)

    Glasgow, Glenn P

    2006-09-01

    Structural Shielding Design and Evaluation for Megavoltage X- and Gamma-Ray Radiotherapy Facilities NCRP Report No. 151, 2005, 246 pp. (Hardcover $100). National Council on Radiation Protection and Measurements, 7910 Woodmont Avenue, Suite 400, Bethesda, MD 20814-3095. ISBN-10 0-0929600-87-8; http://www.NCRPonline.org. © 2006 American Association of Physicists in Medicine.

  6. Design of calandria-end shield support diaphragm of Narora Atomic Power Project

    International Nuclear Information System (INIS)

    Srivastava, S.K.; Nanda Kumar, S.; Kakodkar, A.

    1975-01-01

    The calandria-end shield diaphragm is one of the important components in Narora Atomic Power Plant. The support diaphragm is designed against elastic and plastic instability failures. Method of analysis for elastic and plastic instability is discussed for normal loading, pipe rupture loading and earthquake loading. (author)

  7. Shielding calculation techniques used in the design of fuel storage systems

    International Nuclear Information System (INIS)

    Wang, S.S.; Massey, J.V.

    1986-01-01

    This paper addresses the shielding design and analysis of a concrete modular spent fuel storage system. Particular attention is given to comparing various computation techniques in determining bulk shielding thickness, and also in dealing with the radiation streaming effect through the air exit penetration openings in the module. Three computer codes QADMOD, ANISN, and DOT-IV were used to solve the same problem. In addition, hand albedo calculation were done to augment the result of the QADMOD calculation to properly deal with the surface scattering

  8. Magnetic Shielding Design for Coupler of Wireless Electric Vehicle Charging Using Finite Element Analysis

    Science.gov (United States)

    Zhao, W. N.; Yang, X. J.; Yao, C.; Ma, D. G.; Tang, H. J.

    2017-10-01

    Inductive power transfer (IPT) is a practical and preferable method for wireless electric vehicle (EV) charging which proved to be safe, convenient and reliable. Due to the air gap between the magnetic coupler, the magnetic field coupling decreases and the magnetic leakage increases significantly compared to traditional transformer, and this may lead to the magnetic flux density around the coupler more than the safety limit for human. So magnetic shielding should be adding to the winding made from litz wire to enhance the magnetic field coupling effect in the working area and reduce magnetic field strength in non-working area. Magnetic shielding can be achieved by adding high-permeability material or high-conductivity material. For high-permeability material its magnetic reluctance is much lower than the surrounding air medium so most of the magnetic line goes through the high-permeability material rather than surrounding air. For high-conductivity material the eddy current in the material can produce reverse magnetic field to achieve magnetic shielding. This paper studies the effect of the two types of shielding material on coupler for wireless EV charging and designs combination shielding made from high-permeability material and high-conductivity material. The investigation of the paper is done with the help of finite element analysis.

  9. MIDA - Optimizing control room performance through multi-modal design

    International Nuclear Information System (INIS)

    Ronan, A. M.

    2006-01-01

    Multi-modal interfaces can support the integration of humans with information processing systems and computational devices to maximize the unique qualities that comprise a complex system. In a dynamic environment, such as a nuclear power plant control room, multi-modal interfaces, if designed correctly, can provide complementary interaction between the human operator and the system which can improve overall performance while reducing human error. Developing such interfaces can be difficult for a designer without explicit knowledge of Human Factors Engineering principles. The Multi-modal Interface Design Advisor (MIDA) was developed as a support tool for system designers and developers. It provides design recommendations based upon a combination of Human Factors principles, a knowledge base of historical research, and current interface technologies. MIDA's primary objective is to optimize available multi-modal technologies within a human computer interface in order to balance operator workload with efficient operator performance. The purpose of this paper is to demonstrate MIDA and illustrate its value as a design evaluation tool within the nuclear power industry. (authors)

  10. Shielding and activation calculations around the reactor core for the MYRRHA ADS design

    Science.gov (United States)

    Ferrari, Anna; Mueller, Stefan; Konheiser, J.; Castelliti, D.; Sarotto, M.; Stankovskiy, A.

    2017-09-01

    In the frame of the FP7 European project MAXSIMA, an extensive simulation study has been done to assess the main shielding problems in view of the construction of the MYRRHA accelerator-driven system at SCK·CEN in Mol (Belgium). An innovative method based on the combined use of the two state-of-the-art Monte Carlo codes MCNPX and FLUKA has been used, with the goal to characterize complex, realistic neutron fields around the core barrel, to be used as source terms in detailed analyses of the radiation fields due to the system in operation, and of the coupled residual radiation. The main results of the shielding analysis are presented, as well as the construction of an activation database of all the key structural materials. The results evidenced a powerful way to analyse the shielding and activation problems, with direct and clear implications on the design solutions.

  11. Design of a Shielded Reflection Type Pulsed Eddy Current Probe for the Evaluation of Thickness

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Young Kil; Choi, Dong Myung [Kunsan National University, Gunsan (Korea, Republic of)

    2007-10-15

    For better evaluation of material thickness by using the reflection type pulsed eddy current method, various probe models are designed and their response signals, characteristics, and sensitivities to thickness variation are investigated by a numerical analysis method. Since the sensor needs to detect magnetic fields from eddy currents induced in a test material, not from the exciter coil, two types of models that are shielded by the combination of copper and ferrite and only by ferrite are considered. By studying response signals from these shielded probe models, the peak value and the zero crossing time are selected as useful signal features for the evaluation of material thickness. Investigation of sensitivities of these two features shows that the sensitivity of peak value is more useful than that of zero crossing time and that the probe shielded only by ferrite gives much better sensitivity to thickness variation

  12. Guide to shielding calculations for the design of fluoroscopic laboratory at 503 workshop AVN base Rawalpindi

    International Nuclear Information System (INIS)

    Din, J.U.; Ahmad, M.; Ashraf, M.M.; Khan, A.R.; Khan, A.A.

    1986-11-01

    Non-destructive testing plays an important role in assessing the quality of materials. Various methods are used for this purpose. Radiography by X-rays and gamma-rays is one of the NDT methods used. There are number of mathematical formulae used to estimate the required shielding for an X-ray tube operating at maximum rated voltage or a gamma radiation source having fixed energies. This report covers the shielding requirements for a 150 KV constant potential X-ray unit operating at maximum rated voltage. In addition, the report is a guide for the design of shielded enclosure required for X-rays machines in general. (orig./A.B.)

  13. An investigation of noncompliant toilet room designs for assisted toileting.

    Science.gov (United States)

    Sanford, Jon; Bosch, Sheila J

    2013-01-01

    sidewall and back-wall grab bars. ADA, toilet room design, healthcare design, evidence-based design, human factors, safety, staffPreferred Citation: Sanford, J., & Bosch, S. (2013). An investigation of noncompliant toilet room designs for assisted toileting. Health Environments Research & Design Journal 6(2), pp 43-57.

  14. INTOR radiation shielding for personnel access

    International Nuclear Information System (INIS)

    Gohar, Y.; Abdou, M.

    1981-01-01

    The INTOR reactor shield system consists of the blanket, bulk shield, penetration shield, component shield, and biological shield. The bulk shield consists of two parts: (a) the inboard shield; and (b) the outboard shield. The distinction between the different components of the shield system is essential to satisfy the different design constraints and achieve various objectives

  15. Monte Carlo simulation using MCNP4B for an optimal shielding design of a 252 Cf source

    International Nuclear Information System (INIS)

    Silva, Ademir X. da; Crispim, Verginia R.

    2001-01-01

    This study aim to investigate an optimum shielding design against neutrons and gamma-rays from a source of 252 Cf, using Monte Carlo simulation. The shielding materials studied were: borated polyethylene, borated-lead polyethylene and stainless steel. The Monte Carlo code MCNP, version 4B, was used to design shielding for 252 Cf based neutron irradiator systems. By normalizing the dose equivalent rate values presented to the neutron production rate of the source, the resulting calculations are independents of the intensity of actual 252 Cf source. The results shown what the total dose equivalent rates were reduced significantly by the shielding system optimization. (author)

  16. Neutron transport in structural materials and shielding design

    International Nuclear Information System (INIS)

    Salvatores, M.

    1979-01-01

    In this paper recent development in integral Benchmark experiments and their analysis is reviewed. The main problems related to data and method assesment are also briefly reviewed. In particular, the basic data processing and multigroup structure optimization and the effects of the basic data uncertainty evaluation are stressed. The representativity of an integral experiment from the designer point of view is indicated. Moreover a procedure to deduce design oriented bias factors is outlined. Cross section adjustments are indicated as a useful tool to reduce these bias factors and their uncertainties

  17. SP-100 shield design automation process using expert system and heuristic search techniques

    International Nuclear Information System (INIS)

    Marcille, T.F.; Protsik, R.; Deane, N.A.; Hoover, D.G.

    1993-01-01

    The SP-100 shield subsystem design process has been modified to utilize the GE Corporate Reserch and Development program, ENGINEOUS (Tong 1990). ENGINEOUS is a software system that automates the use of Computer Aided Engineering (CAE) analysis programs in the engineering design process. The shield subsystem design process incorporates a nuclear subsystems design and performance code, a two-dimensional neutral particle transport code, several input processors and two general purpose neutronic output processors. Coupling these programs within ENGINEOUS provides automatic transition paths between applications, with no source code modifications. ENGINEOUS captures human design knowledge, as well as information about the specific CAE applications and stores this information in knowledge base files. The knowledge base information is used by the ENGINEOUS expert system to drive knowledge directed and knowledge supplemented search modules to find an optimum shield design for a given reactor definition, ensuring that specified constraints are satisfied. Alternate designs, not accommodated in the optimization design rules, can readily be explored through the use of a parametric study capability

  18. Design of control rooms. Collaboration between different actors during the design of new and modernized control rooms

    International Nuclear Information System (INIS)

    Johansson, Bjoern J. E.; Gonzalez, Natalia

    2012-01-01

    Swedish nuclear power industry is currently undergoing, as well as planning, a number of upgrades of their control rooms. When changes are made to an NPP, they are conducted within the frame of a design process. The design process controls a number of different domains, such as technical solutions etc, but also affects and is affected by the interactions between Man, Technology and Organisation (MTO). MTO is central for creating safe system solutions. However, in the design process, unplanned events often occur in comparison to what was originally planned. This work aimed to analyse the design process and the involved actors' roles using activity theory with the purpose of creating an understanding of the design process. Activity theory can be seen as a way of understanding individuals and groups and the context they create by analysing the structure and process that their activities are part of. It can therefore be a good tool for analysing the complexity of the design process of a control room. The study has shown that many actors are involved in the design process and that all of them partly drive their own agendas, which may lead to contradictions within the design process. Important conclusions are that it perhaps not is necessary to eliminate all contradictions, but it is important to be aware of them. It is considered, among the informants in the study, that a working communication exists between the actors in the design process, but it is also evident that there is no given method for this, something that also counts for MTO-questions and the communication regarding those. A number of recommendations on how to support the communication process are given. Although there were some difficulties in using activity theory, it is believed that it could be useful for creating an overview of the design process and its actors from different organisations. Activity networks could be bound together in different ways and this provided opportunities to identify possible

  19. Design and fabrication of shielding for gamma spectrometry

    International Nuclear Information System (INIS)

    Mariano H, E.

    1991-05-01

    To have a system of gamma spectrometry in the Radiological Mobile Unit No. 1 (UMOR-1) was designed and manufactured an armor-plating appropriate to this, to make analysis of radioactive samples in place in the event of a radiological emergency, besides being able to give support to the Management of Radiological Safety, and even to give service of sample analysis of other Institutions. (Author)

  20. Nuclear design of the blanket/shield system for a Tokamak Experimental Power Reactor

    International Nuclear Information System (INIS)

    Abdou, M.A.

    1976-01-01

    The various options and trade-offs in the nuclear design of the blanket/shield for a Tokamak Experimental Power Reactor (TEPR) are investigated. The TEPR size and cost are particularly sensitive to the blanket/shield thickness, Δ/sub BS/, on the inner side of the torus. Radition damage to the components of the superconducting magnet and refrigeration power requirements set lower limits on Δ/sub BS/. These limits are developed in terms of TEPR design parameters such as the wall loading, duty cycle, and frequency of magnet anneals. The study of the nuclear performance of various material compositions shows that mixtures of tungsten, or tantalum, or stainless-steel alloys and boron carbide require the smallest Δ/sub BS/ for a given attenuation. This Δ/sub BS/ has to be doubled if the low induced activation materials graphite and aluminum are used. The space problems are greatly eased in the Argonne National Laboratory ANL-TEPR reference design by using two separate segments of the blanket/shield. The inner segment occupies the region of the high magnetic field, uses very efficient attenuators (tungsten- or tantalum- or stainless-steel-boron carbide mixtures), and is only 1 m thick. The outer blanket/shield is 131 cm and consists of an optimized composition of stainless steel and boron carbide. For the design parameters of 0.2 MW/m 2 neutron wall loading and 50 percent duty cycle, the reactor components can operate satisfactorily up to (a) 10 yr for the stainless-steel first wall, (b) 10 yr for the superconductor composite after which magnet warmup becomes necessary, and (c) 30 yr for the Mylar insulation. Nuclear heat generation rates in the blanket/shield and magnet are well within the practical limits for heat removal

  1. The magnetic shield design and simulation of an X-ray spectrometer for Chang'E mission

    International Nuclear Information System (INIS)

    Zhang Jiayu; Wang Huanyu; Zhang Chengmo; Yang Jiawei; Liang Xiaohua; Wang Jinzhou; Cao Xuelei; Gao Min; Cui Xingzhu; Peng Wenxi

    2008-01-01

    Basic design methods about the magnetic shield of an X-ray spectrometer for Chang'E Mission were introduced in this paper. The real magnetic field distribution was obtained through the measure experiment, and according to the measure results, the simulation to evaluate the magnetic shield effect was carded on. The results showed that the collimator can play a good role in magnetic shield to the electron. (authors)

  2. Advanced control room design review guidelines: Merging old and new

    International Nuclear Information System (INIS)

    Carter, R.J.; Wachtel, J.A.

    1992-01-01

    The nuclear power industry is currently developing operator interface systems based on innovative applications of digital computers. To assure that this advanced technology is incorporated in a way that maximizes the potential safety benefits of the technology and minimizes the potential negative effects on human performance, human factors principles must be considered. NUREG-0700 contains guidelines for the review of operator interfaces. However, in light of the rapid technological advances in digital technology which have taken place in the eleven years since its publication, it is no longer adequate to assess the rapidly changing human-system interfaces. A research program, the purpose of which is to upgrade NUREG-0700, has been initiated. Thus far a set of draft advanced control room design review (ACRDR) guidelines has been complied. Three tasks, which were oriented towards integrating the applicable guidelines in NUREG-0700 into the ACRDR document, are described in the paper

  3. The design process and the use of computerized tools in control room design

    International Nuclear Information System (INIS)

    Wahlstroem, B.; Heinonen, R.; Ranta, J.; Haarla, J.

    1985-09-01

    Control room design has proven an important component when the safety and availability of a complex industrial process plant are considered. Many control room deficiencies can be traced back to oversights and other errors during the design process. The introduction of powerful computers and software for computer-aided design (CAD) offers one possibility when tools for improving the quality of design are being selected. The report gives a broad assessment of problems of design and the benefits of using computer-aided design. One proposal for a structure of a computer-aided design system is considered in more detail. In this system special emphasis has been laid on dealing with requirements during design process. A demonstration system has been built and sample system user dialogues are described. The report is the final report of the LIT3.1 project of the Nordic cooperation on human reliability in the energy production field. (author)

  4. Design optimization of radiation shielding structure for lead slowing-down spectrometer system

    Directory of Open Access Journals (Sweden)

    Jeong Dong Kim

    2015-04-01

    Full Text Available A lead slowing-down spectrometer (LSDS system is a promising nondestructive assay technique that enables a quantitative measurement of the isotopic contents of major fissile isotopes in spent nuclear fuel and its pyroprocessing counterparts, such as 235U, 239Pu, 241Pu, and, potentially, minor actinides. The LSDS system currently under development at the Korea Atomic Energy Research Institute (Daejeon, Korea is planned to utilize a high-flux (>1012 n/cm2·s neutron source comprised of a high-energy (30 MeV/high-current (∼2 A electron beam and a heavy metal target, which results in a very intense and complex radiation field for the facility, thus demanding structural shielding to guarantee the safety. Optimization of the structural shielding design was conducted using MCNPX for neutron dose rate evaluation of several representative hypothetical designs. In order to satisfy the construction cost and neutron attenuation capability of the facility, while simultaneously achieving the aimed dose rate limit (<0.06 μSv/h, a few shielding materials [high-density polyethylene (HDPE–Borax, B4C, and Li2CO3] were considered for the main neutron absorber layer, which is encapsulated within the double-sided concrete wall. The MCNP simulation indicated that HDPE-Borax is the most efficient among the aforementioned candidate materials, and the combined thickness of the shielding layers should exceed 100 cm to satisfy the dose limit on the outside surface of the shielding wall of the facility when limiting the thickness of the HDPE-Borax intermediate layer to below 5 cm. However, the shielding wall must include the instrumentation and installation holes for the LSDS system. The radiation leakage through the holes was substantially mitigated by adopting a zigzag-shape with concrete covers on both sides. The suggested optimized design of the shielding structure satisfies the dose rate limit and can be used for the construction of a facility in the near

  5. Design optimization of radiation shielding structure for lead slowing-down spectrometer system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeong Dong; Ahn, Sang Joon; Lee, Yong Deok [Nonproliferation System Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, Chang Je [Dept. of Nuclear Engineering, Sejong University, Seoul (Korea, Republic of)

    2015-04-15

    A lead slowing-down spectrometer (LSDS) system is a promising nondestructive assay technique that enables a quantitative measurement of the isotopic contents of major fissile isotopes in spent nuclear fuel and its pyroprocessing counterparts, such as 235U, 239Pu, 241Pu, and, potentially, minor actinides. The LSDS system currently under development at the Korea Atomic Energy Research Institute (Daejeon, Korea) is planned to utilize a high-flux (>101{sup 2n}/cm{sup 2}·s) neutron source comprised of a high-energy (30 MeV)/high-current (∼2 A) electron beam and a heavy metal target, which results in a very intense and complex radiation field for the facility, thus demanding structural shielding to guarantee the safety. Optimization of the structural shielding design was conducted using MCNPX for neutron dose rate evaluation of several representative hypothetical designs. In order to satisfy the construction cost and neutron attenuation capability of the facility, while simultaneously achieving the aimed dose rate limit (<0.06 μSv/h), a few shielding materials [high-density polyethylene (HDPE)–Borax, B{sub 4}C, and Li{sub 2}CO{sub 3}] were considered for the main neutron absorber layer, which is encapsulated within the double-sided concrete wall. The MCNP simulation indicated that HDPE-Borax is the most efficient among the aforementioned candidate materials, and the combined thickness of the shielding layers should exceed 100 cm to satisfy the dose limit on the outside surface of the shielding wall of the facility when limiting the thickness of the HDPE-Borax intermediate layer to below 5 cm. However, the shielding wall must include the instrumentation and installation holes for the LSDS system. The radiation leakage through the holes was substantially mitigated by adopting a zigzag-shape with concrete covers on both sides. The suggested optimized design of the shielding structure satisfies the dose rate limit and can be used for the construction of a facility in

  6. Islam and the healthcare environment: designing patient rooms.

    Science.gov (United States)

    Kopec, D A K; Han, Li

    2008-01-01

    Islam and the Muslim population are often the source of much misunderstanding and media-influenced misconceptions. Muslim patients who enter the healthcare environment are often weak and likely to experience feelings of vulnerability. Because of the complex and interwoven nature of culture and religion in a person's identity, it is important to consider patient belief systems and values when designing a patient's immediate environment. Through an exploration of literature related to culture and diversity and the beliefs and value system of the Muslim population, the authors were able to identify flexible design initiatives that could accommodate an array of cultural and spiritual practices. Islam and the Muslim population were chosen as the points of reference for this study because of the strong influence of the religion on the culture, and because of the many nuances that differ from the dominant culture within the United States. From these points of reference, a hypothetical design was developed for a patient room that considers differing notions of privacy, alternatives for cultural and religious practices, and ways to include symbolic meaning derived from attributes such as color.

  7. A room of one's own--Being cared for in a hospital with a single-bed room design.

    Science.gov (United States)

    Persson, Eva; Anderberg, Patrice; Ekwall, Anna Kristensson

    2015-06-01

    To illuminate patients' experiences of being hospitalised in a hospital with a single-bed room design. Many patients seem to prefer single-bed hospital rooms. However, studies have also shown that patients do see the advantages of multiple-bed rooms. Interviews were conducted with 16 inpatients from a surgical ward in a hospital building with a single-bed room design. A hermeneutical-phenomenological approach guided by van Manen's four life-world existentials was used to analyse the interviews. The essential meaning was that patients felt secure because they could create a personal environment without disruptive elements. The room was private, and this implied feelings of homeliness, which allowed patients to focus on themselves and was thought to facilitate the recovery process. The patients preferred staying in their room, and the relationship with the personnel was central. Feelings of loneliness and isolation could occur and could be frightening. Being hospitalised in a single-bed room meant balancing between feeling secure and feeling insecure. The following four themes emerged: A homely environment, The need for company and security, Time as unpredictable and involving waiting and Focus on healing the body. Patients experienced that a single-bed room allowed them to focus on their recovery, have visitors without disturbing others and create a feeling of homeliness. However, mobilisation is not a natural part of the recovery process when patients have all they need in their rooms. The patients' need for social interaction and confirmation was not satisfied without effort and planning on the part of staff. © 2014 Nordic College of Caring Science.

  8. Basic design of shield blocks for a spallation neutron source under the high-intensity proton accelerator project

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Katsuhiko; Maekawa, Fujio; Takada, Hiroshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-03-01

    Under the JAERI-KEK High-Intensity Proton Accelerator Project (J-PARC), a spallation neutron source driven by a 3 GeV-1 MW proton beam is planed to be constructed as a main part of the Materials and Life Science Facility. Overall dimensions of a biological shield of the neutron source had been determined by evaluation of shielding performance by Monte Carlo calculations. This report describes results of design studies on an optimum dividing scheme in terms of cost and treatment and mechanical strength of shield blocks for the biological shield. As for mechanical strength, it was studied whether the shield blocks would be stable, fall down or move to a horizontal direction in case of an earthquake of seismic intensity of 5.5 (250 Gal) as an abnormal load. For ceiling shielding blocks being supported by both ends of the long blocks, maximum bending moment and an amount of maximum deflection of their center were evaluated. (author)

  9. Basic design of shield blocks for a spallation neutron source under the high-intensity proton accelerator project

    CERN Document Server

    Yoshida, K; Takada, H

    2003-01-01

    Under the JAERI-KEK High-Intensity Proton Accelerator Project (J-PARC), a spallation neutron source driven by a 3 GeV-1 MW proton beam is planed to be constructed as a main part of the Materials and Life Science Facility. Overall dimensions of a biological shield of the neutron source had been determined by evaluation of shielding performance by Monte Carlo calculations. This report describes results of design studies on an optimum dividing scheme in terms of cost and treatment and mechanical strength of shield blocks for the biological shield. As for mechanical strength, it was studied whether the shield blocks would be stable, fall down or move to a horizontal direction in case of an earthquake of seismic intensity of 5.5 (250 Gal) as an abnormal load. For ceiling shielding blocks being supported by both ends of the long blocks, maximum bending moment and an amount of maximum deflection of their center were evaluated.

  10. Shielding design study for the JAERI/KEK spallation neutron source

    International Nuclear Information System (INIS)

    Maekawa, Fujio; Teshigawara, Makoto; Konno, Chikara; Ikeda, Yujiro; Watanabe, Noboru

    2001-01-01

    Shielding design for the JAERI/KEK spallation neutron source was studied. Bulk shielding characteristics and optimization of a beam shutter were investigated by using Monte Carlo calculation code NMTC/JAM and MCNP with LA-150 neutron cross-section library. The following remarks were derived. (1) Neutron dose outside of the concrete shield at 6.6 m from the center is ∼10 μSv/hr regardless of angles with respect to the proton beam axis. The neutron dose can be reduced more than a factor of 30 by adding natural boron of 5 wt% in the concrete. (2) When a beam shutter position just outside the void vessel and the shutter length of 2 m are assumed, a shutter made of copper (1.7 m) with polyethylene (0.3 m) is the optimum in terms of shielding performance as well as cost merit. A shutter made of tungsten is not so effective. (3) Further studies are needed for optimization of beam shutter position. (author)

  11. Design and fabrication of radiation shielded laser ablation ICP-MS system

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Yeong Keong; Han, Sun Ho; Park, Soon Dal; Park, Yang Soon; Jee, Kwang Yong; Kim, Won Ho

    2006-09-15

    In relation to high burn up and extended fuel cycle for the fuel cycle efficiency, we need to take chemical analysis of spent nuclear fuel for the integrity of nuclear fuel at high burn up. to measure the isotopic distribution of fission product in a high burn up nuclear fuel, radiation shielded laser ablation system was designed and fabricated. By probing the sample with a laser beam, micro sampling system for the mass analyzer was successfully developed. This report describes the structural design and the function of developed radiation shielded LA system. This system will be used for the analysis of isotopic distribution from core to rim of a spent nuclear fuel prepared from the hot-cell in PIE facility and/or an irradiated fuel from research reactor.

  12. Designing 4H-SiC P-shielding trench gate MOSFET to optimize on-off electrical characteristics

    Science.gov (United States)

    Kyoung, Sinsu; Hong, Young-sung; Lee, Myung-hwan; Nam, Tae-jin

    2018-02-01

    In order to enhance specific on-resistance (Ron,sp), the trench gate structure was also introduced into 4H-SiC MOSFET as Si MOSFET. But the 4H-SiC trench gate has worse off-state characteristics than the Si trench gate due to the incomplete gate oxidation process (Šimonka et al., 2017). In order to overcome this problem, P-shielding trench gate MOSFET (TMOS) was proposed and researched in previous studies. But P-shielding has to be designed with minimum design rule in order to protect gate oxide effectively. P-shielding TMOS also has the drawback of on-state characteristics degradation corresponding to off state improvement for minimum design rule. Therefore optimized design is needed to satisfy both on and off characteristics. In this paper, the design parameters were analyzed and optimized so that the 4H-SiC P-shielding TMOS satisfies both on and off characteristics. Design limitations were proposed such that P-shielding is able to defend the gate oxide. The P-shielding layer should have the proper junction depth and concentration to defend the electric field to gate oxide during the off-state. However, overmuch P-shielding junction depth disturbs the on-state current flow, a problem which can be solved by increasing the trench depth. As trench depth increases, however, the breakdown voltage decreases. Therefore, trench depth should be designed with due consideration for on-off characteristics. For this, design conditions and modeling were proposed which allow P-shielding to operate without degradation of on-state characteristics. Based on this proposed model, the 1200 V 4H-SiC P-shielding trench gate MOSFET was designed and optimized.

  13. Bulk-shield design for the Fusion Materials Irradiation Test facility

    International Nuclear Information System (INIS)

    Carter, L.L.; Mann, F.M.; Morford, R.J.; Johnson, D.L.; Huang, S.T.

    1982-07-01

    The accelerator-based Fusion Materials Irradiation Test (FMIT) facility will provide a high-fluence, fusion-like radiation environment for the testing of materials. While the neutron spectrum produced in the forward direction by the 35 MeV deuterons incident upon a flowing lithium target is characterized by a broad peak around 14 MeV, a high energy tail extends up to about 50 MeV. Some shield design considerations are reviewed

  14. Design Considerations for Abrasive Blast Rooms and Recovery Systems

    Science.gov (United States)

    2010-02-01

    COLUMN BOLT – ALLOWS FOR WIDER ENCLOSURES – STRONG ENOUGH TO SUPPORT MONORAIL Flange Bolt Room Column Bolt Room • Structural steel framework...OVERHEAD MONORAILS • EXTERIOR WORK STATIONS • TURNTABLES • HORIZONTAL ROTATION DEVICES OVERHEAD MONORAIL Workpiece Handling • Powered horizontal rotation

  15. Experimental validation of thermal design of top shield for a pool type SFR

    International Nuclear Information System (INIS)

    Aithal, Sriramachandra; Babu, V. Rajan; Balasubramaniyan, V.; Velusamy, K.; Chellapandi, P.

    2016-01-01

    Highlights: • Overall thermal design of top shield in a SFR is experimentally verified. • Air jet cooling is effective in ensuring the temperatures limits for top shield. • Convection patterns in narrow annulus are in line with published CFD results. • Wire mesh insulation ensures gradual thermal gradient at top portion of main vessel. • Under loss of cooling scenario, sufficient time is available for corrective action. - Abstract: An Integrated Top Shield Test Facility towards validation of thermal design of top shield for a pool type SFR has been conceived, constructed & commissioned. Detailed experiments were performed in this experimental facility having full-scale features. Steady state temperature distribution within the facility is measured for various heater plate temperatures in addition to simulating different operating states of the reactor. Following are the important observations (i) jet cooling system is effective in regulating the roof slab bottom plate temperature and thermal gradient across roof slab simulating normal operation of reactor, (ii) wire mesh insulation provided in roof slab-main vessel annulus is effective in obtaining gradual thermal gradient along main vessel top portion and inhibiting the setting up of cellular convection within annulus and (iii) cellular convection with four distinct convective cells sets in the annular gap between roof slab and small rotatable plug measuring ∼ϕ4 m in diameter & gap width varying from 16 mm to 30 mm. Repeatability of results is also ensured during all the above tests. The results presented in this paper is expected to provide reference data for validation of thermal hydraulic models in addition to serving as design validation of jet cooling system for pool type SFR.

  16. Determination of the exposure speed of radiation emitted by the linear accelerator, using the code MCNP5 to evaluate the radiotherapy room shields of ABC Hospital

    International Nuclear Information System (INIS)

    Corral B, J. R.

    2015-01-01

    Humans should avoid exposure to radiation, because the consequences are harmful to health. Although there are different emission sources of radiation, generated by medical devices they are usually of great interest, since people who attend hospitals are exposed in one way or another to ionizing radiation. Therefore, is important to conduct studies on radioactive levels that are generated in hospitals, as a result of the use of medical equipment. To determine levels of exposure speed of a radioactive facility there are different methods, including the radiation detector and computational method. This thesis uses the computational method. With the program MCNP5 was determined the speed of the radiation exposure in the radiotherapy room of Cancer Center of ABC Hospital in Mexico City. In the application of computational method, first the thicknesses of the shields were calculated, using variables as: 1) distance from the shield to the source; 2) desired weekly equivalent dose; 3) weekly total dose equivalent emitted by the equipment; 4) occupation and use factors. Once obtained thicknesses, we proceeded to model the bunker using the mentioned program. The program uses the Monte Carlo code to probabilistic ally determine the phenomena of interaction of radiation with the shield, which will be held during the X-ray emission from the linear accelerator. The results of computational analysis were compared with those obtained experimentally with the detection method, for which was required the use of a Geiger-Muller counter and the linear accelerator was programmed with an energy of 19 MV with 500 units monitor positioning the detector in the corresponding boundary. (Author)

  17. How to Design and Equip a Mentalization-Based Play Therapy Room.

    Science.gov (United States)

    Rüth, Ulrich; Holch, Astrid

    2018-01-01

    Designing and equipping a play therapy room as a differentiated tool in a psychodynamic approach to child psychotherapy is seldom discussed. This article sketches out the equipment and furnishing of a play therapy room to be used for mentalization-based psychodynamic psychotherapy and gives examples of the use of such a room in practice.

  18. Impact of healthcare design on patients' perception of a rheumatology outpatient infusion room

    DEFF Research Database (Denmark)

    Bukh, Gunhild; Tommerup, Anne Marie Munk; Madsen, Ole Rintek

    2015-01-01

    Evidence-based healthcare design is a concept aimed at reducing stress factors in the physical environment for the benefit of patients and the medical staff. The objective of this study was to examine the impact of room modifications on patients' perception of an outpatient infusion room used...... the potential to improve patients' perception of outpatient infusion rooms used for treating rheumatologic diseases....

  19. Design of radiation shielding for the proton therapy facility at the National Cancer Center in Korea

    International Nuclear Information System (INIS)

    Kim, J. W.; Kwon, J. W.; Lee, J.

    2005-01-01

    The design of radiation shielding was evaluated for a proton therapy facility being established at the National Cancer Center in Korea. The proton beam energy from a 230 MeV cyclotron is varied for therapy using a graphite target. This energy variation process produces high radiation and thus thick shielding walls surround the region. The evaluation was first carried out using analytical expressions at selected locations. Further detailed evaluations have been performed using the Monte Carlo method. Dose equivalent values were calculated to be compared with analytical results. The analytical method generally yielded more conservative values. With consideration of adequate occupancy factors annual dose equivalent rates are kept -1 in all areas. Construction of the building is expected to be completed near the end of 2004 and the installation of therapy equipments will begin a few months later. (authors)

  20. A robust helium-cooled shield/blanket design for ITER

    International Nuclear Information System (INIS)

    Wong, C.P.C.; Bourque, R.F.; Baxi, C.B.

    1993-11-01

    General Atomics Fusion and Reactor Groups have completed a helium-cooled, conceptual shield/blanket design for ITER. The configuration selected is a pressurized tubes design embedded in radially oriented plates. This plate can be made from ferritic steel or from V-alloy. Helium leakage to the plasma chamber is eliminated by conservative, redundant design and proper quality control and inspection programs. High helium pressure at 18 MPa is used to reduce pressure drop and enhance heat transfer. This high gas pressure is believed practical when confined in small diameter tubes. Ample industrial experience exists for safe high gas pressure operations. Inboard shield design is highlighted in this study since the allowable void fraction is more limited. Lithium is used as the thermal contacting medium and for tritium breeding, its safety concerns are minimized by a modular, low inventory design that requires no circulation of the liquid metal for the purpose of heat removal. This design is robust, conservative, reliable, and meets all design goals and requirements. It can also be built with present-day technology

  1. Human factors design review guidelines for advanced nuclear control room technologies

    International Nuclear Information System (INIS)

    O'Hara, J.; Brown, W.; Granda, T.; Baker, C.

    1991-01-01

    Advanced control rooms (ACRs) for future nuclear power plants are being designed utilizing computer-based technologies. The US Nuclear Regulatory Commission reviews the human engineering aspects of such control rooms to ensure that they are designed to good human factors engineering principles and that operator performance and reliability are appropriately supported in order to protect public health and safety. This paper describes the rationale, general approach, and initial development of an NRC Advanced Control Room Design Review Guideline. 20 refs., 1 fig

  2. Numerical simulations on active shielding methods comparison and wrapped angle optimization for gradient coil design in MRI with enhanced shielding effect

    Science.gov (United States)

    Wang, Yaohui; Xin, Xuegang; Guo, Lei; Chen, Zhifeng; Liu, Feng

    2018-05-01

    The switching of a gradient coil current in magnetic resonance imaging will induce an eddy current in the surrounding conducting structures while the secondary magnetic field produced by the eddy current is harmful for the imaging. To minimize the eddy current effects, the stray field shielding in the gradient coil design is usually realized by minimizing the magnetic fields on the cryostat surface or the secondary magnetic fields over the imaging region. In this work, we explicitly compared these two active shielding design methods. Both the stray field and eddy current on the cryostat inner surface were quantitatively discussed by setting the stray field constraint with an ultra-low maximum intensity of 2 G and setting the secondary field constraint with an extreme small shielding ratio of 0.000 001. The investigation revealed that the secondary magnetic field control strategy can produce coils with a better performance. However, the former (minimizing the magnetic fields) is preferable when designing a gradient coil with an ultra-low eddy current that can also strictly control the stray field leakage at the edge of the cryostat inner surface. A wrapped-edge gradient coil design scheme was then optimized for a more effective control of the stray fields. The numerical simulation on the wrapped-edge coil design shows that the optimized wrapping angles for the x and z coils in terms of our coil dimensions are 40° and 90°, respectively.

  3. The Conceptional Design of the Shielding Layout and Beam Absorber at the PXIE

    Energy Technology Data Exchange (ETDEWEB)

    Eidelman, Yu.; Kerby, J.; Lebedev, V.; Leibfritz, J.; Leveling, T.; Nagaisev, S.; Stanek, R.; /Fermilab

    2012-05-14

    Project X is a high intensity proton facility conceived to support a world-leading physics program at Fermilab. Project X will provide high intensity beams for neutrino, kaon, muon, and nuclei based experiments and for studies supporting energy applications. The Project X Injector Experiment (PIXIE) is a prototype of the Project X front end. A 30 MeV 50 kW beam will be used to validate the design concept of the Project X. This paper discusses a design of the accelerator enclosure radiation shielding and the beam dump.

  4. Analysis on nuclear power plant control room system design and improvement based on human factor engineering

    International Nuclear Information System (INIS)

    Gao Feng; Liu Yanzi; Sun Yongbin

    2014-01-01

    The design of nuclear power plant control room system is a process of improvement with the implementation of human factor engineering theory and guidance. The method of implementation human factor engineering principles into the nuclear power plant control room system design and improvement was discussed in this paper. It is recommended that comprehensive address should be done from control room system function, human machine interface, digital procedure, control room layout and environment design based on the human factor engineering theory and experience. The main issues which should be paid more attention during the control room system design and improvement also were addressed in this paper, and then advices and notices for the design and improvement of the nuclear power plant control room system were afforded. (authors)

  5. Control room design and human factors using a virtual reality based tool for design, test and training

    International Nuclear Information System (INIS)

    Lirvall, Peter

    1998-02-01

    This report describes a user-centred approach to control room design adopted by IFE for the nuclear industry. The novelty of this approach is the development of a Control Room Philosophy, and the use of Virtual Reality (VR) technology as a tool in the design process, integrated with a specially developed Design Documentation System (DDS) and a process display prototyping tool PICASSO-3. The control room philosophy identifies all functional aspects of a control centre, to define the baseline principles and guidelines for the design. The use of VR technology enables end-users of the control room design (e.g. control room operators) to specify their preferred design of the new control room, and to replace the need for a physical mock-up to test and evaluate the proposed design. The DDS, integrated with the VR design tool, guides the control room operators, through a structured approach, to document the proposed design in a complete design specification. The VR tool, specially developed by IFE, is called the VR based Design, Test and Training tool (VR DTandT). It is not only intended to visualise the design, but also to test and evaluate the design. When the design is implemented, the same model is re-used as a VR based training simulator for operators. A special feature in the VR DTandT tool is that the verification and validation (VandV) tests, concerning human factors, are according to the regulative standards for nuclear control rooms

  6. Mechanical design and analysis for a EPR first wall/blanket/shield system

    International Nuclear Information System (INIS)

    Stevens, H.C.; Misra, B.; Youngdahl, C.K.

    1978-01-01

    Continuing studies are in progress at ANL to expand upon the design of a first wall/blanket/shield FW/B/S system and power conversion for a tokamak type Experimental Power Reactor (EPR). The FW/B/S system has evolved from an earlier design for a low beta, circular cross section plasma (major radius = 6 m) to one for a higher beta elongated plasma with a 4.7 m major radius. Basic mechanical design and layout features of the old and new EPR designs showing some of the more important design developments are given. These developments are aimed at simplifying the design, reducing the costs and in addition, improving the plant thermal efficiency and overall maintainability. In the area of the reactor blanket, significant thermal hydraulic and stress analysis have been performed to substantiate the integrity of the chosen concept. This paper deals with the discussion of these improved features

  7. Material characterisation and preliminary mechanical design for the HL-LHC shielded beam screens operating at cryogenic temperatures

    International Nuclear Information System (INIS)

    Garion, C; Dufay-Chanat, L; Koettig, T; Machiocha, W; Morrone, M

    2015-01-01

    The High Luminosity LHC project (HL-LHC) aims at increasing the luminosity (rate of collisions) in the Large Hadron Collider (LHC) experiments by a factor of 10 beyond the original design value (from 300 to 3000 fb -1 ). It relies on new superconducting magnets, installed close to the interaction points, equipped with new beam screen. This component has to ensure the vacuum performance together with shielding the cold mass from physics debris and screening the cold bore cryogenic system from beam induced heating. The beam screen operates in the range 40-60 K whereas the magnet cold bore temperature is 1.9 K. A tungsten-based material is used to absorb the energy of particles. In this paper, measurements of the mechanical and physical properties of such tungsten material are shown at room and cryogenic temperature. In addition, the design and the thermal mechanical behaviour of the beam screen assembly are presented also. They include the heat transfer from the tungsten absorbers to the cooling pipes and the supporting system that has to minimise the heat inleak into the cold mass. The behaviour during a magnet quench is also presented. (paper)

  8. Material characterisation and preliminary mechanical design for the HL-LHC shielded beam screens operating at cryogenic temperatures

    CERN Document Server

    Garion, C; Koettig, T; Machiocha, W; Morrone, M

    2015-01-01

    The High Luminosity LHC project (HL-LHC) aims at increasing the luminosity (rate of collisions) in the Large Hadron Collider (LHC) experiments by a factor of 10 beyond the original design value (from 300 to 3000 fb-1). It relies on new superconducting magnets, installed close to the interaction points, equipped with new beam screen. This component has to ensure the vacuum performance together with shielding the cold mass from physics debris and screening the cold bore cryogenic system from beam induced heating. The beam screen operates in the range 40-60 K whereas the magnet cold bore temperature is 1.9 K. A tungsten-based material is used to absorb the energy of particles. In this paper, measurements of the mechanical and physical properties of such tungsten material are shown at room and cryogenic temperature. In addition, the design and the thermal mechanical behaviour of the beam screen assembly are presented also. They include the heat transfer from the tungsten absorbers to the cooling pipes and the sup...

  9. Material characterisation and preliminary mechanical design for the HL-LHC shielded beam screens operating at cryogenic temperatures.

    Science.gov (United States)

    Garion, C.; Dufay-Chanat, L.; Koettig, T.; Machiocha, W.; Morrone, M.

    2015-12-01

    The High Luminosity LHC project (HL-LHC) aims at increasing the luminosity (rate of collisions) in the Large Hadron Collider (LHC) experiments by a factor of 10 beyond the original design value (from 300 to 3000 fb-1). It relies on new superconducting magnets, installed close to the interaction points, equipped with new beam screen. This component has to ensure the vacuum performance together with shielding the cold mass from physics debris and screening the cold bore cryogenic system from beam induced heating. The beam screen operates in the range 40-60 K whereas the magnet cold bore temperature is 1.9 K. A tungsten-based material is used to absorb the energy of particles. In this paper, measurements of the mechanical and physical properties of such tungsten material are shown at room and cryogenic temperature. In addition, the design and the thermal mechanical behaviour of the beam screen assembly are presented also. They include the heat transfer from the tungsten absorbers to the cooling pipes and the supporting system that has to minimise the heat inleak into the cold mass. The behaviour during a magnet quench is also presented.

  10. Status of radiation shield design for liquid metal fast breeder reactor spent fuel shipping cask application

    International Nuclear Information System (INIS)

    Dupree, S.A.; Rack, H.J.

    1976-09-01

    Neutron and gamma-ray transport calculations in one-dimensional cylindrical geometry have been performed on a trial reference LMFBR spent-fuel shipping cask that could transport one CRBR subassembly. In the study it was assumed that a layer of depleted U and a layer of neutron shielding materials were sandwiched between 5.08-cm-thick (2-in.) layers of stainless steel. The thicknesses of the internal layers were adjusted until a balanced dose rate (50 percent neuton and 50 percent gamma-ray) of 5 mrem/hr was achieved at a point 1.83 m (6 ft) from the cask surface. Neutron-shield materials considered were LiH, Be, B 4 C, DiH 2 . 5 , and C (graphite). Of these materials, LiH provided the smallest, lightest, and least expensive cask; however, its use would be contigent on expansion of production facilities for LiH and development of a canning or cladding procedure. The B 4 C shielded cask would offer the best alternative if the designs were limited to those using currently available materials

  11. Shielding design of highly activated sample storage at reactor TRIGA PUSPATI

    International Nuclear Information System (INIS)

    Naim Syauqi Hamzah; Julia Abdul Karim; Mohamad Hairie Rabir; Muhd Husamuddin Abdul Khalil; Mohd Amin Sharifuldin Salleh

    2010-01-01

    Radiation protection has always been one of the most important things considered in Reaktor Triga PUSPATI (RTP) management. Currently, demands on sample activation were increased from variety of applicant in different research field area. Radiological hazard may occur if the samples evaluation done were misjudge or miscalculated. At present, there is no appropriate storage for highly activated samples. For that purpose, special irradiated samples storage box should be provided in order to segregate highly activated samples that produce high dose level and typical activated samples that produce lower dose level (1 - 2 mR/ hr). In this study, thickness required by common shielding material such as lead and concrete to reduce highly activated radiotracer sample (potassium bromide) with initial exposure dose of 5 R/ hr to background level (0.05 mR/ hr) were determined. Analyses were done using several methods including conventional shielding equation, half value layer calculation and Micro shield computer code. Design of new irradiated samples storage box for RTP that capable to contain high level gamma radioactivity were then proposed. (author)

  12. Optimal filter design for shielded and unshielded ambient noise reduction in fetal magnetocardiography

    International Nuclear Information System (INIS)

    Comani, S; Mantini, D; Alleva, G; Luzio, S Di; Romani, G L

    2005-01-01

    The greatest impediment to extracting high-quality fetal signals from fetal magnetocardiography (fMCG) is environmental magnetic noise, which may have peak-to-peak intensity comparable to fetal QRS amplitude. Being an unstructured Gaussian signal with large disturbances at specific frequencies, ambient field noise can be reduced with hardware-based approaches and/or with software algorithms that digitally filter magnetocardiographic recordings. At present, no systematic evaluation of filters' performances on shielded and unshielded fMCG is available. We designed high-pass and low-pass Chebychev II-type filters with zero-phase and stable impulse response; the most commonly used band-pass filters were implemented combining high-pass and low-pass filters. The achieved ambient noise reduction in shielded and unshielded recordings was quantified, and the corresponding signal-to-noise ratio (SNR) and signal-to-distortion ratio (SDR) of the retrieved fetal signals was evaluated. The study regarded 66 fMCG datasets at different gestational ages (22-37 weeks). Since the spectral structures of shielded and unshielded magnetic noise were very similar, we concluded that the same filter setting might be applied to both conditions. Band-pass filters (1.0-100 Hz) and (2.0-100 Hz) provided the best combinations of fetal signal detection rates, SNR and SDR; however, the former should be preferred in the case of arrhythmic fetuses, which might present spectral components below 2 Hz

  13. Methods for U.S. shielding calculations: applications to FFTF and CRBR designs

    International Nuclear Information System (INIS)

    Engle, W.W. Jr.; Mynatt, F.R.; Disney, R.K.

    1978-01-01

    The primary components of the U.S. reactor shielding methodology consist of: (1) computer code systems based on discrete ordinates or Monte Carlo radiation transport calculational methods; (2) a data base of neutron and gamma-ray interaction and gamma-ray-production cross sections used as input in the codes; (3) a capability for processing the cross sections into multigroup or point energy formats as required by the codes; (4) large-scale integral shielding experiments designed to test cross-section data or techniques utilized in the calculations; and (5) a ''sensitivity'' analysis capability that can identify the most important interactions in a transport calculation and assign uncertainties to the calculated result that are based on uncertainties in all of the input data. The required accuracy for the methodology is to within 5 to 10% for responses at locations near the core to within a factor of 2 for responses at distant locations. Under these criteria, the methodology has proved to be adequate for in-vessel LMFBR calculations of neutron transport through deep sodium and thick iron and stainless steel shields, of neutron streaming through lower axial coolant channels and primary pipe chaseways, and of the effects of fuel stored within the reactor vessel. For ex-vessel LMFBR problems, the methodology requires considerable improvement, the areas of concern including neutron streaming through heating and ventilation ducts, through the cavity surrounding the reactor vessel, and through gaps around rotating plugs in the reactor heat, as well as gamma-ray streaming through plant shield penetrations

  14. Criteria for the design of the control room complex for a nuclear power generating station

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This Standard addresses the central control room of a nuclear power generating station and the overall complex in which this room is housed. It is not intended to cover special or normally unattended control rooms, such as those provided for radioactive waste handling or for emergency shutdown operations. The nuclear power generating station control room complex provides a protective envelope for plant operating personnel and for instrument and control equipment vital to the operation of the plant during normal and abnormal conditions. In this capacity, the control room complex must be designed and constructed to meet the following criteria contained in Appendix A of 10CFR50, General Design criteria for Nuclear Power Plants: (1) Criterion 2: design bases for protection against natural phenomena; (2) Criterion 3: fire protection; (3) Criterion 4: environmental and missile design bases; (4) Criterion 5: sharing of structures, systems and components (multiunit stations only); and (5) Criterion 19: control room

  15. Designer's guidebook for first wall/blanket/shield assembly, maintenance, and repair

    International Nuclear Information System (INIS)

    1983-01-01

    This is the initial issue of the guidebook. Since a guidebook of this type must incorporate information concerning a wide range of subjects, much additional data will eventually be included. The guidebook will document, in summary and easily referenceable form, data, designs, design concepts, design guidelines and background information useful to the FWBS and to the Maintenance System designer. In providing guidelines for the AMR of the FWBS, the guidebook must, of necessity, include guidelines for all aspects of maintenance associated with the FWBS. These include most maintenance operations within the reactor room necessary to gain access, identify faults, and handle equipment related to FWBS maintenance. In addition, the guidelines include those required to define facility requirements for handling and repair of FWBS and related reactor components external to the reactor room. Particular emphasis is given to remote maintenance design and operations

  16. Designer's guidebook for first wall/blanket/shield assembly, maintenance, and repair

    Energy Technology Data Exchange (ETDEWEB)

    1983-12-30

    This is the initial issue of the guidebook. Since a guidebook of this type must incorporate information concerning a wide range of subjects, much additional data will eventually be included. The guidebook will document, in summary and easily referenceable form, data, designs, design concepts, design guidelines and background information useful to the FWBS and to the Maintenance System designer. In providing guidelines for the AMR of the FWBS, the guidebook must, of necessity, include guidelines for all aspects of maintenance associated with the FWBS. These include most maintenance operations within the reactor room necessary to gain access, identify faults, and handle equipment related to FWBS maintenance. In addition, the guidelines include those required to define facility requirements for handling and repair of FWBS and related reactor components external to the reactor room. Particular emphasis is given to remote maintenance design and operations.

  17. Biological shielding design and qualification of concreting process for construction of electron beam irradiation facility

    International Nuclear Information System (INIS)

    Petwal, V.C.; Kumar, P.; Suresh, N.; Parchani, G.; Dwivedi, J.; Thakurta, A.C.

    2011-01-01

    A technology demonstration facility for irradiation of food and agricultural products is being set-up by RRCAT at Indore. The facility design is based on linear electron accelerator with maximum beam power of 10 kW and can be operated either in electron mode at 10 MeV or photon modes at 5/7.5 MeV. Biological shielding has been designed in accordance with NCRP 51 to achieve dose rate at all accessible points outside the irradiation vault less than the permissible limit of 0.1 mR/hr. In addition to radiation attenuation property, concrete must have satisfactory mechanical properties to meet the structural requirements. There are number of site specific variables which affect the structural, thermal and radiological properties of concrete, leading to considerable difference in actual values and design values. Hence it is essential to establish a suitable site and environmental specific process to cast the concrete and qualify the process by experimental measurement. For process qualification we have cast concrete test blocks of different thicknesses up to 3.25 m and evaluated the radiological and mechanical properties by radiometry, ultrasonic and mechanical tests. In this paper we describe the biological shielding design of the facility and analyse the results of tests carried out for qualification of the process. (author)

  18. A Preliminary Study for Safety Shutter design to Protect Streaming of Residual Radiation Passing through Beamline in Pre-Separator Room of ISOL

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Woo; Kim, Do Hyun; Kim, Song Hyun; Shin, Chang Ho; Nam, Shin Woo [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    RAON is a heavy ion accelerator under construction by the Institute for Basic Science (IBS) in Korea. As one part of the RAON accelerator, ISOL is a facility to generate and separate rare isotopes for various experiments. In ISOL facility, isotopes generated from the reaction between 70 MeV proton beam and UC{sub 2} target are transferred to pre-separator room. Almost all isotopes accumulated in slit of pre-separator except specific isobars, which are set for experiments. Residual radiations are generated from accumulated isotopes because these isotopes are unstable. Streaming of residual radiation by the beamline is weak point for radiation shielding design. In this study, safety shutter was designed. Residual radiation generated from accumulated isotopes at slit of pre-separator was estimated using following conditions: (1) the isotopes generated by proton-target reactions are accumulated at slit with 10 % accumulation rate; (2) it was assumed that the radioactive isotopes are uniformly distributed in the cylindrical slit which have 1 cm height and 15 diameter. To design optimized safety shutter, following steps were performed: (1) thickness and diameter of the bulk shield material were evaluated to optimize safety shutter material; (2) additional shielding structure was proposed using dose contribution of each additional shielding wall.

  19. Neutron shielding studies on an advanced molten salt fast reactor design

    International Nuclear Information System (INIS)

    Merk, Bruno; Konheiser, Jörg

    2014-01-01

    Highlights: • Material damage due to irradiation has already been discovered at the MSRE. • Neutronic analysis of MSFR with curved blanket wall geometry. • Neutron fluence limit at the wall of the outer vessel can be kept for 80 years. • Shielded MSFR core will be of same dimension than a SFR core. - Abstract: The molten salt reactor technology has gained some new interest. In contrast to the historic molten salt reactors, the current projects are based on designing a molten salt fast reactor. Thus the shielding becomes significantly more challenging than in historic concepts. One very interesting and innovative result of the most recent EURATOM project on molten salt reactors – EVOL – is the fluid flow optimized design of the inner reactor vessel using curved blanket walls. The developed structure leads to a very uniform flow distribution. The design avoids all internal structures. Based on this new geometry a model for neutron physics calculation is presented. The major steps are: the modeling of the curved geometry in the unstructured mesh neutron transport code HELIOS and the determination of the real neutron flux and power distribution for this new geometry. The developed model is then used for the determination of the neutron fluence distribution in the inner and outer wall of the system. Based on these results an optimized shielding strategy is developed for the molten salt fast reactor to keep the fluence in the safety related outer vessel below expected limit values. A lifetime of 80 years can be assured, but the size of the core/blanket system will be comparable to a sodium cooled fast reactor. The HELIOS results are verified against Monte-Carlo calculations with very satisfactory agreement for a deep penetration problem

  20. Design of piezoelectric transducer layer with electromagnetic shielding and high connection reliability

    International Nuclear Information System (INIS)

    Qiu, Lei; Yuan, Shenfang; Shi, Xiaoling; Huang, Tianxiang

    2012-01-01

    Piezoelectric transducer (PZT) and Lamb wave based structural health monitoring (SHM) method have been widely studied for on-line SHM of high-performance structures. To monitor large-scale structures, a dense PZTs array is required. In order to improve the placement efficiency and reduce the wire burden of the PZTs array, the concept of the piezoelectric transducers layer (PSL) was proposed. The PSL consists of PZTs, a flexible interlayer with printed wires and signal input/output interface. For on-line SHM on real aircraft structures, there are two main issues on electromagnetic interference and connection reliability of the PSL. To address the issues, an electromagnetic shielding design method of the PSL to reduce spatial electromagnetic noise and crosstalk is proposed and a combined welding–cementation process based connection reliability design method is proposed to enhance the connection reliability between the PZTs and the flexible interlayer. Two experiments on electromagnetic interference suppression are performed to validate the shielding design of the PSL. The experimental results show that the amplitudes of the spatial electromagnetic noise and crosstalk output from the shielded PSL developed by this paper are − 15 dB and − 25 dB lower than those of the ordinary PSL, respectively. Other two experiments on temperature durability ( − 55 °C–80 °C ) and strength durability (160–1600με, one million load cycles) are applied to the PSL to validate the connection reliability. The low repeatability errors (less than 3% and less than 5%, respectively) indicate that the developed PSL is of high connection reliability and long fatigue life. (paper)

  1. Design of piezoelectric transducer layer with electromagnetic shielding and high connection reliability

    Science.gov (United States)

    Qiu, Lei; Yuan, Shenfang; Shi, Xiaoling; Huang, Tianxiang

    2012-07-01

    Piezoelectric transducer (PZT) and Lamb wave based structural health monitoring (SHM) method have been widely studied for on-line SHM of high-performance structures. To monitor large-scale structures, a dense PZTs array is required. In order to improve the placement efficiency and reduce the wire burden of the PZTs array, the concept of the piezoelectric transducers layer (PSL) was proposed. The PSL consists of PZTs, a flexible interlayer with printed wires and signal input/output interface. For on-line SHM on real aircraft structures, there are two main issues on electromagnetic interference and connection reliability of the PSL. To address the issues, an electromagnetic shielding design method of the PSL to reduce spatial electromagnetic noise and crosstalk is proposed and a combined welding-cementation process based connection reliability design method is proposed to enhance the connection reliability between the PZTs and the flexible interlayer. Two experiments on electromagnetic interference suppression are performed to validate the shielding design of the PSL. The experimental results show that the amplitudes of the spatial electromagnetic noise and crosstalk output from the shielded PSL developed by this paper are - 15 dB and - 25 dB lower than those of the ordinary PSL, respectively. Other two experiments on temperature durability ( - 55 °C-80 °C ) and strength durability (160-1600μɛ, one million load cycles) are applied to the PSL to validate the connection reliability. The low repeatability errors (less than 3% and less than 5%, respectively) indicate that the developed PSL is of high connection reliability and long fatigue life.

  2. Shielding analysis in the design phase of the new Emergency Operation Facility for Tihange Nuclear Power Plant

    Science.gov (United States)

    Genard, Gilles; Portal, Romain; Bouchat, Virginie; Vanderperre, Serge

    2017-09-01

    In the framework of the design studies for a new Emergency Operation Facility (EOF) for Tihange NPP, radiation protection analyses are needed to comply with effective dose rate criteria. In this aim, the shielding performed by, at the one hand, external walls and roof of the building and, on the other hand, internal walls, has been sized by means of MicroShield calculations. This paper explains how the calculations for external walls, doors, roof, floor and internal walls are made. The assumptions on the source terms and on the source geometry as well as the way the shielding is determined and the results of the sizing are presented.

  3. Shielding analysis in the design phase of the new Emergency Operation Facility for Tihange Nuclear Power Plant

    Directory of Open Access Journals (Sweden)

    Genard Gilles

    2017-01-01

    Full Text Available In the framework of the design studies for a new Emergency Operation Facility (EOF for Tihange NPP, radiation protection analyses are needed to comply with effective dose rate criteria. In this aim, the shielding performed by, at the one hand, external walls and roof of the building and, on the other hand, internal walls, has been sized by means of MicroShield calculations. This paper explains how the calculations for external walls, doors, roof, floor and internal walls are made. The assumptions on the source terms and on the source geometry as well as the way the shielding is determined and the results of the sizing are presented.

  4. The use of steel and lead shieldings in radiotherapy rooms and its comparison with respect to neutrons doses at patients; Comparacao de blindagens de aco e de chumbo usadas em salas de radioterapia quanto a dose devido a neutrons depositada em pacientes

    Energy Technology Data Exchange (ETDEWEB)

    Silva, M.G.; Rebello, W.F.; Andrade, E.R.; Medeiros, M.P.C.; Mendes, R.M.S.; Braga, K.L.; Gomes, R.G., E-mail: maglosilva15@gmail.com, E-mail: rebello@ime.eb.br, E-mail: fisica.dna@gmail.com, E-mail: eng.cavaliere@gmail.com, E-mail: raphaelmsm@gmail.com, E-mail: kelmo.lins@gmail.com, E-mail: ggrprojetos@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil); Santos, R.F.G., E-mail: raphaelfgsantos@gmail.com [Centro Universitario Anhanguera, Niteroi, RJ (Brazil). Departamento de Engenharia; Silva, Ademir X., E-mail: ademir@con.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The NCRP Report No. 151, Structural Shielding Design and Evaluation for Megavoltage X- and Gamma-Ray Radiotherapy Facilities, considers, in shielding calculations for radiotherapy rooms, the use of lead and/or steel to be applied on bunker walls. The NCRP Report calculations were performed foreseeing a better protection of people outside the radiotherapy room. However, contribution of lead and steel to patient dose should be taken into account for radioprotection purposes. This work presents calculations performed by MCNPX code in analyzing the Ambient Dose Equivalent due to neutron, H*(10){sub n}, within a radiotherapy room, in the patients area, considering the use of additional shielding of 1 TVL of lead or 1 TVL of steel, positioned at the inner faces of walls and ceiling of a bunker. The head of the linear accelerator Varian 2100/2300 C/D was modeled working at 18MeV, with 5x5cm{sup 2}, 10x10cm{sup 2}, 20x20cm{sup 2}, 30x30cm{sup 2} and 40x40cm{sup 2} openings for jaws and MLC and operating in eight gantry's angles. This study shows that the use of lead generates an average value of H*(10){sub n} at patients area, 8.02% higher than the expected when using steel. Further studies should be performed based on experimental data for comparison with those from MCNPX simulation.

  5. Design and implementation of a microprocessor based room ...

    African Journals Online (AJOL)

    This paper describes the development of a microprocessor based room illumination control system that offers advantage of improved efficiency in the use of electrical energy and reduced cost of electricity over manually controlled lighting systems. This system is developed to regulate the intensity of light from direct current ...

  6. Neutron shieldings

    International Nuclear Information System (INIS)

    Tarutani, Kohei

    1979-01-01

    Purpose: To decrease the stresses resulted by the core bendings to the base of an entrance nozzle. Constitution: Three types of round shielding rods of different diameter are arranged in a hexagonal tube. The hexagonal tube is provided with several spacer pads receiving the loads from the core constrain mechanism at its outer circumference, a handling head for a fuel exchanger at its top and an entrance nozzle for self-holding the neutron shieldings and flowing heat-removing coolants at its bottom. The diameters for R 1 , R 2 and R 3 for the round shielding rods are designed as: 0.1 R 1 2 1 and 0.2 R 1 2 1 . Since a plurality of shielding rods of small diameter are provided, soft structure are obtained and a plurality of coolant paths are formed. (Furukawa, Y.)

  7. Shielding benchmark problems

    International Nuclear Information System (INIS)

    Tanaka, Shun-ichi; Sasamoto, Nobuo; Oka, Yoshiaki; Kawai, Masayoshi; Nakazawa, Masaharu.

    1978-09-01

    Shielding benchmark problems were prepared by the Working Group of Assessment of Shielding Experiments in the Research Comittee on Shielding Design of the Atomic Energy Society of Japan, and compiled by the Shielding Laboratory of Japan Atomic Energy Research Institute. Twenty-one kinds of shielding benchmark problems are presented for evaluating the calculational algorithm and the accuracy of computer codes based on the discrete ordinates method and the Monte Carlo method and for evaluating the nuclear data used in the codes. (author)

  8. Optimal design of a composite space shield based on numerical simulations

    International Nuclear Information System (INIS)

    Son, Byung Jin; Yoo, Jeong Hoon; Lee, Min Hyung

    2015-01-01

    In this study, optimal design of a stuffed Whipple shield is proposed by using numerical simulations and new penetration criterion. The target model was selected based on the shield model used in the Columbus module of the international space station. Because experimental results can be obtained only in the low velocity region below 7 km/s, it is required to derive the Ballistic limit curve (BLC) in the high velocity region above 7 km/s by numerical simulation. AUTODYN-2D, the commercial hydro-code package, was used to simulate the nonlinear transient analysis for the hypervelocity impact. The Smoothed particle hydrodynamics (SPH) method was applied to projectile and bumper modeling to represent the debris cloud generated after the impact. Numerical simulation model and selected material properties were validated through a quantitative comparison between numerical and experimental results. A new criterion to determine whether the penetration occurs or not is proposed from kinetic energy analysis by numerical simulation in the velocity region over 7 km/s. The parameter optimization process was performed to improve the protection ability at a specific condition through the Design of experiment (DOE) method and the Response surface methodology (RSM). The performance of the proposed optimal design was numerically verified.

  9. Radiation shielding lead shield

    International Nuclear Information System (INIS)

    Dei, Shoichi.

    1991-01-01

    The present invention concerns lead shields for radiation shielding. Shield boxes are disposed so as to surround a pipeline through which radioactive liquids, mists or like other objects are passed. Flanges are formed to each of the end edges of the shield boxes and the shield boxes are connected to each other by the flanges. Upon installation, empty shield boxes not charged with lead particles and iron plate shields are secured at first at the periphery of the pipeline. Then, lead particles are charged into the shield boxes. This attains a state as if lead plate corresponding to the depth of the box is disposed. Accordingly, operations for installation, dismantling and restoration can be conducted in an empty state with reduced weight to facilitate the operations. (I.S.)

  10. Shielding analysis in the design phase of the new Emergency Operation Facility for Tihange Nuclear Power Plant

    OpenAIRE

    Genard Gilles; Portal Romain; Bouchat Virginie; Vanderperre Serge

    2017-01-01

    In the framework of the design studies for a new Emergency Operation Facility (EOF) for Tihange NPP, radiation protection analyses are needed to comply with effective dose rate criteria. In this aim, the shielding performed by, at the one hand, external walls and roof of the building and, on the other hand, internal walls, has been sized by means of MicroShield calculations. This paper explains how the calculations for external walls, doors, roof, floor and internal walls are made. The assump...

  11. Advancing Control for Shield Tunneling Machine by Backstepping Design with LuGre Friction Model

    Directory of Open Access Journals (Sweden)

    Haibo Xie

    2014-01-01

    Full Text Available Shield tunneling machine is widely applied for underground tunnel construction. The shield machine is a complex machine with large momentum and ultralow advancing speed. The working condition underground is rather complicated and unpredictable, and brings big trouble in controlling the advancing speed. This paper focused on the advancing motion control on desired tunnel axis. A three-state dynamic model was established with considering unknown front face earth pressure force and unknown friction force. LuGre friction model was introduced to describe the friction force. Backstepping design was then proposed to make tracking error converge to zero. To have a comparison study, controller without LuGre model was designed. Tracking simulations of speed regulations and simulations when front face earth pressure changed were carried out to show the transient performances of the proposed controller. The results indicated that the controller had good tracking performance even under changing geological conditions. Experiments of speed regulations were carried out to have validations of the controllers.

  12. RadWorks Storm Shelter Design for Solar Particle Event Shielding

    Science.gov (United States)

    Simon, Matthew A.; Cerro, Jeffrey; Clowdsley, Martha

    2013-01-01

    In order to enable long-duration human exploration beyond low-Earth orbit, the risks associated with exposure of astronaut crews to space radiation must be mitigated with practical and affordable solutions. The space radiation environment beyond the magnetosphere is primarily a combination of two types of radiation: galactic cosmic rays (GCR) and solar particle events (SPE). While mitigating GCR exposure remains an open issue, reducing astronaut exposure to SPEs is achievable through material shielding because they are made up primarily of medium-energy protons. In order to ensure astronaut safety for long durations beyond low-Earth orbit, SPE radiation exposure must be mitigated. However, the increasingly demanding spacecraft propulsive performance for these ambitious missions requires minimal mass and volume radiation shielding solutions which leverage available multi-functional habitat structures and logistics as much as possible. This paper describes the efforts of NASA's RadWorks Advanced Exploration Systems (AES) Project to design minimal mass SPE radiation shelter concepts leveraging available resources. Discussion items include a description of the shelter trade space, the prioritization process used to identify the four primary shelter concepts chosen for maturation, a summary of each concept's design features, a description of the radiation analysis process, and an assessment of the parasitic mass of each concept.

  13. Design for the human-machine interface of a digitalized reactor control-room

    International Nuclear Information System (INIS)

    Qu Ronghong; Zhang Liangju; Li Duo; Yu Hui

    2005-01-01

    Digitalized technology is implemented in the instrumentation and control system of an in-construction research reactor, which advances information display in both contents and styles in a nuclear reactor control-room, and greatly improves human-machine interface. In the design for a digitalized nuclear reactor control-room there are a series of new problems and technologies should be considered seriously. This paper mainly introduces the design for the digitalized control-room of the research nuclear reactor and covered topics include design principle of human-machine interface, organization and classification of interface graphics, technologies and principles based on human factors engineering and implemented in the graphics design. (authors)

  14. Shield nuclear design for the 5-kWe TE system

    International Nuclear Information System (INIS)

    Keshishian, V.

    1972-01-01

    The nuclear analysis of the 5-kW(e) reactor shield is presented. Calculation methods and optimization techniques used are presented. Borated stainless steel was selected for the gamma ray shield with tungsten alloy as an alternate. The total shield weight was calculated to be 355 lb. (U.S.)

  15. Finite volume method room acoustic simulations integrated into the architectural design process

    DEFF Research Database (Denmark)

    Pind Jörgensson, Finnur Kári; Jeong, Cheol-Ho; Engsig-Karup, Allan Peter

    2017-01-01

    with the architectural design from the earliest design stage, as a part of a holistic design process. A new procedure to integrate room acoustics into architectural design is being developed in a Ph.D. project, with the aim of promoting this early stage holistic design process. This project aims to develop a new hybrid...

  16. Review of international standards related to the design for control rooms on nuclear power plants

    International Nuclear Information System (INIS)

    Kitamura, Masashi; Yoshikawa, Hidekazu; Fujita, Yushi

    2005-01-01

    The improvement of Human-Machine Interface (HMI) design for control rooms on nuclear power plants (NPP) has been accomplished world wide, especially after the TMI-2 accident. The design process and guidelines are standardized in IEC60964 and supplemental standards as international standard. However, technological update is required due to the increased use of computerized control and monitoring equipment and systems in control rooms on NPP in recent years. Standards are becoming more important for computerized control rooms because there is more freedom to design than conventional hardware based system. For computerized control rooms, standards for hardware and software of HMI systems should be also considered. Standards and guidelines for computerized control rooms on NPP have been developed recently in each body such as IEC, ISO, and IEEE etc. Therefore, reviewing these standards and guidelines related to control rooms design of NPP can be useful not only for revision of the international standards such as IEC60964, but also for users of the standards and guidelines. In this paper, we reviewed the international standards related to the design for control rooms, in the two aspects of HMI design and hardware and software design, considering the undergoing revision work and their application. (author)

  17. Functional components for a design strategy: Hot cell shielding in the high reliability safeguards methodology

    Energy Technology Data Exchange (ETDEWEB)

    Borrelli, R.A., E-mail: rborrelli@uidaho.edu

    2016-08-15

    The high reliability safeguards (HRS) methodology has been established for the safeguardability of advanced nuclear energy systems (NESs). HRS is being developed in order to integrate safety, security, and safeguards concerns, while also optimizing these with operational goals for facilities that handle special nuclear material (SNM). Currently, a commercial pyroprocessing facility is used as an example system. One of the goals in the HRS methodology is to apply intrinsic features of the system to a design strategy. This current study investigates the thickness of the hot cell walls that could adequately shield processed materials. This is an important design consideration that carries implications regarding the formation of material balance areas, the location of key measurement points, and material flow in the facility.

  18. Radiation calculations and shielding considerations for the design of the Next Linear Collider

    International Nuclear Information System (INIS)

    Nelson, W.R.; Rokni, S.H.; Vylet, V.

    1996-11-01

    The authors describe some of the work that they have done as a contribution to the Next Linear Collider (NLC) Zeroth-Order Design Report (ZDR), with specific emphasis placed on radiation-protection issues. However, because of the very nature of this machine--namely, extremely-small beam spots of high intensity--a new approach in accelerator radiation-protection philosophy appears to be warranted. Accordingly, the presentation will first take a look at recent design studies directed at protecting the machine itself, since this has resulted in a much better understanding of the very short exposure times involved whenever beam is lost and radiation sources are created. At the end of the paper, the authors suggest a Beam Containment System (BCS) that would provide an independent, redundant guarantee that exposure times are, indeed, kept very short. This, in turn, has guided them in the determination of the transverse shield thickness for the machine

  19. Design of the segment structure and coolant ducts for a fusion reactor blanket and shield

    International Nuclear Information System (INIS)

    Briaris, D.A.; Stanbridge, J.R.

    1978-05-01

    An outline design and analysis of a support structure for the replaceable first wall of a helium cooled fusion reactor blanket has been undertaken. The proposed structure supports all the segment gravitational loads with maximum deflections limited to < 10 mm, and is itself supported off the outer shield by a simple vee-in-groove arrangement. It is a feature of the design that the coaxial coolant pipes and the segment structure operate at the same temperature, making it possible for them to be integrated, thereby avoiding the necessity for pipe bellows. The requirements of cooling the inner arm of the structure and increasing the major radius of the torus by approximately = 0.5 m, have been identified as problems associated with the 'horseshoe' shaped structure applicable to the reactor with divertor. For a ring structure, i.e. reactor without divertor, these problems do not arise. (author)

  20. Human factors engineering control-room-design review/audit report: Palo Verde Nuclear Generating Station, Arizona Public Service Company

    International Nuclear Information System (INIS)

    Savage, J.W.; Lappa, D.A.

    1981-01-01

    A human factors engineering design review of the Palo Verde control room simulator was performed at the site on September 15 through September 17, 1981. Observed human factors design discrepancies were given priority ratings. This report summarizes the team's observations of the control room design and layout and of the control room operators' interface with the control room environment. A list of the human factors strengths observed in the Palo Verde control room simulator is given

  1. Design, fabrication, and properties of a continuous carbon-fiber reinforced Sm_2O_3/polyimide gamma ray/neutron shielding material

    International Nuclear Information System (INIS)

    Wang, Peng; Tang, Xiaobin; Chai, Hao; Chen, Da; Qiu, Yunlong

    2015-01-01

    Highlights: • Sm_2O_3 is used for neutron absorber instead of B_4C, and Sm_2O_3 has a good photon-shielding effect. • Carbon-fiber cloth and polyimide were used to enhance shielding materials’ mechanical behavior and thermal behavior. • Both Monte Carlo method and shielding test were used to evaluate shielding performance of the novel shielding material. - Abstract: The design and fabrication of shielding materials with good heat-resistance and mechanical properties is a major problem in the radiation shielding field. In this paper, based on gamma ray and neutron shielding theory, a continuous carbon-fiber reinforced Sm_2O_3/polyimide gamma ray/neutron shielding material was fabricated by hot-pressing method. The material's application behavior was subsequently evaluated using neutron shielding, photon shielding, mechanical tensile, and thermogravimetric analysis–differential scanning calorimetry tests. The results show that the tensile strength of the novel shielding material exceeds 200 MPa, which makes it of similar strength to aluminum alloy. The material does not undergo crosslinking and decomposition reactions at 300 °C and it can be used in such environments for long periods of time. The continuous carbon-fiber reinforced Sm_2O_3/polyimide material has a good shielding performance with respect to gamma rays and neutrons. The material thus has good prospects for use in fusion reactor system and nuclear waste disposal applications.

  2. Research on design method of main control room intake air radioactive monitoring

    International Nuclear Information System (INIS)

    Li Lei; Sun Yu; Wang Jiaoya; Liu Hongtao

    2014-01-01

    According to the design of the main control room intake gamma radiation dose rate monitoring channels in CPR1000 project and the study of relevant regulations and standards, a design method of main control room air inlet radioactive monitoring was presented. The measured object, equipment layout and chain operation were described. The threshold setting was explored using a calculation model established by MCNP software. The advantages, disadvantages and improvement ideas of this design were presented on the basis of calculation results. (authors)

  3. Validation of PHITS Spallation Models from the Perspective of the Shielding Design of Transmutation Experimental Facility

    Science.gov (United States)

    Iwamoto, Hiroki; Meigo, Shin-ichiro

    2017-09-01

    The impact of different spallation models implemented in the particle transport code PHITS on the shielding design of Transmutation Experimental Facility is investigated. For 400-MeV proton incident on a lead-bismuth eutectic target, an effective dose rate at the end of a thick radiation shield (3-m-thick iron and 3-m-thick concrete) calculated by the Liège intranuclear cascade (INC) model version 4.6 (INCL4.6) coupled with the GEMcode (INCL4.6/GEM) yields about twice as high as the Bertini INC model (Bertini/GEM). A comparison with experimental data for 500-MeV proton incident on a thick lead target suggest that the prediction accuracy of INCL4.6/GEM would be better than that of Bertini/GEM. In contrast, it is found that the dose rates in beam ducts in front of targets calculated by the INCL4.6/GEMare lower than those by the Bertini/GEM. Since both models underestimate the experimental results for neutron-production doubledifferential cross sections at 180° for 140-MeV proton incident on carbon, iron, and gold targets, it is concluded that it is necessary to allow a margin for uncertainty caused by the spallation models, which is a factor of two, in estimating the dose rate induced by neutron streaming through a beam duct.

  4. Safety aspects on the Asea-Atom BWR 75 control room design

    International Nuclear Information System (INIS)

    Gemst, Paul van; Pedersen, Tor.

    1978-01-01

    The control room is an integrated part of the total plant layout and is located in a special building, known as the control building. The problems of designing a control room meeting all safety requirements and at the same time allowing for modifications to meet special customer specifications are described. (author)

  5. Nuclear power plant control room ventilation system design for meeting general criterion 19

    International Nuclear Information System (INIS)

    Murphy, K.G.; Campe, K.M.

    1975-01-01

    The requirement for protection of control room personnel against radiation is specified in General Design Criterion 19 of Appendix A, 10 CFR Part 50. The evaluation of a control room design, especially its emergency ventilation system, with respect to radiation protection primarily consists of determining the radiation doses to control room personnel under accident conditions. The accident dose assessment involves modeling and evaluation of radiological source terms, atmospheric transport of airborne activity, and protection features of the control room ventilation system. Some of the assumptions and conservatisms used in the dose analyses are based on the technical review experience of existing or proposed control room designs. A review of over 50 control room designs has revealed a great variety of design concepts, not all of which seem to have been based on radiation protection criteria. A summary of the basic control room protection requirements, design features, dose acceptance criteria, and an outline of the methods used by the Regulatory staff for accident dose evaluation are presented. (U.S.)

  6. Emergency control room design of a nuclear reactor used to produce radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Isaac J.A.L. dos; Farias, Larissa P. de; Ponte, Luana T.L.; Goncalves, Gabriel L.; Castro, Heraclito M.; Farias, Marcos S.; Carvalho, Paulo V.R. de; Vianna Filho, Alfredo M.V., E-mail: luquetti@ien.gov.br [Instituto Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Departamento Engenharia Nuclear

    2015-07-01

    A control room is defined as a functional entity with an associated physical structure, where the operators carry out the centralized control, monitoring and administrative responsibilities. Emergency control room acts as an alternative control room for the purpose of shutting down or maintaining the facility in a safe shutdown state when the main control room is uninhabitable. The mission of emergency control room is to provide the resources to bring the plant to a safe shutdown condition after an evacuation of the main control room. An evacuation of the main control room is assumed when there is no possibility to accomplish tasks involved in the shutdown except reactor trip. The purpose of this paper is to present a specific approach for the design of the emergency control room of a nuclear reactor used to produce radioisotope. The approach is based on human factors standards and the participation of a multidisciplinary team in the development phase of the design. Using the information gathered from standards and from the multidisciplinary team a 3D Sketch and a 3D printing of the emergency control room were created. (author)

  7. Emergency control room design of a nuclear reactor used to produce radioisotope

    International Nuclear Information System (INIS)

    Santos, Isaac J.A.L. dos; Farias, Larissa P. de; Ponte, Luana T.L.; Goncalves, Gabriel L.; Castro, Heraclito M.; Farias, Marcos S.; Carvalho, Paulo V.R. de; Vianna Filho, Alfredo M.V.

    2015-01-01

    A control room is defined as a functional entity with an associated physical structure, where the operators carry out the centralized control, monitoring and administrative responsibilities. Emergency control room acts as an alternative control room for the purpose of shutting down or maintaining the facility in a safe shutdown state when the main control room is uninhabitable. The mission of emergency control room is to provide the resources to bring the plant to a safe shutdown condition after an evacuation of the main control room. An evacuation of the main control room is assumed when there is no possibility to accomplish tasks involved in the shutdown except reactor trip. The purpose of this paper is to present a specific approach for the design of the emergency control room of a nuclear reactor used to produce radioisotope. The approach is based on human factors standards and the participation of a multidisciplinary team in the development phase of the design. Using the information gathered from standards and from the multidisciplinary team a 3D Sketch and a 3D printing of the emergency control room were created. (author)

  8. Human-factors engineering-control-room design review: Shoreham Nuclear Power Station. Draft audit report

    International Nuclear Information System (INIS)

    Peterson, L.R.; Preston-Smith, J.; Savage, J.W.; Rousseau, W.F.

    1981-01-01

    A human factors engineering preliminary design review of the Shoreham control room was performed at the site on March 30 through April 3, 1981. This design review was carried out by a team from the Human Factors Engineering Branch, Division of Human Factors Safety. This report was prepared on the basis of the HFEB's review of the applicant's Preliminary Design Assessment and the human factors engineering design review/audit performed at the site. The presented sections are numbered to conform to the guidelines of the draft version of NUREG-0700. They summarize the teams's observations of the control room design and layout, and of the control room operators' interface with the control room environment

  9. SU-E-T-270: Optimized Shielding Calculations for Medical Linear Accelerators (LINACs).

    Science.gov (United States)

    Muhammad, W; Lee, S; Hussain, A

    2012-06-01

    The purpose of radiation shielding is to reduce the effective equivalent dose from a medical linear accelerator (LINAC) to a point outside the room to a level determined by individual state/international regulations. The study was performed to design LINAC's room for newly planned radiotherapy centers. Optimized shielding calculations were performed for LINACs having maximum photon energy of 20 MV based on NCRP 151. The maximum permissible dose limits were kept 0.04 mSv/week and 0.002 mSv/week for controlled and uncontrolled areas respectively by following ALARA principle. The planned LINAC's room was compared to the already constructed (non-optimized) LINAC's room to evaluate the shielding costs and the other facilities those are directly related to the room design. In the evaluation process it was noted that the non-optimized room size (i.e., 610 × 610 cm 2 or 20 feet × 20 feet) is not suitable for total body irradiation (TBI) although the machine installed inside was having not only the facility of TBI but the license was acquired. By keeping this point in view, the optimized INAC's room size was kept 762 × 762 cm 2. Although, the area of the optimized rooms was greater than the non-planned room (i.e., 762 × 762 cm 2 instead of 610 × 610 cm 2), the shielding cost for the optimized LINAC's rooms was reduced by 15%. When optimized shielding calculations were re-performed for non-optimized shielding room (i.e., keeping room size, occupancy factors, workload etc. same), it was found that the shielding cost may be lower to 41 %. In conclusion, non- optimized LINAC's room can not only put extra financial burden on the hospital but also can cause of some serious issues related to providing health care facilities for patients. © 2012 American Association of Physicists in Medicine.

  10. Population-based metaheuristic optimization in neutron optics and shielding design

    Energy Technology Data Exchange (ETDEWEB)

    DiJulio, D.D., E-mail: Douglas.DiJulio@esss.se [European Spallation Source ERIC, P.O. Box 176, SE-221 00 Lund (Sweden); Division of Nuclear Physics, Lund University, SE-221 00 Lund (Sweden); Björgvinsdóttir, H. [European Spallation Source ERIC, P.O. Box 176, SE-221 00 Lund (Sweden); Department of Physics and Astronomy, Uppsala University, SE-751 20 Uppsala (Sweden); Zendler, C. [European Spallation Source ERIC, P.O. Box 176, SE-221 00 Lund (Sweden); Bentley, P.M. [European Spallation Source ERIC, P.O. Box 176, SE-221 00 Lund (Sweden); Department of Physics and Astronomy, Uppsala University, SE-751 20 Uppsala (Sweden)

    2016-11-01

    Population-based metaheuristic algorithms are powerful tools in the design of neutron scattering instruments and the use of these types of algorithms for this purpose is becoming more and more commonplace. Today there exists a wide range of algorithms to choose from when designing an instrument and it is not always initially clear which may provide the best performance. Furthermore, due to the nature of these types of algorithms, the final solution found for a specific design scenario cannot always be guaranteed to be the global optimum. Therefore, to explore the potential benefits and differences between the varieties of these algorithms available, when applied to such design scenarios, we have carried out a detailed study of some commonly used algorithms. For this purpose, we have developed a new general optimization software package which combines a number of common metaheuristic algorithms within a single user interface and is designed specifically with neutronic calculations in mind. The algorithms included in the software are implementations of Particle-Swarm Optimization (PSO), Differential Evolution (DE), Artificial Bee Colony (ABC), and a Genetic Algorithm (GA). The software has been used to optimize the design of several problems in neutron optics and shielding, coupled with Monte-Carlo simulations, in order to evaluate the performance of the various algorithms. Generally, the performance of the algorithms depended on the specific scenarios, however it was found that DE provided the best average solutions in all scenarios investigated in this work.

  11. Design of a control system for self-shielded irradiators with remote access capability

    International Nuclear Information System (INIS)

    Iyengar, R.D.; Verma, P.B.; Prasad, V.V.S.S.; George, Jain R.; Das, Tripti; Deshmukh, D.K.

    2001-01-01

    With self-shielded irradiators like Gamma chambers, and Blood irradiators are being sold by BRIT to customers both within and outside the country, it has become necessary to improve the quality of service without increasing the overheads. The recent advances in the field of communications and information technology can be exploited for improving the quality of service to the customers. A state of the art control system with remote accessibility has been designed for these irradiators enhancing their performance. This will provide an easy access to these units wherever they might be located, through the Internet. With this technology it will now be possible to attend to the needs of the customers, as regards fault rectification, error debugging, system software update, performance testing, data acquisition etc. This will not only reduce the downtime of these irradiators but also reduce the overheads. (author)

  12. Preliminary shielding analysis in support of the CSNS target station shutter neutron beam stop design

    Institute of Scientific and Technical Information of China (English)

    ZHANG Bin; CHEN Yi-Xue; WANG Wei-Jin; YANG Shou-Hai; WU Jun; YIN Wen; LIANG Tian-Jiao; JIA Xue-Jun

    2011-01-01

    The construction of China Spallation Neutron Source (CSNS) has been initiated in Dongguan,Guangdong, China.Thus a detailed radiation transport analysis of the shutter neutron beam stop is of vital importance. The analyses are performed using the coupled Monte Carlo and multi-dimensional discrete ordinates method. The target of calculations is to optimize the neutron beamline shielding design to guarantee personal safety and minimize cost. Successful elimination of the primary ray effects via the two-dimensional uncollided flux and the first collision source methodology is also illustrated. Two-dimensional dose distribution is calculated. The dose at the end of the neutron beam line is less than 2.5μSv/h. The models have ensured that the doses received by the hall staff members are below the standard limit required.

  13. The ITER thermal shields for the magnet system: Design evolution and analysis

    International Nuclear Information System (INIS)

    Bykov, V.; Krasikov, Yu.; Grigoriev, S.; Komarov, V.; Krylov, V.; Labusov, A.; Pyrjaev, V.; Chiocchio, S.; Smirnov, V.; Sorin, V.; Tanchuk, V.

    2005-01-01

    The thermal shield (TS) system provides the required reduction of thermal loads to the cold structures operating at 4.5 K. This paper presents the rationale for the TS design evolution, details of the recent modifications that affect the TS cooling panels, the central TS ports and support system, interface labyrinths and TS structural joints. The modern results of thermal-hydraulic, thermal, seismic, static and dynamic structural analyses, that involve sub-modeling and sub-structuring finite element analysis techniques, are also reported. The modifications result in considerable reduction of TS mass, surface area and heat loads to/from the TS, simplification of TS assembly procedure and in-cryostat maintenance

  14. Gonadal shield.

    Science.gov (United States)

    Purdy, J A; Stiteler, R D; Glasgow, G P; Mill, W B

    1975-10-01

    A secondary gonadal shield for use in the pelvic irradiation of males was designed and built using material and apparatus available with the Cerrobend blocking system. The gonadal dose was reduced to approximately 1.5 to 2.5% of the given dose.

  15. The development of KNGR control room man-machine interface design

    International Nuclear Information System (INIS)

    Sung-Jae Cho; Yeong-Cheol Shin

    2000-01-01

    KNGR MMI design has been developed for the last 7 years as a part of Korea Next Generation Reactor (KNGR) design development. The KNGR control room has the common features of advanced control room such as large display panel, redundant compact workstations, soft control, and computerized procedure system. A conventional type safety console is provided as a backup when operation at the workstations is impossible. The strong points of an advanced control room are based on the powerful information processing and flexible graphic presentation capability of computer technology. On the other hand, workstation based design has a weak point that the amount of information to be presented in one VDU is limited. This can cause navigational overload and inconsistent interfaces and provide chances for performance errors/failures, if not designed carefully. From this background, the regulators require licensees to follow strict top-down human factor engineering design process. Analysis of operating experiences and iterative evaluations are used to address the potential problems of the KNGR advanced control room MMI design. But, further study is necessary in design area like CPS design, where experiences or design guidance is insufficient. Further study topics for KNGR advanced control room MMI design development are discussed briefly in this paper. (author)

  16. A room for design: Through participatory design young adults with schizophrenia become strong collaborators.

    Science.gov (United States)

    Terp, Malene; Laursen, Birgitte Schantz; Jørgensen, Rikke; Mainz, Jan; Bjørnes, Charlotte D

    2016-12-01

    Smartphone technology is being increasingly viewed as key to engaging young adults with schizophrenia in their own mental health care. In an attempt to use smartphones as an engagement tool, we conducted a participatory design process, where young adults with schizophrenia (n = 4), healthcare providers (n = 7), software designers (n = 3), graphic designer (n = 1), graphic recorder (n = 1), and team leader (n = 1) co-designed a smartphone application for use in early phase schizophrenia care. This paper reports the co-design process. Based on a variety of written data-sources, the paper describes if, and how, participatory design can help construct a physical and relational environment that enables young adults with schizophrenia to become active participants in the design of a more participatory mental health practice. Guided by Etienne Wenger's construct of Community of Practice, three major categories of characteristics and construction of a physical and relational environment supporting and inspiring participation and engagement were identified: (i) a pre-narrative about a community of practice, (ii) the room for design is a community of practice and (iii) the community of practice as a practice of special qualities. It is concluded that participatory design can support and inspire participation and engagement in the development of mental health care with young adults with schizophrenia, given that the environment in which participatory design unfolds is transparent, flexible, secure and informal. © 2016 Australian College of Mental Health Nurses Inc.

  17. Survey of control-room design practices with respect to human factors engineering

    International Nuclear Information System (INIS)

    Seminara, J.L.; Parsons, S.O.

    1980-01-01

    Human factors engineering is an interdisciplinary speciality concerned with influencing the design of equipment systems, facilities, and operational environments to promote safe, efficient, and reliable operator performance. This emphasis has been applied to most military and space systems in the past 30 y. A review of five nuclear power-plant control rooms, reported in the November-December 1977 issue of Nuclear Safety, revealed that human factors principles of design have generally not been incorporated in present-generation control rooms. This article summarizes the findings of a survey of 20 control-board designers from a mix of nuclear steam-supply system and architect-engineering firms. The interviews with these designers probed design methods currently used in developing control rooms. From these data it was concluded that there is currently no consistent, formal, uniform concern for the human factors aspects of control-room design on the part of the design organizations, the utilities, or the Nuclear Regulatory Commission. Although all the parties involved are concerned with human factors issues, this responsibility is not focused, and human factors yardsticks, or design standards, specific to power plants have not been evolved and applied in the development and verification of control-room designs from the standpoint of the man-machine interface

  18. SU-E-T-243: Design of a Novel Testing Port for Radiation Protection and Shielding Measurements

    International Nuclear Information System (INIS)

    Tanny, S; Parsai, E; Harrell, D; Noller, J; Chopra, M

    2015-01-01

    Purpose: The majority of radiation shielding research utilizes Monte Carlo simulation because of the difficulty in eliminating secondary radiations from measurements. We have designed a test port into a primary barrier of our newest vault to allow for shielding measurements while ensuring adequate protection to the public and staff during normal machine operation. This port allows for measurement of attenuation values of shielding materials, differential dose albedos, and radiation scatter fractions. Methods: The vault design utilized the maze as part of a compound primary barrier. The test port is contained within the maze and is centered along isocenter. The inner 30 cm has a 20×20 cm 2 opening, while the remaining length has a 30×30 cm 2 opening. The block that contains the port has a density of 200 pcf to minimize internal scatter. The 30×30 cm 2 opening is occupied by removable 215 pcf concrete blocks. The innermost and outermost blocks activate an interlock wired into the beam-enable loop. This disallows beam-on in treatment mode if the interlock isn’t closed. The interlock can be overridden in service mode, or by-passed via an override switch in case of circuit failure. Results: The test port was installed in August. The beam is disabled when the interlock is tripped. Measurements taken when the primary beam is not incident on the port are indistinguishable from background. Ambient dose levels surrounding the vault with the designed shielding blocks in place are all within allowable limits for occupational workers. Conclusions: We have designed and installed a unique testing port for radiation protection and shielding measurements. This port is appropriately interlocked and designed to mitigate any risks of incidental exposure to staff or members of the public. The test port design allows measurements with “good geometry” and efficient removal of contaminating sources of radiation present in many shielding measurements. Daniel Harrell and Jim Noller

  19. Optimal color design of psychological counseling room by design of experiments and response surface methodology.

    Science.gov (United States)

    Liu, Wenjuan; Ji, Jianlin; Chen, Hua; Ye, Chenyu

    2014-01-01

    Color is one of the most powerful aspects of a psychological counseling environment. Little scientific research has been conducted on color design and much of the existing literature is based on observational studies. Using design of experiments and response surface methodology, this paper proposes an optimal color design approach for transforming patients' perception into color elements. Six indices, pleasant-unpleasant, interesting-uninteresting, exciting-boring, relaxing-distressing, safe-fearful, and active-inactive, were used to assess patients' impression. A total of 75 patients participated, including 42 for Experiment 1 and 33 for Experiment 2. 27 representative color samples were designed in Experiment 1, and the color sample (L = 75, a = 0, b = -60) was the most preferred one. In Experiment 2, this color sample was set as the 'central point', and three color attributes were optimized to maximize the patients' satisfaction. The experimental results show that the proposed method can get the optimal solution for color design of a counseling room.

  20. Is function-based control room design human-centered?

    International Nuclear Information System (INIS)

    Norros, L.; Savioja, P.

    2006-01-01

    Function-based approaches to system interface design appears an appealing possibility in helping designers and operators to cope with the vast amount of information needed to control complex processes. In this paper we provide evidence of operator performance analyses showing that outcome-centered performance measures may not be sufficiently informative for design. We need analyses indicating habitual patterns of using information, operator practices. We argue that practices that portray functional orienting to the task support mastery of the process. They also create potential to make use of function-based information presentation. We see that functional design is not an absolute value. Instead, such design should support communication of the functional significance of the process information to the operators in variable situations. Hence, it should facilitate development of practices that focus to interpreting this message. Successful function-based design facilitates putting operations into their contexts and is human-centered in an extended sense: It aids making sense in the complex, dynamic and uncertain environment. (authors)

  1. An evaluation of NCRP report 151--radiation shielding design for radiotherapy facilities, and a feasibility study for 6 MV open-door treatments in an existing high-energy radiation therapy bunker

    Science.gov (United States)

    Kildea, John

    This thesis describes a study of shielding design techniques used for radiation therapy facilities that employ megavoltage linear accelerators. Specifically, an evaluation of the shielding design formalism described in NCRP report 151 was undertaken and a feasibility study for open-door 6 MV radiation therapy treatments in existing 6 MV, 18 MV treatment rooms at the Montreal General Hospital (MGH) was conducted. To evaluate the shielding design formalism of NCRP 151, barrier-attenuated equivalent doses were measured for several of the treatment rooms at the MGH and compared with expectations from NCRP 151 calculations. It was found that, while the insight and recommendations of NCRP 151 are very valuable, its dose predictions are not always correct. As such, the NCRP 151 methodology is best used in conjunction with physical measurements. The feasibility study for 6 MV open-door treatments made use of the NCRP 151 formalism, together with physical measurements for realistic 6 MV workloads. The results suggest that, dosimetrically, 6 MV open door treatments are feasible. A conservative estimate for the increased dose at the door arising from such treatments is 0.1 mSv, with a 1/8 occupancy factor, as recommended in NCRP 151, included.

  2. Multi-objective optimization of a compact pressurized water nuclear reactor computational model for biological shielding design using innovative materials

    Energy Technology Data Exchange (ETDEWEB)

    Tunes, M.A., E-mail: matheus.tunes@usp.br [Department of Metallurgical and Materials Engineering, Escola Politécnica da Universidade de São Paulo, Av. Prof. Mello Moraes, 2463 – CEP 05508 – 030 São Paulo (Brazil); Oliveira, C.R.E. de, E-mail: cassiano@unm.edu [Department of Nuclear Engineering, The University of New Mexico, Farris Engineering Center, 221, Albuquerque, NM 87131-1070 (United States); Schön, C.G., E-mail: schoen@usp.br [Department of Metallurgical and Materials Engineering, Escola Politécnica da Universidade de São Paulo, Av. Prof. Mello Moraes, 2463 – CEP 05508 – 030 São Paulo (Brazil)

    2017-03-15

    Highlights: • Use of two n-γ transport codes leads to optimized model of compact nuclear reactor. • It was possible to safely reduce both weight and volume of the biological shielding. • Best configuration obtained by using new composites for both γ and n attenuation. - Abstract: The aim of the present work is to develop a computational model of a compact pressurized water nuclear reactor (PWR) to investigate the use of innovative materials to enhance the biological shielding effectiveness. Two radiation transport codes were used: the first one – MCNP – for the PWR design and the GEM/EVENT to simulate (in a 1D slab) the behavior of several materials and shielding thickness on gamma and neutron radiation. Additionally MATLAB Optimization Toolbox was used to provide new geometric configurations of the slab aiming at reducing the volume and weight of the walls by means of a cost/objective function. It is demonstrated in the reactor model that the dose rate outside biological shielding has been reduced by one order of magnitude for the optimized model compared with the initial configuration. Volume and weight of the shielding walls were also reduced. The results indicated that one-dimensional deterministic code to reach an optimized geometry and test materials, combined with a three-dimensional model of a compact nuclear reactor in a stochastic code, is a fast and efficient procedure to test shielding performance and optimization before the experimental assessment. A major outcome of this research is that composite materials (ECOMASS 2150TU96) may replace (with advantages) traditional shielding materials without jeopardizing the nuclear power plant safety assurance.

  3. Shield design and streaming calculations for the sodium cooled PEC reactor

    International Nuclear Information System (INIS)

    Prosperi, M.; Tavoni, R.; Travaglini, N.

    1977-01-01

    This paper summarises the shielding calculations carried out for the PEC reactor. A brief description of calculation methods and of the work carried out to set them up is given; the most representative calculations with the relative isoflux curves are also referred. A general outline is then given for the main shielding problems of the PEC reactor

  4. Survey of shielding calculation parameters in radiotherapy rooms used in the country and its impact in the existing calculation methodologies; Levantamento de parametros de calculos de blindagem de salas de radioterapia utilizados no pais e seu impacto nas metodologias de calculo existentes

    Energy Technology Data Exchange (ETDEWEB)

    Japiassu, Fernando Parois

    2013-07-01

    When designing radiotherapy treatment rooms, the dimensions of barriers are established on the basis of American calculation methodologies specifically; NCRP Report N° 49, NCRP Report N° 51, and more recently, NCRP Report N° 151. Such barrier calculations are based on parameters reflecting predictions of treatments to be performed within the room; which, in tum, reftect a specific reality found in a country. There exists, however, a variety of modern radiotherapy techniques, such as Intensity Modulated Radiation Therapy (IMRT); Total Body Irradiation (TBl) and radiosurgery (SRS); where patierits are treated in a much different way than during more conventional treatrnents, which are not taken into account the traditional shielding calculation methodology. This may lead to a faulty design of treattnent rooms. In order to establish a comparison between the methodology used to calculate shielding design and the reality of treatments performed in Brazil, two radiotherapy facilitie were selected, both of them offering traditional and modern treatment techniqued as described above. Data in relation with reatments perfotmed over a period of six (6)months of operations in both institutions were collected. Based on tlis informaton, a new set of realistic parameters required for shielding design was estãblished, whicb in turn allowed for a nwe caculation of barrier thickness for both facilities. The barrier thickness resultaing from this calculation was then compared with the barrier thickness propose as part of the original shielding design, approved by the regulatory authority. First, concerning the public facility, the thickness of all primary barriers proposed in the shielding design was actually larger than the thickness resulting from calculations based on realistic parameters. Second, concerning the private facility, the new data show that the thickness of three out of the four primary barriers described in the project is larger than the thickness oresulting from

  5. Implementation and display of Computer Aided Design (CAD) models in Monte Carlo radiation transport and shielding applications

    International Nuclear Information System (INIS)

    Burns, T.J.

    1994-01-01

    An Xwindow application capable of importing geometric information directly from two Computer Aided Design (CAD) based formats for use in radiation transport and shielding analyses is being developed at ORNL. The application permits the user to graphically view the geometric models imported from the two formats for verification and debugging. Previous models, specifically formatted for the radiation transport and shielding codes can also be imported. Required extensions to the existing combinatorial geometry analysis routines are discussed. Examples illustrating the various options and features which will be implemented in the application are presented. The use of the application as a visualization tool for the output of the radiation transport codes is also discussed

  6. Shielding designs and tests of a new exclusive ship for transporting spent nuclear fuels

    International Nuclear Information System (INIS)

    Ono, M.; Ito, D.; Kitano, T.; Ueki, K.; Akiyama, H.; Obara, I.; Sanui, T.

    2000-01-01

    The Rokuei-Maru, a ship built specially for the transport of spent nuclear fuels in casks, was launched April in 1996. She is the first ship to comply with special Japanese regulations, KAISA 520, based on the INF code. DOT3.5 and MCNP-4A were used for the evaluation of dose equivalent rates of her shielding structures. On-board gamma-ray shielding tests were executed to confirm the effectiveness of the ship's shielding performance. The tests confirmed that effective shielding has been achieved and the dose equivalent rate in the accommodation and other inhabited spaces is sufficiently lower than the regulated limitations. This was achieved by employing the appropriate calculation methods and shielding materials. (author)

  7. Experience in the review of utility control room design review and safety parameter display system programs

    International Nuclear Information System (INIS)

    Moore, V.A.

    1985-01-01

    The Detailed Control Room Design Review (DCRDR) and the Safety Parameter Display System (SPDS) had their origins in the studies and investigations conducted as the result of the TMI-2 accident. The President's Commission (Kemeny Commission) critized NRC for not examining the man-machine interface, over-emphasizing equipment, ignoring human beings, and tolerating outdated technology in control rooms. The Commission's Special Inquiry Group (Rogovin Report) recommended greater application of human factors engineering including better instrumentation displays and improved control room design. The NRC Lessons Learned Task Force concluded that licensees should review and improve control rooms using NRC Human engineering guidelines, and install safety parameter display systems (then called the safety staff vector). The TMI Action Plan Item I.D.1 and I.D.2 were based on these recommendations

  8. Control room design of a nuclear reactor used to produce radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Isaac Jose Antonio Luquetti dos; Carvalho, Paulo Vitor R.; Lacerda, Fabio de; Szabo, Andre P.; Vianna Filho, Alfredo Marques, E-mail: luquetti@ien.gov.br [Instituto Engenharia Nuclear (IEN/CNEN-RJ), Rio Janeiro, RJ (Brazil). Divisao de Instrumentacao e Confiabilidade Humana; Falcao, Mariana A. [Escola de Belas Artes da Universidade Federal do Rio de Janeiro, RJ (Brazil)

    2011-07-01

    A control room is defined as a functional entity with an associated physical structure, where the operators carry out the centralized control, monitoring and administrative responsibilities. Inadequate integration between control room and operators reduces safety, increases the operation complexity, complicates operator training and increases the likelihood of human errors occurrence. The purpose of this paper is to present a specific approach for the design of the main control room of a nuclear reactor used to produce radioisotope. The approach is based on human factors standards and the participation of a multidisciplinary team in the conceptual and basic phases of the design. Using the information gathered from standards and from the multidisciplinary an initial sketch 3D of the main control room is being developed. (author)

  9. Control room design of a nuclear reactor used to produce radioisotope

    International Nuclear Information System (INIS)

    Santos, Isaac Jose Antonio Luquetti dos; Carvalho, Paulo Vitor R.; Lacerda, Fabio de; Szabo, Andre P.; Vianna Filho, Alfredo Marques

    2011-01-01

    A control room is defined as a functional entity with an associated physical structure, where the operators carry out the centralized control, monitoring and administrative responsibilities. Inadequate integration between control room and operators reduces safety, increases the operation complexity, complicates operator training and increases the likelihood of human errors occurrence. The purpose of this paper is to present a specific approach for the design of the main control room of a nuclear reactor used to produce radioisotope. The approach is based on human factors standards and the participation of a multidisciplinary team in the conceptual and basic phases of the design. Using the information gathered from standards and from the multidisciplinary an initial sketch 3D of the main control room is being developed. (author)

  10. Re-evaluation of structural shielding designs of X-ray and CO-60 gamma-ray scanners at the Port of Tema, Ghana

    International Nuclear Information System (INIS)

    Ofori, K.

    2011-07-01

    This research work was conducted to re-evaluate the shielding designs of the 6 MeV x-ray and the 1.253 MeV Co-60 gamma ray scanners used for cargo-containerized scanning at the Port of Tema. These scanners utilize ionizing radiation, therefore adequate shielding must be provided to reduce the radiation exposure of persons in and around the facilities to acceptable levels. The purpose of radiation shielding is to protect workers and the general public from the harmful effects of ionizing radiation. Investigations on the facilities indicated that after commissioning, no work had been carried out to re-evaluate the shielding designs. However, workloads have increased over time neccessitating review of the installed shielding. There has been introduction of scanner units with higher radiation energy (as in the case of the x-ray scanner) posibily increasing dose rates at various location requiring review of the shielding. New structures have been dotted around the facilities without particular attention to their distances and locations with respect to the radiation source. Measurements of distances from the source axes to the points of concern for primary and leakage barrier shielding; source to container and container to the points of concern for scattered radiation shielding were taken. The primary and secondary thicknesses required for both scanners were determined based on current operational parameters and compared with the thickness constituted during the construction of the facilities. Calculated and measured dose rate beyond the shielding barriers were used to established the adequacy or otherwise of the shielding employed by the shielding designers. Values obtained fell below the 20 µSv/hr specified by NCRP 151 (2005) which showed that the primary and secondary shields of both facilities were adequate requiring no additional shielding. (author)

  11. The evaluation the magnitude radiation exposure dose rate in digital radiography room design

    Science.gov (United States)

    Dwiyanto, Agung; Setia Budi, Wahyu; Hardiman, Gagoek

    2017-12-01

    This study discusses the dose rate in digital radiography room, buit according to meet the provisions of KEMENKES No.1014 / Menkes / SK / XI / 2008 and Regulation of BAPETEN No. 8 / 2011. The provisions primary concern of radiation safety, not comfort, by considering the space design. There are five aspects to consider in designing the space: functionality, comfort, security, movement activities and aesthetics. However provisions only met three aspects of the design, which are a function, security and movement activity. Therefore, it is necessary to evaluate digital radiography room in terms of its ability to control external radiation exposure to be safe and comfortable The dose rate is measured by the range of primary and secondary radiation in the observation points by using Surveymeter. All data are obtained by the preliminary survey prior to the study. Furthermore, the review of digital radiography room is done based on architectural design theory. The dose rate for recommended improvement room is recalculated using the same method as the actual room with the help of computer modeling. The result of dose rate calculation at the inner and outer part of digital radiography observation room shows that in-room dose for a week at each measuring point exceeds the allowable dose limit both for staff and public. During a week of observation, the outdoor dose at some measuring points exceeds the dose limit set by the KEMENKES No.1014 / Menkes / SK / XI / 2008 and Regulation BEPETEN No 8/2011. Meanwhile, the result of dose rate calculation in the inner and outer part of the improved digital radiography room can meet the applicable regulations better.

  12. Human Factors Guidance for Control Room and Digital Human-System Interface Design and Modification, Guidelines for Planning, Specification, Design, Licensing, Implementation, Training, Operation and Maintenance

    Energy Technology Data Exchange (ETDEWEB)

    R. Fink, D. Hill, J. O' Hara

    2004-11-30

    Nuclear plant operators face a significant challenge designing and modifying control rooms. This report provides guidance on planning, designing, implementing and operating modernized control rooms and digital human-system interfaces.

  13. Human Factors Guidance for Control Room and Digital Human-System Interface Design and Modification. Guidelines for Planning, Specification, Design, Licensing, Implementation, Training, Operation and Maintenance

    International Nuclear Information System (INIS)

    Fink, R.; Hill, D.; O'Hara, J.

    2004-01-01

    Nuclear plant operators face a significant challenge designing and modifying control rooms. This report provides guidance on planning, designing, implementing and operating modernized control rooms and digital human-system interfaces

  14. Ergonomic design in the operating room: information technologies

    Science.gov (United States)

    Morita, Mark M.; Ratib, Osman

    2005-04-01

    The ergonomic design in the Surgical OR of information technology systems has been and continues to be a large problem. Numerous disparate information systems with unique hardware and display configurations create an environment similar to the chaotic environments of air traffic control. Patient information systems tend to show all available statistics making it difficult to isolate the key, relevant vitals for the patient. Interactions in this sterile environment are still being done with the traditional keyboard and mouse designed for cubicle office workflows. This presentation will address the shortcomings of the current design paradigm in the Surgical OR that relate to Information Technology systems. It will offer a perspective that addresses the ergonomic deficiencies and predicts how future technological innovations will integrate into this vision. Part of this vision includes a Surgical OR PACS prototype, developed by GE Healthcare Technologies, that addresses ergonomic challenges of PACS in the OR that include lack of portability, sterile field integrity, and UI targeted for diagnostic radiologists. GWindows (gesture control) developed by Microsoft Research and Voice command will allow for the surgeons to navigate and review diagnostic imagery without using the conventional keyboard and mouse that disrupt the integrity of the sterile field. This prototype also demonstrates how a wireless, battery powered, self contained mobile PACS workstation can be optimally positioned for a surgeon to reference images during an intervention as opposed to the current pre-operative review. Lessons learned from the creation of the Surgical OR PACS Prototype have demonstrated that PACS alone is not the end all solution in the OR. Integration of other disparate information systems and presentation of this information in simple, easy to navigate information packets will enable smoother interactions for the surgeons and other healthcare professionals in the OR. More intuitive

  15. Optimizing the human engineering design of control panels in nuclear power plant control rooms

    International Nuclear Information System (INIS)

    Behrendt, V.; Krehbiehl, T.; Hartfiel, H.D.; Mannhaupt, H.R.

    1986-12-01

    The study contains two parts. In the first part an analytical procedure is developed to logically and reproducibly subdivide the control room personnel tasks resulting in a list of the elements (operations) and the structure (operations scheme) of a task. The second part lists together all knowledge of and influences on human engineering which are known at this time and which should be taken into account in designing control rooms. The content of this catalogue can best be used and presented by using a personal computer. Two fundamental different ways are possible to use the catalogue. Designing new control rooms or new parts of control rooms the results of the task analysis which should be done first, should guide the search in the catalogue to find the right human engineering factors. For assessing existing control room panels the performance shaping factors which are establishing the table of content, permit a quick access to the catalogue. Both the specific procedure of the task analysis and the different ways of access to the catalogue of human engineering knowledge for designing nuclear power plant control rooms have been proven by experienced system engineers and safety experts. The results are presented. They have been considered in this version of the study. (orig.) [de

  16. Design of a Control Room for Jordan Research and Training Reactor (JRTR)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Jun; Suh, Sang Moon; Lee, Hyun Chul; Park, Je Yun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    Since the main role of JRTR(Jordan Research and Training Reactor) operating personnel is safe and reliable operation of the reactor, MCR(Main Control Room) and SCR(Supplementary Control Room) must provide them with sufficient information and controls needed to optimize their performance. Before the TMI accident, control room were generally designed just with intuitive common sense, without using any proper HFE(human factors engineering) practices. Many results derived from the analysis of TMI accident showed that a more comprehensive and systematic approaches to develop MCR design requirements were needed. Moreover changes of operators' role as a decision maker from a physical controller in rapid improvement of control system which resulted in higher automation clearly needed more featured regulatory requirements and guidelines. So many regulatory and industrial guidance for control room design have been developed by relevant institution and regulatory bodies. In this paper, a conceptual design of the JRTR control room in the effort of satisfying current regulatory requirements and guidelines are presented. And some information display design is also presented

  17. Evaluation of some resonance self-shielding procedures employed in high conversion light water reactor design

    International Nuclear Information System (INIS)

    Patino, N.E.; Abbate, M.J.; Sbaffoni, M.M.

    1990-01-01

    The procedures employed in the treatment of the resonance shielding effect have been identified as one of the causes of the large discrepancies found in the neutronic calculation of high conversion light water reactors (HCLWRs), indicating the need for a revision of the self-shielding procedures employed. In this work some well known techniques applied in HCLWR self-shielding calculations are evaluated; the study involves the comparison of methods for the generation of group constants, the analysis of the impact of considering some isotopes as infinitely diluted and the evaluation of the usual approximations utilized for the treatment of heterogeneities

  18. Acoustical Design Guidelines for Living Rooms for Adults with intellectual Disabilities

    NARCIS (Netherlands)

    Saher, K.

    2013-01-01

    The aim of this thesis is to investigate the effects of building design tools on acoustical quality parameters in living rooms for adults with intellectual disabilities (ID) and develop acoustical design guidelines for architects. This study is specifically concerned with the validation of

  19. The Urban Decision Room : A multi actor design engineering simulation system

    NARCIS (Netherlands)

    Van Loon, P.P.J.; Barendse, P.; Duerink, S.

    2012-01-01

    This paper deals with the definition and construction of a decision based multi actor urban design model which enables the integration of the allocation of a variety of urban land uses with the distribution of different urban functions: the Urban Decision Room. Urban design (and planning) is, among

  20. Design calculations for a xenon plasma x-ray shield to protect the NIF optical Thomson scattering diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Swadling, G. F.; Ross, J. S.; Datte, P.; Moody, J.; Divol, L.; Jones, O.; Landen, O. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2016-11-15

    An Optical Thomson Scattering (OTS) diagnostic is currently being developed for the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. This diagnostic is designed to make measurements of the hohlraum plasma parameters, such as the electron temperature and the density, during inertial confinement fusion (ICF) experiments. NIF ICF experiments present a very challenging environment for optical measurements; by their very nature, hohlraums produce intense soft x-ray emission, which can cause “blanking” (radiation induced opacity) of the radiation facing optical components. The soft x-ray fluence at the surface of the OTS blast shield, 60 cm from the hohlraum, is estimated to be ∼8 J cm{sup −2}. This is significantly above the expected threshold for the onset of “blanking” effects. A novel xenon plasma x-ray shield is proposed to protect the blast shield from x-rays and mitigate “blanking.” Estimates suggest that an areal density of 10{sup 19} cm{sup −2} Xe atoms will be sufficient to absorb 99.5% of the soft x-ray flux. Two potential designs for this shield are presented.

  1. Critical Design Review of a Powder HIPed Shield Concept. Final Report for the contract EFDA/01-601

    International Nuclear Information System (INIS)

    Lind, Anders

    2002-05-01

    The Shield of the ITER Primary Wall Module Option A consists of a 316L Stainless Steel block with front and back side radially cooled through water headers. In order to avoid structural welds located in high irradiation fields or highly mechanically loaded, powder HIPing was proposed by the EU Home Team as a possible fabrication method. This choice was motivated by the good results obtained through an extensive R and D programme performed within Associations and Industries. However, this fabrication technique has some implications on the design of the component, which shall be considered from the very beginning to achieve good performance and low cost. A critical review was therefore needed to optimise the concept before the fabrication of a Shield prototype. The contractor, based on its own experience on powder HIP technology and on the support from appropriate industry, did check the fabrication feasibility of the proposed Shield concept. The concept was judged to be feasible to a combined powder/solid HIPing route. Some adjustments of the design were proposed. The price for producing one shield block in a series of 400 items was estimated to fall into the range 150,000 - 175,000 Euro/pc

  2. Criticality safety and shielding design issues in the development of a high-capacity cask for truck transport

    International Nuclear Information System (INIS)

    Boshoven, J.K.

    1992-01-01

    General Atomics (GA) will be submitting an application for certification to the US Nuclear Regulatory Commission (NRC) for the GA-4 and GA-9 Casks In 1992. The GA-4 and GA-9 Casks are high-capacity legal weight truck casks designed to transport light water reactor spent fuel assemblies. To maintain a capacity of four pressurized-water-reactor (PWR) spent fuel assemblies, the GA-4 Cask uses burnup credit as part of the criticality control for initial enrichments over 3.0 wt% U-235. Using the US Department of Energy (DOE) Burnup Credit Program as a basis, GA has performed burnup credit analysis which is included in the Safety Analysis Report for Packaging (SARP). The GA-9 Cask can meet the criticality safety requirements using the ''fresh fuel'' assumption. Our approach to shielding design is to optimize the GA-4 and GA-9 Cask shielding configurations for minimum weights and maximum payloads. This optimization involves the use of the most effective shielding material, square cross-section geometry with rounded corners and tapered neutron shielding sections in the non-fuel regions

  3. Design calculations for a xenon plasma x-ray shield to protect the NIF optical Thomson scattering diagnostic.

    Science.gov (United States)

    Swadling, G F; Ross, J S; Datte, P; Moody, J; Divol, L; Jones, O; Landen, O

    2016-11-01

    An Optical Thomson Scattering (OTS) diagnostic is currently being developed for the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. This diagnostic is designed to make measurements of the hohlraum plasma parameters, such as the electron temperature and the density, during inertial confinement fusion (ICF) experiments. NIF ICF experiments present a very challenging environment for optical measurements; by their very nature, hohlraums produce intense soft x-ray emission, which can cause "blanking" (radiation induced opacity) of the radiation facing optical components. The soft x-ray fluence at the surface of the OTS blast shield, 60 cm from the hohlraum, is estimated to be ∼8 J cm -2 . This is significantly above the expected threshold for the onset of "blanking" effects. A novel xenon plasma x-ray shield is proposed to protect the blast shield from x-rays and mitigate "blanking." Estimates suggest that an areal density of 10 19 cm -2 Xe atoms will be sufficient to absorb 99.5% of the soft x-ray flux. Two potential designs for this shield are presented.

  4. Design of vessel baking system and thermal radiation shields for SST-1

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, E.R.; Nagabhushana, S.; Pathak, H.A.; Panigrahi, S.; Nath, T.R.; Babu, A.V.S; Gangradey, R.; Patel, R.J.; Saxena, Y.C. [Institute for Plasma Research, Gandhinagar (India)

    1998-07-01

    SST-1 is a Steady State Tokamak with a major radius of 1.1 m, minor radius of 0.2 m and toroidal field of 3.0 T. The toroidal and poloidal field coils of SST-1 are superconducting. One of the main objectives of SST-1 is to demonstrate steady state particle removal and active plasma density control which states the necessity of wall conditioning. The vacuum vessel will be baked up to 525 K by passing hot nitrogen gas through the U - channels welded on the inner surface of vacuum vessel. The required mass flow rate at 5 bar is 0.712 Kg/s to maintain 525 K wall temperature in steady state. Superconducting coils operating at 4.5 K will be protected against thermal radiation from hot surfaces using liquid nitrogen cooled panels operating at 87 K. Maximum 1200 litres/hour liquid nitrogen is required during vessel baking. The design of vacuum vessel baking system and thermal radiation shields and related flow analysis are presented here. (authors)

  5. Design of vessel baking system and thermal radiation shields for SST-1

    International Nuclear Information System (INIS)

    Kumar, E.R.; Nagabhushana, S.; Pathak, H.A.; Panigrahi, S.; Nath, T.R.; Babu, A.V.S; Gangradey, R.; Patel, R.J.; Saxena, Y.C.

    1998-01-01

    SST-1 is a Steady State Tokamak with a major radius of 1.1 m, minor radius of 0.2 m and toroidal field of 3.0 T. The toroidal and poloidal field coils of SST-1 are superconducting. One of the main objectives of SST-1 is to demonstrate steady state particle removal and active plasma density control which states the necessity of wall conditioning. The vacuum vessel will be baked up to 525 K by passing hot nitrogen gas through the U - channels welded on the inner surface of vacuum vessel. The required mass flow rate at 5 bar is 0.712 Kg/s to maintain 525 K wall temperature in steady state. Superconducting coils operating at 4.5 K will be protected against thermal radiation from hot surfaces using liquid nitrogen cooled panels operating at 87 K. Maximum 1200 litres/hour liquid nitrogen is required during vessel baking. The design of vacuum vessel baking system and thermal radiation shields and related flow analysis are presented here. (authors)

  6. Design of a management information system for the Shielding Experimental Reactor ageing management

    International Nuclear Information System (INIS)

    He Jie; Xu Xianhong

    2010-01-01

    The problem of nuclear reactor ageing is a topic of increasing importance in nuclear safety recent years. Ageing management is usually implemented for reactors maintenance. In the practice, a large number of data and records need to be processed. However, there are few professional software applications that aid reactor ageing management, especially for research reactors. This paper introduces the design of a new web-based management information system (MIS), named the Shielding Experimental Reactor Ageing Management Information System (SERAMIS). It is an auxiliary means that helps to collect data, keep records, and retrieve information for a research reactor ageing management. The Java2 Enterprise Edition (J2EE) and network database techniques, such as three-tiered model, Model-View-Controller architecture, transaction-oriented operations, and JavaScript techniques, are used in the development of this system. The functionalities of the application cover periodic safety review (PSR), regulatory references, data inspection, and SSCs classification according to ageing management methodology. Data and examples are presented to demonstrate the functionalities. For future work, techniques of data mining will be employed to support decision-making.

  7. Analysis of a shield design for a DT neutron generator test facility.

    Science.gov (United States)

    Chichester, D L; Pierce, G D

    2007-10-01

    Independent numerical simulations have been performed using the MCNP5 and SCALE5 radiation transport codes to evaluate the effectiveness of a concrete facility designed to shield personnel from neutron radiation emitted from DT neutron generators. The analysis considered radiation source terms of 14.1 MeV monoenergetic neutrons located at three discrete locations within the two test vaults in the facility, calculating neutron and photon dose rates at 44 locations around the facility using both codes. In addition, dose rate contours were established throughout the facility using the MCNP5 mesh tally feature. Neutron dose rates calculated outside of the facility are predicted to be below 0.01 mrem/h at all locations when all neutron generator source terms are operating within the facility. Similarly, the neutron dose rate in one empty test vault when the adjacent test vault is being utilized is also less then 0.01 mrem/h. For most calculation locations outside the facility the photon dose rates were less then the neutron dose rates by a factor of 10 or more.

  8. Design of a management information system for the Shielding Experimental Reactor ageing management

    Energy Technology Data Exchange (ETDEWEB)

    He Jie, E-mail: hejiejoe@163.co [Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China); Xu Xianhong [Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China)

    2010-01-15

    The problem of nuclear reactor ageing is a topic of increasing importance in nuclear safety recent years. Ageing management is usually implemented for reactors maintenance. In the practice, a large number of data and records need to be processed. However, there are few professional software applications that aid reactor ageing management, especially for research reactors. This paper introduces the design of a new web-based management information system (MIS), named the Shielding Experimental Reactor Ageing Management Information System (SERAMIS). It is an auxiliary means that helps to collect data, keep records, and retrieve information for a research reactor ageing management. The Java2 Enterprise Edition (J2EE) and network database techniques, such as three-tiered model, Model-View-Controller architecture, transaction-oriented operations, and JavaScript techniques, are used in the development of this system. The functionalities of the application cover periodic safety review (PSR), regulatory references, data inspection, and SSCs classification according to ageing management methodology. Data and examples are presented to demonstrate the functionalities. For future work, techniques of data mining will be employed to support decision-making.

  9. Man-machine considerations in nuclear power plant control room design

    International Nuclear Information System (INIS)

    Tennant, D.V.

    1987-01-01

    Although human factors is a subject that has been around for a number of years, this area of design has only recently become known to the power industry. As power plants have grown in size and complexity, the instrumentation required to control and monitor plant processes has increased tremendously. This has been especially true in nuclear power facilities. Although operators are better trained and qualified, very little consideration has been devoted to man-machine interface and the limitations of human operators. This paper explores the historic aspects and design philosophy associated with nuclear plant control rooms. Current problems and solutions are explored along with the components of a control room review. Finally, a survey of future advances in control room design are offered. This paper is concerned with instrumentation, controls, and displays

  10. Designing EvoRoom: An Immersive Simulation Environment for Collective Inquiry in Secondary Science

    Science.gov (United States)

    Lui, Michelle Mei Yee

    This dissertation investigates the design of complex inquiry for co-located students to work as a knowledge community within a mixed-reality learning environment. It presents the design of an immersive simulation called EvoRoom and corresponding collective inquiry activities that allow students to explore concepts around topics of evolution and biodiversity in a Grade 11 Biology course. EvoRoom is a room-sized simulation of a rainforest, modeled after Borneo in Southeast Asia, where several projected displays are stitched together to form a large, animated simulation on each opposing wall of the room. This serves to create an immersive environment in which students work collaboratively as individuals, in small groups and a collective community to investigate science topics using the simulations as an evidentiary base. Researchers and a secondary science teacher co-designed a multi-week curriculum that prepared students with preliminary ideas and expertise, then provided them with guided activities within EvoRoom, supported by tablet-based software as well as larger visualizations of their collective progress. Designs encompassed the broader curriculum, as well as all EvoRoom materials (e.g., projected displays, student tablet interfaces, collective visualizations) and activity sequences. This thesis describes a series of three designs that were developed and enacted iteratively over two and a half years, presenting key features that enhanced students' experiences within the immersive environment, their interactions with peers, and their inquiry outcomes. Primary research questions are concerned with the nature of effective design for such activities and environments, and the kinds of interactions that are seen at the individual, collaborative and whole-class levels. The findings fall under one of three themes: 1) the physicality of the room, 2) the pedagogical script for student observation and reflection and collaboration, and 3) ways of including collective

  11. Shielding benchmark problems, (2)

    International Nuclear Information System (INIS)

    Tanaka, Shun-ichi; Sasamoto, Nobuo; Oka, Yoshiaki; Shin, Kazuo; Tada, Keiko.

    1980-02-01

    Shielding benchmark problems prepared by Working Group of Assessment of Shielding Experiments in the Research Committee on Shielding Design in the Atomic Energy Society of Japan were compiled by Shielding Laboratory in Japan Atomic Energy Research Institute. Fourteen shielding benchmark problems are presented newly in addition to twenty-one problems proposed already, for evaluating the calculational algorithm and accuracy of computer codes based on discrete ordinates method and Monte Carlo method and for evaluating the nuclear data used in codes. The present benchmark problems are principally for investigating the backscattering and the streaming of neutrons and gamma rays in two- and three-dimensional configurations. (author)

  12. Large screen mimic display design research for advanced main control room in nuclear power plant

    International Nuclear Information System (INIS)

    Zheng Mingguang; Yang Yanhua; Xu Jijun; Zhang Qinshun; Ning Zhonghe

    2002-01-01

    Firstly the evolution of mimic diagrams or displays used in the main control room of nuclear power plant was introduced. The active functions of mimic diagrams were analyzed on the release of operator psychological burden and pressure, the assistance of operator for the information searching, status understanding, manual actuation, correct decision making as well as the safe and reliable operation of the nuclear power plant. The importance and necessity to use the (large screen) mimic diagrams in advanced main control room of nuclear power plant, the design principle, design details and verification measures of large screen mimic display are also described

  13. Design and modernization of the control room with of the new digital I and C systems

    International Nuclear Information System (INIS)

    Fernandez, L. A.; Ortega, F.; Rejas, L.

    2011-01-01

    The use of the new digital I and c systems in the design of the new nuclear power plants, as well as the modernization of the existing ones, implies relevant changes in the control room design. New I and C systems provide new features that affect the control room operating concept, therefore a detailed analysis is required to take into consideration all the operating and human factor aspects. based on Tecnatom's experience, this article presents the methodological approach used as well as the most relevant aspects of this kind of project. (Author)

  14. The Control Room Upgrade in Oskarshamn 2 Modernization Project Lesson Learned from Ongoing Human Factor design

    International Nuclear Information System (INIS)

    Thomas, Gunnarsson; Magnus, Eliasson

    2011-01-01

    Due to recent changes in Swedish commercial nuclear safety system requirements, OKG decided to make the changes required by the new safety requirements, apply for a 30-year license extension, and to concurrently make changes for a major power uprate; this project is called the Plant Life Extension project (PLEX). It was decided, in addition to several plant modifications, to re build the old control room to a new modern screen-based control room located in the same space as the old one, and with the same number of operators. This paper explains the approach taken when modernizing the control room as a part of the Oskarshamn 2 Modernization project PLEX, the results, and the lessons learned from this ongoing work. The combination of changes results in a modernization project that is expected to increase output power by approximately 50 MWe through increased efficiency and to result in an increase in thermal power from 1800 MWt to 2300 MWt (28%) and electrical power from 620 MWe to 840 MWe due to the power uprate. The license to operate OKG2 expires in 2012 The PLEX project is one of the most ambitious nuclear power plant modernization projects ever implemented, world-wide. The application of human factors engineering (HFE) and control room and HSI design is a complex challenge. The original main control room from 1975 in Oskarshamn 2, was quite compact and provided a fairly good overview of the process. New requirements for enhanced safety and other design changes in the process systems and instrumentation led to a step-wise installation of new information and control equipment in the control room. Since the control room was quite limited in space, the control room grew larger, and the new equipment was installed farther away from the operator workplaces into an adjacent control room. This was even the case for the new safety systems. These systems were functioning well separately as such, but in some cases their interfaces were inconsistent, leading to increased

  15. Design and Characterization of a Gradient-Transparent RF Copper Shield for PET Detector Modules in Hybrid MR-PET Imaging

    Science.gov (United States)

    Berneking, Arne; Trinchero, Riccardo; Ha, YongHyun; Finster, Felix; Cerello, Piergiorgio; Lerche, Christoph; Shah, Nadim Jon

    2017-05-01

    This paper focuses on the design and the characterization of a frequency-selective shield for positron emission tomography (PET) detector modules of hybrid magnetic resonance-PET scanners, where the shielding of the PET cassettes is located close to the observed object. The proposed shielding configuration is designed and optimized to guarantee a high shielding effectiveness (SE) of up to 60 dB for B1-fields at the Larmor frequency of 64 MHz, thus preventing interactions between the radio-frequency (RF) coil and PET electronics. On the other hand, the shield is transparent to the gradient fields with the consequence that eddy-current artifacts in the acquired EPI images are significantly reduced with respect to the standard solid-shield configuration. The frequency-selective behavior of the shield is characterized and validated via simulation studies with CST MICROWAVE STUDIO in the megahertz and kilohertz range. Bench measurements with an RF coil built in-house demonstrated the high SE at the Larmor frequency. Moreover, measurements on a 4-T human scanner confirmed the abolishment of eddy current artifact and also provided an understanding of where the eddy currents occur with respect to the sequence parameters. Simulations and measurements for the proposed shielding concept were compared with a solid copper shielding configuration.

  16. An Overview of the Application of Human Factors Guidance to Control Room Design

    International Nuclear Information System (INIS)

    Yondola, Paul R.; Karlewicz, George T.

    2002-01-01

    A new power plant design has the goal of making major improvements in cost and ease of operation over previous designs. Improvements in the way information is organized and presented to control room operators based on established Human Factors Engineering (HFE) criteria is key to achieving these goals. An overview of the process and methods being employed in an ongoing design effort will be discussed, including the ways in which current Human Factors guidance is being applied in a unique operating environment

  17. Estimation of gamma dose rate from hulls and shield design for the hull transport cask of Fuel Reprocessing Plant (FRP)

    International Nuclear Information System (INIS)

    Chandrasekaran, S.; Rajagopal, V.; Jose, M.T.; Venkatraman, B.

    2012-01-01

    In Fuel Reprocessing Plant (FRP), un-dissolved clad of fuel pins known as hulls are the major sources of high level solid waste. Safe handling, transport and disposal require the estimation of radioactivity as a consequent of gamma dose rate from hulls in fast reactor fuel reprocessing plant in comparison with thermal reactor fuel. Due to long irradiation time and low cooling of spent fuel, the evolution of activation products 51 Cr, 58 Co, 54 Mn and 59 Fe present as impurities in the fuel clad are the major sources of gamma radiation. Gamma dose rate from hull container with hulls from Fuel Sub Assembly (FSA) and Radial Sub Assembly (RSA) of Fuel Reprocessing Plant (FRP) was estimated in order to design the hull transport cask. Shielding computations were done using point kernel code, IGSHIELD. This paper describes the details of source terms, estimation of dose rate and shielding design of hull transport cask in detail. (author)

  18. Nuclear analysis and shielding optimisation in support of the ITER In-Vessel Viewing System design

    International Nuclear Information System (INIS)

    Turner, Andrew; Pampin, Raul; Loughlin, M.J.; Ghani, Zamir; Hurst, Gemma; Lo Bue, Alessandro; Mangham, Samuel; Puiu, Adrian; Zheng, Shanliang

    2014-01-01

    The In-Vessel Viewing System (IVVS) units proposed for ITER are deployed to perform in-vessel examination. During plasma operations, the IVVS is located beyond the vacuum vessel, with shielding blocks envisaged to protect components from neutron damage and reduce shutdown dose rate (SDR) levels. Analyses were conducted to determine the effectiveness of several shielding configurations. The neutron response of the system was assessed using global variance reduction techniques and a surface source, and shutdown dose rate calculations were undertaken using MCR2S. Unshielded, the absorbed dose to piezoelectric motors (PZT) was found to be below stable limits, however activation of the primary closure plate (PCP) was prohibitively high. A scenario with shielding blocks at probe level showed significantly reduced PCP contact dose rate, however still marginally exceeded port cell requirements. The addition of shielding blocks at the bioshield plug demonstrated PCP contact dose rates below project requirements. SDR levels in contact with the isolated IVVS cartridge were found to marginally exceed the hands-on maintenance limit. For engineering feasibility, shielding blocks at bioshield level are to be avoided, however the port cell SDR field requires further consideration. In addition, alternative low-activation steels are being considered for the IVVS cartridge

  19. Nuclear analysis and shielding optimisation in support of the ITER In-Vessel Viewing System design

    Energy Technology Data Exchange (ETDEWEB)

    Turner, Andrew, E-mail: andrew.turner@ccfe.ac.uk [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Pampin, Raul [F4E Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Loughlin, M.J. [ITER Organisation, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Ghani, Zamir; Hurst, Gemma [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Lo Bue, Alessandro [F4E Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Mangham, Samuel [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Puiu, Adrian [F4E Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Zheng, Shanliang [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom)

    2014-10-15

    The In-Vessel Viewing System (IVVS) units proposed for ITER are deployed to perform in-vessel examination. During plasma operations, the IVVS is located beyond the vacuum vessel, with shielding blocks envisaged to protect components from neutron damage and reduce shutdown dose rate (SDR) levels. Analyses were conducted to determine the effectiveness of several shielding configurations. The neutron response of the system was assessed using global variance reduction techniques and a surface source, and shutdown dose rate calculations were undertaken using MCR2S. Unshielded, the absorbed dose to piezoelectric motors (PZT) was found to be below stable limits, however activation of the primary closure plate (PCP) was prohibitively high. A scenario with shielding blocks at probe level showed significantly reduced PCP contact dose rate, however still marginally exceeded port cell requirements. The addition of shielding blocks at the bioshield plug demonstrated PCP contact dose rates below project requirements. SDR levels in contact with the isolated IVVS cartridge were found to marginally exceed the hands-on maintenance limit. For engineering feasibility, shielding blocks at bioshield level are to be avoided, however the port cell SDR field requires further consideration. In addition, alternative low-activation steels are being considered for the IVVS cartridge.

  20. The Effects of Interior Design on Communication and Impressions of a Counselor in a Counseling Room

    Science.gov (United States)

    Miwa, Yoshiko; Hanyu, Kazunori

    2006-01-01

    This study aimed to investigate effects of the interior design of a counseling room on participants' self-disclosure and impressions of a counselor. The authors examined the effects of lighting and decorations. It tested four conditions crossing decorations (with or without home-like decorations) and type of lighting (bright or dim). Eighty…

  1. The design and operation of the THORP central control room: a human factors perspective

    International Nuclear Information System (INIS)

    Reed, Julie.

    1996-01-01

    The new Thermal Oxide Reprocessing Plant (THORP) at British Nuclear Fuels (BNFL) Sellafield Site is now operational. This paper describes the Central Control Room (CCR), focusing on the control system components. Throughout the design, commissioning and operation of THORP, human factors played an important part. (author)

  2. Design of air distribution system in operating rooms -theory versus practice

    NARCIS (Netherlands)

    Melhado, M.A.; Loomans, M.G.L.C.; Hensen, J.L.M.; Lamberts, R.

    2016-01-01

    Air distribution systems need to secure a good indoor air quality in operating rooms (ORs), minimize the risk of surgical site infections, and establish suitable working conditions for the surgical team through the thermal comfort. The paper presents an overview of the design and decision process of

  3. Nucleonic analysis of a preliminary design for the ETF neutral-beam-injector duct shielding

    International Nuclear Information System (INIS)

    Urban, W.T.; Seed, T.J.; Dudziak, D.J.

    1980-01-01

    A nucleonic analysis of the Engineering Test Facility Neutral-Beam-Injector duct shielding has been made using a hybrid Monte Carlo/discrete-ordinates method. This method used Monte Carlo to determine internal and external boundary surface sources for a subsequent discrete-ordinates calculation of the neutron and gamma-ray transport through the shield. The analysis also included determination of the energy and angular distribution of neutrons and gamma rays entering the duct from the torus plasma chamber. Confidence in the hybrid method and the results obtained were provided through a comparison with three-dimensional Monte Carlo results

  4. Virtual reality verification of workplace design guidelines for the process plant control room

    International Nuclear Information System (INIS)

    Droeivoldsmo, Asgeir; Nystad, Espen; Helgar, Stein

    2001-02-01

    Early identification of potential human factors guideline-violations and corrective input into the design process is desired for efficient and cost-effective control room design. Virtual reality (VR) technology makes it possible to perform evaluation of the design of the control room at an early stage of the design process, but can we trust the results from such evaluations? This paper describes an experimental validation of a VR model against the real world in five different guideline verification tasks. Results indicate that guideline verification in the VR model can be done with satisfactory accuracy for a number of evaluations. However, some guideline categories require further development of measurement tools and use of a model with higher resolution than the model used in this study. (Author). 30 refs., 4 figs., 1 tab

  5. SHIELD 1.0: development of a shielding calculator program in diagnostic radiology

    International Nuclear Information System (INIS)

    Santos, Romulo R.; Real, Jessica V.; Luz, Renata M. da; Friedrich, Barbara Q.; Silva, Ana Maria Marques da

    2013-01-01

    In shielding calculation of radiological facilities, several parameters are required, such as occupancy, use factor, number of patients, source-barrier distance, area type (controlled and uncontrolled), radiation (primary or secondary) and material used in the barrier. The shielding design optimization requires a review of several options about the physical facility design and, mainly, the achievement of the best cost-benefit relationship for the shielding material. To facilitate the development of this kind of design, a program to calculate the shielding in diagnostic radiology was implemented, based on data and limits established by National Council on Radiation Protection and Measurements (NCRP) 147 and SVS-MS 453/98. The program was developed in C⌗ language, and presents a graphical interface for user data input and reporting capabilities. The module initially implemented, called SHIELD 1.0, refers to calculating barriers for conventional X-ray rooms. The program validation was performed by the comparison with the results of examples of shielding calculations presented in NCRP 147.

  6. Design of a PET/CT facility considering the shielding calculation in accordance with AAPM TG-108; Diseno de una instalacion PET/CT considerando el calculo de blindaje segun AAPM TG-108

    Energy Technology Data Exchange (ETDEWEB)

    Guevara R, V. Y.; Romero C, N. [Empresa QC DOSE S. A. C., Av. Tomas Marsano 1915, Surquillo, Lima 34 (Peru); Berrocal T, M., E-mail: vguevara@qcdose.com [Universidad Nacional Mayor de San Marcos, C. German Amezaga 375, Edif. Jorge Basadre, Ciudad Universitaria, Lima 1 (Peru)

    2014-08-15

    A Positron Emission Tomography / Computed Tomography facility may require protection barriers on floor, ceiling and walls, because the patient becomes a radioactive source that emits photons of 0.511 MeV, after having received a radiopharmaceutical, usually F-18 fluorodeoxyglucose (F-18 FDG). This work has as objective to propose the design of a PET/CT facility, taking into account technical and radiation protection considerations applied internationally, and also develop the necessary shielding for such installation by applying as published by the American Association of Physicists in Medicine Task Group Report 108. A shielding spreadsheet in Excel program was developed with reference to the recommendations of the AAPM TG - 08, to determine the shielding required for the walls, floor and ceiling. For fixing the radiation levels in the shielding calculation has been considered the actual restrictions for the occupationally exposed personnel (100 μSv/week) as well as the people in general (20 μSv/ week). The radiopharmaceutical used as a reference for the shielding calculation was the F-18 FDG. With the assistance of an architectural plan were determined distances from potential sources of radiation in facility (uptake and image acquisition living rooms) to points of interest around them. Finally the thickness of the protective barriers in lead and concrete necessary to achieve the established radiation levels were calculated and these results were stored in a table. This paper shows that technical aspects considered in the design of the installation and environments distribution can improve work processes within the PET/CT facility, consequently resulting in a reduction of the dose levels for people in general. (author)

  7. ICU architectural design affects the delirium prevalence: a comparison between single-bed and multibed rooms*.

    Science.gov (United States)

    Caruso, Pedro; Guardian, Lilian; Tiengo, Tatiane; Dos Santos, Lucio Souza; Junior, Pedro Medeiros

    2014-10-01

    Delirium risk factors are related to the patients' acute and chronic clinical condition, treatment, and environment. The environmental risk factors are essentially determined by the ICU architectural design. Although there are countless architectural variations among the ICUs, all can be classified as single- or multibed rooms. Our objectives were to compare the ICU delirium prevalence and characteristics (coma/delirium-free days, first day in delirium, and delirium motoric subtypes) of critically ill patients admitted in single- or multibed rooms. Retrospective. ICU of a teaching oncologic hospital with 31 beds. Twenty-three beds distributed in one multibed room with 13 beds and other with 10 beds. Eight beds distributed in single-bed rooms. All adult patients admitted from February to November 2011. None. We evaluated 1,587 patients and included 1,253 patients. Patients' characteristics at ICU admission and their outcomes along the ICU stay were not different between patients admitted in single- or multibed rooms. One hundred sixty-three patients (13.0%) had delirium, and the prevalence was significantly lower in patients admitted in single-bed rooms (6.8% × 15.1%; p < 0.01). This lower prevalence occurred in patients admitted due to a medical (11.0% × 25.6%; p < 0.01) or postoperative (5.0% × 11.4%; p < 0.01) reason. However, the coma/delirium-free days, the first day in delirium, and the delirium motoric subtypes were not different between the single- and multibed rooms. The risk factors associated with delirium were admission in multibed rooms (odds ratio, 4.03; 95% CI, 2.13-7.62), older age, ICU-acquired infection, and higher Simplified Acute Physiology Score 3 and Sequential Organ Failure Assessment score. Critically ill patients admitted in single-bed rooms have a lower prevalence of delirium than those admitted in multibed rooms. However, coma/delirium-free days, first day in delirium, and motoric subtypes were not different.

  8. Comparison of In-Vessel Shielding Design Concepts between Sodium-cooled Fast Burner Reactor and the Sodium-cooled Fast Breeder Reactor

    International Nuclear Information System (INIS)

    Yun, Sunghwan; Kim, Sang Ji

    2015-01-01

    In this study, quantities of in-vessel shields were derived and compared each other based on the replaceable shield assembly concept for both of the breeder and burner SFRs. Korean Prototype Gen-IV Sodium-cooled Fast Reactor (PGSFR) like SFR was used as the reference reactor and calculation method reported in the reference was used for shielding analysis. In this paper, characteristics of in-vessel shielding design were studied for the burner SFR and breeder SFR based on the replaceable shield assembly concept. An in-vessel shield to prevent secondary sodium activation (SSA) in the intermediate heat exchangers (IHXs) is one of the most important structures for the pool type Sodium-cooled Fast Reactor (SFR). In our previous work, two in-vessel shielding design concepts were compared each other for the burner SFR. However, a number of SFRs have been designed and operated with the breeder concept, in which axial and radial blankets were loaded for fuel breeding, during the past several decades. Since axial and radial blanket plays a role of neutron shield, comparison of required in-vessel shield amount between the breeder and burner SFRs may be an interesting work for SFR designer. Due to the blanket, the breeder SFR showed better performance in axial neutron shielding. Hence, 10.1 m diameter reactor vessel satisfied the design limit of SSA at the IHXs. In case of the burner SFR, due to more significant axial fast neutron leakage, 10.6 m diameter reactor vessel was required to satisfy the design limit of SSA at the IHXs. Although more efficient axial shied such as a mixture of ZrH 2 and B 4 C can improve shielding performance of the burner SFR, additional fabrication difficulty may mitigate the advantage of improved shielding performance. Therefore, it can be concluded that the breeder SFR has better characteristic in invessel shielding design to prevent SSA at the IHXs than the burner SFR in the pool-type reactor

  9. [Design and Implementation of a Mobile Operating Room Information Management System Based on Electronic Medical Record].

    Science.gov (United States)

    Liu, Baozhen; Liu, Zhiguo; Wang, Xianwen

    2015-06-01

    A mobile operating room information management system with electronic medical record (EMR) is designed to improve work efficiency and to enhance the patient information sharing. In the operating room, this system acquires the information from various medical devices through the Client/Server (C/S) pattern, and automatically generates XML-based EMR. Outside the operating room, this system provides information access service by using the Browser/Server (B/S) pattern. Software test shows that this system can correctly collect medical information from equipment and clearly display the real-time waveform. By achieving surgery records with higher quality and sharing the information among mobile medical units, this system can effectively reduce doctors' workload and promote the information construction of the field hospital.

  10. Technical and Economic Aspects of Designing an Efficient Room Air-Conditioner Program in India

    Energy Technology Data Exchange (ETDEWEB)

    Abhyankar, Nikit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Div.; Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Div.; Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Div.; Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Div.

    2017-09-05

    Several studies have projected a massive increase in the demand for air conditioners (ACs) over the next two decades in India. By 2030, room ACs could add 140 GW to the peak load, equivalent to over 30% of the total projected peak load. Therefore, there is significant interest among policymakers, regulators, and utilities in managing room AC demand by enhancing energy efficiency. Building on the historical success of the Indian Bureau of Energy Efficiency’s star-labeling program, Energy Efficiency Services Limited recently announced a program to accelerate the sale of efficient room ACs using bulk procurement, similar to their successful UJALA light-emitting diode (LED) bulk procurement program. This report discusses some of the key considerations in designing a bulk procurement or financial incentive program for enhancing room AC efficiency in India. We draw upon our previous research to demonstrate the overall technical potential and price impact of room AC efficiency improvement and its technical feasibility in India. We also discuss the importance of using low global warming potential (GWP) refrigerants and smart AC equipment that is demand response (DR) ready.

  11. Design of a Clean Room for Quality Control of an Environmental Sampling in KINAC

    International Nuclear Information System (INIS)

    Yoon, Jongho; Ahn, Gil Hoon; Seo, Hana; Han, Kitek; Park, Il Jin

    2014-01-01

    The objective of environmental sampling and analysis for safeguards is to characterize the nuclear materials handled and the activities conducted at the specific locations. The KINAC is responsible for the conclusions drawn from the analytical results provided by the analytical laboratories. To assure the KINAC of the continuity of the quality of the analytical results provided by the laboratories, the KINAC will implement a quality control(QC) programme. One of the QC programme is to prepare QC samples. The establishment of a clean room is needed to handle QC samples due to stringent control of contamination. The KINAC designed a clean facility with cleanliness of ISO Class 6, the Clean Room for Estimation and Assay of trace Nuclear materials(CREAN) to meet conflicting requirements of a clean room and for handling of nuclear materials according to Korean laws. The clean room will be expected to acquire of a radiation safety license under these conditions in this year and continue to improve it. The construction of the CREAN facility will be completed by the middle of 2015. In terms of QC programme, the establishment of a clean room is essential and will be not only very helpful for setting of quality control system for the national environmental sampling programme but also be applied for the environmental sample analysis techniques to the nuclear forensics

  12. Characterization of Magnetic Field Immersed Photomultipliers from Double Chooz Experiment. Design and Construction of their Magnetic Shields

    International Nuclear Information System (INIS)

    Valdivia Valero, F. J.

    2007-01-01

    Flavour oscillations of neutrinos are a quantum-mechanical effect widely demonstrated. It is explained through interferences of their mass eigenstates, therefore, belonging to the physical area beyond the Standard Model. This work deals with the CIEMAT collaboration in the neutrino experiment Double Chooz. Such an experiment aims to measure the mixture angle θ 1 3, one of the PMNS leptonic mixture matrix, with a un reached-before sensibility by decrease of systematic errors. For this, two identical scintillator detectors, equipped with PMT's, will be sited at different distances from two reactors located in the nuclear power plant CHOOZ B (France). The electronic neutrino flux from these reactors will be compared, explaining its deficit by flavour oscillations of these particles. The identity of both detectors will be diminished by the magnetic field effects on the PMT's response. Therefore, this study serves as for quantifying such an effects as for fitting the magnetic shields design that minimize them. Shielding measurements and final design of magnetic shields as much as the effect these ones cause in the PMT's response immersed in a monitored magnetic field are presented. (Author) 85 refs

  13. Analysis of the operator's tasks: An aid to control room design

    International Nuclear Information System (INIS)

    Blanc, P.; Guesnier, G.P.; Heilbronn, B.; Monnier, B.

    1983-01-01

    The control room designer usually has no knowledge of the tasks performed by the operator in the control room since an overall picture of the situation only becomes available once the whole facility has been constructed. In order to study and design control rooms for its future PWR units, Electricite de France (EDF) felt it was essential to analyse these tasks: the work was facilitated by the existence of 900 MW PWR units which were already in operation and which are controlled in much the same manner as future units of the same type. Accordingly, by analysing the control procedures of these 900 MW PWR units, a data base describing the control and monitoring tasks performed by operators in normal, incident and accident situations has been built up. The data-base files, which were established from a study of 130 control procedures, record all the commands given and data available in the control room (about 7000), describe the tasks connected with these commands and data, and identify the times at which they are made use of by the operator. Using this data base, the principle of operator-system communication and of data processing in the control room of the future has been established: in such a control room, most controls and data will be accessible through computer communication systems to ensure that control and monitoring systems are closely integrated under normal operating conditions as well as in incident and post-accident situations and to enable the plant to be controlled by one or two operators in a seated position. (author)

  14. A study on radiation shield design of storage facility for low and intermediate level radioactive waste in Bangladesh

    International Nuclear Information System (INIS)

    Khan, JJahirul Haque

    2005-02-01

    Bangladesh has no nuclear power reactor but has only one 3 MW TRIGA Mark-II Research Reactor. The Bangladesh Atomic Energy commission (BAEC) operates a 3 MW TRIGA Mark-II Research Reactor and maintains not only the nuclear facilities at its Atomic Energy Research Establishment (AERE) at Savar (near Dhaka) but also the related radiation facilities the whole country. The main sources of radioactive wastes result from the use of sealed and unsealed radiation sources in medicine industry, research, agriculture, etc as well as from operation and maintenance of the nuclear facilities the whole country. As a result radioactive wastes are increasing day by day and these wastes are classified as low and intermediate level radioactive waste (LILW) following the radiation safety philosophy of IAEA recommendations in Bangladesh. Radioactive waste is very sensitive issue to public and environment from the hazardous standpoint of ionizing radiation. Therefore, storage facility of LILW is very essential for safe radioactive waste management in Bangladesh and in parallel: this study is of a great importance due to new installation of this storage facility in future. The basic objective of this study is to recommend the radiation shield design parameters of the installation of storage facility for low and intermediate level radioactive waste from the points of view of radiation safety and sensitivity analysis. The shield design of this installation has been carried out with the Monte Carlo Code MCNP4C and the point Kernel Code Micro Shield 5.05 respectively considering the ICRP-60 (1990) recommendations for occupational exposure limit (10 μ Sv/hr). For more safety purpose every equivalent dose rate at different positions of this installation is considered below 9 μ Sv/hr in this study. The radiation shield design parameters are recommended based on MCNP4C calculated results than those of Micro Shield due to more credible results and these parameters are: (I) 51 cm thickness of

  15. Design of a permanent Cd-shielded epithermal neutron irradiation site in the Syrian Miniature Neutron Source Reactor

    International Nuclear Information System (INIS)

    Khattab, K.; Haddad, Kh.; Haj-Hassan, H.

    2008-01-01

    A Cd-shield (cylindrical shell 1 mm in thickness, 34 mm in diameter and 180 mm in length) was used to design a permanent epithermal neutron irradiation site for epithermal neutron activation analysis (ENAA) in the Syrian Miniature Neutron Source Reactor (MNSR). This site was achieved by shielding the surface of the aluminum tube of one of the outer irradiation sites. The calculated depression ratio of thermal neutron flux was 1/10. Homogeneity of the neutron flux in the first outer irradiation site has been found numerically using the WIMSD4 and CITATION codes and experimentally by irradiating five short copper wires using the outer irradiation capsule. Good agreement was obtained between the calculated and the measured results of the neutron flux distributions. (author)

  16. Design of a permanent Cd-shielded epithermal neutron irradiation site in the Syrian Miniature Neutron Source Reactor

    International Nuclear Information System (INIS)

    Khattab, K.; Haddad, Kh.; Haj-Hassan, H.

    2009-01-01

    A Cd-shield (cylindrical shell 1 mm in thickness, 34 mm in diameter and 180 mm in length) was used to design a permanent epithermal neutron irradiation site for epithermal neutron activation analysis (ENAA) in the Syrian Miniature Neutron Source Reactor (MNSR). This site was achieved by shielding the surface of the aluminum tube of one of the outer irradiation sites. The calculated depression ratio of thermal neutron flux was 1/10. Homogeneity of the neutron flux in the first outer irradiation site has been found numerically using the WIMSD4 and CITATION codes and experimentally by irradiating five short copper wires using the outer irradiation capsule. Good agreement was obtained between the calculated and the measured results of the neutron flux distributions. (author)

  17. Ammunition Peculiar Equipment (APE) 1995, NIR Propellant Analyzer, to MIL-STD-398, Military Standard Shields, Operational for Ammunition Operations, Criteria for Design of and Tests for Acceptance

    National Research Council Canada - National Science Library

    2003-01-01

    ... (SJMAC-DEM) to test the Ammunition Peculiar Equipment (APE) 1995 NIR Propellant Analyzer, to MIL-STD-398, "Military Standard Shields, Operational for Ammunition Operations, Criteria for Design of and Tests for Acceptance...

  18. Design lead shielded casks for shipment and spent fuel from power reactors to reprocessing plant at Tarapur

    International Nuclear Information System (INIS)

    Seetharamaiah, P.

    1975-01-01

    Spent fuels from the Tarapur and Rajasthan Atomic Power Stations (TAPS and RAPS) are shipped to Fuel Reprocessing Plant at Tarapur in heavily lead shielded casks weighing about 65 tonnes as they are highly radioactive. The design of the casks has to meet stringemt requirements of safety and the integrity should be ensured to contain activity under credible accidents during handling and transportation. The paper presents the design of two casks for TAPS and RAPS spent fuel transportation particularly with reference to stress analysis considerations. The analysis also includes the handling gadgets and tie down attachments on the rail wagon and road trailer. (author)

  19. Design of nuclear power plant control rooms: some findings and possible improvements

    International Nuclear Information System (INIS)

    Bohr, E.

    1984-01-01

    Major findings are described of a study on the present status and possible improvements in the design of nuclear power plant control rooms according to ergonomic principles and criteria. The findings have been acquired by observing the performance of control room operators, by interviewing operators and management personnel, and by analysing major characteristics of the man-machine interface. The methods currently used for developing and designing control rooms have also been examined. The results of the study indicate that there is a growing awareness and consideration of physical factors affecting performance. More attention should be paid to the essential cognitive characteristics of work in the control room with the aim of avoiding unnecessary hindrances and possible errors. Examples are given of some of these problems, and approaches, ways and means for solving or mitigating them are indicated. A more deliberate consideration of factors affecting operator performance and reliability is suggested, based on a systems ergonomics approach. Analyses of critical tasks would be a major feature of this approach. Its main objective is to ensure that operators are able to carry out their tasks reliably. (author)

  20. Shielding practice

    International Nuclear Information System (INIS)

    Sauermann, P.F.

    1985-08-01

    The basis of shielding practice against external irradiation is shown in a simple way. For most sources of radiation (point sources) occurring in shielding practice, the basic data are given, mainly in the form of tables, which are required to solve the shielding problems. The application of these data is explained and discussed using practical examples. Thickness of shielding panes of glove boxes for α and β radiation; shielding of sealed γ-radiography sources; shielding of a Co-60 radiation source, and of the manipulator panels for hot cells; damping factors for γ radiation and neutrons; shielding of fast and thermal neutrons, and of bremsstrahlung (X-ray tubes, Kr-85 pressure gas cylinders, 42 MeV betatrons, 20 MeV linacs); two-fold shielding (lead glass windows for hot cells, 14 MeV neutron generators); shielding against scattered radiation. (orig./HP) [de

  1. Perfecting of shielding calculation technique against the gamma rays arising from a Tokamak with the TFR experience. Application to the conceptual design Tokamak TORE 2 SUPRA

    International Nuclear Information System (INIS)

    Diop, Cheikh M'Backe.

    1980-09-01

    The conception of the necessary shielding around a conceptual design Tokamak requires to execute an estimated calculation of the doses due to the different radiation sources arising from the machine: the thermonuclear neutron source and the gamma ray source emitted during the interaction of the runaway electrons with the diaphragm. In this study, we propose a theorical method to calculate this gamma source. We tackle also the shielding problem of the conceptual design Tokamak: TORE 2 SUPRA [fr

  2. Design of an integral missile shield in integrated head assembly for pressurized water reactor at commercial nuclear plants

    International Nuclear Information System (INIS)

    Baliga, Ravi; Watts, Tom Neal; Kamath, Harish

    2015-01-01

    In ICONE22, the authors presented the Integrated Head Assembly (IHA) design concept implemented at Callaway Nuclear Power Plant in Missouri, USA. The IHA concept is implemented to reduce the outage duration and the associated radiation exposure to the workers by reducing critical path time during Plant Refueling Outage. One of the head area components in the IHA is a steel missile shield designed to protect the Control Rod Drive Mechanism (CRDM) assembly from damaging other safety-related components in the vicinity in the Containment. Per Federally implemented General Design Criteria for commercial nuclear plants in the USA, the design of Nuclear Steam Supply System (NSSS) must provide protection from the damages caused by a postulated event of CRDM housing units and their associated parts disengaging from the reactor vessel assembly. This event is considered as a Loss of Coolant Accident (LOCA) and assumes that once the CRDM housing unit and their associated parts disengage from the reactor vessel internals assembly, they travel upward by the water jet with the following sequence of events: Per Reference 1, the drive shaft and control rod cluster are forced out of the reactor core by the differential pressure across the drive shaft with the assumption that the drive shaft and control rod cluster, latched together, are fully inserted when the accident occurs. After the travel, the rod cluster control spider will impact the lower side of the upper support plate inside the reactor vessel fracturing the flexure arms in the joint freeing the drive shaft from the control rod cluster. The control rod cluster is stopped by the upper support plate and will remain below the upper support plate during this accident. However, the drive shaft will continue to accelerate in the upward direction until it is stopped by a safety feature in the IHA. The integral missile shield as a safety feature in the IHA is designed to stop the CRDM drive shaft from moving further up in the

  3. Equalization of Loudspeaker and Room Responses Using Kautz Filters: Direct Least Squares Design

    Directory of Open Access Journals (Sweden)

    Karjalainen Matti

    2007-01-01

    Full Text Available DSP-based correction of loudspeaker and room responses is becoming an important part of improving sound reproduction. Such response equalization (EQ is based on using a digital filter in cascade with the reproduction channel to counteract the response errors introduced by loudspeakers and room acoustics. Several FIR and IIR filter design techniques have been proposed for equalization purposes. In this paper we investigate Kautz filters, an interesting class of IIR filters, from the point of view of direct least squares EQ design. Kautz filters can be seen as generalizations of FIR filters and their frequency-warped counterparts. They provide a flexible means to obtain desired frequency resolution behavior, which allows low filter orders even for complex corrections. Kautz filters have also the desirable property to avoid inverting dips in transfer function to sharp and long-ringing resonances in the equalizer. Furthermore, the direct least squares design is applicable to nonminimum-phase EQ design and allows using a desired target response. The proposed method is demonstrated by case examples with measured and synthetic loudspeaker and room responses.

  4. Shield evaluation and validation for design and operation of facility for treatment of legacy Intermediate Level Radioactive Liquid Waste (ILW)

    International Nuclear Information System (INIS)

    Deepa, A.; Jakhete, A.P.; Rathish, K.R.; Saroj, S.K.; Patel, H.S.; Gopalakrishnan, R.K.; Gangadharan, Anand; Singh, Neelima

    2014-01-01

    An ion exchange treatment facility has been commissioned at PRIX facility, for the treatment of legacy ILW generated at reprocessing plant, Trombay. The treatment system is based on the deployment of selective sorbents for removal of cesium and strontium from ILW. Activity concentration due to beta emitters likely to be processed is of the order of 111-1850 MBq/l. Dose rates in different areas of the facility were evaluated using shielding code and design input. Present work give details of the comparison of dose rates estimated and dose rates measured at various stages of the processing of ILW. At PRIX, the ILW treatment system comprises of shielded IX columns (two cesium and one strontium) housed in a MS cubicle the process lines inlet and outlet of IX treatment system and effluent storage tanks. The MS cubicle, prefilter and piping are housed in a process cell of 500 mm concrete shielding. Effluent storage tanks are outside processing building. Theoretical assessment of expected dose rates were carried out prior to installation of various systems in different areas of PRIX. Dose rate on IX column and MS cubicle for a maximum inventory of 3.7x10 7 MBq of 137 Cs and its contribution in operating gallery was estimated

  5. Concept of Advanced Back-up Control Panel Design of Digital Main Control Room

    International Nuclear Information System (INIS)

    Jiang, Guo Jin; Sun, Yong Bin; Tan, Ke; Zhang, Li Ming; Shi, Ji; Zhang, Xue Gang; Huang, Wei Jun; Mao, Ting; Liu Yanzi

    2011-01-01

    Back-up control panel (BCP) of digital main control room (DMCR) is the backup means for main computerized control means (MCM). This paper focus on technical issues for advanced design of Backup Panel (BCP) for CPR1000 using qualified computer-based video display unit to display plant process indication and alarms. HFE issues also have been considered in the BCP design. Then, mean to fulfill safety target of NPP, best ergonomic effect has been described. At last conclusion on advanced BCP design is provided

  6. Concept of Advanced Back-up Control Panel Design of Digital Main Control Room

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Guo Jin; Sun, Yong Bin; Tan, Ke; Zhang, Li Ming; Shi, Ji; Zhang, Xue Gang; Huang, Wei Jun; Mao, Ting; Liu Yanzi [China Nuclear Power Engineering Company, Shenzen (China)

    2011-08-15

    Back-up control panel (BCP) of digital main control room (DMCR) is the backup means for main computerized control means (MCM). This paper focus on technical issues for advanced design of Backup Panel (BCP) for CPR1000 using qualified computer-based video display unit to display plant process indication and alarms. HFE issues also have been considered in the BCP design. Then, mean to fulfill safety target of NPP, best ergonomic effect has been described. At last conclusion on advanced BCP design is provided.

  7. THE APPLICATION OF EVIDENCE BASED DESIGN IN EMERGENCY ROOM OF PUBLIC HOSPITAL OF DR. R. SOSODORO DJATIKOESOEMO BOJONEGORO

    Directory of Open Access Journals (Sweden)

    Noerkayatin ,

    2015-07-01

    Full Text Available The Hospital facilities built under Evidence Based Design (EBD will create a safe and comfortable environment, lower the nosocomial infection, quicken the patient recovery, lower the treatment cost, and improve staffs’ performance. The emergency room of public hospital of Dr.R.Sosodoro Djatikoesoemo Bojonegoro needs to be redesigned because the existing design does not meet physical safety. The reparation should refer to Facilities and Safety Management (FMS, Indonesian regulation, EBD concept and benchmarking to RSCM Jakarta considered as an application sample. This research applies case study with descriptive single case study design. The result of the research shows that reparation should be done that includes site and location, building components, and rooms lay out. The width of the rooms should meet minimal standard. The placing of triage room and resuscitation should be in the front area. Sinks should be located near the entrance of every room. The isolation and decontamination rooms should be provided.

  8. REPOSITORY LAYOUT SUPPORTING DESIGN FEATURE NO.13 - WASTE PACKAGE SELF SHIELDING

    International Nuclear Information System (INIS)

    Owen, J.

    1999-01-01

    The objective of this analysis is to develop a repository layout, for Feature No. 13, that will accommodate self-shielding waste packages (WP) with an areal mass loading of 25 metric tons of uranium per acre (MTU/acre). The scope of this analysis includes determination of the number of emplacement drifts, amount of emplacement drift excavation required, and a preliminary layout for illustrative purposes

  9. Structural Shielding Design of a 6 MV Flattening Filter Free Linear Accelerator: Indian Scenario

    OpenAIRE

    Mishra, Bibekananda; Selvam, T. Palani; Sharma, P. K. Dash

    2017-01-01

    Detailed structural shielding of primary and secondary barriers for a 6 MV medical linear accelerator (LINAC) operated with flattening filter (FF) and flattening filter free (FFF) modes are calculated. The calculations have been carried out by two methods, one using the approach given in National Council on Radiation Protection (NCRP) Report No. 151 and the other based on the monitor units (MUs) delivered in clinical practice. Radiation survey of the installations was also carried out. NCRP a...

  10. [Design of an anesthesia and micro-environment information management system in mobile operating room].

    Science.gov (United States)

    Wang, Xianwen; Liu, Zhiguo; Zhang, Wenchang; Wu, Qingfu; Tan, Shulin

    2013-08-01

    We have designed a mobile operating room information management system. The system is composed of a client and a server. A client, consisting of a PC, medical equipments, PLC and sensors, provides the acquisition and processing of anesthesia and micro-environment data. A server is a powerful computer that stores the data of the system. The client gathers the medical device data by using the C/S mode, and analyzes the obtained HL7 messages through the class library call. The client collects the micro-environment information with PLC, and finishes the data reading with the OPC technology. Experiment results showed that the designed system could manage the patient anesthesia and micro-environment information well, and improve the efficiency of the doctors' works and the digital level of the mobile operating room.

  11. Evaluation of human factors in interface design in main control rooms

    International Nuclear Information System (INIS)

    Hwang, S.-L.; Liang, S.-F.M.; Liu, T.-Y.Y.; Yang, Y.-J.; Chen, P.-Y.; Chuang, C.-F.

    2009-01-01

    An evaluation of human factors in a new nuclear power plant was conducted prior to the beginning of any business operations. After the task analysis and observation of training, two stages of interviews were carried out with the operators in the Fourth Nuclear Power Plant (NPP4). The main concerns identified were problems resulting from the operating interface of the display and controls in the main control room, usability of procedures, and the layout of the main control room. The latent human errors and suggestions were listed, and the top three problems were analyzed. The operators indicated that the alarm design issues and the critical problem of the operating mode with the VDU were worth further study in order to provide suggestions for a new interface design for future power plants.

  12. Computer modeling and design of diagnostic workstations and radiology reading rooms

    Science.gov (United States)

    Ratib, Osman M.; Amato, Carlos L.; Balbona, Joseph A.; Boots, Kevin; Valentino, Daniel J.

    2000-05-01

    We used 3D modeling techniques to design and evaluate the ergonomics of diagnostic workstation and radiology reading room in the planning phase of building a new hospital at UCLA. Given serious space limitations, the challenge was to provide more optimal working environment for radiologists in a crowded and busy environment. A particular attention was given to flexibility, lighting condition and noise reduction in rooms shared by multiple users performing diagnostic tasks as well as regular clinical conferences. Re-engineering workspace ergonomics rely on the integration of new technologies, custom designed cabinets, indirect lighting, sound-absorbent partitioning and geometric arrangement of workstations to allow better privacy while optimizing space occupation. Innovations included adjustable flat monitors, integration of videoconferencing and voice recognition, control monitor and retractable keyboard for optimal space utilization. An overhead compartment protecting the monitors from ambient light is also used as accessory lightbox and rear-view projection screen for conferences.

  13. Important changes in medical x-ray imaging facility shielding design methodology. A brief summary of recommendations in NCRP Report No. 147

    International Nuclear Information System (INIS)

    Archer, Benjamin R.; Gray, Joel E.

    2005-01-01

    The recently published Report No. 147 of The National Council on Radiation Protection and Measurements entitled 'Structural shielding design for medical x-ray imaging facilities' provides an update of shielding recommendations for x rays used for medical imaging. The goal of this report is to ensure that the shielding in these facilities limits radiation exposures to employees and members of the public to acceptable levels. Board certified medical and health physicists, as defined in this report, are the 'qualified experts' who are competent to design radiation shielding for these facilities. As such, physicists must be aware of the new technical information and the changes from previous reports that Report No. 147 supersedes. In this article we summarize the new data, models and recommendations for the design of radiation barriers in medical imaging facilities that are presented in Report No. 147

  14. Child abuse inventory at emergency rooms: CHAIN-ER rationale and design

    Directory of Open Access Journals (Sweden)

    Nieuwenhuis Edward ES

    2011-10-01

    Full Text Available Abstract Background Child abuse and neglect is an important international health problem with unacceptable levels of morbidity and mortality. Although maltreatment as a cause of injury is estimated to be only 1% or less of the injured children attending the emergency room, the consequences of both missed child abuse cases and wrong suspicions are substantial. Therefore, the accuracy of ongoing detection at emergency rooms by health care professionals is highly important. Internationally, several diagnostic instruments or strategies for child abuse detection are used at emergency rooms, but their diagnostic value is still unknown. The aim of the study 'Child Abuse Inventory at Emergency Rooms' (CHAIN-ER is to assess if active structured inquiry by emergency room staff can accurately detect physical maltreatment in children presenting at emergency rooms with physical injury. Methods/design CHAIN-ER is a multi-centre, cross-sectional study with 6 months diagnostic follow-up. Five thousand children aged 0-7 presenting with injury at an emergency room will be included. The index test - the SPUTOVAMO-R questionnaire- is to be tested for its diagnostic value against the decision of an expert panel. All SPUTOVAMO-R positives and a 15% random sample of the SPUTOVAMO-R negatives will undergo the same systematic diagnostic work up, which consists of an adequate history being taken by a pediatrician, inquiry with other health care providers by structured questionnaires in order to obtain child abuse predictors, and by additional follow-up information. Eventually, an expert panel (reference test determines the true presence or absence of child abuse. Discussion CHAIN-ER will determine both positive and negative predictive value of a child abuse detection instrument used in the emergency room. We mention a benefit of the use of an expert panel and of the use of complete data. Conducting a diagnostic accuracy study on a child abuse detection instrument is also

  15. Procedure and information displays in advanced nuclear control rooms: experimental evaluation of an integrated design.

    Science.gov (United States)

    Chen, Yue; Gao, Qin; Song, Fei; Li, Zhizhong; Wang, Yufan

    2017-08-01

    In the main control rooms of nuclear power plants, operators frequently have to switch between procedure displays and system information displays. In this study, we proposed an operation-unit-based integrated design, which combines the two displays to facilitate the synthesis of information. We grouped actions that complete a single goal into operation units and showed these operation units on the displays of system states. In addition, we used different levels of visual salience to highlight the current unit and provided a list of execution history records. A laboratory experiment, with 42 students performing a simulated procedure to deal with unexpected high pressuriser level, was conducted to compare this design against an action-based integrated design and the existing separated-displays design. The results indicate that our operation-unit-based integrated design yields the best performance in terms of time and completion rate and helped more participants to detect unexpected system failures. Practitioner Summary: In current nuclear control rooms, operators frequently have to switch between procedure and system information displays. We developed an integrated design that incorporates procedure information into system displays. A laboratory study showed that the proposed design significantly improved participants' performance and increased the probability of detecting unexpected system failures.

  16. HPGe detector shielding adjustment

    International Nuclear Information System (INIS)

    Trnkova, L.; Rulik, P.

    2008-01-01

    Low-level background shielding of HPGe detectors is used mainly for environmental samples with very low content of radionuclides. National Radiation Protection Institute (SURO) in Prague is equipped with 14 HPGe detectors with relative efficiency up to 150%. The detectors are placed in a room built from materials with low content of natural radionuclides and equipped with a double isolation of the floor against radon. Detectors themselves are placed in lead or steel shielding. Steel shielding with one of these detectors with relative efficiency of 100% was chosen to be rebuilt to achieve lower minimum detectable activity (MDA). Additional lead and copper shielding was built up inside the original steel shielding to reduce the volume of the inner space and filled with nitrogen by means of evaporating liquid nitrogen. The additional lead and copper shielding, consequent reduction of the inner volume and supply of evaporated nitrogen, caused a decrease of the background count and accordingly MDA values as well. The effect of nitrogen evaporation on the net areas of peaks belonging to radon daughters is significant. The enhanced shielding adjustment has the biggest influence in low energy range, what can be seen in collected data. MDA values in energy range from 30 keV to 400 keV decreased to 0.65-0.85 of original value, in energy range from 400 keV to 2 MeV they fell to 0.70-0.97 of original value. (authors)

  17. Calculation of the structural shielding of the radiotherapy treatment room equipped with a linear accelerator type Tomo therapy Hi-Art in the Oncology Center of Chihuahua, Mexico

    International Nuclear Information System (INIS)

    Caballero G, C. A.; Plascencia, J. C.; Vargas V, M. X.; Toledo J, P.

    2010-09-01

    The helicoid tomo therapy is an external radiotherapy system of modulated intensity, guided by image, in which the radiation is imparted to the patient using a narrow radiation beam in helicoid form, in a similar way to the scanning process with a computerized tomography. The tomo therapy equipment (Tomo Therapy Hi-Art) consists in an electrons linear accelerator with acceleration voltages of 6 MV for treatment and 3.5 MV for image, coupled to a ring that turn around the patient as this is transferred through this ring in perpendicular sense to the radiation beam. The radiation beam is narrow because has the maximum size of 5 x 40 cm 2 in the isocenter. The intensity modulation of the beam is carried out with a binary dynamic collimator of 64 crisscross sheets, and the guide by image though a system of megavoltage computerized tomography. Opposed to the radiation beam, also coupled to the rotational ring, a group of lead plates exists with a total thickness of 13 cm that acts as barrier of the primary radiation beam. The special configuration of the tomography equipment makes to have the following characteristics: 1) the presence of the lead barrier of the equipment reduces the intensity of the primary beam that reaches the bunker walls in considerable way, 2) the disperse and leakage radiations are increased with regard to a conventional accelerator due to the increase in the necessary irradiation time to produce modulated intensity fields by means of the narrow radiation beam. These special characteristics of the tomo therapy equipment make that particularities exist in the application of the formulations for structural shielding calculations that appears in the NCRP reports 49, NCRP 151 and IAEA-SRS-47. For this reason, several researches have development analytic models based on geometric considerations of continuous rotation of the equipment ring to determine the shielding requirements for the primary beam, the dispersed and leakage radiation in tomo therapy

  18. Educational Gaming for Pharmacy Students - Design and Evaluation of a Diabetes-themed Escape Room.

    Science.gov (United States)

    Eukel, Heidi N; Frenzel, Jeanne E; Cernusca, Dan

    2017-09-01

    Objective. To design an educational game that will increase third-year professional pharmacy students' knowledge of diabetes mellitus disease management and to evaluate their perceived value of the game. Methods. Faculty members created an innovative educational game, the diabetes escape room. An authentic escape room gaming environment was established through the use of a locked room, an escape time limit, and game rules within which student teams completed complex puzzles focused on diabetes disease management. To evaluate the impact, students completed a pre-test and post-test to measure the knowledge they've gained and a perception survey to identify moderating factors that could help instructors improve the game's effectiveness and utility. Results. Students showed statistically significant increases in knowledge after completion of the game. A one-sample t -test indicated that students' mean perception was statistically significantly higher than the mean value of the evaluation scale. This statically significant result proved that this gaming act offers a potential instructional benefit beyond its novelty. Conclusion. The diabetes escape room proved to be a valuable educational game that increased students' knowledge of diabetes mellitus disease management and showed a positive perceived overall value by student participants.

  19. Use of ROOM in the design of data-acquisition software components

    CERN Document Server

    Carena, W; Van de Vyvre, P; Vascotto, Alessandro

    1999-01-01

    Presentation made at the Real Time Conference, Santa Fe, New Mexico 14-18 June 1999The Event Builder and Distribution System (EBDS) is a component of the data-acquisition architecture of the ALICE experiment at CERN. The purpose of the EBDS is to dispatch the sub-events originated in the detector front-end electronics to the processors of the Event Filter Farm, where the full events are assembled.For the design of the EBDS, we use the Real-time Object-Oriented Modelling method (ROOM), which was chosen because of its powerful modelling paradigm, well suited to this type of application. The use of ROOM is aided by the ObecTime Developer tool set, which fully supports the method and covers all the aspects of the development cycle, from analysis to code generation. Fast prototyping and simulation bring a new perspective to the designer, who can advance by gradual refinements.We describe how ROOM has been used to design a model of both the EBDS and its environment, and the results obtained from the simulation. We ...

  20. The ITER EC H&CD upper launcher: Design, analysis and testing of a bolted joint for the Blanket Shield Module

    NARCIS (Netherlands)

    Gessner, R.; Aiello, G.; Grossetti, G.; Meier, A.; Ronden, D.; Spaeh, P.; Scherer, T.; Schreck, S.; Strauss, D.; Vaccaro, A.

    2013-01-01

    The final design of the structural system for the ITER EC H&CD upper launcher is in progress. Many design features of the preliminary design are under revision with the aim to achieve the built-to-print-status. This paper deals with design and analysis of a bolted joint for the Blanket Shield

  1. Electromagnetic shielding

    International Nuclear Information System (INIS)

    Tzeng, Wen-Shian V.

    1991-01-01

    Electromagnetic interference (EMI) shielding materials are well known in the art in forms such as gaskets, caulking compounds, adhesives, coatings and the like for a variety of EMI shielding purposes. In the past, where high shielding performance is necessary, EMI shielding has tended to use silver particles or silver coated copper particles dispersed in a resin binder. More recently, aluminum core silver coated particles have been used to reduce costs while maintaining good electrical and physical properties. (author). 8 figs

  2. Human factors design of nuclear power plant control rooms including computer-based operator aids

    International Nuclear Information System (INIS)

    Bastl, W.; Felkel, L.; Becker, G.; Bohr, E.

    1983-01-01

    The scientific handling of human factors problems in control rooms began around 1970 on the basis of safety considerations. Some recent research work deals with the development of computerized systems like plant balance calculation, safety parameter display, alarm reduction and disturbance analysis. For disturbance analysis purposes it is necessary to homogenize the information presented to the operator according to the actual plant situation in order to supply the operator with the information he most urgently needs at the time. Different approaches for solving this problem are discussed, and an overview is given on what is being done. Other research projects concentrate on the detailed analysis of operators' diagnosis strategies in unexpected situations, in order to obtain a better understanding of their mental processes and the influences upon them when such situations occur. This project involves the use of a simulator and sophisticated recording and analysis methods. Control rooms are currently designed with the aid of mock-ups. They enable operators to contribute their experience to the optimization of the arrangement of displays and controls. Modern control rooms are characterized by increasing use of process computers and CRT (Cathode Ray Tube) displays. A general concept for the integration of the new computerized system and the conventional control panels is needed. The technical changes modify operators' tasks, and future ergonomic work in nuclear plants will need to consider the re-allocation of function between man and machine, the incorporation of task changes in training programmes, and the optimal design of information presentation using CRTs. Aspects of developments in control room design are detailed, typical research results are dealt with, and a brief forecast of the ergonomic contribution to be made in the Federal Republic of Germany is given

  3. Evaluation of the shield calculation adequacy of radiotherapy rooms through Monte Carlo Method and experimental measures; Avaliacao da adequacao do calculo de blindagens de salas de radioterapia atraves do metodo de Monte Carlos e medidas experimentais

    Energy Technology Data Exchange (ETDEWEB)

    Meireles, Ramiro Conceicao

    2016-07-01

    The shielding calculation methodology for radiotherapy services adopted in Brazil and in several countries is that described in publication 151 of the National Council on Radiation Protection and Measurements (NCRP 151). This methodology however, markedly employs several approaches that can impact both in the construction cost and in the radiological safety of the facility. Although this methodology is currently well established by the high level of use, some parameters employed in the calculation methodology did not undergo to a detailed assessment to evaluate the impact of the various approaches considered. In this work the MCNP5 Monte Carlo code was used with the purpose of evaluating the above mentioned approaches. TVLs values were obtained for photons in conventional concrete (2.35g / cm{sup 3}), considering the energies of 6, 10 and 25 MeV, respectively, first considering an isotropic radiation source impinging perpendicular to the barriers, and subsequently a lead head shielding emitting a shaped beam, in the format of a pyramid trunk. Primary barriers safety margins, taking in account the head shielding emitting photon beam pyramid-shaped in the energies of 6, 10, 15 and 18 MeV were assessed. A study was conducted considering the attenuation provided by the patient's body in the energies of 6,10, 15 and 18 MeV, leading to new attenuation factors. Experimental measurements were performed in a real radiotherapy room, in order to map the leakage radiation emitted by the accelerator head shielding and the results obtained were employed in the Monte Carlo simulation, as well as to validate the entire study. The study results indicate that the TVLs values provided by (NCRP, 2005) show discrepancies in comparison with the values obtained by simulation and that there may be some barriers that are calculated with insufficient thickness. Furthermore, the simulation results show that the additional safety margins considered when calculating the width of the

  4. Human factors review of nuclear power plant control room design. Final report

    International Nuclear Information System (INIS)

    Seminara, J.L.; Gonzalez, W.R.; Parsons, S.O.

    1976-11-01

    The human factors aspects of five representative nuclear power plant control rooms were evaluated using such methods as a checklist guided observation system, structured interviews with operators and trainers, direct observations of operator behavior, task analyses and procedure evaluation, and historical error analyses. The human factors aspects of design practices are illustrated, and many improvements in current practices are suggested. The study recommends that a detailed set of applicable human factors standards be developed to stimulate a uniform and systematic concern for human factors in design considerations

  5. DHM simulation in virtual environments: a case-study on control room design.

    Science.gov (United States)

    Zamberlan, M; Santos, V; Streit, P; Oliveira, J; Cury, R; Negri, T; Pastura, F; Guimarães, C; Cid, G

    2012-01-01

    This paper will present the workflow developed for the application of serious games in the design of complex cooperative work settings. The project was based on ergonomic studies and development of a control room among participative design process. Our main concerns were the 3D human virtual representation acquired from 3D scanning, human interaction, workspace layout and equipment designed considering ergonomics standards. Using Unity3D platform to design the virtual environment, the virtual human model can be controlled by users on dynamic scenario in order to evaluate the new work settings and simulate work activities. The results obtained showed that this virtual technology can drastically change the design process by improving the level of interaction between final users and, managers and human factors team.

  6. Collimator and shielding design for boron neutron capture therapy (BNCT) facility at TRIGA MARK II reactor

    International Nuclear Information System (INIS)

    Mohd Rafi Mohd Solleh; Abdul Aziz Tajuddin; Abdul Aziz Mohamed; Eid Mahmoud Eid Abdel Munem; Mohamad Hairie Rabir; Julia Abdul Karim; Yoshiaki, Kiyanagi

    2011-01-01

    The geometry of reactor core, thermal column, collimator and shielding system for BNCT application of TRIGA MARK II Reactor were simulated with MCNP5 code. Neutron particle lethargy and dose were calculated with MCNPX code. Neutron flux in a sample located at the end of collimator after normalized to measured value (Eid Mahmoud Eid Abdel Munem, 2007) at 1 MW power was 1.06 x 10 8 n/ cm 2 / s. According to IAEA (2001) flux of 1.00 x 10 9 n/ cm 2 / s requires three hours of treatment. Few modifications were needed to get higher flux. (Author)

  7. The implications of ICRP publication 74 for the design of the LHC shielding

    International Nuclear Information System (INIS)

    Stevenson, G.R.

    1997-01-01

    A joint committee of the International Commission on Radiological Protection (ICRP) and the International Commission on Radiation Units and Measurements (ICRU) have recently published a report recommending new factors for the conversion of the fluence of neutrons, photons and electrons into radiologically significant quantities. Both the quantities specified and the numerical values of the conversion coefficients are different from previously published values. This report investigates the effect of these changes on the predictions of shielding requirements for the LHC and suggests that only minor policy adjustments are necessary. (author)

  8. Guidelines for beamline and front-end radiation shielding design at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Fernandez, P.; X-Ray Science Division

    2008-01-01

    Shielding for the APS will be such that the individual radiation worker dose will be as low as reasonably achievable (ALARA). The ALARA goals for the APS are to keep the total of the work-related radiation exposure (exposure coming from other than natural or medical sources) as far below 500 person-mrem per year, collective total effective dose equivalent, as reasonably achievable. For an individual APS radiation worker, the goal is to keep the maximum occupational total effective dose equivalent of any one employee as far below 200 mrem/yr as reasonably achievable. The ALARA goal for APS beamline scientists is to keep the total of the work-related radiation exposure (exposure coming from other than natural or medical sources) as far below 100 person-mrem per year, collective total effective dose equivalent, as reasonably achievable. For an individual APS beamline scientist, the goal is to keep the maximum occupational total effective dose equivalent of any one scientist as far below 50 mrem/yr as reasonably achievable. The dose is actively monitored by the radiation monitors on the storage ring wall in each sector and by the frequent area surveys performed by the health physics personnel. For cases in which surveys indicate elevated hourly dose rates that may impact worker exposure, additional local shielding is provided to reduce the radiation field to an acceptable level. Passive area monitors are used throughout the facility to integrate doses in various areas. The results are analyzed for trends of increased doses, and shielding in these areas is evaluated and improved, as appropriate. The APS policy for on-site nonradiation workers in the vicinity of the APS facilities requires that the average nonradiation worker dose be below 0.2 mSv/yr (20 mrem/yr). In addition, the dose at the site boundary from all pathways is required to be below 0.1 mSv/yr (10 mrem/yr). For future modifications of the facility, the doses shall be evaluated and additional shielding

  9. Workers radiation protection. Solutions accommodate new needs. The tool box of radiation protection expands itself. Industrial radiology: workers aware of risks. To design a shielded enclosure

    International Nuclear Information System (INIS)

    Rannou, Alain; Billarand, Yann; Scanff, Pascale; Etard, Cecile; Sage, Julie; Jolivet, Patrick; Israel, Sylvain; Caplin, Helene; Couasnon, Olivier; Cordelle, Anne

    2017-01-01

    A first article proposes an overview of developments in the field of workers radiation protection. This development is notably motivated by the future dismantling works. It can be noticed that some other issues are considered as more important than radiation protection in the medical field even though radiation protection is a matter of concern for radiology manipulators. Radiation protection is also an issue for workers performing luggage X-ray controls in airports. As revealed by some measurements, artificial radioactivity should be controlled. Radiation protection is planned in relationship with an exposure scenario. The Belgium example is evoked with the development of centralised data and statistics in order to compare workers profiles. A second article comments the evolution of the activity of radiation protection with its new documents, methodologies (notably for operating rooms), and practical studies. While indicating how much the number of specialised workers increased, and how much dose control has been developed in the medical sector, and in terms of workers wearing a ring- or wrist-dosimeter between 2006 and 2015, and also indicating the distribution of controlled workers among sectors, the article outlines that a computation tool is shared between professionals, and how sheets on radionuclides are published and shared. The third article briefly addresses industrial radiology to outlines that workers are always more aware of risks. The last article briefly describes how a shielded enclosure is designed to limit workers exposure

  10. Designing switchable near room-temperature multiferroics via the discovery of a novel magnetoelectric coupling

    Science.gov (United States)

    Feng, J. S.; Xu, Ke; Bellaiche, Laurent; Xiang, H. J.

    2018-05-01

    Magnetoelectric (ME) coupling is the key ingredient for realizing the cross-control of magnetism and ferroelectricity in multiferroics. However, multiferroics are not only rare, especially at room-temperature, in nature but also the overwhelming majority of known multiferroics do not exhibit highly-desired switching of the direction of magnetization when the polarization is reversed by an electric field. Here, we report group theory analysis and ab initio calculations demonstrating, and revealing the origin of, the existence of a novel form of ME coupling term in a specific class of materials that does allow such switching. This term naturally explains the previously observed electric field control of magnetism in the first known multiferroics, i.e., the Ni–X boracite family. It is also presently used to design a switchable near room-temperature multiferroic (namely, LaSrMnOsO6 perovskite) having rather large ferroelectric polarization and spontaneous magnetization, as well as strong ME coupling.

  11. Design and Validation of Control Room Upgrades Using a Research Simulator Facility

    Energy Technology Data Exchange (ETDEWEB)

    Ronald L. Boring; Vivek Agarwal; Jeffrey C. Joe; Julius J. Persensky

    2012-11-01

    Since 1981, the United States (U.S.) Nuclear Regulatory Commission (NRC) [1] requires a plant- specific simulator facility for use in training at U.S. nuclear power plants (NPPs). These training simulators are in near constant use for training and qualification of licensed NPP operators. In the early 1980s, the Halden Man-Machine Laboratory (HAMMLab) at the Halden Reactor Project (HRP) in Norway first built perhaps the most well known set of research simulators. The HRP offered a high- fidelity simulator facility in which the simulator is functionally linked to a specific plant but in which the human-machine interface (HMI) may differ from that found in the plant. As such, HAMMLab incorporated more advanced digital instrumentation and controls (I&C) than the plant, thereby giving it considerable interface flexibility that researchers took full advantage of when designing and validating different ways to upgrade NPP control rooms. Several U.S. partners—the U.S. NRC, the Electrical Power Research Institute (EPRI), Sandia National Laboratories, and Idaho National Laboratory (INL) – as well as international members of the HRP, have been working with HRP to run control room simulator studies. These studies, which use crews from Scandinavian plants, are used to determine crew behavior in a variety of normal and off-normal plant operations. The findings have ultimately been used to guide safety considerations at plants and to inform advanced HMI design—both for the regulator and in industry. Given the desire to use U.S. crews of licensed operators on a simulator of a U.S. NPP, there is a clear need for a research simulator facility in the U.S. There is no general-purpose reconfigurable research oriented control room simulator facility in the U.S. that can be used for a variety of studies, including the design and validation of control room upgrades.

  12. Design and Development of a Relative Humidity and Room Temperature Measurement System with On Line Data Logging Feature for Monitoring the Fermentation Room of Tea Factory

    Directory of Open Access Journals (Sweden)

    Utpal SARMA

    2011-12-01

    Full Text Available The design and development of a Relative Humidity (RH and Room Temperature (RT monitoring system with on line data logging feature for monitoring fermentation room of a tea factory is presented in this paper. A capacitive RH sensor with on chip signal conditioner is taken as RH sensor and a temperature to digital converter (TDC is used for ambient temperature monitoring. An 8051 core microcontroller is the heart of the whole system which reads the digital equivalent of RH data with the help of a 12-bit Analog to Digital (A/D converter and synchronize TDC to get the ambient temperature. The online data logging is achieved with the help of RS-232C communication. Field performance is also studied by installing it in the fermentation room of a tea factory.

  13. Performance of the improved version of Monte Carlo Code A3MCNP for cask shielding design

    International Nuclear Information System (INIS)

    Hasegawa, T.; Ueki, K.; Sato, O.; Sjoden, G.E.; Miyake, Y.; Ohmura, M.; Haghighat, A.

    2004-01-01

    A 3 MCNP (Automatic Adjoint Accelerated MCNP) is a revised version of the MCNP Monte Carlo code, that automatically prepares variance reduction parameters for the CADIS (Consistent Adjoint Driven Importance Sampling) methodology. Using a deterministic ''importance'' (or adjoint) function, CADIS performs source and transport biasing within the weight-window technique. The current version of A 3 MCNP uses the 3-D Sn transport TORT code to determine a 3-D importance function distribution. Based on simulation of several real-life problems, it is demonstrated that A3MCNP provides precise calculation results with a remarkably short computation time by using the proper and objective variance reduction parameters. However, since the first version of A 3 MCNP provided only a point source configuration option for large-scale shielding problems, such as spent-fuel transport casks, a large amount of memory may be necessary to store enough points to properly represent the source. Hence, we have developed an improved version of A 3 MCNP (referred to as A 3 MCNPV) which has a volumetric source configuration option. This paper describes the successful use of A 3 MCNPV for cask neutron and gamma-ray shielding problem

  14. SHIELD 1.0: development of a shielding calculator program in diagnostic radiology; SHIELD 1.0: desenvolvimento de um programa de calculo de blindagem em radiodiagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Romulo R.; Real, Jessica V.; Luz, Renata M. da [Hospital Sao Lucas (PUCRS), Porto Alegre, RS (Brazil); Friedrich, Barbara Q.; Silva, Ana Maria Marques da, E-mail: ana.marques@pucrs.br [Pontificia Universidade Catolica do Rio Grande do Sul (PUCRS), Porto Alegre, RS (Brazil)

    2013-08-15

    In shielding calculation of radiological facilities, several parameters are required, such as occupancy, use factor, number of patients, source-barrier distance, area type (controlled and uncontrolled), radiation (primary or secondary) and material used in the barrier. The shielding design optimization requires a review of several options about the physical facility design and, mainly, the achievement of the best cost-benefit relationship for the shielding material. To facilitate the development of this kind of design, a program to calculate the shielding in diagnostic radiology was implemented, based on data and limits established by National Council on Radiation Protection and Measurements (NCRP) 147 and SVS-MS 453/98. The program was developed in C⌗ language, and presents a graphical interface for user data input and reporting capabilities. The module initially implemented, called SHIELD 1.0, refers to calculating barriers for conventional X-ray rooms. The program validation was performed by the comparison with the results of examples of shielding calculations presented in NCRP 147.

  15. Shielding experiments for accelerator facilities

    Energy Technology Data Exchange (ETDEWEB)

    Nakashima, Hiroshi; Tanaka, Susumu; Sakamoto, Yukio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment] [and others

    2000-06-01

    A series of shielding experiments was carried out by using AVF cyclotron accelerator of TIARA at JAERI in order to validate shielding design methods for accelerator facilities in intermediate energy region. In this paper neutron transmission experiment through thick shields and radiation streaming experiment through a labyrinth are reported. (author)

  16. Shielding experiments for accelerator facilities

    International Nuclear Information System (INIS)

    Nakashima, Hiroshi; Tanaka, Susumu; Sakamoto, Yukio

    2000-01-01

    A series of shielding experiments was carried out by using AVF cyclotron accelerator of TIARA at JAERI in order to validate shielding design methods for accelerator facilities in intermediate energy region. In this paper neutron transmission experiment through thick shields and radiation streaming experiment through a labyrinth are reported. (author)

  17. Radiation physics and shielding codes and analyses applied to design-assist and safety analyses of CANDUR and ACRTM reactors

    International Nuclear Information System (INIS)

    Aydogdu, K.; Boss, C. R.

    2006-01-01

    This paper discusses the radiation physics and shielding codes and analyses applied in the design of CANDU and ACR reactors. The focus is on the types of analyses undertaken rather than the inputs supplied to the engineering disciplines. Nevertheless, the discussion does show how these analyses contribute to the engineering design. Analyses in radiation physics and shielding can be categorized as either design-assist or safety and licensing (accident) analyses. Many of the analyses undertaken are designated 'design-assist' where the analyses are used to generate recommendations that directly influence plant design. These recommendations are directed at mitigating or reducing the radiation hazard of the nuclear power plant with engineered systems and components. Thus the analyses serve a primary safety function by ensuring the plant can be operated with acceptable radiation hazards to the workers and public. In addition to this role of design assist, radiation physics and shielding codes are also deployed in safety and licensing assessments of the consequences of radioactive releases of gaseous and liquid effluents during normal operation and gaseous effluents following accidents. In the latter category, the final consequences of accident sequences, expressed in terms of radiation dose to members of the public, and inputs to accident analysis, e.g., decay heat in fuel following a loss-of-coolant accident, are also calculated. Another role of the analyses is to demonstrate that the design of the plant satisfies the principle of ALARA (as low as reasonably achievable) radiation doses. This principle is applied throughout the design process to minimize worker and public doses. The principle of ALARA is an inherent part of all design-assist recommendations and safety and licensing assessments. The main focus of an ALARA exercise at the design stage is to minimize the radiation hazards at the source. This exploits material selection and impurity specifications and relies

  18. Design and construction of the clean room for proton beam accelerator assembly

    Energy Technology Data Exchange (ETDEWEB)

    Park, J. S.; Song, I. T

    2000-09-01

    The objective of this report is to design, construction and evaluation of clean room for proton beam accelerator assembly. The design conditions o Class : 1,000(1,000 ea ft{sup 3}), o Flow Rate : 200 m{sup 3}/h m{sup 2}, o Temperature : 22 deg C{+-}2, o Humidity : 55%{+-}5. The main design results are summarized as follows: o Air-handling unit : Cooling Capacity : 13,500 kcal/h, Heating Capacity : 10,300 kcal/h, Humidity Capacity : 4 kg/h, Flow Rate : 150 CMM o Air Shower : Flow Rate : 35 CMM, Size : 1500 x 1000 x 2200, Material : In-steel, Out-SUS304, Filter : PRE + HEPA, AIR Velocity : 25 m/s o Relief Damper : Size : {phi}250, Casing : SS41, Blade : AL, Shaft : SUS304, Weight Ring : SS41, Grill : AL o HEPA Filter Box : Filter Box Size : 670 x 670 x 630, Filter Size : 610 x 610 x 150, Frame: Poly Wood, Media : Glass Fiber, Filter Efficiency : 0.3{mu}m, 99.97%, Separator : AL, Flow Rate : 17 CMM, Damper Size : {phi}300 Following this report will be used important data for the design, construction, operation and maintenance of the clean room, for high precision apparatus assembly laboratory.

  19. Design and construction of the clean room for proton beam accelerator assembly

    International Nuclear Information System (INIS)

    Park, J. S.; Song, I. T.

    2000-09-01

    The objective of this report is to design, construction and evaluation of clean room for proton beam accelerator assembly. The design conditions o Class : 1,000(1,000 ea ft 3 ), o Flow Rate : 200 m 3 /h m 2 , o Temperature : 22 deg C±2, o Humidity : 55%±5. The main design results are summarized as follows: o Air-handling unit : Cooling Capacity : 13,500 kcal/h, Heating Capacity : 10,300 kcal/h, Humidity Capacity : 4 kg/h, Flow Rate : 150 CMM o Air Shower : Flow Rate : 35 CMM, Size : 1500 x 1000 x 2200, Material : In-steel, Out-SUS304, Filter : PRE + HEPA, AIR Velocity : 25 m/s o Relief Damper : Size : Φ250, Casing : SS41, Blade : AL, Shaft : SUS304, Weight Ring : SS41, Grill : AL o HEPA Filter Box : Filter Box Size : 670 x 670 x 630, Filter Size : 610 x 610 x 150, Frame: Poly Wood, Media : Glass Fiber, Filter Efficiency : 0.3μm, 99.97%, Separator : AL, Flow Rate : 17 CMM, Damper Size : Φ300 Following this report will be used important data for the design, construction, operation and maintenance of the clean room, for high precision apparatus assembly laboratory

  20. Development of a computer code for determining the thickness of shielding used in cardiac angiography techniques

    International Nuclear Information System (INIS)

    Lava, Deise D.; Borges, Diogo da S.; Affonso, Renato R.W.; Moreira, Maria de L.; Guimaraes, Antonio C.F.

    2014-01-01

    The construction of an effective shielding against the interaction of ionizing radiation in X-ray rooms requires consideration of many variables. The methodology used for specification of a primary and secondary shielding thickness of a X-ray room considers the following factors: use factor, occupational factor, distance between the source and the wall, workload, Kerma in the air and distance between the patient and the receptor. The program built from this data, has the objective of identifying and using variables in functions obtained through linear regressions of graphics offered by NCRP Report-147 (Structural Shielding Design for Medical X-Ray Imaging Facilities) for the shielding calculation of the room walls as wall dark room and adjacent areas. With the methodology constructed a program validation is done by comparison of results with a base case provided by that report. The values of the thicknesses obtained comprise various materials such as steel, wood and concrete. Once validated an application is made in a real case of X-ray room. His visual construction is done with the help of software used in modeling of interiors and exteriors. The construction of shielding calculating program has the goal of being an easy tool for planning of X-ray rooms in order to meet the established limits by CNEN-NN-3:01 published in September 2011

  1. Human factors verification and validation of the advanced nuclear plant control room design

    International Nuclear Information System (INIS)

    Gutierrez, Richard; Zizzo, David; Yu, Kim

    2005-01-01

    The GE Advanced Boiling Water Reactor (ABWR) design has implemented the applicable human factors engineering (HFE) principles in the design of human-system interfaces (HSI). The ABWR uses unique features such as large mimic and touch-screen technology to present plant overviews and system operating details to the control room operating staff. The HSI designs, both in the console panels and the software generated graphical user interfaces, have been developed and evaluated using HFE guidelines. In addition to HFE guidelines reviews performed during design and implementation, broader reviews have been performed under the HFE Verification and Validation Implementation Plan (HFE V and VIP). Based upon the NUREG-0711, Nuclear Regulatory Commission (NRC) HFE Program Review Model (HFE PRM) (Reference 1), the HFE V and VIP, hereafter also referred to as V and V, has provided feedback during the various phases of design, implementation, and integration of the HSI. As one of the ten elements of the HFE PRM, the V and V activities reaffirm that the design of the HSI conforms to the HFE design principles and that the plant operating staff in the control room can perform their assigned tasks. This rigorous HFE V and V process is now being applied in the implementation of the ABWR design for Taiwan Power Company's Lungmen Power Station. Two 1350 MWe ABWR units are currently under construction at Lungmen. The HFE V and V ensures that the process for the design is compliant with the HFE principles. An important aspect of the Lungmen HFE program has been the direct involvement of the end user, Taiwan Power Company (TPC), throughout the design development and implementation. These HFE V and V activities, performed in three phases, ensures that the necessary displays, control, and alarms are provided to support the identified personnel tasks. The HFE V and V also checks to determine that the design of each identified component is compliant with the HFE principles. The V and V ensures

  2. Vision-based overlay of a virtual object into real scene for designing room interior

    Science.gov (United States)

    Harasaki, Shunsuke; Saito, Hideo

    2001-10-01

    In this paper, we introduce a geometric registration method for augmented reality (AR) and an application system, interior simulator, in which a virtual (CG) object can be overlaid into a real world space. Interior simulator is developed as an example of an AR application of the proposed method. Using interior simulator, users can visually simulate the location of virtual furniture and articles in the living room so that they can easily design the living room interior without placing real furniture and articles, by viewing from many different locations and orientations in real-time. In our system, two base images of a real world space are captured from two different views for defining a projective coordinate of object 3D space. Then each projective view of a virtual object in the base images are registered interactively. After such coordinate determination, an image sequence of a real world space is captured by hand-held camera with tracking non-metric measured feature points for overlaying a virtual object. Virtual objects can be overlaid onto the image sequence by taking each relationship between the images. With the proposed system, 3D position tracking device, such as magnetic trackers, are not required for the overlay of virtual objects. Experimental results demonstrate that 3D virtual furniture can be overlaid into an image sequence of the scene of a living room nearly at video rate (20 frames per second).

  3. Radiation shielding calculation for the MOX fuel fabrication plant Melox

    International Nuclear Information System (INIS)

    Lee, Y.K.; Nimal, J.C.; Chiron, M.

    1994-01-01

    Radiation shielding calculation is an important engineering work in the design of the MOX fuel fabrication plant MELOX. Due to the recycle of plutonium and uranium from UO2 spent fuel reprocessing and the large capacity of production (120t HM/yr.), the shielding design requires more attention in this LWR fuel plant. In MELOX, besides several temporary storage facilities of massive fissile material, about one thousand radioactive sources with different geometries, forms, densities, quantities and Pu concentrations, are distributed through different workshops from the PuO 2 powder reception unit to the fuel assembly packing room. These sources, with or without close shield, stay temporarily in different locations, containers and glove boxes. In order to optimize the dimensions, the material and the cost of shield as well as to limit the calculation work in a reasonable engineer-hours, a calculation scheme for shielding design of MELOX is developed. This calculation scheme has been proved to be useful in consideration of the feedback from the evolutionary design and construction. The validated shielding calculations give a predictive but reliable radiation doses information. (authors). 2 figs., 10 refs

  4. Shielding plugs

    International Nuclear Information System (INIS)

    Makishima, Kenji.

    1986-01-01

    Purpose: In shielding plugs of an LMFBR type reactor, to restrain natural convection of heat in an annular space between a thermal shield layer and a shield shell, to prevent the lowering of heat-insulation performance, and to alleviate a thermal stress in a reactor container and the shield shell. Constitution: A ring-like leaf spring split in the direction of height is disposed in an annular space between a thermal shield layer and a shield shell. In consequence, the space is partitioned in the direction of height and, therefore, if axial temperature conditions and space width are the same and the space is low, the natural convection is hard to occur. Thus the rise of upper surface temperature of the shielding plugs can prevent the lowering of the heat insulation performance which will result in the increment of shielding plug cooling capacity, thereby improving reliability. In the meantime, since there is mounted an earthquake-resisting support, the thermal shield layer will move for a slight gap in case of an earthquake, being supported by the earthquake-resisting support, and the movement of the thermal shield layer is restricted, thereby maintaining integrity without increasing the stroke of the ring-like spring. (Kawakami, Y.)

  5. Evaluation of RayXpert® for shielding design of medical facilities

    Science.gov (United States)

    Derreumaux, Sylvie; Vecchiola, Sophie; Geoffray, Thomas; Etard, Cécile

    2017-09-01

    In a context of growing demands for expert evaluation concerning medical, industrial and research facilities, the French Institute for radiation protection and nuclear safety (IRSN) considered necessary to acquire new software for efficient dimensioning calculations. The selected software is RayXpert®. Before using this software in routine, exposure and transmission calculations for some basic configurations were validated. The validation was performed by the calculation of gamma dose constants and tenth value layers (TVL) for usual shielding materials and for radioisotopes most used in therapy (Ir-192, Co-60 and I-131). Calculated values were compared with results obtained using MCNPX as a reference code and with published values. The impact of different calculation parameters, such as the source emission rays considered for calculation and the use of biasing techniques, was evaluated.

  6. Conceptual radiation shielding design of superconducting tokamak fusion device by PHITS

    International Nuclear Information System (INIS)

    Sukegawa, Atsuhiko M.; Kawasaki, Hiromitsu; Okuno, Koichi

    2010-01-01

    A complete 3D neutron and photon transport analysis by Monte Carlo transport code system PHITS (Particle and Heavy Ion Transport code System) have been performed for superconducting tokamak fusion device such as JT-60 Super Advanced (JT-60SA). It is possible to make use of PHITS in the port streaming analysis around the devices for the tokamak fusion device, the duct streaming analysis in the building where the device is installed, and the sky shine analysis for the site boundary. The neutron transport analysis by PHITS makes it clear that the shielding performance of the superconducting tokamak fusion device with the cryostat is improved by the graphical results. From the standpoint of the port streaming and the duct streaming, it is necessary to calculate by 3D Monte Carlo code such as PHITS for the neutronics analysis of superconducting tokamak fusion device. (author)

  7. Calculation of neutron and gamma ray energy spectra for fusion reactor shield design: comparison with experiment

    International Nuclear Information System (INIS)

    Santoro, R.T.; Alsmiller, R.G. Jr.; Barnes, J.M.; Chapman, G.T.

    1980-08-01

    Integral experiments that measure the transport of approx. 14 MeV D-T neutrons through laminated slabs of proposed fusion reactor shield materials have been carried out. Measured and calculated neutron and gamma ray energy spectra are compared as a function of the thickness and composition of stainless steel type 304, borated polyethylene, and Hevimet (a tungsten alloy), and as a function of detector position behind these materials. The measured data were obtained using a NE-213 liquid scintillator using pulse-shape discrimination methods to resolve neutron and gamma ray pulse height data and spectral unfolding methods to convert these data to energy spectra. The calculated data were obtained using two-dimensional discrete ordinates radiation transport methods in a complex calculational network that takes into account the energy-angle dependence of the D-T neutrons and the nonphysical anomalies of the S/sub n/ method

  8. Use of polyethylene pellets in the design and construction of a storage safe, a transport vessel and a portable shield for californium-252

    International Nuclear Information System (INIS)

    Sharma, S.

    1986-01-01

    A storage and shielding facility for 300 μg of Californium-252 sources was designed and constructed. Though the safe was in a permanent location, the fact that it consisted of a lead bucket surrounded by polyethylene pellets made it simple, movable and inexpensive. If need be, more quantities of Cf-252 could be added without altering the basic design and sacrificing the radiation protection guidelines. The measured radiation levels from 300 μg of stored Cf-252 in and around the storage vault were lower than the expected dose rates by a factor of 5. The measured radiation levels around the occupied environs of the facility were below the maximum permissible yearly dose of 500mrem for non-occupational workers. A transport vessel was designed and constructed to carry up to 50 μg of Californium-252 sources. It consisted of a standard 55 gallon steel drum on casters containing cylindrical lead shield surrounded by polyethylene pellets. The measured maximum surface dose rates on the drum and at one meter away were within the radiation protection guidelines and were less than the expected dose rates. A portable shield was designed and constructed to protect the body in afterloading operations and handling of the sources. It consisted of polyethylene pellets in an aluminum box and an attached 10 cm thick plexiglass eye shield. The simple design, with the ease of using polyethylene pellets can be extended to construct bedside shields

  9. Advantages and Disadvantages of Physiological Assessment For Next Generation Control Room Design

    Energy Technology Data Exchange (ETDEWEB)

    Tuan Q. Tran; Ronald L. Boring; Donald D. Dudenhoeffer; Bruce P Hallbert; M. David Keller; Tessa M. Anderson

    2007-08-01

    Abstract - We propose using non-obtrusive physiological assessment (e.g., eye tracking,) to assess human information processing errors (e.g., loss of vigilance) and limitations (e.g., workload) for advanced energy systems early in the design process. This physiological approach for assessing risk will circumvent many limitations of current risk methodologies such as subjective rating (e.g., rater’s biases) and performance modeling (e.g., risk assessment is scripted and is based upon the individual modeler’s judgment). Key uses will be to evaluate (early in the design process) novel control room equipment and configurations as well as newly developed automated systems that will inevitably place a high information load on operators. The physiological risk assessment tool will allow better precision in pinpointing problematic design issues and will provide a “real-time” assessment of risk. Furthermore, this physiological approach would extend the state-of-the-art of human reliability methods from a “static” measure to more “dynamic.” This paper will discuss a broad range of the current popular online performance gauges as well as its advantages and disadvantages for use in next generation control room.

  10. Human factors methods for nuclear control room design. Volume I. Human factors enhancement of existing nuclear control rooms. Final report

    International Nuclear Information System (INIS)

    Seminara, J.L.; Seidenstein, S.; Eckert, S.K.; Smith, D.L.

    1979-11-01

    Human factors engineering is an interdisciplinary specialty concerned with influencing the design of equipment systems, facilities, and operational environments to promote safe, efficient, and reliable operator performance. Human factors approaches were applied in the design of representative nuclear power plant control panels. First, methods for upgrading existing operational control panels were examined. Then, based on detailed human factors analyses of operator information and control requirements, designs of reactor, feedwater, and turbine-generator control panels were developed to improve the operator-control board interface, thereby reducing the potential for operator errors. In addition to examining present-generation concepts, human factors aspects of advanced systems and of hybrid combinations of advanced and conventional designs were investigated. Special attention was given to warning system designs. Also, a survey was conducted among control board designers to (1) develop an overview of design practices in the industry, and (2) establish appropriate measures leading to a more systematic concern for human factors in control board design

  11. Human factors review of nuclear power plant control room design. Summary report

    International Nuclear Information System (INIS)

    Seminara, J.L.; Gonzalez, W.R.; Parsons, S.O.

    1976-11-01

    Human factors engineering is an interdisciplinary specialty concerned with influencing the design of equipment systems, facilities, and operational environments to promote safe, efficient, and reliable operator performance. The human factors aspects of five representative nuclear power plant control rooms were evaluated using such methods as a checklist-guided observation system, structured interviews with operators and trainers, direct observations of operator behavior, task analyses and procedure evaluation, and historical error analyses. The human factors aspects of design practices are illustrated, and many improvements in current practices are suggested. The study recommends that a detailed set of applicable human factors standards be developed to stimulate a uniform and systematic concern for human factors in design considerations

  12. The design of high-Tc superconductors - Room-temperature superconductivity?

    International Nuclear Information System (INIS)

    Tallon, J.L.; Storey, J.G.; Mallett, B.

    2012-01-01

    This year is the centennial of the discovery of superconductivity and the 25th anniversary of the discovery of high-T c superconductors (HTS). Though we still do not fully understand how HTS work, the basic rules of design can be determined from studying their systematics. We know what to do to increase T c and, more importantly, what to do to increase critical current density J c . This in turn lays down a challenge for the chemist. Can the ideal design be synthesized? More importantly, what are the limits? Can one make a room-temperature superconductor? In fact fluctuations place strict constraints on this objective and provide important guidelines for the design of the ideal superconductor.

  13. Design of the control room of the N4-type PWR: main features and feedback operating experience

    International Nuclear Information System (INIS)

    Peyrouton, J.M.; Guillas, J.; Nougaret, Ch.

    2004-01-01

    This article presents the design, specificities and innovating features of the control room of the N4-type PWR. A brief description of control rooms of previous 900 MW and 1300 MW -type PWR allows us to assess the change. The design of the first control room dates back to 1972, at that time 2 considerations were taken into account: first the design has to be similar to that of control rooms for thermal plants because plant operators were satisfied with it and secondly the normal operating situation has to be privileged to the prejudice of accidental situations just as it was in a thermal plant. The turning point was the TMI accident that showed the weight of human factor in accidental situations in terms of pilot team, training, procedures and the ergonomics of the work station. The impact of TMI can be seen in the design of 1300 MW-type PWR. In the beginning of the eighties EDF decided to launch a study for a complete overhaul of the control room concept, the aim was to continue reducing the human factor risk and to provide a better quality of piloting the plant in any situation. The result is the control room of the N4-type PWR. Today the cumulated feedback experience of N4 control rooms represents more than 20 years over a wide range of situations from normal to incidental, a survey shows that the N4 design has fulfilled its aims. (A.C.)

  14. Design, operation, and safety of single-room interventional MRI suites: practical experience from two centers.

    Science.gov (United States)

    White, Mark J; Thornton, John S; Hawkes, David J; Hill, Derek L G; Kitchen, Neil; Mancini, Laura; McEvoy, Andrew W; Razavi, Reza; Wilson, Sally; Yousry, Tarek; Keevil, Stephen F

    2015-01-01

    The design and operation of a facility in which a magnetic resonance imaging (MRI) scanner is incorporated into a room used for surgical or endovascular cardiac interventions presents several challenges. MR safety must be maintained in the presence of a much wider variety of equipment than is found in a diagnostic unit, and of staff unfamiliar with the MRI environment, without compromising the safety and practicality of the interventional procedure. Both the MR-guided cardiac interventional unit at Kings College London and the intraoperative imaging suite at the National Hospital for Neurology and Neurosurgery are single-room interventional facilities incorporating 1.5 T cylindrical-bore MRI scanners. The two units employ similar strategies to maintain MR safety, both in original design and day-to-day operational workflows, and between them over a decade of incident-free practice has been accumulated. This article outlines these strategies, highlighting both similarities and differences between the units, as well as some lessons learned and resulting procedural changes made in both units since installation. © 2014 Wiley Periodicals, Inc.

  15. Design of a wireless, standard-based patient monitoring system for operating rooms

    Energy Technology Data Exchange (ETDEWEB)

    Villalobos Cervantes, A.; Alamo Ramiro, J.M. del

    2016-07-01

    In the last decades, IT has brought several successful innovations into the healthcare field, such as wearable devices or hospital information systems. However, IT adoption in surgical environments has followed a slower pace. In this kind of interventions, the large number of wired monitoring equipment limits the efficiency and movements of surgical staff in the room. Therefore, wireless intercommunication between these devices has become a priority. This paper proposes a solution to these needs, and describes the design of a system that uses wireless technologies to collect data from different monitors and display physicians an integrated vision of the patient’s status. Finally, a functional prototype was developed to validate the proposed design. (Author)

  16. Trends in the design of front-end systems for room temperature solid state detectors

    International Nuclear Information System (INIS)

    Manfredi, Pier F.; Re, Valerio

    2003-01-01

    The paper discusses the present trends in the design of low-noise front-end systems for room temperature semiconductor detectors. The technological advancement provided by submicron CMOS and BiCMOS processes is examined from several points of view. The noise performances are a fundamental issue in most detector applications and suitable attention is devoted to them for the purpose of judging whether or not the present processes supersede the solutions featuring a field-effect transistor as a front-end element. However, other considerations are also important in judging how well a monolithic technology suits the front-end design. Among them, the way a technology lends itself to the realization of additional functions, for instance, the charge reset in a charge-sensitive loop or the time-variant filters featuring the special weighting functions that may be requested in some applications of CdTe or CZT detectors

  17. Structural shielding design of a 6 MV flattening filter free linear accelerator: Indian scenario

    Directory of Open Access Journals (Sweden)

    Bibekananda Mishra

    2017-01-01

    Full Text Available Detailed structural shielding of primary and secondary barriers for a 6 MV medical linear accelerator (LINAC operated with flattening filter (FF and flattening filter free (FFF modes are calculated. The calculations have been carried out by two methods, one using the approach given in National Council on Radiation Protection (NCRP Report No. 151 and the other based on the monitor units (MUs delivered in clinical practice. Radiation survey of the installations was also carried out. NCRP approach suggests that the primary and secondary barrier thicknesses are higher by 24% and 26%. respectively, for a LINAC operated in FF mode to that of a LINAC operated in both FF and FFF modes with an assumption that only 20% of the workload is shared in FFF mode. Primary and secondary barrier thicknesses calculated from MUs delivered on clinical practice method also show the same trend and are higher by 20% and 19%, respectively, for a LINAC operated in FF mode to that of a LINAC operated in both FF and FFF modes. Overall, the barrier thickness for a LINAC operated in FF mode is higher about 20% to that of a LINAC operated in both FF and FFF modes.

  18. Structural Shielding Design of a 6 MV Flattening Filter Free Linear Accelerator: Indian Scenario.

    Science.gov (United States)

    Mishra, Bibekananda; Selvam, T Palani; Sharma, P K Dash

    2017-01-01

    Detailed structural shielding of primary and secondary barriers for a 6 MV medical linear accelerator (LINAC) operated with flattening filter (FF) and flattening filter free (FFF) modes are calculated. The calculations have been carried out by two methods, one using the approach given in National Council on Radiation Protection (NCRP) Report No. 151 and the other based on the monitor units (MUs) delivered in clinical practice. Radiation survey of the installations was also carried out. NCRP approach suggests that the primary and secondary barrier thicknesses are higher by 24% and 26%. respectively, for a LINAC operated in FF mode to that of a LINAC operated in both FF and FFF modes with an assumption that only 20% of the workload is shared in FFF mode. Primary and secondary barrier thicknesses calculated from MUs delivered on clinical practice method also show the same trend and are higher by 20% and 19%, respectively, for a LINAC operated in FF mode to that of a LINAC operated in both FF and FFF modes. Overall, the barrier thickness for a LINAC operated in FF mode is higher about 20% to that of a LINAC operated in both FF and FFF modes.

  19. A HUMAN FACTORS ENGINEERING PROCESS TO SUPPORT HUMAN-SYSTEM INTERFACE DESIGN IN CONTROL ROOM MODERNIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Kovesdi, C.; Joe, J.; Boring, R.

    2017-05-01

    The primary objective of the United States (U.S.) Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program is to sustain operation of the existing commercial nuclear power plants (NPPs) through a multi-pathway approach in conducting research and development (R&D). The Advanced Instrumentation, Information, and Control (II&C) System Technologies pathway conducts targeted R&D to address aging and reliability concerns with legacy instrumentation and control (I&C) and other information systems in existing U.S. NPPs. Control room modernization is an important part following this pathway, and human factors experts at Idaho National Laboratory (INL) have been involved in conducting R&D to support migration of new digital main control room (MCR) technologies from legacy analog and legacy digital I&C. This paper describes a human factors engineering (HFE) process that supports human-system interface (HSI) design in MCR modernization activities, particularly with migration of old digital to new digital I&C. The process described in this work is an expansion from the LWRS Report INL/EXT-16-38576, and is a requirements-driven approach that aligns with NUREG-0711 requirements. The work described builds upon the existing literature by adding more detail around key tasks and decisions to make when transitioning from HSI Design into Verification and Validation (V&V). The overall objective of this process is to inform HSI design and elicit specific, measurable, and achievable human factors criteria for new digital technologies. Upon following this process, utilities should have greater confidence with transitioning from HSI design into V&V.

  20. Preliminary shielding calculation for the system of CyberKnife robotic radiosurgery

    International Nuclear Information System (INIS)

    Toreti, Dalila; Xavier, Clarice; Moura, Fabio

    2011-01-01

    The CyberKnife robotic system uses a manipulator with six grade of freedom for positioning a 6 MV Linac accelerator for treatment of lesions. This paper presents calculations for a standard room, with 200 cm of thickness walls primary, build for a CyberKnife system, and calculations for a room originally designed for a Linac conventional (with gantry), with secondary barriers of 107 cm thickness. After the realization of shielding for both rooms, the results shown that walls of standard room with 200 cm thickness are adequate for the secondary shield, and for a room with a conventional Linac, from all six evaluated points, two would require additional shielding of nine cm and four cm of concrete with 2.4 g/cubic cm. This shows that the CyberKnife system can be installed in a originally designed room for a conventional Linac with neither restrict nor any shielding, since no incidence of beams on the secondary barriers is existent

  1. New architectural design of delivery room reduces morbidity in preterm neonates: a prospective cohort study.

    Science.gov (United States)

    Terrin, Gianluca; Conte, Francesca; Scipione, Antonella; Aleandri, Vincenzo; Di Chiara, Maria; Bacchio, Erica; Messina, Francesco; De Curtis, Mario

    2016-03-23

    A multidisciplinary committee composed of a panel of experts, including a member of the American Academy of Pediatrics and American Institute of Architects, has suggested that the delivery room (DR) and the neonatal intensive care units (NICU) room should be directly interconnected. We aimed to investigate the impact of the architectural design of the DR and the NICU on neonatal outcome. Two cohorts of preterm neonates born at architectural renovation of the DR realized in accordance with specific standards (Cohort 2: "new concept of DR"). In Cohort 1, neonates were initially cared for a conventional resuscitation area, situated in the DR, and then transferred to the NICU, located on a separate floor of the same hospital. In Cohort 2 neonates were assisted at birth directly in the NICU room, which was directly connected to the DR via a pass-through door. The primary outcome of the study was morbidity, defined by the proportion of neonates with at least one complication of prematurity (i.e., late-onset sepsis, patent ductus arteriosus, intraventricular hemorrhage, periventricular leukomalacia, bronchopulmonary dysplasia, retinopathy of prematurity and necrotizing enterocolitis). Secondary outcomes were mortality and duration of hospitalization. Statistical analysis was performed using standard methods by SPSS software. We enrolled 106 neonates (56 in Cohort 1 and 50 in Cohort 2). The main clinical and demographic characteristics of the 2 cohorts were similar. Moderate hypothermia (body temperature ≤ 35.9 °C) was more frequent in Cohort 1 (57%) compared with Cohort 2 (24%, p = 0.001). Morbidity was increased in Cohort 1 (73%) compared with Cohort 2 (44%, p = 0.002). No statistically significant differences in mortality and median duration of hospitalization were observed between the 2 cohorts of the study. If realized according to the proposed architectural standards, renovation of DR and NICU may represent an opportunity to reduce morbidity in preterm neonates.

  2. Shielding container

    International Nuclear Information System (INIS)

    Darling, K.A.M.

    1981-01-01

    A shielding container incorporates a dense shield, for example of depleted uranium, cast around a tubular member of curvilinear configuration for accommodating a radiation source capsule. A lining for the tubular member, in the form of a close-coiled flexible guide, provides easy replaceability to counter wear while the container is in service. Container life is extended, and maintenance costs are reduced. (author)

  3. Radiation shielding calculation using MCNP

    International Nuclear Information System (INIS)

    Masukawa, Fumihiro

    2001-01-01

    To verify the Monte Carlo code MCNP4A as a tool to generate the reference data in the shielding designs and the safety evaluations, various shielding benchmark experiments were analyzed using this code. These experiments were categorized in three types of the shielding subjects; bulk shielding, streaming, and skyshine. For the variance reduction technique, which is indispensable to get meaningful results with the Monte Carlo shielding calculation, we mainly used the weight window, the energy dependent Russian roulette and spitting. As a whole, our analyses performed enough small statistical errors and showed good agreements with these experiments. (author)

  4. Multilivel interfaces for power plant control rooms II: A preliminary design space

    International Nuclear Information System (INIS)

    Vicente, K.J.

    1992-01-01

    Events that are unfamiliar to operators and that have not been anticipated by designers pose the greatest threat to system safely in nuclear power plants. The abstraction hierarchy has been proposed as a representation frame-work that can be adopted to design interfaces that support operators in dealing with these unanticipated events. It consists of a multilevel representation format that represents a plant in terms of both physical and functional constraints. In a companion article, the work that has been done on this topic in academia, industry, and research laboratories was reviewed. On the basis of the results of that review, this article proposes a preliminary design space for multilevel interfaces based on the abstraction hierarchy. This space serves several worthwhile purposes: providing a unified framework within which to compare and contrast previous and future work in this area, providing a coherent research agenda by identifying some of the dimensions that can be meaningfully manipulated and evaluated in future experiments, and finally, serving as an input design by outlining the various decisions that need to be made in developing multilevel interfaces and the different options that are currently available for each of those decisions. Consequently this article should be of interest to researchers, designers, and regulators concerned with nuclear power-plant control rooms

  5. An Analysis of Radiation Penetration through the U-Shaped Cast Concrete Joints of Concrete Shielding in the Multipurpose Gamma Irradiator of BATAN

    Science.gov (United States)

    Ardiyati, Tanti; Rozali, Bang; Kasmudin

    2018-02-01

    An analysis of radiation penetration through the U-shaped joints of cast concrete shielding in BATAN’s multipurpose gamma irradiator has been carried out. The analysis has been performed by calculating the radiation penetration through the U-shaped joints of the concrete shielding using MCNP computer code. The U-shaped joints were a new design in massive concrete construction in Indonesia and, in its actual application, it is joined by a bonding agent. In the MCNP simulation model, eight detectors were located close to the observed irradiation room walls of the concrete shielding. The simulation results indicated that the radiation levels outside the concrete shielding was less than the permissible limit of 2.5 μSv/h so that the workers could safely access electrical room, control room, water treatment facility and outside irradiation room. The radiation penetration decreased as the density of material increased.

  6. Conceptual design for the thermal shield bridges and multilayer insulation in the interconnect region for the SSC

    International Nuclear Information System (INIS)

    Baritchi, D.; Nicol, T.; Boroski, W.

    1991-01-01

    The interconnect region serves as the connection area between magnets. In order to minimize radiant heat transfer in the interconnect area, the authors used shield bridges which span the 80K and 20K shield gap between adjacent magnets. A sliding joint between bridge sections on adjacent magnets accommodates contraction during cool-down. An investigation was done to determine which attachment schemes (riveted or bolted versus welded) are better for heat transfer. Each shield bridge is covered with the same multilayer insulation scheme used throughout the body of the magnet. These shield bridges also contain pressure reliefs for each shield in the event of an internal piping failure. The reliefs are located in the upper half of the shield section in order to prevent liquid spills from impinging directly onto the vacuum vessel wall

  7. Design and implementation of new control room system in Damavand tokamak

    Science.gov (United States)

    Rasouli, H.; Zamanian, H.; Gheidi, M.; Kheiri-Fard, M.; Kouhi, A.

    2017-07-01

    The aim of this paper is design and implementation of an up-to-date control room. The previous control room had a lot of constraints and it was not apposite to the sophisticated diagnostic systems as well as to the modern control and multivariable systems. Although it provided the best output for the considered experiments and implementing offline algorithms among all similar plants, it needed to be developed to provide more capability for complex algorithm mechanisms and this work introduces our efforts in this area. Accordingly, four leading systems were designed and implemented, including real-time control system, online Data Acquisition System (DAS), offline DAS, monitoring and data transmission system. In the control system, three real-time control modules were established based on Digital Signal Processor (DSP). Thanks to them, implementation of the classic and linear and nonlinear intelligent controllers was possible to control the plasma position and its elongation. Also, online DAS was constructed in two modules. Using them, voltages and currents of charge for the capacitor banks and pressure of different parts in vacuum vessel were measured and monitored. Likewise, by real-time processing of the online data, the safety protocol of plant performance was accomplished. In addition, the offline DAS was organized in 13 modules based on Field Programmable Gate Array (FPGA). This system can be used for gathering all diagnostic, control, and performance data in 156 channels. Data transmission system and storing mechanism in the server was provided by data transmitting network and MDSplus standard protocol. Moreover, monitoring software was designed so that it could display the required plots for physical analyses. Taking everything into account, this new platform can improve the quality and quantity of research activities in plasma physics for Damavand tokamak.

  8. Gamma dose rate calculations for conceptual design of a shield system for spent fuel interim dry storage in CNA 1

    International Nuclear Information System (INIS)

    Blanco, A; Gomez S

    2012-01-01

    After completing the rearrangement of the Spent Fuel Elements (SFE) into a compact arrangement in the two storage water pools, Atucha Nuclear Reactor 1 (ANR 1) will leave free position for the wet storage of the SFE discharged until December 2014. Even, in two possible scenarios, such as extending operation from 2015 or the cessation of operation after that date, it will be necessary to empty the interim storage water pools transferring the SFE to a temporary dry storage system. Because the law 25.018 'Management of Radioactive Wastes' implies for the first scenario - operation beyond 2015 - that Nucleoelectrica Argentina S.A. will still be in charge of the dry storage system and for the second - the cessation of operation after 2015 - the National Commission of Atomic Energy (CNEA) will be in charge by the National Management Program of Radioactive Wastes, the interim dry storage system of SNF is an issue of common interest which justifies go forward together. For that purpose and in accordance with the criticality and shielding calculations relevant to the project, in this paper we present the dose rate calculations for shielding conceptual design of a system for dry interim storage of the SFE of ANR 1. The specifications includes that the designed system must be suitable without modification for the SFE of the ANR 2. The results for the calculation of the photon dose rate, in touch and at one meter far, for the Transport Module and the Container of the SFE, are presented, which are required and controlled by the National Regulatory Authority (NRA) and the International Atomic Energy Agency (IAEA). It was used the SAS4 module of SCALE5.1 system and MCNP5. As a design tool for the photon shielding in order to meet current standards for allowable dose rates, a radial and axial parametric analysis were developed based on the thickness of lead of the Transport Module. The results were compared and verified between the two computing systems. Before this

  9. Software Design of SMD LEDs for Homogeneous Distribution of Irradiation in the Model of Dark Room

    Directory of Open Access Journals (Sweden)

    Andrej Liner

    2014-01-01

    Full Text Available This article describes wireless optical data networks using visible spectra of optical radiation with a focus on interior areas with direct line of sight LOS (line-of-sight. This type of network represents progressively evolving area of information technologies. Development of lightning technologies based on white power LED was the impulse for wireless optical data networks based on visible spectra of optical radiation (VLC development. Its basic advantage is the flexibility of users. Users don’t have to stay on one place during the data sharing anymore. Wireless optical data networks represent an alternative solution for metallic and fiber networks [1], [2]. This paper deals with the software simulation of homogeneous distribution of optical irradiation in dark room model, carrying out in LightTools software. First, in previous simulations, the optical source composed from 9 SMD LED’s type LW G6SP-EAFA-JKQL-1 was designed. In various simulations, various numbers and distributions of LED’s were used. These were placed at the ceiling of the dark room. At last, the results of optical irradiation homogeneity are compared.

  10. Design concepts for an integrated control room used as a site-wide operations facility

    International Nuclear Information System (INIS)

    Simon, B.H.; Raghavan, R.; Ujita, H.; Utena, S.; Sakuma, A.; Itoh, T.; Fukura, M.; Ono, I.

    1995-01-01

    The concept of an Integrated Main Control Room (IMCR) evolved from surveys conducted by Tokyo Electric Power Company (TEPCO) with plant managers and workers as their existing GE-type boiling water reactors (BWRs) on the need for improved operating conditions in a new generation of reactors being developed for the next century (around 2010). These reactors will be a further enhancement of the advanced boiling water reactors (ABWRs) now being constructed at the Kashiwazaki-Kariwa site in Japan (no.6 and no.7). TEPCO also saw a need for new thinking on control room design because of projected social conditions in Japan for the 21st century. These projections forecast a smaller number of skilled engineering graduates and those graduates less willing to work in nuclear power because such work is seen as unappealing, conducted in remote geographical locations, and requiring extensive night duty. As one solution to reducing operator burden and decreasing the night shift staff, while making nuclear plant operation more interesting for the operators and reducing labor and construction costs, the IMCR was conceived. (author)

  11. A novel perovskite oxide chemically designed to show multiferroic phase boundary with room-temperature magnetoelectricity

    Science.gov (United States)

    Fernández-Posada, Carmen M.; Castro, Alicia; Kiat, Jean-Michel; Porcher, Florence; Peña, Octavio; Algueró, Miguel; Amorín, Harvey

    2016-09-01

    There is a growing activity in the search of novel single-phase multiferroics that could finally provide distinctive magnetoelectric responses at room temperature, for they would enable a range of potentially disruptive technologies, making use of the ability of controlling polarization with a magnetic field or magnetism with an electric one (for example, voltage-tunable spintronic devices, uncooled magnetic sensors and the long-searched magnetoelectric memory). A very promising novel material concept could be to make use of phase-change phenomena at structural instabilities of a multiferroic state. Indeed, large phase-change magnetoelectric response has been anticipated by a first-principles investigation of the perovskite BiFeO3-BiCoO3 solid solution, specifically at its morphotropic phase boundary between multiferroic polymorphs of rhombohedral and tetragonal symmetries. Here, we report a novel perovskite oxide that belongs to the BiFeO3-BiMnO3-PbTiO3 ternary system, chemically designed to present such multiferroic phase boundary with enhanced ferroelectricity and canted ferromagnetism, which shows distinctive room-temperature magnetoelectric responses.

  12. Control room conceptual design of nuclear power plant with multiple modular high temperature gas-cooled reactors

    International Nuclear Information System (INIS)

    Jia Qianqian; Qu Ronghong; Zhang Liangju

    2014-01-01

    A conceptual design of the control room layout for the nuclear power plant with multiple modular high temperature gas-cooled reactors has been developed. The modular high temperature gas-cooled reactors may need to be grouped to produce as much energy as a utility demands to realize the economic efficiency. There are many differences between the multi-modular plant and the current NPPs in the control room. These differences may include the staffing level, the human-machine interface design, the operation mode, etc. The potential challenges of the human factor engineering (HFE) in the control room of the multi-modular plant are analyzed, including the operation workload of the multi-modular tasks, how to help the crew to keep situation awareness of all modules, and how to support team work, the control of shared system between modules, etc. A concept design of control room for the multi-modular plant is presented based on the design aspect of HTR-PM (High temperature gas-cooled reactor pebble bed module). HFE issues are considered in the conceptual design of control room for the multi-modular plant and some design strategies are presented. As a novel conceptual design, verifications and validations are needed, and focus of further work is sketch out. (author)

  13. Human-machine interface aspects and use of computer-based operator support systems in control room upgrades and new control room designs for nuclear power plants

    International Nuclear Information System (INIS)

    Berg, O.

    1997-01-01

    At the Halden Project efforts are made to explore the possibilities through design, development and validation of Computer-based Operator Support Systems (COSSes) which can assist the operators in different operational situations, ranging from normal operation to disturbance and accident conditions. The programme comprises four main activities: 1) verification and validation of safety critical software systems; 2) man-machine interaction research emphasizing improvements in man-machine interfaces on the basis of human factors studies; 3) computerized operator support systems assisting the operator in fault detection/diagnosis and planning of control actions; and 4) control room development providing a basis for retrofitting of existing control rooms and for the design of advanced concepts. The paper presents the status of this development programme, including descriptions of specific operator support functions implemented in the simulator-based, experimental control room at Halden (HAMMLAB, HAlden Man-Machine LABoratory). These operator aids comprise advanced alarms systems, diagnostic support functions, electronic procedures, critical safety functions surveillance and accident management support systems. The different operator support systems development at the Halden Project are tested and evaluated in HAMMLAB with operators from the Halden Reactor, and occasionally from commercial NPPs, as test subjects. These evaluations provide data on the merits of different operator support systems in an advanced control room setting, as well as on how such systems should be integrated to enhance operator performance. The paper discusses these aspects and the role of computerized operator support systems in plant operation based on the experience from this work at the Halden Project. 15 refs, 5 figs

  14. Human-machine interface aspects and use of computer-based operator support systems in control room upgrades and new control room designs for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Berg, O [Institutt for Energiteknikk, OECD Halden Reactor Project (Netherlands)

    1997-07-01

    At the Halden Project efforts are made to explore the possibilities through design, development and validation of Computer-based Operator Support Systems (COSSes) which can assist the operators in different operational situations, ranging from normal operation to disturbance and accident conditions. The programme comprises four main activities: 1) verification and validation of safety critical software systems; 2) man-machine interaction research emphasizing improvements in man-machine interfaces on the basis of human factors studies; 3) computerized operator support systems assisting the operator in fault detection/diagnosis and planning of control actions; and 4) control room development providing a basis for retrofitting of existing control rooms and for the design of advanced concepts. The paper presents the status of this development programme, including descriptions of specific operator support functions implemented in the simulator-based, experimental control room at Halden (HAMMLAB, HAlden Man-Machine LABoratory). These operator aids comprise advanced alarms systems, diagnostic support functions, electronic procedures, critical safety functions surveillance and accident management support systems. The different operator support systems development at the Halden Project are tested and evaluated in HAMMLAB with operators from the Halden Reactor, and occasionally from commercial NPPs, as test subjects. These evaluations provide data on the merits of different operator support systems in an advanced control room setting, as well as on how such systems should be integrated to enhance operator performance. The paper discusses these aspects and the role of computerized operator support systems in plant operation based on the experience from this work at the Halden Project. 15 refs, 5 figs.

  15. Shielding in experimental areas

    International Nuclear Information System (INIS)

    Stevens, A.; Tarnopolsky, G.; Thorndike, A.; White, S.

    1979-01-01

    The amount of shielding necessary to protect experimental detectors from various sources of background radiation is discussed. As illustrated an experiment has line of sight to sources extending approx. 90 m upstream from the intersection point. Packing a significant fraction of this space with shielding blocks would in general be unacceptable because primary access to the ring tunnel is from the experimental halls. (1) From basic machine design considerations and the inherent necessity to protect superconducting magnets it is expected that experimental areas in general will be cleaner than at any existing accelerator. (2) Even so, it will likely be necessary to have some shielding blocks available to protect experimental apparatus, and it may well be necessary to have a large amount of shielding available in the WAH. (3) Scraping will likely have some influence on all halls, and retractable apparatus may sometimes be necessary. (4) If access to any tunnel is needed to replace a magnet, one has 96 h (4 days) available to move shielding away to permit access without additional downtime. This (the amount of shielding one can shuffle about in 96 h) is a reasonable upper limit to shielding necessary in a hall

  16. Magnetic shielding for superconducting RF cavities

    Science.gov (United States)

    Masuzawa, M.; Terashima, A.; Tsuchiya, K.; Ueki, R.

    2017-03-01

    Magnetic shielding is a key technology for superconducting radio frequency (RF) cavities. There are basically two approaches for shielding: (1) surround the cavity of interest with high permeability material and divert magnetic flux around it (passive shielding); and (2) create a magnetic field using coils that cancels the ambient magnetic field in the area of interest (active shielding). The choice of approach depends on the magnitude of the ambient magnetic field, residual magnetic field tolerance, shape of the magnetic shield, usage, cost, etc. However, passive shielding is more commonly used for superconducting RF cavities. The issue with passive shielding is that as the volume to be shielded increases, the size of the shielding material increases, thereby leading to cost increase. A recent trend is to place a magnetic shield in a cryogenic environment inside a cryostat, very close to the cavities, reducing the size and volume of the magnetic shield. In this case, the shielding effectiveness at cryogenic temperatures becomes important. We measured the permeabilities of various shielding materials at both room temperature and cryogenic temperature (4 K) and studied shielding degradation at that cryogenic temperature.

  17. Study of the radiation scattered and produced by concrete shielding of radiotherapy rooms and its effects on equivalent doses in patients' organs; Estudo da radiacao espalhada e produzida pela blindagem de concreto de salas de radioterapia e seus efeitos sobre doses equivalentes nos orgaos dos pacientes

    Energy Technology Data Exchange (ETDEWEB)

    Braga, K.L.; Rebello, W.F.; Andrade, E.R.; Gavazza, S.; Medeiros, M.P.C.; Mendes, R.M.S.; Gomes, R.G.; Silva, M.G., E-mail: kelmo.lins@gmail.com, E-mail: rebello@ime.eb.br, E-mail: fisica.dna@gmail.com, E-mail: sergiogavazza@yahoo.com, E-mail: eng.cavaliere@gmail.com, E-mail: raphaelmsm@gmail.com, E-mail: ggrprojetos@gmail.com, E-mail: maglosilva15@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Secao de Engenharia Nuclear; Thalhofer, J.L.; Silva, A.X., E-mail: jardellt@yahoo.com.br, E-mail: ademir@con.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Energia Nuclear; Santos, R.F.G., E-mail: raphaelfgsantos@gmail.com [Centro Universitario Anhanguera, Niteroi, RJ (Brazil). Departamento de Engenharia

    2015-07-01

    Within a radiotherapy room, in addition to the primary beam, there is also secondary radiation due to the leakage of the accelerator head and the radiation scattering from room objects, patient and even the room's shielding itself, which is projected to protect external individuals disregarding its effects on the patient. This work aims to study the effect of concrete shielding wall over the patient, taking into account its contribution on equivalent doses. The MCNPX code was used to model the linear accelerator Varian 2100/2300 C/D operating at 18MeV, with MAX phantom representing the patient undergoing radiotherapy treatment for prostate cancer following Brazilian Institute of Cancer four-fields radiation application protocol (0°, 90°, 180° and 270°). Firstly, the treatment was patterned within a standard radiotherapy room, calculating the equivalent doses on patient's organs individually. In a second step, this treatment was modeled withdrawing the walls, floor and ceiling from the radiotherapy room, and then the equivalent doses calculated again. Comparing these results, it was found that the concrete has an average shielding contribution of around 20% in the equivalent dose on the patient's organs. (author)

  18. Verification and validation of human factors issues in control room design and upgrades

    Energy Technology Data Exchange (ETDEWEB)

    Green, M.; Collier, S. [Inst. for Energiteknikk, Halden (Norway). OECD Halden Reactor Project

    1999-12-01

    Systems, facilities and equipment are periodically updated during a power plant's lifetime. This has human factors implications, especially if the central control room is involved. Human factors work may therefore be required. There is an extensive literature on human factors itself, but not so much on how it is verified and validated. Therefore, HRP and the Swedish Nuclear Power Inspectorate commissioned a study. The objective was to review the literature and establish a knowledge base on verification and validation (V and V) of human factors issues. The report first discusses verification and validation as applied to human factors work. It describes a design process and the typical human factors topics involved. It then presents a generic method for V and V of human factors. This is built on a review of standards, guidelines and other references given in an annotated bibliography. The method is illustrated by application to some human factors topics.

  19. Verification and validation of human factors issues in control room design and upgrades

    International Nuclear Information System (INIS)

    Green, M.; Collier, S.

    1999-12-01

    Systems, facilities and equipment are periodically updated during a power plant's lifetime. This has human factors implications, especially if the central control room is involved. Human factors work may therefore be required. There is an extensive literature on human factors itself, but not so much on how it is verified and validated. Therefore, HRP and the Swedish Nuclear Power Inspectorate commissioned a study. The objective was to review the literature and establish a knowledge base on verification and validation (V and V) of human factors issues. The report first discusses verification and validation as applied to human factors work. It describes a design process and the typical human factors topics involved. It then presents a generic method for V and V of human factors. This is built on a review of standards, guidelines and other references given in an annotated bibliography. The method is illustrated by application to some human factors topics

  20. Control room unfiltered in-leakage limit analysis of design-basis LOCA for Lungmen ABWR plant

    International Nuclear Information System (INIS)

    Tsai Chihming; Chang Chinjang; Yuann Yngruey

    2014-01-01

    In USNRC's Generic Letter 2003-01, 'Control Room Habitability,' it requests utilities provide information to demonstrate that the control room at each of their respective facilities complies with the current licensing and design bases, and applicable regulatory requirements, and that suitable design, maintenance and testing control measures are in place for maintaining this compliance. In particular, each utility is required to perform the control room in-leakage test to demonstrate that the unfiltered in-leakage rate is within that assumed in the licensing analyses. It must be ensured that the control room envelope habitability, in terms of radiation dose, is maintained during normal operations as well as design basis accidents. In view of this, a dose analysis has been performed to establish the control room unfiltered in-leakage limit which can be used as an acceptance criterion for the in-leakage test. The analysis in this study is for Lungmen ABWR plant. The plant has twin units, with each unit having its own control room. The TID-4844 source terms and associated methodology are used. The USNRC RADTRAD v3.03 code is employed for the transport calculation of radioactive materials in different paths, including control room in-leakage path. The radiological criterion on protection of the operators specified in 10 CFR 50, Appendix A, General Design Criterion 19 is followed. It's demonstrated that the performance of Lungmen control room with 500 cfm unfiltered in-leakage air could meet the radiological habitability acceptance criteria in case of radiation hazards. (author)