WorldWideScience

Sample records for rollover sleeve technique

  1. Testing of a new prototype surgical stapler that automates the rollover sleeve technique for venous anastomoses

    OpenAIRE

    PATRICIA B CARROLL; WERVISTON DEFARIA; CARLOS GANDIA; MARIANA BERHO; EVANGELOS MISIAKOS; ANDREAS G TZAKIS

    2006-01-01

    The creation of successful vascular anastomoses is of primary importance in many surgical fields. Numerous attempts to automate this process have been made. These techniques have slowly gained acceptance, but their use is still limited. This report details feasibility testing of a new prototype stapler that automates the rollover sleeve technique for venous vascular anastomoses. Male and female mongrel dogs (n=7) (25-32 kg) were used. A segment of the right (n=5) or left (n=2) iliac vein was ...

  2. Testing of a new prototype surgical stapler that automates the rollover sleeve technique for venous anastomoses

    Directory of Open Access Journals (Sweden)

    PATRICIA B CARROLL

    2006-01-01

    Full Text Available The creation of successful vascular anastomoses is of primary importance in many surgical fields. Numerous attempts to automate this process have been made. These techniques have slowly gained acceptance, but their use is still limited. This report details feasibility testing of a new prototype stapler that automates the rollover sleeve technique for venous vascular anastomoses. Male and female mongrel dogs (n=7 (25-32 kg were used. A segment of the right (n=5 or left (n=2 iliac vein was harvested for interposition grafts after the contra lateral side was transected. In each dog, two end-to-end venous anastomoses at the interposition grafts were performed. The standard anastomosis employed continuous mattress sutures. The experimental anastomosis was performed with a new prototype surgical stapler. The stapled anastomosis was proximal and the sutured was distal. In all experiments, it was possible to perform the experimental anastomosis with the stapler. Complications included two small leaks, one due to misfiring of a single pin in one experimental site. These leaks required suture reinforcement. One dog died of hemorrhage due to a slipped suture at the vein harvest site. One vein had thrombus seen at the sutured site although no technical abnormalities at either of the anastomoses could be found. After two weeks, grafts were inspected grossly and histologically. Healing appeared normal. There was a trend for less inflammatory cells infiltrating stapled sites; however, this was not statistically significant. The experiments demonstrate that this device can automate the rollover sleeve technique for venous anastomoses.

  3. Testing of a new prototype surgical stapler that automates the rollover sleeve technique for venous anastomoses.

    Science.gov (United States)

    Carroll, Patricia B; Defaria, Werviston; Gandia, Carlos; Berho, Mariana; Misiakos, Evangelos; Tzakis, Andreas G

    2006-01-01

    The creation of successful vascular anastomoses is of primary importance in many surgical fields. Numerous attempts to automate this process have been made. These techniques have slowly gained acceptance, but their use is still limited. This report details feasibility testing of a new prototype stapler that automates the rollover sleeve technique for venous vascular anastomoses. Male and female mongrel dogs (n=7) (25-32 kg) were used. A segment of the right (n=5) or left (n=2) iliac vein was harvested for interposition grafts after the contra lateral side was transected. In each dog, two end-to-end venous anastomoses at the interposition grafts were performed. The standard anastomosis employed continuous mattress sutures. The experimental anastomosis was performed with a new prototype surgical stapler. The stapled anastomosis was proximal and the sutured was distal. In all experiments, it was possible to perform the experimental anastomosis with the stapler. Complications included two small leaks, one due to misfiring of a single pin in one experimental site. These leaks required suture reinforcement. One dog died of hemorrhage due to a slipped suture at the vein harvest site. One vein had thrombus seen at the sutured site although no technical abnormalities at either of the anastomoses could be found. After two weeks, grafts were inspected grossly and histologically. Healing appeared normal. There was a trend for less inflammatory cells infiltrating stapled sites; however, this was not statistically significant. The experiments demonstrate that this device can automate the rollover sleeve technique for venous anastomoses.

  4. What matters after sleeve gastrectomy: patient characteristics or surgical technique?

    Science.gov (United States)

    Dhar, Vikrom K; Hanseman, Dennis J; Watkins, Brad M; Paquette, Ian M; Shah, Shimul A; Thompson, Jonathan R

    2018-03-01

    The impact of operative technique on outcomes in laparoscopic sleeve gastrectomy has been explored previously; however, the relative importance of patient characteristics remains unknown. Our aim was to characterize national variability in operative technique for laparoscopic sleeve gastrectomy and determine whether patient-specific factors are more critical to predicting outcomes. We queried the database of the Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program for laparoscopic sleeve gastrostomies performed in 2015 (n = 88,845). Logistic regression models were used to determine predictors of postoperative outcomes. In 2015, >460 variations of laparoscopic sleeve gastrectomy were performed based on combinations of bougie size, distance from the pylorus, use of staple line reinforcement, and oversewing of the staple line. Despite such substantial variability, technique variants were not predictive of outcomes, including perioperative morbidity, leak, or bleeding (all P ≥ .05). Instead, preoperative patient characteristics were found to be more predictive of these outcomes after laparoscopic sleeve gastrectomy. Only history of gastroesophageal disease (odds ratio 1.44, 95% confidence interval 1.08-1.91, P < .01) was associated with leak. Considerable variability exists in technique among surgeons nationally, but patient characteristics are more predictive of adverse outcomes after laparoscopic sleeve gastrectomy. Bundled payments and reimbursement policies should account for patient-specific factors in addition to current accreditation and volume thresholds when deciding risk-adjustment strategies. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Sleeve Push Technique: A Novel Method of Space Gaining.

    Science.gov (United States)

    Verma, Sanjeev; Bhupali, Nameksh Raj; Gupta, Deepak Kumar; Singh, Sombir; Singh, Satinder Pal

    2018-01-01

    Space gaining is frequently required in orthodontics. Multiple loops were initially used for space gaining and alignment. The most common used mechanics for space gaining is the use of nickel-titanium open coil springs. The disadvantage of nickel-titanium coil spring is that they cannot be used until the arches are well aligned to receive the stiffer stainless steel wires. Therefore, a new method of gaining space during initial alignment and leveling has been developed and named as sleeve push technique (SPT). The nickel-titanium wires, i.e. 0.012 inches and 0.014 inches along with archwire sleeve (protective tubing) can be used in a modified way to gain space along with alignment. This method helps in gaining space right from day 1 of treatment. The archwire sleeve and nickel-titanium wire in this new SPT act as a mutually synergistic combination and provide the orthodontist with a completely new technique for space opening.

  6. Sleeve push technique: A novel method of space gaining

    Directory of Open Access Journals (Sweden)

    Sanjeev Verma

    2018-01-01

    Full Text Available Space gaining is frequently required in orthodontics. Multiple loops were initially used for space gaining and alignment. The most common used mechanics for space gaining is the use of nickel–titanium open coil springs. The disadvantage of nickel–titanium coil spring is that they cannot be used until the arches are well aligned to receive the stiffer stainless steel wires. Therefore, a new method of gaining space during initial alignment and leveling has been developed and named as sleeve push technique (SPT. The nickel–titanium wires, i.e. 0.012 inches and 0.014 inches along with archwire sleeve (protective tubing can be used in a modified way to gain space along with alignment. This method helps in gaining space right from day 1 of treatment. The archwire sleeve and nickel–titanium wire in this new SPT act as a mutually synergistic combination and provide the orthodontist with a completely new technique for space opening.

  7. 'Stent in a stent'--an alternative technique for removing partially covered stents following sleeve gastrectomy complications.

    Science.gov (United States)

    Vasilikostas, Georgios; Sanmugalingam, Nimalan; Khan, Omar; Reddy, Marcus; Groves, Chris; Wan, Andrew

    2014-03-01

    Endoscopic stenting is a relatively new technique for the treatment of post sleeve gastrectomy complications. Partially covered stents are used in this method to minimise the risk of migration but they are associated with difficulties with removal. Patients requiring emergency stenting following sleeve gastrectomy underwent insertion of a partially covered metallic stent. One month later, if the stent was not easily removable, a fully covered overlapping stent was inserted and the patient was readmitted 2 weeks later for removal of both stents. Four patients required stenting following sleeve gastrectomy leaks, and one patient required stenting for a stricture. In these cases, a 'stent in a stent' technique was used for removal. This technique allows the safe removal of partially covered stents inserted following sleeve gastrectomy complications.

  8. Modified Sleeve Technique in Aortic Valve-Sparing Operation for Marfan Syndrome.

    Science.gov (United States)

    Wu, Yung-Szu; Hsieh, Shih-Rong; Wang, Chung-Chi; Tsai, Chung-Lin

    2018-03-22

    We devised a simple modification of the Florida Sleeve procedure to perform aortic valve-sparing surgery. This technique is simple, quick, effective, and safe. We used this technique in operations performed on two young patients with Marfan syndrome. The initial and short-term results were satisfactory.

  9. Sleeving repair of heat exchanger tubes

    International Nuclear Information System (INIS)

    Street, Michael D.; Schafer, Bruce W.

    2000-01-01

    Defective heat exchanger tubes can be repaired using techniques that do not involve the cost and schedule penalties of component replacement. FTI's years of experience repairing steam generator tubes have been successfully applied to heat exchangers. Framatome Technologies heat exchanger sleeves can bridge defective areas of the heat exchanger tubes, sleeves have been designed to repair typical heat exchanger tube defects caused by excessive tube vibration, stress corrosion cracking, pitting or erosion. By installing a sleeve, the majority of the tube's heat transfer and flow capacity is maintained and the need to replace the heat exchanger can be delayed or eliminated. Both performance and reliability are improved. FTI typically installs heat exchanger tube sleeves using either a roll expansion or hydraulic expansion process. While roll expansion of a sleeve can be accomplished very quickly, hydraulic expansion allows sleeves to be installed deep within a tube where a roll expander cannot reach. Benefits of FTI's heat exchanger tube sleeving techniques include: - Sleeves can be positioned any where along the tube length, and for precise positioning of the sleeve eddy current techniques can be employed. - Varying sleeve lengths can be used. - Both the roll and hydraulic expansion processes are rapid and both produce joints that do not require stress relief. - Because of low leak rates and speed of installations, sleeves can be used to preventatively repair likely-to-fail tubes. - Sleeves can be used for tube stiffening and to limit leakage through tube defects. - Because of installation speed, there is minimal impact on outage schedules and budgets. FTI's recently installed heat exchanger sleeving at the Kori-3 Nuclear Power Station in conjunction with Korea Plant Service and Engineering Co., Ltd. The sleeves were installed in the 3A and 3B component cooling water heat exchangers. A total of 859 tubesheet and 68 freespan sleeves were installed in the 3A heat

  10. Probabilistic finite element modeling of waste rollover

    International Nuclear Information System (INIS)

    Khaleel, M.A.; Cofer, W.F.; Al-fouqaha, A.A.

    1995-09-01

    Stratification of the wastes in many Hanford storage tanks has resulted in sludge layers which are capable of retaining gases formed by chemical and/or radiolytic reactions. As the gas is produced, the mechanisms of gas storage evolve until the resulting buoyancy in the sludge leads to instability, at which point the sludge ''rolls over'' and a significant volume of gas is suddenly released. Because the releases may contain flammable gases, these episodes of release are potentially hazardous. Mitigation techniques are desirable for more controlled releases at more frequent intervals. To aid the mitigation efforts, a methodology for predicting of sludge rollover at specific times is desired. This methodology would then provide a rational basis for the development of a schedule for the mitigation procedures. In addition, a knowledge of the sensitivity of the sludge rollovers to various physical and chemical properties within the tanks would provide direction for efforts to reduce the frequency and severity of these events. In this report, the use of probabilistic finite element analyses for computing the probability of rollover and the sensitivity of rollover probability to various parameters is described

  11. Effects of alignment on the roll-over shapes of prosthetic feet.

    Science.gov (United States)

    Hansen, Andrew

    2008-12-01

    Recent work suggests that a prosthetic ankle-foot component's roll-over shape - the effective rocker it conforms to between initial contact and opposite initial contact (the 'roll-over' interval of walking) - is closely linked to its final alignment in the prosthesis (as determined by a skilled prosthetist using heuristic techniques). If true, this information may help to determine the appropriate alignment for a lower limb prosthesis before it is built, or a priori. Knowledge is needed for future models that will incorporate the roll-over shape including the relative effect of alignment on the roll-over shape's radius of curvature and arc length. The purpose of this study was to evaluate the hypotheses that: (i) Changes in prosthesis alignment alter the position and orientation of a foot's roll-over shape in prosthesis-based coordinates, and (ii) these changes occur without changing the radius of curvature or arc length of the roll-over shape. To examine the hypotheses, this study examined the effects of nine alignment settings on the roll-over shapes of two prosthetic feet. The idea that alignment changes move and rotate roll-over shapes of prosthetic feet in prosthesis coordinates is supported by this work, but the hypothesis that the radius of curvature and arc length do not change for different alignments is not strongly supported by the data. A revised approach is presented that explains some of the changes to the roll-over shape parameters due to changes in rotational alignment.

  12. Basic interrupted versus continuous suturing techniques in bronchial anastomosis following sleeve lobectomy in dogs.

    Science.gov (United States)

    Bayram, Ahmet Sami; Erol, Mehmet Muharrem; Salci, Hakan; Ozyiğit, Ozgür; Görgül, Sacit; Gebitekin, Cengiz

    2007-12-01

    Sleeve resection with or without lung resection is a valid conservative operation for patients with benign or malignant tumors; it enables the preservation of lung parenchyma. The aim of this prospective randomized study was to compare complications, operating time, and bronchial healing between the techniques of interrupted and continuous suturing for bronchial anastomosis in dogs. Twenty adult mongrel dogs each weighing 18-22 kg (average: 20 kg) were divided into two groups according to the anastomosis technique performed: group A, interrupted suturing and group B, continuous suturing. Each group comprised of 10 dogs. Following right thoracotomy, sleeve resection of the right cranial lobe was performed in all dogs. Basic interrupted sutures using 4/0 Vicryl (Ethicon, USA) were used in group A, and continuous sutures were used in group B. The median anastomosis time was 15.2 min (range: 13-21 min) in group A and 9.6 min (range: 8-13 min) in group B. In all dogs, the anastomosis line was resected via right pneumonectomy for histopathological investigation 1 month after sleeve resection. Histopathological examination revealed that the healing of the anastomosis was not affected by the suturing technique applied. One dog from each group died on the fourth postoperative day; Fisher's exact test, p=0.763. Our research revealed that the healing of the anastomosis was not affected by the suturing technique performed.

  13. The weight is over: RN first assisting techniques for laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Wentzell, Joanne; Neff, Marc

    2015-08-01

    Obesity-related laparoscopic sleeve gastrectomy is a common yet technically challenging bariatric procedure that requires specialized surgical knowledge and training for OR personnel. Critical components of care include an effective preoperative assessment, positioning of the patient, and operation and maintenance of laparoscopic equipment and instrumentation. The purpose of this article is to explain the steps of laparoscopic sleeve gastrectomy and illustrate principles and surgical techniques for the RN who is first assisting during the procedure. Also provided is a perioperative nursing care plan for the patient undergoing bariatric surgery, to aid perioperative nurses in understanding the sequence of events and special considerations for this patient population. Copyright © 2015 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  14. Simple, Safe, and Cost-Effective Technique for Resected Stomach Extraction in Laparoscopic Sleeve Gastrectomy.

    Science.gov (United States)

    Derici, Serhan; Atila, Koray; Bora, Seymen; Yener, Serkan

    2016-01-01

    Background. Laparoscopic sleeve gastrectomy (LSG) has become a popular operation during the recent years. This procedure requires resection of 80-90% of the stomach. Extraction of gastric specimen is known to be a challenging and costly stage of the operation. In this paper, we report results of a simple and cost-effective specimen extraction technique which was applied to 137 consecutive LSG patients. Methods. Between October 2013 and October 2015, 137 laparoscopic sleeve gastrectomy surgeries were performed at Dokuz Eylul University General Surgery Department, Upper Gastrointestinal Surgery Unit. All specimens were extracted through a 15 mm trocar site without using any special device. Results. We noticed one superficial incisional surgical site infection and treated this patient with oral antibiotics. No cases of trocar site hernia were observed. Conclusion. Different techniques have been described for specimen extraction. This simple technique allows extraction of specimen safely in a short time and does not require any special device.

  15. Smooth Sliding Mode Control for Vehicle Rollover Prevention Using Active Antiroll Suspension

    Directory of Open Access Journals (Sweden)

    Duanfeng Chu

    2015-01-01

    Full Text Available The rollover accidents induced by severe maneuvers are very dangerous and mostly happen to vehicles with elevated center of gravity, such as heavy-duty trucks and pickup trucks. Unfortunately, it is hard for drivers of those vehicles to predict and prevent the trend of the maneuver-induced (untripped rollover ahead of time. In this study, a lateral load transfer ratio which reflects the load distribution of left and right tires is used to indicate the rollover criticality. An antiroll controller is designed with smooth sliding mode control technique for vehicles, in which an active antiroll suspension is installed. A simplified second order roll dynamic model with additive sector bounded uncertainties is used for control design, followed by robust stability analysis. Combined with the vehicle dynamics simulation package TruckSim, MATLAB/Simulink is used for simulating experiment. The results show that the applied controller can improve the roll stability under some typical steering maneuvers, such as Fishhook and J-turn. This direct antiroll control method could be more effective for untripped rollover prevention when driver deceleration or steering is too late. It could also be extended to handle tripped rollovers.

  16. Heavy truck rollover characterization (phase B).

    Science.gov (United States)

    2009-09-01

    The Heavy Truck Rollover Characterization Study - Phase-B builds on the results of prior phases of research. Phases 1 and 2 (Funded by Federal Highway Administration) involved heavy truck rollover characterization for a tractor and box-trailer; and P...

  17. Tyre influences on untripped vehicle rollover

    NARCIS (Netherlands)

    Jansen, S.T.H.; Lupker, H.A.; Koppenaal, C.J.P.

    2002-01-01

    Vehicle rollover can be initiated by steering actions that occur at vehicle evasive manoeuvres or high speed cornering of commercial vehicles. This untripped vehicle rollover is more difficult to reproduce for passenger cars then for commercial vehicles. For passenger cars it occurs closer to the

  18. Rollover footwear affects lower limb biomechanics during walking.

    Science.gov (United States)

    Forghany, Saeed; Nester, Christopher J; Richards, Barry; Hatton, Anna Lucy; Liu, Anmin

    2014-01-01

    To investigate the effect of rollover footwear on walking speed, metabolic cost of gait, lower limb kinematics, kinetics, EMG muscle activity and plantar pressure. Twenty subjects (mean age-33.1 years, height-1.71 m, body mass-68.9 kg, BMI 23.6, 12 male) walked in: a flat control footwear; a flat control footwear weighted to match the mass of a rollover shoe; a rollover shoe; MBT footwear. Data relating to metabolic energy and temporal aspects of gait were collected during 6 min of continuous walking, all other data in a gait laboratory. The rollover footwear moved the contact point under the shoe anteriorly during early stance, increasing midfoot pressures. This changed internal ankle dorsiflexion moments to plantarflexion moments earlier, reducing ankle plantarflexion and tibialis anterior activity after initial contact, and increasing calf EMG activity. In mid stance the rollover footwear resulted in a more dorsiflexed ankle position but less ankle movement. During propulsion, the rollover footwear reduced peak ankle dorsiflexion, peak internal plantarflexor ankle moments and the range of ankle plantarflexion. Vertical ground reaction loading rates were increased by the rollover footwear. There were no effects on temporal or energy cost of gait and no effect of elevated shoe weight. Investigating all proposed effects of this footwear concurrently has enabled a more valid investigation of how the footwear effects are interrelated. There were concurrent changes in several aspects of lower limb function, with greatest effects at the foot and ankle, but no change in the metabolic cost of walking. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. LMI-Based H¥ Anti-Rollover Control Algorithm of Vehicle Active Suspension

    Directory of Open Access Journals (Sweden)

    LIAO Cong

    2014-10-01

    Full Text Available In order to improve the anti-rollover ability for vehicles, a 4 DOF vehicle rollover dynamics model is established, base on which we have designed an active suspension anti-rollover controller and proposed the H¥ control strategy. Simulations were carried out using Matlab/Simulink, and results show that the proposed control scheme can not only reduce the roll angle and roll angular velocity, but also improve the rollover stability of the vehicle and reduce the probability of vehicle rollover accidents.

  20. Differential Rollover Risk in Vehicle-to-Traffic Barrier Collisions

    Science.gov (United States)

    Gabauer, Douglas J.; Gabler, Hampton C.

    2009-01-01

    In the roadside safety community, there has been debate over the influence of vehicle and barrier type on rollover rates in traffic barrier crashes. This study investigated rollover rates between sport utility vehicles (SUVs), pickup trucks, and cars in vehicle-traffic barrier crashes and has examined the effect of barrier type on rollover risk for concrete barrier and metal barrier impacts. The analysis included 955 barrier impact cases that were selected from 11-years of in-depth crash data available through the National Automotive Sampling System (NASS) / Crashworthiness Data System (CDS). In real world tow-away level longitudinal barrier collisions, the most important predictors of vehicle rollover were found to be vehicle type and whether the vehicle was tracking prior to barrier impact. Based on binary logistic regression, SUVs were found to have 8 times the risk of rollover as cars in barrier impacts. Although pickups were found to have an increased risk of rollover compared to cars, the risk was not as pronounced as that found for SUVs. This finding has direct implications for the full scale crash testing of longitudinal barriers as the testing procedures have been predicated on the assumption that the pickup truck provides a critical or worst case impact scenario. In towaway crashes, our study does not support the notion that concrete barriers have a higher risk of vehicle rollover than metal beam barriers. PMID:20184839

  1. Rollover risk, liquidity and macroprudential regulation

    OpenAIRE

    Ahnert, Toni

    2014-01-01

    I study rollover risk in the wholesale funding market when intermediaries can hold liquidity ex ante and are subject to fire sales ex post. Precautionary liquidity restores multiple equilibria in a global rollover game. An intermediate liquidity level supports both the usual run equilibrium and an efficient equilibrium. I provide a uniqueness refinement to characterize the privately optimal liquidity choice. Because of fire sales, liquidity holdings are strategic substitutes. Intermediaries f...

  2. Gastric Sleeve Surgery

    Science.gov (United States)

    ... Videos for Educators Search English Español Gastric Sleeve Surgery KidsHealth / For Teens / Gastric Sleeve Surgery What's in ... or buying healthy food ) Preparing for Gastric Sleeve Surgery Preparing for this major operation takes months of ...

  3. Vehicle rollover risk and electronic stability control systems.

    Science.gov (United States)

    MacLennan, P A; Marshall, T; Griffin, R; Purcell, M; McGwin, G; Rue, L W

    2008-06-01

    Electronic stability control (ESC) systems were developed to reduce motor vehicle collisions (MVCs) caused by loss of control. Introduced in Europe in 1995 and in the USA in 1996, ESC is designed to improve vehicle lateral stability by electronically detecting and automatically assisting drivers in unfavorable situations. To examine the relationship between vehicle rollover risk and presence of ESC using a large national database of MVCs. A retrospective cohort study for the period 1995 through 2006 was carried out using data obtained from the National Automotive Sampling System General Estimates System. All passenger cars and sport utility vehicles (SUVs)/vans of model year 1996 and later were eligible. Vehicle ESC (unavailable, optional, standard) was determined on the basis of make, model, and model year. Risk ratios (RRs) and 95% CIs were calculated to compare rollover risk by vehicle ESC group. For all crashes, vehicles equipped with standard ESC had decreased risk of rollover (RR = 0.62, 95% CI 0.50 to 0.77) compared with vehicles with ESC unavailable. The association was consistent for single-vehicle MVCs (RR = 0.61, 95% CI 0.46 to 0.82); passenger cars had decreased rollover risk (RR = 0.77, 95% CI 0.52 to 1.12), but SUVs/vans had a more dramatically decreased risk (RR = 0.40, 95% CI 0.26 to 0.61). This study supports previous results showing ESC to be effective in reducing the risk of rollover. ESC is more effective in SUVs/vans for rollovers related to single-vehicle MVCs.

  4. Modelling rollover behaviour of exacavator-based forest machines

    Science.gov (United States)

    M.W. Veal; S.E. Taylor; Robert B. Rummer

    2003-01-01

    This poster presentation provides results from analytical and computer simulation models of rollover behaviour of hydraulic excavators. These results are being used as input to the operator protective structure standards development process. Results from rigid body mechanics and computer simulation methods agree well with field rollover test data. These results show...

  5. Heat flux limiting sleeves

    Science.gov (United States)

    Harris, William G.

    1985-01-01

    A heat limiting tubular sleeve extending over only a portion of a tube having a generally uniform outside diameter, the sleeve being open on both ends, having one end thereof larger in diameter than the other end thereof and having a wall thickness which decreases in the same direction as the diameter of the sleeve decreases so that the heat transfer through the sleeve and tube is less adjacent the large diameter end of the sleeve than adjacent the other end thereof.

  6. Developing an Ontology-Based Rollover Monitoring and Decision Support System for Engineering Vehicles

    Directory of Open Access Journals (Sweden)

    Feixiang Xu

    2018-05-01

    Full Text Available The increasing number of rollover accidents of engineering vehicles has attracted close attention; however, most researchers focus on the analysis and monitoring of rollover stability indexes and seldom the assessment and decision support for the rollover risk of engineering vehicles. In this context, an ontology-based rollover monitoring and decision support system for engineering vehicles is proposed. The ontology model is built for representing monitored rollover stability data with semantic properties and for constructing semantic relevance among the various concepts involved in the rollover domain. On the basis of this, ontology querying and reasoning methods based on the Simple Protocol and RDF Query Language (SPARQL and Semantic Web Rule Language (SWRL rules are utilized to realize the rollover risk assessment and to obtain suggested measures. PC and mobile applications (APPs have also been developed to implement the above methods. In addition, five sets of rollover stability data for an articulated off-road engineering vehicle under different working conditions were analyzed to verify the accuracy and effectiveness of the proposed system.

  7. The efficacy of sleeve technique in primary nasolacrimal duct obstruction with a high lacrimal sac

    Directory of Open Access Journals (Sweden)

    Kyoung-Nam Kim

    2014-01-01

    Full Text Available Purpose: To evaluate the efficacy of a sleeve technique during endoscopic dacryocystorhinostomy (DCR in primary nasolacrimal duct obstruction (NLDO patients with a high lacrimal sac. Materials and Methods: The medical records of 45 patients (49 cases undergoing endoscopic DCR for primary NLDO with a high lacrimal sac were retrospectively reviewed. In 19 patients (21 cases, the thick maxilla covering the common canalicular opening was removed using a drill and a bicanalicular silicone tube was inserted (group 1. In 26 patients (28 cases, instead of removal of the thick maxilla, a sleeve was inserted into the bicanalicular silicone tube (group 2. At 6 months postoperatively, the success rate was evaluated and the size of the intranasal mucosal ostium was measured. Results: The success rates in group 1 and 2 was 90.5% and 96.4%, respectively (P = 0.400. The intranasal mucosal ostium in group 1 and 2 measured 1.7 ± 0.7 mm and 3.1 ± 1.0 mm, respectively, and the difference was significant (P = 0.042. Conclusions: In primary NLDO patients with a high lacrimal sac, DCR inserting a silicone tube and a sleeve together had a satisfactory success rate without using a drill. In comparison with traditional surgical methods, it helped enlarge the size of the intranasal mucosal ostium.

  8. 29 CFR 1926.1000 - Rollover protective structures (ROPS) for material handling equipment.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Rollover protective structures (ROPS) for material handling equipment. 1926.1000 Section 1926.1000 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY... CONSTRUCTION Rollover Protective Structures; Overhead Protection § 1926.1000 Rollover protective structures...

  9. Guide tube sleeve

    International Nuclear Information System (INIS)

    Attix, D.J.

    1983-01-01

    The invention increases the operating capacity of a nuclear reactor by causing a modification in the flow pattern of the coolant which enhances the coolant's effectiveness. The apparatus provides a thin-walled tubular sleeve closely surrounding but not attached to the exterior surface of a guide tube in a fuel assembly. The wall of the sleeve has tabs projecting outwardly into adjacent flow channels. The sleeve is attached to the wall of a cellular void through which passes the guide tube associated with said sleeve. The tabs increase the flow of water in the channel and thus increase the heat transfer

  10. Rollover risk, liquidity, and macro-prudential regulation

    OpenAIRE

    Ahnert, Toni

    2014-01-01

    I study rollover risk in the wholesale funding market when intermediaries can hold liquidity ex-ante and are subject to fire sales ex-post. I demonstrate that precautionary liquidity restores multiple equilibria in a global rollover game. An intermediate liquidity level supports both the usual run equilibrium and an efficient equilibrium. I provide a uniqueness refinement to characterize the privately optimal liquidity choice. Because of fire sales, liquidity holdings are strategic substitute...

  11. Use of color-coded sleeve shutters accelerates oscillograph channel selection

    Science.gov (United States)

    Bouchlas, T.; Bowden, F. W.

    1967-01-01

    Sleeve-type shutters mechanically adjust individual galvanometer light beams onto or away from selected channels on oscillograph papers. In complex test setups, the sleeve-type shutters are color coded to separately identify each oscillograph channel. This technique could be used on any equipment using tubular galvanometer light sources.

  12. Development of an eddy current inspection technique for sleeved engine disk bolt holes

    International Nuclear Information System (INIS)

    Palanisamy, R.; Lakin, K.M.

    1983-01-01

    Recent research programs have concentrated mainly on developing techniques to characterize surface breaking cracks and very little has been done towards characterizing subsurface flaws in conducting materials. Presented in this paper are the results of some initial theoretical work aimed at the development of a reliable eddy current technique to detect and characterize defects in engine disk bolt holes under a 0.05'' stainless steel sleeve. The change in impedance of an absolute eddy current coil with and without ferrite core, and the distribution of eddy currents around a second layer crack with and without a thin insulating film between the two conducting layers have been predicted numerically. The overall system development goals and methods to accomplish them are outlined briefly

  13. PLUSS-A weldless leaktight sleeve for alloy 600/690 steam generator tubes

    International Nuclear Information System (INIS)

    Potz, F.; Bohmann, W.

    1998-01-01

    The ABB PLUSS sleeving represents a new SG tube repair technique qualified and approved to replace in the future most of the plugging as well as welded sleeving. Basically the advantages of an innovative combination of both alloys 600/690 and 800 are taken into consideration. The upper sleeve/SG tube-joint is hydraulically expanded stressing the SG tube only within the elastic range. The lower joint is hard rolled. The installation processes are simple and reproducible, fast, computerized and individually recorded. The operating temperature range of the sleeved SG-tube is effectively reduced so that any further corrosion is impeded. Both, sleeve and SG tube are fully inspectable by ECT. (author)

  14. New TA Index-Based Rollover Prevention System for Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Xiang Liu

    2015-03-01

    Full Text Available In addition to clean transportation and energy savings, electric vehicles can inherently offer better performance in the field of active safety and dynamic stability control, thanks to the superior fast and accurate control characteristics of electric motors. With the novel wheel status parameter TA for electric vehicles proposed by the authors in an earlier publication, a new TA index (TAI-based rollover prevention method is presented in this paper to improve the driving performance of EVs equipped with in-wheel motors. A three-level electric vehicle control structure is used to analyze the effective control steps for rollover prevention with the newly proposed TAI method. The simulation is conducted using an in-house developed electric vehicle dynamic model. The simulation results prove the feasibility of using TAI to detect rollover. The experiment uses an electric vehicle equipped with four in-wheel motors in the authors’ research lab. The vehicle parameter and performance data are imported to CarSim, which is industrial standard vehicle dynamic analysis software to run the rollover test. The experimental results also demonstrate that TAI is an effective method of rollover prevention.

  15. Leak or Fistula After Sleeve Gastrectomy: Treatment with Pigtail Drain by the Rendezvous Technique.

    Science.gov (United States)

    Soufron, Jacques

    2015-10-01

    After a sleeve gastrectomy, a leak or fistula is a serious complication. Laparoscopic drainage, drainage under US or CT scan control, or endoscopic insertion of a stent can be used, but a major re-operation is sometimes unavoidable. Endoscopic drainage with a pigtail catheter could give more success and fewer complications, but the insertion of the drain is not always possible nor does it always provide a perfect drainage. If a laparoscopic second look appears necessary, it is possible to insert a pigtail drain laparoscopically, but under endoscopic control, ensuring a correct positioning of the drain both in the peritoneal cavity and in the gastric tube. This simultaneous "rendezvous" technique could combine in this situation the advantages of purely surgical techniques and of purely endoscopic or image-guided techniques.

  16. SUV rollover in single vehicle crashes and the influence of ESC and SSF.

    Science.gov (United States)

    Kallan, Michael J; Jermakian, Jessica Steps

    2008-10-01

    The modern Sport Utility Vehicle (SUV) fleet continues to go through a transformation in response to the concern that they are at an increased risk of rollover. Our research objective was to look at changes in rollover rates for single vehicle crashes in the modern SUV fleet (corresponding to NCAP rollover testing model years) and the impact of electronic stability control (ESC) and lowered center of gravity. We looked at 2001-2006 NASS-GES data on a probability sample of 3,331 SUVs involved in single vehicle crashes, weighted to represent 324,149 crashes in the study population. Static Stability Factor (SSF) information from NCAP testing and ESC presence (from IIHS) were also incorporated. 20.2% of these SUVs were involved a rollover, which decreased by more than half from model year 2001 (25.3%) through 2006 (11.5%). Nearly 9% had ESC as a standard feature, including 47% in model year 2006. The majority of the late model year decline in rollover rates can be attributed to ESC presence and higher SSF. Rollover was two-thirds less likely (adjusted OR=0.33, 95% CI=0.20-0.55) in SUVs with ESC as a standard feature versus those known not to have ESC. Those SUVs with SSF > or = 1.20 were significantly less likely to rollover (adjusted OR=0.31, 95% CI=0.20-0.48). Additional significant predictors of rollover included SUV size, driver age and alcohol use. Our study builds on the previous work of NHTSA, IIHS, and others with regard to rollover risk by looking at an even wider array of late model year SUVs.

  17. Modeling and testing of a knitted-sleeve fluidic artificial muscle

    Science.gov (United States)

    Ball, Erick J.; Meller, Michael A.; Chipka, Jordan B.; Garcia, Ephrahim

    2016-11-01

    The knitted-sleeve fluidic muscle is similar in design to a traditional McKibben muscle, with a separate bladder and sleeve. However, in place of a braided sleeve, it uses a tubular-knit sleeve made from a thin strand of flexible but inextensible yarn. When the bladder is pressurized, the sleeve expands by letting the loops of fiber slide past each other, changing the dimensions of the rectangular cells in the stitch pattern. Ideally, the internal volume of the sleeve would reach a maximum when its length has contracted by 2/3 from its maximum length, and although this is not reachable in practice, preliminary tests show that free contraction greater than 50% is achievable. The motion relies on using a fiber with a low coefficient of friction in order to reduce hysteresis to an acceptable level. In addition to increased stroke length, potential advantages of this technique include slower force drop-off during the stroke, more useable energy in certain applications, and greater similarity to the force-length relationship of skeletal muscle. Its main limitation is its potentially greater effect from friction compared to other fluidic muscle designs.

  18. A new surgical technique of intra-scleral tube fixation in Ahmed Glaucoma Valve implantation: ‘Scleral Sleeve Method’

    Directory of Open Access Journals (Sweden)

    Charudutt Kalamkar

    2017-10-01

    Full Text Available Purpose: To present a new surgical technique ‘Scleral Sleeve Method’ which would reduce the risk of Ahmed Glaucoma Valve (AGV tube related complications in patients undergoing AGV FP7 (New World Medical Inc., Rancho Cucamonga, CA for refractory glaucoma. Design: Prospective, Non-Randomized, hospital based interventional case series. Subjects: A total of 16 eyes of adult patients (10 males and 6 females with refractory glaucoma. Methods: Instead of using sutures to fix the AGV tube to sclera, we devised a novel method of intra-scleral tube fixation by creating a scleral tunnel fashioned in form of sleeve. Main outcome measure: Post-operative tube related complications. Result: There were no tube related complications such as exposure, extrusion or retraction in any of the cases. Conclusion: Use of scleral sleeve method for tube fixation, along with graft to cover the tube, will provide additional safety measure and reduce the risks of tube related complications. Keywords: Ahmed Glaucoma Valve, Scleral Sleeve Method, Intra-scleral tube fixation

  19. Testing and injury potential analysis of rollovers with narrow object impacts.

    Science.gov (United States)

    Meyer, Steven E; Forrest, Stephen; Herbst, Brian; Hayden, Joshua; Orton, Tia; Sances, Anthony; Kumaresan, Srirangam

    2004-01-01

    Recent statistics highlight the significant risk of serious and fatal injuries to occupants involved in rollover collisions due to excessive roof crush. The government has reported that in 2002. Sports Utility Vehicle rollover related fatalities increased by 14% to more than 2400 annually. 61% of all SUV fatalities included rollovers [1]. Rollover crashes rely primarily upon the roof structures to maintain occupant survival space. Frequently these crashes occur off the travel lanes of the roadway and, therefore, can include impacts with various types of narrow objects such as light poles, utility poles and/or trees. A test device and methodology is presented which facilitates dynamic, repeatable rollover impact evaluation of complete vehicle roof structures with such narrow objects. These tests allow for the incorporation of Anthropomorphic Test Dummies (ATDs) which can be instrumented to measure accelerations, forces and moments to evaluate injury potential. High-speed video permits for detailed analysis of occupant kinematics and evaluation of injury causation. Criteria such as restraint performance, injury potential, survival space and the effect of roof crush associated with various types of design alternatives, countermeasures and impact circumstances can also be evaluated. In addition to presentation of the methodology, two representative vehicle crash tests are also reported. Results indicated that the reinforced roof structure significantly reduced the roof deformation compared to the production roof structure.

  20. Integration of vehicle yaw stabilisation and rollover prevention through nonlinear hierarchical control allocation

    Science.gov (United States)

    Alberding, Matthäus B.; Tjønnås, Johannes; Johansen, Tor A.

    2014-12-01

    This work presents an approach to rollover prevention that takes advantage of the modular structure and optimisation properties of the control allocation paradigm. It eliminates the need for a stabilising roll controller by introducing rollover prevention as a constraint on the control allocation problem. The major advantage of this approach is the control authority margin that remains with a high-level controller even during interventions for rollover prevention. In this work, the high-level control is assigned to a yaw stabilising controller. It could be replaced by any other controller. The constraint for rollover prevention could be replaced by or extended to different control objectives. This work uses differential braking for actuation. The use of additional or different actuators is possible. The developed control algorithm is computationally efficient and suitable for low-cost automotive electronic control units. The predictive design of the rollover prevention constraint does not require any sensor equipment in addition to the yaw controller. The method is validated using an industrial multi-body vehicle simulation environment.

  1. Characterization and Surgical Management of Achilles Tendon Sleeve Avulsions.

    Science.gov (United States)

    Huh, Jeannie; Easley, Mark E; Nunley, James A

    2016-06-01

    disease, while engaged in athletic activity. Suture anchor fixation, combined with addressing concomitant insertional pathology, was a reliable and safe technique for the operative management of Achilles tendon sleeve avulsions. The majority of patients returned to their preinjury levels of work and recreational activity. Level IV, retrospective case series. © The Author(s) 2016.

  2. Patellar Sleeve Fracture With Ossification of the Patellar Tendon.

    Science.gov (United States)

    Damrow, Derek S; Van Valin, Scott E

    2017-03-01

    Patellar sleeve fractures make up greater than 50% of all patellar fractures. They are essentially only seen in the pediatric population because of the thick periosteum and the distal patellar pole apophysis in this group. These fractures can lead to complications if not treated appropriately and in a timely fashion. Complications of missed or untreated patellar sleeve fractures include patella alta, anterior knee pain, and quadriceps atrophy. These can all result in severe limitations in activity. The authors describe a case of a 16-year-old boy who sustained a patellar sleeve fracture 3 years prior to presentation. On presentation, he had patella alta, diminished strength, 5° of extensor lag, and radiographs that revealed bone formation along the patellar tendon. Despite this, he was able to maintain a high level of activity. This case report explores how the patient could have maintained a high level of activity despite having a patellar sleeve fracture. Also, because of the delayed presentation, the patella was ossified and the quadriceps was retracted, which led to a novel approach to reconstructing his distal extensor mechanism. This approach included a V-Y advancement of the quadriceps tendon and patellar tendon reconstruction using the patient's hamstring tendon (semitendinosus). This technique, combined with physical therapy postoperatively, resulted in his return to varsity high school soccer. To the best of the authors' knowledge, this technique has not been reported for this rare condition. [Orthopedics. 2017; 40(2):e357-e359.]. Copyright 2016, SLACK Incorporated.

  3. Countermeasure: Army Ground Risk-Management Publication. Rollover] Rollover] What can you do? Volume 18, Number 12

    National Research Council Canada - National Science Library

    1997-01-01

    .... The number of accidents and the number of fatalities are too high. what can we do about it? Can we make improvements in our efforts to reduce the number of rollover/ turnover accidents, and also improve our chances of surviving such an accident...

  4. Process to repair a steam generator tube by inserting a tubular sleeve and the associated sleeve

    International Nuclear Information System (INIS)

    Gaudin, J.P.

    1986-01-01

    The tubular sleeve is introduced in the tube and is mechanically expanded inside the tube plate, and is diametrally expanded at its upper part within the tube and outside the tube plate. Tightness is ensured by brazing the end part of the sleeve within the tube. The end part of the sleeve is brazed by melting of brazing metal previously applied to the outer surface of the sleeve of its end region. The invention applies more particularly to steam generators of pressurized water nuclear reactors [fr

  5. Root cause analysis of thermal sleeve separation

    Energy Technology Data Exchange (ETDEWEB)

    Jo, J. C.; Jhung, M. J.; Yu, S. O.; Kim, H. J.; Yune, Y. K.; Park, J. Y

    2006-01-15

    Thermal sleeves in the shape of thin wall cylinder seated inside the nozzle part of each Safety Injection (SI) line at Pressurized Water Reactors (PWRs) have such functions as prevention and relief of potential excessive transient thermal stress in the wall of SI line nozzle part which is initially heated up with hot water flowing in the primary coolant piping system when cold water is injected into the system through the SI nozzles during the SI operation mode. Recently, mechanical failures that the sleeves were separated from the SI branch pipe and fell into the connected cold leg main pipe occurred in sequence at some typical PWR plants in Korea. To find out the root cause of thermal sleeve breakaway failures, the flow situation in the junction of primary coolant main pipe and SI branch pipe, and the vibration modal characteristics of the thermal sleeve are investigated in detail by using both Computational Fluid Dynamic (CFD) code and structure analysis finite element code. As the results, the transient response in fluid force exerting on the local part of thermal sleeve wall surface to the primary coolant flow through the pipe junction area during the normal reactor operation mode shows oscillatory characteristics with frequencies ranging from 17 to 18, which coincide with one of the lower mode natural frequencies of thermal sleeve having a pinned support condition on the circumferential prominence on the outer surface of thermal sleeve which is put into the circumferential groove on the inner surface of SI nozzle at the mid-height of the thermal sleeve. In addition, the variation of force on the thermal sleeve surface yields alternating torques in the directions of two rectangular axes which are perpendicular to the longitudinal axis of cylindrical thermal sleeve, which cause rolling, pitching and rotating motions of the thermal sleeve. Consequently, it is seen that this flow situation surrounding the thermal sleeve during the normal reactor operation can

  6. Robust Switched Predictive Braking Control for Rollover Prevention in Wheeled Vehicles

    Directory of Open Access Journals (Sweden)

    Martín Antonio Rodríguez Licea

    2014-01-01

    Full Text Available The aim of this paper is to propose a differential braking rollover mitigation strategy for wheeled vehicles. The strategy makes use of a polytopic (piecewise linear description of the vehicle and includes translational and rotational dynamics, as well as suspension effects. The braking controller is robust and the system states are predicted to estimate the rollover risk up to a given time horizon. In contrast to existing works, the switched predictive nature of the control allows it to be applied only when risk of rollover is foreseen, interfering a minimum with driver’s actions. The stability of the strategy is analyzed and its robustness is illustrated via numerical simulations using CarSim for a variety of vehicles.

  7. Study on the Rollover Characteristic of In-Wheel-Motor-Driven Electric Vehicles Considering Road and Electromagnetic Excitation

    OpenAIRE

    Di Tan; Haitao Wang; Qiang Wang

    2016-01-01

    For in-wheel-motor-driven electric vehicles, the motor is installed in the wheel directly. Tyre runout and uneven load can cause magnet gap deformation in the motor, which will produce electromagnetic forces that further influence the vehicle rollover characteristics. To study the rollover characteristics, a verified 16-degree-of-freedom rollover dynamic model is introduced. Next, the vehicle rollover characteristics both with and without electromagnetic force are analyzed under conditions of...

  8. Framatome technologies successfully performs SG re-sleeving at Kewaunee

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    Framatome Technologies teamed with ABB-CE (Connecticut) to remove previously installed sleeves from the Kewaunee nuclear power stations steam generator tubes and install new sleeves. Recent inspections indicated problems at the upper joint of many of the previous sleeves. The process involved removing most of the hydraulic expansion joint (HEJ) sleeve, expanding the sleeve remnant and the tube section at the upper joint, and installing a TIG-welded sleeve that bridges the problem portion of the tube that the HEJ sleeve covered

  9. Endoscopic sleeve gastroplasty (the Apollo method: a new approach to obesity management

    Directory of Open Access Journals (Sweden)

    Gontrand López-Nava-Breviere

    2016-04-01

    Full Text Available Background: Many obese patients cannot lose weight or reject conventional obesity management. Endoscopic sleeve gastroplasty (the Apollo method is a pioneering coadjuvant, interventionist technique for the integral management of obesity. Objectives: The goals of this study were to report safety and efficacy results obtained at 6 months in patients undergoing endoscopic sleeve gastroplasty. Material and methods: A prospective study was performed in 55 patients (13 males, 42 females who were subjected to the Apollo technique; mean age was 43.5 years (range 25-60 and mean BMI was 37.7 kg/m² (range 30-48. All received multidisciplinary follow-up for weight loss. Weight changes and presence of complications were assessed. Through the endoscope a triangular pattern suture is performed consisting of approximately 3-6 transmural (mucosa to serosa stitches, using a cinch device to bring them nearer and form a plication. Results: A total of 6-8 plications are used to provide a tubular or sleeve-shaped restriction to the gastric cavity. No major complications developed and patients were discharged at 24 hours following the procedure. Endoscopic and radiographic follow-up at 6 months post-procedure showed a well preserved tubular form to the stomach. After 6 months patients had lost 18.9 kg and 55.3% of excess weight. Conclusions: Endoscopic sleeve gastroplasty, together with dietary and psycho-behavioral changes, is a safe, effective technique in the coadjuvant management of obese patients.

  10. The Effects of Curtain Airbag on Occupant Kinematics and Injury Index in Rollover Crash

    Directory of Open Access Journals (Sweden)

    Hongyun Li

    2018-01-01

    Full Text Available Background. Occupant injuries in rollover crashes are associated with vehicle structural performance, as well as the restraint system design. For a better understanding of the occupant kinematics and injury index in certain rollover crash, it is essential to carry out dynamic vehicle rollover simulation with dummy included. Objective. This study focused on effects of curtain airbag (CAB parameters on occupant kinematics and injury indexes in a rollover crash. Besides, optimized parameters of the CAB were proposed for the purpose of decreasing the occupant injuries in such rollover scenario. Method and Material. The vehicle motion from the physical test was introduced as the input for the numerical simulation, and the 50% Hybrid III dummy model from the MADYMO database was imported into a simulation model. The restraint system, including a validated CAB module, was introduced for occupant kinematics simulation and injury evaluation. TTF setting, maximum inflator pressure, and protection area of the CAB were analysed. Results. After introducing the curtain airbag, the maximum head acceleration was reduced from 91.60 g to 49.52 g, and the neck Mx and neck Fz were reduced significantly. Among these CAB parameters, the TTF setting had the largest effect on the head acceleration which could reduce 8.6 g furthermore after optimization. The neck Fz was decreased from 3766.48 N to 2571.77 N after optimization of CAB protection area. Conclusions. Avoiding hard contact is critical for the occupant protection in the rollover crashes. The simulation results indicated that occupant kinematics and certain injury indexes were improved with the help of CAB in such rollover scenario. Appropriate TTF setting and inflator selection could benefit occupant kinematics and injury indexes. Besides, it was advised to optimize the curtain airbag thickness around the head contact area to improve head and neck injury indexes.

  11. Study on the Rollover Characteristic of In-Wheel-Motor-Driven Electric Vehicles Considering Road and Electromagnetic Excitation

    Directory of Open Access Journals (Sweden)

    Di Tan

    2016-01-01

    Full Text Available For in-wheel-motor-driven electric vehicles, the motor is installed in the wheel directly. Tyre runout and uneven load can cause magnet gap deformation in the motor, which will produce electromagnetic forces that further influence the vehicle rollover characteristics. To study the rollover characteristics, a verified 16-degree-of-freedom rollover dynamic model is introduced. Next, the vehicle rollover characteristics both with and without electromagnetic force are analyzed under conditions of the Fixed Timing Fishhook steering and grade B road excitation. The results show that the electromagnetic force has a certain effect on the load transfer and can reduce the antirollover performance of the vehicle. Therefore, the effect of the electromagnetic force on the rollover characteristic should be considered in the vehicle design. To this end, extensive analysis was conducted on the effect of the road level, vehicle speed, and the road adhesion coefficient on the vehicle rollover stability. The results indicate that vehicle rollover stability worsens when the above-mentioned factors increase, the most influential factor being the road adhesion coefficient followed by vehicle speed and road level. This paper can offer certain theory basis for the design of the in-wheel-motor-driven electric vehicles.

  12. A generic analytical foot rollover model for predicting translational ankle kinematics in gait simulation studies.

    Science.gov (United States)

    Ren, Lei; Howard, David; Ren, Luquan; Nester, Chris; Tian, Limei

    2010-01-19

    The objective of this paper is to develop an analytical framework to representing the ankle-foot kinematics by modelling the foot as a rollover rocker, which cannot only be used as a generic tool for general gait simulation but also allows for case-specific modelling if required. Previously, the rollover models used in gait simulation have often been based on specific functions that have usually been of a simple form. In contrast, the analytical model described here is in a general form that the effective foot rollover shape can be represented by any polar function rho=rho(phi). Furthermore, a normalized generic foot rollover model has been established based on a normative foot rollover shape dataset of 12 normal healthy subjects. To evaluate model accuracy, the predicted ankle motions and the centre of pressure (CoP) were compared with measurement data for both subject-specific and general cases. The results demonstrated that the ankle joint motions in both vertical and horizontal directions (relative RMSE approximately 10%) and CoP (relative RMSE approximately 15% for most of the subjects) are accurately predicted over most of the stance phase (from 10% to 90% of stance). However, we found that the foot cannot be very accurately represented by a rollover model just after heel strike (HS) and just before toe off (TO), probably due to shear deformation of foot plantar tissues (ankle motion can occur without any foot rotation). The proposed foot rollover model can be used in both inverse and forward dynamics gait simulation studies and may also find applications in rehabilitation engineering. Copyright 2009 Elsevier Ltd. All rights reserved.

  13. Performance of Grouted Splice Sleeve Connector under Tensile Load

    Directory of Open Access Journals (Sweden)

    A. Alias

    2016-05-01

    Full Text Available The grouted splice sleeve connector system takes advantage of the bond-slip resistance of the grout and the mechanical gripping of reinforcement bars to provide resistance to tensile force. In this system, grout acts as a load-transferring medium and bonding material between the bars and sleeve. This study adopted the end-to-end rebars connection method to investigate the effect of development length and sleeve diameter on the bonding performance of the sleeve connector. The end-to-end method refers to the condition where reinforcement bars are inserted into the sleeve from both ends and meet at the centre before grout is filled. Eight specimens of grouted splice sleeve connector were tested under tensile load to determine their performance. The sleeve connector was designed using 5 mm thick circular hollow section (CHS steel pipe and consisted of one external and two internal sleeves. The tensile test results show that connectors with a smaller external and internal sleeve diameter appear to provide better bonding performance. Three types of failure were observed in this research, which are bar fracture (outside the sleeve, bar pullout, and internal sleeve pullout. With reference to these failure types, the development length of 200 mm is the optimum value due to its bar fracture type, which indicates that the tensile capacity of the connector is higher than the reinforcement bar. It is found that the performance of the grouted splice sleeve connector is influenced by the development length of the reinforcement bar and the diameter of the sleeve.

  14. Improvements in nuclear fuel assembly sleeves

    International Nuclear Information System (INIS)

    Eaton, C.W.; Seeley, T.A.; Ince, G.; Speakman, W.T.

    1986-01-01

    The graphite sleeve of a nuclear fuel assembly or reflector element for a stringer mounts a number of grids via mounting assemblies installed in grooves formed in the interior wall surface of the sleeve. The bore of the sleeve is of reduced cross-section between two successive grooves such that the internal diameter of the sleeve is substantially the same as the inner diameter of the radially innermost extremity of the mounting assemblies whereby the coolant pressure loss at each transition between the reduced diameter bore section and the mounting assemblies is reduced. Each mounting assembly may be of radially contractable split ring construction to permit its placement in the groove and may carry burnable poison material. (author)

  15. Improvements in nuclear fuel assembly sleeves

    Energy Technology Data Exchange (ETDEWEB)

    Eaton, C.W.; Seeley, T.A.; Ince, G.; Speakman, W.T.

    1986-02-26

    The graphite sleeve of a nuclear fuel assembly or reflector element for a stringer mounts a number of grids via mounting assemblies installed in grooves formed in the interior wall surface of the sleeve. The bore of the sleeve is of reduced cross-section between two successive grooves such that the internal diameter of the sleeve is substantially the same as the inner diameter of the radially innermost extremity of the mounting assemblies whereby the coolant pressure loss at each transition between the reduced diameter bore section and the mounting assemblies is reduced. Each mounting assembly may be of radially contractable split ring construction to permit its placement in the groove and may carry burnable poison material.

  16. 49 CFR 575.105 - Vehicle rollover.

    Science.gov (United States)

    2010-10-01

    ...) The message area must be white with black text. (C) The pictograms must be black with a white..., either: (A) The rollover warning label must be affixed to the right (as viewed from the driver's seat) of... thereafter select a different option for that vehicle. If a manufacturer chooses to certify compliance with...

  17. Seismic retrofit of spliced sleeve connections for precast bridge piers.

    Science.gov (United States)

    2017-03-01

    Grouted Splice Sleeve (GSS) connectors are being considered for connecting bridge columns, footings, and pier caps in Accelerated Bridge Construction (ABC). A repair technique for precast reinforced concrete bridge column-to-footing and column-to-pie...

  18. 26 CFR 31.3405(c)-1 - Withholding on eligible rollover distributions; questions and answers.

    Science.gov (United States)

    2010-04-01

    ... plan administrator withhold tax from an eligible rollover distribution for which a direct rollover..., DEPARTMENT OF THE TREASURY (CONTINUED) EMPLOYMENT TAXES AND COLLECTION OF INCOME TAX AT SOURCE EMPLOYMENT TAXES AND COLLECTION OF INCOME TAX AT SOURCE Collection of Income Tax at Source § 31.3405(c)-1...

  19. Grid sleeve bulge tool

    International Nuclear Information System (INIS)

    Phillips, W.D.; Vaill, R.E.

    1980-01-01

    An improved grid sleeve bulge tool is designed for securing control rod guide tubes to sleeves brazed in a fuel assembly grid. The tool includes a cylinder having an outer diameter less than the internal diameter of the control rod guide tubes. The walls of the cylinder are cut in an axial direction along its length to provide several flexible tines or ligaments. These tines are similar to a fork except they are spaced in a circumferential direction. The end of each alternate tine is equipped with a semispherical projection which extends radially outwardly from the tine surface. A ram or plunger of generally cylindrical configuration and about the same length as the cylinder is designed to fit in and move axially of the cylinder and thereby force the tined projections outwardly when the ram is pulled into the cylinder. The ram surface includes axially extending grooves and plane surfaces which are complimentary to the inner surfaces formed on the tines on the cylinder. As the cylinder is inserted into a control rod guide tube, and the projections on the cylinder placed in a position just below or above a grid strap, the ram is pulled into the cylinder, thus moving the tines and the projections thereon outwardly into contact with the sleeve, to plastically deform both the sleeve and the control rod guide tube, and thereby form four bulges which extend outwardly from the sleeve surface and beyond the outer periphery of the grid peripheral strap. This process is then repeated at the points above the grid to also provide for outwardly projecting surfaces, the result being that the grid is accurately positioned on and mechanically secured to the control rod guide tubes which extend the length of a fuel assembly

  20. A comprehensive review of rollover accidents involving vehicles equipped with Electronic Stability Control (ESC) systems.

    Science.gov (United States)

    Padmanaban, Jeya; Shields, Leland E; Scheibe, Robert R; Eyges, Vitaly E

    2008-10-01

    This study investigated 478 police accident reports from 9 states to examine and characterize rollover crashes involving ESC-equipped vehicles. The focus was on the sequence of critical events leading to loss of control and rollover, and the interactions between the accident, driver, and environment. Results show that, while ESC is effective in reducing loss of control leading to certain rollover crashes, its effectiveness is diminished in others, particularly when the vehicle departs the roadway or when environmental factors such as slick road conditions or driver factors such as speeding, distraction, fatigue, impairment, or overcorrection are present.

  1. Roof strength and injury risk in rollover crashes of passenger cars.

    Science.gov (United States)

    Brumbelow, Matthew L; Teoh, Eric R

    2009-12-01

    A 2009 study by the Insurance Institute for Highway Safety found that midsize SUVs with stronger roofs, as measured in quasi-static tests, had lower risk of ejection and lower risk of injury for nonejected drivers. The objective of the present study was to determine whether a similar association exists for other vehicle groups. Twelve small passenger cars were evaluated according to Federal Motor Vehicle Safety Standard 216 test conditions. Crash databases in 14 states provided more than 20,000 single-vehicle rollover crashes involving these vehicles. Logistic regression analyses were used to evaluate the effect of roof strength on the rate of driver injury while assessing and controlling for the effects of driver age, vehicle stability, state, and other factors where necessary. Small cars with stronger roofs had lower overall rates of serious injury, lower rates of ejection, and lower rates of injury for nonejected drivers. Although the effect on ejection was somewhat smaller for cars than for SUVs, the overall pattern of injury results was consistent. For roof strength-to-weight ratio measured within 5 in. (SWR(5)), a one-unit increase (e.g., from 2.0 to 3.0) was associated with a 22 percent reduction in risk of incapacitating or fatal driver injury in single-vehicle rollovers. This compares with a 24 percent reduction estimated for a similar change in roof strength among midsize SUVs. The association between vehicle roof strength and occupant injury risk in rollover crashes appears robust across different vehicle groups and across roof SWR(5) values, varying from just more than 1.5 to just less than 4.0. If roofs were to increase in strength by one SWR(5), a 20-25 percent reduction in risk of serious injury in rollovers would be expected. Still, even if all vehicle roofs were as strong as the strongest roof measured, many rollover injuries still would occur, indicating the need for additional research and countermeasures.

  2. Parametric study for design of thermal sleeves

    International Nuclear Information System (INIS)

    Mukherjee, A.B.; Mehra, V.K.

    1985-01-01

    Thermal sleeves are used inside nozzle in many reactor components. Basic aim in design of thermal sleeve is to arrive at a set of dimensions for gap and annulus length, which will give rise to minimum thermal gradient in the base metal of the associated nozzle. Study includes the minimisation of the thermal gradient in the crotch zone by suitable choice of gap and annulus length. Three different geometries of nozzle radii 50.00 mm., 100 mm. and 200.0 mm. are studied for single and two concentric thermal sleeves model. The paper also presents effect of parameters like velocity of flow, temperature of fluid, materials etc. on the design of thermal sleeves. (orig.)

  3. [Outcomes, controversies and gastric volume after laparoscopic sleeve gastrectomy in the treatment of obesity].

    Science.gov (United States)

    García-Díaz, Juan José; Ferrer-Márquez, Manuel; Moreno-Serrano, Almudena; Barreto-Rios, Rogelio; Alarcón-Rodríguez, Raquel; Ferrer-Ayza, Manuel

    2016-01-01

    Laparoscopic sleeve gastrectomy is a surgical procedure for the treatment of morbid obesity. However, there are still controversies regarding its efficiency in terms of weight reduction and incidence of complications. In this prospective study, the experience is presented of a referral centre for the treatment of morbid obesity with laparoscopic sleeve gastrectomy. A prospective study on 73 patients subjected to laparoscopic sleeve gastrectomy from February 2009 to September 2013. Patients were followed-up for a period of 12 months, evaluating the development of complications, reduction of gastric volume, and the weight loss associated with the surgery, as well as their impact on the improvement of comorbidities present at beginning of the study. There was a statistically a significantly reduction between the preoperative body mass index (BMI) and the BMI at 12 months after laparoscopic sleeve gastrectomy (p < 0.001), despite there being an increase in the gastric volume during follow-up, measured at one month and 12 months after surgery (p < 0.001). Five patients (6.85%) had complications, with none of them serious and with no deaths in the whole series. Laparoscopic sleeve gastrectomy is a safe and effective technique for the treatment of morbid obesity. Its use is associated with a significant reduction in the presence of comorbidities associated with obesity. Multicentre studies with a longer period of monitoring are required to confirm the efficacy and safety of this surgical technique. Copyright © 2015 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  4. The TaSST: Tactile Sleeve for Social Touch

    NARCIS (Netherlands)

    Huisman, G.; Darriba Frederiks, A.; van Dijk, B.; Heylen, D.; Kröse, B.

    2013-01-01

    In this paper we outline the design process of the TaSST (Tactile Sleeve for Social Touch), a touch-sensitive vibrotactile arm sleeve. The TaSST was designed to enable two people to communicate different types of touch over a distance. The touch-sensitive surface of the sleeve consists of a grid of

  5. The TaSST: Tactile sleeve for social touch

    NARCIS (Netherlands)

    Huisman, Gijs; Darriba Frederiks, Aduén; van Dijk, Elisabeth M.A.G.; Heylen, Dirk K.J.; Krose, Ben

    In this paper we outline the design process of the TaSST (Tactile Sleeve for Social Touch), a touch-sensitive vibrotactile arm sleeve. The TaSST was designed to enable two people to communicate different types of touch over a distance. The touch-sensitive surface of the sleeve consists of a grid of

  6. The TaSST - Tactile Sleeve for Social Touch

    NARCIS (Netherlands)

    Huisman, Gijs; Darriba Frederiks, Aduén; Van Dijk, Betsy; Heylen, Dirk

    2013-01-01

    In this paper we outline the design process of TaSST (Tactile Sleeve for Social Touch), a touch-sensitive vibrotactile arm sleeve. The TaSST was designed to enable two people to communicate different types of touches over a distance. The touch-sensitive surface of the sleeve consists of a grid of

  7. Analgesic Effect of Intraperitoneal Bupivacaine Hydrochloride After Laparoscopic Sleeve Gastrectomy: a Randomized Clinical Trial.

    Science.gov (United States)

    Alamdari, Nasser Malekpour; Bakhtiyari, Mahmood; Gholizadeh, Barmak; Shariati, Catrine

    2018-03-01

    The indications for sleeve gastrectomy as a primary procedure for the surgical treatment of morbid obesity have increased worldwide. Pain is the most common complaint for patients on the first day after laparoscopic sleeve gastrectomy. There are various methods for decreasing pain after laparoscopic sleeve gastrectomy such as the use of intraperitoneal bupivacaine hydrochloride. This clinical trial was an attempt to discover the effects of intraperitoneal bupivacaine hydrochloride on alleviating postoperative pain after laparoscopic sleeve gastrectomy. In general, 120 patients meeting the inclusion criteria were enrolled. Patients were randomly allocated into two interventions and control groups using a balanced block randomization technique. One group received intraperitoneal bupivacaine hydrochloride (30 cm 3 ), and the other group served as the control one and did not receive bupivacaine hydrochloride. Diclofenac suppository and paracetamol injection were administered to both groups for postoperative pain management. The mean subjective postoperative pain score was significantly decreased in patients who received intraperitoneal bupivacaine hydrochloride within the first 24 h after the surgery; thus, the instillation of bupivacaine hydrochloride was beneficial in managing postoperative pain. The intraoperative peritoneal irrigation of bupivacaine hydrochloride (30 cm 3 , 0.25%) in sleeve gastrectomy patients was safe and effective in reducing postoperative pain, nausea, and vomiting (IRCT2016120329181N4).

  8. Intra-thoracic Sleeve Migration (ITSM): an Underreported Phenomenon After Laparoscopic Sleeve Gastrectomy.

    Science.gov (United States)

    Saber, Alan A; Shoar, Saeed; Khoursheed, Mousa

    2017-08-01

    Despite its technical simplicity, laparoscopic sleeve gastrectomy (LSG) complications are increasingly reported. Intra-thoracic sleeve migration (ITSM ) is a rare complication after LSG which has been inconsistently addressed in the literature. The purpose of this study was to emphasize ITSM occurrence after LSG and evaluate the perioperative factors associated with its development. Between January and July 2016, LSG patients diagnosed with ITSM at two bariatric surgery departments were identified. Perioperative factors were assessed for all the patients and compared between two groups, LSG alone and LSG with concomitant hiatal hernia (HH) repair (HHR). A total of 19 patients (6 males and 13 females) were included. Central obesity was present in 18 patients (94.7%). Nine patients (47.4%) had concomitant hiatal hernia repair during their original LSG. Post-LSG GERD (94.7%) (38.9% de novo and 61.1% recurrent) and post-LSG constipation (57.9%) were commonly associated with ITSM. Severe refractory GERD was the most common presentation for ITSM (94.7%), followed by epigastric pain (47.4%), persistent nausea/vomiting (36.8%), and dysphagia (21.1%). Time interval between primary LSG and ITSM diagnosis ranged from 1 day to 3 years. Patients with LSG and concomitant HHR presented with higher post-LSG BMI compared to the LSG patients (37 ± 6.4 kg/m 2 vs. 30.1 ± 6.3 kg/m 2 , p = 0.03). All the patients underwent successful reduction of ITSM and subsequent HHR. Central obesity, chronic constipation, post-LSG GERD, and concomitant HHR are commonly seen in post-laparoscopic sleeve gastrectomy intra-thoracic sleeve migration.

  9. Modified sleeve anastomosis for reconstruction of the hepatic artery in rat liver transplantation.

    Science.gov (United States)

    Li, Jun; Dahmen, Uta; Dirsch, Olaf; Shen, Kai; Gu, Yanli; Broelsch, Christoph Erich

    2002-01-01

    End-to-end sleeve anastomosis between a donor common hepatic artery and a recipient proper hepatic artery was proven to be the most physiological and simple method for hepatic rearterialization in rat liver transplantation. Current technical variants of the sleeve technique, however, are hampered by the high rate of bleeding from the anastomotic site. This report deals with a technical modification which inhibits postoperative bleeding efficiently. The procedure consisted of a guiding suture, as previously described in other technical variants, and a modified fixing suture. Instead of using a single stitch to fix the feeding vessel with the receiving vessel, a running suture between the edge of the donor common hepatic artery and the adventitia of the recipient proper hepatic artery was performed to avoid a possible backflow. The patency rate of 91% was as high as reported by others using a sleeve technique, which was also reflected in the histomorphological picture, being indistinguishable from normal liver histology. This technical modification simplified the procedure of reconstructing the hepatic artery and could contribute to a wider use of the arterialized liver transplantation model in rats. Copyright 2002 Wiley-Liss, Inc.

  10. Bronchus anastomosis after sleeve resection for lung cancer: does the suture technique have an impact on postoperative complication rate?

    Science.gov (United States)

    Palade, Emanuel; Holdt, Holger; Passlick, Bernward

    2015-06-01

    Bronchoplastic resections emerged as an alternative to pneumonectomy for patients with impaired pulmonary function and have gained popularity due to a marked decrease in morbidity and at least similar oncological outcome. Actual guidelines recommend sleeve resections whenever technically feasible, even in cases with adequate pulmonary reserve for pneumonectomy, in order to maximally preserve functional lung parenchyma. Various suture techniques were described; the existing evidence, however, is insufficient to recommend one of them as standard. The aim of this study was to compare two suture techniques for bronchus repair after sleeve resection. Two groups of patients from two separate institutions were retrospectively analysed. In Group A (n = 20), the anastomosis was performed with a running suture at the membranous part and an interrupted suture for the rest of the circumference. In Group B (n = 40), a telescoping continuous suture was used. Intra- and postoperative findings directly related to the anastomosis were compared. The parameters were assessed as absolute numbers and percentages; the statistical significance was determined using Pearson's χ(2) test for categorical variables and Student's t-test for continuous data (P resection type (predominance of the right upper lobe for Group B), the groups were comparable regarding patient characteristics. The intraoperative anastomotic assessment revealed: patency 100% in both groups, initial air tightness (100 vs 82.5%; P = 0.047) and buttressing 85 vs 5%. No suture revision was necessary in both groups. The analysis of anastomosis-related morbidity revealed no significant difference: atelectasis (1 in Group A and 2 in Group B; P = 1), reversible anastomotic changes (0 vs 2; P = 0.309), early stenosis (0 vs 0), bronchopleural fistula (1 vs 0; P = 0.154), bronchovascular fistula (0 vs 0), late stenosis (1 vs 0; P = 0.119) and reoperations (15 vs 5%; P = 0.186). The operative mortality rate was similar (2 vs 3; P

  11. All carbon coaxial supercapacitors based on hollow carbon nanotube sleeve structure

    International Nuclear Information System (INIS)

    Zang, Xiaobei; Xu, Ruiqiao; Zhang, Yangyang; Zhang, Li; Wei, Jinquan; Wang, Kunlin; Zhu, Hongwei; Li, Xinming

    2015-01-01

    All carbon coaxial supercapacitors based on hollow carbon nanotube (CNT) sleeve structure are assembled and tested. The key advantage of the structure is that the inner core electrode is variable from CNT sleeve sponges, to CNT fibers, reduced graphene oxide fibers, and graphene woven fabrics. By changing core electrodes from sleeve sponges to CNT fibers, the electrochemical performance has been significantly enhanced. The capacitance based on sleeve sponge + CNT fiber double the capacitances of double-sleeve sponge supercapacitors thanks to reduction of the series and internal resistances. Besides, the coaxial sleeve structure possesses many other features, including high rate capacitance, long cycle life, and good flexibility. (paper)

  12. Field Tests of a Tractor Rollover Detection and Emergency Notification System.

    Science.gov (United States)

    Liu, B; Koc, A B

    2015-04-01

    The objective of this research was to assess the feasibility of a rollover detection and emergency notification system for farm tractors using field tests. The emergency notification system was developed based on a tractor stability model and implemented on a mobile electronic device with the iOS operating system. A complementary filter was implemented to combine the data from the accelerometer and gyroscope sensors to improve their accuracies in calculating the roll and pitch angles and the roll and pitch rates. The system estimates a stability index value during tractor operation, displays feedback messages when the stability index is lower than a preset threshold value, and transmits emergency notification messages when an overturn happens. Ten tractor rollover tests were conducted on a field track. The developed system successfully monitored the stability of the tractor during all of the tests. The iOS application was able to detect rollover accidents and transmit emergency notifications in the form of a phone call and email when an accident was detected. The system can be a useful tool for training and education in safe tractor operation. The system also has potential for stability monitoring and emergency notification of other on-road and off-road motorized vehicles.

  13. The effects of sleeve gastectomy on gastro-esophageal reflux and gastro-esophageal motility.

    Science.gov (United States)

    Hayat, Jamal O; Wan, Andrew

    2014-05-01

    Sleeve gastrectomy is an increasingly performed bariatric procedure associated with low morbidity and good short to medium term effects on weight loss and comorbid conditions. Studies assessing the prevalence of post-operative gastro-esophageal reflux disease (GERD), show sleeve gastrectomy may provoke de novo GERD symptoms or worsening of pre-existing GERD. Pathophysiological mechanisms of GERD after sleeve gastrectomy include a hypotensive lower esophageal sphincter, increased gastro-esophageal pressure gradient and intra-thoracic migration of the remnant stomach. A reduction in the compliance of the gastric remnant may provoke an increase in transient lower esophageal sphincter relaxations. Time-resolved MRI suggests relative gastric stasis in the proximal remnant and increased emptying from the antrum. A lack of standardisation of technique, along with heterogeneity of studies assessing GERD may explain the wide variability in reported results. Simultaneous and careful repair of an associated hiatus hernia may result in a reduction in the prevalence of post-operative GERD.

  14. Extending service life of steam generators by sleeving tubes

    International Nuclear Information System (INIS)

    Gutzwiller, J.E.

    1982-01-01

    Steam generator tubes that are failing due to IGA in the tubesheet crevice can be kept in service by using the basic sealable sleeve design developed by BandW. Variations of the present sleeve design could significantly reduce the number of tubes that must be plugged each year. Sleeving had the potential of keeping 28 percent more tubes in service during 1979. Lowering the overall rate at which tubes are removed from service by plugging will reduce the probability of having to derate the plant or replace the steam generator. Considering tomorrow's replacement power costs, sleeving to keep tubes in service is a practical and sound investment

  15. Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Im [Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Kyung Hee University Hospital at Gangdong, Kyung Hee University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Park, Chang Min; Goo, Jin Mo [Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of); Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Lee, Sang Min [Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of)

    2015-07-15

    To investigate the effect of rapid needle-out patient-rollover approach on the incidence of pneumothorax and drainage catheter placement due to pneumothorax in C-arm Cone-beam CT (CBCT)-guided percutaneous transthoracic needle biopsy (PTNB) of lung lesions. From May 2011 to December 2012, 1227 PTNBs were performed in 1191 patients with a 17-gauge coaxial needle. 617 biopsies were performed without (conventional-group) and 610 with rapid-rollover approach (rapid-rollover-group). Overall pneumothorax rates and incidences of pneumothorax requiring drainage catheter placement were compared between two groups. There were no significant differences in overall pneumothorax rates between conventional and rapid-rollover groups (19.8 % vs. 23.1 %, p = 0.164). However, pneumothorax rate requiring drainage catheter placement was significantly lower in rapid-rollover-group (1.6 %) than conventional-group (4.2 %) (p = 0.010). Multivariate analysis revealed male, age > 60, bulla crossed, fissure crossed, pleura to target distance > 1.3 cm, emphysema along needle tract, and pleural punctures ≥ 2 were significant risk factors of pneumothorax (p < 0.05). Regarding pneumothorax requiring drainage catheter placement, fissure crossed, bulla crossed, and emphysema along needle tract were significant risk factors (p < 0.05), whereas rapid-rollover approach was an independent protective factor (p = 0.002). The rapid needle-out patient-rollover approach significantly reduced the rate of pneumothorax requiring drainage catheter placement after CBCT-guided PTNB. (orig.)

  16. SCC testing of steam generator tubes repaired by welded sleeves

    International Nuclear Information System (INIS)

    Pierson, E.; Stubbe, J.

    1993-01-01

    One way to repair steam generator tubing is to introduce a sleeve inside the tube so that it spans the corroded area and to seal it at both ends. This technique has been studied at Laborelec with a particular attention paid to the occurrence of new SCC cracks at the upper joint. Tube segments coming from the same lot of mill annealed alloy 600 were sent to six manufacturers to be sleeved by their own procedure (including TIG, laser or kinetic welding, followed or not by a stress relief heat treatment), and then tested at Laborelecin 10% NaOH at 350 degrees C. The tests were performed with and without differential pressure i.e. in capsules (Δ = 9 and 19 MPa) and in autoclave (Δp = 0). Nearly all the not stress relieved mock-ups developed through cracks in several hundred hours in auto-clave. The cracks were circumferential and situated near the weld. At 9 and 19 MPa, the time to failure decreased and longitudinal cracks appeared near the weld and at the transition zone of expanded areas. Cracks were never observed in the alloy 690 sleeve, except in the weld bead. Reference capsules (roll expaned tubes) made of the same lot of alloy 600 were tested in the same environment

  17. Determining asymmetry of roll-over shapes in prosthetic walking

    NARCIS (Netherlands)

    Curtze, C.; Otten, Bert; Hof, A.L.; Postema, K.

    2011-01-01

    How does the inherent asymmetry of the locomotor system in people with lower-limb amputation affect the ankle-foot roll-over shape of prosthetic walking? In a single-case design, we evaluated the walking patterns of six people with lower-limb amputation (3 transtibial and 3 transfemoral) and three

  18. Hybrid video-assisted thoracic surgery with segmental-main bronchial sleeve resection for non-small cell lung cancer.

    Science.gov (United States)

    Li, Shuben; Chai, Huiping; Huang, Jun; Zeng, Guangqiao; Shao, Wenlong; He, Jianxing

    2014-04-01

    The purpose of the current study is to present the clinical and surgical results in patients who underwent hybrid video-assisted thoracic surgery with segmental-main bronchial sleeve resection. Thirty-one patients, 27 men and 4 women, underwent segmental-main bronchial sleeve anastomoses for non-small cell lung cancer between May 2004 and May 2011. Twenty-six (83.9%) patients had squamous cell carcinoma, and 5 patients had adenocarcinoma. Six patients were at stage IIB, 24 patients at stage IIIA, and 1 patient at stage IIIB. Secondary sleeve anastomosis was performed in 18 patients, and Y-shaped multiple sleeve anastomosis was performed in 8 patients. Single segmental bronchiole anastomosis was performed in 5 cases. The average time for chest tube removal was 5.6 days. The average length of hospital stay was 11.8 days. No anastomosis fistula developed in any of the patients. The 1-, 2-, and 3-year survival rates were 83.9%, 71.0%, and 41.9%, respectively. Hybrid video-assisted thoracic surgery with segmental-main bronchial sleeve resection is a complex technique that requires training and experience, but it is an effective and safe operation for selected patients.

  19. Early and medium term results of the sleeve valve-sparing procedure for aortic root ectasia.

    Science.gov (United States)

    Gamba, Amando; Tasca, Giordano; Giannico, Floriana; Lobiati, Elisabetta; Skouse, Douglas; Galanti, Andrea; Martino, Antonello Stefano; Triggiani, Michele

    2015-04-01

    The aim of this retrospective study was to evaluate our experience of using a simplified aortic valve sleeve procedure to treat aortic root ectasia and aneurysms with or without aortic regurgitation. In experienced hands, 2 aortic valve-sparing procedures, ie, Yacoub and David, have yielded excellent long-term results in the treatment of aortic root aneurysms, with or without aortic regurgitation. However, these techniques are demanding and not widely used. Recently, a new and simplified valve-sparing technique, named "sleeve procedure," has been proposed, and has yielded encouraging early results. Ninety consecutive patients with aortic root aneurysms underwent sleeve procedures from October 2006 to October 2012. Follow-up data (clinical 100% complete and echocardiographic 93% complete) were acquired from our outpatient clinic or from the referring cardiologist. The mean age of the patients was 61.5 ± 12.5 years, 79% were male, 16 (18%) had a bicuspid valve, 3 had Marfan syndrome, and 2 had aortic dissection. Over a mean clinical follow-up of 34 ± 19 months, 2 patients died from noncardiac causes and 1 was reoperated on for the recurrence of aortic regurgitation. On follow-up echocardiography after a mean of 18 ± 9 months, aortic regurgitation was absent/negligible, mild or moderate in 62%, 37%, and 1% of patients, respectively, and the diameters of the annulus, Valsalva sinuses, and sinotubular junction were 27.3 + 2.2, 37.0 + 3.4, and 30.6 + 3.1 mm, respectively. Our encouraging early and medium term results suggest that the sleeve procedure is a safe and effective aortic valve-sparing technique for the treatment of aortic root ectasia and aneurysm. However, longer follow-up is needed in order to draw definitive conclusions. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Laparoscopic Sleeve Gastrectomy Improves Olfaction Sensitivity in Morbidly Obese Patients.

    Science.gov (United States)

    Hancı, Deniz; Altun, Huseyin; Altun, Hasan; Batman, Burcin; Karip, Aziz Bora; Serin, Kursat Rahmi

    2016-03-01

    Olfactory abilities of the patients are known to be altered by eating and metabolic disorders, including obesity. There are only a number of studies investigating the effect of obesity on olfaction, and there is limited data on the changes in olfactory abilities of morbidly obese patients after surgical treatment. Here we investigated the changes in olfactory abilities of 54 morbidly obese patients (M/F, 22/32; age range 19-57 years; body mass index (BMI) range 30.5-63.0 kg/m(2)) after laparoscopic sleeve gastrectomy. A laparoscopic sleeve gastrectomy was performed by the same surgeon using five-port technique. Olfactory abilities were tested preoperatively and 1, 3, and 6 months after the surgery using a standardized Sniffin' Sticks Extended Test kit. Analyses of variance indicated statistically significant improvement in T, D, and I scores of morbidly obese patients within time factors (preoperative vs. 1, 3, and 6 months; 1 vs. 3 and 6 months; and 3 vs. 6 months; p < 0.001 for all). There was a statistically significant improvement in overall TDI scores with an increase from 25 to 41 during the 6 months follow-up period (p < 0.001 for all). Here, for the first time in literature, we were able to show the significant improvement in olfactory abilities of morbidly obese patients after laparoscopic sleeve gastrectomy.

  1. 77 FR 20442 - Sunwest Rollover Member LLC; Notice of Application

    Science.gov (United States)

    2012-04-04

    ... limited liability company formed for the purpose of holding equity interests (``Rollover Equity Interests'') in BRE/SW Portfolio LLC (``Blackstone LLC''),\\1\\ a Delaware limited liability company, to resolve the... common interests and class A preferred units, each as defined in the limited liability company agreement...

  2. ENDOSCOPIC SLEEVE GASTROPLASTY FOR OBESITY TREATMENT: TWO YEARS OF EXPERIENCE.

    Science.gov (United States)

    Lopez-Nava, Gontrand; Galvão, M P; Bautista-Castaño, I; Fernandez-Corbelle, J P; Trell, M; Lopez, N

    2017-01-01

    Bariatric endoscopic techniques are minimally invasive and induce gastric volume reduction to treat obesity. Aim : To evaluate endoscopic sleeve gastroplasty (Apollo method) using a suturing method directed at the greater curvature, as well as the perioperative care, two year safety and weight loss. Prospective single-center study over 154 patients (108 females) using the endoscopic sleeve gastroplasty procedure under general anesthesia with overnight inpatient observation. Of the154 initial patients, 143 were available for 1-month of follow-up, 133 for 6-month, 64 for 12-month and 28 completed the 24 month assessment. Follow-up was carried out by a multidisciplinary team (nutritionist and psychologist). Outcomes evaluated were: change in BMI; change in body weight (TBWL); % of loss of initial body weight (%TBWL); % of excess body weight loss (%EWL) (segregated in > or 25% %EWL. There were no mayor adverse events intraprocedure or during the 24 months of follow-up . Endoscopic sleeve gastroplasty with regular monitoring by a multidisciplinary team can be considered an effective, safe and well tolerated procedure for obesity treatment, at least for two years of follow-up. As técnicas de endoscopia bariátrica são minimamente invasivas e induzem à redução do volume gástrico para tratar a obesidade. Avaliar a gastroplastia sleeve endoscópica (método Apollo) usando um método de sutura direcionado para a grande curvatura, bem como os cuidados perioperatórios, segurança em dois anos e perda de peso. Estudo prospectivo em um único centro com 154 pacientes (108 mulheres) usando o procedimento endoscópico de gastroplastia sleeve sob anestesia geral com observação do paciente internado durante a noite. Dos 154 pacientes iniciais, 143 estiveram disponíveis para acompanhamento de um mês, 133 durante seis meses, 64 durante 12 meses e 28 completaram a avaliação de 24 meses. O acompanhamento foi realizado por equipe multidisciplinar (nutricionista e psic

  3. Improved design and durability of aluminum die casting horizontal shot sleeves

    Science.gov (United States)

    Birceanu, Sebastian

    The design and performance of shot sleeves is critical in meeting the engineering requirements of aluminum die cast parts. Improvement in shot sleeve materials have a major impact on dimensional stability, reproducibility and quality of the product. This investigation was undertaken in order to improve the life of aluminum die casting horizontal shot sleeves. Preliminary pin tests were run to evaluate the soldering, wash-out and thermal fatigue behavior of commercially available materials and coatings. An experimental rig was designed and constructed for shot sleeve configuration evaluation. Fabrication and testing of experimental shot sleeves was based upon preliminary results and manufacturing costs. Three shot sleeve designs and materials were compared to a reference nitrided H13 sleeve. Nitrided H13 is the preferred material for aluminum die casting shot sleeves because of wear resistance, strength and relative good soldering and wash-out resistance. The study was directed towards damage evaluation on the area under the pouring hole. This area is the most susceptible to damage because of high temperatures and impingement of molten aluminum. The results of this study showed that tungsten and molybdenum had the least amount of soldering and wash-out damage, and the best thermal fatigue resistance. Low solubility in molten aluminum and stability of intermetallic layers are main factors that determine the soldering and wash-out behavior. Thermal conductivity and thermal expansion coefficient directly influence thermal fatigue behavior. TiAlN nanolayered coating was chosen as the material with the best damage resistance among several commercial PVD coatings, because of relatively large thickness and simple deposition conditions. The results show that molybdenum thermal sprayed coating provided the best protection against damage under the pouring hole. Improved bonding is however required for life extension of the coating. TiAlN PVD coating applied on H13 nitrided

  4. Root cause analysis of SI line-seated thermal sleeve separation failures

    International Nuclear Information System (INIS)

    Jo, Jong Chull; Jhung, Myung Jo; Kim, Hho Jung

    2004-01-01

    At conventional pressurized water reactors, a thermal sleeve (named simply 'sleeve' hereafter) is seated inside the nozzle part of each Safety Injection (SI) branch pipe to prevent and relieve potential excessive transient thermal stress in the nozzle wall when a cold water is injected during the safety injection mode Recently, mechanical failures that the sleeves are separated from the SI branch pipe and fall into the connected cold leg main pipe were occurred in sequence at Yonggwang units 5 and 6 and Ulchin unit 5. There were many activities and efforts to figure out the causes of those failures with experts' reasoning, but the proposed causes were derived from superficial views rather than physically concrete grounds or analysis results. The prerequisites to find out the root causes of failure mechanism will be to identify the flow situation in the pipe junction area connecting the cold leg with the SI pipe and to know the vibration characteristics of sleeves. This paper investigates the flow field in the pipe junction thru a numerical simulation and vibration characteristics of thermal sleeves thru a modal analysis, from which the root causes of sleeve separation mechanism are analyzed

  5. Sleeve Muscle Actuator and Its Application in Transtibial Prostheses

    Science.gov (United States)

    Zheng, Hao; Shen, Xiangrong

    2014-01-01

    This paper describes the concept of a new sleeve muscle actuator, and a transtibial prosthesis design powered by this novel actuator. Inspired by the functioning mechanism of the traditional pneumatic muscle actuator, the sleeve muscle actuator incorporates a cylindrical insert to the center of the pneumatic muscle, which eliminates the central portion of the internal volume. As a result of this change, the sleeve muscle provides multiple advantages over the traditional pneumatic muscle, including the increased force capacity over the entire range of motion, reduced energy consumption, and faster dynamic response. Furthermore, utilizing the load-bearing tube as the insert, the sleeve muscle enables an innovative “actuation-load bearing” structure, which has a potential of generating a highly compact actuation system suitable for prosthetic use. Utilizing this new actuator, the preliminary design of a transtibial prosthesis is presented, which is able to provide sufficient torque output and range of motion for a 75 Kg amputee user in level walking. PMID:24187262

  6. Sleeve gastrectomy and gastro-oesophageal reflux disease: a complex relationship.

    Science.gov (United States)

    Mahawar, Kamal K; Jennings, Neil; Balupuri, Shlok; Small, Peter K

    2013-07-01

    Sleeve gastrectomy is rapidly becoming popular as a standalone bariatric operation. At the same time, there are valid concerns regarding its long-term durability and postoperative gastro-oesophageal reflux disease. Though gastric bypass remains the gold standard bariatric operation, it is not suitable for all patients. Sleeve gastrectomy is sometimes the only viable option. Patients with inflammatory bowel disease, liver cirrhosis, significant intra-abdominal adhesions involving small bowel and those reluctant to undergo gastric bypass could fall in this category. It is widely recognised that some patients report worsening of their gastro-oesophageal reflux disease after sleeve gastrectomy. Still, others develop de novo reflux. This review examines if it is possible to identify these patients prior to surgery and thus prevent postoperative gastro-oesophageal reflux disease after sleeve gastrectomy.

  7. Laparoscopic sleeve gastrectomy for morbid obesity with natural orifice specimen extraction (NOSE).

    Science.gov (United States)

    Gunkova, P; Gunka, I; Zonca, P; Dostalik, J; Ihnat, P

    2015-01-01

    An experience with laparoscopic sleeve gastrectomy using the natural orifice specimen extraction (NOSE) technique. Bariatric surgery is nowadays the only long term effective obesity treatment method. Twenty one consecutive patients underwent laparoscopic sleeve gastrectomy with the use of natural orifice specimen extraction (NOSE) in the Surgical Clinic of Faculty Hospital Ostrava between May 2012 and August 2012. Inclusion criteria were the body mass index (BMI) higher than 35 kg/m2 or higher than 32 kg/m2 accompanied with relevant comorbidities. Among 21 patients in this series, there were three men (14.3%) and 18 women (85.7%). Their mean age was 40.9±10.2 years. Their mean preoperative BMI was 40.4±4.6 kg/m2. No patient had previous bariatric surgery, one patient had laparoscopic fundoplication. All operations were completed laparoscopically with no conversions to an open procedure. In two cases, laparoscopic cholecystectomy was performed and the gallbladder was extracted along with the gastric specimen by transgastric approach. Laparoscopic sleeve gastrectomy is a safe and effective bariatric procedure with low morbidity and mortality. Based on our initial experiences it could be an indication for NOSE with transgastric approach. Obese patients would benefit from this approach due to the elimination of wound complications (Tab. 2, Fig. 3, Ref. 22).

  8. Sleeve type repair of degraded nuclear steam generator tubes

    International Nuclear Information System (INIS)

    Ayres, P.S.; Stark, L.E.; Feldstein, J.G.; Fu, T.

    1986-01-01

    A sealable sleeve is described for insertion into the repair of a degraded tube which consists of: a hollow core inner member of the same material as the degraded tube; a thinner outer member of substantially pure nickel and resistant to corrosive attack, the outer member being metallurgically bonded with the inner member; an expanded portion of the sleeve at one end for positioning in the tube within a tube sheet; a multiplicity of grooves formed in and adjacent to the other end of the sleeve which extends into the free-standing portion of the tube beyond the tube sheet, and a noble metal braze material contained in the grooves

  9. 30 CFR 77.403-1 - Mobile equipment; rollover protective structures (ROPS).

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Mobile equipment; rollover protective structures (ROPS). 77.403-1 Section 77.403-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE...

  10. Self Touch to Touch Others: Designing the Tactile Sleeve for Social Touch

    NARCIS (Netherlands)

    Huisman, G.; Darriba Frederiks, A.; van Dijk, B.; Kröse, B.; Heylen, D.

    2013-01-01

    In this paper we present the concept and initial design stages of the TaSST (Tactile Sleeve for Social Touch). The TaSST consists of a soft pressure-sensitive input layer, and an output layer containing vibration motors. A touch to ones own sleeve is felt as a vibration on the sleeve of another

  11. Self touch to touch others : designing the tactile sleeve for social touch

    NARCIS (Netherlands)

    Huisman, Gijs; Darriba Frederiks, Aduén; Heylen, Dirk; Van Dijk, Betsy; Kröse, Ben

    2013-01-01

    In this paper we present the concept and initial design stages of the TaSST (Tactile Sleeve for Social Touch). The TaSST consists of a soft pressure-sensitive input layer, and an output layer containing vibration motors. A touch to ones own sleeve is felt as a vibration on the sleeve of another

  12. Dysphagia after vertical sleeve gastrectomy: Evaluation of risk factors and assessment of endoscopic intervention.

    Science.gov (United States)

    Nath, Anand; Yewale, Sayali; Tran, Tung; Brebbia, John S; Shope, Timothy R; Koch, Timothy R

    2016-12-21

    To evaluate the risks of medical conditions, evaluate gastric sleeve narrowing, and assess hydrostatic balloon dilatation to treat dysphagia after vertical sleeve gastrectomy (VSG). VSG is being performed more frequently worldwide as a treatment for medically-complicated obesity, and dysphagia is common post-operatively. We hypothesize that post-operative dysphagia is related to underlying medical conditions or narrowing of the gastric sleeve. This is a retrospective, single institution study of consecutive patients who underwent sleeve gastrectomy from 2013 to 2015. Patients with previous bariatric procedures were excluded. Narrowing of a gastric sleeve includes: inability to pass a 9.6 mm gastroscope due to stenosis or sharp angulation or spiral hindering its passage. Of 400 consecutive patients, 352 are included; the prevalence of dysphagia is 22.7%; 33 patients (9.3%) have narrowing of the sleeve with 25 (7.1%) having sharp angulation or a spiral while 8 (2.3%) have a stenosis. All 33 patients underwent balloon dilatation of the gastric sleeve and dysphagia resolved in 13 patients (39%); 10 patients (30%) noted resolution of dysphagia after two additional dilatations. In a multivariate model, medical conditions associated with post-operative dysphagia include diabetes mellitus, symptoms of esophageal reflux, a low whole blood thiamine level, hypothyroidism, use of non-steroidal anti-inflammatory drugs, and use of opioids. Narrowing of the gastric sleeve and gastric sleeve stenosis are common after VSG. Endoscopic balloon dilatations of the gastric sleeve resolves dysphagia in 69% of patients.

  13. Weight Loss after Sleeve Gastrectomy in Super Superobesity

    Directory of Open Access Journals (Sweden)

    J.-M. Catheline

    2012-01-01

    Full Text Available Objective. This prospective study evaluated laparoscopic sleeve gastrectomy for its safety and efficiency in excess weight loss (%EWL in super superobese patients (BMI >60 Kg/m2. Results. Thirty patients (33 women and 7 men were included, with mean age of 35 years (range 18 to 59. Mean preoperative BMI was 66 Kg/m2 (range 60 to 85. The study included one patient with complete situs inversus and 4 (14% with previous restrictive gastric banding. The mean operative time was 120 minutes (range 80 to 220 min and the mean hospital stay was 7.5 days (4 to 28 days. There was no postoperative mortality or need for a laparotomy conversion. Two subphrenic hematomas, one gastric fistula, and one pulmonary embolism, were the major complications. After 18 months 17 (77% had sufficient weight loss and six had insufficient results, leading to either re-sleeve gastrectomy (3, or gastric bypass (2. Three years after the initial laparoscopic sleeve gastrectomy, the mean EWL was 51% (range 21 to 82. Conclusion. The laparoscopic sleeve gastrectomy is a safe and efficient operating procedure for treating super superobesity. In the case of insufficient weight loss, a second-stage operation like resleeve gastrectomy or gastric bypass can be proposed.

  14. Dysphagia after vertical sleeve gastrectomy: Evaluation of risk factors and assessment of endoscopic intervention

    Science.gov (United States)

    Nath, Anand; Yewale, Sayali; Tran, Tung; Brebbia, John S; Shope, Timothy R; Koch, Timothy R

    2016-01-01

    AIM To evaluate the risks of medical conditions, evaluate gastric sleeve narrowing, and assess hydrostatic balloon dilatation to treat dysphagia after vertical sleeve gastrectomy (VSG). METHODS VSG is being performed more frequently worldwide as a treatment for medically-complicated obesity, and dysphagia is common post-operatively. We hypothesize that post-operative dysphagia is related to underlying medical conditions or narrowing of the gastric sleeve. This is a retrospective, single institution study of consecutive patients who underwent sleeve gastrectomy from 2013 to 2015. Patients with previous bariatric procedures were excluded. Narrowing of a gastric sleeve includes: inability to pass a 9.6 mm gastroscope due to stenosis or sharp angulation or spiral hindering its passage. RESULTS Of 400 consecutive patients, 352 are included; the prevalence of dysphagia is 22.7%; 33 patients (9.3%) have narrowing of the sleeve with 25 (7.1%) having sharp angulation or a spiral while 8 (2.3%) have a stenosis. All 33 patients underwent balloon dilatation of the gastric sleeve and dysphagia resolved in 13 patients (39%); 10 patients (30%) noted resolution of dysphagia after two additional dilatations. In a multivariate model, medical conditions associated with post-operative dysphagia include diabetes mellitus, symptoms of esophageal reflux, a low whole blood thiamine level, hypothyroidism, use of non-steroidal anti-inflammatory drugs, and use of opioids. CONCLUSION Narrowing of the gastric sleeve and gastric sleeve stenosis are common after VSG. Endoscopic balloon dilatations of the gastric sleeve resolves dysphagia in 69% of patients. PMID:28058017

  15. Ex-vivo release of Pipeline Embolization Device polytetrafluoroethylene (PTFE) sleeves for improved distal landing zone accuracy in-vivo: A technical note.

    Science.gov (United States)

    Griessenauer, Christoph J; Gupta, Raghav; Moore, Justin; Thomas, Ajith J; Ogilvy, Christopher S

    2016-12-01

    Distal landing zone accuracy is critical in some intracranial aneurysms treated with the Pipeline Embolization Device (PED), and delayed opening of the distal end of the device can complicate the procedure. Here, we report a technical nuance that facilitates accurate placement of the distal end of the PED by ex-vivo, pre-implantation release of the PED Flex polytetrafluoroethylene (PTFE) sleeves. The PED Flex is partially pushed out of the introducer sheath ex-vivo, pre-implantation until the distal PED opens entirely and the PTFE sleeves are located distal to the device. Without inverting the PTFE sleeves, the PED is carefully pulled back into the introducer sheath placing the PTFE sleeves inside the device. The PED is loaded into the microcatheter and advanced toward the site of implantation. When the PED is initially deployed and pushed out of the microcatheter, it opens immediately and provides an anchor for the remainder of the deployment process. We present a video (supplementary material) that illustrates the technique along with an illustrative case. Ex-vivo, pre-implantation release of the PTFE sleeves is an option in aneurysm treatment where distal landing accuracy is critical. Even without the protection of the PTFE sleeves, our clinical observation shows that the PED can be advanced safely through the microcatheter in selected cases. © The Author(s) 2016.

  16. Early Laparoscopic Sleeve Gastrectomy Outcomes in Terms of Weight Loss

    International Nuclear Information System (INIS)

    Siddiq, G.; Aziz, W.; Pervez, M. B.; Haider, M. I.; Hussain, S. V.; Khan, N.

    2016-01-01

    Objective: To investigate the outcomes of laparoscopic sleeve gastrectomy (LSG) in terms of weight loss. Study Design: Descriptive cohort study. Place and Duration of Study: Department of Surgery, Shifa International Hospital, Islamabad, from January 2009 to January 2015. Methodology: A total of 100 consecutive patients were included in the study through retrospective chart review. A 5-port technique was utilized with the gastric sleeve being created using endostapler. Postoperatively, patients gradually progressed from clear liquid diet and oral rehydration salts to nutritional supplements over three days. By two weeks postoperatively, patients had progressed to a solid diet. SPSS was used for data entry and analysis. Body mass index (BMI) and weight in kg were determined. Results: From 100 patients, 17 were lost to follow-up less than a week into the postoperative period. Of the remaining, average age of the patients was 34.7 ±11.3 years at the time of surgery. The majority of patients were females (72 percentage). Mean preoperative and postoperative BMI was 45.3 ±10.4 kg/m2 and 35.0 ±10 kg/m2, respectively. Of the 83 patients, 62 were followed-up for longer than 1 month (average 419 days). For patients in this category, mean reduction in BMI was 10.3 ±6.5 kg/m2 with average weight loss of 34.3 ±18.2 kg. There were no mortalities associated with LSG. Conclusion: Laparoscopic sleeve gastrectomy is a safe and effective intervention in young Pakistani females with encouraging outcomes at a mean follow-up of over one year. (author)

  17. Finite element analysis of a novel pin-sleeve system for external fixation of distal limb fractures in horses.

    Science.gov (United States)

    Brianza, Stefano; Brighenti, Vittoria; Lansdowne, Jennifer L; Schwieger, Karsten; Bouré, Ludovic

    2011-11-01

    The transfixation pin cast (TPC) is an external skeletal fixation technique used to treat horses with distal limb fractures, but its use is often associated with pin-loosening and an increased risk of treatment failure. To address implant loosening, the pin sleeve cast system (PSC) was recently designed and consists of a pin-sleeve unit inserted into the bone. Each pin runs through a sleeve placed in the bone, making contact at two fixed points only within the sleeve. Each pin is attached to a ring embedded in a resin cast. In this report, the mechanical performance of a traditional TPC pin arrangement was compared with that of the PSC using validated finite element models of bone substitutes previously tested in vitro. The PSC resulted in a marked reduction in peak strain magnitude around the pins and a more even distribution of strain across the bone cortex. The two systems resulted in comparable proximal fragment displacement and had a similar stress concentration around bone defects during implant removal. The findings suggest that the PSC load transfer mechanism is effective even in geometrically complex structures like equine bones. Copyright © 2010 Elsevier Ltd. All rights reserved.

  18. Fretting and Corrosion Damage in Taper Adapter Sleeves for Ceramic Heads: A Retrieval Study.

    Science.gov (United States)

    MacDonald, Daniel W; Chen, Antonia F; Lee, Gwo-Chin; Klein, Gregg R; Mont, Michael A; Kurtz, Steven M; Cates, Harold E; Kraay, Matthew J; Rimnac, Clare M

    2017-09-01

    During revision surgery with a well-fixed stem, a titanium sleeve can be used in conjunction with a ceramic head to achieve better stress distribution across the taper surface. In vitro testing suggests that corrosion is not a concern in sleeved ceramic heads; however, little is known about the in vivo fretting corrosion of the sleeves. The purpose of this study was to investigate fretting corrosion in sleeved ceramic heads in retrieved total hip arthroplasties. Thirty-seven sleeved ceramic heads were collected during revision. The femoral heads and sleeves were implanted 0.0-3.3 years. The implants were revised predominantly for instability, infection, and loosening. Fifty percent of the retrievals were implanted during a primary surgery. Fretting corrosion was assessed using the Goldberg-Higgs semiquantitative scoring system. Mild-to-moderate fretting corrosion scores (score = 2-3) were observed in 92% of internal tapers, 19% of external tapers, and 78% of the stems. Severe fretting corrosion was observed in 1 stem trunnion that was previously retained during revision surgery and none of the retrieved sleeves. There was no difference in corrosion damage of sleeves used in primary or revision surgery. The fretting corrosion scores in this study were predominantly mild and lower than reported fretting scores of cobalt-chrome heads in metal-on-polyethylene bearings. Although intended for use in revisions, we found that the short-term in vivo corrosion behavior of the sleeves was similar in both primary and revision surgery applications. From an in vivo corrosion perspective, sleeves are a reasonable solution for restoring the stem taper during revision surgery. Copyright © 2017. Published by Elsevier Inc.

  19. Identification of characteristics and frequent scenarios of single-vehicle rollover crashes during pre-ballistic phase; part 1 - A descriptive study.

    Science.gov (United States)

    Kim, Taewung; Bose, Dipan; Foster, Jon; Bollapragada, Varun; Crandall, Jeff R; Clauser, Mark; Kerrigan, Jason R

    2017-10-01

    This study aimed to identify common patterns of pre-ballistic vehicle kinematics and roadway characteristics of real-world rollover crashes. Rollover crashes that were enrolled in the National Automotive Sampling System-Crashworthiness Data System (NASS-CDS) between the years 2000 and 2010 were analyzed. A descriptive analysis was performed to understand the characteristics of the pre-ballistic phase. Also, a frequency based pattern analysis was performed using a selection of NASS-CDS variables describing the pre-ballistic vehicle kinematics and roadway characteristics to rank common pathways of rollover crashes. Most case vehicles departed the road due to a loss of control/traction (LOC) (61%). The road departure with LOC was found to be 13.4 times more likely to occur with slippery road conditions compared to dry conditions. The vehicle was typically laterally skidding with yawing prior to a rollover (66%). Most case vehicles tripped over (82%) mostly at roadside/median (69%). The tripping force was applied to the wheels/tires (82%) from the ground (79%). The combination of these six most frequent attributes resulted in the most common scenario, which accounted for 26% of the entire cases. Large proportion of road departure with LOC (61%) implies electronic stability control (ESC) systems being an effective countermeasure for preventing single-vehicle rollover crashes. Furthermore, the correlation between the road departure with LOC and the reduced friction limit suggests the necessity of the performance evaluation of ESC under compromised road surface condition. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Comparison of two specimen retrieval techniques in laparoscopic sleeve gastrectomy: what is the role of endobag?

    Science.gov (United States)

    Shoar, Saeed; Aboutaleb, Shereen; Karem, Mohsen; Bashah, Moataz M; AlKuwari, Mohamed; Sargsyan, Davit; Saber, Alan A

    2017-12-01

    Laparoscopic sleeve gastrectomy (LSG) has become a popular stand-alone treatment for morbid obesity. However, removal of the gastric specimen could be a challenging step due to its large size relative to the width of the trocar site. We aimed to compare a simplified retrieval technique for extraction of the gastric specimen without an endobag with conventionally performed specimen retrieval using an endobag. A case-control study was conducted recruiting patients undergoing LSG. Patient's demographics, preoperative characteristics, intra-operative, and postoperative variables were compared between the two groups according to the technique of gastric specimen removal. A total of 193 patients (60.6% female) were enrolled into case (n = 100) and control groups (n = 93). Mean ± SD age and BMI of patients were 35.64 ± 11.84 years and 47.28 ± 8.22 Kg/m 2 , respectively with no significant difference between groups. Median (25th, 75th inter-quartile), extraction time was significantly reduced in the non-endobag group compared to the endobag group (3.5 [2.5-4.5] min vs. 6.5 [3.4-8.2] min, p = 0.03).Patients of both groups had similar intra-operative and trocar site complications (hernia and wound infection) (3% for endobag group and 3.3 % for non-endobag group). The median (25-75% [IQR]) LOS was also comparable between endobag and non-endobag patients (3[2-3] vs. 3[2-4] days, p = 0.84). No difference was observed between the two groups for weight loss and comorbidity resolution. Non-endobag technique for gastric specimen retrieval is safe and feasible with substantial saving in operative time and comparable intra-operative and postoperative outcomes to the conventional retrieval technique.

  1. Gastroesophageal Reflux Disease and Sleeve Gastrectomy.

    Science.gov (United States)

    Melissas, John; Braghetto, Italo; Molina, Juan Carlos; Silecchia, Gianfranco; Iossa, Angelo; Iannelli, Antonio; Foletto, Mirto

    2015-12-01

    Gastroesophageal reflux disease (GERD) and/or hiatus hernia (HH) are one of the most common disorders of the upper gastrointestinal tract. Despite the positive effect of sleeve gastrectomy (SG) regarding weight loss and improvement in obesity co-morbidities, there are concerns about the development of de novo gastroesophageal reflux disease or worsening the existing GERD after this bariatric operation. Furthermore, controversy exists on the consequences of SG in lower esophageal sphincter function and about the ideal procedure when a hiatus hernia is preoperatively diagnosed or discovered during the laparoscopic SG. This review systematically investigates the incidence, the pathophysiology of GERD and/or HH in morbidly obese individuals before and after SG, and the treatment options for concomitant HH repair during laparoscopic sleeve gastrectomy.

  2. Development of on line automatic separation device for apple and sleeve

    Science.gov (United States)

    Xin, Dengke; Ning, Duo; Wang, Kangle; Han, Yuhang

    2018-04-01

    Based on STM32F407 single chip microcomputer as control core, automatic separation device of fruit sleeve is designed. This design consists of hardware and software. In hardware, it includes mechanical tooth separator and three degree of freedom manipulator, as well as industrial control computer, image data acquisition card, end effector and other structures. The software system is based on Visual C++ development environment, to achieve localization and recognition of fruit sleeve with the technology of image processing and machine vision, drive manipulator of foam net sets of capture, transfer, the designated position task. Test shows: The automatic separation device of the fruit sleeve has the advantages of quick response speed and high separation success rate, and can realize separation of the apple and plastic foam sleeve, and lays the foundation for further studying and realizing the application of the enterprise production line.

  3. Esophageal adenocarcinoma five years after laparoscopic sleeve gastrectomy. A case report

    Directory of Open Access Journals (Sweden)

    Fernando Gabriel Wright

    2017-01-01

    Conclusion: We present a case of an esophageal adenocarcinoma five years after a laparoscopic sleeve gastrectomy for morbid obesity. There is need to better determine the relationship between sleeve gastrectomy and gastroesophageal reflux disease in order to prevent its related complications, such as esophageal adenocarcinoma.

  4. 78 FR 13853 - Federal Motor Vehicle Safety Standards; Denial of Petition for Rulemaking; Vehicle Rollover...

    Science.gov (United States)

    2013-03-01

    ... reduce rollover and other types of loss of control crashes. ESC systems use automatic computer- controlled braking of individual wheels to assist the driver in maintaining control in critical driving...

  5. Crimped braided sleeves for soft, actuating arm in robotic abdominal surgery.

    Science.gov (United States)

    Elsayed, Yahya; Lekakou, Constantina; Ranzani, Tommaso; Cianchetti, Matteo; Morino, Mario; Arezzo, Alberto; Menciassi, Arianna; Geng, Tao; Saaj, Chakravarthini M

    2015-01-01

    This paper investigates different types of crimped, braided sleeve used for a soft arm for robotic abdominal surgery, with the sleeve required to contain balloon expansion in the pneumatically actuating arm while it follows the required bending, elongation and diameter reduction of the arm. Three types of crimped, braided sleeves from PET (BraidPET) or nylon (BraidGreyNylon and BraidNylon, with different monofilament diameters) were fabricated and tested including geometrical and microstructural characterisation of the crimp and braid, mechanical tests and medical scratching tests for organ damage of domestic pigs. BraidPET caused some organ damage, sliding under normal force of 2-5 N; this was attributed to the high roughness of the braid pattern, the higher friction coefficient of polyethylene terephthalate (PET) compared to nylon, and the high frequency of the crimp peaks for this sleeve. No organ damage was observed for the BraidNylon, attributed to both the lower roughness of the braid pattern and the low friction coefficient of nylon. BraidNylon also required the lowest tensile force during its elongation to similar maximum strain as that of BraidPET, translating to low power requirements. BraidNylon is recommended for the crimped sleeve of the arm designed for robotic abdominal surgery.

  6. Resident education in robotic-assisted vertical sleeve gastrectomy: outcomes and cost-analysis of 411 consecutive cases.

    Science.gov (United States)

    Ecker, Brett L; Maduka, Richard; Ramdon, Andre; Dempsey, Daniel T; Dumon, Kristoffel R; Williams, Noel N

    2016-02-01

    Robotic technology is increasingly prevalent in bariatric surgery, yet there are national deficiencies in exposure of surgical residents to robotic techniques. The purpose of this study is to accurately characterize the perioperative outcomes of a resident teaching model using the robotic-assisted sleeve gastrectomy. University Hospital. We identified 411 consecutive patients who underwent robotic sleeve gastrectomy at our institution from a prospectively maintained administrative database. Perioperative morbidity, operative time, and supply cost of the procedure were analyzed. Mean operative time was 96.4±24.9 minutes; mean robot usage time was 63.9 minutes (range 30.0-122.0 min). Ninety-day morbidities included reoperation (0.72%), major bleeding complications (0.48%), staple line leak (0.24%), stricture (0.97%), need for blood transfusion (3.86%), surgical site infection (1.69%), deep vein thrombosis (0.48%), and pulmonary embolism (0.48%). Mortality was nil. The resident cohort achieved operative time plateaus after five consecutive cases. Subset analysis for fiscal year 2014 demonstrated significantly increased supply cost for robotic sleeve gastrectomy compared with its laparoscopic equivalent. Robotic-assisted sleeve gastrectomy can be instituted as a model for resident robotic education with rates of morbidity and operative times equivalent to historical laparoscopic controls. The robot's enhanced ergonomics and its opportunity for resident education must be weighed against its increased supply cost. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  7. Design of a Soft Robotic Elbow Sleeve with Passive and Intent-Controlled Actuation

    Directory of Open Access Journals (Sweden)

    Tze Hui Koh

    2017-10-01

    Full Text Available The provision of continuous passive, and intent-based assisted movements for neuromuscular training can be incorporated into a robotic elbow sleeve. The objective of this study is to propose the design and test the functionality of a soft robotic elbow sleeve in assisting flexion and extension of the elbow, both passively and using intent-based motion reinforcement. First, the elbow sleeve was developed, using elastomeric and fabric-based pneumatic actuators, which are soft and lightweight, in order to address issues of non-portability and poor alignment with joints that conventional robotic rehabilitation devices are faced with. Second, the control system was developed to allow for: (i continuous passive actuation, in which the actuators will be activated in cycles, alternating between flexion and extension; and (ii an intent-based actuation, in which user intent is detected by surface electromyography (sEMG sensors attached to the biceps and triceps, and passed through a logic sequence to allow for flexion or extension of the elbow. Using this setup, the elbow sleeve was tested on six healthy subjects to assess the functionality of the device, in terms of the range of motion afforded by the device while in the continuous passive actuation. The results showed that the elbow sleeve is capable of achieving approximately 50% of the full range of motion of the elbow joint among all subjects. Next, further experiments were conducted to test the efficacy of the intent-based actuation on these healthy subjects. The results showed that all subjects were capable of achieving electromyography (EMG control of the elbow sleeve. These preliminary results show that the elbow sleeve is capable of carrying out continuous passive and intent-based assisted movements. Further investigation of the clinical implementation of the elbow sleeve for the neuromuscular training of neurologically-impaired persons, such as stroke survivors, is needed.

  8. The influence of occupant anthropometry and seat position on ejection risk in a rollover.

    Science.gov (United States)

    Atkinson, Theresa; Fras, Andrew; Telehowski, Paul

    2010-08-01

    During rollover crashes, ejection increases an occupant's risk of severe to fatal injury as compared to risks for those retained in the vehicle. The current study examined whether occupant anthropometry might influence ejection risk. Factors such as restraint use/disuse, seating position, vehicle type, and roll direction were also considered in the analysis. The current study examined occupant ejections in 10 years of National Automotive Sampling System (NASS) single-event rollovers of passenger vehicles and light trucks. Statistical analysis of unweighted and weighted ejection data was carried out. No statistically significant differences in ejection rates were found based on occupant height, age, or body mass index. Drivers were ejected significantly more frequently than other occupants: 62 percent of unrestrained drivers were ejected vs. 51 percent unrestrained right front occupants. Second row unrestrained occupants were ejected at rates similar to right front-seated occupants. There were no significant differences in ejection rates for near- vs. far-side occupants. These data suggest that assessment of ejection prevention systems using either a 50th or 5th percentile adult anthropomorphic test dummy (ATD) might provide a reasonable measure of system function for a broad range of occupants. They also support the development of ejection mitigation technologies that extend beyond the first row to protect occupants in rear seat positions. Future studies should consider potential interaction effects (i.e., occupant size and vehicle dimensions) and the influence of occupant size on ejection risk in non-single-event rollovers.

  9. Physical modelling of LNG rollover in a depressurized container filled with water

    Science.gov (United States)

    Maksim, Dadonau; Denissenko, Petr; Hubert, Antoine; Dembele, Siaka; Wen, Jennifer

    2015-11-01

    Stable density stratification of multi-component Liquefied Natural Gas causes it to form distinct layers, with upper layer having a higher fraction of the lighter components. Heat flux through the walls and base of the container results in buoyancy-driven convection accompanied by heat and mass transfer between the layers. The equilibration of densities of the top and bottom layers, normally caused by the preferential evaporation of Nitrogen, may induce an imbalance in the system and trigger a rapid mixing process, so-called rollover. Numerical simulation of the rollover is complicated and codes require validation. Physical modelling of the phenomenon has been performed in a water-filled depressurized vessel. Reducing gas pressure in the container to levels comparable to the hydrostatic pressure in the water column allows modelling of tens of meters industrial reservoirs using a 20 cm laboratory setup. Additionally, it allows to model superheating of the base fluid layer at temperatures close the room temperature. Flow visualizations and parametric studies are presented. Results are related to outcomes of numerical modelling.

  10. Left lower lobe sleeve lobectomy for lung cancer using the Da Vinci surgical system.

    Science.gov (United States)

    Zhao, Yandong; Jiao, Wenjie; Ren, Xiaoyang; Zhang, Liangdong; Qiu, Tong; Fu, Bo; Wang, Lei

    2016-04-12

    Despite the robotic surgery is widely applied, sleeve lobectomy for lung cancer using the Da Vinci surgical system is still less performed. We described a sleeve lobectomy for adenocarcinoma located at the left lower lobe using the Da Vinci surgical system. A case of 57-year old female referred to our hospital. Computed tomography scan showed an occupation located at the left lower lobe and adenocarcinoma project from the lobe bronchus was diagnosed by bronchoscope examination. A sleeve lobectomy was performed using the Da Vinci surgical system and the postoperative recovery was uneventful. Robotic thoracic surgery is feasible to perform sleeve lobectomy inspite of inadequate experience.

  11. New TA Index-Based Rollover Prevention System for Electric Vehicles

    OpenAIRE

    Xiang Liu; Min Xu; Mian Li

    2015-01-01

    In addition to clean transportation and energy savings, electric vehicles can inherently offer better performance in the field of active safety and dynamic stability control, thanks to the superior fast and accurate control characteristics of electric motors. With the novel wheel status parameter TA for electric vehicles proposed by the authors in an earlier publication, a new TA index (TAI)-based rollover prevention method is presented in this paper to improve the driving performance of EV...

  12. Dysphagia after vertical sleeve gastrectomy: Evaluation of risk factors and assessment of endoscopic intervention

    OpenAIRE

    Nath, Anand; Yewale, Sayali; Tran, Tung; Brebbia, John S; Shope, Timothy R; Koch, Timothy R

    2016-01-01

    AIM To evaluate the risks of medical conditions, evaluate gastric sleeve narrowing, and assess hydrostatic balloon dilatation to treat dysphagia after vertical sleeve gastrectomy (VSG). METHODS VSG is being performed more frequently worldwide as a treatment for medically-complicated obesity, and dysphagia is common post-operatively. We hypothesize that post-operative dysphagia is related to underlying medical conditions or narrowing of the gastric sleeve. This is a retrospective, single insti...

  13. Influence of patellofemoral pain syndrome on plantar pressure in the foot rollover process during gait

    Directory of Open Access Journals (Sweden)

    Sandra Aliberti

    2011-01-01

    Full Text Available BACKGROUND: Patellofemoral Pain Syndrome is one of the most common knee disorders among physically active young women. Despite its high incidence, the multifactorial etiology of this disorder is not fully understood. OBJECTIVES: To investigate the influence of Patellofemoral Pain Syndrome on plantar pressure distribution during the foot rollover process (i.e., the initial heel contact, midstance and propulsion phases of the gait. MATERIALS AND METHODS: Fifty-seven young adults, including 22 subjects with Patellofemoral Pain Syndrome (30 ± 7 years, 165 ± 9 cm, 63 ± 12 kg and 35 control subjects (29 ± 7 years, 164 ± 8 cm, 60 ± 11 kg, volunteered for the study. The contact area and peak pressure were evaluated using the Pedar-X system (Novel, Germany synchronized with ankle sagittal kinematics. RESULTS: Subjects with Patellofemoral Pain Syndrome showed a larger contact area over the medial (p = 0.004 and central (p = 0.002 rearfoot at the initial contact phase and a lower peak pressure over the medial forefoot (p = 0.033 during propulsion when compared with control subjects. CONCLUSIONS: Patellofemoral Pain Syndrome is related to a foot rollover pattern that is medially directed at the rearfoot during initial heel contact and laterally directed at the forefoot during propulsion. These detected alterations in the foot rollover process during gait may be used to develop clinical interventions using insoles, taping and therapeutic exercise to rehabilitate this dysfunction.

  14. Utility of the balloon-overtube-assisted modified over-the-wire stenting technique to treat post-sleeve gastrectomy complications.

    Science.gov (United States)

    Ponte, Ana; Pinho, Rolando; Proença, Luísa; Silva, Joana; Rodrigues, Jaime; Sousa, Mafalda; Silva, João Carlos; Carvalho, João

    2017-06-16

    To describe a modified technique of deployment of stents using the overtube developed for balloon-assisted enteroscopy in post-sleeve gastrectomy (SG) complications. Between January 2010 and December 2015, all patients submitted to an endoscopic stenting procedure to treat a post-SG stenosis or leakage were retrospectively collected. Procedures from patients in which the stent was deployed using the balloon-overtube-assisted modified over-the-wire (OTW) stenting technique were described. The technical success, corresponding to proper placement of the stent in the stomach resulting in exclusion of the SG leak or the stenosis, was evaluated. Complications related to stenting were also reported. Five procedures were included to treat 2 staple line leaks and 3 stenoses. Two types of stents were used, including a fully covered self-expandable metal stent designed for the SG anatomy (Hanarostent, ECBB-30-240-090; M.I. Tech, Co., Ltd, Seoul, South Korea) in 4 procedures and a biodegradable stent (BD stent 019-10A-25/20/25-080, SX-ELLA, Hradec Kralove, Czech Republic) in the remaining procedure. In all cases, an overtube was advanced with the endoscope through the SG to the duodenum. After placement of the guidewire and removal of the endoscope, the stent was easily advanced through the overtube. The overtube was pulled back and the stent was successfully deployed under fluoroscopic guidance. Technical success was achieved in all patients. The adoption of a modified technique of deployment of OTW stents using an overtube may represent an effective option in the approach of SG complications.

  15. Numerical and experimental investigation of flow and heat transfer in a T-junction with thermal sleeve

    International Nuclear Information System (INIS)

    Wu Hailing; Chen Tingkuan; Wang Haijun; Luo Yushan; Mao Qing; Zhang Yixiong

    2002-01-01

    Numerical simulations were performed with the commercial computational fluid dynamics (CFD) package FLUENT 5.3 to investigate the thermal-hydraulic phenomena of thermal shock, which is caused by non-isothermal turbulent jet into crossflow in a T-junction with thermal sleeve in the pressurized water reactor (PWR) cooling systems. In allusion to the thermal sleeve configuration with vent holes and lower collar, two typical cases with jet-to-mainstream velocity ratios of 0.05 and 0.5 were computed. Experimental studies were carried out to determine the heat transfer characteristics for the main pipe and the annulus between the nozzle and the thermal sleeve. The calculations well matches the experimental data. The results indicated that the protective action of the thermal sleeve against thermal shock loading is dependent on both the sleeve geometry and the velocity ratio, obtaining improvement with appropriate lower velocity ratios. In addition, optimal flow rates and partial sizes of the thermal sleeve were discussed to reduce the thermal shock

  16. [Perioperative managment of laparoscopic sleeve gastrectomy].

    Science.gov (United States)

    Chang, Xu-sheng; Yin, Kai; Wang, Xin; Zhuo, Guang-zuan; Ding, Dan; Guo, Xiang; Zheng, Cheng-zhu

    2013-10-01

    To summarize the surgical technique and perioperative management of laparoscopic sleeve gastrectomy (LSG). A total of 57 morbid obesity patients undergoing LSG surgery from May 2010 to December 2012 were enrolled in the study, whose clinical data in perioperative period were analyzed retrospectively. These patients had more than 1 year of follow-up. All the patients received preoperative preparation and postoperative management, and postoperative excess weight loss(EWL%) and improvement of preoperative complications was evaluated. All the cases completed the operation under laparoscopy, except 1 case because of the abdominal extensive adhesion. The average operation time was(102.0±15.2) min and the mean intraoperative blood loss (132.3±45.6) ml. Of 2 postoperative hemorrhage patients, 1 case received conservative treatment, and another one underwent laparoscopic exploration. The EWL% at 3 months, 6 months and 1 year after procedure was (54.9±13.8)%, (79.0±23.6)% and (106.9±25.1)% respectively. The preoperative complications were improved in some degree. There were no operative death, and anastomotic leak, anastomotic stenosis, or surgical site infection occurred. LSG is a safe and effective surgical technique, whose safety and efficacy may be increased by improving the perioperative management.

  17. Experimental Qualification of the Sleeved Pin Multilink Attachment for Divertor PFC's

    International Nuclear Information System (INIS)

    Poutanen, J.; McCallum, A.; Turner, A.; Merola, M.

    2006-01-01

    The latest design for connecting the limited life ITER divertor plasma facing components (PFC's) to the reusable cassette body is the so called sleeved pin multilink attachment. The connection is made by expanding a 43 mm diameter hollow AlBr pin inside the fixation holes of components of the cassette body and PFC by a swaging process. The multilink is an easy, safe and fast assembly method, but the original dismantling method of drilling out the pin was found troublesome. Therefore, in the latest attachment design a thin sleeve is incorporated between the pin and the holes, which makes it possible to dismantle the joint by simply pulling out the pin and sleeve sequentially. Experimental qualification of the new sleeved design is now proceeding. The aim of the experimental qualification is to prove that the sleeved design meets the requirements of load carrying capability, clearance free connection, and easy and safe removal. Associated analytical studies were performed to develop and verify theoretical models and correlations for use in design. Results from the experimental qualification will provide reference information for developing tools for making and removing the connection. Theoretical finite element models in association with the results of earlier test campaigns with nonsleeved design were used to determine pin expansion parameters. The expansion parameters were verified with plate-pin tests measuring contact pressures produced by pin expansion. The plate-pin tests were also used to demonstrate the feasibility of pin removal and develop pin removal methodology. The mechanical capabilities of the connection design are being examined with test series of cyclic tensile loading plus articulation-induced loading of a single connection mock-up. Remaking properties of the attachment are being studied with multiple swaging and removing of the pin into the fixation holes. Finally the dismantling of the connection will be examined with full length pin extraction

  18. Microfabricated sleeve devices for chemical reactions

    Science.gov (United States)

    Northrup, M. Allen

    2003-01-01

    A silicon-based sleeve type chemical reaction chamber that combines heaters, such as doped polysilicon for heating, and bulk silicon for convection cooling. The reaction chamber combines a critical ratio of silicon and non-silicon based materials to provide the thermal properties desired. For example, the chamber may combine a critical ratio of silicon and silicon nitride to the volume of material to be heated (e.g., a liquid) in order to provide uniform heating, yet low power requirements. The reaction chamber will also allow the introduction of a secondary tube (e.g., plastic) into the reaction sleeve that contains the reaction mixture thereby alleviating any potential materials incompatibility issues. The reaction chamber may be utilized in any chemical reaction system for synthesis or processing of organic, inorganic, or biochemical reactions, such as the polymerase chain reaction (PCR) and/or other DNA reactions, such as the ligase chain reaction, which are examples of a synthetic, thermal-cycling-based reaction. The reaction chamber may also be used in synthesis instruments, particularly those for DNA amplification and synthesis.

  19. Full-scale tank car rollover tests - survivability of top fittings and top fittings protective structures : final report.

    Science.gov (United States)

    2016-05-01

    Full-scale rollover crash tests were performed on three non-pressure tank carbodies to validate previous analytical work and : determine the effectiveness of two different types of protective structures in protecting the top fittings. The tests were ...

  20. Development of a high speed extrusion concept using a floating screw sleeve for solid-melt-separation

    Science.gov (United States)

    Karrenberg, Gregor; Wortberg, Johannes

    2015-05-01

    The High-Speed-S-Truder with floating screw sleeve is an alternative extrusion concept with solid-melt-separation. A fairly conventional 35 mm screw with a length of 21 D, which is accelerated by a 75 kW gearless, water cooled synchronous drive, conveys the resin into a 60 mm screw sleeve with a length of 10 D. Inside the sleeve the material is plasticizied and discharged into the outer screw channel of the sleeve through radial bores. Only the solid bed remains inside. The development of a melt pool - and thus a decrease of the plasticizing capacity - is avoided. The sleeve is rotated by drag forces only (approximately 10 - 15 % of the screw speed). Due to the low speed of the screw sleeve molten material is conveyed to a 4 D Dynamic Mixing Ring in a gentle manner. The DMRs floating ring and the screw sleeve are directly coupled. The granules in the screw channel are stopped by a barrier on the screw in front of the mixing device. So nearly no unmelted material can pass the system. For temperature management in the plastification and mixing zone a 3-zone heating/air-cooling system is used. Various kinds of experiments with the High-Speed S-Truder were conducted. Reachable throughputs with different types of material (LDPE, LLDPE, PP, PS) have been tested. Also three screw geometries, which are mainly varying in the channel depth, were compared. Experimental results and theoretical background will be described in this paper.

  1. Silicon-based sleeve devices for chemical reactions

    Science.gov (United States)

    Northrup, M. Allen; Mariella, Jr., Raymond P.; Carrano, Anthony V.; Balch, Joseph W.

    1996-01-01

    A silicon-based sleeve type chemical reaction chamber that combines heaters, such as doped polysilicon for heating, and bulk silicon for convection cooling. The reaction chamber combines a critical ratio of silicon and silicon nitride to the volume of material to be heated (e.g., a liquid) in order to provide uniform heating, yet low power requirements. The reaction chamber will also allow the introduction of a secondary tube (e.g., plastic) into the reaction sleeve that contains the reaction mixture thereby alleviating any potential materials incompatibility issues. The reaction chamber may be utilized in any chemical reaction system for synthesis or processing of organic, inorganic, or biochemical reactions, such as the polymerase chain reaction (PCR) and/or other DNA reactions, such as the ligase chain reaction, which are examples of a synthetic, thermal-cycling-based reaction. The reaction chamber may also be used in synthesis instruments, particularly those for DNA amplification and synthesis.

  2. High-Mobility Multipurpose Wheeled Vehicle Rollover Accidents and Injuries to U.S. Army Soldiers by Reported Occupant Restraint Use, 1992-2013.

    Science.gov (United States)

    Lo, Michael C; Giffin, Robert P; Pakulski, Kraig A; Davis, W Sumner; Bernstein, Stephen A; Wise, Daniel V

    2017-05-01

    The high-mobility multipurpose wheeled vehicle (HMMWV) is a light military tactical vehicle. During Operation Iraqi Freedom and Operation Enduring Freedom, the U.S. Army modified the HMMWV into a combat vehicle by adding vehicle armor, which made the vehicle more difficult to control and more likely to roll over. Consequently, reports of fatal rollover accidents involving up-armored HMMWVs began to accumulate during the up-armoring period (August 2003 to April 2005). Furthermore, the lack of occupant restraint use prevalent in a predominantly young, male, and enlisted military population compounded the injuries resulting from these accidents. In this retrospective case series analysis, we describe the characteristics of U.S. Army HMMWV rollover accidents, occupants, and injuries reported worldwide from fiscal year 1992 to 2013 based on reported occupant restraint use. We conducted all analyses using Microsoft Excel 2010 and SAS version 9.1. Because this analysis does not constitute human subjects research, no institutional review board review was required. First, we obtained U.S. Army HMMWV accident records from the U.S. Army Combat Readiness Center, and selected those records indicating a HMMWV rollover had occurred. Next, we successively deduplicated the records at the accident, vehicle, occupant, and injury levels for descriptive analysis of characteristics at each level. For each occupant position, we calculated relative, attributable, and population attributable risks of nonfatal and fatal injury based on reported occupant restraint use. Finally, we analyzed body part injured and nature of injury to characterize the injury patterns that HMMWV occupants in each position sustained based on restraint use. We performed a χ 2 test of homogeneity to assess differences in injury patterns between restrained and unrestrained occupants. A total of 819 U.S. Army HMMWV rollover accidents worldwide were reported from October 1991 through May 2013 involving 821 HMMWVs and

  3. Study on grout-filled coupling steel sleeve; Kokan sleeve wo mochiita grout jutenshiki tekkin tsugite ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Y. [Osaka University, Osaka (Japan)

    1997-06-01

    Newly designed grout-filled coupling sleeve is discussed, which uses as the sleeve an electric resistance welded tube with protrusions formed in a checker pattern on its inner wall and is capable of using various premixed grouting materials available on the market. Specimens are subjected to uniaxial tensile loading and positive/negative cyclic loading, and the impact of various factors on the basic performance of the specimens and their stress/distortion characteristics at local spots in the reinforcing bar are disclosed. In the positive/negative cyclic loading in the plastic region, however, such findings are not obtained. In view of the stress/distortion characteristics at local spots in the reinforcing bar, a method is proposed for estimating the coupling strength and fracture type. A method for estimating the deformation behavior of the coupling, however, is not proposed. Investigations are conducted into the manufacture and installation of the grout holding framework, coupling fixing jigs, plugs, etc., and it is found that precasting should be studied in the future. 38 refs., 156 figs., 30 tabs.

  4. Sleeve gastrectomy effects on hunger, satiation, and gastrointestinal hormone and motility responses after a liquid meal test.

    Science.gov (United States)

    Mans, Esther; Serra-Prat, Mateu; Palomera, Elisabet; Suñol, Xavier; Clavé, Pere

    2015-09-01

    The relation between hunger, satiation, and integrated gastrointestinal motility and hormonal responses in morbidly obese patients after sleeve gastrectomy has not been determined. The objective was to assess the effects of sleeve gastrectomy on hunger, satiation, gastric and gallbladder motility, and gastrointestinal hormone response after a liquid meal test. Three groups were studied: morbidly obese patients (n = 16), morbidly obese patients who had had sleeve gastrectomy (n = 8), and nonobese patients (n = 16). The participants fasted for 10 h and then consumed a 200-mL liquid meal (400 kcal + 1.5 g paracetamol). Fasting and postprandial hunger, satiation, hormone concentrations, and gastric and gallbladder emptying were measured several times over 4 h. No differences were observed in hunger and satiation curves between morbidly obese and nonobese groups; however, sleeve gastrectomy patients were less hungry and more satiated than the other groups. Antrum area during fasting in morbidly obese patients was statistically significant larger than in the nonobese and sleeve gastrectomy groups. Gastric emptying was accelerated in the sleeve gastrectomy group compared with the other 2 groups (which had very similar results). Gallbladder emptying was similar in the 3 groups. Sleeve gastrectomy patients showed the lowest ghrelin concentrations and higher early postprandial cholecystokinin and glucagon-like peptide 1 peaks than did the other participants. This group also showed an improved insulin resistance pattern compared with morbidly obese patients. Sleeve gastrectomy seems to be associated with profound changes in gastrointestinal physiology that contribute to reducing hunger and increasing sensations of satiation. These changes include accelerated gastric emptying, enhanced postprandial cholecystokinin and glucagon-like peptide 1 concentrations, and reduced ghrelin release, which together may help patients lose weight and improve their glucose metabolism after

  5. Preoperative endoscopy may reduce the need for revisional surgery for gastro-oesophageal reflux disease following laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Madhok, B M; Carr, W R J; McCormack, C; Boyle, M; Jennings, N; Schroeder, N; Balupuri, S; Small, P K

    2016-08-01

    Laparoscopic sleeve gastrectomy is a safe and effective bariatric operation, but postoperative reflux symptoms can sometimes necessitate revisional surgery. Roux-en-Y gastric bypass is the preferred operation in morbidly obese patients with gastro-oesophageal reflux disease. In 2011, we introduced preoperative endoscopy to assess for hiatus hernia or evidence of oesophagitis in conjunction with an assessment of gastro-oesophageal reflux symptoms for all patients undergoing bariatric surgery with a view to avoid sleeve gastrectomy for these patients. A prospectively maintained database was used to identify patients who underwent sleeve gastrectomy before and after we changed the unit policy. The need for revisional surgery in patients with troublesome gastro-oesophageal reflux disease was examined. Prior to 2011, 130 patients underwent sleeve gastrectomy, and 11 (8.5%) of them required conversion to Roux-en-Y gastric bypass for symptomatic reflux disease. Following the policy change, 284 patients underwent sleeve gastrectomy, and to date, only five (1.8%) have required revisional surgery (p = 0.001). Baseline demographics were comparable between the groups, and average follow-up period was 47 and 33 months, respectively, for each group. Preoperative endoscopy and a detailed clinical history regarding gastro-oesophageal reflux symptoms may improve patient selection for sleeve gastrectomy. Avoiding sleeve gastrectomy in patients with reflux disease and/or hiatus hernia may reduce the incidence of revisional surgery. © 2016 World Obesity.

  6. Elastic Knee Sleeves Limit Anterior Tibial Translation in Healthy Females

    Directory of Open Access Journals (Sweden)

    Robert Csapo, Simona Hosp, Ramona Folie, Robert Eberle, Michael Hasler, Werner Nachbauer

    2016-03-01

    Full Text Available Knee sleeves or braces represent auxiliary tools that have repeatedly been used by athletes, in an attempt to increase knee stability and, thus, reduce the risk of (recurrent ligamentous injuries. Since ACL injuries typically occur in situations involving either torsion or hyperextension of the knee, it has been speculated that braces might protect the ACL by countering excessive anterior translation of the tibia with respect to the femur (Beynnon et al., 1997. However, the preponderance of in vivo studies to test this hypothesis was performed in cohorts of patients suffering from existent ligamentous (Branch et al., 1988; Colville et al., 1986 or other knee injury (Beynnon et al., 1997; Fleming et al., 2000. This complicates the extrapolation of results to healthy subjects. Further, the braces used in these studies were mostly rigid constructs that consisted of either uni- or bilateral hinged bars (Rishiraj et al., 2009. Such braces might hinder performance (Veldhuizen et al., 1991 and would be rejected by the vast majority of healthy athletes. For these reasons, we would like to use this letter to the editor to report the results of our experiments investigating whether a relatively light elastic knee sleeve would limit the degree of anterior tibial translation in computerized arthrometry tests as performed in a sample of non-injured subjects. We recruited ten female college students (age: 23.4 ± 3.2 yrs, height: 1.68 ± 0.05 m, mass: 59.9 ± 5.5 kg who were free of acute or previous injury or any form of orthopaedic disease of the knee joints. The anterior displacement of the tibia was measured using the GNRB® computerized arthrometer (GeNouRob, Laval, France. With subjects lying in the supine position, the lower leg was firmly fixed with plastic caps mounted over the ankle joint and patella. An electrical pressure pad then exerted increasing pressure of up to 250 N on the calf, while a motion sensor, which was positioned on the ventral

  7. One-stoma carinoplasty: right upper sleeve lobectomy with hemicarinectomy for resection of right-tracheobronchial-angle tumors.

    Science.gov (United States)

    Kaya, Seyda Ors; Sevinc, Serpil; Ceylan, Kenan Can; Usluer, Ozan; Unsal, Saban

    2013-01-01

    Tracheobronchial-angle tumors involve the right main bronchus, the right upper lobar bronchus, and the lateral wall of the lower trachea. Resecting these tumors is one of the most complex procedures in thoracic surgery. In cases of high-caliber mismatch, the selection of a suitable anastomotic technique can be challenging. We found that our use of a one-stoma carinoplasty technique overcame high-caliber mismatch after the resection of these tumors. From 2009 through 2012, 8 men (mean age, 59 ± 6.2 yr; range, 46-66 yr) underwent complete resection of non-small-cell right-tracheobronchial-angle tumors at our institution. In every case, right upper sleeve lobectomy, wedge carinal resection, and one-stoma carinoplasty were applied. After tumor resection, one patient with hemoptysis and bronchopleural fistula underwent a completion pneumonectomy and died 10 days postoperatively. Bronchoscopy was necessary in 2 patients who had atelectasis in the contralateral lung. At a mean follow-up duration of 19.43 ± 8.4 months (range, 0.2-27.1 mo), 6 patients were alive and free of disease. We conclude that our one-stoma carinoplasty technique enables the resection of tumors at the right tracheobronchial angle, with acceptable morbidity and mortality rates. This method saves the unaffected part of the ipsilateral lung and can overcome high-caliber mismatch. Because of these and other advantages, we suggest that using our method first might preclude having to perform a right carinal sleeve pneumonectomy or using Barclay's method.

  8. Intraoperative leak testing has no correlation with leak after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Sethi, Monica; Zagzag, Jonathan; Patel, Karan; Magrath, Melissa; Somoza, Eduardo; Parikh, Manish S; Saunders, John K; Ude-Welcome, Aku; Schwack, Bradley F; Kurian, Marina S; Fielding, George A; Ren-Fielding, Christine J

    2016-03-01

    Staple line leak is a serious complication of sleeve gastrectomy. Intraoperative methylene blue and air leak tests are routinely used to evaluate for leak; however, the utility of these tests is controversial. We hypothesize that the practice of routine intraoperative leak testing is unnecessary during sleeve gastrectomy. A retrospective cohort study was designed using a prospectively collected database of seven bariatric surgeons from two institutions. All patients who underwent sleeve gastrectomy from March 2012 to November 2014 were included. The performance of intraoperative leak testing and the type of test (air or methylene blue) were based on surgeon preference. Data obtained included BMI, demographics, comorbidity, presence of intraoperative leak test, result of test, and type of test. The primary outcome was leak rate between the leak test (LT) and no leak test (NLT) groups. SAS version 9.4 was used for univariate and multivariate analyses. A total of 1550 sleeve gastrectomies were included; most were laparoscopic (99.8%), except for one converted and two open cases. Routine intraoperative leak tests were performed in 1329 (85.7%) cases, while 221 (14.3%) did not have LTs. Of the 1329 cases with LTs, there were no positive intraoperative results. Fifteen (1%) patients developed leaks, with no difference in leak rate between the LT and NLT groups (1 vs. 1%, p = 0.999). After adjusting for baseline differences between the groups with a propensity analysis, the observed lack of association between leak and intraoperative leak test remained. In this cohort, leaks presented at a mean of 17.3 days postoperatively (range 1-67 days). Two patients with staple line leaks underwent repeat intraoperative leak testing at leak presentation, and the tests remained negative. Intraoperative leak testing has no correlation with leak due to laparoscopic sleeve gastrectomy and is not predictive of the later development of staple line leak.

  9. Design improvement for partial penetration welds of Pressurizer heater sleeves to head junctures

    International Nuclear Information System (INIS)

    Kim, Jin-Seon; Lee, Kyoung-Jin; Park, Tae-Jung; Kim, Moo-Yong

    2007-01-01

    ASME Code, Section III allows partial penetration welds for openings for instrumentation on which there are substantially no piping reactions and requires to have interference fit or limited diametral clearance between nozzles and vessel penetrations for the partial penetration welds. Pressurizer heater sleeves are nonaxisymmetrically attached on the hill-side of bottom head by partial penetration welds. The excessive stresses in the partial penetration weld regions of the heater sleeves are induced by pressure and thermal transient loads and also by the deformation due to manual welding process. The purpose of this study is 1) to improve design for the partial penetration welds between heater sleeves to head junctures, 2) to demonstrate the structural integrity according to the requirements of ASME Code, Section III and 3) to improve welding procedure considering the proposed design

  10. Experimental and numerical studies of various thermal sleeves subjected to severe cyclic thermal shocks

    International Nuclear Information System (INIS)

    Masson, J.C.; Moinereau, D.

    1990-01-01

    During the first operating years of nuclear power plants of different countries, damage was encountered on thermal sleeves used as nozzle protection. Following this discovery studies were initiated to determine the causes and to find solutions. At first a problem of vibration was found and easily solved by reducing gaps and reinforcing the welding of the sleeves. But preliminary tests with cyclic thermal shocks showed a risk of fatigue crack initiation and propagation both in the sleeve fixation and in the nozzle. Therefore a large research and development program was led principally by EDF laboratories of Les Renardieres, to demonstrate the absence of nocivity of thermal shocks during the plants life time [fr

  11. Computed tomography of cystic nerve root sleeve dilatation.

    Science.gov (United States)

    Neave, V C; Wycoff, R R

    1983-10-01

    A case of cystic nerve root sleeve dilatation in the lumbar area associated with a chronic back pain syndrome is presented. Prominent computed tomography (CT) findings include: (a) rounded masses in the region of the foramina isodense with cerebrospinal fluid in the subarachnoid space; (b) associated asymmetry of epidural fat distribution; (c) enlargement of the neural foramina in axial sections with scalloped erosion of the adjacent posteriolateral vertebral body, pedicle, and pedicular-laminar junction with preservation of cortex and without bony sclerosis or infiltrative appearance; (d) prominent or ectatic dural sac with lack of usual epidural landmarks between the sac and vertebral body; and (e) multilevel abnormalities throughout the entire lumbar region. Myelographic and CT correlations are demonstrated with a review of the literature. A discussion of the various cystic abnormalities involving nerve root sheaths is undertaken in an attempt to clarify the confusing nomenclature applied to nerve root sleeve pathology.

  12. Retained copper sleeve of cu-T IUCD

    African Journals Online (AJOL)

    Dr Adaji

    Case Report. A 47-year old para 7+1 five alive presented at the. Reproductive Health center for removal of a copper-T intrauterine contraceptive device following a clinical diagnosis of pelvic inflammatory disease. The device was inserted the previous year. After easy removal , it was observed that the copper sleeve on one ...

  13. 3D finite element modeling of in-service sleeve repair welding of gas pipelines

    International Nuclear Information System (INIS)

    Alian, Ahmed R.; Shazly, Mostafa; Megahed, Mohammad M.

    2016-01-01

    The present work investigates the influence of welding sequence and scheme on residual stresses induced during in-service sleeve repair welding of gas pipelines. For this purpose, a 3D thermo-mechanical FE analysis is conducted on an 8″-Schedule-20, API 5L-X65 steel pipe. Two welding sequences for the sleeve-pipe circumferential fillet welds are compared in the present study: sequential welding in which one side of the sleeve is welded first and then the other side is welded by the same welder, and simultaneous welding in which both sides of the sleeve are welded concurrently by two welders. Within the simultaneous welding sequence, four different welding schemes, designed to investigate the influence of the number of welders and welding directions on residual stresses, are investigated. The results show that the sequential welding sequence induces less residual stresses and distortions. Within the simultaneous welding sequence, the back-step welding scheme is found to induce the least average residual stresses as compared to other welding schemes. - Highlights: • We model in-service sleeve repair welding using 3D FE. • Model was validated through comparison with existing experimental results. • The study presents results on the effect of both welding sequence and welding scheme on the resulting residual stresses. • Sequential welding sequence generates lower residual stresses than simultaneous welding sequence. • Back-step welding scheme generates the lowest average residual stresses along the pipe circumference.

  14. Foot roll-over evaluation based on 3D dynamic foot scan.

    Science.gov (United States)

    Samson, William; Van Hamme, Angèle; Sanchez, Stéphane; Chèze, Laurence; Van Sint Jan, Serge; Feipel, Véronique

    2014-01-01

    Foot roll-over is commonly analyzed to evaluate gait pathologies. The current study utilized a dynamic foot scanner (DFS) to analyze foot roll-over. The right feet of ten healthy subjects were assessed during gait trials with a DFS system integrated into a walkway. A foot sole picture was computed by vertically projecting points from the 3D foot shape which were lower than a threshold height of 15 mm. A 'height' value of these projected points was determined; corresponding to the initial vertical coordinates prior to projection. Similar to pedobarographic analysis, the foot sole picture was segmented into anatomical regions of interest (ROIs) to process mean height (average of height data by ROI) and projected surface (area of the projected foot sole by ROI). Results showed that these variables evolved differently to plantar pressure data previously reported in the literature, mainly due to the specificity of each physical quantity (millimeters vs Pascals). Compared to plantar pressure data arising from surface contact by the foot, the current method takes into account the whole plantar aspect of the foot, including the parts that do not make contact with the support surface. The current approach using height data could contribute to a better understanding of specific aspects of foot motion during walking, such as plantar arch height and the windlass mechanism. Results of this study show the underlying method is reliable. Further investigation is required to validate the DFS measurements within a clinical context, prior to implementation into clinical practice. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. The appearance of a lurking ligament in Laparoscopic Sleeve Gastrectomy; Posterior Gastric Ligament

    Directory of Open Access Journals (Sweden)

    Mutlu Ünver

    2017-03-01

    Full Text Available Objective: The aim of this study was to demonstrate a lurking ligament and its various formation types and to mention the importance of this ligament in Laparoscopic sleeve gastrectomy Methods: One hundred and twelve patients had laparoscopic sleeve gastrectomy (LSG procedure in our clinic between March 2011 and September 2013. All procedures were performed with a standard operative technique. Only difference for the last 50 patients was to avoid the excessive dissection of posterior gastric wall. The existence of posterior gastric ligament was recorded and different types of posterior gastric ligament was demonstrated. Results: Posterior gastric ligament was observed in all of the cases in different formation types. Three types of ligament; complete, partial and skippy, was demonstrated. 53(47.3% of the patients had skippy, while 41 (36.6% had partial and 18 (16.1% had complete type of posterior gastric ligament. Conclusion: A ligament named as ‘posterior gastric ligament’ and its various forms were defined in the third dimensional plane of stomach. Posterior gastric ligament remains as the only structure in LSG for preventing the mobility and ability of the stomach to rotate. The excessive dissection of the posterior gastric ligament should be avoided to prevent complications such as kinking and volvulus

  16. Feasibility and profitability of chain integration by NCPAK on flower sleeves products in European market

    NARCIS (Netherlands)

    Yan, X.

    2008-01-01

    In this report, the author describes that the EU flower sleeve wholesalers are the chain leader of the flower sleeve supply chain from China to the EU market. Their strategy changes can easily put NCpak, in full name, 'Sun Hing Plastic Bag Company', a Hong Kong enterprise based on Shenzhen City,

  17. Truck Rollover Characterization for Class-8 Tractor-Trailers Utilizing Standard Dual Tires and New-Generation Single Tires

    Energy Technology Data Exchange (ETDEWEB)

    Capps, Gary [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). National Transportation Research Center; Knee, Bill [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). National Transportation Research Center; Franzese, Oscar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). National Transportation Research Center; Pollock, Paul [Dana Corporation, Kalamazoo, MI (United States). Commercial Vehicle Systems Division; Coleman, Daniel [Dana Corporation, Kalamazoo, MI (United States). Commercial Vehicle Systems Division; Janajreh, Ibrahim [Michelin Americas Research and Development Corporation, Greenville, SC (United States); Haas, Steven [Michelin Americas Research and Development Corporation, Greenville, SC (United States); Frey, Norm [Michelin Americas Research and Development Corporation, Greenville, SC (United States); Law, Harry [Clemson Univ., SC (United States). Fluor Daniel Engineering Innovation Building; Johnson, Eric [Clemson Univ., SC (United States). Fluor Daniel Engineering Innovation Building; Lawson, Robert [Clemson Univ., SC (United States). Fluor Daniel Engineering Innovation Building; Petrolino, Joe [National Transportation Research Center, Inc., Knoxville, TN (United States); Rice, Dave [National Transportation Research Center, Inc., Knoxville, TN (United States)

    2005-07-30

    The Heavy Truck Rollover Characterization Project is a major research effort conducted by the National Transportation Research Center, Inc. (NTRCI) in partnership with Oak Ridge National Laboratory (ORNL), Dana Corporation (Dana), Michelin Americas Research and Development Corporation (Michelin) and Clemson University (Clemson), under the NTRCIs Heavy Vehicle Safety Research Center (HVSRC) for the Federal Highway Administration (FHWA). ORNL provided the day-to-day management of the project. The expertise mix of this team coupled with complementary research needs and interests, and a positive can-do attitude provided an extremely positive experimental research opportunity for all involved. Furthermore, this team supplied significant and valuable resources that provided a strong positive benchmark regarding the ability to conduct research within a public-private partnership. The work conducted by this team focused on initial efforts to generate data and information on heavy truck rollover not currently available in the industry. It reflects efforts within Phases 1 and 2 of a longer-term four-phase research program. A 1999 Peterbilt 379 class-8 tractor and 2004 Wabash dry freight van trailer were the test vehicles utilized in this effort. Both were instrumented with a number of sensors to capture the dynamics of the tractor and trailer as it engaged in various testing maneuvers that included: an evasive maneuver, swept sine, constant radius, and a run-off-the-road maneuver. The run-off-the-road maneuver was discontinued because the test track could not safety accommodate such a maneuver. These maneuvers were carried out utilizing both standard dual tires and new-generation dual tires in six test series. Two test series also included the use of a wider-slider suspension. Outriggers were placed on the test vehicle to assure that an actual rollover would not occur, however, the tests were designed to generate lift-off of tires during the tests. One of the main objectives

  18. Effects of wearing lower leg compression sleeves on locomotion economy.

    Science.gov (United States)

    Kurz, Eduard; Anders, Christoph

    2018-09-01

    The purpose of this investigation was to assess the effect of compression sleeves on muscle activation cost during locomotion. Twenty-two recreationally active men (age: 25 ± 3 years) ran on a treadmill at four different speeds (ordered sequence of 2.8, 3.3, 2.2, and 3.9 m/s). The tests were performed without (control situation, CON) and while wearing specially designed lower leg compression sleeves (SL). Myoelectric activity of five lower leg muscles (tibialis anterior, fibularis longus, lateral and medial head of gastrocnemius, and soleus) was captured using Surface EMG. To assess muscle activation cost, the cumulative muscle activity per distance travelled (CMAPD) of the CON and SL situations was determined. Repeated measures analyses of variance were performed separately for each muscle. The analyses revealed a reduced lower leg muscle activation cost with respect to test situation for SL for all muscles (p  0.18). The respective significant reductions of CMAPD values during SL ranged between 4% and 16% and were largest at 2.8 m/s. The findings presented point towards an improved muscle activation cost while wearing lower leg compression sleeves during locomotion that have potential to postpone muscle fatigue.

  19. Laparoscopic Sleeve Gastrectomy versus Laparoscopic Banded Sleeve Gastrectomy: First Prospective Pilot Randomized Study

    Directory of Open Access Journals (Sweden)

    Valeria Tognoni

    2016-01-01

    Full Text Available Introduction. The placement of ring or band around the gastric tube might prevent the dilation after Laparoscopic Sleeve Gastrectomy (LSG. We describe the first randomized study comparing LSG and Laparoscopic Banded Sleeve Gastrectomy (LBSG. Material and Method. Fifty obese patients were enrolled in the study between January 2014 and January 2015. We analysed differences in operative time, complication rate, mortality, and BMI between the two groups over a period of 12 months. Results. Twenty-five patients received LSG (group A and 25 LBSG (group B. The mean preoperative BMI was 47.3±6.58 kg/m2 and 44.95±5.85 kg/m2, respectively, in the two groups. There was no statistical relevant difference in operative time. No intraoperative complications occurred. Mean BMI registered after 3, 6, and 12 months in groups A and B, respectively, were 37.86±5.72 kg/m2 and 37.58±6.21 kg/m2 (p=0.869, 33.64±6.08 kg/m2 and 32.03±5.24 kg/m2 (p=0.325, and 29.72±4.40 kg/m2 and 27.42±4.47 kg/m2 (p=0.186; no statistical relevant difference was registered between the two groups. Conclusion. LBSG is a safe and feasible procedure. The time required for the device positioning did not influence significantly the surgical time. The results of bodyweight loss did not document any statistically significant differences among the two groups, even though LBSG group showed a mean BMI slightly lower than that of the control group.

  20. Influence of Elastic Bandage and Neoprene Sleeve on Knee Position Sense and Pain in Subjects with Knee Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Basir Majdoleslami

    2003-12-01

    Full Text Available Objective: to investigate whether a neoprene sleeve and elastic bandage around the knee joint of subjects with knee osteoarthritis (OA would , in short term (a reduce pain (b improve knee joint position sense and comparison of their effect with each other if they have. Materials & Methods: In a semi-experimental study, 30 subjects (11 men, 19 women, age between 33-75 with unilateral knee OA. Subjects had to have at least 2cm from 10cm visual analogue scale (VAS of knee pain for study entry.All patients were randomly assigned to either an elastic bandage or a neoprene sleeve. One week later they were assigned to the opposite selection. Joint position sense was assessed in the sitting position using an electrogoniometer and pain by VAS where 0cm equals no pain and 10 cm equals worst pain. Knee pain and JPS were assessed for each selection one week apart. During each visit assessment were performed at baseline and after 20 min of bandage/neoprene sleeve application. Results: the mean of scores for knee variables JPS and VAS was taken and paired-t test and Wilcoxon signed rank test was employed to calculate the different between two trails. Neoprene sleeve had significant effect on knee JPS (P=0.037. But elastic bandage had no effect (P=0.631. Both of them had significantly reduced knee pain. (P=0.000 Conclusion: In subjects with both neoprene sleeve and elastic bandage reduced knee pain with more effect of neoprene sleeve. Only the neoprene sleeve had effect on knee JPS.

  1. A Delphi Consensus of the Crucial Steps in Gastric Bypass and Sleeve Gastrectomy Procedures in the Netherlands.

    Science.gov (United States)

    Kaijser, Mirjam A; van Ramshorst, Gabrielle H; Emous, Marloes; Veeger, Nic J G M; van Wagensveld, Bart A; Pierie, Jean-Pierre E N

    2018-04-09

    Bariatric procedures are technically complex and skill demanding. In order to standardize the procedures for research and training, a Delphi analysis was performed to reach consensus on the practice of the laparoscopic gastric bypass and sleeve gastrectomy in the Netherlands. After a pre-round identifying all possible steps from literature and expert opinion within our study group, questionnaires were send to 68 registered Dutch bariatric surgeons, with 73 steps for bypass surgery and 51 steps for sleeve gastrectomy. Statistical analysis was performed to identify steps with and without consensus. This process was repeated to reach consensus of all necessary steps. Thirty-eight participants (56%) responded in the first round and 32 participants (47%) in the second round. After the first Delphi round, 19 steps for gastric bypass (26%) and 14 for sleeve gastrectomy (27%) gained full consensus. After the second round, an additional amount of 10 and 12 sub-steps was confirmed as key steps, respectively. Thirteen steps in the gastric bypass and seven in the gastric sleeve were deemed advisable. Our expert panel showed a high level of consensus expressed in a Cronbach's alpha of 0.82 for the gastric bypass and 0.87 for the sleeve gastrectomy. The Delphi consensus defined 29 steps for gastric bypass and 26 for sleeve gastrectomy as being crucial for correct performance of these procedures to the standards of our expert panel. These results offer a clear framework for the technical execution of these procedures.

  2. Management of Distal Gastric Leak After Laparoscopic Sleeve Gastrectomy by Double Pigtail Catheter

    Directory of Open Access Journals (Sweden)

    Mani Habibi

    2016-07-01

    Full Text Available Gastric leakage postsurgery is the most feared complication of laparoscopic sleeve gastrectomy due to the difficulty of its management. While gastric leakagemanagement postsurgery is often performed using internal drainage catheters accompanied by self-expandable metal stents, endoscopic internal drainage by double pigtail catheter has recently become a recommended approach. Here we describe our treatment of a patient who experienced distal gastric leakage after undergoing laparoscopic sleeve gastrectomy using double pigtail catheter and our treatment recommendations based on the patient outcome.

  3. Is a sleeve lobectomy significantly better than a pneumonectomy?

    Science.gov (United States)

    Stallard, Joseph; Loberg, Anna; Dunning, Joel; Dark, John

    2010-11-01

    A best evidence topic was written according to a structured protocol. The question addressed was 'whether a sleeve lobectomy results in a better survival rate than a pneumonectomy in suitable patients?' Altogether, more than 327 papers were found using the reported search, of which 15 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. We conclude in the biggest meta-analysis of nearly 3000 patients, the five-year survival was 50% for sleeve lobectomy compared to 30% for pneumonectomy. Operative mortality was 3% vs. 6% for pneumonectomy, and locoregional recurrence was 17% vs. 30%. These results are broadly consistent across all the 13 cohort studies presented here many of which document a 20-year single centre experience or more. There are significant issues in all cohort studies on this subject as, due to their non-randomized nature, the reason for not performing a sleeve resection may well have been more advanced disease, which would necessarily mean that the pneumonectomy patients would have a lower expected survival and higher local recurrence. In addition, there have been many large cohort studies to date and thus no more are required, as future studies are unlikely to resolve this issue. Thus, the only study that would adequately correct for this issue would be a randomized trial, but to prove a 10% increase in five-year survival a 300 patient study would be needed. This is bigger than any study ever done in this area and as some centres took 30 years to collect these numbers of potential sleeve patients an RCT is not a realistic possibility. Therefore, we conclude that no more cohort studies should be performed, as the results will be consistent with the meta-analyses and an RCT to eliminate their bias is unattainable, and thus no more research should be done on this topic and surgeons should use

  4. Heat Generation and Efficiency of a New Modified Phaco Tip and Sleeve.

    Directory of Open Access Journals (Sweden)

    Aeri Yoo

    Full Text Available To compare a modified phacoemulsification tip with the established micro tip, in terms of temperature at the corneal wound, efficiency, and chatter events, using the Centurion® Vision system.Eighty porcine eyes were randomized into 4 groups: 1sleeveless conventional 45D MiniFlared ABS® Kelman tip (1.1-mm incision; 2sleeveless new modified 45D ABS® INTREPID® balanced tip(1.1-mm incision; 3 Kelman tip with own sleeve (2.2-mm incision; 4Balanced tip with modified 4-rib sleeve (2.2-mm incision. Measurements were taken with 2 settings: longitudinal(power 40% and 70% and torsional mode (power 40% and 100%. Peak temperatures were measured 0, 10, 30, and 60 seconds after continuous ultrasound power. For the efficiency test, porcine lens nuclei were formalin soaked and cut into 2.0 mm3 cubes. Efficiency and chatter were examined.In all longitudinal settings, the sleeveless groups(1 and 2 showed lower temperatures than the sleeved groups(3 and 4 (P = 0.003. In 100% torsional mode, groups 3 and 4 produced significantly different temperatures(37.13 ± 1.44 and 35.14 ± 0.54, respectively; P = 0.007.The efficiency, in a 100% power torsional setting, was13.52 ± 2.60 sec for group 4, and 44.45± 14.75 sec for group 3 (P<0.001.The two different bare tips show no significant differences in thermogenesis. However, the balanced tip with sleeve produces lower temperaturesat100% torsional power and better efficiency than the Kelman tip.

  5. Wearing long sleeves while prepping a patient in the operating room decreases airborne contaminants.

    Science.gov (United States)

    Markel, Troy A; Gormley, Thomas; Greeley, Damon; Ostojic, John; Wagner, Jennifer

    2018-04-01

    The use of long sleeves by nonscrubbed personnel in the operating room has been called into question. We hypothesized that wearing long sleeves and gloves, compared with having bare arms without gloves, while applying the skin preparation solution would decrease particulate and microbial contamination. A mock patient skin prep was performed in 3 different operating rooms. A long-sleeved gown and gloves, or bare arms, were used to perform the procedure. Particle counters were used to assess airborne particulate contamination, and active and passive microbial assessment was achieved through air samplers and settle plate analysis. Data were compared with Student's t-test or Mann-Whitney U, and P airborne contamination while the skin prep is applied, which may lead to decreased surgical site infections. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  6. Clinical practice guidelines for rest orthosis, knee sleeves, and unloading knee braces in knee osteoarthritis.

    Science.gov (United States)

    Beaudreuil, Johann; Bendaya, Samy; Faucher, Marc; Coudeyre, Emmanuel; Ribinik, Patricia; Revel, Michel; Rannou, François

    2009-12-01

    To develop clinical practice guidelines concerning the use of bracing--rest orthosis, knee sleeves and unloading knee braces--for knee osteoarthritis. The French Physical Medicine and Rehabilitation Society (SOFMER) methodology, associating a systematic literature review, collection of everyday clinical practice, and external review by multidisciplinary expert panel, was used. Few high-level studies of bracing for knee osteoarthritis were found. No evidence exists for the effectiveness of rest orthosis. Evidence for knee sleeves suggests that they decrease pain in knee osteoarthritis, and their use is associated with subjective improvement. These actions do not appear to depend on a local thermal effect. The effectiveness of knee sleeves for disability is not demonstrated for knee osteoarthritis. Short- and mid-term follow-up indicates that valgus knee bracing decreases pain and disability in medial knee osteoarthritis, appears to be more effective than knee sleeves, and improves quality of life, knee proprioception, quadriceps strength, and gait symmetry, and decreases compressive loads in the medial femoro-tibial compartment. However, results of response to valgus knee bracing remain inconsistent; discomfort and side effects can result. Thrombophlebitis of the lower limbs has been reported with the braces. Braces, whatever kind, are infrequently prescribed in clinical practice for osteoarthritis of the lower limbs. Modest evidence exists for the effectiveness of bracing--rest orthosis, knee sleeves and unloading knee braces--for knee osteoarthritis, with only low level recommendations for its use. Braces are prescribed infrequently in French clinical practice for osteoarthritis of the knee. Randomized clinical trials concerning bracing in knee osteoarthritis are still necessary.

  7. Sleeving-back of horizontal wells to control downstream oil saturation and improve oil recovery

    Energy Technology Data Exchange (ETDEWEB)

    Greaves, M.; Saghr, A. M. [Bath Univ (United Kingdom)

    1998-12-31

    Air injection has become popular as an enhanced recovery technology, applicable over a wide variety of reservoir conditions including heavy, medium and light oils. One problem observed in light oil reservoirs is the tendency to desaturate the oil layer downstream of the moving front. This is particularly common in the case of thermal recovery processes. In this experiment designed to study ways to restrict the de-saturation of the oil layer, a modified horizontal producer well, incorporating a `sleeve-back` principal was used. The objective was to replicate the `toe-to-heel` displacement process occurring during heavy oil recovery, wherein downstream oil is essentially immobile due to its high viscosity. The `sleeve-back` of the well was achieved using a co-aligned, two-well assembly, so that the upstream section of the horizontal producer well was active, and continuously adjusted during propagation of the combustion front. The use of this continuous `sleeve-back` operation to control the level of de-saturation in the downstream section of a sand pack was successful as confirmed by the very high oil recovery achieved, equivalent to 93.5 per cent of oil in place. The level of CO{sub 2} production was also very high. The `sleeve-back` of the horizontal producer well made the light oil in-situ combustion more efficient compared to what would be expected in a fully-open well. The `sleeve-back` of the well also produced thermal contours in the sand pack that closely resembled those observed with heavy, highly viscous oil. By sealing-off the otherwise open well in the downstream part of the reservoir, the de-saturation of the oil layer was prevented. 9 refs., 4 tabs., 9 figs.

  8. Wear Resistance of Piston Sleeve Made of Layered Material Structure: MMC A356R, Anti-Abrasion Layer and FGM Interface

    Directory of Open Access Journals (Sweden)

    Hernik Szymon

    2016-09-01

    Full Text Available The aim of this paper is the numerical analysis of the one of main part of car engine – piston sleeve. The first example is for piston sleeve made of metal matrix composite (MMC A356R. The second improved material structure is layered. Both of them are comparison to the classical structure of piston sleeve made of Cr-Ni stainless steel. The layered material structure contains the anti-abrasion layer at the inner surface of piston sleeve, where the contact and friction is highest, FGM (functionally graded material interface and the layer of virgin material on the outer surface made of A356R. The complex thermo-elastic model with Archard's condition as a wear law is proposed. The piston sleeve is modelling as a thin walled cylindrical axisymmetric shell. The coupled between the formulation of thermo-elasticity of cylindrical axisymmetric shell and the Archard’s law with functionally changes of local hardness is proposed.

  9. Storage envelopes or sleeves

    International Nuclear Information System (INIS)

    Freshwater, J.R.; Wagman, P.I.

    1980-01-01

    A storage envelope or sleeve particularly for processed X-ray films is described. It consists of front and back panels joined together at a hinge line and connected along the intermediate sides by connecting flaps. An inner pocket is formed from a third flap which is folded to lie against the inner face of the back panel. The panels may have additional score lines parallel to the closed sides of the envelope and the inner pocket so that the envelope and the inner pocket can accommodate bulky contents. The free edge of the pocket is inset from the open side of the envelope, and finger cut-outs may be provided to facilitate access to the contents of the envelope and the pocket. (author)

  10. Food Tolerance and Quality of Alimentation Following Laparoscopic Sleeve Gastrectomy Calibrated with a 50-Fr Bougie: Long-Term Results.

    Science.gov (United States)

    Ruiz-Tovar, Jaime; Bozhychko, Maryana; Del-Campo, Jone Miren; Zubiaga, Lorea; Llavero, Carolina

    2018-04-02

    Adjustable gastric banding and vertical banded gastroplasty are associated with the worst postoperative food tolerance of all bariatric techniques. However, food tolerance tends to improve over time. The aim of this study was to assess food tolerance and diet quality in patients undergoing a sleeve gastrectomy, 1 and 5 years after surgery. A prospective observational study of all the morbidly obese patients undergoing laparoscopic sleeve gastrectomy was performed. Food tolerance was assessed using the Quality of Alimentation questionnaire validated in bariatric patients. Ninety-three patients were analyzed. One year after surgery, mean excess weight loss (EWL) was 81.1% ± 8.3%, and 5 years after surgery, mean EWL was 79.9% ± 6.4%. Preoperatively, 39.8% of patients perceived their eating patterns as good or excellent, 1 year after surgery, 79.6% and 5 years postoperatively, 86%. One year after surgery, the patients reported some difficulty in tolerance of rice, pasta, and red meat. Five years after surgery, these difficulties disappeared and very few patients just refer some tolerance difficulties with red meat. One year after surgery, 10% of the patients reported that they suffered postprandial vomiting often and 22% rarely. Five years postoperatively, only 8% of subjects describe rarely vomiting. After sleeve gastrectomy, the patients recognize an improvement in the quality of alimentation. During the first postoperative year, they present tolerance problems with rice, pasta, and red meat, and that disappeared 5 years after surgery.

  11. Perioperative complications of sleeve gastrectomy: Review of the literature.

    Science.gov (United States)

    Iannelli, Antonio; Treacy, Patrick; Sebastianelli, Lionel; Schiavo, Luigi; Martini, Francesco

    2018-05-04

    Sleeve gastrectomy (SG) has known a spectacular rise worldwide during the last decade. The absence of digestive anastomosis simplifies the surgical technique, reducing anastomosis-related complications such as fistula, stricture and marginal ulcer. Furthermore, the respect for digestive continuity preserves the functions of pylorus, that regulates gastric emptying, and duodenum, where calcium, B vitamins and iron are absorbed. Despite the multiple advantages, SG also has specific complications such as bleeding, stenosis, portal thrombosis and leak. The staple line leak at the oesophagogastric junction is the most feared complication and its prevention remains difficult, as the involved mechanisms have been only partially elucidated. Its management is long and requires a multidisciplinary technical platform including Intensive Care Unit, digestive endoscopy and interventional radiology as well as a specialised surgeon. The aim of this review is to explain in detail the perioperative complications of SG, their prevention and treatment, referring to the most recent available literature.

  12. Hemodynamic effect and safety of intermittent sequential pneumatic compression leg sleeves in patients with congestive heart failure.

    Science.gov (United States)

    Bickel, Amitai; Shturman, Alexander; Sergeiev, Michael; Ivry, Shimon; Eitan, Arieh; Atar, Shaul

    2014-10-01

    Pneumatic leg sleeves are widely used after prolonged operations for prevention of venous stasis. In healthy volunteers they increase cardiac function. We evaluated the hemodynamic effects and safety of intermittent sequential pneumatic compression (ISPC) leg sleeves in patients with chronic congestive heart failure (CHF). We studied 19 patients with systolic left ventricular dysfunction and CHF. ISPC leg sleeves, each with 10 air cells, were operated by a computerized compressor, exerting 2 cycles/min. Hemodynamic and echocardiographic parameters were measured before, during, and after ISPC activation. The baseline mean left ventricular ejection fraction was 29 ± 9.2%, median 32%, range 10%-40%. Cardiac output (from 4.26 to 4.83 L/min; P = .008) and stroke volume (from 56.1 to 63.5 mL; P = .029) increased significantly after ISPC activation, without a reciprocal increase in heart rate, and declined after sleeve deactivation. Systemic vascular resistance (SVR) decreased significantly (from 1,520 to 1,216 dyne-s/cm5; P = .0005), and remained lower than the baseline level throughout the study. There was no detrimental effect on diastolic function and no adverse clinical events, despite increased pulmonary venous return. ISPC leg sleeves in patients with chronic CHF do not exacerbate symptoms and transiently improve cardiac output through an increase in stroke volume and a reduction in SVR. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Endoscopic Treatment of Early Gastric Obstruction After Sleeve Gastrectomy: Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Mariana Nuno Costa

    2016-01-01

    Full Text Available Morbid obesity is an epidemic and complex disease which imposes a multidisciplinary approach. Laparoscopic sleeve gastrectomy has become a frequent procedure given its efficacy and safety compared to other surgical options. However, it isn’t free from complications. Lax gastric fixation or incorrect positioning of the stomach during surgery can result in early gastric outlet obstruction caused by a volvulus-like mechanism by rotation of the stomach around its anatomic axes. This report refers to two cases of post sleeve gastric torsion resulting in persisting vomiting after initiating oral intake. The diagnosis was confirmed by upper gastrointestinal-contrast study and gastroscopy. In both cases, a fully covered self-expandable metallic stent was inserted which prompted the gastric lumen to become permeable resulting in symptomatic resolution. The stents were removed endoscopically after two and three months. Beyond more than three years of follow-up, the patients remain asymptomatic and no recurring “stenosis” was noticed. In these cases the use of fully covered self-expandable metallic stents demonstrated to be effective and safe in the treatment of post sleeve gastric torsion.

  14. Axle-sleeve Structured MWCNTs/Polyaniline Composite Film as Cost-effective Counter-Electrodes for High Efficient Dye-Sensitized Solar Cells

    International Nuclear Information System (INIS)

    Niu, Haihong; Qin, Shengxian; Mao, Xiaoli; Zhang, Shouwei; Wang, Renbao; Wan, Lei; Xu, Jinzhang; Miao, Shiding

    2014-01-01

    Graphical abstract: Axle-sleeve structured composite materials made with carbon nanotubes and polyaniline were prepared via a co-polymerization strategy. The composite materials were employed as cost-effective counter electrode modifier in dye-sensitized solar cells which demonstrate a comparable photo-to-electron conversion efficiency as the Pt catalyst. - Highlights: • Axle-sleeve structured MWCNT/PANI composite was prepared. • The optimum mass ratio of MWCNT/ANIranges between 1:3 and 1:1. • The π-π drive force was confirmed by spectroscopicmeans. • The polymerization time of 12∼24 hrs affords the highest conversion efficiency. • The DSSCs assembled with the MWCNTs/PANI CEs exhibit a comparable η(7.21%) as that with Pt CE (7.59%). - Abstract: Axle-sleeve structured composite materials made with multi-walled carbon nanotubes (MWCNTs) and polyaniline (PANI) were prepared, characterized, and employed as cost-effective counter electrodes (CEs) in dye-sensitized solar cells (DSSCs). The composite was synthesized by co-polymerization of aniline with carboxylated MWCNTs by using ammonium persulfate in the acidic medium. Thin films of MWCNTs/PANI were prepared via a spin coating technique followed by thermal treatment in N 2 atmosphere. The micro-structure of the composite was studied by scanning electron microscopy (SEM) and transmission electron microscopy (TEM) linked with energy dispersive spectroscopy (EDS). The coating layer of PANI on the MWCNTs and new-formed chemical bonds between MWCNTs and PANI was studied by UV-Vis absorption, X-ray photoelectron spectroscopy (XPS), Raman and FT-IR spectroscopic means. The effect of the multiple-level porosity or the axle-sleeve structures in the composite of MWCNTs/PANI on the electro-catalytic activity was investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopic (EIS) analysis. The DSSCs assembled with MWCNTs/PANI as CEs exhibit a comparable energy conversion efficiency (η) of 7

  15. Duodenal-jejunal bypass sleeve - a potential alternative to bariatric surgery?

    DEFF Research Database (Denmark)

    Rohde, Ulrich; Gylvin, Silas; Vilmann, Peter

    2014-01-01

    Overweight and obesity are risk factors for several co-morbidities reducing life expectancy. Conservative treatment of obesity is generally ineffective in the long-term. Bariatric surgery has proven effective, but is associated with potential complications. Duodenal-jejunal bypass sleeve is a novel...

  16. Association between postprandial symptoms and gastric emptying after sleeve gastrectomy

    NARCIS (Netherlands)

    Burgerhart, Jan S.; van Rutte, Pim W. J.; Edelbroek, Michela A. L.; Wyndaele, Dirk N. J.; Smulders, Johannes F.; van de Meeberg, Paul C.; Siersema, Peter D.; Smout, André J. P. M.

    2015-01-01

    Laparoscopic sleeve gastrectomy (LSG) is an effective bariatric procedure. However, postprandial symptoms can compromise its beneficial effect. It is not known if a changed gastric emptying and these symptoms are related. This study aimed to assess the association between postprandial symptoms and

  17. Comparison of the key mechanisms leading to rollovers in Liquefied Natural Gas using Computational Fluid Dynamics

    Science.gov (United States)

    Hubert, Antoine; Dadonau, Maksim; Dembele, Siaka; Denissenko, Petr; Wen, Jennifer

    2017-11-01

    Growing demand for the LNG fosters growth of the number of production sites with varying composition and density. Combining different sources of LNG may result in a stably stratified system, in which heat and mass transfer between the layers is limited. Heating of the LNG due to wall thermal conductivity leads to formation of convection cells confined within the layers. While the upper layer can release the extra energy via preferential methane boil-off, the bottom layer cannot and hence becomes superheated. Gradual density equilibration reduces stratification and may eventually lead to a sudden mixing event called ``rollover'', accompanied by violent evaporation of the superheated LNG. Three phenomena are potentially responsible for density equilibration. The first is the growing difference in thermal expansion of the layers due to the reduced ability of the bottom layer to reject heat. The second is the penetration of the heated near-wall boundary layer into the upper layer. The third is the ``entrainment mixing'' occurring at the contact surface between the two layers. The present study uses CFD to compare these mechanisms. Boussinesq approximation and an extended version of the k- ɛ model is used. The code is validated by comparison with a large-scale LNG rollover experiment.

  18. Anticorrosive field joint coating qualification, heat shrinkable sleeve; Qualificacao de revestimento anticorrosivo para juntas de campo, mantas termocontrateis

    Energy Technology Data Exchange (ETDEWEB)

    Cabral, Glaucia B.; Koebsch, Andre; Castinheiras Junior, Wilson [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2005-07-01

    The main objective of this job is to present the quality requirements fixed by PETROBRAS for anticorrosive field joint coating for buried pipelines, industrially coated with PE-3L. It describes the used system - polyethylene based heat shrinkable sleeve - comparing with the existent on the pipeline. So, it exposes the suppliers' qualification stages, which include test carried out for the materials, for the sleeve set and for the coating after its application on the joint field. Finally, it shows that the experience, which has been gotten in the qualification, consolidated the quality control systematic that have been carry out during the sleeves acquisition and application at the pipeline construction. (author)

  19. Laparoscopic hand-assisted versus robotic-assisted laparoscopic sleeve gastrectomy: experience of 103 consecutive cases.

    Science.gov (United States)

    Kannan, Umashankkar; Ecker, Brett L; Choudhury, Rashikh; Dempsey, Daniel T; Williams, Noel N; Dumon, Kristoffel R

    2016-01-01

    Laparoscopic sleeve gastrectomy has become a stand-alone procedure in the treatment of morbid obesity. There are very few reports on the use of robotic approach in sleeve gastrectomy. The purpose of this retrospective study is to report our early experience of robotic-assisted laparoscopic sleeve gastrectomy (RALSG) using a proctored training model with comparison to an institutional cohort of patients who underwent laparoscopic hand-assisted sleeve gastrectomy (LASG). University hospital. The study included 108 patients who underwent sleeve gastrectomy either via the laparoscopic-assisted or robot-assisted approach during the study period. Of these 108 patients, 62 underwent LASG and 46 underwent RALSG. The console surgeon in the RALSG is a clinical year 4 (CY4) surgery resident. All CY4 surgery residents received targeted simulation training before their rotation. The console surgeon is proctored by the primary surgeon with assistance as needed by the second surgeon. The patients in the robotic and laparoscopic cohorts did not have a statistical difference in their demographic characteristics, preoperative co-morbidities, or complications. The mean operating time did not differ significantly between the 2 cohorts (121 min versus 110 min, P = .07). Patient follow-up in the LSG and RALSG were 91% and 90% at 3 months, 62% and 64% at 6 months, and 60% and 55% at 1 year, respectively. The mean percentage estimated weight loss (EWL%) at 3 months, 6 months, and 1 year was greater in the robotic group but not statistically significant (27 versus 22 at 3 mo [P = .05] and 39 versus 34 at 6 mo [P = .025], 57 versus 48 at 1 yr [P = .09]). There was no mortality in either group. Early results of our experience with RALSG indicate low perioperative complication rates and comparable weight loss with LASG. The concept of a stepwise education model needs further validation with larger studies. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc

  20. A Wideband Dual-Polarized Antenna Using Planar Quasi-Open-Sleeve Dipoles for Base Station Applications

    Directory of Open Access Journals (Sweden)

    Guan-xi Zhang

    2015-01-01

    Full Text Available A wideband dual-polarized antenna for WLAN, WiMAX, and LTE base station applications is presented in this paper. The proposed antenna consists of two pairs of orthogonal planar quasi-open-sleeve dipoles along the centerlines, a balanced feeding structure and a square ground plane. The planar quasi-open-sleeve dipole comprises a pair of bowtie-shaped planar dipoles with two parallel curve parasitic elements. The introduced parallel curve parasitic elements change the path of the current of the original bowtie-shaped planar dipoles at high frequencies and hence wideband characteristic is achieved. Two pairs of the planar quasi-open-sleeve dipoles placed orthogonally further broaden the bandwidth of the antenna with dual-polarization characteristics. The proposed antenna achieves a 10-dB return loss bandwidth from 2.32 to 4.03 GHz (53.9% bandwidth using the planar quasi-open-sleeve dipole structures. The isolation between the two ports remains more than 32 dB in the whole bandwidth. Measured results show that the proposed antenna keeps the cross-polarization under −33 dB and the front-to-back ratio better than 15 dB in the operating band. The antenna has an area of 0.3λ  × 0.3λ at 2.32 GHz making it easy to be extended to an array element.

  1. Double-Acting Sleeve Muscle Actuator for Bio-Robotic Systems

    Directory of Open Access Journals (Sweden)

    Hao Zheng

    2013-11-01

    Full Text Available This paper presents a new type of muscle-like actuator, namely double-acting (DA sleeve muscle actuator, which is suitable for the actuation of biologically-inspired and biomedical robotic systems, especially those serving human-assistance purposes (prostheses, orthoses, etc.. Developed based on the traditional pneumatic muscle actuator, the new DA sleeve muscle incorporates a unique insert at the center. With the insert occupying the central portion of the internal volume, this new actuator enjoys multiple advantages relative to the traditional pneumatic muscle, including a consistent increase of force capacity over the entire range of motion, and a significant decrease of energy consumption in operation. Furthermore, the insert encompasses an additional chamber, which generates an extension force when pressurized. As such, this new actuator provides a unique bi-directional actuation capability, and, thus, has a potential to significantly simplify the design of a muscle actuator-powered robotic system. To demonstrate this new actuator concept, a prototype has been designed and fabricated, and experiments conducted on this prototype demonstrated the enhanced force capacity and the unique bi-directional actuation capability.

  2. Double-Acting Sleeve Muscle Actuator for Bio-Robotic Systems

    Science.gov (United States)

    Zheng, Hao; Shen, Xiangrong

    2014-01-01

    This paper presents a new type of muscle-like actuator, namely double-acting (DA) sleeve muscle actuator, which is suitable for the actuation of biologically-inspired and biomedical robotic systems, especially those serving human-assistance purposes (prostheses, orthoses, etc.). Developed based on the traditional pneumatic muscle actuator, the new DA sleeve muscle incorporates a unique insert at the center. With the insert occupying the central portion of the internal volume, this new actuator enjoys multiple advantages relative to the traditional pneumatic muscle, including a consistent increase of force capacity over the entire range of motion, and a significant decrease of energy consumption in operation. Furthermore, the insert encompasses an additional chamber, which generates an extension force when pressurized. As such, this new actuator provides a unique bi-directional actuation capability, and, thus, has a potential to significantly simplify the design of a muscle actuator-powered robotic system. To demonstrate this new actuator concept, a prototype has been designed and fabricated, and experiments conducted on this prototype demonstrated the enhanced force capacity and the unique bi-directional actuation capability. PMID:25264492

  3. Double-Acting Sleeve Muscle Actuator for Bio-Robotic Systems.

    Science.gov (United States)

    Zheng, Hao; Shen, Xiangrong

    2013-11-25

    This paper presents a new type of muscle-like actuator, namely double-acting (DA) sleeve muscle actuator, which is suitable for the actuation of biologically-inspired and biomedical robotic systems, especially those serving human-assistance purposes (prostheses, orthoses, etc .). Developed based on the traditional pneumatic muscle actuator, the new DA sleeve muscle incorporates a unique insert at the center. With the insert occupying the central portion of the internal volume, this new actuator enjoys multiple advantages relative to the traditional pneumatic muscle, including a consistent increase of force capacity over the entire range of motion, and a significant decrease of energy consumption in operation. Furthermore, the insert encompasses an additional chamber, which generates an extension force when pressurized. As such, this new actuator provides a unique bi-directional actuation capability, and, thus, has a potential to significantly simplify the design of a muscle actuator-powered robotic system. To demonstrate this new actuator concept, a prototype has been designed and fabricated, and experiments conducted on this prototype demonstrated the enhanced force capacity and the unique bi-directional actuation capability.

  4. Acute Pancreatitis with Splenic Infarction as Early Postoperative Complication following Laparoscopic Sleeve Gastrectomy

    Directory of Open Access Journals (Sweden)

    Aleksandr Kalabin

    2017-01-01

    Full Text Available Obesity is becoming a global health burden along with its comorbidities. It imposes tremendous financial burden and health costs worldwide. Surgery has emerged as the definitive treatment option for morbidly obese patients with comorbidities. Laparoscopic sleeve gastrectomy is performed now more than ever making it imperative for physicians and surgeons to recognize both the common and the uncommon risks and complications associated with it. In this report we describe a rare early life-threatening postoperative complication following laparoscopic sleeve gastrectomy. From our extensive review of literature, there is no existing report of acute pancreatitis with splenic infarction postsleeve gastrectomy to this date.

  5. Experimental and numerical study of steel pipe with part-wall defect reinforced with fibre glass sleeve

    International Nuclear Information System (INIS)

    Mazurkiewicz, Lukasz; Tomaszewski, Michal; Malachowski, Jerzy; Sybilski, Kamil; Chebakov, Mikhail; Witek, Maciej; Yukhymets, Peter; Dmitrienko, Roman

    2017-01-01

    The paper presents numerical and experimental burst pressure evaluation of the gas seamless hot-rolled steel pipe. The main goal was to estimate mechanical toughness of pipe wrapped with composite sleeve and verify selected sleeve thickness. The authors used a nonlinear explicit FE code with constitutive models which allows for steel and composite structure failure modelling. Thanks to the achieved numerical and analytical results it was possible to perform the comparison with data received from a capacity test and good correlation between the results were obtained. Additionally, the conducted analyses revealed that local reduction of pipe wall thickness from 6 mm to 2.4 mm due to corrosion defect can reduce high pressure resistance by about 40%. Finally, pipe repaired by a fibre glass sleeve with epoxy resin with 6 mm thickness turned out more resistant than an original steel pipe considering burst pressure. - Highlights: • Numerical and experimental burst pressure evaluation of steel pipe was performed. • Seamless hot-rolled steel pipe with and without corrosion defect were considered. • Local reduction of pipe wall thickness from 6 to 2.4 mm reduces resistance by 40%. • Pipe repaired by a 6 mm fibre glass sleeve was more resistant than an original pipe.

  6. A LQR-Based Controller with Estimation of Road Bank for Improving Vehicle Lateral and Rollover Stability via Active Suspension

    Directory of Open Access Journals (Sweden)

    Andres Riofrio

    2017-10-01

    Full Text Available In this article, a Linear Quadratic Regulator (LQR lateral stability and rollover controller has been developed including as the main novelty taking into account the road bank angle and using exclusively active suspension for both lateral stability and rollover control. The main problem regarding the road bank is that it cannot be measured by means of on-board sensors. The solution proposed in this article is performing an estimation of this variable using a Kalman filter. In this way, it is possible to distinguish between the road disturbance component and the vehicle’s roll angle. The controller’s effectiveness has been tested by means of simulations carried out in TruckSim, using an experimentally-validated vehicle model. Lateral load transfer, roll angle, yaw rate and sideslip angle have been analyzed in order to quantify the improvements achieved on the behavior of the vehicle. For that purpose, these variables have been compared with the results obtained from both a vehicle that uses passive suspension and a vehicle using a fuzzy logic controller.

  7. A LQR-Based Controller with Estimation of Road Bank for Improving Vehicle Lateral and Rollover Stability via Active Suspension.

    Science.gov (United States)

    Riofrio, Andres; Sanz, Susana; Boada, Maria Jesus L; Boada, Beatriz L

    2017-10-13

    In this article, a Linear Quadratic Regulator (LQR) lateral stability and rollover controller has been developed including as the main novelty taking into account the road bank angle and using exclusively active suspension for both lateral stability and rollover control. The main problem regarding the road bank is that it cannot be measured by means of on-board sensors. The solution proposed in this article is performing an estimation of this variable using a Kalman filter. In this way, it is possible to distinguish between the road disturbance component and the vehicle's roll angle. The controller's effectiveness has been tested by means of simulations carried out in TruckSim, using an experimentally-validated vehicle model. Lateral load transfer, roll angle, yaw rate and sideslip angle have been analyzed in order to quantify the improvements achieved on the behavior of the vehicle. For that purpose, these variables have been compared with the results obtained from both a vehicle that uses passive suspension and a vehicle using a fuzzy logic controller.

  8. The effective neutron temperature in heated graphite sleeves

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, J A; Small, V G [General Reactor Physics Division, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1963-08-15

    In a series of oscillator measurements carried out in the reactor NERO the variation of the relative reaction rates of cadmium and boron absorbers has been used to determine the effective neutron temperature inside heated graphite sleeves. This work extends the scope of similar oscillator measurements previously carried out in DIMPLE, in that the bulk moderator is now graphite as opposed to D{sub 2}O in the former case. (author)

  9. Endoluminal stenting for the management of leak following sleeve gastrectomy and loop duodenojejunal bypass with sleeve gastrectomy

    Directory of Open Access Journals (Sweden)

    Ying-Nan Tsai

    2018-01-01

    Full Text Available Postoperative leak is a serious complication of bariatric surgery and often results in significant morbidity and mortality. Stent placement is a less invasive alternative to surgery for the treatment of bariatric surgical leak. We evaluated the efficacy and complications of covered self-expandable metal stents (SEMS in the treatment of post-bariatric surgical leak. We retrospectively reviewed patients who underwent stent placement for leak after bariatric surgery. Leak was diagnosed by upper gastrointestinal series or was visualized during the endoscopy. We examined the timing of stent placement, size of the leak, stent migration and its complications, total stent treatment duration, and treatment outcome. Between January 2011 and April 2015, seven patients underwent covered SEMS placement for leak after bariatric surgery, including laparoscopic sleeve gastrectomy (LSG (n = 5 and laparoscopic loop duodenojejunal bypass with sleeve gastrectomy (LDJB-SG (n = 2. A stent was placed in one patient for infection control and bridging to revisional surgery. Among the other six patients, one patient who received stent placement one year after leak diagnosis failed to achieve leak closure, and five patients with early stent placement achieved leak closure. Three patients with small leak achieved leak closure more quickly. Stent migration was found in six patients, and associated ulcers occurred in five patients. We conclude that stenting is effective in the management of staple-line leaks following LSG and LDJB-SG. Stent migration and associated ulcers are common after stent placement. Early stent removal can be achieved in patients with small leaks.

  10. Endoluminal stenting for the management of leak following sleeve gastrectomy and loop duodenojejunal bypass with sleeve gastrectomy.

    Science.gov (United States)

    Tsai, Ying-Nan; Wang, Hsiu-Po; Huang, Chih-Kun; Chang, Po-Chin; Lin, I-Chang; Tai, Chi-Ming

    2018-01-01

    Postoperative leak is a serious complication of bariatric surgery and often results in significant morbidity and mortality. Stent placement is a less invasive alternative to surgery for the treatment of bariatric surgical leak. We evaluated the efficacy and complications of covered self-expandable metal stents (SEMS) in the treatment of post-bariatric surgical leak. We retrospectively reviewed patients who underwent stent placement for leak after bariatric surgery. Leak was diagnosed by upper gastrointestinal series or was visualized during the endoscopy. We examined the timing of stent placement, size of the leak, stent migration and its complications, total stent treatment duration, and treatment outcome. Between January 2011 and April 2015, seven patients underwent covered SEMS placement for leak after bariatric surgery, including laparoscopic sleeve gastrectomy (LSG) (n = 5) and laparoscopic loop duodenojejunal bypass with sleeve gastrectomy (LDJB-SG) (n = 2). A stent was placed in one patient for infection control and bridging to revisional surgery. Among the other six patients, one patient who received stent placement one year after leak diagnosis failed to achieve leak closure, and five patients with early stent placement achieved leak closure. Three patients with small leak achieved leak closure more quickly. Stent migration was found in six patients, and associated ulcers occurred in five patients. We conclude that stenting is effective in the management of staple-line leaks following LSG and LDJB-SG. Stent migration and associated ulcers are common after stent placement. Early stent removal can be achieved in patients with small leaks. Copyright © 2017. Published by Elsevier Taiwan.

  11. Long term (7 or more years) outcomes of the sleeve gastrectomy: a meta-analysis.

    Science.gov (United States)

    Clapp, Benjamin; Wynn, Matthew; Martyn, Colin; Foster, Chase; O'Dell, Montana; Tyroch, Alan

    2018-03-06

    The laparoscopic sleeve gastrectomy is now the most common bariatric operation in the United States and has become an established procedure in the armamentarium of the bariatric surgeon. However, this has happened without the strong support of long-term outcomes data, namely the rate of revision and durability of the weight loss. Newly published data from around the world are starting to show alarming trends in these 2 areas. This paper will examine the published and presented data with at least a 7-year follow-up. This is a meta-analysis on published data with at least 7 years of follow-up from the laparoscopic sleeve gastrectomy. Online published articles. We performed a meta-analysis of publications with at least 7 years of follow-up with the keywords "laparoscopic, bariatric, sleeve gastrectomy, sleeve, long-term, long, term, results, follow-up, follow up, conversion, 7 years, 8 years, 9 years, 10 years, 11 years." We queried the PubMed, MEDLINE, and ClinicalKey search engines, which included abstracts as well. The I 2 statistic was used to determine the heterogeneity across the studies. In presence of heterogeneity, a random effect model using the Dersimonian and Laird method was used to estimate the pooled estimates. The results were summarized using effect size along with a 95% confidence interval (CI). Meta-regression was also used to assess the effect of body mass index and follow-up years on the incidence of recidivism at ≥7 years. Nine cohort studies met the inclusion criteria, with a total of 2280 patients included initially. Only 652 patients had completed ≥7 years of follow-up. At ≥7 years, the long-term weight recidivism rate was estimated to be 27.8% (I 2 = .60%; 95% CI: 22.8%-32.7%) with a range of 14% to 37%. The overall revision rate was estimated to be 19.9% (I 2 = 93.8%; 95% CI: 11.3%-28.5%). This was broken down into 13.1% (I 2 = 93.8%; 95% CI: 5.6%-20.6%) due to weight regain (5 studies) and 2.9% (I 2 = 60.8%; 95% CI: 1%-4.9%) due to

  12. Action Learning: A New Method to Increase Tractor Rollover Protective Structure (ROPS) Adoption

    Science.gov (United States)

    Biddle, Elyce Anne; Keane, Paul R.

    2016-01-01

    Action Learning is a problem-solving process that is used in various industries to address difficult problems. This project applied Action Learning to a leading problem in agricultural safety. Tractor overturns are the leading cause of fatal injury to farmworkers. This cause of injury is preventable using rollover protective structures (ROPS), protective equipment that functions as a roll bar structure to protect the operator in the event of an overturn. For agricultural tractors manufactured after 1976 and employee operated, Occupational Safety and Health Administration (OSHA) regulation requires employers to equip them with ROPS and seat belts. By the mid-1980s, US tractor manufacturers began adding ROPS on all farm tractors over 20 horsepower sold in the United States (http://www.nasdonline.org/document/113/d001656/rollover-protection-for-farm-tractor-operators.html). However, many older tractors remain in use without ROPS, putting tractor operators at continued risk for traumatic injury and fatality. For many older tractor models ROPS are available for retrofit, but for a variety of reasons, tractor owners have not chosen to retrofit those ROPS. The National Institute for Occupational Safety and Health (NIOSH) attempted various means to ameliorate this occupational safety risk, including the manufacture of a low-cost ROPS for self-assembly. Other approaches address barriers to adoption. An Action Learning approach to increasing adoption of ROPS was followed in Virginia and New York, with mixed results. Virginia took action to increase the manufacturing and adoption of ROPS, but New York saw problems that would be insurmountable. Increased focus on team composition might be needed to establish effective Action Learning teams to address this problem. PMID:22994641

  13. Gastroesophageal Reflux Management with the LINX® System for Gastroesophageal Reflux Disease Following Laparoscopic Sleeve Gastrectomy.

    Science.gov (United States)

    Desart, Kenneth; Rossidis, Georgios; Michel, Michael; Lux, Tamara; Ben-David, Kfir

    2015-10-01

    Laparoscopic sleeve gastrectomy (LSG) has gained significant popularity in the USA, and consequently resulted in patients experiencing new-onset gastroesophageal reflux disease (GERD) following this bariatric procedure. Patients with GERD refractory to medical therapy present a more challenging situation limiting the surgical options to further treat the de novo GERD symptoms since the gastric fundus to perform a fundoplication is no longer an option. The aim of this study is to determine if the LINX® magnetic sphincter augmentation system is a safe and effective option for patients with new gastroesophageal reflux disease following laparoscopic sleeve gastrectomy. This study was conducted at the University Medical Center. This is a retrospective review of seven consecutive patients who had a laparoscopic LINX® magnetic sphincter device placement for patients with refractory gastroesophageal reflux disease after laparoscopic sleeve gastrectomy between July 2014 and April 2015. All patients were noted to have self-reported greatly improved gastroesophageal reflux symptoms 2-4 weeks after their procedure. They were all noted to have statistically significant improved severity and frequency of their reflux, regurgitation, epigastric pain, sensation of fullness, dysphagia, and cough symptoms in their postoperative GERD symptoms compared with their preoperative evaluation. This is the first reported pilot case series, illustrating that the LINX® device is a safe and effective option in patients with de novo refractory gastroesophageal reflux disease after a laparoscopic sleeve gastrectomy despite appropriate weight loss.

  14. Changes in the makeup of bariatric surgery: a national increase in use of laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Nguyen, Ninh T; Nguyen, Brian; Gebhart, Alana; Hohmann, Samuel

    2013-02-01

    Laparoscopic sleeve gastrectomy is gaining popularity in the US; however, there has been no study examining the use of sleeve gastrectomy at a national level and its impact on the use of other bariatric operations. The aim of this study was to examine contemporary changes in use and outcomes of bariatric surgery performed at academic medical centers. Using ICD-9 diagnosis and procedure codes, clinical data obtained from the University HealthSystem Consortium database for all bariatric procedures performed for the treatment of morbid obesity between October 1, 2008 and September 30, 2012 were reviewed. Quartile trends in use for the 3 most commonly performed bariatric operations were examined, and a comparison of perioperative outcomes between procedures was performed within a subset of patients with minor severity of illness. A total of 60,738 bariatric procedures were examined. In 2008, the makeup of bariatric surgery consisted primarily of gastric bypass (66.8% laparoscopic, 8.6% open), followed by laparoscopic gastric banding (23.8%). In 2012, there was a precipitous increase in use of laparoscopic sleeve gastrectomy (36.3 %), with a concurrent reduction in the use of laparoscopic (56.4%) and open (3.2%) gastric bypass, and a major reduction in laparoscopic gastric banding (4.1%). The length of hospital stay, in-hospital morbidity and mortality, and costs for laparoscopic sleeve gastrectomy were found to be between those of laparoscopic gastric banding and laparoscopic gastric bypass. Within the context of academic medical centers, there has been a recent change in the makeup of bariatric surgery. There has been an increase in the use of laparoscopic sleeve gastrectomy, which has had an impact primarily on reducing the use of laparoscopic adjustable gastric banding. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Rotor losses in laminated magnets and an anisotropic carbon fiber sleeve

    NARCIS (Netherlands)

    Van der Geest, M.; Wolmarans, J.J.; Polinder, H.; Ferreira, J.A.; Zeilstra, D.

    2012-01-01

    High speed fault tolerant permanent magnet machines have strong asynchronous airgap harmonics, making them susceptible to rotor eddy-current losses. These losses can be reduced by using novel high resistivity materials like plastic bonded magnets and carbon fiber reinforced retaining sleeves. This

  16. Gastritis in patients undergoing sleeve gastrectomy

    Science.gov (United States)

    Rath-Wolfson, Lea; Varona, Roy; Bubis, Golan; Tatarov, Alexander; Koren, Rumelia; Ram, Edward

    2017-01-01

    Abstract Laparoscopic sleeve gastrectomy (LSG) is a therapeutic option in severely obese patients. The aim of this study was to evaluate the presence of Helicobacter pylori (HP) gastritis and non-Helicobacter gastritis in the gastrectomy specimens, and its association to other variables. One hundred six sleeve gastrectomy specimens were examined histopathologically for the presence of gastritis and its relation to other factors like ethnicity, glycemic control, and postoperative complications. Twelve patients had HP gastritis, 39 had non-HP gastritis, and 55 had normal mucosa. There was a statistical difference between the Arab and Jewish Israeli patients in our study. Twenty-eight of the Arab patients had HP gastritis and 48% had non-HP gastritis. In the Jewish population 6% had HP gastritis and 34% had non-HP gastritis. The preoperative glycemic control was worse in the gastritis group with a mean HbA1c of 8.344% while in the normal mucosa group the mean HbA1c was 6.55. After operation the glycemic control reverted to normal in most the diabetic patients. There were few postoperative complications however, they were not related to HP. There is a high incidence of gastritis in obese patients. The incidence of gastritis in the Arab population in our study was higher than that in the Jewish population. The glycemic control before surgery was worse in patients with gastritis than in the normal mucosa group. HP bares no risk for postoperative complications after LSG and does not affect weight loss. However a larger cohort of patients must be studied to arrive at conclusive results. PMID:28422853

  17. The design, effectiveness and acceptability of the arm sleeve for the prevention of body fluid contamination during obstetric procedures.

    Science.gov (United States)

    Kabukoba, J J; Pearce, J M

    1993-08-01

    1. To design a device that would reduce contamination of staff during obstetric procedures. 2. To undertake clinical trials to assess the effectiveness and acceptability of such a device. A prospective study. The arm sleeve is made of a nonwoven material laminated on polyethylene film making it waterproof. It has an elastomeric cuff with adhesive that ensures a watertight seal between it and the glove. Delivery suite in a teaching hospital. Doctors and midwives were requested to wear the sleeve on top of the standard gown and gloves. Each user was assessed for blood contamination at the end of the procedure and a questionnaire detailing the extent of contamination and the views of the user was completed. Eighty questionnaires were completed. The contamination of arms and hands was 3.8% and 5%, respectively. Eighty-nine percent thought the sleeve had served its purpose and 76% said they would use it regularly. The sleeve is an effective protective device which complements the glove and gown. We recommend that it should be used during all obstetric procedures.

  18. Effect of vertical sleeve gastrectomy in melanocortin receptor 4-deficient rats

    NARCIS (Netherlands)

    Mul, J.D.; Begg, D.P.; Alsters, S.I.; van Haaften, G.; Duran, K.J.; D'Alessio, D.A.; le Roux, C.W.; Woods, S.C.; Sandoval, D.A.; Blakemore, A.I.; Cuppen, E.; van Haelst, M.M.; Seeley, R.J.

    2012-01-01

    Bariatric surgery is currently the most effective treatment for obesity. Vertical sleeve gastrectomy (VSG), a commonly applied bariatric procedure, involves surgically incising most of the volume of the stomach. In humans, partial loss of melanocortin receptor-4 (MC4R) activity is the most common

  19. Sleeve resection for delayed presentation of traumatic bronchial transection.

    LENUS (Irish Health Repository)

    Mohamed, H Y

    2010-02-01

    Tracheobronchial disruption is uncommon in blunt chest trauma. Many of these patients die before reaching the hospital. In the majority of survivors diagnosis is occasionally delayed resulting in complications like airway stenosis and lung collapse. Thus it is important to have radiological follow up after severe thoracic trauma. Sleeve resection can be an excellent option to conserve lung tissue in delayed presentation of bronchial transection.

  20. Architecture and permeability of post-cytokinesis plasmodesmata lacking cytoplasmic sleeves.

    Science.gov (United States)

    Nicolas, William J; Grison, Magali S; Trépout, Sylvain; Gaston, Amélia; Fouché, Mathieu; Cordelières, Fabrice P; Oparka, Karl; Tilsner, Jens; Brocard, Lysiane; Bayer, Emmanuelle M

    2017-06-12

    Plasmodesmata are remarkable cellular machines responsible for the controlled exchange of proteins, small RNAs and signalling molecules between cells. They are lined by the plasma membrane (PM), contain a strand of tubular endoplasmic reticulum (ER), and the space between these two membranes is thought to control plasmodesmata permeability. Here, we have reconstructed plasmodesmata three-dimensional (3D) ultrastructure with an unprecedented level of 3D information using electron tomography. We show that within plasmodesmata, ER-PM contact sites undergo substantial remodelling events during cell differentiation. Instead of being open pores, post-cytokinesis plasmodesmata present such intimate ER-PM contact along the entire length of the pores that no intermembrane gap is visible. Later on, during cell expansion, the plasmodesmata pore widens and the two membranes separate, leaving a cytosolic sleeve spanned by tethers whose presence correlates with the appearance of the intermembrane gap. Surprisingly, the post-cytokinesis plasmodesmata allow diffusion of macromolecules despite the apparent lack of an open cytoplasmic sleeve, forcing the reassessment of the mechanisms that control plant cell-cell communication.

  1. Effect of Laparoscopic Sleeve Gastrectomy vs Laparoscopic Roux-en-Y Gastric Bypass on Weight Loss in Patients With Morbid Obesity: The SM-BOSS Randomized Clinical Trial.

    Science.gov (United States)

    Peterli, Ralph; Wölnerhanssen, Bettina Karin; Peters, Thomas; Vetter, Diana; Kröll, Dino; Borbély, Yves; Schultes, Bernd; Beglinger, Christoph; Drewe, Jürgen; Schiesser, Marc; Nett, Philipp; Bueter, Marco

    2018-01-16

    Sleeve gastrectomy is increasingly used in the treatment of morbid obesity, but its long-term outcome vs the standard Roux-en-Y gastric bypass procedure is unknown. To determine whether there are differences between sleeve gastrectomy and Roux-en-Y gastric bypass in terms of weight loss, changes in comorbidities, increase in quality of life, and adverse events. The Swiss Multicenter Bypass or Sleeve Study (SM-BOSS), a 2-group randomized trial, was conducted from January 2007 until November 2011 (last follow-up in March 2017). Of 3971 morbidly obese patients evaluated for bariatric surgery at 4 Swiss bariatric centers, 217 patients were enrolled and randomly assigned to sleeve gastrectomy or Roux-en-Y gastric bypass with a 5-year follow-up period. Patients were randomly assigned to undergo laparoscopic sleeve gastrectomy (n = 107) or laparoscopic Roux-en-Y gastric bypass (n = 110). The primary end point was weight loss, expressed as percentage excess body mass index (BMI) loss. Exploratory end points were changes in comorbidities and adverse events. Among the 217 patients (mean age, 45.5 years; 72% women; mean BMI, 43.9) 205 (94.5%) completed the trial. Excess BMI loss was not significantly different at 5 years: for sleeve gastrectomy, 61.1%, vs Roux-en-Y gastric bypass, 68.3% (absolute difference, -7.18%; 95% CI, -14.30% to -0.06%; P = .22 after adjustment for multiple comparisons). Gastric reflux remission was observed more frequently after Roux-en-Y gastric bypass (60.4%) than after sleeve gastrectomy (25.0%). Gastric reflux worsened (more symptoms or increase in therapy) more often after sleeve gastrectomy (31.8%) than after Roux-en-Y gastric bypass (6.3%). The number of patients with reoperations or interventions was 16/101 (15.8%) after sleeve gastrectomy and 23/104 (22.1%) after Roux-en-Y gastric bypass. Among patients with morbid obesity, there was no significant difference in excess BMI loss between laparoscopic sleeve gastrectomy and laparoscopic Roux

  2. Steam generator thermal sleeve reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Caton, E.; Askari, A.; Volder, P. [Babcock and Wilcox Canada Ltd., Cambridge, Ontario (Canada)]. E-mail: eecaton@babcock.com

    2003-07-01

    'Full text:' Successful implementation of a physically difficult repair program requires collaboration of the design and construction functions of an organization to ensure that goals are shared and rework or on-the-fly design changes are not required. Furthermore, in a nuclear facility this collaboration results in the optimal safety condition as dose uptake is minimized with a well planned job. The replacement of the degraded thermal sleeves in the Pickering A Steam Generator feedwater nozzles posed this type of problem. The project may be summarized as follows: i) problem analysis, ii) identification of design parameters and limitations, iii) integration of field engineering and design engineering solutions, iv) installation. Integration of the design engineering and field engineering design parameters ensured that the most effective solution was implemented. (author)

  3. De novo gastric adenocarcinoma 1 year after sleeve gastrectomy in a transplant patient

    Directory of Open Access Journals (Sweden)

    M. Masrur

    2016-01-01

    Conclusions: No direct relation has been established between sleeve gastrectomy and the development of gastric cancer. Robotic procedures allow for complex multiorgan resections, while preserving the benefits of minimally invasive surgery.

  4. Laparoscopic Gastric Sleeve and Micronutrients Supplementation: Our Experience

    Directory of Open Access Journals (Sweden)

    D. Capoccia

    2012-01-01

    Full Text Available Background. Laparoscopic gastric sleeve (LGS has been recently introduced as a stand-alone, restrictive bariatric surgery. Theoretically, LGS attenuates micronutrients deficiencies and associated complications that were typically observed following malabsorptive procedures. The aim of this study was to assess some micronutrients and mineral deficiencies in patients undergoing LGS. Methods. In the period between July 2008 and April 2010, 138 obese patients (110 females and 28 males with mean BMI 44.4 kg/m2 ± 6.5, mean age 43.9±10.9 years were enrolled and underwent LGS. Patients were followed up with routine laboratory tests and anthropometric measurements and assessed for nutritional status, as regards vitamin B12, folic acid, iron, hemoglobin, calcium, and vitamin D, every three months throughout 12 months. Results. 12 months after sleeve, patients did not show iron deficiency and/or anemia; plasma calcium levels were in the normal range without supplementation from the sixth month after the operation. Vitamin B12 and folic acid were adequately supplemented for all the follow-up period. Vitamin D was in suboptimal levels, despite daily multivitamin supplementation. Conclusion. In this study, we showed that LGS is an effective surgery for the management of morbid obesity. An adequate supplementation is important to avoid micronutrients deficiencies and greater weight loss does not require higher dosage of multivitamins.

  5. [A Method Research on Environmental Damage Assessment of a Truck Rollover Pollution Incident].

    Science.gov (United States)

    Cai, Feng; Zhao, Shi-ho; Chen, Gang-cai; Xian, Si-shu; Yang, Qing-ling; Zhou, Xian-jie; Yu, Hai

    2015-05-01

    With high occurrence of sudden water pollution incident, China faces an increasingly severe situation of water environment. In order to deter the acts of environmental pollution, ensure the damaged resources of environment can be restored and compensated, it is very critical to quantify the economic losses caused by the sudden water pollution incident. This paper took truck rollover pollution incidents in Chongqing for an example, established a set of evaluation method for quantifying the environmental damage, and then assessed the environmental damage by the method from four aspects, including the property damage, ecological environment and resources damages, the costs of administrative affairs in emergency disposal, and the costs of investigation and evaluation.

  6. Composting municipal biosolids in polyethylene sleeves with forced aeration: Process control, air emissions, sanitary and agronomic aspects.

    Science.gov (United States)

    Avidov, R; Saadi, I; Krassnovsky, A; Hanan, A; Medina, Sh; Raviv, M; Chen, Y; Laor, Y

    2017-09-01

    Composting in polyethylene sleeves with forced aeration may minimize odor emissions, vectors attraction and leachates associated with open windrows. A disadvantage of this technology is the lack of mixing during composting, potentially leading to non-uniform products. In two pilot experiments using biosolids and green waste (1:1; v:v), thermophilic conditions (>45°C) were maintained for two months, with successful control of oxygen levels and sufficient moisture. Emitted odors declined from 1.5-3.8×10 5 to 5.9×10 3 -2.3×10 4 odor units m -3 -air in the first 3weeks of the process, emphasizing the need of odor control primarily during this period. Therefore, composting might be managed in two phases: (i) a closed sleeve for 6-8weeks during which the odor is treated; (ii) an open pile (odor control is not necessary). Reduction of salmonella, E. coli and coliforms was effective initially, meeting the standards of "Class A" biosolids; however, total and fecal coliforms density increased after opening the second sleeve and exceeded the standard of 1000 most probable number (MPN) per g dry matter. Compost maturity was achieved in the open piles following the two sleeves and the final compost was non-phytotoxic and beneficial as a soil additive. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Structure and properties of braided sleeve preforms for chemical vapor infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Starr, T.L.; Fiadzo, O.G.; Hablutzel, N. [Georgia Inst. of Tech., Atlanta, GA (United States). School of Materials Science and Technology

    1998-04-01

    In all composites the properties and structure of the reinforcement strongly influence the performance of the material. For some composites, however, the reinforcement also affects the fabrication process itself exerting an additional, second order influence on performance. This is the case for the chemical vapor infiltration (CVI) process for fabrication of ceramic matrix composites. In this process the matrix forms progressively as a solid deposit, first onto the fiber surfaces, then onto the previous layer of deposit, ultimately growing to fill the inter-fiber porosity. The transport of reactants to the surfaces and the evolved morphology of the matrix depend on the initial reinforcement structure. This structure can vary greatly and is controlled by such factors as fiber size and cross-section, the number of filaments and amount of twist per tow or yarn, and the weave or braid architecture. Often the choice of reinforcement is based on mechanical performance analysis or on the cost and availability of the material or on the temperature stability of the fiber. Given this choice, the composite densification process--CVI--must be optimized to attain a successful material. Ceramic fiber in the form of cylindrical braided sleeve is an attractive choice for fabrication of tube-form ceramic matrix composites. Multiple, concentric layers of sleeve can be placed over a tubular mandrel, compressed and fixed with a binder to form a freestanding tube preform. This fiber architecture is different than that created by layup of plain weave cloth--the material used in most previous CVI development. This report presents the results of the investigation of CVI densification of braided sleeve preforms and the evolution of their structure and transport properties during processing.

  8. Effect of Sleeve Plunge Depth on Microstructure and Mechanical Properties of Refill Friction Stir Spot Welding of 2198 Aluminum Alloy

    Science.gov (United States)

    Yue, Yumei; Shi, Yao; Ji, Shude; Wang, Yue; Li, Zhengwei

    2017-10-01

    Refill friction stir spot welding (RFSSW) is a new spot welding technology, by which spot joint without keyhole can be obtained. In this work, RFSSW was used to join 2-mm-thick 2198-T8 aluminum alloy sheets and effects of the sleeve plunge depth on microstructure and lap shear properties of the joints were mainly discussed. Results showed that when using small plunge depths of 2.4 and 2.6 mm, joints showed good formation and no defects were observed. Incomplete refilling defect was observed with increasing plunge depth due to material loss during welding. Size of the grains at sleeve-affected zone (SAZ) is smaller than that at the pin-affected zone, and the size becomes bigger with increasing the plunge depth. More secondary phase particles can be observed at SAZ with increasing the sleeve plunge depth. The lap shear failure load firstly increased and then decreased with increasing the sleeve plunge depth. The maximum failure load of 9819 N was attained with plug fracture mode when using 2.6 mm. Fracture morphologies show ductile fracture mode.

  9. Concurrent Mesh Repair of a Morgagni and Umbilical Hernia during a Laparoscopic Sleeve Gastrectomy in a Morbidly Obese Individual

    Directory of Open Access Journals (Sweden)

    N.R Kosai

    2016-10-01

    Full Text Available Morgagni Hernia is a rare form of diaphragmatic hernia. It is mainly asymptomatic and often identified incidentally during surgery. Tension-free synthetic mesh repair is the preferred treatment modality. However, the use of synthetic mesh concurrently during a clean-contaminated surgery such as sleeve gastrectomy remains controversial due to the remote possibility of mesh infection. A middle-aged female 2 with BMI of 47 Kg/m was admitted electively for laparoscopic sleeve gastrectomy with concurrent umbilical hernia repair. Intra-operatively, a left Morgagni Hernia containing omentum and a segment of transverse colon was noted. She underwent a laparoscopic sleeve gastrectomy and simultaneous laparoscopic tension-free composite mesh repair of both Morgagni and umbilical hernia. Outpatient review three months later revealed excess weight loss of almost 30% with no recurrence of either hernia. In conclusion, the advantages of concurrent hernia repair during bariatric surgery outweigh the risk of mesh infection and should be performed to prevent future risk of visceral herniation and strangulation. Laparoscopic mesh repair of a Morgagni Hernia and umbilical hernia in the setting of an electively planned sleeve gastrectomy is feasible, effective and safe in the hands of a trained laparoscopic surgeon.

  10. pH monitoring of gastro-oesophageal reflux before and after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Thereaux, J; Barsamian, C; Bretault, M; Dusaussoy, H; Lamarque, D; Bouillot, J-L; Czernichow, S; Carette, C

    2016-03-01

    Gastro-oesophageal reflux disease (GORD) is a common obesity-related co-morbidity that is assessed objectively by 24-h pH monitoring. Some concerns have been raised regarding the risk of de novo GORD or exacerbation of pre-existing GORD after laparoscopic sleeve gastrectomy. Here, 24-h pH monitoring was used to assess the influence of laparoscopic sleeve gastrectomy on postoperative GORD in obese patients with or without preoperative GORD. From July 2012 to September 2014, all patients scheduled for laparoscopic sleeve gastrectomy were invited to participate in a prospective follow-up. Patients who underwent preoperative 24-h pH monitoring were asked to repeat the examination 6 months after operation. GORD was defined as an oesophageal pH < 4 for at least 4·2 per cent of the total time recorded. Of 89 patients, 76 had preoperative pH monitoring for GORD evaluation and 50 had postoperative reassessment. Patients without (group 1, 29 patients) or with (group 2, 21 patients) preoperative GORD were similar regarding age, sex ratio and body mass index. In group 1, the median (i.q.r.) total time at pH < 4 was significantly higher after surgery than before: 5·6 (2·5-9·5) versus 1·6 (0·7-2·9) per cent (P < 0·001). Twenty of the 29 patients experienced de novo GORD as determined by 24-h pH monitoring (P < 0·001). In group 2, total time at pH < 4 after surgery was no different from the preoperative value: 5·9 (3·9-10·7) versus 7·7 (5·2-10·3) per cent (P = 0·296). Laparoscopic sleeve gastrectomy was associated with de novo GORD in over two-thirds of patients, but did not seem to exacerbate existing GORD. © 2016 BJS Society Ltd Published by John Wiley & Sons Ltd.

  11. The Single Needle Lockstitch Machine. [Constructing and Setting Sleeves.] Module 7.

    Science.gov (United States)

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on constructing and setting sleeves, one in a series on the single needle lockstitch sewing machine for student self-study, contains two sections. Each section includes the following parts: an introduction, directions, an objective, learning activities, student information, student self-check, check-out activities, and an instructor's…

  12. Pulmonary artery reconstruction with a tailor-made bovine pericardial conduit following sleeve resection of a long segmental pulmonary artery for the treatment of lung cancer: technical details of the dog-ear method for adjusting diameter during vascular anastomosis.

    Science.gov (United States)

    Shimizu, Kimihiro; Nagashima, Toshiteru; Ohtaki, Yoichi; Takahashi, Toru; Mogi, Akira; Kuwano, Hiroyuki

    2017-05-01

    Sleeve resection of the pulmonary artery (PA) is always required for lung-sparing operations in which half or more of the vessel circumference is infiltrated by the primary tumor or metastatic hilar nodes. Following sleeve resection, conduit reconstruction may be indicated if there is excessive distance between the two vascular stumps, because there is a high degree of tension when repaired by direct anastomosis. We herein present a case of PA reconstruction using a tailor-made bovine pericardial conduit after sleeve resection of PA during lung cancer surgery. The length of resection was longer than 3 cm, and the difference in diameter between the conduit and peripheral PA stump was larger than 0.5 cm. We describe the surgical and oncological merits of a bovine pericardial conduit, and provide details of our reconstruction technique, focusing on adjustment of diameter between the conduit and peripheral PA (dog-ear method).

  13. Endurance in Al Alloy Melts and Wear Resistance of Titanium Matrix Composite Shot-Sleeve for Aluminum Alloy Die-casting

    International Nuclear Information System (INIS)

    Choi, Bong-Jae; Kim, Young-Jig; Sung, Si-Young

    2012-01-01

    The main purpose of this study was to evaluate the endurance against Al alloy melts and wear resistance of an in-situ synthesized titanium matrix composite (TMC) sleeve for aluminum alloy die-casting. The conventional die-casting shot sleeve material was STD61 tool steel. TMCs have great thermal stability, wear and oxidation resistance. The in-situ reaction between Ti and B4C leads to two kinds of thermodynamically stable reinforcements, such as TiBw and TiCp. To evaluate the feasibility of the application to a TMCs diecasting shot sleeve, the interfacial reaction behavior was examined between Al alloys melts with TMCs and STD61 tool steel. The pin-on-disk type dry sliding wear test was also investigated for TMCs and STD61 tool steel.

  14. Biological conduit small gap sleeve bridging method for peripheral nerve injury: regeneration law of nerve fibers in the conduit

    Directory of Open Access Journals (Sweden)

    Pei-xun Zhang

    2015-01-01

    Full Text Available The clinical effects of 2-mm small gap sleeve bridging of the biological conduit to repair peripheral nerve injury are better than in the traditional epineurium suture, so it is possible to replace the epineurium suture in the treatment of peripheral nerve injury. This study sought to identify the regeneration law of nerve fibers in the biological conduit. A nerve regeneration chamber was constructed in models of sciatic nerve injury using 2-mm small gap sleeve bridging of a biodegradable biological conduit. The results showed that the biological conduit had good histocompatibility. Tissue and cell apoptosis in the conduit apparently lessened, and regenerating nerve fibers were common. The degeneration regeneration law of Schwann cells and axons in the conduit was quite different from that in traditional epineurium suture. During the prime period for nerve fiber regeneration (2-8 weeks, the number of Schwann cells and nerve fibers was higher in both proximal and distal ends, and the effects of the small gap sleeve bridging method were better than those of the traditional epineurium suture. The above results provide an objective and reliable theoretical basis for the clinical application of the biological conduit small gap sleeve bridging method to repair peripheral nerve injury.

  15. Control of Cocoa Pod Borer and Phytophthora Pod Rot Using Degradable Plastic Pod Sleeves and a Nematode, Steinernema Carpocapsae

    OpenAIRE

    Rosmana, Ade; Shepard, Merle; Hebbar, Prakash; Mustari, Anita

    2010-01-01

    Cocoa pod borer (CPB; Conopomorpha cramerella) and Phytophthora pod rot (PPR; Phytophthora palmivora) are serious pest and disease on cocoa plantations in Indonesia. Both pest and disease have been controlled with limited success using cultural practices such as pruning, frequent harvesting, sanitation, plastic sleeving, and chemical pesticides. An experiment was conducted on cocoa plantings in Pinrang Regency, South Sulawesi during the wet season of 2008/09 to test the effect of pod sleeving...

  16. Extended Sleeve Products Allow Control and Monitoring of Process Fluid Flows Inside Shielding, Behind Walls and Beneath Floors - 13041

    Energy Technology Data Exchange (ETDEWEB)

    Abbott, Mark W. [Flowserve Corporation, 1978 Foreman Drive Cookeville, TN 38506 (United States)

    2013-07-01

    Throughout power generation, delivery and waste remediation, the ability to control process streams in difficult or impossible locations becomes increasingly necessary as the complexity of processes increases. Example applications include radioactive environments, inside concrete installations, buried in dirt, or inside a shielded or insulated pipe. In these situations, it is necessary to implement innovative solutions to tackle such issues as valve maintenance, valve control from remote locations, equipment cleaning in hazardous environments, and flow stream analysis. The Extended Sleeve family of products provides a scalable solution to tackle some of the most challenging applications in hazardous environments which require flow stream control and monitoring. The Extended Sleeve family of products is defined in three groups: Extended Sleeve (ESV), Extended Bonnet (EBV) and Instrument Enclosure (IE). Each of the products provides a variation on the same requirements: to provide access to the internals of a valve, or to monitor the fluid passing through the pipeline through shielding around the process pipe. The shielding can be as simple as a grout filled pipe covering a process pipe or as complex as a concrete deck protecting a room in which the valves and pipes pass through at varying elevations. Extended Sleeves are available between roughly 30 inches and 18 feet of distance between the pipeline centerline and the top of the surface to which it mounts. The Extended Sleeve provides features such as ± 1.5 inches of adjustment between the pipeline and deck location, internal flush capabilities, automatic alignment of the internal components during assembly and integrated actuator mounting pads. The Extended Bonnet is a shorter fixed height version of the Extended Sleeve which has a removable deck flange to facilitate installation through walls, and is delivered fully assembled. The Instrument Enclosure utilizes many of the same components as an Extended Sleeve

  17. Repair boundary for parent tube indications within the upper joint zone of hybrid expansion joint (HEJ) sleeved tubes

    International Nuclear Information System (INIS)

    Cullen, W.K.; Keating, R.F.

    1997-01-01

    In the Spring and Fall of 1994, and the Spring of 1995, crack-like indications were found in the upper hybrid expansion joint (HEJ) region of Steam Generator (S/G) tubes which had been sleeved using Westinghouse HEJ sleeves. As a result of these findings, analytic and test evaluations were performed to assess the effect of the degradation on the structural, and leakage, integrity of the sleeve/tube joint relative to the requirements of the United States Nuclear Regulatory Commission's (NRC) draft Regulatory Guide (RG) 1.121. The results of these evaluations demonstrated that tubes with implied or known crack-like circumferential parent tube indications (PTIs) located 1.1 inches or farther below the bottom of the hardroll upper transition, have sufficient, and significant, integrity relative to the requirements of RG 1.121. Thus, the purpose of this report is to provide background information related to the justification of the modified tube repair boundary

  18. Behandling med duodenal-jejunal bypass-sleeve ved svær overvægt

    DEFF Research Database (Denmark)

    Rohde, Ulrich; Gylvin, Silas; Vilmann, Peter

    2014-01-01

    Overweight and obesity are risk factors for several co-morbidities reducing life expectancy. Conservative treatment of obesity is generally ineffective in the long-term. Bariatric surgery has proven effective, but is associated with potential complications. Duodenal-jejunal bypass sleeve is a novel...

  19. Laparoscopic sleeve gastrectomy and gastroesophageal reflux disease : a systematic review and meta-analysis

    NARCIS (Netherlands)

    Oor, Jelmer E; Roks, David J; Ünlü, Çagdas; Hazebroek, Eric J

    BACKGROUND: The effect of sleeve gastrectomy (SG) on the prevalence of gastroesophageal reflux disease (GERD) remains unclear. We aimed to outline the currently available literature. DATA SOURCES: All relevant databases were searched for publications examining the effect of laparoscopic SG on GERD.

  20. Feasibility and early outcomes of laparoscopic plicated sleeve gastrectomy: a case-control study

    Directory of Open Access Journals (Sweden)

    Tomasz Rogula

    2016-01-01

    Full Text Available Introduction : Sleeve gastrectomy (SG continues to gain popularity as a viable weight loss procedure with well-documented outcomes and procedure-specific adverse effects. It has become increasingly indicated for the treatment of morbid obesity. Aim of the research : To compare a novel approach to SG, which aims to reduce SG-specific complications, to the standard SG procedure. Material and methods : Sixteen morbidly obese patients with a mean body mass index (BMI of 48.5 kg/m 2 ± SD who underwent the novel laparoscopic plicated sleeve gastrectomy (LPSG were retrospectively studied. The control group included 18 patients who underwent laparoscopic SG. Study and control groups were matched for BMI and gender. Study group patients underwent a partial SG with imbrication of the distal 2/3 of the staple line with 2 cm overlap and 3–4 cm of the pre-pyloric stomach. Control group SG patients had their staple line oversewn without plication. Outcomes at 3, 6 and 12 months were compared and analyzed. Results: There was no statistically significant difference in weight loss at 12 months between the LPSG and SG groups. Postoperative nausea was comparable between the two groups. No major complications were noted in either group. Conclusions: The LPSG is a modification of the standard SG which has comparable outcomes, safety and feasibility. It may lead to a decrease in unwanted complications such as sleeve stricture or obstruction. Further studies on long-term outcomes are needed to assess its value as a bariatric procedure.

  1. More stapler firings increase the risk of perioperative morbidity after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Major, Piotr; Wysocki, Michał; Pędziwiatr, Michał; Pisarska, Magdalena; Małczak, Piotr; Wierdak, Mateusz; Dembiński, Marcin; Migaczewski, Marcin; Rubinkiewicz, Mateusz; Budzyński, Andrzej

    2018-03-01

    Staple-line bleeding and leakage are the most common serious complications of laparoscopic sleeve gastrectomy. The relationship between multiple stapler firings and higher risk of postoperative complications is well defined in colorectal surgery but has not been addressed in bariatric procedures so far. Identification of new factors such as "the numbers of stapler firings used during laparoscopic sleeve gastrectomy (LSG)" as a predictor for complications can lead to optimization of the patient care at bariatric centers. To determine the association between perioperative morbidity and the number of stapler firings during laparoscopic sleeve gastrectomy. This observational study was based on retrospective analysis of prospectively collected data in patients operated on for morbid obesity in a teaching hospital/tertiary referral center for general surgery. The patients who underwent LSG were analyzed in terms of the number of stapler firings used as a new potential risk predictor for postoperative complications after surgery, adjusting for other patient- and treatment-related factors. The study included 333 patients (209 women, 124 men, mean age: 40 ±11). During the first 30 days after surgery, complications were observed in 18 (5.41%) patients. Multivariate analysis showed that prolonging operative time increased morbidity (every minute, OR = 1.01; 95% CI: 1.00-1.02) and the complication rate increased with the number of stapler firings (every firing, OR = 1.91; 95% CI: 1.09-3.33; p = 0.023). Additional stapler firings above the usual number and a prolonged operation should alert a surgeon and the whole team about increased risk of postoperative complications.

  2. Ultrasound-guided subcostal-posterior transversus abdominis plane block for pain control following laparoscopic sleeve gastrectomy

    Directory of Open Access Journals (Sweden)

    Dilek E. Arı

    2017-12-01

    Full Text Available Objectives: To investigate the analgesic effect of a subcostal-posterior transversus abdominis plane (TAP block combination following laparoscopic sleeve gastrectomy. Methods: This study was conducted at Fatih Sultan Mehmet Educational and Research Hospital, Istanbul, Turkey, between March 2014 and June 2015. A total of 40 patients with a body mass index of 40-60 kg/m2 scheduled for laparoscopic sleeve gastrectomy were randomly allocated into 2 groups. Patients in Group I (n=20 received a bilateral subcostal TAP block, and patients in Group II (n=20 received a bilateral subcostal and posterior TAP block. Pain intensity was assessed at rest and during coughing using the visual analog scale (VAS prior to and at various time points after TAP block (0 min, 30 min, 2 hours, 4 hours, 6 hours, 12 hours, and 24 hours. Morphine consumption over 24 hours and time to first morphine requirement were recorded. Results: There was no difference in VAS scores between groups. Morphine consumption was 6.78±5.95 mg in Group I, and 7.28±5.95 mg in Group II (p=0.795. Time to first morphine requirement was 267.22±303.84 min for Group I, and 207.80±209.81 min for Group II (p=0.154. Conclusions: Subcostal-posterior TAP block provided equivalent analgesia to subcostal TAP block alone following laparoscopic sleeve gastrectomy.

  3. Thermoelastic/plastic analysis of waste-container sleeve: IV. Air gap influence on hole closure. Technical memorandum report (RSI-0019)

    International Nuclear Information System (INIS)

    Pariseau, W.G.

    1975-01-01

    A thermoelastic/plastic finite element analysis of the influence of an air-gap on hole closure about a waste-container/sleeve assembly emplaced in a typical repository room (SALT/4T Model) indicates that hole closure would be of the order of hundredths of an inch. Acceptable air-gap width is thus governed by the hole size required for emplacement efficiency. A refined mesh analysis and laboratory testing is suggested in order to further explore the possibility of eliminating the engineering necessity of the sleeve

  4. Effect of Laparoscopic Sleeve Gastrectomy vs Laparoscopic Roux-en-Y Gastric Bypass on Weight Loss at 5 Years Among Patients With Morbid Obesity: The SLEEVEPASS Randomized Clinical Trial.

    Science.gov (United States)

    Salminen, Paulina; Helmiö, Mika; Ovaska, Jari; Juuti, Anne; Leivonen, Marja; Peromaa-Haavisto, Pipsa; Hurme, Saija; Soinio, Minna; Nuutila, Pirjo; Victorzon, Mikael

    2018-01-16

    Laparoscopic sleeve gastrectomy for treatment of morbid obesity has increased substantially despite the lack of long-term results compared with laparoscopic Roux-en-Y gastric bypass. To determine whether laparoscopic sleeve gastrectomy and laparoscopic Roux-en-Y gastric bypass are equivalent for weight loss at 5 years in patients with morbid obesity. The Sleeve vs Bypass (SLEEVEPASS) multicenter, multisurgeon, open-label, randomized clinical equivalence trial was conducted from March 2008 until June 2010 in Finland. The trial enrolled 240 morbidly obese patients aged 18 to 60 years, who were randomly assigned to sleeve gastrectomy or gastric bypass with a 5-year follow-up period (last follow-up, October 14, 2015). Laparoscopic sleeve gastrectomy (n = 121) or laparoscopic Roux-en-Y gastric bypass (n = 119). The primary end point was weight loss evaluated by percentage excess weight loss. Prespecified equivalence margins for the clinical significance of weight loss differences between gastric bypass and sleeve gastrectomy were -9% to +9% excess weight loss. Secondary end points included resolution of comorbidities, improvement of quality of life (QOL), all adverse events (overall morbidity), and mortality. Among 240 patients randomized (mean age, 48 [SD, 9] years; mean baseline body mass index, 45.9, [SD, 6.0]; 69.6% women), 80.4% completed the 5-year follow-up. At baseline, 42.1% had type 2 diabetes, 34.6% dyslipidemia, and 70.8% hypertension. The estimated mean percentage excess weight loss at 5 years was 49% (95% CI, 45%-52%) after sleeve gastrectomy and 57% (95% CI, 53%-61%) after gastric bypass (difference, 8.2 percentage units [95% CI, 3.2%-13.2%], higher in the gastric bypass group) and did not meet criteria for equivalence. Complete or partial remission of type 2 diabetes was seen in 37% (n = 15/41) after sleeve gastrectomy and in 45% (n = 18/40) after gastric bypass (P > .99). Medication for dyslipidemia was discontinued in 47% (n

  5. Numerical Simulation and Experimental Validation of an Integrated Sleeve-Wedge Anchorage for CFRP Rods

    DEFF Research Database (Denmark)

    Schmidt, Jacob Wittrup; Smith, Scott T.; Täljsten, Björn

    2011-01-01

    . Recently, an integrated sleeve-wedge anchorage has been successfully developed specifically for CFRP rods. This paper in turn presents a numerical simulation of the newly developed anchorage using ABAQUS. The three-dimensional finite element (FE) model, which considers material non-linearity, uses...

  6. Plume and Dose Modeling Performed to Assess Waste Management Enhancements Associated with Envirocare's Decision to Purchase of an Engineered Rail Rollover Facility Enclosure

    International Nuclear Information System (INIS)

    Rogers, T.; Clayman, B.

    2003-01-01

    This paper describes the modeling performed on a proposed enclosure for the existing railcar rollover facility located in Clive, Utah at a radioactive waste disposal site owned and operated by Envirocare of Utah, Inc. (Envirocare). The dose and plume modeling information was used as a tool to justify the decision to make the capital purchase and realize the modeled performance enhancements

  7. Effects of sleeve blockages on axial velocity and intensity of turbulence in an unheated 7 x 7 rod bundle

    International Nuclear Information System (INIS)

    Creer, J.M.; Rowe, D.S.; Bates, J.M.; Sutey, A.M.

    1976-01-01

    An experimental study is described which was performed to investigate the turbulent flow phenomena near postulated sleeve blockages in a model nuclear fuel rod bundle. The sleeve blockages were characteristic of fuel clad ''swelling'' or ''ballooning'' which could occur during loss-of-coolant accidents (LOCA) in pressurized water reactors. The study was conducted to provide information relative to the flow phenomena near postulated blockages to support detailed safety analyses of LOCAs. The results of the study are especially useful for verification of the hydraulic treatment of reactor core computer programs such as COBRA

  8. Management of a case of left tracheal sleeve pneumonectomy under cardiopulmonary bypass: Anesthesia perspectives

    Directory of Open Access Journals (Sweden)

    Aman Jyoti

    2014-01-01

    Full Text Available The lung tumors with carinal involvement are frequently managed with tracheal sleeve pneumonectomy and tracheobronchial anastomosis without use of cardiopulmonary bypass (CPB. Various modes of ventilation have been described during tracheal resection and anastomosis. Use of CPB during this period allows the procedure to be conducted in a more controlled way. We performed tracheal sleeve pneumonectomy for adenoid cystic carcinoma of left lung involving carina. The surgery was performed in two stages. In the first stage, left pneumonectomy was performed and in the second stage after 48 h, tracheobronchial resection and anastomosis was performed under CPB. Second stage was delayed to avoid excessive bleeding (due to heparinization from the extensive vascular raw area left after pneumonectomy. Meticulous peri-operative planning and optimal post-operative care helped in successful management of a complex case, which is associated with high morbidity and mortality.

  9. Dietary intake and ghrelin and leptin changes after sleeve gastrectomy

    OpenAIRE

    Bu?ga, Marek; Zavadilov?, Vladislava; Hol?czy, Pavol; ?vagera, Zden?k; ?vorc, Pavol; Foltys, Ale?; Zon?a, Pavel

    2014-01-01

    Introduction Surgical intervention in obesity is today the most effective treatment method in high level obesity management. Bariatric interventions not only ensure body weight reduction, but may influence dietary habits. Aim To assess changes in adipose hormones and dietary habits in obese patients after sleeve gastrectomy. Material and methods The study set comprised 37 subjects (29 females and 8 males) 24 to 68 years old with body mass index 43.0 ?4.9 kg/m2. Pre-operative examination inclu...

  10. Effect of Yaw Angle and Ambient Wind on Fabric Penetration of a Simulated Sleeve

    Science.gov (United States)

    2015-08-20

    took a day of trial-and-error testing. Of concern is the effect of the fabric sleeve on the flowfield. It is possible that the introduction of the...stephanie.f.zopf.civ@mail.mil CLARKSON UNIVERSITY (1) Mechanical Engineering Department 8 Clarkson Ave., Potsdam , NY 13699 sdhaniyala

  11. Getting the most from the sleeve: the importance of post-operative follow-up.

    Science.gov (United States)

    Keren, Dean; Matter, Ibrahim; Rainis, Tova; Lavy, Alexandra

    2011-12-01

    Bariatric approach to obesity provides substantial weight loss and comorbidity resolution. Our unique service includes pre- and postoperative visits to the Health and Nutrition Clinic headed by a specialist in gastroenterology and nutrition. We compared patients attending regular clinic routine with those who were lost to follow-up with regard to anthropometry, comorbidity, quality of life, and food tolerance and determined who benefited most from the operation. A retrospective review was performed on patients 30 months after undergoing sleeve gastrectomy. Body mass index was used to report weight loss. Bariatric Analysis and Reporting Outcome System (BAROS) and Food Tolerance Score were (FTS) completed by all patients at the 30-month follow-up visit and compared between two groups (group I-30 months of active postoperative follow-up; group II-without). A total of 119 patients participated in the study. For groups I and II, the mean percentage of excess BMI loss at 30 months was 82.08 ± 9.83 and 74.88 ± 8.75, respectively, with better comorbidity improvement in group I. BAROS scores were 7.62 ± 0.72 and 6.92 ± 0.92. FTS was 24.30 ± 2.09 and 22.55 ± 2.27, respectively. From our experience, getting the most from the sleeve is attributed to two main factors: surgery and nutrition. Surgery results in optimal restriction and improved satiety, whereas nutrition relies on a professional medical team providing constant, ongoing patient support throughout all the bariatric process stages. These teams of surgeons and gastroenterologists specializing in nutrition, working side by side, each in their area of specialty, are the main pillars leading to the success of the sleeve.

  12. Development of laser materials processing and laser metrology techniques

    International Nuclear Information System (INIS)

    Kim, Cheol Jung; Chung, Chin Man; Kim, Jeong Mook; Kim, Min Suk; Kim, Kwang Suk; Baik, Sung Hoon; Kim, Seong Ouk; Park, Seung Kyu

    1997-09-01

    The applications of remote laser materials processing and metrology have been investigated in nuclear industry from the beginning of laser invention because they can reduce the risks of workers in the hostile environment by remote operation. The objective of this project is the development of laser material processing and metrology techniques for repairing and inspection to improve the safety of nuclear power plants. As to repairing, we developed our own laser sleeve welding head and innovative optical laser weld monitoring techniques to control the sleeve welding process. Furthermore, we designed and fabricated a 800 W Nd:YAG and a 150 W Excimer laser systems for high power laser materials processing in nuclear industry such as cladding and decontamination. As to inspection, we developed an ESPI and a laser triangulation 3-D profile measurement system for defect detection which can complement ECT and UT inspections. We also developed a scanning laser vibrometer for remote vibration measurement of large structures and tested its performance. (author). 58 refs., 16 tabs., 137 figs

  13. THE ROLL-OVER OF HELIOSPHERIC NEUTRAL HYDROGEN BELOW 100 eV: OBSERVATIONS AND IMPLICATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Galli, A.; Wurz, P. [Physics Institute, University of Bern, Bern, 3012 (Switzerland); Schwadron, N. A.; Kucharek, H.; Möbius, E. [University of New Hampshire, Durham, NH 03824 (United States); Bzowski, M.; Sokół, J. M.; Kubiak, M. A. [Space Research Centre, Polish Academy of Sciences, Warsaw, 00-716 (Poland); Funsten, H. O. [Los Alamos National Laboratory, Intelligence and Space Research Division, Los Alamos, NM 87545 (United States); Fuselier, S. A.; McComas, D. J. [Southwest Research Institute, San Antonio, TX 78228 (United States)

    2016-04-20

    We present an improved analysis of the energy spectrum of energetic neutral hydrogen from the heliosheath observed with the IBEX -Lo sensor on the Interstellar Boundary EXplorer from the years 2009 to 2012. This analysis allows us to study the lowest energies between 10 and 100 eV although various background sources are more intense than the targeted signal over broad areas of the sky. The results improve our knowledge of the interaction region between our heliosphere and the interstellar plasma because these neutral atoms are direct messengers from the low-energy plasma in the heliosheath. We find a roll-over of the energy spectrum below 100 eV, which has major implications for the pressure balance of the plasma in the inner heliosheath. The results can also be compared directly with in situ observations of the Voyager 1 and 2 spacecraft.

  14. Pediatric laparoscopic sleeve gastrectomy in Turkey: Short-term results.

    Science.gov (United States)

    Ates, Ufuk; Ergun, Ergun; Gollu, Gulnur; Sozduyar, Sumeyye; Can, Ozlem Selvi; Yagmurlu, Aydin

    2018-05-01

    Obesity is one of the most rapidly increasing health problems in children. Laparoscopic sleeve gastrectomy (LSG) is one of the best treatment options and is feasible and safe in children. The aim of this study was to present the short-term results of a laparoscopic sleeve gastrectomy series in children. Children who underwent LSG in 2014-2017 were included in the study. Charts were investigated retrospectively and short-term weight loss was analyzed. Patients who had surgery in 2014-2017 were included in the study. There were six girls and two boys, and the median age was 15 years (range, 11-18 years). Mean weight was 159.25 ± 19.78 kg, and mean body mass index was 61.05 ± 8.5 kg/m 2 . Mean operation time was 70 min (range, 65-90 min), mean hospital stay was 5.1 days (range, 3-7 days), and mean follow up was 19.2 months (range, 1-43 months). Of these patients, five had hypertension and were under medication and two of these five also had hyperinsulinemia. One of the five children had Bardet-Biedl syndrome and one had bronchial asthma. After operation, medication was stopped in four of the eight children. At the time of writing, six patients were doing well without postoperative complications, or the need for reoperation. Even though the follow-up period was short and the number of patients was small, LSG was a feasible and promising surgical method for morbidly obese children. A multidisciplinary approach and lifelong behavior therapy are key steps for success. © 2018 Japan Pediatric Society.

  15. Experimental consolidation of granulated rock salt with application to sleeve buckling. Technical memorandum report RSI-0044

    International Nuclear Information System (INIS)

    Hansen, F.D.

    1976-01-01

    Quasi-static and creep consolidation tests have been performed in order to determine the compressibility of granulated rock salt when subjected to uniaxial deformations. The purpose of this analysis is to evaluate the force-displacement characteristics of rock salt that may be used as a backfill material around waste canister sleeves. The test set-up involved placing rock salt pellets in a thin-walled steel cylinder and applying a uniaxial load which compressed the salt while allowing no lateral movement. Tests were run at room temperature, 100 and 200 0 C and consolidated to uniaxial stress levels between 1000 and 4000 psi. Axial force, displacement and time were monitored during each test and the relationships have been evaluated. In particular, compressibility of the rock salt is not drastically effected by the temperature differences, nor is there an appreciable difference between the consolidation tests that were allowed to creep and those that were tested quasi-statically. On the basis of experimental data relating volume change to uniaxial stress, the pressure on the waste canister sleeve has been shown to be a nonlinear function of drillhole displacement. For a proposed in situ field test geometry, a 16 inch drillhole and a canister with a 12.75 inch O.D., the pressure necessary to buckle the canister sleeve will develop when the drillhole closes diametrically 0.5 to 0.6 inches. By the nature of this experimental effort, the results obtained are conservative

  16. The Effects of Bougie Diameters on Tissue Oxygen Levels After Sleeve Gastrectomy: A Randomized Experimental Trial

    Directory of Open Access Journals (Sweden)

    Can Konca

    2018-05-01

    Full Text Available Background: Staple-line leak is the most frightening complication of laparoscopic sleeve gastrectomy and several predisposing factors such as using improper staple sizes regardless of gastric wall thickness, narrower bougie diameter and ischemia of the staple line are asserted. Aims: To evaluate the effects of different bougie diameters on tissue oxygen partial pressure at the esophagogastric junction after sleeve gastrectomy. Study Design: A randomized and controlled animal experiment with 1:1:1:1 allocation ratio. Methods: Thirty-two male Wistar Albino rats were randomly divided into 4 groups of 8 each. While 12-Fr bougies were used in groups 1 and 3, 8-Fr bougies were used in groups 2 and 4. Fibrin sealant application was also carried out around the gastrectomy line after sleeve gastrectomy in groups 3 and 4. Burst pressure of gastrectomy line, tissue oxygen partial pressure and hydroxyproline levels at the esophagogastric junction were measured and compared among groups. Results: Mortality was detected in 2 out of 32 rats (6.25% and one of them was in group 2 and the cause of this mortality was gastric leak. Gastric leak was detected in 2 out of 32 rats (6.25%. There was no significant difference in terms of burst pressures, tissue oxygen partial pressure and tissue hydroxyproline levels among the 4 groups. Conclusion: The use of narrower bougie along with fibrin sealant has not had a negative effect on tissue perfusion and wound healing.

  17. Irradiation-induced dimensional changes of fuel compacts and graphite sleeves of OGL-1 fuel assemblies

    International Nuclear Information System (INIS)

    Hayashi, Kimio; Minato, Kazuo; Kobayashi, Fumiaki; Tobita, Tsutomu; Kikuchi, Teruo; Kurobane, Shiro; Adachi, Mamoru; Fukuda, Kousaku

    1988-06-01

    Experimental data are summarized on irradiation-induced dimensional changes of fuel compacts and graphite sleeves of the first to ninth OGL-1 fuel assemblies. The range of fast-neutron fluence is up to 4 x 10 24 n/m 2 (E > 0.18 MeV); and that of irradiation temperature is 900 - 1400 deg C for fuel compacts and 800 - 1050 deg C for graphite sleeves. The dimensional change of the fuel compacts was shrinkage under these test conditions, and the shrinkage fraction increased almost linearly with fast-neutron fluence. The shrinkage fraction of the fuel compacts was larger by 20 % in the axial direction than in the radial direction. Influence of the irradiation temperature on the dimensional-change behavior of the fuel compacts was not observed clearly; presumably the influence was hidden by scatter of the data because of low level of the fast-neutron fluence and the resultant small dimensional changes. (author)

  18. Prevalence of Chronic Gastritis or Helicobacter pylori Infection in Adolescent Sleeve Gastrectomy Patients Does Not Correlate with Symptoms or Surgical Outcomes.

    Science.gov (United States)

    Franklin, Ashanti L; Koeck, Emily S; Hamrick, Miller C; Qureshi, Faisal G; Nadler, Evan P

    2015-08-01

    In adults undergoing gastric bypass surgery, it is routine practice to perform pre-operative testing for Helicobacter pylori infection. Evidence suggests that infection impairs anastomotic healing and contributes to complications. There currently are no data for adolescents undergoing bariatric procedures. Despite few patients with pre-operative symptoms, we noted occasional patients with H. pylori detected after sleeve gastrectomy. We reviewed our experience with our adolescent sleeve gastrectomy cohort to determine the prevalence of H. pylori infection, its predictive factors, and association with outcomes. We hypothesized that H. pylori infection would be associated with pre-operative symptoms, but not surgical outcomes. All patients undergoing sleeve gastrectomy at our hospital were included. We conducted a chart review to determine pre- or post-operative symptoms of gastroesophageal reflux disease GERD or gastritis, operative complications, and long-term anti-reflux therapy after surgery. Pathology reports were reviewed for evidence of gastritis and H. pylori infection. 78 adolescents had laparoscopic sleeve gastrectomy from January 2010 through July 2014. The prevalence of chronic gastritis was 44.9% (35/78) and 11.4% of those patients had H. pylori (4/35). Only one patient with H. pylori had pre-operative symptoms, and only 25.7% (9/35) of patients with pathology-proven gastritis had symptoms. One staple line leak occurred but this patient did not have H. pylori or gastritis. Mean patient follow-up was 10 (3-26) mos. There is a moderate prevalence of gastritis among adolescents undergoing sleeve gastrectomy, but only a small number of these patients had H. pylori infection. Neither the presence of chronic gastritis nor H. pylori infection correlated with symptoms or outcomes. Thus, in the absence of predictive symptomology or adverse outcome in those who are infected, we advocate for continued routine pathologic evaluation without the required need for pre

  19. Rotating-Sleeve Triboelectric-Electromagnetic Hybrid Nanogenerator for High Efficiency of Harvesting Mechanical Energy.

    Science.gov (United States)

    Cao, Ran; Zhou, Tao; Wang, Bin; Yin, Yingying; Yuan, Zuqing; Li, Congju; Wang, Zhong Lin

    2017-08-22

    Currently, a triboelectric nanogenerator (TENG) and an electromagnetic generator (EMG) have been hybridized to effectively scavenge mechanical energy. However, one critical issue of the hybrid device is the limited output power due to the mismatched output impedance between the two generators. In this work, impedance matching between the TENG and EMG is achieved facilely through commercial transformers, and we put forward a highly integrated hybrid device. The rotating-sleeve triboelectric-electromagnetic hybrid nanogenerator (RSHG) is designed by simulating the structure of a common EMG, which ensures a high efficiency in transferring ambient mechanical energy into electric power. The RSHG presents an excellent performance with a short-circuit current of 1 mA and open-circuit voltage of 48 V at a rotation speed of 250 rpm. Systematic measurements demonstrate that the hybrid nanogenerator can deliver the largest output power of 13 mW at a loading resistance of 8 kΩ. Moreover, it is demonstrated that a wind-driven RSHG can light dozens of light-emitting diodes and power an electric watch. The distinctive structure and high output performance promise the practical application of this rotating-sleeve structured hybrid nanogenerator for large-scale energy conversion.

  20. The success of sleeve gastrectomy in the management of metabolic syndrome and obesity

    OpenAIRE

    Shabbir, Asim; Dargan, Dallan

    2014-01-01

    Abstract The rapid reversal of diabetes, hypertension, hyperlipidaemia and obesity by surgical means has challenged accepted doctrines regarding the management of metabolic syndrome. Sleeve gastrectomy, which developed initially as a preparatory procedure for biliopancreatic diversion with duodenal switch, has seen an exponential rise in popularity as an effective lone laparoscopic bariatric procedure. Superior excess weight loss, a low complication rate, and excellent food tolerance, combine...

  1. Axillary artery injury after an anterior shoulder fracture dislocation and “periosteal sleeve avulsion of the rotator cuff” (SARC. Case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Ash Chehata

    2017-04-01

    Full Text Available We present the rare complication of an axillary artery injury associated with an anterior dislocation of the humerus and what we believe to be the first reported periosteal sleeve avulsion of the entire rotator cuff (SARC. We review the literature and discuss the cause of this unusual injury pattern. Keywords: Axillary artery, Shoulder fracture dislocation, Periosteal sleeve avulsion, SARC

  2. Sleeve gastrectomy leads to easy management of hormone replacement therapy and good weight loss in patients treated for craniopharyngioma.

    Science.gov (United States)

    Trotta, Manuela; Da Broi, Joël; Salerno, Angelo; Testa, Rosa M; Marinari, Giuseppe M

    2017-03-01

    The aim of this study is to investigate the effects of sleeve gastrectomy on hormone replacement therapy and on hypothalamic obesity in patients affected by craniopharyngioma with post-surgical pan-hypopituitarism. A retrospective review of three patients, treated for hypothalamic obesity with laparoscopic sleeve gastrectomy, who have previously undergone surgery for craniopharyngioma in their childhood, was done. Patients' mean age and BMI were 22.3 years (range 21-24) and 49.2 kg/m 2 (range 41.6-58.1), respectively. The mean time of delay between neurosurgery and bariatric surgery was 12.3 years (range 6-16). There were no major complications or deaths. At 24 months follow-up, the mean BMI was 35.3 kg/m 2 (range 31.2-40.6). No hydrocortisone and sex steroids dose changes were observed, while levothyroxine was decreased in two patients. Growth hormone replacement therapy was increased in two patients, whereas it was started in one patient. Desmopressin was significantly decreased in all of them. Patients with surgically induced pan-hypopituitarism after craniopharyngioma who become obese, can expect good results from sleeve gastrectomy: this procedure does not have significant negative effects on hormone substitution and leads to a good stabilization of body weight in a mid-term follow-up.

  3. Three-Dimensional Bio-Printed Scaffold Sleeves With Mesenchymal Stem Cells for Enhancement of Tendon-to-Bone Healing in Anterior Cruciate Ligament Reconstruction Using Soft-Tissue Tendon Graft.

    Science.gov (United States)

    Park, Sin Hyung; Choi, Yeong-Jin; Moon, Sang Won; Lee, Byung Hoon; Shim, Jin-Hyung; Cho, Dong-Woo; Wang, Joon Ho

    2018-01-01

    To investigate the efficacy of the insertion of 3-dimensional (3D) bio-printed scaffold sleeves seeded with mesenchymal stem cells (MSCs) to enhance osteointegration between the tendon and tunnel bone in anterior cruciate ligament (ACL) reconstruction in a rabbit model. Scaffold sleeves were fabricated by 3D bio-printing. Before ACL reconstruction, MSCs were seeded into the scaffold sleeves. ACL reconstruction with hamstring tendon was performed on both legs of 15 adult rabbits (aged 12 weeks). We implanted 15 bone tunnels with scaffold sleeves with MSCs and implanted another 15 bone tunnels with scaffold sleeves without MSCs before passing the graft. The specimens were harvested at 4, 8, and 12 weeks. H&E staining, immunohistochemical staining of type II collagen, and micro-computed tomography of the tunnel cross-sectional area were evaluated. Histologic assessment was conducted with a histologic scoring system. In the histologic assessment, a smooth bone-to-tendon transition through broad fibrocartilage formation was identified in the treatment group, and the interface zone showed abundant type II collagen production on immunohistochemical staining. Bone-tendon healing histologic scores were significantly higher in the treatment group than in the control group at all time points. Micro-computed tomography at 12 weeks showed smaller tibial (control, 9.4 ± 0.9 mm 2 ; treatment, 5.8 ± 2.9 mm 2 ; P = .044) and femoral (control, 9.6 ± 2.9 mm 2 ; treatment, 6.0 ± 1.0 mm 2 ; P = .03) bone-tunnel areas in the treated group than in the control group. The 3D bio-printed scaffold sleeve with MSCs exhibited excellent results in osteointegration enhancement between the tendon and tunnel bone in ACL reconstruction in a rabbit model. If secure biological healing between the tendon graft and tunnel bone can be induced in the early postoperative period, earlier, more successful rehabilitation may be facilitated. Three-dimensional bio-printed scaffold sleeves with

  4. Thermoelastic/plastic analysis of waste-container sleeve: III. Influence of salt strength on sleeve loading. Technical memorandum report (RSI-0018)

    International Nuclear Information System (INIS)

    Pariseau, W.G.

    1975-01-01

    Three combinations of salt tensile, compressive and shear strength in linear and nonlinear yield conditions used in the axially symmetric, large displacement thermoelastic/plastic waste-container/sleeve loading estimates show no influence on the analysis. The salt remains elastic throughout the excavation and subsequent 10 year heating period. Tensile stresses are not observed, tensile strength is thus not important to the analysis even at 10 percent of the compressive strength value. Although strictly applicable only to the conditions of the analyses reported here, the capability for incorporating arbitrary strength combinations in linear or non-linear yield conditions is demonstrated. Computer plots of principal stresses and displacement fields at various stages of the excavation and heating simulation aid in the visualization of repository concept mechanics and show the possible need for additional mesh refinement for more precise stress information

  5. DURABILITY-RELATED CHARACTERISTICS OF DOUBLE-LAYER STRUCTURES OF PIPELINES CONNECTED TO POLYMERIC SLEEVES

    Directory of Open Access Journals (Sweden)

    Orlov Vladimir Alexandrovich

    2012-10-01

    The ultimate objective of the software programme is to assess the applicability of the trenchless repair method involving a polymeric sleeve in each specific case by taking account of the environment and the condition of the pipeline. The software is also capable of developing the requirements to be fulfilled by subcontractors in order to assure the appropriate quality of any repair work performed and the reliability of any pipeline sections repaired.

  6. Enabling recruitment success in bariatric surgical trials: pilot phase of the By-Band-Sleeve study.

    Science.gov (United States)

    Paramasivan, S; Rogers, C A; Welbourn, R; Byrne, J P; Salter, N; Mahon, D; Noble, H; Kelly, J; Mazza, G; Whybrow, P; Andrews, R C; Wilson, C; Blazeby, J M; Donovan, J L

    2017-11-01

    Randomized controlled trials (RCTs) involving surgical procedures are challenging for recruitment and infrequent in the specialty of bariatrics. The pilot phase of the By-Band-Sleeve study (gastric bypass versus gastric band versus sleeve gastrectomy) provided the opportunity for an investigation of recruitment using a qualitative research integrated in trials (QuinteT) recruitment intervention (QRI). The QRI investigated recruitment in two centers in the pilot phase comparing bypass and banding, through the analysis of 12 in-depth staff interviews, 84 audio recordings of patient consultations, 19 non-participant observations of consultations and patient screening data. QRI findings were developed into a plan of action and fed back to centers to improve information provision and recruitment organization. Recruitment proved to be extremely difficult with only two patients recruited during the first 2 months. The pivotal issue in Center A was that an effective and established clinical service could not easily adapt to the needs of the RCT. There was little scope to present RCT details or ensure efficient eligibility assessment, and recruiters struggled to convey equipoise. Following presentation of QRI findings, recruitment in Center A increased from 9% in the first 2 months (2/22) to 40% (26/65) in the 4 months thereafter. Center B, commencing recruitment 3 months after Center A, learnt from the emerging issues in Center A and set up a special clinic for trial recruitment. The trial successfully completed pilot recruitment and progressed to the main phase across 11 centers. The QRI identified key issues that enabled the integration of the trial into the clinical setting. This contributed to successful recruitment in the By-Band-Sleeve trial-currently the largest in bariatric practice-and offers opportunities to optimize recruitment in other trials in bariatrics.

  7. Effects of sleeve gastrectomy in neonatally streptozotocin-induced diabetic rats.

    Directory of Open Access Journals (Sweden)

    Yan Wang

    Full Text Available BACKGROUND: Sleeve gastrectomy (SG has emerged recently as a stand-alone bariatric procedure to treat morbid obesity and enhance glucose homeostasis. The aim of the study was to evaluate its effects in neonatally streptozotocin (STZ-induced diabetic rats (n-STZ diabetic rats. METHODOLOGY AND PRINCIPAL FINDINGS: To induce diabetes, STZ (90 mg/kg was administered intraperitoneally to 2-day-old male pups. When 12 weeks old, diabetic rats were randomized into sleeve operation group (SLG, n = 6 and sham operation group (SOG, n = 6. Body weights were monitored weekly, and daily consumption of water and food were followed for eight consecutive weeks postoperatively. Serum glucose levels were measured periodically at the 4th and 8th week after surgery. Insulin, ghrelin, glucose-dependent insulinotropic polypeptide (GIP and Glucagon-like peptide-1 (GLP-1 levels were assayed at the end of the study. Our data showed that SLG rats exhibited significantly lower body weight gain in addition to reduced food and water intakes postoperatively compared to their sham-operation counterparts. However, resolution of diabetes was not observed in our study. Correspondingly, there were no significant differences between SOG rats and SLG rats in glucose metabolism-associated hormones, including insulin, GIP and GLP-1. In contrast, ghrelin level significantly decreased (P<0.01 in SLG group (58.01 ± 3.75 pg/ml after SG surgery compared to SOG group (76.36 ± 3.51 pg/ml. CONCLUSIONS: These observations strongly suggest that SG is effective in controlling body weight. However, SG did not achieve resolution or improvement of diabetes in n-STZ diabetic rats.

  8. Banding the Sleeve Improves Weight Loss in Midterm Follow-up.

    Science.gov (United States)

    Fink, Jodok M; Hoffmann, Natalie; Kuesters, Simon; Seifert, Gabriel; Laessle, Claudia; Glatz, Torben; Hopt, Ulrich T; Konrad Karcz, W; Marjanovic, Goran

    2017-04-01

    Laparoscopic sleeve gastrectomy (LSG) can achieve excellent weight loss, yet sleeve dilatation with concomitant weight regain proves to be a relevant issue. Hence, additional restriction might improve results after LSG. In a retrospective matched-pair analysis, 42 patients who underwent banded LSG (BLSG) using a MiniMizer® ring between January 2012 and October 2014 were analysed regarding weight loss, complications and comorbidity. Median follow-up was 3 years. Forty-two patients who had undergone conventional LSG were selected as matched pairs. Mean preoperative BMI was 54.93 ± 7.42 kg/m 2 for BLSG and 53.46 ± 6.69 kg/m 2 for LSG (Mann-Whitney P = 0.540). Total weight loss (%TWL) was significantly greater in the BLSG group 3 years after surgery (BLSG 38.22% ± 7.26; n = 26 vs. LSG 32.69 ± 9.47; n = 26; P = 0.0154). Ring placement had no relevant impact on new-onset reflux (Fisher's exact test P = 1.0) but a tendency towards reflux improvement when reflux pre-existed (odds ratio 1.96). The major side effect of ring implantation was regurgitation with over 44% of patients presenting with regurgitation >1 per week (Fisher's exact test P = 0.0019, odds ratio 18.07). BLSG is a safe procedure showing similar comorbidity to conventional LSG. However, BLSG leads to a higher rate of postoperative regurgitation. Weight loss is significantly improved 3 years after surgery. Hence, additional ring implantation might be an option for increased restriction in LSG surgery.

  9. Alternative design of pipe sleeve for liquid removal mechanism in mortar slab layer

    Science.gov (United States)

    Nazri, W. M. H. Wan; Anting, N.; Lim, A. J. M. S.; Prasetijo, J.; Shahidan, S.; Din, M. F. Md; Anuar, M. A. Mohd

    2017-11-01

    Porosity is one of the mortar’s characteristics that can cause problems, especially in the room space that used high amount of water, such as bathrooms. Waterproofing is one of the technology that normally used to minimize this problem which is preventing deep penetration of liquid water or moisture into underlying concrete layers. However, without the proper mechanism to remove liquid water and moisture from mortar system, waterproofing layer tends to be damaged after a long period of time by the static formation of liquid water and moisture at mortar layer. Thus, a solution has been proposed to drain out water that penetrated into the mortar layer. This paper introduces a new solution using a Modified Pipe Sleeve (MPS) that installed at the mortar layer. The MPS has been designed considering the percentage surface area of the pipe sleeve that having contact with mortar layer (2%, 4%, 6%, 8% and 10%) with angle of holes of 60°. Infiltration test and flow rate test have been conducted to identify the effectiveness of the MPS in order to drain out liquid water or moisture from the mortar layer. In this study shows that, MPS surface area 10%, angled 60°, function effectively as a water removal compared to other design.

  10. Synthesis and electrochemical performances of ZnO/MnO2 sea urchin-like sleeve array as anode materials for lithium-ion batteries

    International Nuclear Information System (INIS)

    Fang, J.; Yuan, Y.F.; Wang, L.K.; Ni, H.L.; Zhu, H.L.; Yang, J.L.; Gui, J.S.; Chen, Y.B.; Guo, S.Y.

    2013-01-01

    MnO 2 is electrodeposited onto ZnO nanorod array grown on Ni foil, forming a binder-free ZnO/MnO 2 composited electrode. XRD, EDS, SEM and TEM are used to analyze the phase and microstructure of this composite. Burr-like MnO 2 nanoflakes grows on ZnO nanorod array, the top of the composite is hollow and at the bottom exists ZnO large block core as an internal support, forming ZnO/MnO 2 sea urchin-like sleeve array. As anode material for lithium ion batteries, ZnO/MnO 2 sleeve array exhibits higher discharge capacity and coulombic efficiency, better rate performance and cycling stability than single ZnO nanorod array or directly electrodepsited MnO 2 , and the composite effect is very remarkable. After 100 cycles, the discharge capacity of ZnO/MnO 2 still reaches 1259 mA h g −1 , and coulombic efficiency surpasses 98%, higher than those of ZnO nanorod array (111 mA h g −1 ) and directly electrodeposited MnO 2 (507 mA h g −1 ). The improvement of the electrochemical performances is due to the unique sea urchin-like sleeve array architecture. MnO 2 burr tube shell structure leads to high electrochemical activity while the internal ZnO core support ensures good structure stability. The gradually opening of sea urchin-like sleeve during the cycling further enhances the electrochemical activity of MnO 2 , stabilizing and increasing electrochemical performances of the ZnO/MnO 2 composite

  11. CT-Guided Percutaneous Drainage of Infected Collections Due to Gastric Leak After Sleeve Gastrectomy for Morbid Obesity: Initial Experience

    International Nuclear Information System (INIS)

    Kelogrigoris, M.; Sotiropoulou, E.; Stathopoulos, K.; Georgiadou, V.; Philippousis, P.; Thanos, L.

    2011-01-01

    This study was designed to evaluate the efficacy and safety of computed tomography (CT)-guided drainage in treating infected collections due to gastric leak after laparoscopic sleeve gastrectomy for morbid obesity. From January 2007 to June 2009, 21 patients (9 men and 12 women; mean age, 39.2 (range, 26–52) years) with infected collections due to gastric leak after laparoscopic sleeve gastrectomy for morbid obesity underwent image-guided percutaneous drainage. All procedures were performed using CT guidance and 8- to 12-Fr pigtail drainage catheters. Immediate technical success was achieved in all 21 infected collections. In 18 of 21 collections, we obtained progressive shrinkage of the collection with consequent clinical success (success rate 86%). In three cases, the abdominal fluid collection was not resolved, and the patients were reoperated. Among the 18 patients who avoided surgery, 2 needed replacement of the catheter due to obstruction. No major complications occurred during the procedure. The results of our study support that CT-guided percutaneous drainage is an effective and safe method to treat infected abdominal fluid collections due to gastric leak in patients who had previously underwent laparoscopic sleeve gastrectomy for morbid obesity. It may be considered both as a preparatory step for surgery and a valuable alternative to open surgery. Failure of the procedure does not, however, preclude a subsequent surgical operation.

  12. The impact of selected factors on parameters of weight loss after sleeve gastrectomy.

    Science.gov (United States)

    Binda, Artur; Jaworski, Paweł; Kudlicka, Emilia; Ciesielski, Adam; Cabaj, Hubert; Tarnowski, Wiesław

    2016-01-01

    The effectiveness of sleeve gastrectomy has been confirmed in many studies. The impact of individual factors on the parameters of weight loss is still not clear. To identify important factors affecting the parameters of weight loss after sleeve gastrectomy. The impact of prognostic factors and postoperative care components on body mass index (BMI) and percentage excess weight loss (%EWL) was assessed in a group of 100 consecutive patients who underwent laparoscopic sleeve gastrectomy. The baseline BMI and body mass in patients with BMI < 30 kg/m 2 and BMI ≥ 30 kg/m 2 12 months after surgery were, respectively, 39.7 ±3.2 vs. 45.9 ±4.6 kg/m 2 , p < 0.0001, and 114.4 ±16.8 vs. 130.3 ±18.5 kg, p < 0.0001. In the group with EWL < 50%, the average age was 47.1 ±7.7 vs. 40.6 ±10.8 in the group with EWL ≥ 50%, p = 0.0025. In the group of patients with preoperative weight loss, %EWL was 61.4 ±17.2 vs. 53.3 ±19.3% in the group with no weight loss, p = 0.0496. Body mass index of the patients who started physical activities was 30.6 ±4.2 kg/m 2 vs. 34.0 ±5.6 kg/m 2 in the patients with no physical activity, p = 0.0013, and %EWL was 63.4 ±14.6 vs. 47.0 ±19.9%, p < 0.0001, respectively. In the case of patients regularly consulted by a dietician BMI was 30.6 ±4.2 kg/m 2 vs. 35.1 ±5.5 kg/m 2 in the group without systematic consultations, p < 0.0001, and %EWL was 63.1 ±15.1% vs. 42.3 ±18.2%, p < 0.0001. Lower baseline body weight parameters, younger age, preoperative weight loss, starting systematic physical activities and constant care of a dietician were conducive to achieving better results of surgery, as assessed on the basis of changes in BMI and %EWL.

  13. Stapling and Section of the Nasogastric Tube during Sleeve Gastrectomy: How to Prevent and Recover

    Directory of Open Access Journals (Sweden)

    A. Péquignot

    2011-07-01

    Full Text Available Bariatric surgery has become an integral part of morbid obesity treatment with well-defined indications. Some complications, specific or not, due to laparoscopic sleeve gastrectomy (LSG procedure have recently been described. We report a rare complication unpublished to date: a nasogastric section during great gastric curve stapling. A 44-year-old woman suffered of severe obesity (BMI 36.6 kg/m2 with failure of medical treatments for years. According to already published technique, a LSG was performed. Six hours postoperatively, a nurse removed the nasogastric tube according to the local protocol and the nasogastric tube was abnormally short, with staples at its extremity. Surgery was performed with peroperative endoscopy. In conclusion, this is the first publication of a nasogastric section during LSG. Therefore we report this case and propose a solution to prevent its occurrence. To avoid this kind of accident, we now systematically insert the nasogastric tube by mouth through a Guedel cannula. Then, to insert the calibrating bougie, we entirely withdraw the nasogastric tube.

  14. FXR is a molecular target for the effects of vertical sleeve gastrectomy

    DEFF Research Database (Denmark)

    Ryan, Karen K; Tremaroli, Valentina; Clemmensen, Christoffer

    2014-01-01

    Bariatric surgical procedures, such as vertical sleeve gastrectomy (VSG), are at present the most effective therapy for the treatment of obesity, and are associated with considerable improvements in co-morbidities, including type-2 diabetes mellitus. The underlying molecular mechanisms contributing......-X receptor, also known as NR1H4). We therefore examined the results of VSG surgery applied to mice with diet-induced obesity and targeted genetic disruption of FXR. Here we demonstrate that the therapeutic value of VSG does not result from mechanical restriction imposed by a smaller stomach. Rather, VSG...

  15. Comparison of Early Results and Complications between Multi-and Single-Port Sleeve Gastrectomy: A Randomized Clinical Study

    Directory of Open Access Journals (Sweden)

    Seyed Vahid Hosseini

    2017-05-01

    Full Text Available Background: In recent years, laparoscopic sleeve gastrectomy (LSG has become more acceptable for obese patients. Single-port sleeve gastrectomy (SPSG is more popular since each abdominal incision carries the risk of bleeding, hernia, and internal organ injury as well as exponentially affecting cosmesis. This cross-sectional study aimed at comparing multi-port sleeve gastrectomy (MPSG and SPSG in terms of their early results and complications. Methods: Out of129 obese patients candidated for LSG, 102 patients were assigned to 2 groups of SPSG and MPSG. Complications and demographic data such as body mass index (BMI, age, gender, operation time, and hospital stay were measured. All surgeries were carried out between2013 and 2015 in Shiraz, Iran. Data analysis was performed using SPSS, version 16 for Windows (SPSS Inc., Chicago, IL. The continuous and categorical variables were compared using the Student t-test and the Chi-square test or the Fisher exact test, respectively. Results: The patients’ data from both groups were similar in terms of age, intraoperative and postoperative bleeding volume, and length of hospital stay. Mean BMI was 42.8±0.7 in the SPSG group and 45.3±1.2 in the MPSG group. Duration of surgery was significantly lower in the SPSG group (P<0.001. Only 1 patient from the SPSG group and 5 patients from the MPSG group had bleeding as an early complication. Conclusion: The differences in each complication between the groups were not statistically significant. SPSG seems to be safe and is the same as MPSG in terms of major postoperative complications. Trial Registration Number: IRCT201512229936N12

  16. Weight loss independent changes in adipose tissue macrophage and T cell populations after sleeve gastrectomy in mice

    Directory of Open Access Journals (Sweden)

    Henriette Frikke-Schmidt

    2017-04-01

    Full Text Available Objective: In addition to adipocytes, adipose tissue contains large numbers of immune cells. A wide range of evidence links the activity of these cells to regulation of adipocyte and systemic metabolic function. Bariatric surgery improves several aspects of metabolic derangements and at least some of these effects occur in a weight-loss independent manner. We sought to investigate the impact of vertical sleeve gastrectomy (VSG on adipose immune cell frequencies. Methods: We analyzed the frequencies of immune cells within distinct adipose tissue depots in obese mice that had VSG or sham surgery with a portion of the latter group pair-fed such that their body mass was matched to the VSG animals. Results: We demonstrate that VSG induced a shift in the epididymal adipose tissue leukocyte profile including increased frequencies of CD11c− macrophages, increased frequencies of T cells (CD4+, CD8+, and CD4−/CD8− T cells all increased, but a significantly decreased frequency of adipose tissue dendritic cells (ATDC that, despite the continued high fat feeding of the VSG group, dropped below control diet levels. Conclusions: These results indicate that VSG induces substantial changes in the immune populations residing in the adipose depots independent of weight loss. Author Video: Author Video Watch what authors say about their articles Keywords: Sleeve gastrectomy, Adipose tissue, Macrophages, T cells, Dendritic cells, Abbreviations: ATDC, adipose tissue dendritic cell, ATM, adipose tissue macrophage, eWAT, epididymal white adipose tissue, FFA, free fatty acids, HFS, high fat sham, iWAT, inguinal white adipose tissue, SVC, stromal vascular cells, VSG, vertical sleeve gastrectomy

  17. Laparoscopic sleeve gastrectomy in patients over 59 years: early recovery and 12-month follow-up.

    Science.gov (United States)

    Leivonen, Marja Kaarina; Juuti, Anne; Jaser, Nabil; Mustonen, Harri

    2011-08-01

    Bariatric surgery has shown to be safe for patients over 60 years with good results especially considering resolving of comorbidities. Sleeve gastrectomy is considered to be safer than gastric bypass (GBP) and more effective than gastric banding with less adverse symptoms. Weight loss may be more modest than after GBP, but the effect on vitamins may also be milder. Since 2007, we collected prospectively 12-month follow-up data from 55 sleeve gastrectomy patients of whom 12 were over 59 years of age. Vitamin and calcium supplements were used postoperatively. The recovery from the operation was recorded during hospital stay, at 1- and 12-month follow-up visits using a standard protocol including laboratory tests. The results between patients over and under 59 years were compared. The preoperative weight and weight loss were comparable between the groups. Operation time was shorter and hospital stay was longer for older patients, p = ns. There was no operative mortality. Early major complications were seen more often in the older age group, 42% vs 9% (p = 0.02), but late complications were more common in younger patients, 17% vs 44%, p = ns. Early complications were mostly bleedings, which did not lengthen the hospital stay, neither were re-operations nor endoscopic procedures needed. Excess weight loss and resolving of comorbidities after 12 months was comparable between the groups. However, vitamin deficiencies and hypoalbuminemia were more common in the older age group, 42% and 23% for vitamins and 44% and 29% for proteins, p = ns. The older patients had more adverse effects related to surgery, 25% vs 9%, and younger had more adverse psychiatric effects, p = ns. Sleeve gastrectomy is effective and safe for older bariatric patients. Weight loss is comparable to younger patients and enough to resolve the comorbidities in most of the patients. With standardized nutritional supplementation, the older patients had more often vitamin deficiencies and

  18. Design of a drying system for a rollover carwash machine using CFD

    Directory of Open Access Journals (Sweden)

    Seyyed M.M. Sabet

    2016-10-01

    Full Text Available This work describes the design and development of a new drying system for a rollover carwash machine with the support of numerical tools. The drying system is composed of a pair of stationary vertical dryers and a moveable horizontal dryer that can adjust itself to the contour of a vehicle. After the definition of the dryers’ concept, their performance was assessed individually to check their internal flow pattern and to improve their airflow distribution. These issues are expected to provide feedback on redesign and geometric optimization of the dryers. After redesign of the dryers separately, the behaviour of the complete drying system was studied on actual vehicle models, representative of the shortest and tallest dimensions that can be washed with the existing carwash machine sector. The drying efficiency of the whole system was studied by calculation of shear stress distribution on various surfaces of a given vehicle. The results allowed concluding that the overall drying performance of the design system is very good and assure adequate drying on most vehicles surfaces. The results obtained from numerical studies were then validated with experimental measurements and a good agreement was found between the two. The procedure employed in this work can be applied to support the design and analysis of other mechanical drying systems.

  19. Prevalence of Non-Alcoholic Fatty Liver Disease in Morbidly Obese Patients Undergoing Sleeve Bariatric Surgery in Iran and Association With Other Comorbid Conditions

    Directory of Open Access Journals (Sweden)

    Karimi-Sari

    2015-04-01

    Full Text Available Background Nonalcoholic fatty liver disease (NAFLD is one of the most common causes of chronic liver disease including simple steatosis to nonalcoholic steatohepatitis (NASH. NASH could progress to cirrhosis and liver cancer. The prevalence of NAFLD is increasing by increasing the prevalence of obesity. Objectives This study was designed to determine the prevalence of NASH in morbidly obese patients undergoing sleeve bariatric surgery and its correlation with other comorbidities. Patients and Methods In this analytical cross-sectional study, 114 morbidly obese patients undergoing sleeve gastrectomy were selected. Liver ultrasonography was performed for all patients before surgery and NAFLD existence and its grade was determined by hyperechoic texture and fatty infiltration. The liver enzymes and lipid profile were also measured. Prevalence of NAFLD in these patients and its correlation with other comorbid conditions (e.g. diabetes mellitus, hyperlipidemia, hypertension, hypothyroidism and ischemic heart disease were evaluated by SPSS software version 18. Results One hundred fourteen patients with a mean age of 33.96 ± 9.92 years and mean BMI of 43.61 ± 5.77 kg/m2 were enrolled (48 males and 66 females. The prevalence of NAFLD was 16.7%. NAFLD existence was associated with systolic blood pressure, hyperlipidemia, hemoglobin, hematocrit, triglyceride, alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase and potassium (P < 0.05. Conclusions According to high prevalence of NAFLD in morbidly obese patients undergoing sleeve gastrectomy in Iran, we suggest using gold standard diagnostic method to determine the exact NAFLD prevalence and evaluation of impact of sleeve surgery on NAFLD in short and long term follow-up periods.

  20. Calf Compression Sleeves Change Biomechanics but Not Performance and Physiological Responses in Trail Running

    Directory of Open Access Journals (Sweden)

    Hugo A. Kerhervé

    2017-04-01

    Full Text Available Introduction: The aim of this study was to determine whether calf compression sleeves (CS affects physiological and biomechanical parameters, exercise performance, and perceived sensations of muscle fatigue, pain and soreness during prolonged (~2 h 30 min outdoor trail running.Methods: Fourteen healthy trained males took part in a randomized, cross-over study consisting in two identical 24-km trail running sessions (each including one bout of running at constant rate on moderately flat terrain, and one period of all-out running on hilly terrain wearing either degressive CS (23 ± 2 mmHg or control sleeves (CON, <4 mmHg. Running time, heart rate and muscle oxygenation of the medial gastrocnemius muscle (measured using portable near-infrared spectroscopy were monitored continuously. Muscle functional capabilities (power, stiffness were determined using 20 s of maximal hopping before and after both sessions. Running biomechanics (kinematics, vertical and leg stiffness were determined at 12 km·h−1 at the beginning, during, and at the end of both sessions. Exercise-induced Achilles tendon pain and delayed onset calf muscles soreness (DOMS were assessed using visual analog scales.Results: Muscle oxygenation increased significantly in CS compared to CON at baseline and immediately after exercise (p < 0.05, without any difference in deoxygenation kinetics during the run, and without any significant change in run times. Wearing CS was associated with (i higher aerial time and leg stiffness in running at constant rate, (ii with lower ground contact time, higher leg stiffness, and higher vertical stiffness in all-out running, and (iii with lower ground contact time in hopping. Significant DOMS were induced in both CS and CON (>6 on a 10-cm scale with no difference between conditions. However, Achilles tendon pain was significantly lower after the trial in CS than CON (p < 0.05.Discussion: Calf compression did not modify muscle oxygenation during ~2 h 30

  1. Novel technique for airless connection of artificial heart to vascular conduits.

    Science.gov (United States)

    Karimov, Jamshid H; Gao, Shengqiang; Dessoffy, Raymond; Sunagawa, Gengo; Sinkewich, Martin; Grady, Patrick; Sale, Shiva; Moazami, Nader; Fukamachi, Kiyotaka

    2017-12-01

    Successful implantation of a total artificial heart relies on multiple standardized procedures, primarily the resection of the native heart, and exacting preparation of the atrial and vascular conduits for pump implant and activation. Achieving secure pump connections to inflow/outflow conduits is critical to a successful outcome. During the connection process, however, air may be introduced into the circulation, traveling to the brain and multiple organs. Such air emboli block blood flow to these areas and are detrimental to long-term survival. A correctly managed pump-to-conduit connection prevents air from collecting in the pump and conduits. To further optimize pump-connection techniques, we have developed a novel connecting sleeve that enables airless connection of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) to the conduits. In this brief report, we describe the connecting sleeve design and our initial results from two acute in vivo implantations using a scaled-down version of the CFTAH.

  2. Report covering examination of parts from downhole steam generators. [Combustor head and sleeve parts

    Energy Technology Data Exchange (ETDEWEB)

    Pettit, F. S.; Meier, G. H.

    1983-08-01

    Combustor head and sleeve parts were examined by using optical and scanning electron metallography after use in oxygen/diesel and air/diesel downhole steam generators. The degradation of the different alloy components is described in terms of reactions with oxygen, sulfur and carbon in the presence of cyclic stresses, all generated by the combustion process. Recommendations are presented for component materials (alloys and coatings) to extend component lives in the downhole steam generators. 9 references, 22 figures, 3 tables.

  3. Esophagogastric pathology in morbid obese patient: preoperative diagnosis and influence in the selection of surgical technique

    Directory of Open Access Journals (Sweden)

    Sergio Estévez-Fernández

    2015-07-01

    Full Text Available Introduction: Given the difficulty in accessing to the excluded stomach after gastric bypass and the increase in gastroesophageal reflux after sleeve gastrectomy, it is justified to perform a preoperative fibrogastroscopy. The influence of the fibrogastroscopy (FGS findings in the therapeutic approach is analyzed. Patients and methods: A retrospective study of preoperative FGS findings is performed, from 04/06 to 12/12. The influence of the FGS results on the surgical technique selection, in the endoscopic or medical treatment and its relation to gastric fistula is analyzed by means of multivariate regression (confounding factors: Age, body mass index, arterial hypertension, diabetes mellitus, antiplatelet therapy, surgical technique (bariatric surgery, sleeve gastrectomy. Results: Three hundred thirty one patients are included: 32.6% biopsy of gastric lesion; 27% gastritis; 18.1% hiatal hernia; 3% metaplasia; 0.6% Barrett esophagus; 2.1% esophagitis; 0.3% dysplasia; 0.3 Schatzky's ring; 1.5% incompetent cardia; 2.4% duodenitis; 0.3% gastric erosions; 0.6% gastric xanthoma; 1.8%, gastric polyp; 1.6% duodenal ulcer; 0.6% papulo-erosive gastritis; 0.6% esophageal papilloma; 0.3% submucosal tumor. Helicobacter pylori+ 30.2% (triple therapy eradication in all patients. The FGS findings led to a variation in the surgical technique or to the completion of endoscopic treatment in 22.2% of cases. The gastric lesions did not influence the development of gastric fistula. Independent prognostic factors of fistula: Sleeve gastrectomy (7.9% vs. 2.7%; p = 0.02; OR: 1.38 IC95: 1.01-1.87 and the body mass index > 50 kg/m² (6.7% vs. 2.2%; p = 0.04; OR: 3.7 IC95: 1.12-12.4. Conclusions: The diagnosis of gastroesophageal disease through preoperative FGS motivated variations in the therapeutic approach in 52% of patients, so we consider essential to include the preoperative FGS in bariatric surgery.

  4. Portomesenteric Vein Thrombosis After Laparoscopic Sleeve Gastrectomy: Incidence, Analysis and Follow-Up in 1236 Consecutive Cases

    OpenAIRE

    Villagr?n, Rodrigo; Smith, Gabriela; Rodriguez, Walter; Flores, Carlos; Cariaga, Mario; Araya, Sof?a; Ya?ez, Marisol; Fuentes, Paulina; Linares, Jeannette; Zapata, Antonio

    2016-01-01

    Background Portomesenteric vein thrombosis (PMVT) is a rare but severe complication after laparoscopic bariatric surgery, with potentially serious consequences. We aimed to describe the incidence, clinical features, management, outcome, and midterm follow-up in patients with PMVT after laparoscopic sleeve gastrectomy (LSG). Methods This retrospective and descriptive study included patients who underwent LSG between November 2009 and July 2015 and developed PMVT. The following data were analyz...

  5. Residual curarization and postoperative respiratory complications following laparoscopic sleeve gastrectomy. The effect of reversal agents: sugammadex vs. neostigmine

    Directory of Open Access Journals (Sweden)

    Ezri Tiberiu

    2015-04-01

    Full Text Available Background: Incomplete muscle relaxant reversal or re-curarization may be associated with postoperative respiratory complications. In this retrospective study we compared the incidence of postoperative residual curarization and respiratory complications in association with the type of muscle relaxant reversal agent, sugammadex or neostigmine, in patients undergoing laparoscopic sleeve gastrectomy.

  6. Perioperative analgesic requirements in severely obese adolescents and young adults undergoing laparoscopic versus robotic-assisted gastric sleeve resection

    Directory of Open Access Journals (Sweden)

    Anita Joselyn

    2015-01-01

    Full Text Available Purpose: One of the major advantages for patients undergoing minimally invasive surgery as compared to an open surgical procedure is the improved recovery profile and decreased opioid requirements in the perioperative period. There are no definitive studies comparing the analgesic requirements in patients undergoing two different types of minimally invasive procedure. This study retrospectively compares the perioperative analgesic requirements in severely obese adolescents and young adults undergoing laparoscopic versus robotic-assisted, laparoscopic gastric sleeve resection. Materials and Methods: With Institutional Review Board approval, the medication administration records of all severely obese patients who underwent gastric sleeve resection were retrospectively reviewed. Intra-operative analgesic and adjuvant medications administered, postoperative analgesic requirements, and visual analog pain scores were compared between those undergoing a laparoscopic procedure versus a robotic-assisted procedure. Results: This study cohort included a total of 28 patients who underwent gastric sleeve resection surgery with 14 patients in the laparoscopic group and 14 patients in the robotic-assisted group. Intra-operative adjuvant administration of both intravenous acetaminophen and ketorolac was similar in both groups. Patients in the robotic-assisted group required significantly less opioid during the intra-operative period as compared to patients in the laparoscopic group (0.15 ± 0.08 mg/kg vs. 0.19 ± 0.06 mg/kg morphine, P = 0.024. Cumulative opioid requirements for the first 72 postoperative h were similar in both the groups (0.64 ± 0.25 vs. 0.68 ± 0.27 mg/kg morphine, P = NS. No difference was noted in the postoperative pain scores. Conclusion: Although intraoperative opioid administration was lower in the robotic-assisted group, the postoperative opioid requirements, and the postoperative pain scores were similar in both groups.

  7. The effect of knee brace and knee sleeve on the proprioception of the knee in young non-professional healthy sportsmen.

    Science.gov (United States)

    Bottoni, G; Herten, A; Kofler, P; Hasler, M; Nachbauer, W

    2013-12-01

    Proprioception has been defined as the capacity to feel the position of a joint in space as sensed by the central nervous system. Prophylactic knee braces are supposed to help in knee injury prevention not just with a mechanical support of the joint but also improving proprioception. The main aim of this study was to determine the effects of a knee brace and a knee sleeve on knee proprioception. The secondary aim was to determine if different starting angles of the knee and different movement directions influence knee proprioception. We tested a group of twenty healthy male sport students without knee injuries. They were tested with the brace, with the sleeve and without support. The threshold of detection of passive knee movement with a starting knee angle of 30° and 60°, both in flexion and extension was determined. We did not find any statistically significant change in the threshold of detection of passive knee movement wearing the brace or the sleeve compared to the unsupported condition (p=0.462, α=0.05). We found a significantly lower proprioceptive sensitivity starting at the more flexed knee angle (p=0.005, α=0.05) and moving in extension than in the other test situations (p=0.001, α=0.05). Movement direction and starting position appear to influence the threshold of detection of passive knee movement. The results of this study also suggest that knee supports do not influence either positively or negatively knee proprioception of uninjured active subjects. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Gastritis in patients undergoing sleeve gastrectomy: Prevalence, ethnic distribution, and impact on glycemic.

    Science.gov (United States)

    Rath-Wolfson, Lea; Varona, Roy; Bubis, Golan; Tatarov, Alexander; Koren, Rumelia; Ram, Edward

    2017-04-01

    Laparoscopic sleeve gastrectomy (LSG) is a therapeutic option in severely obese patients. The aim of this study was to evaluate the presence of Helicobacter pylori (HP) gastritis and non-Helicobacter gastritis in the gastrectomy specimens, and its association to other variables.One hundred six sleeve gastrectomy specimens were examined histopathologically for the presence of gastritis and its relation to other factors like ethnicity, glycemic control, and postoperative complications.Twelve patients had HP gastritis, 39 had non-HP gastritis, and 55 had normal mucosa. There was a statistical difference between the Arab and Jewish Israeli patients in our study. Twenty-eight of the Arab patients had HP gastritis and 48% had non-HP gastritis. In the Jewish population 6% had HP gastritis and 34% had non-HP gastritis. The preoperative glycemic control was worse in the gastritis group with a mean HbA1c of 8.344% while in the normal mucosa group the mean HbA1c was 6.55. After operation the glycemic control reverted to normal in most the diabetic patients. There were few postoperative complications however, they were not related to HP.There is a high incidence of gastritis in obese patients. The incidence of gastritis in the Arab population in our study was higher than that in the Jewish population. The glycemic control before surgery was worse in patients with gastritis than in the normal mucosa group. HP bares no risk for postoperative complications after LSG and does not affect weight loss. However a larger cohort of patients must be studied to arrive at conclusive results.

  9. A multicenter study of routine versus selective intraoperative leak testing for sleeve gastrectomy.

    Science.gov (United States)

    Bingham, Jason; Kaufman, Jedediah; Hata, Kai; Dickerson, James; Beekley, Alec; Wisbach, Gordon; Swann, Jacob; Ahnfeldt, Eric; Hawkins, Devon; Choi, Yong; Lim, Robert; Martin, Matthew

    2017-09-01

    Staple line leaks after sleeve gastrectomy are dreaded complications. Many surgeons routinely perform an intraoperative leak test (IOLT) despite little evidence to validate the reliability, clinical benefit, and safety of this procedure. To determine the efficacy of IOLT and if routine use has any benefit over selective use. Eight teaching hospitals, including private, university, and military facilities. A multicenter, retrospective analysis over a 5-year period. The efficacy of the IOLT for identifying unsuspected staple line defects and for predicting postoperative leaks was evaluated. An anonymous survey was also collected reflecting surgeons' practices and beliefs regarding IOLT. From January 2010 through December 2014, 4284 patients underwent sleeve gastrectomy. Of these, 37 patients (.9%) developed a postoperative leak, and 2376 patients (55%) received an IOLT. Only 2 patients (0.08%) had a positive finding. Subsequently, 21 patients with a negative IOLT developed a leak. IOLT demonstrated a sensitivity of only 8.7%. There was a nonsignificant trend toward increased leak rates when an IOLT was performed versus when IOLT was not performed. Leak rates were not statistically different between centers that routinely perform IOLT versus those that selectively perform IOLT. Routine IOLT had very poor sensitivity and was negative in 91% of patients who later developed postoperative leaks. The use of IOLT was not associated with a decrease in the incidence of postoperative leaks, and routine IOLT had no benefit over selective leak testing. IOLT should not be used as a quality indicator or "best practice" for bariatric surgery. Published by Elsevier Inc.

  10. Design optimization of a robust sleeve antenna for hepatic microwave ablation

    International Nuclear Information System (INIS)

    Prakash, Punit; Webster, John G; Deng Geng; Converse, Mark C; Mahvi, David M; Ferris, Michael C

    2008-01-01

    We describe the application of a Bayesian variable-number sample-path (VNSP) optimization algorithm to yield a robust design for a floating sleeve antenna for hepatic microwave ablation. Finite element models are used to generate the electromagnetic (EM) field and thermal distribution in liver given a particular design. Dielectric properties of the tissue are assumed to vary within ± 10% of average properties to simulate the variation among individuals. The Bayesian VNSP algorithm yields an optimal design that is a 14.3% improvement over the original design and is more robust in terms of lesion size, shape and efficiency. Moreover, the Bayesian VNSP algorithm finds an optimal solution saving 68.2% simulation of the evaluations compared to the standard sample-path optimization method

  11. Validation of sleeve of straight union type B for leaks

    Energy Technology Data Exchange (ETDEWEB)

    Teutonico, Mauricio; Fazzini, Pablo [Gie S.A., Buenos Aires (Argentina)

    2009-07-01

    Analytic study and experimental validation of type B sleeve with overlapping, were done in order to determine whether they are suitable for used as permanent leaks repair in hydrocarbons transport lines. All relevant background of this type of repair was analyzed, following the guidelines defined by applicable regulations (ASME B31.8 and ASME B31.4) and modeled by finite elements methods. Solicitations under internal pressure of each one of the reinforcement parts were analyzed. All solicitations involved in welded unions were studied, so as the reinforcement effectiveness when it is filled with internal gap filler. Experimental tests were developed, consisted on the reinforcement installation upon damaged pipes and the following hydrostatic test. These tests were assisted by a digitalized measurement, to determine the solicitations at different parts of the reinforcement; strain gauges were used for this task. (author)

  12. Health-Related Fitness Improvements in Morbid Obese Patients After Laparoscopic Sleeve Gastrectomy: a Cohort Study.

    Science.gov (United States)

    Gallart-Aragón, Tania; Fernández-Lao, Carolina; Castro-Martín, Eduardo; Cantarero-Villanueva, Irene; Cózar-Ibáñez, Antonio; Arroyo-Morales, Manuel

    2017-05-01

    Laparoscopic sleeve gastrectomy (LSG) has demonstrated high long-term effectiveness and major advantages over other techniques. The objective of this study was to analyze changes in physical fitness parameters in morbidly obese patients during 6 months after LSG. We conducted a descriptive observational study with 6-month follow-up in 72 LSG patients, evaluating changes in body mass index (BMI), functional capacity (6-min walking test), hand grip strength (manual dynamometry), flexibility (fingertip-to-floor test), balance (Flamingo test), physical activity level (International Physical Activity Questionnaire, IPAQ), and perception of general physical fitness (International Fitness Scale [IFIS] questionnaire). The ANOVA revealed significant improvements in BMI, functional capacity, flexibility, balance, and physical activity level (P fitness in most cases. No significant changes were found in dominant hand (P = 0.676) or non-dominant hand (P = 0.222) dynamometry. General physical fitness was positively correlated with BMI and distance in the 6-min test, and was negatively correlated with fingertip-to-floor distance. Morbidly obese patients showed major improvements at 6 months after LSG in functional capacity, balance, mobility, and physical activity, with no change in grip strength. These improvements were related to a better self-perception of general physical fitness.

  13. Aspects of supersymmetric inflation

    International Nuclear Information System (INIS)

    Lindblom, P.R.

    1987-01-01

    A new supersymmetric inflationary model is presented and shown to possess the following features: a successful slow rollover produced by quantum corrections; an acceptable pattern of supersymmetry breaking leading to the correct value of the electroweak scale; and a stable slow rollover transition to a minimum with vanishing cosmological constant. It is demonstrated that there is a class of GUT models which are compatible with an inflationary universe scenario in which: (a) the GUT and inflationary phase transitions are distinct (as in supersymmetric inflation); and (b) an observable number of GUT monopoles are created thermally due to reheating of the GUT sector after inflation. This provides one of the few ways of reconciling an observation of GUT monopoles with inflation. New techniques are developed for constructing inflationary models with multiple inflation fields, such as generalizing the one-dimensional slow rollover constraints and estimating the contribution to δρ/ρ from fluctuations transverse to the path of the slow rollover. A new method for ending the slow rollover portion of the inflationary transition is developed

  14. Rollover Car Crashes with Ejection: A Deadly Combination—An Analysis of 719 Patients

    Directory of Open Access Journals (Sweden)

    Rifat Latifi

    2014-01-01

    Full Text Available Rollover car crashes (ROCs are serious public safety concerns worldwide. Objective. To determine the incidence and outcomes of ROCs with or without ejection of occupants in the State of Qatar. Methods. A retrospective study of all patients involved in ROCs admitted to Level I trauma center in Qatar (2011-2012. Patients were divided into Group I (ROC with ejection and Group II (ROC without ejection. Results. A total of 719 patients were evaluated (237 in Group I and 482 in Group II. The mean age in Group I was lower than in Group II (24.3±10.3 versus 29±12.2; P=0.001. Group I had higher injury severity score and sustained significantly more head, chest, and abdominal injuries in comparison to Group II. The mortality rate was higher in Group I (25% versus 7%; P=0.001. Group I patients required higher ICU admission rate (P=0.001. Patients in Group I had a 5-fold increased risk for age-adjusted mortality (OR 5.43; 95% CI 3.11–9.49, P=0.001. Conclusion. ROCs with ejection are associated with higher rate of morbidity and mortality compared to ROCs without ejection. As an increased number of young Qatari males sustain ROCs with ejection, these findings highlight the need for research-based injury prevention initiatives in the country.

  15. [Laparoscopic gastric sleeve in gastric volvulus secondary to diaphragmatic eventration in an adult patient].

    Science.gov (United States)

    Gálvez-Valdovinos, Ramiro; Marín-Santillán, Ernesto; Funes-Rodríguez, Juan Francisco; López-Ambriz, Gustavo

    2016-01-01

    Acute gastric volvulus is a rare, but potentially life-threatening, cause of upper gastrointestinal obstruction. Male of 60 years old with severe epigastric pain and abdominal distension with haematemesis on two occasions. The patient was haemodynamically stable, with abdominal distension and palpable epigastric fullness. Hematic cytology showed: haemoglobin 8.2g/dl and haematocrit 27%. Abdominal X-ray showed an elevation of left diaphragm with a hugely dilated stomach. A nasogastric tube was inserted. Endoscopy was performed. There was no active bleeding, but it was impossible to reach the duodenum due to the stomach distortion. The upper gastrointestinal X-ray study showed the appearance of an inverted stomach in the chest and an organoaxial gastric torsion. The CT scans of thorax and abdomen showed a gastric ascent into the thoracic cavity. Laparoscopic surgery was performed, finding the left hemi-diaphragm elevated, and the stomach, splenic angle of the colon, the spleen and tail of the pancreas were also raised. A linear gastrectomy (gastric sleeve) was performed. The postoperative progress was satisfactory. Oral feeding was started 72 hours after surgery, and the patient was discharged, and has remained asymptomatic during the following by 8 years. Emergency physicians must maintain a high level of suspicion in patients that present with signs and symptoms suggesting upper digestive tract occlusion. The gastric sleeve is an excellent alternative to avoid recurrence of gastric volvulus. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  16. Achalasia: A case report on its effect during surgical decision making for laparoscopic sleeve gastrectomy in the young morbidly obese patient

    Directory of Open Access Journals (Sweden)

    Rodolfo J. Oviedo, MD, FACS

    2016-01-01

    Conclusion: The patient has already undergone a POEM procedure, which was chosen to maintain the gastric fundus, cardia, and gastroesophageal junction (GEJ architecture as opposed to a LHM with Dor fundoplication, which would have altered the anatomy, thus making a concomitant laparoscopic sleeve gastrectomy an unfeasible option.

  17. Evaluation of nutrient status after laparoscopic sleeve gastrectomy 1, 3, and 5 years after surgery.

    Science.gov (United States)

    Saif, Taha; Strain, Gladys W; Dakin, Gregory; Gagner, Michel; Costa, Ricardo; Pomp, Alfons

    2012-01-01

    Laparoscopic sleeve gastrectomy evolved as a primary bariatric procedure with little information on its nutritional effects. Our objective was to assess the longer term micronutrient and vitamin status after laparoscopic sleeve gastrectomy at a university hospital. Measurements of ferritin, iron, total iron binding capacity, hemoglobin, hematocrit, parathyroid hormone, albumin, calcium, magnesium, phosphorus, zinc, folate, and vitamins A, B1, B12, and D were obtained at baseline and 1, 3, and 5 years after surgery. Two-sample t tests with multiple adjusted comparisons and Fisher's exact test were used to determine deficiency. A total of 82 patients (67% women), with a mean age of 46.4 years and a baseline body mass index 55.7 kg/m2 were included in the present study (35 at 1, 27 at 3, and 30 at 5 years postoperatively). The percentage of excess body mass index loss was 58.5% at year 1 in 35 patients, 63.1% at year 3 in 27 patients, and 46.1% at year 5 in 30 patients. The parathyroid hormone level decreased from 75.0 to 49.6 ng/mL in year 1 to 40.7 ng/mL in year 3. The year 5 levels increased to 99.6 ng/mL. The mean vitamin D level increased from 23.6 ng/mL to 35.0, 32.1 and 34.8 at years 1, 3, and 5 (P = .05 for baseline to year 1). The vitamin D level was less than normal in 42% of the patients at year 5. After normalization from baseline, by year 5, parathyroid hormone had increased in 58.3% of patients. At year 5, vitamin B1 was less than normal in 30.8% of patients, and hemoglobin and hematocrit were less than normal in for 28.6% and 25% of patients, respectively. Finally, 28.9% of patients reported taking supplements in year 1, 42.9% in year 3, and 63.3% in year 5. The other variables were not significantly different. Laparoscopic sleeve gastrectomy resulted in health improvements through year 3. At year 5, the nutrient levels had reverted toward the baseline values. These observations provide focus for necessary clinical monitoring. Copyright © 2012 American

  18. Evaluation of an inductively-coupled plasma with an extended-sleeve torch as an atomization cell for laser-excited fluorescence spectrometry.

    Science.gov (United States)

    Kosinski, M A; Uchida, H; Winefordner, J D

    1983-05-01

    An inductively-coupled plasma (ICP) with an extended-sleeve torch has been evaluated as an atomization cell for laser-excited fluorescence spectrometry. Limits of detection for 20 lines are given. The detection power is almost equivalent to that obtained by excitation with a hollow-cathode lamp. Interelement effects and spectral interferences are discussed.

  19. Numerical Analysis and Experimental Study of Hard Roofs in Fully Mechanized Mining Faces under Sleeve Fracturing

    Directory of Open Access Journals (Sweden)

    Zhitao Zheng

    2015-11-01

    Full Text Available Sudden falls of large-area hard roofs in a mined area release a large amount of elastic energy, generate dynamic loads, and cause disasters such as impact ground pressure and gas outbursts. To address these problems, in this study, the sleeve fracturing method (SFM was applied to weaken a hard roof. The numerical simulation software FLAC3D was used to develop three models based on an analysis of the SFM working mechanism. These models were applied to an analysis of the fracturing effects of various factors such as the borehole diameter, hole spacing, and sleeve pressure. Finally, the results of a simulation were validated using experiments with similar models. Our research indicated the following: (1 The crack propagation directions in the models were affected by the maximum principal stress and hole spacing. When the borehole diameter was fixed, the fracturing pressure increased with increasing hole spacing. In contrast, when the fracturing pressure was fixed, the fracturing range increased with increasing borehole diameter; (2 The most ideal fracturing effect was found at a fracturing pressure of 17.6 MPa in the model with a borehole diameter of 40 mm and hole spacing of 400 mm. The results showed that it is possible to regulate the falls of hard roofs using the SFM. This research may provide a theoretical basis for controlling hard roofs in mining.

  20. Laparoscopic sleeve gastrectomy achieves substantial weight loss in an adolescent girl with morbid obesity.

    Science.gov (United States)

    Till, H K-H; Muensterer, O; Keller, A; Körner, A; Blueher, S; Merkle, R; Kiess, W

    2008-02-01

    The European guidelines for bariatric surgery clearly define criteria for operating children with morbid obesity. However the appropriate technique for this age-group has not been identified yet. So far gastric banding and Roux-Y bypass represent the standards, but they demand life-long tolerance of either an artificial device or significant malabsorption. Although laparoscopic sleeve gastrectomy (LSG) demands neither, it has not been advocated for this age-group as a stand-alone technique. We report the outcome and the rationale for this approach in a 16-year-old girl with morbid obesity. The patient had been in an intensive weight loss programme for several years, but within the last 12 months her body weight had increased again dramatically. At referral she presented with a body mass index (BMI) of 43.1 kg/m(2) (height 169 cm, preoperative weight 121 kg) and suffered from co-morbidities as features of a developing metabolic-vascular syndrome such as dyslipidemia and arterial hypertension. Our obesity team and her parents opted for surgery at that time. The patient underwent LSG with a 5-trocar technique. With a gastroscope protecting the lesser curvature, the stomach was resected from the antrum to the fundus using an EndoGIA stapler. The operative time was 95 minutes, there were no perioperative complications and the patient was extubated immediately. An upper GI contrast study on postoperative day 4 showed a tubular gastric remnant with a volume of about 200 ml. The patient's diet was advanced as tolerated to full oral intake, and she was followed-up regularly in our special obesity outpatient clinic. After 12 months she had lost 36 kg (BMI 29 kg/m(2)) and enjoyed sports and activities with friends again. Laboratory studies ruled out malnutrition or vitamin deficiency. LSG is a safe and effective option for bariatric surgery in obese adolescents. It can be offered as a stand-alone restrictive operation and could be extended to a malabsorptive procedure at any

  1. Analysis and application of GEWI sleeve weld-ability (Material: C45)

    International Nuclear Information System (INIS)

    Zhang Weiming; Zhang Hongliu

    2010-01-01

    Welding may use two kinds of welding process of shielded metal arc welding and CO 2 shielded arc welding between inner ring in nuclear island steel lining (material: P265GH) and GEWI sleeve (material:C45).CO 2 shielded arc welding is often used because of higher welding efficiency, in particular, in condition of plan press, but quality can come into being some problems if we lack strict measures, for example welding procedure. Shielded metal arc welding control easier quality, but welding efficiency is lower. Comparing and analyzing Weld-ability of C45(Medium carbon Quenched and Tempered Steel.) between of shielded metal arc welding and CO 2 shielded arc welding, suggest to use shielded metal arc welding in project practice, and control strict welding procedure measure of pre-heating treatment and Post-heating. (authors)

  2. Heat transfer analysis of the waste-container sleeve/salt configuration

    International Nuclear Information System (INIS)

    Callahan, G.D.; Ratigan, J.L.; Russell, J.E.; Fossum, A.F.

    1975-01-01

    Prior to this investigation, the heat transport considered was only that of straight conduction. The waste container, air gap, and sleeve arrangement was considered to be a single, consistent, time-dependent, heat-generating unit in intimate contact with the salt. The conduction model does not accurately model the heat transfer mechanisms available. Thus radiation and combined radiation and convection must also be considered in the determination of the temperature field. As would be expected, the canister temperatures are higher for the case of radiation across the airgap than those that result from conduction when the canister is in intimate contact with the salt. For the radiation case, the canister temperatures rise rapidly to a temperature of approximately 1,140 0 F and maintain an almost steady state condition for one year whereafter the temperatures slowly decrease. The far field temperatures, near the pillar centerline, are essentially equivalent for all cases. As time proceeds, the far field temperatures of the conduction models are about 15% different

  3. TAPIR, Thermal Analysis of HTGR with Graphite Sleeve Fuel Elements

    International Nuclear Information System (INIS)

    Weicht, U.; Mueller, W.

    1983-01-01

    1 - Nature of the physical problem solved: Thermal analysis of a reactor core containing internally and/or externally gas cooled prismatic fuel elements of various geometries, rating, power distribution, and material properties. 2 - Method of solution: A fuel element in this programme is regarded as a sector of a fuelled annulus with graphite sleeves of any shape on either side and optional annular gaps between fuel and graphite and/or within the graphite. It may have any centre angle and the fuelled annulus may become a solid cylindrical rod. Heat generation in the fuel is assumed to be uniform over the cross section and peripheral heat flux into adjacent sectors is ignored. Fuel elements and coolant channels are treated separately, then linked together to fit a specified pattern. 3 - Restrictions on the complexity of the problem: Maxima of: 50 fuel elements; 50 cooled channels; 25 fuel geometries; 25 coolant channel geometries; 10 axial power distributions; 10 graphite conductivities

  4. Development of a New Technique for Reconstruction of Hepatic Artery during Liver Transplantation in Sprague-Dawley Rat.

    Directory of Open Access Journals (Sweden)

    Xingmu Liu

    Full Text Available Sleeve anastomosis is the most common technique used to rearterialize orthotopic liver transplants (OLT. However, this technique has a number of disadvantages, including difficulty of performance of the technique visually unaided. We herein describe a novel rearterialized OLT model in the rat.Forty-six male Sprague Dawley rats (300-400 g were used as donors and recipients. Based on Kamada's cuff technique, the new model involved performing a modified "sleeve" anastomosis between the celiac trunk of the donor and common hepatic artery of the recipient to reconstruct blood flow to the hepatic artery. An additional ten male Sprague Dawley rats underwent liver transplantation without artery reconstruction. Liver grafts were retrieved from the two groups and histological examination was performed following surgery.Total mean operating times were ~42 minutes for the donor liver extraction and 57 minutes for the recipient transplantation. Graft preparation took an additional 15 minutes and the time to fix the arterial bracket was ~3 minutes. During transplantation, the anhepatic phase lasted 18 ± 2.5 min and the artery reconstruction only required ~3 minutes. The patency rate was 94.44% and the 4-week survival rate was 90%. Histology indicated obvious fibrosis in the liver grafts without artery reconstruction, while normal histology was observed in the arterialized graft.This new method allows for the surgical procedure to be performed visually unaided with good survival and patency rates and represents an alternative model investigating OLT in rats.

  5. Rare Neurological Complications After Sleeve Gastrectomy.

    Science.gov (United States)

    Tabbara, Malek; Carandina, Sergio; Bossi, Manuela; Polliand, Claude; Genser, Laurent; Barrat, Christophe

    2016-12-01

    Bariatric surgery is considered to be the most effective treatment of morbid obesity and improvement of obesity-related comorbidities, such as type II diabetes. However, both peripheral and central neurological complications can occur after bariatric surgery. Such complications tend to occur more frequently after bypass surgery than after sleeve gastrectomy (SG). The objective of this study was to identify the patients that presented post-operative neurological complications after undergoing SG and describe the incidence, presentation, and management of these complications. This was a retrospective study of 592 cases of SG performed between 2009 and 2014 with a special focus on patients who presented neurological complications. Of the 592 SG cases, only seven (1.18 %) patients presented neurological complications. All patients had uneventful post-operative course, but all reported feeding difficulties, accompanied by severe dysphagia, and rapid weight loss, with a mean weight loss of 35 kg (30-40 kg) 3 months after SG. All patients were readmitted owing to neurological symptoms that included paresthesia, abolition of deep tendon reflexes of the lower limbs, muscle pain, and motor and sensitive deficits in some cases. There were two cases of Wernicke's encephalopathy. All patients were treated for neuropathy secondary to vitamin B1 deficiency and had a significant improvement and/or resolution of their symptoms. Neurological complications after SG are rare and are often preceded by gastrointestinal symptoms, rapid weight loss, and lack of post-operative vitamin supplementation. Re-hospitalization and multidisciplinary team management are crucial to establish the diagnosis and initiate treatment.

  6. Impact of laparoscopic sleeve gastrectomy on body mass index, ghrelin, insulin and lipid levels in 100 obese patients

    OpenAIRE

    Hady, Hady Razak; Dadan, Jacek; Go?aszewski, Pawe?; Safiejko, Kamil

    2012-01-01

    Introduction A high percentage of patients benefit from bariatric procedures in terms of metabolic effect and substantial body mass reduction. These procedures improve glucose metabolism leading to the amelioration or complete resolution of type 2 diabetes, reduction of insulin resistance and alleviation of metabolic syndrome effects. Aim To assess the impact of laparoscopic sleeve gastrectomy (LSG) on the plasma levels of ghrelin, insulin, glucose, triglycerides, total cholesterol, high-dens...

  7. Gastric wall thickness and stapling in laparoscopic sleeve gastrectomy - a literature review.

    Science.gov (United States)

    Barski, Krzysztof; Binda, Artur; Kudlicka, Emilia; Jaworski, Paweł; Tarnowski, Wiesław

    2018-03-01

    Despite the growing experience of bariatric surgeons in performing laparoscopic sleeve gastrectomy, the number of complications involving staple line leaks remains constant. Hence a solution to avoid such complications is still sought. A defect of the staple line may be the consequence of an inappropriate choice of staple size in relation to gastric wall thickness. Due to the variable nature of gastric wall thickness, the choice of proper staple height is not obvious. In the few studies in which gastric wall thickness was measured, it was observed to decrease gradually from the antrum to the fundus. However, the authors are divided on the issue of whether gender and body mass index influence gastric wall thickness. The question whether there are other perioperative factors that would allow gastric wall thickness to be predicted remains unanswered.

  8. Sweet Eating Habit: Does This Affect the Results After Sleeve Gastrectomy?

    Science.gov (United States)

    Moser, Federico; Marconetto, Mariana; Gorodner, Verónica; Viscido, Germán; Piazzoni, Noel; Maldonado, Pablo; Rodriguez, Eugenia Loretani; Obeide, Lucio

    2016-04-01

    It is commonly believed that eating habits, specially the sweet eating habit, can predict results after bariatric surgery; for this reason, it is considered one of the selection criteria when deciding the surgical technique. However, there is not enough evidence of its impact on the results after sleeve gastrectomy (SG). To evaluate the relationship between the sweet eating habit and weight loss after SG. Cross-sectional retrospective study. Group A: nonobese subjects, and group B: patients who underwent SG and had ≥6 months follow-up. Demographics, anthropometrics, percentage excess weight loss (%EWL) at 6, 12, and 24 months, and eating habits before surgery were analyzed. Sweet eating consumption was classified as follows: mild, moderate, and severe. Uni- and bivariate logistic regression analysis according to each variable was performed. Between 2006 and 2011, 157 patients underwent SG at our institution; 36% were male, age 41 years old, and initial body mass index 46 kg/m(2). Mean %EWL at 6, 12, and 24 months was 66%, 77%, and 70%, respectively. Sweet eating consumption: Mild: 59%; Moderate: 38%; and Severe: 3%. No difference was found in sweet eating patterns among groups A and B; %EWL for mild, moderate, and severe sweet eaters at 6 months was 66 ± 16, 66 ± 14, and 65 ± 10, respectively (P = non-significant [NS]). The same analysis was made at 12 months: 76 ± 20, 79 ± 18, and 78 ± 11 (P = NS). At 24 months, only mild and moderate sweet eaters were available for comparison: 69 ± 23 and 73 ± 19, respectively (P = NS). Preliminary data suggested that preoperative sweet eating habit would not predict results after SG in terms of weight loss.

  9. Pattern of changes in quality of life of obese patients after sleeve gastrectomy in Sulaimani provence –Kurdistan-Iraq, based on 4 years experience in two bariatric centers

    Directory of Open Access Journals (Sweden)

    Hiwa Omer Ahmed

    2018-02-01

    Full Text Available Background: Obesity influences all aspects of the life of obese patients physically, psychologically, socially and monetarily, it is not only a disease but rather a beginning point of a group of ailments and inabilities, which gradually impacts and changes all aspects of their life. Objectives: The changes in the Quality of life in respect to the amount of access weight lost after sleeve gastrectomy. Patients, materials and methods: A prospective longitudinal study evaluating 40 female patients who underwent laparoscopic sleeve gastrectomy within 4 years, starting from July 4th, 2012 up to July 5th, 2016. Results: More than three-quarter of the patients were not satisfied with their body before their operation, but six to twelve months after their weight loss; (N = 36, 90% of them were satisfied with their new body image. Half of the patients were unhappy before their operation, but twelve months later (N = 31, 77.5% of them became much happier. Regarding satisfaction with the body image, noticeable improvement occurred since (N = 36, 90% of them were satisfied with their new body image. While, most of them have had low self-esteem and (N 27, 67.5% of the patients had no self-esteem at all, 12 months after the operation (N = 35, 87.5% felt great improvement in their self-esteem (p-value = .040. A significant decrease in appetite was noticed in (N = 39, 97.5% of the patients after 12 months. Conclusion: Significant changes in the parallel pattern to the extent of EWL were noticed in the quality of life of morbidly obese patients after laparoscopic sleeve gastrectomy. Keywords: A pattern, Parallel, Reverse-pattern, Laparoscopic sleeve gastrectomy, Quality of life, Non-health quality of life, Morbid obesity

  10. Numerical and Experimental Study of Producing Flanges on Hollow Parts by Extrusion with a Movable Sleeve / Badania Teoretyczno-Doświadczalne Procesu Wyciskania Z Zastosowaniem Ruchomej Tulei Kołnierza We Wsadach Drążonych

    Directory of Open Access Journals (Sweden)

    Gontarz A.

    2015-12-01

    Full Text Available The paper presents the numerical and experimental results of a new method for producing flanges on hollow parts. With this new method, the flange is extruded by a movable sleeve. This innovative technique is modelled numerically by the finite element method. The effect of workpiece and finished product geometries on the forming process is investigated and failure modes are identfied. The numerical reults are then verified in experiments. The tests are conducted using a three-slide forging press equipped with a special device. The numerical and experimental results show a good agreement, which proves that the developed method is correct.

  11. Effect of Bariatric Sleeve Gastrectomy Technique on Women’s Lower Urinary Tract Symptoms and Quality of Life: A Prospective Study

    Directory of Open Access Journals (Sweden)

    Fatih Uruç

    2016-09-01

    Full Text Available Objective Obesity triggers lower urinary tract symptoms (LUTS secondary to accumulation of excess fat which may lead to increase in intra-abdominal/intravesical pressures and subsequent impairment in pelvic floor muscles. However, it is considered that weight loss resolve these symptoms. In this study, we aimed to investigate the effects of bariatric surgery and especially Sleeve gastrectomy (SG on women’s LUTS, and quality of life. Materials and Methods A total of 53 patients who have undergone laparoscopic SG in our clinics between April 2014 and March 2015 were included in this prospective study. Age, body weight and body mass index (BMI of the participants were preoperatively and postoperatively recorded. The patients have pre/post-operatively filled the Beck depression inventory (BDI, International prostate symptom score (IPSS, International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF and the 36-Item Short Form health survey (SF-36 scores were recorded. Additionally, post-operative decrease in body weight and BMI of the patients was recorded. Results There was a statistically significant decrease in mean BDI, IPSS and ICIQ-SF scores and SF-36 (prominent increment in physical and mental component summary (PCS and MCS scores, when compared with pre-operative values. A positive correlation was found between BMI and parameters including age, BDI and IPSS. However, no significant correlation was present between BMI and the parameters including ICIQ-SF, PCS and MCS. Conclusion Negative effect of obesity on LUTS and quality of life cannot be ignored. We assume that bariatric surgery can induce dramatic weight loss, amelioration in symptoms of urinary dysfunction and increase in quality of life of women.

  12. Repair technology for steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Ho; Jung, Hyun Kyu; Jung, Seung Ho; Kim, Chang Hoi; Jung, Young Moo; Seo, Yong Chil; Kim, Jung Su; Seo, Moo Hong

    2001-02-01

    The most commonly used sleeving materials are thermally treated Alloy 600 and thermally treated Alloy 690 Alloy. Currently, thermally treated Alloy 690 and Alloy 800 are being offered although Alloy 800 has not been licensed in the US. To install sleeve, joint strength, leak tightness, PWSCC resistance, evaluation on process parameter range and the effect of equipments and procedures on repair plan and radiation damage have to be investigated before sleeving. ABB CE provides three type of leak tight Alloy 690 TIG welded and PLUSS sleeve. Currently, Direct Tube Repair technique using Nd:YAG laser has been developed by ABB CE and Westinghouse. FTI has brazed and kinetic sleeve designs for recirculating steam generator and hydraulic and rolled sleeve designs for one-through steam generators. Westinghouse provides HEJ, brazed and laser welded sleeve design. When sleeve is installed in order to repair the damaged S/G tubes, it is certain that defects can be occurred due to the plastic induced stress and thermal stress. Therefore it is important to minimize the residual stress. FTI provides the electrosleeve technique as a future repair candidate using electroplating.

  13. Repair technology for steam generator tubes

    International Nuclear Information System (INIS)

    Kim, Seung Ho; Jung, Hyun Kyu; Jung, Seung Ho; Kim, Chang Hoi; Jung, Young Moo; Seo, Yong Chil; Kim, Jung Su; Seo, Moo Hong

    2001-02-01

    The most commonly used sleeving materials are thermally treated Alloy 600 and thermally treated Alloy 690 Alloy. Currently, thermally treated Alloy 690 and Alloy 800 are being offered although Alloy 800 has not been licensed in the US. To install sleeve, joint strength, leak tightness, PWSCC resistance, evaluation on process parameter range and the effect of equipments and procedures on repair plan and radiation damage have to be investigated before sleeving. ABB CE provides three type of leak tight Alloy 690 TIG welded and PLUSS sleeve. Currently, Direct Tube Repair technique using Nd:YAG laser has been developed by ABB CE and Westinghouse. FTI has brazed and kinetic sleeve designs for recirculating steam generator and hydraulic and rolled sleeve designs for one-through steam generators. Westinghouse provides HEJ, brazed and laser welded sleeve design. When sleeve is installed in order to repair the damaged S/G tubes, it is certain that defects can be occurred due to the plastic induced stress and thermal stress. Therefore it is important to minimize the residual stress. FTI provides the electrosleeve technique as a future repair candidate using electroplating

  14. Endoscopic sleeve gastroplasty: the learning curve.

    Science.gov (United States)

    Hill, Christine; El Zein, Mohamad; Agnihotri, Abhishek; Dunlap, Margo; Chang, Angela; Agrawal, Alison; Barola, Sindhu; Ngamruengphong, Saowanee; Chen, Yen-I; Kalloo, Anthony N; Khashab, Mouen A; Kumbhari, Vivek

    2017-09-01

     Endoscopic sleeve gastroplasty (ESG) is gaining traction as a minimally invasive bariatric treatment. Concern that the learning curve may be slow, even among those proficient in endoscopic suturing, is a barrier to widespread implementation of the procedure. Therefore, we aimed to define the learning curve for ESG in a single endoscopist experienced in endoscopic suturing who participated in a 1-day ESG training program.  Consecutive patients who underwent ESG between February 2016 and November 2016 were included. The performing endoscopist, who is proficient in endoscopic suturing for non-ESG procedures, participated in a 1-day ESG training session before offering ESG to patients. The outcome measurements were length of procedure (LOP) and number of plications per procedure. Nonlinear regression was used to determine the learning plateau and calculate the learning rate.  Twenty-one consecutive patients (8 males), with mean age 47.7 ± 11.2 years and mean body mass index 41.8 ± 8.5 kg/m 2 underwent ESG. LOP decreased significantly across consecutive procedures, with a learning plateau at 101.5 minutes and a learning rate of 7 cases ( P  = 0.04). The number of plications per procedure also decreased significantly across consecutive procedures, with a plateau at 8 sutures and a learning rate of 9 cases ( P  < 0.001). Further, the average time per plication decreased significantly with consecutive procedures, reaching a plateau at 9 procedures ( P  < 0.001).  Endoscopists experienced in endoscopic suturing are expected to achieve a reduction in LOP and number of plications per procedure in successive cases, with progress plateauing at 7 and 9 cases, respectively.

  15. Long-term nutritional impact of sleeve gastrectomy.

    Science.gov (United States)

    Caron, M; Hould, F S; Lescelleur, O; Marceau, S; Lebel, S; Julien, F; Simard, S; Biertho, Laurent

    2017-10-01

    Sleeve gastrectomy (SG) has become a predominant bariatric procedure throughout the world. However, the long-term nutritional impact of this procedure is unknown. To describe the nutritional deficiencies before and after SG and to analyze the influence of baseline weight on nutritional status. University-affiliated tertiary care center. All patients who underwent SG as a standalone procedure between 2008 and 2012 were included in this study. Patients were given multivitamin supplementation. Data were obtained from our prospectively maintained electronic database and are reported as mean ± standard deviation and percentage. Bivariate analyses were conducted to evaluate the influence of selected variables on outcomes. The mean age of the 537 patients was 48.0 ± 11.3 years, with an initial body mass index of 48.1 ± 8.7 kg/m 2 . Excess weight loss and total weight loss were 56.2% and 28.0% at 1 year and 43.0% and 21.1% at 5 years, respectively (Pvitamin B12 in 30.3% and 16.4% (Pvitamin D 63.2% and 24.3% (Pvitamin A insufficiency peaked from 7.9% preoperatively to 28.7% at 3 months (Pvitamin B12 and vitamin D. Nutritional deficiencies are common in patients with morbid obesity before and after surgery. Preoperative supplementation and long-term nutritional follow-up are required to prevent nutritional deficiencies. Copyright © 2017 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  16. Self-Regulation of Weight After Sleeve Gastrectomy.

    Science.gov (United States)

    Madeira, Teresa; do Carmo, Isabel; Bicha Castelo, Henrique; Santos, Osvaldo

    2018-03-01

    Bariatric surgery is recognized as the most effective method for achieving relevant weight loss in subjects with severe obesity. However, there is insufficient knowledge about weight self-regulation and quality of motivation in these patients. The main goal of this study was to characterize the association between the percentage of excess weight loss (%EWL) and the motivation to manage weight, at least 1 year after sleeve gastrectomy (SG). This is an observational longitudinal retrospective study. All patients corresponding to predefined inclusion criteria who underwent SG from January 2008 to July 2010 at a main general hospital were invited. A version of the Treatment Self-Regulation Questionnaire (TSRQ) was used to assess patients' quality of motivation: TSRQ concerning continuing the weight self-management program. Clinical data were collected from patients' records. Overall, 81 patients participated (16 men and 65 women, 25-64 years old). The average body mass index was significantly reduced from 45.3 ± 7.0 kg/m 2 preoperatively to 32.7 ± 6.9 kg/m 2 postoperatively. Autonomous self-regulation was higher than externally controlled self-regulation, regarding motives to keep managing weight after SG. Postoperatively, %EWL correlated negatively with external self-regulation. SG was found to be associated with the quality of motivation for losing weight. External motivations were associated with worse results. These findings support the importance of multiprofessional teams in the assessment and treatment of patients, aiming for the promotion of weight self-regulation after bariatric surgery.

  17. Anorectal function following colo-anal sleeve anastomosis for chronic radiation injury to the rectum

    Energy Technology Data Exchange (ETDEWEB)

    Varma, J S; Smith, A N

    1986-04-01

    This paper reports the results of anorectal manometry and electrophysiological studies of the pelvic floor in eight patients who had undergone anterior resection of the rectum with mucosal proctectomy and colo-anal sleeve anastomosis for radiation rectal injury. The group comprised six women and two men (age range 61-84 years, mean 71 years). Six bladder carcinoma patients had received small field (10 x 10 cm) external beam radiotherapy (5500 cGy in 20 treatments over 4 weeks); two cervical cancer patients had been given whole pelvis, external beam radiotherapy supplemented by a single caesium implant (cumulative dosage of 9500 cGy to the vaginal vault, equivalent to 7500 cG to point A).

  18. Anorectal function following colo-anal sleeve anastomosis for chronic radiation injury to the rectum

    International Nuclear Information System (INIS)

    Varma, J.S.; Smith, A.N.

    1986-01-01

    This paper reports the results of anorectal manometry and electrophysiological studies of the pelvic floor in eight patients who had undergone anterior resection of the rectum with mucosal proctectomy and colo-anal sleeve anastomosis for radiation rectal injury. The group comprised six women and two men (age range 61-84 years, mean 71 years). Six bladder carcinoma patients had received small field (10 x 10 cm) external beam radiotherapy (5500 cGy in 20 treatments over 4 weeks); two cervical cancer patients had been given whole pelvis, external beam radiotherapy supplemented by a single caesium implant (cumulative dosage of 9500 cGy to the vaginal vault, equivalent to 7500 cG to point A). (UK)

  19. Development of technique to apply induction heating stress improvement to recirculation inlet nozzle

    International Nuclear Information System (INIS)

    Chiba, Kunihiko; Nihei, Kenichi; Ootaka, Minoru

    2009-01-01

    Stress corrosion cracking (SCC) have been found in the primary loop recirculation (PLR) systems of boiling water reactors (BWR). Residual stress in welding heat-affected zone is one of the factors of SCC, and the residual stress improvement is one of the most effective methods to prevent SCC. Induction heating stress improvement (IHSI) is one of the techniques to improve reduce residual stress. However, it is difficult to apply IHSI to the place such as the recirculation inlet nozzle where the flow stagnates. In this present study, the technique to apply IHSI to the recirculation inlet nozzle was developed using water jet which blowed into the crevice between the nozzle safe end and the thermal sleeve. (author)

  20. Pre-operative and early post-operative factors associated with surgical site infection after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Ruiz-Tovar, Jaime; Oller, Inmaculada; Llavero, Carolina; Arroyo, Antonio; Muñoz, Jose Luis; Calero, Alicia; Diez, María; Zubiaga, Lorea; Calpena, Rafael

    2013-08-01

    Surgical procedures on obese patients are expected to have a high incidence of surgical site infection (SSI). The identification of pre-operative or early post-operative risk factors for SSI may help the surgeon to identify subjects in risk and adequately optimize their status. We conducted a study of the association of comorbidities and pre- and post-operative analytical variables with SSI following laparoscopic sleeve gastrectomy for the treatment of morbid obesity. We performed a prospective study of all morbidly obese patients undergoing laparoscopic sleeve gastrectomy as a bariatric procedure between 2007 and 2011. An association of clinical and analytical variables with SSI was investigated. The study included 40 patients with a mean pre-operative body mass index (BMI) of 51.2±7.9 kg/m(2). Surgical site infections appeared in three patients (7.5%), of whom two had an intra-abdominal abscess located in the left hypochondrium and the third had a superficial incisional SSI. Pre-operatively, a BMI >45 kg/m(2) (OR 8.7; p=0.008), restrictive disorders identified by pulmonary function tests (OR 10.0; p=0.012), a serum total protein concentration 30 mcg/dL (OR 13.0; p=0.003), and a mean corpuscular volume (MCV) operative SSI. Post-operatively, a serum glucose >128 mg/dL (OR 4.7; p=0.012) and hemoglobin operative anemia and hyperglycemia as risk factors for SSI. In these situations, the surgeon must be aware of and seek to control these risk factors.

  1. Sleeve bridging of the rhesus monkey ulnar nerve with muscular branches of the pronator teres: multiple amplification of axonal regeneration

    OpenAIRE

    Yu-hui Kou; Pei-xun Zhang; Yan-hua Wang; Bo Chen; Na Han; Feng Xue; Hong-bo Zhang; Xiao-feng Yin; Bao-guo Jiang

    2015-01-01

    Multiple-bud regeneration, i.e., multiple amplification, has been shown to exist in peripheral nerve regeneration. Multiple buds grow towards the distal nerve stump during proximal nerve fiber regeneration. Our previous studies have verified the limit and validity of multiple amplification of peripheral nerve regeneration using small gap sleeve bridging of small donor nerves to repair large receptor nerves in rodents. The present study sought to observe multiple amplification of myelinated ne...

  2. SPIDER ® sleeve gastrectomy--a new concept in single-trocar bariatric surgery: initial experience and technical details.

    Science.gov (United States)

    Noel, P; Nedelcu, M; Gagner, M

    2014-04-01

    Single port instrument delivery extended reach (SPIDER(®)) surgical system is a revolutionary surgical platform that allows triangulation of the surgical instruments while eliminating the crossing of instruments, the problematic characteristic of single access laparoscopic surgery. The purpose of this study was to analyze our initial experience with SPIDER(®) sleeve gastrectomy and to present the technical details of this new minimally invasive approach, performed in ten patients at the La Casamance Private Hospital between November 2012 and April 2013. All patients were reviewed at scheduled post-operative consultations at 1, 3 and 6 months. In addition to clinical examination, the post-operative consultation at one month also included a satisfaction survey using the Moorehead-Ardelt questionnaire. An initial series of ten sleeve gastrectomies were performed in female patients with a mean age of 41.5 years (range: 2-52). The mean BMI was 40.11 (range: 37.25-44.3). The intervention was performed through a single trocar in all patients with no "conversion" to classic laparoscopy or open surgery. The mean operative time was 61 ± 15.22 minutes (SD=standard deviation) (range: 43-96 min). The mean BMI at one month was 35.5 (SD:± 3.58, SEM: ± 1.13) (SEM=standard error of mean) with an average percentage of excess weight loss (%EWL) of 32.9% (SD:± 8.56%, SEM:± 2.71%). The mean BMI at three months was 32.4 (SD: ± 2.78, SEM: ± 0.88) with an average %EWL of 52.7% (SD: ± 8.64%, SEM: ± 2.73%). The mean BMI at six months was 29.9 (SD:± 2.60, SEM: ± 0.98) with a mean %EWL of 68.8% (SD: ± 8.38%, SEM:± 3.17%). Complete remission of co-morbid conditions was observed in four patients, improvement in three others, and no change in a single patient. The mean duration of hospitalization was 3.1 days. The mean follow-up period was 161 days (SD:± 57.4 days, range: 90-243 days). There was no mortality and no intra-operative and post-operative complications were noted. The

  3. Triaxial testing system for pressure core analysis using image processing technique

    Science.gov (United States)

    Yoneda, J.; Masui, A.; Tenma, N.; Nagao, J.

    2013-11-01

    In this study, a newly developed innovative triaxial testing system to investigate strength, deformation behavior, and/or permeability of gas hydrate bearing-sediments in deep sea is described. Transport of the pressure core from the storage chamber to the interior of the sealing sleeve of a triaxial cell without depressurization was achieved. An image processing technique was used to capture the motion and local deformation of a specimen in a transparent acrylic triaxial pressure cell and digital photographs were obtained at each strain level during the compression test. The material strength was successfully measured and the failure mode was evaluated under high confining and pore water pressures.

  4. A New Algorithm to Reduce the Incidence of Gastroesophageal Reflux Symptoms after Laparoscopic Sleeve Gastrectomy.

    Science.gov (United States)

    Ece, Ilhan; Yilmaz, Huseyin; Acar, Fahrettin; Colak, Bayram; Yormaz, Serdar; Sahin, Mustafa

    2017-06-01

    Laparoscopic sleeve gastrectomy (LSG) is one of the most prefered treatment option for morbid obesity. However, the effects of LSG on gastroesophageal reflux disease (GERD) are controversial. Asymptomatic GERD and hiatal hernia (HH) is common in obese patients. Therefore, it is important to identify the high risk patients prior to surgery. This study aims to evaluate efficacy of cruroplasty for HH during LSG in morbidly obese patients using ambulatory pH monitoring (APM) results, and to investigate the patients' selection criteria for this procedure. This retrospective study includes outcomes of 59 patients who underwent LSG and HH repair according to our patient selection algorithm. Outcomes included preoperative GERD Health-Related Quality of Life (GERD-HRQL) questionnaire, APM results, percentage of postoperative excess weight loss, and total weight loss. For a total of 402 patients, APM was applied in 70 patients who had a positive score of GERD-HRQL, and 59 patients underwent LSG and concomitant HH repair who had a DeMeester score of 14.7% or above. There was no statistically significant difference in weight loss at 6 and 12-month follow-up. Two patients (3.3%) had symptoms of GERD at 12 months postoperatively, and only one (1.6%) patient required treatment of proton pump inhibitor for reflux. In the total cohort, 11 (2.7%) patients also evolved de novo GERD symptoms. This study confirm that careful attention to patient selection and surgical technique can reduce the symptoms of GERD at short-term. Routine bilateral crus exploration could be a major risk factor of postoperative GERD.

  5. Improvement in cardiovascular risk in women after bariatric surgery as measured by carotid intima-media thickness: comparison of sleeve gastrectomy versus gastric bypass.

    Science.gov (United States)

    Gómez-Martin, Jesús M; Aracil, Enrique; Galindo, Julio; Escobar-Morreale, Héctor F; Balsa, José A; Botella-Carretero, José I

    2017-05-01

    Bariatric surgery may diminish cardiovascular risk (CVR) and its associated mortality. However, studies that compare these effects with different techniques are scarce. To evaluate the changes in CVR as estimated by carotid intima-media thickness (IMT) after obesity surgery in women with high CVR as defined by the presence of metabolic syndrome. Academic hospital. We studied 40 severely obese women, of whom 20 received laparoscopic Roux en Y gastric bypass (RYGB) and 20 received sleeve gastrectomy (SG). Twenty control women matched for age and cardiovascular risk were also included. Patients and controls were evaluated at baseline and 1 year after surgery or conventional treatment with diet and exercise, respectively. Only 18 of the 20 women in the control group were available for analysis after 1 year. None of the women who had bariatric surgery was lost to follow-up. Mean carotid IMT decreased 1 year after surgery irrespective of the surgical technique used, whereas no changes were observed in the control women who had conventional therapy (Wilks´ λ = .802, P = .002 for the interaction, P = .011 for RYGB versus controls, P = .002 for SG versus controls, P = .349 for RYGB versus SG). Both RYGB and SG decrease CVR as measured by carotid IMT in obese women. Copyright © 2017 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  6. Self-esteem and quality of life in adolescents with extreme obesity in Saudi Arabia: the effect of weight loss after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Aldaqal, Saleh M; Sehlo, Mohammad G

    2013-01-01

    To evaluate the self-esteem and quality of life in adolescents with extreme obesity before and one year after laparoscopic sleeve gastrectomy as obesity is a major challenging medical problem, not only in adults but also in children and adolescents in Saudi Arabia. In a prospective cohort study, 32 adolescents (aged 13-17 years) with extreme obesity (Group 1) presenting for laparoscopic sleeve gastrectomy (LSG) were compared with 32 matched, healthy, nonobese adolescents (aged 14-17 years) (Group 2) with regards to self-esteem and quality of life. Assessment was done using the Rosenberg Self-Esteem Scale and Pediatric Quality of Life Inventory version 4.0 (self- and parent report), respectively. Body mass index (BMI) Z scores were calculated for both groups. We found significantly poor self-esteem and impairment in all domains of quality of life (self- and parent report) in Group 1 compared with Group 2 (Pself-esteem (R2=0.28 and P=.003) and quality of life (R(2)=0.67 and Padolescents with extreme obesity: LSG leads to weight loss, with subsequent improvement in self-esteem and quality of life. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Combustion-driven oscillation in a furnace with multispud-type gas burners. 4th Report. Effects of position of secondary air guide sleeve and openness of secondary air guide vane on combustion oscillation condition; Multispud gata gas turner ni okeru nensho shindo. 4. Nijigen kuki sleeve ichi oyobi nijigen kuki vane kaido no shindo reiki ni oyobosu eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Akiyama, I.; Okiura, K.; Baba, A.; Orimoto, M. [Babcock-Hitachi K.K., Tokyo (Japan)

    1994-07-25

    Effects of the position of a secondary air guide sleeve and the openness of a secondary air guide vane on combustion oscillation conditions were studied experimentally for multispud-type gas burners. Pressure fluctuation in furnaces was analyzed with the previously reported resonance factor which was proposed as an index to represent the degree of combustion oscillation. As a result, the combustion oscillation region was largely affected by both position of a guide sleeve and openness of a guide vane. As the openness having large effect on the ratio of primary and secondary air/tertiary air and the position hardly having effect on the ratio were adjusted skillfully, the burner with no combustion oscillation region was achieved in its normal operation range. In addition, as the effect of preheating combustion air was arranged with a standard flow rate or mass flow flux of air, it was suggested the combustion oscillation region due to preheating can be described with the same manner as that due to no preheating. 5 refs., 8 figs.

  8. Air velocity profiles near sleeve blockages in an unheated 7 x 7 rod bundle. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Creer, J. M.; Bates, J. M.

    1979-04-01

    Local air velocity measurements were obtained with a laser Doppler anemometer near flow blockages in an unheated 7 x 7 rod bundle. Sleeve blockages were positioned on the center nine rods to create an area reduction of 90% in the center four subchannels of the bundle. Experimental results indicated that severe flow disturbances occurred downstream from the blockage cluster but showed only minor flow disturbances upstream from the blockage. Flow reversals were detected downstream from the blockage and persisted for approximately five subchannel hydraulic diameters. The air velocity profiles were in excellent agreement with water velocity data previously obtained at essentially the same Reynolds number. Subchannel average velocity predictions obtained with the COBRA computer program were in good agreement with subchannel average velocities estimated using the measured local velocity data.

  9. Strategic laparoscopic surgery for improved cosmesis in general and bariatric surgery: analysis of initial 127 cases.

    Science.gov (United States)

    Nguyen, Ninh T; Smith, Brian R; Reavis, Kevin M; Nguyen, Xuan-Mai T; Nguyen, Brian; Stamos, Michael J

    2012-05-01

    Strategic laparoscopic surgery for improved cosmesis (SLIC) is a less invasive surgical approach than conventional laparoscopic surgery. The aim of this study was to examine the feasibility and safety of SLIC for general and bariatric surgical operations. Additionally, we compared the outcomes of laparoscopic sleeve gastrectomy with those performed by the SLIC technique. In an academic medical center, from April 2008 to December 2010, 127 patients underwent SLIC procedures: 38 SLIC cholecystectomy, 56 SLIC gastric banding, 26 SLIC sleeve gastrectomy, 1 SLIC gastrojejunostomy, and 6 SLIC appendectomy. SLIC sleeve gastrectomy was initially performed through a single 4.0-cm supraumbilical incision with extraction of the gastric specimen through the same incision. The technique evolved to laparoscopic incisions that were all placed within the umbilicus and suprapubic region. There were no 30-day or in-hospital mortalities or 30-day re-admissions or re-operations. For SLIC cholecystectomy, gastric banding, appendectomy, and gastrojejunostomy, conversion to conventional laparoscopy occurred in 5.3%, 5.4%, 0%, and 0%, respectively; there were no major or minor postoperative complications. For SLIC sleeve gastrectomy, there were no significant differences in mean operative time and length of hospital stay compared with laparoscopic sleeve gastrectomy; 1 (3.8%) of 26 SLIC patients required conversion to five-port laparoscopy. There were no major complications. Minor complications occurred in 7.7% in the SLIC sleeve group versus 8.3% in the laparoscopic sleeve group. SLIC in general and bariatric operations is technically feasible, safe, and associated with a low rate of conversion to conventional laparoscopy. Compared with laparoscopic sleeve gastrectomy, SLIC sleeve gastrectomy can be performed without a prolonged operative time with comparable perioperative outcomes.

  10. Portomesenteric Vein Thrombosis After Laparoscopic Sleeve Gastrectomy: Incidence, Analysis and Follow-Up in 1236 Consecutive Cases.

    Science.gov (United States)

    Villagrán, Rodrigo; Smith, Gabriela; Rodriguez, Walter; Flores, Carlos; Cariaga, Mario; Araya, Sofía; Yañez, Marisol; Fuentes, Paulina; Linares, Jeannette; Zapata, Antonio

    2016-11-01

    Portomesenteric vein thrombosis (PMVT) is a rare but severe complication after laparoscopic bariatric surgery, with potentially serious consequences. We aimed to describe the incidence, clinical features, management, outcome, and midterm follow-up in patients with PMVT after laparoscopic sleeve gastrectomy (LSG). This retrospective and descriptive study included patients who underwent LSG between November 2009 and July 2015 and developed PMVT. The following data were analyzed: age, gender, body mass index (BMI), thrombosis risk factors, surgical technique, thromboembolic prophylaxis, primary surgery outcomes, clinical features, treatment, thrombophilia testing results, and follow-up findings, including imaging and endoscopic findings. A total of 1236 patients underwent LSG, and 5 (0.4 %) developed PMVT. The mean age was 34.4 years, and 3 patients were women. The mean BMI was 38.5 kg/m 2 . Two patients had received hormonal contraceptive treatment. Four patients had a history of smoking. All of the patients received anticoagulant treatment, and none required surgery. The mean hospitalization duration was 7.6 days. Two patients showed complete recanalization. One patient showed portal cavernomatosis on delayed images. Two patients had a positive thrombophilia test. No portal hypertension endoscopic findings were observed. PMVT is a rare complication, for which smoking was identified as a predominant risk factor. Early diagnosis and prompt anticoagulant therapy could lead to a dramatic decrease in the incidence of intestinal infarction, mortality, and extrahepatic portal hypertension in the near future. However, careful follow-up is necessary to evaluate the impact of PMVT on long-term patient outcomes.

  11. Dorsal Slit‑Sleeve Technique for Male Circumcision

    African Journals Online (AJOL)

    with field block of the penis using plain lignocaine (0.25%). Lignocaine with adrenalin must be avoided owing to its ... The field block with plain lignocaine gives good postoperative analgesia. This is complimented with paracetamol syrup or ... TB, editors. Andrology for the clinician. Springer-Verlag: Berlin; 2006. p. 203-12. 2.

  12. Change in levels of C-reactive protein (CRP) and serum cortisol in morbidly obese patients after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Ruiz-Tovar, Jaime; Oller, Inmaculada; Galindo, Isabel; Llavero, Carolina; Arroyo, Antonio; Calero, Alicia; Diez, María; Zubiaga, Lorea; Calpena, Rafael

    2013-06-01

    C-Reactive protein (CRP) has been associated with the macro- and microvascular effects of hypertension and diabetes mellitus. Referring to serum cortisol, it has been proposed to contribute to the pathogenesis of metabolic syndrome, and it has been demonstrated that weight loss normalizes cortisol levels and improves insulin resistance. The aims of this study were to analyze CRP and cortisol levels pre- and postoperatively in morbidly obese patients undergoing a laparoscopic sleeve gastrectomy and to correlate them with weight loss and parameters associated with cardiovascular risk. A prospective study of all the morbidly obese patients undergoing laparoscopic sleeve gastrectomy as bariatric procedure between October 2007 and May 2011 was performed. A total of 40 patients were included in the study. CRP levels decreased significantly 12 months after surgery (median reduction of 8.9 mg/l; p = 0.001). Serum cortisol levels decreased significantly 6 months after surgery (median reduction of 34.9 μg/dl; p = 0.001). CRP values reached the normal range (cortisol, a significant association was observed with the cardiovascular risk predictor (triglyceride/high-density lipoprotein cholesterol ratio) from the 6th month after surgery onward (Pearson correlation coefficient, 0.559; p = 0.008). CRP levels are increased preoperatively and in the postoperative course up to 1 year after surgery. Serum cortisol levels remain elevated until the 6th month after surgery. From this moment onward, serum cortisol is associated with the cardiovascular risk predictor reflecting the cardiovascular risk decreasement during the weight loss.

  13. Effects of Sleeve Gastrectomy vs. Roux-en-Y Gastric Bypass on Eating Behavior and Sweet Taste Perception in Subjects with Obesity

    Directory of Open Access Journals (Sweden)

    Katie Nance

    2017-12-01

    Full Text Available The goal of this study was to test the hypothesis that weight loss induced by Roux-en-Y gastric bypass (RYGB has greater effects on taste perception and eating behavior than comparable weight loss induced by sleeve gastrectomy (SG. We evaluated the following outcomes in 31 subjects both before and after ~20% weight loss induced by RYGB (n = 23 or SG (n = 8: (1 sweet, savory, and salty taste sensitivity; (2 the most preferred concentrations of sucrose and monosodium glutamate; (3 sweetness palatability, by using validated sensory testing techniques; and (4 eating behavior, by using the Food Craving Inventory and the Dutch Eating Behavior Questionnaire. We found that neither RYGB nor SG affected sweetness or saltiness sensitivity. However, weight loss induced by either RYGB or SG caused the same decrease in: (1 frequency of cravings for foods; (2 influence of emotions and external food cues on eating behavior; and (3 shifted sweetness palatability from pleasant to unpleasant when repetitively tasting sucrose (all p-values ≤ 0.01. Therefore, when matched on weight loss, SG and RYGB cause the same beneficial effects on key factors involved in the regulation of eating behavior and hedonic component of taste perception.

  14. Sleeve Gastrectomy Combined with the Simplified Hill Repair in the Treatment of Morbid Obesity and Gastro-esophageal Reflux Disease: Preliminary Results in 14 Patients.

    Science.gov (United States)

    Gero, Daniel; Ribeiro-Parenti, Lara; Arapis, Konstantinos; Marmuse, Jean-Pierre

    2017-04-01

    Our aim is to report our initial experience with a novel technique which addresses morbid obesity and gastro-esophageal reflux disease (GERD) simultaneously by combination of laparoscopic sleeve gastrectomy (LSG) and simplified laparoscopic Hill repair (sLHR). Retrospective analysis of LSG+sLHR patients >5 months postoperatively includes demographics, GERD status, proton-pump inhibitor (PPI) use, body mass index (BMI), excess BMI loss (EBMIL), complications and GERD-Health Related Quality of Life (GERD-HRQL) questionnaire. LSG+sLHR surgical technique: posterior cruroplasty,  standard LSG, fixation of the esophagogastric junction to the median arcuate ligament. Fourteen patients underwent LSG+sLHR [12 women and 2 men, mean (range) age 47 years (27-57), BMI 41 kg/m 2 (35-65)]. Five patients had previous gastric banding (GB). All had symptomatic GERD confirmed by gastroscopy and/or upper-gastrointestinal contrast study, two with chronic cough, 10 took PPI daily. Twelve had hiatus hernia and two patulous cardia at surgical exploration. Associated interventions were three GB removals and one cholecystectomy. Postoperative complication was one surgical site infection. Follow-up of all patients at median 12.5 months (5-17) is as follows: symptomatic GERD 3/14 patients, chronic cough 0/14, daily PPI use in 1/14, mean EBMIL 68% (17-120), satisfaction 93%, mean GERD-HRQL score 3,28/50 (0-15), with 4 patients 0/50, occasional bloatedness in 2 patients and dysphagia not reported. The novel technique which combines LSG with sLHR is feasible, safe and can be associated with GB removal. Preliminary results showed patient satisfaction, high remission rate of preexisting GERD, decrease in PPI use and unimpaired weight loss. Further evaluation is necessary in a controlled and staged manner to establish the technique's real effectiveness.

  15. Complications, Reoperations, and Nutrient Deficiencies Two Years after Sleeve Gastrectomy

    Directory of Open Access Journals (Sweden)

    Nicole Pech

    2012-01-01

    Full Text Available Background. The aim of this study was to investigate patient outcomes and nutritional deficiencies following sleeve gastrectomy (SG during a follow-up of two years. Methods. Over a period of 56 months, all consecutive patients who underwent SG were documented in this prospective, single-center, observational study. The study endpoints included operative time, complication rates, nutritional deficiencies and percentage of excess weight loss (%EWL. Results. From September 26, 2005 to May 28, 2009, 82 patients (female : male = 48 : 34 with a mean age of 43.3 years (range: 22–64 and a preoperative BMI of 52.5 kg/m² (range: 36.8–77.0 underwent SG. Major complications were observed in 9.8% of the patients, with 1 death. During follow up 51.2% of patients were supplemented with iron, 36.6% with zinc, 37.8% with calcium, 26.8% with vitamin D, 46.3% with vitamin B12 and 41.5% with folic acid. %EWL was 54.3, 65.3 and 62.6% after 6, 12 and 24 months. Conclusion. SG as a single step procedure is an effective bariatric intervention. Nutritional deficiencies after SG can be detected by routine nutritional screening. Our results show that Vitamin B12 supplementation should suggest routinely after SG.

  16. Operation modes research of liquefied natural gas storages as a part of the ground complexes equipment

    Directory of Open Access Journals (Sweden)

    N. S. Korolev

    2014-01-01

    Full Text Available The use of the Liquefied Natural Gas (LNG in the space-rocket equipment is motivated by some advantages. That is why a lot of tests and works are actively carried out now on rocket engines using liquefied natural gas.To provide the engine tests and subsequent rocket complex operation a creation of LNG storages is demanded as a part of ground processing equipment and support for their safe operation conditions.One of LNG danger factor is its low boiling temperature, and also changing the condition, density and LNG boiling temperature at storage due to evaporation of light component, namely methane. At refill of the storages having fuel remains with a new LNG portion these factors can lead to formation of the stratified macro-layers and cause a mode of the intensive mixing that is called "rollover", with almost instant evaporation of LNG big mass and sharp pressure boost, capable to result in the storage distraction with catastrophic effects.The work objectives are formulated such as a technique development for forecasting of the LNG parameters in operating storages including the rollover mode, a comparison of calculated results of the LNG parameters with the experimental data, and a definition of possible recommendations for safe operation of LNG storages as a part of the ground complexes equipment.The paper reviews 12 publications concerning the issues and proceeding processes at operation of LNG storages, including the rollover mode.To verify the reliability of process simulation results in the LNG, represented in models by the binary methane-ethane mixture the calculated values have been compared with the experimental data for a LNG storage mode in the reservoir of a ground test complex.The reliability of developed models of the heat-mass-exchange processes in stratified on density and temperature in LNG storage with emergence of conditions for the rollover mode has been verified by comparing the settlement characteristics to the published

  17. Mechanistic comparison between gastric bypass vs. duodenal switch with sleeve gastrectomy in rat models.

    Directory of Open Access Journals (Sweden)

    Yosuke Kodama

    Full Text Available BACKGROUND: Both gastric bypass (GB and duodenal switch with sleeve gastrectomy (DS have been widely used as bariatric surgeries, and DS appears to be superior to GB. The aim of this study was to better understand the mechanisms leading to body weight loss by comparing these two procedures in experimental models of rats. METHODS: Animals were subjected to GB, DS or laparotomy (controls, and monitored by an open-circuit indirect calorimeter composed of comprehensive laboratory animal monitoring system and adiabatic bomb calorimeter. RESULTS: Body weight loss was greater after DS than GB. Food intake was reduced after DS but not GB. Energy expenditure was increased after either GB or DS. Fecal energy content was increased after DS but not GB. CONCLUSION: GB induced body weight loss by increasing energy expenditure, whereas DS induced greater body weight loss by reducing food intake, increasing energy expenditure and causing malabsorption in rat models.

  18. Nutritional Status Prior to Laparoscopic Sleeve Gastrectomy Surgery.

    Science.gov (United States)

    Sherf Dagan, Shiri; Zelber-Sagi, Shira; Webb, Muriel; Keidar, Andrei; Raziel, Asnat; Sakran, Nasser; Goitein, David; Shibolet, Oren

    2016-09-01

    Two main causes for nutrient deficiencies following bariatric surgery (BS) are pre-operative deficiencies and favoring foods with high-energy density and poor micronutrient content. The aims of this study were to evaluate nutritional status and gender differences and the prevalence of nutritional deficiencies among candidates for laparoscopic sleeve gastrectomy (LSG) surgery. A cross-sectional analysis of pre-surgery data collected as part of a randomized clinical trial on 100 morbidly obese patients with non-alcoholic fatty liver disease (NAFLD) admitted to LSG surgery at Assuta Medical Center between February 2014 and January 2015. Anthropometrics, food intake, and fasting blood tests were evaluated during the baseline visit. One-hundred patients completed the pre-operative measurements (60 % female) with a mean age of 41.9 ± 9.8 years and a mean BMI of 42.3 ± 4.7 kg/m(2). Pre-operatively, deficiencies for iron, ferritin, folic acid, vitamin B1, vitamin B12, vitamin D, and hemoglobin were 6, 1, 1, 6, 0, 22, and 6 %, respectively. Pre-surgery, mean energy, protein, fat, and carbohydrate intake were 2710.7 ± 1275.7 kcal/day, 114.2 ± 48.5, 110.6 ± 54.5, and 321.6 ± 176.1 gr/day, respectively. The intakes for iron, calcium, folic acid, vitamin B12, and vitamin B1 were below the Dietary Reference Intake (DRI) recommendations for 46, 48, 58, 14, and 34 % of the study population, respectively. We found a low prevalence of nutritional deficiencies pre-operatively except for vitamin D. Most micronutrient intake did not reach the DRI recommendations, despite high-caloric and macronutrient intake indicating a poor dietary quality.

  19. Paediatric sutureless circumcision-an alternative to the standard technique.

    LENUS (Irish Health Repository)

    2012-01-31

    INTRODUCTION: Circumcision is one of the most commonly performed surgical procedures in male children. A range of surgical techniques exist for this commonly performed procedure. The aim of this study is to assess the safety, functional outcome and cosmetic appearance of a sutureless circumcision technique. METHODS: Over a 9-year period, 502 consecutive primary sutureless circumcisions were performed by a single surgeon. All 502 cases were entered prospectively into a database including all relevant clinical details and a review was performed. The technique used to perform the sutureless circumcision is a modification of the standard sleeve technique with the use of a bipolar diathermy and the application of 2-octyl cyanoacrylate (2-OCA) to approximate the tissue edges. RESULTS: All boys in this study were pre-pubescent and the ages ranged from 6 months to 12 years (mean age 3.5 years). All patients had this procedure performed as a day case and under general anaesthetic. Complications included: haemorrhage (2.2%), haematoma (1.4%), wound infection (4%), allergic reaction (0.2%) and wound dehiscence (0.8%). Only 9 (1.8%) parents or patients were dissatisfied with the cosmetic appearance. CONCLUSION: The use of 2-OCA as a tissue adhesive for sutureless circumcisions is an alternative to the standard suture technique. The use of this tissue adhesive, 2-OCA, results in comparable complication rates to the standard circumcision technique and results in excellent post-operative cosmetic satisfaction.

  20. Semiextended approach for intramedullary nailing via a patellar eversion technique for tibial-shaft fractures: Evaluation of the patellofemoral joint.

    Science.gov (United States)

    Yasuda, Tomohiro; Obara, Shu; Hayashi, Junji; Arai, Masayuki; Sato, Kaoru

    2017-06-01

    Intramedullary nail fixation is a common treatment for tibial-shaft fractures, and it offers a better functional prognosis than other conservative treatments. Currently, the primary approach employed during intramedullary nail insertion is the semiextended position is the suprapatellar approach, which involves a vertical incision of the quadriceps tendon Damage to the patellofemoral joint cartilage has been highlighted as a drawback associated with this approach. To avoid this issue, we perform surgery using the patellar eversion technique and a soft sleeve. This method allows the articular surface to be monitored during intramedullary nail insertion. We arthroscopically assessed the effect of this technique on patellofemoral joint cartilage. The patellar eversion technique allows a direct view and protection of the patellofemoral joint without affecting the patella. Thus, damage to the patellofemoral joint cartilage can be avoided. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Dietary intake and ghrelin and leptin changes after sleeve gastrectomy.

    Science.gov (United States)

    Bužga, Marek; Zavadilová, Vladislava; Holéczy, Pavol; Švagera, Zdeněk; Švorc, Pavol; Foltys, Aleš; Zonča, Pavel

    2014-12-01

    Surgical intervention in obesity is today the most effective treatment method in high level obesity management. Bariatric interventions not only ensure body weight reduction, but may influence dietary habits. To assess changes in adipose hormones and dietary habits in obese patients after sleeve gastrectomy. The study set comprised 37 subjects (29 females and 8 males) 24 to 68 years old with body mass index 43.0 ±4.9 kg/m(2). Pre-operative examination included baseline measurements of body composition. Dietary habits and intake frequency were monitored by a questionnaire method. Follow-up examinations were carried out in a scope identical to the pre-operative examination, 6 and 12 months after surgery, respectively. The average patient weight loss 12 months after surgery was 31.7 kg. Excess weight loss was 55.2 ±20.6%. Patients reported reduced appetite (p meal portions per day (p = 0.003) and a decrease in consuming the largest portions during the afternoon and evening (p = 0.030). Plasma levels of fasting glucose, leptin and ghrelin significantly decreased (p = 0.006; p = 0.0.043); in contrast, the level of adiponectin significantly increased (p weight reduction within 1 year after surgery. An improvement of certain dietary habits in patients was registered. At 12 months after surgery, there were no statistically significant differences in decreases in ghrelin and leptin concentrations between patients without changed appetite and those reporting decreased appetite.

  2. Review of Surgical Techniques of Experimental Renal Transplantation in Rats.

    Science.gov (United States)

    Shrestha, Badri; Haylor, John

    2017-08-01

    Microvascular surgical techniques of renal transplant in rats have evolved over the past 5 decades to achieve successful rat renal transplant; these modifications have included surgical techniques to address the anatomic variations in the renal blood vessels and those to reduce ischemic and operation durations. Here, we review the surgical techniques of renal transplant in rats and evaluate the advantages and disadvantages of individual techniques of vascular and ureteric anastomoses. For this review, we performed a systematic literature search using relevant medical subject heading terms and included appropriate publications in the review. Since the first description of a rat model of renal transplant by Bernard Fisher and his colleagues in 1965, which used end-to-side anastomosis between the renal vein and renal artery to the recipient inferior vena cava and aorta, several vascular and ureteric anastomosis techniques have been modified. Vascular anastomosis techniques now include end-to-end anastomosis, use of donor aortic and inferior vena cava conduits, sleeve and cuff anastomoses, and application of fibrin glue. Likewise, restoration of the urinary tract can now be achieved by direct anastomosis of the donor ureter to the recipient bladder, end-to-end anastomosis between the donor and recipient ureters, and donor bladder cuff to the recipient bladder. There are advantages and disadvantages attributable to individual techniques. The range of vascular and ureteric anastomosis techniques that has emerged reflects the need for mastering more than one technique to suit the vascular anatomy of individual animals and to reduce operating time for achieving successful outcomes after renal transplant.

  3. Are there risk factors that increase the rate of staple line leakage in patients undergoing primary sleeve gastrectomy for morbid obesity?

    Science.gov (United States)

    Benedix, Frank; Benedix, Diana D; Knoll, Christian; Weiner, Rudolf; Bruns, Christiane; Manger, Thomas; Stroh, Christine

    2014-10-01

    Laparoscopic sleeve gastrectomy (LSG) is currently being performed with increasing frequency worldwide. It offers an excellent weight loss and resolution of comorbidities in the short term with a very low incidence of complications. However, the ever present risk of a staple line leak is still a major concern. Since 2005, data from obese patients that undergo bariatric procedures in Germany are prospectively registered in an online database and analyzed at the Institute of Quality Assurance in Surgical Medicine. For the current analysis, all patients that had undergone primary sleeve gastrectomy for morbid obesity within a 7-year period were considered. Using the GBSR, data from 5.400 LSGs were considered for analysis. Staple line leak rate decreased during the study period from 6.5 to 1.4 %. Male gender, higher BMI, concomitant sleep apnea, conversion to laparotomy, longer operation time, use of both buttresses and oversewing, and the occurrence of intraoperative complications were associated with a significantly higher leakage rate. On multivariate analysis, operation time and year of procedure only had a significant impact on staple line leak rate. The results of the current study demonstrated that there are factors that increase the risk of a leakage which would enable surgeons to define risk groups, to more carefully select patients, and to offer a closer follow-up during the postoperative course with early recognition and adequate treatment. All future efforts should be focused on a further reduction of serious complications to make the LSG a widely accepted and safer procedure.

  4. Complications and nutrient deficiencies two years after sleeve gastrectomy

    Directory of Open Access Journals (Sweden)

    Pech Nicole

    2012-07-01

    Full Text Available Abstract Background The aim of this systematic study was to investigate patient outcomes and nutritional deficiencies following sleeve gastrectomy (SG during a median follow-up of two years. Methods Over a period of 56 months, all consecutive patients who underwent SG were documented in this prospective, single-center, observational study. The study endpoints included complication rates, nutritional deficiencies and percentage of excess weight loss (%EWL. Results From September 26, 2005 to May 28, 2009, 100 patients (female: male = 59:41 with a mean age of 43.6 years (range: 22–64 and a preoperative BMI of 52.3 kg/² (range: 36–77 underwent SG. The mean operative time was 86.4 min (range: 35–275. Major complications were observed in 8.0 % of the patients. During the follow-up period, 25 patients (25.0 % underwent a second bariatric intervention (22 DS and 3 RYGBP. Out of the total 100 patients, 48 % were supplemented with iron, 33 % with zinc, 34 % with a combination of calcium carbonate and cholecalciferol, 24 % with vitamin D, 42 % with vitamin B12 and 40 % with folic acid. The patients who received only a SG (n = 75 had %EWL of 53.6, 65.8 and 62.6 % after 6, 12 and 24 months, respectively. Conclusions SG is a highly effective bariatric intervention for morbidly obese patients. Nutritional deficiencies resulting from the procedure can be detected by routine nutritional screening. Results of the study show that Vitamin B12 supplementation should suggested routinely.

  5. Sleeve bridging of the rhesus monkey ulnar nerve with muscular branches of the pronator teres: multiple amplification of axonal regeneration

    Directory of Open Access Journals (Sweden)

    Yu-hui Kou

    2015-01-01

    Full Text Available Multiple-bud regeneration, i.e., multiple amplification, has been shown to exist in peripheral nerve regeneration. Multiple buds grow towards the distal nerve stump during proximal nerve fiber regeneration. Our previous studies have verified the limit and validity of multiple amplification of peripheral nerve regeneration using small gap sleeve bridging of small donor nerves to repair large receptor nerves in rodents. The present study sought to observe multiple amplification of myelinated nerve fiber regeneration in the primate peripheral nerve. Rhesus monkey models of distal ulnar nerve defects were established and repaired using muscular branches of the right forearm pronator teres. Proximal muscular branches of the pronator teres were sutured into the distal ulnar nerve using the small gap sleeve bridging method. At 6 months after suture, two-finger flexion and mild wrist flexion were restored in the ulnar-sided injured limbs of rhesus monkey. Neurophysiological examination showed that motor nerve conduction velocity reached 22.63 ± 6.34 m/s on the affected side of rhesus monkey. Osmium tetroxide staining demonstrated that the number of myelinated nerve fibers was 1,657 ± 652 in the branches of pronator teres of donor, and 2,661 ± 843 in the repaired ulnar nerve. The rate of multiple amplification of regenerating myelinated nerve fibers was 1.61. These data showed that when muscular branches of the pronator teres were used to repair ulnar nerve in primates, effective regeneration was observed in regenerating nerve fibers, and functions of the injured ulnar nerve were restored to a certain extent. Moreover, multiple amplification was subsequently detected in ulnar nerve axons.

  6. Sleeve bridging of the rhesus monkey ulnar nerve with muscular branches of the pronator teres: multiple amplification of axonal regeneration.

    Science.gov (United States)

    Kou, Yu-Hui; Zhang, Pei-Xun; Wang, Yan-Hua; Chen, Bo; Han, Na; Xue, Feng; Zhang, Hong-Bo; Yin, Xiao-Feng; Jiang, Bao-Guo

    2015-01-01

    Multiple-bud regeneration, i.e., multiple amplification, has been shown to exist in peripheral nerve regeneration. Multiple buds grow towards the distal nerve stump during proximal nerve fiber regeneration. Our previous studies have verified the limit and validity of multiple amplification of peripheral nerve regeneration using small gap sleeve bridging of small donor nerves to repair large receptor nerves in rodents. The present study sought to observe multiple amplification of myelinated nerve fiber regeneration in the primate peripheral nerve. Rhesus monkey models of distal ulnar nerve defects were established and repaired using muscular branches of the right forearm pronator teres. Proximal muscular branches of the pronator teres were sutured into the distal ulnar nerve using the small gap sleeve bridging method. At 6 months after suture, two-finger flexion and mild wrist flexion were restored in the ulnar-sided injured limbs of rhesus monkey. Neurophysiological examination showed that motor nerve conduction velocity reached 22.63 ± 6.34 m/s on the affected side of rhesus monkey. Osmium tetroxide staining demonstrated that the number of myelinated nerve fibers was 1,657 ± 652 in the branches of pronator teres of donor, and 2,661 ± 843 in the repaired ulnar nerve. The rate of multiple amplification of regenerating myelinated nerve fibers was 1.61. These data showed that when muscular branches of the pronator teres were used to repair ulnar nerve in primates, effective regeneration was observed in regenerating nerve fibers, and functions of the injured ulnar nerve were restored to a certain extent. Moreover, multiple amplification was subsequently detected in ulnar nerve axons.

  7. Advanced inspection and repair techniques for primary side components

    International Nuclear Information System (INIS)

    Elm, Ralph

    1998-01-01

    The availability of nuclear power plant mainly depends on the components of the Nuclear Steam Supply System (NSSS) such as reactor pressure vessel, core internals and steam generators. The last decade has been characterized by intensive inspection and repair work on PWR steam generators. In the future, it can be expected, that the inspection of the reactor pressure vessel and the inspection and repair of its internals, in both PWR and BWR will be one of the challenges for the nuclear community. Due to this challenge, new, advanced inspection and repair techniques for the vital primary side components have been developed and applied, taking into account such issues as: use of reliable and fast inspection methods, repair of affected components instead of costly replacement, reduction of outage time compared to conventional methods, minimized radiation exposure, acceptable costs. This paper reflects on advanced inspection and repair techniques such as: Baffle Former Bolt inspection and replacement, Barrel Former Bolt inspection and replacement, Mechanized UT and visual inspection of reactor pressure vessels, Steam Generator repair by advanced sleeving technology. The techniques described have been successfully applied in nuclear power plants and improved the operation performance of the components and the NPP. (author). 6 figs

  8. Portomesenteric venous thrombosis after laparoscopic sleeve gastrectomy: A case report and a call for prevention

    Directory of Open Access Journals (Sweden)

    Parveen Bhatia

    2015-01-01

    Full Text Available Postoperative portomesenteric venous thrombosis (PMVT is being increasingly reported after bariatric surgery. It is variable and often a nonspecific presentation along with its potential for life-threatening and life-altering outcomes makes it imperative that it is prevented, detected early and treated optimally. We report the case of a 50-year-old morbidly obese man undergoing a laparoscopic sleeve gastrectomy who developed symptomatic PMVT two weeks postsurgery, which was successfully treated by anticoagulant therapy. We provide postulates to the etiopathological mechanism for this thrombotic entity. The growing recognition that obesity and bariatric surgery create a procoagulant state regionally and systemically provides impetus for designing the ideal protocol for PMVT prophylaxis, which could be more common than currently believed. We support the early screening for PMVT in the postbariatric surgical patient with unexplainable or intractable abdominal symptoms. The role of routine surveillance and the ideal duration of post-PMVT anticoagulation is yet to be elucidated.

  9. Integrated Approaches for the Management of Staple Line Leaks following Sleeve Gastrectomy

    Directory of Open Access Journals (Sweden)

    Mauro Montuori

    2017-01-01

    Full Text Available Introduction. Aim of the study was trying to draw a final flow chart for the management of gastric leaks after laparoscopic sleeve gastrectomy, based on the review of our cases over 10 years’ experience. Material and Methods. We retrospectively reviewed all patients who underwent LSG as a primary operation at the Bariatric Unit of Tor Vergata University Hospital in Rome from 2007 to 2015. Results. Patients included in the study were 418. There were 6 staple line leaks (1.44%. All patients with diagnosis of a leak were initially discharged home in good clinical conditions and then returned to A&E because of the complication. The mean interval between surgery and readmission for leak was 13,4 days (range 6–34 days, SD ± 11.85. We recorded one death (16.67% due to sepsis. The remaining five cases were successfully treated with a mean healing time of the gastric leak of 55,5 days (range 26–83 days; SD ± 25.44. Conclusion. Choosing the proper treatment depends on clinical stability and on the presence or not of collected abscess. Our treatment protocol showed being associated with low complication rate and minor discomfort to the patients, reducing the need for more invasive procedures.

  10. Sleeve lobectomy versus pneumonectomy for non-small cell lung cancer: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Shi Woda

    2012-12-01

    Full Text Available Abstract Aim It is controversial that whether sleeve lobectomy (SL should be promoted more worthy than pneumonectomy (PN in suitable patients. Methods We searched all studies that had been published in English from PUBMED and Embase which compared the short-term and long-term outcomes of SL and pneumonectomy (PN in patients with non-small cell lung cancer (NSCLC. Results Nineteen studies met our criteria with a combined total of 3878 subjects, of which 1316 (33.9% underwent SL and 2562 (66.1% underwent PN. The odds ratio was 0.50 (95% CI: 0.34-0.72 for postoperative mortality, 1.17 (95% CI: 0.82-1.67 for postoperative complications, 0.78 (95% CI: 0.47-1.29 for locoregional recurrences. The risk difference for 1-, 3-, 5- year was 0.11 (95% CI: 0.07-0.14, 0.15 (95% CI: 0.06-0.24, 0.15 (95% CI: 0.09-0.20,respectively. The pooled hazard ratio was 0.63 (95% CI: 0.56-0.71 in favor of SL group. Conclusion SL is more worthy to be done than PN in suitable patients with less mortality and better long-term survival.

  11. Cardiovascular Risk Factors After Single Anastomosis Duodeno-Ileal Bypass with Sleeve Gastrectomy (SADI-S): a New Effective Therapeutic Approach?

    Science.gov (United States)

    Torres, Antonio; Rubio, Miguel A; Ramos-Leví, Ana M; Sánchez-Pernaute, Andrés

    2017-11-07

    Obesity and its associated comorbidities entail a significantly increased cardiovascular mortality. Therefore, approaching obesity control must include among its aims the reduction of the associated comorbidities and the higher cardiovascular mortality risk and not only weight loss. Many observational studies indicate that bariatric surgery (BS) is associated with a better long-term survival than standard care. Furthermore, in general, these epidemiological studies included patients who underwent gastric bypass (GB), not biliopancreatic diversion/duodenal switch (BPD/DS), so the potential additional benefit of this latter technique remains unknown. In this regard, in theory, derivative techniques are usually associated to a higher rate of long-term improvement of metabolic comorbidities, so their potential impact on cardiovascular morbidity and mortality could be even greater than what has been published up to date. In 2007, our group proposed a simplification of the bariatric technique based on the duodenal switch, which we termed "single anastomosis duodeno-ileal bypass with sleeve gastrectomy" or SADI-S. In this review, and 10 years later, we describe some of the main results of those patients who underwent this procedure, specifically regarding their outcome on metabolic comorbidities and cardiovascular risk. Considering the findings presented in this review, in which a significant improvement of all metabolic comorbidities was observed, we may confidently suggest that SADI-S seems comparable to a BPD/DS procedure in the mid-term outcome. After all, the SADI-S procedure was conceived as a simplified version of the BPD/DS technique and not necessarily intended to maximize the improvement of cardiovascular and metabolic comorbidities, which is already sufficiently optimal. In this regard, in our experience, we have encountered a new satisfactory result, which combines more pros than cons. In fact, as we have seen, after a follow-up of 3 years, the outcomes of

  12. Changes in Gut Hormones After Roux en Y Gastric bypass, Sleeve Gastrectomy, and Adjustable Gastric Banding

    Directory of Open Access Journals (Sweden)

    Miroslav Ilić

    2015-12-01

    Full Text Available The obesity epidemic has burdened healthcare systems worldwide. Bariatric surgery is currently the most effective method for long-term weight loss in obese adults, but the exact mechanism of weight loss is poorly understood. Bariatric procedures were initially classified by their presumed mechanism of action into restrictive, malabsoptive, or mixed procedures; however, due to recent advancements in the field of neuroendocrinology, hormones are increasing being recognized as important regulators of satiation, hunger, and energy expenditure. Studies examining changes in gut hormones following bariatric surgery have yielded conflicting results and the relationship between these hormones and weight loss is nothing but clear. This review will summarize the effect of Roux en Y gastric bypass, sleeve gastrectomy and adjustable gastric banding on various gut hormones including ghrelin, cholecystokinin, glucagon-like polypeptide-1, peptide YY3, and pancreatic polypeptide. Furthermore, the relationship between these hormones and weight loss will be examined.

  13. Management of gastric leaks after laparoscopic sleeve gastrectomy for morbid obesity: A tertiary care experience and design of a management algorithm

    Directory of Open Access Journals (Sweden)

    Palanivelu Praveenraj

    2016-01-01

    Full Text Available Background: Laparoscopic sleeve gastrectomy (LSG is the most commonly performed 'standalone' bariatric procedure in India. Staple line gastric leaks occur infrequently but cause significant and prolonged morbidity. The aim of this retrospective study was to analyse the management of patients with a gastric leak after LSG for morbid obesity at our institution. Patients and Methods: From February 2008 to 2014, 650 patients with different degrees of morbid obesity underwent LSG. Among these, all those diagnosed with a gastric leak were included in the study. Patients referred to our institution with gastric leak after LSG were also included. The time of presentation, site of leak, investigations performed, treatment given and time of closure of all leaks were analysed. Results: Among the 650 patients who underwent LSG, 3 (0.46% developed a gastric leak. Two patients were referred after LSG was performed at another institution. The mean age was 45.60 ± 15.43 years. Mean body mass index (BMI was 44.79 ± 5.35. Gastric leak was diagnosed 24 h to 7 months after surgery. One was early, two were intermediate and two were late leaks. Two were type I and three were type II gastric leaks. Endoscopic oesophageal stenting was used variably before or after re-surgery. Re-surgery was performed in all and included stapled fistula excision (re-sleeve, suture repair only or with conversion to roux-en-Y gastric bypass or fistula jujenostomy. There was no mortality. Conclusion: Leakage closure time may be shorter with intervention than expectant management. Sequence and choice of endoscopic oesophageal stenting and/or surgical re-intervention should be individualized according to clinical presentation.

  14. Efficient frequency-domain numerical analysis of modified surface plasmon waveguides formed by a metallic sleeve and coaxial rod

    International Nuclear Information System (INIS)

    Tian Jinping; Xue Wenrui

    2012-01-01

    Some types of modified surface plasmonic waveguides formed by nanometric silver rods with triangular and square cross-section and a coaxial silver sleeve are proposed in this paper. The finite-difference frequency-domain method is used to study the propagation properties of the fundamental mode supported by these types of surface plasmonic waveguides. The field distribution of the fundamental mode and the dependences of the propagation properties on the geometrical parameters, working wavelength and gain media are discussed in detail. The results show that the above physical properties can be adjusted by choosing proper structure parameters, working wavelength and gain media. So the advantages of the properties of the modes render these waveguides promising optical components or photonic device integration and sensors that would benefit future plasmonic interconnects and circuits.

  15. Video: two novel endoscopic esophageal lengthening and reconstruction techniques.

    Science.gov (United States)

    Perretta, Silvana; Wall, James K; Dallemagne, Bernard; Harrison, Michael; Becmeur, François; Marescaux, Jacques

    2011-10-01

    Esophageal reconstruction presents a significant clinical challenge in patients ranging from neonates with long-gap esophageal atresia to adults after esophageal resection. Both gastric and colonic replacement conduits carry significant morbidity. As emerging organ-sparring techniques become established for early stage esophageal tumors, less morbid reconstruction techniques are warranted. We present two novel endoscopic approaches for esophageal lengthening and reconstruction in a porcine model. Two models of esophageal defects were created in pigs (30-35 kg) under general anesthesia and subsequently reconstructed with the novel techniques. The first model was a segmental defect of the esophagus created by thoracoscopically transecting the esophagus above the gastroesophageal (GE) junction. The first reconstruction technique involved bilateral submucosal endoscopic lengthening myotomies (BSELM) with a magnetic compression anastomosis (MAGNAMOSIS™). The second model was a wedge defect in the anterior esophagus created above the GE junction through a laparotomy. The second reconstruction technique involved an inverted mucosal-submucosal sleeve transposition graft (IMSTG) that crossed the esophageal gap and was secured in place with a self-expandable covered esophageal stent. Both techniques were feasible in the pig model. The BSELM approach lengthened the esophagus 1 cm for every 2 cm length of myotomy. The myotomy targeted only the inner circular fibers of the esophagus, with preservation of the longitudinal layer to protect against long-term dilation and pouching. The IMSTG approach generated a vascularized mucosal graft almost as long as the esophagus itself. Emerging endoscopic capabilities are enabling complex endoluminal esophageal procedures. BSELM and IMSTG are two novel and technically feasible approaches to esophageal lengthening and reconstruction. Further survival studies are needed to establish the safety and efficacy of these techniques.

  16. The behaviour of CAGR moderator and sleeve graphites radiolytically oxidised to high weight loss in inhibited coolant gas compositions

    International Nuclear Information System (INIS)

    Schofield, P.; Fitzgerald, B.; Ketchen, J.

    1987-01-01

    Gilsocarbon graphites were irradiated to high weight losses in three different CO 2 based coolants. The experimental data is tested against a model which interprets the gas phase chemistry and pore geometry and allows weight loss and gas flow properties to be calculated. The observed changes of oxidation rate with dose were successfully predicted from the model. An empirical relationship was also derived which was shown to fit data for moderator, sleeve and special pore structure graphites. Changes in graphite permeability and diffusivity were predicted by the model, and also by other simplified, more approximate methods. The model based upon the measured transport pore spectrum was shown to be the best with other methods proving adequate to moderate doses. (author)

  17. Surface Modification Of The High Temperature Porous Sliding Bearings With Solid Lubricant Nanoparticles

    Directory of Open Access Journals (Sweden)

    Wiśniewska-Weinert H.

    2015-09-01

    Full Text Available A surface modification of stainless steel bearing sleeves is developed to improve the tribology characteristics at high temperature. Solid lubricant nano- and microparticles are applied for this purpose. To create the quasi-hydrodynamic lubrication regimes, the solid lubricant powder layer is made by developed pressure impregnation technique. Porous sliding bearing sleeve prototypes were made by powder metallurgy technique. The purpose of the paper is to define the friction and wear characteristics of the sleeves and to determine the influence of sealing of the sliding interface on these characteristics. It is found that application of WS2 sold lubricant nano- and micro-particles and preservation of a particle leakage out of interface allows to achieve at the high temperature the friction coefficients comparable to those at ambient temperature.

  18. Rodent vertical sleeve gastrectomy alters maternal immune health and fetoplacental development.

    Science.gov (United States)

    Spann, Redin A; Lawson, William J; Bidwell, Gene L; Zamarripa, C Austin; Maranon, Rodrigo O; Bandyopadhyay, Sibali; Taylor, Erin R; Reckelhoff, Jane F; Garrett, Michael R; Grayson, Bernadette E

    2018-01-31

    Bariatric surgery is increasingly employed to improve fertility and reduce obesity-related co-morbidities in obese women. Surgical weight loss not only improves the chance of conception but reduces the risk of pregnancy complications including pre-eclampsia, gestational diabetes, and macrosomia. However, bariatric procedures increase the incidence of intrauterine growth restriction (IUGR), fetal demise, thromboembolism, and other gestational disorders. Using our rodent model of vertical sleeve gastrectomy (VSG), we tested the hypothesis that VSG in diet-induced, obese dams would cause immune and placental structural abnormalities that may be responsible for fetal demise during pregnancy. VSG dams studied on gestational day (G) 19 had reduced circulating T-cell (CD3 + and CD8 + ) populations compared with lean or obese controls. Further, local interleukin (IL) 1β and IL 1 receptor antagonist ( il1rn ) cmRNA were increased in placenta of VSG dams. Placental barrier function was also affected, with increased transplacental permeability to small molecules, increased matrix metalloproteinase 9 expression, and increased apoptosis in VSG. Furthermore, we identified increased placental mTOR signaling that may contribute to preserving the body weight of the fetuses during gestation. These changes occurred in the absence of a macronutrient deficit or gestational hypertension in the VSG dams. In summary, previous VSG in dams may contribute to fetal demise by affecting maternal immune system activity and compromise placental integrity. © 2018 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.

  19. Influence of Sleeve Gastrectomy on NASH and Type 2 Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    W. K. Karcz

    2011-01-01

    Full Text Available Background. Nonalcoholic fatty liver disease is present in up to 85% of adipose patients and may proceed to nonalcoholic steatohepatitis (NASH. With insulin resistance and obesity being the main risk factors for NASH, the effect of isolated sleeve gastrectomy (ISG on these parameters was examined. Methods. 236 patients underwent ISG with intraoperative liver biopsy from December 2002 to September 2009. Besides demographic data, pre-operative weight/BMI, HbA1c, AST, ALT, triglycerides, HDL and LDL levels were determined. Results. A significant correlation of NASH with higher HbA1c, AST and ALT and lower levels for HDL was observed (P<.05, <.0001, <.0001, <.01, resp.. Overall BMI decreased from 45.0 ± 6.8 to 29.7 ± 6.5 and 31.6 ± 4.4 kg/m2 at 1 and 3 years. An impaired weight loss was demonstrated for patients with NASH and patients with elevated HbA1c (plateau 28.08 kg/m2 versus 29.79 kg/m2 and 32.30 kg/m2 versus 28.79 kg/m2, resp.. Regarding NASH, a significant improvement of AST, ALT, triglyceride and HDL levels was shown (P<.0001 for all. A resolution of elevated HbA1c was observed in 21 of 23 patients. Summary. NASH patients showed a significant loss of body weight and amelioration of NASH status. ISG can be successfully performed in these patients and should be recommended for this subgroup.

  20. Development of ABWR inertia-increased reactor internal pump and thicker sleeve nozzle

    International Nuclear Information System (INIS)

    Takahashi, Shirou; Shiina, Kouji; Matsumura, Seiichi

    2002-01-01

    The conventional reactor internal pumps (RIPs) in the ABWR have an inertia moment coming from the shafts and Motor-Generator sets, enabling the RIPs to continue running for a few seconds, when a trip of all RIPs event occurs. It is possible to simplify the RIPs' power supply system without affecting the core flow supply when the above event occurs by eliminating M-G sets, if the rotating inertia is increased. This inertia increase due to an additional flywheel, which leads to gains in weight and length, requires the larger diameter nozzle with the thicker sleeve. However, too large a nozzle diameter may change the hydraulic performance. In authors' previous study, the optimum nozzle diameter (492 mm) was selected through 1/5-scale test. In this study, the 492 mm nozzle and the inertia-increased RIP were verified through the full-scale tests. The rotating inertia time constant on coastdown characteristics (behavior of the RIP speed in the event of power loss) for the inertia-increased RIP doubled compared with the current RIP. The casing and the shaft vibration were also confirmed to satisfy the design criteria. Moreover, hydraulic performance and heat increase in the motor casing due to the flywheel were evaluated. The inertia increased RIP with the 492 mm nozzle maintained good performance. (author)

  1. Sleeve Gastrectomy and Roux-en-Y Gastric Bypass Alter the Gut-Brain Communication

    Directory of Open Access Journals (Sweden)

    L. A. Ballsmider

    2015-01-01

    Full Text Available This study investigated the anatomical integrity of vagal innervation of the gastrointestinal tract following vertical sleeve gastrectomy (VSG and Roux-en-Y gastric bypass (RYGB operations. The retrograde tracer fast blue (FB was injected into the stomach to label vagal neurons originating from nodose ganglion (NG and dorsal motor nucleus of the vagus (DMV. Microglia activation was determined by quantifying changes in the fluorescent staining of hindbrain sections against an ionizing calcium adapter binding molecule 1 (Iba1. Reorganization of vagal afferents in the hindbrain was studied by fluorescent staining against isolectin 4 (IB4. The density of Iba1- and IB4-immunoreactivity was analyzed using Nikon Elements software. There was no difference in the number of FB-labeled neurons located in NG and DMV between VSG and VSG-sham rats. RYGB, but not RYGB-sham rats, showed a dramatic reduction in number of FB-labeled neurons located in the NG and DMV. VSG increased, while the RYGB operation decreased, the density of vagal afferents in the nucleus tractus solitarius (NTS. The RYGB operation, but not the VSG procedure, significantly activated microglia in the NTS and DMV. Results of this study show that the RYGB, but not the VSG procedure, triggers microglia activation in vagal structures and remodels gut-brain communication.

  2. Microcirculatory Improvement Induced by Laparoscopic Sleeve Gastrectomy Is Related to Insulin Sensitivity Retrieval.

    Science.gov (United States)

    Ministrini, Stefano; Fattori, Chiara; Ricci, Maria Anastasia; Bianconi, Vanessa; Paltriccia, Rita; Boni, Marcello; Paganelli, Maria Teresa; Vaudo, Gaetano; Lupattelli, Graziana; Pasqualini, Leonella

    2018-05-12

    Microvascular dysfunction is a potential factor explaining the association of obesity, insulin resistance, and vascular damage in morbidly obese subjects. The purpose of the study was to evaluate possible determinants of microcirculatory improvement 1 year after laparoscopic sleeve gastrectomy (LSG) intervention. Thirty-seven morbidly obese subjects eligible for bariatric surgery were included in the study. Post-occlusive reactive hyperemia (PORH) of the forearm skin was measured as area of hyperemia (AH) by laser-Doppler flowmetry before LSG and after a 1-year follow-up. After intervention, we observed a significant reduction in BMI, HOMA index, HbA1c, and a significant increase of AH in all patients after surgery; this variation was significant only in those patients having insulin resistance or prediabetes/diabetes. Although significant correlation between the increase of AH and the reduction of both BMI, HOMA index, and HbA1c was observed, BMI was the only independent predictor of AH variation after LSG at the linear regression analysis. Our study shows that LSG intervention is correlated with a significant improvement in the microvascular function of morbidly obese subjects; this improvement seems to be related to the baseline degree of insulin-resistance and to the retrieval of insulin-sensitivity post-intervention.

  3. Double-nippled ureteroneocystostomy: a novel surgical technique in ...

    African Journals Online (AJOL)

    The lowest segment of the dilated obstructed ureter is transected and passed through the bladder dome for ureterovesical implantation. The distal 3 cm is folded twice like a sleeve to fashion a double-nippled valve. Evaluation of the appearance and function of the ureter and ipsilateral renal function was done by laboratory, ...

  4. The influence of laparoscopic adjustable gastric banding and laparoscopic sleeve gastrectomy on weight loss, plasma ghrelin, insulin, glucose and lipids

    Directory of Open Access Journals (Sweden)

    Hady Razak Hady

    2012-07-01

    Full Text Available The aim of this study was to assess the impact of laparoscopic gastric banding and laparoscopic sleeve gastrectomy on the concentration of ghrelin, insulin, glucose, triglycerides, total and HDL-cholesterol, as well as AST and ALT levels in plasma in patients with obesity. The research includes 200 patients operated using LAGB (34 men average age 37.0 ± 12.6 years and 66 women average age 39.18 ± 12.17 years and LSG (48 men average age 47.93 ± 9.24 years and 52 women, 19 ± 9.33 years. The percentage of effective weight loss, effective BMI loss, concentration of ghrelin, insulin, glucose, triglycerides, total cholesterol, HDL-cholesterol, LDL-cholesterol, ALT, AST and HOMA IR values was taken preoperatively and at 7th day, 1 month, 3 and 6 months after surgery. Both after LSG and after LAGB, statistically significant reduction in BMI, serum insulin, glucose and HOMA IR was noticed in comparison to the preoperative values. Post LAGB, patients showed an increase of ghrelin, while LSG proved ghrelin decreased. Correlations between glucose and BMI loss, and between insulin and BMI loss in both cases are more favorable in the LSG group. Lipid parameters, AST and ALT have undergone declines or  increases in the particular time points. Both techniques cause weight loss and this way lead to changes in the concentration of ghrelin, as well as to the improvement of insulin, glucose, cholesterol and triglycerides metabolism. They reduce metabolic syndrome and multiple comorbidities of obesity.

  5. DEFINITION OF DENSITY OF THE THERMAL STATIONARY STREAMS ON A SURFACES OF A SLEEVE OF CYLINDER COMBUSTION ENGINE BY A METHOD OF OPTIMUM FILTRATION KALMANA

    Directory of Open Access Journals (Sweden)

    ZARENBIN V. G.

    2016-01-01

    Full Text Available Problem statement. At research warmly intensity and thermal weariness of internal combustion engines (ICE the knowledge and the analysis of local temperatures and thermal streams in the basic details forming the chamber of combustion is defining. Theoretically the problem consists in the decision of the equation of heat conductivity at the set features of course of thermal processes on border of bodies. Thus there is a problem of accuracy of the decision since it depends on accuracy of the task of real boundary conditions which can be received only by means of physical experiment and corresponding metrological maintenance. Unlike temperature the thermal stream cannot be measured directly, therefore it define on a difference of temperatures (thermal gradient a method or a calorimetric method. Definition of density of streams with the help as named gauges of a thermal stream when the measured temperatures are used at the decision of a return problem of heat conductivity for chosen thermometric an element is most extended. In this case, except the requirement of one-dimensionality of distribution of temperatures, linearity and the minimum distortion of temperature fields of thermal system, there are considerable difficulties of calculation derivative of the measured temperature. To perspective it is possible to carry methods of researches which it is accepted to name cybernetic diagnostics or identification of systems. Their essence consists that the deformed information on object is compared to its mathematical model and then are defined its condition, parameters or entrance influences by minimization of square-law function are nonviscous. In work definition of density of thermal stationary streams on surfaces of a sleeve of cylinder ICE by a method of optimum filtration Kalmana and also an estimation of their reliability and accuracy is made. Possibility of application of filtration Kalmana is shown at experimental researches in ICE. The purpose

  6. Sleeve gastrectomy severe complications: is it always a reasonable surgical option?

    Science.gov (United States)

    Moszkowicz, David; Arienzo, Roberto; Khettab, Idir; Rahmi, Gabriel; Zinzindohoué, Franck; Berger, Anne; Chevallier, Jean-Marc

    2013-05-01

    Laparoscopic sleeve gastrectomy (LSG) is widely adopted but exposes serious complications. A retrospective database analysis was done to study LSG staple line complications in a tertiary referral university center with surgical ICU experienced in treatment of morbid obesity and complications. Twenty-two consecutive patients were referred between January 2004 and February 2012 with postoperative gastric leak or stenosis after LSG. Interventions consisted in the control of intra-abdominal and general sepsis; restoration of staple line continuity or revision of LSG; nutritional support; treatment of associated complications. Main outcome measures concerned success rates of therapeutic strategies, morbidity and mortality rates, LOS, and time to cure. Thirteen patients (59 %) were referred after failure of reoperation (seven fistula repairs were attempted). Three patients received emergency surgery in our center with transorificial intubation and jejunostomy formation. An endoscopic stent was tried in nine patients but failed in 84.6 % of cases within 20 days (1-161). Seven patients (32 %) necessitated total gastrectomy within 217 days (0-1,915 days) for conservative treatment failure. Procedures under general anesthesia were required in 41 % of cases, organ failure was found in 55 % of cases, and central venous device infection in 40 %. Mortality rate was 4.5 % (n = 1). Patients with unfavorable evolution of LSG complications (death or additional gastrectomy) had more previous bariatric procedure (82 % vs. 18 %, p = 0.003). Median time to cure was 310 days (9-546 days). LSG exposes severe complications occurring in patients with benign condition. Endoscopic stents entail high failure rate. Total gastrectomy is required in one third of the cases.

  7. Alcohol consumption after laparoscopic sleeve gastrectomy: 1-year results.

    Science.gov (United States)

    Coluzzi, Ilenia; Iossa, Angelo; Spinetti, Elena; Silecchia, Gianfranco

    2018-02-06

    Laparoscopic sleeve gastrectomy (SG) represents, at present, the most performed bariatric procedure worldwide with excellent long-term results on weight loss and comorbidities control. After the gastrectomy procedure, together with hormonal modification, several changes in taste and habits occur, including the potential modification in alcohol consumption. The aim of this prospective study was to determine the frequency and the amount of alcohol use before and after SG using a modified version of the Alcohol Use Disorder Identification Test (AUDIT) at 1-year follow-up and eventually to evaluate relationships between different ages and sexes. A total of 142 patients were prospectively enrolled and evaluated before and 1 year after SG with a modified AUDIT. The exclusion criteria were as follows: history of alcohol abuse, presence of psychopathology or cognitive impairments, diabetes mellitus type II decompensated, or previous gastrointestinal, liver, and pancreatic resective surgery. Subgroup analyses were performed between male and female and between under and over 40 years old. The median AUDIT score decreased from 2.70 (range 1-18) before surgery to 1.38 (range 1-7) after 1 year of SG, indicating a marked reduction in alcohol use. The most consumed alcoholic drink was beer (36.6%/n = 52) while after surgery the consumption of beer decreased considerably (21.1%/n = 30). The frequency of alcohol consumption also decreased: at baseline 45% of patients consumed alcoholic drinks "from 2 to 4 times per month", whereas 26 and 39.4% consumed alcohol "never" and "less than once a month," respectively. After surgery, nobody consumed more then six alcoholic drinks. No differences were found between the subgroups in terms of alcohol consumption and social behavior. The alcohol preference is modified and decreased 1 year after SG and this could be related to the strict nutritional follow-up and to the hormonal changes. Studies with large samples and long

  8. Refinement of Perioperative Feeding in a Mouse Model of Vertical Sleeve Gastrectomy.

    Science.gov (United States)

    Doerning, Carolyn M; Burlingame, Lisa A; Lewis, Alfor G; Myronovych, Andriy; Seeley, Randy J; Lester, Patrick A

    2018-05-01

    Provision of liquid enteral nutrition (LEN) during the perioperative period is standard practice for rodents undergoing bariatric surgery, yet these diets are associated with several challenges, including coagulation of the liquid diet within the delivery system and decreased postoperative consumption. We investigated the use of a commercially available high-calorie dietary gel supplement (DG) as an alternative food source for mice during the perioperative period. C57BL/6J male mice were fed high-fat diet for 8 to 10 wk prior to surgery. The study groups were: vertical sleeve gastrectomy (VSG) +DG, VSG+LEN, sham surgery+DG, and sham+LEN. Food and water intakes, body weight, and body fat composition was monitored throughout the study. Mice that received DG lost significantly more weight preoperatively than those fed LEN. However, during the postoperative period, body weight, body fat composition, and water and caloric intake were similar among all experimental diet groups. Three mice in the VSG+LEN group were euthanized due to clinical illness during the course of the study. In summary, feeding a high-calorie DG to mice undergoing VSG surgery is a viable alternative to LEN, given that DG does not significantly affect the surgical model of weight loss or result in adverse clinical outcomes. We recommend additional metabolic characterization of DG supplementation to ensure that this novel diet does not confound specific research goals in the murine VSG model.

  9. Effects of Weight Reduction After Sleeve Gastrectomy on Metabolic Variables in Saudi Obese Subjects in Aseer Province of Kingdom of Saudi Arabia.

    Science.gov (United States)

    Bawahab, Mohammed A; Assiri, Abdullah S; Maksoud, Walid Abdel; Patel, Ayyub; Kadoumi, Osama; Zaman, Gaffar Sarwar; Alessih, Riyad Mohammed Khalil; Haider, Syed Saleem

    2017-08-01

    The objectives of this study were to investigate the occurrence of oxidative stress, status of protective antioxidants enzymes, inflammatory biomarkers, and some metabolic health variables in the blood and to compare the results between those of the normal controls and obese patients submitted to sleeve gastrectomy-induced weight loss over a 1-year follow-up period. A prospective study was conducted in Aseer Central Hospital and Abha Private Hospital in the Kingdom of Saudi Arabia from January 2012 to January 2013 on 50 normal (BMI = 22-25 kg/m 2 ) control subjects and 50 obese (BMI = 45-50 kg/m 2 ) patients. A subset of 20 men and 80 women patients, aged 20-45 years, was included. The systemic blood cell counts were determined by Beckman Coulter UniCel analyzer. The occurrence of oxidative stress, the status of antioxidant enzyme system in the blood, levels of serum hepatic enzymes, cardiovascular risk factors, and serum sodium, potassium, copper, and zinc levels were determined by spectrophotometric procedures. The concentration of TSH and T 4 were analyzed by Siemens Immunoassay System. Group 1 (Obese: preoperative) This group compared with the normal controls exhibited significant (p copper and zinc levels were significantly (p phosphate dehydrogenase (G6PDH), and vitamin C, were remarkably (p potassium, copper, zinc, and TSH levels were significantly (p < 0.001) decreased. Obesity is a chronic disease of multifactorial origin and resulted in perturbations of whole body metabolism in this study. It is thus likely that this imbalance was associated with an inhibition in protective antioxidants and occurrence of oxidative stress. The staging concept of sleeve gastrectomy is a safe and effective approach with remarkable efficacy in sustaining weight loss and bringing back normal metabolism of variables in tissues over a 1-year follow-up period.

  10. Standards for pipelines repairs approval through composite sleeves materials; Criterios para aceitacao de reparos em dutos atraves de luvas de material composito

    Energy Technology Data Exchange (ETDEWEB)

    Bayer, Richard Foerster; Bifulco, Antonio C.; Vilani, Eduardo C. [Rust Engenharia Ltda., Diadema, SP (Brazil)

    2005-07-01

    The current paper presents the standards that define the test demanded by the technical specifications set for the evaluation of composite sleeves repairs for steel industrial ducts and pipelines, as well as their forecasted results. Practical comments are given about the adhesion, tensile strength, interlaminate shear resistance, impact, hardness, circumferential elasticity modulus, axial elasticity modulus, and the poison ratio rests, as well as the interpretation of those demands are also discussed. Explains the repair project and the procedure to be followed importance, and why qualified personnel are necessary to install it. The repair project and the procedure, as well as the repair construction effectiveness are verified by hydrostatics testes in tubular specimens. (author)

  11. Comparison of the Effect of Gastric Bypass and Sleeve Gastrectomy on Metabolic Syndrome and its Components in a Cohort: Tehran Obesity Treatment Study (TOTS).

    Science.gov (United States)

    Barzin, Maryam; Motamedi, Mohammad Ali Kalantar; Serahati, Sara; Khalaj, Alireza; Arian, Peyman; Valizadeh, Majid; Khalili, Davood; Azizi, Fereidoun; Hosseinpanah, Farhad

    2017-07-01

    Metabolic syndrome (MetS) is a prevalent counterpart of morbid obesity. With the surgical technique of sleeve gastrectomy (SG) gaining widespread acceptance for weight loss in morbid obese patients, we aimed to undertake a study to compare its effectiveness to gastric bypass (GB) for metabolic control in these patients. A total of 425 patients from a prospectively collected database of morbid obese subjects between 18 and 65 years of age undergoing a primary bariatric procedure from March 2013 to September 2015 were included. Statistical analysis was performed using general estimation equation and propensity scores, and odds ratios were calculated. Three hundred nineteen patients underwent SG and 106 underwent GB. Mean age of the patients was 37.8 ± 11.7, and mean body mass index (BMI) was 44.3 ± 5.9 kg/m 2 . MetS was present in 61.4% of patients and diabetes mellitus in 48.6%. MetS prevalence decreased from 60 and 64% in the SG and GB groups to 16 and 10% at 12 months, respectively. These improvements were consistent throughout the study period in both groups, with no significant difference between the two groups (for all variables: P trend   .05). After propensity score-adjusted analysis, neither surgical technique showed superiority over the other regarding metabolic improvement (OR for MetS resolution: 0.81, 95% CI: 0.49-1.34). In this short-term study with 1-year follow-up, SG showed similar results to GB in terms of weight loss, MetS resolution, and glycemic control in a large Middle Eastern cohort. Long-term studies are needed to further investigate the effectiveness of SG in this regard.

  12. Port site hernia after laparoscopic sleeve gastrectomy: a retrospective cohort study of 352 patients.

    Science.gov (United States)

    Ece, Ilhan; Yilmaz, Huseyin; Alptekin, Husnu; Yormaz, Serdar; Colak, Bayram; Sahin, Mustafa

    2018-03-01

    Port site hernia (PSH) following laparoscopic procedures is a rare but serious complication. The aim of this study was to evaluate the rate of PSH after laparoscopic sleeve gastrectomy (LSG), and the efficacy of closure of the port site as a means of preventing PSH. A retrospective analysis was performed on 386 patients who underwent LSG between December 2009 and January 2015. 352 (91.2%) of the patient were followed up for at least 24 months. In the first 206 patients, the fascial layers of the trocar incisions were not closed, while in the next 146 cases, routine closure of the trocar sites was performed. The patients were reviewed in relation to demographics, comorbidities, complications, percentage of excess weight loss, and rates of PSH. The total cohort consisted of 220 female and 132 male patients with a mean age of 36.2 ± 12.3 years. Demographic data, initial BMI, and comorbidities were similar for the patients in both groups. The closure of the fascia was caused by the prolonged duration of the operation with no significant difference. The unclosed fascial defects were associated with a significantly increased incidence of PSH (1.3 vs. 3.9%, p port sites may result in a decreased PSH rate.

  13. Sugammadex versus two doses of neostigmine for reversal of rocuronium in gastric sleeve surgery

    Directory of Open Access Journals (Sweden)

    Abdulhamid Alsaeed

    2017-01-01

    Patients and Methods: A total of 110 patients with body mass index> 40 underwent elective gastric sleeve surgery were enrolled in this study. Exclusion criteria included patients with co-existing muscular and cardiovascular diseases. Patients were randomly allocated to one of the following groups: group A (SUG, Group B (NEO 2.5 mg, and Group C (NEO 5 mg. General anesthesia was induced in the three groups using propofol 2.0 mg/kg of corrected body weight (CBW and fentanyl 3 mcg/kg of CBW. Anesthesia was maintained with O2/air/desflurane 1 minimum alveolar concentration. Remifentanil infusion started at 0.05–0.2 mcg/kg/min. Tracheal intubation was facilitated with rocuronium 1.2 mg/kg of CBW guided with PNS. When the train of four (TOF reached zero, intubation was performed using a GlideScope. At the end of surgery, TOF ratio and posttetanic counts were recorded. SUG 2 mg/kg of CBW (Group A, NEO 2.5 mg (Group B, and NEO 5 mg (Group C were administered according to the random envelope. The time to achieve 90% of TOF was recorded in seconds using a timer. ANOVA for repeated measurements was used for statistical analyses. P 90%, the recovery pattern of both was similar.

  14. Contrasting Sleeve Gastrectomy with Lifestyle Modification Therapy in the Treatment of Polycystic Ovary Syndrome.

    Science.gov (United States)

    Wang, Kaijing; Jiang, Qixin; Zhi, Yunqing; Zhu, Zhe; Zhou, Zhuqing; Xie, Yanting; Yin, Xiaoqi; Lu, Aiguo

    2015-06-01

    To explore the feasibility of sleeve gastrectomy (SG) as a treatment for polycystic ovary syndrome (PCOS) and its potential to improve clinical efficacy in PCOS patients with symptoms of oligomenorrhea. Twenty-four obese patients with PCOS underwent laparoscopic SG. Simultaneously, 24 obese patients with PCOS received lifestyle modification therapy (LMT). Follow-ups were conducted at 3-6 months. Weight loss, menstruation, and improvements in hirsutism and metabolic symptoms were compared. In the SG group, 20 patients were restored to normal menstrual cycles and ovulation at 3-6 months after surgery. Their average androgen levels decreased significantly following surgery (P=.012). Conversely, only 6 patients in the LMT group were restored to normal menstrual cycles and ovulation after receiving 3 months of treatment. Their average preoperative and postoperative androgen levels showed a nonstatistically significant decrease (P>.05). Compared with the LMT group, the SG group showed more pronounced improvements in menstruation. Additionally, body mass and body mass index were significantly reduced in patients in the SG group 3 months after the surgeries, with maximum weight loss observed at approximately 6 months after surgery. Patients who received LMT showed a gradual weight reduction such that body mass decreased significantly after 3 months (Pweight loss results (Pweight loss and better improvements in clinical symptoms compared with LMT.

  15. Improvement technique of sensitized HAZ by GTAW cladding applied to a BWR power plant

    International Nuclear Information System (INIS)

    Tujimura, Hiroshi; Tamai, Yasumasa; Furukawa, Hideyasu; Kurosawa, Kouichi; Chiba, Isao; Nomura, Keiichi.

    1995-01-01

    A SCC(Stress Corrosion Cracking)-resistant technique, in which the sleeve installed by expansion is melted by GTAW process without filler metal with outside water cooling, was developed. The technique was applied to ICM (In-Core Monitor) housings of a BWR power plant in 1993. The ICM housings of which materials are type 304 Stainless Steels are sensitized with high tensile residual stresses by welding to the RPV (Reactor Pressure Vessel). As the result, ICM housings have potential of SCC initiation. Therefore, the improvement technique resistant to SCC was needed. The technique can improve chemical composition of the housing inside and residual stresses of the housing outside at the same time. Sensitization of the housing inner surface area is eliminated by replacing low-carbon with proper-ferrite microstructure clad. High tensile residual stresses of housing outside surface area is improved into compressive side. Compressive stresses of outside surface are induced by thermal stresses which are caused by inside cladding with outside water cooling. The clad is required to be low-carbon metal with proper ferrite and not to have the new sensitized HAZ (Heat Affected Zone) on the surface by cladding. The effect of the technique was qualified by SCC test, chemical composition check, ferrite content measurement and residual stresses measurement etc. All equipment for remote application were developed and qualified, too. The technique was successfully applied to a BWR plant after sufficient training

  16. Circulating adiponectin increases in obese women after sleeve gastrectomy or gastric bypass driving beneficial metabolic changes but with no relationship with carotid intima-media thickness.

    Science.gov (United States)

    Gómez-Martin, Jesús M; Balsa, José A; Aracil, Enrique; Insenser, María; Priego, Pablo; Escobar-Morreale, Héctor F; Botella-Carretero, José I

    2017-10-12

    Obesity surgery induces beneficial effects in metabolic and cardiovascular parameters. Adiponectin increase might be associated with some of these changes. However, direct comparison between different surgical techniques has not been extensively performed. We studied 20 obese women submitted to laparoscopic Roux en Y gastric bypass (RYGB) and 20 to sleeve gastrectomy (SG). Twenty control women matched for age and baseline metabolic profiles were also included. Both patients and controls were followed up for one year after surgery or conventional treatment with diet and exercise, respectively. Serum adiponectin was measured at baseline, 6 months and 1 year after, as well as lipid profiles, sex hormone binding globulin (SHBG), fasting glucose and insulin. Carotid intima-media thickness was measured by ultrasonography at baseline and after 1 year. Circulating adiponectin increased after obesity surgery (more markedly following RYGB than after SG), whereas no changes were observed in the controls (Wilks' λ = 0.659, P media thickness (r = -0.055, P = 0.679). RYGB induces a higher increase in adiponectin than SG, which parallels SHBG, the reduction of fasting insulin and insulin resistance. On the other hand, no association was found with carotid intima-media, lipid profiles or blood pressure. Copyright © 2017 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  17. Behaviour of a pressure vessel nozzle with thermo-sleeve under thermal loading induced by stratified flow

    International Nuclear Information System (INIS)

    Kussmaul, K.; Mayinger, W.; Diem, H.; Katzenmeier, G.

    1993-01-01

    Startup at low reactor power may give rise to stratified flow conditions in pipes of boiling water and pressurized water reactors. Stratified flow regimes cause a steep temperature gradient between the cold and the hot fluid layer. This temperature gradient produces high axial stresses which, in the case of intermittent feeding of cold water and an appropriate number of repetitions, in principle may initiate cracking in the feedwater pipe and close to the feeding nozzle. Thermosleeves have been installed in a number of reactors to mitigate thermally induced stresses; they reduce the intensity of thermal transients by means of an insulating fluid annulus developing between the sleeve and the nozzle, in order to measure the temperature and stress gradients occurring in the region of the nozzle edge, the so-called TEMS experiments were carried out under realistic operating conditions, and with different cold water levels within the framework of German research activities in the field of reactor safety at the HDR test facility. The experiments served to simulate the physics phenomena by means of a FE-program and to verify the computational approach by comparisons of measurements and calculations

  18. Staple Line Reinforcement with Stitch in Laparoscopic Sleeve Gastrectomies. Is It Useful or Harmful?

    Science.gov (United States)

    Albanopoulos, Konstantinos; Tsamis, Dimitrios; Arapaki, Aggeliki; Kleidi, Eleftheria; Zografos, Georgios; Leandros, Emmanouil

    2015-07-01

    Reinforcement of the staple line in laparoscopic sleeve gastrectomy (LSG) is a practice that leads to less morbidity, but equivocal results have been reported in the literature. This is a prospective randomized study comparing two groups of patients who underwent LSG. In one group LSG was performed with a running absorbable suture placement at the staple line. In the other group the running suture was not placed. General data of the patients, as well as intraoperative and postoperative data, were gathered and statistically analyzed. Overall, 146 patients were subjected to LSG. In 84 patients a running suture was placed, and in 62 patients no suture was placed. No significant differences were found between the two groups in demographic data. No significant differences were found also in the intraoperative data, such as number of trocars, number and type of cartridges, drain placement, and operative time (45±21 versus 40±20 minutes, respectively; Prunning suture (9.5% versus 0.0%, respectively; P.05). After this randomized study, final conclusions about the efficacy of this running suture to the staple line cannot be made. To the contrary, problems seem to exist after such reinforcement of the staple line, such as hematomas. Dealing with possible leaks and hemorrhage of the staple line is also problematic after placement of the running suture.

  19. Chores at Times of Fatal or Serious Injuries Associated with Tractor Overturns with and without Rollover Protection

    Directory of Open Access Journals (Sweden)

    Henry P. Cole

    2016-09-01

    Full Text Available This study describes chores when farmers were either fatally or seriously injured and required emergency medical treatment as a result of overturns of tractors with or without rollover protective structures (ROPS. Data from the 2002 Kentucky Farm Tractor Overturn Survey were used for this study. The data were collected by a telephone survey of a population-based random sample of 6063 (7.98% of Kentucky’s 76,017 farm operators as listed in the Kentucky Agricultural Statistics Service database. Of farm operators interviewed, 551 (9.1% reported 603 overturns and 5512 (90.9% reported no overturns in the history of their farm, covering a period from 1925 to February 2002. Only the latest overturn was considered to improve recall accuracy. In addition, since the 1925 to 1959 time period had only 49 (8.1% of the overturns reported, (14 farmers did not provide the year of most recent overturn; only data from the 1960 to 2002 period (approximately 41 years were used. After making these adjustments, incidents evaluated included 25 cases (one fatal and four serious nonfatal injuries that involved ROPS-equipped tractor overturns and 88 cases (24 fatal and 64 serious nonfatal injuries that involved non-ROPS tractor overturns. Chores at highest risk for tractor overturns were identified for which educational and ROPS retrofit interventions could be emphasized. The highest frequency of overturn-related fatalities and nonfatal injuries were associated with hay harvesting, rotary mowing, and on-farm travel chores. These three chores represented 68.2% of fatal events and 50.0% of permanent and 56.6% of temporary disability overturn incidents. Tragically, in countries such as India and China with emerging mechanization, a large majority of tractors are produced without ROPS that can be expected to result in the same overturn-related epidemic of deaths experienced in highly mechanized countries, despite evidence of the protection provided by ROPS.

  20. Ten-year rollover of San Onofre inservice testing program for pumps and valves to OM-6 and OM-10

    International Nuclear Information System (INIS)

    Croy, P.A.; Fischetti, S.; Chiang, D.; Schofield, P.; Barney, D.

    1994-01-01

    The Pump and Valve Inservice Testing (IST) Program Sat San Onofre, Units 2 and 3, was updated for the second 120-month interval from August 1993 to April 1994. The U.S. Nuclear Regulatory Commission (USNRC) approved the OM-6 and OM-10 Codes in mid-1992. The project for the rollover to these new Codes included several elements: (a) a review of the differences between IWV/IWP and OM-6/OM-10, (b) a comprehensive audit of the IST Program scope for valves, (c) creation of the program and supporting basis documents, the Relief Requests, and implementing procedures, (d) interdivisional coordination, (e) submittal to the USNRC, and (f) training. Subsections IWV and IWP have been used and essentially unchanged for over a decade. The new Code (Parts 1, 6, and 10 called OM-1, OM-6, and OM-10) includes several significant changes from the old Code. Our group identified these differences and drafted revised and reorganized Inservice Testing (IST) Program documents. We also considered USNRC Generic Letter 89-04 (GL 89-04), open-quotes Guidance on Developing Acceptable Inservice Testing Programsclose quotes, and NUREG-1482, Guidelines for Inservice Testing at Nuclear Power Plants, while revising the program. There were six pump relief requires and 13 valve relief requests in the program for the first 10-year interval. For the revised program we needed only one pump relief request (and no valve relief requests). Converting to the 1989 edition of the ASME Code did not require changes to the technical specifications. We revised our Updated Final Safety Analysis Report (UFSAR) to reflect the IST Program for the second 10-year interval. UFSAR changes were minor, consisting of updated references to the Code edition and 10 CFR 50.55a(f), open-quotes Inservice Testing Requirementsclose quotes

  1. [A case of iatrogenic scrotal elephantiasis: reconstruction of the scrotal purse and the cutaneous sleeve of the penis with local skin flaps].

    Science.gov (United States)

    Masia, D-R; Castus, P; Delia, G; Casoli, V; Martine, D

    2008-02-01

    Scrotal elephantiasis is a pathology of often unknown etiology. Symptomatology is characterized by an oedematius infiltration of skin and subcutaneous tissue, hard-bound aspect and purplished color. The scrotum, the penis and the perineal area are gradually affected. This pathology is very invalidating for the patient, on functional, sexual and aesthetic aspects. The authors present the case of a 58-year-old man with an enormous scrotal mass invading the penis and drowning the testicular elements, which were impossible to palpate. The aetiology was determined by exclusion and an iatrogenic origin following the cure of bilateral inguinal hernia was retained. Resection of the scrotal mass was performed. The reconstruction of the scrotal purse and the cutaneous sleeve of the penis were carried out using local flaps of the remaining healthy skin.

  2. New Car Assessment Program (NCAP) - 5 Star Safety Ratings

    Data.gov (United States)

    Department of Transportation — NCAP rates vehicles to determine crash worthiness and rollover safety. The safety ratings are gathered during controlled crash and rollover tests conducted at NHTSA...

  3. Predictors of fat-free mass loss 1 year after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Guida, B; Cataldi, M; Busetto, L; Aiello, M L; Musella, M; Capone, D; Parolisi, S; Policastro, V; Ragozini, G; Belfiore, A

    2018-03-24

    Laparoscopic sleeve gastrectomy (LSG) is one of the most frequently performed bariatric surgery interventions because of its safety and efficacy. Nevertheless, concerns have been raised on its detrimental effect on patient nutritional state that can ultimately lead to the loss of fat-free mass (FFM). There is interest in identifying predictors for the early identification of patients at risk of this highly unwanted adverse because they could benefit of nutritional preventive interventions. Therefore, we investigated whether anthropometric parameters, body composition or resting energy expenditure (REE) measured before surgery could predict FFM loss 1 year after LSG. Study design was retrospective observational. We retrieved data on body weight, BMI, body composition and REE before and 1 year after LSG from the medical files of 36 patients operated on by LSG at our institutions. Simple regression, the Oldham's method and multilevel analysis were used to identify predictors of FFM loss. Averaged percentage FFM loss 1 year after LSG was 17.0 ± 7.7% with significant differences between sexes (20.8 ± 6.6 in males and 12.2 ± 6.1% in females, p FFM loss was strongly predicted by pre-surgery FFM and this effect persisted also after correcting for the contribution of sex. High FFM values before surgery predict a more severe FFM loss after LSG. This factor could also account for the higher FFM loss in men than in women. Our finding could help in the early identification of patient requiring a nutritional support after LSG.

  4. Nuclear fuel assembly grid sleeve/guide thimble bulge orientation gage and inspection method

    International Nuclear Information System (INIS)

    Widener, W.H.

    1988-01-01

    This patent describes a method of inspecting a fuel assembly to determine the orientation of externally-projecting mated bulges connecting a grid sleeve to a guide thimble of the assembly, the method comprising the steps of: (a) inserting a radially-expandable tubular member within the guide thimble, the tubular member having externally-projecting embossments thereon spaced circumferentially from one another about the tubular member, the embossments being the same in number as the bulges of the guide thimble and configured to fit therewithin; (b) axially moving an elongated expansion member, which extends through and rotatably mounts the tubular member, relative to the tubular member from a first position in which the expansion member permits inward contraction of the tubular member and displacement of embossments thereon away from the interior of the guide thimble bulges for removing the embossments from registry therewith and a second position in which the expansion member produces radial expansion of the tubular member and displacement of the embossments thereon toward the interior of the guide thimble bulges for placing the embossments in registry therewith; (c) rotating the tubular member relative to the expansion member so as to bring the embossments on the tubular member into alignment with the guide thimble bulges as the embossments on the tubular member are being displaced toward and into registry with the interior of the bulges; and (d) responsive to rotation of the tubular member away from a reference position, providing an indication of the orientation of the guide thimble bulges relative to a reference point upon displacement of the embossments into registry therewith

  5. C-reactive protein, fibrinogen, and procalcitonin levels as early markers of staple line leak after laparoscopic sleeve gastrectomy in morbidly obese patients within an Enhanced Recovery After Surgery (ERAS) program.

    Science.gov (United States)

    Ruiz-Tovar, Jaime; Muñoz, Jose Luis; Gonzalez, Juan; Garcia, Alejandro; Ferrigni, Carlos; Jimenez, Montiel; Duran, Manuel

    2017-12-01

    The performance of most bariatric procedures within an Enhanced Recovery After Surgery program has resulted in significant advantages, including a reduction in the length of hospital stay to 2-3 days. However, some postoperative complications may appear after the patient has been discharged. The aim of this study was to investigate the efficacy of various acute-phase parameters determined 24 h after a laparoscopic sleeve gastrectomy for predicting staple line leak in the postoperative course. A prospective study of 208 morbidly obese patients undergoing laparoscopic sleeve gastrectomy as bariatric procedure between 2012 and 2015 was performed. Blood analysis was performed 24 h after surgery. Acute-phase parameters (C-reactive protein, procalcitonin, fibrinogen, and White Blood Cell count) were investigated. Staple line leak appeared in eight patients (3.8%). Using receiver operating characteristic analysis at 24 h postoperatively, a cutoff level of CRP at 9 mg/dL achieved 85% sensitivity and 90% specificity for predicting staple line leak, a cutoff level of procalcitonin at 0.85 ng/mL achieved 70% sensitivity and 90% specificity, and a cutoff level of fibrinogen at 600 mg/dL achieved 80% sensitivity and 87.5% specificity. An elevation of CRP > 9 mg/dL, procalcitonin > 0.85 ng/mL and fibrinogen > 600 mg/dL should alert the surgeon the possibility of occurrence of postoperative staple line leak.

  6. Laparoscopic Sleeve Gastrectomy for Morbid Obesity in Patients After Orthotopic Liver Transplant: a Matched Case-Control Study.

    Science.gov (United States)

    Tsamalaidze, Levan; Stauffer, John A; Arasi, Lisa C; Villacreses, Diego E; Franco, Jose Salvador Serrano; Bowers, Steven; Elli, Enrique F

    2018-02-01

    Obesity is frequently encountered in patients with orthotopic liver transplant (OLT). The role of bariatric surgery is still unclear for this specific population. The aim of this study was to review our experience with laparoscopic sleeve gastrectomy (LSG) after OLT. We performed a retrospective case-control study of patients undergoing LSG after OLT from 2010 to 2016. OLT-LSG patients were matched by age, sex, body mass index (BMI), and year to non-OLT patients undergoing LSG. Demographics, operative variables, postoperative events, and long-term weight loss with comorbidity resolution were collected and compared between cases and controls. Of 303 patients undergoing LSG, 12 (4%) had previous OLT. They were matched to 36 non-OLT patients. No difference was found between groups in the American Society of Anesthesiologists class, mean operative time, or postoperative morbidity. The non-OLT group, however, had a significantly shorter mean hospital stay than the OLT group (1.7 vs 3.1 days; P OLT patients had significantly more excess body weight loss at 2 years (53.7 vs 45.2%; P OLT in appropriately selected patients appears to have similar outcomes to LSG in non-OLT patients.

  7. Diet Change After Sleeve Gastrectomy Is More Effective for Weight Loss Than Surgery Only.

    Science.gov (United States)

    Rossell, Joana; González, Marta; Mestres, Núria; Pardina, Eva; Ricart-Jané, David; Peinado-Onsurbe, Julia; Baena-Fustegueras, Juan Antonio

    2017-10-01

    Bariatric surgery with or without diet change has become one of the most effective treatments for obesity. The objective of this study was to observe the effects of vertical sleeve gastrectomy (VSG) and diet change in Sprague-Dawley rats on both body and tissue weights. Eighteen rats were fed with a standard chow diet (SCD) (C group), and 36 rats were fed with a high-fat diet (HFD) (diet-induced obesity (DIO) group). After 8 weeks, the animals underwent VSG, sham surgery or no surgery (NS). After surgery, a third of the rats fed with the HFD changed to the SCD (DIO + C group). Body weight, food and energy intake were recorded daily during the experiment (12 weeks). Food efficiency (%) (FE) was determined from weekly weight gain and weekly kilocalorie consumed measurements. The DIO group had higher and significant weight gain than the C group at the time of surgery (p weight loss (WL) was observed in the DIO + C-VSG group, during the 4 weeks after surgery. Adipose tissues in the DIO + C-VSG group were drastically reduced and had a weight similar to those in the C-VSG group. VSG and the diet change combination led to a greater WL, which was maintained during the 4 weeks post-surgery, leading to a normalization of body weight. VSG and diet change also affected most of the tissues, not only adipose, showing a global change in whole body composition.

  8. Randomized, Prospective Comparison of Ursodeoxycholic Acid for the Prevention of Gallstones after Sleeve Gastrectomy.

    Science.gov (United States)

    Adams, Lindsay B; Chang, Craig; Pope, Janet; Kim, Yeonsoo; Liu, Pei; Yates, Amy

    2016-05-01

    Several studies have examined the role of ursodeoxycholic acid (UDCA) for the prevention of cholelithiasis (gallstones) following rapid weight loss from restrictive diets, vertical band gastroplasty, and Roux-en-Y gastric bypass. However, to date, there have been no prospective, controlled studies examining the role of UDCA for the prevention of gallstones following sleeve gastrectomy (SG). This study was conducted to identify the effectiveness of UDCA for prevention of gallstones after SG. Following SG, eligible patients were randomized to a control group who did not receive UDCA treatment or to a group who were prescribed 300 mg UDCA twice daily for 6 months. Gallbladder ultrasounds were performed preoperatively and at 6 and 12 months postoperatively. Patients with positive findings preoperatively were excluded from the study. Compliance with UDCA was assessed. Between December 2011 and April 2013, 37 patients were randomized to the UDCA treatment arm and 38 patients were randomized to no treatment. At baseline, the two groups were similar. At 6 months, the UDCA group had a statistically significant lower incidence of gallstones (p = 0.032). Analysis revealed no significant difference in gallstones between the two groups at 1 year (p = 0.553 and p = 0.962, respectively). The overall gallstone formation rate was 29.8%. The incidence of gallstones is higher than previously estimated in SG patients. UDCA significantly lowers the gallstone formation rate at 6 months postoperatively.

  9. UV reactor flow visualization and mixing quantification using three-dimensional laser-induced fluorescence.

    Science.gov (United States)

    Gandhi, Varun; Roberts, Philip J W; Stoesser, Thorsten; Wright, Harold; Kim, Jae-Hong

    2011-07-01

    Three-dimensional laser-induced fluorescence (3DLIF) was applied to visualize and quantitatively analyze mixing in a lab-scale UV reactor consisting of one lamp sleeve placed perpendicular to flow. The recirculation zone and the von Karman vortex shedding that commonly occur in flows around bluff bodies were successfully visualized. Multiple flow paths were analyzed by injecting the dye at various heights with respect to the lamp sleeve. A major difference in these pathways was the amount of dye that traveled close to the sleeve, i.e., a zone of higher residence time and higher UV exposure. Paths away from the center height had higher velocities and hence minimal influence by the presence of sleeve. Approach length was also characterized in order to increase the probability of microbes entering the region around the UV lamp. The 3DLIF technique developed in this study is expected to provide new insight on UV dose delivery useful for the design and optimization of UV reactors. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Evaluation of Nutritional Status Post Laparoscopic Sleeve Gastrectomy-5-Year Outcomes.

    Science.gov (United States)

    Al-Mutawa, Aliaa; Al-Sabah, Salman; Anderson, Alfred Kojo; Al-Mutawa, Mohammad

    2017-12-01

    Obesity is considered a public health problem and has led to advancements in bariatric surgery. Laparoscopic sleeve gastrectomy (LSG) had become the most performed procedure worldwide; however, its consequences on nutritional status in the short and long term are of concern. A retrospective analysis of medical records and bariatric database of patients who underwent LSG from October 2008-September 2015 at Al-Amiri Hospital, Kuwait, was performed. Data regarding nutritional status along with demographic data were collected over a 5-year follow-up period. One thousand seven hundred ninety-three patients comprising of 74% females and 26% males were included. The greatest % total body weight loss (%TBWL) was at 18 months post-LSG (33%), corresponding to a % excess weight loss (%EWL) of 73.8%. With regard to nutritional status, vitamin B1 showed a significant drop at 3-5 years post-op in comparison to pre-op value, but stayed within the normal range throughout the study. Red blood cells count, hemoglobin, and hematocrit also showed a significant drop starting from 6 months post-op until the fifth year of follow-up. On the other hand, vitamins B6 and B12 showed a significant increase at 6 months post-op and decreased afterwards, but did not reach pre-op values. Vitamin D also showed a significant increase throughout the study period from deficient value at the pre-op time, but remained insufficient. Albumin, transferrin, folate, ferritin, iron, and vitamin B2 showed no significant changes at 5 years post-LSG compared to pre-op values. Little is known about the nutritional status and optimal nutritional care plan post-LSG, especially in the longer term. Nutritional deficiencies were prevalent prior and post-LSG. Some of the nutritional parameters improved and even reached the abnormal high level post-LSG. These observations highlight the importance of pre- and post-operative nutritional assessment and tailored supplementation to ensure optimal nutritional status.

  11. Can groundwater sampling techniques used in monitoring wells influence methane concentrations and isotopes?

    Science.gov (United States)

    Rivard, Christine; Bordeleau, Geneviève; Lavoie, Denis; Lefebvre, René; Malet, Xavier

    2018-03-06

    Methane concentrations and isotopic composition in groundwater are the focus of a growing number of studies. However, concerns are often expressed regarding the integrity of samples, as methane is very volatile and may partially exsolve during sample lifting in the well and transfer to sampling containers. While issues concerning bottle-filling techniques have already been documented, this paper documents a comparison of methane concentration and isotopic composition obtained with three devices commonly used to retrieve water samples from dedicated observation wells. This work lies within the framework of a larger project carried out in the Saint-Édouard area (southern Québec, Canada), whose objective was to assess the risk to shallow groundwater quality related to potential shale gas exploitation. The selected sampling devices, which were tested on ten wells during three sampling campaigns, consist of an impeller pump, a bladder pump, and disposable sampling bags (HydraSleeve). The sampling bags were used both before and after pumping, to verify the appropriateness of a no-purge approach, compared to the low-flow approach involving pumping until stabilization of field physicochemical parameters. Results show that methane concentrations obtained with the selected sampling techniques are usually similar and that there is no systematic bias related to a specific technique. Nonetheless, concentrations can sometimes vary quite significantly (up to 3.5 times) for a given well and sampling event. Methane isotopic composition obtained with all sampling techniques is very similar, except in some cases where sampling bags were used before pumping (no-purge approach), in wells where multiple groundwater sources enter the borehole.

  12. Neutron borehole logging correction technique

    International Nuclear Information System (INIS)

    Goldman, L.H.

    1978-01-01

    In accordance with an illustrative embodiment of the present invention, a method and apparatus is disclosed for logging earth formations traversed by a borehole in which an earth formation is irradiated with neutrons and gamma radiation produced thereby in the formation and in the borehole is detected. A sleeve or shield for capturing neutrons from the borehole and producing gamma radiation characteristic of that capture is provided to give an indication of the contribution of borehole capture events to the total detected gamma radiation. It is then possible to correct from those borehole effects the total detected gamma radiation and any earth formation parameters determined therefrom

  13. Vertical sleeve gastrectomy reduces blood pressure and hypothalamic endoplasmic reticulum stress in mice

    Directory of Open Access Journals (Sweden)

    Anne K. McGavigan

    2017-03-01

    Full Text Available Bariatric surgery, such as vertical sleeve gastrectomy (VSG, causes remarkable improvements in cardiometabolic health, including hypertension remission. However, the mechanisms responsible remain undefined and poorly studied. Therefore, we developed and validated the first murine model of VSG that recapitulates the blood pressure-lowering effect of VSG using gold-standard radiotelemetry technology. We used this model to investigate several potential mechanisms, including body mass, brain endoplasmic reticulum (ER stress signaling and brain inflammatory signaling, which are all critical contributors to the pathogenesis of obesity-associated hypertension. Mice fed on a high-fat diet underwent sham or VSG surgery and radiotelemeter implantation. Sham mice were fed ad libitum or were food restricted to match their body mass to VSG-operated mice to determine the role of body mass in the ability of VSG to lower blood pressure. Blood pressure was then measured in freely moving unstressed mice by radiotelemetry. VSG decreased energy intake, body mass and fat mass. Mean arterial blood pressure (MAP was reduced in VSG-operated mice compared with both sham-operated groups. VSG-induced reductions in MAP were accompanied by a body mass-independent decrease in hypothalamic ER stress, hypothalamic inflammation and sympathetic nervous system tone. Assessment of gut microbial populations revealed VSG-induced increases in the relative abundance of Gammaproteobacteria and Enterococcus, and decreases in Adlercreutzia. These results suggest that VSG reduces blood pressure, but this is only partly due to the reduction in body weight. VSG-induced reductions in blood pressure may be driven by a decrease in hypothalamic ER stress and inflammatory signaling, and shifts in gut microbial populations.

  14. Barium swallow for hiatal hernia detection is unnecessary prior to primary sleeve gastrectomy.

    Science.gov (United States)

    Goitein, David; Sakran, Nasser; Rayman, Shlomi; Szold, Amir; Goitein, Orly; Raziel, Asnat

    2017-02-01

    Hiatal hernia (HH) is common in the bariatric population. Its presence imposes various degrees of difficulty in performing laparoscopic sleeve gastrectomy (LSG). Preoperative upper gastrointestinal evaluation consists of fluoroscopic and or endoscopic studies OBJECTIVES: To evaluate the efficacy of routine, preoperative barium swallow in identifying HH in patients undergoing LSG, and determine if such foreknowledge changes operative and immediate postoperative course regarding operative time, intraoperative adverse events, and length of hospital stay (LOS). In addition, to quantify HH prevalence in these patients and correlate preoperative patient characteristics with its presence. High-volume bariatric practice in a private hospital in Israel METHODS: Retrospective analysis of prospectively collected data between October 2010 and March 2015: anthropometrics, co-morbidities, previous barium swallow, preoperative HH workup (type and result), operative and immediate postoperative course. Primary LSG was performed in 2417 patients. The overall prevalence of HH was 7.3%. Preoperative diagnosis of gastroesophageal reflux disease and female gender were independent risk factors for HH presence. Operative times were significantly longer when HH was concomitantly repaired but "foreknowledge" thereof did not assist in shortening this time. Looking for an HH that was suggested in preoperative upper gastrointestinal evaluation slightly prolonged surgery. LOS was not changed in a significant fashion by HH presence and repair, whether suspected or incidentally found. Routine, pre-LSG barium swallow does not seem to offer an advantage over selective intraoperative hiatal exploration, in the discovery and management of HH. Conversely, when preoperative workup yields a false-positive result, surgery is slightly prolonged. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  15. Metabolic, behavioral, and reproductive effects of vertical sleeve gastrectomy in an obese rat model of polycystic ovary syndrome.

    Science.gov (United States)

    Ressler, Ilana B; Grayson, Bernadette E; Seeley, Randy J

    2014-06-01

    Polycystic ovary syndrome (PCOS) is the most common endocrinopathy affecting women of reproductive age. Its clinical expression is diverse, including metabolic, behavioral, and reproductive effects, with many affected by obesity and decreased quality of life. Women with PCOS who have undergone surgically induced weight loss have reported tremendous benefit, not only with weight loss, but also improvement of hyperandrogenism and menstrual cyclicity. In a rat model of PCOS achieved via chronic administration of dihydrotestosterone (DHT) exposure, we investigated the ability of bariatric surgery, specifically vertical sleeve gastrectomy (VSG), to ameliorate the metabolic, behavioral, and reproductive abnormalities invoked by this PCOS model. We found that DHT treatment combined with exposure to a high-fat diet resulted in increased body weight and body fat, impaired fasting glucose, hirsutism, anxiety, and irregular cycles. VSG resulted in reduced food intake, body weight, and adiposity with improved fasting glucose and triglycerides. VSG induced lower basal corticosterone levels and attenuated stress responsivity. Once the DHT levels decreased to normal, regular estrous cyclicity was also restored. VSG, therefore, improved PCOS manifestations in a comprehensive manner and may represent a potential therapeutic approach for specific aspects of PCOS.

  16. Role of ursodeoxycholic acid in the prevention of gallstone formation after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Abdallah, Emad; Emile, Sameh Hany; Elfeki, Hossam; Fikry, Mohamed; Abdelshafy, Mahmoud; Elshobaky, Ayman; Elgendy, Hesham; Thabet, Waleed; Youssef, Mohamed; Elghadban, Hosam; Lotfy, Ahmed

    2017-07-01

    Postoperative cholelithiasis (CL) is a latent complication of bariatric surgery. The aim of this study was to evaluate the role of ursodeoxycholic acid (UDCA) in the prevention of CL after laparoscopic sleeve gastrectomy (LSG). This was a retrospective analysis of the prospectively collected data of patients with morbid obesity who underwent LSG. Patients were subdivided into two groups: Group I, which did not receive prophylactic treatment with UCDA after LSG; and Group II, which received UCDA therapy for 6 months after LSG. Patients' characteristics, operation duration, weight loss data, and incidence of CL at 6 and 12 months postoperatively were collected. A total of 406 patients (124 males, 282 females) with a mean age of 32.1 ± 9.4 years were included. The mean baseline body mass index (BMI) was 50.1 ± 8.3 kg/m 2 . Group I comprised 159 patients, and Group II comprised 247 patients. The two groups showed comparable demographics, % excess weight loss (EWL), and decrease in BMI at 6 and 12 months after LSG. Eight patients (5%) developed CL in Group I, whereas no patients in Group II did (P = 0.0005). Preoperative dyslipidemia and rapid loss of excess weight within the first 3 months after LSG were the risk factors that significantly predicted CL postoperatively. The use of UCDA effectively reduced the incidence of CL after LSG in patients with morbid obesity. Dyslipidemia and rapid EWL in the first 3 months after LSG significantly predisposed patients to postoperative CL.

  17. Florida Sleeve Procedure Is Durable and Improves Aortic Valve Function in Marfan Syndrome Patients.

    Science.gov (United States)

    Aalaei-Andabili, Seyed Hossein; Martin, Tomas; Hess, Philip; Klodell, Charles; Karimi, Ashkan; Arnaoutakis, George; Lee, Teng; Beaver, Thomas

    2017-09-01

    The Florida sleeve (FS) procedure was developed as a simplified approach for repair of functional type I aortic insufficiency secondary to aortic root aneurysm. We evaluated postoperative aortic valve function, long-term survival, and freedom from reoperation in Marfan syndrome patients who underwent the FS procedure at our center. All Marfan syndrome patients undergoing FS procedure from May 2002 to December 2014 were included. Echocardiography assessment included left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD), ejection fraction, and degree of aortic insufficiency (none = 0, minimal = 1, mild = 2, moderate = 3, severe = 4). Social Security Death Index and primary care physicians' report were used for long-term follow-up. Thirty-seven Marfan syndrome patients, 21 (56.8%) men and 16 (43%) women with mean age of 35.08 ± 13.45 years underwent FL repair at our center. There was no in-hospital or 30-day death or stroke. Two patients required reoperation due to bleeding. Patients' survival rate was 94% at 1 to 8 years. Freedom from reoperation was 100% at 8 years. Twenty-five patients had postoperative follow-up echocardiography at 1 week. Aortic insufficiency grade significantly decreased after the procedure (preoperative mean ± SD: 1.76 ± 1.2 versus 1-week postoperative mean ± SD: 0.48 ± 0.71, p Marfan syndrome patients with immediate improvement in aortic valve function. Long-term survival and freedom from reoperation rates are encouraging. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Age is not associated with increased surgical complications in patients after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Jędrzejewski, Emil; Liszka, Maciej; Maciejewski, Marcin; Kowalewski, Piotr K; Walędziak, Maciej; Paśnik, Krzysztof; Janik, Michał R

    2018-03-01

    Age is considered as a risk factor in bariatric surgery. The observation was made on the basis of results from studies where patients underwent different type of surgery, but laparoscopic sleeve gastrectomy (LSG) was not among them. It is necessary to reevaluate the association of age with adverse events in the group of patients after LSG. To investigate the association of age with surgery-related adverse events in patients after LSG. Retrospective analysis of medical data was performed. The study involved 345 patients who underwent LSG in our institution between January 2013 and December 2014. The patients were subdivided by age into four groups according to quartiles. In 30-day follow-up adverse events were evaluated. We considered the presence of the following events as the endpoint of our study: death, medical events and surgical events. In general, we observed adverse events in 36 (10.4%) patients. The mortality rate in our study was 0.59%. Nineteen events were surgical and 18 medical. In 1 patient a surgical event was associated with a medical event. Bleeding was the most common surgical event and was observed in 17 (4.9%) cases. Age was not associated with surgical events (OR = 1.032, 95% CI: 0.991-1.075, p = 0.33) or medical events (OR = 0.997, 95% CI: 0.956-1.039, p = 0.89). The LSG is a safe bariatric procedure with low mortality. Bleeding is the most frequent surgical complication. Our findings suggest that age is not associated with increased risk of surgical or medical adverse events after LSG.

  19. Thermal analysis of a hybrid solar energy saving system inside a greenhouse

    International Nuclear Information System (INIS)

    Ntinas, G.K.; Fragos, V.P.; Nikita-Martzopoulou, Ch.

    2014-01-01

    Highlights: • A hybrid solar system consisted of water filled polyethylene sleeves was examined. • The thermal behaviour of the system was studied based on the sleeves energy balance. • Water temperature and heat exchanges of the sleeves were dynamically estimated. • Experimental data used to validate the predictions of the mathematical model. • The use of the system led to an energy saving of 23% inside a heated greenhouse. - Abstract: The intensive greenhouse energy requirements are a major operational and economical problem for producers around the world. Energy conservation techniques and innovative applications of solar energy for heating are being employed in greenhouse operation to reduce heating costs during cold periods. The present study investigated the development of a mathematical model to predict the thermal efficiency of a novel hybrid solar energy saving system inside a heated greenhouse. The solar system consisted of a transparent water-filled polyethylene sleeve and two perforated air-filled polyethylene tubes on the top peripheral sides of it. Above the sleeve and between the two tubes, rockwool substrates were placed for hydroponic cultivation of tomato crop. In order to validate this model, experiments were carried out in two identical parts of a polyethylene arched-type greenhouse to obtain data during winter. By comparing the measured and the predicted values, a correlation of 95% was found, indicating that the model can simulate the water temperature inside the hybrid solar sleeves. Moreover, the additional energy provided by the hybrid solar system reached approximately 23% during the examined period, depending on solar radiation levels

  20. An Update on Less Invasive and Endoscopic Techniques Mimicking the Effect of Bariatric Surgery

    Directory of Open Access Journals (Sweden)

    Froukje J. Verdam

    2012-01-01

    Full Text Available Obesity (BMI 30–35 kg/m2 and its associated disorders such as type 2 diabetes, nonalcoholic fatty liver disease, and cardiovascular disease have reached pandemic proportions worldwide. For the morbidly obese population (BMI 35–50 kg/m2, bariatric surgery has proven to be the most effective treatment to achieve significant and sustained weight loss, with concomitant positive effects on the metabolic syndrome. However, only a minor percentage of eligible candidates are treated by means of bariatric surgery. In addition, the expanding obesity epidemic consists mostly of relatively less obese patients who are not (yet eligible for bariatric surgery. Hence, less invasive techniques and devices are rapidly being developed. These novel entities mimic several aspects of bariatric surgery either by gastric restriction (gastric balloons, gastric plication, by influencing gastric function (gastric botulinum injections, gastric pacing, and vagal nerve stimulation, or by partial exclusion of the small intestine (duodenal-jejunal sleeve. In the last decade, several novel less invasive techniques have been introduced and some have been abandoned again. The aim of this paper is to discuss the safety, efficacy, complications, reversibility, and long-term results of these latest developments in the treatment of obesity.

  1. Is type 2 diabetes really resolved after laparoscopic sleeve gastrectomy? Glucose variability studied by continuous glucose monitoring.

    Science.gov (United States)

    Capoccia, D; Coccia, F; Guida, A; Rizzello, M; De Angelis, F; Silecchia, G; Leonetti, F

    2015-01-01

    The study was carried out on type 2 diabetic obese patients who underwent laparoscopic sleeve gastrectomy (LSG). Patients underwent regular glycemic controls throughout 3 years and all patients were defined cured from diabetes according to conventional criteria defined as normalization of fasting glucose levels and glycated hemoglobin in absence of antidiabetic therapy. After 3 years of follow-up, Continuous Glucose Monitoring (CGM) was performed in each patient to better clarify the remission of diabetes. In this study, we found that the diabetes resolution after LSG occurred in 40% of patients; in the other 60%, even if they showed a normal fasting glycemia and A1c, patients spent a lot of time in hyperglycemia. During the oral glucose tolerance test (OGTT), we found that 2 h postload glucose determinations revealed overt diabetes only in a small group of patients and might be insufficient to exclude the diagnosis of diabetes in the other patients who spent a lot of time in hyperglycemia, even if they showed a normal glycemia (<140 mg/dL) at 120 minutes OGTT. These interesting data could help clinicians to better individualize patients in which diabetes is not resolved and who could need more attention in order to prevent chronic complications of diabetes.

  2. Formal Nutritional Education Improves Weight Loss in Bariatric Patients Following Laparoscopic Sleeve Gastrectomy.

    Science.gov (United States)

    Mangieri, Christopher Wesley; Strode, Matthew A

    2016-12-01

    Laparoscopic sleeve gastrectomy (LSG) is an increasingly performed procedure in the bariatric surgery armamentarium. This study evaluates our experience with LSG at Dwight D. Eisenhower Army Medical Center (DDEAMC) during the time period of 2008-2010. We found that the inclusion of formal nutritional education significantly increased our weight loss results following LSG. This is a retrospective review from our LSG caseload from 2008 to 2010. During that time, we performed 159 LSG. In our review, we performed comparative data of all operative years during 2008-2010 for up to 3 years postoperatively. Our main focus was in regard to weight loss as measured by percentage of excess body weight loss (%EWL), percentage of total weight loss (%TWL), and percentage of excess BMI loss (%EBL). We also evaluated the effect of LSG on diabetes mellitus (DM) and hypertension (HTN) postoperatively. We found an improvement in our %EWL, %TWL, and %EBL rates in our LSG cases following the inclusion of formal nutritional education. There was a mean increase in %EWL of 15 %, %TWL of 7 %, and %EBL of 21 %, which were statistically significant, that was present at all postoperative years of follow-up. We determined the only variable that changed in our bariatric program starting in 2010 was the inclusion of formal nutritional education. We also found a statistically significant improvement in resolution of HTN with the inclusion of formal nutritional education. The addition of formal nutritional education can enhance weight loss following bariatric surgery. We have shown a significant improvement in weight loss results following LSG with the implementation of formal nutritional education; this is the only study to our knowledge evaluating formal nutritional education and LSG.

  3. Pharmacokinetics in Morbid Obesity: Influence of Two Bariatric Surgery Techniques on Paracetamol and Caffeine Metabolism.

    Science.gov (United States)

    Goday Arno, Albert; Farré, Magí; Rodríguez-Morató, Jose; Ramon, Jose M; Pérez-Mañá, Clara; Papaseit, Esther; Civit, Ester; Langohr, Klaus; Lí Carbó, Marcel; Boix, David Benaiges; Nino, Olga Castañer; Le Roux, Juana Antonia Flores; Pera, Manuel; Grande, Luis; de la Torre, Rafael

    2017-12-01

    The purpose of the study was to study the impact of the two most common bariatric surgery techniques on paracetamol pharmacokinetics (a marker of gastric emptying) and caffeine metabolism (a marker of liver function). In the present prospective study, we studied 24 morbid obese patients before, at 4 weeks, and 6 months after having undergone sleeve gastrectomy (n = 10) or Roux-en-Y gastric bypass (n = 14). For comparative purposes, 28 healthy controls (14 normal weights and 14 overweights) were also included in the study. Paracetamol pharmacokinetics was altered in the obese participants leading to lower bioavailability. Bariatric surgery resulted in faster absorption and normalized pharmacokinetic parameters, prompting an increase in paracetamol bioavailability. No differences were found between surgical procedures. In the case of caffeine, the ratio paraxanthine/caffeine did not differ between morbid obese and healthy individuals. This ratio remained unmodified after surgery, indicating that the liver function (assessed by cytochrome P450 1A2 activity) was unaffected by obesity or bariatric surgery. Paracetamol pharmacokinetics and caffeine plasma levels are altered in severely obese patients. The two studied bariatric surgical techniques normalize paracetamol oral bioavailability without impairing the liver function (measured by cytochrome P450 1A2 activity).

  4. 75 FR 60508 - Proposed Collection: Comment Request for Regulation Project

    Science.gov (United States)

    2010-09-30

    ... ``direct rollover'' transaction. These provisions also require qualified pension plans and tax-sheltered... comments concerning an existing final regulation, EE-43-92 (TD 8619), Direct Rollovers and 20- Percent... November 29, 2010 to be assured of consideration. ADDRESSES: Direct all written comments to Gerald Shields...

  5. Magnet-Sleeve-Sealed Mini Trochoidal-Gear Pump Prototype with Polymer Composite Gear

    Directory of Open Access Journals (Sweden)

    Pedro Javier Gamez-Montero

    2017-09-01

    Full Text Available The trochoidal-gear technology has been growing in groundbreaking fields. Forthcoming applications are demanding to this technology a step forward in the conceiving stage of positive displacement machines. The compendium of the qualities and the inherent characteristics of trochoidal-gear technology, especially towards the gerotor pump, together with scale/size factor and magnetic-driven transmission has led to the idea of a magnet-sleeve-sealed variable flow mini trochoidal-gear pump. From its original concept, to the last phase of the design development, the proof of concept, this new product will intend to overcome problems such as noise, vibration, maintenance, materials, and dimensions. The paper aims to show the technological path followed from the concept, design, and model, to the manufacture of the first prototype, where the theoretical and numerical approaches are not always directly reflected in the prototype performance results. Early in the design process, from a standard-commercial sintered metal mini trochoidal-gear unit, fundamental characteristics and dimensional limitations have been evaluated becoming the strategic parameters that led to its configuration. The main technical challenge to confront is being sealed with non-exterior driveshaft, ensuring that the whole interior is filled and wetted with working fluid and helping the hydrodynamic film formation, the pumping effect, and the heat dissipation. Subsequently, the mini pump architecture, embodiment, methodology, materials, and manufacture are presented. The trend of applications of polymer composite materials and their benefits wanted to be examined with this new mini pump prototype, and a pure polyoxymethylene mini trochoidal-gear set has been designed and manufactured. Finally, both the sintered and the polymer trochoidal-gear units have been experimentally tested in an in-house full-instrumented mini test bench. Although the main goal of the presented work is the

  6. Gastroesophageal Reflux Disease After Laparoscopic Sleeve Gastrectomy with Concomitant Hiatal Hernia Repair: an Unresolved Question.

    Science.gov (United States)

    Dakour Aridi, Hanaa; Asali, Mohammad; Fouani, Tarek; Alami, Ramzi S; Safadi, Bassem Y

    2017-11-01

    The effectiveness of the concomitant repair of hiatal hernia (HHR) during laparoscopic sleeve gastrectomy (LSG) in reducing gastroesophageal reflux disease (GERD) symptoms is still unclear. The aim of this study is to assess the effect of concomitant HHR on postoperative GERD symptoms in our patient population. A retrospective review of patients who underwent LSG with or without HHR between 2011and 2014 was performed. Pre- and postoperative GERD symptoms were assessed at different time intervals until a maximum of 2 years after the surgery. The study included 165 patients; 76 (46%) underwent LSG with concomitant HHR (group A) while the rest underwent only LSG (group B). Baseline GERD complaints were more prevalent in group A (61.8 vs 41.6%, p = 0.04), in which 44 patients (57.9%) had evidence of hiatal hernia on preoperative EGD. In the remaining 32 patients, it was diagnosed intraoperatively. GERD symptoms did not significantly differ between the two groups after years 1 and 2. GERD remission was observed in 21.3% of the 76 patients who underwent concomitant HHR (group A) and in 29.7% of those who did not (group B) while new-onset GERD symptoms were reported in 12 patients (41.4%) in group A and in 24 patients (46.2%) in group B. Routine HHR at the time of LSG does not show an improvement in GERD symptoms. More prospective studies are needed to clarify the role of the routine dissection, identification, and repair of concomitant hiatal hernia during LSG.

  7. Long-Term Results of Laparoscopic Sleeve Gastrectomy for Morbid Obesity: 5 to 8-Year Results.

    Science.gov (United States)

    Gadiot, Ralph P M; Biter, L Ulas; van Mil, Stefanie; Zengerink, Hans F; Apers, J; Mannaerts, Guido H H

    2017-01-01

    Although long-term results of sleeve gastrectomy (LSG) remain scarce in the literature, its popularity as a stand-alone procedure has accounted for a global increase in LSG performance. In this retrospective study, the authors present 5 to 8-year follow-up results in terms of weight loss, failure/revision rate, and comorbidity resolution from a single center. A prospectively maintained database was reviewed for patients who underwent LSG between 2007 and 2010. Data analysis on weight loss, comorbid conditions, revision surgery, and mortality was conducted. Median percentage excess BMI loss (%EBMIL) was 59.0, and 53.9 %, and median percentage total weight loss (%TWL) was 25.1, and 22.9 % at 5 and 8 years, respectively. Revision to gastric bypass due to insufficient weight loss or gastroesophageal reflux disease (GERD) was performed in 42 patients (15.2 %). Resolution of comorbid condition was achieved in 91 % of patients with obstructive sleep apnea syndrome (OSAS), 68 % of patients with type 2 diabetes (T2DM), 53 % of patients with hypertension, and 25 % of patients with dyslipedemia. Loss to follow-up rate was 45 % at 5 years, 28 % at 6 years, 23 % at 7 years, and 13 % at 8 years. This study adds to the currently available data confirming the LSG to be a safe and effective procedure at long term. Data from high-volume studies are needed to establish the definite role of the LSG in the spectrum of bariatric procedures.

  8. Long constructs in the thoracic and lumbar spine with a minimally invasive technique.

    Science.gov (United States)

    Roldan, H; Perez-Orribo, L; Spreafico, M; Ginoves-Sierra, M

    2011-04-01

    Literature about long implants used together with a minimally invasive spine surgery (MISS) technique is scarce. Our objective is to contribute our surgical experience in this field and to specifically focus on several technical details. A digitally-dissected canal along the paravertebral muscles was created linking the stab wounds on each side in relation with the pedicles to be cannulated. Screws were inserted following the percutaneous technique. Long rods were modelled, threaded through the extender sleeves along the paravertebral canal and pushed into the screw heads with the reduction forceps. When fusion was needed, the facet complex was decorticated with a drill. To insert a cross-link, a canal between the 2 rods was digitally created and the spinous process was drilled. 8 patients underwent surgery (age range: 25-77 years). Indications were postosteomyelitis kyphosis in 3 patients, bone tumor in 3, and spine fracture in 2. No blood transfusions were necessary during or after surgery. A cross-link was inserted in 2 patients. Posterolateral bone fusion was attempted in 4, but radiologically identifiable in none. In one patient a cantilever manoeuvre was done to correct kyphosis. Mean duration of surgery was 4 h. There were no clinical complications related to the operation or the hardware (mean follow-up of 7.14 months, range: 1-15 months). The application of MISS techniques can be broadened to long spinal constructs to assess fractures, tumors or deformity, especially in elderly or debilitated patients. Nevertheless, posterolateral fusion is still a challenge through these limited exposures. © Georg Thieme Verlag KG Stuttgart · New York.

  9. The role of proximal versus distal stomach resection in the weight loss seen after vertical sleeve gastrectomy

    Science.gov (United States)

    Kulkarni, Bhushan V.; LaSance, Kathleen; Sorrell, Joyce E.; Lemen, Lisa; Woods, Stephen C.; Seeley, Randy J.

    2016-01-01

    The mechanisms involved in the weight loss seen after vertical sleeve gastrectomy (VSG) are not clear. The rat stomach has two morphologically and functionally distinct proximal and distal parts. The rat model for VSG involves complete removal of the proximal part and 80% removal of the distal part along the greater curvature. The purpose of this study was to understand the potential independent contributions of removal of these distinct gastric sections to VSG outcomes. We prepared four surgical groups of male Long-Evans rats: VSG, sham surgery (control), selective proximal section removal (PR), and selective distal section removal (DR). Gastric emptying rate (GER) was highest after VSG compared with all other groups. However, PR, in turn, had significantly greater GER compared with both DR and sham groups. The surgery-induced weight loss followed the same pattern with VSG causing the greatest weight loss and PR having greater weight loss compared with DR and sham groups. The results were robust for rats fed regular chow or a high-fat diet. Body mass analysis revealed that the weight loss was due to the loss of fat mass, and there was no change in lean mass after the surgeries. In conclusion, removal of the proximal stomach contributes to most, but not all, of the physiological impact of VSG. PMID:27581811

  10. Results of More Than 11,800 Sleeve Gastrectomies: Data Analysis of the German Bariatric Surgery Registry.

    Science.gov (United States)

    Stroh, Christine; Köckerling, Ferdinand; Volker, Lange; Frank, Benedix; Stefanie, Wolff; Christian, Knoll; Christiane, Bruns; Thomas, Manger

    2016-05-01

    Laparoscopic sleeve gastrectomy (SG) is an upcoming procedure in bariatric surgery and is currently performed worldwide. Staple line leakage, as the most frequent and most feared complication, is still a major concern. Since 2005 data from patients undergoing bariatric procedures in Germany have been prospectively registered in an online database and analyzed. All patients who had undergone primary SG within a 7-year period were considered for analysis. Using the German Bariatric Surgery Registry, data from more than 11,800 SGs were collected between January 1, 2005, and December 31, 2013. Staple line leak rate decreased from 6.5% to 1.4%. Male sex, higher body mass index, concomitant sleep apnea, conversion to laparotomy, longer operation time, a combination of buttresses and oversewing, and the occurrence of intraoperative complications were associated with a significantly higher leakage rate compared with when using either buttresses or oversewing alone. On multivariable analysis, operation time and year of procedure only had a significant impact on staple line leakage rate. Owing to the growing experience a constant decrease in the leakage rate after SG has been observed. Staple line disruption may still lead to sepsis, multiorgan dysfunction, and increased mortality. The results of the current study demonstrated that there are factors that increase the risk of leakage and which would enable surgeons to define risk groups, select patients more carefully, and offer closer follow-up during the postoperative course with early recognition and adequate treatment.

  11. Evaluation of insulin resistance improvement after laparoscopic sleeve gastrectomy or gastric bypass surgery with HOMA-IR.

    Science.gov (United States)

    Zhu, Yubing; Sun, Zhipeng; Du, Yanmin; Xu, Guangzhong; Gong, Ke; Zhu, Bin; Zhang, Nengwei

    2017-01-01

    Our purpose was to explore the remission of insulin resistance after bariatric surgery to discover the mechanism of diabetes remission excluding dietary factors. A retrospective case control study was conducted on patients with type 2 diabetes, who underwent laparoscopic sleeve gastrectomy (LSG) or laparoscopic gastric bypass surgery (LGB) in Beijing Shijitan Hospital from April 1, 2012 to April 1, 2013. The laboratory and anthropometric data was analyzed pre-surgery and during a 2-year follow-up. HOMA-IR was calculated and evaluated. The two surgical procedures were compared. No significant difference in complete remission rate was observed between the two groups (LGB group: 62.1%, LSG group: 60.0%, p = 0.892). HOMA-IR was reduced to a stable level at the 3 rd month after surgery. The cut-off value of HOMA-IR was 2.38 (sensitivity: 0.938, specificity: 0.75) and 2.33 (sensitivity: 0.941, specificity: 0.778) respectively for complete remission after LSG or LGB surgery. Insulin resistance was improved while GLP-1 and Ghrelin was changed significantly in patients with type 2 diabetes prior to weight loss either in the LSG or LGB group. HOMA-IR decreased to less than the cut-off value at the 3 rd month and was closely related to complete remission. The mechanism of bariatric surgery was not due just to simply dietary factors or body weight loss but also the remission of insulin resistance.

  12. Using Arm and Hand Gestures to Command Robots during Stealth Operations

    Science.gov (United States)

    Stoica, Adrian; Assad, Chris; Wolf, Michael; You, Ki Sung; Pavone, Marco; Huntsberger, Terry; Iwashita, Yumi

    2012-01-01

    Command of support robots by the warfighter requires intuitive interfaces to quickly communicate high degree-of-freedom (DOF) information while leaving the hands unencumbered. Stealth operations rule out voice commands and vision-based gesture interpretation techniques, as they often entail silent operations at night or in other low visibility conditions. Targeted at using bio-signal inputs to set navigation and manipulation goals for the robot (say, simply by pointing), we developed a system based on an electromyography (EMG) "BioSleeve", a high density sensor array for robust, practical signal collection from forearm muscles. The EMG sensor array data is fused with inertial measurement unit (IMU) data. This paper describes the BioSleeve system and presents initial results of decoding robot commands from the EMG and IMU data using a BioSleeve prototype with up to sixteen bipolar surface EMG sensors. The BioSleeve is demonstrated on the recognition of static hand positions (e.g. palm facing front, fingers upwards) and on dynamic gestures (e.g. hand wave). In preliminary experiments, over 90% correct recognition was achieved on five static and nine dynamic gestures. We use the BioSleeve to control a team of five LANdroid robots in individual and group/squad behaviors. We define a gesture composition mechanism that allows the specification of complex robot behaviors with only a small vocabulary of gestures/commands, and we illustrate it with a set of complex orders.

  13. Novel high dose rate lip brachytherapy technique to improve dose homogeneity and reduce toxicity by customized mold

    International Nuclear Information System (INIS)

    Feldman, Jon; Appelbaum, Limor; Sela, Mordechay; Voskoboinik, Ninel; Kadouri, Sarit; Weinberger, Jeffrey; Orion, Itzhak; Meirovitz, Amichay

    2014-01-01

    The purpose of this study is to describe a novel brachytherapy technique for lip Squamous Cell Carcinoma, utilizing a customized mold with embedded brachytherapy sleeves, which separates the lip from the mandible, and improves dose homogeneity. Seven patients with T2 lip cancer treated with a “sandwich” technique of High Dose Rate (HDR) brachytherapy to the lip, consisting of interstitial catheters and a customized mold with embedded catheters, were reviewed for dosimetry and outcome using 3D planning. Dosimetric comparison was made between the “sandwich” technique to “classic” – interstitial catheters only plan. We compared dose volume histograms for Clinical Tumor Volume (CTV), normal tissue “hot spots” and mandible dose. We are reporting according to the ICRU 58 and calculated the Conformal Index (COIN) to show the advantage of our technique. The seven patients (ages 36–81 years, male) had median follow-up of 47 months. Four patients received Brachytherapy and External Beam Radiation Therapy, 3 patients received brachytherapy alone. All achieved local control, with excellent esthetic and functional results. All patients are disease free. The Customized Mold Sandwich technique (CMS) reduced the high dose region receiving 150% (V150) by an average of 20% (range 1–47%), The low dose region (les then 90% of the prescribed dose) improved by 73% in average by using the CMS technique. The COIN value for the CMS was in average 0.92 as opposed to 0.88 for the interstitial catheter only. All differences (excluding the low dose region) were statistically significant. The CMS technique significantly reduces the high dose volume and increases treatment homogeneity. This may reduce the potential toxicity to the lip and adjacent mandible, and results in excellent tumor control, cosmetic and functionality

  14. Numerical analysis of high-power broad-area laser diode with improved heat sinking structure using epitaxial liftoff technique

    Science.gov (United States)

    Kim, Younghyun; Sung, Yunsu; Yang, Jung-Tack; Choi, Woo-Young

    2018-02-01

    The characteristics of high-power broad-area laser diodes with the improved heat sinking structure are numerically analyzed by a technology computer-aided design based self-consistent electro-thermal-optical simulation. The high-power laser diodes consist of a separate confinement heterostructure of a compressively strained InGaAsP quantum well and GaInP optical cavity layers, and a 100-μm-wide rib and a 2000-μm long cavity. In order to overcome the performance deteriorations of high-power laser diodes caused by self-heating such as thermal rollover and thermal blooming, we propose the high-power broad-area laser diode with improved heat-sinking structure, which another effective heat-sinking path toward the substrate side is added by removing a bulk substrate. It is possible to obtain by removing a 400-μm-thick GaAs substrate with an AlAs sacrificial layer utilizing well-known epitaxial liftoff techniques. In this study, we present the performance improvement of the high-power laser diode with the heat-sinking structure by suppressing thermal effects. It is found that the lateral far-field angle as well as quantum well temperature is expected to be improved by the proposed heat-sinking structure which is required for high beam quality and optical output power, respectively.

  15. Portal vein thrombosis after laparoscopic sleeve gastrectomy: presentation and management.

    Science.gov (United States)

    Belnap, LeGrand; Rodgers, George M; Cottam, Daniel; Zaveri, Hinali; Drury, Cara; Surve, Amit

    2016-12-01

    Portal vein thrombosis (PVT) is a serious problem with a high morbidity and mortality, often exceeding 40% of affected patients. Recently, PVT has been reported in patients after laparoscopic sleeve gastrectomy (LSG). The frequency is surprisingly high compared with other abdominal operations. We present a series of 5 patients with PVT after LSG. The treatment was not restricted simply to anticoagulation alone, but was determined by the extent of disease. A distinction is made among nonocclusive, high-grade nonocclusive, and occlusive PVT. We present evidence that systemic anticoagulation is insufficient in occlusive thrombosis and may also be insufficient in high-grade nonocclusive disease. Single private institution, United States. We present a retrospective analysis of 646 patients who underwent LSG between 2012 and 2015. In all patients, the diagnosis was established with an abdominal computed tomography (CT) scan as well as duplex ultrasound of the portal venous system. All patients received systemic anticoagulation. Depending on the extent of disease, thrombolytic therapy and portal vein thrombectomy were utilized. All patients received long-term anticoagulation. Four patients with PVT were identified. A fifth patient with PVT after LSG was referred from another center. The mean age of all patients was 49 years. One patient had a history of deep vein thrombosis (DVT). No complications were identified intraoperatively or during the hospital stay, and all patients were discharged by postoperative day 2. The patients presented with PVT at an average of 20 days (range: 10-35) post-LSG. The CT scan was positive for PVT in all patients. In stable noncirrhotic patients with nonocclusive disease, we administered therapeutic anticoagulation. One patient with high-grade, nonocclusive PVT received anticoagulation alone. Patients with occlusive disease were treated with operative thrombectomy including intraoperative and postoperative thrombolysis (tissue plasminogen

  16. 49 CFR 579.21 - Reporting requirements for manufacturers of 5,000 or more light vehicles annually.

    Science.gov (United States)

    2010-10-01

    ... structure, 17 latch, 18 vehicle speed control, 19 tires, 20 wheels, 22 seats, 23 fire, 24 rollover, 98 where... the incident involved a fire or rollover, coded as follows: 01 steering system, 02 suspension system, 03 service brake system, 05 parking brake, 06 engine and engine cooling system, 07 fuel system, 10...

  17. 77 FR 6504 - Roth Feature to the Thrift Savings Plan and Miscellaneous Uniformed Services Account Amendments

    Science.gov (United States)

    2012-02-08

    ... are, by definition, tax-deferred contributions unless they are Roth contributions. See 26 CFR 1.402(g... traditional IRA, a check indicating that the contribution is a direct rollover, or a tax notice from the plan... the contribution is a direct rollover, or a tax notice from the plan to the participant indicating...

  18. Impact of concomitant laparoscopic sleeve gastrectomy and hiatal hernia repair on gastro-oesophageal reflux disease in morbidly obese patients.

    Science.gov (United States)

    Garg, Harshit; Vigneshwaran, Balasubiramaniyan; Aggarwal, Sandeep; Ahuja, Vineet

    2017-01-01

    The aim of this study was to analyse the impact of hiatal hernia repair (HHR) on gastro-oesophageal reflux disease (GERD) in morbidly obese patients with hiatus hernia undergoing laparoscopic sleeve gastrectomy (LSG). It is a retrospective study involving ten morbidly obese patients with large hiatus hernia diagnosed on pre-operative endoscopy who underwent LSG and simultaneous HHR. The patients were assessed for symptoms of GERD using a Severity symptom score (SS) questionnaire and anti-reflux medications. Of the ten patients, five patients had GERD preoperatively. At the mean follow-up of 11.70 ± 6.07 months after surgery, four patients (80%) showed complete resolution while one patient complained of persistence of symptoms. Endoscopy in this patient revealed resolution of esophagitis indicating that the persistent symptoms were not attributable to reflux. The other five patients without GERD remained free of any symptom attributable to GERD. Thus, in all ten patients, repair of hiatal hernia (HH) during LSG led to either resolution of GERD or prevented any new onset symptom related to GER. In morbidly obese patients with HH with or without GERD undergoing LSG, repair of the hiatus hernia helps in amelioration of GERD and prevents any new onset GER. Thus, the presence of HH should not be considered as a contraindication for LSG.

  19. Routine intraoperative leak testing for sleeve gastrectomy: is the leak test full of hot air?

    Science.gov (United States)

    Bingham, Jason; Lallemand, Michael; Barron, Morgan; Kuckelman, John; Carter, Preston; Blair, Kelly; Martin, Matthew

    2016-05-01

    Staple line leak after sleeve gastrectomy (SG) is a rare but dreaded complication with a reported incidence of 0% to 8%. Many surgeons routinely test the staple line with an intraoperative leak test (IOLT), but there is little evidence to validate this practice. In fact, there is a theoretical concern that the leak test may weaken the staple line and increase the risk of a postop leak. Retrospective review of all SGs performed over a 7-year period was conducted. Cases were grouped by whether an IOLT was performed, and compared for the incidence of postop staple line leaks. The ability of the IOLT for identifying a staple line defect and for predicting a postoperative leak was analyzed. Five hundred forty-two SGs were performed between 2007 and 2014. Thirteen patients (2.4%) developed a postop staple line leak. The majority of patients (n = 494, 91%) received an IOLT, including all 13 patients (100%) who developed a subsequent clinical leak. There were no (0%) positive IOLTs and no additional interventions were performed based on the IOLT. The IOLT sensitivity and positive predictive value were both 0%. There was a trend, although not significant, to increase leak rates when a routine IOLT was performed vs no routine IOLT (2.6% vs 0%, P = .6). The performance of routine IOLT after SG provided no actionable information, and was negative in all patients who developed a postoperative leak. The routine use of an IOLT did not reduce the incidence of postop leak, and in fact was associated with a higher leak rate after SG. Published by Elsevier Inc.

  20. National survey for bariatric procedures in adolescents: Long time follow-up.

    Science.gov (United States)

    Castellani, Roberto Luca; Toppino, Mauro; Favretti, Franco; Camoglio, Francesco Saverio; Zampieri, Nicola

    2017-10-01

    The role of bariatric surgery and its role in adolescent is still under discussion worldwide. The aim of this study is to report an Italian survey for bariatric procedures in adolescents and the outcome with a medium and long-term follow-up. We retrospectively analyzed consecutive data added into the Italian register of the society for bariatric surgery(period 2000-2010). We evaluated all patients treated in a 10-year period with a mean follow-up of 3 years. Inclusion and exclusion criteria were created. All patients were aged between 13 and 18 years. We evaluated and compared clinical data. After reviewing medical charts, 173 patients were considered for the study; 85 patients were treated with adjustable gastric band (AGB), 47 with intragastric balloon (IB), 26 with sleeve gastrectomy (SG) and other 15 patients with malabsorptive techniques (MT). Among clinical data, there was a statistical difference in terms of %excess weight loss (%EWL) between techniques only after 1 year post-procedure; at 5 years, considering the percentage of patients studied, sleeve gastrectomy had the best %EWL respect to other non malabsorptive techniques (padolescent; more than 80% of patients are followed until 5 years post-op but only few patients (less than 5%) until 10 years. Our results demonstrated that sleeve gastrectomy in adolescent is safe and had a better %EWL respect to other non-malabsorptive bariatric procedures. level III. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Optical Coherence Tomography Parameters in Morbidly Obese Patients Who Underwent Laparoscopic Sleeve Gastrectomy

    Directory of Open Access Journals (Sweden)

    Berna Dogan

    2016-01-01

    Full Text Available Purpose. To investigate changes in optical coherence tomography parameters in morbidly obese patients who had undergone laparoscopic sleeve gastrectomy (LSG. Methods. A total of 41 eyes of 41 morbidly obese patients (BMI ≥ 40 who had undergone LSG were included in study. The topographic optic disc parameters, central macular thickness (CMT, total macular volume (TMV, and retinal ganglion cell layer (RGCL were measured by spectral-domain optical coherence tomography (SD-OCT. Subfoveal choroidal thickness (SFCT was measured by enhanced deep imaging-optical coherence tomography (EDI-OCT. Results. The mean CMT was 237.4±24.5 μm, 239.3±24.1 μm, and 240.4±24.5 μm preoperatively, 3 months postoperatively, and 6 months postoperatively, respectively (p<0.01. The mean TMV was 9.88±0.52 mm3, 9.96±0.56 mm3, and 9.99±0.56 mm3 preoperatively, 3 months postoperatively, and 6 months postoperatively, respectively (p<0.01. The mean RGCL was 81.2±6.5 μm, 82.7±6.6 μm, and 82.9±6.5 μm preoperatively, 3 months postoperatively, and 6 months postoperatively, respectively (p<0.01. The mean SFCT was 309.8±71.8 μm, 331.0±81.4 μm, and 352.7±81.4 μm preoperatively, 3 months postoperatively, and 6 months postoperatively, respectively (p<0.01. No statistically significant differences were found between the preoperative values and 3- and 6-month postoperative values in rim area (p=0.34, disc area (p=0.64, vertical cup/disc ratio (p=0.39, cup volume (p=0.08, or retinal nerve fiber layer (p=0.90. Conclusions. Morbidly obese patients who undergo LSG experience a statistically significant increase in CMT, TMV, SFCT, and RGCL at 3 months and 6 months after surgery.

  2. Weight Loss and Glycemic Control after Sleeve Gastrectomy: Results from a Middle Eastern Center of Excellence.

    Science.gov (United States)

    Al Khalifa, Khalid; Al Ansari, Ahmed; Showaiter, May

    2018-02-01

    Obesity and its associated metabolic disorders are strongly linked to both morbidity and mortality. Sleeve gastrectomy (SG) has been established as an effective means of weight loss for obese patients as well as a treatment for type 2 diabetes mellitus (T2DM). This study was designed to examine the short- and midterm outcomes of patients who underwent SG in a Middle Eastern Center of Excellence, a military training teaching hospital. The clinical outcomes of 59 patients with impaired glucose tolerance and T2DM who underwent SG between 2011 and 2014 with at least one and up to four years of follow-up were studied. Data were collected and compared, including the pre- and post-surgery measures of weight, body mass index, glycosylated hemoglobin (HbA1c), and fasting blood glucose. Complete remission was defined as a fasting blood glucose level ≤100 mg/dL, an HbA1c ≤6 mg/dL, without use of antidiabetic medications. All patients showed significant reduction in body mass index following SG. Tight glycemic control was achieved among both diabetic and prediabetic patients. In this study, 88.14 per cent of all patients (diabetic and prediabetic) achieved complete resolution from their impaired glucose tolerance and T2DM and maintained normal blood glucose and HbA1C levels from one to four years postoperatively. SG is beneficial both in terms of short- and midterm weight loss and glucose control in both diabetic and prediabetic obese patients.

  3. Staple line leak with peritonitis after laparoscopic sleeve gastrectomy - a solution in one to six steps.

    Science.gov (United States)

    Špička, Petr

    2017-06-01

    Laparoscopic sleeve gastrectomy (LSG) is one of the most efficient bariatric interventions in morbidly obese patients. The most severe risk of this procedure seems to be the staple line leak, and the management of this complication can be very arduous. To share our experience in managing the staple line leak after LSG and to help to find the best procedure that should be preferred. In the 2010-2015 period we performed 223 LSG, with about 5 demonstrating severe complications - two patients with severe bleeding requiring revision surgery, and three patients with resection surface leak. We always primarily treated the staple line leak with a laparoscopic revision. Once the fistula did not spontaneously close after this treatment. A series of other methods were then indicated for this patient and only the sixth one resulted in the desirable therapeutic success. At first, our team opted for laparoscopic revision with drainage. The next procedure involved applying Ovesco and Boston clips. As a third method we performed abscess drainage through a nasobiliary tube inserted via gastroscopy. Due to failure we performed the second laparoscopic revision with staple line resuture, the next intervention was an open revision with fistula excision and suture, and finally we opted for the application of a self-expanding metallic stent, which proved to be definitely curative. Without any guidelines it is very difficult to determine the right procedure addressing the staple line leak after LSG. It depends mainly on the clinician's experience and is lengthy and often untraditional.

  4. A robust observer based on H∞ filtering with parameter uncertainties combined with Neural Networks for estimation of vehicle roll angle

    Science.gov (United States)

    Boada, Beatriz L.; Boada, Maria Jesus L.; Vargas-Melendez, Leandro; Diaz, Vicente

    2018-01-01

    Nowadays, one of the main objectives in road transport is to decrease the number of accident victims. Rollover accidents caused nearly 33% of all deaths from passenger vehicle crashes. Roll Stability Control (RSC) systems prevent vehicles from untripped rollover accidents. The lateral load transfer is the main parameter which is taken into account in the RSC systems. This parameter is related to the roll angle, which can be directly measured from a dual-antenna GPS. Nevertheless, this is a costly technique. For this reason, roll angle has to be estimated. In this paper, a novel observer based on H∞ filtering in combination with a neural network (NN) for the vehicle roll angle estimation is proposed. The design of this observer is based on four main criteria: to use a simplified vehicle model, to use signals of sensors which are installed onboard in current vehicles, to consider the inaccuracy in the system model and to attenuate the effect of the external disturbances. Experimental results show the effectiveness of the proposed observer.

  5. Spot Feeding Spheroidal Graphite Iron with Exothermic and Insulating Ram-Up Sleeves in Vertically Parted Moulds: Efficiency, Microstructure, Dimensional Accuracy, Deformation, and Driving Force and Feeding Criteria Identification

    DEFF Research Database (Denmark)

    Vedel-Smith, Nikolaj Kjelgaard

    feeders (ram-up sleeves) is investigated, showing that this new feeding approach can be used successfully to feed secluded sections inductile cast iron (EN-GJS-500-7). The feeder efficiency is tested using a high Silicon (Si) ductile iron (EN-GJS-450-10). The limits for the examined feeder configurations......Improvement of feeder technologies for energy savings in cast iron foundries is not only the title of the project behind this dissertation; it is a good idea that can improve casting yield and reduce production cost, and in turn strengthening the foundries competitive advantage. The approach...... of solidification. The dissertation provides a new approach to feeding secluded sections, a new characterisation of the underlying feeding forces, and new knowledge about the thermal deformation effects caused and controlled by feeding....

  6. Tazemetostat Rollover Study (TRuST): An Open-Label Rollover Study

    Science.gov (United States)

    2018-06-05

    Diffuse Large B-cell Lymphoma; Follicular Lymphoma; Malignant Rhabdoid Tumors (MRT); Rhabdoid Tumors of the Kidney (RTK); Atypical Teratoid Rhabdoid Tumors (ATRT); Synovial Sarcoma; Epitheliod Sarcoma; Mesothelioma; Advanced Solid Tumors

  7. A Randomized Comparison Between Staple-Line Oversewing Versus No Reinforcement During Laparoscopic Vertical Sleeve Gastrectomy.

    Science.gov (United States)

    Taha, Osama; Abdelaal, Mahmoud; Talaat, Mohamed; Abozeid, Mohamed

    2018-01-01

    Varieties of intraoperative methods such as oversewing of staple lines or other reinforcement products are used for preventing the laparoscopic vertical sleeve gastrectomy (LSG) complications. The aim of this study is to evaluate the complication rates of the gastric stapling alone versus stapling with oversewing invagination of the staple line in the LSG. This is a single-center randomized study, Patients were randomized to two groups, 200 patients underwent LSG without reinforcement of the staple line and 200 patients underwent LSG with oversewing of the staple line. All patients were followed up for 1 year. The data collected prospectively for statistical analysis included demographics, BMI, preoperative comorbidities, operative time, complications, and hospital stay. The overall mean operative age was 33.7 ± 9.4 years and mean BMI was 42.4 ± 4.3 kg/m 2 . Patient baseline characteristics (age, gender, weight, and BMI) and comorbidities were generally a nonsignificant different between the treatment arms. Surgical time was shorter in patients of the nonreinforced group (44.3 ± vs 51.3 ± 4.3 min; p < 0.01) with lower %EWL (73 ± 13.8 vs 80.7 ± 13.6%, p < 0.01). One patient in the nonreinforced group was complicated by gastric leak. The staple-line bleeding rate was significantly lower in patients underwent oversewing of the staple line during LSG (p < 0.05). Oversewing of the staple line during LSG is a nonexpansive and easy method to decrease the incidence and severity of the postoperative bleeding. However, it is time-consuming and should be performed by experienced surgeons to avoid the complications which may occur secondary to the seroserotomy suturing.

  8. Evaluation of oil-leakage of multi-layered resin-hose clamped with metal nipple and sleeve

    Science.gov (United States)

    Matsuoka, Kenta; Okubo, Kazuya; Fujii, Toru; Nakamura, Chihiro; Fujishita, Yushi; Kusu, Fuko; Matsushita, Masato; Yoshihara, Ryota

    2018-03-01

    The purpose of this study is to investigate the path of occurred oil-leakage of multi-layered resin-hose as one of multifunctional materials around the caulked joint with a metal nipple and sleeve when excessive cyclic internal pressure was applied onto the hose. Equivalent cyclic axial tensile force was substitutively applied to the hose, where same degree of normal stress was produced in longitudinal direction. Excessive 3 and 5 times of the standard load was applied to the hose. Cyclic loading was paused at every 1000 and 10000 cycles and then designed internal pressure was applied to the hose by a hand-operated pump with water in order to check whether the leakage was occurred around the joint and surface of the hose for safety evaluation. Cyclic fatigue life was defined as the number of loading cycles in which the leakage and the initial damage which was the passage of the ultrasonic wave was observed on the cyclic test. Test results showed the fatigue life at which leakage of water was observed was increased 20 times in case of K=3 compared to that in case of K=5. The cycles of initial damage detected by the ultrasonic wave were passed was increased 3.3 times in case of K=3 compared to that in case of K=5. The fluorescent agent penetrated from the core layer of resin hose to the reinforcement layer in which a half cross section along longitudinal direction in failed specimens was observed after the leak test. The original specimens had the gap between the resin-hose and the nipple and then the gap extended and connected during fatigue cyclic. In this study, it was observed that oil was leaked through narrow gap between the nipple and core layer of resin hose.

  9. Repair technique for steam generator tubes using electroforming

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Ho; Jeong, Hyun Kyu; Seo, Moon Hong

    2001-07-01

    Pickering B CANDU Unit 5 had experienced leakage at sleeve/tube joint due to severe and local pitting in 1992{delta}1993. One year later, OHT developed electrosleeving techniques for steam generator tube repair which was applied at Pickering B CANDU Unit 5, Oconee Unit 1 and Callaway in 1994, 1995 and 1999 respectively. In the results of electrosleeved tube test, electrosleeve materials were stronger than mother tubes in mechanical properties and corrosion resistance under design criteria. Two analytical models were originally developed for estimating the failure temperature under severe accident transients. Electrosleeve, a structural layer of fine grained nickel is electroformed onto the strike by circulating an aqueous solution of Ni sulfate or sulfamate with NiCO3. The patents published by FTI said that the electrolyte for electroforming the structural layer contains a pinning agent to inhibit growth of metal grains in the electroformed layer. The pinning agent contains phosphoric, phosphorous acid, molybdenum. In localization of electrosleeving, there are some problems like as 1)low plating rate, 2)high residual stress, 3)alloy composition, 4)low material properties at high temperature. Ni-Fe plating exhibit anomalous codeposition; that is less noble metal, Fe, deposits preferentially to the more noble metal, Ni. Ductility decrease and residual stress increase with increase of Fe content in plate layer. Addition of particle size of 10{delta}400{mu}m makes residual stress compressive in plate layer. Composite plating show excellent high temperature properties.

  10. Repair technique for steam generator tubes using electroforming

    International Nuclear Information System (INIS)

    Kim, Seung Ho; Jeong, Hyun Kyu; Seo, Moon Hong

    2001-07-01

    Pickering B CANDU Unit 5 had experienced leakage at sleeve/tube joint due to severe and local pitting in 1992δ1993. One year later, OHT developed electrosleeving techniques for steam generator tube repair which was applied at Pickering B CANDU Unit 5, Oconee Unit 1 and Callaway in 1994, 1995 and 1999 respectively. In the results of electrosleeved tube test, electrosleeve materials were stronger than mother tubes in mechanical properties and corrosion resistance under design criteria. Two analytical models were originally developed for estimating the failure temperature under severe accident transients. Electrosleeve, a structural layer of fine grained nickel is electroformed onto the strike by circulating an aqueous solution of Ni sulfate or sulfamate with NiCO3. The patents published by FTI said that the electrolyte for electroforming the structural layer contains a pinning agent to inhibit growth of metal grains in the electroformed layer. The pinning agent contains phosphoric, phosphorous acid, molybdenum. In localization of electrosleeving, there are some problems like as 1)low plating rate, 2)high residual stress, 3)alloy composition, 4)low material properties at high temperature. Ni-Fe plating exhibit anomalous codeposition; that is less noble metal, Fe, deposits preferentially to the more noble metal, Ni. Ductility decrease and residual stress increase with increase of Fe content in plate layer. Addition of particle size of 10δ400μm makes residual stress compressive in plate layer. Composite plating show excellent high temperature properties

  11. A rotating helical sealing joint capable of partially melting

    International Nuclear Information System (INIS)

    Martin, Jean; Ollier, J.-L.; Petit, Paul.

    1973-01-01

    A coagulated rotating helical joint providing gas and liquid tightness along a rotating shaft, comprising: a metal sleeve connected to the wall through which passes the rotating sleeve, an intermediate sleeve made of a fusible material, inert with respect to the fluid to be sealingly retained, and finally the rotating shaft provided with an engraved helical thread in register with the intermediate sleeve. Means are provided for regulating the intermediate sleeve temperature so that a thin melted film is formed on said intermediate sleeve when in contact with the rotating threaded shaft. This can be applied in the nuclear industry, including cases when the intermediate sleeve is constituted by the fluid itself, then in the solid state [fr

  12. Preoperative Detection of Sarcopenic Obesity Helps to Predict the Occurrence of Gastric Leak After Sleeve Gastrectomy.

    Science.gov (United States)

    Gaillard, Martin; Tranchart, Hadrien; Maitre, Sophie; Perlemuter, Gabriel; Lainas, Panagiotis; Dagher, Ibrahim

    2018-03-02

    Sleeve gastrectomy (SG) has become the primary procedure for many bariatric teams and staple-line leak represents its most feared complication. Sarcopenic obesity combines the risks of obesity and depleted lean mass leading possibly to an inferior surgical outcome after abdominal surgery. The aim of this study was to evaluate the existence of a potential link between radiologically determined sarcopenic obesity and staple-line leak risk after SG. A retrospective analysis of a prospective database was performed in consecutive patients undergoing SG as primary procedure. Total psoas muscles (TPA) and total visible muscles (TMA) areas were measured on a preoperative computed tomography (CT). Sarcopenia was defined as lowest tertile of skeletal muscular mass indexes (muscular areas over square of height) in each gender (using TPA or TMA). Multivariate analysis was performed to determine preoperative risk factors for staple-line leak. During the study period, 205 patients were included in the analysis. Median BMI was 40.8 kg/m 2 (34.2-49.6), and 9 patients (4.4%) presented a gastric leak. The sex-specific cut-offs for skeletal muscular mass index according to TPA were 8.2 cm 2 /m 2 for men and 6.08 cm 2 /m 2 for women. After multivariate analysis, preoperative weight (OR = 1043) and sarcopenia (TPA) (OR = 5204) were independent predictive factors for gastric leak. The present series suggests that CT scan-determined sarcopenic obesity is associated with increased risk of gastric leak after SG. This preoperatively radiological examination would be a useful clinical tool to tailor patient management according to gastric leak risk.

  13. Impact of concomitant laparoscopic sleeve gastrectomy and hiatal hernia repair on gastro-oesophageal reflux disease in morbidly obese patients

    Directory of Open Access Journals (Sweden)

    Harshit Garg

    2017-01-01

    Full Text Available Background: The aim of this study was to analyse the impact of hiatal hernia repair (HHR on gastro-oesophageal reflux disease (GERD in morbidly obese patients with hiatus hernia undergoing laparoscopic sleeve gastrectomy (LSG. Materials and Methods: It is a retrospective study involving ten morbidly obese patients with large hiatus hernia diagnosed on pre-operative endoscopy who underwent LSG and simultaneous HHR. The patients were assessed for symptoms of GERD using a Severity symptom score (SS questionnaire and anti-reflux medications. Results: Of the ten patients, five patients had GERD preoperatively. At the mean follow-up of 11.70 ± 6.07 months after surgery, four patients (80% showed complete resolution while one patient complained of persistence of symptoms. Endoscopy in this patient revealed resolution of esophagitis indicating that the persistent symptoms were not attributable to reflux. The other five patients without GERD remained free of any symptom attributable to GERD. Thus, in all ten patients, repair of hiatal hernia (HH during LSG led to either resolution of GERD or prevented any new onset symptom related to GER. Conclusion: In morbidly obese patients with HH with or without GERD undergoing LSG, repair of the hiatus hernia helps in amelioration of GERD and prevents any new onset GER. Thus, the presence of HH should not be considered as a contraindication for LSG.

  14. Effects of Laparoscopic Sleeve Gastrectomy on Central Obesity and Metabolic Syndrome in Indian Adults- A Prospective Study.

    Science.gov (United States)

    Sethi, Pulkit; Thillai, Manoj; Nain, Prabhdeep Singh; Ahuja, Ashish; Vayoth, Sudheer Othiyil; Khurana, Preetika

    2017-01-01

    Increasing incidence of obesity in Indian population has led to an exponential rise in the number of bariatric operations performed annually. Laparoscopic Sleeve Gastrectomy (LSG) has been proposed to cause rapid remission of Type 2 Diabetes Melitus (T2DM) and metabolic syndrome in a weight loss independent manner. To evaluate the effects of LSG on metabolic syndrome and central obesity in morbidly and severely obese Indian adults. Material and Methods: Study was conducted on 91 morbidly obese [Body Mass Index (BMI)>40 kg/m 2 ] and severely obese (BMI>35 kg/m 2 ) individuals who were suffering from diabetes, hypertension or dyslipidemia. The patients were followed up for six months and the trends of glycaemic control, mean blood pressure, lipid profile, weight loss parameters and changes in parameters of central obesity were studied. Weight loss was significant at three months postsurgery and was sustained through six months. There was significant improvement in glycaemic control leading to reduction in need for oral hypoglycaemic agents or insulin in majority of them and even discontinuation of these medications in few patients. Hypertension and dyslipidemia also showed an improving trend through six months postsurgery. There was a significant impact on reduction of central obesity in these patients as marked by significant reduction in waist to hip ratio. LSG produces sustainable weight loss with significant improvement in glycaemic status and control of metabolic syndrome in severe to morbidly obese patients. LSG is also efficacious in reducing central obesity in Indian population which is a major depressive ailment amongst obese individuals.

  15. Effects of sleeve gastrectomy on the composition and diurnal oscillation of gut microbiota related to the metabolic improvements.

    Science.gov (United States)

    Shao, Yikai; Shen, Qiwei; Hua, Rong; Evers, Simon S; He, Kai; Yao, Qiyuan

    2018-03-07

    Disruptions of the composition and diurnal oscillation of gut microbiota are involved in metabolic disorders. To identify alterations in both the composition and diurnal oscillation of gut microbiota after high-fat diet (HFD) feeding and sleeve gastrectomy (SG) related to host metabolic status. University laboratories. Twenty-one 6-week-old male C57 BL/6 J mice were randomized on an HFD (n = 14) or normal chow (NC, n = 7). After 14 weeks of feeding, HFD-induced obese mice were randomized to receive either SG or sham surgery (n = 7 in each group). Fecal samples were collected every 6 hours over a 24-hour period at 14 weeks of NC or HFD feeding and subsequently 8 weeks after surgery. The composition and diurnal oscillation of gut microbiota were characterized using next-generation Illumina sequencing of 16 S rDNA. HFD feeding led to adiposity, disrupted composition, and impaired diurnal oscillation of gut microbiota relative to NC. After surgery, SG mice had considerable weight loss, improved glucose tolerance, and insulin sensitivity compared with sham mice. SG restored the reduced richness and disruptions in the composition of gut microbiota. The diminished diurnal oscillation of gut microbiota was improved after SG. SG not only changed the disrupted composition of gut microbiota toward that of NC feeding, but also improved the dampened diurnal oscillation of gut microbiota due to HFD feeding. Copyright © 2018 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  16. Construction of new tie-in in the Bolivia-Brazil Gas Pipeline (GASBOL) using hot tapping techniques; Derivacao do Gasoduto Bolivia-Brasil com a tecnica de hot-tapping

    Energy Technology Data Exchange (ETDEWEB)

    Frisoli, Caetano [TRANSPETRO - PETROBRAS Transportes, Rio de Janeiro, RJ (Brazil); Frota, Cristiane Souto; Leite Filho, Ismael Casono; Lobao Filho, Jesualdo Pereira; Saavedra, Marcelo Curto [Transportadora Brasileira Gasoduto Bolivia-Brasil, S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    To supply 2,4 MM m3/d of natural gas to Tres Lagoas thermo electric plant, it was necessary to install a new delivery point of 12'' in the 32'' trunk line of Bolivia-Brazil gas pipeline. The most efficient method for executing new delivery points and maintenance repairs in pipelines is using the 'hot-tapping' technique, because there is no need to stop flow and blow down lines. This paper shows the project, specifications, planning and a detailed job execution to support this new city-gate, using a T split sleeve welded in the pipeline, explaining all the activities. Complex and innovative aspects related to the welding and inspection processes, executed in a API 5L X70 pipe at 92 kgf/cm{sup 2}, are also reported. (author)

  17. Staple Line Reinforcement During Laparoscopic Sleeve Gastrectomy: Absorbable Monofilament, Barbed Suture, Fibrin Glue, or Nothing? Results of a Prospective Randomized Study.

    Science.gov (United States)

    Carandina, S; Tabbara, M; Bossi, M; Valenti, A; Polliand, C; Genser, L; Barrat, Christophe

    2016-02-01

    Laparoscopic sleeve gastrectomy (LSG) is associated with serious complications, such as staple line (SL) leaks and bleeding. In order to prevent the occurrence of these complications, surgeons have advocated the need to strengthen the staple line. The aim of this randomized controlled study was to compare the efficacy of three different ways of strengthening of the SL in LSG in preventing surgical post-operative complications. Between April 2012 and December 2014, 600 patients (pts) scheduled for LSG were prospectively randomized into groups without SL reinforcement (group A) or with SL reinforcement including fibrin glue coverage (group B), or oversewn SL with imbricating absorbable (Monocryl™; group C) or barbed (V lock®) running suture (group D). Primary endpoints were post-operative leaks, bleeding, and stenosis, while secondary outcomes consisted of the time to perform the staple line reinforcement (SLR) and total operative time. Mean SLR operative time was lower for group B (3.4 ± 1.3 min) compared with that for groups C (26.8 ± 8.5 min) and D (21.1 ± 8.4 min) (p running suture or with fibrin glue, is an unrewarding surgical act with the sole effect of prolonging the operative time.

  18. Laparoscopic sleeve gastrectomy after failed gastric banding: is it really effective? Six years of follow-up.

    Science.gov (United States)

    Carandina, Sergio; Genser, Laurent; Bossi, Manuela; Polliand, Claude; Tabbara, Malek; Barrat, Christophe

    2017-07-01

    Laparoscopic sleeve gastrectomy (LSG) has become a valuable surgical option to rescue laparoscopic adjustable gastric banding (LAGB) failures. The aim of this study was to determine whether conversion to LSG after failed LAGB (CLSG) is a well-tolerated and effective rescue procedure compared with primary LSG (PLSG) in the long term. University hospital, France. A retrospective review of data concerning consecutive patients receiving a LSG between February 2008 and December 2014 was conducted. Mortality, postoperative complications, and weight loss outcomes were analyzed. Of 701 LSG, 601 (85.7%) were PLSG and 100 (14.3%) were CLSG. The mortality rate was 0%. Overall morbidity was comparable between the primary and conversion group (10% versus 6%, P = .27). The mean percentage of excess weight loss at 3, 36, and 72 months was 34.9%, 72.1%, and 57.2% after PLSG and 22.6%, 51.2% and 29.8% after CLSG (P<.05). The failure rate (mean percentage of excess weight loss<50%) was higher in the CLSG group during the first 5 postoperative years (P < .001) with more than two thirds of the CLSG considered as having failed at 60 months. Patients who underwent band ablation as a result of insufficient weight loss or weight regain presented the worst results after conversion to LSG. In this study, the conversion of failed LAGB to LSG in 2 steps indicated a safety profile comparable to that of primary LSG but was significantly less effective from the early postoperative course (3 mo) up to 6 years postoperatively. CLSG may not be the best option because a third operation may be needed as a result of insufficient weight loss. Copyright © 2017 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  19. Gastroesophageal reflux disease and Barrett's esophagus after laparoscopic sleeve gastrectomy: a possible, underestimated long-term complication.

    Science.gov (United States)

    Genco, Alfredo; Soricelli, Emanuele; Casella, Giovanni; Maselli, Roberta; Castagneto-Gissey, Lidia; Di Lorenzo, Nicola; Basso, Nicola

    2017-04-01

    Morbidly obese patients are affected by gastroesophageal reflux disease (GERD) and hiatal hernia (HH) more frequently than lean patients. Because of conflicting results, the indication to sleeve gastrectomy (SG) in patients with GERD is still debated. To evaluate the incidence of GERD on the basis of clinical, endoscopic, and histologic data in patients undergoing SG. University hospital, Rome, Italy. From July 2007 to January 2010, 162 patients underwent primary SG. Preoperatively all patients underwent visual analogue scale (VAS) evaluation of GERD symptoms, proton pump inhibitors (PPIs) consumption recording, and esophagogastroduodenoscopy (EGD). Stomach resection started 6 cm from pylorus on a 48Fr bougie. Staple line was reinforced by an oversewing suture. A postoperative clinical control with VAS evaluation, PPI consumption, and EGD was proposed to all patients. Three patients were excluded because of the occurrence of major postoperative complications. A total of 110 patients accepted to take part in the study (follow-up rate: 69.1%). At a mean 58 months of follow-up, incidence of GERD symptoms, VAS mean score, and PPI intake significantly increased compared with preoperative values (68.1% versus 33.6%: Preflux was found in 73.6% and 74.5% of cases, respectively. A significant increase in the incidence and in the severity of erosive esophagitis (EE) was evidenced, whereas nondysplastic Barrett's esophagus (BE) was newly diagnosed in 19 patients (17.2%). No significant correlations were found between GERD symptoms and endoscopic findings. In the present series the incidence of EE and of BE in SG patients was considerably higher than that reported in the current literature, and it was not related to GERD symptoms. Endoscopic surveillance after SG should be advocated irrespective of the presence of GERD symptoms. Copyright © 2017 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  20. 3D Volumetry and its Correlation Between Postoperative Gastric Volume and Excess Weight Loss After Sleeve Gastrectomy.

    Science.gov (United States)

    Hanssen, Andrés; Plotnikov, Sergio; Acosta, Geylor; Nuñez, José Tomas; Haddad, José; Rodriguez, Carmen; Petrucci, Claudia; Hanssen, Diego; Hanssen, Rafael

    2018-03-01

    The volume of the postoperative gastric remnant is a key factor in excess weight loss (EWL) after sleeve gastrectomy (SG). Traditional methods to estimate gastric volume (GV) after bariatric procedures are often inaccurate; usually conventional biplanar contrast studies are used. Thirty patients who underwent SG were followed prospectively and evaluated at 6 months after the surgical procedure, performing 3D CT reconstruction and gastric volumetry, to establish its relationship with EWL. The gastric remnant was distended with effervescent sodium bicarbonate given orally. Helical CT images were acquired and reconstructed; GV was estimated with the software of the CT device. The relationship between GV and EWL was analyzed. The study allowed estimating the GV in all patients. A dispersion diagram showed an inverse relationship between GV and %EWL. 55.5% of patients with GV ≤ 100 ml had %EWL 25-75% and 38.8% had an %EWL above 75% and patients with GV ≥ 100 ml had an %EWL under 25% (50% of patients) or between 25 and 75% (50% of this group). The Pearson's correlation coefficient was R = 6.62, with bilateral significance (p ≤ .01). The Chi-square result correlating GV and EWL showed a significance of .005 (p ≤ .01). The 3D reconstructions showed accurately the shape and anatomic details of the gastric remnant. 3D volumetry CT scans accurately estimate GV after SG. A significant relationship between GV and EWL 6 months after SG was established, seeming that GV ≥ 100 ml at 6 months of SG is associated with poor EWL.

  1. Clinical evaluation of C-reactive protein and procalcitonin for the early detection of postoperative complications after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Frask, Agata; Orłowski, Michał; Dowgiałło-Wnukiewicz, Natalia; Lech, Paweł; Gajewski, Krzysztof; Michalik, Maciej

    2017-06-01

    Among the most common early complications after bariatric surgery are anastomosis leak and bleeding. In order to react quickly and perform accurate treatment before the clinical signs appear, early predictors should be found. In the study C-reactive protein (CRP) and procalcitonin (PCT) levels were investigated. Characterized by a relatively short half-life, they can predict surgical complications. To develop and implement certain standards for early detection of complications. The study involved 319 adults who underwent laparoscopic sleeve gastrectomy (LSG) as a surgical intervention for morbid obesity at the Department of General Surgery of Ceynowa Hospital in Wejherowo. Every patient had CRP and PCT levels measured before the surgery and on the 1 st and 2 nd postoperative day (POD). Early postoperative complications occurred in 19 (5.96%) patients. Septic and non-septic complications occurred in 3 and 16 patients respectively. Among the patients with septic postoperative complications CRP level increased significantly on the 2 nd POD compared to the remainder (p = 0.0221). Among the patients with non-septic postoperative complications CRP level increased significantly on the 1 st and 2 nd POD compared to the remainder. Among the patients with septic and non-septic postoperative complications PCT level increased significantly on the 2 nd POD compared to the remainder. The CRP and PCT level are supposed to be relevant diagnostic markers to predict non-septic and septic complications after LSG.

  2. Does Weight Gain During the Operation Wait Time Have an Impact on Weight Loss After Laparoscopic Sleeve Gastrectomy?

    Science.gov (United States)

    Cayci, Haci Murat; Erdogdu, Umut Eren; Karaman, Kerem; Budak, Ersin; Taymur, İbrahim; Buyukuysal, Cagatay

    2017-02-01

    The effect of preoperative weight changes on postoperative outcomes after bariatric surgery remains inconclusive. The aim of the present study was to evaluate the effect of preoperative weight gain on postoperative weight loss outcomes after laparoscopic sleeve gastrectomy (SG). Ninety-two morbidly obese patients undergoing SG from January 2014 to April 2016 were separated into two groups according to whether they gained weight or not during the waiting time prior to surgery. Thirty-nine patients (42.4 %) gained weight during the waiting time and 53 patients (57.6 %) did not. The median body mass index (BMI; kg/m 2 ) at surgery was significantly higher in weight-gained patients (47.8 (min-max, 40-62)) compared to patients who had not gained weight (45.10 (min-max, 41-67)), (P = 0.034). No significant difference was found between the two groups regarding the distribution of age, gender, family history of obesity, existence of comorbidity, smoking, weight gain during childhood or adulthood, preoperative Beck depression and Beck anxiety scores, waiting time period, and body weight at the initial visit (P > 0.05). The ASA I score was higher in weight-gained patients whereas ASA II score was higher in those who did not gain, and the difference was significant (P = 0.046). Postoperative % BMI loss and % weight loss were not significantly different between the two groups at the first, third, sixth months, and the end of the first year (P > 0.05). Weight gain during waiting time has no negative impact on % weight loss and % BMI loss after SG.

  3. Comparison of percentage excess weight loss after laparoscopic sleeve gastrectomy and laparoscopic adjustable gastric banding

    Science.gov (United States)

    Bobowicz, Maciej; Lech, Paweł; Orłowski, Michał; Siczewski, Wiaczesław; Pawlak, Maciej; Świetlik, Dariusz; Witzling, Mieczysław; Michalik, Maciej

    2014-01-01

    Introduction Laparoscopic sleeve gastrectomy (LSG) and laparoscopic adjustable gastric banding (LAGB) are acceptable options for primary bariatric procedures in patients with body mass index (BMI) 35–55 kg/m2. Aim The aim of this study is to compare the effects of these two bariatric procedures 6, 12 and 24 months after surgery. Material and methods Two hundred and two patients were included 72 LSG and 130 LAGB patients. The average age was 38.8 ±11.9 and 39.4 ±10.4 years in LSG and LAGB groups, with initial BMI of 44.1 kg/m2 and 45.2 kg/m2, p = NS. Results The mean percentage of excess weight loss (%EWL) at 6 months for LSG vs. LAGB was 36.3% vs. 30.1% (p = 0.01) and at 12 months was 43.8% vs. 34.6% (p = 0.005). The greatest difference in the mean %EWL at 12 months was observed in patients with initial BMI of 40–49.9 kg/m2 in favor of LSG (47.5% vs. 35.6%; p = 0.01). Two years after surgery there was no advantage of LSG and in the subgroup of patients with BMI 50–55 kg/m2 there was a trend in favor of LAGB (57.2% vs. 30%; p = 0.07). The multiple regression model of independent variables (age, gender, initial BMI and the presence of comorbidities) proved insignificant in prediction of the best outcome in means of %EWL for either operative modality. None of these factors in the logistic regression model could determine the type of surgery that should be used in particular patients. Conclusions During the first 2 years after surgery, the best results were obtained in women with lower BMI undergoing LSG surgery. The LSG provides greater %EWL after a shorter period of time though the difference decreases in time. PMID:25337157

  4. Византийские (средиземноморские мечи с перекрестьями с муфтой IX—XI вв. / Byzantine (Mediterranian 9th — 11th century swords with sleeve cross-guards

    Directory of Open Access Journals (Sweden)

    Baranov G.V.

    2017-12-01

    Full Text Available The article reviews such as a group of early medieval swords with cross-guards having three main elements: a collar, a quillon and a sleeve. A significant number of such swords as well as separate cross-guards were found in Eastern Europe and are dated from the 9th c. (possibly as early as the second half of the 8th c. to the 11th c. This design of cross-guards is typical of the Mediterranean region. Its wide spread across Eastern Europe should be linked to the influence of the Byzantine Empire, where comparable items can be found in art. The paper categorizes cross-guards of this kind into three main types and describes the principal trends in their evolution: reduction of collar and sleeve height and increasing quillon length. Two types of pommels in such swords are described, as well as remaining elements of scabbards.

  5. System and method for manufacture of airfoil components

    Science.gov (United States)

    Moors, Thomas Michael

    2016-11-29

    Embodiments of the present disclosure relate generally to systems and methods for manufacturing an airfoil component. The system can include: a geometrical mold; an elongated flexible sleeve having a closed-off interior and positioned within the geometrical mold, wherein the elongated flexible sleeve is further positioned to have a desired geometry; an infusing channel in fluid communication with the closed-off interior of the elongated flexible sleeve and configured to communicate a resinous material thereto; a vacuum channel in fluid communication with the closed-off interior of the elongated flexible sleeve and configured to vacuum seal the closed-off interior of the elongated flexible sleeve; and a glass fiber layer positioned within the closed-off interior of the elongated flexible sleeve.

  6. PWR pressurizer with heaters well which can be obturate and sealing process

    International Nuclear Information System (INIS)

    Godin, B.; Guicherd, L.

    1991-01-01

    Each heater well is prolongated at the end located outer the pressurizer containment by a sleeve internally tapped which is prolongated at the other end by a guiding and fixation sleeve for welding the heater. The heater well can be obturated by a threaded plug introduce in the tapped part of the sleeve after cutting the welding sleeve and extraction of the heater [fr

  7. Innovation pressure : service companies race to improve their horizontal multi-frac completion tools and techniques

    Energy Technology Data Exchange (ETDEWEB)

    Chandler, G.

    2010-11-15

    This article described innovations in horizontal multi-frac completion tools and techniques that service companies are providing in the field. BJ Services has developed coiled tubing technology for annular fracing in cased-hole horizontal wells, which enables producers to complete with closer spacing, and frac sleeves that form an integral part of the casing string. Trican Well Service Ltd. recommends pumping through casing to create an unobstructed conduit, reducing friction and allowing the high pressure needed to create complex fractures. The Burst Port System is designed for selective fracturing: integrated casing collars that contain pre-milled ports are placed into the horizontal well casing; the C2C, a selective fracturing cup tool with a unique pressure equalization valve, straddles the port; and pressure is built up the designated burst point, leaving an isolated conduit to the formation. Recent chemical innovations include ecologically safe frac fluids and fluids designed to work in cold temperatures. The Viking PW (produced water) system can accommodate produced water, recycled water, and recycled oil-based frac systems and tolerates other contaminants. Non-toxic EcoClean fluids protect water wells and aquifers during treatments. A new frac fluid modifies the surface property of proppant, allowing deeper penetration with less settling and banking. Advances in well simulation technology, micro-seismic techniques that can listen and locate fracing events in real time, and directional drillers were also described. Low gas prices are inspiring companies to improve efficiency ad lower costs, which is creating a greater emphasis on development. 2 figs.

  8. Results from the Evaluation of the Massachusetts Nursing Home Connection Program

    Science.gov (United States)

    1989-10-01

    For the rollovers, the midpoint data was collected at the time of transfer to the new system of care. The basic comparisons were from admission to...claims data from both the Medicare and Medicaid programs as well as nursing home data from the Massachusetts Medicaid Medical Information System ...Patients Rollovers )ieaes of nervus systern 13 15 Dementia 31 35 CVA 27 29 HIP 18 1 5 b Cancer 07 041) Neurologic disorders 6(30 62 )epression 03 04

  9. Ultrasonic inspection of tube to tube plate welds

    International Nuclear Information System (INIS)

    Telford, D.W.; Peat, T.S.

    1985-01-01

    To monitor the deterioration of a weld between a tube and tube plate which has been repaired by a repair sleeve inside the tube and brazed at one end to the tube, ultrasound from a crystal at the end of a rod is launched, in the form of Lamb-type waves, into the tube through the braze and allowed to travel along the tube to the weld and be reflected back along the tube. The technique may also be used for the type of heat exchanger in which, during construction, the tubes are welded to the tube plate via external sleeves in which case the ultrasound is used in a similar manner to inspect the sleeve/tube plate weld. an electromagnetic transducer may be used to generate the ultrasound. The ultrasonic head comprising the crystal and an acoustic baffle is mounted on a Perspex (RTM) rod which may be rotated by a stepping motor. Echo signals from the region of deterioration may be isolated by use of a time gate in the receiver. The device primarily detects circumferentially orientated cracks, and may be used in heat exchangers in nuclear power plants. (author)

  10. Percutaneous Management of Accidentally Retained Foreign Bodies During Image-Guided Non-vascular Procedures: Novel Technique Using a Large-Bore Biopsy System

    Energy Technology Data Exchange (ETDEWEB)

    Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Garnon, Julien, E-mail: juleiengarnon@gmail.com [Hôpitaux Universitaires de Strasbourg, HUS, Department of Interventional Radiology, Nouvel Hôpital Civil (France); Ramamurthy, Nitin, E-mail: nitin-ramamurthy@hotmail.com [Norfolk and Norwich University Hospital, Department of Radiology (United Kingdom); Tsoumakidou, Georgia, E-mail: georgia.tsoumakidou@chru-strasbourg.fr; Caudrelier, Jean, E-mail: jean.caudrelier@chru-strasbourg.fr; Thénint, Marie-Aude, E-mail: marie-aude.thenint@chru-strasbourg.fr; Rao, Pramod, E-mail: pramodrao@me.com; Koch, Guillaume, E-mail: guillaume.koch@chru-strasbourg.fr; Gangi, Afshin, E-mail: gangi@unistra.fr [Hôpitaux Universitaires de Strasbourg, HUS, Department of Interventional Radiology, Nouvel Hôpital Civil (France)

    2016-07-15

    ObjectiveTo describe a novel percutaneous image-guided technique using a large-bore biopsy system to retrieve foreign bodies (FBs) accidentally retained during non-vascular interventional procedures.Materials and MethodsBetween May 2013 and October 2015, five patients underwent percutaneous retrieval of five iatrogenic FBs, including a biopsy needle tip in the femoral head following osteoblastoma biopsy and radiofrequency ablation (RFA); a co-axial needle shaft within a giant desmoid tumour following cryoablation; and three post-vertebroplasty cement tails within paraspinal muscles. All FBs were retrieved immediately following original procedures under local or general anaesthesia, using combined computed tomography (CT) and fluoroscopic guidance. The basic technique involved positioning a 6G trocar sleeve around the FB long axis and co-axially advancing an 8G biopsy needle to retrieve the FB within the biopsy core. Retrospective chart review facilitated analysis of procedures, FBs, technical success, and complications.ResultsMean FB size was 23 mm (range 8–74 mm). Four FBs were located within 10 mm of non-vascular significant anatomic structures. The basic technique was successful in 3 cases; 2 cases required technical modifications including using a stiff guide-wire to facilitate retrieval in the case of the post-cryoablation FB; and using the central mandrin of the 6G trocar to push a cement tract back into an augmented vertebra when initial retrieval failed. Overall technical success (FB retrieval or removal to non-hazardous location) was 100 %, with no complications.ConclusionPercutaneous image-guided retrieval of iatrogenic FBs using a large-bore biopsy system is a feasible, safe, effective, and versatile technique, with potential advantages over existing methods.

  11. Submarine Propulsion Shaft Life: Probabilistic Prediction and Extension through Prevention of Water Ingress

    Science.gov (United States)

    2014-06-01

    625 (an Inconel ) sleeve. These sleeves exhibit exceptional corrosion performance, and are used as the wear surfaces in contact with the lubricated...it exits the stern tube bearing. There is an alloy 625 ( Inconel ) sleeve, used as a wear surface for the bearing interaction, as seen in the drawing...Industry Day at MIT, October 13, 2011. Alloy 625 sleeve Mild steel shaft Typical Corrosion Area Epoxy Filler Glass Reinforced Plastic Cover

  12. HEALING OF MICROVENOUS PTFE PROSTHESES IMPLANTED INTO THE RAT FEMORAL VEIN

    NARCIS (Netherlands)

    VANDERLEI, B; DIJK, F; JONGEBLOED, WL; ROBINSON, PH; Bartels, H.

    44 PTFE prostheses (Gore-Tex(R); ID 1 mm) were implanted into rats' femoral veins by means of the sleeve anastomotic technique and were evaluated at regular intervals from 1 h up till 24 weeks after implantation by means of light and electron microscopy to study in detail their healing process. All

  13. Improvements in nuclear fuel assembly cages

    Energy Technology Data Exchange (ETDEWEB)

    Eaton, C.W.; Seeley, T.A.; Ince, G.; Speakman, W.T.

    1986-03-12

    The fuel pin/guide tube supporting grids of an assembly cage for a multi pin fuel element or a reflector element for a stringer are mounted in the moderator sleeve by way of mounting assemblies engaged in grooves machined into the interior surface of the sleeve, each mounting assembly including a split ring which is assembled into its groove by being radially contracted, pushed along the sleeve into registry with the groove and allowed to radially expand. The split ring may carry burnable neutron absorber. The region of the sleeve between two adjacent grids may be of smaller internal diameter than the remainder of the sleeve.

  14. Liver Function in Patients With Nonalcoholic Fatty Liver Disease Randomized to Roux-en-Y Gastric Bypass Versus Sleeve Gastrectomy: A Secondary Analysis of a Randomized Clinical Trial.

    Science.gov (United States)

    Kalinowski, Piotr; Paluszkiewicz, Rafał; Ziarkiewicz-Wróblewska, Bogna; Wróblewski, Tadeusz; Remiszewski, Piotr; Grodzicki, Mariusz; Krawczyk, Marek

    2017-11-01

    The aim of the study was to compare the influence of sleeve gastrectomy (SG) versus Roux-en-Y gastric bypass (RYGB) on liver function in bariatric patients with non-alcoholic fatty liver disease (NAFLD) in a randomized clinical trial (NCT01806506). Rapid weight loss and malabsorption after bariatric surgery in patients with NAFLD or steatohepatitis (NASH) may impair liver function. Sixty-six morbidly obese patients randomized to SG or RYGB were included in a secondary outcome analysis. Intraoperative liver biopsies were categorized with NAFLD Activity Score (NAS) and liver function tests were done before surgery and after 1, 6 and 12 months. NASH was present in 54.5% RYGB and 51.5% SG patients (P > 0.05). At 12 months excess weight loss was 68.7 ± 19.7% after SG and 62.8 ± 18.5% after RYGB (P > 0.05). At 1 month international normalized ratio (INR) increased after RYGB (0.98 ± 0.05 vs 1.14 ± 0.11; P liver function than after SG.

  15. Handling apparatus for a nuclear reactor fuel assembly

    International Nuclear Information System (INIS)

    Shallenberger, J.M.; Hornak, L.P.; Desmarchais, W.E.

    1978-01-01

    An apparatus is disclosed for handling radioactive fuel assembly during transfer operations. The radioactive fuel assembly is drawn up into a shielding sleeve which substantially reduces the level of radioactivity immediately surrounding the sleeve thereby permitting direct access by operating personnel. The lifting assembly which draws the fuel assembly up within the shielding sleeve is mounted to and forms an integral part of the handling apparatus. The shielding sleeve accompanies the fuel assembly during all of the transfer operations

  16. Safety System for Controlling Fluid Flow into a Suction Line

    Science.gov (United States)

    England, John Dwight (Inventor); Kelley, Anthony R. (Inventor); Cronise, Raymond J. (Inventor)

    2018-01-01

    A safety system includes a sleeve fitted within a pool's suction line at its inlet. The sleeve terminates with a plate that resides within the suction line. The plate has holes formed therethrough. A housing defining distinct channels is fitted in the sleeve so that the distinct channels lie within the sleeve. Each of the distinct channels has a first opening on one end thereof and a second opening on another end thereof. The second openings reside in the sleeve. The first openings are in fluid communication with the water in the pool, and are distributed around a periphery of an area of the housing that prevents coverage of all the first openings when a human interacts therewith. A first sensor is coupled to the sleeve to sense pressure therein, and a second pressure sensor is coupled to the plate to sense pressure in one of the plates' holes.

  17. Control rod cluster with removable rods for nuclear fuel assembly

    International Nuclear Information System (INIS)

    Denizou, J.P.

    1989-01-01

    For each removable control rod, the open end section of the sleeve has a certain length of reduced diameter with openings in its wall. The top end of the rod is joined to an extension tube that surrounds the shaft over part of its lenght. This extension tube fits over the reduced part of the sleeve when the shaft is screwed into the bore of the sleeve. Rotation of the rod in the sleeve is prevented by deforming the extension tube locally in the openings of the end part of the sleeve. The rod is dismantled by exerting a torque on it using a gripping area near the end of the rod [fr

  18. Sleeve Gastrectomy: Correlation of Long-Term Results with Remnant Morphology and Eating Disorders.

    Science.gov (United States)

    Tassinari, Daniele; Berta, Rossana D; Nannipieri, Monica; Giusti, Patrizia; Di Paolo, Luca; Guarino, Daniela; Anselmino, Marco

    2017-11-01

    Remnant dimension is considered one of the crucial elements determining the success of sleeve gastrectomy (SG), and dilation of the gastric fundus is often believed to be the main cause of failure. The main outcome of this study is to find correlations between remnant morphology in the immediate post-operative stage, its dilation in years, and the long-term results. The second purpose aims to correlate preoperative eating disorders, taste alteration, hunger perception, and early satiety with post-SG results. Remnant morphology was evaluated, in the immediate post-operative stage and over the years (≥2 years), through X-ray of the oesophagus-stomach-duodenum calculating the surface in anteroposterior (AP) and right anterior oblique projection (RAO). Presurgery diagnosis of eating disorders and their evaluation through "Eating Disorder Inventory-3" (EDI3) during follow-up were performed. Change in taste perception, sense of appetite, and early satiety were evaluated. Patients were divided into two groups: "failed SGs (EWL50%). There were a total of 50 patients (37 F, 13 M), with mean age 52 years, preoperative weight 131 ± 21.8 kg, and BMI 47.4 ± 6.8 kg/m 2 . Post-operative remnant mean dimensions overlapped between the two groups. On a long-term basis, an increase of 57.2 and 48.4% was documented in the AP and RAO areas respectively. In "failed" SGs, dilation was significantly superior to "efficient" SGs (AP area 70.2 vs 46.1%; RAO area 59.3 vs 39%; body width 102% vs 41.7%). Preoperative eating disorders were more present in efficient SGs than in failed SGs with the exception of sweet eating. There were no significant changes to taste perception during follow-up. Fifty-two percent of efficient SGs vs 26% of failed SGs reported a persistent lack of sense of hunger; similarly, 92.5 vs 78% declared the persistence of a sense of early satiety. The two groups did not statistically differ as far as all the variables of the EDI3 are concerned. On a long

  19. Wholesale funding, coordination, and credit risk

    OpenAIRE

    Zhang, Lei; Zhang , Lin; Zheng, Yong

    2013-01-01

    We use the global games approach to study key factors affecting the credit risk\\ud associated with roll-over of bank debt. When creditors are heterogenous, these include\\ud the extent of short-term borrowing and capital market liquidity for repo financing.\\ud Specifically, in a model with a large institutional creditor and a continuum of small\\ud creditors independently making their roll-over decisions based on private information,\\ud we find that increasing the proportion of short-term debt and/...

  20. Short- and mid-term outcomes of sleeve gastrectomy for morbid obesity: the experience of the Spanish National Registry.

    Science.gov (United States)

    Sánchez-Santos, Raquel; Masdevall, Carlos; Baltasar, Aniceto; Martínez-Blázquez, Candido; García Ruiz de Gordejuela, Amador; Ponsi, Enric; Sánchez-Pernaute, Andres; Vesperinas, Gregorio; Del Castillo, Daniel; Bombuy, Ernest; Durán-Escribano, Carlos; Ortega, Luis; Ruiz de Adana, Juan Carlos; Baltar, Javier; Maruri, Ignacio; García-Blázquez, Emilio; Torres, Antonio

    2009-09-01

    Reports on laparoscopic sleeve gastrectomy (LSG) communicate very good short-term results on very high-risk morbid obese patients. However, mid- and long-term results are still unknown. A National Registry has been created in Spain to achieve information on the outcomes of this bariatric procedure. Data were obtained from 17 centers and collected in a database. Technical issues, preoperative comorbid conditions, hospital stay, early and late complications, and short- and mid-term weight loss were analyzed. Five hundred forty patients were included; 76% were women. Mean BMI was 48.1 +/- 10. Mean age was 44.1 +/- 11.8. Morbidity rate was 5.2% and mortality rate 0.36%. Complications presented more frequently in superobese patients (OR, 2.8 (1.18-6.65)), male (OR, 2.98 (1.26-7.0)), and patients >55 years old (OR, 2.8 (1.14-6.8)). Staple-line reinforcement was related to a lower complication rate (3.7 vs 8.8%; p = 0.039). Mean hospital stay was 4.8 +/- 8.2 days. Mean follow-up was 16.5 +/- 10.6 months (1-73). Mean percent excess BMI loss (EBL) at 3 months was 38.8 +/- 22, 55.6 +/- 8 at 6 months, 68.1 +/- 28 at 12 months, and 72.4 +/- 31 at 24 months. %EBL was superior in patients with lower initial BMI and lower age. Bougie caliber was an inverse predictive factor of %EBL at 12 and 24 months (RR, 23.3 (11.4-35.2)). DM is remitted in 81% of the patients and HTA improved in 63.2% of them. A second-stage surgery was performed in 18 patients (3.2%). LSG provides good short- and mid-term results with a low morbid-mortality rate. Better results are obtained in younger patients with lowest BMI. Staple-line reinforcement and a thinner bougie are recommended to improve outcome.

  1. Gas cooled high temperature reactor with a heap of pebble shaped fuel elements and absorber rods which can be driven directly into the heap of pebbles

    International Nuclear Information System (INIS)

    Elter, C.; Schmitt, H.; Schoening, J.; Weicht, U.

    1980-01-01

    The absorber rod for the graphite moderated, helium cooled reactor is cylindrical and has a tip in the shape of the frustrum of a cone. It consists of three coaxially arranged sleeve tubes made of steel, the inner and centre sleeve tubes surrounding the absorber part (B4C) so as to be gastight. The inner sleeve tube represents the supporting tube and is cooled by cold gas, as is the annular gap between the centre and outer sleeve tube. (RW) [de

  2. Nuclear reactor spacer assembly

    International Nuclear Information System (INIS)

    Anthony, A.J.; Groves, M.D.

    1979-01-01

    A fuel assembly for a nuclear reactor is disclosed wherein the fuel element receiving and supporting grid is comprised of a first metal, the guide tubes which pass through the grid assembly are comprised of a second metal and the grid is supported on the guide tubes by means of expanded sleeves located intermediate the grid and guide tubes. The fuel assembly is fabricated by inserting the sleeves, of initial outer diameter commensurate with the guide tube outer diameters, through the holes in the grid assembly provided for the guide tubes and thereafter expanding the sleeves radially outwardly along their entire length such that the guide tubes can subsequently be passed through the sleeves. The step of radial expansion, as a result of windows provided in the sleeves having dimensions commensurate with the geometry of the grid, mechanically captures the grid and simultaneously preloads the sleeve against the grid whereby relative motion between the grid and guide tube will be precluded

  3. Glove boxes

    International Nuclear Information System (INIS)

    Eisert, G.A.

    1979-01-01

    An arrangement for effecting access for performing work within a glove box comprises an elongate arm-length impermeable flexible sleeve, a fitting having an aperture therethrough, adapted to be secured in sealing relation in a port, in a wall of the glove box, the fitting including an outwardly extending lip having at least one continuous groove extending around its outer periphery, one end of the sleeve extending through the aperture in fitting and being folded back against the outer periphery of the lip, a resilient fastening ring securing the sleeve in sealing engagement in the groove, clamping means securing the sleeves to the lip and a glove secured in sealing relation via a bushing to the other end of the sleeve. (author)

  4. In vivo dosimetry of high-dose-rate brachytherapy: Study on 61 head-and-neck cancer patients using radiophotoluminescence glass dosimeter

    International Nuclear Information System (INIS)

    Nose, Takayuki; Koizumi, Masahiko; Yoshida, Ken; Nishiyama, Kinji; Sasaki, Junichi; Ohnishi, Takeshi; Peiffert, Didier

    2005-01-01

    Purpose: The largest in vivo dosimetry study for interstitial brachytherapy yet examined was performed using new radiophotoluminescence glass dosimeters (RPLGDs). Based on the results, a dose prescription technique achieving high reproducibility and eliminating large hyperdose sleeves was studied. Methods and materials: For 61 head-and-neck cancer patients who underwent high-dose-rate interstitial brachytherapy, new RPLGDs were used for an in vivo study. The Paris System was used for implant. An arbitrary isodose surface was selected for dose prescription. Locations of 83 dosimeters were categorized as on target (n = 52) or on nontarget organ (n = 31) and were also scaled according to % basal dose isodose surface (% BDIS). Compatibility (measured dose/calculated dose) was analyzed according to location. The hyperdose sleeve was assessed in terms of prescription surface expressed in % BDIS. Results: The spread of compatibilities was larger for on nontarget organ (1.06 ± 0.32) than for on target (0.87 ± 0.17, p = 0.01). Within on target RPLGDs, compatibility on 77% and < 95% BDIS for reproducibility and elimination of excessive hyperdose sleeve. For organs at risk, radioprotection should be considered even when calculated dose seems sufficiently low. Further development of planning software is necessary to prevent overestimation

  5. Tip of the iceberg

    DEFF Research Database (Denmark)

    Deriabyn, M. V.; Hjorth, Poul G.

    2009-01-01

    We study the stability and dynamics of melting icebergs. Specifically, we address the 'toppling' or 'rollover' observed for floating icebergs. The rollover is thought to occur because the ocean melts the iceberg from below, causing its overall mass and mass distribution to change with time. We...... model the evolution of equilibrium positions for a general homogeneous body afloat in an ideal fluid, as this homogeneous body is subjected to 'melting', i.e. a slow removal of material from the submerged part. If this process is the dominating melting mechanism, can the likelihood of a toppling...

  6. 78 FR 17082 - Airworthiness Directives; Rolls-Royce Deutschland Ltd & Co KG Turbojet Engines

    Science.gov (United States)

    2013-03-20

    ... flight. (5) If you find any broken bolt in the HPT shaft air seal sleeve, visually inspect the HPT stage... assembly, high pressure turbine (HPT) bearing support assembly and HPT air seal sleeve bolts identified... turbine (HPT) bearing support assembly, and HPT air seal sleeve within 100 engine cycles-in-service. (2...

  7. 77 FR 66769 - Airworthiness Directives; Rolls-Royce Deutschland Ltd & Co KG Turbojet Engines

    Science.gov (United States)

    2012-11-07

    .... (5) If any bolt is found broken in the HPT shaft air seal sleeve, inspect the HPT stage 1 disc for...) bearing support assembly and HPT air seal sleeve bolts identified that, before installation, those bolts... assembly, high-pressure turbine (HPT) bearing support assembly, and HPT air seal sleeve. (2) If engine...

  8. Anastomosis in the absence of a suprahyoid release following circumferential sleeve resection is feasible in differentiated thyroid carcinoma patients with tracheal invasion.

    Science.gov (United States)

    Chen, Wanjun; Zou, Shujuan; Wang, Liang; Wu, Changhua; Wang, Zhiqi; Li, Ke; Zhang, Shuguang

    2017-09-01

    Invasion of the trachea is observed in ~6% of patients with differentiated thyroid carcinoma (DTC), and surgery is accepted as the treatment of choice. However, surgical procedures can be challenging and are associated with various risks. The authors of the present study performed a retrospective study of patients with DTC and tumor invasion of the trachea. Outcomes from patients that received circumferential sleeve resection (CSR) of the trachea followed by anastomosis in the absence of suprahyoid release (n=21; CSR group) and patients that underwent tangential resections [n=103; tangential 'shave' resection (TSR) group) were analyzed. In the CSR group, 4 to 8 tracheal rings were circumferentially resected. All patients underwent end-to-end anastomosis in the absence of suprahyoid release following CSR, and 7 patients developed cancer metastasis following surgery. With the exception of 2 patients that succumbed to disease, the remaining patients in the CSR group survived without cancer recurrence. In the TSR group, all of the patients experienced cancer recurrence within five years post-surgery. A total of 61 patients developed metastases in the three years following surgery, and 71 patients succumbed to cancer metastasis within five years. The survival rate of the CSR group was significantly increased compared with the TSR group. The results of the present study suggest that in DTC patients with defects involving up to 8 tracheal rings, it may be appropriate to perform anastomosis without suprahyoid tissue release as it is associated with a reduced incidence of perioperative morbidity.

  9. Operating room fire prevention: creating an electrosurgical unit fire safety device.

    Science.gov (United States)

    Culp, William C; Kimbrough, Bradly A; Luna, Sarah; Maguddayao, Aris J

    2014-08-01

    To reduce the incidence of surgical fires. Operating room fires represent a potentially life-threatening hazard and are triggered by the electrosurgical unit (ESU) pencil. Carbon dioxide is a fire suppressant and is a routinely used medical gas. We hypothesize that a shroud of protective carbon dioxide covering the tip of the ESU pencil displaces oxygen, thereby preventing fire ignition. Using 3-dimensional modeling techniques, a polymer sleeve was created and attached to an ESU pencil. This sleeve was connected to a carbon dioxide source and directed the gas through multiple precisely angled ports, generating a cone of fire-suppressive carbon dioxide surrounding the active pencil tip. This device was evaluated in a flammability test chamber containing 21%, 50%, and 100% oxygen with sustained ESU activation. The sleeve was tested with and without carbon dioxide (control) until a fuel was ignited or 30 seconds elapsed. Time to ignition was measured by high-speed videography. Fires were ignited with each control trial (15/15 trials). The control group median ± SD ignition time in 21% oxygen was 3.0 ± 2.4 seconds, in 50% oxygen was 0.1 ± 1.8 seconds, and in 100% oxygen was 0.03 ± 0.1 seconds. No fire was observed when the fire safety device was used in all concentrations of oxygen (0/15 trials; P fire ignition was 76% to 100%. A sleeve creating a cone of protective carbon dioxide gas enshrouding the sparks from an ESU pencil effectively prevents fire in a high-flammability model. Clinical application of this device may reduce the incidence of operating room fires.

  10. Robot-assisted bronchoplasty using continuous barbed sutures.

    Science.gov (United States)

    Sarsam, Omar Matthieu; Dunning, Joel; Pochulu, Bruno; Baste, Jean-Marc

    2018-01-01

    We describe in this article our bronchoplastic robot-assisted techniques. This consists of using continuous barbed sutures. Our aim is to show the feasibility and the interest of using robotics and this kind of suture material for complex bronchial procedures. We report four cases in France and the UK, two wedge bronchoplasties and two sleeve bronchoplasties for central pulmonary tumors.

  11. Process for the manufacture of seamless metal-clad fiber-reinforced organic matrix composite structures

    Science.gov (United States)

    Bluck, Raymond M. (Inventor); Bush, Harold G. (Inventor); Johnson, Robert R. (Inventor)

    1991-01-01

    A process for producing seamless metal-clad composite structures includes providing a hollow, metallic inner member and an outer sleeve to surround the inner member and define an inner space therebetween. A plurality of continuous reinforcing fibers is attached to the distal end of the outside diameter of the inner member, and the inner member is then introduced, distal end first, into one end of the outer sleeve. The inner member is then moved, distal end first, into the outer sleeve until the inner member is completely enveloped by the outer sleeve. A liquid matrix material is then injected into the space containing the reinforcing fibers between the inner member and the outer sleeve. Next a pressurized heat transfer medium is passed through the inner member to cure the liquid matrix material. Finally, the wall thickness of both the inner member and the outer sleeve are reduced to desired dimensions by chemical etching, which adjusts the thermal expansion coefficient of the metal-clad composite structure to a desired value.

  12. Nuclear reactor fuel assembly grid

    International Nuclear Information System (INIS)

    Alder, J.L.; Kmonk, S.; Racki, F.R.

    1981-01-01

    A grid for a nuclear reactor fuel assembly which includes intersecting straps arranged to form a structure of egg crate configuration. The cells defined by the intersecting straps are adapted to contain axially extending fuel rods, each of which occupy one cell, while each control rod guide tube or thimble occupies the space of four cells. To effect attachment of each guide thimble to the grid, a short intermediate sleeve is brazed to the strap walls and the guide thimble is then inserted therein and mechanically secured to the sleeve walls. Each sleeve preferably, although not necessarily, is equipped with circumferentially spaced openings useful in adjusting dimples and springs in adjacent cells. To accurately orient each sleeve in position in the grid, the ends of straps extending in one direction project through transversely extending straps and terminate in the wall of the guide sleeve. Other straps positioned at right angles thereto terminate in that portion of the wall of a strap which lies next to a wall of the sleeve

  13. THE IMPACT OF ROAD CONDITIONS ON THE SUSTAINABILITY DECLINE IN THE ROAD TRANSPORT IN THE REPUBLIC OF DAGESTAN

    Directory of Open Access Journals (Sweden)

    E. S. Batmanov

    2016-01-01

    Full Text Available The article touches upon the theoretical and experimental studies of the influence of the various components of road conditions to reduce the stability of the vehicle, which lead to skidding and rollover. The resulting research material will improve traffic safety on the roads of the Republic of Dagestan. We give formulas for calculating the critical speed cornering with cross gradients and sharp change in direction, in which the skid and rollover is not excluded, due to the appearance of additional transverse forces of inertia. It is explained that a significant impact on the stability of the car has a «side pull». We give graphs of the lateral force from the vehicle slip angle of tires and tire tread wear of the impact on the quality of grip at different speeds and the amount of coating roughness obtained experimentally. Effect on the skid and rollover car road surface irregularities is marked. In such traffic conditions, the technical condition of the vehicle and in particular the shock absorbers are essential. The schedule damper effect on driving conditions, obtained experimentally.

  14. Thermoelastic/plastic analysis of waste-container sleeve. II. Influence of large displacements on sleeve loading. Technical memorandum report RSI-0017

    International Nuclear Information System (INIS)

    Pariseau, W.G.

    1975-01-01

    Modification of the thermoelastic/plastic finite element program to account for large displacements possibly associated with the development of an extensive plastic zone about a radioactive waste container emplaced in a typical repository room (SALT-4/T model) has been completed. Comparisons of radial stresses acting on the waste container and borehole wall displacements computed by the modified and conventional analyses techniques reveal little difference between the two sets of results over a 10 year heating period for salt strengths 25 percent of original values. Because no significant differences in results arise even under these exaggerated conditions, the more costly large displacement option need be used only sparingly as an occasional control check on the conventional procedure. As a consequence, economy of computer run time can be maintained without sacrifice of accuracy

  15. Device for encapsulating radioactive materials

    International Nuclear Information System (INIS)

    Suthanthiran, K.

    1994-01-01

    A capsule for encapsulating radioactive material for radiation treatment comprising two or more interfitting sleeves, wherein each sleeve comprises a closed bottom portion having a circumferential wall extending therefrom, and an open end located opposite the bottom portion. The sleeves are constructed to fit over one another to thereby establish an effectively sealed capsule container. 3 figs

  16. Valve-sparing and valve-replacing techniques for aortic root replacement in patients with Marfan syndrome: Analysis of early outcome.

    Science.gov (United States)

    Volguina, Irina V; Miller, D Craig; LeMaire, Scott A; Palmero, Laura C; Wang, Xing Li; Connolly, Heidi M; Sundt, Thoralf M; Bavaria, Joseph E; Dietz, Harry C; Milewicz, Dianna M; Coselli, Joseph S

    2009-05-01

    A prospective, international registry study was initiated to provide contemporary comparative data on short-term clinical outcomes after aortic valve-sparing and aortic valve-replacing root operations in patients with Marfan syndrome. The purpose of this initial report is to describe the study design and to compare early outcomes in the first 151 enrolled patients. We assessed 30-day outcomes in 151 patients who met strict Ghent diagnostic criteria for Marfan syndrome and underwent aortic root replacement with either valve-replacing (n = 46) or valve-sparing techniques (n = 105) at one of 18 participating centers. In the valve replacement group, a mechanical composite valve graft was used in 39 (85%) patients and a bioprosthetic valve in 7 (15%). In the valve-sparing group, David V procedures were performed in 57 (54%) patients, David I in 38 (36%), David IV in 8 (8%), Florida sleeve in 1 (1%), and Yacoub remodeling in 1 (1%). No in-hospital or 30-day deaths occurred. Despite longer crossclamp and cardiopulmonary bypass times in the valve-sparing group, there were no significant between-group differences in postoperative complications. Thirty-day valve-related complications occurred in 2 (4%) patients undergoing valve replacement and in 3 (3%) undergoing valve-sparing procedures (P = .6). The analysis of early outcomes revealed that valve-sparing techniques were the most common approach to root replacement in patients with Marfan syndrome in these centers. The complexity of valve-sparing root replacement did not translate into any demonstrable adverse early outcomes. Subsequent analysis will compare the 3-year durability of these two surgical approaches.

  17. Spent nuclear fuel shipping basket

    International Nuclear Information System (INIS)

    Wells, A.H.

    1990-01-01

    This patent describes a basket for a cask for transporting nuclear fuel elements. It comprises: sleeve members, each of the sleeve members having interior cross-section dimensions for receiving a nuclear fuel assembly such that the assembly is restrained from lateral movement within the sleeve member, apertured disk members, means for axially aligning the apertures in the disk members, and means for maintaining the disk members in fixed spaced relationship to form a disk assembly, comprising an array of disks, the aligned apertures of the disks being adapted to receive the sleeve members and maintain them in fixed spaced relationship

  18. The development of auto-sealing system for field joints of polyethylene coated pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Okano, Yoshihiro [NKK Corp., Tsu, Mie (Japan); Shoji, Norio [NKK Corp., Yokohama (Japan); Namioka, Toshiyuki [Nippon Kokan Koji Corp., Osaka (Japan); Komura, Minoru [Nitto Denko Corp., Fukaya, Saitama (Japan)

    1997-08-01

    The paper describes the development of a system to create high quality, automatic sealing of field joints of polyethylene coated pipelines. The system uses a combination of electrically heated shrink sleeves and a low pressure chamber. The self-heating shrink sleeves include electric wires and heat themselves when connected to electricity. A method was developed to eliminate air trapped between the sleeve and steel pipe by shrinking the sleeves under low pressure. The low pressure condition was automatically and easily attained by using a vacuum chamber. The authors verified that the system produces high quality sealing of field joints.

  19. In vitro mechanical evaluation of a novel pin-sleeve system for external fixation of distal limb fractures in horses: a proof of concept study.

    Science.gov (United States)

    Brianza, Stefano; Brighenti, Vittoria; Boure, Ludovic; Sprenger, Victor; Pearce, Simon; Schwieger, Karsten

    2010-07-01

    To evaluate the efficacy of a novel pin-sleeve cast (PSC) system for external fixation of distal limb fractures in horses and to compare it with the transfixation pin cast (TPC) system. Experimental. One bone substitute each was used for the TPC and PSC systems. The PSC was tested in 4 configurations characterized by different pin preloads. Specimens were loaded in axial compression in the elastic range. Variables compared statistically were: bone substitute axial displacement and axial strain measured above implants with strain gauges. Pin preload was correlated with the variables investigated. Load to failure and a fatigue tests supplemented the investigation. The PSC configuration with the highest pin preload showed a significantly lower axial displacement compared with the TPC. No significant differences were observed between all other PSC configurations and the TPC. All PSC systems had a significant decrease in recorded strain compared with the TPC system. Pin axial preload inversely correlated with axial displacement but had no effect on axial strain. In the failure test, the PSC encountered plastic deformation earlier than the TPC. In the fatigue test, the PSC ran >200,000 cycles. Preliminary in vitro tests showed that the PSC system significantly reduced peri-implant strain while concurrently having comparable axial displacement to the TPC system. The PSC system has the potential to reduce the risk of pin loosening in horses.

  20. Circulating endothelial cells (CECs and E-selectin: Predictors of preeclampsia

    Directory of Open Access Journals (Sweden)

    Ferdous Mehrabian

    2012-01-01

    Full Text Available Background: Circulating endothelial cells (CECs and E-selectin are known as sensitive and specific markers of en-dothelial dysfunction. This study investigated whether CECs and E-selectin are surrogate biomarkers of preeclampsia and if measurement of CECs and E-selectin, early in the third trimester, could be a means of predicting preeclampsia. Methods: In this prospective, descriptive-analytic study, rollover test was performed on 523 pregnant women during 28-30 weeks of gestation. CECs were measured by anti-CD 146-driven immunomagnetic isolation in women with posi-tive rollover test. They were followed up prospectively until delivery without any active intervention. Women with and without preeclampsia were determined. The number of CECs and level of E-selectin were compared in the two studied groups. Results: From the 47 pregnant women with positive rollover test who were selected and followed up, 22 individuals were diagnosed with preeclampsia while the remainder were normotensive. Mean CEC numbers was significantly high-er in preeclamptic women than normal pregnancies (24.7 cells/mL vs. 13 cells/mL. The best cut-off point for CEC numbers was 6.5 with a sensitivity of 78.9% and a specificity of 69.1%. The level of E-selectin was significantly higher in mothers with preeclampsia (p < 0.05. Conclusions: Higher levels of CECs and E-selectin in women with positive rollover test who developed preeclampsia prior to onset of the complication were predictive of preeclampsia. However, larger studies are needed to confirm these findings.

  1. Method and apparatus for extracting tritium and preparing radioactive waste for disposal

    Science.gov (United States)

    Heung, Leung K.

    1994-01-01

    Apparatus for heating an object such as a nuclear target bundle to release and recover hydrogen and contain the disposable residue for disposal. The apparatus comprises an inverted furnace, a sleeve/crucible assembly for holding and enclosing the bundle, conveying equipment for placing the sleeve onto the crucible and loading the bundle into the sleeve/crucible, a lift for raising the enclosed bundle into the furnace, and hydrogen recovery equipment including a trap and strippers, all housed in a containment having negative internal pressure. The crucible/sleeve assembly has an internal volume that is sufficient to enclose and hold the bundle before heating; the crucible's internal volume is sufficient by itself to hold and enclose the bundle's volume after heating. The crucible can then be covered and disposed of; the sleeve, on the other hand, can be reused.

  2. Homopolar machine for reversible energy storage and transfer systems

    Science.gov (United States)

    Stillwagon, Roy E.

    1978-01-01

    A homopolar machine designed to operate as a generator and motor in reversibly storing and transferring energy between the machine and a magnetic load coil for a thermo-nuclear reactor. The machine rotor comprises hollow thin-walled cylinders or sleeves which form the basis of the system by utilizing substantially all of the rotor mass as a conductor thus making it possible to transfer substantially all the rotor kinetic energy electrically to the load coil in a highly economical and efficient manner. The rotor is divided into multiple separate cylinders or sleeves of modular design, connected in series and arranged to rotate in opposite directions but maintain the supply of current in a single direction to the machine terminals. A stator concentrically disposed around the sleeves consists of a hollow cylinder having a number of excitation coils each located radially outward from the ends of adjacent sleeves. Current collected at an end of each sleeve by sleeve slip rings and brushes is transferred through terminals to the magnetic load coil. Thereafter, electrical energy returned from the coil then flows through the machine which causes the sleeves to motor up to the desired speed in preparation for repetition of the cycle. To eliminate drag on the rotor between current pulses, the brush rigging is designed to lift brushes from all slip rings in the machine.

  3. Homopolar machine for reversible energy storage and transfer systems

    International Nuclear Information System (INIS)

    Stillwagon, R.E.

    1981-01-01

    A homopolar machine designed to operate as a generator and motor in reversibly storing and transferring energy between the machine and a magnetic load coil for a thermo-nuclear reactor. The machine rotor comprises hollow thin-walled cylinders or sleeves which form the basis of the system by utilizing substantially all of the rotor mass as a conductor thus making it possible to transfer substantially all the rotor kinetic energy electrically to the load coil in a highly economical and efficient manner. The rotor is divided into multiple separate cylinders or sleeves of modular design, connected in series and arranged to rotate in opposite directions but maintain the supply of current in a single direction to the machine terminals. A stator concentrically disposed around the sleeves consists of a hollow cylinder having a number of excitation coils each located radially outward from the ends of adjacent sleeves. Current collected at an end of each sleeve by sleeve slip rings and brushes is transferred through terminals to the magnetic load coil. Thereafter, electrical energy returned from the coil then flows through the machine which causes the sleeves to motor up to the desired speed in preparation for repetition of the cycle. To eliminate drag on the rotor between current pulses, the brush rigging is designed to lift brushes from all slip rings in the machine

  4. Evolution of subclinical hypothyroidism and its relation with glucose and triglycerides levels in morbidly obese patients after undergoing sleeve gastrectomy as bariatric procedure.

    Science.gov (United States)

    Ruiz-Tovar, Jaime; Boix, Evangelina; Galindo, Isabel; Zubiaga, Lorea; Diez, María; Arroyo, Antonio; Calpena, Rafael

    2014-05-01

    There is an increased prevalence of subclinical hypothyroidism (SCH) in patients with obesity. It is unclear if this biochemical abnormality may be a secondary phenomenon of obesity or a real hypothyroid state. A retrospective study of all the morbidly obese patients undergoing laparoscopic sleeve gastrectomy as bariatric procedure between October 2007 and November 2012 was performed. Weight loss, body mass index (BMI) and excess weight loss, baseline glucose, lipid profiles, and TSH levels were obtained before operation and postoperative determinations at 3, 6, and 12 months after surgery. Sixty patients were included. Prevalence of subclinical hypothyroidism was 16.7% preoperatively, 10% at 3 months, 3.3% at 6 months, and 1.7% at 12 months. A significant correlation could be established between TSH decrease and weight loss at 12 months (Pearson 0.603; p = 0.007). TSH decrease showed a significant correlation with glucose and glycated hemoglobin decrease from 6th month onwards. Referring to lipid profile, an association of TSH decrease with total cholesterol, LDL cholesterol, or HDL cholesterol could not be determined. A significant association between TSH decrease and triglycerides and cardiovascular risk index triglycerides/HDL cholesterol reductions could also be established 12 months after surgery. SCH is usually corrected after bariatric surgery, while there are no significant changes in total or LDL cholesterol. This suggests that, in morbidly obese subjects, SCH is, in most patients, just a consequence of the abnormal fat accumulation and not a real hypothyroid state.

  5. Containment penetration design and analysis by finite element methods

    International Nuclear Information System (INIS)

    Perry, R.F.; Rigamonti, G.; Dainora, J.

    1975-01-01

    Containment penetration designs which provide complete support to process piping containing high pressure and high temperature fluids and which do not employ cooling coils, require special provisions to sustain loadings associated with normal/abnormal conditions and to limit maximum temperature transmitted to the containment concrete wall. In order to accommodate piping imposed loads and fluid temperatures within code and regulatory limitations, the containment penetration designs require careful analysis of two critical regions: the portion of the penetration sleeve which is exposed to containment ambient conditions and the portion of the penetration which connects the sleeve to process piping (flued head). The length and thickness of the sleeve must be designed to provide maximum heat dissipation to the atmosphere and minimum heat conduction through the sleeve to meet concrete temperature limitations. The sleeve must have the capability to transmit the postulated piping loads to concrete embedments in the containment shell. The penetration flued head design must be strong enough to transfer high mechanical loads and be flexible enough to accommodate the thermal stresses generated by the high temperature fluid. Analytical models using finite element representations of process piping, penetration flued head, and exposed sleeve were employed to investigate the penetration assembly design. By application of flexible multi-step analyses, different penetration configurations were evaluated to determine the effects of key design parameters. Among the parameters studied were flued head profiles, flued head angles with the process piping, sleeve length and wall thickness. Special designs employing fins welded to the sleeve to lower the temperature at the concrete wall interface were investigated and fin geometry effects reported

  6. Gesture-Based Robot Control with Variable Autonomy from the JPL Biosleeve

    Science.gov (United States)

    Wolf, Michael T.; Assad, Christopher; Vernacchia, Matthew T.; Fromm, Joshua; Jethani, Henna L.

    2013-01-01

    This paper presents a new gesture-based human interface for natural robot control. Detailed activity of the user's hand and arm is acquired via a novel device, called the BioSleeve, which packages dry-contact surface electromyography (EMG) and an inertial measurement unit (IMU) into a sleeve worn on the forearm. The BioSleeve's accompanying algorithms can reliably decode as many as sixteen discrete hand gestures and estimate the continuous orientation of the forearm. These gestures and positions are mapped to robot commands that, to varying degrees, integrate with the robot's perception of its environment and its ability to complete tasks autonomously. This flexible approach enables, for example, supervisory point-to-goal commands, virtual joystick for guarded teleoperation, and high degree of freedom mimicked manipulation, all from a single device. The BioSleeve is meant for portable field use; unlike other gesture recognition systems, use of the BioSleeve for robot control is invariant to lighting conditions, occlusions, and the human-robot spatial relationship and does not encumber the user's hands. The BioSleeve control approach has been implemented on three robot types, and we present proof-of-principle demonstrations with mobile ground robots, manipulation robots, and prosthetic hands.

  7. Fabrication process of expanded cooling jackets

    International Nuclear Information System (INIS)

    Weber, C.M.

    1980-01-01

    The present invention concerns the fabrication process of heat exchangers and in particular, the fabrication and assembly process of cooling jackets of the system driving the control rods used in nuclear reactors. The cooling jackets are assembled for cooling the stator of a tubular motor displacing the control rods. The fabrication and assembling of the cooling jacket is made up by the following operations: - a sleeve has an inner fluid inlet and outlet ways, - an external socket is fitted to the sleeve, - on the external socket a continuous welding is realized, which join the socket to the sleeve, and define a serie of parallel welded turns, - a pressure is established between the sleeve and the socket by a fluid through the outlet or inlet ways of the sleeve. When the other way is sealed up, the socket expands between the welded turns, and the fluid can pass through the jacket [fr

  8. Radioactive source manipulator and stowage device

    International Nuclear Information System (INIS)

    Burton, C.

    1980-01-01

    A description is given of a radioactive source manipulator and stowage device comprising: a cylindrical body; a transversely disposed socket formed near one end of said cylindrical body for receiving a radioactive source; a cylindrical sleeve rotatably mounted on said cylindrical body; and an aperture formed in the wall of said sleeve whereby rotation of said sleeve to axially align said aperture with said socket will permit a radioactive source to be inserted into and removed from said socket and rotation of said sleeve to move said aperture out of alignment with said socket when the socket contains a radioactive source readies the device for manipulation and stowage

  9. Cryogenic support member

    International Nuclear Information System (INIS)

    Niemann, R.C.; Gonczy, J.D.; Nicol, T.H.

    1987-01-01

    A cryogenic support member is described for restraining a cryogenic system comprising; a rod having a depression at a first end. The rod is made of non-metallic material. The non-metallic material has an effectively low thermal conductivity; a metallic plug; and a metallic sleeve. The plug and the sleeve are shrink-fitted to the depression in the rod and assembled thereto such that the plug is disposed inside the depression of the rod. The sleeve is disposed over the depression in the rod and the rod is clamped therebetween. The shrink-fit clamping the rod is generated between the metallic plug and the metallic sleeve

  10. Control rod guide tube assemblies

    International Nuclear Information System (INIS)

    Jabsen, F.S.

    1979-01-01

    A nuclear fuel assembly including sleeves telescoped over end portions of control rod guide tubes which bear against internal shoulders of the sleeves. Upper ends of the sleeves protrude beyond a control rod guide tube spider and are locked in place by means of a resilient cellular lattice or lock that is seated in mating grooves in the outer surfaces of the sleeves. A grapple is provided for disengaging the entire lock structure spider and associated washers, springs and a grill from the end of the fuel assembly in order to enable these components to be removed and subsequently replaced on the fuel assembly after inspection and repair. (UK)

  11. Nuclear fuel elements

    International Nuclear Information System (INIS)

    Ainsworth, K.F.

    1979-01-01

    A nuclear fuel element is described having a cluster of nuclear fuel pins supported in parallel, spaced apart relationship by transverse cellular braces within coaxial, inner and outer sleeves, the inner sleeve being in at least two separate axial lengths, each of the transverse braces having a peripheral portion which is clamped peripherally between the ends of the axial lengths of the inner sleeve. (author)

  12. ANALYSIS OF FOOD TOLERANCE IN PATIENTS SUBMITTED TO BARIATRIC SURGERY USING THE QUESTIONNAIRE QUALITY OF ALIMENTATION.

    Science.gov (United States)

    Stumpf, Matheo Augusto Morandi; Rodrigues, Marcos Ricardo da Silva; Kluthcovsky, Ana Claudia Garabeli Cavalli; Travalini, Fabiana; Milléo, Fábio Quirillo

    2015-01-01

    Due to the increased prevalence of obesity in many countries, the number of bariatric surgeries is increasing. They are considered the most effective treatment for obesity. In the postoperative there may be difficulties with the quality of alimentation, tolerance to various types of food, as well as vomiting and regurgitation. Few surveys are available to assess these difficulties in the postoperative. To perform a systematic literature review about food tolerance in patients undergoing bariatric surgery using the questionnaire "Quality of Alimentation", and compare the results between different techniques. A descriptive-exploratory study where the portals Medline and Scielo were used. The following headings were used in english, spanish and portuguese: quality of alimentation, bariatric surgery and food tolerance. A total of 88 references were found, 14 used the questionnaire "Quality of Alimentation" and were selected. In total, 2745 patients were interviewed of which 371 underwent to gastric banding, 1006 to sleeve gastrectomy, 1113 to Roux-en-Y gastric bypass, 14 to biliopancreatic diversion associated with duodenal switch, 83 were non-operated obese, and 158 non-obese patients. The questionnaire showed good acceptability. The biliopancreatic diversion with duodenal switch had the best food tolerance in the postoperative when compared to other techniques, but it was evaluated in a single article with a small sample. The longer the time after the operation, the better is the food tolerance. Comparing the sleeve gastrectomy and the Roux-en-Y gastric bypass, there are still controversial results in the literature. The gastric banding had the worst score of food tolerance among all the techniques evaluated. The questionnaire is easy and fast to assess the food tolerance in patients after bariatric surgery. Biliopancreatic diversion with duodenal switch had the best food tolerance in the postoperative when compared to sleeve gastrectomy and the Roux-en-Y gastric

  13. Implementing MRI-based target delineation for cervical cancer treatment within a rapid workflow environment for image-guided brachytherapy: A practical approach for centers without in-room MRI.

    Science.gov (United States)

    Trifiletti, Daniel M; Libby, Bruce; Feuerlein, Sebastian; Kim, Taeho; Garda, Allison; Watkins, W Tyler; Erickson, Sarah; Ornan, Afshan; Showalter, Timothy N

    2015-01-01

    Magnetic resonance imaging (MRI)-based intracavitary brachytherapy offers several advantages over computed tomography (CT)-based brachytherapy, but many centers are unable to offer it at the time of brachytherapy because of logistic and/or financial considerations. We have implemented a method of integrating MRI into a CT-guided, high-dose-rate intracavitary brachytherapy workflow in clinics that do not have immediately available MRI capability. At our institution, patients receiving high-dose-rate intracavitary brachytherapy as a component of the definitive treatment of cervical cancer have a Smit sleeve placed during the first brachytherapy fraction in a dedicated suite with in-room CT-on-rails. After the first fraction of brachytherapy, an MRI is obtained with the Smit sleeve, but no applicator, in place. For each subsequent fraction, CT scans are coregistered to the MRI scan by the Smit sleeve. The gross target volume is defined by MRI and overlaid on the CT images for each brachytherapy treatment for dose optimization. This MRI-integrated workflow adds workflow is a feasible compromise to preserve an efficient workflow while integrating MRI target delineation, and it provides many of the advantages of both MRI- and CT-based brachytherapy. The future collection and analysis of clinical data will serve to compare the proposed approach to non-MRI containing techniques. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  14. A Novel Technique to Prevent Effluent Spillage During Percutaneous Cystolithotripsy

    Directory of Open Access Journals (Sweden)

    Shenoy SP

    2015-07-01

    Full Text Available Our objective was to design an efficient system for collection of refluxing irrigant during performance of percutaneous cystolithotripsy (PCL to avoid the messy spillage and its undesirable consequences on the patient, the operating team and the operating room environment. A closed drainage system using a long sleeve surgical glove, 10 millimeter laparoscopic trocar, 30 french Amplatz sheath, Y-tubing and linen thread was designed for performing PCL without disconnection during the procedure. While the refluxing effluent was efficiently drained, minimizing spillage, the calculus fragments were collected in a distensible receptacle adjacent to the Amplatz sheath. Three procedures were performed over a year on males with large bladder calculi. The system designed by us was easy to set up, lent itself to easy unhindered performance of the procedure, and spillage of effluent was minimized.

  15. Remodeling of the residual gastric mucosa after roux-en-y gastric bypass or vertical sleeve gastrectomy in diet-induced obese rats.

    Directory of Open Access Journals (Sweden)

    Konstantinos Arapis

    Full Text Available Whereas the remodeling of intestinal mucosa after bariatric surgeries has been the matter of numerous studies to our knowledge, very few reported on the remodeling of the residual gastric mucosa. In this study, we analyzed remodeling of gastric mucosa after Roux-en-Y gastric bypass (RYGB and vertical sleeve gastrectomy (VSG in rats. Diet-induced obese rats were subjected to RYGB, VSG or sham surgical procedures. All animals were assessed for food intake, body-weight, fasting blood, metabolites and hormones profiling, as well as insulin and glucose tolerance tests before and up to 5 weeks post-surgery. Remodeling of gastric tissues was analyzed by routine histology and immunohistochemistry studies, and qRT-PCR analyses of ghrelin and gastrin mRNA levels. In obese rats with impaired glucose tolerance, VSG and RYGB caused substantial weight loss and rats greatly improved their oral glucose tolerance. The remaining gastric mucosa after VSG and gastric pouch (GP after RYGB revealed a hyperplasia of the mucous neck cells that displayed a strong immunoreactivity for parietal cell H+/K+-ATPase. Ghrelin mRNA levels were reduced by 2-fold in remaining fundic mucosa after VSG and 10-fold in GP after RYGB. In the antrum, gastrin mRNA levels were reduced after VSG in line with the reduced number of gastrin positive cells. This study reports novel and important observations dealing with the remaining gastric mucosa after RYGB and VSG. The data demonstrate, for the first time, a hyperplasia of the mucous neck cells, a transit cell population of the stomach bearing differentiating capacities into zymogenic and peptic cells.

  16. Morphofunctional Changes After Sleeve Gastrectomy and Very Low Calorie Diet in an Animal Model of Non-Alcoholic Fatty Liver Disease.

    Science.gov (United States)

    Talavera-Urquijo, Eider; Rodríguez-Navarro, Sarai; Beisani, Marc; Salcedo-Allende, Maria Teresa; Chakkur, Aisha; Arús-Avilés, Marc; Cremades, Manel; Augustin, Salvador; Martell, María; Balibrea, José M

    2018-01-01

    Non-alcoholic fatty liver disease (NAFLD) is the most prevalent chronic liver disease and is found in 70% of obese people. The evidence available to date suggests that bariatric surgery could be an effective treatment by reducing weight and also by improving metabolic complications in the long term. This work aimed to compare, in a diet-induced NAFLD animal model, the effect of both sleeve gastrectomy (SG) and very-low calorie diet (VLCD). Thirty-five Wistar rats were divided into control rats (n = 7) and obese rats fed a high-fat diet (HFD). After 10 weeks, the obese rats were subdivided into four groups: HFD (n = 7), VLCD (n = 7), and rats submitted to either a sham operation (n = 7) or SG (n = 7). Both liver tissue and blood samples were processed to evaluate steatosis and NASH changes in histology (Oil Red, Sirius Red and H&E); presence of endothelial damage (CD31, Moesin/p-Moesin, Akt/p-Akt, eNOS/p-eNOS), oxidative stress (iNOS) and fibrosis (αSMA, Col1, PDGF, VEGF) proteins in liver tissue; and inflammatory (IL6, IL10, MCP-1, IL17α, TNFα), liver biochemical function, and hormonal (leptin, ghrelin, visfatin and insulin) alterations in plasma. Both VLCD and SG improved histology, but only SG induced a significant weight loss, improved endothelial damage, and a decreased cardiovascular risk by reducing insulin resistance (IR), leptin, total cholesterol, and triglyceride levels. There were no relevant variations in the inflammatory and fibrosis markers. Our study suggests a slight superiority of SG over VLCD by improving not only the histology but also the IR and cardiovascular risk markers related to NAFLD.

  17. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    J. Spalding

    2011-01-01

    All the HCAL calorimeters are ready for data-taking in 2011 and participated fully in the cosmic running and initial beam operations in the last few weeks. Several improvements were made during the winter technical stop, including replacement of the light-guide sleeves in HF, improvements to the low voltage power connections, and separation of HF from HB and HE in the DAQ partitions. During the 2010 running a form of anomalous noise in the HF was identified as being caused by scintillation when charged particles pass through a portion of the air light-guide sleeve. This portion was constructed from a non-conductive mirror-like material called “HEM”. To suppress these anomalous signals, during the recent winter technical stop all sleeves in the detector were replaced with sleeves made of Tyvek. The detector has been recommissioned with all channels fully operational. Recalibration of the detector will be required due to the differing reflectivity of the new sleeves compared with the HEM sl...

  18. Accuracy of thick-walled hollows during piercing on three-high mill

    International Nuclear Information System (INIS)

    Potapov, I.N.; Romantsev, B.A.; Shamanaev, V.I.; Popov, V.A.; Kharitonov, E.A.

    1975-01-01

    The results of investigations are presented concerning the accuracy of geometrical dimensions of thick-walled sleeves produced by piercing on a 100-ton trio screw rolling mill MISiS with three schemes of fixing and centering the rod. The use of a spherical thrust journal for the rod and of a long centering bushing makes it possible to diminish the non-uniformity of the wall thickness of the sleeves by 30-50%. It is established that thick-walled sleeves with accurate geometrical dimensions (nonuniformity of the wall thickness being less than 10%) can be produced if the system sleeve - mandrel - rod is highly rigid and the rod has a two- or three-fold stability margin over the length equal to that of the sleeve being pierced. The process of piercing is expedient to be carried out with increased angles of feed (14-16 deg). Blanks have been made from steel 12Kh1MF

  19. WELDING TORCH

    Science.gov (United States)

    Correy, T.B.

    1961-10-01

    A welding torch into which water and inert gas are piped separately for cooling and for providing a suitable gaseous atmosphere is described. A welding electrode is clamped in the torch by a removable collet sleeve and a removable collet head. Replacement of the sleeve and head with larger or smaller sleeve and head permits a larger or smaller welding electrode to be substituted on the torch. (AEC)

  20. Experimental study on heat transfer characteristic of T-junction in cooling system of PWR

    International Nuclear Information System (INIS)

    Wang Haijun; Lu Donghua; Luo Yushan; Chen Tingkuan

    2002-01-01

    The local near wall fluid temperature and heat transfer coefficient distribution in three different areas were measured for T-junction with and without thermal sleeve where jet injected vertically down to the main flow. Flow with velocity ratio between 0.01 and 1.5 were measured. The diameter ratio of jet pipe to main pipe is 0.16. It was found at that downstream of the jet, the thermal sleeve has little effect on heat transfer. At the inlet of the jet and inside the jet tube, the thermal sleeve distinctly affect heat transfer coefficient and near wall fluid temperature. The thermal sleeve's effect is more marked when the velocity ratio becomes larger

  1. Control rod guide tube assembly

    International Nuclear Information System (INIS)

    Jabsen, F.S.

    1982-01-01

    An improved fuel assembly is described as consisting of a sleeve that engages one end of a control rod guide tube essentially fixing the guide tube to one of the fuel assembly end structures. The end of the sleeve protrudes above the surface of the end fitting. The outer surface of the sleeve has a peripheral groove that engages the resilient sides of a cellular grid or lattice shaped lock. This lock fixes the sleeve in position between the various elements that comprise the end fitting, thereby eliminating a profusion of costly and potentially troublesome nuts, threaded studs and the like that are frequently employed in the fuel assemblies that are presently in use

  2. Current Techniques of Teaching and Learning in Bariatric Surgical Procedures: A Systematic Review.

    Science.gov (United States)

    Kaijser, Mirjam; van Ramshorst, Gabrielle; van Wagensveld, Bart; Pierie, Jean-Pierre

    The gastric sleeve resection and gastric bypass are the 2 most commonly performed bariatric procedures. This article provides an overview of current teaching and learning methods of those techniques in resident and fellow training. A database search was performed on Pubmed, Embase, and the Education Resources Information Center (ERIC) to identify the methods used to provide training in bariatric surgery worldwide. After exclusion based on titles and abstracts, full texts of the selected articles were assessed. Included articles were reviewed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. In total, 2442 titles were identified and 14 full text articles met inclusion criteria. Four publications described an ex vivo training course, and 6 focused on at least 1 step of the gastric bypass procedure. Two randomized controlled trials (RCT) provided high-quality evidence on training aspects. Surgical coaching caused significant improvement of Bariatric Objective Structured Assessment of Technical Skills (BOSATS) scores (3.60 vs. 3.90, p = 0.017) and reduction of technical errors (18 vs. 10, p = 0.003). A preoperative warm-up increased global rating scales (GRS) scores on depth perception (p = 0.02), bimanual dexterity (p = 0.01), and efficiency of movements (p = 0.03). Stepwise education, surgical coaching, warming up, Internet-based knowledge modules, and ex vivo training courses are effective in relation to bariatric surgical training of residents and fellows, possibly shortening their learning curves. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  3. A case of severe anorexia, excessive weight loss and high peptide YY levels after sleeve gastrectomy.

    Science.gov (United States)

    Pucci, Andrea; Cheung, Wui Hang; Jones, Jenny; Manning, Sean; Kingett, Helen; Adamo, Marco; Elkalaawy, Mohamed; Jenkinson, Andrew; Finer, Nicholas; Doyle, Jacqueline; Hashemi, Majid; Batterham, Rachel L

    2015-01-01

    Sleeve gastrectomy (SG) is the second most commonly performed bariatric procedure worldwide. Altered circulating gut hormones have been suggested to contribute post-operatively to appetite suppression, decreased caloric intake and weight reduction. In the present study, we report a 22-year-old woman who underwent laparoscopic SG for obesity (BMI 46 kg/m(2)). Post-operatively, she reported marked appetite reduction, which resulted in excessive weight loss (1-year post-SG: BMI 22 kg/m(2), weight loss 52%, >99th centile of 1-year percentage of weight loss from 453 SG patients). Gastrointestinal (GI) imaging, GI physiology/motility studies and endoscopy revealed no anatomical cause for her symptoms, and psychological assessments excluded an eating disorder. Despite nutritional supplements and anti-emetics, her weight loss continued (BMI 19 kg/m(2)), and she required nasogastric feeding. A random gut hormone assessment revealed high plasma peptide YY (PYY) levels. She underwent a 3 h meal study following an overnight fast to assess her subjective appetite and circulating gut hormone levels. Her fasted nausea scores were high, with low hunger, and these worsened with nutrient ingestion. Compared to ten other post-SG female patients, her fasted circulating PYY and nutrient-stimulated PYY and active glucagon-like peptide 1 (GLP1) levels were markedly elevated. Octreotide treatment was associated with suppressed circulating PYY and GLP1 levels, increased appetite, increased caloric intake and weight gain (BMI 22 kg/m(2) after 6 months). The present case highlights the value of measuring gut hormones in patients following bariatric surgery who present with anorexia and excessive weight loss and suggests that octreotide treatment can produce symptomatic relief and weight regain in this setting. Roux-en-Y gastric bypass and SG produce marked sustained weight reduction. However, there is a marked individual variability in this reduction, and post-operative weight loss

  4. Research on Strategies and Methods Suppressing Permanent Magnet Demagnetization in Permanent Magnet Synchronous Motors Based on a Multi-Physical Field and Rotor Multi-Topology Structure

    Directory of Open Access Journals (Sweden)

    Lin Li

    2017-12-01

    Full Text Available In this paper, a permanent magnet synchronous motor (PMSM with sleeves on the rotor outer surface is investigated. The purpose of sleeves is to fix the permanent magnets and protect them from being destroyed by the large centrifugal force. However, the sleeve material characteristics have a great influence on the PMSM, and therewith, most of the rotor eddy-current losses are generated in the rotor sleeve, which could increase the device temperature and even cause thermal demagnetization of the magnets. Thus, a sleeve scheme design with low eddy-current losses is necessary, and a method suppressing the local temperature peak of permanent magnets is presented. The 3-D electromagnetic finite element model of a 12.5 kW, 2000 r/min PMSM with a segmented sleeve is established, and the electromagnetic field is calculated by using the finite element method. The results show the effectiveness of the presented method in reducing the eddy current losses in the rotor. Using the thermal method, it can be found that the maximum temperature position and zone of permanent magnet will change. Thus, some strategies are comparatively analyzed in order to obtain the change rule of the position and zone. The obtained conclusions may provide a useful reference for the design and research of PMSMs.

  5. Pulsed eddy currents: principle and applications

    International Nuclear Information System (INIS)

    Bernard, A.; Coutanceau, N.

    1993-04-01

    Eddy currents are widely used as a non destructive testing technique specially for heat exchanger testing. The specificities of pulsed eddy current testing are analyzed in terms of probe design and signal processing. The specific applications are detailed. They are divided in two parts. First part, deals with the two main applications of the high peak energy supplied to the probe. One concerns the design of focused probes used for the detection of small defects in irradiated fuel rods. The other concerns the saturation of ferromagnetic materials in order to test the full thickness of the exchanger tubes. Second part, deals with applications of the wide and low frequency spectrum generated by the pulse source. It enables the testing of thick materials, and the detection of sub-surface defects. It has been tested on austenitic steel (nuclear pressure vessel nozzle), multilayered structures of aluminium alloys (aeronautics) and sleeved structures (nuclear pressure vessel head penetrations through thermal sleeves)

  6. Results from impression packer technique for location of fissures in boreholes in white chalk, Mors, Denmark

    International Nuclear Information System (INIS)

    Andersen, L.J.; Byrne, L.; Frykman, P.

    1981-01-01

    In connection with site investigations to evaluate the possibility of geological disposal of radioactive waste in a salt dome a Hydrogeological Programme was carried out. A number of bore holes were drilled to depths of 550 m. Geological and hydrogeological investigations were performed. The hydrogeological tests were carried out as packer tests, bottomhole tests using one packer, or straddle-packer test using two packers. In connection with these tests a rubber sleeve was installed over the packer and sidewall impressions of the hole were taken. Irregularities such as faults and fissures and possibly solution features were localized. The paper describes the method, procedure, equipment and the results achieved

  7. Effects of sleeve gastrectomy and ileal transposition, alone and in combination, on food intake, body weight, gut hormones, and glucose metabolism in rats.

    Science.gov (United States)

    Nausheen, S; Shah, I H; Pezeshki, A; Sigalet, D L; Chelikani, P K

    2013-08-15

    Bariatric surgeries are hypothesized to produce weight loss and improve diabetes control by multiple mechanisms including gastric restriction and lower gut stimulation; the relative importance of these mechanisms remains poorly understood. We compared the effects of a typical foregut procedure, sleeve gastrectomy, (SG) with a primarily hindgut surgery, ileal transposition (IT), alone and together (SGIT), or sham manipulations, on food intake, body weight, gut hormones, glucose tolerance, and key markers of glucose homeostasis in peripheral tissues of adult male Sprague-Dawley rats (450-550 g, n = 7-9/group). SG, IT, and SGIT surgeries produced transient reduction in food intake and weight gain; the effects of SG and IT on intake and body weight were nonadditive. SG, IT, and SGIT surgeries resulted in increased tissue expression and plasma concentrations of the lower gut hormones glucagon-like peptide-1 and peptide YY and decreased plasma glucose-dependent insulinotropic peptide, insulin, and leptin concentrations. Despite transient effects on intake and weight gain, the SG, IT, and SGIT surgeries produced a significant improvement in glucose tolerance. In support of glycemic improvements, the protein abundance of key markers of glucose metabolism (e.g., GLUT4, PKA, IRS-1) in muscle and adipose tissue were increased, whereas the expression of key gluconeogenic enzyme in liver (G-6-Pase) were decreased following the surgeries. Therefore, our data suggest that enhanced lower gut stimulation following SG, IT, and SGIT surgeries leads to transient reduction in food intake and weight gain together with enhanced secretion of lower gut hormones and improved glucose clearance by peripheral tissues.

  8. Conversion of Sleeve Gastrectomy to Roux-en-Y Gastric Bypass is Effective for Gastro-Oesophageal Reflux Disease but not for Further Weight Loss.

    Science.gov (United States)

    Parmar, Chetan D; Mahawar, Kamal K; Boyle, Maureen; Schroeder, Norbert; Balupuri, Shlok; Small, Peter K

    2017-07-01

    Inadequate weight loss (IWL)/weight regain (WR) and gastro-esophageal reflux disease (GERD), unresponsive to medical management, are two most common indications for conversion of sleeve gastrectomy (SG) to Roux-en-Y gastric bypass (RYGB). This study reports detailed outcomes of conversion of SG to RYGB for these two indications separately. We interrogated our prospectively maintained database to identify patients who underwent a conversion of their SG to RYGB in our unit. Outcomes in patients converted for IWL/WR and those converted for GERD were evaluated separately. We carried out 22 SG to RYGB in our unit between Aug 2012 and April 2015 with a mean follow-up of 16 months. Indication for conversion was GERD in 10/22 (45.5%) patients and IWL/WR in 11/22 (50.0%) patients. Patients undergoing conversion for GERD were significantly lighter (BMI 30.5) than those converted for IWL/WR (BMI 43.3) at the time of conversion. The conversion was very effective for GERD with 100% patients reporting improvement in symptoms, and 80% patients were able to stop their antacid medications. IWL/WR group achieved a further BMI drop of 2.5 points 2 years after surgery (final BMI 40.8) in comparison with 2.0 points BMI drop achieved by the GERD group (final BMI 28.5). This study demonstrates that conversion of SG to RYGB is effective for GERD symptoms but not for further weight loss, which was modest in both groups. Future studies need to examine the best revisional procedure for IWL/WR after SG.

  9. Laparoscopic Sleeve Gastrectomy for Mildly Obese Patients (Body Mass Index of 30 <35 kg/m2: Operative Outcome and Short-Term Results

    Directory of Open Access Journals (Sweden)

    Roger Noun

    2012-01-01

    Full Text Available Background. Data concerning laparoscopic sleeve gastrectomy (LSG in mild obesity are under investigation. Aim/Objective. May 2010 to May 2012, 122 consecutive patients with preoperative body mass index (BMI of 33±2.5 kg/m2 (range 30–34.9 undergoing LSG were studied. Mean age was 33±10 years (range 15–60, and 105 (86% were women. Mean preoperative weight was 91±9.7 kg (range 66–121, and preoperative excess weight was 30±6.7 kg (range 19–43. Comorbidities were detected in 44 (36% patients. Results. Mean operative time was 58±15 min (range 40–95, and postoperative stay was 1.8±0.19 days (range 1.5–3. There were no admissions to intensive care unit and no deaths within 30 days of surgery. The rates of leaks and strictures were 0%, and of hemorrhage 1.6%. At 12 months, BMI decreased to 24.7±2, and the percentage of excess weight loss (% EWL reached 76.5%. None of the patients had a BMI below 20 kg/m2. Comorbidities resolved in 70.5% or improved in 29.5%. Patient satisfaction scoring (1–5 at least 1 year after was 4.6±0.8 for body image and 4.4±0.6 for food tolerance. Conclusion. LSG for mildly obese patients has proved to be technically relatively easy, safe, and benefic in the short term.

  10. Demountable fuel assembly for light water cooled nuclear reactor

    International Nuclear Information System (INIS)

    Petit, B.

    1990-01-01

    The guide tube is fixed in an adaptor plate by a blocking sleeve. The blocking sleeve has a part for expanding the tube and a fixing ring in the adaptor plate. The fixing ring has cylindrical sections separated by slots disposed following the direction to generate the ring. The cylindrical sections present deformations to the interior of the cavity of a radial direction compared to the hole through the adaptor plate to assure the fixing of the blocking sleeve. The cylindrical sections of the fixing ring can be bent over towards the inside to disengage the deformations from the cavities before extraction of the blocking sleeve to allow demounting of the connection between the guide tube and the adaptor plate [fr

  11. Vehicle rollover sensor test modeling

    NARCIS (Netherlands)

    McCoy, R.W.; Chou, C.C.; Velde, R. van de; Twisk, D.; Schie, C. van

    2007-01-01

    A computational model of a mid-size sport utility vehicle was developed using MADYMO. The model includes a detailed description of the suspension system and tire characteristics that incorporated the Delft-Tyre magic formula description. The model was correlated by simulating a vehicle suspension

  12. Math-Based Simulation Tools and Methods

    National Research Council Canada - National Science Library

    Arepally, Sudhakar

    2007-01-01

    ...: HMMWV 30-mph Rollover Test, Soldier Gear Effects, Occupant Performance in Blast Effects, Anthropomorphic Test Device, Human Models, Rigid Body Modeling, Finite Element Methods, Injury Criteria...

  13. Process and device for replacing heater in PWR pressurizer

    International Nuclear Information System (INIS)

    Gente, D.; Giron, M.

    1990-01-01

    To assure the tight fixation of replacing heater on a pressurizer penetration sleeve, a gas metal-arc welding single pass is executed. A tubular shaft is fixed over end of heater projecting from penetration sleeve. Over shaft is fixed tubular support for the torch which can rotate about axis of support axis heater. Welding torch and welding wire feeder roll are rotated in synchronisation by appropriate motors. Weld is made in single pass round periphery of heater and penetration sleeve [fr

  14. [Prevention, diagnosis and treatment of perioperative complications of bariatric and metabolic surgery].

    Science.gov (United States)

    Wu, Haifu; Zhong, Ming; Zhou, Di; Shi, Chenye; Jiao, Heng; Wu, Wei; Chang, Xinxia; Cang, Jing; Bian, Hua

    2017-04-25

    Surgical operation in treating obesity and type 2 diabetes is popularizing rapidly in China. Correct prevention and recognition of perioperation-related operative complications is the premise of ensuring surgical safety. Familiar complications of the operation include deep venous thrombosis, pulmonary artery embolism, anastomotic bleeding, anastomotic fistula and marginal ulcer. The prevention of deep venous thrombosis is better than treatment. The concrete measures contain physical prophylaxis (graduated compression stocking and intermittent pneumatic compression leg sleeves) and drug prophylaxis (unfractionated heparin and low molecular heparin), and the treatment is mainly thrombolysis or operative thrombectomy. The treatment of pulmonary artery embolism includes remittance of pulmonary arterial hypertension, anticoagulation, thrombolysis, operative thrombectomy, interventional therapy and extracorporeal membrane oxygenation (ECMO). Hemorrhage is a rarely occurred but relatively serious complication after bariatric surgery. The primary cause of anastomotic bleeding after laparoscopic gastric bypass is incomplete hemostasis or weak laparoscopic repair. The common bleeding site in laparoscopic sleeve gastrectomy is gastric stump and close to partes pylorica, and the bleeding may be induced by malformation and weak repair technique. Patients with hemodynamic instability caused by active bleeding or excessive bleeding should timely received surgical treatment. Anastomotic fistula in gastric bypass can be divided into gastrointestinal anastomotic fistula and jejunum-jejunum anastomotic fistula. The treatment of postoperative anastomotic fistula should vary with each individual, and conservative treatment or operative treatment should be adopted. Anastomotic stenosis is mainly related to the operative techniques. Stenosis after sleeve gastrectomy often occurs in gastric angle, and the treatment methods include balloon dilatation and stent implantation, and surgical

  15. Development of β particle hemorrhoids applicator

    International Nuclear Information System (INIS)

    Cai Shanyu; Liu Yunsheng; Zhang Pinyuan; Teng Kezhi; Gu Zeliang; Li Zhi

    2012-01-01

    A brachytherapy instrument, called β particle hemorrhoid therapeutic instrument or β particle hemorrhoid applicator was developed. It is mainly composed of radiator, locator, lifter, shield sleeve and controller. It can be used to treat internal piles, external piles, combined piles, anal fissure, anal sinusitis, etc. Preliminary clinical tests indicate that the advantages of β particle intracavitary radiotherapy are safe, effective, convenient, painless and non-invasive for curing hemorrhoids comparing with other techniques. (authors)

  16. Advanced Developement of Leishmania Tropical Skin Test Antigen

    Science.gov (United States)

    2011-09-01

    adherence to proper procedures and aseptic technique. At the conclusion of the filtration process, TSA/ Lecithin /Polysorbate-80 touch plates are used to... Lecithin /Polysorbate-80 touch plates are used to sample the sleeves and gloves of dedicated operators. The plates arc incubated for seven days at... Therapy , Dose and Mode of Administration, Batch Number: i See above. Criteria for Evaluation: ,Safety: The safety ofLtSTA was based on the absence

  17. PWR integral tie plate and locking mechanism

    International Nuclear Information System (INIS)

    Flora, B.S.; Osborne, J.L.

    1980-01-01

    A locking mechanism for securing an upper tie plate to the tie rods of a nuclear fuel bundle is described. The mechanism includes an upper tie plate assembly and locking sleeves fixed to the ends of the tie rods. The tie plate is part of the upper tie plate assembly and is secured to the fuel bundle by securing the entire upper tie plate assembly to the locking sleeves fixed to the tie rods. The assembly includes, in addition to the tie plate, locking nuts for engaging the locking sleeves, retaining sleeves to operably connect the locking nuts to the assembly, a spring biased reaction plate to restrain the locking nuts in the locked position and a means to facilitate the removal of the entire assembly as a unit from the fuel bundle

  18. Enhancing roll stability of heavy vehicle by LQR active anti-roll bar control using electronic servo-valve hydraulic actuators

    Science.gov (United States)

    Vu, Van Tan; Sename, Olivier; Dugard, Luc; Gaspar, Peter

    2017-09-01

    Rollover of heavy vehicle is an important road safety problem world-wide. Although rollovers are relatively rare events, they are usually deadly accidents when they occur. The roll stability loss is the main cause of rollover accidents in which heavy vehicles are involved. In order to improve the roll stability, most of modern heavy vehicles are equipped with passive anti-roll bars to reduce roll motion during cornering or riding on uneven roads. However these may be not sufficient to overcome critical situations. This paper introduces the active anti-roll bars made of four electronic servo-valve hydraulic actuators, which are modelled and integrated in a yaw-roll model of a single unit heavy vehicle. The control signal is the current entering the electronic servo-valve and the output is the force generated by the hydraulic actuator. The active control design is achieved solving a linear optimal control problem based on the linear quadratic regulator (LQR) approach. A comparison of several LQR controllers is provided to allow for tackling the considered multi-objective problems. Simulation results in frequency and time domains show that the use of two active anti-roll bars (front and rear axles) drastically improves the roll stability of the single unit heavy vehicle compared with the passive anti-roll bar.

  19. Trade-offs mathematical modelling of 3DCE in new product development: real three dimensions and directions for development

    Science.gov (United States)

    Ilhami, M. A.; Subagyo; Masruroh, N. A.

    2018-04-01

    In the last two decades, coordinating product, process, and supply chain has become the main focus in recent years as a growing body of research, which mathematical modelling is leading technique used in the early phase design. In this paper, we aim to conduct a comprehensive literature review of published paper and propose directions for future research, especially in mathematical modelling. Our findings exhibit fact that evidently there are only a few papers coordinate “real three dimensions”. The other papers, in fact, show simply two dimensions. Finally, some suggestions are proposed such as paying more attention to “real three dimensions” research-based and more focus on minimizing time to market, product life cycle consideration, and product rollover.

  20. Inspection and repair apparatus for a nuclear reactor fuel assembly

    International Nuclear Information System (INIS)

    Shallenberger, J.M.; Hornak, L.P.; Desmarchais, W.E.

    1975-01-01

    An apparatus is disclosed for inspecting and repairing a radioactive fuel assembly. The radioactive fuel assembly is positioned within a shielding sleeve which substantially reduces the level of radioactivity immediately surrounding the sleeve thereby permitting direct access by operating personnel. In one embodiment, a rotatable collar is mounted to the sleeve at a midlength location. An access port, an inspection port and an instrument port are included with the collar so that operating personnel may directly inspect the fuel assembly and effectuate any necessary repairs

  1. Impact of short-term hemodialysis catheters on the central veins: a catheter venographic study

    Energy Technology Data Exchange (ETDEWEB)

    Oguzkurt, Levent E-mail: loguzkurt@yahoo.com; Tercan, Fahri; Torun, Dilek; Yildirim, Tuelin; Zuemruetdal, Ayseguel; Kizilkilic, Osman

    2004-12-01

    Objective: To determine the incidence of pericatheter sleeve formation, thrombus formation, and stenosis of the central veins in hemodialysis patients with temporary catheters. Methods and material: In this prospective study, 57 patients (40 males, 17 females) with temporary dialysis catheters had catheter venography by pulling back the catheter just before removal. Patient's age range was 25-87 years (mean age, 51 years). The venographic studies were evaluated for pericatheter sleeve formation, thrombus formation, and stenosis of the brachiocephalic vein (BCV) and the superior vena cava (SVC). The IJV could only be evaluated if there was adequate filling during contrast administration. In a subgroup of patients who had had only right IJV or only right SCV catheters, impact of these catheters on the central veins was compared. Results: The catheter location was right internal jugular vein (IJV) in 26 cases, right subclavian vein (SCV) in 27 cases, left IJV in 1 case, and left SCV in 3 cases. Thirty-two patients (56%) had had only one temporary catheter and the rest had had more than one inserted. The mean dwell time for the catheters was 21 days (range 7-59 days). A pericatheter sleeve was detected on venography in 32 (56%) patients and thrombus formation was noted in 16 patients (28%). A total of 41 patients (72%) exhibited pericatheter sleeve and/or thrombus formation. While 19 of the 32 patients (59%) without previous catheterization had a sleeve around the catheter, only 13 (52%) of 25 patients who had had multiple catheters inserted had a sleeve (P>0.05). Of the eight patients (14%) with BCV stenosis, two had >50% stenosis. Only one patient (2%) had mild stenosis of the SVC. Three patients out of 15 (20%) who had diagnostic venography for the IJV had severe stenosis of the vein. Pericatheter sleeve formation was more frequent in women (P<0.05). However, there were no statistical differences with respect to pericatheter sleeve formation, luminal filling

  2. Poly(D,L-Lactide-Co-Glycolide) Tubes With Multifilament Chitosan Yarn or Chitosan Sponge Core in Nerve Regeneration.

    Science.gov (United States)

    Wlaszczuk, Adam; Marcol, Wiesław; Kucharska, Magdalena; Wawro, Dariusz; Palen, Piotr; Lewin-Kowalik, Joanna

    2016-11-01

    The influence of different kinds of nerve guidance conduits on regeneration of totally transected rat sciatic nerves through a 7-mm gap was examined. Five different types of conduits made of chitosan and poly(D,L-lactide-co-glycolide) (PLGA) were constructed and tested in vivo. We divided 50 animals into equal groups of 10, with a different type of conduit implanted in each group: chitosan sponge core with an average molecular mass of polymer (Mv) of 287 kDa with 7 channels in a PLGA sleeve, chitosan sponge core with an Mv of 423 kDa with 7 channels in a PLGA sleeve, chitosan sponge core (Mv, 423 kDa) with 13 channels in a PLGA sleeve, chitosan multifilament yarn in a PLGA sleeve, and a PLGA sleeve only. Seven weeks after the operation, we examined the distance covered by regenerating nerve fibers, growing of nerves into the conduit's core, and intensity and type of inflammatory reaction in the conduit, as well as autotomy behavior (reflecting neuropathic pain intensity) in the animals. Two types of conduits were allowing nerve outgrowth through the gap with minor autotomy and minor inflammatory reactions. These were the conduits with chitosan multifilament yarn in a PLGA sleeve and the conduits with 13-channel microcrystalline chitosan sponge in a PLGA sleeve. The type of chitosan used to build the nerve guidance conduit influences the intensity and character of inflammatory reaction present during nerve regeneration, which in turn affects the distance crossed by regenerating nerve fibers, growing of the nerve fibers into the conduit's core, and the intensity of autotomy in the animals. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Containment penetration design and analysis by finite element methods

    International Nuclear Information System (INIS)

    Perry, R.F.; Rigamonti, G.; Dainora, J.

    1975-01-01

    Containment penetration designs which provide complete support to process piping containing high pressure and high temperature fluids and which do not employ cooling coils, require special provisions to sustain loadings associated with normal/abnormal conditions and to limit maximum temperature transmitted to the containment concrete wall. In order to accomodate piping loads and fluid temperatures within code and regulatory limitations, the containment penetration designs require careful analysis of two critical regions: 1) the portion of the penetration sleeve which is exposed to containment ambient conditions and 2) the portion of the penetration which connects the sleeve to process piping (flued head). Analytical models using finite element representation of process piping, penetration flued head, and exposed sleeve were employed to investigate the penetration assembly design. By application of flexible multi-step analyses, different penetration configurations were evaluated to determine the effects of key design parameters. Among the parameters studied were flued head angles with the process piping, sleeve length and wall thickness. Special designs employing fins welded to the sleeve to further lower the temperature at the concrete wall interface were also investigated and fin geometry effects reported. (Auth.)

  4. The Effect of Roux-en-Y Gastric Bypass and Sleeve Gastrectomy Surgery on Dietary Intake, Food Preferences, and Gastrointestinal Symptoms in Post-Surgical Morbidly Obese Lebanese Subjects: A Cross-Sectional Pilot Study.

    Science.gov (United States)

    El Labban, Sibelle; Safadi, Bassem; Olabi, Ammar

    2015-12-01

    Data on gastrointestinal (GI) and dietary changes following bariatric surgery are scarce in the Middle Eastern region. The objective of this work was to retrospectively compare dietary intake, food preferences, and GI symptoms in subjects with extreme obesity after Roux-en-Y gastric bypass (RYGB) and sleeve gastrectomy (SG). Sixty subjects equally divided between RYGB and SG with a postoperative period of ≥6 months were recruited for a retrospective, non-randomized, and observational study. All subjects completed three questionnaires (GI symptoms, food preferences, and quantitative food frequency questionnaire (FFQ)) and three 24-h recalls. At one year postoperatively, both surgical groups showed similar percentage of excess weight loss that exceeded 50%. In addition, percentage of carbohydrate, protein, and sugar intake from total energy, frequency of daily consumption from the eight food categories and daily energy intake were comparable between surgical groups. RYGB subjects consumed significantly more fruits and juices from total energy (P fast heartbeat (P food preferences between RYGB and SG groups. There was a trend for sweet-eating in SG subjects with less dumping symptoms to suggest different mechanisms of action for each procedure, which might impact eating behavior.

  5. Transpiring purging access probe for particulate laden or hazardous environments

    Science.gov (United States)

    VanOsdol, John G

    2013-12-03

    An access probe for remote-sensing access through a viewing port, viewing volume, and access port into a vessel. The physical boundary around the viewing volume is partially formed by a porous sleeve lying between the viewing volume and a fluid conduit. In a first mode of operation, a fluid supplied to the fluid conduit encounters the porous sleeve and flows through the porous material to maintain the viewing volume free of ash or other matter. When additional fluid force is needed to clear the viewing volume, the pressure of the fluid flow is increased sufficiently to slidably translate the porous sleeve, greatly increasing the flow into the viewing volume. The porous sleeve is returned to position by an actuating spring. The access probe thereby provides for alternate modes of operation based on the pressure of an actuating fluid.

  6. Experimental study of some mounting brackets to support fuel elements

    International Nuclear Information System (INIS)

    Aubert, M.; Poglia, S.; Roche, R.

    1958-09-01

    In an atomic pile with vertical channels, fuel elements are stacked on one another. According to a possible assembly, fuel element can be contained by a graphite sleeve and be supported by a mounting bracket in this sleeve. Sleeves are then stacked on one another. The authors report the investigation of different designs for these mounting brackets. They describe their mechanical role and their mechanical, aerodynamic, neutronic and test conditions. They report tests performed on brackets made in graphite and on brackets made in stainless steel and graphite, and discuss the obtained results

  7. Absorber rod driving into a gas-cooled nuclear reactor

    International Nuclear Information System (INIS)

    Elter, C.; Schmitt, H.; Schoening, J.

    1987-01-01

    The absorber rod consists of a hollow cylinder which has a layer of absorber material applied on its inside circumferential surface. The absorber rod is held via a guide sleeve, which is supported centrally in a hole in the side reflector. The guidance within the sleeve is provided by flanges on the hollow cylinder. The movement of the hollow cylinder is carried out hydraulically or pneumatically. A flow of cooling gas is used for cooling, which is passed through the inner central areas of the hollow cylinder and the guide sleeve. (DG) [de

  8. Stress analysis of biomass fuel molding machine piston type stamping forming cone

    Directory of Open Access Journals (Sweden)

    Wu Gaofeng

    2015-01-01

    Full Text Available It is established the ram biomass straw machine as the analysis object in this paper,the molding machine cones of stress in the forming process of the analysis of the system. We used pottery instead of Wear-resistant cast iron for improving the performance of forming sleeve. The structure of the forming sleeve was analyzed with the mechanical module of a soft named Pro/engineer in this paper. The result indicated that the program was feasible. With the sensitivity analysis we identified the suitable angle for the sleeve.

  9. Efficacy and Safety of the Over-the-Scope Clip (OTSC) System in the Management of Leak and Fistula After Laparoscopic Sleeve Gastrectomy: a Systematic Review.

    Science.gov (United States)

    Shoar, Saeed; Poliakin, Lauren; Khorgami, Zhamak; Rubenstein, Rebecca; El-Matbouly, Moamena; Levin, Jun L; Saber, Alan A

    2017-09-01

    Endoscopic management of leaks/fistulas after laparoscopic sleeve gastrectomy (LSG) is gaining popularity in the bariatric surgery. This study aimed to review the efficacy and safety of over-the-scope-clip (OTSC) system in endoscopic closure of post-LSG leak/fistula. PubMed/Medline and major journals of the field were systematically reviewed for studies on endoscopic closure of post-LSG leaks/fistula by means of the OTSC system. A total of ten eligible studies including 195 patients with post-LSG leaks/fistula were identified. The time between LSG and leak/fistula ranged from 1 day to 803 days. Most of the leaks/fistula were located at the proximal staple line, and they sized from 3 to 20 mm. Time between leak diagnosis and OTSC clipping ranged from 0 to 271 days. Thirty-three out of 53 patients (63.5%) required one clip for closure of the lesion. Regarding the OTSC-related complications, a leak occurred in five patients (9.3%) and OTSC migration, stenosis, and tear each in one patient (1.8%). Of the 73 patients with post-LSG leak treated with OTSC, 63 patients had an overall successful closure (86.3%). OTSC system is a promising endoscopic approach for management of post-LSG leaks in appropriately selected patients. Unfortunately, most studies are series with a small sample size, short-term follow-up, and mixed data of concomitant procedures with OTSC. Further studies should distinguish the net efficacy of the OTSC system from other concomitant procedures in treatment of post-LSG leak.

  10. The Effect of Laparoscopic Sleeve Gastrectomy with Concomitant Hiatal Hernia Repair on Gastroesophageal Reflux Disease in the Morbidly Obese.

    Science.gov (United States)

    Samakar, Kamran; McKenzie, Travis J; Tavakkoli, Ali; Vernon, Ashley H; Robinson, Malcolm K; Shikora, Scott A

    2016-01-01

    The effect of laparoscopic sleeve gastrectomy (LSG) on gastroesophageal reflux disease (GERD) is controversial. Although concomitant hiatal hernia repair (HHR) at the time of LSG is common and advocated by many, there are few data on the outcomes of GERD symptoms in these patients. The aim of this study was to evaluate the effect of concomitant HHR on GERD symptoms in morbidly obese patients undergoing LSG. A single institution, multi-surgeon, prospectively maintained database was examined to identify patients who underwent LSG and concomitant HHR from December 2010 to October 2013. Patient characteristics, operative details, and postoperative outcomes were analyzed. Standardized patient questionnaires administered both pre- and postoperatively were utilized. Primary endpoints included subjective reflux symptoms and the need for antisecretory therapy. Weight loss was considered a secondary endpoint. Fifty-eight patients were identified meeting inclusion criteria (LSG + HHR), with a mean follow-up of 97.5 weeks (range 44-172 weeks). The mean age of the cohort was 49.5 ± 11.2 years, with 74.1 % being female. Mean preoperative BMI was 44.2 ± 6.6 kg/m(2). Preoperative upper gastrointestinal contrast series was performed in all patients and demonstrated a hiatal hernia in 34.5 % of patients and reflux in 15.5 % of patients. Preoperatively, 44.8 % (n = 26) of patients reported subjective symptoms of reflux and/or required daily antisecretory therapy [Corrected]. After LSG + HHR, 34.6 % of symptomatic patients had resolution of their symptoms off therapy while the rest remained symptomatic and required daily antisecretory therapy; 84.4 % of patients that were asymptomatic preoperatively remained asymptomatic after surgery. New onset reflux symptoms requiring daily antisecretory therapy was seen in 15.6 % of patients who were previously asymptomatic. Post surgical weight loss did not correlate with the presence or resolution of reflux symptoms. Based

  11. Containment penetration design criteria and implementation

    International Nuclear Information System (INIS)

    Perry, R.F.; Rigamonti, G.; Dainora, J.

    1975-01-01

    A rational design criteria is presented which serves as a basis for the design and analysis of containment piping penetrations. The criteria includes the effect of temperature as well as mechanical loads for the full range of plant conditions. With this criteria various penetration flued head designs have been compared and optimization achieved. Sleeve wall dimensions and containment loads have been determined without reference to piping configuration. An interaction theory which allows the implementation of the criteria for the determination of design loads and minimum sleeve wall thickness. The interaction theory developed applies to elastic-perfectly plastic cylinders (pipes and sleeves) and accounts for the simultaneous load resultants of transverse shear force, bending moment, torsional moment, and axial force in addition to internal pipe pressure. Application of the theory developed to the determination of sleeve thickness and containment design loads is presented in detail. (Auth.)

  12. Self-actuating and locking control for nuclear reactor

    International Nuclear Information System (INIS)

    Chung, D.K.

    1982-01-01

    A flow cutoff valve that is particularly suited for use with fluid-supported neutron absorber elements is described. The valve comprises a vertical elongated housing containing an apertured plate, an elongated nozzle member, and a flow cutoff sleeve. The nozzle has an opening in the bottom for receiving fluid and apertures near the top end for discharging fluid, as well as two sealing surfaces located above and below the apertures. The flow cutoff sleeve has walls surrounding the nozzle, a fluid flow opening at its upper end, and two sealing surfaces. The sleeve may move between an upper open position where the nozzle apertures are unobstructed, and a lower position in which the sleeve and nozzle sealing surfaces are mated and the flow of fluid through the nozzle apertures is blocked. Once the valve is in a closed position an increase in fluid pressure will keep it closed

  13. Feasibility and Safety of Endovascular Stripping of Totally Implantable Venous Access Devices

    International Nuclear Information System (INIS)

    Heye, Sam; Maleux, Geert; Goossens, G. A.; Vaninbroukx, Johan; Jerôme, M.; Stas, M.

    2012-01-01

    Purpose: To evaluate the safety and feasibility of percutaneous stripping of totally implantable venous access devices (TIVAD) in case of catheter-related sleeve and to report a technique to free the catheter tip from vessel wall adherence. Materials and Methods: A total of 37 stripping procedures in 35 patients (14 men, 40%, and 21 women, 60%, mean age 53 ± 14 years) were reviewed. Totally implantable venous access devices were implanted because of malignancy in most cases (85.7%). Catheter-related sleeve was confirmed as cause of persistent catheter dysfunction despite instillation of thrombolytics. A technique to mobilize the catheter tip from the vessel wall was used when stripping with the snare catheter was impossible. Technical success, complication rate, and outcome were noted. Results: A total of 55.9% (n = 19) of the 34 technically successful procedures (91.9%) could be done with the snare catheter. In 15 cases (44.1%), additional maneuvers to free the TIVAD’s tip from the vessel wall were needed. Success rate was not significantly lower before (72.4%) than after (96.7%) implementation of the new technique (P = 0.09). No complications were observed. Follow-up was available in 67.6% of cases. Recurrent catheter dysfunction was found in 17 TIVADs (78.3%) at a mean of 137.7 days and a median of 105 days. Conclusions: Stripping of TIVADs is technically feasible and safe, with an overall success rate of 91.9%. Additional endovascular techniques to mobilize the distal catheter tip from the wall of the superior vena cava or right atrium to allow encircling the TIVAD tip with the snare catheter may be needed in 44.1% of cases.

  14. Lower fetuin-A, retinol binding protein 4 and several metabolites after gastric bypass compared to sleeve gastrectomy in patients with type 2 diabetes.

    Directory of Open Access Journals (Sweden)

    Mia Jüllig

    Full Text Available BACKGROUND: Bypass of foregut secreted factors promoting insulin resistance is hypothesized to be one of the mechanisms by which resolution of type 2 diabetes (T2D follows roux-en-y gastric bypass (GBP surgery. AIM: To identify insulin resistance-associated proteins and metabolites which decrease more after GBP than after sleeve gastrectomy (SG prior to diabetes remission. METHODS: Fasting plasma from 15 subjects with T2D undergoing GBP or SG was analyzed by proteomic and metabolomic methods 3 days before and 3 days after surgery. Subjects were matched for age, BMI, metformin therapy and glycemic control. Insulin resistance was calculated using homeostasis model assessment (HOMA-IR. For proteomics, samples were depleted of abundant plasma proteins, digested with trypsin and labeled with iTRAQ isobaric tags prior to liquid chromatography-tandem mass spectrometry analysis. Metabolomic analysis was performed using gas chromatography-mass spectrometry. The effect of the respective bariatric surgery on identified proteins and metabolites was evaluated using two-way analysis of variance and appropriate post-hoc tests. RESULTS: HOMA-IR improved, albeit not significantly, in both groups after surgery. Proteomic analysis yielded seven proteins which decreased significantly after GBP only, including Fetuin-A and Retinol binding protein 4, both previously linked to insulin resistance. Significant decrease in Fetuin-A and Retinol binding protein 4 after GBP was confirmed using ELISA and immunoassay. Metabolomic analysis identified significant decrease of citrate, proline, histidine and decanoic acid specifically after GBP. CONCLUSION: Greater early decrease was seen for Fetuin-A, Retinol binding protein 4, and several metabolites after GBP compared to SG, preceding significant weight loss. This may contribute to enhanced T2D remission observed following foregut bypass procedures.

  15. [Protective measures in laparoscopic resection for upper or mid rectal cancer and sigmoid colon cancer with transrectal specimen extraction surgery].

    Science.gov (United States)

    Fu, Chuangang; Zhou, Zhuqing; Han, Junyi; Lu, Bin; Gao, Wei; Zhu, Zhe; Jiang, Qixin; Ji, Fang; Du, Tao

    2017-10-25

    To introduce the use of a self-made specimen protective sleeve in laparoscopic resection for upper or mid rectal cancer and sigmoid colon cancer with transrectal specimen extraction surgery and the improvement of implantation method, so as to avoid and reduce bacterial contamination and tumor cell dissemination in abdominal cavity. During June 2015 and May 2017, 48 cases of high located rectal or sigmoid colon cancer were operated laparoscopically with natural orifices specimen extraction surgery (NOSES) using a self-made specimen protecting sleeve. Operation indication: (1) Rectum and sigmoid colon cancer with the distance of more than 6 cm from tumor inferior margin to dentate line. (2) The maximum diameter of intestine together with mesangial and tumor <7 cm by intraoperative judgment. (3) No anal and distal rectal surgery, no anorectal stenosis or lack of expansion capacity caused by trauma. (4) No ulcerative colitis, Crohn's disease or radiation proctitis. After transecting the rectum, the specimen protective sleeve was inserted through the right lower 12 mm main Trocar (This sleeve was tailored from the laparoscopic protective sleeve produced by China 3L Corporation, which was intercepted with 25-35 cm from one end of the sleeve according to the length of distal rectal retention. One end was ligated and the other was open with a ligature band. About 5 ml paraffin oil was used to rinse and lubricate during the operation). The rectal stump retained 7-8 cm in abdominal cavity. The transanal ligation part of the protective sleeve was cut off, then the stapler nail seat was inserted and specimen was pull out through the sleeve and rectum. There were 30 males and 18 females. The average age was (64.5±14.1) years, the BMI was (25.4±3.9) kg/m 2 , the tumor diameter was (3.3±1.1) cm, the maximum diameter of specimen was (5.4±1.5) cm and the length of specimen was (18.6±4.3) cm. Among these 48 cases, specimens of 36 patients were pulled out through inside of the

  16. 75 FR 61853 - Advisory Committee to the Internal Revenue Service; Meeting

    Science.gov (United States)

    2010-10-06

    ... taxation and tax reporting, withholding tax issues, Identity Theft, Form 1099-DIV, Box 10, foreign tax paid... basis allocation for direct rollovers. Last minute agenda changes may preclude advance notice. Due to...

  17. [Bariatric and plastic surgery in obese adolescents: an alternative treatment].

    Science.gov (United States)

    Dubern, Béatrice; Tounian, Patrice

    2014-06-01

    The increased frequency of extreme forms of obesity in adolescents and the disappointing results of conventional treatments are now leading pediatricians to consider bariatric or cosmetic surgery as the only real long-term effective therapeutic alternative. The two main techniques currently used for bariatric surgery in adolescents are gastric bypass and adjustable gastric banding. Whatever the technique, weight loss is significant with improvement of comorbidities and quality of life. In addition, the complications are identical to those in adults and equally frequent. However, because of the particularities of this age, caution is still required. Adolescence is indeed characterized by specific nutritional needs, but also changes in body image in which surgery could have a negative effect. Currently, all obese teenagers making a request for bariatric surgery should have a comprehensive assessment with global care for at least 6 months. The indication is then discussed on a case-by-case basis by multidisciplinary teams and experts. To date, the type of surgery (gastric banding, gastric sleeve, or bypass) is still widely discussed. Based on experience with adults, we believe that gastric sleeve and bypass should be preferred. In addition, obesity in adolescents almost always involves psychosocial consequences, while somatic complications are rare. Thus, the care of adipo- or gynecomastia, abdominal fat excess, and concealed penis is essential and therefore justifies cosmetic surgery. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  18. 77 FR 65501 - Airworthiness Directives; The Boeing Company Airplanes

    Science.gov (United States)

    2012-10-29

    ... done. (g) Retained Replacement of Wiring, Installation of Sleeving, and Associated Actions This... requires replacing wiring for the fuel boost pumps and override pumps with new wiring, installing Teflon sleeving on the wiring, and doing associated actions; and doing repetitive inspections to detect damage of...

  19. 78 FR 10499 - Airworthiness Directives; The Boeing Company Airplanes

    Science.gov (United States)

    2013-02-14

    ... done. (g) Retained Replacement of Wiring, Installation of Sleeving, and Associated Actions This... replacing wiring for the fuel boost pumps and override pumps with new wiring, installing Teflon sleeving on the wiring, and doing associated actions; and doing repetitive inspections to detect damage of the...

  20. 75 FR 12667 - Airworthiness Directives; Learjet Inc. Model 45 Airplanes

    Science.gov (United States)

    2010-03-17

    ... corroded and cracked. Three additional airplanes were discovered to contain similar corrosion on the ballnut sleeves. The root cause is galvanic corrosion due to an aluminum sleeve installed on a steel... Aerospace, Project Coordinator--Fielding Specialist, Customer Support Engineering, One Learjet Way, P.O. Box...