WorldWideScience

Sample records for rocker arms pivotally

  1. Shaping the Strength of Cast Rocker Arm for Special Purpose Vehicle

    OpenAIRE

    Żuczek R.; Pysz S.; Maj M.; Piekło J.

    2015-01-01

    The article discusses the weldment to casting conversion process of rocker arm designed for operation in a special purpose vehicle to obtain a consistency of objective functions, which assume the reduced weight of component, the reduced maximum effort of material under the impact of service loads achieved through topology modification for optimum strength distribution in the sensitive areas, and the development of rocker arm manufacturing technology. As a result of conducted studies, the unit...

  2. Shaping the Strength of Cast Rocker Arm for Special Purpose Vehicle

    Directory of Open Access Journals (Sweden)

    Żuczek R.

    2015-09-01

    Full Text Available The article discusses the weldment to casting conversion process of rocker arm designed for operation in a special purpose vehicle to obtain a consistency of objective functions, which assume the reduced weight of component, the reduced maximum effort of material under the impact of service loads achieved through topology modification for optimum strength distribution in the sensitive areas, and the development of rocker arm manufacturing technology. As a result of conducted studies, the unit weight of the item was reduced by 25%, and the stress limit values were reduced to a level guaranteeing safe application.

  3. Controlled, Rapid Uprighting of Molars: A surprisingly Simple Solution The Pivot Arm Appliance.

    Science.gov (United States)

    Warise, Timothy R; Galella, Steve A

    2015-01-01

    In orthodontic cases where the regional anatomy provides limited room for eruption, there is etiologically a higher occurrence of tipped/impacted second molars. Although second molar extraction with third molar replacement is a useful option, the "Pivot Arm Appliance" encourages the uprighting of the second molar as a preferred treatment. The most unique and important attribute of the "Pivot Arm Appliance" is the rotating tube. In cases of access limitation, the disto-occlusal surface of the molar presents as one area that is accessible. Other features of the "Pivot Arm Appliance" include: The position of the rotator tube delivers optimal rotational force through the pivoting action of the tube/arm complex. The "Pivot Arm Appliance" takes advantage of the efficiency and simplicity of a Class I lever system. The anatomical fulcrum being the dense cortical bone located anterior to the ascending ramus. The vertical spring system is compact, reliable and delivers gentle controlled force in rotational direction. The lingual location of the "Pivot Arm Appliance" does not hinder the function of the tongue, impinge on the soft tissue or interfere with normal masticatory function. The ease of placement of the rotator tube and subsequent insertion of the spring. It is well to note the uprighting appliance provides a very useful and practical approach to the unique problem of severely tipped second molars with limited buccal access. The "Pivot Arm Appliance" does not function only in these situations but can be used in all cases of second molar uprighting of a moderate to severe nature.

  4. Stiffness Effects in Rocker-Soled Shoes: Biomechanical Implications

    Science.gov (United States)

    Su, Pei-Fang; Chung, Chia-Hua; Hsia, Chi-Chun; Chang, Chih-Han

    2017-01-01

    Rocker-soled shoes provide a way to reduce the possible concentration of stress, as well as change movement patterns, during gait. This study attempts to examine how plantar force and spatio-temporal variables are affected by two rocker designs, one with softer and one with denser sole materials, by comparing them with the barefoot condition and with flat-soled shoes. Eleven subjects’ gait parameters during walking and jogging were recorded. Our results showed that compared with barefoot walking, plantar forces were higher for flat shoes while lower for both types of rocker shoes, the softer-material rocker being the lowest. The plantar force of flat shoes is greater than the vertical ground reaction force, while that of both rocker shoes is much less, 13.87–30.55% body weight. However, as locomotion speed increased to jogging, for all shoe types, except at the second peak plantar force of the denser sole material rocker shoes, plantar forces were greater than for bare feet. More interestingly, because the transmission of force was faster while jogging, greater plantar force was seen in the rocker-soled shoes with softer material than with denser material; results for higher-speed shock absorption in rocker-soled shoes with softer material were thus not as good. In general, the rolling phenomena along the bottom surface of the rocker shoes, as well as an increase in the duration of simultaneous curve rolling and ankle rotation, could contribute to the reduction of plantar force for both rocker designs. The possible mechanism is the conversion of vertical kinetic energy into rotational kinetic energy. To conclude, since plantar force is related to foot-ground interface and deceleration methods, rocker-design shoes could achieve desired plantar force reduction through certain rolling phenomena, shoe-sole stiffness levels, and locomotion speeds. PMID:28046009

  5. Stiffness Effects in Rocker-Soled Shoes: Biomechanical Implications.

    Directory of Open Access Journals (Sweden)

    Shih-Yun Lin

    Full Text Available Rocker-soled shoes provide a way to reduce the possible concentration of stress, as well as change movement patterns, during gait. This study attempts to examine how plantar force and spatio-temporal variables are affected by two rocker designs, one with softer and one with denser sole materials, by comparing them with the barefoot condition and with flat-soled shoes. Eleven subjects' gait parameters during walking and jogging were recorded. Our results showed that compared with barefoot walking, plantar forces were higher for flat shoes while lower for both types of rocker shoes, the softer-material rocker being the lowest. The plantar force of flat shoes is greater than the vertical ground reaction force, while that of both rocker shoes is much less, 13.87-30.55% body weight. However, as locomotion speed increased to jogging, for all shoe types, except at the second peak plantar force of the denser sole material rocker shoes, plantar forces were greater than for bare feet. More interestingly, because the transmission of force was faster while jogging, greater plantar force was seen in the rocker-soled shoes with softer material than with denser material; results for higher-speed shock absorption in rocker-soled shoes with softer material were thus not as good. In general, the rolling phenomena along the bottom surface of the rocker shoes, as well as an increase in the duration of simultaneous curve rolling and ankle rotation, could contribute to the reduction of plantar force for both rocker designs. The possible mechanism is the conversion of vertical kinetic energy into rotational kinetic energy. To conclude, since plantar force is related to foot-ground interface and deceleration methods, rocker-design shoes could achieve desired plantar force reduction through certain rolling phenomena, shoe-sole stiffness levels, and locomotion speeds.

  6. Effect of rocker shoes on plantar pressure pattern in healthy female runners

    NARCIS (Netherlands)

    Sobhani, Sobhan; van den Heuvel, Edwin; Bredeweg, Steven; Kluitenberg, Bas; Postema, Klaas; Hijmans, Juha M.; Dekker, Rienk

    Rocker profile shoes (rocker shoes) are one of the treatment options of metatarsalgia and forefoot stress fractures. The efficacy of rocker shoes in unloading the forefoot pressure has been shown in walking. In running, however, the effect of rocker shoes on forefoot pressure is unknown. Eighteen

  7. Flowet i rocker/bandemiljøerne

    DEFF Research Database (Denmark)

    Klement, Christian; Kyvsgaard, Britta

    gennemstrømning i rocker/bandemiljøerne i løbet af den undersøgte periode. Næsten halvdelen af de 2.647 personer, der af politiet er registreret som medlemmer af disse grupperinger på de nævnte tidspunkter, er nytilkomne, idet de først indgår i PED-registeret i 2012 eller 2013. Dertil kommer, at knap en tredjedel...... af de 2.647 personer er op-hørt med at være aktive i rocker/bandegrupperingerne, idet de i løbet af perioden slettes af registe-ret. Det betyder, at det kun er en lille femtedel (19 pct.) af de PED-registrerede, der har været med-lemmer i hele den periode, oplysningerne angår. Rocker/bandemiljøet er......-derforstået, at meget få dermed forlader rocker/bandemiljøet. De gennemførte analysere viser imid-lertid tydeligt, at vældig mange er i stand til at forlade miljøet uden hjælp fra exit. Omvendt viser rapporten også, at der har været en stor tilgang til miljøerne, og at rockerklubberne og banderne således tilsyneladende...

  8. On the Controllability and Observability of Actively Lubricated Journal Bearings with Pads Featuring Different Nozzle-Pivot Configurations

    DEFF Research Database (Denmark)

    Salazar, Jorge Andrés González; Santos, Ilmar

    2017-01-01

    tilt angle, (iii) the vertical pad movement-due to the pivot flexibility, and (iv) the controllable force as the hydraulic DOF. The test rig consists of a rigid rotor supported by a single rocker-pivoted rigid pad. A thorough parametric study is carried out by investigating the effects of: (a) nozzle-pivot...... offset, (b) pivot flexibility, and (c) bearing loading on these control basics in order to determine the pad with the best control characteristics. Different nozzle-pivot offsets can be set by varying the positioning of either the injection nozzle or the pivot line. The influence of the pivot compliance...... on the bearing dynamics is assessed by benchmarking the results obtained with the flexible pivot against the rigid pivot. Three different bearing loads are studied. According to the results, the proposed configurations, especially the offset-pivot pad with slight offsets, improve the bearing control...

  9. Effect of rocker-soled shoes on parameters of knee joint load in knee osteoarthritis.

    Science.gov (United States)

    Madden, Elizabeth G; Kean, Crystal O; Wrigley, Tim V; Bennell, Kim L; Hinman, Rana S

    2015-01-01

    This study evaluated the immediate effects of rocker-soled shoes on parameters of the knee adduction moment (KAM) and pain in individuals with knee osteoarthritis (OA). Three-dimensional gait analysis was performed on 30 individuals (mean (SD): age, 61 (7) yr; 15 (50%) male) with radiographic and symptomatic knee OA under three walking conditions in a randomized order: i) wearing rocker-soled shoes (Skechers Shape-ups), ii) wearing non-rocker-soled shoes (ASICS walking shoes), and iii) barefoot. Peak KAM and KAM angular impulse were measured as primary indicators of knee load distribution. Secondary measures included the knee flexion moment (KFM) and knee pain during walking. Peak KAM was significantly lower when wearing the rocker-soled shoes compared with that when wearing the non-rocker-soled shoes (mean difference (95% confidence interval), -0.27 (-0.42 to -0.12) N·m/BW × Ht%; P < 0.001). Post hoc tests revealed no significant difference in KAM impulse between rocker-soled and non-rocker-soled shoe conditions (P = 0.13). Both peak KAM and KAM impulse were significantly higher during both shoe conditions compared with those during the barefoot condition (P < 0.001). There were no significant differences in KFM (P = 0.36) or knee pain (P = 0.89) between conditions. Rocker-soled shoes significantly reduced peak KAM when compared with non-rocker-soled shoes, without a concomitant change in KFM, and thus may potentially reduce medial knee joint loading. However, KAM parameters in the rocker-soled shoes remained significantly higher than those during barefoot walking. Wearing rocker-soled shoes did not have a significant immediate effect on walking pain. Further research is required to evaluate whether rocker-soled shoes can influence symptoms and progression of knee OA with prolonged wear.

  10. Dynamic Rocker-Bogie: Kinematical Analysis in a High-Speed Traversal Stability Enhancement

    Directory of Open Access Journals (Sweden)

    Sunxin Wang

    2016-01-01

    Full Text Available The rocker-bogie suspension system has robust capabilities to deal with uneven terrain because of its distributing of the payload over its six wheels uniformly, while there is one major shortcoming to high-speed traversal over the planar terrain. This paper proposes a new dynamic rocker-bogie suspension system with two modes of operation: it can expand the span of the rocker-bogie support polygon to increase travel rate when the terrain is planar; and it can switch to its original configuration to move by low speed when it is faced with rough terrain. The analysis on dynamic stability margin and kinematical simulation on the two operating modes of rocker-bogie are employed to analyze and verify the rationality and effectiveness of the modification in the structure.

  11. Trajectory generation algorithm for smooth movement of a hybrid-type robot Rocker-Pillar

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Seung Min; Choi, Dong Kyu; Kim, Jong Won [School of Mechanical and Aerospace Engineering, Seoul National University, Seoul (Korea, Republic of); Kim, Hwa Soo [Dept. of Mechanical System Engineering, Kyonggi University, Suwon (Korea, Republic of)

    2016-11-15

    While traveling on rough terrain, smooth movement of a mobile robot plays an important role in carrying out the given tasks successfully. This paper describes the trajectory generation algorithm for smooth movement of hybrid-type mobile robot Rocker-Pillar by adjusting the angular velocity of its caterpillar as well as each wheel velocity in such a manner to minimize a proper index for smoothness. To this end, a new Smoothness index (SI) is first suggested to evaluate the smoothness of movement of Rocker-Pillar. Then, the trajectory generation algorithm is proposed to reduce the undesired oscillations of its Center of mass (CoM). The experiment are performed to examine the movement of Rocker-Pillar climbing up the step whose height is twice larger than its wheel radius. It is verified that the resulting SI is improved by more than 40 % so that the movement of Rocker-Pillar becomes much smoother by the proposed trajectory algorithm.

  12. Rocker shoe, minimalist shoe, and standard running shoe : A comparison of running economy

    NARCIS (Netherlands)

    Sobhani, Sobhan; Bredeweg, Steven; Dekker, Rienk; Kluitenberg, Bas; van den Heuvel, Edwin; Hijmans, Juha; Postema, Klaas

    Objectives: Running with rocker shoes is believed to prevent lower limb injuries. However, it is not clear how running in these shoes affects the energy expenditure. The purpose of this study was, therefore, to assess the effects of rocker shoes on running economy in comparison with standard and

  13. Rocker: Open source, easy-to-use tool for AUC and enrichment calculations and ROC visualization.

    Science.gov (United States)

    Lätti, Sakari; Niinivehmas, Sanna; Pentikäinen, Olli T

    2016-01-01

    Receiver operating characteristics (ROC) curve with the calculation of area under curve (AUC) is a useful tool to evaluate the performance of biomedical and chemoinformatics data. For example, in virtual drug screening ROC curves are very often used to visualize the efficiency of the used application to separate active ligands from inactive molecules. Unfortunately, most of the available tools for ROC analysis are implemented into commercially available software packages, or are plugins in statistical software, which are not always the easiest to use. Here, we present Rocker, a simple ROC curve visualization tool that can be used for the generation of publication quality images. Rocker also includes an automatic calculation of the AUC for the ROC curve and Boltzmann-enhanced discrimination of ROC (BEDROC). Furthermore, in virtual screening campaigns it is often important to understand the early enrichment of active ligand identification, for this Rocker offers automated calculation routine. To enable further development of Rocker, it is freely available (MIT-GPL license) for use and modifications from our web-site (http://www.jyu.fi/rocker).

  14. Effects of a flat prosthetic foot rocker section on balance and mobility.

    Science.gov (United States)

    Hansen, Andrew; Nickel, Eric; Medvec, Joseph; Brielmaier, Steven; Pike, Alvin; Weber, Marilyn

    2014-01-01

    Previous studies have shown that the effective rocker shape of the physiologic ankle-foot system during standing and fore-aft swaying is much flatter than that used during walking, which indicates a more stable base of support for the standing/swaying activity. Previous work suggests that flat regions within the effective rocker shapes of prosthetic ankle-foot systems could provide enhanced stability for standing balance tasks. An experimental prosthetic foot was altered to provide three different flat region lengths within its effective rocker shape. It was hypothesized that longer flat regions of the effective rocker shape would lead to improved standing balance outcomes and reduced walking performance for unilateral transtibial prosthesis users. However, no significant changes were seen in the balance and mobility outcomes of 12 unilateral transtibial prosthesis users when using the three prosthetic foot conditions. Subjects in the study significantly preferred prosthetic feet with relatively low to moderate flat regions over those with long flat regions. All the subjects without loss of light touch or vibratory sensation selected the prosthetic foot with the shortest flat region. More work is needed to investigate the effects of prosthetic foot properties on balance and mobility of prosthesis users.

  15. Research Paper: Evaluation of the Effects of Two Types of Foot Rockers on the Temporal-Spatial Gait Parameters in Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Zeinab Rezaeian

    2016-07-01

    Conclusion The results of this study showed that the force-time integral of vertical component of the ground reaction force increased significantly in subjects with diabetes, which is the main cause of foot ulcers. Although, heel and toe rockers did not influence the force applied to the foot or the force-time integral, it is recommended to use rocker shoes with wide base of support to increase the dynamic stability while decreasing the foot pressure. The main limitation is that the immediate effect of use of rocker was studies in this study . It is recommended to check the effect of rockers interventions after a certain period of their use.

  16. Biomechanics of slow running and walking with a rocker shoe

    NARCIS (Netherlands)

    Sobhani, Sobhan; Hijmans, Juha; van den Heuvel, Edwin; Zwerver, Johannes; Dekker, Rienk; Postema, Klaas

    Evidence suggests a link between the loading of the Achilles tendon and the magnitude of the ankle internal plantar flexion moment during late stance of gait, which is clinically relevant in the management of Achilles tendinopathy. Some studies showed that rocker shoes can reduce the ankle internal

  17. A new piezo-driven microgripper based on the double-rocker mechanism

    International Nuclear Information System (INIS)

    Yang, Yi-ling; Wei, Yan-ding; Tian, Geng; Zhao, Xiao-wei; Fu, Lei; Lou, Jun-qiang

    2015-01-01

    This paper reports the design and modelling of a new piezo-driven microgripper with large output displacements. The design of the microgripper is based on the double-rocker mechanism and the parallelogram mechanism. The microgripper can produce a large output displacement and a parallel movement of the gripper tips. Theoretical models for the microgripper are derived using the pseudorigid-body-model method. Through several finite-element analysis simulations, the optimal geometric parameters of the microgripper are obtained, and the theoretical models are evaluated and verified. The performance of the proposed microgripper is demonstrated by several experiments, and a micromanipulation case is presented. The experimental results indicate that the microgripper with the double-rocker mechanism has a large output displacement of 213.9 μm and a large amplification ratio of 21.4. The microgripper is capable of multiscale micromanipulation. (paper)

  18. Attempt at classification of the dynamic state of rocker heads of the KGS-320 shearer loader on the basis of dimensionless amplitude-directional estimates

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, W; Zakrzewski, T [Politechnika Slaska, Gliwice (Poland)

    1989-01-01

    Evaluates problems associated with vibro-acoustic testing of rocker heads of the KGS-320 shearer loader manufactured in Poland. Effects of measuring point location on mechanical vibrations and acoustic emission were analyzed. Vibrations and acoustic emissuion of the rocker heads under conditions of idle run on a laboratory test stand were investigated. The investigations concentrated on operation of drive shafts but other main elements of a rocker head were also considered. Standard distribution and amplitudes of vibrations and acoustic emission generated by rocker heads were analyzed. A method for evaluating results of laboratory tests based on the classification of vibro-acoustic emission is discussed. 17 refs.

  19. Rockere og bandemedlemmers kriminelle karrierer og netværk i ungdommen

    DEFF Research Database (Denmark)

    Klement, Christian; Pedersen, Maria Libak

    2013-01-01

    rockergruppe eller en bande, da viden om sådanne mønstre kan hjælpe til at forudsige, hvilke unge der fremadrettet er i risiko for at blive involveret. Undersøgelsesmaterialet består af oplysninger om de personer, der er registreret som rockere eller bandemedlemmer i Politiets Efterretningsstøtte Database (PED......Denne rapport omhandler en undersøgelse af rockere og bandemedlemmers kriminelle karriere og kriminelle netværk i ungdomsårene og i den tidligere voksenalder. Formålet med undersøgelsen er at identificere eventuelle mønstre i kriminaliteten hos unge, der senere i livet bliver medlemmer af en......) og af kriminalitetsoplysninger fra Danmarks Statistik. I analyserne af den kriminelle karriere er der gjort brug af matchede kontrolper-soner, således at de personer, der senere bliver medlemmer af en rockergruppe eller en bande, sam-menlignes med andre lovovertrædere, der ligner dem med hensyn til...

  20. Kinematic analysis of postural reactions to a posterior translation in rocker bottom shoes in younger and older adults.

    Science.gov (United States)

    Kimel-Scott, Dorothy R; Gulledge, Elisha N; Bolena, Ryan E; Albright, Bruce C

    2014-01-01

    Shoes with rocker bottom soles are utilized by persons with diabetic peripheral neuropathy to reduce plantar pressures during gait. The risk of falls increases with age and is compounded by diabetic neuropathy. The purpose of this study was to analyze how rocker bottom shoes affect posture control of older adults (50-75 years old) and younger adults (20-35 years old) in response to posterior slide perturbations. The postural response to a posterior platform translation was normalized among subjects by applying the below threshold stepping velocity (BTSV) for each subject. The BTSV was the fastest velocity of platform translation that did not cause a stepping response while wearing the rocker bottom shoes. Joint excursion, time to first response, response time, and variability of mean peak joint angles were analyzed at the ankle, knee, hip, trunk, and head in the sagittal plane. The statistical analysis was a 2-factor mixed repeated measures design to determine interactions between and within shoe types and age groups. While wearing rocker bottom shoes, both age groups exhibited increased joint excursion, differences in time to initial response, and longer response time. The older group demonstrated decreased joint excursion and increased time to initial response compared to the younger group, as well as a significantly slower mean BTSV. These findings support the conclusion that in healthy older adults and in populations at risk for falls, the use of rocker bottom or other unstable shoes may increase the potential of falls when confronted with a standing perturbation such as a forceful slip or trip. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Predictors of response to prefabricated foot orthoses or rocker-sole footwear in individuals with first metatarsophalangeal joint osteoarthritis.

    Science.gov (United States)

    Menz, Hylton B; Auhl, Maria; Tan, Jade M; Levinger, Pazit; Roddy, Edward; Munteanu, Shannon E

    2017-05-12

    Osteoarthritis of the first metatarsophalangeal joint (1st MTPJ OA) is a common and disabling condition commonly managed with footwear and orthotic interventions. The objective of this study was to identify factors associated with a successful treatment response in people with 1st MTPJ OA provided with prefabricated orthoses or rocker-sole footwear as part of a randomised clinical trial. People with 1st MTPJ OA (n = 88) who participated in a randomised trial were allocated to receive prefabricated foot orthoses (n = 47) or rocker-sole footwear (n = 41) and completed a baseline questionnaire including information on demographics, anthropometrics, general health, pain characteristics (including the Foot Health Status Questionnaire [FHSQ] and Foot Function Index [FFI]) and perceptions of the interventions, and a clinical assessment of foot posture, range of motion, radiographic severity and in-shoe plantar pressures. Adherence was documented using diaries. At 12 weeks, participants documented their perception of improvement on a 15-point scale. Those reporting at least moderate improvement on this scale were classified as 'responders'. There were 29 responders (62%) in the orthoses group and 16 responders (39%) in the rocker-sole group. In the orthoses group, responders had greater baseline pain severity while walking, a higher FFI difficulty score, and wore their orthoses more frequently. In the rocker-sole group, responders had a higher FFI stiffness score and greater radiographic severity. However, the accuracy of these variables in identifying responders in each group was modest (62 and 53%, respectively). The response to prefabricated orthoses or rocker-sole footwear in people with 1st MTPJ OA is related to measures of increased pain and disease severity. However, the overall classification accuracy associated with these factors is not sufficient for identifying individuals who are most likely to benefit from these interventions. Australian New

  2. Fuel Lubricity Impact on Shipboard Engine and Fuel Systems and Sensitivity of U.S. Navy Diesel Engines to Low-Sulfur Diesel Fuel

    Science.gov (United States)

    2011-06-30

    load fuel and operated with a dummy injector to make sure the system was clean. The rig was de -fueled and a fresh charge of 2000-gram fuel was added...the rocker arm on the injector. The rocker arm contact was repositioned when it was noted it was hitting the injector off-center, and it was felt...going up. Figure B6. DD 149 Unit Injector with Diesel Fuel and Centered Rocker Arm Figure B7. Wear Rate Deviation Attributed to Head

  3. EFFECTIVENESS OF A NEW BALANCE TRAINING PROGRAM ON ROCKER BOARD IN SITTING IN STROKE SUBJECTS A PILOT STUDY

    Directory of Open Access Journals (Sweden)

    Sandesh Rayamajhi

    2014-06-01

    Full Text Available Background: Stroke has been considered to be the most common cause of neurological disability with very high prevalence rate. The recovery of independence following stroke is a complex process requiring the reacquisition of many skills. Since controlling the body’s position in space is essential part of functional skills, restoration of balance is a critical part of the recovery of ability after stroke. Most of the work done regarding balance training in stroke subjects has focused on task-oriented activities and training under varied sensory input and found them to be effective. Studies have also compared the effect of stable and unstable surfaces on balance in stroke subjects and found that balance training on unstable surfaces is more effective in improving static and dynamic balance. There has not been any study till date investigating the effectiveness of balance training program on rocker board which is specific for stroke subjects who have difficulty in standing. Since balance training on rocker board in sitting has proved to be effective in improving balance in subjects with spinal cord injury who have difficulty in standing, there is a need to find out if similar balance training program on rocker board in sitting is also effective for improving balance of stroke subjects. Method: A Pilot study was performed on 10 stroke subjects selected through purposive sampling. Subjects were divided into two groups by randomization as control (CG and experimental group (EG. EG received balance training on a rocker board along with conventional physiotherapy program. The CG received only conventional physiotherapy program. Results: Post-intervention Berg balance scale score of EG and the CG was statistically significant (p < 0.05 in both the groups as compared to pre-treatment depicted through Wilcoxon signed rank analysis within the groups. Greater improvement was observed in the EG compared to the CG post-treatment, analysed through Mann

  4. Mods and Rockers, Drunken Debutants, and Sozzled Students

    Directory of Open Access Journals (Sweden)

    Bill Thompson

    2012-07-01

    Full Text Available Over the last decade, moral panic theory has affected a paradigm shift in the social construction of deviance and social problems in the United States, without any real debate about its viability. This article raises key questions about this perspective by offering the first ever critique of the seminal case study of British youth subcultures on which the paradigm is based. It argues that when analyzed in the context of contemporary criticism of vandalism, hooliganism, and delinquency, the Mods and Rockers case study never justified Cohen’s original criteria for a moral panic.

  5. Tracer techniques for the investigation of wear mechanisms in coated or surface-treated machine parts

    International Nuclear Information System (INIS)

    Goedecke, T.; Grosch, J.

    1990-01-01

    Tracer techniques allow wear measurement down to rates of only some μg/h, and these measurements can be done continuously within an inspection test run, not requiring dismantling of the parts to be examined. The measurements revealed the materials pair of a chilled cast iron camshaft and a hard metal coated rocker arm to be superior in terms of wear behaviour over the materials pair of a malleable cast iron camshaft with induction hardening and a rocker arm with hard chromium plating. The total wear of a chilled cast iron camshaft was measured to be approx. 90% less than that of the malleable cast iron camshaft, under equal loading conditions. With the rocker arms, this ratio is approx. 1:3. Another disadvantage of the latter pair is the overall wear ratio of 19:1. The best wear resistance was measured with a TiN-coated rocker arm combined with a chilled cast iron camshaft. (orig./MM) [de

  6. Role of transpiration reduction during center-pivot sprinkler irrigation in application efficiency

    OpenAIRE

    Urrego Pereira, Yenny Fernanda; Cavero Campo, José; Medina Pueyo, Eva Teresa; Martínez-Cob, Antonio

    2013-01-01

    The magnitude and duration of corn transpiration reduction during center-pivot sprinkler irrigation was analyzed on a commercial plot. The irrigation event was defined as the period during which the pivot arm was passing over the transect AC and water droplets were moistening the plants (moist treatment). Corn transpiration rates were measured at three spots of that transect and simultaneously at another spot (dry treatment) located approximately 270 m east from the transect AC. Corn transpir...

  7. A Randomized Comparison of the Biomechanical Effect of Two Commercially Available Rocker Bottom Shoes to a Conventional Athletic Shoe During Walking in Healthy Individuals.

    Science.gov (United States)

    Talaty, Mukul; Patel, Sona; Esquenazi, Alberto

    2016-01-01

    Rocker bottom shoes have recently gained considerable popularity, likely in part because of the many purported benefits, including reducing joint loading and toning muscles. Scientific inquiry about these benefits has not kept pace with the increased usage of this shoe type. A fundamental premise of rocker bottom shoes is that they transform hard, flat, level surfaces into more uneven ones. Published studies have described a variety of such shoes-all having a somewhat rounded bottom and a cut heel region or a cut forefoot region, or both (double rocker). Despite the fundamentally similar shoe geometries, the reported effects of rocker bottom shoes on gait biomechanics have varied considerably. Ten healthy subjects agreed to participate in the present study and were given appropriately sized Masai Barefoot Technology (St. Louis, MO), Skechers(™) (Manhattan Beach, CA), and New Balance (Boston, MA) conventional walking shoes. After a 12-day accommodation period, the subjects walked wearing each shoe while 3-dimensional motion and force data were collected in the gait laboratory. The key findings included (1) increased trunk flexion, decreased ankle plantarflexion range, and reduced plantarflexion moment in the early stance; (2) increased ankle dorsiflexion and knee flexor moment in the midstance; (3) decreased peak ankle plantarflexion in the late stance; and (4) decreased ankle plantarflexion and decreased hip flexor and knee extensor moments in the pre-swing and into swing phase. The walking speed was unconstrained and was maintained across all shoe types. A biomechanical explanation is suggested for the observed changes. Suggestions for cautions are provided for using rocker bottom shoes in patients with neuromuscular insufficiency. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. The effect of footwear adapted with a multi-curved rocker sole in conjunction with knee-ankle-foot orthoses on walking in poliomyelitis subjects: a pilot study.

    Science.gov (United States)

    Mojaver, Ali; Arazpour, Mokhtar; Aminian, Gholamreza; Ahmadi Bani, Monireh; Bahramizadeh, Mahmood; Sharifi, Guive; Sherafatvaziri, Arash

    2017-10-01

    Knee-ankle-foot orthoses (KAFOs) are used by people with poliomyelitis to ambulate. Whist advances in orthotic knee joint designs for use in KAFOs such the provision of stance control capability have proven efficacy, little attention has been paid to shoe adaptations which may also improve gait. The aim of this study was to evaluate the alteration to the kinematics and temporal-spatial parameters of gait caused by the use of heel-to-toe rocker-soled footwear when ambulating with KAFOs. Nine adults with a history of poliomyelitis who routinely wore KAFOs participated in the study. A heel-to-toe rocker sole was added to footwear and worn on the affected side. A three-dimensional motion capture system was used to quantify the resulting alteration to specific gait parameters. Maximum hip joint extension was significantly increased (p = 0.011), and hip abduction and adduction were both significantly reduced (p = 0.011 and p = 0.007, respectively) when walking with the rocker sole. A significant increase in stride length (p = 0.035) was demonstrated but there were no significant increases in either walking speed or cadence. A heel-to-toe rocker sole adaptation may be useful for walking in patients with poliomyelitis who use KAFOs. Implications for Rehabilitation The poor functionality and difficulty in walking when using an orthotic device such as a KAFO which keeps the knee locked during ambulation, plus the significant energy required to walk, are complications of orthoses using. Little evidence exists regarding the biomechanical effect of walking with a KAFO incorporating fixed knee joints, in conjunction with rocker-soled footwear. The main aim of walking with a heel-to-toe rocker sole is to facilitate forward progression of the tibia when used with an AFO or KAFO or to provide easier walking for patients who have undergone an ankle arthrodesis. In this study, a rocker sole profile adaptation produced no significant alteration to hip joint flexion

  9. Optimisation of rocker sole footwear for prevention of first plantar ulcer: comparison of group-optimised and individually-selected footwear designs.

    Science.gov (United States)

    Preece, Stephen J; Chapman, Jonathan D; Braunstein, Bjoern; Brüggemann, Gert-Peter; Nester, Christopher J

    2017-01-01

    Appropriate footwear for individuals with diabetes but no ulceration history could reduce the risk of first ulceration. However, individuals who deem themselves at low risk are unlikely to seek out bespoke footwear which is personalised. Therefore, our primary aim was to investigate whether group-optimised footwear designs, which could be prefabricated and delivered in a retail setting, could achieve appropriate pressure reduction, or whether footwear selection must be on a patient-by-patient basis. A second aim was to compare responses to footwear design between healthy participants and people with diabetes in order to understand the transferability of previous footwear research, performed in healthy populations. Plantar pressures were recorded from 102 individuals with diabetes, considered at low risk of ulceration. This cohort included 17 individuals with peripheral neuropathy. We also collected data from 66 healthy controls. Each participant walked in 8 rocker shoe designs (4 apex positions × 2 rocker angles). ANOVA analysis was then used to understand the effect of two design features and descriptive statistics used to identify the group-optimised design. Using 200 kPa as a target, this group-optimised design was then compared to the design identified as the best for each participant (using plantar pressure data). Peak plantar pressure increased significantly as apex position was moved distally and rocker angle reduced ( p  footwear which was individually selected. In terms of optimised footwear designs, healthy participants demonstrated the same response as participants with diabetes, despite having lower plantar pressures. This is the first study demonstrating that a group-optimised, generic rocker shoe might perform almost as well as footwear selected on a patient by patient basis in a low risk patient group. This work provides a starting point for clinical evaluation of generic versus personalised pressure reducing footwear.

  10. Combustion Heat Release Rate Comparison of Algae Hydroprocessed Renewable Diesel to F-76 in a Two-Stroke Diesel Engine

    Science.gov (United States)

    2013-06-01

    was recorded. Figure 14 shows the gauge on the rocker arm during calibration . Figure 14. Mechanical Injector Rocker Arm Strain Gauge. D. DATA...RELEASE RATE COMPARISON OF ALGAE HYDROPROCESSED RENEWABLE DIESEL TO F-76 IN A TWO-STROKE DIESEL ENGINE by John H. Petersen June 2013 Thesis...RELEASE RATE COMPARISON OF ALGAE HYDROPROCESSED RENEWABLE DIESEL TO F-76 IN A TWO-STROKE DIESEL ENGINE 5. FUNDING NUMBERS 6. AUTHOR(S) John H

  11. Emergency disconnect means for the manipulator arm of a nuclear reactor vessel inspection apparatus

    International Nuclear Information System (INIS)

    Jacobs, F.; Morris, D.W.

    1980-01-01

    An emergency disconnect means is disclosed for uncoupling a portion of the linkage means which connects the several segments of an articulating manipulator arm employed in a nuclear reactor vessel inspection device. One of the motor housings included in the manipulator arm's segmented drive train is pivotably coupled between two segments thereof. In the event of power failure or the necessity of manual retraction of the manipulator arm from within the vessel, a lever is manually operated and moved from its normally locked position wherein the motor housing is positionally fixed to a release position wherein the motor housing and the remainder of the manipulator arm segments connected forwardly thereof are pivotally released to shorten the normal arm reach and alter the normal orientation of the manipulator arm to expedite removal without danger of collision. (auth)

  12. The Effect of Rocker Bar Ankle Foot Orthosis on Functional Mobility in Post-Stroke Hemiplegic Patients

    Directory of Open Access Journals (Sweden)

    Farzad Farmani

    2015-09-01

    Full Text Available Objectives: Ankle Foot Orthoses (AFOs are widely utilized to improve walking ability in hemiplegic patients. The present study aimed to evaluate the effect of Rocker bar Ankle Foot Orthosis (RAFO on functional mobility in post-stroke hemiplegic patients. Methods: Fifteen hemiplegic patients (men and women who were at least 6-months post-stroke and able to walk without assistive device for at least 10 meters voluntarily participated in this study. The patients were examined with and without RAFO. Their functional mobility was evaluated through 10-meter walk test and Timed Up and Go (TUG test. Also, paired t-test was used to analyze obtained data. Results: When patients used RAFO, their gait speed significantly increased (P<0.05. Also, the time of performing TUG test experienced a significant decrease using RAFO compared with utilizing shoe only (P<0.05. Discussion: RAFO led to a significant improvement in functional mobility in hemiplegic patient’s secondary to stroke. It seems that, it has been due to the positive effect of rocker modification on improving push off and transferring weight during stance phase of gait.

  13. The effect of the heel- to- toe rocker shoe on moments of ankle joint and temporal-spatial of gait in female student

    Directory of Open Access Journals (Sweden)

    masoomeh Veiskarami

    2015-01-01

    Full Text Available Background : Rocker shoes are the most commonly prescribed external therapeutic shoe modification and are used for treatment of the ankle and midfoot problems. The aim of this study was to assesse the effects of the heel- to-toe rocker shoes on temporal-spatial and ankle joint moments in sagital and frontal plane. Materials and Methods: In this quasi-exprimental study, three-dimentional gait analysis was carried out on 20 healthy university female students with normal normal gait pattern selected by convenience sampling method. A Vicon 470 system(Oxford Metrix, U.K. consisting of 6 cameras operating at 60Hz and kistler forceplate (A9286 was used.The paired samples T test was used to statistical analysis. Results: The results showed that there is no significant change in temporal-spatial parameters while wearing this modified shoe ,but the ankle moments while wearing rocker shoes in sagittal plane was significantly less than that while wearing traditional shoes(p=0.002 but in frontal plane significantly increased(p=0.007. Conclusion: Based on the current findings the major benefits of this modified shoe appear to be significantly restricted sagital plane moments with maintenance of walking speed so the loads on ankle joint and achilles tendon reduced, but increases frontal plain moments which leads to increase of mediolateral instability of ankle joint.

  14. The new Toyota variable valve timing and lift system

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, K.; Fuwa, N.; Yoshihara, Y. [Toyota Motor Corporation (Japan); Hori, K. [Toyota Boshoku Corporation (Japan)

    2007-07-01

    A continuously variable valve timing (duration and phase) and lift system was developed. This system was applied to the valvetrain of a new 2.0L L4 engine (3ZRFAE) for the Japanese market. The system has rocker arms, which allow continuously variable timing and lift, situated between a conventional roller-rocker arm and the camshaft, an electromotor actuator to drive it and a phase mechanism for intake and exhaust camshafts (Dual VVT-i). The rocking center of the rocker arm is stationary, and the axial linear motion of a helical spline changes the initial phase of the rocker arm which varies the timing and lift. The linear motion mechanism uses an original planetary roller screw and is driven by a brushless motor with a built-in electric control unit. Since the rocking center and the linear motion helical spline center coincide, a compact cylinder head design was possible, and the cylinder head is a common design with a conventional engine. Since the ECU controls intake valve duration and timing, a fuel economy gain of maximum 10% (depending on driving condition) is obtained by reducing light to medium load pumping losses. Also intake efficiency was maximized throughout the speed range, resulting in a power gain of 10%. Further, HC emissions were reduced due to increased air speed at low valve lift. (orig.)

  15. Analysis of Pivot Sampling in Dual-Pivot Quicksort

    DEFF Research Database (Denmark)

    Nebel, Markus E.; Wild, Sebastian; Martinez, Conrado

    2016-01-01

    The new dual-pivot Quicksort by Vladimir Yaroslavskiy—used in Oracle’s Java runtime library since version 7—features intriguing asymmetries. They make a basic variant of this algorithm use less comparisons than classic single-pivot Quicksort. In this paper, we extend the analysis to the case where...

  16. Electromotor control rod drive for nuclear reactors

    International Nuclear Information System (INIS)

    Baker, S.M.

    1975-01-01

    The positioning of a control rod arranged in a pressure vessel takes place with a drive. This protrudes out of the pressure vessel through a support and is formed from a rotating field motor with energy source, e.g. alternating current connection. Its stator surrounds a section of a pressure casing which covers the length of the drive. The rotor is arranged in the pressure casing and interacts with a shaft lying in the rotation axis. Furthermore, segments are hinged on it, each of which forms two arms of a rocker. Each segment can be revolved against a storing force in a plane containing the rotation axis, through the stator field acting on one of the rocker arms. In order that the drive motor is automatically blocked should the electricity supply fail, the other rocker arm can be connected with a fixed cased component of the drive having the effect of a friction break or a form-locking mechanical catch. (DG/LH) [de

  17. Analysis of hypothetical loss-of-control-arm accidents in HIFAR

    International Nuclear Information System (INIS)

    Connolly, J.W.; Clark, N.

    1986-11-01

    The reactor power transient produced in the HIFAR materials testing reactor upon severance of a central coarse control arm connecting rod and the subsequent pivoting of the arm out of the core has been calculated for a range of reactor conditions likely to be encountered in normal operation. It is concluded that as long as the remaining arms of the control arm bank can be relied on to suppress the post power peak oscillations in power, the reactor will withstand the consequences of such an accident

  18. Effectiveness of Foot Orthoses Versus Rocker-Sole Footwear for First Metatarsophalangeal Joint Osteoarthritis: Randomized Trial.

    Science.gov (United States)

    Menz, Hylton B; Auhl, Maria; Tan, Jade M; Levinger, Pazit; Roddy, Edward; Munteanu, Shannon E

    2016-05-01

    To compare the effectiveness of prefabricated foot orthoses to rocker-sole footwear in reducing foot pain in people with first metatarsophalangeal (MTP) joint osteoarthritis (OA). Participants (n = 102) with first MTP joint OA were randomly allocated to receive individualized, prefabricated foot orthoses or rocker-sole footwear. The primary outcome measure was the pain subscale on the Foot Health Status Questionnaire (FHSQ) at 12 weeks. Secondary outcome measures included the function, footwear, and general foot health subscales of the FHSQ; the Foot Function Index; severity of pain and stiffness at the first MTP joint; perception of global improvement; general health status; use of rescue medication and co-interventions to relieve pain; physical activity; and the frequency of self-reported adverse events. The FHSQ pain subscale scores improved in both groups, but no statistically significant difference between the groups was observed (adjusted mean difference 2.05 points, 95% confidence interval [95% CI] -3.61, 7.71; P = 0.477). However, the footwear group exhibited lower adherence (mean ± SD total hours worn 287 ± 193 versus 448 ± 234; P footwear are similarly effective at reducing foot pain in people with first MTP joint OA. However, prefabricated foot orthoses may be the intervention of choice due to greater adherence and fewer associated adverse events. © 2016 The Authors. Arthritis Care & Research published by Wiley Periodicals, Inc. on behalf of the American College of Rheumatology.

  19. Effect of Rocker Bar Ankle Foot Orthosis on Functional Mobility in Post-Stroke Hemiplegic Patients: Timed Up and Go and Gait Speed Assessments

    Directory of Open Access Journals (Sweden)

    Farzad Farmani

    2016-03-01

    Discussion: RAFO led to a significant improvement in functional mobility in hemiplegic patients post stroke. This may be due to the positive effect of rocker modification on improving push off and transferring weight during the stance phase of gait.

  20. Preset pivotal tool holder

    Science.gov (United States)

    Asmanes, Charles

    1979-01-01

    A tool fixture is provided for precise pre-alignment of a radiused edge cutting tool in a tool holder relative to a fixed reference pivot point established on said holder about which the tool holder may be selectively pivoted relative to the fixture base member to change the contact point of the tool cutting edge with a workpiece while maintaining the precise same tool cutting radius relative to the reference pivot point.

  1. Predictors of response to prefabricated foot orthoses or rocker-sole footwear in individuals with first metatarsophalangeal joint osteoarthritis

    OpenAIRE

    Menz, HB; Auhl, M; Tan, JM; Levinger, P; Roddy, E; Munteanu, SE

    2017-01-01

    BACKGROUND: Osteoarthritis of the first metatarsophalangeal joint (1st MTPJ OA) is a common and disabling condition commonly managed with footwear and orthotic interventions. The objective of this study was to identify factors associated with a successful treatment response in people with 1st MTPJ OA provided with prefabricated orthoses or rocker-sole footwear as part of a randomised clinical trial. METHODS: People with 1st MTPJ OA (n = 88) who participated in a randomised trial were allocate...

  2. Micromechanisms with floating pivot

    Science.gov (United States)

    Garcia, Ernest J.

    2001-03-06

    A new class of tilting micromechanical mechanisms have been developed. These new mechanisms use floating pivot structures to relieve some of the problems encountered in the use of solid flexible pivots.

  3. Evaluation of water distribution under pivot irrigation systems using remote sensing imagery in eastern Nile delta

    Directory of Open Access Journals (Sweden)

    E. Farg

    2017-04-01

    Full Text Available Traditional methods for center pivot evaluation depend on the water depth distribution along the pivot arm. Estimation and mapping the water depth under pivot irrigation systems using remote sensing data is essential for calculating the coefficient of uniformity (CU of water distribution. This study focuses on estimating and mapping water depth using Landsat OLI 8 satellite data integrated with Heerman and Hein (1968 modified equation for center pivot evaluation. Landsat OLI 8 image was geometrically and radiometrically corrected to calculate the vegetation and water indices (NDVI and NDWI in addition to land surface temperature. Results of the statistical analysis showed that the collected water depth in catchment cans is also highly correlated negatively with NDVI. On the other hand water, depth was positively correlated with NDWI and LST. Multi-linear regression analysis using stepwise selection method was applied to estimate and map the water depth distribution. The results showed R2 and adjusted R2 0.93 and 0.88 respectively. Study area or field level verification was applied for estimation equation with correlation 0.93 between the collected water depth and estimated values.

  4. Manual input device for controlling a robot arm

    International Nuclear Information System (INIS)

    Fischer, P.J.; Siva, K.V.

    1990-01-01

    A six-axis input device, eg joystick, is supported by a mechanism which enables the joystick to be aligned with any desired orientation, eg parallel to the tool. The mechanism can then be locked to provide a rigid support of the joystick. The mechanism may include three pivotal joints whose axes are perpendicular, each incorporating a clutch. The clutches may be electromagnetic or mechanical and may be operable jointly or independently. The robot arm comprises a base rotatable about a vertical axis, an upper arm, a forearm and a tool or grip rotatable about three perpendicular axes relative to the forearm. (author)

  5. Development of a methodology for the evaluation of energy efficiency of central irrigation pivots; Desenvolvimento de uma metodologia para a avaliacao da eficiencia energetica de pivos centrais de irrigacao

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Aureo Cezar de [Centro Federal de Educacao Tecnologica de Petrolina (CEFET-Pet), PE (Brazil); Guimaraes Junior, Sebastiao Camargo; Camacho, Jose Roberto; Salerno, Carlos Henrique [Universidade Federal de Uberlandia (NERFAE/UFU), MG (Brazil). Fac. de Engenharia Eletrica. Nucleo de Eletricidade Rural e Fontes Alternativas de Energia

    2006-07-01

    It will be presented in this work a methodology for the evaluation of the energy efficiency of irrigation center systems by central pivot. Integrating water efficiency application with the energy associated to the sprinklers, adduction pipeline, pivot arm and pump systems, the proposed indexes make possible to evaluate the energy income of each component of the irrigation system, contributing for the increase of the global efficiency of the irrigated agriculture. (author)

  6. How Good Is Multi-Pivot Quicksort?

    DEFF Research Database (Denmark)

    Aumüller, Martin; Dietzfelbinger, Martin; Klaue, Pascal

    2016-01-01

    of the partitioning cost is caused by rearranging elements. A rigorous analysis of an algorithm for rearranging elements in the partitioning step is carried out, observing mainly how often array cells are accessed during partitioning. The algorithm behaves best if three to five pivots are used. Experiments show...... that this translates into good cache behavior and is closest to predicting observed running times of multi-pivot quicksort algorithms. Finally, it is studied how choosing pivots from a sample affects sorting cost. The study is theoretical in the sense that although the findings motivate design recommendations...... as the standard sorting algorithm in Sun’s Java 7. In 2014 at ALENEX, Kushagra et al. introduced an even faster algorithm that uses three pivots. This article studies what possible advantages multi-pivot quicksort might offer in general. The contributions are as follows: Natural comparison-optimal algorithms...

  7. Extending Teach and Repeat to Pivoting Wheelchairs

    Directory of Open Access Journals (Sweden)

    Guillermo Del Castillo

    2003-02-01

    Full Text Available The paper extends the teach-and-repeat paradigm that has been successful for the control of holonomic robots to nonholonomic wheelchairs which may undergo pivoting action over the course of their taught movement. Due to the nonholonomic nature of the vehicle kinematics, estimation is required -- in the example given herein, based upon video detection of wall-mounted cues -- both in the teaching and the tracking events. In order to accommodate motion that approaches pivoting action as well as motion that approaches straight-line action, the estimation equations of the Extended Kalman Filter and the control equations are formulated using two different definitions of a nontemporal independent variable. The paper motivates the need for pivoting action in real-life settings by reporting extensively on the abilities and limitations of estimation-based teach-and-repeat action where pivoting and near-pivoting action is disallowed. Following formulation of the equations in the near-pivot mode, the paper reports upon experiments where taught trajectories which entail a seamless mix of near-straight and near-pivot action are tracked.

  8. The extended arm of health professionals?

    DEFF Research Database (Denmark)

    Norlyk, Annelise; Martinsen, Bente

    2013-01-01

    responsibility for both the patient's well-being and for the patient's compliance with the daily regimen. Relatives were caught in a conflicting double role. They were the extended arm of the health professionals but also the caring, supporting partner. A tension arose between relatives' desire to help....... Due to the early discharge and the increasing demands on patients for self-care, patients' relatives seem to play a pivotal role in fast-track programmes. However, research is limited into how patients' close relatives are affected by and involved in the postoperative recovery process. Design...

  9. Rocker-sole footwear versus prefabricated foot orthoses for the treatment of pain associated with first metatarsophalangeal joint osteoarthritis: study protocol for a randomised trial

    Science.gov (United States)

    2014-01-01

    Background Osteoarthritis affecting the first metatarsophalangeal joint of the foot is a common condition which results in pain, stiffness and impaired ambulation. Footwear modifications and foot orthoses are widely used in clinical practice to treat this condition, but their effectiveness has not been rigorously evaluated. This article describes the design of a randomised trial comparing the effectiveness of rocker-sole footwear and individualised prefabricated foot orthoses in reducing pain associated with first metatarsophalangeal joint osteoarthritis. Methods Eighty people with first metatarsophalangeal joint osteoarthritis will be randomly allocated to receive either a pair of rocker-sole shoes (MBT® Matwa, Masai Barefoot Technology, Switzerland) or a pair of individualised, prefabricated foot orthoses (Vasyli Customs, Vasyli Medical™, Queensland, Australia). At baseline, the biomechanical effects of the interventions will be examined using a wireless wearable sensor motion analysis system (LEGSys™, BioSensics, Boston, MA, USA) and an in-shoe plantar pressure system (Pedar®, Novel GmbH, Munich, Germany). The primary outcome measure will be the pain subscale of the Foot Health Status Questionnaire (FHSQ), measured at baseline and 4, 8 and 12 weeks. Secondary outcome measures will include the function, footwear and general foot health subscales of the FHSQ, severity of pain and stiffness at the first metatarsophalangeal joint (measured using 100 mm visual analog scales), global change in symptoms (using a 15-point Likert scale), health status (using the Short-Form-12® Version 2.0 questionnaire), use of rescue medication and co-interventions to relieve pain, the frequency and type of self-reported adverse events and physical activity levels (using the Incidental and Planned Activity Questionnaire). Data will be analysed using the intention to treat principle. Discussion This study is the first randomised trial to compare the effectiveness of rocker

  10. On nonlinear dynamics and control of a robotic arm with chaos

    Directory of Open Access Journals (Sweden)

    Felix J. L. P.

    2014-01-01

    Full Text Available In this paper a robotic arm is modelled by a double pendulum excited in its base by a DC motor of limited power via crank mechanism and elastic connector. In the mathematical model, a chaotic motion was identified, for a wide range of parameters. Controlling of the chaotic behaviour of the system, were implemented using, two control techniques, the nonlinear saturation control (NSC and the optimal linear feedback control (OLFC. The actuator and sensor of the device are allowed in the pivot and joints of the double pendulum. The nonlinear saturation control (NSC is based in the order second differential equations and its action in the pivot/joint of the robotic arm is through of quadratic nonlinearities feedback signals. The optimal linear feedback control (OLFC involves the application of two control signals, a nonlinear feedforward control to maintain the controlled system to a desired periodic orbit, and control a feedback control to bring the trajectory of the system to the desired orbit. Simulation results, including of uncertainties show the feasibility of the both methods, for chaos control of the considered system.

  11. Vertically loaded pivot bearing for high-speed shafts

    International Nuclear Information System (INIS)

    Zippe, G.; Werner, D.; Keller, A.; Stephan, E.

    1974-01-01

    The pivot bearing subjected to vertical loads has a pivot with a rounded end and a diametral slot and a cup-shaped recess in the bearing box. The end of the pivot and the recess constitute a gap which widens towards the periphery of the bearing. The bearing box carries an attachment with a clearance, the shape of a hollow cylinder and accomodating the pivot and its shaft. To feed the lubricating oil surrounding and filling the bearing there is a groove either in the wall of the clearance or at the end of the pivot in the direction of rotation of the shaft or against it. The oil carried to the support point flows back into the oil bath surrounding the bearing through a slot in the bearing box. (DG) [de

  12. A Virtual Pivot Point MEMS Actuator with Externally Mounted Mirror: Design, Fabrication and Characterization

    Directory of Open Access Journals (Sweden)

    T. M. Fahim AMIN

    2014-12-01

    Full Text Available In this paper, the design, fabrication, and characterization of a virtual pivot point micro electromechanical systems (MEMS electrostatic actuator with externally mounted mirror is presented. The point of rotation of the movable arm of the actuator is distant from the physical actuator. This is a requirement for certain applications, such as an external cavity laser in Littman configuration. A maximum rotational radius of 5 mm from the virtual pivot point was achieved. A detailed analytical analysis for the displacement of the structure is presented. The dynamic characterization of the device with a finite element analysis simulation shows that the resonance frequency of the in-plane rotational mode is well separated from that of the out-of-plane bending mode, confirming high in-plane stability. The devices were fabricated on a silicon-on-insulator wafer with device layer thickness of 100 µm. Thin mirrors were fabricated by dicing a 100 µm thick silicon wafer. A resonance frequency of about 5.9 ´ 102 Hz for the maximum sized mounted mirror (1.7 mm ´ 100 µm ´ 1.0 mm was determined by optical characterization.

  13. A new pivot system with hydromagnetic support

    International Nuclear Information System (INIS)

    Dauvergne, J.P.

    1980-02-01

    A type of pivot is described which acts as both a bearing and an end stop. The pivot avoids any mechanical contact between the moving and stationary parts, and operates with practically no friction and thus no wear. (orig.)

  14. Excel PivotTables and PivotCharts Your Visual Blueprint for Creating Dynamic Spreadsheets

    CERN Document Server

    McFedries, Paul

    2010-01-01

    Master two of the most powerful features of Excel. Even if you use Excel all the time, you may not be up to speed on two of Excel's most useful features. PivotTable and PivotChart turn long lists of unreadable data into dynamic, easy-to-read tables and charts that highlight the information you need most; you can tweak results with a click or easily fuse data from several sources into one document. Now you can learn how to tap these powerful Excel tools with this practical guide. Using a series of step-by-step tutorials and easy-to-follow screenshots, this book shows you in a visual way how to

  15. Assessment of the pivot shift using inertial sensors

    OpenAIRE

    Zaffagnini, Stefano; Signorelli, Cecilia; Grassi, Alberto; Yue, Han; Raggi, Federico; Urrizola, Francisco; Bonanzinga, Tommaso; Marcacci, Maurilio

    2016-01-01

    The pivot shift test is an important clinical tool used to assess the stability of the knee following an injury to the anterior cruciate ligament (ACL). Previous studies have shown that significant variability exists in the performance and interpretation of this manoeuvre. Accordingly, a variety of techniques aimed at standardizing and quantifying the pivot shift test have been developed. In recent years, inertial sensors have been used to measure the kinematics of the pivot shift. The goal o...

  16. PowerPivot for Business Intelligence Using Excel and SharePoint

    CERN Document Server

    Ralston, Barry

    2011-01-01

    PowerPivot comprises a set of technologies for easy access to data mining and business intelligence analysis from Microsoft Excel and SharePoint. Power users and developers alike can create sophisticated, online analytic processing (OLAP) solutions using PowerPivot for Excel, and then share those solutions with other users via PowerPivot for SharePoint. Data can be pulled in from any of the leading database platforms, as well as from spreadsheets and flat files. PowerPivot for Business Intelligence Using Excel and SharePoint is your key to mastering PowerPivot. The book takes a scenario-based

  17. Objective Metric Based Assessments for Efficient Evaluation of Auditory Situation Awareness Characteristics of Tactical Communications and Protective Systems (TCAPS) and Augmented Hearing Protective Devices (HPDs)

    Science.gov (United States)

    2015-11-30

    rocker -style, single-ended) earplug...X50_unity_ ComTac_III_max_ Combat_Arms_open EB15LE_max_ dB 125 Hz, Speaker at 9 open ear A AB ABC BCD BCD CDE DE DE E -1 1 3 5 7 9...Speaker at 9 open ear A B BC BCD BCD BCD CDE DE E -8 -6 -4 -2 0 2 4 Combat_Arms_open QuietPro_unity_ X50_unity_

  18. Subexponential lower bounds for randomized pivoting rules for the simplex algorithm

    DEFF Research Database (Denmark)

    Friedmann, Oliver; Hansen, Thomas Dueholm; Zwick, Uri

    2011-01-01

    The simplex algorithm is among the most widely used algorithms for solving linear programs in practice. With essentially all deterministic pivoting rules it is known, however, to require an exponential number of steps to solve some linear programs. No non-polynomial lower bounds were known, prior...... to this work, for randomized pivoting rules. We provide the first subexponential (i.e., of the form 2Ω(nα), for some α>0) lower bounds for the two most natural, and most studied, randomized pivoting rules suggested to date. The first randomized pivoting rule considered is Random-Edge, which among all improving...... pivoting steps (or edges) from the current basic feasible solution (or vertex) chooses one uniformly at random. The second randomized pivoting rule considered is Random-Facet, a more complicated randomized pivoting rule suggested by Kalai and by Matousek, Sharir and Welzl. Our lower bound for the Random...

  19. Compound floating pivot micromechanisms

    Science.gov (United States)

    Garcia, Ernest J.

    2001-04-24

    A new class of tilting micromechanical mechanisms have been developed. These new mechanisms use compound floating pivot structures to attain far greater tilt angles than are practical using other micromechanical techniques. The new mechanisms are also capable of bi-directional tilt about multiple axes.

  20. WASP (Write a Scientific Paper) using Excel - 2: Pivot tables.

    Science.gov (United States)

    Grech, Victor

    2018-02-01

    Data analysis at the descriptive stage and the eventual presentation of results requires the tabulation and summarisation of data. This exercise should always precede inferential statistics. Pivot tables and pivot charts are one of Excel's most powerful and underutilised features, with tabulation functions that immensely facilitate descriptive statistics. Pivot tables permit users to dynamically summarise and cross-tabulate data, create tables in several dimensions, offer a range of summary statistics and can be modified interactively with instant outputs. Large and detailed datasets are thereby easily manipulated making pivot tables arguably the best way to explore, summarise and present data from many different angles. This second paper in the WASP series in Early Human Development provides pointers for pivot table manipulation in Excel™. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Sparsity Prevention Pivoting Method for Linear Programming

    DEFF Research Database (Denmark)

    Li, Peiqiang; Li, Qiyuan; Li, Canbing

    2018-01-01

    When the simplex algorithm is used to calculate a linear programming problem, if the matrix is a sparse matrix, it will be possible to lead to many zero-length calculation steps, and even iterative cycle will appear. To deal with the problem, a new pivoting method is proposed in this paper....... The principle of this method is avoided choosing the row which the value of the element in the b vector is zero as the row of the pivot element to make the matrix in linear programming density and ensure that most subsequent steps will improve the value of the objective function. One step following...... this principle is inserted to reselect the pivot element in the existing linear programming algorithm. Both the conditions for inserting this step and the maximum number of allowed insertion steps are determined. In the case study, taking several numbers of linear programming problems as examples, the results...

  2. Sparsity Prevention Pivoting Method for Linear Programming

    DEFF Research Database (Denmark)

    Li, Peiqiang; Li, Qiyuan; Li, Canbing

    2018-01-01

    . The principle of this method is avoided choosing the row which the value of the element in the b vector is zero as the row of the pivot element to make the matrix in linear programming density and ensure that most subsequent steps will improve the value of the objective function. One step following......When the simplex algorithm is used to calculate a linear programming problem, if the matrix is a sparse matrix, it will be possible to lead to many zero-length calculation steps, and even iterative cycle will appear. To deal with the problem, a new pivoting method is proposed in this paper...... this principle is inserted to reselect the pivot element in the existing linear programming algorithm. Both the conditions for inserting this step and the maximum number of allowed insertion steps are determined. In the case study, taking several numbers of linear programming problems as examples, the results...

  3. Multimedia Pivot Tables for Multimedia Analytics on Image Collections

    NARCIS (Netherlands)

    Worring, M.; Koelma, D.; Zahálka, J.

    2016-01-01

    We propose a multimedia analytics solution for getting insight into image collections by extending the powerful analytic capabilities of pivot tables, found in the ubiquitous spreadsheets, to multimedia. We formalize the concept of multimedia pivot tables and give design rules and methods for the

  4. New variants of finite criss-cross pivot algorithms for linear programming

    NARCIS (Netherlands)

    S. Zhang (Shuzhong)

    1997-01-01

    textabstractIn this paper we generalize the so-called first-in-last-out pivot rule and the most-often-selected-variable pivot rule for the simplex method, as proposed in Zhang \\\\cite{Z91}, to the criss-cross pivot setting where neither the primal nor the dual feasibility is preserved. The finiteness

  5. PowerPivot for advanced reporting and dashboards

    CERN Document Server

    Bosco, Robert

    2013-01-01

    A step-by-step tutorial with focused examples that builds progressively from basic to advanced topics and helps you create business intelligence reports and dashboards quickly and efficiently using the PowerPivot add-in.This book is ideal for data analysts, reporting and MIS professionals, business analysts, managers, dashboard makers, business intelligence professionals, self-service business intelligence personnel, and students. It is assumed that you have basic data analysis skills and intermediate level Excel skills. Familiarity with Pivot Tables as well as basic knowledge of VBA scripting

  6. Flexural pivot device

    International Nuclear Information System (INIS)

    Flaherty, Robert.

    1986-01-01

    A flexural pivot device or rotational actuator comprises first and sceond tubular members connected by flexural members of shape-memory-alloy. These are curved in the austenitic phase at a first temperature and after cooling to the martensitic phase are flattened. On heating one of the flexural members, it bends causing relative rotation of the tubular members. Heating of another member can produce opposite rotation. Heating is electrical or by hot gas. The device may be used in a nuclear reactor. (author)

  7. Modified rib pivot lateral thoracotomy: a case series.

    Science.gov (United States)

    Appelgrein, C; Hosgood, G

    2018-01-01

    To describe a modified rib pivot thoracotomy and its clinical application in client-owned dogs and cats. Case series of 24 dogs and 1 cat requiring a thoracotomy. A lateral thoracic incision over the required thoracic segment was made. The latissimus dorsi muscle was reflected dorsally. The predetermined rib was identified and the periosteum overlying the rib was elevated circumferentially, avoiding the intercostal neurovascular structures. Holes were pre-placed above and below the proposed osteotomy site. The rib was osteotomised and pivoted cranially. The pleura was incised and the required intrathoracic procedure was then performed. The thoracic cavity was closed by pre-placement of a suture through the pre-placed holes within the osteotomised rib. The pleura and intercostal musculature were closed, avoiding the intercostal neurovascular structures. The rib was re-apposed and the lateral approach was closed. The cases included were reviewed for both the rib pivoted as per the procedure required and postoperative complications. The study group comprised 8 Staffordshire Bull Terriers, 2 Poodles, 2 German Shepherd Dogs, 1 each of Basset Hound, Rhodesian Ridgeback, Golden Retriever, Australian Shepherd, Vizsla, Bull Mastiff, Schnauzer, Jack Russell Terrier, Bulldog, Deerhound, Labrador Retriever and Australian Terrier, and 1 cat. A modified rib pivot thoracotomy was performed for lung lobectomy (n = 11), oesophagectomy (7), subtotal pericardectomy (5), patent ductus arteriosus ligation (1) and thoracic duct ligation (1). Follow-up ranged from 2 to 40 weeks postoperatively. Postoperative complications included seroma formation in two dogs. A modified rib pivot thoracotomy should be considered as an alternative lateral thoracic approach with good exposure, minimal complications and low morbidity. © 2018 Australian Veterinary Association.

  8. 'Pivotal politics' in US energy and climate legislation

    International Nuclear Information System (INIS)

    Skodvin, Tora

    2010-01-01

    In the 110th Congress (2007-2008) legislation related to climate change was introduced at a faster pace than in any previous Congress, yet it did not result in a corresponding increase in enacted climate-related laws. A pertinent example of the political infeasibility of climate policy change in the 110th Congress is the case of tax credit extensions for production of renewable energy. While this issue in itself was uncontroversial, the extensions were only adopted in the 11th hour, after innumerable failed attempts. With an analytical point of departure in Krehbiel's theory of pivotal politics, this paper seeks to identify pivotal legislators in the case of the tax credit extensions and discusses how changes in the composition of pivotal legislators in the 111th Congress (2009-2010) may impact the prospects of moving climate legislation more generally. The analysis indicates that a majority of the legislative pivots in the case of tax credit extensions were Republican senators representing coal-producing states. In the case of climate change, however, the regional dimension is likely to be more significant for Democratic voting behaviour. Thus, the opportunity space for climate legislation in the 111th Congress remains narrow even with a reinforced Democratic majority in Congress.

  9. Failures to be celebrated: an analysis of major pivots of software startups

    OpenAIRE

    Bajwa, Sohaib Shahid; Wang, Xiaofeng; Duc, Anh Nguyen; Abrahamsson, Pekka

    2017-01-01

    In the context of software startups, project failure is embraced actively and considered crucial to obtain validated learning that can lead to pivots. A pivot is the strategic change of a business concept, product or the different elements of a business model. A better understanding is needed on different types of pivots and different factors that lead to failures and trigger pivots, for software entrepreneurial teams to make better decisions under chaotic and unpredictable environment. Due t...

  10. Understanding Rasch Measurement: Partial Credit Model and Pivot Anchoring.

    Science.gov (United States)

    Bode, Rita K.

    2001-01-01

    Describes the Rasch measurement partial credit model, what it is, how it differs from other Rasch models, and when and how to use it. Also describes the calibration of instruments with increasingly complex items. Explains pivot anchoring and illustrates its use and describes the effect of pivot anchoring on step calibrations, item hierarchy, and…

  11. HPC s Pivot to Data

    Energy Technology Data Exchange (ETDEWEB)

    Parete-Koon, Suzanne [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Oak Ridge Leadership Computing Facility (OLCF); Caldwell, Blake A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Oak Ridge Leadership Computing Facility (OLCF); Canon, Richard Shane [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). National Energy Research Scientific Computing Center (NERSC); Dart, Eli [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Sciences Network (ESnet); Hick, Jason [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). National Energy Research Scientific Computing Center (NERSC); Hill, Jason J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Oak Ridge Leadership Computing Facility (OLCF); Layton, Chris [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Oak Ridge Leadership Computing Facility (OLCF); Pelfrey, Daniel S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Oak Ridge Leadership Computing Facility (OLCF); Shipman, Galen M [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Oak Ridge Leadership Computing Facility (OLCF); Skinner, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). National Energy Research Scientific Computing Center (NERSC); Nam, Hai Ah [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Oak Ridge Leadership Computing Facility (OLCF); Wells, Jack C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Oak Ridge Leadership Computing Facility (OLCF); Zurawski, Jason [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Sciences Network (ESnet)

    2014-05-03

    Computer centers such as NERSC and OLCF have traditionally focused on delivering computational capability that enables breakthrough innovation in a wide range of science domains. Accessing that computational power has required services and tools to move the data from input and output to computation and storage. A ''pivot to data'' is occurring in HPC. Data transfer tools and services that were previously peripheral are becoming integral to scientific workflows. Emerging requirements from high-bandwidth detectors, high-throughput screening techniques, highly concur- rent simulations, increased focus on uncertainty quantification, and an emerging open-data policy posture toward published research are among the data-drivers shaping the networks, file systems, databases, and overall compute and data environment. In this paper we explain the pivot to data in HPC through user requirements and the changing resources provided by HPC with particular focus on data movement. For WAN data transfers we present the results of a study of network performance between centers.

  12. Failure Analysis on Tail Rotor Teeter Pivot Bolt on a Helicopter

    Science.gov (United States)

    Qiang, WANG; Zi-long, DONG

    2018-03-01

    Tail rotor teeter pivot bolt of a helicopter fractured when in one flight. Failure analysis on the bolt was finished in laboratory. Macroscopic observation of the tailor rotor teeter pivot bolt, macro and microscopic inspection on the fracture surface of the bolt was carried out. Chemical components and metallurgical structure was also carried out. Experiment results showed that fracture mode of the tail rotor teeter pivot bolt is fatigue fracture. Fatigue area is over 80% of the total fracture surface, obvious fatigue band characteristics can be found at the fracture face. According to the results were analyzed from the macroscopic and microcosmic aspects, fracture reasons of the tail rotor teeter pivot bolt were analyzed in detail

  13. Investigation on hard coating of pivot-jewel bearing and wearing performance

    International Nuclear Information System (INIS)

    Han Kun; Dai Xingjian

    2014-01-01

    The reliability of high speed rotating machine is related to the anti-wear properties of pivot jewel bearing used in the system. To reduce its wearing process, hard coating method is used on the steel pivot. Through the wearing test on specialized facilities, its founded that the TiN coating shows better performance than DLC coating, and multi-layer TiN coating can slow down the pivot's wearing process obviously compared to other methods. (authors)

  14. Multimedia Pivot Tables for Multimedia Analytics on Image Collections

    OpenAIRE

    Worring, M.; Koelma, D.; Zahálka, J.

    2016-01-01

    We propose a multimedia analytics solution for getting insight into image collections by extending the powerful analytic capabilities of pivot tables, found in the ubiquitous spreadsheets, to multimedia. We formalize the concept of multimedia pivot tables and give design rules and methods for the multimodal summarization, structuring, and browsing of the collection based on these tables, all optimized to support an analyst in getting structural and conclusive insights. Our proposed solution p...

  15. PIVOT: platform for interactive analysis and visualization of transcriptomics data.

    Science.gov (United States)

    Zhu, Qin; Fisher, Stephen A; Dueck, Hannah; Middleton, Sarah; Khaladkar, Mugdha; Kim, Junhyong

    2018-01-05

    Many R packages have been developed for transcriptome analysis but their use often requires familiarity with R and integrating results of different packages requires scripts to wrangle the datatypes. Furthermore, exploratory data analyses often generate multiple derived datasets such as data subsets or data transformations, which can be difficult to track. Here we present PIVOT, an R-based platform that wraps open source transcriptome analysis packages with a uniform user interface and graphical data management that allows non-programmers to interactively explore transcriptomics data. PIVOT supports more than 40 popular open source packages for transcriptome analysis and provides an extensive set of tools for statistical data manipulations. A graph-based visual interface is used to represent the links between derived datasets, allowing easy tracking of data versions. PIVOT further supports automatic report generation, publication-quality plots, and program/data state saving, such that all analysis can be saved, shared and reproduced. PIVOT will allow researchers with broad background to easily access sophisticated transcriptome analysis tools and interactively explore transcriptome datasets.

  16. Mechanical design of deformation compensated flexural pivots structured for linear nanopositioning stages

    Science.gov (United States)

    Shu, Deming; Kearney, Steven P.; Preissner, Curt A.

    2015-02-17

    A method and deformation compensated flexural pivots structured for precision linear nanopositioning stages are provided. A deformation-compensated flexural linear guiding mechanism includes a basic parallel mechanism including a U-shaped member and a pair of parallel bars linked to respective pairs of I-link bars and each of the I-bars coupled by a respective pair of flexural pivots. The basic parallel mechanism includes substantially evenly distributed flexural pivots minimizing center shift dynamic errors.

  17. The influence of applied internal and external rotation on the pivot shift phenomenon.

    Science.gov (United States)

    Kopf, Sebastian; Musahl, Volker; Perka, Carsten; Kauert, Ralf; Hoburg, Arnd; Becker, Roland

    2017-04-01

    The pivot shift test is performed in different techniques and the rotation of the tibia seems to have a significant impact on the amount of the pivot shift phenomenon. It has been hypothesised that external rotation will increase the phenomenon due to less tension at the iliotibial band in knee extension. Twenty-four patients with unilateral anterior cruciate ligament insufficiency were included prospectively. The pivot shift test was performed bilaterally in internal and external tibial rotation under general anaesthesia. Knee motion was captured using a femoral and a tibial inertial sensor. The difference between positive and negative peak values in Euclidean norm of acceleration was calculated to evaluate the amount of the pivot shift phenomenon. The pivot shift phenomenon was significantly increased in patients with ACL insufficiency when the test was performed in external [mean 5.2 ms - 2 (95% CI 4.3-6.0)] compared to internal tibial rotation [mean 4.4 ms - 2 (95% CI 3.5-5.4)] (p = 0.002). In healthy, contralateral knees did not show any difference between external [mean 4.0 ms - 2 (95% CI 3.3-4.7)] and internal tibial rotation [mean 4.0 ms - 2 (95% CI 3.4-4.6)] (ns). The pivot shift phenomenon was increased with external rotation in ACL-insufficient knees, and therefore, one should perform the pivot shift test, rather, in external rotation to easily evoke the, sometimes difficult to detect, pivot shift phenomenon. I (diagnostic study).

  18. Causes of death from the randomized CoreValve US Pivotal High-Risk Trial.

    Science.gov (United States)

    Gaudiani, Vincent; Deeb, G Michael; Popma, Jeffrey J; Adams, David H; Gleason, Thomas G; Conte, John V; Zorn, George L; Hermiller, James B; Chetcuti, Stan; Mumtaz, Mubashir; Yakubov, Steven J; Kleiman, Neal S; Huang, Jian; Reardon, Michael J

    2017-06-01

    Explore causes and timing of death from the CoreValve US Pivotal High-Risk Trial. An independent clinical events committee adjudicated causes of death, followed by post hoc hierarchical classification. Baseline characteristics, early outcomes, and causes of death were evaluated for 3 time periods (selected based on threshold of surgical 30-day mortality and on the differences in the continuous hazard between the 2 groups): early (0-30 days), recovery (31-120 days), and late (121-365 days). Differences in the rate of death were evident only during the recovery period (31-120 days), whereas 15 patients undergoing transcatheter aortic valve replacement (TAVR) (4.0%) and 27 surgical aortic valve replacement (SAVR) patients (7.9%) died (P = .025). This mortality difference was largely driven by higher rates of technical failure, surgical complications, and lack of recovery following surgery. From 0 to 30 days, the causes of death were more technical failures in the TAVR group and lack of recovery in the SAVR group. Mortality in the late period (121-365 days) in both arms was most commonly ascribed to other circumstances, comprising death from medical complications from comorbid disease. Mortality at 1 year in the CoreValve US Pivotal High-Risk Trial favored TAVR over SAVR. The major contributor was that more SAVR patients died during the recovery period (31-121 days), likely affected by the overall influence of physical stress associated with surgery. Similar rates of technical failure and complications were observed between the 2 groups. This suggests that early TAVR results can improve with technical refinements and that high-risk surgical patients will benefit from reducing complications. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  19. Problem of unstable pivots in the incomplete LU-conjugate gradient method

    International Nuclear Information System (INIS)

    Kershaw, D.S.

    1978-01-01

    Incomplete LU and incomplete-Cholesky conjugate gradient methods are becoming widely used in both laser and magnetic fusion research. In my original presentation of these methods, the problem of what to do if a pivot [L/sub ii/U/sub ii/) becomes very small or zero was raised and only partially answered by the suggestion that it be arbitrarily set to some non-zero value. In what follows it will be shown precisely how small the pivot can become before it must be fixed and precisely what value it should be set to in order to minimize the error in LU. Numerical examples will be given to show that not only does this prescription improve incomplete LU-conjugate gradient methods , but exact LU decomposition carried out with this prescription for handling small pivots and followed by a few linear or conjugate gradient iterations can be much faster than the permutations of rows and columns usually employed to circumvent small pivot problems

  20. The beneficial effect of a speaker's gestures on the listener's memory for action phrases: The pivotal role of the listener's premotor cortex.

    Science.gov (United States)

    Ianì, Francesco; Burin, Dalila; Salatino, Adriana; Pia, Lorenzo; Ricci, Raffaella; Bucciarelli, Monica

    2018-04-10

    Memory for action phrases improves in the listeners when the speaker accompanies them with gestures compared to when the speaker stays still. Since behavioral studies revealed a pivotal role of the listeners' motor system, we aimed to disentangle the role of primary motor and premotor cortices. Participants had to recall phrases uttered by a speaker in two conditions: in the gesture condition, the speaker performed gestures congruent with the action; in the no-gesture condition, the speaker stayed still. In Experiment 1, half of the participants underwent inhibitory rTMS over the hand/arm region of the left premotor cortex (PMC) and the other half over the hand/arm region of the left primary motor cortex (M1). The enactment effect disappeared only following rTMS over PMC. In Experiment 2, we detected the usual enactment effect after rTMS over vertex, thereby excluding possible nonspecific rTMS effects. These findings suggest that the information encoded in the premotor cortex is a crucial part of the memory trace. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Method and system for dual resolution translation stage

    Science.gov (United States)

    Halpin, John Michael

    2014-04-22

    A dual resolution translation stage includes a stage assembly operable to receive an optical element and a low resolution adjustment device mechanically coupled to the stage assembly. The dual resolution stage also includes an adjustable pivot block mechanically coupled to the stage assembly. The adjustable pivot block includes a pivot shaft. The dual resolution stage further includes a lever arm mechanically coupled to the adjustable pivot block. The lever arm is operable to pivot about the pivot shaft. The dual resolution stage additionally includes a high resolution adjustment device mechanically coupled to the lever arm and the stage assembly.

  2. Bucket drill

    Energy Technology Data Exchange (ETDEWEB)

    Bezverkhiy, V.M.; Nabokov, I.M.; Podoksik, D.Z.; Sadovskiy, S.S.; Shanyukevich, V.A.

    1983-01-01

    The bucket drill including a cylindrical housing with bottom, ground intake windows and cutting knives is hinged to the housing, the mechanism of rotation of the cutting knives including rods connected by the cutter knives, and drive shaft is distinguished by the fact that in order to improve the effectiveness of drilling by automatic change in the angle of cutting depending on the strength of the drillable rock, the drill is equipped with elastic elements and cap with annular slits in which there are elastic elements. The mechanism of rotation of the cutting knives is equipped with levers hinged to the housing, pins with shaft and rocker arm. The rods are made with a slit and from one end are rigidly connected to the cutting knives, and from the other end to the levers by means of pins which are arranged in slits of the rod with the possibility of movement. The upper ends of the levers are installed with the possibility of movement in the pins whose shafts are arranged with the possibility of rotation in the rocker arm rigidly connected to the drive shaft. The drive shaft is equipped with cantilevers installed in the cap with the possibility of rotation and interaction with the elastic elements.

  3. Max-out-in pivot rule with Dantzig's safeguarding rule for the simplex method

    International Nuclear Information System (INIS)

    Tipawanna, Monsicha; Sinapiromsaran, Krung

    2014-01-01

    The simplex method is used to solve linear programming problem by improving the current basic feasible solution. It uses a pivot rule to guide the search in the feasible region. The pivot rule is used to select an entering index in simplex method. Nowadays, many pivot rule have been presented, but no pivot rule shows superior performance than other. Therefore, this is still an active research in linear programming. In this research, we present the max-out-in pivot rule with Dantzig's safeguarding for simplex method. This rule is based on maximum improvement of objective value of the current basic feasible point similar to the Dantzig's rule. We can illustrate by Klee and Minty problems that our rule outperforms that of Dantzig's rule by the number of iterations for solving linear programming problems

  4. Pivotal behavior as the mediator of the relationship between parental responsiveness and children's symbolic behavior.

    Science.gov (United States)

    Chiu, Chun-Hao; Lin, Chu-Sui; Mahoney, Gerald; Cheng, Shu-Fen; Chang, Shu-Hui

    2017-08-01

    Previous research with parents and children with developmental disabilities indicated that the relationship between mothers' responsive style of interaction and children's rate of development was mediated by the simultaneous relationship between mothers' responsiveness and children's social engagement, or pivotal behavior. In this study, we attempted to determine whether children's pivotal behavior might also mediate the relationship between responsiveness and child development in a sample of 165 typically developing toddlers and their Taiwanese parents. Child development was assessed with a parent report measure of children's symbolic behavior. Parental responsiveness and children's pivotal behavior were assessed from observations of parent-child play. Results indicated that parental responsiveness was correlated with children's pivotal behavior, and that both of these variables were correlated with children's symbolic behavior. Structural equation models indicated that the relationship between responsiveness and children's symbolic behavior was fully mediated by children's pivotal behavior. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Electrical servo actuator bracket. [fuel control valves on jet engines

    Science.gov (United States)

    Sawyer, R. V. (Inventor)

    1981-01-01

    An electrical servo actuator is mounted on a support arm which is allowed to pivot on a bolt through a fixed mounting bracket. The actuator is pivotally connected to the end of the support arm by a bolt which has an extension allowed to pass through a slot in the fixed mounting bracket. An actuator rod extends from the servo actuator to a crank arm which turns a control shaft. A short linear thrust of the rod pivots the crank arm through about 90 for full-on control with the rod contracted into the servo actuator, and full-off control when the rod is extended from the actuator. A spring moves the servo actuator and actuator rod toward the control crank arm once the actuator rod is fully extended in the full-off position. This assures the turning of the control shaft to a full-off position. A stop bolt and slot are provided to limit pivot motion. Once fully extended, the spring pivots the motion.

  6. Single-sided natural ventilation through a centre-pivot roof window

    DEFF Research Database (Denmark)

    Iqbal, Ahsan; Nielsen, Peter V.; Gunner, Amalie

    2014-01-01

    The characteristics of centre pivot roof windows for wind driven single-sided ventilation has not been studied before. These types of windows are dominating roof windows in Europe. Knowledge of flow characteristics of this kind of window is essential for accurate designing of natural ventilation...... systems. In this study, numerical methods were used to characterise a centre-pivot roof window for wind-driven single-sided ventilation. A 1:20 scale model house of the Energy Flex House (Denmark) was used in this study. The roof slope was 36o. It was found that the single-sided ventilation through...

  7. Plant responses, climate pivot points, and trade-offs in water-limited ecosystems

    Science.gov (United States)

    Munson, S. M.; Bunting, E.

    2017-12-01

    Ecosystem transitions and thresholds are conceptually well-defined and have become a framework to address vegetation response to climate change and land-use intensification, yet there are few approaches to define the environmental conditions which can lead to them. We demonstrate a novel climate pivot point approach using long-term monitoring data from a broad network of permanent plots, satellite imagery, and experimental treatments across the southwestern U.S. The climate pivot point identifies conditions that lead to decreased plant performance and serves as an early warning sign of increased vulnerability of crossing a threshold into an altered ecosystem state. Plant responses and climate pivot points aligned with the lifespan and structural characteristics of species, were modified by soil and landscape attributes of a site, and had non-linear dynamics in some cases. Species with strong increases in abundance when water was available were most susceptible to losses during water shortages, reinforcing plant energetic and physiological tradeoffs. Future research to uncover the heterogeneity of plant responses and climate pivot points at multiple scales can lead to greater understanding of shifts in ecosystem productivity and vulnerability to climate change.

  8. Stress optimization of leaf-spring crossed flexure pivots for an active Gurney flap mechanism

    Science.gov (United States)

    Freire Gómez, Jon; Booker, Julian D.; Mellor, Phil H.

    2015-04-01

    The EU's Green Rotorcraft programme is pursuing the development of a functional and airworthy Active Gurney Flap (AGF) for a full-scale helicopter rotor blade. Interest in the development of this `smart adaptive rotor blade' technology lies in its potential to provide a number of aerodynamic benefits, which would in turn translate into a reduction in fuel consumption and noise levels. The AGF mechanism selected employs leaf-spring crossed flexure pivots. These provide important advantages over bearings as they are not susceptible to seizing and do not require maintenance (i.e. lubrication or cleaning). A baseline design of this mechanism was successfully tested both in a fatigue rig and in a 2D wind tunnel environment at flight-representative deployment schedules. For full validation, a flight test would also be required. However, the severity of the in-flight loading conditions would likely compromise the mechanical integrity of the pivots' leaf-springs in their current form. This paper investigates the scope for stress reduction through three-dimensional shape optimization of the leaf-springs of a generic crossed flexure pivot. To this end, a procedure combining a linear strain energy formulation, a parametric leaf-spring profile definition and a series of optimization algorithms is employed. The resulting optimized leaf-springs are proven to be not only independent of the angular rotation at which the pivot operates, but also linearly scalable to leaf-springs of any length, minimum thickness and width. Validated using non-linear finite element analysis, the results show very significant stress reductions relative to pivots with constant cross section leaf-springs, of up to as much as 30% for the specific pivot configuration employed in the AGF mechanism. It is concluded that shape optimization offers great potential for reducing stress in crossed flexure pivots and, consequently, for extending their fatigue life and/or rotational range.

  9. Quantitative evaluation of the pivot shift by image analysis using the iPad.

    Science.gov (United States)

    Hoshino, Yuichi; Araujo, Paulo; Ahldén, Mattias; Samuelsson, Kristian; Muller, Bart; Hofbauer, Marcus; Wolf, Megan R; Irrgang, James J; Fu, Freddie H; Musahl, Volker

    2013-04-01

    To enable comparison of test results, a widely available measurement system for the pivot shift test is needed. Simple image analysis of lateral knee joint translation is one such system that can be installed on a prevalent computer tablet (e.g. iPad). The purpose of this study was to test a novel iPad application to detect the pivot shift. It was hypothesized that the abnormal lateral translation in ACL deficient knees would be detected by the iPad application. Thirty-four consecutive ACL deficient patients were tested. Three skin markers were attached on the following bony landmarks: (1) Gerdy's tubercle, (2) fibular head and (3) lateral epicondyle. A standardized pivot shift test was performed under anaesthesia, while the lateral side of the knee joint was monitored. The recorded movie was processed by the iPad application to measure the lateral translation of the knee joint. Lateral translation was compared between knees with different pivot shift grades. Valid data sets were obtained in 20 (59 %) ACL deficient knees. The remaining 14 data sets were invalid because of failure to detect translation or detection of excessive translation. ACL deficient knees had larger lateral translation than the contra-lateral knees (p iPad application, the potential of the iPad application to classify the pivot shift was demonstrated.

  10. Classroom Pivotal Response Teaching for Children with Autism

    Science.gov (United States)

    Stahmer, Aubyn C.; Suhrheinrich, Jessica; Reed, Sarah; Schreibman, Laura; Bolduc, Cynthia

    2011-01-01

    This practical manual and accompanying DVD-ROM present a research-supported behavioral intervention for children with autism that teachers can easily integrate into their existing classroom curriculum. Classroom Pivotal Response Teaching (CPRT) enhances children's motivation and participation in learning; increases the number of learning…

  11. Proprioceptive Interaction between the Two Arms in a Single-Arm Pointing Task.

    Directory of Open Access Journals (Sweden)

    Kazuyoshi Kigawa

    Full Text Available Proprioceptive signals coming from both arms are used to determine the perceived position of one arm in a two-arm matching task. Here, we examined whether the perceived position of one arm is affected by proprioceptive signals from the other arm in a one-arm pointing task in which participants specified the perceived position of an unseen reference arm with an indicator paddle. Both arms were hidden from the participant's view throughout the study. In Experiment 1, with both arms placed in front of the body, the participants received 70-80 Hz vibration to the elbow flexors of the reference arm (= right arm to induce the illusion of elbow extension. This extension illusion was compared with that when the left arm elbow flexors were vibrated or not. The degree of the vibration-induced extension illusion of the right arm was reduced in the presence of left arm vibration. In Experiment 2, we found that this kinesthetic interaction between the two arms did not occur when the left arm was vibrated in an abducted position. In Experiment 3, the vibration-induced extension illusion of one arm was fully developed when this arm was placed at an abducted position, indicating that the brain receives increased proprioceptive input from a vibrated arm even if the arm was abducted. Our results suggest that proprioceptive interaction between the two arms occurs in a one-arm pointing task when the two arms are aligned with one another. The position sense of one arm measured using a pointer appears to include the influences of incoming information from the other arm when both arms were placed in front of the body and parallel to one another.

  12. Developing a Simple Unique Head-Discharge Equation for Pivot Weirs with Different Side Contractions

    Directory of Open Access Journals (Sweden)

    neda Sheikh Rezazadeh Nikou

    2016-10-01

    Full Text Available Introduction: Pivot weirs (sharp crested inclined weirs, Fig. 1-a is frequently used for discharge measurement, controlling water surface and flow diversion. Some typical features of pivot weirs are: (a overshot design for better water level control, (b Their application as head gates, turnout or check structure which requiring low head loss and high accuracy, (c ease of removing sediment deposit behind the weir, and (d ability to manage and monitor on-site or operating remotely when connected to a supervisory control and data acquisition (SCADA network. Kindsvater and Carter (8 derived a weir discharge equation based on energy and continuity equations. Hulsing (4 determined head-discharge relationship of inclined suppressed sharp crested weir with the slope of 3:3, 2:3 and 1:3 toward downstream and compared them with the equivalent normal sharp crested weir. In the USBR report on pivot weirs (regarding The Boulder Canyon Project,1948 the head discharge data of the suppressed pivot weir were presented in a channel with 5.5m length, 2.9m depth and 0.61m width. Some field experiments were also carried out in the IID (Imperial Irrigation District on a trapezoidal cross-section (0.61 m bottom width channel with pivot weir of 1.7m length, and two different widths of 1.63m. The flow rate (350-880 lit/s was held constant and different angles (15-50° calibrated instead of holding the angle constant and varying the flow rate. Some other laboratory tests were performed with Wahlin and Replogle (1994 on two pivot weirs with 1.2 m and 1.14 m width for the 0.61 m and 0.46 m length of blade and contraction factor of 0.925. RUBICON Company established an extensive operation on the application and automation of pivot weirs in irrigation channels in Australia (Www.rubicon.com. All previous studies concentrated on modifying the normal rectangular weir head-discharge equation so that it can be used for the pivot weirs. In this study, it is trying to derive a

  13. Wave Energy, Lever Operated Pivoting Float LOPF Study

    DEFF Research Database (Denmark)

    Margheritini, Lucia

    The fully instrumented Resen Waves Lever Operated Pivoting Float LOPF wave energy buoy model has gone through the first stage of testing in regular waves in scale 1:25 of the North Sea wave conditions, in the 3D deep wave basin at the Hydraulic and Coastal Engineering Laboratory of Aalborg...... University in Denmark. The model size was 60cm W x 90cm L x 21cm H. The 60 cm width pointed towards the wave front. The LOPF buoy is characterized by a simple mechanical design with few moving parts and direct electrical output and it is taut moored to the sea bed, so all forces are referenced to the seabed...... for maximum energy output in regular as well as irregular waves. During storms the buoy pivots and streamlines itself to minimize loads on the mooring line. A conservative estimate shows that a full scale system for North Sea conditions has a float size width of 15 m that will, with 60% generator efficiency...

  14. Robotic arm

    Science.gov (United States)

    Kwech, Horst

    1989-04-18

    A robotic arm positionable within a nuclear vessel by access through a small diameter opening and having a mounting tube supported within the vessel and mounting a plurality of arm sections for movement lengthwise of the mounting tube as well as for movement out of a window provided in the wall of the mounting tube. An end effector, such as a grinding head or welding element, at an operating end of the robotic arm, can be located and operated within the nuclear vessel through movement derived from six different axes of motion provided by mounting and drive connections between arm sections of the robotic arm. The movements are achieved by operation of remotely-controllable servo motors, all of which are mounted at a control end of the robotic arm to be outside the nuclear vessel.

  15. Robotic arm

    International Nuclear Information System (INIS)

    Kwech, H.

    1989-01-01

    A robotic arm positionable within a nuclear vessel by access through a small diameter opening and having a mounting tube supported within the vessel and mounting a plurality of arm sections for movement lengthwise of the mounting tube as well as for movement out of a window provided in the wall of the mounting tube is disclosed. An end effector, such as a grinding head or welding element, at an operating end of the robotic arm, can be located and operated within the nuclear vessel through movement derived from six different axes of motion provided by mounting and drive connections between arm sections of the robotic arm. The movements are achieved by operation of remotely-controllable servo motors, all of which are mounted at a control end of the robotic arm to be outside the nuclear vessel. 23 figs

  16. The spiral arms of the Milky Way: The relative location of each different arm tracer within a typical spiral arm width

    Energy Technology Data Exchange (ETDEWEB)

    Vallée, Jacques P., E-mail: jacques.vallee@nrc-cnrc.gc.ca [National Research Council Canada, National Science Infrastructure portfolio, Herzberg Astronomy and Astrophysics, 5071 West Saanich Road, Victoria, B.C., V9E 2E7 (Canada)

    2014-07-01

    From the Sun's location in the Galactic disk, different arm tracers (CO, H I, hot dust, etc.) have been employed to locate a tangent to each spiral arm. Using all various and different observed spiral arm tracers (as published elsewhere), we embark on a new goal, namely the statistical analysis of these published data (data mining) to statistically compute the mean location of each spiral arm tracer. We show for a typical arm cross-cut, a separation of 400 pc between the mid-arm and the dust lane (at the inner edge of the arm, toward the Galactic center). Are some arms major and others minor? Separating arms into two sets, as suggested by some, we find the same arm widths between the two sets. Our interpretation is that we live in a multiple (four-arm) spiral (logarithmic) pattern (around a pitch angle of 12°) for the stars and gas in the Milky Way, with a sizable interarm separation (around 3 kpc) at the Sun's location and the same arm width for each arm (near 400 pc from mid-arm to dust lane).

  17. The spiral arms of the Milky Way: The relative location of each different arm tracer within a typical spiral arm width

    International Nuclear Information System (INIS)

    Vallée, Jacques P.

    2014-01-01

    From the Sun's location in the Galactic disk, different arm tracers (CO, H I, hot dust, etc.) have been employed to locate a tangent to each spiral arm. Using all various and different observed spiral arm tracers (as published elsewhere), we embark on a new goal, namely the statistical analysis of these published data (data mining) to statistically compute the mean location of each spiral arm tracer. We show for a typical arm cross-cut, a separation of 400 pc between the mid-arm and the dust lane (at the inner edge of the arm, toward the Galactic center). Are some arms major and others minor? Separating arms into two sets, as suggested by some, we find the same arm widths between the two sets. Our interpretation is that we live in a multiple (four-arm) spiral (logarithmic) pattern (around a pitch angle of 12°) for the stars and gas in the Milky Way, with a sizable interarm separation (around 3 kpc) at the Sun's location and the same arm width for each arm (near 400 pc from mid-arm to dust lane).

  18. Army-Navy Integration and the Pivot to the West: A New Joint Concept

    Science.gov (United States)

    2014-05-22

    rest on several principles focused on maintaining a “broad portfolio of military capabilities, offering versatility across the range of missions.”13...DC: Government Printing Office, 2010), 1; Mark E. Manyin et al., Pivot to the Pacific? The Obama Administration’s “ Rebalancing ” toward Asia...Lawrence, Michael F. Martin, Ronald O’Rourke, and Bruce Vaughn. Pivot to the Pacific? The Obama Administration’s “ Rebalancing ” toward Asia. Washington DC

  19. 78 FR 64415 - Special Conditions: Airbus, Model A350-900 Series Airplane; Ground Pivoting Loads

    Science.gov (United States)

    2013-10-29

    ...-abreast economy class layout, and accommodates side-by- side placement of LD-3 containers in the cargo... Committee, the Loads and Dynamics Harmonization Working Group developed criteria for determining pivoting... pivoting maneuver that takes into account the effects of the braking system and tire characteristics, in...

  20. Pivotal Teaching Moments in Technology-Intensive Secondary Geometry Classrooms

    Science.gov (United States)

    Cayton, Charity; Hollebrands, Karen; Okumus, Samet; Boehm, Ethan

    2017-01-01

    This study investigates three teachers' uses of a dynamic geometry program (The Geometer's Sketchpad) in their high school geometry classes over a 2-year period. The researchers examine teachers' actions and questions during pivotal teaching moments to characterize mathematics instruction that utilizes technology. Findings support an association…

  1. Evolution of robotic arms.

    Science.gov (United States)

    Moran, Michael E

    2007-01-01

    The foundation of surgical robotics is in the development of the robotic arm. This is a thorough review of the literature on the nature and development of this device with emphasis on surgical applications. We have reviewed the published literature and classified robotic arms by their application: show, industrial application, medical application, etc. There is a definite trend in the manufacture of robotic arms toward more dextrous devices, more degrees-of-freedom, and capabilities beyond the human arm. da Vinci designed the first sophisticated robotic arm in 1495 with four degrees-of-freedom and an analog on-board controller supplying power and programmability. von Kemplen's chess-playing automaton left arm was quite sophisticated. Unimate introduced the first industrial robotic arm in 1961, it has subsequently evolved into the PUMA arm. In 1963 the Rancho arm was designed; Minsky's Tentacle arm appeared in 1968, Scheinman's Stanford arm in 1969, and MIT's Silver arm in 1974. Aird became the first cyborg human with a robotic arm in 1993. In 2000 Miguel Nicolalis redefined possible man-machine capacity in his work on cerebral implantation in owl-monkeys directly interfacing with robotic arms both locally and at a distance. The robotic arm is the end-effector of robotic systems and currently is the hallmark feature of the da Vinci Surgical System making its entrance into surgical application. But, despite the potential advantages of this computer-controlled master-slave system, robotic arms have definite limitations. Ongoing work in robotics has many potential solutions to the drawbacks of current robotic surgical systems.

  2. Testing of the rectangular pivot-point bellows for the PPPL tokamak fusion test reactor

    International Nuclear Information System (INIS)

    Haughian, J.; Lou, K.; Greer, J.; Fong, M.; Scalise, D.T.

    1983-12-01

    The Neutral Beam Pivot Point Bellows (PPB) is installed in the duct which connects the Neutral Beam Enclosure to the Torus. This bellows, located at the pivot point, must fit the severely limited space available at the pivot-point location. Consequently, it has to be made rectangular in cross section with a large inside area for beam access. This leads to small convolutions with high stress concentrations. The function of the bellows is to permit change in the angular positioning of the neutral beam line with respect to the Tokamak, to isolate the Neutral Beam Line from the deflection of the Torus during bake out, and to allow for all misalignments. Internally the bellows will have a vacuum along with such gases such as hydrogen or deuterium. Tests parameters are described

  3. Clinical Outcome of Medial Pivot Compared With Press-Fit Condylar Sigma Cruciate-Retaining Mobile-Bearing Total Knee Arthroplasty.

    Science.gov (United States)

    Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik

    2017-10-01

    The purpose of this study was to compare the long-term clinical results, radiographic results, range of knee motion, patient satisfaction, and the survival rate of Medial-Pivot posterior cruciate-substituting, knee prosthesis and a press-fit condylar (PFC) Sigma cruciate-retaining mobile-bearing knee prosthesis in the same patients. One hundred eighty-two patients received Medial-Pivot knee prosthesis in one knee and a PFC Sigma knee prosthesis in the contralateral knee. The minimum duration of follow-up was 11 years (range, 11-12.6 years). The knees with a Medial-Pivot knee prosthesis had significantly worse results than those with a PFC Sigma knee prosthesis at the final follow-up with regard to the mean postoperative Knee Society knee scores (90 compared with 95 points), Western Ontario and McMaster Universities Osteoarthritis Index score (25 compared with 18 points), and range of knee motion (117° compared with 128°). Patients were more satisfied with PFC Sigma knee prosthesis (93%) than with Medial-Pivot knee prosthesis (75%). Complication rates were significantly higher in the Medial-Pivot knee group (26%) than those in the PFC Sigma knee group (6.5%). Radiographic results and survival rates (99% compared with 99.5%) were similar between the 2 groups. Although the long-term fixation and survival rate of both Medial-Pivot and PFC Sigma prostheses were similar, we observed a worse knee score, worse range of knee motion, and patient satisfaction was less in the Medial-Pivot knee group than in the PFC Sigma knee group. Furthermore, complication rate was also higher in the Medial-Pivot knee group than the other group. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Book Review Pivotal Love Relationships By Richard Alapack (2007 ...

    African Journals Online (AJOL)

    Love's Pivotal Relationships: The Chum, First Love, Outlaw and the Intimate Partner. Milton Keynes, UK/Bloomington, Indiana: AuthorHouse Press. Paperback (218 pages). ISBN: 978-1-434-31904-3. Hardcover (232 pages). ISBN: 978-1-434-32452-8. Indo-Pacific Journal of Phenomenology, Volume 8, Edition 1 May 2008 ...

  5. Isolated effects of peripheral arm and central body cooling on arm performance.

    Science.gov (United States)

    Giesbrecht, G G; Wu, M P; White, M D; Johnston, C E; Bristow, G K

    1995-10-01

    Whole body cooling impairs manual arm performance. The independent contributions of local (peripheral) and/or whole body (central) cooling are not known. Therefore, a protocol was developed in which the arm and the rest of the body could be independently cooled. Biceps temperature (Tmus), at a depth of 20 mm, and esophageal temperature (Tes) were measured. Six subjects were immersed to the clavicles in a tank (body tank) of water under 3 conditions: 1) cold body-cold arm (CB-CA); 2) warm body-cold arm (WB-CA); and 3) cold body-warm arm (CB-WA). In the latter two conditions, subjects placed their dominant arm in a separate (arm) tank. Water temperature (Tw) in each tank was independently controlled. In conditions requiring cold body and/or cold arm, Tw in the appropriate tanks was 8 degrees C. In conditions requiring warm body and/or warm arm, Tw in the appropriate tanks was adjusted between 29 and 38 degrees C to maintain body/arm temperature at baseline values. A battery of 6 tests, requiring fine or gross motor movements, were performed immediately before immersion and after 15, 45, and 70 minutes of immersion. In CB-CA, Tes decreased from an average of 37.2 to 35.6 degrees C and Tmus decreased from 34.6 to 22.0 degrees C. In WB-CA, Tmus decreased to 18.1 degrees C (Tes = 37.1 degrees C), and in CB-WA, Tes decreased to 35.8 degrees C (Tmus = 34.5 degrees C). By the end of immersion, there were significant decrements (43-85%) in the performance of all tests in CB-CA and WB-CA (p body and/or the arm elicits large decrements in finger, hand and arm performance. The decrements are due almost entirely to the local effects of arm tissue cooling.

  6. Unique characteristics of regulatory approval and pivotal studies of orphan anticancer drugs in Japan.

    Science.gov (United States)

    Nakayama, Hiroki; Tsukamoto, Katsura

    2018-04-17

    The approval of orphan anticancer drugs has increased, with the number exceeding that of non-orphan drugs in Japan in recent years. Although orphan anticancer drugs may have unique characteristics due to their rarity, these have not been fully characterized. We investigated anticancer drugs approved in Japan between April 2004 and November 2017 to reveal the characteristics of regulatory approval and pivotal studies on orphan anticancer drugs compared to non-orphan drugs. The median regulatory review time and number of patients in pivotal studies on orphan anticancer drugs (281.0 days [interquartile range, 263.3-336.0]; 222.5 patients [66.0-454.3]) were significantly lower than those on non-orphan drugs (353.0 days [277.0-535.5]; 521.0 patients [303.5-814.5], respectively) (P < 0.001). Phase II, non-randomized and non-controlled designs were more frequently used in pivotal studies on orphan anticancer drugs (45.9%, 41.9% and 43.2%) than non-orphan drugs (17.2%, 14.1% and 14.1%, respectively). Response rate was more commonly used as a primary endpoint in pivotal studies on orphan anticancer drugs (48.6%) than non-orphan drugs (17.2%). Indications limited by molecular features, second or later treatment line, and accelerated approval in the United States were associated with the use of response rate in orphan anticancer drug studies. In conclusion, we demonstrated that orphan anticancer drugs in Japan have unique characteristics compared to non-orphan drugs: shorter regulatory review and pivotal studies frequently using phase II, non-randomized, or non-controlled designs and response rate as a primary endpoint, with fewer patients.

  7. European Marketing Authorizations Granted Based on a Single Pivotal Clinical Trial: The Rule or the Exception?

    Science.gov (United States)

    Morant, Anne Vinther; Vestergaard, Henrik Tang

    2018-07-01

    A minimum of two positive, adequate, and well-controlled clinical trials has historically been the gold standard for providing substantial evidence to support regulatory approval of a new medicine. Nevertheless, the present analysis of European Marketing Authorizations granted between 2012 and 2016 showed that 45% of new active substances were approved based on a single pivotal clinical trial. For therapeutic areas such as oncology and cardiovascular diseases, approvals based on a single pivotal trial are the rule rather than the exception, whereas new medicines within the nervous system area were generally supported by two or more pivotal trials. While overall similar trends have been observed in the US, the recent US Food and Drug Administration approvals of nervous system medicines based on a single pivotal trial suggest that a case-by-case scientific evaluation of the totality of evidence is increasingly applied to facilitate faster access of new medicines to patients suffering from serious diseases. © 2017 American Society for Clinical Pharmacology and Therapeutics.

  8. Russian “Pivot to the East” Strategy: Opportunities and Challenges for Coupling with Chinese Transregional Projectsy

    Directory of Open Access Journals (Sweden)

    Ma Bo

    2017-01-01

    Full Text Available Ukrainian Crisis of 2014 is crucial for Russian pivot to the East which is considered to be a tool for tackling economic challenges and avoiding diplomatic isolation. Economically, this pivot implies cooperation with AsiaPacific region in trade and energy. Politically, it means closer ties with the states of that region. At the same time, the success of the strategy hinges on the state of affairs in energy and on promoting to Asian markets specifi c goods that turns out to be a constraint for diversifi cation of the Russian economy. Moreover, culturally and social Russia is much closer to Europe than Asia, and that is one more obstacle to “Pivot to the East” strategy realization. However, transregional projects of the recent years, including Chinese initiative “One Belt – One Road” and Russian “Pivot to the East” might be key to enhance the strategic potential of Russia-China cooperation which meets Chinese national interests.

  9. Have Third-World Arms Industries Reduced Arms Imports?

    OpenAIRE

    Looney, R.E.

    1989-01-01

    Current Research on Peace and Violence, no. 1, 1989. Refereed Journal Article In 1945 only Argentina, Brazil, India and South Africa in the Third World possessed domestic arms industries which produced weapons systems other than small arms and ammunition (SIPRI, 1987, 76).

  10. Application of ceramics to the sliding seat of valve bridge; Valve bridge yodobu eno ceramics tekiyo

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, T; Ono, T [Mitsubishi Motors Corp., Tokyo (Japan)

    1997-10-01

    For use in the valve train, using an OHV (over head valve) configuration. of a 4 valve diesel engine for trucks and buses; we developed a valve bridge, a component of a valve train, with a ceramic head that is made of silicon nitride(Si3N4) in contact with a rocker arm in order to reduce cost and improve wear resistance for further diesel engine emissions regulations. In order to evaluate the effect of this valve bridge, RIG tests and durability tests on actual engines were carried out. 7 figs., 2 tabs.

  11. Arm Pain

    Science.gov (United States)

    ... be a sign of a heart attack. Seek emergency treatment if you have: Arm, shoulder or back ... http://www.mayoclinic.org/symptoms/arm-pain/basics/definition/SYM-20050870 . Mayo Clinic Footer Legal Conditions and ...

  12. N-Dimensional LLL Reduction Algorithm with Pivoted Reflection

    Directory of Open Access Journals (Sweden)

    Zhongliang Deng

    2018-01-01

    Full Text Available The Lenstra-Lenstra-Lovász (LLL lattice reduction algorithm and many of its variants have been widely used by cryptography, multiple-input-multiple-output (MIMO communication systems and carrier phase positioning in global navigation satellite system (GNSS to solve the integer least squares (ILS problem. In this paper, we propose an n-dimensional LLL reduction algorithm (n-LLL, expanding the Lovász condition in LLL algorithm to n-dimensional space in order to obtain a further reduced basis. We also introduce pivoted Householder reflection into the algorithm to optimize the reduction time. For an m-order positive definite matrix, analysis shows that the n-LLL reduction algorithm will converge within finite steps and always produce better results than the original LLL reduction algorithm with n > 2. The simulations clearly prove that n-LLL is better than the original LLL in reducing the condition number of an ill-conditioned input matrix with 39% improvement on average for typical cases, which can significantly reduce the searching space for solving ILS problem. The simulation results also show that the pivoted reflection has significantly declined the number of swaps in the algorithm by 57%, making n-LLL a more practical reduction algorithm.

  13. Efficient Storage and Querying of Horizontal Tables Using a PIVOT Operation in Commercial Relational DBMSs

    Science.gov (United States)

    Shin, Sung-Hyun; Moon, Yang-Sae; Kim, Jinho; Kim, Sang-Wook

    In recent years, a horizontal table with a large number of attributes is widely used in OLAP or e-business applications to analyze multidimensional data efficiently. For efficient storing and querying of horizontal tables, recent works have tried to transform a horizontal table to a traditional vertical table. Existing works, however, have the drawback of not considering an optimized PIVOT operation provided (or to be provided) in recent commercial RDBMSs. In this paper we propose a formal approach that exploits the optimized PIVOT operation of commercial RDBMSs for storing and querying of horizontal tables. To achieve this goal, we first provide an overall framework that stores and queries a horizontal table using an equivalent vertical table. Under the proposed framework, we then formally define 1) a method that stores a horizontal table in an equivalent vertical table and 2) a PIVOT operation that converts a stored vertical table to an equivalent horizontal view. Next, we propose a novel method that transforms a user-specified query on horizontal tables to an equivalent PIVOT-included query on vertical tables. In particular, by providing transformation rules for all five elementary operations in relational algebra as theorems, we prove our method is theoretically applicable to commercial RDBMSs. Experimental results show that, compared with the earlier work, our method reduces storage space significantly and also improves average performance by several orders of magnitude. These results indicate that our method provides an excellent framework to maximize performance in handling horizontal tables by exploiting the optimized PIVOT operation in commercial RDBMSs.

  14. Two independent pivotal statistics that test location and misspecification and add-up to the Anderson-Rubin statistic

    NARCIS (Netherlands)

    Kleibergen, F.R.

    2002-01-01

    We extend the novel pivotal statistics for testing the parameters in the instrumental variables regression model. We show that these statistics result from a decomposition of the Anderson-Rubin statistic into two independent pivotal statistics. The first statistic is a score statistic that tests

  15. Examination of Studies Targeting Social Skills with Pivotal Response Treatment

    Science.gov (United States)

    Bozkus Genc, Gulden; Vuran, Sezgin

    2013-01-01

    In early education, especially in effective teaching to children with autism spectrum disorders, the teaching methods which are applicable in natural settings like pivotal response treatment (PRT) are commonly used. It is one of the naturalistic intervention models aiming to facilitate the stimulant-response generalization, decrease the dependency…

  16. Performance evaluation of a center pivot variable rate irrigation system

    Science.gov (United States)

    Variable Rate Irrigation (VRI) for center pivots offers potential to match specific application rates to non-uniform soil conditions along the length of the lateral. The benefit of such systems is influenced by the areal extent of these variations and the smallest scale to which the irrigation syste...

  17. Electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength after stroke.

    Science.gov (United States)

    Mehrholz, Jan; Pohl, Marcus; Platz, Thomas; Kugler, Joachim; Elsner, Bernhard

    2015-11-07

    Electromechanical and robot-assisted arm training devices are used in rehabilitation, and may help to improve arm function after stroke. To assess the effectiveness of electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength in people after stroke. We also assessed the acceptability and safety of the therapy. We searched the Cochrane Stroke Group's Trials Register (last searched February 2015), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library 2015, Issue 3), MEDLINE (1950 to March 2015), EMBASE (1980 to March 2015), CINAHL (1982 to March 2015), AMED (1985 to March 2015), SPORTDiscus (1949 to March 2015), PEDro (searched April 2015), Compendex (1972 to March 2015), and Inspec (1969 to March 2015). We also handsearched relevant conference proceedings, searched trials and research registers, checked reference lists, and contacted trialists, experts, and researchers in our field, as well as manufacturers of commercial devices. Randomised controlled trials comparing electromechanical and robot-assisted arm training for recovery of arm function with other rehabilitation or placebo interventions, or no treatment, for people after stroke. Two review authors independently selected trials for inclusion, assessed trial quality and risk of bias, and extracted data. We contacted trialists for additional information. We analysed the results as standardised mean differences (SMDs) for continuous variables and risk differences (RDs) for dichotomous variables. We included 34 trials (involving 1160 participants) in this update of our review. Electromechanical and robot-assisted arm training improved activities of daily living scores (SMD 0.37, 95% confidence interval (CI) 0.11 to 0.64, P = 0.005, I² = 62%), arm function (SMD 0.35, 95% CI 0.18 to 0.51, P arm muscle strength (SMD 0.36, 95% CI 0.01 to 0.70, P = 0.04, I² = 72%), but the quality of the evidence was low to very low

  18. Coordinating Upper and Lower Body During FES-Assisted Transfers in Persons With Spinal Cord Injury in Order to Reduce Arm Support.

    Science.gov (United States)

    Jovic, Jovana; Azevedo Coste, Christine; Fraisse, Philippe; Henkous, Sonia; Fattal, Charles

    2015-12-01

    The goal of this study is to minimize arm forces applied during sit-to-stand (STS) transfers in persons with spinal cord injury (SCI) by using functional electrical stimulation (FES) applied to lower limbs muscles. A new FES system has been used to automatically trigger muscle stimulation of the lower limbs, at the desired moment in regards to trunk motion. The objective was to decrease arm participation during STS motion of a person with complete paraplegia and low-level tetraplegia. Six participants with chronic SCI participated in the study. Participants with SCI were recruited to complete STS movement using a new system for FES-assisted STS transfer. All participants attended one muscle mapping session to test their muscles condition, two training sessions to become familiarized with the experimental setup, and two measurement sessions using the proposed system for FES-assisted STS movement. The applied arm forces during STS movement were recorded and analyzed for different stimulation onset values with respect to the maximal trunk acceleration signal using one-way ANOVA statistical test. Post-hoc analysis was performed using Tukey's method. The results of this study showed that the moment of the stimulation onset has an influence on the arm forces applied during the STS motion. The lowest values of arm forces were obtained for STS movements where the electrical stimulation was triggered before and around the time corresponding to the maximal value of the trunk acceleration signal. Lowest arm forces values were obtained for STS motions that were similar to those of healthy persons in terms of trunk movements and beginning of lower limb movements in regards to maximal trunk acceleration signal. The FES system was able to mimic the rising motion of a healthy individual by triggering the FES at the appropriate moment. This method could prove useful for pivot transfer, therapeutic or functional verticalization. © 2015 International Neuromodulation Society.

  19. Re-use of pilot data and interim analysis of pivotal data in MRMC studies: a simulation study

    Science.gov (United States)

    Chen, Weijie; Samuelson, Frank; Sahiner, Berkman; Petrick, Nicholas

    2017-03-01

    Novel medical imaging devices are often evaluated with multi-reader multi-case (MRMC) studies in which radiologists read images of patient cases for a specified clinical task (e.g., cancer detection). A pilot study is often used to measure the effect size and variance parameters that are necessary for sizing a pivotal study (including sizing readers, non-diseased and diseased cases). Due to the practical difficulty of collecting patient cases or recruiting clinical readers, some investigators attempt to include the pilot data as part of their pivotal study. In other situations, some investigators attempt to perform an interim analysis of their pivotal study data based upon which the sample sizes may be re-estimated. Re-use of the pilot data or interim analyses of the pivotal data may inflate the type I error of the pivotal study. In this work, we use the Roe and Metz model to simulate MRMC data under the null hypothesis (i.e., two devices have equal diagnostic performance) and investigate the type I error rate for several practical designs involving re-use of pilot data or interim analysis of pivotal data. Our preliminary simulation results indicate that, under the simulation conditions we investigated, the inflation of type I error is none or only marginal for some design strategies (e.g., re-use of patient data without re-using readers, and size re-estimation without using the effect-size estimated in the interim analysis). Upon further verifications, these are potentially useful design methods in that they may help make a study less burdensome and have a better chance to succeed without substantial loss of the statistical rigor.

  20. ARM Airborne Carbon Measurements (ARM-ACME) and ARM-ACME 2.5 Final Campaign Reports

    Energy Technology Data Exchange (ETDEWEB)

    Biraud, S. C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Tom, M. S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sweeney, C. [NOAA Earth Systems Research Lab., Boulder, CO (United States)

    2016-01-01

    We report on a 5-year multi-institution and multi-agency airborne study of atmospheric composition and carbon cycling at the Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Southern Great Plains (SGP) site, with scientific objectives that are central to the carbon-cycle and radiative-forcing goals of the U.S. Global Change Research Program and the North American Carbon Program (NACP). The goal of these measurements is to improve understanding of 1) the carbon exchange of the Atmospheric Radiation Measurement (ARM) SGP region; 2) how CO2 and associated water and energy fluxes influence radiative-forcing, convective processes, and CO2 concentrations over the ARM SGP region, and 3) how greenhouse gases are transported on continental scales.

  1. Powered manipulator control arm

    International Nuclear Information System (INIS)

    Le Mouee, Theodore; Vertut, Jean; Marchal, Paul; Germon, J.C.; Petit, Michel

    1975-01-01

    A remote operated control arm for powered manipulators is described. It includes an assembly allowing several movements with position sensors for each movement. The number of possible arm movements equals the number of possible manipulator movements. The control systems may be interrupted as required. One part of the arm is fitted with a system to lock it with respect to another part of the arm without affecting the other movements, so long as the positions of the manipulator and the arm have not been brought into complete coincidence. With this system the locking can be ended when complete concordance is achieved [fr

  2. ARM Airborne Carbon Measurements VI (ARM-ACME VI) Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Biraud, Sebastien [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-05-01

    From October 1, 2015 through September 30, 2016, AAF deployed a Cessna 206 aircraft over the Southern Great Plains, collecting observations of trace gas mixing ratios over the ARM/SGP Central Facility. The aircraft payload included two Atmospheric Observing Systems (AOS Inc.) analyzers for continuous measurements of CO2, and a 12-flask sampler for analysis of carbon cycle gases (CO2, CO, CH4, N2O, 13CO2). The aircraft payload also includes solar/infrared radiation measurements. This research (supported by DOE ARM and TES programs) builds upon previous ARM-ACME missions. The goal of these measurements is to improve understanding of: (a) the carbon exchange of the ARM region; (b) how CO2 and associated water and energy fluxes influence radiative forcing, convective processes, and CO2 concentrations over the ARM region, and (c) how greenhouse gases are transported on continental scales.

  3. ARM Mentor Selection Process

    Energy Technology Data Exchange (ETDEWEB)

    Sisterson, D. L. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-10-01

    The Atmospheric Radiation Measurement (ARM) Program was created in 1989 with funding from the U.S. Department of Energy (DOE) to develop several highly instrumented ground stations to study cloud formation processes and their influence on radiative transfer. In 2003, the ARM Program became a national scientific user facility, known as the ARM Climate Research Facility. This scientific infrastructure provides for fixed sites, mobile facilities, an aerial facility, and a data archive available for use by scientists worldwide through the ARM Climate Research Facility—a scientific user facility. The ARM Climate Research Facility currently operates more than 300 instrument systems that provide ground-based observations of the atmospheric column. To keep ARM at the forefront of climate observations, the ARM infrastructure depends heavily on instrument scientists and engineers, also known as lead mentors. Lead mentors must have an excellent understanding of in situ and remote-sensing instrumentation theory and operation and have comprehensive knowledge of critical scale-dependent atmospheric processes. They must also possess the technical and analytical skills to develop new data retrievals that provide innovative approaches for creating research-quality data sets. The ARM Climate Research Facility is seeking the best overall qualified candidate who can fulfill lead mentor requirements in a timely manner.

  4. "Palmar pivot flap" for resurfacing palmar lateral defects of the fingers.

    Science.gov (United States)

    Yam, Andrew; Peng, Yeong-Pin; Pho, Robert Wan-Heng

    2008-12-01

    Soft tissue defects on the lateral borders of the digits are difficult to reconstruct using local or local-regional flaps. We describe a "palmar pivot flap" to resurface an adjacent defect on the palmar-lateral aspect of the digit. The surgical technique is described. This flap is an axial pattern flap based on the subcutaneous transverse branches of the digital artery. The flap is pivoted up to 90 degrees on the neurovascular bundle in its base, into an adjacent defect. The flap can be raised from either the proximal or the middle phalangeal segments. It can cover defects sited from the level of the proximal interphalangeal joint up to the fingertip. The donor defect is limited to the same digit and is covered with a full-thickness skin graft. We have used this flap on 3 patients with defects at the middle phalangeal segment, the distal interphalangeal joint, and the fingertip. All healed primarily. One patient had a mild flexion contracture of the proximal interphalangeal joint, whereas the other 2 had no complications. The patients with distal interphalangeal joint and fingertip defects had excellent sensation in the flap (2-point discrimination of 5-6 mm). The palmar pivot flap is useful for resurfacing otherwise difficult defects on the lateral borders of the digits around and distal to the proximal interphalangeal joint, including those at the fingertip. It provides sensate, glabrous skin. The donor defect is on the same digit and is well hidden, producing an aesthetic and functional reconstruction.

  5. The arms race control

    International Nuclear Information System (INIS)

    Nemo, J.

    2010-01-01

    Written in 1961, this paper presents the content of a book entitled 'The arms race control' where the author outlined the difference between disarmament and arms control, described the economic and moral role of arms race, the importance of force balance for international security. He wandered whether arms control could ensure this balance and whether nuclear balance meant force balance. Force balance then appears to be a precarious and unsteady component of international security. He commented the challenges of disarmament, recalled some arguments for a nuclear disarmament. Then he discussed what would be an arms control with or without disarmament (either nuclear or conventional)

  6. How do octopuses use their arms?

    Science.gov (United States)

    Mather, J A

    1998-09-01

    A taxonomy of the movement patterns of the 8 flexible arms of octopuses is constructed. Components consist of movements of the arm itself, the ventral suckers and their stalks, as well as the relative position of arms and the skin web between them. Within 1 arm, combinations of components result in a variety of behaviors. At the level of all arms, 1 group of behaviors is described as postures, on the basis of the spread of all arms and the web to make a 2-dimensional surface whose position differs in the 3rd dimension. Another group of arm behaviors is actions, more or less coordinated and involving several to all arms. Arm control appears to be based on radial symmetry, relative equipotentiality of all arms, relative independence of each arm, and separability of components within the arm. The types and coordination of arm behaviors are discussed with relationship to biomechanical limits, muscle structures, and neuronal programming.

  7. Robotic-Movement Payload Lifter and Manipulator

    Science.gov (United States)

    Doggett, William R. (Inventor); King, Bruce D. (Inventor); Collins, Timothy J. (Inventor); Dorsey, John T. (Inventor)

    2011-01-01

    A payload lifter/manipulator module includes a rotatable joint supporting spreader arms angularly spaced with respect to one another. A rigid arm is fixedly coupled to the joint and extends out therefrom to a tip. A tension arm has a first end and a second end with the first end being fixedly coupled to the tip of the rigid arm. The tension arm incorporates pivots along the length thereof. Each pivot can be engaged by or disengaged from the outboard end of a spreader arm based on a position of the spreader arm. A hoist, positioned remotely with respect to the module and coupled to the second end of the tension arm, controls the position of the spreader arms to thereby control the position of the rigid arm's tip. Payload lifter/manipulator assemblies can be constructed with one or more of the modules.

  8. Device with pivoting base for the storage of nuclear fuel

    International Nuclear Information System (INIS)

    Raymond, T.E.

    1978-01-01

    A storage rack for nuclear fuel assemblies comprising lower and upper bearers to support and hold fuel assemblies in their vertical position is described. The feature of this rack is the lower supporting device which comprises a pivoting base on which rests each fuel assembly, thereby enabling the fuel assembly not be subjected to any fatigue during storage [fr

  9. CyARM: Haptic Sensing Device for Spatial Localization on Basis of Exploration by Arms

    Directory of Open Access Journals (Sweden)

    Junichi Akita

    2009-01-01

    Full Text Available We introduce a new type of perception aid device based on user's exploration action, which is named as CyARM (acronym of “Cyber Arm”. The user holds this device in her/his arm, the extension of the arm is controlled by tension in wires, which are attached to her/his body according to the distance to the object. This user interface has unique characteristics that give users the illusion of an imaginary arm that extends to existing objects. The implementations of CyARM and our two experiments to investigate the efficiency and effectiveness of CyARM are described. The results show that we could confirm that CyARM can be used to recognize the presence of an object in front of the user and to measure the relative distance to the object.

  10. The testing of the Rectangular Pivot-point bellows for the PPPL Tokamak fusion test reactor

    International Nuclear Information System (INIS)

    Haughian, J.; Fong, M.; Greer, J.; Lou, K.; Scalise, D.T.

    1983-01-01

    The Neutral Beam Pivot Point Bellows (PPB) is installed in the duct which connects the Neutral Beam Enclosure to the Torus. This bellows, located at the pivot point, must fit the severely limited space available at the pivot-point location. Consequently, it has to be made rectangular in cross section with a large inside area for beam access. This leads to small convolutions with high stress concentrations. The function of the bellows is to permit change in the angular positioning of the neutral beam line with respect to the Tokamak, to isolate the Neutral Beam Line from the deflection of the Torus during bake out, and to allow for all misalignments. Internally the bellows will have a vacuum along with such gases such as hydrogen or deuterium. Externally, air or nitrogen gas will be present. It is constructed of Inconel 718 convolutions welded together to provide a clear rectangular opening of 23.4 by 32.2 inches, joined to a 625 Inconel flange at each end

  11. Golden prospects for uranium mine

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    Beisa Mines Ltd, a wholly-owned subsidiary of Union Corporation, looks a born winner. Although only due for completion in 1982 it can already boast several 'firsts' in the mining industry. It is, of course, the first mine in South Africa to be developed as a primary producer of uranium with gold as a by-product. Its No. 1 Ventilation Shaft is also the smallest diameter shaft in SA to use a rocker-arm shovel loader for rock removal. Moreover, Beisa will be the first mine to use the revolutionary carbon-in-pulp process on a large scale

  12. Armed conflict and child health.

    Science.gov (United States)

    Rieder, Michael; Choonara, Imti

    2012-01-01

    Armed conflict has a major impact on child health throughout the world. One in six children worldwide lives in an area of armed conflict and civilians are more likely to die than soldiers as a result of the conflict. In stark contrast to the effect on children, the international arms trade results in huge profits for the large corporations involved in producing arms, weapons and munitions. Armed conflict is not inevitable but is an important health issue that should be prevented.

  13. Hello to Arms

    Science.gov (United States)

    2005-01-01

    This image highlights the hidden spiral arms (blue) that were discovered around the nearby galaxy NGC 4625 by the ultraviolet eyes of NASA's Galaxy Evolution Explorer. The image is composed of ultraviolet and visible-light data, from the Galaxy Evolution Explorer and the California Institute of Technology's Digitized Sky Survey, respectively. Near-ultraviolet light is colored green; far-ultraviolet light is colored blue; and optical light is colored red. As the image demonstrates, the lengthy spiral arms are nearly invisible when viewed in optical light while bright in ultraviolet. This is because they are bustling with hot, newborn stars that radiate primarily ultraviolet light. The youthful arms are also very long, stretching out to a distance four times the size of the galaxy's core. They are part of the largest ultraviolet galactic disk discovered so far. Located 31 million light-years away in the constellation Canes Venatici, NGC 4625 is the closest galaxy ever seen with such a young halo of arms. It is slightly smaller than our Milky Way, both in size and mass. However, the fact that this galaxy's disk is forming stars very actively suggests that it might evolve into a more massive and mature galaxy resembling our own. The armless companion galaxy seen below NGC 4625 is called NGC 4618. Astronomers do not know why it lacks arms but speculate that it may have triggered the development of arms in NGC 4625.

  14. Visual Display of 5p-arm and 3p-arm miRNA Expression with a Mobile Application.

    Science.gov (United States)

    Pan, Chao-Yu; Kuo, Wei-Ting; Chiu, Chien-Yuan; Lin, Wen-Chang

    2017-01-01

    MicroRNAs (miRNAs) play important roles in human cancers. In previous studies, we have demonstrated that both 5p-arm and 3p-arm of mature miRNAs could be expressed from the same precursor and we further interrogated the 5p-arm and 3p-arm miRNA expression with a comprehensive arm feature annotation list. To assist biologists to visualize the differential 5p-arm and 3p-arm miRNA expression patterns, we utilized a user-friendly mobile App to display. The Cancer Genome Atlas (TCGA) miRNA-Seq expression information. We have collected over 4,500 miRNA-Seq datasets from 15 TCGA cancer types and further processed them with the 5p-arm and 3p-arm annotation analysis pipeline. In order to be displayed with the RNA-Seq Viewer App, annotated 5p-arm and 3p-arm miRNA expression information and miRNA gene loci information were converted into SQLite tables. In this distinct application, for any given miRNA gene, 5p-arm miRNA is illustrated on the top of chromosome ideogram and 3p-arm miRNA is illustrated on the bottom of chromosome ideogram. Users can then easily interrogate the differentially 5p-arm/3p-arm expressed miRNAs with their mobile devices. This study demonstrates the feasibility and utility of RNA-Seq Viewer App in addition to mRNA-Seq data visualization.

  15. Visual Display of 5p-arm and 3p-arm miRNA Expression with a Mobile Application

    Directory of Open Access Journals (Sweden)

    Chao-Yu Pan

    2017-01-01

    Full Text Available MicroRNAs (miRNAs play important roles in human cancers. In previous studies, we have demonstrated that both 5p-arm and 3p-arm of mature miRNAs could be expressed from the same precursor and we further interrogated the 5p-arm and 3p-arm miRNA expression with a comprehensive arm feature annotation list. To assist biologists to visualize the differential 5p-arm and 3p-arm miRNA expression patterns, we utilized a user-friendly mobile App to display. The Cancer Genome Atlas (TCGA miRNA-Seq expression information. We have collected over 4,500 miRNA-Seq datasets from 15 TCGA cancer types and further processed them with the 5p-arm and 3p-arm annotation analysis pipeline. In order to be displayed with the RNA-Seq Viewer App, annotated 5p-arm and 3p-arm miRNA expression information and miRNA gene loci information were converted into SQLite tables. In this distinct application, for any given miRNA gene, 5p-arm miRNA is illustrated on the top of chromosome ideogram and 3p-arm miRNA is illustrated on the bottom of chromosome ideogram. Users can then easily interrogate the differentially 5p-arm/3p-arm expressed miRNAs with their mobile devices. This study demonstrates the feasibility and utility of RNA-Seq Viewer App in addition to mRNA-Seq data visualization.

  16. Sensory-Feedback Exoskeletal Arm Controller

    Science.gov (United States)

    An, Bin; Massie, Thomas H.; Vayner, Vladimir

    2004-01-01

    An electromechanical exoskeletal arm apparatus has been designed for use in controlling a remote robotic manipulator arm. The apparatus, called a force-feedback exoskeleton arm master (F-EAM) is comfortable to wear and easy to don and doff. It provides control signals from the wearer s arm to a robot arm or a computer simulator (e.g., a virtual-reality system); it also provides force and torque feedback from sensors on the robot arm or from the computer simulator to the wearer s arm. The F-EAM enables the wearer to make the robot arm gently touch objects and finely manipulate them without exerting excessive forces. The F-EAM features a lightweight design in which the motors and gear heads that generate force and torque feedback are made smaller than they ordinarily would be: this is achieved by driving the motors to power levels greater than would ordinarily be used in order to obtain higher torques, and by providing active liquid cooling of the motors to prevent overheating at the high drive levels. The F-EAM (see figure) includes an assembly that resembles a backpack and is worn like a backpack, plus an exoskeletal arm mechanism. The FEAM has five degrees of freedom (DOFs) that correspond to those of the human arm: 1. The first DOF is that of the side-to-side rotation of the upper arm about the shoulder (rotation about axis 1). The reflected torque for this DOF is provided by motor 1 via drum 1 and a planar four-bar linkage. 2. The second DOF is that of the up-and-down rotation of the arm about the shoulder. The reflected torque for this DOF is provided by motor 2 via drum 2. 3. The third DOF is that of twisting of the upper arm about its longitudinal axis. This DOF is implemented in a cable remote-center mechanism (CRCM). The reflected torque for this DOF is provided by motor 3, which drives the upper-arm cuff and the mechanism below it. A bladder inflatable by gas or liquid is placed between the cuff and the wearer s upper arm to compensate for misalignment

  17. Instance Analysis for the Error of Three-pivot Pressure Transducer Static Balancing Method for Hydraulic Turbine Runner

    Science.gov (United States)

    Weng, Hanli; Li, Youping

    2017-04-01

    The working principle, process device and test procedure of runner static balancing test method by weighting with three-pivot pressure transducers are introduced in this paper. Based on an actual instance of a V hydraulic turbine runner, the error and sensitivity of the three-pivot pressure transducer static balancing method are analysed. Suggestions about improving the accuracy and the application of the method are also proposed.

  18. Unequal-Arms Michelson Interferometers

    Science.gov (United States)

    Tinto, Massimo; Armstrong, J. W.

    2000-01-01

    Michelson interferometers allow phase measurements many orders of magnitude below the phase stability of the laser light injected into their two almost equal-length arms. If, however, the two arms are unequal, the laser fluctuations can not be removed by simply recombining the two beams. This is because the laser jitters experience different time delays in the two arms, and therefore can not cancel at the photo detector. We present here a method for achieving exact laser noise cancellation, even in an unequal-arm interferometer. The method presented in this paper requires a separate readout of the relative phase in each arm, made by interfering the returning beam in each arm with a fraction of the outgoing beam. By linearly combining the two data sets with themselves, after they have been properly time shifted, we show that it is possible to construct a new data set that is free of laser fluctuations. An application of this technique to future planned space-based laser interferometer detector3 of gravitational radiation is discussed.

  19. Pivoting output unit control systems activated by jacks. [for controlling aircraft flaps

    Science.gov (United States)

    Belliere, P.

    1978-01-01

    An invention to be used for controlling aircraft flaps is described. It is applicable to control systems with two coaxial output units which pivot simultaneously with respect to two fixed units and which are activated by two opposed, straight coaxial jacks.

  20. Compactable control element assembly for a nuclear reactor

    International Nuclear Information System (INIS)

    Dupen, C.F.G.

    1976-01-01

    A description is given of a compactable control element assembly for a nuclear reactor in which the absorber pins of the assembly are compacted during downward movement of the pin and are returned to their uncompacted state when downward movement is stopped. The control element assembly comprises a support member longitudinally movable within a control assembly duct and a plurality of absorber pins supported laterally outward of the support member and within the duct by pairs of support arms. The absorber pins are pivotably mounted to the support arms and the support arms in turn are supported from the support member for upward pivotable movement in a longitudinal plane. As the support member is moved downward, the support arms pivot upwardly and the absorber pins move upwardly and inwardly towards the support member. When the support member is stopped the absorber pins return to their uncompacted position

  1. Armed conflict and child health

    OpenAIRE

    Rieder, Michael; Choonara, Imti

    2012-01-01

    Armed conflict has a major impact on child health\\ud throughout the world. One in six children worldwide lives\\ud in an area of armed conflict and civilians are more likely\\ud to die than soldiers as a result of the conflict. In stark\\ud contrast to the effect on children, the international arms\\ud trade results in huge profits for the large corporations\\ud involved in producing arms, weapons and munitions.\\ud Armed conflict is not inevitable but is an important\\ud health issue that should be...

  2. Dynamic behavior of air lubricated pivoted-pad journal-bearing, rotor system. 2: Pivot consideration and pad mass

    Science.gov (United States)

    Nemeth, Z. N.

    1972-01-01

    Rotor bearing dynamic tests were conducted with tilting-pad journal bearings having three different pad masses and two different pivot geometries. The rotor was vertically mounted and supported by two three-pad tilting-pad gas journal bearings and a simple externally pressurized thrust bearing. The bearing pads were 5.1 cm (2.02 in.) in diameter and 2.8 cm (1.5 in.) long. The length to diameter ratio was 0.75. One pad was mounted on a flexible diaphragm. The bearing supply pressure ranged from 0 to 690 kilonewtons per square meter (0 to 100 psig), and speeds ranged to 38,500 rpm. Heavy mass pad tilting-pad assemblies produced three rotor-bearing resonances above the first two rotor critical speeds. Lower supply pressure eliminated the resonances. The resonances were oriented primarily in the direction normal to the diaphragm.

  3. Effects of age, sex and arm on the precision of arm position sense—left-arm superiority in healthy right-handers

    OpenAIRE

    Schmidt, Lena; Depper, Lena; Kerkhoff, Georg

    2013-01-01

    Position sense is an important proprioceptive ability. Disorders of arm position sense (APS) often occur after unilateral stroke, and are associated with a negative functional outcome. In the present study we assessed horizontal APS by measuring angular deviations from a visually defined target separately for each arm in a large group of healthy subjects. We analyzed the accuracy and instability of horizontal APS as a function of age, sex and arm. Subjects were required to specify verbally th...

  4. Performance of arm locking in LISA

    International Nuclear Information System (INIS)

    McKenzie, Kirk; Spero, Robert E.; Shaddock, Daniel A.

    2009-01-01

    For the Laser Interferometer Space Antenna (LISA) to reach its design sensitivity, the coupling of the free-running laser frequency noise to the signal readout must be reduced by more than 14 orders of magnitude. One technique employed to reduce the laser frequency noise will be arm locking, where the laser frequency is locked to the LISA arm length. In this paper we detail an implementation of arm locking. We investigate orbital effects (changing arm lengths and Doppler frequencies), the impact of errors in the Doppler knowledge that can cause pulling of the laser frequency, and the noise limit of arm locking. Laser frequency pulling is examined in two regimes: at lock acquisition and in steady state. The noise performance of arm locking is calculated with the inclusion of the dominant expected noise sources: ultrastable oscillator (clock) noise, spacecraft motion, and shot noise. We find that clock noise and spacecraft motion limit the performance of dual arm locking in the LISA science band. Studying these issues reveals that although dual arm locking [A. Sutton and D. A. Shaddock, Phys. Rev. D 78, 082001 (2008)] has advantages over single (or common) arm locking in terms of allowing high gain, it has disadvantages in both laser frequency pulling and noise performance. We address this by proposing a modification to the dual arm-locking sensor, a hybrid of common and dual arm-locking sensors. This modified dual arm-locking sensor has the laser frequency pulling characteristics and low-frequency noise coupling of common arm locking, but retains the control system advantages of dual arm locking. We present a detailed design of an arm-locking controller and perform an analysis of the expected performance when used with and without laser prestabilization. We observe that the sensor phase changes beneficially near unity-gain frequencies of the arm-locking controller, allowing a factor of 10 more gain than previously believed, without degrading stability. With a time

  5. Design of a multi-arm randomized clinical trial with no control arm.

    Science.gov (United States)

    Magaret, Amalia; Angus, Derek C; Adhikari, Neill K J; Banura, Patrick; Kissoon, Niranjan; Lawler, James V; Jacob, Shevin T

    2016-01-01

    Clinical trial designs that include multiple treatments are currently limited to those that perform pairwise comparisons of each investigational treatment to a single control. However, there are settings, such as the recent Ebola outbreak, in which no treatment has been demonstrated to be effective; and therefore, no standard of care exists which would serve as an appropriate control. For illustrative purposes, we focused on the care of patients presenting in austere settings with critically ill 'sepsis-like' syndromes. Our approach involves a novel algorithm for comparing mortality among arms without requiring a single fixed control. The algorithm allows poorly-performing arms to be dropped during interim analyses. Consequently, the study may be completed earlier than planned. We used simulation to determine operating characteristics for the trial and to estimate the required sample size. We present a potential study design targeting a minimal effect size of a 23% relative reduction in mortality between any pair of arms. Using estimated power and spurious significance rates from the simulated scenarios, we show that such a trial would require 2550 participants. Over a range of scenarios, our study has 80 to 99% power to select the optimal treatment. Using a fixed control design, if the control arm is least efficacious, 640 subjects would be enrolled into the least efficacious arm, while our algorithm would enroll between 170 and 430. This simulation method can be easily extended to other settings or other binary outcomes. Early dropping of arms is efficient and ethical when conducting clinical trials with multiple arms. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Nonspecific Arm Pain

    Directory of Open Access Journals (Sweden)

    Ali Moradi

    2013-12-01

    Full Text Available Nonspecific activity-related arm pain is characterized by an absence of objective physical findings and symptoms that do not correspond with objective pathophysiology. Arm pain without strict diagnosis is often related to activity, work-related activity in particular, and is often seen in patients with physically demanding work. Psychological factors such as catastrophic thinking, symptoms of depression, and heightened illness concern determine a substantial percentage of the disability associated with puzzling hand and arm pains. Ergonomic modifications can help to control symptoms, but optimal health may require collaborative management incorporating psychosocial and psychological elements of illness.

  7. Nonspecific Arm Pain

    Directory of Open Access Journals (Sweden)

    Ali Moradi

    2013-12-01

    Full Text Available   Nonspecific activity-related arm pain is characterized by an absence of objective physical findings and symptoms that do not correspond with objective pathophysiology. Arm pain without strict diagnosis is often related to activity, work-related activity in particular, and is often seen in patients with physically demanding work. Psychological factors such as catastrophic thinking, symptoms of depression, and heightened illness concern determine a substantial percentage of the disability associated with puzzling hand and arm pains. Ergonomic modifications can help to control symptoms, but optimal health may require collaborative management incorporating psychosocial and psychological elements of illness.

  8. Effects of age, sex and arm on the precision of arm position sense-left-arm superiority in healthy right-handers.

    Science.gov (United States)

    Schmidt, Lena; Depper, Lena; Kerkhoff, Georg

    2013-01-01

    Position sense is an important proprioceptive ability. Disorders of arm position sense (APS) often occur after unilateral stroke, and are associated with a negative functional outcome. In the present study we assessed horizontal APS by measuring angular deviations from a visually defined target separately for each arm in a large group of healthy subjects. We analyzed the accuracy and instability of horizontal APS as a function of age, sex and arm. Subjects were required to specify verbally the position of their unseen arm on a 0-90° circuit by comparing the current position with the target position indicated by a LED lamp, while the arm was passively moved by the examiner. Eighty-seven healthy subjects participated in the study, ranging from 20 to 77 years, subdivided into three age groups. The results revealed that APS was not a function of age or sex, but was significantly better in the non-dominant (left) arm in absolute errors (AE) but not in constant errors (CE) across all age groups of right-handed healthy subjects. This indicates a right-hemisphere superiority for left APS in right-handers and neatly fits to the more frequent and more severe left-sided body-related deficits in patients with unilateral stroke (i.e. impaired APS in left spatial neglect, somatoparaphrenia) or in individuals with abnormalities of the right cerebral hemisphere. These clinical issues will be discussed.

  9. Arms control and disarmament

    International Nuclear Information System (INIS)

    Acton, P.

    1992-01-01

    Article VI of the Non-Proliferation Treaty commits each party to work towards nuclear disarmament and to negotiations to stop the nuclear arms race. All parties to the Treaty are included and a wide range of arms control and disarmament issues are covered. However the main focus at Treaty review conferences has been on nuclear disarmament by the nuclear weapon states which are party to the Treaty. This has led to bilateral United States - Soviet Union negotiations resulting in the Intermediate-range Nuclear Forces Treaty in December 1987 and the Strategic Arms Reduction Treaty (START) in July followed by unilateral arms control measures in September and October 1991. (UK)

  10. Time-Resolved Micro PIV in the Pivoting Area of the Triflo Mechanical Heart Valve.

    Science.gov (United States)

    Vennemann, Bernhard M; Rösgen, Thomas; Carrel, Thierry P; Obrist, Dominik

    2016-09-01

    The Lapeyre-Triflo FURTIVA valve aims at combining the favorable hemodynamics of bioprosthetic heart valves with the durability of mechanical heart valves (MHVs). The pivoting region of MHVs is hemodynamically of special interest as it may be a region of high shear stresses, combined with areas of flow stagnation. Here, platelets can be activated and may form a thrombus which in the most severe case can compromise leaflet mobility. In this study we set up an experiment to replicate the pulsatile flow in the aortic root and to study the flow in the pivoting region under physiological hemodynamic conditions (CO = 4.5 L/min / CO = 3.0 L/min, f = 60 BPM). It was found that the flow velocity in the pivoting region could reach values close to that of the bulk flow during systole. At the onset of diastole the three valve leaflets closed in a very synchronous manner within an average closing time of 55 ms which is much slower than what has been measured for traditional bileaflet MHVs. Hot spots for elevated viscous shear stresses were found at the flanges of the housing and the tips of the leaflet ears. Systolic VSS was maximal during mid-systole and reached levels of up to 40 Pa.

  11. [Shushu (ancient Chinese numerology) in Lingshu: Gudu (Miraculous Pivot: Bone-Length Measurement)].

    Science.gov (United States)

    Zhuo, Lian-Shi

    2010-10-01

    Lingshu: Gudu (Miraculous Pivot: Bone-Length Measurement) is compared with literatures concerning the Shushu (ancient Chinese numerology) of the Qin Dynasty (221 B. C. - 206 B. C. ) and the Han Dynasty (206 B. C.-220 A. D.) in this article. And it is discovered that "the number of heaven and earth" in Yijing (The Book of Change) was implied in the bone-length measurement. The theory of Shushu is hidden in the sized of head, neck, chest, abdomen, back and 4 extremities according to the measurement. The meaning of establishment of bone-length measurement, which is found to have universality, laid in setting down the measurement of meridians. And it is the origin of the proportional measurement of locating acupoints. Checked with the theory of Shushu, errors in the description of bone-length measurement could also be found in Lingshu: Gudu (Miraculous Pivot: Bone-Length Measurement) of the present edition, which is helpful for the modern study on the measurement.

  12. Wave energy, lever operated pivoting float LOPF study

    Energy Technology Data Exchange (ETDEWEB)

    Margheritini, L.

    2012-11-01

    The fully instrumented Resen Waves Lever Operated Pivoting Float LOPF wave energy buoy model has gone through the first stage of testing in regular waves in scale 1:25 of the North Sea wave conditions, in the 3D deep wave basin at the Hydraulic and Coastal Engineering Laboratory of Aalborg University in Denmark. The model size was 60cm W x 90cm L x 21cm H. The 60 cm width pointed towards the wave front. The LOPF buoy is characterized by a simple mechanical design with few moving parts and direct electrical output and it is taut moored to the sea bed, so all forces are referenced to the seabed for maximum energy output in regular as well as irregular waves. During storms the buoy pivots and streamlines itself to minimize loads on the mooring line. A conservative estimate shows that a full scale system for North Sea conditions has a float size width of 15 m that will, with 60% generator efficiency, produce 610 MWh/y (609.497 kWh/y) with an average power output of 69.6 kW, which requires a generator capacity of 700 kW. It is expected the generator efficiency can be increased to 90% in the future. More specific calculations (from EnergiNet) show that with one generator of 695 kW the expected power production is 585 MWh/y; with a generator of 250 kW and 100 kW, the expected power production is 481 MWh/y and 182 MWh/y respectively. In addition there are several areas for future improvements for increased power production. (Author)

  13. Understanding the conventional arms trade

    Science.gov (United States)

    Stohl, Rachel

    2017-11-01

    The global conventional arms trade is worth tens of billions of dollars every year and is engaged in by every country in the world. Yet, it is often difficult to control the legal trade in conventional arms and there is a thriving illicit market, willing to arm unscrupulous regimes and nefarious non-state actors. This chapter examines the international conventional arms trade, the range of tools that have been used to control it, and challenges to these international regimes.

  14. Student measurement of blood pressure using a simulator arm compared with a live subject's arm.

    Science.gov (United States)

    Lee, Jennifer J; Sobieraj, Diana M; Kuti, Effie L

    2010-06-15

    To compare accuracy of blood pressure measurements using a live subject and a simulator arm, and to determine students' preferences regarding measurement. This was a crossover study comparing blood pressure measurements from a live subject and a simulator arm. Students completed an anonymous survey instrument defining opinions on ease of measurement. Fifty-seven students completed blood pressure measurements on live subjects while 72 students completed blood pressure measurements using the simulator arm. There were no significant systematic differences between the 2 measurement techniques. Systolic blood pressure measurements from a live subject arm were less likely to be within 4 mm Hg compared with measurements of a simulator arm. Diastolic blood pressure measurements were not significantly different between the 2 techniques. Accuracy of student measurement of blood pressure using a simulator arm was similar to the accuracy with a live subject. There was no difference in students' preferences regarding measurement techniques.

  15. Borehole tool outrigger arm displacement control mechanism

    International Nuclear Information System (INIS)

    Lee, A.G.

    1985-01-01

    As the outrigger arms of a borehole logging tool are flexed inwardly and outwardly according to the diameter of the borehole opening through which they pass, the corresponding axial displacements of the ends of the arms are controlled to determine the axial positions of the arms relative to the tool. Specifically, as the arm ends move, they are caused to rotate by a cam mechanism. The stiffness of the arms causes the arm ends to rotate in unison, and the exact positions of the arms on the tool are then controlled by the differential movements of the arm ends in the cams

  16. Nonparetic arm force does not overinhibit the paretic arm in chronic poststroke hemiparesis.

    Science.gov (United States)

    Dimyan, Michael A; Perez, Monica A; Auh, Sungyoung; Tarula, Erick; Wilson, Matthew; Cohen, Leonardo G

    2014-05-01

    To determine whether nonparetic arm force overinhibits the paretic arm in patients with chronic unilateral poststroke hemiparesis. Case-control neurophysiological and behavioral study of patients with chronic stroke. Research institution. Eighty-six referred patients were screened to enroll 9 participants (N=9) with a >6 month history of 1 unilateral ischemic infarct that resulted in arm hemiparesis with residual ability to produce 1Nm of wrist flexion torque and without contraindication to transcranial magnetic stimulation. Eight age- and handedness-matched healthy volunteers without neurologic diagnosis were studied for comparison. Not applicable. Change in interhemispheric inhibition targeting the ipsilesional primary motor cortex (M1) during nonparetic arm force. We hypothesized that interhemispheric inhibition would increase more in healthy controls than in patients with hemiparesis. Healthy age-matched controls had significantly greater increases in inhibition from their active to resting M1 than patients with stroke from their active contralesional to resting ipsilesional M1 in the same scenario (20%±7% vs -1%±4%, F1,12=6.61, P=.025). Patients with greater increases in contralesional to ipsilesional inhibition were better performers on the 9-hole peg test of paretic arm function. Our findings reveal that producing force with the nonparetic arm does not necessarily overinhibit the paretic arm. Though our study is limited in generalizability by the small sample size, we found that greater active contralesional to resting ipsilesional M1 inhibition was related with better recovery in this subset of patients with chronic poststroke. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  17. Combined reconstruction of the anterior cruciate ligament associated with anterolateral tenodesis effectively controls the acceleration of the tibia during the pivot shift.

    Science.gov (United States)

    Hardy, Alexandre; Casabianca, Laurent; Hardy, Edouard; Grimaud, Olivier; Meyer, Alain

    2017-04-01

    The pivot shift test is quantified subjectively during assessment of patients presenting with suspected Anterior Cruciate Ligament (ACL) tears and has a low interobserver reproducibility. The Kinematic Rapid Assessment (KiRA) is a triaxial accelerometer that makes it possible to non-invasively quantify tibial acceleration during the pivot shift test. Abolishing pivot shift is considered to be a key element in surgical reconstruction but is incomplete in 25-38% of patients. Patients were included prospectively. Inclusion criteria were patients requiring ACL reconstruction associated with at least one of the following factors corresponding to the patient who have a high risk of rupture either by their sports activity, a failure case, or the notion of important rotational laxity: the patient practiced a competitive pivot-contact sport, revision ACL reconstruction (besides STG (semitendinosus-gracilis graft) repair), subjective explosive rotational laxity, Segond fracture, and TELOS value of >10 mm. Standardized pre- and postoperative pivot shift tests were immediately performed under anesthesia in both knees. Forty-three patients were included. Mean preoperative variations in tibial acceleration in the healthy and injured knees were 1.2 ± 0.1 and 2.7 ± 0.3 m/s 2 , respectively, p operated knees (n.s). Combined ACL reconstruction associated with anterolateral tenodesis suppress acute pathologic tibial acceleration in the pivot shift. III.

  18. Nature of galaxy spiral arms

    International Nuclear Information System (INIS)

    Efremov, Yu.N.

    1984-01-01

    The nature of galaxy spiral arms is discussed in a popular form. Two approaches in the theory of spiral arms are considered; they are related to the problem of differential galaxy rotation and the spiral structure wave theory. The example of Galaxy M31 is considered to compare the structural peculiarity of its spiral arms with the wave theory predictions. The situation in the central and south-eastern part of arm S4 in Galaxy M31 noted to be completely explained by the wave theory and modern concepts on the origin of massive stars

  19. Arms races between and within species.

    Science.gov (United States)

    Dawkins, R; Krebs, J R

    1979-09-21

    An adaptation in one lineage (e.g. predators) may change the selection pressure on another lineage (e.g. prey), giving rise to a counter-adaptation. If this occurs reciprocally, an unstable runaway escalation or 'arms race' may result. We discuss various factors which might give one side an advantage in an arms race. For example, a lineage under strong selection may out-evolve a weakly selected one (' the life-dinner principle'). We then classify arms races in two independent ways. They may be symmetric or asymmetric, and they may be interspecific or intraspecific. Our example of an asymmetric interspecific arms race is that between brood parasites and their hosts. The arms race concept may help to reduce the mystery of why cuckoo hosts are so good at detecting cuckoo eggs, but so bad at detecting cuckoo nestlings. The evolutionary contest between queen and worker ants over relative parental investment is a good example of an intraspecific asymmetric arms race. Such cases raise special problems because the participants share the same gene pool. Interspecific symmetric arms races are unlikely to be important, because competitors tend to diverge rather than escalate competitive adaptations. Intraspecific symmetric arms races, exemplified by adaptations for male-male competition, may underlie Cope's Rule and even the extinction of lineages. Finally we consider ways in which arms races can end. One lineage may drive the other to extinction; one may reach an optimum, thereby preventing the other from doing so; a particularly interesting possibility, exemplified by flower-bee coevolution, is that both sides may reach a mutual local optimum; lastly, arms races may have no stable and but may cycle continuously. We do not wish necessarily to suggest that all, or even most, evolutionary change results from arms races, but we do suggest that the arms race concept may help to resolve three long-standing questions in evolutionary theory.

  20. JPRS Report Arms Control

    National Research Council Canada - National Science Library

    1993-01-01

    Table of Contents: (1) COMMONWEALTH OF INDEPENDENT STATES - (A) GENERAL Flaws in U.S.-Russian SSD Agreement Viewed, Khariton - Espionage Not Crucial in Soviet Nuclear Arms Development, Further on Espionage Role in Nuclear Arms Projects...

  1. Organization of octopus arm movements: a model system for studying the control of flexible arms.

    Science.gov (United States)

    Gutfreund, Y; Flash, T; Yarom, Y; Fiorito, G; Segev, I; Hochner, B

    1996-11-15

    Octopus arm movements provide an extreme example of controlled movements of a flexible arm with virtually unlimited degrees of freedom. This study aims to identify general principles in the organization of these movements. Video records of the movements of Octopus vulgaris performing the task of reaching toward a target were studied. The octopus extends its arm toward the target by a wave-like propagation of a bend that travels from the base of the arm toward the tip. Similar bend propagation is seen in other octopus arm movements, such as locomotion and searching. The kinematics (position and velocity) of the midpoint of the bend in three-dimensional space were extracted using the direct linear transformation algorithm. This showed that the bend tends to move within a single linear plane in a simple, slightly curved path connecting the center of the animal's body with the target location. Approximately 70% of the reaching movements demonstrated a stereotyped tangential velocity profile. An invariant profile was observed when movements were normalized for velocity and distance. Two arms, extended together in the same behavioral context, demonstrated identical velocity profiles. The stereotyped features of the movements were also observed in spontaneous arm extensions (not toward an external target). The simple and stereotypic appearance of the bend trajectory suggests that the position of the bend in space and time is the controlled variable. We propose that this strategy reduces the immense redundancy of the octopus arm movements and hence simplifies motor control.

  2. High precision detector robot arm system

    Science.gov (United States)

    Shu, Deming; Chu, Yong

    2017-01-31

    A method and high precision robot arm system are provided, for example, for X-ray nanodiffraction with an X-ray nanoprobe. The robot arm system includes duo-vertical-stages and a kinematic linkage system. A two-dimensional (2D) vertical plane ultra-precision robot arm supporting an X-ray detector provides positioning and manipulating of the X-ray detector. A vertical support for the 2D vertical plane robot arm includes spaced apart rails respectively engaging a first bearing structure and a second bearing structure carried by the 2D vertical plane robot arm.

  3. Algorithms for Unequal-Arm Michelson Interferometers

    Science.gov (United States)

    Giampieri, Giacomo; Hellings, Ronald W.; Tinto, Massimo; Bender, Peter L.; Faller, James E.

    1994-01-01

    A method of data acquisition and data analysis is described in which the performance of Michelson-type interferometers with unequal arms can be made nearly the same as interferometers with equal arms. The method requires a separate readout of the relative phase in each arm, made by interfering the returning beam in each arm with a fraction of the outgoing beam.

  4. Apparatus for connecting an element attached to a metallic wire to an interior tube in a core drill

    Energy Technology Data Exchange (ETDEWEB)

    1970-04-17

    A locking device consists of at least one lever pivotable around an axis transversal to the axis of the core drill and mounted on the upper end of the core tube. A first arm oriented upward is intended to pivot during lowering of the wire line and to engage on the core tube, so that the core tube can be lifted by the wire line. A second arm prevents lifting of the core tube during drilling. The second arm also releases the core tube, after the wire line has been firmly attached and locked onto the core tube.

  5. FY1995 development of artificial arm 'SMART ARM' by spherical ultrasonic motor; 1995 nendo kyumen choonpa motor wo mochiita jinko gishu smart arm no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The project has an intention of development of new type artificial arm by spherical ultrasonic motor. We have succeeded in developing new type of spherical ultrasonic motor with three DOF. And we have succeeded in applying the motor to an artificial arm. This arm have advantages of small size, low weight torque comparing with conventional ones. We demonstrated them the new arm behaved well and it had good controlabilty. (NEDO)

  6. Average Case Analysis of Java 7's Dual Pivot Quicksort

    OpenAIRE

    Wild, Sebastian; Nebel, Markus E.

    2013-01-01

    Recently, a new Quicksort variant due to Yaroslavskiy was chosen as standard sorting method for Oracle's Java 7 runtime library. The decision for the change was based on empirical studies showing that on average, the new algorithm is faster than the formerly used classic Quicksort. Surprisingly, the improvement was achieved by using a dual pivot approach, an idea that was considered not promising by several theoretical studies in the past. In this paper, we identify the reason for this unexpe...

  7. Octopus-inspired multi-arm robotic swimming.

    Science.gov (United States)

    Sfakiotakis, M; Kazakidi, A; Tsakiris, D P

    2015-05-13

    The outstanding locomotor and manipulation characteristics of the octopus have recently inspired the development, by our group, of multi-functional robotic swimmers, featuring both manipulation and locomotion capabilities, which could be of significant engineering interest in underwater applications. During its little-studied arm-swimming behavior, as opposed to the better known jetting via the siphon, the animal appears to generate considerable propulsive thrust and rapid acceleration, predominantly employing movements of its arms. In this work, we capture the fundamental characteristics of the corresponding complex pattern of arm motion by a sculling profile, involving a fast power stroke and a slow recovery stroke. We investigate the propulsive capabilities of a multi-arm robotic system under various swimming gaits, namely patterns of arm coordination, which achieve the generation of forward, as well as backward, propulsion and turning. A lumped-element model of the robotic swimmer, which considers arm compliance and the interaction with the aquatic environment, was used to study the characteristics of these gaits, the effect of various kinematic parameters on propulsion, and the generation of complex trajectories. This investigation focuses on relatively high-stiffness arms. Experiments employing a compliant-body robotic prototype swimmer with eight compliant arms, all made of polyurethane, inside a water tank, successfully demonstrated this novel mode of underwater propulsion. Speeds of up to 0.26 body lengths per second (approximately 100 mm s(-1)), and propulsive forces of up to 3.5 N were achieved, with a non-dimensional cost of transport of 1.42 with all eight arms and of 0.9 with only two active arms. The experiments confirmed the computational results and verified the multi-arm maneuverability and simultaneous object grasping capability of such systems.

  8. Pivot design in bileaflet valves.

    Science.gov (United States)

    Vallana, F; Rinaldi, S; Galletti, P M; Nguyen, A; Piwnica, A

    1992-01-01

    The design criteria leading to the development of a new bileaflet valve (Sorin Bicarbon) were derived from the analysis of functional requirements, the performance of existing prostheses, and the availability of an advanced carbon coating technology (Carbofilm). The hinge is the critical element affecting fluid dynamics, durability, and thrombus formation in bileaflet valves. A comparative study of three existing models led to a new hinge design that was based on coupling two spheric surfaces with different radii of curvature (leaflet pivot and hinge recess) and obtained by electroerosion into a Carbofilm-coated metallic housing. In this valve, the point of contact moves continuously by rolling, not sliding. This minimizes friction and wear and allows uninterrupted washing of the blood exposed surfaces even during diastole (a finding established in patients using transesophageal echocardiography). Tricuspid implantation without anticoagulation in 33 sheep did not lead to thrombotic events (follow-up, 40-400 days). In the first 36 clinical implants observed for 15 months (mitral position, size 29; two unrelated deaths), the mean diastolic gradient by echo Doppler was 4 +/- 1.25 mmHg; the functional area was 3.2 +/- 0.6 cm2. No leaflet fracture and no thrombotic or embolic complications were observed clinically using a standard anticoagulant regimen.

  9. Security and arms control

    International Nuclear Information System (INIS)

    Kolodziej, E.A.; Morgan, P.M.

    1989-01-01

    This book attempts to clarify and define selected current issues and problems related to security and arms control from an international perspective. The chapters are organized under the following headings. Conflict and the international system, Nuclear deterrence, Conventional warfare, Subconventional conflict, Arms control and crisis management

  10. Version of the galaxy spiral structure model with opposite-directed arms and inter-arm links

    Energy Technology Data Exchange (ETDEWEB)

    Dolidze, M V [AN Gruzinskoj SSR, Abastumani. Abastumanskaya Astrofizicheskaya Observatoriya

    1963-05-01

    An attempt is made to explain some peculiarities of the local spiral structure and large-scale distribution of HII regions in the Galaxy by coexistence of the trailing and leading arm systems of different power and development. The existence of opposite-directed arms and inter-arm links in the circular zone (5-15 kpc) is analysed from the point of view of different Galaxy models.

  11. Development of computer tablet software for clinical quantification of lateral knee compartment translation during the pivot shift test.

    Science.gov (United States)

    Muller, Bart; Hofbauer, Marcus; Rahnemai-Azar, Amir Ata; Wolf, Megan; Araki, Daisuke; Hoshino, Yuichi; Araujo, Paulo; Debski, Richard E; Irrgang, James J; Fu, Freddie H; Musahl, Volker

    2016-01-01

    The pivot shift test is a commonly used clinical examination by orthopedic surgeons to evaluate knee function following injury. However, the test can only be graded subjectively by the examiner. Therefore, the purpose of this study is to develop software for a computer tablet to quantify anterior translation of the lateral knee compartment during the pivot shift test. Based on the simple image analysis method, software for a computer tablet was developed with the following primary design constraint - the software should be easy to use in a clinical setting and it should not slow down an outpatient visit. Translation of the lateral compartment of the intact knee was 2.0 ± 0.2 mm and for the anterior cruciate ligament-deficient knee was 8.9 ± 0.9 mm (p software provides reliable, objective, and quantitative data on translation of the lateral knee compartment during the pivot shift test and meets the design constraints posed by the clinical setting.

  12. Spiral-arm instability: giant clump formation via fragmentation of a galactic spiral arm

    Science.gov (United States)

    Inoue, Shigeki; Yoshida, Naoki

    2018-03-01

    Fragmentation of a spiral arm is thought to drive the formation of giant clumps in galaxies. Using linear perturbation analysis for self-gravitating spiral arms, we derive an instability parameter and define the conditions for clump formation. We extend our analysis to multicomponent systems that consist of gas and stars in an external potential. We then perform numerical simulations of isolated disc galaxies with isothermal gas, and compare the results with the prediction of our analytic model. Our model describes accurately the evolution of the spiral arms in our simulations, even when spiral arms dynamically interact with one another. We show that most of the giant clumps formed in the simulated disc galaxies satisfy the instability condition. The clump masses predicted by our model are in agreement with the simulation results, but the growth time-scale of unstable perturbations is overestimated by a factor of a few. We also apply our instability analysis to derive scaling relations of clump properties. The expected scaling relation between the clump size, velocity dispersion, and circular velocity is slightly different from that given by the Toomre instability analyses, but neither is inconsistent with currently available observations. We argue that the spiral-arm instability is a viable formation mechanism of giant clumps in gas-rich disc galaxies.

  13. Robotic In-Situ Surface Exploration System (RISES)

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's Asteroid Redirect Mission (ARM) is a pivotal and daring approach that will mature multiple technologies for future deep space exploration. ARM seeks to...

  14. A Generalized Pivotal Quantity Approach to Analytical Method Validation Based on Total Error.

    Science.gov (United States)

    Yang, Harry; Zhang, Jianchun

    2015-01-01

    The primary purpose of method validation is to demonstrate that the method is fit for its intended use. Traditionally, an analytical method is deemed valid if its performance characteristics such as accuracy and precision are shown to meet prespecified acceptance criteria. However, these acceptance criteria are not directly related to the method's intended purpose, which is usually a gurantee that a high percentage of the test results of future samples will be close to their true values. Alternate "fit for purpose" acceptance criteria based on the concept of total error have been increasingly used. Such criteria allow for assessing method validity, taking into account the relationship between accuracy and precision. Although several statistical test methods have been proposed in literature to test the "fit for purpose" hypothesis, the majority of the methods are not designed to protect the risk of accepting unsuitable methods, thus having the potential to cause uncontrolled consumer's risk. In this paper, we propose a test method based on generalized pivotal quantity inference. Through simulation studies, the performance of the method is compared to five existing approaches. The results show that both the new method and the method based on β-content tolerance interval with a confidence level of 90%, hereafter referred to as the β-content (0.9) method, control Type I error and thus consumer's risk, while the other existing methods do not. It is further demonstrated that the generalized pivotal quantity method is less conservative than the β-content (0.9) method when the analytical methods are biased, whereas it is more conservative when the analytical methods are unbiased. Therefore, selection of either the generalized pivotal quantity or β-content (0.9) method for an analytical method validation depends on the accuracy of the analytical method. It is also shown that the generalized pivotal quantity method has better asymptotic properties than all of the current

  15. Poly(glycolide multi-arm star polymers: Improved solubility via limited arm length

    Directory of Open Access Journals (Sweden)

    Florian K. Wolf

    2010-06-01

    Full Text Available Due to the low solubility of poly(glycolic acid (PGA, its use is generally limited to the synthesis of random copolyesters with other hydroxy acids, such as lactic acid, or to applications that permit direct processing from the polymer melt. Insolubility is generally observed for PGA when the degree of polymerization exceeds 20. Here we present a strategy that allows the preparation of PGA-based multi-arm structures which significantly exceed the molecular weight of processable oligomeric linear PGA (<1000 g/mol. This was achieved by the use of a multifunctional hyperbranched polyglycerol (PG macroinitiator and the tin(II-2-ethylhexanoate catalyzed ring-opening polymerization of glycolide in the melt. With this strategy it is possible to combine high molecular weight with good molecular weight control (up to 16,000 g/mol, PDI = 1.4–1.7, resulting in PGA multi-arm star block copolymers containing more than 90 wt % GA. The successful linkage of PGA arms and PG core via this core first/grafting from strategy was confirmed by detailed NMR and SEC characterization. Various PG/glycolide ratios were employed to vary the length of the PGA arms. Besides fluorinated solvents, the materials were soluble in DMF and DMSO up to an average arm length of 12 glycolic acid units. Reduction in the Tg and the melting temperature compared to the homopolymer PGA should lead to simplified processing conditions. The findings contribute to broadening the range of biomedical applications of PGA.

  16. Integration of wireless sensor networks into automatic irrigation scheduling of a center pivot

    Science.gov (United States)

    A six-span center pivot system was used as a platform for testing two wireless sensor networks (WSN) of infrared thermometers. The cropped field was a semi-circle, divided into six pie shaped sections of which three were irrigated manually and three were irrigated automatically based on the time tem...

  17. Automated generation of massive image knowledge collections using Microsoft Live Labs Pivot to promote neuroimaging and translational research.

    Science.gov (United States)

    Viangteeravat, Teeradache; Anyanwu, Matthew N; Ra Nagisetty, Venkateswara; Kuscu, Emin

    2011-07-15

    Massive datasets comprising high-resolution images, generated in neuro-imaging studies and in clinical imaging research, are increasingly challenging our ability to analyze, share, and filter such images in clinical and basic translational research. Pivot collection exploratory analysis provides each user the ability to fully interact with the massive amounts of visual data to fully facilitate sufficient sorting, flexibility and speed to fluidly access, explore or analyze the massive image data sets of high-resolution images and their associated meta information, such as neuro-imaging databases from the Allen Brain Atlas. It is used in clustering, filtering, data sharing and classifying of the visual data into various deep zoom levels and meta information categories to detect the underlying hidden pattern within the data set that has been used. We deployed prototype Pivot collections using the Linux CentOS running on the Apache web server. We also tested the prototype Pivot collections on other operating systems like Windows (the most common variants) and UNIX, etc. It is demonstrated that the approach yields very good results when compared with other approaches used by some researchers for generation, creation, and clustering of massive image collections such as the coronal and horizontal sections of the mouse brain from the Allen Brain Atlas. Pivot visual analytics was used to analyze a prototype of dataset Dab2 co-expressed genes from the Allen Brain Atlas. The metadata along with high-resolution images were automatically extracted using the Allen Brain Atlas API. It is then used to identify the hidden information based on the various categories and conditions applied by using options generated from automated collection. A metadata category like chromosome, as well as data for individual cases like sex, age, and plan attributes of a particular gene, is used to filter, sort and to determine if there exist other genes with a similar characteristics to Dab2. And

  18. An approach to evaluate capacitance, capacitive reactance and resistance of pivoted pads of a thrust bearing

    Science.gov (United States)

    Prashad, Har

    1992-07-01

    A theoretical approach is developed for determining the capacitance and active resistance between the interacting surfaces of pivoted pads and thrust collar, under different conditions of operation. It is shown that resistance and capacitive reactance of a thrust bearing decrease with the number of pads times the values of these parameters for an individual pad, and that capacitance increases with the number of pads times the capacitance of an individual pad. The analysis presented has a potential to diagnose the behavior of pivoted pad thrust bearings with the angle of tilt and the ratio of film thickness at the leading to trailing edge, by determining the variation of capacitance, resistance, and capacitive reactance.

  19. Motion and Stress Analysis of Cam System for Marine Diesel Engine 93 KW

    Directory of Open Access Journals (Sweden)

    Christian Dhani Setiawan

    2017-01-01

    Full Text Available The developments of maritime sector in Indonesia shows increasing demand for ships. Especially ships with size of 30 GT has problem with low availability of the ship engine, which most of the ships still use non marine diesel engine as its main propulsion. The problem gives interest to make a step to improve by design marine diesel engine using reverse engineering method. Cam system of marine diesel engine design was needed to be calculate to select the material and the motion. The design of cam system needs study about the stress analysis in cam system to make sure the distribution of force and moment. The result of stress analysis was used to select material of components in cam system. The motion analysis result was used to be input data of stress analysis. The condition to obtain the stress of components was on maximum condition, its contain pressure, torque, rotation, and force. All component that calculated are camshaft, lifter (flat-tappet, push rod, rocker arm, spring, and valve. Each component was given two different materials and material selection was based on safety factor of each component. Material for camshaft and lifter were malleable cast iron, for push rod and rocker arm were mild steel, for spring was ASTM A231, for intake valve was steel JIS SUH3, and for exhaust valve was steel JIS SUH35. The result of motion analysis were angular velocity of camshaft with value was 2400 deg/sec, friction force between camshaft and lifter with maximum value was 125.393 N, and contact force between camshaft and lifter with maximum value was 845.307 N, and linear velocity of intake valve with maximum value was 696.573 mm/s, and linear velocity of exhaust valve was 463.734 mm/s.

  20. Comparison of treatment effect sizes from pivotal and postapproval trials of novel therapeutics approved by the FDA based on surrogate markers of disease: a meta-epidemiological study.

    Science.gov (United States)

    Wallach, Joshua D; Ciani, Oriana; Pease, Alison M; Gonsalves, Gregg S; Krumholz, Harlan M; Taylor, Rod S; Ross, Joseph S

    2018-03-21

    The U.S. Food and Drug Administration (FDA) often approves new drugs based on trials that use surrogate markers for endpoints, which involve certain trade-offs and may risk making erroneous inferences about the medical product's actual clinical effect. This study aims to compare the treatment effects among pivotal trials supporting FDA approval of novel therapeutics based on surrogate markers of disease with those observed among postapproval trials for the same indication. We searched Drugs@FDA and PubMed to identify published randomized superiority design pivotal trials for all novel drugs initially approved by the FDA between 2005 and 2012 based on surrogate markers as primary endpoints and published postapproval trials using the same surrogate markers or patient-relevant outcomes as endpoints. Summary ratio of odds ratios (RORs) and difference between standardized mean differences (dSMDs) were used to quantify the average difference in treatment effects between pivotal and matched postapproval trials. Between 2005 and 2012, the FDA approved 88 novel drugs for 90 indications based on one or multiple pivotal trials using surrogate markers of disease. Of these, 27 novel drugs for 27 indications were approved based on pivotal trials using surrogate markers as primary endpoints that could be matched to at least one postapproval trial, for a total of 43 matches. For nine (75.0%) of the 12 matches using the same non-continuous surrogate markers as trial endpoints, pivotal trials had larger treatment effects than postapproval trials. On average, treatment effects were 50% higher (more beneficial) in the pivotal than the postapproval trials (ROR 1.5; 95% confidence interval CI 1.01-2.23). For 17 (54.8%) of the 31 matches using the same continuous surrogate markers as trial endpoints, pivotal trials had larger treatment effects than the postapproval trials. On average, there was no difference in treatment effects between pivotal and postapproval trials (dSMDs 0.01; 95

  1. How can push-off be preserved during use of an ankle foot orthosis in children with hemiplegia? A prospective controlled study.

    Science.gov (United States)

    Desloovere, Kaat; Molenaers, Guy; Van Gestel, Leen; Huenaerts, Catherine; Van Campenhout, Anja; Callewaert, Barbara; Van de Walle, Patricia; Seyler, J

    2006-10-01

    Several studies indicated that walking with an ankle foot orthosis (AFO) impaired third rocker. The purpose of this study was to evaluate the effects of two types of orthoses, with similar goal settings, on gait, in a homogeneous group of children, using both barefoot and shoe walking as control conditions. Fifteen children with hemiplegia, aged between 4 and 10 years, received two types of individually tuned AFOs: common posterior leaf-spring (PLS) and Dual Carbon Fiber Spring AFO (CFO) (with carbon fibre at the dorsal part of the orthosis). Both orthoses were expected to prevent plantar flexion, thus improving first rocker, allowing dorsiflexion to improve second rocker, absorbing energy during second rocker, and returning it during the third rocker. The effect of the AFOs was studied using objective gait analysis, including 3D kinematics, and kinetics in four conditions: barefoot, shoes without AFO, and PLS and CFO combined with shoes. Several gait parameters significantly changed in shoe walking compared to barefoot walking (cadence, ankle ROM and velocity, knee shock absorption, and knee angle in swing). The CFO produced a significantly larger ankle ROM and ankle velocity during push-off, and an increased plantar flexion moment and power generation at pre-swing compared to the PLS (<0.01). The results of this study further support the findings of previous studies indicating that orthoses improve specific gait parameters compared to barefoot walking (velocity, step length, first and second ankle rocker, sagittal knee and hip ROM). However, compared to shoes, not all improvements were statistically significant.

  2. Design charts for arbitrarily pivoted, liquid-lubricated flat-sector-pad thrust bearing

    Science.gov (United States)

    Etsion, I.

    1977-01-01

    A flat, sector-shaped geometry for a liquid-lubricated thrust bearing is analyzed considering both the pitch and roll of the pad. Results are presented in design charts that enable a direct approach to the design of point- and line-pivoted, tilting pad bearings. A comparison is made with the Mitchell bearing approximation and it is found that this approximation always overestimates load capacity.

  3. Arm Volumetry Versus Upper Extremity Lymphedema Index: Validity of Upper Extremity Lymphedema Index for Body-Type Corrected Arm Volume Evaluation.

    Science.gov (United States)

    Yamamoto, Nana; Yamamoto, Takumi; Hayashi, Nobuko; Hayashi, Akitatsu; Iida, Takuya; Koshima, Isao

    2016-06-01

    Volumetry, measurement of extremity volume, is a commonly used method for upper extremity lymphedema (UEL) evaluation. However, comparison between different patients with different physiques is difficult with volumetry, because body-type difference greatly affects arm volume. Seventy arms of 35 participants who had no history of arm edema or breast cancer were evaluated. Arm volume was calculated using a summed truncated cone model, and UEL index was calculated using circumferences and body mass index (BMI). Examinees' BMI was classified into 3 groups, namely, low BMI (BMI, 25 kg/m). Arm volume and UEL index were compared with corresponding BMI groups. Mean (SD) arm volume was 1090.9 (205.5) mL, and UEL index 96.9 (5.6). There were significant differences in arm volume between BMI groups [low BMI vs middle BMI vs high BMI, 945.2 (107.4) vs 1045.2 (87.5) vs 1443.1 (244.4) mL, P 0.5]. Arm volume significantly increased with increase of BMI, whereas UEL index stayed constant regardless of BMI. Upper extremity lymphedema index would allow better body-type corrected arm volume evaluation compared with arm volumetry.

  4. Modernization of African Armed Forces

    DEFF Research Database (Denmark)

    Mandrup, Thomas

    2015-01-01

    Concept paper framing the debate at the Dakar Forum Workshop on Modernization of Armed forces in Africa.......Concept paper framing the debate at the Dakar Forum Workshop on Modernization of Armed forces in Africa....

  5. Critical current scaling and the pivot-point in Nb3Sn strands

    International Nuclear Information System (INIS)

    Tsui, Y; Hampshire, D P

    2012-01-01

    Detailed measurements are provided of the engineering critical current density (J c ) and the index of transition (n-value) of two different types of advanced ITER Nb 3 Sn superconducting strand for fusion applications. The samples consist of one internal-tin strand (OST) and two bronze-route strands (BEAS I and BEAS II—reacted using different heat treatments). Tests on different sections of these wires show that prior to applying strain, J c is homogeneous to better than 2% along the length of each strand. J c data have been characterized as a function of magnetic field (B ≤ 14.5 T), temperature (4.2 K ≤ T ≤ 12 K) and applied axial strain ( − 1% ≤ ε A ≤ 0.8%). Strain-cycling tests demonstrate that the variable strain J c data are reversible to better than 2% when the applied axial strain is in the range of − 1% ≤ ε A ≤ 0.5%. The wires are damaged when the intrinsic strain (ε I ) is ε I ≥ 0.55% and ε I ≥ 0.23% for the OST and BEAS strands, respectively. The strain dependences of the normalized J c for each type of strand are similar to those of prototype strands of similar design measured in 2005 and 2008 to about 2% which makes them candidate strands for a round-robin interlaboratory comparison. The J c data are described by Durham, ITER and Josephson-junction parameterizations to an accuracy of about 4%. For all of these scaling laws, the percentage difference between the data and the parameterization is larger when J c is small, caused by high B, T or |ε I |. The n-values can be described by a modified power law of the form n=1+rI c s , where r and s are approximately constant and I c is the critical current. It has long been known that pivot-points (or cross-overs) in J c occur at high magnetic field and temperature. Changing the magnetic field or temperature from one side of the pivot-point to the other changes the highest J c sample to the lowest J c sample and vice versa. The pivot-point follows the B–T phase boundary

  6. 21 CFR 890.3640 - Arm sling.

    Science.gov (United States)

    2010-04-01

    ... arm sling is a device intended for medical purposes to immobilize the arm, by means of a fabric band... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arm sling. 890.3640 Section 890.3640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES...

  7. Blood pressure measurement: one arm or both arm?

    Science.gov (United States)

    Kulkarni, Prasad K; Shekhar, Susheela; Reddy, B N; Nirmala, B C

    2011-09-01

    Guidelines for measuring blood pressure includes measurement of blood pressure on both arms but it is often ignored. Our case report aims at highlighting the need follow the guidelines. A 60 year old 59 kg weighing male asymptomatic patient without any comobidities was posted for bilateral inguinal hernia repair. The interarm blood pressure difference was discovered incidentally during his preanaesthetic evalution. On further evaluation patient was found to be having subclavian stenosis on left side which was asymptomatic. Intraoperative and post operative period was uneventful. Blood pressure measurement should be done in accordance with the stipulated guidelines. Inter arm blood pressure difference should be noted in all patients as not only for diagnosis and treatment of hypertension but also as a tool to diagnose asymptomatic peripheral vascular disesase.

  8. Novel and successful free comments method for sensory characterization of chocolate ice cream: A comparative study between pivot profile and comment analysis.

    Science.gov (United States)

    Fonseca, Fernando G A; Esmerino, Erick A; Filho, Elson R Tavares; Ferraz, Juliana P; da Cruz, Adriano G; Bolini, Helena M A

    2016-05-01

    Rapid sensory profiling methods have gained space in the sensory evaluation field. Techniques using direct analysis of the terms generated by consumers are considered easy to perform, without specific training requirements, thus improving knowledge about consumer perceptions on various products. This study aimed to determine the sensory profile of different commercial samples of chocolate ice cream, labeled as conventional and light or diet, using the "comment analysis" and "pivot profile" methods, based on consumers' perceptions. In the comment analysis task, consumers responded to 2 separate open questions describing the sensory attributes they liked or disliked in each sample. In the pivot profile method, samples were served in pairs (consisting of a coded sample and pivot), and consumers indicated the higher and lower intensity attributes in the target sample compared with the pivot. We observed that both methods were able to characterize the different chocolate ice cream samples using consumer perception, with high correlation results and configurational similarity (regression vector coefficient=0.917) between them. However, it is worth emphasizing that comment analysis is performed intuitively by consumers, whereas the pivot profile method showed high analytical and discriminative power even using consumers, proving to be a promising technique for routine application when classical descriptive methods cannot be used. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  9. ARM assembly language with hardware experiments

    CERN Document Server

    Elahi, Ata

    2015-01-01

    This book provides a hands-on approach to learning ARM assembly language with the use of a TI microcontroller. The book starts with an introduction to computer architecture and then discusses number systems and digital logic. The text covers ARM Assembly Language, ARM Cortex Architecture and its components, and Hardware Experiments using TILM3S1968. Written for those interested in learning embedded programming using an ARM Microcontroller. ·         Introduces number systems and signal transmission methods   ·         Reviews logic gates, registers, multiplexers, decoders and memory   ·         Provides an overview and examples of ARM instruction set   ·         Uses using Keil development tools for writing and debugging ARM assembly language Programs   ·         Hardware experiments using a Mbed NXP LPC1768 microcontroller; including General Purpose Input/Output (GPIO) configuration, real time clock configuration, binary input to 7-segment display, creating ...

  10. PHENIX Muon Arms

    International Nuclear Information System (INIS)

    Akikawa, H.; Al-Jamel, A.; Archuleta, J.B.; Archuleta, J.R.; Armendariz, R.; Armijo, V.; Awes, T.C.; Baldisseri, A.; Barker, A.B.; Barnes, P.D.; Bassalleck, B.; Batsouli, S.; Behrendt, J.; Bellaiche, F.G.; Bland, A.W.; Bobrek, M.; Boissevain, J.G.; Borel, H.; Brooks, M.L.; Brown, A.W.; Brown, D.S.; Bruner, N.; Cafferty, M.M.; Carey, T.A.; Chai, J.-S.; Chavez, L.L.; Chollet, S.; Choudhury, R.K.; Chung, M.S.; Cianciolo, V.; Clark, D.J.; Cobigo, Y.; Dabrowski, C.M.; Debraine, A.; DeMoss, J.; Dinesh, B.V.; Drachenberg, J.L.; Drapier, O.; Echave, M.A.; Efremenko, Y.V.; En'yo, H.; Fields, D.E.; Fleuret, F.; Fried, J.; Fujisawa, E.; Funahashi, H.; Gadrat, S.; Gastaldi, F.; Gee, T.F.; Glenn, A.; Gogiberidze, G.; Gonin, M.; Gosset, J.; Goto, Y.; Granier de Cassagnac, R.; Hance, R.H.; Hart, G.W.; Hayashi, N.; Held, S.; Hicks, J.S.; Hill, J.C.; Hoade, R.; Hong, B.; Hoover, A.; Horaguchi, T.; Hunter, C.T.; Hurst, D.E.; Ichihara, T.; Imai, K.; Isenhower, L.D.L. Davis; Isenhower, L.D.L. Donald; Ishihara, M.; Jang, W.Y.; Johnson, J.; Jouan, D.; Kamihara, N.; Kamyshkov, Y.; Kang, J.H.; Kapoor, S.S.; Kim, D.J.; Kim, D.-W.; Kim, G.-B.; Kinnison, W.W.; Klinksiek, S.; Kluberg, L.; Kobayashi, H.; Koehler, D.; Kotchenda, L.; Kuberg, C.H.; Kurita, K.; Kweon, M.J.; Kwon, Y.; Kyle, G.S.; LaBounty, J.J.; Lajoie, J.G.; Lee, D.M.; Lee, S.; Leitch, M.J.; Li, Z.; Liu, M.X.; Liu, X.; Liu, Y.; Lockner, E.; Lopez, J.D.; Mao, Y.; Martinez, X.B.; McCain, M.C.; McGaughey, P.L.; Mioduszewski, S.; Mischke, R.E.; Mohanty, A.K.; Montoya, B.C.; Moss, J.M.; Murata, J.; Murray, M.M.; Nagle, J.L.; Nakada, Y.; Newby, J.; Obenshain, F.; Palounek, A.P.T.; Papavassiliou, V.; Pate, S.F.; Plasil, F.; Pope, K.; Qualls, J.M.; Rao, G.; Read, K.F.; Robinson, S.H.; Roche, G.; Romana, A.; Rosnet, P.; Roth, R.; Saito, N.; Sakuma, T.; Sandhoff, W.F.; Sanfratello, L.; Sato, H.D.; Savino, R.; Sekimoto, M.; Shaw, M.R.; Shibata, T.-A.; Sim, K.S.; Skank, H.D.; Smith, D.E.; Smith, G.D.; Sondheim, W.E.; Sorensen, S.; Staley, F.; Stankus, P.W.; Steffens, S.; Stein, E.M.; Stepanov, M.; Stokes, W.; Sugioka, M.; Sun, Z.; Taketani, A.; Taniguchi, E.; Tepe, J.D.; Thornton, G.W.; Tian, W.; Tojo, J.; Torii, H.; Towell, R.S.; Tradeski, J.; Vassent, M.; Velissaris, C.; Villatte, L.; Wan, Y.; Watanabe, Y.; Watkins, L.C.; Whitus, B.R.; Williams, C.; Willis, P.S.; Wong-Swanson, B.G.; Yang, Y.; Yoneyama, S.; Young, G.R.; Zhou, S.

    2003-01-01

    The PHENIX Muon Arms detect muons at rapidities of |y|=(1.2-2.4) with full azimuthal acceptance. Each muon arm must track and identify muons and provide good rejection of pions and kaons (∼10 -3 ). In order to accomplish this we employ a radial field magnetic spectrometer with precision tracking (Muon Tracker) followed by a stack of absorber/low resolution tracking layers (Muon Identifier). The design, construction, testing and expected run parameters of both the muon tracker and the muon identifier are described

  11. PHENIX Muon Arms

    Energy Technology Data Exchange (ETDEWEB)

    Akikawa, H.; Al-Jamel, A.; Archuleta, J.B.; Archuleta, J.R.; Armendariz, R.; Armijo, V.; Awes, T.C.; Baldisseri, A.; Barker, A.B.; Barnes, P.D.; Bassalleck, B.; Batsouli, S.; Behrendt, J.; Bellaiche, F.G.; Bland, A.W.; Bobrek, M.; Boissevain, J.G.; Borel, H.; Brooks, M.L.; Brown, A.W.; Brown, D.S.; Bruner, N.; Cafferty, M.M.; Carey, T.A.; Chai, J.-S.; Chavez, L.L.; Chollet, S.; Choudhury, R.K.; Chung, M.S.; Cianciolo, V.; Clark, D.J.; Cobigo, Y.; Dabrowski, C.M.; Debraine, A.; DeMoss, J.; Dinesh, B.V.; Drachenberg, J.L.; Drapier, O.; Echave, M.A.; Efremenko, Y.V.; En' yo, H.; Fields, D.E.; Fleuret, F.; Fried, J.; Fujisawa, E.; Funahashi, H.; Gadrat, S.; Gastaldi, F.; Gee, T.F.; Glenn, A.; Gogiberidze, G.; Gonin, M.; Gosset, J.; Goto, Y.; Granier de Cassagnac, R.; Hance, R.H.; Hart, G.W.; Hayashi, N.; Held, S.; Hicks, J.S.; Hill, J.C.; Hoade, R.; Hong, B.; Hoover, A.; Horaguchi, T.; Hunter, C.T.; Hurst, D.E.; Ichihara, T.; Imai, K.; Isenhower, L.D.L. Davis; Isenhower, L.D.L. Donald; Ishihara, M.; Jang, W.Y.; Johnson, J.; Jouan, D.; Kamihara, N.; Kamyshkov, Y.; Kang, J.H.; Kapoor, S.S.; Kim, D.J.; Kim, D.-W.; Kim, G.-B.; Kinnison, W.W.; Klinksiek, S.; Kluberg, L.; Kobayashi, H.; Koehler, D.; Kotchenda, L.; Kuberg, C.H.; Kurita, K.; Kweon, M.J.; Kwon, Y.; Kyle, G.S.; LaBounty, J.J.; Lajoie, J.G.; Lee, D.M.; Lee, S.; Leitch, M.J.; Li, Z.; Liu, M.X.; Liu, X.; Liu, Y.; Lockner, E.; Lopez, J.D.; Mao, Y.; Martinez, X.B.; McCain, M.C.; McGaughey, P.L.; Mioduszewski, S.; Mischke, R.E.; Mohanty, A.K.; Montoya, B.C.; Moss, J.M.; Murata, J.; Murray, M.M.; Nagle, J.L.; Nakada, Y.; Newby, J.; Obenshain, F.; Palounek, A.P.T.; Papavassiliou, V.; Pate, S.F.; Plasil, F.; Pope, K.; Qualls, J.M.; Rao, G.; Read, K.F. E-mail: readkf@ornl.gov; Robinson, S.H.; Roche, G.; Romana, A.; Rosnet, P.; Roth, R.; Saito, N.; Sakuma, T.; Sandhoff, W.F.; Sanfratello, L.; Sato, H.D.; Savino, R.; Sekimoto, M.; Shaw, M.R.; Shibata, T.-A.; Sim, K.S.; Skank, H.D.; Smith, D.E.; Smith, G.D. [and others

    2003-03-01

    The PHENIX Muon Arms detect muons at rapidities of |y|=(1.2-2.4) with full azimuthal acceptance. Each muon arm must track and identify muons and provide good rejection of pions and kaons ({approx}10{sup -3}). In order to accomplish this we employ a radial field magnetic spectrometer with precision tracking (Muon Tracker) followed by a stack of absorber/low resolution tracking layers (Muon Identifier). The design, construction, testing and expected run parameters of both the muon tracker and the muon identifier are described.

  12. Kootenay Lake Fertilization Experiment, Year 15 (North Arm) and Year 3 (South Arm) (2006) Report

    Energy Technology Data Exchange (ETDEWEB)

    Schindler, E.U.; Sebastian, D.; Andrusak, G.F. [Fish and Wildlife Science and Allocation, Ministry of Environment, Province of British Columbia

    2009-07-01

    This report summarizes results from the fifteenth year (2006) of nutrient additions to the North Arm of Kootenay Lake and three years of nutrient additions to the South Arm. Experimental fertilization of the lake has been conducted using an adaptive management approach in an effort to restore lake productivity lost as a result of nutrient uptake in upstream reservoirs. The primary objective of the experiment is to restore kokanee (Oncorhynchus nerka) populations, which are the main food source for Gerrard rainbow trout (Oncorhynchus mykiss) and bull trout (Salvelinus confluentus). The quantity of agricultural grade liquid fertilizer (10-34-0, ammonium polyphosphate and 28-0-0, urea ammonium nitrate) added to the North Arm in 2006 was 44.7 tonnes of P and 248.4 tonnes of N. The total fertilizer load added to the South Arm was 257 tonnes of nitrogen; no P was added. Kootenay Lake has an area of 395 km{sup 2}, a maximum depth of 150 m, a mean depth of 94 m, and a water renewal time of approximately two years. Kootenay Lake is a monomictic lake, generally mixing from late fall to early spring and stratifying during the summer. Surface water temperatures generally exceed 20 C for only a few weeks in July. Results of oxygen profiles were similar to previous years with the lake being well oxygenated from the surface to the bottom depths at all stations. Similar to past years, Secchi disc measurements at all stations in 2006 indicate a typical seasonal pattern of decreasing depths associated with the spring phytoplankton bloom, followed by increasing depths as the bloom gradually decreases by the late summer and fall. Total phosphorus (TP) ranged from 2-7 {micro}g/L and tended to decrease as summer advanced. Over the sampling season dissolved inorganic nitrogen (DIN) concentrations decreased, with the decline corresponding to nitrate (the dominant component of DIN) being utilized by phytoplankton during summer stratification. Owing to the importance of epilimnetic nitrate

  13. Association between intramuscular fat in the arm following arm training and INSIG2

    DEFF Research Database (Denmark)

    Popadic Gacesa, J Z; Secher, N H; Momcilovic, M

    2014-01-01

    ) ; mean ± standard deviation) carried out a 12-week two-arm elbow extensor training (10 maximal extensions with 1 min recovery between bouts) five times per day, five times per week. For 17 volunteers, upper arm muscle and adipose tissue [subcutaneous (SCAT) and intramuscular (IMAT)] volumes were.......0 ± 0.9%; GC/CC: %IMAT 0.6 ± 0.5% (P > 0.05). However, in the year following the training, accumulation of upper arm IMAT was twice as large in participants homozygous for the G allele (GG: Δ%IMAT +2.5 ± 0.8%; GC/CC: Δ%IMAT +1.1 ± 0.7%; P 

  14. Design of a biomimetic robotic octopus arm.

    Science.gov (United States)

    Laschi, C; Mazzolai, B; Mattoli, V; Cianchetti, M; Dario, P

    2009-03-01

    This paper reports the rationale and design of a robotic arm, as inspired by an octopus arm. The octopus arm shows peculiar features, such as the ability to bend in all directions, to produce fast elongations, and to vary its stiffness. The octopus achieves these unique motor skills, thanks to its peculiar muscular structure, named muscular hydrostat. Different muscles arranged on orthogonal planes generate an antagonistic action on each other in the muscular hydrostat, which does not change its volume during muscle contractions, and allow bending and elongation of the arm and stiffness variation. By drawing inspiration from natural skills of octopus, and by analysing the geometry and mechanics of the muscular structure of its arm, we propose the design of a robot arm consisting of an artificial muscular hydrostat structure, which is completely soft and compliant, but also able to stiffen. In this paper, we discuss the design criteria of the robotic arm and how this design and the special arrangement of its muscular structure may bring the building of a robotic arm into being, by showing the results obtained by mathematical models and prototypical mock-ups.

  15. Design of a biomimetic robotic octopus arm

    Energy Technology Data Exchange (ETDEWEB)

    Laschi, C; Cianchetti, M [Advanced Robotics Technology and Systems Laboratory, Scuola Superiore Sant' Anna, Pisa (Italy); Mazzolai, B; Dario, P [Italian Institute of Technology, Genova (Italy); Mattoli, V [Centre of Research in Microengineering Laboratory, Scuola Superiore Sant' Anna, Pisa (Italy)], E-mail: cecilia.laschi@sssup.it

    2009-03-01

    This paper reports the rationale and design of a robotic arm, as inspired by an octopus arm. The octopus arm shows peculiar features, such as the ability to bend in all directions, to produce fast elongations, and to vary its stiffness. The octopus achieves these unique motor skills, thanks to its peculiar muscular structure, named muscular hydrostat. Different muscles arranged on orthogonal planes generate an antagonistic action on each other in the muscular hydrostat, which does not change its volume during muscle contractions, and allow bending and elongation of the arm and stiffness variation. By drawing inspiration from natural skills of octopus, and by analysing the geometry and mechanics of the muscular structure of its arm, we propose the design of a robot arm consisting of an artificial muscular hydrostat structure, which is completely soft and compliant, but also able to stiffen. In this paper, we discuss the design criteria of the robotic arm and how this design and the special arrangement of its muscular structure may bring the building of a robotic arm into being, by showing the results obtained by mathematical models and prototypical mock-ups.

  16. Design of a biomimetic robotic octopus arm

    International Nuclear Information System (INIS)

    Laschi, C; Cianchetti, M; Mazzolai, B; Dario, P; Mattoli, V

    2009-01-01

    This paper reports the rationale and design of a robotic arm, as inspired by an octopus arm. The octopus arm shows peculiar features, such as the ability to bend in all directions, to produce fast elongations, and to vary its stiffness. The octopus achieves these unique motor skills, thanks to its peculiar muscular structure, named muscular hydrostat. Different muscles arranged on orthogonal planes generate an antagonistic action on each other in the muscular hydrostat, which does not change its volume during muscle contractions, and allow bending and elongation of the arm and stiffness variation. By drawing inspiration from natural skills of octopus, and by analysing the geometry and mechanics of the muscular structure of its arm, we propose the design of a robot arm consisting of an artificial muscular hydrostat structure, which is completely soft and compliant, but also able to stiffen. In this paper, we discuss the design criteria of the robotic arm and how this design and the special arrangement of its muscular structure may bring the building of a robotic arm into being, by showing the results obtained by mathematical models and prototypical mock-ups

  17. Weighted Traffic Equilibrium Problem in Non Pivot Hilbert Spaces with Long Term Memory

    International Nuclear Information System (INIS)

    Giuffre, Sofia; Pia, Stephane

    2010-01-01

    In the paper we consider a weighted traffic equilibrium problem in a non-pivot Hilbert space and prove the equivalence between a weighted Wardrop condition and a variational inequality with long term memory. As an application we show, using recent results of the Senseable Laboratory at MIT, how wireless devices can be used to optimize the traffic equilibrium problem.

  18. Arm-in-Arm Response Regulator Dimers Promote Intermolecular Signal Transduction

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Anna W.; Satyshur, Kenneth A.; Morales, Neydis Moreno; Forest, Katrina T. (UW)

    2016-02-01

    ABSTRACT

    Bacteriophytochrome photoreceptors (BphPs) and their cognate response regulators make up two-component signal transduction systems which direct bacteria to mount phenotypic responses to changes in environmental light quality. Most of these systems utilize single-domain response regulators to transduce signals through unknown pathways and mechanisms. Here we describe the photocycle and autophosphorylation kinetics of RtBphP1, a red light-regulated histidine kinase from the desert bacteriumRamlibacter tataouinensis. RtBphP1 undergoes red to far-red photoconversion with rapid thermal reversion to the dark state. RtBphP1 is autophosphorylated in the dark; this activity is inhibited under red light. The RtBphP1 cognate response regulator, theR. tataouinensisbacteriophytochrome response regulator (RtBRR), and a homolog, AtBRR fromAgrobacterium tumefaciens, crystallize unexpectedly as arm-in-arm dimers, reliant on a conserved hydrophobic motif, hFWAhL (where h is a hydrophobic M, V, L, or I residue). RtBRR and AtBRR dimerize distinctly from four structurally characterized phytochrome response regulators found in photosynthetic organisms and from all other receiver domain homodimers in the Protein Data Bank. A unique cacodylate-zinc-histidine tag metal organic framework yielded single-wavelength anomalous diffraction phases and may be of general interest. Examination of the effect of the BRR stoichiometry on signal transduction showed that phosphorylated RtBRR is accumulated more efficiently than the engineered monomeric RtBRR (RtBRRmon) in phosphotransfer reactions. Thus, we conclude that arm-in-arm dimers are a relevant signaling intermediate in this class of two-component regulatory systems.

  19. How does a planet excite multiple spiral arms?

    Science.gov (United States)

    Bae, Jaehan; Zhu, Zhaohuan

    2018-01-01

    Protoplanetary disk simulations show that a single planet excites multiple spiral arms in the background disk, potentially supported by the multi-armed spirals revealed with recent high-resolution observations in some disks. The existence of multiple spiral arms is of importance in many aspects. It is empirically found that the arm-to-arm separation increases as a function of the planetary mass, so one can use the morphology of observed spiral arms to infer the mass of unseen planets. In addition, a spiral arm opens a radial gap as it steepens into a shock, so when a planet excites multiple spiral arms it can open multiple gaps in the disk. Despite the important implications, however, the formation mechanism of multiple spiral arms has not been fully understood by far.In this talk, we explain how a planet excites multiple spiral arms. The gravitational potential of a planet can be decomposed into a Fourier series, a sum of individual azimuthal modes having different azimuthal wavenumbers. Using a linear wave theory, we first demonstrate that appropriate sets of Fourier decomposed waves can be in phase, raising a possibility that constructive interference among the waves can produce coherent structures - spiral arms. More than one spiral arm can form since such constructive interference can occur at different positions in the disk for different sets of waves. We then verify this hypothesis using a suite of two-dimensional hydrodynamic simulations. Finally, we present non-linear behavior in the formation of multiple spiral arms.

  20. Managing new arms races

    International Nuclear Information System (INIS)

    Segal, G.

    1992-01-01

    The management of new arms races in the region of Asia-Pacific includes considerations of weapons trade and transfer in the region, with an emphasis on nuclear weapons proliferation. It deals with the problem of controlling the arms trade and the efforts to control conventional weapons and underlines the possible role and influence of Conference on Cooperation and Security in Europe (CSCE)

  1. Pivotal temperature and sexual dimorphism of Podocnemis expansa hatchlings (Testudines: Podocnemididae from Bananal Island, Brazil

    Directory of Open Access Journals (Sweden)

    Adélio Lubiana

    2009-09-01

    Full Text Available A common problem when trying to identify the sex of hatchling turtles is that juveniles are not obviously externally dimorphic and current techniques to identify sex are often invasive. In this paper, 300 eggs of Podocnemis expansa from Bananal Island, state of Tocantins (Brazil, were incubated at constant temperatures. The carapaces of the hatchlings were photographed and subjected to geometric morphometric analysis. The hatchlings were subsequently euthanized and had their gonads removed for sex determination. The pivotal temperature of P. expansa was 33.5ºC, confirming that this species has the highest pivotal temperature among reptiles. Geometric morphometric analysis of the shape of the carapace proved efficient in differentiating the sex of the hatchlings and confirmed that this methodology can be efficient for studies that need to ascertain the sex ratio in P. expansa hatchlings.

  2. A Comparison of Image Quality and Radiation Exposure Between the Mini C-Arm and the Standard C-Arm.

    Science.gov (United States)

    van Rappard, Juliaan R M; Hummel, Willy A; de Jong, Tijmen; Mouës, Chantal M

    2018-04-01

    The use of intraoperative fluoroscopy has become mandatory in osseous hand surgery. Due to its overall practicality, the mini C-arm has gained popularity among hand surgeons over the standard C-arm. This study compares image quality and radiation exposure for patient and staff between the mini C-arm and the standard C-arm, both with flat panel technology. An observer-based subjective image quality study was performed using a contrast detail (CD) phantom. Five independent observers were asked to determine the smallest circles discernable to them. The results were plotted in a graph, forming a CD curve. From each curve, an image quality figure (IQF) was derived. A lower IQF equates to a better image quality. The patients' entrance skin dose was measured, and to obtain more information about the staff exposure dose, a perspex hand phantom was used. The scatter radiation was measured at various distances and angles relative to a central point on the detector. The IQF was significantly lower for the mini C-arm resulting in a better image quality. The patients' entrance dose was 10 times higher for the mini C-arm as compared with the standard C-arm, and the scatter radiation threefold. Due to its improved image quality and overall practicality, the mini C-arm is recommended for hand surgical procedures. To ensure that the surgeons' radiation exposure is not exceeding the safety limits, monitoring radiation exposure using mini C-arms with flat panel technology during surgery should be done in a future clinical study.

  3. Changes in arm-hand function and arm-hand skill performance in patients after stroke during and after rehabilitation.

    Science.gov (United States)

    Franck, Johan Anton; Smeets, Rob Johannes Elise Marie; Seelen, Henk Alexander Maria

    2017-01-01

    Arm-hand rehabilitation programs applied in stroke rehabilitation frequently target specific populations and thus are less applicable in heterogeneous patient populations. Besides, changes in arm-hand function (AHF) and arm-hand skill performance (AHSP) during and after a specific and well-described rehabilitation treatment are often not well evaluated. This single-armed prospective cohort study featured three subgroups of stroke patients with either a severely, moderately or mildly impaired AHF. Rehabilitation treatment consisted of a Concise_Arm_and_hand_ Rehabilitation_Approach_in_Stroke (CARAS). Measurements at function and activity level were performed at admission, clinical discharge, 3, 6, 9 and 12 months after clinical discharge. Eighty-nine stroke patients (M/F:63/23; mean age:57.6yr (+/-10.6); post-stroke time:29.8 days (+/-20.1)) participated. All patients improved on AHF and arm-hand capacity during and after rehabilitation, except on grip strength in the severely affected subgroup. Largest gains occurred in patients with a moderately affected AHF. As to self-perceived AHSP, on average, all subgroups improved over time. A small percentage of patients declined regarding self-perceived AHSP post-rehabilitation. A majority of stroke patients across the whole arm-hand impairment severity spectrum significantly improved on AHF, arm-hand capacity and self-perceived AHSP. These were maintained up to one year post-rehabilitation. Results may serve as a control condition in future studies.

  4. Neural Mechanisms of Improvements in Social Motivation after Pivotal Response Treatment: Two Case Studies

    Science.gov (United States)

    Voos, Avery C.; Pelphrey, Kevin A.; Tirrell, Jonathan; Bolling, Danielle Z.; Vander Wyk, Brent; Kaiser, Martha D.; McPartland, James C.; Volkmar, Fred R.; Ventola, Pamela

    2013-01-01

    Pivotal response treatment (PRT) is an empirically validated behavioral treatment that has widespread positive effects on communication, behavior, and social skills in young children with autism spectrum disorder (ASD). For the first time, functional magnetic resonance imaging was used to identify the neural correlates of successful response to…

  5. CHARACTERISTICS OF SPIRAL ARMS IN LATE-TYPE GALAXIES

    International Nuclear Information System (INIS)

    Honig, Z. N.; Reid, M. J.

    2015-01-01

    We have measured the positions of large numbers of H II regions in four nearly face-on, late-type, spiral galaxies: NGC 628 (M74), NGC 1232, NGC 3184, and NGC 5194 (M51). Fitting log-periodic spiral models to segments of each arm yields local estimates of spiral pitch angle and arm width. While pitch angles vary considerably along individual arms, among arms within a galaxy, and among galaxies, we find no systematic trend with galactocentric distance. We estimate the widths of the arm segments from the scatter in the distances of the H II regions from the spiral model. All major arms in these galaxies show spiral arm width increasing with distance from the galactic center, similar to the trend seen in the Milky Way. However, in the outermost parts of the galaxies, where massive star formation declines, some arms reverse this trend and narrow. We find that spiral arms often appear to be composed of segments of ∼5 kpc length, which join to form kinks and abrupt changes in pitch angle and arm width; these characteristics are consistent with properties seen in the large N-body simulations of D'Onghia et al. and others

  6. Training the Unimpaired Arm Improves the Motion of the Impaired Arm and the Sitting Balance in Chronic Stroke Survivors.

    Science.gov (United States)

    De Luca, Alice; Giannoni, Psiche; Vernetti, Honore; Capra, Cristina; Lentino, Carmelo; Checchia, Giovanni Antonio; Casadio, Maura

    2017-07-01

    Robot-assisted rehabilitation of stroke survivors mainly focuses on the impaired side of the body while the role of the unimpaired side in the recovery after stroke is still controversial. The goal of this study is to investigate the influence on sitting balance and paretic arm functions of a training protocol based on movements of the unimpaired arm. Sixteen chronic stroke survivors underwent nineteen training sessions, in which they performed active movements with the unimpaired arm supported by a passive exoskeleton. Performance of the trunk and upper limbs was evaluated before treatment, after treatment and at six months follow up with clinical scales and an instrumented evaluation. A reaching test executed with the exoskeleton was used to assess changes in performance of both arms. The treatment based on the unimpaired arm's movements executed with a correct body posture led to benefits in control of the trunk and of both the trained and the untrained arm. The amount of impaired arm improvement in the Fugl-Meyer score was comparable to the outcome of robotic treatments focused directly on this arm. Our results highlight the importance of taking into account all body schema in the rehabilitation robotic program, instead of focusing only on the impaired side of the body.

  7. Picking Robot Arm Trajectory Planning Method

    Directory of Open Access Journals (Sweden)

    Zhang Zhiyong

    2014-01-01

    Full Text Available The picking robot arm is scheduled to complete picking tasks in the working space, to overcome the shaking vibration to improve the picking stability, its movement should follow specific consistence trajectory points. Usually we should give definite multiple feature picking points, map their inverse kinematics to the joint space, establish motion equation for the corresponding point in the joint space, then follow these equations motion for the interpolation on the joint so that we can meet the movement requirements. Trajectory planning is decisive significance for accuracy and stability of controlling robot arm. The key issue that picking arm complete picking task will be come true by trajectory planning, namely, robot arm track the desired trajectory. which based on kinematics and statics picking analysis in a joint space according to the requirements of picking tasks, and obtain the position and orientation for picking robot arm, study and calculate the theory of trajectory parameters timely.

  8. Arm locking with Doppler estimation errors

    Energy Technology Data Exchange (ETDEWEB)

    Yu Yinan; Wand, Vinzenz; Mitryk, Shawn; Mueller, Guido, E-mail: yinan@phys.ufl.ed [Department of Physics, University of Florida, Gainesville, FL 32611 (United States)

    2010-05-01

    At the University of Florida we developed the University of Florida LISA Interferometer Simulator (UFLIS) in order to study LISA interferometry with hardware in the loop at a system level. One of the proposed laser frequency stabilization techniques in LISA is arm locking. Arm locking uses an adequately filtered linear combination of the LISA arm signals as a frequency reference. We will report about experiments in which we demonstrated arm locking using UFLIS. During these experiments we also discovered a problem associated with the Doppler shift of the return beam. The initial arm locking publications assumed that this Doppler shift can perfectly be subtracted inside the phasemeter or adds an insignificant offset to the sensor signal. However, the remaining Doppler knowledge error will cause a constant change in the laser frequency if unaccounted for. Several ways to circumvent this problem have been identified. We performed detailed simulations and started preliminary experiments to verify the performance of the proposed new controller designs.

  9. Supporting the President's Arms Control and Nonproliferation Agenda: Transparency and Verification for Nuclear Arms Reductions

    International Nuclear Information System (INIS)

    Doyle, James E.; Meek, Elizabeth

    2009-01-01

    The President's arms control and nonproliferation agenda is still evolving and the details of initiatives supporting it remain undefined. This means that DOE, NNSA, NA-20, NA-24 and the national laboratories can help define the agenda, and the policies and the initiatives to support it. This will require effective internal and interagency coordination. The arms control and nonproliferation agenda is broad and includes the path-breaking goal of creating conditions for the elimination of nuclear weapons. Responsibility for various elements of the agenda will be widely scattered across the interagency. Therefore an interagency mapping exercise should be performed to identify the key points of engagement within NNSA and other agencies for creating effective policy coordination mechanisms. These can include informal networks, working groups, coordinating committees, interagency task forces, etc. It will be important for NA-20 and NA-24 to get a seat at the table and a functional role in many of these coordinating bodies. The arms control and nonproliferation agenda comprises both mature and developing policy initiatives. The more mature elements such as CTBT ratification and a follow-on strategic nuclear arms treaty with Russia have defined milestones. However, recent press reports indicate that even the START follow-on strategic arms pact that is planned to be complete by the end of 2009 may take significantly longer and be more expansive in scope. The Russians called for proposals to count non-deployed as well as deployed warheads. Other elements of the agenda such as FMCT, future bilateral nuclear arms reductions following a START follow-on treaty, nuclear posture changes, preparations for an international nuclear security summit, strengthened international safeguards and multilateral verification are in much earlier stages of development. For this reason any survey of arms control capabilities within the USG should be structured to address potential needs across the

  10. Simulation of Octopus Arm Based on Coupled CPGs

    Directory of Open Access Journals (Sweden)

    Juan Tian

    2015-01-01

    Full Text Available The octopus arm has attracted many researchers’ interests and became a research hot spot because of its amazing features. Several dynamic models inspired by an octopus arm are presented to realize the structure with a large number of degrees of freedom. The octopus arm is made of a soft material introducing high-dimensionality, nonlinearity, and elasticity, which makes the octopus arm difficult to control. In this paper, three coupled central pattern generators (CPGs are built and a 2-dimensional dynamic model of the octopus arm is presented to explore possible strategies of the octopus movement control. And the CPGs’ signals treated as activation are added on the ventral, dorsal, and transversal sides, respectively. The effects of the octopus arm are discussed when the parameters of the CPGs are changed. Simulations show that the octopus arm movements are mainly determined by the shapes of three CPGs’ phase diagrams. Therefore, some locomotion modes are supposed to be embedded in the neuromuscular system of the octopus arm. And the octopus arm movements can be achieved by modulating the parameters of the CPGs. The results are beneficial for researchers to understand the octopus movement further.

  11. Arm-to-arm variation when evaluating neuromuscular block: an analysis of the precision and the bias and agreement between arms when using mechanomyography or acceleromyography

    DEFF Research Database (Denmark)

    Claudius, C; Skovgaard, L T; Viby-Mogensen, J

    2010-01-01

    Studies comparing acceleromyography and mechanomyography indicate that the two methods cannot be used interchangeably. However, it is uncertain to what extent differences in precision between the methods and the naturally occurring arm-to-arm variation have influenced the results of these studies...

  12. Pivotal Response Treatment for Infants At-Risk for Autism Spectrum Disorders: A Pilot Study

    Science.gov (United States)

    Steiner, Amanda Mossman; Gengoux, Grace W.; Klin, Ami; Chawarska, Katarzyna

    2013-01-01

    Presently there is limited research to suggest efficacious interventions for infants at-risk for autism. Pivotal response treatment (PRT) has empirical support for use with preschool children with autism, but there are no reports in the literature utilizing this approach with infants. In the current study, a developmental adaptation of PRT was…

  13. Thermal–Hydrodynamic Behaviour of Coated Pivoted Pad Thrust Bearings: Comparison between Babbitt, PTFE and DLC

    Directory of Open Access Journals (Sweden)

    Konstantinos Katsaros

    2018-05-01

    Full Text Available The hydrodynamic lubrication and thermal analysis of tilting pad thrust bearings has been a major subject for many studies in the field of tribology. There is only a limited number of studies regarding thrust bearings with coated surfaces. The purpose of this study is to build a parametric, iterative algorithm in order to perform a complete thermal and hydrodynamic lubrication analysis for pivoted pad thrust bearings with coatings. The analytical model is mainly based on the energy, continuity and Navier–Stokes equations, which are solved numerically with the Semi-Implicit Method for Pressure Linked Equations Consistent (SIMPLEC method. The analysis focuses on a single pivoted pad of the thrust bearing. The thermal properties of the coating material are taken into account and the resulting thermal and flow fields are solved. The basic hydrodynamic and tribological characteristics are calculated for an uncoated, a Babbitt coated, a PTFE coated and a diamond like carbon (DLC coated pivoted pad thrust bearing. The pressure and the film thickness distribution, as well as the load capacity and the frictional forces, are determined for several pad positions and velocities of the rotor. A mineral oil lubricant is used to estimate the shear thinning or thickening effects on the pad tribological performance. The results indicate that pads coated with PTFE and DLC show lower friction forces compared to the common steel and Babbitt applications. At the same time, the DLC coating seems to affect the bearing’s flow and thermal fields less than the PTFE, making it more suitable for thrust bearings applications.

  14. Effects of an Off-Axis Pivoting Elliptical Training Program on Gait Function in Persons With Spastic Cerebral Palsy: A Preliminary Study.

    Science.gov (United States)

    Tsai, Liang-Ching; Ren, Yupeng; Gaebler-Spira, Deborah J; Revivo, Gadi A; Zhang, Li-Qun

    2017-07-01

    This preliminary study examined the effects of off-axis elliptical training on reducing transverse-plane gait deviations and improving gait function in 8 individuals with cerebral palsy (CP) (15.5 ± 4.1 years) who completed an training program using a custom-made elliptical trainer that allows transverse-plane pivoting of the footplates during exercise. Lower-extremity off-axis control during elliptical exercise was evaluated by quantifying the root-mean-square and maximal angular displacement of the footplate pivoting angle. Lower-extremity pivoting strength was assessed. Gait function and balance were evaluated using 10-m walk test, 6-minute-walk test, and Pediatric Balance Scale. Toe-in angles during gait were quantified. Participants with CP demonstrated a significant decrease in the pivoting angle (root mean square and maximal angular displacement; effect size, 1.00-2.00) and increase in the lower-extremity pivoting strength (effect size = 0.91-1.09) after training. Reduced 10-m walk test time (11.9 ± 3.7 seconds vs. 10.8 ± 3.0 seconds; P = 0.004; effect size = 1.46), increased Pediatric Balance Scale score (43.6 ± 12.9 vs. 45.6 ± 10.8; P = 0.042; effect size = 0.79), and decreased toe-in angle (3.7 ± 10.5 degrees vs. 0.7 ± 11.7 degrees; P = 0.011; effect size = 1.22) were observed after training. We present an intervention to challenge lower-extremity off-axis control during a weight-bearing and functional activity for individuals with CP. Our preliminary findings suggest that this intervention was effective in enhancing off-axis control, gait function, and balance and reducing in-toeing gait in persons with CP.

  15. Broken Arm

    Science.gov (United States)

    ... of falling — including football, soccer, gymnastics, skiing and skateboarding — also increases the risk of a broken arm. ... for high-risk activities, such as in-line skating, snowboarding, rugby and football. Don't smoke. Smoking ...

  16. 49 CFR 236.810 - Spectacle, semaphore arm.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Spectacle, semaphore arm. 236.810 Section 236.810 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Spectacle, semaphore arm. That part of a semaphore arm which holds the roundels and to which the blade is...

  17. Arming shoes of the fifteenth century

    OpenAIRE

    Volken Marquita

    2017-01-01

    Military footwear for the fifteenth century includes arming shoes worn under sabatons. Written sources suggest arming shoes and footwear used for fighting were ordinary shoes adapted for the purpose. Archaeological footwear was examined for signs of such modifications. Medieval shoe technology is presented, showing the range of footwear and its uses and gait biomechanics. Based on experiences from re-enactors wearing armours, medieval shoe styles are discussed for appropriateness as arming sh...

  18. Clusters and pivots for evaluating a large numberof alternatives in AHP

    Directory of Open Access Journals (Sweden)

    Alessio Ishizaka

    2012-04-01

    Full Text Available AHP has been successful in many cases but it has a major limitation: a larger number of alternatives requires a high number of judgements in the comparison matrices. In order to reduce this problem,we present a method with clusters and pivots. This method also helps with a further four problems of the Analytic Hierarchy Process. It enlarges the comparison scale, facilitates the construction of a consistent or near consistent matrix, eliminates the problem of the choice of the priorities derivation method and allows the use of incomparable alternatives.

  19. International security and arms control

    International Nuclear Information System (INIS)

    Ekeus, R.

    2000-01-01

    The end of the cold war also ended the focus on the bilateral approach to arms control and disarmament. Key concepts of security needed to be revisited, along with their implications for the disarmament and arms control agenda. Though there is currently a unipolar global security environment, there remain important tasks on the multilateral arms control agenda. The major task is that of reducing and eliminating weapons of mass destruction, especially nuclear weapons. The author contends that maintaining reliance on the nuclear-weapons option makes little sense in a time when the major Powers are strengthening their partnerships in economics, trade, peacemaking and building. (author)

  20. Preventing Interstate Armed Conflict : whose responsibility?

    OpenAIRE

    Otunba, Ganiyu

    2010-01-01

    This is a study of interstate armed conflict prevention. The concept of conflict, armed conflict and conflict prevention is defined and explained in order to be able to investigate if there is any single institution saddled with the responsibility of preventing interstate armed conflict and also to verify if adequate efforts are been put in this area which is of importance to mankind. The relationship between conflict prevention, conflict management and conflict resolution is also discussed s...

  1. Strategic arms limitation

    Science.gov (United States)

    Allen Greb, G.; Johnson, Gerald W.

    1983-10-01

    Following World War II, American scientists and politicians proposed in the Baruch plan a radical solution to the problem of nuclear weapons: to eliminate them forever under the auspices of an international nuclear development authority. The Soviets, who as yet did not possess the bomb, rejected this plan. Another approach suggested by Secretary of War Henry Stimson to negotiate directly with the Soviet Union was not accepted by the American leadership. These initial arms limitation failures both reflected and exacerbated the hostile political relationship of the superpowers in the 1950s and 1960s. Since 1969, the more modest focus of the Soviet-American arms control process has been on limiting the numbers and sizes of both defensive and offensive strategic systems. The format for this effort has been the Strategic Arms Limitatins Talks (Salt) and more recently the Strategic Arms Reduction Talks (START). Both sides came to these negotiations convinced that nuclear arsenals had grown so large that some for of mutual restraint was needed. Although the SALT/START process has been slow and ponderous, it has produced several concrete the agreements and collateral benefits. The 1972 ABM Treaty restricts the deployment of ballistic missile defense systems, the 1972 Interim Agreement places a quantitative freeze on each side's land based and sea based strategic launchers, and the as yet unratified 1979 SALT II Treaty sets numerical limits on all offensive strategic systems and sublimits on MIRVed systems. Collateral benefits include improved verification procedures, working definitions and counting rules, and permanent bureaucratic apparatus which enhance stability and increase the chances for achieving additional agreements.

  2. Planet-driven Spiral Arms in Protoplanetary Disks. II. Implications

    Science.gov (United States)

    Bae, Jaehan; Zhu, Zhaohuan

    2018-06-01

    We examine whether various characteristics of planet-driven spiral arms can be used to constrain the masses of unseen planets and their positions within their disks. By carrying out two-dimensional hydrodynamic simulations varying planet mass and disk gas temperature, we find that a larger number of spiral arms form with a smaller planet mass and a lower disk temperature. A planet excites two or more spiral arms interior to its orbit for a range of disk temperatures characterized by the disk aspect ratio 0.04≤slant {(h/r)}p≤slant 0.15, whereas exterior to a planet’s orbit multiple spiral arms can form only in cold disks with {(h/r)}p≲ 0.06. Constraining the planet mass with the pitch angle of spiral arms requires accurate disk temperature measurements that might be challenging even with ALMA. However, the property that the pitch angle of planet-driven spiral arms decreases away from the planet can be a powerful diagnostic to determine whether the planet is located interior or exterior to the observed spirals. The arm-to-arm separations increase as a function of planet mass, consistent with previous studies; however, the exact slope depends on disk temperature as well as the radial location where the arm-to-arm separations are measured. We apply these diagnostics to the spiral arms seen in MWC 758 and Elias 2–27. As shown in Bae et al., planet-driven spiral arms can create concentric rings and gaps, which can produce a more dominant observable signature than spiral arms under certain circumstances. We discuss the observability of planet-driven spiral arms versus rings and gaps.

  3. Mechanical characterization of the Varian Exact-arm and R-arm support systems for eight aS500 electronic portal imaging devices

    International Nuclear Information System (INIS)

    Grattan, Mark W. D.; McGarry, Conor K.

    2010-01-01

    Purpose: The aim of this study is to compare the positioning accuracy at different gantry angles of two electronic portal imaging devices (EPIDs) support arm systems by using EPID difference images as a measure for displacement. This work presents a comparison of the mechanical performance of eight Varian aS500 (Varian Medical Systems, Palo Alto, CA) EPIDs, mounted using either the Varian Exact-arm or R-arm. Methods: The mechanical performance of the two arm systems was compared by investigating the variation in sensitivity with gantry angle, both before and after the EPID position was adjusted after gantry rotation. Positional errors were investigated by subtracting images from a reference image taken at gantry 0 deg., and the amplitude of the peaks and troughs at the field edges for longitudinal (radial) and lateral (transverse) profiles across the resulting image was related to the distance of displacement. Calibration curves based on a pixel-by-pixel shift were generated for each EPID and the Varian hand pendant accuracy was compared to the calibration data. Results: The response of the EPIDs was found to change with gantry rotation, with the largest difference at 180 deg. The Exact-arm was found to correct well for any displacement, while the R-arm tended to overcorrect following repositioning using the hand pendant. The calibration curves were consistent within each set of matched linacs, and the hand pendant accuracy was similar for both arm systems, although generally in different directions. With respect to gantry rotation effects, the mechanical performance of the Exact-arm systems was found to be much better than that of the R-arm systems. At gantry positions 90 deg., 270 deg., and 180 deg. the average misalignment in the longitudinal direction was +4.2±0.2, +1.8±1.6, and +7.4±0.5 mm for the R-arms, and +2.9±0.2, +2.1±0.8, and +4.9±0.7 mm for the Exact-arms. In the lateral direction the average positional errors were +2.1±0.4, -4.7±0.4, and -2.5

  4. Controlling robot arm with the mind

    National Science Foundation

    2017-05-31

    Full Text Available Research test subjects at the University of Minnesota who were fitted with a specialized noninvasive brain cap were able to move a robotic arm just by imagining moving their own arms.

  5. Limited consensus around ARM information protection practices ...

    African Journals Online (AJOL)

    An existing enterprise IP SoP was adapted to ARM through literature analysis and produced a draft ARM SoP. The draft ARM SoP was applied in a rote fashion to a small sample of government-operated archives to identify likely areas of consensus and lack of consensus surrounding the various elements of the SoP.

  6. Arms Races and Negotiations

    OpenAIRE

    Sandeep Baliga; Tomas Sjostrom

    2003-01-01

    Two players simultaneously decide whether or not to acquire new weapons in an arms race game. Each player's type determines his propensity to arm. Types are private information, and are independently drawn from a continuous distribution. With probability close to one, the best outcome for each player is for neither to acquire new weapons (although each prefers to acquire new weapons if he thinks the opponent will). There is a small probability that a player is a dominant strategy type who alw...

  7. Rolling motions in an inner spiral arm

    International Nuclear Information System (INIS)

    Strauss, F.M.; Poeppel, W.

    1976-01-01

    Hydrogen line observations made at low galactic latitudes for l=318degree, 326degree, 334degree, and 337degree show the presence of velocity gradients in latitude in the nearest inner spiral arm, similar to those found by other observations in different regions. Maximum velocity change is about 10 km s -1 for l=337degree. By generating synthetic line profiles constructed from a model spiral arm, several possible causes of these ''rolling motions'' were studied, such as a vertical displacement or a tilt of the arm (which failed to account for the observations) and rotation or shearing in the arm. It was futher shown that a typical arm can maintain such a motion (approx. =75 km s -1 kpc -1 ) with its own gravitational potential. The results are used to study the origin and tilt of Gould's Belt

  8. Stainless steel decontamination manipulators

    International Nuclear Information System (INIS)

    Sullivan, R.J.

    1986-01-01

    Three, large-volume coverage manipulator systems were designed and built for the Defense Water Processing Facility at the Savannah River Laboratory. These stainless steel systems will be used for high-pressure spray decontamination of waste containers and large process equipment modules. Each system has a manipulator arm, folding boom, and vertical drive and guide structure. Handling capacity is 45 kg, horizontal reach is 4.6 m with a 180-deg swing motion, and the vertical travel is 6 m. The system is remotely removable and replaceable in modules using an overhead crane and an impact wrench. The manipulator arm has seven motions: Shoulder rotation and pivot, elbow pivot, wrist pivot and rotation, and grip open-close. All motions are variable speed and are slip-clutch protected to prevent overloading from external forces (collisions)

  9. The effect of gap width on viscous stresses within the leakage across a bileaflet valve pivot

    DEFF Research Database (Denmark)

    Travis, Brandon R; Andersen, Morten E; Fründ, Ernst Torben

    2008-01-01

    reported within the pivots in previous studies. Velocities measured experimentally were even larger than those estimated computationally. CONCLUSION: These experiments suggest that viscous stresses in leakage flow across a bileaflet mitral valve increase with gap width, and may contribute more to blood...

  10. Arming shoes of the fifteenth century

    Directory of Open Access Journals (Sweden)

    Volken Marquita

    2017-12-01

    Full Text Available Military footwear for the fifteenth century includes arming shoes worn under sabatons. Written sources suggest arming shoes and footwear used for fighting were ordinary shoes adapted for the purpose. Archaeological footwear was examined for signs of such modifications. Medieval shoe technology is presented, showing the range of footwear and its uses and gait biomechanics. Based on experiences from re-enactors wearing armours, medieval shoe styles are discussed for appropriateness as arming shoes. The question of why medieval military footwear shows no purposed development is addressed.

  11. Wastewater heat recovery method and apparatus

    Science.gov (United States)

    Kronberg, J.W.

    1991-01-01

    This invention is comprised of a heat recovery system with a heat exchanger and a mixing valve. A drain trap includes a heat exchanger with an inner coiled tube, baffle plate, wastewater inlet, wastewater outlet, cold water inlet, and preheated water outlet. Wastewater enters the drain trap through the wastewater inlet, is slowed and spread by the baffle plate, and passes downward to the wastewater outlet. Cold water enters the inner tube through the cold water inlet and flows generally upward, taking on heat from the wastewater. This preheated water is fed to the mixing valve, which includes a flexible yoke to which are attached an adjustable steel rod, two stationary zinc rods, and a pivoting arm. The free end of the arm forms a pad which rests against a valve seat. The rods and pivoting arm expand or contract as the temperature of the incoming preheated water changes. The zinc rods expand more than the steel rod, flexing the yoke and rotating the pivoting arm. The pad moves towards the valve seat as the temperature of the preheated water rises, and away as the temperature falls, admitting a variable amount of hot water to maintain a nearly constant average process water temperature.

  12. Wastewater heat recovery apparatus

    Science.gov (United States)

    Kronberg, J.W.

    1992-09-01

    A heat recovery system is described with a heat exchanger and a mixing valve. A drain trap includes a heat exchanger with an inner coiled tube, baffle plate, wastewater inlet, wastewater outlet, cold water inlet, and preheated water outlet. Wastewater enters the drain trap through the wastewater inlet, is slowed and spread by the baffle plate, and passes downward to the wastewater outlet. Cold water enters the inner tube through the cold water inlet and flows generally upward, taking on heat from the wastewater. This preheated water is fed to the mixing valve, which includes a flexible yoke to which are attached an adjustable steel rod, two stationary zinc rods, and a pivoting arm. The free end of the arm forms a pad which rests against a valve seat. The rods and pivoting arm expand or contract as the temperature of the incoming preheated water changes. The zinc rods expand more than the steel rod, flexing the yoke and rotating the pivoting arm. The pad moves towards the valve seat as the temperature of the preheated water rises, and away as the temperature falls, admitting a variable amount of hot water to maintain a nearly constant average process water temperature. 6 figs.

  13. Level of Agreement Between Forearm and Upper Arm Blood Pressure Measurements in Patients With Large Arm Circumference.

    Science.gov (United States)

    Watson, Sheri; Aguas, Marita; Colegrove, Pat; Foisy, Nancy; Jondahl, Bonnie; Anastas, Zoe

    2017-02-01

    The purpose of the study was to determine if forearm blood pressures (BPs) measured in three different locations agree with the recommended upper arm location for noninvasive BP measurement. A method-comparison design was used. In a convenience sample of postanesthesia care unit patients with large upper arm circumference, BP's were obtained in three different forearm locations (lower forearm, middle forearm, and upper forearm) and compared to upper arm BP using an automated BP measuring device. The level of agreement (bias ± precision) between each forearm location and the upper arm BP was calculated using standard formulas. Acceptable levels of agreement based on expert opinion were set a priori at bias and precision values of less than ±5 mm Hg (bias) and ±8 mm Hg (precision). Forty-eight postanesthesia patients participated in the study. Bias and precision values were found to exceed the acceptable level of agreement for all but one of the systolic and diastolic BP comparisons in the three forearm BP locations. Fifty-six percent of all patients studied had one or more BP difference of at least 10 mm Hg in each of the three forearm locations, with 10% having one or more differences of at least 20 mm Hg. The differences in forearm BP measurements observed in this study indicate that the clinical practice of using a forearm BP with a regular-sized BP cuff in place of a larger sized BP cuff placed on the upper arm in postanesthesia care unit patients with large arm circumferences is inappropriate. The BPs obtained at the forearm location are not equivalent to the BPs obtained at the upper arm location. Copyright © 2015 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  14. A new scheduling algorithm for parallel sparse LU factorization with static pivoting

    Energy Technology Data Exchange (ETDEWEB)

    Grigori, Laura; Li, Xiaoye S.

    2002-08-20

    In this paper we present a static scheduling algorithm for parallel sparse LU factorization with static pivoting. The algorithm is divided into mapping and scheduling phases, using the symmetric pruned graphs of L' and U to represent dependencies. The scheduling algorithm is designed for driving the parallel execution of the factorization on a distributed-memory architecture. Experimental results and comparisons with SuperLU{_}DIST are reported after applying this algorithm on real world application matrices on an IBM SP RS/6000 distributed memory machine.

  15. Pivotal Ways of Improving Leadership and the Scholarship of Learning and Teaching in Higher Education

    Science.gov (United States)

    Simon, Sue; Christie, Michael; Graham, Wayne A.; Call, Kairen

    2014-01-01

    This paper presents a new model of leadership that can improve the knowledge and skills needed by school leaders who undertake Masters of Business and Masters of Education. The model is called PIVOTAL which stands for Partnerships, Innovation and Vitality--Opportunities for Thriving Academic Leadership. The model is compared and contrasted with…

  16. Two-Armed, Mobile, Sensate Research Robot

    Science.gov (United States)

    Engelberger, J. F.; Roberts, W. Nelson; Ryan, David J.; Silverthorne, Andrew

    2004-01-01

    The Anthropomorphic Robotic Testbed (ART) is an experimental prototype of a partly anthropomorphic, humanoid-size, mobile robot. The basic ART design concept provides for a combination of two-armed coordination, tactility, stereoscopic vision, mobility with navigation and avoidance of obstacles, and natural-language communication, so that the ART could emulate humans in many activities. The ART could be developed into a variety of highly capable robotic assistants for general or specific applications. There is especially great potential for the development of ART-based robots as substitutes for live-in health-care aides for home-bound persons who are aged, infirm, or physically handicapped; these robots could greatly reduce the cost of home health care and extend the term of independent living. The ART is a fully autonomous and untethered system. It includes a mobile base on which is mounted an extensible torso topped by a head, shoulders, and two arms. All subsystems of the ART are powered by a rechargeable, removable battery pack. The mobile base is a differentially- driven, nonholonomic vehicle capable of a speed >1 m/s and can handle a payload >100 kg. The base can be controlled manually, in forward/backward and/or simultaneous rotational motion, by use of a joystick. Alternatively, the motion of the base can be controlled autonomously by an onboard navigational computer. By retraction or extension of the torso, the head height of the ART can be adjusted from 5 ft (1.5 m) to 6 1/2 ft (2 m), so that the arms can reach either the floor or high shelves, or some ceilings. The arms are symmetrical. Each arm (including the wrist) has a total of six rotary axes like those of the human shoulder, elbow, and wrist joints. The arms are actuated by electric motors in combination with brakes and gas-spring assists on the shoulder and elbow joints. The arms are operated under closed-loop digital control. A receptacle for an end effector is mounted on the tip of the wrist and

  17. Simulation of Octopus Arm Based on Coupled CPGs

    OpenAIRE

    Juan Tian; Qiang Lu

    2015-01-01

    The octopus arm has attracted many researchers’ interests and became a research hot spot because of its amazing features. Several dynamic models inspired by an octopus arm are presented to realize the structure with a large number of degrees of freedom. The octopus arm is made of a soft material introducing high-dimensionality, nonlinearity, and elasticity, which makes the octopus arm difficult to control. In this paper, three coupled central pattern generators (CPGs) are built and a 2-dimens...

  18. Kinematic decomposition and classification of octopus arm movements

    OpenAIRE

    Zelman, Ido; Titon, Myriam; Yekutieli, Yoram; Hanassy, Shlomi; Hochner, Binyamin; Flash, Tamar

    2013-01-01

    The octopus arm is a muscular hydrostat and due to its deformable and highly flexible structure it is capable of a rich repertoire of motor behaviors. Its motor control system uses planning principles and control strategies unique to muscular hydrostats. We previously reconstructed a data set of octopus arm movements from records of natural movements using a sequence of 3D curves describing the virtual backbone of arm configurations. Here we describe a novel representation of octopus arm move...

  19. The inter-arm diastolic blood pressure difference induced by one arm ischemia: a new approach to assess vascular endothelia function.

    Science.gov (United States)

    Hu, Weitong; Li, Juxiang; Su, Hai; Wang, Jiwei; Xu, Jinsong; Liu, Yanna; Huang, Ming; Cheng, Xiaoshu

    2014-01-01

    To evaluate whether inter-arm diastolic blood pressure difference (DBPl-r) induced by one arm ischemia correlates with flow-mediated dilatation (FMD). Bilateral arm BPs were simultaneously measured with two automatic devices and right brachial artery diameter (D) was measured by ultrasound technique in 108 subjects (56 hypertensives and 52 normotensives). Following baseline diameter (D0) and BP measurement, right brachial artery was occluded for 5 minutes. The diameter was measured at 1, 1.5 and 2 min, and bilateral BPs measured at 3, 4 and 5 min after occlusion release. Their averages were recorded as post-D and post-BP, respectively. The difference between post-D and D0 (ΔD) was calculated as the percentage increase of artery diameter (ΔD/D0). The BP difference between left and right arms was calculated as BPl-r, and the difference of post- BPl-r and baseline BPl-r was recorded as the net change of BPl-r (ΔBPl-r). At baseline, bilateral SBPs and DBPs were similar. Right arm ischemia induced significant DBP decline only in the right arm (68.8±12.7 vs 72.6±12.0 mmHg, Parm DBP difference induced by one arm ischemia may be a potential index for clinical evaluation of vascular endothelial function.

  20. Robust coordinated control of a dual-arm space robot

    Science.gov (United States)

    Shi, Lingling; Kayastha, Sharmila; Katupitiya, Jay

    2017-09-01

    Dual-arm space robots are more capable of implementing complex space tasks compared with single arm space robots. However, the dynamic coupling between the arms and the base will have a serious impact on the spacecraft attitude and the hand motion of each arm. Instead of considering one arm as the mission arm and the other as the balance arm, in this work two arms of the space robot perform as mission arms aimed at accomplishing secure capture of a floating target. The paper investigates coordinated control of the base's attitude and the arms' motion in the task space in the presence of system uncertainties. Two types of controllers, i.e. a Sliding Mode Controller (SMC) and a nonlinear Model Predictive Controller (MPC) are verified and compared with a conventional Computed-Torque Controller (CTC) through numerical simulations in terms of control accuracy and system robustness. Both controllers eliminate the need to linearly parameterize the dynamic equations. The MPC has been shown to achieve performance with higher accuracy than CTC and SMC in the absence of system uncertainties under the condition that they consume comparable energy. When the system uncertainties are included, SMC and CTC present advantageous robustness than MPC. Specifically, in a case where system inertia increases, SMC delivers higher accuracy than CTC and costs the least amount of energy.

  1. Bilateral movements increase sustained extensor force in the paretic arm.

    Science.gov (United States)

    Kang, Nyeonju; Cauraugh, James H

    2018-04-01

    Muscle weakness in the extensors poststroke is a common motor impairment. Unfortunately, research is unclear on whether bilateral movements increase extensor force production in the paretic arm. This study investigated sustained force production while stroke individuals maximally extended their wrist and fingers on their paretic arm. Specifically, we determined isometric force production in three conditions: (a) unilateral paretic arm, (b) unilateral nonparetic arm, and (c) bilateral (both arms executing the same movement simultaneously). Seventeen chronic stroke patients produced isometric sustained force by executing wrist and fingers extension in unilateral and bilateral contraction conditions. Mean force, force variability (coefficient of variation), and signal-to-noise ratio were calculated for each contraction condition. Analysis of two-way (Arm × Type of Condition: 2 × 2; Paretic or Nonparetic Arm × Unilateral or Bilateral Conditions) within-subjects ANOVAs revealed that the bilateral condition increased sustained force in the paretic arm, but reduced sustained force in the nonparetic arm. Further, although the paretic arm exhibited more force variability and less signal-to-noise ratio than the nonparetic arm during a unilateral condition, there were no differences when participants simultaneously executed isometric contractions with both arms. Our unique findings indicate that bilateral contractions transiently increased extensor force in the paretic arm. Implications for Rehabilitation Bilateral movements increased isometric wrsit extensor force in paretic arms and redcued force in nonparetic arms versus unilateral movements. Both paretic and nonparetic arms produced similar force variability and signal-to-noise ratio during bilateral movements. Increased sustained force in the paretic arm during the bilateral condition indicates that rehabilitation protocols based on bilateral movements may be beneficial for functional recovery.

  2. Prognostic significance of between-arm blood pressure differences.

    Science.gov (United States)

    Agarwal, Rajiv; Bunaye, Zerihun; Bekele, Dagim M

    2008-03-01

    Blood pressure (BP) recordings often differ between arms, but the extent to which these differences are reproducible and whether the differences have prognostic importance is unknown. We enrolled 421 consecutive patients from a medicine and a renal clinic at a veterans' hospital. Three BP recordings were obtained in each arm using an oscillometric device in a sequential manner and repeated in 1 week. Patients were followed for all-cause mortality arm had 5.1-mm Hg higher systolic BP that attenuated by approximately 2.2 mm Hg a week later. Systolic BP dropped 6.9 mm Hg over 1 week and by an additional 5.3 mm Hg in patients with chronic kidney disease. Accounting for the visit and arm effect improved the reproducibility of the BP measurements. The intraclass correlation coefficient was 0.74, which improved to 0.88 after accounting for visit and 0.93 after accounting for arm. The crude mortality rate was 6.33 per 100 patient-years. Every 10-mm Hg difference in systolic BP between the arms conferred a mortality hazard of 1.24 (95% CI: 1.01 to 1.52) after adjusting for average systolic BP and chronic kidney disease. BP differences between arms are reproducible and carry prognostic information. Patients should have evaluation of BP in both arms at the screening visit.

  3. Nuclear Arms Race and Environment

    OpenAIRE

    Li, Anpeng

    2012-01-01

    This paper introduces a new factor, environment, into nuclear arms race model. In this model, nuclear weapons produce larger defense power compared with conventional arms, but hurt the environment meanwhile. In the global welfare maximum level, both conventional and nuclear weapons budget are zero. However, the competitive equilibrium may not achieve the optimum. I give the condition to jump out of the prisoner's dilemma.

  4. Planet-driven Spiral Arms in Protoplanetary Disks. I. Formation Mechanism

    Science.gov (United States)

    Bae, Jaehan; Zhu, Zhaohuan

    2018-06-01

    Protoplanetary disk simulations show that a single planet can excite more than one spiral arm, possibly explaining the recent observations of multiple spiral arms in some systems. In this paper, we explain the mechanism by which a planet excites multiple spiral arms in a protoplanetary disk. Contrary to previous speculations, the formation of both primary and additional arms can be understood as a linear process when the planet mass is sufficiently small. A planet resonantly interacts with epicyclic oscillations in the disk, launching spiral wave modes around the Lindblad resonances. When a set of wave modes is in phase, they can constructively interfere with each other and create a spiral arm. More than one spiral arm can form because such constructive interference can occur for different sets of wave modes, with the exact number and launching position of the spiral arms being dependent on the planet mass as well as the disk temperature profile. Nonlinear effects become increasingly important as the planet mass increases, resulting in spiral arms with stronger shocks and thus larger pitch angles. This is found to be common for both primary and additional arms. When a planet has a sufficiently large mass (≳3 thermal masses for (h/r) p = 0.1), only two spiral arms form interior to its orbit. The wave modes that would form a tertiary arm for smaller mass planets merge with the primary arm. Improvements in our understanding of the formation of spiral arms can provide crucial insights into the origin of observed spiral arms in protoplanetary disks.

  5. Evaluation of arm-leg coordination in flat breaststroke.

    Science.gov (United States)

    Chollet, D; Seifert, L; Leblanc, H; Boulesteix, L; Carter, M

    2004-10-01

    This study proposes a new method to evaluate arm-leg coordination in flat breaststroke. Five arm and leg stroke phases were defined with a velocity-video system. Five time gaps quantified the time between arm and leg actions during three paces of a race (200 m, 100 m and 50 m) in 16 top level swimmers. Based on these time gaps, effective glide, effective propulsion, effective leg insweep and effective recovery were used to identify the different stroke phases of the body. A faster pace corresponded to increased stroke rate, decreased stroke length, increased propulsive phases, shorter glide phases, and a shorter T1 time gap, which measured the effective body glide. The top level swimmers showed short time gaps (T2, T3, T4, measuring the timing of arm-leg recoveries), which reflected the continuity in arm and leg actions. The measurement of these time gaps thus provides a pertinent evaluation of swimmers' skill in adapting their arm-leg coordination to biomechanical constraints.

  6. Ray tracing reconstruction investigation for C-arm tomosynthesis

    Science.gov (United States)

    Malalla, Nuhad A. Y.; Chen, Ying

    2016-04-01

    C-arm tomosynthesis is a three dimensional imaging technique. Both x-ray source and the detector are mounted on a C-arm wheeled structure to provide wide variety of movement around the object. In this paper, C-arm tomosynthesis was introduced to provide three dimensional information over a limited view angle (less than 180o) to reduce radiation exposure and examination time. Reconstruction algorithms based on ray tracing method such as ray tracing back projection (BP), simultaneous algebraic reconstruction technique (SART) and maximum likelihood expectation maximization (MLEM) were developed for C-arm tomosynthesis. C-arm tomosynthesis projection images of simulated spherical object were simulated with a virtual geometric configuration with a total view angle of 40 degrees. This study demonstrated the sharpness of in-plane reconstructed structure and effectiveness of removing out-of-plane blur for each reconstruction algorithms. Results showed the ability of ray tracing based reconstruction algorithms to provide three dimensional information with limited angle C-arm tomosynthesis.

  7. Defining and comparing learning actions in two simulation modalities: students training on a latex arm and each other's arms.

    Science.gov (United States)

    Ravik, Monika; Havnes, Anton; Bjørk, Ida Torunn

    2017-12-01

    To explore, describe and compare learning actions that nursing students used during peripheral vein cannulation training on a latex arm or each other's arms in a clinical skills centre. Simulation-based training is thought to enhance learning and transfer of learning from simulation to the clinical setting and is commonly recommended in nursing education. What students actually are doing during simulation-based training is, however, less explored. The analysis of learning actions used during simulation-based training could contribute to development and improvement of simulation as a learning strategy in nursing education. A qualitative explorative and descriptive research design, involving content analysis of video recordings, was used. Video-supported observation of nine nursing students practicing vein cannulation was conducted in a clinical skills centre in late 2012. The students engaged in various learning actions. Students training on a latex arm used a considerably higher number of learning actions relative to those training on each other's arms. In both groups, students' learning actions consisted mainly of seeking and giving support. The teacher provided students training on each other's arms with detailed feedback regarding insertion of the cannula into the vein, while those training on a latex arm received sparse feedback from the teacher and fellow students. The teacher played an important role in facilitating nursing students' practical skill learning during simulation. The provision of support from both teachers and students should be emphasised to ensure that nursing students' learning needs are met. This study suggest that student nurses may be differently and inadequately prepared in peripheral vein cannulation in two simulation modalities used in the academic setting; training on a latex arm and on each other's arms. © 2017 John Wiley & Sons Ltd.

  8. Perturb and Observe Control for an Embedded Point Pivoted Absorber

    Directory of Open Access Journals (Sweden)

    Gianluca Brando

    2016-11-01

    Full Text Available Marine energy sources represent an attractive and inexhaustible reservoir able to contribute to the fulfillment of the world energy demand in accordance with climate/energy regulatory frameworks. Wave energy converter (WEC integration into the main grid requires both the maximization of the harvested energy and the proper management of the generation variability. The present paper focuses on both these mentioned issues. More specifically, it presents an embedded point pivoted absorber (PPA and its related control strategy aimed at maximizing the harvested energy. Experimental and numerical investigations have been carried out in a wave/towing tank facility in order to derive the design characteristics of the full-scale model and demonstrate the validity and effectiveness of the proposed control strategy.

  9. Behavioral Cusps: A Person-Centered Concept for Establishing Pivotal Individual, Family, and Community Behaviors and Repertoires

    Science.gov (United States)

    Smith, Garnett J.; McDougall, Dennis; Edelen-Smith, Patricia

    2006-01-01

    Cumulative-hierarchical learning (CHL) and behavior, a premise first introduced by Staats in 1975, describes how higher-level behavioral patterns and structures can emerge from interactions among a set of lower-level actions. Proponents of CHL emphasize the importance of pivotal response interventions, behavior repertoires, generative learning,…

  10. Kinematic decomposition and classification of octopus arm movements.

    Science.gov (United States)

    Zelman, Ido; Titon, Myriam; Yekutieli, Yoram; Hanassy, Shlomi; Hochner, Binyamin; Flash, Tamar

    2013-01-01

    The octopus arm is a muscular hydrostat and due to its deformable and highly flexible structure it is capable of a rich repertoire of motor behaviors. Its motor control system uses planning principles and control strategies unique to muscular hydrostats. We previously reconstructed a data set of octopus arm movements from records of natural movements using a sequence of 3D curves describing the virtual backbone of arm configurations. Here we describe a novel representation of octopus arm movements in which a movement is characterized by a pair of surfaces that represent the curvature and torsion values of points along the arm as a function of time. This representation allowed us to explore whether the movements are built up of elementary kinematic units by decomposing each surface into a weighted combination of 2D Gaussian functions. The resulting Gaussian functions can be considered as motion primitives at the kinematic level of octopus arm movements. These can be used to examine underlying principles of movement generation. Here we used combination of such kinematic primitives to decompose different octopus arm movements and characterize several movement prototypes according to their composition. The representation and methodology can be applied to the movement of any organ which can be modeled by means of a continuous 3D curve.

  11. DMPD: Pivotal role of PGE2 and IL-10 in the cross-regulation of dendritic cell-derivedinflammatory mediators. [Dynamic Macrophage Pathway CSML Database

    Lifescience Database Archive (English)

    Full Text Available l) (.csml) Show Pivotal role of PGE2 and IL-10 in the cross-regulation of dendritic cell-derivedinflammatory mediator...egulation of dendritic cell-derivedinflammatory mediators. Authors Harizi H, Gualde N. Publication Cell Mol ...16978535 Pivotal role of PGE2 and IL-10 in the cross-regulation of dendritic cell-derivedinflammatory mediat...ors. Harizi H, Gualde N. Cell Mol Immunol. 2006 Aug;3(4):271-7. (.png) (.svg) (.htm

  12. Star distribution in the Orion spiral arm

    International Nuclear Information System (INIS)

    Basharina, T.S.; Pavlovskaya, E.D.; Filippova, A.A.

    1985-01-01

    The structure of the Orion spiral arm is studied by numerical experiments, assuming that in each direction considered the star distribution along the line of sight is a combination of two Gaussian laws. The corresponding parameters are evaluated for four Milky Way fields; the bimodal laws now fit the observations by the chi 2 criterion. In the Orion arm the line-of-sight star densities follow asymmetric curves, steeper at the outer edge of the arm

  13. ARM Unmanned Aerial Systems Implementation Plan

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, Beat [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Ivey, Mark [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-11-01

    Recent advances in Unmanned Aerial Systems (UAS) coupled with changes in the regulatory environment for operations of UAS in the National Airspace increase the potential value of UAS to the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility. UAS include unmanned aerial vehicles (UAV) and tethered balloon systems (TBS). The roles UAVs and TBSs could play within the ARM Facility, particularly science questions they could help address, have been discussed in several workshops, reports, and vision documents, including: This document describes the implementation of a robust and vigorous program for use of UAV and TBS for the science missions ARM supports.

  14. Passive detection of nuclear-armed SLCMs

    International Nuclear Information System (INIS)

    Sagdeev, R.Z.; Prilutsky, O.F.; Frolov, V.A.

    1992-01-01

    Effective procedures have been developed, using national technical measures (photoreconnaissance satellites, radiointercept stations, etc.), for verification of reductions in land-based intercontinental ballistic missiles, such as marine-based ballistic missiles, and strategic bombers. However, there is agreement on procedures for verifying limitations of numbers of long-range nuclear-armed cruise missiles. The difficulties in developing such procedures are sometimes regarded (by opponents of nuclear disarmament) as a reason why cruise missiles based on ships and submarines ought not to be limited by future arms-reduction treaties. This paper considers the detectability of nuclear-armed cruise missiles through the penetrating radiation emitted spontaneously from their warheads

  15. Control of octopus arm extension by a peripheral motor program.

    Science.gov (United States)

    Sumbre, G; Gutfreund, Y; Fiorito, G; Flash, T; Hochner, B

    2001-09-07

    For goal-directed arm movements, the nervous system generates a sequence of motor commands that bring the arm toward the target. Control of the octopus arm is especially complex because the arm can be moved in any direction, with a virtually infinite number of degrees of freedom. Here we show that arm extensions can be evoked mechanically or electrically in arms whose connection with the brain has been severed. These extensions show kinematic features that are almost identical to normal behavior, suggesting that the basic motor program for voluntary movement is embedded within the neural circuitry of the arm itself. Such peripheral motor programs represent considerable simplification in the motor control of this highly redundant appendage.

  16. Technology and the arms race

    International Nuclear Information System (INIS)

    MacKenzie, D.

    1988-01-01

    This article makes a review of the book Innovation and the Arms Race: How the United States and the Soviet Union Develop New Military Technologies written by Matthew Evangelista. For at least the last two decades, scholars have struggled to come to grips with the role of technological change in the arms race. Possible relationships between theories on technology and politics are examined. The contrasts between U.S. and Soviet approaches are highlighted

  17. Optimizing Armed Forces Capabilities for Hybrid Warfare – New Challenge for Slovak Armed Forces

    Directory of Open Access Journals (Sweden)

    Peter PINDJÁK

    2015-09-01

    Full Text Available The paper deals with the optimization of military capabilities of the Slovak Armed Forces for conducting operations in a hybrid conflict, which represents one of the possible scenarios of irregular warfare. Whereas in the regular warfare adversaries intend to eliminate the centers of gravity of each other, most often command and control structures, in irregular conflicts, the center of gravity shifts towards the will and cognitive perception of the target population. Hybrid warfare comprises a thoroughly planned combination of conventional military approaches and kinetic operations with subversive, irregular activities, including information and cyber operations. These efforts are often accompanied by intensified activities of intelligence services, special operation forces, and even mercenary and other paramilitary groups. The development of irregular warfare capabilities within the Slovak Armed Forces will require a progressive transformation process that may turn the armed forces into a modern and adaptable element of power, capable of deployment in national and international crisis management operations.

  18. Simple model of the arms race

    International Nuclear Information System (INIS)

    Zane, L.I.

    1982-01-01

    A simple model of a two-party arms race is developed based on the principle that the race will continue so long as either side can unleash an effective first strike against the other side. The model is used to examine how secrecy, the ABM, MIRV-ing, and an MX system affect the arms race

  19. The new L4 gasoline engines with VALVEMATIC system

    Energy Technology Data Exchange (ETDEWEB)

    Harada, Jun; Yamada, Tetsu; Watanabe, Kenji [Toyota Motor Corporation, Aichi (Japan)

    2008-07-01

    Reduction of CO{sub 2} emissions is one of the major responsibilities of car manufacturers. It is an especially urgent task to develop new technologies with a simple, compact and widely applicable mechanism which can be used for middle class engines of mass volume production category. Toyota has developed a continuously variable valve timing and lift control system called 'VALVEMATIC'. By implementing this system fuel consumption can be improved by using smaller valve lift during low and middle engine loads (reduction of pumping loss by closing the intake valve earlier). The system consists of a special rocker arm which realizes continuously variable valve timing and lift. It is located between a conventional roller-rocker arm and the camshaft. An electrically actuated motor is used to control the lift and valve opening duration, while a hydraulically controlled variable valve timing mechanism (VVT-i) is also applied on both intake and exhaust cam shafts. The newly developed actuator contains Toyota's original planetary roller screw unit translating rotary movement of the motor into linear actuation. Thanks to the alignment of rocking center and actuator drive direction, a compact design has been achieved. In 2007, VALVEMATIC has been introduced into the Japanese market on a 2.0L engine (3ZR-FAE), which has the largest displacement of the ZR series. The engine employs a cam housing structure with valve train system separated from the cylinder head. The structure realized a high ratio of part commonization with the conventional engine, and an easy mounting of the VALVEMATIC-system by changing only the cam housing assembly. The engine achieved 5-10% fuel consumption improvement and good drivability by using a newly developed cooperative control of VALVEMATIC, VVT-i and the throttle valve. Maximum power also improved by approximately 11kW thanks to the maximized volumetric efficiency using VALVEMATIC. Furthermore, exhaust emissions were improved due to

  20. Kinematic decomposition and classification of octopus arm movements

    Directory of Open Access Journals (Sweden)

    Ido eZelman

    2013-05-01

    Full Text Available The octopus arm is a muscular hydrostat and due to its deformable and highly flexible structure it is capable of a rich repertoire of motor behaviors. Its motor control system uses planning principles and control strategies unique to muscular hydrostats. We previously reconstructed a data set of octopus arm movements from records of natural movements using a sequence of 3D curves describing the virtual backbone of arm configurations. Here we describe a novel representation of octopus arm movements in which a movement is characterized by a pair of surfaces that represent the curvature and torsion values of points along the arm as a function of time. This representation allowed us to explore whether the movements are built up of elementary kinematic units by decomposing each surface into a weighted combination of 2D Gaussian functions. The resulting Gaussian functions can be considered as motion primitives at the kinematic level of octopus arm movements. These can be used to examine underlying principles of movement generation. Here we used combination of such kinematic primitives to decompose different octopus arm movements and characterize several movement prototypes according to their composition. The representation and methodology can be applied to the movement of any organ which can be modeled by means of a continuous 3D curve.

  1. ATLAS software stack on ARM64

    CERN Document Server

    Smith, Joshua Wyatt; The ATLAS collaboration

    2016-01-01

    The ATLAS experiment explores new hardware and software platforms that, in the future, may be more suited to its data intensive workloads. One such alternative hardware platform is the ARM architecture, which is designed to be extremely power efficient and is found in most smartphones and tablets. CERN openlab recently installed a small cluster of ARM 64-bit evaluation prototype servers. Each server is based on a single-socket ARM 64-bit system on a chip, with 32 Cortex-A57 cores. In total, each server has 128 GB RAM connected with four fast memory channels. This paper reports on the port of the ATLAS software stack onto these new prototype ARM64 servers. This included building the "external" packages that the ATLAS software relies on. Patches were needed to introduce this new architecture into the build as well as patches that correct for platform specific code that caused failures on non-x86 architectures. These patches were applied such that porting to further platforms will need no or only very little adj...

  2. Does "hidden undercuffing" occur among obese patients? Effect of arm sizes and other predictors of the difference between wrist and upper arm blood pressures.

    Science.gov (United States)

    Doshi, Hardik; Weder, Alan B; Bard, Robert L; Brook, Robert D

    2010-02-01

    Arm size can affect the accuracy of blood pressure (BP) measurement, and "undercuffing" of large upper arms is likely to be a growing problem. Therefore, the authors investigated the relationship between upper arm and wrist readings. Upper arm and wrist circumferences and BP were measured in 261 consecutive patients. Upper arm auscultation and wrist BP was measured in triplicate, rotating measurements every 30 seconds between sites. Upper arm BP was 131.9+/-20.6/71.6+/-12.6 mm Hg in an obese population (body mass index, 30.6+/-6.6 kg/m(2)) with mean upper arm size of 30.7+/-5.1 cm. Wrist BP was higher (2.6+/-9.2 mm Hg and 4.9+/-6.6 mm Hg, respectively, PBlood Pressure (JNC 7) strata (kappa value=0.27-0.71), and the difference was >or=5 mm Hg in 72% of the patients. The authors conclude that there was poor concordance between arm and wrist BP measurement and found no evidence that "hidden undercuffing" was associated with obesity; therefore, they do not support routine use of wrist BP measurements.

  3. Arms control, nonproliferation, and US national security

    International Nuclear Information System (INIS)

    Pilat, J.F.

    1985-01-01

    The continuation of the arms race and the failure of arms control and disarmament negotiations lend support to the belief that US and Soviet power, prestige, and security depend upon nuclear weapons. Therefore, the argument goes, the non-nuclear-weapon states (particularly those that are not allied with nuclear-weapon states and do not share their nuclear shield) may conclude that they would be well served by possession of these weapons. In this sense, the failure of nuclear arms reductions could create incentives for further proliferation

  4. To Arm or Not to Arm: The Case Against Arming Vietnam and the Philippines

    Science.gov (United States)

    2015-04-13

    designed to allay 9 Leaf (accessed Oct 24, 2014). 10 Ankit Panda , “What to Expect if the U.S. Lifts...their animated populations. Despite the rhetoric, no ideology or nation is monolithic, thus opportunities exist to improve the U.S.-Sino...Joint Forces Quarterly 2 (2014): 76-80. Panda , Ankit. “What to Expect if the U.S. Lifts Its Vietnam Arms Embargo.” The Diplomat. September 29

  5. Experimental Evaluation of the Discharge Coefficient of a Centre-Pivot Roof Window

    DEFF Research Database (Denmark)

    Iqbal, Ahsan; Afshari, Alireza; Heiselberg, Per

    2013-01-01

    equation. This equation involves a discharge coefficient of the window. The value of the discharge coefficient is the major cause of erroneous estimation of airflow rates. This paper focuses on the experimental study of the discharge coefficient (CD) of a centre-pivot roof window. The measurements were...... performed in the energy flex house of the Technological Institute - Denmark. The discharge coefficient is evaluated for both inflows and outflows. It is concluded that the use of single value of CD for different flap opening angles is one of the cause of erroneous estimation. Likewise, the value of CD...

  6. Stellar complexes in spiral arms of galaxies

    Science.gov (United States)

    Efremov, Yu. N.

    The history of the introduction and development of the star complexes conception is briefly described. These large groups of stars were picked out and named as such ones in our Galaxy with argumentation and evidence for their physical unity (using the Cepheid variables the distances and ages of which are easy determined from their periods); anyway earlier the complexes were noted along the spiral arms of the Andromeda galaxy, but were not recognized as a new kind of star group. The chains of complexes along the spiral arms are observed quite rarely; their origin is explained by magneto- gravitational or purely gravitational instability developing along the arm. It is not clear why these chains are quite a rare phenomenon - and more so why sometimes the regular chain of complexes are observed in one arm only. Probably intergalactic magnetic field participated in formation of such chains. Apart from the complexes located along the arms, there are isolated giant complexes known (up to 700 pc in diameter) which look like super-gigantic but rather rarefied globular clusters. Until now only two of these formations are studied, in NGC 6946 and M51.

  7. Changing patterns of arms transfers

    International Nuclear Information System (INIS)

    Wulf, H.

    1998-01-01

    Three factors in the international system have been of importance for the trade of arms: the role of the main actors on the supply side and since 1970 on the demand side, the permanently increasing importance of economics, and the balance trade, industrial capacity and jobs in supplier countries and purchasing power of potential importers. Two political events in 1991 had lasting effect on the development of the trade in arms: the dissolution of Soviet Union and the Gulf War

  8. Driving pockels cells in multi-arm lasers

    International Nuclear Information System (INIS)

    Carder, B.M.

    1978-01-01

    This paper describes the method used to drive Pockels cells on the 20-arm Shiva laser for inertial confinement fusion research at the Lawrence Livermore Laboratory. Shiva became operational last fall, and has just completed a series of 20-arm target shots. It uses two pockels cell gates in each laser arm for suppression of amplified spontaneous emission (ASE) that can damage or destroy the target before the main pulse arrives. Two additional Pockels cells are used in the preamplification stages, so that a total of 42 cells must be driven by the pulser system

  9. Comparative study regarding physical characteristics at male handball players activating on wing and pivot positions at Romanian team Steaua Bucharest

    Directory of Open Access Journals (Sweden)

    Ioana-Maria CURIŢIANU

    2017-02-01

    Full Text Available Aim and purpose. The main purpose of this article was to evaluate the differences between physical characteristics at wings and pivots (nine subjects, male handball experienced players, from Romanian handball team Steaua Bucharest, previous to their participation in the Romanian National League, competitive season 2013-2014. Material and methods. In order to achieve this research on the motric evaluation of the players that activate in the 6m. line at team Steaua Bucharest, that activates in Romanian National League, before competitive season 2013-2014, we used the following research methods: literature review, testing method conducted by using five control samples in order to establish the physical qualities of the handball players understudy, the data collected was used to analyze the motric performance of wing and pivot players; the statistical and mathematical method was used to underline the differences between the players that activate in the three positions on the team. Results. The interpretation of the results led to establishing the differences in terms of physical qualities between 6m line players from Romanian male handball team Steaua Bucharest. Results revealed that there are no significant differences in terms of physical qualities between wing players and pivot players. Conclusions. After processing and interpretation of results we can state that the performance of the 6m. line players of the Romanian team understudy was a good one with no significant differences between the results obtained by wings and pivots at the battery of tests (five tests but after this analysis, coaches could perfect their training program in order to achieve better physical results because it is known that motivation, tactics and technical skills play a far more important role in team sports than any other characteristics, but without a good physical training these abilities are incomplete.

  10. System containing a safety disk

    International Nuclear Information System (INIS)

    Schupp, W.

    1975-01-01

    The safety element is not overdimensioned at pressures between 2 and 150 atmospheric excess pressure. Therefore the flat bursting disc is mounted within a supporting and stopping holding and the rated breaking point is covered by a supporting body. Its outer diameter sufficiently overlaps the recesses on both sides of the rated breaking point. It absorbs the total load given by the operating pressure. Only a release mechanism with slide wedge, eccentric disc, magnet, and rocker arm releases the supporting body, e.g. if the blow-down pressure is reached, so that the operating pressure may work on the bursting disc. An insulated copper wire layed in the breaking region within the bursting disc in case of shearing off signalizes the instant of failing of the breaking point because of current interruption. (DG) [de

  11. Energy Optimal Trajectories in Human Arm Motion Aiming for Assistive Robots

    Directory of Open Access Journals (Sweden)

    Lelai Zhou

    2017-01-01

    Full Text Available The energy expenditure in human arm has been of great interests for seeking optimal human arm trajectories. This paper presents a new way for calculating metabolic energy consumption of human arm motions. The purpose is to reveal the relationship between the energy consumption and the trajectory of arm motion, and further, the acceleration and arm orientation contributions. Human arm motion in horizontal plane is investigated by virtue of Qualisys motion capture system. The motion data is post-processed by a biomechanical model to obtain the metabolic expenditure. Results on the arm motion kinematics, dynamics and metabolic energy consumption, are included.

  12. Effect of standard cuff on blood pressure readings in patients with obese arms. How frequent are arms of a 'large circumference'?

    Science.gov (United States)

    Fonseca-Reyes, Salvador; de Alba-García, Javier García; Parra-Carrillo, José Z; Paczka-Zapata, José Antonio

    2003-06-01

    To measure the effect on blood pressure readings when a standard cuff is used on patients with arms of a large circumference, and to determine the frequency of arms of a large circumference. Blood pressures were taken in 120 subjects with an arm circumference greater than 33 cm. Also, the arm circumference was determined in 244 patients from a family health unit, and in 216 patients from a hypertension clinic. A mercury sphygmomanometer and two different cuff sizes were used in a random sequence; therefore, 60 patients' blood pressure were first measured with a large cuff, followed by a standard cuff; the opposite sequence was then applied for another 60 patients. With the obtained values and using a regression analysis, the difference in blood pressure overestimation was calculated. Arm circumference measurement percentages were used to determine the frequency of arms of a large circumference. Both systolic and diastolic blood pressures were significantly greater when the standard cuff was used. For every 5 cm increase in arm circumference, starting at 35 cm, a 2-5 mmHg increase in systolic blood pressure, and a 1-3 mmHg increase in diastolic blood pressure was observed. The prevalence of arms with a large circumference in the family medicine unit and hypertension clinic was 42% and 41.8%, respectively. There is an overestimation of blood pressure when a standard cuff is used in obese subjects. The high prevalence of these individuals in our environment, both in the hypertensive and normotensive population, makes it necessary to have on hand different sizes of cuffs for taking blood pressure in order to avoid incorrect decisions.

  13. Robots testing robots: ALAN-Arm, a humanoid arm for the testing of robotic rehabilitation systems.

    Science.gov (United States)

    Brookes, Jack; Kuznecovs, Maksims; Kanakis, Menelaos; Grigals, Arturs; Narvidas, Mazvydas; Gallagher, Justin; Levesley, Martin

    2017-07-01

    Robotics is increasing in popularity as a method of providing rich, personalized and cost-effective physiotherapy to individuals with some degree of upper limb paralysis, such as those who have suffered a stroke. These robotic rehabilitation systems are often high powered, and exoskeletal systems can attach to the person in a restrictive manner. Therefore, ensuring the mechanical safety of these devices before they come in contact with individuals is a priority. Additionally, rehabilitation systems may use novel sensor systems to measure current arm position. Used to capture and assess patient movements, these first need to be verified for accuracy by an external system. We present the ALAN-Arm, a humanoid robotic arm designed to be used for both accuracy benchmarking and safety testing of robotic rehabilitation systems. The system can be attached to a rehabilitation device and then replay generated or human movement trajectories, as well as autonomously play rehabilitation games or activities. Tests of the ALAN-Arm indicated it could recreate the path of a generated slow movement path with a maximum error of 14.2mm (mean = 5.8mm) and perform cyclic movements up to 0.6Hz with low gain (<1.5dB). Replaying human data trajectories showed the ability to largely preserve human movement characteristics with slightly higher path length and lower normalised jerk.

  14. Molecular clouds in the Carina arm - the largest objects, associated regions of star formation, and the Carina arm in the Galaxy

    International Nuclear Information System (INIS)

    Grabelsky, D.A.; Cohen, R.S.; Bronfman, L.; Thaddeus, P.

    1988-01-01

    The Columbia CO survey of the southern Galactic plane is used to identify giant molecular clouds and cloud complexes in the Vela-Carina-Centaurus section of the Galaxy. Twenty-seven giant molecular clouds between l = 270 and 300 deg are catalogued and their heliocentric distances given. In addition, 16 clouds at l greater than 300 deg beyond the solar circle extend the catalog to include the very distant portion of the Carina arm. The most massive clouds in the catalog trace the Carina arm over 23 kpc in the plane of the Galaxy. The average mass of these objects is 1.4 x 10 to the 6th solar, and their average spacing along the arm is 700 pc. The composite distribution projected onto the Galactic plane of the largest molecular clouds in the Carina arm and of similarly massive clouds in the first and second quadrants strongly suggests that the Carina and Sagittarius arms form a single spiral arm about 40 kpc in length wrapping two-thirds of the way around the Galaxy. Descriptions of each cloud, including identification of associated star-forming regions, are presented in an appendix. 76 references

  15. Inertial sensors to quantify the pivot shift test in the treatment of anterior cruciate ligament injury

    Science.gov (United States)

    ZAFFAGNINI, STEFANO; LOPOMO, NICOLA; SIGNORELLI, CECILIA; MUCCIOLI, GIULIO MARIA MARCHEGGIANI; BONANZINGA, TOMMASO; GRASSI, ALBERTO; RAGGI, FEDERICO; VISANI, ANDREA; MARCACCI, MAURILIO

    2014-01-01

    The main purpose of this article was to describe in detail, from the perspective of the clinical end user, a previously presented non-invasive methodology, applied in the treatment of anterior cruciate ligament injury, in which inertial sensors are used to quantify the pivot shift test. The outcomes obtained and relative considerations were compared with findings emerging from a review of the relevant updated literature. The detailed description here provided covers the system, the parameters identified and the testing procedure; it also includes the technical specifications of the hardware, the features introduced in the updated version of the software and the application of the system in clinical practice. The comparison of the technical considerations and clinical results with the updated literature confirmed the system’s optimal ergonomics, good reproducibility and clinical reliability. The novel approach here analyzed has been shown to overcome the weaknesses of other available devices and systems. Therefore, since it can be considered a new paradigm in the quantification of pivot shift test, we can recommend its routine use in clinical practice. PMID:25606555

  16. A Unified Approach for Reporting ARM Measurement Uncertainties Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Campos, E [Argonne National Lab. (ANL), Argonne, IL (United States); Sisterson, Douglas [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-12-01

    The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility is observationally based, and quantifying the uncertainty of its measurements is critically important. With over 300 widely differing instruments providing over 2,500 datastreams, concise expression of measurement uncertainty is quite challenging. The ARM Facility currently provides data and supporting metadata (information about the data or data quality) to its users through a number of sources. Because the continued success of the ARM Facility depends on the known quality of its measurements, the Facility relies on instrument mentors and the ARM Data Quality Office (DQO) to ensure, assess, and report measurement quality. Therefore, an easily accessible, well-articulated estimate of ARM measurement uncertainty is needed. Note that some of the instrument observations require mathematical algorithms (retrievals) to convert a measured engineering variable into a useful geophysical measurement. While those types of retrieval measurements are identified, this study does not address particular methods for retrieval uncertainty. As well, the ARM Facility also provides engineered data products, or value-added products (VAPs), based on multiple instrument measurements. This study does not include uncertainty estimates for those data products. We propose here that a total measurement uncertainty should be calculated as a function of the instrument uncertainty (calibration factors), the field uncertainty (environmental factors), and the retrieval uncertainty (algorithm factors). The study will not expand on methods for computing these uncertainties. Instead, it will focus on the practical identification, characterization, and inventory of the measurement uncertainties already available in the ARM community through the ARM instrument mentors and their ARM instrument handbooks. As a result, this study will address the first steps towards reporting ARM measurement uncertainty

  17. Putting the Glare of Publicity on International Arms Sales.

    Science.gov (United States)

    Hartman, William

    1992-01-01

    Reports on a United Nations committee recommendation that the Security Council establish a universal register of arms. Suggests that such a register would limit the destabilizing influence of major arms sales on developing nations. Argues that visibility of arms sales may help reduce their number. (DK)

  18. The Role of Ethics in International Arms Transfers

    Science.gov (United States)

    2016-06-01

    i THE ROLE OF ETHICS IN INTERNATIONAL ARMS TRANSFERS BY MAJOR ROB ARNETT A THESIS PRESENTED TO THE FACULTY OF THE SCHOOL OF...War’s Ends” provided the intellectual spark to explore the topic of ethics in international arms sales. Additionally, Dr. Murphy was kind enough to... ethics in American arms transfer policy to determine whether the Just War tradition’s jus ad bellum framework can help policymakers through a complex

  19. Arm to leg coordination in elite butterfly swimmers.

    Science.gov (United States)

    Chollet, D; Seifert, L; Boulesteix, L; Carter, M

    2006-04-01

    This study proposed the use of four time gaps to assess arm-to-leg coordination in the butterfly stroke at increasing race paces. Fourteen elite male swimmers swam at four velocities corresponding to the appropriate paces for, respectively, the 400-m, 200-m, 100-m, and 50-m events. The different stroke phases of the arm and leg were identified by video analysis and then used to calculate four time gaps (T1: time gap between entry of the hands in the water and the high break-even point of the first undulation; T2: time gap between the beginning of the hands' backward movement and the low break-even point of the first undulation; T3: time gap between the hands' arrival in a vertical plane to the shoulders and the high break-even point of the second undulation; T4: time gap between the hands' release from the water and the low break-even point of the second undulation), the values of which described the changing relationship of arm to leg movements over an entire stroke cycle. With increases in pace, elite swimmers increased the stroke rate, the relative duration of the arm pull, the recovery and the first downward movement of the legs, and decreased the stroke length, the relative duration of the arm catch phase and the body glide with arms forward (measured by T2), until continuity in the propulsive actions was achieved. Whatever the paces, the T1, T3, and T4 values were close to zero and revealed a high degree of synchronisation at key motor points of the arm and leg actions. This new method to assess butterfly coordination could facilitate learning and coaching by situating the place of the leg undulation in relation with the arm stroke.

  20. MPL-net at ARM Sites

    Science.gov (United States)

    Spinhirne, J. D.; Welton, E. J.; Campbell, J. R.; Berkoff, T. A.; Starr, David OC. (Technical Monitor)

    2002-01-01

    The NASA MPL-net project goal is consistent data products of the vertical distribution of clouds and aerosol from globally distributed lidar observation sites. The four ARM micro pulse lidars are a basis of the network to consist of over twelve sites. The science objective is ground truth for global satellite retrievals and accurate vertical distribution information in combination with surface radiation measurements for aerosol and cloud models. The project involves improvement in instruments and data processing and cooperation with ARM and other partners.

  1. Neurosurgical robotic arm drilling navigation system.

    Science.gov (United States)

    Lin, Chung-Chih; Lin, Hsin-Cheng; Lee, Wen-Yo; Lee, Shih-Tseng; Wu, Chieh-Tsai

    2017-09-01

    The aim of this work was to develop a neurosurgical robotic arm drilling navigation system that provides assistance throughout the complete bone drilling process. The system comprised neurosurgical robotic arm navigation combining robotic and surgical navigation, 3D medical imaging based surgical planning that could identify lesion location and plan the surgical path on 3D images, and automatic bone drilling control that would stop drilling when the bone was to be drilled-through. Three kinds of experiment were designed. The average positioning error deduced from 3D images of the robotic arm was 0.502 ± 0.069 mm. The correlation between automatically and manually planned paths was 0.975. The average distance error between automatically planned paths and risky zones was 0.279 ± 0.401 mm. The drilling auto-stopping algorithm had 0.00% unstopped cases (26.32% in control group 1) and 70.53% non-drilled-through cases (8.42% and 4.21% in control groups 1 and 2). The system may be useful for neurosurgical robotic arm drilling navigation. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Safeguarding arms control

    International Nuclear Information System (INIS)

    Flanagan, S.J.

    1988-01-01

    This essay reviews the evolution of various safeguards concepts associated with U.S. Soviet arms control negotiations over the past twenty-five years. It explore in some detail the origins, nature, and effectiveness of the safeguards packages associated with six agreements: the Limited Test Ban Treaty (1963), the SALT I Interim Agreement (1972), the Anti-Ballistic Missile (ABM) Treaty (1972), the Threshold Test Ban Treaty (1974), the Peaceful Nuclear Explosions Treaty (1976) and the SALT II Treaty (1979). Finally, the implications of this historical record for developing future nuclear and conventional arms control accords and for shoring up existing pacts, such as the ABM Treaty, are assessed with a view towards practicable prescriptions for Western policymakers. The treaty eliminating intermediate-range nuclear forces (INF) incorporates several verification safeguards, and it is very likely that analogous measures would be attached to any accord constraining conventional forces in Europe

  3. Manipulator arm for a nuclear reactor vessel inspection device

    International Nuclear Information System (INIS)

    1980-01-01

    A manipulator arm for a reactor vessel in-service inspection apparatus is adapted to transport a transducer array for ultrasonic examination of welds at any point in the vessel. The removal of the inspection device from the reactor vessel in an emergency presents a problem where a relatively long manipulator arm is used. This invention provides an improved arm with means for changing the normal orientation of the arm to a shorter one to permit safe removal of the inspection device from the reactor vessel. (author)

  4. A software radio platform based on ARM and FPGA

    Directory of Open Access Journals (Sweden)

    Yang Xin.

    2016-01-01

    Full Text Available The rapid rise in computational performance offered by computer systems has greatly increased the number of practical software radio applications. A scheme presented in this paper is a software radio platform based on ARM and FPGA. FPGA works as the coprocessor together with the ARM, which serves as the core processor. ARM is used for digital signal processing and real-time data transmission, and FPGA is used for synchronous timing control and serial-parallel conversion. A SPI driver for real-time data transmission between ARM and FPGA under ARM-Linux system is provided. By adopting modular design, the software radio platform is capable of implementing wireless communication functions and satisfies the requirements of real-time signal processing platform for high security and broad applicability.

  5. Natural Resource Extraction, Armed Violence, and Environmental Degradation.

    Science.gov (United States)

    Downey, Liam; Bonds, Eric; Clark, Katherine

    2010-12-01

    The goal of this article is to demonstrate that environmental sociologists cannot fully explain the relationship between humans and the natural world without theorizing a link between natural resource extraction, armed violence, and environmental degradation. The authors begin by arguing that armed violence is one of several overlapping mechanisms that provide powerful actors with the means to (a) prevail over others in conflicts over natural resources and (b) ensure that natural resources critical to industrial production and state power continue to be extracted and sold in sufficient quantities to promote capital accumulation, state power, and ecological unequal exchange. The authors then identify 10 minerals that are critical to the functioning of the U.S. economy and/or military and demonstrate that the extraction of these minerals often involves the use of armed violence. They further demonstrate that armed violence is associated with the activities of the world's three largest mining companies, with African mines that receive World Bank funding, and with petroleum and rainforest timber extraction. The authors conclude that the natural resource base on which industrial societies stand is constructed in large part through the use and threatened use of armed violence. As a result, armed violence plays a critical role in fostering environmental degradation and ecological unequal exchange.

  6. US-Russian relations: the arms control agenda

    International Nuclear Information System (INIS)

    Potter, W.

    2001-01-01

    At a time when US-Russian relations are widely regarded to be in a state of flux, it is appropriate to examine the degree of continuity and change in the sphere of nuclear arms control. More specifically, this brief essay identifies a number of propositions about nuclear weapons, arms control, and nonproliferation that increasingly reflect the conventional wisdom in Washington, although these propositions may be neither true nor wise; and assesses the prospects for arms control progress in the areas of strategic and non-strategic nuclear weapons and nonproliferation in light of these prevailing views. (author)

  7. US-Russian relations: the arms control agenda

    Energy Technology Data Exchange (ETDEWEB)

    Potter, W

    2001-07-01

    At a time when US-Russian relations are widely regarded to be in a state of flux, it is appropriate to examine the degree of continuity and change in the sphere of nuclear arms control. More specifically, this brief essay identifies a number of propositions about nuclear weapons, arms control, and nonproliferation that increasingly reflect the conventional wisdom in Washington, although these propositions may be neither true nor wise; and assesses the prospects for arms control progress in the areas of strategic and non-strategic nuclear weapons and nonproliferation in light of these prevailing views. (author)

  8. The inter-arm diastolic blood pressure difference induced by one arm ischemia: a new approach to assess vascular endothelia function.

    Directory of Open Access Journals (Sweden)

    Weitong Hu

    Full Text Available OBJECTIVES: To evaluate whether inter-arm diastolic blood pressure difference (DBPl-r induced by one arm ischemia correlates with flow-mediated dilatation (FMD. METHODS: Bilateral arm BPs were simultaneously measured with two automatic devices and right brachial artery diameter (D was measured by ultrasound technique in 108 subjects (56 hypertensives and 52 normotensives. Following baseline diameter (D0 and BP measurement, right brachial artery was occluded for 5 minutes. The diameter was measured at 1, 1.5 and 2 min, and bilateral BPs measured at 3, 4 and 5 min after occlusion release. Their averages were recorded as post-D and post-BP, respectively. The difference between post-D and D0 (ΔD was calculated as the percentage increase of artery diameter (ΔD/D0. The BP difference between left and right arms was calculated as BPl-r, and the difference of post- BPl-r and baseline BPl-r was recorded as the net change of BPl-r (ΔBPl-r. RESULTS: At baseline, bilateral SBPs and DBPs were similar. Right arm ischemia induced significant DBP decline only in the right arm (68.8±12.7 vs 72.6±12.0 mmHg, P<0.05, which led to an increase of ΔDBPl-r (4.00±3.75 vs 0.78±4.47 mmHg, P<0.05. A positive correlation was seen between ΔD/D0 and ΔDBPl-r (r = 0.744, p<0.001. Furthermore, the correlation between age and ΔDBPl-r (r = -0.358, P<0.01 was similar to that between age and D/D0 (r = -0.398, P<0.01. Meanwhile, both ΔDBPl-r and ΔD/D0 were significantly lower in hypertensive patients than in normotensive patients. CONCLUSION: The inter-arm DBP difference induced by one arm ischemia may be a potential index for clinical evaluation of vascular endothelial function.

  9. Technology-supported training of arm-hand skills in stroke

    NARCIS (Netherlands)

    Timmermans, A.A.A.

    2010-01-01

    Impaired arm-hand performance is a serious consequence of stroke that is associated with reduced self-efficacy and poor quality of life. Task-oriented arm training is a therapy approach that is known to improve skilled arm-hand performance, even in chronic stages after stroke. At the start of this

  10. Kinematic feedback control laws for generating natural arm movements

    International Nuclear Information System (INIS)

    Kim, Donghyun; Jang, Cheongjae; Park, Frank C

    2014-01-01

    We propose a stochastic optimal feedback control law for generating natural robot arm motions. Our approach, inspired by the minimum variance principle of Harris and Wolpert (1998 Nature 394 780–4) and the optimal feedback control principles put forth by Todorov and Jordan (2002 Nature Neurosci. 5 1226–35) for explaining human movements, differs in two crucial respects: (i) the endpoint variance is minimized in joint space rather than Cartesian hand space, and (ii) we ignore the dynamics and instead consider only the second-order differential kinematics. The feedback control law generating the motions can be straightforwardly obtained by backward integration of a set of ordinary differential equations; these equations are obtained exactly, without any linear–quadratic approximations. The only parameters to be determined a priori are the variance scale factors, and for both the two-DOF planar arm and the seven-DOF spatial arm, a table of values is constructed based on the given initial and final arm configurations; these values are determined via an optimal fitting procedure, and consistent with existing findings about neuromuscular motor noise levels of human arm muscles. Experiments conducted with a two-link planar arm and a seven-DOF spatial arm verify that the trajectories generated by our feedback control law closely resemble human arm motions, in the sense of producing nearly straight-line hand trajectories, having bell-shaped velocity profiles, and satisfying Fitts Law. (paper)

  11. Brain-Machine Interface Enables Bimanual Arm Movements in Monkeys

    Science.gov (United States)

    Ifft, Peter J.; Shokur, Solaiman; Li, Zheng; Lebedev, Mikhail A.; Nicolelis, Miguel A. L.

    2014-01-01

    Brain-machine interfaces (BMIs) are artificial systems that aim to restore sensation and movement to severely paralyzed patients. However, previous BMIs enabled only single arm functionality, and control of bimanual movements was a major challenge. Here, we developed and tested a bimanual BMI that enabled rhesus monkeys to control two avatar arms simultaneously. The bimanual BMI was based on the extracellular activity of 374–497 neurons recorded from several frontal and parietal cortical areas of both cerebral hemispheres. Cortical activity was transformed into movements of the two arms with a decoding algorithm called a 5th order unscented Kalman filter (UKF). The UKF is well-suited for BMI decoding because it accounts for both characteristics of reaching movements and their representation by cortical neurons. The UKF was trained either during a manual task performed with two joysticks or by having the monkeys passively observe the movements of avatar arms. Most cortical neurons changed their modulation patterns when both arms were engaged simultaneously. Representing the two arms jointly in a single UKF decoder resulted in improved decoding performance compared with using separate decoders for each arm. As the animals’ performance in bimanual BMI control improved over time, we observed widespread plasticity in frontal and parietal cortical areas. Neuronal representation of the avatar and reach targets was enhanced with learning, whereas pairwise correlations between neurons initially increased and then decreased. These results suggest that cortical networks may assimilate the two avatar arms through BMI control. PMID:24197735

  12. Inter-arm blood pressure differences in pregnant women.

    Science.gov (United States)

    Poon, L C Y; Kametas, N; Strobl, I; Pachoumi, C; Nicolaides, K H

    2008-08-01

    To determine the prevalence of blood pressure inter-arm difference (IAD) in early pregnancy and to investigate its possible association with maternal characteristics. A cross-sectional observational study. Routine antenatal visit in a university hospital. A total of 5435 pregnant women at 11-14 weeks of gestation. Blood pressure was taken from both arms simultaneously with a validated automated device. The presence of inter-arm blood pressure difference of 10 mmHg or more. The IAD in systolic and diastolic blood pressure was 10 mmHg or more in 8.3 and 2.3% of the women, respectively. Systolic IAD was found to be significantly related to systolic blood pressure and pulse pressure, and diastolic IAD was found to be significantly related to maternal age, diastolic blood pressure and pulse pressure. The systolic and diastolic IAD were higher in the hypertensive group compared with the normotensive group and absolute IAD increased with increasing blood pressure. About 31.0 and 23.9% of cases of hypertension would have been underreported if the left arm and the right arm were used, respectively, in measuring the blood pressure. There is a blood pressure IAD in a significant proportion of the pregnant population, and its prevalence increases with increasing blood pressure. By measuring blood pressure only on one arm, there is a one in three chance of underreporting hypertension. Therefore, it would be prudent that during the booking visit blood pressure should be taken in both arms and thus provide guidance for subsequent blood pressure measurements during the course of pregnancy.

  13. Industrial dual arm robot manipulator for precise assembly of mechanical parts

    Science.gov (United States)

    Park, Chanhun; Kim, Doohyung; Park, Kyoungtaik; Choi, Youngjin

    2007-12-01

    A new structure of dual arm robot manipulator which consists of two industrial 6-DOF arms and one 2-DOF Torso is introduced. Each industrial 6-DOF arm is able to be used as a stand-alone industrial 6-DOF robot manipulator and as a part of dual arm manipulator at the same time. These structures help the robot maker which is willing to succeed in the emerging dual arm robot market in order to have high competition for the current industrial robot market at same time. Self-collision detection algorithm for multi-arm robot and kinematics algorithms for the developed dual arm robot manipulator which are implemented in our controller are introduced.

  14. Primary design of Si cooling arm structure in ICF cryogenic target

    International Nuclear Information System (INIS)

    Zhang Yong; Yi Yong; Tang Changhuan; Zhang Jicheng

    2013-01-01

    According to the requirement of the cryogenic target system to the Si cooling arm structure, the Si cooling arm was primarily designed based on the USA National Ignition Facility (NIF) target. A new three-dimensional model of Si cooling arm was developed by SolidWorks software, and the simulation and analysis of Si cooling arm in aspect of mechanical property, thermal response and assembly were made based on the model. A law about the effect of the arm length of Si cooling arm and the width and the length of bifurcation on Si cooling arm was achieved. The research may provide the theoretical foundation and reference for the further improvement of cryogenic target. (authors)

  15. SIPRI's new conceptual approach to arms control and disarmament

    International Nuclear Information System (INIS)

    Rotfeld, Adam Daniel

    2000-01-01

    The end of the cold war deprioritized arms control and disarmament, and progress in the field was no longer a measure of relations among the major powers. In that context, the future of arms control and disarmament was discussed at the Nobel Symposium in October 1999. Stockholm International Peace Research Institute (SIPRI) views arms control as an instrument for shaping a new inclusive and cooperative security order. The author questions whether arms control challenges today can and should be resolved in the institutions established and the procedures elaborated in the bipolar framework. (author)

  16. Dual Arm Work Module Development and Appplications

    Energy Technology Data Exchange (ETDEWEB)

    Noakes, M.W.

    1999-04-25

    The dual arm work module (DAWM) was developed at Oak Ridge National Laboratory (ORNL) by the Robotics Technology Development Program (RTDP) as a development test bed to study issues related to dual arm manipulation, including platform cotilguration, controls, automation, operations, and tooling. The original platform was based on two Schilling Titan II manipulators mounted to a 5-degree-of- freedom (DOF) base fabricated by RedZone Robotics, Inc. The 5-DOF articulation provided a center torso rotation, linear actuation to change the separation between the arms, and arm base rotation joints to provide "elbows up," elbows down," or "elbows out" orientation. A series of tests were conducted on operations, tooling, and task space scene analysis (TSSA)-driven robotics for overhead transporter- mounted and crane hook-deployed scenarios. A concept was developed for DAWM deployment from a large remote work vehicle, but the project was redirected to support dismantlement of the Chicago Pile #5 (CP-5) reactor at Argonne National Laboratory in fiscal year (FY) 1997. Support of CP-5 required a change in focus of the dual arm technology from that of a development test bed to a system focussed for a specific end user. ORNL teamed with the Idaho National Environmental ,Engineering Laboratory, Sandia National Laboratory, and the Savannah River Technology Center to deliver a crane-deployed derivative of the DAWM, designated the dual arm work platform (DAWP). RTDP staff supported DAWP at CP-5 for one FY; Argonne staff continued operation through to dismantlement of the reactor internals. Lessons learned from this interaction were extensive. Beginning in FY 1999, dual arm development activities are again being pursued in the context of those lessons learned. This paper describes the progression of philosophy of the DAWM from initial test bed to lessons learned through interaction at CP-5 and to the present investigation of telerobotic assist of teleoperation and TSSA- driven robotics.

  17. ARM Enhanced Shortwave Experiment (ARESE) Solar Radiation Data

    Data.gov (United States)

    National Aeronautics and Space Administration — The ARM Enhanced Shortwave Experiment (ARESE) was conducted at the Department of Energy's ARM Southern Great Plains (SGP) Central Facility between September 22, 1995...

  18. Rosoboroneksport: Arms Sales and the Structure of Russian Defense Industry

    National Research Council Canada - National Science Library

    Blank, Stephen J

    2007-01-01

    In August 2006, the U.S. Government imposed sanctions on Russian arms sellers and producers, Rosoboroneksport, Russia's main arms-selling agency, and Sukhoi, which manufactures aircraft, because of their arms sales to Iran...

  19. Changes in the bilateral pulse transit time difference with a moving arm.

    Science.gov (United States)

    Jiang, Xinge; Wei, Shoushui; Zheng, Dingchang; Huang, Peng; Liu, Chengyu

    2018-04-20

    Changes of pulse transit time (PTT) induced by arm position were studied for unilateral arm. However, consistency of the PTT changes was not validated for both arm sides. We aimed to quantify the PTT changes between horizontal and non-horizontal positions from right arm and left arm in order to explore the consistency of both arms. Twenty-four normal subjects aged between 21 and 50 (14 male and 10 female) years were enrolled. Left and right radial artery pulses were synchronously recorded from 24 healthy subjects with one arm (left or right) at five angles (90∘, 45∘, 0∘, -45∘ and -90∘) and the other arm at the horizontal level (0∘) for reference. The overall mean PTT changes at the five angles (from 90∘ to -90∘) in the left arm (right as reference) were 16.1, 12.3, -0.5, -2.5 and -2.6 ms, respectively, and in the right arm (left as reference) were 18.0, 12.6, 1.6, -1.6 and -2.0 ms, respectively. Obvious differences were not found in the PTT changes between the two arms (left arm moving or right arm moving) under each of the five different positions (all P> 0.05).

  20. The position of the arm during blood pressure measurement in sitting position.

    Science.gov (United States)

    Adiyaman, Ahmet; Verhoeff, Rutger; Lenders, Jacques W M; Deinum, Jaap; Thien, Theo

    2006-12-01

    Determining the influence of the position of the arm on blood pressure measurement in the sitting position. Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in two different positions. First, both arms were placed at the chair support level and blood pressure was measured three times on both arms after 10 min of rest. Subsequently, while still remaining in the same sitting position, five blood pressure measurements were made simultaneously at both arms with one arm placed on the desk and one arm placed and supported at heart level (mid-sternal). The arm placed at heart level served as the reference arm. The choice of which arm was placed at desk level and which arm was placed at heart level was randomized. Both at desk level and at chair support level, mean (+/-SD) systolic and diastolic blood pressures were higher than blood pressure at heart level by 6.1/5.7+/-4.6/3.1 and 9.3/9.4+/-5.4/3.4 mmHg, respectively. The effect of the height differences between the arm positions on the blood pressure readings was smaller than predicted (0.49 mmHg/cm systolic and 0.47 mmHg/cm diastolic). No significant correlation was found between blood pressure difference in the different arm positions (desk and heart level) and age, sex, weight or baseline blood pressure. Different arm positions below heart level have significant effects on blood pressure readings. The leading guidelines about arm position during blood pressure measurement are not in accordance with the arm position used in the Framingham study, the most frequently used study for risk estimations.

  1. Homosexuality in the Dutch Armed Forces 2006

    NARCIS (Netherlands)

    Anna Adolfsen; Saskia Keuzenkamp; m.m.v. Linda Mans

    2006-01-01

    Original title: Uniform uit de kast. This study looks at the attitudes of defence personnel to homosexuality. How do members of the military view homosexual colleagues? Can gays and lesbians working in the armed forces be open about their sexual preferences? Do they regard the armed forces as

  2. TOWARDS UNIFORM RULES FOR ARMED CONFLICTS Pieter ...

    African Journals Online (AJOL)

    the two Additional Protocols that followed in 1977, divide armed conflict into two legal categories: ... Wounded, Sick and Shipwrecked Members of Armed Forces at Sea. Third Convention ... Nationalist China; ibid 116. ... 17 Pictet op cit 43; Junod, S 'Additional Protocol II: History and Scope' (1983) 33 The. American ...

  3. Limited consensus around ARM information protection practices1

    African Journals Online (AJOL)

    KATUU, Shadrack

    surrounding Information Protection (IP) has been ... compares IP and ARM information protection through .... decision-making methodology used to help ... and differing requirements of institutions into account. ARM literature is prescriptive with.

  4. Nudging Armed Groups: How Civilians Transmit Norms of Protection

    Directory of Open Access Journals (Sweden)

    Oliver Kaplan

    2013-12-01

    Full Text Available What are the varying roles that norms play to either enable or constrain violence in armed conflict settings? The article examines this question by drawing on experiences from communities and armed groups in Colombia and Syria. It begins by presenting an explanation of how norms of violence and nonviolence may arise within communities and influence the behavior of civilian residents, reducing the chances of them becoming involved with armed groups. It then considers how civilian communities can transmit those same norms, shared understandings, and patterns of interaction to the ranks of illegal armed groups and subsequently shape their decisions about the use of violence against civilians. The author argues that civilians may be better positioned to promote the principles codified in International Humanitarian Law than international humanitarian organizations because they have closer contact with irregular armed actors and are viewed with greater legitimacy. The analysis illustrates that to better understand civilian protection mechanisms it is essential to study the interactions between communities and armed actors.

  5. Cryo-scanning electron microscopy investigation of the Octopus Vulgaris arm structures for the design of an octopus-like arm artefact.

    Science.gov (United States)

    Minnocci, Antonio; Cianchetti, Matteo; Mazzolai, Barbara; Sebastiani, Luca; Laschi, Cecilia

    2015-12-01

    Octopus vulgaris is a cephalopod of the Octopodidae family. It has four pairs of arms and two rows of suckers which perform many functions, including bending and elongation. For this reason the octopus was chosen as model to develop a new generation of soft-body robots. In order to explain some of the fine structures of the octopus arm in relation to its specific ability, we examined the external and internal structures of O. vulgaris arms in a frozen-hydrated state using cryo-scanning electron microscopy. The arms showed skin with a very complex design that is useful to elongation, and a pore pattern distribution on their surface which is functional to cutaneous oxygen uptake. The analysis of freeze-fractured frozen-hydrated arm samples allowed us to describe the developmental differences in the relative proportion of the areas of axial nerve cord, intrinsic and extrinsic musculature, in relation to the growth of the arms and of the increase in functional capability. In the suckers, we analyzed the shedding mechanisms in the outer part of the infundibulum and described the outer and inner characteristics of the denticles, showing in detail their pore system, which is fundamental for their ability to explore the environment. These results are discussed by considering their possible application in the design of new octopus-like artefacts, which will be able to take advantage of some of these ultrastructure characteristics and achieve advanced bioinspired functionalities. © 2015 Wiley Periodicals, Inc.

  6. Galaxy Zoo: constraining the origin of spiral arms

    Science.gov (United States)

    Hart, Ross E.; Bamford, Steven P.; Keel, William C.; Kruk, Sandor J.; Masters, Karen L.; Simmons, Brooke D.; Smethurst, Rebecca J.

    2018-05-01

    Since the discovery that the majority of low-redshift galaxies exhibit some level of spiral structure, a number of theories have been proposed as to why these patterns exist. A popular explanation is a process known as swing amplification, yet there is no observational evidence to prove that such a mechanism is at play. By using a number of measured properties of galaxies, and scaling relations where there are no direct measurements, we model samples of SDSS and S4G spiral galaxies in terms of their relative halo, bulge and disc mass and size. Using these models, we test predictions of swing amplification theory with respect to directly measured spiral arm numbers from Galaxy Zoo 2. We find that neither a universal cored or cuspy inner dark matter profile can correctly predict observed numbers of arms in galaxies. However, by invoking a halo contraction/expansion model, a clear bimodality in the spiral galaxy population emerges. Approximately 40 per cent of unbarred spiral galaxies at z ≲ 0.1 and M* ≳ 1010M⊙ have spiral arms that can be modelled by swing amplification. This population display a significant correlation between predicted and observed spiral arm numbers, evidence that they are swing amplified modes. The remainder are dominated by two-arm systems for which the model predicts significantly higher arm numbers. These are likely driven by tidal interactions or other mechanisms.

  7. Einrichtung zum Spannen eines Endlos-Transmissionselements

    OpenAIRE

    Boley, D.; Rhomberg Kauert, A.

    1995-01-01

    The description refers to a device for clamping an endless transmission element such as a belt, a toothed belt or a chain of a drive unit, comprising a roller which contacts the transmission element and which has a rocker bearing which is applied against a spring in the direction of the transmission element. The invention is characterized by the fact that a blocking unit is provided to prevent the rocker from performing a return stroke.

  8. Grand-design Spiral Arms in a Young Forming Circumstellar Disk

    Energy Technology Data Exchange (ETDEWEB)

    Tomida, Kengo; Lin, Chia Hui [Department of Earth and Space Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Machida, Masahiro N. [Department of Earth and Planetary Sciences, Faculty of Sciences, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan); Hosokawa, Takashi [Department of Physics, Kyoto University, Sakyo-ku, Kyoto 606-8502 (Japan); Sakurai, Yuya, E-mail: tomida@vega.ess.sci.osaka-u.ac.jp [Department of Physics, The University of Tokyo, Tokyo 113-0033 (Japan)

    2017-01-20

    We study formation and long-term evolution of a circumstellar disk in a collapsing molecular cloud core using a resistive magnetohydrodynamic simulation. While the formed circumstellar disk is initially small, it grows as accretion continues, and its radius becomes as large as 200 au toward the end of the Class-I phase. A pair of grand-design spiral arms form due to gravitational instability in the disk, and they transfer angular momentum in the highly resistive disk. Although the spiral arms disappear in a few rotations as expected in a classical theory, new spiral arms form recurrently as the disk, soon becoming unstable again by gas accretion. Such recurrent spiral arms persist throughout the Class-0 and I phases. We then perform synthetic observations and compare our model with a recent high-resolution observation of a young stellar object Elias 2–27, whose circumstellar disk has grand-design spiral arms. We find good agreement between our theoretical model and the observation. Our model suggests that the grand-design spiral arms around Elias 2–27 are consistent with material arms formed by gravitational instability. If such spiral arms commonly exist in young circumstellar disks, it implies that young circumstellar disks are considerably massive and gravitational instability is the key process of angular momentum transport.

  9. Grand-design Spiral Arms in a Young Forming Circumstellar Disk

    International Nuclear Information System (INIS)

    Tomida, Kengo; Lin, Chia Hui; Machida, Masahiro N.; Hosokawa, Takashi; Sakurai, Yuya

    2017-01-01

    We study formation and long-term evolution of a circumstellar disk in a collapsing molecular cloud core using a resistive magnetohydrodynamic simulation. While the formed circumstellar disk is initially small, it grows as accretion continues, and its radius becomes as large as 200 au toward the end of the Class-I phase. A pair of grand-design spiral arms form due to gravitational instability in the disk, and they transfer angular momentum in the highly resistive disk. Although the spiral arms disappear in a few rotations as expected in a classical theory, new spiral arms form recurrently as the disk, soon becoming unstable again by gas accretion. Such recurrent spiral arms persist throughout the Class-0 and I phases. We then perform synthetic observations and compare our model with a recent high-resolution observation of a young stellar object Elias 2–27, whose circumstellar disk has grand-design spiral arms. We find good agreement between our theoretical model and the observation. Our model suggests that the grand-design spiral arms around Elias 2–27 are consistent with material arms formed by gravitational instability. If such spiral arms commonly exist in young circumstellar disks, it implies that young circumstellar disks are considerably massive and gravitational instability is the key process of angular momentum transport.

  10. The globalization of the arms industry: The next proliferation challenge

    Energy Technology Data Exchange (ETDEWEB)

    Bitzinger, R.A.

    1994-12-31

    The globalization of the arms industry entails a significant shift away from traditional, single-country patterns of weapons production toward internationalization of the development, production, and marketing of arms. While wholly indigenous armaments production may be on the decline, multinational arms production - through collaboration on individual weapon systems and increasingly via interfirm linkages across the international arms industry - appears actually to be expanding. In several instances, in fact, multinational armaments production is increasingly supplementing or even supplanting indigenous or autonomous weapons production or arms imports. The emergence of an increasingly transnational defense technology and industrial base is fundamentally affecting the shape and content of much of the global arms trade. This changing defense market, in turn, will have a profound impact on a number of national security issues concerning the Western industrialized nations. 3 figs., 2 tabs.

  11. Development of the OPESCOPE mobile C-arm system

    International Nuclear Information System (INIS)

    Tsuji, Hisao; Kadowaki, Toshio; Shimizu, Yasumitsu

    1994-01-01

    A new mobile C-arm X-ray fluoroscopy system called the 'OPESCOPE' equipped with a CCD TV camera and high-definition Image Intensifier has been developed. All the cables for the I.I. and X-ray generator are held inside the C-arm to prevent interference with operation and the C-arm is locked electromagnetically. Moreover, the C-arm is spring counterbalanced in the vertical motion axis. These features enable smooth positioning and uncluttered operation. The X-ray generator uses a high-frequency inverter designed to assure noiseless operation and a compact size. With the new DFS-700 videoprocessor unit being combined, clearer, more informative images can be obtained. In addition to its inherent portability this unit can be upgraded in DSA function to allow angiographic examinations in the surgical theater. (author)

  12. Inter-arm blood pressure differences in young, healthy patients.

    Science.gov (United States)

    Grossman, Alon; Prokupetz, Alex; Gordon, Barak; Morag-Koren, Nira; Grossman, Ehud

    2013-08-01

    The prevalence and magnitude of inter-arm BP difference (IAD) in young healthy patients is not well characterized. Flight academy applicants and designated aviators undergo annual evaluation that includes blood pressure (BP) measurement on both arms. All BP measurements performed from January 1, 2012, to April 30, 2012, were recorded and IAD was calculated. Results were compared between patients in whom BP was initially measured in the right arm (group 1), those in whom BP was initially measured in the left arm (group 2), and those in whom the arm in which BP was initially measured was not recorded (group 3). A total of 877 healthy patients had BP measured during the study period. In the entire group, mean systolic BP was the same in both arms. Absolute IAD was 5.6±5.5 mm Hg for systolic and 4.7±4.5 mm Hg for diastolic BP. IAD >10 mm Hg was recorded in 111 (12.6%) and 77 (8.8%) patients for systolic and diastolic BP, respectively. IAD was the same in the 3 groups and was unrelated to age, body mass index, and heart rate, but was related to systolic BP. IAD is common in young healthy patients, is not dependent on which arm was measured first, and unrelated to age, body mass index, and heart rate. © 2013 Wiley Periodicals, Inc.

  13. Trigonometric parallaxes of star forming regions in the Scutum spiral arm

    International Nuclear Information System (INIS)

    Sato, M.; Wu, Y. W.; Immer, K.; Zhang, B.; Sanna, A.; Brunthaler, A.; Menten, K. M.; Reid, M. J.; Dame, T. M.

    2014-01-01

    We report measurements of trigonometric parallaxes for six high-mass star-forming regions in the Scutum spiral arm of the Milky Way as part of the BeSSeL Survey. Combining our measurements with 10 previous measurements from the BeSSeL Survey yields a total sample of 16 sources in the Scutum arm with trigonometric parallaxes in the Galactic longitude range from 5° to 32°. Assuming a logarithmic spiral model, we estimate a pitch angle of 19.°8 ± 3.°1 for the Scutum arm, which is larger than pitch angles reported for other spiral arms. The high pitch angle of the arm may be due to the arm's proximity to the Galactic bar. The Scutum arm sources show an average peculiar motion of 4 km s –1 slower than the Galactic rotation and 8 km s –1 toward the Galactic center. While the direction of this non-circular motion has the same sign as determined for sources in other spiral arms, the motion toward the Galactic center is greater for the Scutum arm sources.

  14. CATALOG OF OBSERVED TANGENTS TO THE SPIRAL ARMS IN THE MILKY WAY GALAXY

    Energy Technology Data Exchange (ETDEWEB)

    Vallée, Jacques P., E-mail: jacques.vallee@nrc-cnrc.gc.ca [Herzberg Astrophysics, National Research Council Canada, National Science Infrastructure portfolio, 5071 West Saanich Road, Victoria, BC, V9E 2E7 (Canada)

    2014-11-01

    From the Sun's location in the Galactic disk, one can use different arm tracers (CO, H I, thermal or ionized or relativistic electrons, masers, cold and hot dust, etc.) to locate a tangent to each spiral arm in the disk of the Milky Way. We present a master catalog of the astronomically observed tangents to the Galaxy's spiral arms, using different arm tracers from the literature. Some arm tracers can have slightly divergent results from several papers, so a mean value is taken—see the Appendix for CO, H II, and masers. The catalog of means currently consists of 63 mean tracer entries, spread over many arms (Carina, Crux-Centaurus, Norma, Perseus origin, near 3 kpc, Scutum, Sagittarius), stemming from 107 original arm tracer entries. Additionally, we updated and revised a previous statistical analysis of the angular offset and linear separation from the mid-arm for each different mean arm tracer. Given enough arm tracers, and summing and averaging over all four spiral arms, one could determine if arm tracers have separate and parallel lanes in the Milky Way. This statistical analysis allows a cross-cut of a Galactic spiral arm to be made, confirming a recent discovery of a linear separation between arm tracers. Here, from the mid-arm's CO to the inner edge's hot dust, the arm halfwidth is about 340 pc; doubling would yield a full arm width of 680 pc. We briefly compare these observations with the predictions of many spiral arm theories, notably the density wave theory.

  15. CATALOG OF OBSERVED TANGENTS TO THE SPIRAL ARMS IN THE MILKY WAY GALAXY

    International Nuclear Information System (INIS)

    Vallée, Jacques P.

    2014-01-01

    From the Sun's location in the Galactic disk, one can use different arm tracers (CO, H I, thermal or ionized or relativistic electrons, masers, cold and hot dust, etc.) to locate a tangent to each spiral arm in the disk of the Milky Way. We present a master catalog of the astronomically observed tangents to the Galaxy's spiral arms, using different arm tracers from the literature. Some arm tracers can have slightly divergent results from several papers, so a mean value is taken—see the Appendix for CO, H II, and masers. The catalog of means currently consists of 63 mean tracer entries, spread over many arms (Carina, Crux-Centaurus, Norma, Perseus origin, near 3 kpc, Scutum, Sagittarius), stemming from 107 original arm tracer entries. Additionally, we updated and revised a previous statistical analysis of the angular offset and linear separation from the mid-arm for each different mean arm tracer. Given enough arm tracers, and summing and averaging over all four spiral arms, one could determine if arm tracers have separate and parallel lanes in the Milky Way. This statistical analysis allows a cross-cut of a Galactic spiral arm to be made, confirming a recent discovery of a linear separation between arm tracers. Here, from the mid-arm's CO to the inner edge's hot dust, the arm halfwidth is about 340 pc; doubling would yield a full arm width of 680 pc. We briefly compare these observations with the predictions of many spiral arm theories, notably the density wave theory

  16. Neck and arm pain syndromes

    DEFF Research Database (Denmark)

    de las Peñas, César Fernández; Cleland, Joshua; Huijbregts, Peter

    approaches.It uniquely addresses the expanding role of the various health care professions which require increased knowledge and skills in screening for contra-indications and recognizing the need for medical-surgical referral. Neck and Arm Pain Syndromes also stresses the integration of experiential......The first of its kind, Neck and Arm Pain Syndromes is a comprehensive evidence- and clinical-based book, covering research-based diagnosis, prognosis and management of neuromusculoskeletal pathologies and dysfunctions of the upper quadrant, including joint, muscle, myofascial and neural tissue...... of the most commonly seen pain syndromes in clinical practice over 800 illustrations demonstrating examination procedures and techniques....

  17. Structure of the S6 spirel arm in the Andromeda galaxy

    International Nuclear Information System (INIS)

    Efremov, Yu.N.

    1982-01-01

    The distribution of stars across the spiral arm S6 in M 31 within Baade's Field 4 is investigated. It is found that the brightest stars are concentrated to the middle line of the arm where the maximal star density is also observed. The symmetry of the arm S6 may be explained by its position near the corotation radius that followed from the spiral pattern velocity Ωsub(P) approximately 10 km/s kpc determined by the age gradient in the arm S4. The similarity between the structure of the arm S6 and that of the spiral arms near the Sun is pointed out [ru

  18. Current Sharing Analysis of Arm Prototype for ITER PF Converter Bridge

    International Nuclear Information System (INIS)

    Li Jinchao; Song Zhiquan; Xu Liuwei; Fu Peng; Guo Bin; Li Sen; Dong Lin; Wang Min

    2014-01-01

    A bridge arm prototype of ITER poloidal field (PF) converter modules has been designed and fabricated. Non-cophase counter parallel connection is chosen as the arm structure of the prototype. Among all factors affecting current sharing, arm structure is the main one. During the design of the arm prototype, a novel method based on inductance matrixes is employed to improve the current sharing of the bridge arm. The test results on the prototype show that the current sharing performance of the arm prototype is much better than relevant design requirement, and that the matrix method is very effective to analyze and solve the current sharing problems of thyristor converters

  19. Adaptation of the Pivotal-Differential Genome Pattern for the Induction of Intergenomic Chromosome Recombination in Hybrids of Synthetic Amphidiploids within Triticeae Tribe

    Directory of Open Access Journals (Sweden)

    Michal T. Kwiatek

    2017-07-01

    Full Text Available A pivotal-differential evolution pattern is when two allopolyploids share a common genome, which is called pivotal, and differ with respect to the other genome or genomes, called differential. This feature induces the intergenomic recombination between chromosomes of differential genomes, which can lead to speciation. Our study is a cytomolecular insight into this mechanism which was adapted for the induction of intergenomic chromosome recombination in hybrids of synthetic amphidiploids Aegilops biuncialis × S. cereale (UUMMRR and triticale (AABBRR where R-genome was pivotal. We observed chromosome recombination events which were induced by both: (1 random chromosome fragmentation and non-homologous chromosome end joining at mitosis of root meristem cells and (2 intergenomic chromosome associations at meiosis of pollen mother cells (PMCs of F1 hybrids. Reciprocal chromosome translocations were identified in six F1 plants and 15 plants of F2 generation using fluorescence in situ hybridization (FISH with DNA clones (pTa-86, pTa-k374, pTa-465, pTa-535, pTa-k566, and pTa-713. We observed signals of pTa-86, pTa-535, and pTa-k566 probes in several chromosome breakpoints. The comparison of the DNA clone sequences distinguished a number of common motifs, which can be considered as characteristics of chromosome breakpoint loci. Immunodetection of synaptonemal complex proteins and genomic in situ hybridization analysis at meiosis of PMCs of F1 hybrids showed, that the homologous pairing of pivotal R—genome chromosomes is crucial for the fertility of F1 hybrids, however, these chromosomes can be also involved in the intergeneric recombination.

  20. CHARACTERIZING SPIRAL ARM AND INTERARM STAR FORMATION

    Energy Technology Data Exchange (ETDEWEB)

    Kreckel, K.; Schinnerer, E.; Meidt, S. [Max Planck Institut für Astronomie, Königstuhl 17, D-69117 Heidelberg (Germany); Blanc, G. A. [Departamento de Astronomía, Universidad de Chile, Camino del Observatorio 1515, Las Condes, Santiago (Chile); Groves, B. [Research School of Astronomy and Astrophysics, Australian National University, Canberra, ACT 2611 (Australia); Adamo, A. [Department of Astronomy, The Oskar Klein Centre, Stockholm University, AlbaNova University Centre, SE-106 91 Stockholm (Sweden); Hughes, A., E-mail: kreckel@mpia.de [CNRS, IRAP, 9 Av. du Colonel Roche, BP 44346, F-31028 Toulouse cedex 4 (France)

    2016-08-20

    Interarm star formation contributes significantly to a galaxy’s star formation budget and provides an opportunity to study stellar birthplaces unperturbed by spiral arm dynamics. Using optical integral field spectroscopy of the nearby galaxy NGC 628 with VLT/MUSE, we construct H α maps including detailed corrections for dust extinction and stellar absorption to identify 391 H ii regions at 35 pc resolution over 12 kpc{sup 2}. Using tracers sensitive to the underlying gravitational potential, we associate H ii regions with either arm (271) or interarm (120) environments. Using our full spectral coverage of each region, we find that most physical properties (luminosity, size, metallicity, ionization parameter) of H ii regions are independent of environment. We calculate the fraction of H α luminosity due to the background of diffuse ionized gas (DIG) contaminating each H ii region, and find the DIG surface brightness to be higher within H ii regions than in the surroundings, and slightly higher within arm H ii regions. Use of the temperature-sensitive [S ii]/H α line ratio instead of the H α surface brightness to identify the boundaries of H ii regions does not change this result. Using the dust attenuation as a tracer of the gas, we find depletion times consistent with previous work (2 × 10{sup 9} yr) with no differences between the arm and interarm, but this is very sensitive to the DIG correction. Unlike molecular clouds, which can be dynamically affected by the galactic environment, we see fairly consistent properties of H ii regions in both arm and interarm environments. This suggests either a difference in star formation and feedback in arms or a decoupling of dense star-forming clumps from the more extended surrounding molecular gas.

  1. Effect of arm swing strategy on local dynamic stability of human gait.

    Science.gov (United States)

    Punt, Michiel; Bruijn, Sjoerd M; Wittink, Harriet; van Dieën, Jaap H

    2015-02-01

    Falling causes long term disability and can even lead to death. Most falls occur during gait. Therefore improving gait stability might be beneficial for people at risk of falling. Recently arm swing has been shown to influence gait stability. However at present it remains unknown which mode of arm swing creates the most stable gait. To examine how different modes of arm swing affect gait stability. Ten healthy young male subjects volunteered for this study. All subjects walked with four different arm swing instructions at seven different gait speeds. The Xsens motion capture suit was used to capture gait kinematics. Basic gait parameters, variability and stability measures were calculated. We found an increased stability in the medio-lateral direction with excessive arm swing in comparison to normal arm swing at all gait speeds. Moreover, excessive arm swing increased stability in the anterior-posterior and vertical direction at low gait speeds. Ipsilateral and inphase arm swing did not differ compared to a normal arm swing. Excessive arm swing is a promising gait manipulation to improve local dynamic stability. For excessive arm swing in the ML direction there appears to be converging evidence. The effect of excessive arm swing on more clinically relevant groups like the more fall prone elderly or stroke survivors is worth further investigating. Excessive arm swing significantly increases local dynamic stability of human gait. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. The European Union and armed drones: framing the debate

    DEFF Research Database (Denmark)

    Martins, Bruno Oliveira

    2015-01-01

    Armed drones are an issue extremely relevant for the EU. The recent emergence of targeted killings as a common counter-terrorism technique, the existence of several EU member states using armed and surveillance drones in military scenarios, the presence of member states troops in areas where armed...... drones have been active, the US use of European-originated intelligence to execute targeted killings, and the broader status of international law, are developments that illustrate the importance of the topic. Yet, the EU still does not have an official position on armed drones. In 2014 the European...... Parliament recognized that this is problematic, adopting a Resolution that expressed “grave concern over the use of armed drones outside the international legal framework” and that urged the EU to “develop an appropriate policy response at both European and global level”. This Forum answers to the European...

  3. Fractures of the humerus during arm wrestling

    Directory of Open Access Journals (Sweden)

    Bumbaširević Marko Ž.

    2014-01-01

    Full Text Available Background/Aim. Humeral shaft fractures may occur as a result of arm wrestling. The aim of this study was to present our treatment of humerus fracture sustained during arm wrestling. Methods. A total of six patients, aged 22 to 48, were treated at our department form January 2008 to January 2010 with open reduction and internal fixation and with hanging arm casts. A review of all the relevant literature on the subject was also presented. Results. In all the cases, the fractures healed and function returned to normal. No patient had any neural or vascular compromise. Conclusion. Closed and operative treatments were equally successful in all reported cases. [Projekat Ministarstva nauke Republike Srbije, br. 175-095

  4. ARM Climate Research Facility Annual Report 2005

    Energy Technology Data Exchange (ETDEWEB)

    J. Voyles

    2005-12-31

    Through the ARM Program, the DOE funded the development of several highly instrumented ground stations for studying cloud formation processes and their influence on radiative transfer, and for measuring other parameters that determine the radiative properties of the atmosphere. This scientific infrastructure, and resultant data archive, is a valuable national and international asset for advancing scientific knowledge of Earth systems. In fiscal year (FY) 2003, the DOE designated ARM sites as a national scientific user facility: the ARM Climate Research (ACRF). The ACRF has enormous potential to contribute to a wide range interdisciplinary science in areas such as meteorology, atmospheric aerosols, hydrology, biogeochemical cycling, and satellite validation, to name only a few.

  5. Arms Trafficking and Colombia

    National Research Council Canada - National Science Library

    Cragin, Kim; Hoffman, Bruce

    2003-01-01

    ... to traditional definitions of a security threat. For this analysis, the term "small arms" refers to man-portable personal and military weapons, ranging from handguns to assault rifles to surface-to-air missiles (SAMs...

  6. EEG Mind Controlled Smart Prosthetic Arm – A Comprehensive Study

    Directory of Open Access Journals (Sweden)

    Taha Beyrouthy

    2017-06-01

    Full Text Available Recently, the field of prosthetics has seen many accomplishments especially with the integration of technological advancements. In this paper, different arm types (robotic, surgical, bionic, prosthetic and static are analyzed in terms of resistance, usage, flexibility, cost and potential. Most of these techniques have some problems; they are extremely expensive, hard to install and maintain and may require surgery. Therefore, our work introduces the initial design of an EEG mind controlled smart prosthetic arm. The arm is controlled by the brain commands, obtained from an electroencephalography (EEG headset, and equipped with a network of smart sensors and actuators that give the patient intelligent feedback about the surrounding environment and the object in contact. This network provides the arm with normal hand functionality, smart reflexes and smooth movements. Various types of sensors are used including temperature, pressure, ultrasonic proximity sensors, accelerometers, potentiometers, strain gauges and gyroscopes. The arm is completely 3D printed built from various lightweight and high strength materials that can handle high impacts and fragile elements as well. Our project requires the use of nine servomotors installed at different places in the arm. Therefore, the static and dynamic modes of servomotors are analyzed. The total cost of the project is estimated to be relatively cheap compared to other previously built arms. Many scenarios are analyzed corresponding to the actions that the prosthetic arm can perform, and an algorithm is created to match these scenarios. Experimental results show that the proposed EEG Mind-controlled Arm is a promising alternative for current solutions that require invasive and expensive surgical procedures.

  7. The metabolic cost of human running: is swinging the arms worth it?

    Science.gov (United States)

    Arellano, Christopher J; Kram, Rodger

    2014-07-15

    Although the mechanical function is quite clear, there is no consensus regarding the metabolic benefit of arm swing during human running. We compared the metabolic cost of running using normal arm swing with the metabolic cost of running while restricting the arms in three different ways: (1) holding the hands with the arms behind the back in a relaxed position (BACK), (2) holding the arms across the chest (CHEST) and (3) holding the hands on top of the head (HEAD). We hypothesized that running without arm swing would demand a greater metabolic cost than running with arm swing. Indeed, when compared with running using normal arm swing, we found that net metabolic power demand was 3, 9 and 13% greater for the BACK, CHEST and HEAD conditions, respectively (all Prunning without arm swing, subjects significantly increased the peak-to-peak amplitudes of both shoulder and pelvis rotation about the vertical axis, most likely a compensatory strategy to counterbalance the rotational angular momentum of the swinging legs. In conclusion, our findings support our general hypothesis that swinging the arms reduces the metabolic cost of human running. Our findings also demonstrate that arm swing minimizes torso rotation. We infer that actively swinging the arms provides both metabolic and biomechanical benefits during human running. © 2014. Published by The Company of Biologists Ltd.

  8. A Unified Approach for Reporting ARM Measurement Uncertainties Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Campos, E [Argonne National Laboratory; Sisterson, DL [Argonne National Laboratory

    2015-10-01

    The Atmospheric Radiation Measurement (ARM) Climate Research Facility is observationally based, and quantifying the uncertainty of its measurements is critically important. With over 300 widely differing instruments providing over 2,500 datastreams, concise expression of measurement uncertainty is quite challenging. The ARM Facility currently provides data and supporting metadata (information about the data or data quality) to its users through a number of sources. Because the continued success of the ARM Facility depends on the known quality of its measurements, the Facility relies on instrument mentors and the ARM Data Quality Office (DQO) to ensure, assess, and report measurement quality. Therefore, an easily-accessible, well-articulated estimate of ARM measurement uncertainty is needed.

  9. Participation in Armed Forces, National, and International Sports Activities

    Science.gov (United States)

    1987-03-09

    American Games , Olympic Games , and other authorized national and international sports competitions (to include qualifying and preparatory events) as long...concerning the participation of Armed Forces personnel in Armed Forces, national, and international sports competitions ; establishes a Senior Military Sports ...program is to ensure that the U.S. Armed Forces are appropriately represented in national and international sports competitions . 3. The purpose of this

  10. The effect of arm sling on balance in patients with hemiplegia.

    Science.gov (United States)

    Acar, Merve; Karatas, Gulcin Kaymak

    2010-10-01

    The aim of this study was to investigate the effect of an arm sling on balance in patients with, hemiplegia following a stroke. Twenty-six patients with hemiplegia (11 men, 15 women) who had, shoulder subluxation were enrolled in the study. Balance was evaluated by the Berg Balance Scale, the, Functional Reach test, and a static balance index which was measured by the Kinesthetic Ability, Trainer 3000. Balance tests were performed twice, with arm sling and without arm sling use. Results of, this study show that the Berg Balance Scores and static balance index ameliorated with arm sling use (p=0.005 and p=0.004, respectively). Likewise, the Functional Reach test was better when performed with an arm sling (p=0.039). In conclusion, arm slings have a beneficial effect on balance in patients, with hemiplegia. An arm sling may be applied for its possible beneficial effect on balance especially in, the early phases of stroke rehabilitation while the upper extremity is still flaccid and arm swing is, reduced. Copyright © 2010 Elsevier B.V. All rights reserved.

  11. Spiral arms, comets and terrestrial catastrophism

    International Nuclear Information System (INIS)

    Clube, S.V.M.; Napier, W.M.

    1982-01-01

    A review is presented of an hypothesis of terrestrial catastrophism in which comets grow in molecular clouds and are captured by the Sun as it passes through the spiral arms of the Galaxy. Assuming that comets are a major supplier of the Earth-crossing (Appollo) asteroid population, the latter fluctuates correspondingly and leads to episodes of terrestrial bombardment. Changes in the rotational momentum of core and mantle, generated by impacts, lead to episodes of magnetic field reversal and tectonic activity, while surface phenomena lead to ice-ages and mass extinctions. An episodic geophysical history with an interstellar connection is thus implied. If comets in spiral arms are necessary intermediaries in the process of star formation, the theory also has implications relating to early solar system history and galactic chemistry. These aspects are briefly discussed with special reference to the nature of spiral arms. (author)

  12. Stress analysis for robot arm version 2

    International Nuclear Information System (INIS)

    Anwar Abdul Rahman; Fikri, A.; Salleh, M. S.; Mohd Arif Hamzah; Azraf Azman; Rosli Darmawan; Mohd Rizal Mamat

    2010-01-01

    The design of a robot needs to be analyzed to ensure the specification and requirement by the user is full filled. Therefore, stress analysis has been performed on the robot arm version 2 after its complete fabrication. This paper discusses the result of the analysis and proposed measures to improve the future design of robot arm. (author)

  13. C-arm CT for chemo-embolization of liver tumors

    International Nuclear Information System (INIS)

    Huppert, P.E.; Firlbeck, G.; Meissner, O.A.; Wietholtz, H.

    2009-01-01

    Local efficacy of transarterial chemo-embolization (TACE) is enhanced if selective treatment is performed. Selectivity of TACE mainly depends on vascular anatomy but also on the identification and catheterization of tumor feeding arteries. Correlation of vascular territories and target tumor volume in angiographic projection images is more difficult if tumors are not hypervascularized and contrast of liver parenchyma is inhomogeneous. C-arm CT offers the option of selective perfusion imaging via tumor-feeding arteries. This allows the comparison of perfusion images and baseline cross-sectional imaging to evaluate if tumors are covered completely by local treatment and to change the catheter position if necessary. Furthermore the uptake of embolization material, such as lipiodol can be checked by C-arm CT. In a prospective study of 75 TACE of liver tumors and liver metastases we evaluated the appropriateness of 85 catheter positions ready for delivery by perfusion C-arm CT and compared the diagnostic confidence of angiography and perfusion C-arm CT in terms of judgment of correct catheter position for the planned treatment. Diagnostic confidence was improved by perfusion C-arm CT in 55% of cases and in 11 cases (13%) catheter positions were inappropriate and had to be corrected. The reasons for catheter repositioning were incomplete coverage of the target tumor by perfusion volume (mismatch) in 6 cases, inappropriate perfusion of adjacent liver parenchyma in 2 cases and non-selective tumor perfusion via collateral arteries in 3 cases. C-arm CT allowed sufficient visualization of uptake of lipiodol in all cases evaluated. The diagnostic benefit of C-arm CT increases if tumors are treated more selectively, are not strongly hypervascular, are located centrally and if the enhancement of liver parenchyma is inhomogeneous. C-arm CT causes additional working time and contrast load, which is relatively low compared to angiography. Radiation exposure of 151 μGy per C-arm

  14. Design and analysis on robotic arm for serving hazard container

    Science.gov (United States)

    Razali, Zol Bahri; Kader, Mohamed Mydin M. Abdul; Yi, Khoo Zern; Daud, Mohd Hisam

    2017-09-01

    This paper presents about design, analyses development and fabrication of robotic arm for sorting multi-material. The major problem that urges the initiation of the project is the fact that manufacturing industry is growing at relatively faster rate. Most of the company produce high load robotic arm. Less company creates light weight, and affordable robotic arm. As the result, light weight and affordable robot is developing to cover this issue. Plastic material was used to construct the body of the robotic arm, and an optical sensor was implemented to provide basic recognition of object to be carried. The robotic arm used five servomotors for overall operation; four for its joints, and one for the gripping mechanism. The gripper was designed and fabricated using Perspex due to the light weight and high strength of the material. The operation of the robotic arm was governed by Basic Stamp programming sequence and the device was expected to differentiate material and other objects based on reflective theory, and perform subsequent operations afterwards. The SolidWorks was used to model the detail design of the robotic arm, and to simulate the motion of the device.

  15. The Influences of Arm Resist Motion on a CAR Crash Test Using Hybrid III Dummy with Human-Like Arm

    Science.gov (United States)

    Kim, Yongchul; Youm, Youngil; Bae, Hanil; Choi, Hyeonki

    Safety of the occupant during the crash is very essential design element. Many researches have been investigated in reducing the fatal injury of occupant. They are focusing on the development of a dummy in order to obtain the real human-like motion. However, they have not considered the arm resist motion during the car accident. In this study, we would like to suggest the importance of the reactive force of the arm in a car crash. The influences of reactive force acting on the human upper extremity were investigated using the impedance experimental method with lumped mass model of hand system and a Hybrid III dummy with human-like arm. Impedance parameters (e.g. inertia, spring constant and damping coefficient) of the elbow joint in maximum activation level were measured by free oscillation test using single axis robot. The results showed that without seat belt, the reactive force of human arm reduced the head, chest, and femur injury, and the flexion moment of the neck is higher than that of the conventional dummy.

  16. AN OUTER ARM IN THE SECOND GALACTIC QUADRANT: STRUCTURE

    Energy Technology Data Exchange (ETDEWEB)

    Du, Xinyu; Xu, Ye; Yang, Ji; Sun, Yan; Li, Facheng; Zhang, Shaobo; Zhou, Xin, E-mail: xydu@pmo.ac.cn, E-mail: xuye@pmo.ac.cn [Purple Mountain Observatory, Chinese Academy of Science, Nanjing 210008 (China)

    2016-05-01

    The lack of arm tracers, especially remote tracers, is one of the most difficult problems preventing us from studying the structure of the Milky Way. Fortunately, with its high-sensitivity CO survey, the Milky Way Imaging Scroll Painting (MWISP) project offers such an opportunity. Since completing about one-third of its mission, an area of l = [100, 150]°, b = [−3, 5]° has nearly been covered. The Outer arm of the Milky Way first clearly revealed its shape in the second galactic quadrant in the form of molecular gas—this is the first time that the Outer arm has been reported in such a large-scale mapping of molecular gas. Using the 115 GHz {sup 12}CO(1–0) data of MWISP at the LSR velocity ≃[−100, −60] km s{sup −1} and in the area mentioned above, we have detected 481 molecular clouds in total, and among them 332 (about 69%) are newly detected and 457 probably belong to the Outer arm. The total mass of the detected Outer arm clouds is ∼3.1 × 10{sup 6} M {sub ⊙}. Assuming that the spiral arm is a logarithmic spiral, the pitch angle is fitted as ∼13.°1. Besides combining both the CO data from MWISP and the 21 cm H i data from the Canadian Galactic Plane Survey (CGPS), the gas distribution, warp, and thickness of the Outer arm are also studied.

  17. Thigh muscle activity, knee motion, and impact force during side-step pivoting in agility-trained female basketball players.

    Science.gov (United States)

    Wilderman, Danielle R; Ross, Scott E; Padua, Darin A

    2009-01-01

    Improving neuromuscular control of hamstrings muscles might have implications for decreasing anterior cruciate ligament injuries in females. To examine the effects of a 6-week agility training program on quadriceps and hamstrings muscle activation, knee flexion angles, and peak vertical ground reaction force. Prospective, randomized clinical research trial. Sports medicine research laboratory. Thirty female intramural basketball players with no history of knee injury (age = 21.07 +/- 2.82 years, height = 171.27 +/- 4.66 cm, mass = 66.36 +/- 7.41 kg). Participants were assigned to an agility training group or a control group that did not participate in agility training. Participants in the agility training group trained 4 times per week for 6 weeks. We used surface electromyography to assess muscle activation for the rectus femoris, vastus medialis oblique, medial hamstrings, and lateral hamstrings for 50 milliseconds before initial ground contact and while the foot was in contact with the ground during a side-step pivot maneuver. Knee flexion angles (at initial ground contact, maximum knee flexion, knee flexion displacement) and peak vertical ground reaction force also were assessed during this maneuver. Participants in the training group increased medial hamstrings activation during ground contact after the 6-week agility training program. Both groups decreased their vastus medialis oblique muscle activation during ground contact. Knee flexion angles and peak vertical ground reaction force did not change for either group. Agility training improved medial hamstrings activity in female intramural basketball players during a side-step pivot maneuver. Agility training that improves hamstrings activity might have implications for reducing anterior cruciate ligament sprain injury associated with side-step pivots.

  18. Armed guards on vessels : insurance and liability

    Directory of Open Access Journals (Sweden)

    Mišo Mudrić

    2011-12-01

    Full Text Available The Paper examines the insurance and liability issues resulting from the use of armed guards on board vessels. The study begins with an overview of the available data on key economic fi gures representing the projected overall annual costs of modern piracy. The focus is then shifted to the issue of public versus private security, where possible dangers of private-based security options are discussed in general. After explaining why the Somalia region deserves a closer attention when compared to other pirate-infested waters, a brief summary of the international effort to combat piracy threat is presented, followed by a structured overview of the use of private maritime security options in the maritime sector in general. One security option is the use of armed guards on board vessels. This option is explored both from the political (the acceptance by stakeholders and legal standpoint (legal issues arising from the use of armed guards. An important remedy for the shipping companies/ operators threatened by the piracy hazard is the existence of affordable and effective (specialized marine insurance. A study of available piracy insurance policies is presented, followed by an analysis of case law and other legal issues arising from piracy attacks, which could prove important when considering the legal implications of armed guards employment. Finally, a simplifi ed economic analysis of available security options is presented, followed by the final assessment of benefi ts derived from the use of armed guards.

  19. Analyst Tools and Quality Control Software for the ARM Data System

    Energy Technology Data Exchange (ETDEWEB)

    Moore, S.T.

    2004-12-14

    ATK Mission Research develops analyst tools and automated quality control software in order to assist the Atmospheric Radiation Measurement (ARM) Data Quality Office with their data inspection tasks. We have developed a web-based data analysis and visualization tool, called NCVweb, that allows for easy viewing of ARM NetCDF files. NCVweb, along with our library of sharable Interactive Data Language procedures and functions, allows even novice ARM researchers to be productive with ARM data with only minimal effort. We also contribute to the ARM Data Quality Office by analyzing ARM data streams, developing new quality control metrics, new diagnostic plots, and integrating this information into DQ HandS - the Data Quality Health and Status web-based explorer. We have developed several ways to detect outliers in ARM data streams and have written software to run in an automated fashion to flag these outliers.

  20. Vorrichtung nach Art eines Knickarmroboters

    OpenAIRE

    Wanner, Martin Christoph; Dryba, Steffen; Wollenberg, Michael; Kny, Reinhart

    2015-01-01

    The invention relates to an articulated arm robot-type device for handling a payload, comprising a robot arm (R), which is attached to a base (1) that can be rotated about a first axis (A1), and at least two arm elements (2, 3), which are arranged one behind the other in the form of a kinematic chain and a first arm element (2) of which is mounted on the base (1) in a pivotal manner about a second axis (A2) that is oriented orthogonally relative to the first axis and a second arm element (3) ...

  1. Prevalence of inter-arm blood pressure difference among clinical out-patients.

    Science.gov (United States)

    Sharma, Balkishan; Ramawat, Pramila

    2016-04-01

    An increased inter-arm blood pressure difference is an easily determined physical finding, may use as an indicator of cardio vascular event and other sever diseases. Authors evaluated 477 patients to determine the prevalence and significance of inter-arm blood pressure difference. 477 routine outdoor patients selected to observe the inter-arm blood pressure difference. Age, height, weight, body mass index, history of disease and blood pressure recorded. The prevalence of ≥10 mmHg systolic inter-arm blood pressure difference was 5.0% was more as compared to 3.8% had diastolic inter-arm blood pressure difference. The prevalence of systolic and diastolic inter-arm difference between 6 to 10 mmHg was 31.4% and 27.9% respectively. Mean systolic inter-arm blood pressure difference was significantly higher among those patients had a multisystem disorder (10.57±0.98 mmHg) and followed by patients with cardiovascular disease (10.22±0.67 mmHg) as compared to healthy patients (2.71±0.96 mmHg). Various diseases highly influenced the increase in blood pressure irrespective of systolic or diastolic was confirmed strongly significant (pdifferent inter arm blood pressure difference levels. This study supports the view of inter-arm blood pressure difference as an alarming stage of increased disease risk that incorporated to investigate potential problems at an early diagnostic stage. A significant mean difference between left and right arm blood pressure recorded for many diseases.

  2. Optimization on robot arm machining by using genetic algorithms

    Science.gov (United States)

    Liu, Tung-Kuan; Chen, Chiu-Hung; Tsai, Shang-En

    2007-12-01

    In this study, an optimization problem on the robot arm machining is formulated and solved by using genetic algorithms (GAs). The proposed approach adopts direct kinematics model and utilizes GA's global search ability to find the optimum solution. The direct kinematics equations of the robot arm are formulated and can be used to compute the end-effector coordinates. Based on these, the objective of optimum machining along a set of points can be evolutionarily evaluated with the distance between machining points and end-effector positions. Besides, a 3D CAD application, CATIA, is used to build up the 3D models of the robot arm, work-pieces and their components. A simulated experiment in CATIA is used to verify the computation results first and a practical control on the robot arm through the RS232 port is also performed. From the results, this approach is proved to be robust and can be suitable for most machining needs when robot arms are adopted as the machining tools.

  3. A Scintigraphic Method for Quantitation of Lymphatic Function in Arm Lymphedema

    DEFF Research Database (Denmark)

    Hvidsten, Svend; Toyserkani, Navid M; Sørensen, Jens A

    2018-01-01

    ) measure of lymph fluid passing through the arm. METHODS AND RESULTS: Eleven patients, aged 34-68 years, with unilateral arm lymphedema following breast cancer treatment underwent simultaneous bilateral lymphoscintigraphy using intradermal injection of 99mTc-labeled human serum albumin (HSA). Imaging...... was performed at 30-45 minute intervals for 5 hours. Time activity curves from each injection site and each arm region were recorded. The input into the arm region was obtained as the (minus) time derivative of the injection site activity curve. In the proposed model the arm activity curve was considered...

  4. Thermal–Hydrodynamic Behaviour of Coated Pivoted Pad Thrust Bearings: Comparison between Babbitt, PTFE and DLC

    OpenAIRE

    Konstantinos Katsaros; Dimitrios A. Bompos; Pantelis G. Nikolakopoulos; Stephanos Theodossiades

    2018-01-01

    The hydrodynamic lubrication and thermal analysis of tilting pad thrust bearings has been a major subject for many studies in the field of tribology. There is only a limited number of studies regarding thrust bearings with coated surfaces. The purpose of this study is to build a parametric, iterative algorithm in order to perform a complete thermal and hydrodynamic lubrication analysis for pivoted pad thrust bearings with coatings. The analytical model is mainly based on the energy, continuit...

  5. Overview of Actuated Arm Support Systems and Their Applications

    Directory of Open Access Journals (Sweden)

    E.A. Lomonova

    2013-10-01

    Full Text Available Arm support systems provide support throughout daily tasks, training or in an industrial environment. During the last decades a large diversity of actuated arm support systems have been developed. To analyze the actuation principles in these systems, an overview of actuated arm support systems is provided. This overview visualizes the current trends on research and development of these support systems and distinguishes three categories. These categories depend mainly on the functional status of the user environment, which defines the specifications. Therefore, the actuated arm support systems are classified according to their user environment, namely: ambulatory, rehabilitation and industrial. Furthermore, three main actuation principles and three mechanical construction principles have been identified.

  6. Mid-upper-arm-circumference and mid-upper-arm circumference z-score

    DEFF Research Database (Denmark)

    Rasmussen, J; Andersen, A; Fisker, A B

    2012-01-01

    Mid-upper-arm circumference (MUAC) is a simple method of assessing nutritional status in children above 6 months of age. In 2007 World Health Organization (WHO) introduced a MUAC z-score for children above 3 months of age. We evaluated whether MUAC or MUAC z-score had the best ability to identify...

  7. New design of care: Assessment of an interdisciplinary orthopaedic clinic with a pivot nurse in the province of Quebec.

    Science.gov (United States)

    Poder, Thomas G; Bellemare, Christian; Bédard, Suzanne K; He, Jie; Lemieux, Renald

    2010-01-01

    New designs of care in orthopaedic clinics are needed to cope with the shortage of orthopaedic surgeons and the lengthening of waiting times. To assess the effectiveness of an interdisciplinary orthopaedic clinic with a pivot nurse in the Canadian province of Quebec with regard to accessibility, quality of care, efficacy and efficiency of the clinic, and patient's quality of life. Two strategies were developed: (1) a selected cohort of new patients attending an orthopaedic service from February to September 2008 were entered into a database recording patient details, source of referral, diagnosis, satisfaction, and quality of life (36-Item Short Form Health Survey version 2). In this setting, 2 sets of questionnaires were administered to the patients: the first one during the first visit and the second one, 2 months later. A total of 243 patients from the case control were compared with 89 patients of the case study, where an interdisciplinary orthopaedic clinic with a pivot nurse has been developed; (2) costs per patient were calculated using the staff timesheets provided by the two orthopaedic clinics. The results showed a significant reduction in the waiting-list duration (accessibility) in the case study clinic owing to a strong decrease in the inappropriate consultations with the orthopaedic consultant. The quality of care remained high, and the target surgeries for total hip and knee replacement were reached, despite a strong shortage of orthopaedic doctors. Interdisciplinary orthopaedic clinic with a pivot nurse is a new approach in the province of Quebec and first results are encouraging.

  8. Registration of 2D C-Arm and 3D CT Images for a C-Arm Image-Assisted Navigation System for Spinal Surgery

    Directory of Open Access Journals (Sweden)

    Chih-Ju Chang

    2015-01-01

    Full Text Available C-Arm image-assisted surgical navigation system has been broadly applied to spinal surgery. However, accurate path planning on the C-Arm AP-view image is difficult. This research studies 2D-3D image registration methods to obtain the optimum transformation matrix between C-Arm and CT image frames. Through the transformation matrix, the surgical path planned on preoperative CT images can be transformed and displayed on the C-Arm images for surgical guidance. The positions of surgical instruments will also be displayed on both CT and C-Arm in the real time. Five similarity measure methods of 2D-3D image registration including Normalized Cross-Correlation, Gradient Correlation, Pattern Intensity, Gradient Difference Correlation, and Mutual Information combined with three optimization methods including Powell’s method, Downhill simplex algorithm, and genetic algorithm are applied to evaluate their performance in converge range, efficiency, and accuracy. Experimental results show that the combination of Normalized Cross-Correlation measure method with Downhill simplex algorithm obtains maximum correlation and similarity in C-Arm and Digital Reconstructed Radiograph (DRR images. Spine saw bones are used in the experiment to evaluate 2D-3D image registration accuracy. The average error in displacement is 0.22 mm. The success rate is approximately 90% and average registration time takes 16 seconds.

  9. Dichromatic State Sum Models for Four-Manifolds from Pivotal Functors

    Science.gov (United States)

    Bärenz, Manuel; Barrett, John

    2017-11-01

    A family of invariants of smooth, oriented four-dimensional manifolds is defined via handle decompositions and the Kirby calculus of framed link diagrams. The invariants are parametrised by a pivotal functor from a spherical fusion category into a ribbon fusion category. A state sum formula for the invariant is constructed via the chain-mail procedure, so a large class of topological state sum models can be expressed as link invariants. Most prominently, the Crane-Yetter state sum over an arbitrary ribbon fusion category is recovered, including the nonmodular case. It is shown that the Crane-Yetter invariant for nonmodular categories is stronger than signature and Euler invariant. A special case is the four-dimensional untwisted Dijkgraaf-Witten model. Derivations of state space dimensions of TQFTs arising from the state sum model agree with recent calculations of ground state degeneracies in Walker-Wang models. Relations to different approaches to quantum gravity such as Cartan geometry and teleparallel gravity are also discussed.

  10. Systems Approach to Arms Control Verification

    Energy Technology Data Exchange (ETDEWEB)

    Allen, K; Neimeyer, I; Listner, C; Stein, G; Chen, C; Dreicer, M

    2015-05-15

    Using the decades of experience of developing concepts and technologies for verifying bilateral and multilateral arms control agreements, a broad conceptual systems approach is being developed that takes into account varying levels of information and risk. The IAEA has already demonstrated the applicability of a systems approach by implementing safeguards at the State level, with acquisition path analysis as the key element. In order to test whether such an approach could also be implemented for arms control verification, an exercise was conducted in November 2014 at the JRC ITU Ispra. Based on the scenario of a hypothetical treaty between two model nuclear weapons states aimed at capping their nuclear arsenals at existing levels, the goal of this exercise was to explore how to use acquisition path analysis in an arms control context. Our contribution will present the scenario, objectives and results of this exercise, and attempt to define future workshops aimed at further developing verification measures that will deter or detect treaty violations.

  11. Smooth-arm spiral galaxies: their properties and significance to cluster-galaxy evolution

    International Nuclear Information System (INIS)

    Wilkerson, M.S.

    1979-01-01

    In this dissertation a number of galaxies with optical appearances between those of normal, actively-star-forming spirals and SO galaxies have been examined. These so-called smooth-arm spiral galaxies exhibit spiral arms without any of the spiral tracers - H II regions, O-B star associations, dust - indicative of current star formation. Tests were made to find if, perhaps, these smooth-arm spirals could have, at one time, been normal, actively-star-forming spirals whose gas had been somehow removed; and that are currently transforming into SO galaxies. This scenario proceeds as (1) removal of gas, (2) gradual dying of disk density wave, (3) emergence of SO galaxy. If the dominant method of gas removal is ram-pressure stripping by a hot, intracluster medium, then smooth-arm spirals should occur primarily in x-ray clusters. Some major findings of this dissertation are as follows: (1) Smooth-arm spirals are redder than normal spirals of the same morphological type. Most smooth-arm spirals cannot be distinguished by color from SO galaxies. (2) A weak trend exists for smooth-arm spirals with stronger arms to be bluer than those with weaker arms; thus implying that the interval since gas removal has been shorter for the galaxies with stronger arms. (3) Smooth-arm spirals are deficient in neutral hydrogen - sometimes by an order of magnitude or, possibly, more

  12. Dynamic model of the octopus arm. II. Control of reaching movements.

    Science.gov (United States)

    Yekutieli, Yoram; Sagiv-Zohar, Roni; Hochner, Binyamin; Flash, Tamar

    2005-08-01

    The dynamic model of the octopus arm described in the first paper of this 2-part series was used here to investigate the neural strategies used for controlling the reaching movements of the octopus arm. These are stereotypical extension movements used to reach toward an object. In the dynamic model, sending a simple propagating neural activation signal to contract all muscles along the arm produced an arm extension with kinematic properties similar to those of natural movements. Control of only 2 parameters fully specified the extension movement: the amplitude of the activation signal (leading to the generation of muscle force) and the activation traveling time (the time the activation wave takes to travel along the arm). We found that the same kinematics could be achieved by applying activation signals with different activation amplitudes all exceeding some minimal level. This suggests that the octopus arm could use minimal amplitudes of activation to generate the minimal muscle forces required for the production of the desired kinematics. Larger-amplitude signals would generate larger forces that increase the arm's stability against perturbations without changing the kinematic characteristics. The robustness of this phenomenon was demonstrated by examining activation signals with either a constant or a bell-shaped velocity profile. Our modeling suggests that the octopus arm biomechanics may allow independent control of kinematics and resistance to perturbation during arm extension movements.

  13. Parâmetros de desempenho de dezesseis equipamentos de irrigação por pivô central Parameters of performance of sixteen center-pivot irrigation equipments

    Directory of Open Access Journals (Sweden)

    Delvio Sandri

    2009-02-01

    Full Text Available O tempo de uso de sistemas de irrigação por pivô central pode resultar em alteração de suas características hidráulicas, necessitando de avaliações periódicas para manter a uniformidade de distribuição de água em níveis aceitáveis. Objetivou-se, neste trabalho, avaliar as condições de funcionamento e desempenho de dezesseis pivôs centrais, localizados em onze municípios de Goiás e no Distrito Federal. Estimou-se o coeficiente de uniformidade de Heermann & Hein - CUH e uniformidade de distribuição - CUD, variação da lâmina coletada em relação à projetada e os fatores que interferem no desempenho dos equipamentos. Dos pivôs avaliados, quatro (25% apresentaram CUH inadequado (The time of use of the center-pivot irrigation system may result in alteration of the hydraulic characteristics, frequent evaluations being needed to maintain the efficiency of water distribution at acceptable levels. The aim of this work was to evaluate the conditions of the use and the performance of sixteen center pivots, located in eleven municipal districts of Goiás State and Federal District, Brazil. The Heermann & Hein - CUH coefficient of uniformity and coefficient of distribution - CUD, variation between the collected and projected depth and verification of the main factors that influenced the performance were evaluated. Among the evaluated pivots, four (25% presented inadequate CUH (< 80% and three (18.75% presented inadequate CUD (< 70%. The average depth applied was higher than the projected in three and lower in thirteen pivots, with the difference higher than 10% in only one pivot. Most of the evaluated pivots need maintenance to solve the following problems: emitters with flow rate different from the flow considered appropriate for some intervals of the equipments; emitters totally or partially clogged or damaged; absence of suspension strings; damaged pressure regulators; leaks in several points and speed displacement different

  14. Soil water balance calculation using a two source energy balance model and wireless sensor arrays aboard a center pivot

    Science.gov (United States)

    Recent developments in wireless sensor technology and remote sensing algorithms, coupled with increased use of center pivot irrigation systems, have removed several long-standing barriers to adoption of remote sensing for real-time irrigation management. One remote sensing-based algorithm is a two s...

  15. A prognostic scoring system for arm exercise stress testing.

    Science.gov (United States)

    Xie, Yan; Xian, Hong; Chandiramani, Pooja; Bainter, Emily; Wan, Leping; Martin, Wade H

    2016-01-01

    Arm exercise stress testing may be an equivalent or better predictor of mortality outcome than pharmacological stress imaging for the ≥50% for patients unable to perform leg exercise. Thus, our objective was to develop an arm exercise ECG stress test scoring system, analogous to the Duke Treadmill Score, for predicting outcome in these individuals. In this retrospective observational cohort study, arm exercise ECG stress tests were performed in 443 consecutive veterans aged 64.1 (11.1) years. (mean (SD)) between 1997 and 2002. From multivariate Cox models, arm exercise scores were developed for prediction of 5-year and 12-year all-cause and cardiovascular mortality and 5-year cardiovascular mortality or myocardial infarction (MI). Arm exercise capacity in resting metabolic equivalents (METs), 1 min heart rate recovery (HRR) and ST segment depression ≥1 mm were the stress test variables independently associated with all-cause and cardiovascular mortality by step-wise Cox analysis (all pstatistic of 0.81 before and 0.88 after adjustment for significant demographic and clinical covariates. Arm exercise scores for the other outcome end points yielded C-statistic values of 0.77-0.79 before and 0.82-0.86 after adjustment for significant covariates versus 0.64-0.72 for best fit pharmacological myocardial perfusion imaging models in a cohort of 1730 veterans who were evaluated over the same time period. Arm exercise scores, analogous to the Duke Treadmill Score, have good power for prediction of mortality or MI in patients who cannot perform leg exercise.

  16. The purposes, achievements, and priorities of arms control

    International Nuclear Information System (INIS)

    Brown, P.S.

    1987-09-01

    Arms control purposes include strengthening the framework of deterrence and reducing the threat of the use of nuclear weapons, reducing the dangers of attack and accidental nuclear war, and allowing more resources for the civilian economy. The paper briefly describes achievements in arms control since World War II. These include the Limited Test Ban Treaty (LTBT), Nonproliferation Treaty (NPT), Anti-Ballistic Missile Treaty (ABMT)-SALT I, SALT II, Threshold Test Ban Treaty (TTBT), Peaceful Nuclear Explosions Treaty (PNET), and Nuclear-Free Zones treaties. The author also discusses his views on what the priorities of arms control activities should be

  17. Beyond arms control? Looking for the lost paradigm.

    International Nuclear Information System (INIS)

    Dahan, P.

    2002-01-01

    Since the tragic events of September 11, 2001, the international relations have become more complex and the arms control concept, born during the cold war and implemented during the 3 last decades is today marking time. Disarmament and non-proliferation, which were the keystones of arms control and international negotiations, are today undergoing erosion. This article analyzes the change of situation between the end of the 20. century and the beginning of the 21. century. Three steps are defined by the author: a 'flux' step with the signature of a huge number of international agreements about non-proliferation and arms control, a stagnation step marked by the difficulties of implementing some of the existing treaties and by the violation by some states of some of them, and a 'reflux' step marked by a freezing up of the bilateral US-Russian disarmament process and a general renouncement of the multilateral arms control concept. (J.S.)

  18. Comparison of upper arm and forearm blood pressure.

    Science.gov (United States)

    Domiano, Kathy L; Hinck, Susan M; Savinske, Debra L; Hope, Kathryn L

    2008-11-01

    The upper arm is the primary site used to obtain a blood pressure measurement (BPM); however, when it is not possible to use the upper arm, the forearm is a commonly used alternate site. This study determines if there is a significant difference between upper arm and forearm BPMs among adults and examines the relationship of participant characteristics to the BPM difference. A convenience sample was recruited from a low-income, independent-living, 104-apartment complex in the Midwest. Of the 106 participants, 64% were female and 89% were White. Ages ranged from 20 to 85 years (M = 50.7). The investigators calculated the BMIs (range = 18 to 42, M = 29.3, SD = 5.4) for the 89% (n = 94) of participants who reported their weight. The forearm tended to have higher BPMs than the upper arm (M difference = 4.0 mm Hg systolic, 2.3 mm Hg diastolic). However, site differences were greatest for men, obese adults, and middle aged (36 to 65) adults.

  19. Counting Zeros in Random Walks on the Integers and Analysis of Optimal Dual-Pivot Quicksort

    DEFF Research Database (Denmark)

    Aumüller, Martin; Dietzfelbinger, Martin; Heuberger, Clemens

    2016-01-01

    We present an average case analysis of two variants of dual-pivot quicksort, one with a non-algorithmic comparison-optimal partitioning strategy, the other with a closely related algorithmic strategy. For both we calculate the expected number of comparisons exactly as well as asymptotically......, in particular, we provide exact expressions for the linear, logarithmic, and constant terms. An essential step is the analysis of zeros of lattice paths in a certain probability model. Along the way a combinatorial identity is proven....

  20. ARM Operations and Engineering Procedure Mobile Facility Site Startup

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, Jimmy W

    2015-05-01

    This procedure exists to define the key milestones, necessary steps, and process rules required to commission and operate an Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF), with a specific focus toward on-time product delivery to the ARM Data Archive. The overall objective is to have the physical infrastructure, networking and communications, and instrument calibration, grooming, and alignment (CG&A) completed with data products available from the ARM Data Archive by the Operational Start Date milestone.

  1. WORKSPACE DRAWING FROM A MANIPULATOR ARM WITH 6 DOF

    Directory of Open Access Journals (Sweden)

    NAIDIN Gigi

    2011-06-01

    Full Text Available Modelling and simulation is an important aspect in robotic field. Knowing of the workspace is very important to the operation of manipulators arm. This paper investigates operational performance of space manipulator arm destined for industrial manufacturing, by defining and analyzing their workspace and manipulability measure. The authors show that manipulator arm developing requires the consideration of more efficient dynamic models and use of dedicated processing techniques such as Autodesk-Inventor 9, MATLAB, WorkSpace software.

  2. Chaotic evolution of arms races

    Science.gov (United States)

    Tomochi, Masaki; Kono, Mitsuo

    1998-12-01

    A new set of model equations is proposed to describe the evolution of the arms race, by extending Richardson's model with special emphases that (1) power dependent defensive reaction or historical enmity could be a motive force to promote armaments, (2) a deterrent would suppress the growth of armaments, and (3) the defense reaction of one nation against the other nation depends nonlinearly on the difference in armaments between two. The set of equations is numerically solved to exhibit stationary, periodic, and chaotic behavior depending on the combinations of parameters involved. The chaotic evolution is realized when the economic situation of each country involved in the arms race is quite different, which is often observed in the real world.

  3. Information booklet on personal protective equipment: arm and hand protection

    International Nuclear Information System (INIS)

    1992-01-01

    Fire, heat, cold, electro-magnetic and ionising radiation, electricity, chemicals, impacts, cuts, abrasion, etc. are the common hazards for arms and hands at work. The gloves chosen for protection of the arm and hand should cover those parts adequately and the material of the gloves should be capable of offering protection against the specific hazard involved. Criteria for choosing arm and hand protection equipment will be based on their shape and part of the arm and hand protected. Guide lines for choosing such personal protection equipment for nuclear facilities are given. (M.K.V.). 3 annexures, 1 appendix

  4. The arms race control; Le controle de la course aux armements

    Energy Technology Data Exchange (ETDEWEB)

    Nemo, J.

    2010-07-15

    Written in 1961, this paper presents the content of a book entitled 'The arms race control' where the author outlined the difference between disarmament and arms control, described the economic and moral role of arms race, the importance of force balance for international security. He wandered whether arms control could ensure this balance and whether nuclear balance meant force balance. Force balance then appears to be a precarious and unsteady component of international security. He commented the challenges of disarmament, recalled some arguments for a nuclear disarmament. Then he discussed what would be an arms control with or without disarmament (either nuclear or conventional)

  5. Beyond arms control? Looking for the lost paradigm..; Au-dela de l'arms control? A la recherche du paradigme perdu..

    Energy Technology Data Exchange (ETDEWEB)

    Dahan, P

    2002-07-01

    Since the tragic events of September 11, 2001, the international relations have become more complex and the arms control concept, born during the cold war and implemented during the 3 last decades is today marking time. Disarmament and non-proliferation, which were the keystones of arms control and international negotiations, are today undergoing erosion. This article analyzes the change of situation between the end of the 20. century and the beginning of the 21. century. Three steps are defined by the author: a 'flux' step with the signature of a huge number of international agreements about non-proliferation and arms control, a stagnation step marked by the difficulties of implementing some of the existing treaties and by the violation by some states of some of them, and a 'reflux' step marked by a freezing up of the bilateral US-Russian disarmament process and a general renouncement of the multilateral arms control concept. (J.S.)

  6. Coat of Arms.

    Science.gov (United States)

    Smith, Bryan

    1998-01-01

    Describes an activity, the "coat of arms," that can serve as an ice-breaker or warm-up for the first day of an English-as-a-Second/Foreign-Language class, as a motivating start to the week, or act as an innovative segue between skill lessons. The technique can be adapted for students ranging from elementary school to adult language learners of all…

  7. The MVACS Robotic Arm Camera

    Science.gov (United States)

    Keller, H. U.; Hartwig, H.; Kramm, R.; Koschny, D.; Markiewicz, W. J.; Thomas, N.; Fernades, M.; Smith, P. H.; Reynolds, R.; Lemmon, M. T.; Weinberg, J.; Marcialis, R.; Tanner, R.; Boss, B. J.; Oquest, C.; Paige, D. A.

    2001-08-01

    The Robotic Arm Camera (RAC) is one of the key instruments newly developed for the Mars Volatiles and Climate Surveyor payload of the Mars Polar Lander. This lightweight instrument employs a front lens with variable focus range and takes images at distances from 11 mm (image scale 1:1) to infinity. Color images with a resolution of better than 50 μm can be obtained to characterize the Martian soil. Spectral information of nearby objects is retrieved through illumination with blue, green, and red lamp sets. The design and performance of the camera are described in relation to the science objectives and operation. The RAC uses the same CCD detector array as the Surface Stereo Imager and shares the readout electronics with this camera. The RAC is mounted at the wrist of the Robotic Arm and can characterize the contents of the scoop, the samples of soil fed to the Thermal Evolved Gas Analyzer, the Martian surface in the vicinity of the lander, and the interior of trenches dug out by the Robotic Arm. It can also be used to take panoramic images and to retrieve stereo information with an effective baseline surpassing that of the Surface Stereo Imager by about a factor of 3.

  8. Inertial sensors to quantify the pivot shift test in the treatment of anterior cruciate ligament injury

    OpenAIRE

    ZAFFAGNINI, STEFANO; LOPOMO, NICOLA; SIGNORELLI, CECILIA; MUCCIOLI, GIULIO MARIA MARCHEGGIANI; BONANZINGA, TOMMASO; GRASSI, ALBERTO; RAGGI, FEDERICO; VISANI, ANDREA; MARCACCI, MAURILIO

    2014-01-01

    The main purpose of this article was to describe in detail, from the perspective of the clinical end user, a previously presented non-invasive methodology, applied in the treatment of anterior cruciate ligament injury, in which inertial sensors are used to quantify the pivot shift test. The outcomes obtained and relative considerations were compared with findings emerging from a review of the relevant updated literature. The detailed description here provided covers the system, the parameters...

  9. Hysteresis of targeting civilians in armed conflicts

    OpenAIRE

    Uih Ran Lee

    2015-01-01

    This article explores warring groups’ intentional targeting behavior against civilians, a strictly prohibited war strategy by international norms. Using dynamic panel regressions run on a comprehensive dataset of contemporary warfare which covers 22 years (1989-2010), I find that warring actors, both sovereign states and formally organized armed groups, behave systematically in terms of civilian targeting when they are involved in prolonged armed conflict (15-22 years). Warring actors’ lethal...

  10. Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis

    International Nuclear Information System (INIS)

    Dehghan, Ehsan; Moradi, Mehdi; Wen, Xu; French, Danny; Lobo, Julio; Morris, W. James; Salcudean, Septimiu E.; Fichtinger, Gabor

    2011-01-01

    Purpose: Accurate localization of prostate implants from several C-arm images is necessary for ultrasound-fluoroscopy fusion and intraoperative dosimetry. The authors propose a computational motion compensation method for tomosynthesis-based reconstruction that enables 3D localization of prostate implants from C-arm images despite C-arm oscillation and sagging. Methods: Five C-arm images are captured by rotating the C-arm around its primary axis, while measuring its rotation angle using a protractor or the C-arm joint encoder. The C-arm images are processed to obtain binary seed-only images from which a volume of interest is reconstructed. The motion compensation algorithm, iteratively, compensates for 2D translational motion of the C-arm by maximizing the number of voxels that project on a seed projection in all of the images. This obviates the need for C-arm full pose tracking traditionally implemented using radio-opaque fiducials or external trackers. The proposed reconstruction method is tested in simulations, in a phantom study and on ten patient data sets. Results: In a phantom implanted with 136 dummy seeds, the seed detection rate was 100% with a localization error of 0.86 ± 0.44 mm (Mean ± STD) compared to CT. For patient data sets, a detection rate of 99.5% was achieved in approximately 1 min per patient. The reconstruction results for patient data sets were compared against an available matching-based reconstruction method and showed relative localization difference of 0.5 ± 0.4 mm. Conclusions: The motion compensation method can successfully compensate for large C-arm motion without using radio-opaque fiducial or external trackers. Considering the efficacy of the algorithm, its successful reconstruction rate and low computational burden, the algorithm is feasible for clinical use.

  11. Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Dehghan, Ehsan; Moradi, Mehdi; Wen, Xu; French, Danny; Lobo, Julio; Morris, W. James; Salcudean, Septimiu E.; Fichtinger, Gabor [School of Computing, Queen' s University, Kingston, Ontario K7L-3N6 (Canada); Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia V6T-1Z4 (Canada); Vancouver Cancer Centre, Vancouver, British Columbia V5Z-1E6 (Canada); Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia V6T-1Z4 (Canada); School of Computing, Queen' s University, Kingston, Ontario K7L-3N6 (Canada)

    2011-10-15

    Purpose: Accurate localization of prostate implants from several C-arm images is necessary for ultrasound-fluoroscopy fusion and intraoperative dosimetry. The authors propose a computational motion compensation method for tomosynthesis-based reconstruction that enables 3D localization of prostate implants from C-arm images despite C-arm oscillation and sagging. Methods: Five C-arm images are captured by rotating the C-arm around its primary axis, while measuring its rotation angle using a protractor or the C-arm joint encoder. The C-arm images are processed to obtain binary seed-only images from which a volume of interest is reconstructed. The motion compensation algorithm, iteratively, compensates for 2D translational motion of the C-arm by maximizing the number of voxels that project on a seed projection in all of the images. This obviates the need for C-arm full pose tracking traditionally implemented using radio-opaque fiducials or external trackers. The proposed reconstruction method is tested in simulations, in a phantom study and on ten patient data sets. Results: In a phantom implanted with 136 dummy seeds, the seed detection rate was 100% with a localization error of 0.86 {+-} 0.44 mm (Mean {+-} STD) compared to CT. For patient data sets, a detection rate of 99.5% was achieved in approximately 1 min per patient. The reconstruction results for patient data sets were compared against an available matching-based reconstruction method and showed relative localization difference of 0.5 {+-} 0.4 mm. Conclusions: The motion compensation method can successfully compensate for large C-arm motion without using radio-opaque fiducial or external trackers. Considering the efficacy of the algorithm, its successful reconstruction rate and low computational burden, the algorithm is feasible for clinical use.

  12. STRUCTURED MOLECULAR GAS REVEALS GALACTIC SPIRAL ARMS

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, Tsuyoshi [Joint ALMA Office, Alonso de Cordova 3107, Vitacura, Santiago 763-0355 (Chile); Hasegawa, Tetsuo [NAOJ Chile Observatory, Joaquin Montero 3000 Oficina 702, Vitacura, Santiago 763-0409 (Chile); Koda, Jin, E-mail: sawada.tsuyoshi@nao.ac.jp [Department of Physics and Astronomy, Stony Brook University, Stony Brook, NY 11794-3800 (United States)

    2012-11-01

    We explore the development of structures in molecular gas in the Milky Way by applying the analysis of the brightness distribution function and the brightness distribution index (BDI) in the archival data from the Boston University-Five College Radio Astronomy Observatory {sup 13}CO J = 1-0 Galactic Ring Survey. The BDI measures the fractional contribution of spatially confined bright molecular emission over faint emission extended over large areas. This relative quantity is largely independent of the amount of molecular gas and of any conventional, pre-conceived structures, such as cores, clumps, or giant molecular clouds. The structured molecular gas traced by higher BDI is located continuously along the spiral arms in the Milky Way in the longitude-velocity diagram. This clearly indicates that molecular gas changes its structure as it flows through the spiral arms. Although the high-BDI gas generally coincides with H II regions, there is also some high-BDI gas with no/little signature of ongoing star formation. These results support a possible evolutionary sequence in which unstructured, diffuse gas transforms itself into a structured state on encountering the spiral arms, followed by star formation and an eventual return to the unstructured state after the spiral arm passage.

  13. Arm reduced robotic-assisted laparoscopic hysterectomy with transvaginal cuff closure.

    Science.gov (United States)

    Bodur, Serkan; Dede, Murat; Fidan, Ulas; Firatligil, Burcin F; Ulubay, Mustafa; Ozturk, Mustafa; Yenen, Mufit C

    2017-09-01

    The use of robotics for benign etiology in gynecology has not proven to be more beneficial when compared to traditional laparoscopy. The major concern regarding robotic hysterectomy stems from its high cost. To evaluate the clinical utility and effectiveness of one-arm reduced robotic-assisted laparoscopic hysterectomy as a cost-effective surgical option for total robotic hysterectomy. A sample population of 54 women who underwent robotic-assisted laparoscopic surgery for benign gynecologic indications was evaluated, and two groups were identified: (1) the two-armed robotic-assisted laparoscopic surgery group (n = 38 patients), and (2) the three-armed robotic-assisted laparoscopic surgery group (n = 16 patients). An increased cost was observed when three-armed robotic surgery was employed for benign gynecologic surgery (p < 0.001). The cost reduction observed in the study group was primarily derived from one robotic arm reduction and vaginal closure of the cuff. This cost reduction was achieved without an increase in complication rates or undesirable postoperative outcomes. An estimated profit between $399.5 and $421.5 was made for each patient depending on the suture material chosen for cuff closure. Two-armed surgery resulted in an 18.6% reduction in procedure-specific costs for robotic hysterectomy. Two-armed robotic-assisted laparoscopic hysterectomy appears to be a cost-effective solution for robotic gynecologic surgery. This surgical solution can be performed as effectively as classical three-armed robotic hysterectomies for benign indications without the risk of increased surgical-related morbidities. This approach has the potential to be a widely preferred surgical approach in medical communities where cost reduction is one of the primary determinants of surgery type.

  14. Feasibility of a Short-Arm Centrifuge for Mouse Hypergravity Experiments.

    Science.gov (United States)

    Morita, Hironobu; Obata, Koji; Abe, Chikara; Shiba, Dai; Shirakawa, Masaki; Kudo, Takashi; Takahashi, Satoru

    2015-01-01

    To elucidate the pure impact of microgravity on small mammals despite uncontrolled factors that exist in the International Space Station, it is necessary to construct a 1 g environment in space. The Japan Aerospace Exploration Agency has developed a novel mouse habitat cage unit that can be installed in the Cell Biology Experiment Facility in the Kibo module of the International Space Station. The Cell Biology Experiment Facility has a short-arm centrifuge to produce artificial 1 g gravity in space for mouse experiments. However, the gravitational gradient formed inside the rearing cage is larger when the radius of gyration is shorter; this may have some impact on mice. Accordingly, biological responses to hypergravity induced by a short-arm centrifuge were examined and compared with those induced by a long-arm centrifuge. Hypergravity induced a significant Fos expression in the central nervous system, a suppression of body mass growth, an acute and transient reduction in food intake, and impaired vestibulomotor coordination. There was no difference in these responses between mice raised in a short-arm centrifuge and those in a long-arm centrifuge. These results demonstrate the feasibility of using a short-arm centrifuge for mouse experiments.

  15. Tracked Robot with Blade Arms to Enhance Crawling Capability

    OpenAIRE

    Jhu-Wei Ji; Fa-Shian Chang; Lih-Tyng Hwang; Chih-Feng Liu; Jeng-Nan Lee; Shun-Min Wang; Kai-Yi Cho

    2016-01-01

    This paper presents a tracked robot with blade arms powered to assist movement in difficult environments. As a result, the tracked robot is able to pass a ramp or climb stairs. The main feature is a pair of blade arms on both sides of the vehicle body working in collaboration with previously validated transformable track system. When the robot encounters an obstacle in a terrain, it enlists the blade arms with power to overcome the obstacle. In disaster areas, there usually will be terrains t...

  16. Difference in blood pressure measurements between arms: methodological and clinical implications.

    Science.gov (United States)

    Clark, Christopher E

    2015-01-01

    Differences in blood pressure measurements between arms are commonly encountered in clinical practice. If such differences are not excluded they can delay the diagnosis of hypertension and can lead to poorer control of blood pressure levels. Differences in blood pressure measurements between arms are associated cross sectionally with other signs of vascular disease such as peripheral arterial disease or cerebrovascular disease. Differences are also associated prospectively with increased cardiovascular mortality and morbidity and all cause mortality. Numbers of publications on inter-arm difference are rising year on year, indicating a growing interest in the phenomenon. The prevalence of an inter-arm difference varies widely between reports, and is correlated with the underlying cardiovascular risk of the population studied. Prevalence is also sensitive to the method of measurement used. This review discusses the prevalence of an inter-arm difference in different populations and addresses current best practice for the detection and the measurement of a difference. The evidence for clinical and for vascular associations of an inter-arm difference is presented in considering the emerging role of an inter-arm blood pressure difference as a novel risk factor for increased cardiovascular morbidity and mortality. Competing aetiological explanations for an inter-arm difference are explored, and gaps in our current understanding of this sign, along with areas in need of further research, are considered.

  17. C-arm CT for planning and guidance of extrahepatic embolizations

    International Nuclear Information System (INIS)

    Wacker, F.K.; Meissner, O.A.; Meyer, B.C.

    2009-01-01

    Interventional radiological vascular embolizations are complex procedures that require exact imaging of the target region to facilitate safe and effective treatment. The purpose of this paper is to present the technique and feasibility of flat detector C-arm computed tomography (C-arm CT) for control and guidance of extrahepatic abdominal embolization procedures. C-arm CT images can provide important information on both vascular and cross-sectional anatomy of the target region, help in determining therapy endpoints and provide follow-up during and immediately after the abdominal interventions.The cases presented demonstrate that C-arm CT images are beneficial for abdominal embolization procedures and facilitate precise treatment. (orig.) [de

  18. Co-Simulation Control of Robot Arm Dynamics in ADAMS and MATLAB

    OpenAIRE

    Luo Haitao; Liu Yuwang; Chen Zhengcang; Leng Yuquan

    2013-01-01

    The main objective of this study is how to quickly establish the virtual prototyping model of robot arm system and effectively solve trajectory tracking control for a given signal. Taking the 2-DOF robot arm as an example, a co-simulation control method is introduced to research multi-body dynamics. Using Newton-Euler and Lagrange method, respectively establish the dynamics model of robot arm and verify the correctness of equations. Firstly, the physical model of robot arm was built by PROE a...

  19. ARM Cloud Radar Simulator Package for Global Climate Models Value-Added Product

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yuying [North Carolina State Univ., Raleigh, NC (United States); Xie, Shaocheng [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-05-01

    It has been challenging to directly compare U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility ground-based cloud radar measurements with climate model output because of limitations or features of the observing processes and the spatial gap between model and the single-point measurements. To facilitate the use of ARM radar data in numerical models, an ARM cloud radar simulator was developed to converts model data into pseudo-ARM cloud radar observations that mimic the instrument view of a narrow atmospheric column (as compared to a large global climate model [GCM] grid-cell), thus allowing meaningful comparison between model output and ARM cloud observations. The ARM cloud radar simulator value-added product (VAP) was developed based on the CloudSat simulator contained in the community satellite simulator package, the Cloud Feedback Model Intercomparison Project (CFMIP) Observation Simulator Package (COSP) (Bodas-Salcedo et al., 2011), which has been widely used in climate model evaluation with satellite data (Klein et al., 2013, Zhang et al., 2010). The essential part of the CloudSat simulator is the QuickBeam radar simulator that is used to produce CloudSat-like radar reflectivity, but is capable of simulating reflectivity for other radars (Marchand et al., 2009; Haynes et al., 2007). Adapting QuickBeam to the ARM cloud radar simulator within COSP required two primary changes: one was to set the frequency to 35 GHz for the ARM Ka-band cloud radar, as opposed to 94 GHz used for the CloudSat W-band radar, and the second was to invert the view from the ground to space so as to attenuate the beam correctly. In addition, the ARM cloud radar simulator uses a finer vertical resolution (100 m compared to 500 m for CloudSat) to resolve the more detailed structure of clouds captured by the ARM radars. The ARM simulator has been developed following the COSP workflow (Figure 1) and using the capabilities available in COSP

  20. Measurement Capabilities of the DOE ARM Aerial Facility

    Science.gov (United States)

    Schmid, B.; Tomlinson, J. M.; Hubbe, J.; Comstock, J. M.; Kluzek, C. D.; Chand, D.; Pekour, M. S.

    2012-12-01

    The Department of Energy Atmospheric Radiation Measurement (ARM) Program is a climate research user facility operating stationary ground sites in three important climatic regimes that provide long-term measurements of climate relevant properties. ARM also operates mobile ground- and ship-based facilities to conduct shorter field campaigns (6-12 months) to investigate understudied climate regimes around the globe. Finally, airborne observations by ARM's Aerial Facility (AAF) enhance the surface-based ARM measurements by providing high-resolution in situ measurements for process understanding, retrieval algorithm development, and model evaluation that is not possible using ground-based techniques. AAF started out in 2007 as a "virtual hangar" with no dedicated aircraft and only a small number of instruments owned by ARM. In this mode, AAF successfully carried out several missions contracting with organizations and investigators who provided their research aircraft and instrumentation. In 2009, the Battelle owned G-1 aircraft was included in the ARM facility. The G-1 is a large twin turboprop aircraft, capable of measurements up to altitudes of 7.5 km and a range of 2,800 kilometers. Furthermore the American Recovery and Reinvestment Act of 2009 provided funding for the procurement of seventeen new instruments to be used aboard the G-1 and other AAF virtual-hangar aircraft. AAF now executes missions in the virtual- and real-hangar mode producing freely available datasets for studying aerosol, cloud, and radiative processes in the atmosphere. AAF is also heavily engaged in the maturation and testing of newly developed airborne sensors to help foster the next generation of airborne instruments. In the presentation we will showcase science applications based on measurements from recent field campaigns such as CARES, CALWATER and TCAP.

  1. Rock Moved by Mars Lander Arm

    Science.gov (United States)

    2008-01-01

    The robotic arm on NASA's Phoenix Mars Lander slid a rock out of the way during the mission's 117th Martian day (Sept. 22, 2008) to gain access to soil that had been underneath the rock.The lander's Surface Stereo Imager took the two images for this stereo view later the same day, showing the rock, called 'Headless,' after the arm pushed it about 40 centimeters (16 inches) from its previous location. 'The rock ended up exactly where we intended it to,' said Matt Robinson of NASA's Jet Propulsion Laboratory, robotic arm flight software lead for the Phoenix team. The arm had enlarged the trench near Headless two days earlier in preparation for sliding the rock into the trench. The trench was dug to about 3 centimeters (1.2 inches) deep. The ground surface between the rock's prior position and the lip of the trench had a slope of about 3 degrees downward toward the trench. Headless is about the size and shape of a VHS videotape. The Phoenix science team sought to move the rock in order to study the soil and the depth to subsurface ice underneath where the rock had been. This image was taken at about 12:30 p.m., local solar time on Mars. The view is to the north northeast of the lander. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by JPL, Pasadena, Calif. Spacecraft development was by Lockheed Martin Space Systems, Denver.

  2. 77 FR 42707 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-07-20

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-35] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... Force (DAY) [[Page 42709

  3. ARMED CONFLICT IN CHECHNYA IN EUROPEAN (NON ENGLISH HISTORIOGRAPHY

    Directory of Open Access Journals (Sweden)

    Николай Николаевич Малишевский

    2016-12-01

    Full Text Available The article deals with the problems of historiography of the armed conflict in the Chechen Republic. The activephase of themilitary operationsofthe armed conflictin Chechnyawas completedin2001. At that timehistorians, analysts andjournalists created awide range of theoretical worksconcerningthe conflict.Inthese publications there were discussed a number of commonfeaturesofthe use ofbasicresources. The degree ofaccessibilityof the sourceswhichfocus onthe descriptionof the conflictand itssocio-political assessment is of great importance for researchersand their objectives. The author analyzes Western (European historiography of the armed conflict in the Chechen Republic. It considers the publications and specialized monographs of European (French, German and Polish authors on the subjects under research. There areput forward the ideas of the consequences of the armed conflict in the Chechen Republic, articulated in the works of European researchers.For the first time within the study of the Western historiography of the war in Chechnya the author analyzes the main blocks of the supposed and factual consequences of the conflict for both the Russian and Chechen sides. The European historiography, dedicated tothe armed conflictin Chechnya, is just being developedand thestate ofitsdocumentarycomplexis characterized bya number ofqualitative changes.

  4. New Horizons and New Strategies in Arms Control

    Energy Technology Data Exchange (ETDEWEB)

    Brown, J. editor

    1998-12-04

    In the last ten years, since the break-up of the Soviet Union, remarkable progress in arms control and disarmament has occurred. The Nuclear Non-Proliferation Treaty (NPT), the completion of the Comprehensive Test Ban Treaty (CTBT), and the Chemical Weapons Treaty (CWC) are indicative of the great strides made in the non- proliferation arena. Simultaneously, the Intermediate Nuclear Forces Treaty (INF), the Conventional Forces Treaty in Europe (CFE), and the Strategic Arms Reduction Treaties (START), all associated with US-Soviet Union (now Russia) relations have assisted in redefining European relations and the security landscape. Finally, it now appears that progress is in the offing in developing enhanced compliance measures for the Biological and Toxin Weapons Convention (BTWC). In sum, all of these achievements have set the stage for the next round of arms control activities, which may lead to a much broader, and perhaps more diffused multilateral agenda. In this new and somewhat unpredictable international setting, arms control and disarmament issues will require solutions that are both more creative and innovative than heretofore.

  5. Arm coordination in octopus crawling involves unique motor control strategies.

    Science.gov (United States)

    Levy, Guy; Flash, Tamar; Hochner, Binyamin

    2015-05-04

    To cope with the exceptional computational complexity that is involved in the control of its hyper-redundant arms [1], the octopus has adopted unique motor control strategies in which the central brain activates rather autonomous motor programs in the elaborated peripheral nervous system of the arms [2, 3]. How octopuses coordinate their eight long and flexible arms in locomotion is still unknown. Here, we present the first detailed kinematic analysis of octopus arm coordination in crawling. The results are surprising in several respects: (1) despite its bilaterally symmetrical body, the octopus can crawl in any direction relative to its body orientation; (2) body and crawling orientation are monotonically and independently controlled; and (3) contrasting known animal locomotion, octopus crawling lacks any apparent rhythmical patterns in limb coordination, suggesting a unique non-rhythmical output of the octopus central controller. We show that this uncommon maneuverability is derived from the radial symmetry of the arms around the body and the simple pushing-by-elongation mechanism by which the arms create the crawling thrust. These two together enable a mechanism whereby the central controller chooses in a moment-to-moment fashion which arms to recruit for pushing the body in an instantaneous direction. Our findings suggest that the soft molluscan body has affected in an embodied way [4, 5] the emergence of the adaptive motor behavior of the octopus. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Initial explorations of ARM processors for scientific computing

    International Nuclear Information System (INIS)

    Abdurachmanov, David; Elmer, Peter; Eulisse, Giulio; Muzaffar, Shahzad

    2014-01-01

    Power efficiency is becoming an ever more important metric for both high performance and high throughput computing. Over the course of next decade it is expected that flops/watt will be a major driver for the evolution of computer architecture. Servers with large numbers of ARM processors, already ubiquitous in mobile computing, are a promising alternative to traditional x86-64 computing. We present the results of our initial investigations into the use of ARM processors for scientific computing applications. In particular we report the results from our work with a current generation ARMv7 development board to explore ARM-specific issues regarding the software development environment, operating system, performance benchmarks and issues for porting High Energy Physics software

  7. Optimal C-arm angulation during transcatheter aortic valve replacement: Accuracy of a rotational C-arm computed tomography based three dimensional heart model.

    Science.gov (United States)

    Veulemans, Verena; Mollus, Sabine; Saalbach, Axel; Pietsch, Max; Hellhammer, Katharina; Zeus, Tobias; Westenfeld, Ralf; Weese, Jürgen; Kelm, Malte; Balzer, Jan

    2016-10-26

    To investigate the accuracy of a rotational C-arm CT-based 3D heart model to predict an optimal C-arm configuration during transcatheter aortic valve replacement (TAVR). Rotational C-arm CT (RCT) under rapid ventricular pacing was performed in 57 consecutive patients with severe aortic stenosis as part of the pre-procedural cardiac catheterization. With prototype software each RCT data set was segmented using a 3D heart model. From that the line of perpendicularity curve was obtained that generates a perpendicular view of the aortic annulus according to the right-cusp rule. To evaluate the accuracy of a model-based overlay we compared model- and expert-derived aortic root diameters. For all 57 patients in the RCT cohort diameter measurements were obtained from two independent operators and were compared to the model-based measurements. The inter-observer variability was measured to be in the range of 0°-12.96° of angular C-arm displacement for two independent operators. The model-to-operator agreement was 0°-13.82°. The model-based and expert measurements of aortic root diameters evaluated at the aortic annulus ( r = 0.79, P optimal C-arm configuration, potentially simplifying current clinical workflows before and during TAVR.

  8. Light Duty Utility Arm computer software configuration management plan

    International Nuclear Information System (INIS)

    Philipp, B.L.

    1998-01-01

    This plan describes the configuration management for the Light Duty Utility Arm robotic manipulation arm control software. It identifies the requirement, associated documents, and the software control methodology. The Light Duty Utility Ann (LDUA) System is a multi-axis robotic manipulator arm and deployment vehicle, used to perform surveillance and characterization operations in support of remediation of defense nuclear wastes currently stored in the Hanford Underground Storage Tanks (USTs) through the available 30.5 cm (12 in.) risers. This plan describes the configuration management of the LDUA software

  9. Multi-armed spirals and multi-pairs antispirals in spatial rock–paper–scissors games

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Luo-Luo, E-mail: jiangluoluo@gmail.com [College of Physics and Electronic Information Engineering, Wenzhou University, Wenzhou 325035 (China); College of Physics and Technology, Guangxi Normal University, Guilin, Guangxi 541004 (China); Wang, Wen-Xu [School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ 85287 (United States); Department of Physics, Beijing Normal University, Beijing 100875 (China); Lai, Ying-Cheng [School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ 85287 (United States); Department of Physics, Arizona State University, Tempe, AZ 85287 (United States); Ni, Xuan [School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ 85287 (United States)

    2012-07-09

    We study the formation of multi-armed spirals and multi-pairs antispirals in spatial rock–paper–scissors games with mobile individuals. We discover a set of seed distributions of species, which is able to produce multi-armed spirals and multi-pairs antispirals with a finite number of arms and pairs based on stochastic processes. The joint spiral waves are also predicted by a theoretical model based on partial differential equations associated with specific initial conditions. The spatial entropy of patterns is introduced to differentiate the multi-armed spirals and multi-pairs antispirals. For the given mobility, the spatial entropy of multi-armed spirals is higher than that of single armed spirals. The stability of the waves is explored with respect to individual mobility. Particularly, we find that both two armed spirals and one pair antispirals transform to the single armed spirals. Furthermore, multi-armed spirals and multi-pairs antispirals are relatively stable for intermediate mobility. The joint spirals with lower numbers of arms and pairs are relatively more stable than those with higher numbers of arms and pairs. In addition, comparing to large amount of previous work, we employ the no flux boundary conditions which enables quantitative studies of pattern formation and stability in the system of stochastic interactions in the absence of excitable media. -- Highlights: ► Multi-armed spirals and multi-pairs antispirals are observed. ► Patterns are predicted by computer simulations and partial differential equations. ► The spatial entropy of patterns is introduced. ► Patterns are relatively stable for intermediate mobility. ► The joint spirals with lower numbers of arms and pairs are relatively more stable.

  10. Multi-armed spirals and multi-pairs antispirals in spatial rock–paper–scissors games

    International Nuclear Information System (INIS)

    Jiang, Luo-Luo; Wang, Wen-Xu; Lai, Ying-Cheng; Ni, Xuan

    2012-01-01

    We study the formation of multi-armed spirals and multi-pairs antispirals in spatial rock–paper–scissors games with mobile individuals. We discover a set of seed distributions of species, which is able to produce multi-armed spirals and multi-pairs antispirals with a finite number of arms and pairs based on stochastic processes. The joint spiral waves are also predicted by a theoretical model based on partial differential equations associated with specific initial conditions. The spatial entropy of patterns is introduced to differentiate the multi-armed spirals and multi-pairs antispirals. For the given mobility, the spatial entropy of multi-armed spirals is higher than that of single armed spirals. The stability of the waves is explored with respect to individual mobility. Particularly, we find that both two armed spirals and one pair antispirals transform to the single armed spirals. Furthermore, multi-armed spirals and multi-pairs antispirals are relatively stable for intermediate mobility. The joint spirals with lower numbers of arms and pairs are relatively more stable than those with higher numbers of arms and pairs. In addition, comparing to large amount of previous work, we employ the no flux boundary conditions which enables quantitative studies of pattern formation and stability in the system of stochastic interactions in the absence of excitable media. -- Highlights: ► Multi-armed spirals and multi-pairs antispirals are observed. ► Patterns are predicted by computer simulations and partial differential equations. ► The spatial entropy of patterns is introduced. ► Patterns are relatively stable for intermediate mobility. ► The joint spirals with lower numbers of arms and pairs are relatively more stable.

  11. Section 504 and student health problems: the pivotal position of the school nurse.

    Science.gov (United States)

    Zirkel, Perry A; Granthom, Margarita Fernan; Lovato, Leanna

    2012-12-01

    News reports illustrate controversies between parents and schools in response to student health problems. Today's school nurse is in a pivotal position for the avoidance and resolution of disputes not only by increasing awareness of student health conditions but also by having a working knowledge of legal developments under Section 504 and its sister statute-the Americans with Disabilities Act (ADA). The ADA amendments of 2008 have extended the standards for eligibility and expanded questions about school districts' obligations under Section 504 and the ADA. This article provides a comprehensive synthesis of recent case law and related legal developments under this pair of federal statutes, culminating in practical implications and professional recommendations for school nurses.

  12. EU Armed Forces' Use of Social Media in Areas of Deployment

    OpenAIRE

    Hellman, Maria; Olsson, Eva-Karin; Wagnsson, Charlotte

    2016-01-01

    The advent of social media can be seen both as a risk and an opportunity by armed forces. Previous research has primarily examined whether or not the use of social media endangers or strengthens armed forces’ strategic narrative. We examine armed forces’ perceptions of risks and opportunities on a broad basis, with a particular focus on areas of deployment. The article is based on a survey of perceptions of social media amongst the armed forces of EU member states, thus adding to previous res...

  13. Differences Between Right and Left Arm Blood Pressures in the Elderly

    OpenAIRE

    Hashimoto, Fred; Hunt, William C.; Hardy, Linda

    1984-01-01

    Recommendations vary on whether blood pressures should be measured in the right or in the left arm because no frequency distributions for a pressure difference between the arms exist. We took a total of 12 blood pressure determinations in both arms of 174 elderly persons and analyzed the data by a least-squares components of variance method. The mean difference between the arms (right minus left) was 0.93 mm of mercury for systole and 0.70 mm of mercury for diastole. For systole the proportio...

  14. European Union's Arms Control Regime and Arms Exports to China: Background and Legal Analysis

    National Research Council Canada - National Science Library

    Grimmett, Richard F; Papademetriou, Theresa

    2005-01-01

    In recent months, discussions have been held within the European Union (EU) on the question of lifting the embargo on arms exports to the People's Republic of China that was imposed on China on June 27, 1989...

  15. Virtual Reality Aided Positioning of Mobile C-Arms for Image-Guided Surgery

    Directory of Open Access Journals (Sweden)

    Zhenzhou Shao

    2014-06-01

    Full Text Available For the image-guided surgery, the positioning of mobile C-arms is a key technique to take X-ray images in a desired pose for the confirmation of current surgical outcome. Unfortunately, surgeons and patient often suffer the radiation exposure due to the repeated imaging when the X-ray image is of poor quality or not captured at a good projection view. In this paper, a virtual reality (VR aided positioning method for the mobile C-arm is proposed by the alignment of 3D surface model of region of interest and preoperative anatomy, so that a reference pose of the mobile C-arm with respect to the inside anatomy can be figured out from outside view. It allows a one-time imaging from the outside view to greatly reduce the additional radiation exposure. To control the mobile C-arm to the desired pose, the mobile C-arm is modeled as a robotic arm with a movable base. Experiments were conducted to evaluate the accuracy of appearance model and precision of mobile C-arm positioning. The appearance model was reconstructed with the average error of 2.16 mm. One-time imaging of mobile C-arm was achieved, and new modeling of mobile C-arm with 8 DoFs enlarges the working space in the operating room.

  16. Hand-Arm vibration assessment among tiller operator

    Directory of Open Access Journals (Sweden)

    P. Nassiri

    2013-08-01

    Result: Results of the present study indicated that in all measured situations, exposure to hand arm vibration was higher than the standard limit suggested by Iranian occupational health committee and there was risk of vibration-induced disorders. The maximum exposure to vibration is in plowing ground. Exposure to hand arm vibration in three modes of plowing, transmission and natural, were respectively 16.95, 14.16 and 8.65 meters per second squared. Additionally, in all situations, vibration exposure was highest in the X-axis in comparison with Z- and Y-axes. .Conclusion: This study emphasizes on the need to provide intervention and controlling and managing strategies in order to eliminate or reduce vibration transmitted from tiller to operators hand and arm and also prevent to serious problems including neurovascular disorders, discomfort and white finger syndrome. Meanwhile, more studies are necessary to identify the sources of vibration on different models of tiller.

  17. Synthesis of Mikto-Arm Star Peptide Conjugates.

    Science.gov (United States)

    Koo, Jin Mo; Su, Hao; Lin, Yi-An; Cui, Honggang

    2018-01-01

    Mikto-arm star peptide conjugates are an emerging class of self-assembling peptide-based structural units that contain three or more auxiliary segments of different chemical compositions and/or functionalities. This group of molecules exhibit interesting self-assembly behavior in solution due to their chemically asymmetric topology. Here we describe the detailed procedure for synthesis of an ABC Mikto-arm star peptide conjugate in which two immiscible entities (a saturated hydrocarbon and a hydrophobic and lipophobic fluorocarbon) are conjugated onto a short β-sheet forming peptide sequence, GNNQQNY, derived from the Sup35 prion, through a lysine junction. Automated and manual Fmoc-solid phase synthesis techniques are used to synthesize the Mikto-arm star peptide conjugates, followed by HPLC purification. We envision that this set of protocols can afford a versatile platform to synthesize a new class of peptidic building units for diverse applications.

  18. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  19. A Unified Approach for Reporting ARM Measurement Uncertainties Technical Report: Updated in 2016

    Energy Technology Data Exchange (ETDEWEB)

    Sisterson, Douglas [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-01-15

    The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility is observationally based, and quantifying the uncertainty of its measurements is critically important. With over 300 widely differing instruments providing over 2,500 datastreams, concise expression of measurement uncertainty is quite challenging. ARM currently provides data and supporting metadata (information about the data or data quality) to its users through several sources. Because the continued success of the ARM Facility depends on the known quality of its measurements, ARM relies on Instrument Mentors and the ARM Data Quality Office to ensure, assess, and report measurement quality. Therefore, an easily accessible, well-articulated estimate of ARM measurement uncertainty is needed. This report is a continuation of the work presented by Campos and Sisterson (2015) and provides additional uncertainty information from instruments not available in their report. As before, a total measurement uncertainty has been calculated as a function of the instrument uncertainty (calibration factors), the field uncertainty (environmental factors), and the retrieval uncertainty (algorithm factors). This study will not expand on methods for computing these uncertainties. As before, it will focus on the practical identification, characterization, and inventory of the measurement uncertainties already available to the ARM community through the ARM Instrument Mentors and their ARM instrument handbooks. This study continues the first steps towards reporting ARM measurement uncertainty as: (1) identifying how the uncertainty of individual ARM measurements is currently expressed, (2) identifying a consistent approach to measurement uncertainty, and then (3) reclassifying ARM instrument measurement uncertainties in a common framework.

  20. Worldwide Report, Arms Control.

    Science.gov (United States)

    1986-02-04

    8217Unpredictable Consequences’ of SDI (Moscow PRAVDA, 7 Dec 85) 22 Moscow TV on ASTEC Meeting, Military Monopolies, SDI (Tomas Kolesnichenko; Moscow...planet. /8309 CSO: 5200/1228 22 JPRS-TAO86*014 4 February 1986 SDI AND SPACE ARMS MOSCOW TV ON ASTEC MEETING, MILITARY MONOPOLIES, SDI

  1. Feasibility of a Short-Arm Centrifuge for Mouse Hypergravity Experiments.

    Directory of Open Access Journals (Sweden)

    Hironobu Morita

    Full Text Available To elucidate the pure impact of microgravity on small mammals despite uncontrolled factors that exist in the International Space Station, it is necessary to construct a 1 g environment in space. The Japan Aerospace Exploration Agency has developed a novel mouse habitat cage unit that can be installed in the Cell Biology Experiment Facility in the Kibo module of the International Space Station. The Cell Biology Experiment Facility has a short-arm centrifuge to produce artificial 1 g gravity in space for mouse experiments. However, the gravitational gradient formed inside the rearing cage is larger when the radius of gyration is shorter; this may have some impact on mice. Accordingly, biological responses to hypergravity induced by a short-arm centrifuge were examined and compared with those induced by a long-arm centrifuge. Hypergravity induced a significant Fos expression in the central nervous system, a suppression of body mass growth, an acute and transient reduction in food intake, and impaired vestibulomotor coordination. There was no difference in these responses between mice raised in a short-arm centrifuge and those in a long-arm centrifuge. These results demonstrate the feasibility of using a short-arm centrifuge for mouse experiments.

  2. Armed Helicopters: How the Army Fought Its Way into Attack Aviation

    Science.gov (United States)

    2015-04-01

    arm. It is included as an integral part of armies, corps and divisions; and as such must operate in close liaison with all arms.”5 The observation... launchers machine guns and mini-guns.57 There still seemed to be little if any systematic approach to the armed helicopter concept. The leadership

  3. Collaborative School Innovation Project as a Pivot for Teachers' Professional Development: The Case of Acharnes' Second Chance School in Greece

    Science.gov (United States)

    Katsarou, Eleni; Tsafos, Vassilis

    2008-01-01

    A collaborative school innovation project is explored as a pivot for the professional development of the teachers involved. The Second Chance School (SCS) of Acharnes in Greece constitutes such a collaborative innovative project, regarding the underlying theory of multiliteracies, its decentralised character, respect for student individuality, and…

  4. Worldwide Report, Arms Control

    Science.gov (United States)

    1986-02-28

    NACHRICHTEN , 18 Oct 85) 39 Presummit Polish Reporting on SDI Issues (Warsaw RZECZPOSPOLITA, 19-20 Oct 85; Warsaw ZYCIE WARSZAWY, 15 Oct 85) 42...28 February 1986 SDI AND SPACE ARMS MEETING REVEALS SOME SUPPORT FOR EUREKA LINK TO MILITARY Puesseldbrf VDI NACHRICHTEN in German 18 Oct 85 p 10

  5. Arms Trafficking and Colombia

    Science.gov (United States)

    2003-01-01

    chronology of the intensification of violence in the area, see Noche Y Niebla: Panorama De Derechos Humanos Y Violencia Politica En Colombia, Bogotá...Arms, London, UK: Zed Books, 2000, pp. 155–178. Noche Y Niebla: Panorama De Derechos Humanos Y Violencia Politica En Colombia, Bogotá: Cinep & Justicia

  6. Regenerator cross arm seal assembly

    Science.gov (United States)

    Jackman, Anthony V.

    1988-01-01

    A seal assembly for disposition between a cross arm on a gas turbine engine block and a regenerator disc, the seal assembly including a platform coextensive with the cross arm, a seal and wear layer sealingly and slidingly engaging the regenerator disc, a porous and compliant support layer between the platform and the seal and wear layer porous enough to permit flow of cooling air therethrough and compliant to accommodate relative thermal growth and distortion, a dike between the seal and wear layer and the platform for preventing cross flow through the support layer between engine exhaust and pressurized air passages, and air diversion passages for directing unregenerated pressurized air through the support layer to cool the seal and wear layer and then back into the flow of regenerated pressurized air.

  7. The Accountability of Armed Groups under Human Rights Law

    NARCIS (Netherlands)

    Fortin, K.M.A.

    2015-01-01

    The starting point for this NWOI funded Ph.D. research is the observation that although UN accountability mechanisms are increasingly holding armed groups ‘accountable’ under human rights law, the legal basis for the responsibility of armed groups under human rights law remains controversial

  8. Inverse kinematics of OWI-535 robotic arm

    OpenAIRE

    DEBENEC, PRIMOŽ

    2015-01-01

    The thesis aims to calculate the inverse kinematics for the OWI-535 robotic arm. The calculation of the inverse kinematics determines the joint parameters that provide the right pose of the end effector. The pose consists of the position and orientation, however, we will focus only on the second one. Due to arm limitations, we have created our own type of the calculation of the inverse kinematics. At first we have derived it only theoretically, and then we have transferred the derivation into...

  9. Animals and the law of armed conflict

    OpenAIRE

    Roscini, M.

    2017-01-01

    The main purposes of this article are to assess whether the existing rules of the law of armed conflict provide adequate protection to animals and to highlight the fault lines in the law. The article distinguishes the general provisions of the law of armed conflict, i.e. those that were not adopted with specific regard to animals but the application of which might restrict the killing and injuring of animals, from the provisions that specifically provide protection to animals. The analysis es...

  10. Effect of pivotal response treatment on social skill of 6-11 years old autistic children of Hamedan

    Directory of Open Access Journals (Sweden)

    Fereshteh Mohammad Zaheri

    2013-05-01

    Full Text Available Introduction: Autism is a lifetime developmental disability that determines with sever problem in social relations, communication and behavior. Regarding social interaction difficulties of these children and weakness of social skill interventions in creation of motivation. In this study we tried to examine effect pivotal response treatment method on social skill of autistic children.Material & Methods: In this randomized control trial (RCT study, according to inclusion and exclusion criteria, 30 autistic participants (6 to 11 years old that matched based on age, gender and mean length utterance, from especial clinics of Hamedan’s autistic persons selected and placed randomly in one of groups of intervention and control. Sessions was administered individually, lasting for 60 minutes and 2 days a week for 3 months. Both groups of children were tested before and after intervention by CCC (children’s communication checklist to assess social skill. Data analysis was done through descriptive statistics tests and covariance analysis.Results: Findings of study showed (according to covariance analysis between before and after of intervention in two groups there is significant changes in social skill’s ability in intervention group.Conclusion: The result of these study indicated effect of pivotal response treatment on social skills in autistic children, therefore this method recommended for speech and language pathologist.

  11. Apparatus for installing and removing a control rod drive in a nuclear reactor

    International Nuclear Information System (INIS)

    Turner, A.P.L.; Ward, R.

    1989-01-01

    This patent describes an apparatus for installing and removing a control rod drive from beneath the pressure vessel of a nuclear reactor. It consists of elevator carriage for carrying the control rod drive into and out of the region beneath the pressure vessel in a generally horizontal position, an elevator cradle mounted on the carriage for pivotal movement about an axis between horizontal and vertical positions and for vertical movement, when in the vertical position, means for securing the control rod drive to the elevator cradle, and a winch cart movable horizontally between a first position spaced from the pivot axis and a second position near the pivot axis. The cart has a winch cable supporting the lower end of the elevator carriage for moving the elevator carriage and the control rod drive between horizontal and vertical positions on the elevator carriage when the cart is spaced from the pivot axis and for raising and lowering the elevator cradle and the control rod drive when the cart is positioned near the pivot axis. The control rod drive is mounted on the elevator cradle by a bearing permitting rotational and horizontal movement of the control rod drive when the drive is in a vertical position, a swing arm, a pneumatically actuated cylinder in axial alignment with the control rod drive for raising and lowering the control rod drive, and means pivotally mounting the cylinder on the swing arm for movement about an axis spaced from and generally parallel to the vertically extending axis so that the position of the cylinder and the control rod drive can be shifted horizontally about the vertically extending axes

  12. Unequal arm space-borne gravitational wave detectors

    International Nuclear Information System (INIS)

    Larson, Shane L.; Hellings, Ronald W.; Hiscock, William A.

    2002-01-01

    Unlike ground-based interferometric gravitational wave detectors, large space-based systems will not be rigid structures. When the end stations of the laser interferometer are freely flying spacecraft, the armlengths will change due to variations in the spacecraft positions along their orbital trajectories, so the precise equality of the arms that is required in a laboratory interferometer to cancel laser phase noise is not possible. However, using a method discovered by Tinto and Armstrong, a signal can be constructed in which laser phase noise exactly cancels out, even in an unequal arm interferometer. We examine the case where the ratio of the armlengths is a variable parameter, and compute the averaged gravitational wave transfer function as a function of that parameter. Example sensitivity curve calculations are presented for the expected design parameters of the proposed LISA interferometer, comparing it to a similar instrument with one arm shortened by a factor of 100, showing how the ratio of the armlengths will affect the overall sensitivity of the instrument

  13. Processing ARM VAP data on an AWS cluster

    Science.gov (United States)

    Martin, T.; Macduff, M.; Shippert, T.

    2017-12-01

    The Atmospheric Radiation Measurement (ARM) Data Management Facility (DMF) manages over 18,000 processes and 1.3 TB of data each day. This includes many Value Added Products (VAPs) that make use of multiple instruments to produce the derived products that are scientifically relevant. A thermodynamic and cloud profile VAP is being developed to provide input to the ARM Large-eddy simulation (LES) ARM Symbiotic Simulation and Observation (LASSO) project (https://www.arm.gov/capabilities/vaps/lasso-122) . This algorithm is CPU intensive and the processing requirements exceeded the available DMF computing capacity. Amazon Web Service (AWS) along with CfnCluster was investigated to see how it would perform. This cluster environment is cost effective and scales dynamically based on demand. We were able to take advantage of autoscaling which allowed the cluster to grow and shrink based on the size of the processing queue. We also were able to take advantage of the Amazon Web Services spot market to further reduce the cost. Our test was very successful and found that cloud resources can be used to efficiently and effectively process time series data. This poster will present the resources and methodology used to successfully run the algorithm.

  14. 76 FR 17111 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-03-28

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 11-10] 36(b)(1) Arms Sales Notification AGENCY: Department of Defense, Defense Security Cooperation Agency. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  15. 76 FR 37071 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-06-24

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-03] 36(b)(1) Arms Sales Notification AGENCY: Department of Defense, Defense Security Cooperation Agency. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  16. 76 FR 37075 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-06-24

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-77] 36(b)(1) Arms Sales Notification AGENCY: Department of Defense, Defense Security Cooperation Agency. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  17. 76 FR 43659 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-07-21

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 11-28] 36(b)(1) Arms Sales Notification AGENCY: Department of Defense, Defense Security Cooperation Agency. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  18. 76 FR 27026 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-05-10

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 11-13] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, Department of Defense. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  19. 76 FR 37078 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-06-24

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-68] 36(b)(1) Arms Sales Notification AGENCY: Department of Defense, Defense Security Cooperation Agency. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  20. 77 FR 60384 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-10-03

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-54] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This is...

  1. 76 FR 29212 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-05-20

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-75] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, Department of Defense. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  2. 75 FR 76418 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-12-08

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-65] 36(b)(1) Arms Sales Notification AGENCY: Department of Defense, Defense Security Cooperation Agency. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  3. 75 FR 76415 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-12-08

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-72] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, Department of Defense. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  4. 75 FR 74011 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-11-30

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-24] 36(b)(1) Arms Sales Notification AGENCY: Department of Defense, Defense Security Cooperation Agency. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  5. 75 FR 76412 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-12-08

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-69] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, Department of Defense. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  6. 77 FR 60391 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-10-03

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-32] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This is...

  7. 75 FR 74014 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-11-30

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-49] 36(b)(1) Arms Sales Notification AGENCY: Department of Defense, Defense Security Cooperation Agency. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  8. 76 FR 27022 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-05-10

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 11-12] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, Department of Defense. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  9. 77 FR 60387 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-10-03

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-26] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This is...

  10. 75 FR 76408 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-12-08

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-73] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, Department of Defense. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  11. Affine pairings on ARM

    NARCIS (Netherlands)

    Acar, T.; Lauter, K.; Naehrig, M.; Shumow, D.; Abdalla, M.; Lange, T.

    2013-01-01

    We report on relative performance numbers for affine and projective pairings on a dual-core Cortex A9 ARM processor. Using a fast inversion in the base field and doing inversion in extension fields by using the norm map to reduce to inversions in smaller fields, we find a very low ratio of

  12. Science Plan for the Atmospheric Radiation Measurement Program (ARM)

    International Nuclear Information System (INIS)

    1996-02-01

    The purpose of this Atmospheric Radiation Measurement (ARM) Science Plan is to articulate the scientific issues driving the ARM Program, and to relate them to DOE's programmatic objectives for ARM, based on the experience and scientific progress gained over the past five years. ARM programmatic objectives are to: (1) Relate observed radiative fluxes and radiances in the atmosphere, spectrally resolved and as a function of position and time, to the temperature and composition of the atmosphere, specifically including water vapor and clouds, and to surface properties, and sample sufficient variety of situations so as to span a wide range of climatologically relevant possibilities; (2) develop and test parameterizations that can be used to accurately predict the radiative properties and to model the radiative interactions involving water vapor and clouds within the atmosphere, with the objective of incorporating these parameterizations into general circulation models. The primary observational methods remote sending and other observations at the surface, particularly remote sensing of clouds, water vapor and aerosols

  13. Maximizing Use of Robot-Arm No. 3 in Da Vinci–Assisted Thoracic Surgery

    Science.gov (United States)

    Kajiwara, Naohiro; Maeda, Junichi; Yoshida, Koichi; Kato, Yasufumi; Hagiwara, Masaru; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2015-01-01

    We have previously reported on the importance of appropriate robot-arm settings and replacement of instrument ports in robot-assisted thoracic surgery, because the thoracic cavity requires a large space to access all lesions in various areas of the thoracic cavity from the apex to the diaphragm and mediastinum and the chest wall.1–3 Moreover, it can be difficult to manipulate the da Vinci Surgical System using only arms No. 1 and No. 2 depending on the tumor location. However, arm No. 3 is usually positioned on the same side as arm No. 2, and sometimes it is only used as an assisting-arm to avoid conflict with other arms (Fig. 1). In this report, we show how robot-arm No. 3 can be used with maximum effectiveness in da Vinci-assisted thoracic surgery. PMID:26011219

  14. Swiss Armed Forces Reform: Doctrinal and Organizational Challenges

    Science.gov (United States)

    2016-06-10

    conservatism and military innovation since this is where the essence of the Armed Forces resides. Sound doctrine and coherent organizations enables the...established doctrine can become part of the conservatism of the military institution. So the innovative capabilities of the military organization affect...in other fields. They challenged the inherent conservatism of the military institution. The down-sizing of the Armed Forces, the reduction of

  15. One arm exercise induces significant interarm diastolic blood pressure difference.

    Science.gov (United States)

    Hong, Dezhi; Wang, Jiwei; Su, Hai; Xu, Jingsong; Liu, Yanna; Peng, Qiang; Wang, Lijuan

    2011-06-01

    This study is designed to investigate the inducing effect of one arm exercise on interarm difference (IAD) in the blood pressure (BP). Fifty healthy young participants were included in the study. Three-minute exercises of the right arm elbow flexion and extension were performed. The bilateral brachial BP was simultaneously measured with two automatic BP measurement devices before (basic) and immediately 0, 5, 10, 15, 20, and 30 min after exercise. The absolute difference in the systolic BP (SBP) and diastolic BP (DBP) between the left and right BP of at least 10 mmHg was recognized as sIAD and dIAD. The baseline data of the SBP and DBP in left and right arms revealed no significant difference (SBP: 110 ± 10 vs. 111 ± 11 mmHg; DBP: 66 ± 8 vs. 66 ± 9 mmHg, both not significant). The prevalence of dIAD was 2% at the baseline. However, this prevalence increased to 80% at 0 min, as right arm exercise induced the right DBP decrease and left DBP increase, and then the prevalence decreased gradually within a 30-min recovery period. The prevalence of sIAD was zero at the baseline and the maximal prevalence was 8% during the 20-min postexercise period. One arm exercise can lead to a significant IAD in DBP. Any arm exercise should be avoided before BP measurement.

  16. Localization of age-related macular degeneration-associated ARMS2 in cytosol, not mitochondria

    Science.gov (United States)

    Wang, Gaofeng; Spencer, Kylee L.; Court, Brenda L.; Olson, Lana M.; Scott, William K.; Haines, Jonathan L.; Pericak-Vance, Margaret A.

    2010-01-01

    PURPOSE To analyze the relationship between ARMS2 and HTRA1 in the association with age-related macular degeneration (AMD) in an independent case-control dataset, and to investigate the subcellular localization of the ARMS2 protein in an in vitro system. METHOD Two SNPs in ARMS2 and HTRA1 were genotyped in 685 cases and 269 controls by Taqman Assay. Allelic association was tested by a χ2 test. A likelihood ratio test (LRT) of full vs. reduced models was utilized to analyze the interaction between ARMS2 and smoking and HTRA1 and smoking, after adjusting for CFH and age. Immunofluorescence and immunoblot were applied to localize ARMS2 in retinal epithelial ARPE-19 cells and COS7 cell transfected by ARMS2 constructs. RESULT Both significantly associated SNP rs10490924 and rs11200638 (P<0.0001) are in strong linkage disequilibrium (LD) (D′=0.97, r2=0.93) that generates virtually identical association test and odds ratios. In separate logistic regression models the interaction effect for both smoking with ARMS2 and with HTRA1 was not statistically significant. Immunofluorescence and immunoblot show that both endogenous and exogenous ARMS2 are mainly distributed in the cytosol, not the mitochondria. Comparing to wild type, ARMS2 A69S is more likely to be associated with cytoskeleton in COS7 cells. CONCLUSIONS The significant associations in ARMS2 and HTRA1 are with polymorphisms in strong LD that confer virtually identical risks, preventing differentiation at the statistical level. We found that ARMS2 was mainly distributed in the cytosol, not in mitochondrial outer membrane as previously reported, suggesting that ARMS2 may not confer risk to AMD through the mitochondrial pathway. PMID:19255159

  17. Exact positioning of the robotic arm end effector

    Science.gov (United States)

    Korepanov, Valery; Dudkin, Fedir

    2016-07-01

    Orbital service becomes a new challenge of space exploration. The necessity to introduce it is connected first of all with an attractive opportunity to prolong the exploitation terms of expensive commercial satellites by, e.g., refilling of fuel or changing batteries. Other application area is a fight with permanently increasing amount of space litter - defunct satellites, burnt-out rocket stages, discarded trash and other debris. Now more than few tens of thousands orbiting objects larger than 5-10 cm (or about 1 million junks larger than 1 cm) are a huge problem for crucial and costly satellites and manned vehicles. For example, in 2014 the International Space Station had to change three times its orbit to avoid collision with space debris. So the development of the concepts and actions related to removal of space debris or non-operational satellites with use of robotic arm of a servicing satellite is very actual. Such a technology is also applicable for unmanned exploratory missions in solar system, for example for collecting a variety of samples from a celestial body surface. Naturally, the robotic arm movements should be controlled with great accuracy at influence of its non-rigidity, thermal and other factors. In these circumstances often the position of the arm end effector has to be controlled with high accuracy. The possibility of coordinate determination for the robotic arm end effector with use of a low frequency active electromagnetic system has been considered in the presented report. The proposed design of such a system consists of a small magnetic dipole source, which is mounted inside of the arm end effector and two or three 3-component magnetic field sensors mounted on a servicing satellite body. The data from this set of 3-component magnetic field sensors, which are fixed relatively to the satellite body, allows use of the mathematical approach for determination of position and orientation of the magnetic dipole source. The theoretical

  18. Arms Transfer and Confl ict in Africa The Role of China in Sudan ...

    African Journals Online (AJOL)

    The central argument of this article is that arms transfers from countries such as China to Sudan help sustain the armed confl ict in the country, as well as in the Horn of Africa region. This is because arms transfer increases the risk of ethnic disharmony, deeper militarisation, increased crime rate, multiplication of armed ...

  19. Pivot/Remote: a distributed database for remote data entry in multi-center clinical trials.

    Science.gov (United States)

    Higgins, S B; Jiang, K; Plummer, W D; Edens, T R; Stroud, M J; Swindell, B B; Wheeler, A P; Bernard, G R

    1995-01-01

    1. INTRODUCTION. Data collection is a critical component of multi-center clinical trials. Clinical trials conducted in intensive care units (ICU) are even more difficult because the acute nature of illnesses in ICU settings requires that masses of data be collected in a short time. More than a thousand data points are routinely collected for each study patient. The majority of clinical trials are still "paper-based," even if a remote data entry (RDE) system is utilized. The typical RDE system consists of a computer housed in the CC office and connected by modem to a centralized data coordinating center (DCC). Study data must first be recorded on a paper case report form (CRF), transcribed into the RDE system, and transmitted to the DCC. This approach requires additional monitoring since both the paper CRF and study database must be verified. The paper-based RDE system cannot take full advantage of automatic data checking routines. Much of the effort (and expense) of a clinical trial is ensuring that study data matches the original patient data. 2. METHODS. We have developed an RDE system, Pivot/Remote, that eliminates the need for paper-based CRFs. It creates an innovative, distributed database. The database resides partially at the study clinical centers (CC) and at the DCC. Pivot/Remote is descended from technology introduced with Pivot [1]. Study data is collected at the bedside with laptop computers. A graphical user interface (GUI) allows the display of electronic CRFs that closely mimic the normal paper-based forms. Data entry time is the same as for paper CRFs. Pull-down menus, displaying the possible responses, simplify the process of entering data. Edit checks are performed on most data items. For example, entered dates must conform to some temporal logic imposed by the study. Data must conform to some acceptable range of values. Calculations, such as computing the subject's age or the APACHE II score, are automatically made as the data is entered. Data

  20. Feasibility Analysis of an All Volunteer Armed Force in Turkey

    National Research Council Canada - National Science Library

    Alanc, Ozgun U

    2007-01-01

    .... Accordingly, this project report provides a Draft versus All Volunteer Forces (AVF) analysis for the Turkish Armed Forces, by evaluating the feasibility and the desirability of an AVF for the Turkish Armed Forces...

  1. 75 FR 60424 - 36(b)(1) Arms Sales Notifications

    Science.gov (United States)

    2010-09-30

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-28 and 10-30] 36(b)(1) Arms Sales Notifications AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of two section 36(b)(1) arms sales notifications to...

  2. 75 FR 29998 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-05-28

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal No. 10-22] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification to fulfill the...

  3. 75 FR 23247 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-05-03

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal No. 10-08] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification to fulfill the...

  4. 75 FR 27314 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-05-14

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal No. 10-19] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification to fulfill the...

  5. 75 FR 11865 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-03-12

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal No. 10-12] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification to fulfill the...

  6. 76 FR 60455 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-09-29

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-71] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... support. (iv) Military Department: Army (UJT). (v) Prior Related Cases, if any: None. (vi) Sales...

  7. 77 FR 12037 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-02-28

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-11] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... support. (iv) Military Department: Navy (SAF). (v) Prior Related Cases, if any: None. (vi) Sales...

  8. The position of the arm during blood pressure measurement in sitting position.

    NARCIS (Netherlands)

    Adiyaman, A.; Verhoeff, R.; Lenders, J.W.M.; Deinum, J.; Thien, Th.

    2006-01-01

    OBJECTIVE: Determining the influence of the position of the arm on blood pressure measurement in the sitting position. METHODS: Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in

  9. Targeting and killing of glioblastoma with activated T cells armed with bispecific antibodies

    International Nuclear Information System (INIS)

    Zitron, Ian M; Thakur, Archana; Norkina, Oxana; Barger, Geoffrey R; Lum, Lawrence G; Mittal, Sandeep

    2013-01-01

    Since most glioblastomas express both wild-type EGFR and EGFRvIII as well as HER2/neu, they are excellent targets for activated T cells (ATC) armed with bispecific antibodies (BiAbs) that target EGFR and HER2. ATC were generated from PBMC activated for 14 days with anti-CD3 monoclonal antibody in the presence of interleukin-2 and armed with chemically heteroconjugated anti-CD3×anti-HER2/neu (HER2Bi) and/or anti-CD3×anti-EGFR (EGFRBi). HER2Bi- and/or EGFRBi-armed ATC were examined for in vitro cytotoxicity using MTT and 51 Cr-release assays against malignant glioma lines (U87MG, U118MG, and U251MG) and primary glioblastoma lines. EGFRBi-armed ATC killed up to 85% of U87, U118, and U251 targets at effector:target ratios (E:T) ranging from 1:1 to 25:1. Engagement of tumor by EGFRBi-armed ATC induced Th1 and Th2 cytokine secretion by armed ATC. HER2Bi-armed ATC exhibited comparable cytotoxicity against U118 and U251, but did not kill HER2-negative U87 cells. HER2Bi- or EGFRBi-armed ATC exhibited 50—80% cytotoxicity against four primary glioblastoma lines as well as a temozolomide (TMZ)-resistant variant of U251. Both CD133– and CD133+ subpopulations were killed by armed ATC. Targeting both HER2Bi and EGFRBi simultaneously showed enhanced efficacy than arming with a single BiAb. Armed ATC maintained effectiveness after irradiation and in the presence of TMZ at a therapeutic concentration and were capable of killing multiple targets. High-grade gliomas are suitable for specific targeting by armed ATC. These data, together with additional animal studies, may provide the preclinical support for the use of armed ATC as a valuable addition to current treatment regimens

  10. Naval trends in ASEAN: is there a new arms race?

    OpenAIRE

    Jones, Frank Curtis

    1995-01-01

    Global military spending is decreasing. However this trend does not apply to some regions of the world, specifically Southeast Asia. This thesis describes the ongoing naval arms buildup in this region and examines why it is occurring when the rest of the world is decreasing military spending. Next, this thesis asks if this arms build-up is dangerous. Unlike many other arms races around the world, the Southeast Asian build-up is not particularly dangerous because of the parallel development of...

  11. Patterns of motor activity in the isolated nerve cord of the octopus arm.

    Science.gov (United States)

    Gutfreund, Yoram; Matzner, Henry; Flash, Tamar; Hochner, Binyamin

    2006-12-01

    The extremely flexible octopus arm provides a unique opportunity for studying movement control in a highly redundant motor system. We describe a novel preparation that allows analysis of the peripheral nervous system of the octopus arm and its interaction with the muscular and mechanosensory elements of the arm's intrinsic muscular system. First we examined the synaptic responses in muscle fibers to identify the motor pathways from the axial nerve cord of the arm to the surrounding musculature. We show that the motor axons project to the muscles via nerve roots originating laterally from the arm nerve cord. The motor field of each nerve is limited to the region where the nerve enters the arm musculature. The same roots also carry afferent mechanosensory information from the intrinsic muscle to the axial nerve cord. Next, we characterized the pattern of activity generated in the dorsal roots by electrically stimulating the axial nerve cord. The evoked activity, although far reaching and long lasting, cannot alone account for the arm extension movements generated by similar electrical stimulation. The mismatch between patterns of activity in the isolated cord and in an intact arm may stem from the involvement of mechanosensory feedback in natural arm extension.

  12. Stereotypical reaching movements of the octopus involve both bend propagation and arm elongation.

    Science.gov (United States)

    Hanassy, S; Botvinnik, A; Flash, T; Hochner, B

    2015-05-13

    The bend propagation involved in the stereotypical reaching movement of the octopus arm has been extensively studied. While these studies have analyzed the kinematics of bend propagation along the arm during its extension, possible length changes have been ignored. Here, the elongation profiles of the reaching movements of Octopus vulgaris were assessed using three-dimensional reconstructions. The analysis revealed that, in addition to bend propagation, arm extension movements involve elongation of the proximal part of the arm, i.e., the section from the base of the arm to the propagating bend. The elongations are quite substantial and highly variable, ranging from an average strain along the arm of -0.12 (i.e. shortening) up to 1.8 at the end of the movement (0.57 ± 0.41, n = 64 movements, four animals). Less variability was discovered in an additional set of experiments on reaching movements (0.64 ± 0.28, n = 30 movements, two animals), where target and octopus positions were kept more stationary. Visual observation and subsequent kinematic analysis suggest that the reaching movements can be broadly segregated into two groups. The first group involves bend propagation beginning at the base of the arm and propagating towards the arm tip. In the second, the bend is formed or present more distally and reaching is achieved mainly by elongation and straightening of the segment proximal to the bend. Only in the second type of movements is elongation significantly positively correlated with the distance of the bend from the target. We suggest that reaching towards a target is generated by a combination of both propagation of a bend along the arm and arm elongation. These two motor primitives may be combined to create a broad spectrum of reaching movements. The dynamical model, which recapitulates the biomechanics of the octopus muscular hydrostatic arm, suggests that achieving the observed elongation requires an extremely low ratio of longitudinal to transverse muscle

  13. The effect of unilateral arm swing motion on lower extremity running mechanics associated with injury risk.

    Science.gov (United States)

    Agresta, Cristine; Ward, Christian R; Wright, W Geoffrey; Tucker, Carole A

    2018-06-01

    Many field sports involve equipment that restricts one or both arms from moving while running. Arm swing during running has been examined from a biomechanical and physiologic perspective but not from an injury perspective. Moreover, only bilateral arm swing suppression has been studied with respect to running. The purpose of this study was to determine the influence of running with one arm restrained on lower extremity mechanics associated with running or sport-related injury. Fifteen healthy participants ran at a self-selected speed with typical arm swing, with one arm restrained and with both arms restrained. Lower extremity kinematics and spatiotemporal measures were analysed for all arm swing conditions. Running with one arm restrained resulted in increased frontal plane knee and hip angles, decreased foot strike angle, and decreased centre of mass vertical displacement compared to typical arm swing or bilateral arm swing restriction. Stride length was decreased and step frequency increased when running with one or both arms restrained. Unilateral arm swing restriction induces changes in lower extremity kinematics that are not similar to running with bilateral arm swing restriction or typical arm swing motion. Running with one arm restrained increases frontal plane mechanics associated with risk of knee injury.

  14. Evaluation of a polymer inclusion membrane containing a C-pivot tripodal diglycolamide for Am(III) extraction

    International Nuclear Information System (INIS)

    Mahanty, B.N.; Das, D.K.; Afzal, Md; Raut, D.R.; Mohapatra, P.K.; Behere, P.G.; Verboom, W.

    2014-01-01

    The instability of supported liquid membrane (SLM), being used for laboratory scale metal ion separation, can be avoided using Polymer inclusion membranes (PIM). We have been carrying out studies on diglycolamide based extractants including a C-pivot tripodal diglycolamide (T-DGA) for actinide ion separation from acidic feed solution. It was thought of interest to study the properties of T-DGA based PIM containing cellulose triacetate (CTA) as polymer and 2-nitrophenyl octyl ether (NPOE) as the plasticizer for Am(III) uptake and transport

  15. The Asteroid Redirect Mission (ARM)

    Science.gov (United States)

    Abell, Paul; Gates, Michele; Johnson, Lindley; Chodas, Paul; Mazanek, Dan; Reeves, David; Ticker, Ronald

    2016-07-01

    To achieve its long-term goal of sending humans to Mars, the National Aeronautics and Space Administration (NASA) plans to proceed in a series of incrementally more complex human spaceflight missions. Today, human flight experience extends only to Low-Earth Orbit (LEO), and should problems arise during a mission, the crew can return to Earth in a matter of minutes to hours. The next logical step for human spaceflight is to gain flight experience in the vicinity of the Moon. These cis-lunar missions provide a "proving ground" for the testing of systems and operations while still accommodating an emergency return path to the Earth that would last only several days. Cis-lunar mission experience will be essential for more ambitious human missions beyond the Earth-Moon system, which will require weeks, months, or even years of transit time. In addition, NASA has been given a Grand Challenge to find all asteroid threats to human populations and know what to do about them. Obtaining knowledge of asteroid physical properties combined with performing technology demonstrations for planetary defense provide much needed information to address the issue of future asteroid impacts on Earth. Hence the combined objectives of human exploration and planetary defense give a rationale for the Asteroid Re-direct Mission (ARM). Mission Description: NASA's ARM consists of two mission segments: 1) the Asteroid Redirect Robotic Mission (ARRM), the first robotic mission to visit a large (greater than ~100 m diameter) near-Earth asteroid (NEA), collect a multi-ton boulder from its surface along with regolith samples, demonstrate a planetary defense technique, and return the asteroidal material to a stable orbit around the Moon; and 2) the Asteroid Redirect Crewed Mission (ARCM), in which astronauts will take the Orion capsule to rendezvous and dock with the robotic vehicle, conduct multiple extravehicular activities to explore the boulder, and return to Earth with samples. NASA's proposed

  16. A Theater Strategy for Northeast Asia, One of the World's Most Critical Regions

    National Research Council Canada - National Science Library

    Willey, Kevin J

    1995-01-01

    .... Uniquely situated among the three major Asian powers, Korea's pivotal geopolitical position has caused three major wars in a short span of 56 years that involved the armed forces of all four major powers2...

  17. 78 FR 62590 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-10-22

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-43] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: None (vii) Sensitivity of...

  18. 76 FR 43662 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-07-21

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 11-15] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...) Military Department: Navy (AAR) (v) Prior Related Cases, if any: None (vi) Sales Commission, Fee, etc...

  19. 75 FR 61440 - 36(b)(1) Arms Sales Notifications

    Science.gov (United States)

    2010-10-05

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-47, 10-48, and 10-51] 36(b)(1) Arms Sales Notifications AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of three section 36(b)(1) arms sales notifications...

  20. 77 FR 37884 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-06-25

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-19] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... Department: Navy (LAN). (v) Prior Related Cases, if any: None. (vi) Sales Commission, Fee, etc., Paid...

  1. 78 FR 26324 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-05-06

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-20] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... Gasoline). (v) Prior Related Cases, if any: Numerous cases dating back to 1995. (vi) Sales Commission, Fee...

  2. 75 FR 48646 - 36(b)(1) Arms Sales Notifications

    Science.gov (United States)

    2010-08-11

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-27, 10-31 and 10-41] 36(b)(1) Arms Sales Notifications AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of three section 36(b)(1) arms sales notifications...

  3. 78 FR 76114 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-12-16

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-66] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: None (vii) Sensitivity of Technology...

  4. 78 FR 42051 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-07-15

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-26] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... any: None (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: None (vii...

  5. 78 FR 62600 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-10-22

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-47] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...: None (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed To Be Paid: None (vii) Sensitivity of...

  6. 77 FR 51780 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-08-27

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-42] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... support. (iv) Military Department: Air Force (QAZ). (v) Prior Related Cases, if any: None. (vi) Sales...

  7. 77 FR 70151 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-11-23

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-56] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...: Army (UAK). (v) Prior Related Cases, if any: None. (vi) Sales Commission, Fee, etc., Paid, Offered, or...

  8. 77 FR 13564 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-03-07

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 11-53] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This..., if any: None (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: None (vii...

  9. 78 FR 62588 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-10-22

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-53] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: None (vii) Sensitivity of Technology...

  10. 75 FR 41820 - 36(b)(1) Arms Sales Notifications

    Science.gov (United States)

    2010-07-19

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-05, 10-11, 10-18, 10-21 and 10-29] 36(b)(1) Arms Sales Notifications AGENCY: Defense Security Cooperation Agency, DoD. ACTION...) arms sales notifications to fulfill the requirements of section 155 of Public Law 104-164, dated 21...

  11. 76 FR 60467 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-09-29

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 11-34] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...: a Foreign Military Sales Order II (FMSO II) to provide funds for blanket order requisitions, under...

  12. 78 FR 69073 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-11-18

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-59] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...) Military Department: Air Force (QAH) (v) Prior Related Cases: None (vi) Sales Commission, Fee, etc., Paid...

  13. Rosoboroneksport: Arms Sales and the Structure of Russian Defense Industry

    National Research Council Canada - National Science Library

    Blank, Stephen J

    2007-01-01

    .... Arms sales thus have become the main source of its revenue until the present and will play a key role in Russia's ongoing attempt to regenerate its armed forces while winning friends and influence abroad...

  14. Arm circumference: its importance for dialysis patients in the obesity era.

    Science.gov (United States)

    Akpolat, Tekin; Kaya, Coşkun; Utaş, Cengiz; Arinsoy, Turgay; Taşkapan, Hülya; Erdem, Emre; Yilmaz, M Emin; Ataman, Rezzan; Bozfakioğlu, Semra; Özener, Çetin; Karayaylali, Ibrahim; Kazancioğlu, Rümeyza; Çamsari, Taner; Yavuz, Mahmut; Ersoy, Fevzi; Duman, Soner; Ateş, Kenan

    2013-08-01

    The purposes of this study were to investigate the association between arm circumference and body mass index (BMI) and to discuss problems, mainly arm circumference and cuff size mismatch, that could affect the reliability of home blood pressure monitoring (HBPM) among peritoneal dialysis (PD) and hemodialysis (HD) patients. 525 PD and 502 HD patients from 16 centers were included in the study. A two-part questionnaire was used to gather information from the participants. Arm circumferences were categorized into four groups according to the British Hypertension Society cuff size recommendations. Mean BMI and arm circumference of all participants were 25.0 kg/m(2) and 27.6 cm, respectively. There was a significant correlation between BMI and arm circumference. The mean BMI and arm circumference values were higher in PD patients than in HD patients. Requirement of a large-sized adult cuff was more common among PD patients compared to HD patients (14 % vs 8 %, p = 0.002). Since HBPM is a useful tool for clinicians to improve BP control, nephrologists should be aware of the problems related to HBPM in dialysis patients and take an active role to increase the reliability of HBPM.

  15. Increasing cognitive load attenuates right arm swing in healthy human walking

    Science.gov (United States)

    Killeen, Tim; Easthope, Christopher S.; Filli, Linard; Lőrincz, Lilla; Schrafl-Altermatt, Miriam; Brugger, Peter; Linnebank, Michael; Curt, Armin; Zörner, Björn; Bolliger, Marc

    2017-01-01

    Human arm swing looks and feels highly automated, yet it is increasingly apparent that higher centres, including the cortex, are involved in many aspects of locomotor control. The addition of a cognitive task increases arm swing asymmetry during walking, but the characteristics and mechanism of this asymmetry are unclear. We hypothesized that this effect is lateralized and a Stroop word-colour naming task-primarily involving left hemisphere structures-would reduce right arm swing only. We recorded gait in 83 healthy subjects aged 18-80 walking normally on a treadmill and while performing a congruent and incongruent Stroop task. The primary measure of arm swing asymmetry-an index based on both three-dimensional wrist trajectories in which positive values indicate proportionally smaller movements on the right-increased significantly under dual-task conditions in those aged 40-59 and further still in the over-60s, driven by reduced right arm flexion. Right arm swing attenuation appears to be the norm in humans performing a locomotor-cognitive dual-task, confirming a prominent role of the brain in locomotor behaviour. Women under 60 are surprisingly resistant to this effect, revealing unexpected gender differences atop the hierarchical chain of locomotor control.

  16. Study on the Orion spiral arm structure by the statistical modelling method

    International Nuclear Information System (INIS)

    Basharina, T.S.; Pavlovskaya, E.D.; Filippova, A.A.

    1980-01-01

    A method of investigation of the spiral structure based on the statistical modelling methods is suggested. This method is used for the study of the Orion spiral arm. The maxima of density and the widths of the Orion arm in the direction of the areas considered for the longitude interval 55 deg - 187 deg are defined under the assumption of normal distribution of stars across the arm. The Sun is shown to be at the inner edge of the arm [ru

  17. Gender Integration and the Swedish Armed Forces

    DEFF Research Database (Denmark)

    Gustafsson, Daniel Marcus Sunil

    This paper discusses different gender aspects of the Swedish Armed Forces with specific references to sexual harassment and prostitution. By using the concept of Hegemonic Masculinity, sexual harassment of the women in the Swedish Armed Forces is explained in terms of a need of the men within...... the organisation to reinforce the notion of women as inferior and subordinate to men, whereby the external hegemony is believed to be restored. Likewise, male Swedish peacekeepers’ demand for prostitution during international peacekeeping missions is explained in terms of a need to confirm manhood and as homo...

  18. Neurobiology: motor control of flexible octopus arms.

    Science.gov (United States)

    Sumbre, Germán; Fiorito, Graziano; Flash, Tamar; Hochner, Binyamin

    2005-02-10

    Animals with rigid skeletons can rely on several mechanisms to simplify motor control--for example, they have skeletal joints that reduce the number of variables and degrees of freedom that need to be controlled. Here we show that when the octopus uses one of its long and highly flexible arms to transfer an object from one place to another, it employs a vertebrate-like strategy, temporarily reconfiguring its arm into a stiffened, articulated, quasi-jointed structure. This indicates that an articulated limb may provide an optimal solution for achieving precise, point-to-point movements.

  19. Admittance Control of a Multi-Finger Arm Based on Manipulability of Fingers

    Directory of Open Access Journals (Sweden)

    Jian Huang

    2011-09-01

    Full Text Available In the previous studies, admittance control and impedance control for a finger-arm robot using the manipulability of the finger were studied and methods of realizing the controls have been proposed. In this study, two 3-DOF fingers are attached to the end-effector of a 6-DOF arm to configure a multi-finger arm robot. Based on the previous methods, the authors have proposed an admittance control for a multi-finger arm robot using the manipulability of the fingers in this study. Algorithms of the averaging method and the mini-max method were introduced to establish a manipulability criterion of the two fingers in order to generate a cooperative movement of the arm. Comparison of the admittance controls combined with the top search method and local optimization method for the multi-finger arm robot was made and features of the control methods were also discussed. The stiffness control and damping control were experimentally evaluated to demonstrate the effectiveness of the proposed methods.

  20. Re-usable low density polyethylene arm glove for puerperal ...

    African Journals Online (AJOL)

    Objective: To design a long arm glove that can be used within a puerperal uterus to prevent the health-care worker contracting HIV from an infected patient. The designed long arm glove should be cheap (affordable) and readily available in low resource centres and must have proven sterility assurance and tensile strength ...

  1. 78 FR 78939 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-12-27

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-68] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...-$98M (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: N/A (vii) Sensitivity of...

  2. 77 FR 42709 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-07-20

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-24] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... Cases, if any: None (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: None (vii...

  3. 78 FR 26326 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-05-06

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-09] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...-20Feb08. (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: None. (vii) Sensitivity of...

  4. 76 FR 60459 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-09-29

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 11-19] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...-$280 million-29Nov07. (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: None. (vii...

  5. A POSSIBLE EXTENSION OF THE SCUTUM-CENTAURUS ARM INTO THE OUTER SECOND QUADRANT

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yan; Xu, Ye; Yang, Ji; Li, Fa-Cheng; Du, Xin-Yu; Zhang, Shao-Bo; Zhou, Xin, E-mail: yansun@pmo.ac.cn [Purple Mountain Observatory and Key Laboratory of Radio Astronomy, Chinese Academy of Sciences, Nanjing 210008 (China)

    2015-01-10

    Combining H I data from the Canadian Galactic Plane Survey and CO data from the Milky Way Imaging Scroll Painting project, we have identified a new segment of a spiral arm between Galactocentric radii of 15 and 19 kpc that apparently lies beyond the Outer Arm in the second Galactic quadrant. Over most of its length, the arm is 400-600 pc thick in z. The new arm appears to be the extension of the distant arm recently discovered by Dame and Thaddeus as well as the Scutum-Centaurus Arm into the outer second quadrant. Our current survey identified a total of 72 molecular clouds with masses on the order of 10{sup 2}-10{sup 4} M {sub ☉} that probably lie in the new arm. When all of the available data from the CO molecular clouds are fit, the best-fitting spiral model gives a pitch angle of 9.°3 ± 0.°7.

  6. Arm and leg substrate utilization and muscle adaptation after prolonged low-intensity training

    DEFF Research Database (Denmark)

    Helge, Jørn Wulff

    2010-01-01

    This review will focus on current data where substrate metabolism in arm and leg muscle is investigated and discuss the presence of higher carbohydrate oxidation and lactate release observed during arm compared with leg exercise. Furthermore, a basis for a possible difference in substrate partiti...... at comparable workloads. Finally, the influence and capacity of low-intensity training to influence metabolic fitness in the face of a limited effect on aerobic fitness will be challenged....... partitioning between endogenous and exogenous substrate during arm and leg exercise will be debated. Moreover the review will probe if differences between arm and leg muscle are merely a result of different training status rather than a qualitative difference in limb substrate regulation. Along this line...... the review will address the available studies on low-intensity training performed separately with arm or legs or as whole-body training to evaluate if this leads to different adaptations in arm and leg muscle resulting in different substrate utilization patterns during separate arm or leg exercise...

  7. Apparatus for radiological examination of a subject through a solid angle

    International Nuclear Information System (INIS)

    Grady, J.K.; Rice, D.B.

    1975-01-01

    A framework supporting a radiation source, such as an x-ray tube, and a radiation receptor, such as an x-ray film plate holder, comprises four arms pivotally connected to form a regular parallelogram, a parallel pair of the arms extending outside the parallelogram to pivot points for the radiation source and receptor. The parallelogram is mounted on a rotor whose central axis is parallel to the parallel pair of arms. Two links between another one of the arms and the source and receptor respectively, and parallel to the central axis, hold the axis of the source and receptor aligned on a radiation axis which passes through an isocenter on the central axis as the parallelogram is angularly adjusted in planes parallel to the central axis. The angular adjustment of the parallelogram combined with turning of the parallelogram on the rotor permit the source to radiate through a subject at the isocenter, for example the human heart or brain, from throughout a solid angle while maintaining constant radiological distance between the source and subject and a constant axial alignment of the source and receptor. The radiological magnification may also be kept constant, or the receptor may be adjusted along its axis, in which case a counterweight reciprocating along the transverse arm and connected to the receptor by two cables counterbalances the receptor in all solid angle positions. (auth)

  8. Atmospheric Radiation Measurement Climate Research (ARM)

    Data.gov (United States)

    Federal Laboratory Consortium — With heavily instrumented field sites around the globe, the ARM Climate Research Facility provides the world's most comprehensive outdoor laboratory and data archive...

  9. Application of C-arm computed tomography in cardiology; Kardiale Anwendung der C-Arm-Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Rieber, J. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Innenstadt, Abteilung fuer Kardiologie, Medizinische Poliklinik, Muenchen (Germany); Rohkohl, C. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Lehrstuhl fuer Mustererkennung, Department Informatik, Erlangen (Germany); Siemens AG, Healthcare Sector, Forchheim, Forchheim (Germany); Lauritsch, G. [Siemens AG, Healthcare Sector, Forchheim, Forchheim (Germany); Rittger, H. [Krankenhaus Coburg, Abteilung fuer Kardiologie, Coburg (Germany); Meissner, O. [Siemens AG, Healthcare Sector, Forchheim, Forchheim (Germany); Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2009-09-15

    C-arm computed tomography is currently being introduced into cardiac imaging and offers the potential for three-dimensional imaging of the cardiac anatomy within the interventional environment. This detailed view is necessary to support complex interventional strategies, such as transcutaneous valve replacement, interventional therapy of atrial fibrillation, implantation of biventricular pacemakers and assessment of myocardial perfusion. Currently, the major limitation of this technology is its insufficient temporal resolution which limits the visualization of fast moving parts of the heart. (orig.) [German] Durch die Entwicklung der C-Arm-Computertomographie- (CACT-)Angiographie ist es erstmals moeglich, waehrend einer Herzkatheteruntersuchung eine detaillierte dreidimensionale Darstellung der kardialen Anatomie zu erhalten. Derartige zusaetzliche Informationen koennten die Durchfuehrung der immer komplexer werdenden Strategien der interventionellen Kardiologie wirkungsvoll unterstuetzen. Hierzu zaehlen u. a. der transkutane Klappenersatz, die interventionelle Behandlung von Vorhofflimmern, die Implantation biventrikulaerer Schrittmacher sowie die Beurteilung der Myokardperfusion. Die derzeit groesste Limitation dieser Methode ist die relativ geringe zeitliche Aufloesung, die aufgrund der Bewegung des Herzens die Anwendung dieser Technologie einschraenkt. (orig.)

  10. Two Components of Aversive Memory in Drosophila, Anesthesia-Sensitive and Anesthesia-Resistant Memory, Require Distinct Domains Within the Rgk1 Small GTPase.

    Science.gov (United States)

    Murakami, Satoshi; Minami-Ohtsubo, Maki; Nakato, Ryuichiro; Shirahige, Katsuhiko; Tabata, Tetsuya

    2017-05-31

    Multiple components have been identified that exhibit different stabilities for aversive olfactory memory in Drosophila These components have been defined by behavioral and genetic studies and genes specifically required for a specific component have also been identified. Intermediate-term memory generated after single cycle conditioning is divided into anesthesia-sensitive memory (ASM) and anesthesia-resistant memory (ARM), with the latter being more stable. We determined that the ASM and ARM pathways converged on the Rgk1 small GTPase and that the N-terminal domain-deleted Rgk1 was sufficient for ASM formation, whereas the full-length form was required for ARM formation. Rgk1 is specifically accumulated at the synaptic site of the Kenyon cells (KCs), the intrinsic neurons of the mushroom bodies, which play a pivotal role in olfactory memory formation. A higher than normal Rgk1 level enhanced memory retention, which is consistent with the result that Rgk1 suppressed Rac-dependent memory decay; these findings suggest that rgk1 bolsters ASM via the suppression of forgetting. We propose that Rgk1 plays a pivotal role in the regulation of memory stabilization by serving as a molecular node that resides at KC synapses, where the ASM and ARM pathway may interact. SIGNIFICANCE STATEMENT Memory consists of multiple components. Drosophila olfactory memory serves as a fundamental model with which to investigate the mechanisms that underlie memory formation and has provided genetic and molecular means to identify the components of memory, namely short-term, intermediate-term, and long-term memory, depending on how long the memory lasts. Intermediate memory is further divided into anesthesia-sensitive memory (ASM) and anesthesia-resistant memory (ARM), with the latter being more stable. We have identified a small GTPase in Drosophila , Rgk1, which plays a pivotal role in the regulation of olfactory memory stability. Rgk1 is required for both ASM and ARM. Moreover, N

  11. Robotic Mirror Therapy System for Functional Recovery of Hemiplegic Arms.

    Science.gov (United States)

    Beom, Jaewon; Koh, Sukgyu; Nam, Hyung Seok; Kim, Wonshik; Kim, Yoonjae; Seo, Han Gil; Oh, Byung-Mo; Chung, Sun Gun; Kim, Sungwan

    2016-08-15

    Mirror therapy has been performed as effective occupational therapy in a clinical setting for functional recovery of a hemiplegic arm after stroke. It is conducted by eliciting an illusion through use of a mirror as if the hemiplegic arm is moving in real-time while moving the healthy arm. It can facilitate brain neuroplasticity through activation of the sensorimotor cortex. However, conventional mirror therapy has a critical limitation in that the hemiplegic arm is not actually moving. Thus, we developed a real-time 2-axis mirror robot system as a simple add-on module for conventional mirror therapy using a closed feedback mechanism, which enables real-time movement of the hemiplegic arm. We used 3 Attitude and Heading Reference System sensors, 2 brushless DC motors for elbow and wrist joints, and exoskeletal frames. In a feasibility study on 6 healthy subjects, robotic mirror therapy was safe and feasible. We further selected tasks useful for activities of daily living training through feedback from rehabilitation doctors. A chronic stroke patient showed improvement in the Fugl-Meyer assessment scale and elbow flexor spasticity after a 2-week application of the mirror robot system. Robotic mirror therapy may enhance proprioceptive input to the sensory cortex, which is considered to be important in neuroplasticity and functional recovery of hemiplegic arms. The mirror robot system presented herein can be easily developed and utilized effectively to advance occupational therapy.

  12. Patterns of arm muscle activation involved in octopus reaching movements.

    Science.gov (United States)

    Gutfreund, Y; Flash, T; Fiorito, G; Hochner, B

    1998-08-01

    The extreme flexibility of the octopus arm allows it to perform many different movements, yet octopuses reach toward a target in a stereotyped manner using a basic invariant motor structure: a bend traveling from the base of the arm toward the tip (Gutfreund et al., 1996a). To study the neuronal control of these movements, arm muscle activation [electromyogram (EMG)] was measured together with the kinematics of reaching movements. The traveling bend is associated with a propagating wave of muscle activation, with maximal muscle activation slightly preceding the traveling bend. Tonic activation was occasionally maintained afterward. Correlation of the EMG signals with the kinematic variables (velocities and accelerations) reveals that a significant part of the kinematic variability can be explained by the level of muscle activation. Furthermore, the EMG level measured during the initial stages of movement predicts the peak velocity attained toward the end of the reaching movement. These results suggest that feed-forward motor commands play an important role in the control of movement velocity and that simple adjustment of the excitation levels at the initial stages of the movement can set the velocity profile of the whole movement. A simple model of octopus arm extension is proposed in which the driving force is set initially and is then decreased in proportion to arm diameter at the bend. The model qualitatively reproduces the typical velocity profiles of octopus reaching movements, suggesting a simple control mechanism for bend propagation in the octopus arm.

  13. Synthesis of Well-Defined Three-Arm Star-Branched Polystyrene through Arm-First Coupling Approach by Atom Transfer Radical Polymerization

    Directory of Open Access Journals (Sweden)

    Syed Shahabuddin

    2015-01-01

    Full Text Available Here we describe a simple route to synthesize three-arm star-branched polystyrene. Atom transfer radical polymerization technique has been utilized to yield branched polystyrene involving Williamson coupling strategy. Initially a linear polymeric chain of predetermined molecular weight has been synthesized which is further end-functionalized into a primary alkyl bromide moiety, a prime requisition for Williamson reaction. The end-functionalized polymer is then coupled using 1,1,1-tris(4-hydroxyphenylethane, a trifunctional core molecule, to give well-defined triple-arm star-branched polystyrene.

  14. Inter-Arm Difference in Brachial Blood Pressure in the General Population of Koreans.

    Science.gov (United States)

    Song, Bo Mi; Kim, Hyeon Chang; Shim, Jee-Seon; Lee, Myung Ha; Choi, Dong Phil

    2016-05-01

    We investigated the inter-arm difference in blood pressure of the general Korean population to identify associated factors. A total of 806 participants aged 30 to 64 years without history of major cardiovascular disease were analyzed in this cross-sectional study. They participated in the Cardiovascular and Metabolic Disease Etiology Research Center cohort study that began in 2013. Brachial blood pressure was measured simultaneously for both arms using an automated oscillometric device equipped with two cuffs in seated position. After five minutes of rest, systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured three times. The average of the three measurements was used for analysis. Multivariate logistic regression models were used to identify factors associated with inter-arm differences in blood pressure. The mean inter-arm difference was 3.3 mmHg for SBP and 2.0 mmHg for DBP. Large inter-arm differences (≥10 mmHg) in SBP and in DBP were found in 3.7% and 0.9% of subjects, respectively. A large inter-arm difference in SBP was associated with mean SBP (p=0.002) and C-reactive protein (p=0.014) while a large inter-arm different in DBP was only associated with body mass index (p=0.015). Sex, age, and anti-hypertensive medication use were not associated with differences in inter-arm blood pressure. Large inter-arm difference in blood pressure is only present in a small portion of healthy Korean adults. Our findings suggest that high SBP, chronic inflammation, and obesity may be associated with larger difference in inter-arm blood pressure.

  15. Increasing Opportunities for Question-Asking in School-Aged Children with Autism Spectrum Disorder: Effectiveness of Staff Training in Pivotal Response Treatment

    Science.gov (United States)

    Verschuur, Rianne; Huskens, Bibi; Verhoeven, Ludo; Didden, Robert

    2017-01-01

    Deficits in question-asking are common in children with autism spectrum disorder (ASD). Furthermore, their opportunities to self-initiate questions are often hindered by directive behavior of their conversation partners. This study assessed the effectiveness of staff training in pivotal response treatment (PRT) on staff member-created…

  16. Piezoelectric micromotor based on the structure of serial bending arms.

    Science.gov (United States)

    Tong, Jianhua; Cui, Tianhong; Shao, Peige; Wang, Liding

    2003-09-01

    This paper presents a new piezoelectric micromotor based on the structure of serial bending arms. Serial bending arms are composed of two piezoelectric bimorphs with one end fixed and the other end free, driven by two signals of a biased square wave with a phase difference of pi/2. The free end of a cantilever arm will move along an elliptic orbit so that the cantilever is used to drive a cylinder rotor. The rotor's end surface contacts the free end of the cantilever, resulting in the rotor's rotation. There are six serial bending arms anchored on the base. The driving mechanism of the micromotor is proposed and analyzed. A new micromotor prototype, 5 mm in diameter, has been fabricated and characterized. The maximum rotational speed reaches 325 rpm, and the output torque is about 36.5 microNm.

  17. Mutation of the conserved Gly83 and Gly94 in Escherichia coli elongation factor Tu. Indication of structural pivots

    DEFF Research Database (Denmark)

    Kjaersgård, I V; Knudsen, Charlotte Rohde; Wiborg, O

    1995-01-01

    Elongation factor Tu from Escherichia coli cycles between an active conformation where GTP is bound, and an inactive conformation where GDP is bound. Between the two conformations, elongation factor Tu undergoes major structural changes. The aim of this work has been to reveal the role of two ver...... is an important pivot point in elongation factor-Tu. Udgivelsesdato: 1995-Feb-15...

  18. Optimal Control of Holding Motion by Nonprehensile Two-Cooperative-Arm Robot

    Directory of Open Access Journals (Sweden)

    Changan Jiang

    2016-01-01

    Full Text Available Recently, more researchers have focused on nursing-care assistant robot and placed their hope on it to solve the shortage problem of the caregivers in hospital or nursing home. In this paper, a nonprehensile two-cooperative-arm robot is considered to realize holding motion to keep a two-rigid-link object (regarded as a care-receiver stable on the robot arms. By applying Newton-Euler equations of motion, dynamic model of the object is obtained. In this model, for describing interaction behavior between object and robot arms in the normal direction, a viscoelastic model is employed to represent the normal forces. Considering existence of friction between object and robot arms, LuGre dynamic model is applied to describe the friction. Based on the obtained model, an optimal regulator is designed to control the holding motion of two-cooperative-arm robot. In order to verify the effectiveness of the proposed method, simulation results are shown.

  19. Embodied prosthetic arm stabilizes body posture, while unembodied one perturbs it.

    Science.gov (United States)

    Imaizumi, Shu; Asai, Tomohisa; Koyama, Shinichi

    2016-10-01

    Senses of ownership (this arm belongs to me) and agency (I am controlling this arm) originate from sensorimotor system. External objects can be integrated into the sensorimotor system following long-term use, and recognized as one's own body. We examined how an (un)embodied prosthetic arm modulates whole-body control, and assessed the components of prosthetic embodiment. Nine unilateral upper-limb amputees participated. Four frequently used their prosthetic arm, while the others rarely did. Their postural sway was measured during quiet standing with or without their prosthesis. The frequent users showed greater sway when they removed the prosthesis, while the rare users showed greater sway when they fitted the prosthesis. Frequent users reported greater everyday feelings of postural stabilization by prosthesis and a larger sense of agency over the prosthesis. We suggest that a prosthetic arm maintains or perturbs postural control, depending on the prosthetic embodiment, which involves sense of agency rather than ownership. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. 78 FR 46579 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-08-01

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-30] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...: FMS case YAD-$22M-16Jan10. (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: None...