  1. Impact of the COBAS AmpliPrep/COBAS AMPLICOR HIV-1 MONITOR Test, Version 1.5, on Clinical Laboratory Operations▿

    Science.gov (United States)

    Germer, Jeffrey J.; Bendel, Jordan L.; Dolenc, Craig A.; Nelson, Sarah R.; Masters, Amanda L.; Gerads, Tara M.; Mandrekar, Jayawant N.; Mitchell, P. Shawn; Yao, Joseph D. C.

    2007-01-01

    The COBAS AmpliPrep/COBAS AMPLICOR HIV-1 MONITOR Test, version 1.5 (CAP/CA), and the COBAS AMPLICOR HIV-1 MONITOR Test, version 1.5, were compared. CAP/CA reduced and consolidated labor while modestly increasing assay throughput without increased failure rates or direct costs, regardless of batch size and assay format. PMID:17634308

  2. Establishing diagnostic cut-off criteria for the COBAS AmpliPrep/COBAS TaqMan HIV-1 Qualitative test through validation against the Amplicor DNA test v1.5 for infant diagnosis using dried blood spots.

    Science.gov (United States)

    Maritz, Jean; Preiser, Wolfgang; van Zyl, Gert U

    2012-02-01

    As antibody testing cannot confirm HIV-1 infection in children less than 18 months of age, diagnosis in these children depends on nucleic acid testing. The COBAS(®) AmpliPrep/COBAS(®) TaqMan(®) (CAP/CTM, Roche(®) Molecular Systems, Inc., Branchburg, NJ) HIV-1 Qualitative test is a total nucleic acid real-time PCR assay utilising whole EDTA blood or dried blood spots (DBS), which recently replaced the Roche(®) AMPLICOR(®) DNA test v1.5 (Amplicor) as the diagnostic HIV PCR assay in many South African laboratories. For the Amplicor assay, stringent diagnostic criteria were previously formulated for the local population, and a comparison reported the CAP/CTM's sensitivity at 99.7% and specificity at 100% for both sample types compared to these Amplicor criteria. To validate the assay prior to introduction in our laboratory and to define stringent diagnostic cut-off criteria. Whole EDTA blood samples from patients younger than 18 months sent for routine HIV-1 diagnosis were tested by Amplicor, and positive results were confirmed from DBS. CAP/CTM assays were subsequently performed from DBS. The CAP/CTM had a sensitivity of 98.8% and a specificity of 97.1%, but a positive predictive value (PPV) of only 78.7% compared to the Amplicor assay. Samples positive by CAP/CTM but negative by Amplicor displayed poor amplification curves compared to concordant positive samples. Upon re-testing those with sufficient material available by CAP/CTM, all showed negative results. The decreased PPV may either be due to false positive CAP/CTM results, or increased sensitivity compared to the Amplicor assay. Criteria were formulated for defining presumed false-positive results. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Evaluation of the NucliSens EasyQ v2.0 assay in comparison with the Roche Amplicor v1.5 and the Roche CAP/CTM HIV-1 Test v2.0 in quantification of C-clade HIV-1 in plasma.

    Directory of Open Access Journals (Sweden)

    Maximilian Muenchhoff

    Full Text Available Human immunodeficiency virus type 1 (HIV-1 genetic diversity poses a challenge to reliable viral load monitoring. Discrepancies between different testing platforms have been observed, especially for non-clade-B virus. Therefore we compare, in antiretroviral therapy (ART-naïve South African subjects predominantly infected with HIV-1 clade-C, three commercially available assays: the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test version 2.0 by Roche (CAP/CTM v2.0, the BioMérieux NucliSens Version 2.0 Easy Q/Easy Mag (NucliSens v2.0 and the Roche COBAS Amplicor HIV-1 Monitor Test Version 1.5 (Amplicor v1.5. Strong linear correlation was observed and Bland-Altman analyses showed overall good agreement between the assays with mean viral load differences of 0.078 log cp/ml (NucliSens v2.0 - Amplicor v1.5, 0.260 log cp/ml (CAP/CTM v2.0 - Amplicor v1.5 and 0.164 log cp/ml (CAP/CTM v2.0 - NucliSens v2.0, indicating lower mean viral load results for the Amplicor v1.5 and higher mean readings for the CAP/CTM v2.0. Consistent with observations following previous comparisons of CAP/CTM v2.0 versus Amplicor v1.5, the CAP/CTM v2.0 assay detected low-level viremia (median 65 cp/ml in more than one-third of those in whom viremia had been undetectable (<20 cp/ml in assays using the NucliSens platform. These levels of viremia are of uncertain clinical significance but may be of importance in early detection of ART resistance in those on treatment. Overall the three assays showed good comparability of results but with consistent, albeit relatively small, discrepancies for HIV-1 clade-C samples, especially in the low-viremic range that should be taken into account when interpreting viral load data.

  4. Performance evaluation of the new Roche cobas AmpliPrep/cobas TaqMan HCV test, version 2.0, for detection and quantification of hepatitis C virus RNA

    NARCIS (Netherlands)

    S.D. Pas (Suzan); R. Molenkamp (Richard); J. Schinkel (Janke); S. Rebers; C. Copra (Cederick); S. Seven-Deniz; D. Thamke (Diana); R.J. de Knegt (Robert); B.L. Haagmans (Bart); M. Schutten (Martin)

    2013-01-01

    textabstractTo evaluate the analytical performance and explore the clinical applicability of the new Roche cobas AmpliPrep/cobas TaqMan HCV test, v2.0 (CAP/CTM v2.0), a platform comparison was performed on panels and diagnostic samples with the Roche cobas AmpliPrep/cobas TaqMan HCV test (CAP/CTM

  5. Transference of CALIPER pediatric reference intervals to biochemical assays on the Roche cobas 6000 and the Roche Modular P.

    Science.gov (United States)

    Higgins, Victoria; Chan, Man Khun; Nieuwesteeg, Michelle; Hoffman, Barry R; Bromberg, Irvin L; Gornall, Doug; Randell, Edward; Adeli, Khosrow

    2016-01-01

    The Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) has recently established pediatric age- and sex-specific reference intervals for over 85 biochemical markers on the Abbott Architect system. Previously, CALIPER reference intervals for several biochemical markers were successfully transferred from Abbott assays to Roche, Beckman, Ortho, and Siemens assays. This study further broadens the CALIPER database by performing transference and verification for 52 biochemical assays on the Roche cobas 6000 and the Roche Modular P. Using CLSI C28-A3 and EP9-A2 guidelines, transference of the CALIPER reference intervals was attempted for 16 assays on the Roche cobas 6000 and 36 on the Modular P. Calculated reference intervals were further verified using 100 healthy CALIPER samples. Most assays showed strong correlation between assay systems and were transferable from Abbott to the Roche cobas 6000 (81%) and the Modular P (86%). Bicarbonate and magnesium were not transferable on either system and calcium and prealbumin were not transferable to the Modular P. Of the transferable analytes, 62% and 61% were verified on the cobas 6000 and the Modular P, respectively. This study extends the utility of the CALIPER database to two additional analytical systems, which facilitates the broad application of CALIPER reference intervals at pediatric centers utilizing Roche biochemical assays. Transference studies across different analytical platforms can later be collectively analyzed in an attempt to develop common reference intervals across all clinical chemistry instruments to harmonize laboratory test interpretation in diagnosis and monitoring of pediatric disease. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. The Roche Immunoturbidimetric Albumin Method on Cobas c 501 Gives Higher Values Than the Abbott and Roche BCP Methods When Analyzing Patient Plasma Samples.

    Science.gov (United States)

    Helmersson-Karlqvist, Johanna; Flodin, Mats; Havelka, Aleksandra Mandic; Xu, Xiao Yan; Larsson, Anders

    2016-09-01

    Serum/plasma albumin is an important and widely used laboratory marker and it is important that we measure albumin correctly without bias. We had indications that the immunoturbidimetric method on Cobas c 501 and the bromocresol purple (BCP) method on Architect 16000 differed, so we decided to study these methods more closely. A total of 1,951 patient requests with albumin measured with both the Architect BCP and Cobas immunoturbidimetric methods were extracted from the laboratory system. A comparison with fresh plasma samples was also performed that included immunoturbidimetric and BCP methods on Cobas c 501 and analysis of the international protein calibrator ERM-DA470k/IFCC. The median difference between the Abbott BCP and Roche immunoturbidimetric methods was 3.3 g/l and the Roche method overestimated ERM-DA470k/IFCC by 2.2 g/l. The Roche immunoturbidimetric method gave higher values than the Roche BCP method: y = 1.111x - 0.739, R² = 0.971. The Roche immunoturbidimetric albumin method gives clearly higher values than the Abbott and Roche BCP methods when analyzing fresh patient samples. The differences between the two methods were similar at normal and low albumin levels. © 2016 Wiley Periodicals, Inc.

  7. Performance evaluation of cobas HBV real-time PCR assay on Roche cobas 4800 System in comparison with COBAS AmpliPrep/COBAS TaqMan HBV Test.

    Science.gov (United States)

    Kim, Hanah; Hur, Mina; Bae, Eunsin; Lee, Kyung-A; Lee, Woo-In

    2018-02-19

    Hepatitis B virus (HBV) nucleic acid amplification testing (NAAT) is important for the diagnosis and management of HBV infection. We evaluated the analytical performance of the cobas HBV NAAT (Roche Diagnostics GmbH, Mannheim, Germany) on the cobas 4800 System in comparison with COBAS AmpliPrep/COBAS TaqMan HBV Test (CAP/CTM HBV). Precision was evaluated using three levels of cobas HBV/HCV/HIV-1 Control Kit, and linearity was evaluated across the anticipated measuring range (10.0-1.0×109 IU/mL) at seven levels using clinical samples. Detection capability, including limit of blank (LOB), limit of detection (LOD) and limit of quantitation (LOQ), was verified using the 4th WHO International Standard for HBV DNA for NAT (NIBSC code: 10/266). Correlation between the two systems was compared using 205 clinical samples (102 sera and 103 EDTA plasma). Repeatability and total imprecision (coefficient of variation) ranged from 0.5% to 3.8% and from 0.5% to 3.5%, respectively. Linearity (coefficient of determination, R2) was 0.999. LOB, LOD and LOQ were all acceptable within the observed proportion rate (85%). Correlation was very high between the two systems in both serum and plasma samples (correlation coefficient [r]=0.995). The new cobas HBV real-time PCR assay on the cobas 4800 System showed reliable analytical performances.

  8. Comparison of COBAS AMPLICOR Neissefia gonorrhoeae PCR, including confirmation with N-gonorrhoeae-specific 16S rRNA PCR, with traditional culture

    NARCIS (Netherlands)

    Luijt, DS; Bos, PAJ; van Zwet, AA; Vader, PCV; Schirm, J

    A total of 3,023 clinical specimens were tested for Neisseria gonorrhoeae by using COBAS AMPLICOR (CA) PCR and confirmation of positives by N. gonorrhoeae-specific 16S rRNA PCR. The sensitivity of CA plus 16S rRNA PCR was 98.8%, compared to 68.2% for culture. Confirmation of CA positives increased

  9. Utility of the Roche Cobas 4800 for detection of high-risk human papillomavirus in formalin-fixed paraffin-embedded oropharyngeal squamous cell carcinoma.

    Science.gov (United States)

    Pettus, Jason R; Wilson, Terri L; Steinmetz, Heather B; Lefferts, Joel A; Tafe, Laura J

    2017-02-01

    Clinical laboratories are expected to reliably identify human papilloma virus (HPV) associated oropharyngeal squamous cell carcinoma (OPSCC) for prognostic and potential therapeutic applications. In addition to surrogate p16 immunohistochemistry (IHC) testing, DNA-based HPV-specific testing strategies are widely utilized. Recognizing the efficiency of the Roche Cobas 4800 platform for testing gynecological cytology specimens for high-risk HPV, we elected to evaluate the potential utility of this platform for testing formalin-fixed paraffin-embedded (FFPE) OPSCC tissue. Using the Roche Linear Array assay for comparison, we tested twenty-eight samples (16 primary OPSCC, 2 lymph node metastases from primary OPSCC, 1 oral tongue carcinoma, 3 benign squamous papillomas, and 3 non-oropharyngeal carcinoma tissues). Excluding two invalid results, the Roche Cobas 4800 testing resulted in excellent inter-assay concordance (25/26, 96.2%) and 100% concordance for HPV-16/HPV-18 positive samples. This data suggests that the Roche Cobas 4800 platform may be a cost-effective method for testing OPSCC FFPE tissues in a clinical molecular pathology laboratory setting. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Multicenter evaluation of the new Abbott RealTime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA

    NARCIS (Netherlands)

    Schutten, Martin; Peters, D; Back, N K T; Beld, M; Beuselinck, K; Foulongne, V; Geretti, A-M; Pandiani, L; Tiemann, C; Niesters, H G M

    The analytical performances of the new Abbott RealTime hepatitis C virus (HCV) and human immunodeficiency virus type 1 viral load assays were compared at nine laboratories with different competitor assays. These included the Abbott LcX, Bayer Versant bDNA, Roche COBAS Amplicor, and Roche COBAS

  11. Multicenter evaluation of the new Abbott RealTime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA

    NARCIS (Netherlands)

    Schutten, M.; Peters, D.; Back, N. K. T.; Beld, M.; Beuselinck, K.; Foulongne, V.; Geretti, A.-M.; Pandiani, L.; Tiemann, C.; Niesters, H. G. M.

    2007-01-01

    The analytical performances of the new Abbott RealTime hepatitis C virus (HCV) and human immunodeficiency virus type 1 viral load assays were compared at nine laboratories with different competitor assays. These included the Abbott LcX, Bayer Versant bDNA, Roche COBAS Amplicor, and Roche COBAS

  12. Body fluid matrix evaluation on a Roche cobas 8000 system.

    Science.gov (United States)

    Owen, William E; Thatcher, Mindy L; Crabtree, Karolyn J; Greer, Ryan W; Strathmann, Frederick G; Straseski, Joely A; Genzen, Jonathan R

    2015-09-01

    Chemical analysis of body fluids is commonly requested by physicians. Because most commercial FDA-cleared clinical laboratory assays are not validated by diagnostic manufacturers for "non-serum" and "non-plasma" specimens, laboratories may need to complete additional validation studies to comply with regulatory requirements regarding body fluid testing. The objective of this report is to perform recovery studies to evaluate potential body fluid matrix interferences for commonly requested chemistry analytes. Using an IRB-approved protocol, previously collected clinical body fluid specimens (biliary/hepatic, cerebrospinal, dialysate, drain, pancreatic, pericardial, peritoneal, pleural, synovial, and vitreous) were de-identified and frozen (-20°C) until experiments were performed. Recovery studies (spiking with high concentration serum, control, and/or calibrator) were conducted using 10% spiking solution by volume; n=5 specimens per analyte/body fluid investigated. Specimens were tested on a Roche cobas 8000 system (c502, c702, e602, and ISE modules). In all 80 analyte/body fluid combinations investigated (including amylase, total bilirubin, urea nitrogen, carbohydrate antigen 19-9, carcinoembryonic antigen, cholesterol, chloride, creatinine, glucose, potassium, lactate dehydrogenase, lipase, rheumatoid factor, sodium, total protein, triglycerides, and uric acid), the average percent recovery was within predefined acceptable limits (less than ±10% from the calculated ideal recovery). The present study provides evidence against the presence of any systematic matrix interference in the analyte/body fluid combinations investigated on the Roche cobas 8000 system. Such findings support the utility of ongoing body fluid validation initiatives conducted to maintain compliance with regulatory requirements. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Evaluation of a third party enzymatic ammonia method for use on the Roche Cobas 6000 (c501) automated platform.

    Science.gov (United States)

    Seiden-Long, Isolde; Schnabl, Kareena; Skoropadyk, Wendy; Lennon, Nola; McKeage, Arlayne

    2014-08-01

    Adaptation of the Randox Enzymatic Manual UV Ammonia method to be used on the Roche Cobas 6000 (c501) automated analyzer platform. The Randox ammonia reagent was evaluated for precision, linearity, accuracy and interference from hemolysis, icterus and lipemia on the Roche c501 analyzer. Comparison studies were conducted for the Randox reagent between Roche c501, Siemens Vista, Ortho Vitros 250, and Beckman DxC methods. The Randox reagent demonstrates acceptable within-run (L1=65 μmol/L, CV 3.4% L2=168 μmol/L, CV 1.9%) and between-run precision (L1=29 μmol/L, CV 7.3% L2=102 μmol/L, CV 3.0%), Analytical Measurement Range (7-940 μmol/L), and accuracy. The method interference profile is superior for the Randox method (hemolysis index up to 600, icteric index up to 60, lipemic index up to 100) as compared to the Roche method (hemolysis index up to 200, icteric index up to 10, lipemic index up to 50). Comparison was very good between the Randox reagent and two other wet chemistry platforms. The Randox Enzymatic Manual UV Ammonia reagent is an available alternative to the Roche Cobas c501 reagent. The method is more robust to endogenous interferences and less prone to instrument error flags, thus allowing the majority of clinical specimens to be reported without additional sample handling at our institution. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. Meticulous plasma isolation is essential to avoid false low-level viraemia in Roche Cobas HIV-1 viral load assays.

    Science.gov (United States)

    Mortier, Virginie; Vancoillie, Leen; Dauwe, Kenny; Staelens, Delfien; Demecheleer, Els; Schauvliege, Marlies; Dinakis, Sylvie; Van Maerken, Tom; Dessilly, Géraldine; Ruelle, Jean; Verhofstede, Chris

    2017-10-24

    Pre-analytical sample processing is often overlooked as a potential cause of inaccurate assay results. Here we demonstrate how plasma, extracted from standard EDTA-containing blood collection tubes, may contain traces of blood cells consequently resulting in a false low-level HIV-1 viral load when using Roche Cobas HIV-1 assays. The presence of human DNA in Roche Cobas 4800 RNA extracts and in RNA extracts from the Abbott HIV-1 RealTime assay was assessed by quantifying the human albumin gene by means of quantitative PCR. RNA was extracted from plasma samples before and after an additional centrifugation and tested for viral load and DNA contamination. The relation between total DNA content and viral load was defined. Elevated concentrations of genomic DNA were detected in 28 out of 100 Cobas 4800 extracts and were significantly more frequent in samples processed outside of the AIDS Reference Laboratory. An association between genomic DNA presence and spurious low-level viraemia results was demonstrated. Supplementary centrifugation of plasma before RNA extraction eliminated the contamination and the false viraemia. Plasma isolated from standard EDTA-containing blood collection tubes may contain traces of HIV DNA leading to false viral load results above the clinical cutoff. Supplementary centrifugation of plasma before viral load analysis may eliminate the occurrence of this spurious low-level viraemia.

  15. Multicenter evaluation of the new Abbott Realtime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA

    NARCIS (Netherlands)

    M. Schutten (Martin); D. Peters (D.); N. Back (Nicole); A.W. van den Beld (Annewieke); B. Beuselinck (B.); V. Foulongne (V.); A.M. Geretti (Anna Maria); L. Pandiani (L.); M. Tiemann; H.G.M. Niesters (Bert)

    2007-01-01

    textabstractThe analytical performances of the new Abbott RealTime hepatitis C virus (HCV) and human immunodeficiency virus type 1 viral load assays were compared at nine laboratories with different competitor assays. These included the Abbott LcX, Bayer Versant bDNA, Roche COBAS Amplicor, and Roche

  16. Characterization and Validation of the LT-SYS Copper Assay on a Roche Cobas 8000 c502 Analyzer.

    Science.gov (United States)

    Kraus, F Bernhard; Mischereit, Marlies; Eller, Christoph; Ludwig-Kraus, Beatrice

    2017-02-01

    Validation of the LT-SYS quantitative in vitro copper assay on a Roche Cobas 8000 c502 analyzer and comparison with a BIOMED assay on a Roche Cobas Mira analyzer. Imprecision and bias were quantified at different concentration levels (serum and plasma) over a 20-day period. Linearity was assessed covering a range from 4.08 µmol/L to 33.8 µmol/L. Limit of blank (LoB) and limit of detection (LoD) were established based on a total of 120 blank and low-level samples. The method comparison was based on 58 plasma samples. Within-run imprecision ranged from 0.7% to 1.2% and within-laboratory imprecision from 1.4% to 3.3%. Relative bias for the 2 serum pools with known target values was less than 2.5%. The assay did not deviate from linearity over the tested measuring range. LoB and LoD were 0.12 µmol/L and 0.23 µmol/L, respectively. The method comparison revealed an average deviation of 11.5% (2.016 µmol/L), and the linear regression fit was y = 1.464 + 0.795x. The LT-SYS copper assay characterized in this study showed a fully acceptable performance with good degrees of imprecision and bias, no deviation from linearity in the relevant measuring rangem, and very low LoB and LoD. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Comparison of the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 test v1.0 with v2.0 in HIV-1 viral load quantification

    Directory of Open Access Journals (Sweden)

    Yi-Ching Tung

    2015-04-01

    Full Text Available Roche modified the COBAS AmpliPrep/COBAS TaqMan human immunodeficiency virus type 1 (HIV-1 test version 1.0 (CAP/CTM v1.0, resulting in the COBAS AmpliPrep/COBAS TaqMan HIV-1 test version 2.0 (CAP/CTM v2.0. The aim of this study was to evaluate the performance of the CAP/CTM v2.0 and to compare this performance with that of the CAP/CTM v1.0. The study was conducted in a small local study group in Kaohsiung Medical University Hospital, Kaohsiung, Taiwan. A total of 86 plasma samples from HIV-1-seropositive patients were tested using the two assays. The correlation and concordance of results between the two assays were calculated. The CAP/CTM v2.0 generated higher values than did the CAP/CTM v1.0, and five samples (5.8% yielded a difference of > 1 log10 copies/mL. In addition, our data show that CAP/CTM v1.0 and CAP/CTM v2.0 yielded relatively consistent values for 23 samples with low viral loads (< 200 copies/mL. Furthermore, when viral loads were in a medium range (2–5 log10 copies/mL, the results of the two assays were more compatible. This study shows a good correlation between CAP/CTM v1.0 and v2.0 in HIV-1 viral load measurement. Further attention must be paid to those cases in which measured viral loads present larger differences between the two assays.

  18. Measurement Differences Between Two Immunoassay Systems for LH and FSH: A Comparison of Roche Cobas e601 vs. Abbott Architect i2000sr.

    Science.gov (United States)

    Yin, Lianli; Tang, Yinghua; Chen, Xiang; Sun, Yifan

    2018-03-01

    Follicle-stimulating hormone (FSH) and luteinizing hormone (LH) regulate the growth and reproductive activity of gonadal tissue and determine the concentration of LH is essential for the prediction of ovulation. Collectively, FSH and LH are important measurements to ascertain the causes of infertility as well as diagnosing disorders such as polycystic ovary syndrome and pituitary and gonadal dysfunction. This study compares the correlation between LH and FSH measurements during examination with two different systems, Architect i2000sr (Abbott Laboratories; Lake Bluff, IL, USA) and Cobas e601 (Roche; Geneva, Switzerland), and assesses the differences between these systems. Serum analysis was performed for 95 patients using both the Cobas e601 and Architect i2000sr systems. The method used to compare the systems was Passing-Bablok regression analysis with a Bland-Altman agreement plot. Inter-rater agreement was analyzed using a concordance correlation coefficient. Architect i2000sr and Cobas e601 have strong correlations in their LH and FSH results. However, the Bland-Altman plot shows that LH and FSH measurements in Cobas e601 are about 1.31 times and 1.26 times higher than those in Architect i2000sr, respectively. Passing-Bablok regression analysis also shows significant proportional deviation between them. The difference between the test results for LH and FSH in Cobas e601 and Architect i2000sr indicate that the results from one system cannot be directly used to evaluate the other system.

  19. Automated Extraction of Formalin-Fixed, Paraffin-Embedded Tissue for High-Risk Human Papillomavirus Testing of Head and Neck Squamous Cell Carcinomas Using the Roche Cobas 4800 System.

    Science.gov (United States)

    Kerr, Darcy A; Sweeney, Brenda; Arpin, Ronald N; Ring, Melissa; Pitman, Martha B; Wilbur, David C; Faquin, William C

    2016-08-01

    -Testing for high-risk human papillomavirus (HR-HPV) in head and neck squamous cell carcinomas (HNSCCs) is important for both prognostication and clinical management. Several testing platforms are available for HR-HPV; however, effective alternative automated approaches are needed. -To assess the performance of the automated Roche cobas 4800 HPV real-time polymerase chain reaction-based system on formalin-fixed, paraffin-embedded HNSCC specimens and compare results with standard methods of in situ hybridization (ISH) and p16 immunohistochemistry. -Formalin-fixed, paraffin-embedded samples of HNSCC were collected from archival specimens in the Department of Pathology, Massachusetts General Hospital (Boston), and prepared using the automated system by deparaffinization and dehydration followed by tissue lysis. Samples were integrated into routine cervical cytology testing runs by cobas. Corresponding formalin-fixed, paraffin-embedded samples were evaluated for HR-HPV by ISH and p16 by immunohistochemistry. Discrepant cases were adjudicated by polymerase chain reaction. -Sixty-two HNSCC samples were analyzed using the automated cobas system, ISH, and immunohistochemistry. Fifty-two percent (n = 32 of 62) of formalin-fixed, paraffin-embedded tumors were positive for HR-HPV by cobas. Eighty-eight percent (n = 28 of 32) of cases were the HPV 16 subtype and 12% (n = 4 of 32) were other HR-HPV subtypes. Corresponding testing with ISH was concordant in 92% (n = 57 of 62) of cases. Compared with the adjudication polymerase chain reaction standard, there were 3 false-positive cases by cobas. -Concordance in HNSCC HR-HPV status between cobas and ISH was more than 90%. The cobas demonstrated a sensitivity of 100% and a specificity of 91% for detection of HR-HPV. Advantages favoring cobas include its automation, cost efficiency, objective results, and ease of performance.

  20. Comparison of the Abbott m2000 HIV-1 Real-Time and Roche AMPLICOR Monitor v1.5 HIV-1 assays on plasma specimens from Rakai, Uganda.

    Science.gov (United States)

    Ssebugenyi, I; Kizza, A; Mpoza, B; Aluma, G; Boaz, I; Newell, K; Laeyendecker, O; Shott, J P; Serwadda, D; Reynolds, S J

    2011-07-01

    The need for viral load (VL) monitoring of HIV patients receiving antiretroviral therapy (ART) in resource-limited settings (RLS) has become apparent with studies showing the limitations of immunological monitoring. We compared the Abbott m2000 Real-Time (Abbott) HIV-1 assay with the Roche AMPLICOR Monitor v1.5 (Roche) HIV-1 assay over a range of VL concentrations. Three hundred and eleven plasma samples were tested, including 164 samples from patients on ART ≥ six months and 147 from ART-naïve patients. The Roche assay detected ≥400 copies/mL in 158 (50.8%) samples. Of these, Abbott produced 145 (91.8%) detectable results ≥400 copies/mL; 13 (8.2%) samples produced discrepant results. Concordance between the assays for detecting HIV-1 RNA ≥400 copies/mL was 95.8% (298/311). The sensitivity, specificity, positive predictive value and negative predictive value of Abbott to detect HIV-1 RNA ≥400 copies/mL were 91.8%, 100%, 100% and 92.2%, respectively. For the 151 samples with HIV-1 RNA ≥400 copies/mL for both assays, a good linear correlation was found (r = 0.81, P Abbott assay performed well in our setting, offering an alternative methodology for HIV-1 VL for laboratories with realtime polymerase chain reaction (PCR) capacity.

  1. Comparison of the Abbott RealTime High Risk HPV test and the Roche cobas 4800 HPV test using urine samples.

    Science.gov (United States)

    Lim, Myong Cheol; Lee, Do-Hoon; Hwang, Sang-Hyun; Hwang, Na Rae; Lee, Bomyee; Shin, Hye Young; Jun, Jae Kwan; Yoo, Chong Woo; Lee, Dong Ock; Seo, Sang-Soo; Park, Sang-Yoon; Joo, Jungnam

    2017-05-01

    Human papillomavirus (HPV) testing based on cervical samples is important for use in cervical cancer screening. However, cervical sampling is invasive. Therefore, non-invasive methods for detecting HPV, such as urine samples, are needed. For HPV detection in urine samples, two real-time PCR (RQ-PCR) tests, Roche cobas 4800 test (Roche_HPV; Roche Molecular Diagnostics) and Abbott RealTime High Risk HPV test (Abbott_HPV; Abbott Laboratories) were compared to standard cervical samples. The performance of Roche_HPV and Abbott_HPV for HPV detection was evaluated at the National Cancer Center using 100 paired cervical and urine samples. The tests were also compared using urine samples stored at various temperatures and for a range of durations. The overall agreement between the Roche_HPV and Abbott_HPV tests using urine samples for any hrHPV type was substantial (86.0% with a kappa value of 0.7173), and that for HPV 16/18 was nearly perfect (99.0% with a kappa value of 0.9668). The relative sensitivities (based on cervical samples) for HPV 16/18 detection using Roche_HPV and Abbott_HPV with urine samples were 79.2% (95% CI; 57.9-92.9%) and 81.8% (95% CI; 59.7-94.8%), respectively. When the cut-off C T value for Abbott_HPV was extended to 40 for urine samples, the relative sensitivity of Abbott_HPV increased to 91.7% from 81.8% for HPV16/18 detection and to 87.0% from 68.5% for other hrHPV detection. The specificity was not affected by the change in the C T threshold. Roche_HPV and Abbott_HPV showed high concordance. However, HPV DNA detection using urine samples was inferior to HPV DNA detection using cervical samples. Interestingly, when the cut-off C T value was set to 40, Abbott_HPV using urine samples showed high sensitivity and specificity, comparable to those obtained using cervical samples. Fully automated DNA extraction and detection systems, such as Roche_HPV and Abbott_HPV, could reduce the variability in HPV detection and accelerate the standardization of HPV

  2. Precision, accuracy, cross reactivity and comparability of serum indices measurement on Abbott Architect c8000, Beckman Coulter AU5800 and Roche Cobas 6000 c501 clinical chemistry analyzers.

    Science.gov (United States)

    Nikolac Gabaj, Nora; Miler, Marijana; Vrtarić, Alen; Hemar, Marina; Filipi, Petra; Kocijančić, Marija; Šupak Smolčić, Vesna; Ćelap, Ivana; Šimundić, Ana-Maria

    2018-04-25

    The aim of our study was to perform verification of serum indices on three clinical chemistry platforms. This study was done on three analyzers: Abbott Architect c8000, Beckman Coulter AU5800 (BC) and Roche Cobas 6000 c501. The following analytical specifications were verified: precision (two patient samples), accuracy (sample with the highest concentration of interferent was serially diluted and measured values compared to theoretical values), comparability (120 patients samples) and cross reactivity (samples with increasing concentrations of interferent were divided in two aliquots and remaining interferents were added in each aliquot. Measurements were done before and after adding interferents). Best results for precision were obtained for the H index (0.72%-2.08%). Accuracy for the H index was acceptable for Cobas and BC, while on Architect, deviations in the high concentration range were observed (y=0.02 [0.01-0.07]+1.07 [1.06-1.08]x). All three analyzers showed acceptable results in evaluating accuracy of L index and unacceptable results for I index. The H index was comparable between BC and both, Architect (Cohen's κ [95% CI]=0.795 [0.692-0.898]) and Roche (Cohen's κ [95% CI]=0.825 [0.729-0.922]), while Roche and Architect were not comparable. The I index was not comparable between all analyzer combinations, while the L index was only comparable between Abbott and BC. Cross reactivity analysis mostly showed that serum indices measurement is affected when a combination of interferences is present. There is heterogeneity between analyzers in the hemolysis, icteria, lipemia (HIL) quality performance. Verification of serum indices in routine work is necessary to establish analytical specifications.

  3. Evaluation of NGAL TestTM on Cobas 6000

    DEFF Research Database (Denmark)

    Hansen, Young B L; Damgaard, Anette; Poulsen, Jørgen H

    2014-01-01

    BACKGROUND: Neutrophil Gelatinase-Associated Lipocalin (NGAL) is a promising biomarker for acute kidney injury (AKI). Our objectives were to evaluate the NGAL Test(TM) from Bioporto for both urine NGAL and plasma NGAL on the Cobas 6000 c501 (Roche Diagnostics, Rotkreuz, Switzerland) with matched...... measurements run on Hitachi 917, the method's linearity on the Cobas 6000 in urine, EDTA and Lithium-Heparin (Li-Hep), the influence of using EDTA or Li-Hep tubes and, finally, the impact of freezing and thawing on the sample. METHODS: Forty matched samples of Li-Hep and EDTA plasma and 40 urine samples were...

  4. Analytical characteristics and comparative evaluation of Aptima HCV quant Dx assay with the Abbott RealTime HCV assay and Roche COBAS AmpliPrep/COBAS TaqMan HCV quantitative test v2.0.

    Science.gov (United States)

    Worlock, A; Blair, D; Hunsicker, M; Le-Nguyen, T; Motta, C; Nguyen, C; Papachristou, E; Pham, J; Williams, A; Vi, M; Vinluan, B; Hatzakis, A

    2017-04-04

    The Aptima HCV Quant Dx assay (Aptima assay) is a fully automated quantitative assay on the Panther® system. This assay is intended for confirmation of diagnosis and monitoring of HCV RNA in plasma and serum specimens. The purpose of the testing described in this paper was to evaluate the performance of the Aptima assay. The analytical sensitivity, analytical specificity, precision, and linearity of the Aptima assay were assessed. The performance of the Aptima assay was compared to two commercially available HCV assays; the Abbott RealTime HCV assay (Abbott assay, Abbott Labs Illinois, USA) and the Roche COBAS Ampliprep/COBAS Taqman HCV Quantitative Test v2.0 (Roche Assay, Roche Molecular Systems, Pleasanton CA, USA). The 95% Lower Limit of Detection (LoD) of the assay was determined from dilutions of the 2nd HCV WHO International Standard (NIBSC 96/798 genotype 1) and HCV positive clinical specimens in HCV negative human plasma and serum. Probit analysis was performed to generate the 95% predicted detection limits. The Lower Limit of Quantitation (LLoQ) was established for each genotype by diluting clinical specimens and the 2nd HCV WHO International Standard (NIBSC 96/798 genotype 1) in HCV negative human plasma and serum. Specificity was determined using 200 fresh and 536 frozen HCV RNA negative clinical specimens including 370 plasma specimens and 366 serum specimens. Linearity for genotypes 1 to 6 was established by diluting armored RNA or HCV positive clinical specimens in HCV negative serum or plasma from 8.08 log IU/mL to below 1 log IU/mL. Precision was tested using a 10 member panel made by diluting HCV positive clinical specimens or spiking armored RNA into HCV negative plasma and serum. A method comparison was conducted against the Abbott assay using 1058 clinical specimens and against the Roche assay using 608 clinical specimens from HCV infected patients. In addition, agreement between the Roche assay and the Aptima assay using specimens with low

  5. Improving clinical laboratory efficiency: a time-motion evaluation of the Abbott m2000 RealTime and Roche COBAS AmpliPrep/COBAS TaqMan PCR systems for the simultaneous quantitation of HIV-1 RNA and HCV RNA.

    Science.gov (United States)

    Amendola, Alessandra; Coen, Sabrina; Belladonna, Stefano; Pulvirenti, F Renato; Clemens, John M; Capobianchi, M Rosaria

    2011-08-01

    Diagnostic laboratories need automation that facilitates efficient processing and workflow management to meet today's challenges for expanding services and reducing cost, yet maintaining the highest levels of quality. Processing efficiency of two commercially available automated systems for quantifying HIV-1 and HCV RNA, Abbott m2000 system and Roche COBAS Ampliprep/COBAS TaqMan 96 (docked) systems (CAP/CTM), was evaluated in a mid/high throughput workflow laboratory using a representative daily workload of 24 HCV and 72 HIV samples. Three test scenarios were evaluated: A) one run with four batches on the CAP/CTM system, B) two runs on the Abbott m2000 and C) one run using the Abbott m2000 maxCycle feature (maxCycle) for co-processing these assays. Cycle times for processing, throughput and hands-on time were evaluated. Overall processing cycle time was 10.3, 9.1 and 7.6 h for Scenarios A), B) and C), respectively. Total hands-on time for each scenario was, in order, 100.0 (A), 90.3 (B) and 61.4 min (C). The interface of an automated analyzer to the laboratory workflow, notably system set up for samples and reagents and clean up functions, are as important as the automation capability of the analyzer for the overall impact to processing efficiency and operator hands-on time.

  6. Laboratory blood analysis in Strigiformes-Part II: plasma biochemistry reference intervals and agreement between the Abaxis Vetscan V2 and the Roche Cobas c501.

    Science.gov (United States)

    Ammersbach, Mélanie; Beaufrère, Hugues; Gionet Rollick, Annick; Tully, Thomas

    2015-03-01

    Limited plasma biochemical information is available in Strigiformes. Only one study investigated the agreement between a point-of-care with a reference laboratory analyzer for biochemistry variables in birds. The objective was to report reference intervals (RI) for plasma biochemistry variables in Strigiformes, and to assess agreement between the Abaxis Vetscan V2 and Roche Cobas c501. A prospective study was designed to assess plasma biochemistry RI for concentration of calcium, phosphorus, total protein, albumin, globulin, glucose, bilirubin, uric acid, bile acids, sodium, potassium, and chloride, and activities of AST, GGT, CK, amylase, lipase, LDH, and GLDH. In addition, the agreement between the Vetscan and the Cobas in owl species was assessed. A total of 190 individuals were sampled belonging to 12 Strigiformes species including Barn Owls, Barred Owls, Great Horned Owls, Eurasian Eagle Owls, Spectacled Owls, Eastern Screech Owls, Long-Eared Owls, Short-Eared Owls, Great Gray Owls, Snowy Owls, Northern Saw-Whet Owls, and Northern Hawk-Owls. Order-, species-, and method-specific RI were determined on both analyzers. Although Vetscan data were not equivalent to the Cobas, 4 analytes (glucose, AST, CK, and total protein, with correction for bias) were within acceptable agreement, 3 analytes (uric acid, calcium, and phosphorus) were within close agreement, and the remaining analytes were in strong disagreement. Species-specific differences were observed notably for the concentration of glucose in Barn Owls and electrolytes in Northern Saw-Whet Owls. Overall, this study suggests that the Vetscan has acceptable clinical performance in Strigiformes for some analytes and highlights discrepancies for several analytes. © 2015 American Society for Veterinary Clinical Pathology.

  7. Quantification of Parvovirus B19 DNA Using COBAS AmpliPrep Automated Sample Preparation and LightCycler Real-Time PCR

    Science.gov (United States)

    Schorling, Stefan; Schalasta, Gunnar; Enders, Gisela; Zauke, Michael

    2004-01-01

    The COBAS AmpliPrep instrument (Roche Diagnostics GmbH, D-68305 Mannheim, Germany) automates the entire sample preparation process of nucleic acid isolation from serum or plasma for polymerase chain reaction analysis. We report the analytical performance of the LightCycler Parvovirus B19 Quantification Kit (Roche Diagnostics) using nucleic acids isolated with the COBAS AmpliPrep instrument. Nucleic acids were extracted using the Total Nucleic Acid Isolation Kit (Roche Diagnostics) and amplified with the LightCycler Parvovirus B19 Quantification Kit. The kit combination processes 72 samples per 8-hour shift. The lower detection limit is 234 IU/ml at a 95% hit-rate, linear range approximately 104-1010 IU/ml, and overall precision 16 to 40%. Relative sensitivity and specificity in routine samples from pregnant women are 100% and 93%, respectively. Identification of a persistent parvovirus B19-infected individual by the polymerase chain reaction among 51 anti-parvovirus B19 IgM-negative samples underlines the importance of additional nucleic acid testing in pregnancy and its superiority to serology in identifying the risk of parvovirus B19 transmission via blood or blood products. Combination of the Total Nucleic Acid Isolation Kit on the COBAS AmpliPrep instrument with the LightCycler Parvovirus B19 Quantification Kit provides a reliable and time-saving tool for sensitive and accurate detection of parvovirus B19 DNA. PMID:14736825

  8. Duplex detection of the Mycobacterium tuberculosis complex and medically important non-tuberculosis mycobacteria by real-time PCR based on the rnpB gene.

    Science.gov (United States)

    Abdeldaim, Guma; Svensson, Erik; Blomberg, Jonas; Herrmann, Björn

    2016-11-01

    A duplex real-time PCR based on the rnpB gene was developed for Mycobacterium spp. The assay was specific for the Mycobacterium tuberculosis complex (MTB) and also detected all 19 tested species of non-tuberculous mycobacteria (NTM). The assay was evaluated on 404 clinical samples: 290 respiratory samples and 114 from tissue and other non-respiratory body sites. M. tuberculosis was detected by culture in 40 samples and in 30 samples by the assay. The MTB assay showed a sensitivity similar to Roche Cobas Amplicor MTB-PCR (Roche Molecular Systems, Pleasanton, CA, USA). There were only nine samples with non-tuberculous mycobacteria detected by culture. Six of them were detected by the PCR assay. © 2016 APMIS. Published by John Wiley & Sons Ltd.

  9. Doubling immunochemistry laboratory testing efficiency with the cobas e 801 module while maintaining consistency in analytical performance.

    Science.gov (United States)

    Findeisen, P; Zahn, I; Fiedler, G M; Leichtle, A B; Wang, S; Soria, G; Johnson, P; Henzell, J; Hegel, J K; Bendavid, C; Collet, N; McGovern, M; Klopprogge, K

    2018-06-04

    The new immunochemistry cobas e 801 module (Roche Diagnostics) was developed to meet increasing demands on routine laboratories to further improve testing efficiency, while maintaining high quality and reliable data. During a non-interventional multicenter evaluation study, the overall performance, functionality and reliability of the new module was investigated under routine-like conditions. It was tested as a dedicated immunochemistry system at four sites and as a consolidator combined with clinical chemistry at three sites. We report on testing efficiency and analytical performance of the new module. Evaluation of sample workloads with site-specific routine request patterns demonstrated increased speed and almost doubled throughput (maximal 300 tests per h), thus revealing that one cobas e 801 module can replace two cobas e 602 modules while saving up to 44% floor space. Result stability was demonstrated by QC analysis per assay throughout the study. Precision testing over 21 days yielded excellent results within and between labs, and, method comparison performed versus the cobas e 602 module routine results showed high consistency of results for all assays under study. In a practicability assessment related to performance and handling, 99% of graded features met (44%) or even exceeded (55%) laboratory expectations, with enhanced reagent management and loading during operation being highlighted. By nearly doubling immunochemistry testing efficiency on the same footprint as a cobas e 602 module, the new module has a great potential to further consolidate and enhance laboratory testing while maintaining high quality analytical performance with Roche platforms. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  10. [Comparison of manual and automated (MagNA Pure) nucleic acid isolation methods in molecular diagnosis of HIV infections].

    Science.gov (United States)

    Alp, Alpaslan; Us, Dürdal; Hasçelik, Gülşen

    2004-01-01

    Rapid quantitative molecular methods are very important for the diagnosis of human immunodeficiency virus (HIV) infections, assessment of prognosis and follow up. The purpose of this study was to compare and evaluate the performances of conventional manual extraction method and automated MagNA Pure system, for the nucleic acid isolation step which is the first and most important step in molecular diagnosis of HIV infections. Plasma samples of 35 patients in which anti-HIV antibodies were found as positive by microparticule enzyme immunoassay and confirmed by immunoblotting method, were included in the study. The nucleic acids obtained simultaneously by manual isolation kit (Cobas Amplicor, HIV-1 Monitor Test, version 1.5, Roche Diagnostics) and automated system (MagNA Pure LC Total Nucleic Acid Isolation Kit, Roche Diagnostics), were amplified and detected in Cobas Amplicor (Roche Diagnostics) instrument. Twenty three of 35 samples (65.7%) were found to be positive, and 9 (25.7%) were negative by both of the methods. The agreement between the methods were detected as 91.4%, for qualitative results. Viral RNA copies detected by manual and MagNA Pure isolation methods were found between 76.0-7.590.000 (mean: 487.143) and 113.0-20.300.0000 (mean: 2.174.097) copies/ml, respectively. When both of the overall and individual results were evaluated, the number of RNA copies obtained with automatized system, were found higher than the manual method (p<0.05). Three samples which had low numbers of nucleic acids (113, 773, 857, respectively) with MagNA Pure, yielded negative results with manual method. In conclusion, the automatized MagNA Pure system was found to be a reliable, rapid and practical method for the isolation of HIV-RNA.

  11. Usefulness of in-house PCR methods for hepatitis B virus DNA detection.

    Science.gov (United States)

    Portilho, Moyra Machado; Baptista, Marcia Leite; da Silva, Messias; de Sousa, Paulo Sérgio Fonseca; Lewis-Ximenez, Lia Laura; Lampe, Elisabeth; Villar, Livia Melo

    2015-10-01

    The aim of the present study was to evaluate the performance of three in-house PCR techniques for HBV DNA detection and compare it with commercial quantitative methods to evaluate the usefulness of in-house methods for HBV diagnosis. Three panels of HBsAg reactive sera samples were evaluated: (i) 50 samples were examined using three methods for in-house qualitative PCR and the Cobas Amplicor HBV Monitor Assay; (ii) 87 samples were assayed using in-house semi-nested PCR and the Cobas TaqMan HBV test; (iii) 11 serial samples obtained from 2 HBV-infected individuals were assayed using the Cobas Amplicor HBV test and semi-nested PCR. In panel I, HBV DNA was detected in 44 samples using the Cobas Amplicor HBV test, 42 samples using semi-nested PCR (90% concordance with Cobas Amplicor), 22 samples using PCR for the core gene (63.6% concordance) and 29 samples using single-round PCR for the pre-S/S gene (75% concordance). In panel II, HBV DNA was quantified in 78 of the 87 HBsAg reactive samples using Cobas TaqMan but 52 samples using semi-nested PCR (67.8% concordance). HBV DNA was detected in serial samples until the 17th and 26th week after first donation using in-house semi-nested PCR and the Cobas Amplicor HBV test, respectively. In-house semi-nested PCR presented adequate concordance with commercial methods as an alternative method for HBV molecular diagnosis in low-resource settings. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. High-risk Human Papillomavirus Determination in Formalin-fixed, Paraffin-embedded Cervical Tissue Using the Roche Cobas 4800 System: A Comparative Study With Liquid-based Cytology.

    Science.gov (United States)

    Tardío, Juan C; Cambero, Olivia; Sánchez-Estévez, Carolina; Sánchez-García, Ana B; Angulo, Fernando; Moreno, Amalia

    2017-11-14

    Roche cobas 4800 human papillomavirus (HPV) test is an automated real-time polymerase chain reaction-based system that allows the simultaneous detection of 14 human papillomavirus high-risk (HR-HPV) genotypes. This test is Food and Drug Administration approved since 2011 for HPV determination in liquid-based cytologic samples, but a clinically validated technique for formalin-fixed, paraffin-embedded (FFPE) tissue specimens is presently not commercially available. In our laboratory, we have developed an HPV detection procedure in FFPE tissue by cobas 4800 HPV test. In order to validate our method, we retrospectively studied 165 FFPE cervical biopsy and conization specimens with varied diagnoses from our files. In 50 of them, we contrasted the results with those obtained from simultaneous liquid-based cytologies from the same patients. Finally, seeking the possible complementary clinical usefulness of the procedure, we compared the HPV genotypes detected in cervical intraepithelial neoplasia grade 1 (CIN1)-diagnosed biopsies from 20 patients with a subsequent high-grade CIN (CIN2+) diagnosis with those from another group of 20 patients without a posterior CIN2+ diagnosis. Eighty-seven percent of the assays provided informative results. HR-HPV was detected in 28 of 32 (88%) invasive cervical squamous carcinomas. Coincidental HR-HPV genotypes were obtained in 32 of 50 (64%) cases with simultaneous cervical biopsy and liquid-based cytologic samples. A significant higher risk of progression to CIN2+ was found when HPV16 (P=0.022) or any HR-HPV genotype (P=0.037) was detected in CIN1 biopsies. The reported procedure provides an automated, technically time-saving, easy to integrate into laboratory routine, and reliable method of HR-HPV determination in FFPE specimens.

  13. Nucleic acid amplification technology screening for hepatitis C virus and human immunodeficiency virus for blood donations

    International Nuclear Information System (INIS)

    Bamaga, Mohammad S.; Bokhari, Fawzi F.; Aboud, Abdulrehman M.; Al-Malki, M.; Alenzi, Faris Q.

    2006-01-01

    To investigate the performance of the commercial Roche COBAS AmpliScreen assay, and demonstrate whether the COBAS AmpliScreen human immunodeficiency virus-1 (HIV-1) test, v1.5, and COBAS AmpliScreen hepatitis C virus (HCV) v 2.0 for screening for HIV-1 and HCV RNA in the donated blood units from which plasma mini pools were collected, by nucleic acid amplification technology (NAT), could detect the positive pools and reduce the risk of transmission of infections for those routinely tested by serological assays. The study was performed on 3288 plasma samples collected from blood donors in a period of 13 months, from August 2004 to August 2005, at Al-Hada Armed Forces Hospital, Molecular Pathology Laboratory, Taif, Kingdom of Saudi Arabia. The samples were tested by the reverse transcriptase polymerase chain reaction (RT-PCR) after RNA extraction (this represents the major method in NAT assays), in parallel with the routine serological testing to detect qualitatively for HIV-1 and HCV. The NAT assays that include an automated COBAS AmpliPrep system for RNA extraction and COBAS Amplicor Analyzer using AmpliScreen kits for RT-PCR assays, and the routine serological screening assays for the detection of the HIV-1 and HCV RNA in the plasma samples from the blood donors have shown to be a reliable combination that would meet our requirements. The collected data further confirms the results from the serological assays and enables us to decrease the residual risk of transmission to a minimum with the finding of no seronegative window period donation. The results demonstrate that out of 3288 samples, the percentages of RT-PCR (NAT) negative blood donations that were also confirmed as seronegative were 99% for HCV, and 99.1% for HIV-1. The modified combined systems (automated COBAS AmpliPrep system for RNA extraction and COBAS Amplicor Analyzer using AmpliScreen kits for RT-PCR assays) for NAT screening assays has allowed the release of all blood donations supplied in the

  14. Performance of the cobas Hepatitis B virus (HBV) test using the cobas 4800 system and comparison of HBV DNA quantification ability between the COBAS AmpliPrep/COBAS TaqMan HBV test version 2.0 and cobas HBV test.

    Science.gov (United States)

    Shin, Kyung-Hwa; Lee, Hyun-Ji; Chang, Chulhun L; Kim, Hyung-Hoi

    2018-04-01

    Hepatitis B virus (HBV) DNA levels are used to predict the response to therapy, determine therapy initiation, monitor resistance to therapy, and establish treatment success. To verify the performance of the cobas HBV test using the cobas 4800 system for HBV DNA quantification and to compare the HBV DNA quantification ability between the cobas HBV test and COBAS AmpliPrep/COBAS TaqMan HBV version 2.0 (CAP/CTM v2.0). The precision, linearity, and limit of detection of the cobas HBV test were evaluated using the 4th World Health Organization International Standard material and plasma samples. Clinical samples that yielded quantitative results using the CAP/CTM v2.0 and cobas HBV tests were subjected to correlational analysis. Three hundred forty-nine samples were subjected to correlational analysis, among which 114 samples showed results above the lower limit of quantification. Comparable results were obtained ([cobas HBV test] = 1.038 × [CAP/CTM v2.0]-0.173, r = 0.914) in 114 samples, which yielded values above the lower limit of quantification. The results for 86.8% of the samples obtained using the cobas HBV test were within 0.5 log 10 IU/mL of the CAP/CTM v2.0 results. The total precision values against the low and high positive controls were 1.4% (mean level: 2.25 log 10 IU/mL) and 3.2% (mean level: 6.23 log 10 IU/mL), respectively. The cobas HBV test demonstrated linearity (1.15-6.75 log 10 IU/mL, y = 0.95 × 6 + 0.17, r 2  = 0.994). The cobas HBV test showed good correlation with CAP/CTM v2.0, and had good precision and an acceptable limit of detection. The cobas HBV test using the cobas 4800 is a reliable method for quantifying HBV DNA levels in the clinical setting. Copyright © 2018. Published by Elsevier B.V.

  15. Analytic and clinical performance of cobas HPV testing in anal specimens from HIV-positive men who have sex with men.

    Science.gov (United States)

    Wentzensen, Nicolas; Follansbee, Stephen; Borgonovo, Sylvia; Tokugawa, Diane; Sahasrabuddhe, Vikrant V; Chen, Jie; Lorey, Thomas S; Gage, Julia C; Fetterman, Barbara; Boyle, Sean; Sadorra, Mark; Tang, Scott Dahai; Darragh, Teresa M; Castle, Philip E

    2014-08-01

    Anal human papillomavirus (HPV) infections are common, and the incidence of anal cancer is high in HIV-infected men who have sex with men (MSM). To evaluate the performance of HPV assays in anal samples, we compared the cobas HPV test (cobas) to the Roche Linear Array HPV genotyping assay (LA) and cytology in HIV-infected MSM. Cytology and cobas and LA HPV testing were conducted for 342 subjects. We calculated agreement between the HPV assays and the clinical performance of HPV testing and HPV genotyping alone and in combination with anal cytology. We observed high agreement between cobas and LA, with cobas more likely than LA to show positive results for HPV16, HPV18, and other carcinogenic types. Specimens testing positive in cobas but not in LA were more likely to be positive for other markers of HPV-related disease compared to those testing negative in both assays, suggesting that at least some of these were true positives for HPV. cobas and LA showed high sensitivities but low specificities for the detection of anal intraepithelial neoplasia grade 2/3 (AIN2/3) in this population (100% sensitivity and 26% specificity for cobas versus 98.4% sensitivity and 28.9% specificity for LA). A combination of anal cytology and HPV genotyping provided the highest accuracy for detecting anal precancer. A higher HPV load was associated with a higher risk of AIN2/3 with HPV16 (P(trend) < 0.001), HPV18 (P(trend) = 0.07), and other carcinogenic types (P(trend) < 0.001). We demonstrate that cobas can be used for HPV detection in anal cytology specimens. Additional tests are necessary to identify men at the highest risk of anal cancer among those infected with high-risk HPV. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  16. Performance Evaluation of the Bioneer AccuPower® HIV-1 Quantitative RT-PCR kit: Comparison with the Roche COBAS® AmpliPrep/COBAS TaqMan® HIV-1 Test Ver.2.0 for Quantification of HIV-1 Viral Load in Indonesia.

    Science.gov (United States)

    Kosasih, Agus Susanto; Sugiarto, Christine; Hayuanta, Hubertus Hosti; Juhaendi, Runingsih; Setiawan, Lyana

    2017-08-08

    Measurement of viral load in human immunodeficiency virus type 1 (HIV-1) infected patients is essential for the establishment of a therapeutic strategy. Several assays based on qPCR are available for the measurement of viral load; they differ in sample volume, technology applied, target gene, sensitivity and dynamic range. The Bioneer AccuPower® HIV-1 Quantitative RT-PCR is a novel commercial kit that has not been evaluated for its performance. This study aimed to evaluate the performance of the Bioneer AccuPower® HIV-1 Quantitative RT-PCR kit. In total, 288 EDTA plasma samples from the Dharmais Cancer Hospital were analyzed with the Bioneer AccuPower® HIV-1 Quantitative RT-PCR kit and the Roche COBAS? AmpliPrep/COBAS® TaqMan® HIV-1 version 2.0 (CAP/CTM v2.0). The performance of the Bioneer assay was then evaluated against the Roche CAP/CTM v2.0. Overall, there was good agreement between the two assays. The Bioneer assay showed significant linear correlation with CAP/CTM v2.0 (R2=0.963, plaboratories.

  17. Human papillomavirus detection with genotyping by the cobas and Aptima assays: Significant differences in HPV 16 detection?

    Science.gov (United States)

    Chorny, Joseph A; Frye, Teresa C; Fisher, Beth L; Remmers, Carol L

    2018-03-23

    The primary high-risk human papillomavirus (hrHPV) assays in the United States are the cobas (Roche) and the Aptima (Hologic). The cobas assay detects hrHPV by DNA analysis while the Aptima detects messenger RNA (mRNA) oncogenic transcripts. As the Aptima assay identifies oncogenic expression, it should have a lower rate of hrHPV and genotype detection. The Kaiser Permanente Regional Reference Laboratory in Denver, Colorado changed its hrHPV assay from the cobas to the Aptima assay. The rates of hrHPV detection and genotyping were compared over successive six-month periods. The overall hrHPV detection rates by the two platforms were similar (9.5% versus 9.1%) and not statistically different. For genotyping, the HPV 16 rate by the cobas was 1.6% and by the Aptima it was 1.1%. These differences were statistically different with the Aptima detecting nearly one-third less HPV 16 infections. With the HPV 18 and HPV 18/45, there was a slightly higher detection rate of HPV 18/45 by the Aptima platform (0.5% versus 0.9%) and this was statistically significant. While HPV 16 represents a low percentage of hrHPV infections, it was detected significantly less by the Aptima assay compared to the cobas assay. This has been previously reported, although not highlighted. Given the test methodologies, one would expect the Aptima to detect less HPV 16. This difference appears to be mainly due to a significantly increased number of non-oncogenic HPV 16 infections detected by the cobas test as there were no differences in HPV 16 detection rates in the high-grade squamous intraepithelial lesions indicating that the two tests have similar sensitivities for oncogenic HPV 16. © 2018 Wiley Periodicals, Inc.

  18. Evaluation of clinical sensitivity and specificity of hepatitis B virus (HBV), hepatitis C virus, and human immunodeficiency Virus-1 by cobas MPX: Detection of occult HBV infection in an HBV-endemic area.

    Science.gov (United States)

    Ha, Jihye; Park, Younhee; Kim, Hyon-Suk

    2017-11-01

    Transfusion-transmitted infectious diseases remain a major concern for blood safety, particularly with hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV). Nucleic acid testing (NAT) in donor screening shortens the serologically negative window period and reduces virus transmission. The cobas MPX (Roche Molecular Systems, Inc., Branchburg, New Jersey) is a recently developed multiplex qualitative PCR system that enables the simultaneous detection of HBV, HCV, and HIV with improved sensitivity and throughput using cobas 6800 and 8800 instruments. The aim of this study was to conduct an evaluation of the clinical sensitivity and specificity of cobas MPX detection of HBV, HCV, and HIV in clinical specimens. Among samples referred for HBV, HCV, and HIV-1 quantification at Severance Hospital, Yonsei University College of Medicine, positive samples were selected to evaluate sensitivity. A total of 843 samples was tested using both cobas MPX and COBAS AmpliPrep/COBAS TaqMan Tests for HBV, HCV, and HIV-1 using the cobas 8800 system and a COBAS TaqMan 96 analyzer, respectively. Samples that showed discrepancies were confirmed by nested PCR. The cobas MPX achieved excellent sensitivity and specificity for the detection of HBV, HCV, and HIV-1 in clinical samples. We found that the lower limit of detection (LOD) of blood screening by NAT actually improves clinical sensitivity, and occult HBV infection prevalence among healthy employees of the hospital was rather high. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya.

    Science.gov (United States)

    Zeh, Clement; Ndiege, Kenneth; Inzaule, Seth; Achieng, Rebecca; Williamson, John; Chih-Wei Chang, Joy; Ellenberger, Dennis; Nkengasong, John

    2017-01-01

    Routine HIV viral load testing is not widely accessible in most resource-limited settings, including Kenya. To increase access to viral load testing, alternative sample types like dried blood spots (DBS), which overcome the logistic barriers associated with plasma separation and cold chain shipment need to be considered and evaluated. The current study evaluated matched dried blood spots (DBS) and dried plasma spots (DPS) against plasma using the Abbott M 2000 (Abbott) and Roche Cobas Ampliprep/Cobas TaqMan (CAP/CTM) quantitative viral load assays in western Kenya. Matched plasma DBS and DPS were obtained from 200 HIV-1 infected antiretroviral treatment (ART)-experienced patients attending patient support centers in Western Kenya. Standard quantitative assay performance parameters with accompanying 95% confidence intervals (CI) were assessed at the assays lower detection limit (400cps/ml for CAP/CTM and 550cps/ml for Abbott) using SAS version 9.2. Receiver operating curves (ROC) were further used to assess viral-load thresholds with best assay performance (reference assay CAP/CTM plasma). Using the Abbott test, the sensitivity and specificity, respectively, for DPS were (97.3%, [95%CI: 93.2-99.2] and 98.1% [95%CI: 89.7-100]) and those for DBS (93.9% [95%CI: 88.8-97.2] and 88.0% [95%CI: 82.2-92.4]). The correlation and agreement using paired plasma and DPS/DBS were strong, with r2 = 90.5 and rc = 68.1. The Bland-Altman relative percent change was 95.3 for DPS, (95%CI: 90.4-97.7) and 73.6 (95%CI: 51.6-86.5) for DBS. Using the CAP/CTM assay, the sensitivity for DBS was significantly higher compared to DPS (100.0% [95% CI: 97.6-100.0] vs. 94.7% [95%CI: 89.8-97.7]), while the specificity for DBS was lower: 4%, [95% CI: 0.4-13.7] compared to DPS: 94.0%, [95% CI: 83.5-98.7]. When compared under different clinical relevant thresholds, the accuracy for the Abbott assay was 95% at the 1000cps/ml cut-off with a sensitivity and specificity of 96.6% [95% CI 91.8-98.7] and 90

  20. Fluorimetric methods for the measurement of intermediate metabolites (lactate, pyruvate, alanine, beta-hydroxybutyrate, glycerol) using a COBAS FARA centrifugal analyser.

    Science.gov (United States)

    Monti, L D; Sandoli, P E; Costa, S; Phan, V C; Piatti, P M

    1993-01-01

    Intermediate products of the metabolism of glucose, fat and amino-acid are important in the evaluation of such metabolic disorders as diabetes mellitus, liver disease and metabolic acidosis. In the present study, methods for the measurement of intermediate metabolites (lactate, pyruvate, alanine, beta-hydroxybutyrate and glycerol) have been adapted to a fast centrifugal analyzer: the COBAS FARA. Correlation coeffcients rangedfrom 0.90 to 0.99, compared to established manual spectrophotometric methods. Within-run coeffcients of variation (CVs) ranged between 2.9 and 8.8% at low levels, between 1.5 and 5.7% at medium levels and between 1.2 and 5.6% at high levels. Between-run CVs were between 4.0 and 15.0% at low levels, between 1.7 and 7.0% at medium levels and between 1.3 and 2.7% at high levels. These fluorimetric assays for the determination of intermediate metabolites on COBAS FARA (Roche) have a good sensitivity and precision, are less costly than manual methods and can be used on a routine basis.

  1. Hepatitis C virus detection in the semen of infected patients

    Directory of Open Access Journals (Sweden)

    Norma de Paula Cavalheiro

    Full Text Available Though HCV infection is a serious public health problem, some aspects of its biology are still not well understood, such as its transmission through seminal fluid and sexual transmission. We looked for HCV in the semen of infected patients. Thirteen patients were included. Semen fractions (seminal plasma, leukocytes and spermatozoa were separated with 45% and 90% Percoll gradients. The HCV-RNA in blood and semen fractions was extracted using the same protocol (AMPLICOR Roche and was detected using the qualitative Roche Amplicor test and by agarose gel electrophoresis, with ethidium bromide staining. The mean age of the patients was 40.7 years. Risk factors for the acquisition of HCV included injectable and inhaled drug use in six (42.8%, blood transfusion in four (28.6%, and no risk factors in four (28.6% patients. Genotype 1 was detected in 62% of the patients, followed by genotype 3 in 23% and genotype 2 in 15%. All blood samples were positive, regardless of the technique used for detection. All semen samples identified by Roche Amplicor and analyzed by agarose gel electrophoresis were negative. Among the 52 semen samples (total and fractions identified by the Roche Amplicor method, 45 (87% were inhibited. A negative result was recorded for one (1.9% total semen sample, one (1.9% leukocyte and four (7.7% seminal plasma fractions. Only one (1.9% sample of the spermatozoon fraction was positive. The results obtained suggested false-negative reactions for the semen samples.

  2. Benefit of Hepatitis C Virus Core Antigen Assay in Prediction of Therapeutic Response to Interferon and Ribavirin Combination Therapy

    OpenAIRE

    Takahashi, Masahiko; Saito, Hidetsugu; Higashimoto, Makiko; Atsukawa, Kazuhiro; Ishii, Hiromasa

    2005-01-01

    A highly sensitive second-generation hepatitis C virus (HCV) core antigen assay has recently been developed. We compared viral disappearance and first-phase kinetics between commercially available core antigen (Ag) assays, Lumipulse Ortho HCV Ag (Lumipulse-Ag), and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor test, version 2 (Amplicor M), to estimate the predictive benefit of a sustained viral response (SVR) and non-SVR in 44 genotype 1b patients treated with interferon (IFN) ...

  3. Prevalence of human papillomavirus in 5,072 consecutive cervical SurePath samples evaluated with the Roche cobas HPV real-time PCR assay

    DEFF Research Database (Denmark)

    Preisler, Sarah; Rebolj, Matejka; Untermann, Anette

    2013-01-01

    of the present study, Horizon, was to assess the prevalence of high-risk HPV infections in an area with a high background risk of cervical cancer, where women aged 23-65 years are targeted for cervical screening. We collected 6,258 consecutive cervical samples from the largest cervical screening laboratory......-29 years and 10% in women aged 60-65 years. HC2 assay was positive in 20% of samples, and cytology was abnormal (≥ atypical squamous cells of undetermined significance) for 7% samples. When only samples without recent abnormalities were taken into account, 24% tested positive on cobas, 19% on HC2, and 5...

  4. Detection of PCR inhibitors in cervical specimens by using the AMPLICOR Chlamydia trachomatis assay

    NARCIS (Netherlands)

    R.P.A.J. Verkooyen (Roel); A. Luijendijk (Ad); W.M. Huisman; W.H.F. Goessens (Wil); J.A.J.W. Kluytmans (Jan); J.H. van Rijsoort-Vos; H.A. Verbrugh (Henri)

    1996-01-01

    textabstractTo determine that susceptibility of AMPLICOR Chlamydia trachomatis PCR to inhibitory factors possibly present in cervical specimens, we obtained cervical specimens from 200 gynecology patients attending our outpatient clinic. The prevalence of C. trachomatis

  5. Evaluation of the Ortho-Clinical Diagnostics Vitros ECi Anti-HCV test: comparison with three other methods.

    Science.gov (United States)

    Watterson, Jeannette M; Stallcup, Paulina; Escamilla, David; Chernay, Patrick; Reyes, Alfred; Trevino, Sylvia C

    2007-01-01

    After observing a high incidence of low positive hepatitis C virus (HCV) antibody screens by the Ortho-Clinical Vitros ECi test (Orthoclinical Diagnostics, Raritan, NJ), we compared results against those obtained using another chemiluminescent analyzer, as well as two U.S. Food and Drug Administration (FDA)-approved confirmatory methodologies. To ascertain the true anti-HCV status of samples deemed low-positive by the Ortho-Clinical Vitros ECi test, we tested samples using the ADVIA Centaur HCV screen test (Siemens Medical Solutions Diagnostics), the Chiron recombinant immunoblot assay (RIBA) test (Chiron Corp., Emeryville, CA), and the Roche COBAS Amplicor HCV qualitative test (Roche Diagnostics, Indianapolis, IN) in a series of studies. Of 94 specimens positive by Vitros ECi, 19% were observed to be negative by Centaur. A separate study of 91 samples with signal-to-cutoff (s/co) values less than 8.0 showed that all but one was negative for HCV ribonucleic acid (RNA). In comparison with RIBA, 100% (77) samples positive by the Vitros ECi test with s/co values less than 12.0 were negative or indeterminate by RIBA. A final study comparing all four methods side-by-side showed 63% disagreement by Centaur for Vitros ECi low-positive samples, 75% disagreement by RIBA, and 97% disagreement by polymerase chain reaction (PCR). In conclusion, the Ortho-Clinical Vitros ECi Anti-HCV test yields a high rate of false-positive results in the low s/co range in our patient population. (c) 2007 Wiley-Liss, Inc.

  6. Use of Molecular Assays in Diagnosis and Monitoring of Cytomegalovirus Disease following Renal Transplantation

    OpenAIRE

    Aitken, Celia; Barrett-Muir, Winsome; Millar, Colin; Templeton, Kate; Thomas, Janice; Sheridan, Fran; Jeffries, Donald; Yaqoob, Magdi; Breuer, Judith

    1999-01-01

    We compared two commercial molecular assays (the Murex Hybrid Capture CMV DNA assay [HCA], version 2, and the Roche Amplicor plasma PCR assay) with a standard shell vial assay in detecting and predicting cytomegalovirus (CMV) disease in a group of renal transplant patients and assessed the role of viral load measurements (using the HCA) in their management. The sensitivity of the HCA and Amplicor assay in terms of disease detection was 100%, compared to 71% for the shell vial assay. Both the ...

  7. Evaluation of the Hologic gen-probe PANTHER, APTIMA Combo 2 assay in a tertiary care teaching hospital.

    Science.gov (United States)

    Cheng, Annie; Kirby, James E

    2014-03-01

    To evaluate the performance of the Hologic Gen-Probe (San Diego, CA) PANTHER system. The performance of PANTHER was compared with the Hologic Gen-Probe TIGRIS and/or Roche (Indianapolis, IN) COBAS AMPLICOR systems through testing of patient specimens and the spiked-urine matrix. After discrepant resolution, PANTHER demonstrated a 99.3% (95% confidence interval [CI], 96.0%-99.9%) positive and 100% (98.5%-100.0%) negative agreement for Chlamydia trachomatis (CT) and 100% (96.6%-100.0%) positive and 100% (98.6%-100.0%) negative agreement for Neisseria gonorrhoeae (NG) for all male, female, unsexed, and NG-spiked female urine specimens combined. For other specimen types collectively, the PANTHER demonstrated 100% (95% CI, 90.6%-100.0%) positive and 100% (88.3%-100.0%) negative agreement for CT and 90.9% (62.8%-98.4%) positive and 100% (93.5%-100.0%) negative agreement for NG. Analytical sensitivity of the PANTHER in urine matrix was similar to the TIGRIS system. The PANTHER system provides an excellent new addition to options for detecting CT and NG, is appropriate for testing urine samples, and will facilitate high-throughput testing in the clinical laboratory.

  8. Results of the Abbott RealTime HIV-1 assay for specimens yielding "target not detected" results by the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test.

    Science.gov (United States)

    Babady, N Esther; Germer, Jeffrey J; Yao, Joseph D C

    2010-03-01

    No significantly discordant results were observed between the Abbott RealTime HIV-1 assay and the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test (CTM) among 1,190 unique clinical plasma specimens obtained from laboratories located in 40 states representing all nine U.S. geographic regions and previously yielding "target not detected" results by CTM.

  9. Routine screening of blood donations at Qingdao central blood bank, China, for hepatitis B virus (HBV) DNA with a real-time, multiplex nucleic acid test for HBV, hepatitis C virus, and human immunodeficiency virus Types 1 and 2.

    Science.gov (United States)

    Yang, Zhongsi; Xu, Lei; Liu, Li; Feng, Qiuxia; Zhang, Longmu; Ma, Weijuan; Saldanha, John; Wang, Mingmin; Zhao, Lin

    2013-10-01

    The Roche cobas TaqScreen MPX test was used to evaluate the rate of hepatitis B surface antigen (HBsAg)-negative donations that were hepatitis B virus (HBV) DNA reactive from June 2010 to January 2011 in Qingdao, China. HBsAg-negative samples from 65,800 voluntary blood donors were tested with the cobas TaqScreen MPX test in pools of 6 on the Roche cobas s 201 blood screening platform. Samples positive for HBV DNA and negative for HBsAg were quantitated with the Roche COBAS AmpliPrep/COBAS TaqMan HBV test. In addition, serologic tests for HBsAg, hepatitis B surface antibody, anti-hepatitis B core antigen (anti-HBc), anti-hepatitis B e antigen (anti-HBe), and hepatitis B e antigen (HBe) were done using the Roche electrochemiluminescence immunoassay. A total of 80 nucleic acid amplification technology (NAT) test-reactive pools were identified and 59 pools (74%) resolved to a reactive sample. All samples were HBV DNA reactive and the viral load in each sample was quantitated. The viral loads of the samples ranged from less than 20 to 34,600 IU/mL; 13 samples (22%) had viral loads of more than 20 IU/mL, 27 samples (45.8%) had viral loads of less than 20 IU/mL, and 19 samples (32.2%) had undetectable viral loads. Of the 59 NAT-reactive samples, 40 (67.8%) were anti-HBc positive. Fifteen of the 59 samples could not be confirmed as NAT reactive either by an alternative NAT test or by serology. The HBV NAT yield in blood donors in Qingdao is 0.06% (38/65,800). This study confirmed the value of NAT for interdicting HBV-positive donations and preventing transfusion-transmitted HBV infections. © 2013 American Association of Blood Banks.

  10. Results of the Abbott RealTime HIV-1 Assay for Specimens Yielding “Target Not Detected” Results by the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test▿

    OpenAIRE

    Babady, N. Esther; Germer, Jeffrey J.; Yao, Joseph D. C.

    2009-01-01

    No significantly discordant results were observed between the Abbott RealTime HIV-1 assay and the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test (CTM) among 1,190 unique clinical plasma specimens obtained from laboratories located in 40 states representing all nine U.S. geographic regions and previously yielding “target not detected” results by CTM.

  11. Comparison of the cobas Human Papillomavirus (HPV) Test with the Hybrid Capture 2 and Linear Array HPV DNA Tests

    Science.gov (United States)

    Sadorra, Mark; LaMere, Brandon J.; Kail, Randi; Aldrich, Carrie; Kinney, Walter; Fetterman, Barbara; Lorey, Thomas; Schiffman, Mark; Castle, Philip E.

    2012-01-01

    The cobas human papillomavirus (HPV) test (cobas) was recently approved by the U.S. Food and Drug Administration (FDA) and identifies HPV16 and HPV18 separately as well as detecting a pool of 11 HR-HPV genotypes (HPV31, -33, -35, -39, -45, -51, -52, -56, -58, -59, -68) and also HPV66. We compared cobas, Linear Array (LA), and Hybrid Capture 2 (HC2) assays for detection of carcinogenic HPV DNA, and cobas and LA for detection of HPV16 and HPV18 DNA, among the first 1,852 women enrolled in the HPV Persistence and Progression Cohort (PaP Cohort) study. Specimens were tested by all 3 assays 1 year after an HC2-positive result. In 1,824 specimens with cobas results, cobas had an 85.9% agreement with HC2 and 91.0% agreement with LA for carcinogenic HPV detection. When results between cobas and HC2 disagreed, cobas tended to call more women HPV positive (P < 0.01). Categorizing cobas and LA results hierarchically according to cancer risk (HPV16, HPV18, other carcinogenic HPV genotypes, or carcinogen negative), there was a 90% agreement for all categories of HPV (n = 1,824). We found good agreement between the two U.S. FDA-approved HPV tests, with discrepancies between the two assays due to specific characteristics of the individual assays. Additional studies are needed to compare HC2 and cobas for detecting and predicting CIN3 to understand the clinical implications of the discrepant test results between the two tests. PMID:22075592

  12. The evaluation of Recombinant Immunoblot assay (RIBA and HCV-RNA test results in patients with low titer Anti-HCV positivity

    Directory of Open Access Journals (Sweden)

    Berrin Uzun

    2014-12-01

    Full Text Available Objectives: Laboratory diagnosis of hepatitis C virus (HCV infection is based on the detection of anti-HCV antibodies by enzyme immunoassay (EIA or chemiluminescence immunoassay (CIA techniques. However, a consensus related to the problem of low titer (Serum/Cut-off; S/C= 1.0 anti-HCV antibodies is still lacking. The study attempts to evaluate the clinical status of the patients with low titer anti-HCV antibodies detected by third generation anti-HCV tests during February 2013- May 2014 retrospectively. Methods: Serum samples were studied by Advia Centaur XP autoanalyser (Bayer-Siemens, Germany for anti-HCV, and line immunoassay (Inno-LIATM HCV Score, İnnogenetics, Belgium for anti-HCV confirmatory test, Cobas AmpliPre/Cobas AMPLICOR HCV Test (Roche diagnostics, Switzerland for HCV RNA. Results: A total of 55.631 serum samples were studied, and 55 of them were anti-HCV positive of which with low antibody levels (sample/cutoff [S/CO]. S/CO values ranged from 1.15 to 6.15. Seventeen (31% of patients who have low antibody levels were defined as positive and 2 (4% patients were intermittent and 36 (65% patients were negative with line immunoassay. HCV-RNA was not detected in any of the samples. Conclusions: It is thought that antibody positivity must be verified in cases of recurrent reactivity when considering the cost-effectiveness of molecular tests. In the study was concluded that the use of molecular tests would be appropriate diagnosis, and the effectiveness of treatment if necessary after evaluation of patients with biochemical analysis. J Clin Exp Invest 2014; 5 (4: 553-556

  13. NT-proBNP on Cobas h 232 in point-of-care testing

    DEFF Research Database (Denmark)

    Gils, Charlotte; Ramanathan, R.; Breindahl, T.

    2015-01-01

    Background. NT-proBNP may be useful for ruling out heart failure in primary health care. In this study we examined the analytical quality of NT-proBNP in primary health care on the Cobas h 232 point-of-care instrument compared with measurements performed in a hospital laboratory. Materials...... and methods. Blood samples requested for NT-proBNP were collected in primary health care (n = 95) and in a hospital laboratory (n = 107). NT-proBNP was measured on-site on Cobas h 232 instruments both in primary health care centres and at the hospital laboratory and all samples were also analyzed...... with a comparison method at the hospital. Precision, trueness, accuracy, and lot-variation were determined at different concentration levels and evaluated according to acceptance criteria. Furthermore user-friendliness was assessed by questionnaires. Results. For Cobas h 232 repeatability CV was 8...

  14. Linnugripp tõi ravimifirmale Roche magusa kasumi / Erik Aru

    Index Scriptorium Estoniae

    Aru, Erik

    2005-01-01

    Šveitsi ravimitootja Roche'i viiruseravimi Tamiflu müük on kasvanud. Roche kavatseb järgmiseks suveks suurendada toodangut võrreldes 2004. aastaga kaheksa korda, kuid seda ei peeta piisavaks. ÜRO ja WHO nõuavad, et firma loobuks patentidest või annaks koopiaravimite valmistajatele tootmise litsentsi. Tabel: F. Hoffmann-La Roche. Lisa: Linnugripi vaktsiini võib loota kuue kuu pärast

  15. [Evolution of residual risk for HIV, HCV and HBV, from 1999 to 2010, in blood donations of the Centro Hospitalar S. João, EPE, Porto, Portugal].

    Science.gov (United States)

    Koch, Carmo; Araújo, Fernando

    2013-01-01

    Monitoring the residual risk of transfusion-transmitted viral infections is important to evaluate the improvement achieved in the blood donation safety and to adopt policies to reduce risks. The present study calculates the incidence of the key infectious diseases, human immunodeficiency virus (HIV), hepatitis B virus (HBV) and hepatitis C virus (HCV) as well as the residual risk of transfusion-transmitted viral infections, during twelve years, 1999 through 2010. Data were analyzed over 3 periods of 4 years (1999-2002, 2003-2006 and 2007-2010). The risk estimates were compared to those previously obtained for blood donations occurred between 1991 and 1998. The study included 209 640 blood donations, from 42 634 regular, volunteers and unpaid donors. The residual risk of transfusion-transmitted infection per million donations was calculated, for each virus, through mathematical model "Incidence rate/window period", described by Schreiber et al. All donations were screened according to Portuguese legislation. In January 2001, the nucleic acid testing in minipool was implemented on all blood donations, for screening simultaneously HIV-1 and HCV ribonucleic acid (RNA) (Cobas Amplicor Ampliscreen-Roche©). This test was replaced, in January 2007, by the simultaneous screening of HBV deoxyribonucleic acid, HCV RNA and HIV-1/HIV-2 RNA, in minipool (Cobas Taqscreen MPX Test-Roche©). The residual risk of transmitting viral infections during the transfusion of blood components is very small and has declined over the years. After the implementation of the nucleic acid testing in minipool for the three viruses, the risk of giving blood during an infectious window period was estimated as follows: for human immunodeficiency virus, 1 in 1.67 million, for hepatitis C virus 1 in 3.33 million and for hepatitis B virus 1 in 526 000. During the 12 years under study, we found a decrease in residual risk for the three viruses, by a factor around five for human immunodeficiency virus

  16. The cobas p 630 instrument: a dedicated pre-analytic solution to optimize COBAS® AmpliPrep/COBAS® TaqMan® system workflow and turn-around-time.

    Science.gov (United States)

    Vallefuoco, L; Sorrentino, R; Spalletti Cernia, D; Colucci, G; Portella, G

    2012-12-01

    The cobas p 630, a fully automated pre-analytical instrument for primary tube handling recently introduced to complete the Cobas(®) TaqMan systems portfolio, was evaluated in conjunction with: the COBAS(®) AmpliPrep/COBAS(®) TaqMan HBV Test, v2.0, COBAS(®) AmpliPrep/COBAS(®) TaqMan HCV Test, v1.0 and COBAS(®) AmpliPrep/COBAS(®) TaqMan HIV Test, v2.0. The instrument performance in transferring samples from primary to secondary tubes, its impact in improving COBAS(®) AmpliPrep/COBAS(®) TaqMan workflow and hands-on reduction and the risk of possible cross-contamination were assessed. Samples from 42 HBsAg positive, 42 HCV and 42 HIV antibody (Ab) positive patients as well as 21 healthy blood donors were processed with or without automated primary tubes. HIV, HCV and HBsAg positive samples showed a correlation index of 0.999, 0.987 and of 0.994, respectively. To assess for cross-contamination, high titer HBV DNA positive samples, HCV RNA and HIV RNA positive samples were distributed in the cobas p 630 in alternate tube positions, adjacent to negative control samples within the same rack. None of the healthy donor samples showed any reactivity. Based on these results, the cobas p 630 can improve workflow and sample tracing in laboratories performing molecular tests, and reduce turnaround time, errors, and risks. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Performance evaluation of the Cobas TaqMan MTB assay on respiratory specimens according to clinical application

    Directory of Open Access Journals (Sweden)

    Jong Eun Park

    2017-11-01

    Full Text Available Objective: To evaluate the performance of the Cobas TaqMan MTB assay (Cobas assay with respect to its clinical application. Methods: This was a retrospective analysis of 1154 results from 1034 patients for whom mycobacterial cultures and the Cobas assay were performed simultaneously. Based on the patient medical records, two categories of clinical application were defined: (1 the diagnosis of patients with a high probability of pulmonary tuberculosis according to clinical and radiological features (n = 128, and (2 the exclusion of tuberculosis in clinically indeterminate patients (n = 1026. Standard culture was used as the reference method. Results: The sensitivity of the Cobas assay for the detection of Mycobacterium tuberculosis was 70.4% (95% confidence interval (CI 49.7–85.5% for category 1, but only 25.0% (95% CI 4.5–64.4% for category 2. The specificity was ≥95.0% for both categories. The positive predictive value was 79.2% (95% CI 57.3–92.1% for category 1 and 33.3% (95% CI 6.0–75.9% for category 2, while the negative predictive value was 92.3% (95% CI 85.0–96.4% for category 1 and 99.4% (95% CI 98.7–99.8% for category 2. Conclusions: The results of this study indicate that Cobas assay results must be interpreted carefully according to the clinical purpose of the assay. Keywords: Mycobacterium tuberculosis, Pulmonary tuberculosis, Cobas TaqMan MTB assay, Korea

  18. Analytical performances of the Diazyme ADA assay on the Cobas® 6000 system.

    Science.gov (United States)

    Delacour, Hervé; Sauvanet, Christophe; Ceppa, Franck; Burnat, Pascal

    2010-12-01

    To evaluate the analytical performance of the Diazyme ADA assay on the Cobas® 6000 system for pleural fluid samples analysis. Imprecision, linearity, calibration curve stability, interference, and correlation studies were completed. The Diazyme ADA assay demonstrated excellent precision (CVADA assay correlated well with the Giusti method (r(2)=0.93) but exhibited a negative bias (~ -30%). The Diazyme ADA assay on the Cobas® 6000 system represents a rapid, accurate, precise and reliable method for determination of ADA activity in pleural fluid samples. Copyright © 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Lab-in-a-tube: Real-time molecular point-of-care diagnostics for influenza A and B using the cobas(R) Liat(R) system

    NARCIS (Netherlands)

    Melchers, W.J.G.; Kuijpers, J; Sickler, J.J.; Rahamat-Langendoen, J.C.

    2017-01-01

    Rapid diagnosis of influenza A and B is important for direct treatment decisions in patient care and for the reduction of in-hospital transmissions. The new real-time PCR based molecular point-of-care (POC) assay, the cobas(R) Influenza A/B test on the cobas(R) Liat(R) System (cobas(R) Liat(R)

  20. Genotype 3 is the predominant hepatitis C genotype in a multi-ethnic Asian population in Malaysia.

    Science.gov (United States)

    Ho, Shiaw-Hooi; Ng, Kee-Peng; Kaur, Harvinder; Goh, Khean-Lee

    2015-06-01

    Genotypes of hepatitis C virus (HCV) are distributed differently across the world. There is a paucity of such data in a multi-ethnic Asian population like Malaysia. The objectives of this study were to determine the distribution of HCV genotypes between major ethnic groups and to ascertain their association with basic demographic variables like age and gender. This was a cross-sectional prospective study conducted from September 2007 to September 2013. Consecutive patients who were detected to have anti-HCV antibodies in the University of Malaya Medical Centre were included and tested for the presence of HCV RNA using Roche Cobas Amplicor Analyzer and HCV genotype using Roche single Linear Array HCV Genotyping strip. Five hundred and ninety-six subjects were found to have positive anti-HCV antibodies during this period of time. However, only 396 (66.4%) were HCV RNA positive and included in the final analysis. Our results showed that HCV genotype 3 was the predominant genotype with overall frequency of 61.9% followed by genotypes 1 (35.9%), 2 (1.8%) and 6 (0.5%). There was a slightly higher prevalence of HCV genotype 3 among the Malays when compared to the Chinese (P=0.043). No other statistical significant differences were observed in the distribution of HCV genotypes among the major ethnic groups. There was also no association between the predominant genotypes and basic demographic variables. In a multi-ethnic Asian society in Malaysia, genotype 3 is the predominant genotype among all the major ethnic groups with genotype 1 as the second commonest genotype. Both genotypes 2 and 6 are uncommon. Neither genotype 4 nor 5 was detected. There is no identification of HCV genotype according to ethnic origin, age and gender.

  1. Detection and identification of occult HBV in blood donors in Taiwan using a commercial, multiplex, multi-dye nucleic acid amplification technology screening test.

    Science.gov (United States)

    Lin, K T; Chang, C L; Tsai, M H; Lin, K S; Saldanha, J; Hung, C M

    2014-02-01

    The ability of a new generation commercial, multiplex, multi-dye test from Roche, the cobas TaqScreen MPX test, version 2.0, to detect and identify occult HBV infections was evaluated using routine donor samples from Kaohsiung Blood Bank, Taiwan. A total of 5973 samples were tested by nucleic acid amplification technology (NAT); 5898 in pools of six, 66 in pools of less than six and nine samples individually. NAT-reactive samples were retested with alternative NAT tests, and follow-up samples from the donors were tested individually by NAT and for all the HBV serological markers. Eight NAT-only-reactive donors were identified, and follow-up samples were obtained from six of the donors. The results indicated that all eight donors had an occult HBV infection with viral loads <12 IU/ml. The cobas(®) TaqScreen MPX test, version 2.0, has an advantage over the current Roche blood screening test, the cobas TaqScreen MPX test, for screening donations in countries with a high prevalence of occult HBV infections since the uncertainty associated with identifying samples with very low viremia is removed by the ability of the test to identify the viral target in samples that are reactive with the cobas TaqScreen MPX test, version 2.0. © 2013 International Society of Blood Transfusion.

  2. High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas® CT/NG.

    Science.gov (United States)

    Marlowe, Elizabeth M; Hardy, David; Krevolin, Mark; Gohl, Peter; Bertram, Alexander; Arcenas, Rodney; Seiverth, Britta; Schneider, Tanja; Liesenfeld, Oliver

    2017-09-01

    We compared the analytical and clinical performance of cobas ® CT/NG for use on the Cobas ® 6800/8800 Systems with the Cobas ® 4800 CT/NG Test from urogenital and extragenital specimens in over 12,000 specimens from both male and female subjects in Germany and the United States. The analytical sensitivity was ≤40 EB/ml for Chlamydia trachomatis (CT) and ≤1 CFU/ml for Neisseria gonorrhoeae (NG). Using clinical specimens, the overall percent agreement with the Cobas ® 4800 CT/NG Test was >98.5%. Across urogenital specimens, there were 93 discrepant specimens; 76 (93.8%) of 81 CT discrepant specimens were 6800+/4800- and 10 (83.3%) of 12 NG discrepant specimens were 6800+/4800-. Sequencing verified CT results for 45 (61.6%) of 73 samples positive by 6800 and 1 (20%) of 5 positive by 4800. Similarly, 7 (70.0%) of 10 NG samples positive by 6800 and 1 of 2 positive by 4800 were confirmed by sequencing. Among discrepant extragenital specimens (all 6800+/4800-), 7 (50%) of 14 oropharyngeal and 23 (76.7%) of 30 anorectal CT discordant samples were confirmed as CT positive by sequencing; all 8 anorectal and 20 (90.9%) of 22 oropharyngeal NG discordant results were also confirmed as NG positive. In conclusion, Cobas ® CT/NG for use on the Cobas ® 6800/8800 Systems provides high-throughput automated solutions for sexually transmitted infection (STI) screening programs.

  3. COMPOSITIONS AND ORIGINS OF OUTER PLANET SYSTEMS: INSIGHTS FROM THE ROCHE CRITICAL DENSITY

    International Nuclear Information System (INIS)

    Tiscareno, Matthew S.; Hedman, Matthew M.; Burns, Joseph A.; Castillo-Rogez, Julie

    2013-01-01

    We consider the Roche critical density (ρ Roche ), the minimum density of an orbiting object that, at a given distance from its planet, is able to hold itself together by self-gravity. It is directly related to the more familiar ''Roche limit,'' the distance from a planet at which a strengthless orbiting object of given density is pulled apart by tides. The presence of a substantial ring requires that transient clumps have an internal density less than ρ Roche . Conversely, in the presence of abundant material for accretion, an orbiting object with density greater than ρ Roche will grow. Comparing the ρ Roche values at which the Saturn and Uranus systems transition rapidly from disruption-dominated (rings) to accretion-dominated (moons), we infer that the material composing Uranus' rings is likely more rocky, as well as less porous, than that composing Saturn's rings. From the high values of ρ Roche at the innermost ring moons of Jupiter and Neptune, we infer that those moons may be composed of denser material than expected, or more likely that they are interlopers that formed farther from their planets and have since migrated inward, now being held together by internal material strength. Finally, the ''Portia group'' of eight closely packed Uranian moons has an overall surface density similar to that of Saturn's A ring. Thus, it can be seen as an accretion-dominated ring system, of similar character to the standard ring systems except that its material has a characteristic density greater than the local ρ Roche .

  4. Benefit of hepatitis C virus core antigen assay in prediction of therapeutic response to interferon and ribavirin combination therapy.

    Science.gov (United States)

    Takahashi, Masahiko; Saito, Hidetsugu; Higashimoto, Makiko; Atsukawa, Kazuhiro; Ishii, Hiromasa

    2005-01-01

    A highly sensitive second-generation hepatitis C virus (HCV) core antigen assay has recently been developed. We compared viral disappearance and first-phase kinetics between commercially available core antigen (Ag) assays, Lumipulse Ortho HCV Ag (Lumipulse-Ag), and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor test, version 2 (Amplicor M), to estimate the predictive benefit of a sustained viral response (SVR) and non-SVR in 44 genotype 1b patients treated with interferon (IFN) and ribavirin. HCV core Ag negativity could predict SVR on day 1 (sensitivity = 100%, specificity = 85.0%, accuracy = 86.4%), whereas RNA negativity could predict SVR on day 7 (sensitivity = 100%, specificity = 87.2%, accuracy = 88.6%). None of the patients who had detectable serum core Ag or RNA on day 14 achieved SVR (specificity = 100%). The predictive accuracy on day 14 was higher by RNA negativity (93.2%) than that by core Ag negativity (75.0%). The combined predictive criterion of both viral load decline during the first 24 h and basal viral load was also predictive for SVR; the sensitivities of Lumipulse-Ag and Amplicor-M were 45.5 and 47.6%, respectively, and the specificity was 100%. Amplicor-M had better predictive accuracy than Lumipulse-Ag in 2-week disappearance tests because it had better sensitivity. On the other hand, estimates of kinetic parameters were similar regardless of the detection method. Although the correlations between Lumipulse-Ag and Amplicor-M were good both before and 24 h after IFN administration, HCV core Ag seemed to be relatively lower 24 h after IFN administration than before administration. Lumipulse-Ag seems to be useful for detecting the HCV concentration during IFN therapy; however, we still need to understand the characteristics of the assay.

  5. Comparison of cobas HCV GT against Versant HCV Genotype 2.0 (LiPA) with confirmation by Sanger sequencing.

    Science.gov (United States)

    Yusrina, Falah; Chua, Cui Wen; Lee, Chun Kiat; Chiu, Lily; Png, Tracy Si-Yu; Khoo, Mui Joo; Yan, Gabriel; Lee, Guan Huei; Yan, Benedict; Lee, Hong Kai

    2018-05-01

    Correct identification of infecting hepatitis C virus (HCV) genotype is helpful for targeted antiviral therapy. Here, we compared the HCV genotyping performance of the cobas HCV GT assay against the Versant HCV Genotype 2.0 (LiPA) assay, using 97 archived serum samples. In the event of discrepant or indeterminate results produced by either assay, the core and NS5B regions were sequenced. Of the 97 samples tested by the cobas, 25 (26%) were deemed indeterminate. Sequencing analyses confirmed 21 (84%) of the 25 samples as genotype 6 viruses with either subtype 6m, 6n, 6v, 6xa, or unknown subtype. Of the 97 samples tested by the LiPA, thirteen (13%) were deemed indeterminate. Seven (7%) were assigned with genotype 1, with unavailable/inconclusive results from the core region of the LiPA. Notably, the 7 samples were later found to be either genotype 3 or 6 by sequencing analyses. Moreover, 1 sample by the LiPA was assigned as genotypes 4 (cobas: indeterminate) but were later found to be genotype 3 by sequencing analyses, highlighting its limitation in assigning the correct genotype. The cobas showed similar or slightly higher accuracy (100%; 95% CI 94-100%) compared to the LiPA (99%; 95% CI 92-100%). Twenty-six percent of the 97 samples tested by the cobas had indeterminate results, mainly due to its limitation in identifying genotype 6 other than subtypes 6a and 6b. This presents a significant assay limitation in Southeast Asia, where genotype 6 infection is highly prevalent. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Validation of Method Performance of pH, PCO2, PO2, Na(+), K(+) of Cobas b121 ABG Analyser.

    Science.gov (United States)

    Nanda, Sunil Kumar; Ray, Lopamudra; Dinakaran, Asha

    2014-06-01

    The introduction of a new method or new analyser is a common occurrence in clinical biochemistry laboratory. Blood gas measurements and electrolytes are often performed in Point-of-Care (POC) settings. When a new POC analyser is obtained, the performance of the analyser should be evaluated by comparison to the measurements with the reference analyser in the laboratory. Evaluation of method performance of pH, PCO2, PO2, Na(+), K(+) of cobas b121 ABG analyser. The evaluation of method performance of pH, PO2, PCO2, Na(+), K(+) of cobas b121 ABG analyser was done by comparing the results of 50 patient samples run on cobas b121 with the results obtained from Rapid lab values (reference analyser). Correlation coefficient was calculated from the results obtained from both the analysers. Precision was calculated by running biorad ABG control samples. The correlation coefficient values obtained for parameters were close to 1.0 indicating good correlation. The CV obtained for all the parameters were less than 5 indicating good precision. The new ABG analyser, Cobas b121 correlated well with the reference ABG analyser (Rapid Lab) and could be used to run on patient samples.

  7. Hybrid Capture 2 and cobas human papillomavirus assays perform similarly on SurePath samples from women with abnormalities

    DEFF Research Database (Denmark)

    Fornari, D; Rebolj, M; Bjerregaard, B

    2016-01-01

    OBJECTIVE: In two laboratories (Departments of Pathology, Copenhagen University Hospitals of Herlev and Hvidovre), we compared cobas and Hybrid Capture 2 (HC2) human papillomavirus (HPV) assays using SurePath® samples from women with atypical squamous cells of undetermined significance (ASCUS......) at ≥30 years and women after treatment of cervical intraepithelial neoplasia (CIN). METHODS: Samples from 566 women with ASCUS and 411 women after treatment were routinely tested with HC2 and, thereafter, with cobas. Histological outcomes were retrieved from the Danish Pathology Data Base. We calculated...... the overall agreement between the assays, and compared their sensitivity and specificity for ≥CIN2. RESULTS: In women with ASCUS, HC2 and cobas testing results were similar in the two laboratories. The overall agreement was 91% (95% CI, 88-93). After CIN treatment, the overall agreement was 87% (95% CI, 82...

  8. Roche-Lobe overflow in X-ray binaries, ch. 2

    International Nuclear Information System (INIS)

    Savonije, G.J.

    1977-01-01

    It is examined whether Roche-lobe overflow can be the main mechanism of mass transfer that powers the low-mass as well as the massive X-ray binaries. Detailed numerical computations of the initial phase of Roche-lobe overflow were performed in order to determine the precise time development of the mass transfer from normal stars with masses ranging from 1.5 M(sun) up to 20 M(sun) to compact companions with masses of 1 and 1.5 M(sun). The binary code includes a simplified hydrodynamical treatment of Roche-lobe overflow. For massive primaries this hydrodynamical treatment appears to result in much longer X-ray lifetimes than obtained in previous investigations. The calculations also include effects of slow, non-synchronous rotation of the contact star and loss of mass and angular momentum from the binary system. For Her X-1 and Cen X-3 X-ray lifetimes of the order of 10 5 and 10 4 yrs are predicted, respectively

  9. Mécanique des sols et des roches

    CERN Document Server

    Vullier, Laurent; Zhao, Jian

    2016-01-01

    La mécanique des sols et la mécanique des roches sont des disciplines généralement traitées séparément dans la littérature. Pour la première fois, un traité réunit ces deux spécialités, en intégrant également les connaissances en lien avec les écoulements souterrains et les transferts thermiques. A la fois théorique et pratique, cet ouvrage propose tout d'abord une description détaillée de la nature et de la composition des sols et des roches, puis s'attache à la modélisation de problèmes aux conditions limites et présente les essais permettant de caractériser les sols et les roches, tant d'un point de vue mécanique qu'hydraulique et thermique. La problématique des sols non saturés et des écoulements multiphasiques est également abordée. Une attention particulière est portée aux lois de comportement mécanique et à la détermination de leurs paramètres par des essais in situ et en laboratoire, et l'ouvrage offre également une présentation détaillée des systèmes de classi...

  10. Chlamydia trachomatis infections in Greece: first prevalence study using nucleic acid amplification tests.

    Science.gov (United States)

    Levidiotou, S; Vrioni, G; Papadogeorgaki, H; Avdeliodi, K; Kada, H; Kaparos, G; Kouskouni, E; Fragouli, E; Legakis, N J

    2005-03-01

    The present retrospective study was initiated to determine the prevalence of Chlamydia trachomatis and to assess the risk factors for infection in adult women and men presenting to general practitioners, gynecologists, dermatologists, and family-planning centers in Greece. The study was carried out in four different Greek hospital centers using highly sensitive nucleic acid amplification techniques. Altogether, 16,834 women and 1,035 men were enrolled from October 1998 to April 2004. Two types of specimens were collected from each patient: cervical swabs from women, urethral swabs from men, and first-catch urine from women and men. All specimens were examined with the Cobas Amplicor C. trachomatis polymerase chain reaction assay (Roche Molecular Systems, Branchburg, NJ, USA) or the LC x C. trachomatis ligase chain reaction assay (Abbott Laboratories, Abbott Park, IL, USA). Demographic and behavioral data were collected by clinicians using a standardized questionnaire. A total of 704 (3.9%) patients were infected with C. trachomatis. The prevalence among female patients was 3.5% and that among male patients 11.2%. Among infected patients, 88% were under 30 years of age, 71% reported more than one sexual partner, and 91% reported a new sexual partner within the last year. In conclusion, the prevalence of C. trachomatis infection in Greece is low. Young age and new and multiple sexual partners within the last year were factors consistently associated with an increased risk of chlamydial infection.

  11. Submaximal Riemann-Roch expected curves and symplectic packing.

    Directory of Open Access Journals (Sweden)

    Wioletta Syzdek

    2007-06-01

    Full Text Available We study Riemann-Roch expected curves on $mathbb{P}^1 imes mathbb{P}^1$ in the context of the Nagata-Biran conjecture. This conjecture predicts that for sufficiently large number of points multiple points Seshadri constants of an ample line bundle on algebraic surface are maximal. Biran gives an effective lower bound $N_0$. We construct examples verifying to the effect that the assertions of the Nagata-Biran conjecture can not hold for small number of points. We discuss cases where our construction fails. We observe also that there exists a strong relation between Riemann-Roch expected curves on $mathbb{P}^1 imes mathbb{P}^1$ and the symplectic packing problem. Biran relates the packing problem to the existence of solutions of certain Diophantine equations. We construct such solutions for any ample line bundle on $mathbb{P}^1 imes mathbb{P}^1$ and a relatively smallnumber of points. The solutions geometrically correspond to Riemann-Roch expected curves. Finally we discuss in how far the Biran number $N_0$ is optimal in the case of mathbb{P}^1 imes mathbb{P}^1. In fact we conjecture that it can be replaced by a lower number and we provide evidence justifying this conjecture.

  12. Validation of a Human Papillomavirus (HPV) DNA Cervical Screening Test That Provides Expanded HPV Typing.

    Science.gov (United States)

    Demarco, Maria; Carter-Pokras, Olivia; Hyun, Noorie; Castle, Philip E; He, Xin; Dallal, Cher M; Chen, Jie; Gage, Julia C; Befano, Brian; Fetterman, Barbara; Lorey, Thomas; Poitras, Nancy; Raine-Bennett, Tina R; Wentzensen, Nicolas; Schiffman, Mark

    2018-05-01

    As cervical cancer screening shifts from cytology to human papillomavirus (HPV) testing, a major question is the clinical value of identifying individual HPV types. We aimed to validate Onclarity (Becton Dickinson Diagnostics, Sparks, MD), a nine-channel HPV test recently approved by the FDA, by assessing (i) the association of Onclarity types/channels with precancer/cancer; (ii) HPV type/channel agreement between the results of Onclarity and cobas (Roche Molecular Systems, Pleasanton, CA), another FDA-approved test; and (iii) Onclarity typing for all types/channels compared to typing results from a research assay (linear array [LA]; Roche). We compared Onclarity to histopathology, cobas, and LA. We tested a stratified random sample ( n = 9,701) of discarded routine clinical specimens that had tested positive by Hybrid Capture 2 (HC2; Qiagen, Germantown, MD). A subset had already been tested by cobas and LA ( n = 1,965). Cervical histopathology was ascertained from electronic health records. Hierarchical Onclarity channels showed a significant linear association with histological severity. Onclarity and cobas had excellent agreement on partial typing of HPV16, HPV18, and the other 12 types as a pool (sample-weighted kappa value of 0.83); cobas was slightly more sensitive for HPV18 and slightly less sensitive for the pooled high-risk types. Typing by Onclarity showed excellent agreement with types and groups of types identified by LA (kappa values from 0.80 for HPV39/68/35 to 0.97 for HPV16). Onclarity typing results corresponded well to histopathology and to an already validated HPV DNA test and could provide additional clinical typing if such discrimination is determined to be clinically desirable. This is a work of the U.S. Government and is not subject to copyright protection in the United States. Foreign copyrights may apply.

  13. Zika virus RNA polymerase chain reaction on the utility channel of a commercial nucleic acid testing system.

    Science.gov (United States)

    Boujnan, Mohamed; Duits, Ashley J; Koppelman, Marco H G M

    2018-03-01

    Several countries have implemented safety strategies to reduce the risk of Zika virus (ZIKV) transmission through blood transfusion. These strategies have included nucleic acid amplification testing (NAT) of blood donations. In this study, a new real-time polymerase chain reaction (PCR) assay including internal control for the detection of ZIKV on the cobas omni Utility Channel (UC) on the cobas 6800 system is presented. PCR conditions and primer/probe concentrations were optimized on the LightCycler 480 instrument. Optimized conditions were transferred to the cobas omni UC on the cobas 6800 system. Subsequently, the limit of detection (LOD) in plasma and urine, genotype inclusivity, specificity, cross-reactivity, and clinical sensitivity were determined. The 95% LOD of the ZIKV PCR assay on the cobas 6800 system was 23.0 IU/mL (95% confidence interval [CI], 16.5-37.5) in plasma and 24.5 IU/mL (95% CI, 13.4-92.9) in urine. The assay detected African and Asian lineages of ZIKV. The specificity was 100%. The clinical concordance between the newly developed ZIKV PCR assay and the investigational Roche cobas Zika NAT test was 83% (24/29). We developed a sensitive ZIKV PCR assay on the cobas omni UC on the cobas 6800 system. The assay can be used for large-scale screening of blood donations for ZIKV or for testing of blood donors returning from areas with ZIKV to avoid temporal deferral. This study also demonstrates that the cobas omni UC on the cobas 6800 system can be used for in-house-developed PCR assays. © 2018 AABB.

  14. LUNAR ACCRETION FROM A ROCHE-INTERIOR FLUID DISK

    Energy Technology Data Exchange (ETDEWEB)

    Salmon, Julien; Canup, Robin M., E-mail: julien@boulder.swri.edu, E-mail: robin@boulder.swri.edu [Department of Space Studies, Southwest Research Institute, 1050 Walnut Street, Suite 300, Boulder, CO 80302 (United States)

    2012-11-20

    We use a hybrid numerical approach to simulate the formation of the Moon from an impact-generated disk, consisting of a fluid model for the disk inside the Roche limit and an N-body code to describe accretion outside the Roche limit. As the inner disk spreads due to a thermally regulated viscosity, material is delivered across the Roche limit and accretes into moonlets that are added to the N-body simulation. Contrary to an accretion timescale of a few months obtained with prior pure N-body codes, here the final stage of the Moon's growth is controlled by the slow spreading of the inner disk, resulting in a total lunar accretion timescale of {approx}10{sup 2} years. It has been proposed that the inner disk may compositionally equilibrate with the Earth through diffusive mixing, which offers a potential explanation for the identical oxygen isotope compositions of the Earth and Moon. However, the mass fraction of the final Moon that is derived from the inner disk is limited by resonant torques between the disk and exterior growing moons. For initial disks containing <2.5 lunar masses (M{sub Last-Quarter-Moon }), we find that a final Moon with mass > 0.8 M{sub Last-Quarter-Moon} contains {<=}60% material derived from the inner disk, with this material preferentially delivered to the Moon at the end of its accretion.

  15. Cross-reactivity profiles of hybrid capture II, cobas, and APTIMA human papillomavirus assays

    DEFF Research Database (Denmark)

    Preisler, Sarah Nørgaard; Rebolj, Matejka; Ejegod, Ditte Møller

    2016-01-01

    evaluated to what extent these can be explained by cross-reactivity, i.e. positive test results without evidence of high-risk HPV genotypes. The patterns of cross-reactivity have been thoroughly studied for hybrid capture II (HC2) but not yet for newer HPV assays although the manufacturers claimed...... no or limited frequency of cross-reactivity. In this independent study we evaluated the frequency of cross-reactivity for HC2, cobas, and APTIMA assays. Methods Consecutive routine cervical screening samples from 5022 Danish women, including 2859 from women attending primary screening, were tested...... with normal cytology and positive high-risk HPV test results were invited for repeated testing in 18 months. Results Cross-reactivity to low-risk genotypes was detected in 109 (2.2 %) out of 5022 samples on HC2, 62 (1.2 %) on cobas, and 35 (0.7 %) on APTIMA with only 10 of the samples cross-reacting on all 3...

  16. Evaluation of the Aptima HBV Quant assay vs. the COBAS TaqMan HBV test using the high pure system for the quantitation of HBV DNA in plasma and serum samples.

    Science.gov (United States)

    Schalasta, Gunnar; Börner, Anna; Speicher, Andrea; Enders, Martin

    2018-03-28

    Proper management of patients with chronic hepatitis B virus (HBV) infection requires monitoring of plasma or serum HBV DNA levels using a highly sensitive nucleic acid amplification test. Because commercially available assays differ in performance, we compared herein the performance of the Hologic Aptima HBV Quant assay (Aptima) to that of the Roche Cobas TaqMan HBV test for use with the high pure system (HPS/CTM). Assay performance was assessed using HBV reference panels as well as plasma and serum samples from chronically HBV-infected patients. Method correlation, analytical sensitivity, precision/reproducibility, linearity, bias and influence of genotype were evaluated. Data analysis was performed using linear regression, Deming correlation analysis and Bland-Altman analysis. Agreement between the assays for the two reference panels was good, with a difference in assay values vs. target 0.98). The two assays had similar bias and precision across the different genotypes tested at low viral loads (25-1000 IU/mL). Aptima has a performance comparable with that of HPS/CTM, making it suitable for use for HBV infection monitoring. Aptima runs on a fully automated platform (the Panther system) and therefore offers a significantly improved workflow compared with HPS/CTM.

  17. Comparison of the Abbott RealTime CT new formulation assay with two other commercial assays for detection of wild-type and new variant strains of Chlamydia trachomatis

    DEFF Research Database (Denmark)

    Møller, Jens Kjølseth; Pedersen, Lisbeth Nørum; Persson, Kenneth

    2010-01-01

    In an analytical methods comparison study on clinical samples, the Abbott RealTime CT new formulation assay (m2000 real-time PCR) consisting of a duplex PCR targeting different parts of the cryptic plasmid in Chlamydia trachomatis was compared with version 2 of the Roche COBAS(R) TaqMan(R) CT ass...

  18. Prevalence of Chlamydia infection among women visiting a gynaecology outpatient department: evaluation of an in-house PCR assay for detection of Chlamydia trachomatis

    Directory of Open Access Journals (Sweden)

    Patel Achchhe L

    2010-09-01

    Full Text Available Abstract Background Screening women for Chlamydia trachomatis infection in developing countries is highly desirable because of asymptomatic infection. The existing diagnostic methods in developing countries are not effective and their sensitivity fall below 45.0% which leads to further spread of infection. There is an urgent need for improved and cost effective diagnostic tests that will reduce the burden of sexually transmitted infections in the developing world. Methods Prevalence of C. trachomatis infection among women visiting gynaecology department of Hindu Rao hospital in Delhi, India was determined using Roche Amplicor Multi Well Plate kit (MWP as well as using in-house PCR assay. We used 593 endocervical swabs for clinical evaluation of the in-house developed assay against Direct Fluorescence Assay (DFA; Group I n = 274 and Roche Amplicor MWP kit (Group II, n = 319 samples and determined the sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV of the in-house developed assay. Results We detected 23.0% positive cases and there was a higher representation of women aged 18-33 in this group. An in-house PCR assay was developed and evaluated by targeting unique sequence within the gyrA gene of C. trachomatis. Specificity of the reaction was confirmed by using genomic DNA of human and other STI related microorganisms as template. Assay is highly sensitive and can detect as low as 10 fg of C. trachomatis DNA. The resolved sensitivity of in-house PCR was 94.5% compared with 88.0% of DFA assay. The high specificity (98.4% and sensitivity (97.1% of the in-house assay against Roche kit and availability of test results within 3 hours allowed for immediate treatment and reduced the risk of potential onward transmission. Conclusions The in-house PCR method is cost effective (~ 20.0% of Roche assay and hence could be a better alternative for routine diagnosis of genital infection by C. trachomatis to facilitate

  19. The cobas® 6800/8800 System: a new era of automation in molecular diagnostics.

    Science.gov (United States)

    Cobb, Bryan; Simon, Christian O; Stramer, Susan L; Body, Barbara; Mitchell, P Shawn; Reisch, Natasa; Stevens, Wendy; Carmona, Sergio; Katz, Louis; Will, Stephen; Liesenfeld, Oliver

    2017-02-01

    Molecular diagnostics is a key component of laboratory medicine. Here, the authors review key triggers of ever-increasing automation in nucleic acid amplification testing (NAAT) with a focus on specific automated Polymerase Chain Reaction (PCR) testing and platforms such as the recently launched cobas® 6800 and cobas® 8800 Systems. The benefits of such automation for different stakeholders including patients, clinicians, laboratory personnel, hospital administrators, payers, and manufacturers are described. Areas Covered: The authors describe how molecular diagnostics has achieved total laboratory automation over time, rivaling clinical chemistry to significantly improve testing efficiency. Finally, the authors discuss how advances in automation decrease the development time for new tests enabling clinicians to more readily provide test results. Expert Commentary: The advancements described enable complete diagnostic solutions whereby specific test results can be combined with relevant patient data sets to allow healthcare providers to deliver comprehensive clinical recommendations in multiple fields ranging from infectious disease to outbreak management and blood safety solutions.

  20. Evaluating new HbA1c methods for adoption by the IFCC and NGSP reference networks using international quality targets.

    Science.gov (United States)

    Lenters-Westra, Erna; English, Emma

    2017-08-28

    As a reference laboratory for HbA1c, it is essential to have accurate and precise HbA1c methods covering a range of measurement principles. We report an evaluation of the Abbott Enzymatic (Architect c4000), Roche Gen.3 HbA1c (Cobas c513) and Tosoh G11 using different quality targets. The effect of hemoglobin variants, other potential interferences and the performance in comparison to both the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the National Glycohemoglobin Standardization Program (NGSP) reference systems was assessed using certified evaluation protocols. Each of the evaluated HbA1c methods had CVs HbA1c. Partly based on the result of this study, the Abbott Enzymatic method on the Architect c4000 and the Roche Gen.3 HbA1c on the Cobas c513 are now official, certified IFCC and NGSP SRMPs in the IFCC and NGSP networks. Sigma metrics quality criteria presented in a graph distinguish between good and excellent performance.

  1. FROM HOT JUPITERS TO SUPER-EARTHS VIA ROCHE LOBE OVERFLOW

    Energy Technology Data Exchange (ETDEWEB)

    Valsecchi, Francesca; Rasio, Frederic A.; Steffen, Jason H. [Center for Interdisciplinary Exploration and Research in Astrophysics (CIERA) and Department of Physics and Astronomy, Northwestern University, 2145 Sheridan Road, Evanston, IL 60208 (United States)

    2014-09-20

    Through tidal dissipation in a slowly spinning host star, the orbits of many hot Jupiters may decay down to the Roche limit. We expect that the ensuing mass transfer will be stable in most cases. Using detailed numerical calculations, we find that this evolution is quite rapid, potentially leading to the complete removal of the gaseous envelope in a few gigayears, and leaving behind an exposed rocky core (a {sup h}ot super-Earth{sup )}. Final orbital periods are quite sensitive to the details of the planet's mass-radius relation and to the effects of irradiation and photo-evaporation, but could be as short as a few hours or as long as several days. Our scenario predicts the existence of planets with intermediate masses ({sup h}ot Neptunes{sup )} that should be found precisely at their Roche limit and in the process of losing mass through Roche lobe overflow. The observed excess of small single-planet candidate systems observed by Kepler may also be the result of this process. If so, the properties of their host stars should track those of the hot Jupiters. Moreover, the number of systems that produced hot Jupiters could be two to three times larger than one would infer from contemporary observations.

  2. Small-scale hydro-electric scheme in Roches, Switzerland; Projet de concession. Petite centrale hydroelectrique de Roches

    Energy Technology Data Exchange (ETDEWEB)

    Hausmann, M.

    2006-07-01

    The small hydropower plant (SHPP) project 'PCH Roches' is planned to be built in Roches, a small village located in the Jura region of the canton of Bern. The goal of this undertaking is to reactivate a site with hydro potential of the river Birs on a section that was already well exploited by some ancient SHPP (since 1953 or probably even earlier). Several modifications were performed on this plant over the years; not all contributed positively on its production figures. Following a transfer of the water rights in 1987, claims became loud against the owner to perform maintenance on the river banks and to modify the weir such that a free passage for the fishes will be granted. Those issues contributed to inflate a conflict which ended in the repeal of the water rights and a total plant shut down in 2001. The new project plans to reuse the existing pen stock and to carry out some refurbishing activities to grant security and better performance. The weir and the intake structure are also redesigned such that the water storage can be somewhat raised for normal operation; a weir gate will however allow to better discharge the river in flood situations. A new turbine house will be erected at the current location where the tail water pen stock rejoins the river. Hence, the existing old turbine house will be obsolete and the upper and lower pen stock sections are to be linked with each other. Limited by the existing pen stock size, the new plant is expected to produce some 50 kW power and 362,000 kWh/year. This represents an increase in energy generation of around 200% compared with the ancient SHPP. Gross head is 5.38 m, net head 4.12 m with a turbine flow of at least 1.6 m{sup 3}/s. The expected energy sales price applicable to this project reaches about 0.17 CHF/kWh as per the current tariffs set by the grid owner. This project calls for the building of a state-of-the-art SHPP. It will avoid the total dismantling of the existing works to take place and allow

  3. Detection of BRAF V600 mutations in melanoma: evaluation of concordance between the Cobas® 4800 BRAF V600 mutation test and the methods used in French National Cancer Institute (INCa) platforms in a real-life setting.

    Science.gov (United States)

    Mourah, Samia; Denis, Marc G; Narducci, Fabienne Escande; Solassol, Jérôme; Merlin, Jean-Louis; Sabourin, Jean-Christophe; Scoazec, Jean-Yves; Ouafik, L'Houcine; Emile, Jean-François; Heller, Remy; Souvignet, Claude; Bergougnoux, Loïc; Merlio, Jean-Philippe

    2015-01-01

    Vemurafenib is approved for the treatment of metastatic melanoma in patients with BRAF V600 mutation. In pivotal clinical trials, BRAF testing has always been done with the approved cobas 4800 BRAF test. In routine practice, several methods are available and are used according to the laboratories usual procedures. A national, multicenter, non-interventional study was conducted with prospective and consecutive collection of tumor samples. A parallel evaluation was performed in routine practice between the cobas 4800 BRAF V600 mutation test and home brew methods (HBMs) of 12 national laboratories, labelled and funded by the French National Cancer Institute (INCa). For 420 melanoma samples tested, the cobas method versus HBM showed a high concordance (93.3%; kappa = 0.86) in BRAF V600 genotyping with similar mutation rates (34.0% versus 35.7%, respectively). Overall, 97.4% and 98.6% of samples gave valid results using the cobas and HBM, respectively. Of the 185 samples strictly fulfilling the cobas guidelines, the concordance rate was even higher (95.7%; kappa = 0.91; 95%CI [0.85; 0.97]). Out of the 420 samples tested, 28 (6.7%) showed discordance between HBM and cobas. This prospective study shows a high concordance rate between the cobas 4800 BRAF V600 test and home brew methods in the routine detection of BRAF V600E mutations.

  4. Detection of BRAF V600 Mutations in Melanoma: Evaluation of Concordance between the Cobas® 4800 BRAF V600 Mutation Test and the Methods Used in French National Cancer Institute (INCa) Platforms in a Real-Life Setting

    Science.gov (United States)

    Mourah, Samia; Denis, Marc G.; Narducci, Fabienne Escande; Solassol, Jérôme; Merlin, Jean-Louis; Sabourin, Jean-Christophe; Scoazec, Jean-Yves; Ouafik, L’Houcine; Emile, Jean-François; Heller, Remy; Souvignet, Claude; Bergougnoux, Loïc; Merlio, Jean-Philippe

    2015-01-01

    Vemurafenib is approved for the treatment of metastatic melanoma in patients with BRAF V600 mutation. In pivotal clinical trials, BRAF testing has always been done with the approved cobas 4800 BRAF test. In routine practice, several methods are available and are used according to the laboratories usual procedures. A national, multicenter, non-interventional study was conducted with prospective and consecutive collection of tumor samples. A parallel evaluation was performed in routine practice between the cobas 4800 BRAF V600 mutation test and home brew methods (HBMs) of 12 national laboratories, labelled and funded by the French National Cancer Institute (INCa). For 420 melanoma samples tested, the cobas method versus HBM showed a high concordance (93.3%; kappa = 0.86) in BRAF V600 genotyping with similar mutation rates (34.0% versus 35.7%, respectively). Overall, 97.4% and 98.6% of samples gave valid results using the cobas and HBM, respectively. Of the 185 samples strictly fulfilling the cobas guidelines, the concordance rate was even higher (95.7%; kappa = 0.91; 95%CI [0.85; 0.97]). Out of the 420 samples tested, 28 (6.7%) showed discordance between HBM and cobas. This prospective study shows a high concordance rate between the cobas 4800 BRAF V600 test and home brew methods in the routine detection of BRAF V600E mutations. PMID:25789737

  5. Detection of BRAF V600 mutations in melanoma: evaluation of concordance between the Cobas® 4800 BRAF V600 mutation test and the methods used in French National Cancer Institute (INCa platforms in a real-life setting.

    Directory of Open Access Journals (Sweden)

    Samia Mourah

    Full Text Available Vemurafenib is approved for the treatment of metastatic melanoma in patients with BRAF V600 mutation. In pivotal clinical trials, BRAF testing has always been done with the approved cobas 4800 BRAF test. In routine practice, several methods are available and are used according to the laboratories usual procedures. A national, multicenter, non-interventional study was conducted with prospective and consecutive collection of tumor samples. A parallel evaluation was performed in routine practice between the cobas 4800 BRAF V600 mutation test and home brew methods (HBMs of 12 national laboratories, labelled and funded by the French National Cancer Institute (INCa. For 420 melanoma samples tested, the cobas method versus HBM showed a high concordance (93.3%; kappa = 0.86 in BRAF V600 genotyping with similar mutation rates (34.0% versus 35.7%, respectively. Overall, 97.4% and 98.6% of samples gave valid results using the cobas and HBM, respectively. Of the 185 samples strictly fulfilling the cobas guidelines, the concordance rate was even higher (95.7%; kappa = 0.91; 95%CI [0.85; 0.97]. Out of the 420 samples tested, 28 (6.7% showed discordance between HBM and cobas. This prospective study shows a high concordance rate between the cobas 4800 BRAF V600 test and home brew methods in the routine detection of BRAF V600E mutations.

  6. A Simple Phosphate-Buffered-Saline-Based Extraction Method Improves Specificity of HIV Viral Load Monitoring Using Dried Blood Spots.

    Science.gov (United States)

    Makadzange, A Tariro; Boyd, F Kathryn; Chimukangara, Benjamin; Masimirembwa, Collen; Katzenstein, David; Ndhlovu, Chiratidzo E

    2017-07-01

    Although Roche COBAS Ampliprep/COBAS TaqMan (CAP/CTM) systems are widely used in sub-Saharan Africa for early infant diagnosis of HIV from dried blood spots (DBS), viral load monitoring with this system is not practical due to nonspecific extraction of both cell-free and cell-associated viral nucleic acids. A simplified DBS extraction technique for cell-free virus elution using phosphate-buffered saline (PBS) may provide an alternative analyte for lower-cost quantitative HIV virus load (VL) testing to monitor antiretroviral therapy (ART). We evaluated the CAP/CTM v2.0 assay in 272 paired plasma and DBS specimens using the cell-free virus elution method and determined the level of agreement, sensitivity, and specificity at thresholds of target not detected (TND), target below the limit of quantification (BLQ) (1,000 copies/ml, the sensitivities, specificities, positive predictive values (PPV), and negative predictive values (NPV) were 92.7%, 100%, 100%, and 94.3%, respectively. PBS elution of DBS offers a sensitive and specific method for monitoring plasma viremia among adults and children on ART at the WHO-recommended threshold of >1,000 copies/ml on the Roche CAP/CTM system. Copyright © 2017 Makadzange et al.

  7. Performance of the Xpert HPV assay in women attending for cervical screening

    Directory of Open Access Journals (Sweden)

    Jack Cuzick

    2015-12-01

    Full Text Available Objectives: This study evaluated the Xpert HPV Assay in women attending screening in general practice by comparing Xpert with two established HPV tests, cytology and histology. Methods: A prospective study in women aged 20–60 years attending screening in Bristol, Edinburgh and London using residual Preservcyt cytology samples. Sample order was randomised between Roche cobas4800 and Cepheid Xpert assays with Qiagen hc2 third. Results: 3408 cases were included in the primary analysis. Positivity for Xpert was 19.6%, cobas 19.2% and hc2 19.9% with high concordance (kappa=86.8% vs cobas, 81.55 vs hc2. Xpert, cobas and hc2 showed similar sensitivity (98.7%, 97.5%, 98.7% for CIN2+. All pairwise comparisons had high concordance (Kappa ≥0.78 with any abnormal cytology. Xpert and hc2 were positive for all cases of ≥moderate dyskaryosis (N=63, cobas was negative in two. Histology was available for 172 participants. 79 reported CIN2+, 47 CIN3+. All CIN3+ was positive on Xpert and hc2 and one case negative for cobas. One case of CIN2 was negative for all assays. Conclusions: The performance of Xpert HPV Assay in a general screening population is comparable to established HPV tests. It offers simplicity of testing, flexibility with non-batching of individual samples and rapid turnaround time. Keywords: Human papillomavirus, Xpert, Cervical screening, HPV testing

  8. An Evaluation of the Cobas4800 HPV Test on Cervico-Vaginal Specimens in Liquid versus Solid Transport Media.

    Directory of Open Access Journals (Sweden)

    Hongxue Luo

    Full Text Available Determine the ability of the Cobas 4800 assay to detect high-risk human papillomavirus (HrHPV and high-grade cervical lesions when using cervico-vaginal samples applied to liquid medium and solid media cards compared to a direct cervical sample.Two cervico-vaginal specimens (pseudo self-collected were obtained from 319 women. One was applied to an iFTA Card (FTA then the brush placed in liquid-based medium (LSELF; the other was applied to a new solid media: POI card (POI. The clinical performance of Cobas4800 assay using the three aforementioned specimens was compared to direct collected endocervical specimens in liquid media (LDOC.The overall agreements of HrHPV detection were 84.2% (LSELF vs. LDOC, 81.0% (FTA vs. LDOC, and 82.3% (POI vs. LDOC. LSELF, FTA and POI identified 98.0%, 79.6%, and 97.5% positive cases of LDOC. Sensitivity to identify CIN2+ were 98.4% (LSELF, 73.8% (FTA, 95.1% (POI, and 93.4% (LDOC respectively. FTA had 78.1% and 90.4% agreement with the LSELF samples for all HrHPV and HPV16/18 detection respectively, while POI had 91.6% for both.Cobas4800 HPV test combined with cervico-vaginal specimens applied to both liquid media and POI solid card are accurate to detect HrHPV infection and high-grade cervical lesions as compared with direct endocervical samples in liquid media.

  9. An Evaluation of the Cobas4800 HPV Test on Cervico-Vaginal Specimens in Liquid versus Solid Transport Media.

    Science.gov (United States)

    Luo, Hongxue; Du, Hui; Maurer, Kathryn; Belinson, Jerome L; Wang, Guixiang; Liu, Zhihong; Zhang, Lijie; Zhou, Yanqiu; Wang, Chun; Tang, Jinlong; Qu, Xinfeng; Wu, Ruifang

    2016-01-01

    Determine the ability of the Cobas 4800 assay to detect high-risk human papillomavirus (HrHPV) and high-grade cervical lesions when using cervico-vaginal samples applied to liquid medium and solid media cards compared to a direct cervical sample. Two cervico-vaginal specimens (pseudo self-collected) were obtained from 319 women. One was applied to an iFTA Card (FTA) then the brush placed in liquid-based medium (LSELF); the other was applied to a new solid media: POI card (POI). The clinical performance of Cobas4800 assay using the three aforementioned specimens was compared to direct collected endocervical specimens in liquid media (LDOC). The overall agreements of HrHPV detection were 84.2% (LSELF vs. LDOC), 81.0% (FTA vs. LDOC), and 82.3% (POI vs. LDOC). LSELF, FTA and POI identified 98.0%, 79.6%, and 97.5% positive cases of LDOC. Sensitivity to identify CIN2+ were 98.4% (LSELF), 73.8% (FTA), 95.1% (POI), and 93.4% (LDOC) respectively. FTA had 78.1% and 90.4% agreement with the LSELF samples for all HrHPV and HPV16/18 detection respectively, while POI had 91.6% for both. Cobas4800 HPV test combined with cervico-vaginal specimens applied to both liquid media and POI solid card are accurate to detect HrHPV infection and high-grade cervical lesions as compared with direct endocervical samples in liquid media.

  10. Verrerie de Passavant-la-Rochère/faïencerie de Salins

    OpenAIRE

    Barbe, Noël

    2007-01-01

    Le travail du verre est présent dès le Moyen Age à Passavant-la-Rochère. A Salins, la production céramique date du début du xviiie siècle. Sur chacun de ces sites subsiste une unité de production représentant par ailleurs la dernière activité de ce type dans la région administrative constituée par la Franche-Comté. La verrerie de Passavant-la-Rochère est une entreprise familiale employant 250 ouvriers. La faïencerie de Salins est aujourd'hui intégrée au groupe Sarreguemines-Digoin dont elle c...

  11. Verwerking en rapportage van meetgegevens verkregen met een Cobas-Bio centrifugaal-analysator m.b.v. de RIVM-computer

    NARCIS (Netherlands)

    Steentjes; G.M.; Koedam; J.C.

    1985-01-01

    Voor de verwerking van grote hoeveelheden meetgegevens is o.a. voor de Cobas-Bio centrifugaal analysator m.b.v. de RIVM computer een systeem ontwikkeld dat zowel monster (patient) identificatie, als rapportage van alle analyseresultaten verzorgt, zodat door het automatisch uitvoeren van een

  12. Spiral shocks on a Roche lobe overflow in a semi-detached binary system

    International Nuclear Information System (INIS)

    Sawada, K.; Matsuda, T.; Hachisu, I.

    1986-01-01

    Two-dimensional hydrodynamic calculations of a Roche lobe overflow in a semi-detached binary system with a mass ratio of unity are carried out. The region of the computation covers both a mass-losing star filling its critical Roche lobe and a mass-accreting compact star. Gas ejected from the mass-losing star with specified energy flows through the L1 point to form an elephant trunk and an accretion ring. It is found that spiral-shaped shocks are formed on the accretion ring. It is suggested that the gas in the accretion ring loses angular momentum at the shocks and spirals in towards the compact star even without viscosity. (author)

  13. Comparison of two immunoassay systems for hCGβ and PAPP-A in prenatal screening for trisomy 21, 18, and 13 in the first trimester

    Directory of Open Access Journals (Sweden)

    Anna Elise Engell

    2017-12-01

    Full Text Available Objectives: The biochemical serum markers free β-human chorionic gonadotropin (hCGβ and pregnancy associated plasma protein A (PAPP-A, used in screening for trisomy 21 (T21, trisomy 18 (T18, and trisomy 13 (T13 during the first trimester, can be measured on different laboratory instruments e.g. Kryptor (Brahms and Cobas (Roche. We compared the performance of these two analytical instruments when used for first trimester combined testing. Design and methods: Serum samples from 944 singleton pregnant women attending for first trimester combined testing were routinely assayed for hCGβ and PAPP-A on Kryptor, and re-analyzed on Cobas. In addition, serum samples from 70 pregnant women carrying a fetus affected by T21, T18 or T13, were re-assayed on Cobas. Results: For the screening population, the hCGβ and PAPP-A results in multiples of the median (MoM from Kryptor and Cobas were significantly lower on Cobas when compared to Kryptor. The number of pregnant women with a risk above 1:300 for T21 was 48 for both Cobas and Kryptor, although a few patients only had a high risk with one of the methods. Overall, the screen positive rate was 5.1% for both instruments. In the trisomy groups the calculated risks for T21, T18, and T13 agreed well between Cobas and Kryptor. Conclusions: The screen positive rate for T21 (5.1% did not differ between the two analytical platforms in our screening population, although PAPP-A measurements form Cobas were significantly lower than those from Kryptor. The calculated risks for the pregnancies affected by trisomies using hCGβ MoM and PAPP-A MoM from Kryptor agreed well with those from Cobas. Keywords: Aneuploidy, Combined first trimester screening, First trimester risk assessment, Free β-human chorionic gonadotropin (hCGβ, Pregnancy associated plasma protein-A (PAPP-A, Trisomy screening

  14. Comparison between Roche and Xpert in HIV-1 RNA quantitation: A high concordance between the two techniques except for a CRF02_AG subtype variant with high viral load titters detected by Roche but undetected by Xpert.

    Science.gov (United States)

    Avidor, Boaz; Matus, Natalia; Girshengorn, Shirley; Achsanov, Svetlana; Gielman, Simona; Zeldis, Irene; Schweitzer, Inbal; Adler, Amos; Turner, Dan

    2017-08-01

    HIV-1 viral load (VL) testing is important to predict viral progression and to monitor the response to antiretroviral therapy. New HIV-1 VL tests are continuously introduced to the market. Their performance is usually compared to Abbott and/or Roche HIV-1 VL assays, as reference. The Xpert HIV-1 VL test was recently introduced, but its performance compared to Roche has not been sufficiently studied. To compare the Xpert assay with Roche and to assess its use in the HIV clinical laboratory. A total of 383 plasma samples of HIV-1 infected patients previously tested by Roche, were retrospectively tested by Xpert to determine concordance between the two assays. Samples included a diversity of HIV-1 subtypes and a wide range of VLs. There was a high concordance between the two assays, except for a CRF02_AG subtype variant with high VL titters, that was detected by Roche but undetected by Xpert. The 5' long terminal repeat gene region of this virus, targeted by the Xpert assay, was amplified and sequenced. A 25 nucleotide insert was identified, but was unmatched to any known sequences of HIV-1. This particular insert, however could not explain the false-negativity by the Xpert assay. This study underlines the challenge to routine VL testing due to the high genetic diversity of HIV-1. Clinicians should, therefore be advised that a negative VL in cases where the clinical picture does not match the laboratory report, might in fact be, a false-negative result of the VL assay. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Ice cream and orbifold Riemann-Roch

    Science.gov (United States)

    Buckley, Anita; Reid, Miles; Zhou, Shengtian

    2013-06-01

    We give an orbifold Riemann-Roch formula in closed form for the Hilbert series of a quasismooth polarized n-fold (X,D), under the assumption that X is projectively Gorenstein with only isolated orbifold points. Our formula is a sum of parts each of which is integral and Gorenstein symmetric of the same canonical weight; the orbifold parts are called ice cream functions. This form of the Hilbert series is particularly useful for computer algebra, and we illustrate it on examples of {K3} surfaces and Calabi-Yau 3-folds. These results apply also with higher dimensional orbifold strata (see [1] and [2]), although the precise statements are considerably trickier. We expect to return to this in future publications.

  16. Ice cream and orbifold Riemann-Roch

    International Nuclear Information System (INIS)

    Buckley, Anita; Reid, Miles; Zhou Shengtian

    2013-01-01

    We give an orbifold Riemann-Roch formula in closed form for the Hilbert series of a quasismooth polarized n-fold (X,D), under the assumption that X is projectively Gorenstein with only isolated orbifold points. Our formula is a sum of parts each of which is integral and Gorenstein symmetric of the same canonical weight; the orbifold parts are called ice cream functions. This form of the Hilbert series is particularly useful for computer algebra, and we illustrate it on examples of K3 surfaces and Calabi-Yau 3-folds. These results apply also with higher dimensional orbifold strata (see [1] and [2]), although the precise statements are considerably trickier. We expect to return to this in future publications.

  17. TIDALLY DRIVEN ROCHE-LOBE OVERFLOW OF HOT JUPITERS WITH MESA

    Energy Technology Data Exchange (ETDEWEB)

    Valsecchi, Francesca; Rasio, Frederic A. [Center for Interdisciplinary Exploration and Research in Astrophysics (CIERA), and Northwestern University, Department of Physics and Astronomy, Evanston, IL 60208 (United States); Rappaport, Saul [Department of Physics, and Kavli Institute for Astrophysics and Space Research, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Marchant, Pablo [Argelander-Institut für Astronomie, Universität Bonn, Auf dem Hgel 71, D-53121 Bonn (Germany); Rogers, Leslie A., E-mail: francesca@u.northwestern.edu, E-mail: rasio@northwestern.edu, E-mail: sar@mit.edu, E-mail: pablo@astro.uni-bonn.de, E-mail: larogers@caltech.edu [Department of Astronomy and Department of Geophysics and Planetary Sciences, California Institute of Technology, Pasadena, CA 91125 (United States)

    2015-11-10

    Many exoplanets have now been detected in orbits with ultra-short periods very close to the Roche limit. Building upon our previous work, we study the possibility that mass loss through Roche lobe overflow (RLO) may affect the evolution of these planets, and could possibly transform a hot Jupiter into a lower-mass planet (hot Neptune or super-Earth). We focus here on systems in which the mass loss occurs slowly (“stable mass transfer” in the language of binary star evolution) and we compute their evolution in detail with the binary evolution code Modules for Experiments in Stellar Astrophysics. We include the effects of tides, RLO, irradiation, and photo-evaporation (PE) of the planet, as well as the stellar wind and magnetic braking. Our calculations all start with a hot Jupiter close to its Roche limit, in orbit around a Sun-like star. The initial orbital decay and onset of RLO are driven by tidal dissipation in the star. We confirm that such a system can indeed evolve to produce lower-mass planets in orbits of a few days. The RLO phase eventually ends and, depending on the details of the mass transfer and on the planetary core mass, the orbital period can remain around a few days for several Gyr. The remnant planets have rocky cores and some amount of envelope material, which is slowly removed via PE at a nearly constant orbital period; these have properties resembling many of the observed super-Earths and sub-Neptunes. For these remnant planets, we also predict an anti-correlation between mass and orbital period; very low-mass planets (M{sub pl} ≲ 5 M{sub ⊕}) in ultra-short periods (P{sub orb} < 1 day) cannot be produced through this type of evolution.

  18. Disainmööbel Roche Bobois, kokteil sarmist ja romantikast / Reet Krause

    Index Scriptorium Estoniae

    Krause, Reet, 1967-

    2004-01-01

    Luksuslikku kodumööblit tootvast prantsuse firmast. Firma disainerid itaallased Paola Navone ja Massimo Iosa Ghini, Vladimir Kagan, Hans Hopper ja prantslased Jean Claude Magirard ja Sylvain Joly. Philippe Roche ja disainer Hans Hopperi kommentaar

  19. El concepto de límite en el B-Mu de François Roche

    Directory of Open Access Journals (Sweden)

    Eugenio Pandolfini

    2012-12-01

    Full Text Available

    Resumen

    Algunos proyectos, como el Dusty relief/B‐mu (2002 de François Roche demuestran como edificios complejos, que toman distancia desde los modelos mecanicistas para referirse a nuevos paradigmas, se pueden interpretar y comprenderse  mejor gracias a un análisis perceptivo que acerca el proyecto de arquitectura a cuestiones como la relación psicológica del hombre con la arquitectura, el miedo al espacio, y las  patologías  vinculadas a la percepción y a las neurosis modernas.
    En este caso, aparte de las repercusiones que la fachada de  polvo podría tener en el ámbito de la ecología urbana, es interesante analizar algunos aspectos ligados a la dicotomía  entre forma externa y volúmenes internos para la que François Roche cita como referencia el raumplan de Adolf Loos, pero que presenta motivos para una reflexión vinculada a los aspectos  perceptivos.
    El artículo trata de analizar como François Roche proyecta sus edificios extremando la dicotomía entre interior/visual y  exterior/táctil, desarrollando así una nueva relación con el lugar. Roche diseña la fachada exterior del B‐mu autoimponiéndose  una limitación del sentido de la vista, a favor de una dimensión háptica del proyecto y lo hace envolviendo los ámbitos arquitectónicos más familiares de una interfaz abstracta y táctil.

    Palabras clave

    edificio, percepción, entorno, envolvente, límite

    Abstract

    Some projects such as Dusty relief/B‐mu (2002 by François  Roche demonstrate how complex buildings, which distance themselves from the mechanicist models in order to refer  themselves to new paradigms, can be better understood and interpreted thanks to a perceptive analysis.
    This analysis brings the architectural project closer to matters  such as man’s psychological relationship to Architecture, the fear of space

  20. Prévalence des dyslipidémies au laboratoire de biochimie du CHU ...

    African Journals Online (AJOL)

    Le cholestérol total, le cholestérol HDL, le cholestérol LDL ainsi que les triglycérides ont été dosés grâce à des méthodes enzymatiques sur un automate de Biochimie de type Cobas Integra 400 (Roche Diagnostics). Résultats: la prévalence des dyslipidémies dans notre population d'étude est de 39,30%. Les prévalences ...

  1. Homage to Jean Roche

    CERN Multimedia

    2010-01-01

    It was with deep sadness that we learnt that Jean Roche had died. Jean was one of those quietly efficient and conscientious pillars of our community who beaver away unobtrusively for decades and make such a contribution to building CERN. An expert in thermal engineering, he left his mark on many buildings on the Meyrin and Prévessin sites. At the time of the LEP project at the beginning of the 1980s he was in charge of defining the principles of the ventilation systems for the new accelerator. Through his design studies and the calls for tenders that he launched, he developed these high-performance state-of-the-art installations which not only made LEP’s successes possible but also served as benchmarks for the fundamental principles underpinning the design of the LHC ventilation system. Jean always liked to surround himself with young people and during the years of his stewardship the design office was a splendid training ground. Despite his responsibilities, Jean was always keen t...

  2. Diagnosis and follow-up of genital chlamydial infection by direct methods and by detection of serum IgG, IgA and secretory IgA

    Directory of Open Access Journals (Sweden)

    Fresse A

    2010-01-01

    Full Text Available Purpose: To determine the prevalence of Chlamydia trachomatis infection in a high-risk population by direct and indirect methods and to evaluate the diagnosis of secretory immunoglobulin A (sIgA. Patients and Methods: Urethral or endocervical specimens from 78 patients (48 females and 30 males were examined by cell culture, direct fluorescence assay, PCR Cobas Amplicor (Roche Molecular Diagnostics, and sIgA was detected by the recombinant lipopolysaccharide (LPS-enzyme-linked immunoassay (rELISA. Serum from each patient was also obtained and analysed for the presence of IgG and IgA antibody by in-house microimmunofluorescence (MIF and by the rELISA method (Medac, Hamburg, Germany. Results: The overall C. trachomatis prevalence determined by direct methods was 28%. The detection of sIgA antibodies was significantly higher in the group of patients with a positive direct detection (50% than in the group of negative direct detection (10.7%. The Chlamydia-specific IgA antibodies were detected by the rELISA in 40.9 and 53.6% of group I (positive direct detection and group II patients (negative direct detection, respectively. The species-specific IgA antibodies were detected by the MIF method in 18.2 and 16.1% of group I and II patients, respectively. Chlamydia genus-specific IgG antibodies were detected by the rELISA in 86.4 and 83.9% of group I and group II patients and, C. trachomatis specific IgG were present in 81.8 and 73.2% of group I and group II patients, respectively, as assessed by the MIF test. Conclusion: Combining the positive direct methods and/or positive sIgA antibody results from cervical or urethral specimens had an indication of current C. trachomatis infection.

  3. Chlamydia trachomatis infection and sexual behaviour among female students attending higher education in the Republic of Ireland.

    LENUS (Irish Health Repository)

    O'Connell, Emer

    2009-10-29

    BACKGROUND: There are no prevalence data on Chlamydia trachomatis relating to female students attending higher education available for the Republic of Ireland. This information is required to guide on the necessity for Chlamydia screening programmes in higher education settings. This research aimed to determine the prevalence of and predictive risk factors for Chlamydia trachomatis genital infection among female higher education students in Ireland. METHODS: All females presenting during one-day periods at Student Health Units in three higher education institutions in two cities in the Republic of Ireland were invited to participate. Participants completed a questionnaire on lifestyle and socio-demographic factors and provided a urine sample. Samples were tested for C. trachomatis DNA by a PCR based technique (Cobas Amplicor, Roche). To examine possible associations between a positive test and demographic and lifestyle risk factors, a univariate analysis was performed. All associations with a p value < 0.05 were included in a multivariate logistic regression analysis. RESULTS: Of the 460 sexually active participants 22 tested positive (prevalence 4.8%; 95% CI 3.0 to 7.1%). Variables associated with significantly increased risk were current suggestive symptoms, two or more one-night stands and three or more lifetime sexual partners. The students displayed high-risk sexual behaviour. CONCLUSION: The prevalence of C. trachomatis infection and the lack of awareness of the significance of suggestive symptoms among sexually experienced female students demonstrate the need for a programme to test asymptomatic or non-presenting higher education students. The risk factors identified by multivariate analysis may be useful in identifying those who are most likely to benefit from screening. Alcohol abuse, condom use, sexual behaviour (at home and abroad) and, knowledge of sexually transmitted infections (STIs) (including asymptomatic nature or relevant symptoms) were

  4. Chlamydia trachomatis infection and sexual behaviour among female students attending higher education in the Republic of Ireland

    Directory of Open Access Journals (Sweden)

    Vellinga Akke

    2009-10-01

    Full Text Available Abstract Background There are no prevalence data on Chlamydia trachomatis relating to female students attending higher education available for the Republic of Ireland. This information is required to guide on the necessity for Chlamydia screening programmes in higher education settings. This research aimed to determine the prevalence of and predictive risk factors for Chlamydia trachomatis genital infection among female higher education students in Ireland. Methods All females presenting during one-day periods at Student Health Units in three higher education institutions in two cities in the Republic of Ireland were invited to participate. Participants completed a questionnaire on lifestyle and socio-demographic factors and provided a urine sample. Samples were tested for C. trachomatis DNA by a PCR based technique (Cobas Amplicor, Roche. To examine possible associations between a positive test and demographic and lifestyle risk factors, a univariate analysis was performed. All associations with a p value Results Of the 460 sexually active participants 22 tested positive (prevalence 4.8%; 95% CI 3.0 to 7.1%. Variables associated with significantly increased risk were current suggestive symptoms, two or more one-night stands and three or more lifetime sexual partners. The students displayed high-risk sexual behaviour. Conclusion The prevalence of C. trachomatis infection and the lack of awareness of the significance of suggestive symptoms among sexually experienced female students demonstrate the need for a programme to test asymptomatic or non-presenting higher education students. The risk factors identified by multivariate analysis may be useful in identifying those who are most likely to benefit from screening. Alcohol abuse, condom use, sexual behaviour (at home and abroad and, knowledge of sexually transmitted infections (STIs (including asymptomatic nature or relevant symptoms were identified as target areas for health promotion strategies

  5. Small-scale hydro-electric scheme in Roches, Switzerland

    International Nuclear Information System (INIS)

    Hausmann, M.

    2006-01-01

    The small hydropower plant (SHPP) project 'PCH Roches' is planned to be built in Roches, a small village located in the Jura region of the canton of Bern. The goal of this undertaking is to reactivate a site with hydro potential of the river Birs on a section that was already well exploited by some ancient SHPP (since 1953 or probably even earlier). Several modifications were performed on this plant over the years; not all contributed positively on its production figures. Following a transfer of the water rights in 1987, claims became loud against the owner to perform maintenance on the river banks and to modify the weir such that a free passage for the fishes will be granted. Those issues contributed to inflate a conflict which ended in the repeal of the water rights and a total plant shut down in 2001. The new project plans to reuse the existing pen stock and to carry out some refurbishing activities to grant security and better performance. The weir and the intake structure are also redesigned such that the water storage can be somewhat raised for normal operation; a weir gate will however allow to better discharge the river in flood situations. A new turbine house will be erected at the current location where the tail water pen stock rejoins the river. Hence, the existing old turbine house will be obsolete and the upper and lower pen stock sections are to be linked with each other. Limited by the existing pen stock size, the new plant is expected to produce some 50 kW power and 362,000 kWh/year. This represents an increase in energy generation of around 200% compared with the ancient SHPP. Gross head is 5.38 m, net head 4.12 m with a turbine flow of at least 1.6 m 3 /s. The expected energy sales price applicable to this project reaches about 0.17 CHF/kWh as per the current tariffs set by the grid owner. This project calls for the building of a state-of-the-art SHPP. It will avoid the total dismantling of the existing works to take place and allow the small

  6. Interference by antiruthenium antibodies in the Roche thyroid-stimulating hormone assay

    NARCIS (Netherlands)

    Buijs, M. M.; Gorgels, J. P. M. C.; Endert, E.

    2011-01-01

    There are many causes of interference in immunoassays causing erratic patient results. A method-specific interference due to antiruthenium antibodies in Roche free thyroxine (fT4) and free triiodothyronine (fT3) assays has been described previously. As a result, a new generation fT4 assay has been

  7. 25-hydroxy-Vitamin D status: limitations in comparison and clinical interpretation of serum-levels across different assay methods.

    Science.gov (United States)

    Enko, Dietmar; Fridrich, Leo; Rezanka, Erwin; Stolba, Robert; Ernst, Juliane; Wendler, Iris; Fabian, Daniel; Hauptlorenz, Susanne; Halwachs-Baumann, Gabriele

    2014-01-01

    Background: Over the last decade, clinical interest to evaluate human 25-hydroxy-vitamin D (25[OH]D) serum levels has increased exponentially. In the present study, four chemiluminescence immunoassays (CLIA), one radioimmunoassy (RIA), and one high performance liquid chromatography (HPLC) method were compared and also with the liquid chromatography-tandem mass spectrometry (LC-MS/MS) method in view of 25(OH)D serum level determination. Methods: For the method comparison, blood samples from 133 consecutive patients were prospectively collected. All participants gave written informed consent for their blood samples to be used in this study. They came to the Department of Nuclear Medicine of the Central Hospital Steyr (Austria) for osteodensidometric measurement as part of their preventive medical check-up. Pearson's correlation coefficients, Bland-Altman plots, and paired t-tests were calculated. Assay-specific reference ranges were considered using blood samples from persons with normal parathormone, calcium, and total-protein values (n = 97). Results: The highest correlation was between the HPLC and the LC-MS/MS method (r = 0.96). The lowest correlation was between the cobas Vitamin D3 assay (Roche) and any of the evaluated assays (r = 0.46 - 0.63). Bland-Altman plots revealed a big negative mean bias in three assays (cobas Vitamin D3 assay [Roche]: -22.8; DiaSorin LIAISON [25[OH]D total CLIA [Diasorin]: -18.4; Diasorin 25[OH]D125 I RIA [Diasorin]: -23.8 [nmol/L]) and a much smaller positive mean bias in the other assays (ClinRep complete 25[OH]D2/D3 HPLC kit [Recipe]: 2.7; ADVIA Centaur Vitamin D total assay [Siemens]: 8.2; IDS total vitamin D assay [Immunodiagnostic Systems]: 12.1 [nmol/L]) compared to the LC-MS/MS method. Meanwhile, the manufacturer has withdrawn the cobas Vitamin D3 assay from the market. Conclusions: Poor antibody specificity with cross-reactivity to other vitamin D metabolites, incomplete extraction of the 25(OH)D analyte from the vitamin D

  8. Riemann-Roch Spaces and Linear Network Codes

    DEFF Research Database (Denmark)

    Hansen, Johan P.

    We construct linear network codes utilizing algebraic curves over finite fields and certain associated Riemann-Roch spaces and present methods to obtain their parameters. In particular we treat the Hermitian curve and the curves associated with the Suzuki and Ree groups all having the maximal...... number of points for curves of their respective genera. Linear network coding transmits information in terms of a basis of a vector space and the information is received as a basis of a possibly altered vector space. Ralf Koetter and Frank R. Kschischang %\\cite{DBLP:journals/tit/KoetterK08} introduced...... in the above metric making them suitable for linear network coding....

  9. On the Use of Roche Equipotentials in Analysing the Problems of ...

    Indian Academy of Sciences (India)

    expression for the potential has been used in subsequent analysis by var- ious authors to analyse ... (1983, 1985) used Kopal's concept of Roche equipotentials in conjunction with the averaging .... Using this value of. Keplerian ... In the present case D can be taken to be the outermost equilibrium radius of the undistorted ...

  10. SurePath Specimens Versus ThinPrep Specimen Types on the COBAS 4800 Platform: High-Risk HPV Status and Cytology Correlation in an Ethnically Diverse Bronx Population.

    Science.gov (United States)

    Naeem, R C; Goldstein, D Y; Einstein, Mark H; Ramos Rivera, G; Schlesinger, K; Khader, S N; Suhrland, M; Fox, A S

    2017-08-01

    To compare the cytologic preparations of 130 cervical specimens (from women of various ethnicities at high risk for human papillomavirus [HPV] infection) using the SurePath (SP) collection system with specimens gathered using the ThinPrep (TP) system, as processed on the Cobas 4800 analyzer, to determine which collection method more accurately identifies HPV infection. In our prospective study, specimens were collected from 130 women of various ethnicities residing in or near Bronx County, NY. The SP-collected specimen was first processed for cytologic findings; if clinical HPV testing was requested on that specimen, it was tested using Hybrid Capture II (HC2) methodology. We tested the remnant SP-collected cell concentrate using the Cobas analyzer. Then, the TP-collected and SP-collected specimens were tested in the same run on that analyzer, and the results were compared. We also compared the results with the concurrent cytologic findings. The results were concordant for overall HR-HPV status in 93.8% of cases. Also, a statistically significant lower cycle threshold value was observed with Cobas testing of specimen concentrates tested via the BD SurePath Pap Test (P = .001), suggesting higher sensitivity compared with specimens tested via the ThinPrep Pap Test. Cobas 4800 HPV testing of SP-collected specimen concentrates yields comparable results to TP-collected specimen concentrates. Based on the limited data that we derived, SP collection may be a more favorable methodology than TP collection for HPV testing of individuals at high risk in our ethnically diverse, urban patient population. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  11. Usutu virus infections among blood donors, Austria, July and August 2017 - Raising awareness for diagnostic challenges.

    Science.gov (United States)

    Bakonyi, Tamás; Jungbauer, Christof; Aberle, Stephan W; Kolodziejek, Jolanta; Dimmel, Katharina; Stiasny, Karin; Allerberger, Franz; Nowotny, Norbert

    2017-10-01

    Between July and August 2017, seven of 12,047 blood donations from eastern Austria, reacted positive to West Nile virus (WNV) in the cobas test (Roche). Follow-up investigations revealed Usutu virus (USUV) nucleic acid in six of these. Retrospective analyses of four blood donors diagnosed as WNV-infected in 2016 showed one USUV positive. Blood transfusion services and public health authorities in USUV-endemic areas should be aware of a possible increase of human USUV infections.

  12. A new primate assemblage from La Verrerie de Roches (Middle Eocene, Switzerland).

    Science.gov (United States)

    Minwer-Barakat, Raef; Marigó, Judit; Becker, Damien; Costeur, Loïc

    2017-12-01

    Primates reached a great abundance and diversity during the Eocene, favored by warm temperatures and by the development of dense forests throughout the Northern Hemisphere. Here we describe new primate material from La Verrerie de Roches, a Middle Eocene karstic infill situated in the Jura Region (Switzerland), consisting of more than 80 dental remains. The primate assemblage from La Verrerie de Roches includes five different taxa. The best represented primate is Necrolemur aff. anadoni, similar in size and overall morphology to Necrolemur anadoni but resembling in some features the younger species Necrolemur antiquus. Microchoerines are also represented by two species of Pseudoloris, P. pyrenaicus and Pseudoloris parvulus, constituting the unique joint record of these two species known up to now. Remains of Adapiformes are limited to one isolated tooth of a large anchomomyin and another tooth belonging to the small adapine Microadapis cf. sciureus. The studied primate association allows assigning La Verrerie de Roches to the Robiacian Land Mammal Age. More specifically, this site can be confidently situated between the MP15 and MP16 reference levels, although the primate assemblage probably indicates some degree of temporal mixing. This is the first record of P. pyrenaicus and a form closely related to N. anadoni out of the Iberian Peninsula. The identification of these microchoerines in Switzerland gives further support to the connection of NE Spain and Central Europe during the Middle Eocene. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Life near the Roche limit - Behavior of ejecta from satellites close to planets

    Science.gov (United States)

    Dobrovolskis, A. R.; Burns, J. A.

    1980-01-01

    A study of the dynamics of nearby debris from impact craters was made to explain the distinctive features seen on Phobos, Deimis, and Amalthea. The planetary tides and satellite rotation were considered, and the usual pseudo-energy (Jacobi) integral was numerically calculated in the framework of a restricted body problem where satellites are modelled as triaxial ellipsoids rather than point masses. Iso-contours of this integral show that Deimos and Amalthea are entirely closed by Roche lobes, and the surfaces of their model ellipsoids lie nearly along equipotentials. Presently, the surface of Phobos overflows its Roche lobe, except for regions within a few km of the sub-Mars and anti-Mars points. The behavior of crater ejecta from the satellites of Mars were also examined by numerical integration of trajectories for particles leaving their surfaces in the equatorial plane.

  14. Performance evaluation of new automated hepatitis B viral markers in the clinical laboratory: two quantitative hepatitis B surface antigen assays and an HBV core-related antigen assay.

    Science.gov (United States)

    Park, Yongjung; Hong, Duck Jin; Shin, Saeam; Cho, Yonggeun; Kim, Hyon-Suk

    2012-05-01

    We evaluated quantitative hepatitis B surface antigen (qHBsAg) assays and a hepatitis B virus (HBV) core-related antigen (HBcrAg) assay. A total of 529 serum samples from patients with hepatitis B were tested. HBsAg levels were determined by using the Elecsys (Roche Diagnostics, Indianapolis, IN) and Architect (Abbott Laboratories, Abbott Park, IL) qHBsAg assays. HBcrAg was measured by using Lumipulse HBcrAg assay (Fujirebio, Tokyo, Japan). Serum aminotransferases and HBV DNA were respectively quantified by using the Hitachi 7600 analyzer (Hitachi High-Technologies, Tokyo, Japan) and the Cobas AmpliPrep/Cobas TaqMan test (Roche). Precision of the qHBsAg and HBcrAg assays was assessed, and linearity of the qHBsAg assays was verified. All assays showed good precision performance with coefficients of variation between 4.5% and 5.3% except for some levels. Both qHBsAg assays showed linearity from 0.1 to 12,000.0 IU/mL and correlated well (r = 0.9934). HBsAg levels correlated with HBV DNA (r = 0.3373) and with HBcrAg (r = 0.5164), and HBcrAg also correlated with HBV DNA (r = 0.5198; P < .0001). This observation could provide impetus for further research to elucidate the clinical usefulness of the qHBsAg and HBcrAg assays.

  15. Automated processing, extraction and detection of herpes simplex virus types 1 and 2: A comparative evaluation of three commercial platforms using clinical specimens.

    Science.gov (United States)

    Binnicker, Matthew J; Espy, Mark J; Duresko, Brian; Irish, Cole; Mandrekar, Jay

    2017-04-01

    Recently, automated platforms have been developed that can perform processing, extraction and testing for herpes simplex virus (HSV) nucleic acid on a single instrument. In this study, we compared three commercially-available systems; Aptima ® /Panther (Hologic, San Diego, CA), ARIES ® (Luminex Corporation, Austin, TX), and cobas ® 4800 (Roche Molecular Systems Inc, Pleasanton, CA) for the qualitative detection of HSV-1/2 in clinical samples. Two-hundred seventy-seven specimens (genital [n=193], dermal [n=84]) were submitted for routine HSV-1/2 real-time PCR by a laboratory developed test. Following routine testing, samples were also tested by the Aptima, ARIES, and cobas HSV-1/2 assays per the manufacturer's recommendations. Results were compared to a "consensus standard" defined as the result obtained from ≥3 of the 4 assays. Following testing of 277 specimens, the cobas and ARIES assays demonstrated a sensitivity of 100% for HSV-1 (61/61) and HSV-2 (55/55). The Aptima assays showed a sensitivity of 91.8% (56/61) for HSV-1 and 90.9% (50/55) for HSV-2. Percent specificities for HSV-1 were 96.2% (202/210) by cobas, 99.5% (209/210) by ARIES and 100% (236/236) by Aptima. For HSV-2, the specificities were 98.1% (211/215) by cobas, 99.5% (215/216) by ARIES and 100% (216/216) by Aptima. The turnaround time for testing 24 samples was 2.5h by the cobas 4800, 3.1h by Aptima/Panther, and 3.9h by ARIES. The three commercial systems can perform all current functions on a single platform, thereby improving workflow and potentially reducing errors associated with manual processing of samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Alteration in sample preparation to increase the yield of multiplex Polymerase Chain Reaction assay for diagnosis of genital ulcer disease

    Directory of Open Access Journals (Sweden)

    G Rao

    2013-01-01

    Full Text Available Purpose: Genital Ulcer Disease (GUD is common sexually transmitted infection (STI. Multiple studies have shown that GUDs are strongly associated with the transmission and the acquisition of HIV infection. An accurate diagnosis of common etiology of GUD namely Herpes, syphilis and Chancroid is possible using Multiplex PCR (M-PCR. However, frequent presence of Polymerase Chain Reaction inhibitors in the ulcer swab specimen limits the performance of the assay. In order to overcome this problem, alternative specimen preparation method was used. Materials and Methods: To determine the common etiology, GUD specimens obtained under an STI operations research study were tested with M-PCR after the samples were prepared using Roche Amplicor specimen preparation kit. PCR inhibiting samples were identified from that, which showed negative results. These samples were subjected to phenol-chloroform extraction and ethanol precipitation before the conduct of M-PCR on them. Results: Of the 237 GUD specimens tested, in 145 etiologies could be detected, whereas 92 samples were found negative. Further spiking with one of the target DNA, 128 of the negative samples were found to contain the inhibitors. These 126 samples were then subjected to phenol chloroform extraction and ethanol precipitation followed by M-PCR. Using this method for sample preparation, etiology could be determined in 46 (23% additional samples. This success rate of altered sample preparation method has been lower than that has reported. Conclusion: The results indicate that sample preparation using phenol chloroform extraction and ethanol precipitation, prior to M-PCR helps to eliminate the inhibitors and increase the yield of the assay. However, being a laborious procedure, it may be used for samples giving negative results after the screening by Roche Amplicor specimen preparation kit.

  17. A European multicientre study on the comparison of HIV-1 viral loads between VERIS HIV-1 Assay and Roche COBAS® TAQMAN® HIV-1 test, Abbott RealTime HIV-1 Assay, and Siemens VERSANT HIV-1 Assay.

    Science.gov (United States)

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Hofmann, Jörg; Izopet, Jacques; Kühn, Sebastian; Lombardi, Alessandra; Mancon, Alessandro; Marcos, Mª Angeles; Mileto, Davide; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    2017-07-01

    Viral load monitoring is essential for patients under treatment for HIV. Beckman Coulter has developed the VERIS HIV-1 Assay for use on the novel, automated DxN VERIS Molecular Diagnostics System. ¥ OBJECTIVES: Evaluation of the clinical performance of the new quantitative VERIS HIV-1 Assay at multiple EU laboratories. Method comparison with the VERIS HIV-1 Assay was performed with 415 specimens at 5 sites tested with COBAS ® AmpliPrep/COBAS ® TaqMan ® HIV-1 Test, v2.0, 169 specimens at 3 sites tested with RealTime HIV-1 Assay, and 202 specimens from 2 sites tested with VERSANT HIV-1 Assay. Patient monitoring sample results from 4 sites were also compared. Bland-Altman analysis showed the average bias between VERIS HIV-1 Assay and COBAS HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay to be 0.28, 0.39, and 0.61 log 10 cp/mL, respectively. Bias at low end levels below 1000cp/mL showed predicted bias to be <0.3 log 10 cp/mL for VERIS HIV-1 Assay versus COBAS HIV-1 Test and RealTime HIV-1 Assay, and <0.5 log 10 cp/mL versus VERSANT HIV-1 Assay. Analysis on 174 specimens tested with the 0.175mL volume VERIS HIV-1 Assay and COBAS HIV-1 Test showed average bias of 0.39 log 10 cp/mL. Patient monitoring results using VERIS HIV-1 Assay demonstrated similar viral load trends over time to all comparators. The VERIS HIV-1 Assay for use on the DxN VERIS System demonstrated comparable clinical performance to COBAS ® HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Analytical validation of the Roche 25-OH Vitamin D Total assay

    DEFF Research Database (Denmark)

    Knudsen, Cindy Soendersoe; Nexo, Ebba; Højskov, Carsten Schriver

    2012-01-01

    ) showed Vitamin D Total nmol/L=1.07×(LC-MS/MS) nmol/L+4.7 nmol/L, whereas comparison of 25OHD2 using 23 patient samples showed Vitamin D Total nmol/L=0.55×(LC-MS/MS) nmol/L–2.38 nmol/L (Demings regression). Conclusions: The Roche Vitamin D Total assay is judged suitable for measurement of 25OHD in serum...

  19. Can the Roche hemolysis index be used for automated determination of cell-free hemoglobin? A comparison to photometric assays.

    Science.gov (United States)

    Petrova, Darinka Todorova; Cocisiu, Gabriela Ariadna; Eberle, Christoph; Rhode, Karl-Heinz; Brandhorst, Gunnar; Walson, Philip D; Oellerich, Michael

    2013-09-01

    The aim of this study was to develop a novel method for automated quantification of cell-free hemoglobin (fHb) based on the HI (Roche Diagnostics). The novel fHb method based on the HI was correlated with fHb measured using the triple wavelength methods of both Harboe [fHb, g/L = (0.915 * HI + 2.634)/100] and Fairbanks et al. [fHb, g/L = (0.917 * HI + 2.131)/100]. fHb concentrations were estimated from the HI using the Roche Modular automated platform in self-made and commercially available quality controls, as well as samples from a proficiency testing scheme (INSTAND). The fHb using Roche automated HI results were then compared to results obtained using the traditional spectrophotometric assays for one hundred plasma samples with varying degrees of hemolysis, lipemia and/or bilirubinemia. The novel method using automated HI quantification on the Roche Modular clinical chemistry platform correlated well with results using the classical methods in the 100 patient samples (Harboe: r = 0.9284; Fairbanks et al.: r = 0.9689) and recovery was good for self-made controls. However, commercially available quality controls showed poor recovery due to an unidentified matrix problem. The novel method produced reliable determination of fHb in samples without interferences. However, poor recovery using commercially available fHb quality control samples currently greatly limits its usefulness. © 2013.

  20. Strategy for the maximization of clinically relevant information from hepatitis C virus, RT-PCR quantification.

    LENUS (Irish Health Repository)

    Levis, J

    2012-02-03

    BACKGROUND: The increasing clinical application of viral load assays for monitoring viral infections has been an incentive for the development of standardized tests for the hepatitis C virus. OBJECTIVE: To develop a simple model for the prediction of baseline viral load in individuals infected with the hepatitis C virus. METHODOLOGY: Viral load quantification of each patient\\'s first sample was assessed by RT-PCR-ELISA using the Roche MONITOR assay in triplicate. Genotype of the infecting virus was identified by reverse line probe hybridization, using amplicons resulting from the qualitative HCV Roche AMPLICOR assay. RESULTS: Retrospective evaluation of first quantitative values suggested that 82.4% (n=168\\/204) of individuals had a viral load between 4.3 and 6.7 log(10) viral copies per ml. A few patients (3.4%; n=7\\/204) have a serum viremia less than the lower limit of the linear range of the RT-PCR assay. Subsequent, prospective evaluation of hepatitis C viral load of all new patients using a model based on the dynamic range of viral load in the retrospective group correctly predicted the dynamic range in 75.9% (n=33\\/54). CONCLUSION: The dynamic range of hepatitis C viremia extends beyond the linear range of the Roche MONITOR assay. Accurate determination of serum viremia is substantially improved by dilution of specimens prior to quantification.

  1. Operational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory.

    Science.gov (United States)

    Dhungana, Neha; Morris, Cory; Krasowski, Matthew D

    2017-08-01

    The aim of this study was to compare the operational impact of using vanadate oxidase versus diazo direct bilirubin assays for an academic medical center patient population. Retrospective study was done over an approximately 3.5 year period. The main automated chemistry instrumentation was a Roche Diagnostics cobas 8000 line. The Roche Direct Bilirubin assay was compared to Diazyme Laboratories Direct Bilirubin Assay and Randox Laboratories Direct Bilirubin assay using manufacturer's guidelines for hemolysis index, lipemia index, and analytical measurement range (AMR). Retrospective data was analyzed for 47,333 serum/plasma specimens that had clinical orders for direct bilirubin. A total of 5943 specimens (12.6%) exceeded the hemolysis index limit for the Roche method compared to only 0.2% and 0.05% of specimens for the Diazyme and Randox methods, respectively. The impact was particularly large on patients less than 2 years old, for which 51.3% of specimens exceeded the hemolysis index for the Roche method. A total of 1671 specimens (3.5%) exceeded the lipemia index limit for the Roche method compared to less than 0.1% for the Randox method. Lastly, 988 (2.1%) of specimens had direct bilirubin concentrations exceeding the upper AMR limit of 10 mg/dL [171 µmol/L] for the Roche assay compared to less than 1% of specimens for the vanadate oxidase methods. Vanadate oxidase direct bilirubin methods offer advantages over diazo methods in terms of less interference by hemolysis and lipemia, as well as wider AMR. The advantages are particularly evident for neonatal and infant populations.

  2. Use of Roche coordinates in the problems of small oscillations of tidally-distorted stellar models. II

    International Nuclear Information System (INIS)

    Mohan, C.; Singh, V.P.

    1979-01-01

    Kopal's method of Roche coordinates used by the authors in an earlier paper (Mohan and Singh, 1978) to study the problems of small oscillations of tidally-distorted stars has been extended further to take into account the effect of second-order terms in tidal distortion. The results show that the effect of including terms of second order of smallness in tidal distortion in the metric coefficients of the Roche coordinates of tidally distroted stars is quite significant, especially in case of stars with extended envelopes and (or) larger values of the companion star producing tidal distortion. Some of the models which were earlier found stable against small perturbations now become dynamically unstable with the inclusion of the terms of second order of smallness in tidal effects. (Auth.)

  3. Polyphony and counterpoint: Mechanisms of seduction in the diaries of Helen Hessel and Henri Pierre Roché

    Directory of Open Access Journals (Sweden)

    Catherine du Toit

    2015-06-01

    Polifonie en kontrapunt: Meganismes van verleiding in die dagboeke van Helen Hessel en Henri Pierre Roché. Henri Pierre Roché (1879–1959, outeur van Jules et Jim, word beskryf as ‘n sosiale koppelaar, ‘n model-liefhebber van alles en nog wat, ‘n versamelaar van vroue en kuns en een van die mees produktiewe dagboekskrywers en aktiewe minnaars in die opgetekende geskiedenis. Roché het ‘n reeks sketse oor Don Juan gepubliseer en was geboei deur die figuur van die verleier. In sy twintigs beplan hy om sy lewe te wy aan die skepping van ‘n œuvre wat die morele, intellektuele, sosiale en seksuele verhoudings tussen mans en vrouens sou ondersoek. Ter bereiking van hierdie doel, rig hy sy lewe in as laboratorium waarin werklike ondervindinge dien as hoofbron van inligting. Sy dagboek strek oor sestig jaar en is ryk aan verhale van verleiding. Desnieteenstaande bly die mees intense en boeiende intrige van verleiding en verraad steeds sy verhouding met Helen Hessel. Aan die begin van hulle verhouding, stel Roché voor dat sy ook ‘n dagboek hou van hulle hartstogtelike liefde. Helen Hessel se dagboek, geskryf in Frans, Duits en Engels, reflekteer die drama van verleiding en funksioneer op verskillende vlakke: realisties, visionêr, ten volle geabsorbeer in haar eie gedagtes en emosies en tóg krities jeens haarself en ander. ‘n Vergelyking van die twee dagboeke skep ‘n fassinerende, digte tekstuur wat die binnewerkings blootlê van verleiding in aksie. Die kontrapunt geskep deur hierdie twee interafhanklike stemme word nóg meer kompleks namate ‘n mens bewus word van die intertekstuele verwysings wat bydra tot die ontluikende polifonie van geskrewe liefde en lewe.

  4. Detection of EGFR mutations in plasma and biopsies from non-small cell lung cancer patients by allele-specific PCR assays

    DEFF Research Database (Denmark)

    Weber, Britta; Meldgaard, Peter; Hager, Henrik

    2014-01-01

    samples with allele-specific PCR assays. METHODS: Pairs of the diagnostic biopsy and plasma obtained just prior to start of erlotinib treatment were collected from 199 patients with adenocarcinoma of non-small-cell lung cancer. DNA from both sample types was isolated and examined for the presence...... of mutations in exons 18-21 of the EGFR gene, employing the cobas(®) EGFR Tissue Test and cobas(®) EGFR Blood Test (in development, Roche Molecular Systems, Inc., CA, USA). RESULTS: Test results were obtained in all 199 (100%) plasma samples and 196/199 (98%) of the biopsies. EGFR-activating mutations were...... identified in 24/199 (12%) plasma samples and 28/196 (14%) biopsy samples, and 17/196 (9%) matched pairs contained the same mutation. Six EGFR mutations were present only in plasma samples but not in the biopsy samples. The overall concordance of the EGFR gene mutations detected in plasma and biopsy tissue...

  5. Comparison of two immunoassay systems for hCGβ and PAPP-A in prenatal screening for trisomy 21, 18, and 13 in the first trimester

    DEFF Research Database (Denmark)

    Engell, Anna Elise; Carlsson, Elin Rebecka; Jørgensen, Finn Stener

    2017-01-01

    OBJECTIVES: The biochemical serum markers free β-human chorionic gonadotropin (hCGβ) and pregnancy associated plasma protein A (PAPP-A), used in screening for trisomy 21 (T21), trisomy 18 (T18), and trisomy 13 (T13) during the first trimester, can be measured on different laboratory instruments e.......g. Kryptor (Brahms) and Cobas (Roche). We compared the performance of these two analytical instruments when used for first trimester combined testing. DESIGN AND METHODS: Serum samples from 944 singleton pregnant women attending for first trimester combined testing were routinely assayed for hCGβ and PAPP...

  6. Fluorimetric methods for the measurement of intermediate metabolites (lactate, pyruvate, alanine, β-hydroxybutyrate, glycerol) using a COBAS FARA centrifugal analyser

    OpenAIRE

    Monti, L. D.; Sandoli, P. E.; Costa, S.; Phan, V. C.; Piatti, P. M.

    1993-01-01

    Intermediate products of the metabolism of glucose, fat and amino-acid are important in the evaluation of such metabolic disorders as diabetes mellitus, liver disease and metabolic acidosis. In the present study, methods for the measurement of intermediate metabolites (lactate, pyruvate, alanine, β-hydroxybutyrate and glycerol) have been adapted to a fast centrifugal analyzer: the COBAS FARA. Correlation coeffcients rangedfrom 0.90 to 0.99, compared to established manual spectrophotometric me...

  7. A Comparative Study for Detection of EGFR Mutations in Plasma Cell-Free DNA in Korean Clinical Diagnostic Laboratories

    Directory of Open Access Journals (Sweden)

    Yoonjung Kim

    2018-01-01

    Full Text Available Liquid biopsies to genotype the epidermal growth factor receptor (EGFR for targeted therapy have been implemented in clinical decision-making in the field of lung cancer, but harmonization of detection methods is still scarce among clinical laboratories. We performed a pilot external quality assurance (EQA scheme to harmonize circulating tumor DNA testing among laboratories. For EQA, we created materials containing different levels of spiked cell-free DNA (cfDNA in normal plasma. The limit of detection (LOD of the cobas® EGFR Mutation Test v2 (Roche Molecular Systems was also evaluated. From November 2016 to June 2017, seven clinical diagnostic laboratories participated in the EQA program. The majority (98.94% of results obtained using the cobas assay and next-generation sequencing (NGS were acceptable. Quantitative results from the cobas assay were positively correlated with allele frequencies derived from digital droplet PCR measurements and showed good reproducibility among laboratories. The LOD of the cobas assay was 5~27 copies/mL for p.E746_A750del (exon 19 deletion, 35~70 copies/mL for p.L858R, 18~36 copies/mL for p.T790M, and 15~31 copies/mL for p.A767_V769dup (exon 20 insertion. Deep sequencing of materials (>100,000X depth of coverage resulted in detection of low-level targets present at frequencies of 0.06~0.13%. Our results indicate that the cobas assay is a reliable and rapid method for detecting EGFR mutations in plasma cfDNA. Careful interpretation is particularly important for p.T790M detection in the setting of relapse. Individual laboratories should optimize NGS performance to maximize clinical utility.

  8. Operational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory

    Directory of Open Access Journals (Sweden)

    Neha Dhungana

    2017-08-01

    Full Text Available Objectives: The aim of this study was to compare the operational impact of using vanadate oxidase versus diazo direct bilirubin assays for an academic medical center patient population. Design and methods: Retrospective study was done over an approximately 3.5 year period. The main automated chemistry instrumentation was a Roche Diagnostics cobas 8000 line. The Roche Direct Bilirubin assay was compared to Diazyme Laboratories Direct Bilirubin Assay and Randox Laboratories Direct Bilirubin assay using manufacturer's guidelines for hemolysis index, lipemia index, and analytical measurement range (AMR. Results: Retrospective data was analyzed for 47,333 serum/plasma specimens that had clinical orders for direct bilirubin. A total of 5943 specimens (12.6% exceeded the hemolysis index limit for the Roche method compared to only 0.2% and 0.05% of specimens for the Diazyme and Randox methods, respectively. The impact was particularly large on patients less than 2 years old, for which 51.3% of specimens exceeded the hemolysis index for the Roche method. A total of 1671 specimens (3.5% exceeded the lipemia index limit for the Roche method compared to less than 0.1% for the Randox method. Lastly, 988 (2.1% of specimens had direct bilirubin concentrations exceeding the upper AMR limit of 10 mg/dL [171 µmol/L] for the Roche assay compared to less than 1% of specimens for the vanadate oxidase methods. Conclusions: Vanadate oxidase direct bilirubin methods offer advantages over diazo methods in terms of less interference by hemolysis and lipemia, as well as wider AMR. The advantages are particularly evident for neonatal and infant populations. Keywords: Bilirubin, Clinical chemistry tests, Hemolysis, Hyperlipidemias, Jaundice, Photometry

  9. Numerical Simulations of Gaseous Disks Generated from Collisional Cascades at the Roche Limits of White Dwarf Stars

    Science.gov (United States)

    Kenyon, Scott J.; Bromley, Benjamin C.

    2017-11-01

    We consider the long-term evolution of gaseous disks fed by the vaporization of small particles produced in a collisional cascade inside the Roche limit of a 0.6 {M}⊙ white dwarf. Adding solids with radius {r}0 at a constant rate {\\dot{M}}0 into a narrow annulus leads to two distinct types of evolution. When {\\dot{M}}0≳ {\\dot{M}}0,{crit}≈ 3× {10}4 {({r}0/1{km})}3.92 {{g}} {{{s}}}-1, the cascade generates a fairly steady accretion disk where the mass transfer rate of gas onto the white dwarf is roughly {\\dot{M}}0 and the mass in gas is {M}g≈ 2.3× {10}22 ({\\dot{M}}0/{10}10 {{g}} {{{s}}}-1) (1500 {{K}}/{T}0) ({10}-3/α ) g, where T 0 is the temperature of the gas near the Roche limit and α is the dimensionless viscosity parameter. If {\\dot{M}}0≲ {\\dot{M}}0,{crit}, the system alternates between high states with large mass transfer rates and low states with negligible accretion. Although either mode of evolution adds significant amounts of metals to the white dwarf photosphere, none of our calculations yield a vertically thin ensemble of solids inside the Roche limit. X-ray observations can place limits on the mass transfer rate and test this model for metallic line white dwarfs.

  10. CLSI-based transference of the CALIPER database of pediatric reference intervals from Abbott to Beckman, Ortho, Roche and Siemens Clinical Chemistry Assays: direct validation using reference samples from the CALIPER cohort.

    Science.gov (United States)

    Estey, Mathew P; Cohen, Ashley H; Colantonio, David A; Chan, Man Khun; Marvasti, Tina Binesh; Randell, Edward; Delvin, Edgard; Cousineau, Jocelyne; Grey, Vijaylaxmi; Greenway, Donald; Meng, Qing H; Jung, Benjamin; Bhuiyan, Jalaluddin; Seccombe, David; Adeli, Khosrow

    2013-09-01

    The CALIPER program recently established a comprehensive database of age- and sex-stratified pediatric reference intervals for 40 biochemical markers. However, this database was only directly applicable for Abbott ARCHITECT assays. We therefore sought to expand the scope of this database to biochemical assays from other major manufacturers, allowing for a much wider application of the CALIPER database. Based on CLSI C28-A3 and EP9-A2 guidelines, CALIPER reference intervals were transferred (using specific statistical criteria) to assays performed on four other commonly used clinical chemistry platforms including Beckman Coulter DxC800, Ortho Vitros 5600, Roche Cobas 6000, and Siemens Vista 1500. The resulting reference intervals were subjected to a thorough validation using 100 reference specimens (healthy community children and adolescents) from the CALIPER bio-bank, and all testing centers participated in an external quality assessment (EQA) evaluation. In general, the transferred pediatric reference intervals were similar to those established in our previous study. However, assay-specific differences in reference limits were observed for many analytes, and in some instances were considerable. The results of the EQA evaluation generally mimicked the similarities and differences in reference limits among the five manufacturers' assays. In addition, the majority of transferred reference intervals were validated through the analysis of CALIPER reference samples. This study greatly extends the utility of the CALIPER reference interval database which is now directly applicable for assays performed on five major analytical platforms in clinical use, and should permit the worldwide application of CALIPER pediatric reference intervals. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  11. A European multicientre study on the comparison of HBV viral loads between VERIS HBV assay and Roche COBAS® TAQMAN® HBV test, Abbott RealTime HBV assay, Siemens VERSANT HBV assay, and Qiagen artus HBV RG kit.

    Science.gov (United States)

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Izopet, Jacques; Lombardi, Alessandra; Marcos, MaAngeles; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    2017-10-01

    Hepatitis B viral load testing is essential to treatment and monitoring decisions in patients with chronic Hepatitis B. Beckman Coulter has developed the VERIS HBV Assay (Veris) for use on the fully automated DxN VERIS Molecular Diagnostics System. 1 OBJECTIVES: To evaluate the clinical performance of the Veris HBV Assay at multiple EU laboratories STUDY DESIGN: Method comparison was performed with a total of 344 plasma specimens from HBV infected patients tested with Veris and COBAS ® TaqMan ® HBV Test (Cobas), 207 specimens tested with Veris and RealTime HBV Assay (RealTime), 86 specimens tested with Veris and VERSANT ® HBV Assay (Versant), and 74 specimens tested with Veris and artus ® HBV RG PCR kit (artus). Bland-Altman analysis showed average bias of -0.46 log 10 IU/mL between Veris and Cobas, -0.46 log 10 IU/mL between Veris and RealTime, -0.36 log 10 IU/mL between Veris and Versant, and -0.12 log 10 IU/mL between Veris and artus. Bias was consistent across the assay range. Patient monitoring results using Veris demonstrated similar viral load trends over time to Cobas, RealTime, and artus. The VERIS HBV Assay demonstrated comparable clinical performance, with varying degrees of negative bias, compared to other currently marketed assays for HBV DNA monitoring. This negative bias should be taken into consideration if switching monitoring methods to Veris. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. The geometry of the eclipse of a pointlike star by a Roche-lobe-filling companion

    International Nuclear Information System (INIS)

    Chanan, G.A.; Middleditch, J.; Nelson, J.E.

    1976-01-01

    For binary systems of this type, which may be representative of certain X-ray sources, the eclipse duration defines a relation between the mass ratio and orbital inclination of the system; we have derived and tabulated this relation. Eclipse geometry for binary systems in which both stars fill their Roche lobes is also discussed briefly

  13. Racialized Spaces in Teacher Discourse: A Critical Discourse Analysis of Place-Based Identities in Roche Bois, Mauritius

    Science.gov (United States)

    Wiehe, Elsa M.

    2013-01-01

    This eleven-month ethnographic study puts critical discourse analysis in dialogue with postmodern conceptualizations of space and place to explore how eight educators talk about space and in the process, produce racialized spaces in Roche Bois, Mauritius. The macro-historical context of racialization of this urban marginalized community informs…

  14. Real-time PCR assays for hepatitis B virus DNA quantification may require two different targets.

    Science.gov (United States)

    Liu, Chao; Chang, Le; Jia, Tingting; Guo, Fei; Zhang, Lu; Ji, Huimin; Zhao, Junpeng; Wang, Lunan

    2017-05-12

    Quantification Hepatitis B virus (HBV) DNA plays a critical role in the management of chronic HBV infections. However, HBV is a DNA virus with high levels of genetic variation, and drug-resistant mutations have emerged with the use of antiviral drugs. If a mutation caused a sequence mismatched in the primer or probe of a commercial DNA quantification kit, this would lead to an underestimation of the viral load of the sample. The aim of this study was to determine whether commercial kits, which use only one pair of primers and a single probe, accurately quantify the HBV DNA levels and to develop an improved duplex real-time PCR assay. We developed a new duplex real-time PCR assay that used two pairs of primers and two probes based on the conserved S and C regions of the HBV genome. We performed HBV DNA quantitative detection of HBV samples and compared the results of our duplex real-time PCR assays with the COBAS TaqMan HBV Test version 2 and Daan real-time PCR assays. The target region of the discordant sample was amplified, sequenced, and validated using plasmid. The results of the duplex real-time PCR were in good accordance with the commercial COBAS TaqMan HBV Test version 2 and Daan real-time PCR assays. We showed that two samples from Chinese HBV infections underestimated viral loads when quantified by the Roche kit because of a mismatch between the viral sequence and the reverse primer of the Roche kit. The HBV DNA levels of six samples were undervalued by duplex real-time PCR assays of the C region because of mutations in the primer of C region. We developed a new duplex real-time PCR assay, and the results of this assay were similar to the results of commercial kits. The HBV DNA level could be undervalued when using the COBAS TaqMan HBV Test version 2 for Chinese HBV infections owing to a mismatch with the primer/probe. A duplex real-time PCR assay based on the S and C regions could solve this problem to some extent.

  15. Evaluation, including effects of storage and repeated freezing and thawing, of a method for measurement of urinary creatinine

    DEFF Research Database (Denmark)

    Garde, A H; Hansen, Åse Marie; Kristiansen, J

    2003-01-01

    The aims of this study were to elucidate to what extent storage and repeated freezing and thawing influenced the concentration of creatinine in urine samples and to evaluate the method for determination of creatinine in urine. The creatinine method was based on the well-known Jaffe's reaction...... and measured on a COBAS Mira autoanalyser from Roche. The main findings were that samples for analysis of creatinine should be kept at a temperature of -20 degrees C or lower and frozen and thawed only once. The limit of detection, determined as 3 x SD of 20 determinations of a sample at a low concentration (6...

  16. Glucose meters: evaluation of the new formulation measuring strips from Roche (Accu-Chek) and Abbott (MediSense).

    Science.gov (United States)

    Dimeski, G; Jones, B W; Tilley, V; Greenslade, M N; Russell, A W

    2010-07-01

    Both Roche and Abbott have released new glucose meter strips. They supply the entire Australian hospital market. The present study compared the performance of the new strips utilizing various specimen types (capillary, venous lithium heparin whole blood, venous lithium heparin plasma and serum) and evaluated how well they comply with the International Standards Organization (ISO) 15197 criteria. The study included imprecision, patient comparison and interference studies. Participants with and without diabetes were recruited to evaluate the performance of various specimen types against the Beckman DxC800 glucose method. The strips were tested for different interferences: galactose, maltose, lactose, Icodextrin, Intragam, paracetamol, sodium, ascorbic acid, variable strip storage temperature, haematocrit, haemolysis and lipaemia. The imprecision of the two strips was approximately 5% or less, except for the Abbott strip at very low values (1.4 mmol/L), approximately 7%. In total, 78% and 84%, respectively, of the results from the finger prick capillary specimens with the Roche (Accu-Chek Performa meter) and Abbott (Optium Xceed meter) strips, not 95% or greater as recommended by the ISO guideline, were within the recommended limits compared with reference plasma estimation on laboratory analysers. Galactose, ascorbic acid, haematocrit and sodium on the Roche and ascorbic acid and haematocrit on the Abbott strip continue to interfere to a variable degree with the glucose measurement. Analytically small differences exist between the glucose meter strips. The most significant analytical difference with the strips was at low glucose levels when compared with laboratory analyses and this may be of clinical importance. The impact of some of the interferences is variable between the two strips. Individuals, health-care professionals and health-care institutions should consider these data when selecting glucose meters for the management of people with diabetes mellitus.

  17. High-throughput sequencing of core STR loci for forensic genetic investigations using the Roche Genome Sequencer FLX platform

    DEFF Research Database (Denmark)

    Fordyce, Sarah Louise; Avila Arcos, Maria del Carmen; Rockenbauer, Eszter

    2011-01-01

    repeat units. These methods do not allow for the full resolution of STR base composition that sequencing approaches could provide. Here we present an STR profiling method based on the use of the Roche Genome Sequencer (GS) FLX to simultaneously sequence multiple core STR loci. Using this method...

  18. Early Biochemical Screening for Fetal Aneuploidy in the First Trimester

    DEFF Research Database (Denmark)

    Tørring, Niels

    2013-01-01

    Background Screening for fetal trisomy 21 in the first trimester includes analysis of the serological markers pregnancy-associated plasma protein A (PAPP-A) and free beta human choriogonadotropin (free βhCG). With the recent launch of the PAPP-A free βhCG and assays on the Roche Cobas and Elecsys...... assays showed slopes of 0.94 and 0.95 and Pearson’s correlation of r = 0.981 and r = 0.987 respectively. Similar comparison to AutoDELFIA PerkinElmer Perkin gave slopes of 0,83 (free βhCG) and 1.20 (PAPP-A). With a cut off at 1:300 the overall sensitivity of the first trimester screening including nuchal...

  19. Autoradiography in Studying the Alteration of Rocks; L'Autoradiographie dans l'Etude de l'Alteration des Roches

    Energy Technology Data Exchange (ETDEWEB)

    Leveque, P.; Vigneaux, M. [Institut de Geologie du Bassin d' Aquitaine, Faculte des Sciences de l' Universite de Bordeaux (France)

    1967-06-15

    The alteration of rocks intended for use as the foundations of large-scale civil-engineering projects, for building construction and for rock piling has been studied and numerous tests carried out; some of these tests have been standardized in varying degrees. The conventional method of autoradiography has been used to develop one of the processes for estimating alteration due, in particular, to thermal shocks. By using {sup 35}S and {sup 32}P, the authors were able to follow the progressive alteration of different rocks in the form of microfissurations. This process is considerably more accurate than that based solely on utilization of the characteristics of rocks in normal or polarized light. In addition, it permits absolute comparison of the initial microfissuration conditions of the sample and the microfissuration found after an increasing number of thermal shock cycles. The results of the process are given in the paper. (author) [French] L'alterabilite des roches destinees, soit a des fondations de grands travaux de genie civil, soit a la construction d'immeubles, soit enfin a l'etablissement d'enrochements, a fait l'objet de nombreux essais dont certains ont ete normalises, ou tout au moins ont subi un debut de normalisation. Un des procedes de determination du processus d'alteration du notamment aux chocs thermiques a ete mis au point a partir de la methode classique d'autoradiographie. L'utilisation de {sup 35}S et de {sup 32}P a permis de suivre la progression de l'alteration par microfissuration dans des roches diverses. Ce procede est notablement plus precis que celui qui est fonde sur la seule utilisation des caracteristiques des roches en lumiere naturelle ou polarisee. De plus, il permet la comparaison en valeur absolue de l'etat de microfissuration initial de l'echantillon avec la microfissuration obtenue apres un nombre croissant de cycles de chocs thermiques. Les resultats obtenus grace a ce procede sont donnes dans le memoire. (author)

  20. Performance of the new automated Abbott RealTime MTB assay for rapid detection of Mycobacterium tuberculosis complex in respiratory specimens.

    Science.gov (United States)

    Chen, J H K; She, K K K; Kwong, T-C; Wong, O-Y; Siu, G K H; Leung, C-C; Chang, K-C; Tam, C-M; Ho, P-L; Cheng, V C C; Yuen, K-Y; Yam, W-C

    2015-09-01

    The automated high-throughput Abbott RealTime MTB real-time PCR assay has been recently launched for Mycobacterium tuberculosis complex (MTBC) clinical diagnosis. This study would like to evaluate its performance. We first compared its diagnostic performance with the Roche Cobas TaqMan MTB assay on 214 clinical respiratory specimens. Prospective analysis of a total 520 specimens was then performed to further evaluate the Abbott assay. The Abbott assay showed a lower limit of detection at 22.5 AFB/ml, which was more sensitive than the Cobas assay (167.5 AFB/ml). The two assays demonstrated a significant difference in diagnostic performance (McNemar's test; P = 0.0034), in which the Abbott assay presented significantly higher area under curve (AUC) than the Cobas assay (1.000 vs 0.880; P = 0.0002). The Abbott assay demonstrated extremely low PCR inhibition on clinical respiratory specimens. The automated Abbott assay required only very short manual handling time (0.5 h), which could help to improve the laboratory management. In the prospective analysis, the overall estimates for sensitivity and specificity of the Abbott assay were both 100 % among smear-positive specimens, whereas the smear-negative specimens were 96.7 and 96.1 %, respectively. No cross-reactivity with non-tuberculosis mycobacterial species was observed. The superiority in sensitivity of the Abbott assay for detecting MTBC in smear-negative specimens could further minimize the risk in MTBC false-negative detection. The new Abbott RealTime MTB assay has good diagnostic performance which can be a useful diagnostic tool for rapid MTBC detection in clinical laboratories.

  1. Roche and IAEA announce joint initiative to train healthcare workers for Africa's fight against cancer. EDUCARE partnership to launch IAEA's VUCCnet training networks

    International Nuclear Information System (INIS)

    2010-01-01

    Full text: Roche and the International Atomic Energy Agency (IAEA) announced today the launch of the EDUCARE (EDUcation for Cancer in African REgions) project to provide concerted support to help combat the growing cancer epidemic in sub-Saharan Africa. The EDUCARE project is to be piloted in Ghana, Tanzania, Uganda and Zambia, and is linked with the IAEA's wider initiative to build regional training networks in cancer control and a Virtual University for Cancer Control (VUCCnet) in Africa. A core component for the successful fight against cancer in any country is the education and training of health care providers. The VUCCnet will allow for training to be provided in an integrated and sustainable way in Africa by taking advantage of low-cost online learning tools. The IAEA is working in collaboration with the World Health Organization (WHO) and other international partners to develop the VUCCnet across Africa. The EDCUARE project will facilitate a first-of-its-kind exchange of knowledge and skills, both at the healthcare provider and country-wide level. Training will be provided by an on-line training resource centre, known as the Virtual University for Cancer Control (VUCC), the first such platform for health workers across the continent. Maturin Tchoumi, General Manager Roche South Africa said: 'As a leader in oncology, Roche believes that its strengths, expertise and resources can be used to improve the quality of oncology training and education in the poorest countries in the world. There is a real lack of basic education in oncology in Africa. By contributing our skills and competencies on the ground, Roche can make a real and sustainable improvement.' This new public-private partnership reflects a shared concern over the increasing cancer burden in sub-Saharan Africa, a region of the world where cancer rates are growing rapidly. Cancer now accounts for 12.5% of all deaths worldwide, more than HIV/AIDS, TB and malaria combined. By 2020, there are expected to

  2. Tipo de respuesta según el genotipado del virus del papiloma humano según cobas 4800 en las lesiones asc-us HPV positivas

    OpenAIRE

    Kanjou Augé, Nadwa

    2016-01-01

    Objetivos: Evaluar el riesgo de patología subyacente en las pacientes ASC-US HPV positivas de nuestra área de influencia analizadas por el método COBAS 4800. Se estudió el riesgo de CIN2+ en el momento del diagnóstico de las mujeres ASC-US HPV positivas según el genotipo del virus del papiloma: HPV16, HPV18 ( ambos incluyendo coinfecciones) u otros HPV de alto riesgo (HR-HPV). El objetivo es detectar aquellas mujeres con citologías ASC-US HPV positivo con un mayor riesgo de progresión y por l...

  3. Detection of Mycobacterium tuberculosis Complex in Paraffin-Embedded Tissues by the New Automated Abbott RealTime MTB Assay.

    Science.gov (United States)

    Fu, Yung-Chieh; Liao, I-Chuang; Chen, Hung-Mo; Yan, Jing-Jou

    2016-07-01

    The Abbott RealTime MTB assay, launched in June 2014, has been shown to have a competitive performance in the detection of the Mycobacterium tuberculosis (MTB) complex in respiratory specimens. The present study was conducted to investigate the usefulness of the Abbott MTB Realtime assay in the detection of MTB in formalin-fixed paraffin-embedded (FFPE) tissues. A total of 96 FFPE specimens obtained from microbiologically proven MTB cases (N=60) and nontuberculous Mycobacterium cases (N=36) were analyzed. The performance of the Abbott MTB Realtime assay was compared with that of the Roche Cobas TaqMan MTB assay. The overall sensitivity and specificity of the Abbott assay were 63.3% and 97.2%, respectively, compared with 11.7% and 100% for the Cobas assay. The detection rate of the Abbott assay was much higher among 37 acid-fast-positive specimens than among 23 acid-fast-negative specimens (89.3% versus 21.7%, respectively). The detection rate of the assay was higher among 29 resection specimens than among 31 small biopsy specimens (86.2% versus 41.9%, respectively). Our results suggest that the Abbott RealTime MTB assay can be used to differentiate MTB from nontuberculous mycobacterial infections in acid-fast-positive FFPE tissues. © 2016 by the Association of Clinical Scientists, Inc.

  4. Evaluation of the Correlation Coefficient of Polyethylene Glycol Treated and Direct Prolactin Results and Comparability with Different Assay System Results.

    Science.gov (United States)

    Pal, Shyamali

    2017-12-01

    The presence of Macro prolactin is a significant cause of elevated prolactin resulting in misdiagnosis in all automated systems. Poly ethylene glycol (PEG) pretreatment is the preventive process but such process includes the probability of loss of a fraction of bioactive prolactin. Surprisingly, PEG treated EQAS & IQAS samples in Cobas e 411 are found out to be correlating with direct results of at least 3 immunoassay systems and treated and untreated Cobas e 411 results are comparable by a correlation coefficient. Comparison of EQAS, IQAS and patient samples were done to find out the trueness of such correlation factor. Study with patient's results have established the correlation coefficient is valid for very small concentration of prolactin also. EQAS, IQAS and 150 patient samples were treated with PEG and prolactin results of treated and untreated samples obtained from Roche Cobas e 411. 25 patient's results (treated) were compared with direct results in Advia Centaur, Architect I & Access2 systems. Correlation coefficient was obtained from trend line of the treated and untreated results. Two tailed p-value obtained from regression coefficient(r) and sample size. The correlation coefficient is in the range (0.761-0.771). Reverse correlation range is (1.289-1.301). r value of two sets of calculated results were 0.995. Two tailed p- value is zero approving dismissal of null hypothesis. The z-score of EQAS does not always assure authenticity of resultsPEG precipitation is correlated by the factor 0.761 even in very small concentrationsAbbreviationsGFCgel filtration chromatographyPEGpolyethylene glycolEQASexternal quality assurance systemM-PRLmacro prolactinPRLprolactinECLIAelectro-chemiluminescence immunoassayCLIAclinical laboratory improvement amendmentsIQASinternal quality assurance systemrregression coefficient.

  5. Impact of pH on Urine Chemistry Assayed on Roche Analyzers.

    Science.gov (United States)

    Cohen, R; Alkouri, R; Tostivint, I; Djiavoudine, S; Mestari, F; Dever, S; Atlan, G; Devilliers, C; Imbert-Bismut, F; Bonnefont-Rousselot, D; Monneret, D

    2017-10-01

    The pH may impact the concentration of certain urinary parameters, making urine pre-treatment questionable. 1) Determining the impact of pH in vitro on the urinary concentration of chemistry parameters assayed on Roche Modular analyzers. 2) Evaluating whether concentrations depended on pH in non-pretreated urines from patients. 1) The optimal urinary pH values for each measurement were: 6.3 ± 0.8 (amylase), 6.5 (uric acid). Urinary creatinine, sodium and urea concentrations were not pH-dependent. 2) In urines from patients, the pH was negatively associated with the concentration of some urinary parameters. However, concentrations of all the parameters were strongly and positively correlated with urinary creatinine, and relationships with pH were no longer evidenced after creatinine-normalization. The need for urine pH adjustment does not seem necessary when considering renal function. However, from an analytical and accreditation standpoint, the relationship between urine pH and several parameters justifies its measurement.

  6. Detection of HPV-DNA by a PCR-based method in formalin-fixed, paraffin-embedded tissue from rare endocervical carcinoma types.

    Science.gov (United States)

    Nofech-Mozes, Sharon; Khalifa, Mahmoud M; Ismiil, Nadia; Dubé, Valerie; Saad, Reda S; Sun, Peizhu; Seth, Arun; Ghorab, Zeina

    2010-01-01

    High-risk human papilloma virus (HPV) seems to play a role in the pathogenesis of cervical squamous neoplasia and adenocarcinomas of the mucinous and endometrioid cell types. Cervical serous, clear cell, and small cell carcinomas differ from the conventional endocervical adenocarcinoma in their clinical characteristics. The data on the role of HPV in their pathogenesis are limited. In this study, we examined the presence of high-risk HPV-DNA in rare types of cervical carcinoma using polymerase chain reaction-based test. In-house cervical serous, clear cell, and small cell carcinoma cases accessioned between 2000 and 2008 were tested for HPV by polymerase chain reaction amplification of DNA extracted from deparaffinized sections using Roche AMPLICOR HPV Amplification Detection and Control Kits. The kit detects all 13 high-risk HPV-DNA genotypes. The positive cut-off point for AMPLICOR HPV Test was A450 = 0.2. We identified 4 serous, 3 clear cell, 1 mixed clear cell and serous, and 5 small cell carcinomas. High-risk HPV-DNA tested positive in 3 out of 4 serous carcinomas, 2 out of 3 cervical clear cell carcinomas, and all 5 cases of small cell carcinoma and the mixed cell type. Our report documents HPV status in a series of archival unusual types of adenocarcinoma of the uterine cervix. It suggests a robust association between high-risk HPV and these rare subtypes. Despite their unique clinical setting and morphologic appearance, the majority of these tumors likely share a common HPV-mediated carcinogenic pathway. Our observation is particularly significant in cervical cancer prevention as we enter the HPV vaccination era.

  7. Simultaneous detection of five different DNA targets by real-time Taqman PCR using the Roche LightCycler480: Application in viral molecular diagnostics

    NARCIS (Netherlands)

    Molenkamp, Richard; van der Ham, Alwin; Schinkel, Janke; Beld, Marcel

    2007-01-01

    One of the most interesting aspects of real-time PCR based on the detection of fluorophoric labeled oligonucleotides is the possibility of being able to detect conveniently multiple targets in the same PCR reaction. Recently, Roche Diagnostics launched a real-time PCR platform, the LightCycler480

  8. Direct comparisons of Illumina vs. Roche 454 sequencing technologies on the same microbial community DNA sample.

    Science.gov (United States)

    Luo, Chengwei; Tsementzi, Despina; Kyrpides, Nikos; Read, Timothy; Konstantinidis, Konstantinos T

    2012-01-01

    Next-generation sequencing (NGS) is commonly used in metagenomic studies of complex microbial communities but whether or not different NGS platforms recover the same diversity from a sample and their assembled sequences are of comparable quality remain unclear. We compared the two most frequently used platforms, the Roche 454 FLX Titanium and the Illumina Genome Analyzer (GA) II, on the same DNA sample obtained from a complex freshwater planktonic community. Despite the substantial differences in read length and sequencing protocols, the platforms provided a comparable view of the community sampled. For instance, derived assemblies overlapped in ~90% of their total sequences and in situ abundances of genes and genotypes (estimated based on sequence coverage) correlated highly between the two platforms (R(2)>0.9). Evaluation of base-call error, frameshift frequency, and contig length suggested that Illumina offered equivalent, if not better, assemblies than Roche 454. The results from metagenomic samples were further validated against DNA samples of eighteen isolate genomes, which showed a range of genome sizes and G+C% content. We also provide quantitative estimates of the errors in gene and contig sequences assembled from datasets characterized by different levels of complexity and G+C% content. For instance, we noted that homopolymer-associated, single-base errors affected ~1% of the protein sequences recovered in Illumina contigs of 10× coverage and 50% G+C; this frequency increased to ~3% when non-homopolymer errors were also considered. Collectively, our results should serve as a useful practical guide for choosing proper sampling strategies and data possessing protocols for future metagenomic studies.

  9. Les granites sodiques et les roches associées de l'ophiolite de Chamrousse-Tabor et du groupe de Rioupéroux-Livet ( Isère-France) - Pétrochimie et géochimie .

    OpenAIRE

    Scarenzi , Denis

    1984-01-01

    Les roches leucocrates du massif UB-B de Chamrousse - Tabor sont intrusives au sommet de la séquence ophiolitique et y sont associées à des gabbros cumulats, des ferrogabbros, des basaltes et des dolérites. Ces roches correspondent à des cumulats plagioclastiques (albitites et anorthosites), des diorites quartziques, des tonalltes et des leucotonalites. . Des diorites quartziques, tonalites et leucotonalites sont également présentes dans le groupe de Séchilienne. Elles y sont accompagnées par...

  10. Skin Microbiome in Patients With Psoriasis Before and After Balneotherapy at the Thermal Care Center of La Roche-Posay.

    Science.gov (United States)

    Martin, Richard; Henley, Jessica B; Sarrazin, Patrick; Seité, Sophie

    2015-12-01

    Changes in the composition of microbial communities that colonize skin have been linked to several diseases including psoriasis. Nevertheless, the intra-individual dynamics and how these communities respond to balneotherapy remain poorly understood. This open label study was conducted between July and September 2012. Microbial communities of patients with psoriasis vulgaris were characterized prior and post a 3-week selenium-rich water balneotherapy treatment at the thermal care center La Roche-Posay (La Roche-Posay, France). Balneotherapy consisted of high-pressure filiform showers, baths, facial, and body spray treatments as well as La Roche-Posay thermal spring water (LRP-TSW) consumption. Swabs were taken from affected and proximal unaffected skin and the 16S rRNA bacterial gene was used to analyze the composition of bacterial communities. Using the same 16S rRNA gene tool, we tried to describe the LRP-TSW bacterial landscape. This study included 54 patients diagnosed with moderate to severe forms of psoriasis vulgaris. After eliminating individuals lacking paired samples from both visits, 29 individuals were analyzed for their microbiome profile. Shannon Diversity Index and global bacterial landscape indicate similar microbial communities on both unaffected and adjacent affected skin. PASI values decreased post-balneotherapy implying improvement of disease severity. No significant change in the Shannon Diversity Index was noticed at the end of the third week. The average taxonomic composition of skin microbial communities associated with unaffected and affected skin of psoriatic patients post-balneotherapy shows that treatment with LRP-TSW significantly increased the level of Xanthomonas genus and, to a lesser extent, Corynebacterium genus. The Xanthomonas genus belongs to the main Xanthomonadaceae family found in LRP-TSW and also on healthy skin. In psoriatic patients, a poor bacterial biodiversity was noticed and the bacterial communities were similar on

  11. Usefulness of nucleic acid testing to reduce risk of hepatitis B virus transfusion-transmitted infection in Argentina: high rate of recent infections.

    Science.gov (United States)

    Blanco, Sebastián; Balangero, Marcos César; Valle, Mildre Cledy; Montini, Oscar Luis; Carrizo, Luis Horacio; Gallego, Sandra Verónica

    2017-03-01

    Results from 10-year experience using nucleic acid test (NAT) screening in a blood bank of Córdoba are presented, showing the first data on prevalence of recent hepatitis B virus (HBV) infections and occult HBV infections (OBIs) in Argentina. Molecular screening was performed by COBAS AmpliScreen human immunodeficiency virus Type 1 (HIV-1) test Version 1.5 and COBAS AmpliScreen hepatitis C virus (HCV) test Version 2.0 and COBAS TaqScreen MPX and MPX Version 2.0 test (Roche Molecular Systems). To characterize OBI, additional molecular and serologic assays were performed. As results of NAT, 0.075% of the donors (155/205,388) tested positive for HIV, 0.05% (106/205,388) for HCV, and 0.045% (76/168,215) for HBV. Donors who tested positive for HIV or HCV by NAT were also positive by serology. There was one of 33,643 donors recently infected with HBV. At time of donation, six of 76 (7.9%) donors with confirmed HBV infection presented virologic and serologic profiles consistent with OBI. By additional studies three were OBI, two were window period infections, and one remained unclassified. NAT contributed significantly to the reduction of the potential risk of HBV transmission with a frequency of one in 56,072, detecting three in 168,215 donors without serologic evidence of infection. NAT also detected three in 168,215 OBIs. The finding of high frequency of recent infections (1/33,643), unexpected for this country, highlights the need of promoting unified effective regulations that enforce the use of NAT in all blood banks in Argentina and points out the importance of assessing the risk of HBV transmission in blood banks of other countries considered to be low-endemic. © 2016 AABB.

  12. One window-period donation in two years of individual donor-nucleic acid test screening for hepatitis B, hepatitis C and human immunodeficiency virus

    Directory of Open Access Journals (Sweden)

    Jose Eduardo Levi

    2013-06-01

    Full Text Available Objective: To describe general data on nucleic acid/serology testing and report the first hepatitis B-nucleic acid testing yield case of an immunized donor in Brazil. Methods: A total of 24,441 donations collected in 2010 and 2011 were submitted to individual nucleic acid testing for hepatitis B, hepatitis C and human immunodeficiency virus using the TaqMan® MPX kit (Roche on the Cobas s201 platform, in addition to routine screening for serological markers. Nucleic acid testing-reactive donations were further evaluated by real-time polymerase chain reaction using Cobas AmpliPrep/Cobas TaqMan hepatitis B virus, hepatitis C virus and human immunodeficiency virus tests. Results: Thirty-two donations were reactive by nucleic acid testing, 31 were also serologically reactive and one first-time donor was identified as having hepatitis B in the window period. Follow-up samples showed increasing titers of anti-HBs rising from 19 UI/mL in the index donation to 109 IU/mL seven months later attributable to his vaccination history. Curiously, this donor was never reactive for HbsAg nor for anti-HBc. In the yield donation, he was concomitantly reactive for syphilis (enzyme immunoassay and fluorescent treponemal antibody-absorption; venereal disease research laboratory non-reactive. Overall, six donors (0.02% were characterized as occult hepatitis B. A total of 35% of the confirmed (recombinant immunoblot assay positive hepatitis C donations were nucleic acid testing non-reactive and no human immunodeficiency virus "elite controller" was identified. Conclusion: The yield rate (1:24,441; 95% confidence interval: 1:9,537 - 1:89,717 contrasts to the North American rate (1:410,540 donations and strongly advocates the adoption of nucleic acid testing for hepatitis B in Brazil despite the increasing rate of anti-HBs reactive subjects due to the successful immunization program.

  13. Direct comparisons of Illumina vs. Roche 454 sequencing technologies on the same microbial community DNA sample.

    Directory of Open Access Journals (Sweden)

    Chengwei Luo

    Full Text Available Next-generation sequencing (NGS is commonly used in metagenomic studies of complex microbial communities but whether or not different NGS platforms recover the same diversity from a sample and their assembled sequences are of comparable quality remain unclear. We compared the two most frequently used platforms, the Roche 454 FLX Titanium and the Illumina Genome Analyzer (GA II, on the same DNA sample obtained from a complex freshwater planktonic community. Despite the substantial differences in read length and sequencing protocols, the platforms provided a comparable view of the community sampled. For instance, derived assemblies overlapped in ~90% of their total sequences and in situ abundances of genes and genotypes (estimated based on sequence coverage correlated highly between the two platforms (R(2>0.9. Evaluation of base-call error, frameshift frequency, and contig length suggested that Illumina offered equivalent, if not better, assemblies than Roche 454. The results from metagenomic samples were further validated against DNA samples of eighteen isolate genomes, which showed a range of genome sizes and G+C% content. We also provide quantitative estimates of the errors in gene and contig sequences assembled from datasets characterized by different levels of complexity and G+C% content. For instance, we noted that homopolymer-associated, single-base errors affected ~1% of the protein sequences recovered in Illumina contigs of 10× coverage and 50% G+C; this frequency increased to ~3% when non-homopolymer errors were also considered. Collectively, our results should serve as a useful practical guide for choosing proper sampling strategies and data possessing protocols for future metagenomic studies.

  14. Aprovechamiento del salto de Bourg-Lés-Valence. La Presa de la Roche de Glun-Drôme – Francia

    Directory of Open Access Journals (Sweden)

    Française d´Enterprise, Compagnie

    1971-05-01

    Full Text Available To take the fullest advantage of the hydroelectric and agricultural usefulness of the Rhône, the Compagnie Nationale du Rhône has divided the river into a number of sections, and these have been separately developed. The hydraulic gradient at La Roche de Glun, at the end of the central section, involves a hydraulic system consisting of a reservoir, a dam and dykes, a canal, a power station, an overflow canal and drainage works in the , surrounding zones. This project has been carried out by the Compagnie Française d'Enterprises.Para explotar al máximo las posibilidades hidroeléctricas y agrícolas del Ródano, la Compagnie Nationale du Rhône ha dividido dicho río en una serie de tramos para proceder a su distribución. El salto de La Roche de Glun, último del tramo central, forma un complejo hidráulico que consta de: un embalse cerrado por diques, una presa, un canal de alimentación, una central, una esclusa, un canal de descarga y unas obras anejas de drenaje para evitar inundaciones en las ciudades próximas. Las obras han sido realizadas por la Compagnie Française d'Entreprises.

  15. Testing single-grain quartz OSL methods using sediment samples with independent age control from the Bordes-Fitte rockshelter (Roches d'Abilly site, Central France)

    DEFF Research Database (Denmark)

    Thomsen, Kristina Jørkov; Murray, Andrew Sean; Buylaert, Jan-Pieter

    2016-01-01

    We present quartz single-grain dose distributions for four well-bleached and unmixed sediment samples with independent age control (22–48 ka), from the archaeologically important Bordes-Fitte rockshelter at Roches d'Abilly, France. This site has previously been dated using 14C AMS dating and stan...

  16. THE QUASI-ROCHE LOBE OVERFLOW STATE IN THE EVOLUTION OF CLOSE BINARY SYSTEMS CONTAINING A RADIO PULSAR

    Energy Technology Data Exchange (ETDEWEB)

    Benvenuto, O. G.; De Vito, M. A. [Facultad de Ciencias Astronómicas y Geofísicas, Universidad Nacional de La Plata and Instituto de Astrofísica de La Plata (IALP), CCT-CONICET-UNLP. Paseo del Bosque S/N (B1900FWA), La Plata (Argentina); Horvath, J. E., E-mail: adevito@fcaglp.unlp.edu.ar, E-mail: foton@iag.usp.br [Instituto de Astronomia, Geofísica e Ciências Atmosféricas, Universidade de São Paulo R. do Matão 1226 (05508-090), Cidade Universitária, São Paulo SP (Brazil)

    2015-01-01

    We study the evolution of close binary systems formed by a normal (solar composition), intermediate-mass-donor star together with a neutron star. We consider models including irradiation feedback and evaporation. These nonstandard ingredients deeply modify the mass-transfer stages of these binaries. While models that neglect irradiation feedback undergo continuous, long-standing mass-transfer episodes, models including these effects suffer a number of cycles of mass transfer and detachment. During mass transfer, the systems should reveal themselves as low-mass X-ray binaries (LMXBs), whereas when they are detached they behave as binary radio pulsars. We show that at these stages irradiated models are in a Roche lobe overflow (RLOF) state or in a quasi-RLOF state. Quasi-RLOF stars have radii slightly smaller than their Roche lobes. Remarkably, these conditions are attained for an orbital period as well as donor mass values in the range corresponding to a family of binary radio pulsars known as ''redbacks''. Thus, redback companions should be quasi-RLOF stars. We show that the characteristics of the redback system PSR J1723-2837 are accounted for by these models. In each mass-transfer cycle these systems should switch from LMXB to binary radio pulsar states with a timescale of approximately one million years. However, there is recent and fast growing evidence of systems switching on far shorter, human timescales. This should be related to instabilities in the accretion disk surrounding the neutron star and/or radio ejection, still to be included in the model having the quasi-RLOF state as a general condition.

  17. Performance of the new Bayer VERSANT HCV RNA 3.0 assay for quantitation of hepatitis C virus RNA in plasma and serum: Conversion to international units and comparison with the Roche COBAS amplicor HCV monitor, version 2.0, assay

    NARCIS (Netherlands)

    Beld, Marcel; Sentjens, Roel; Rebers, Sjoerd; Weegink, Christine; Weel, Jan; Sol, Cees; Boom, René

    2002-01-01

    We have evaluated the VERSANT HCV RNA 3.0. Assay (HCV 3.0 bDNA assay) (Bayer Diagnostics, Berkeley, Calif.), which is an improved signal amplification procedure for the HCV 2.0 bDNA assay for the quantitation of hepatitis C virus (HCV) RNA in serum or plasma of HCV-infected individuals. The HCV 3.0

  18. 10Be dating of the Main Terrace level in the Amblève valley (Ardennes, Belgium): new age constraint on the archaeological and palaeontological filling of the Belle-Roche palaeokarst

    Science.gov (United States)

    Rixhon, Gilles; Bourlès, Didier L.; Braucher, Régis; Siame, Lionel; Cordy, Jean-Marie; Demoulin, Alain

    2014-05-01

    It is still disputed whether very old archaeological and palaeontological remains found in the Belle-Roche palaeocave (eastern Belgium) pertain to the Early (˜1 Ma) or Middle (˜0.5 Ma) Pleistocene. Here, in situ-produced cosmogenic 10Be concentrations from a depth profile in nearby sediments of the Belle-Roche terrace (Amblève Main Terrace level) are used as an indirect solution of this chronological issue. The distribution of 10Be concentrations in the upper 3 m of this profile displays the theoretically expected exponential decrease with depth. Assuming a single exposure episode, we obtain a best fit age of 222.5±31 ka for the time of terrace abandonment. However, below 3 m, the 10Be concentrations show a marked progressive increase with depth. This distinctive cosmogenic signal is interpreted as the result of slow aggradation of the fluvial deposits over a lengthy interval. Modelling of the whole profile thus suggests that the onset of the terrace formation occurred at around 550 ka, with a sediment accumulation rate of ˜20 mm/ka. Based on two slightly different reconstructions of the geomorphic evolution of the area and a discussion of the temporal link between the cave and Main Terrace levels, we conclude that the fossil-bearing layers in the palaeokarst pertain most probably to MIS 14-13 (or possibly MIS 12-11) and the artifact-bearing layer to MIS 13 (or possibly MIS 11). This age estimate for the large mammal association identified in the Belle-Roche palaeokarst and the attribution to MIS 14-13 of a similar fauna found in the lowermost fossiliferous layers of the Caune de l'Arago (Tautavel) are in mutual support. Our results therefore confirm the status of the Belle-Roche site as a reference site for the Cromerian mammal association and the Early Palaeolithic industry in NW Europe.

  19. Short communication: identification of a novel HIV type 1 subtype H/J recombinant in Canada with discordant HIV viral load (RNA) values in three different commercial assays.

    Science.gov (United States)

    Kim, John E; Beckthold, Brenda; Chen, Zhaoxia; Mihowich, Jennifer; Malloch, Laurie; Gill, Michael John

    2007-11-01

    The presence of HIV-1 non-B subtypes is increasing worldwide. This poses challenges to commercial diagnostic and viral load (RNA) monitoring tests that are predominantly based on HIV-1 subtype B strains. Based on phylogenetic analysis of the gag, pol, and env gene regions, we describe the first HIV-1 H/J recombinant in Canada that presented divergent viral load values. DNA sequence analysis of the gag gene region further revealed that genetic diversity between this H/J recombinant and the primers and probes used in the bio-Merieux Nuclisens HIV-1 QT (Nuclisens) and Roche Amplicor Monitor HIV-1, v1.5 (Monitor) viral RNA assays can erroneously lead to undetectable viral load values. This observation appears to be more problematic in the Nuclisens assay. In light of increasing genetic diversity in HIV worldwide we recommend that DNA sequencing of HIV, especially in the gag gene region targeted by primers and probes used in molecular diagnostic and viral load tests, be incorporated into clinical monitoring practices.

  20. Characterization of the scope and magnitude of biotin interference in susceptible Roche Elecsys competitive and sandwich immunoassays.

    Science.gov (United States)

    Trambas, Christina; Lu, Zhong; Yen, Tina; Sikaris, Ken

    2018-03-01

    Background Biotin interference is a significant problem to which at-risk laboratories must now be attuned. We sought to systematically characterize the nature of this interference in Roche immunoassays. Methods Known concentrations of biotin were titrated into serum samples and the effects on competitive and sandwich immunoassays were analysed. The maximum and minimum concentrations examined reflect those likely to be achieved in individuals on 5 to 10 mg supplements at the lower end, and 100 to 300 mg biotin at the high end. Results A high variability in biotin tolerance was observed. Some assays, such as troponin T, TSH and antithyroid antibodies, were extremely sensitive to the lower concentrations of biotin (15.6 and 31.3 ng/mL), whereas the majority of assays were relatively resistant. At concentrations ≥500 ng/mL, all assays showed significant interference from biotin but, again, the magnitude of the interference was variable. The more sensitive assays showed profound analytical bias at biotin concentrations that occur with high-dose therapy. Conclusion Our data demonstrate high variability in biotin tolerance across Roche immunoassays. The shape of the dose-response curves provides more detailed information than the single manufacturer-quoted figure for biotin tolerance. Accordingly, these data may be used by laboratories for more accurate risk assessment in predicting the effects of biotin. Our data may also be extrapolated to guide timing of blood tests in patients on high-dose biotin therapy: it demonstrates the number of half-lives required to withhold biotin in order to decrease its concentration to below a given assay tolerance.

  1. From Roche Vitamins to DSM Nutritional Products%从罗氏维生素到帝斯曼营养产品

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    In October 2003, the Dutch group DSM has acquired the Vitamins and Fine Chemicals business from Roche to create DSM Nutritional Products-one of the world's leading suppliers of vitamins and carotenoids for Animal Nutrition industry, the Food and Pharmaceutical industries as well as the Cosmetics industry by offering a wide range of products to help improve nutrition and prevent disease. In China market, B vitamins are provided by DSM Nutritional Products for food fortification.

  2. Chlamydia trachomatis ompA genotypes in male patients with urethritis in Greece: conservation of the serovar distribution and evidence for mixed infections with Chlamydophila abortus.

    Science.gov (United States)

    Psarrakos, Panagiotis; Papadogeorgakis, Eleni; Sachse, Konrad; Vretou, Evangelia

    2011-08-01

    PCR amplification and nucleotide sequencing of the ompA gene of Chlamydia trachomatis were used to determine the prevalence and distribution of genotypes in 51 urine and urethral specimens from Greek male patients with urethritis, that were positive by the COBAS Amplicor test. A single C. trachomatis serovar was identified in 43 of the 51 amplified samples. Serovars F and E were the most prevalent (both 12, 28%), followed by D (9, 21%), G (4, 9%), B and K (both 2, 5%) and H and J (both 1, 2%). Over one third of the samples bared a variant ompA genotype that had been previously identified in other areas worldwide. Two results in this study, both observed for the first time, were of particular interest. First, the emergence of the unique variant genotype D/Ep6 (X77364.2) identified in 3 urethral samples. Second, the ompA genotype OCLH196 of the animal pathogen Chlamydophila abortus as well as a 23S rRNA gene fragment of this species detected by the assay ArrayTube™ was found in 7 urethral samples. The implications resulting from this observation for the health of the general population are discussed. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. De Sébastien Roch à L’agneau chaste ou de la construction à la déconstruction de la matrice romanesque de la pédophilie

    Directory of Open Access Journals (Sweden)

    Szczur Przemysław

    2015-12-01

    Full Text Available L’obiettivo del presente articolo è di paragonare l’immagine della pedofilia in due romanzi : Sébastien Roch di Octave Mirbeau e L’agneau chaste di Franck Varjac. Mentre il primo ha contribuito a costruire la matrice romanzesca della pedofilia, il secondo prova a decostruirla.

  4. Transfusion transmittable infections - Seroprevalence among blood donors in a tertiary care hospital of Delhi

    Directory of Open Access Journals (Sweden)

    Sangeeta Pathak

    2013-01-01

    Full Text Available Context: Transfusion transmittable infections (TTI continue to be a major threat to safe transfusion practices. Blood is one of the major sources of transmission of infectious diseases viz. human immunodeficiency virus (HIV, hepatitis B virus (HBV, hepatitis C virus (HCV, syphilis, malaria, and many other infections in India. Screening assays for the infectious diseases with excellent sensitivity and specificity helps to enhance the safety of the blood transfusions reducing the diagnostic window period as much as possible. Aims: The present study was designed to determine the seroprevalence of TTIs viz., HIV, HCV, and HBV, among the blood donors in Max Super Specialty Hospital, New Delhi, India based on dual testing strategy using high sensitive screening assays such as enhanced chemiluminescence assay and nucleic acid testing (NAT. Materials and Methods: A total of 41207 blood units collected from the donors (both voluntary and replacement donors were screened for the TTI s, viz., anti HIV 1 and 2 antibody, anti HCV antibody, anti HBcore antibody, and HBsAg by enhanced chemiluminescence assay on VITROS ® ECiQ immunodiagnostics system. NAT was performed using Roche Cobas ® TaqScreen MPX assay, which can detect simultaneously HIV 1 (groups M and O, HIV-2, HCV, and HBV on Roche Cobas ® s201 system. Results: The seroprevalence of HIV, HBsAg, anti HBcore antibody, and HCV based on enhanced chemiluminescence assay was found to be 0.25, 0.2, 7.06, and 0.7%, respectively. A total number of 6587 samples from July 2010 to December 2010 were tested on NAT, of which 3 samples were reactive for HBV in NAT; this was missed by enhanced chemiluminescence assay. Conclusions: Based on the seroprevalence study of infectious diseases viz., HIV, HBV, and HCV, we conclude that screening of blood and blood components by dual testing strategy using high sensitivity serological assay like enhanced chemiluminescence technology and NAT helps in detecting the

  5. Point of care testing of fecal calprotectin as a substitute for routine laboratory analysis

    DEFF Research Database (Denmark)

    Hejl, Julie; Theede, Klaus; Møllgren, Brian

    2018-01-01

    Objectives Fecal calprotectin (FC) is widely used to monitor the activity of inflammatory bowel disease (IBD) and to tailor medical treatment to disease activity. Laboratory testing of fecal samples may have a turnaround time of 1–2 weeks, whereas FC home testing allows results within hours...... and thus enables a rapid response to clinical deterioration. Design and methods Fifty-five stool samples were analyzed by the IBDoc® Calprotectin Home Testing kit and the BÜHLMANN fCAL® turbo assay on a Roche Cobas 6000 c501. The correlation between the assays was assessed using Spearman's Rho correlation...... coefficient and the intermediate imprecision of both assays was calculated. Results We found a strong correlation coefficient of 0.887 between FC measured on IBDoc® and the laboratory assay BÜHLMANN fCAL® turbo. The coefficients of variation (CVs) at three different FC levels were in the range 2...

  6. Comparative evaluation of three automated systems for DNA extraction in conjunction with three commercially available real-time PCR assays for quantitation of plasma Cytomegalovirus DNAemia in allogeneic stem cell transplant recipients.

    Science.gov (United States)

    Bravo, Dayana; Clari, María Ángeles; Costa, Elisa; Muñoz-Cobo, Beatriz; Solano, Carlos; José Remigia, María; Navarro, David

    2011-08-01

    Limited data are available on the performance of different automated extraction platforms and commercially available quantitative real-time PCR (QRT-PCR) methods for the quantitation of cytomegalovirus (CMV) DNA in plasma. We compared the performance characteristics of the Abbott mSample preparation system DNA kit on the m24 SP instrument (Abbott), the High Pure viral nucleic acid kit on the COBAS AmpliPrep system (Roche), and the EZ1 Virus 2.0 kit on the BioRobot EZ1 extraction platform (Qiagen) coupled with the Abbott CMV PCR kit, the LightCycler CMV Quant kit (Roche), and the Q-CMV complete kit (Nanogen), for both plasma specimens from allogeneic stem cell transplant (Allo-SCT) recipients (n = 42) and the OptiQuant CMV DNA panel (AcroMetrix). The EZ1 system displayed the highest extraction efficiency over a wide range of CMV plasma DNA loads, followed by the m24 and the AmpliPrep methods. The Nanogen PCR assay yielded higher mean CMV plasma DNA values than the Abbott and the Roche PCR assays, regardless of the platform used for DNA extraction. Overall, the effects of the extraction method and the QRT-PCR used on CMV plasma DNA load measurements were less pronounced for specimens with high CMV DNA content (>10,000 copies/ml). The performance characteristics of the extraction methods and QRT-PCR assays evaluated herein for clinical samples were extensible at cell-based standards from AcroMetrix. In conclusion, different automated systems are not equally efficient for CMV DNA extraction from plasma specimens, and the plasma CMV DNA loads measured by commercially available QRT-PCRs can differ significantly. The above findings should be taken into consideration for the establishment of cutoff values for the initiation or cessation of preemptive antiviral therapies and for the interpretation of data from clinical studies in the Allo-SCT setting.

  7. Numerical Simulations of Collisional Cascades at the Roche Limits of White Dwarf Stars

    Science.gov (United States)

    Kenyon, Scott J.; Bromley, Benjamin C.

    2017-08-01

    We consider the long-term collisional and dynamical evolution of solid material orbiting in a narrow annulus near the Roche limit of a white dwarf. With orbital velocities of 300 {km} {{{s}}}-1, systems of solids with initial eccentricity e≳ {10}-3 generate a collisional cascade where objects with radii r ≲ 100{--}300 {km} are ground to dust. This process converts 1-100 km asteroids into 1 μm particles in 102-106 yr. Throughout this evolution, the swarm maintains an initially large vertical scale height H. Adding solids at a rate \\dot{M} enables the system to find an equilibrium where the mass in solids is roughly constant. This equilibrium depends on \\dot{M} and {r}0, the radius of the largest solid added to the swarm. When {r}0 ≲ 10 km, this equilibrium is stable. For larger {r}0, the mass oscillates between high and low states; the fraction of time spent in high states ranges from 100% for large \\dot{M} to much less than 1% for small \\dot{M}. During high states, the stellar luminosity reprocessed by the solids is comparable to the excess infrared emission observed in many metallic line white dwarfs.

  8. Quantitation of human immunodeficiency virus type 1 in breast milk.

    Science.gov (United States)

    Ghosh, M K; Kuhn, L; West, J; Semrau, K; Decker, D; Thea, D M; Aldrovandi, G M

    2003-06-01

    The distribution and stability of human immunodeficiency virus type 1 (HIV-1) in breast milk (BM) components remain largely unknown. Inhibitory effects, if any, of BM on HIV RNA and DNA PCR amplification are poorly understood. We have addressed these issues by using virus-spiked BM samples from HIV-negative women. BM samples from HIV-negative women were spiked with HIV-1 virions or cells containing a single integrated copy of HIV DNA (8E5/LAV). After incubation under different experimental conditions, viral RNA was detected by the Roche Amplicor UltraSensitive assay in whole-milk, skim milk, and lipid fractions. We found excellent correlation between HIV-1 input copy and recovery in whole milk (r = 0.965, P milk (r = 0.972, P 0.982). The effects of incubation duration and temperature and repeated freeze-thaw cycles on HIV RNA recovery were analyzed. HIV RNA levels were remarkably stable in whole milk after three freeze-thaw cycles and for up to 30 h at room temperature. Our findings improve the understanding of the dynamics of HIV detection in BM and the conditions for BM sample collection, storage, and processing.

  9. Persistence of hepatitis C virus in a white population: associations with human leukocyte antigen class 1.

    LENUS (Irish Health Repository)

    Fanning, Liam J

    2012-02-03

    The aim of this study was to define novel associations between human leukocyte antigen (HLA) class 1 alleles and persistence or clearance of the hepatitis C virus (HCV) in a white population. All individuals in the study were seropositive for anti-HCV antibodies. Viral status was determined by the Roche HCV Amplicor test. HLA-A, -B, -C allelic group profile was molecularly defined by reverse line probe hybridization. The strongest individual allelic group associations with persistent HCV infection were HLA A*11 (p = 0.044) and Cw*04 (p = 0.006). However, only the HLA C*04 association survived correction for multiple comparisons. Further analysis of alleles in linkage with HLA Cw*04 revealed that the haplotype HLA A*11, Cw*04 was present in 11 individuals, 10 of whom were viremic (p = 0.05). No gene dosage effect was observed. No association between HLA class 1 allelic groups and aviremia and virus load was evident in this white population. HLA B*44 is associated with low virus load in human immunodeficiency virus disease, but this association was not evident in this HCV-infected population. Novel HLA class 1 alleles associated with persistence of HCV have been identified.

  10. Cytology and Human Papillomavirus Testing 6 to 12 Months after ASCUS or LSIL Cytology in Organized Screening To Predict High-Grade Cervical Neoplasia between Screening Rounds

    Science.gov (United States)

    Sjøborg, Katrine D.; Nygård, Mari; Røysland, Kjetil; Campbell, Suzanne; Alfsen, G. Cecilie; Jonassen, Christine M.

    2012-01-01

    We carried out a prospective study comparing the performance of human papillomavirus (HPV) E6/E7 mRNA (PreTect HPV-Proofer; NorChip, Klokkarstua, Norway) and DNA (Amplicor HPV test; Roche Diagnostics, Basel, Switzerland) triage testing of women 6 to 12 months after atypical-squamous-cells-of-undetermined-significance (ASCUS) or low-grade-squamous-intraepithelial-lesion (LSIL) cytology in organized screening to predict high-grade cervical intraepithelial neoplasia of grade 2 or worse (CIN2+) between screening rounds. Between January 2005 and April 2008, 692 study women with screening-detected ASCUS/LSIL cytology 6 to 12 months earlier returned for HPV mRNA and DNA testing and repeat cytology. The median follow-up time was 3 years, using existing health care facilities. Follow-up test results were available for 625 women. Of the 145 CIN2+ cases detected during the study period, 95 (65.5%) were HPV mRNA positive 6 to 12 months after screening-detected ASCUS/LSIL, 44 (30.4%) were HPV mRNA negative, and 6 (4.1%) were invalid. The corresponding HPV DNA results were 139 (95.9%), 5 (3.4%), and 1 (0.7%), respectively. The cumulative incidences of CIN2+ 3 years after a negative HPV mRNA and DNA test were 10.3% (95% confidence interval [CI], 7.2 to 13.3%) and 1.8% (95% CI, 0.0 to 3.6%), respectively. The cumulative incidences of CIN2+ 3 years after positive HPV mRNA and DNA tests were 52.8% (95% CI, 40.1 to 60.1%) and 41.3% (95% CI, 35.5 to 46.6%), respectively. In conclusion, both positive HPV mRNA and DNA test results have a high enough long-term prediction of CIN2+ risk to consider referral to colposcopy as good practice when performed in delayed triage of women with ASCUS/LSIL cytology. In addition, the low CIN2+ risk among women with a negative Amplicor HPV test in our study confirms its safe use in a clinical setting. PMID:22518869

  11. Strong negative interference of ethamsylate (Dicynone®) in serum creatinine quantification via enzymatic assay using Trinder reaction.

    Science.gov (United States)

    Wiewiorka, Ondrej; Dastych, Milan; Čermáková, Zdenka

    2013-08-01

    With discrepancies encountered as early as the verification of enzymatic method for quantification of serum creatinine, our research pointed to a later confirmed interference caused by a compound called ethamsylate present in the commonly used antihemorrhagic drug Dicynone. We measured concentrations of creatinine of 10 patients with blood taken before and 15 minutes after the intravenous administration of a 500 mg dose of Dicynone. The creatinine concentration was determined using Jaffe method and enzymatic method that utilize Trinder reaction (Roche) in analyzer Cobas c 501 (Roche AG, Basel, Switzerland). We also monitored concentration of blood creatinine in three patients before and 15 minutes after application of Dicynone (500 mg i.v.) and in the following 6th, 12th, 18th, and 24th hours. We discovered a significant negative bias in creatinine results using enzymatic assay with Trinder reaction in blood taken 15 min after i.v. application of 500 mg Dicynone to patients compared to their pre-application values (average decrease of 47%). Unlike this, the results of compensated Jaffe method yielded steady results in all samples (average deviation 0.6% from original values). However, 12 h after the drug administration comparable results were seen as before the administration. Considering the strong negative interference of ethamsylate in enzymatic assay using Trinder reaction for creatinine quantification, blood from patients with prescribed Dicynone should be taken at least 12 h after the last application of the drug for obtaining the correct creatinine values.

  12. Time-Motion Analysis of Four Automated Systems for the Detection of Chlamydia trachomatis and Neisseria gonorrhoeae by Nucleic Acid Amplification Testing.

    Science.gov (United States)

    Williams, James A; Eddleman, Laura; Pantone, Amy; Martinez, Regina; Young, Stephen; Van Der Pol, Barbara

    2014-08-01

    Next-generation diagnostics for Chlamydia trachomatis and Neisseria gonorrhoeae are available on semi- or fully-automated platforms. These systems require less hands-on time than older platforms and are user friendly. Four automated systems, the ABBOTT m2000 system, Becton Dickinson Viper System with XTR Technology, Gen-Probe Tigris DTS system, and Roche cobas 4800 system, were evaluated for total run time, hands-on time, and walk-away time. All of the systems evaluated in this time-motion study were able to complete a diagnostic test run within an 8-h work shift, instrument setup and operation were straightforward and uncomplicated, and walk-away time ranged from approximately 90 to 270 min in a head-to-head comparison of each system. All of the automated systems provide technical staff with increased time to perform other tasks during the run, offer easy expansion of the diagnostic test menu, and have the ability to increase specimen throughput. © 2013 Society for Laboratory Automation and Screening.

  13. Quantification of the value of C-reactive protein and its relationship with periodontal disease and cardiovascular risk in a sample of patients from the Facultad de Odontologia de la Universidad de Costa Rica: preliminary study

    International Nuclear Information System (INIS)

    Bermudez Mora, Gustavo; Gonzalez Leon, Yerlin; Jimenez Hernandez, Melissa; Padron Giraldino, Lieny; Rojas Villagra, Andrea

    2013-01-01

    Plasma P-CR concentration was measured and the value obtained was related to the presence and severity of periodontal and cardiovascular disease. A cross-sectional descriptive study was carried out, with the sample of 30 patients of different gender, age, type of periodontal disease and systemic condition. A serological test was performed on the subjects and analyzed quantitatively, using the measuring parameter of the Roche / Hitachi cobas 111 device, which automatically calculates the concentration of the P-CR in each sample. The results lack a statistically significant relationship of gender, age or degree of periodontal disease. The average value of P-CR was obtained from the study (3.72 mg / L) corresponds to a high risk of cardiovascular disease based on the parameters established by the American Heart Association. The only significant factor was the presence of associated systemic diseases in patients with high levels of P-CR, in comparison with those who suffer from some type of ailment. (author) [es

  14. Evaluation of the highly sensitive Roche thyroglobulin II assay and establishment of a reference limit for thyroglobulin-negative patient samples

    Directory of Open Access Journals (Sweden)

    Dorien M. Rotteveel-de Groot

    2016-08-01

    Full Text Available Objectives: Thyroglobulin (Tg measurements are used to monitor for residual thyroid tissue in patients with differentiated thyroid cancer (DTC after thyroidectomy and radioiodine ablative therapy. In recent years highly sensitive Tg assays have been developed. In this study the analytical performance of the new Roche Elecsys Tg II assay was evaluated and compared with the well documented Access2 Tg assay (Beckman–Coulter. Design and methods: Analytical performance was examined using various Clinical and Laboratory Standards Institute (CLSI evaluation protocols. Tg negative patient sera were used to establish an upper reference limit (URL for the Elecsys Tg II assay. Results: Non-linearity, drift and carry-over according to CLSI EP10 and EP6 in a measuring range of 0.04–500 ng/mL were non-significant. Total precision according to CLSI EP5 was 10% at a Tg concentration of 0.08 ng/mL. A patient serum comparison performed according to a modified CLSI EP9 protocol showed a significant difference of a factor of approximately 1.4, despite using an identical CRM calibrator. The Elecsys Tg II assay measured Tg with a two-fold higher sensitivity than the Access2 assay. Finally, using human sera without Tg, an URL of 0.05 ng/mL was determined. Conclusions: In our hands the highly sensitive Elecsys Tg II assay shows a good analytical performance and a higher sensitivity compared to the Access2 Tg assay. An URL of 0.05 ng/mL for the Elecsys Tg II assay was determined which may improve the clinical utility of the assay for the detection of residual DTC or disease recurrence. Keywords: Thyroglobulin, Roche Elecsys Tg II assay, validation, reporting limit

  15. Robe's Restricted Problem of 2 + 2 Bodies with a Roche Ellipsoid - Triaxial System

    Science.gov (United States)

    Aggarwal, Rajiv; Kaur, Bhavneet; Yadav, Sushil

    2018-03-01

    This paper investigates the motion of two infinitesimal masses on the location and stability of the equilibrium points in Robe's restricted problem of 2 + 2 bodies with the bigger primary a Roche ellipsoid and the smaller a triaxial body. We suppose the bigger primary of mass m 1 to be filled with a homogeneous incompressible fluid of density ρ 1. The third and the fourth bodies (of mass m 3 and m 4 respectively) are small solid spheres of density ρ 3 and ρ 4 respectively inside the ellipsoid, with the assumption that the mass and the radius of the third and the fourth body are infinitesimal. We assume that m 2 is describing a circle around m 1. The masses m 3 and m 4 mutually attract each other, do not influence the motion of m 1 and m 2 but are influenced by them. We have taken into consideration all the three components of the pressure field in deriving the expression for the buoyancy force viz (i) due to the own gravitational field of the fluid (ii) that originating in the attraction of m 2 (iii) that arising from the centrifugal force. In this paper, equilibrium solutions of m 3 and m 4 and their linear stability are analyzed.

  16. The Bolivian Source Rocks. Sub Andean Zone. Madre de Dios. Chaco Les roches mères de Bolivie. Subandin. Madre de Dios. Chaco

    Directory of Open Access Journals (Sweden)

    Diaz Martinez E.

    2006-11-01

    connaissances sur les roches mères de Bolivie. Ce travail a été fait dans le cadre de la convention de coopération qui lie depuis 1987 YPFB et l'ORSTOM - Institut Français de Recherche Scientifique pour le Développement en Coopération. L'établissement de cette base de données a permis une synthèse du potentiel pétrolier du pays, la partie concernant le bassin de Madre de Dios, la zone subandine et le Chaco, c'est-à-dire toute la zone potentiellement pétrolière du pays, hors Altiplano, est ici présentée. La base contient actuellement les analyses d'un peu plus de 3000 échantillons. Les roches mères sont Paléozoïques et se sont déposées dans un contexte de bassin d'avant-pays; celui ci s'étendait sur la cordillère ainsi que sur l'avant-pays actuel du Silurien au Permien. Le bassin, restreint initialement à la zone sud-ouest, s'est ensuite étendu vers le nord. La bordure ouest n'est pas connue, elle devait se situer au niveau de l'Altiplano actuel. La bordure est correspond au bouclier Brésilien affleurant actuellement à l'est du pays et sur laquelle se biseaute le Paléozoique. La sédimentation est marine, il s'agit d'une plate-forme carbonatée s'approfondissant au Carbonifère. De nombreuses évidences de diamectites et de figures de resédimentation ont été notées à partir de la fin du Dévonien. Le Trias marque la fin de ces dépôts et se caractérise par une érosion, sans doute due à une phase de rifting avortée. La sédimentation Jurassique et Crétacée est presque toujours continentale et souvent éolienne, il n'y a pas de structuration marquée. Au nord, dans la zone de Madidi, les dépôts du Crétacé terminal (Maestrichian montrent des intercalations marines riches en matière organique (Fm Flora, alors que son équivalent au centre et au Sud (Fm Cajones est purement gréseux. Le soulèvement de la cordillère orientale démarre à la fin de l'Oligocène (27 Ma, Sempere et al. , 1990 et le front de compression se déplace ensuite

  17. Comparison of Hemoglobin A1c assay performance on two different commercial systems

    Directory of Open Access Journals (Sweden)

    Jozo Ćorić

    2015-04-01

    Full Text Available Introduction: Glycated hemoglobin (HbA1c is formed by non-enzymatic binding of glucose to the free amino group of the N-terminal end of the ß-chain of hemoglobin A. HbA1c is representative of the mean blood glucose level over three months. The aim of the study was to evaluate the Hemoglobin A1c immunoturbidimetric assay performance on two different commercial systems.Methods: We evaluated the precision and trueness for determination of HbA1c in whole blood. Concentrations of total hemoglobin and HbA1c were evaluated on Dimension Xpand (Siemens and Cobas 501 (Roche analyzers. HbA1c was measured in a latex agglutination inhibition test. Commercial controls Liquichek Diabetes Control Level 1 and Liquichek Diabetes Control Level 2 (Bio Rad at two levels were used for quality control. Analytical validation of HbA1c included: within-run imprecision, between-day imprecision, inaccuracy and comparison determination on the human samples on 2 systems: Dimension Xpand and Cobas 501 analyzers. Results: Within-run imprecision on the commercially controls for Level 1 is 4.5% and Level 2 is 3.2% between-day imprecision on commercially controls is 6.1% Level 1 and 5.1% Level 2 for respectively inac- curacy on commercially controls for Level 1 is 1.8% and Level 2 is 4.8%. Method comparison on human samples shows the correlation coefficient of 0.99.Conclusion: The presented results of the analytical evaluation methods for the determination of HbA1c showed an acceptable accuracy and precision.

  18. Diagnosis of Neisseria gonorrhoeae Using Molecular Beacon

    Science.gov (United States)

    Patel, Achchhe Lal; Sonkar, Subash Chandra; Kumari, Indu; Saluja, Daman

    2015-01-01

    Neisseria gonorrhoeae is an important sexually transmitted diseases (STD) causing pathogen worldwide. Due to absence of an affordable diagnostic assay, routine screening of gonococcal infection becomes impossible in developing countries where infection rates are maximum. Treatment is given on the basis of symptoms alone which leads to spread of infection. Thus, development of a rapid, sensitive, specific, and PCR based visual diagnostic assay suitable for developing countries, required for better disease management, is aimed at in present study. Endocervical swabs were collected from patients visiting gynecology department of various hospitals in Delhi. In-house PCR based assay was developed and modified to visual assay using molecular beacon for end-point detection. It was evaluated against Roche AMPLICOR NG kit and rmp gene. Specificity of beacon was confirmed by competition experiments. Diagnostic test was 98.21% specific and 99.59% sensitive whereas negative and positive predicted value were 99.40% and 98.78%, respectively. We also observed that twice the concentration (2X) of premix was stable at 4°C for 4 months and dry swab samples gave concordant results with that of wet swabs. These features make the test best suitable for routine diagnosis of genital infections in developing countries. PMID:25802857

  19. [Clinical benefit of HCV core antigen assay in patients receiving interferon and ribavirin combination therapy].

    Science.gov (United States)

    Higashimoto, Makiko; Takahashi, Masahiko; Jokyu, Ritsuko; Saito, Hidetsugu

    2006-02-01

    A highly sensitive second generation HCV core antigen assay has recently been developed. We compared viral disappearance and kinetics data between commercially available core antigen assays, Lumipulse Ortho HCV Ag, and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor Test, Version 2 to estimate the predictive benefit of sustained viral response (SVR) and non-SVR in 59 patients treated with interferon and ribavirin combination therapy. We found a good correlation between HCV core Ag and HCV RNA level regardless of genotype. Although the sensitivity of the core antigen assay was lower than PCR, the dynamic range was broader than that of the PCR assay, so that we did not need to dilute the samples in 59 patients. We detected serial decline of core Ag levels in 24 hrs, 7 days and 14 days after interferon combination therapy. The decline of core antigen levels was significant in SVR patients compared to non-SVR as well as in genotype 2a, 2b patients compared to 1b. Core antigen-negative on day 1 could predict all 10 SVR patients (PPV = 100%), whereas RNA-negative could predict 22 SVR out of 25 on day 14 (PPV = 88.0%). None of the patients who had detectable serum core antigen on day 14 became SVR(NPV = 100%), although NPV was 91.2% on RNA negativity. An easy, simple, low cost new HCV core antigen detecting system seems to be useful for assessing and monitoring IFN treatment for HCV.

  20. Diagnostic accuracy of the ROCHE Septifast PCR system for the rapid detection of blood pathogens in neonatal sepsis-A prospective clinical trial.

    Science.gov (United States)

    Straub, Julia; Paula, Helga; Mayr, Michaela; Kasper, David; Assadian, Ojan; Berger, Angelika; Rittenschober-Böhm, Judith

    2017-01-01

    Diagnosis of neonatal sepsis remains a major challenge in neonatology. Most molecular-based methods are not customized for neonatal requirements. The aim of the present study was to assess the diagnostic accuracy of a modified multiplex PCR protocol for the detection of neonatal sepsis using small blood volumes. 212 episodes of suspected neonatal late onset sepsis were analyzed prospectively using the Roche SeptiFast® MGRADE PCR with a modified DNA extraction protocol and software-handling tool. Results were compared to blood culture, laboratory biomarkers and clinical signs of sepsis. Of 212 episodes, 85 (40.1%) were categorized as "not infected". Among these episodes, 1 was false positive by blood culture (1.2%) and 23 were false positive by PCR (27.1%). Of 51 (24.1%) episodes diagnosed as "culture proven sepsis", the same pathogen was detected by blood culture and PCR in 39 episodes (76.5%). In 8 episodes, more pathogens were detected by PCR compared to blood culture, and in 4 episodes the pathogen detected by blood culture was not found by PCR. One of these episodes was caused by Bacillus cereus, a pathogen not included in the PCR panel. In 76/212 (35.8%) episodes, clinical sepsis was diagnosed. Among these, PCR yielded positive results in 39.5% of episodes (30/76 episodes). For culture-positive sepsis, PCR showed a sensitivity of 90.2% (95%CI 86.2-94.2%) and a specificity of 72.9% (95%CI 67.0-79.0%). The Roche SeptiFast® MGRADE PCR using a modified DNA extraction protocol showed acceptable results for rapid detection of neonatal sepsis in addition to conventional blood culture. The benefit of rapid pathogen detection has to be balanced against the considerable risk of contamination, loss of information on antibiotic sensitivity pattern and increased costs.

  1. A propos du dernier livre de Sebastian Roché, Police de proximité, Nos politiques de sécurité, Paris, Seuil, 2005

    OpenAIRE

    Hassid, Olivier

    2006-01-01

    Les émeutes urbaines de novembre 2005 viennent de relancer le débat sur la nécessité de disposer d’une police de proximité. Mise en place par Jean-Pierre Chevènement et stoppée par Nicolas Sarkozy, la réforme de la police de proximité est, pour de nombreux observateurs, indispensable au maintien du pacte républicain. La sortie du livre de Sebastian Roché est, en ce sens, une aubaine pour le décideur public. L’objectif de ce livre est simple : éclairer celui-ci sur les causes de l’échec de cet...

  2. A propos du dernier livre de Sebastian Roché, Police de proximité, Nos politiques de sécurité, Paris, Seuil, 2005.

    OpenAIRE

    Hassid, Olivier

    2018-01-01

    Les émeutes urbaines de novembre 2005 viennent de relancer le débat sur la nécessité de disposer d’une police de proximité. Mise en place par Jean-Pierre Chevènement et stoppée par Nicolas Sarkozy, la réforme de la police de proximité est, pour de nombreux observateurs, indispensable au maintien du pacte républicain. La sortie du livre de Sebastian Roché est, en ce sens, une aubaine pour le décideur public. L’objectif de ce livre est simple : éclairer celui-ci sur les causes de l’échec de cet...

  3. Apports de l’archéobotanique à la compréhension de la Source des Roches, Chamalières (Puy-de-Dôme The archaeobotanic contribution to the understanding of la Source des Roches, Chamalières (Puy-de-Dôme

    Directory of Open Access Journals (Sweden)

    Béatrice Prat

    2008-04-01

    Full Text Available Au tout début de la période romaine, un taux d’arbres inhabituellement élevé a été mis en évidence par la palynologie sur le site de la Source des Roches à Chamalières (Puy-de-Dôme, gisement qui a livré plus de 3500 ex-voto en bois au début des années 70. Durant le second âge du Fer et l’époque romaine, un tel niveau de boisement n’est observé nulle part ailleurs, ni en plaine de Limagne, ni sur le plateau des Dômes. L’hypothèse d’un sanctuaire de plein air, soutenue par Anne-Marie Romeuf qui a dirigé la fouille, se trouve ainsi confortée par l’analyse pollinique, qui permet d’envisager la possibilité de la présence d’un « bois sacré » composé principalement de chênes. La combinaison des données archéobotaniques issues de la palynologie et de la carpologie contribue à renforcer la compréhension du site d’un point de vue paysager et nous renseigne également sur les types d’offrandes végétales associées au dépôt des ex-voto.Unusually high levels of tree pollen were revealed by palynology on the site of the Source des Roches in Chamalières (Puy-de-Dôme for the very beginning of the Roman period. The site had yielded more than 3500 wooden offerings in the early 70s. Such a high density of woodland can be found nowhere else for the Second Iron Age and the Roman period, neither in the plain of Limagne, nor on the plateau of Les Dômes. The hypothesis of an open air sanctuary, first advanced by Anne-Marie Romeuf, director of excavation, is therefore reinforced by the pollen analysis which leads us to consider the possibility that a “sacred grove” made up principally of oaks was present. The correlation of the archaeobotanic data from palynology and paleœthnobotany contributes to the strengthening of the site’s knowledge from the landscape’s point of view. We also have a better understanding of the vegetal offerings associated with the wooden statues.

  4. Vitamin B(12) Immunoassay on Roche Elecsys 2010: Effects of High Excess Concentration of Serum Vitamin B(12) in CKD Patients on Parenteral Administration.

    Science.gov (United States)

    Basu, Surupa; Chaudhuri, Subimal

    2011-10-01

    Vitamin B(12) being water soluble is excreted in the urine when administered in excess. The probability of finding an abnormally excess serum concentration would be almost surreal. We report a peculiar clinical situation that may impact the vitamin B(12) immunoassay on the Roche Elecsys 2010 due to excess analyte concentration. In separate episodes (Feb and June 2010), the Biochemistry laboratory of a tertiary-care hospital, Kolkata, India, encountered two critically ill patients with background chronic kidney disease (CKD), low urine output, and on cyanocoabalamin supplementation, who had serum vitamin B(12) concentrations far exceeding expected values; even post dialysis. The B(12) assays (pmol/l) were performed using electrochemiluminiscence immunoassay on Roche Elecsys 2010, the assay validity confirmed by concomitant quality control runs. The immunoassays failed to deliver results, flagged with "signal level below limit". Biotin therapy was ruled out as a possible interferent. In the first episode, re-assay of a repeat draw yielded same outcome; outsourcing on Immulite provided concentration of >738 pmol/l. Serial dilution gave result of >29520 pmol/l on Elecsys 2010. In the second, we gained from past experience. Vitamin B(12) concentration >59040 pmol/l was conveyed to the treating nephrologist the very day. The B(12) immunoassay on the Elecsys 2010 employs sequential incubation steps for competitive binding that is compromised in the event of abnormally excess B(12) concentration in patient sera akin to the prozone effect. This knowledge may be beneficial while assaying sera of CKD patients to avoid financial loss due unnecessary repeats and delay in turnaround time.

  5. Determination of Urine Albumin by New Simple High-Performance Liquid Chromatography Method.

    Science.gov (United States)

    Klapkova, Eva; Fortova, Magdalena; Prusa, Richard; Moravcova, Libuse; Kotaska, Karel

    2016-11-01

    A simple high-performance liquid chromatography (HPLC) method was developed for the determination of albumin in patients' urine samples without coeluting proteins and was compared with the immunoturbidimetric determination of albumin. Urine albumin is important biomarker in diabetic patients, but part of it is immuno-nonreactive. Albumin was determined by high-performance liquid chromatography (HPLC), UV detection at 280 nm, Zorbax 300SB-C3 column. Immunoturbidimetric analysis was performed using commercial kit on automatic biochemistry analyzer COBAS INTEGRA ® 400, Roche Diagnostics GmbH, Manheim, Germany. The HLPC method was fully validated. No significant interference with other proteins (transferrin, α-1-acid glycoprotein, α-1-antichymotrypsin, antitrypsin, hemopexin) was found. The results from 301 urine samples were compared with immunochemical determination. We found a statistically significant difference between these methods (P = 0.0001, Mann-Whitney test). New simple HPLC method was developed for the determination of urine albumin without coeluting proteins. Our data indicate that the HPLC method is highly specific and more sensitive than immunoturbidimetry. © 2016 Wiley Periodicals, Inc.

  6. Multicenter evaluation of an enzymatic method for glycated albumin.

    Science.gov (United States)

    Paleari, Renata; Bonetti, Graziella; Callà, Cinzia; Carta, Mariarosa; Ceriotti, Ferruccio; Di Gaetano, Nicola; Ferri, Marilisa; Guerra, Elena; Lavalle, Gabriella; Cascio, Claudia Lo; Martino, Francesca Gabriela; Montagnana, Martina; Moretti, Marco; Santini, Gabriele; Scribano, Donata; Testa, Roberto; Vero, Anna; Mosca, Andrea

    2017-06-01

    The use of glycated albumin (GA) has been proposed as an additional glycemic control marker particularly useful in intermediate-term monitoring and in situation when HbA 1c test is not reliable. We have performed the first multicenter evaluation of the analytical performance of the enzymatic method quantILab Glycated Albumin assay implemented on the most widely used clinical chemistry analyzers (i.e. Abbott Architect C8000, Beckman Coulter AU 480 and 680, Roche Cobas C6000, Siemens ADVIA 2400 and 2400 XPT). The repeatability of the GA measurement (expressed as CV, %) implemented in the participating centers ranged between 0.9% and 1.2%. The within-laboratory CVs ranged between 1.2% and 1.6%. A good alignment between laboratories was found, with correlation coefficients from 0.996 to 0.998. Linearity was confirmed in the range from 7.6 to 84.7%. The new enzymatic method for glycated albumin evaluated by our investigation is suitable for clinical use. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Self-collected cervicovaginal sampling for site-of-care primary HPV-based cervical cancer screening: a pilot study in a rural underserved Greek population.

    Science.gov (United States)

    Chatzistamatiou, Kimon; Chatzaki, Εkaterini; Constantinidis, Τheocharis; Nena, Evangelia; Tsertanidou, Athena; Agorastos, Theodoros

    2017-11-01

    In the present pilot study, the feasibility of a site-of-care cervicovaginal self-sampling methodology for HPV-based screening was tested in 346 women residing in underserved rural areas of Northern Greece. These women provided self-collected cervicovaginal sample along with a study questionnaire. Following molecular testing, using the cobas ® HPV Test, Roche ® , HPV positive women, were referred to colposcopy and upon abnormal findings, to biopsy and treatment. Participation rate was 100%. Regular pap-test examination was reported for 17.1%. Among hrHPV testing, 11.9% were positive and colposcopy/biopsy revealed 2 CIN3 cases. Non-compliance was the most prevalent reason for no previous attendance. Most women reported non-difficulty and non-discomfort in self-sampling (77.6% and 82.4%, respectively). They would choose self-sampling over clinician-sampling (86.2%), and should self-sampling being available, they would test themselves more regularly (92.3%). In conclusion, self-sampling is feasible and well-accepted for HPV-based screening, and could increase population coverage in underserved areas, helping towards successful prevention.

  8. Case report: When measured free T4 and free T3 may be misleading. Interference with free thyroid hormones measurements on Roche® and Siemens® platforms

    Directory of Open Access Journals (Sweden)

    Lewandowski Krzysztof C

    2012-10-01

    Full Text Available Abstract A 59-year old female patient presented with apathy and 6 kg weight gain. Investigations revealed severe primary hypothyroidism (TSH>100 μIU/ml. L-thyroxine (L-T4 was started and titrated up to 75 μg, once daily, with clinical improvement. Other investigations revealed very high titres of anti-thyroid peroxidase (anti-TPO and anti-thyroglobulin (anti-Tg antibodies. After three months, there was a fall in TSH to 12.74 μIU/ml, however, with unexpectedly high free T4 (FT4 - 6.8 ng/ml and free T3 (FT3 - 6.7 pg/ml concentrations [reference range (rr: 0.8-1.9 ng/ml and 1.5-4.1 pg/ml (Siemens®, respectively]. At this stage L-T4 was stopped, and this was followed by a rapid increase in TSH (to 77.76 μIU/ml and some decrease in FT4 and FT3, however FT4 concentration remained elevated (2.1 ng/ml. Following this, L-T4 was restarted. On admission to our Department, she was clinically euthyroid on L-T4, 88 μg, once daily. Investigations on Roche® platform confirmed mildly elevated TSH - 5.14 (rr: 0.27-4.2 μIU/ml with high FT4 [4.59 (rr: 0.93-1.7 ng/ml] and FT3 [4.98 (rr: 2.6-4.4 pg/ml] concentrations. Other tests revealed hypoechogenic ultrasound pattern typical for Hashimoto thyroiditis. There was no discrepancy in calculated TSH value following TSH dilution (101% recovery. Concentrations of FT4 and FT3 were assessed on the day of discontinuation of L-T4 and after four days by the means of Abbott® Architect I 1000SR platform. These revealed FT4 and FT3 concentrations within the reference range [e.g., FT4 - 1.08 ng/ml (rr: 0.7-1.48] vs 4.59 ng/ml (rr: 0.93-1.7, Roche®, FT3 - 3.70 pg/ml (rr: 1.71-3.71 vs 4.98 (rr: 2.6-4.4, Roche®], confirming assay interference. Concentrations of ferritin and SHBG were normal. Conclusions Clinicians must be aware of possible assay interference, including the measurements of FT4 and FT3 in the differential diagnosis of abnormal results of thyroid function tests that do not fit the patient clinical

  9. Treatment seeking behaviors related to gonorrhea among female sex workers in 7 cities in Indonesia

    Directory of Open Access Journals (Sweden)

    Roselinda Roselinda

    2014-02-01

    Full Text Available Abstrak Latar belakang:Gonore merupakan salah satu infeksi menular seksual yang menjadi permasalahan besar kesehatan terutama pada wanita penjaja seks (WPS di Indonesia. Tujuan dari artikel ini adalah untuk melihat hubungan antara pola pencarian pengobatan gonore. Metode:Data berasal dari studi potong lintang dengan responden WPS yang dipilih secara cluster random sampling dari 7 kota (Timika, Yogyakarta, Kupang, Samarinda, Pontianak, Makassar dan Tangerang di Indonesia pada tahun 2007. Diagnosis gonore berdasarkan hasil pemeriksaan Polymerase Chain Reaction (PCR menggunakan Amplicor CT/NG dari Roche yang telah disetujui oleh World Health Orgazation (WHO sebagai alat skrining gonore. Hasil:Proporsi responden yang menderita gonore sebesar 26.1% (404/1750. Persentase penderita gonore yang melakukan upaya pengobatan terdistribusi hampir sama dengan yang mengunjungi fasilitas kesehatan / dokter dengan yang membeli obat sendiri. Subyek yeng melakukan pengobatan tradisional memiliki risiko 44% lebih tinggi menderita gonore dibandingkan dengan subyek yang melakukan pengobatan di fasilitas kesehatan / dokter [risiko relatif suaian (RRa = 1,44; P = 0.044]. Sedangkan subyek yang tidak diobati dibandingkan dengan yang berobat ke fasilitas kesehatan / dokter lebih berisiko 55% menderita gonore (RRa = 1.55; P = 0.002.Kesimpulan: Wanita penjaja seks yang melakukan maupun yang tidak pengobatan tradisional dibandingkan dengan yang mengunjungi fasilitas kesehatan/dokter memiliki risiko yang lebih tinggi menderita gonore. (Health Science Indones 2013;2:87-92Kata kunci:gonore, wanita penjaja seks, IndonesiaAbstractBackground:Gonorrhea is one of sexually transmitted infections that have become a major health problem especially among female sex workers (FSW in Indonesia. The objective of this article is to identify the relationship between treatment seeking behaviors, the sites of study and gonorrhea among FSW. Methods: The data that analyzed derived from cross

  10. Developing Disease-Modifying Treatments in Alzheimer's Disease - A Perspective from Roche and Genentech.

    Science.gov (United States)

    Doody, R

    2017-01-01

    Alzheimer's disease (AD) is a chronic neurodegenerative disease for which no preventative or disease-modifying treatments currently exist. Pathological hallmarks include amyloid plaques and neurofibrillary tangles composed of hyper-phosphorylated tau protein. Evidence suggests that both pathologies are self-propagating once established. However, the lag time between neuropathological changes in the brain and the onset of even subtle clinical symptomatology means that patients are often diagnosed late when pathology, and neurodegeneration secondary to these changes, may have been established for several years. Complex pathological pathways associated with susceptibility to AD and changes that occur downstream of the neuropathologic process further contribute to the challenging endeavour of developing novel disease-modifying therapy. Recognising this complexity, effective management of AD must include reliable screening and early diagnosis in combination with effective therapeutic management of the pathological processes. Roche and Genentech are committed to addressing these unmet needs through developing a comprehensive portfolio of diagnostics and novel therapies. Beginning with the most scientifically supported targets, this approach includes two targeted amyloid-β monoclonal antibody therapies, crenezumab and gantenerumab, and an anti-tau monoclonal antibody, RO7105705, as well as a robust biomarker platform to aid in the early identification of people at risk or in the early stages of AD. Identification and implementation of diagnostic tools will support the enrolment of patients into clinical trials; furthermore, these tools should also support evaluation of the clinical efficacy and safety profile of the novel therapeutic agents tested in these trials. This review discusses the therapeutic agents currently under clinical development.

  11. Mechanical Properties of Rocks: Pore Pressure and Scale Effects Propriétés mécaniques des roches : pression de pore et effets d'échelle

    Directory of Open Access Journals (Sweden)

    Gueguen Y.

    2006-12-01

    Full Text Available Pore pressure plays a major role when considering rocks mechanical properties. In that field, the concept of effective pressure is a key one to deal with fluids mechanical effects. However, its frequent use has been the source of frequent confusing statements. Because of the various meanings which have been attached to that concept, an attempt is made in this paper to clarify it and examine the validity of its various uses relative to rock mechanical behaviour or rock properties. At a macroscopic scale, thermodynamics provides a powerful tool to investigate this. Reversible or irreversible thermodynamics provide general relationships of great interest. But because real rocks are non homogeneous systems, a microscopic approach is also required in order to analyze the mechanical properties from a description of the small scale processes. The microscopic approach is complementary of the macroscopic thermodynamic one as it leads to the calculation of the effective properties of the medium. In this last approach, effective medium theory is a powerful tool. The effective properties as derived from the microscale can be nicely combined to thermodynamic relations to interpret pore fluid pressure effects and scale effects. The example of elastic properties of porous rocks is more specifically emphasized to illustrate this because of both its intrinsic interest and importance as far as applications are concerned. La pression de pore joue un rôle de première importance dans la considération des propriétés mécaniques des roches. Dans ce domaine, le concept de contrainte effective est essentiel pour aborder les effets mécaniques. Toutefois, son utilisation fréquente a conduit à de nombreuses affirmations trompeuses. Compte tenu des significations diverses accordées à ce concept, nous tentons ici de le clarifier et examinons le domaine d'application de ses divers emplois dans le cadre du comportement mécanique ou des propriétés des roches. À l

  12. Screening tests for Chlamydia trachomatis or Neisseria gonorrhoeae using the cobas 4800 PCR system do not require a second test to confirm: an audit of patients issued with equivocal results at a sexual health clinic in the Northwest of England, U.K.

    Science.gov (United States)

    Hopkins, Mark J; Smith, Godfrey; Hart, Ian J; Alloba, Fath

    2012-11-01

    To assess the clinical utility of supplementary PCRs following a positive cobas 4800 CT/NG PCR screening test result. Laboratory reports, for Chlamydia trachomatis or Neisseria gonorrhoeae, issued to genitourinary medicine patients between April 2010 and April 2011 were reviewed retrospectively. Positive reports were routinely confirmed by supplementary PCRs and N gonorrhoeae culture. Clinical records of patients with unconfirmed positive (equivocal) reports were retrieved to determine if the infection was confirmed by a second sample obtained at patient recall and the impact of this process on antibiotic management. Over 15 000 patients were tested during the study period. The prevalence of chlamydia and gonorrhoea was 972 (5.75%) and 76 (0.50%), respectively. A further 78 chlamydia and 2 gonorrhoea equivocal reports were issued. Only 56 (72%) patients with an equivocal chlamydia report returned to the clinic, and of these, only 41 (73%) gave a second sample to retest. Positive predictive value (PPV) of the PCR screening test was calculated at 98.0% and 97.5% for detection of chlamydia infection from urine and rectal swabs, respectively. Most patients accepted antibiotic treatment before their infection status had been confirmed. Prevalence of gonorrhoea infection was low but the PPV of the screening PCR in urine specimens remained high (98.75%). Equivocal reports introduce delays to patient management, while the risk of unnecessary antibiotic therapy appears acceptable to most patients. The cobas 4800 CT/NG PCR screening assay can achieve UK testing standards (PPV >90%) for chlamydia, and low prevalence gonorrhoea in urine without supplementary tests. A patient-led confirmation algorithm is proposed.

  13. A study of the relationship between albuminuria, proteinuria and urinary reagent strips.

    LENUS (Irish Health Repository)

    Collier, Geraldine

    2012-02-01

    BACKGROUND: The aims of this study were to examine the relationship between proteinuria and albuminuria and to assess the equivalence between the albumin to creatinine ratio (ACR) and the protein to creatinine ratio (PCR) at the cut-offs recommended by the National Institute for Health and Clinical Excellence (NICE) guidance on chronic kidney disease. The sensitivity and specificity of the reagent strips used in our laboratory for the detection of clinical proteinuria was also assessed. METHODS: Urine samples (n = 117) were screened for protein using the Bayer Multistix 10SG and read manually. Urinary total protein and creatinine was measured on the Roche P Modular by the benzethonium chloride and kinetic Jaffe methods, respectively. Urinary albumin was measured by immunoturbidimetry on the Roche Cobas Mira. RESULTS: The relationship between urinary protein and albumin loss was non-linear (P < 0.05). As urinary protein loss increased the percentage of albumin to total protein increased. At the NICE guidance recommended cut-offs for clinical proteinuria (ACR > or =30 mg\\/mmol and PCR > or =50 mg\\/mmol) there was one discordant result between ACR and PCR (ACR <30 mg\\/mmol and PCR >50 mg\\/mmol). The Bayer Multistix 10SG had a sensitivity and specificity of 97% and 62%, respectively, for the detection of clinical proteinuria compared with ACR. CONCLUSIONS: The proportion of urinary total protein attributable to albumin changes with concentration. There was only one discordant result between ACR and PCR: therefore either ratio may be used for the identification of clinical proteinuria. As a screening test for proteinuria, the Bayer Multistix 10SG had an acceptable sensitivity but poor specificity.

  14. MODULAR ANALYTICS: A New Approach to Automation in the Clinical Laboratory.

    Science.gov (United States)

    Horowitz, Gary L; Zaman, Zahur; Blanckaert, Norbert J C; Chan, Daniel W; Dubois, Jeffrey A; Golaz, Olivier; Mensi, Noury; Keller, Franz; Stolz, Herbert; Klingler, Karl; Marocchi, Alessandro; Prencipe, Lorenzo; McLawhon, Ronald W; Nilsen, Olaug L; Oellerich, Michael; Luthe, Hilmar; Orsonneau, Jean-Luc; Richeux, Gérard; Recio, Fernando; Roldan, Esther; Rymo, Lars; Wicktorsson, Anne-Charlotte; Welch, Shirley L; Wieland, Heinrich; Grawitz, Andrea Busse; Mitsumaki, Hiroshi; McGovern, Margaret; Ng, Katherine; Stockmann, Wolfgang

    2005-01-01

    MODULAR ANALYTICS (Roche Diagnostics) (MODULAR ANALYTICS, Elecsys and Cobas Integra are trademarks of a member of the Roche Group) represents a new approach to automation for the clinical chemistry laboratory. It consists of a control unit, a core unit with a bidirectional multitrack rack transportation system, and three distinct kinds of analytical modules: an ISE module, a P800 module (44 photometric tests, throughput of up to 800 tests/h), and a D2400 module (16 photometric tests, throughput up to 2400 tests/h). MODULAR ANALYTICS allows customised configurations for various laboratory workloads. The performance and practicability of MODULAR ANALYTICS were evaluated in an international multicentre study at 16 sites. Studies included precision, accuracy, analytical range, carry-over, and workflow assessment. More than 700 000 results were obtained during the course of the study. Median between-day CVs were typically less than 3% for clinical chemistries and less than 6% for homogeneous immunoassays. Median recoveries for nearly all standardised reference materials were within 5% of assigned values. Method comparisons versus current existing routine instrumentation were clinically acceptable in all cases. During the workflow studies, the work from three to four single workstations was transferred to MODULAR ANALYTICS, which offered over 100 possible methods, with reduction in sample splitting, handling errors, and turnaround time. Typical sample processing time on MODULAR ANALYTICS was less than 30 minutes, an improvement from the current laboratory systems. By combining multiple analytic units in flexible ways, MODULAR ANALYTICS met diverse laboratory needs and offered improvement in workflow over current laboratory situations. It increased overall efficiency while maintaining (or improving) quality.

  15. Clinical value of IS6110-based loop-mediated isothermal amplification for detection of Mycobacterium tuberculosis complex in respiratory specimens.

    Science.gov (United States)

    Aryan, Ehsan; Makvandi, Manoochehr; Farajzadeh, Ahmad; Huygen, Kris; Alvandi, Amir-Hooshang; Gouya, Mohammad-Mehdi; Sadrizadeh, Ali; Romano, Marta

    2013-06-01

    A fundamental to global tuberculosis (TB) control is timely and accurate diagnosis of infectious cases of the disease. Among various methods, techniques based on nucleic acid amplification are the ones with promising prospects. The present study evaluates the diagnostic value of the recently developed IS6110-based loop-mediated isothermal amplification (LAMP) for detection of Mycobacterium tuberculosis complex (MTBC) in sputum specimens. In this cross-sectional study (2008-2009), IS6110-LAMP was evaluated on 101 sputum specimens from 93 highly suspected TB patients and compared to Amplicor MTB test and in-house IS6110-PCR and -nested PCR assays. Culture results or clinical recovery following anti-TB therapy was considered as a reference to prove the TB cases. The overall sensitivity of IS6110-LAMP, Amplicor, nPCR, and PCR were respectively 89.6% (69/77 specimens; 95% confidence interval [CI], 80.5-95.4%), 76.6% (59/77 specimens; CI, 65.6-85.5%), 79.2% (61/77 specimens; CI, 68.5-87.6%) and 59.7% (46/77 specimens; CI, 47.9-70.8%). The specificity and positive predictive value (PPV) were 100% for all the tests, and the negative predictive value (NPV) of IS6110-LAMP, Amplicor, nPCR, and PCR were respectively 75%, 57.1%, 60%, and 43.6%. There was an excellent overall agreement between LAMP and nPCR (k 0.828), and between LAMP and Amplicor (k 0.746), in addition to a better tolerance of IS6110-LAMP to inhibitors present in clinical specimens. The better diagnostic performance of IS6110-LAMP compared to Amplicor (p = 0.009), nPCR (p = 0.013) and PCR (p < 0.0001) besides its rapidity, simplicity, and cost-effectiveness makes it a valuable method for the detection of MTBC in clinical samples, particularly in resource-limited settings. Copyright © 2013 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  16. Therapy of chronic hepatitis C: Virologic response monitoring

    Directory of Open Access Journals (Sweden)

    Kuljić-Kapulica Nada

    2010-01-01

    Full Text Available Background/Aim. Virological testing is considered to be essential in the management of hepatitis C virus (HCV infection in order to diagnose infection, and, most importantly, as a quide for treatment decisions and assess the virological response to antiviral therapy. The aim of this study was to determine the rate of a sustained virological response (SVR and various factors associated with response rates in chronic hepatitis C infected patients treated with pegiinterferon alpha (PEGINF and ribavirin (RBV combination therapy. Methods. A total of 34 patients, treated with PEG-IFN and RBV were studied. Serum HCV-RNA was measured before the treatment, 12 weeks following the start of the therapy and 6 weeks after the treatment cessation. SVR was defined as undetectable serum HCV-RNA 6 months of post-treatment follow-up, virologic relapse (VR as relapse of HCV-RNA during the post-treatment follow-up. Serum HCV-RNA was measured with the Cobas Amplicor test. Results. At the end of post-treatment follow-up 19 (55.8% patients demonstrated a SVR. The majority of the patients were genotype 1 (27, and the other were genotype 3 (5 patients and genotype 4 (2 patients. There was VR in 6 patients 6 months after the therapy. In 9 patients HCV-RNA was positive after 12 weeks. Conclusion. We demonstrated that patients with chronic HCV infection can be successfully treated with combination of PEG-INF and RBV. This result emphasizes also that post-treatment follow-up to identify patients with SVR or VR could be important.

  17. [Genotyping of oncogenic human papilloma viruses in women with HG SIL diagnosis].

    Science.gov (United States)

    Kedzia, Witold; Pruski, Dominik; Józefiak, Agata; Rokita, Wojciech; Spaczyński, Marek

    2010-10-01

    Development of primary prevention of cervical cancer in other words a vaccination against selected, oncogenic HPV types, entails an increasing importance of epidemiological studies and prevalence of various types of human papilloma virus. The incidence of HPV varies depending on the geographic location of the population. The effectiveness of primary prevention against HPV 16, 18, in the context of reducing the incidence of cervical cancer will depend, among others, on the prevalence of these types in the population and virus-like antigens, which are partially cross-resistant. Identification of the most frequent, oncogenic HPV types in women with HG SIL diagnosis from Central and Western Poland to assess the merits of the development of primary prevention. For the purpose of molecular tests identifying the presence of 13 DNA oncogenic virus types, swabs were taken with the cyto-brush from 76 women diagnosed with CIN 2 or CIN 3 (HG SIL). Patients eligible for the study were diagnosed at the Laboratory of Pathophysiology of Uterine Cervix, Gynecology and Obstetrics Clinical Hospital of Karol Marcinkowski University of Medical Sciences. Patients came from Central and Western parts of Poland. Cell material in which the method of Amplicor HPV (Roche Diagnostics) identified the presence of DNA of oncogenic HPV types was in each case subsequently subjected to genotyping using the molecular test - Linear Array HPV Genotyping (Roche Diagnostics). Five most common oncogenic HPV types in order of detection included: 16, 33, 18, 31, 56. Together these five types of virus comprised 75.86% (88/116) of all detected HPV types. 1. In women from Central and Western Poland, diagnosed with HG SIL, the most common HPV genotypes were HPV 16, HPV33, HPV 18, HPV31, HPV56. 2. Two HPV types 16 and 18, against which vaccinations are directed, belong to the group of three genotypes of HPV most commonly identified in the evolution of CIN 2, CIN 3 diagnosed in women from Central and Western

  18. Treatment response in HCV related chronic hepatitis

    International Nuclear Information System (INIS)

    Hussain, A.B.; Hussain, T.; Hussain, S.; Masood, A.; Kazmi, Y.; Tariq, W.Z.; Karamat, K.A.

    2004-01-01

    Objective: To evaluate the virological response to treatment with interferon and ribavirin in-patients with hepatitis C related liver disease. Material and Methods: Two hundred seventy-nine patients were included in the study. These patients had taken interferon and ribavirin treatment for HCV related chronic hepatitis, and were referred to AFIP for HCV RNA testing by polymerase chain reaction (PCR) between January 2002 and September 2002. Out of 279 cases, 229 had taken the treatment for 06 or 12 months and were tested for end-of-treatment response (ETR). Fifty patients had completed there treatment regimens of 6 or 12 months treatment, at least 24 weeks before their PCR test and were having follow-up testing for sustained viral response (SVR). The sera of these patients were tested for HCV RNA by PCR, using a commercial kit of Amplicor (Roche) for qualitative detection of HCV RNA. Results: Out of 229 cases tested for end-of-treatment response, 198 (86.5%) had no detectable HCV RNA (responders) and 31 (13.50%) were PCR positive (non-responders). Thirty-eight out of 50 cases, tested for a sustained viral response, had a negative result for HCV PCR thus showing sustained response rate of 76%. Conclusion: The viral remission/response to interferon and ribavirin combination therapy in our patients was better than that quoted in other regions. (author)

  19. Comparison of the Hologic Aptima HIV-1 Quant Dx Assay to the Roche COBAS Ampliprep/COBAS TaqMan HIV-1 Test v2.0 for the quantification of HIV-1 RNA in plasma samples

    DEFF Research Database (Denmark)

    Schønning, Kristian; Johansen, Kim; Landt, Bodil

    2017-01-01

    load compared to the CAPCTMv2 was observed in Bland-Altman analysis, by Deming regression (Slope 1.13) and in dilution series of clinical samples. Precision evaluated using the Acrometrix Positive Controls was similar for the High Control (CV: 1.2% vs. 1.3%; Aptima assay vs. CAPCTMv2 test, respectively...

  20. Gamma-emissions of some meteorites and terrestrial rocks. Evaluation of lunar soil radioactivity; Emissions gamma de quelques meteorites et roches terrestres. Evaluation de la radioactivite du sol lunaire

    Energy Technology Data Exchange (ETDEWEB)

    Nordemann, D. [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1966-07-01

    The gamma-emissions of some terrestrial rocks and of the following meteorites: Bogou, Eagle-Station, Granes, and Dosso were studied by quantitative low background gamma spectrometry. These measurements and their interpretation lead to the evaluation of the possible gamma-emissions of several models of lunar soils. (author) [French] Les emissions gamma des meteorites Bogou, Eagle-Station, Granes et Dosso et de quelques roches terrestres ont ete etudiees par spectrometrie gamma quantitative a faible mouvement propre. Ces mesures et leur interpretation permettent d'evaluer les principales contributions des emissions gamma du sol lunaire pour des modeles de compositions possibles variees. (auteur)

  1. Gamma-emissions of some meteorites and terrestrial rocks. Evaluation of lunar soil radioactivity; Emissions gamma de quelques meteorites et roches terrestres. Evaluation de la radioactivite du sol lunaire

    Energy Technology Data Exchange (ETDEWEB)

    Nordemann, D [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1966-07-01

    The gamma-emissions of some terrestrial rocks and of the following meteorites: Bogou, Eagle-Station, Granes, and Dosso were studied by quantitative low background gamma spectrometry. These measurements and their interpretation lead to the evaluation of the possible gamma-emissions of several models of lunar soils. (author) [French] Les emissions gamma des meteorites Bogou, Eagle-Station, Granes et Dosso et de quelques roches terrestres ont ete etudiees par spectrometrie gamma quantitative a faible mouvement propre. Ces mesures et leur interpretation permettent d'evaluer les principales contributions des emissions gamma du sol lunaire pour des modeles de compositions possibles variees. (auteur)

  2. Diagnostic effectiveness of immunoassays systems for hepatitis C virus in samples from multi-transfusion patients

    International Nuclear Information System (INIS)

    Rivero Jimenez, Rene A; Merlin Linares, Julio C; Blanco de Armas, Madelin; Navea Leyva, Leonor M

    2009-01-01

    Hepatitis C virus (CHV) blood-transmission is a health problem in Cuba and in the world. Some types of diagnostic immunoassays have been developed for the blood certification and in general have a high diagnostic sensitivity and specificity in healthy donors. However, its behavior in samples from multi-transfusion patients could by less effective. To assess the diagnostic effectiveness of the UMELISA HCV third generation Cuban immunoassay (TecnoSUMA, S.A. La Habana), Cuba) in samples from multi-transfusion patients, in parallel, 335 sera from patients were processed by UBI HCV EIA 4.0 (United Biomedical, EE.UU) and UMELISA HCV third generation, and the samples with incongruous results were verified by PCR COBAS AmpliScreen HCV Test, v2 system (Roche, EE.UU.) Comparing the UMELISA HCV third generation system with the UBI HCV EIA 4.0 it was achieved a Sd of 95,8% CI(95%): 92,5-99,15 and a Ed of 100% CI (95%): 99,7-100, with IY: 0,96 (0,93-0,99) with k: 0,0582 ID (95%): 0,9276-0,9888, p = 0,000. Both immunoassay systems were satisfactory for immunodiagnosis of multi-transfusion patients

  3. Fecal electrolyte testing for evaluation of unexplained diarrhea: Validation of body fluid test accuracy in the absence of a reference method.

    Science.gov (United States)

    Voskoboev, Nikolay V; Cambern, Sarah J; Hanley, Matthew M; Giesen, Callen D; Schilling, Jason J; Jannetto, Paul J; Lieske, John C; Block, Darci R

    2015-11-01

    Validation of tests performed on body fluids other than blood or urine can be challenging due to the lack of a reference method to confirm accuracy. The aim of this study was to evaluate alternate assessments of accuracy that laboratories can rely on to validate body fluid tests in the absence of a reference method using the example of sodium (Na(+)), potassium (K(+)), and magnesium (Mg(2+)) testing in stool fluid. Validations of fecal Na(+), K(+), and Mg(2+) were performed on the Roche cobas 6000 c501 (Roche Diagnostics) using residual stool specimens submitted for clinical testing. Spiked recovery, mixing studies, and serial dilutions were performed and % recovery of each analyte was calculated to assess accuracy. Results were confirmed by comparison to a reference method (ICP-OES, PerkinElmer). Mean recoveries for fecal electrolytes were Na(+) upon spiking=92%, mixing=104%, and dilution=105%; K(+) upon spiking=94%, mixing=96%, and dilution=100%; and Mg(2+) upon spiking=93%, mixing=98%, and dilution=100%. When autoanalyzer results were compared to reference ICP-OES results, Na(+) had a slope=0.94, intercept=4.1, and R(2)=0.99; K(+) had a slope=0.99, intercept=0.7, and R(2)=0.99; and Mg(2+) had a slope=0.91, intercept=-4.6, and R(2)=0.91. Calculated osmotic gap using both methods were highly correlated with slope=0.95, intercept=4.5, and R(2)=0.97. Acid pretreatment increased magnesium recovery from a subset of clinical specimens. A combination of mixing, spiking, and dilution recovery experiments are an acceptable surrogate for assessing accuracy in body fluid validations in the absence of a reference method. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Associated liver enzymes with hyperlipidemic profile in type 2 diabetes patients.

    Science.gov (United States)

    Al-Jameil, Noura; Khan, Farah A; Arjumand, Sadia; Khan, Mohammad F; Tabassum, Hajera

    2014-01-01

    Type 2 diabetes mellitus (T2DM) is characterized by hyperglycemia and is associated with dyslipidemia and disturbed liver function. Aim of the present work is to assess the liver enzymes and to find its association with hyperlipidemic profile in T2DM. Total of 157 subjects were studied and divided into two groups; diabetes (n=81) and non-diabetes (n=76). Various biochemical parameters like fasting glucose, post prandial glucose, HbA1c, total cholesterol (TC), triglycerides (Tg), high density lipoprotein cholesterol (HDL-C), alanine amino transferase (ALT), aspartate amino transferase (AST) and gamma-glutamyl transferase (GGT) were analyzed by ROCHE module Cobas 6000 (C501 & C601) analyzer, kits were procured by ROCHE diagnostics. Low density lipoprotein cholesterol (LDL-C) was estimated by Freidwald's formula. Statistical analysis was performed by applying student t test and Pearson's correlation coefficient, at 0.0001 and 0.05 level of significance, respectively. All the glycemic control parameters, lipid profile parameters except HDL-C and liver enzymes were found increased in diabetes group and significantly differ from non-diabetes group (p>0.0001). ALT showed significant positive correlation with fasting glucose, post prandial glucose, HbA1c, TC, Tg, LDL-C and GGT at p>0.05. AST showed very weak relation with all parameters while GGT was positively associated with fasting glucose, post prandial glucose, HbA1c, TC, Tg, LDL-C and ALT at p>0.05. In conclusion, T2DM incline to elevate liver enzymes, especially ALT and GGT were of significance. Routine screening of ALT and GGT in T2DM patients may assists early detection of liver abnormalities and to arrest the progress of disease.

  5. Performance of strip-based glucose meters and cassette-based blood gas analyzer for monitoring glucose levels in a surgical intensive care setting.

    Science.gov (United States)

    Claerhout, Helena; De Prins, Martine; Mesotten, Dieter; Van den Berghe, Greet; Mathieu, Chantal; Van Eldere, Johan; Vanstapel, Florent

    2016-01-01

    We verified the analytical performance of strip-based handheld glucose meters (GM) for prescription use, in a comparative split-sample protocol using blood gas samples from a surgical intensive care unit (ICU). Freestyle Precision Pro (Abbott), StatStrip Connectivity Meter (Nova), ACCU-CHEK Inform II (Roche) were evaluated for recovery/linearity, imprecision/repeatability. The GMs and the ABL90 (Radiometer) blood gas analyzer (BGA) were tested for relative accuracy vs. the comparator hexokinase glucose-6-phosphate-dehydrogenase (HK/G6PDH) assay on a Cobas c702 analyzer (Roche). Recovery of spiked glucose was linear up to 19.3 mmol/L (347 mg/dL) with a slope of 0.91-0.94 for all GMs. Repeatability estimated by pooling duplicate measurements on samples below (n=9), in (n=51) or above (n=80) the 4.2-5.9 mM (74-106 mg/dL) range were for Freestyle Precision Pro: 4.2%, 4.0%, 3.6%; StatStrip Connectivity Meter: 4.0%, 4.3%, 4.5%; and ACCU-CHEK Inform II: 1.4%, 2.5%, 3.5%. GMs were in agreement with the comparator method. The BGA outperformed the GMs, with a MARD of 3.9% compared to 6.5%, 5.8% and 4.4% for the FreeStyle, StatStrip and ACCU-CHEK, respectively. Zero % of the BGA results deviated more than the FDA 10% criterion as compared to 9.4%, 3.7% and 2.2% for the FreeStyle, StatStrip and ACCU-CHEK, respectively. For all GMs, icodextrin did not interfere. Variation in the putative influence factors hematocrit and O2 tension could not explain observed differences with the comparator method. GMs quantified blood glucose in whole blood at about the 10% total error criterion, proposed by the FDA for prescription use.

  6. PARTICULAR OF THE BONE METABOLISM IN CHILDREN WITH THE EXTREMITIES’ FRACTURES

    Directory of Open Access Journals (Sweden)

    T. A. Galiatina

    2013-01-01

    Full Text Available 35 children with extremities’ long bones fractures of the different localization were examined. The medium age (10.5 ± 2.0 years. The control group consisted of 35 healthy children: without pathology of the supporting-motor apparatus, medium age 10.5 ± 3.0. The single study of the systemic and ionized calci-um, phosphorus, magnesium and alkaline concentration and phosphatase’s activity in the blood serum was realized using automatic analyzers «Cobas 6000 SWA» (Roche Diagnostics, Switzerland.The forming and bone resorption process activity was appreciated according to the P1NP (N-terminal propeptide of type I collagen content in the blood serum, osteocalcin аnd β-СrossLaps (β-isomerized carboxy-terminal cross-linking region of type I collagen on the modular platform «Cobas 6000 SWA» (Roche Diagnostics,Switzerland. The mineral turnover’s regulation was determined by parathyroid hor-mone, thyrocalcitonin and 25(ОН-D3 in the blood serum. The growth process activity was determined by content of the somatotropic hormone in the blood serum. Osteocalcin and somatotropic hormone de-termination was done by analyzer «Immulite One» (USА.The statistical processing of the obtained results was carried out with application program package Statistica 6.0 for Windows. The distribution normalcy control was performed using the Kolmogorov-Smirnov's test. Data were presented as Ме (LQ–UQ, where Ме is median, (LQ–UQ is interquartile dis-persion. To reveal the differences between groups concerning quantitative readings the Mann–Whitney and Craskell–Wallace tests were used. The disparities were counted as statistically significant in р < 0.05. The correlation analysis was carried out by means of Spearman criterion.Children with extremities’ long bones fractures demonstrated the decrease of the bony tissue synthesis markers P1NP and calcium ions in the blood serum that speaks for the relative predominance of the resorptive activity of

  7. Estimation of the rate of mother to child transmission of HIV in Nigeria.

    Science.gov (United States)

    Audu, R A; Salu, O B; Musa, A Z; Onyewuche, J; Funso-Adebayo, E O; Iroha, E O; Ezeaka, V C; Adetifa, I M O; Okoeguale, B; Idigbe, E O

    2006-06-01

    Definitive diagnosis of HIV infection in infants mothers is still posing some difficulty in Nigeria and other developing countries. Within this age definitive diagnosis can only be carried out by antigen based techniques which are indeed not available in these developing countries. This has resulted in the absence of authoritative data on the rate of mother-to-child transmission in these countries. Nigeria inclusive. The present pilot study was therefore carried out to generate some information on the rate of mother to child transmission in Nigeria using the PCR technique. Plasma samples were obtained from 68 children of both sexes less than 18 months of age and who were born to HIV infected mothers. The samples were collected from two pediatric departments. in Lagos and in Benin. The presence of HIV 1 RNA in each of the samples. was determined using the Amplicor Monitor V 1.5 technique (Roche Diagnostics). Data showed that HIV-1 RNA was detected in 15 of the 68 samples tested. This gave an HIV-1 RNA detection rate of 22%. Among women who had some intervention, the rate of transmission of infection was 11% while the rate among those without intervention was 30%. The 22% transmission rate recorded in this study is close to the range of 25 to 35% that has been reported in several developed and a few developing countries. A multicenter nationwide study will still be needed to determine the national mother to child transmission rate in Nigeria.

  8. PENGEMBANGAN MODEL KOLABORASI JIGSAW ROLE PLAYING SEBAGAI UPAYA PENINGKATAN KEMAMPUAN BEKERJASAMA SISWA KELAS V SD PADA PELAJARAN IPS

    Directory of Open Access Journals (Sweden)

    Ika Ari Pratiwi

    2015-11-01

    Full Text Available Penelitian bertujuan untuk mengembangkan model kolaborasi jigsaw, role playing untuk meningkatkan kemampuan bekerjasama siswa yang valid, efektif dan praktis. Metode penelitian adalah penelitian dan pengembangan (R&D. Tahap uji coba pengembangan terdiri atas uji coba ahli, uji coba skala terbatas dan uji coba skala luas. Keefektifan model kolaborasi jigsaw role playing  diperoleh rata-rata 51,83 dalam kategori baik diterapkan dalam pelajaran IPS, peningkatan kemampuan bekerjasama siswa hasil N-gain = 0,56 dengan kategori sedang, peningkatan hasil belajar IPS N-gain = 0,50 dengan kategori sedang dan hasil ketuntasan klasikal pembelajaran IPS 97,14%.  Hasil respon guru dan siswa terhadap model yang digunakan adalah berkriteria baik. Model final penelitian ini menghasilkan model kolaborasi jigsaw role playing yang dikemas dalam suatu buku pedoman.

  9. Comparison of Abbott AxSYM and Roche Elecsys 2010 for measurement of BNP and NT-proBNP.

    Science.gov (United States)

    Chien, Tzu-I; Chen, Hui-Hou; Kao, Jau-Tsuen

    2006-07-15

    B-type natriuretic peptide (BNP) and N-terminal pro-brain natriuretic peptide (NT-proBNP) are small cardiac hormones released from the heart. They can be used as an important aid to diagnose congestive heart failure (CHF). We compared the performances of the Abbott AxSYM and Roche Elecsys 2010 for the measurement of BNP and NT-proBNP. The first method uses a microparticle enzyme-linked immunoassay, whereas the other uses chemiluminescent immunometric assay. The CVs using pooled sera ranged from 3.7% to 12.7% for the AxSYM and 0.9% to 2.2% for the Elecsys 2010. The Passing and Bablok regression was Elecsys 2010 NT-proBNP=7.23xAxSYM BNP+2.53. The BNP in EDTA plasma was more stable than in serum. The immunoreactivity difference of NT-proBNP in serum or EDTA plasma was within 10% when stored at 4 degrees Celsius or 25 degrees Celsius for 72 h. Receiver operating characteristic (ROC) curves were different for both assays, and the areas under the curves were 0.704 and 0.841 for the AxSYM and Elecsys 2010 method, respectively. Both assays were not entirely specific for heart failure. The precision and stability for NT-proBNP was better than for BNP in serum. It is important to use method-appropriate reference ranges (or cutoff) for the BNP and NT-proBNP, respectively, in the assessment of CHF.

  10. Analyse géochimique de la matiére organique extraite des roches sédimentaires. IV. Extraction des roches en faible quantités Geochemical Analysis of Organic Matter Extracted from Sedimentary Rocks Iv. Exraction from Small Amounts of Rock

    Directory of Open Access Journals (Sweden)

    Monin J. C.

    2006-11-01

    Full Text Available L'extraction en Soxhlet est inappllcable lorsque les échantillons de roche sont de trop petite taille. A l'occasion de la mise au point du protocole d'extraction correspondant, on examine l'influence d'un certain nombre de conditions opératoires sur le rendement d'extraction : température, durée nature et quantité du solvant, présence de lumière, présence d'air, procédé d'extraction. Pour les hydrocarbures, tant saturés qu'aromatiques, le facteur essentiel est l'agitation du milieu d'extraction ; la nature du solvant n'est pas critique, à condition de ne pas choisir un très mauvais solvant des hydrocarbures : l'extractibilité est en effet plus fonction du pouvoir désorbant vis-à-vis de la roche que du pouvoir solvant proprement dit. Pour les résines et asphalténes, l'interprétation des résultats est délicate, car la frontière n'est pas nette entre produits simplement dissous, produits de solvolyse et, produits de néoformation par interaction solvant-matière organique-matière minérale. II n'existe donc pas de protocole d'extraction recommandable dans l'absolu. Tout dépend des exigences analytiques et aussi pratiques du laboratoire; à l'Institut Français du Pétrole (IFP le protocole retenu est l'extraction en bécher avec agitation magnétique pendant 20 min dans le chroroforme à 50 °C (approximativement; on donne aussi le protocole d'évaporation du solvant et de récupération de l'extrait, qui doit être étudié soigneusement étant donné les faibles quantités mises en jeu. A Soxhlet extractor cannot be used with rock samples that are too small in size. With the development of on extraction procédure for such cases, this article examines the influence of various operating conditions on extraction yield, i. e. temperature, duration, nature and amount of solvent, presence of light, présence of air and extraction process. For both saturated and aromatic hydrocarbons, the essential factor is the stirring of the

  11. Chlamydia trachomatis infection and associated risk factors in a low-income marginalized urban population in coastal Peru Infección por Chlamydia trachomatis y factores de riesgo asociados en una población marginal urbana de bajos ingresos de la costa peruana

    Directory of Open Access Journals (Sweden)

    Segundo R. León

    2009-07-01

    Full Text Available OBJECTIVES: To estimate Chlamydia trachomatis (CT infection prevalence and associated risk factors among a low-income marginalized urban population in Peru. METHODS: Between April 2003 and April 2005, men and women at high-risk for sexually transmitted infections (STIs were recruited from low-income urban areas in three coastal cities in Peru (Chiclayo, Lima, and Trujillo. Consenting participants were studied using a sero-epidemiologic survey. Urine and vaginal swabs collected from men and women were evaluated using polymerase chain reaction (PCR (COBAS® AMPLICOR (CT/NG Test, Roche Molecular Diagnostics, Branchburg, NJ, USA for CT. RESULTS: Among the 2 440 participants recruited for the study (2 145 men and 295 women, overall prevalence of CT infection was 6.6% (95% CI, 5.6-7.6%: 5.5% (95% CI, 4.5-6.5% in men and 14.9% (95% CI, 11.7-27.1% in women. Chlamydial infection was inversely associated with age and positively associated with HIV infection and dysuria in men. Among women, chlamydial infection was inversely associated with age and positively associated with number of sex partners. CONCLUSIONS: CT infection was common among high-risk men and women in urban coastal Peru. Because chlamydial infection is associated with complications related to female reproduction, including infertility and ectopic pregnancy, interventions to prevent and treat infection and studies to determine the feasibility of population-based screening for CT should be conducted among the high-risk female population.OBJETIVOS: Estimar la prevalencia de la infección por Chlamydia trachomatis y los factores de riesgo asociados en una población marginal urbana de bajos ingresos de Perú. MÉTODOS: Entre abril de 2003 y abril de 2005 se captaron hombres y mujeres con alto riesgo de contraer infecciones de transmisión sexual, en áreas urbanas de bajos ingresos de tres ciudades costeras de Perú (Chiclayo, Lima y Trujillo. Los participantes que aceptaron colaborar

  12. Diffusion Properties of Carbonated Caprocks from the Paris Basin Propriétés diffusives de roches de couverture carbonatées du Bassin de Paris

    Directory of Open Access Journals (Sweden)

    Berne P.

    2009-11-01

    carbonated caprocks (regardless of the problem of alteration by acidified water, not addressed here. Lastly, a few simple rules for extending the results presented here to other experimental conditions are proposed. L’efficacite d’un stockage geologique de CO2 repose sur les proprietes de confinement des roches de couverture. Parmi ces proprietes, les caracteristiques diffusives jouent un role important qui est parfois sous-estime. En effet, la diffusion est un processus lent mais qui peut s’averer non negligeable sur le long terme. De plus, les caracteristiques recherchees pour une roche de couverture, principalement une forte pression d’entree et une faible permeabilite, ne sont pas incompatibles avec des coefficients de diffusion relativement eleves, puisque ces grandeurs sont liees a des caracteristiques geometriques differentes (schematiquement, les tailles de pore pour les unes et la tortuosite pour les autres. Dans le cadre du projet Geocarbone–INTEGRITE, finance par l’ANR de 2006 a 2008, on a donc mesure les coefficients de diffusion de l’eau et de l’ion bicarbonate dans des echantillons de roche de couvertures carbonatees provenant de trois niveaux (formations des Calcaires du Comblanchien et de la Dalle Nacree. Ces deux especes permettent en effet de couvrir, en premiere approximation, les situations rencontrees en conditions de stockage (espece neutre/espece chargee, interagissant ou non avec la matrice solide. Dans un premier temps, on presente le modele simple de diffusion utilise pour le depouillement des experiences, ce qui permet de passer en revue les differentes grandeurs utiles : coefficient de diffusion effectif, coefficient de diffusion de pore, coefficient de diffusion apparent, porosite accessible, facteur de retard. Le coefficient d’autodiffusion de l’eau est mesure par deux techniques differentes (Resonance Magnetique Nucleaire et tracage radioactif a l’eau tritiee 1H3HO dans deux echantillons. Les resultats obtenus sont

  13. Assessment of the Roche Linear Array HPV Genotyping Test within the VALGENT framework.

    Science.gov (United States)

    Xu, Lan; Oštrbenk, Anja; Poljak, Mario; Arbyn, Marc

    2018-01-01

    Cervical cancer screening programs are switching from cytology-based screening to high-risk (hr) HPV testing. Only clinically validated tests should be used in clinical practice. To assess the clinical performance of the Roche Linear Array HPV genotyping test (Linear Array) within the VALGENT-3 framework. The VALGENT framework is designed for comprehensive comparison and clinical validation of HPV tests that have limited to extended genotyping capacity. The Linear Array enables type-specific detection of 37 HPV types. For the purpose of this study, Linear Array results were designated as positive only if one of the 13 hrHPV types also included in the Hybrid Capture 2 (HC2) was detected. The VALGENT-3 framework comprised 1600 samples obtained from Slovenian women (1300 sequential cases from routine cervical cancer screening enriched with 300 cytological abnormal samples). Sensitivity for cervical intraepithelial neoplasia of grade 2 or worse (CIN2+) (n=127) and specificity for Linear Array and for HC2 and non-inferiority of Linear Array relative to HC2 was checked. In addition, the prevalence of separate hrHPV types in the screening population, as well as the concordance for presence of HPV16, HPV18 and other hrHPV types between Linear Array and the Abbott RealTime High Risk HPV test (RealTime) were assessed. The clinical sensitivity and specificity for CIN2+ of the Linear Array in the total study population was 97.6% (95% CI, 93.3-99.5%) and 91.7% (95% CI, 90.0-93.2%), respectively. The relative sensitivity and specificity of Linear Array vs HC2 was 1.02 [95% CI, 0.98-1.05, (pLinear Array in the screening population was 10.5% (95% CI, 8.9-12.3%) with HPV16 and HPV18 detected in 2.3% and 0.9% of the samples, respectively. Excellent agreement for presence or absence of HPV16, HPV18 and other hrHPV between Linear Array and RealTime was observed. Linear Array showed similar sensitivity with higher specificity to detect CIN2+ compared to HC2. Detection of 13 hrHPV types

  14. Assessment of real-time PCR method for detection of EGFR mutation using both supernatant and cell pellet of malignant pleural effusion samples from non-small-cell lung cancer patients.

    Science.gov (United States)

    Shin, Saeam; Kim, Juwon; Kim, Yoonjung; Cho, Sun-Mi; Lee, Kyung-A

    2017-10-26

    EGFR mutation is an emerging biomarker for treatment selection in non-small-cell lung cancer (NSCLC) patients. However, optimal mutation detection is hindered by complications associated with the biopsy procedure, tumor heterogeneity and limited sensitivity of test methodology. In this study, we evaluated the diagnostic utility of real-time PCR using malignant pleural effusion samples. A total of 77 pleural fluid samples from 77 NSCLC patients were tested using the cobas EGFR mutation test (Roche Molecular Systems). Pleural fluid was centrifuged, and separated cell pellets and supernatants were tested in parallel. Results were compared with Sanger sequencing and/or peptide nucleic acid (PNA)-mediated PCR clamping of matched tumor tissue or pleural fluid samples. All samples showed valid real-time PCR results in one or more DNA samples extracted from cell pellets and supernatants. Compared with other molecular methods, the sensitivity of real-time PCR method was 100%. Concordance rate of real-time PCR and Sanger sequencing plus PNA-mediated PCR clamping was 98.7%. We have confirmed that real-time PCR using pleural fluid had a high concordance rate compared to conventional methods, with no failed samples. Our data demonstrated that the parallel real-time PCR testing using supernatant and cell pellet could offer reliable and robust surrogate strategy when tissue is not available.

  15. Effects of different centrifugation conditions on clinical chemistry and Immunology test results

    Directory of Open Access Journals (Sweden)

    Nesic Predrag

    2011-05-01

    Full Text Available Abstract Background The effect of centrifugation time of heparinized blood samples on clinical chemistry and immunology results has rarely been studied. WHO guideline proposed a 15 min centrifugation time without citing any scientific publications. The centrifugation time has a considerable impact on the turn-around-time. Methods We investigated 74 parameters in samples from 44 patients on a Roche Cobas 6000 system, to see whether there was a statistical significant difference in the test results among specimens centrifuged at 2180 g for 15 min, at 2180 g for 10 min or at 1870 g for 7 min, respectively. Two tubes with different plasma separators (both Greiner Bio-One were used for each centrifugation condition. Statistical comparisons were made by Deming fit. Results Tubes with different separators showed identical results in all parameters. Likewise, excellent correlations were found among tubes to which different centrifugation conditions were applied. Fifty percent of the slopes lay between 0.99 and 1.01. Only 3.6 percent of the statistical tests results fell outside the significance level of p Conclusion A centrifugation time of either 7 or 10 min provided identical test results compared to the time of 15 min as proposed by WHO under the conditions used in our study.

  16. Diagnosis and Follow Up of Prostate Carcinoma by an in House Prostate Specific Antigen ELISA Kit at Pramongkutklao Hospital

    International Nuclear Information System (INIS)

    Dumrongpisutikut, S.; Raungdilokrut, S.

    1998-01-01

    PSA ELISA kit was developed and compared to a commercial PSA ELISA kit (Cobas Registered trade mark Core PSA EIA, Roche Switzerland) with a correlation of 98.9% (r 0.989, p < 0.05). The precision of the assay kit evaluated by intermal quality control studies shown that the coefficient of variation of high, medium and low control were 4.4, 3.6 and 4.7% respectively. The sentuvity of detection was 0.25 ng/ml. This PSA ELISA kit has been used for detection of PSA in serum of 571 patients ages between 25-93 years old with satisfactory results. The normal range of PSA is 0 - 3.46 ng/ml (X-bar = 2SD, n = 384). The mean value of PSA in Prostate carcinoma before treatment and after successful treatment are 77.30 ng/ml (n = 53) and 1.64 ng/ml (n = 25) and increase to 53.71 ng/ml (n = 8) in metastasis. In Benign Prostate Hyperplasia (BPH) the range of PSA is 0 - 27.52 ng/ml (n = 74). Phi (φ) coefficient analysis shown that the correlation of PSA and Prostate carcinoma is 63.8% with a sensitivity and specificity of 100% and 86.9% respectively

  17. Roche-lobe overflow systems powered by black holes in young star clusters: the importance of dynamical exchanges

    Energy Technology Data Exchange (ETDEWEB)

    Mapelli, Michela; Zampieri, Luca, E-mail: michela.mapelli@oapd.inaf.it [INAF-Osservatorio Astronomico di Padova, Vicolo dell' Osservatorio 5, I-35122, Padova (Italy)

    2014-10-10

    We have run 600 N-body simulations of intermediate-mass (∼3500 M {sub ☉}) young star clusters (SCs; with three different metallicities (Z = 0.01, 0.1, and 1 Z {sub ☉}). The simulations include the dependence of stellar properties and stellar winds on metallicity. Massive stellar black holes (MSBHs) with mass >25 M {sub ☉} are allowed to form through direct collapse of very massive metal-poor stars (Z < 0.3 Z {sub ☉}). We focus on the demographics of black hole (BH) binaries that undergo mass transfer via Roche lobe overflow (RLO). We find that 44% of all binaries that undergo an RLO phase (RLO binaries) formed through dynamical exchange. RLO binaries that formed via exchange (RLO-EBs) are powered by more massive BHs than RLO primordial binaries (RLO-PBs). Furthermore, the RLO-EBs tend to start the RLO phase later than the RLO-PBs. In metal-poor SCs (0.01-0.1 Z {sub ☉}), >20% of all RLO binaries are powered by MSBHs. The vast majority of RLO binaries powered by MSBHs are RLO-EBs. We have produced optical color-magnitude diagrams of the simulated RLO binaries, accounting for the emission of both the donor star and the irradiated accretion disk. We find that RLO-PBs are generally associated with bluer counterparts than RLO-EBs. We compare the simulated counterparts with the observed counterparts of nine ultraluminous X-ray sources. We discuss the possibility that IC 342 X-1, Ho IX X-1, NGC 1313 X-2, and NGC 5204 X-1 are powered by an MSBH.

  18. Human Papillomavirus Assays and Cytology in Primary Cervical Screening of Women Aged 30 Years and Above

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Bonde, Jesper; Preisler, Sarah

    2016-01-01

    In women aged ≥30 years, Human Papillomavirus testing will replace cytology for primary cervical screening. We compared Hybrid Capture 2 (HC2), cobas, CLART, and APTIMA HPV assays with cytology on 2869 SurePath samples from women undergoing routine screening at 30-65 years in Copenhagen, Denmark....... Women with cytological abnormalities were managed according to routine recommendations, with 92% completeness. Those with cytology-normal/HPV-positive samples (on any of the four assays) were invited for repeated cytology and HPV testing in 1.5 year, and 58% had additional testing. HPV testing detected...... more ≥CIN3 than cytology (HC2: 35, cobas, CLART: 37, APTIMA: 34, cytology: 31), although statistically the differences were not significant. Cobas and CLART detected significantly more ≥CIN2 than cytology (cobas, CLART: 49, cytology: 39). The proportion of women with false-positive test results...

  19. PENGEMBANGAN MODUL SISTEM KEAMANAN JARINGAN BERBASIS SIMULASI CISCO

    Directory of Open Access Journals (Sweden)

    Zulkipli Zulkipli

    2016-03-01

    Tujuan penelitian adalah untuk menghasilkan dan menguji kelayakan modul sistem keamanan jaringan berbasis simulasi Cisco Paket Tracer untuk peserta didik SMK. Model pengembangan yang digunakan adalah model Dick, Carey & Carey dengan sembilan langkah. Pengembangan produk ini divalidasi oleh ahli materi dengan tingkat kevalidan 96%, ahli media dengan tingkat kevalidan 92.8%, ahli desain pembelajaran dengan tingkat kevalidan 83%, uji coba perorangan dengan tingkat kevalidan 92.3%, uji coba kelompok kecil dengan tingkat kevalidan 92% dan uji coba lapangan dengan tingkat kevalidan 89% dengan kualifikasi sangat layak tidak perlu revisi.

  20. PENGEMBANGAN MEDIA KOMIK PEMBELAJARAN MATEMATIKA MENINGKATKAN MOTIVASI DAN PRESTASI BELAJAR SISWA KELAS V

    Directory of Open Access Journals (Sweden)

    Indaryati Indaryati

    2015-01-01

    Full Text Available Penelitian ini bertujuan menghasilkan produk media berupa komik pembelajaran matematika yang dapat meningkatkan motivasi dan prestasi belajar matematika siswa kelas V SD. Penelitian ini merupakan penelitian pengembangan, yang terdiri dari: (1 penelitian dan pengumpulan data, (2 perencanaan, (3 pengembangan draft produk, (4 uji coba lapangan awal,  (5 revisi hasil uji coba, (6 uji coba lapangan, (7 penyempurnaan produk hasil uji coba lapangan, (8 uji pelaksanaan lapangan, dan (9 penyempurnaan produk akhir. Subjek uji coba adalah siswa kelas V SDN Glagah Yogyakarta. Subjek uji coba satu-satu terdiri atas tiga orang siswa. Subjek uji coba kelompok kecil terdiri atas sembilan orang siswa yang belum terlibat dalam uji coba satu-satu, dan subjek uji lapangan terdiri atas 54 orang siswa dari kelas VB dan kelas VC yang tidak ikut dalam uji coba satu-satu dan uji coba kelompok kecil. Hasil penelitian menunjukkan bahwa media yang dikembangkan ini mendapatkan penilaian dari para ahli dengan kategori “baik”, penilaian guru dan siswa yang menggunakan media komik menyatakan praktis, sehingga media pembelajaran ini layak digunakan. Hasil uji lapangan menunjukkan media komik pembelajaran matematika yang digunakan dapat meningkatkan motivasi belajar siswa sebesar 0,65 tergolong dalam kategori sedang menurut skala gain, sedangkan prestasi belajar siswa sebesar 0,73 tergolong dalam kategori tinggi menurut skala gain. ____________________________________________________________________________________________________________________________________ DEVELOPING COMIC MEDIA FOR THE TEACHING OF MATHEMATICS TO ENCHANCE THE MOTIVATION AND MATHEMATICS LEARNING OUTCOMES GRADE V ABSTRACT This research aims to produce a product in the form of mathematics teaching comics which can improve motivation and learning achievement of students of grade V of SD. This research is research and development study consisting of nine stages, namely: (1 research and data collection, (2

  1. Detection and differentiation of Mycobacterium tuberculosis and nontuberculous mycobacterial isolates by real-time PCR.

    Science.gov (United States)

    Shrestha, Nabin K; Tuohy, Marion J; Hall, Gerri S; Reischl, Udo; Gordon, Steven M; Procop, Gary W

    2003-11-01

    Mycobacteria cause a variety of illnesses that differ in severity and public health implications. The differentiation of Mycobacterium tuberculosis from nontuberculous mycobacteria (NTM) is of primary importance for infection control and choice of antimicrobial therapy. Despite advances in molecular diagnostics, the ability to rapidly diagnose M. tuberculosis infections by PCR is still inadequate, largely because of the possibility of false-negative reactions. We designed and validated a real-time PCR for mycobacteria by using the LightCycler system with 18 reference strains and 168 clinical mycobacterial isolates. All clinically significant mycobacteria were detected; the mean melting temperatures (with 99.9% confidence intervals [99.9% CI] in parentheses) for the different mycobacteria were as follows: M. tuberculosis, 64.35 degrees C (63.27 to 65.42 degrees C); M. kansasii, 59.20 degrees C (58.07 to 60.33 degrees C); M. avium, 57.82 degrees C (57.05 to 58.60 degrees C); M. intracellulare, 54.46 degrees C (53.69 to 55.23 degrees C); M. marinum, 58.91 degrees C (58.28 to 59.55 degrees C); rapidly growing mycobacteria, 53.09 degrees C (50.97 to 55.20 degrees C) or 43.19 degrees C (42.19 to 44.49 degrees C). This real-time PCR assay with melting curve analysis consistently accurately detected and differentiated M. tuberculosis from NTM. Detection of an NTM helps ensure that the negative result for M. tuberculosis is a true negative. The specific melting temperature also provides a suggestion of the identity of the NTM present, when the most commonly encountered mycobacterial species are considered. In a parallel comparison, both the LightCycler assay and the COBAS Amplicor M. tuberculosis assay correctly categorized 48 of 50 specimens that were proven by culture to contain M. tuberculosis, and the LightCycler assay correctly characterized 3 of 3 specimens that contained NTM.

  2. IMPLEMENTASI ALGORITMA MONTE CARLO PADA SISTEM INFORMASI PENERIMAAN PESERTA DIDIK BARU (PPDB SECARA ONLINE

    Directory of Open Access Journals (Sweden)

    Muhammad Rizki Irwanto

    2017-08-01

    Full Text Available Tujuan penelitian ini untuk mengimplementasikan algoritma pada sistem in­formasi Penerimaan Peserta Didik Baru (PPDB secara online.Metode penelitian yang digunakan dalam pengembangan sistem informasi ini adalah metode pe­ngem­bang­an Waterfall. Tahap-tahap dalam metode pengembangan Waterfall, ada­lah: (1 de­finisi kebutuhan sistem, (2 desain sistem dan perangkat lunak, (3 im­ple­men­tasi dan pengujian unit, (4 integrasi dan sistem, dan (5 operasi dan pemeliharaan. Hasil uji coba sis­tem informasi oleh ahli rekayasa web dan admin sebesar 100,00%. Data hasil uji coba sistem informasi oleh guru sebesar 84,10%. Sedangkan data hasil uji coba sis­tem informasi oleh siswa sebesar 87,20%. Dari  data hasil uji coba di atas, dapat di­sim­pulkan bahwa sistem informasi ini sudah valid dan siap digunakan di sekolah.

  3. Vitamin B12 absorption judged by measurement of holotranscobalamin, active vitamin B12: evaluation of a commercially available EIA kit.

    Science.gov (United States)

    Greibe, Eva; Nexo, Ebba

    2011-11-01

    Active vitamin B12 absorption is followed by an increase in holotranscobalamin (holoTC) upon loading with a high physiological dose of the vitamin (the CobaSorb test). This study evaluates the use of a newly launched EIA kit for measurement of holoTC (active B12) in relation to the CobaSorb test. Intra-assay imprecision and linearity of the EIA kit was examined, employing serum pools of increasing holoTC concentrations. For the CobaSorb test, holoTC was measured before and after loading with 3-times 9 μg of vitamin B12 employing both the in-house ELISA and the EIA kit (n=25). The EIA kit showed an intra-assay CV between 2.2% and 5.8% for holoTC values ranging from 21 to 80 pmol/L. Employing diluted serum samples resulted in spurious high values of holoTC. The EIA kit performed well in relation to the CobaSorb test and classified the patients studied as capable of absorbing vitamin B12 (n=10) or not (n=15), as did the in-house ELISA. The Active B12 (holoTC) EIA kit proved suitable for use with the CobaSorb test, but not for analysis of diluted serum samples.

  4. Etiology of genital ulcer disease. A prospective study of 278 cases seen in an STD clinic in Paris.

    Science.gov (United States)

    Hope-Rapp, Emilie; Anyfantakis, Vassili; Fouéré, Sebastien; Bonhomme, Philippe; Louison, Jean B; de Marsac, Thibault Tandeau; Chaine, Benedicte; Vallee, Pascale; Casin, Isabelle; Scieux, Catherine; Lassau, François; Janier, Michel

    2010-03-01

    The goal of this study was to identify the causes and factors associated with genital ulcer disease (GUD) among patients attending a sexually transmitted disease (STD) clinic in Paris. This study was a prospective investigation of GUD cases. Data were collected from 1995 to 2005. In each case, a Dark Field Examination (DFE), Gram stain, inoculation onto Thayer Martin agar, Columbia agar and chocolate agar with 1% isovitalex and 20% fetal calf serum, PCR Chlamydia trachomatis (Amplicor Roche), culture for herpes simplex virus (HSV) on MRC 5 cells and PCR HSV (Argene Biosoft) were obtained from the ulceration. First Catch Urine (FCU) PCR for Chlamydia trachomatis and syphilis, HIV, HSV, and HBV serologies were also performed. A total 278 cases of GUD were investigated, 244 (88%) in men and 34 (12%) in women. Primary syphilis accounted for 98 cases (35%), genital herpes for 74 (27%), chancroid for 8 (3%), other infections for 12 (5%). In 91 (32%) patients, no identifiable microorganism was documented. Primary syphilis was more prevalent in MSMs (P chancroid were significantly associated with heterosexuality (both P 10 mm (OR: 9.2 [95% CI: 2.9-30.7], P chancroid and reemergence of infectious syphilis have led to a new distribution of pathogens, genital herpes, primary syphilis and GUD from unknown origin, accounting each for one third of cases. No clinical characteristic is predictive of the etiology, underlining the importance of performing a thorough microbiologic evaluation. Close association with HIV is still a major public health problem.

  5. Low-cost ultra-wide genotyping using Roche/454 pyrosequencing for surveillance of HIV drug resistance.

    Directory of Open Access Journals (Sweden)

    Dawn M Dudley

    Full Text Available Great efforts have been made to increase accessibility of HIV antiretroviral therapy (ART in low and middle-income countries. The threat of wide-scale emergence of drug resistance could severely hamper ART scale-up efforts. Population-based surveillance of transmitted HIV drug resistance ensures the use of appropriate first-line regimens to maximize efficacy of ART programs where drug options are limited. However, traditional HIV genotyping is extremely expensive, providing a cost barrier to wide-scale and frequent HIV drug resistance surveillance.We have developed a low-cost laboratory-scale next-generation sequencing-based genotyping method to monitor drug resistance. We designed primers specifically to amplify protease and reverse transcriptase from Brazilian HIV subtypes and developed a multiplexing scheme using multiplex identifier tags to minimize cost while providing more robust data than traditional genotyping techniques. Using this approach, we characterized drug resistance from plasma in 81 HIV infected individuals collected in São Paulo, Brazil. We describe the complexities of analyzing next-generation sequencing data and present a simplified open-source workflow to analyze drug resistance data. From this data, we identified drug resistance mutations in 20% of treatment naïve individuals in our cohort, which is similar to frequencies identified using traditional genotyping in Brazilian patient samples.The developed ultra-wide sequencing approach described here allows multiplexing of at least 48 patient samples per sequencing run, 4 times more than the current genotyping method. This method is also 4-fold more sensitive (5% minimal detection frequency vs. 20% at a cost 3-5× less than the traditional Sanger-based genotyping method. Lastly, by using a benchtop next-generation sequencer (Roche/454 GS Junior, this approach can be more easily implemented in low-resource settings. This data provides proof-of-concept that next

  6. Contribution à l'étude de la "taille" des roches Contribution to the Study of Rock Cutting

    Directory of Open Access Journals (Sweden)

    Nguyenminh D.

    2006-11-01

    Full Text Available Une étude expérimentale détaillée du processus local de destruction des roches par un outil de forage pétrolier a été faite par une méthode de similitude utilisant des matériaux équivalents tendres. On examine l'influence de la forme de l'outil, de la rugosité du contact et de la ductilité e globale » du matériau. Les résultats obtenus sont ensuite comparés à ceux de l'analyse plastique par la théorie des charges limites. Cette étude met en évidence l'existence de deux modes de rupture, l'action différente du frottement superficiel selon le sens de l'écoulement relatif du matériau en contact, le phénomène de la ductilité apparente qui dépend de la forme de l'outil ; elle précise les paramètres mécaniques importants du forage. A detailed experimental investigation of the local process of rock cutting by a drill bit was carried out on soft equivalent materials simulating rock under borehole conditions. Different factors were analyzed : the shape of the bit tooth, the roughness of ifs contact area, the average ductility of the materiat. The results obtained are then compared with those from a plastic analysis based on the peak lood theory. This investigation shows that there are two different modes of rock destruction, that the Coulomb friction has a different effect depending on the relative direction of flow of the materiat in contact with the bit, and that an apparent ductility of the materiat is linked to the shape of the bit teeth. Finally, the basic mechanical variables for drilling are described

  7. Detection of cervical precancerous lesions with Aptima HPV assays using SurePath preservative fluid specimens

    Directory of Open Access Journals (Sweden)

    Max Chernesky

    2017-06-01

    Full Text Available SurePath specimens from women referred to colposcopy were treated with Aptima Transfer Solution (ATS before testing in Aptima HPV (AHPV and Aptima HPV 16, 18/45 (AHPV-GT assays. Untreated SurePath specimens were tested with the cobas HPV test. PreservCyt specimens were assessed for cytology and tested with AHPV. High-grade cervical intraepithelial neoplasia lesions served as the reference standard. Excellent agreement (95.5%; k=0.91 was observed for ATS-treated SurePath specimens between Tigris and Panther systems and between the PreservCyt and ATS-treated SurePath specimens (91.1%, k=0.81 with the AHPV assay on Tigris. Agreement between the AHPV and cobas assays with SurePath specimens was substantial (89.9%, k=0.80. AHPV sensitivity for CIN2+(n=147 was 91.2% for SurePath and PreservCyt. Cobas HPV sensitivity was 93.9% for SurePath specimens. AHPV testing of SurePath specimens was more specific (59.4% than cobas (54.7% (p<0.001. Detection and genotyping showed similar absolute and relative risks. ATS-treated SurePath specimens tested with AHPV and AHPV-GT assays showed similar performance with greater specificity than cobas HPV on SurePath specimens. Similar overall results were seen using a CIN3 disease endpoint. Keywords: Human papillomavirus, SurePath, PreservCyt, Cervical intraepithelial neoplasia, CIN2+, Aptima transfer solution (ATS

  8. Analysis of 16S rRNA amplicon sequencing options on the Roche/454 next-generation titanium sequencing platform.

    Directory of Open Access Journals (Sweden)

    Hideyuki Tamaki

    Full Text Available BACKGROUND: 16S rRNA gene pyrosequencing approach has revolutionized studies in microbial ecology. While primer selection and short read length can affect the resulting microbial community profile, little is known about the influence of pyrosequencing methods on the sequencing throughput and the outcome of microbial community analyses. The aim of this study is to compare differences in output, ease, and cost among three different amplicon pyrosequencing methods for the Roche/454 Titanium platform METHODOLOGY/PRINCIPAL FINDINGS: The following three pyrosequencing methods for 16S rRNA genes were selected in this study: Method-1 (standard method is the recommended method for bi-directional sequencing using the LIB-A kit; Method-2 is a new option designed in this study for unidirectional sequencing with the LIB-A kit; and Method-3 uses the LIB-L kit for unidirectional sequencing. In our comparison among these three methods using 10 different environmental samples, Method-2 and Method-3 produced 1.5-1.6 times more useable reads than the standard method (Method-1, after quality-based trimming, and did not compromise the outcome of microbial community analyses. Specifically, Method-3 is the most cost-effective unidirectional amplicon sequencing method as it provided the most reads and required the least effort in consumables management. CONCLUSIONS: Our findings clearly demonstrated that alternative pyrosequencing methods for 16S rRNA genes could drastically affect sequencing output (e.g. number of reads before and after trimming but have little effect on the outcomes of microbial community analysis. This finding is important for both researchers and sequencing facilities utilizing 16S rRNA gene pyrosequencing for microbial ecological studies.

  9. [Utilization of self-sampling kits for HPV testing in cervical cancer screening - pilot study].

    Science.gov (United States)

    Ondryášová, H; Koudeláková, V; Drábek, J; Vaněk, P; Slavkovský, R; Hajdúch, M

    2015-12-01

    To get initial experience with alternative sampling (self-sampling) for HPV testing as the means of cervical cancer screening program. Original work. Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University in Olomouc. Based on expression of interest, 215 self-sampling kits were posted to women. Evalyn(®) Brush Vaginal swabs obtained by self-sampling were analyzed for the presence of HPV infection by Cobas 4800 HPV (Roche) followed by genotyping using PapilloCheck(®) HPV-Screening (Greiner Bio-One). Sixty women randomly chosen from our sample were sent a questionnaire focused on their experience with self-sampling. One hundred seventy-four of 215 (81%) distributed self-sampling devices have been delivered to analysis. All cervicovaginal swabs were sampled correctly and it was possible to analyze them by Cobas 4800 HPV test. Similarly, 98% (171/174) samples were analyzable by PapilloCheck(®) HPV-Screening.One hundred twenty-five (72%) of 174 tested samples were HPV negative. Low risk HPV infection was detected only in 7 samples (4%), and high risk HPV (hrHPV) infection was present in 42 samples (24%). The most frequently detected hrHPV genotypes were HPV16 (11/42; 26%) and HPV53 (6/42; 14%). HrHPV co-infection was detected in 10 cases, in 5 of them lrHPV infection was find also.Of the 60 questionnaires, 48 (80%) were returned. From this group, 47 (98%) women rated their experience with self-sampling device as good to excellent. User manual of self-sampling device was considered good to excellent by all women (100%). All women also rated the convenience of self-sampling device using as good to excellent. As expected, most of the women (n = 42 [88%]) preferred self-sampling to physician sampling. Cervicovaginal self-sampling leads to valid results of HPV screening using two molecular genetics methods and was accepted by Czech women very well. The self-sampling as an opportunity to participate in cervical cancer

  10. PENGEMBANGAN PROTOTIPE EGG BOILER SEBAGAI MEDIA PEMBELAJARAN PRAKARYA DAN KEWIRAUSAHAAN UNTUK MATERI TEKNOLOGI TEPAT GUNA KELAS XI MIA SMA NEGERI 4 SINGARAJA TAHUN AJARAN 2016/2017

    Directory of Open Access Journals (Sweden)

    Indra Kusuma Harta

    2017-07-01

    Full Text Available Penelitian ini bertujuan untuk mengembangkan Prototipe Egg Boiler (Pengkukus Telur Otomatis sebagai media pembelajaran untuk mata pelajaran Prakarya dan Kewirausahaan pada materi Teknologi Tepat Guna di Kelas XI MIA SMA Negeri 4 Singaraja. Penelitian ini dilakukan dengan menggunakan metode Penelitian dan Pengembangan dalam bidang pendidikan. Hasil uji validasi ahli media memperoleh skor sebesar 0,75 dalam kategori tinggi. Uji validasi isi dengan nilai sebesar 0,81 dalam kategori sangat tinggi.  Sedangkan hasil uji coba perorangan dengan nilai sebesar 0.93, uji coba kelompok kecil dengan nilai sebesar 0.71, dan uji coba lapangan dengan nilai sebesar 0.82. Pada uji coba lapangan juga dilakukan dengan menganalisis nilai dari kegiatan praktikum, nilai yang diperoleh 87.4 dikategorikan dengan hasil belajar tinggi. Dari hasil nilai pre-test dan post-test tersebut secara keseluruhan mengalami peningkatan. Sehingga Pototipe Egg Boiler yang telah dikembangkan sangat membantu siswa dalam memahami materi dan praktikum mata pelajaran Prakarya dan Kewirausahaan untuk materi Teknologi Tepat Guna di Kelas XI MIA SMA Negeri 4 Singaraja.

  11. Détermination de la mouillabilité d'un échantillon de roche-réservoir Determining the Wettability of a Resevoir-Rock Sample

    Directory of Open Access Journals (Sweden)

    Cuiec L.

    2006-11-01

    Full Text Available L'objet de cet article est la description d'une méthode de laboratoire permettant l'évaluation de la mouillabilité d'une roche-réservoir vis-à-vis d'un couple eau-huile. Dans une première partie, on donne une définition du paramètre mouillabilité et on précise les conditions requises pour le mesurer valablement, une analyse critique rapide des différentes méthodes de mesure est effectuée. Elle permet de justifier le choix d'une méthode qui est décrite dans la seconde partie. De nombreux exemples d'application sont donnés à titre d'illustration. The aim of this article is to describe a laboratory method for evaluating the wettability of a reservoir rock with regard ta a water-oil system.The first part gives a définition of the wettability parameter and specifiesthe conditions required for volidly measuring it. A brief critical analysis is made of different measuring methods. This onalysis justifies the choice of a method which is described in the second part. A great many application examples are given to illustrate this.

  12. Une méthode précise pour la mise en évidence et l'étude de l'anisotropie dans les roches An Accurate Method for Detecting and Analyzing Anisotropy in Rocks

    Directory of Open Access Journals (Sweden)

    Talebi S.

    2006-11-01

    Full Text Available L'objectif essentiel de cette recherche était de mettre au point une méthode expérimentale pour étudier l'anisotropie de la vitesse des ondes longitudinales (P dans les roches. Cette anisotropie aurait deux causes principales : d'une part, l'existence d'un réseau de pores, de fissures ou de microfissures, distribué de façon anisotrope dans la roche et d'autre part, la structure elle-même, dont l'anisotropie résulte de la nature des minéraux et de leur disposition. Dans un premier temps, nous avons commencé les essais sur des échantillons de carotte, forés dans trois directions perpendiculaires X, Y et Z d'un bloc de deux types de grès : grès des Vosges et grès de Fontainebleau. La vitesse du son a été mesurée sur 3 à 4 sections de carotte avec des intervalles de 30° (6 directions. Elles se distribuent nettement selon une ellipse, appelée l'ellipse d'anisotropie. Ces ellipses ont été tracées par mini-ordinateur et ont permis de mettre en évidence l'état d'anisotropie et l'homogénéité des carottes. La méthode est tellement précise qu'une erreur de repérage des axes sur un échantillon (Y de grès des Vosges a été détectée et certifiée à l'aide de direction des micas. Nous avons effectué le même essai sur les mêmes échantillons saturés sous vide. Une tendance générale à l'augmentation des vitesses, la diminution du degré d'anisotropie (le rapport de Vmax/Vmin et le changement de position de l'axe d'anisotropie a été observée. La comparaison des résultats secs et saturés permet d'avoir une idée de la nature des vides et de leur rôle dans l'anisotropie globale. Dans l'étape suivante de l'étude, nous avons mis au point une méthode de mesure sur les cubes à faces tronquées (66 faces au maximum de différents types de roches (2 grès, 2 marbres, 1 andésite, 1 balsate, et 1 calcaire. Les valeurs de vitesses des ondes (P ont été mesurées et reportées sur un diagramme de Schmidt. Ensuite

  13. Evaluation of the Roche prototype 454 HIV-1 ultradeep sequencing drug resistance assay in a routine diagnostic laboratory.

    Science.gov (United States)

    Garcia-Diaz, A; Guerrero-Ramos, A; McCormick, A L; Macartney, M; Conibear, T; Johnson, M A; Haque, T; Webster, D P

    2013-10-01

    Studies have shown that low-frequency resistance mutations can influence treatment outcome. However, the lack of a standardized high-throughput assay has precluded their detection in clinical settings. To evaluate the performance of the Roche prototype 454 UDS HIV-1 drug resistance assay (UDS assay) in a routine diagnostic laboratory. 50 plasma samples, previously characterized by population sequencing and that had shown ≥1 resistance associated mutation (RAM), were retrospectively tested by the UDS assay, including 18 B and 32 non-B subtypes; viral loads between 114-1,806,407 cp/ml; drug-naive (n=27) and drug-experienced (n=23) individuals. The UDS assay was successful for 37/50 (74%) samples. It detected all RAMs found by population sequencing at frequencies above 20%. In addition, 39 low-frequency RAMs were exclusively detected by the UDS assay at frequencies below 20% in both drug-naïve (19/26, 73%) and drug-experienced (9/18, 50%) individuals. UDS results would lead to changes from susceptible to resistant to efavirenz (EFV) in one drug-naive individual with suboptimal response to an EFV-containing regimen and from susceptible to resistance to lamivudine (3TC) in one drug naïve subject who subsequently failed a 3TC-containing regimen and in a treatment experienced subject who had failed a 3TC-containing regimen. The UDS assay performed well across a wide range of subtypes and viral loads; it showed perfect agreement with population sequencing for all RAMs analyzed. In addition, the UDS assay detected additional mutations at frequencies below 20% which correlate with patients' treatment history and had in some cases important prognostic implications. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. An evaluation of clinical performance of FTA cards for HPV 16/18 detection using cobas 4800 HPV Test compared to dry swab and liquid medium.

    Science.gov (United States)

    Dong, Li; Lin, Chunqing; Li, Li; Wang, Margaret; Cui, Jianfeng; Feng, Ruimei; Liu, Bin; Wu, Zeni; Lian, Jia; Liao, Guangdong; Chen, Wen; Qiao, Youlin

    2017-09-01

    Effective dry storage and transport media as an alternative to conventional liquid-based medium would facilitate the accessibility of women in the low-resource settings to human papillomavirus (HPV)- based cervical cancer screening. To evaluate analytical and clinical performance of indicating FTA™ Elute Cartridge (FTA card) for the detection of HPV16/18 and cervical precancerous lesions and cancer compared to dry swab and liquid medium. Ninety patients with abnormal cytology and/or HPV infection were included for analysis. Three specimens of cervical exfoliated cells from each woman were randomly collected by FTA card, dry swab or liquid-based medium prior to colposcopy examination. The subsequent HPV DNA tests were performed on cobas 4800 HPV platform. High-risk HPV (hrHPV) positivity rate was 63.3%, 62.2% and 65.6% for samples collected by FTA card, dry swab and liquid medium, respectively. The overall agreements and kappa values for the detection of hrHPV, HPV 16 and HPV 18 between FTA card and liquid-based medium were 88.9% (κ=0.76), 97.8% (κ=0.94) and 100% (κ=1.0),respectively; between FTA card and dry swab were 92.1% (κ=0.83), 94.5% (κ=0.87) and 100% (κ=1.0), respectively. The performances of hrHPV tested by FTA card, dry swab, and liquid-based medium for detecting CIN2+ were comparable in terms of the sensitivity and specificity. The specificity of detection of CIN2+ by HPV16/18 increased by approximately 40% compared to hrHPV for any medium albeit at cost of a moderate loss of sensitivity. Dry medium might offer an alternative to conventional liquid-based medium in the HPV-based cervical cancer screening program especially in low-resource settings but still needs further evaluation. Copyright © 2017. Published by Elsevier B.V.

  15. Indeterminate RIBA results were associated with the absence of hepatitis C virus RNA (HCV-RNA) in blood donors.

    Science.gov (United States)

    Pereira, Felicidade Mota; Zarife, Maria Alice Sant'ana; Reis, Eliana Almeida Gomes; G Reis, Mitermayer

    2014-01-01

    Hepatitis C virus (HCV) infection is diagnosed by the presence of antibodies and is supplemented by confirmatory testing methods, such as recombinant immunoblot assay (RIBA) and HCV-RNA detection. This study aimed to evaluate the efficacy of RIBA testing to diagnose HCV infection in blood donors positive for anti-HCV antibodies. A total of 102 subjects positive for anti-HCV determined by enzyme-linked immunosorbent assay (ELISA) at the Hematology and Hemotherapy Foundation of Bahia (HEMOBA) were later assessed with new samples using the Abbott Architect anti-HCV test (Abbott Diagnostics, Wiesbaden, Germany), the RIBA III test (Chiron RIBA HCV 3.0 SIA, Chiron Corp., Emeryville, CA, USA), the polymerase chain reaction (PCR; COBAS® AMPLICOR HCV Roche Diagnostics Corp., Indianapolis, IN, USA) and line probe assay (LiPA - Siemens, Tarrytown, NY, USA) genotyping for HCV diagnosis. Of these new samples, 38.2% (39/102) were positive, 57.8% (59/102) were negative and 3.9% (4/102) were indeterminate for anti-HCV; HCV-RNA was detected in 22.5% (23/102) of the samples. RIBA results were positive in 58.1% (25/43), negative in 9.3% (4/43) and indeterminate in 32.6% (14/43) of the samples. The prevailing genotypes were 1 (78.3%, 18/23), 3 (17.4%, 4/23) and 2 (4.3%, 1/23). All 14 samples with indeterminate RIBA results had undetectable viral loads (detection limit ≤50 IU/mL). Of these samples, 71.4% (10/14) were reevaluated six months later. Eighty percent (8/10) of these samples remained indeterminate by RIBA, and 20% (2/10) were negative. In this study, individuals with indeterminate RIBA results had no detectable HCV-RNA.

  16. Avaliação de diferentes métodos imunoturbidimétricos para determinação de albumina urinária: impacto na classificação dos estágios da nefropatia diabética Evaluation of different immunoturbidimetric methods to measure urinary albumin: impact in the classification of diabetic nephropathy stages

    Directory of Open Access Journals (Sweden)

    Andrea Elisabet Wendland

    2007-12-01

    Full Text Available INTRODUÇÃO: A nefropatia diabética (ND acomete até 40% dos pacientes diabéticos e o diagnóstico precoce pode evitar a evolução para estágios avançados. O rastreamento deve ser realizado pela medida de albumina urinária (AlbU utilizando-se o método quantitativo sensível. OBJETIVO: Avaliar diferentes métodos imunoturbidimétricos de determinação de AlbU para a classificação dos estágios da ND. MATERIAL E MÉTODO: A albumina foi dosada em 167 urinas (65 urinas de 24 h e 102 amostras casuais por dois métodos imunoturbidimétricos: kit Aptec-BioSys, ADVIA® 1650 Bayer (AlbUAdvia e kit MAlb Urin-Pack Bayer®, CobasMira® Roche(AlbUCobas. AlbUCobas foi definido como método comparativo e utilizado para classificar as amostras em normoalbuminúricas (albuminúria 300 mg/24 h ou > 174 mg/l, n = 31. Os coeficientes de variação (CV intra e interensaio, sensibilidade e linearidade dos métodos foram calculados. As concordâncias analítica e diagnóstica foram analisadas por regressão Deming, gráficos de Bland-Altman e por coeficiente kappa. RESULTADOS: Os CVs intra e interensaio foram BACKGROUND: Diabetic nephropathy (DN affects up to 40% of diabetic patients and must be screened by the measurement of urinary albumin with a sensitive quantitative method. OBJECTIVE: To evaluate the impact of different immunoturbidimetric methods to measure albuminuria in the classification of DN stages. MATERIAL AND METHOD: Albumin was measured in 167 urine samples (65 24 h samples and 102 casual samples by two immunoturbidimetric methods: Aptec BioSys, ADVIA® 1650 Bayer (AlbUAdvia and Malb Urin-Pack Bayer®, CobasMira® Roche (AlbUCobas. AlbUCobas was definedas the comparative method used to classify the samples in: normoalbuminuric (albuminuria 300 mg/24 h or > 174 mg/l; n = 31. The intra and interassay coefficients of variation (CVs, sensitivity and linearity of each method were calculated and the analytical and diagnostic agreements were

  17. PENGEMBANGAN ASESMEN ALTERNATIF PRAKTIKUM KIMIA DASAR II MELALUI CHEMISTRY FAIR PROJECT (CFP BERBASIS KONSERVASI DENGAN MEMANFAATKAN DAILY CHEMICAL

    Directory of Open Access Journals (Sweden)

    Indah Urwatin Wusqo

    2016-12-01

    Full Text Available Penelitian ini bertujuan untuk (1 Mengembangkan asesmen alternatif pada praktikum kimia dasar II melalui chemistry fair project berbasis konservasi dengan memanfaatkan daily chemical(2 Mengetahui tingkat kevalidan, kepraktisan dan keefektifannya. Penelitian ini merupakan penelitian pengembangan (Development Research Model pengembangan yang diterapkan Dick dan Carey (1985. Subjek uji coba terbatas maupun subjek uji coba lapangan adalah dosen dan mahasiswa Prodi Pendidikan IPA UNNES. Sampel ditentukan secara purposive, yaitu dosen pengampu dan mahasiswa yang menempuh mata kuliah Praktikum Kimia Dasar II. Data yang diperoleh dari uji coba ini adalah: (1 masukan dari pakar, untuk menentukan validitas isi dan konstruk dari fitur asesmen; (2 masukan dari sampel uji coba terbatas, untuk menentukan kepraktisan petunjuk chemistry fair project (CFP berbasis konservasi dengan memanfaatkan daily chemical ; Instrumen pengumpul data berupa angket keterbacaan petunjuk pembuatan chemistry fair project (CFP berbasis konservasi dengan memanfaatkan daily chemical, pedoman penskoran. (3 data hasil belajar siswa untuk mengetahui efektivitas asesmen. Masukan dari pakar angket mahasiswa, dan nilai chemistry fair project (CFP sampel ujicoba terbatas dianalisis secara kualitatif, dan kuantitatif. Asesmen alternative Praktikum Kimia Dasar II yang dikembangkan dikatakan berhasil baik apabila asesmen yang dikembangkan valid, praktis, dan efektif.

  18. Method of chemical analysis of silicate rocks (1962); Methode d'analyse chimique des roches silicatees (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Pouget, R [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1962-07-01

    A rapid method of analysis for the physical and chemical determination of the major constituents of silicate rocks is described. Water losses at 100 deg. C and losses of volatile elements at 1000 deg. C are estimated after staying in oven for these temperatures, or by mean of a thermo-balance. The determination of silica is made by a double insolubilization with hydrochloric acid on attack solution with sodium carbonate; total iron and aluminium, both with calcium and magnesium, after ammoniacal precipitation of Fe and Al, are determined on the filtration product of silica by titrimetry-photometry of their complexes with EDTA. The alkalis Na and K by flame spectrophotometry, Mn by colorimetry of the permanganate, and Ti by mean of his complex with H{sub 2}O{sub 2}, are determined on fluosulfuric attack solution. Phosphorus is determined by his complex with 'molybdenum blue' on a fluoro-nitro-boric attack solution; iron is estimated by potentiometry, with the help of bichromate on hydrofluoric solution. (author) [French] Une methode d'analyse rapide est decrite pour la determination physico-chimique des constituants principaux des roches silicatees. Les pertes en eau a 100 deg. C et en matieres volatiles a 1000 deg. C sont evaluees apres passage au four a ces temperatures, ou a l'aide d'une thermobalance. La determination de la silice se fait par double insolubilisation a l'acide chlorhydrique, sur une attaque au carbonate de sodium; le fer total et l'aluminium ainsi que le calcium et le magnesium, apres precipitation a l'ammoniaque des deux premiers metaux, sont determines sur le filtrat de la silice par titrimetrie-photometrie de leurs complexes avec l'E.D.T.A. Les alcalins sodium et potassium par spectrophotometrie de flamme, le manganese par colorimetrie du permanganate, le titane a l'aide de son complexe avec l'eau oxygenee, sont determines sur une attaque fluosulfurique. Le phosphore est determine par son complexe du 'bleu de molybdene' sur une attaque fluo

  19. The equilibrium of rubble-pile satellites: The Darwin and Roche ellipsoids for gravitationally held granular aggregates

    Science.gov (United States)

    Sharma, Ishan

    2009-04-01

    Many new small moons of the giant planets have been discovered recently. In parallel, satellites of several asteroids, e.g., Ida, have been found. Strikingly, a majority of these new-found planetary moons are estimated to have very low densities, which, along with their hypothesized accretionary origins, suggests a rubble internal structure. This, coupled to the fact that many asteroids are also thought to be particle aggregates held together principally by self-gravity, motivates the present investigation into the possible ellipsoidal shapes that a rubble-pile satellite may achieve as it orbits an aspherical primary. Conversely, knowledge of the shape will constrain the granular aggregate's orbit—the closer it gets to a primary, both primary's tidal effect and the satellite's spin are greater. We will assume that the primary body is sufficiently massive so as not to be influenced by the satellite. However, we will incorporate the primary's possible ellipsoidal shape, e.g., flattening at its poles in the case of a planet, and the proloidal shape of asteroids. In this, the present investigation is an extension of the first classical Darwin problem to granular aggregates. General equations defining an ellipsoidal rubble pile's equilibrium about an ellipsoidal primary are developed. They are then utilized to scrutinize the possible granular nature of small inner moons of the giant planets. It is found that most satellites satisfy constraints necessary to exist as equilibrated granular aggregates. Objects like Naiad, Metis and Adrastea appear to violate these limits, but in doing so, provide clues to their internal density and/or structure. We also recover the Roche limit for a granular satellite of a spherical primary, and employ it to study the martian satellites, Phobos and Deimos, as well as to make contact with earlier work of Davidsson [Davidsson, B., 2001. Icarus 149, 375-383]. The satellite's interior will be modeled as a rigid-plastic, cohesion-less material

  20. Generation of Anomalous Internal Pressures in Source Rocks and Its Role in Driving Petroleum Migration La genèse de pressions internes anormales dans les roches mères et son rôle de poussée dans la migration du pétrole

    Directory of Open Access Journals (Sweden)

    Barker C.

    2006-11-01

    . La présence de gaz conduit à des comportements très différents et la pression de pores dans les roches mères inférieure à la normale à moins qu'il n'y ait une genèse suffisante de la matière organique en hydrocarbures pour la compenser. En l'absence d'une genèse continue (c'est-à-dire pour le méthane biogénique, le gaz se dissout régulièrement et les pressions chutent considérablement en dessous de la pression hydrostatique. A l'inverse, sur les élévations, les systèmes gazéifères ont tendance à la surpression et la pression peut atteindre la charge de fracturation de la roche. Le craquage thermique des bitumes qui restent dans une roche mère au cours de l'enfouissement va de pair avec une augmentation de volume et, dans un pore isolé, le système des pressions atteint des valeurs élevées. Il suffit qu'un pour cent des bitumes de type huile soit transformé en gaz pour que la pression atteigne la charge pour laquelle la fracturation de la roche est une conséquence inévitable.

  1. Evaluation of the highly sensitive Roche thyroglobulin II assay and establishment of a reference limit for thyroglobulin-negative patient samples.

    Science.gov (United States)

    Rotteveel-de Groot, Dorien M; Ross, H Alec; Janssen, Marcel J R; Netea-Maier, Romana T; Oosting, Janine D; Sweep, Fred C G J; van Herwaarden, Antonius E

    2016-08-01

    Thyroglobulin (Tg) measurements are used to monitor for residual thyroid tissue in patients with differentiated thyroid cancer (DTC) after thyroidectomy and radioiodine ablative therapy. In recent years highly sensitive Tg assays have been developed. In this study the analytical performance of the new Roche Elecsys Tg II assay was evaluated and compared with the well documented Access2 Tg assay (Beckman-Coulter). Analytical performance was examined using various Clinical and Laboratory Standards Institute (CLSI) evaluation protocols. Tg negative patient sera were used to establish an upper reference limit (URL) for the Elecsys Tg II assay. Non-linearity, drift and carry-over according to CLSI EP10 and EP6 in a measuring range of 0.04-500 ng/mL were non-significant. Total precision according to CLSI EP5 was 10% at a Tg concentration of 0.08 ng/mL. A patient serum comparison performed according to a modified CLSI EP9 protocol showed a significant difference of a factor of approximately 1.4, despite using an identical CRM calibrator. The Elecsys Tg II assay measured Tg with a two-fold higher sensitivity than the Access2 assay. Finally, using human sera without Tg, an URL of 0.05 ng/mL was determined. In our hands the highly sensitive Elecsys Tg II assay shows a good analytical performance and a higher sensitivity compared to the Access2 Tg assay. An URL of 0.05 ng/mL for the Elecsys Tg II assay was determined which may improve the clinical utility of the assay for the detection of residual DTC or disease recurrence.

  2. Méthode rapide de caractérisation des roches mètres, de leur potentiel pétrolier et de leur degré d'évolution Rapid Method for Source Rocks Characrerysation and for Determination of Petroleum Potential and Degree of Evolution

    Directory of Open Access Journals (Sweden)

    Espitalié J.

    2006-11-01

    Full Text Available Les études fondamentales réalisées sur les kérogènes à l'aide de diverses méthodes physico-chimiques d'analyse ont permis de mettre au point une méthode et un appareillage adaptés à l'exploration pétrolière. On expose dans cet article la mise au point de cette méthode et on montre, à l'aide des paramètres qu'elle permet d'obtenir, ses applications dans le domaine de l'exploration pétrolière - reconnaissance des différents types de roche mère et de leur potentiel pétrolier; - caractérisation de leur degré d'évolution (zone à huile - zone à gaz. On montre aussi que cette méthode convient particulièrement bien à l'estimation du rendement en huile des roches bitumineuses et à l'étude de la qualité et du rang des charbons. Fundamental research on kerogens by different physico-chemical analysis methods have led to the development of a method and equipment suited for petroleum exploration. This article describes the development of this method and, by means of the parameters it determines, shows how it con be applied in the field of petroleum exploration - exploring different types of source rock and their petroleum potential ; - characterizing their degree of evolution (ail zone/gas zone. This method is also shown ta be particularly suited for estimating the oil yield of cil shales and investigating the quality and classification of cool.

  3. Development of Fe-based superconducting wires for liquid-hydrogen level sensors

    Science.gov (United States)

    Ishida, S.; Tsuchiya, Y.; Mawatari, Y.; Eisaki, H.; Nakano, A.; Yoshida, Y.

    2017-07-01

    We developed liquid-hydrogen (LH2) level sensors with Ba(Fe1-x Co x )2As2 superconducting wires (Co-Ba122 wires) as their detection elements. We fabricated Co-Ba122 wires with different Co concentrations x by using the powder-in-tube method. The superconducting transition temperatures of the wires were successfully controlled in the range of 20-25 K by changing x from 0.06 to 0.10. The resistance-temperature curves of the wires exhibited sharp superconducting transitions with widths of 0.5-1.0 K. In addition, we performed an operation test of the Co-Ba122 level sensors with LH2. Close correspondence between the output resistance and the actual LH2 level was observed for a sensor equipped with x = 0.09 wire, demonstrating that this sensor can accurately measure LH2 levels.

  4. Biochemically Investigation of the Effects of Nettle Seed Herbal Mixture on Alcohol Damaged Liver

    Directory of Open Access Journals (Sweden)

    A. ÇELİK

    2014-06-01

    Full Text Available It was experimentally investigated in this research how protective Nettle Seed Herbal Mixture is against ethanol which causes oxidative stress in rats and causes toxic effects in the liver with chronic use. 20 4-month-old female Wistar male rats were used in the study. All rats in the study were fed with normal pellet Mouse food during the experiment. 10 week application was done by dividing the rats into four equal groups. Application method is orally drinking method. First group is the control group. The second group is the alcohol group. This group was given 30% ethanol in order to cause chronic alcoholisms. The third group was the alcohol+ Nettle Seed Herbal Mixture group and the rats in this group were given liquid, which was 30% ethanol,+ Nettle Seed Herbal Mixture extract. Fourth group was Nettle Seed Herbal Mixture extract group and the rats in this group were given liquid, which was Nettle Seed Herbal Mixture extract. At the end of ten weeks, within the first 24 hours, blood species were obtained from the animals under anesthesia using appropriate techniques. Serum ALT and AST values of the obtained blood samples were studied by enzymatic methods in "Roche Cobas 6000" device.. Biochemically ALT and AST enzyme values and statistical analysis with SPSS programe were done. No significant difference was found between these four groups at the end of the analysis because p value was bigger than 0,005.

  5. Biological Variation and Reference Change Value Data for Serum Neuron-Specific Enolase in a Turkish Population.

    Science.gov (United States)

    Matyar, Selcuk; Goruroglu Ozturk, Ozlem; Ziyanoglu Karacor, Esin; Yuzbasioglu Ariyurek, Sedefgul; Sahin, Gulhan; Kibar, Filiz; Yaman, Akgun; Inal, Tamer

    2016-11-01

    Neuron-specific enolase (NSE) is a recognized biomarker for the assessment of cerebral injury in neurological disorders. This study aims to report a definitive assessment of the biological variation (BV) components of this biomarker, including within-subject BV (CVI), between-subject BV (CVG), index of individuality (II), and reference change value (RCV), in a cohort of Turkish participants using an experimental protocol. Six blood specimens were collected from each of the 13 apparently healthy volunteers (seven women, six men; ranging in age from 23 to 36) on the same day, every 2 weeks for 2 months. Serum specimens were stored at -20°C until analysis. Neuron-specific enolase levels were evaluated in serum samples using an electrochemiluminescence (ECLIA) immunoassay kit with a Roche Cobas e 411 auto-analyser. ANOVA test was used to calculate the variations. The CVI and CVG for NSE were 21.5% and 28.8%, respectively. Analytical variation (CVA) was calculated as 10.2%. Additionally, II and RCV were calculated as 0.74 and 66% (95% confident interval, CI), respectively. As the performance index (PI) was found to be less than 2 (PI = 0.95), it is concluded that the NSE measurements have a desirable performance for analytical imprecision. Since the II was found to be less than 1 (II: 0.74), the reference values will be of little use. Thus, RCV would provide better information for deciding whether a significant change has occurred. © 2016 Wiley Periodicals, Inc.

  6. Influence of centrifugation conditions on the results of 77 routine clinical chemistry analytes using standard vacuum blood collection tubes and the new BD-Barricor tubes.

    Science.gov (United States)

    Cadamuro, Janne; Mrazek, Cornelia; Leichtle, Alexander B; Kipman, Ulrike; Felder, Thomas K; Wiedemann, Helmut; Oberkofler, Hannes; Fiedler, Georg M; Haschke-Becher, Elisabeth

    2018-02-15

    Although centrifugation is performed in almost every blood sample, recommendations on duration and g-force are heterogeneous and mostly based on expert opinions. In order to unify this step in a fully automated laboratory, we aimed to evaluate different centrifugation settings and their influence on the results of routine clinical chemistry analytes. We collected blood from 41 healthy volunteers into BD Vacutainer PST II-heparin-gel- (LiHepGel), BD Vacutainer SST II-serum-, and BD Vacutainer Barricor heparin-tubes with a mechanical separator (LiHepBar). Tubes were centrifuged at 2000xg for 10 minutes and 3000xg for 7 and 5 minutes, respectively. Subsequently 60 and 21 clinical chemistry analytes were measured in plasma and serum samples, respectively, using a Roche COBAS instrument. High sensitive Troponin T, pregnancy-associated plasma protein A, ß human chorionic gonadotropin and rheumatoid factor had to be excluded from statistical evaluation as many of the respective results were below the measuring range. Except of free haemoglobin (fHb) measurements, no analyte result was altered by the use of shorter centrifugation times at higher g-forces. Comparing LiHepBar to LiHepGel tubes at different centrifugation setting, we found higher lactate-dehydrogenase (LD) (P = 0.003 to centrifuged at higher speed (3000xg) for a shorter amount of time (5 minutes) without alteration of the analytes tested in this study. When using LiHepBar tubes for blood collection, a separate LD reference value might be needed.

  7. Hepatitis C virus genotyping of organ donor samples to aid in transplantation of HCV-positive organs.

    Science.gov (United States)

    Gentile, Caren; Van Deerlin, Vivianna M; Goldberg, David S; Reese, Peter P; Hasz, Richard D; Abt, Peter; Blumberg, Emily; Farooqi, Midhat S

    2018-02-01

    Given the availability of new highly efficacious anti-HCV therapies, some clinicians have advocated for wider use of kidneys from hepatitis C virus-positive (HCV+) donors, including transplanting them into HCV-negative recipients. As treatment regimens for HCV are commonly guided by genotype, pretransplant HCV genotyping of tissue donors would be beneficial. To our knowledge, donor HCV genotyping has never been reported. We retrieved archived frozen plasma samples for 17 previous organ donors through a local organ procurement organization. We performed HCV genotyping using the eSensor HCVg Direct Test (GenMark Diagnostics) and also by Sanger sequencing, for confirmation (Retrogen). In addition, viral loads were measured using the COBAS AmpliPrep/TaqMan system (Roche Diagnostics). We found that most of the samples (n = 14) were HCV Genotype 1a with the remainder being Genotype 2b (n = 1) or Genotype 3 (n = 2). All genotyping results were concordant with Sanger sequencing. The average HCV viral load in the sample group was ~ 1.6 million IU/mL (range: ~16 000 IU/mL to 7 million IU/mL). We demonstrate that viral RNA from organ donor plasma can be successfully genotyped for HCV. This ability suggests that transplantation of HCV+ kidneys into HCV-negative recipients, followed by genotype-guided antiviral therapy, could be feasible. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Determinants of vitamin D status in fair-skinned women of childbearing age at northern latitudes.

    Directory of Open Access Journals (Sweden)

    Linnea Hedlund

    Full Text Available BACKGROUND AND OBJECTIVE: Poor vitamin D status during pregnancy has been associated with unfavorable outcomes for mother and child. Thus, adequate vitamin D status in women of childbearing age may be important. The aim of this study is to investigate the determinants of 25-hydroxyvitamin D (25(OHD serum concentrations in women of childbearing age living in Sweden, at latitude 57-58° north. METHOD: Eighty four non-pregnant, non-lactating, healthy, fair-skinned women aged between 25-40 years were included. All subjects provided blood samples, four day food records and answered questionnaires about sun exposure and lifestyle. Total serum 25(OHD was analyzed using Roche Cobas® electrochemoluminiescent immunoassay. RESULTS: Mean 25(OHD was 65.8±19.9 nmol/l and 23% of the subjects had concentrations <50 nmol/l. Only 1% had concentrations <25 nmol/l. Determinants of 25(OHD concentrations were recent sunbed use, recent travel to southern latitude, season, estrogen contraceptive use and use of supplementary vitamin D (R(2 = 0.27. CONCLUSION: Every fifth woman had 25(OHD concentrations <50 nmol/l. About 30% of the variation in vitamin D status was explained by sun exposure, use of vitamin D supplements and use of estrogen contraceptives. Cutaneous vitamin D synthesis seems to be a major contributor to vitamin D status, even at northern latitudes. Thus, recommendations on safe UV-B exposure could be beneficial for vitamin D status.

  9. Correlation of Serum Cystatin C with Glomerular Filtration Rate in Patients Receiving Platinum-Based Chemotherapy

    Directory of Open Access Journals (Sweden)

    Ernesta Cavalcanti

    2016-01-01

    Full Text Available Objectives. Serum cystatin C seems to be an accurate marker of glomerular filtration rate (GFR compared to serum creatinine. The aim of this work was to explore the possibility of using serum cystatin C instead of serum creatinine to early predict renal failure in cancer patients who received platinum based chemotherapy. Design and Methods. Serum creatinine, serum cystatin C concentrations, and GFR were determined simultaneously in 52 cancer patients received carboplatin-based or cisplatin-based chemotherapy. Serum creatinine was assayed on Cobas C6000-Roche, serum cystatin C assay was performed on AIA 360-Tosoh, and GFR was determined in all patients, before the first cycle of chemotherapy and before the subsequent administrations. Results. In the overall series, for the prediction of a fall of GFR < 80 mL/min/1.73 m2, the AUC of the ROC curve for cystatin C was 0,667 and the best threshold was 1.135 mg/L (sensitivity 90.5%, specificity 61.1%. For a GFR fall < 60 mL/min/1.73 m2, the AUC of ROC curve for cystatin C was 74.3% and the best threshold was 1.415 mg/L (sensitivity 66.7%, specificity 73.2%. Conclusions. Baseline cystatin C values were not able to predict renal failure during subsequent treatment. In conclusion, serum cystatin C is not a reliable early marker to efficiently predict renal failure in patients receiving chemotherapy.

  10. The role of carboxyhemoglobin measured with CO-oximetry in the detection of hemolysis in newborns with ABO alloimmunization.

    Science.gov (United States)

    Lozar-Krivec, Jana; Bratanic, Borut; Paro-Panjan, Darja

    2016-01-01

    To evaluate carboxyhemoglobin (COHb) values measured with a CO-oximeter (Roche-cobas b 221) in jaundiced newborns with or without hemolysis and healthy controls in order to assess whether COHb measurement determined with a CO-oximeter could be used as an indicator of hemolysis in newborns with ABO alloimmunization. A total of 86 term newborn infants were prospectively studied. The study cohort consisted of three subgroups: 18 infants with ABO HDN, 21 infants with hyperbilirubinemia without hemolytic disease who required phototherapy, and 47 healthy controls. The COHb, bilirubin, and Hb levels were measured. The three subgroups did not differ significantly with respect to birth weight, gestational age, gender, Apgar score, or mode of delivery. The ABO HDN infants had significantly higher COHb values than the healthy controls (median 2.4% versus 1.3%, p < 0.0005) and the group with hyperbilirubinemia without hemolytic disease (median 2.4% versus 1.3%, p < 0.0005), although the infants with hyperbilirubinemia without hemolytic disease did not have significantly higher COHb values compared with the healthy controls. The cut-off value of 1.7% COHb had 72% sensitivity and 97% specificity for confirming hemolysis in ABO alloimmunization. Our data show that COHb values determined with CO-oximeters are higher in newborns with hemolysis than in those without hemolysis. COHb measured with CO-oximeters could be used to confirm hemolysis in infants with ABO alloimmunization.

  11. Evaluation of the Roche LightMix Gastro parasites multiplex PCR assay detecting Giardia duodenalis, Entamoeba histolytica, cryptosporidia, Dientamoeba fragilis, and Blastocystis hominis.

    Science.gov (United States)

    Friesen, J; Fuhrmann, J; Kietzmann, H; Tannich, E; Müller, M; Ignatius, R

    2018-03-23

    Multiplex PCR assays offer highly sensitive and specific tools for the detection of enteric pathogens. This prospective study aimed at comparing the novel Roche LightMix Modular Assay Gastro Parasites (LMAGP) detecting Giardia duodenalis, Entamoeba histolytica, Cryptosporidium spp., Blastocystishominis, and Dientamoebafragilis with routine laboratory procedures. Stool specimens (n = 1062 from 1009 patients) were consecutively examined by LMAGP, R-Biopharm Ridascreen enzyme immunoassays (EIAs) detecting G. duodenalis or E. histolytica/dispar, and microscopy of wet mounts. Discrepant results were analysed by in-house PCR. D. fragilis or B. hominis were detected by LMAGP in 131 (14.4%) and 179 (19.9%; 16 samples positive by microscopy; p PCR). G. duodenalis was detected by LMAGP, EIA, or microscopy in 20, 16, or 9 of 1039 stool samples, respectively; all four samples missed by EIA were confirmed by in-house PCR. In total, 938 stool samples were analysed for E. histolytica/dispar. Nine of ten EIA-positive samples were negative by LMAGP but positive by in-house PCR for E. dispar. One E. histolytica infection (positive by both LMAGP and in-house PCR) was missed by EIA and microscopy. Parasites only detected by microscopy included Enterobius vermicularis eggs (n = 3) and apathogenic amoebae (n = 27). The data call for routine use of multiplex PCR assays for the detection of enteric protozoan parasites in laboratory diagnostics. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  12. [Detection of RAS genes mutation using the Cobas® method in a private laboratory of pathology: Medical and economical study in comparison to a public platform of molecular biology of cancer].

    Science.gov (United States)

    Albertini, Anne-Flore; Raoux, Delphine; Neumann, Frédéric; Rossat, Stéphane; Tabet, Farid; Pedeutour, Florence; Duranton-Tanneur, Valérie; Kubiniek, Valérie; Vire, Olivier; Weinbreck, Nicolas

    In France, determination of the mutation status of RAS genes for predictive response to anti-EGFR targeted treatments is carried out by public platforms of molecular biology of cancer created by the French National Cancer Institute. This study aims to demonstrate the feasibility of these analyses by a private pathology laboratory (MEDIPATH) as per the requirements of accreditation. We retrospectively studied the mutation status of KRAS and NRAS genes in 163 cases of colorectal metastatic cancer using the Cobas ® technique. We compared our results to those prospectively obtained through pyrosequencing and allelic discrimination by the genetic laboratory of solid tumors at the Nice University Hospital (PACA-EST regional platform). The results of both series were identical: 98.7% positive correlation; negative correlation of 93.1%; overall correlation of 95.7% (Kappa=0.92). This study demonstrates the feasibility of molecular analysis in a private pathology laboratory. As this practice requires a high level of guarantee, its accreditation, according to the NF-EN-ISO15189 quality compliance French standard, is essential. Conducting molecular analysis in this context avoids the steps of routing the sample and the result between the pathology laboratory and the platform, which reduces the overall time of rendering the result. In conclusion, the transfer of some analysis from these platforms to private pathology laboratories would allow the platforms to be discharged from a part of routine testing and therefore concentrate their efforts to the development of new analyses constantly required to access personalized medicine. Copyright © 2017. Published by Elsevier Masson SAS.

  13. Utility of pooled urine specimens for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in men attending public sexually transmitted infection clinics in Mumbai, India, by PCR.

    Science.gov (United States)

    Lindan, Christina; Mathur, Meenakshi; Kumta, Sameer; Jerajani, Hermangi; Gogate, Alka; Schachter, Julius; Moncada, Jeanne

    2005-04-01

    Pooling urogenital specimens for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae by nucleic acid amplification tests is an attractive alternative to individual testing. As pooling can reduce the costs of testing as well as labor, it has been advocated for use in resource-poor settings. However, it has neither been widely adopted nor evaluated for use in developing countries. We evaluated the practical use of pooling first-catch urine (FCU) specimens for the detection of C. trachomatis and N. gonorrhoeae from 690 men in Mumbai, India, by PCR. FCU, urethral smears, and swabs were collected from men seen at two sexually transmitted infection (STI) clinics. All laboratory testing was done at the Lokmanya Tilak General Hospital. Gram stain smears and culture isolation for N. gonorrhoeae were performed. Each FCU was tested individually and in pools using the Roche Amplicor PCR for C. trachomatis and N. gonorrhoeae with an internal control for inhibition. Specimen pools consisted of aliquots from five consecutively processed FCUs combined into an amplification tube. An optical density reading of > or =0.20 indicated a pool for which subsequent testing of individual samples was required. Prevalence by PCR on single specimens was 2.2% (15/690) for C. trachomatis and 5.4% (37/690) for N. gonorrhoeae. Compared to individual FCU results, pooling for C. trachomatis and N. gonorrhoeae had an overall sensitivity of 96.1% (50/52). Specificity was 96.5% (83/86) in that three pools required single testing that failed to identify a positive specimen. Pooling missed two positive specimens, decreased the inhibition rate, and saved 50.3% of reagent costs. In this resource-limited setting, the use of pooling to detect C. trachomatis and N. gonorrhoeae by PCR proved to be a simple, accurate, and cost-effective procedure compared to individual testing.

  14. Indeterminate RIBA results were associated with the absence of hepatitis C virus RNA (HCV-RNA in blood donors

    Directory of Open Access Journals (Sweden)

    Felicidade Mota Pereira

    2014-01-01

    Full Text Available Introduction: Hepatitis C virus (HCV infection is diagnosed by the presence of antibodies and is supplemented by confirmatory testing methods, such as recombinant immunoblot assay (RIBA and HCV-RNA detection. This study aimed to evaluate the efficacy of RIBA testing to diagnose HCV infection in blood donors positive for anti-HCV antibodies. Methods: A total of 102 subjects positive for anti-HCV determined by enzyme-linked immunosorbent assay (ELISA at the Hematology and Hemotherapy Foundation of Bahia (HEMOBA were later assessed with new samples using the Abbott Architect anti-HCV test (Abbott Diagnostics, Wiesbaden, Germany, the RIBA III test (Chiron RIBA HCV 3.0 SIA, Chiron Corp., Emeryville, CA, USA, the polymerase chain reaction (PCR; COBAS® AMPLICOR HCV Roche Diagnostics Corp., Indianapolis, IN, USA and line probe assay (LiPA - Siemens, Tarrytown, NY, USA genotyping for HCV diagnosis. Results: Of these new samples, 38.2% (39/102 were positive, 57.8% (59/102 were negative and 3.9% (4/102 were indeterminate for anti-HCV; HCV-RNA was detected in 22.5% (23/102 of the samples. RIBA results were positive in 58.1% (25/43, negative in 9.3% (4/43 and indeterminate in 32.6% (14/43 of the samples. The prevailing genotypes were 1 (78.3%, 18/23, 3 (17.4%, 4/23 and 2 (4.3%, 1/23. All 14 samples with indeterminate RIBA results had undetectable viral loads (detection limit ≤50 IU/mL. Of these samples, 71.4% (10/14 were reevaluated six months later. Eighty percent (8/10 of these samples remained indeterminate by RIBA, and 20% (2/10 were negative. Conclusions: In this study, individuals with indeterminate RIBA results had no detectable HCV-RNA.

  15. Sensitivity and specificity of a new automated system for the detection of hepatitis B virus, hepatitis C virus, and human immunodeficiency virus nucleic acid in blood and plasma donations.

    Science.gov (United States)

    Galel, Susan A; Simon, Toby L; Williamson, Phillip C; AuBuchon, James P; Waxman, Dan A; Erickson, Yasuko; Bertuzis, Rasa; Duncan, John R; Malhotra, Khushbeer; Vaks, Jeffrey; Huynh, Nancy; Pate, Lisa Lee

    2018-03-01

    Use of nucleic acid testing (NAT) in donor infectious disease screening improves transfusion safety. Advances in NAT technology include improvements in assay sensitivity and system automation, and real-time viral target discrimination in multiplex assays. This article describes the sensitivity and specificity of cobas MPX, a multiplex assay for detection of human immunodeficiency virus (HIV)-1 Group M, HIV-2 and HIV-1 Group O RNA, HCV RNA, and HBV DNA, for use on the cobas 6800/8800 Systems. The specificity of cobas MPX was evaluated in samples from donors of blood and source plasma in the United States. Analytic sensitivity was determined with reference standards. Infectious window periods (WPs) before NAT detectability were calculated for current donor screening assays. The specificity of cobas MPX was 99.946% (99.883%-99.980%) in 11,203 blood donor samples tested individually (IDT), 100% (99.994%-100%) in 63,012 donor samples tested in pools of 6, and 99.994% (99.988%-99.998%) in 108,306 source plasma donations tested in pools of 96. Seven HCV NAT-yield donations and one seronegative occult HBV infection were detected. Ninety-five percent and 50% detection limits in plasma (IU/mL) were 25.7 and 3.8 for HIV-1M, 7.0 and 1.3 for HCV, and 1.4 and 0.3 for HBV. The HBV WP was 1 to 4 days shorter than other donor screening assays by IDT. cobas MPX demonstrated high specificity in blood and source plasma donations tested individually and in pools. High sensitivity, in particular for HBV, shortens the WP and may enhance detection of occult HBV. © 2017 The Authors Transfusion published by Wiley Periodicals, Inc. on behalf of AABB.

  16. PENGEMBANGAN MULTIMEDIA CERITA RAKYAT SEBAGAI PENUMBUHAN KARAKTER SISWA

    Directory of Open Access Journals (Sweden)

    Kusmayadi Kusmayadi

    2017-07-01

    Full Text Available This study was aimed to test feasibility multimedia appreciation folklore charged character education for student junior grade VII. The approach that was undertaken use qualitative and quantitative reseach. Subject pilot this reseach is one expert learning, one person media expert learning, practitioner, 5 (six student on trial small group, and 30 (thirty student on trial a large group. The trial court implemented in Junior High School 1 Praya Lombok Middle east. The data was undertaken through observation, charging chief, and guide documentation. Analysis quantitative data done by counting the percentage feasibility the product of the people of learning, media experts, practitioner, the results of the small group and results of the test a large group. The results of data qualitative presented in the form of exposure to. The research results show multimedia learning on all the step of experiment try is at the percentage very reasonable to be used as a media learning. Penelitian ini bertujuan untuk menguji kelayakan multimedia apresiasi cerita rakyat bermuatan pendidikan karakter untuk siswa SMP Kelas VII. Pendekatan yang dilakukan menggunakan kualitatif dan kuantitatif. Subjek uji coba penelitian ini adalah satu orang ahli pembelajaran, satu orang ahli media pembelajaran, satu orang praktisi, enam siswa pada uji coba kelompok kecil, dan tiga puluh siswa pada uji coba kelompok besar. Uji coba lapangan dilaksanakan di SMPN 1 Praya Timur Lombok Tengah. Pengambilan data dilakukan melalui observasi, pengisian angket, dan panduan dokumentasi. Analisis data kuantitatif dilakukan dengan menghitung persentase kelayakan produk dari ahli pembelajaran, ahli media, praktisi, hasil uji kelompok kecil dan hasil uji kelompok besar. Hasil data kualitatif disajikan dalam bentuk paparan. Hasil penelitian menunjukkan multimedia pembelajaran pada semua tahap uji coba berada pada persentase sangat layak untuk digunakan sebagai media pembelajaran.

  17. PERANGKAT LUNAK "DIGITAL SIGNAGE MANAGER"

    Directory of Open Access Journals (Sweden)

    Siti Rochimah

    2006-07-01

    Full Text Available Digital signage adalah suatu alat untuk menampilkan konten multimedia kepada umum. Digital signage pada umumnya terdiri dari dua komponen penting, yaitu manager dan player. Digital Signage Manager (DSM adalah suatu perangkat lunak yang mempunyai fungsi mengelola perangkat lunak Digital Signage Player (DSP. Pengelolaan ini menyangkut pengaturan dan pengiriman konten, pengaturan DSP, dan pengaturan konten yang ada di DSP. Pada penelitian ini telah dibangun sebuah perangkat lunak DSM, yang merupakan bentuk pengembangan dari perangkat lunak yang sebelumnya telah ada yaitu BZNP-100, yang tidak lain adalah perangkat lunak untuk mengelola Sony Network Player NSP-100. DSM dibangun dengan tujuan untuk melengkapi kekurangan dan menambah beberapa fitur tambahan yang belum ada pada perangkat lunak sebelumnya, seperti: mendukung material Flash, mengirim Content Delivery Disc (CDD, menjadwalkan playlist, dan mendukung dua layar. BZNP-100 dan Sony Network Player NSP-100 merupakan digital signage yang dibuat oleh perusahaan elektronik Sony Corporation pada tahun 2003.Uji coba perangkat lunak DSM ini dilakukan dengan menjalankan skenario uji coba berdasarkan fungsionalitas masing-masing fitur. Uji coba dilakukan pada masing-masing fitur antara lain: login, konfigurasi, pembuatan material, manajemen DSP, manajemen playlist, memainkan material dan playlist, dan manajemen remote material dan playlist. Hasil uji coba menunjukkan bahwa perangkat lunak DSM telah berfungsi sesuai dengan tujuan yang diharapkan.Kata kunci: Digital signage, Digital Signage Manager (DSM, Digital Signage Player (DSP, Content Delivery Disc (CDD, plasma TV,  LCD.

  18. PENGEMBANGAN MODEL LATIHAN KARATE KIDS PADA ANAK USIA SEKOLAH DASAR KELAS ATAS

    Directory of Open Access Journals (Sweden)

    Widha Srianto

    2014-09-01

    Full Text Available Penelitian ini bertujuan untuk menghasilkan model latihan karate kids pada anak usia sekolah dasar (SD kelas atas (10-12 tahun. Penelitian pengembangan ini dilakukan dengan mengadaptasi langkah-langkah penelitian sebagai berikut: (1 pengumpulan informasi di lapangan, (2 melakukan analisis terhadap informasi yang telah dikumpulkan, (3 mengembangkan produk awal, (4 validasi ahli dan revisi, (5 uji coba lapangan skala kecil dan revisi,  (6 uji coba lapangan skala besar dan revisi, dan (7 pembuatan produk final. Uji coba skala kecil dilakukan di klub Forki Kota Yogyakarta berjumlah 7 anak. Uji coba skala besar di klub Inkanas DIY berjumlah 16 anak. Instrumen pengumpulan data yang digunakan yaitu: (1 pedoman wawancara, (2 skala nilai, (3 pedoman observasi model, (4 pedoman observasi keefektifan model, dan (5 kuesioner untuk siswa. Teknik analisis data yang dilakukan yaitu analisis deskriptif kuantitatif dan analisis deskriptif kualitatif. Hasil penelitian ini berupa model latihan karate kids pada anak usia SD kelas atas (10-12 tahun yaitu: (1 model latihan maegeri, (2 model latihan gyaku tsuki, (3 model latihan mawashigeri, dan (4 model latihan oi tsuki. Dari hasil analisis data penilaian para ahli materi dan kuesioner anak, dapat ditarik kesimpulan bahwa model latihan karate kids pada anak usia SD kelas atas (10-12 tahun ini dinilai baik dan efektif. Kata kunci: model latihan, karate kids

  19. Avaliação do método imunoenzimático (ELISA para diagnóstico da infecção por Helicobacter pylori em crianças e adolescentes Evaluation of enzyme-linked immunosorbent assay for the diagnosis of Helicobacter pylori infection in children and adolescents

    Directory of Open Access Journals (Sweden)

    Aurea Portorreal

    2002-07-01

    Full Text Available RACIONAL: A infecção por Helicobacter pylori é reconhecida como a causa mais freqüente de gastrite crônica em adultos e crianças. Seu diagnóstico é realizado com métodos invasivos em fragmentos de mucosa gástrica obtidos com pinça endoscópica e os não-invasivos. O método imunoenzimático constitui exame simples, rápido e de baixo custo, apresentando alta sensibilidade em pacientes adultos. OBJETIVO: Avaliou-se o método ELISA prospectivamente em 111 crianças e adolescentes. MATERIAL E MÉTODOS: Utilizou-se o kit "Cobas Core II" (Roche. Considerou-se Helicobacter pylori positivo quando o teste rápido da urease e a histologia resultaram ambos positivos ou quando a cultura foi positiva, e Helicobacter pylori negativo quando todos os testes foram negativos. RESULTADOS: A idade dos 111 pacientes variou de 3 meses a 16 anos, (mediana = 9a 5m; média = 8a 7m ± 4.0. Infecção por Helicobacter pylori foi diagnosticada em 47,7% (53/111. A sensibilidade da sorologia foi de 83,0% e 86,0% e a especificidade foi de 70,6% e 71,0%, utilizando o ponto de corte de 7 U/mL e 5 U/mL, respectivamente. Em pacientes maiores de 10 anos de idade, a sensibilidade foi de 90,6% e 96,8% e a especificidade 71,0% e 61,9%, com ponto de corte de 7 U/mL e 5 U/mL, respectivamente. Quando foi utilizada somente a cultura positiva como padrão ouro e ponto de corte em 5 U/mL, a sensibilidade foi de 93,3%. CONCLUSÃO: O método ELISA apresentou boa sensibilidade em crianças maiores de 10 anos, utilizando o ponto de corte de 5 U/mL, porém a especificidade foi menor.BACKGROUND: Helicobacter pylori infection is recognized as the most frequent cause of chronic gastritis in adults and children. The diagnosis is accomplished with invasive methods in fragments of endoscopic gastric biopsies and non-invasive methods. The enzyme-linked immunosorbent assay constitutes a simple, fast exam and of low cost with high sensibility in adult patients. AIM: The purpose of this study

  20. Gyrotropy and Anisotropy of Rocks: Similarities and Differences Gyrotropie et anisotropie des roches : similitudes et différences

    Directory of Open Access Journals (Sweden)

    Chichinina T. I.

    2006-12-01

    Full Text Available The main features of wave propagation in gyrotropic media are compared with wave propagation in anisotropic media. The results of numerical modelling are presented for three typical seismic exploration models. The first two models are azimuthally anisotropic media (of orthorombic symmetry system, group 2m without and with gyration. The third model is a gyrotropic transversely isotropic medium with a vertical symmetry axis. The computations have been made for propagation of shear waves along the vertical symmetry axis. For sufficiently short wave paths (in our models less than 400 m the two-component (x, y seismograms are similar for all three models. For longer paths both signal shape and signal duration for the first and the third model differ noticeably. Some evidence (experimental data and a micromodel is given to show that the gyrotropy of rocks does exist or, at least, can exist. Les principales caractéristiques de la propagation des ondes dans les milieux gyrotropes sont comparées avec la propagation des ondes dans les milieux azimutalement anisotropes. Les résultats d'une modélisation numérique sont présentés pour trois modèles caractéristiques d'exploration sismique. Les deux premiers modèles sont des milieux anisotropes (de symétrie orthorhombique, groupe 2m avec et sans gyrotropie. Le troisième modèle est un milieu gyrotrope transverse isotrope avec un axe de symétrie vertical. Ces calculs ont été réalisés pour la propagation des ondes transversales le long de l'axe de symétrie vertical. Pour des trajets sismiques suffisamment courts (pour nos modèles, moins de 400 m, les sismogrammes à deux composantes (x, y sont similaires pour les trois modèles. Pour des trajets plus longs, la forme et la durée du signal diffèrent sensiblement pour les modèles 1 et 3. Ceci a pour but de montrer (à l'aide des données expérimentales et d'un micromodèle que la gyrotropie dans les roches existe, ou, tout au moins, peut

  1. BRAF mutation testing in solid tumors: a methodological comparison.

    Science.gov (United States)

    Weyant, Grace W; Wisotzkey, Jeffrey D; Benko, Floyd A; Donaldson, Keri J

    2014-09-01

    Solid tumor genotyping has become standard of care for the characterization of proto-oncogene mutational status, which has traditionally been accomplished with Sanger sequencing. However, companion diagnostic assays and comparable laboratory-developed tests are becoming increasingly popular, such as the cobas 4800 BRAF V600 Mutation Test and the INFINITI KRAS-BRAF assay, respectively. This study evaluates and validates the analytical performance of the INFINITI KRAS-BRAF assay and compares concordance of BRAF status with two reference assays, the cobas test and Sanger sequencing. DNA extraction from FFPE tissue specimens was performed followed by multiplex PCR amplification and fluorescent label incorporation using allele-specific primer extension. Hybridization to a microarray, signal detection, and analysis were then performed. The limits of detection were determined by testing dilutions of mutant BRAF alleles within wild-type background DNA, and accuracy was calculated based on these results. The INFINITI KRAS-BRAF assay produced 100% concordance with the cobas test and Sanger sequencing and had sensitivity equivalent to the cobas assay. The INFINITI assay is repeatable with at least 95% accuracy in the detection of mutant and wild-type BRAF alleles. These results confirm that the INFINITI KRAS-BRAF assay is comparable to traditional sequencing and the Food and Drug Administration-approved companion diagnostic assay for the detection of BRAF mutations. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  2. PENGEMBANGAN BUKU AJAR BIOLOGI SEL DENGAN PENDEKATAN BIOINFORMATIKA

    Directory of Open Access Journals (Sweden)

    Ardini Pangastuti

    2016-02-01

    Buku ajar merupakan buku panduan pembelajaran yang digunakan oleh siswa guna membantu mencapai tujuan pendidikan nasional. Pengembangan buku ajar merupakan salah satu cara yang dilakukan untuk memfasilitasi tercapainya indikator pembelajaran. Pengembangan buku ajar Biologi Sel dengan pendekatan Bioinformatika menggunakan model pengembangan Dick and Carey. Buku ajar yang dikembangkan divalidasi oleh ahli materi, ahli media pembelajaran, 15 mahasiswa uji coba perorangan, dan 15 mahasiswa uji coba kelompok sedang. Hasil validasi ahli materi menyatakan layak sebesar 84% dengan kategori baik. Hasil validasi ahli media pembelajaran menyatakan layak sebesar 82,4% dengan kategori baik.

  3. Analytical validation of Gentian NGAL particle-enhanced enhanced turbidimetric immunoassay (PETIA

    Directory of Open Access Journals (Sweden)

    Gian Luca Salvagno

    2017-08-01

    Full Text Available Objectives: This study was designed to validate the analytical performance of the new Gentian particle-enhanced enhanced turbidimetric immunoassay (PETIA for measuring neutrophil gelatinase-associated lipocalin (NGAL in serum samples. Design and methods: Analytical validation of the Gentian NGAL assay was carried out on a Roche Cobas c501 and was based on assessment of limit of blank (LOB, limit of detection (LOD, functional sensitivity, imprecision, linearity and concordance with the BioPorto NGAL test. Results: The LOB and LOD of Gentian NGAL were found to be 3.8 ng/mL and 6.3 ng/mL, respectively. An analytical coefficient of variation (CV of 20% corresponded to a NGAL value of 10 ng/mL. The intra-assay and inter-assay imprecision (CV was between 0.4 and 5.2% and 0.6 and 7.1% and the total imprecision (CV was 3.7%. The linearity was optimal at NGAL concentrations between 37 and 1420 ng/mL (r=1.00; p<0.001. An excellent correlation was observed between values measured with Gentian NGAL and BioPorto NGAL in 74 routine serum samples (r=0.993. The mean percentage bias of the Gentian assay versus the Bioporto assay was +3.1% (95% CI, +1.6% to +4.5%. Conclusions: These results show that Gentian NGAL may be a viable option to other commercial immunoassays for both routine and urgent assessment of serum NGAL. Keywords: Neutrophil gelatinase-associated lipocalin, NGAL, Analytical validation, Acute kidney injury

  4. Ethamsylate (Dicynone) interference in determination of serum creatinine, uric acid, triglycerides, and cholesterol in assays involving the Trinder reaction; in vivo and in vitro.

    Science.gov (United States)

    Dastych, Milan; Wiewiorka, Ondrej; Benovská, Miroslava

    2014-01-01

    The aim of our research was the quantification of interfering properties of the haemostatic drug Dicynone (ethamsylate) in serum creatinine, uric acid, cholesterol, and triglyceride assays using the Trinder reaction. Blood from patients was collected before and 15 minutes after administration of 500 mg Dicynone dose i.v. and the above mentioned analytes were quantified using Roche assays (Cobas 8000). In our in vitro experiment, we measured concentrations of the analytes in pooled serum aliquots with final concentrations of Dicynone additions 0, 30, 60, 150, and 300 mg/L. Aliquots with 60 mg/L Dicynone were also measured at 2, 6, and 8 hours after initial measurement when stored in 22 degrees C and 4 degrees C for comparison. Concentrations of the measured analytes in samples from patients administered with a 500 mg dose of Dicynone were lower in all cases (n = 10) when compared to values in samples taken immediately before treatment. The in vitro samples showed that considerable negative interference occurred even with the low concentrations of Dicynone additions (30 and 60 mg/L), showing the strongest negative interference in creatinine values, followed by uric acid, triglycerides, and cholesterol. Using in vitro samples, we showed strong time and temperature dependence on Dicynone interference. We found and proved significant negative interference of the drug Dicynone (ethamsylate) in the clinical analysis of blood using in vivo and in vitro experiments. Furthermore, we observed a change of this effect in serum matrix over time and at different storage temperatures.

  5. Effects of different centrifugation conditions on clinical chemistry and Immunology test results.

    Science.gov (United States)

    Minder, Elisabeth I; Schibli, Adrian; Mahrer, Dagmar; Nesic, Predrag; Plüer, Kathrin

    2011-05-10

    The effect of centrifugation time of heparinized blood samples on clinical chemistry and immunology results has rarely been studied. WHO guideline proposed a 15 min centrifugation time without citing any scientific publications. The centrifugation time has a considerable impact on the turn-around-time. We investigated 74 parameters in samples from 44 patients on a Roche Cobas 6000 system, to see whether there was a statistical significant difference in the test results among specimens centrifuged at 2180 g for 15 min, at 2180 g for 10 min or at 1870 g for 7 min, respectively. Two tubes with different plasma separators (both Greiner Bio-One) were used for each centrifugation condition. Statistical comparisons were made by Deming fit. Tubes with different separators showed identical results in all parameters. Likewise, excellent correlations were found among tubes to which different centrifugation conditions were applied. Fifty percent of the slopes lay between 0.99 and 1.01. Only 3.6 percent of the statistical tests results fell outside the significance level of p < 0.05, which was less than the expected 5%. This suggests that the outliers are the result of random variation and the large number of statistical tests performed. Further, we found that our data are sufficient not to miss a biased test (beta error) with a probability of 0.10 to 0.05 in most parameters. A centrifugation time of either 7 or 10 min provided identical test results compared to the time of 15 min as proposed by WHO under the conditions used in our study.

  6. Nucleic acid amplification test for detection of west nile virus infection in pakistani blood donors

    International Nuclear Information System (INIS)

    Niazi, S.K.; Alam, M.

    2017-01-01

    Background: The study was planned to determine the presence of West Nile Virus (WNV) infection in Pakistani blood donors, using Nucleic Acid Amplification Test (NAT). Methods: The blood donors for study were selected on the basis of the standard questionnaire and routine screening results. Six donors were pooled using an automated pipettor and NAT for WNV was performed on Roche Cobas s 201 NAT system. The reactive pools were resolved in Individual Donation-NAT (ID-NAT) format and a sample from FFP bags of reactive donations was retrieved. NAT was again performed on retrieved plasma bag (RPB) sample to confirm the reactive donations. The donors were also recalled and interviewed about history of illness related to recent WNV infection. Results: After serological screening of 1929 donors during the study period, 1860 donors were selected for NAT test for WNV detection. The mean age of the donors was 28±8.77 (range: 18–57 years). 1847 (99.3%) donors were male and 13 (0.7%) were female. NAT for WNV identified six initially reactive pools (0.32%). On follow-up testing with RPB samples, 4 donors (0.21%) were found confirmed reactive for WNV RNA (NAT yield of 1 in 465 blood donors). Conclusion: WNV is a threat to safety of blood products in Pakistan. A screening strategy can be implemented after a large-scale study and financial considerations. One of the reduced cost screening strategies is seasonal screening of blood donors for WNV, with pooling of samples. (author)

  7. RAS screening in colorectal cancer: a comprehensive analysis of the results from the UK NEQAS colorectal cancer external quality assurance schemes (2009-2016).

    Science.gov (United States)

    Richman, Susan D; Fairley, Jennifer; Butler, Rachel; Deans, Zandra C

    2017-12-01

    Evidence strongly indicates that extended RAS testing should be undertaken in mCRC patients, prior to prescribing anti-EGFR therapies. With more laboratories implementing testing, the requirement for External Quality Assurance schemes increases, thus ensuring high standards of molecular analysis. Data was analysed from 15 United Kingdom National External Quality Assessment Service (UK NEQAS) for Molecular Genetics Colorectal cancer external quality assurance (EQA) schemes, delivered between 2009 and 2016. Laboratories were provided annually with nine colorectal tumour samples for genotyping. Information on methodology and extent of testing coverage was requested, and scores given for genotyping, interpretation and clerical accuracy. There has been a sixfold increase in laboratory participation (18 in 2009 to 108 in 2016). For RAS genotyping, fewer laboratories now use Roche cobas®, pyrosequencing and Sanger sequencing, with more moving to next generation sequencing (NGS). NGS is the most commonly employed technology for BRAF and PIK3CA mutation screening. KRAS genotyping errors were seen in ≤10% laboratories, until the 2014-2015 scheme, when there was an increase to 16.7%, corresponding to a large increase in scheme participants. NRAS genotyping errors peaked at 25.6% in the first 2015-2016 scheme but subsequently dropped to below 5%. Interpretation and clerical accuracy scores have been consistently good throughout. Within this EQA scheme, we have observed that the quality of molecular analysis for colorectal cancer has continued to improve, despite changes in the required targets, the volume of testing and the technologies employed. It is reassuring to know that laboratories clearly recognise the importance of participating in EQA schemes.

  8. Multicenter Evaluation of Cystatin C Measurement after Assay Standardization.

    Science.gov (United States)

    Bargnoux, Anne-Sophie; Piéroni, Laurence; Cristol, Jean-Paul; Kuster, Nils; Delanaye, Pierre; Carlier, Marie-Christine; Fellahi, Soraya; Boutten, Anne; Lombard, Christine; González-Antuña, Ana; Delatour, Vincent; Cavalier, Etienne

    2017-04-01

    Since 2010, a certified reference material ERM-DA471/IFCC has been available for cystatin C (CysC). This study aimed to assess the sources of uncertainty in results for clinical samples measured using standardized assays. This evaluation was performed in 2015 and involved 7 clinical laboratories located in France and Belgium. CysC was measured in a panel of 4 serum pools using 8 automated assays and a candidate isotope dilution mass spectrometry reference measurement procedure. Sources of uncertainty (imprecision and bias) were evaluated to calculate the relative expanded combined uncertainty for each CysC assay. Uncertainty was judged against the performance specifications derived from the biological variation model. Only Siemens reagents on the Siemens systems and, to a lesser extent, DiaSys reagents on the Cobas system, provided results that met the minimum performance criterion calculated according to the intraindividual and interindividual biological variations. Although the imprecision was acceptable for almost all assays, an increase in the bias with concentration was observed for Gentian reagents, and unacceptably high biases were observed for Abbott and Roche reagents on their own systems. This comprehensive picture of the market situation since the release of ERM-DA471/IFCC shows that bias remains the major component of the combined uncertainty because of possible problems associated with the implementation of traceability. Although some manufacturers have clearly improved their calibration protocols relative to ERM-DA471, most of them failed to meet the criteria for acceptable CysC measurements. © 2016 American Association for Clinical Chemistry.

  9. Performance evaluation of LUMIPULSE G1200 autoimmunoanalyzer for the detection of serum hepatitis B virus markers.

    Science.gov (United States)

    Choi, Seung Jun; Park, Yongjung; Lee, Eun Young; Kim, Sinyoung; Kim, Hyon-Suk

    2013-05-01

    We evaluated recently introduced automated immunoassay analyzer LUMIPULSE G1200 (Fujirebio, Inc., Tokyo, Japan) for detecting serologic hepatitis B virus (HBV) markers by comparison with the results by ARCHITECT i4000SR (Abbott, Abbott Park, IL). Precision performance was evaluated over 20 days. HBV surface antigen (HBsAg), HBV e antigen (HBeAg), antibodies to HBV core antigen (anti-HBc), antibodies to HBeAg (anti-HBe), and antibodies to HBsAg (anti-HBs) in a total of 1,000 serum samples were assessed by the two analyzers. Discrepant results were retested by COBAS e411 (Roche Diagnostics, Mannheim, Germany). LUMIPULSE showed excellent precision performance of total imprecision less than 3.5% coefficient of variation. The qualitative results between the two analyzers were agreed with each other in 92.0-99.8% of the specimens according to the different HBV markers. The degrees of reactions for HBeAg were moderately correlated between the two analyzers (r = 0.60), and those of other HBV markers were well correlated (r = 0.80 or greater). However, there were 183 discrepancies among 1,000 cases, and most of them showed degree of reaction around the cutoff values. LUMIPULSE G1200 showed well-concordant results with ARCITHECT for hepatitis B serologic tests. However, results near the cutoff values would need to be retested with other immunoassay or molecular methods, when the serological profiles of HBV markers are unusual or are not correlated to the clinical conditions of the patient, due to discrepancies between the immunoassay analyzers. © 2013 Wiley Periodicals, Inc.

  10. The Effects of Sodium Bicarbonate and Sodium Citrate on Blood pH, HCO3-, Lactate Metabolism and Time to Exhaustion

    Directory of Open Access Journals (Sweden)

    Soetanto Hartono

    2017-02-01

    Full Text Available The purpose of this study was to compare the effects of sodium bicarbonate and sodium citrate in increasing lactate concentration, blood pH, HCO3-, and time to exhaustion. Increased time to exhaustion is an advantage since the athletes can do more anaerobic work. Exhaustion could be delayed by increasing HCO3- to catch H+ produced by lactate metabolism to form H2O and CO2. The design of this research was randomized pretest posttest control group design. Thirty badminton student players were randomly selected and randomly assigned to three groups. The first group (the control group was given placebo, NaCl .9 g/dl, the second group was given sodium bicarbonate 300 mg/kg in 500 ml aqua, and the third group was given sodium citrate 300 mg/kg in 500 ml aqua. Blood pH and bicarbonate ion (HCO3- were measured through Opti Medical Blood gas Analyzer. Lactate was measured by Cobas Roche lactate Analyzer. Data was analyzed using Manova with .05 significant level. Blood pH of the groups taking sodium bicarbonate and sodium citrate were higher significantly against control group (p.05. Sodium bicarbonate is better than sodium citrate, although both were better than control (p<.05. Sodium bicarbonate is better than sodium citrate in increasing blood pH and time to exhaustion. The disadvantage of using sodium bicarbonate is that it can cause gastrointestinal problem and headache, so it is not advisable to be used by athletes who have the symptoms.

  11. Validation of a new HPV self-sampling device for cervical cancer screening: The Cervical and Self-Sample In Screening (CASSIS) study.

    Science.gov (United States)

    El-Zein, Mariam; Bouten, Sheila; Louvanto, Karolina; Gilbert, Lucy; Gotlieb, Walter; Hemmings, Robert; Behr, Marcel A; Franco, Eduardo L; Liang, Victoria; Martins, Claudia; Duarte, Silvy; Sarban, Natalia; Geddes, Patricia; Massa, Ana; Samios, Kathrin; Aboufadl, Siham; Verdon, Sophie; Pereria, Cynthia; Lacroix, Isabelle

    2018-04-17

    We compared the self-sampling performance of the newly designed HerSwab™ device with a physician-collected cervical sample and another self-sample using the cobas® PCR Female swab for the detection of cervical intraepithelial neoplasia (CIN) and cancer. Women referred for colposcopy at McGill University affiliated hospital clinics collected two consecutive self-samples, one with HerSwab™ and one with cobas® swab, after receiving instructions. The order of sampling was randomized. The colposcopist then collected a cervical sample and conducted a colposcopic examination. Samples were tested for human papillomavirus (HPV) DNA. Sensitivity and specificity to detect CIN2+ and respective 95% confidence intervals (CI) were calculated to compare sampling approaches. The HPV testing agreement between samples was measured using the Kappa statistic. Of 1217 women enrolled, 1076 had complete results for HPV and cytology; 148 (13.8%) had CIN1, 147 (13.7%) had CIN2/3, and 5 (0.5%) had cancer. There was very good agreement between methods for HPV detection (HerSwab™ versus physician: kappa=0.84; cobas® swabs versus physician: kappa=0.81; HerSwab™ versus cobas® swabs: kappa=0.87). The sensitivity of HPV detection for CIN2+ was 87.6% (95%CI: 79.8-93.2) with self-sampling using HerSwab™, 88.6% (95%CI: 80.9-94.0) with self-sampling using the cobas® swab, and 92.4% (95%CI: 85.5-96.7) with physician sampling. Corresponding estimates of specificity were 58.1% (95%CI: 54.1-62.1), 55.0% (95%CI: 50.9-59.0) and 58.7% (95%CI: 54.6-62.6). Cytology (ASC-US or more severe) done on the physician-collected specimen was 80.2% (95%CI: 70.8-87.6) sensitive and 61.4% (95%CI: 57.2-65.5) specific for CIN2+. The HerSwab™ had good agreement with physician sampling in detecting HPV, and adequate performance in detecting high-grade lesions among women referred to colposcopy for abnormal cytology. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. PENGEMBANGAN MULTIMEDIA PEMBELAJARAN PATISERI UNTUK SISWA TINGKAT XI SMK

    Directory of Open Access Journals (Sweden)

    Tri Sunarmi

    2015-02-01

    Full Text Available Penelitian ini bertujuan untuk: 1 mengembangkan multimedia pembelajaran patiseri pada standar kompetensi mengolah kue pastry kontinental untuk siswa tingkat XI SMK yang layak dari aspek pembelajaran, materi, dan media; 2 mengetahui keefektifan multimedia pembelajaran patiseri yang dikembangan terhadap penguasaan kompetensi belajar mengolah kue pastry kontinental dilihat dari peningkatan skor tes hasil belajar. Jenis penelitian ini adalah penelitian dan pengembangan. Subyek penelitian adalah 36 siswa, untuk uji coba kelompok kecil dan uji coba lapangan. Validasi produk dilakukan oleh ahli materi dan ahli media. Selanjutnya data dianalisis dengan teknik analisis deskriptif.Hasil penilaian ahli materi dan ahli media menunjukkan bahwa kualitas multimedia “baik”. Penilaian siswa pada uji coba lapangan mengenai kualitas multimedia dari aspek pembelajaran,aspek materi dan aspek media “sangat baik“, dengan rerata skor dari ketiga aspek 4,49. Hasil pretes menunjukkan rerata sebesar 63,15 sedangkan rerata pada posttes sebesar 89,07. N-gain sebesar 0,72 termasuk kategori “tinggi”. Kesimpulannya: multimedia pembelajaran patiseri hasil pengembangan layak dignakan untuk media pembelajaran dan efektif untuk meningkatkan hasil belajar siswa.

  13. Low sensitivity of polymerase chain reaction for diagnosis of tuberculous meningitis in southeastern Brazil Baixa sensibilidade da reação em cadeia da polimerase para o diagnóstico de meningite tuberculosa no sudeste do Brasil

    Directory of Open Access Journals (Sweden)

    Vânia Maria Sabadoto Brienze

    2001-01-01

    Full Text Available Two polymerase chain reaction (PCR protocols showed low sensitivity (36% and 53% for TB AMPLICOR and MPB64 nested PCR, respectively, when compared with classic microbiological methods (73% and 54% for Ziehl-Neelsen staining and culture, respectively, in the diagnosis of tuberculous meningitis in 91 patients in southeastern Brazil. Only three PCR-positive, microbiologically negative patients were found. Analysis of sequential cerebrospinal fluid samples by nested PCR detected Mycobacterium tuberculosis DNA up to 29 days after the introduction of antituberculosis chemotherapy.Dois protocolos de reação em cadeia da polimerase (PCR apresentaram baixa sensibilidade (36% e 53%, respectivamente, para TB AMPLICOR e PCR aninhado baseado no gene MPB64, quando comparados aos métodos microbiológicos clássicos (73% e 54% respectivamente para baciloscopia e cultura, no diagnóstico de meningite tuberculosa em 91 pacientes do sudeste do Brasil. Somente três pacientes apresentaram PCR positiva e microbiologia negativa. A análise de amostras seqüenciais de líquor com a PCR aninhada detectou DNA de Mycobacterium tuberculosis até 29 dias após a introdução de tratamento.

  14. Quantification of intrahepatic total HBV DNA in liver biopsies of HBV-infected patients by a modified version of COBAS® Ampliprep/COBAS®TaqMan HBV test v2.0.

    Science.gov (United States)

    Salpini, Romina; Piermatteo, Lorenzo; Gill, Upkar; Battisti, Arianna; Stazi, Francesca; Guenci, Tania; Giannella, Sara; Serafini, Valentina; Kennedy, Patrick T F; Perno, Carlo Federico; Svicher, Valentina; Ciotti, Marco

    2017-08-01

    Intrahepatic total HBV DNA (it-HBV DNA) level might reflect the size of virus reservoir and correlate with the histological status of the liver. To quantitate it-HBV DNA in a series of 70 liver biopsies obtained from hepatitis B chronic patients, a modified version of the COBAS ® Ampliprep/COBAS ® TaqMan HBV test v2.0 was used for this purpose. The linearity and reproducibility of the modified protocol was tested by quantifying serial dilutions of a full-length HBV containing plasmid and it-HBV DNA from a reference patient. A good linear trend between the expected values and those generated by the assay was observed at different concentrations of both plasmid and reference patient (R 2  = 0.994 and 0.962, respectively). Differences between the values obtained in two independent runs were ≤0.3 log IU for the plasmid and ≤0.6 log IU/mg for the reference patient, showing a high inter-run reproducibility. In the 70 liver biopsies, it-HBV DNA level ranged from 1.4 to 5.4 log IU/mg, with a good linearity and reproducibility between the values obtained in two runs [R 2  = 0.981; median (IQR) difference of it-HBV DNA 0.05 (0.02-0.09) IU/mg]. The modified COBAS ® Ampliprep/COBAS ® TaqMan HBV test v2.0 allows an accurate quantitation of it-HBV DNA. Its determination may have prognostic value and may be a useful tool for the new therapeutic strategies aimed at eradicating the HBV infection.

  15. Evaluation of three methods for hemoglobin measurement in a blood donor setting

    Directory of Open Access Journals (Sweden)

    Jacob Rosenblit

    1999-05-01

    Full Text Available CONTEXT: The hemoglobin (Hb level is the most-used parameter for screening blood donors for the presence of anemia, one of the most-used methods for measuring Hb levels is based on photometric detection of cyanmetahemoglobin, as an alternative to this technology, HemoCue has developed a photometric method based on the determination of azide metahemoglobin. OBJECTIVE: To evaluate the performance of three methods for hemoglobin (Hb determination in a blood bank setting. DESIGN: Prospective study utilizing blood samples to compare methods for Hb determination. SETTING: Hemotherapy Service of the Hospital Israelita Albert Einstein, a private institution in the tertiary health care system. SAMPLE: Serial blood samples were collected from 259 individuals during the period from March to June 1996. MAIN MEASUREMENTS: Test performances and their comparisons were assessed by the analysis of coefficients of variation (CV, linear regression and mean differences. RESULTS: The CV for the three methods were: Coulter 0.68%, Cobas 0.82% and HemoCue 0.69%. There was no difference between the mean Hb determination for the three methods (p>0.05. The Coulter and Cobas methods showed the best agreement and the HemoCue method gave a lower Hb determination when compared to both the Coulter and Cobas methods. However, pairs of methods involving the HemoCue seem to have narrower limits of agreement (± 0.78 and ± 1.02 than the Coulter and Cobas combination (± 1.13. CONCLUSION: The three methods provide good agreement for hemoglobin determination.

  16. Study methods for the drillings around the underground nuclear explosions in the Sahara. Part 1. study of rock samples; Methodes d'etude des forages realises autour des explosions nucleaires souterraines au Sahara. Premiere partie: etude des echantillons de roche

    Energy Technology Data Exchange (ETDEWEB)

    Derlich, S [Commissariat a l' Energie Atomique, Bruyers-le-Chatel (France). Centre d' Etudes

    1969-07-01

    An examination of the mechanical effects produced on rocks by an underground nuclear explosion calls for the use of particular means of exploration which are described in this report, special attention being paid to the equipment used in connection with the French nuclear tests in the Sahara. The drilling methods used (rotary and turbo-drilling) are adapted to the particular conditions of the sampling programme, to the radioactivity and to the temperature in the region of the explosion. A study of the samples makes it possible to obtain the new characteristics of the rock and to assess the chemical and mechanical transformations which it has undergone. An examination of the core obtained from the drilling, together with a knowledge of the drilling parameters (depth of the probe, sample recovery, etc...), makes it possible to study the extent and the characteristics of the zones which have been damaged to different degrees according to their distance from the zero point: cavity, strongly powdered zone, fractured zone, chimney, zones containing high stresses leading to a particular type of fracture of the cores. The problems connected with the interpretation of the results are also presented. (author) [French] L'examen des effets mecaniques provoques par une explosion nucleaire souterraine sur la roche necessite la mise en oeuvre de moyens d'exploration particuliers dont l'expose fait l'objet de ce rapport, essentiellement pour les moyens utilises autour des essais nucleaires francais au Sahara. Les methodes de forage (rotary et turboforage) sont adaptees aux conditions particulieres dues au programme d'echantillonnage, a la radioactivite et a la temperature regnant a proximite du point de tir. L'etude des echantillons permet la determination des nouveaux caracteres de la roche et de ses transformations chimique et mecanique. L'examen des carottes et l'utilisation des parametres de forage (cotes sondeurs, recuperation des echantillons, etc...) permettent d'etudier l

  17. Comparison of three human papillomavirus DNA assays and one mRNA assay in women with abnormal cytology

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Lynge, Elsebeth; Ejegod, Ditte

    2014-01-01

    no follow-up, 232 (63%) had cancer. The sensitivity for ≥CIN3 was 95% (95% CI: 88-99) for HC2, 94% (95% CI: 87-98) for cobas, 93% (95% CI: 85-97) for CLART, and 87% (95% CI: 78-93) for APTIMA. In women of age above 30 years......, the sensitivities were 98% (95% CI: 87-100), 93% (95% CI: 80-98), 90% (95% CI: 77-97), and 93% (95% CI: 80-98), respectively. One woman with cervical cancer tested negative on CLART and one on cobas; HC2 and APTIMA were positive in all three cancer cases. The specificity for

  18. Performance verification and comparison of TianLong automatic hypersensitive hepatitis B virus DNA quantification system with Roche CAP/CTM system.

    Science.gov (United States)

    Li, Ming; Chen, Lin; Liu, Li-Ming; Li, Yong-Li; Li, Bo-An; Li, Bo; Mao, Yuan-Li; Xia, Li-Fang; Wang, Tong; Liu, Ya-Nan; Li, Zheng; Guo, Tong-Sheng

    2017-10-07

    To investigate and compare the analytical and clinical performance of TianLong automatic hypersensitive hepatitis B virus (HBV) DNA quantification system and Roche CAP/CTM system. Two hundred blood samples for HBV DNA testing, HBV-DNA negative samples and high-titer HBV-DNA mixture samples were collected and prepared. National standard materials for serum HBV and a worldwide HBV DNA panel were employed for performance verification. The analytical performance, such as limit of detection, limit of quantification, accuracy, precision, reproducibility, linearity, genotype coverage and cross-contamination, was determined using the TianLong automatic hypersensitive HBV DNA quantification system (TL system). Correlation and Bland-Altman plot analyses were carried out to compare the clinical performance of the TL system assay and the CAP/CTM system. The detection limit of the TL system was 10 IU/mL, and its limit of quantification was 30 IU/mL. The differences between the expected and tested concentrations of the national standards were less than ± 0.4 Log 10 IU/mL, which showed high accuracy of the system. Results of the precision, reproducibility and linearity tests showed that the multiple test coefficient of variation (CV) of the same sample was less than 5% for 10 2 -10 6 IU/mL; and for 30-10 8 IU/mL, the linear correlation coefficient r 2 = 0.99. The TL system detected HBV DNA (A-H) genotypes and there was no cross-contamination during the "checkerboard" test. When compared with the CAP/CTM assay, the two assays showed 100% consistency in both negative and positive sample results (15 negative samples and 185 positive samples). No statistical differences between the two assays in the HBV DNA quantification values were observed ( P > 0.05). Correlation analysis indicated a significant correlation between the two assays, r 2 = 0.9774. The Bland-Altman plot analysis showed that 98.9% of the positive data were within the 95% acceptable range, and the maximum difference

  19. Analysis of Hepatitis C Virus NS5A Region in Patients with Cirrhosis Using an Ultra-Deep Pyrosequencing Method.

    Science.gov (United States)

    Keskin, Fahriye; Ciftci, Sevgi; Akyuz, Filiz; Abaci, Neslihan; Cakiris, Aris; Akyuz, Umit; Demir, Kadir; Besisik, Fatih; Ustek, Duran; Kaymakoglu, Sabahattin

    2017-09-01

    HCV (Hepatitis C Virus) is genetically more diverse than HBV and HIV (Human Immunodeficiency Virus) and exists as quasispecies within infected individuals. This is due to the lack of efficient proofreading of the viral RNA-dependent RNA polymerase. Consequently, quasispecies emerge depending on the mutation rate of the viral polymerase, which may display a high level of genetic variability in a population. In infected individuals, HCV replicates and circulates as quasispecies composed of a complex mixture of different but closely related genomes that undergoes continuous change due to competitive selection and cooperation between arising mutants. The aim of this study is to investigate mutations in the NS5A region as a whole, including ISDR, PKRBD, IRRDR, and V3 of HCV genotype 1b cirrhosis patients being naive and nonresponders, treated with IFN (interferon) + ribavirin (RBN) by using an ultra-deep pyrosequencing method (UDPS). During the study, five patients (four females, and one male, mean age 59.8 ± 11 years) with HCV related cirrhosis were analyzed. Three patients received IFN + RBN for six months, but two patients did not receive any therapy. HCV-RNA concentrations in patients' sera were determined using a COBAS AMPLICOR HCV MONITOR Test, Version 2.0. Genotyping was performed by using a commercial reverse hybridization method, Line Probe Assay. The quasispecies for the NS5A region were investigated using UDPS. All five patients were HCV genotype 1b (Mean Child-Pugh score 7.2 ± 1.9, 2 pts Child A, 2 pts Child B, and one pt Child C) but only one patient had hepatocellular carcinoma (HCC). A total of 19 different mutations were detected in each of the five patients (ranging from 3 to 6 mutations per patient). In all five patients, several mutations in the ISDR and PKR-BD regions were detected. On the other hand, mutations in the V3 and IRRDR regions were only detected in one patient. UDPS is a new sequencing technology and a very sensitive method in detection

  20. Alteration hydrothermale et deformation ductile des roches volcaniques acides associees au gisement sulfure de draa sfar (Jebilet Centrales, Maroc

    Directory of Open Access Journals (Sweden)

    Zinbi, Y.

    2005-12-01

    Full Text Available The volcanics and volcanoclastic rocks of Draa Sfar (Central Jebilet, Moroccan hercynian belt are affected by ductile stress and hydrothermal alteration accompanied by a weak degree of metamorphism (greenschist facies. Some N-S oriented shearing zones, affect locally these formations while being the site of an important hydrothermal activity. The consequences of these transformations from a non to slightly- deformed rhyodacite, show that through these ductile shearing zones: (1 the mineralogical assemblage of hydrothermal alteration is essentially formed by chlorite, sericite, quartz and magnetite; (2 the gradual increase of the alteration indexes is accompanied by the destruction of the phenocrists and the recrystallization of the matrix by phyllosilicates and quartz; (3 the progressive transfer of material is more intense in the more deformed zones where the values of Ti, Al and Zr remain constant. These shearing zones played a very important role in the circulation of fluids and the transformation of the rhyodacite of Draa Sfar.Les roches volcaniques et volcanoclastiques de Draa Sfar (Jebilet centrales, Maroc hercynien sont affectées par une déformation ductile accompagnée d’un métamorphisme de faible degré (faciès schistes verts et d’une altération hydrothermale. Des zones de cisaillement de direction N-S, ont affecté localement ces formations tout en étant vecteurs d’une importante activité hydrothermale. Le suivi de ces transformations à partir de la rhyodacite non ou peu déformée, montre qu’à travers ces zones de cisaillements ductiles : (1 l’assemblage minéralogique d’altération hydrothermale est formé essentiellement de chlorite, de séricite, de quartz et de magnétite ; (2 l’augmentation graduelle des indices d’altération s’exprime par la destruction des phénocristaux au profit d’une matrice recristallisée en phyllosilicates et quartz ; (3 le transfert progressif de la matière est plus intense

  1. Pengembangan Instrumen Evaluasi Budi Pekerti Siswa SMU Negeri di Kabupaten Bantul

    Directory of Open Access Journals (Sweden)

    Esti Setiawati

    2014-07-01

    Full Text Available Penelitian ini bertujuan untuk mengembangkan instrumen evaluasi budi pekerti siswa SMU Negeri. Untuk itu perlu dirumuskan langkah-langkah pengembangan instrumen dan menyelidiki karakteristik instrumen tersebut. Subjek dalam penelitian ini adalah seluruh siswa SMU Negeri di Kabupaten Bantul. Penentuan banyaknya sampel dilakukan dengan teknik Purposive sampling sesuai dengan tujuan pengembangan. Instrumen penelitian ini adalah inventory Data dianalisis dengan analisis faktor. Hasil analisis data uji coba pengembangan Instrumen adalah: 1 Uji coba pertama dengan 85 butir, menunjukkan angka KMO and bartllets test sebesar 0,644 dengan p < 0,05. Setelah butir-butir tersebut dianalisis sejumlah, terdapat 11 butir yang tidak layak analisis yaitu butir 1, 2, 3, 5, 7, 8, 9, 10, 14, 32, dan butir 77 karena angka MSA < 0,5. Hasil pengujian ulang dengan 74 &117 butir menunjukkan angka KMO and Bartllets test sebesar 0,761 dengan p < 0,05, berarti mengalami kenaikan sebesar 0,117. Angka kumulatif muatan faktor sebesar 41,351 % dan nilai reliabilitas instrumen sebesar 0, 9656 2 Uji coba kedua dengan 85 butir hasil perbaikan instrumen uji coba pertama, menunjukkan angka KMO and Bartllets test sebesar 0,874 dengan p < 0,05. Setelah butir-butir tersebut dikenakan sejumlah pengujian, terdapat 1 butir yang tidak layak analisis yaitu butir 11 karena angka MSA < 0,5 hasil pengujian ulang dengan 84 butir menunjukkan angka KMO and Bartllets test sebesar 0,876 dengan P < 0,05, yang berarti mengalami kenaikan sebesar 0,002, sedangkan angka kumulatif muatan faktor sebesar 42,775% dan nilai reliabilitas Instrumen sebesar 0,9634. Hasil analisis data tersebut menunjukkan tingkat reliabilitas instrumen tergolong tinggi, namun validitas konstruk masih rendah. Kata kunci: pengembangan instrument, evaluasi budi pekerti.

  2. Pengembangan Program Macromedia Flash 8 untuk Pembelajaran Fisika di SMA

    Directory of Open Access Journals (Sweden)

    Wiji Susilowati

    2007-12-01

    Full Text Available Tujuan penelitian adalah membuat dan mengevaluasi media pembelajaran fisika SMA menggunakan program Macromedia Flash 8. Subjek coba pada penelitian ini berjumlah 40 orang yang terdiri dari 10 siswa untuk uji coba instrumen penelitian, 10 siswa untuk ujicoba kelompok kecdl, dan 20 siswa untuk uji coba lapangan. Pengumpulan data dilakukan dengan mengguna­kan kuesioner dan tes fisika (pre-test dan post-test. Evaluasi terhadap program ditinjau dari aspek pembelajaran dan aspek media. Kritik dan saran digunakan untuk memperbaiki program. Hasil penelitian menunjukkan bahwa program Macromedia Flash 8 untuk pembelajaran fisika di SMA: (1 dirancang sesuai dengan prinsip-prinsip desain pembelajaran, (2 terbukti mampu menaikkan skor rerata tes fisika siswa sebesar 55,42%, (3 memiliki efisiensi waktu yang tinggi, (4 ditinjau dari aspek media Hinilai cukup bagus/menarik (dinilai/dikategorikan sedang oleh siswa, (5 ditinjau dari aspek pembelajaran secara keseluruhan program ini dinilai tinggi/jelas dimengerti oleh siswa, (6 ditinjau dari aspek media dinilai menarik (bagus/kategori tinggi oleh guru fisika, dan (7 ditinjau dari aspek pembelajaran juga dinilai menarik (bagus/kategori tinggi oleh guru fisika. Kata kunci: media pembelajaran fisika diSMA.

  3. Influence of a prolonged fasting and mild activity on routine laboratory tests.

    Science.gov (United States)

    Šupak-Smolčić, Vesna; Antončić, Dragana; Ožanić, Doris; Vladilo, Ivana; Bilić-Zulle, Lidija

    2015-01-01

    Despite the standardization of the phlebotomy procedure, blood analysis is occasionally requested after recommended hours with the excuse that the patient is still fasting. We aimed to examine the influence of prolonged fasting and mild physical activity on routine laboratory tests. The study was conducted on 30 volunteers (27 female) median age 40y (20-59). Blood samples were taken in the morning (7:00-8:00a.m.) and early afternoon (1:00-2:00p.m.) after prolonged fasting and usual daily activities. Serum glucose (GLU), urea, creatinine, triglyceride, uric acid (UA), iron and electrolytes were analyzed on Roche cobas 6000 c501 and complete blood count on Siemens ADVIA 2120i. Statistical significance between the two measurements was tested using paired t-test or Wilcoxon test according to data distribution. Clinical significance was judged against calculated reference change values (RCV). A statistically significant decrease was found for red blood cell count, hemoglobin, hematocrit, mean corpuscular volume (MCV), GLU, urea, creatinine, triglycerides and electrolytes, whereas white blood cell count and iron were significantly increased. Judging against desirable bias derived from biological variation, a significant change was found for all the analytes except MCV, platelet count, UA and triglycerides. A clinically significant change was not found for any of the tested analytes when compared to RCV. Prolonged fasting and mild activity will not influence the medical decision for healthy subjects with normal results. Despite the present statistically significant change, the clinically significant change was not shown. However, the study did not include pathological results which have to be interpreted more carefully. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Detection of toxoplasma-specific immunoglobulin G in human sera: performance comparison of in house Dot-ELISA with ECLIA and ELISA.

    Science.gov (United States)

    Teimouri, Aref; Modarressi, Mohammad Hossein; Shojaee, Saeedeh; Mohebali, Mehdi; Zouei, Nima; Rezaian, Mostafa; Keshavarz, Hossein

    2018-05-08

    In the current study, performance of electrochemiluminescence immunoassay (ECLIA) in detection of anti-toxoplasma IgG in human sera was compared with that of enzyme-linked immunosorbent assay (ELISA). Furthermore, performance of an in house Dot-ELISA in detection of anti-toxoplasma IgG was compared with that of ECLIA and ELISA. In total, 219 human sera were tested to detect anti-toxoplasma IgG using Dynex DS2® and Roche Cobas® e411 Automated Analyzers. Discordant results rechecked using immunofluorescence assay (IFA). Then, sera were used in an in house Dot-ELISA to assess toxoplasma-specific IgG. Of the 219 samples, two samples were found undetermined using ECLIA but reactive using ELISA. Using IFA, the two sera were reported unreactive. Furthermore, two samples were found reactive using ECLIA and unreactive using ELISA. These samples were reported reactive using IFA. The overall agreement for the two former methods was 98% (rZ0.98.1; P house Dot-ELISA included sensitivity of 79.5, specificity of 78.2, and accuracy of 78.9%, compared to ECLIA and ELISA. Positive and negative predictive values included 82.9 and 74.2%, respectively. A 100% sensitivity was found in in house Dot-ELISA for highly reactive sera in ECLIA and ELISA. ECLIA is appropriate for the first-line serological screening tests and can replace ELISA due to high speed, sensitivity, and specificity, particularly in large laboratories. Dot-ELISA is a rapid, sensitive, specific, cost-effective, user-friendly, and field-portable technique and hence can be used for screening toxoplasmosis, especially in rural fields or less equipped laboratories.

  5. Étude de la mouillabilité des roches réservoir à l'échelle du pore par cryomicroscopie électronique à balayage Wettability of Reservoir Rock At the Pore Scale: Contribution of Cryo-Scanning Electron Microscopy

    Directory of Open Access Journals (Sweden)

    Fassi-Fihri O.

    2006-11-01

    Full Text Available Le but de cette étude est de caractériser, à l'échelle du pore, la mouillabilité des roches réservoir, en relation avec leur géométrie et/ou leur minéralogie. Cette caractérisation se fait, après congélation des échantillons, par l'observation de la distribution des fluides au sein du milieu poreux (saumure et huile brute, en microscopie électronique à balayage. Les expériences ont d'abord été effectuées sur des roches modèles parfaitement mouillables à l'eau, verre fritté et grès naturels. Certains de ces minéraux ont été rendus hydrophobes par greffage de silane. L'étude de ces systèmes a mis en évidence une corrélation entre la mouillabilité et la distribution des fluides. Puis, une roche réservoir (grès argileux de la formation de Brent, de mer du Nord connue comme étant de mouillabilité intermédiaire a été étudiée. Un travail précédent (étude de déplacements eau/huile par tomographie X avait abouti à la conclusion que si ces roches présentaient des hétérogénéités de mouillabilité, l'échelle de ces hétérogénéités devait être inférieure au millimètre. Les études de cryomicroscopie ont montré le caractère hydrophobe de la kaolinite, tandis que les illites, le quartz et les feldspaths sont préférentiellement mouillables à l'eau. L'imbibition spontanée d'huile pourrait ainsi être attribuée à l'existence au sein de la roche d'un réseau de kaolinite, tandis que l'imbibition spontanée de saumure serait due à l'existence d'un second réseau plus ou moins imbriqué avec le premier et constitué des autres minéraux. Un autre cas de roche réservoir a été étudié, à savoir un carbonate du Moyen-Orient. Les mésopores intergranulaires y ont été observés comme étant mouillables à l'huile tandis que les micropores restaient mouillables à l'eau. Dans ce cas, la mouillabilité intermédiaire de ces échantillons s'explique par la géométrie plutôt que par la min

  6. Prevalence of Sexually Transmitted Infection in Teenage Pregnancy in Rajavithi Hospital, Thailand.

    Science.gov (United States)

    Asavapiriyanont, Suvanna; Chaovarindr, Udom; Kaoien, Surasak; Chotigeat, Uraiwan; Kovavisarach, Ekachai

    2016-02-01

    Behavioral and social changes in the modern era have triggered an increase in the incidence of early sexual contact and teenage pregnancy. Since there is no routine Gonococcal & Chlamydial (GC & CT) screening in teens in antenatal clinics in Thailand, the present study was performed to find the prevalence of STI, especially Chlamydial infection, in teenage pregnancy. To evaluate the prevalence of sexually transmitted infections (STIs), especially Chlamydial infection (CT), in teenage pregnancy and its related factors. One hundred and twenty-one teenage pregnancies were recruited at the ANC in Rajavithi Hospital from October 2006 to May 2007. After signing informed consent forms, they were asked to answer questionnaires about baseline data, sexual information and risk factors, after which urine specimens were collected for screening for GC and CT using the PCR technique (AMPLICOR by Roche). Later, pelvic examination was per formed by the gynecologist at the STD (sexually transmitted disease) clinic. All the data and LAB results were recorded and analyzed by the SPSS program. Numbers, percentages, means with SD, Chi-squared test, Fisher's exact test and odds ratio were used. Potential risk factors were analyzed using binary logistic regression. The prevalence of STI in pregnant teenagers was 28.1% (CT = 19.8%, GC = 1.7%, hepatitis B = 3.3%, trichomoniasis 1.7%, Herpes simplex = 0.8% and condyloma acuminata = 0.8%). No Syphilis, chancroid or HIV were found in the present study Other non-STI like candidiasis and bacterial vaginosis were found in 45.5% of participants (candidiasis and bacterial vaginosis at 19.0% and 24.8%, respectively). The risk of CT infection was significantly related (6.9 times higher) to having previous sexual contact before the current partner (95% CI, 1.8-27.0). STI, especially Chlamydial infection, was found in a significant number of teenage pregnancies. Measures should be taken to prevent this resulting in complicated outcomes in the future.

  7. Survival of infants born to HIV-positive mothers, by feeding modality, in Rakai, Uganda.

    Directory of Open Access Journals (Sweden)

    Joseph Kagaayi

    Full Text Available BACKGROUND: Data comparing survival of formula-fed to breast-fed infants in programmatic settings are limited. We compared mortality and HIV-free of breast and formula-fed infants born to HIV-positive mothers in a program in rural, Rakai District Uganda. METHODOLOGY/PRINCIPAL FINDINGS: One hundred eighty two infants born to HIV-positive mothers were followed at one, six and twelve months postpartum. Mothers were given infant-feeding counseling and allowed to make informed choices as to whether to formula-feed or breast-feed. Eligible mothers and infants received antiretroviral therapy (ART if indicated. Mothers and their newborns received prophylaxis for prevention of mother-to-child HIV transmission (pMTCT if they were not receiving ART. Infant HIV infection was detected by PCR (Roche Amplicor 1.5 during the follow-up visits. Kaplan Meier time-to-event methods were used to compare mortality and HIV-free survival. The adjusted hazard ratio (Adjusted HR of infant HIV-free survival was estimated by Cox regression. Seventy-five infants (41% were formula-fed while 107 (59% were breast-fed. Exclusive breast-feeding was practiced by only 25% of breast-feeding women at one month postpartum. The cumulative 12-month probability of infant mortality was 18% (95% CI = 11%-29% among the formula-fed compared to 3% (95% CI = 1%-9% among the breast-fed infants (unadjusted hazard ratio (HR = 6.1(95% CI = 1.7-21.4, P-value < 0.01. There were no statistically significant differentials in HIV-free survival by feeding choice (86% in the formula-fed compared to 96% in breast-fed group (Adjusted RH = 2.8[95%CI = 0.67-11.7, P-value = 0.16] CONCLUSIONS/SIGNIFICANCE: Formula-feeding was associated with a higher risk of infant mortality than breastfeeding in this rural population. Our findings suggest that formula-feeding should be discouraged in similar African settings.

  8. Pengembangan Modul Fisika Pokok Bahasan Hukum Newton bagi Anak Berkebutuhan Khusus (Tunanetra Di Kelas Inklusi SMA/MA Kelas X

    Directory of Open Access Journals (Sweden)

    Fitriany Yudistia R

    2014-04-01

    Full Text Available Siswa tunanetra SMA Muhammadiyah 4 Yogyakarta, MAN Maguwoharjo dan SMAN 1 Sewon belum memiliki sumber belajar mandiri berupa modul Braille khususnya pada materi Hukum Newton. Berdasarkan kenyataan ini maka dibutuhkan sebuah sumber belajar yang didesain khusus bagi siswa tunanetra di kelas Inklusi yakni modul Braille pada pokok bahasan Hukum Newton.Telah dilakukan penelitian yang bertujuan untuk: (1 mengembangkan modul fisika pokok bahasan Hukum Newton untuk siswa tunanetra SMA/MA kelas X sebagai sumber belajar mandiri, (2 mengetahui kualitas modul fisika Braille materi Hukum Newton untuk siswa tunanetra SMA/MA kelas X, (3 mengetahui respon siswa terhadap modul fisika Braille yang telah dikembangkan.Penelitian ini merupakan penelitian R & D dengan model prosedural yang mengadaptasi dari pengembangan perangkat model 4-D, yakni Define, Design, Develop, and Disseminate. Instrumen penelitian berupa angket kualitas modul yaitu menggunakan skala Likert yang dibuat dalam bentuk checklist. Instrumen untuk siswa berupa angket respon siswa yaitu menggunakan skala Guttman yang dibuat dalam bentuk checklist. Modul dinilai kualitasnya oleh 3 ahli materi, 1 ahli media, dan 2 guru fisika SMA/MA. Kelayakan modul berdasarkan respon siswa pada uji coba terbatas sebanyak 2 siswa dan uji coba luas sebanyak 8 siswa.Hasil penelitian berdasarkan penilaian dari ahli materi, ahli media dan guru fisika SMA/MA modul memiliki kategori sangat baik (SB. Persentase keidealan menurut ahli materi adalah 87,88%; persentase keidealan menurut ahli media adalah 90,00% dan persentase keidealan menurut guru Fisika SMA/MA adalah 75,00%. Respon siswa terhadap modul fisika Braille pada uji coba terbatas diperoleh persentase 97,22%; sedangkan pada uji coba luas diperoleh persentase 89,58%. Hasil penelitian ini menunjukkan bahwa modul layak dijadikan sebagai salah satu sumber belajar mandiri bagi siswa tunanetra.

  9. PENGEMBANGAN INSTRUMEN ASESMEN BERPIKIR KRITIS UNTUK SISWA SMP KELAS VII PADA MATERI INTERAKSI MAKHLUK HIDUP DENGAN LINGKUNGAN

    Directory of Open Access Journals (Sweden)

    Dharmawati Dharmawati

    2016-08-01

    Full Text Available This study aims to generate critical thinking assessment instrument for seven graders within organism interaction in an environment with an appropriate validity and reliability level. The design of this instrument is developed using stages suggested by Borg and Gall. The stages are researching and collecting information, planning, developing a preliminary product, conducting the limited examination, revising product from limited examination, field testing, revising product from field testing, and finalizing product. The result of content and construction validation shows that the level of feasibility is 88,35% and categorized as very feasible. While the degree of readability of assessment items is 93,51% and it is categorized as excellent. The coefficient of inter-rater reliability of assessment items is 0,951 and categorized as excellent. The instrument acquires reliability coefficient 0,792 for multiple choice and 0,753 for essay items. This study shows that the content, construction, and items in assessment are feasible. Penelitian ini bertujuan untuk menghasilkan instrumen asesmen berpikir kritis untuk siswa SMP kelas VII pada materi interaksi makhluk hidup dengan lingkungan dengan tingkat validitas dan reliabilitas yang memadai. Rancangan penelitian menggunakan model pengembangan menurut Borg & Gall, yang meliputi langkah-langkah: penelitian dan pengumpulan informasi, perencanaan, pengembangan produk awal, uji coba terbatas, revisi produk uji coba terbatas, uji coba lapangan, revisi uji coba produk lapangan, dan penyempurnaan produk akhir. Berdasarkan hasil validasi isi dan konstruk diperoleh tingkat kelayakan produk sebesar 88,35% berada pada kriteria sangat layak. Tingkat keterbacaan soal asesmen sebesar 93,51% dengan kategori sangat baik. Koefisien inter-rater reliability pada soal asesmen bentuk penugasan sebesar 0,951 dengan kategori sangat baik. Instrumen tersebut mempunyai koefisien reliabilitas sebesar 0,792 (soal pilihan ganda dan

  10. Intramolecular Oxidative O-Demethylation of an Oxoferryl Porphyrin Complexed with a Per-O-methylated β-Cyclodextrin Dimer.

    Science.gov (United States)

    Kitagishi, Hiroaki; Kurosawa, Shun; Kano, Koji

    2016-11-22

    The intramolecular oxidation of ROCH 3 to ROCH 2 OH, where the latter compound spontaneously decomposed to ROH and HCHO, was observed during the reaction of the supramolecular complex (met-hemoCD3) with cumene hydroperoxide in aqueous solution. Met-hemoCD3 is composed of meso-tetrakis(4-sulfonatophenyl)porphinatoiron(III) (Fe III TPPS) and a per-O-methylated β-cyclodextrin dimer having an -OCH 2 PyCH 2 O- linker (Py=pyridine-3,5-diyl). The O=Fe IV TPPS complex was formed by the reaction of met-hemoCD3 with cumene hydroperoxide, and isolated by gel-filtration chromatography. Although the isolated O=Fe IV TPPS complex in the cyclodextrin cage was stable in aqueous solution at 25 °C, it was gradually converted to Fe II TPPS (t 1/2 =7.6 h). This conversion was accompanied by oxidative O-demethylation of an OCH 3 group in the cyclodextrin dimer. The results indicated that hydrogen abstraction by O=Fe IV TPPS from ROCH 3 yields HO-Fe III TPPS and ROCH 2 . . This was followed by radical coupling to afford Fe II TPPS and ROCH 2 OH. The hemiacetal (ROCH 2 OH) immediately decomposed to ROH and HCHO. This study revealed the ability of oxoferryl porphyrin to induce two-electron oxidation. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Comparación de los métodos de cuantificación de carga viral de VIH: COBAS® AmpliPrep/COBAS® TaqMan HIV-1 test, v 2.0, y VERSANT HIV-1 RNA 1.0 Assay (kPCR Comparison of COBAS® AmpliPrep/COBAS® TaqMan HIV-1 test, v 2.0 and VERSANT HIV-1 RNA 1.0 (kPCR assays for HIV-1 plasma viral load

    Directory of Open Access Journals (Sweden)

    María Isabel Múnera-Jaramillo

    2012-03-01

    Full Text Available Objetivo. El propósito del estudio fue evaluar el desempeño del método VERSANTHIV-1RNA 1.0 Assay® (kPCR (Siemens, para la cuantificación de la carga viral en pacientes con VIH-1, en comparación con el método COBAS® AmpliPrep/COBAS TaqMan HIV-1 test®, v2.0 (Roche Diagnostics (CAP/CTM. Métodos. Las muestras fueron tomadas en dos tubos con EDTA, de 60 pacientes remitidos por el médico tratante para pruebas de carga viral como parte de su control de rutina de VIH/sida, y fueron procesadas para la cuantificación del ARN del VIH-1 por ambas técnicas. Se hizo análisis de regresión y se calcularon los coeficientes de correlación de Pearson, y los de correlación y concordancia de Lin. Se evalúo la concordancia entre las dos técnicas mediante el método de Bland-Altman. Resultados. El promedio de la carga viral por el método CAP/CTM fue 3,2±1,4 long10 copias/ml y, por el método kPCR, 3,0±1,3 long10 copias/ml. El 86,7 % de muestras presentó diferencias entre los dos métodos, menores de 0,5 long10 copias/ml, y el 13,3 % presentó diferencias mayores. El coeficiente de correlación de Pearson entre los dos métodos fue de 0,97 (IC95% 0,95-0,99 y el índice kappa ponderado entre los dos métodos en diferentes rangos de concentración, fue de 0,91 (IC95% 0,87-0,96. El promedio de las diferencias entre las mediciones fue 0,22 long10 copias/ml (IC95% -0,45 a 0,89. Conclusión. Las dos técnicas evaluadas fueron comparables, con el método kPCR se observaron resultados más bajos.Objective: The purpose of this study was to evaluate the performance of the kPCR VERSANT (™ 440 HIV-1RNA 3.0 Assay® (Siemens method for the quantification of viral load in HIV-1 patients, compared to the COBAS AmpliPrep/COBASTaqMan HIV-1 test®, v. 2.0 (Roche Diagnostics (CAP/CTM. Methods: Samples were taken in 2 tubes with EDTA, in 60 patients referred by the attending physician for viral load tests as part of their routine control of HIV/AIDS, and were

  12. Droplet digital PCR-based EGFR mutation detection with an internal quality control index to determine the quality of DNA.

    Science.gov (United States)

    Kim, Sung-Su; Choi, Hyun-Jeung; Kim, Jin Ju; Kim, M Sun; Lee, In-Seon; Byun, Bohyun; Jia, Lina; Oh, Myung Ryurl; Moon, Youngho; Park, Sarah; Choi, Joon-Seok; Chae, Seoung Wan; Nam, Byung-Ho; Kim, Jin-Soo; Kim, Jihun; Min, Byung Soh; Lee, Jae Seok; Won, Jae-Kyung; Cho, Soo Youn; Choi, Yoon-La; Shin, Young Kee

    2018-01-11

    In clinical translational research and molecular in vitro diagnostics, a major challenge in the detection of genetic mutations is overcoming artefactual results caused by the low-quality of formalin-fixed paraffin-embedded tissue (FFPET)-derived DNA (FFPET-DNA). Here, we propose the use of an 'internal quality control (iQC) index' as a criterion for judging the minimum quality of DNA for PCR-based analyses. In a pre-clinical study comparing the results from droplet digital PCR-based EGFR mutation test (ddEGFR test) and qPCR-based EGFR mutation test (cobas EGFR test), iQC index ≥ 0.5 (iQC copies ≥ 500, using 3.3 ng of FFPET-DNA [1,000 genome equivalents]) was established, indicating that more than half of the input DNA was amplifiable. Using this criterion, we conducted a retrospective comparative clinical study of the ddEGFR and cobas EGFR tests for the detection of EGFR mutations in non-small cell lung cancer (NSCLC) FFPET-DNA samples. Compared with the cobas EGFR test, the ddEGFR test exhibited superior analytical performance and equivalent or higher clinical performance. Furthermore, iQC index is a reliable indicator of the quality of FFPET-DNA and could be used to prevent incorrect diagnoses arising from low-quality samples.

  13. Factors Affecting the Nutritional Status of Pregnant Women

    Science.gov (United States)

    1989-01-01

    1988). Circumferences. In T. G. Lohman, A. F. Roche & R. Mortorell [Eds.], 8uth cumLn_ u jQn Reference Manual [pp.39-5q]. Illinois: Human Kinetics Books...Roche, A. F. & Seefeldt, U. D. 188). Circumferences. In T. G. Lohman, A. F. Roche & R. Mortorell [Eds.], eDbhPoics _odad io Reference Manual [pp.39-5q3...respiration and circulation immediately after birth as shown by low Apgar scores, hypoglycemia, hWpothermia and infection. They are more prone to suffer

  14. Collisional Fragmentation Is Not a Barrier to Close-in Planet Formation

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, Joshua; Tremaine, Scott [Department of Astrophysical Sciences, Princeton University, Princeton, NJ 08544 (United States); Chambers, John, E-mail: joshuajw@princeton.edu [Department of Terrestrial Magnetism, Carnegie Institution for Science, Washington, DC 20015 (United States)

    2017-11-01

    Collisional fragmentation is shown to not be a barrier to rocky planet formation at small distances from the host star. Simple analytic arguments demonstrate that rocky planet formation via collisions of homogeneous gravity-dominated bodies is possible down to distances of order the Roche radius ( r {sub Roche}). Extensive N -body simulations with initial bodies ≳1700 km that include plausible models for fragmentation and merging of gravity-dominated bodies confirm this conclusion and demonstrate that rocky planet formation is possible down to ∼1.1 r {sub Roche}. At smaller distances, tidal effects cause collisions to be too fragmenting to allow mass buildup to a final, dynamically stable planetary system. We argue that even differentiated bodies can accumulate to form planets at distances that are not much larger than r {sub Roche}.

  15. Ravimid, risk, raha & tervis / Inge Pitsner

    Index Scriptorium Estoniae

    Pitsner, Inge

    2008-01-01

    Ravimifirma Roche Eesti OÜ tegevjuht Kadri Mägi selgitab ravimiäri toimemehhanisme ning põhjuseid, miks ravimitööstus on riskantne ja kallis valdkond. Lisa: Mis on farmakoökonoomika?; Roche Eesti kontor

  16. Hazardous Waste Cleanup: DSM Nutritional Products Incorporated in Belvidere, New Jersey

    Science.gov (United States)

    DSM Nutritional Products, Inc., formerly Hoffman-LaRoche (Roche) Belvidere is located on Maunkachunk Road in White Township, New Jersey. The site occupies approximately 500 acres in Warren County. The facility has been manufacturing vitamins since 1961.

  17. Short-term Variability of Vitamin D-Related Biomarkers.

    Science.gov (United States)

    Lutsey, Pamela L; Parrinello, Christina M; Misialek, Jeffrey R; Hoofnagle, Andy N; Henderson, Clark M; Laha, Thomas J; Michos, Erin D; Eckfeldt, John H; Selvin, Elizabeth

    2016-12-01

    Quantifying the variability of biomarkers is important, as high within-person variability can lead to misclassification of individuals. Short-term variability of important markers of vitamin D metabolism is relatively unknown. A repeatability study was conducted in 160 Atherosclerosis Risk in Communities study participants (60% female, 28% black, mean age 76 years). Fasting serum was drawn at 2 time points, a median of 6 (range 3-13) weeks apart. Vitamin D binding protein (VDBP) and 25-hydroxyvitamin D [25(OH)D] were measured by LC-MS, fibroblast growth factor (FGF23) and parathyroid hormone (PTH) by enzyme-linked immunoassay, and calcium and phosphorus by Roche Cobas 6000. Free and bioavailable 25(OH)D were calculated. We calculated the within-person CV (CV W ), intraclass correlation coefficient (ICC), Spearman rank correlation coefficient (r), and percent reclassified. The CV W was lowest for calcium (2.0%), albumin (3.6%), 25(OH)D (6.9%), VDBP (7.0%) and phosphorus (7.6%); intermediate for free 25(OH)D (9.0%) and bioavailable 25(OH)D (9.9%); and highest for PTH (16.7%) and FGF23 (17.8%). Reclassification was highest for PTH, VDBP, and phosphorus (all 7.5%). The ICC and r were highest (≥0.80) for 25(OH)D, free 25(OH)D, bioavailable 25(OH)D and PTH, but somewhat lower (approximately 0.60-0.75) for the other biomarkers. Six-week short-term variability, as assessed by CV W , was quite low for VDBP, calcium and phosphorus, but fairly high for FGF23 and PTH. As such, multiple measurements of FGF23 and PTH may be needed to minimize misclassification. These results provide insight into the extent of potential misclassification of vitamin D markers in research and clinical settings. © 2016 American Association for Clinical Chemistry.

  18. False-positive pregnancy test after transfusion of solvent/detergent-treated plasma.

    Science.gov (United States)

    Jilma-Stohlawetz, Petra; Wreford-Bush, Tim; Mills, Francesca; Davidson, Fiona; Kursten, Friedrich W; Jilma, Bernd; Birchall, Janet

    2017-12-01

    The transmission of pathogens, antibodies, and proteins is a possible consequence of blood product transfusion. A female patient had an unexpected positive serum β-human chorionic gonadotropin result, indicative of pregnancy, after she had received a transfusion with 1 unit of platelet concentrate, 4 units of red blood cells, and 4 units of pooled solvent/detergent-treated plasma (Octaplas). To investigate the possibility of passive transfusion of β-human chorionic gonadotropin from the plasma transfusion, one additional unit from the same batch was thawed and analyzed. To validate the β-human chorionic gonadotropin assay for use in solvent/detergent-treated plasma and to investigate any interference in the assay, dilution experiments were performed using the implicated plasma batch diluted with male and non-pregnant female sera. Also, plasma from a known pregnant woman was diluted with Octaplas (tested negative for β-human chorionic gonadotropin) and with a male serum to validate the assay for use in solvent/detergent-treated plasma. The implicated solvent/detergent-treated plasma had a mean β-human chorionic gonadotropin level of 91.5 mIU/mL. Results from the dilution experiments revealed an excellent correlation (r > 0.99) between β-human chorionic gonadotropin measurement in solvent/detergent-treated plasma and male serum and no over or under recovery of the expected results. Further measurements of β-human chorionic gonadotropin levels in the female recipient revealed an estimated half-life of 6 hours. This case demonstrates the importance of considering the possibility of passive transmission of analytes to a patient from the transfusion of blood products. Furthermore, the measurement of β-human chorionic gonadotropin is valid in solvent/detergent-treated plasma using a Roche Cobas analyzer. © 2017 AABB.

  19. An OPTIMIZE study retrospective analysis for management of telaprevir-treated hepatitis C virus (HCV)-infected patients by use of the Abbott RealTime HCV RNA assay.

    Science.gov (United States)

    Sarrazin, Christoph; Dierynck, Inge; Cloherty, Gavin; Ghys, Anne; Janssen, Katrien; Luo, Donghan; Witek, James; Buti, Maria; Picchio, Gaston; De Meyer, Sandra

    2015-04-01

    Protease inhibitor (PI)-based response-guided triple therapies for hepatitis C virus (HCV) infection are still widely used. Noncirrhotic treatment-naive and prior relapser patients receiving telaprevir-based treatment are eligible for shorter, 24-week total therapy if HCV RNA is undetectable at both weeks 4 and 12. In this study, the concordance in HCV RNA assessments between the Roche High Pure System/Cobas TaqMan and Abbott RealTime HCV RNA assays and the impacts of different HCV RNA cutoffs on treatment outcome were evaluated. A total of 2,629 samples from 663 HCV genotype 1 patients receiving telaprevir/pegylated interferon/ribavirin in OPTIMIZE were analyzed using the High Pure System and reanalyzed using Abbott RealTime (limits of detection, 15.1 IU/ml versus 8.3 IU/ml; limits of quantification, 25 IU/ml versus 12 IU/ml, respectively). Overall, good concordance was observed between the assays. Using undetectable HCV RNA at week 4, 34% of the patients would be eligible for shorter treatment duration with Abbott RealTime versus 72% with the High Pure System. However, using Abbott RealTime, a similar proportion (74%) would be eligible. Of the patients receiving 24-week total therapy, 87% achieved a sustained virologic response with undetectable HCV RNA by the High Pure System or Abbott RealTime; however, 92% of the patients with undetectable HCV RNA by Abbott RealTime achieved a sustained virologic response. Using undetectable HCV RNA as the cutoff, the more sensitive Abbott RealTime assay would identify fewer patients eligible for shorter treatment than the High Pure System. Our data confirm the Abbott RealTime assay, to determine eligibility for shortened PI-based HCV treatment. (The study was registered with ClinicalTrials.gov under registration no. NCT01241760.). Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  20. Verification of an immunoturbidimetric assay for heart-type fatty acid-binding protein (H-FABP) on a clinical chemistry platform and establishment of the upper reference limit.

    Science.gov (United States)

    Da Molin, Simona; Cappellini, Fabrizio; Falbo, Rosanna; Signorini, Stefano; Brambilla, Paolo

    2014-11-01

    Heart-type fatty acid-binding protein (H-FABP) is an early biomarker of cardiac injury. Randox Laboratories developed an immunoturbidimetric H-FABP assay for non-proprietary automated clinical chemistry analysers that could be useful in the emergency department. We verified the analytical performances claimed by Randox Laboratories on Roche Cobas 6000 clinical chemistry platform in use in our laboratory, and we defined our own 99th percentile upper reference limit for H-FABP. For the verification of method performances, we used pools of spared patient samples from routine and two levels of quality control material, while samples for the reference value study were collected from 545 blood donors. Following CLSI guidelines we verified limit of blank (LOB), limit of detection (LOD), limit of quantitation (LOQ), repeatability and within-laboratory precision, trueness, linearity, and the stability of H-FABP in EDTA over 24h. The LOQ (3.19 μg/L) was verified with a CV% of 10.4. The precision was verified for the low (mean 5.88 μg/L, CV=6.7%), the medium (mean 45.28 μg/L, CV=3.0%), and the high concentration (mean 88.81 μg/L, CV=4.0%). The trueness was verified as well as the linearity over the indicated measurement interval of 0.747-120 μg/L. The H-FABP in EDTA samples is stable throughout 24h both at room temperature and at 4 °C. The H-FABP 99th percentile upper reference limit for all subjects (3.60 μg/L, 95% CI 3.51-3.77) is more appropriate than gender-specific ones that are not statistically different. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  1. Bacterial vaginosis, aerobic vaginitis, vaginal inflammation and major Pap smear abnormalities.

    Science.gov (United States)

    Vieira-Baptista, P; Lima-Silva, J; Pinto, C; Saldanha, C; Beires, J; Martinez-de-Oliveira, J; Donders, G

    2016-04-01

    The purpose of this investigation was to evaluate the impact of the vaginal milieu on the presence of abnormal Pap smears and a positive human papilloma virus (HPV) test. A cross-sectional study was conducted between June 2014 and May 2015, evaluating the vaginal discharge by fresh wet mount microscopy and comparing these data with Pap smear findings. Wet mount slides were scored for bacterial vaginosis (BV), aerobic vaginitis (AV), presence of Candida and Trichomonas vaginalis. Cytologic evaluation was done on all Pap smears according to the Bethesda criteria. The cobas© HPV Test (Roche) was performed for HPV detection. A total of 622 cases were evaluated. The mean age of the patients was 41.6 ± 10.65 years (range 21-75). Eighty-three women (13.3 %) had a cytology result worse than low-grade squamous intraepithelial lesion (LSIL). When comparing this group with the one with normal or minor [atypical squamous cells of undetermined significance (ASC-US) or LSIL] Pap smear abnormalities, there were no differences in the presence of Candida (32.5 % vs. 33.2 %, p = 1.0), absence of lactobacilli (38.6 % vs. 32.5 %, p = 0.32) or BV (20.5 % vs. 13.2 %, p = 0.09). On the other hand, moderate or severe inflammation (msI) (41.0 % vs. 28.8 %, p = 0,04), moderate or severe AV (msAV) (16.9 % vs. 7.2 %, p = 0.009) and msAV/BV (37.3 % vs. 20.0 %, p = 0.001) were more common in women with such major cervical abnormalities. No significant association was found between deviations of the vaginal milieu and high-risk HPV infection. The presence of msI or msAV, but not BV, is independently associated with an increased risk of major cervical cytological abnormalities, but not with HPV infection.

  2. Clinical, laboratory and instrumental methods of pre-surgical diagnosis of the parathyroid glands cancer

    Directory of Open Access Journals (Sweden)

    Natalia G. Mokrysheva

    2017-12-01

    Full Text Available Backgraund. When defining symptomatic primary hyperparathyroidism (PHPT, differential diagnosis between a benign and malignant neoplasm of parathyroid glands (PG may be challenging. The diagnosis of carcinoma or a benign tumor determines the extent of the surgical intervention and further observation tactics. Aims. The purpose of the study is to determine the clinical and laboratory and instrumental predictors of PG cancer. Materials and methods. A retrospective study included 385 patients with PHPT (273 with adenomas of the PG, 66 with hyperplasia, and 19 patients with cancer of the PG, who had been examined and operated from 2000 to 2014. The primary goal of the study was to define the level of ionized calcium (Ca++, parathyroid hormone (PTH, and the volume of the tumor PG specific for cancer of the PG. The level of parathyroid hormone (PTH was determined by electrochemoluminescent method on the Roche analyzer Cobas 6000; ionized calcium (Ca++ ion-selective method. The size of the PG was determined by the ellipse formula: V(cm3 = (A × B × C × 0.49 by ultrasound investigation using the Valuson E8 device from General Electric. Results. The group of patients with PG carcinoma showed the increased level of Ca++ of more than 1.60 mmol/l (p = 0.004 and increased level of PTH of more than 600 pg/ml (p = 0.03. The size of tumors of more than 6 cm3 is more typical to malignant neoplasm compared to the adenoma of the PG (p = 0.01. Conclusions. The group of patients with PHPT that are at risk of having PG carcinoma include individuals that have a combination of the following indicators: PTH levels of more than 600 pg/ml, an increase in ionized calcium of more than 1.60 mmol/l, the tumor size of more than 6 cm3.

  3. Evaluation of a high resolution genotyping method for Chlamydia trachomatis using routine clinical samples.

    Directory of Open Access Journals (Sweden)

    Yibing Wang

    2011-02-01

    Full Text Available Genital chlamydia infection is the most commonly diagnosed sexually transmitted infection in the UK. C. trachomatis genital infections are usually caused by strains which fall into two pathovars: lymphogranuloma venereum (LGV and the genitourinary genotypes D-K. Although these genotypes can be discriminated by outer membrane protein gene (ompA sequencing or multi-locus sequence typing (MLST, neither protocol affords the high-resolution genotyping required for local epidemiology and accurate contact-tracing.We evaluated variable number tandem repeat (VNTR and ompA sequencing (now called multi-locus VNTR analysis and ompA or "MLVA-ompA" to study local epidemiology in Southampton over a period of six months. One hundred and fifty seven endocervical swabs that tested positive for C. trachomatis from both the Southampton genitourinary medicine (GUM clinic and local GP surgeries were tested by COBAS Taqman 48 (Roche PCR for the presence of C. trachomatis. Samples tested as positive by the commercial NAATs test were genotyped, where possible, by a MLVA-ompA sequencing technique. Attempts were made to isolate C. trachomatis from all 157 samples in cell culture, and 68 (43% were successfully recovered by repeatable passage in culture. Of the 157 samples, 93 (i.e. 59% were fully genotyped by MLVA-ompA. Only one mixed infection (E & D in a single sample was confirmed. There were two distinct D genotypes for the ompA gene. Most frequent ompA genotypes were D, E and F, comprising 20%, 41% and 16% of the type-able samples respectively. Within all genotypes we detected numerous MLVA sub-types.Amongst the common genotypes, there are a significant number of defined MLVA sub-types, which may reflect particular background demographics including age group, geography, high-risk sexual behavior, and sexual networks.

  4. Evaluation of 12 blood glucose monitoring systems for self-testing: system accuracy and measurement reproducibility.

    Science.gov (United States)

    Freckmann, Guido; Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Link, Manuela; Haug, Cornelia

    2014-02-01

    Systems for self-monitoring of blood glucose (SMBG) have to provide accurate and reproducible blood glucose (BG) values in order to ensure adequate therapeutic decisions by people with diabetes. Twelve SMBG systems were compared in a standardized manner under controlled laboratory conditions: nine systems were available on the German market and were purchased from a local pharmacy, and three systems were obtained from the manufacturer (two systems were available on the U.S. market, and one system was not yet introduced to the German market). System accuracy was evaluated following DIN EN ISO (International Organization for Standardization) 15197:2003. In addition, measurement reproducibility was assessed following a modified TNO (Netherlands Organization for Applied Scientific Research) procedure. Comparison measurements were performed with either the glucose oxidase method (YSI 2300 STAT Plus™ glucose analyzer; YSI Life Sciences, Yellow Springs, OH) or the hexokinase method (cobas(®) c111; Roche Diagnostics GmbH, Mannheim, Germany) according to the manufacturer's measurement procedure. The 12 evaluated systems showed between 71.5% and 100% of the measurement results within the required system accuracy limits. Ten systems fulfilled with the evaluated test strip lot minimum accuracy requirements specified by DIN EN ISO 15197:2003. In addition, accuracy limits of the recently published revision ISO 15197:2013 were applied and showed between 54.5% and 100% of the systems' measurement results within the required accuracy limits. Regarding measurement reproducibility, each of the 12 tested systems met the applied performance criteria. In summary, 83% of the systems fulfilled with the evaluated test strip lot minimum system accuracy requirements of DIN EN ISO 15197:2003. Each of the tested systems showed acceptable measurement reproducibility. In order to ensure sufficient measurement quality of each distributed test strip lot, regular evaluations are required.

  5. Hepatoprotection and neuroprotection induced by low doses of IGF-II in aging rats

    Directory of Open Access Journals (Sweden)

    Barhoum Rima

    2011-07-01

    Full Text Available Abstract Background GH and IGFs serum levels decline with age. Age-related changes appear to be associated to decreases in these anabolic hormones. We have previously demonstrated that IGF-I replacement therapy improves insulin resistance, lipid metabolism and reduces oxidative damage (in brain and liver in aging rats. Using the same experimental model, the aim of this work was to study whether the exogenous administration of IGF-II, at low doses, acts analogous to IGF-I in aging rats. Methods Three experimental groups were included in this study: young healthy controls (yCO, 17 weeks old; untreated old rats (O, 103 weeks old; and aging rats treated with IGF-II (O+IGF-II, 2 μg * 100 g body weight-1 * day-1 for 30 days. Analytical parameters were determined in serum by routine laboratory methods using an autoanalyzer (Cobas Mira; Roche Diagnostic System, Basel, Switzerland. Serum levels of hormones (testosterone, IGF-I and insulin were assessed by RIA. Serum Total Antioxidant Status was evaluated using a colorimetric assay. Mitochondrial membrane potential was evaluated using rhodamine 123 dye (adding different substrates to determine the different states. ATP synthesis in isolated mitochondria was determined by an enzymatic method. Results Compared with young controls, untreated old rats showed a reduction of IGF-I and testosterone levels with a decrease of serum total antioxidant status (TAS. IGF-II therapy improved serum antioxidant capability without modifying testosterone and IGF-I circulating concentrations. In addition, IGF-II treatment reduced oxidative damage in brain and liver, improving antioxidant enzyme activities and mitochondrial function. IGF-II was also able to reduce cholesterol and triglycerides levels increasing free fatty acids concentrations. Conclusions We demonstrate that low doses of IGF-II induce hepatoprotective, neuroprotective and metabolic effects, improving mitochondrial function, without affecting testosterone and

  6. Immunohistochemical detection of the BRAF V600E mutation in papillary thyroid carcinoma. Evaluation against real-time polymerase chain reaction.

    Science.gov (United States)

    Paja Fano, Miguel; Ugalde Olano, Aitziber; Fuertes Thomas, Elena; Oleaga Alday, Amelia

    2017-02-01

    The BRAF V600E mutation is the most common genetic change in papillary thyroid carcinoma and is associated with a poorer clinical course. Usual methods for its study (DNA sequencing or molecular test based on PCR) are expensive and time-consuming. Recently, immunohistochemistry (IHC) for BRAF mutation has been introduced. To compare the results of IHC and real time PCR (RT-PCR) in the detection of BRAF V600E mutation in papillary thyroid carcinoma. Analysis of clinical and pathological differences depending on RT-PCR results is included. A prospective study was performed in 82 consecutive samples, 54 of them taken through a core needle biopsy. IHC was performed on tissue fixed for 24hours with 10% neutral formalin using the anti-BRAF V600E (VE-1) mouse monoclonal primary antibody and was rated as positive or negative. DNA was extracted from formalin-fixed, paraffin-embedded tissues by manual microdissection, and BRAF mutation was detected by RT-PCR using the Cobas® 4800 BRAF V600 mutation test (Roche). Both techniques were concordant in 81 cases, and BRAF was positive in 49. Discordance appeared in a follicular variant showing positive IHC and negative RT-PCR, attributed to histological heterogeneity. Cost of materials for IHC was less than half of the cost for RT-PCR. IHC appears to be a reliable, economical and easily available alternative to molecular biology techniques for routine detection of the BRAF V600E mutation in papillary thyroid carcinoma patients, provided optimal fixation conditions are used. It may be a useful technique in hospitals with no access to molecular biology techniques. Copyright © 2017 SEEN. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. [Detection of Staphylococcus aureus resistant to methicillin (MRSA) by molecular biology (Cepheid GeneXpert IL, GeneOhm BD, Roche LightCycler, Hyplex Evigene I2A) versus screening by culture: Economic and practical strategy for the laboratory].

    Science.gov (United States)

    Laudat, P; Demondion, E; Jouannet, C; Charron, J; Chillou, C; Salaun, V; Mankikian, B

    2012-06-01

    Patients admitted in cardiac surgery and cardiac ICU at the Clinic Saint-Gatien (Tours) are screened for MRSA at the entrance by nasal swab and culture on blood agar and selective chromogenic medium made by addition of cefoxitin: BBL CHROMagar MRSA-II BD (result obtained at Day +1). We wanted to assess the molecular biology techniques available to obtain a result at day 0 for the majority of patients and to define an economic and practical strategy for the laboratory. We studied four molecular biology techniques: Cepheid GeneXpert (Cepheid) GeneOhm (BD), LightCycler (Roche) and Hyplex (I2A). Upon reception, nasal swabs were treated by culture, considered as reference, and one of the techniques of molecular biology, according to the manufacturer's notice. We conducted four studies between April 2008 and February 2009 to obtain a significant sample for each of them. By screening we mean a method that allows us to exclude MRSA carriage for patients waiting for surgery, and not to change patient management: for example, lack of isolation measures specific to entrance, no modification of antibiotic prophylaxis during surgery and no isolation measures in the immediate postoperative period. The criteria we considered for this evaluation were: (1) technician time: time to perform one or a series of sample(s) n=10 or more (about 2h for all techniques except GeneXpert 75min), level of skilled competences (no specific training for GeneXpert); (2) results: turnaround time (all molecular biology techniques), ease of reading and results interpretations (no specialized training required for GeneXpert), failure or not (12% of failure of internal controls for GeneOhm); (3) economic: cost for one or a series of sample(s) (n=10 or more), if we considered X as the reference culture cost (10 X Hyplex and LightCycler, 20 X and 40 X for GeneXpert GeneOhm); (4) NPV: 100% for GeneXpert and LightCycler. At same sensitivity, no technique, including culture, can solve alone our problem, which

  8. Application of paper chromatography to the determination of some elements in minerals and rocks; Application de la chromatographie sur papier a la determination de certains elements dans les mineraux et les roches

    Energy Technology Data Exchange (ETDEWEB)

    Agrinier, H [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-11-01

    This publication describes our work in applying paper chromatography to the fields of mineralogy and geology. We have studied the separation and determination of the following elements: Nb, Ta, Ti, Co, Cu, Mn, Sn, Ge, As, Sb, Bi, U, Th, Be, Au, Pb, Zn, V and Mo. The development of separation methods for these various elements has led us to solve many interference problems. These methods make it possible to separate and measure mineral components. They also enable us to search for trace elements in ores, rocks soils and carbonaceous materials. Finally let us point out that this technique may equally be used for analysis in very radioactive environment. (author) [French] Dans cette etude, nous etendons le champ d'application de la chromatographie sur papier aux domaines de la mineralogie et de la geologie. Nous avons etudie la separation et la determination des elements suivants: Nb, Ta, Ti, Co, Cu, Mn, Sn, Ge, As, Sb, Bi, U, Th, Be, Au, Pb, Zn, V et Mo. La mise au point des methodes de separation concernant ces differents elements nous a amenes a resoudre de nombreux problemes d'interference. Ces methodes permettent la separation et le dosage des constituants des mineraux, ainsi que la recherche d'elements en traces dans les minerais, les roches, les sols et les materiaux carbonnes. Signalons pour terminer que cette technique peut egalement trouver son utilisation dans le domaine de l'analyse en milieu tres radio-actif. (auteur)

  9. PENGEMBANGAN MEDIA PAPAN PERMAINAN PANJAT PINANG

    Directory of Open Access Journals (Sweden)

    Desty Triastuti

    2017-10-01

    Full Text Available Media is a very important component in the learning process. Media can be used as a toll for learning, that can be easy for the teachers to learn of the material, and at the same time can be facilitate the students to accepting and understanding of the material.  The purpose of this study is to produce the product that are specialized media to help the process of thematic learning. This media serves as a tool for stimulate memory recall and reinforce the material in students of fifth grade in elementary school. The media called board games panjat pinang has been validated on the the content and design, next then tried out on one to one evaluation, 6 students on small group evaluation and 23 students on field trial. The results of the tryouts indicating the level of feasibility of teaching materials is very high. The average validity is 90,025, attractiveness 91,80, effectiveness of 92,75, and practicality 92,18, so that media announced eligible and effective for use in thematic learning especially for matter circulatory systems human and animal. Media memiliki peranan yang sangat penting dalam proses pembelajaran. Media dapat dijadikan sebagai alat bantu belajar yang dapat memudahkan guru dalam penyampain materi sekaligus memudahkan siswa dalam menerima dan memahami materi.  Tujuan penelitian ini adalah menghasilkan produk media papan permainan panjat pinang untuk pembelajaran tematik. Media ini berfungsi sebagai alat bantu menstimulasi daya ingat dan penguatan materi bagi siswa kelas V SD. Media divalidasi pada aspek isi dan desain, diujicobakan kepada satu orang siswa pada uji coba perorangan, enam siswa pada uji coba kelompok kecil dan 23 siswa pada uji coba lapangan. Hasil uji coba menunjukkan tingkat kevalidan sangat tinggi. Rata-rata kevalidan 87,7, kepraktisan 90,55, kemenarikan 92,22, dan keefektifan 91,0. Berdasarkan skor perolehan tersebur, media dinyatakan layak dan efektif untuk digunakan di dalam pembelajaran tematik,

  10. Pengembangan E-Modul Berbasis Adobe Flash CS6 pada Mata Pelajaran Penataan Barang Dagang

    Directory of Open Access Journals (Sweden)

    Indah Zahrotul Fauziah

    2016-09-01

    Full Text Available Abstract: The increasing of technology development gives several new things. They are both the technology development in the general aspect and in education aspect. Those developments demand the educators to develop the innovative learning. One of them is using an interactive multimedia in the form of e-module or electronic module which uses Adobe Flash CS6 application. This research uses Research and Development (R&D method with which the combination between ADDIE procedure and Borg & Gall. It consists of 5 stages: (1 Analysis (Needs Analysis, (2 Design (Media of Learning, (3 Development (Media and Materials Validation, (4 Implementation (Small-scale and Field Try-Out, and Evaluation (Three times of revision. The e-module was validated by two experts for three times containing the early product, after small-scale try-out, and after field try-out. The results of the final validation are 99.31% for media expert validation, 98.61% for materials expert validation, and 90.03% for student validation. Abstrak: Perkembangan teknologi yang sangat pesat menghasilkan hal-hal baru, baik teknologi secara umum maupun perkembangan teknologi dalam dunia pendidikan. Perkembangan teknologi tersebut menuntut pendidik untuk mengembangkan pembelajaran yang inovatif. Salah satunya menggunakan multimedia interaktif yang dikemas dalam bentuk e-modul atau modul elektronik dengan memanfaatkan aplikasi Adobe Flash CS6. Penelitian ini menggunakan metode penelitian dan pengembangan (R&D dengan Prosedur penelitian dan pengembangan (R&D ADDIE yang digabungkan dengan Borg & Gall, meliputi 5 tahap yaitu: (1 Analisis (analisis kebutuhan, (2 Design (media pembelajaran, (3 Development (validasi media dan materi, (4 Implementasi (uji coba terbatas dan uji coba lapangan dan (5 Evaluasi (revisi tiga kali. E-modul ini divalidasi oleh dua validator sebanyak tiga kali, yaitu produk awal, setelah uji coba terbatas, dan setelah uji coba lapangan. Berikut adalah hasil yang diperoleh pada

  11. PENGEMBANGAN SSP TEMATIK INTEGRATIF UNTUK MEMBANGUN KARAKTER KEJUJURAN DAN KEPEDULIAN SISWA SD KELAS II

    Directory of Open Access Journals (Sweden)

    Sri Hariyati Qodriyah

    2015-07-01

    Full Text Available Penelitian ini bertujuan untuk menghasilkan perangkat pembelajaran berupa SSP Tematik yang dapat mengembangkan karakter siswa kelas 2 sekolah dasar, meliputi karakter kejujuran dan kepedulian. Penelitian ini merupakan penelitian dan pengembangan yang terdiri dari tujuh tahap, yaitu studi pendahuluan, perencanaan, mengembangkan produk awal, uji coba awal, revisi produk utama, uji coba lapangan, dan revisi terhadap produk operasional. SSP yang dikembangkan dievaluasi oleh seorang ahli materi dan media untuk mengetahui validitasnya. Subjek uji coba berjumlah 90 siswa terdiri dari 23 siswa SD Sonosewu, Kasihan, Bantul, DIY sebagai subjek uji coba terbatas dan 33 siswa untuk kelas control dan 34 siswa untuk kelas eksperimen SD 1 Kadipiro, Kasihan, Bantul, DIY. Hasil penelitian ini berupa SSP yang meliputi: silabus, RPP, LKS, dan lembar penilaian. Hasil evaluasi dari ahli materi dan ahli media untuk menguji tingkat kevalidan SSP menyatakan bahwa SSP yang dikembangkan adalah valid dan berkategori “baik”. Hasil uji coba menunjukkan bahwa SSP yang dikembangkan dinyatakan layak serta memenuhi kriteria praktis dan efektif dalam mengembangkan karakter siswa. Pembelajaran dengan SSP yang dikembangkan mampu mengembangkan karakter kejujuran dan kepedulian. Kata Kunci: SSP, karakter jujur dan peduli   DEVELOPING THEMATIC INTEGRATIVE SSP FOR BUILDING THE CHARACTERS OF HONESTY AND CARE GRADE II STUDENT OF ELEMENTARY SCHOOL Abstract This study aims to produce integrated learning sets in the form of thematic SSP that can develop the characters of honesty and care of grade II students of elementary school. This was a research and development study consisting of seven steps, i.e. preliminary study, planning, preliminary product development, preliminary tryout, main product revision, field tryout, revision of operational product, operational product revision, and revision of the final product. The developed SSP was evaluated by a science subject expert to assess

  12. Short Communication: Testosterone Measured with an Automatic Immunoassay Compares Reasonbly Well to Results Obtained by LC-MS/MS

    DEFF Research Database (Denmark)

    Knudsen, Cindy Søndersø; Højskov, Carsten Schriver; Møller, Holger Jon

    2016-01-01

    Background: Previous studies have reported problems measuring testosterone with immunological assays. Here we explore an automatic second generation immunoassay compared to a LC-MS/MS method. Methods: We collected blood samples from 76 women and measured testosterone, progesterone, gender...... hormonebinding globulin (SHBG), and albumin employing Cobas e601/c501. Testosterone, androstenedione (andro), dehydroepiandrosterone sulphate (DHEAS), and 17-hydroxyprogesterone (17-OHP) concentrations were measured employing LC-MS/MS. We evaluated the difference between testosterone measured by the two methods...... and examined the potential interference from the selected steroids and bindings proteins. Results: Testosterone concentrations measured by the two methods yielded: Cobas e601 = 1.240 x (LC-MS/MS) - 0.197, r = 0.84, for testosterone concentrations between 0.22 - 4.9 nmol/L. A positive correlation was observed...

  13. PENGEMBANGAN MEDIA PEMBELAJARAN PENDIDIKAN JASMANI OLAHRAGA DAN KESEHATAN BERBASIS KOMPUTER UNTUK SMA

    Directory of Open Access Journals (Sweden)

    Suci Cahyati

    2014-04-01

    Full Text Available Penelitian ini bertujuan untuk menghasilkan produk berupa CD pembelajaran pendidikan jasmani olahraga dan kesehatan berbasis komputer untuk SMA yang valid dan efektif. Penelitian ini menggunakan metode Research and Development (R&D. Media yang dikembangkan memuat materi tentang HIV/AIDS. Pengembangan media pembelajaran ini menggunakan software Adobe Flash Cs3 Professional. Media yang telah dikembangkan melalui dua tahap penelitiannya itu validasi ahli dan uji coba lapangan. Berdasarkan validasi ahli dan uji coba lapangan hasil penelitian menunjukkan produk termasuk kriteria “Sangat baik” dengan rerata skor 4,25. Hasil tes siswa mengalami peningkatan dari rerata skor pretest 5,53 dan rerata skor posttest 7,56. Berdasarkan hasil tes tersebut dapat disimpulkan bahwa media pembelajaran pendidikan jasmani olahraga dan kesehatan efektif digunakan dalam pembelajaran di SMA. Kata kunci: Pengembangan media, penjasorkes, SMA

  14. Magnetic bead/capture DNA/glucose-loaded nanoliposomes for amplifying the glucometer signal in the rapid screening of hepatitis C virus RNA.

    Science.gov (United States)

    Tu, Haijian; Lin, Kun; Lun, Yongzhi; Yu, Liuming

    2018-06-01

    A digital detection strategy based on a portable personal glucometer (PGM) was developed for the simple, rapid, and sensitive detection of hepatitis C virus (HCV) RNA, involving the release of glucose-loaded nanoliposomes due to coupling-site-specific cleavage by the endonuclease BamHI. The glucose-loaded nanoliposomes were synthesized using a reversed-phase evaporation method and provided an amplified signal at the PGM in the presence of HCV RNA. Initially, a 21-mer oligonucleotide complementary to HCV RNA was covalently conjugated to a magnetic bead through the amino group at the 5' end of the oligonucleotide, and then bound to a glucose-loaded liposome by typical carbodiimide coupling at its 3' end. In the presence of the target HCV RNA, the target hybridized with the oligonucleotide to form double-stranded DNA. The symmetrical duplex sequence 5'-GGATCC-3' between guanines was then catalytically cleaved by BamHI, which detached the glucose-loaded liposome from the magnetic bead. Following magnetic separation of the bead, the detached glucose-loaded liposome was lysed using Triton X-100 to release the glucose molecules within it, which were then detected as an amplified signal at the digital PGM. Under optimal conditions, the PGM signal increased with increasing HCV RNA, and displayed a strongly linear dependence on the level of HCV RNA for concentrations ranging from 10 pM to 1.0 μM. The detection limit (LOD) of the system was 1.9 pM. Good reproducibility and favorable specificity were achieved in the analysis of the target HCV RNA. Human serum samples containing HCV RNA were analyzed using this strategy, and the developed sensing platform was observed to yield satisfactory results based on a comparison with the corresponding results from a Cobas ® Amplicor HCV Test Analyzer. Graphical abstract A digital detection strategy utilizing a personal glucometer was developed for the detection of hepatitis C virus RNA. The strategy involved the use of the

  15. Interference of heparin in carcinoembryonic antigen radioimmunoassays

    International Nuclear Information System (INIS)

    Wu, J.T.

    1983-01-01

    A false Roche carcinoembryonic antigen (CEA) activity could be detected in all commercial and noncommercial heparin preparations examined. The possibility of 'due to contamination' has been ruled out. Using the Roche procedure, heparin solutions, in the absence of CEA, gave positive CEA activity; on the other hand, no CEA activity was detected in solutions containing only heparin when the Abbott Kit was used. When heparin was present in specimens containing CEA, the Abbott Kit underestimated the CEA activity, whereas the Roche Kit gave false elevated values. However, the negative effect of heparin could be reduced by heat treatment in the presence of plasma proteins. (Auth.)

  16. PERANGKAT LUNAK UNTUK EKTRAKSI ISI DOKUMEN MULTIFORMAT DENGAN MENGGUNAKAN SMS DAN FAXIMILE

    Directory of Open Access Journals (Sweden)

    Ahmad Hoirul Basori

    2005-01-01

    Full Text Available Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 Dokumen multiformat merupakan salah satu bentuk file yang disimpan dalam komputer  dan  banyak digunakan oleh  masyarakat saat ini.Setiap dokumen mempunyai karakteristik berbeda  dan memerlukan software yang berbeda untuk setiap file dokumen. Sedangkan perkembangan handphone yang semakin pesat membuat masyarakat lebih familiar menggunakan handphone daripada menggunakan komputer.proses pengambilan dokumen dapat terhambat jika user yang memerlukan dokumen multiformat tidak mempunyai keahlian komputer. Pada pengerjaan penelitian ini, teknologi yang digunakan untuk pengambilan dokumen multiformat adalah teknologi SMS dan mesin Faximile.sedangkan untuk pemodelan sistemnya teknologi yang digunakan adalah Unified Modelling Language dengan Rational Rose Enterprise 2000, serta  database Microsoft Access untuk penyimpanan data SMS. Untuk membangun aplikasi teknologi yang digunakan adalah Microsoft Visual Basic 6.0. Hal ini disebabkan dokumen multiformat pada penelitian ini kebanyakan merupakan produksi Microsoft sehingga antara teknologi yang digunakan dan dokumen multiformat saling mempunyai kesesuaian.   Uji coba dilakukan dengan cara melakukan pengiriman dokumen multiformat melalui SMS dan mengeluarkan outputnya ke dalam mesin faximile. Uji coba ini mencakup proses pembacaan data SMS, penyimpanan data SMS ke dalam database, pengiriman dokumen ke mesin fax, download page online, serta penambahan hak akses user melalui SMS. Hasil uji coba menunjukkan adanya permasalahan pada pengiriman dokumen multiformat yang berada dalam keadaan terproteksi. Permasalahan ini dapat diselesaikan dengan menghilangkan password yang ada pada dokumen multiformat.   Kata Kunci: SMS (Short Message Service, Ektraksi Dokumen, Mesin Fax.

  17. 12 Layout PPP adjusted.pmd

    African Journals Online (AJOL)

    Nubidga

    âge. Pan-africain et se caractérise par une association de roches plutoniques et volcaniques diversifiées. L'étude géochimique des éléments majeurs, des éléments traces et des terres rares montre l'appartenance des roches à la série ...

  18. Deoxynukleosidkinase aus insektenzellen zur Nukleosidmonophosphat synthese

    DEFF Research Database (Denmark)

    1998-01-01

    The patent application together with Roche on synthesis of monophosphate nucleotides by Dm-dNK, an enzyme isolated and the corresponding gene cloned in our laboratory.......The patent application together with Roche on synthesis of monophosphate nucleotides by Dm-dNK, an enzyme isolated and the corresponding gene cloned in our laboratory....

  19. Concordance in BRAF V600E status over time in malignant melanoma and corresponding metastases

    DEFF Research Database (Denmark)

    Nielsen, Line Bjerrehave; Dabrosin, Nina; Sloth, Karen

    2017-01-01

    of inter-tumour heterogeneity between the primary tumour and the corresponding metastases, time as a factor was also investigated. METHODS: In total, 227 samples from 224 melanoma patients were analysed using both the Cobas® 4800 BRAF V600 Mutation test and IHC anti-BRAF V600E staining. In 82 primary......AIMS: The present study analysed the usability of an immunohistochemical (IHC) analysis compared to a frequently used mutation detection analysis and examined the extent of intra- and inter-tumour heterogeneity of BRAF V600E in primary tumours and their corresponding metastases. In the development...... tumours and 224 corresponding metastases, the extent of inter- and intra-tumour heterogeneity was investigated using IHC staining. RESULTS: In 15 cases, disagreement between IHC analysis and the Cobas test was seen. In all but one of the examined patients, homogeneity between the primary tumour...

  20. Rheumatoid Case with HCV Infection

    OpenAIRE

    Bita Behnava; Seyed-Moayed Alavian

    2005-01-01

    Case Presentation:A 46-year-old woman referred to our center due to abnormality in aminotransferase level during check up. She had a history of blood transfusion 12 years ago. Anti-HCV Ab by ELISA method and HCV RNA by RT-PCR were positive. HCV RNA by Amplicor HCV monitor test counted 800,000 IU/ml and the genotype was 3a by Specific Primer-Targeted Region Core method. Laboratory evaluation revealed: Hb 11.9 mg/dl, WBC 5000 /ml, platelet count 190,000/ ml, ALT 70 IU/ml, AST 65 IU/ml, Alk phos...

  1. Influence of biological variations and sample handling on measured microalbuminuria in diabetic patients

    NARCIS (Netherlands)

    Vermes, I.; Spooren, P.F.M.J.

    1992-01-01

    Five immunochemical assays for determining low concentrations of albumin were investigated. These were a radioimmunoassay (RIA); turbidimetric immunoassays (TIA) both according to end-point measuring principle on a Cobas Fara and Hitachi 717 analysers, and according to kinetic measuring principle on

  2. MODEL PERMAINAN AKTIVITAS LUAR KELAS UNTUK MENGEMBANGKAN RANAH KOGNITIF, AFEKTIF, DAN PSIKOMOTORIK SISWA SMA

    Directory of Open Access Journals (Sweden)

    Hendra Setyawan

    2015-10-01

    Full Text Available Penelitian ini bertujuan menghasilkan model-model permainan Aktivitas Luar kelas (ALK yang layak digunakan sebagai materi pembelajaran penjas, serta efektif untuk mengembangkan ranah kognitif, afektif, dan psikomotorik siswa SMA. Penelitian ini dilakukan dengan langkah-langkah sebagai berikut: (1 pengumpulan informasi di lapangan, (2 menganalisis informasi yang telah dikumpulkan, (3 mengembangkan produk awal, (4 validasi ahli dan revisi, (5 uji coba skala kecil dan  revisi, (6 uji coba skala besar dan revisi, dan (7 pembuatan produk final. Uji coba skala kecil dilakukan terhadap siswa kelas X-D dan XI-IPA 4 dari SMA N I Prambanan berjumlah 66 orang. Uji coba skala besar dilakukan terhadap siswa kelas X-G, X-H, XI-IPS 3, dan XI-BHS dari SMA N I Prambanan berjumlah 132 orang. Instrumen pengumpulan data yang digunakan yaitu; (1 pedoman wawancara, (2 skala nilai, (3 pedoman observasi permainan, (4 pedoman observasi keefektifan permainan, (5 pedoman observasi terhadap guru pelaku uji coba, dan (6 rubrik penilaian siswa. Teknik analisis data dengan analisis deskriptif kuantitatif dan kualitatif. Hasil penelitian berupa tujuh model permainan yang layak dan efektif digunakan dalam pembelajaran penjas, hal ini dibuktikan dengan perolehan persentase sebesar 100% dari data hasil kuesioner skala nilai, observasi model permainan, observasi keefektifan permainan, dan observasi guru pelaku uji coba. Model permainan juga efektif untuk mengembangkan ranah kognitif, afektif, dan psikomotorik, yang dibuktikan dengan terjadinya peningkatan persentase nilai rata-rata siswa sebesar 21%. Kata kunci: model, permainan, aktivitas luar kelas, kognitif, afektif, psikomotorik THE OUTDOOR ACTIVITY GAME MODEL TO DEVELOP THE ASPECT OF COGNITIVE, AFFECTIVE, AND PSYCHOMOTOR OF THE SENIOR HIGH SCHOOL STUDENTS Abstract This study aims at producing outdoor activity game models which are proper to be used for physicall education learning and developing cognitive, affective, and

  3. PENGEMBANGAN MODEL PEMBELAJARAN MALCOLM’S MODELING UNTUK MENINGKATKAN KETERAMPILAN BERPIKIR KRITIS DAN MOTIVASI BELAJAR SISWA

    Directory of Open Access Journals (Sweden)

    Syarifah Syarifah

    2015-10-01

    Full Text Available Penelitian ini bertujuan untuk: (1 menghasilkan model pembelajaran fisika berbasis Malcom’s Modeling Method yang layak digunakan di sekolah, dan (2 mengetahui apakah model pembelajaran fisika berbasis Malcom’s Modeling Method dapat meningkatkan keterampilan berpikir kritis dan motivasi belajar siswa. Penelitian ini termasuk dalam ranah penelitian dan pengembangan (R&D. Prosedur pengembangan mengadaptasi dari prosedur pengembangan yang dikembangkan oleh Borg & Gall dengan langkah-langkah meliputi (1 penelitian dan pengumpulan data, (2 perencanaan, (3 pengembangan bentuk awal produk, (4 uji coba lapangan awal, (5 revisi hasil uji coba lapangan awal, (6 uji coba lapangan, (7 revisi hasil uji coba lapangan dan (8 diseminasi. Subjek uji coba lapangan awal terdiri atas 36 siswa kelas X MIA 6 di SMA N 7 Yogyakarta. Subjek uji coba lapangan pada kelas ekperimen terdiri atas 36 orang siswa kelas X MIA 1 dan pada kelas kontrol terdiri atas 34 orang siswa kelas X MIA 5 di SMA N 7 Yogyakarta. Instrumen pengumpulan data menggunakan soal untuk mengukur keterampilan berpikir kritis, angket untuk mengukur motivasi belajar, angket respon siswa dan lembar observasi keterlaksanaan pembelajaran. Teknik analisis data menggunakan uji MANOVA dengan taraf signifikansi 5%. Hasil penelitian menunjukkan bahwa model Malcom’s Modeling Method ditinjau dari sintaks, sistem sosial, prinsip reaksi, sistem pendukung dan dampak instruksional dan pengiring layak digunakan di sekolah dengan kategori sangat baik. Hasil uji MANOVA menunjukkan model Malcom’s Modeling Method dapat meningkatkan keterampilan berpikir kritis dan motivasi belajar siswa pada taraf signifikansi 5 %. Kata Kunci: Malcom’s Modeling Method, keterampilan berpikir kritis, motivasi belajar.   DEVELOPING A PHYSICS INSTRUCTION MODEL BASED ON MALCOLM’S MODELING TO IMPROVE CRITICAL THINKING SKILLS AND LEARNING MOTIVATION Abstract This research aims to (1 develop a physics instruction model based on

  4. Analytic performance studies and clinical reproducibility of a real-time PCR assay for the detection of epidermal growth factor receptor gene mutations in formalin-fixed paraffin-embedded tissue specimens of non-small cell lung cancer

    International Nuclear Information System (INIS)

    O’Donnell, Patrick; Shieh, Felice; Wei, Wen; Lawrence, H Jeffrey; Wu, Lin; Schilling, Robert; Bloom, Kenneth; Maltzman, Warren; Anderson, Steven; Soviero, Stephen; Ferguson, Jane; Shyu, Johnny; Current, Robert; Rehage, Taraneh; Tsai, Julie; Christensen, Mari; Tran, Ha Bich; Chien, Sean Shih-Chang

    2013-01-01

    Epidermal growth factor receptor (EGFR) gene mutations identify patients with non-small cell lung cancer (NSCLC) who have a high likelihood of benefiting from treatment with anti-EGFR tyrosine kinase inhibitors. Sanger sequencing is widely used for mutation detection but can be technically challenging, resulting in longer turn-around-time, with limited sensitivity for low levels of mutations. This manuscript details the technical performance verification studies and external clinical reproducibility studies of the cobas EGFR Mutation Test, a rapid multiplex real-time PCR assay designed to detect 41 mutations in exons 18, 19, 20 and 21. The assay’s limit of detection was determined using 25 formalin-fixed paraffin-embedded tissue (FFPET)-derived and plasmid DNA blends. Assay performance for a panel of 201 specimens was compared against Sanger sequencing with resolution of discordant specimens by quantitative massively parallel pyrosequencing (MPP). Internal and external reproducibility was assessed using specimens tested in duplicate by different operators, using different reagent lots, instruments and at different sites. The effects on the performance of the cobas EGFR test of endogenous substances and nine therapeutic drugs were evaluated in ten FFPET specimens. Other tests included an evaluation of the effects of necrosis, micro-organisms and homologous DNA sequences on assay performance, and the inclusivity of the assay for less frequent mutations. A >95% hit rate was obtained in blends with >5% mutant alleles, as determined by MPP analysis, at a total DNA input of 150 ng. The overall percent agreement between Sanger sequencing and the cobas test was 96.7% (negative percent agreement 97.5%; positive percent agreement 95.8%). Assay repeatability was 98% when tested with two operators, instruments, and reagent lots. In the external reproducibility study, the agreement was > 99% across all sites, all operators and all reagent lots for 11/12 tumors tested. Test

  5. Pemanfaatan Augmented Reality Pada Permainan Othello

    Directory of Open Access Journals (Sweden)

    Rendy Layman Aguston

    2016-11-01

    Full Text Available Perkembangan teknologi telah mengubah cara pengerjaan suatu pekerjaan dari cara konvensional menjadi cara yang lebih praktis. Dengan hadirnya teknologi Augmented Reality, cara bermain yang menggunakan pion dan membalikkan pion musuh secara manual menjadi lebih mudah dalam memainkan permainan selain juga dapat berinteraksi langsung. Pembuatan permainan Othello menggunakan program Unity dengan framework Vuforia untuk mewujudkan Augmented Reality pada permainan Othello. Untuk menerapkan Augmented Reality dengan baik, dibutuhkan papan permainan sebagai image target yang sesuai dengan kriteria, jenis kamera yang digunakan, jarak kamera terhadap papan permainan, intensitas cahaya yang ditangkap kamera, serta tingkat sensitivitas tombol virtual. Pada permainan Othello ini tersedia fitur komputer yang menggunakan algoritma Alpha Beta Pruning dengan 3 level kedalaman yang menggunakan perhitungan fungsi evaluasi berupa mobility, potential mobility dan penguasaan corner yang menghasilkan kemenangan mencapai 73,33% dari 15 kali uji coba terhadap aplikasi Othello serupa dan 78,34% dari 37 kali uji coba terhadap user.

  6. Application de la méthode de balayage d'activité de processus ...

    African Journals Online (AJOL)

    AKA Boko

    performances de la carrière de « Ben Azzouz » en optimisant le nombre de camions nécessaires et les délais de .... le transport de la roche vers le concasseur primaire, le concassage de la roche pour produire le granulat. ..... VARIABLE. MaxLoadedHoles (Maximum de trou pouvant être chargé) nHolesPerShot. VARIABLE.

  7. Possible mechanism for mass transfer in X-ray binary systems with OB supergiant companions

    International Nuclear Information System (INIS)

    Alme, M.L.; Wilson, J.R.

    1976-01-01

    We have studied the ''beginning Roche lobe overflow'' phase of mass transfer. We find that before the primary fills its Roche lobe, radiation-driven density waves generated in the atmosphere produce a sufficient mass outflow rate to power a compact X-ray source. In particular, for a model of Cygnus X-1, if the radius of the photosphere is between 82 and 86 percent of the radius of the Roche equipotential, large-amplitude density waves with irregular periods of a few days are observed. These density waves, which are generated by radiation pressure effects, pass through the inner Lagrangian point with velocities approx.100 km s -1 , and can easily provide sufficient material to power the compact X-ray source

  8. Enzymatic assay for methotrexate in erythrocytes

    DEFF Research Database (Denmark)

    Schrøder, H; Heinsvig, E M

    1985-01-01

    Methotrexate (MTX) accumulates in erythrocytes in MTX-treated patients. We present a modified enzymatic assay measuring MTX concentrations between 10 and 60 nmol/l in erythrocytes, adapted for a centrifugal analyser (Cobas Bio). About 40 patient's samples could be analysed within 1 h. The detection...

  9. Validation of a norovirus multiplex real-time RT-PCR assay for the detection of norovirus GI and GII from faeces samples.

    LENUS (Irish Health Repository)

    Jones, S

    2011-01-01

    Norovirus is a leading cause of infectious non-bacterial gastroenteritis. The virus is highly contagious and has multiple modes of transmission, presenting a growing challenge to hospital-based healthcare. In this study, a total of 120 stool samples are tested for the presence of norovirus GI and GII by the Roche two-step Lightcycler 2.0 assay incorporating primers and probes produced by TIB Molbiol, and the results are compared with results from the National Virus Reference Laboratory. The Roche\\/TIB Molbiol assay produced 51 positive results and 69 negative results. Discrepancy analysis was performed for six conflicting results using a second real-time polymerase chain reaction (PCR) assay (Roche\\/TIB Molbiol) and this confirmed that four of the five discrepant positive results were true positives. A single discrepant negative result generated by the Roche assay remained negative using the second assay. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated to be 98%, 98.6%, 98.0% and 98.6%, respectively. Melting curve analysis was used to differentiate genogroups I and II and this showed that 92% of strains belonged to genogroup II.

  10. De geologie van den Cimone di Margno en den Monte di Muggio

    NARCIS (Netherlands)

    Buning, W.L.

    1931-01-01

    Le terrain étudié (fig. 1) est formé de roches métamorphiques pour plus de la moitié; le reste est formé de sédiments variant du Permien au Trias Inférieur, et de roches appartenant à la culmination éruptivocristalline du Cimone di Margno. Le relief du paysage présente en général des pentes douces.

  11. A daunting challenge

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Bonde, Jesper; Ejegod, Ditte

    2015-01-01

    We compared cytology with Hybrid Capture 2 (HC2), cobas, CLART and APTIMA Human Papillomavirus (HPV) assays in primary cervical screening at age 23-29 years based on data from the Danish Horizon study. SurePath samples were collected from 1278 women undergoing routine cytology-based screening...

  12. Comparison of two commercial assays for detection of human papillomavirus (HPV) in cervical scrape specimens: validation of the Roche AMPLICOR HPV test as a means to screen for HPV genotypes associated with a higher risk of cervical disorders.

    NARCIS (Netherlands)

    Ham, M.A.P.C. van; Bakkers, J.M.J.E.; Harbers, G.; Quint, W.G.V.; Massuger, L.F.A.G.; Melchers, W.J.G.

    2005-01-01

    Certain high-risk (HR) human papillomavirus (HPV) types are a necessary cause for the development of cervical disorders. Women with persistent HR HPV infections have an increased risk of developing high-grade cervical lesions, compared with those who have no or low-risk HPV infections. Therefore,

  13. Rancang Bangun Permainan Edukasi Matematika dan Fisika dengan Memanfaatkan Accelerometer dan Physics Engine Box2d pada Android

    Directory of Open Access Journals (Sweden)

    Putri Nikensasi

    2012-09-01

    Full Text Available Perkembangan industri permainan mobil yang semakin meningkat memotivasi para pengembang permainan mobil untuk membuat inovasi-inovasi terbaru dalam permainannya. Salah satu inovasi tersebut yaitu permainan edukasi, namun saat ini permainan edukasi kurang diminati karena aturan permainannya yang cenderung membosankan. Pengembangan permainan ini ditujukan untuk membuat sebuah permainan mobil edukasi dengan memanfaatkan teknologi mobil terbaru dalam aturan permainannya sehingga permainan tersebut tidak membosankan. Aplikasi yang dikembangkan merupakan aplikasi permainan mobil edukasi yang mengajarkan ilmu matematika dan fisika kepada pemainnya. Teknologi baru yang digunakan dalam permainan ini yaitu accelerometer pada sistem operasi Android yang diintegrasikan dengan Physics Engine Library Box2D. Selain itu, permainan ini dibangun dengan menggunakan Adobe Flash CS5.5 dan bahasa pemrograman Actionscript 3 (AS3 serta Adobe Air sebagai runtime aplikasinya. Uji coba dilakukan dengan menggunakan perangkat Android versi 2.3. Dari uji coba dapat disimpulkan bahwa Adobe Flash CS5.5 dapat digunakan untuk membuat permainan mobil edukasi pada perangkat Android dan mengakses sensor accelerometer-nya.

  14. Implementasi Algoritma Particle Swarm untuk Menyelesaikan Sistem Persamaan Nonlinear

    Directory of Open Access Journals (Sweden)

    Ardiana Rosita

    2012-09-01

    Full Text Available Penyelesaian sistem persamaan nonlinear merupakan salah satu permasalahan yang sulit pada komputasi numerik dan berbagai aplikasi teknik. Beberapa metode telah dikembangkan untuk menyelesaikan sistem persamaan ini dan metode Newton merupakan metode yang paling sering digunakan. Namun metode ini memerlukan perkiraan solusi awal dan memilih perkiraan solusi awal yang baik untuk sebagian besar sistem persamaan nonlinear tidaklah mudah. Pada makalah ini, algoritma Particle Swarm yang diusulkan oleh Jaberipour dan kawan-kawan[1] diimplementasikan. Algoritma ini merupakan pengembangan dari algoritma Particle Swarm Optimization (PSO. Algoritma ini meyelesaikan sistem persamaan nonlinear yang sebelumnya telah diubah menjadi permasalahan optimasi. Uji coba dilakukan terhadap beberapa fungsi dan sistem persamaan nonlinear untuk menguji kinerja dan efisiensi algoritma. Berdasarkan hasil uji coba, beberapa fungsi dan sistem persamaan nonlinear telah konvergen pada iterasi ke 10 sampai 20 dan terdapat fungsi yang konvergen pada iterasi ke 200. Selain itu, solusi yang dihasilkan algoritma Particle Swarm mendekati solusi eksak.

  15. First Zika-positive donations in the continental United States.

    Science.gov (United States)

    Galel, Susan A; Williamson, Phillip C; Busch, Michael P; Stanek, Danielle; Bakkour, Sonia; Stone, Mars; Lu, Kai; Jones, Scott; Rossmann, Susan N; Pate, Lisa Lee

    2017-03-01

    Zika virus (ZIKV) has spread in the Americas, including parts of the southern United States, and infection can be associated with serious complications, including congenital brain abnormalities. Probable transfusion transmission of ZIKV has been documented in Brazil. Preemptive testing of blood donations for ZIKV RNA was implemented in southern US states at risk of local transmission using a test approved under a Food and Drug Administration (FDA) investigational new drug application, cobas Zika. Screening was expanded after issuance of an updated FDA guidance. Donations reactive on initial screening were further tested by nucleic acid and antibody tests to determine the donor status. Of 358,786 donations from US states screened by individual donation testing, 23 were initially reactive on cobas Zika. Fourteen of these represented probable ZIKV infection based on reactivity on additional nucleic acid testing or anti-Zika immunoglobulin M. Ten of the 14 donors reported travel to an identified ZIKV-active area within 90 days before donation (median time from end of travel to donation, 25 days; range, 6-71 days). Three donors with travel history also had a potential sexual exposure. Only seven of the 14 donations with probable ZIKV infection were detectable upon 1:6 dilution to simulate minipool testing. The estimated specificity of the cobas Zika test was 99.997%. Screening of donations for ZIKV RNA can interdict ZIKV-infected donors. Donor risk factors include travel more than 4 weeks before donation and sexual exposure. Minipool screening would have detected only 50% of the RNA-positive donations. © 2017 The Authors Transfusion published by Wiley Periodicals, Inc. on behalf of AABB.

  16. Feasibility and accuracy evaluation of three human papillomavirus assays for FTA card-based sampling: a pilot study in cervical cancer screening.

    Science.gov (United States)

    Wang, Shao-Ming; Hu, Shang-Ying; Chen, Wen; Chen, Feng; Zhao, Fang-Hui; He, Wei; Ma, Xin-Ming; Zhang, Yu-Qing; Wang, Jian; Sivasubramaniam, Priya; Qiao, You-Lin

    2015-11-04

    Liquid-state specimen carriers are inadequate for sample transportation in large-scale screening projects in low-resource settings, which necessitates the exploration of novel non-hazardous solid-state alternatives. Studies investigating the feasibility and accuracy of a solid-state human papillomavirus (HPV) sampling medium in combination with different down-stream HPV DNA assays for cervical cancer screening are needed. We collected two cervical specimens from 396 women, aged 25-65 years, who were enrolled in a cervical cancer screening trial. One sample was stored using DCM preservative solution and the other was applied to a Whatman Indicating FTA Elute® card (FTA card). All specimens were processed using three HPV testing methods, including Hybrid capture 2 (HC2), careHPV™, and Cobas®4800 tests. All the women underwent a rigorous colposcopic evaluation that included using a microbiopsy protocol. Compared to the liquid-based carrier, the FTA card demonstrated comparable sensitivity for detecting high grade Cervical Intraepithelial Neoplasia (CIN) using HC2 (91.7 %), careHPV™ (83.3 %), and Cobas®4800 (91.7 %) tests. Moreover, the FTA card showed a higher specificity compared to a liquid-based carrier for HC2 (79.5 % vs. 71.6 %, P = 0.015), comparable specificity for careHPV™ (78.1 % vs. 73.0 %, P > 0.05), but lower specificity for the Cobas®4800 test (62.4 % vs. 69.9 %, P = 0.032). Generally, the FTA card-based sampling medium's accuracy was comparable with that of liquid-based medium for the three HPV testing assays. FTA cards are a promising sample carrier for cervical cancer screening. With further optimization, it can be utilized for HPV testing in areas of varying economic development.

  17. Les Basaltes de l’Atlas de Béni-Mellal (Haut Atlas Central, Maroc : un Volcanisme Transitionnel Intraplaque Associé aux Stades de L’évolution Géodynamique du Domaine Atlasique

    Directory of Open Access Journals (Sweden)

    Jaouad Guezal

    2013-07-01

    Full Text Available Les roches basaltiques de l’Atlas de Béni-Mellal (Haut-Atlas Central, Maroc, mises en place, dans les différents bassins synclinaux de la région, se manifestent en deux horizons volcaniques B1 et B2. Les deux événements éruptifs sont d’âge Jurassique moyen pour les coulées de l’horizon B1 et d’âge Crétacé inférieur pour celles de l’horizon B2. Les roches sont caractérisées par un faciès des basaltes à olivines. La composition de leurs clinopyroxènes est marquée par deux tendances : augite au niveau des basaltes à olivine du B1 et diopside au niveau de ceux du B2. La composition géochimique sur roche totale dévoile le caractère transitionnel de ces roches. La relative dissimilitude géochimique signalée au niveau des basaltes des deux horizons peut être expliquée par un début du changement de la nature du magmatisme de la région en relation avec l’évolution géodynamique du domaine atlasique.

  18. Randomized comparison of vaginal self-sampling by standard vs. dry swabs for Human papillomavirus testing

    International Nuclear Information System (INIS)

    Eperon, Isabelle; Vassilakos, Pierre; Navarria, Isabelle; Menoud, Pierre-Alain; Gauthier, Aude; Pache, Jean-Claude; Boulvain, Michel; Untiet, Sarah; Petignat, Patrick

    2013-01-01

    To evaluate if human papillomavirus (HPV) self-sampling (Self-HPV) using a dry vaginal swab is a valid alternative for HPV testing. Women attending colposcopy clinic were recruited to collect two consecutive Self-HPV samples: a Self-HPV using a dry swab (S-DRY) and a Self-HPV using a standard wet transport medium (S-WET). These samples were analyzed for HPV using real time PCR (Roche Cobas). Participants were randomized to determine the order of the tests. Questionnaires assessing preferences and acceptability for both tests were conducted. Subsequently, women were invited for colposcopic examination; a physician collected a cervical sample (physician-sampling) with a broom-type device and placed it into a liquid-based cytology medium. Specimens were then processed for the production of cytology slides and a Hybrid Capture HPV DNA test (Qiagen) was performed from the residual liquid. Biopsies were performed if indicated. Unweighted kappa statistics (κ) and McNemar tests were used to measure the agreement among the sampling methods. A total of 120 women were randomized. Overall HPV prevalence was 68.7% (95% Confidence Interval (CI) 59.3–77.2) by S-WET, 54.4% (95% CI 44.8–63.9) by S-DRY and 53.8% (95% CI 43.8–63.7) by HC. Among paired samples (S-WET and S-DRY), the overall agreement was good (85.7%; 95% CI 77.8–91.6) and the κ was substantial (0.70; 95% CI 0.57-0.70). The proportion of positive type-specific HPV agreement was also good (77.3%; 95% CI 68.2-84.9). No differences in sensitivity for cervical intraepithelial neoplasia grade one (CIN1) or worse between the two Self-HPV tests were observed. Women reported the two Self-HPV tests as highly acceptable. Self-HPV using dry swab transfer does not appear to compromise specimen integrity. Further study in a large screening population is needed. ClinicalTrials.gov: http://clinicaltrials.gov/show/NCT01316120

  19. Detección molecular del virus papiloma humano de alto riesgo oncogénico en muestras cervicales. Laboratorio Central de Salud Pública. Primeros Resultados

    Directory of Open Access Journals (Sweden)

    Maria Liz Bobadilla

    2015-04-01

    Full Text Available El cáncer de cuello uterino es la primera causa de muerte por cáncer en mujeres en países en vías de desarrollo, con una tasa de incidencia de 34,2 por 100.000 mujeres y de mortalidad de 15,7 por 100.000 mujeres en Paraguay. La sensibilidad de la citología está entre 30-60%, mientras que la de la detección molecular del Virus Papiloma Humano (VPH en muestras cervicales, es mayor al 90% para detectar neoplasia intraepitelial cervical de grado 2 (CIN II o más. El objetivo de este trabajo fue describir la frecuencia de detección de VPH de alto riesgo (AR y su distribución por edad en mujeres que concurrieron al Hospital San Pablo, de mayo a agosto de 2.013. Se estudiaron 170 muestras cervicales de pacientes que accedieron a participar firmando un consentimiento informado. Se utilizó el sistema Cobas 4800 HPV Test (Roche que detecta los VPH-AR 16 y 18, y un pool de 10 VPH-AR (31,33,35,39,45,51,52,56,58,59 y dos de “probable” alto riesgo (66,68. La frecuencia de infección por VPH-AR fue del 16%, la infección decrecía con la edad y el mayor número de casos apareció en mujeres menores de 30 años. El VPH-16 fue encontrado en todos los grupos de edades. Este es el primer reporte de la detección de ADN de VPH-AR en el LCSP, y se muestra que la prevención y control del cáncer cérvico-uterino es una prioridad de salud pública en el país por la gran carga de la enfermedad evidenciada por su alta incidencia y mortalidad.

  20. Options to Expand HIV Viral Load Testing in South Africa: Evaluation of the GeneXpert® HIV-1 Viral Load Assay.

    Directory of Open Access Journals (Sweden)

    Natasha Gous

    Full Text Available Expansion of HIV viral load (VL testing services are required to meet increased targets for monitoring patients on antiretroviral treatment. South Africa currently tests >4million VLs per annum in 16 highly centralised, automated high-throughput laboratories. The Xpert HIV-1 VL assay (Cepheid was evaluated against in-country predicates, the Roche Cobas Taqmanv2 and Abbott HIV-1RT, to investigate options for expanding VL testing using GeneXpert's random access, polyvalent capabilities and already established footprint in South Africa with the Xpert MTB/RIF assay (207 sites. Additionally, the performance of Xpert HIV-1VL on alternative, off-label specimen types, Dried Blood Spots (DBS and whole blood, was investigated.Precision, accuracy (agreement and clinical misclassification (1000cp/ml of Xpert HIV-1VL plasma was compared to Taqmanv2 (n = 155 and Abbott HIV-1 RT (n = 145. Misclassification of Xpert HIV-1VL was further tested on DBS (n = 145 and whole blood (n = 147.Xpert HIV-1VL demonstrated 100% concordance with predicate platforms on a standardised frozen, plasma panel (n = 42 and low overall percentage similarity CV of 1.5% and 0.9% compared to Taqmanv2 and Abbott HIV-1 RT, respectively. On paired plasma clinical specimens, Xpert HIV-1VL had low bias (SD 0.32-0.37logcp/ml and 3% misclassification at the 1000cp/ml threshold compared to Taqmanv2 (fresh and Abbott HIV-1 RT (frozen, respectively. Xpert HIV-1VL on whole blood and DBS increased misclassification (upward by up to 14% with increased invalid rate. All specimen testing was easy to perform and compatible with concurrent Xpert MTB/RIF Tuberculosis testing on the same instrument.The Xpert HIV-1VL on plasma can be used interchangeably with existing predicate platforms in South Africa. Whole blood and DBS testing requires further investigation, but polyvalency of the GeneXpert offers a solution to extending VL testing services.

  1. High-risk papillomavirus infection among women living with human Immunodeficiency virus: Brazilian multicentric study.

    Science.gov (United States)

    Miranda, Angelica E; Silveira, Mariangela F; Travassos, Ana G; Tenório, Teresinha; Val, Isabel C C; Lannoy, Leonor; Mattos Junior, Hortensio S; Carvalho, Newton S

    2017-12-01

    Cervical cancer is an important health issue in Latin America. Although HPV infections can have spontaneous clearance, persistence of high-risk (HR) HPV is a risk factor for cervical cancer among women and it is even higher in HIV-infected women. To determine the prevalence of HR-HPV and risk factors among HIV-infected women attending reference services for HIV/AIDS in different regions of Brazil. Cross-sectional study conducted among HIV-infected women attended at referral care centers for HIV/AIDS in nine states of Brazil. Women from 18 to 49 years that accept to participate and were not pregnant at the time of the approach were recruited for the study. The HPV screening was realized using qPCR in closed system, in vitro Diagnostic, COBAS ® -HPV Roche. The cytology results were available by the Bethesda System. A total of 802(89.1%) from the selected women agreed to participate in the study. Median age was 39(Inter quartile range [IQR34-46]) years and median education was 9(IQR6-11) years. General prevalence of HR-HPV was 28.4%(228/802). HPV-16 prevalence rate was 8.1%(65/802), HPV-18 was 3.7%(30/802) and other types of HR-HPV were 23.6% (189/802). Risk factors for HR-HPV infection in the multivariate logistic regression analysis were: age ranging from 18 to 34 years (OR = 1.43[95%CI:1.18-1.75]), illicit drugs use (OR = 1.61[95%CI:1.10-2.42]) and abnormal cervical cytology (OR = 1.56[95%CI:1.34-1.81]). Results showed a prevalence rate of 28.4% of HR-HPV infection in women living with HIV in Brazil. These infections were significantly associated with having less than 35 years old, illicit drug use and abnormal cervical cytology. © 2017 Wiley Periodicals, Inc.

  2. Application of a newly developed high-sensitivity HBsAg chemiluminescent enzyme immunoassay for hepatitis B patients with HBsAg seroclearance.

    Science.gov (United States)

    Shinkai, Noboru; Matsuura, Kentaro; Sugauchi, Fuminaka; Watanabe, Tsunamasa; Murakami, Shuko; Iio, Etsuko; Ogawa, Shintaro; Nojiri, Shunsuke; Joh, Takashi; Tanaka, Yasuhito

    2013-11-01

    We modified and automated a highly sensitive chemiluminescent enzyme immunoassay (CLEIA) for surface antigen (HBsAg) detection using a combination of monoclonal antibodies, each for a specific epitope of HBsAg, and by improving an earlier conjugation technique. Of 471 hepatitis B virus (HBV) carriers seen in our hospital between 2009 and 2012, 26 were HBsAg seronegative as determined by the Abbott Architect assay. The Lumipulse HBsAg-HQ assay was used to recheck those 26 patients who demonstrated seroclearance by the Abbott Architect assay. The performance of the Lumipulse HBsAg-HQ assay was compared with that of a quantitative HBsAg detection system (Abbott Architect) and the Roche Cobas TaqMan HBV DNA assay (CTM) (lower limit of detection, 2.1 log copies/ml) using blood serum samples from patients who were determined to be HBsAg seronegative by the Abbott Architect assay. Ten patients had spontaneous HBsAg loss. Of 8 patients treated with nucleotide analogues (NAs), two were HBsAg seronegative after stopping lamivudine therapy and 6 were HBsAg seronegative during entecavir therapy. Eight acute hepatitis B (AH) patients became HBsAg seronegative. Of the 26 patients, 16 were HBsAg positive by the Lumipulse HBsAg-HQ assay but negative by the Abbott Architect assay. The differences between the two assays in terms of detectable HBsAg persisted over the long term in the spontaneous loss group (median, 10 months), the NA-treated group (2.5 months), and the AH group (0.5 months). In 9 patients, the Lumipulse HBsAg-HQ assay detected HBsAg when HBV DNA was negative by the CTM assay. HBsAg was also detected by the Lumipulse HBsAg-HQ assay in 4 patients with an anti-HBs concentration of >10 mIU/ml, 3 of whom had no HBsAg escape mutations. The automatic, highly sensitive HBsAg CLEIA Lumipulse HBsAg-HQ is a convenient and precise assay for HBV monitoring.

  3. The role of intrа- and postoperative ACTH and cortisol levels measurement in patients with Cushing’s disease as an early predictors of remission

    Directory of Open Access Journals (Sweden)

    Elena Y. Nadezhdina

    2017-07-01

    Full Text Available Objectives. The aim of this research was to study the dynamic changes of intra- and early postoperative hormonal parameters (ACTH and cortisol as predictors of hypercorticism remission. Material and methods. 50 patients with confirmed Cushing`s disease (CD were sampled for this research. The patients were divided into 3 groups depending on the outcome of the operation. The first group – patients with secondary adrenal insufficiency confirmed by clinical picture and the level of cortisol less than 50 nmol/l; the second group – with normalization of levels of ACTH and cortisol; the third – with the persistence of the CD. The results of intraoperative studies during the transnasal adenomectomy were then studied. The group sample consisted of 38 women and 12 men, aged 15–66 years. To assess the levels of ACTH and cortisol blood sampling was performed from a peripheral vein. The first sample was taken during the incision of the Dura mater, the second – immediately after removal of the tumor and the last – 20 minutes after the removal of the adenoma. Then, 1 day after the surgery the hormones mentioned above were studied in all patients. The levels of ACTH and cortisol were measured by immunochemiluminescent analysis on the automated system Cobas 6000 (Roche, France. Reference intervals ACTH 0–30 ng/ml, cortisol123–626 nmol/l. Results. The analysis of the obtained data did not suggest a relationship between the changes of intraoperative indicators of hormonal status and the likelihood of disease remission (p > 0.125. In the postoperative period, of the 50 patients, 41 (82% developed adrenal insufficiency, 5 (10% showed normalization and in 4 patients (8% adrenal insufficiency was not observed. The results of the hormonal research after 1 day had a correlation with the frequency of postoperative remission (p < 0.125. Conclusion. Intraoperative measurement of levels of ACTH and cortisol is not appropriate and cannot serve as guidance for

  4. Performance of two updated blood glucose monitoring systems: an evaluation following ISO 15197:2013.

    Science.gov (United States)

    Pleus, Stefan; Baumstark, Annette; Rittmeyer, Delia; Jendrike, Nina; Haug, Cornelia; Freckmann, Guido

    2016-05-01

    Objective For patients with diabetes, regular self-monitoring of blood glucose (SMBG) is essential to ensure adequate glycemic control. Therefore, accurate and reliable blood glucose measurements with SMBG systems are necessary. The international standard ISO 15197 describes requirements for SMBG systems, such as limits within which 95% of glucose results have to fall to reach acceptable system accuracy. The 2013 version of this standard sets higher demands, especially regarding system accuracy, than the currently still valid edition. ISO 15197 can be applied by manufacturers to receive a CE mark for their system. Research design and methods This study was an accuracy evaluation following ISO 15197:2013 section 6.3 of two recently updated SMBG systems (Contour * and Contour TS; Bayer Consumer Care AG, Basel, Switzerland) with an improved algorithm to investigate whether the systems fulfill the requirements of the new standard. For this purpose, capillary blood samples of approximately 100 participants were measured with three test strip lots of both systems and deviations from glucose values obtained with a hexokinase-based comparison method (Cobas Integra † 400 plus; Roche Instrument Center, Rotkreuz, Switzerland) were determined. Percentages of values within the acceptance criteria of ISO 15197:2013 were calculated. This study was registered at clinicaltrials.gov (NCT02358408). Main outcome Both updated systems fulfilled the system accuracy requirements of ISO 15197:2013 as 98.5% to 100% of the results were within the stipulated limits. Furthermore, all results were within the clinically non-critical zones A and B of the consensus error grid for type 1 diabetes. Conclusions The technical improvement of the systems ensured compliance with ISO 15197 in the hands of healthcare professionals even in its more stringent 2013 version. Alternative presentation of system accuracy results in radar plots provides additional information with certain advantages. In addition

  5. A Reverse-phase Protein Microarray-based Screen Identifies Host Signaling Dynamics upon Burkholderia spp. Infection

    Science.gov (United States)

    2015-07-27

    total protein in each sample was quantified by Bradford assay (Bio-Rad). RAW264.7 cell lysate preparations were boiled for 10 min with NuPAGE LDS Sample...RPMA assays , cells were harvested, washed with PBS, and then lysed in a mixture of T-PER Reagent (Thermo Scientific) and 2X Tris-Glycine SDS sample... assay (RIPA) buffer (Thermo Scientific) containing complete protease inhibitor cocktail (Roche), and phosphatase inhibitors (Roche). The amount of

  6. Referral population studies underestimate differences between human papillomavirus assays in primary cervical screening

    DEFF Research Database (Denmark)

    Rebolj, M.; Njor, S.; Lynge, E.

    2017-01-01

    with SurePath® cytology, and Hybrid Capture 2 (HC2), cobas, CLART and APTIMA HPV assays. Women with positive test results were offered a follow-up. For all detected HPV infections and HPV-positive high-grade cervical intraepithelial neoplasia (≥CIN2), we studied the distributions of assay-specific signal...

  7. Real-time ed end-point Polymerase Chain Reaction per la quantizzazione del DNA di Citomegalovirus: confronto tra metodi e con il test per l’antigene pp65

    Directory of Open Access Journals (Sweden)

    Tiziano Allice

    2006-03-01

    Full Text Available Quantitave Polymerase Chain Reaction (PCR for Cytomegalovirus (CMV DNA provides highly sensitive and specific data for detecting CMV as well as monitoring the infection and determining the appropriate antiviral strategy.To determine the clinical application of a recently introduced real-time (RT PCR assay for CMV DNA quantitation in peripheral blood leukocytes (PBLs and defining its correlation with the commercial quantitative end-point (EP PCR method COBAS AMPLICOR CMV Monitor and pp65 antigen test. Sequential PBL samples (n=158 from 32 liver transplanted patients with CMV asymptomatic infection and positive for CMV DNA by EP-PCR were retrospectively analysed with RT-PCR and studied according to pp65 antigen levels. A good correlation was found between RT-PCR and pp65 antigen test (r=0.691 and between the two PCR assays (r=0.761. RT-PCR data were significantly higher in pre-emptive treated patients (those with >20 pp65+positive cells, median value: 3.8 log10 copies/500,000 PBLs than in not-treated ones (2.9 logs.According to pp65 levels of 0, 1-10, 11-20, 21-50, 51-100 and >100 positive cells/200,000 PBLs, median CMV DNA load by RT-PCR was 2.6, 3.0, 3.6, 4.0. 4.2 and 4.8, log10 copies/ 500,000 PBLs, respectively (EP-PCR CMV DNA levels: 2. 8, 2.9, 3.8, 3.7, 3.9 and 4.0 logs. For samples with >20 pp65+cells, that is above the level at which pre-emptive therapy was started, RT-PCR values were significantly higher than in groups with less than 20 pp65+cells, whereas EP-PCR values did not significantly differ and showed a slower progression rate. Dilutions of DNA from CMV AD169 strain were used to probe RT-PCR reproducibility (between and intra-assay variability < 2% and sensitivity (100% detection rate at 10 copies/reaction, 28.5% with EP-PCR. A significant improvement is coming from the introduction of RT-PCR to the study of CMV DNA dynamics in differently CMV infected patients due to a more reliable quantitation of CMV DNA for moderate and high

  8. Verification of the harmonization of human epididymis protein 4 assays.

    Science.gov (United States)

    Ferraro, Simona; Borille, Simona; Carnevale, Assunta; Frusciante, Erika; Bassani, Niccolò; Panteghini, Mauro

    2016-10-01

    Serum human epididymis protein 4 (HE4) has gained relevance as an ovarian cancer (OC) biomarker and new automated methods have replaced the first released manual EIA by tracing results to it. We verified agreement and bias of automated methods vs. EIA as well as possible effects on patients' management. One hundred and fifteen serum samples were measured by Abbott Architect i2000, Fujirebio Lumipulse G1200, Roche Modular E170, and Fujirebio EIA. Passing-Bablok regression was used to compare automated assays to EIA and agreement between methods was estimated by Lin's concordance correlation coefficient (CCC). The bias vs. EIA was estimated and compared to specifications derived from HE4 biological variation. Median (25th-75th percentiles) HE4 concentrations (pmol/L) were 84.5 (60.1-148.8) for EIA, 82.7 (50.3-153.9) for Abbott, 89.1 (55.2-154.9) for Roche, and 112.2 (67.8-194.2) for Fujirebio. Estimated regressions and agreements (95% confidence interval) were: Abbott=1.01(0.98-1.03) EIA-4.8(-7.5/-2.6), CCC=0.99(0.99-1.00); Roche=0.91(0.89-0.93) EIA+5.7(4.2/8.0), CCC=0.98(0.98-0.99); Fujirebio=1.20(1.17-1.24) EIA+ 2.4(-0.6/4.9), CCC=0.97(0.96-0.98). The average bias vs. EIA resulted within the desirable goal for Abbott [-3.3% (-6.1/-0.5)] and Roche [-0.2% (-3.0/2.5)]. However, while for Abbott the bias was constant and acceptable along the measurement concentration range, Roche bias increased up to -28% for HE4 values >250 pmol/L. Lumipulse showed a markedly positive bias [25.3% (21.8/28.8)]. Abbott and Roche assays exhibited a good comparability in the range of HE4 values around the previously recommended 140 pmol/L cut-off. For patient monitoring, however, the assay used for determining serial HE4 must not be changed as results from different systems in lower and higher concentration ranges can markedly differ.

  9. Assessment of efficacy and tolerability of once-daily extended release metformin in patients with type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    S Yu Vorotnikova

    2012-09-01

    Full Text Available Реферат по статье: Assessment of efficacy and tolerability of once-daily extended release metformin in patients with type 2 diabetes mellitus Juliana Levy, Roberta A Cobas, Marilia B Gomes. Diabetol Metab Syndr. 2010 Mar 18; 2:16.

  10. B-Carotene-a long road to commercial implementation

    CSIR Research Space (South Africa)

    Gardiner, NS

    2006-09-01

    Full Text Available ) • Animal feed supplements • Food supplements – colorant, Vitamin A supplement • OTC pharmaceuticals (health supplements) – anti-oxidant, Vitamin A supplement © CSIR 2006 www.csir.co.zaSlide 4 Production • Chemical synthesis... • BASF, DSM (formerly Roche) • Algal production (Dunaliella salina) • Betatene (Cognis), Koor Foods, NCSA • Extraction from natural sources (carrots, palm oil) • DSM (formerly Roche), Hanson and Darius • Fungal production (Blakeslea trispora) • DSM...

  11. Real-time polymerase chain reaction detection of parvovirus B19 DNA in blood donations using a commercial and an in-house assay.

    Science.gov (United States)

    Koppelman, M H G M; van Swieten, P; Cuijpers, H T M

    2011-06-01

    European regulations require testing of manufacturing plasma for parvovirus B19 (B19) DNA to limit the load of this virus to a maximum acceptable level of 10 IU/µL. To meet this requirement, most manufacturers introduced a test algorithm to identify and eliminate high-load donations before making large manufacturing pools of plasma units. Sanquin screens all donations using a commercial assay from Roche and an in-house assay. Between 2006 and 2009, 6.2 million donations were screened using two different polymerase chain reaction (PCR) assays targeting B19 DNA. Donations with B19 DNA loads of greater than 1 × 10(6) IU/mL showing significant differences in viral load between the two assays were further analyzed by sequencing analysis. A total of 396 donations with B19 DNA loads of greater than 1 × 10(6) IU/mL were identified. Fifteen samples (3.8%) had discordant test results; 10 samples (2.5%) were underquantified by the Roche assay, two samples (0.5%) were underquantified by the in-house assay, and three samples (0.8%) were not detected by the Roche assay. Sequencing analysis revealed mismatches in primer and probe-binding regions. Phylogenetic analysis showed that 12 samples were B19 Genotype 1. The three samples not detected by the Roche assay were B19 Genotype 2. This study shows that 3.8% of the viremic B19 DNA-positive donations are not quantified correctly by the Roche or in-house B19 DNA assays. B19 Genotype 1 isolates showing incorrect test results are more common than B19 Genotype 2 or 3 isolates. Newly designed B19 PCR assays for blood screening should preferably have multiplexed formats targeting multiple regions of the B19 genome. © 2010 American Association of Blood Banks.

  12. Impact of Diagenetic Alterations on the Petrophysical and Multiphase Flow Properties of Carbonate Rocks Using a Reactive Pore Network Modeling Approach Impact des altérations diagénétiques sur les propriétés pétrophysiques et d’écoulement polyphasique de roches carbonates en utilisant une modélisation par l’approche réseau de pores

    Directory of Open Access Journals (Sweden)

    Algive L.

    2012-02-01

    replacing the original complex pore structure of real porous media by a conceptual network. The second step consists of resolving the governing equations of the precipitation and dissolution phenomena (i.e. reactive convection diffusion equation in the conceptual 3D pore network and deducing the local reactive fluxes and the motion of the fluid-solid interface. The third step consists of updating the new pore structure and calculating the new petrophysical properties of the modified porous media. Those steps are repeated in order to mimic a given diagenetic scenario. Finally, the multiphase flow properties of the current porous media are calculated. The impact of one diagenetic cycle of dissolution and precipitation on the pore networks’ heterogeneity and consequently on the petrophysical properties (i.e. porosity and permeability and multiphase flow properties (i.e. relative permeability and capillary pressure have been investigated. The permeability and porosity evolution during a given diagenetic cycle are calculated and analyzed as a function of the relevant dimensionless numbers (Peclet and Damköhler numbers that characterize the flow and reaction regime. The correlation between these numbers and the dissolved/precipitated layer thickness distribution is investigated. This work contributes to improve the understanding of the impact of dissolution and precipitation on permeability and porosity modification. Using the PNM approach, multiphase flow properties and permeability-porosity relationship have been determined for different reactive flow regimes. These relationships are relevant input data to improve the quality of reservoir simulation predictions. Les roches sédimentaires présentent souvent une structure porale hétérogène qui est intrinsèquement liée à la texture de la roche d’origine et aux modifications diagénétiques subies. Ces altérations sont régies par la texture de la roche d’origine, les fluides impliqués (et les interactions rock

  13. Pharmaceutical lobbying and pandemic stockpiling of Tamiflu: a qualitative study of arguments and tactics.

    Science.gov (United States)

    Vilhelmsson, Andreas; Mulinari, Shai

    2017-08-09

    Little is known about how pharmaceutical companies lobby authorities or experts regarding procurement or the use of vaccines and antivirals. This paper investigates how members of Denmark's pandemic planning committee experienced lobbying efforts by Roche, manufacturer of Tamiflu, the antiviral that was stockpiled before the 2009 A(H1N1) pandemic. Analysis of interviews with six of seven members of the Danish core pandemic committee, supplemented with documentary analysis. We sought to identify (1) arguments and (2) tactics used in lobbying, and to characterize interviewees' views on the impact of (3) lobbying and (4) scientific evidence on the decision to stockpile Tamiflu. Roche lobbied directly (in its own name) and through a seemingly independent third party. Roche used two arguments: (1) the procurement agreement had to be signed quickly because the drug would be delivered on a first-come, first-served basis and (2) Denmark was especially vulnerable to an influenza crisis because it had smaller Tamiflu stocks than other countries. Most interviewees suspected that lobbying had an impact on Tamiflu procurement. Our study highlights risks posed by pharmaceutical lobbying. Arguments and tactics deployed by Roche are likely to be repeated whenever many countries are negotiating drug procurements in a monopolistic market. © The Author 2017. Published by Oxford University Press on behalf of Faculty of Public Health.

  14. Peer Group Learning in Roche Pharma Development

    Science.gov (United States)

    Boulden, George P.; De Laat, Richard

    2005-01-01

    Pharma Development has used action learning to help participants in their 360[degrees] feedback programme develop their leadership competencies. The article describes how the programme was designed, supported and run across four sites over a period of 2 years. The programme was systematically evaluated and found to be successful in meeting its…

  15. Feasibility and accuracy evaluation of three human papillomavirus assays for FTA card-based sampling: a pilot study in cervical cancer screening

    International Nuclear Information System (INIS)

    Wang, Shao-Ming; Hu, Shang-Ying; Chen, Wen; Chen, Feng; Zhao, Fang-Hui; He, Wei; Ma, Xin-Ming; Zhang, Yu-Qing; Wang, Jian; Sivasubramaniam, Priya; Qiao, You-Lin

    2015-01-01

    Liquid-state specimen carriers are inadequate for sample transportation in large-scale screening projects in low-resource settings, which necessitates the exploration of novel non-hazardous solid-state alternatives. Studies investigating the feasibility and accuracy of a solid-state human papillomavirus (HPV) sampling medium in combination with different down-stream HPV DNA assays for cervical cancer screening are needed. We collected two cervical specimens from 396 women, aged 25–65 years, who were enrolled in a cervical cancer screening trial. One sample was stored using DCM preservative solution and the other was applied to a Whatman Indicating FTA Elute® card (FTA card). All specimens were processed using three HPV testing methods, including Hybrid capture 2 (HC2), careHPV™, and Cobas®4800 tests. All the women underwent a rigorous colposcopic evaluation that included using a microbiopsy protocol. Compared to the liquid-based carrier, the FTA card demonstrated comparable sensitivity for detecting high grade Cervical Intraepithelial Neoplasia (CIN) using HC2 (91.7 %), careHPV™ (83.3 %), and Cobas®4800 (91.7 %) tests. Moreover, the FTA card showed a higher specificity compared to a liquid-based carrier for HC2 (79.5 % vs. 71.6 %, P = 0.015), comparable specificity for careHPV™ (78.1 % vs. 73.0 %, P > 0.05), but lower specificity for the Cobas®4800 test (62.4 % vs. 69.9 %, P = 0.032). Generally, the FTA card-based sampling medium’s accuracy was comparable with that of liquid-based medium for the three HPV testing assays. FTA cards are a promising sample carrier for cervical cancer screening. With further optimization, it can be utilized for HPV testing in areas of varying economic development

  16. RANCANG BANGUN APLIKASI MONITORING DAN REKAM DATA SISTEM PENGENALAN SISTEM ISYARAT BAHASA INDONESIA BERBASIS SENSOR

    Directory of Open Access Journals (Sweden)

    Mohammad Iqbal

    2014-11-01

    Full Text Available ABSTRAK Dalam penelitian ini dikembangkan pengenalan sistem isyarat bahasa Indonesia (SIBI berbasis sensor yang diharapkan dapat memperbaiki akurasi, yaitu dengan menggunakan sensor flex untuk gerakan lekukan jari, dan menggunakan sensor accelerometer-gyroscope untuk mengetahui kemiringan/orientasi tangan. Untuk mendapatkan ekstraksi ciri dan metode pengenalan yang optimal, maka diperlukan uji coba dan analisis terhadap perbandingan ekstraksi ciri dan metode pengenalan, sehingga dapat ditentukan yang terbaik. Dalam uji coba dan analisis tersebut, maka diperlukan sampel data offline atau data yang sudah disimpan/direkam sebelumnya, sehingga diperlukan aplikasi untuk dapat merekam data (recording dan memonitoring data dari sensor-sensor yang dipasang pada sarung tangan. Dengan adanya data-data sensor tersebut, maka proses pemilihan ekstraksi ciri dan metode pengenalan yang optimal dapat dilakukan secara offline, menggunakan perangkat lunak komputasi. Capaian dapam Penelitian ini, adalah telah berhasil dikembangkan program aplikasi monitoring dan rekam data untuk sistem pengenalan SIBI. Data sensor yang dimonitoring dan direkam adalah data raw, sehingga perlu dilakukan pengolahan data untuk proses ekstraksi ciri sebelum diujicobakan pada metode pengenalan tertentu Kata kunci: SIBI, bahasa isyarat, sensor, flex, acclerometer, gyroscope, monitoring, recording.

  17. Pengembangan bahan Pembelajaran Berbantuan komputer (PBK untuk Memfasilitasi Active Learning dalam Mata Kuliah Landasan Kependidikan

    Directory of Open Access Journals (Sweden)

    Surtikanti Surtikanti

    2005-12-01

    Full Text Available Penelitian ini bertujuan untuk: (1 mengembangkan software PBK mata kuliah Landasan Kependidikan sebagai salah satu sumber media alternatif dalam rangka mencapai efektivitas, efisiensi dan daya tank untuk belajar; (2 menerapkan prinsip-prinsip desain pembelajaran (in­structional design dalam software pembelajaran Landasan Kependidikan; (3 Menentukan kelayakan produk pembelajaran landasan kependidikan berbantuan komputer agar dapat memfasilitasi active learning. Subjek penelitian terdiri dari 2 orang, (1 orang ahli mated dan 1 orang ahli media, 6 orang mahasiswa untuk uji coba kelompok kecil, dan 20 orang mahasiswa untuk uji coba lapangan. Data yang dijaring sesuai dengan jenisnya. Data kuantitatif dianalisis dengan statistik deskriptif sedangkan data kualitatif dengan naratif deskriptif. Hasil penelitian menunjukkan, bahwa: (1 Bahan PBK yang dirancang efektif digunakan untuk mencapai tujuan pembelajaran; (2 Bahan PBK memiliki efisiensi waktu yang tinggi dalam penyampaian isi pembelajaran; (3 Bahan PBK yang digunakan memiliki daya tarik yang tinggi; (4 isi program PBK sesuai dengan prinsip-prinsip desain pembelajaran; dan (5 program PBK ini dapat memfasilitasi strategi active learning. Kata kunci: pembelajaran berbantuan komputer, strategi active learning.

  18. PENGOLAHAN LIMBAH CAIR INDUSTRI FARMASI FORMULASI DENGAN METODE ANAEROB-AEROB DAN ANAEROB-KOAGULASI

    Directory of Open Access Journals (Sweden)

    Farida Crisnaningtyas

    2016-05-01

    Full Text Available Studi ini membahas mengenai pengolahan limbah cair industri farmasi dalam skala laboratorium dengan menggunakan konsep anaerob-kimia-fisika dan anaerob-aerob. Proses anaerob dilakukan dengan menggunakan reaktor Upflow Anaerobic Sludge Bed reactor (UASBr pada kisaran OLR (Organic Loading Rate 0,5 – 2 kg COD/m3hari, yang didahului dengan proses aklimatisasi menggunakan substrat gula. Proses anaerob mampu memberikan efisiensi penurunan COD hingga 74%. Keluaran dari proses anaerob diolah lebih lanjut dengan menggunakan dua opsi proses: (1 fisika-kimia, dan (2 aerob. Koagulan alumunium sulfat dan flokulan kationik memberikan efisiensi penurunan COD tertinggi (73% pada kecepatan putaran masing-masing 100 rpm dan 40 rpm. Uji coba aerob dilakukan pada kisaran MLSS antara 4000-5000 mg/L dan mampu memberikan efisiensi penurunan COD hingga 97%. Hasil uji coba menunjukkan bahwa efisiensi penurunan COD total yang dapat dicapai dengan menggunakan teknologi anaerob-aerob adalah 97%, sedangkan kombinasi anaerob-koagulasi-flokulasi hanya mampu menurunkan COD total sebesar 72,53%. Berdasarkan hasil tersebut, kombinasi proses anaerob-aerob merupakan teknologi yang potensial untuk diaplikasikan dalam sistem pengolahan limbah cair industri farmasi. 

  19. PENGEMBANGAN BAHAN AJAR DENGAN MODEL MIND MAP UNTUK PEMBELAJARAN ILMU PENGETAHUAN SOSIAL SMP

    Directory of Open Access Journals (Sweden)

    Lukman Lukman

    2014-12-01

    Full Text Available Penelitian ini bertujuan untuk menghasilkan bahan ajar dengan model mind map yang layak digunakan pada pembelajaran Ilmu Pengetahuan Sosial (IPS untuk siswa SMP, serta mengetahui keefektifan bahan ajar hasil pengembangan. Penelitian ini merupakan penelitian dan pengembangan (Research and Development. Hasil penelitian adalah sebagi berikut: (1 menghasilkan bahan ajar dengan model mind map untuk pembelajaran Ilmu Pengetahuan Sosial siswa SMP yang dikemas dalam bentuk buku dengan materi “Perkembangan pada Masa Islam di Indonesia”. Produk yang dihasilkan layak digunakan untuk pembelajaran berdasarkan validasi dari ahli materi, ahli media, uji coba terbatas, serta uji coba lapangan. (2 Bahan ajar hasil pengembangan untuk siswa kelas VII di SMP N 3 Berbah ini efektif digunakan untuk pembelajaran IPS. Peningkatan skor postes pada kelas yang menggunakan bahan ajar dengan model mind map sebesar 13,87% dengan nilai gain score 0,45 dan ketuntasan siswa 100%. Sedangkan kelas yang menggunakan buku paket IPS dengan peningkatan skor postes sebesar 10,26% dengan nilai gain score 0,35 dan ketuntasan siswa 87,1%. Kata kunci: bahan ajar, mind map, ilmu pengetahuan sosial

  20. Comparative evaluation of Amplicor HIV-1 DNA test, version 1.5, by ...

    African Journals Online (AJOL)

    Human immunodeficiency virus (HIV) DNA polymerase chain reaction (PCR) test using venous blood sample has been used for many years in low resource settings for early infant diagnosis of HIV infection in children less than 18 months. The aim of this study was to evaluate and compare the performance characteristics of ...

  1. Hepatitis B virus: molecular genotypes and HBeAg serological status among HBV-infected patients in the southeast of Brazil

    Directory of Open Access Journals (Sweden)

    Gonçales Fernando L

    2009-09-01

    Full Text Available Abstract Background Knowledge of HBV genotype is very important for clinical treatment. Studies have suggested possible pathogenic and therapeutic differences among HBV genotypes. The aim of this study was to determine HBV subtypes and genotypes in HBV-infected patients in our region (southeast Brazil and to correlate results with clinical and histopathological data. Methods One hundred and thirty-nine HBsAg-positive patients were included in the study. All patients were anti-HCV and anti-HIV negative (64% male; mean age 42 ± 14.5 years; range 7-80 years; 84% Caucasian and were followed up at the University Hospital. A method for genotyping and subtyping HBV by partial HBsAg gene sequencing with primers common to all known genotypes was used. The viral load was measured by Amplicor Monitor assay (Roche. Results HBV genotype A was the most prevalent (55%, while genotypes C, D and F were found in 3%, 38% and 4% of HBV-infected patients, respectively. Among the patients infected by genotype A, 18.3% (14/76 were African descendents and, among the patients infected by genotype D, 11.3% (6/53 were also African descendents. In the four patients infected with genotype C, 2 were Asian descendents and 2 were Caucasians. All (7 genotype F infected patients were Caucasians. Seventy percent of our HBsAg-positive patients were HBeAg negative (62% genotypes A; 26.2% D; 7.1% C and 4.7%F. The viral load of HBV-DNA was about 5 times higher in HBeAg-positive than in HBeAg-negative patients. About 40% of these patients had alanine aminotransferase of up to 1.5 times the normal level. The mean stage of fibrosis in genotype A patients (2.8 was significantly higher than the mean stage of fibrosis in genotype D patients (2.0 (P = 0.0179. Conclusion The genotypes encountered in our HBV-infected patients were apparently a consequence of the types of immigration that occurred in our region, where European and African descendents predominate. The HBeAg-negative status

  2. Kepatuhan Nahkoda Melakukan Pemeriksaan Boat Berdasarkan Check- List Harian untuk Keselamatan Pelayaran di Perusahaan Pelayaran

    OpenAIRE

    B, Rinto; Shaluhiyah, Zahroh; Kurniawan, Bina

    2012-01-01

    Terdapat penyimpangan prosedur dalam pemeriksaan boat berdasarkan checklist inspeksiyang sudah ada dimana rata-rata nahkoda melakukan pencontrengan checklist tanpamelakukan uji coba alat-alat keselamatan dan mesin di dalam boat. Tujuan penelitian iniadalah untuk mengeksplorasi gambaran tentang perilaku kepatuhan nahkoda di Perusahaanpelayaran ini dalam melakukan pemeriksaan boat berdasarkan checklist. Penelitian inimenggunakan metode penelitian kualitatif dengan melakukan wawancara yang menda...

  3. Géochimie isotopique (Nd, Sr) et géochilnie des éléments traces des basaltes alcalins du Massif Central français : Contraintes pétrogénétiques et arguments en faveur du métasomatisme mantellique.

    OpenAIRE

    Chauvel , Catherine

    1982-01-01

    no abstract; Les roches basiques ( basaltes, kimberlites, komatiites, etc ) proviennent par fusion partielle du manteau terrestre. L'étude géochimique de ces roches peut donc nous aider à comprendre la composition chimique et la structure de leurs sources mantelliques. Malgré les variations de composition chimique, les basaltes terrestres modernes peuvent être grossièrement classés en deux familles. La première, la famille des tholéiites, regroupe les basaltes de rides et de planchers océaniq...

  4. PENGEMBANGAN MULTIMEDIAPEMBELAJARAN BAHASA JERMAN PELAJARAN PELAYANAN RESTORAN DI YOTABAKTI YOGYAKARTA

    Directory of Open Access Journals (Sweden)

    Melly Handayani

    2015-10-01

    Full Text Available Tujuan penelitian dan pengembangan ini adalah (1 mengembangkan multimedia yang berisi materi dan latihan untuk keterampilan berbicara bahasa Jerman, (2 mendeskripsikan proses pengem-bangannya, dan (3 mendeskripsikan hasil evaluasi dan hasil uji coba lapangan. Uji coba terbatas dilakukan pada satu orang pengajar dan empat orang peserta didik. Uji coba lapangan melibatkan 2 orang pengajar dan 10 orang peserta didik. Data dianalisis secara deskriptif kuantitatif. Langkah pengembangan multimedia pembelajaran bahasa Jerman yang digunakan adalah (1 analisis kebutuhan, (2 perencanaan, (3 pengembangan produk, (4 evaluasi produk, (5 revisi produk, (6 uji coba lapangan, dan (7 produk akhir. Kualitas multimedia pembelajaran bahasa Jerman menurut dosen ahli materi adalah sangat baik dan menurut ahli media adalah baik. Kualitas multimedia menurut dua orang pengajar bahasa Jerman adalah sangat baik dan menurut peserta didik adalah baik. Dari 10 orang peserta didik, 80% mencapai nilai KKM. 100% respon peserta didik terhadap multimedia yang dikembangkan adalah sangat baik. Kata Kunci: Pengembangan, multimedia, keterampilan berbicara, pelayanan restoran   DEVELOPING MULTIMEDIA FOR GERMAN LANGUAGE TEACHING MATERIAL FOR RESTAURANT SERVICE LESSONS IN YOTABAKTI YOGYAKARTA Abstract The objectives of this research and development are (1 to develop a learning media for German language teachers, a computer assisted media with learning materials and exercises for speaking skill, (2 to describe the process of developing Multimedia German Language Teaching Material for Restaurant Service Lessons, and ( 3 to describe the result of product evaluation and field try out. The small group tryout involved five participants, a German language teacher and four students of Yotabakti. Field try out involved two German language teachers and ten students. The data of this study were analysed descriptively and quantitatively. The procedures of developing multimedia German language

  5. Early-type semidetached system LY Aurigae

    International Nuclear Information System (INIS)

    Li, Y.F.; Leung, K.C.

    1985-01-01

    In an effort to resolve a controversy regarding the configuration, mass ratio, and evolutionary status of the early-type close binary system LY Aur, the six bandpass OAO 2 observations of Heap and the ground-based observations combined by Eaton were analyzed. The Wilson and Devinney approach was used. The system is found to be semidetached, with the cooler and less massive component filling its Roche lobe, while the hotter component is close to its Roche surface. The system is not an early-type zero-age contact, as was suspected earlier. 20 references

  6. Smallpox and pan-orthopox virus detection by real-time 3'-minor groove binder TaqMan assays on the roche LightCycler and the Cepheid smart Cycler platforms.

    Science.gov (United States)

    Kulesh, David A; Baker, Robert O; Loveless, Bonnie M; Norwood, David; Zwiers, Susan H; Mucker, Eric; Hartmann, Chris; Herrera, Rafael; Miller, David; Christensen, Deanna; Wasieloski, Leonard P; Huggins, John; Jahrling, Peter B

    2004-02-01

    We designed, optimized, and extensively tested several sensitive and specific real-time PCR assays for rapid detection of both smallpox and pan-orthopox virus DNAs. The assays are based on TaqMan 3'-minor groove binder chemistry and were performed on both the rapid-cycling Roche LightCycler and the Cepheid Smart Cycler platforms. The hemagglutinin (HA) J7R, B9R, and B10R genes were used as targets for the variola virus-specific assays, and the HA and DNA polymerase-E9L genes were used as targets for the pan-orthopox virus assays. The five orthopox virus assays were tested against a panel of orthopox virus DNAs (both genomic and cloned) at the U.S. Army Medical Research Institute of Infectious Diseases (USAMRIID). The results indicated that each assay was capable of detecting both the appropriate cloned gene and genomic DNA. The assays showed no cross-reactivity to the 78 DNAs in the USAMRIID bacterial cross-reactivity panel. The limit of detection (LOD) of each assay was determined to be between 12 and 25 copies of target DNA. The assays were also run against a blind panel of DNAs at the Centers for Disease Control and Prevention (CDC) on both the LightCycler and the Smart Cycler. The panel consisted of eight different variola virus isolates, five non-variola virus orthopox virus isolates, two varicella-zoster virus isolates, and one herpes simplex virus isolate. Each sample was tested in triplicate at 2.5 ng, 25 pg, 250 fg, and 2.5 fg, which represent 1.24 x 10(7), 1.24 x 10(5), 1.24 x 10(3), and 1.24 x 10(1) genome equivalents, respectively. The results indicated that each of the five assays was 100% specific (no false positives) when tested against both the USAMRIID panels and the CDC blind panel. With the CDC blind panel, the LightCycler was capable of detecting 96.2% of the orthopox virus DNAs and 93.8% of the variola virus DNAs. The Smart Cycler was capable of detecting 92.3% of the orthopox virus DNAs and between 75 and 93.8% of the variola virus DNAs

  7. PENGEMBANGAN INSTRUMEN PENILAIAN KETERAMPILAN TEKNIK FOREHAND DAN BACKHAND DRIVE TENIS MEJA PADA ATLET USIA DINI

    Directory of Open Access Journals (Sweden)

    Verandita Rihtiana

    2014-09-01

    Full Text Available Penelitian ini bertujuan untuk mengembangkan instrumen penilaian keterampilan teknik forehand dan backhand drive tenis meja pada atlet usia dini. Penelitian ini menggunakan metode pene-litian dan pengembangan, dengan langkah-langkah pengembangan sebagai berikut: (1 pengumpulan informasi di lapangan, (2 melakukan analisis terhadap informasi yang dikumpulkan, (3 mengembangkan produk awal (draf model, (4 validasi ahli dan revisi, (5 uji coba skala kecil dan revisi, (6 uji coba skala besar dan revisi, (7 pembuatan produk final. Subjek penelitian atlet tenis meja usia dini. Analisis data untuk uji validitas dilakukan dengan CVR (content validity ratio dan reliabilitas dengan  menggunakan Alpha Crobanch. Penelitian ini menghasilkan buku panduan instrumen penilain keterampilan teknik forehand dan backhand drive tenis meja untuk atlet pemula  yang didalamnya berisi  petunjuk penggunaan, lembar tugas siswa, pedoman penilaian, rubrik penilaian, serta tabel penyekoran, yang memiliki validitas yang tinggi (1 dan reliabilitas yang tinggi¸forehand drive sikap awal: r = 0,975, pelaksanaan: r = 0,961, gerak lanjutan: r = 0, 955. Backhand drive sikap awal: r = 0,961, pelaksanaan r = 0,974, gerak lanjutan: r = 0, 989. Kata Kunci: instrumen penilaian teknik forehand dan backhand drive, tenis meja

  8. RANCANG BANGUN PROGRAM PENGEDITAN KURVA B-SPLINE MULTIRESOLUSI BERBASIS WAVELETS

    Directory of Open Access Journals (Sweden)

    Nanik Suciati

    2002-07-01

    Full Text Available Penelitian ini menyusun representasi multiresolusi untuk kurva B-spline kubik yang menginterpolasi titik-titik ujung dengan basis wavelets. Representasi multiresolusi ini digunakan untuk mendukung beberapa tipe pengeditan kurva, yaitu penghalusan kurva dengan tingkat resolusi kontinyu untuk menghilangkan detail-detail kurva yang tidak diinginkan, pengeditan bentuk keseluruhan kurva dengan tetap mempertahankan detaildetailnya, perubahan detail-detail kurva tanpa mempengaruhi bentuk keseluruhannya, dan pengeditan satubagian tertentu dari kurva melalui manipulasi secara langsung terhadap titik-titik kontrolnya. Untuk menguji kemampuan representasi multiresolusi dalam mendukung empat tipe manipulasi kurva tersebut, disusun program pengeditan kurva dengan menggunakan bahasa pemrograman Visual C++ pada komputer Pentium 133 MHz, memori 16 Mbyte, sistem operasi Windows 95, lingkungan pengembangan Microsoft DevelopmentStudio 97 dan pustaka Microsoft Foundation Class. Dari hasil uji coba program diketahui bahwa representasi multiresolusi memberikan dukungan yang sangat baik terhadap tipe-tipe pengeditan seperti yang disebutkan di atas. Representasi multiresolusi tidak membutuhkan memori penyimpan ekstra selain dari yang digunakan untuk menyimpan titik kontrol. Dari hasil uji coba program menggunakan ratusan titik kontrol, algoritma berjalan cukup cepat dan memadai berkaitan dengan tuntutan komunikasi interaktif antara user dan program.Kata kunci: B-Spline, Wavelet, Multiresolusi

  9. Is there a suitable point-of-care glucose meter for tight glycemic control? Evaluation of one home-use and four hospital-use meters in an intensive care unit.

    Science.gov (United States)

    Gijzen, Karlijn; Moolenaar, David L J; Weusten, Jos J A M; Pluim, Hendrik J; Demir, Ayse Y

    2012-11-01

    Implementation of tight glycemic control (TGC) and avoidance of hypoglycemia in intensive care unit (ICU) patients require frequent analysis of blood glucose. This can be achieved by accurate point-of-care (POC) hospital-use glucose meters. In this study one home-use and four different hospital-use POC glucose meters were evaluated in critically ill ICU patients. All patients (n = 80) requiring TGC were included in this study. For each patient three to six glucose measurements (n = 390) were performed. Blood glucose was determined by four hospital-use POC glucose meters, Roche Accu-Check Inform II System, HemoCue Glu201DM, Nova StatStrip, Abbott Precision Xceed Pro, and one home-use POC glucose meter, Menarini GlucoCard Memory PC. The criteria described in ISO 15197, Dutch TNO quality guideline and in NACB/ADA-2011 were applied in the comparisons. According to the ISO 15197, the percentages of the measured values that fulfilled the criterion were 99.5% by Roche, 95.1% by HemoCue, 91.0% by Nova, 96.6% by Abbott, and 63.3% by Menarini. According to the TNO quality guideline these percentages were 96.1% , 91.0% , 81.8% , 94.2% , and 47.7% , respectively. Application of the NACB/ADA guideline resulted in percentages of 95.6%, 89.2%, 77.9%, 93.4%, and 45.4%, respectively. When ISO 15197 was applied, Roche, HemoCue and Abbott fulfilled the criterion in this patient population, whereas Nova and Menarini did not. However, when TNO quality guideline and NACB/ADA 2011 guideline were applied only Roche fulfilled the criteria.

  10. Karst et ressources en eau au moyen Atlas nord-oriental

    OpenAIRE

    Taous, Ali; Tribak, Abdellatif; Obda, Khalid; Baena Escudero, Rafael; López Lara, Enrique Javier; Miranda Bonilla, Jose

    2009-01-01

    Le Moyen Atlas nord-oriental se caractérise par des paysages kartisques hérités et actuels très diversifiés. En fait, les roches carbonatées du Jurassique, bien représentées dans cette région montagneuse, ont subi une karstification ancienne, depuis la fin du Tertiaire et au cours du Quaternaire. Actuallement, la karstogenèse est encore active en raison des conditions géologiques, morphostructurales et bioclimatiques favorables: couches de roches carbonatées inclinées et plissées, climat médi...

  11. Smallpox and pan-Orthopox Virus Detection by Real-Time 3′-Minor Groove Binder TaqMan Assays on the Roche LightCycler and the Cepheid Smart Cycler Platforms

    Science.gov (United States)

    Kulesh, David A.; Baker, Robert O.; Loveless, Bonnie M.; Norwood, David; Zwiers, Susan H.; Mucker, Eric; Hartmann, Chris; Herrera, Rafael; Miller, David; Christensen, Deanna; Wasieloski, Leonard P.; Huggins, John; Jahrling, Peter B.

    2004-01-01

    We designed, optimized, and extensively tested several sensitive and specific real-time PCR assays for rapid detection of both smallpox and pan-orthopox virus DNAs. The assays are based on TaqMan 3′-minor groove binder chemistry and were performed on both the rapid-cycling Roche LightCycler and the Cepheid Smart Cycler platforms. The hemagglutinin (HA) J7R, B9R, and B10R genes were used as targets for the variola virus-specific assays, and the HA and DNA polymerase-E9L genes were used as targets for the pan-orthopox virus assays. The five orthopox virus assays were tested against a panel of orthopox virus DNAs (both genomic and cloned) at the U.S. Army Medical Research Institute of Infectious Diseases (USAMRIID). The results indicated that each assay was capable of detecting both the appropriate cloned gene and genomic DNA. The assays showed no cross-reactivity to the 78 DNAs in the USAMRIID bacterial cross-reactivity panel. The limit of detection (LOD) of each assay was determined to be between 12 and 25 copies of target DNA. The assays were also run against a blind panel of DNAs at the Centers for Disease Control and Prevention (CDC) on both the LightCycler and the Smart Cycler. The panel consisted of eight different variola virus isolates, five non-variola virus orthopox virus isolates, two varicella-zoster virus isolates, and one herpes simplex virus isolate. Each sample was tested in triplicate at 2.5 ng, 25 pg, 250 fg, and 2.5 fg, which represent 1.24 × 107, 1.24 × 105, 1.24 × 103, and 1.24 × 101 genome equivalents, respectively. The results indicated that each of the five assays was 100% specific (no false positives) when tested against both the USAMRIID panels and the CDC blind panel. With the CDC blind panel, the LightCycler was capable of detecting 96.2% of the orthopox virus DNAs and 93.8% of the variola virus DNAs. The Smart Cycler was capable of detecting 92.3% of the orthopox virus DNAs and between 75 and 93.8% of the variola virus DNAs. However

  12. Hubungan Antara Persepsi Terhadap Beban Kerja Dengan Cyberloafing Pada Karyawan Biro Administrasi Umum Dan Keuangan Universitas Diponegoro

    OpenAIRE

    Ramadhan, Hafidz Ibnu; Nurtjahjanti, Harlina

    2017-01-01

    Penelitian ini bertujuan untuk mengetahui hubungan antara persepsi terhadap beban kerja dengan cyberloafing pada karyawan biro administrasi umum dan keuangan Universitas Diponegoro. Cyberloafing merupakan perilaku menggunakan berbagai jenis gadget, baik milik instansi ataupun milik pribadi dengan tujuan yang tidak berkaitan dengan pekerjaan yang dilakukan secara sadar oleh karyawan ditempat dan saat jam kerja. Penelitian ini memiliki sampel sebanyak 45 karyawan untuk uji coba skala dan 60 kar...

  13. PENGEMBANGAN MODEL PELATIHAN SOFT-SKILLS PADA SISWA SEKOLAH MENENGAH PERTAMA NEGERI (SMPN) DI KOTA MATARAM

    OpenAIRE

    Anik Darmiany

    2016-01-01

    Abstrak : Penelitian dan pengembangan ini bertujuan menghasilkan model pelatihan soft-skill khususnya keterampilan komunikasi dan kendali emosi siswa sekolah menengah pertama negeri (SMPN) di kota Mataram. Metode penelitian dan pengembangan dilakukan melalui tiga tahap dari sepuluh langkah Borg & Gall yaitu, (1) penelitian awal (analisis kebutuhan), (2) pengembangan model pelatihan, (3) uji coba dan evaluasi model. Hasil penelitian menunjukkan bahwa pengembangan model pelatihan soft-skill men...

  14. PENGEMBANGAN WEB INTRANET FISIKA UNTUK MENINGKATKAN PENGUASAAN KONSEP DAN KEMAMPUAN PEMECAHAN MASALAH SISWA SMK

    Directory of Open Access Journals (Sweden)

    A. Doyan

    2014-07-01

    Full Text Available Penelitian ini bertujuan untuk mengembangkan media pembelajaran web intranet fisika dan mengetahui pengaruhnya terhadap penguasaan konsep dan kemampuan pemecahan masalah siswa. Penelitian ini menggunakan desain penelitian dan pengembangan model Borg dan Gall yang dimodifikasi menjadi tiga tahap, yaitu tahap studi pendahuluan, tahap pengembangan media,dan tahap uji coba media. Tahap studi pendahuluan dilaksanakan dengan studi kepustakaan dan survei awal. Tahap pengembangan media menghasilkan draf awal media. Penelitian dilanjutkan dengan tahap implementasi uji coba terbatas dan uji coba lebih luas media pembelajaran web intranet fisika di SMKN 2 Praya Tengah. Pembelajaran materi usaha, energi, dan daya di kelas eksperimen menggunakan web intranet fisika sedangkan di kelas kontrol menggunakan pembelajaran konvensional. Kedua kelas dianalisis menggunakan uji perbedaan rata-rata (Uji t atau Uji Mann-Whitney dan skor gain ternormalisasi (N-gain. Berdasarkan hasil penelitian dapat disimpulkan bahwa pembelajaran web intranet fisika efektif meningkatkan penguasaan konsep tetapi tidak efektif meningkatkan kemampuan pemecahan masalah siswa SMK.ABSTRACTThe research was aimed at developing a learning media of physics intranet web and knowing its impacts to the student’s concept comprehension and problem solving skills. The research used a research design and development model of Borg and Gall which was modified into three stages; those were stage of preliminary study, stage of media development, and stage of media testing.The stage of preliminary study was conducted by having literature review and initial survey. Furthermore media development generated an initial draft of media. The research was continued with the stage of limited testing and more extensive testing implementation of physics intranet web learning media at SMKN 2 Praya Tengah. The learning material of work, energy and power in the experimental group used the physics intranet web, while the

  15. On the Roche constants for main-sequence binaries

    International Nuclear Information System (INIS)

    Giannuzzi, M.A.

    1979-01-01

    The ratios C 1 /C 2 of the constants defining the equipotential surfaces which describe the external forms of the components of a close binary system have been calculated on the basis of evolutionary models. Theoretical systems have been considered allowing for a wide range of input parameters (masses and separation) and taking into account the evolutionary effects on the radii of the stars during their Main-Sequence lifetime. The systems have not undergone any transfer of matter and are representative of detached binaries with Main-sequence components. The ratios of the constants are confined in limited intervals and, for the highest values of the mass-ratios, they are clustered around the unit. (Auth.)

  16. Nutritionally fastidious Ruminococc$t f lovefociens: strains | Roche ...

    African Journals Online (AJOL)

    The majority of Ruminococcus flavefaciens strains isolated in our laboratories failed to grow or grew poorly both in rumen' fluid medium and in a chemically defined medium containing all the nutrients reported to be required for good growth of this species. ttemptsw ere made to developa defined medium wnicnw ould ...

  17. PENGEMBANGAN PERANGKAT PEMBELAJARAN MATEMATIKA YANG MENUNJANG PENDIDIKAN KARAKTER SISWA KELAS IV SEKOLAH DASAR

    Directory of Open Access Journals (Sweden)

    Layin Fauziyah

    2014-07-01

    Full Text Available Penelitian ini bertujuan untuk menghasilkan perangkat pembelajaran matematika yang menun-jang pendidikan karakter siswa kelas V sekolah dasar yang layak. Penelitian ini adalah penelitian pengembangan dengan menggunakan model pengembangan 4-D yang dikembangkan oleh Thiagarajan, Semmel & Semmel yang telah dimodifikasi sehingga memuat tahapan define, design, dan develop. Produk yang dikembangkan adalah perangkat pembelajaran yang terdiri dari RPP, LKS, bahan ajar/buku siswa dan tes hasil belajar. Pengembangan perangkat pembelajaran dimulai dari tahap analisis awal-akhir, analisis peserta didik, analisis materi, analisis tugas, spesifikasi tujuan pembel-ajaran, pemilihan media, pemilihan format, validasi ahli, uji coba terbatas, uji coba lapangan, dan revisi. Instrumen penelitian yang digunakan terdiri dari lembar validasi, lembar observasi karakter siswa, dan lembar observasi kemampuan guru dalam mengelola pembelajaran untuk mengetahui keterlaksanaan RPP yang menunjang pendidikan karakter. Penelitian ini menghasilkan perangkat pembelajaran yang menunjang pendidikan karakter pada materi pecahan. Hasil validasi perangkat pembelajaran yang dikembangkan layak untuk digunakan dengan kategori cukup valid, praktis, dan efektif. Pembelajaran dengan menggunakan perangkat yang dikembangkan dapat membentuk karakter jujur, disiplin, dan bertanggung jawab. Berdasarkan pengamatan yang telah dilakukan, perangkat pembelajaran matematika yang dikembangkan pada uji coba terbatas dan uji coba lapangan menunjukkan peningkatan karakter siswa di setiap pertemuan. _________________________________________________________________________________________________________________________________________________________________________________________________________ DEVELOPING MATHEMATIC TEACHING KITS THAT SUPPORT THE CHARACTER EDUCATION OF THE STUDENTS IN CLASS V OF ELEMENTARY SCHOOLS ABSTRACT This research aims to develop appropriate mathematic teaching kits that support

  18. Primary Screening for Cervical Cancer Based on High-Risk Human Papillomavirus (HPV) Detection and HPV 16 and HPV 18 Genotyping, in Comparison to Cytology

    Science.gov (United States)

    Constantinidis, Theocharis; Constantinidis, Theodoros C.

    2015-01-01

    Objectives The objective of the present study is to assess the performance of a high-risk human papillomavirus (HR-HPV) DNA test with individual HPV-16/HPV-18 genotyping as a method for primary cervical cancer screening compared with liquid-based cytology (LBC) in a population of Greek women taking part in routine cervical cancer screening. Methods The study, conducted by the “HEllenic Real life Multicentric cErvical Screening” (HERMES) study group, involved the recruitment of 4,009 women, aged 25–55, who took part in routine cervical screening at nine Gynecology Departments in Greece. At first visit cervical specimens were collected for LBC and HPV testing using the Roche Cobas 4800 system. Women found positive for either cytology or HPV were referred for colposcopy, whereas women negative for both tests will be retested after three years. The study is ongoing and the results of the first screening round are reported herein. Results Valid results for cytology and HPV testing were obtained for 3,993 women. The overall prevalence of HR-HPV was 12.7%, of HPV-16 2.7% and of HPV-18 1.4%. Of those referred for colposcopy, cervical intraepithelial neoplasia grade 2 or worse (CIN2+) was detected in 41 women (1.07%). At the threshold of CIN2+, cytology [atypical squamous cells of undetermined significance (ASC-US) or worse] and HPV testing showed a sensitivity of 53.7% and 100% respectively, without change between age groups. Cytology and HPV testing showed specificity of 96.8% and 90.3% respectively, which was increased in older women (≥30) in comparison to younger ones (25–29). Genotyping for HPV16/18 had similar accuracy to cytology for the detection of CIN2+ (sensitivity: 58.5%; specificity 97.5%) as well as for triage to colposcopy (sensitivity: 58.5% vs 53.7% for cytology). Conclusion HPV testing has much better sensitivity than cytology to identify high-grade cervical lesions with slightly lower specificity. HPV testing with individual HPV-16/HPV-18

  19. Impact of Endogenous and Exogenous Interferences on Clinical Chemistry Parameters Measured on Blood Gas Analyzers.

    Science.gov (United States)

    Grieme, Caleb V; Voss, Dena R; Davis, Scott R; Krasowski, Matthew D

    2017-03-01

    The prevalence of hemolysis, icterus, and lipemia (HIL) was determined for residual whole blood specimens analyzed for clinical chemistry parameters on blood gas analyzers. The frequency and potential impact of exogenous interference from iodide, salicylate, and thiocyanate (metabolite of sodium nitroprusside) on analysis of whole blood chloride was also assessed. Over an approximately two month period at an academic medical center, indices for HIL were determined on Roche cobas c502 analyzers for 1,986 residual whole blood specimens that had been previously analyzed for clinical chemistry parameters on Radiometer ABL90 FLEX blood gas analyzers. To examine exogenous interferences, retrospective analysis was performed over multiple years to ascertain whether patient samples analyzed for whole blood chloride were potentially affected by interference from iodide, salicylate, or thiocyanate. Some degree of hemolysis (defined as hemolysis index of greater than 60) was present in 9.7% of the whole blood specimens. Increasing rates of hemolysis were associated with higher whole blood potassium concentrations. Nearly 60% of specimens with potassium concentrations between 6.0 and 6.9 mEq/L had hemolysis indices of 100 or greater, and 75% of specimens with a potassium concentration of 7.0 mEq/L or greater were severely hemolyzed (hemolysis index of 300 or greater). In contrast to the hemolysis results, icterus and lipemia were determined to have minimal impact on patient results. For the exogenous interferences, we did not identify any patient samples where elevated salicylate levels or pharmaceutical iodide administration overlapped with whole blood chloride analysis (out of 75,887 and 169,229 total chloride measurements, respectively). We did, however, find that for patients receiving nitroprusside therapy in the inpatient setting, whole blood chloride concentrations were significantly higher during nitroprusside therapy [106.7 +/- 6.2 mEq/L (mean, SD)] compared to before

  20. Lack of Correlation of the Serum 25(OH Vitamin D Levels with the Glycated Hemoglobin A1c and the Lipid Profile in Type 2 Diabetes Patients on Oral Antidiabetic Drugs – Preliminary Data

    Directory of Open Access Journals (Sweden)

    Bakalov D.

    2014-12-01

    Full Text Available Data from different studies correlating the serum 25(OHD levels with the metabolic and glycemic parameters in type 2 diabetes patients are still varying. The objective if this study was to describe the correlation between serum 25(OHD levels and some metabolic parameters in Bulgarian type 2 diabetes patients on oral antidiabetic drugs. One hundred type 2 diabetes patients participated - 56 men and 44 women. The mean age and diabetes duration of the women was 59.0 and 9.8 years, of the men - 58.0 and 7.7 years respectively. Complete patient history was taken and physical examination was performed (body weight and height, waist circumference. Body composition was measured on a leg-to-leg body impedance analyzer (TBF-215, Tanita Corp., Tokyo, Japan. Serum levels of vitamin D were measured by electro-hemi-luminescent detection as 25-(ОН D Total (ECLIA, Elecsys 2010, Roche Diagnostics, Switzerland. Glycated hemoglobin A1c was measured on a NycoCard reader (Alere™. Total, HDL-cholesterol (direct and triglycerides were analyzed on a Cobas Integra 400+ analyzer. Correlation analysis was performed on a SPSS 13.0 for Windows platform and included 10 curves. The data were first analyzed for the group as a whole and then separately for men and women as well as in the different vitamin D tertiles. The mean serum 25-OH-vitamin D levels were 23.8 ± 12.1 nmol/l in women and 33.3 ± 20.0 nmol/l in men. We were unable to find any statistically significant correlation between serum 25(OH vitaminand the serum lipids (cholesterol profile and triglycerides. On the contrary, there was a weak correlation with the glycated hemoglobin A1c (cubic model, R2 = 0.178, p = 0.05 and the BMI (inverse model, R2 = 0.101, p = 0.038. The sub-analyses (men versus women or according to tertiles of vitamin D did not produce any additional information. The influence of vitamin D on the parameters of the metabolic control in type 2 diabetes is very weak on an individual level. It

  1. Evaluation of serum lipids and lipoproteins as prognosticators in leukoplakia.

    Science.gov (United States)

    Ganavi, B S; Patil, Shankargouda; Rao, Roopa S

    2014-05-01

    Oral cancer is the 8th most common cancer worldwide. Squamous cell carcinomas constitute 94% of all oral malignancies and are often preceded by leukoplakia. Despite many adjunctive techniques to monitor transformation of leukoplakia to oral squamous cell carcinoma (OSCC), the mortality rate is on the rise. Incidentally, patients diagnosed with oral potentially malignant disorders (OPMDs) and oral cancers manifest with low choles-terol levels. Given a thought, hypolipidemia may be a useful adjunctive tool as it reflects the initial changes within the neo-plastic cells, thus giving a red alert in malignant transformation of leukoplakia at the earlier stage. To evaluate the feasibility of serum lipid profile as an adjunct early marker for malignant transformation of leukoplakia to OSCC. To estimate the serum cholesterol, triglycerides and lipoprotein (HDL, LDL, VLDL) levels in patients with leukoplakia, OSCC and age matched healthy control group. To compare the serum cholesterol, triglycerides and lipoprotein levels between patients of leukoplakia, OSCC and age matched healthy control group. The study group comprised of selected 30 individuals which included 10 each of histopathologically confirmed OSCC, leukoplakia and healthy controls. A written consent was taken from all of them, and a thorough case history was recorded and then venous blood was collected 12 hours post fasting and centrifuged. The serum cholesterol, triglycerides and HDL were estimated by enzymatic and colorimetric methods using commercially available kits--Roche/ Hitachi cobas systems. Chemistry assay QC procured from Bio-Rad was used as control. VLDL and LDL were derived from these values. Results were statistically analyzed using ANOVA and post hoc Tukey Test. Oral squamous cell carcinoma patients demonstrated significantly lower mean serum cholesterol level (151.60 mg/dl) than the control group (183.70 mg/dl). The mean cholesterol level in leukoplakia patients (173.90 mg/dl) was lower than that

  2. Effects of Growth Hormone/IGF-I and Exercise on Unloaded Bones

    Science.gov (United States)

    Harper, J. S.; Arnaud, S. B.; Gosselink, K. L.; Grindeland, R. E.

    1994-01-01

    Growth hormone (GH) and insulin-like growth factor-I (IGF-I) in combination with exercise prevent muscle atrophy induced by unloading in the tail-suspension rat model for space flight (Gosselink et al, FASEB J 1994). This study evaluated the effects of these treatments on bone. Hypophysectomized rats were suspended (S) and treated with 1mg/kg/day CH plus IGF-I (H) or vehicle (Sal) daily by injection and exercised (Ex) by 3 climbs up a 1m ladder carrying a load equal to 30% the initial body weight (BW) 3x/day for 10 days. Tibial epiphysis (Epi) widths were measured by micrometry and femoral Bone Mineral Content (fBMC) in excised femurs by DEXA (Lunar DPX-L). Serum calcium (Ca) and phosphorus (Pi) were measured by COBAS Autoanalyzer (Roche Diag.). Ambulatory (Amb)-H treated rats showed growth rates of 6.6+-0.9 g/day, similar to S-H-Ex and higher than S-H (3.210.6, p less than 0.05) and S-Sal (-0.711.0, p less than 0.05). Epi widths were 10% lower in S-Sal, and S-Sal-Ex, and increased 100% in all H groups. fBMC was less in S than Amb, only when all S groups are compared to both Amb groups (p less than 0.03). H treatment increased fBMC (p less than 0.05) but reduced fBMC/100g BW in all H groups (p less than 0.001). The reduced density of H bone cannot be attributed to low circulating Ca. and Pi since they were higher in H than Sal (p less than 0.001). H treatment for 10 days in doses sufficient to support normal growth in BW failed to produce normal Epi widths or fBMC, even when combined with exercise. The suspension effect observed in Epi widths was not corrected by H or Ex alone, but was improved by H plus a This regimen. although effective in preventing muscle atrophy, failed to return bone measures, Epi widths and fBMC, to normal.

  3. VOLUME 1: ASIAN HIGHLANDS PERSPECTIVES

    Directory of Open Access Journals (Sweden)

    VARIOUS

    2009-06-01

    Full Text Available Amdo Tibetan Tongue Twisters Blo rtan rdo rje, Charles Kevin Stuart, and Gerald Roche……....7 An Amdo Tibetan Village New Year Trance Medium Ritual Dpal ldan bkra shis and Charles Kevin Stuart …..…...........…53 Calling Back the Lost na53 mʑi53 Tibetan Soul Libu Lakhi, Charles Kevin Stuart, and Gerald Roche ..…........65 Dying Hunters, Poison Plants, and Mute Slaves: Nature and Tradition in Contemporary Nuosu Yi Poetry Mark Bender........................................................................117 The Ĕrsū Shābā Pictographic Writing System Sūn Hóngkāi [translated by Mtsho mo skyid and Gerald Roche with an introduction by Thomas Roche and Gerald Roche] ………............……………………........……..…..159 The Fourth Belmang: Bodhisattva, Estate Lord, Tibetan Militia Leader, and Chinese Government Official Paul K Nietupski …………….….…….….…….…………187 The Horse With Two Saddles: Tamxhwe in Modern Golok Fernanda Pirie ….………........……………………..…………..213 Seating, Money, and Food at an Amdo Village Funeral Rin chen rdo rje and Charles Kevin Stuart ..….…....….…..….237 The Seng ze Village Ma Ni Dkon mchog dge legs and Charles Kevin Stuart ……..….….295 Tibetan Life and Tibetological Discourse: Differences and Recommendations Gerald Roche, Nag tshang grub rgyal, and Mtsho mo skyid…313 A Response to Ways and the Syntax of Noun Phrases in Qīnghăi Chinese Dialects Keith Dede .……..….….….…..……..…..….….…………331 Photo Essay Photo Essayto Essay to Essay Lazi (Lab rtse Construction in Karmatang (Skar ma thang Village Tshe mdo ………………..……..….…….………………..349 Review Wutun. By J Janhunen, M Peltomaa, E Sandman, and Xiawudongzhuo. Keith Slater ….….….……..………...….…..….….….…...367 Story God-door Tshe dpag rnam rgyal ………….….….….…..….….….….373

  4. Étude numérique du couplage thermohydromécanique dans les roches. Influence des termes de couplage non linéaires pour un matériau isotrope linéaire Numerical Analysis of a Thermohydromechanical Coupling in Rocks. Influence of Nonlinear Coupling Terms on a Linear Isotropic Material

    Directory of Open Access Journals (Sweden)

    Henry J. P.

    2006-11-01

    Full Text Available Nous présentons dans ce travail une étude numérique basée sur la méthode des éléments finis, du comportement thermoporoélastique de certaines roches. Les trois effets de couplage : déformabilité de la roche, pression interstitielle et température sont pris en compte simultanément dans la résolution numérique. Une application simple sur un puits pétrolier en conditions axisymétriques est finalement présentée afin de dégager en particulier l'influence du terme de couplage convectif non linéaire, obtenu dans l'équation de diffusivité thermique, sur l'évolution de la température et de la pression interstitielle autour du forage. This article describes a finite-element method for solving the problem of nonlinear coupling between interstitial pressure and temperature during stress on a poroelastic rock. Such coupling phenomena occur during massive injection of cold water into a petroleum borehole for example. The implementation of such a numerical solution, used here with the assumption of small deformations, first requires a review of the behavior law of the material (Eq. 2. 2 and of the equations for hydraulic diffusivity (Eq. 2. 3 and thermal diffusivity (Eq. 2. 4. This last equation (2. 4 is the one containing the nonlinear coupling terms in Grad P Grad P and Grad T. Grad P. During simulation of flow at a high flow rate, these products can no longer be neglected as shown by the results in Fig. 2. The variational formulation of the problem is then determined in relation to the three equations for equilibrium, thermal diffusivity and hydraulic diffusivity. After geometric and temporal discretizations, this formulation leads to a finite-element calculating scheme resulting in the simultaneous solving of all three equations. This solution, based on the inversion of the system of equations (2. 15, requires the updating of the rigidity matrix at each time step to take nonlinear coupling into consideration. Calculations with an

  5. SWIFT J1749.4-2807: A neutron or quark star?

    International Nuclear Information System (INIS)

    Yu Junwei; Xu Renxin

    2010-01-01

    We investigate a unique accreting millisecond pulsar with X-ray eclipses, SWIFT J1749.4-2807 (hereafter J1749), and try to set limits on the binary system by various methods including use of the Roche lobe, the mass-radius relations of both main sequence (MS) and white dwarf (WD) companion stars, as well as the measured mass function of the pulsar. The calculations are based on the assumption that the radius of the companion star has reached its Roche radius (or is at 90%), but the pulsar's mass has not been assumed to be a certain value. Our results are as follows. The companion star should be an MS one. For the case that the radius equals its Roche one, we have a companion star with mass M ≅ 0.51 M o-dot and radius R c ≅ 0.52 R o-dot , and the inclination angle is i ≅ 76.5 0 ; for the case that the radius reaches 90% of its Roche one, we have M ≅ 0.43 M o-dot , R c ≅ 0.44 R o-dot and i ≅ 75.7 0 . We also obtain the mass of J1749, M p ≅ 1 M o-dot , and conclude that the pulsar could be a quark star if the ratio of the critical frequency of rotation-mode instability to the Keplerian one is higher than ∼ 0.3. The relatively low pulsar mass (about ∼ M o-dot ) may also challenge the conventional recycling scenario for the origin and evolution of millisecond pulsars. The results presented in this paper are expected to be tested by future observations. (letters)

  6. Wind-driven angular momentum loss in binary systems. I - Ballistic case

    Science.gov (United States)

    Brookshaw, Leigh; Tavani, Marco

    1993-01-01

    We study numerically the average loss of specific angular momentum from binary systems due to mass outflow from one of the two stars for a variety of initial injection geometries and wind velocities. We present results of ballistic calculations in three dimensions for initial mass ratios q of the mass-losing star to primary star in the range q between 10 exp -5 and 10. We consider injection surfaces close to the Roche lobe equipotential surface of the mass-losing star, and also cases with the mass-losing star underfilling its Roche lobe. We obtain that the orbital period is expected to have a negative time derivative for wind-driven secular evolution of binaries with q greater than about 3 and with the mass-losing star near filling its Roche lobe. We also study the effect of the presence of an absorbing surface approximating an accretion disk on the average final value of the specific angular momentum loss. We find that the effect of an accretion disk is to increase the wind-driven angular momentum loss. Our results are relevant for evolutionary models of high-mass binaries and low-mass X-ray binaries.

  7. The future of discovery chemistry: quo vadis? Academic to industrial--the maturation of medicinal chemistry to chemical biology.

    Science.gov (United States)

    Hoffmann, Torsten; Bishop, Cheryl

    2010-04-01

    At Roche, we set out to think about the future role of medicinal chemistry in drug discovery in a project involving both Roche internal stakeholders and external experts in drug discovery chemistry. To derive a coherent strategy, selected scientists were asked to take extreme positions and to derive two orthogonal strategic options: chemistry as the traditional mainstream science and chemistry as the central entrepreneurial science. We believe today's role of medicinal chemistry in industry has remained too narrow. To provide the innovation that industry requires, medicinal chemistry must play its part and diversify at pace with our increasing understanding of chemical biology and network pharmacology. 2010 Elsevier Ltd. All rights reserved.

  8. Geochemical, petrological and geochronological observations on the metamorphic rocks of the Tauride belt ophiolites (S. Turkey)

    OpenAIRE

    Celik, Omer Faruk

    2002-01-01

    La chaîne du Taurus (sud de la Turquie) comprend une succession de massifs ophiolitiques. Chacun d'eux possède une semelle métamorphique. Les principales roches constituant ces semelles sont des amphibolites qui se caractérisent, grâce à la géochimie des éléments en traces et des Terres Rares, en basaltes d'îles océaniques, en tholéites d'arcs ou en basaltes de rides. Ces roches sont regroupées par des filons doléritiques et gabbroïques tardifs. L'étude géothermobarométrique montre que ces am...

  9. PENGEMBANGAN MULTIMEDIA PEMBELAJARAN INTERAKTIF KOMPETENSI DASAR PEMASANGAN SISTEM PENERANGAN DAN WIRING KELISTRIKAN DI SMK

    Directory of Open Access Journals (Sweden)

    Nopriyanti Nopriyanti

    2015-06-01

    Full Text Available Penelitian ini bertujuan untuk: (1 menghasilkan multimedia pembelajaran interaktif kompetensi dasar pemasangan sistem penerangan dan wiring kelistrikan; (2 mengetahui kualitas multimedia pembelajaran interaktif; dan (3 mengetahui efektifitas multimedia pembelajaran interaktif kompetensi dasar pemasangan sistem penerangan dan wiring kelistrikan pada kelas XI SMK bidang keahlian Teknik Kendaraan Ringan. Penelitian ini merupakan penelitian dan pengembangan. Validasi multimedia dilakukan oleh ahli materi dan ahli media. Subjek uji coba penelitian ini adalah 32 siswa kelas XI SMKN 2 Depok, Sleman, Yogyakarta bidang keahlian Teknik Kendaraan Ringan. Kesimpulan dari penelitian ini adalah: (1 produk multimedia pembelajaran interaktif kompetensi dasar pemasangan sistem penerangan dan wiring kelistrikan layak digunakan; (2 kualitas multimedia interaktif ini sangat baik, hasil penilaian ahli ditinjau dari pembelajaran 66 (baik, isi sebesar 54 (baik, aspek tampilan 97 (baik, dan program 50 (baik, sedangkan hasil dari penilaian peserta didik uji coba lapangan pada aspek pembelajaran1277 (sangat baik, isi 1195 (sangat baik, tampilan 1562 (sangat baik, dan pemograman 519 (sangat baik; (3 Produk multimedia pembelajaran interaktif kompetensi dasar pemasangan sistem penerangan dan wiring kelistrikan efektif meningkatkan hasil belajar siswa. Rata-rata penilaian hasil belajar siswa ketika pretest adalah 63,75 dengan nilai terendah 50 dan nilai tertinggi 75. Sedangkan rata-rata nilai posttest sebesar 78,75 dengan nilai terendah 65 dan nilai tertinggi 90.

  10. Perancangan Implementasi E-Learning Berbasis Moodle Dalam Matakuliah Statistika Program Studi Pendidikan Teknik Informatika Dan Komputer

    Directory of Open Access Journals (Sweden)

    Affni Syaviera Nova

    2017-06-01

    Full Text Available Penelitian dilakukan dengan tujuan merancang implementasi e-learning berbasis Moodle berupa website dalam matakuliah Statistika program studi Pendidikan Teknik Informatika dan Komputer. Sistem e-learning ini dirancang untuk diimpelementasikan pada semua matakuliah yang ada pada program studi Pendidikan Teknik Informatika dan Komputer, sehingga membantu kegiatan perkuliahan. Sebagai pengembangan awal, sistem e- learning ini diuji coba pada matakuliah statistika. Penelitian ini menggunakan desain penelitian dan pengembangan (Research and Development menurut Sugiyono (2010. Subyek penelitian yaitu dosen statistika dan mahasiswa yang telah mengikuti perkuliahan Statistika ditentukan secara purposive sampling. Data yang diambil adalah kelayakan dari segi materi dan media melalui angket, dan tanggapan mahasiswa melalui angket. Tanggapan ahli menunjukkan e-learning berbasis Moodle sangat baaik dari segi media dan bagus dari segi materi. Hasil angket tanggapan siswa pada uji coba skala kecil menunjukkan bahwa mayoritas siswa memberikan tanggapan positif terhadap kegiatan pembelajaran menggunakan media e-learning berbasis Moodle. Produk final e-learning berbasis Moodle berisi modul, video, ppt, chat, kelas virtual dan forum diskusi. Berbagai konten dan fasilitas yang dimiliki e-learning yang dikembangkan membuat pembelajaran Sistem Gerak menjadi lebih menarik. Berdasarkan hasil analisis dan pembahasan dapat disimpulkan bahwa e-learning berbasis Moodle sesuai dan layak diterapkan pada matakuliah Statistika.

  11. QuickASP: PEMBANGKIT KODE PROGRAM ASP UNTUK APLIKASI BASIS DATA BERBASIS WEB

    Directory of Open Access Journals (Sweden)

    Imam Kuswardayan

    2007-01-01

    Full Text Available Dalam pembuatan sistem aplikasi basis data berbasis web, perancangan antarmuka pengguna (presentation layer dan lapisan bisnis (bussiness layer merupakan tahap yang dilalui setelah pemahaman terhadap kebutuhan pengguna sistem. Adanya pola atau keteraturan dalam implementasi tahap ini menyebabkan pengembangan sistem akan lebih efisien jika menggunakan suatu aplikasi yang dapat menghasilkan kerangka dasar aplikasi web dengan cepat untuk kedua lapisan tersebut dan bahkan beserta kode programnya. Pada penelitian ini telah diimplementasikan suatu perangkat lunak yang selanjutnya disebut QuickASP. QuickASP membangkitkan kode ASP untuk membangun  homepage otomatis. Untuk membangkitkan kode ASP, QuickASP membutuhkan komponen berupa basis data dan file Cascading Style Sheets (CSS. Proses awal yang dilakukan QuickASP dalam membangkitkan kode program ASP adalah membaca informasi basis data berupa tabel-tabel, nama field dan tipe data. Setelah itu QuickASP akan membangkitkan file-file ASP beserta file-file pendukungnya berdasarkan hasil pengaturan tampilan halaman web yang dilakukan oleh pengguna.Uji coba QuickASP dilakukan pada tiga jenis basis data yaitu Microsoft Access, Microsoft SQL Server, dan Oracle. Dari hasil uji coba tersebut, QuickASP terbukti dapat membangkitkan homepage otomatis beserta fungsi–fungsi yang disediakan untuk modifikasi record dan fungsi navigasi.Kata kunci: QuickASP, file cascading style sheets, kode program ASP.

  12. Optimized methods to measure acetoacetate, 3-hydroxybutyrate, glycerol, alanine, pyruvate, lactate and glucose in human blood using a centrifugal analyser with a fluorimetric attachment

    OpenAIRE

    Stappenbeck, R.; Hodson, A. W.; Skillen, A. W.; Agius, L.; Alberti, K. G. M. M.

    1990-01-01

    Optimized methods are described for the analysis of glucose, lactate, pyruvate, alanine, glycerol, D-3-hydroxybutyrate and acetoacetate in perchloric acid extracts of human blood using the Cobas Bio centrifugal analyser. Glucose and lactate are measured using the photometric mode and other metabolites using the fluorimetric mode. The intra-assay coefficients of variation ranged from 0.7 to 4.1%, except with very low levels of pyruvate and acetoacetate where the coefficients of variation were ...

  13. Photometric and spectroscopic analysis of the eclipsing binary DS Andromedae - a member of NGC 752

    International Nuclear Information System (INIS)

    Schiller, S.J.; Milone, E.F.

    1988-01-01

    Complete BVRI light curves and radial-velocity curves of both components of the 1.01 d period eclipsing binary DS And are presented. The Wilson-Devinney synthetic light curve program is used to determine the absolute parameters of this system, and it is confirmed that the primary component is nearly filling its Roche lobe. The distance modulus and systemic velocity conclusively establish cluster membership. The age of NGC 752, determined by fitting the theoretical isochrones of VandenBerg (1985) to the C-M diagram of Cannon (1970), is assigned to DS And. This enables a showing that, although the primary component is nearly filling its Roche lobe, it has thus far evolved as a single isolated star. 54 references

  14. Contraction of the solar nebula

    International Nuclear Information System (INIS)

    Rawal, J.J.

    1984-01-01

    The concept of Roche limit is applied to the Laplacian theory of the origin of the solar system to study the contraction of a spherical gas cloud (solar nebula). In the process of contraction of the solar nebula, it is assumed that the phenomenon of supersonic turbulent convection is operative and brings about the halt at various stages of contraction. It is found that the radius of the contracting solar nebula follows the Titius-Bode law. The consequences of the relation are also discussed. The aim is to attempt to explain, on the basis of the concept of Roche limit, the distribution of planets in the solar system and try to understand the physics underlying it. (Auth.)

  15. Mass-loss evolution of close-in exoplanets: Evaporation of hot Jupiters and the effect on population

    Energy Technology Data Exchange (ETDEWEB)

    Kurokawa, H. [Department of Physics, Nagoya Univsersity, Furo-cho, Chikusa-ku, Nagoya, Aichi 464-8602 (Japan); Nakamoto, T., E-mail: kurokawa@nagoya-u.jp [Department of Earth and Planetary Sciences, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8551 (Japan)

    2014-03-01

    During their evolution, short-period exoplanets may lose envelope mass through atmospheric escape owing to intense X-ray and extreme ultraviolet (XUV) radiation from their host stars. Roche-lobe overflow induced by orbital evolution or intense atmospheric escape can also contribute to mass loss. To study the effects of mass loss on inner planet populations, we calculate the evolution of hot Jupiters considering mass loss of their envelopes and thermal contraction. Mass loss is assumed to occur through XUV-driven atmospheric escape and the following Roche-lobe overflow. The runaway effect of mass loss results in a dichotomy of populations: hot Jupiters that retain their envelopes and super Earths whose envelopes are completely lost. Evolution primarily depends on the core masses of planets and only slightly on migration history. In hot Jupiters with small cores (≅ 10 Earth masses), runaway atmospheric escape followed by Roche-lobe overflow may create sub-Jupiter deserts, as observed in both mass and radius distributions of planetary populations. Comparing our results with formation scenarios and observed exoplanets populations, we propose that populations of closely orbiting exoplanets are formed by capturing planets at/inside the inner edges of protoplanetary disks and subsequent evaporation of sub-Jupiters.

  16. Mass-loss evolution of close-in exoplanets: Evaporation of hot Jupiters and the effect on population

    International Nuclear Information System (INIS)

    Kurokawa, H.; Nakamoto, T.

    2014-01-01

    During their evolution, short-period exoplanets may lose envelope mass through atmospheric escape owing to intense X-ray and extreme ultraviolet (XUV) radiation from their host stars. Roche-lobe overflow induced by orbital evolution or intense atmospheric escape can also contribute to mass loss. To study the effects of mass loss on inner planet populations, we calculate the evolution of hot Jupiters considering mass loss of their envelopes and thermal contraction. Mass loss is assumed to occur through XUV-driven atmospheric escape and the following Roche-lobe overflow. The runaway effect of mass loss results in a dichotomy of populations: hot Jupiters that retain their envelopes and super Earths whose envelopes are completely lost. Evolution primarily depends on the core masses of planets and only slightly on migration history. In hot Jupiters with small cores (≅ 10 Earth masses), runaway atmospheric escape followed by Roche-lobe overflow may create sub-Jupiter deserts, as observed in both mass and radius distributions of planetary populations. Comparing our results with formation scenarios and observed exoplanets populations, we propose that populations of closely orbiting exoplanets are formed by capturing planets at/inside the inner edges of protoplanetary disks and subsequent evaporation of sub-Jupiters.

  17. Analysis of HbA1c on an automated multicapillary zone electrophoresis system.

    Science.gov (United States)

    Rollborn, Niclas; Åkerfeldt, Torbjörn; Nordin, Gunnar; Xu, Xiao Yan; Mandic-Havelka, Aleksandra; Hansson, Lars-Olof; Larsson, Anders

    2017-02-01

    Hemoglobin A1c (HbA1c) is a frequently requested laboratory test and there is thus a need for high throughput instruments for this assay. We evaluated a new automated multicapillary zone electrophoresis instrument (Capillarys 3 Tera, Sebia, Lisses, France) for analysis of HbA1c in venous samples. Routine requested HbA1c samples were analyzed immunologically on a Roche c6000 instrument (n = 142) and then with the Capillarys 3 Tera instrument. The Capillarys 3 Tera instrument performed approximately 70 HbA1c tests/hour. There was a strong linear correlation between Capillarys 3 Tera and Roche Tina-Quant HbA1c Gen 3 assay (y = 1.003x - 0.3246 R 2  = .996). The total CV for the 12 capillaries varied between 0.8 and 2.2% and there was a good agreement between duplicate samples (R 2  = .997). In conclusion, the Capillarys 3 Tera instrument has a high assay capacity for HbA1c. It has a good precision and agreement with the Roche Tina-Quant HbA1c method and is well suited for high volume testing of HbA1c.

  18. PENGEMBANGAN MODUL GEOGRAFI PARIWISATA BERBASIS PAKET WISATA PULAU LOMBOK SEBAGAI UPAYA MEMUPUK RASA CINTA TANAH AIR PADA MAHASISWA

    Directory of Open Access Journals (Sweden)

    Andrinata Andrinata

    2016-10-01

    Full Text Available The purpose of the study is to produce the tourism geography module based on the Lombok tourism packages that is prepared in accordance with the module design of C Michael and Stephen J. Page. This study is designed with Dick & Carey model and simplified into six steps. The quality of product is known through the lecturer’s feedback and students during the field test. The trial subjects are the students of Geography Education STKIP Hamzanwadi Selong in the sixth semester in year 2013 who have taken the course. Based on the results of validation and field trials, the numbers of scores are obtained namely: (a the assessment of the expert design towards the components of the module is 82.7%, (b the assessment of the content/materials to components of the module is 83%, (c the assessment of the language expert of language towards the module components is 76%, (d the assessment of the lecturer of the course and students towards the questionnaires is distributed associated with the products and developed each score 84.28% and 86.4%. The average value of the results of validation and field trials, the module is developed and appropriately used as learning sources with percentage 82.5%. Tujuan penelitian ini ialah menghasilkan modul Geografi Pariwisata Berbasis Paket Wisata Pulau Lombok yang disusun sesuai dengan desain modul C. Michael Hall dan Stephen J. Page. Penelitian ini didesain dengan pendekatan penelitian pengembangan model Dick & Carey yang disederhanakan menjadi enam langkah. Kualitas produk diketahui melalui hasil tanggapan dari dosen pengampu matakuliah dan mahasiswa pada saat uji lapangan. Subjek uji coba yakni mahasiswa Program Studi Pendidikan Geografi STKIP Hamzanwadi Selong pada semester VI angkatan 2013 yang telah menempuh matakuliah tersebut. Berdasarkan hasil validasi dan uji coba lapangan, jumlah skor yang didapat yakni: (a penilaian ahli desain pembelajaran terhadap komponen modul adalah 82,7, (b penilaian ahli isi

  19. Pengembangan problem based learning dengan assessment for learning berbantuan smartphone dalam pembelajaran matematika

    Directory of Open Access Journals (Sweden)

    Muhammad Ridlo Yuwono

    2017-11-01

    Full Text Available [Bahasa]: Penelitian ini bertujuan untuk menghasilkan model Problem Based Learning (PBL menggunakan penilaian Assessment for Learning (AfL berbantuan smartphone, disingkat PBL-AfL-S yang valid, praktis dan efektif untuk mendukung implementasi kurikulum 2013 di SMA. Tahap-tahap pengembangan model PBL-AfL-S terdiri dari penelitian pendahuluan, pengembangan/prototiping, dan evaluasi. Kualitas model PBL-AfL-S mengacu pada kriteria kualitas menurut Nieveen (1999 yaitu valid, praktis, dan efektif. Model PBL-AfL-S diujicobakan di SMA Negeri 3 Klaten dalam dua tahap uji coba. Uji coba tahap I dilaksanakan di kelas XI-IPA 6 dan uji coba tahap II dilaksanakan di kelas XI-IPA 7. Instrumen penelitian terdiri dari: 1 Instrumen penilaian kevalidan komponen model dan perangkat pendukung pembelajaran, 2 Instrumen kepraktisan aktivitas guru dan siswa, dan 3 Instrumen keefektifan yang meliputi angket penilaian diri, lembar penilaian proyek, tes prestasi belajar, dan lembar respon siswa. Hasil penelitian menunjukkan bahwa model PBL-AfL-S dan perangkat pembelajarannya telah memenuhi kriteria valid, praktis dan efektif. Kata kunci: Pembelajaran; Masalah; Asesmen; Smartphone [English]: This study aims to develop a Problem Based Learning (PBL model using Assessment for Learning (AFL with smartphone, abbreviated as PBL-AfL-S as valid, practical and effective to support the implementation of the 2013 curriculum in High School. The stages of developing the PBL-AfL-S model consist of preliminary research, development or prototyping, and evaluation. The quality criteria of PBL-AfL-S refer to Nieveen (1999, i.e. valid, practical, and effective. The PBL-AfL-S model was piloted in SMA Negeri 3 Klaten in two phases. Tryout 1 was conducted in class XI-IPA 6 and tryout 2 was in class XI-IPA 7. The research instruments consist of: 1 The validity instrument of the model and its learning support tools, 2 the practicality of the teacher’s and students’ activity, and 3 The

  20. Presidential Green Chemistry Challenge: 2000 Greener Synthetic Pathways Award

    Science.gov (United States)

    Presidential Green Chemistry Challenge 2000 award winner, Roche Colorado, developed a greener synthesis for gancyclovir (Cytovene, a potent antiviral drug) that uses a second-generation Guanine Triester (GTE) process.

  1. 76 FR 59141 - Determination That LOXITANE (Loxapine Succinate) Capsules and Three Other Drug Products Were Not...

    Science.gov (United States)

    2011-09-23

    ... Applicant NDA 017525 LOXITANE (loxapine Watson Laboratories succinate) Inc., 417 Wakara Capsules, Way, Suite.../milliliter. NDA 020828 FORTOVASE Hoffmann La Roche (saquinavir) Inc., 340 Kingsland Capsule, 200 mg. St...

  2. Fractionation list: F0000000120 [jPOST repository metadata[Archive

    Lifescience Database Archive (English)

    Full Text Available sium chloride and PhosSTOP (Roche Diagnostics). The homogenates were centrifuged ...ogenate supernatant fractions were further ultra-centrifuged at 105,000 g to obtain cytosolic fractions from

  3. Fractionation list: F0000000121 [jPOST repository metadata[Archive

    Lifescience Database Archive (English)

    Full Text Available assium chloride and PhosSTOP (Roche Diagnostics). The homogenates were centrifuge...omogenate supernatant fractions were further ultra-centrifuged at 105,000 g to obtain cytosolic fractions fr

  4. Further considerations on contracting solar nebula

    Science.gov (United States)

    Rawal, J. J.

    1986-01-01

    Kepler's third law of the planetary system is analyzed in terms of Prentice's (1978a) modern Laplacian theory and Rawal's (1984) Roche limit concept. Prentice has determined, based on laws of conservation of mass and angular momentum and the concept of supersonic turbulent convection, that the ratio of orbital radii of successively disposed gaseous rings is a constant of approximately 1.69. Rawal studied the relationship between the supersonic turbulent convection concept and Roche limit and established a limit of 1.442. It is concluded that Kepler's law determines the rotation period of the sun at the time of its formation at the present radius to be equal to 0.1216 d. The correlation between orbital periods of the radii and resonant structure is investigated.

  5. Comparison of five methods for extraction of Legionella pneumophila from respiratory specimens.

    Science.gov (United States)

    Wilson, Deborah; Yen-Lieberman, Belinda; Reischl, Udo; Warshawsky, Ilka; Procop, Gary W

    2004-12-01

    The efficiencies of five commercially available nucleic acid extraction methods were evaluated for the recovery of a standardized inoculum of Legionella pneumophila in respiratory specimens (sputum and bronchoalveolar lavage [BAL] specimens). The concentrations of Legionella DNA recovered from sputa with the automated MagNA Pure (526,200 CFU/ml) and NucliSens (171,800 CFU/ml) extractors were greater than those recovered with the manual methods (i.e., Roche High Pure kit [133,900 CFU/ml], QIAamp DNA Mini kit [46,380 CFU/ml], and ViralXpress kit [13,635 CFU/ml]). The rank order was the same for extracts from BAL specimens, except that for this specimen type the QIAamp DNA Mini kit recovered more than the Roche High Pure kit.

  6. HCV infection among Saudi population: high prevalence of genotype 4 and increased viral clearance rate.

    Directory of Open Access Journals (Sweden)

    Ahmed S Abdel-Moneim

    Full Text Available HCV is a major etiological agent of liver disease with a high rate of chronic evolution. The virus possesses 6 genotypes with many subtypes. The rate of spontaneous clearance among HCV infected individuals denotes a genetic determinant factor. The current study was designed in order to estimate the rate of HCV infection and ratio of virus clearance among a group of infected patients in Saudi Arabia from 2008 to 2011. It was additionally designed to determine the genotypes of the HCV in persistently infected patients. HCV seroprevalence was conducted on a total of 15,323 individuals. Seropositive individuals were tested by Cobas AmpliPrep/Cobas TaqMan HCV assay to determine the ratio of persistently infected patients to those who showed spontaneous viral clearance. HCV genotyping on random samples from persistently infected patients were conducted based on the differences in the 5'untranslated region (5'UTR. Anti-HCV antibodies were detected in 7.3% of the totally examined sera. A high percentage of the HCV infected individuals experienced virus clearance (48.4%. HCV genotyping revealed the presence of genotypes 1 and 4, the latter represented 97.6% of the tested strains. Evidences of the widespread of the HCV genotype 4 and a high rate of HCV virus clearance were found in Saudi Arabia.

  7. A novel duplex real-time reverse transcriptase-polymerase chain reaction assay for the detection of hepatitis C viral RNA with armored RNA as internal control

    Directory of Open Access Journals (Sweden)

    Meng Shuang

    2010-06-01

    Full Text Available Abstract Background The hepatitis C virus (HCV genome is extremely heterogeneous. Several HCV infections can not be detected using currently available commercial assays, probably because of mismatches between the template and primers/probes. By aligning the HCV sequences, we developed a duplex real-time reverse transcriptase-polymerase chain reaction (RT-PCR assay using 2 sets of primers/probes and a specific armored RNA as internal control. The 2 detection probes were labelled with the same fluorophore, namely, 6-carboxyfluorescein (FAM, at the 5' end; these probes could mutually combine, improving the power of the test. Results The limit of detection of the duplex primer/probe assay was 38.99 IU/ml. The sensitivity of the assay improved significantly, while the specificity was not affected. All HCV genotypes in the HCV RNA Genotype Panel for Nucleic Acid Amplification Techniques could be detected. In the testing of 109 serum samples, the performance of the duplex real-time RT-PCR assay was identical to that of the COBAS AmpliPrep (CAP/COBAS TaqMan (CTM assay and superior to 2 commercial HCV assay kits. Conclusions The duplex real-time RT-PCR assay is an efficient and effective viral assay. It is comparable with the CAP/CTM assay with regard to the power of the test and is appropriate for blood-donor screening and laboratory diagnosis of HCV infection.

  8. Thermal annealing and pressure effects on BaFe2-xCoxAs2 single crystals.

    Science.gov (United States)

    Shin, Dongwon; Jung, Soon-Gil; Prathiba, G; Seo, Soonbeom; Choi, Ki-Young; Kim, Kee Hoon; Park, Tuson

    2017-11-26

    We investigate the pressure and thermal annealing effects on BaFe2-xCoxAs2 (Co-Ba122) single crystals with x = 0.1 and 0.17 via electrical transport measurements. The thermal annealing treatment not only enhances the superconducting transition temperature (Tc) from 9.6 to 12.7 K for x = 0.1 and from 18.1 to 21.0 K for x = 0.17, but also increases the antiferromagnetic transition temperature (TN). Simultaneous enhancement of Tc and TN by the thermal annealing treatment indicates that thermal annealing could substantially improve the quality of the Co-doped Ba122 samples. Interestingly, Tc of the Co-Ba122 compounds shows a scaling behavior with a linear dependence on the resistivity value at 290 K, irrespective of tuning parameters, such as chemical doping, pressure, and thermal annealing. These results not only provide an effective way to access the intrinsic properties of the BaFe2As2 system, but also may shed a light on designing new materials with higher superconducting transition temperature. © 2017 IOP Publishing Ltd.

  9. The analytic impact of a reduced centrifugation step on chemistry and immunochemistry assays: an evaluation of the Modular Pre-Analytics.

    Science.gov (United States)

    Koenders, Mieke M J F; van Hurne, Marco E J F; Glasmacher-Van Zijl, Monique; van der Linde, Geesje; Westerhuis, Bert W J J M

    2012-09-01

    The COBAS 6000 system can be completed by a Modular Pre-Analytics (MPA), an integrated laboratory automation system that streamlines preanalysis. For an optimal throughput, the MPA centrifuges blood collection tubes for 5 min at 1885 × g - a centrifugation time that is not in concordance with the World Health Organization guidelines which suggest centrifugation for 10/15 min at 2000-3000 × g. In this study, the analytical outcome of 50 serum and 50 plasma samples centrifuged for 5 or 10 min at 1885 × g was investigated. The study included routine chemistry and immunochemistry assays on the COBAS 6000 and the Minicap capillary electrophoresis. Deming-fit and Bland-Altman plots of the 5-min and 10-min centrifugation steps indicated a significant correlation in serum samples. The lipaemia index in plasma samples centrifuged for 5 min displayed a statistically significant variation when compared with the 10-min centrifugation. Preanalytical centrifugation can be successfully down-scaled to a duration of 5 min for most routine chemistry and immunochemistry assays in serum and plasma samples. To prevent inaccurate results in plasma samples with an increased lipaemia index from being reported, the laboratory information system was programmed to withhold results above certain lipaemia indices. The presented data support the use of a 5-min centrifugation step to improve turnaround times, thereby meeting one of the desires of the requesting clinicians.

  10. Performance and Logistical Challenges of Alternative HIV-1 Virological Monitoring Options in a Clinical Setting of Harare, Zimbabwe

    Directory of Open Access Journals (Sweden)

    Pascale Ondoa

    2014-01-01

    Full Text Available We evaluated a low-cost virological failure assay (VFA on plasma and dried blood spot (DBS specimens from HIV-1 infected patients attending an HIV clinic in Harare. The results were compared to the performance of the ultrasensitive heat-denatured p24 assay (p24. The COBAS AmpliPrep/COBAS TaqMan HIV-1 test, version 2.0, served as the gold standard. Using a cutoff of 5,000 copies/mL, the plasma VFA had a sensitivity of 94.5% and specificity of 92.7% and was largely superior to the VFA on DBS (sensitivity = 61.9%; specificity = 99.0% or to the p24 (sensitivity = 54.3%; specificity = 82.3% when tested on 302 HIV treated and untreated patients. However, among the 202 long-term ART-exposed patients, the sensitivity of the VFA decreased to 72.7% and to 35.7% using a threshold of 5,000 and 1,000 RNA copies/mL, respectively. We show that the VFA (either on plasma or on DBS and the p24 are not reliable to monitor long-term treated, HIV-1 infected patients. Moreover, achieving acceptable assay sensitivity using DBS proved technically difficult in a less-experienced laboratory. Importantly, the high level of virological suppression (93% indicated that quality care focused on treatment adherence limits virological failure even when PCR-based viral load monitoring is not available.

  11. PENDIDIKAN KARAKTER BANGSA BERBASIS STRATEGI PEMBELAJARAN PAKEM MELALUI PERMAINAN CINCIN DI JEMPOL TANGAN (Karya Inovasi Pembelajaran Sekolah Dasar

    Directory of Open Access Journals (Sweden)

    Ani Adibatin

    2016-02-01

    Full Text Available Berhasil tidaknya pencapaian tujuan pembelajaran sangat ditentukan oleh kemampuan guru dalam mengelola kelas, mengelola siswa, memilih strategi pembelajaran, serta kebermaknaan dalam memberikan tugas pada siswa. Berkaitan dengan permasalahan tersebut, penulis sebagai pengawas mengembangkan alat permainan inovatif yang bisa dipakai oleh semua guru, baik guru kelas, guru mata pelajaran, maupun guru ekstra kurikuler. Alat permainan ini bisa dipakai oleh semua siswa dari berbagai tingkatan kelas, berbagai tingkat jenjang sekolah, dan untuk pembelajaran materi yang berbeda. Alat permainan inovatif pembelajaran ini dikembangkan dengan tujuan agar peserta didik bisa belajar sambil bermain dan bermain sambil belajar. Disamping itu, untuk membantu para guru dalam menanamkan pendidikan karakter, sehingga peserta didik menjadi anak yang berkarakter, berwatak sesuai dengan nilai-nilai Pancasila demi terwujudnya tujuan pendidikan nasional. Uji coba alat permainan inovatif ini dilakukan di 9 SD binaan Kecamatan Tuntang. Dari hasil uji coba diperoleh temuan bahwa ada perbedaan yang sangat signifikan antara pendidikan karakter pada pembelajaran tanpa alat permainan inovatif dibandingkan dengan pembela-jaran yang menggunakan alat permainan cincin akik di jempol tangan. Nilai rata-rata pembelajaran tanpa alat inovatif 76,55 %, sedangkan nilai rata-rata dengan menggunakan alat permainan cincin akik di jempol sebesar 86,88 %. Hasil pembelajaran menggunakan alat peraga inovatif ini menunjukkan bah-wa melalui strategi pembelajaran PAKEM dengan bermain cincin akik di jempol tangan dapat membangun karakter peserta didik sampai 11,33 %.

  12. Tähelepanu keskmes on viiruslik hepatiit / Marika Kusnets

    Index Scriptorium Estoniae

    Kusnets, Marika

    2008-01-01

    Ülemaailmsel hepatiidipäeval 19. mail korraldasid Eesti Gastroenteroloogide Selts (EGS) ja Roche Eesti OÜ meediakanalite esindajatele ümarlaua, et aidata teadvustada C-hepatiidi ohtu, testimis- ja ravivõimalusi Eestis

  13. Evidence of mother-child transmission of Helicobacter pylori infection Evidência da transmissão mãe-filho da infecção por Helicobacter pylori

    Directory of Open Access Journals (Sweden)

    Mario Luis Escobar

    2004-12-01

    Full Text Available BACKGROUND: Low socioeconomical status is a major risk factor for natural acquisition of Helicobacter pylori (H. pylori infection in developing countries. Its transmission route is unknown but studies suggest person-to-person transmission. AIM: To evaluate seropositivity of anti-H. pylori antibodies in family members of infected symptomatic index patients as compared to family members of symptomatic uninfected index patients. PATIENTS AND METHODS: One hundred and twelve family members of 38 patients who underwent endoscopy to exclude peptic disease were studied. Patients were deemed H. pylori infected or not infected when rapid urease test and histology were both positive or both negative. The family members underwent ELISA serology using the Cobas Core II Kit (Roche and were classified into three groups: I - 29 family members of 10 H. pylori (+ duodenal ulcer index patients; II - 57 family members of 17 H. pylori (+ index patients without duodenal ulcer; III - 26 family members of 11 H. pylori (- index patients. RESULTS: Seropositivity of group I and II (infected patients was higher than the control group, 83% vs 38%, specially in mothers, 81% vs 18%, and in siblings 76% vs 20%. Differences between fathers' seropositivity was not statistically significant in the three groups: 100% vs 86% vs 70%. Seropositivity of all family members (mother, father and siblings between infected group (I vs II was similar. CONCLUSION: Prevalence of H. pylori infection was higher in family members of infected patients, but was similar among family members of infected patients with and without duodenal ulcer. H. pylori infection is more frequent in mothers and siblings of infected index children. A common source of infection cannot be excluded, but facts suggest that person-to-person transmission occurs, specially from mother to child.O estrato socioeconômico baixo é o maior fator de risco para a aquisição natural da infecção por Helicobacter pylori em pa

  14. Le souffre thiophénique dans les pétroles et les extraits de roche. Analyse par spectrométrie de masse et chromatographie en phase gazeuse Mass-Spectrometry and Gas-Chromatography Analysis of Thiophene Sulfur in Oil and Rock Extracts

    Directory of Open Access Journals (Sweden)

    Castex H.

    2006-11-01

    Full Text Available On étudie par spectrométrie de masse à haute résolution la répartition du soufre thiophénique par coupe de distillation et par nombre de carbone dans la fraction > C10 d'un pétrole brut. Parallèlement on chromatographie à l'aide d'un détecteur sélectif à photométrie de flamme les diverses fractions thiophéniques. L'examen des chromatogrammes permet de déterminer les zones dé réponse et l'allure générale des différentes coupes thiophéniques. Les applications sont variées : on vérifie le bien-fondé de l'utilisation d'un spectromètre de masse à basse résolution pour les analyses en routine d'huiles brutes et on peut, par la connaissance des différents profils de type thiophénique prévoir des analogies ou des différences au sein d'huiles brutes et d'extraits de roche d'un même bassin pétrolier, ce qui limite le nombre d'échantillons à analyser en détail. High-resolution mass spectrometry is used to analyze the distribution of thiophenic sulfur per distillation cut and per carbon number in the > C10 fraction of a crude oil. At the same time, a selective flame-photometry sensor is used to chromatograph the different thiophenic fractions. An analysis of the chromatograms serves to determine the response zones and the general aspect of the different thiophenic cuts. There are various applications of this process. The validity of using a low-resolution mass spectrometer is checked for routine crude-cil analyses. By determining the different profiles of the thiophenic type, similarities or differences can be predicted in the crude cils and rock extracts from the saure cil basin. This limits the number of samples having to be analyzed in detail.

  15. 77 FR 27777 - Agency Information Collection Activities: Proposed Collection; Comment Request

    Science.gov (United States)

    2012-05-11

    ... Hours: 1,217. (For policy questions regarding this collection contact Kim Roche at 410- 786-3524. For... include the bundling of separately billed drugs, clinical laboratory tests, and other items ``to maximum...

  16. Sequence Read Archive (SRA)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Sequence Read Archive (SRA) stores raw sequencing data from the next generation of sequencing platforms including Roche 454 GS System®, Illumina Genome...

  17. Effekten af sund skolekost på udvalgte blodparametre

    DEFF Research Database (Denmark)

    Horn, Peer Bendix; Brandslund, Ivan; Schmedes, Anne

    2009-01-01

    blood before (week 39) and after the intervention (week 49). The intervention group received a healthy meal for two months (25-30% of the daily intake of calories). Blood samples were analyzed for 17 parameters related to carbohydrate, fat and protein metabolism as well as vitamins and minerals. RESULTS......: During the intervention period, the intervention group showed a significant change in mean values for thyroid-stimulating hormone (TSH), calcium (CA) haemoglobin (HB), cobalamin (COBA) and creatinine (CREA) compared with the control group (p

  18. EPL-i ümarlaud : kõige olulisem on vähi varajane avastamine / Ille Grün-Ots

    Index Scriptorium Estoniae

    Grün-Ots, Ille, 1960-2016

    2007-01-01

    Ümarlaual osalesid TÜ kliinikumi hematoloogia-onkoloogiakliiniku professor Hele Everaus, ravimifirma Roche Eesti OÜ tegevjuht Kadri Mägi, ravifirma GlaxoSmithKline Eesti filiaali juhataja Akshay Mody ja PERH-i keemiaravispetsialist Helis Pokker

  19. Molecular study and phylogenetic analysis of Mycoplasma synoviae ...

    African Journals Online (AJOL)

    Dr.Hosseini

    2012-01-26

    Jan 26, 2012 ... 4Clinical Sciences Department, Faculty of Veterinary Science, University of Tehran, Iran. .... France) in 2% agarose (Agarose MP, Roche) gel in TAE buffer. ... were performed with sequencing project management and.

  20. REFINED NEUTRON STAR MASS DETERMINATIONS FOR SIX ECLIPSING X-RAY PULSAR BINARIES

    International Nuclear Information System (INIS)

    Rawls, Meredith L.; Orosz, Jerome A.; McClintock, Jeffrey E.; Torres, Manuel A. P.; Bailyn, Charles D.; Buxton, Michelle M.

    2011-01-01

    We present an improved method for determining the mass of neutron stars in eclipsing X-ray pulsar binaries and apply the method to six systems, namely, Vela X-1, 4U 1538-52, SMC X-1, LMC X-4, Cen X-3, and Her X-1. In previous studies to determine neutron star mass, the X-ray eclipse duration has been approximated analytically by assuming that the companion star is spherical with an effective Roche lobe radius. We use a numerical code based on Roche geometry with various optimizers to analyze the published data for these systems, which we supplement with new spectroscopic and photometric data for 4U 1538-52. This allows us to model the eclipse duration more accurately and thus calculate an improved value for the neutron star mass. The derived neutron star mass also depends on the assumed Roche lobe filling factor β of the companion star, where β = 1 indicates a completely filled Roche lobe. In previous work a range of β between 0.9 and 1.0 was usually adopted. We use optical ellipsoidal light-curve data to constrain β. We find neutron star masses of 1.77 ± 0.08 M sun for Vela X-1, 0.87 ± 0.07 M sun for 4U 1538-52 (eccentric orbit), 1.00 ± 0.10 M sun for 4U 1538-52 (circular orbit), 1.04 ± 0.09 M sun for SMC X-1, 1.29 ± 0.05 M sun for LMC X-4, 1.49 ± 0.08 M sun for Cen X-3, and 1.07 ± 0.36 M sun for Her X-1. We discuss the limits of the approximations that were used to derive the earlier mass determinations, and we comment on the implications our new masses have for observationally refining the upper and lower bounds of the neutron star mass distribution.

  1. PENGEMBANGAN PERANGKAT PEMBELAJARAN MATERI PECAHAN BERBASIS TEORI BRUNER DI KELAS IV SD LABSCHOOL UNESA

    Directory of Open Access Journals (Sweden)

    Lina Wijayanti

    2015-07-01

    Full Text Available Penelitian ini bertujuan untuk menghasilkan perangkat pembelajaran pada materi pecahan tema 3 berbasis teori Bruner ditinjau dari kualitas produk secara umum (kevalidan, kepraktisan, dan keefektifan dan dalam peningkatan kemampuan pemecahan masalah dan prestasi belajar peserta didik di kelas IV SD Labschool Unesa. Penelitian ini termasuk penelitian dan pengembangan yang menggunakan model yang dikembangkan oleh Borg & Gall. Subjek penelitian dalam uji coba terbatas berjumlah 4 siswa, sedangkan dalam uji coba lapangan berjumlah 8 siswa. Subjek uji coba produk operasional pada kelas eksperimen sebanyak 17 siswa dan kelas kontrol sebanyak 18 siswa. Pengumpulan data dalam penelitian ini menggunakan lembar penilaian produk perangkat pembelajaran, lembar observasi guru, lembar observasi peserta didik, tes hasil belajar, angket respon guru, dan agket respon peserta didik. Analisis data menggunakan independent sample t-test dengan taraf signifikansi 0,05. Hasil penelitian menunjukkan bahwa perangkat pembelajaran hasil pengembangan dinyatakan valid dengan kategori sebagai berikut: silabus berkategori baik, RPP berkategori sangat baik, tes hasil belajar berkategori baik, dan media berkategori sangat baik, sehingga rerata hasil semua perangkat pembelajaran adalah berkategori baik. Penerapan perangkat pembelajaran secara umum dapat terlaksana dengan baik. Berdasarkan hasil uji coba kelas eksperimen dan kelas kontrol, terdapat perbedaan yang signifikan pada ketercapaian hasil belajar sehingga perangkat pembelajaran dikatakan efektif, sedangkan untuk kemampuan pemecahan masalah dan prestasi belajar siswa yang mengikuti pembelajaran menggunakan perangkat pembelajaran berbasis teori Bruner hasil pengembangan mengalami peningkatan. Kata Kunci: perangkat pembelajaran, teori Bruner, kemampuan pemecahan masalah, prestasi belajar DEVELOPING TEACHING KIT BASED ON THE THEORY OF BRUNER IN GRADE FOUR STUDENTS OF SD LABSCHOOL UNESA Abstract This study aims to develop a

  2. Expression of human interferon gamma in Brassica napus seeds

    African Journals Online (AJOL)

    TUOYO

    2010-08-09

    Aug 9, 2010 ... resulted band was purified using the agarose gel DNA extraction kit. (Roche). ..... rape seed napin structure and potential roles of the storage protein. ... the sensitivity of progressive multiple sequence alignment through.

  3. Chromosomal localization of rDNA genes and genomic organization ...

    Indian Academy of Sciences (India)

    2State Key Laboratory of Freshwater Ecology and Biotechnology, Institute of Hydrobiology,. Chinese Academy of ... promising model system for understanding the genetic basis .... from sheep (Roche, Mannheim, Germany) at 5 /g/mL. Chro-.

  4. Estimations of bone maturation and calculations of prediction of adult height as tools for the evaluation of growth disorders

    Energy Technology Data Exchange (ETDEWEB)

    Zachmann, M

    1982-03-01

    The methods of estimation of bone maturation (Greulich and Pyle, Tanner et al.) and the possibilities for the calculation of future adult heigth (Bayley and Pinneau, Roche et al., Tanner et al.) are briefly described and their advantages and disadvantages in normal children and in children with growth disorders are discussed. In normal children, all methods provide valuable results, but there are small differences of precision depending on whether the pubertal development is early, average, or late. In pathological conditions, however, as e.g. in precocious puberty or in girls with Turner syndrome, the methods of Roche et al. and of Tanner et al. may overestimate adult height considerably, while that of Bayley and Pinneau remains reasonably accurate. A computerized system, which facilitates the complicated and time-consuming calculations is briefly presented.

  5. A PIONIER and Incisive Look at the Interacting Binary SS Lep

    Science.gov (United States)

    Blind, N.; Boffin, H. M. J.; Berger, J.-P.; Lebouquin, J.-B.; Mérand, A.

    2011-09-01

    Symbiotic stars are excellent laboratories to study a broad range of poorly understood physical processes, such as mass loss of red giants, accretion onto compact objects, and evolution of nova-like outbursts. As their evolution is strongly influenced by the mass transfer episodes, understanding the history of these systems requires foremost to determine which process is at play: Roche lobe overflow, stellar wind accretion, or some more complex mixture of both. We report here an interferometric study of the symbiotic system SS Leporis, performed with the unique PIONIER instrument. By determining the binary orbit and revisiting the parameters of the two stars, we show that the giant does not fill its Roche lobe, and that the mass transfer most likely occurs via the accretion of an important part of the giant's wind.

  6. On Coba and Cocok: youth-led drug-experimentation in Eastern Indonesia.

    Science.gov (United States)

    Hardon, Anita; Idrus, Nurul Ilmi

    2014-01-01

    The everyday lives of contemporary youths are awash with drugs to boost pleasure, moods, sexual performance, vitality, appearance and health. This paper examines pervasive practices of chemical 'self-maximization' from the perspectives of youths themselves. The research for this paper was conducted among male, female and transgender (male to female, so-called waria) sex workers in Makassar, Indonesia. It presents the authors' ethnographic findings on how these youths experiment with drugs to achieve their desired mental and bodily states: with the painkiller Somadril to feel happy, confident and less reluctant to engage in sex with clients, and contraceptive pills and injectable hormones to feminize their male bodies and to attract customers. Youths are extremely creative in adjusting dosages and mixing substances, with knowledge of the (mostly positive) 'lived effects' of drugs spreading through collective experimentation and word of mouth. The paper outlines how these experimental practices differ from those that have become the gold standard in biomedicine.

  7. On Coba and Cocok: youth-led drug-experimentation in Eastern Indonesia

    NARCIS (Netherlands)

    Hardon, A.; Idrus, N.I.

    2014-01-01

    The everyday lives of contemporary youths are awash with drugs to boost pleasure, moods, sexual performance, vitality, appearance and health. This paper examines pervasive practices of chemical ‘self-maximization’ from the perspectives of youths themselves. The research for this paper was conducted

  8. Studi dan Uji Coba Teknologi Bluetooth sebagai Alternatif Komunikasi Data Nirkabel

    OpenAIRE

    Yulia, Yulia; Santoso, Leo Willyanto

    2004-01-01

    In Bahasa Indonesia : Bluetooth adalah suatu teknologi baru yang mulai dikenal dan digunakan. Teknologi ini memberikan Perubahan yang signifikan terhadap peralatan elektronik yang kita gunakan. Jika kita melihat sekeliling kita dimana keyboard dihubungkan pada komputer. Demikian juga halnya dengan printer, mouse, monitor dan lain sebagainya. Semua peralatan itu dihubungkan dengan menggunakan kabel. Akibatnya terjadi masalah banyak kabel yang dibutuhkan di kantor, rumah atau tempat-tempat...

  9. STUDI DAN UJI COBA TEKNOLOGI BLUETOOTH SEBAGAI ALTERNATIF KOMUNIKASI DATA NIRKABEL

    Directory of Open Access Journals (Sweden)

    Yulia Yulia

    2004-01-01

    Full Text Available Bluetooth is a new emerging technology. This technology gives significant changes for electronic devices that we are using. If we look around, a keyboard is connected to a computer. So does a printer, a mouse, a monitor and so on. This condition creates a problem of so many scattered wires installed in the offices, houses and other places. Another problem is how to inspect the damaging or boken wires. In this paper, we will have a discussion on specific applications of bluetooth such as services provided by the bluetooth technology; bluetooth method - how bluetooth devices make connections in a piconet; as well as investigation on bluetooth protocol stack. Bluetooth has succesfully built easy connection among devices from many vendor without using cables, with less power dan money. By using bluetooth, we can build small network or Piconet, consisting of several devices without cables. Abstract in Bahasa Indonesia : Bluetooth adalah suatu teknologi baru yang mulai dikenal dan digunakan. Teknologi ini memberikan perubahan yang signifikan terhadap peralatan elektronik yang kita gunakan. Jika kita melihat sekeliling kita dimana keyboard dihubungkan pada komputer. Demikian juga halnya dengan printer, mouse, monitor dan lain sebagainya. Semua peralatan itu dihubungkan dengan menggunakan kabel. Akibatnya terjadi masalah banyak kabel yang dibutuhkan di kantor, rumah atau tempat-tempat lainnya. Masalah lain yang ditemui adalah bagaimana menelusuri kabel-kabel yang terpasang jika ada suatu kesalahan atau kerusakan. Bluetooth memperbaiki penggunaan teknologi kabel yang cenderung menyulitkan ini dengan cara menghubungkan beberapa peralatan tanpa menggunakan kabel. Pada karya tulis ini, dibahas aplikasi spesifik bluetooth, antara lain servis-servis apa saja yang disediakan oleh teknologi bluetooth; cara kerja bluetooth yaitu bagaimana bluetooth device melakukan koneksi di dalam sebuah piconet serta bluetooth protocol stack. Bluetooth telah berhasil memudahkan koneksi antar beberapa alat dari berbagai vendor tanpa kabel dengan tenaga yang kecil serta biaya yang ringan. Dengan bluetooth dapat dibentuk sebuah jaringan kecil atau Piconet yang terdiri dari beberapa peralatan dan sekali lagi, tanpa memerlukan kabel. Kata kunci: Bluetooth, Bluetooth Protocol Stack, Piconet, Komunikasi data, Nirkabel.

  10. Photometric Analysis and Period Investigation of the EW Type ...

    Indian Academy of Sciences (India)

    Photometric Analysis and Period Investigation of the EW Type. Eclipsing ... binary with the less massive secondary component filling the inner Roche lobe. ..... Cox 2000) assuming that the primary component is a normal main sequence star.

  11. Analytical verification and quality assessment of the Tosoh HLC-723GX HbA1c analyzer

    Directory of Open Access Journals (Sweden)

    Marko Ris

    2017-04-01

    Full Text Available Objectives: Ion-exchange high-performance liquid chromatography (IE-HPLC has long been used as a reproducible and versatile analytical tool for HbA1c measurement.In this study, we performed analytical verification and quality assessment of the recently introduced small IE-HPLC Tosoh HLC-723GX HbA1c analyzer, and a comparison of results to immunoassay (IA and capillary electrophoresis (CE. Design and methods: The total imprecision of Tosoh HLC-723GX was verified according to CLSI EP15-A2 protocol using commercial control materials (C-QC and pooled human whole blood samples (HWB. The Sigma metric was used for the evaluation of quality targets. HbA1c results were compared to automated CE (MiniCap Flex Piercing, Sebia, France and IA (Tina-quant HbA1c Gen 2, Cobas Integra 400+, Roche Diagnostics, USA procedures. Results: The total imprecision of Tosoh HLC-723GX-HbA1c for IFCC(mmol/mol and NGSP(% units was: 1.91/1.25% (HbA1c=31 mmol/mol/5.0% and 0.51/0.63% (HbA1c=84 mmol/mol/9.8% for C-QC, and 0.39/0.2% (HbA1c=47 mmol/mol/6.5% and 0.77/0.46% (HbA1c=94 mmol/mol/10.8% in HWB samples, respectively. Bland-Altman analysis did not reveal any deviation of the results between Tosoh HLC-723GX and CE: mean difference 0.0% (95%CI: −0.02927 to 0.02653%, while the mean HbA1c difference against IA was −0.07% (95%CI: −0.1039 to −0.02765. At the selected HbA1c clinical decision level (48 mmol/mol/6,5%, six sigma analysis gave σ value of 3.91, within a desirable classification of performance. Conclusion: The analytical performance of the Tosoh HLC-723GX complies with the rigorous quality criteria for clinical use of HbA1c, with the results comparable to the CE procedure. Tosoh HLC-723GX provides a plausible analytical choice for reliable HbA1c measurement in low-volume laboratories. Keywords: HbA1c, Quality targets, Six sigma, Tosoh HLC-723GX analyzer

  12. Blood gas sample spiking with total parenteral nutrition, lipid emulsion, and concentrated dextrose solutions as a model for predicting sample contamination based on glucose result.

    Science.gov (United States)

    Jara-Aguirre, Jose C; Smeets, Steven W; Wockenfus, Amy M; Karon, Brad S

    2018-05-01

    Evaluate the effects of blood gas sample contamination with total parenteral nutrition (TPN)/lipid emulsion and dextrose 50% (D50) solutions on blood gas and electrolyte measurement; and determine whether glucose concentration can predict blood gas sample contamination with TPN/lipid emulsion or D50. Residual lithium heparin arterial blood gas samples were spiked with TPN/lipid emulsion (0 to 15%) and D50 solutions (0 to 2.5%). Blood gas (pH, pCO2, pO2), electrolytes (Na+, K+ ionized calcium) and hemoglobin were measured with a Radiometer ABL90. Glucose concentration was measured in separated plasma by Roche Cobas c501. Chart review of neonatal blood gas results with glucose >300 mg/dL (>16.65 mmol/L) over a seven month period was performed to determine whether repeat (within 4 h) blood gas results suggested pre-analytical errors in blood gas results. Results were used to determine whether a glucose threshold could predict contamination resulting in blood gas and electrolyte results with greater than laboratory-defined allowable error. Samples spiked with 5% or more TPN/lipid emulsion solution or 1% D50 showed glucose concentration >500 mg/dL (>27.75 mmol/L) and produced blood gas (pH, pO 2 , pCO 2 ) results with greater than laboratory-defined allowable error. TPN/lipid emulsion, but not D50, produced greater than allowable error in electrolyte (Na + ,K + ,Ca ++ ,Hb) results at these concentrations. Based on chart review of 144 neonatal blood gas results with glucose >250 mg/dL received over seven months, four of ten neonatal intensive care unit (NICU) patients with glucose results >500 mg/dL and repeat blood gas results within 4 h had results highly suggestive of pre-analytical error. Only 3 of 36 NICU patients with glucose results 300-500 mg/dL and repeat blood gas results within 4 h had clear pre-analytical errors in blood gas results. Glucose concentration can be used as an indicator of significant blood sample contamination with either TPN

  13. Definition of the upper reference limit for thyroglobulin antibodies according to the National Academy of Clinical Biochemistry guidelines: comparison of eleven different automated methods.

    Science.gov (United States)

    D'Aurizio, F; Metus, P; Ferrari, A; Caruso, B; Castello, R; Villalta, D; Steffan, A; Gaspardo, K; Pesente, F; Bizzaro, N; Tonutti, E; Valverde, S; Cosma, C; Plebani, M; Tozzoli, R

    2017-12-01

    In the last two decades, thyroglobulin autoantibodies (TgAb) measurement has progressively switched from marker of thyroid autoimmunity to test associated with thyroglobulin (Tg) to verify the presence or absence of TgAb interference in the follow-up of patients with differentiated thyroid cancer. Of note, TgAb measurement is cumbersome: despite standardization against the International Reference Preparation MRC 65/93, several studies demonstrated high inter-method variability and wide variation in limits of detection and in reference intervals. Taking into account the above considerations, the main aim of the present study was the determination of TgAb upper reference limit (URL), according to the National Academy of Clinical Biochemistry guidelines, through the comparison of eleven commercial automated immunoassay platforms. The sera of 120 healthy males, selected from a population survey in the province of Verona, Italy, were tested for TgAb concentration using eleven IMA applied on as many automated analyzers: AIA-2000 (AIA) and AIA-CL2400 (CL2), Tosoh Bioscience; Architect (ARC), Abbott Diagnostics; Advia Centaur XP (CEN) and Immulite 2000 XPi (IMM), Siemens Healthineers; Cobas 6000 (COB), Roche Diagnostics; Kryptor (KRY), Thermo Fisher Scientific BRAHMS, Liaison XL (LIA), Diasorin; Lumipulse G (LUM), Fujirebio; Maglumi 2000 Plus (MAG), Snibe and Phadia 250 (PHA), Phadia AB, Thermo Fisher Scientific. All assays were performed according to manufacturers' instructions in six different laboratories in Friuli-Venezia Giulia and Veneto regions of Italy [Lab 1 (AIA), Lab 2 (CL2), Lab 3 (ARC, COB and LUM), Lab 4 (CEN, IMM, KRY and MAG), Lab 5 (LIA) and Lab 6 (PHA)]. Since TgAb values were not normally distributed, the experimental URL (e-URL) was established at 97.5 percentile according to the non-parametric method. TgAb e-URLs showed a significant inter-method variability. Considering the same method, e-URL was much lower than that suggested by manufacturers (m

  14. Absorption of high-dose enteral vitamin A in low- birth-weight ...

    African Journals Online (AJOL)

    essential for epithelial cell differentiation, it is hypothesised ... produce maximum benefits. As a dose of 50 000 ... injections in such tiny infants has many disadvantages,. inclUding .... Mike Brown, Roche Products, South Africa for the generous.

  15. Vanemuine otsib teed head teatrit hindava vaatajani / Sven Karja ; interv. Margot Visnap

    Index Scriptorium Estoniae

    Karja, Sven, 1968-

    2008-01-01

    Vanemuise eesseisvast hooajast. 27. sept. Tartu Sadamateatris esietendunud Donald Margulies' draamast "Kogutud teosed", lavastaja Eva Klemets; novembris esietendusvast Billy Roche'i "Vaene loom vihma käes", lavastaja Liisa Smith ja teistest uuslavastustest lühidalt

  16. Evidence of cross gene regulation of some virulence factors of ...

    African Journals Online (AJOL)

    David Mtz

    2013-07-10

    Jul 10, 2013 ... They are largely responsible for chronic periodontal disease. .... nucleotide sequence is not reported by the manufacturer (Roche). Previous to the use of .... thesis of different metabolic pathways; in the case of downregulated ...

  17. Tere tulemast tagasi, uue põlvkonna utopistid! / Veronika Valk

    Index Scriptorium Estoniae

    Valk, Veronika, 1976-

    2011-01-01

    Francois Roche ja Eva Castro tulevikuarhitektuuri käsitlevatest ettekannetest Tallinna arhitektuuribiennaali raames toimunud sümpoosionil. Maketinäitus "Viini eksiilid. Helisev arhitektuur" Heliose kinos. Eksponeeritakse Viini Die Angewandte arhitektuurikoolis (juht Hani Rashid) õppivate eestlaste loomingut

  18. Diagnostic efficacy of a real time-PCR assay for Chlamydia trachomatis infection in infertile women in north India

    Directory of Open Access Journals (Sweden)

    Benu Dhawan

    2014-01-01

    Full Text Available Background & objectives: Little is known about the prevalence of Chlamydia trachomatis infection in Indian women with infertility. To improve the diagnosis of C. trachomatis infection in developing countries, there is an urgent need to establish cost-effective molecular test with high sensitivity and specificity. This study was conducted to determine the diagnostic utility of a real time-PCR assay for detention of C. trachomatis infection in infertile women attending an infertility clinic in north India. The in house real time-PCR assay was also compared with a commercial real-time PCR based detection system. Methods: Endocervical swabs, collected from 200 infertile women were tested for C. trachomatis by three different PCR assays viz. in-house real time-PCR targeting the cryptic plasmid using published primers, along with omp1 gene and cryptic plasmid based conventional PCR assays. Specimens were also subjected to direct fluorescence assay (DFA and enzyme immunoassay (EIA Performance of in-house real time-PCR was compared with that of COBAS Taqman C. trachomatis Test, version 2.0 on all in-house real time-PCR positive sample and 30 consecutive negative samples. Results: C. trachomatis infection was found in 13.5 per cent (27/200 infertile women by in-house real time-PCR, 11.5 per cent (23/200 by cryptic plasmid and/or omp1 gene based conventional PCR, 9 per cent (18/200 by DFA and 6.5 per cent (7/200 by EIA. The in-house real time-PCR exhibited a sensitivity and specificity of 100 per cent, considering COBAS Taqman CT Test as the gold standard. The negative and positive predictive values of the in-house real time-PCR were 100 per cent. The in-house real time-PCR could detect as low as 10 copies of C. trachomatis DNA per reaction. Interpretation & conclusions: In-house real time-PCR targeting the cryptic plasmid of C. trachomatis exhibited an excellent sensitivity and specificity similar to that of COBAS Taqman CT Test, v2.0 for detection of C

  19. PERANGKAT PEMBELAJARAN PERISTIWA ALAM DENGAN MODEL COOPERATIVE LEARNING TIPE INSIDE OUTSIDE CIRCLE

    Directory of Open Access Journals (Sweden)

    Diah Sunarsih

    2015-08-01

    Full Text Available Tujuan penelitian ini menghasilkan perangkat pembelajaran IPA dengan model pembelajaran cooperative learning tipe inside outside circle untuk dapat meningkatkan kemampuan berpikir kognitif dan menumbuhkan kemampuan komunikasi ilmiah siswa yang valid materi peristiwa alam. Uji coba skala terbatas dilakukan di SDN 02 Ambowetan. Uji coba skala luas kelas eksperimen SDN 01 Ambowetan VA, sedangkan kelas kontrol SDN 01 Ambowetan VB. Desain uji coba penelitian ini nonequivalent control group design. Prosedur pengembangan dan penelitian dikembangkan mengacu model pengembangan Dick dan Carry terdiri 4 tahap yaitu define, design, develop, dan disseminate. Hasil penelitian diperoleh pengembangan perangkat pembelajaran menerapkan model pembelajaran cooperative learning tipe inside outside circle berupa silabus, RPP, bahan ajar, lembar tes formatif, lembar observasi kemampuan komunikasi ilmiah, dan angket respon siswa valid, efektif, dan praktis diterapkan dalam pembelajaran IPA kelas V sekolah dasar materi peristiwa alam. Perangkat pembelajaran valid dengan nilai skor validitas akhir 3,43. Perangkat pembelajaran efektif terlihat peningkatan hasil uji N-gain menunjukkan hasil 0,50 pada klasifikasi tingkat sedang dan prosentase kemampuan ilmiah kelas eksperimen hasil sebesar 82%. Kriteria praktis dari nilai angket menunjukkan respon siswa kelas eksperimen lebih tinggi dibandingkan kelas kontrol (73% > 67 %.Purpose of this study is produce device the learning cooperative learning type inside outside circle to improve cognitive ability students and foster communication skills scientific a valid on material natural events. Trials limited scale in the SDN 02 Ambowetan. Trials wide scale for experimental class in the SDN 01 Ambowetan 5A, while the control class SDN 01 Ambowetan 5B. Design wide scale nonequivalent control group design. Procedures the development and developed research Dick and Carry consisting of 4 stage define, design, develop, and disseminate

  20. Nematic fluctuations and resonance in iron-based superconductors

    Science.gov (United States)

    Gallais, Yann

    The spontaneous appearance of nematicity, a state of matter that breaks rotation but not translation symmetry, is ubiquitous in many iron based superconductors (Fe SC), and has relevance for the cuprates as well. Here I will review recent electronic Raman scattering experiments which report the presence of critical nematic fluctuations in the charge channel in the tetragonal phase of several Fe SC systems. In electron doped Co-BaFe2As2 (Co-Ba122), these fluctuations extend over most of the superconducting dome. Their associated nematic susceptibility shows Curie-Weiss behavior, and its doping dependence suggests the presence of a nematic quantum critical point near optimal TC Similar nematic fluctuations are also observed in FeSe despite the absence of magnetic order, raising the question of the link between nematicity and magnetism in Fe SC. In FeSe I will further contrast the evolution of nematic fluctuations under isoelectronic S substitution and hydrostatic pressures up to 8 GPa, with only the former showing evidence for a nematic quantum critical point. In the superconducting state of Co-Ba122, I will show that a resonance emerges in the Raman spectra near the nematic quantum critical point. This nematic resonance is a clear fingerprint of the coupling between nematic fluctuations and Bogoliubov quasiparticles, and can be thought as the nematic counterpart of the spin resonance observed in neutron scattering experiments. Support from Agence Nationale de la Recherche via ANR Grant ''Pnictides'' is acknowledged.

  1. PENERAPAN ALGORITMA C4.5 UNTUK PREDIKSI PENGGUNAAN JENIS KONTRASEPSI BERBASIS WEB

    Directory of Open Access Journals (Sweden)

    Rusda Wajhillah

    2017-09-01

    Keluarga Berencana (KB merupakan suatu program pemerintah yang dirancang untuk menyeimbangkan antara kebutuhan dan jumlah penduduk dengan menggunakan alat kontrasepsi. Kurangnya pengetahuan tentang kontrasepsi menyebabkan tidak sedikit akseptor lebih memilih menggunakan kontrasepsi berdasarkan coba-coba atau bahkan mengikuti saran dari orang lain yang kurang paham terhadap alat kontrasepsi. Oleh sebab itu, diperlukan adanya tindakan/penanganan khusus untuk mempermudah para akseptor dalam memilih kontrasepsi yang efektif dan sesuai dengan kondisi tubuhnya. Algoritma C4.5 yaitu metode pohon keputusan mengubah fakta yang sangat besar menjadi pohon keputusan yang merepresentasikan aturan. Aturan dapat dengan mudah dipahami dengan bahasa alami.Untuk itu, dalam penelitian ini akan dilakukan analisa data penggunaan jenis kontrasepsi menggunakan klasifikasi data mining yakni algoritma C4.5 dengan menggunakan beberapa parameter diantaranya usia, jumlah anak, tekanan darah dan riwayat penyakit yang akan diaplikasikan dalam bentuk web guna mempermudah para akseptor dalam mendapatkan nilai informasi yang lebih cepat dan fleksibel. Dari 130 jumlah kasus yang terdiri dari 104 kasus akseptor pengguna kontrasepsi hormonal dan 26 kasus pengguna kontrasepsi non hormonal yang didapat dari Posyandu Desa Nyangkowek Kecamatan Cicurug, maka didapatkan 14 rule yang dihasilkan dari pohon keputusan algoritma C4.5 dengan jumlah class non hormonal sebanyak 8 rule dan jumlah class hormonal sebanyak 6 rule serta dievaluasi dengan pengujian Cross Validation yangmenghasilkan tingkat akurasi sebesar 85,38%, sehingga dapat disimpulkan bahwa penelitian ini dapat membantu para akseptor KB dalam memilih jenis kontrasepsi yang efektif. Kata Kunci: Akseptor, Algoritma C4.5, Kontrasepsi, Sistem Pakar

  2. PENGEMBANGAN ALAT DESTILATOR BIOETANOL MODEL REFLUK BERTINGKAT DENGAN BAHAN BAKU SINGKONG

    Directory of Open Access Journals (Sweden)

    Rochmad Winarso

    2014-11-01

    Full Text Available ABSTRAK Penyediaan energi di masa depan merupakan permasalahan yang senantiasa menjadi perhatian bagi semua pihak. Seiring dengan meningkatnya pembangunan, kebutuhan akan energi terus meningkat. Disisi lain cadangan minyak bumi sebagai bahan bakar yang paling banyak dipakai saat ini semakin menipis karena sifatnya yang non renewable, oleh karena itu diperlukan upaya untuk mencari bahan bakar alternatif yang renewable sekaligus ramah lingkungan. Bioetanol sebagai salah satu bahan bakar alternatif sampai saat ini belum banyak digunakan. Padahal di Indonesia, banyak sekali sumber daya alam hayati yang dapat digunakan sebagai bahan baku untuk memproduksi bioetanol, salah satunya adalah ubi kayu. Penggunaan bioetanol sebagai bahan bakar didasari oleh sifatnya yang mudah terbakar dan memiliki kalor-bakar netto besar. Tujuan dari penelitian ini adalah mengembangkan alat destilator bioetanol dengan fokus pengembangan pada pengembangan menara refluk dengan sistem bertingkat sehingga diharapkan bisa lebih optimal menghasilkan bioetanol dengan kadar tinggi. Pengembangan alat distilator bioethanol ini dimulai dari proses observasi lapangan yang dilanjutkan dengan studi literatur. Tahapan selajutnya adalah proses perencanaan komponen-komponen dari peralatan tersebut dan dilanjutkan dengan proses pembuatan serta uji coba peralatan. Hasil penelitian ini telah dikembangkan alat destilator bioetanol dengan spesifikasi sebagai berikut: diameter tangki 400 mm, tinggi tangki 500 mm, terbuat dari bahan stainles steel A304 dengan ketebalan 2 mm. Kapasitas tangki yang diijinkan adalah dari volume tabung atau sebesar 40 liter. Dari hasil uji coba pada hasil proses distilasi fermentasi ketela pohon menghasilkan ethanol dengan kadar 92%. Kata kunci: bioetanol, destilator, refluk bertingkat.

  3. Mengungkap Model Pendidikan Hindu Bali Tradisional Aguron-guron

    Directory of Open Access Journals (Sweden)

    Wayan Paramartha

    2017-06-01

    Full Text Available Pendidikan aguron-guron dikembangkan atas dua sub model. Model pertama dikembangkan dengan ideologi sakala ‘realis’ dengan tujuan Parartha ‘kesejahtraan’, yaitu agawe suka nikang rat ‘menjadikan siswa berkarakter dan dapat bekerja untuk kebahagiaan bersama di dunia (baca desa pakraman’. Sedangkan yang kedua adalah ideologi  niskala ‘idealis’ dengan tujuan paramartha, yaitu matutur ikang atma ri jatinya ‘menjadikan siswa sadar akan jati dirinya, bahwa ia sesungguhnya adalah roh’ atau sinar Ilahi. Model pendidikan aguron-guron merupakan kearifan lokal yang menjungjung tinggi nilai-nilai keseimbangan dan harmonisasi. Oleh karena itu terus diperhatikan dan dikembangkan untuk memelihara karakter bangsa, membangun landasan teori pendidikan dan pembelajaran berbasis budaya. Penelitian ini merupakan tahun ke dua, yang bertujuan menghasilkan bahan ajar dan VCD sebagai media pendukung pembelajaran model pendidikan Hindu Bali tradisional aguron-guron serta menguji efektivitas bahan ajar dan media VCD model pendidikan Hindu Bali tradisional aguron-guron tersebut. Penelitian dilaksanakan di Pasraman Seruling Dewata Tabanan dan  Pasraman  Griya  Kekeran  Blahbatuh  Gianyar. Metode pengumpulan data digunakan wawancara, studi kepustakaan, dokumentasi dan angket penilaian bahan ajar dan VCD. Data dianalisis dengan menggunakan analisis deskriptif kuantitatif teknik prosentase dan kualitatif. Hasil uji ahli dan uji coba pengguna perorangan serta uji coba pengguna kelompok kecil terhadap produk yang dikembangkan berupa bahan ajar dan VCD mencakup materi Ilmu Silat Bali Kuno,Tapak Suci, Tattwa dan Nilai-Nilai Pendidikan Agama Hindu  menunjukkan sangat layak dan masuk dalam kategori tidak perlu direvisi

  4. AHP 37: ETHNICITY AND CULTURAL DIVERSITY ON THE NORTHEAST TIBETAN PLATEAU - SANCHUAN'S WEATHER MANAGEMENT RITUALS IN COMPARATIVE CONTEXT

    Directory of Open Access Journals (Sweden)

    Gerald Roche

    2015-06-01

    Full Text Available What is the relationship between ethnic, cultural, and linguistic diversity? This paper is part of a broader project to investigate this question in the context of a region of supposed ethno-cultural rupture – the Sino-Tibetan Frontier. My investigations of ethnicity, culture, and language in this region (Roche 2011, 2014, 2015, Roche and Lcag mo tshe ring 2013, Roche and Stuart 2015 have focused on a population referred to as the Monguor or Tu. My work also aims to contribute to broader trends in the study of Tibet and ethnic minorities in China that look at the complex relations between ethnicity and diversity (Jinba Tenzin 2013, Chao 2012, Merriam 2012, Hayes 2014. My research has been inspired by Barth's (1969 critique of the 'Herderian trinity' of community, culture, and identity (Wimmer 2013. In contrast to the Romantic notion of bounded communities professing a common identity based on shared culture, Barth suggested that the landscape of cultural difference is frequently divided arbitrarily, with ethnic boundaries often placed between culturally similar groups. He therefore advises placing emphasis on boundary marking and maintenance over the 'cultural stuff' contained within ethnic bounds. Within this 'boundary paradigm', "Researchers would no longer study 'the culture' of ethnic group A or B, but rather how the ethnic boundary between A and B was inscribed onto a landscape of continuous cultural transitions" (Wimmer 2013:22-23. ...

  5. Infrared spectroscopy of symbiotic stars and the nature of their cool components

    International Nuclear Information System (INIS)

    Kenyon, S.J.; Gallagher, J.S.

    1983-01-01

    We present low-resolution 2--4 μm spectroscopy of a small sample of symbiotic stars, in an effort to determine if the giant components of these systems fill their Roche Lobes. A [2.35]-[2.2] color index measures the strength of the CO absorption band and provides a useful discriminant of luminosity class among single M-type giants which separates normal giants from supergiants at the same spectral type. Although interpretation of symbiotic spectra is complicated somewhat by their binary nature, our results suggest the late-type components in these systems range from normal red giants to bright asymptotic giants. The possible presence of non-Roche Lobe filling, low-luminosity giants in some symbiotic stars cannot be understood within the framework of existing theories for these interesting objects, and thus may provide important information for understanding mass transfer in binary systems

  6. An International Collaborative Study of Outcome and Prognostic Factors in Patients with Secondary CNS Involvement By Diffuse Large B-Cell Lymphoma

    DEFF Research Database (Denmark)

    El-Galaly, Tarec Christoffer; Cheah, Chan Yoon; Bendtsen, Mette Dahl

    2016-01-01

    that develop SCNS following primary therapy that contains a rituximab-based-regimen as well as the impact of more intensified treatment for SCNS are limited.Aims: The aims of this study were to i) describe the natural history of SCNS in a large cohort of patients treated with immunochemotherapy, and ii......' Hospital, London). Clinico-pathologic and treatment characteristics at the time of SCNS were collected from medical records.Results: In total, 281 patients with SCNS diagnosed between 2001 and 2016 were included. Median age at SCNS was 64 (range 20-93) years and male:female ratio was 1.3. SCNS occurred...... Myers Squib: Research Funding; NanoString Technologies: Research Funding; F Hoffmann-La Roche: Research Funding; Millennium Takeda: Research Funding; Seattle Genetics: Research Funding. Sehn: roche/genentech: Consultancy, Honoraria; amgen: Consultancy, Honoraria; seattle genetics: Consultancy, Honoraria...

  7. Cross-reactivity of amphetamine analogues with Roche Abuscreen radioimmunoassay reagents

    International Nuclear Information System (INIS)

    Cody, J.T.

    1990-01-01

    Cross-reactivity of amphetamine analogues with the Abuscreen amphetamine radioimmunoassay reagents was determined for both the standard and high specificity antibody systems. Compounds tested included 2-methoxyamphetamine, 4-hydroxymethamphetamine, 2,5-dimethoxyamphetamine (DMA), 4-bromo-2,5-dimethoxyamphetamine (DOB), 4-bromo-2,5-dimethoxy-beta-phenethylamine (BDMPEA), 3,4,5-trimethoxyamphetamine (TMA), 3,4-methylenedioxyamphetamine (MDA), N,N-dimethyl-3,4-methylenedioxyamphetamine and N-hydroxy-3,4-methylenedioxyamphetamine (N-OH MDA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyethylamphetamine (MDEA), 2,5-dimethoxy-4-ethylamphetamine, 2,5-dimethoxy-4-methylamphetamine (DOM), and 3,4,5-trimethoxyphenethylamine (mescaline). Blank negative reference material was spiked with 1,000 to 100,000 ng/mL of the amphetamine analogue and used as sample in the assays. MDA was the only analogue that showed cross reactivity equal to or greater than that of amphetamine. None of the other analogue compounds demonstrated a positive result at even the highest concentration; however several showed depressed counts at various concentration levels

  8. Nourrir le sol : la roche comme engrais phosphate | CRDI - Centre ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    15 juil. 2011 ... Les paysans qui pratiquent l'agriculture de subsistance en Afrique subsaharienne n'ont pas d'argent de trop à consacrer à l'achat d'engrais. Pourtant, les engrais sont indispensables pour enrichir le sol tropical, pauvre en phosphate, de cette région. Le phosphore favorise l'enracinement précoce, la santé ...

  9. In the heart of rock; Au coeur de la roche

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-01-01

    This educational document gives a presentation of the Andra underground research laboratory of Bure (Haute-Marne and Meuse, France) devoted to the study of the underground disposal of radioactive wastes. The document is presented in the form of a comics. It describes the geological setting of the laboratory, located in the eastern edge of the Paris basin, the properties of the Callovian-Oxfordian clay layer, the digging of the boreholes and galleries, the mine-by test and its instrumentation, the backfilling and sealing of the galleries and the reversibility of the burial of radioactive waste containers. (J.S.)

  10. Mida roheline tarbija tahab / Catherine Roche ; intervjueerinud Michael S. Hopkins

    Index Scriptorium Estoniae

    Roche, Catherine, 1977-

    2009-01-01

    2008. a. tehtud uuringust, mille abil selgitati välja, mis põhjustel inimesed eelistavad tarbimisel rohelist tootevalikut. Skeemid: Valmisolek maksta rohelise eest rohkem sõltub tootekategooriast ja tajutavatest eelistest; Teadlikkus ja valik

  11. The Report of the Working Group Concerning the Deterrence of and Response to Incidents of Sexual Assault at the U.S. Air Force Academy

    National Research Council Canada - National Science Library

    2003-01-01

    On January 2, 2003, Dr. James G. Roche, the Secretary of the Air Force, received an e-mail directed initially to female cadets, which asserted that there was a significant sexual assault problem at the United States Air Force...

  12. Comparison of two automated assays of BTM (CTX and P1NP) and reference intervals in a Danish population

    DEFF Research Database (Denmark)

    Jørgensen, N R; Møllehave, L T; Hansen, Y B L

    2017-01-01

    the agreement on the two platforms. METHODS: Fasting sera from 2308 individuals (1250 males and 1058 females, age range 24-76 years) participating in the Health2006 study were analyzed for CTX and P1NP using the automated IDS-iSYS analyzer and the automated Cobas e411 analyzer. Participants in anti......-osteoporotic treatment were excluded, while subjects on hormonal contraceptives were included. RESULTS: There was significant disagreement between both the two P1NP assays with a mean difference of -3 μg/L (LoA -19 to 14) (p

  13. Aprendizaje cooperativo. Un recurso indispensable en la formación universitaria

    OpenAIRE

    Cobas Cobiella, María Elena; Montes Rodríguez, María Pilar; Alventosa del Río, Josefina; Guillén Catalán, Raquel; Ortega Giménez, Alfonso; Marí Farinós, Jesús; Muñoz Pérez, David; Martínez Evora, Joan; Panadero de la Cruz, Catalina Edeltrudis; Vega Cardona, Raúl José; Company Alcañiz, Mireia; Rivera Rodón, Gretchen; Ordelín Font, Jorge Luis; Febles Pozo, Nayiber; García Juncos, María Antonia

    2016-01-01

    El Libro “Aprendizaje cooperativo Un recurso indispensable en la formación universitaria”, se enmarca dentro del Proyecto de Innovación docente Finestra Oberta UV_ SFPIE GER 15-314671, bajo la dirección de la Profesora María Elena Cobas Cobiella, del Departamento de Derecho Civil, de la Facultad de Derecho de la Universidad de Valencia. Este libro contiene 19 artículos inéditos de un grupo importante de profesores y especialistas en la temática nacionales e internacionales, así como c...

  14. SAMJ 8919.indd

    African Journals Online (AJOL)

    (i) multifocal or large solitary PRETEXT IV hepatoblastoma .... vitamin K. Early commencement of enteral feeding is also trophic to the ... Pediatr Blood Cancer 2004;42(1):74-83. ... De Baere T, Roche A, Elias D, Lasser P, Lagrange C, Bousson.

  15. Fractionation list: F0000000119 [jPOST repository metadata[Archive

    Lifescience Database Archive (English)

    Full Text Available H7.4) with 154 mM potassium chloride and PhosSTOP (Roche Diagnostics). The homogenates were centrifuge...ants. A part of the homogenate supernatant fractions were further ultra-centrifuged at 105,000 g to obtain c

  16. Correction: General optimization procedure towards the design of a new family of minimal parameter spin-component-scaled double-hybrid density functional theory.

    Science.gov (United States)

    Roch, Loïc M; Baldridge, Kim K

    2018-02-07

    Correction for 'General optimization procedure towards the design of a new family of minimal parameter spin-component-scaled double-hybrid density functional theory' by Loïc M. Roch and Kim K. Baldridge, Phys. Chem. Chem. Phys., 2017, 19, 26191-26200.

  17. 2017-IJBCS-Article-Kouadio Emile Yoboue

    African Journals Online (AJOL)

    hp

    certaines évolutions pédogéochimiques depuis les roches jusqu'aux ... matériaux volcano-sédimentaires dans la zone ... analyse thermique. Aux rayons X ... Les analyses thermiques ATD et. ATG ont ..... et stockage dans les environnements.

  18. Laboratory evaluation of the Coasys® Plus C coagulation analyzer

    NARCIS (Netherlands)

    de Bie, Prim; Schornagel, Willem J.; van den Dool, Erik-Jan; Bakker, Bianca; van Dam, Willem; Heckman, Marion; Ağar, Cetin; Sturk, Auguste; Stroobants, An K.

    2013-01-01

    The Coasys® Plus C (Behnk Elektronik, distributed by Roche Diagnostics) is a coagulation analyzer for small to midsize clinical chemistry laboratories. We performed a laboratory evaluation. After a familiarization period the dead volume, carry-over, capacity, within-assay reproducibility and

  19. Presse triaxiale permettant de quantifier les modes de déformation lors d'essais mécaniques

    OpenAIRE

    Reuschle , Thierry

    2010-01-01

    Presse triaxiale permettant de quantifier les modes de déformation lors d'essais mécaniques : modes de rupture ou d'endommagement, et localisation de la déformation, sur des roches volcaniques, argilites, grès ou carbonates.

  20. Development of a competitive PCR assay for the quantification of ...

    African Journals Online (AJOL)

    ONOS

    2010-01-25

    Jan 25, 2010 ... quantification of total Escherichia coli DNA in water. Omar Kousar Banu, Barnard .... Thereafter the product was ligated into the pGEM®T-easy cloning ... agarose gel using the high pure PCR product purification kit. (Roche® ...

  1. Afican Health Sciences Vol 9 No 3.pmd

    African Journals Online (AJOL)

    Administrator

    Makerere University College of Health Sciences, School of Medicine, Department of Internal Medicine, Gastroenterology. Division. Abstract ... using anti-HCV Enzyme Immuno Assay (Roche Diagnostics). Results: ... patients on antiretroviral therapy may help in the interpretation of the causes of elevated liver enzymes.

  2. Evolution des caractéristiques physico-chimiques de deux zones de frayères à sédimentation contrastée et premiers résultats de survie embryo-larvaire de truite commune (Salmo trutta

    Directory of Open Access Journals (Sweden)

    MASSA F.

    1998-07-01

    Full Text Available L'impact chimique et physique de la sédimentation sur la survie d'oeufs de Salmonidés a été étudié dans la partie amont de deux ruisseaux d'un même bassin à production salmonicole contrastée : le Moulinet qui présente une faible population de truites et la Roche qui est un ruisseau très productif. Les matières en suspension et les sédiments déposés ont été collectés à un pas de temps de 8 ou 15 jours en 1996 et 1997 et les survies embryo-larvaires ont été estimées en parallèle, dans des incubateurs artificiels. Les taux de survie ont été déterminés à l'émergence en 1996 et de la fécondation à l'éclosion, puis de l'éclosion à l'émergence en 1997. Les paramètres chimiques de l'eau interstitielle (oxygène, pH, nitrates, nitrites et ammoniac ont été mesurés au pas de temps de la semaine pendant la période d'incubation 1997 sur des dispositifs enfouis dans le substrat du ruisseau et au moment de l'éclosion dans les incubateurs contenant les oeufs. Les premiers résultats montrent que les taux de survie embryo-larvaires sont nuls en 1996 et faibles en 1997 (0 à 11 %, moyenne : 3,3 % dans le ruisseau du Moulinet alors que parallèlement, la survie est de 20 % sur un incubateur en 1996 et varie de 0 à 23 % en 1997 (moyenne : 7,7 % dans le ruisseau de la Roche. De l'éclosion à l'émergence, les survies sont supérieures à 80 % dans les deux ruisseaux. La sédimentation est contrastée sur les deux sites, plus forte en masse dans le ruisseau de la Roche pendant la période d'incubation mais de granulométrie beaucoup plus grossière que dans le ruisseau du Moulinet (sableuse dominante contre argilolimoneuse. Les teneurs en oxygène dissous mesurées dans le substrat de la Roche restent élevées pendant toute la période d'incubation (teneur minimum de 5 mg/l et sont significativement supérieures à celles mesurées dans le ruisseau du Moulinet pendant la deuxième partie de l'incubation 1997. D'autre part

  3. MODEL PENGENALAN PERMAINAN DALAM PEMBELAJARAN LOMPAT JAUH PADA SISWA KELAS ATAS SEKOLAH DASAR

    Directory of Open Access Journals (Sweden)

    Kurnia Azis Setyawan

    2015-10-01

    Full Text Available Penelitian ini bertujuan untuk menghasilkan model pengenalan pembelajaran lompat jauh pada siswa sekolah dasar (SD kelas atas tahun pelajaran 2013/2014 di Kecamatan Srumbung, Kabupaten Magelang. Model pembelajaran yang dikembangkan diharapkan untuk digunakan guru SD sebagai salah satu bentuk pembelajaran lompat jauh yang baik dan efektif. Penelitian pengembangan ini dilakukan dengan mengadaptasi langkah-langkah penelitian pengembangan sebagai berikut: (1 pengumpulan informasi di lapangan, (2 melakukan analisis terhadap informasi yang telah dikumpul-kan, (3 mengembangkan produk awal (draf model, (4 validasi ahli dan revisi, (5 uji coba lapangan skala kecil dan revisi, (6 uji coba lapangan skala besar dan revisi, dan (7 pembuatan produk final. Uji coba skala kecil dilakukan terhadap siswa kelas 5 SD N Tegalrandu dan SD N Polengan, Kecamatan Srumbung yang berjumlah 31 siswa. Uji coba skala besar dilakukan terhadap siswa kelas 5 SD N Tegalrandu, SD N Polengan, SD N Pucanganom, SD N Pandanretno, SD N Soka 1 yang berjumlah 81 siswa. Instrumen pengumpulan data yang digunakan yaitu; (1 pedoman wawancara, (2 skala nilai, (3 pedoman observasi model pembelajaran, (4 pedoman observasi keefektifan model pembelajaran. Teknik analisis data yang dilakukan yaitu analisis deskriptif kuantitatif dan analisis deskriptif kualitatif. Hasil penelitian ini berupa buku dan video model pengenalan dalam pembelajaran lompat jauh pada SD kelas atas. Berdasarkan penilaian ahli materi cabang olahraga atletik dan guru penjasor-kes, produk model pengenalan dalam pembelajaran lompat jauh pada SD kelas atas, sudah sesuai dan layak untuk digunakan oleh guru penjasorkes dalam mengajarkan materi lompat jauh kepada siswanya dengan nilai rata-rata 98,1%. Kata kunci: pengembangan, permainan, model pengenalan pembelajaran lompat jauh   INTRODUCTION MODELS IN LEARNING GAMES OF LONG JUMP IN UPPER CLASS ELEMENTARY SCHOOL Abstract This study aims to produce introduction models of the

  4. SNP Discovery In Marine Fish Species By 454 Sequencing

    DEFF Research Database (Denmark)

    Panitz, Frank; Nielsen, Rasmus Ory; van Houdt, Jeroen K J

    2011-01-01

    Based on the 454 Next-Generation-Sequencing technology (Roche) a high throughput screening method was devised in order to generate novel genetic markers (SNPs). SNP discovery was performed for three target species of marine fish: hake (Merluccius merluccius), herring (Clupea harengus) and sole...

  5. Reference range determination for whole-blood platelet aggregation using the Multiplate analyzer

    NARCIS (Netherlands)

    Peerschke, Ellinor I. B.; Castellone, Donna D.; Stroobants, A. K.; Francis, John

    2014-01-01

    To develop reference ranges for platelet aggregation using the Multiplate analyzer (Roche Diagnostics, Mannheim, Germany) in blood anticoagulated with sodium citrate (Na-citrate), lithium heparin (Li-heparin), or hirudin. The study was performed at three sites on consented, healthy adults (n = 193)

  6. The American cranberry mitochondrial genome reveals the presence of selenocysteine (tRNA-Sec and SECIS) insertion machinery in land plants

    Science.gov (United States)

    The American cranberry (Vaccinium macrocarpon Ait.) mitochondrial genome was assembled and reconstructed from whole genome 454 Roche GS-FLX and Illumina shotgun sequences. Compared with other Asterids, the reconstruction of the genome revealed an average size mitochondrion (459,678 nt) with comparat...

  7. Methodologies for quantitative systems pharmacology (QSP) models : Design and Estimation

    NARCIS (Netherlands)

    Ribba, B.; Grimm, Hp; Agoram, B.; Davies, M.R.; Gadkar, K.; Niederer, S.; van Riel, N.; Timmis, J.; van der Graaf, Ph.

    2017-01-01

    With the increased interest in the application of quantitative systems pharmacology (QSP) models within medicine research and development, there is an increasing need to formalize model development and verification aspects. In February 2016, a workshop was held at Roche Pharma Research and Early

  8. Methodologies for Quantitative Systems Pharmacology (QSP) Models: Design and Estimation

    NARCIS (Netherlands)

    Ribba, B.; Grimm, H. P.; Agoram, B.; Davies, M. R.; Gadkar, K.; Niederer, S.; van Riel, N.; Timmis, J.; van der Graaf, P. H.

    2017-01-01

    With the increased interest in the application of quantitative systems pharmacology (QSP) models within medicine research and development, there is an increasing need to formalize model development and verification aspects. In February 2016, a workshop was held at Roche Pharma Research and Early

  9. Determination of exon 7 SMN1 deletion in Iranian patients and ...

    Indian Academy of Sciences (India)

    In consideration of these defects and in line with the latter references, we have ... master mix (Roche, Mannheim, Germany), 5 ng of genomic. DNA, and 10 pmol of .... PCR test which can evaluate comprehensively the status of. SMN1 exon 7 ...

  10. Second-generation sequencing of forensic STRs using the Ion Torrent™ HID STR 10-plex and the Ion PGM™

    DEFF Research Database (Denmark)

    Fordyce, Sarah L; Mogensen, Helle Smidt; Børsting, Claus

    2015-01-01

    Second-generation sequencing (SGS) using Roche/454 and Illumina platforms has proved capable of sequencing the majority of the key forensic genetic STR systems. Given that Roche has announced that the 454 platforms will no longer be supported from 2015, focus should now be shifted to competing SGS...... platforms, such as the MiSeq (Illumina) and the Ion Personal Genome Machine (Ion PGM™; Thermo Fisher). There are currently several challenges faced with amplicon-based SGS STR typing in forensic genetics, including current lengths of amplicons for CE-typing and lack of uniform data analysis between......) analysis of sensitivity; (3) typing of mixtures; and (4) typing of biological crime case samples. Full profiles and concordant results between replicate SGS runs and CE-typing were observed for all control samples. Full profiles were seen with DNA input down to 50pg, with the exception of a single locus...

  11. Falsely Elevated Plasma Creatinine Due to an Immunoglobulin M Paraprotein.

    Science.gov (United States)

    McGill, Mitchell R; Vijayan, Anitha; Trulock, Elbert P; Witt, Chad A; Kohler, Giselle D; Scott, Mitchell G

    2016-11-01

    The most common method for measuring plasma creatinine is based on its reaction with picric acid. However, enzymatic methods are becoming more popular due to improved specificity. We present a case of falsely elevated plasma creatinine values obtained by an enzymatic method that turned out to be due to a monoclonal immunoglobulin M (IgM) paraprotein. A 63-year-old woman evaluated for lung transplantation had falsely increased plasma creatinine levels (1.54-1.71mg/dL; corresponding to estimated glomerular filtration rates of 32-36 mL/min/1.73m 2 ) as measured by the Roche Creatinine plus enzymatic assay when compared with the picric acid-based procedure and several other enzymatic methods, which gave plasma creatinine values of 0.7 to 0.8mg/dL. Serum protein electrophoresis revealed an IgM κ light chain paraprotein. Removal of high-molecular-weight (>30kDa) proteins by ultrafiltration reduced the patient's plasma creatinine level by the Roche enzymatic method to 0.7mg/dL. Addition of the patient's immunoglobulin fraction to plasma from other patients with normal plasma creatinine levels resulted in values that were increased by 0.58 to 0.62mg/dL. Furthermore, removal of non-IgM immunoglobulins with protein G-coupled beads did not eliminate the interference from the patient's plasma. Taken together, these studies demonstrate that falsely elevated plasma creatinine values by the Roche enzymatic method can be due to an IgM paraprotein. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  12. Tidal stripping of stars near supermassive black holes

    Directory of Open Access Journals (Sweden)

    Blandford R.

    2012-12-01

    Full Text Available In a binary system composed of a supermassive black hole and a star orbiting the hole in an equatorial, circular orbit, the stellar orbit will shrink due to the action of gravitational radiation, until the star fills its Roche lobe outside the Innermost Stable Circular Orbit (ISCO of the hole or plunges into the hole. In the former case, gas will flow through the inner Lagrange point (L1 to the hole. If this tidal stripping process happens on a time scale faster than the thermal time scale but slower than the dynamical time scale, the entropy as a function of the interior mass is conserved. The star will evolve adiabatically, and, in most cases, will recede from the hole while filling its Roche lobe. We calculate how the stellar equilibrium properties change, which determines how the stellar orbital period and mass-transfer rate change through the “Roche evolution” for various types of stars in the relativistic regime. We envisage that the mass stream eventually hits the accretion disc, where it forms a hot spot orbiting the hole and may ultimately modulate the luminosity with the stellar orbital frequency. The ultimate goal is to probe the mass and spin of the hole and provide a test of general relativity in the strong-field regime from the resultant quasi-periodic signals. The observability of such a modulation is discussed along with a possible interpretation of an intermittent 1 hour period in the X-ray emission of RE J1034+ 396.

  13. Traceability Assessment and Performance Evaluation of Results for Measurement of Abbott Clinical Chemistry Assays on 4 Chemistry Analyzers.

    Science.gov (United States)

    Lim, Jinsook; Song, Kyung Eun; Song, Sang Hoon; Choi, Hyun-Jung; Koo, Sun Hoe; Kwon, Gye Choel

    2016-05-01

    -The traceability of clinical results to internationally recognized and accepted reference materials and reference measurement procedures has become increasingly important. Therefore, the establishment of traceability has become a mandatory requirement for all in vitro diagnostics devices. -To evaluate the traceability of the Abbott Architect c8000 system (Abbott Laboratories, Abbott Park, Illinois), consisting of calibrators and reagents, across 4 different chemistry analyzers, and to evaluate its general performance on the Toshiba 2000FR NEO (Toshiba Medical Systems Corporation, Otawara-shi, Tochigi-ken, Japan). -For assessment of traceability, secondary reference materials were evaluated 5 times, and then bias was calculated. Precision, linearity, and carryover were determined according to the guidelines of the Clinical and Laboratory Standards Institute (Wayne, Pennsylvania). -The biases from 4 different analyzers ranged from -2.33% to 2.70% on the Toshiba 2000FR NEO, -2.33% to 5.12% on the Roche Hitachi 7600 (Roche Diagnostics International, Basel, Switzerland), -0.93% to 2.87% on the Roche Modular, and -2.16% to 2.86% on the Abbott Architect c16000. The total coefficients of variance of all analytes were less than 5%. The coefficients of determination (R(2)) were more than 0.9900. The carryover rate ranged from -0.54% to 0.17%. -Abbott clinical chemistry assays met the performance criteria based on desirable biological variation for precision, bias, and total error. They also showed excellent linearity and carryover. Therefore, these clinical chemistry assays were found to be accurate and reliable and are readily applicable on the various platforms used in this study.

  14. FORMATION OF CENTAURS’ RINGS THROUGH THEIR PARTIAL TIDAL DISRUPTION DURING PLANETARY ENCOUNTERS

    Energy Technology Data Exchange (ETDEWEB)

    Hyodo, Ryuki; Charnoz, Sébastien [Institut de Physique du Globe, F-75005 Paris, France (France); Genda, Hidenori [Earth-Life Science Institute, Tokyo Institute of Technology, Tokyo 152-8550 (Japan); Ohtsuki, Keiji [Department of Planetology, Kobe University, Kobe 657-8501 (Japan)

    2016-09-01

    Centaurs are minor planets orbiting between Jupiter and Neptune that have or had crossing orbits with one or more giant planets. Recent observations and reinterpretation of previous observations have revealed the existence of ring systems around 10199 Chariklo and 2060 Chiron. However, the origin of the ring systems around such a minor planet is still an open question. Here, we propose that the tidal disruption of a differentiated object that experiences a close encounter with a giant planet could naturally form diverse ring–satellite systems around the Centaurs. During the close encounter, the icy mantle of the passing object is preferentially ripped off by the planet's tidal force and the debris is distributed mostly within the Roche limit of the largest remnant body. Assuming the existence of a 20−50 wt% silicate core below the icy mantle, a disk of particles is formed when the objects pass within 0.4–0.8 of the planet's Roche limit with the relative velocity at infinity 3−6 km s{sup −1} and 8 hr initial spin period of the body. The resultant ring mass is 0.1%–10% of the central object's mass. Such particle disks are expected to spread radially, and materials spreading beyond the Roche limit would accrete into satellites. Our numerical results suggest that ring formation would be a natural outcome of such extreme close encounters, and Centaurs can naturally have such ring systems because they cross the orbits of the giant planets.

  15. FORMATION OF CENTAURS’ RINGS THROUGH THEIR PARTIAL TIDAL DISRUPTION DURING PLANETARY ENCOUNTERS

    International Nuclear Information System (INIS)

    Hyodo, Ryuki; Charnoz, Sébastien; Genda, Hidenori; Ohtsuki, Keiji

    2016-01-01

    Centaurs are minor planets orbiting between Jupiter and Neptune that have or had crossing orbits with one or more giant planets. Recent observations and reinterpretation of previous observations have revealed the existence of ring systems around 10199 Chariklo and 2060 Chiron. However, the origin of the ring systems around such a minor planet is still an open question. Here, we propose that the tidal disruption of a differentiated object that experiences a close encounter with a giant planet could naturally form diverse ring–satellite systems around the Centaurs. During the close encounter, the icy mantle of the passing object is preferentially ripped off by the planet's tidal force and the debris is distributed mostly within the Roche limit of the largest remnant body. Assuming the existence of a 20−50 wt% silicate core below the icy mantle, a disk of particles is formed when the objects pass within 0.4–0.8 of the planet's Roche limit with the relative velocity at infinity 3−6 km s"−"1 and 8 hr initial spin period of the body. The resultant ring mass is 0.1%–10% of the central object's mass. Such particle disks are expected to spread radially, and materials spreading beyond the Roche limit would accrete into satellites. Our numerical results suggest that ring formation would be a natural outcome of such extreme close encounters, and Centaurs can naturally have such ring systems because they cross the orbits of the giant planets.

  16. La arquitectura revisionista y orgánica en Estados Unidos

    OpenAIRE

    González Capitel, Antón

    1996-01-01

    5. La arquitectura revisionista y orgánica en Estados Unidos 5. l. Desarrollo y revisión de la arquitectura moderna: Philip Johnson y Paul Rudolph 5. 2. Eclecticismo y organicismo en la obra de Eero Saarinen 5. 3. La obra de Kevin Roche

  17. 76 FR 17927 - Withdrawal of Approval of New Animal Drug Applications; Chorionic Gonadotropin; Cuprimyxin...

    Science.gov (United States)

    2011-03-31

    ... Drug) Labeler Code) Roche Vitamins, Inc., 45 Waterview NADA 093-029 524.520 Blvd., Parsippany, NJ 07054... phosphate/ sulfamethazine). Pegasus Laboratories, Inc., 8809 Ely NADA 102-824 520.1720a Rd., Pensacola, FL 32514. Phenylbutazone Tablets........ (055246) (phenylbutazone) Wendt Laboratories, Inc., 100 Nancy NADA...

  18. UJI COBA PEMULIHAN GIZI BURUK CARA KLINIK GIZI PUSLITBANG GIZI DI POSYANDU

    Directory of Open Access Journals (Sweden)

    Djoko Kartono

    2012-11-01

    Full Text Available Trial The Management of Severe Malnourished Children of Nutrition Clinic Method, The Nutrition Research and Development Centre at Village Level.Background: Managerrent of severe malnutrition recommended by WHO should be in hospital. For family with severe malnourished child, generally poor, hospitalization means spend a lot of money. The alternative method is the out patient management developed by Nutrition Clinic of the Nutrition Research ard Development Centre.Objectives: To study the effectiveneess of management for severe malnourished of Nutrition Clinic method in village level (posyandu by village cadre.Methods: The study was carried out at 4 sub-districts in Bogor and Sukabumi, West Java. Sixty under-five children for group 1 and 60 for group 2 were selected. Three to five posyandu's cadres were selected in each village. Visit schedule to posyandu for group 1 was similar to that Nutrition Clinic while group 2 was every 1 week. Nutrition package for group 1 and 2 was same. Data collection included body measurements, morbiddity and food consumption. Observation to the cadres performance include ownership and he use of guidance book.Results: Seven percent of children aged 6-11 months, 20% aged 12-17 months, 60% aged 18-35 months and 13% aged > 36 months. Around 30% of children had been grven fruit and porridge on the age 1-4 months old. Nutritional status improved variously depended on the nutritional indices. Energy consumption was low but protein consumption had reached the recommended allowance. Compliance to come to posyandu and nutrition package was high.Conclusions: Around 10% of cchildren had changed from under-weight to well-nourished, but most of severe malnourished children remained severe in 3 months. Stunted was over 75% and remained stunted in 3 months. Wasted was 50% and began to decline in 3 months. The average of weight increment in 3 months was 0,6 kg. Cadre could give simple education to mothers using the available guidance book.Recommendations: To use wasted as an indicator in the evaluation of management of severe malnutrition. Active role of health Centre is needed to have maximum effect of the implementation of Nutrition Clinic method at village level.Key words: management, severe malnutrition, nutrition clinic, out-patient, village cadre.

  19. [Low rate of oropharyngeal human papillomavirus infection among women with cervical lesion. Preliminary results from the South-Eastern Hungarian population].

    Science.gov (United States)

    Vanya, Melinda; Jakó, Mária; Terhes, Gabriella; Szakács, László; Kaiser, László; Deák, Judit; Bártfai, György

    2016-01-10

    Although the natural history of cervical and oral human papillomavirus infection has been intensively investigated in the past years, the ability of this virus to infect oral and genital mucosae in the same individual and its potential to co-infect both cervical and oral mucosa are still unclear. The aim of the authors was to assess the presence of oropharyngeal human papillomavirus infection in women with cervical lesions in the South-Eastern Hungarian population. The total of 103 women have been included in the study between March 1, 2013 and January 1, 2015. Brushing was used to collect cells from the oropharyngeal mucosa. Human papillomavirus DNA was detected using polymerase chain reaction, and Amplicor line blot test was used for genotyping. Oropharyngeal human papillomavirus infection was detected in 2 cases (3%). The detected genotypes were 31, 40/61 and 73 in the oropharyngeal region. The results indicate that in women with cervical lesions oropharyngeal human papillomavirus infection rarely occurs.

  20. Distinguishing Plasmodium falciparum treatment failures from re-infections by using polymerase chain reaction genotyping in a holoendemic area in northeastern Tanzania

    DEFF Research Database (Denmark)

    Magesa, S M; Mdira, K Y; Farnert, A

    2001-01-01

    susceptibility to a combination of sulfadoxine/pyrimethamine (Fansidar; F. Hoffmann La Roche, Basel, Switzerland). Blood samples were collected before treatment and on days 7, 14, or 28 post-treatment in 51 asymptomatic children, of which 26 could not clear parasitemia within seven days post-treatment. Among...

  1. False high level in total bilirubin estimation in nonicteric serum

    African Journals Online (AJOL)

    estimation of total bilirubin by DiaSys and Randox reagents along with simultaneous re-estimation by Roche reagents in ... been used mainly due to slightly lower cost in ... MATERIALS AND METHODS ... air-conditioned laboratory overnight. ..... Elevated IgG causing spurious elevation in serum total bilirubin assay. Asia.

  2. Swedish Defence Research Abstracts 82/83-2 (Froe Foersvars Forsknings Referat 82/83-2).

    Science.gov (United States)

    1983-08-01

    alarm (78) Carbon dioxide retention inside motorcycle helmets (79) Vibration and decompression gas bubbles (80) No effects of nootropic drugs on memory... nootropic drugs on memory and psychomotor performance during reduced air pressure (in English) S. Levander and others Report I from the Roche Clinical Unit

  3. 76 FR 17776 - Animal Drugs, Feeds, and Related Products; Withdrawal of Approval of New Animal Drug Applications...

    Science.gov (United States)

    2011-03-31

    ...'s Sponsor (established name of drug) drug labeler code) Roche Vitamins, Inc., 45 Waterview Blvd.... Medicator TS-40 Premix (tylosin phosphate/ sulfamethazine). Pegasus Laboratories, Inc., 8809 Ely Rd., NADA... Laboratories, Inc., 100 Nancy Dr., NADA 108-487, DEC Tabs 520.622a (015579). Belle Plaine, MN 56011...

  4. Middle-to-Upper Palaeolithic site formation processes at the Bordes-Fitte rockshelter (Central France)

    DEFF Research Database (Denmark)

    Aubry, Thierry; Dimuccio, Luca Antonio; Buylaert, Jan-Pieter

    2014-01-01

    . In this article we use the Middle and Early Upper Palaeolithic archaeo-stratigraphic record from the Bordes-Fitte rockshelter (les Roches d'Abilly site, Central France), a Bayesian analysis of the ages obtained by accelerator mass spectrometry radiocarbon on ultrafiltered collagen and by luminescence on quartz...

  5. Neurological Basis and Potential Modification of Emotional Intelligence through Affective/Behavioral Training

    Science.gov (United States)

    2014-12-01

    Dinges, 2007; Punjabi et al., 2003; Van Dongen and Maislin, 2003). Relative to being well rested, prolonged sleep debt may also increase somatic...European Sleep Research Society Sleep credit, grey matter and emotion 533 Punjabi , N. M., Bandeen-Roche, K. and Young, T. Predictors of objective sleep

  6. Environment-Mediated Drug Resistance in Neuroblastoma

    Science.gov (United States)

    2013-10-01

    mice. A. MRI of abdominal cavity of representative mice from NB-Tag and NB- TagxIL6KOat 3 different ages. B. There were no difference between growth...radioimmunoprecipitation assay (RIPA) buffer supplemented with 1 tablet of complete mini-EDTA protease inhibitor cocktail (Roche Diagnostics) or halt

  7. Glutamate Receptor Pathology is Present in the Hippocampus Following Repeated Sub-Lethal Soman Exposure in the Absence of Spatial Memory Deficits

    Science.gov (United States)

    2008-01-01

    CompleteTM protease inhibitor cocktail (Roche Biochemicals; Indianapolis, IN) using a motorized pestle (Caframo; Wairton, ONT) and Tissue Tearer...Morita H, Yanagisawa N, Nakajima T, Shimizu M, Hirabayashi H, Okudera H, et al. Sarin poisoning in Matsumoto, Japan . Lancet 1995;346:290–3. Morris RG

  8. PENGEMBANGAN BUKU AJAR BIOTEKNOLOGI BERBASIS PENELITIAN BIOREMIDIASI LOGAM BERAT KADMIUM UNTUK MAHASISWA S1 BIOLOGI UNIVERSITAS NEGERI MALANG

    Directory of Open Access Journals (Sweden)

    Agung Pambudiono

    2016-06-01

    Tujuan penelitian ini adalah menghasilkan buku ajar berbasis penelitian tentang bioremidiasi logam berat. Penelitian ini mengadaptasi model pengembangan Dick & Carey. Kelayakan buku ajar didasarkan pada hasil uji coba produk oleh tim ahli dan kelompok kecil. Jenis data yang dikumpulkan adalah data kuantitatif dan data kualitatif. Data yang telah terkumpul dianalisis secara deskriptif kuantitatif dan kualitatif. Hasil validasi yang dilakukan oleh ahli materi memberikan nilai persentase kevalidan buku ajar sebesar 91.6%, penilaian dari ahli media sebesar 90.81%. sedangkan penilaian kelompok kecil sebesar 85.56%. Berdasarkan hasil validasi maka buku ajar yang dikembangkan dikategorikan sangat valid dan layak untuk dipergunakan.

  9. Optimasi Jangkauan Jaringan 4G Menggunakan Algoritma Genetika

    Directory of Open Access Journals (Sweden)

    Garsinia Ely Riani

    2016-12-01

    Full Text Available Kemampuan dan jangkauan 4G yang lebih luas daripada teknologi generasi sebelumnya perlu dimaksimalkan. Hal ini mengingat antusiasme pengguna layanan selular dalam menyambut kehadiran teknologi internet cepat ini. Optimasi yang dilakukan memperhatikan luas area, kerapatan pengguna internet dan posisi Base Transceiver Station (BTS. Penelitian ini mengusulkan algoritma genetika sebagai algoritma optimasi yang sering digunakan untuk menyelesaikan berbagai permasalahan kompleks. Optimasi dilakukan untuk memaksimalkan jangkauan 4G  secara efektif dan efisien dari sisi penyedia (provider. Serangkaian uji coba menunjukkan bahwa algoritma genetika mampu memberikan solusi yang cukup baik untuk penentuan posisi BTS dalam permasalahan jangkauan pelanggan.

  10. KOMPETENSI GURU PAUD DALAM MEMBUAT ALAT BERMAIN SAINS DARI LIMBAH

    Directory of Open Access Journals (Sweden)

    Dwi Yulianti

    2013-02-01

    Full Text Available Kegiatan pengabdian masyarakat ini bertujuan meningkatkan kompetensi guru PAUD dalam alat bermain sains (ABS dari barang-barang habis pakai atau limbah. Metode yang diterapkan berupa pelatihan dan workshop yang meliputi kuliah, praktek membuat alat dan peer teaching. ABS yang berhasil dibuat diantaranya tikar warna, pengukuran, menimbang, menakar, magnet, bunyi, pncampuran warna, gravitasi, telepon dari gelas plastik. Setelah kegiatan berlangsung terjadi peningkatan jumlah alat pada masing-masing sekolah. Terjadi pula peningkatan kompetensi guru dalam membuat alat bermain sains. Dari hasil uji coba melalui kegiatan per teaching, hasil belajar kognitif, afektif dan psikomotorik siswa meningkat secara signifikan.

  11. PENGEMBANGAN BUKU AJAR BERBASIS PENELITIAN EVOLUSI DAN FILOGENETIK MOLEKULER UNTUK MATAKULIAH EVOLUSI DI UNIVERSITAS JEMBER

    Directory of Open Access Journals (Sweden)

    Ulin Nuha

    2016-09-01

    Filogenetik molekuler merupakan salah satu kajian yang dipelajari pada matakuliah Evolusi untuk jenjang S1 Pendidikan Biologi. Kajian ini memerlukan bahan ajar yang kontekstual dan tetap mengikuti perkembangan IPTEKS. Kendala yang muncul adalah pengetahuan mahasiswa dalam ranah molekuler masih rendah. Salah satu solusi yang dapat dilakukan adalah dengan menyediakan buku ajar berbasis penelitian denan pendekatan molekuler. Buku ajar dikembangkan berdasarkan model pengembangan ADDIE. Produk divalidasi oleh ahli media, materi, praktisi pendidikan dan diujicobakan pada kelompok kecil. Hasil validasi ahli media, ahli materi, praktisi pendidikan, dan uji coba kelompok kecil secara berturut turut adalah 87,14%, 91,00%, 75,78%, dan 82,22%.

  12. Correction to: Tocilizumab: A Review in Rheumatoid Arthritis.

    Science.gov (United States)

    Scott, Lesley J

    2018-02-01

    The article Tocilizumab: A Review in Rheumatoid Arthritis, written by Lesley J. Scott, was originally published Online First without open access. After publication in volume 77, issue 17, pages 1865-1879 F. Hoffmann-La Roche Ltd requested that the article be Open Choice to make the article an open access publication. Post-publication open access was funded by F. Hoffmann-La Roche Ltd. Further details may be found at http://www.medengine.com/Redeem/68FBF06068F81EA7 . The article is forthwith distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License ( http://creativecommons.org/licenses/by-nc/4.0/ ), which permits any noncommercial use, duplication, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made.

  13. Origin of the use of the word magma in Earth Sciences

    Science.gov (United States)

    Gohau, , G.

    1998-05-01

    The word magma was originally used in pharmacy (1694), and then in chemistry (1773).It took its modern geological significance only during the XIXth century.Although it is generally considered to have been first used in geology in 1879 (Roches eruptives, by Fouque and Michel-Levy), the word was already used by Fournet as early as 1838, and soon by Durocher (1845).Both supported an igneous origin of the granite, and were opposed to the metamorphic origin interpretation which, at that time, was dominant in France.Le mot magma, issu de la pharmacie (1694), et utilise par les chimistes des 1773, ne prend son sens moderne, en geologie, qu'au XIX^e siecle.Quoiqu'on retienne habituellement la date de 1879 (Roches eruptives, par Fouque et Michel-Levy), le terme apparait en fait des 1838, chez Fournet, puis chez Durocher a partir de 1845.Partisans de l'origine ignee du granite, ces deux auteurs s'opposent a la these dominante, en France, de l'origine metamorphique.

  14. PENGEMBANGAN MODUL PEMBELAJARAN KIMIA BERVISI SETS BERORIENTASI CHEMO-ENTREPRENEURSHIP (CEP PADA MATERI LARUTAN ASAM BASA

    Directory of Open Access Journals (Sweden)

    M. Agus Prayitno

    2016-05-01

    Full Text Available Kimia merupakan salah satu mata pelajaran yang berkaitan dengan kehidupan sehari- hari, dari segi lingkungan teknologi, maupun masyarakat. Tujuan penelitian ini adalah menghasilkan modul pembelajaran kimia bervisi SETS berorientasi CEP pada materi larutan asam basa yang layak dan efektif digunakan dalam pembelajaran untuk meningkatkan motivasi belajar, minat wirausaha, dan hasil belajar siswa. Penelitian ini merupakan penelitian pengembangan. Uji coba kelayakan produk pada penelitian ini dilaksanakan di MA Mu’allimin Mu’allimat dengan model penelitian one group pre-test and post-test design dan di MAN Rembang dengan model penelitian pre-test and post-test control group design. Data penelitian diperoleh dengan metode validasi, observasi, dokumentasi, tes, dan skala Likert. Hasil validasi ahli materi, ahli media, dan praktisi menunjukkan bahwa modul pembelajaran kimia bervisi SETS berorientasi CEP sangat layak digunakan dalam pembelajaran kimia dengan skor ratarata pada aspek kegrafikan 95,00, aspek penyajian 95,33, aspek kebahasaan 95,00, dan aspek kegrafikan 94,44. Hasil uji coba modul di MA Mu’allimin Mu’allimat menunjukkan peningkatan motivasi 20%, minat wirausaha 25%, dan hasil belajar siswa 79%. Uji coba modul di MAN Rembang peningkatan motivasi belajar siswa, minat wirausaha, dan hasil belajar siswa kelas eksperimen sebesar 27%, 17% dan 66%, sedangkan peningkatan kelas kontrol secara berturutturut 0,4%, 11%, dan 24%.Chemistryis one of the subjects related to everyday life, in terms of environmental technology, and society. The purpose of this research is to produce visionary chemistry learning modules SETS with CEP oriented on acid-base materials which properly and effectively use in learning to improve learning motivation, entrepreneurial interest, and student learning outcomes. This research is development reaserch. Testing the product viability on the research carried out in MA Mu'allimin Mu'allimat with research model are one

  15. Preliminary study on the coconut crab (Birgus latro rearing in captive pond

    Directory of Open Access Journals (Sweden)

    . Sulistiono

    2009-01-01

    Full Text Available Preliminary study on the coconut crab (Birgus latro rearing was employed in captive pond at Citarate village, Lebak Regency (Banten from May to December 2008.  The rearing activity was done in captive pond sized 5x5x1.3 m3 divided into 22 smaller ponds sized 1x1x1.3 m3 with a hiding hole (constructed by pile stones, supported by two small ponds sized 30x40x40 cm3 for sea and fresh water stocks, respectively.  The coconut crab (N=22 individuals at cement pond I and N=18 individuals at cement pond II were reared in each small ponds (density: 1 individual/pond, feed by a piece of coconut (20-50 gram per individual in each cement pond.  The coconut and the water (sea and fresh water were replaced for 2-3 times per week. Result of the study showed that survival rate was around 82% (ponds I and 83% (ponds II, and mortality was around 18% (ponds I and 18% (ponds II. The coconut crab growth at captive ponds I and II were around 17.5 and 52 gram per month, respectively. Key words:  Preliminary study, rearing, coconut crab (Birgus latro   ABSTRAK Uji coba pemeliharaan kepiting kelapa (Birgus latro dilakukan di kolam penangkaran di Desa Citarate, Kabupaten Lebak (Banten pada Bulan Mei sampai Desember 2008.  Kegiatan pemeliharaan dilakukan pada bak semen berukuran 5x5x1.3 m2 yang terbagi menjadi 22 bak semen lebih kecil yang berukuran 1x1x1.3 m3 dilengkapi dengan tempat persembunyian (berupa tumpukan batu, serta bak kecil sebagai tempat penampungan air laut dan tawar masing-masing berukuran 30x40x40 cm3. Kepiting kelapa (N=22 ekor pada kolam I dan N=18 pada kolam II dimasukkan ke dalam setiap kolam (kepadatan 1 individu/kolam, dan diberikan pakan utama berupa potongan kelapa ukuran sekitar 20-50 gram per individu per kolam.  Penggantian kelapa dan air (tawar dan laut dilakukan 2-3 kali per minggu. Hasil uji coba pemeliharaan kepiting kelapa menunjukkan bahwa tingkat sintasan (survival rate di kolam peliharaan berkisar 82 (Kolam I dan 83% (Kolam II

  16. Pengembangan Modul Pembelajaran Fisika Berbasis Problem Based Learning (PBL pada Materi Gelombang Bunyi untuk Siswa SMA Kelas XII

    Directory of Open Access Journals (Sweden)

    Tri Anita Nur Hasanah

    2017-03-01

    dilakukan dalam tiga tahap yaitu pendefinisian (define, perancangan (design dan pengembangan (develop yang dibatasi sampa uji coba terbatas. Validasi modul oleh 4 validator dan uji coba terbatas  kepada 10 orang siswa. Dari hasil penelitan diperoleh skor segi  materi sebesar 3,59 dengan kriteria layak, segi penyajian sebesar 3,9 dengan kriteria layak, segi bahasa sebesar 3,41 dengan kriteria layak dan hasil uji coba terbatas mendapat rerata skor sebesar  3,6 dengan kriteria sesuai. Dapat disimpulkan bahwa modul pembelajaran fisika berbasis PBL pada materi Gelombang Bunyi untuk siswa SMA kelas XII layak digunakan. Kata Kunci: Modul Pembelajaran Fisika, Problem Based Learning (PBL, Gelombang Bunyi

  17. Dual function of the hemagglutinin H5 fused to chicken CD154 in a ...

    African Journals Online (AJOL)

    Dual function of the hemagglutinin H5 fused to chicken CD154 in a potential strategy of DIVA against avian influenza disease: preliminary study. AG Pose, ES Rodriguez, AC Mendez, JN Gomez, AV Redondo, ER Rodriguez, EMG Ramos, AA Gutierrez, MPR Molto, DG Roche, YS Ugalde, AM Lopez ...

  18. Flow cytometric assay detecting cytotoxicity against human endogenous retrovirus antigens expressed on cultured multiple sclerosis cells

    DEFF Research Database (Denmark)

    Møller-Larsen, A; Brudek, T; Petersen, T

    2013-01-01

    on their surface. Polyclonal antibodies against defined peptides in the Env- and Gag-regions of the HERVs were raised in rabbits and used in antibody-dependent cell-mediated cytotoxicity (ADCC) -assays. Rituximab® (Roche), a chimeric monoclonal antibody against CD20 expressed primarily on B cells, was used...

  19. Massively parallel pyrosequencing of the mitochondrial genome with the 454 methodology in forensic genetics

    DEFF Research Database (Denmark)

    Mikkelsen, Martin; Frank-Hansen, Rune; Hansen, Anders Johannes

    2014-01-01

    RESULTS: of sequencing of whole mitochondrial genome, HV1 and HV2 DNA with the second generation system (SGS) Roche 454 GS Junior were compared with results of Sanger sequencing and SNP typing with SNaPshot single base extension detected with MALDI-TOF and capillary electrophoresis. We investigated...

  20. Prevention of Breast Cancer Cell Transformation by Blockade of the AP-1 Transcription Factor

    Science.gov (United States)

    2001-10-01

    to transfection. pLPCX-TAM67 and control plasmids were transfected with Fugene 6 Regent (Roche) according to manufacture’s protocol. Chloroquine was...breast tu- mor growth with nonisomerizable analogues of similar to those in other reports (27,28). whether increasing or inhibiting AP-1 ac- tamoxifen