WorldWideScience

Sample records for robotic arm operations

  1. Robotic arm

    Science.gov (United States)

    Kwech, Horst

    1989-04-18

    A robotic arm positionable within a nuclear vessel by access through a small diameter opening and having a mounting tube supported within the vessel and mounting a plurality of arm sections for movement lengthwise of the mounting tube as well as for movement out of a window provided in the wall of the mounting tube. An end effector, such as a grinding head or welding element, at an operating end of the robotic arm, can be located and operated within the nuclear vessel through movement derived from six different axes of motion provided by mounting and drive connections between arm sections of the robotic arm. The movements are achieved by operation of remotely-controllable servo motors, all of which are mounted at a control end of the robotic arm to be outside the nuclear vessel.

  2. Robotic arm

    International Nuclear Information System (INIS)

    Kwech, H.

    1989-01-01

    A robotic arm positionable within a nuclear vessel by access through a small diameter opening and having a mounting tube supported within the vessel and mounting a plurality of arm sections for movement lengthwise of the mounting tube as well as for movement out of a window provided in the wall of the mounting tube is disclosed. An end effector, such as a grinding head or welding element, at an operating end of the robotic arm, can be located and operated within the nuclear vessel through movement derived from six different axes of motion provided by mounting and drive connections between arm sections of the robotic arm. The movements are achieved by operation of remotely-controllable servo motors, all of which are mounted at a control end of the robotic arm to be outside the nuclear vessel. 23 figs

  3. An innovative approach for modeling and simulation of an automated industrial robotic arm operated electro-pneumatically

    Science.gov (United States)

    Popa, L.; Popa, V.

    2017-08-01

    The article is focused on modeling an automated industrial robotic arm operated electro-pneumatically and to simulate the robotic arm operation. It is used the graphic language FBD (Function Block Diagram) to program the robotic arm on Zelio Logic automation. The innovative modeling and simulation procedures are considered specific problems regarding the development of a new type of technical products in the field of robotics. Thus, were identified new applications of a Programmable Logic Controller (PLC) as a specialized computer performing control functions with a variety of high levels of complexit.

  4. Evolution of robotic arms.

    Science.gov (United States)

    Moran, Michael E

    2007-01-01

    The foundation of surgical robotics is in the development of the robotic arm. This is a thorough review of the literature on the nature and development of this device with emphasis on surgical applications. We have reviewed the published literature and classified robotic arms by their application: show, industrial application, medical application, etc. There is a definite trend in the manufacture of robotic arms toward more dextrous devices, more degrees-of-freedom, and capabilities beyond the human arm. da Vinci designed the first sophisticated robotic arm in 1495 with four degrees-of-freedom and an analog on-board controller supplying power and programmability. von Kemplen's chess-playing automaton left arm was quite sophisticated. Unimate introduced the first industrial robotic arm in 1961, it has subsequently evolved into the PUMA arm. In 1963 the Rancho arm was designed; Minsky's Tentacle arm appeared in 1968, Scheinman's Stanford arm in 1969, and MIT's Silver arm in 1974. Aird became the first cyborg human with a robotic arm in 1993. In 2000 Miguel Nicolalis redefined possible man-machine capacity in his work on cerebral implantation in owl-monkeys directly interfacing with robotic arms both locally and at a distance. The robotic arm is the end-effector of robotic systems and currently is the hallmark feature of the da Vinci Surgical System making its entrance into surgical application. But, despite the potential advantages of this computer-controlled master-slave system, robotic arms have definite limitations. Ongoing work in robotics has many potential solutions to the drawbacks of current robotic surgical systems.

  5. In-Situ Operations and Planning for the Mars Science Laboratory Robotic Arm: The First 200 Sols

    Science.gov (United States)

    Robinson, M.; Collins, C.; Leger, P.; Carsten, J.; Tompkins, V.; Hartman, F.; Yen, J.

    2013-01-01

    The Robotic Arm (RA) has operated for more than 200 Martian solar days (or sols) since the Mars Science Laboratory rover touched down in Gale Crater on August 5, 2012. During the first seven months on Mars the robotic arm has performed multiple contact science sols including the positioning of the Alpha Particle X-Ray Spectrometer (APXS) and/or Mars Hand Lens Imager (MAHLI) with respect to rocks or loose regolith targets. The RA has supported sample acquisition using both the scoop and drill, sample processing with CHIMRA (Collection and Handling for In- Situ Martian Rock Analysis), and delivery of sample portions to the observation tray, and the SAM (Sample Analysis at Mars) and CHEMIN (Chemistry and Mineralogy) science instruments. This paper describes the planning and execution of robotic arm activities during surface operations, and reviews robotic arm performance results from Mars to date.

  6. Design and analysis on robotic arm for serving hazard container

    Science.gov (United States)

    Razali, Zol Bahri; Kader, Mohamed Mydin M. Abdul; Yi, Khoo Zern; Daud, Mohd Hisam

    2017-09-01

    This paper presents about design, analyses development and fabrication of robotic arm for sorting multi-material. The major problem that urges the initiation of the project is the fact that manufacturing industry is growing at relatively faster rate. Most of the company produce high load robotic arm. Less company creates light weight, and affordable robotic arm. As the result, light weight and affordable robot is developing to cover this issue. Plastic material was used to construct the body of the robotic arm, and an optical sensor was implemented to provide basic recognition of object to be carried. The robotic arm used five servomotors for overall operation; four for its joints, and one for the gripping mechanism. The gripper was designed and fabricated using Perspex due to the light weight and high strength of the material. The operation of the robotic arm was governed by Basic Stamp programming sequence and the device was expected to differentiate material and other objects based on reflective theory, and perform subsequent operations afterwards. The SolidWorks was used to model the detail design of the robotic arm, and to simulate the motion of the device.

  7. Robotic vision system for random bin picking with dual-arm robots

    Directory of Open Access Journals (Sweden)

    Kang Sangseung

    2016-01-01

    Full Text Available Random bin picking is one of the most challenging industrial robotics applications available. It constitutes a complicated interaction between the vision system, robot, and control system. For a packaging operation requiring a pick-and-place task, the robot system utilized should be able to perform certain functions for recognizing the applicable target object from randomized objects in a bin. In this paper, we introduce a robotic vision system for bin picking using industrial dual-arm robots. The proposed system recognizes the best object from randomized target candidates based on stereo vision, and estimates the position and orientation of the object. It then sends the result to the robot control system. The system was developed for use in the packaging process of cell phone accessories using dual-arm robots.

  8. Continuum robot arms inspired by cephalopods

    Science.gov (United States)

    Walker, Ian D.; Dawson, Darren M.; Flash, Tamar; Grasso, Frank W.; Hanlon, Roger T.; Hochner, Binyamin; Kier, William M.; Pagano, Christopher C.; Rahn, Christopher D.; Zhang, Qiming M.

    2005-05-01

    In this paper, we describe our recent results in the development of a new class of soft, continuous backbone ("continuum") robot manipulators. Our work is strongly motivated by the dexterous appendages found in cephalopods, particularly the arms and suckers of octopus, and the arms and tentacles of squid. Our ongoing investigation of these animals reveals interesting and unexpected functional aspects of their structure and behavior. The arrangement and dynamic operation of muscles and connective tissue observed in the arms of a variety of octopus species motivate the underlying design approach for our soft manipulators. These artificial manipulators feature biomimetic actuators, including artificial muscles based on both electro-active polymers (EAP) and pneumatic (McKibben) muscles. They feature a "clean" continuous backbone design, redundant degrees of freedom, and exhibit significant compliance that provides novel operational capacities during environmental interaction and object manipulation. The unusual compliance and redundant degrees of freedom provide strong potential for application to delicate tasks in cluttered and/or unstructured environments. Our aim is to endow these compliant robotic mechanisms with the diverse and dexterous grasping behavior observed in octopuses. To this end, we are conducting fundamental research into the manipulation tactics, sensory biology, and neural control of octopuses. This work in turn leads to novel approaches to motion planning and operator interfaces for the robots. The paper describes the above efforts, along with the results of our development of a series of continuum tentacle-like robots, demonstrating the unique abilities of biologically-inspired design.

  9. High precision detector robot arm system

    Science.gov (United States)

    Shu, Deming; Chu, Yong

    2017-01-31

    A method and high precision robot arm system are provided, for example, for X-ray nanodiffraction with an X-ray nanoprobe. The robot arm system includes duo-vertical-stages and a kinematic linkage system. A two-dimensional (2D) vertical plane ultra-precision robot arm supporting an X-ray detector provides positioning and manipulating of the X-ray detector. A vertical support for the 2D vertical plane robot arm includes spaced apart rails respectively engaging a first bearing structure and a second bearing structure carried by the 2D vertical plane robot arm.

  10. Kinematic equations for resolved-rate control of an industrial robot arm

    Science.gov (United States)

    Barker, L. K.

    1983-01-01

    An operator can use kinematic, resolved-rate equations to dynamically control a robot arm by watching its response to commanded inputs. Known resolved-rate equations for the control of a particular six-degree-of-freedom industrial robot arm and proceeds to simplify the equations for faster computations are derived. Methods for controlling the robot arm in regions which normally cause mathematical singularities in the resolved-rate equations are discussed.

  11. Two-Armed, Mobile, Sensate Research Robot

    Science.gov (United States)

    Engelberger, J. F.; Roberts, W. Nelson; Ryan, David J.; Silverthorne, Andrew

    2004-01-01

    The Anthropomorphic Robotic Testbed (ART) is an experimental prototype of a partly anthropomorphic, humanoid-size, mobile robot. The basic ART design concept provides for a combination of two-armed coordination, tactility, stereoscopic vision, mobility with navigation and avoidance of obstacles, and natural-language communication, so that the ART could emulate humans in many activities. The ART could be developed into a variety of highly capable robotic assistants for general or specific applications. There is especially great potential for the development of ART-based robots as substitutes for live-in health-care aides for home-bound persons who are aged, infirm, or physically handicapped; these robots could greatly reduce the cost of home health care and extend the term of independent living. The ART is a fully autonomous and untethered system. It includes a mobile base on which is mounted an extensible torso topped by a head, shoulders, and two arms. All subsystems of the ART are powered by a rechargeable, removable battery pack. The mobile base is a differentially- driven, nonholonomic vehicle capable of a speed >1 m/s and can handle a payload >100 kg. The base can be controlled manually, in forward/backward and/or simultaneous rotational motion, by use of a joystick. Alternatively, the motion of the base can be controlled autonomously by an onboard navigational computer. By retraction or extension of the torso, the head height of the ART can be adjusted from 5 ft (1.5 m) to 6 1/2 ft (2 m), so that the arms can reach either the floor or high shelves, or some ceilings. The arms are symmetrical. Each arm (including the wrist) has a total of six rotary axes like those of the human shoulder, elbow, and wrist joints. The arms are actuated by electric motors in combination with brakes and gas-spring assists on the shoulder and elbow joints. The arms are operated under closed-loop digital control. A receptacle for an end effector is mounted on the tip of the wrist and

  12. INDUSTRIAL ROBOT ARM SIMULATION SOFTWARE DEVELOPMENT USING JAVA-3D AND MATLAB SIMULINK PROGRAMMING LANGUAGE

    OpenAIRE

    Wirabhuana, Arya

    2011-01-01

    Robot Arms Simulation Software development using Structured Programming Languages, Third Party Language, and Artificial Intelligence Programming Language are the common techniques in simulating robot arms movement. Those three techniques are having its strengths and weaknesses depend on several constraints such as robot type, degree of operation complexity to be simulated, operator skills, and also computer capability. This paper will discuss on Robot Arms Simulation Software (RSS) developmen...

  13. Endoscopic endonasal transsphenoidal surgery using the iArmS operation support robot: initial experience in 43 patients.

    Science.gov (United States)

    Ogiwara, Toshihiro; Goto, Tetsuya; Nagm, Alhusain; Hongo, Kazuhiro

    2017-05-01

    Objective The intelligent arm-support system, iArmS, which follows the surgeon's arm and automatically fixes it at an adequate position, was developed as an operation support robot. iArmS was designed to support the surgeon's forearm to prevent hand trembling and to alleviate fatigue during surgery with a microscope. In this study, the authors report on application of this robotic device to endoscopic endonasal transsphenoidal surgery (ETSS) and evaluate their initial experiences. Methods The study population consisted of 43 patients: 29 with pituitary adenoma, 3 with meningioma, 3 with Rathke's cleft cyst, 2 with craniopharyngioma, 2 with chordoma, and 4 with other conditions. All patients underwent surgery via the endonasal transsphenoidal approach using a rigid endoscope. During the nasal and sphenoid phases, iArmS was used to support the surgeon's nondominant arm, which held the endoscope. The details of the iArmS and clinical results were collected. Results iArmS followed the surgeon's arm movement automatically. It reduced the surgeon's fatigue and stabilized the surgeon's hand during ETSS. Shaking of the video image decreased due to the steadying of the surgeon's scope-holding hand with iArmS. There were no complications related to use of the device. Conclusions The intelligent armrest, iArmS, seems to be safe and effective during ETSS. iArmS is helpful for improving the precision and safety not only for microscopic neurosurgery, but also for ETSS. Ongoing advances in robotics ensure the continued evolution of neurosurgery.

  14. Special Gripper for a Robotic Arm

    Directory of Open Access Journals (Sweden)

    Miguel Angel SELLES

    2012-12-01

    Full Text Available New structures for gripping objects in robotic manipulation processes are oriented to the new arrangement of mechanical structures using new materials and processing technologies and innovative procedures for the implementation of contact gripping element links to an object with a high degree of adaptively of applications together with the ability to alter the structure of grip and limiting the intensity of the contact stiffness variation of snap elements custody and pliability. The application of elastomeric materials and surface finishes is important. This paper presents both a new gripper design for robot arms but also the search of the selected materials to make an experimental evaluation of technical parameters that are used to assess their application potential and suitability for the targeted applications. Also the results and conclusions for gripper testing in manipulation operations with two different robot arms are presented.

  15. Robot-Arm Dynamic Control by Computer

    Science.gov (United States)

    Bejczy, Antal K.; Tarn, Tzyh J.; Chen, Yilong J.

    1987-01-01

    Feedforward and feedback schemes linearize responses to control inputs. Method for control of robot arm based on computed nonlinear feedback and state tranformations to linearize system and decouple robot end-effector motions along each of cartesian axes augmented with optimal scheme for correction of errors in workspace. Major new feature of control method is: optimal error-correction loop directly operates on task level and not on joint-servocontrol level.

  16. The MVACS Robotic Arm Camera

    Science.gov (United States)

    Keller, H. U.; Hartwig, H.; Kramm, R.; Koschny, D.; Markiewicz, W. J.; Thomas, N.; Fernades, M.; Smith, P. H.; Reynolds, R.; Lemmon, M. T.; Weinberg, J.; Marcialis, R.; Tanner, R.; Boss, B. J.; Oquest, C.; Paige, D. A.

    2001-08-01

    The Robotic Arm Camera (RAC) is one of the key instruments newly developed for the Mars Volatiles and Climate Surveyor payload of the Mars Polar Lander. This lightweight instrument employs a front lens with variable focus range and takes images at distances from 11 mm (image scale 1:1) to infinity. Color images with a resolution of better than 50 μm can be obtained to characterize the Martian soil. Spectral information of nearby objects is retrieved through illumination with blue, green, and red lamp sets. The design and performance of the camera are described in relation to the science objectives and operation. The RAC uses the same CCD detector array as the Surface Stereo Imager and shares the readout electronics with this camera. The RAC is mounted at the wrist of the Robotic Arm and can characterize the contents of the scoop, the samples of soil fed to the Thermal Evolved Gas Analyzer, the Martian surface in the vicinity of the lander, and the interior of trenches dug out by the Robotic Arm. It can also be used to take panoramic images and to retrieve stereo information with an effective baseline surpassing that of the Surface Stereo Imager by about a factor of 3.

  17. Translational control of a graphically simulated robot arm by kinematic rate equations that overcome elbow joint singularity

    Science.gov (United States)

    Barker, L. K.; Houck, J. A.; Carzoo, S. W.

    1984-01-01

    An operator commands a robot hand to move in a certain direction relative to its own axis system by specifying a velocity in that direction. This velocity command is then resolved into individual joint rotational velocities in the robot arm to effect the motion. However, the usual resolved-rate equations become singular when the robot arm is straightened. To overcome this elbow joint singularity, equations were developed which allow continued translational control of the robot hand even though the robot arm is (or is nearly) fully extended. A feature of the equations near full arm extension is that an operator simply extends and retracts the robot arm to reverse the direction of the elbow bend (difficult maneuver for the usual resolved-rate equations). Results show successful movement of a graphically simulated robot arm.

  18. Augmented reality user interface for mobile ground robots with manipulator arms

    Science.gov (United States)

    Vozar, Steven; Tilbury, Dawn M.

    2011-01-01

    Augmented Reality (AR) is a technology in which real-world visual data is combined with an overlay of computer graphics, enhancing the original feed. AR is an attractive tool for teleoperated UGV UIs as it can improve communication between robots and users via an intuitive spatial and visual dialogue, thereby increasing operator situational awareness. The successful operation of UGVs often relies upon both chassis navigation and manipulator arm control, and since existing literature usually focuses on one task or the other, there is a gap in mobile robot UIs that take advantage of AR for both applications. This work describes the development and analysis of an AR UI system for a UGV with an attached manipulator arm. The system supplements a video feed shown to an operator with information about geometric relationships within the robot task space to improve the operator's situational awareness. Previous studies on AR systems and preliminary analyses indicate that such an implementation of AR for a mobile robot with a manipulator arm is anticipated to improve operator performance. A full user-study can determine if this hypothesis is supported by performing an analysis of variance on common test metrics associated with UGV teleoperation.

  19. Monitoring and Controlling an Underwater Robotic Arm

    Science.gov (United States)

    Haas, John; Todd, Brian Keith; Woodcock, Larry; Robinson, Fred M.

    2009-01-01

    The SSRMS Module 1 software is part of a system for monitoring an adaptive, closed-loop control of the motions of a robotic arm in NASA s Neutral Buoyancy Laboratory, where buoyancy in a pool of water is used to simulate the weightlessness of outer space. This software is so named because the robot arm is a replica of the Space Shuttle Remote Manipulator System (SSRMS). This software is distributed, running on remote joint processors (RJPs), each of which is mounted in a hydraulic actuator comprising the joint of the robotic arm and communicating with a poolside processor denoted the Direct Control Rack (DCR). Each RJP executes the feedback joint-motion control algorithm for its joint and communicates with the DCR. The DCR receives joint-angular-velocity commands either locally from an operator or remotely from computers that simulate the flight like SSRMS and perform coordinated motion calculations based on hand-controller inputs. The received commands are checked for validity before they are transmitted to the RJPs. The DCR software generates a display of the statuses of the RJPs for the DCR operator and can shut down the hydraulic pump when excessive joint-angle error or failure of a RJP is detected.

  20. Robots testing robots: ALAN-Arm, a humanoid arm for the testing of robotic rehabilitation systems.

    Science.gov (United States)

    Brookes, Jack; Kuznecovs, Maksims; Kanakis, Menelaos; Grigals, Arturs; Narvidas, Mazvydas; Gallagher, Justin; Levesley, Martin

    2017-07-01

    Robotics is increasing in popularity as a method of providing rich, personalized and cost-effective physiotherapy to individuals with some degree of upper limb paralysis, such as those who have suffered a stroke. These robotic rehabilitation systems are often high powered, and exoskeletal systems can attach to the person in a restrictive manner. Therefore, ensuring the mechanical safety of these devices before they come in contact with individuals is a priority. Additionally, rehabilitation systems may use novel sensor systems to measure current arm position. Used to capture and assess patient movements, these first need to be verified for accuracy by an external system. We present the ALAN-Arm, a humanoid robotic arm designed to be used for both accuracy benchmarking and safety testing of robotic rehabilitation systems. The system can be attached to a rehabilitation device and then replay generated or human movement trajectories, as well as autonomously play rehabilitation games or activities. Tests of the ALAN-Arm indicated it could recreate the path of a generated slow movement path with a maximum error of 14.2mm (mean = 5.8mm) and perform cyclic movements up to 0.6Hz with low gain (<1.5dB). Replaying human data trajectories showed the ability to largely preserve human movement characteristics with slightly higher path length and lower normalised jerk.

  1. Kinematics/statics analysis of a novel serial-parallel robotic arm with hand

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Yi; Dai, Zhuohong; Ye, Nijia; Wang, Peng [Yanshan University, Hebei (China)

    2015-10-15

    A robotic arm with fingered hand generally has multi-functions to complete various complicated operations. A novel serial-parallel robotic arm with a hand is proposed and its kinematics and statics are studied systematically. A 3D prototype of the serial-parallel robotic arm with a hand is constructed and analyzed by simulation. The serial-parallel robotic arm with a hand is composed of an upper 3RPS parallel manipulator, a lower 3SPR parallel manipulator and a hand with three finger mechanisms. Its kinematics formulae for solving the displacement, velocity, acceleration of are derived. Its statics formula for solving the active/constrained forces is derived. Its reachable workspace and orientation workspace are constructed and analyzed. Finally, an analytic example is given for solving the kinematics and statics of the serial-parallel robotic arm with a hand and the analytic solutions are verified by a simulation mechanism.

  2. Kinematics/statics analysis of a novel serial-parallel robotic arm with hand

    International Nuclear Information System (INIS)

    Lu, Yi; Dai, Zhuohong; Ye, Nijia; Wang, Peng

    2015-01-01

    A robotic arm with fingered hand generally has multi-functions to complete various complicated operations. A novel serial-parallel robotic arm with a hand is proposed and its kinematics and statics are studied systematically. A 3D prototype of the serial-parallel robotic arm with a hand is constructed and analyzed by simulation. The serial-parallel robotic arm with a hand is composed of an upper 3RPS parallel manipulator, a lower 3SPR parallel manipulator and a hand with three finger mechanisms. Its kinematics formulae for solving the displacement, velocity, acceleration of are derived. Its statics formula for solving the active/constrained forces is derived. Its reachable workspace and orientation workspace are constructed and analyzed. Finally, an analytic example is given for solving the kinematics and statics of the serial-parallel robotic arm with a hand and the analytic solutions are verified by a simulation mechanism.

  3. Reprogramming the articulated robotic arm for glass handling by using Arduino microcontroller

    Science.gov (United States)

    Razali, Zol Bahri; Kader, Mohamed Mydin M. Abdul; Kadir, Mohd Asmadi Akmal; Daud, Mohd Hisam

    2017-09-01

    The application of articulated robotic arm in industries is raised due to the expansion of using robot to replace human task, especially for the harmful tasks. However a few problems happen with the program use to schedule the arm, Thus the purpose of this project is to design, fabricate and integrate an articulated robotic arm by using Arduino microcontroller for handling glass sorting system. This project was designed to segregate glass and non-glass waste which would be pioneer step for recycling. This robotic arm has four servo motors to operate as a whole; three for the body and one for holding mechanism. This intelligent system is controlled by Arduino microcontroller and build with optical sensor to provide the distinguish objects that will be handled. Solidworks model was used to produce the detail design of the robotic arm and make the mechanical properties analysis by using a CAD software.

  4. Picking Robot Arm Trajectory Planning Method

    Directory of Open Access Journals (Sweden)

    Zhang Zhiyong

    2014-01-01

    Full Text Available The picking robot arm is scheduled to complete picking tasks in the working space, to overcome the shaking vibration to improve the picking stability, its movement should follow specific consistence trajectory points. Usually we should give definite multiple feature picking points, map their inverse kinematics to the joint space, establish motion equation for the corresponding point in the joint space, then follow these equations motion for the interpolation on the joint so that we can meet the movement requirements. Trajectory planning is decisive significance for accuracy and stability of controlling robot arm. The key issue that picking arm complete picking task will be come true by trajectory planning, namely, robot arm track the desired trajectory. which based on kinematics and statics picking analysis in a joint space according to the requirements of picking tasks, and obtain the position and orientation for picking robot arm, study and calculate the theory of trajectory parameters timely.

  5. Exact positioning of the robotic arm end effector

    Science.gov (United States)

    Korepanov, Valery; Dudkin, Fedir

    2016-07-01

    Orbital service becomes a new challenge of space exploration. The necessity to introduce it is connected first of all with an attractive opportunity to prolong the exploitation terms of expensive commercial satellites by, e.g., refilling of fuel or changing batteries. Other application area is a fight with permanently increasing amount of space litter - defunct satellites, burnt-out rocket stages, discarded trash and other debris. Now more than few tens of thousands orbiting objects larger than 5-10 cm (or about 1 million junks larger than 1 cm) are a huge problem for crucial and costly satellites and manned vehicles. For example, in 2014 the International Space Station had to change three times its orbit to avoid collision with space debris. So the development of the concepts and actions related to removal of space debris or non-operational satellites with use of robotic arm of a servicing satellite is very actual. Such a technology is also applicable for unmanned exploratory missions in solar system, for example for collecting a variety of samples from a celestial body surface. Naturally, the robotic arm movements should be controlled with great accuracy at influence of its non-rigidity, thermal and other factors. In these circumstances often the position of the arm end effector has to be controlled with high accuracy. The possibility of coordinate determination for the robotic arm end effector with use of a low frequency active electromagnetic system has been considered in the presented report. The proposed design of such a system consists of a small magnetic dipole source, which is mounted inside of the arm end effector and two or three 3-component magnetic field sensors mounted on a servicing satellite body. The data from this set of 3-component magnetic field sensors, which are fixed relatively to the satellite body, allows use of the mathematical approach for determination of position and orientation of the magnetic dipole source. The theoretical

  6. Investigating Astromaterials Curation Applications for Dexterous Robotic Arms

    Science.gov (United States)

    Snead, C. J.; Jang, J. H.; Cowden, T. R.; McCubbin, F. M.

    2018-01-01

    The Astromaterials Acquisition and Curation office at NASA Johnson Space Center is currently investigating tools and methods that will enable the curation of future astromaterials collections. Size and temperature constraints for astromaterials to be collected by current and future proposed missions will require the development of new robotic sample and tool handling capabilities. NASA Curation has investigated the application of robot arms in the past, and robotic 3-axis micromanipulators are currently in use for small particle curation in the Stardust and Cosmic Dust laboratories. While 3-axis micromanipulators have been extremely successful for activities involving the transfer of isolated particles in the 5-20 micron range (e.g. from microscope slide to epoxy bullet tip, beryllium SEM disk), their limited ranges of motion and lack of yaw, pitch, and roll degrees of freedom restrict their utility in other applications. For instance, curators removing particles from cosmic dust collectors by hand often employ scooping and rotating motions to successfully free trapped particles from the silicone oil coatings. Similar scooping and rotating motions are also employed when isolating a specific particle of interest from an aliquot of crushed meteorite. While cosmic dust curators have been remarkably successful with these kinds of particle manipulations using handheld tools, operator fatigue limits the number of particles that can be removed during a given extraction session. The challenges for curation of small particles will be exacerbated by mission requirements that samples be processed in N2 sample cabinets (i.e. gloveboxes). We have been investigating the use of compact robot arms to facilitate sample handling within gloveboxes. Six-axis robot arms potentially have applications beyond small particle manipulation. For instance, future sample return missions may involve biologically sensitive astromaterials that can be easily compromised by physical interaction with

  7. The Phoenix Mars Lander Robotic Arm

    Science.gov (United States)

    Bonitz, Robert; Shiraishi, Lori; Robinson, Matthew; Carsten, Joseph; Volpe, Richard; Trebi-Ollennu, Ashitey; Arvidson, Raymond E.; Chu, P. C.; Wilson, J. J.; Davis, K. R.

    2009-01-01

    The Phoenix Mars Lander Robotic Arm (RA) has operated for over 150 sols since the Lander touched down on the north polar region of Mars on May 25, 2008. During its mission it has dug numerous trenches in the Martian regolith, acquired samples of Martian dry and icy soil, and delivered them to the Thermal Evolved Gas Analyzer (TEGA) and the Microscopy, Electrochemistry, and Conductivity Analyzer (MECA). The RA inserted the Thermal and Electrical Conductivity Probe (TECP) into the Martian regolith and positioned it at various heights above the surface for relative humidity measurements. The RA was used to point the Robotic Arm Camera to take images of the surface, trenches, samples within the scoop, and other objects of scientific interest within its workspace. Data from the RA sensors during trenching, scraping, and trench cave-in experiments have been used to infer mechanical properties of the Martian soil. This paper describes the design and operations of the RA as a critical component of the Phoenix Mars Lander necessary to achieve the scientific goals of the mission.

  8. Design of a biomimetic robotic octopus arm.

    Science.gov (United States)

    Laschi, C; Mazzolai, B; Mattoli, V; Cianchetti, M; Dario, P

    2009-03-01

    This paper reports the rationale and design of a robotic arm, as inspired by an octopus arm. The octopus arm shows peculiar features, such as the ability to bend in all directions, to produce fast elongations, and to vary its stiffness. The octopus achieves these unique motor skills, thanks to its peculiar muscular structure, named muscular hydrostat. Different muscles arranged on orthogonal planes generate an antagonistic action on each other in the muscular hydrostat, which does not change its volume during muscle contractions, and allow bending and elongation of the arm and stiffness variation. By drawing inspiration from natural skills of octopus, and by analysing the geometry and mechanics of the muscular structure of its arm, we propose the design of a robot arm consisting of an artificial muscular hydrostat structure, which is completely soft and compliant, but also able to stiffen. In this paper, we discuss the design criteria of the robotic arm and how this design and the special arrangement of its muscular structure may bring the building of a robotic arm into being, by showing the results obtained by mathematical models and prototypical mock-ups.

  9. Design of a biomimetic robotic octopus arm

    Energy Technology Data Exchange (ETDEWEB)

    Laschi, C; Cianchetti, M [Advanced Robotics Technology and Systems Laboratory, Scuola Superiore Sant' Anna, Pisa (Italy); Mazzolai, B; Dario, P [Italian Institute of Technology, Genova (Italy); Mattoli, V [Centre of Research in Microengineering Laboratory, Scuola Superiore Sant' Anna, Pisa (Italy)], E-mail: cecilia.laschi@sssup.it

    2009-03-01

    This paper reports the rationale and design of a robotic arm, as inspired by an octopus arm. The octopus arm shows peculiar features, such as the ability to bend in all directions, to produce fast elongations, and to vary its stiffness. The octopus achieves these unique motor skills, thanks to its peculiar muscular structure, named muscular hydrostat. Different muscles arranged on orthogonal planes generate an antagonistic action on each other in the muscular hydrostat, which does not change its volume during muscle contractions, and allow bending and elongation of the arm and stiffness variation. By drawing inspiration from natural skills of octopus, and by analysing the geometry and mechanics of the muscular structure of its arm, we propose the design of a robot arm consisting of an artificial muscular hydrostat structure, which is completely soft and compliant, but also able to stiffen. In this paper, we discuss the design criteria of the robotic arm and how this design and the special arrangement of its muscular structure may bring the building of a robotic arm into being, by showing the results obtained by mathematical models and prototypical mock-ups.

  10. Design of a biomimetic robotic octopus arm

    International Nuclear Information System (INIS)

    Laschi, C; Cianchetti, M; Mazzolai, B; Dario, P; Mattoli, V

    2009-01-01

    This paper reports the rationale and design of a robotic arm, as inspired by an octopus arm. The octopus arm shows peculiar features, such as the ability to bend in all directions, to produce fast elongations, and to vary its stiffness. The octopus achieves these unique motor skills, thanks to its peculiar muscular structure, named muscular hydrostat. Different muscles arranged on orthogonal planes generate an antagonistic action on each other in the muscular hydrostat, which does not change its volume during muscle contractions, and allow bending and elongation of the arm and stiffness variation. By drawing inspiration from natural skills of octopus, and by analysing the geometry and mechanics of the muscular structure of its arm, we propose the design of a robot arm consisting of an artificial muscular hydrostat structure, which is completely soft and compliant, but also able to stiffen. In this paper, we discuss the design criteria of the robotic arm and how this design and the special arrangement of its muscular structure may bring the building of a robotic arm into being, by showing the results obtained by mathematical models and prototypical mock-ups

  11. Neurosurgical robotic arm drilling navigation system.

    Science.gov (United States)

    Lin, Chung-Chih; Lin, Hsin-Cheng; Lee, Wen-Yo; Lee, Shih-Tseng; Wu, Chieh-Tsai

    2017-09-01

    The aim of this work was to develop a neurosurgical robotic arm drilling navigation system that provides assistance throughout the complete bone drilling process. The system comprised neurosurgical robotic arm navigation combining robotic and surgical navigation, 3D medical imaging based surgical planning that could identify lesion location and plan the surgical path on 3D images, and automatic bone drilling control that would stop drilling when the bone was to be drilled-through. Three kinds of experiment were designed. The average positioning error deduced from 3D images of the robotic arm was 0.502 ± 0.069 mm. The correlation between automatically and manually planned paths was 0.975. The average distance error between automatically planned paths and risky zones was 0.279 ± 0.401 mm. The drilling auto-stopping algorithm had 0.00% unstopped cases (26.32% in control group 1) and 70.53% non-drilled-through cases (8.42% and 4.21% in control groups 1 and 2). The system may be useful for neurosurgical robotic arm drilling navigation. Copyright © 2016 John Wiley & Sons, Ltd.

  12. JACoW A dual arms robotic platform control for navigation, inspection and telemanipulation

    CERN Document Server

    Di Castro, Mario; Ferre, Manuel; Gilardoni, Simone; Losito, Roberto; Lunghi, Giacomo; Masi, Alessandro

    2018-01-01

    High intensity hadron colliders and fixed target experiments require an increasing amount of robotic tele-manipulation to prevent excessive exposure of maintenance personnel to the radioactive environment. Telemanipulation tasks are often required on old radioactive devices not conceived to be maintained and handled using standard industrial robotic solutions. Robotic platforms with a level of dexterity that often require the use of two robotic arms with a minimum of six degrees of freedom are instead needed for these purposes. In this paper, the control of a novel robust robotic platform able to host and to carry safely a dual robotic arm system is presented. The control of the arms is fully integrated with the vehicle control in order to guarantee simplicity to the operators during the realization of the robotic tasks. A novel high-level control architecture for the new robot is shown, as well as a novel low level safety layer for anti-collision and recovery scenarios. Preliminary results of the system comm...

  13. Stress analysis for robot arm version 2

    International Nuclear Information System (INIS)

    Anwar Abdul Rahman; Fikri, A.; Salleh, M. S.; Mohd Arif Hamzah; Azraf Azman; Rosli Darmawan; Mohd Rizal Mamat

    2010-01-01

    The design of a robot needs to be analyzed to ensure the specification and requirement by the user is full filled. Therefore, stress analysis has been performed on the robot arm version 2 after its complete fabrication. This paper discusses the result of the analysis and proposed measures to improve the future design of robot arm. (author)

  14. Octopus-inspired multi-arm robotic swimming.

    Science.gov (United States)

    Sfakiotakis, M; Kazakidi, A; Tsakiris, D P

    2015-05-13

    The outstanding locomotor and manipulation characteristics of the octopus have recently inspired the development, by our group, of multi-functional robotic swimmers, featuring both manipulation and locomotion capabilities, which could be of significant engineering interest in underwater applications. During its little-studied arm-swimming behavior, as opposed to the better known jetting via the siphon, the animal appears to generate considerable propulsive thrust and rapid acceleration, predominantly employing movements of its arms. In this work, we capture the fundamental characteristics of the corresponding complex pattern of arm motion by a sculling profile, involving a fast power stroke and a slow recovery stroke. We investigate the propulsive capabilities of a multi-arm robotic system under various swimming gaits, namely patterns of arm coordination, which achieve the generation of forward, as well as backward, propulsion and turning. A lumped-element model of the robotic swimmer, which considers arm compliance and the interaction with the aquatic environment, was used to study the characteristics of these gaits, the effect of various kinematic parameters on propulsion, and the generation of complex trajectories. This investigation focuses on relatively high-stiffness arms. Experiments employing a compliant-body robotic prototype swimmer with eight compliant arms, all made of polyurethane, inside a water tank, successfully demonstrated this novel mode of underwater propulsion. Speeds of up to 0.26 body lengths per second (approximately 100 mm s(-1)), and propulsive forces of up to 3.5 N were achieved, with a non-dimensional cost of transport of 1.42 with all eight arms and of 0.9 with only two active arms. The experiments confirmed the computational results and verified the multi-arm maneuverability and simultaneous object grasping capability of such systems.

  15. Industrial dual arm robot manipulator for precise assembly of mechanical parts

    Science.gov (United States)

    Park, Chanhun; Kim, Doohyung; Park, Kyoungtaik; Choi, Youngjin

    2007-12-01

    A new structure of dual arm robot manipulator which consists of two industrial 6-DOF arms and one 2-DOF Torso is introduced. Each industrial 6-DOF arm is able to be used as a stand-alone industrial 6-DOF robot manipulator and as a part of dual arm manipulator at the same time. These structures help the robot maker which is willing to succeed in the emerging dual arm robot market in order to have high competition for the current industrial robot market at same time. Self-collision detection algorithm for multi-arm robot and kinematics algorithms for the developed dual arm robot manipulator which are implemented in our controller are introduced.

  16. Multi-arm multilateral haptics-based immersive tele-robotic system (HITS) for improvised explosive device disposal

    Science.gov (United States)

    Erickson, David; Lacheray, Hervé; Lai, Gilbert; Haddadi, Amir

    2014-06-01

    This paper presents the latest advancements of the Haptics-based Immersive Tele-robotic System (HITS) project, a next generation Improvised Explosive Device (IED) disposal (IEDD) robotic interface containing an immersive telepresence environment for a remotely-controlled three-articulated-robotic-arm system. While the haptic feedback enhances the operator's perception of the remote environment, a third teleoperated dexterous arm, equipped with multiple vision sensors and cameras, provides stereo vision with proper visual cues, and a 3D photo-realistic model of the potential IED. This decentralized system combines various capabilities including stable and scaled motion, singularity avoidance, cross-coupled hybrid control, active collision detection and avoidance, compliance control and constrained motion to provide a safe and intuitive control environment for the operators. Experimental results and validation of the current system are presented through various essential IEDD tasks. This project demonstrates that a two-armed anthropomorphic Explosive Ordnance Disposal (EOD) robot interface can achieve complex neutralization techniques against realistic IEDs without the operator approaching at any time.

  17. Arm reduced robotic-assisted laparoscopic hysterectomy with transvaginal cuff closure.

    Science.gov (United States)

    Bodur, Serkan; Dede, Murat; Fidan, Ulas; Firatligil, Burcin F; Ulubay, Mustafa; Ozturk, Mustafa; Yenen, Mufit C

    2017-09-01

    The use of robotics for benign etiology in gynecology has not proven to be more beneficial when compared to traditional laparoscopy. The major concern regarding robotic hysterectomy stems from its high cost. To evaluate the clinical utility and effectiveness of one-arm reduced robotic-assisted laparoscopic hysterectomy as a cost-effective surgical option for total robotic hysterectomy. A sample population of 54 women who underwent robotic-assisted laparoscopic surgery for benign gynecologic indications was evaluated, and two groups were identified: (1) the two-armed robotic-assisted laparoscopic surgery group (n = 38 patients), and (2) the three-armed robotic-assisted laparoscopic surgery group (n = 16 patients). An increased cost was observed when three-armed robotic surgery was employed for benign gynecologic surgery (p < 0.001). The cost reduction observed in the study group was primarily derived from one robotic arm reduction and vaginal closure of the cuff. This cost reduction was achieved without an increase in complication rates or undesirable postoperative outcomes. An estimated profit between $399.5 and $421.5 was made for each patient depending on the suture material chosen for cuff closure. Two-armed surgery resulted in an 18.6% reduction in procedure-specific costs for robotic hysterectomy. Two-armed robotic-assisted laparoscopic hysterectomy appears to be a cost-effective solution for robotic gynecologic surgery. This surgical solution can be performed as effectively as classical three-armed robotic hysterectomies for benign indications without the risk of increased surgical-related morbidities. This approach has the potential to be a widely preferred surgical approach in medical communities where cost reduction is one of the primary determinants of surgery type.

  18. Mobile HTS-SQUID NDE system with robot arm and active shielding using fluxgate

    Energy Technology Data Exchange (ETDEWEB)

    Hatsukade, Y. [Department of Ecological Engineering, Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580 (Japan)], E-mail: hatukade@eco.tut.ac.jp; Yotsugi, K.; Tanaka, S. [Department of Ecological Engineering, Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580 (Japan)

    2008-09-15

    A robot-arm-based mobile HTS-SQUID NDE system was developed for inspection of advanced structures such as hydrogen fuel cell tanks. In order to realize stable operation of HTS-SQUID exposed in Earth's field and robot arm's noise without flux trapping, flux jumping and unlocking during motion, a new active magnetic shielding (AMS) technique using fluxgate was introduced. The high sensitive fluxgate, which could measure magnetic field of up to several 10 {mu}T, was mounted near an HTS-SQUID gradiometer on the robot arm to measure the ambient noise and feed back its output to a compensation coil, which surrounded both SQUID and fluxgate to cancel the ambient noise around them. The AMS technique successfully enabled the HTS-SQUID gradiometer to be moved at 10 mm/s by the robot arm in unshielded environment without flux trapping, jumping and unlocking. Detection of hidden slots in multi-layer composite-metal structures imitating the fuel cell tank was demonstrated.

  19. Research on the man in the loop control system of the robot arm based on gesture control

    Science.gov (United States)

    Xiao, Lifeng; Peng, Jinbao

    2017-03-01

    The Man in the loop control system of the robot arm based on gesture control research complex real-world environment, which requires the operator to continuously control and adjust the remote manipulator, as the background, completes the specific mission human in the loop entire system as the research object. This paper puts forward a kind of robot arm control system of Man in the loop based on gesture control, by robot arm control system based on gesture control and Virtual reality scene feedback to enhance immersion and integration of operator, to make operator really become a part of the whole control loop. This paper expounds how to construct a man in the loop control system of the robot arm based on gesture control. The system is a complex system of human computer cooperative control, but also people in the loop control problem areas. The new system solves the problems that the traditional method has no immersion feeling and the operation lever is unnatural, the adjustment time is long, and the data glove mode wears uncomfortable and the price is expensive.

  20. Research regarding the influence of driving-wires length change on positioning precision of a robotic arm

    Science.gov (United States)

    Ciofu, C.; Stan, G.

    2016-08-01

    The paper emphasise positioning precision of an elephant's trunk robotic arm which has joints driven by wires with variable length while operating The considered 5 degrees of freedom robotic arm has a particular structure of joint that makes possible inner actuation with wire-driven mechanism. We analyse solely the length change of wires as a consequence due inner winding and unwinding on joints for certain values of rotational angles. Variations in wires length entail joint angular displacements. We analyse positioning precision by taking into consideration equations from inverse kinematics of the elephant's trunk robotic arm. The angular displacements of joints are considered into computational method after partial derivation of positioning equations. We obtain variations of wires length at about tenths of micrometers. These variations employ angular displacements which are about minutes of sexagesimal degree and, thus, define positioning precision of elephant's trunk robotic arms. The analytical method is used for determining aftermath design structure of an elephant's trunk robotic arm with inner actuation through wires on positioning precision. Thus, designers could take suitable decisions on accuracy specifications limits of the robotic arm.

  1. Kinematics study and workspace analysis of an articulated robotic arm of a rpar

    International Nuclear Information System (INIS)

    Zeb, J.; Rashid, F.; Iqbal, N.

    2007-01-01

    An itinerant RPAR (Radiation Protection Assistant Robot) has been constructed to assist radiation workers in radiation area which are radiologically hazardous and beyond tile safe approach of radiation workers. The RPAR comprises of a cubicle tri- wheeled platform and a 4-DOF (Four Degree of Freedom) serial type articulated robotic arm. The movement of the platform is controlled by two differential wheeled driving systems. The Kinematics and Manipulator Jacobian of the end-effector (gripper) of the articulated robotic arm mounted on the RPAR were evaluated. The work space analyses of the articulated robotic arm have been carried out. The RPAR is helpful for surveillance of radiation zones, to pick and carry dropdown radioactive samples and sources, in routine radiological operations as well as during an emergency response to a radiological accident. The performance of the RPAR was found satisfactory. (author)

  2. The Development of Control System Design for 5 DOF Nuclear Malaysia Robot Arm v2

    International Nuclear Information System (INIS)

    Mohd Zaid Hassan; Anwar Abdul Rahman; Rosli Darmawan; Mohd Arif Hamzah

    2011-01-01

    This paper describes a general design and implementation approach used for programming and controlling robotic systems such as remotely operated robotic manipulator systems. A hierarchical approach to control system design is adopted. The hierarchical design is translated into a component-based software design. A low-cost robotic arm and controller system is presented. The controller is a modular model of the robotic arm with the same degrees of freedom whose joints are equipped with sensors. The system takes advantage of the low cost and wide availability of control components and uses a low-cost, easy-to-program microprocessor. Furthermore, it presents the design and the construction of electronic systems for the control of an articulated robot developed for research and development related with instrumentation and control. The system is simple but it is designed the motor to move the robot arm to proper angular position according to the input controller. Limitations of the micro controller are discussed, and suggestions for further development of the robot arm and control are made. (author)

  3. Optimization on robot arm machining by using genetic algorithms

    Science.gov (United States)

    Liu, Tung-Kuan; Chen, Chiu-Hung; Tsai, Shang-En

    2007-12-01

    In this study, an optimization problem on the robot arm machining is formulated and solved by using genetic algorithms (GAs). The proposed approach adopts direct kinematics model and utilizes GA's global search ability to find the optimum solution. The direct kinematics equations of the robot arm are formulated and can be used to compute the end-effector coordinates. Based on these, the objective of optimum machining along a set of points can be evolutionarily evaluated with the distance between machining points and end-effector positions. Besides, a 3D CAD application, CATIA, is used to build up the 3D models of the robot arm, work-pieces and their components. A simulated experiment in CATIA is used to verify the computation results first and a practical control on the robot arm through the RS232 port is also performed. From the results, this approach is proved to be robust and can be suitable for most machining needs when robot arms are adopted as the machining tools.

  4. Visual servo simulation of EAST articulated maintenance arm robot

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yang, E-mail: yangyang@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, 350 Shushanhu Rd, Hefei, Anhui (China); Song, Yuntao; Pan, Hongtao; Cheng, Yong; Feng, Hansheng [Institute of Plasma Physics, Chinese Academy of Sciences, 350 Shushanhu Rd, Hefei, Anhui (China); Wu, Huapeng [Lappeenranta University of Technology, Skinnarilankatu 34, Lappeenranta (Finland)

    2016-03-15

    For the inspection and light-duty maintenance of the vacuum vessel in the EAST tokamak, a serial robot arm, called EAST articulated maintenance arm, is developed. Due to the 9-m-long cantilever arm, the large flexibility of the EAMA robot introduces a problem in the accurate positioning. This article presents an autonomous robot control to cope with the robot positioning problem, which is a visual servo approach in context of tile grasping for the EAMA robot. In the experiments, the proposed method was implemented in a simulation environment to position and track a target graphite tile with the EAMA robot. As a result, the proposed visual control scheme can successfully drive the EAMA robot to approach and track the target tile until the robot reaches the desired position. Furthermore, the functionality of the simulation software presented in this paper is proved to be suitable for the development of the robotic and computer vision application.

  5. Visual servo simulation of EAST articulated maintenance arm robot

    International Nuclear Information System (INIS)

    Yang, Yang; Song, Yuntao; Pan, Hongtao; Cheng, Yong; Feng, Hansheng; Wu, Huapeng

    2016-01-01

    For the inspection and light-duty maintenance of the vacuum vessel in the EAST tokamak, a serial robot arm, called EAST articulated maintenance arm, is developed. Due to the 9-m-long cantilever arm, the large flexibility of the EAMA robot introduces a problem in the accurate positioning. This article presents an autonomous robot control to cope with the robot positioning problem, which is a visual servo approach in context of tile grasping for the EAMA robot. In the experiments, the proposed method was implemented in a simulation environment to position and track a target graphite tile with the EAMA robot. As a result, the proposed visual control scheme can successfully drive the EAMA robot to approach and track the target tile until the robot reaches the desired position. Furthermore, the functionality of the simulation software presented in this paper is proved to be suitable for the development of the robotic and computer vision application.

  6. Ultra light inspection robotic arm, design and modeling

    International Nuclear Information System (INIS)

    Voisembert, S.

    2012-01-01

    One of the major challenges in robotics is the improvement of inspections operations in confined and hazardous area using unmanned remote handling systems. Articulated arm are used in this case to carry some diagnostic tools for the inspection tasks. These long reach multi-link carriers should be characterized by a large workspace and reduced mass. Today, with about ten degrees of freedom and ten meters long they have reached their performance limit. Indeed, for long reach, the arm should have enough torque to carry its own weight plus the payload in cantilever mode and enough stiffness to minimize the deflection caused by the gravity. Despite the use of best materials and components, this kind of robot has reach its performance limit. Overcoming this limit needs a change in paradigm. Therefore a problem-solving, analysis and forecasting tool TRIZ (theory of inventive problem solving) is used. It leads naturally to identify the origin of the dilemma: the proper weight of the arm and so its mass under gravity. In particular, it proposes to postulate that a no-mass robot exists. An analysis of the properties of such a robot leads to the patented concept of an ultra light inflatable robot with unique and constant volume and constant diameter joints. This new object would benefit from advantages such as easy implementation, harmlessness toward its environment and so the ability to lean on it without damage. Therefore it could easily increase its range and its foreseen low-cost building would open a wide field of new applications. This thesis work, elaborates appropriate technical concepts and dimensioning methods for ultra light inflatable robots. The payload and length performances of an inflatable robot are analytically validated. Experimentations and a finite-element modeling are used for a pre-dimensioning of the joints and different modes of construction are prototyped in partnership with, specialized company in thigh-tech textile. The joints are also modeled with

  7. Controlling robot arm with the mind

    National Science Foundation

    2017-05-31

    Full Text Available Research test subjects at the University of Minnesota who were fitted with a specialized noninvasive brain cap were able to move a robotic arm just by imagining moving their own arms.

  8. Positioning the laparoscopic camera with industrial robot arm

    DEFF Research Database (Denmark)

    Capolei, Marie Claire; Wu, Haiyan; Andersen, Nils Axel

    2017-01-01

    This paper introduces a solution for the movement control of the laparoscopic camera employing a teleoperated robotic assistant. The project propose an autonomous robotic solution based on an industrial manipulator, provided with a modular software which is applicable to large scale. The robot arm...... industrial robot arm is designated to accomplish this manipulation task. The software is implemented in ROS in order to facilitate future extensions. The experimental results shows a manipulator capable of moving fast and smoothly the surgical tool around a remote center of motion....

  9. Noninvasive Electroencephalogram Based Control of a Robotic Arm for Reach and Grasp Tasks

    Science.gov (United States)

    Meng, Jianjun; Zhang, Shuying; Bekyo, Angeliki; Olsoe, Jaron; Baxter, Bryan; He, Bin

    2016-01-01

    Brain-computer interface (BCI) technologies aim to provide a bridge between the human brain and external devices. Prior research using non-invasive BCI to control virtual objects, such as computer cursors and virtual helicopters, and real-world objects, such as wheelchairs and quadcopters, has demonstrated the promise of BCI technologies. However, controlling a robotic arm to complete reach-and-grasp tasks efficiently using non-invasive BCI has yet to be shown. In this study, we found that a group of 13 human subjects could willingly modulate brain activity to control a robotic arm with high accuracy for performing tasks requiring multiple degrees of freedom by combination of two sequential low dimensional controls. Subjects were able to effectively control reaching of the robotic arm through modulation of their brain rhythms within the span of only a few training sessions and maintained the ability to control the robotic arm over multiple months. Our results demonstrate the viability of human operation of prosthetic limbs using non-invasive BCI technology. PMID:27966546

  10. Human-Automation Allocations for Current Robotic Space Operations

    Science.gov (United States)

    Marquez, Jessica J.; Chang, Mai L.; Beard, Bettina L.; Kim, Yun Kyung; Karasinski, John A.

    2018-01-01

    gather existing lessons learned and best practices in these role assignments, from spaceflight operational experience of crew and ground teams that may be used to guide development for future systems. NASA and other space agencies have operational spaceflight experience with two key Human-Automation-Robotic (HAR) systems: heavy lift robotic arms and planetary robotic explorers. Additionally, NASA has invested in high-fidelity rover systems that can carry crew, building beyond Apollo's lunar rover. The heavy lift robotic arms reviewed are: Space Station Remote Manipulator System (SSRMS), Japanese Remote Manipulator System (JEMRMS), and the European Robotic Arm (ERA, designed but not deployed in space). The robotic rover systems reviewed are: Mars Exploration Rovers, Mars Science Laboratory rover, and the high-fidelity K10 rovers. Much of the design and operational feedback for these systems have been communicated to flight controllers and robotic design teams. As part of the mitigating the HARI risk for future human spaceflight operations, we must document function allocations between robots and humans that have worked well in practice.

  11. Compliance Modeling and Error Compensation of a 3-Parallelogram Lightweight Robotic Arm

    DEFF Research Database (Denmark)

    Wu, Guanglei; Guo, Sheng; Bai, Shaoping

    2015-01-01

    This paper presents compliance modeling and error compensation for lightweight robotic arms built with parallelogram linkages, i.e., Π joints. The Cartesian stiffness matrix is derived using the virtual joint method. Based on the developed stiffness model, a method to compensate the compliance...... error is introduced, being illustrated with a 3-parallelogram robot in the application of pick-and-place operation. The results show that this compensation method can effectively improve the operation accuracy....

  12. Co-Simulation Control of Robot Arm Dynamics in ADAMS and MATLAB

    OpenAIRE

    Luo Haitao; Liu Yuwang; Chen Zhengcang; Leng Yuquan

    2013-01-01

    The main objective of this study is how to quickly establish the virtual prototyping model of robot arm system and effectively solve trajectory tracking control for a given signal. Taking the 2-DOF robot arm as an example, a co-simulation control method is introduced to research multi-body dynamics. Using Newton-Euler and Lagrange method, respectively establish the dynamics model of robot arm and verify the correctness of equations. Firstly, the physical model of robot arm was built by PROE a...

  13. Tracked Robot with Blade Arms to Enhance Crawling Capability

    OpenAIRE

    Jhu-Wei Ji; Fa-Shian Chang; Lih-Tyng Hwang; Chih-Feng Liu; Jeng-Nan Lee; Shun-Min Wang; Kai-Yi Cho

    2016-01-01

    This paper presents a tracked robot with blade arms powered to assist movement in difficult environments. As a result, the tracked robot is able to pass a ramp or climb stairs. The main feature is a pair of blade arms on both sides of the vehicle body working in collaboration with previously validated transformable track system. When the robot encounters an obstacle in a terrain, it enlists the blade arms with power to overcome the obstacle. In disaster areas, there usually will be terrains t...

  14. A Study of Accuracy and Time Delay for Bilateral Master-Slave Industrial Robotic Arm Manipulator System

    Directory of Open Access Journals (Sweden)

    Mansor Nuratiqa Natrah

    2018-01-01

    Full Text Available Bilateral master-slave industrial robotic arm manipulator system is an advanced technology used to help human to interact with environments that are unreachable to human, due to its remoteness or perilous. The system has been used in different areas such as tele-surgery, autonomous tele-operation for sea and space operation and handling explosive or high radiation operation fields. It is beneficial both for science and society. Remarkably, the system is not common and generally used in Malaysia. Likewise, the number of research conducted that focused about this technology in our country manufacturing industry are not yet discovered and existent. The implementation of this bilateral manipulator system in an industrial robot could be useful for industrial imminent and development over our country and people, specifically for production yield size and human operative. Hence, the study of bilateral robotic arm manipulator system in an industrial robot and analyzation of its performance and time delay in 3 differ controllers will be discussed to attest the efficiency and its effectiveness on the said design system. The experiment conducted was on KUKA youBot arm in V-Rep simulation with three different controllers (P, PD, PID.

  15. Analysis of reaching movements of upper arm in robot assisted exercises. Kinematic assessment of robot assisted upper arm reaching single-joint movements.

    Science.gov (United States)

    Iuppariello, Luigi; D'Addio, Giovanni; Romano, Maria; Bifulco, Paolo; Lanzillo, Bernardo; Pappone, Nicola; Cesarelli, Mario

    2016-01-01

    Robot-mediated therapy (RMT) has been a very dynamic area of research in recent years. Robotics devices are in fact capable to quantify the performances of a rehabilitation task in treatments of several disorders of the arm and the shoulder of various central and peripheral etiology. Different systems for robot-aided neuro-rehabilitation are available for upper limb rehabilitation but the biomechanical parameters proposed until today, to evaluate the quality of the movement, are related to the specific robot used and to the type of exercise performed. Besides, none study indicated a standardized quantitative evaluation of robot assisted upper arm reaching movements, so the RMT is still far to be considered a standardised tool. In this paper a quantitative kinematic assessment of robot assisted upper arm reaching movements, considering also the effect of gravity on the quality of the movements, is proposed. We studied a group of 10 healthy subjects and results indicate that our advised protocol can be useful for characterising normal pattern in reaching movements.

  16. Experiments on co-operating robot arms

    International Nuclear Information System (INIS)

    Arthaya, B.; De Schutter, J.

    1994-01-01

    When two robots manipulate a common object or perform a single task together, a closed-kinematic chain is formed. If both robots are controlled under position control only, at a certain phase during the manipulation, the interaction forces may become unacceptably high. The interaction forces are caused by the kinematic as well as the dynamic errors in the robot position controller. In order to avoid this problem, a synchronized motion between both robots has to be generated, not only by controlling the position (velocity) of the two end-effectors, but also by controlling the interaction forces between them. In order to generate a synchronized motion, the first robot controller continuously modifies the task frame velocity corresponding to the velocity of the other robot. This implies that the velocity of the other robot is used as feed-forward information in order to anticipate its motion. This approach results in a better tracking behaviour

  17. Manual input device for controlling a robot arm

    International Nuclear Information System (INIS)

    Fischer, P.J.; Siva, K.V.

    1990-01-01

    A six-axis input device, eg joystick, is supported by a mechanism which enables the joystick to be aligned with any desired orientation, eg parallel to the tool. The mechanism can then be locked to provide a rigid support of the joystick. The mechanism may include three pivotal joints whose axes are perpendicular, each incorporating a clutch. The clutches may be electromagnetic or mechanical and may be operable jointly or independently. The robot arm comprises a base rotatable about a vertical axis, an upper arm, a forearm and a tool or grip rotatable about three perpendicular axes relative to the forearm. (author)

  18. Visual Recognition and Its Application to Robot Arm Control

    Directory of Open Access Journals (Sweden)

    Jih-Gau Juang

    2015-10-01

    Full Text Available This paper presents an application of optical word recognition and fuzzy control to a smartphone automatic test system. The system consists of a robot arm and two webcams. After the words from the control panel that represent commands are recognized by the robot system, the robot arm performs the corresponding actions to test the smartphone. One of the webcams is utilized to capture commands on the screen of the control panel, the other to recognize the words on the screen of the tested smartphone. The method of image processing is based on the Red-Green-Blue (RGB and Hue-Saturation-Luminance (HSL color spaces to reduce the influence of light. Fuzzy theory is used in the robot arm’s position control. The Optical Character Recognition (OCR technique is applied to the word recognition, and the recognition results are then checked by a dictionary process to increase the recognition accuracy. The camera which is used to recognize the tested smartphone also provides object coordinates to the fuzzy controller, then the robot arm moves to the desired positions and presses the desired buttons. The proposed control scheme allows the robot arm to perform different assigned test functions successfully.

  19. Optimal Control of Holding Motion by Nonprehensile Two-Cooperative-Arm Robot

    Directory of Open Access Journals (Sweden)

    Changan Jiang

    2016-01-01

    Full Text Available Recently, more researchers have focused on nursing-care assistant robot and placed their hope on it to solve the shortage problem of the caregivers in hospital or nursing home. In this paper, a nonprehensile two-cooperative-arm robot is considered to realize holding motion to keep a two-rigid-link object (regarded as a care-receiver stable on the robot arms. By applying Newton-Euler equations of motion, dynamic model of the object is obtained. In this model, for describing interaction behavior between object and robot arms in the normal direction, a viscoelastic model is employed to represent the normal forces. Considering existence of friction between object and robot arms, LuGre dynamic model is applied to describe the friction. Based on the obtained model, an optimal regulator is designed to control the holding motion of two-cooperative-arm robot. In order to verify the effectiveness of the proposed method, simulation results are shown.

  20. Design of a Lightweight Soft Robotic Arm Using Pneumatic Artificial Muscles and Inflatable Sleeves.

    Science.gov (United States)

    Ohta, Preston; Valle, Luis; King, Jonathan; Low, Kevin; Yi, Jaehyun; Atkeson, Christopher G; Park, Yong-Lae

    2018-04-01

    As robots begin to interact with humans and operate in human environments, safety becomes a major concern. Conventional robots, although reliable and consistent, can cause injury to anyone within its range of motion. Soft robotics, wherein systems are made to be soft and mechanically compliant, are thus a promising alternative due to their lightweight nature and ability to cushion impacts, but current designs often sacrifice accuracy and usefulness for safety. We, therefore, have developed a bioinspired robotic arm combining elements of rigid and soft robotics such that it exhibits the positive qualities of both, namely compliance and accuracy, while maintaining a low weight. This article describes the design of a robotic arm-wrist-hand system with seven degrees of freedom (DOFs). The shoulder and elbow each has two DOFs for two perpendicular rotational motions on each joint, and the hand has two DOFs for wrist rotations and one DOF for a grasp motion. The arm is pneumatically powered using custom-built McKibben type pneumatic artificial muscles, which are inflated and deflated using binary and proportional valves. The wrist and hand motions are actuated through servomotors. In addition to the actuators, the arm is equipped with a potentiometer in each joint for detecting joint angle changes. Simulation and experimental results for closed-loop position control are also presented in the article.

  1. Effect of Link Flexibility on tip position of a single link robotic arm

    Science.gov (United States)

    Madhusudan Raju, E.; Siva Rama Krishna, L.; Mouli, Y. Sharath Chandra; Nageswara Rao, V.

    2015-12-01

    The flexible robots are widely used in space applications due to their quick response, lower energy consumption, lower overall mass and operation at high speed compared to conventional industrial rigid link robots. These robots are inherently flexible, so that the kinematics of flexible robots can't be solved with rigid body assumptions. The flexibility in links and joints affects end-point positioning accuracy of the robot. It is important to model the link kinematics with precision which in turn simplifies modelling of dynamics of flexible robots. The main objective of this paper is to evaluate the effect of link flexibility on a tip position of a single link robotic arm for a given motion. The joint is assumed to be rigid and only link flexibility is considered. The kinematics of flexible link problem is evaluated by Assumed Modes Method (AMM) using MAT LAB Programming. To evaluate the effect of link flexibility (with and without payload) of robotic arm, the normalized tip deviation is found for flexible link with respect to a rigid link. Finally, the limiting inertia for payload mass is found if the allowable tip deviation is 5%.

  2. Kinematics analysis on hinges of robot arm gripper for harmful chemical handling

    Science.gov (United States)

    Razali, Zol Bahri; Kader, Mohamed Mydin M. Abdul; Mustafa, Nurul Fahimah; Daud, Mohd Hisam

    2017-09-01

    The development of manufacturing industry is booming the application of industrial robot, and proportional to the use of robot arm. Some of the purpose of robot arm gripper is to sort things and place to the proper place. And some of the things are harmful to human, such as harmful chemical. By using robot arm to do picking and placing, it is expected to replace human tasks, as well as to reduce human from the harmful job. The problem of the robot arm gripper, most likely the problem of hinge, thus the analysis on the hinges of robot arm gripper to prevent claw is essential. By using robot arm, instead of human, is labored to do the harmful tasks and unexpected accident happen, costs and expenses in handling injured employee due to the harmful chemicals can be minimized. Thus the objective of this project is to make a kinematics analysis on the hinges of the robot arm gripper. Suitable material such as steel structure has also been selected for the construction of this hinges. This material has properties associated with compressive strength, fire resistance, corrosion and has a shape that is easy to move. Solid Works and ANSYS software is used to create animated movement on the design model and to detect deficiencies in the hinges. Detail methodology is described in this paper.

  3. MAHLI on Mars: lessons learned operating a geoscience camera on a landed payload robotic arm

    Science.gov (United States)

    Aileen Yingst, R.; Edgett, Kenneth S.; Kennedy, Megan R.; Krezoski, Gillian M.; McBride, Marie J.; Minitti, Michelle E.; Ravine, Michael A.; Williams, Rebecca M. E.

    2016-06-01

    The Mars Hand Lens Imager (MAHLI) is a 2-megapixel, color camera with resolution as high as 13.9 µm pixel-1. MAHLI has operated successfully on the Martian surface for over 1150 Martian days (sols) aboard the Mars Science Laboratory (MSL) rover, Curiosity. During that time MAHLI acquired images to support science and science-enabling activities, including rock and outcrop textural analysis; sand characterization to further the understanding of global sand properties and processes; support of other instrument observations; sample extraction site documentation; range-finding for arm and instrument placement; rover hardware and instrument monitoring and safety; terrain assessment; landscape geomorphology; and support of rover robotic arm commissioning. Operation of the instrument has demonstrated that imaging fully illuminated, dust-free targets yields the best results, with complementary information obtained from shadowed images. The light-emitting diodes (LEDs) allow satisfactory night imaging but do not improve daytime shadowed imaging. MAHLI's combination of fine-scale, science-driven resolution, RGB color, the ability to focus over a large range of distances, and relatively large field of view (FOV), have maximized the return of science and science-enabling observations given the MSL mission architecture and constraints.

  4. Four Degree Freedom Robot Arm with Fuzzy Neural Network Control

    Directory of Open Access Journals (Sweden)

    Şinasi Arslan

    2013-01-01

    Full Text Available In this study, the control of four degree freedom robot arm has been realized with the computed torque control method.. It is usually required that the four jointed robot arm has high precision capability and good maneuverability for using in industrial applications. Besides, high speed working and external applied loads have been acting as important roles. For those purposes, the computed torque control method has been developed in a good manner that the robot arm can track the given trajectory, which has been able to enhance the feedback control together with fuzzy neural network control. The simulation results have proved that the computed torque control with the neural network has been so successful in robot control.

  5. Electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength after stroke.

    Science.gov (United States)

    Mehrholz, Jan; Pohl, Marcus; Platz, Thomas; Kugler, Joachim; Elsner, Bernhard

    2015-11-07

    Electromechanical and robot-assisted arm training devices are used in rehabilitation, and may help to improve arm function after stroke. To assess the effectiveness of electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength in people after stroke. We also assessed the acceptability and safety of the therapy. We searched the Cochrane Stroke Group's Trials Register (last searched February 2015), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library 2015, Issue 3), MEDLINE (1950 to March 2015), EMBASE (1980 to March 2015), CINAHL (1982 to March 2015), AMED (1985 to March 2015), SPORTDiscus (1949 to March 2015), PEDro (searched April 2015), Compendex (1972 to March 2015), and Inspec (1969 to March 2015). We also handsearched relevant conference proceedings, searched trials and research registers, checked reference lists, and contacted trialists, experts, and researchers in our field, as well as manufacturers of commercial devices. Randomised controlled trials comparing electromechanical and robot-assisted arm training for recovery of arm function with other rehabilitation or placebo interventions, or no treatment, for people after stroke. Two review authors independently selected trials for inclusion, assessed trial quality and risk of bias, and extracted data. We contacted trialists for additional information. We analysed the results as standardised mean differences (SMDs) for continuous variables and risk differences (RDs) for dichotomous variables. We included 34 trials (involving 1160 participants) in this update of our review. Electromechanical and robot-assisted arm training improved activities of daily living scores (SMD 0.37, 95% confidence interval (CI) 0.11 to 0.64, P = 0.005, I² = 62%), arm function (SMD 0.35, 95% CI 0.18 to 0.51, P arm muscle strength (SMD 0.36, 95% CI 0.01 to 0.70, P = 0.04, I² = 72%), but the quality of the evidence was low to very low

  6. Robust coordinated control of a dual-arm space robot

    Science.gov (United States)

    Shi, Lingling; Kayastha, Sharmila; Katupitiya, Jay

    2017-09-01

    Dual-arm space robots are more capable of implementing complex space tasks compared with single arm space robots. However, the dynamic coupling between the arms and the base will have a serious impact on the spacecraft attitude and the hand motion of each arm. Instead of considering one arm as the mission arm and the other as the balance arm, in this work two arms of the space robot perform as mission arms aimed at accomplishing secure capture of a floating target. The paper investigates coordinated control of the base's attitude and the arms' motion in the task space in the presence of system uncertainties. Two types of controllers, i.e. a Sliding Mode Controller (SMC) and a nonlinear Model Predictive Controller (MPC) are verified and compared with a conventional Computed-Torque Controller (CTC) through numerical simulations in terms of control accuracy and system robustness. Both controllers eliminate the need to linearly parameterize the dynamic equations. The MPC has been shown to achieve performance with higher accuracy than CTC and SMC in the absence of system uncertainties under the condition that they consume comparable energy. When the system uncertainties are included, SMC and CTC present advantageous robustness than MPC. Specifically, in a case where system inertia increases, SMC delivers higher accuracy than CTC and costs the least amount of energy.

  7. Space robotics--DLR's telerobotic concepts, lightweight arms and articulated hands.

    Science.gov (United States)

    Hirzinger, G; Brunner, B; Landzettel, K; Sporer, N; Butterfass, J; Schedl, M

    2003-01-01

    The paper briefly outlines DLR's experience with real space robot missions (ROTEX and ETS VII). It then discusses forthcoming projects, e.g., free-flying systems in low or geostationary orbit and robot systems around the space station ISS, where the telerobotic system MARCO might represent a common baseline. Finally it describes our efforts in developing a new generation of "mechatronic" ultra-light weight arms with multifingered hands. The third arm generation is operable now (approaching present-day technical limits). In a similar way DLR's four-fingered hand II was a big step towards higher reliability and yet better performance. Artificial robonauts for space are a central goal now for the Europeans as well as for NASA, and the first verification tests of DLR's joint components are supposed to fly already end of 93 on the space station.

  8. A Remote Controlled Robotic Arm That Reads Barcodes and Handles Products

    Directory of Open Access Journals (Sweden)

    Zhi-Ying Chen

    2018-03-01

    Full Text Available In this study, a 6-axis robotic arm, which was controlled by an embedded Raspberry Pi with onboard WiFi, was developed and fabricated. A mobile application (APP, designed for the purpose, was used to operate and monitor a robotic arm by means of a WiFi connection. A computer vision was used to read common one-dimensional barcode (EAN code for the handling and identification of products such as milk tea drinks, sodas and biscuits. The gripper on the end of the arm could sense the clamping force and allowed real-time control of the amount of force used to hold and handle the products. The packages were all made of different material and this control allowed them to be handled without danger of damage or deformation. The maximum handling torque used was ~1.08 Nm and the mechanical design allowed the force of the gripper to be uniformly applied to the sensor to ensure accurate measurement of the force.

  9. A Simple Solution for Programming of a Robotic Arm

    Directory of Open Access Journals (Sweden)

    Bogdan Laurean

    2014-12-01

    Full Text Available This paper presents a method to actuate, programming and control of a Robotic arm based on a monomobil telescopic planetary gear and a DC motor. Experimental model of robot was designed and manufactured at the Faculty of Engineering from Sibiu, (Patent no. 112418 CI6.B25J 18/02. The DC motor as actuator rotates a reel. The wires on the reel will produce a linear displacement of telescopic modules. The command of the DC motor is realized by a programmable logic controller. The outputs of the programmable logic controller are connected in a "H" bridge. The rotation of the reel in one direction or another has the effect of lengthening or shortening the robotic arm. The value of robotic arm length is monitored by an optical incremental encoder. The value of displacement will correspond to number of steps from an up/down counter.

  10. Integrating Soft Robotics with the Robot Operating System: A Hybrid Pick and Place Arm

    Directory of Open Access Journals (Sweden)

    Ross M. McKenzie

    2017-08-01

    Full Text Available Soft robotic systems present a variety of new opportunities for solving complex problems. The use of soft robotic grippers, for example, can simplify the complexity in tasks such as the grasping of irregular and delicate objects. Adoption of soft robotics by the informatics community and industry, however, has been slow and this is, in-part, due to the amount of hardware and software that must be developed from scratch for each use of soft system components. In this paper, we detail the design, fabrication, and validation of an open-source framework that we designed to lower the barrier to entry for integrating soft robotic subsystems. This framework is built on the robot operating system (ROS, and we use it to demonstrate a modular, soft–hard hybrid system, which is capable of completing pick and place tasks. By lowering this barrier to entry through our open sourced hardware and software, we hope that system designers and Informatics researchers will find it easy to integrate soft components into their existing ROS-enabled robotic systems.

  11. The Development of light-weight 2-link robot arm for high radiation area

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ho Cheol; Seo, Yong Chil; Jung, Kyung Min; Choi, Young Soo

    2009-10-15

    A light-weight 2-link robot arm which weight is less than 8kg was developed for treating the small radio-active material in the high radiation area such as nuclear power plants and NDT area. The light-weight 2-link robot arm can be attached on a small mobile robot and carry out tasks. It is a 5 DOF robot arm including a gripper

  12. Robotic Mirror Therapy System for Functional Recovery of Hemiplegic Arms.

    Science.gov (United States)

    Beom, Jaewon; Koh, Sukgyu; Nam, Hyung Seok; Kim, Wonshik; Kim, Yoonjae; Seo, Han Gil; Oh, Byung-Mo; Chung, Sun Gun; Kim, Sungwan

    2016-08-15

    Mirror therapy has been performed as effective occupational therapy in a clinical setting for functional recovery of a hemiplegic arm after stroke. It is conducted by eliciting an illusion through use of a mirror as if the hemiplegic arm is moving in real-time while moving the healthy arm. It can facilitate brain neuroplasticity through activation of the sensorimotor cortex. However, conventional mirror therapy has a critical limitation in that the hemiplegic arm is not actually moving. Thus, we developed a real-time 2-axis mirror robot system as a simple add-on module for conventional mirror therapy using a closed feedback mechanism, which enables real-time movement of the hemiplegic arm. We used 3 Attitude and Heading Reference System sensors, 2 brushless DC motors for elbow and wrist joints, and exoskeletal frames. In a feasibility study on 6 healthy subjects, robotic mirror therapy was safe and feasible. We further selected tasks useful for activities of daily living training through feedback from rehabilitation doctors. A chronic stroke patient showed improvement in the Fugl-Meyer assessment scale and elbow flexor spasticity after a 2-week application of the mirror robot system. Robotic mirror therapy may enhance proprioceptive input to the sensory cortex, which is considered to be important in neuroplasticity and functional recovery of hemiplegic arms. The mirror robot system presented herein can be easily developed and utilized effectively to advance occupational therapy.

  13. Walking Pattern Generation of Dual-Arm Mobile Robot Using Preview Controller

    OpenAIRE

    P. Wu; W. Wu

    2012-01-01

    Based on the stability request of robot’s moving on the ground, the motion planning of dual-arm mobile robot when moving on the ground is studied and the preview control system is applied in the robot walking pattern generation. Direct question of robot kinematics in the extended task space is analyzed according to Degrees of Freedom configuration of the dual-arm mobile robot. It is proved that the preview control system could be used in the generation of robot Center of Mass forward trajecto...

  14. Extended Kalman filtering applied to a two-axis robotic arm with flexible links

    Energy Technology Data Exchange (ETDEWEB)

    Lertpiriyasuwat, V.; Berg, M.C.; Buffinton, K.W.

    2000-03-01

    An industrial robot today uses measurements of its joint positions and models of its kinematics and dynamics to estimate and control its end-effector position. Substantially better end-effector position estimation and control performance would be obtainable if direct measurements of its end-effector position were also used. The subject of this paper is extended Kalman filtering for precise estimation of the position of the end-effector of a robot using, in addition to the usual measurements of the joint positions, direct measurements of the end-effector position. The estimation performances of extended Kalman filters are compared in applications to a planar two-axis robotic arm with very flexible links. The comparisons shed new light on the dependence of extended Kalman filter estimation performance on the quality of the model of the arm dynamics that the extended Kalman filter operates with.

  15. Interface Based on Electrooculography for Velocity Control of a Robot Arm

    Directory of Open Access Journals (Sweden)

    Eduardo Iáñez

    2010-01-01

    Full Text Available This paper describes a technique based on electrooculography to control a robot arm. This technique detects the movement of the eyes, measuring the difference of potential between the cornea and the retina by placing electrodes around the ocular area. The processing algorithm developed to obtain the position of the eye at the blink of the user is explained. The output of the processing algorithm offers, apart from the direction, four different values (zero to three to control the velocity of the robot arm according to how much the user is looking in one direction. This allows controlling two degrees of freedom of a robot arm with the eyes movement. The blink has been used to mark some targets in tests. In this paper, the experimental results obtained with a real robot arm are shown.

  16. Bioinspired locomotion and grasping in water: the soft eight-arm OCTOPUS robot.

    Science.gov (United States)

    Cianchetti, M; Calisti, M; Margheri, L; Kuba, M; Laschi, C

    2015-05-13

    The octopus is an interesting model for the development of soft robotics, due to its high deformability, dexterity and rich behavioural repertoire. To investigate the principles of octopus dexterity, we designed an eight-arm soft robot and evaluated its performance with focused experiments. The OCTOPUS robot presented here is a completely soft robot, which integrates eight arms extending in radial direction and a central body which contains the main processing units. The front arms are mainly used for elongation and grasping, while the others are mainly used for locomotion. The robotic octopus works in water and its buoyancy is close to neutral. The experimental results show that the octopus-inspired robot can walk in water using the same strategy as the animal model, with good performance over different surfaces, including walking through physical constraints. It can grasp objects of different sizes and shapes, thanks to its soft arm materials and conical shape.

  17. A Non-linear Model for Predicting Tip Position of a Pliable Robot Arm Segment Using Bending Sensor Data

    Directory of Open Access Journals (Sweden)

    Elizabeth I. SKLAR

    2016-04-01

    Full Text Available Using pliable materials for the construction of robot bodies presents new and interesting challenges for the robotics community. Within the EU project entitled STIFFness controllable Flexible & Learnable manipulator for surgical Operations (STIFF-FLOP, a bendable, segmented robot arm has been developed. The exterior of the arm is composed of a soft material (silicone, encasing an internal structure that contains air-chamber actuators and a variety of sensors for monitoring applied force, position and shape of the arm as it bends. Due to the physical characteristics of the arm, a proper model of robot kinematics and dynamics is difficult to infer from the sensor data. Here we propose a non-linear approach to predicting the robot arm posture, by training a feed-forward neural network with a structured series of pressures values applied to the arm's actuators. The model is developed across a set of seven different experiments. Because the STIFF-FLOP arm is intended for use in surgical procedures, traditional methods for position estimation (based on visual information or electromagnetic tracking will not be possible to implement. Thus the ability to estimate pose based on data from a custom fiber-optic bending sensor and accompanying model is a valuable contribution. Results are presented which demonstrate the utility of our non-linear modelling approach across a range of data collection procedures.

  18. End-Effector Position Analysis Using Forward Kinematics For 5 Dof Pravak Robot Arm

    Directory of Open Access Journals (Sweden)

    Jolly Atit Shah

    2013-03-01

    Full Text Available Automatic control of the robotic manipulator involves study of kinematics and dynamics as a major issue. This paper involves the kinematic analysis of a Pravak Robot arm which is used for doing successful robotic manipulation task in its workspace. The Pravak Robot Arm is a 5-DOF robot having all the joints revolute. The kinematics problem is defined as the transformation from the Cartesian space to the joint space and vice versa. In this study the Denavit- Hartenberg (D-H model is used to model robot links and joints. Pravak Robot Arm is a simple and safe robotic system designed for laboratory training and research applications. This robot allows to gain theoretical and practical experience in robotics, automation and control systems. The MATLAB R2007 is used to analyse end effectors position for a set of joint parameter.

  19. Major upgrade of the articulated inspection arm control system to fulfill daily operation requirements

    Energy Technology Data Exchange (ETDEWEB)

    Pastor, P., E-mail: patrick.pastor@cea.fr [CEA, IRFM, Institut de Recherche sur la Fusion par confinement Magnétique (France); Villedieu, E.; Allegretti, L.; Vincent, B.; Barbuti, A.; Bruno, V.; Coquillat, P.; Dechelle, C.; Gargiulo, L.; Le, R.; Malard, P.; Martinez, A.; Nouailletas, R. [CEA, IRFM, Institut de Recherche sur la Fusion par confinement Magnétique (France); Yuntao, Song; Yong, Cheng; Chen, Liu; Hansheng, Feng; Shanshuang, Shi [ASIPP, Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China)

    2015-10-15

    Highlights: • We propose an overview of the work which has been done to upgrade the control system of the AIA robot (articulated inspection arm) to fulfill daily operation requirements for tokamak inspection. • The control system is based on the use of new position sensors, new electronics design and new supervisor software. • Final tests are ongoing in the EAST scale 1 tokamak mock-up. Routine operation of the robot at EAST will start in the beginning of 2015. - Abstract: An articulated inspection arm (AIA) has been developed by CEA for visual inspection between pulses inside the Tore Supra tokamak vacuum vessel without breaking temperature and vacuum conditions. The eight meters length robot is composed of a shuttle and six articulated segments with a video camera at its end. A demonstration prototype has been achieved in 2008 at Tore Supra (Gargiulo, 2007; Houry, 2008; Perrot, 2003). A project to upgrade the AIA into a fully operational robot has been undertaken by IRFM and ASIPP in an Associated Laboratory. It will be in operation first in the EAST machine and afterwards in Tore Supra in its WEST (W/Tungsten Environment in Steady-state Tokamak) configuration where it is of paramount importance to survey possible degradation of W component surface. The control system of the robot has been extensively upgraded. The effort has been focused on three areas: (1) improvement of the arm position accuracy, (2) increase of the operational robustness, (3) use of a powerful graphical user interface including simulation of trajectories and robot deployment capabilities in a 3D viewer environment. The aim of this paper is to detail the architecture of the AIA control system.

  20. Biologically inspired control of humanoid robot arms robust and adaptive approaches

    CERN Document Server

    Spiers, Adam; Herrmann, Guido

    2016-01-01

    This book investigates a biologically inspired method of robot arm control, developed with the objective of synthesising human-like motion dynamically, using nonlinear, robust and adaptive control techniques in practical robot systems. The control method caters to a rising interest in humanoid robots and the need for appropriate control schemes to match these systems. Unlike the classic kinematic schemes used in industrial manipulators, the dynamic approaches proposed here promote human-like motion with better exploitation of the robot’s physical structure. This also benefits human-robot interaction. The control schemes proposed in this book are inspired by a wealth of human-motion literature that indicates the drivers of motion to be dynamic, model-based and optimal. Such considerations lend themselves nicely to achievement via nonlinear control techniques without the necessity for extensive and complex biological models. The operational-space method of robot control forms the basis of many of the techniqu...

  1. Design and Implementation of Fire Extinguisher Robot with Robotic Arm

    Directory of Open Access Journals (Sweden)

    Memon Abdul Waris

    2018-01-01

    Full Text Available Robot is a device, which performs human task or behave like a human-being. It needs expertise skills and complex programming to design. For designing a fire fighter robot, many sensors and motors were used. User firstly send robot to an affected area, to get live image of the field with the help of mobile camera via Wi-Fi using IP camera application to laptop. If any signs of fire shown in image, user direct robot in that particular direction for confirmation. Fire sensor and temperature sensor detects and measures the reading, after confirmation robot sprinkle water on affected field. During extinguish process if any obstacle comes in between the prototype and the affected area the ultrasonic sensor detects the obstacle, in response the robotic arm moves to pick and place that obstacle to another location for clearing the path. Meanwhile if any poisonous gas is present, the gas sensor detects and indicates by making alarm.

  2. Operator-centered control of a semi-autonomous industrial robot

    International Nuclear Information System (INIS)

    Spelt, P.F.; Jones, S.L.

    1994-01-01

    This paper presents work done by Oak Ridge National Laboratory and Remotec, Inc., to develop a new operator-centered control system for Remotec's Andros telerobot. Andros robots are presently used by numerous electric utilities, the armed forces, and numerous law enforcement agencies to perform tasks which are hazardous for human operators. This project has automated task components and enhanced the video graphics display of the robot's position in the environment to significantly reduce operator workload. The procedure of automating a telerobot requires the addition of computer power to the robot, along with a variety of sensors and encoders to provide information about the robots performance in and relationship to its environment The resulting vehicle serves as a platform for research on strategies to integrate automated tasks with those performed by a human operator. The addition of these capabilities will greatly enhance the safety and efficiency of performance in hazardous environments

  3. Pick-up, transport and release of a molecular cargo using a small-molecule robotic arm

    Science.gov (United States)

    Kassem, Salma; Lee, Alan T. L.; Leigh, David A.; Markevicius, Augustinas; Solà, Jordi

    2016-02-01

    Modern-day factory assembly lines often feature robots that pick up, reposition and connect components in a programmed manner. The idea of manipulating molecular fragments in a similar way has to date only been explored using biological building blocks (specifically DNA). Here, we report on a wholly artificial small-molecule robotic arm capable of selectively transporting a molecular cargo in either direction between two spatially distinct, chemically similar, sites on a molecular platform. The arm picks up/releases a 3-mercaptopropanehydrazide cargo by formation/breakage of a disulfide bond, while dynamic hydrazone chemistry controls the cargo binding to the platform. Transport is controlled by selectively inducing conformational and configurational changes within an embedded hydrazone rotary switch that steers the robotic arm. In a three-stage operation, 79-85% of 3-mercaptopropanehydrazide molecules are transported in either (chosen) direction between the two platform sites, without the cargo at any time fully dissociating from the machine nor exchanging with other molecules in the bulk.

  4. Robot-arm-based mobile HTS SQUID system for NDE of structures

    Energy Technology Data Exchange (ETDEWEB)

    Yotsugi, K; Hatsukade, Y; Tanaka, S [Department of Ecological Engineering, Toyohashi University of Technology, 1-1 Hibarigaoka, Tenpaku-cho, Toyohashi, Aichi 441-8580 (Japan)], E-mail: hatukade@eco.tut.ac.jp

    2008-02-01

    A robot-arm-based mobile HTS SQUID system was developed for NDE of fixed targets. To realize the system, active magnetic shielding technique using fluxgate as reference sensor for ambient field was applied to a cryocooler-based HTS SQUID gradiometer that was mounted on commercial robot-arm. In this technique, ambient field noise and pulse noise of 550 nT from robot were measured by the fluxgate near the SQUID, and then the fluxgate output was negatively fed back to generate compensation field around the SQUID and fluxgate. The noise from robot was reduced by a factor of about 20 and the shielding technique enabled the HTS SQUID to move in unshielded environment by the robot-arm without flux-trapping or unlocking at 10 mm/s. System noise measurement and inspection of hidden cracks in multi-layer composite-metal structure were demonstrated using the mobile SQUID-NDE system.

  5. Fuzzy Logic and PID control of a 3 DOF Robotic Arm

    Directory of Open Access Journals (Sweden)

    Korhan Kayışlı

    2017-12-01

    Full Text Available The robotic arms are used in many industrial applications at the present time. At this point, high precision control is required for robotics used in fields such as healthcare area. Therefore, the control method applied to robots is also important. In this study, a force was applied to the end function of a three degree-of-freedom robot and the robustness of the controllers are tested. PID and Fuzzy Logic control method are used for this process. The control process of robotic arm which is designed and simulated is obtained by using Fuzzy Logic and classical PID controllers and the results are presented comparatively

  6. Fuzzy-Genetic Optimal Control for Four Degreeof Freedom Robotic Arm Movement

    OpenAIRE

    V. K. Banga; R. Kumar; Y. Singh

    2009-01-01

    In this paper, we present optimal control for movement and trajectory planning for four degrees-of-freedom robot using Fuzzy Logic (FL) and Genetic Algorithms (GAs). We have evaluated using Fuzzy Logic (FL) and Genetic Algorithms (GAs) for four degree-of-freedom (4 DOF) robotics arm, Uncertainties like; Movement, Friction and Settling Time in robotic arm movement have been compensated using Fuzzy logic and Genetic Algorithms. The development of a fuzzy genetic optimizatio...

  7. Advanced real-time multi-display educational system (ARMES): An innovative real-time audiovisual mentoring tool for complex robotic surgery.

    Science.gov (United States)

    Lee, Joong Ho; Tanaka, Eiji; Woo, Yanghee; Ali, Güner; Son, Taeil; Kim, Hyoung-Il; Hyung, Woo Jin

    2017-12-01

    The recent scientific and technologic advances have profoundly affected the training of surgeons worldwide. We describe a novel intraoperative real-time training module, the Advanced Robotic Multi-display Educational System (ARMES). We created a real-time training module, which can provide a standardized step by step guidance to robotic distal subtotal gastrectomy with D2 lymphadenectomy procedures, ARMES. The short video clips of 20 key steps in the standardized procedure for robotic gastrectomy were created and integrated with TilePro™ software to delivery on da Vinci Surgical Systems (Intuitive Surgical, Sunnyvale, CA). We successfully performed the robotic distal subtotal gastrectomy with D2 lymphadenectomy for patient with gastric cancer employing this new teaching method without any transfer errors or system failures. Using this technique, the total operative time was 197 min and blood loss was 50 mL and there were no intra- or post-operative complications. Our innovative real-time mentoring module, ARMES, enables standardized, systematic guidance during surgical procedures. © 2017 Wiley Periodicals, Inc.

  8. Hand Gesture Based Wireless Robotic Arm Control for Agricultural Applications

    Science.gov (United States)

    Kannan Megalingam, Rajesh; Bandhyopadhyay, Shiva; Vamsy Vivek, Gedela; Juned Rahi, Muhammad

    2017-08-01

    One of the major challenges in agriculture is harvesting. It is very hard and sometimes even unsafe for workers to go to each plant and pluck fruits. Robotic systems are increasingly combined with new technologies to automate or semi automate labour intensive work, such as e.g. grape harvesting. In this work we propose a semi-automatic method for aid in harvesting fruits and hence increase productivity per man hour. A robotic arm fixed to a rover roams in the in orchard and the user can control it remotely using the hand glove fixed with various sensors. These sensors can position the robotic arm remotely to harvest the fruits. In this paper we discuss the design of hand glove fixed with various sensors, design of 4 DoF robotic arm and the wireless control interface. In addition the setup of the system and the testing and evaluation under lab conditions are also presented in this paper.

  9. Dual-arm manipulation module for use in decontamination and decommissioning operations

    International Nuclear Information System (INIS)

    Hamel, W.R.; Haley, D.C.; Dixon, W.E.

    1994-01-01

    A dual-arm manipulation module is under development for application in decontamination and decommissioning (D ampersand D) tasks. The development is led by Oak Ridge National Laboratory with support from Sandia National Laboratories, and with university and industry participation. The project is part of the Robotics Technology Development Program funded by the US Department of Energy, Environmental Restoration and Waste Management, Office of Technology Development. The dual-arm module is designed to provide dexterous manipulation capability for remote characterization, decontamination, and dismantlement operations, and the module is reconfigurable to meet various deployment requirements. Remote manipulation capability can benefit D ampersand D activities through reduced worker exposure to both contaminant and industrial hazards. When tasks conditions permit, increased use of robotic features reduce costs by increased efficiency of operation

  10. Macrobend optical sensing for pose measurement in soft robot arms

    International Nuclear Information System (INIS)

    Sareh, Sina; Noh, Yohan; Liu, Hongbin; Althoefer, Kaspar; Li, Min; Ranzani, Tommaso

    2015-01-01

    This paper introduces a pose-sensing system for soft robot arms integrating a set of macrobend stretch sensors. The macrobend sensory design in this study consists of optical fibres and is based on the notion that bending an optical fibre modulates the intensity of the light transmitted through the fibre. This sensing method is capable of measuring bending, elongation and compression in soft continuum robots and is also applicable to wearable sensing technologies, e.g. pose sensing in the wrist joint of a human hand. In our arrangement, applied to a cylindrical soft robot arm, the optical fibres for macrobend sensing originate from the base, extend to the tip of the arm, and then loop back to the base. The connectors that link the fibres to the necessary opto-electronics are all placed at the base of the arm, resulting in a simplified overall design. The ability of this custom macrobend stretch sensor to flexibly adapt its configuration allows preserving the inherent softness and compliance of the robot which it is installed on. The macrobend sensing system is immune to electrical noise and magnetic fields, is safe (because no electricity is needed at the sensing site), and is suitable for modular implementation in multi-link soft continuum robotic arms. The measurable light outputs of the proposed stretch sensor vary due to bend-induced light attenuation (macrobend loss), which is a function of the fibre bend radius as well as the number of repeated turns. The experimental study conducted as part of this research revealed that the chosen bend radius has a far greater impact on the measured light intensity values than the number of turns (if greater than five). Taking into account that the bend radius is the only significantly influencing design parameter, the macrobend stretch sensors were developed to create a practical solution to the pose sensing in soft continuum robot arms. Henceforward, the proposed sensing design was benchmarked against an electromagnetic

  11. Development of a Multi-Arm Mobile Robot for Nuclear Decommissioning Tasks

    Directory of Open Access Journals (Sweden)

    Mohamed J. Bakari

    2008-11-01

    Full Text Available This paper concerns the design of a two-arm mobile delivery platform for application within nuclear decommissioning tasks. The adoption of the human arm as a model of manoeuvrability, scale and dexterity is the starting point for operation of two seven-function arms within the context of nuclear decommissioning tasks, the selection of hardware and its integration, and the development of suitable control methods. The forward and inverse kinematics for the manipulators are derived and the proposed software architecture identified to control the movements of the arm joints and the performance of selected decommissioning tasks. We discuss the adoption of a BROKK demolition machine as a mobile platform and the integration with its hydraulic system to operate the two seven-function manipulators separately. The paper examines the modelling and development of a real-time control method using Proportional-Integral-Derivative (PID and Proportional-Integral-Plus (PIP control algorithms in the host computer with National Instruments functions and tools to control the manipulators and obtain feedback through wireless communication. Finally we consider the application of a third party device, such as a personal mobile phone, and its interface with LabVIEW software in order to operate the robot arms remotely.

  12. Wheelchair-mounted robotic arm to hold and move a communication device - final design.

    Science.gov (United States)

    Barrett, Graham; Kurley, Kyle; Brauchie, Casey; Morton, Scott; Barrett, Steven

    2015-01-01

    At the 51st Rocky Mountain Bioengineering Symposium we presented a preliminary design for a robotic arm to assist an individual living within an assistive technology smart home. The individual controls much of their environment with a Dynavox Maestro communication device. However, the device obstructs the individual’s line of site when navigating about the smart home. A robotic arm was developed to move the communication device in and out of the user’s field of view as desired. The robotic arm is controlled by a conveniently mounted jelly switch. The jelly switch sends control signals to a four state (up, off, down, off) single-axis robotic arm interfaced to a DC motor by high power electronic relays. This paper describes the system, control circuitry, and multiple safety features. The arm will be delivered for use later in 2015.

  13. Using Arm and Hand Gestures to Command Robots during Stealth Operations

    Science.gov (United States)

    Stoica, Adrian; Assad, Chris; Wolf, Michael; You, Ki Sung; Pavone, Marco; Huntsberger, Terry; Iwashita, Yumi

    2012-01-01

    Command of support robots by the warfighter requires intuitive interfaces to quickly communicate high degree-of-freedom (DOF) information while leaving the hands unencumbered. Stealth operations rule out voice commands and vision-based gesture interpretation techniques, as they often entail silent operations at night or in other low visibility conditions. Targeted at using bio-signal inputs to set navigation and manipulation goals for the robot (say, simply by pointing), we developed a system based on an electromyography (EMG) "BioSleeve", a high density sensor array for robust, practical signal collection from forearm muscles. The EMG sensor array data is fused with inertial measurement unit (IMU) data. This paper describes the BioSleeve system and presents initial results of decoding robot commands from the EMG and IMU data using a BioSleeve prototype with up to sixteen bipolar surface EMG sensors. The BioSleeve is demonstrated on the recognition of static hand positions (e.g. palm facing front, fingers upwards) and on dynamic gestures (e.g. hand wave). In preliminary experiments, over 90% correct recognition was achieved on five static and nine dynamic gestures. We use the BioSleeve to control a team of five LANdroid robots in individual and group/squad behaviors. We define a gesture composition mechanism that allows the specification of complex robot behaviors with only a small vocabulary of gestures/commands, and we illustrate it with a set of complex orders.

  14. Concept development of a tendon arm manipulator and anthropomorphic robotic hand

    Science.gov (United States)

    Tolman, C. T.

    1987-01-01

    AMETEK/ORED inhouse research and development efforts leading toward a next-generation robotic manipulator arm and end-effector technology is summarized. Manipulator arm development has been directed toward a multiple-degree-of-freedom, flexible, tendon-driven concept referred to here as a Tendon Arm Manipulator (TAM). End-effector development has been directed toward a three-fingered, dextrous, tendon-driven, anthropomorphic configuration which is referred to as an Anthropomorphic Robotic Hand (ARH). Key technology issues are identified for both concepts.

  15. Position Control Method For Pick And Place Robot Arm For Object Sorting System

    Directory of Open Access Journals (Sweden)

    Khin Moe Myint

    2015-08-01

    Full Text Available The more increase the number of industries in developing countries the more require labourers or workers in that. To reduce the cost of labour force and to increase the manufacturing capacity of industries the advanced robot arms are more needed. The aim of this journal is to eliminate the manual control for object sorting system.Robot arm design in this research uses two joints three links and servo motors to drive. Microcontroller is used to generate required PWM signal for servo motors. In this research the position control of robot arm was designed by using kinematic control methods. There are two types of kinematic control methods which are forward and reverse kinematic methods. In forward kinematic method the input parameters are the joint angles and link length of robot arm and then the output is the position at XYZ coordinate of tool or gripper. In inverse kinematic the input parameters are position at XYZ coordinate of gripper and the link length of robot arm and then the output parameters are the joint angles. So kinematic methods can explain the analytical description of the geometry motion of the manipulator with reference to a robot coordinate system fixed to a frame without consideration of the forces or the moments causing the movements. For sorting system Metal detector is used to detect the metal or non-metal. This position control of pick and place robot arm is fully tested and the result is obtained more precisely.

  16. Computer coordination of limb motion for locomotion of a multiple-armed robot for space assembly

    Science.gov (United States)

    Klein, C. A.; Patterson, M. R.

    1982-01-01

    Consideration is given to a possible robotic system for the construction of large space structures, which may be described as a multiple general purpose arm manipulator vehicle that can walk over the structure under construction to a given site for further work. A description is presented of the locomotion of such a vehicle, modeling its arms in terms of a currently available industrial manipulator. It is noted that for whatever maximum speed of operation is chosen, rapid changes in robot velocity create situations in which already-selected handholds are no longer practical. A step is added to the 'free gait' walking algorithm in order to solve this problem.

  17. A spatial registration method for navigation system combining O-arm with spinal surgery robot

    Science.gov (United States)

    Bai, H.; Song, G. L.; Zhao, Y. W.; Liu, X. Z.; Jiang, Y. X.

    2018-05-01

    The minimally invasive surgery in spinal surgery has become increasingly popular in recent years as it reduces the chances of complications during post-operation. However, the procedure of spinal surgery is complicated and the surgical vision of minimally invasive surgery is limited. In order to increase the quality of percutaneous pedicle screw placement, the O-arm that is a mobile intraoperative imaging system is used to assist surgery. The robot navigation system combined with O-arm is also increasing, with the extensive use of O-arm. One of the major problems in the surgical navigation system is to associate the patient space with the intra-operation image space. This study proposes a spatial registration method of spinal surgical robot navigation system, which uses the O-arm to scan a calibration phantom with metal calibration spheres. First, the metal artifacts were reduced in the CT slices and then the circles in the images based on the moments invariant could be identified. Further, the position of the calibration sphere in the image space was obtained. Moreover, the registration matrix is obtained based on the ICP algorithm. Finally, the position error is calculated to verify the feasibility and accuracy of the registration method.

  18. Maximizing Use of Robot-Arm No. 3 in Da Vinci–Assisted Thoracic Surgery

    Science.gov (United States)

    Kajiwara, Naohiro; Maeda, Junichi; Yoshida, Koichi; Kato, Yasufumi; Hagiwara, Masaru; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2015-01-01

    We have previously reported on the importance of appropriate robot-arm settings and replacement of instrument ports in robot-assisted thoracic surgery, because the thoracic cavity requires a large space to access all lesions in various areas of the thoracic cavity from the apex to the diaphragm and mediastinum and the chest wall.1–3 Moreover, it can be difficult to manipulate the da Vinci Surgical System using only arms No. 1 and No. 2 depending on the tumor location. However, arm No. 3 is usually positioned on the same side as arm No. 2, and sometimes it is only used as an assisting-arm to avoid conflict with other arms (Fig. 1). In this report, we show how robot-arm No. 3 can be used with maximum effectiveness in da Vinci-assisted thoracic surgery. PMID:26011219

  19. End-Effector Position Analysis Using Forward Kinematics For 5 Dof Pravak Robot Arm

    OpenAIRE

    Jolly Atit Shah; S.S. Rattan; B.C. Nakra

    2013-01-01

    Automatic control of the robotic manipulator involves study of kinematics and dynamics as a major issue. This paper involves the kinematic analysis of a Pravak Robot arm which is used for doing successful robotic manipulation task in its workspace. The Pravak Robot Arm is a 5-DOF robot having all the joints revolute. The kinematics problem is defined as the transformation from the Cartesian space to the joint space and vice versa. In this study the Denavit- Hartenberg (D-H) model is used to m...

  20. Lending a helping hand: toward novel assistive robotic arms

    NARCIS (Netherlands)

    Groothuis, Stefan; Stramigioli, Stefano; Carloni, Raffaella

    Assistive robotics is an increasingly popular research field, which has led to a large number of commercial and noncommercial systems aimed at assisting physically impaired or elderly users in the activities of daily living. In this article, we propose five criteria based on robotic arm usage

  1. Reference trajectory tracking for a multi-DOF robot arm

    Directory of Open Access Journals (Sweden)

    Krasňanský Róbert

    2015-12-01

    Full Text Available This paper presents the problem of tracking the generated reference trajectory by the simulation model of a multi-DOF robot arm. The kinematic transformation between task space and joint configuration coordinates is nonlinear and configuration dependent. To obtain the solution of the forward kinematics problem, the homogeneous transformation matrix is used. A solution to the inverse kinematics is a vector of joint configuration coordinates calculated using of pseudoinverse Jacobian technique. These coordinates correspond to a set of task space coordinates. The algorithm is presented which uses iterative solution and is simplified by considering stepper motors in robot arm joints. The reference trajectory in Cartesian coordinate system is generated on-line by the signal generator previously developed in MS Excel. Dynamic Data Exchange communication protocol allows sharing data with Matlab-Simulink. These data represent the reference tracking trajectory of the end effector. Matlab-Simulink software is used to calculate the representative joint rotations. The proposed algorithm is demonstrated experimentally on the model of 7-DOF robot arm system.

  2. Developing and modeling of voice control system for prosthetic robot arm in medical systems

    Directory of Open Access Journals (Sweden)

    Koksal Gundogdu

    2018-04-01

    Full Text Available In parallel with the development of technology, various control methods are also developed. Voice control system is one of these control methods. In this study, an effective modelling upon mathematical models used in the literature is performed, and a voice control system is developed in order to control prosthetic robot arms. The developed control system has been applied on four-jointed RRRR robot arm. Implementation tests were performed on the designed system. As a result of the tests; it has been observed that the technique utilized in our system achieves about 11% more efficient voice recognition than currently used techniques in the literature. With the improved mathematical modelling, it has been shown that voice commands could be effectively used for controlling the prosthetic robot arm. Keywords: Voice recognition model, Voice control, Prosthetic robot arm, Robotic control, Forward kinematic

  3. Desain Proportional Integral Derrivative (Pid) Controller Pada Model Arm Robot Manipulator

    OpenAIRE

    Pratama, Adhityanendra Pandu; Munadi, Munadi

    2014-01-01

    Dalam rangka menuju proses industrialisasi modern di negara Indonesia, harus didukung dengan teknologi yang canggih, contoh nya adalah arm robot manipulator. sebagai pelaku proses produksi sehingga dihasilkan ketepatan,kepresisian, dan kefektifan pada proses produksi. Dengan hal tersebut dibuat sebuah desain kontrol PID pada arm robot manipulator dengan tujuan menghasilkan tingkat presisi dan kestabilan yang lebih baik. Kontroler tersebut didesain, disimulasikan, dan diaplikasikan pada ha...

  4. Investigation of the Impedance Characteristic of Human Arm for Development of Robots to Cooperate with Humans

    Science.gov (United States)

    Rahman, Md. Mozasser; Ikeura, Ryojun; Mizutani, Kazuki

    In the near future many aspects of our lives will be encompassed by tasks performed in cooperation with robots. The application of robots in home automation, agricultural production and medical operations etc. will be indispensable. As a result robots need to be made human-friendly and to execute tasks in cooperation with humans. Control systems for such robots should be designed to work imitating human characteristics. In this study, we have tried to achieve these goals by means of controlling a simple one degree-of-freedom cooperative robot. Firstly, the impedance characteristic of the human arm in a cooperative task is investigated. Then, this characteristic is implemented to control a robot in order to perform cooperative task with humans. A human followed the motion of an object, which is moved through desired trajectories. The motion is actuated by the linear motor of the one degree-of-freedom robot system. Trajectories used in the experiments of this method were minimum jerk (the rate of change of acceleration) trajectory, which was found during human and human cooperative task and optimum for muscle movement. As the muscle is mechanically analogous to a spring-damper system, a simple second-order equation is used as models for the arm dynamics. In the model, we considered mass, stiffness and damping factor. Impedance parameter is calculated from the position and force data obtained from the experiments and based on the “Estimation of Parametric Model”. Investigated impedance characteristic of human arm is then implemented to control a robot, which performed cooperative task with human. It is observed that the proposed control methodology has given human like movements to the robot for cooperating with human.

  5. Two-dimensional myoelectric control of a robotic arm for upper limb amputees

    International Nuclear Information System (INIS)

    Lopez Celani, Natalia M; Soria, Carlos M; Orosco, Eugenio C; Di Sciascio, Fernando A; Valentinuzzi, Max E

    2007-01-01

    Rehabilitation engineering and medicine have become integral and significant parts of health care services, particularly and unfortunately in the last three or four decades, because of wars, terrorism and large number of car accidents. Amputees show a high rate of rejection to wear prosthetic devices, often because of lack of an adequate period of adaptation. A robotic arm may appear as a good preliminary stage. To test the hypothesis, myoelectric signals from two upper limb amputees and from four normal volunteers were fed, via adequate electronic conditioning and using MATLAB, to an industrial robotic arm. Proportional strength control was used for two degrees of freedom (x-y plane) by means of eight signal features of control (four traditional statistics plus energy, integral of the absolute value, Willison's amplitude, waveform length and envelope) for comparison purposes, and selecting the best of them as final reference. Patients easily accepted the system and learned in short time how to operate it. Results were encouraging so that valuable training, before prosthesis is implanted, appears as good feedback; besides, these patients can be hired as specialized operators in semi-automatized industry

  6. Two-dimensional myoelectric control of a robotic arm for upper limb amputees

    Science.gov (United States)

    López Celani, Natalia M.; Soria, Carlos M.; Orosco, Eugenio C.; di Sciascio, Fernando A.; Valentinuzzi, Max E.

    2007-11-01

    Rehabilitation engineering and medicine have become integral and significant parts of health care services, particularly and unfortunately in the last three or four decades, because of wars, terrorism and large number of car accidents. Amputees show a high rate of rejection to wear prosthetic devices, often because of lack of an adequate period of adaptation. A robotic arm may appear as a good preliminary stage. To test the hypothesis, myoelectric signals from two upper limb amputees and from four normal volunteers were fed, via adequate electronic conditioning and using MATLAB, to an industrial robotic arm. Proportional strength control was used for two degrees of freedom (x-y plane) by means of eight signal features of control (four traditional statistics plus energy, integral of the absolute value, Willison's amplitude, waveform length and envelope) for comparison purposes, and selecting the best of them as final reference. Patients easily accepted the system and learned in short time how to operate it. Results were encouraging so that valuable training, before prosthesis is implanted, appears as good feedback; besides, these patients can be hired as specialized operators in semi-automatized industry.

  7. Coordination of dual robot arms using kinematic redundancy

    Science.gov (United States)

    Suh, Il Hong; Shin, Kang G.

    1988-01-01

    A method is developed to coordinate the motion of dual robot arms carrying a solid object, where the first robot (leader) grasps one end of the object rigidly and the second robot (follower) is allowed to change its grasping position at the other end of the object along the object surface while supporting the object. It is shown that this flexible grasping is equivalent to the addition of one more degree of freedom (dof), giving the follower more maneuvering capabilities. In particular, motion commands for the follower are generated by using kinematic redundancy. To show the utility and power of the method, an example system with two PUMA 560 robots carrying a beam is analyzed.

  8. Achievement report for fiscal 2000 on operational research of human cooperative and coexisting (humanoid) robot system. Operational research of humanoid robot system; 2000 nendo ningen kyocho kyozongata robot system un'yo kenkyu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    This paper reports the achievements in fiscal 2000 in the operational research of humanoid robot system. Carrying out the development smoothly and efficiently requires accumulation of the operational know-how in both of the periodical check and maintenance and the aspects of hard and software to maintain the functions and performances of the robot platform having been developed in the previous fiscal year. Checks were given on fitting of the fasteners and connectors, batteries, and sensors. Operations were confirmed and adjusted on the liquid crystal projector of the surrounded visual display system for remotely controlled operation, polarization filters, screens, reflector mirrors, and wide viewing angle cameras. Verifications were made on fitting of the arm operation force sensing and presenting system, checks on the mechanical components, and operation of the driving system, whereas no change has been found in the operation for the period of one year, and sufficient performance was identified for the remote robot operation. The virtual robot platform has presented no crash and impediments during erroneous use in the disks of the dynamics simulator and the distributed network processing system. (NEDO)

  9. Inverse kinematics of OWI-535 robotic arm

    OpenAIRE

    DEBENEC, PRIMOŽ

    2015-01-01

    The thesis aims to calculate the inverse kinematics for the OWI-535 robotic arm. The calculation of the inverse kinematics determines the joint parameters that provide the right pose of the end effector. The pose consists of the position and orientation, however, we will focus only on the second one. Due to arm limitations, we have created our own type of the calculation of the inverse kinematics. At first we have derived it only theoretically, and then we have transferred the derivation into...

  10. Robotic digital subtraction angiography systems within the hybrid operating room.

    Science.gov (United States)

    Murayama, Yuichi; Irie, Koreaki; Saguchi, Takayuki; Ishibashi, Toshihiro; Ebara, Masaki; Nagashima, Hiroyasu; Isoshima, Akira; Arakawa, Hideki; Takao, Hiroyuki; Ohashi, Hiroki; Joki, Tatsuhiro; Kato, Masataka; Tani, Satoshi; Ikeuchi, Satoshi; Abe, Toshiaki

    2011-05-01

    Fully equipped high-end digital subtraction angiography (DSA) within the operating room (OR) environment has emerged as a new trend in the fields of neurosurgery and vascular surgery. To describe initial clinical experience with a robotic DSA system in the hybrid OR. A newly designed robotic DSA system (Artis zeego; Siemens AG, Forchheim, Germany) was installed in the hybrid OR. The system consists of a multiaxis robotic C arm and surgical OR table. In addition to conventional neuroendovascular procedures, the system was used as an intraoperative imaging tool for various neurosurgical procedures such as aneurysm clipping and spine instrumentation. Five hundred one neurosurgical procedures were successfully conducted in the hybrid OR with the robotic DSA. During surgical procedures such as aneurysm clipping and arteriovenous fistula treatment, intraoperative 2-/3-dimensional angiography and C-arm-based computed tomographic images (DynaCT) were easily performed without moving the OR table. Newly developed virtual navigation software (syngo iGuide; Siemens AG) can be used in frameless navigation and in access to deep-seated intracranial lesions or needle placement. This newly developed robotic DSA system provides safe and precise treatment in the fields of endovascular treatment and neurosurgery.

  11. Using Human Gestures and Generic Skills to Instruct a Mobile Robot Arm in a Feeder Filling Scenario

    DEFF Research Database (Denmark)

    Pedersen, Mikkel Rath; Høilund, Carsten; Krüger, Volker

    2012-01-01

    Mobile robots that have the ability to cooperate with humans are able to provide new possibilities to manufac- turing industries. In this paper, we discuss our mobile robot arm that a) can provide assistance at different locations in a factory and b) that can be programmed using complex human...... actions such as pointing in Take this object. In this paper, we discuss the use of the mobile robot for a feeding scenario where a human operator specifies the parts and the feeders through pointing gestures. The system is partially built using generic robotic skills. Through extensive experiments, we...

  12. Position Based Visual Servoing control of a Wheelchair Mounter Robotic Arm using Parallel Tracking and Mapping of task objects

    Directory of Open Access Journals (Sweden)

    Alessandro Palla

    2017-05-01

    Full Text Available In the last few years power wheelchairs have been becoming the only device able to provide autonomy and independence to people with motor skill impairments. In particular, many power wheelchairs feature robotic arms for gesture emulation, like the interaction with objects. However, complex robotic arms often require a joystic to be controlled; this feature make the arm hard to be controlled by impaired users. Paradoxically, if the user were able to proficiently control such devices, he would not need them. For that reason, this paper presents a highly autonomous robotic arm, designed in order to minimize the effort necessary for the control of the arm. In order to do that, the arm feature an easy to use human - machine interface and is controlled by Computer Vison algorithm, implementing a Position Based Visual Servoing (PBVS control. It was realized by extracting features by the camera and fusing them with the distance from the target, obtained by a proximity sensor. The Parallel Tracking and Mapping (PTAM algorithm was used to find the 3D position of the task object in the camera reference system. The visual servoing algorithm was implemented in an embedded platform, in real time. Each part of the control loop was developed in Robotic Operative System (ROS Environment, which allows to implement the previous algorithms as different nodes. Theoretical analysis, simulations and in system measurements proved the effectiveness of the proposed solution.

  13. Grasping and Placing Operation for Labware Transportation in Life Science Laboratories using Mobile Robots

    Directory of Open Access Journals (Sweden)

    Mohammed Myasar Ali

    2017-07-01

    Full Text Available In automated working environments, mobile robots can be used for different purposes such as material handling, domestic services, and objects transportation. This work presents a grasping and placing operation for multiple labware and tube racks in life science laboratories using the H20 mobile robots. The H20 robot has dual arms where each arm consists of 6 revolute joints with 6-DOF and 2-DOF grippers. The labware, which have to be manipulated and transported, contain chemical and biological components. Therefore, an accurate approach for object recognition and position estimation is required. The recognition and pose estimation of the desired objects are very essential to guide the robotic arm in the manipulation tasks. In this work, the problem statement of H20 transportation system with the proposed methodology are presented. Different strategies (visual and non-visual of labware manipulation using mobile robots are described. The H20 robot is equipped with a Kinect V2 sensor to identify and estimate the position of the target. The local features recognition based on SURF algorithm (Speeded-Up Robust Features is used. The recognition process is performed for the required labware and holder to perform the grasping and placing operation. A strategy is proposed to find the required holder and to check its emptiness for the placing tasks. Different styles of grippers and labware containers are used to manipulate different weights of labware and to realize a safe transportation. The parts of mobile robot transportation system are communicated with each other using Asynchronous socket Channels.

  14. Trajectory control of an articulated robot with a parallel drive arm based on splines under tension

    Science.gov (United States)

    Yi, Seung-Jong

    Today's industrial robots controlled by mini/micro computers are basically simple positioning devices. The positioning accuracy depends on the mathematical description of the robot configuration to place the end-effector at the desired position and orientation within the workspace and on following the specified path which requires the trajectory planner. In addition, the consideration of joint velocity, acceleration, and jerk trajectories are essential for trajectory planning of industrial robots to obtain smooth operation. The newly designed 6 DOF articulated robot with a parallel drive arm mechanism which permits the joint actuators to be placed in the same horizontal line to reduce the arm inertia and to increase load capacity and stiffness is selected. First, the forward kinematic and inverse kinematic problems are examined. The forward kinematic equations are successfully derived based on Denavit-Hartenberg notation with independent joint angle constraints. The inverse kinematic problems are solved using the arm-wrist partitioned approach with independent joint angle constraints. Three types of curve fitting methods used in trajectory planning, i.e., certain degree polynomial functions, cubic spline functions, and cubic spline functions under tension, are compared to select the best possible method to satisfy both smooth joint trajectories and positioning accuracy for a robot trajectory planner. Cubic spline functions under tension is the method selected for the new trajectory planner. This method is implemented for a 6 DOF articulated robot with a parallel drive arm mechanism to improve the smoothness of the joint trajectories and the positioning accuracy of the manipulator. Also, this approach is compared with existing trajectory planners, 4-3-4 polynomials and cubic spline functions, via circular arc motion simulations. The new trajectory planner using cubic spline functions under tension is implemented into the microprocessor based robot controller and

  15. An artificial flexible robot arm based on pneumatic muscle actuators

    Directory of Open Access Journals (Sweden)

    Renn Jyh-Chyang

    2017-01-01

    Full Text Available The purpose of this paper is to develop a novel human-friendly artificial flexible robot arm using four parallel-connected pneumatic muscle actuators (PMAs. The PMA is a flexible silicone rubber actuator which has some behaviors nearest to the real biological muscle including translational and rotational motions. An inverse kinematic model for the motion control is also developed. Finally, from experiment results, it is proved that not only the axial contraction control of a single PMA but also the attitude control of the whole pneumatic flexible robot arm using PID controller are satisfactory.

  16. Method of Grasping Control by Computing Internal and External Impedances for Two Robot Fingers, and Its Application to Admittance Control of a Robot Hand-Arm System

    Directory of Open Access Journals (Sweden)

    Jian Huang

    2015-08-01

    Full Text Available Impedance control is an important technology used in the grasping control of a robot hand. Numerous studies related to grasping algorithms have been reported in recent years, with the contact force between robot fingers and the object to be grasped being primarily discussed in most cases. Generally, a coupling effect occurs between the internal loop of the grasping operation and the external loop of the interaction with the environment when a multi-fingered robot hand is used to complete a contact task. Therefore, a robot hand cannot hold an object using a large external force to complete a wide range of tasks by applying the conventional method. In this paper, the coupling of the internal/external forces occurring in grasping operations using multiple fingers is analysed. Then, improved impedance control based on the previous method is proposed as an effective tool to solve the problem of grasping failure caused by single-finger contact. Furthermore, a method for applying the improved grasping algorithm to the admittance control of a robot hand-arm system is also proposed. The proposed method divides the impedance effect into the grasping control of the hand and the cooperative control of the arm, so that expanding the task space and increasing the flexibility of impedance adjustment can be achieved. Experiments were conducted to demonstrate the effectiveness of the proposed method.

  17. SpaceWire- Based Control System Architecture for the Lightweight Advanced Robotic Arm Demonstrator [LARAD

    Science.gov (United States)

    Rucinski, Marek; Coates, Adam; Montano, Giuseppe; Allouis, Elie; Jameux, David

    2015-09-01

    The Lightweight Advanced Robotic Arm Demonstrator (LARAD) is a state-of-the-art, two-meter long robotic arm for planetary surface exploration currently being developed by a UK consortium led by Airbus Defence and Space Ltd under contract to the UK Space Agency (CREST-2 programme). LARAD has a modular design, which allows for experimentation with different electronics and control software. The control system architecture includes the on-board computer, control software and firmware, and the communication infrastructure (e.g. data links, switches) connecting on-board computer(s), sensors, actuators and the end-effector. The purpose of the control system is to operate the arm according to pre-defined performance requirements, monitoring its behaviour in real-time and performing safing/recovery actions in case of faults. This paper reports on the results of a recent study about the feasibility of the development and integration of a novel control system architecture for LARAD fully based on the SpaceWire protocol. The current control system architecture is based on the combination of two communication protocols, Ethernet and CAN. The new SpaceWire-based control system will allow for improved monitoring and telecommanding performance thanks to higher communication data rate, allowing for the adoption of advanced control schemes, potentially based on multiple vision sensors, and for the handling of sophisticated end-effectors that require fine control, such as science payloads or robotic hands.

  18. Deft Control Software (DCS) for Remote Robotic Operations with Underlying Structure, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — BluHaptics proposes Deft Control Software (DCS), which utilizes machine learning to enable intuitive and efficient control of robotic arms in remote operations with...

  19. Adaptive training algorithm for robot-assisted upper-arm rehabilitation, applicable to individualised and therapeutic human-robot interaction.

    Science.gov (United States)

    Chemuturi, Radhika; Amirabdollahian, Farshid; Dautenhahn, Kerstin

    2013-09-28

    Rehabilitation robotics is progressing towards developing robots that can be used as advanced tools to augment the role of a therapist. These robots are capable of not only offering more frequent and more accessible therapies but also providing new insights into treatment effectiveness based on their ability to measure interaction parameters. A requirement for having more advanced therapies is to identify how robots can 'adapt' to each individual's needs at different stages of recovery. Hence, our research focused on developing an adaptive interface for the GENTLE/A rehabilitation system. The interface was based on a lead-lag performance model utilising the interaction between the human and the robot. The goal of the present study was to test the adaptability of the GENTLE/A system to the performance of the user. Point-to-point movements were executed using the HapticMaster (HM) robotic arm, the main component of the GENTLE/A rehabilitation system. The points were displayed as balls on the screen and some of the points also had a real object, providing a test-bed for the human-robot interaction (HRI) experiment. The HM was operated in various modes to test the adaptability of the GENTLE/A system based on the leading/lagging performance of the user. Thirty-two healthy participants took part in the experiment comprising of a training phase followed by the actual-performance phase. The leading or lagging role of the participant could be used successfully to adjust the duration required by that participant to execute point-to-point movements, in various modes of robot operation and under various conditions. The adaptability of the GENTLE/A system was clearly evident from the durations recorded. The regression results showed that the participants required lower execution times with the help from a real object when compared to just a virtual object. The 'reaching away' movements were longer to execute when compared to the 'returning towards' movements irrespective of the

  20. Using a Robotic Arm to Evaluate the Programming Ability of K-12 Educators

    Directory of Open Access Journals (Sweden)

    Antoinette Bruciati

    2006-12-01

    Full Text Available This usability study measured the ability of educators to master advanced computer programming concepts through the OWI Robotic Arm Trainer and PC Interface. Research findings revealed that the lack of prior computer programming experience did not impact the ability of each participant to successfully program his/her robotic arm. However, the absence of a detailed instructional manual detracted from the product

  1. Coordinated trajectory planning of dual-arm space robot using constrained particle swarm optimization

    Science.gov (United States)

    Wang, Mingming; Luo, Jianjun; Yuan, Jianping; Walter, Ulrich

    2018-05-01

    Application of the multi-arm space robot will be more effective than single arm especially when the target is tumbling. This paper investigates the application of particle swarm optimization (PSO) strategy to coordinated trajectory planning of the dual-arm space robot in free-floating mode. In order to overcome the dynamics singularities issue, the direct kinematics equations in conjunction with constrained PSO are employed for coordinated trajectory planning of dual-arm space robot. The joint trajectories are parametrized with Bézier curve to simplify the calculation. Constrained PSO scheme with adaptive inertia weight is implemented to find the optimal solution of joint trajectories while specific objectives and imposed constraints are satisfied. The proposed method is not sensitive to the singularity issue due to the application of forward kinematic equations. Simulation results are presented for coordinated trajectory planning of two kinematically redundant manipulators mounted on a free-floating spacecraft and demonstrate the effectiveness of the proposed method.

  2. Optimum Design of Multi-Function Robot Arm Gripper for Varying Shape Green Product

    Directory of Open Access Journals (Sweden)

    Razali Zol Bahri

    2016-01-01

    Full Text Available The project focuses on thorough experimentally studies of the optimum design of Multi-function Robot Arm Gripper for varying shape green product. The purpose of this project is to design a few of robot arm gripper for multi-functionally grip a green product with varying shape. The main character of the gripper is that it can automated adjust its finger to suit with the shape of the product. An optimum design of multi-function robot arm gripper is verified through experimental study. The expected result is a series of analytical results on the proposal of gripper design and material that will be selected for the gripper. The analysis of the gripper design proposal by using ANSYS and CATIA software is described in detail in this paper.

  3. Digital Hardware Realization of Forward and Inverse Kinematics for a Five-Axis Articulated Robot Arm

    Directory of Open Access Journals (Sweden)

    Bui Thi Hai Linh

    2015-01-01

    Full Text Available When robot arm performs a motion control, it needs to calculate a complicated algorithm of forward and inverse kinematics which consumes much CPU time and certainty slows down the motion speed of robot arm. Therefore, to solve this issue, the development of a hardware realization of forward and inverse kinematics for an articulated robot arm is investigated. In this paper, the formulation of the forward and inverse kinematics for a five-axis articulated robot arm is derived firstly. Then, the computations algorithm and its hardware implementation are described. Further, very high speed integrated circuits hardware description language (VHDL is applied to describe the overall hardware behavior of forward and inverse kinematics. Additionally, finite state machine (FSM is applied for reducing the hardware resource usage. Finally, for verifying the correctness of forward and inverse kinematics for the five-axis articulated robot arm, a cosimulation work is constructed by ModelSim and Simulink. The hardware of the forward and inverse kinematics is run by ModelSim and a test bench which generates stimulus to ModelSim and displays the output response is taken in Simulink. Under this design, the forward and inverse kinematics algorithms can be completed within one microsecond.

  4. Robotic Arm Control Algorithm Based on Stereo Vision Using RoboRealm Vision

    Directory of Open Access Journals (Sweden)

    SZABO, R.

    2015-05-01

    Full Text Available The goal of this paper is to present a stereo computer vision algorithm intended to control a robotic arm. Specific points on the robot joints are marked and recognized in the software. Using a dedicated set of mathematic equations, the movement of the robot is continuously computed and monitored with webcams. Positioning error is finally analyzed.

  5. MOVEMENT SIMULATION OF THREE ARMED ROBOT BY BEING USED AutoLISP

    Directory of Open Access Journals (Sweden)

    Mustafa BOZDEMİR

    2000-01-01

    Full Text Available Development of a suitable robot for desired aim and duty is very important for design enginers. On the other hand, designed robots may be unsuccesful in functioning inspite of many efforts. For this reason, before the production of considered robot systems, having prepared a simulation program, investigation of work field, getting done path plan and mistakes could be eliminated before robot production. In this study, movement simulation of a three armed robot has been realized by using AutoLIPS programing language which is supplied with AutoCAD. Analytical and matrix solution methods have been used in simulation equations.

  6. Constraint optimization model of a scheduling problem for a robotic arm in automatic systems

    DEFF Research Database (Denmark)

    Kristiansen, Ewa; Smith, Stephen F.; Kristiansen, Morten

    2014-01-01

    are characteristics of the painting process application itself. Unlike spot-welding, painting tasks require movement of the entire robot arm. In addition to minimizing intertask duration, the scheduler must strive to maximize painting quality and the problem is formulated as a multi-objective optimization problem....... The scheduling model is implemented as a stand-alone module using constraint programming, and integrated with a larger automatic system. The results of a number of simulation experiments with simple parts are reported, both to characterize the functionality of the scheduler and to illustrate the operation...... of the entire software system for automatic generation of robot programs for painting....

  7. Lower Robotic Arm Assembly Having a Plurality of Tendon Driven Digits

    Science.gov (United States)

    Guo, Raymond (Inventor); Bridgwater, Lyndon (Inventor); Nguyen, Vienny (Inventor); Radford, Nicolaus A. (Inventor)

    2016-01-01

    A lower robotic arm includes a base structure, a plurality of digits, and a plurality of tendons. The digits each include first, second, third, and fourth phalanges. Each digit is operatively attached to the base structure at the respective first phalange. A first joint operatively connects the first and second phalange to define a first axis, a second operatively connects the second and third phalange to define a second axis, and a third joint operatively connects the third and fourth phalange to define a third axis, such that the phalanges are selectively rotatable relative to the adjacent phalange, about the respective axis. The tendons are operatively connected to a respective one of the fourth phalanges. Each tendon selectively applies a first torque to the respective fourth phalange to urge the respective phalanges to rotate in a first direction about the respective axes.

  8. Design optimization on the drive train of a light-weight robotic arm

    DEFF Research Database (Denmark)

    Zhou, Lelai; Bai, Shaoping; Hansen, Michael Rygaard

    2011-01-01

    A drive train optimization method for design of light-weight robots is proposed. Optimal selections of motors and gearboxes from a limited catalog of commercially available components are done simultaneously for all joints of a robotic arm. Characteristics of the motor and gearbox, including gear...... ratio, gear inertia, motor inertia, and gear efficiency, are considered in the drive train modeling. A co-simulation method is developed for dynamic simulation of the arm. A design example is included to demonstrate the proposed design optimization method....

  9. Some mechanical design aspects of the European Robotic Arm

    Science.gov (United States)

    Lambooy, Peter J.; Mandersloot, Wart M.; Bentall, Richard H.

    1995-01-01

    The European Robotic Arm (ERA) is a contribution to the Russian Segment of the International Space Station Alpha. It will start operating on the Russian Segment during the assembly phase. ERA is designed and produced by a large industrial consortium spread over Europe with Fokker Space & Systems as prime contractor. In this paper, we will describe some of the overall design aspects and focus on the development of several mechanisms within ERA. The operation of ERA during the approach of its end effector towards the grapple interface and the grapple operation is discussed, with a focus on mechanisms. This includes the geometry of the end effector leading edge, which is carefully designed to provide the correct and complete tactile information to a torque-force sensor (TFS). The data from this TFS are used to steer the arm such that forces and moments are kept below 20 N and 20 N.m respectively during the grappling operation. Two hardware models of the end effector are built. The problems encountered are described as well as their solutions. The joints in the wrists and the elbow initially used a harmonic drive lubricated by MoS2. During development testing, this combination showed an insufficient lifetime in air to survive the acceptance test program. The switch-over to a system comprising planetary gearboxes with grease lubrication is described. From these development efforts, conclusions are drawn and recommendations are given for the design of complex space mechanisms.

  10. A New Artificial Neural Network Approach in Solving Inverse Kinematics of Robotic Arm (Denso VP6242)

    Science.gov (United States)

    Dülger, L. Canan; Kapucu, Sadettin

    2016-01-01

    This paper presents a novel inverse kinematics solution for robotic arm based on artificial neural network (ANN) architecture. The motion of robotic arm is controlled by the kinematics of ANN. A new artificial neural network approach for inverse kinematics is proposed. The novelty of the proposed ANN is the inclusion of the feedback of current joint angles configuration of robotic arm as well as the desired position and orientation in the input pattern of neural network, while the traditional ANN has only the desired position and orientation of the end effector in the input pattern of neural network. In this paper, a six DOF Denso robotic arm with a gripper is controlled by ANN. The comprehensive experimental results proved the applicability and the efficiency of the proposed approach in robotic motion control. The inclusion of current configuration of joint angles in ANN significantly increased the accuracy of ANN estimation of the joint angles output. The new controller design has advantages over the existing techniques for minimizing the position error in unconventional tasks and increasing the accuracy of ANN in estimation of robot's joint angles. PMID:27610129

  11. A New Artificial Neural Network Approach in Solving Inverse Kinematics of Robotic Arm (Denso VP6242).

    Science.gov (United States)

    Almusawi, Ahmed R J; Dülger, L Canan; Kapucu, Sadettin

    2016-01-01

    This paper presents a novel inverse kinematics solution for robotic arm based on artificial neural network (ANN) architecture. The motion of robotic arm is controlled by the kinematics of ANN. A new artificial neural network approach for inverse kinematics is proposed. The novelty of the proposed ANN is the inclusion of the feedback of current joint angles configuration of robotic arm as well as the desired position and orientation in the input pattern of neural network, while the traditional ANN has only the desired position and orientation of the end effector in the input pattern of neural network. In this paper, a six DOF Denso robotic arm with a gripper is controlled by ANN. The comprehensive experimental results proved the applicability and the efficiency of the proposed approach in robotic motion control. The inclusion of current configuration of joint angles in ANN significantly increased the accuracy of ANN estimation of the joint angles output. The new controller design has advantages over the existing techniques for minimizing the position error in unconventional tasks and increasing the accuracy of ANN in estimation of robot's joint angles.

  12. Imaging-guided thoracoscopic resection of a ground-glass opacity lesion in a hybrid operating room equipped with a robotic C-arm CT system.

    Science.gov (United States)

    Hsieh, Chen-Ping; Hsieh, Ming-Ju; Fang, Hsin-Yueh; Chao, Yin-Kai

    2017-05-01

    The intraoperative identification of small pulmonary nodules through video-assisted thoracoscopic surgery remains challenging. Although preoperative CT-guided nodule localization is commonly used to detect tumors during video-assisted thoracoscopic surgery (VATS), this approach carries inherent risks. We report the case of a patient with stage I lung cancer presenting as an area of ground-glass opacity (GGO) in the right upper pulmonary lobe. He successfully underwent a single-stage, CT-guided localization and removal of the pulmonary nodule within a hybrid operating room (OR) equipped with a robotic C-arm.

  13. High effective inverse dynamics modelling for dual-arm robot

    Science.gov (United States)

    Shen, Haoyu; Liu, Yanli; Wu, Hongtao

    2018-05-01

    To deal with the problem of inverse dynamics modelling for dual arm robot, a recursive inverse dynamics modelling method based on decoupled natural orthogonal complement is presented. In this model, the concepts and methods of Decoupled Natural Orthogonal Complement matrices are used to eliminate the constraint forces in the Newton-Euler kinematic equations, and the screws is used to express the kinematic and dynamics variables. On this basis, the paper has developed a special simulation program with symbol software of Mathematica and conducted a simulation research on the a dual-arm robot. Simulation results show that the proposed method based on decoupled natural orthogonal complement can save an enormous amount of CPU time that was spent in computing compared with the recursive Newton-Euler kinematic equations and the results is correct and reasonable, which can verify the reliability and efficiency of the method.

  14. Managing the backscatter component from the robotic arm of an a-Si EPID

    International Nuclear Information System (INIS)

    Lee, C.G.; Menk, F.; Greer, P.B.

    2010-01-01

    Full text: Backscatter from the robotic arm mechanism of an a-Si EPID in IMRT images was examined. Images corrected with a conventional flood field (FF) containing a backscatter component (BSC) from the robotic ann were compared with a BSC-free FF. A Yarian 21 EX linac (6 MV, 18 MV) was used. All images were acquired with two aS500 EPIDs, one R-arm and one E-arm. The BSC of an EPID image is the ratio of an image acquired with the EPID attached to the arm then detaching the arm from the EPID and acquiring the same image. A range of square field sizes from 2.5 x 2.5 cm to 27.5 x 27.5 cm were acquired and the BSC analyzed. The BSC of the FFs were also measured. A series of IMRT fields were acquired. Each field was corrected with a conventional FF and compared with a BSC-free FF. Figure I shows the magnitude of the BSC from each arm in the inplane for a 6 x beam. Square fields above 16 x l6 cm (R-arm) and lO x 10 cm (E-arm) benefited from a conventional FF as it tended to cancel out the BSC in the acquired square field. The opposite was observed for smaller field sizes. A gamma analysis of the IMRT fields showed a FF correction containing a BSC reduces the effect of the arm in the final image. IMRT EPID images using conventional FFs have been shown to be less affected by backscatter from the robotic arm compared to BSC-free flood fields. (author)

  15. Novel Design of a Soft Lightweight Pneumatic Continuum Robot Arm with Decoupled Variable Stiffness and Positioning.

    Science.gov (United States)

    Giannaccini, Maria Elena; Xiang, Chaoqun; Atyabi, Adham; Theodoridis, Theo; Nefti-Meziani, Samia; Davis, Steve

    2018-02-01

    Soft robot arms possess unique capabilities when it comes to adaptability, flexibility, and dexterity. In addition, soft systems that are pneumatically actuated can claim high power-to-weight ratio. One of the main drawbacks of pneumatically actuated soft arms is that their stiffness cannot be varied independently from their end-effector position in space. The novel robot arm physical design presented in this article successfully decouples its end-effector positioning from its stiffness. An experimental characterization of this ability is coupled with a mathematical analysis. The arm combines the light weight, high payload to weight ratio and robustness of pneumatic actuation with the adaptability and versatility of variable stiffness. Light weight is a vital component of the inherent safety approach to physical human-robot interaction. To characterize the arm, a neural network analysis of the curvature of the arm for different input pressures is performed. The curvature-pressure relationship is also characterized experimentally.

  16. Right-Arm Robotic-Aided-Therapy with the Light-Exoskeleton: A General Overview

    Science.gov (United States)

    Lugo-Villeda, Luis I.; Frisoli, Antonio; Sotgiu, Edoardo; Greco, Giovanni; Bergamasco, Massimo

    Rehabilitation robotics applications and their developments have been spreading out as consequences of the actual needs in the human activities of daily living (ADL). Exoskeletons for rehabilitation are one of them, whose intrinsic characteristics are quite useful for applications where repetitive, robustness and accurate performance are a must. As a part of robotic-mediated-rehabilitation programme into the worldwide, the exoskeletons are trying to improve the ADL of disable people through the fusion of several disciplines that lets to expand the capabilities of wearing a powered robotic exoskeletal device for rehabilitation tasks. This fact deserves to present this contribution from a general scope point of view, i.e., the technologies integration and its associated knowledge. So far, the Light-Exoskeleton which is intended for human arm rehabilitation in post-stroke patients is introduced. Preliminary experimental results as well as the involved stages about the system show the capabilities of using a robotic-constrained-rehabilitation for human arm.

  17. Reach and grasp by people with tetraplegia using a neurally controlled robotic arm

    Science.gov (United States)

    Hochberg, Leigh R.; Bacher, Daniel; Jarosiewicz, Beata; Masse, Nicolas Y.; Simeral, John D.; Vogel, Joern; Haddadin, Sami; Liu, Jie; Cash, Sydney S.; van der Smagt, Patrick; Donoghue, John P.

    2012-01-01

    Paralysis following spinal cord injury (SCI), brainstem stroke, amyotrophic lateral sclerosis (ALS) and other disorders can disconnect the brain from the body, eliminating the ability to carry out volitional movements. A neural interface system (NIS)1–5 could restore mobility and independence for people with paralysis by translating neuronal activity directly into control signals for assistive devices. We have previously shown that people with longstanding tetraplegia can use an NIS to move and click a computer cursor and to control physical devices6–8. Able-bodied monkeys have used an NIS to control a robotic arm9, but it is unknown whether people with profound upper extremity paralysis or limb loss could use cortical neuronal ensemble signals to direct useful arm actions. Here, we demonstrate the ability of two people with long-standing tetraplegia to use NIS-based control of a robotic arm to perform three-dimensional reach and grasp movements. Participants controlled the arm over a broad space without explicit training, using signals decoded from a small, local population of motor cortex (MI) neurons recorded from a 96-channel microelectrode array. One of the study participants, implanted with the sensor five years earlier, also used a robotic arm to drink coffee from a bottle. While robotic reach and grasp actions were not as fast or accurate as those of an able-bodied person, our results demonstrate the feasibility for people with tetraplegia, years after CNS injury, to recreate useful multidimensional control of complex devices directly from a small sample of neural signals. PMID:22596161

  18. Development of a multisensory arm for process monitoring in Robot Assisted Polishing

    DEFF Research Database (Denmark)

    Pilny, Lukas; Dalla Costa, Giuseppe; Bissacco, Giuliano

    2015-01-01

    A multisensory polishing arm with integrated three component force sensor, a miniature acoustic emission (AE) sensor and an accelerometer was developed for process monitoring in Robot Assisted Polishing (RAP) process. The arm design was optimized for integration of a force and an AE sensor. The f...

  19. A New Artificial Neural Network Approach in Solving Inverse Kinematics of Robotic Arm (Denso VP6242

    Directory of Open Access Journals (Sweden)

    Ahmed R. J. Almusawi

    2016-01-01

    Full Text Available This paper presents a novel inverse kinematics solution for robotic arm based on artificial neural network (ANN architecture. The motion of robotic arm is controlled by the kinematics of ANN. A new artificial neural network approach for inverse kinematics is proposed. The novelty of the proposed ANN is the inclusion of the feedback of current joint angles configuration of robotic arm as well as the desired position and orientation in the input pattern of neural network, while the traditional ANN has only the desired position and orientation of the end effector in the input pattern of neural network. In this paper, a six DOF Denso robotic arm with a gripper is controlled by ANN. The comprehensive experimental results proved the applicability and the efficiency of the proposed approach in robotic motion control. The inclusion of current configuration of joint angles in ANN significantly increased the accuracy of ANN estimation of the joint angles output. The new controller design has advantages over the existing techniques for minimizing the position error in unconventional tasks and increasing the accuracy of ANN in estimation of robot’s joint angles.

  20. Design a Fuzzy Logic Controller for a Rotary Flexible Joint Robotic Arm

    Directory of Open Access Journals (Sweden)

    Jalani Jamaludin

    2018-01-01

    Full Text Available The purpose of this research is to design a fuzzy logic feedback controller (FLC in order to control a desired tip angle position a rotary flexible joint robotic arm. The FLC is also employed to dampen the vibration emanated from a rotary flexible joint robotic arm when reaching a desired tip angle position. The performance of FLC is tested in simulation and experiment. It is found that the FLC is successfully designed, applied and tested. The results show that fuzzy logic controller performed satisfactorily control a desired tip angle position and reduce the oscillations.

  1. A robotic C-arm cone beam CT system for image-guided proton therapy: design and performance.

    Science.gov (United States)

    Hua, Chiaho; Yao, Weiguang; Kidani, Takao; Tomida, Kazuo; Ozawa, Saori; Nishimura, Takenori; Fujisawa, Tatsuya; Shinagawa, Ryousuke; Merchant, Thomas E

    2017-11-01

    A ceiling-mounted robotic C-arm cone beam CT (CBCT) system was developed for use with a 190° proton gantry system and a 6-degree-of-freedom robotic patient positioner. We report on the mechanical design, system accuracy, image quality, image guidance accuracy, imaging dose, workflow, safety and collision-avoidance. The robotic CBCT system couples a rotating C-ring to the C-arm concentrically with a kV X-ray tube and a flat-panel imager mounted to the C-ring. CBCT images are acquired with flex correction and maximally 360° rotation for a 53 cm field of view. The system was designed for clinical use with three imaging locations. Anthropomorphic phantoms were imaged to evaluate the image guidance accuracy. The position accuracy and repeatability of the robotic C-arm was high (robotic CBCT system provides high-accuracy volumetric image guidance for proton therapy. Advances in knowledge: Ceiling-mounted robotic CBCT provides a viable option than CT on-rails for partial gantry and fixed-beam proton systems with the added advantage of acquiring images at the treatment isocentre.

  2. The Microsoft Visual Studio Software Development For 5 DOF Nuclear Malaysia Robot Arm V2 Control System

    International Nuclear Information System (INIS)

    Mohd Zaid Hassan; Anwar Abdul Rahman; Azraf Azman; Mohd Rizal Mamat; Mohd Arif Hamzah

    2014-01-01

    This paper presents the Microsoft visual studio development for 5DOF Nuclear Malaysia Robot Arm V2 control system. The kinematics analysis is the study of the relationship between the individual joints of robot manipulator, the position and orientation of the end-effector. The Denavit-Hartenberg (DH) model is used to model the robot links and joints. Both forward and inverse kinematic are presented. The simulation software has been developed by using Microsoft visual studio to solve the robot arms kinematic behavior. (author)

  3. Operation of an ITER relevant inspection robot on Tore Supra tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Gargiulo, Laurent [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France)], E-mail: laurent.gargiulo@cea.fr; Bayetti, Pascal; Bruno, Vincent; Hatchressian, Jean-Claude; Hernandez, Caroline; Houry, Michael [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Keller, Delphine [CEA, LIST, Service de Robotique Interactive, F-92265 Fontenay aux Roses (France); Martins, Jean-Pierre [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Measson, Yvan; Perrot, Yann [CEA, LIST, Service de Robotique Interactive, F-92265 Fontenay aux Roses (France); Samaille, Frank [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France)

    2009-06-15

    Robotic operations are one of the major maintenance challenges for ITER and future fusion reactors. CEA has developed a multipurpose carrier able to realize deployments in the plasma vessel without breaking the Ultra High Vacuum (UHV) and temperature conditioning. A 6 years R and D programme was jointly conducted by CEA-LIST Interactive Robotics Unit and the Institute for Magnetic Fusion Research (IRFM) in order to demonstrate the feasibility and reliability of an in-vessel inspection robot relevant to ITER requirements. The Articulated Inspection Arm robot (AIA) is an 8-m long multilink carrier with a payload up to 10 kg operable between plasma under tokamak conditioning environment; its geometry allows a complete close inspection of Plasma Facing Components (PFCs) of the Tore Supra vessel. Different tools are being developed by CEA to be plugged at the front head of the carrier. The diagnostic presently in operation consists in a viewing system offering accurate visual inspection of PFCs. Leak detection of first wall based on helium sniffing and laser compact system for carbon co-deposited layers characterizations or treatments are also considered for demonstration. In April 2008, the AIA robot equipped with its vision diagnostic has realized a complete deployment into Tore Supra and the first closed inspection of the vessel under UHV conditions. During the upcoming experimental campaign, the same operation will be performed under relevant conditions (10{sup -6} Pa and 120 deg. C) after a conditioning phase at 200 deg. C to avoid outgassing pollution of the chamber. This paper describes the different steps of the project development, robot capabilities with the present operations conducted on Tore Supra and future requirements for making the robot a tool for tokamak routine operation.

  4. Practical application with plc in manipulation of a robotic arm

    Directory of Open Access Journals (Sweden)

    Cristian Barz

    2014-12-01

    Full Text Available This paper presents the use of a robotic arm PLC Siemens in order not using CNC commands. This is done by programming the PLC ladder diagram language that makes movement on the three axes of the arm by means of stepper motors. Required command console PLC is built with the help of a touch screen HMI Weintek. In the user interface are introduced distances and displacement speeds on the three axes.

  5. Development and verification of ground-based tele-robotics operations concept for Dextre

    Science.gov (United States)

    Aziz, Sarmad

    2013-05-01

    The Special Purpose Dextreous Manipulator (Dextre) is the latest addition to the on-orbit segment of the Mobile Servicing System (MSS); Canada's contribution to the International Space Station (ISS). Launched in March 2008, the advanced two-armed robot is designed to perform various ISS maintenance tasks on robotically compatible elements and on-orbit replaceable units using a wide variety of tools and interfaces. The addition of Dextre has increased the capabilities of the MSS, and has introduced significant complexity to ISS robotics operations. While the initial operations concept for Dextre was based on human-in-the-loop control by the on-orbit astronauts, the complexities of robotic maintenance and the associated costs of training and maintaining the operator skills required for Dextre operations demanded a reexamination of the old concepts. A new approach to ISS robotic maintenance was developed in order to utilize the capabilities of Dextre safely and efficiently, while at the same time reducing the costs of on-orbit operations. This paper will describe the development, validation, and on-orbit demonstration of the operations concept for ground-based tele-robotics control of Dextre. It will describe the evolution of the new concepts from the experience gained from the development and implementation of the ground control capability for the Space Station Remote Manipulator System; Canadarm 2. It will discuss the various technical challenges faced during the development effort, such as requirements for high positioning accuracy, force/moment sensing and accommodation, failure tolerance, complex tool operations, and the novel operational tools and techniques developed to overcome them. The paper will also describe the work performed to validate the new concepts on orbit and will discuss the results and lessons learned from the on-orbit checkout and commissioning of Dextre using the newly developed tele-robotics techniques and capabilities.

  6. Three-dimensional neural net for learning visuomotor coordination of a robot arm.

    Science.gov (United States)

    Martinetz, T M; Ritter, H J; Schulten, K J

    1990-01-01

    An extension of T. Kohonen's (1982) self-organizing mapping algorithm together with an error-correction scheme based on the Widrow-Hoff learning rule is applied to develop a learning algorithm for the visuomotor coordination of a simulated robot arm. Learning occurs by a sequence of trial movements without the need for an external teacher. Using input signals from a pair of cameras, the closed robot arm system is able to reduce its positioning error to about 0.3% of the linear dimensions of its work space. This is achieved by choosing the connectivity of a three-dimensional lattice consisting of the units of the neural net.

  7. The evolution of the application of mobile robotics to nuclear facility operations and maintenance

    International Nuclear Information System (INIS)

    Carlton, R.E.; Bartholet, S.J.

    1987-01-01

    Application of the concept of mobile robotics to the operation and maintenance of nuclear facilities has evolved over the last four years due, in part, to the efforts of Odetics in the creation of the teleoperated legged transporter. The first step in this evolutionary process was the demonstration of the legged transporter technology, which was accomplished with the design, fabrication and testing of the Odex I functionoid. A second generation ODEX, delivered to the Robotics Technology Group at Savannah River Laboratories, represents the experimental phase of the process. This machine consists of a basic ODEX I transporter body with a unique manipulator arm mounted on a service turret. Currently, the prototype phase of the mobile robotic development effort is underway with the design of the ODEX III which includes enhanced mobility and dexterity, increased intelligence and greater strength in the manipulator arm and transporter

  8. Software Development for the Kinematic Analysis of a Lynx 6 Robot Arm

    OpenAIRE

    Baki Koyuncu; Mehmet Güzel

    2007-01-01

    The kinematics of manipulators is a central problem in the automatic control of robot manipulators. Theoretical background for the analysis of the 5 Dof Lynx-6 educational Robot Arm kinematics is presented in this paper. The kinematics problem is defined as the transformation from the Cartesian space to the joint space and vice versa. The Denavit-Harbenterg (D-H) model of representation is used to model robot links and joints in this study. Both forward and inverse kinematics solutions for th...

  9. Force-feedback tele operation of industrial robots a cost effective solution for decontamination of nuclear plants

    International Nuclear Information System (INIS)

    Desbats, P.; Andriot, C.; Gicquel, P.; Viallesoubranne, J.P.; Souche, C.

    1998-01-01

    Decontamination and maintenance in hot cells are some new emerging applications of industrial robots in the nuclear fuel cycle plants. Industrial robots are low cost, accurate and reliable manipulator arms which are used in manufacturing industries usually. Thanks to the recent evolution of robotics technologies, some industrial robots may be adapted to nuclear environment. These robots are transportable, sealed and can be decontaminated, and they may be 'hardened' up to a level of irradiation dose sufficient for operation in low and medium irradiating/contaminating environments. Although industrial robots are usually programmed to perform specific and repetitive tasks, they may be remotely tele-operated by human operators as well. This allows industrial robots to perform usual tele-manipulation tasks encountered in the nuclear plants and more. The paper presents the computer based tele-operation control system TAO2000 TM , developed by the Tele-operation and Robotics Service of CEA, which has been applied to the RX90 TM industrial robot from ST-UBLI company. This robot has been selected in order to perform various maintenance and decontamination tasks in COGEMA plants. TAO2000 provides the overall tele-robotic and robotic functions necessary to perform any remote tele-operation application in hostile environment: force-feedback master-slave control; computer- assisted tele-operation of mechanical processes; trajectory programming as well as various robotics functions; graphical modelling of working environment and simulation; automatic path planning with obstacle avoidance; man-machine interface for tasks programming and mission execution. Experimental results reported in the paper demonstrate the feasibility of force-feedback master-slave control of standard industrial robots. Finally, the design of new, cost effective. tele-operation systems based on industrial robots may be intended for nuclear plants maintenance. (author)

  10. Closed-Loop Hybrid Gaze Brain-Machine Interface Based Robotic Arm Control with Augmented Reality Feedback

    Directory of Open Access Journals (Sweden)

    Hong Zeng

    2017-10-01

    Full Text Available Brain-machine interface (BMI can be used to control the robotic arm to assist paralysis people for performing activities of daily living. However, it is still a complex task for the BMI users to control the process of objects grasping and lifting with the robotic arm. It is hard to achieve high efficiency and accuracy even after extensive trainings. One important reason is lacking of sufficient feedback information for the user to perform the closed-loop control. In this study, we proposed a method of augmented reality (AR guiding assistance to provide the enhanced visual feedback to the user for a closed-loop control with a hybrid Gaze-BMI, which combines the electroencephalography (EEG signals based BMI and the eye tracking for an intuitive and effective control of the robotic arm. Experiments for the objects manipulation tasks while avoiding the obstacle in the workspace are designed to evaluate the performance of our method for controlling the robotic arm. According to the experimental results obtained from eight subjects, the advantages of the proposed closed-loop system (with AR feedback over the open-loop system (with visual inspection only have been verified. The number of trigger commands used for controlling the robotic arm to grasp and lift the objects with AR feedback has reduced significantly and the height gaps of the gripper in the lifting process have decreased more than 50% compared to those trials with normal visual inspection only. The results reveal that the hybrid Gaze-BMI user can benefit from the information provided by the AR interface, improving the efficiency and reducing the cognitive load during the grasping and lifting processes.

  11. Closed-Loop Hybrid Gaze Brain-Machine Interface Based Robotic Arm Control with Augmented Reality Feedback

    Science.gov (United States)

    Zeng, Hong; Wang, Yanxin; Wu, Changcheng; Song, Aiguo; Liu, Jia; Ji, Peng; Xu, Baoguo; Zhu, Lifeng; Li, Huijun; Wen, Pengcheng

    2017-01-01

    Brain-machine interface (BMI) can be used to control the robotic arm to assist paralysis people for performing activities of daily living. However, it is still a complex task for the BMI users to control the process of objects grasping and lifting with the robotic arm. It is hard to achieve high efficiency and accuracy even after extensive trainings. One important reason is lacking of sufficient feedback information for the user to perform the closed-loop control. In this study, we proposed a method of augmented reality (AR) guiding assistance to provide the enhanced visual feedback to the user for a closed-loop control with a hybrid Gaze-BMI, which combines the electroencephalography (EEG) signals based BMI and the eye tracking for an intuitive and effective control of the robotic arm. Experiments for the objects manipulation tasks while avoiding the obstacle in the workspace are designed to evaluate the performance of our method for controlling the robotic arm. According to the experimental results obtained from eight subjects, the advantages of the proposed closed-loop system (with AR feedback) over the open-loop system (with visual inspection only) have been verified. The number of trigger commands used for controlling the robotic arm to grasp and lift the objects with AR feedback has reduced significantly and the height gaps of the gripper in the lifting process have decreased more than 50% compared to those trials with normal visual inspection only. The results reveal that the hybrid Gaze-BMI user can benefit from the information provided by the AR interface, improving the efficiency and reducing the cognitive load during the grasping and lifting processes. PMID:29163123

  12. Compliant behaviour of redundant robot arm - experiments with null-space

    Directory of Open Access Journals (Sweden)

    Petrović Petar B.

    2015-01-01

    Full Text Available This paper presents theoretical and experimental aspects of Jacobian nullspace use in kinematically redundant robots for achieving kinetostatically consistent control of their compliant behavior. When the stiffness of the robot endpoint is dominantly influenced by the compliance of the robot joints, generalized stiffness matrix can be mapped into joint space using appropriate congruent transformation. Actuation stiffness matrix achieved by this transformation is generally nondiagonal. Off-diagonal elements of the actuation matrix can be generated by redundant actuation only (polyarticular actuators, but such kind of actuation is very difficult to realize practically in technical systems. The approach of solving this problem which is proposed in this paper is based on the use of kinematic redundancy and nullspace of the Jacobian matrix. Evaluation of the developed analytical model was done numerically by a minimal redundant robot with one redundant d.o.f. and experimentally by a 7 d.o.f. Yaskawa SIA 10F robot arm. [Projekat Ministarstva nauke Republike Srbije, br. TR35007

  13. Dynamic parameter identification of robot arms with servo-controlled electrical motors

    Science.gov (United States)

    Jiang, Zhao-Hui; Senda, Hiroshi

    2005-12-01

    This paper addresses the issue of dynamic parameter identification of the robot manipulator with servo-controlled electrical motors. An assumption is made that all kinematical parameters, such as link lengths, are known, and only dynamic parameters containing mass, moment of inertia, and their functions need to be identified. First, we derive dynamics of the robot arm with a linear form of the unknown dynamic parameters by taking dynamic characteristics of the motor and servo unit into consideration. Then, we implement the parameter identification approach to identify the unknown parameters with respect to individual link separately. A pseudo-inverse matrix is used for formulation of the parameter identification. The optimal solution is guaranteed in a sense of least-squares of the mean errors. A Direct Drive (DD) SCARA type industrial robot arm AdeptOne is used as an application example of the parameter identification. Simulations and experiments for both open loop and close loop controls are carried out. Comparison of the results confirms the correctness and usefulness of the parameter identification and the derived dynamic model.

  14. Whole-arm tactile sensing for beneficial and acceptable contact during robotic assistance.

    Science.gov (United States)

    Grice, Phillip M; Killpack, Marc D; Jain, Advait; Vaish, Sarvagya; Hawke, Jeffrey; Kemp, Charles C

    2013-06-01

    Many assistive tasks involve manipulation near the care-receiver's body, including self-care tasks such as dressing, feeding, and personal hygiene. A robot can provide assistance with these tasks by moving its end effector to poses near the care-receiver's body. However, perceiving and maneuvering around the care-receiver's body can be challenging due to a variety of issues, including convoluted geometry, compliant materials, body motion, hidden surfaces, and the object upon which the body is resting (e.g., a wheelchair or bed). Using geometric simulations, we first show that an assistive robot can achieve a much larger percentage of end-effector poses near the care-receiver's body if its arm is allowed to make contact. Second, we present a novel system with a custom controller and whole-arm tactile sensor array that enables a Willow Garage PR2 to regulate contact forces across its entire arm while moving its end effector to a commanded pose. We then describe tests with two people with motor impairments, one of whom used the system to grasp and pull a blanket over himself and to grab a cloth and wipe his face, all while in bed at his home. Finally, we describe a study with eight able-bodied users in which they used the system to place objects near their bodies. On average, users perceived the system to be safe and comfortable, even though substantial contact occurred between the robot's arm and the user's body.

  15. Kinect-Based Sliding Mode Control for Lynxmotion Robotic Arm

    Directory of Open Access Journals (Sweden)

    Ismail Ben Abdallah

    2016-01-01

    Full Text Available Recently, the technological development of manipulator robot increases very quickly and provides a positive impact to human life. The implementation of the manipulator robot technology offers more efficiency and high performance for several human’s tasks. In reality, efforts published in this context are focused on implementing control algorithms with already preprogrammed desired trajectories (passive robots case or trajectory generation based on feedback sensors (active robots case. However, gesture based control robot can be considered as another channel of system control which is not widely discussed. This paper focuses on a Kinect-based real-time interactive control system implementation. Based on LabVIEW integrated development environment (IDE, a developed human-machine-interface (HMI allows user to control in real time a Lynxmotion robotic arm. The Kinect software development kit (SDK provides a tool to keep track of human body skeleton and abstract it into 3-dimensional coordinates. Therefore, the Kinect sensor is integrated into our control system to detect the different user joints coordinates. The Lynxmotion dynamic has been implemented in a real-time sliding mode control algorithm. The experimental results are carried out to test the effectiveness of the system, and the results verify the tracking ability, stability, and robustness.

  16. Development of a 3D-Printed Robotic Prosthetic Arm

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Martinez, M.; Garcia-Miquel, A.; Vidal Martinez, N.

    2016-07-01

    Current prostheses are not affordable to the general public. 3D printing technology may allow low-cost production of such devices, making them more readily accessible to people in need. This contribution presents the set-up and the considerations that have to be taken into account to develop a functional artificial upper limb prototype. The robotic prosthetic arm reported herein was produced entirely using 3D printing technology to demonstrate its feasibility on a limited budget. The project was developed to integrate two different functional modes: a prosthetic application and a remote application. The prosthetic application is intended to emulate existing prosthetic devices using myoelectric sensors. The remote application is conceived as a tool for prevention, by providing the general public with a device that could carry out activities that entail a risk of severe physical injury. This is achieved using a hand-tracking system that allows the robotic arm to copy the user’s movements remotely and in real time. The outcome of the validation tests has been considerably successful for both applications and the total costs are on target. (Author)

  17. Novel Adaptive Forward Neural MIMO NARX Model for the Identification of Industrial 3-DOF Robot Arm Kinematics

    Directory of Open Access Journals (Sweden)

    Ho Pham Huy Anh

    2012-10-01

    Full Text Available In this paper, a novel forward adaptive neural MIMO NARX model is used for modelling and identifying the forward kinematics of an industrial 3-DOF robot arm system. The nonlinear features of the forward kinematics of the industrial robot arm drive are thoroughly modelled based on the forward adaptive neural NARX model-based identification process using experimental input-output training data. This paper proposes a novel use of a back propagation (BP algorithm to generate the forward neural MIMO NARX (FNMN model for the forward kinematics of the industrial 3-DOF robot arm. The results show that the proposed adaptive neural NARX model trained by a Back Propagation learning algorithm yields outstanding performance and perfect accuracy.

  18. Crimped braided sleeves for soft, actuating arm in robotic abdominal surgery.

    Science.gov (United States)

    Elsayed, Yahya; Lekakou, Constantina; Ranzani, Tommaso; Cianchetti, Matteo; Morino, Mario; Arezzo, Alberto; Menciassi, Arianna; Geng, Tao; Saaj, Chakravarthini M

    2015-01-01

    This paper investigates different types of crimped, braided sleeve used for a soft arm for robotic abdominal surgery, with the sleeve required to contain balloon expansion in the pneumatically actuating arm while it follows the required bending, elongation and diameter reduction of the arm. Three types of crimped, braided sleeves from PET (BraidPET) or nylon (BraidGreyNylon and BraidNylon, with different monofilament diameters) were fabricated and tested including geometrical and microstructural characterisation of the crimp and braid, mechanical tests and medical scratching tests for organ damage of domestic pigs. BraidPET caused some organ damage, sliding under normal force of 2-5 N; this was attributed to the high roughness of the braid pattern, the higher friction coefficient of polyethylene terephthalate (PET) compared to nylon, and the high frequency of the crimp peaks for this sleeve. No organ damage was observed for the BraidNylon, attributed to both the lower roughness of the braid pattern and the low friction coefficient of nylon. BraidNylon also required the lowest tensile force during its elongation to similar maximum strain as that of BraidPET, translating to low power requirements. BraidNylon is recommended for the crimped sleeve of the arm designed for robotic abdominal surgery.

  19. Grasp planning for a reconfigurable parallel robot with an underactuated arm structure

    Directory of Open Access Journals (Sweden)

    M. Riedel

    2010-12-01

    Full Text Available In this paper, a novel approach of grasp planning is applied to find out the appropriate grasp points for a reconfigurable parallel robot called PARAGRIP (Parallel Gripping. This new handling system is able to manipulate objects in the six-dimensional Cartesian space by several robotic arms using only six actuated joints. After grasping, the contact elements at the end of the underactuated arm mechanisms are connected to the object which forms a closed loop mechanism similar to the architecture of parallel manipulators. As the mounting and grasp points of the arms can easily be changed, the manipulator can be reconfigured to match the user's preferences and needs. This paper raises the question, how and where these grasp points are to be placed on the object to perform well for a certain manipulation task.

    This paper was presented at the IFToMM/ASME International Workshop on Underactuated Grasping (UG2010, 19 August 2010, Montréal, Canada.

  20. Four-arm single docking full robotic surgery for low rectal cancer: technique standardization

    Directory of Open Access Journals (Sweden)

    José Reinan Ramos

    Full Text Available The authors present the four-arm single docking full robotic surgery to treat low rectal cancer. The eight main operative steps are: 1- patient positioning; 2- trocars set-up and robot docking; 3- sigmoid colon, left colon and splenic flexure mobilization (lateral-to-medial approach; 4-Inferior mesenteric artery and vein ligation (medial-to-lateral approach; 5- total mesorectum excision and preservation of hypogastric and pelvic autonomic nerves (sacral dissection, lateral dissection, pelvic dissection; 6- division of the rectum using an endo roticulator stapler for the laparoscopic performance of a double-stapled coloanal anastomosis (type I tumor; 7- intersphincteric resection, extraction of the specimen through the anus and lateral-to-end hand sewn coloanal anastomosis (type II tumor; 8- cylindric abdominoperineal resection, with transabdominal section of the levator muscles (type IV tumor. The techniques employed were safe and have presented low rates of complication and no mortality.

  1. An Electromechanical Pendulum Robot Arm in Action: Dynamics and Control

    Directory of Open Access Journals (Sweden)

    A. Notué Kadjie

    2017-01-01

    Full Text Available The authors numerically investigate the dynamics and control of an electromechanical robot arm consisting of a pendulum coupled to an electrical circuit via an electromagnetic mechanism. The analysis of the dynamical behavior of the electromechanical device powered by a sinusoidal power source is carried out when the effects of the loads on the arm are neglected. It is found that the device exhibits period-n T oscillations and high amplitude oscillations when the electric current is at its smallest value. The specific case which considers the effects of the impulsive contact force caused by an external load mass pushed by the arm is also studied. It is found that the amplitude of the impulse force generates several behaviors such as jump of amplitude and distortions of the mechanical vibration and electrical signal. For more efficient functioning of the device, both piezoelectric and adaptive backstepping controls are applied on the system. It is found that the control strategies are able to mitigate the signal distortion and restore the dynamical behavior to its normal state or reduce the effects of perturbations such as a short time variation of one component or when the robot system is subject to noises.

  2. Automation and use of robotic arm for development and routine production of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Salvadori, P.A.; Di Sacco, S.; Riva, A.; Fusani, L.

    1993-01-01

    The target of a radiopharmaceutical group is twofold: production of radiotracers for clinical use (routine) and development of new compounds. The level of activity to be handled selects the strategy to be used for radiocompounds handling, ranging from direct manipulation during basic development at microcurie level to sophisticated equipments such as automated black-boxes and robotic arms at curie level. The authors looked for a common solution, to both the management of routine productions and the problems arising during activity scaling up in new tracer development, by choosing a robotic arm integrated by a variety of specialized automatic devices able to perform actions which are difficult (too slow, too precise, too complicated, etc.,) to be made by the robot. The final solution from this approach is a open-quotes synthetic stationclose quotes with flexible architecture which can be used for different applications without harware modification/adaptation

  3. Hybrid Taguchi DNA Swarm Intelligence for Optimal Inverse Kinematics Redundancy Resolution of Six-DOF Humanoid Robot Arms

    Directory of Open Access Journals (Sweden)

    Hsu-Chih Huang

    2014-01-01

    Full Text Available This paper presents a hybrid Taguchi deoxyribonucleic acid (DNA swarm intelligence for solving the inverse kinematics redundancy problem of six degree-of-freedom (DOF humanoid robot arms. The inverse kinematics problem of the multi-DOF humanoid robot arm is redundant and has no general closed-form solutions or analytical solutions. The optimal joint configurations are obtained by minimizing the predefined performance index in DNA algorithm for real-world humanoid robotics application. The Taguchi method is employed to determine the DNA parameters to search for the joint solutions of the six-DOF robot arms more efficiently. This approach circumvents the disadvantage of time-consuming tuning procedure in conventional DNA computing. Simulation results are conducted to illustrate the effectiveness and merit of the proposed methods. This Taguchi-based DNA (TDNA solver outperforms the conventional solvers, such as geometric solver, Jacobian-based solver, genetic algorithm (GA solver and ant, colony optimization (ACO solver.

  4. [Digital imaging and robotics in endoscopic surgery].

    Science.gov (United States)

    Go, P M

    1998-05-23

    The introduction of endoscopical surgery has among other things influenced technical developments in surgery. Owing to digitalisation, major progress will be made in imaging and in the sophisticated technology sometimes called robotics. Digital storage makes the results of imaging diagnostics (e.g. the results of radiological examination) suitable for transmission via video conference systems for telediagnostic purposes. The availability of digital video technique renders possible the processing, storage and retrieval of moving images as well. During endoscopical operations use may be made of a robot arm which replaces the camera man. The arm does not grow tired and provides a stable image. The surgeon himself can operate or address the arm and it can remember fixed image positions to which it can return if ordered to do so. The next step is to carry out surgical manipulations via a robot arm. This may make operations more patient-friendly. A robot arm can also have remote control: telerobotics. At the Internet site of this journal a number of supplements to this article can be found, for instance three-dimensional (3D) illustrations (which is the purpose of the 3D spectacles enclosed with this issue) and a quiz (http:@appendix.niwi. knaw.nl).

  5. On the Value of Estimating Human Arm Stiffness during Virtual Teleoperation with Robotic Manipulators.

    Science.gov (United States)

    Buzzi, Jacopo; Ferrigno, Giancarlo; Jansma, Joost M; De Momi, Elena

    2017-01-01

    Teleoperated robotic systems are widely spreading in multiple different fields, from hazardous environments exploration to surgery. In teleoperation, users directly manipulate a master device to achieve task execution at the slave robot side; this interaction is fundamental to guarantee both system stability and task execution performance. In this work, we propose a non-disruptive method to study the arm endpoint stiffness. We evaluate how users exploit the kinetic redundancy of the arm to achieve stability and precision during the execution of different tasks with different master devices. Four users were asked to perform two planar trajectories following virtual tasks using both a serial and a parallel link master device. Users' arm kinematics and muscular activation were acquired and combined with a user-specific musculoskeletal model to estimate the joint stiffness. Using the arm kinematic Jacobian, the arm end-point stiffness was derived. The proposed non-disruptive method is capable of estimating the arm endpoint stiffness during the execution of virtual teleoperated tasks. The obtained results are in accordance with the existing literature in human motor control and show, throughout the tested trajectory, a modulation of the arm endpoint stiffness that is affected by task characteristics and hand speed and acceleration.

  6. On the Value of Estimating Human Arm Stiffness during Virtual Teleoperation with Robotic Manipulators

    Directory of Open Access Journals (Sweden)

    Jacopo Buzzi

    2017-09-01

    Full Text Available Teleoperated robotic systems are widely spreading in multiple different fields, from hazardous environments exploration to surgery. In teleoperation, users directly manipulate a master device to achieve task execution at the slave robot side; this interaction is fundamental to guarantee both system stability and task execution performance. In this work, we propose a non-disruptive method to study the arm endpoint stiffness. We evaluate how users exploit the kinetic redundancy of the arm to achieve stability and precision during the execution of different tasks with different master devices. Four users were asked to perform two planar trajectories following virtual tasks using both a serial and a parallel link master device. Users' arm kinematics and muscular activation were acquired and combined with a user-specific musculoskeletal model to estimate the joint stiffness. Using the arm kinematic Jacobian, the arm end-point stiffness was derived. The proposed non-disruptive method is capable of estimating the arm endpoint stiffness during the execution of virtual teleoperated tasks. The obtained results are in accordance with the existing literature in human motor control and show, throughout the tested trajectory, a modulation of the arm endpoint stiffness that is affected by task characteristics and hand speed and acceleration.

  7. Application of a Dual-Arm Robot in Complex Sample Preparation and Measurement Processes.

    Science.gov (United States)

    Fleischer, Heidi; Drews, Robert Ralf; Janson, Jessica; Chinna Patlolla, Bharath Reddy; Chu, Xianghua; Klos, Michael; Thurow, Kerstin

    2016-10-01

    Automation systems with applied robotics have already been established in industrial applications for many years. In the field of life sciences, a comparable high level of automation can be found in the areas of bioscreening and high-throughput screening. Strong deficits still exist in the development of flexible and universal fully automated systems in the field of analytical measurement. Reasons are the heterogeneous processes with complex structures, which include sample preparation and transport, analytical measurements using complex sensor systems, and suitable data analysis and evaluation. Furthermore, the use of nonstandard sample vessels with various shapes and volumes results in an increased complexity. The direct use of existing automation solutions from bioscreening applications is not possible. A flexible automation system for sample preparation, analysis, and data evaluation is presented in this article. It is applied for the determination of cholesterol in biliary endoprosthesis using gas chromatography-mass spectrometry (GC-MS). A dual-arm robot performs both transport and active manipulation tasks to ensure human-like operation. This general robotic concept also enables the use of manual laboratory devices and equipment and is thus suitable in areas with a high standardization grade. © 2016 Society for Laboratory Automation and Screening.

  8. Integration of a Robotic Arm with the Surgical Assistant Workstation Software Framework

    OpenAIRE

    Young, J.; Elhawary, H.; Popovic, A.

    2012-01-01

    We have integrated the Philips Research robot arm with the Johns Hopkins University cisst library, an open-source platform for computerassisted surgical intervention. The development of a Matlab to C++ wrapper to abstract away servo-level details facilitates the rapid development of a component-based framework with “plug and play” features. This allows the user to easily exchange the robot with an alternative manipulator while maintaining the same overall functionality.

  9. Goal driven kinematic simulation of flexible arm robot for space station missions

    Science.gov (United States)

    Janssen, P.; Choudry, A.

    1987-01-01

    Flexible arms offer a great degree of flexibility in maneuvering in the space environment. The problem of transporting an astronaut for extra-vehicular activity using a space station based flexible arm robot was studied. Inverse kinematic solutions of the multilink structure were developed. The technique is goal driven and can support decision making for configuration selection as required for stability and obstacle avoidance. Details of this technique and results are given.

  10. Soft-robotic arm inspired by the octopus: II. From artificial requirements to innovative technological solutions

    International Nuclear Information System (INIS)

    Mazzolai, B; Margheri, L; Cianchetti, M; Dario, P; Laschi, C

    2012-01-01

    Soft robotics is a current focus in robotics research because of the expected capability of soft robots to better interact with real-world environments. As a point of inspiration in the development of innovative technologies in soft robotics, octopuses are particularly interesting ‘animal models’. Octopus arms have unique biomechanical capabilities that combine significant pliability with the ability to exert a great deal of force, because they lack rigid structures but can change and control their degree of stiffness. The octopus arm motor capability is a result of the peculiar arrangement of its muscles and the properties of its tissues. These special abilities have been investigated by the authors in a specific study dedicated to identifying the key principles underlying these biological functions and deriving engineering requirements for robotics solutions. This paper, which is the second in a two-part series, presents how the identified requirements can be used to create innovative technological solutions, such as soft materials, mechanisms and actuators. Experiments indicate the ability of these proposed solutions to ensure the same performance as in the biological model in terms of compliance, elongation and force. These results represent useful and relevant components of innovative soft-robotic systems and suggest their potential use to create a new generation of highly dexterous, soft-bodied robots. (paper)

  11. Brain-Machine Interface control of a robot arm using actor-critic rainforcement learning.

    Science.gov (United States)

    Pohlmeyer, Eric A; Mahmoudi, Babak; Geng, Shijia; Prins, Noeline; Sanchez, Justin C

    2012-01-01

    Here we demonstrate how a marmoset monkey can use a reinforcement learning (RL) Brain-Machine Interface (BMI) to effectively control the movements of a robot arm for a reaching task. In this work, an actor-critic RL algorithm used neural ensemble activity in the monkey's motor cortext to control the robot movements during a two-target decision task. This novel approach to decoding offers unique advantages for BMI control applications. Compared to supervised learning decoding methods, the actor-critic RL algorithm does not require an explicit set of training data to create a static control model, but rather it incrementally adapts the model parameters according to its current performance, in this case requiring only a very basic feedback signal. We show how this algorithm achieved high performance when mapping the monkey's neural states (94%) to robot actions, and only needed to experience a few trials before obtaining accurate real-time control of the robot arm. Since RL methods responsively adapt and adjust their parameters, they can provide a method to create BMIs that are robust against perturbations caused by changes in either the neural input space or the output actions they generate under different task requirements or goals.

  12. On-line trajectory planning of time-jerk optimal for robotic arms

    Directory of Open Access Journals (Sweden)

    Nadir Bendali

    2016-09-01

    Full Text Available A method based on the computation of the time intervals of the knots for time-jerk optimal planning under kinematic constraints of robot manipulators in predefined operations is described in this paper. In order to ensure that the resulting trajectory is smooth enough, a cost function containing a term proportional to the integral of the squared jerk (defined as the derivative of the acceleration along the trajectory is considered. Moreover, a second term, proportional to the total execution time, is added to the expression of the cost function. A Cubic Spline functions are then used to compose overall trajectory. This method can meet the requirements of a short execution time and low arm vibration of the manipulator and the simulation provides good results.

  13. Patient-specific surgical simulator for the pre-operative planning of single-incision laparoscopic surgery with bimanual robots.

    Science.gov (United States)

    Turini, Giuseppe; Moglia, Andrea; Ferrari, Vincenzo; Ferrari, Mauro; Mosca, Franco

    2012-01-01

    The trend of surgical robotics is to follow the evolution of laparoscopy, which is now moving towards single-incision laparoscopic surgery. The main drawback of this approach is the limited maneuverability of the surgical tools. Promising solutions to improve the surgeon's dexterity are based on bimanual robots. However, since both robot arms are completely inserted into the patient's body, issues related to possible unwanted collisions with structures adjacent to the target organ may arise. This paper presents a simulator based on patient-specific data for the positioning and workspace evaluation of bimanual surgical robots in the pre-operative planning of single-incision laparoscopic surgery. The simulator, designed for the pre-operative planning of robotic laparoscopic interventions, was tested by five expert surgeons who evaluated its main functionalities and provided an overall rating for the system. The proposed system demonstrated good performance and usability, and was designed to integrate both present and future bimanual surgical robots.

  14. Pedicle Screw Insertion Accuracy Using O-Arm, Robotic Guidance, or Freehand Technique: A Comparative Study.

    Science.gov (United States)

    Laudato, Pietro Aniello; Pierzchala, Katarzyna; Schizas, Constantin

    2018-03-15

    A retrospective radiological study. The aim of this study was to evaluate the accuracy of pedicle screw insertion using O-Arm navigation, robotic assistance, or a freehand fluoroscopic technique. Pedicle screw insertion using either "O-Arm" navigation or robotic devices is gaining popularity. Although several studies are available evaluating each of those techniques separately, no direct comparison has been attempted. Eighty-four patients undergoing implantation of 569 lumbar and thoracic screws were divided into three groups. Eleven patients (64 screws) had screws inserted using robotic assistance, 25 patients (191 screws) using the O-arm, while 48 patients (314 screws) had screws inserted using lateral fluoroscopy in a freehand technique. A single experienced spine surgeon assisted by a spinal fellow performed all procedures. Screw placement accuracy was assessed by two independent observers on postoperative computed tomography (CTs) according to the A to D Rampersaud criteria. No statistically significant difference was noted between the three groups. About 70.4% of screws in the freehand group, 69.6% in the O arm group, and 78.8% in the robotic group were placed completely within the pedicle margins (grade A) (P > 0.05). About 6.4% of screws were considered misplaced (grades C&D) in the freehand group, 4.2% in the O-arm group, and 4.7% in the robotic group (P > 0.05). The spinal fellow inserted screws with the same accuracy as the senior surgeon (P > 0.05). The advent of new technologies does not appear to alter accuracy of screw placement in our setting. Under supervision, spinal fellows might perform equally well to experienced surgeons using new tools. The lack of difference in accuracy does not imply that the above-mentioned techniques have no added advantages. Other issues, such as surgeon/patient radiation, fiddle factor, teaching suitability, etc., outside the scope of our present study, need further assessment. 3.

  15. The implementation of common object request broker architecture (CORBA) for controlling robot arm via web

    International Nuclear Information System (INIS)

    Syed Mahamad Zuhdi Amin; Mohd Yazid Idris; Wan Mohd Nasir Wan Kadir

    2001-01-01

    This paper presents the employment of the Common Object Request Broker Architecture (CORBA) technology in the implementation of our distributed Arm Robot Controller (ARC). CORBA is an industrial standard architecture based on distributed abstract object model, which is developed by Object Management Group (OMG). The architecture consists of five components i.e. Object Request Broker (ORB), Interface Definition Language (IDL), Dynamic Invocation Interface (DII), Interface Repositories (IR) and Object adapter (OA). CORBA objects are different from typical programming objects in three ways i.e. they can be executed on any platform, located anywhere on the network and written in any language that supports IDL mapping. In the implementation of the system, 5 degree of freedom (DOF) arm robot RCS 6.0 and Java as a programming mapping to the CORBA IDL. By implementing this architecture, the objects in the server machine can be distributed over the network in order to run the controller. the ultimate goal for our ARC system is to demonstrate concurrent execution of multiple arm robots through multiple instantiations of distributed object components. (Author)

  16. Visual-perceptual mismatch in robotic surgery.

    Science.gov (United States)

    Abiri, Ahmad; Tao, Anna; LaRocca, Meg; Guan, Xingmin; Askari, Syed J; Bisley, James W; Dutson, Erik P; Grundfest, Warren S

    2017-08-01

    The principal objective of the experiment was to analyze the effects of the clutch operation of robotic surgical systems on the performance of the operator. The relative coordinate system introduced by the clutch operation can introduce a visual-perceptual mismatch which can potentially have negative impact on a surgeon's performance. We also assess the impact of the introduction of additional tactile sensory information on reducing the impact of visual-perceptual mismatch on the performance of the operator. We asked 45 novice subjects to complete peg transfers using the da Vinci IS 1200 system with grasper-mounted, normal force sensors. The task involves picking up a peg with one of the robotic arms, passing it to the other arm, and then placing it on the opposite side of the view. Subjects were divided into three groups: aligned group (no mismatch), the misaligned group (10 cm z axis mismatch), and the haptics-misaligned group (haptic feedback and z axis mismatch). Each subject performed the task five times, during which the grip force, time of completion, and number of faults were recorded. Compared to the subjects that performed the tasks using a properly aligned controller/arm configuration, subjects with a single-axis misalignment showed significantly more peg drops (p = 0.011) and longer time to completion (p sensors showed no difference between the different groups. The visual-perceptual mismatch created by the misalignment of the robotic controls relative to the robotic arms has a negative impact on the operator of a robotic surgical system. Introduction of other sensory information and haptic feedback systems can help in potentially reducing this effect.

  17. Brain-state dependent robotic reaching movement with a multi-joint arm exoskeleton: combining brain-machine interfacing and robotic rehabilitation

    Directory of Open Access Journals (Sweden)

    Daniel eBrauchle

    2015-10-01

    Full Text Available While robot-assisted arm and hand training after stroke allows for intensive task-oriented practice, it has provided only limited additional benefit over dose-matched physiotherapy up to now. These rehabilitation devices are possibly too supportive during the exercises. Neurophysiological signals might be one way of avoiding slacking and providing robotic support only when the brain is particularly responsive to peripheral input.We tested the feasibility of three-dimensional robotic assistance for reach-to-grasp movements with a multi-joint exoskeleton during motor imagery-related desynchronization of sensorimotor oscillations in the β-band only. We also registered task-related network changes of cortical functional connectivity by electroencephalography via the imaginary part of the coherence function.Healthy subjects and stroke survivors showed similar patterns – but different aptitudes – of controlling the robotic movement. All participants in this pilot study with nine healthy subjects and two stroke patients achieved their maximum performance during the early stages of the task. Robotic control was significantly higher and less variable when proprioceptive feedback was provided in addition to visual feedback, i.e. when the orthosis was actually attached to the subject’s arm during the task. A distributed cortical network of task-related coherent activity in the θ-band showed significant differences between healthy subjects and stroke patients as well as between early and late periods of the task.Brain-robot interfaces may successfully link three-dimensional robotic training to the participants’ efforts and allow for task-oriented practice of activities of daily living with a physiologically controlled multi-joint exoskeleton. Changes of cortical physiology during the task might also help to make subject-specific adjustments of task difficulty and guide adjunct interventions to facilitate motor learning for functional restoration.

  18. Development of a Stereo Vision Measurement System for a 3D Three-Axial Pneumatic Parallel Mechanism Robot Arm

    Directory of Open Access Journals (Sweden)

    Chien-Lun Hou

    2011-02-01

    Full Text Available In this paper, a stereo vision 3D position measurement system for a three-axial pneumatic parallel mechanism robot arm is presented. The stereo vision 3D position measurement system aims to measure the 3D trajectories of the end-effector of the robot arm. To track the end-effector of the robot arm, the circle detection algorithm is used to detect the desired target and the SAD algorithm is used to track the moving target and to search the corresponding target location along the conjugate epipolar line in the stereo pair. After camera calibration, both intrinsic and extrinsic parameters of the stereo rig can be obtained, so images can be rectified according to the camera parameters. Thus, through the epipolar rectification, the stereo matching process is reduced to a horizontal search along the conjugate epipolar line. Finally, 3D trajectories of the end-effector are computed by stereo triangulation. The experimental results show that the stereo vision 3D position measurement system proposed in this paper can successfully track and measure the fifth-order polynomial trajectory and sinusoidal trajectory of the end-effector of the three- axial pneumatic parallel mechanism robot arm.

  19. Robotics Offer Newfound Surgical Capabilities

    Science.gov (United States)

    2008-01-01

    Barrett Technology Inc., of Cambridge, Massachusetts, completed three Phase II Small Business Innovation Research (SBIR) contracts with Johnson Space Center, during which the company developed and commercialized three core technologies: a robotic arm, a hand that functions atop the arm, and a motor driver to operate the robotics. Among many industry uses, recently, an adaptation of the arm has been cleared by the U.S. Food and Drug Administration (FDA) for use in a minimally invasive knee surgery procedure, where its precision control makes it ideal for inserting a very small implant.

  20. A novel teaching system for industrial robots.

    Science.gov (United States)

    Lin, Hsien-I; Lin, Yu-Hsiang

    2014-03-27

    The most important tool for controlling an industrial robotic arm is a teach pendant, which controls the robotic arm movement in work spaces and accomplishes teaching tasks. A good teaching tool should be easy to operate and can complete teaching tasks rapidly and effortlessly. In this study, a new teaching system is proposed for enabling users to operate robotic arms and accomplish teaching tasks easily. The proposed teaching system consists of the teach pen, optical markers on the pen, a motion capture system, and the pen tip estimation algorithm. With the marker positions captured by the motion capture system, the pose of the teach pen is accurately calculated by the pen tip algorithm and used to control the robot tool frame. In addition, Fitts' Law is adopted to verify the usefulness of this new system, and the results show that the system provides high accuracy, excellent operation performance, and a stable error rate. In addition, the system maintains superior performance, even when users work on platforms with different inclination angles.

  1. Pyrotechnic robot - constructive design and command

    Directory of Open Access Journals (Sweden)

    Ionel A. Staretu

    2013-10-01

    Full Text Available Pyrotechnic robots are service robots used to reduce the time for intervention of pyrotechnic troops and to diminish the danger for the operators. Pyrotechnic robots are used to inspect dangerous areas or/and to remove and to distroy explosive or suspicious devices/objects. These robots can be used to make corridors through mined battle fields, for manipulation and neutralization of unexploded ammunition, for inspection of vehicles, trains, airplanes and buildings. For these robots, a good functional activity is determined with regard to work space dimensions,, robotic arm kinematics and gripper characteristics. The paper shows the structural, kinematic, static synthesis and analysis as well as the design and functional simulation of the robotic arm and the grippers attached on the pyrotechnic robot designed by the authors.

  2. Task oriented evaluation system for maintenance robots

    International Nuclear Information System (INIS)

    Asame, Hajime; Endo, Isao; Kotosaka, Shin-ya; Takata, Shozo; Hiraoka, Hiroyuki; Kohda, Takehisa; Matsumoto, Akihiro; Yamagishi, Kiichiro.

    1994-01-01

    The adaptability evaluation of maintenance robots to autonomous plants has been discussed. In this paper, a new concept of autonomous plant with maintenance robots are introduced, and a framework of autonomous maintenance system is proposed. Then, task-oriented evaluation of robot arms is discussed for evaluating their adaptability to maintenance tasks, and a new criterion called operability is proposed for adaptability evaluation. The task-oriented evaluation system is implemented and applied to structural design of robot arms. Using genetic algorithm, an optimal structure adaptable to a pump disassembly task is obtained. (author)

  3. Mentoring console improves collaboration and teaching in surgical robotics.

    Science.gov (United States)

    Hanly, Eric J; Miller, Brian E; Kumar, Rajesh; Hasser, Christopher J; Coste-Maniere, Eve; Talamini, Mark A; Aurora, Alexander A; Schenkman, Noah S; Marohn, Michael R

    2006-10-01

    One of the most significant limitations of surgical robots has been their inability to allow multiple surgeons and surgeons-in-training to engage in collaborative control of robotic surgical instruments. We report the initial experience with a novel two-headed da Vinci surgical robot that has two collaborative modes: the "swap" mode allows two surgeons to simultaneously operate and actively swap control of the robot's four arms, and the "nudge" mode allows them to share control of two of the robot's arms. The utility of the mentoring console operating in its two collaborative modes was evaluated through a combination of dry laboratory exercises and animal laboratory surgery. The results from surgeon-resident collaborative performance of complex three-handed surgical tasks were compared to results from single-surgeon and single-resident performance. Statistical significance was determined using Student's t-test. Collaborative surgeon-resident swap control reduced the time to completion of complex three-handed surgical tasks by 25% compared to single-surgeon operation of a four-armed da Vinci (P nudge mode was particularly useful for guiding a resident's hands during crucially precise steps of an operation (such as proper placement of stitches). The da Vinci mentoring console greatly facilitates surgeon collaboration during robotic surgery and improves the performance of complex surgical tasks. The mentoring console has the potential to improve resident participation in surgical robotics cases, enhance resident education in surgical training programs engaged in surgical robotics, and improve patient safety during robotic surgery.

  4. Passive reach and grasp with functional electrical stimulation and robotic arm support

    NARCIS (Netherlands)

    Westerveld, Ard J.; Schouten, Alfred C.; Veltink, Peter H.; van der Kooij, Herman

    2014-01-01

    Rehabilitation of arm and hand function is crucial to increase functional independence of stroke subjects. Here, we investigate the technical feasibility of an integrated training system combining robotics and functional electrical stimulation (FES) to support reach and grasp during functional

  5. Filtering sensory information with XCSF: improving learning robustness and robot arm control performance.

    Science.gov (United States)

    Kneissler, Jan; Stalph, Patrick O; Drugowitsch, Jan; Butz, Martin V

    2014-01-01

    It has been shown previously that the control of a robot arm can be efficiently learned using the XCSF learning classifier system, which is a nonlinear regression system based on evolutionary computation. So far, however, the predictive knowledge about how actual motor activity changes the state of the arm system has not been exploited. In this paper, we utilize the forward velocity kinematics knowledge of XCSF to alleviate the negative effect of noisy sensors for successful learning and control. We incorporate Kalman filtering for estimating successive arm positions, iteratively combining sensory readings with XCSF-based predictions of hand position changes over time. The filtered arm position is used to improve both trajectory planning and further learning of the forward velocity kinematics. We test the approach on a simulated kinematic robot arm model. The results show that the combination can improve learning and control performance significantly. However, it also shows that variance estimates of XCSF prediction may be underestimated, in which case self-delusional spiraling effects can hinder effective learning. Thus, we introduce a heuristic parameter, which can be motivated by theory, and which limits the influence of XCSF's predictions on its own further learning input. As a result, we obtain drastic improvements in noise tolerance, allowing the system to cope with more than 10 times higher noise levels.

  6. Kinematics and control of redundant robotic arm based on dielectric elastomer actuators

    Science.gov (United States)

    Branz, Francesco; Antonello, Andrea; Carron, Andrea; Carli, Ruggero; Francesconi, Alessandro

    2015-04-01

    Soft robotics is a promising field and its application to space mechanisms could represent a breakthrough in space technologies by enabling new operative scenarios (e.g. soft manipulators, capture systems). Dielectric Elastomers Actuators have been under deep study for a number of years and have shown several advantages that could be of key importance for space applications. Among such advantages the most notable are high conversion efficiency, distributed actuation, self-sensing capability, multi-degree-of-freedom design, light weight and low cost. The big potentialities of double cone actuators have been proven in terms of good performances (i.e. stroke and force/torque), ease of manufacturing and durability. In this work the kinematic, dynamic and control design of a two-joint redundant robotic arm is presented. Two double cone actuators are assembled in series to form a two-link design. Each joint has two degrees of freedom (one rotational and one translational) for a total of four. The arm is designed to move in a 2-D environment (i.e. the horizontal plane) with 4 DoF, consequently having two degrees of redundancy. The redundancy is exploited in order to minimize the joint loads. The kinematic design with redundant Jacobian inversion is presented. The selected control algorithm is described along with the results of a number of dynamic simulations that have been executed for performance verification. Finally, an experimental setup is presented based on a flexible structure that counteracts gravity during testing in order to better emulate future zero-gravity applications.

  7. Integration of a Robotic Arm with the Surgical Assistant Workstation Software Framework

    NARCIS (Netherlands)

    Young, J.; Elhawary, H.; Popovic, A.

    2012-01-01

    We have integrated the Philips Research robot arm with the Johns Hopkins University cisst library, an open-source platform for computerassisted surgical intervention. The development of a Matlab to C++ wrapper to abstract away servo-level details facilitates the rapid development of a

  8. Soft robotic arm inspired by the octopus: I. From biological functions to artificial requirements.

    Science.gov (United States)

    Margheri, L; Laschi, C; Mazzolai, B

    2012-06-01

    Octopuses are molluscs that belong to the group Cephalopoda. They lack joints and rigid links, and as a result, their arms possess virtually limitless freedom of movement. These flexible appendages exhibit peculiar biomechanical features such as stiffness control, compliance, and high flexibility and dexterity. Studying the capabilities of the octopus arm is a complex task that presents a challenge for both biologists and roboticists, the latter of whom draw inspiration from the octopus in designing novel technologies within soft robotics. With this idea in mind, in this study, we used new, purposively developed methods of analysing the octopus arm in vivo to create new biologically inspired design concepts. Our measurements showed that the octopus arm can elongate by 70% in tandem with a 23% diameter reduction and exhibits an average pulling force of 40 N. The arm also exhibited a 20% mean shortening at a rate of 17.1 mm s(-1) and a longitudinal stiffening rate as high as 2 N (mm s)(-1). Using histology and ultrasounds, we investigated the functional morphology of the internal tissues, including the sinusoidal arrangement of the nerve cord and the local insertion points of the longitudinal and transverse muscle fibres. The resulting information was used to create novel design principles and specifications that can in turn be used in developing a new soft robotic arm.

  9. Soft robotic arm inspired by the octopus: I. From biological functions to artificial requirements

    International Nuclear Information System (INIS)

    Margheri, L; Laschi, C; Mazzolai, B

    2012-01-01

    Octopuses are molluscs that belong to the group Cephalopoda. They lack joints and rigid links, and as a result, their arms possess virtually limitless freedom of movement. These flexible appendages exhibit peculiar biomechanical features such as stiffness control, compliance, and high flexibility and dexterity. Studying the capabilities of the octopus arm is a complex task that presents a challenge for both biologists and roboticists, the latter of whom draw inspiration from the octopus in designing novel technologies within soft robotics. With this idea in mind, in this study, we used new, purposively developed methods of analysing the octopus arm in vivo to create new biologically inspired design concepts. Our measurements showed that the octopus arm can elongate by 70% in tandem with a 23% diameter reduction and exhibits an average pulling force of 40 N. The arm also exhibited a 20% mean shortening at a rate of 17.1 mm s −1 and a longitudinal stiffening rate as high as 2 N (mm s) −1 . Using histology and ultrasounds, we investigated the functional morphology of the internal tissues, including the sinusoidal arrangement of the nerve cord and the local insertion points of the longitudinal and transverse muscle fibres. The resulting information was used to create novel design principles and specifications that can in turn be used in developing a new soft robotic arm. (paper)

  10. 2D-3D radiograph to cone-beam computed tomography (CBCT) registration for C-arm image-guided robotic surgery.

    Science.gov (United States)

    Liu, Wen Pei; Otake, Yoshito; Azizian, Mahdi; Wagner, Oliver J; Sorger, Jonathan M; Armand, Mehran; Taylor, Russell H

    2015-08-01

    C-arm radiographs are commonly used for intraoperative image guidance in surgical interventions. Fluoroscopy is a cost-effective real-time modality, although image quality can vary greatly depending on the target anatomy. Cone-beam computed tomography (CBCT) scans are sometimes available, so 2D-3D registration is needed for intra-procedural guidance. C-arm radiographs were registered to CBCT scans and used for 3D localization of peritumor fiducials during a minimally invasive thoracic intervention with a da Vinci Si robot. Intensity-based 2D-3D registration of intraoperative radiographs to CBCT was performed. The feasible range of X-ray projections achievable by a C-arm positioned around a da Vinci Si surgical robot, configured for robotic wedge resection, was determined using phantom models. Experiments were conducted on synthetic phantoms and animals imaged with an OEC 9600 and a Siemens Artis zeego, representing the spectrum of different C-arm systems currently available for clinical use. The image guidance workflow was feasible using either an optically tracked OEC 9600 or a Siemens Artis zeego C-arm, resulting in an angular difference of Δθ:∼ 30°. The two C-arm systems provided TRE mean ≤ 2.5 mm and TRE mean ≤ 2.0 mm, respectively (i.e., comparable to standard clinical intraoperative navigation systems). C-arm 3D localization from dual 2D-3D registered radiographs was feasible and applicable for intraoperative image guidance during da Vinci robotic thoracic interventions using the proposed workflow. Tissue deformation and in vivo experiments are required before clinical evaluation of this system.

  11. Novel Adaptive Forward Neural MIMO NARX Model for the Identification of Industrial 3-DOF Robot Arm Kinematics

    OpenAIRE

    Ho Pham Huy Anh; Nguyen Thanh Nam

    2012-01-01

    In this paper, a novel forward adaptive neural MIMO NARX model is used for modelling and identifying the forward kinematics of an industrial 3‐DOF robot arm system. The nonlinear features of the forward kinematics of the industrial robot arm drive are thoroughly modelled based on the forward adaptive neural NARX model‐based identification process using experimental input‐output training data. This paper proposes a novel use of a back propagation (BP) algorithm to generate the forward neural M...

  12. A soft body as a reservoir: case studies in a dynamic model of octopus-inspired soft robotic arm

    Science.gov (United States)

    Nakajima, Kohei; Hauser, Helmut; Kang, Rongjie; Guglielmino, Emanuele; Caldwell, Darwin G.; Pfeifer, Rolf

    2013-01-01

    The behaviors of the animals or embodied agents are characterized by the dynamic coupling between the brain, the body, and the environment. This implies that control, which is conventionally thought to be handled by the brain or a controller, can partially be outsourced to the physical body and the interaction with the environment. This idea has been demonstrated in a number of recently constructed robots, in particular from the field of “soft robotics”. Soft robots are made of a soft material introducing high-dimensionality, non-linearity, and elasticity, which often makes the robots difficult to control. Biological systems such as the octopus are mastering their complex bodies in highly sophisticated manners by capitalizing on their body dynamics. We will demonstrate that the structure of the octopus arm cannot only be exploited for generating behavior but also, in a sense, as a computational resource. By using a soft robotic arm inspired by the octopus we show in a number of experiments how control is partially incorporated into the physical arm's dynamics and how the arm's dynamics can be exploited to approximate non-linear dynamical systems and embed non-linear limit cycles. Future application scenarios as well as the implications of the results for the octopus biology are also discussed. PMID:23847526

  13. ARIES NDA Robot operators' manual

    International Nuclear Information System (INIS)

    Scheer, N.L.; Nelson, D.C.

    1998-05-01

    The ARIES NDA Robot is an automation device for servicing the material movements for a suite of Non-destructive assay (NDA) instruments. This suite of instruments includes a calorimeter, a gamma isotopic system, a segmented gamma scanner (SGS), and a neutron coincidence counter (NCC). Objects moved by the robot include sample cans, standard cans, and instrument plugs. The robot computer has an RS-232 connection with the NDA Host computer, which coordinates robot movements and instrument measurements. The instruments are expected to perform measurements under the direction of the Host without operator intervention. This user's manual describes system startup, using the main menu, manual operation, and error recovery

  14. Dual Arm Work Module Development and Appplications

    Energy Technology Data Exchange (ETDEWEB)

    Noakes, M.W.

    1999-04-25

    The dual arm work module (DAWM) was developed at Oak Ridge National Laboratory (ORNL) by the Robotics Technology Development Program (RTDP) as a development test bed to study issues related to dual arm manipulation, including platform cotilguration, controls, automation, operations, and tooling. The original platform was based on two Schilling Titan II manipulators mounted to a 5-degree-of- freedom (DOF) base fabricated by RedZone Robotics, Inc. The 5-DOF articulation provided a center torso rotation, linear actuation to change the separation between the arms, and arm base rotation joints to provide "elbows up," elbows down," or "elbows out" orientation. A series of tests were conducted on operations, tooling, and task space scene analysis (TSSA)-driven robotics for overhead transporter- mounted and crane hook-deployed scenarios. A concept was developed for DAWM deployment from a large remote work vehicle, but the project was redirected to support dismantlement of the Chicago Pile #5 (CP-5) reactor at Argonne National Laboratory in fiscal year (FY) 1997. Support of CP-5 required a change in focus of the dual arm technology from that of a development test bed to a system focussed for a specific end user. ORNL teamed with the Idaho National Environmental ,Engineering Laboratory, Sandia National Laboratory, and the Savannah River Technology Center to deliver a crane-deployed derivative of the DAWM, designated the dual arm work platform (DAWP). RTDP staff supported DAWP at CP-5 for one FY; Argonne staff continued operation through to dismantlement of the reactor internals. Lessons learned from this interaction were extensive. Beginning in FY 1999, dual arm development activities are again being pursued in the context of those lessons learned. This paper describes the progression of philosophy of the DAWM from initial test bed to lessons learned through interaction at CP-5 and to the present investigation of telerobotic assist of teleoperation and TSSA- driven robotics.

  15. Light Duty Utility Arm computer software configuration management plan

    International Nuclear Information System (INIS)

    Philipp, B.L.

    1998-01-01

    This plan describes the configuration management for the Light Duty Utility Arm robotic manipulation arm control software. It identifies the requirement, associated documents, and the software control methodology. The Light Duty Utility Ann (LDUA) System is a multi-axis robotic manipulator arm and deployment vehicle, used to perform surveillance and characterization operations in support of remediation of defense nuclear wastes currently stored in the Hanford Underground Storage Tanks (USTs) through the available 30.5 cm (12 in.) risers. This plan describes the configuration management of the LDUA software

  16. Robot-assisted arm assessments in spinal cord injured patients: a consideration of concept study.

    Directory of Open Access Journals (Sweden)

    Urs Keller

    Full Text Available Robotic assistance is increasingly used in neurological rehabilitation for enhanced training. Furthermore, therapy robots have the potential for accurate assessment of motor function in order to diagnose the patient status, to measure therapy progress or to feedback the movement performance to the patient and therapist in real time. We investigated whether a set of robot-based assessments that encompasses kinematic, kinetic and timing metrics is applicable, safe, reliable and comparable to clinical metrics for measurement of arm motor function. Twenty-four healthy subjects and five patients after spinal cord injury underwent robot-based assessments using the exoskeleton robot ARMin. Five different tasks were performed with aid of a visual display. Ten kinematic, kinetic and timing assessment parameters were extracted on joint- and end-effector level (active and passive range of motion, cubic reaching volume, movement time, distance-path ratio, precision, smoothness, reaction time, joint torques and joint stiffness. For cubic volume, joint torques and the range of motion for most joints, good inter- and intra-rater reliability were found whereas precision, movement time, distance-path ratio and smoothness showed weak to moderate reliability. A comparison with clinical scores revealed good correlations between robot-based joint torques and the Manual Muscle Test. Reaction time and distance-path ratio showed good correlation with the "Graded and Redefined Assessment of Strength, Sensibility and Prehension" (GRASSP and the Van Lieshout Test (VLT for movements towards a predefined position in the center of the frontal plane. In conclusion, the therapy robot ARMin provides a comprehensive set of assessments that are applicable and safe. The first results with spinal cord injured patients and healthy subjects suggest that the measurements are widely reliable and comparable to clinical scales for arm motor function. The methods applied and results can

  17. Using Modeling and Simulation to Predict Operator Performance and Automation-Induced Complacency With Robotic Automation: A Case Study and Empirical Validation.

    Science.gov (United States)

    Wickens, Christopher D; Sebok, Angelia; Li, Huiyang; Sarter, Nadine; Gacy, Andrew M

    2015-09-01

    The aim of this study was to develop and validate a computational model of the automation complacency effect, as operators work on a robotic arm task, supported by three different degrees of automation. Some computational models of complacency in human-automation interaction exist, but those are formed and validated within the context of fairly simplified monitoring failures. This research extends model validation to a much more complex task, so that system designers can establish, without need for human-in-the-loop (HITL) experimentation, merits and shortcomings of different automation degrees. We developed a realistic simulation of a space-based robotic arm task that could be carried out with three different levels of trajectory visualization and execution automation support. Using this simulation, we performed HITL testing. Complacency was induced via several trials of correctly performing automation and then was assessed on trials when automation failed. Following a cognitive task analysis of the robotic arm operation, we developed a multicomponent model of the robotic operator and his or her reliance on automation, based in part on visual scanning. The comparison of model predictions with empirical results revealed that the model accurately predicted routine performance and predicted the responses to these failures after complacency developed. However, the scanning models do not account for the entire attention allocation effects of complacency. Complacency modeling can provide a useful tool for predicting the effects of different types of imperfect automation. The results from this research suggest that focus should be given to supporting situation awareness in automation development. © 2015, Human Factors and Ergonomics Society.

  18. Robotic arm design for a remotely-deployed, in situ waste characterization probe

    International Nuclear Information System (INIS)

    Kress, R.L.; Jansen, J.F.; Haas, J.W.

    1991-01-01

    This paper describes some design considerations for a system which will combine robotics and laser spectroscopy to produce an in situ monitoring system for heterogeneous waste materials. The new system will provide faster, cheaper, safer, and more complete characterization of mixed solids and liquids stored in tanks and drums or buried in pits. A small, fiberoptic multiprobe that performs Raman and fluorescence measurements of wastes composed of a variety of organic and inorganic compounds will be described. Design considerations for a novel sensor platform that positions and stabilizes the multiprobe relative to the sampling point in order to make accurate spectroscopic measurements and deploys the sensor in hazardous environments with minimal risk to workers will be presented. The core of the platform will be a 3-Degrees-Of-Freedom (3-DOF), spherical coordinate end effector equipped with a proximity sensor that compensates for errors introduced by the flexible nature of the support arm. The platform can be adapted to operate the most robotic deployment systems used in hazardous environments. The multisensor probe will be coupled to remote, portable laser spectrometer systems by a fiber-optic bundle. 5 refs

  19. Robotic arm design for a remotely-deployed, in situ waste characterization probe

    International Nuclear Information System (INIS)

    Kress, Reid; Haas, John; Jansen, John

    1992-01-01

    This paper describes some design considerations for a system which will combine robotics and laser spectroscopy to produce an in situ monitoring system for heterogeneous waste materials. The new system will provide faster, cheaper) safer, and more complete characterization of mixed solids and liquids stored in tanks and drums or buried in pits. A small, fiberoptic multiprobe that performs Raman and fluorescence measurements of wastes composed of a variety of organic and inorganic compounds will be described. Design considerations for a novel sensor platform that positions and stabilizes the multiprobe relative to the sampling point in order to male accurate spectroscopic measurements and deploys the sensor in hazardous environments with minimal risk to workers will be presented. The core of (he platform will be a 3-Degrees-Of-Freedom (3-DOF), spherical coordinate end effector equipped with a proximity sensor that compensates for errors introduced by the flexible nature of the support arm. The platform can be adapted to operate with most robotic deployment systems used in hazardous environments. The multisensor probe will be coupled to remote, portable laser spectrometer systems by a fiber-optic bundle. (author)

  20. CONTROL SYSTEM FOR UNMANNED AIRCRAFT EQUIPPED WITH ROBOTICS ARM

    Directory of Open Access Journals (Sweden)

    Alexei A. Margun

    2014-11-01

    Full Text Available The paper deals with the problem of control system synthesis for multi rotational UAV equipped with robotics arm. Control algorithm is proposed based on the method of feedback linearization and synthesis of proportional-differential controller with the real time computation of the inertia tensor and center of mass changes and compensation of the reactive torque generated by the dynamics of the manipulator. Quadrocopter with attached articulated manipulator is selected as a model of the control object. Systems of equations describing the behavior of considered dynamical system are obtained according to the Newton and Euler-Lagrange laws. Expressions are offered, defining the inertia tensor and the position of the system center of mass depending on the current position of the manipulator, and the torque acting on the quadrocopter from the manipulator. Feedback linearization with arm influence compensation on quadrocopter is applied for the resulting nonlinear coupled system. As a result, robot dynamics equations have been converted to a linear stationary system. Converted system control is achieved by a proportional-differential controller. Examined system simulation is done with control method described in the paper and the classical method based on a proportional-differential controller. Simulation results confirm the effectiveness of the proposed approach and demonstrate that the proposed approach provides higher accuracy of the tracking error, than control method by means of proportional-differential regulator.

  1. A three-arm (laparoscopic, hand-assisted, and robotic) matched-case analysis of intraoperative and postoperative outcomes in minimally invasive colorectal surgery.

    Science.gov (United States)

    Patel, Chirag B; Ragupathi, Madhu; Ramos-Valadez, Diego I; Haas, Eric M

    2011-02-01

    Robotic-assisted laparoscopic surgery is an emerging modality in the field of minimally invasive colorectal surgery. However, there is a dearth of data comparing outcomes with other minimally invasive techniques. We present a 3-arm (conventional, hand-assisted, and robotic) matched-case analysis of intraoperative and short-term outcomes in patients undergoing minimally invasive colorectal procedures. Between August 2008 and October 2009, 70 robotic cases of the rectum and rectosigmoid were performed. Thirty of these were organized into triplets with conventional and hand-assisted cases based on the following 6 matching criteria: 1) surgeon; 2) sex; 3) body mass index; 4) operative procedure; 5) pathology; and 6) history of neoadjuvant therapy in malignant cases. Demographics, intraoperative parameters, and postoperative outcomes were assessed. Pathological outcomes were analyzed in malignant cases. Data were stratified by postoperative diagnosis and operative procedure. There was no significant difference in intraoperative complications, estimated blood loss (126.1 ± 98.5 mL overall), or postoperative morbidity and mortality among the groups. Robotic technique required longer operative time compared with conventional laparoscopic (P hand-assisted (P robotic approach results in short-term outcomes comparable to conventional and hand-assisted laparoscopic approaches for benign and malignant diseases of the rectum and rectosigmoid. With 3-dimensional visualization, additional freedom of motion, and improved ergonomics, this enabling technology may play an important role when performing colorectal procedures involving the pelvic anatomy.

  2. ITER Articulated Inspection Arm (AIA): Geometric calibration issues of a long-reach flexible robot

    International Nuclear Information System (INIS)

    Arhur, D.; Perrot, Y.; Bidard, C.; Friconneau, J.P.; Palmer, J.D.; Semeraro, L.

    2005-01-01

    This paper is part of the Remote Handling (RH) activities for the future fusion reactor ITER. Specifically it relates to the possibility to carry out close inspection tasks of the Vacuum Vessel first wall using a long reach robot called the 'Articulated Inspection Arm' (AIA). Early studies for this device identified the need of improving the accuracy of the end-effector position in such robot structures. Therefore, the aim of this R and D program performed under the European Fusion Development Agreement (EFDA) work program is to develop a flexible parametric model with localised compliances of an AIA-like system, in order to compensate for its flexibilities. The geometric calibration is performed using a non-linear multivariable optimisation technique, which minimizes the average error between the simulated and real robot position. The optimised set of parameters, tested on the first segment of the robot, enables to divide by 3 the error on the end-effector position, in comparison to a rigid model. We expect better prediction after mechanical improvements to reduce the serious backlash in the joints. The prediction model applied to the whole arm will enable errors to be reduced from more than 1 m, in some configurations, to a final accuracy of a few centimetres

  3. Automatic Operation For A Robot Lawn Mower

    Science.gov (United States)

    Huang, Y. Y.; Cao, Z. L.; Oh, S. J.; Kattan, E. U.; Hall, E. L.

    1987-02-01

    A domestic mobile robot, lawn mower, which performs the automatic operation mode, has been built up in the Center of Robotics Research, University of Cincinnati. The robot lawn mower automatically completes its work with the region filling operation, a new kind of path planning for mobile robots. Some strategies for region filling of path planning have been developed for a partly-known or a unknown environment. Also, an advanced omnidirectional navigation system and a multisensor-based control system are used in the automatic operation. Research on the robot lawn mower, especially on the region filling of path planning, is significant in industrial and agricultural applications.

  4. Tele-operated service robots : ROSE

    NARCIS (Netherlands)

    Osch, van M.P.W.J.; Bera, D.; Hee, van K.M.; Koks, Y.; Zeegers, H.

    2014-01-01

    Service robots are robots that are intended to perform tasks normally done by humans in an environment in which humans work as well. However, they are neither required to accomplish these tasks in the same way as humans nor need to look like a human being. A tele-operated robot is controlled from a

  5. Robot-laser system

    International Nuclear Information System (INIS)

    Akeel, H.A.

    1987-01-01

    A robot-laser system is described for providing a laser beam at a desired location, the system comprising: a laser beam source; a robot including a plurality of movable parts including a hollow robot arm having a central axis along which the laser source directs the laser beam; at least one mirror for reflecting the laser beam from the source to the desired location, the mirror being mounted within the robot arm to move therewith and relative thereto to about a transverse axis that extends angularly to the central axis of the robot arm; and an automatic programmable control system for automatically moving the mirror about the transverse axis relative to and in synchronization with movement of the robot arm to thereby direct the laser beam to the desired location as the arm is moved

  6. Human-Robot Interaction Directed Research Project

    Science.gov (United States)

    Sandor, Aniko; Cross, Ernest V., II; Chang, Mai Lee

    2014-01-01

    Human-robot interaction (HRI) is a discipline investigating the factors affecting the interactions between humans and robots. It is important to evaluate how the design of interfaces and command modalities affect the human's ability to perform tasks accurately, efficiently, and effectively when working with a robot. By understanding the effects of interface design on human performance, workload, and situation awareness, interfaces can be developed to appropriately support the human in performing tasks with minimal errors and with appropriate interaction time and effort. Thus, the results of research on human-robot interfaces have direct implications for the design of robotic systems. This DRP concentrates on three areas associated with interfaces and command modalities in HRI which are applicable to NASA robot systems: 1) Video Overlays, 2) Camera Views, and 3) Command Modalities. The first study focused on video overlays that investigated how Augmented Reality (AR) symbology can be added to the human-robot interface to improve teleoperation performance. Three types of AR symbology were explored in this study, command guidance (CG), situation guidance (SG), and both (SCG). CG symbology gives operators explicit instructions on what commands to input, whereas SG symbology gives operators implicit cues so that operators can infer the input commands. The combination of CG and SG provided operators with explicit and implicit cues allowing the operator to choose which symbology to utilize. The objective of the study was to understand how AR symbology affects the human operator's ability to align a robot arm to a target using a flight stick and the ability to allocate attention between the symbology and external views of the world. The study evaluated the effects type of symbology (CG and SG) has on operator tasks performance and attention allocation during teleoperation of a robot arm. The second study expanded on the first study by evaluating the effects of the type of

  7. Performance and Usability of Various Robotic Arm Control Modes from Human Force Signals

    Directory of Open Access Journals (Sweden)

    Sébastien Mick

    2017-10-01

    Full Text Available Elaborating an efficient and usable mapping between input commands and output movements is still a key challenge for the design of robotic arm prostheses. In order to address this issue, we present and compare three different control modes, by assessing them in terms of performance as well as general usability. Using an isometric force transducer as the command device, these modes convert the force input signal into either a position or a velocity vector, whose magnitude is linearly or quadratically related to force input magnitude. With the robotic arm from the open source 3D-printed Poppy Humanoid platform simulating a mobile prosthesis, an experiment was carried out with eighteen able-bodied subjects performing a 3-D target-reaching task using each of the three modes. The subjects were given questionnaires to evaluate the quality of their experience with each mode, providing an assessment of their global usability in the context of the task. According to performance metrics and questionnaire results, velocity control modes were found to perform better than position control mode in terms of accuracy and quality of control as well as user satisfaction and comfort. Subjects also seemed to favor quadratic velocity control over linear (proportional velocity control, even if these two modes did not clearly distinguish from one another when it comes to performance and usability assessment. These results highlight the need to take into account user experience as one of the key criteria for the design of control modes intended to operate limb prostheses.

  8. dSPACE real time implementation of fuzzy PID position controller for vertical rotating single link arm robot using four-quadrant BLDC drive

    Directory of Open Access Journals (Sweden)

    Manikandan Ramasamy

    2017-07-01

    Full Text Available Automation has been growing in recent years for the manufacturing industries to increase productivity. Multiple robotic arms are used to handle materials for lifting in flexible directions. The vertical rotation of a 360 degree single arm is considered in this research on a position servo drive with brushless DC motor. The load torque of an arm varies depending upon the angular displacement due to gravity, so it requires four-quadrant operation of the drive with a robust feedback controller. This paper deals with the design and performance comparison of a conventional PID feedback controller with a fuzzy-based PID controller and suggests the most suitable controller. The design was implemented in real time through the dSPACE DS1104 controller environment to verify the dynamic behaviors of the arm.

  9. Robot-assisted reaching exercise promotes arm movement recovery in chronic hemiparetic stroke: a randomized controlled pilot study

    Directory of Open Access Journals (Sweden)

    Rymer W Zev

    2006-06-01

    Full Text Available Abstract Background and purpose Providing active assistance to complete desired arm movements is a common technique in upper extremity rehabilitation after stroke. Such active assistance may improve recovery by affecting somatosensory input, motor planning, spasticity or soft tissue properties, but it is labor intensive and has not been validated in controlled trials. The purpose of this study was to investigate the effects of robotically administered active-assistive exercise and compare those with free reaching voluntary exercise in improving arm movement ability after chronic stroke. Methods Nineteen individuals at least one year post-stroke were randomized into one of two groups. One group performed 24 sessions of active-assistive reaching exercise with a simple robotic device, while a second group performed a task-matched amount of unassisted reaching. The main outcome measures were range and speed of supported arm movement, range, straightness and smoothness of unsupported reaching, and the Rancho Los Amigos Functional Test of Upper Extremity Function. Results and discussion There were significant improvements with training for range of motion and velocity of supported reaching, straightness of unsupported reaching, and functional movement ability. These improvements were not significantly different between the two training groups. The group that performed unassisted reaching exercise improved the smoothness of their reaching movements more than the robot-assisted group. Conclusion Improvements with both forms of exercise confirmed that repeated, task-related voluntary activation of the damaged motor system is a key stimulus to motor recovery following chronic stroke. Robotically assisting in reaching successfully improved arm movement ability, although it did not provide any detectable, additional value beyond the movement practice that occurred concurrently with it. The inability to detect any additional value of robot-assisted reaching

  10. On nonlinear dynamics and control of a robotic arm with chaos

    Directory of Open Access Journals (Sweden)

    Felix J. L. P.

    2014-01-01

    Full Text Available In this paper a robotic arm is modelled by a double pendulum excited in its base by a DC motor of limited power via crank mechanism and elastic connector. In the mathematical model, a chaotic motion was identified, for a wide range of parameters. Controlling of the chaotic behaviour of the system, were implemented using, two control techniques, the nonlinear saturation control (NSC and the optimal linear feedback control (OLFC. The actuator and sensor of the device are allowed in the pivot and joints of the double pendulum. The nonlinear saturation control (NSC is based in the order second differential equations and its action in the pivot/joint of the robotic arm is through of quadratic nonlinearities feedback signals. The optimal linear feedback control (OLFC involves the application of two control signals, a nonlinear feedforward control to maintain the controlled system to a desired periodic orbit, and control a feedback control to bring the trajectory of the system to the desired orbit. Simulation results, including of uncertainties show the feasibility of the both methods, for chaos control of the considered system.

  11. Development of a VR training system of robotic peroral operation procedure for endoscopic surgery of digestive tracts

    International Nuclear Information System (INIS)

    Suzuki, Naoki; Hattori, Asaki; Tanoue, Kazuo; Ieiri, Satoshi; Konishi, Kozo; Tomikawa, Morimasa; Kenmotsu, Hajime; Hashizume, Makoto

    2010-01-01

    This report presents the development of a VR (virtual real) training system of robotic peroral operation procedure for endoscopic resection of gastric mucosa as the training is essential because the procedure differs from usual one hitherto. For VR operation space, used is reporters' sphere-filled organ model (SFM), which is deformed by and repels to, the outside force as a soft tissue rapidly in the real time. The deformation and repellence are computable. The SFM space is reconstructed to 3D of the inner environment of stomach using MRI data. The endoscope has, at the right and left side of its top, 2 arms of inner needle knife-equipped robotic forceps and is inserted perorally for operation. In VR, the forceps can grab the gastric mucosa, cut it with the knife to complete resection and carry the specimen out of the body. For the procedure training, the time required for hemostasis, bleeding volume, trace of the arms, intensity and direction of the outer force given are recorded, with which trainee's safety and degree of skill are evaluable in VR. Hydration step and clipping to close the wound are to be further added in the procedure. (T.T.)

  12. The preliminary of software development for the kinematics analysis of 5 DOF Nuclear Malaysia robot arm v2

    International Nuclear Information System (INIS)

    Mohd Zaid Hassan; Anwar Abdul Rahman; Rosli Darmawan; Mohd Arif Hamzah

    2010-01-01

    This paper presents the preliminary software development for the kinematics analysis of 5 DOF rescue robot. The kinematics analysis is the study of relationship between the individual joints of the robot manipulator, the position and orientation of the end-effector. The Denavit-Hartenberg (DH) model is used to model the robot links and joints. Both forward and inverse kinematic are presented. The simulation software has been developed by using MATLAB to solve the robot arms kinematic behavior. (author)

  13. TU-FG-BRB-11: Design and Evaluation of a Robotic C-Arm CBCT System for Image-Guided Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hua, C; Yao, W; Farr, J; Merchant, T [St. Jude Children’s Research Hospital, Memphis, TN (United States); Kidani, T; Tomida, K; Ozawa, S; Nishimura, T; Fujusawa, T; Shinagawa, R [Hitachi, Ltd., Hitachi-shi, Ibaraki-ken (Japan)

    2016-06-15

    Purpose: To describe the design and performance of a ceiling-mounted robotic C-arm CBCT system for image-guided proton therapy. Methods: Uniquely different from traditional C-arm CBCT used in interventional radiology, the imaging system was designed to provide volumetric image guidance for patients treated on a 190-degree proton gantry system and a 6 degree-of-freedom (DOF) robotic patient positioner. The mounting of robotic arms to the ceiling rails, rather than gantry or nozzle, provides the flexibility in imaging locations (isocenter, iso+27cm in X, iso+100cm in Y) in the room and easier upgrade as technology advances. A kV X-ray tube and a 43×43cm flat panel imager were mounted to a rotating C-ring (87cm diameter), which is coupled to the C-arm concentrically. Both C-arm and the robotic arm remain stationary during imaging to maintain high position accuracy. Source-to-axis distance and source-to-imager distance are 100 and 150cm, respectively. A 14:1 focused anti-scatter grid and a bowtie filer are used for image acquisition. A unique automatic collimator device of 4 independent blades for adjusting field of view and reducing patient dose has also been developed. Results: Sub-millimeter position accuracy and repeatability of the robotic C-arm were measured with a laser tracker. High quality CBCT images for positioning can be acquired with a weighted CTDI of 3.6mGy (head in 200° full fan mode: 100kV, 20mA, 20ms, 10fps)-8.7 mGy (pelvis in 360° half fan mode: 125kV, 42mA, 20ms, 10fps). Image guidance accuracy achieved <1mm (3D vector) with automatic 3D-3D registration for anthropomorphic head and pelvis phantoms. Since November 2015, 22 proton therapy patients have undergone daily CBCT imaging for 6 DOF positioning. Conclusion: Decoupled from gantry and nozzle, this CBCT system provides a unique solution for volumetric image guidance with half/partial proton gantry systems. We demonstrated that daily CBCT can be integrated into proton therapy for pre

  14. TU-FG-BRB-11: Design and Evaluation of a Robotic C-Arm CBCT System for Image-Guided Proton Therapy

    International Nuclear Information System (INIS)

    Hua, C; Yao, W; Farr, J; Merchant, T; Kidani, T; Tomida, K; Ozawa, S; Nishimura, T; Fujusawa, T; Shinagawa, R

    2016-01-01

    Purpose: To describe the design and performance of a ceiling-mounted robotic C-arm CBCT system for image-guided proton therapy. Methods: Uniquely different from traditional C-arm CBCT used in interventional radiology, the imaging system was designed to provide volumetric image guidance for patients treated on a 190-degree proton gantry system and a 6 degree-of-freedom (DOF) robotic patient positioner. The mounting of robotic arms to the ceiling rails, rather than gantry or nozzle, provides the flexibility in imaging locations (isocenter, iso+27cm in X, iso+100cm in Y) in the room and easier upgrade as technology advances. A kV X-ray tube and a 43×43cm flat panel imager were mounted to a rotating C-ring (87cm diameter), which is coupled to the C-arm concentrically. Both C-arm and the robotic arm remain stationary during imaging to maintain high position accuracy. Source-to-axis distance and source-to-imager distance are 100 and 150cm, respectively. A 14:1 focused anti-scatter grid and a bowtie filer are used for image acquisition. A unique automatic collimator device of 4 independent blades for adjusting field of view and reducing patient dose has also been developed. Results: Sub-millimeter position accuracy and repeatability of the robotic C-arm were measured with a laser tracker. High quality CBCT images for positioning can be acquired with a weighted CTDI of 3.6mGy (head in 200° full fan mode: 100kV, 20mA, 20ms, 10fps)-8.7 mGy (pelvis in 360° half fan mode: 125kV, 42mA, 20ms, 10fps). Image guidance accuracy achieved <1mm (3D vector) with automatic 3D-3D registration for anthropomorphic head and pelvis phantoms. Since November 2015, 22 proton therapy patients have undergone daily CBCT imaging for 6 DOF positioning. Conclusion: Decoupled from gantry and nozzle, this CBCT system provides a unique solution for volumetric image guidance with half/partial proton gantry systems. We demonstrated that daily CBCT can be integrated into proton therapy for pre

  15. Autonomous Inspection Robot for Power Transmission Lines Maintenance While Operating on the Overhead Ground Wires

    Directory of Open Access Journals (Sweden)

    Zheng Li

    2010-12-01

    Full Text Available This paper describes the development of a mobile robot capable of clearing such obstacles as counterweights, anchor clamps, and torsion tower. The mobile robot walks on overhead ground wires in 500KV power tower. Its ultimate purpose is to automate to inspect the defect of power transmission line. The robot with 13 motors is composed of two arms, two wheels, two claws, two wrists, etc. Each arm has 4 degree of freedom. Claws are also mounted on the arms. An embedded computer based on PC/104 is chosen as the core of control system. Visible light and thermal infrared cameras are installed to obtain the video and temperature information, and the communication system is based on wireless LAN TCP/IP protocol. A prototype robot was developed with careful considerations of mobility. The new sensor configuration is used for the claw to grasp the overhead ground wires. The bridge is installed in the torsion tower for the robot easy to cross obstacles. The new posture plan is proposed for obstacles cleaning in the torsion tower. Results of experiments demonstrate that the robot can be applied to execute the navigation and inspection tasks.

  16. Autonomous Inspection Robot for Power Transmission Lines Maintenance While Operating on the Overhead Ground Wires

    Directory of Open Access Journals (Sweden)

    Zheng Li

    2011-01-01

    Full Text Available This paper describes the development of a mobile robot capable of clearing such obstacles as counterweights, anchor clamps, and torsion tower. The mobile robot walks on overhead ground wires in 500KV power tower. Its ultimate purpose is to automate to inspect the defect of power transmission line. The robot with 13 motors is composed of two arms, two wheels, two claws, two wrists, etc. Each arm has 4 degree of freedom. Claws are also mounted on the arms. An embedded computer based on PC/104 is chosen as the core of control system. Visible light and thermal infrared cameras are installed to obtain the video and temperature information, and the communication system is based on wireless LAN TCP/IP protocol. A prototype robot was developed with careful considerations of mobility. The new sensor configuration is used for the claw to grasp the overhead ground wires. The bridge is installed in the torsion tower for the robot easy to cross obstacles. The new posture plan is proposed for obstacles cleaning in the torsion tower. Results of experiments demonstrate that the robot can be applied to execute the navigation and inspection tasks.

  17. Multi-Robot Assembly Strategies and Metrics

    Science.gov (United States)

    MARVEL, JEREMY A.; BOSTELMAN, ROGER; FALCO, JOE

    2018-01-01

    We present a survey of multi-robot assembly applications and methods and describe trends and general insights into the multi-robot assembly problem for industrial applications. We focus on fixtureless assembly strategies featuring two or more robotic systems. Such robotic systems include industrial robot arms, dexterous robotic hands, and autonomous mobile platforms, such as automated guided vehicles. In this survey, we identify the types of assemblies that are enabled by utilizing multiple robots, the algorithms that synchronize the motions of the robots to complete the assembly operations, and the metrics used to assess the quality and performance of the assemblies. PMID:29497234

  18. Multi-Robot Assembly Strategies and Metrics.

    Science.gov (United States)

    Marvel, Jeremy A; Bostelman, Roger; Falco, Joe

    2018-02-01

    We present a survey of multi-robot assembly applications and methods and describe trends and general insights into the multi-robot assembly problem for industrial applications. We focus on fixtureless assembly strategies featuring two or more robotic systems. Such robotic systems include industrial robot arms, dexterous robotic hands, and autonomous mobile platforms, such as automated guided vehicles. In this survey, we identify the types of assemblies that are enabled by utilizing multiple robots, the algorithms that synchronize the motions of the robots to complete the assembly operations, and the metrics used to assess the quality and performance of the assemblies.

  19. Conceptual design main progress of EAST Articulated Maintenance Arm (EAMA) system

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Shanshuang, E-mail: shiss@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Laboratory of Intelligent Machines, Lappeenranta University of Technology (Finland); Song, Yuntao; Cheng, Yong [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Villedieu, Eric; Bruno, Vincent [CEA-IRFM, F-13108 Saint-Paul-Lez-Durance (France); Feng, Hansheng [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Wu, Huapeng [Laboratory of Intelligent Machines, Lappeenranta University of Technology (Finland); Wang, Peng [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Hao, Zhiwei; Li, Yang; Wang, Kun; Pan, Hongtao [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2016-03-15

    Highlights: • EAST Articulated Maintenance Arm (EAMA) system is being collaboratively developed by ASIPP and CEA-IRFM. • Conceptual design for a 3-DOF wrist end effector with gripper has been finished. • Kinematic design can reach 90% of the workspace inside EAST tokamak vessel. • A prototype of EAMA arm segment has been built to validate the design. - Abstract: EAST articulated maintenance arm (EAMA) system is being collaboratively developed by ASIPP and CEA-IRFM for the purpose of remote inspection and simple maintenance operations in EAST vacuum vessel during physical experiments without breaking the ultra-high vacuum condition. The EAMA system design is based on a similar articulated inspection arm robot successfully demonstrated in Tore Supra in 2008. In order to better meet EAST configurations and maintenance requirements, optimized mechanisms and dimensions are considered for EAMA robot as upgrades. Besides, the segmented arm is equipped with a 3-DOF wrist end effector and gripper for gripping operation as well as inspection. Some calculations and simulations on statics, kinematics and workspace of EAMA have been presented to validate the feasibility. This paper introduces the overall design of the EAMA robot and presents implementation progress.

  20. Conceptual design main progress of EAST Articulated Maintenance Arm (EAMA) system

    International Nuclear Information System (INIS)

    Shi, Shanshuang; Song, Yuntao; Cheng, Yong; Villedieu, Eric; Bruno, Vincent; Feng, Hansheng; Wu, Huapeng; Wang, Peng; Hao, Zhiwei; Li, Yang; Wang, Kun; Pan, Hongtao

    2016-01-01

    Highlights: • EAST Articulated Maintenance Arm (EAMA) system is being collaboratively developed by ASIPP and CEA-IRFM. • Conceptual design for a 3-DOF wrist end effector with gripper has been finished. • Kinematic design can reach 90% of the workspace inside EAST tokamak vessel. • A prototype of EAMA arm segment has been built to validate the design. - Abstract: EAST articulated maintenance arm (EAMA) system is being collaboratively developed by ASIPP and CEA-IRFM for the purpose of remote inspection and simple maintenance operations in EAST vacuum vessel during physical experiments without breaking the ultra-high vacuum condition. The EAMA system design is based on a similar articulated inspection arm robot successfully demonstrated in Tore Supra in 2008. In order to better meet EAST configurations and maintenance requirements, optimized mechanisms and dimensions are considered for EAMA robot as upgrades. Besides, the segmented arm is equipped with a 3-DOF wrist end effector and gripper for gripping operation as well as inspection. Some calculations and simulations on statics, kinematics and workspace of EAMA have been presented to validate the feasibility. This paper introduces the overall design of the EAMA robot and presents implementation progress.

  1. WORKSPACE DRAWING FROM A MANIPULATOR ARM WITH 6 DOF

    Directory of Open Access Journals (Sweden)

    NAIDIN Gigi

    2011-06-01

    Full Text Available Modelling and simulation is an important aspect in robotic field. Knowing of the workspace is very important to the operation of manipulators arm. This paper investigates operational performance of space manipulator arm destined for industrial manufacturing, by defining and analyzing their workspace and manipulability measure. The authors show that manipulator arm developing requires the consideration of more efficient dynamic models and use of dedicated processing techniques such as Autodesk-Inventor 9, MATLAB, WorkSpace software.

  2. The Human-Robot Interaction Operating System

    Science.gov (United States)

    Fong, Terrence; Kunz, Clayton; Hiatt, Laura M.; Bugajska, Magda

    2006-01-01

    In order for humans and robots to work effectively together, they need to be able to converse about abilities, goals and achievements. Thus, we are developing an interaction infrastructure called the "Human-Robot Interaction Operating System" (HRI/OS). The HRI/OS provides a structured software framework for building human-robot teams, supports a variety of user interfaces, enables humans and robots to engage in task-oriented dialogue, and facilitates integration of robots through an extensible API.

  3. Controlling Flexible Robot Arms Using High Speed Dynamics Process

    Science.gov (United States)

    Jain, Abhinandan (Inventor)

    1996-01-01

    A robot manipulator controller for a flexible manipulator arm having plural bodies connected at respective movable hinges and flexible in plural deformation modes corresponding to respective modal spatial influence vectors relating deformations of plural spaced nodes of respective bodies to the plural deformation modes, operates by computing articulated body quantities for each of the bodies from respective modal spatial influence vectors, obtaining specified body forces for each of the bodies, and computing modal deformation accelerations of the nodes and hinge accelerations of the hinges from the specified body forces, from the articulated body quantities and from the modal spatial influence vectors. In one embodiment of the invention, the controller further operates by comparing the accelerations thus computed to desired manipulator motion to determine a motion discrepancy, and correcting the specified body forces so as to reduce the motion discrepancy. The manipulator bodies and hinges are characterized by respective vectors of deformation and hinge configuration variables, and computing modal deformation accelerations and hinge accelerations is carried out for each one of the bodies beginning with the outermost body by computing a residual body force from a residual body force of a previous body and from the vector of deformation and hinge configuration variables, computing a resultant hinge acceleration from the body force, the residual body force and the articulated hinge inertia, and revising the residual body force modal body acceleration.

  4. Effects of intensive arm training with the rehabilitation robot ARMin II in chronic stroke patients: four single-cases

    Directory of Open Access Journals (Sweden)

    Nef Tobias

    2009-12-01

    Full Text Available Abstract Background Robot-assisted therapy offers a promising approach to neurorehabilitation, particularly for severely to moderately impaired stroke patients. The objective of this study was to investigate the effects of intensive arm training on motor performance in four chronic stroke patients using the robot ARMin II. Methods ARMin II is an exoskeleton robot with six degrees of freedom (DOF moving shoulder, elbow and wrist joints. Four volunteers with chronic (≥ 12 months post-stroke left side hemi-paresis and different levels of motor severity were enrolled in the study. They received robot-assisted therapy over a period of eight weeks, three to four therapy sessions per week, each session of one hour. Patients 1 and 4 had four one-hour training sessions per week and patients 2 and 3 had three one-hour training sessions per week. Primary outcome variable was the Fugl-Meyer Score of the upper extremity Assessment (FMA, secondary outcomes were the Wolf Motor Function Test (WMFT, the Catherine Bergego Scale (CBS, the Maximal Voluntary Torques (MVTs and a questionnaire about ADL-tasks, progress, changes, motivation etc. Results Three out of four patients showed significant improvements (p Conclusion Data clearly indicate that intensive arm therapy with the robot ARMin II can significantly improve motor function of the paretic arm in some stroke patients, even those in a chronic state. The findings of the study provide a basis for a subsequent controlled randomized clinical trial.

  5. Application of robotics in general surgery: initial experience.

    Science.gov (United States)

    Nguyen, Ninh T; Hinojosa, Marcelo W; Finley, David; Stevens, Melinda; Paya, Mahbod

    2004-10-01

    Robotic surgery was recently approved for clinical use in general abdominal surgery. The aim of this study was to review our experience with the da Vinci surgical system during laparoscopic general surgical procedures. Eighteen patients underwent robotically assisted laparoscopic abdominal surgery between June 2002 and March 2003. Main outcome measures were operative time, room setup time, robotic arm-positioning and surgical time, blood loss, conversion to laparoscopy, length of stay, and morbidity. The types of robotically assisted laparoscopic procedures were excision of gastric leiomyoma (n = 1), Heller myotomy (n = 1), cholecystectomy (n = 2), gastric banding (n = 2), Nissen fundoplication (n = 4), and gastric bypass (n = 8). The mean room setup time was 63 +/- 14 minutes, and the mean robotic arm-positioning time was 16 +/- 7 minutes. Conversion to laparoscopy occurred in two (11%) of 18 cases because of equipment difficulty (n = 1) and technical difficulty (n = 1). Estimated blood loss was 91 +/- 71 mL. The mean operative time was 156 +/- 42 minutes, and the robotic operative time was 27% of the total operative time. The mean length of hospital stay was 2.2 +/- 1.5 days. There was one postoperative wound infection and one anastomotic stricture. Robotically assisted laparoscopic abdominal surgery is feasible and safe; however, the theoretical advantages of the da Vinci surgical system were not clinically apparent.

  6. Robotically facilitated virtual rehabilitation of arm transport integrated with finger movement in persons with hemiparesis

    OpenAIRE

    Davidow Amy; Lafond Ian; Saleh Soha; Qiu Qinyin; Fluet Gerard G; Merians Alma S; Adamovich Sergei V

    2011-01-01

    Abstract Background Recovery of upper extremity function is particularly recalcitrant to successful rehabilitation. Robotic-assisted arm training devices integrated with virtual targets or complex virtual reality gaming simulations are being developed to deal with this problem. Neural control mechanisms indicate that reaching and hand-object manipulation are interdependent, suggesting that training on tasks requiring coordinated effort of both the upper arm and hand may be a more effective me...

  7. Apparatus and method for modifying the operation of a robotic vehicle in a real environment, to emulate the operation of the robotic vehicle operating in a mixed reality environment

    Science.gov (United States)

    Garretson, Justin R [Albuquerque, NM; Parker, Eric P [Albuquerque, NM; Gladwell, T Scott [Albuquerque, NM; Rigdon, J Brian [Edgewood, NM; Oppel, III, Fred J.

    2012-05-29

    Apparatus and methods for modifying the operation of a robotic vehicle in a real environment to emulate the operation of the robotic vehicle in a mixed reality environment include a vehicle sensing system having a communications module attached to the robotic vehicle for communicating operating parameters related to the robotic vehicle in a real environment to a simulation controller for simulating the operation of the robotic vehicle in a mixed (live, virtual and constructive) environment wherein the affects of virtual and constructive entities on the operation of the robotic vehicle (and vice versa) are simulated. These effects are communicated to the vehicle sensing system which generates a modified control command for the robotic vehicle including the effects of virtual and constructive entities, causing the robot in the real environment to behave as if virtual and constructive entities existed in the real environment.

  8. Conceptual design and kinematic analysis of a novel parallel robot for high-speed pick-and-place operations

    Science.gov (United States)

    Meng, Qizhi; Xie, Fugui; Liu, Xin-Jun

    2018-06-01

    This paper deals with the conceptual design, kinematic analysis and workspace identification of a novel four degrees-of-freedom (DOFs) high-speed spatial parallel robot for pick-and-place operations. The proposed spatial parallel robot consists of a base, four arms and a 1½ mobile platform. The mobile platform is a major innovation that avoids output singularity and offers the advantages of both single and double platforms. To investigate the characteristics of the robot's DOFs, a line graph method based on Grassmann line geometry is adopted in mobility analysis. In addition, the inverse kinematics is derived, and the constraint conditions to identify the correct solution are also provided. On the basis of the proposed concept, the workspace of the robot is identified using a set of presupposed parameters by taking input and output transmission index as the performance evaluation criteria.

  9. Designing, Fabrication and Controlling Of Multipurpose3-DOF Robotic Arm

    Science.gov (United States)

    Nabeel, Hafiz Muhammad; Azher, Anum; Usman Ali, Syed M.; Wahab Mughal, Abdul

    2013-12-01

    In the present work, we have successfully designed and developed a 3-DOF articulated Robotic Arm capable of performing typical industrial tasks such as painting or spraying, assembling and handling automobiles parts and etc., in resemblance to a human arm. The mechanical assembly is designed on SOLIDWORKS and aluminum grade 6061 -T6 is used for its fabrication in order to reduce the structure weight. We have applied inverse kinematics to determine the joint angles, equations are fed into an efficient microcontroller ATMEGA16 which performs all the calculations to determine the joint angles on the basis of given coordinates to actuate the joints through motorized control. Good accuracy was obtained with quadrature optical encoders installed in each joint to achieve the desired position and a LabVIEW based GUI is designed to provide human machine interface.

  10. Designing, Fabrication and Controlling Of Multipurpose3-DOF Robotic Arm

    International Nuclear Information System (INIS)

    Nabeel, Hafiz Muhammad; Azher, Anum; Ali, Syed M Usman; Mughal, Abdul Wahab

    2013-01-01

    In the present work, we have successfully designed and developed a 3-DOF articulated Robotic Arm capable of performing typical industrial tasks such as painting or spraying, assembling and handling automobiles parts and etc., in resemblance to a human arm. The mechanical assembly is designed on SOLIDWORKS and aluminum grade 6061 -T6 is used for its fabrication in order to reduce the structure weight. We have applied inverse kinematics to determine the joint angles, equations are fed into an efficient microcontroller ATMEGA16 which performs all the calculations to determine the joint angles on the basis of given coordinates to actuate the joints through motorized control. Good accuracy was obtained with quadrature optical encoders installed in each joint to achieve the desired position and a LabVIEW based GUI is designed to provide human machine interface

  11. Implementation and Reconfiguration of Robot Operating System on Human Follower Transporter Robot

    Directory of Open Access Journals (Sweden)

    Addythia Saphala

    2015-10-01

    Full Text Available Robotic Operation System (ROS is an im- portant platform to develop robot applications. One area of applications is for development of a Human Follower Transporter Robot (HFTR, which  can  be  considered  as a custom mobile robot utilizing differential driver steering method and equipped with Kinect sensor. This study discusses the development of the robot navigation system by implementing Simultaneous Localization and Mapping (SLAM.

  12. Future of robotic surgery in urology.

    Science.gov (United States)

    Rassweiler, Jens J; Autorino, Riccardo; Klein, Jan; Mottrie, Alex; Goezen, Ali Serdar; Stolzenburg, Jens-Uwe; Rha, Koon H; Schurr, Marc; Kaouk, Jihad; Patel, Vipul; Dasgupta, Prokar; Liatsikos, Evangelos

    2017-12-01

    To provide a comprehensive overview of the current status of the field of robotic systems for urological surgery and discuss future perspectives. A non-systematic literature review was performed using PubMed/Medline search electronic engines. Existing patents for robotic devices were researched using the Google search engine. Findings were also critically analysed taking into account the personal experience of the authors. The relevant patents for the first generation of the da Vinci platform will expire in 2019. New robotic systems are coming onto the stage. These can be classified according to type of console, arrangement of robotic arms, handles and instruments, and other specific features (haptic feedback, eye-tracking). The Telelap ALF-X robot uses an open console with eye-tracking, laparoscopy-like handles with haptic feedback, and arms mounted on separate carts; first clinical trials with this system were reported in 2016. The Medtronic robot provides an open console using three-dimensional high-definition video technology and three arms. The Avatera robot features a closed console with microscope-like oculars, four arms arranged on one cart, and 5-mm instruments with six degrees of freedom. The REVO-I consists of an open console and a four-arm arrangement on one cart; the first experiments with this system were published in 2016. Medicaroid uses a semi-open console and three robot arms attached to the operating table. Clinical trials of the SP 1098-platform using the da Vinci Xi for console-based single-port surgery were reported in 2015. The SPORT robot has been tested in animal experiments for single-port surgery. The SurgiBot represents a bedside solution for single-port surgery providing flexible tube-guided instruments. The Avicenna Roboflex has been developed for robotic flexible ureteroscopy, with promising early clinical results. Several console-based robots for laparoscopic multi- and single-port surgery are expected to come to market within the

  13. Collision avoidance during teleoperation using whole arm proximity sensors coupled to a virtual environment

    International Nuclear Information System (INIS)

    Novak, J.L.; Feddema, J.T.; Miner, N.E.; Stansfield, S.A.

    1993-01-01

    Much of the current robotics effort at the US DOE is directed toward remote handling of hazardous waste. Telerobotic systems are being developed to remotely inspect, characterize, and process waste. This paper describes a collision avoidance system using Whole Arm Proximity (WHAP) sensors on an articulated robot arm. The capacitance-based sensors generate electric fields which completely encompass the robot arm and detect obstacles as they approach from any direction. The robot is moved through the workspace using a velocity command generated either by an operator through a force-sensing input device or a preprogrammed sequence of motions. The directional obstacle information gathered by the WHAP sensors is then used in a matrix column maximization algorithm that automatically selects the sensor closest to an obstacle during each robot controller cycle. The distance from this sensor to the obstacle is used to reduce the component of the command input velocity along the normal axis of the sensor, allowing graceful perturbation of the velocity command to prevent a collision. By scaling only the component of the velocity vector in the direction of the nearest obstacle, the control system restricts motion in the direction of an obstacle while permitting unconstrained motion in other directions. The actual robot joint positions and the WHAP sensor readings are communicated to an operator interface consisting of a graphical model of the Puma robot and its environment. Circles are placed on the graphical robot surface at positions corresponding to the locations of the WHAP sensor. As the individual sensors detect obstacles, the associated circles change color, providing the operator with visual feedback as to the location and relative size of the obstacle. At the same time, the graphical robot position is updated to reflect the actual state of the robot. This information permits the operator to plan alternative paths around unmodeled, but sensed, obstacles

  14. [Robot-aided training in rehabilitation].

    Science.gov (United States)

    Hachisuka, Kenji

    2010-02-01

    Recently, new training techniques that involve the use of robots have been used in the rehabilitation of patients with hemiplegia and paraplegia. Robots used for training the arm include the MIT-MANUS, Arm Trainer, mirror-image motion enabler (MIME) robot, and the assisted rehabilitation and measurement (ARM) Guide. Robots that are used for lower-limb training are the Rehabot, Gait Trainer, Lokomat, LOPES Exoskeleton Robot, and Gait Assist Robot. Robot-aided therapy has enabled the functional training of the arm and the lower limbs in an effective, easy, and comfortable manner. Therefore, with this type of therapy, the patients can repeatedly undergo sufficient and accurate training for a prolonged period. However, evidence of the benefits of robot-aided training has not yet been established.

  15. LARM PKM solutions for torso design in humanoid robots

    Science.gov (United States)

    Ceccarelli, Marco

    2014-12-01

    Human-like torso features are essential in humanoid robots. In this paper problems for design and operation of solutions for a robotic torso are discussed by referring to experiences and designs that have been developed at Laboratory of Robotics and Mechatronics (LARM) in Cassino, Italy. A new solution is presented with conceptual views as waist-trunk structure that makes a proper partition of the performance for walking and arm operations as sustained by a torso.

  16. An automated robot arm system for small animal tissue biopsy under dual-image modality

    International Nuclear Information System (INIS)

    Huang, Y.H.; Wu, T.H.; Lin, M.H.; Yang, C.C.; Guo, W.Y.; Wang, Z.J.; Chen, C.L.; Lee, J.S.

    2006-01-01

    The ability to non-invasively monitor cell biology in vivo is one of the most important goals of molecular imaging. Imaging procedures could be inter-subject performed repeatedly at different investigating stages; thereby need not sacrifice small animals during the entire study period. Thus, the ultimate goal of this study was to design a stereotactic image-guided system for small animals and integrated it with an automatic robot arm for in vivo tissue biopsy analysis. The system was composed of three main parts, including one small animal stereotactic frame, one imaging-fusion software and an automatic robot arm system. The system has been thoroughly evaluated with three components; the robot position accuracy was 0.05±0.02 mm, the image registration accuracy was 0.37±0.18 mm and the system integration was satisfactorily within 1.20±0.39 mm of error. From these results, the system demonstrated sufficient accuracy to guide the micro-injector from the planned delivery routes into practice. The entire system accuracy was limited by the image fusion and orientation procedures, due to its nature of the blurred PET imaging obtained from the small objects. The primary improvement is to acquire as higher resolution as possible the fused imaging for localizing the targets in the future

  17. Control technologies for quadruped walking robot to facilitate carrying operations in reactor buildings

    International Nuclear Information System (INIS)

    Suganuma, Naotaka; Uehara, Takuya; Nakamura, Norihito

    2014-01-01

    At the Fukushima Daiichi Nuclear Power Station of Tokyo Electric Power Co., Inc., which was seriously damaged by the Great East Japan Earthquake of March 11, 2011, it has been difficult for workers to approach the reactor buildings due to the hazardous surrounding environment. The need has therefore arsen for remote-controlled robots to facilitate inspection and restoration work on behalf of workers in such a high-level radiation environment. Toshiba has developed a quadruped walking robot that can carry various tools for decommissioning work. This robot is capable of maintaining its balance while walking on uneven surfaces, slopes, and stairs due to the adoption of control technologies to not only autonomously determine the leg trajectories and center of gravity, but also to correct the leg landing positions and posture with operator intervention according to the walking situation. It also offers high mobility and workability through a manipulation function that allows it to unload tools carried on its back storage area by using two of its legs like arms. This quadruped walking robot was applied to the investigation of suspected water leakage areas in the reactor building of Fukushima Daiichi Nuclear Power Station Unit 2 in December 2012. (author)

  18. A statically balanced and bi-stable compliant end effector combined with a laparoscopic 2DoF robotic arm

    NARCIS (Netherlands)

    Lassooij, J.; Tolou, N.; Tortora, G.; Caccavaro, S.; Menciassi, A.; Herder, J.L.

    2012-01-01

    This article presents the design of a newly developed 2DoF robotic arm with a novel statically balanced and bi-stable compliant grasper as the end effector for laparoscopic surgery application. The arm is based on internal motors actuating 2 rotational DoFs: pitch and roll. The positive stiffness of

  19. Robotically facilitated virtual rehabilitation of arm transport integrated with finger movement in persons with hemiparesis.

    Science.gov (United States)

    Merians, Alma S; Fluet, Gerard G; Qiu, Qinyin; Saleh, Soha; Lafond, Ian; Davidow, Amy; Adamovich, Sergei V

    2011-05-16

    Recovery of upper extremity function is particularly recalcitrant to successful rehabilitation. Robotic-assisted arm training devices integrated with virtual targets or complex virtual reality gaming simulations are being developed to deal with this problem. Neural control mechanisms indicate that reaching and hand-object manipulation are interdependent, suggesting that training on tasks requiring coordinated effort of both the upper arm and hand may be a more effective method for improving recovery of real world function. However, most robotic therapies have focused on training the proximal, rather than distal effectors of the upper extremity. This paper describes the effects of robotically-assisted, integrated upper extremity training. Twelve subjects post-stroke were trained for eight days on four upper extremity gaming simulations using adaptive robots during 2-3 hour sessions. The subjects demonstrated improved proximal stability, smoothness and efficiency of the movement path. This was in concert with improvement in the distal kinematic measures of finger individuation and improved speed. Importantly, these changes were accompanied by a robust 16-second decrease in overall time in the Wolf Motor Function Test and a 24-second decrease in the Jebsen Test of Hand Function. Complex gaming simulations interfaced with adaptive robots requiring integrated control of shoulder, elbow, forearm, wrist and finger movements appear to have a substantial effect on improving hemiparetic hand function. We believe that the magnitude of the changes and the stability of the patient's function prior to training, along with maintenance of several aspects of the gains demonstrated at retention make a compelling argument for this approach to training.

  20. Virtual modeling of robot-assisted manipulations in abdominal surgery.

    Science.gov (United States)

    Berelavichus, Stanislav V; Karmazanovsky, Grigory G; Shirokov, Vadim S; Kubyshkin, Valeriy A; Kriger, Andrey G; Kondratyev, Evgeny V; Zakharova, Olga P

    2012-06-27

    To determine the effectiveness of using multidetector computed tomography (MDCT) data in preoperative planning of robot-assisted surgery. Fourteen patients indicated for surgery underwent MDCT using 64 and 256-slice MDCT. Before the examination, a specially constructed navigation net was placed on the patient's anterior abdominal wall. Processing of MDCT data was performed on a Brilliance Workspace 4 (Philips). Virtual vectors that imitate robotic and assistant ports were placed on the anterior abdominal wall of the 3D model of the patient, considering the individual anatomy of the patient and the technical capabilities of robotic arms. Sites for location of the ports were directed by projection on the roentgen-positive tags of the navigation net. There were no complications observed during surgery or in the post-operative period. We were able to reduce robotic arm interference during surgery. The surgical area was optimal for robotic and assistant manipulators without any need for reinstallation of the trocars. This method allows modeling of the main steps in robot-assisted intervention, optimizing operation of the manipulator and lowering the risk of injuries to internal organs.

  1. Coordinate transformations, orthographic projections, and robot kinematics

    International Nuclear Information System (INIS)

    Crochetiere, W.J.

    1984-01-01

    Humans do not consciously think of moving each of their joints while they move their hands from one place to another. Likewise, robot arms can be commanded to move about in cartesian space without the need to address the individual joints. To do this, the direct and inverse kinematic equations of any robot arm must be derived. The direct kinematic equations uniquely transform the joint positions into the position (and orientation) of the hand, whereas the inverse kinematic equations transform the position (and orientation) of the hand into joint positions. The derivation of the inverse kinematic equations for any particular robot is a difficult problem which may have more than one solution. In this paper, these equations are derived for a six degree of freedom robot arm. A combination of matrix operations to perform coordinate rotations, and trigonometry within the appropriate orthographic projects to perform coordinate translations is employed. This complementary approach yields a solution which is more easily obtained, and also more easily visualized. The resulting solution was programmed into a real-time computer as a part of a higher level software system to control the motion of the arm

  2. An Adaptive Approach for Precise Underwater Vehicle Control in Combined Robot-Diver Operations

    Science.gov (United States)

    2015-03-01

    and Nicosia and Tomei [13] focused on industrial applications involving robotic manipulator arms carrying various loads. The application of...1987. 94 [13] S. Nicosia and P. Tomei, “Model reference adaptive control algorithms for industrial robots ,” Automatica, vol. 20, pp. 635–644, 9... kinematic and dynamic properties,” The International Journal of Robotics Research, vol. 25, pp. 283–296, March 01, 2006. [17] A. Sanei and M. French

  3. A Soft Body as a Reservoir: Case Studies in a Dynamic Model of Octopus-Inspired Soft Robotic Arm

    Directory of Open Access Journals (Sweden)

    Kohei eNakajima

    2013-07-01

    Full Text Available The behaviors of the animals or embodied agents are characterized by the dynamic coupling between the brain, the body, and the environment. This implies that control, which is conventionally thought to be handled by the brain or a controller, can partially be outsourced to the physical body and the interaction with the environment. This idea has been demonstrated in a number of recently constructed robots, in particular from the field of soft robotics. Soft robots are made of a soft material introducing high-dimensionality, nonlinearity, and elasticity, which often makes the robots difficult to control. Biological systems such as the octopus are mastering their complex bodies in highly sophisticated manners by capitalizing on their body dynamics. We will demonstrate that the structure of the octopus arm cannot only be exploited for generating behavior but also, in a sense, as a computational resource. By using a soft robotic arm inspired by the octopus we show in a number of experiments how control is partially incorporated into the physical arm’s dynamics and how the arm’s dynamics can be exploited to approximate nonlinear dynamical systems and embed nonlinear limit cycles. Future application scenarios as well as the implications of the results for the octopus biology are also discussed.

  4. Impact of robotic operative efficiency on profitability.

    Science.gov (United States)

    Geller, Elizabeth J; Matthews, Catherine A

    2013-07-01

    We sought to determine the impact of robotic operative efficiency on profitability and assess the impact of secondary variables. Financial data were collected for all robotic cases performed for fiscal years 2010 (FY10) and 2011 (FY11) at University of North Carolina at Chapel Hill, and included 9 surgical subspecialties. Profitability was defined as a positive operating income. From July 2009 through June 2011, 1295 robotic cases were performed. Robotic surgery was profitable in both fiscal years, with an operating income of $386,735 in FY10 and $822,996 in FY11. In FY10, urogynecology and pediatric surgery were the only nonprofitable subspecialties. In FY11, all subspecialties were profitable. Profitability was associated with case time, payor mix, and procedure type (all P profitability regardless of surgical specialty. Copyright © 2013 Mosby, Inc. All rights reserved.

  5. Controlling flexible robot arms using a high speed dynamics process

    Science.gov (United States)

    Jain, Abhinandan (Inventor); Rodriguez, Guillermo (Inventor)

    1992-01-01

    Described here is a robot controller for a flexible manipulator arm having plural bodies connected at respective movable hinges, and flexible in plural deformation modes. It is operated by computing articulated body qualities for each of the bodies from the respective modal spatial influence vectors, obtaining specified body forces for each of the bodies, and computing modal deformation accelerations of the nodes and hinge accelerations of the hinges from the specified body forces, from the articulated body quantities and from the modal spatial influence vectors. In one embodiment of the invention, the controller further operates by comparing the accelerations thus computed to desired manipulator motion to determine a motion discrepancy, and correcting the specified body forces so as to reduce the motion discrepancy. The manipulator bodies and hinges are characterized by respective vectors of deformation and hinge configuration variables. Computing modal deformation accelerations and hinge accelerations is carried out for each of the bodies, beginning with the outermost body by computing a residual body force from a residual body force of a previous body, computing a resultant hinge acceleration from the body force, and then, for each one of the bodies beginning with the innermost body, computing a modal body acceleration from a modal body acceleration of a previous body, computing a modal deformation acceleration and hinge acceleration from the resulting hinge acceleration and from the modal body acceleration.

  6. Assistant Personal Robot (APR: Conception and Application of a Tele-Operated Assisted Living Robot

    Directory of Open Access Journals (Sweden)

    Eduard Clotet

    2016-04-01

    Full Text Available This paper presents the technical description, mechanical design, electronic components, software implementation and possible applications of a tele-operated mobile robot designed as an assisted living tool. This robotic concept has been named Assistant Personal Robot (or APR for short and has been designed as a remotely telecontrolled robotic platform built to provide social and assistive services to elderly people and those with impaired mobility. The APR features a fast high-mobility motion system adapted for tele-operation in plain indoor areas, which incorporates a high-priority collision avoidance procedure. This paper presents the mechanical architecture, electrical fundaments and software implementation required in order to develop the main functionalities of an assistive robot. The APR uses a tablet in order to implement the basic peer-to-peer videoconference and tele-operation control combined with a tactile graphic user interface. The paper also presents the development of some applications proposed in the framework of an assisted living robot.

  7. Optimization-based motion generation for multiped robots in contact scenarios

    OpenAIRE

    Herzog, Alexander

    2017-01-01

    The introduction of legged robots into society has the potential to impact many aspects of our lives. The versatile morphology of robots with arms and legs, or multipeds, allows them to operate in a broad spectrum of environments. For example, legged robots could assist at construction sites or locomote in rocky terrain under persistent interaction with the environment through contact. These behaviors require algorithms that translate high level operator commands into movement and contact int...

  8. Integración del brazo robot IRB120 en entorno ROS-MATLAB

    OpenAIRE

    Gómez Cuadrado, José Manuel

    2017-01-01

    Este proyecto usa el entorno ROS (Robot Operating System) para desarrollar el control del brazo robot IRB 120 y su implementación en el entorno de trabajo MATLAB. Se explicará la creación del modelo del robot, la planificación de trayectorias y la comunicación con dicho robot. This project uses the ROS (Robot Operating System) environment for developing the control of the IRB 120 robotic arm and its implementation in the MATLAB working environment. It will explain the creation of the...

  9. Robotically facilitated virtual rehabilitation of arm transport integrated with finger movement in persons with hemiparesis

    Directory of Open Access Journals (Sweden)

    Davidow Amy

    2011-05-01

    Full Text Available Abstract Background Recovery of upper extremity function is particularly recalcitrant to successful rehabilitation. Robotic-assisted arm training devices integrated with virtual targets or complex virtual reality gaming simulations are being developed to deal with this problem. Neural control mechanisms indicate that reaching and hand-object manipulation are interdependent, suggesting that training on tasks requiring coordinated effort of both the upper arm and hand may be a more effective method for improving recovery of real world function. However, most robotic therapies have focused on training the proximal, rather than distal effectors of the upper extremity. This paper describes the effects of robotically-assisted, integrated upper extremity training. Methods Twelve subjects post-stroke were trained for eight days on four upper extremity gaming simulations using adaptive robots during 2-3 hour sessions. Results The subjects demonstrated improved proximal stability, smoothness and efficiency of the movement path. This was in concert with improvement in the distal kinematic measures of finger individuation and improved speed. Importantly, these changes were accompanied by a robust 16-second decrease in overall time in the Wolf Motor Function Test and a 24-second decrease in the Jebsen Test of Hand Function. Conclusions Complex gaming simulations interfaced with adaptive robots requiring integrated control of shoulder, elbow, forearm, wrist and finger movements appear to have a substantial effect on improving hemiparetic hand function. We believe that the magnitude of the changes and the stability of the patient's function prior to training, along with maintenance of several aspects of the gains demonstrated at retention make a compelling argument for this approach to training.

  10. Combination of Robot Simulation with Real-time Monitoring and Control

    Directory of Open Access Journals (Sweden)

    Jianyu YANG

    2014-08-01

    Full Text Available The paper mainly focuses in combining virtual reality based operation simulation with remote real-time monitoring and control method for an experimental robot. A system composition framework was designed and relative arm-wheel experimental robot platform was also built. Virtual robots and two virtual environments were developed. To locate the virtual robot within numerical environments, relative mathematical methods is also discussed, including analytic locating methods for linear motion and self-rotation, as well as linear transformation method with homogeneous matrices for turning motion, in order to decrease division calculations. Several experiments were carried out, trajectory errors were found because of relative slides between the wheel and the floor, during the locating experiments. Writing-monitoring experiments were also performed by programming the robotic arm to write a Chinese character, and the virtual robot in monitoring terminal perfectly followed all the movements. All the experiment results confirmed that virtual environment can not only be used as a good supplement to the traditional video monitoring method, but also offer better control experience during the operation.

  11. Interface evaluation for soft robotic manipulators

    Science.gov (United States)

    Moore, Kristin S.; Rodes, William M.; Csencsits, Matthew A.; Kwoka, Martha J.; Gomer, Joshua A.; Pagano, Christopher C.

    2006-05-01

    The results of two usability experiments evaluating an interface for the operation of OctArm, a biologically inspired robotic arm modeled after an octopus tentacle, are reported. Due to the many degrees-of-freedom (DOF) for the operator to control, such 'continuum' robotic limbs provide unique challenges for human operators because they do not map intuitively. Two modes have been developed to control the arm and reduce the DOF under the explicit direction of the operator. In coupled velocity (CV) mode, a joystick controls changes in arm curvature. In end-effector (EE) mode, a joystick controls the arm by moving the position of an endpoint along a straight line. In Experiment 1, participants used the two modes to grasp objects placed at different locations in a virtual reality modeling language (VRML). Objective measures of performance and subjective preferences were recorded. Results revealed lower grasp times and a subjective preference for the CV mode. Recommendations for improving the interface included providing additional feedback and implementation of an error recovery function. In Experiment 2, only the CV mode was tested with improved training of participants and several changes to the interface. The error recovery function was implemented, allowing participants to reverse through previously attained positions. The mean time to complete the trials in the second usability test was reduced by more than 4 minutes compared with the first usability test, confirming the interface changes improved performance. The results of these tests will be incorporated into future versions of the arm and improve future usability tests.

  12. Phoenix Robotic Arm's Workspace After 90 Sols

    Science.gov (United States)

    2008-01-01

    During the first 90 Martian days, or sols, after its May 25, 2008, landing on an arctic plain of Mars, NASA's Phoenix Mars Lander dug several trenches in the workspace reachable with the lander's robotic arm. The lander's Surface Stereo Imager camera recorded this view of the workspace on Sol 90, early afternoon local Mars time (overnight Aug. 25 to Aug. 26, 2008). The shadow of the the camera itself, atop its mast, is just left of the center of the image and roughly a third of a meter (one foot) wide. The workspace is on the north side of the lander. The trench just to the right of center is called 'Neverland.' The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  13. Getting started with robotics in general surgery with cholecystectomy: the Canadian experience

    Science.gov (United States)

    Jayaraman, Shiva; Davies, Ward; Schlachta, Christopher M.

    2009-01-01

    Background The value of robotics in general surgery may be for advanced minimally invasive procedures. Unlike other specialties, formal fellowship training opportunities for robotic general surgery are few. As a result, most surgeons currently develop robotic skills in practice. Our goal was to determine whether robotic cholecystectomy is a safe and effective bridge to advanced robotics in general surgery. Methods Before performing advanced robotic procedures, 2 surgeons completed the Intuitive Surgical da Vinci training course and agreed to work together on all procedures. Clinical surgery began with da Vinci cholecystectomy with a plan to begin advanced procedures after at least 10 cholecystectomies. We performed a retrospective review of our pilot series of robotic cholecystectomies and compared them with contemporaneous laparoscopic controls. The primary outcome was safety, and the secondary outcome was learning curve. Results There were 16 procedures in the robotics arm and 20 in the laparoscopic arm. Two complications (da Vinci port-site hernia, transient elevation of liver enzymes) occurred in the robotic arm, whereas only 1 laparoscopic patient (slow to awaken from anesthetic) experienced a complication. None was significant. The mean time required to perform robotic cholecystectomy was significantly longer than laparoscopic surgery (91 v. 41 min, p robotic procedures (14 v. 11 min, p = 0.015). We observed a trend showing longer mean anesthesia time for robotic procedures (23 v. 15 min). Regarding learning curve, the mean operative time needed for the first 3 robotic procedures was longer than for the last 3 (101 v. 80 min); however, this difference was not significant. Since this experience, the team has confidently gone on to perform robotic biliary, pancreatic, gastresophageal, intestinal and colorectal operations. Conclusion Robotic cholecystectomy can be performed reliably; however, owing to the significant increase in operating room resources, it

  14. Getting started with robotics in general surgery with cholecystectomy: the Canadian experience.

    Science.gov (United States)

    Jayaraman, Shiva; Davies, Ward; Schlachta, Christopher M

    2009-10-01

    The value of robotics in general surgery may be for advanced minimally invasive procedures. Unlike other specialties, formal fellowship training opportunities for robotic general surgery are few. As a result, most surgeons currently develop robotic skills in practice. Our goal was to determine whether robotic cholecystectomy is a safe and effective bridge to advanced robotics in general surgery. Before performing advanced robotic procedures, 2 surgeons completed the Intuitive Surgical da Vinci training course and agreed to work together on all procedures. Clinical surgery began with da Vinci cholecystectomy with a plan to begin advanced procedures after at least 10 cholecystectomies. We performed a retrospective review of our pilot series of robotic cholecystectomies and compared them with contemporaneous laparoscopic controls. The primary outcome was safety, and the secondary outcome was learning curve. There were 16 procedures in the robotics arm and 20 in the laparoscopic arm. Two complications (da Vinci port-site hernia, transient elevation of liver enzymes) occurred in the robotic arm, whereas only 1 laparoscopic patient (slow to awaken from anesthetic) experienced a complication. None was significant. The mean time required to perform robotic cholecystectomy was significantly longer than laparoscopic surgery (91 v. 41 min, p robotic procedures (14 v. 11 min, p = 0.015). We observed a trend showing longer mean anesthesia time for robotic procedures (23 v. 15 min). Regarding learning curve, the mean operative time needed for the first 3 robotic procedures was longer than for the last 3 (101 v. 80 min); however, this difference was not significant. Since this experience, the team has confidently gone on to perform robotic biliary, pancreatic, gastresophageal, intestinal and colorectal operations. Robotic cholecystectomy can be performed reliably; however, owing to the significant increase in operating room resources, it cannot be justified for routine use. Our

  15. Trajectory Planning with Pose Feedback for a Dual-Arm Space Robot

    Directory of Open Access Journals (Sweden)

    Yicheng Liu

    2016-01-01

    Full Text Available In order to obtain high precision path tracking for a dual-arm space robot, a trajectory planning method with pose feedback is proposed to be introduced into the design process in this paper. Firstly, pose error kinematic models are derived from the related kinematics and desired pose command for the end-effector and the base, respectively. On this basis, trajectory planning with pose feedback is proposed from a control perspective. Theoretical analyses show that the proposed trajectory planning algorithm can guarantee that pose error converges to zero exponentially for both the end-effector and the base when the robot is out of singular configuration. Compared with the existing algorithms, the proposed algorithm can lead to higher precision path tracking for the end-effector. Furthermore, the algorithm renders the system good anti-interference property for the base. Simulation results demonstrate the effectiveness of the proposed trajectory planning algorithm.

  16. Estimation of Human Arm Joints Using Two Wireless Sensors in Robotic Rehabilitation Tasks

    Directory of Open Access Journals (Sweden)

    Arturo Bertomeu-Motos

    2015-12-01

    Full Text Available This paper presents a novel kinematic reconstruction of the human arm chain with five degrees of freedom and the estimation of the shoulder location during rehabilitation therapy assisted by end-effector robotic devices. This algorithm is based on the pseudoinverse of the Jacobian through the acceleration of the upper arm, measured using an accelerometer, and the orientation of the shoulder, estimated with a magnetic angular rate and gravity (MARG device. The results show a high accuracy in terms of arm joints and shoulder movement with respect to the real arm measured through an optoelectronic system. Furthermore, the range of motion (ROM of 50 healthy subjects is studied from two different trials, one trying to avoid shoulder movements and the second one forcing them. Moreover, the shoulder movement in the second trial is also estimated accurately. Besides the fact that the posture of the patient can be corrected during the exercise, the therapist could use the presented algorithm as an objective assessment tool. In conclusion, the joints’ estimation enables a better adjustment of the therapy, taking into account the needs of the patient, and consequently, the arm motion improves faster.

  17. History of Robotic and Remotely Operated Telescopes

    Science.gov (United States)

    Genet, Russell M.

    2011-03-01

    While automated instrument sequencers were employed on solar eclipse expeditions in the late 1800s, it wasn't until the 1960s that Art Code and associates at Wisconsin used a PDP minicomputer to automate an 8-inch photometric telescope. Although this pioneering project experienced frequent equipment failures and was shut down after a couple of years, it paved the way for the first space telescopes. Reliable microcomputers initiated the modern era of robotic telescopes. Louis Boyd and I applied single board microcomputers with 64K of RAM and floppy disk drives to telescope automation at the Fairborn Observatory, achieving reliable, fully robotic operation in 1983 that has continued uninterrupted for 28 years. In 1985 the Smithsonian Institution provided us with a suburb operating location on Mt. Hopkins in southern Arizona, while the National Science Foundation funded additional telescopes. Remote access to our multiple robotic telescopes at the Fairborn Observatory began in the late 1980s. The Fairborn Observatory, with its 14 fully robotic telescopes and staff of two (one full and one part time) illustrates the potential for low operating and maintenance costs. As the information capacity of the Internet has expanded, observational modes beyond simple differential photometry opened up, bringing us to the current era of real-time remote access to remote observatories and global observatory networks. Although initially confined to smaller telescopes, robotic operation and remote access are spreading to larger telescopes as telescopes from afar becomes the normal mode of operation.

  18. Towards Using a Generic Robot as Training Partner

    DEFF Research Database (Denmark)

    Sørensen, Anders Stengaard; Savarimuthu, Thiusius Rajeeth; Nielsen, Jacob

    2014-01-01

    In this paper, we demonstrate how a generic industrial robot can be used as a training partner, for upper limb training. The motion path and human/robot interaction of a non-generic upper-arm training robot is transferred to a generic industrial robot arm, and we demonstrate that the robot arm can...... implement the same type of interaction, but can expand the training regime to include both upper arm and shoulder training. We compare the generic robot to two affordable but custom-built training robots, and outline interesting directions for future work based on these training robots....

  19. A remotely operated robot for decontamination tasks

    International Nuclear Information System (INIS)

    Dudar, A.M.; Vandewalle, R.C.

    1994-01-01

    Engineers in the Robotics Development Group at the Westinghouse Savannah River Company (WSRC) have developed a robot which will be used to decontaminate a pipe gallery of a tank farm used for nuclear waste storage. Personnel access is required into this pipe gallery to inspect existing pipes and perform repairs to secondary containment walls around the tank farm. Presently, the pipe gallery is littered with debris of various sizes and its surface is contaminated with activity levels up to 2.5E6 DPM (disintegrations per minute) alpha and exposure levels as high as 20 Rad/hr. Cleaning up this pipe gallery win be the mission of an all-hydraulic robotic vehicle developed in-house at WSRC caged the ''Remote Decon'' robot. The Remote Decon is a tracked vehicle which utilizes skid steering and features a six-degree-of-freedom (DOF) manipulator arm, a five-DOF front end loader type bucket with a rotating brush for scrubbing and decontaminating surfaces, and a three-DOF pan/tilt mechanism with cameras and lights. The Remote Decon system is connected to a control console via a 200 foot tethered cable. The control console was designed with ergonomics and simplicity as the main design factors and features three joysticks, video monitors, LED panels, and audible alarms

  20. An Articulated Inspection Arm for fusion purposes

    Energy Technology Data Exchange (ETDEWEB)

    Villedieu, E., E-mail: eric.villedieu@cea.fr [CEA-IRFM, 13108 Saint Paul lez Durance (France); Bruno, V.; Pastor, P.; Gargiulo, L. [CEA-IRFM, 13108 Saint Paul lez Durance (France); Song, Y.T.; Cheng, Y.; Feng, H. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei (China); Liu, C. [CEA-IRFM, 13108 Saint Paul lez Durance (France); Institute of Plasma Physics, Chinese Academy of Sciences, Hefei (China); Shi, S.S. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei (China)

    2016-11-01

    Highlights: • Requirements for in vacuum tokamak inspection are presented. • Development of a prototype of the Articulated Inspection Arm is described. • The upgrade of the prototype to convert it into a fully operational device is detailed. • Future applications of inspection robots in the new fusion reactors is discussed. - Abstract: Fusion Tokamaks are complex machines which require special conditions for their operation, in particular, high vacuum inside the vessel and high temperature of the vessel walls. During plasma phases, the first wall components are highly stressed and a control is necessary in case of doubt about their condition. To be able to make safely such an inspection in a short period of time is a great advantage. The Articulated Inspection Arm (AIA) developed by the CEA provides the capability for fast inspections of the first wall overall surface keeping the vacuum and temperature conditions of the vessel. The robot prototype was validated in Tore Supra in 2008. In the frame of a joint laboratory, CEA/IRFM and ASIPP have decided to upgrade the existing AIA prototype to use it routinely in the EAST and WEST tokamaks. The robot has followed an important upgrade program in 2013 and 2014. The document presents the various upgrades made on the mechanics, the sensors, the electronics, the control station and the integration adaptation for the operation on EAST. From the AIA experience, thoughts for future inspection robots are given.

  1. An Articulated Inspection Arm for fusion purposes

    International Nuclear Information System (INIS)

    Villedieu, E.; Bruno, V.; Pastor, P.; Gargiulo, L.; Song, Y.T.; Cheng, Y.; Feng, H.; Liu, C.; Shi, S.S.

    2016-01-01

    Highlights: • Requirements for in vacuum tokamak inspection are presented. • Development of a prototype of the Articulated Inspection Arm is described. • The upgrade of the prototype to convert it into a fully operational device is detailed. • Future applications of inspection robots in the new fusion reactors is discussed. - Abstract: Fusion Tokamaks are complex machines which require special conditions for their operation, in particular, high vacuum inside the vessel and high temperature of the vessel walls. During plasma phases, the first wall components are highly stressed and a control is necessary in case of doubt about their condition. To be able to make safely such an inspection in a short period of time is a great advantage. The Articulated Inspection Arm (AIA) developed by the CEA provides the capability for fast inspections of the first wall overall surface keeping the vacuum and temperature conditions of the vessel. The robot prototype was validated in Tore Supra in 2008. In the frame of a joint laboratory, CEA/IRFM and ASIPP have decided to upgrade the existing AIA prototype to use it routinely in the EAST and WEST tokamaks. The robot has followed an important upgrade program in 2013 and 2014. The document presents the various upgrades made on the mechanics, the sensors, the electronics, the control station and the integration adaptation for the operation on EAST. From the AIA experience, thoughts for future inspection robots are given.

  2. A highly articulated robotic surgical system for minimally invasive surgery.

    Science.gov (United States)

    Ota, Takeyoshi; Degani, Amir; Schwartzman, David; Zubiate, Brett; McGarvey, Jeremy; Choset, Howie; Zenati, Marco A

    2009-04-01

    We developed a novel, highly articulated robotic surgical system (CardioARM) to enable minimally invasive intrapericardial therapeutic delivery through a subxiphoid approach. We performed preliminary proof of concept studies in a porcine preparation by performing epicardial ablation. CardioARM is a robotic surgical system having an articulated design to provide unlimited but controllable flexibility. The CardioARM consists of serially connected, rigid cyclindrical links housing flexible working ports through which catheter-based tools for therapy and imaging can be advanced. The CardioARM is controlled by a computer-driven, user interface, which is operated outside the operative field. In six experimental subjects, the CardioARM was introduced percutaneously through a subxiphoid access. A commercial 5-French radiofrequency ablation catheter was introduced through the working port, which was then used to guide deployment. In all subjects, regional ("linear") left atrial ablation was successfully achieved without complications. Based on these preliminary studies, we believe that the CardioARM promises to enable deployment of a number of epicardium-based therapies. Improvements in imaging techniques will likely facilitate increasingly complex procedures.

  3. The ARAMIS project: a concept robot and technical design.

    Science.gov (United States)

    Colizzi, Lucio; Lidonnici, Antonio; Pignolo, Loris

    2009-11-01

    To describe the ARAMIS (Automatic Recovery Arm Motility Integrated System) project, a concept robot applicable in the neuro-rehabilitation of the paretic upper limb after stroke. Methods, results and conclusion: The rationale and engineering of a state-of-the-art, hardware/software integrated robot system, its mechanics, ergonomics, electric/electronics features providing control, safety and suitability of use are described. An ARAMIS prototype has been built and is now available for clinical tests. It allows the therapist to design neuro-rehabilitative (synchronous or asynchronous) training protocols in which sample exercises are generated by a single exoskeleton (operated by the patient's unaffected arm or by the therapist's arm) and mirrored in real-time or offline by the exoskeleton supporting the paretic arm.

  4. Evaluation of a completely robotized neurosurgical operating microscope.

    Science.gov (United States)

    Kantelhardt, Sven R; Finke, Markus; Schweikard, Achim; Giese, Alf

    2013-01-01

    Operating microscopes are essential for most neurosurgical procedures. Modern robot-assisted controls offer new possibilities, combining the advantages of conventional and automated systems. We evaluated the prototype of a completely robotized operating microscope with an integrated optical coherence tomography module. A standard operating microscope was fitted with motors and control instruments, with the manual control mode and balance preserved. In the robot mode, the microscope was steered by a remote control that could be fixed to a surgical instrument. External encoders and accelerometers tracked microscope movements. The microscope was additionally fitted with an optical coherence tomography-scanning module. The robotized microscope was tested on model systems. It could be freely positioned, without forcing the surgeon to take the hands from the instruments or avert the eyes from the oculars. Positioning error was about 1 mm, and vibration faded in 1 second. Tracking of microscope movements, combined with an autofocus function, allowed determination of the focus position within the 3-dimensional space. This constituted a second loop of navigation independent from conventional infrared reflector-based techniques. In the robot mode, automated optical coherence tomography scanning of large surface areas was feasible. The prototype of a robotized optical coherence tomography-integrated operating microscope combines the advantages of a conventional manually controlled operating microscope with a remote-controlled positioning aid and a self-navigating microscope system that performs automated positioning tasks such as surface scans. This demonstrates that, in the future, operating microscopes may be used to acquire intraoperative spatial data, volume changes, and structural data of brain or brain tumor tissue.

  5. A Proposal for Automatic Fruit Harvesting by Combining a Low Cost Stereovision Camera and a Robotic Arm

    Science.gov (United States)

    Font, Davinia; Pallejà, Tomàs; Tresanchez, Marcel; Runcan, David; Moreno, Javier; Martínez, Dani; Teixidó, Mercè; Palacín, Jordi

    2014-01-01

    This paper proposes the development of an automatic fruit harvesting system by combining a low cost stereovision camera and a robotic arm placed in the gripper tool. The stereovision camera is used to estimate the size, distance and position of the fruits whereas the robotic arm is used to mechanically pickup the fruits. The low cost stereovision system has been tested in laboratory conditions with a reference small object, an apple and a pear at 10 different intermediate distances from the camera. The average distance error was from 4% to 5%, and the average diameter error was up to 30% in the case of a small object and in a range from 2% to 6% in the case of a pear and an apple. The stereovision system has been attached to the gripper tool in order to obtain relative distance, orientation and size of the fruit. The harvesting stage requires the initial fruit location, the computation of the inverse kinematics of the robotic arm in order to place the gripper tool in front of the fruit, and a final pickup approach by iteratively adjusting the vertical and horizontal position of the gripper tool in a closed visual loop. The complete system has been tested in controlled laboratory conditions with uniform illumination applied to the fruits. As a future work, this system will be tested and improved in conventional outdoor farming conditions. PMID:24984059

  6. A Proposal for Automatic Fruit Harvesting by Combining a Low Cost Stereovision Camera and a Robotic Arm

    Directory of Open Access Journals (Sweden)

    Davinia Font

    2014-06-01

    Full Text Available This paper proposes the development of an automatic fruit harvesting system by combining a low cost stereovision camera and a robotic arm placed in the gripper tool. The stereovision camera is used to estimate the size, distance and position of the fruits whereas the robotic arm is used to mechanically pickup the fruits. The low cost stereovision system has been tested in laboratory conditions with a reference small object, an apple and a pear at 10 different intermediate distances from the camera. The average distance error was from 4% to 5%, and the average diameter error was up to 30% in the case of a small object and in a range from 2% to 6% in the case of a pear and an apple. The stereovision system has been attached to the gripper tool in order to obtain relative distance, orientation and size of the fruit. The harvesting stage requires the initial fruit location, the computation of the inverse kinematics of the robotic arm in order to place the gripper tool in front of the fruit, and a final pickup approach by iteratively adjusting the vertical and horizontal position of the gripper tool in a closed visual loop. The complete system has been tested in controlled laboratory conditions with uniform illumination applied to the fruits. As a future work, this system will be tested and improved in conventional outdoor farming conditions.

  7. Early Stroke Rehabilitation of the Upper Limb Assisted with an Electromyography-Driven Neuromuscular Electrical Stimulation-Robotic Arm

    Directory of Open Access Journals (Sweden)

    Qiuyang Qian

    2017-09-01

    Full Text Available BackgroundEffective poststroke motor rehabilitation depends on repeated limb practice with voluntary efforts. An electromyography (EMG-driven neuromuscular electrical stimulation (NMES-robot arm was designed for the multi-joint physical training on the elbow, the wrist, and the fingers.ObjectivesTo investigate the training effects of the device-assisted approach on subacute stroke patients and to compare the effects with those achieved by the traditional physical treatments.MethodThis study was a pilot randomized controlled trial with a 3-month follow-up. Subacute stroke participants were randomly assigned into two groups, and then received 20-session upper limb training with the EMG-driven NMES-robotic arm (NMES-robot group, n = 14 or the time-matched traditional therapy (the control, n = 10. For the evaluation of the training effects, clinical assessments including Fugl-Meyer Assessment (FMA, Modified Ashworth Score (MAS, Action Research Arm Test (ARAT, and Function Independence Measurement (FIM were conducted before, after the rehabilitation training, and 3 months later. Session-by-session EMG parameters in the NMES-robot group, including normalized co-contraction Indexes (CI and EMG activation level of target muscles, were used to monitor the progress in muscular coordination patterns.ResultsSignificant improvements were obtained in FMA (full score and shoulder/elbow, ARAT, and FIM [P < 0.001, effect sizes (EFs > 0.279] for both groups. Significant improvement in FMA wrist/hand was only observed in the NMES-robot group (P < 0.001, EFs = 0.435 after the treatments. Significant reduction in MAS wrist was observed in the NMES-robot group after the training (P < 0.05, EFs = 0.145 and the effects were maintained for 3 months. MAS scores in the control group were elevated following training (P < 0.05, EFs > 0.24, and remained at an elevated level when assessed 3 months later. The EMG parameters

  8. Computer vision system R&D for EAST Articulated Maintenance Arm robot

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Linglong, E-mail: linglonglin@ipp.ac.cn; Song, Yuntao, E-mail: songyt@ipp.ac.cn; Yang, Yang, E-mail: yangy@ipp.ac.cn; Feng, Hansheng, E-mail: hsfeng@ipp.ac.cn; Cheng, Yong, E-mail: chengyong@ipp.ac.cn; Pan, Hongtao, E-mail: panht@ipp.ac.cn

    2015-11-15

    Highlights: • We discussed the image preprocessing, object detection and pose estimation algorithms under poor light condition of inner vessel of EAST tokamak. • The main pipeline, including contours detection, contours filter, MER extracted, object location and pose estimation, was carried out in detail. • The technical issues encountered during the research were discussed. - Abstract: Experimental Advanced Superconducting Tokamak (EAST) is the first full superconducting tokamak device which was constructed at Institute of Plasma Physics Chinese Academy of Sciences (ASIPP). The EAST Articulated Maintenance Arm (EAMA) robot provides the means of the in-vessel maintenance such as inspection and picking up the fragments of first wall. This paper presents a method to identify and locate the fragments semi-automatically by using the computer vision. The use of computer vision in identification and location faces some difficult challenges such as shadows, poor contrast, low illumination level, less texture and so on. The method developed in this paper enables credible identification of objects with shadows through invariant image and edge detection. The proposed algorithms are validated through our ASIPP robotics and computer vision platform (ARVP). The results show that the method can provide a 3D pose with reference to robot base so that objects with different shapes and size can be picked up successfully.

  9. Robotics and tele-operation technology for applications in nuclear fields

    International Nuclear Information System (INIS)

    Kosuge, Kazuhiro; Hirata, Yasuhisa; Takeo, Koji

    2002-01-01

    In this article, we introduce available robotics and tele-operation technology for applications in Nuclear Fields. First, robotics technology for manipulation of a large object is introduced which has been experimentally applied to ITER Maintenance Robot. Then, transportation technology of a large object by multiple mobile robots is reviewed. At last, recent tele-operation technologies and a prototype tele-operation system, referred to as VISIT (Visual Interface System for Interactive Task-execution), is introduced. Several experimental results are also introduced. (author)

  10. Innovation in Robotic Surgery: The Indian Scenario

    Directory of Open Access Journals (Sweden)

    Suresh V Deshpande

    2015-01-01

    Full Text Available Robotics is the science. In scientific words a "Robot" is an electromechanical arm device with a computer interface, a combination of electrical, mechanical, and computer engineering. It is a mechanical arm that performs tasks in Industries, space exploration, and science. One such idea was to make an automated arm - A robot - In laparoscopy to control the telescope-camera unit electromechanically and then with a computer interface using voice control. It took us 5 long years from 2004 to bring it to the level of obtaining a patent. That was the birth of the Swarup Robotic Arm (SWARM which is the first and the only Indian contribution in the field of robotics in laparoscopy as a total voice controlled camera holding robotic arm developed without any support by industry or research institutes.

  11. Innovation in robotic surgery: the Indian scenario.

    Science.gov (United States)

    Deshpande, Suresh V

    2015-01-01

    Robotics is the science. In scientific words a "Robot" is an electromechanical arm device with a computer interface, a combination of electrical, mechanical, and computer engineering. It is a mechanical arm that performs tasks in Industries, space exploration, and science. One such idea was to make an automated arm - A robot - In laparoscopy to control the telescope-camera unit electromechanically and then with a computer interface using voice control. It took us 5 long years from 2004 to bring it to the level of obtaining a patent. That was the birth of the Swarup Robotic Arm (SWARM) which is the first and the only Indian contribution in the field of robotics in laparoscopy as a total voice controlled camera holding robotic arm developed without any support by industry or research institutes.

  12. Robotics combined with electrical stimulation : hybrid support of arm and hand for functional training after stroke

    NARCIS (Netherlands)

    Westerveld, Ard

    2014-01-01

    Reach, grasp and release is part of many functional movements. Graying of society leads to more stroke victims and fewer health care professionals. Technology might be a solution to support certain rehabilitation therapies in future health care. Robotic systems have been developed for support of arm

  13. Robotics combined with electrical stimulation: hybrid support of arm and hand for functional training after stroke

    NARCIS (Netherlands)

    Westerveld, Ard

    2014-01-01

    Reach, grasp and release is part of many functional movements. Graying of society leads to more stroke victims and fewer health care professionals. Technology might be a solution to support certain rehabilitation therapies in future health care. Robotic systems have been developed for support of arm

  14. Development of an integrated closed loop control system with virtual reality monitoring for Prototype Robotic Articulated System (PRAS)

    International Nuclear Information System (INIS)

    Rastogi, Naveen; Dutta, Pramit; Gotewal, K.K.

    2015-01-01

    The Prototype Robotic Articulated System (PRAS) is a servo driven 4 degrees of freedom robotic arm capable of handling of upto 5 kg payload. A virtual reality based monitoring application has been developed in blender and was intergrated with the control system to read the joint values of the robotic arm at 10Hz and update the CAD model to visualize the robotic operations remotely. This paper presents the design details and implementation results of the integrated control system for PRAS

  15. Integration of Haptics in Agricultural Robotics

    Science.gov (United States)

    Kannan Megalingam, Rajesh; Sreekanth, M. M.; Sivanantham, Vinu; Sai Kumar, K.; Ghanta, Sriharsha; Surya Teja, P.; Reddy, Rajesh G.

    2017-08-01

    Robots can differentiate with open loop system and closed loop system robots. We face many problems when we do not have a feedback from robots. In this research paper, we are discussing all possibilities to achieve complete closed loop system for Multiple-DOF Robotic Arm, which is used in a coconut tree climbing and cutting robot by introducing a Haptic device. We are working on various sensors like tactile, vibration, force and proximity sensors for getting feedback. For monitoring the robotic arm achieved by graphical user interference software which simulates the working of the robotic arm, send the feedback of all the real time analog values which are produced by various sensors and provide real-time graphs for estimate the efficiency of the Robot.

  16. A Low-Cost Immersive Virtual Reality System for Teaching Robotic Manipulators Programming

    Directory of Open Access Journals (Sweden)

    Vicente Román-Ibáñez

    2018-04-01

    Full Text Available Laboratory tasks are a powerful pedagogical strategy for developing competences in science and engineering degrees, making students understand in a practical way the theoretical topics explained in the classroom. However, performing experiments in real conditions is usually expensive in terms of time, money and energy, as it requires expensive infrastructures that are generally difficult to maintain in good conditions. To overcome this problem, virtual reality has proven to be a powerful tool to achieve sustainability, making it easy to update laboratories without the need to acquire new equipment. Moreover, the ability to introduce practical knowledge into classrooms without leaving them, makes virtual laboratories capable of simulating typical operating environments as well as extreme situations in the operation of different devices. A typical subject in which students can benefit from the use of virtual laboratories is robotics. In this work we will develop an immersive virtual reality (VR pedagogical simulator of industrial robotic arms for engineering students. With the proposed system, students will know the effects of their own designed trajectories on several different robotic arms and cell environments without having to buy all of them and being safe of damaging the cell components. The simulation will be checking for collisions of the elements in the scene and alert the student when they happen. This can be achieved with a robotic simulator, but the integration with immersive VR is intended to help students better understand robotics. Moreover, even having a real robotic arm available for students, with this proposed VR method, all the students have the opportunity to manage and learn his own version of the robotic cell, without waiting times generated by having less robotic arms than students in classroom.

  17. Emulating a robotic manipulator arm with an hybrid motion-control system

    International Nuclear Information System (INIS)

    Aragón-González, G; León-Galicia, A; Noriega-Hernández, M; Salazar-Hueta, A

    2015-01-01

    A motion control system with four and 1/2 degrees of freedom, designed to move small objects within a 0.25 m3 space, parallel to a horizontal table, with high speed and performance similar to a robotic manipulator arm was built. The machine employs several actuators and control devices. Its main characteristic is to incorporate a servomotor, steeper motors, electromechanical and fluid power actuators and diverse control resources. A group of actuators arranged on a spherical coordinates system is attached to the servomotor platform. A linear pneumatic actuator with an angular grip provides the radial extension and load clamping capacity. Seven inductive proximity sensors and one encoder provide feedback, for operating the actuators under closed loop conditions. Communication between the sensors and control devices is organized by a PLC. A touch screen allows governing the system remotely, easily and interactively, without knowing the specific programming language of each control component. The graphic environment on the touch screen guides the user to design and store control programs, establishing coordinated automatic routines for moving objects in space, simulation and implementation of industrial positioning or machining processes

  18. Using Functional Electrical Stimulation Mediated by Iterative Learning Control and Robotics to Improve Arm Movement for People With Multiple Sclerosis.

    Science.gov (United States)

    Sampson, Patrica; Freeman, Chris; Coote, Susan; Demain, Sara; Feys, Peter; Meadmore, Katie; Hughes, Ann-Marie

    2016-02-01

    Few interventions address multiple sclerosis (MS) arm dysfunction but robotics and functional electrical stimulation (FES) appear promising. This paper investigates the feasibility of combining FES with passive robotic support during virtual reality (VR) training tasks to improve upper limb function in people with multiple sclerosis (pwMS). The system assists patients in following a specified trajectory path, employing an advanced model-based paradigm termed iterative learning control (ILC) to adjust the FES to improve accuracy and maximise voluntary effort. Reaching tasks were repeated six times with ILC learning the optimum control action from previous attempts. A convenience sample of five pwMS was recruited from local MS societies, and the intervention comprised 18 one-hour training sessions over 10 weeks. The accuracy of tracking performance without FES and the amount of FES delivered during training were analyzed using regression analysis. Clinical functioning of the arm was documented before and after treatment with standard tests. Statistically significant results following training included: improved accuracy of tracking performance both when assisted and unassisted by FES; reduction in maximum amount of FES needed to assist tracking; and less impairment in the proximal arm that was trained. The system was well tolerated by all participants with no increase in muscle fatigue reported. This study confirms the feasibility of FES combined with passive robot assistance as a potentially effective intervention to improve arm movement and control in pwMS and provides the basis for a follow-up study.

  19. A new CT-aided robotic stereotaxis system

    International Nuclear Information System (INIS)

    Shao, H.M.; Chen, J.Y.; Truong, T.K.; Reed, I.S.

    1985-01-01

    In this paper, it is shown that a robot arm may be programmed to replace the stereotaxic frame for trajectory guidance. Since the robot is driven by a computer, it offers substantial flexibility, speed and accuracy advantages over the frame. It allows a surgeon to conveniently manipulate the probe trajectory in a variety of possible directions. As a consequence, even more sophisticated stereotaxic procedures are now possible. An experimental robotic stereotaxic system is now in operation. It is described in detail in this paper

  20. Sistem Kontrol Robot Arm 5 DOF Berbasis Pengenalan Pola Suara Menggunakan Mel-Frequency Cepstrum Coefficients (MFCC dan Adaptive Neuro-Fuzzy Inference System (ANFIS

    Directory of Open Access Journals (Sweden)

    WS Mada Sanjaya

    2016-12-01

    Full Text Available Telah dilakukan penelitian yang menggambarkan implementasi pengenalan pola suara untuk mengontrol gerak robot arm 5 DoF dalam mengambil dan menyimpan benda. Dalam penelitian ini metode yang digunakan adalah Mel-Frequency Cepstrum Coefficients (MFCC dan Adaptive Neuro-Fuzzy Inferense System (ANFIS. Metode MFCC digunakan untuk ekstraksi ciri sinyal suara, sedangkan ANFIS digunakan sebagai metode pembelajaran untuk pengenalan pola suara. Pada proses pembelajaran ANFIS data latih yang digunakan sebanyak 6 ciri. Data suara terlatih dan data suara tak terlatih digunakan untuk pengujian sistem pengenalan pola suara. Hasil pengujian menunjukkan tingkat keberhasilan, untuk data suara terlatih sebesar 87,77% dan data tak terlatih sebesar 78,53%. Sistem pengenalan pola suara ini telah diaplikasikan dengan baik untuk mengerakan robot arm 5 DoF berbasis mikrokontroler Arduino. Have been implemented of sound pattern recognition to control 5 DoF of Arm Robot to pick and place an object. In this research used Mel-Frequency Cepstrum Coefficients (MFCC and Adaptive Neuro-Fuzzy Interferense System (ANFIS methods. MFCC method used for features extraction of sound signal, meanwhile ANFIS used to learn sound pattern recognition. On ANFIS method data learning use 6 features. Trained and not trained data used to examine the system of sound pattern identification. The result show the succesfull level, for trained data 87.77% and for not trained data 78.53%. Sound pattern identification system was appliedto controlled 5 DoF arm robot based Arduino microcontroller.

  1. Virtual Reality Robotic Operation Simulations Using MEMICA Haptic System

    Science.gov (United States)

    Bar-Cohen, Y.; Mavroidis, C.; Bouzit, M.; Dolgin, B.; Harm, D. L.; Kopchok, G. E.; White, R.

    2000-01-01

    There is an increasing realization that some tasks can be performed significantly better by humans than robots but, due to associated hazards, distance, etc., only a robot can be employed. Telemedicine is one area where remotely controlled robots can have a major impact by providing urgent care at remote sites. In recent years, remotely controlled robotics has been greatly advanced. The robotic astronaut, "Robonaut," at NASA Johnson Space Center is one such example. Unfortunately, due to the unavailability of force and tactile feedback capability the operator must determine the required action using only visual feedback from the remote site, which limits the tasks that Robonaut can perform. There is a great need for dexterous, fast, accurate teleoperated robots with the operator?s ability to "feel" the environment at the robot's field. Recently, we conceived a haptic mechanism called MEMICA (Remote MEchanical MIrroring using Controlled stiffness and Actuators) that can enable the design of high dexterity, rapid response, and large workspace system. Our team is developing novel MEMICA gloves and virtual reality models to allow the simulation of telesurgery and other applications. The MEMICA gloves are designed to have a high dexterity, rapid response, and large workspace and intuitively mirror the conditions at a virtual site where a robot is simulating the presence of the human operator. The key components of MEMICA are miniature electrically controlled stiffness (ECS) elements and Electrically Controlled Force and Stiffness (ECFS) actuators that are based on the sue of Electro-Rheological Fluids (ERF). In this paper the design of the MEMICA system and initial experimental results are presented.

  2. An Interactive Human Interface Arm Robot with the Development of Food Aid

    Directory of Open Access Journals (Sweden)

    NASHWAN D. Zaki

    2012-03-01

    Full Text Available A robotic system for the disabled who needs supports at meal is proposed. A feature of this system is that the robotic aid system can communicate with the operator using the speech recognition and speech synthesis functions. Another feature is that the robotic aid system uses an image processing, and by doing this the system can recognize the environmental situations of the dishes, cups and so on. Due to this image processing function, the operator does not need to specify the position and the posture of the dishes and target objects. Furthermore, combination communication between speech and image processing will enables a friendly man-machine to communicate with each other, since speech and visual information are essential in the human communication.

  3. Mechanical Implementation and Simulation of MoboLab, A Mobile Robot for Inspection of Power Transmission Lines

    Directory of Open Access Journals (Sweden)

    Mahmud Saadat Foumani

    2008-11-01

    Full Text Available This paper describes the first phase in development of a mobile robot that can navigate aerial power transmission lines completely unattended by human operator. Its ultimate purpose is to automate inspection of power transmission lines and their equipments. The authors have developed a scaled functional model of such a mobile robot with a preliminary simple computer based on-off controller. MoboLab (Mobile Laboratory navigates a power transmission line between two strain towers. It can maneuver over obstructions created by line equipments such as insulators, warning spheres, dampers, and spacer dampers. It can also easily negotiate the towers by its three flexible arms. MoboLab has an internal main screw which enables the robot to move itself or its two front and rear arms independently through changing gripped points. When the front arm gets close to an obstacle, the arm detaches from the line and goes down, the robot moves forward, the arm passes the obstacle and grippes the line again. In a same way another arms pass the obstacle.

  4. Motion and operation planning of robotic systems background and practical approaches

    CERN Document Server

    Gomez-Barvo, Fernando

    2015-01-01

    This book addresses the broad multi-disciplinary topic of robotics, and presents the basic techniques for motion and operation planning in robotics systems. Gathering contributions from experts in diverse and wide ranging fields, it offers an overview of the most recent and cutting-edge practical applications of these methodologies. It covers both theoretical and practical approaches, and elucidates the transition from theory to implementation. An extensive analysis is provided, including humanoids, manipulators, aerial robots and ground mobile robots. ‘Motion and Operation Planning of Robotic Systems’ addresses the following topics: *The theoretical background of robotics. *Application of motion planning techniques to manipulators, such as serial and parallel manipulators. *Mobile robots planning, including robotic applications related to aerial robots, large scale robots and traditional wheeled robots. *Motion planning for humanoid robots. An invaluable reference text for graduate students and researche...

  5. Vibrotactile feedback for conveying object shape information as perceived by artificial sensing of robotic arm.

    Science.gov (United States)

    Khasnobish, Anwesha; Pal, Monalisa; Sardar, Dwaipayan; Tibarewala, D N; Konar, Amit

    2016-08-01

    This work is a preliminary study towards developing an alternative communication channel for conveying shape information to aid in recognition of items when tactile perception is hindered. Tactile data, acquired during object exploration by sensor fitted robot arm, are processed to recognize four basic geometric shapes. Patterns representing each shape, classified from tactile data, are generated using micro-controller-driven vibration motors which vibrotactually stimulate users to convey the particular shape information. These motors are attached on the subject's arm and their psychological (verbal) responses are recorded to assess the competence of the system to convey shape information to the user in form of vibrotactile stimulations. Object shapes are classified from tactile data with an average accuracy of 95.21 %. Three successive sessions of shape recognition from vibrotactile pattern depicted learning of the stimulus from subjects' psychological response which increased from 75 to 95 %. This observation substantiates the learning of vibrotactile stimulation in user over the sessions which in turn increase the system efficacy. The tactile sensing module and vibrotactile pattern generating module are integrated to complete the system whose operation is analysed in real-time. Thus, the work demonstrates a successful implementation of the complete schema of artificial tactile sensing system for object-shape recognition through vibrotactile stimulations.

  6. System and method for controlling a vision guided robot assembly

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Yhu-Tin; Daro, Timothy; Abell, Jeffrey A.; Turner, III, Raymond D.; Casoli, Daniel J.

    2017-03-07

    A method includes the following steps: actuating a robotic arm to perform an action at a start position; moving the robotic arm from the start position toward a first position; determining from a vision process method if a first part from the first position will be ready to be subjected to a first action by the robotic arm once the robotic arm reaches the first position; commencing the execution of the visual processing method for determining the position deviation of the second part from the second position and the readiness of the second part to be subjected to a second action by the robotic arm once the robotic arm reaches the second position; and performing a first action on the first part using the robotic arm with the position deviation of the first part from the first position predetermined by the vision process method.

  7. Robotic refueling machine

    International Nuclear Information System (INIS)

    Challberg, R.C.; Jones, C.R.

    1996-01-01

    One of the longest critical path operations performed during the outage is removing and replacing the fuel. A design is currently under development for a refueling machine which would allow faster, fully automated operation and would also allow the handling of two fuel assemblies at the same time. This design is different from current designs, (a) because of its lighter weight, making increased acceleration and speed possible, (b) because of its control system which makes locating the fuel assembly more dependable and faster, and (c) because of its dual handling system allowing simultaneous fuel movements. The new design uses two robotic arms to span a designated area of the vessel and the fuel storage area. Attached to the end of each robotic arm is a lightweight telescoping mast with a pendant attached to the end of each mast. The pendant acts as the base unit, allowing attachment of any number of end effectors depending on the servicing or inspection operation. Housed within the pendant are two television cameras used for the positioning control system. The control system is adapted from the robotics field using the technology known as machine vision, which provides both object and character recognition techniques to enable relative position control rather than absolute position control as in past designs. The pendant also contains thrusters that are used for fast, short distance, precise positioning. The new refueling machine system design is capable of a complete off load and reload of an 872 element core in about 5.3 days compared to 13 days for a conventional system

  8. EVALUATING CONTINUOUS-TIME SLAM USING A PREDEFINED TRAJECTORY PROVIDED BY A ROBOTIC ARM

    Directory of Open Access Journals (Sweden)

    B. Koch

    2017-09-01

    Full Text Available Recently published approaches to SLAM algorithms process laser sensor measurements and output a map as a point cloud of the environment. Often the actual precision of the map remains unclear, since SLAMalgorithms apply local improvements to the resulting map. Unfortunately, it is not trivial to compare the performance of SLAMalgorithms objectively, especially without an accurate ground truth. This paper presents a novel benchmarking technique that allows to compare a precise map generated with an accurate ground truth trajectory to a map with a manipulated trajectory which was distorted by different forms of noise. The accurate ground truth is acquired by mounting a laser scanner on an industrial robotic arm. The robotic arm is moved on a predefined path while the position and orientation of the end-effector tool are monitored. During this process the 2D profile measurements of the laser scanner are recorded in six degrees of freedom and afterwards used to generate a precise point cloud of the test environment. For benchmarking, an offline continuous-time SLAM algorithm is subsequently applied to remove the inserted distortions. Finally, it is shown that the manipulated point cloud is reversible to its previous state and is slightly improved compared to the original version, since small errors that came into account by imprecise assumptions, sensor noise and calibration errors are removed as well.

  9. Evaluating Continuous-Time Slam Using a Predefined Trajectory Provided by a Robotic Arm

    Science.gov (United States)

    Koch, B.; Leblebici, R.; Martell, A.; Jörissen, S.; Schilling, K.; Nüchter, A.

    2017-09-01

    Recently published approaches to SLAM algorithms process laser sensor measurements and output a map as a point cloud of the environment. Often the actual precision of the map remains unclear, since SLAMalgorithms apply local improvements to the resulting map. Unfortunately, it is not trivial to compare the performance of SLAMalgorithms objectively, especially without an accurate ground truth. This paper presents a novel benchmarking technique that allows to compare a precise map generated with an accurate ground truth trajectory to a map with a manipulated trajectory which was distorted by different forms of noise. The accurate ground truth is acquired by mounting a laser scanner on an industrial robotic arm. The robotic arm is moved on a predefined path while the position and orientation of the end-effector tool are monitored. During this process the 2D profile measurements of the laser scanner are recorded in six degrees of freedom and afterwards used to generate a precise point cloud of the test environment. For benchmarking, an offline continuous-time SLAM algorithm is subsequently applied to remove the inserted distortions. Finally, it is shown that the manipulated point cloud is reversible to its previous state and is slightly improved compared to the original version, since small errors that came into account by imprecise assumptions, sensor noise and calibration errors are removed as well.

  10. Improvement of the operation of wheels mobile robot TRASMAR2

    International Nuclear Information System (INIS)

    Guerra C, D. A.; Tovar M, R.; Gonzalez M, J. L.; Segovia de los Rios, A.

    2013-10-01

    In the Instituto Nacional de Investigaciones Nucleares (ININ), personnel have been working in the development of wheels mobile robots for the surveillance and supervision of contaminated areas, and for the radioactive material transport. One of these achievements is the wheels mobile robot denominated TRASMAR2, which is sought that works in the tele operated form using net technologies, in particular, using a Web page by means of the client-servant technology. For this, diverse circuits and control programs have been development with the purpose that the robot carries out the movements that are required, being considered the use of sensors to avoid collisions. The different programs have been implemented in different micro controllers, and although the robot was working, is necessary to optimize and to concentrate these programs on a single micro controller. In this work are presented the analysis of the previously implemented programs, as the realized changes, including new programs required to improve the robot operation. As complement, was development and implemented an alternative proposal of the robot's tele operation by means of a Web page using Lab view, which is described in the work. With this proposal tele operate the robot was achieved, although its application is evaluating due to the resources that is consumes. (author)

  11. Development of an ITER relevant inspection robot

    Energy Technology Data Exchange (ETDEWEB)

    Gargiulo, L.; Bayetti, P.; Cordier, J.J.; Grisolia, C.; Hatchressian, J.C. [Association Euratom-CEA, Cadarache (France). Dept. de Recherche sur la Fusion Controlee; Friconneau, J.P.; Keller, D.; Perrot, Y. [CEA-LIST Robotics and Interactive Systems Unit, Fontenay aux Roses (France)

    2007-07-01

    Robotic operations are one of the major maintenance challenges for ITER and future fusion reactors. In particular, in vessel inspection operations without loss of conditioning could be very useful. Within this framework, the aim of the project called AIA (Articulated Inspection Arm) is to demonstrate the feasibility of a multi-purpose in-vessel Remote Handling inspection system using a long reach, limited payload carrier (up to 10 kg). It is composed of 5 segments with 11 degrees of freedom and a total range of 8 m. The project is currently developed by the CEA within the European workprogramme. Its first in situ tests are planned this summer on the Tore Supra tokamak at Cadarache (France). They will validate chosen concepts for operations under ITER relevant vacuum and temperature conditions. After qualification, the arm will constitute a promising tool for generic application. Several processes are already considered for ITER maintenance and will be demonstrated on the AIA robot carrier: - The first embedded process is the viewing system. It is currently being manufactured and will allow for close visual inspection of the complex Plasma Facing Components (limiters, neutralisers, RF antennae, diagnostic windows, etc.). - In situ localisation of leakage based on helium sniffer is also studied to improve maintenance operations. - Finally the laser ablation system for PFC detritiation, also developed in CEA laboratories, is being fitted to be implanted into the robot and put into operation in Tore Supra. This paper deals with the integration of the robot in the Tore Supra tokamak and the advances in the development of the listed processes. It also introduces the current test campaign aiming to qualify the robot performance and reliability under vacuum and temperature conditions. (orig.)

  12. Development of an ITER relevant inspection robot

    Energy Technology Data Exchange (ETDEWEB)

    Gargiulo, Laurent [Association Euratom-CEA, Departement de Recherche sur la Fusion Controlee, CE Cadarache 13108 (France)], E-mail: laurent.gargiulo@cea.fr; Bayetti, Pascal; Bruno, Vincent; Cordier, Jean-Jacques [Association Euratom-CEA, Departement de Recherche sur la Fusion Controlee, CE Cadarache 13108 (France); Friconneau, Jean-Pierre [CEA-LIST Robotics and Interactive Systems Unit, CE Fontenay Aux Roses (France); Grisolia, Christian; Hatchressian, Jean-Claude; Houry, Michael [Association Euratom-CEA, Departement de Recherche sur la Fusion Controlee, CE Cadarache 13108 (France); Keller, Delphine; Perrot, Yann [CEA-LIST Robotics and Interactive Systems Unit, CE Fontenay Aux Roses (France)

    2008-12-15

    Robotic operations are one of the major maintenance challenges for ITER and future fusion reactors. In particular, in-vessel inspection operations without loss of conditioning will be mandatory. In this context, an Articulated Inspection Arm (AIA) is currently developed by the CEA within the European work programme framework, which aims at demonstrating the feasibility of a multi-purpose in-vessel Remote Handling inspection system using a long reach, limited payload carrier (up to 10 kg). It is composed of 5 segments with 8 degrees of freedom and a total range of 8 m. The first in situ tests will take place by the end of 2007 on the Tore Supra Tokamak at Cadarache (France). They will validate concepts for operations under ITER relevant vacuum and temperature conditions. After qualification, the arm will constitute a promising tool for various applications. Several processes are already considered for ITER maintenance and will be demonstrated on the AIA robot carrier: - The first embedded process is the viewing system. It is already manufactured and will allow close visual inspection of the complex Plasma Facing Components (PFC) (limiters, neutralisers, RF antenna, diagnostic windows, etc.). - In situ localisation of water leakage based on a helium sniffing system is also being studied to improve and facilitate maintenance operations. - Finally a laser ablation system for PFC detritiation, developed in CEA laboratories, is being fitted to be implemented on the robot for future operation in Tore Supra. This paper deals with the integration of the robot into Tore Supra and the progress in the development of the processes listed above. It also describes the current test campaign aiming to qualify the robot performance and reliability under vacuum and temperature conditions.

  13. Development of an ITER relevant inspection robot

    International Nuclear Information System (INIS)

    Gargiulo, L.; Bayetti, P.; Cordier, J.J.; Grisolia, C.; Hatchressian, J.C.

    2007-01-01

    Robotic operations are one of the major maintenance challenges for ITER and future fusion reactors. In particular, in vessel inspection operations without loss of conditioning could be very useful. Within this framework, the aim of the project called AIA (Articulated Inspection Arm) is to demonstrate the feasibility of a multi-purpose in-vessel Remote Handling inspection system using a long reach, limited payload carrier (up to 10 kg). It is composed of 5 segments with 11 degrees of freedom and a total range of 8 m. The project is currently developed by the CEA within the European workprogramme. Its first in situ tests are planned this summer on the Tore Supra tokamak at Cadarache (France). They will validate chosen concepts for operations under ITER relevant vacuum and temperature conditions. After qualification, the arm will constitute a promising tool for generic application. Several processes are already considered for ITER maintenance and will be demonstrated on the AIA robot carrier: - The first embedded process is the viewing system. It is currently being manufactured and will allow for close visual inspection of the complex Plasma Facing Components (limiters, neutralisers, RF antennae, diagnostic windows, etc.). - In situ localisation of leakage based on helium sniffer is also studied to improve maintenance operations. - Finally the laser ablation system for PFC detritiation, also developed in CEA laboratories, is being fitted to be implanted into the robot and put into operation in Tore Supra. This paper deals with the integration of the robot in the Tore Supra tokamak and the advances in the development of the listed processes. It also introduces the current test campaign aiming to qualify the robot performance and reliability under vacuum and temperature conditions. (orig.)

  14. Development of an ITER relevant inspection robot

    International Nuclear Information System (INIS)

    Gargiulo, Laurent; Bayetti, Pascal; Bruno, Vincent; Cordier, Jean-Jacques; Friconneau, Jean-Pierre; Grisolia, Christian; Hatchressian, Jean-Claude; Houry, Michael; Keller, Delphine; Perrot, Yann

    2008-01-01

    Robotic operations are one of the major maintenance challenges for ITER and future fusion reactors. In particular, in-vessel inspection operations without loss of conditioning will be mandatory. In this context, an Articulated Inspection Arm (AIA) is currently developed by the CEA within the European work programme framework, which aims at demonstrating the feasibility of a multi-purpose in-vessel Remote Handling inspection system using a long reach, limited payload carrier (up to 10 kg). It is composed of 5 segments with 8 degrees of freedom and a total range of 8 m. The first in situ tests will take place by the end of 2007 on the Tore Supra Tokamak at Cadarache (France). They will validate concepts for operations under ITER relevant vacuum and temperature conditions. After qualification, the arm will constitute a promising tool for various applications. Several processes are already considered for ITER maintenance and will be demonstrated on the AIA robot carrier: - The first embedded process is the viewing system. It is already manufactured and will allow close visual inspection of the complex Plasma Facing Components (PFC) (limiters, neutralisers, RF antenna, diagnostic windows, etc.). - In situ localisation of water leakage based on a helium sniffing system is also being studied to improve and facilitate maintenance operations. - Finally a laser ablation system for PFC detritiation, developed in CEA laboratories, is being fitted to be implemented on the robot for future operation in Tore Supra. This paper deals with the integration of the robot into Tore Supra and the progress in the development of the processes listed above. It also describes the current test campaign aiming to qualify the robot performance and reliability under vacuum and temperature conditions

  15. A cable-driven soft robot surgical system for cardiothoracic endoscopic surgery: preclinical tests in animals.

    Science.gov (United States)

    Wang, Hesheng; Zhang, Runxi; Chen, Weidong; Wang, Xiaozhou; Pfeifer, Rolf

    2017-08-01

    Minimally invasive surgery attracts more and more attention because of the advantages of minimal trauma, less bleeding and pain and low complication rate. However, minimally invasive surgery for beating hearts is still a challenge. Our goal is to develop a soft robot surgical system for single-port minimally invasive surgery on a beating heart. The soft robot described in this paper is inspired by the octopus arm. Although the octopus arm is soft and has more degrees of freedom (DOFs), it can be controlled flexibly. The soft robot is driven by cables that are embedded into the soft robot manipulator and can control the direction of the end and middle of the soft robot manipulator. The forward, backward and rotation movement of the soft robot is driven by a propulsion plant. The soft robot can move freely by properly controlling the cables and the propulsion plant. The soft surgical robot system can perform different thoracic operations by changing surgical instruments. To evaluate the flexibility, controllability and reachability of the designed soft robot surgical system, some testing experiments have been conducted in vivo on a swine. Through the subxiphoid, the soft robot manipulator could enter into the thoracic cavity and pericardial cavity smoothly and perform some operations such as biopsy, ligation and ablation. The operations were performed successfully and did not cause any damage to the surrounding soft tissues. From the experiments, the flexibility, controllability and reachability of the soft robot surgical system have been verified. Also, it has been shown that this system can be used in the thoracic and pericardial cavity for different operations. Compared with other endoscopy robots, the soft robot surgical system is safer, has more DOFs and is more flexible for control. When performing operations in a beating heart, this system maybe more suitable than traditional endoscopy robots.

  16. Applying virtual reality to remote control of mobile robot

    Directory of Open Access Journals (Sweden)

    Chen Chin-Shan

    2017-01-01

    Full Text Available The purpose of this research is based on virtual reality to assisted pick and place tasks. Virtual reality can be utilized to control remote robot for pick and place element. The operator monitored and controlled the situation information of working site by Human Machine Interface. Therefore, we worked in harsh or dangerous environments that thing can be avoided. The procedure to operate mobile robot in virtual reality describes as follow: An experiment site with really experimental equipment is first established. Then, the experimental equipment and scene modeling are input to virtual reality for establishing a environment similar to the reality. Finally, the remote mobile robot is controlled to operate pick and place tasks through wireless communication by the object operation in virtual reality. The robot consists of a movable robot platform and robotic arm. The virtual reality is constructed by EON software; the Human Machine Interface is established by Visual Basic. The wireless connection is equipped the wireless Bluetooth, which is set the PC and PLC controller. With experimental tests to verify the robot in virtual reality and the wireless remote control, the robot could be operated and controlled to successfully complete pick and place tasks in reality by Human Machine Interface.

  17. ARM Operations and Engineering Procedure Mobile Facility Site Startup

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, Jimmy W

    2015-05-01

    This procedure exists to define the key milestones, necessary steps, and process rules required to commission and operate an Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF), with a specific focus toward on-time product delivery to the ARM Data Archive. The overall objective is to have the physical infrastructure, networking and communications, and instrument calibration, grooming, and alignment (CG&A) completed with data products available from the ARM Data Archive by the Operational Start Date milestone.

  18. Adaptive neural control for dual-arm coordination of humanoid robot with unknown nonlinearities in output mechanism.

    Science.gov (United States)

    Liu, Zhi; Chen, Ci; Zhang, Yun; Chen, C L P

    2015-03-01

    To achieve an excellent dual-arm coordination of the humanoid robot, it is essential to deal with the nonlinearities existing in the system dynamics. The literatures so far on the humanoid robot control have a common assumption that the problem of output hysteresis could be ignored. However, in the practical applications, the output hysteresis is widely spread; and its existing limits the motion/force performances of the robotic system. In this paper, an adaptive neural control scheme, which takes the unknown output hysteresis and computational efficiency into account, is presented and investigated. In the controller design, the prior knowledge of system dynamics is assumed to be unknown. The motion error is guaranteed to converge to a small neighborhood of the origin by Lyapunov's stability theory. Simultaneously, the internal force is kept bounded and its error can be made arbitrarily small.

  19. Autonomous mobile robotic system for supporting counterterrorist and surveillance operations

    Science.gov (United States)

    Adamczyk, Marek; Bulandra, Kazimierz; Moczulski, Wojciech

    2017-10-01

    Contemporary research on mobile robots concerns applications to counterterrorist and surveillance operations. The goal is to develop systems that are capable of supporting the police and special forces by carrying out such operations. The paper deals with a dedicated robotic system for surveillance of large objects such as airports, factories, military bases, and many others. The goal is to trace unauthorised persons who try to enter to the guarded area, document the intrusion and report it to the surveillance centre, and then warn the intruder by sound messages and eventually subdue him/her by stunning through acoustic effect of great power. The system consists of several parts. An armoured four-wheeled robot assures required mobility of the system. The robot is equipped with a set of sensors including 3D mapping system, IR and video cameras, and microphones. It communicates with the central control station (CCS) by means of a wideband wireless encrypted system. A control system of the robot can operate autonomously, and under remote control. In the autonomous mode the robot follows the path planned by the CCS. Once an intruder has been detected, the robot can adopt its plan to allow tracking him/her. Furthermore, special procedures of treatment of the intruder are applied including warning about the breach of the border of the protected area, and incapacitation of an appropriately selected very loud sound until a patrol of guards arrives. Once getting stuck the robot can contact the operator who can remotely solve the problem the robot is faced with.

  20. Conceptual design of an in-vessel inspection robotic system for Tokamak environment

    International Nuclear Information System (INIS)

    Kumar, Prabhat; Raju, Daniel; Ranjan, Vaibhav; Patel, Prateek; Dave, Jatinkumar; Naik, Mehul

    2013-01-01

    An in-vessel inspection robotic system has been conceptualized for operation inside a tokamak vessel. The robotic system is envisaged to comprise of a robotic arm, end-effector, microcontroller and wireless communication system. The end-effector is envisaged to be a special purpose camera for in-situ inspection between plasma shots. The three-link robotic arm, designed for ITER-like environment, has 4 revolute joints- 3 providing manipulation in poloidal plane and the fourth one providing limited movement in adjacent toroidal planes. This paper provides the conceptual design of the system along with kinematic analysis of robotic arm. Solutions have been derived for forward and inverse kinematic models and the Jacobian matrix for the robotic arm linkage. In forward kinematic model, given a set of joint-link parameters, the position and orientation of end-effector are determined with respect to a reference frame. In inverse kinematic model, given the specified position and orientation of end-effector with respect to a reference frame, a set of joint variables are derived that would bring the end-effector into the required posture. Using Jacobian matrix, the relation between the end-effector velocity and the joint velocity of a manipulator is obtained i.e. given the individual joint velocity; the end-effector velocity is obtained. A CAD model has been generated using CATIA to simulate the kinematic model and carry out computational stress analysis. (author)

  1. The development of graphic simulation technology for tele-operated robot

    International Nuclear Information System (INIS)

    Kim, Chang Hoi; Kim, Seung Ho; Kim, Ki Ho; Jung, Seung Ho; Hwang, Suk Yeoung; Kim, Byung Soo; Seo, Yong Chil; Lee, Young Kwang

    1998-02-01

    In hostile environments like a nuclear power plant, human access is limited to the strict minimum due to the high-level of radiation. The design of tele-robotic system requires careful preparation because of the nature of its safety. Also, the human operator should have a capability of supervising the robot system and responding promptly to the unexpected events. In this study, the graphic simulation technology has been developed to construct tele-robotic system which can effectively perform the specified tasks in nuclear facilities. The developed graphic simulator utilizes the Indigo 2 workstation of Silicon Graphics as a main computer and its software is written in the OpenGL graphic library in X windows environments. The developed simulator, interfaced with the control system of the real robot through the ethernet, acts as a supervisory controller. Since clear and concise visual information on real robot posture and task environments can be processed in real time, the efficiency of tele-operation can be remarkably enhanced with this simulator. This simulator using advanced 3 dimensional graphics has many advantages of modeling complicated shapes of robot and constructing the virtual work environments similar to the real ones. With the use of this developed simulator, the operator can evaluate the performance of the tele-robot before it is put into real operation. This system can prevents the possible disaster of the robot resulting from the collision with its work environments. (author). 9 refs., 23 tabs., 13 figs

  2. An Intuitive Robot Teleoperation System for Nuclear Power Plant Decommissioning

    International Nuclear Information System (INIS)

    Lee, Chang-hyuk; Gu, Taehyeong; Lee, Kyung-min; Ye, Sung-Joon; Bang, Young-bong

    2017-01-01

    A robot teleoperation system consists of a master device and a slave robot. The master device senses human intention and delivers it to the salve robot. A haptic device and an exoskeletal robot are widely used as the master device. The slave robot carries out operations delivered by the master device. It should guarantee enough degree of freedom (DOF) to perform the instructed operation and mobility in the environment inside the nuclear plant, such as flat surfaces and stairs. A 7-DOF robotic arm is commonly used as the slave device. This paper proposed a robot teleoperation system for nuclear power plant decommissioning. It discussed an experiment that was performed to validate the system's usability. The operator wearing the exoskeletal master device at the master site controlled the slave robot enabling it to move on a flat surface, climb/descend stairs, and move obstacles. The proposed robot teleoperation system can also be used in hazardous working environments where the use of such robots would be beneficial to human health and safety. In the future, research studies on the protection against radiation that damages the slave robot should be conducted.

  3. Robotic-assisted partial nephrectomy: surgical technique using a 3-arm approach and sliding-clip renorrhaphy

    Directory of Open Access Journals (Sweden)

    Jose M. Cabello

    2009-04-01

    Full Text Available INTRODUCTION: For the treatment of renal tumors, minimally invasive nephron-sparing surgery has become increasingly performed due to proven efficiency and excellent functional and oncological outcomes. The introduction of robotics into urologic laparoscopic surgery has allowed surgeons to perform challenging procedures in a reliable and reproducible manner. We present our surgical technique for robotic assisted partial nephrectomy (RPN using a 3-arm approach, including a sliding-clip renorrhaphy. MATERIAL AND METHODS: Our RPN technique is presented which describes the trocar positioning, hilar dissection, tumor identification using intraoperative ultrasound for margin determination, selective vascular clamping, tumor resection, and reconstruction using a sliding-clip technique. CONCLUSION: RPN using a sliding-clip renorrhaphy is a valid and reproducible surgical technique that reduces the challenge of the procedure by taking advantage of the enhanced visualization and control afforded by the robot. The renorrhaphy described is performed under complete control of the console surgeon, and has demonstrated a reduction in the warm ischemia times in our series.

  4. A reliability study on brain activation during active and passive arm movements supported by an MRI-compatible robot.

    Science.gov (United States)

    Estévez, Natalia; Yu, Ningbo; Brügger, Mike; Villiger, Michael; Hepp-Reymond, Marie-Claude; Riener, Robert; Kollias, Spyros

    2014-11-01

    In neurorehabilitation, longitudinal assessment of arm movement related brain function in patients with motor disability is challenging due to variability in task performance. MRI-compatible robots monitor and control task performance, yielding more reliable evaluation of brain function over time. The main goals of the present study were first to define the brain network activated while performing active and passive elbow movements with an MRI-compatible arm robot (MaRIA) in healthy subjects, and second to test the reproducibility of this activation over time. For the fMRI analysis two models were compared. In model 1 movement onset and duration were included, whereas in model 2 force and range of motion were added to the analysis. Reliability of brain activation was tested with several statistical approaches applied on individual and group activation maps and on summary statistics. The activated network included mainly the primary motor cortex, primary and secondary somatosensory cortex, superior and inferior parietal cortex, medial and lateral premotor regions, and subcortical structures. Reliability analyses revealed robust activation for active movements with both fMRI models and all the statistical methods used. Imposed passive movements also elicited mainly robust brain activation for individual and group activation maps, and reliability was improved by including additional force and range of motion using model 2. These findings demonstrate that the use of robotic devices, such as MaRIA, can be useful to reliably assess arm movement related brain activation in longitudinal studies and may contribute in studies evaluating therapies and brain plasticity following injury in the nervous system.

  5. Reduced-port robotic total mesorectal resection for rectal cancer using a single-port access: a technical note.

    Science.gov (United States)

    Bae, Sung Uk; Jeong, Woon Kyung; Baek, Seong Kyu

    2017-12-01

    Single-port laparoscopic surgery has some advantages, including improved cosmetic outcomes and minimized parietal trauma. However, pure single-port laparoscopic rectal cancer surgery is challenging because of the difficulties in creating triangulation and applying the laparoscopic staplers with sufficient distal margins in the narrow pelvic cavity. Recently, a reduced-port robotic operation with a robotic single-port access plus one wristed robotic arm for colon cancer was introduced to overcome the limitations of single-port laparoscopic rectal surgery. Single-port laparoscopic surgery has some advantages, including improved cosmetic outcomes and minimized parietal trauma. However, the pure single-port laparoscopic rectal cancer operation is challenging. Recently, a reduced-port robotic operation with a robotic single-port access plus one wristed robotic arm for colon cancer was introduced to overcome the limitations of single-port laparoscopic rectal surgery. We performed a single-port plus an additional port robotic operation using a robotic single-port access through the umbilical incision, and the wristed robotic instruments were inserted through an additional robotic port in the right lower quadrant. The total operative and docking times were 310 min and 25 min, respectively. The total number of lymph nodes harvested was 12, and the proximal and distal resection margins were 11.1 and 2 cm, respectively. The patient was discharged on postoperative day 12 uneventfully. Based on a representative case, reduced-port robotic total mesorectal excision for rectal cancer using the single-port access appears to be feasible and safe. This approach could overcome the limitations of single-port laparoscopic rectal surgery.

  6. Design and testing of a model CELSS chamber robot

    Science.gov (United States)

    Davis, Mark; Dezego, Shawn; Jones, Kinzy; Kewley, Christopher; Langlais, Mike; McCarthy, John; Penny, Damon; Bonner, Tom; Funderburke, C. Ashley; Hailey, Ruth

    1994-08-01

    A robot system for use in an enclosed environment was designed and tested. The conceptual design will be used to assist in research performed by the Controlled Ecological Life Support System (CELSS) project. Design specifications include maximum load capacity, operation at specified environmental conditions, low maintenance, and safety. The robot system must not be hazardous to the sealed environment, and be capable of stowing and deploying within a minimum area of the CELSS chamber facility. This design consists of a telescoping robot arm that slides vertically on a shaft positioned in the center of the CELSS chamber. The telescoping robot arm consists of a series of links which can be fully extended to a length equal to the radius of the working envelope of the CELSS chamber. The vertical motion of the robot arm is achieved through the use of a combination ball screw/ball spline actuator system. The robot arm rotates cylindrically about the vertical axis through use of a turntable bearing attached to a central mounting structure fitted to the actuator shaft. The shaft is installed in an overhead rail system allowing the entire structure to be stowed and deployed within the CELSS chamber. The overhead rail system is located above the chamber's upper lamps and extends to the center of the CELSS chamber. The mounting interface of the actuator shaft and rail system allows the entire actuator shaft to be detached and removed from the CELSS chamber. When the actuator shaft is deployed, it is held fixed at the bottom of the chamber by placing a square knob on the bottom of the shaft into a recessed square fitting in the bottom of the chamber floor. A support boot ensures the rigidity of the shaft. Three student teams combined into one group designed a model of the CELSS chamber robot that they could build. They investigated materials, availability, and strength in their design. After the model arm and stand were built, the class performed pre-tests on the entire system

  7. micROS: a morphable, intelligent and collective robot operating system.

    Science.gov (United States)

    Yang, Xuejun; Dai, Huadong; Yi, Xiaodong; Wang, Yanzhen; Yang, Shaowu; Zhang, Bo; Wang, Zhiyuan; Zhou, Yun; Peng, Xuefeng

    2016-01-01

    Robots are developing in much the same way that personal computers did 40 years ago, and robot operating system is the critical basis. Current robot software is mainly designed for individual robots. We present in this paper the design of micROS, a morphable, intelligent and collective robot operating system for future collective and collaborative robots. We first present the architecture of micROS, including the distributed architecture for collective robot system as a whole and the layered architecture for every single node. We then present the design of autonomous behavior management based on the observe-orient-decide-act cognitive behavior model and the design of collective intelligence including collective perception, collective cognition, collective game and collective dynamics. We also give the design of morphable resource management, which first categorizes robot resources into physical, information, cognitive and social domains, and then achieve morphability based on self-adaptive software technology. We finally deploy micROS on NuBot football robots and achieve significant improvement in real-time performance.

  8. Message Encryption in Robot Operating System: Collateral Effects of Hardening Mobile Robots

    Directory of Open Access Journals (Sweden)

    Francisco J. Rodríguez-Lera

    2018-03-01

    Full Text Available In human–robot interaction situations, robot sensors collect huge amounts of data from the environment in order to characterize the situation. Some of the gathered data ought to be treated as private, such as medical data (i.e., medication guidelines, personal, and safety information (i.e., images of children, home habits, alarm codes, etc.. However, most robotic software development frameworks are not designed for securely managing this information. This paper analyzes the scenario of hardening one of the most widely used robotic middlewares, Robot Operating System (ROS. The study investigates a robot’s performance when ciphering the messages interchanged between ROS nodes under the publish/subscribe paradigm. In particular, this research focuses on the nodes that manage cameras and LIDAR sensors, which are two of the most extended sensing solutions in mobile robotics, and analyzes the collateral effects on the robot’s achievement under different computing capabilities and encryption algorithms (3DES, AES, and Blowfish to robot performance. The findings present empirical evidence that simple encryption algorithms are lightweight enough to provide cyber-security even in low-powered robots when carefully designed and implemented. Nevertheless, these techniques come with a number of serious drawbacks regarding robot autonomy and performance if they are applied randomly. To avoid these issues, we define a taxonomy that links the type of ROS message, computational units, and the encryption methods. As a result, we present a model to select the optimal options for hardening a mobile robot using ROS.

  9. Teaching Joint-Level Robot Programming with a New Robotics Software Tool

    Directory of Open Access Journals (Sweden)

    Fernando Gonzalez

    2017-12-01

    Full Text Available With the rising popularity of robotics in our modern world there is an increase in the number of engineering programs that offer the basic Introduction to Robotics course. This common introductory robotics course generally covers the fundamental theory of robotics including robot kinematics, dynamics, differential movements, trajectory planning and basic computer vision algorithms commonly used in the field of robotics. Joint programming, the task of writing a program that directly controls the robot’s joint motors, is an activity that involves robot kinematics, dynamics, and trajectory planning. In this paper, we introduce a new educational robotics tool developed for teaching joint programming. The tool allows the student to write a program in a modified C language that controls the movement of the arm by controlling the velocity of each joint motor. This is a very important activity in the robotics course and leads the student to gain knowledge of how to build a robotic arm controller. Sample assignments are presented for different levels of difficulty.

  10. Embedded mobile farm robot for identification of diseased plants

    Science.gov (United States)

    Sadistap, S. S.; Botre, B. A.; Pandit, Harshavardhan; Chandrasekhar; Rao, Adesh

    2013-07-01

    This paper presents the development of a mobile robot used in farms for identification of diseased plants. It puts forth two of the major aspects of robotics namely automated navigation and image processing. The robot navigates on the basis of the GPS (Global Positioning System) location and data obtained from IR (Infrared) sensors to avoid any obstacles in its path. It uses an image processing algorithm to differentiate between diseased and non-diseased plants. A robotic platform consisting of an ARM9 processor, motor drivers, robot mechanical assembly, camera and infrared sensors has been used. Mini2440 microcontroller has been used wherein Embedded linux OS (Operating System) is implemented.

  11. Quadruped robot for improving workability at hazardous environment. Development of load carriage function

    International Nuclear Information System (INIS)

    Matsuzaki, Kenji; Ueda, Koji; Suganuma, Naotaka; Uehara, Takuya; Nakamura, Norihito; Mitsuya, Yusuke

    2015-01-01

    The working area and working time are restricted for human under hazardous environment such as high radiation environment or disaster sites. For this reason, we have developed a remotely operated quadruped robot which can walk on uneven terrain such as stairs and slopes. We focused attention on using this robot for carrying various tools and materials for decommissioning work to enlarge workability in hazardous environment instead of personnel. When the arm for handling loads is mounted on the robot, the conveyable load is decreased by weight of the arm. Therefore, we realized unloading task using two of its legs as handling arms. This enables to carry the load which is equal to the maximum payload of the robot. Since the leg tip of this robot is not designed to handle objects, the lifting lug whose shape fits the leg tip was attached to the carrying tray. This unloading task was validated by simulation and experiments. Moreover, we have developed stable walking control method on unsteady or uneven terrain such as rubbles by dynamically keeping balance using posture sensors. This control method can improve robustness of walk with loads, and enhanced practicality of this robot. (author)

  12. Optimized Assistive Human-Robot Interaction Using Reinforcement Learning.

    Science.gov (United States)

    Modares, Hamidreza; Ranatunga, Isura; Lewis, Frank L; Popa, Dan O

    2016-03-01

    An intelligent human-robot interaction (HRI) system with adjustable robot behavior is presented. The proposed HRI system assists the human operator to perform a given task with minimum workload demands and optimizes the overall human-robot system performance. Motivated by human factor studies, the presented control structure consists of two control loops. First, a robot-specific neuro-adaptive controller is designed in the inner loop to make the unknown nonlinear robot behave like a prescribed robot impedance model as perceived by a human operator. In contrast to existing neural network and adaptive impedance-based control methods, no information of the task performance or the prescribed robot impedance model parameters is required in the inner loop. Then, a task-specific outer-loop controller is designed to find the optimal parameters of the prescribed robot impedance model to adjust the robot's dynamics to the operator skills and minimize the tracking error. The outer loop includes the human operator, the robot, and the task performance details. The problem of finding the optimal parameters of the prescribed robot impedance model is transformed into a linear quadratic regulator (LQR) problem which minimizes the human effort and optimizes the closed-loop behavior of the HRI system for a given task. To obviate the requirement of the knowledge of the human model, integral reinforcement learning is used to solve the given LQR problem. Simulation results on an x - y table and a robot arm, and experimental implementation results on a PR2 robot confirm the suitability of the proposed method.

  13. MODULAR MANIPULATOR FOR ROBOTICS APPLICATIONS

    International Nuclear Information System (INIS)

    Geisinger, Joseph W. Ph.D.

    2001-01-01

    ARM Automation, Inc. is developing a FR-amework of modular actuators that can address the DOE's wide range of robotics needs. The objective of this effort is to demonstrate the effectiveness of this technology by constructing a manipulator FR-om these actuators within a glovebox for Automated Plutonium Processing (APP). At the end of the project, the system of actuators was used to construct several different manipulator configurations, which accommodate common glovebox tasks such as repackaging. The modular nature and quickconnects of this system simplify installation into ''hot'' boxes and any potential modifications or repair therein. This work focused on the development of self-contained robotic actuator modules including the embedded electronic controls for the purpose of building a manipulator system. Both of the actuators developed under this project contain the control electronics, sensors, motor, gear train, wiring, system communications and mechanical interfaces of a complete robotics servo device. Test actuators and accompanying DISC(trademark)s underwent validation testing at The University of Texas at Austin and ARM Automation, Inc. following final design and fabrication. The system also included custom links, an umbilical cord, an open architecture PC-based system controller, and operational software that permitted integration into a completely functional robotic manipulator system. The open architecture on which this system is based avoids proprietary interfaces and communication protocols which only serve to limit the capabilities and flexibility of automation equipment. The system was integrated and tested in the contractor's facility for intended performance and operations. The manipulator was tested using the full-scale equipment and process mock-ups. The project produced a practical and operational system including a quantitative evaluation of its performance and cost

  14. Robotic fabrication in architecture, art, and design

    CERN Document Server

    Braumann, Johannes

    2013-01-01

    Architects, artists, and designers have been fascinated by robots for many decades, from Villemard’s utopian vision of an architect building a house with robotic labor in 1910, to the design of buildings that are robots themselves, such as Archigram’s Walking City. Today, they are again approaching the topic of robotic fabrication but this time employing a different strategy: instead of utopian proposals like Archigram’s or the highly specialized robots that were used by Japan’s construction industry in the 1990s, the current focus of architectural robotics is on industrial robots. These robotic arms have six degrees of freedom and are widely used in industry, especially for automotive production lines. What makes robotic arms so interesting for the creative industry is their multi-functionality: instead of having to develop specialized machines, a multifunctional robot arm can be equipped with a wide range of end-effectors, similar to a human hand using various tools. Therefore, architectural researc...

  15. Emergency response mobile robot for operations in combustible atmospheres

    Science.gov (United States)

    Stone, Henry W. (Inventor); Ohm, Timothy R. (Inventor)

    1995-01-01

    A mobile, self-powered, self-contained, and remote-controlled robot is presented. The robot is capable of safely operating in a combustible atmosphere and providing information about the atmosphere to the operator. The robot includes non-sparking and non-arcing electro-mechanical and electronic components designed to prevent the robot from igniting the combustible atmosphere. The robot also includes positively pressurized enclosures that house the electromechanical and electronic components of the robot and prevent intrusion of the combustible atmosphere into the enclosures. The enclosures are interconnected such that a pressurized gas injected into any one of the enclosures is routed to all the other enclosures through the interconnections. It is preferred that one or more sealed internal channels through structures intervening between the enclosures be employed. Pressure transducers for detecting if the pressure within the enclosures falls below a predetermined level are included. The robot also has a sensing device for determining the types of combustible substances in the surrounding atmosphere, as well as the concentrations of each type of substance relative to a pre-determined lower explosive limit (LEL). In addition, the sensing device can determine the percent level of oxygen present in the surrounding atmosphere.

  16. Advance of Hazardous Operation Robot and its Application in Special Equipment Accident Rescue

    Science.gov (United States)

    Zeng, Qin-Da; Zhou, Wei; Zheng, Geng-Feng

    A survey of hazardous operation robot is given out in this article. Firstly, the latest researches such as nuclear industry robot, fire-fighting robot and explosive-handling robot are shown. Secondly, existing key technologies and their shortcomings are summarized, including moving mechanism, control system, perceptive technology and power technology. Thirdly, the trend of hazardous operation robot is predicted according to current situation. Finally, characteristics and hazards of special equipment accident, as well as feasibility of hazardous operation robot in the area of special equipment accident rescue are analyzed.

  17. Dual Arm Work Platform teleoperated robotics system. Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-12-01

    The US Department of Energy (DOE) and the Federal Energy Technology Center (FETC) has developed a Large Scale Demonstration Project (LSDP) at the Chicago Pile-5 Research Reactor (CP-5) at Argonne National Laboratory-East (ANL). The objective of the LSDP is to demonstrate potentially beneficial Deactivation and Decommissioning (D and D) technologies in comparison with current baseline technologies. The Dual Arm Work Platform (DAWP) demonstration focused on the use of the DAWP to segment and dismantle the CP-5 reactor tank and surrounding bio-shield components (including the graphite block reflector, lead and boral sheeting) and performing some minor tasks best suited for the use of teleoperated robotics that were not evaluated in this demonstration. The DAWP system is not a commercially available product at this time. The CP-5 implementation was its first D and D application. The demonstration of the DAWP was to determine the areas on which improvements must be made to make this technology commercially viable. The results of the demonstration are included in this greenbook. It is the intention of the developers to incorporate lessons learned at this demonstration and current technological advancements in robotics into the next generation of the DAWP

  18. Fiscal 2000 report on result of R and D on robot system cooperating and coexisting with human beings. Development of energy conservation technology; 2000 nendo ningen kyocho kyozongata robot system kenkyu kaihatsu seika hokokusho. Energy shiyo gorika gijutsu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-06-01

    Introduction of a number of robots and consumption of a large amount of energy are unavoidable if a complicated process operation is to be carried out by robots in an extensive work site. Great energy conservation is contrived by developing robots applicable to manufacturing in performing a variety of operations in place of human beings and thereby reducing the number of robots to work. This paper explains the fiscal 2000 results. For dual-handed cooperative tasks, a function was examined capable of gripping an object without giving a humanoid robot an instruction of an exact gripping position. A method was designed to prepare a command for the other arm through a command for one arm, with torque impedance control employed for the purpose of avoiding damage due to collision. A study was conducted on a three-dimensional shape detecting model using a visual device of a robot. In grasping problems of balance control of a humanoid robot, the behavior of a robot consisting of multi-links was considered as behavior of inverted pendulum, with possibility checked for the stabilization of the balance. For the purpose of putting the virtual robot platform previously developed to practical use, a three-dimensional operation tool of run-time user interface was developed, with research conducted on the sophistication of robot application. (NEDO)

  19. The potential of laser cutting and snake arm robots in aspects of nuclear decommissioning

    International Nuclear Information System (INIS)

    Hilton, Paul; Khan, Ali

    2013-01-01

    This paper will describe recent work conducted in the UK to highlight the potential of applying high power laser cutting to aspects of decommissioning and dismantling in the nuclear sector. A major driver for this activity is size reduction of metallic structures, vessels and tubing, with the objective of efficient stacking of the cut parts for future long term storage. TWI have used a standard 5 kW multi-mode laser with fibre optic delivery of the beam, to demonstrate techniques for cutting stainless steel tubing, at diameters up to 150 mm and wall thicknesses up to 7 mm, and various thicknesses of plate materials. Using specially developed cutting heads, employing long focal length lenses to form the beam, techniques were developed to allow the cutting of tubes from one side only and without changing the focal position of the laser beam with respect to the diameter of the tube perpendicular to the incident beam. The latter means that remote programming of the cutting path becomes much simpler. For cutting plate materials, special gas nozzle dynamics have produced great tolerance of the cutting process to stand-off distance (the distance between the surface of the material being cut and the exit of the cutting nozzle). One particularly interesting method of remote deployment of these cutting techniques is to use 'snake arm' robots. These robots, by nature of their construction, can access areas un-accessible using other techniques. This of course makes them particularly suited to aspects of nuclear decommissioning, particularly in what are termed 'un-structured environments', where the exact disposition of items encountered is not known. The paper will also describe the first time a laser cutting head has been installed on the end of a snake arm robot and the combination used in a simulated nuclear cutting application. (author)

  20. The development of advanced robotics for the nuclear industry -The development of robotic system for the nuclear power plants-

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Hoh; Kim, Chang Heui; Kim, Byung Soo; Hwang, Suk Yong; Kim, Kee Hoh; Lee, Jae Kyung; Lee, Yung Kwang; Suh, Yong Chil; Lee, Yong Bum; Kim, Woong Kee; Park, Soon Yong [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    The Advanced Robotics Department of the Korea Atomic Energy Research Institute (KAERI) is developing a Dexterous Manipulation System (DMS) and a teleoperated mobile robot, identified as KAEROT/ml, for use in nuclear power plants. The DMS is being developed for performing tasks such as the opening and closing of nozzle dam inside water chamber of steam generator. The DMS has two major subsystems; a master-slave 6 degrees of freedom (dof) manipulator and a support device. The master-slave arms are designed dissimilar kinematically and dynamically, and their functions are performed by a bilateral force-reflecting force control. The slave is a hydraulically powered arm with a 3 dof end effector, and is mounted on the top of the support device for nozzle dam operation. The support device guides the slave arm into the water chamber and supports it during its operation. The DMS can be operated either in teleoperated or supervisory control modes. The KAEROT/ml is designed to be used in emergency response applications such as monitoring and mapping radiation areas, handling radioactive materials and performing decontamination tasks. The KAEROT/ml equipped with four-omnidirectional planetary wheels has a 6 dof joint-controlled arm and is capable of ascending and descending stairs and navigating flat surface with zero turning radius. This report describes the mechanical design, features, modeling and control system of both the DMS and the KAEROT/ml. 209 figs, 49 pix, 69 tabs, 62 refs. (Author).

  1. The development of advanced robotics for the nuclear industry -The development of robotic system for the nuclear power plants-

    International Nuclear Information System (INIS)

    Kim, Seung Hoh; Kim, Chang Heui; Kim, Byung Soo; Hwang, Suk Yong; Kim, Kee Hoh; Lee, Jae Kyung; Lee, Yung Kwang; Suh, Yong Chil; Lee, Yong Bum; Kim, Woong Kee; Park, Soon Yong

    1995-07-01

    The Advanced Robotics Department of the Korea Atomic Energy Research Institute (KAERI) is developing a Dexterous Manipulation System (DMS) and a teleoperated mobile robot, identified as KAEROT/ml, for use in nuclear power plants. The DMS is being developed for performing tasks such as the opening and closing of nozzle dam inside water chamber of steam generator. The DMS has two major subsystems; a master-slave 6 degrees of freedom (dof) manipulator and a support device. The master-slave arms are designed dissimilar kinematically and dynamically, and their functions are performed by a bilateral force-reflecting force control. The slave is a hydraulically powered arm with a 3 dof end effector, and is mounted on the top of the support device for nozzle dam operation. The support device guides the slave arm into the water chamber and supports it during its operation. The DMS can be operated either in teleoperated or supervisory control modes. The KAEROT/ml is designed to be used in emergency response applications such as monitoring and mapping radiation areas, handling radioactive materials and performing decontamination tasks. The KAEROT/ml equipped with four-omnidirectional planetary wheels has a 6 dof joint-controlled arm and is capable of ascending and descending stairs and navigating flat surface with zero turning radius. This report describes the mechanical design, features, modeling and control system of both the DMS and the KAEROT/ml. 209 figs, 49 pix, 69 tabs, 62 refs. (Author)

  2. Unilateral versus bilateral robot-assisted rehabilitation on arm-trunk control and functions post stroke: a randomized controlled trial.

    Science.gov (United States)

    Wu, Ching-Yi; Yang, Chieh-Ling; Chen, Ming-de; Lin, Keh-Chung; Wu, Li-Ling

    2013-04-12

    Although the effects of robot-assisted arm training after stroke are promising, the relative effects of unilateral (URT) vs. bilateral (BRT) robot-assisted arm training remain uncertain. This study compared the effects of URT vs. BRT on upper extremity (UE) control, trunk compensation, and function in patients with chronic stroke. This was a single-blinded, randomized controlled trial. The intervention was implemented at 4 hospitals. Fifty-three patients with stroke were randomly assigned to URT, BRT, or control treatment (CT). Each group received UE training for 90 to 105 min/day, 5 days/week, for 4 weeks. The kinematic variables for arm motor control and trunk compensation included normalized movement time, normalized movement units, and the arm-trunk contribution slope in unilateral and bilateral tasks. Motor function and daily function were measured by the Wolf Motor Function Test (WMFT), Motor Activity Log (MAL), and ABILHAND Questionnaire. The BRT and CT groups elicited significantly larger slope values (i.e., less trunk compensation) at the start of bilateral reaching than the URT group. URT led to significantly better effects on WMFT-Time than BRT. Differences in arm control kinematics and performance on the MAL and ABILHAND among the 3 groups were not significant. BRT and URT resulted in differential improvements in specific UE/trunk performance in patients with stroke. BRT elicited larger benefits than URT on reducing compensatory trunk movements at the beginning of reaching. In contrast, URT produced better improvements in UE temporal efficiency. These relative effects on movement kinematics, however, did not translate into differential benefits in daily functions. ClinicalTrials.gov: NCT00917605.

  3. Lessons learned from the STS-120/ISS 10A robotics operations

    Science.gov (United States)

    Aziz, Sarmad

    2010-01-01

    The STS-120/ISS 10A assembly mission was an unprecedented period during the life of the International Space Stations (ISS). The successful completion of the mission laid the foundation for the launch of the European and Japanese laboratories and continued assembly of the station. Unlike previous missions that concluded when the Space Shuttle undocked from the ISS, the 10A mission required critical assembly operations to continue after the Shuttle's departure to relocate the Harmony module to its permanent location and activate its systems. The end-to-end mission lasted for almost a month and required the execution of seven space walks, over 20 major robotics operations, and countless hours of ground commanding. The Canadian built mobile servicing system (MSS) and its robotics space station remote manipulator system (SSRMS) played a key a role in the success of the assembly operations. The mission presented the ISS robotics flight control team (ROBO) with unique challenges during the pre-mission planning and real-time execution of complex assembly tasks. The mission included the relocation of the P6 truss segment from the Z1 Node to its permanent location on the P5 truss; a three day marathon of highly choreographed sequence of robotics operations and space walks, and the reconfiguration of ISS structure to attach Harmony (Node 2) to the US destiny laboratory module; a six day sequence of complex robotics operations the majority of which was executed after the departure of the shuttle and included an unprecedented amount of ground commanded robotics operations. Of all the robotics operations executed during the mission, none were more challenging than supporting the repair of a torn P6 solar array that was damaged during its deployment; a dramatic space walk that pushed the MSS and the robotics flight control team to new limits and required the real-time planning and execution of an intricate series of operations that spanned two days. This paper will present an

  4. Optimalisasi Ukuran Manipulabilitas Robot Stanford Menggunakan Metode Pseudo-inverse

    OpenAIRE

    admin, Gina Fahrina

    2013-01-01

    Robot is one of the most important element in the industrial world which has been growing very rapidly. Stanford robot arm is one of robot that use in industry, it has five degrees of freedom (DOF). Movement of the robot arm in his workspace called manipulability or manipulability measure. More the optimal manipulability measure manipulator, the more movement of the robotic arm will be more flexible in his workspace. The purpose of this research are to get knowledge and learn how to solve inv...

  5. Implantación de un Controlador para la Cinemática Inversa del Brazo Robot Mitsubishi RV-2AJ a través de una Tarjeta ARM y MatLab

    OpenAIRE

    Cajamarca Peñafiel, Jorge Andres; Portilla Vargas, Alexis David

    2016-01-01

    The project involves the design and construction of a controller for handling the inverse and forward kinematics of the robot Mitsubishi RV-2AJ arm, it is located in the laboratories of the Salesian University in order to create a direct communication through an external card ARM and MatLab software. This driver allows the user to manipulate the robot arm Mitsubishi RV-2AJ in two categories, by joints and coordinates, with a compact hardware and easy to use interface, the autonomy is given...

  6. An Augmented Discrete-Time Approach for Human-Robot Collaboration

    Directory of Open Access Journals (Sweden)

    Peidong Liang

    2016-01-01

    Full Text Available Human-robot collaboration (HRC is a key feature to distinguish the new generation of robots from conventional robots. Relevant HRC topics have been extensively investigated recently in academic institutes and companies to improve human and robot interactive performance. Generally, human motor control regulates human motion adaptively to the external environment with safety, compliance, stability, and efficiency. Inspired by this, we propose an augmented approach to make a robot understand human motion behaviors based on human kinematics and human postural impedance adaptation. Human kinematics is identified by geometry kinematics approach to map human arm configuration as well as stiffness index controlled by hand gesture to anthropomorphic arm. While human arm postural stiffness is estimated and calibrated within robot empirical stability region, human motion is captured by employing a geometry vector approach based on Kinect. A biomimetic controller in discrete-time is employed to make Baxter robot arm imitate human arm behaviors based on Baxter robot dynamics. An object moving task is implemented to validate the performance of proposed methods based on Baxter robot simulator. Results show that the proposed approach to HRC is intuitive, stable, efficient, and compliant, which may have various applications in human-robot collaboration scenarios.

  7. The development of robot application technology in nuclear facilities

    International Nuclear Information System (INIS)

    Lee, Jong Min; Kim, Seung Ho; Kim, Chang Hoi; Kim, Byung Soo; Hwang, Suk Young; Sohn, Surg Won; Lee, Yong Bum; Kim, Woong Ki

    1991-01-01

    The project of this study is intended to develop the application technology for autonomous robotic systems operated in hostile environments where human access is prohibited. The mobile robot, named as KAEROT, has been designed by adopting the controller of multiprocessor of distributed system architecture in order to get flexibility. 2 driving wheel assembles and 1 steering mechanism has been adopted and each of them is made of planetary wheel which is composed of a couple of star-like arms with 3 wheels. The 6 D.O.F of manipulator is controlled by CCD camera mounted on the elbow and base, to provide wide view of the working area for tele-operation. The off-line programming system is being developed for checking robot constraint violations within workspace prior to execution of robot programming. (Author)

  8. Human-Like Behavior of Robot Arms: General Considerations and the Handwriting Task-Part I: Mathematical Description of Human-Like Motion: Distributed Positioning and Virtual Fatigue

    NARCIS (Netherlands)

    Potkonjak, V.; Tzafestas, S.; Kostic, D.; Djordjevic, G.

    2001-01-01

    This two-part paper is concerned with the analysis and achievement of human-like behavior by robot arms (manipulators). The analysis involves three issues: (i) the resolution of the inverse kinematics problem of redundant robots, (ii) the separation of the end-effector's motion into two components,

  9. Perancangan Lengan Robot 5 Derajat Kebebasan Dengan Pendekatan Kinematika

    Directory of Open Access Journals (Sweden)

    - Firmansyah

    2014-10-01

    Full Text Available This study discusses the design of arm robot model with 5 degree of freedom that is designed to be a small-scale model of the articulated robot industry to simulate the movement of the robots industry. The objective of this research is to build a real arm robot based on kinematic aspects with the movement of waist, shoulder, elbow, wrist pitch, wrist roll and gripper, and to analyze the robot movement. The design includes building the real arm robot based on Arduino Uno board controller and the movement of the robot using servo motor DC. The robot  can be controlled automatically from the computer with the RS-232 or USB port interface and it learns about the kinematic of the robot’s arm when an experiment on the forward kinematic is accomplished. The robot was running well, with the maximum distance that can be reached by the robot on the coordinate axis  x = 425 mm, y = 425 mm and  z = 480 mm.

  10. Coordinated Resolved Motion Control of Dual-Arm Manipulators with Closed Chain

    Directory of Open Access Journals (Sweden)

    Tianliang Liu

    2016-05-01

    Full Text Available When applied to some tasks, such as payload handling, assembling, repairing and so on, the two arms of a humanoid robot will form a closed kinematic chain. It makes the motion planning and control for dual-arm coordination very complex and difficult. In this paper, we present three types of resolved motion control methods for a humanoid robot during coordinated manipulation. They are, respectively, position-level, velocity-level and acceleration-level resolved motion control methods. The desired pose, velocity and acceleration of each end-effector are then resolved according to the desired motion of the payload and the constraints on the closed-chain system without consideration of the internal force. Corresponding to the three cases above, the joint variables of each arm are then calculated using the inverse kinematic equations, at position-level, velocity-level or acceleration-level. Finally, a dynamic modelling and simulation platform is established based on ADAMS and Matlab software. The proposed methods are verified by typical cases. The simulation results show that the proposed control strategy can realize the dual-arm coordinated operation and the internal force of the closed chain during the operation is controlled in a reasonable range at the same time.

  11. Scheduling a Single Mobile Robot Incorporated into Production Environment

    DEFF Research Database (Denmark)

    Dang, Vinh Quang; Nielsen, Izabela Ewa; Steger-Jensen, Kenn

    2013-01-01

    to the challenges of issues such as energy conservation and pollution preventions. Facing the central tension between manufacturing and environmental drivers is difficult, but critical to develop new technologies, particularly mobile robots, that can be incorporated into production to achieve holistic solutions....... This chapter deals with the problem of finding optimal operating sequence in a manufacturing cell of a mobile robot with manipulation arm that feeds materials to feeders. The “Bartender Concept” is discussed to show the cooperation between the mobile robot and industrial environment. The performance criterion...

  12. Modelling cooperation of industrial robots as multi-agent systems

    Science.gov (United States)

    Hryniewicz, P.; Banas, W.; Foit, K.; Gwiazda, A.; Sekala, A.

    2017-08-01

    Nowadays, more and more often in a cell is more than one robot, there is also a dual arm robots, because of this cooperation of two robots in the same space becomes more and more important. Programming robotic cell consisting of two or more robots are currently performed separately for each element of the robot and the cell. It is performed only synchronization programs, but no robot movements. In such situations often placed industrial robots so they do not have common space so the robots are operated separately. When industrial robots are a common space this space can occupy only one robot the other one must be outside the common space. It is very difficult to find applications where two robots are in the same workspace. It was tested but one robot did not do of movement when moving the second and waited for permission to move from the second when it sent a permit - stop the move. Such programs are very difficult and require a lot of experience from the programmer and must be tested separately at the beginning and then very slowly under control. Ideally, the operator takes care of exactly one robot during the test and it is very important to take special care.

  13. Thoughts turned into high-level commands: Proof-of-concept study of a vision-guided robot arm driven by functional MRI (fMRI) signals.

    Science.gov (United States)

    Minati, Ludovico; Nigri, Anna; Rosazza, Cristina; Bruzzone, Maria Grazia

    2012-06-01

    Previous studies have demonstrated the possibility of using functional MRI to control a robot arm through a brain-machine interface by directly coupling haemodynamic activity in the sensory-motor cortex to the position of two axes. Here, we extend this work by implementing interaction at a more abstract level, whereby imagined actions deliver structured commands to a robot arm guided by a machine vision system. Rather than extracting signals from a small number of pre-selected regions, the proposed system adaptively determines at individual level how to map representative brain areas to the input nodes of a classifier network. In this initial study, a median action recognition accuracy of 90% was attained on five volunteers performing a game consisting of collecting randomly positioned coloured pawns and placing them into cups. The "pawn" and "cup" instructions were imparted through four mental imaginery tasks, linked to robot arm actions by a state machine. With the current implementation in MatLab language the median action recognition time was 24.3s and the robot execution time was 17.7s. We demonstrate the notion of combining haemodynamic brain-machine interfacing with computer vision to implement interaction at the level of high-level commands rather than individual movements, which may find application in future fMRI approaches relevant to brain-lesioned patients, and provide source code supporting further work on larger command sets and real-time processing. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. Developments of STR project in the scope of teleoperation handling robotic for the operation in Spanish nuclear facilities

    International Nuclear Information System (INIS)

    Bielza, M.; Gomez Santamaria, J.; Izquierdo, J.A.; Martinez, S.; Linares, F.; Avello, A.; Gago, M.J.

    1998-01-01

    The main objective of the Teleoperated Robotic Systems project (SRT) is the development of teleoperated robotic systems for use in the inspection, surveillance and maintenance operations in nuclear and radioactive installations. These systems make possible the reduction of the individual and collective doses of the workers that undertake these operations, as well as an increase of plant availability as it is possible to carry out specific tasks of inspection and surveillance in high radiation dose areas without having to reduce the power of the installation. This project started in 1995, deciding to priorize the inspection equipment in a first phase. When this work were advanced, the development of the manipulation activities was carried out to being consider the nuclear installations needs. As a result of this work, the manipulation requirements were elaborated in order to prepare the beginning technical specifications to design the equipment s. These developments are based on a fixed manipulator which is located closed to the equipment that we want to repair, and an arm manipulator which moves by caterpillars, it is easier to control than others; and the navigation system which allows the robot self-locating in the complex area. In this paper the conclusions about the manipulation requirements are described, as well as the state of the manipulation prototype. (Author)

  15. Timing of Multimodal Robot Behaviors during Human-Robot Collaboration

    DEFF Research Database (Denmark)

    Jensen, Lars Christian; Fischer, Kerstin; Suvei, Stefan-Daniel

    2017-01-01

    In this paper, we address issues of timing between robot behaviors in multimodal human-robot interaction. In particular, we study what effects sequential order and simultaneity of robot arm and body movement and verbal behavior have on the fluency of interactions. In a study with the Care-O-bot, ...... output plays a special role because participants carry their expectations from human verbal interaction into the interactions with robots....

  16. Modular robotics overview of the 'state of the art'

    International Nuclear Information System (INIS)

    Kress, R.L.; Jansen, J.F.; Hamel, W.R.

    1996-08-01

    The design of a robotic arm processing modular components and reconfigurable links is the general goal of a modular robotics development program. The impetus behind the pursuit of modular design is the remote engineering paradigm of improved reliability and availability provided by the ability to remotely maintain and repair a manipulator operating in a hazardous environment by removing and replacing worn or failed modules. Failed components can service off- line and away from hazardous conditions. The desire to reconfigure an arm to perform different tasks is also an important driver for the development of a modular robotic manipulator. In order to bring to fruition a truly modular manipulator, an array of technical challenges must be overcome. These range from basic mechanical and electrical design considerations such as desired kinematics, actuator types, and signal and transmission types and routings, through controls issues such as the need for control algorithms capable of stable free space and contact control, to computer and sensor design issues like consideration of the use of embedded processors and redundant sensors. This report presents a brief overview of the state of the art of technical issues relevant of modular robotic arm design. The focus is on breadth of coverage, rather than depth, in order to provide a reference frame for future development

  17. Simulation of robot manipulators

    International Nuclear Information System (INIS)

    Kress, R.L.; Babcock, S.M.; Bills, K.C.; Kwon, D.S.; Schoenwald, D.A.

    1995-01-01

    This paper describes Oak Ridge National Laboratory's development of an environment for the simulation of robotic manipulators. Simulation includes the modeling of kinematics, dynamics, sensors, actuators, control systems, operators, and environments. Models will be used for manipulator design, proposal evaluation, control system design and analysis, graphical preview of proposed motions, safety system development, and training. Of particular interest is the development of models for robotic manipulators having at least one flexible link. As a first application, models have been developed for the Pacific Northwest Laboratories' Flexible Beam Testbed which is a one-Degree-Of-Freedom, flexible arm with a hydraulic base actuator. Initial results show good agreement between model and experiment

  18. GENERAL CONSIDERATIONS OF THE EMPLOYMENT OF ROBOTS IN ARMED CONFLICTS IN THE XXI CENTURY

    Directory of Open Access Journals (Sweden)

    LUIS PÉREZ GIL

    2017-09-01

    Full Text Available This article studies the new weapon systems that can transform the notion itself of “armed conflict” in the classic sense of the term. The author deeply analyzes the differences between concepts such as robot, droid, android, UAS and UCAS, the new military hardware, and how will be the combat aircrafts of the future with systems of artificial intelligence, the field robotics, as well as the interaction between men and machines in the future combat and, finally, the revolution that the employment of this type of weapons cause in the traditional concepts of Humanitarian Law and self-defense right. The author concludes with a few reflections on the role that the newest technologies have to play necessarily in the conventional and unconventional warfare and the influence that its use will produce when these weapons will be considered “normal” in the whole world system.

  19. MODULAR MANIPULATOR FOR ROBOTICS APPLICATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Joseph W. Geisinger, Ph.D.

    2001-07-31

    ARM Automation, Inc. is developing a framework of modular actuators that can address the DOE's wide range of robotics needs. The objective of this effort is to demonstrate the effectiveness of this technology by constructing a manipulator from these actuators within a glovebox for Automated Plutonium Processing (APP). At the end of the project, the system of actuators was used to construct several different manipulator configurations, which accommodate common glovebox tasks such as repackaging. The modular nature and quickconnects of this system simplify installation into ''hot'' boxes and any potential modifications or repair therein. This work focused on the development of self-contained robotic actuator modules including the embedded electronic controls for the purpose of building a manipulator system. Both of the actuators developed under this project contain the control electronics, sensors, motor, gear train, wiring, system communications and mechanical interfaces of a complete robotics servo device. Test actuators and accompanying DISC{trademark}s underwent validation testing at The University of Texas at Austin and ARM Automation, Inc. following final design and fabrication. The system also included custom links, an umbilical cord, an open architecture PC-based system controller, and operational software that permitted integration into a completely functional robotic manipulator system. The open architecture on which this system is based avoids proprietary interfaces and communication protocols which only serve to limit the capabilities and flexibility of automation equipment. The system was integrated and tested in the contractor's facility for intended performance and operations. The manipulator was tested using the full-scale equipment and process mock-ups. The project produced a practical and operational system including a quantitative evaluation of its performance and cost.

  20. On the reproducibility of expert-operated and robotic ultrasound acquisitions.

    Science.gov (United States)

    Kojcev, Risto; Khakzar, Ashkan; Fuerst, Bernhard; Zettinig, Oliver; Fahkry, Carole; DeJong, Robert; Richmon, Jeremy; Taylor, Russell; Sinibaldi, Edoardo; Navab, Nassir

    2017-06-01

    We present the evaluation of the reproducibility of measurements performed using robotic ultrasound imaging in comparison with expert-operated sonography. Robotic imaging for interventional procedures may be a valuable contribution, but requires reproducibility for its acceptance in clinical routine. We study this by comparing repeated measurements based on robotic and expert-operated ultrasound imaging. Robotic ultrasound acquisition is performed in three steps under user guidance: First, the patient is observed using a 3D camera on the robot end effector, and the user selects the region of interest. This allows for automatic planning of the robot trajectory. Next, the robot executes a sweeping motion following the planned trajectory, during which the ultrasound images and tracking data are recorded. As the robot is compliant, deviations from the path are possible, for instance due to patient motion. Finally, the ultrasound slices are compounded to create a volume. Repeated acquisitions can be performed automatically by comparing the previous and current patient surface. After repeated image acquisitions, the measurements based on acquisitions performed by the robotic system and expert are compared. Within our case series, the expert measured the anterior-posterior, longitudinal, transversal lengths of both of the left and right thyroid lobes on each of the 4 healthy volunteers 3 times, providing 72 measurements. Subsequently, the same procedure was performed using the robotic system resulting in a cumulative total of 144 clinically relevant measurements. Our results clearly indicated that robotic ultrasound enables more repeatable measurements. A robotic ultrasound platform leads to more reproducible data, which is of crucial importance for planning and executing interventions.

  1. A crossover pilot study evaluating the functional outcomes of two different types of robotic movement training in chronic stroke survivors using the arm exoskeleton BONES.

    Science.gov (United States)

    Milot, Marie-Hélène; Spencer, Steven J; Chan, Vicky; Allington, James P; Klein, Julius; Chou, Cathy; Bobrow, James E; Cramer, Steven C; Reinkensmeyer, David J

    2013-12-19

    To date, the limited degrees of freedom (DOF) of most robotic training devices hinders them from providing functional training following stroke. We developed a 6-DOF exoskeleton ("BONES") that allows movement of the upper limb to assist in rehabilitation. The objectives of this pilot study were to evaluate the impact of training with BONES on function of the affected upper limb, and to assess whether multijoint functional robotic training would translate into greater gains in arm function than single joint robotic training also conducted with BONES. Twenty subjects with mild to moderate chronic stroke participated in this crossover study. Each subject experienced multijoint functional training and single joint training three sessions per week, for four weeks, with the order of presentation randomized. The primary outcome measure was the change in Box and Block Test (BBT). The secondary outcome measures were the changes in Fugl-Meyer Arm Motor Scale (FMA), Wolf Motor Function Test (WMFT), Motor Activity Log (MAL), and quantitative measures of strength and speed of reaching. These measures were assessed at baseline, after each training period, and at a 3-month follow-up evaluation session. Training with the robotic exoskeleton resulted in significant improvements in the BBT, FMA, WMFT, MAL, shoulder and elbow strength, and reaching speed (p robotic training programs. However, for the BBT, WMFT and MAL, inequality of carryover effects were noted; subsequent analysis on the change in score between the baseline and first period of training again revealed no difference in the gains obtained between the types of training. Training with the 6 DOF arm exoskeleton improved motor function after chronic stroke, challenging the idea that robotic therapy is only useful for impairment reduction. The pilot results presented here also suggest that multijoint functional robotic training is not decisively superior to single joint robotic training. This challenges the idea that

  2. Robot Mechanisms

    CERN Document Server

    Lenarcic, Jadran; Stanišić, Michael M

    2013-01-01

    This book provides a comprehensive introduction to the area of robot mechanisms, primarily considering industrial manipulators and humanoid arms. The book is intended for both teaching and self-study. Emphasis is given to the fundamentals of kinematic analysis and the design of robot mechanisms. The coverage of topics is untypical. The focus is on robot kinematics. The book creates a balance between theoretical and practical aspects in the development and application of robot mechanisms, and includes the latest achievements and trends in robot science and technology.

  3. Animation of Panorama of Phoenix's Solar Panel and Robotic Arm

    Science.gov (United States)

    2008-01-01

    [figure removed for brevity, see original site] Click on image for animation This is an animation of panorama images of NASA's Phoenix Mars Lander's solar panel and the lander's Robotic Arm with a sample in the scoop. The image was taken just before the sample was delivered to the Optical Microscope. The images making up this animation were taken by the lander's Surface Stereo Imager looking west during Phoenix's Sol 16 (June 10, 2008), or the 16th Martian day after landing. This view is a part of the 'mission success' panorama that will show the whole landing site in color. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  4. The use of automation and robotic systems to establish and maintain lunar base operations

    Science.gov (United States)

    Petrosky, Lyman J.

    1992-01-01

    Robotic systems provide a means of performing many of the operations required to establish and maintain a lunar base. They form a synergistic system when properly used in concert with human activities. This paper discusses the various areas where robotics and automation may be used to enhance lunar base operations. Robots are particularly well suited for surface operations (exterior to the base habitat modules) because they can be designed to operate in the extreme temperatures and vacuum conditions of the Moon (or Mars). In this environment, the capabilities of semi-autonomous robots would surpass that of humans in all but the most complex tasks. Robotic surface operations include such activities as long range geological and mineralogical surveys with sample return, materials movement in and around the base, construction of radiation barriers around habitats, transfer of materials over large distances, and construction of outposts. Most of the above operations could be performed with minor modifications to a single basic robotic rover. Within the lunar base habitats there are a few areas where robotic operations would be preferable to human operations. Such areas include routine inspections for leakage in the habitat and its systems, underground transfer of materials between habitats, and replacement of consumables. In these and many other activities, robotic systems will greatly enhance lunar base operations. The robotic systems described in this paper are based on what is realistically achievable with relatively near term technology. A lunar base can be built and maintained if we are willing.

  5. Visual and tactile interfaces for bi-directional human robot communication

    Science.gov (United States)

    Barber, Daniel; Lackey, Stephanie; Reinerman-Jones, Lauren; Hudson, Irwin

    2013-05-01

    Seamless integration of unmanned and systems and Soldiers in the operational environment requires robust communication capabilities. Multi-Modal Communication (MMC) facilitates achieving this goal due to redundancy and levels of communication superior to single mode interaction using auditory, visual, and tactile modalities. Visual signaling using arm and hand gestures is a natural method of communication between people. Visual signals standardized within the U.S. Army Field Manual and in use by Soldiers provide a foundation for developing gestures for human to robot communication. Emerging technologies using Inertial Measurement Units (IMU) enable classification of arm and hand gestures for communication with a robot without the requirement of line-of-sight needed by computer vision techniques. These devices improve the robustness of interpreting gestures in noisy environments and are capable of classifying signals relevant to operational tasks. Closing the communication loop between Soldiers and robots necessitates them having the ability to return equivalent messages. Existing visual signals from robots to humans typically require highly anthropomorphic features not present on military vehicles. Tactile displays tap into an unused modality for robot to human communication. Typically used for hands-free navigation and cueing, existing tactile display technologies are used to deliver equivalent visual signals from the U.S. Army Field Manual. This paper describes ongoing research to collaboratively develop tactile communication methods with Soldiers, measure classification accuracy of visual signal interfaces, and provides an integration example including two robotic platforms.

  6. Training the Unimpaired Arm Improves the Motion of the Impaired Arm and the Sitting Balance in Chronic Stroke Survivors.

    Science.gov (United States)

    De Luca, Alice; Giannoni, Psiche; Vernetti, Honore; Capra, Cristina; Lentino, Carmelo; Checchia, Giovanni Antonio; Casadio, Maura

    2017-07-01

    Robot-assisted rehabilitation of stroke survivors mainly focuses on the impaired side of the body while the role of the unimpaired side in the recovery after stroke is still controversial. The goal of this study is to investigate the influence on sitting balance and paretic arm functions of a training protocol based on movements of the unimpaired arm. Sixteen chronic stroke survivors underwent nineteen training sessions, in which they performed active movements with the unimpaired arm supported by a passive exoskeleton. Performance of the trunk and upper limbs was evaluated before treatment, after treatment and at six months follow up with clinical scales and an instrumented evaluation. A reaching test executed with the exoskeleton was used to assess changes in performance of both arms. The treatment based on the unimpaired arm's movements executed with a correct body posture led to benefits in control of the trunk and of both the trained and the untrained arm. The amount of impaired arm improvement in the Fugl-Meyer score was comparable to the outcome of robotic treatments focused directly on this arm. Our results highlight the importance of taking into account all body schema in the rehabilitation robotic program, instead of focusing only on the impaired side of the body.

  7. Utilizing Robot Operating System (ROS) in Robot Vision and Control

    Science.gov (United States)

    2015-09-01

    Palmer, “Development of a navigation system for semi-autonomous operation of wheelchairs,” in Proc. of the 8th IEEE/ASME Int. Conf. on Mechatronic ...and Embedded Systems and Applications, Suzhou, China, 2012, pp. 257-262. [30] G. Grisetti, C. Stachniss, and W. Burgard, “Improving grid-based SLAM...OPERATING SYSTEM (ROS) IN ROBOT VISION AND CONTROL by Joshua S. Lum September 2015 Thesis Advisor: Xiaoping Yun Co-Advisor: Zac Staples

  8. Remote Lab for Robotics Applications

    Directory of Open Access Journals (Sweden)

    Robinson Jiménez

    2018-01-01

    Full Text Available This article describes the development of a remote lab environment used to test and training sessions for robotics tasks. This environment is made up of the components and devices based on two robotic arms, a network link, Arduino card and Arduino shield for Ethernet, as well as an IP camera. The remote laboratory is implemented to perform remote control of the robotic arms with visual feedback by camera, of the robots actions, where, with a group of test users, it was possible to obtain performance ranges in tasks of telecontrol of up to 92%.

  9. Research on a Micro Flip Robot That Can Climb Stairs

    Directory of Open Access Journals (Sweden)

    Jianzhong Wang

    2016-03-01

    Full Text Available Micro mobile robots (MMRs can operate in rugged, narrow or dangerous regions; thus, they are widely used in numerous areas including surveillance, rescue and exploration. In urban environments, stairs are common obstacles, ones that such robots find difficult to manoeuvre over. The authors analysed the research status of MMRs, particularly in terms of difficulties when performing stair climbing and present a novel type of MMR called the micro flip robot (MFRobot. A support arm subassembly was added to the centre of a wheeled chassis; using this structure, the MFRobot can climb stairs when a flipping mode is utilized. Based on this structure, the authors established a kinematic model of the stair-climbing process and analysed the force conditions for the key status, contributing to the existing knowledge of robot design. An MFRobot prototype was produced and the stair-climbing experiments, as well as experiments on manoeuvring through rubble regions and slope surfaces, were conducted. The results show that the MFRobot can rapidly climb common stairs and can easily manoeuvre through a rubble region. The maximum slope angle the robot can climb was shown to be about 35° for concrete and wooden slope surfaces. In the case where the robot needed to be equipped with sensors, particularly a camera, the camera was equipped on the support arm of robot. The MFRobot prototype weighs 2.5 kg and is easily transportable. This structure can resolve contradictions between portability and performance in terms of overcoming obstacles; in addition, operational effectiveness can be improved using this structure.

  10. An emergency response mobile robot for operations in combustible atmospheres

    Science.gov (United States)

    Stone, Henry W. (Inventor); Ohm, Timothy R. (Inventor)

    1993-01-01

    A mobile, self-powered, self-contained, and remote-controlled robot is presented. The robot is capable of safely operating in a combustible atmosphere and providing information about the atmosphere to the operator. The robot includes non-sparking and non-arcing electro-mechanical and electronic components designed to prevent the robot from igniting the combustible atmosphere. The robot also includes positively pressurized enclosures that house the electromechanical and electronic components of the robot and prevent intrusion of the combustible atmosphere into the enclosures. The enclosures are interconnected such that a pressurized gas injected into any one of the enclosures is routed to all the other enclosures through the interconnections. It is preferred that one or more sealed internal channels through structures intervening between the enclosures be employed. Pressure transducers for detecting if the pressure within the enclosures falls below a predetermined level are included. The robot also has a sensing device for determining the types of combustible substances in the surrounding atmosphere, as well as the concentrations of each type of substance relative to a pre-determined lower explosive limit (LEL). In addition, the sensing device can determine the percent level of oxygen present in the surrounding atmosphere.

  11. Robot off-line programming and simulation as a true CIME-subsystem

    DEFF Research Database (Denmark)

    Nielsen, L.F; Trostmann, S; Trostmann, Erik

    1992-01-01

    A robot off-line programming and real-time simulation system, ROPSIM, which is based on the neutral interface concept and features simulation of the dynamics of both the controller and robot arm, has been developed. To avoid dependency on dedicated robot models, ROPSIM is based on generic models...... describing the robot controller, robot arm geometry, and the robot and arm kinetics. The software was developed using the C++ programming language. The key modules are discussed. The system is a true computer-integrated manufacturing and engineering subsystem which facilitates the exchange and reuse of robot...... model definition data and robot program definition data with systems of other origin or different functionality...

  12. Device for dynamic switching of robot control points

    DEFF Research Database (Denmark)

    2015-01-01

    The invention comprises a system for switching between control points of a robotic system involving an industrial robot including a robot arm with a number of joints and provided with a tool interest point movable in a plurality of degrees of freedom.......The invention comprises a system for switching between control points of a robotic system involving an industrial robot including a robot arm with a number of joints and provided with a tool interest point movable in a plurality of degrees of freedom....

  13. Robotics in hostile environment I. S. I. S. robot - automatic positioning and docking with proximity and force feed back sensors

    Energy Technology Data Exchange (ETDEWEB)

    Gery, D

    1987-01-01

    Recent improvements in control command systems and the development of tactile proximity and force feed back sensors make it possible to robotize complex inspection and maintenance operations in hostile environment, which could have not been possible by classical remotely operated manipulators. We describe the I.S.I.S. robot characteristics, the control command system software principles and the tactile and force-torque sensors which have been developed for the different sequences of an hostile environment inspection and repair: access trajectories generation with obstacles shunning, final positioning and docking using parametric algorithms taking into account measurement of the end of arm proximity and force-torque sensors.

  14. A comparison of robotic arm versus gantry linear accelerator stereotactic body radiation therapy for prostate cancer.

    Science.gov (United States)

    Avkshtol, Vladimir; Dong, Yanqun; Hayes, Shelly B; Hallman, Mark A; Price, Robert A; Sobczak, Mark L; Horwitz, Eric M; Zaorsky, Nicholas G

    2016-01-01

    Prostate cancer is the most prevalent cancer diagnosed in men in the United States besides skin cancer. Stereotactic body radiation therapy (SBRT; 6-15 Gy per fraction, up to 45 minutes per fraction, delivered in five fractions or less, over the course of approximately 2 weeks) is emerging as a popular treatment option for prostate cancer. The American Society for Radiation Oncology now recognizes SBRT for select low- and intermediate-risk prostate cancer patients. SBRT grew from the notion that high doses of radiation typical of brachytherapy could be delivered noninvasively using modern external-beam radiation therapy planning and delivery methods. SBRT is most commonly delivered using either a traditional gantry-mounted linear accelerator or a robotic arm-mounted linear accelerator. In this systematic review article, we compare and contrast the current clinical evidence supporting a gantry vs robotic arm SBRT for prostate cancer. The data for SBRT show encouraging and comparable results in terms of freedom from biochemical failure (>90% for low and intermediate risk at 5-7 years) and acute and late toxicity (6 MV). Finally, SBRT (particularly on a gantry) may also be more cost-effective than conventionally fractionated external-beam radiation therapy. Randomized controlled trials of SBRT using both technologies are underway.

  15. Robot vision for nuclear advanced robot

    International Nuclear Information System (INIS)

    Nakayama, Ryoichi; Okano, Hideharu; Kuno, Yoshinori; Miyazawa, Tatsuo; Shimada, Hideo; Okada, Satoshi; Kawamura, Astuo

    1991-01-01

    This paper describes Robot Vision and Operation System for Nuclear Advanced Robot. This Robot Vision consists of robot position detection, obstacle detection and object recognition. With these vision techniques, a mobile robot can make a path and move autonomously along the planned path. The authors implemented the above robot vision system on the 'Advanced Robot for Nuclear Power Plant' and tested in an environment mocked up as nuclear power plant facilities. Since the operation system for this robot consists of operator's console and a large stereo monitor, this system can be easily operated by one person. Experimental tests were made using the Advanced Robot (nuclear robot). Results indicate that the proposed operation system is very useful, and can be operate by only person. (author)

  16. Improvement of the operation of wheels mobile robot TRASMAR2; Mejora del funcionamiento del robot movil de ruedas TRASMAR2

    Energy Technology Data Exchange (ETDEWEB)

    Guerra C, D. A.; Tovar M, R. [Instituto Tecnologico de San Luis Potosi, Av. Tecnologico s/n, Col. UPA Soledad de Graciano Sanchez, 78437 San Luis Potosi (Mexico); Gonzalez M, J. L.; Segovia de los Rios, A., E-mail: deniwar@gmail.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2013-10-15

    In the Instituto Nacional de Investigaciones Nucleares (ININ), personnel have been working in the development of wheels mobile robots for the surveillance and supervision of contaminated areas, and for the radioactive material transport. One of these achievements is the wheels mobile robot denominated TRASMAR2, which is sought that works in the tele operated form using net technologies, in particular, using a Web page by means of the client-servant technology. For this, diverse circuits and control programs have been development with the purpose that the robot carries out the movements that are required, being considered the use of sensors to avoid collisions. The different programs have been implemented in different micro controllers, and although the robot was working, is necessary to optimize and to concentrate these programs on a single micro controller. In this work are presented the analysis of the previously implemented programs, as the realized changes, including new programs required to improve the robot operation. As complement, was development and implemented an alternative proposal of the robot's tele operation by means of a Web page using Lab view, which is described in the work. With this proposal tele operate the robot was achieved, although its application is evaluating due to the resources that is consumes. (author)

  17. Controller design for Robotic hand through Electroencephalogram

    OpenAIRE

    Pandelidis P.; Kiriazis N.; Orgianelis K.; Koulios N.

    2016-01-01

    - This paper deals with the designing, the construction and the control of a robotic hand via an electroencephalogram sensor. First a robotic device that is able to mimic a real human hand is constructed. A PID controller is designed in order to improve the performance of the robotic arm for grabbing objects. Furthermore, a novel design approach is presented for controlling the motion of the robotic arm using signals produced from an innovative electroencephalogram sensor that detects the con...

  18. Toward humanoid robots for operations in complex urban environments

    Science.gov (United States)

    Pratt, Jerry E.; Neuhaus, Peter; Johnson, Matthew; Carff, John; Krupp, Ben

    2010-04-01

    Many infantry operations in urban environments, such as building clearing, are extremely dangerous and difficult and often result in high casualty rates. Despite the fast pace of technological progress in many other areas, the tactics and technology deployed for many of these dangerous urban operation have not changed much in the last 50 years. While robots have been extremely useful for improvised explosive device (IED) detonation, under-vehicle inspection, surveillance, and cave exploration, there is still no fieldable robot that can operate effectively in cluttered streets and inside buildings. Developing a fieldable robot that can maneuver in complex urban environments is challenging due to narrow corridors, stairs, rubble, doors and cluttered doorways, and other obstacles. Typical wheeled and tracked robots have trouble getting through most of these obstacles. A bipedal humanoid is ideally shaped for many of these obstacles because its legs are long and skinny. Therefore it has the potential to step over large barriers, gaps, rocks, and steps, yet squeeze through narrow passageways, and through narrow doorways. By being able to walk with one foot directly in front of the other, humanoids also have the potential to walk over narrow "balance beam" style objects and can cross a narrow row of stepping stones. We describe some recent advances in humanoid robots, particularly recovery from disturbances, such as pushes and walking over rough terrain. Our disturbance recovery algorithms are based on the concept of Capture Points. An N-Step Capture Point is a point on the ground in which a legged robot can step to in order to stop in N steps. The N-Step Capture Region is the set of all N-Step Capture Points. In order to walk without falling, a legged robot must step somewhere in the intersection between an N-Step Capture Region and the available footholds on the ground. We present results of push recovery using Capture Points on our humanoid robot M2V2.

  19. Intelligent control of robotic arm/hand systems for the NASA EVA retriever using neural networks

    Science.gov (United States)

    Mclauchlan, Robert A.

    1989-01-01

    Adaptive/general learning algorithms using varying neural network models are considered for the intelligent control of robotic arm plus dextrous hand/manipulator systems. Results are summarized and discussed for the use of the Barto/Sutton/Anderson neuronlike, unsupervised learning controller as applied to the stabilization of an inverted pendulum on a cart system. Recommendations are made for the application of the controller and a kinematic analysis for trajectory planning to simple object retrieval (chase/approach and capture/grasp) scenarios in two dimensions.

  20. A novel approach to haptic tele-operation of aerial robot vehicles

    NARCIS (Netherlands)

    Stramigioli, Stefano; Mahony, Robert; Corke, Peter

    2010-01-01

    We present a novel, simple and effective approach for tele-operation of aerial robotic vehicles with haptic feedback. Such feedback provides the remote pilot with an intuitive feel of the robot's state and perceived local environment that will ensure simple and safe operation in cluttered 3D

  1. INTEGRATED ROBOT-HUMAN CONTROL IN MINING OPERATIONS

    Energy Technology Data Exchange (ETDEWEB)

    George Danko

    2005-04-01

    This report contains a detailed description of the work conducted in the first year of the project on Integrated Robot-Human Control in Mining Operations at University of Nevada, Reno. This project combines human operator control with robotic control concepts to create a hybrid control architecture, in which the strengths of each control method are combined to increase machine efficiency and reduce operator fatigue. The kinematics reconfiguration type differential control of the excavator implemented with a variety of ''software machine kinematics'' is the key feature of the project. This software re-configured excavator is more desirable to execute a given digging task. The human operator retains the master control of the main motion parameters, while the computer coordinates the repetitive movement patterns of the machine links. These repetitive movements may be selected from a pre-defined family of trajectories with different transformations. The operator can make adjustments to this pattern in real time, as needed, to accommodate rapidly-changing environmental conditions. A Bobcat{reg_sign} 435 excavator was retrofitted with electro-hydraulic control valve elements. The modular electronic control was tested and the basic valve characteristics were measured for each valve at the Robotics Laboratory at UNR. Position sensors were added to the individual joint control actuators, and the sensors were calibrated. An electronic central control system consisting of a portable computer, converters and electronic driver components was interfaced to the electro-hydraulic valves and position sensors. The machine is operational with or without the computer control system depending on whether the computer interface is on or off. In preparation for emulated mining tasks tests, typical, repetitive tool trajectories during surface mining operations were recorded at the Newmont Mining Corporation's ''Lone Tree'' mine in Nevada.

  2. Pneumatic-type surgical robot end-effector for laparoscopic surgical-operation-by-wire.

    Science.gov (United States)

    Lee, Chiwon; Park, Woo Jung; Kim, Myungjoon; Noh, Seungwoo; Yoon, Chiyul; Lee, Choonghee; Kim, Youdan; Kim, Hyeon Hoe; Kim, Hee Chan; Kim, Sungwan

    2014-09-05

    Although minimally invasive surgery (MIS) affords several advantages compared to conventional open surgery, robotic MIS systems still have many limitations. One of the limitations is the non-uniform gripping force due to mechanical strings of the existing systems. To overcome this limitation, a surgical instrument with a pneumatic gripping system consisting of a compressor, catheter balloon, micro motor, and other parts is developed. This study aims to implement a surgical instrument with a pneumatic gripping system and pitching/yawing joints using micro motors and without mechanical strings based on the surgical-operation-by-wire (SOBW) concept. A 6-axis external arm for increasing degrees of freedom (DOFs) is integrated with the surgical instrument using LabVIEW® for laparoscopic procedures. The gripping force is measured over a wide range of pressures and compared with the simulated ideal step function. Furthermore, a kinematic analysis is conducted. To validate and evaluate the system's clinical applicability, a simple peg task experiment and workspace identification experiment are performed with five novice volunteers using the fundamentals of laparoscopic surgery (FLS) board kit. The master interface of the proposed system employs the hands-on-throttle-and-stick (HOTAS) controller used in aerospace engineering. To develop an improved HOTAS (iHOTAS) controller, 6-axis force/torque sensor was integrated in the special housing. The mean gripping force (after 1,000 repetitions) at a pressure of 0.3 MPa was measured to be 5.8 N. The reaction time was found to be 0.4 s, which is almost real-time. All novice volunteers could complete the simple peg task within a mean time of 176 s, and none of them exceeded the 300 s cut-off time. The system's workspace was calculated to be 11,157.0 cm3. The proposed pneumatic gripping system provides a force consistent with that of other robotic MIS systems. It provides near real-time control. It is more durable than the

  3. The Use of Industrial Robot Arms for High Precision Patient Positioning

    International Nuclear Information System (INIS)

    Katuin, J.E.; Schreuder, A.N.; Starks, W.M.; Doskow, J.

    2003-01-01

    The Indiana University Cyclotron Facility (IUCF) is in the process of designing and building the Midwest Proton Radiation Institute (MPRI) [1]. The design process includes the development of several patient treatment systems. This paper discusses the use of two such systems that provide for the high precision positioning of a patient. They are the Patient Positioner System and the X-ray system. The Patient Positioner System positions an immobilized patient on a support device to a treatment position based on a prescribed Treatment Plan. The X-ray system uses an industrial robot arm to position a Digital Radiography Panel to acquire an X-ray image to verify the location of the prescribed treatment volume in a patient by comparing the acquired images with reference images obtained from the patient's Treatment plan

  4. Evaluation of modular robot system for maintenance tasks in hot cell

    Energy Technology Data Exchange (ETDEWEB)

    Pagala, Prithvi Sekhar, E-mail: ps.pagala@upm.es [Centre for Automation and Robotics UPM-CSIC (Spain); Ferre, Manuel, E-mail: m.ferre@upm.es [Centre for Automation and Robotics UPM-CSIC (Spain); Orona, Luis, E-mail: l.orona@gsi.de [GSI Helmholtzzentrum für Schwerionenforschung (Germany)

    2014-10-15

    Highlights: •Modular robot deployment inside hot cell for remote manipulation evaluated. •Flexible and adaptable system for variety of tasks presented. •Uses in large workspaces and evolving requirements shown. -- Abstract: This work assesses the use of a modular robot system to perform maintenance and inspection tasks such as, remote flexible inspection, manipulation and cooperation with deployed systems inside the hot cell. A flexible modular solution for the inclusion in maintenance operations is presented. The proposed heterogeneous modular robotic system is evaluated using simulations of the prototype across selected robot configuration to perform tasks. Results obtained show the advantages and ability of the modular robot to perform the necessary tasks as well as its ability to adapt and evolve depending on the need. The simulation test case inside hot cell shows modular robot configuration, a two modular arm to perform tele-operation tasks in the workspace and a wheeled platform for inspection collaborating to perform tasks. The advantage of using re-configurable modular robot over conventional robot platforms is shown.

  5. A new hybrid machine design for a 6 DOF industrial robot arm

    CSIR Research Space (South Africa)

    Shaik, AA

    2012-05-01

    Full Text Available of units sold since 1960 amounted to more than 2 230 000, and the IFR (International Federation of Robotics) estimates the total number of operational industrial robots worldwide to be between 1 021 000 and 1 300 000 units at the end of 2009. [Exec sum... productivity to be competitive on the global market and the competition for market share in rising consumer markets. [IFR 1] The main drivers for the strong recovery in 2010 were automotive manufacturers and the electronics industry. In addition...

  6. A novel robotic platform for single-port abdominal surgery

    Science.gov (United States)

    Singh, Satwinder; Cheung, Jo L. K.; Sreedhar, Biji; Hoa, Xuyen Dai; Ng, Hoi Pang; Yeung, Chung Kwong

    2018-03-01

    In this paper, a novel robot-assisted platform for single-port minimally invasive surgery is presented. A miniaturized seven degrees of freedom (dof) fully internalized in-vivo actuated robotic arm is designed. Due to in-vivo actuation, the system has a smaller footprint and can generate 20 N of gripping force. The complete work envelop of the robotic arms is 252 mm × 192 mm × 322 m. With the assistance of the cannula-swivel system, the robotic arms can also be re-positioned and have multi-quadrant reachability without any additional incision. Surgical tasks, such as lifting, gripping suturing and knot tying that are commonly used in a standard surgical procedure, were performed to verify the dexterity of the robotic arms. A single-port trans-abdominal cholecystectomy in a porcine model was successfully performed to further validate its functionality.

  7. A cognitive operating system (COGNOSYS) for JPL's robot, phase 1 report

    Science.gov (United States)

    Mathur, F. P.

    1972-01-01

    The most important software requirement for any robot development is the COGNitive Operating SYStem (COGNOSYS). This report describes the Stanford University Artificial Intelligence Laboratory's hand eye software system from the point of view of developing a cognitive operating system for JPL's robot. In this, the Phase 1 of the JPL robot COGNOSYS task the installation of a SAIL compiler and a FAIL assembler on Caltech's PDP-10 have been accomplished and guidelines have been prepared for the implementation of a Stanford University type hand eye software system on JPL-Caltech's computing facility. The alternatives offered by using RAND-USC's PDP-10 Tenex operating sytem are also considered.

  8. Ultrasonic decontamination robot

    International Nuclear Information System (INIS)

    Patenaude, R.S.

    1984-01-01

    An ultrasonic decontamination robot removes radioactive contamination from the internal surface of the inlet and outlet headers, divider plate, tube sheet, and lower portions of tubes of a nuclear power plant steam generator. A programmable microprocessor controller guides the movement of a robotic arm mounted in the header manway. An ultrasonic transducer having a solvent delivery subsystem through which ultrasonic action is achieved is moved by the arm over the surfaces. A solvent recovery suction tube is positioned within the header to remove solvent therefrom while avoiding interference with the main robotic arm. The solvent composition, temperature, pressure, viscosity, and purity are controlled to optimize the ultrasonic scrubbing action. The ultrasonic transducer is controlled at a power density, frequency, and on-off mode cycle such as to optimize scrubbing action within the range of transducer-to-surface distance and solvent layer thickness selected for the particular conditions encountered. Both solvent and transducer control actions are optimized by the programmable microprocessor. (author)

  9. Robot technology in remote inspection and repair

    International Nuclear Information System (INIS)

    Lowe, D.B.

    1981-01-01

    The development of remotely controlled equipment for use in a hostile (eg radioactive) environment is reviewed. Inspection and repair work in the core vessel of a nuclear reactor is a particular example of the need for robot devices. Devices with the ability to reach out after entering the interior of the reactor and perform specified operations some distance from the entry axis are needed. It is also necessary to design with tool retrieval emergencies in mind. Should an accident or malfunction prevent withdrawal of the equipment by normal means there must be a fail-safe mechanism of collapse and withdrawal. Visual contact with the device, usually by closed circuit TV is also necessary. Recent developments are described. These include stereoscopic imaging, a flexible arm of increased reach, dexterity and strength, and a computerized robotic arm with seven degrees of freedom to be deployed by the flexible arm. Microprocessors are used to analyse information and command functions. A current solution of the need for precise positioning and tracking of a NDT head round a reactor core is illustrated. (U.K.)

  10. Development of Pneumatic Robot Hand and Construction of Master-Slave System

    Science.gov (United States)

    Tsujiuchi, Nobutaka; Koizumi, Takayuki; Nishino, Shinya; Komatsubara, Hiroyuki; Kudawara, Tatsuwo; Hirano, Masanori

    Recently, research and development has focused on robots that work in place of people. It is necessary for robots to perform the same flexible motions as people. Additionally, such robots need to incorporate high-level safety features in order not to injure people. For creation of such robots, we need to develop a robot hand that functions like a human hand. At the same time, this type of robot hand can be used as an artificial hand. Here, we present artificial muscle-type pneumatic actuators as the driving source of a robot hand that is both safe and flexible. Some development of robot hands using pneumatic actuators has already taken place. But, until now, when a pneumatic actuator is used, a big compressor is needed. So, the driving system also needs to be big; enlargement of the driving system is a major problem. Consequently, in this research, we develop a low-pressure, low-volume pneumatic actuator for driving a robot hand that works flexibly and safely on the assumption that it will be in contact with people. We develop a five-fingered robot hand with pneumatic actuators. And, we construct a master-slave system to enable the robot hand to perform the same operations as a human hand. We make a 1-link arm that has one degree of freedom using a pneumatic actuator, and construct a control system for the 1-link arm and verify its control performance.

  11. Admittance Control of a Multi-Finger Arm Based on Manipulability of Fingers

    Directory of Open Access Journals (Sweden)

    Jian Huang

    2011-09-01

    Full Text Available In the previous studies, admittance control and impedance control for a finger-arm robot using the manipulability of the finger were studied and methods of realizing the controls have been proposed. In this study, two 3-DOF fingers are attached to the end-effector of a 6-DOF arm to configure a multi-finger arm robot. Based on the previous methods, the authors have proposed an admittance control for a multi-finger arm robot using the manipulability of the fingers in this study. Algorithms of the averaging method and the mini-max method were introduced to establish a manipulability criterion of the two fingers in order to generate a cooperative movement of the arm. Comparison of the admittance controls combined with the top search method and local optimization method for the multi-finger arm robot was made and features of the control methods were also discussed. The stiffness control and damping control were experimentally evaluated to demonstrate the effectiveness of the proposed methods.

  12. Robot and Human Surface Operations on Solar System Bodies

    Science.gov (United States)

    Weisbin, C. R.; Easter, R.; Rodriguez, G.

    2001-01-01

    This paper presents a comparison of robot and human surface operations on solar system bodies. The topics include: 1) Long Range Vision of Surface Scenarios; 2) Human and Robots Complement Each Other; 3) Respective Human and Robot Strengths; 4) Need More In-Depth Quantitative Analysis; 5) Projected Study Objectives; 6) Analysis Process Summary; 7) Mission Scenarios Decompose into Primitive Tasks; 7) Features of the Projected Analysis Approach; and 8) The "Getting There Effect" is a Major Consideration. This paper is in viewgraph form.

  13. Task-driven orbit design and implementation on a robotic C-arm system for cone-beam CT

    Science.gov (United States)

    Ouadah, S.; Jacobson, M.; Stayman, J. W.; Ehtiati, T.; Weiss, C.; Siewerdsen, J. H.

    2017-03-01

    Purpose: This work applies task-driven optimization to the design of non-circular orbits that maximize imaging performance for a particular imaging task. First implementation of task-driven imaging on a clinical robotic C-arm system is demonstrated, and a framework for orbit calculation is described and evaluated. Methods: We implemented a task-driven imaging framework to optimize orbit parameters that maximize detectability index d'. This framework utilizes a specified Fourier domain task function and an analytical model for system spatial resolution and noise. Two experiments were conducted to test the framework. First, a simple task was considered consisting of frequencies lying entirely on the fz-axis (e.g., discrimination of structures oriented parallel to the central axial plane), and a "circle + arc" orbit was incorporated into the framework as a means to improve sampling of these frequencies, and thereby increase task-based detectability. The orbit was implemented on a robotic C-arm (Artis Zeego, Siemens Healthcare). A second task considered visualization of a cochlear implant simulated within a head phantom, with spatial frequency response emphasizing high-frequency content in the (fy, fz) plane of the cochlea. An optimal orbit was computed using the task-driven framework, and the resulting image was compared to that for a circular orbit. Results: For the fz-axis task, the circle + arc orbit was shown to increase d' by a factor of 1.20, with an improvement of 0.71 mm in a 3D edge-spread measurement for edges located far from the central plane and a decrease in streak artifacts compared to a circular orbit. For the cochlear implant task, the resulting orbit favored complementary views of high tilt angles in a 360° orbit, and d' was increased by a factor of 1.83. Conclusions: This work shows that a prospective definition of imaging task can be used to optimize source-detector orbit and improve imaging performance. The method was implemented for execution of

  14. Transferring human impedance regulation skills to robots

    CERN Document Server

    Ajoudani, Arash

    2016-01-01

    This book introduces novel thinking and techniques to the control of robotic manipulation. In particular, the concept of teleimpedance control as an alternative method to bilateral force-reflecting teleoperation control for robotic manipulation is introduced. In teleimpedance control, a compound reference command is sent to the slave robot including both the desired motion trajectory and impedance profile, which are then realized by the remote controller. This concept forms a basis for the development of the controllers for a robotic arm, a dual-arm setup, a synergy-driven robotic hand, and a compliant exoskeleton for improved interaction performance.

  15. Balance Maintenance in High-Speed Motion of Humanoid Robot Arm-Based on the 6D Constraints of Momentum Change Rate

    Directory of Open Access Journals (Sweden)

    Da-song Zhang

    2014-01-01

    Full Text Available Based on the 6D constraints of momentum change rate (CMCR, this paper puts forward a real-time and full balance maintenance method for the humanoid robot during high-speed movement of its 7-DOF arm. First, the total momentum formula for the robot’s two arms is given and the momentum change rate is defined by the time derivative of the total momentum. The author also illustrates the idea of full balance maintenance and analyzes the physical meaning of 6D CMCR and its fundamental relation to full balance maintenance. Moreover, discretization and optimization solution of CMCR has been provided with the motion constraint of the auxiliary arm’s joint, and the solving algorithm is optimized. The simulation results have shown the validity and generality of the proposed method on the full balance maintenance in the 6 DOFs of the robot body under 6D CMCR. This method ensures 6D dynamics balance performance and increases abundant ZMP stability margin. The resulting motion of the auxiliary arm has large abundance in joint space, and the angular velocity and the angular acceleration of these joints lie within the predefined limits. The proposed algorithm also has good real-time performance.

  16. Robotics for mixed waste operations, demonstration description

    International Nuclear Information System (INIS)

    Ward, C.R.

    1993-01-01

    The Department of Energy (DOE) Office of Technology Development (OTD) is developing technology to aid in the cleanup of DOE sites. Included in the OTD program are the Robotics Technology Development Program and the Mixed Waste Integrated Program. These two programs are working together to provide technology for the cleanup of mixed waste, which is waste that has both radioactive and hazardous constituents. There are over 240,000 cubic meters of mixed low level waste accumulated at DOE sites and the cleanup is expected to generate about 900,000 cubic meters of mixed low level waste over the next five years. This waste must be monitored during storage and then treated and disposed of in a cost effective manner acceptable to regulators and the states involved. The Robotics Technology Development Program is developing robotics technology to make these tasks safer, better, faster and cheaper through the Mixed Waste Operations team. This technology will also apply to treatment of transuranic waste. The demonstration at the Savannah River Site on November 2-4, 1993, showed the progress of this technology by DOE, universities and industry over the previous year. Robotics technology for the handling, characterization and treatment of mixed waste as well robotics technology for monitoring of stored waste was demonstrated. It was shown that robotics technology can make future waste storage and waste treatment facilities better, faster, safer and cheaper

  17. Controller design for Robotic hand through Electroencephalogram

    Directory of Open Access Journals (Sweden)

    Pandelidis P.

    2016-01-01

    Full Text Available - This paper deals with the designing, the construction and the control of a robotic hand via an electroencephalogram sensor. First a robotic device that is able to mimic a real human hand is constructed. A PID controller is designed in order to improve the performance of the robotic arm for grabbing objects. Furthermore, a novel design approach is presented for controlling the motion of the robotic arm using signals produced from an innovative electroencephalogram sensor that detects the concentration of the brain

  18. Mobile robot worksystem (Rosie). Innovative technology summary report

    International Nuclear Information System (INIS)

    1999-05-01

    The US Department of Energy (DOE) and the Federal Energy Technology Center (FETC) have developed a Large Scale Demonstration Project (LSDP) at the Chicago Pile-5 Research Reactor (CP-5) at Argonne National Laboratory-East (ANL). The objective of the LSDP is to demonstrate potentially beneficial Deactivation and Decommissioning (D and D) technologies in comparison with current baseline technologies. Rosie is a mobile robot worksystem developed for nuclear facilities D and D. Rosie performs mechanical dismantlement of radiologically contaminated structures by remotely deploying other tools or systems. At the CP-5 reactor site, Rosie is a mobile platform used to support reactor assembly demolition through its long reach, heavy lift capability and its deployment and positioning of a Kraft Predator dexterous manipulator arm. Rosie is a tethered, 50 m (165 ft) long, robotic system controlled via teleoperation from a control console that is located outside of the radiological containment area. The operator uses Rosie to move, lift or offload radioactive materials using its integral lifting hook or to position the Kraft Predator arm in locations where the arm can be used to dismantle parts of the CP-5 reactor. The specific operating areas were concentrated in two high radiation areas, one at the top of the reactor structure atop and within the reactor tank assembly and the second at a large opening on the west side of the reactor's biological shield called the west thermal column. In the first of these areas, low level radioactive waste size previously segmented or dismantled by the Dual Arm Work Platform (DAWP) and placed into a steel drum or transfer can were moved to a staging area for manual packaging. In the latter area, the manipulator arm removed and transferred shielding blocks from the west thermal column area of the reactor into waste containers. Rosie can also deploy up to twelve remotely controlled television cameras, some with microphones, which can be used

  19. RASSOR - Regolith Advanced Surface Systems Operations Robot

    Science.gov (United States)

    Gill, Tracy R.; Mueller, Rob

    2015-01-01

    The Regolith Advanced Surface Systems Operations Robot (RASSOR) is a lightweight excavator for mining in reduced gravity. RASSOR addresses the need for a lightweight (robot that is able to overcome excavation reaction forces while operating in reduced gravity environments such as the moon or Mars. A nominal mission would send RASSOR to the moon to operate for five years delivering regolith feedstock to a separate chemical plant, which extracts oxygen from the regolith using H2 reduction methods. RASSOR would make 35 trips of 20 kg loads every 24 hours. With four RASSORs operating at one time, the mission would achieve 10 tonnes of oxygen per year (8 t for rocket propellant and 2 t for life support). Accessing craters in space environments may be extremely hard and harsh due to volatile resources - survival is challenging. New technologies and methods are required. RASSOR is a product of KSC Swamp Works which establishes rapid, innovative and cost effective exploration mission solutions by leveraging partnerships across NASA, industry and academia.

  20. A cost-effective intelligent robotic system with dual-arm dexterous coordination and real-time vision

    Science.gov (United States)

    Marzwell, Neville I.; Chen, Alexander Y. K.

    1991-01-01

    articulated arms, one movable robot head, and two charged coupled device (CCD) cameras for producing the stereoscopic views, and articulated cylindrical-type lower body, and an optional mobile base. A functional prototype is demonstrated.

  1. Multimodal interaction for human-robot teams

    Science.gov (United States)

    Burke, Dustin; Schurr, Nathan; Ayers, Jeanine; Rousseau, Jeff; Fertitta, John; Carlin, Alan; Dumond, Danielle

    2013-05-01

    Unmanned ground vehicles have the potential for supporting small dismounted teams in mapping facilities, maintaining security in cleared buildings, and extending the team's reconnaissance and persistent surveillance capability. In order for such autonomous systems to integrate with the team, we must move beyond current interaction methods using heads-down teleoperation which require intensive human attention and affect the human operator's ability to maintain local situational awareness and ensure their own safety. This paper focuses on the design, development and demonstration of a multimodal interaction system that incorporates naturalistic human gestures, voice commands, and a tablet interface. By providing multiple, partially redundant interaction modes, our system degrades gracefully in complex environments and enables the human operator to robustly select the most suitable interaction method given the situational demands. For instance, the human can silently use arm and hand gestures for commanding a team of robots when it is important to maintain stealth. The tablet interface provides an overhead situational map allowing waypoint-based navigation for multiple ground robots in beyond-line-of-sight conditions. Using lightweight, wearable motion sensing hardware either worn comfortably beneath the operator's clothing or integrated within their uniform, our non-vision-based approach enables an accurate, continuous gesture recognition capability without line-of-sight constraints. To reduce the training necessary to operate the system, we designed the interactions around familiar arm and hand gestures.

  2. Intuitive adaptive orientation control of assistive robots for people living with upper limb disabilities.

    Science.gov (United States)

    Vu, Dinh-Son; Allard, Ulysse Cote; Gosselin, Clement; Routhier, Francois; Gosselin, Benoit; Campeau-Lecours, Alexandre

    2017-07-01

    Robotic assistive devices enhance the autonomy of individuals living with physical disabilities in their day-to-day life. Although the first priority for such devices is safety, they must also be intuitive and efficient from an engineering point of view in order to be adopted by a broad range of users. This is especially true for assistive robotic arms, as they are used for the complex control tasks of daily living. One challenge in the control of such assistive robots is the management of the end-effector orientation which is not always intuitive for the human operator, especially for neophytes. This paper presents a novel orientation control algorithm designed for robotic arms in the context of human-robot interaction. This work aims at making the control of the robot's orientation easier and more intuitive for the user, in particular, individuals living with upper limb disabilities. The performance and intuitiveness of the proposed orientation control algorithm is assessed through two experiments with 25 able-bodied subjects and shown to significantly improve on both aspects.

  3. Feasibility study of a hand guided robotic drill for cochleostomy.

    Science.gov (United States)

    Brett, Peter; Du, Xinli; Zoka-Assadi, Masoud; Coulson, Chris; Reid, Andrew; Proops, David

    2014-01-01

    The concept of a hand guided robotic drill has been inspired by an automated, arm supported robotic drill recently applied in clinical practice to produce cochleostomies without penetrating the endosteum ready for inserting cochlear electrodes. The smart tactile sensing scheme within the drill enables precise control of the state of interaction between tissues and tools in real-time. This paper reports development studies of the hand guided robotic drill where the same consistent outcomes, augmentation of surgeon control and skill, and similar reduction of induced disturbances on the hearing organ are achieved. The device operates with differing presentation of tissues resulting from variation in anatomy and demonstrates the ability to control or avoid penetration of tissue layers as required and to respond to intended rather than involuntary motion of the surgeon operator. The advantage of hand guided over an arm supported system is that it offers flexibility in adjusting the drilling trajectory. This can be important to initiate cutting on a hard convex tissue surface without slipping and then to proceed on the desired trajectory after cutting has commenced. The results for trials on phantoms show that drill unit compliance is an important factor in the design.

  4. Soft brain-machine interfaces for assistive robotics: A novel control approach.

    Science.gov (United States)

    Schiatti, Lucia; Tessadori, Jacopo; Barresi, Giacinto; Mattos, Leonardo S; Ajoudani, Arash

    2017-07-01

    Robotic systems offer the possibility of improving the life quality of people with severe motor disabilities, enhancing the individual's degree of independence and interaction with the external environment. In this direction, the operator's residual functions must be exploited for the control of the robot movements and the underlying dynamic interaction through intuitive and effective human-robot interfaces. Towards this end, this work aims at exploring the potential of a novel Soft Brain-Machine Interface (BMI), suitable for dynamic execution of remote manipulation tasks for a wide range of patients. The interface is composed of an eye-tracking system, for an intuitive and reliable control of a robotic arm system's trajectories, and a Brain-Computer Interface (BCI) unit, for the control of the robot Cartesian stiffness, which determines the interaction forces between the robot and environment. The latter control is achieved by estimating in real-time a unidimensional index from user's electroencephalographic (EEG) signals, which provides the probability of a neutral or active state. This estimated state is then translated into a stiffness value for the robotic arm, allowing a reliable modulation of the robot's impedance. A preliminary evaluation of this hybrid interface concept provided evidence on the effective execution of tasks with dynamic uncertainties, demonstrating the great potential of this control method in BMI applications for self-service and clinical care.

  5. A locomotive inspection robot for turbine building interior inspection in nuclear power plants

    International Nuclear Information System (INIS)

    Obama, M.; Ozaki, F.; Asano, K.

    1985-01-01

    A locomotive inspection robot, named Turbine Building Inspection System (TBIS), has been developed for turbine building interior inspections in nuclear power plants. This robot is made up of a vehicle, a telescopic support, turning head and a multijoint arm which has dual TV cameras and a diagnostic rod on its tip. The multijoint arm has 17 degrees of freedom and its length is 243 cm. Minimum and maximum heights for the multijoint arm shoulder are 1.5 meter and 4 meters respectively. The total degree of freedom in the combination of the multijoint arm, turning head and telescopic support is 19 and the area, it is capable of inspecting, is equal to the cylindrical dome whose height and diameter are 6.4 meters and 4.8 meters respectively. The design philosophy, hardware structure and operation method of the TBIS are described. 2 refs.; 10 figs

  6. Towards Autonomous Operations of the Robonaut 2 Humanoid Robotic Testbed

    Science.gov (United States)

    Badger, Julia; Nguyen, Vienny; Mehling, Joshua; Hambuchen, Kimberly; Diftler, Myron; Luna, Ryan; Baker, William; Joyce, Charles

    2016-01-01

    The Robonaut project has been conducting research in robotics technology on board the International Space Station (ISS) since 2012. Recently, the original upper body humanoid robot was upgraded by the addition of two climbing manipulators ("legs"), more capable processors, and new sensors, as shown in Figure 1. While Robonaut 2 (R2) has been working through checkout exercises on orbit following the upgrade, technology development on the ground has continued to advance. Through the Active Reduced Gravity Offload System (ARGOS), the Robonaut team has been able to develop technologies that will enable full operation of the robotic testbed on orbit using similar robots located at the Johnson Space Center. Once these technologies have been vetted in this way, they will be implemented and tested on the R2 unit on board the ISS. The goal of this work is to create a fully-featured robotics research platform on board the ISS to increase the technology readiness level of technologies that will aid in future exploration missions. Technology development has thus far followed two main paths, autonomous climbing and efficient tool manipulation. Central to both technologies has been the incorporation of a human robotic interaction paradigm that involves the visualization of sensory and pre-planned command data with models of the robot and its environment. Figure 2 shows screenshots of these interactive tools, built in rviz, that are used to develop and implement these technologies on R2. Robonaut 2 is designed to move along the handrails and seat track around the US lab inside the ISS. This is difficult for many reasons, namely the environment is cluttered and constrained, the robot has many degrees of freedom (DOF) it can utilize for climbing, and remote commanding for precision tasks such as grasping handrails is time-consuming and difficult. Because of this, it is important to develop the technologies needed to allow the robot to reach operator-specified positions as

  7. Learning robotic eye-arm-hand coordination from human demonstration: a coupled dynamical systems approach.

    Science.gov (United States)

    Lukic, Luka; Santos-Victor, José; Billard, Aude

    2014-04-01

    We investigate the role of obstacle avoidance in visually guided reaching and grasping movements. We report on a human study in which subjects performed prehensile motion with obstacle avoidance where the position of the obstacle was systematically varied across trials. These experiments suggest that reaching with obstacle avoidance is organized in a sequential manner, where the obstacle acts as an intermediary target. Furthermore, we demonstrate that the notion of workspace travelled by the hand is embedded explicitly in a forward planning scheme, which is actively involved in detecting obstacles on the way when performing reaching. We find that the gaze proactively coordinates the pattern of eye-arm motion during obstacle avoidance. This study provides also a quantitative assessment of the coupling between the eye-arm-hand motion. We show that the coupling follows regular phase dependencies and is unaltered during obstacle avoidance. These observations provide a basis for the design of a computational model. Our controller extends the coupled dynamical systems framework and provides fast and synchronous control of the eyes, the arm and the hand within a single and compact framework, mimicking similar control system found in humans. We validate our model for visuomotor control of a humanoid robot.

  8. Mobile Surveillance and Monitoring Robots

    International Nuclear Information System (INIS)

    Kimberly, Howard R.; Shipers, Larry R.

    1999-01-01

    Long-term nuclear material storage will require in-vault data verification, sensor testing, error and alarm response, inventory, and maintenance operations. System concept development efforts for a comprehensive nuclear material management system have identified the use of a small flexible mobile automation platform to perform these surveillance and maintenance operations. In order to have near-term wide-range application in the Complex, a mobile surveillance system must be small, flexible, and adaptable enough to allow retrofit into existing special nuclear material facilities. The objective of the Mobile Surveillance and Monitoring Robot project is to satisfy these needs by development of a human scale mobile robot to monitor the state of health, physical security and safety of items in storage and process; recognize and respond to alarms, threats, and off-normal operating conditions; and perform material handling and maintenance operations. The system will integrate a tool kit of onboard sensors and monitors, maintenance equipment and capability, and SNL developed non-lethal threat response technology with the intelligence to identify threats and develop and implement first response strategies for abnormal signals and alarm conditions. System versatility will be enhanced by incorporating a robot arm, vision and force sensing, robust obstacle avoidance, and appropriate monitoring and sensing equipment

  9. A flexible 3D laser scanning system using a robotic arm

    Science.gov (United States)

    Fei, Zixuan; Zhou, Xiang; Gao, Xiaofei; Zhang, Guanliang

    2017-06-01

    In this paper, we present a flexible 3D scanning system based on a MEMS scanner mounted on an industrial arm with a turntable. This system has 7-degrees of freedom and is able to conduct a full field scan from any angle, suitable for scanning object with the complex shape. The existing non-contact 3D scanning system usually uses laser scanner that projects fixed stripe mounted on the Coordinate Measuring Machine (CMM) or industrial robot. These existing systems can't perform path planning without CAD models. The 3D scanning system presented in this paper can scan the object without CAD models, and we introduced this path planning method in the paper. We also propose a practical approach to calibrating the hand-in-eye system based on binocular stereo vision and analyzes the errors of the hand-eye calibration.

  10. Design and implementation of a training strategy in chronic stroke with an arm robotic exoskeleton.

    Science.gov (United States)

    Frisoli, Antonio; Sotgiu, Edoardo; Procopio, Caterina; Bergamasco, Massimo; Rossi, Bruno; Chisari, Carmelo

    2011-01-01

    The distinguishing features of active exoskeletons are the capability of guiding arm movement at the level of the full kinematic chain of the human arm, and training full 3D spatial movements. We have specifically developed a PD sliding mode control for upper limb rehabilitation with gain scheduling for providing "assistance as needed", according to the force capability of the patient, and an automatic measurement of the impaired arm joint torques, to evaluate the hypertonia associated to the movement during the execution of the training exercise. Two different training tasks in Virtual Reality were devised, that make use of the above control, and allow to make a performance based evaluation of patient's motor status. The PERCRO L-Exos (Light-Exoskeleton) was used to evaluate the proposed algorithms and training exercises in two clinical case studies of patients with chronic stroke, that performed 6 weeks of robotic assisted training. Clinical evaluation (Fugl-Meyer Scale, Modified Ashworth Scale, Bimanual Activity Test) was conducted before and after treatment and compared to the scores and the quantitative indices, such as task time, position/joint error and resistance torques, associated to the training exercises. © 2011 IEEE

  11. Design of teleoperated robot system for nozzle dam maintenance in steam generator

    International Nuclear Information System (INIS)

    Kim, Chang-Hoi; Hwang, Suk-Young; Lee, Young-Gwang; Kim, Byung-Soo; Kim, Seung-Ho; Lee, Jong-Min

    1994-01-01

    The recent development of teleoperated manipulator system in KAERI is presented. The manipulator system is composed of master-slave arm and control system with VME based hierarchical structure. Supervisory control part with graphic workstation provides affluent visual information to human operator. This robot can be operated either in the teleoperation mode with master-slave or in the program mode running by computer system itself to enable installation or removal of nozzle dam appropriately within a water chamber of steam generator. Evaluation and analysis have been carried out to get optimal parameters of the robot. (author)

  12. ARMin III – Arm Therapy Exoskeleton with an Ergonomic Shoulder Actuation

    Directory of Open Access Journals (Sweden)

    Tobias Nef

    2009-01-01

    Full Text Available Rehabilitation robots have become important tools in stroke rehabilitation. Compared to manual arm training, robot-supported training can be more intensive, of longer duration and more repetitive. Therefore, robots have the potential to improve the rehabilitation process in stroke patients. Whereas a majority of previous work in upper limb rehabilitation robotics has focused on end-effector-based robots, a shift towards exoskeleton robots is taking place because they offer a better guidance of the human arm, especially for movements with a large range of motion. However, the implementation of an exoskeleton device introduces the challenge of reproducing the motion of the human shoulder, which is one of the most complex joints of the body. Thus, this paper starts with describing a simplified model of the human shoulder. On the basis of that model, a new ergonomic shoulder actuation principle that provides motion of the humerus head is proposed, and its implementation in the ARMin III arm therapy robot is described. The focus lies on the mechanics and actuation principle. The ARMin III robot provides three actuated degrees of freedom for the shoulder and one for the elbow joint. An additional module provides actuated lower arm pro/supination and wrist flexion/extension. Five ARMin III devices have been manufactured and they are currently undergoing clinical evaluation in hospitals in Switzerland and in the United States.

  13. Humanlike robot hands controlled by brain activity arouse illusion of ownership in operators

    Science.gov (United States)

    Alimardani, Maryam; Nishio, Shuichi; Ishiguro, Hiroshi

    2013-08-01

    Operators of a pair of robotic hands report ownership for those hands when they hold image of a grasp motion and watch the robot perform it. We present a novel body ownership illusion that is induced by merely watching and controlling robot's motions through a brain machine interface. In past studies, body ownership illusions were induced by correlation of such sensory inputs as vision, touch and proprioception. However, in the presented illusion none of the mentioned sensations are integrated except vision. Our results show that during BMI-operation of robotic hands, the interaction between motor commands and visual feedback of the intended motions is adequate to incorporate the non-body limbs into one's own body. Our discussion focuses on the role of proprioceptive information in the mechanism of agency-driven illusions. We believe that our findings will contribute to improvement of tele-presence systems in which operators incorporate BMI-operated robots into their body representations.

  14. Application Value of Slider-Crank Mechanism in Pick-and-Place Operation of Delta Robot

    Directory of Open Access Journals (Sweden)

    Zhe QIN

    2018-01-01

    Full Text Available By absorbing the advantages of the rotary-driven Delta robot and linear-driven Delta robot, a Delta robot for pick-and-place operation that forms a crank-slider at the drive joint is designed.To take the most common gate shaped curve in Cartesian space as the motion trail of robotic pick-and-place operation, according to the kinematics inverse solution theory of Delta robot, this thesis mainly solves the output angular velocity of robot-driven joint. Establishing the static transfer mathematical model and solving the forced condition of driving joint. The simulation analysis show that after the upper slider-crank mechanism is connected to the driving joint, the angular velocity of the driving joint changes suddenly, which caused a rigid impact on the robot in the picking and releasing operation, though the force of the driving joint can be made smaller.

  15. Investigation of human-robot interface performance in household environments

    Science.gov (United States)

    Cremer, Sven; Mirza, Fahad; Tuladhar, Yathartha; Alonzo, Rommel; Hingeley, Anthony; Popa, Dan O.

    2016-05-01

    Today, assistive robots are being introduced into human environments at an increasing rate. Human environments are highly cluttered and dynamic, making it difficult to foresee all necessary capabilities and pre-program all desirable future skills of the robot. One approach to increase robot performance is semi-autonomous operation, allowing users to intervene and guide the robot through difficult tasks. To this end, robots need intuitive Human-Machine Interfaces (HMIs) that support fine motion control without overwhelming the operator. In this study we evaluate the performance of several interfaces that balance autonomy and teleoperation of a mobile manipulator for accomplishing several household tasks. Our proposed HMI framework includes teleoperation devices such as a tablet, as well as physical interfaces in the form of piezoresistive pressure sensor arrays. Mobile manipulation experiments were performed with a sensorized KUKA youBot, an omnidirectional platform with a 5 degrees of freedom (DOF) arm. The pick and place tasks involved navigation and manipulation of objects in household environments. Performance metrics included time for task completion and position accuracy.

  16. Admittance Control of a Multi-Finger Arm Based on Manipulability of Fingers

    Directory of Open Access Journals (Sweden)

    Takayuki Hori

    2011-09-01

    Full Text Available In the previous studies, admittance control and impedance control for a finger‐arm robot using the manipulability of the finger were studied and methods of realizing the controls have been proposed. In this study, two 3‐DOF fingers are attached to the end‐effector of a 6‐DOF arm to configure a multi‐finger arm robot. Based on the previous methods, the authors have proposed an admittance control for a multi‐finger arm robot using the manipulability of the fingers in this study. Algorithms of the averaging method and the mini‐max method were introduced to establish a manipulability criterion of the two fingers in order to generate a cooperative movement of the arm. Comparison of the admittance controls combined with the top search method and local optimization method for the multi‐finger arm robot was made and features of the control methods were also discussed. The stiffness control and damping control were experimentally evaluated to demonstrate the effectiveness of the proposed methods.

  17. Robotic autopositioning of the operating microscope.

    Science.gov (United States)

    Oppenlander, Mark E; Chowdhry, Shakeel A; Merkl, Brandon; Hattendorf, Guido M; Nakaji, Peter; Spetzler, Robert F

    2014-06-01

    Use of the operating microscope has become pervasive since its introduction to the neurosurgical world. Neuronavigation fused with the operating microscope has allowed accurate correlation of the focal point of the microscope and its location on the downloaded imaging study. However, the robotic ability of the Pentero microscope has not been utilized to orient the angle of the microscope or to change its focal length to hone in on a predefined target. To report a novel technology that allows automatic positioning of the operating microscope onto a set target and utilization of a planned trajectory, either determined with the StealthStation S7 by using preoperative imaging or intraoperatively with the microscope. By utilizing the current motorized capabilities of the Zeiss OPMI Pentero microscope, a robotic autopositioning feature was developed in collaboration with Surgical Technologies, Medtronic, Inc. (StealthStation S7). The system is currently being tested at the Barrow Neurological Institute. Three options were developed for automatically positioning the microscope: AutoLock Current Point, Align Parallel to Plan, and Point to Plan Target. These options allow the microscope to pivot around the lesion, hover in a set plane parallel to the determined trajectory, or rotate and point to a set target point, respectively. Integration of automatic microscope positioning into the operative workflow has potential to increase operative efficacy and safety. This technology is best suited for precise trajectories and entry points into deep-seated lesions.

  18. Research on the inspection robot for cable tunnel

    Science.gov (United States)

    Xin, Shihao

    2017-03-01

    Robot by mechanical obstacle, double end communication, remote control and monitoring software components. The mechanical obstacle part mainly uses the tracked mobile robot mechanism, in order to facilitate the design and installation of the robot, the other auxiliary swing arm; double side communication part used a combination of communication wire communication with wireless communication, great improve the communication range of the robot. When the robot is controlled by far detection range, using wired communication control, on the other hand, using wireless communication; remote control part mainly completes the inspection robot walking, navigation, positioning and identification of cloud platform control. In order to improve the reliability of its operation, the preliminary selection of IPC as the control core the movable body selection program hierarchical structure as a design basis; monitoring software part is the core part of the robot, which has a definite diagnosis Can be instead of manual simple fault judgment, instead the robot as a remote actuators, staff as long as the remote control can be, do not have to body at the scene. Four parts are independent of each other but are related to each other, the realization of the structure of independence and coherence, easy maintenance and coordination work. Robot with real-time positioning function and remote control function, greatly improves the IT operation. Robot remote monitor, to avoid the direct contact with the staff and line, thereby reducing the accident casualties, for the safety of the inspection work has far-reaching significance.

  19. Development of a remote inspection robot for high pressure structures

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae C.; Kim, Jae H.; Choi, Yu R.; Moon, Soon S

    1999-10-01

    The high pressure structures in industrial plants must be periodically inspected for ensure their safety. Currently, the examination of them is manually performed by human inspectors, and there are many restrictions to examine the large containers which enclose dangerous chemicals or radioactive materials. We developed a remotely operated robot to examine these structures using recent mobile robot and computer technologies. Our robot has two magnetic caterpillars that make the robot can adhere to the structures made of steel like materials. The robot moves to the position for examination, and scans that position using ultrasonic probes equipped on it's arm, and transmits the result to the inspector according to his/her commands. Without building any auxiliary structures the robot can inspect the places where manual inspection can't reach. Therefore the robot can make shortening the inspection time as well as preventing the inspector from an accident. (author)

  20. Development of a remote inspection robot for high pressure structures

    International Nuclear Information System (INIS)

    Lee, Jae C.; Kim, Jae H.; Choi, Yu R.; Moon, Soon S.

    1999-10-01

    The high pressure structures in industrial plants must be periodically inspected for ensure their safety. Currently, the examination of them is manually performed by human inspectors, and there are many restrictions to examine the large containers which enclose dangerous chemicals or radioactive materials. We developed a remotely operated robot to examine these structures using recent mobile robot and computer technologies. Our robot has two magnetic caterpillars that make the robot can adhere to the structures made of steel like materials. The robot moves to the position for examination, and scans that position using ultrasonic probes equipped on it's arm, and transmits the result to the inspector according to his/her commands. Without building any auxiliary structures the robot can inspect the places where manual inspection can't reach. Therefore the robot can make shortening the inspection time as well as preventing the inspector from an accident. (author)

  1. Robotic bariatric surgery: a systematic review.

    Science.gov (United States)

    Fourman, Matthew M; Saber, Alan A

    2012-01-01

    Obesity is a nationwide epidemic, and the only evidence-based, durable treatment of this disease is bariatric surgery. This field has evolved drastically during the past decade. One of the latest advances has been the increased use of robotics within this field. The goal of our study was to perform a systematic review of the recent data to determine the safety and efficacy of robotic bariatric surgery. The setting was the University Hospitals Case Medical Center (Cleveland, OH). A PubMed search was performed for robotic bariatric surgery from 2005 to 2011. The inclusion criteria were English language, original research, human, and bariatric surgical procedures. Perioperative data were then collected from each study and recorded. A total of 18 studies were included in our review. The results of our systematic review showed that bariatric surgery, when performed with the use of robotics, had similar or lower complication rates compared with traditional laparoscopy. Two studies showed shorter operative times using the robot for Roux-en-Y gastric bypass, but 4 studies showed longer operative times in the robotic arm. In addition, the learning curve appears to be shorter when robotic gastric bypass is compared with the traditional laparoscopic approach. Most investigators agreed that robotic laparoscopic surgery provides superior imaging and freedom of movement compared with traditional laparoscopy. The application of robotics appears to be a safe option within the realm of bariatric surgery. Prospective randomized trials comparing robotic and laparoscopic outcomes are needed to further define the role of robotics within the field of bariatric surgery. Longer follow-up times would also help elucidate any long-term outcomes differences with the use of robotics versus traditional laparoscopy. Copyright © 2012 American Society for Metabolic and Bariatric Surgery. All rights reserved.

  2. Kinematic rate control of simulated robot hand at or near wrist singularity

    Science.gov (United States)

    Barker, K.; Houck, J. A.; Carzoo, S. W.

    1985-01-01

    A robot hand should obey movement commands from an operator on a computer program as closely as possible. However, when two of the three rotational axes of the robot wrist are colinear, the wrist loses a degree of freedom, and the usual resolved rate equations (used to move the hand in response to an operator's inputs) are indeterminant. Furthermore, rate limiting occurs in close vicinity to this singularity. An analysis shows that rate limiting occurs not only in the vicinity of this singularity but also substantially away from it, even when the operator commands rotational rates of the robot hand that are only a small percentage of the operational joint rate limits. Therefore, joint angle rates are scaled when they exceed operational limits in a real time simulation of a robot arm. Simulation results show that a small dead band avoids the wrist singularity in the resolved rate equations but can introduce a high frequency oscillation close to the singularity. However, when a coordinated wrist movement is used in conjunction with the resolved rate equations, the high frequency oscillation disappears.

  3. UN-mandated maritime arms embargo operations in Operation Unified Protector

    NARCIS (Netherlands)

    Fink, M.D.

    2011-01-01

    On the basis of UNSC Resolutions 1970 and 1973 on the situation in Libya, between March and October 2011 NATO conducted the Operation Unified Protector (OUP). An important part of this NATO-led mission was that of enforcing a UN-mandated arms embargo at sea. In this context, this article examines

  4. Humans and Robots. Educational Brief.

    Science.gov (United States)

    National Aeronautics and Space Administration, Washington, DC.

    This brief discusses human movement and robotic human movement simulators. The activity for students in grades 5-12 provides a history of robotic movement and includes making an End Effector for the robotic arms used on the Space Shuttle and the International Space Station (ISS). (MVL)

  5. Robots in P.W.R. nuclear powerplants

    International Nuclear Information System (INIS)

    Dubourg, M.

    1987-01-01

    The satisfactory operation of 37 900-MWe PWR powerplants in France, Belgium and South-Africa and the start-up of 1300 MWe powerplants allowed the development of a wide range of automatic units and robots for the periodic maintenance of nuclear plants, reducing the risk of ionizing radiation for the personnel. A large number of automated tools have been built. Among them: - inspection and maintenance systems for the tube bundle of steam generators, - robotized arms ROTETA and ROMEO for the heavy maintenance and delicate operations such as tube extraction or shot peening of tubes to improve their resistance to corrosion; - the versatile manipulator T.A.M. with electrically controlled articulations. The development of functionally versatile tools and robots and the integration of new technologies such as 3-D vision allowed the construction of the self-guided vehicle FRASTAR capable of moving within a nuclear building and in a cluttered environment. This vehicle includes means for avoiding isolated obstacles and can move on stairs [fr

  6. Hand/Eye Coordination For Fine Robotic Motion

    Science.gov (United States)

    Lokshin, Anatole M.

    1992-01-01

    Fine motions of robotic manipulator controlled with help of visual feedback by new method reducing position errors by order of magnitude. Robotic vision subsystem includes five cameras: three stationary ones providing wide-angle views of workspace and two mounted on wrist of auxiliary robot arm. Stereoscopic cameras on arm give close-up views of object and end effector. Cameras measure errors between commanded and actual positions and/or provide data for mapping between visual and manipulator-joint-angle coordinates.

  7. Integrated multi-sensory control of space robot hand

    Science.gov (United States)

    Bejczy, A. K.; Kan, E. P.; Killion, R. R.

    1985-01-01

    Dexterous manipulation of a robot hand requires the use of multiple sensors integrated into the mechanical hand under distributed microcomputer control. Where space applications such as construction, assembly, servicing and repair tasks are desired of smart robot arms and robot hands, several critical drives influence the design, engineering and integration of such an electromechanical hand. This paper describes a smart robot hand developed at the Jet Propulsion Laboratory for experimental use and evaluation with the Protoflight Manipulator Arm (PFMA) at the Marshall Space Flight Center (MSFC).

  8. Sensory-Feedback Exoskeletal Arm Controller

    Science.gov (United States)

    An, Bin; Massie, Thomas H.; Vayner, Vladimir

    2004-01-01

    An electromechanical exoskeletal arm apparatus has been designed for use in controlling a remote robotic manipulator arm. The apparatus, called a force-feedback exoskeleton arm master (F-EAM) is comfortable to wear and easy to don and doff. It provides control signals from the wearer s arm to a robot arm or a computer simulator (e.g., a virtual-reality system); it also provides force and torque feedback from sensors on the robot arm or from the computer simulator to the wearer s arm. The F-EAM enables the wearer to make the robot arm gently touch objects and finely manipulate them without exerting excessive forces. The F-EAM features a lightweight design in which the motors and gear heads that generate force and torque feedback are made smaller than they ordinarily would be: this is achieved by driving the motors to power levels greater than would ordinarily be used in order to obtain higher torques, and by providing active liquid cooling of the motors to prevent overheating at the high drive levels. The F-EAM (see figure) includes an assembly that resembles a backpack and is worn like a backpack, plus an exoskeletal arm mechanism. The FEAM has five degrees of freedom (DOFs) that correspond to those of the human arm: 1. The first DOF is that of the side-to-side rotation of the upper arm about the shoulder (rotation about axis 1). The reflected torque for this DOF is provided by motor 1 via drum 1 and a planar four-bar linkage. 2. The second DOF is that of the up-and-down rotation of the arm about the shoulder. The reflected torque for this DOF is provided by motor 2 via drum 2. 3. The third DOF is that of twisting of the upper arm about its longitudinal axis. This DOF is implemented in a cable remote-center mechanism (CRCM). The reflected torque for this DOF is provided by motor 3, which drives the upper-arm cuff and the mechanism below it. A bladder inflatable by gas or liquid is placed between the cuff and the wearer s upper arm to compensate for misalignment

  9. System for exchanging tools and end effectors on a robot

    International Nuclear Information System (INIS)

    Burry, D.B.; Williams, P.M.

    1991-01-01

    A system and method for exchanging tools and end effectors on a robot permits exchange during a programmed task. The exchange mechanism is located off the robot, thus reducing the mass of the robot arm and permitting smaller robots to perform designated tasks. A simple spring/collet mechanism mounted on the robot is used which permits the engagement and disengagement of the tool or end effector without the need for a rotational orientation of the tool to the end effector/collet interface. As the tool changing system is not located on the robot arm no umbilical cords are located on robot. 12 figures

  10. Hand-Arm vibration assessment among tiller operator

    Directory of Open Access Journals (Sweden)

    P. Nassiri

    2013-08-01

    Result: Results of the present study indicated that in all measured situations, exposure to hand arm vibration was higher than the standard limit suggested by Iranian occupational health committee and there was risk of vibration-induced disorders. The maximum exposure to vibration is in plowing ground. Exposure to hand arm vibration in three modes of plowing, transmission and natural, were respectively 16.95, 14.16 and 8.65 meters per second squared. Additionally, in all situations, vibration exposure was highest in the X-axis in comparison with Z- and Y-axes. .Conclusion: This study emphasizes on the need to provide intervention and controlling and managing strategies in order to eliminate or reduce vibration transmitted from tiller to operators hand and arm and also prevent to serious problems including neurovascular disorders, discomfort and white finger syndrome. Meanwhile, more studies are necessary to identify the sources of vibration on different models of tiller.

  11. Modeling and identification for high-performance robot control : an RRR-robotic arm case study

    NARCIS (Netherlands)

    Kostic, D.; Jager, de A.G.; Steinbuch, M.; Hensen, R.H.A.

    2004-01-01

    We explain a procedure for getting models of robot kinematics and dynamics that are appropriate for robot control design. The procedure consists of the following steps: (i) derivation of robot kinematic and dynamic models and establishing correctness of their structures; (ii) experimental estimation

  12. Disposable Fluidic Actuators for Miniature In-Vivo Surgical Robotics.

    Science.gov (United States)

    Pourghodrat, Abolfazl; Nelson, Carl A

    2017-03-01

    Fusion of robotics and minimally invasive surgery (MIS) has created new opportunities to develop diagnostic and therapeutic tools. Surgical robotics is advancing from externally actuated systems to miniature in-vivo robotics. However, with miniaturization of electric-motor-driven surgical robots, there comes a trade-off between the size of the robot and its capability. Slow actuation, low load capacity, sterilization difficulties, leaking electricity and transferring produced heat to tissues, and high cost are among the key limitations of the use of electric motors in in-vivo applications. Fluid power in the form of hydraulics or pneumatics has a long history in driving many industrial devices and could be exploited to circumvent these limitations. High power density and good compatibility with the in-vivo environment are the key advantages of fluid power over electric motors when it comes to in-vivo applications. However, fabrication of hydraulic/pneumatic actuators within the desired size and pressure range required for in-vivo surgical robotic applications poses new challenges. Sealing these types of miniature actuators at operating pressures requires obtaining very fine surface finishes which is difficult and costly. The research described here presents design, fabrication, and testing of a hydraulic/pneumatic double-acting cylinder, a limited-motion vane motor, and a balloon-actuated laparoscopic grasper. These actuators are small, seal-less, easy to fabricate, disposable, and inexpensive, thus ideal for single-use in-vivo applications. To demonstrate the ability of these actuators to drive robotic joints, they were modified and integrated in a robotic arm. The design and testing of this surgical robotic arm are presented to validate the concept of fluid-power actuators for in-vivo applications.

  13. Regolith Advanced Surface Systems Operations Robot (RASSOR) Phase 2 and Smart Autonomous Sand-Swimming Excavator

    Science.gov (United States)

    Sandy, Michael

    2015-01-01

    The Regolith Advanced Surface Systems Operations Robot (RASSOR) Phase 2 is an excavation robot for mining regolith on a planet like Mars. The robot is programmed using the Robotic Operating System (ROS) and it also uses a physical simulation program called Gazebo. This internship focused on various functions of the program in order to make it a more professional and efficient robot. During the internship another project called the Smart Autonomous Sand-Swimming Excavator was worked on. This is a robot that is designed to dig through sand and extract sample material. The intern worked on programming the Sand-Swimming robot, and designing the electrical system to power and control the robot.

  14. Methodology for cloud-based design of robots

    Science.gov (United States)

    Ogorodnikova, O. M.; Vaganov, K. A.; Putimtsev, I. D.

    2017-09-01

    This paper presents some important results for cloud-based designing a robot arm by a group of students. Methodology for the cloud-based design was developed and used to initiate interdisciplinary project about research and development of a specific manipulator. The whole project data files were hosted by Ural Federal University data center. The 3D (three-dimensional) model of the robot arm was created using Siemens PLM software (Product Lifecycle Management) and structured as a complex mechatronics product by means of Siemens Teamcenter thin client; all processes were performed in the clouds. The robot arm was designed in purpose to load blanks up to 1 kg into the work space of the milling machine for performing student's researches.

  15. Integrated Human-Robotic Missions to the Moon and Mars: Mission Operations Design Implications

    Science.gov (United States)

    Mishkin, Andrew; Lee, Young; Korth, David; LeBlanc, Troy

    2007-01-01

    For most of the history of space exploration, human and robotic programs have been independent, and have responded to distinct requirements. The NASA Vision for Space Exploration calls for the return of humans to the Moon, and the eventual human exploration of Mars; the complexity of this range of missions will require an unprecedented use of automation and robotics in support of human crews. The challenges of human Mars missions, including roundtrip communications time delays of 6 to 40 minutes, interplanetary transit times of many months, and the need to manage lifecycle costs, will require the evolution of a new mission operations paradigm far less dependent on real-time monitoring and response by an Earthbound operations team. Robotic systems and automation will augment human capability, increase human safety by providing means to perform many tasks without requiring immediate human presence, and enable the transfer of traditional mission control tasks from the ground to crews. Developing and validating the new paradigm and its associated infrastructure may place requirements on operations design for nearer-term lunar missions. The authors, representing both the human and robotic mission operations communities, assess human lunar and Mars mission challenges, and consider how human-robot operations may be integrated to enable efficient joint operations, with the eventual emergence of a unified exploration operations culture.

  16. Vision-based robotic system for object agnostic placing operations

    DEFF Research Database (Denmark)

    Rofalis, Nikolaos; Nalpantidis, Lazaros; Andersen, Nils Axel

    2016-01-01

    Industrial robots are part of almost all modern factories. Even though, industrial robots nowadays manipulate objects of a huge variety in different environments, exact knowledge about both of them is generally assumed. The aim of this work is to investigate the ability of a robotic system to ope...... to the system, neither for the objects nor for the placing box. The experimental evaluation of the developed robotic system shows that a combination of seemingly simple modules and strategies can provide effective solution to the targeted problem....... to operate within an unknown environment manipulating unknown objects. The developed system detects objects, finds matching compartments in a placing box, and ultimately grasps and places the objects there. The developed system exploits 3D sensing and visual feature extraction. No prior knowledge is provided...

  17. Sedimentological Investigations of the Martian Surface using the Mars 2001 Robotic Arm Camera and MECA Optical Microscope

    Science.gov (United States)

    Rice, J. W., Jr.; Smith, P. H.; Marshall, J. R.

    1999-01-01

    The first microscopic sedimentological studies of the Martian surface will commence with the landing of the Mars Polar Lander (MPL) December 3, 1999. The Robotic Arm Camera (RAC) has a resolution of 25 um/p which will permit detailed micromorphological analysis of surface and subsurface materials. The Robotic Ann will be able to dig up to 50 cm below the surface. The walls of the trench will also be inspected by RAC to look for evidence of stratigraphic and / or sedimentological relationships. The 2001 Mars Lander will build upon and expand the sedimentological research begun by the RAC on MPL. This will be accomplished by: (1) Macroscopic (dm to cm): Descent Imager, Pancam, RAC; (2) Microscopic (mm to um RAC, MECA Optical Microscope (Figure 2), AFM This paper will focus on investigations that can be conducted by the RAC and MECA Optical Microscope.

  18. Navigation Strategy by Contact Sensing Interaction for a Biped Humanoid Robot

    Directory of Open Access Journals (Sweden)

    Hanafiah Yussof

    2008-11-01

    Full Text Available This report presents a basic contact interaction-based navigation strategy for a biped humanoid robot to support current visual-based navigation. The robot's arms were equipped with force sensors to detect physical contact with objects. We proposed a motion algorithm consisting of searching tasks, self-localization tasks, correction of locomotion direction tasks and obstacle avoidance tasks. Priority was given to right-side direction to navigate the robot locomotion. Analysis of trajectory generation, biped gait pattern, and biped walking characteristics was performed to define an efficient navigation strategy in a biped walking humanoid robot. The proposed algorithm is evaluated in an experiment with a 21-dofs humanoid robot operating in a room with walls and obstacles. The experimental results reveal good robot performance when recognizing objects by touching, grasping, and continuously generating suitable trajectories to correct direction and avoid collisions.

  19. A new AS-display as part of the MIRO lightweight robot for surgical applications

    Science.gov (United States)

    Grossmann, Christoph M.

    2010-02-01

    The DLR MIRO is the second generation of versatile robot arms for surgical applications, developed at the Institute for Robotics and Mechatronics at Deutsche Zentrum für Luft- und Raumfahrt (DLR) in Oberpfaffenhofen, Germany. With its low weight of 10 kg and dimensions similar to those of the human arm, the MIRO robot can assist the surgeon directly at the operating table where space is scarce. The planned scope of applications of this robot arm ranges from guiding a laser unit for the precise separation of bone tissue in orthopedics to positioning holes for bone screws, robot assisted endoscope guidance and on to the multi-robot concept for endoscopic minimally invasive surgery. A stereo-endoscope delivers two full HD video streams that can even be augmented with information, e.g vectors indicating the forces that act on the surgical tool at any given moment. SeeFront's new autostereoscopic 3D display SF 2223, being a part of the MIRO assembly, will let the surgeon view the stereo video stream in excellent quality, in real time and without the need for any viewing aids. The presentation is meant to provide an insight into the principles at the basis of the SeeFront 3D technology and how they allow the creation of autostereoscopic display solutions ranging from smallest "stamp-sized" displays to 30" desktop versions, which all provide comfortable freedom of movement for the viewer along with excellent 3D image quality.

  20. Space station automation and robotics study. Operator-systems interface

    Science.gov (United States)

    1984-01-01

    This is the final report of a Space Station Automation and Robotics Planning Study, which was a joint project of the Boeing Aerospace Company, Boeing Commercial Airplane Company, and Boeing Computer Services Company. The study is in support of the Advanced Technology Advisory Committee established by NASA in accordance with a mandate by the U.S. Congress. Boeing support complements that provided to the NASA Contractor study team by four aerospace contractors, the Stanford Research Institute (SRI), and the California Space Institute. This study identifies automation and robotics (A&R) technologies that can be advanced by requirements levied by the Space Station Program. The methodology used in the study is to establish functional requirements for the operator system interface (OSI), establish the technologies needed to meet these requirements, and to forecast the availability of these technologies. The OSI would perform path planning, tracking and control, object recognition, fault detection and correction, and plan modifications in connection with extravehicular (EV) robot operations.

  1. Robot-operated quality control station based on the UTT method

    Science.gov (United States)

    Burghardt, Andrzej; Kurc, Krzysztof; Szybicki, Dariusz; Muszyńska, Magdalena; Nawrocki, Jacek

    2017-03-01

    This paper presents a robotic test stand for the ultrasonic transmission tomography (UTT) inspection of stator vane thickness. The article presents the method of the test stand design in Autodesk Robot Structural Analysis Professional 2013 software suite. The performance of the designed test stand solution was simulated in the RobotStudio software suite. The operating principle of the test stand measurement system is presented with a specific focus on the measurement strategy. The results of actual wall thickness measurements performed on stator vanes are presented.

  2. Feasibility Study of a Hand Guided Robotic Drill for Cochleostomy

    Directory of Open Access Journals (Sweden)

    Peter Brett

    2014-01-01

    Full Text Available The concept of a hand guided robotic drill has been inspired by an automated, arm supported robotic drill recently applied in clinical practice to produce cochleostomies without penetrating the endosteum ready for inserting cochlear electrodes. The smart tactile sensing scheme within the drill enables precise control of the state of interaction between tissues and tools in real-time. This paper reports development studies of the hand guided robotic drill where the same consistent outcomes, augmentation of surgeon control and skill, and similar reduction of induced disturbances on the hearing organ are achieved. The device operates with differing presentation of tissues resulting from variation in anatomy and demonstrates the ability to control or avoid penetration of tissue layers as required and to respond to intended rather than involuntary motion of the surgeon operator. The advantage of hand guided over an arm supported system is that it offers flexibility in adjusting the drilling trajectory. This can be important to initiate cutting on a hard convex tissue surface without slipping and then to proceed on the desired trajectory after cutting has commenced. The results for trials on phantoms show that drill unit compliance is an important factor in the design.

  3. Reasons for singularity in robot teleoperation

    DEFF Research Database (Denmark)

    Marhenke, Ilka; Fischer, Kerstin; Savarimuthu, Thiusius Rajeeth

    2014-01-01

    In this paper, the causes for singularity of a robot arm in teleoperation for robot learning from demonstration are analyzed. Singularity is the alignment of robot joints, which prevents the configuration of the inverse kinematics. Inspired by users' own hypotheses, we investigated speed and dela...

  4. Robot operating system (ROS) the complete reference

    CERN Document Server

    The objective of this book is to provide the reader with a comprehensive coverage on the Robot Operating Systems (ROS) and latest related systems, which is currently considered as the main development framework for robotics applications. The book includes twenty-seven chapters organized into eight parts. Part 1 presents the basics and foundations of ROS. In Part 2, four chapters deal with navigation, motion and planning. Part 3 provides four examples of service and experimental robots. Part 4 deals with real-world deployment of applications. Part 5 presents signal-processing tools for perception and sensing. Part 6 provides software engineering methodologies to design complex software with ROS. Simulations frameworks are presented in Part 7. Finally, Part 8 presents advanced tools and frameworks for ROS including multi-master extension, network introspection, controllers and cognitive systems. This book will be a valuable companion for ROS users and developers to learn more ROS capabilities and features.   ...

  5. Usability testing of the human-machine interface for the Light Duty Utility Arm System

    International Nuclear Information System (INIS)

    Kiebel, G.R.; Ellis, J.E.; Masliah, M.R.

    1994-01-01

    This report describes the usability testing that has been done for the control and data acquisition system for the Light Duty Utility Arm (LDUA) System. A program of usability testing has been established as a part of a process for making the LDUA as easy to use as possible. The LDUA System is being designed to deploy a family of tools, called End Effectors, into underground storage tanks by means of a robotic arm on the end of a telescoping mast, and to collect and manage the data that they generate. The LDUA System uses a vertical positioning mast, to lower the arm into a tank through an existing 30.5 cm access riser. A Mobile Deployment Subsystem is used to position the mast and arm over a tank riser for deployment, and to transport them from tank to tank. The LDUA System has many ancillary subsystems including the Operations Control Trailer, the Tank Riser Interface and Confinement Subsystem, the Decontamination Subsystem, and the End Effector Exchange Subsystem. This work resulted in the identification of several important improvements to the LDUA control and data acquisition system before the design was frozen. The most important of these were color coding of joints in motion, simultaneous operator control of multiple joints, and changes to the field-of-views of the camera lenses for the robot and other camera systems

  6. Enhanced operator perception through 3D vision and haptic feedback

    Science.gov (United States)

    Edmondson, Richard; Light, Kenneth; Bodenhamer, Andrew; Bosscher, Paul; Wilkinson, Loren

    2012-06-01

    Polaris Sensor Technologies (PST) has developed a stereo vision upgrade kit for TALON® robot systems comprised of a replacement gripper camera and a replacement mast zoom camera on the robot, and a replacement display in the Operator Control Unit (OCU). Harris Corporation has developed a haptic manipulation upgrade for TALON® robot systems comprised of a replacement arm and gripper and an OCU that provides haptic (force) feedback. PST and Harris have recently collaborated to integrate the 3D vision system with the haptic manipulation system. In multiple studies done at Fort Leonard Wood, Missouri it has been shown that 3D vision and haptics provide more intuitive perception of complicated scenery and improved robot arm control, allowing for improved mission performance and the potential for reduced time on target. This paper discusses the potential benefits of these enhancements to robotic systems used for the domestic homeland security mission.

  7. An expert system for automated robotic grasping

    International Nuclear Information System (INIS)

    Stansfield, S.A.

    1990-01-01

    Many US Department of Energy sites and facilities will be environmentally remediated during the next several decades. A number of the restoration activities (e.g., decontamination and decommissioning of inactive nuclear facilities) can only be carried out by remote means and will be manipulation-intensive tasks. Experience has shown that manipulation tasks are especially slow and fatiguing for the human operator of a remote manipulator. In this paper, the authors present a rule-based expert system for automated, dextrous robotic grasping. This system interprets the features of an object to generate hand shaping and wrist orientation for a robot hand and arm. The system can be used in several different ways to lessen the demands on the human operator of a remote manipulation system - either as a fully autonomous grasping system or one that generates grasping options for a human operator and then automatically carries out the selected option

  8. Application of automation and robotics to lunar surface human exploration operations

    Science.gov (United States)

    Woodcock, Gordon R.; Sherwood, Brent; Buddington, Patricia A.; Bares, Leona C.; Folsom, Rolfe; Mah, Robert; Lousma, Jack

    1990-01-01

    Major results of a study applying automation and robotics to lunar surface base buildup and operations concepts are reported. The study developed a reference base scenario with specific goals, equipment concepts, robot concepts, activity schedules and buildup manifests. It examined crew roles, contingency cases and system reliability, and proposed a set of technologies appropriate and necessary for effective lunar operations. This paper refers readers to four companion papers for quantitative details where appropriate.

  9. Step-by-Step robotic heminephrectomy for duplicated renal collecting system

    Directory of Open Access Journals (Sweden)

    Homayoun Zargar

    2014-08-01

    Full Text Available Introduction A duplicated renal collecting system is a relatively common congenital anomaly rarely presenting in adults. Aim In this video we demonstrate our step-by-step technique of Robotic heminephrectomy in a patient with non-functioning upper pole moiety. Materials and Methods Following cystoscopy and ureteral catheter insertion the patient was placed in 600 modified flank position with the ipsilateral arm positioned at the side of the patient. A straight-line, three arm robotic port configuration was employed. The robot was docked at a 90-degree angle, perpendicular to the patient. Following mobilization the colon and identifying both ureters of the duplicated system, the ureters were followed cephalically toward, hilar vessels where the hilar anatomy was identified. The nonfunctioning pole vasculature was ligated using hem-o-lok clips. The ureter was sharply divided and the proximal ureteral stump was passed posterior the renal hilum. Ureteral stump was used as for retraction and heminephrectomy is completed along the line demarcating the upper and lower pole moieties. Renorrhaphy was performed using 0-Vicryl suture with a CT-1 needle. The nonfunctioning pole ureter was then dissected caudally toward the bladder hiatus, ligated using clips, and transected. Results The operating time was 240 minutes and blood loss was 100 cc. There was no complication post-operatively. Conclusions Wrist articulation and degree of freedom offered by robotic platform facilitates successful performance of minimally invasive heminephrectomy in the setting of an atrophic and symptomatic renal segment.

  10. Reverse engineering of the robot base platform

    International Nuclear Information System (INIS)

    Anwar A Rahman; Azizul Rahman A Aziz; Mohd Arif Hamzah; Muhd Nor Atan; Fadil Ismail; Rosli Darmawan

    2009-01-01

    The robot base platform used to place the robotic arm version 2 was imported through a local company. The robot base platform is used as a reference for reverse egineering development for a smaller size robot. The paper will discuss the reverse engineering design process and parameters involved in the development of the robot base platform. (Author)

  11. Robotic-assisted laparoscopic radical nephrectomy using the Da Vinci Si system: how to improve surgeon autonomy. Our step-by-step technique.

    Science.gov (United States)

    Davila, Hugo H; Storey, Raul E; Rose, Marc C

    2016-09-01

    Herein, we describe several steps to improve surgeon autonomy during a Left Robotic-Assisted Laparoscopic Radical Nephrectomy (RALRN), using the Da Vinci Si system. Our kidney cancer program is based on 2 community hospitals. We use the Da Vinci Si system. Access is obtained with the following trocars: Two 8 mm robotic, one 8 mm robotic, bariatric length (arm 3), 15 mm for the assistant and 12 mm for the camera. We use curved monopolar scissors in robotic arm 1, Bipolar Maryland in arm 2, Prograsp Forceps in arm 3, and we alternate throughout the surgery with EndoWrist clip appliers and the vessel sealer. Here, we described three steps and the use of 3 robotic instruments to improve surgeon autonomy. Step 1: the lower pole of the kidney was dissected and this was retracted upwards and laterally. This maneuver was performed using the 3rd robotic arm with the Prograsp Forceps. Step 2: the monopolar scissors was replaced (robotic arm 1) with the robotic EndoWrist clip applier, 10 mm Hem-o-Lok. The renal artery and vein were controlled and transected by the main surgeon. Step 3: the superior, posterolateral dissection and all bleeders were carefully coagulated by the surgeon with the EndoWrist one vessel sealer. We have now performed 15 RALRN following these steps. Our results were: blood loss 300 cc, console time 140 min, operating room time 200 min, anesthesia time 180 min, hospital stay 2.5 days, 1 incisional hernia, pathology: (13) RCC clear cell, (1) chromophobe and (1) papillary type 1. Tumor Stage: (5) T1b, (8) T2a, (2) T2b. We provide a concise, step-by-step technique for radical nephrectomy (RN) using the Da Vinci Si robotic system that may provide more autonomy to the surgeon, while maintaining surgical outcome equivalent to standard laparoscopic RN.

  12. Space robot simulator vehicle

    Science.gov (United States)

    Cannon, R. H., Jr.; Alexander, H.

    1985-01-01

    A Space Robot Simulator Vehicle (SRSV) was constructed to model a free-flying robot capable of doing construction, manipulation and repair work in space. The SRSV is intended as a test bed for development of dynamic and static control methods for space robots. The vehicle is built around a two-foot-diameter air-cushion vehicle that carries batteries, power supplies, gas tanks, computer, reaction jets and radio equipment. It is fitted with one or two two-link manipulators, which may be of many possible designs, including flexible-link versions. Both the vehicle body and its first arm are nearly complete. Inverse dynamic control of the robot's manipulator has been successfully simulated using equations generated by the dynamic simulation package SDEXACT. In this mode, the position of the manipulator tip is controlled not by fixing the vehicle base through thruster operation, but by controlling the manipulator joint torques to achieve the desired tip motion, while allowing for the free motion of the vehicle base. One of the primary goals is to minimize use of the thrusters in favor of intelligent control of the manipulator. Ways to reduce the computational burden of control are described.

  13. Image-guided robotic surgery.

    Science.gov (United States)

    Marescaux, Jacques; Solerc, Luc

    2004-06-01

    Medical image processing leads to an improvement in patient care by guiding the surgical gesture. Three-dimensional models of patients that are generated from computed tomographic scans or magnetic resonance imaging allow improved surgical planning and surgical simulation that offers the opportunity for a surgeon to train the surgical gesture before performing it for real. These two preoperative steps can be used intra-operatively because of the development of augmented reality, which consists of superimposing the preoperative three-dimensional model of the patient onto the real intraoperative view. Augmented reality provides the surgeon with a view of the patient in transparency and can also guide the surgeon, thanks to the real-time tracking of surgical tools during the procedure. When adapted to robotic surgery, this tool tracking enables visual serving with the ability to automatically position and control surgical robotic arms in three dimensions. It is also now possible to filter physiologic movements such as breathing or the heart beat. In the future, by combining augmented reality and robotics, these image-guided robotic systems will enable automation of the surgical procedure, which will be the next revolution in surgery.

  14. Application of visual servoing for grasping and placing operation in slaughterhouse

    DEFF Research Database (Denmark)

    Wu, Haiyan; Andersen, Thomas Timm; Andersen, Nils Axel

    2017-01-01

    of the target the color information provided by a visual sensor is utilized. The control command for the robot is generated based on the real time visual feedback. An industrial robot arm UR10 is applied to complete the operation. A lab-scale experimental setup is constructed for system validation...

  15. Robotic Materials Handling in Space: Mechanical Design of the Robot Operated Materials Processing System HitchHiker Experiment

    Science.gov (United States)

    Voellmer, George

    1997-01-01

    The Goddard Space Flight Center has developed the Robot Operated Materials Processing System (ROMPS) that flew aboard STS-64 in September, 1994. The ROMPS robot transported pallets containing wafers of different materials from their storage racks to a furnace for thermal processing. A system of tapered guides and compliant springs was designed to deal with the potential misalignments. The robot and all the sample pallets were locked down for launch and landing. The design of the passive lockdown system, and the interplay between it and the alignment system are presented.

  16. A new neural net approach to robot 3D perception and visuo-motor coordination

    Science.gov (United States)

    Lee, Sukhan

    1992-01-01

    A novel neural network approach to robot hand-eye coordination is presented. The approach provides a true sense of visual error servoing, redundant arm configuration control for collision avoidance, and invariant visuo-motor learning under gazing control. A 3-D perception network is introduced to represent the robot internal 3-D metric space in which visual error servoing and arm configuration control are performed. The arm kinematic network performs the bidirectional association between 3-D space arm configurations and joint angles, and enforces the legitimate arm configurations. The arm kinematic net is structured by a radial-based competitive and cooperative network with hierarchical self-organizing learning. The main goal of the present work is to demonstrate that the neural net representation of the robot 3-D perception net serves as an important intermediate functional block connecting robot eyes and arms.

  17. Robotics Scoping Study to Evaluate Advances in Robotics Technologies that Support Enhanced Efficiencies for Yucca Mountain Repository Operations

    International Nuclear Information System (INIS)

    Burgess, T.; Noakes, M.; Spampinato, P.

    2005-01-01

    This paper presents an evaluation of robotics and remote handling technologies that have the potential to increase the efficiency of handling waste packages at the proposed Yucca Mountain High-Level Nuclear Waste Repository. It is expected that increased efficiency will reduce the cost of operations. The goal of this work was to identify technologies for consideration as potential projects that the U.S. Department of Energy Office of Civilian Radioactive Waste Management, Office of Science and Technology International Programs, could support in the near future, and to assess their ''payback'' value. The evaluation took into account the robotics and remote handling capabilities planned for incorporation into the current baseline design for the repository, for both surface and subsurface operations. The evaluation, completed at the end of fiscal year 2004, identified where significant advantages in operating efficiencies could accrue by implementing any given robotics technology or approach, and included a road map for a multiyear R and D program for improvements to remote handling technology that support operating enhancements

  18. Robotics Scoping Study to Evaluate Advances in Robotics Technologies that Support Enhanced Efficiencies for Yucca Mountain Repository Operations

    Energy Technology Data Exchange (ETDEWEB)

    T. Burgess; M. Noakes; P. Spampinato

    2005-03-17

    This paper presents an evaluation of robotics and remote handling technologies that have the potential to increase the efficiency of handling waste packages at the proposed Yucca Mountain High-Level Nuclear Waste Repository. It is expected that increased efficiency will reduce the cost of operations. The goal of this work was to identify technologies for consideration as potential projects that the U.S. Department of Energy Office of Civilian Radioactive Waste Management, Office of Science and Technology International Programs, could support in the near future, and to assess their ''payback'' value. The evaluation took into account the robotics and remote handling capabilities planned for incorporation into the current baseline design for the repository, for both surface and subsurface operations. The evaluation, completed at the end of fiscal year 2004, identified where significant advantages in operating efficiencies could accrue by implementing any given robotics technology or approach, and included a road map for a multiyear R&D program for improvements to remote handling technology that support operating enhancements.

  19. A robotic system for automation of logistics functions on the Space Station

    Science.gov (United States)

    Martin, J. C.; Purves, R. B.; Hosier, R. N.; Krein, B. A.

    1988-01-01

    Spacecraft inventory management is currently performed by the crew and as systems become more complex, increased crew time will be required to perform routine logistics activities. If future spacecraft are to function effectively as research labs and production facilities, the efficient use of crew time as a limited resource for performing mission functions must be employed. The use of automation and robotics technology, such as automated warehouse and materials handling functions, can free the crew from many logistics tasks and provide more efficient use of crew time. Design criteria for a Space Station Automated Logistics Inventory Management System is focused on through the design and demonstration of a mobile two armed terrestrial robot. The system functionally represents a 0 gravity automated inventory management system and the problems associated with operating in such an environment. Features of the system include automated storage and retrieval, item recognition, two armed robotic manipulation, and software control of all inventory item transitions and queries.

  20. Internet remote control interface for a multipurpose robotic arm

    Directory of Open Access Journals (Sweden)

    Matthew W. Dunnigan

    2008-11-01

    Full Text Available This paper presents an Internet remote control interface for a MITSUBISHI PA10-6CE manipulator established for the purpose of the ROBOT museum exhibition during spring and summer 2004. The robotic manipulator is a part of the Intelligent Robotic Systems Laboratory at Heriot ? Watt University, which has been established to work on dynamic and kinematic aspects of manipulator control in the presence of environmental disturbances. The laboratory has been enriched by a simple vision system consisting of three web-cameras to broadcast the live images of the robots over the Internet. The Interface comprises of the TCP/IP server providing command parsing and execution using the open controller architecture of the manipulator and a client Java applet web-site providing a simple robot control interface.

  1. Human-Robot Interaction Directed Research Project

    Science.gov (United States)

    Rochlis, Jennifer; Ezer, Neta; Sandor, Aniko

    2011-01-01

    studies, participants performance during teleoperation of a robot arm will be compared when they are provided with command-guidance symbology (that is, directing the operator what commands to make) or situation-guidance symbology (that is, providing natural cues so that the operator can infer what commands to make). The second factor for AR symbology is the effects of overlays that are either superimposed or integrated into the external view of the world. A study is proposed in which the effects of superimposed and integrated overlays on operator task performance during teleoperated driving tasks are compared

  2. ROS (Robot Operating System) für Automotive

    OpenAIRE

    Bubeck, Alexander

    2014-01-01

    - Introduction into the Robot Operating System - Open Source in the automotive industries - Application of ROS in the automotive industry - ROS navigation - ROS with real time control - ROS in the embedded world - Outlook: ROS 2.0 - Summary

  3. Design criteria for the light duty utility arm system end effectors

    International Nuclear Information System (INIS)

    Pardini, A.F.

    1995-01-01

    This document provides the criteria for the design of end effectors that will be used as part of the Light Duty Utility Arm (LDUA) System. The LDUA System consists of a deployment vehicle, a vertical positioning mast, a light duty multi-axis robotic arm, a tank riser interface and confinement, a tool interface plate, a control system, and an operations control trailer. The criteria specified in this document will apply to all end effector systems being developed for use on or with the LDUA system at the Hanford site. The requirement stipulated in this document are mandatory

  4. Automation and Robotics for space operation and planetary exploration

    Science.gov (United States)

    Montemerlo, Melvin D.

    1990-01-01

    This paper presents a perspective of Automation and Robotics (A&R) research and developments at NASA in terms of its history, its current status, and its future. It covers artificial intelligence, telerobotics and planetary rovers, and it encompasses ground operations, operations in earth orbit, and planetary exploration.

  5. Soft Robotics: Biological Inspiration, State of the Art, and Future Research

    Directory of Open Access Journals (Sweden)

    Deepak Trivedi

    2008-01-01

    Full Text Available Traditional robots have rigid underlying structures that limit their ability to interact with their environment. For example, conventional robot manipulators have rigid links and can manipulate objects using only their specialised end effectors. These robots often encounter difficulties operating in unstructured and highly congested environments. A variety of animals and plants exhibit complex movement with soft structures devoid of rigid components. Muscular hydrostats (e.g. octopus arms and elephant trunks are almost entirely composed of muscle and connective tissue and plant cells can change shape when pressurised by osmosis. Researchers have been inspired by biology to design and build soft robots. With a soft structure and redundant degrees of freedom, these robots can be used for delicate tasks in cluttered and/or unstructured environments. This paper discusses the novel capabilities of soft robots, describes examples from nature that provide biological inspiration, surveys the state of the art and outlines existing challenges in soft robot design, modelling, fabrication and control.

  6. Visual Attention Allocation Between Robotic Arm and Environmental Process Control: Validating the STOM Task Switching Model

    Science.gov (United States)

    Wickens, Christopher; Vieanne, Alex; Clegg, Benjamin; Sebok, Angelia; Janes, Jessica

    2015-01-01

    Fifty six participants time shared a spacecraft environmental control system task with a realistic space robotic arm control task in either a manual or highly automated version. The former could suffer minor failures, whose diagnosis and repair were supported by a decision aid. At the end of the experiment this decision aid unexpectedly failed. We measured visual attention allocation and switching between the two tasks, in each of the eight conditions formed by manual-automated arm X expected-unexpected failure X monitoring- failure management. We also used our multi-attribute task switching model, based on task attributes of priority interest, difficulty and salience that were self-rated by participants, to predict allocation. An un-weighted model based on attributes of difficulty, interest and salience accounted for 96 percent of the task allocation variance across the 8 different conditions. Task difficulty served as an attractor, with more difficult tasks increasing the tendency to stay on task.

  7. The Arrival of Robotics in Spine Surgery: A Review of the Literature.

    Science.gov (United States)

    Ghasem, Alexander; Sharma, Akhil; Greif, Dylan N; Alam, Milad; Maaieh, Motasem Al

    2018-04-18

    Systematic Review. The authors aim to review comparative outcome measures between robotic and free-hand spine surgical procedures including: accuracy of spinal instrumentation, radiation exposure, operative time, hospital stay, and complication rates. Misplacement of pedicle screws in conventional open as well as minimally invasive surgical procedures has prompted the need for innovation and allowed the emergence of robotics in spine surgery. Prior to incorporation of robotic surgery in routine practice, demonstration of improved instrumentation accuracy, operative efficiency, and patient safety is required. A systematic search of the PubMed, OVID-MEDLINE, and Cochrane databases was performed for papers relevant to robotic assistance of pedicle screw placement. Inclusion criteria were constituted by English written randomized control trials, prospective and retrospective cohort studies involving robotic instrumentation in the spine. Following abstract, title, and full-text review, 32 articles were selected for study inclusion. Intrapedicular accuracy in screw placement and subsequent complications were at least comparable if not superior in the robotic surgery cohort. There is evidence supporting that total operative time is prolonged in robot assisted surgery compared to conventional free-hand. Radiation exposure appeared to be variable between studies; radiation time did decrease in the robot arm as the total number of robotic cases ascended, suggesting a learning curve effect. Multi-level procedures appeared to tend toward earlier discharge in patients undergoing robotic spine surgery. The implementation of robotic technology for pedicle screw placement yields an acceptable level of accuracy on a highly consistent basis. Surgeons should remain vigilant about confirmation of robotic assisted screw trajectory, as drilling pathways have been shown to be altered by soft tissue pressures, forceful surgical application, and bony surface skiving. However, the effective

  8. Remote Viewing End Effectors for Light Duty Utility Arm Robot (U)

    International Nuclear Information System (INIS)

    Heckendorn, F.M.; Robinson, C.W.; Haynes, H.B.; Anderosn, E.K.; Pardini, A.F.

    1996-01-01

    The Robotics Development Groups at the Savannah River Site (SRS) and at the Hanford site have developed remote video and photography systems for deployment in underground radioactive-waste storage tanks at the Department of Energy (DOE) sites as a part of the Office of Science and Technology (OST) program within DOE. Viewing and documenting the tank interiors and their associated annular spaces is an extremely valuable tool in characterizing their condition and contents and in controlling their remediation. Several specialized video/photography systems and robotic End Effectors have been fabricated that provide remote viewing and lighting. All are remotely deployable into and out of the tank, with all viewing functions remotely operated. Positioning all control components away from the facility prevents the potential for personnel exposure to radiation and contamination. Only the remote video systems are discussed in this paper

  9. Tactile Robotic Topographical Mapping Without Force or Contact Sensors

    Science.gov (United States)

    Burke, Kevin; Melko, Joseph; Krajewski, Joel; Cady, Ian

    2008-01-01

    A method of topographical mapping of a local solid surface within the range of motion of a robot arm is based on detection of contact between the surface and the end effector (the fixture or tool at the tip of the robot arm). The method was conceived to enable mapping of local terrain by an exploratory robot on a remote planet, without need to incorporate delicate contact switches, force sensors, a vision system, or other additional, costly hardware. The method could also be used on Earth for determining the size and shape of an unknown surface in the vicinity of a robot, perhaps in an unanticipated situation in which other means of mapping (e.g., stereoscopic imaging or laser scanning with triangulation) are not available. The method uses control software modified to utilize the inherent capability of the robotic control system to measure the joint positions, the rates of change of the joint positions, and the electrical current demanded by the robotic arm joint actuators. The system utilizes these coordinate data and the known robot-arm kinematics to compute the position and velocity of the end effector, move the end effector along a specified trajectory, place the end effector at a specified location, and measure the electrical currents in the joint actuators. Since the joint actuator current is approximately proportional to the actuator forces and torques, a sudden rise in joint current, combined with a slowing of the joint, is a possible indication of actuator stall and surface contact. Hence, even though the robotic arm is not equipped with contact sensors, it is possible to sense contact (albeit with reduced sensitivity) as the end effector becomes stalled against a surface that one seeks to measure.

  10. Robot arm based flat panel CT-guided electromagnetic tracked spine interventions: phantom and animal model experiments

    Energy Technology Data Exchange (ETDEWEB)

    Penzkofer, Tobias; Isfort, Peter; Bruners, Philipp; Mahnken, Andreas H. [RWTH Aachen University, Applied Medical Engineering, Helmholtz-Institute Aachen, Aachen (Germany); RWTH Aachen University, Department of Diagnostic Radiology, Aachen University Hospital, Aachen (Germany); Wiemann, Christian; Guenther, Rolf W. [RWTH Aachen University, Department of Diagnostic Radiology, Aachen University Hospital, Aachen (Germany); Kyriakou, Yiannis; Kalender, Willi A. [Friedrich-Alexander University of Erlangen-Nuremberg, Institute for Medical Physics, Erlangen (Germany); Schmitz-Rode, Thomas [RWTH Aachen University, Applied Medical Engineering, Helmholtz-Institute Aachen, Aachen (Germany)

    2010-11-15

    To evaluate accuracy and procedure times of electromagnetic tracking (EMT) in a robotic arm mounted flat panel setting using phantom and animal cadaveric models. A robotic arm mounted flat panel (RMFP) was used in combination with EMT to perform anthropomorphic phantom (n = 90) and ex vivo pig based punctures (n = 120) of lumbar facet joints (FJ, n = 120) and intervertebral discs (IVD, n = 90). Procedure accuracies and times were assessed and evaluated. FJ punctures were carried out with a spatial accuracy of 0.8 {+-} 0.9 mm (phantom) and 0.6 {+-} 0.8 mm (ex vivo) respectively. While IVD punctures showed puncture deviations of 0.6 {+-} 1.2 mm (phantom) and 0.5 {+-} 0.6 mm (ex vivo), direct and angulated phantom based punctures had accuracies of 0.8 {+-} 0.9 mm and 1.0 {+-} 1.3 mm. Planning took longer for ex vivo IVD punctures compared to phantom model interventions (39.3 {+-} 17.3 s vs. 20.8 {+-} 5.0 s, p = 0.001) and for angulated vs. direct phantom FJ punctures (19.7 {+-} 5.1 s vs. 28.6 {+-} 7.8 s, p < 0.001). Puncture times were longer for ex vivo procedures when compared to phantom model procedures in both FJ (37.9 {+-} 9.0 s vs. 23.6 {+-} 7.2 s, p = 0.001) and IVD punctures (43.9 {+-} 16.1 s vs. 31.1 {+-} 6.4 s, p = 0.026). The combination of RMFP with EMT provides an accurate method of navigation for spinal interventions such as facet joint punctures and intervertebral disc punctures. (orig.)

  11. Robot hand tackles jobs in hazardous areas

    International Nuclear Information System (INIS)

    Simms, Mark; Crowder, Richard.

    1989-01-01

    A robot hand and arm designed to mimic the operation of its human counterpart, developed at the University of Southampton for use in a standard industrial glovebox, is described. It was specifically designed for use in a radioactive environment moving high dosage components around. As dosage limits go down, there is a legal requirement to remove people from that environment. The nine-axis arm is for use in a glove designed for a human hand. Drive for the motors used to power the hand is from three-phase MOSFET inventor cards, the switching pattern controlled by the Hall effect communication sensors integral to each motor. The computer software for the arm allows the hand to be positioned using a joystick on a control box, with three levels of command for grip, pinch and touch. (author)

  12. Bio-Inspired Genetic Algorithms with Formalized Crossover Operators for Robotic Applications.

    Science.gov (United States)

    Zhang, Jie; Kang, Man; Li, Xiaojuan; Liu, Geng-Yang

    2017-01-01

    Genetic algorithms are widely adopted to solve optimization problems in robotic applications. In such safety-critical systems, it is vitally important to formally prove the correctness when genetic algorithms are applied. This paper focuses on formal modeling of crossover operations that are one of most important operations in genetic algorithms. Specially, we for the first time formalize crossover operations with higher-order logic based on HOL4 that is easy to be deployed with its user-friendly programing environment. With correctness-guaranteed formalized crossover operations, we can safely apply them in robotic applications. We implement our technique to solve a path planning problem using a genetic algorithm with our formalized crossover operations, and the results show the effectiveness of our technique.

  13. Robotic assisted laparoscopic colectomy.

    LENUS (Irish Health Repository)

    Pandalai, S

    2010-06-01

    Robotic surgery has evolved over the last decade to compensate for limitations in human dexterity. It avoids the need for a trained assistant while decreasing error rates such as perforations. The nature of the robotic assistance varies from voice activated camera control to more elaborate telerobotic systems such as the Zeus and the Da Vinci where the surgeon controls the robotic arms using a console. Herein, we report the first series of robotic assisted colectomies in Ireland using a voice activated camera control system.

  14. Robot dispatching Scenario for Accident Condition Monitoring of NPP

    International Nuclear Information System (INIS)

    Kim, Jongseog

    2013-01-01

    In March of 2011, unanticipated big size of tsunami attacks Fukushima NPP, this accident results in explosion of containment building. Tokyo electric power of Japan couldn't dispatch a robot for monitoring of containment inside. USA Packbot robot used for desert war in Iraq was supplied to Fukushima NPP for monitoring of high radiation area. Packbot also couldn't reach deep inside of Fukushima NPP due to short length of power cable. Japanese robot 'Queens' also failed to complete a mission due to communication problem between robot and operator. I think major reason of these robot failures is absence of robot dispatching scenario. If there was a scenario and a rehearsal for monitoring during or after accident, these unanticipated obstacles could be overcome. Robot dispatching scenario studied for accident of nuclear power plant was described herein. Study on scenario of robot dispatching is performed. Flying robot is regarded as good choice for accident monitoring. Walking robot with arm equipped is good for emergency valve close. Short time work and shift work by several robots can be a solution for high radiation area. Thin and soft cable with rolling reel can be a good solution for long time work and good communication

  15. Design and implementation of wormlike creeping mobile robot for EAST remote maintenance system

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Qiang, E-mail: zhangqiang@iim.ac.cn [Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Department of Automation, University of Science and Technology of China, Hefei, Anhui 230026 (China); Zhou, Ling [Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Wang, Zengfu, E-mail: zfwang@ustc.edu.cn [Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Department of Automation, University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2017-05-15

    Highlights: • Wormlike creeping robot walking on the V-shaped circular slot in EAST fusion vessel. • Mobile platform to carry equipments or assist manipulators for maintenance tasks. • Chain structure design with n(n ≥ 2) creeping units each of which has three segments. • Creeping gait planning to construct a multi-axis coordinating control scheme. • Evaluation and verification of basic motion performance and mechanical properties. - Abstract: Maintenance for nuclear fusion vessel is crucial, yet it faces great difficulty due to the complex internal physical and geometric conditions. Since the limitation on inherent strength, load, size, etc, a manipulator robot can only complete very limited tasks. Robotic arm systems for remote operation such as JET and MPD can carry certain tools to complete a variety of operating tasks, but it is difficult to achieve the system which is very complex. Therefore, if the inherent idea of using a single robot to complete the specified functions can change, it is possible to make the problems simpler and easier to solve by adding auxiliary robots working together with the robotic arm systems to complete the assigned tasks. Under the above background, based on the deeply analyzing and refining the functional requirements of the vessel operation robot, proceeding from the perspective of ability to move and carry a certain operating device, this paper presents a wormlike creeping mobile robot walking on the V-shaped circular slot inside a nuclear fusion vessel such as EAST (Experimental Advanced Superconducting Tokamak). We have designed and implemented the principle prototype of the robot which has chain structure with n (n ≥2) creeping units. Each creeping unit is of three-part structure, which consists of fore segment, mid segment and back segment connected by bidirectional universal joint. The fore and back segments stretch the paws to contact the surface of V-shaped slot, while the mid segment realizes the overall

  16. Design and implementation of wormlike creeping mobile robot for EAST remote maintenance system

    International Nuclear Information System (INIS)

    Zhang, Qiang; Zhou, Ling; Wang, Zengfu

    2017-01-01

    Highlights: • Wormlike creeping robot walking on the V-shaped circular slot in EAST fusion vessel. • Mobile platform to carry equipments or assist manipulators for maintenance tasks. • Chain structure design with n(n ≥ 2) creeping units each of which has three segments. • Creeping gait planning to construct a multi-axis coordinating control scheme. • Evaluation and verification of basic motion performance and mechanical properties. - Abstract: Maintenance for nuclear fusion vessel is crucial, yet it faces great difficulty due to the complex internal physical and geometric conditions. Since the limitation on inherent strength, load, size, etc, a manipulator robot can only complete very limited tasks. Robotic arm systems for remote operation such as JET and MPD can carry certain tools to complete a variety of operating tasks, but it is difficult to achieve the system which is very complex. Therefore, if the inherent idea of using a single robot to complete the specified functions can change, it is possible to make the problems simpler and easier to solve by adding auxiliary robots working together with the robotic arm systems to complete the assigned tasks. Under the above background, based on the deeply analyzing and refining the functional requirements of the vessel operation robot, proceeding from the perspective of ability to move and carry a certain operating device, this paper presents a wormlike creeping mobile robot walking on the V-shaped circular slot inside a nuclear fusion vessel such as EAST (Experimental Advanced Superconducting Tokamak). We have designed and implemented the principle prototype of the robot which has chain structure with n (n ≥2) creeping units. Each creeping unit is of three-part structure, which consists of fore segment, mid segment and back segment connected by bidirectional universal joint. The fore and back segments stretch the paws to contact the surface of V-shaped slot, while the mid segment realizes the overall

  17. Dual Arm Work Package performance estimates and telerobot task network simulation

    International Nuclear Information System (INIS)

    Draper, J.V.

    1997-01-01

    This paper describes the methodology and results of a network simulation study of the Dual Arm Work Package (DAWP), to be employed for dismantling the Argonne National Laboratory CP-5 reactor. The development of the simulation model was based upon the results of a task analysis for the same system. This study was performed by the Oak Ridge National Laboratory (ORNL), in the Robotics and Process Systems Division. Funding was provided the US Department of Energy's Office of Technology Development, Robotics Technology Development Program (RTDP). The RTDP is developing methods of computer simulation to estimate telerobotic system performance. Data were collected to provide point estimates to be used in a task network simulation model. Three skilled operators performed six repetitions of a pipe cutting task representative of typical teleoperation cutting operations

  18. Robot modelling; Control and applications with software

    Energy Technology Data Exchange (ETDEWEB)

    Ranky, P G; Ho, C Y

    1985-01-01

    This book provides a ''picture'' of robotics covering both the theoretical aspect of modeling as well as the practical and design aspects of: robot programming; robot tooling and automated hand changing; implementation planning; testing; and software design for robot systems. The authors present an introduction to robotics with a systems approach. They describe not only the tasks relating to a single robot (or arm) but also systems of robots working together on a product or several products.

  19. Second Annual Workshop on Space Operations Automation and Robotics (SOAR 1988)

    Science.gov (United States)

    Griffin, Sandy (Editor)

    1988-01-01

    Papers presented at the Second Annual Workshop on Space Operation Automation and Robotics (SOAR '88), hosted by Wright State University at Dayton, Ohio, on July 20, 21, 22, and 23, 1988, are documented herein. During the 4 days, approximately 100 technical papers were presented by experts from NASA, the USAF, universities, and technical companies. Panel discussions on Human Factors, Artificial Intelligence, Robotics, and Space Systems were held but are not documented herein. Technical topics addressed included knowledge-based systems, human factors, and robotics.

  20. Multi-Robot Interfaces and Operator Situational Awareness: Study of the Impact of Immersion and Prediction.

    Science.gov (United States)

    Roldán, Juan Jesús; Peña-Tapia, Elena; Martín-Barrio, Andrés; Olivares-Méndez, Miguel A; Del Cerro, Jaime; Barrientos, Antonio

    2017-07-27

    Multi-robot missions are a challenge for operators in terms of workload and situational awareness. These operators have to receive data from the robots, extract information, understand the situation properly, make decisions, generate the adequate commands, and send them to the robots. The consequences of excessive workload and lack of awareness can vary from inefficiencies to accidents. This work focuses on the study of future operator interfaces of multi-robot systems, taking into account relevant issues such as multimodal interactions, immersive devices, predictive capabilities and adaptive displays. Specifically, four interfaces have been designed and developed: a conventional, a predictive conventional, a virtual reality and a predictive virtual reality interface. The four interfaces have been validated by the performance of twenty-four operators that supervised eight multi-robot missions of fire surveillance and extinguishing. The results of the workload and situational awareness tests show that virtual reality improves the situational awareness without increasing the workload of operators, whereas the effects of predictive components are not significant and depend on their implementation.

  1. Multi-Robot Interfaces and Operator Situational Awareness: Study of the Impact of Immersion and Prediction

    Science.gov (United States)

    Peña-Tapia, Elena; Martín-Barrio, Andrés; Olivares-Méndez, Miguel A.

    2017-01-01

    Multi-robot missions are a challenge for operators in terms of workload and situational awareness. These operators have to receive data from the robots, extract information, understand the situation properly, make decisions, generate the adequate commands, and send them to the robots. The consequences of excessive workload and lack of awareness can vary from inefficiencies to accidents. This work focuses on the study of future operator interfaces of multi-robot systems, taking into account relevant issues such as multimodal interactions, immersive devices, predictive capabilities and adaptive displays. Specifically, four interfaces have been designed and developed: a conventional, a predictive conventional, a virtual reality and a predictive virtual reality interface. The four interfaces have been validated by the performance of twenty-four operators that supervised eight multi-robot missions of fire surveillance and extinguishing. The results of the workload and situational awareness tests show that virtual reality improves the situational awareness without increasing the workload of operators, whereas the effects of predictive components are not significant and depend on their implementation. PMID:28749407

  2. Multi-Robot Interfaces and Operator Situational Awareness: Study of the Impact of Immersion and Prediction

    Directory of Open Access Journals (Sweden)

    Juan Jesús Roldán

    2017-07-01

    Full Text Available Multi-robot missions are a challenge for operators in terms of workload and situational awareness. These operators have to receive data from the robots, extract information, understand the situation properly, make decisions, generate the adequate commands, and send them to the robots. The consequences of excessive workload and lack of awareness can vary from inefficiencies to accidents. This work focuses on the study of future operator interfaces of multi-robot systems, taking into account relevant issues such as multimodal interactions, immersive devices, predictive capabilities and adaptive displays. Specifically, four interfaces have been designed and developed: a conventional, a predictive conventional, a virtual reality and a predictive virtual reality interface. The four interfaces have been validated by the performance of twenty-four operators that supervised eight multi-robot missions of fire surveillance and extinguishing. The results of the workload and situational awareness tests show that virtual reality improves the situational awareness without increasing the workload of operators, whereas the effects of predictive components are not significant and depend on their implementation.

  3. Use of a robotic manipulator in the simulation of the automation of a calibration process of dosemeters

    International Nuclear Information System (INIS)

    Benitez R, J.S.; Najera H, M.C.

    2002-01-01

    The development of a system based in a manipulative robot which simulates the operative sequence in a calibration process of dosemeters is presented. In this process it is performed the monitoring of the dosemeter positions and the calibrator by mean of an arm of articulated robot which develops the movement sequences and the taking a decision based on the information coming from the external sensors. (Author)

  4. Smooth leader or sharp follower? Playing the mirror game with a robot.

    Science.gov (United States)

    Kashi, Shir; Levy-Tzedek, Shelly

    2018-01-01

    The increasing number of opportunities for human-robot interactions in various settings, from industry through home use to rehabilitation, creates a need to understand how to best personalize human-robot interactions to fit both the user and the task at hand. In the current experiment, we explored a human-robot collaborative task of joint movement, in the context of an interactive game. We set out to test people's preferences when interacting with a robotic arm, playing a leader-follower imitation game (the mirror game). Twenty two young participants played the mirror game with the robotic arm, where one player (person or robot) followed the movements of the other. Each partner (person and robot) was leading part of the time, and following part of the time. When the robotic arm was leading the joint movement, it performed movements that were either sharp or smooth, which participants were later asked to rate. The greatest preference was given to smooth movements. Half of the participants preferred to lead, and half preferred to follow. Importantly, we found that the movements of the robotic arm primed the subsequent movements performed by the participants. The priming effect by the robot on the movements of the human should be considered when designing interactions with robots. Our results demonstrate individual differences in preferences regarding the role of the human and the joint motion path of the robot and the human when performing the mirror game collaborative task, and highlight the importance of personalized human-robot interactions.

  5. Robotics in Arthroplasty: A Comprehensive Review.

    Science.gov (United States)

    Jacofsky, David J; Allen, Mark

    2016-10-01

    Robotic-assisted orthopedic surgery has been available clinically in some form for over 2 decades, claiming to improve total joint arthroplasty by enhancing the surgeon's ability to reproduce alignment and therefore better restore normal kinematics. Various current systems include a robotic arm, robotic-guided cutting jigs, and robotic milling systems with a diversity of different navigation strategies using active, semiactive, or passive control systems. Semiactive systems have become dominant, providing a haptic window through which the surgeon is able to consistently prepare an arthroplasty based on preoperative planning. A review of previous designs and clinical studies demonstrate that these robotic systems decrease variability and increase precision, primarily focusing on component positioning and alignment. Some early clinical results indicate decreased revision rates and improved patient satisfaction with robotic-assisted arthroplasty. The future design objectives include precise planning and even further improved consistent intraoperative execution. Despite this cautious optimism, many still wonder whether robotics will ultimately increase cost and operative time without objectively improving outcomes. Over the long term, every industry that has seen robotic technology be introduced, ultimately has shown an increase in production capacity, improved accuracy and precision, and lower cost. A new generation of robotic systems is now being introduced into the arthroplasty arena, and early results with unicompartmental knee arthroplasty and total hip arthroplasty have demonstrated improved accuracy of placement, improved satisfaction, and reduced complications. Further studies are needed to confirm the cost effectiveness of these technologies. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Bringing robotics technology down to Earth

    International Nuclear Information System (INIS)

    Fuller, B.R.

    1997-01-01

    Robotics technology is successfully being transitioned from space to terrestrial applications. It is being modified and enhanced to help in the US DOE's Environmental Restoration and Waste Management Program. Some examples of these applications, ranging from large multijointed manipulators to autonomously navigated remote vehicles, are outlined in this article. They include the following: underground storage tank technology demonstration; light-duty utility arm system; remotely controlled material-handling system; remotely operated excavator; self-guided transfer vehicle. 10 figs

  7. Robotic neurorehabilitation system design for stroke patients

    Directory of Open Access Journals (Sweden)

    Baoguo Xu

    2015-03-01

    Full Text Available In this article, a neurorehabilitation system combining robot-aided rehabilitation with motor imagery–based brain–computer interface is presented. Feature extraction and classification algorithm for the motor imagery electroencephalography is implemented under our brain–computer interface research platform. The main hardware platform for functional recovery therapy is the Barrett Whole-Arm Manipulator. The mental imagination of upper limb movements is translated to trigger the Barrett Whole-Arm Manipulator Arm to stretch the affected upper limb to move along the predefined trajectory. A fuzzy proportional–derivative position controller is proposed to control the Whole-Arm Manipulator Arm to perform passive rehabilitation training effectively. A preliminary experiment aimed at testing the proposed system and gaining insight into the potential of motor imagery electroencephalography-triggered robotic therapy is reported.

  8. [Robotic assistance in gynaecological surgery: State-of-the-art].

    Science.gov (United States)

    Monsarrat, N; Collinet, P; Narducci, F; Leblanc, E; Vinatier, D

    2009-05-01

    From the Automated Endoscopic System for Optimal Positioning (AESOP), a robotic arm which operates the laparoscope, to the robots Zeus and da Vinci, robotic assistance in gynaecological endoscopic surgery has continuously evolved for the last fifteen years or so. It has brought about new technical advancements: the last generation robots offer a steady three-dimensional image, improved instrument dexterity and precision, higher ergonomics and comfort for the surgeon. The da Vinci robotic system has been used without evincing any specific morbidity in various cases, notably for tubal reanastomosis, myomectomy, hysterectomy, pelvic and para-aortic lymphadenectomy or sacrocolpopexy amongst others. Robotic assistance in gynaecology is thus feasible. Like conventional laparoscopic surgery, it allows decreased blood loss and morbidity as well as shorter hospital stay, as compared to laparotomy. It might indeed allow many surgical teams to perform minimally invasive surgical procedures which they were not used to performing by laparoscopy. Randomized prospective studies are needed to define its indications more precisely. Besides, its medico-financial impact should be evaluated too.

  9. Is the bipolar vessel sealer device an effective tool in robotic surgery? A retrospective analysis of our experience and a meta-analysis of the literature about different robotic procedures by investigating operative data and post-operative course.

    Science.gov (United States)

    Ortenzi, Monica; Ghiselli, Roberto; Baldarelli, Maddalena; Cardinali, Luca; Guerrieri, Mario

    2018-04-01

    The latest robotic bipolar vessel sealing tools have been described to be effective allowing to perform procedures with reduced blood loss and shorter operative times. The aim of this study was to assess the efficacy and reliability of these devices applied in different robotic procedures. All robotic operations, between 2014 and 2016, were performed using the EndoWrist One VesselSealer (EWO, Intuitive Surgical, Sunnyvale, CA), a bipolar fully wristed device. Data, including age, gender, body mass index (BMI), were collected. Robot docking time, intraoperative blood loss, robot malfunctioning and overall operative time were analyzed. A meta-analysis of the literature was carried out to point the attention to three different parameters (mean blood loss, operating time and hospital stay) trying to identify how different coagulation devices may affect them. In 73 robotic procedures, the mean operative time was 118.2 minutes (75-125 minutes). Mean hospital stay was four days (2-10 days). There were two post-operative complications (2.74%). The bipolar vessel sealer offers the efficacy of bipolar diathermy and the advantages of a fully wristed instrument. It does not require any change of instruments for coagulation or involvement of the bedside assistant surgeon. These characteristics lead to a reduction in operative time.

  10. Modeling and Design of an Electro-Rheological Fluid Based Haptic System for Tele-Operation of Space Robots

    Science.gov (United States)

    Mavroidis, Constantinos; Pfeiffer, Charles; Paljic, Alex; Celestino, James; Lennon, Jamie; Bar-Cohen, Yoseph

    2000-01-01

    For many years, the robotic community sought to develop robots that can eventually operate autonomously and eliminate the need for human operators. However, there is an increasing realization that there are some tasks that human can perform significantly better but, due to associated hazards, distance, physical limitations and other causes, only robot can be employed to perform these tasks. Remotely performing these types of tasks requires operating robots as human surrogates. While current "hand master" haptic systems are able to reproduce the feeling of rigid objects, they present great difficulties in emulating the feeling of remote/virtual stiffness. In addition, they tend to be heavy, cumbersome and usually they only allow limited operator workspace. In this paper a novel haptic interface is presented to enable human-operators to "feel" and intuitively mirror the stiffness/forces at remote/virtual sites enabling control of robots as human-surrogates. This haptic interface is intended to provide human operators intuitive feeling of the stiffness and forces at remote or virtual sites in support of space robots performing dexterous manipulation tasks (such as operating a wrench or a drill). Remote applications are referred to the control of actual robots whereas virtual applications are referred to simulated operations. The developed haptic interface will be applicable to IVA operated robotic EVA tasks to enhance human performance, extend crew capability and assure crew safety. The electrically controlled stiffness is obtained using constrained ElectroRheological Fluids (ERF), which changes its viscosity under electrical stimulation. Forces applied at the robot end-effector due to a compliant environment will be reflected to the user using this ERF device where a change in the system viscosity will occur proportionally to the force to be transmitted. In this paper, we will present the results of our modeling, simulation, and initial testing of such an

  11. Ping-Pong Robotics with High-Speed Vision System

    DEFF Research Database (Denmark)

    Li, Hailing; Wu, Haiyan; Lou, Lei

    2012-01-01

    The performance of vision-based control is usually limited by the low sampling rate of the visual feedback. We address Ping-Pong robotics as a widely studied example which requires high-speed vision for highly dynamic motion control. In order to detect a flying ball accurately and robustly...... of the manipulator are updated iteratively with decreasing error. Experiments are conducted on a 7 degrees of freedom humanoid robot arm. A successful Ping-Pong playing between the robot arm and human is achieved with a high successful rate of 88%....

  12. Safety culture in the gynecology robotics operating room.

    Science.gov (United States)

    Zullo, Melissa D; McCarroll, Michele L; Mendise, Thomas M; Ferris, Edward F; Roulette, G D; Zolton, Jessica; Andrews, Stephen J; von Gruenigen, Vivian E

    2014-01-01

    To measure the safety culture in the robotics surgery operating room before and after implementation of the Robotic Operating Room Computerized Checklist (RORCC). Prospective study. Gynecology surgical staff (n = 32). An urban community hospital. The Safety Attitudes Questionnaire domains examined were teamwork, safety, job satisfaction, stress recognition, perceptions of management, and working conditions. Questions and domains were described using percent agreement and the Cronbach alpha. Paired t-tests were used to describe differences before and after implementation of the checklist. Mean (SD) staff age was 46.7 (9.5) years, and most were women (78%) and worked full-time (97%). Twenty respondents (83% of nurses, 80% of surgeons, 66% of surgical technicians, and 33% of certified registered nurse anesthetists) completed the Safety Attitudes Questionnaire; 6 were excluded because of non-matching identifiers. Before RORCC implementation, the highest quality of communication and collaboration was reported by surgeons and surgical technicians (100%). Certified registered nurse anesthetists reported only adequate levels of communication and collaboration with other positions. Most staff reported positive responses for teamwork (48%; α = 0.81), safety (47%; α = 0.75), working conditions (37%; α = 0.55), stress recognition (26%; α = 0.71), and perceptions of management (32%; α = 0.52). No differences were observed after RORCC implementation. Quality of communication and collaboration in the gynecology robotics operating room is high between most positions; however, safety attitude responses are low overall. No differences after RORCC implementation and low response rates may highlight lack of staff support. Copyright © 2014. Published by Elsevier Inc.

  13. Robotic Assisted Transanal Polypectomies: Is There Any Indication?

    Science.gov (United States)

    Gómez Ruiz, Marcos; Cagigas Fernández, Carmen; Alonso Martín, Joaquín; Cristobal Poch, Lidia; Manuel Palazuelos, Carlos; Barredo Cañibano, Francisco Javier; Gómez Fleitas, Manuel; Castillo Diego, Julio

    2017-12-01

    Robotic assisted transanal polipectomy may have advantages compared with the conventional transanal minimally invasive surgery technique. We evaluate the safety, feasibility and advantages of this technique. Between February 2014 and October 2015, 9patients underwent robotic transanal polypectomy. We performed a retrospective study in which we analyse prospectively collected data regarding patient and tumor characteristics, perioperative outcomes, pathological report, morbidity and mortality. A total of 5 male and 4 female patients underwent robotic TAMIS. Lesions were 6,22cm from the anal verge. Mean size was 15,8cm 2 . All procedures were performed in the lithotomy position. Closure of the defect was performed in all cases. Mean blood loss was 39,8ml. Mean operative time was 71,9min. No severe postoperative complications or readmissions occured. Median hospital stay was 2,5 days. Robotic TAMIS is useful to treat complex rectal lesions. Our transanal platform allowed a wider range of movements of the robotic arms and to perform all procedures in the lithotomy position. Copyright © 2017 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Surface Support Systems for Co-Operative and Integrated Human/Robotic Lunar Exploration

    Science.gov (United States)

    Mueller, Robert P.

    2006-01-01

    Human and robotic partnerships to realize space goals can enhance space missions and provide increases in human productivity while decreasing the hazards that the humans are exposed to. For lunar exploration, the harsh environment of the moon and the repetitive nature of the tasks involved with lunar outpost construction, maintenance and operation as well as production tasks associated with in-situ resource utilization, make it highly desirable to use robotic systems in co-operation with human activity. A human lunar outpost is functionally examined and concepts for selected human/robotic tasks are discussed in the context of a lunar outpost which will enable the presence of humans on the moon for extended periods of time.

  15. 6-REXOS: Upper Limb Exoskeleton Robot with Improved pHRI

    Directory of Open Access Journals (Sweden)

    Malin Gunasekara

    2015-04-01

    Full Text Available Close interaction can be observed between an exoskeleton robot and its wearer. Therefore, appropriate physical human-robot interaction (pHRI should be considered when designing an exoskeleton robot to provide safe and comfortable motion assistance. Different features have been used in recent studies to enhance the pHRI in upper-limb exoskeleton robots. However, less attention has been given to integrating kinematic redundancy into upper-limb exoskeleton robots to improve the pHRI. In this context, this paper proposes a six-degrees-of-freedom (DoF upper-limb exoskeleton robot (6-REXOS for the motion assistance of physically weak individuals. The 6-REXOS uses a kinematically different structure to that of the human lower arm, where the exoskeleton robot is worn. The 6-REXOS has four active DoFs to generate the motion of the human lower arm. Furthermore, two flexible bellow couplings are attached to the wrist and elbow joints to generate two passive DoFs. These couplings not only allow translational motion in wrist and elbow joints but also a redundancy in the robot. Furthermore, the compliance of the flexible coupling contributes to avoiding misalignments between human and robot joint axes. The redundancy in the 6-REXOS is verified based on manipulability index, minimum singular value, condition number and manipulability ellipsoids. The 6-REXOS and a four-DoF exoskeleton robot are compared to verify the manipulation advantage due to the redundancy. The four-DoF exoskeleton robot is designed by excluding the two passive DoFs of the 6-REXOS. In addition, a kinematic model is proposed for the human lower arm to validate the performance of the 6-REXOS. Kinematic analysis and simulations are carried out to validate the 6-REXOS and human-lower-arm model.

  16. A numerical investigation of flow around octopus-like arms: near-wake vortex patterns and force development.

    Science.gov (United States)

    Kazakidi, A; Vavourakis, V; Tsakiris, D P; Ekaterinaris, J A

    2015-01-01

    The fluid dynamics of cephalopods has so far received little attention in the literature, due to their complexity in structure and locomotion. The flow around octopuses, in particular, can be complicated due to their agile and dexterous arms, which frequently display some of the most diverse mechanisms of motion. The study of this flow amounts to a specific instance of the hydrodynamics problem for rough tapered cylinder geometries. The outstanding manipulative and locomotor skills of octopuses could inspire the development of advanced robotic arms, able to operate in fluid environments. Our primary aim was to study the hydrodynamic characteristics of such bio-inspired robotic models and to derive the hydrodynamic force coefficients as a concise description of the vortical flow effects. Utilizing computational fluid dynamic methods, the coefficients were computed on realistic morphologies of octopus-like arm models undergoing prescribed solid-body movements; such motions occur in nature for short durations in time, e.g. during reaching movements and exploratory behaviors. Numerical simulations were performed on translating, impulsively rotating, and maneuvering arms, around which the flow field structures were investigated. The results reveal in detail the generation of complex vortical flow structures around the moving arms. Hydrodynamic forces acting on a translating arm depend on the angle of incidence; forces generated during impulsive rotations of the arms are independent of their exact morphology and the angle of rotation; periodic motions based on a slow recovery and a fast power stroke are able to produce considerable propulsive thrust while harmonic motions are not. Parts of these results have been employed in bio-inspired models of underwater robotic mechanisms. This investigation may further assist elucidating the hydrodynamics underlying aspects of octopus locomotion and exploratory behaviors.

  17. SAFIRE - a robotic inspection system for CANDU feeders

    Energy Technology Data Exchange (ETDEWEB)

    Buckingham, R. [OC Robotics, Bristol (United Kingdom)

    2011-07-01

    The condition of primary circuit feeder pipes in CANDU reactors is relevant to the commercial viability and plant life. One known wear mechanism is external fretting between feeder pipes and adjacent services or support structures, particularly within the Upper Feeder Cabinet (UFC). Fretting leads to wall thinning which must not exceed certain agreed limits. Chafe shields have been added to protect the feeder pipes. Regular inspections are required of the chafe shields, feeder pipes and other structures that may cause feeder damage. Historically, the dose received by inspectors conducting this work has been significant. For this reason Ontario Power Generation has invested in a remotely operated robot system to conduct visual inspections within the UFC. This system, called SAFIRE for 'Snake-Arm Feeder Inspection Robot Equipment' has been deployed at Pickering during 2010 and 2011 and has been used to inspect areas that are extremely difficult to inspect with existing manual techniques. The 2011 scope of work included inspection of a total of 660 feeder pipes in three UFC quadrants, in two reactors. The full scope was completed over a one-month period in Autumn 2011 in which SAFIRE was used during 23, twelve hour shifts. This included two periods each of 72 hours of continuous operation using multiple teams of operators. SAFIRE is remote controlled delivery system for multiple cameras to record still images and video. The main system elements include a snake-arm robot mounted on a mobile vehicle. It can be controlled from up to 500m away using a fibre/copper connection. The snake-arm is 2.2m long, 25mm wide and has 18 degrees of freedom. It is designed to snake between the rows of feeder pipes to inspect feeder/hanger interfaces, both above and below the feeder cabinet catwalks. Future upgrades offer the potential to add additional tools to increase functionality. This paper describes the SAFIRE development process from inception to operational experience

  18. SAFIRE - a robotic inspection system for CANDU feeders

    International Nuclear Information System (INIS)

    Buckingham, R.

    2011-01-01

    The condition of primary circuit feeder pipes in CANDU reactors is relevant to the commercial viability and plant life. One known wear mechanism is external fretting between feeder pipes and adjacent services or support structures, particularly within the Upper Feeder Cabinet (UFC). Fretting leads to wall thinning which must not exceed certain agreed limits. Chafe shields have been added to protect the feeder pipes. Regular inspections are required of the chafe shields, feeder pipes and other structures that may cause feeder damage. Historically, the dose received by inspectors conducting this work has been significant. For this reason Ontario Power Generation has invested in a remotely operated robot system to conduct visual inspections within the UFC. This system, called SAFIRE for 'Snake-Arm Feeder Inspection Robot Equipment' has been deployed at Pickering during 2010 and 2011 and has been used to inspect areas that are extremely difficult to inspect with existing manual techniques. The 2011 scope of work included inspection of a total of 660 feeder pipes in three UFC quadrants, in two reactors. The full scope was completed over a one-month period in Autumn 2011 in which SAFIRE was used during 23, twelve hour shifts. This included two periods each of 72 hours of continuous operation using multiple teams of operators. SAFIRE is remote controlled delivery system for multiple cameras to record still images and video. The main system elements include a snake-arm robot mounted on a mobile vehicle. It can be controlled from up to 500m away using a fibre/copper connection. The snake-arm is 2.2m long, 25mm wide and has 18 degrees of freedom. It is designed to snake between the rows of feeder pipes to inspect feeder/hanger interfaces, both above and below the feeder cabinet catwalks. Future upgrades offer the potential to add additional tools to increase functionality. This paper describes the SAFIRE development process from inception to operational experience gained

  19. Operating gains achieved by a new generation of remotely controlled manipulators

    International Nuclear Information System (INIS)

    Djedidi, A.; Selliez-Vandernotte, C.; Malcolm, F.

    2014-01-01

    A high performance remotely controlled mechanical master slave arm with direct transmission via cable and transmission rods has been converted to a new generation manipulator with electrical master slave arm and motion module with integrated software. The redesigned powered manipulator with software control improves efficiency and ergonomics while increasing operating field space. The mechanical master arm has been replaced by an electrical robotic master arm using haptic technology. The movements initiated by the operator are transmitted in real time to the slave arm via the servo-motors inside the motion module. The mechanical link between master and slave is eliminated and some mechanical constraints have been replaced by software applications. The operator benefits from an improved working position and vibration filtering plus full range high performance force feedback with reduced effort requirement. (authors)

  20. Use of the Modified Light Duty Utility Arm to Perform Nuclear Waste Cleanup of Underground Waste Storage Tanks at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Blank, J.A.; Burks, B.L.; DePew, R.E.; Falter, D.D.; Glassell, R.L.; Glover, W.H.; Killough, S.M.; Lloyd, P.D.; Love, L.J.; Randolph, J.D.; Van Hoesen, S.D.; Vesco, D.P.

    1999-01-01

    The Modified Light Duty Utility Arm (MLDUA) is a selectable seven or eight degree-of-freedom robot arm with a 16.5 ft (5.03 m) reach and a payload capacity of 200 lb. (90.72 kg). The utility arm is controlled in either joystick-based telerobotic mode or auto sequence robotics mode. The MLDUA deployment system deploys the utility arm vertically into underground radioactive waste storage tanks located at Oak Ridge National Laboratory. These tanks are constructed of gunite material and consist of two 25 ft (7.62 m) diameter tanks in the North Tank Farm and six 50 ft (15.24 m) diameter tanks in the South Tank Farm. After deployment inside a tank, the utility arm reaches and grasps the confined sluicing end effecter (CSEE) which is attached to the hose management arm (HMA). The utility arm positions the CSEE within the tank to allow the HMA to sluice the tank's liquid and solid waste from the tank. The MLDUA is used to deploy the characterization end effecter (CEE) and gunite scarifying end effecter (GSEE) into the tank. The CEE is used to survey the tank wall's radiation levels and the physical condition of the walls. The GSEE is used to scarify the tank walls with high-pressure water to remove the wall scale buildup and a thin layer of gunite which reduces the radioactive contamination that is embedded into the gunite walls. The MLDUA is also used to support waste sampling and wall core-sampling operations. Other tools that have been developed for use by the MLDUA include a pipe-plugging end effecter, pipe-cutting end effecter, and pipe-cleaning end effecter. Washington University developed advance robotics path control algorithms for use in the tanks. The MLDUA was first deployed in June 1997 and has operated continuously since then. Operational experience in the first four tanks remediated is presented in this paper

  1. An octopus-bioinspired solution to movement and manipulation for soft robots

    Energy Technology Data Exchange (ETDEWEB)

    Calisti, M; Giorelli, M; Laschi, C; Dario, P [BioRobotics Institute, Scuola Superiore Sant' Anna, Pisa (Italy); Levy, G; Hochner, B [Hebrew University of Jerusalem, Jerusalem (Israel); Mazzolai, B, E-mail: marcello.calisti@sssup.it, E-mail: michele.giorelli@sssup.it, E-mail: guy.levy@mail.huji.ac.il, E-mail: barbara.mazzolai@iit.it, E-mail: Binyamin.Hochner@huji.ac.il, E-mail: cecilia.laschi@sssup.it, E-mail: paolo.dario@sssup.it [Centre for Micro-BioRobotics-SSSA, Istituto Italiano di Tecnologia, Pontedera (Italy)

    2011-09-15

    Soft robotics is a challenging and promising branch of robotics. It can drive significant improvements across various fields of traditional robotics, and contribute solutions to basic problems such as locomotion and manipulation in unstructured environments. A challenging task for soft robotics is to build and control soft robots able to exert effective forces. In recent years, biology has inspired several solutions to such complex problems. This study aims at investigating the smart solution that the Octopus vulgaris adopts to perform a crawling movement, with the same limbs used for grasping and manipulation. An ad hoc robot was designed and built taking as a reference a biological hypothesis on crawling. A silicone arm with cables embedded to replicate the functionality of the arm muscles of the octopus was built. This novel arm is capable of pushing-based locomotion and object grasping, mimicking the movements that octopuses adopt when crawling. The results support the biological observations and clearly show a suitable way to build a more complex soft robot that, with minimum control, can perform diverse tasks.

  2. An octopus-bioinspired solution to movement and manipulation for soft robots

    International Nuclear Information System (INIS)

    Calisti, M; Giorelli, M; Laschi, C; Dario, P; Levy, G; Hochner, B; Mazzolai, B

    2011-01-01

    Soft robotics is a challenging and promising branch of robotics. It can drive significant improvements across various fields of traditional robotics, and contribute solutions to basic problems such as locomotion and manipulation in unstructured environments. A challenging task for soft robotics is to build and control soft robots able to exert effective forces. In recent years, biology has inspired several solutions to such complex problems. This study aims at investigating the smart solution that the Octopus vulgaris adopts to perform a crawling movement, with the same limbs used for grasping and manipulation. An ad hoc robot was designed and built taking as a reference a biological hypothesis on crawling. A silicone arm with cables embedded to replicate the functionality of the arm muscles of the octopus was built. This novel arm is capable of pushing-based locomotion and object grasping, mimicking the movements that octopuses adopt when crawling. The results support the biological observations and clearly show a suitable way to build a more complex soft robot that, with minimum control, can perform diverse tasks.

  3. An octopus-bioinspired solution to movement and manipulation for soft robots.

    Science.gov (United States)

    Calisti, M; Giorelli, M; Levy, G; Mazzolai, B; Hochner, B; Laschi, C; Dario, P

    2011-09-01

    Soft robotics is a challenging and promising branch of robotics. It can drive significant improvements across various fields of traditional robotics, and contribute solutions to basic problems such as locomotion and manipulation in unstructured environments. A challenging task for soft robotics is to build and control soft robots able to exert effective forces. In recent years, biology has inspired several solutions to such complex problems. This study aims at investigating the smart solution that the Octopus vulgaris adopts to perform a crawling movement, with the same limbs used for grasping and manipulation. An ad hoc robot was designed and built taking as a reference a biological hypothesis on crawling. A silicone arm with cables embedded to replicate the functionality of the arm muscles of the octopus was built. This novel arm is capable of pushing-based locomotion and object grasping, mimicking the movements that octopuses adopt when crawling. The results support the biological observations and clearly show a suitable way to build a more complex soft robot that, with minimum control, can perform diverse tasks.

  4. Acquisition of Human Operation Characteristics for Kite-based Tethered Flying Robot using Human Operation Data

    OpenAIRE

    Todoroki, Chiaki; Takahashi, Yasutake; Nakamura, Takayuki

    2015-01-01

    This paper shows human skill acquisition systems to control the kite-based tethered flying robot. The kite-based tethered flying robot has been proposed as a flying observation system with long-term activity capability[1]. It is a relatively new system and aimed to complement other information gathering systems using a balloon or an air vehicle. This paper shows some approaches of human operation characteristics acquisition based on fuzzy learning controller, knearest neighbor algorithm, and ...

  5. How to prepare the patient for robotic surgery: before and during the operation.

    Science.gov (United States)

    Lim, Peter C; Kang, Elizabeth

    2017-11-01

    Robotic surgery in the treatment of gynecologic diseases continues to evolve and has become accepted over the last decade. The advantages of robotic-assisted laparoscopic surgery over conventional laparoscopy are three-dimensional camera vision, superior precision and dexterity with EndoWristed instruments, elimination of operator tremor, and decreased surgeon fatigue. The drawbacks of the technology are bulkiness and lack of tactile feedback. As with other surgical platforms, the limitations of robotic surgery must be understood. Patient selection and the types of surgical procedures that can be performed through the robotic surgical platform are critical to the success of robotic surgery. First, patient selection and the indication for gynecologic disease should be considered. Discussion with the patient regarding the benefits and potential risks of robotic surgery and of complications and alternative treatments is mandatory, followed by patient's signature indicating informed consent. Appropriate preoperative evaluation-including laboratory and imaging tests-and bowel cleansing should be considered depending upon the type of robotic-assisted procedure. Unlike other surgical procedures, robotic surgery is equipment-intensive and requires an appropriate surgical suite to accommodate the patient side cart, the vision system, and the surgeon's console. Surgical personnel must be properly trained with the robotics technology. Several factors must be considered to perform a successful robotic-assisted surgery: the indication and type of surgical procedure, the surgical platform, patient position and the degree of Trendelenburg, proper port placement configuration, and appropriate instrumentation. These factors that must be considered so that patients can be appropriately prepared before and during the operation are described. Copyright © 2017. Published by Elsevier Ltd.

  6. Fiscal 2000 report on result of R and D on robot system cooperating and coexisting with human beings. R and D on robot system cooperating and coexisting with human beings; 2000 nendo ningen kyocho kyozongata robot system kenkyu kaihatsu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-06-01

    A highly safe and reliable robot is being developed capable of cooperating with human beings and executing complicated operations in a human working/living space. This paper describes the fiscal 2000 results. Development of robot motion library was continued for extended task for providing services to people in care houses for the aged controlling motions of the humanoid robot. A basic design for a personal service system by the humanoid robot was conducted with the aim of nursing assistance and for the objective of developing a portable terminal type tele-operation device. A public and a home cockpit were researched with the purpose of developing user interfaces for telexistence control. A dynamic simulator for humanoid robots was built, with motions of standing-up and walking examined, in order to develop basic theories for the dual-handed tasks aided by the leg-arm cooperative motion. To develop a robot that properly and safely cooperates and coexists with the human beings, it is essential to obtain a dynamically reasonable and natural control law, so that the basic studies were conducted in this direction. With the purpose of developing a motion capture and learning system, a virtual robot platform and an information acquiring interface were developed. Studies were also conducted on modeling technique for achieving realistic material properties from high-precision image synthesis and actual images. (NEDO)

  7. Development and human factors analysis of an augmented reality interface for multi-robot tele-operation and control

    Science.gov (United States)

    Lee, Sam; Lucas, Nathan P.; Ellis, R. Darin; Pandya, Abhilash

    2012-06-01

    This paper presents a seamlessly controlled human multi-robot system comprised of ground and aerial robots of semiautonomous nature for source localization tasks. The system combines augmented reality interfaces capabilities with human supervisor's ability to control multiple robots. The role of this human multi-robot interface is to allow an operator to control groups of heterogeneous robots in real time in a collaborative manner. It used advanced path planning algorithms to ensure obstacles are avoided and that the operators are free for higher-level tasks. Each robot knows the environment and obstacles and can automatically generate a collision-free path to any user-selected target. It displayed sensor information from each individual robot directly on the robot in the video view. In addition, a sensor data fused AR view is displayed which helped the users pin point source information or help the operator with the goals of the mission. The paper studies a preliminary Human Factors evaluation of this system in which several interface conditions are tested for source detection tasks. Results show that the novel Augmented Reality multi-robot control (Point-and-Go and Path Planning) reduced mission completion times compared to the traditional joystick control for target detection missions. Usability tests and operator workload analysis are also investigated.

  8. Robot arm based flat panel CT-guided electromagnetic tracked spine interventions: phantom and animal model experiments

    International Nuclear Information System (INIS)

    Penzkofer, Tobias; Isfort, Peter; Bruners, Philipp; Mahnken, Andreas H.; Wiemann, Christian; Guenther, Rolf W.; Kyriakou, Yiannis; Kalender, Willi A.; Schmitz-Rode, Thomas

    2010-01-01

    To evaluate accuracy and procedure times of electromagnetic tracking (EMT) in a robotic arm mounted flat panel setting using phantom and animal cadaveric models. A robotic arm mounted flat panel (RMFP) was used in combination with EMT to perform anthropomorphic phantom (n = 90) and ex vivo pig based punctures (n = 120) of lumbar facet joints (FJ, n = 120) and intervertebral discs (IVD, n = 90). Procedure accuracies and times were assessed and evaluated. FJ punctures were carried out with a spatial accuracy of 0.8 ± 0.9 mm (phantom) and 0.6 ± 0.8 mm (ex vivo) respectively. While IVD punctures showed puncture deviations of 0.6 ± 1.2 mm (phantom) and 0.5 ± 0.6 mm (ex vivo), direct and angulated phantom based punctures had accuracies of 0.8 ± 0.9 mm and 1.0 ± 1.3 mm. Planning took longer for ex vivo IVD punctures compared to phantom model interventions (39.3 ± 17.3 s vs. 20.8 ± 5.0 s, p = 0.001) and for angulated vs. direct phantom FJ punctures (19.7 ± 5.1 s vs. 28.6 ± 7.8 s, p < 0.001). Puncture times were longer for ex vivo procedures when compared to phantom model procedures in both FJ (37.9 ± 9.0 s vs. 23.6 ± 7.2 s, p = 0.001) and IVD punctures (43.9 ± 16.1 s vs. 31.1 ± 6.4 s, p = 0.026). The combination of RMFP with EMT provides an accurate method of navigation for spinal interventions such as facet joint punctures and intervertebral disc punctures. (orig.)

  9. The development of robotic systems for hazardous environments

    International Nuclear Information System (INIS)

    Collis-Smith, J.A.; Schilling, R.

    1996-01-01

    The need for teleoperated and robotic systems is growing. This growth is driven by several factors such as - statutory requirements; risk reduction and economic pressures. Robotic Systems are needed to provide reliable, economic means to perform surveillance, quantitative inspection, repairs, upgrading and eventual dismantling for decommissioning tasks. The range of potential applications has widened and there is now significant technical cross-fertilisation between developments in diverse environments. The typical robotic system consists of the emplacement equipment, the dextrous arm, the tool and the controls. The control system provides the operator with an integrated interface between the principal components, so that the operator can concentrate fully at the high level on the specific task in hand, while the control system and its software performs all the detail functions within the subparts of the integrated system. This paper develops this underlying logic, and is illustrated by experience drawn from a variety of examples in different environments to show the present state of the art in GEC Alsthom and suggest the way ahead in the near-term future. (Author)

  10. Does transition from the da Vinci Si to Xi robotic platform impact single-docking technique for robot-assisted laparoscopic nephroureterectomy?

    Science.gov (United States)

    Patel, Manish N; Aboumohamed, Ahmed; Hemal, Ashok

    2015-12-01

    To describe our robot-assisted nephroureterectomy (RNU) technique for benign indications and RNU with en bloc excision of bladder cuff (BCE) and lymphadenectomy (LND) for malignant indications using the da Vinci Si and da Vinci Xi robotic platform, with its pros and cons. The port placement described for Si can be used for standard and S robotic systems. This is the first report in the literature on the use of the da Vinci Xi robotic platform for RNU. After a substantial experience of RNU using different da Vinci robots from the standard to the Si platform in a single-docking fashion for benign and malignant conditions, we started using the newly released da Vinci Xi robot since 2014. The most important differences are in port placement and effective use of the features of da Vinci Xi robot while performing simultaneous upper and lower tract surgery. Patient positioning, port placement, step-by-step technique of single docking RNU-LND-BCE using the da Vinci Si and da Vinci Xi robot are shown in an accompanying video with the goal that centres using either robotic system benefit from the hints and tips. The first segment of video describes RNU-LND-BCE using the da Vinci Si followed by the da Vinci Xi to highlight differences. There was no need for patient repositioning or robot re-docking with the new da Vinci Xi robotic platform. We have experience of using different robotic systems for single docking RNU in 70 cases for benign (15) and malignant (55) conditions. The da Vinci Xi robotic platform helps operating room personnel in its easy movement, allows easier patient side-docking with the help of its boom feature, in addition to easy and swift movements of the robotic arms. The patient clearance feature can be used to avoid collision with the robotic arms or the patient's body. In patients with challenging body habitus and in situations where bladder cuff management is difficult, modifications can be made through reassigning the camera to a different port with

  11. FY 1999 achievement report on the R and D of a human cooperation/coexistence robot system. New development for the commercialization for the electric power generation technology; 1999 nendo ningen kyocho kyozongata robot system kenkyu kaihatsu seika hokokusho. Shinhatsuden gijutsu jitsuyoka kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    The paper described the FY 1999 results of the development of a human cooperation/coexistence robot system and the development for commercialization for power plants. The support robot platform for maintenance, etc. was fabricated, connected with the remote operation system and verified of the integrated function. The operator controls the robot from the remote operation cockpit by HMD (head mounted display) which can present image following the head movement of the operator, extended virtual reality technology, and stereo-sound system. Hand/arm movement and instruction for movement were given to the robot, and at the same time, the robot was made a device which can present inner force sense and bodily sensation to the operator. The remote hand operating software was developed. A method was developed by which the information on visual sense, touch sense and somatic sense is presented in realtime to the operator so that he can obtain a feeling of attendance. A model for sensor simulator verification was also developed so that the developer of software can also make a verification experiment in the actual environment. Interface was developed so that library of basic movements can be used in the network environment. An investigational research on the promotion of robot was made. (NEDO)

  12. Fuzzy Control of Robotic Arm

    Science.gov (United States)

    Lin, Kyaw Kyaw; Soe, Aung Kyaw; Thu, Theint Theint

    2008-10-01

    This research work investigates a Self-Tuning Proportional Derivative (PD) type Fuzzy Logic Controller (STPDFLC) for a two link robot system. The proposed scheme adjusts on-line the output Scaling Factor (SF) by fuzzy rules according to the current trend of the robot. The rule base for tuning the output scaling factor is defined on the error (e) and change in error (de). The scheme is also based on the fact that the controller always tries to manipulate the process input. The rules are in the familiar if-then format. All membership functions for controller inputs (e and de) and controller output (UN) are defined on the common interval [-1,1]; whereas the membership functions for the gain updating factor (α) is defined on [0,1]. There are various methods to calculate the crisp output of the system. Center of Gravity (COG) method is used in this application due to better results it gives. Performances of the proposed STPDFLC are compared with those of their corresponding PD-type conventional Fuzzy Logic Controller (PDFLC). The proposed scheme shows a remarkably improved performance over its conventional counterpart especially under parameters variation (payload). The two-link results of analysis are simulated. These simulation results are illustrated by using MATLAB® programming.

  13. Starting a robotic program in general thoracic surgery: why, how, and lessons learned.

    Science.gov (United States)

    Cerfolio, Robert J; Bryant, Ayesha S; Minnich, Douglas J

    2011-06-01

    We report our experience in starting a robotic program in thoracic surgery. We retrospectively reviewed our experience in starting a robotic program in general thoracic surgery on a consecutive series of patients. Between February 2009 and September 2010, 150 patients underwent robotic operations. Types of procedures were lobectomy in 62, thymectomy in 30, and benign esophageal procedures in 6. No thymectomy or esophageal procedures required conversion. One conversion was needed for suspected bleeding for a mediastinal mass. Twelve patients were converted for lobectomy (none for bleeding, 1 in the last 24). Median operative time for robotic thymectomy was 119 minutes, and median length of stay was 1 day. The median time for robotic lobectomy was 185 minutes, and median length of stay was 2 days. There were no operative deaths. Morbidity occurred in 23 patients (15%). All patients with cancer had R0 resections and resection of all visible mediastinal and hilar lymph nodes. Robotic surgery is safe and oncologically sound. It requires training of the entire operating room team. The learning curve is steep, involving port placement, availability of the proper instrumentation, use of the correct robotic arms, and proper patient positioning. The robot provides an ideal surgical approach for thymectomy and other mediastinal tumors. Its advantage over thoracoscopy for pulmonary resection is unproven; however, we believe complete thoracic lymph node dissection and teaching is easier. Importantly, defined credentialing for surgeons and cost analysis studies are needed. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Design and implementation of self-balancing coaxial two wheel robot based on HSIC

    Science.gov (United States)

    Hu, Tianlian; Zhang, Hua; Dai, Xin; Xia, Xianfeng; Liu, Ran; Qiu, Bo

    2007-12-01

    This thesis has studied the control problem concerning position and orientation control of self-balancing coaxial two wheel robot based on the human simulated intelligent control (HSIC) theory. Adopting Lagrange equation, the dynamic model of self-balancing coaxial two-wheel Robot is built up, and the Sensory-motor Intelligent Schemas (SMIS) of HSIC controller for the robot is designed by analyzing its movement and simulating the human controller. In robot's motion process, by perceiving position and orientation of the robot and using multi-mode control strategy based on characteristic identification, the HSIC controller enables the robot to control posture. Utilizing Matlab/Simulink, a simulation platform is established and a motion controller is designed and realized based on RT-Linux real-time operating system, employing high speed ARM9 processor S3C2440 as kernel of the motion controller. The effectiveness of the new design is testified by the experiment.

  15. Application of robotics in remote fuel fabrication operations

    International Nuclear Information System (INIS)

    Nyman, D.H.; Nagamoto, T.T.

    1984-01-01

    The Secure Automated Fabrication (SAF) line, an automated and remotely controlled manufacturing process, is scheduled for startup in 1987 and will produce mixed uranium/plutonium oxide fuel pins for the Fast Flux Test Facility (FFTF). The application of robotics in the fuel fabrication and supporting operations is described

  16. Comparison of three-dimensional, assist-as-needed robotic arm/hand movement training provided with Pneu-WREX to conventional tabletop therapy after chronic stroke.

    Science.gov (United States)

    Reinkensmeyer, David J; Wolbrecht, Eric T; Chan, Vicky; Chou, Cathy; Cramer, Steven C; Bobrow, James E

    2012-11-01

    Robot-assisted movement training can help individuals with stroke reduce arm and hand impairment, but robot therapy is typically only about as effective as conventional therapy. Refining the way that robots assist during training may make them more effective than conventional therapy. Here, the authors measured the therapeutic effect of a robot that required individuals with a stroke to achieve virtual tasks in three dimensions against gravity. The robot continuously estimated how much assistance patients needed to perform the tasks and provided slightly less assistance than needed to reduce patient slacking. Individuals with a chronic stroke (n = 26; baseline upper limb Fugl-Meyer score, 23 ± 8) were randomized into two groups and underwent 24 one-hour training sessions over 2 mos. One group received the assist-as-needed robot training and the other received conventional tabletop therapy with the supervision of a physical therapist. Training helped both groups significantly reduce their motor impairment, as measured by the primary outcome measure, the Fugl-Meyer score, but the improvement was small (3.0 ± 4.9 points for robot therapy vs. 0.9 ± 1.7 for conventional therapy). There was a trend for greater reduction for the robot-trained group (P = 0.07). The robot group largely sustained this gain at the 3-mo follow-up. The robot-trained group also experienced significant improvements in Box and Blocks score and hand grip strength, whereas the control group did not, but these improvements were not sustained at follow-up. In addition, the robot-trained group showed a trend toward greater improvement in sensory function, as measured by the Nottingham Sensory Test (P = 0.06). These results suggest that in patients with chronic stroke and moderate-severe deficits, assisting in three-dimensional virtual tasks with an assist-as-needed controller may make robotic training more effective than conventional tabletop training.

  17. The Asteroid Redirect Mission (ARM)

    Science.gov (United States)

    Abell, Paul; Gates, Michele; Johnson, Lindley; Chodas, Paul; Mazanek, Dan; Reeves, David; Ticker, Ronald

    2016-07-01

    To achieve its long-term goal of sending humans to Mars, the National Aeronautics and Space Administration (NASA) plans to proceed in a series of incrementally more complex human spaceflight missions. Today, human flight experience extends only to Low-Earth Orbit (LEO), and should problems arise during a mission, the crew can return to Earth in a matter of minutes to hours. The next logical step for human spaceflight is to gain flight experience in the vicinity of the Moon. These cis-lunar missions provide a "proving ground" for the testing of systems and operations while still accommodating an emergency return path to the Earth that would last only several days. Cis-lunar mission experience will be essential for more ambitious human missions beyond the Earth-Moon system, which will require weeks, months, or even years of transit time. In addition, NASA has been given a Grand Challenge to find all asteroid threats to human populations and know what to do about them. Obtaining knowledge of asteroid physical properties combined with performing technology demonstrations for planetary defense provide much needed information to address the issue of future asteroid impacts on Earth. Hence the combined objectives of human exploration and planetary defense give a rationale for the Asteroid Re-direct Mission (ARM). Mission Description: NASA's ARM consists of two mission segments: 1) the Asteroid Redirect Robotic Mission (ARRM), the first robotic mission to visit a large (greater than ~100 m diameter) near-Earth asteroid (NEA), collect a multi-ton boulder from its surface along with regolith samples, demonstrate a planetary defense technique, and return the asteroidal material to a stable orbit around the Moon; and 2) the Asteroid Redirect Crewed Mission (ARCM), in which astronauts will take the Orion capsule to rendezvous and dock with the robotic vehicle, conduct multiple extravehicular activities to explore the boulder, and return to Earth with samples. NASA's proposed

  18. Development of a remote tank inspection robotic system

    International Nuclear Information System (INIS)

    Knape, B.P.; Bares, L.C.

    1990-01-01

    RedZone Robotics is currently developing a remote tank inspection (RTI) robotic system for Westinghouse Idaho Nuclear Company (WINCO). WINCO intends to use the RTI robotic system at the Idaho Chemical Processing Plant, a facility that contains a tank farm of several 1,135,500-ell (300,000-gal), 15.2-m (50-ft)-diam, high-level liquid waste storage tanks. The primary purpose of the RTI robotic system is to inspect the interior of these tanks for corrosion that may have been caused by the combined effects of radiation, high temperature, and caustic by the combined effects of radiation, high temperature, and caustic chemicals present inside the tanks. The RTI robotic system features a vertical deployment unit, a robotic arm, and a remote control console and computer [located up to 30.5 m (100 ft) away from the tank site]. All actuators are high torque, electric dc brush motors that are servocontrolled with absolute position feedback. The control system uses RedZone's standardized intelligent controller for enhanced telerobotics, which provides a high speed, multitasking environment on a VME bus. Currently, the robot is controlled in a manual, job-button, control mode; however, control capability is available to develop preprogrammed, automated modes of operation

  19. A Cross-Platform Tactile Capabilities Interface for Humanoid Robots

    Directory of Open Access Journals (Sweden)

    Jie eMa

    2016-04-01

    Full Text Available This article presents the core elements of a cross-platform tactile capabilities interface (TCI for humanoid arms. The aim of the interface is to reduce the cost of developing humanoid robot capabilities by supporting reuse through cross-platform deployment. The article presents a comparative analysis of existing robot middleware frameworks, as well as the technical details of the TCI framework that builds on the the existing YARP platform. The TCI framework currently includes robot arm actuators with robot skin sensors. It presents such hardware in a platform independent manner, making it possible to write robot control software that can be executed on different robots through the TCI frameworks. The TCI framework supports multiple humanoid platforms and this article also presents a case study of a cross-platform implementation of a set of tactile protective withdrawal reflexes that have been realised on both the Nao and iCub humanoid robot platforms using the same high-level source code.

  20. Optimization approaches for robot trajectory planning

    Directory of Open Access Journals (Sweden)

    Carlos Llopis-Albert

    2018-03-01

    Full Text Available The development of optimal trajectory planning algorithms for autonomous robots is a key issue in order to efficiently perform the robot tasks. This problem is hampered by the complex environment regarding the kinematics and dynamics of robots with several arms and/or degrees of freedom (dof, the design of collision-free trajectories and the physical limitations of the robots. This paper presents a review about the existing robot motion planning techniques and discusses their pros and cons regarding completeness, optimality, efficiency, accuracy, smoothness, stability, safety and scalability.