  1. Robotic arm

    International Nuclear Information System (INIS)

    Kwech, H.

    1989-01-01

    A robotic arm positionable within a nuclear vessel by access through a small diameter opening and having a mounting tube supported within the vessel and mounting a plurality of arm sections for movement lengthwise of the mounting tube as well as for movement out of a window provided in the wall of the mounting tube is disclosed. An end effector, such as a grinding head or welding element, at an operating end of the robotic arm, can be located and operated within the nuclear vessel through movement derived from six different axes of motion provided by mounting and drive connections between arm sections of the robotic arm. The movements are achieved by operation of remotely-controllable servo motors, all of which are mounted at a control end of the robotic arm to be outside the nuclear vessel. 23 figs

  2. Robotic arm

    Science.gov (United States)

    Kwech, Horst

    1989-04-18

    A robotic arm positionable within a nuclear vessel by access through a small diameter opening and having a mounting tube supported within the vessel and mounting a plurality of arm sections for movement lengthwise of the mounting tube as well as for movement out of a window provided in the wall of the mounting tube. An end effector, such as a grinding head or welding element, at an operating end of the robotic arm, can be located and operated within the nuclear vessel through movement derived from six different axes of motion provided by mounting and drive connections between arm sections of the robotic arm. The movements are achieved by operation of remotely-controllable servo motors, all of which are mounted at a control end of the robotic arm to be outside the nuclear vessel.

  3. Evolution of robotic arms.

    Science.gov (United States)

    Moran, Michael E

    2007-01-01

    The foundation of surgical robotics is in the development of the robotic arm. This is a thorough review of the literature on the nature and development of this device with emphasis on surgical applications. We have reviewed the published literature and classified robotic arms by their application: show, industrial application, medical application, etc. There is a definite trend in the manufacture of robotic arms toward more dextrous devices, more degrees-of-freedom, and capabilities beyond the human arm. da Vinci designed the first sophisticated robotic arm in 1495 with four degrees-of-freedom and an analog on-board controller supplying power and programmability. von Kemplen's chess-playing automaton left arm was quite sophisticated. Unimate introduced the first industrial robotic arm in 1961, it has subsequently evolved into the PUMA arm. In 1963 the Rancho arm was designed; Minsky's Tentacle arm appeared in 1968, Scheinman's Stanford arm in 1969, and MIT's Silver arm in 1974. Aird became the first cyborg human with a robotic arm in 1993. In 2000 Miguel Nicolalis redefined possible man-machine capacity in his work on cerebral implantation in owl-monkeys directly interfacing with robotic arms both locally and at a distance. The robotic arm is the end-effector of robotic systems and currently is the hallmark feature of the da Vinci Surgical System making its entrance into surgical application. But, despite the potential advantages of this computer-controlled master-slave system, robotic arms have definite limitations. Ongoing work in robotics has many potential solutions to the drawbacks of current robotic surgical systems.

  4. Electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength after stroke.

    Science.gov (United States)

    Mehrholz, Jan; Pohl, Marcus; Platz, Thomas; Kugler, Joachim; Elsner, Bernhard

    2015-11-07

    Electromechanical and robot-assisted arm training devices are used in rehabilitation, and may help to improve arm function after stroke. To assess the effectiveness of electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength in people after stroke. We also assessed the acceptability and safety of the therapy. We searched the Cochrane Stroke Group's Trials Register (last searched February 2015), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library 2015, Issue 3), MEDLINE (1950 to March 2015), EMBASE (1980 to March 2015), CINAHL (1982 to March 2015), AMED (1985 to March 2015), SPORTDiscus (1949 to March 2015), PEDro (searched April 2015), Compendex (1972 to March 2015), and Inspec (1969 to March 2015). We also handsearched relevant conference proceedings, searched trials and research registers, checked reference lists, and contacted trialists, experts, and researchers in our field, as well as manufacturers of commercial devices. Randomised controlled trials comparing electromechanical and robot-assisted arm training for recovery of arm function with other rehabilitation or placebo interventions, or no treatment, for people after stroke. Two review authors independently selected trials for inclusion, assessed trial quality and risk of bias, and extracted data. We contacted trialists for additional information. We analysed the results as standardised mean differences (SMDs) for continuous variables and risk differences (RDs) for dichotomous variables. We included 34 trials (involving 1160 participants) in this update of our review. Electromechanical and robot-assisted arm training improved activities of daily living scores (SMD 0.37, 95% confidence interval (CI) 0.11 to 0.64, P = 0.005, I² = 62%), arm function (SMD 0.35, 95% CI 0.18 to 0.51, P arm muscle strength (SMD 0.36, 95% CI 0.01 to 0.70, P = 0.04, I² = 72%), but the quality of the evidence was low to very low

  5. Mobile HTS-SQUID NDE system with robot arm and active shielding using fluxgate

    Energy Technology Data Exchange (ETDEWEB)

    Hatsukade, Y. [Department of Ecological Engineering, Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580 (Japan)], E-mail: hatukade@eco.tut.ac.jp; Yotsugi, K.; Tanaka, S. [Department of Ecological Engineering, Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580 (Japan)

    2008-09-15

    A robot-arm-based mobile HTS-SQUID NDE system was developed for inspection of advanced structures such as hydrogen fuel cell tanks. In order to realize stable operation of HTS-SQUID exposed in Earth's field and robot arm's noise without flux trapping, flux jumping and unlocking during motion, a new active magnetic shielding (AMS) technique using fluxgate was introduced. The high sensitive fluxgate, which could measure magnetic field of up to several 10 {mu}T, was mounted near an HTS-SQUID gradiometer on the robot arm to measure the ambient noise and feed back its output to a compensation coil, which surrounded both SQUID and fluxgate to cancel the ambient noise around them. The AMS technique successfully enabled the HTS-SQUID gradiometer to be moved at 10 mm/s by the robot arm in unshielded environment without flux trapping, jumping and unlocking. Detection of hidden slots in multi-layer composite-metal structures imitating the fuel cell tank was demonstrated.

  6. A reliability study on brain activation during active and passive arm movements supported by an MRI-compatible robot.

    Science.gov (United States)

    Estévez, Natalia; Yu, Ningbo; Brügger, Mike; Villiger, Michael; Hepp-Reymond, Marie-Claude; Riener, Robert; Kollias, Spyros

    2014-11-01

    In neurorehabilitation, longitudinal assessment of arm movement related brain function in patients with motor disability is challenging due to variability in task performance. MRI-compatible robots monitor and control task performance, yielding more reliable evaluation of brain function over time. The main goals of the present study were first to define the brain network activated while performing active and passive elbow movements with an MRI-compatible arm robot (MaRIA) in healthy subjects, and second to test the reproducibility of this activation over time. For the fMRI analysis two models were compared. In model 1 movement onset and duration were included, whereas in model 2 force and range of motion were added to the analysis. Reliability of brain activation was tested with several statistical approaches applied on individual and group activation maps and on summary statistics. The activated network included mainly the primary motor cortex, primary and secondary somatosensory cortex, superior and inferior parietal cortex, medial and lateral premotor regions, and subcortical structures. Reliability analyses revealed robust activation for active movements with both fMRI models and all the statistical methods used. Imposed passive movements also elicited mainly robust brain activation for individual and group activation maps, and reliability was improved by including additional force and range of motion using model 2. These findings demonstrate that the use of robotic devices, such as MaRIA, can be useful to reliably assess arm movement related brain activation in longitudinal studies and may contribute in studies evaluating therapies and brain plasticity following injury in the nervous system.

  7. Robots testing robots: ALAN-Arm, a humanoid arm for the testing of robotic rehabilitation systems.

    Science.gov (United States)

    Brookes, Jack; Kuznecovs, Maksims; Kanakis, Menelaos; Grigals, Arturs; Narvidas, Mazvydas; Gallagher, Justin; Levesley, Martin

    2017-07-01

    Robotics is increasing in popularity as a method of providing rich, personalized and cost-effective physiotherapy to individuals with some degree of upper limb paralysis, such as those who have suffered a stroke. These robotic rehabilitation systems are often high powered, and exoskeletal systems can attach to the person in a restrictive manner. Therefore, ensuring the mechanical safety of these devices before they come in contact with individuals is a priority. Additionally, rehabilitation systems may use novel sensor systems to measure current arm position. Used to capture and assess patient movements, these first need to be verified for accuracy by an external system. We present the ALAN-Arm, a humanoid robotic arm designed to be used for both accuracy benchmarking and safety testing of robotic rehabilitation systems. The system can be attached to a rehabilitation device and then replay generated or human movement trajectories, as well as autonomously play rehabilitation games or activities. Tests of the ALAN-Arm indicated it could recreate the path of a generated slow movement path with a maximum error of 14.2mm (mean = 5.8mm) and perform cyclic movements up to 0.6Hz with low gain (<1.5dB). Replaying human data trajectories showed the ability to largely preserve human movement characteristics with slightly higher path length and lower normalised jerk.

  8. High precision detector robot arm system

    Science.gov (United States)

    Shu, Deming; Chu, Yong

    2017-01-31

    A method and high precision robot arm system are provided, for example, for X-ray nanodiffraction with an X-ray nanoprobe. The robot arm system includes duo-vertical-stages and a kinematic linkage system. A two-dimensional (2D) vertical plane ultra-precision robot arm supporting an X-ray detector provides positioning and manipulating of the X-ray detector. A vertical support for the 2D vertical plane robot arm includes spaced apart rails respectively engaging a first bearing structure and a second bearing structure carried by the 2D vertical plane robot arm.

  9. The MVACS Robotic Arm Camera

    Science.gov (United States)

    Keller, H. U.; Hartwig, H.; Kramm, R.; Koschny, D.; Markiewicz, W. J.; Thomas, N.; Fernades, M.; Smith, P. H.; Reynolds, R.; Lemmon, M. T.; Weinberg, J.; Marcialis, R.; Tanner, R.; Boss, B. J.; Oquest, C.; Paige, D. A.

    2001-08-01

    The Robotic Arm Camera (RAC) is one of the key instruments newly developed for the Mars Volatiles and Climate Surveyor payload of the Mars Polar Lander. This lightweight instrument employs a front lens with variable focus range and takes images at distances from 11 mm (image scale 1:1) to infinity. Color images with a resolution of better than 50 μm can be obtained to characterize the Martian soil. Spectral information of nearby objects is retrieved through illumination with blue, green, and red lamp sets. The design and performance of the camera are described in relation to the science objectives and operation. The RAC uses the same CCD detector array as the Surface Stereo Imager and shares the readout electronics with this camera. The RAC is mounted at the wrist of the Robotic Arm and can characterize the contents of the scoop, the samples of soil fed to the Thermal Evolved Gas Analyzer, the Martian surface in the vicinity of the lander, and the interior of trenches dug out by the Robotic Arm. It can also be used to take panoramic images and to retrieve stereo information with an effective baseline surpassing that of the Surface Stereo Imager by about a factor of 3.

  10. Stress analysis for robot arm version 2

    International Nuclear Information System (INIS)

    Anwar Abdul Rahman; Fikri, A.; Salleh, M. S.; Mohd Arif Hamzah; Azraf Azman; Rosli Darmawan; Mohd Rizal Mamat

    2010-01-01

    The design of a robot needs to be analyzed to ensure the specification and requirement by the user is full filled. Therefore, stress analysis has been performed on the robot arm version 2 after its complete fabrication. This paper discusses the result of the analysis and proposed measures to improve the future design of robot arm. (author)

  11. Two-Armed, Mobile, Sensate Research Robot

    Science.gov (United States)

    Engelberger, J. F.; Roberts, W. Nelson; Ryan, David J.; Silverthorne, Andrew

    2004-01-01

    The Anthropomorphic Robotic Testbed (ART) is an experimental prototype of a partly anthropomorphic, humanoid-size, mobile robot. The basic ART design concept provides for a combination of two-armed coordination, tactility, stereoscopic vision, mobility with navigation and avoidance of obstacles, and natural-language communication, so that the ART could emulate humans in many activities. The ART could be developed into a variety of highly capable robotic assistants for general or specific applications. There is especially great potential for the development of ART-based robots as substitutes for live-in health-care aides for home-bound persons who are aged, infirm, or physically handicapped; these robots could greatly reduce the cost of home health care and extend the term of independent living. The ART is a fully autonomous and untethered system. It includes a mobile base on which is mounted an extensible torso topped by a head, shoulders, and two arms. All subsystems of the ART are powered by a rechargeable, removable battery pack. The mobile base is a differentially- driven, nonholonomic vehicle capable of a speed >1 m/s and can handle a payload >100 kg. The base can be controlled manually, in forward/backward and/or simultaneous rotational motion, by use of a joystick. Alternatively, the motion of the base can be controlled autonomously by an onboard navigational computer. By retraction or extension of the torso, the head height of the ART can be adjusted from 5 ft (1.5 m) to 6 1/2 ft (2 m), so that the arms can reach either the floor or high shelves, or some ceilings. The arms are symmetrical. Each arm (including the wrist) has a total of six rotary axes like those of the human shoulder, elbow, and wrist joints. The arms are actuated by electric motors in combination with brakes and gas-spring assists on the shoulder and elbow joints. The arms are operated under closed-loop digital control. A receptacle for an end effector is mounted on the tip of the wrist and

  12. Continuum robot arms inspired by cephalopods

    Science.gov (United States)

    Walker, Ian D.; Dawson, Darren M.; Flash, Tamar; Grasso, Frank W.; Hanlon, Roger T.; Hochner, Binyamin; Kier, William M.; Pagano, Christopher C.; Rahn, Christopher D.; Zhang, Qiming M.

    2005-05-01

    In this paper, we describe our recent results in the development of a new class of soft, continuous backbone ("continuum") robot manipulators. Our work is strongly motivated by the dexterous appendages found in cephalopods, particularly the arms and suckers of octopus, and the arms and tentacles of squid. Our ongoing investigation of these animals reveals interesting and unexpected functional aspects of their structure and behavior. The arrangement and dynamic operation of muscles and connective tissue observed in the arms of a variety of octopus species motivate the underlying design approach for our soft manipulators. These artificial manipulators feature biomimetic actuators, including artificial muscles based on both electro-active polymers (EAP) and pneumatic (McKibben) muscles. They feature a "clean" continuous backbone design, redundant degrees of freedom, and exhibit significant compliance that provides novel operational capacities during environmental interaction and object manipulation. The unusual compliance and redundant degrees of freedom provide strong potential for application to delicate tasks in cluttered and/or unstructured environments. Our aim is to endow these compliant robotic mechanisms with the diverse and dexterous grasping behavior observed in octopuses. To this end, we are conducting fundamental research into the manipulation tactics, sensory biology, and neural control of octopuses. This work in turn leads to novel approaches to motion planning and operator interfaces for the robots. The paper describes the above efforts, along with the results of our development of a series of continuum tentacle-like robots, demonstrating the unique abilities of biologically-inspired design.

  13. Controlling robot arm with the mind

    National Science Foundation

    2017-05-31

    Full Text Available Research test subjects at the University of Minnesota who were fitted with a specialized noninvasive brain cap were able to move a robotic arm just by imagining moving their own arms.

  14. Picking Robot Arm Trajectory Planning Method

    Directory of Open Access Journals (Sweden)

    Zhang Zhiyong

    2014-01-01

    Full Text Available The picking robot arm is scheduled to complete picking tasks in the working space, to overcome the shaking vibration to improve the picking stability, its movement should follow specific consistence trajectory points. Usually we should give definite multiple feature picking points, map their inverse kinematics to the joint space, establish motion equation for the corresponding point in the joint space, then follow these equations motion for the interpolation on the joint so that we can meet the movement requirements. Trajectory planning is decisive significance for accuracy and stability of controlling robot arm. The key issue that picking arm complete picking task will be come true by trajectory planning, namely, robot arm track the desired trajectory. which based on kinematics and statics picking analysis in a joint space according to the requirements of picking tasks, and obtain the position and orientation for picking robot arm, study and calculate the theory of trajectory parameters timely.

  15. Lending a helping hand: toward novel assistive robotic arms

    NARCIS (Netherlands)

    Groothuis, Stefan; Stramigioli, Stefano; Carloni, Raffaella

    Assistive robotics is an increasingly popular research field, which has led to a large number of commercial and noncommercial systems aimed at assisting physically impaired or elderly users in the activities of daily living. In this article, we propose five criteria based on robotic arm usage

  16. Design of a biomimetic robotic octopus arm.

    Science.gov (United States)

    Laschi, C; Mazzolai, B; Mattoli, V; Cianchetti, M; Dario, P

    2009-03-01

    This paper reports the rationale and design of a robotic arm, as inspired by an octopus arm. The octopus arm shows peculiar features, such as the ability to bend in all directions, to produce fast elongations, and to vary its stiffness. The octopus achieves these unique motor skills, thanks to its peculiar muscular structure, named muscular hydrostat. Different muscles arranged on orthogonal planes generate an antagonistic action on each other in the muscular hydrostat, which does not change its volume during muscle contractions, and allow bending and elongation of the arm and stiffness variation. By drawing inspiration from natural skills of octopus, and by analysing the geometry and mechanics of the muscular structure of its arm, we propose the design of a robot arm consisting of an artificial muscular hydrostat structure, which is completely soft and compliant, but also able to stiffen. In this paper, we discuss the design criteria of the robotic arm and how this design and the special arrangement of its muscular structure may bring the building of a robotic arm into being, by showing the results obtained by mathematical models and prototypical mock-ups.

  17. Design of a biomimetic robotic octopus arm

    Energy Technology Data Exchange (ETDEWEB)

    Laschi, C; Cianchetti, M [Advanced Robotics Technology and Systems Laboratory, Scuola Superiore Sant' Anna, Pisa (Italy); Mazzolai, B; Dario, P [Italian Institute of Technology, Genova (Italy); Mattoli, V [Centre of Research in Microengineering Laboratory, Scuola Superiore Sant' Anna, Pisa (Italy)], E-mail: cecilia.laschi@sssup.it

    2009-03-01

    This paper reports the rationale and design of a robotic arm, as inspired by an octopus arm. The octopus arm shows peculiar features, such as the ability to bend in all directions, to produce fast elongations, and to vary its stiffness. The octopus achieves these unique motor skills, thanks to its peculiar muscular structure, named muscular hydrostat. Different muscles arranged on orthogonal planes generate an antagonistic action on each other in the muscular hydrostat, which does not change its volume during muscle contractions, and allow bending and elongation of the arm and stiffness variation. By drawing inspiration from natural skills of octopus, and by analysing the geometry and mechanics of the muscular structure of its arm, we propose the design of a robot arm consisting of an artificial muscular hydrostat structure, which is completely soft and compliant, but also able to stiffen. In this paper, we discuss the design criteria of the robotic arm and how this design and the special arrangement of its muscular structure may bring the building of a robotic arm into being, by showing the results obtained by mathematical models and prototypical mock-ups.

  18. Design of a biomimetic robotic octopus arm

    International Nuclear Information System (INIS)

    Laschi, C; Cianchetti, M; Mazzolai, B; Dario, P; Mattoli, V

    2009-01-01

    This paper reports the rationale and design of a robotic arm, as inspired by an octopus arm. The octopus arm shows peculiar features, such as the ability to bend in all directions, to produce fast elongations, and to vary its stiffness. The octopus achieves these unique motor skills, thanks to its peculiar muscular structure, named muscular hydrostat. Different muscles arranged on orthogonal planes generate an antagonistic action on each other in the muscular hydrostat, which does not change its volume during muscle contractions, and allow bending and elongation of the arm and stiffness variation. By drawing inspiration from natural skills of octopus, and by analysing the geometry and mechanics of the muscular structure of its arm, we propose the design of a robot arm consisting of an artificial muscular hydrostat structure, which is completely soft and compliant, but also able to stiffen. In this paper, we discuss the design criteria of the robotic arm and how this design and the special arrangement of its muscular structure may bring the building of a robotic arm into being, by showing the results obtained by mathematical models and prototypical mock-ups

  19. The Development of light-weight 2-link robot arm for high radiation area

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ho Cheol; Seo, Yong Chil; Jung, Kyung Min; Choi, Young Soo

    2009-10-15

    A light-weight 2-link robot arm which weight is less than 8kg was developed for treating the small radio-active material in the high radiation area such as nuclear power plants and NDT area. The light-weight 2-link robot arm can be attached on a small mobile robot and carry out tasks. It is a 5 DOF robot arm including a gripper

  20. Robotic Mirror Therapy System for Functional Recovery of Hemiplegic Arms.

    Science.gov (United States)

    Beom, Jaewon; Koh, Sukgyu; Nam, Hyung Seok; Kim, Wonshik; Kim, Yoonjae; Seo, Han Gil; Oh, Byung-Mo; Chung, Sun Gun; Kim, Sungwan

    2016-08-15

    Mirror therapy has been performed as effective occupational therapy in a clinical setting for functional recovery of a hemiplegic arm after stroke. It is conducted by eliciting an illusion through use of a mirror as if the hemiplegic arm is moving in real-time while moving the healthy arm. It can facilitate brain neuroplasticity through activation of the sensorimotor cortex. However, conventional mirror therapy has a critical limitation in that the hemiplegic arm is not actually moving. Thus, we developed a real-time 2-axis mirror robot system as a simple add-on module for conventional mirror therapy using a closed feedback mechanism, which enables real-time movement of the hemiplegic arm. We used 3 Attitude and Heading Reference System sensors, 2 brushless DC motors for elbow and wrist joints, and exoskeletal frames. In a feasibility study on 6 healthy subjects, robotic mirror therapy was safe and feasible. We further selected tasks useful for activities of daily living training through feedback from rehabilitation doctors. A chronic stroke patient showed improvement in the Fugl-Meyer assessment scale and elbow flexor spasticity after a 2-week application of the mirror robot system. Robotic mirror therapy may enhance proprioceptive input to the sensory cortex, which is considered to be important in neuroplasticity and functional recovery of hemiplegic arms. The mirror robot system presented herein can be easily developed and utilized effectively to advance occupational therapy.

  1. Design and Implementation of Fire Extinguisher Robot with Robotic Arm

    Directory of Open Access Journals (Sweden)

    Memon Abdul Waris

    2018-01-01

    Full Text Available Robot is a device, which performs human task or behave like a human-being. It needs expertise skills and complex programming to design. For designing a fire fighter robot, many sensors and motors were used. User firstly send robot to an affected area, to get live image of the field with the help of mobile camera via Wi-Fi using IP camera application to laptop. If any signs of fire shown in image, user direct robot in that particular direction for confirmation. Fire sensor and temperature sensor detects and measures the reading, after confirmation robot sprinkle water on affected field. During extinguish process if any obstacle comes in between the prototype and the affected area the ultrasonic sensor detects the obstacle, in response the robotic arm moves to pick and place that obstacle to another location for clearing the path. Meanwhile if any poisonous gas is present, the gas sensor detects and indicates by making alarm.

  2. Robot-Arm Dynamic Control by Computer

    Science.gov (United States)

    Bejczy, Antal K.; Tarn, Tzyh J.; Chen, Yilong J.

    1987-01-01

    Feedforward and feedback schemes linearize responses to control inputs. Method for control of robot arm based on computed nonlinear feedback and state tranformations to linearize system and decouple robot end-effector motions along each of cartesian axes augmented with optimal scheme for correction of errors in workspace. Major new feature of control method is: optimal error-correction loop directly operates on task level and not on joint-servocontrol level.

  3. Neurosurgical robotic arm drilling navigation system.

    Science.gov (United States)

    Lin, Chung-Chih; Lin, Hsin-Cheng; Lee, Wen-Yo; Lee, Shih-Tseng; Wu, Chieh-Tsai

    2017-09-01

    The aim of this work was to develop a neurosurgical robotic arm drilling navigation system that provides assistance throughout the complete bone drilling process. The system comprised neurosurgical robotic arm navigation combining robotic and surgical navigation, 3D medical imaging based surgical planning that could identify lesion location and plan the surgical path on 3D images, and automatic bone drilling control that would stop drilling when the bone was to be drilled-through. Three kinds of experiment were designed. The average positioning error deduced from 3D images of the robotic arm was 0.502 ± 0.069 mm. The correlation between automatically and manually planned paths was 0.975. The average distance error between automatically planned paths and risky zones was 0.279 ± 0.401 mm. The drilling auto-stopping algorithm had 0.00% unstopped cases (26.32% in control group 1) and 70.53% non-drilled-through cases (8.42% and 4.21% in control groups 1 and 2). The system may be useful for neurosurgical robotic arm drilling navigation. Copyright © 2016 John Wiley & Sons, Ltd.

  4. Octopus-inspired multi-arm robotic swimming.

    Science.gov (United States)

    Sfakiotakis, M; Kazakidi, A; Tsakiris, D P

    2015-05-13

    The outstanding locomotor and manipulation characteristics of the octopus have recently inspired the development, by our group, of multi-functional robotic swimmers, featuring both manipulation and locomotion capabilities, which could be of significant engineering interest in underwater applications. During its little-studied arm-swimming behavior, as opposed to the better known jetting via the siphon, the animal appears to generate considerable propulsive thrust and rapid acceleration, predominantly employing movements of its arms. In this work, we capture the fundamental characteristics of the corresponding complex pattern of arm motion by a sculling profile, involving a fast power stroke and a slow recovery stroke. We investigate the propulsive capabilities of a multi-arm robotic system under various swimming gaits, namely patterns of arm coordination, which achieve the generation of forward, as well as backward, propulsion and turning. A lumped-element model of the robotic swimmer, which considers arm compliance and the interaction with the aquatic environment, was used to study the characteristics of these gaits, the effect of various kinematic parameters on propulsion, and the generation of complex trajectories. This investigation focuses on relatively high-stiffness arms. Experiments employing a compliant-body robotic prototype swimmer with eight compliant arms, all made of polyurethane, inside a water tank, successfully demonstrated this novel mode of underwater propulsion. Speeds of up to 0.26 body lengths per second (approximately 100 mm s(-1)), and propulsive forces of up to 3.5 N were achieved, with a non-dimensional cost of transport of 1.42 with all eight arms and of 0.9 with only two active arms. The experiments confirmed the computational results and verified the multi-arm maneuverability and simultaneous object grasping capability of such systems.

  5. Inverse kinematics of OWI-535 robotic arm

    OpenAIRE

    DEBENEC, PRIMOŽ

    2015-01-01

    The thesis aims to calculate the inverse kinematics for the OWI-535 robotic arm. The calculation of the inverse kinematics determines the joint parameters that provide the right pose of the end effector. The pose consists of the position and orientation, however, we will focus only on the second one. Due to arm limitations, we have created our own type of the calculation of the inverse kinematics. At first we have derived it only theoretically, and then we have transferred the derivation into...

  6. Special Gripper for a Robotic Arm

    Directory of Open Access Journals (Sweden)

    Miguel Angel SELLES

    2012-12-01

    Full Text Available New structures for gripping objects in robotic manipulation processes are oriented to the new arrangement of mechanical structures using new materials and processing technologies and innovative procedures for the implementation of contact gripping element links to an object with a high degree of adaptively of applications together with the ability to alter the structure of grip and limiting the intensity of the contact stiffness variation of snap elements custody and pliability. The application of elastomeric materials and surface finishes is important. This paper presents both a new gripper design for robot arms but also the search of the selected materials to make an experimental evaluation of technical parameters that are used to assess their application potential and suitability for the targeted applications. Also the results and conclusions for gripper testing in manipulation operations with two different robot arms are presented.

  7. Fuzzy Control of Robotic Arm

    Science.gov (United States)

    Lin, Kyaw Kyaw; Soe, Aung Kyaw; Thu, Theint Theint

    2008-10-01

    This research work investigates a Self-Tuning Proportional Derivative (PD) type Fuzzy Logic Controller (STPDFLC) for a two link robot system. The proposed scheme adjusts on-line the output Scaling Factor (SF) by fuzzy rules according to the current trend of the robot. The rule base for tuning the output scaling factor is defined on the error (e) and change in error (de). The scheme is also based on the fact that the controller always tries to manipulate the process input. The rules are in the familiar if-then format. All membership functions for controller inputs (e and de) and controller output (UN) are defined on the common interval [-1,1]; whereas the membership functions for the gain updating factor (α) is defined on [0,1]. There are various methods to calculate the crisp output of the system. Center of Gravity (COG) method is used in this application due to better results it gives. Performances of the proposed STPDFLC are compared with those of their corresponding PD-type conventional Fuzzy Logic Controller (PDFLC). The proposed scheme shows a remarkably improved performance over its conventional counterpart especially under parameters variation (payload). The two-link results of analysis are simulated. These simulation results are illustrated by using MATLAB® programming.

  8. Monitoring and Controlling an Underwater Robotic Arm

    Science.gov (United States)

    Haas, John; Todd, Brian Keith; Woodcock, Larry; Robinson, Fred M.

    2009-01-01

    The SSRMS Module 1 software is part of a system for monitoring an adaptive, closed-loop control of the motions of a robotic arm in NASA s Neutral Buoyancy Laboratory, where buoyancy in a pool of water is used to simulate the weightlessness of outer space. This software is so named because the robot arm is a replica of the Space Shuttle Remote Manipulator System (SSRMS). This software is distributed, running on remote joint processors (RJPs), each of which is mounted in a hydraulic actuator comprising the joint of the robotic arm and communicating with a poolside processor denoted the Direct Control Rack (DCR). Each RJP executes the feedback joint-motion control algorithm for its joint and communicates with the DCR. The DCR receives joint-angular-velocity commands either locally from an operator or remotely from computers that simulate the flight like SSRMS and perform coordinated motion calculations based on hand-controller inputs. The received commands are checked for validity before they are transmitted to the RJPs. The DCR software generates a display of the statuses of the RJPs for the DCR operator and can shut down the hydraulic pump when excessive joint-angle error or failure of a RJP is detected.

  9. Visual servo simulation of EAST articulated maintenance arm robot

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yang, E-mail: yangyang@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, 350 Shushanhu Rd, Hefei, Anhui (China); Song, Yuntao; Pan, Hongtao; Cheng, Yong; Feng, Hansheng [Institute of Plasma Physics, Chinese Academy of Sciences, 350 Shushanhu Rd, Hefei, Anhui (China); Wu, Huapeng [Lappeenranta University of Technology, Skinnarilankatu 34, Lappeenranta (Finland)

    2016-03-15

    For the inspection and light-duty maintenance of the vacuum vessel in the EAST tokamak, a serial robot arm, called EAST articulated maintenance arm, is developed. Due to the 9-m-long cantilever arm, the large flexibility of the EAMA robot introduces a problem in the accurate positioning. This article presents an autonomous robot control to cope with the robot positioning problem, which is a visual servo approach in context of tile grasping for the EAMA robot. In the experiments, the proposed method was implemented in a simulation environment to position and track a target graphite tile with the EAMA robot. As a result, the proposed visual control scheme can successfully drive the EAMA robot to approach and track the target tile until the robot reaches the desired position. Furthermore, the functionality of the simulation software presented in this paper is proved to be suitable for the development of the robotic and computer vision application.

  10. Visual servo simulation of EAST articulated maintenance arm robot

    International Nuclear Information System (INIS)

    Yang, Yang; Song, Yuntao; Pan, Hongtao; Cheng, Yong; Feng, Hansheng; Wu, Huapeng

    2016-01-01

    For the inspection and light-duty maintenance of the vacuum vessel in the EAST tokamak, a serial robot arm, called EAST articulated maintenance arm, is developed. Due to the 9-m-long cantilever arm, the large flexibility of the EAMA robot introduces a problem in the accurate positioning. This article presents an autonomous robot control to cope with the robot positioning problem, which is a visual servo approach in context of tile grasping for the EAMA robot. In the experiments, the proposed method was implemented in a simulation environment to position and track a target graphite tile with the EAMA robot. As a result, the proposed visual control scheme can successfully drive the EAMA robot to approach and track the target tile until the robot reaches the desired position. Furthermore, the functionality of the simulation software presented in this paper is proved to be suitable for the development of the robotic and computer vision application.

  11. Kinematics/statics analysis of a novel serial-parallel robotic arm with hand

    International Nuclear Information System (INIS)

    Lu, Yi; Dai, Zhuohong; Ye, Nijia; Wang, Peng

    2015-01-01

    A robotic arm with fingered hand generally has multi-functions to complete various complicated operations. A novel serial-parallel robotic arm with a hand is proposed and its kinematics and statics are studied systematically. A 3D prototype of the serial-parallel robotic arm with a hand is constructed and analyzed by simulation. The serial-parallel robotic arm with a hand is composed of an upper 3RPS parallel manipulator, a lower 3SPR parallel manipulator and a hand with three finger mechanisms. Its kinematics formulae for solving the displacement, velocity, acceleration of are derived. Its statics formula for solving the active/constrained forces is derived. Its reachable workspace and orientation workspace are constructed and analyzed. Finally, an analytic example is given for solving the kinematics and statics of the serial-parallel robotic arm with a hand and the analytic solutions are verified by a simulation mechanism.

  12. Kinematics/statics analysis of a novel serial-parallel robotic arm with hand

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Yi; Dai, Zhuohong; Ye, Nijia; Wang, Peng [Yanshan University, Hebei (China)

    2015-10-15

    A robotic arm with fingered hand generally has multi-functions to complete various complicated operations. A novel serial-parallel robotic arm with a hand is proposed and its kinematics and statics are studied systematically. A 3D prototype of the serial-parallel robotic arm with a hand is constructed and analyzed by simulation. The serial-parallel robotic arm with a hand is composed of an upper 3RPS parallel manipulator, a lower 3SPR parallel manipulator and a hand with three finger mechanisms. Its kinematics formulae for solving the displacement, velocity, acceleration of are derived. Its statics formula for solving the active/constrained forces is derived. Its reachable workspace and orientation workspace are constructed and analyzed. Finally, an analytic example is given for solving the kinematics and statics of the serial-parallel robotic arm with a hand and the analytic solutions are verified by a simulation mechanism.

  13. Investigating Astromaterials Curation Applications for Dexterous Robotic Arms

    Science.gov (United States)

    Snead, C. J.; Jang, J. H.; Cowden, T. R.; McCubbin, F. M.

    2018-01-01

    The Astromaterials Acquisition and Curation office at NASA Johnson Space Center is currently investigating tools and methods that will enable the curation of future astromaterials collections. Size and temperature constraints for astromaterials to be collected by current and future proposed missions will require the development of new robotic sample and tool handling capabilities. NASA Curation has investigated the application of robot arms in the past, and robotic 3-axis micromanipulators are currently in use for small particle curation in the Stardust and Cosmic Dust laboratories. While 3-axis micromanipulators have been extremely successful for activities involving the transfer of isolated particles in the 5-20 micron range (e.g. from microscope slide to epoxy bullet tip, beryllium SEM disk), their limited ranges of motion and lack of yaw, pitch, and roll degrees of freedom restrict their utility in other applications. For instance, curators removing particles from cosmic dust collectors by hand often employ scooping and rotating motions to successfully free trapped particles from the silicone oil coatings. Similar scooping and rotating motions are also employed when isolating a specific particle of interest from an aliquot of crushed meteorite. While cosmic dust curators have been remarkably successful with these kinds of particle manipulations using handheld tools, operator fatigue limits the number of particles that can be removed during a given extraction session. The challenges for curation of small particles will be exacerbated by mission requirements that samples be processed in N2 sample cabinets (i.e. gloveboxes). We have been investigating the use of compact robot arms to facilitate sample handling within gloveboxes. Six-axis robot arms potentially have applications beyond small particle manipulation. For instance, future sample return missions may involve biologically sensitive astromaterials that can be easily compromised by physical interaction with

  14. The Phoenix Mars Lander Robotic Arm

    Science.gov (United States)

    Bonitz, Robert; Shiraishi, Lori; Robinson, Matthew; Carsten, Joseph; Volpe, Richard; Trebi-Ollennu, Ashitey; Arvidson, Raymond E.; Chu, P. C.; Wilson, J. J.; Davis, K. R.

    2009-01-01

    The Phoenix Mars Lander Robotic Arm (RA) has operated for over 150 sols since the Lander touched down on the north polar region of Mars on May 25, 2008. During its mission it has dug numerous trenches in the Martian regolith, acquired samples of Martian dry and icy soil, and delivered them to the Thermal Evolved Gas Analyzer (TEGA) and the Microscopy, Electrochemistry, and Conductivity Analyzer (MECA). The RA inserted the Thermal and Electrical Conductivity Probe (TECP) into the Martian regolith and positioned it at various heights above the surface for relative humidity measurements. The RA was used to point the Robotic Arm Camera to take images of the surface, trenches, samples within the scoop, and other objects of scientific interest within its workspace. Data from the RA sensors during trenching, scraping, and trench cave-in experiments have been used to infer mechanical properties of the Martian soil. This paper describes the design and operations of the RA as a critical component of the Phoenix Mars Lander necessary to achieve the scientific goals of the mission.

  15. Kinect-Based Sliding Mode Control for Lynxmotion Robotic Arm

    Directory of Open Access Journals (Sweden)

    Ismail Ben Abdallah

    2016-01-01

    Full Text Available Recently, the technological development of manipulator robot increases very quickly and provides a positive impact to human life. The implementation of the manipulator robot technology offers more efficiency and high performance for several human’s tasks. In reality, efforts published in this context are focused on implementing control algorithms with already preprogrammed desired trajectories (passive robots case or trajectory generation based on feedback sensors (active robots case. However, gesture based control robot can be considered as another channel of system control which is not widely discussed. This paper focuses on a Kinect-based real-time interactive control system implementation. Based on LabVIEW integrated development environment (IDE, a developed human-machine-interface (HMI allows user to control in real time a Lynxmotion robotic arm. The Kinect software development kit (SDK provides a tool to keep track of human body skeleton and abstract it into 3-dimensional coordinates. Therefore, the Kinect sensor is integrated into our control system to detect the different user joints coordinates. The Lynxmotion dynamic has been implemented in a real-time sliding mode control algorithm. The experimental results are carried out to test the effectiveness of the system, and the results verify the tracking ability, stability, and robustness.

  16. Design and analysis on robotic arm for serving hazard container

    Science.gov (United States)

    Razali, Zol Bahri; Kader, Mohamed Mydin M. Abdul; Yi, Khoo Zern; Daud, Mohd Hisam

    2017-09-01

    This paper presents about design, analyses development and fabrication of robotic arm for sorting multi-material. The major problem that urges the initiation of the project is the fact that manufacturing industry is growing at relatively faster rate. Most of the company produce high load robotic arm. Less company creates light weight, and affordable robotic arm. As the result, light weight and affordable robot is developing to cover this issue. Plastic material was used to construct the body of the robotic arm, and an optical sensor was implemented to provide basic recognition of object to be carried. The robotic arm used five servomotors for overall operation; four for its joints, and one for the gripping mechanism. The gripper was designed and fabricated using Perspex due to the light weight and high strength of the material. The operation of the robotic arm was governed by Basic Stamp programming sequence and the device was expected to differentiate material and other objects based on reflective theory, and perform subsequent operations afterwards. The SolidWorks was used to model the detail design of the robotic arm, and to simulate the motion of the device.

  17. Phoenix Robotic Arm's Workspace After 90 Sols

    Science.gov (United States)

    2008-01-01

    During the first 90 Martian days, or sols, after its May 25, 2008, landing on an arctic plain of Mars, NASA's Phoenix Mars Lander dug several trenches in the workspace reachable with the lander's robotic arm. The lander's Surface Stereo Imager camera recorded this view of the workspace on Sol 90, early afternoon local Mars time (overnight Aug. 25 to Aug. 26, 2008). The shadow of the the camera itself, atop its mast, is just left of the center of the image and roughly a third of a meter (one foot) wide. The workspace is on the north side of the lander. The trench just to the right of center is called 'Neverland.' The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  18. Exact positioning of the robotic arm end effector

    Science.gov (United States)

    Korepanov, Valery; Dudkin, Fedir

    2016-07-01

    Orbital service becomes a new challenge of space exploration. The necessity to introduce it is connected first of all with an attractive opportunity to prolong the exploitation terms of expensive commercial satellites by, e.g., refilling of fuel or changing batteries. Other application area is a fight with permanently increasing amount of space litter - defunct satellites, burnt-out rocket stages, discarded trash and other debris. Now more than few tens of thousands orbiting objects larger than 5-10 cm (or about 1 million junks larger than 1 cm) are a huge problem for crucial and costly satellites and manned vehicles. For example, in 2014 the International Space Station had to change three times its orbit to avoid collision with space debris. So the development of the concepts and actions related to removal of space debris or non-operational satellites with use of robotic arm of a servicing satellite is very actual. Such a technology is also applicable for unmanned exploratory missions in solar system, for example for collecting a variety of samples from a celestial body surface. Naturally, the robotic arm movements should be controlled with great accuracy at influence of its non-rigidity, thermal and other factors. In these circumstances often the position of the arm end effector has to be controlled with high accuracy. The possibility of coordinate determination for the robotic arm end effector with use of a low frequency active electromagnetic system has been considered in the presented report. The proposed design of such a system consists of a small magnetic dipole source, which is mounted inside of the arm end effector and two or three 3-component magnetic field sensors mounted on a servicing satellite body. The data from this set of 3-component magnetic field sensors, which are fixed relatively to the satellite body, allows use of the mathematical approach for determination of position and orientation of the magnetic dipole source. The theoretical

  19. Tracked Robot with Blade Arms to Enhance Crawling Capability

    OpenAIRE

    Jhu-Wei Ji; Fa-Shian Chang; Lih-Tyng Hwang; Chih-Feng Liu; Jeng-Nan Lee; Shun-Min Wang; Kai-Yi Cho

    2016-01-01

    This paper presents a tracked robot with blade arms powered to assist movement in difficult environments. As a result, the tracked robot is able to pass a ramp or climb stairs. The main feature is a pair of blade arms on both sides of the vehicle body working in collaboration with previously validated transformable track system. When the robot encounters an obstacle in a terrain, it enlists the blade arms with power to overcome the obstacle. In disaster areas, there usually will be terrains t...

  20. Positioning the laparoscopic camera with industrial robot arm

    DEFF Research Database (Denmark)

    Capolei, Marie Claire; Wu, Haiyan; Andersen, Nils Axel

    2017-01-01

    This paper introduces a solution for the movement control of the laparoscopic camera employing a teleoperated robotic assistant. The project propose an autonomous robotic solution based on an industrial manipulator, provided with a modular software which is applicable to large scale. The robot arm...... industrial robot arm is designated to accomplish this manipulation task. The software is implemented in ROS in order to facilitate future extensions. The experimental results shows a manipulator capable of moving fast and smoothly the surgical tool around a remote center of motion....

  1. Robot-arm-based mobile HTS SQUID system for NDE of structures

    Energy Technology Data Exchange (ETDEWEB)

    Yotsugi, K; Hatsukade, Y; Tanaka, S [Department of Ecological Engineering, Toyohashi University of Technology, 1-1 Hibarigaoka, Tenpaku-cho, Toyohashi, Aichi 441-8580 (Japan)], E-mail: hatukade@eco.tut.ac.jp

    2008-02-01

    A robot-arm-based mobile HTS SQUID system was developed for NDE of fixed targets. To realize the system, active magnetic shielding technique using fluxgate as reference sensor for ambient field was applied to a cryocooler-based HTS SQUID gradiometer that was mounted on commercial robot-arm. In this technique, ambient field noise and pulse noise of 550 nT from robot were measured by the fluxgate near the SQUID, and then the fluxgate output was negatively fed back to generate compensation field around the SQUID and fluxgate. The noise from robot was reduced by a factor of about 20 and the shielding technique enabled the HTS SQUID to move in unshielded environment by the robot-arm without flux-trapping or unlocking at 10 mm/s. System noise measurement and inspection of hidden cracks in multi-layer composite-metal structure were demonstrated using the mobile SQUID-NDE system.

  2. Robust coordinated control of a dual-arm space robot

    Science.gov (United States)

    Shi, Lingling; Kayastha, Sharmila; Katupitiya, Jay

    2017-09-01

    Dual-arm space robots are more capable of implementing complex space tasks compared with single arm space robots. However, the dynamic coupling between the arms and the base will have a serious impact on the spacecraft attitude and the hand motion of each arm. Instead of considering one arm as the mission arm and the other as the balance arm, in this work two arms of the space robot perform as mission arms aimed at accomplishing secure capture of a floating target. The paper investigates coordinated control of the base's attitude and the arms' motion in the task space in the presence of system uncertainties. Two types of controllers, i.e. a Sliding Mode Controller (SMC) and a nonlinear Model Predictive Controller (MPC) are verified and compared with a conventional Computed-Torque Controller (CTC) through numerical simulations in terms of control accuracy and system robustness. Both controllers eliminate the need to linearly parameterize the dynamic equations. The MPC has been shown to achieve performance with higher accuracy than CTC and SMC in the absence of system uncertainties under the condition that they consume comparable energy. When the system uncertainties are included, SMC and CTC present advantageous robustness than MPC. Specifically, in a case where system inertia increases, SMC delivers higher accuracy than CTC and costs the least amount of energy.

  3. Experiments on co-operating robot arms

    International Nuclear Information System (INIS)

    Arthaya, B.; De Schutter, J.

    1994-01-01

    When two robots manipulate a common object or perform a single task together, a closed-kinematic chain is formed. If both robots are controlled under position control only, at a certain phase during the manipulation, the interaction forces may become unacceptably high. The interaction forces are caused by the kinematic as well as the dynamic errors in the robot position controller. In order to avoid this problem, a synchronized motion between both robots has to be generated, not only by controlling the position (velocity) of the two end-effectors, but also by controlling the interaction forces between them. In order to generate a synchronized motion, the first robot controller continuously modifies the task frame velocity corresponding to the velocity of the other robot. This implies that the velocity of the other robot is used as feed-forward information in order to anticipate its motion. This approach results in a better tracking behaviour

  4. A Simple Solution for Programming of a Robotic Arm

    Directory of Open Access Journals (Sweden)

    Bogdan Laurean

    2014-12-01

    Full Text Available This paper presents a method to actuate, programming and control of a Robotic arm based on a monomobil telescopic planetary gear and a DC motor. Experimental model of robot was designed and manufactured at the Faculty of Engineering from Sibiu, (Patent no. 112418 CI6.B25J 18/02. The DC motor as actuator rotates a reel. The wires on the reel will produce a linear displacement of telescopic modules. The command of the DC motor is realized by a programmable logic controller. The outputs of the programmable logic controller are connected in a "H" bridge. The rotation of the reel in one direction or another has the effect of lengthening or shortening the robotic arm. The value of robotic arm length is monitored by an optical incremental encoder. The value of displacement will correspond to number of steps from an up/down counter.

  5. Hand Gesture Based Wireless Robotic Arm Control for Agricultural Applications

    Science.gov (United States)

    Kannan Megalingam, Rajesh; Bandhyopadhyay, Shiva; Vamsy Vivek, Gedela; Juned Rahi, Muhammad

    2017-08-01

    One of the major challenges in agriculture is harvesting. It is very hard and sometimes even unsafe for workers to go to each plant and pluck fruits. Robotic systems are increasingly combined with new technologies to automate or semi automate labour intensive work, such as e.g. grape harvesting. In this work we propose a semi-automatic method for aid in harvesting fruits and hence increase productivity per man hour. A robotic arm fixed to a rover roams in the in orchard and the user can control it remotely using the hand glove fixed with various sensors. These sensors can position the robotic arm remotely to harvest the fruits. In this paper we discuss the design of hand glove fixed with various sensors, design of 4 DoF robotic arm and the wireless control interface. In addition the setup of the system and the testing and evaluation under lab conditions are also presented in this paper.

  6. Four Degree Freedom Robot Arm with Fuzzy Neural Network Control

    Directory of Open Access Journals (Sweden)

    Şinasi Arslan

    2013-01-01

    Full Text Available In this study, the control of four degree freedom robot arm has been realized with the computed torque control method.. It is usually required that the four jointed robot arm has high precision capability and good maneuverability for using in industrial applications. Besides, high speed working and external applied loads have been acting as important roles. For those purposes, the computed torque control method has been developed in a good manner that the robot arm can track the given trajectory, which has been able to enhance the feedback control together with fuzzy neural network control. The simulation results have proved that the computed torque control with the neural network has been so successful in robot control.

  7. Development of a 3D-Printed Robotic Prosthetic Arm

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Martinez, M.; Garcia-Miquel, A.; Vidal Martinez, N.

    2016-07-01

    Current prostheses are not affordable to the general public. 3D printing technology may allow low-cost production of such devices, making them more readily accessible to people in need. This contribution presents the set-up and the considerations that have to be taken into account to develop a functional artificial upper limb prototype. The robotic prosthetic arm reported herein was produced entirely using 3D printing technology to demonstrate its feasibility on a limited budget. The project was developed to integrate two different functional modes: a prosthetic application and a remote application. The prosthetic application is intended to emulate existing prosthetic devices using myoelectric sensors. The remote application is conceived as a tool for prevention, by providing the general public with a device that could carry out activities that entail a risk of severe physical injury. This is achieved using a hand-tracking system that allows the robotic arm to copy the user’s movements remotely and in real time. The outcome of the validation tests has been considerably successful for both applications and the total costs are on target. (Author)

  8. Visual Recognition and Its Application to Robot Arm Control

    Directory of Open Access Journals (Sweden)

    Jih-Gau Juang

    2015-10-01

    Full Text Available This paper presents an application of optical word recognition and fuzzy control to a smartphone automatic test system. The system consists of a robot arm and two webcams. After the words from the control panel that represent commands are recognized by the robot system, the robot arm performs the corresponding actions to test the smartphone. One of the webcams is utilized to capture commands on the screen of the control panel, the other to recognize the words on the screen of the tested smartphone. The method of image processing is based on the Red-Green-Blue (RGB and Hue-Saturation-Luminance (HSL color spaces to reduce the influence of light. Fuzzy theory is used in the robot arm’s position control. The Optical Character Recognition (OCR technique is applied to the word recognition, and the recognition results are then checked by a dictionary process to increase the recognition accuracy. The camera which is used to recognize the tested smartphone also provides object coordinates to the fuzzy controller, then the robot arm moves to the desired positions and presses the desired buttons. The proposed control scheme allows the robot arm to perform different assigned test functions successfully.

  9. Robotic vision system for random bin picking with dual-arm robots

    Directory of Open Access Journals (Sweden)

    Kang Sangseung

    2016-01-01

    Full Text Available Random bin picking is one of the most challenging industrial robotics applications available. It constitutes a complicated interaction between the vision system, robot, and control system. For a packaging operation requiring a pick-and-place task, the robot system utilized should be able to perform certain functions for recognizing the applicable target object from randomized objects in a bin. In this paper, we introduce a robotic vision system for bin picking using industrial dual-arm robots. The proposed system recognizes the best object from randomized target candidates based on stereo vision, and estimates the position and orientation of the object. It then sends the result to the robot control system. The system was developed for use in the packaging process of cell phone accessories using dual-arm robots.

  10. Optimization on robot arm machining by using genetic algorithms

    Science.gov (United States)

    Liu, Tung-Kuan; Chen, Chiu-Hung; Tsai, Shang-En

    2007-12-01

    In this study, an optimization problem on the robot arm machining is formulated and solved by using genetic algorithms (GAs). The proposed approach adopts direct kinematics model and utilizes GA's global search ability to find the optimum solution. The direct kinematics equations of the robot arm are formulated and can be used to compute the end-effector coordinates. Based on these, the objective of optimum machining along a set of points can be evolutionarily evaluated with the distance between machining points and end-effector positions. Besides, a 3D CAD application, CATIA, is used to build up the 3D models of the robot arm, work-pieces and their components. A simulated experiment in CATIA is used to verify the computation results first and a practical control on the robot arm through the RS232 port is also performed. From the results, this approach is proved to be robust and can be suitable for most machining needs when robot arms are adopted as the machining tools.

  11. An artificial flexible robot arm based on pneumatic muscle actuators

    Directory of Open Access Journals (Sweden)

    Renn Jyh-Chyang

    2017-01-01

    Full Text Available The purpose of this paper is to develop a novel human-friendly artificial flexible robot arm using four parallel-connected pneumatic muscle actuators (PMAs. The PMA is a flexible silicone rubber actuator which has some behaviors nearest to the real biological muscle including translational and rotational motions. An inverse kinematic model for the motion control is also developed. Finally, from experiment results, it is proved that not only the axial contraction control of a single PMA but also the attitude control of the whole pneumatic flexible robot arm using PID controller are satisfactory.

  12. Practical application with plc in manipulation of a robotic arm

    Directory of Open Access Journals (Sweden)

    Cristian Barz

    2014-12-01

    Full Text Available This paper presents the use of a robotic arm PLC Siemens in order not using CNC commands. This is done by programming the PLC ladder diagram language that makes movement on the three axes of the arm by means of stepper motors. Required command console PLC is built with the help of a touch screen HMI Weintek. In the user interface are introduced distances and displacement speeds on the three axes.

  13. Right-Arm Robotic-Aided-Therapy with the Light-Exoskeleton: A General Overview

    Science.gov (United States)

    Lugo-Villeda, Luis I.; Frisoli, Antonio; Sotgiu, Edoardo; Greco, Giovanni; Bergamasco, Massimo

    Rehabilitation robotics applications and their developments have been spreading out as consequences of the actual needs in the human activities of daily living (ADL). Exoskeletons for rehabilitation are one of them, whose intrinsic characteristics are quite useful for applications where repetitive, robustness and accurate performance are a must. As a part of robotic-mediated-rehabilitation programme into the worldwide, the exoskeletons are trying to improve the ADL of disable people through the fusion of several disciplines that lets to expand the capabilities of wearing a powered robotic exoskeletal device for rehabilitation tasks. This fact deserves to present this contribution from a general scope point of view, i.e., the technologies integration and its associated knowledge. So far, the Light-Exoskeleton which is intended for human arm rehabilitation in post-stroke patients is introduced. Preliminary experimental results as well as the involved stages about the system show the capabilities of using a robotic-constrained-rehabilitation for human arm.

  14. Goal driven kinematic simulation of flexible arm robot for space station missions

    Science.gov (United States)

    Janssen, P.; Choudry, A.

    1987-01-01

    Flexible arms offer a great degree of flexibility in maneuvering in the space environment. The problem of transporting an astronaut for extra-vehicular activity using a space station based flexible arm robot was studied. Inverse kinematic solutions of the multilink structure were developed. The technique is goal driven and can support decision making for configuration selection as required for stability and obstacle avoidance. Details of this technique and results are given.

  15. Coordination of dual robot arms using kinematic redundancy

    Science.gov (United States)

    Suh, Il Hong; Shin, Kang G.

    1988-01-01

    A method is developed to coordinate the motion of dual robot arms carrying a solid object, where the first robot (leader) grasps one end of the object rigidly and the second robot (follower) is allowed to change its grasping position at the other end of the object along the object surface while supporting the object. It is shown that this flexible grasping is equivalent to the addition of one more degree of freedom (dof), giving the follower more maneuvering capabilities. In particular, motion commands for the follower are generated by using kinematic redundancy. To show the utility and power of the method, an example system with two PUMA 560 robots carrying a beam is analyzed.

  16. Industrial dual arm robot manipulator for precise assembly of mechanical parts

    Science.gov (United States)

    Park, Chanhun; Kim, Doohyung; Park, Kyoungtaik; Choi, Youngjin

    2007-12-01

    A new structure of dual arm robot manipulator which consists of two industrial 6-DOF arms and one 2-DOF Torso is introduced. Each industrial 6-DOF arm is able to be used as a stand-alone industrial 6-DOF robot manipulator and as a part of dual arm manipulator at the same time. These structures help the robot maker which is willing to succeed in the emerging dual arm robot market in order to have high competition for the current industrial robot market at same time. Self-collision detection algorithm for multi-arm robot and kinematics algorithms for the developed dual arm robot manipulator which are implemented in our controller are introduced.

  17. Macrobend optical sensing for pose measurement in soft robot arms

    International Nuclear Information System (INIS)

    Sareh, Sina; Noh, Yohan; Liu, Hongbin; Althoefer, Kaspar; Li, Min; Ranzani, Tommaso

    2015-01-01

    This paper introduces a pose-sensing system for soft robot arms integrating a set of macrobend stretch sensors. The macrobend sensory design in this study consists of optical fibres and is based on the notion that bending an optical fibre modulates the intensity of the light transmitted through the fibre. This sensing method is capable of measuring bending, elongation and compression in soft continuum robots and is also applicable to wearable sensing technologies, e.g. pose sensing in the wrist joint of a human hand. In our arrangement, applied to a cylindrical soft robot arm, the optical fibres for macrobend sensing originate from the base, extend to the tip of the arm, and then loop back to the base. The connectors that link the fibres to the necessary opto-electronics are all placed at the base of the arm, resulting in a simplified overall design. The ability of this custom macrobend stretch sensor to flexibly adapt its configuration allows preserving the inherent softness and compliance of the robot which it is installed on. The macrobend sensing system is immune to electrical noise and magnetic fields, is safe (because no electricity is needed at the sensing site), and is suitable for modular implementation in multi-link soft continuum robotic arms. The measurable light outputs of the proposed stretch sensor vary due to bend-induced light attenuation (macrobend loss), which is a function of the fibre bend radius as well as the number of repeated turns. The experimental study conducted as part of this research revealed that the chosen bend radius has a far greater impact on the measured light intensity values than the number of turns (if greater than five). Taking into account that the bend radius is the only significantly influencing design parameter, the macrobend stretch sensors were developed to create a practical solution to the pose sensing in soft continuum robot arms. Henceforward, the proposed sensing design was benchmarked against an electromagnetic

  18. Automation and use of robotic arm for development and routine production of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Salvadori, P.A.; Di Sacco, S.; Riva, A.; Fusani, L.

    1993-01-01

    The target of a radiopharmaceutical group is twofold: production of radiotracers for clinical use (routine) and development of new compounds. The level of activity to be handled selects the strategy to be used for radiocompounds handling, ranging from direct manipulation during basic development at microcurie level to sophisticated equipments such as automated black-boxes and robotic arms at curie level. The authors looked for a common solution, to both the management of routine productions and the problems arising during activity scaling up in new tracer development, by choosing a robotic arm integrated by a variety of specialized automatic devices able to perform actions which are difficult (too slow, too precise, too complicated, etc.,) to be made by the robot. The final solution from this approach is a open-quotes synthetic stationclose quotes with flexible architecture which can be used for different applications without harware modification/adaptation

  19. INDUSTRIAL ROBOT ARM SIMULATION SOFTWARE DEVELOPMENT USING JAVA-3D AND MATLAB SIMULINK PROGRAMMING LANGUAGE

    OpenAIRE

    Wirabhuana, Arya

    2011-01-01

    Robot Arms Simulation Software development using Structured Programming Languages, Third Party Language, and Artificial Intelligence Programming Language are the common techniques in simulating robot arms movement. Those three techniques are having its strengths and weaknesses depend on several constraints such as robot type, degree of operation complexity to be simulated, operator skills, and also computer capability. This paper will discuss on Robot Arms Simulation Software (RSS) developmen...

  20. Ultra light inspection robotic arm, design and modeling

    International Nuclear Information System (INIS)

    Voisembert, S.

    2012-01-01

    One of the major challenges in robotics is the improvement of inspections operations in confined and hazardous area using unmanned remote handling systems. Articulated arm are used in this case to carry some diagnostic tools for the inspection tasks. These long reach multi-link carriers should be characterized by a large workspace and reduced mass. Today, with about ten degrees of freedom and ten meters long they have reached their performance limit. Indeed, for long reach, the arm should have enough torque to carry its own weight plus the payload in cantilever mode and enough stiffness to minimize the deflection caused by the gravity. Despite the use of best materials and components, this kind of robot has reach its performance limit. Overcoming this limit needs a change in paradigm. Therefore a problem-solving, analysis and forecasting tool TRIZ (theory of inventive problem solving) is used. It leads naturally to identify the origin of the dilemma: the proper weight of the arm and so its mass under gravity. In particular, it proposes to postulate that a no-mass robot exists. An analysis of the properties of such a robot leads to the patented concept of an ultra light inflatable robot with unique and constant volume and constant diameter joints. This new object would benefit from advantages such as easy implementation, harmlessness toward its environment and so the ability to lean on it without damage. Therefore it could easily increase its range and its foreseen low-cost building would open a wide field of new applications. This thesis work, elaborates appropriate technical concepts and dimensioning methods for ultra light inflatable robots. The payload and length performances of an inflatable robot are analytically validated. Experimentations and a finite-element modeling are used for a pre-dimensioning of the joints and different modes of construction are prototyped in partnership with, specialized company in thigh-tech textile. The joints are also modeled with

  1. Manual input device for controlling a robot arm

    International Nuclear Information System (INIS)

    Fischer, P.J.; Siva, K.V.

    1990-01-01

    A six-axis input device, eg joystick, is supported by a mechanism which enables the joystick to be aligned with any desired orientation, eg parallel to the tool. The mechanism can then be locked to provide a rigid support of the joystick. The mechanism may include three pivotal joints whose axes are perpendicular, each incorporating a clutch. The clutches may be electromagnetic or mechanical and may be operable jointly or independently. The robot arm comprises a base rotatable about a vertical axis, an upper arm, a forearm and a tool or grip rotatable about three perpendicular axes relative to the forearm. (author)

  2. In-Situ Operations and Planning for the Mars Science Laboratory Robotic Arm: The First 200 Sols

    Science.gov (United States)

    Robinson, M.; Collins, C.; Leger, P.; Carsten, J.; Tompkins, V.; Hartman, F.; Yen, J.

    2013-01-01

    The Robotic Arm (RA) has operated for more than 200 Martian solar days (or sols) since the Mars Science Laboratory rover touched down in Gale Crater on August 5, 2012. During the first seven months on Mars the robotic arm has performed multiple contact science sols including the positioning of the Alpha Particle X-Ray Spectrometer (APXS) and/or Mars Hand Lens Imager (MAHLI) with respect to rocks or loose regolith targets. The RA has supported sample acquisition using both the scoop and drill, sample processing with CHIMRA (Collection and Handling for In- Situ Martian Rock Analysis), and delivery of sample portions to the observation tray, and the SAM (Sample Analysis at Mars) and CHEMIN (Chemistry and Mineralogy) science instruments. This paper describes the planning and execution of robotic arm activities during surface operations, and reviews robotic arm performance results from Mars to date.

  3. High effective inverse dynamics modelling for dual-arm robot

    Science.gov (United States)

    Shen, Haoyu; Liu, Yanli; Wu, Hongtao

    2018-05-01

    To deal with the problem of inverse dynamics modelling for dual arm robot, a recursive inverse dynamics modelling method based on decoupled natural orthogonal complement is presented. In this model, the concepts and methods of Decoupled Natural Orthogonal Complement matrices are used to eliminate the constraint forces in the Newton-Euler kinematic equations, and the screws is used to express the kinematic and dynamics variables. On this basis, the paper has developed a special simulation program with symbol software of Mathematica and conducted a simulation research on the a dual-arm robot. Simulation results show that the proposed method based on decoupled natural orthogonal complement can save an enormous amount of CPU time that was spent in computing compared with the recursive Newton-Euler kinematic equations and the results is correct and reasonable, which can verify the reliability and efficiency of the method.

  4. Arm-eye coordination test to objectively quantify motor performance and muscles activation in persons after stroke undergoing robot-aided rehabilitation training: a pilot study.

    Science.gov (United States)

    Song, Rong; Tong, Kai-Yu; Hu, Xiaoling; Li, Le; Sun, Rui

    2013-09-01

    This study designed an arm-eye coordination test to investigate the effectiveness of the robot-aided rehabilitation for persons after stroke. Six chronic poststroke subjects were recruited to attend a 20-session robot-aided rehabilitation training of elbow joint. Before and after the training program, subjects were asked to perform voluntary movements of elbow flection and extension by following sinusoidal trajectories at different velocities with visual feedback on their joint positions. The elbow angle and the electromyographic signal of biceps and triceps as well as clinical scores were evaluated together with the parameters. Performance was objectively quantified by root mean square error (RMSE), root mean square jerk (RMSJ), range of motion (ROM), and co-contraction index (CI). After 20 sessions, RMSE and ROM improved significantly in both the affected and the unaffected side based on two-way ANOVA (P quantitative parameters and clinical scales could enable the exploration of effects of different types of treatment and design progress-based training method to accelerate the processes of recovery.

  5. Reference trajectory tracking for a multi-DOF robot arm

    Directory of Open Access Journals (Sweden)

    Krasňanský Róbert

    2015-12-01

    Full Text Available This paper presents the problem of tracking the generated reference trajectory by the simulation model of a multi-DOF robot arm. The kinematic transformation between task space and joint configuration coordinates is nonlinear and configuration dependent. To obtain the solution of the forward kinematics problem, the homogeneous transformation matrix is used. A solution to the inverse kinematics is a vector of joint configuration coordinates calculated using of pseudoinverse Jacobian technique. These coordinates correspond to a set of task space coordinates. The algorithm is presented which uses iterative solution and is simplified by considering stepper motors in robot arm joints. The reference trajectory in Cartesian coordinate system is generated on-line by the signal generator previously developed in MS Excel. Dynamic Data Exchange communication protocol allows sharing data with Matlab-Simulink. These data represent the reference tracking trajectory of the end effector. Matlab-Simulink software is used to calculate the representative joint rotations. The proposed algorithm is demonstrated experimentally on the model of 7-DOF robot arm system.

  6. Noninvasive Electroencephalogram Based Control of a Robotic Arm for Reach and Grasp Tasks

    Science.gov (United States)

    Meng, Jianjun; Zhang, Shuying; Bekyo, Angeliki; Olsoe, Jaron; Baxter, Bryan; He, Bin

    2016-01-01

    Brain-computer interface (BCI) technologies aim to provide a bridge between the human brain and external devices. Prior research using non-invasive BCI to control virtual objects, such as computer cursors and virtual helicopters, and real-world objects, such as wheelchairs and quadcopters, has demonstrated the promise of BCI technologies. However, controlling a robotic arm to complete reach-and-grasp tasks efficiently using non-invasive BCI has yet to be shown. In this study, we found that a group of 13 human subjects could willingly modulate brain activity to control a robotic arm with high accuracy for performing tasks requiring multiple degrees of freedom by combination of two sequential low dimensional controls. Subjects were able to effectively control reaching of the robotic arm through modulation of their brain rhythms within the span of only a few training sessions and maintained the ability to control the robotic arm over multiple months. Our results demonstrate the viability of human operation of prosthetic limbs using non-invasive BCI technology. PMID:27966546

  7. On the Value of Estimating Human Arm Stiffness during Virtual Teleoperation with Robotic Manipulators.

    Science.gov (United States)

    Buzzi, Jacopo; Ferrigno, Giancarlo; Jansma, Joost M; De Momi, Elena

    2017-01-01

    Teleoperated robotic systems are widely spreading in multiple different fields, from hazardous environments exploration to surgery. In teleoperation, users directly manipulate a master device to achieve task execution at the slave robot side; this interaction is fundamental to guarantee both system stability and task execution performance. In this work, we propose a non-disruptive method to study the arm endpoint stiffness. We evaluate how users exploit the kinetic redundancy of the arm to achieve stability and precision during the execution of different tasks with different master devices. Four users were asked to perform two planar trajectories following virtual tasks using both a serial and a parallel link master device. Users' arm kinematics and muscular activation were acquired and combined with a user-specific musculoskeletal model to estimate the joint stiffness. Using the arm kinematic Jacobian, the arm end-point stiffness was derived. The proposed non-disruptive method is capable of estimating the arm endpoint stiffness during the execution of virtual teleoperated tasks. The obtained results are in accordance with the existing literature in human motor control and show, throughout the tested trajectory, a modulation of the arm endpoint stiffness that is affected by task characteristics and hand speed and acceleration.

  8. On the Value of Estimating Human Arm Stiffness during Virtual Teleoperation with Robotic Manipulators

    Directory of Open Access Journals (Sweden)

    Jacopo Buzzi

    2017-09-01

    Full Text Available Teleoperated robotic systems are widely spreading in multiple different fields, from hazardous environments exploration to surgery. In teleoperation, users directly manipulate a master device to achieve task execution at the slave robot side; this interaction is fundamental to guarantee both system stability and task execution performance. In this work, we propose a non-disruptive method to study the arm endpoint stiffness. We evaluate how users exploit the kinetic redundancy of the arm to achieve stability and precision during the execution of different tasks with different master devices. Four users were asked to perform two planar trajectories following virtual tasks using both a serial and a parallel link master device. Users' arm kinematics and muscular activation were acquired and combined with a user-specific musculoskeletal model to estimate the joint stiffness. Using the arm kinematic Jacobian, the arm end-point stiffness was derived. The proposed non-disruptive method is capable of estimating the arm endpoint stiffness during the execution of virtual teleoperated tasks. The obtained results are in accordance with the existing literature in human motor control and show, throughout the tested trajectory, a modulation of the arm endpoint stiffness that is affected by task characteristics and hand speed and acceleration.

  9. End-Effector Position Analysis Using Forward Kinematics For 5 Dof Pravak Robot Arm

    Directory of Open Access Journals (Sweden)

    Jolly Atit Shah

    2013-03-01

    Full Text Available Automatic control of the robotic manipulator involves study of kinematics and dynamics as a major issue. This paper involves the kinematic analysis of a Pravak Robot arm which is used for doing successful robotic manipulation task in its workspace. The Pravak Robot Arm is a 5-DOF robot having all the joints revolute. The kinematics problem is defined as the transformation from the Cartesian space to the joint space and vice versa. In this study the Denavit- Hartenberg (D-H model is used to model robot links and joints. Pravak Robot Arm is a simple and safe robotic system designed for laboratory training and research applications. This robot allows to gain theoretical and practical experience in robotics, automation and control systems. The MATLAB R2007 is used to analyse end effectors position for a set of joint parameter.

  10. Kinematic equations for resolved-rate control of an industrial robot arm

    Science.gov (United States)

    Barker, L. K.

    1983-01-01

    An operator can use kinematic, resolved-rate equations to dynamically control a robot arm by watching its response to commanded inputs. Known resolved-rate equations for the control of a particular six-degree-of-freedom industrial robot arm and proceeds to simplify the equations for faster computations are derived. Methods for controlling the robot arm in regions which normally cause mathematical singularities in the resolved-rate equations are discussed.

  11. An Electromechanical Pendulum Robot Arm in Action: Dynamics and Control

    Directory of Open Access Journals (Sweden)

    A. Notué Kadjie

    2017-01-01

    Full Text Available The authors numerically investigate the dynamics and control of an electromechanical robot arm consisting of a pendulum coupled to an electrical circuit via an electromagnetic mechanism. The analysis of the dynamical behavior of the electromechanical device powered by a sinusoidal power source is carried out when the effects of the loads on the arm are neglected. It is found that the device exhibits period-n T oscillations and high amplitude oscillations when the electric current is at its smallest value. The specific case which considers the effects of the impulsive contact force caused by an external load mass pushed by the arm is also studied. It is found that the amplitude of the impulse force generates several behaviors such as jump of amplitude and distortions of the mechanical vibration and electrical signal. For more efficient functioning of the device, both piezoelectric and adaptive backstepping controls are applied on the system. It is found that the control strategies are able to mitigate the signal distortion and restore the dynamical behavior to its normal state or reduce the effects of perturbations such as a short time variation of one component or when the robot system is subject to noises.

  12. Robot-assisted arm assessments in spinal cord injured patients: a consideration of concept study.

    Directory of Open Access Journals (Sweden)

    Urs Keller

    Full Text Available Robotic assistance is increasingly used in neurological rehabilitation for enhanced training. Furthermore, therapy robots have the potential for accurate assessment of motor function in order to diagnose the patient status, to measure therapy progress or to feedback the movement performance to the patient and therapist in real time. We investigated whether a set of robot-based assessments that encompasses kinematic, kinetic and timing metrics is applicable, safe, reliable and comparable to clinical metrics for measurement of arm motor function. Twenty-four healthy subjects and five patients after spinal cord injury underwent robot-based assessments using the exoskeleton robot ARMin. Five different tasks were performed with aid of a visual display. Ten kinematic, kinetic and timing assessment parameters were extracted on joint- and end-effector level (active and passive range of motion, cubic reaching volume, movement time, distance-path ratio, precision, smoothness, reaction time, joint torques and joint stiffness. For cubic volume, joint torques and the range of motion for most joints, good inter- and intra-rater reliability were found whereas precision, movement time, distance-path ratio and smoothness showed weak to moderate reliability. A comparison with clinical scores revealed good correlations between robot-based joint torques and the Manual Muscle Test. Reaction time and distance-path ratio showed good correlation with the "Graded and Redefined Assessment of Strength, Sensibility and Prehension" (GRASSP and the Van Lieshout Test (VLT for movements towards a predefined position in the center of the frontal plane. In conclusion, the therapy robot ARMin provides a comprehensive set of assessments that are applicable and safe. The first results with spinal cord injured patients and healthy subjects suggest that the measurements are widely reliable and comparable to clinical scales for arm motor function. The methods applied and results can

  13. Co-Simulation Control of Robot Arm Dynamics in ADAMS and MATLAB

    OpenAIRE

    Luo Haitao; Liu Yuwang; Chen Zhengcang; Leng Yuquan

    2013-01-01

    The main objective of this study is how to quickly establish the virtual prototyping model of robot arm system and effectively solve trajectory tracking control for a given signal. Taking the 2-DOF robot arm as an example, a co-simulation control method is introduced to research multi-body dynamics. Using Newton-Euler and Lagrange method, respectively establish the dynamics model of robot arm and verify the correctness of equations. Firstly, the physical model of robot arm was built by PROE a...

  14. Designing, Fabrication and Controlling Of Multipurpose3-DOF Robotic Arm

    Science.gov (United States)

    Nabeel, Hafiz Muhammad; Azher, Anum; Usman Ali, Syed M.; Wahab Mughal, Abdul

    2013-12-01

    In the present work, we have successfully designed and developed a 3-DOF articulated Robotic Arm capable of performing typical industrial tasks such as painting or spraying, assembling and handling automobiles parts and etc., in resemblance to a human arm. The mechanical assembly is designed on SOLIDWORKS and aluminum grade 6061 -T6 is used for its fabrication in order to reduce the structure weight. We have applied inverse kinematics to determine the joint angles, equations are fed into an efficient microcontroller ATMEGA16 which performs all the calculations to determine the joint angles on the basis of given coordinates to actuate the joints through motorized control. Good accuracy was obtained with quadrature optical encoders installed in each joint to achieve the desired position and a LabVIEW based GUI is designed to provide human machine interface.

  15. Designing, Fabrication and Controlling Of Multipurpose3-DOF Robotic Arm

    International Nuclear Information System (INIS)

    Nabeel, Hafiz Muhammad; Azher, Anum; Ali, Syed M Usman; Mughal, Abdul Wahab

    2013-01-01

    In the present work, we have successfully designed and developed a 3-DOF articulated Robotic Arm capable of performing typical industrial tasks such as painting or spraying, assembling and handling automobiles parts and etc., in resemblance to a human arm. The mechanical assembly is designed on SOLIDWORKS and aluminum grade 6061 -T6 is used for its fabrication in order to reduce the structure weight. We have applied inverse kinematics to determine the joint angles, equations are fed into an efficient microcontroller ATMEGA16 which performs all the calculations to determine the joint angles on the basis of given coordinates to actuate the joints through motorized control. Good accuracy was obtained with quadrature optical encoders installed in each joint to achieve the desired position and a LabVIEW based GUI is designed to provide human machine interface

  16. Reach and grasp by people with tetraplegia using a neurally controlled robotic arm

    Science.gov (United States)

    Hochberg, Leigh R.; Bacher, Daniel; Jarosiewicz, Beata; Masse, Nicolas Y.; Simeral, John D.; Vogel, Joern; Haddadin, Sami; Liu, Jie; Cash, Sydney S.; van der Smagt, Patrick; Donoghue, John P.

    2012-01-01

    Paralysis following spinal cord injury (SCI), brainstem stroke, amyotrophic lateral sclerosis (ALS) and other disorders can disconnect the brain from the body, eliminating the ability to carry out volitional movements. A neural interface system (NIS)1–5 could restore mobility and independence for people with paralysis by translating neuronal activity directly into control signals for assistive devices. We have previously shown that people with longstanding tetraplegia can use an NIS to move and click a computer cursor and to control physical devices6–8. Able-bodied monkeys have used an NIS to control a robotic arm9, but it is unknown whether people with profound upper extremity paralysis or limb loss could use cortical neuronal ensemble signals to direct useful arm actions. Here, we demonstrate the ability of two people with long-standing tetraplegia to use NIS-based control of a robotic arm to perform three-dimensional reach and grasp movements. Participants controlled the arm over a broad space without explicit training, using signals decoded from a small, local population of motor cortex (MI) neurons recorded from a 96-channel microelectrode array. One of the study participants, implanted with the sensor five years earlier, also used a robotic arm to drink coffee from a bottle. While robotic reach and grasp actions were not as fast or accurate as those of an able-bodied person, our results demonstrate the feasibility for people with tetraplegia, years after CNS injury, to recreate useful multidimensional control of complex devices directly from a small sample of neural signals. PMID:22596161

  17. Robotics Activities in The Netherlands

    NARCIS (Netherlands)

    Kranenburg- de Lange, D.J.B.A.

    2010-01-01

    Since April 2010, in The Netherlands robotics activities are coordinated by RoboNED. This Dutch Robotics Platform, chaired by Prof. Stefano Stramigioli, aims to stimulate the synergy between the robotics fields and to formulate a focus. The goal of RoboNED is three fold: 1) RoboNED aims to bring the

  18. CONTROL SYSTEM FOR UNMANNED AIRCRAFT EQUIPPED WITH ROBOTICS ARM

    Directory of Open Access Journals (Sweden)

    Alexei A. Margun

    2014-11-01

    Full Text Available The paper deals with the problem of control system synthesis for multi rotational UAV equipped with robotics arm. Control algorithm is proposed based on the method of feedback linearization and synthesis of proportional-differential controller with the real time computation of the inertia tensor and center of mass changes and compensation of the reactive torque generated by the dynamics of the manipulator. Quadrocopter with attached articulated manipulator is selected as a model of the control object. Systems of equations describing the behavior of considered dynamical system are obtained according to the Newton and Euler-Lagrange laws. Expressions are offered, defining the inertia tensor and the position of the system center of mass depending on the current position of the manipulator, and the torque acting on the quadrocopter from the manipulator. Feedback linearization with arm influence compensation on quadrocopter is applied for the resulting nonlinear coupled system. As a result, robot dynamics equations have been converted to a linear stationary system. Converted system control is achieved by a proportional-differential controller. Examined system simulation is done with control method described in the paper and the classical method based on a proportional-differential controller. Simulation results confirm the effectiveness of the proposed approach and demonstrate that the proposed approach provides higher accuracy of the tracking error, than control method by means of proportional-differential regulator.

  19. Filtering sensory information with XCSF: improving learning robustness and robot arm control performance.

    Science.gov (United States)

    Kneissler, Jan; Stalph, Patrick O; Drugowitsch, Jan; Butz, Martin V

    2014-01-01

    It has been shown previously that the control of a robot arm can be efficiently learned using the XCSF learning classifier system, which is a nonlinear regression system based on evolutionary computation. So far, however, the predictive knowledge about how actual motor activity changes the state of the arm system has not been exploited. In this paper, we utilize the forward velocity kinematics knowledge of XCSF to alleviate the negative effect of noisy sensors for successful learning and control. We incorporate Kalman filtering for estimating successive arm positions, iteratively combining sensory readings with XCSF-based predictions of hand position changes over time. The filtered arm position is used to improve both trajectory planning and further learning of the forward velocity kinematics. We test the approach on a simulated kinematic robot arm model. The results show that the combination can improve learning and control performance significantly. However, it also shows that variance estimates of XCSF prediction may be underestimated, in which case self-delusional spiraling effects can hinder effective learning. Thus, we introduce a heuristic parameter, which can be motivated by theory, and which limits the influence of XCSF's predictions on its own further learning input. As a result, we obtain drastic improvements in noise tolerance, allowing the system to cope with more than 10 times higher noise levels.

  20. Arm reduced robotic-assisted laparoscopic hysterectomy with transvaginal cuff closure.

    Science.gov (United States)

    Bodur, Serkan; Dede, Murat; Fidan, Ulas; Firatligil, Burcin F; Ulubay, Mustafa; Ozturk, Mustafa; Yenen, Mufit C

    2017-09-01

    The use of robotics for benign etiology in gynecology has not proven to be more beneficial when compared to traditional laparoscopy. The major concern regarding robotic hysterectomy stems from its high cost. To evaluate the clinical utility and effectiveness of one-arm reduced robotic-assisted laparoscopic hysterectomy as a cost-effective surgical option for total robotic hysterectomy. A sample population of 54 women who underwent robotic-assisted laparoscopic surgery for benign gynecologic indications was evaluated, and two groups were identified: (1) the two-armed robotic-assisted laparoscopic surgery group (n = 38 patients), and (2) the three-armed robotic-assisted laparoscopic surgery group (n = 16 patients). An increased cost was observed when three-armed robotic surgery was employed for benign gynecologic surgery (p < 0.001). The cost reduction observed in the study group was primarily derived from one robotic arm reduction and vaginal closure of the cuff. This cost reduction was achieved without an increase in complication rates or undesirable postoperative outcomes. An estimated profit between $399.5 and $421.5 was made for each patient depending on the suture material chosen for cuff closure. Two-armed surgery resulted in an 18.6% reduction in procedure-specific costs for robotic hysterectomy. Two-armed robotic-assisted laparoscopic hysterectomy appears to be a cost-effective solution for robotic gynecologic surgery. This surgical solution can be performed as effectively as classical three-armed robotic hysterectomies for benign indications without the risk of increased surgical-related morbidities. This approach has the potential to be a widely preferred surgical approach in medical communities where cost reduction is one of the primary determinants of surgery type.

  1. Bioinspired locomotion and grasping in water: the soft eight-arm OCTOPUS robot.

    Science.gov (United States)

    Cianchetti, M; Calisti, M; Margheri, L; Kuba, M; Laschi, C

    2015-05-13

    The octopus is an interesting model for the development of soft robotics, due to its high deformability, dexterity and rich behavioural repertoire. To investigate the principles of octopus dexterity, we designed an eight-arm soft robot and evaluated its performance with focused experiments. The OCTOPUS robot presented here is a completely soft robot, which integrates eight arms extending in radial direction and a central body which contains the main processing units. The front arms are mainly used for elongation and grasping, while the others are mainly used for locomotion. The robotic octopus works in water and its buoyancy is close to neutral. The experimental results show that the octopus-inspired robot can walk in water using the same strategy as the animal model, with good performance over different surfaces, including walking through physical constraints. It can grasp objects of different sizes and shapes, thanks to its soft arm materials and conical shape.

  2. Reprogramming the articulated robotic arm for glass handling by using Arduino microcontroller

    Science.gov (United States)

    Razali, Zol Bahri; Kader, Mohamed Mydin M. Abdul; Kadir, Mohd Asmadi Akmal; Daud, Mohd Hisam

    2017-09-01

    The application of articulated robotic arm in industries is raised due to the expansion of using robot to replace human task, especially for the harmful tasks. However a few problems happen with the program use to schedule the arm, Thus the purpose of this project is to design, fabricate and integrate an articulated robotic arm by using Arduino microcontroller for handling glass sorting system. This project was designed to segregate glass and non-glass waste which would be pioneer step for recycling. This robotic arm has four servo motors to operate as a whole; three for the body and one for holding mechanism. This intelligent system is controlled by Arduino microcontroller and build with optical sensor to provide the distinguish objects that will be handled. Solidworks model was used to produce the detail design of the robotic arm and make the mechanical properties analysis by using a CAD software.

  3. Robotic Arm Control Algorithm Based on Stereo Vision Using RoboRealm Vision

    Directory of Open Access Journals (Sweden)

    SZABO, R.

    2015-05-01

    Full Text Available The goal of this paper is to present a stereo computer vision algorithm intended to control a robotic arm. Specific points on the robot joints are marked and recognized in the software. Using a dedicated set of mathematic equations, the movement of the robot is continuously computed and monitored with webcams. Positioning error is finally analyzed.

  4. End-Effector Position Analysis Using Forward Kinematics For 5 Dof Pravak Robot Arm

    OpenAIRE

    Jolly Atit Shah; S.S. Rattan; B.C. Nakra

    2013-01-01

    Automatic control of the robotic manipulator involves study of kinematics and dynamics as a major issue. This paper involves the kinematic analysis of a Pravak Robot arm which is used for doing successful robotic manipulation task in its workspace. The Pravak Robot Arm is a 5-DOF robot having all the joints revolute. The kinematics problem is defined as the transformation from the Cartesian space to the joint space and vice versa. In this study the Denavit- Hartenberg (D-H) model is used to m...

  5. Walking Pattern Generation of Dual-Arm Mobile Robot Using Preview Controller

    OpenAIRE

    P. Wu; W. Wu

    2012-01-01

    Based on the stability request of robot’s moving on the ground, the motion planning of dual-arm mobile robot when moving on the ground is studied and the preview control system is applied in the robot walking pattern generation. Direct question of robot kinematics in the extended task space is analyzed according to Degrees of Freedom configuration of the dual-arm mobile robot. It is proved that the preview control system could be used in the generation of robot Center of Mass forward trajecto...

  6. Fuzzy Logic and PID control of a 3 DOF Robotic Arm

    Directory of Open Access Journals (Sweden)

    Korhan Kayışlı

    2017-12-01

    Full Text Available The robotic arms are used in many industrial applications at the present time. At this point, high precision control is required for robotics used in fields such as healthcare area. Therefore, the control method applied to robots is also important. In this study, a force was applied to the end function of a three degree-of-freedom robot and the robustness of the controllers are tested. PID and Fuzzy Logic control method are used for this process. The control process of robotic arm which is designed and simulated is obtained by using Fuzzy Logic and classical PID controllers and the results are presented comparatively

  7. Fuzzy-Genetic Optimal Control for Four Degreeof Freedom Robotic Arm Movement

    OpenAIRE

    V. K. Banga; R. Kumar; Y. Singh

    2009-01-01

    In this paper, we present optimal control for movement and trajectory planning for four degrees-of-freedom robot using Fuzzy Logic (FL) and Genetic Algorithms (GAs). We have evaluated using Fuzzy Logic (FL) and Genetic Algorithms (GAs) for four degree-of-freedom (4 DOF) robotics arm, Uncertainties like; Movement, Friction and Settling Time in robotic arm movement have been compensated using Fuzzy logic and Genetic Algorithms. The development of a fuzzy genetic optimizatio...

  8. ITER Articulated Inspection Arm (AIA): Geometric calibration issues of a long-reach flexible robot

    International Nuclear Information System (INIS)

    Arhur, D.; Perrot, Y.; Bidard, C.; Friconneau, J.P.; Palmer, J.D.; Semeraro, L.

    2005-01-01

    This paper is part of the Remote Handling (RH) activities for the future fusion reactor ITER. Specifically it relates to the possibility to carry out close inspection tasks of the Vacuum Vessel first wall using a long reach robot called the 'Articulated Inspection Arm' (AIA). Early studies for this device identified the need of improving the accuracy of the end-effector position in such robot structures. Therefore, the aim of this R and D program performed under the European Fusion Development Agreement (EFDA) work program is to develop a flexible parametric model with localised compliances of an AIA-like system, in order to compensate for its flexibilities. The geometric calibration is performed using a non-linear multivariable optimisation technique, which minimizes the average error between the simulated and real robot position. The optimised set of parameters, tested on the first segment of the robot, enables to divide by 3 the error on the end-effector position, in comparison to a rigid model. We expect better prediction after mechanical improvements to reduce the serious backlash in the joints. The prediction model applied to the whole arm will enable errors to be reduced from more than 1 m, in some configurations, to a final accuracy of a few centimetres

  9. Brain-Machine Interface control of a robot arm using actor-critic rainforcement learning.

    Science.gov (United States)

    Pohlmeyer, Eric A; Mahmoudi, Babak; Geng, Shijia; Prins, Noeline; Sanchez, Justin C

    2012-01-01

    Here we demonstrate how a marmoset monkey can use a reinforcement learning (RL) Brain-Machine Interface (BMI) to effectively control the movements of a robot arm for a reaching task. In this work, an actor-critic RL algorithm used neural ensemble activity in the monkey's motor cortext to control the robot movements during a two-target decision task. This novel approach to decoding offers unique advantages for BMI control applications. Compared to supervised learning decoding methods, the actor-critic RL algorithm does not require an explicit set of training data to create a static control model, but rather it incrementally adapts the model parameters according to its current performance, in this case requiring only a very basic feedback signal. We show how this algorithm achieved high performance when mapping the monkey's neural states (94%) to robot actions, and only needed to experience a few trials before obtaining accurate real-time control of the robot arm. Since RL methods responsively adapt and adjust their parameters, they can provide a method to create BMIs that are robust against perturbations caused by changes in either the neural input space or the output actions they generate under different task requirements or goals.

  10. Kinematics analysis on hinges of robot arm gripper for harmful chemical handling

    Science.gov (United States)

    Razali, Zol Bahri; Kader, Mohamed Mydin M. Abdul; Mustafa, Nurul Fahimah; Daud, Mohd Hisam

    2017-09-01

    The development of manufacturing industry is booming the application of industrial robot, and proportional to the use of robot arm. Some of the purpose of robot arm gripper is to sort things and place to the proper place. And some of the things are harmful to human, such as harmful chemical. By using robot arm to do picking and placing, it is expected to replace human tasks, as well as to reduce human from the harmful job. The problem of the robot arm gripper, most likely the problem of hinge, thus the analysis on the hinges of robot arm gripper to prevent claw is essential. By using robot arm, instead of human, is labored to do the harmful tasks and unexpected accident happen, costs and expenses in handling injured employee due to the harmful chemicals can be minimized. Thus the objective of this project is to make a kinematics analysis on the hinges of the robot arm gripper. Suitable material such as steel structure has also been selected for the construction of this hinges. This material has properties associated with compressive strength, fire resistance, corrosion and has a shape that is easy to move. Solid Works and ANSYS software is used to create animated movement on the design model and to detect deficiencies in the hinges. Detail methodology is described in this paper.

  11. Animation of Panorama of Phoenix's Solar Panel and Robotic Arm

    Science.gov (United States)

    2008-01-01

    [figure removed for brevity, see original site] Click on image for animation This is an animation of panorama images of NASA's Phoenix Mars Lander's solar panel and the lander's Robotic Arm with a sample in the scoop. The image was taken just before the sample was delivered to the Optical Microscope. The images making up this animation were taken by the lander's Surface Stereo Imager looking west during Phoenix's Sol 16 (June 10, 2008), or the 16th Martian day after landing. This view is a part of the 'mission success' panorama that will show the whole landing site in color. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  12. Maximizing Use of Robot-Arm No. 3 in Da Vinci–Assisted Thoracic Surgery

    Science.gov (United States)

    Kajiwara, Naohiro; Maeda, Junichi; Yoshida, Koichi; Kato, Yasufumi; Hagiwara, Masaru; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2015-01-01

    We have previously reported on the importance of appropriate robot-arm settings and replacement of instrument ports in robot-assisted thoracic surgery, because the thoracic cavity requires a large space to access all lesions in various areas of the thoracic cavity from the apex to the diaphragm and mediastinum and the chest wall.1–3 Moreover, it can be difficult to manipulate the da Vinci Surgical System using only arms No. 1 and No. 2 depending on the tumor location. However, arm No. 3 is usually positioned on the same side as arm No. 2, and sometimes it is only used as an assisting-arm to avoid conflict with other arms (Fig. 1). In this report, we show how robot-arm No. 3 can be used with maximum effectiveness in da Vinci-assisted thoracic surgery. PMID:26011219

  13. Developing and modeling of voice control system for prosthetic robot arm in medical systems

    Directory of Open Access Journals (Sweden)

    Koksal Gundogdu

    2018-04-01

    Full Text Available In parallel with the development of technology, various control methods are also developed. Voice control system is one of these control methods. In this study, an effective modelling upon mathematical models used in the literature is performed, and a voice control system is developed in order to control prosthetic robot arms. The developed control system has been applied on four-jointed RRRR robot arm. Implementation tests were performed on the designed system. As a result of the tests; it has been observed that the technique utilized in our system achieves about 11% more efficient voice recognition than currently used techniques in the literature. With the improved mathematical modelling, it has been shown that voice commands could be effectively used for controlling the prosthetic robot arm. Keywords: Voice recognition model, Voice control, Prosthetic robot arm, Robotic control, Forward kinematic

  14. Some mechanical design aspects of the European Robotic Arm

    Science.gov (United States)

    Lambooy, Peter J.; Mandersloot, Wart M.; Bentall, Richard H.

    1995-01-01

    The European Robotic Arm (ERA) is a contribution to the Russian Segment of the International Space Station Alpha. It will start operating on the Russian Segment during the assembly phase. ERA is designed and produced by a large industrial consortium spread over Europe with Fokker Space & Systems as prime contractor. In this paper, we will describe some of the overall design aspects and focus on the development of several mechanisms within ERA. The operation of ERA during the approach of its end effector towards the grapple interface and the grapple operation is discussed, with a focus on mechanisms. This includes the geometry of the end effector leading edge, which is carefully designed to provide the correct and complete tactile information to a torque-force sensor (TFS). The data from this TFS are used to steer the arm such that forces and moments are kept below 20 N and 20 N.m respectively during the grappling operation. Two hardware models of the end effector are built. The problems encountered are described as well as their solutions. The joints in the wrists and the elbow initially used a harmonic drive lubricated by MoS2. During development testing, this combination showed an insufficient lifetime in air to survive the acceptance test program. The switch-over to a system comprising planetary gearboxes with grease lubrication is described. From these development efforts, conclusions are drawn and recommendations are given for the design of complex space mechanisms.

  15. Wheelchair-mounted robotic arm to hold and move a communication device - final design.

    Science.gov (United States)

    Barrett, Graham; Kurley, Kyle; Brauchie, Casey; Morton, Scott; Barrett, Steven

    2015-01-01

    At the 51st Rocky Mountain Bioengineering Symposium we presented a preliminary design for a robotic arm to assist an individual living within an assistive technology smart home. The individual controls much of their environment with a Dynavox Maestro communication device. However, the device obstructs the individual’s line of site when navigating about the smart home. A robotic arm was developed to move the communication device in and out of the user’s field of view as desired. The robotic arm is controlled by a conveniently mounted jelly switch. The jelly switch sends control signals to a four state (up, off, down, off) single-axis robotic arm interfaced to a DC motor by high power electronic relays. This paper describes the system, control circuitry, and multiple safety features. The arm will be delivered for use later in 2015.

  16. Novel Design of a Soft Lightweight Pneumatic Continuum Robot Arm with Decoupled Variable Stiffness and Positioning.

    Science.gov (United States)

    Giannaccini, Maria Elena; Xiang, Chaoqun; Atyabi, Adham; Theodoridis, Theo; Nefti-Meziani, Samia; Davis, Steve

    2018-02-01

    Soft robot arms possess unique capabilities when it comes to adaptability, flexibility, and dexterity. In addition, soft systems that are pneumatically actuated can claim high power-to-weight ratio. One of the main drawbacks of pneumatically actuated soft arms is that their stiffness cannot be varied independently from their end-effector position in space. The novel robot arm physical design presented in this article successfully decouples its end-effector positioning from its stiffness. An experimental characterization of this ability is coupled with a mathematical analysis. The arm combines the light weight, high payload to weight ratio and robustness of pneumatic actuation with the adaptability and versatility of variable stiffness. Light weight is a vital component of the inherent safety approach to physical human-robot interaction. To characterize the arm, a neural network analysis of the curvature of the arm for different input pressures is performed. The curvature-pressure relationship is also characterized experimentally.

  17. Position Control Method For Pick And Place Robot Arm For Object Sorting System

    Directory of Open Access Journals (Sweden)

    Khin Moe Myint

    2015-08-01

    Full Text Available The more increase the number of industries in developing countries the more require labourers or workers in that. To reduce the cost of labour force and to increase the manufacturing capacity of industries the advanced robot arms are more needed. The aim of this journal is to eliminate the manual control for object sorting system.Robot arm design in this research uses two joints three links and servo motors to drive. Microcontroller is used to generate required PWM signal for servo motors. In this research the position control of robot arm was designed by using kinematic control methods. There are two types of kinematic control methods which are forward and reverse kinematic methods. In forward kinematic method the input parameters are the joint angles and link length of robot arm and then the output is the position at XYZ coordinate of tool or gripper. In inverse kinematic the input parameters are position at XYZ coordinate of gripper and the link length of robot arm and then the output parameters are the joint angles. So kinematic methods can explain the analytical description of the geometry motion of the manipulator with reference to a robot coordinate system fixed to a frame without consideration of the forces or the moments causing the movements. For sorting system Metal detector is used to detect the metal or non-metal. This position control of pick and place robot arm is fully tested and the result is obtained more precisely.

  18. Passive reach and grasp with functional electrical stimulation and robotic arm support

    NARCIS (Netherlands)

    Westerveld, Ard J.; Schouten, Alfred C.; Veltink, Peter H.; van der Kooij, Herman

    2014-01-01

    Rehabilitation of arm and hand function is crucial to increase functional independence of stroke subjects. Here, we investigate the technical feasibility of an integrated training system combining robotics and functional electrical stimulation (FES) to support reach and grasp during functional

  19. Interface Based on Electrooculography for Velocity Control of a Robot Arm

    Directory of Open Access Journals (Sweden)

    Eduardo Iáñez

    2010-01-01

    Full Text Available This paper describes a technique based on electrooculography to control a robot arm. This technique detects the movement of the eyes, measuring the difference of potential between the cornea and the retina by placing electrodes around the ocular area. The processing algorithm developed to obtain the position of the eye at the blink of the user is explained. The output of the processing algorithm offers, apart from the direction, four different values (zero to three to control the velocity of the robot arm according to how much the user is looking in one direction. This allows controlling two degrees of freedom of a robot arm with the eyes movement. The blink has been used to mark some targets in tests. In this paper, the experimental results obtained with a real robot arm are shown.

  20. MOVEMENT SIMULATION OF THREE ARMED ROBOT BY BEING USED AutoLISP

    Directory of Open Access Journals (Sweden)

    Mustafa BOZDEMİR

    2000-01-01

    Full Text Available Development of a suitable robot for desired aim and duty is very important for design enginers. On the other hand, designed robots may be unsuccesful in functioning inspite of many efforts. For this reason, before the production of considered robot systems, having prepared a simulation program, investigation of work field, getting done path plan and mistakes could be eliminated before robot production. In this study, movement simulation of a three armed robot has been realized by using AutoLIPS programing language which is supplied with AutoCAD. Analytical and matrix solution methods have been used in simulation equations.

  1. Using a Robotic Arm to Evaluate the Programming Ability of K-12 Educators

    Directory of Open Access Journals (Sweden)

    Antoinette Bruciati

    2006-12-01

    Full Text Available This usability study measured the ability of educators to master advanced computer programming concepts through the OWI Robotic Arm Trainer and PC Interface. Research findings revealed that the lack of prior computer programming experience did not impact the ability of each participant to successfully program his/her robotic arm. However, the absence of a detailed instructional manual detracted from the product

  2. Desain Proportional Integral Derrivative (Pid) Controller Pada Model Arm Robot Manipulator

    OpenAIRE

    Pratama, Adhityanendra Pandu; Munadi, Munadi

    2014-01-01

    Dalam rangka menuju proses industrialisasi modern di negara Indonesia, harus didukung dengan teknologi yang canggih, contoh nya adalah arm robot manipulator. sebagai pelaku proses produksi sehingga dihasilkan ketepatan,kepresisian, dan kefektifan pada proses produksi. Dengan hal tersebut dibuat sebuah desain kontrol PID pada arm robot manipulator dengan tujuan menghasilkan tingkat presisi dan kestabilan yang lebih baik. Kontroler tersebut didesain, disimulasikan, dan diaplikasikan pada ha...

  3. Analysis of reaching movements of upper arm in robot assisted exercises. Kinematic assessment of robot assisted upper arm reaching single-joint movements.

    Science.gov (United States)

    Iuppariello, Luigi; D'Addio, Giovanni; Romano, Maria; Bifulco, Paolo; Lanzillo, Bernardo; Pappone, Nicola; Cesarelli, Mario

    2016-01-01

    Robot-mediated therapy (RMT) has been a very dynamic area of research in recent years. Robotics devices are in fact capable to quantify the performances of a rehabilitation task in treatments of several disorders of the arm and the shoulder of various central and peripheral etiology. Different systems for robot-aided neuro-rehabilitation are available for upper limb rehabilitation but the biomechanical parameters proposed until today, to evaluate the quality of the movement, are related to the specific robot used and to the type of exercise performed. Besides, none study indicated a standardized quantitative evaluation of robot assisted upper arm reaching movements, so the RMT is still far to be considered a standardised tool. In this paper a quantitative kinematic assessment of robot assisted upper arm reaching movements, considering also the effect of gravity on the quality of the movements, is proposed. We studied a group of 10 healthy subjects and results indicate that our advised protocol can be useful for characterising normal pattern in reaching movements.

  4. Controlling Flexible Robot Arms Using High Speed Dynamics Process

    Science.gov (United States)

    Jain, Abhinandan (Inventor)

    1996-01-01

    A robot manipulator controller for a flexible manipulator arm having plural bodies connected at respective movable hinges and flexible in plural deformation modes corresponding to respective modal spatial influence vectors relating deformations of plural spaced nodes of respective bodies to the plural deformation modes, operates by computing articulated body quantities for each of the bodies from respective modal spatial influence vectors, obtaining specified body forces for each of the bodies, and computing modal deformation accelerations of the nodes and hinge accelerations of the hinges from the specified body forces, from the articulated body quantities and from the modal spatial influence vectors. In one embodiment of the invention, the controller further operates by comparing the accelerations thus computed to desired manipulator motion to determine a motion discrepancy, and correcting the specified body forces so as to reduce the motion discrepancy. The manipulator bodies and hinges are characterized by respective vectors of deformation and hinge configuration variables, and computing modal deformation accelerations and hinge accelerations is carried out for each one of the bodies beginning with the outermost body by computing a residual body force from a residual body force of a previous body and from the vector of deformation and hinge configuration variables, computing a resultant hinge acceleration from the body force, the residual body force and the articulated hinge inertia, and revising the residual body force modal body acceleration.

  5. Controlling flexible robot arms using a high speed dynamics process

    Science.gov (United States)

    Jain, Abhinandan (Inventor); Rodriguez, Guillermo (Inventor)

    1992-01-01

    Described here is a robot controller for a flexible manipulator arm having plural bodies connected at respective movable hinges, and flexible in plural deformation modes. It is operated by computing articulated body qualities for each of the bodies from the respective modal spatial influence vectors, obtaining specified body forces for each of the bodies, and computing modal deformation accelerations of the nodes and hinge accelerations of the hinges from the specified body forces, from the articulated body quantities and from the modal spatial influence vectors. In one embodiment of the invention, the controller further operates by comparing the accelerations thus computed to desired manipulator motion to determine a motion discrepancy, and correcting the specified body forces so as to reduce the motion discrepancy. The manipulator bodies and hinges are characterized by respective vectors of deformation and hinge configuration variables. Computing modal deformation accelerations and hinge accelerations is carried out for each of the bodies, beginning with the outermost body by computing a residual body force from a residual body force of a previous body, computing a resultant hinge acceleration from the body force, and then, for each one of the bodies beginning with the innermost body, computing a modal body acceleration from a modal body acceleration of a previous body, computing a modal deformation acceleration and hinge acceleration from the resulting hinge acceleration and from the modal body acceleration.

  6. Translational control of a graphically simulated robot arm by kinematic rate equations that overcome elbow joint singularity

    Science.gov (United States)

    Barker, L. K.; Houck, J. A.; Carzoo, S. W.

    1984-01-01

    An operator commands a robot hand to move in a certain direction relative to its own axis system by specifying a velocity in that direction. This velocity command is then resolved into individual joint rotational velocities in the robot arm to effect the motion. However, the usual resolved-rate equations become singular when the robot arm is straightened. To overcome this elbow joint singularity, equations were developed which allow continued translational control of the robot hand even though the robot arm is (or is nearly) fully extended. A feature of the equations near full arm extension is that an operator simply extends and retracts the robot arm to reverse the direction of the elbow bend (difficult maneuver for the usual resolved-rate equations). Results show successful movement of a graphically simulated robot arm.

  7. Software Development for the Kinematic Analysis of a Lynx 6 Robot Arm

    OpenAIRE

    Baki Koyuncu; Mehmet Güzel

    2007-01-01

    The kinematics of manipulators is a central problem in the automatic control of robot manipulators. Theoretical background for the analysis of the 5 Dof Lynx-6 educational Robot Arm kinematics is presented in this paper. The kinematics problem is defined as the transformation from the Cartesian space to the joint space and vice versa. The Denavit-Harbenterg (D-H) model of representation is used to model robot links and joints in this study. Both forward and inverse kinematics solutions for th...

  8. Robot-assisted reaching exercise promotes arm movement recovery in chronic hemiparetic stroke: a randomized controlled pilot study

    Directory of Open Access Journals (Sweden)

    Rymer W Zev

    2006-06-01

    Full Text Available Abstract Background and purpose Providing active assistance to complete desired arm movements is a common technique in upper extremity rehabilitation after stroke. Such active assistance may improve recovery by affecting somatosensory input, motor planning, spasticity or soft tissue properties, but it is labor intensive and has not been validated in controlled trials. The purpose of this study was to investigate the effects of robotically administered active-assistive exercise and compare those with free reaching voluntary exercise in improving arm movement ability after chronic stroke. Methods Nineteen individuals at least one year post-stroke were randomized into one of two groups. One group performed 24 sessions of active-assistive reaching exercise with a simple robotic device, while a second group performed a task-matched amount of unassisted reaching. The main outcome measures were range and speed of supported arm movement, range, straightness and smoothness of unsupported reaching, and the Rancho Los Amigos Functional Test of Upper Extremity Function. Results and discussion There were significant improvements with training for range of motion and velocity of supported reaching, straightness of unsupported reaching, and functional movement ability. These improvements were not significantly different between the two training groups. The group that performed unassisted reaching exercise improved the smoothness of their reaching movements more than the robot-assisted group. Conclusion Improvements with both forms of exercise confirmed that repeated, task-related voluntary activation of the damaged motor system is a key stimulus to motor recovery following chronic stroke. Robotically assisting in reaching successfully improved arm movement ability, although it did not provide any detectable, additional value beyond the movement practice that occurred concurrently with it. The inability to detect any additional value of robot-assisted reaching

  9. Development of a multisensory arm for process monitoring in Robot Assisted Polishing

    DEFF Research Database (Denmark)

    Pilny, Lukas; Dalla Costa, Giuseppe; Bissacco, Giuliano

    2015-01-01

    A multisensory polishing arm with integrated three component force sensor, a miniature acoustic emission (AE) sensor and an accelerometer was developed for process monitoring in Robot Assisted Polishing (RAP) process. The arm design was optimized for integration of a force and an AE sensor. The f...

  10. Closed-Loop Hybrid Gaze Brain-Machine Interface Based Robotic Arm Control with Augmented Reality Feedback

    Directory of Open Access Journals (Sweden)

    Hong Zeng

    2017-10-01

    Full Text Available Brain-machine interface (BMI can be used to control the robotic arm to assist paralysis people for performing activities of daily living. However, it is still a complex task for the BMI users to control the process of objects grasping and lifting with the robotic arm. It is hard to achieve high efficiency and accuracy even after extensive trainings. One important reason is lacking of sufficient feedback information for the user to perform the closed-loop control. In this study, we proposed a method of augmented reality (AR guiding assistance to provide the enhanced visual feedback to the user for a closed-loop control with a hybrid Gaze-BMI, which combines the electroencephalography (EEG signals based BMI and the eye tracking for an intuitive and effective control of the robotic arm. Experiments for the objects manipulation tasks while avoiding the obstacle in the workspace are designed to evaluate the performance of our method for controlling the robotic arm. According to the experimental results obtained from eight subjects, the advantages of the proposed closed-loop system (with AR feedback over the open-loop system (with visual inspection only have been verified. The number of trigger commands used for controlling the robotic arm to grasp and lift the objects with AR feedback has reduced significantly and the height gaps of the gripper in the lifting process have decreased more than 50% compared to those trials with normal visual inspection only. The results reveal that the hybrid Gaze-BMI user can benefit from the information provided by the AR interface, improving the efficiency and reducing the cognitive load during the grasping and lifting processes.

  11. Closed-Loop Hybrid Gaze Brain-Machine Interface Based Robotic Arm Control with Augmented Reality Feedback

    Science.gov (United States)

    Zeng, Hong; Wang, Yanxin; Wu, Changcheng; Song, Aiguo; Liu, Jia; Ji, Peng; Xu, Baoguo; Zhu, Lifeng; Li, Huijun; Wen, Pengcheng

    2017-01-01

    Brain-machine interface (BMI) can be used to control the robotic arm to assist paralysis people for performing activities of daily living. However, it is still a complex task for the BMI users to control the process of objects grasping and lifting with the robotic arm. It is hard to achieve high efficiency and accuracy even after extensive trainings. One important reason is lacking of sufficient feedback information for the user to perform the closed-loop control. In this study, we proposed a method of augmented reality (AR) guiding assistance to provide the enhanced visual feedback to the user for a closed-loop control with a hybrid Gaze-BMI, which combines the electroencephalography (EEG) signals based BMI and the eye tracking for an intuitive and effective control of the robotic arm. Experiments for the objects manipulation tasks while avoiding the obstacle in the workspace are designed to evaluate the performance of our method for controlling the robotic arm. According to the experimental results obtained from eight subjects, the advantages of the proposed closed-loop system (with AR feedback) over the open-loop system (with visual inspection only) have been verified. The number of trigger commands used for controlling the robotic arm to grasp and lift the objects with AR feedback has reduced significantly and the height gaps of the gripper in the lifting process have decreased more than 50% compared to those trials with normal visual inspection only. The results reveal that the hybrid Gaze-BMI user can benefit from the information provided by the AR interface, improving the efficiency and reducing the cognitive load during the grasping and lifting processes. PMID:29163123

  12. Optimal Control of Holding Motion by Nonprehensile Two-Cooperative-Arm Robot

    Directory of Open Access Journals (Sweden)

    Changan Jiang

    2016-01-01

    Full Text Available Recently, more researchers have focused on nursing-care assistant robot and placed their hope on it to solve the shortage problem of the caregivers in hospital or nursing home. In this paper, a nonprehensile two-cooperative-arm robot is considered to realize holding motion to keep a two-rigid-link object (regarded as a care-receiver stable on the robot arms. By applying Newton-Euler equations of motion, dynamic model of the object is obtained. In this model, for describing interaction behavior between object and robot arms in the normal direction, a viscoelastic model is employed to represent the normal forces. Considering existence of friction between object and robot arms, LuGre dynamic model is applied to describe the friction. Based on the obtained model, an optimal regulator is designed to control the holding motion of two-cooperative-arm robot. In order to verify the effectiveness of the proposed method, simulation results are shown.

  13. The Development of Control System Design for 5 DOF Nuclear Malaysia Robot Arm v2

    International Nuclear Information System (INIS)

    Mohd Zaid Hassan; Anwar Abdul Rahman; Rosli Darmawan; Mohd Arif Hamzah

    2011-01-01

    This paper describes a general design and implementation approach used for programming and controlling robotic systems such as remotely operated robotic manipulator systems. A hierarchical approach to control system design is adopted. The hierarchical design is translated into a component-based software design. A low-cost robotic arm and controller system is presented. The controller is a modular model of the robotic arm with the same degrees of freedom whose joints are equipped with sensors. The system takes advantage of the low cost and wide availability of control components and uses a low-cost, easy-to-program microprocessor. Furthermore, it presents the design and the construction of electronic systems for the control of an articulated robot developed for research and development related with instrumentation and control. The system is simple but it is designed the motor to move the robot arm to proper angular position according to the input controller. Limitations of the micro controller are discussed, and suggestions for further development of the robot arm and control are made. (author)

  14. Kinematics study and workspace analysis of an articulated robotic arm of a rpar

    International Nuclear Information System (INIS)

    Zeb, J.; Rashid, F.; Iqbal, N.

    2007-01-01

    An itinerant RPAR (Radiation Protection Assistant Robot) has been constructed to assist radiation workers in radiation area which are radiologically hazardous and beyond tile safe approach of radiation workers. The RPAR comprises of a cubicle tri- wheeled platform and a 4-DOF (Four Degree of Freedom) serial type articulated robotic arm. The movement of the platform is controlled by two differential wheeled driving systems. The Kinematics and Manipulator Jacobian of the end-effector (gripper) of the articulated robotic arm mounted on the RPAR were evaluated. The work space analyses of the articulated robotic arm have been carried out. The RPAR is helpful for surveillance of radiation zones, to pick and carry dropdown radioactive samples and sources, in routine radiological operations as well as during an emergency response to a radiological accident. The performance of the RPAR was found satisfactory. (author)

  15. Concept development of a tendon arm manipulator and anthropomorphic robotic hand

    Science.gov (United States)

    Tolman, C. T.

    1987-01-01

    AMETEK/ORED inhouse research and development efforts leading toward a next-generation robotic manipulator arm and end-effector technology is summarized. Manipulator arm development has been directed toward a multiple-degree-of-freedom, flexible, tendon-driven concept referred to here as a Tendon Arm Manipulator (TAM). End-effector development has been directed toward a three-fingered, dextrous, tendon-driven, anthropomorphic configuration which is referred to as an Anthropomorphic Robotic Hand (ARH). Key technology issues are identified for both concepts.

  16. JACoW A dual arms robotic platform control for navigation, inspection and telemanipulation

    CERN Document Server

    Di Castro, Mario; Ferre, Manuel; Gilardoni, Simone; Losito, Roberto; Lunghi, Giacomo; Masi, Alessandro

    2018-01-01

    High intensity hadron colliders and fixed target experiments require an increasing amount of robotic tele-manipulation to prevent excessive exposure of maintenance personnel to the radioactive environment. Telemanipulation tasks are often required on old radioactive devices not conceived to be maintained and handled using standard industrial robotic solutions. Robotic platforms with a level of dexterity that often require the use of two robotic arms with a minimum of six degrees of freedom are instead needed for these purposes. In this paper, the control of a novel robust robotic platform able to host and to carry safely a dual robotic arm system is presented. The control of the arms is fully integrated with the vehicle control in order to guarantee simplicity to the operators during the realization of the robotic tasks. A novel high-level control architecture for the new robot is shown, as well as a novel low level safety layer for anti-collision and recovery scenarios. Preliminary results of the system comm...

  17. Coordinated trajectory planning of dual-arm space robot using constrained particle swarm optimization

    Science.gov (United States)

    Wang, Mingming; Luo, Jianjun; Yuan, Jianping; Walter, Ulrich

    2018-05-01

    Application of the multi-arm space robot will be more effective than single arm especially when the target is tumbling. This paper investigates the application of particle swarm optimization (PSO) strategy to coordinated trajectory planning of the dual-arm space robot in free-floating mode. In order to overcome the dynamics singularities issue, the direct kinematics equations in conjunction with constrained PSO are employed for coordinated trajectory planning of dual-arm space robot. The joint trajectories are parametrized with Bézier curve to simplify the calculation. Constrained PSO scheme with adaptive inertia weight is implemented to find the optimal solution of joint trajectories while specific objectives and imposed constraints are satisfied. The proposed method is not sensitive to the singularity issue due to the application of forward kinematic equations. Simulation results are presented for coordinated trajectory planning of two kinematically redundant manipulators mounted on a free-floating spacecraft and demonstrate the effectiveness of the proposed method.

  18. Brain-state dependent robotic reaching movement with a multi-joint arm exoskeleton: combining brain-machine interfacing and robotic rehabilitation

    Directory of Open Access Journals (Sweden)

    Daniel eBrauchle

    2015-10-01

    Full Text Available While robot-assisted arm and hand training after stroke allows for intensive task-oriented practice, it has provided only limited additional benefit over dose-matched physiotherapy up to now. These rehabilitation devices are possibly too supportive during the exercises. Neurophysiological signals might be one way of avoiding slacking and providing robotic support only when the brain is particularly responsive to peripheral input.We tested the feasibility of three-dimensional robotic assistance for reach-to-grasp movements with a multi-joint exoskeleton during motor imagery-related desynchronization of sensorimotor oscillations in the β-band only. We also registered task-related network changes of cortical functional connectivity by electroencephalography via the imaginary part of the coherence function.Healthy subjects and stroke survivors showed similar patterns – but different aptitudes – of controlling the robotic movement. All participants in this pilot study with nine healthy subjects and two stroke patients achieved their maximum performance during the early stages of the task. Robotic control was significantly higher and less variable when proprioceptive feedback was provided in addition to visual feedback, i.e. when the orthosis was actually attached to the subject’s arm during the task. A distributed cortical network of task-related coherent activity in the θ-band showed significant differences between healthy subjects and stroke patients as well as between early and late periods of the task.Brain-robot interfaces may successfully link three-dimensional robotic training to the participants’ efforts and allow for task-oriented practice of activities of daily living with a physiologically controlled multi-joint exoskeleton. Changes of cortical physiology during the task might also help to make subject-specific adjustments of task difficulty and guide adjunct interventions to facilitate motor learning for functional restoration.

  19. Application of a Dual-Arm Robot in Complex Sample Preparation and Measurement Processes.

    Science.gov (United States)

    Fleischer, Heidi; Drews, Robert Ralf; Janson, Jessica; Chinna Patlolla, Bharath Reddy; Chu, Xianghua; Klos, Michael; Thurow, Kerstin

    2016-10-01

    Automation systems with applied robotics have already been established in industrial applications for many years. In the field of life sciences, a comparable high level of automation can be found in the areas of bioscreening and high-throughput screening. Strong deficits still exist in the development of flexible and universal fully automated systems in the field of analytical measurement. Reasons are the heterogeneous processes with complex structures, which include sample preparation and transport, analytical measurements using complex sensor systems, and suitable data analysis and evaluation. Furthermore, the use of nonstandard sample vessels with various shapes and volumes results in an increased complexity. The direct use of existing automation solutions from bioscreening applications is not possible. A flexible automation system for sample preparation, analysis, and data evaluation is presented in this article. It is applied for the determination of cholesterol in biliary endoprosthesis using gas chromatography-mass spectrometry (GC-MS). A dual-arm robot performs both transport and active manipulation tasks to ensure human-like operation. This general robotic concept also enables the use of manual laboratory devices and equipment and is thus suitable in areas with a high standardization grade. © 2016 Society for Laboratory Automation and Screening.

  20. Multi-arm multilateral haptics-based immersive tele-robotic system (HITS) for improvised explosive device disposal

    Science.gov (United States)

    Erickson, David; Lacheray, Hervé; Lai, Gilbert; Haddadi, Amir

    2014-06-01

    This paper presents the latest advancements of the Haptics-based Immersive Tele-robotic System (HITS) project, a next generation Improvised Explosive Device (IED) disposal (IEDD) robotic interface containing an immersive telepresence environment for a remotely-controlled three-articulated-robotic-arm system. While the haptic feedback enhances the operator's perception of the remote environment, a third teleoperated dexterous arm, equipped with multiple vision sensors and cameras, provides stereo vision with proper visual cues, and a 3D photo-realistic model of the potential IED. This decentralized system combines various capabilities including stable and scaled motion, singularity avoidance, cross-coupled hybrid control, active collision detection and avoidance, compliance control and constrained motion to provide a safe and intuitive control environment for the operators. Experimental results and validation of the current system are presented through various essential IEDD tasks. This project demonstrates that a two-armed anthropomorphic Explosive Ordnance Disposal (EOD) robot interface can achieve complex neutralization techniques against realistic IEDs without the operator approaching at any time.

  1. Design and implementation of a training strategy in chronic stroke with an arm robotic exoskeleton.

    Science.gov (United States)

    Frisoli, Antonio; Sotgiu, Edoardo; Procopio, Caterina; Bergamasco, Massimo; Rossi, Bruno; Chisari, Carmelo

    2011-01-01

    The distinguishing features of active exoskeletons are the capability of guiding arm movement at the level of the full kinematic chain of the human arm, and training full 3D spatial movements. We have specifically developed a PD sliding mode control for upper limb rehabilitation with gain scheduling for providing "assistance as needed", according to the force capability of the patient, and an automatic measurement of the impaired arm joint torques, to evaluate the hypertonia associated to the movement during the execution of the training exercise. Two different training tasks in Virtual Reality were devised, that make use of the above control, and allow to make a performance based evaluation of patient's motor status. The PERCRO L-Exos (Light-Exoskeleton) was used to evaluate the proposed algorithms and training exercises in two clinical case studies of patients with chronic stroke, that performed 6 weeks of robotic assisted training. Clinical evaluation (Fugl-Meyer Scale, Modified Ashworth Scale, Bimanual Activity Test) was conducted before and after treatment and compared to the scores and the quantitative indices, such as task time, position/joint error and resistance torques, associated to the training exercises. © 2011 IEEE

  2. Design of a Lightweight Soft Robotic Arm Using Pneumatic Artificial Muscles and Inflatable Sleeves.

    Science.gov (United States)

    Ohta, Preston; Valle, Luis; King, Jonathan; Low, Kevin; Yi, Jaehyun; Atkeson, Christopher G; Park, Yong-Lae

    2018-04-01

    As robots begin to interact with humans and operate in human environments, safety becomes a major concern. Conventional robots, although reliable and consistent, can cause injury to anyone within its range of motion. Soft robotics, wherein systems are made to be soft and mechanically compliant, are thus a promising alternative due to their lightweight nature and ability to cushion impacts, but current designs often sacrifice accuracy and usefulness for safety. We, therefore, have developed a bioinspired robotic arm combining elements of rigid and soft robotics such that it exhibits the positive qualities of both, namely compliance and accuracy, while maintaining a low weight. This article describes the design of a robotic arm-wrist-hand system with seven degrees of freedom (DOFs). The shoulder and elbow each has two DOFs for two perpendicular rotational motions on each joint, and the hand has two DOFs for wrist rotations and one DOF for a grasp motion. The arm is pneumatically powered using custom-built McKibben type pneumatic artificial muscles, which are inflated and deflated using binary and proportional valves. The wrist and hand motions are actuated through servomotors. In addition to the actuators, the arm is equipped with a potentiometer in each joint for detecting joint angle changes. Simulation and experimental results for closed-loop position control are also presented in the article.

  3. A New Artificial Neural Network Approach in Solving Inverse Kinematics of Robotic Arm (Denso VP6242).

    Science.gov (United States)

    Almusawi, Ahmed R J; Dülger, L Canan; Kapucu, Sadettin

    2016-01-01

    This paper presents a novel inverse kinematics solution for robotic arm based on artificial neural network (ANN) architecture. The motion of robotic arm is controlled by the kinematics of ANN. A new artificial neural network approach for inverse kinematics is proposed. The novelty of the proposed ANN is the inclusion of the feedback of current joint angles configuration of robotic arm as well as the desired position and orientation in the input pattern of neural network, while the traditional ANN has only the desired position and orientation of the end effector in the input pattern of neural network. In this paper, a six DOF Denso robotic arm with a gripper is controlled by ANN. The comprehensive experimental results proved the applicability and the efficiency of the proposed approach in robotic motion control. The inclusion of current configuration of joint angles in ANN significantly increased the accuracy of ANN estimation of the joint angles output. The new controller design has advantages over the existing techniques for minimizing the position error in unconventional tasks and increasing the accuracy of ANN in estimation of robot's joint angles.

  4. A New Artificial Neural Network Approach in Solving Inverse Kinematics of Robotic Arm (Denso VP6242)

    Science.gov (United States)

    Dülger, L. Canan; Kapucu, Sadettin

    2016-01-01

    This paper presents a novel inverse kinematics solution for robotic arm based on artificial neural network (ANN) architecture. The motion of robotic arm is controlled by the kinematics of ANN. A new artificial neural network approach for inverse kinematics is proposed. The novelty of the proposed ANN is the inclusion of the feedback of current joint angles configuration of robotic arm as well as the desired position and orientation in the input pattern of neural network, while the traditional ANN has only the desired position and orientation of the end effector in the input pattern of neural network. In this paper, a six DOF Denso robotic arm with a gripper is controlled by ANN. The comprehensive experimental results proved the applicability and the efficiency of the proposed approach in robotic motion control. The inclusion of current configuration of joint angles in ANN significantly increased the accuracy of ANN estimation of the joint angles output. The new controller design has advantages over the existing techniques for minimizing the position error in unconventional tasks and increasing the accuracy of ANN in estimation of robot's joint angles. PMID:27610129

  5. Digital Hardware Realization of Forward and Inverse Kinematics for a Five-Axis Articulated Robot Arm

    Directory of Open Access Journals (Sweden)

    Bui Thi Hai Linh

    2015-01-01

    Full Text Available When robot arm performs a motion control, it needs to calculate a complicated algorithm of forward and inverse kinematics which consumes much CPU time and certainty slows down the motion speed of robot arm. Therefore, to solve this issue, the development of a hardware realization of forward and inverse kinematics for an articulated robot arm is investigated. In this paper, the formulation of the forward and inverse kinematics for a five-axis articulated robot arm is derived firstly. Then, the computations algorithm and its hardware implementation are described. Further, very high speed integrated circuits hardware description language (VHDL is applied to describe the overall hardware behavior of forward and inverse kinematics. Additionally, finite state machine (FSM is applied for reducing the hardware resource usage. Finally, for verifying the correctness of forward and inverse kinematics for the five-axis articulated robot arm, a cosimulation work is constructed by ModelSim and Simulink. The hardware of the forward and inverse kinematics is run by ModelSim and a test bench which generates stimulus to ModelSim and displays the output response is taken in Simulink. Under this design, the forward and inverse kinematics algorithms can be completed within one microsecond.

  6. The potential of laser cutting and snake arm robots in aspects of nuclear decommissioning

    International Nuclear Information System (INIS)

    Hilton, Paul; Khan, Ali

    2013-01-01

    This paper will describe recent work conducted in the UK to highlight the potential of applying high power laser cutting to aspects of decommissioning and dismantling in the nuclear sector. A major driver for this activity is size reduction of metallic structures, vessels and tubing, with the objective of efficient stacking of the cut parts for future long term storage. TWI have used a standard 5 kW multi-mode laser with fibre optic delivery of the beam, to demonstrate techniques for cutting stainless steel tubing, at diameters up to 150 mm and wall thicknesses up to 7 mm, and various thicknesses of plate materials. Using specially developed cutting heads, employing long focal length lenses to form the beam, techniques were developed to allow the cutting of tubes from one side only and without changing the focal position of the laser beam with respect to the diameter of the tube perpendicular to the incident beam. The latter means that remote programming of the cutting path becomes much simpler. For cutting plate materials, special gas nozzle dynamics have produced great tolerance of the cutting process to stand-off distance (the distance between the surface of the material being cut and the exit of the cutting nozzle). One particularly interesting method of remote deployment of these cutting techniques is to use 'snake arm' robots. These robots, by nature of their construction, can access areas un-accessible using other techniques. This of course makes them particularly suited to aspects of nuclear decommissioning, particularly in what are termed 'un-structured environments', where the exact disposition of items encountered is not known. The paper will also describe the first time a laser cutting head has been installed on the end of a snake arm robot and the combination used in a simulated nuclear cutting application. (author)

  7. Internet remote control interface for a multipurpose robotic arm

    Directory of Open Access Journals (Sweden)

    Matthew W. Dunnigan

    2008-11-01

    Full Text Available This paper presents an Internet remote control interface for a MITSUBISHI PA10-6CE manipulator established for the purpose of the ROBOT museum exhibition during spring and summer 2004. The robotic manipulator is a part of the Intelligent Robotic Systems Laboratory at Heriot ? Watt University, which has been established to work on dynamic and kinematic aspects of manipulator control in the presence of environmental disturbances. The laboratory has been enriched by a simple vision system consisting of three web-cameras to broadcast the live images of the robots over the Internet. The Interface comprises of the TCP/IP server providing command parsing and execution using the open controller architecture of the manipulator and a client Java applet web-site providing a simple robot control interface.

  8. Learning robotic eye-arm-hand coordination from human demonstration: a coupled dynamical systems approach.

    Science.gov (United States)

    Lukic, Luka; Santos-Victor, José; Billard, Aude

    2014-04-01

    We investigate the role of obstacle avoidance in visually guided reaching and grasping movements. We report on a human study in which subjects performed prehensile motion with obstacle avoidance where the position of the obstacle was systematically varied across trials. These experiments suggest that reaching with obstacle avoidance is organized in a sequential manner, where the obstacle acts as an intermediary target. Furthermore, we demonstrate that the notion of workspace travelled by the hand is embedded explicitly in a forward planning scheme, which is actively involved in detecting obstacles on the way when performing reaching. We find that the gaze proactively coordinates the pattern of eye-arm motion during obstacle avoidance. This study provides also a quantitative assessment of the coupling between the eye-arm-hand motion. We show that the coupling follows regular phase dependencies and is unaltered during obstacle avoidance. These observations provide a basis for the design of a computational model. Our controller extends the coupled dynamical systems framework and provides fast and synchronous control of the eyes, the arm and the hand within a single and compact framework, mimicking similar control system found in humans. We validate our model for visuomotor control of a humanoid robot.

  9. Effect of Link Flexibility on tip position of a single link robotic arm

    Science.gov (United States)

    Madhusudan Raju, E.; Siva Rama Krishna, L.; Mouli, Y. Sharath Chandra; Nageswara Rao, V.

    2015-12-01

    The flexible robots are widely used in space applications due to their quick response, lower energy consumption, lower overall mass and operation at high speed compared to conventional industrial rigid link robots. These robots are inherently flexible, so that the kinematics of flexible robots can't be solved with rigid body assumptions. The flexibility in links and joints affects end-point positioning accuracy of the robot. It is important to model the link kinematics with precision which in turn simplifies modelling of dynamics of flexible robots. The main objective of this paper is to evaluate the effect of link flexibility on a tip position of a single link robotic arm for a given motion. The joint is assumed to be rigid and only link flexibility is considered. The kinematics of flexible link problem is evaluated by Assumed Modes Method (AMM) using MAT LAB Programming. To evaluate the effect of link flexibility (with and without payload) of robotic arm, the normalized tip deviation is found for flexible link with respect to a rigid link. Finally, the limiting inertia for payload mass is found if the allowable tip deviation is 5%.

  10. Optimum Design of Multi-Function Robot Arm Gripper for Varying Shape Green Product

    Directory of Open Access Journals (Sweden)

    Razali Zol Bahri

    2016-01-01

    Full Text Available The project focuses on thorough experimentally studies of the optimum design of Multi-function Robot Arm Gripper for varying shape green product. The purpose of this project is to design a few of robot arm gripper for multi-functionally grip a green product with varying shape. The main character of the gripper is that it can automated adjust its finger to suit with the shape of the product. An optimum design of multi-function robot arm gripper is verified through experimental study. The expected result is a series of analytical results on the proposal of gripper design and material that will be selected for the gripper. The analysis of the gripper design proposal by using ANSYS and CATIA software is described in detail in this paper.

  11. Integration of a Robotic Arm with the Surgical Assistant Workstation Software Framework

    OpenAIRE

    Young, J.; Elhawary, H.; Popovic, A.

    2012-01-01

    We have integrated the Philips Research robot arm with the Johns Hopkins University cisst library, an open-source platform for computerassisted surgical intervention. The development of a Matlab to C++ wrapper to abstract away servo-level details facilitates the rapid development of a component-based framework with “plug and play” features. This allows the user to easily exchange the robot with an alternative manipulator while maintaining the same overall functionality.

  12. Compliance Modeling and Error Compensation of a 3-Parallelogram Lightweight Robotic Arm

    DEFF Research Database (Denmark)

    Wu, Guanglei; Guo, Sheng; Bai, Shaoping

    2015-01-01

    This paper presents compliance modeling and error compensation for lightweight robotic arms built with parallelogram linkages, i.e., Π joints. The Cartesian stiffness matrix is derived using the virtual joint method. Based on the developed stiffness model, a method to compensate the compliance...... error is introduced, being illustrated with a 3-parallelogram robot in the application of pick-and-place operation. The results show that this compensation method can effectively improve the operation accuracy....

  13. A New Artificial Neural Network Approach in Solving Inverse Kinematics of Robotic Arm (Denso VP6242

    Directory of Open Access Journals (Sweden)

    Ahmed R. J. Almusawi

    2016-01-01

    Full Text Available This paper presents a novel inverse kinematics solution for robotic arm based on artificial neural network (ANN architecture. The motion of robotic arm is controlled by the kinematics of ANN. A new artificial neural network approach for inverse kinematics is proposed. The novelty of the proposed ANN is the inclusion of the feedback of current joint angles configuration of robotic arm as well as the desired position and orientation in the input pattern of neural network, while the traditional ANN has only the desired position and orientation of the end effector in the input pattern of neural network. In this paper, a six DOF Denso robotic arm with a gripper is controlled by ANN. The comprehensive experimental results proved the applicability and the efficiency of the proposed approach in robotic motion control. The inclusion of current configuration of joint angles in ANN significantly increased the accuracy of ANN estimation of the joint angles output. The new controller design has advantages over the existing techniques for minimizing the position error in unconventional tasks and increasing the accuracy of ANN in estimation of robot’s joint angles.

  14. Design a Fuzzy Logic Controller for a Rotary Flexible Joint Robotic Arm

    Directory of Open Access Journals (Sweden)

    Jalani Jamaludin

    2018-01-01

    Full Text Available The purpose of this research is to design a fuzzy logic feedback controller (FLC in order to control a desired tip angle position a rotary flexible joint robotic arm. The FLC is also employed to dampen the vibration emanated from a rotary flexible joint robotic arm when reaching a desired tip angle position. The performance of FLC is tested in simulation and experiment. It is found that the FLC is successfully designed, applied and tested. The results show that fuzzy logic controller performed satisfactorily control a desired tip angle position and reduce the oscillations.

  15. Computer coordination of limb motion for locomotion of a multiple-armed robot for space assembly

    Science.gov (United States)

    Klein, C. A.; Patterson, M. R.

    1982-01-01

    Consideration is given to a possible robotic system for the construction of large space structures, which may be described as a multiple general purpose arm manipulator vehicle that can walk over the structure under construction to a given site for further work. A description is presented of the locomotion of such a vehicle, modeling its arms in terms of a currently available industrial manipulator. It is noted that for whatever maximum speed of operation is chosen, rapid changes in robot velocity create situations in which already-selected handholds are no longer practical. A step is added to the 'free gait' walking algorithm in order to solve this problem.

  16. Three-dimensional neural net for learning visuomotor coordination of a robot arm.

    Science.gov (United States)

    Martinetz, T M; Ritter, H J; Schulten, K J

    1990-01-01

    An extension of T. Kohonen's (1982) self-organizing mapping algorithm together with an error-correction scheme based on the Widrow-Hoff learning rule is applied to develop a learning algorithm for the visuomotor coordination of a simulated robot arm. Learning occurs by a sequence of trial movements without the need for an external teacher. Using input signals from a pair of cameras, the closed robot arm system is able to reduce its positioning error to about 0.3% of the linear dimensions of its work space. This is achieved by choosing the connectivity of a three-dimensional lattice consisting of the units of the neural net.

  17. Design optimization on the drive train of a light-weight robotic arm

    DEFF Research Database (Denmark)

    Zhou, Lelai; Bai, Shaoping; Hansen, Michael Rygaard

    2011-01-01

    A drive train optimization method for design of light-weight robots is proposed. Optimal selections of motors and gearboxes from a limited catalog of commercially available components are done simultaneously for all joints of a robotic arm. Characteristics of the motor and gearbox, including gear...... ratio, gear inertia, motor inertia, and gear efficiency, are considered in the drive train modeling. A co-simulation method is developed for dynamic simulation of the arm. A design example is included to demonstrate the proposed design optimization method....

  18. Investigation of the Impedance Characteristic of Human Arm for Development of Robots to Cooperate with Humans

    Science.gov (United States)

    Rahman, Md. Mozasser; Ikeura, Ryojun; Mizutani, Kazuki

    In the near future many aspects of our lives will be encompassed by tasks performed in cooperation with robots. The application of robots in home automation, agricultural production and medical operations etc. will be indispensable. As a result robots need to be made human-friendly and to execute tasks in cooperation with humans. Control systems for such robots should be designed to work imitating human characteristics. In this study, we have tried to achieve these goals by means of controlling a simple one degree-of-freedom cooperative robot. Firstly, the impedance characteristic of the human arm in a cooperative task is investigated. Then, this characteristic is implemented to control a robot in order to perform cooperative task with humans. A human followed the motion of an object, which is moved through desired trajectories. The motion is actuated by the linear motor of the one degree-of-freedom robot system. Trajectories used in the experiments of this method were minimum jerk (the rate of change of acceleration) trajectory, which was found during human and human cooperative task and optimum for muscle movement. As the muscle is mechanically analogous to a spring-damper system, a simple second-order equation is used as models for the arm dynamics. In the model, we considered mass, stiffness and damping factor. Impedance parameter is calculated from the position and force data obtained from the experiments and based on the “Estimation of Parametric Model”. Investigated impedance characteristic of human arm is then implemented to control a robot, which performed cooperative task with human. It is observed that the proposed control methodology has given human like movements to the robot for cooperating with human.

  19. Managing the backscatter component from the robotic arm of an a-Si EPID

    International Nuclear Information System (INIS)

    Lee, C.G.; Menk, F.; Greer, P.B.

    2010-01-01

    Full text: Backscatter from the robotic arm mechanism of an a-Si EPID in IMRT images was examined. Images corrected with a conventional flood field (FF) containing a backscatter component (BSC) from the robotic ann were compared with a BSC-free FF. A Yarian 21 EX linac (6 MV, 18 MV) was used. All images were acquired with two aS500 EPIDs, one R-arm and one E-arm. The BSC of an EPID image is the ratio of an image acquired with the EPID attached to the arm then detaching the arm from the EPID and acquiring the same image. A range of square field sizes from 2.5 x 2.5 cm to 27.5 x 27.5 cm were acquired and the BSC analyzed. The BSC of the FFs were also measured. A series of IMRT fields were acquired. Each field was corrected with a conventional FF and compared with a BSC-free FF. Figure I shows the magnitude of the BSC from each arm in the inplane for a 6 x beam. Square fields above 16 x l6 cm (R-arm) and lO x 10 cm (E-arm) benefited from a conventional FF as it tended to cancel out the BSC in the acquired square field. The opposite was observed for smaller field sizes. A gamma analysis of the IMRT fields showed a FF correction containing a BSC reduces the effect of the arm in the final image. IMRT EPID images using conventional FFs have been shown to be less affected by backscatter from the robotic arm compared to BSC-free flood fields. (author)

  20. Robotically facilitated virtual rehabilitation of arm transport integrated with finger movement in persons with hemiparesis

    OpenAIRE

    Davidow Amy; Lafond Ian; Saleh Soha; Qiu Qinyin; Fluet Gerard G; Merians Alma S; Adamovich Sergei V

    2011-01-01

    Abstract Background Recovery of upper extremity function is particularly recalcitrant to successful rehabilitation. Robotic-assisted arm training devices integrated with virtual targets or complex virtual reality gaming simulations are being developed to deal with this problem. Neural control mechanisms indicate that reaching and hand-object manipulation are interdependent, suggesting that training on tasks requiring coordinated effort of both the upper arm and hand may be a more effective me...

  1. An innovative approach for modeling and simulation of an automated industrial robotic arm operated electro-pneumatically

    Science.gov (United States)

    Popa, L.; Popa, V.

    2017-08-01

    The article is focused on modeling an automated industrial robotic arm operated electro-pneumatically and to simulate the robotic arm operation. It is used the graphic language FBD (Function Block Diagram) to program the robotic arm on Zelio Logic automation. The innovative modeling and simulation procedures are considered specific problems regarding the development of a new type of technical products in the field of robotics. Thus, were identified new applications of a Programmable Logic Controller (PLC) as a specialized computer performing control functions with a variety of high levels of complexit.

  2. Biologically inspired control of humanoid robot arms robust and adaptive approaches

    CERN Document Server

    Spiers, Adam; Herrmann, Guido

    2016-01-01

    This book investigates a biologically inspired method of robot arm control, developed with the objective of synthesising human-like motion dynamically, using nonlinear, robust and adaptive control techniques in practical robot systems. The control method caters to a rising interest in humanoid robots and the need for appropriate control schemes to match these systems. Unlike the classic kinematic schemes used in industrial manipulators, the dynamic approaches proposed here promote human-like motion with better exploitation of the robot’s physical structure. This also benefits human-robot interaction. The control schemes proposed in this book are inspired by a wealth of human-motion literature that indicates the drivers of motion to be dynamic, model-based and optimal. Such considerations lend themselves nicely to achievement via nonlinear control techniques without the necessity for extensive and complex biological models. The operational-space method of robot control forms the basis of many of the techniqu...

  3. Soft-robotic arm inspired by the octopus: II. From artificial requirements to innovative technological solutions

    International Nuclear Information System (INIS)

    Mazzolai, B; Margheri, L; Cianchetti, M; Dario, P; Laschi, C

    2012-01-01

    Soft robotics is a current focus in robotics research because of the expected capability of soft robots to better interact with real-world environments. As a point of inspiration in the development of innovative technologies in soft robotics, octopuses are particularly interesting ‘animal models’. Octopus arms have unique biomechanical capabilities that combine significant pliability with the ability to exert a great deal of force, because they lack rigid structures but can change and control their degree of stiffness. The octopus arm motor capability is a result of the peculiar arrangement of its muscles and the properties of its tissues. These special abilities have been investigated by the authors in a specific study dedicated to identifying the key principles underlying these biological functions and deriving engineering requirements for robotics solutions. This paper, which is the second in a two-part series, presents how the identified requirements can be used to create innovative technological solutions, such as soft materials, mechanisms and actuators. Experiments indicate the ability of these proposed solutions to ensure the same performance as in the biological model in terms of compliance, elongation and force. These results represent useful and relevant components of innovative soft-robotic systems and suggest their potential use to create a new generation of highly dexterous, soft-bodied robots. (paper)

  4. Trajectory control of an articulated robot with a parallel drive arm based on splines under tension

    Science.gov (United States)

    Yi, Seung-Jong

    Today's industrial robots controlled by mini/micro computers are basically simple positioning devices. The positioning accuracy depends on the mathematical description of the robot configuration to place the end-effector at the desired position and orientation within the workspace and on following the specified path which requires the trajectory planner. In addition, the consideration of joint velocity, acceleration, and jerk trajectories are essential for trajectory planning of industrial robots to obtain smooth operation. The newly designed 6 DOF articulated robot with a parallel drive arm mechanism which permits the joint actuators to be placed in the same horizontal line to reduce the arm inertia and to increase load capacity and stiffness is selected. First, the forward kinematic and inverse kinematic problems are examined. The forward kinematic equations are successfully derived based on Denavit-Hartenberg notation with independent joint angle constraints. The inverse kinematic problems are solved using the arm-wrist partitioned approach with independent joint angle constraints. Three types of curve fitting methods used in trajectory planning, i.e., certain degree polynomial functions, cubic spline functions, and cubic spline functions under tension, are compared to select the best possible method to satisfy both smooth joint trajectories and positioning accuracy for a robot trajectory planner. Cubic spline functions under tension is the method selected for the new trajectory planner. This method is implemented for a 6 DOF articulated robot with a parallel drive arm mechanism to improve the smoothness of the joint trajectories and the positioning accuracy of the manipulator. Also, this approach is compared with existing trajectory planners, 4-3-4 polynomials and cubic spline functions, via circular arc motion simulations. The new trajectory planner using cubic spline functions under tension is implemented into the microprocessor based robot controller and

  5. Modeling and identification for high-performance robot control : an RRR-robotic arm case study

    NARCIS (Netherlands)

    Kostic, D.; Jager, de A.G.; Steinbuch, M.; Hensen, R.H.A.

    2004-01-01

    We explain a procedure for getting models of robot kinematics and dynamics that are appropriate for robot control design. The procedure consists of the following steps: (i) derivation of robot kinematic and dynamic models and establishing correctness of their structures; (ii) experimental estimation

  6. Exploiting Dynamics in robotic arms with repetitive tasks

    NARCIS (Netherlands)

    Plooij, M.C.

    2015-01-01

    Since the industrial revolution, machines have taken over many tasks from humans, increasing labor productivity and prosperity. In the 20th century, the introduction of robots created a second wave of automation, increasing the labor productivity even further. In order to create a third wave of

  7. Robotics combined with electrical stimulation : hybrid support of arm and hand for functional training after stroke

    NARCIS (Netherlands)

    Westerveld, Ard

    2014-01-01

    Reach, grasp and release is part of many functional movements. Graying of society leads to more stroke victims and fewer health care professionals. Technology might be a solution to support certain rehabilitation therapies in future health care. Robotic systems have been developed for support of arm

  8. Robotics combined with electrical stimulation: hybrid support of arm and hand for functional training after stroke

    NARCIS (Netherlands)

    Westerveld, Ard

    2014-01-01

    Reach, grasp and release is part of many functional movements. Graying of society leads to more stroke victims and fewer health care professionals. Technology might be a solution to support certain rehabilitation therapies in future health care. Robotic systems have been developed for support of arm

  9. Integration of a Robotic Arm with the Surgical Assistant Workstation Software Framework

    NARCIS (Netherlands)

    Young, J.; Elhawary, H.; Popovic, A.

    2012-01-01

    We have integrated the Philips Research robot arm with the Johns Hopkins University cisst library, an open-source platform for computerassisted surgical intervention. The development of a Matlab to C++ wrapper to abstract away servo-level details facilitates the rapid development of a

  10. Extended Kalman filtering applied to a two-axis robotic arm with flexible links

    Energy Technology Data Exchange (ETDEWEB)

    Lertpiriyasuwat, V.; Berg, M.C.; Buffinton, K.W.

    2000-03-01

    An industrial robot today uses measurements of its joint positions and models of its kinematics and dynamics to estimate and control its end-effector position. Substantially better end-effector position estimation and control performance would be obtainable if direct measurements of its end-effector position were also used. The subject of this paper is extended Kalman filtering for precise estimation of the position of the end-effector of a robot using, in addition to the usual measurements of the joint positions, direct measurements of the end-effector position. The estimation performances of extended Kalman filters are compared in applications to a planar two-axis robotic arm with very flexible links. The comparisons shed new light on the dependence of extended Kalman filter estimation performance on the quality of the model of the arm dynamics that the extended Kalman filter operates with.

  11. MAHLI on Mars: lessons learned operating a geoscience camera on a landed payload robotic arm

    Science.gov (United States)

    Aileen Yingst, R.; Edgett, Kenneth S.; Kennedy, Megan R.; Krezoski, Gillian M.; McBride, Marie J.; Minitti, Michelle E.; Ravine, Michael A.; Williams, Rebecca M. E.

    2016-06-01

    The Mars Hand Lens Imager (MAHLI) is a 2-megapixel, color camera with resolution as high as 13.9 µm pixel-1. MAHLI has operated successfully on the Martian surface for over 1150 Martian days (sols) aboard the Mars Science Laboratory (MSL) rover, Curiosity. During that time MAHLI acquired images to support science and science-enabling activities, including rock and outcrop textural analysis; sand characterization to further the understanding of global sand properties and processes; support of other instrument observations; sample extraction site documentation; range-finding for arm and instrument placement; rover hardware and instrument monitoring and safety; terrain assessment; landscape geomorphology; and support of rover robotic arm commissioning. Operation of the instrument has demonstrated that imaging fully illuminated, dust-free targets yields the best results, with complementary information obtained from shadowed images. The light-emitting diodes (LEDs) allow satisfactory night imaging but do not improve daytime shadowed imaging. MAHLI's combination of fine-scale, science-driven resolution, RGB color, the ability to focus over a large range of distances, and relatively large field of view (FOV), have maximized the return of science and science-enabling observations given the MSL mission architecture and constraints.

  12. The preliminary of software development for the kinematics analysis of 5 DOF Nuclear Malaysia robot arm v2

    International Nuclear Information System (INIS)

    Mohd Zaid Hassan; Anwar Abdul Rahman; Rosli Darmawan; Mohd Arif Hamzah

    2010-01-01

    This paper presents the preliminary software development for the kinematics analysis of 5 DOF rescue robot. The kinematics analysis is the study of relationship between the individual joints of the robot manipulator, the position and orientation of the end-effector. The Denavit-Hartenberg (DH) model is used to model the robot links and joints. Both forward and inverse kinematic are presented. The simulation software has been developed by using MATLAB to solve the robot arms kinematic behavior. (author)

  13. Pedicle Screw Insertion Accuracy Using O-Arm, Robotic Guidance, or Freehand Technique: A Comparative Study.

    Science.gov (United States)

    Laudato, Pietro Aniello; Pierzchala, Katarzyna; Schizas, Constantin

    2018-03-15

    A retrospective radiological study. The aim of this study was to evaluate the accuracy of pedicle screw insertion using O-Arm navigation, robotic assistance, or a freehand fluoroscopic technique. Pedicle screw insertion using either "O-Arm" navigation or robotic devices is gaining popularity. Although several studies are available evaluating each of those techniques separately, no direct comparison has been attempted. Eighty-four patients undergoing implantation of 569 lumbar and thoracic screws were divided into three groups. Eleven patients (64 screws) had screws inserted using robotic assistance, 25 patients (191 screws) using the O-arm, while 48 patients (314 screws) had screws inserted using lateral fluoroscopy in a freehand technique. A single experienced spine surgeon assisted by a spinal fellow performed all procedures. Screw placement accuracy was assessed by two independent observers on postoperative computed tomography (CTs) according to the A to D Rampersaud criteria. No statistically significant difference was noted between the three groups. About 70.4% of screws in the freehand group, 69.6% in the O arm group, and 78.8% in the robotic group were placed completely within the pedicle margins (grade A) (P > 0.05). About 6.4% of screws were considered misplaced (grades C&D) in the freehand group, 4.2% in the O-arm group, and 4.7% in the robotic group (P > 0.05). The spinal fellow inserted screws with the same accuracy as the senior surgeon (P > 0.05). The advent of new technologies does not appear to alter accuracy of screw placement in our setting. Under supervision, spinal fellows might perform equally well to experienced surgeons using new tools. The lack of difference in accuracy does not imply that the above-mentioned techniques have no added advantages. Other issues, such as surgeon/patient radiation, fiddle factor, teaching suitability, etc., outside the scope of our present study, need further assessment. 3.

  14. Soft robotic arm inspired by the octopus: I. From biological functions to artificial requirements

    International Nuclear Information System (INIS)

    Margheri, L; Laschi, C; Mazzolai, B

    2012-01-01

    Octopuses are molluscs that belong to the group Cephalopoda. They lack joints and rigid links, and as a result, their arms possess virtually limitless freedom of movement. These flexible appendages exhibit peculiar biomechanical features such as stiffness control, compliance, and high flexibility and dexterity. Studying the capabilities of the octopus arm is a complex task that presents a challenge for both biologists and roboticists, the latter of whom draw inspiration from the octopus in designing novel technologies within soft robotics. With this idea in mind, in this study, we used new, purposively developed methods of analysing the octopus arm in vivo to create new biologically inspired design concepts. Our measurements showed that the octopus arm can elongate by 70% in tandem with a 23% diameter reduction and exhibits an average pulling force of 40 N. The arm also exhibited a 20% mean shortening at a rate of 17.1 mm s −1 and a longitudinal stiffening rate as high as 2 N (mm s) −1 . Using histology and ultrasounds, we investigated the functional morphology of the internal tissues, including the sinusoidal arrangement of the nerve cord and the local insertion points of the longitudinal and transverse muscle fibres. The resulting information was used to create novel design principles and specifications that can in turn be used in developing a new soft robotic arm. (paper)

  15. Soft robotic arm inspired by the octopus: I. From biological functions to artificial requirements.

    Science.gov (United States)

    Margheri, L; Laschi, C; Mazzolai, B

    2012-06-01

    Octopuses are molluscs that belong to the group Cephalopoda. They lack joints and rigid links, and as a result, their arms possess virtually limitless freedom of movement. These flexible appendages exhibit peculiar biomechanical features such as stiffness control, compliance, and high flexibility and dexterity. Studying the capabilities of the octopus arm is a complex task that presents a challenge for both biologists and roboticists, the latter of whom draw inspiration from the octopus in designing novel technologies within soft robotics. With this idea in mind, in this study, we used new, purposively developed methods of analysing the octopus arm in vivo to create new biologically inspired design concepts. Our measurements showed that the octopus arm can elongate by 70% in tandem with a 23% diameter reduction and exhibits an average pulling force of 40 N. The arm also exhibited a 20% mean shortening at a rate of 17.1 mm s(-1) and a longitudinal stiffening rate as high as 2 N (mm s)(-1). Using histology and ultrasounds, we investigated the functional morphology of the internal tissues, including the sinusoidal arrangement of the nerve cord and the local insertion points of the longitudinal and transverse muscle fibres. The resulting information was used to create novel design principles and specifications that can in turn be used in developing a new soft robotic arm.

  16. Augmented reality user interface for mobile ground robots with manipulator arms

    Science.gov (United States)

    Vozar, Steven; Tilbury, Dawn M.

    2011-01-01

    Augmented Reality (AR) is a technology in which real-world visual data is combined with an overlay of computer graphics, enhancing the original feed. AR is an attractive tool for teleoperated UGV UIs as it can improve communication between robots and users via an intuitive spatial and visual dialogue, thereby increasing operator situational awareness. The successful operation of UGVs often relies upon both chassis navigation and manipulator arm control, and since existing literature usually focuses on one task or the other, there is a gap in mobile robot UIs that take advantage of AR for both applications. This work describes the development and analysis of an AR UI system for a UGV with an attached manipulator arm. The system supplements a video feed shown to an operator with information about geometric relationships within the robot task space to improve the operator's situational awareness. Previous studies on AR systems and preliminary analyses indicate that such an implementation of AR for a mobile robot with a manipulator arm is anticipated to improve operator performance. A full user-study can determine if this hypothesis is supported by performing an analysis of variance on common test metrics associated with UGV teleoperation.

  17. The Microsoft Visual Studio Software Development For 5 DOF Nuclear Malaysia Robot Arm V2 Control System

    International Nuclear Information System (INIS)

    Mohd Zaid Hassan; Anwar Abdul Rahman; Azraf Azman; Mohd Rizal Mamat; Mohd Arif Hamzah

    2014-01-01

    This paper presents the Microsoft visual studio development for 5DOF Nuclear Malaysia Robot Arm V2 control system. The kinematics analysis is the study of the relationship between the individual joints of robot manipulator, the position and orientation of the end-effector. The Denavit-Hartenberg (DH) model is used to model the robot links and joints. Both forward and inverse kinematic are presented. The simulation software has been developed by using Microsoft visual studio to solve the robot arms kinematic behavior. (author)

  18. Whole-arm tactile sensing for beneficial and acceptable contact during robotic assistance.

    Science.gov (United States)

    Grice, Phillip M; Killpack, Marc D; Jain, Advait; Vaish, Sarvagya; Hawke, Jeffrey; Kemp, Charles C

    2013-06-01

    Many assistive tasks involve manipulation near the care-receiver's body, including self-care tasks such as dressing, feeding, and personal hygiene. A robot can provide assistance with these tasks by moving its end effector to poses near the care-receiver's body. However, perceiving and maneuvering around the care-receiver's body can be challenging due to a variety of issues, including convoluted geometry, compliant materials, body motion, hidden surfaces, and the object upon which the body is resting (e.g., a wheelchair or bed). Using geometric simulations, we first show that an assistive robot can achieve a much larger percentage of end-effector poses near the care-receiver's body if its arm is allowed to make contact. Second, we present a novel system with a custom controller and whole-arm tactile sensor array that enables a Willow Garage PR2 to regulate contact forces across its entire arm while moving its end effector to a commanded pose. We then describe tests with two people with motor impairments, one of whom used the system to grasp and pull a blanket over himself and to grab a cloth and wipe his face, all while in bed at his home. Finally, we describe a study with eight able-bodied users in which they used the system to place objects near their bodies. On average, users perceived the system to be safe and comfortable, even though substantial contact occurred between the robot's arm and the user's body.

  19. Right-Arm Robotic-Aided-Therapy with the Light-Exoskeleton: A General Overview

    OpenAIRE

    Lugo-Villeda , Luis I.; Frisoli , Antonio; Sotgiu , Edoardo; Greco , Giovanni; Bergamasco , Massimo; Lugo-Villeda , Luis ,

    2010-01-01

    Part 7: Robots and Manipulation; International audience; Rehabilitation robotics applications and their developments have been spreading out as consequences of the actual needs in the human activities of daily living (ADL). Exoskeletons for rehabilitation are one of them, whose intrinsic characteristics are quite useful for applications where repetitive, robustness and accurate performance are a must. As a part of robotic-mediated-rehabilitation programme into the worldwide, the exoskeletons ...

  20. Constraint optimization model of a scheduling problem for a robotic arm in automatic systems

    DEFF Research Database (Denmark)

    Kristiansen, Ewa; Smith, Stephen F.; Kristiansen, Morten

    2014-01-01

    are characteristics of the painting process application itself. Unlike spot-welding, painting tasks require movement of the entire robot arm. In addition to minimizing intertask duration, the scheduler must strive to maximize painting quality and the problem is formulated as a multi-objective optimization problem....... The scheduling model is implemented as a stand-alone module using constraint programming, and integrated with a larger automatic system. The results of a number of simulation experiments with simple parts are reported, both to characterize the functionality of the scheduler and to illustrate the operation...... of the entire software system for automatic generation of robot programs for painting....

  1. Robot Arm with Tendon Connector Plate and Linear Actuator

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Diftler, Myron A. (Inventor); Bridgwater, Lyndon (Inventor); Nguyen, Vienny (Inventor); Millerman, Alexander (Inventor)

    2014-01-01

    A robotic system includes a tendon-driven end effector, a linear actuator, a flexible tendon, and a plate assembly. The linear actuator assembly has a servo motor and a drive mechanism, the latter of which translates linearly with respect to a drive axis of the servo motor in response to output torque from the servo motor. The tendon connects to the end effector and drive mechanism. The plate assembly is disposed between the linear actuator assembly and the tendon-driven end effector and includes first and second plates. The first plate has a first side that defines a boss with a center opening. The second plate defines an accurate through-slot having tendon guide channels. The first plate defines a through passage for the tendon between the center opening and a second side of the first plate. A looped end of the flexible tendon is received within the tendon guide channels.

  2. Unilateral versus bilateral robot-assisted rehabilitation on arm-trunk control and functions post stroke: a randomized controlled trial.

    Science.gov (United States)

    Wu, Ching-Yi; Yang, Chieh-Ling; Chen, Ming-de; Lin, Keh-Chung; Wu, Li-Ling

    2013-04-12

    Although the effects of robot-assisted arm training after stroke are promising, the relative effects of unilateral (URT) vs. bilateral (BRT) robot-assisted arm training remain uncertain. This study compared the effects of URT vs. BRT on upper extremity (UE) control, trunk compensation, and function in patients with chronic stroke. This was a single-blinded, randomized controlled trial. The intervention was implemented at 4 hospitals. Fifty-three patients with stroke were randomly assigned to URT, BRT, or control treatment (CT). Each group received UE training for 90 to 105 min/day, 5 days/week, for 4 weeks. The kinematic variables for arm motor control and trunk compensation included normalized movement time, normalized movement units, and the arm-trunk contribution slope in unilateral and bilateral tasks. Motor function and daily function were measured by the Wolf Motor Function Test (WMFT), Motor Activity Log (MAL), and ABILHAND Questionnaire. The BRT and CT groups elicited significantly larger slope values (i.e., less trunk compensation) at the start of bilateral reaching than the URT group. URT led to significantly better effects on WMFT-Time than BRT. Differences in arm control kinematics and performance on the MAL and ABILHAND among the 3 groups were not significant. BRT and URT resulted in differential improvements in specific UE/trunk performance in patients with stroke. BRT elicited larger benefits than URT on reducing compensatory trunk movements at the beginning of reaching. In contrast, URT produced better improvements in UE temporal efficiency. These relative effects on movement kinematics, however, did not translate into differential benefits in daily functions. ClinicalTrials.gov: NCT00917605.

  3. Integrating Soft Robotics with the Robot Operating System: A Hybrid Pick and Place Arm

    Directory of Open Access Journals (Sweden)

    Ross M. McKenzie

    2017-08-01

    Full Text Available Soft robotic systems present a variety of new opportunities for solving complex problems. The use of soft robotic grippers, for example, can simplify the complexity in tasks such as the grasping of irregular and delicate objects. Adoption of soft robotics by the informatics community and industry, however, has been slow and this is, in-part, due to the amount of hardware and software that must be developed from scratch for each use of soft system components. In this paper, we detail the design, fabrication, and validation of an open-source framework that we designed to lower the barrier to entry for integrating soft robotic subsystems. This framework is built on the robot operating system (ROS, and we use it to demonstrate a modular, soft–hard hybrid system, which is capable of completing pick and place tasks. By lowering this barrier to entry through our open sourced hardware and software, we hope that system designers and Informatics researchers will find it easy to integrate soft components into their existing ROS-enabled robotic systems.

  4. Space robotics--DLR's telerobotic concepts, lightweight arms and articulated hands.

    Science.gov (United States)

    Hirzinger, G; Brunner, B; Landzettel, K; Sporer, N; Butterfass, J; Schedl, M

    2003-01-01

    The paper briefly outlines DLR's experience with real space robot missions (ROTEX and ETS VII). It then discusses forthcoming projects, e.g., free-flying systems in low or geostationary orbit and robot systems around the space station ISS, where the telerobotic system MARCO might represent a common baseline. Finally it describes our efforts in developing a new generation of "mechatronic" ultra-light weight arms with multifingered hands. The third arm generation is operable now (approaching present-day technical limits). In a similar way DLR's four-fingered hand II was a big step towards higher reliability and yet better performance. Artificial robonauts for space are a central goal now for the Europeans as well as for NASA, and the first verification tests of DLR's joint components are supposed to fly already end of 93 on the space station.

  5. Novel Adaptive Forward Neural MIMO NARX Model for the Identification of Industrial 3-DOF Robot Arm Kinematics

    OpenAIRE

    Ho Pham Huy Anh; Nguyen Thanh Nam

    2012-01-01

    In this paper, a novel forward adaptive neural MIMO NARX model is used for modelling and identifying the forward kinematics of an industrial 3‐DOF robot arm system. The nonlinear features of the forward kinematics of the industrial robot arm drive are thoroughly modelled based on the forward adaptive neural NARX model‐based identification process using experimental input‐output training data. This paper proposes a novel use of a back propagation (BP) algorithm to generate the forward neural M...

  6. A crossover pilot study evaluating the functional outcomes of two different types of robotic movement training in chronic stroke survivors using the arm exoskeleton BONES.

    Science.gov (United States)

    Milot, Marie-Hélène; Spencer, Steven J; Chan, Vicky; Allington, James P; Klein, Julius; Chou, Cathy; Bobrow, James E; Cramer, Steven C; Reinkensmeyer, David J

    2013-12-19

    To date, the limited degrees of freedom (DOF) of most robotic training devices hinders them from providing functional training following stroke. We developed a 6-DOF exoskeleton ("BONES") that allows movement of the upper limb to assist in rehabilitation. The objectives of this pilot study were to evaluate the impact of training with BONES on function of the affected upper limb, and to assess whether multijoint functional robotic training would translate into greater gains in arm function than single joint robotic training also conducted with BONES. Twenty subjects with mild to moderate chronic stroke participated in this crossover study. Each subject experienced multijoint functional training and single joint training three sessions per week, for four weeks, with the order of presentation randomized. The primary outcome measure was the change in Box and Block Test (BBT). The secondary outcome measures were the changes in Fugl-Meyer Arm Motor Scale (FMA), Wolf Motor Function Test (WMFT), Motor Activity Log (MAL), and quantitative measures of strength and speed of reaching. These measures were assessed at baseline, after each training period, and at a 3-month follow-up evaluation session. Training with the robotic exoskeleton resulted in significant improvements in the BBT, FMA, WMFT, MAL, shoulder and elbow strength, and reaching speed (p robotic training programs. However, for the BBT, WMFT and MAL, inequality of carryover effects were noted; subsequent analysis on the change in score between the baseline and first period of training again revealed no difference in the gains obtained between the types of training. Training with the 6 DOF arm exoskeleton improved motor function after chronic stroke, challenging the idea that robotic therapy is only useful for impairment reduction. The pilot results presented here also suggest that multijoint functional robotic training is not decisively superior to single joint robotic training. This challenges the idea that

  7. SpaceWire- Based Control System Architecture for the Lightweight Advanced Robotic Arm Demonstrator [LARAD

    Science.gov (United States)

    Rucinski, Marek; Coates, Adam; Montano, Giuseppe; Allouis, Elie; Jameux, David

    2015-09-01

    The Lightweight Advanced Robotic Arm Demonstrator (LARAD) is a state-of-the-art, two-meter long robotic arm for planetary surface exploration currently being developed by a UK consortium led by Airbus Defence and Space Ltd under contract to the UK Space Agency (CREST-2 programme). LARAD has a modular design, which allows for experimentation with different electronics and control software. The control system architecture includes the on-board computer, control software and firmware, and the communication infrastructure (e.g. data links, switches) connecting on-board computer(s), sensors, actuators and the end-effector. The purpose of the control system is to operate the arm according to pre-defined performance requirements, monitoring its behaviour in real-time and performing safing/recovery actions in case of faults. This paper reports on the results of a recent study about the feasibility of the development and integration of a novel control system architecture for LARAD fully based on the SpaceWire protocol. The current control system architecture is based on the combination of two communication protocols, Ethernet and CAN. The new SpaceWire-based control system will allow for improved monitoring and telecommanding performance thanks to higher communication data rate, allowing for the adoption of advanced control schemes, potentially based on multiple vision sensors, and for the handling of sophisticated end-effectors that require fine control, such as science payloads or robotic hands.

  8. The implementation of common object request broker architecture (CORBA) for controlling robot arm via web

    International Nuclear Information System (INIS)

    Syed Mahamad Zuhdi Amin; Mohd Yazid Idris; Wan Mohd Nasir Wan Kadir

    2001-01-01

    This paper presents the employment of the Common Object Request Broker Architecture (CORBA) technology in the implementation of our distributed Arm Robot Controller (ARC). CORBA is an industrial standard architecture based on distributed abstract object model, which is developed by Object Management Group (OMG). The architecture consists of five components i.e. Object Request Broker (ORB), Interface Definition Language (IDL), Dynamic Invocation Interface (DII), Interface Repositories (IR) and Object adapter (OA). CORBA objects are different from typical programming objects in three ways i.e. they can be executed on any platform, located anywhere on the network and written in any language that supports IDL mapping. In the implementation of the system, 5 degree of freedom (DOF) arm robot RCS 6.0 and Java as a programming mapping to the CORBA IDL. By implementing this architecture, the objects in the server machine can be distributed over the network in order to run the controller. the ultimate goal for our ARC system is to demonstrate concurrent execution of multiple arm robots through multiple instantiations of distributed object components. (Author)

  9. Research regarding the influence of driving-wires length change on positioning precision of a robotic arm

    Science.gov (United States)

    Ciofu, C.; Stan, G.

    2016-08-01

    The paper emphasise positioning precision of an elephant's trunk robotic arm which has joints driven by wires with variable length while operating The considered 5 degrees of freedom robotic arm has a particular structure of joint that makes possible inner actuation with wire-driven mechanism. We analyse solely the length change of wires as a consequence due inner winding and unwinding on joints for certain values of rotational angles. Variations in wires length entail joint angular displacements. We analyse positioning precision by taking into consideration equations from inverse kinematics of the elephant's trunk robotic arm. The angular displacements of joints are considered into computational method after partial derivation of positioning equations. We obtain variations of wires length at about tenths of micrometers. These variations employ angular displacements which are about minutes of sexagesimal degree and, thus, define positioning precision of elephant's trunk robotic arms. The analytical method is used for determining aftermath design structure of an elephant's trunk robotic arm with inner actuation through wires on positioning precision. Thus, designers could take suitable decisions on accuracy specifications limits of the robotic arm.

  10. Adaptive training algorithm for robot-assisted upper-arm rehabilitation, applicable to individualised and therapeutic human-robot interaction.

    Science.gov (United States)

    Chemuturi, Radhika; Amirabdollahian, Farshid; Dautenhahn, Kerstin

    2013-09-28

    Rehabilitation robotics is progressing towards developing robots that can be used as advanced tools to augment the role of a therapist. These robots are capable of not only offering more frequent and more accessible therapies but also providing new insights into treatment effectiveness based on their ability to measure interaction parameters. A requirement for having more advanced therapies is to identify how robots can 'adapt' to each individual's needs at different stages of recovery. Hence, our research focused on developing an adaptive interface for the GENTLE/A rehabilitation system. The interface was based on a lead-lag performance model utilising the interaction between the human and the robot. The goal of the present study was to test the adaptability of the GENTLE/A system to the performance of the user. Point-to-point movements were executed using the HapticMaster (HM) robotic arm, the main component of the GENTLE/A rehabilitation system. The points were displayed as balls on the screen and some of the points also had a real object, providing a test-bed for the human-robot interaction (HRI) experiment. The HM was operated in various modes to test the adaptability of the GENTLE/A system based on the leading/lagging performance of the user. Thirty-two healthy participants took part in the experiment comprising of a training phase followed by the actual-performance phase. The leading or lagging role of the participant could be used successfully to adjust the duration required by that participant to execute point-to-point movements, in various modes of robot operation and under various conditions. The adaptability of the GENTLE/A system was clearly evident from the durations recorded. The regression results showed that the participants required lower execution times with the help from a real object when compared to just a virtual object. The 'reaching away' movements were longer to execute when compared to the 'returning towards' movements irrespective of the

  11. A Non-linear Model for Predicting Tip Position of a Pliable Robot Arm Segment Using Bending Sensor Data

    Directory of Open Access Journals (Sweden)

    Elizabeth I. SKLAR

    2016-04-01

    Full Text Available Using pliable materials for the construction of robot bodies presents new and interesting challenges for the robotics community. Within the EU project entitled STIFFness controllable Flexible & Learnable manipulator for surgical Operations (STIFF-FLOP, a bendable, segmented robot arm has been developed. The exterior of the arm is composed of a soft material (silicone, encasing an internal structure that contains air-chamber actuators and a variety of sensors for monitoring applied force, position and shape of the arm as it bends. Due to the physical characteristics of the arm, a proper model of robot kinematics and dynamics is difficult to infer from the sensor data. Here we propose a non-linear approach to predicting the robot arm posture, by training a feed-forward neural network with a structured series of pressures values applied to the arm's actuators. The model is developed across a set of seven different experiments. Because the STIFF-FLOP arm is intended for use in surgical procedures, traditional methods for position estimation (based on visual information or electromagnetic tracking will not be possible to implement. Thus the ability to estimate pose based on data from a custom fiber-optic bending sensor and accompanying model is a valuable contribution. Results are presented which demonstrate the utility of our non-linear modelling approach across a range of data collection procedures.

  12. Crimped braided sleeves for soft, actuating arm in robotic abdominal surgery.

    Science.gov (United States)

    Elsayed, Yahya; Lekakou, Constantina; Ranzani, Tommaso; Cianchetti, Matteo; Morino, Mario; Arezzo, Alberto; Menciassi, Arianna; Geng, Tao; Saaj, Chakravarthini M

    2015-01-01

    This paper investigates different types of crimped, braided sleeve used for a soft arm for robotic abdominal surgery, with the sleeve required to contain balloon expansion in the pneumatically actuating arm while it follows the required bending, elongation and diameter reduction of the arm. Three types of crimped, braided sleeves from PET (BraidPET) or nylon (BraidGreyNylon and BraidNylon, with different monofilament diameters) were fabricated and tested including geometrical and microstructural characterisation of the crimp and braid, mechanical tests and medical scratching tests for organ damage of domestic pigs. BraidPET caused some organ damage, sliding under normal force of 2-5 N; this was attributed to the high roughness of the braid pattern, the higher friction coefficient of polyethylene terephthalate (PET) compared to nylon, and the high frequency of the crimp peaks for this sleeve. No organ damage was observed for the BraidNylon, attributed to both the lower roughness of the braid pattern and the low friction coefficient of nylon. BraidNylon also required the lowest tensile force during its elongation to similar maximum strain as that of BraidPET, translating to low power requirements. BraidNylon is recommended for the crimped sleeve of the arm designed for robotic abdominal surgery.

  13. A spatial registration method for navigation system combining O-arm with spinal surgery robot

    Science.gov (United States)

    Bai, H.; Song, G. L.; Zhao, Y. W.; Liu, X. Z.; Jiang, Y. X.

    2018-05-01

    The minimally invasive surgery in spinal surgery has become increasingly popular in recent years as it reduces the chances of complications during post-operation. However, the procedure of spinal surgery is complicated and the surgical vision of minimally invasive surgery is limited. In order to increase the quality of percutaneous pedicle screw placement, the O-arm that is a mobile intraoperative imaging system is used to assist surgery. The robot navigation system combined with O-arm is also increasing, with the extensive use of O-arm. One of the major problems in the surgical navigation system is to associate the patient space with the intra-operation image space. This study proposes a spatial registration method of spinal surgical robot navigation system, which uses the O-arm to scan a calibration phantom with metal calibration spheres. First, the metal artifacts were reduced in the CT slices and then the circles in the images based on the moments invariant could be identified. Further, the position of the calibration sphere in the image space was obtained. Moreover, the registration matrix is obtained based on the ICP algorithm. Finally, the position error is calculated to verify the feasibility and accuracy of the registration method.

  14. Compliant behaviour of redundant robot arm - experiments with null-space

    Directory of Open Access Journals (Sweden)

    Petrović Petar B.

    2015-01-01

    Full Text Available This paper presents theoretical and experimental aspects of Jacobian nullspace use in kinematically redundant robots for achieving kinetostatically consistent control of their compliant behavior. When the stiffness of the robot endpoint is dominantly influenced by the compliance of the robot joints, generalized stiffness matrix can be mapped into joint space using appropriate congruent transformation. Actuation stiffness matrix achieved by this transformation is generally nondiagonal. Off-diagonal elements of the actuation matrix can be generated by redundant actuation only (polyarticular actuators, but such kind of actuation is very difficult to realize practically in technical systems. The approach of solving this problem which is proposed in this paper is based on the use of kinematic redundancy and nullspace of the Jacobian matrix. Evaluation of the developed analytical model was done numerically by a minimal redundant robot with one redundant d.o.f. and experimentally by a 7 d.o.f. Yaskawa SIA 10F robot arm. [Projekat Ministarstva nauke Republike Srbije, br. TR35007

  15. A statically balanced and bi-stable compliant end effector combined with a laparoscopic 2DoF robotic arm

    NARCIS (Netherlands)

    Lassooij, J.; Tolou, N.; Tortora, G.; Caccavaro, S.; Menciassi, A.; Herder, J.L.

    2012-01-01

    This article presents the design of a newly developed 2DoF robotic arm with a novel statically balanced and bi-stable compliant grasper as the end effector for laparoscopic surgery application. The arm is based on internal motors actuating 2 rotational DoFs: pitch and roll. The positive stiffness of

  16. Robotically facilitated virtual rehabilitation of arm transport integrated with finger movement in persons with hemiparesis

    Directory of Open Access Journals (Sweden)

    Davidow Amy

    2011-05-01

    Full Text Available Abstract Background Recovery of upper extremity function is particularly recalcitrant to successful rehabilitation. Robotic-assisted arm training devices integrated with virtual targets or complex virtual reality gaming simulations are being developed to deal with this problem. Neural control mechanisms indicate that reaching and hand-object manipulation are interdependent, suggesting that training on tasks requiring coordinated effort of both the upper arm and hand may be a more effective method for improving recovery of real world function. However, most robotic therapies have focused on training the proximal, rather than distal effectors of the upper extremity. This paper describes the effects of robotically-assisted, integrated upper extremity training. Methods Twelve subjects post-stroke were trained for eight days on four upper extremity gaming simulations using adaptive robots during 2-3 hour sessions. Results The subjects demonstrated improved proximal stability, smoothness and efficiency of the movement path. This was in concert with improvement in the distal kinematic measures of finger individuation and improved speed. Importantly, these changes were accompanied by a robust 16-second decrease in overall time in the Wolf Motor Function Test and a 24-second decrease in the Jebsen Test of Hand Function. Conclusions Complex gaming simulations interfaced with adaptive robots requiring integrated control of shoulder, elbow, forearm, wrist and finger movements appear to have a substantial effect on improving hemiparetic hand function. We believe that the magnitude of the changes and the stability of the patient's function prior to training, along with maintenance of several aspects of the gains demonstrated at retention make a compelling argument for this approach to training.

  17. Robotically facilitated virtual rehabilitation of arm transport integrated with finger movement in persons with hemiparesis.

    Science.gov (United States)

    Merians, Alma S; Fluet, Gerard G; Qiu, Qinyin; Saleh, Soha; Lafond, Ian; Davidow, Amy; Adamovich, Sergei V

    2011-05-16

    Recovery of upper extremity function is particularly recalcitrant to successful rehabilitation. Robotic-assisted arm training devices integrated with virtual targets or complex virtual reality gaming simulations are being developed to deal with this problem. Neural control mechanisms indicate that reaching and hand-object manipulation are interdependent, suggesting that training on tasks requiring coordinated effort of both the upper arm and hand may be a more effective method for improving recovery of real world function. However, most robotic therapies have focused on training the proximal, rather than distal effectors of the upper extremity. This paper describes the effects of robotically-assisted, integrated upper extremity training. Twelve subjects post-stroke were trained for eight days on four upper extremity gaming simulations using adaptive robots during 2-3 hour sessions. The subjects demonstrated improved proximal stability, smoothness and efficiency of the movement path. This was in concert with improvement in the distal kinematic measures of finger individuation and improved speed. Importantly, these changes were accompanied by a robust 16-second decrease in overall time in the Wolf Motor Function Test and a 24-second decrease in the Jebsen Test of Hand Function. Complex gaming simulations interfaced with adaptive robots requiring integrated control of shoulder, elbow, forearm, wrist and finger movements appear to have a substantial effect on improving hemiparetic hand function. We believe that the magnitude of the changes and the stability of the patient's function prior to training, along with maintenance of several aspects of the gains demonstrated at retention make a compelling argument for this approach to training.

  18. Active Vision for Sociable Robots

    National Research Council Canada - National Science Library

    Breazeal, Cynthia; Edsinger, Aaron; Fitzpatrick, Paul; Scassellati, Brian

    2001-01-01

    .... In humanoid robotic systems, or in any animate vision system that interacts with people, social dynamics provide additional levels of constraint and provide additional opportunities for processing economy...

  19. Hybrid Taguchi DNA Swarm Intelligence for Optimal Inverse Kinematics Redundancy Resolution of Six-DOF Humanoid Robot Arms

    Directory of Open Access Journals (Sweden)

    Hsu-Chih Huang

    2014-01-01

    Full Text Available This paper presents a hybrid Taguchi deoxyribonucleic acid (DNA swarm intelligence for solving the inverse kinematics redundancy problem of six degree-of-freedom (DOF humanoid robot arms. The inverse kinematics problem of the multi-DOF humanoid robot arm is redundant and has no general closed-form solutions or analytical solutions. The optimal joint configurations are obtained by minimizing the predefined performance index in DNA algorithm for real-world humanoid robotics application. The Taguchi method is employed to determine the DNA parameters to search for the joint solutions of the six-DOF robot arms more efficiently. This approach circumvents the disadvantage of time-consuming tuning procedure in conventional DNA computing. Simulation results are conducted to illustrate the effectiveness and merit of the proposed methods. This Taguchi-based DNA (TDNA solver outperforms the conventional solvers, such as geometric solver, Jacobian-based solver, genetic algorithm (GA solver and ant, colony optimization (ACO solver.

  20. Early Stroke Rehabilitation of the Upper Limb Assisted with an Electromyography-Driven Neuromuscular Electrical Stimulation-Robotic Arm

    Directory of Open Access Journals (Sweden)

    Qiuyang Qian

    2017-09-01

    Full Text Available BackgroundEffective poststroke motor rehabilitation depends on repeated limb practice with voluntary efforts. An electromyography (EMG-driven neuromuscular electrical stimulation (NMES-robot arm was designed for the multi-joint physical training on the elbow, the wrist, and the fingers.ObjectivesTo investigate the training effects of the device-assisted approach on subacute stroke patients and to compare the effects with those achieved by the traditional physical treatments.MethodThis study was a pilot randomized controlled trial with a 3-month follow-up. Subacute stroke participants were randomly assigned into two groups, and then received 20-session upper limb training with the EMG-driven NMES-robotic arm (NMES-robot group, n = 14 or the time-matched traditional therapy (the control, n = 10. For the evaluation of the training effects, clinical assessments including Fugl-Meyer Assessment (FMA, Modified Ashworth Score (MAS, Action Research Arm Test (ARAT, and Function Independence Measurement (FIM were conducted before, after the rehabilitation training, and 3 months later. Session-by-session EMG parameters in the NMES-robot group, including normalized co-contraction Indexes (CI and EMG activation level of target muscles, were used to monitor the progress in muscular coordination patterns.ResultsSignificant improvements were obtained in FMA (full score and shoulder/elbow, ARAT, and FIM [P < 0.001, effect sizes (EFs > 0.279] for both groups. Significant improvement in FMA wrist/hand was only observed in the NMES-robot group (P < 0.001, EFs = 0.435 after the treatments. Significant reduction in MAS wrist was observed in the NMES-robot group after the training (P < 0.05, EFs = 0.145 and the effects were maintained for 3 months. MAS scores in the control group were elevated following training (P < 0.05, EFs > 0.24, and remained at an elevated level when assessed 3 months later. The EMG parameters

  1. Dynamic parameter identification of robot arms with servo-controlled electrical motors

    Science.gov (United States)

    Jiang, Zhao-Hui; Senda, Hiroshi

    2005-12-01

    This paper addresses the issue of dynamic parameter identification of the robot manipulator with servo-controlled electrical motors. An assumption is made that all kinematical parameters, such as link lengths, are known, and only dynamic parameters containing mass, moment of inertia, and their functions need to be identified. First, we derive dynamics of the robot arm with a linear form of the unknown dynamic parameters by taking dynamic characteristics of the motor and servo unit into consideration. Then, we implement the parameter identification approach to identify the unknown parameters with respect to individual link separately. A pseudo-inverse matrix is used for formulation of the parameter identification. The optimal solution is guaranteed in a sense of least-squares of the mean errors. A Direct Drive (DD) SCARA type industrial robot arm AdeptOne is used as an application example of the parameter identification. Simulations and experiments for both open loop and close loop controls are carried out. Comparison of the results confirms the correctness and usefulness of the parameter identification and the derived dynamic model.

  2. An automated robot arm system for small animal tissue biopsy under dual-image modality

    International Nuclear Information System (INIS)

    Huang, Y.H.; Wu, T.H.; Lin, M.H.; Yang, C.C.; Guo, W.Y.; Wang, Z.J.; Chen, C.L.; Lee, J.S.

    2006-01-01

    The ability to non-invasively monitor cell biology in vivo is one of the most important goals of molecular imaging. Imaging procedures could be inter-subject performed repeatedly at different investigating stages; thereby need not sacrifice small animals during the entire study period. Thus, the ultimate goal of this study was to design a stereotactic image-guided system for small animals and integrated it with an automatic robot arm for in vivo tissue biopsy analysis. The system was composed of three main parts, including one small animal stereotactic frame, one imaging-fusion software and an automatic robot arm system. The system has been thoroughly evaluated with three components; the robot position accuracy was 0.05±0.02 mm, the image registration accuracy was 0.37±0.18 mm and the system integration was satisfactorily within 1.20±0.39 mm of error. From these results, the system demonstrated sufficient accuracy to guide the micro-injector from the planned delivery routes into practice. The entire system accuracy was limited by the image fusion and orientation procedures, due to its nature of the blurred PET imaging obtained from the small objects. The primary improvement is to acquire as higher resolution as possible the fused imaging for localizing the targets in the future

  3. Using Human Gestures and Generic Skills to Instruct a Mobile Robot Arm in a Feeder Filling Scenario

    DEFF Research Database (Denmark)

    Pedersen, Mikkel Rath; Høilund, Carsten; Krüger, Volker

    2012-01-01

    Mobile robots that have the ability to cooperate with humans are able to provide new possibilities to manufac- turing industries. In this paper, we discuss our mobile robot arm that a) can provide assistance at different locations in a factory and b) that can be programmed using complex human...... actions such as pointing in Take this object. In this paper, we discuss the use of the mobile robot for a feeding scenario where a human operator specifies the parts and the feeders through pointing gestures. The system is partially built using generic robotic skills. Through extensive experiments, we...

  4. Development of a Multi-Arm Mobile Robot for Nuclear Decommissioning Tasks

    Directory of Open Access Journals (Sweden)

    Mohamed J. Bakari

    2008-11-01

    Full Text Available This paper concerns the design of a two-arm mobile delivery platform for application within nuclear decommissioning tasks. The adoption of the human arm as a model of manoeuvrability, scale and dexterity is the starting point for operation of two seven-function arms within the context of nuclear decommissioning tasks, the selection of hardware and its integration, and the development of suitable control methods. The forward and inverse kinematics for the manipulators are derived and the proposed software architecture identified to control the movements of the arm joints and the performance of selected decommissioning tasks. We discuss the adoption of a BROKK demolition machine as a mobile platform and the integration with its hydraulic system to operate the two seven-function manipulators separately. The paper examines the modelling and development of a real-time control method using Proportional-Integral-Derivative (PID and Proportional-Integral-Plus (PIP control algorithms in the host computer with National Instruments functions and tools to control the manipulators and obtain feedback through wireless communication. Finally we consider the application of a third party device, such as a personal mobile phone, and its interface with LabVIEW software in order to operate the robot arms remotely.

  5. Estimation of Human Arm Joints Using Two Wireless Sensors in Robotic Rehabilitation Tasks

    Directory of Open Access Journals (Sweden)

    Arturo Bertomeu-Motos

    2015-12-01

    Full Text Available This paper presents a novel kinematic reconstruction of the human arm chain with five degrees of freedom and the estimation of the shoulder location during rehabilitation therapy assisted by end-effector robotic devices. This algorithm is based on the pseudoinverse of the Jacobian through the acceleration of the upper arm, measured using an accelerometer, and the orientation of the shoulder, estimated with a magnetic angular rate and gravity (MARG device. The results show a high accuracy in terms of arm joints and shoulder movement with respect to the real arm measured through an optoelectronic system. Furthermore, the range of motion (ROM of 50 healthy subjects is studied from two different trials, one trying to avoid shoulder movements and the second one forcing them. Moreover, the shoulder movement in the second trial is also estimated accurately. Besides the fact that the posture of the patient can be corrected during the exercise, the therapist could use the presented algorithm as an objective assessment tool. In conclusion, the joints’ estimation enables a better adjustment of the therapy, taking into account the needs of the patient, and consequently, the arm motion improves faster.

  6. A Remote Controlled Robotic Arm That Reads Barcodes and Handles Products

    Directory of Open Access Journals (Sweden)

    Zhi-Ying Chen

    2018-03-01

    Full Text Available In this study, a 6-axis robotic arm, which was controlled by an embedded Raspberry Pi with onboard WiFi, was developed and fabricated. A mobile application (APP, designed for the purpose, was used to operate and monitor a robotic arm by means of a WiFi connection. A computer vision was used to read common one-dimensional barcode (EAN code for the handling and identification of products such as milk tea drinks, sodas and biscuits. The gripper on the end of the arm could sense the clamping force and allowed real-time control of the amount of force used to hold and handle the products. The packages were all made of different material and this control allowed them to be handled without danger of damage or deformation. The maximum handling torque used was ~1.08 Nm and the mechanical design allowed the force of the gripper to be uniformly applied to the sensor to ensure accurate measurement of the force.

  7. Grasp planning for a reconfigurable parallel robot with an underactuated arm structure

    Directory of Open Access Journals (Sweden)

    M. Riedel

    2010-12-01

    Full Text Available In this paper, a novel approach of grasp planning is applied to find out the appropriate grasp points for a reconfigurable parallel robot called PARAGRIP (Parallel Gripping. This new handling system is able to manipulate objects in the six-dimensional Cartesian space by several robotic arms using only six actuated joints. After grasping, the contact elements at the end of the underactuated arm mechanisms are connected to the object which forms a closed loop mechanism similar to the architecture of parallel manipulators. As the mounting and grasp points of the arms can easily be changed, the manipulator can be reconfigured to match the user's preferences and needs. This paper raises the question, how and where these grasp points are to be placed on the object to perform well for a certain manipulation task.

    This paper was presented at the IFToMM/ASME International Workshop on Underactuated Grasping (UG2010, 19 August 2010, Montréal, Canada.

  8. Trajectory Planning with Pose Feedback for a Dual-Arm Space Robot

    Directory of Open Access Journals (Sweden)

    Yicheng Liu

    2016-01-01

    Full Text Available In order to obtain high precision path tracking for a dual-arm space robot, a trajectory planning method with pose feedback is proposed to be introduced into the design process in this paper. Firstly, pose error kinematic models are derived from the related kinematics and desired pose command for the end-effector and the base, respectively. On this basis, trajectory planning with pose feedback is proposed from a control perspective. Theoretical analyses show that the proposed trajectory planning algorithm can guarantee that pose error converges to zero exponentially for both the end-effector and the base when the robot is out of singular configuration. Compared with the existing algorithms, the proposed algorithm can lead to higher precision path tracking for the end-effector. Furthermore, the algorithm renders the system good anti-interference property for the base. Simulation results demonstrate the effectiveness of the proposed trajectory planning algorithm.

  9. GENERAL CONSIDERATIONS OF THE EMPLOYMENT OF ROBOTS IN ARMED CONFLICTS IN THE XXI CENTURY

    Directory of Open Access Journals (Sweden)

    LUIS PÉREZ GIL

    2017-09-01

    Full Text Available This article studies the new weapon systems that can transform the notion itself of “armed conflict” in the classic sense of the term. The author deeply analyzes the differences between concepts such as robot, droid, android, UAS and UCAS, the new military hardware, and how will be the combat aircrafts of the future with systems of artificial intelligence, the field robotics, as well as the interaction between men and machines in the future combat and, finally, the revolution that the employment of this type of weapons cause in the traditional concepts of Humanitarian Law and self-defense right. The author concludes with a few reflections on the role that the newest technologies have to play necessarily in the conventional and unconventional warfare and the influence that its use will produce when these weapons will be considered “normal” in the whole world system.

  10. Four-arm single docking full robotic surgery for low rectal cancer: technique standardization

    Directory of Open Access Journals (Sweden)

    José Reinan Ramos

    Full Text Available The authors present the four-arm single docking full robotic surgery to treat low rectal cancer. The eight main operative steps are: 1- patient positioning; 2- trocars set-up and robot docking; 3- sigmoid colon, left colon and splenic flexure mobilization (lateral-to-medial approach; 4-Inferior mesenteric artery and vein ligation (medial-to-lateral approach; 5- total mesorectum excision and preservation of hypogastric and pelvic autonomic nerves (sacral dissection, lateral dissection, pelvic dissection; 6- division of the rectum using an endo roticulator stapler for the laparoscopic performance of a double-stapled coloanal anastomosis (type I tumor; 7- intersphincteric resection, extraction of the specimen through the anus and lateral-to-end hand sewn coloanal anastomosis (type II tumor; 8- cylindric abdominoperineal resection, with transabdominal section of the levator muscles (type IV tumor. The techniques employed were safe and have presented low rates of complication and no mortality.

  11. Thoughts turned into high-level commands: Proof-of-concept study of a vision-guided robot arm driven by functional MRI (fMRI) signals.

    Science.gov (United States)

    Minati, Ludovico; Nigri, Anna; Rosazza, Cristina; Bruzzone, Maria Grazia

    2012-06-01

    Previous studies have demonstrated the possibility of using functional MRI to control a robot arm through a brain-machine interface by directly coupling haemodynamic activity in the sensory-motor cortex to the position of two axes. Here, we extend this work by implementing interaction at a more abstract level, whereby imagined actions deliver structured commands to a robot arm guided by a machine vision system. Rather than extracting signals from a small number of pre-selected regions, the proposed system adaptively determines at individual level how to map representative brain areas to the input nodes of a classifier network. In this initial study, a median action recognition accuracy of 90% was attained on five volunteers performing a game consisting of collecting randomly positioned coloured pawns and placing them into cups. The "pawn" and "cup" instructions were imparted through four mental imaginery tasks, linked to robot arm actions by a state machine. With the current implementation in MatLab language the median action recognition time was 24.3s and the robot execution time was 17.7s. We demonstrate the notion of combining haemodynamic brain-machine interfacing with computer vision to implement interaction at the level of high-level commands rather than individual movements, which may find application in future fMRI approaches relevant to brain-lesioned patients, and provide source code supporting further work on larger command sets and real-time processing. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  12. Intelligent control of robotic arm/hand systems for the NASA EVA retriever using neural networks

    Science.gov (United States)

    Mclauchlan, Robert A.

    1989-01-01

    Adaptive/general learning algorithms using varying neural network models are considered for the intelligent control of robotic arm plus dextrous hand/manipulator systems. Results are summarized and discussed for the use of the Barto/Sutton/Anderson neuronlike, unsupervised learning controller as applied to the stabilization of an inverted pendulum on a cart system. Recommendations are made for the application of the controller and a kinematic analysis for trajectory planning to simple object retrieval (chase/approach and capture/grasp) scenarios in two dimensions.

  13. Visual Attention Allocation Between Robotic Arm and Environmental Process Control: Validating the STOM Task Switching Model

    Science.gov (United States)

    Wickens, Christopher; Vieanne, Alex; Clegg, Benjamin; Sebok, Angelia; Janes, Jessica

    2015-01-01

    Fifty six participants time shared a spacecraft environmental control system task with a realistic space robotic arm control task in either a manual or highly automated version. The former could suffer minor failures, whose diagnosis and repair were supported by a decision aid. At the end of the experiment this decision aid unexpectedly failed. We measured visual attention allocation and switching between the two tasks, in each of the eight conditions formed by manual-automated arm X expected-unexpected failure X monitoring- failure management. We also used our multi-attribute task switching model, based on task attributes of priority interest, difficulty and salience that were self-rated by participants, to predict allocation. An un-weighted model based on attributes of difficulty, interest and salience accounted for 96 percent of the task allocation variance across the 8 different conditions. Task difficulty served as an attractor, with more difficult tasks increasing the tendency to stay on task.

  14. Endoscopic endonasal transsphenoidal surgery using the iArmS operation support robot: initial experience in 43 patients.

    Science.gov (United States)

    Ogiwara, Toshihiro; Goto, Tetsuya; Nagm, Alhusain; Hongo, Kazuhiro

    2017-05-01

    Objective The intelligent arm-support system, iArmS, which follows the surgeon's arm and automatically fixes it at an adequate position, was developed as an operation support robot. iArmS was designed to support the surgeon's forearm to prevent hand trembling and to alleviate fatigue during surgery with a microscope. In this study, the authors report on application of this robotic device to endoscopic endonasal transsphenoidal surgery (ETSS) and evaluate their initial experiences. Methods The study population consisted of 43 patients: 29 with pituitary adenoma, 3 with meningioma, 3 with Rathke's cleft cyst, 2 with craniopharyngioma, 2 with chordoma, and 4 with other conditions. All patients underwent surgery via the endonasal transsphenoidal approach using a rigid endoscope. During the nasal and sphenoid phases, iArmS was used to support the surgeon's nondominant arm, which held the endoscope. The details of the iArmS and clinical results were collected. Results iArmS followed the surgeon's arm movement automatically. It reduced the surgeon's fatigue and stabilized the surgeon's hand during ETSS. Shaking of the video image decreased due to the steadying of the surgeon's scope-holding hand with iArmS. There were no complications related to use of the device. Conclusions The intelligent armrest, iArmS, seems to be safe and effective during ETSS. iArmS is helpful for improving the precision and safety not only for microscopic neurosurgery, but also for ETSS. Ongoing advances in robotics ensure the continued evolution of neurosurgery.

  15. Position Based Visual Servoing control of a Wheelchair Mounter Robotic Arm using Parallel Tracking and Mapping of task objects

    Directory of Open Access Journals (Sweden)

    Alessandro Palla

    2017-05-01

    Full Text Available In the last few years power wheelchairs have been becoming the only device able to provide autonomy and independence to people with motor skill impairments. In particular, many power wheelchairs feature robotic arms for gesture emulation, like the interaction with objects. However, complex robotic arms often require a joystic to be controlled; this feature make the arm hard to be controlled by impaired users. Paradoxically, if the user were able to proficiently control such devices, he would not need them. For that reason, this paper presents a highly autonomous robotic arm, designed in order to minimize the effort necessary for the control of the arm. In order to do that, the arm feature an easy to use human - machine interface and is controlled by Computer Vison algorithm, implementing a Position Based Visual Servoing (PBVS control. It was realized by extracting features by the camera and fusing them with the distance from the target, obtained by a proximity sensor. The Parallel Tracking and Mapping (PTAM algorithm was used to find the 3D position of the task object in the camera reference system. The visual servoing algorithm was implemented in an embedded platform, in real time. Each part of the control loop was developed in Robotic Operative System (ROS Environment, which allows to implement the previous algorithms as different nodes. Theoretical analysis, simulations and in system measurements proved the effectiveness of the proposed solution.

  16. Robot hands and extravehicular activity

    Science.gov (United States)

    Marcus, Beth

    1987-01-01

    Extravehicular activity (EVA) is crucial to the success of both current and future space operations. As space operations have evolved in complexity so has the demand placed on the EVA crewman. In addition, some NASA requirements for human capabilities at remote or hazardous sites were identified. One of the keys to performing useful EVA tasks is the ability to manipulate objects accurately, quickly and without early or excessive fatigue. The current suit employs a glove which enables the crewman to perform grasping tasks, use tools, turn switches, and perform other tasks for short periods of time. However, the glove's bulk and resistance to motion ultimately causes fatigue. Due to this limitation it may not be possible to meet the productivity requirements that will be placed on the EVA crewman of the future with the current or developmental Extravehicular Mobility Unit (EMU) hardware. In addition, this hardware will not meet the requirements for remote or hazardous operations. In an effort to develop ways for improving crew productivity, a contract was awarded to develop a prototype anthromorphic robotic hand (ARH) for use with an extravehicular space suit. The first step in this program was to perform a a design study which investigated the basic technology required for the development of an ARH to enhance crew performance and productivity. The design study phase of the contract and some additional development work is summarized.

  17. Analysis of the features of untrained human movements based on the multichannel EEG for controlling anthropomorphic robotic arm

    Science.gov (United States)

    Maksimenko, Vladimir; Runnova, Anastasia; Pchelintseva, Svetlana; Efremova, Tatiana; Zhuravlev, Maksim; Pisarchik, Alexander

    2018-04-01

    We have considered time-frequency and spatio-temporal structure of electrical brain activity, associated with real and imaginary movements based on the multichannel EEG recordings. We have found that along with wellknown effects of event-related desynchronization (ERD) in α/μ - rhythms and β - rhythm, these types of activity are accompanied by the either ERS (for real movement) or ERD (for imaginary movement) in low-frequency δ - band, located mostly in frontal lobe. This may be caused by the associated processes of decision making, which take place when subject is deciding either perform the movement or imagine it. Obtained features have been found in untrained subject which it its turn gives the possibility to use our results in the development of brain-computer interfaces for controlling anthropomorphic robotic arm.

  18. Novel Adaptive Forward Neural MIMO NARX Model for the Identification of Industrial 3-DOF Robot Arm Kinematics

    Directory of Open Access Journals (Sweden)

    Ho Pham Huy Anh

    2012-10-01

    Full Text Available In this paper, a novel forward adaptive neural MIMO NARX model is used for modelling and identifying the forward kinematics of an industrial 3-DOF robot arm system. The nonlinear features of the forward kinematics of the industrial robot arm drive are thoroughly modelled based on the forward adaptive neural NARX model-based identification process using experimental input-output training data. This paper proposes a novel use of a back propagation (BP algorithm to generate the forward neural MIMO NARX (FNMN model for the forward kinematics of the industrial 3-DOF robot arm. The results show that the proposed adaptive neural NARX model trained by a Back Propagation learning algorithm yields outstanding performance and perfect accuracy.

  19. Robotics

    International Nuclear Information System (INIS)

    Scheide, A.W.

    1983-01-01

    This article reviews some of the technical areas and history associated with robotics, provides information relative to the formation of a Robotics Industry Committee within the Industry Applications Society (IAS), and describes how all activities relating to robotics will be coordinated within the IEEE. Industrial robots are being used for material handling, processes such as coating and arc welding, and some mechanical and electronics assembly. An industrial robot is defined as a programmable, multifunctional manipulator designed to move material, parts, tools, or specialized devices through variable programmed motions for a variety of tasks. The initial focus of the Robotics Industry Committee will be on the application of robotics systems to the various industries that are represented within the IAS

  20. EVALUATING CONTINUOUS-TIME SLAM USING A PREDEFINED TRAJECTORY PROVIDED BY A ROBOTIC ARM

    Directory of Open Access Journals (Sweden)

    B. Koch

    2017-09-01

    Full Text Available Recently published approaches to SLAM algorithms process laser sensor measurements and output a map as a point cloud of the environment. Often the actual precision of the map remains unclear, since SLAMalgorithms apply local improvements to the resulting map. Unfortunately, it is not trivial to compare the performance of SLAMalgorithms objectively, especially without an accurate ground truth. This paper presents a novel benchmarking technique that allows to compare a precise map generated with an accurate ground truth trajectory to a map with a manipulated trajectory which was distorted by different forms of noise. The accurate ground truth is acquired by mounting a laser scanner on an industrial robotic arm. The robotic arm is moved on a predefined path while the position and orientation of the end-effector tool are monitored. During this process the 2D profile measurements of the laser scanner are recorded in six degrees of freedom and afterwards used to generate a precise point cloud of the test environment. For benchmarking, an offline continuous-time SLAM algorithm is subsequently applied to remove the inserted distortions. Finally, it is shown that the manipulated point cloud is reversible to its previous state and is slightly improved compared to the original version, since small errors that came into account by imprecise assumptions, sensor noise and calibration errors are removed as well.

  1. Two-dimensional myoelectric control of a robotic arm for upper limb amputees

    International Nuclear Information System (INIS)

    Lopez Celani, Natalia M; Soria, Carlos M; Orosco, Eugenio C; Di Sciascio, Fernando A; Valentinuzzi, Max E

    2007-01-01

    Rehabilitation engineering and medicine have become integral and significant parts of health care services, particularly and unfortunately in the last three or four decades, because of wars, terrorism and large number of car accidents. Amputees show a high rate of rejection to wear prosthetic devices, often because of lack of an adequate period of adaptation. A robotic arm may appear as a good preliminary stage. To test the hypothesis, myoelectric signals from two upper limb amputees and from four normal volunteers were fed, via adequate electronic conditioning and using MATLAB, to an industrial robotic arm. Proportional strength control was used for two degrees of freedom (x-y plane) by means of eight signal features of control (four traditional statistics plus energy, integral of the absolute value, Willison's amplitude, waveform length and envelope) for comparison purposes, and selecting the best of them as final reference. Patients easily accepted the system and learned in short time how to operate it. Results were encouraging so that valuable training, before prosthesis is implanted, appears as good feedback; besides, these patients can be hired as specialized operators in semi-automatized industry

  2. Two-dimensional myoelectric control of a robotic arm for upper limb amputees

    Science.gov (United States)

    López Celani, Natalia M.; Soria, Carlos M.; Orosco, Eugenio C.; di Sciascio, Fernando A.; Valentinuzzi, Max E.

    2007-11-01

    Rehabilitation engineering and medicine have become integral and significant parts of health care services, particularly and unfortunately in the last three or four decades, because of wars, terrorism and large number of car accidents. Amputees show a high rate of rejection to wear prosthetic devices, often because of lack of an adequate period of adaptation. A robotic arm may appear as a good preliminary stage. To test the hypothesis, myoelectric signals from two upper limb amputees and from four normal volunteers were fed, via adequate electronic conditioning and using MATLAB, to an industrial robotic arm. Proportional strength control was used for two degrees of freedom (x-y plane) by means of eight signal features of control (four traditional statistics plus energy, integral of the absolute value, Willison's amplitude, waveform length and envelope) for comparison purposes, and selecting the best of them as final reference. Patients easily accepted the system and learned in short time how to operate it. Results were encouraging so that valuable training, before prosthesis is implanted, appears as good feedback; besides, these patients can be hired as specialized operators in semi-automatized industry.

  3. Evaluating Continuous-Time Slam Using a Predefined Trajectory Provided by a Robotic Arm

    Science.gov (United States)

    Koch, B.; Leblebici, R.; Martell, A.; Jörissen, S.; Schilling, K.; Nüchter, A.

    2017-09-01

    Recently published approaches to SLAM algorithms process laser sensor measurements and output a map as a point cloud of the environment. Often the actual precision of the map remains unclear, since SLAMalgorithms apply local improvements to the resulting map. Unfortunately, it is not trivial to compare the performance of SLAMalgorithms objectively, especially without an accurate ground truth. This paper presents a novel benchmarking technique that allows to compare a precise map generated with an accurate ground truth trajectory to a map with a manipulated trajectory which was distorted by different forms of noise. The accurate ground truth is acquired by mounting a laser scanner on an industrial robotic arm. The robotic arm is moved on a predefined path while the position and orientation of the end-effector tool are monitored. During this process the 2D profile measurements of the laser scanner are recorded in six degrees of freedom and afterwards used to generate a precise point cloud of the test environment. For benchmarking, an offline continuous-time SLAM algorithm is subsequently applied to remove the inserted distortions. Finally, it is shown that the manipulated point cloud is reversible to its previous state and is slightly improved compared to the original version, since small errors that came into account by imprecise assumptions, sensor noise and calibration errors are removed as well.

  4. A comparison of robotic arm versus gantry linear accelerator stereotactic body radiation therapy for prostate cancer.

    Science.gov (United States)

    Avkshtol, Vladimir; Dong, Yanqun; Hayes, Shelly B; Hallman, Mark A; Price, Robert A; Sobczak, Mark L; Horwitz, Eric M; Zaorsky, Nicholas G

    2016-01-01

    Prostate cancer is the most prevalent cancer diagnosed in men in the United States besides skin cancer. Stereotactic body radiation therapy (SBRT; 6-15 Gy per fraction, up to 45 minutes per fraction, delivered in five fractions or less, over the course of approximately 2 weeks) is emerging as a popular treatment option for prostate cancer. The American Society for Radiation Oncology now recognizes SBRT for select low- and intermediate-risk prostate cancer patients. SBRT grew from the notion that high doses of radiation typical of brachytherapy could be delivered noninvasively using modern external-beam radiation therapy planning and delivery methods. SBRT is most commonly delivered using either a traditional gantry-mounted linear accelerator or a robotic arm-mounted linear accelerator. In this systematic review article, we compare and contrast the current clinical evidence supporting a gantry vs robotic arm SBRT for prostate cancer. The data for SBRT show encouraging and comparable results in terms of freedom from biochemical failure (>90% for low and intermediate risk at 5-7 years) and acute and late toxicity (6 MV). Finally, SBRT (particularly on a gantry) may also be more cost-effective than conventionally fractionated external-beam radiation therapy. Randomized controlled trials of SBRT using both technologies are underway.

  5. Performance and Usability of Various Robotic Arm Control Modes from Human Force Signals

    Directory of Open Access Journals (Sweden)

    Sébastien Mick

    2017-10-01

    Full Text Available Elaborating an efficient and usable mapping between input commands and output movements is still a key challenge for the design of robotic arm prostheses. In order to address this issue, we present and compare three different control modes, by assessing them in terms of performance as well as general usability. Using an isometric force transducer as the command device, these modes convert the force input signal into either a position or a velocity vector, whose magnitude is linearly or quadratically related to force input magnitude. With the robotic arm from the open source 3D-printed Poppy Humanoid platform simulating a mobile prosthesis, an experiment was carried out with eighteen able-bodied subjects performing a 3-D target-reaching task using each of the three modes. The subjects were given questionnaires to evaluate the quality of their experience with each mode, providing an assessment of their global usability in the context of the task. According to performance metrics and questionnaire results, velocity control modes were found to perform better than position control mode in terms of accuracy and quality of control as well as user satisfaction and comfort. Subjects also seemed to favor quadratic velocity control over linear (proportional velocity control, even if these two modes did not clearly distinguish from one another when it comes to performance and usability assessment. These results highlight the need to take into account user experience as one of the key criteria for the design of control modes intended to operate limb prostheses.

  6. On nonlinear dynamics and control of a robotic arm with chaos

    Directory of Open Access Journals (Sweden)

    Felix J. L. P.

    2014-01-01

    Full Text Available In this paper a robotic arm is modelled by a double pendulum excited in its base by a DC motor of limited power via crank mechanism and elastic connector. In the mathematical model, a chaotic motion was identified, for a wide range of parameters. Controlling of the chaotic behaviour of the system, were implemented using, two control techniques, the nonlinear saturation control (NSC and the optimal linear feedback control (OLFC. The actuator and sensor of the device are allowed in the pivot and joints of the double pendulum. The nonlinear saturation control (NSC is based in the order second differential equations and its action in the pivot/joint of the robotic arm is through of quadratic nonlinearities feedback signals. The optimal linear feedback control (OLFC involves the application of two control signals, a nonlinear feedforward control to maintain the controlled system to a desired periodic orbit, and control a feedback control to bring the trajectory of the system to the desired orbit. Simulation results, including of uncertainties show the feasibility of the both methods, for chaos control of the considered system.

  7. Computer vision system R&D for EAST Articulated Maintenance Arm robot

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Linglong, E-mail: linglonglin@ipp.ac.cn; Song, Yuntao, E-mail: songyt@ipp.ac.cn; Yang, Yang, E-mail: yangy@ipp.ac.cn; Feng, Hansheng, E-mail: hsfeng@ipp.ac.cn; Cheng, Yong, E-mail: chengyong@ipp.ac.cn; Pan, Hongtao, E-mail: panht@ipp.ac.cn

    2015-11-15

    Highlights: • We discussed the image preprocessing, object detection and pose estimation algorithms under poor light condition of inner vessel of EAST tokamak. • The main pipeline, including contours detection, contours filter, MER extracted, object location and pose estimation, was carried out in detail. • The technical issues encountered during the research were discussed. - Abstract: Experimental Advanced Superconducting Tokamak (EAST) is the first full superconducting tokamak device which was constructed at Institute of Plasma Physics Chinese Academy of Sciences (ASIPP). The EAST Articulated Maintenance Arm (EAMA) robot provides the means of the in-vessel maintenance such as inspection and picking up the fragments of first wall. This paper presents a method to identify and locate the fragments semi-automatically by using the computer vision. The use of computer vision in identification and location faces some difficult challenges such as shadows, poor contrast, low illumination level, less texture and so on. The method developed in this paper enables credible identification of objects with shadows through invariant image and edge detection. The proposed algorithms are validated through our ASIPP robotics and computer vision platform (ARVP). The results show that the method can provide a 3D pose with reference to robot base so that objects with different shapes and size can be picked up successfully.

  8. Thermal Tracking in Mobile Robots for Leak Inspection Activities

    Directory of Open Access Journals (Sweden)

    Iñaki Maurtua

    2013-10-01

    Full Text Available Maintenance tasks are crucial for all kind of industries, especially in extensive industrial plants, like solar thermal power plants. The incorporation of robots is a key issue for automating inspection activities, as it will allow a constant and regular control over the whole plant. This paper presents an autonomous robotic system to perform pipeline inspection for early detection and prevention of leakages in thermal power plants, based on the work developed within the MAINBOT (http://www.mainbot.eu European project. Based on the information provided by a thermographic camera, the system is able to detect leakages in the collectors and pipelines. Beside the leakage detection algorithms, the system includes a particle filter-based tracking algorithm to keep the target in the field of view of the camera and to avoid the irregularities of the terrain while the robot patrols the plant. The information provided by the particle filter is further used to command a robot arm, which handles the camera and ensures that the target is always within the image. The obtained results show the suitability of the proposed approach, adding a tracking algorithm to improve the performance of the leakage detection system.

  9. Thermal tracking in mobile robots for leak inspection activities.

    Science.gov (United States)

    Ibarguren, Aitor; Molina, Jorge; Susperregi, Loreto; Maurtua, Iñaki

    2013-10-09

    Maintenance tasks are crucial for all kind of industries, especially in extensive industrial plants, like solar thermal power plants. The incorporation of robots is a key issue for automating inspection activities, as it will allow a constant and regular control over the whole plant. This paper presents an autonomous robotic system to perform pipeline inspection for early detection and prevention of leakages in thermal power plants, based on the work developed within the MAINBOT (http://www.mainbot.eu) European project. Based on the information provided by a thermographic camera, the system is able to detect leakages in the collectors and pipelines. Beside the leakage detection algorithms, the system includes a particle filter-based tracking algorithm to keep the target in the field of view of the camera and to avoid the irregularities of the terrain while the robot patrols the plant. The information provided by the particle filter is further used to command a robot arm, which handles the camera and ensures that the target is always within the image. The obtained results show the suitability of the proposed approach, adding a tracking algorithm to improve the performance of the leakage detection system.

  10. A robotic C-arm cone beam CT system for image-guided proton therapy: design and performance.

    Science.gov (United States)

    Hua, Chiaho; Yao, Weiguang; Kidani, Takao; Tomida, Kazuo; Ozawa, Saori; Nishimura, Takenori; Fujisawa, Tatsuya; Shinagawa, Ryousuke; Merchant, Thomas E

    2017-11-01

    A ceiling-mounted robotic C-arm cone beam CT (CBCT) system was developed for use with a 190° proton gantry system and a 6-degree-of-freedom robotic patient positioner. We report on the mechanical design, system accuracy, image quality, image guidance accuracy, imaging dose, workflow, safety and collision-avoidance. The robotic CBCT system couples a rotating C-ring to the C-arm concentrically with a kV X-ray tube and a flat-panel imager mounted to the C-ring. CBCT images are acquired with flex correction and maximally 360° rotation for a 53 cm field of view. The system was designed for clinical use with three imaging locations. Anthropomorphic phantoms were imaged to evaluate the image guidance accuracy. The position accuracy and repeatability of the robotic C-arm was high (robotic CBCT system provides high-accuracy volumetric image guidance for proton therapy. Advances in knowledge: Ceiling-mounted robotic CBCT provides a viable option than CT on-rails for partial gantry and fixed-beam proton systems with the added advantage of acquiring images at the treatment isocentre.

  11. Exploring Ackermann and LQR stability control of stochastic state-space model of hexacopter equipped with robotic arm

    Science.gov (United States)

    Ibrahim, I. N.; Akkad, M. A. Al; Abramov, I. V.

    2018-05-01

    This paper discusses the control of Unmanned Aerial Vehicles (UAVs) for active interaction and manipulation of objects. The manipulator motion with an unknown payload was analysed concerning force and moment disturbances, which influence the mass distribution, and the centre of gravity (CG). Therefore, a general dynamics mathematical model of a hexacopter was formulated where a stochastic state-space model was extracted in order to build anti-disturbance controllers. Based on the compound pendulum method, the disturbances model that simulates the robotic arm with a payload was inserted into the stochastic model. This study investigates two types of controllers in order to study the stability of a hexacopter. A controller based on Ackermann’s method and the other - on the linear quadratic regulator (LQR) approach - were presented. The latter constitutes a challenge for UAV control performance especially with the presence of uncertainties and disturbances.

  12. Effects of intensive arm training with the rehabilitation robot ARMin II in chronic stroke patients: four single-cases

    Directory of Open Access Journals (Sweden)

    Nef Tobias

    2009-12-01

    Full Text Available Abstract Background Robot-assisted therapy offers a promising approach to neurorehabilitation, particularly for severely to moderately impaired stroke patients. The objective of this study was to investigate the effects of intensive arm training on motor performance in four chronic stroke patients using the robot ARMin II. Methods ARMin II is an exoskeleton robot with six degrees of freedom (DOF moving shoulder, elbow and wrist joints. Four volunteers with chronic (≥ 12 months post-stroke left side hemi-paresis and different levels of motor severity were enrolled in the study. They received robot-assisted therapy over a period of eight weeks, three to four therapy sessions per week, each session of one hour. Patients 1 and 4 had four one-hour training sessions per week and patients 2 and 3 had three one-hour training sessions per week. Primary outcome variable was the Fugl-Meyer Score of the upper extremity Assessment (FMA, secondary outcomes were the Wolf Motor Function Test (WMFT, the Catherine Bergego Scale (CBS, the Maximal Voluntary Torques (MVTs and a questionnaire about ADL-tasks, progress, changes, motivation etc. Results Three out of four patients showed significant improvements (p Conclusion Data clearly indicate that intensive arm therapy with the robot ARMin II can significantly improve motor function of the paretic arm in some stroke patients, even those in a chronic state. The findings of the study provide a basis for a subsequent controlled randomized clinical trial.

  13. Development of a Stereo Vision Measurement System for a 3D Three-Axial Pneumatic Parallel Mechanism Robot Arm

    Directory of Open Access Journals (Sweden)

    Chien-Lun Hou

    2011-02-01

    Full Text Available In this paper, a stereo vision 3D position measurement system for a three-axial pneumatic parallel mechanism robot arm is presented. The stereo vision 3D position measurement system aims to measure the 3D trajectories of the end-effector of the robot arm. To track the end-effector of the robot arm, the circle detection algorithm is used to detect the desired target and the SAD algorithm is used to track the moving target and to search the corresponding target location along the conjugate epipolar line in the stereo pair. After camera calibration, both intrinsic and extrinsic parameters of the stereo rig can be obtained, so images can be rectified according to the camera parameters. Thus, through the epipolar rectification, the stereo matching process is reduced to a horizontal search along the conjugate epipolar line. Finally, 3D trajectories of the end-effector are computed by stereo triangulation. The experimental results show that the stereo vision 3D position measurement system proposed in this paper can successfully track and measure the fifth-order polynomial trajectory and sinusoidal trajectory of the end-effector of the three- axial pneumatic parallel mechanism robot arm.

  14. Research on the man in the loop control system of the robot arm based on gesture control

    Science.gov (United States)

    Xiao, Lifeng; Peng, Jinbao

    2017-03-01

    The Man in the loop control system of the robot arm based on gesture control research complex real-world environment, which requires the operator to continuously control and adjust the remote manipulator, as the background, completes the specific mission human in the loop entire system as the research object. This paper puts forward a kind of robot arm control system of Man in the loop based on gesture control, by robot arm control system based on gesture control and Virtual reality scene feedback to enhance immersion and integration of operator, to make operator really become a part of the whole control loop. This paper expounds how to construct a man in the loop control system of the robot arm based on gesture control. The system is a complex system of human computer cooperative control, but also people in the loop control problem areas. The new system solves the problems that the traditional method has no immersion feeling and the operation lever is unnatural, the adjustment time is long, and the data glove mode wears uncomfortable and the price is expensive.

  15. A soft body as a reservoir: case studies in a dynamic model of octopus-inspired soft robotic arm

    Science.gov (United States)

    Nakajima, Kohei; Hauser, Helmut; Kang, Rongjie; Guglielmino, Emanuele; Caldwell, Darwin G.; Pfeifer, Rolf

    2013-01-01

    The behaviors of the animals or embodied agents are characterized by the dynamic coupling between the brain, the body, and the environment. This implies that control, which is conventionally thought to be handled by the brain or a controller, can partially be outsourced to the physical body and the interaction with the environment. This idea has been demonstrated in a number of recently constructed robots, in particular from the field of “soft robotics”. Soft robots are made of a soft material introducing high-dimensionality, non-linearity, and elasticity, which often makes the robots difficult to control. Biological systems such as the octopus are mastering their complex bodies in highly sophisticated manners by capitalizing on their body dynamics. We will demonstrate that the structure of the octopus arm cannot only be exploited for generating behavior but also, in a sense, as a computational resource. By using a soft robotic arm inspired by the octopus we show in a number of experiments how control is partially incorporated into the physical arm's dynamics and how the arm's dynamics can be exploited to approximate non-linear dynamical systems and embed non-linear limit cycles. Future application scenarios as well as the implications of the results for the octopus biology are also discussed. PMID:23847526

  16. On-line trajectory planning of time-jerk optimal for robotic arms

    Directory of Open Access Journals (Sweden)

    Nadir Bendali

    2016-09-01

    Full Text Available A method based on the computation of the time intervals of the knots for time-jerk optimal planning under kinematic constraints of robot manipulators in predefined operations is described in this paper. In order to ensure that the resulting trajectory is smooth enough, a cost function containing a term proportional to the integral of the squared jerk (defined as the derivative of the acceleration along the trajectory is considered. Moreover, a second term, proportional to the total execution time, is added to the expression of the cost function. A Cubic Spline functions are then used to compose overall trajectory. This method can meet the requirements of a short execution time and low arm vibration of the manipulator and the simulation provides good results.

  17. Silhouette-based approach of 3D image reconstruction for automated image acquisition using robotic arm

    Science.gov (United States)

    Azhar, N.; Saad, W. H. M.; Manap, N. A.; Saad, N. M.; Syafeeza, A. R.

    2017-06-01

    This study presents the approach of 3D image reconstruction using an autonomous robotic arm for the image acquisition process. A low cost of the automated imaging platform is created using a pair of G15 servo motor connected in series to an Arduino UNO as a main microcontroller. Two sets of sequential images were obtained using different projection angle of the camera. The silhouette-based approach is used in this study for 3D reconstruction from the sequential images captured from several different angles of the object. Other than that, an analysis based on the effect of different number of sequential images on the accuracy of 3D model reconstruction was also carried out with a fixed projection angle of the camera. The effecting elements in the 3D reconstruction are discussed and the overall result of the analysis is concluded according to the prototype of imaging platform.

  18. The Use of Industrial Robot Arms for High Precision Patient Positioning

    International Nuclear Information System (INIS)

    Katuin, J.E.; Schreuder, A.N.; Starks, W.M.; Doskow, J.

    2003-01-01

    The Indiana University Cyclotron Facility (IUCF) is in the process of designing and building the Midwest Proton Radiation Institute (MPRI) [1]. The design process includes the development of several patient treatment systems. This paper discusses the use of two such systems that provide for the high precision positioning of a patient. They are the Patient Positioner System and the X-ray system. The Patient Positioner System positions an immobilized patient on a support device to a treatment position based on a prescribed Treatment Plan. The X-ray system uses an industrial robot arm to position a Digital Radiography Panel to acquire an X-ray image to verify the location of the prescribed treatment volume in a patient by comparing the acquired images with reference images obtained from the patient's Treatment plan

  19. A flexible 3D laser scanning system using a robotic arm

    Science.gov (United States)

    Fei, Zixuan; Zhou, Xiang; Gao, Xiaofei; Zhang, Guanliang

    2017-06-01

    In this paper, we present a flexible 3D scanning system based on a MEMS scanner mounted on an industrial arm with a turntable. This system has 7-degrees of freedom and is able to conduct a full field scan from any angle, suitable for scanning object with the complex shape. The existing non-contact 3D scanning system usually uses laser scanner that projects fixed stripe mounted on the Coordinate Measuring Machine (CMM) or industrial robot. These existing systems can't perform path planning without CAD models. The 3D scanning system presented in this paper can scan the object without CAD models, and we introduced this path planning method in the paper. We also propose a practical approach to calibrating the hand-in-eye system based on binocular stereo vision and analyzes the errors of the hand-eye calibration.

  20. Lower Robotic Arm Assembly Having a Plurality of Tendon Driven Digits

    Science.gov (United States)

    Guo, Raymond (Inventor); Bridgwater, Lyndon (Inventor); Nguyen, Vienny (Inventor); Radford, Nicolaus A. (Inventor)

    2016-01-01

    A lower robotic arm includes a base structure, a plurality of digits, and a plurality of tendons. The digits each include first, second, third, and fourth phalanges. Each digit is operatively attached to the base structure at the respective first phalange. A first joint operatively connects the first and second phalange to define a first axis, a second operatively connects the second and third phalange to define a second axis, and a third joint operatively connects the third and fourth phalange to define a third axis, such that the phalanges are selectively rotatable relative to the adjacent phalange, about the respective axis. The tendons are operatively connected to a respective one of the fourth phalanges. Each tendon selectively applies a first torque to the respective fourth phalange to urge the respective phalanges to rotate in a first direction about the respective axes.

  1. Robotic Exoskeletons: A Perspective for the Rehabilitation of Arm Coordination in Stroke Patients

    Science.gov (United States)

    Jarrassé, Nathanaël; Proietti, Tommaso; Crocher, Vincent; Robertson, Johanna; Sahbani, Anis; Morel, Guillaume; Roby-Brami, Agnès

    2014-01-01

    Upper-limb impairment after stroke is caused by weakness, loss of individual joint control, spasticity, and abnormal synergies. Upper-limb movement frequently involves abnormal, stereotyped, and fixed synergies, likely related to the increased use of sub-cortical networks following the stroke. The flexible coordination of the shoulder and elbow joints is also disrupted. New methods for motor learning, based on the stimulation of activity-dependent neural plasticity have been developed. These include robots that can adaptively assist active movements and generate many movement repetitions. However, most of these robots only control the movement of the hand in space. The aim of the present text is to analyze the potential of robotic exoskeletons to specifically rehabilitate joint motion and particularly inter-joint coordination. First, a review of studies on upper-limb coordination in stroke patients is presented and the potential for recovery of coordination is examined. Second, issues relating to the mechanical design of exoskeletons and the transmission of constraints between the robotic and human limbs are discussed. The third section considers the development of different methods to control exoskeletons: existing rehabilitation devices and approaches to the control and rehabilitation of joint coordinations are then reviewed, along with preliminary clinical results available. Finally, perspectives and future strategies for the design of control mechanisms for rehabilitation exoskeletons are discussed. PMID:25520638

  2. Kinematics and control of redundant robotic arm based on dielectric elastomer actuators

    Science.gov (United States)

    Branz, Francesco; Antonello, Andrea; Carron, Andrea; Carli, Ruggero; Francesconi, Alessandro

    2015-04-01

    Soft robotics is a promising field and its application to space mechanisms could represent a breakthrough in space technologies by enabling new operative scenarios (e.g. soft manipulators, capture systems). Dielectric Elastomers Actuators have been under deep study for a number of years and have shown several advantages that could be of key importance for space applications. Among such advantages the most notable are high conversion efficiency, distributed actuation, self-sensing capability, multi-degree-of-freedom design, light weight and low cost. The big potentialities of double cone actuators have been proven in terms of good performances (i.e. stroke and force/torque), ease of manufacturing and durability. In this work the kinematic, dynamic and control design of a two-joint redundant robotic arm is presented. Two double cone actuators are assembled in series to form a two-link design. Each joint has two degrees of freedom (one rotational and one translational) for a total of four. The arm is designed to move in a 2-D environment (i.e. the horizontal plane) with 4 DoF, consequently having two degrees of redundancy. The redundancy is exploited in order to minimize the joint loads. The kinematic design with redundant Jacobian inversion is presented. The selected control algorithm is described along with the results of a number of dynamic simulations that have been executed for performance verification. Finally, an experimental setup is presented based on a flexible structure that counteracts gravity during testing in order to better emulate future zero-gravity applications.

  3. Method of Grasping Control by Computing Internal and External Impedances for Two Robot Fingers, and Its Application to Admittance Control of a Robot Hand-Arm System

    Directory of Open Access Journals (Sweden)

    Jian Huang

    2015-08-01

    Full Text Available Impedance control is an important technology used in the grasping control of a robot hand. Numerous studies related to grasping algorithms have been reported in recent years, with the contact force between robot fingers and the object to be grasped being primarily discussed in most cases. Generally, a coupling effect occurs between the internal loop of the grasping operation and the external loop of the interaction with the environment when a multi-fingered robot hand is used to complete a contact task. Therefore, a robot hand cannot hold an object using a large external force to complete a wide range of tasks by applying the conventional method. In this paper, the coupling of the internal/external forces occurring in grasping operations using multiple fingers is analysed. Then, improved impedance control based on the previous method is proposed as an effective tool to solve the problem of grasping failure caused by single-finger contact. Furthermore, a method for applying the improved grasping algorithm to the admittance control of a robot hand-arm system is also proposed. The proposed method divides the impedance effect into the grasping control of the hand and the cooperative control of the arm, so that expanding the task space and increasing the flexibility of impedance adjustment can be achieved. Experiments were conducted to demonstrate the effectiveness of the proposed method.

  4. Dual Arm Work Platform teleoperated robotics system. Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-12-01

    The US Department of Energy (DOE) and the Federal Energy Technology Center (FETC) has developed a Large Scale Demonstration Project (LSDP) at the Chicago Pile-5 Research Reactor (CP-5) at Argonne National Laboratory-East (ANL). The objective of the LSDP is to demonstrate potentially beneficial Deactivation and Decommissioning (D and D) technologies in comparison with current baseline technologies. The Dual Arm Work Platform (DAWP) demonstration focused on the use of the DAWP to segment and dismantle the CP-5 reactor tank and surrounding bio-shield components (including the graphite block reflector, lead and boral sheeting) and performing some minor tasks best suited for the use of teleoperated robotics that were not evaluated in this demonstration. The DAWP system is not a commercially available product at this time. The CP-5 implementation was its first D and D application. The demonstration of the DAWP was to determine the areas on which improvements must be made to make this technology commercially viable. The results of the demonstration are included in this greenbook. It is the intention of the developers to incorporate lessons learned at this demonstration and current technological advancements in robotics into the next generation of the DAWP

  5. Robotic arm design for a remotely-deployed, in situ waste characterization probe

    International Nuclear Information System (INIS)

    Kress, R.L.; Jansen, J.F.; Haas, J.W.

    1991-01-01

    This paper describes some design considerations for a system which will combine robotics and laser spectroscopy to produce an in situ monitoring system for heterogeneous waste materials. The new system will provide faster, cheaper, safer, and more complete characterization of mixed solids and liquids stored in tanks and drums or buried in pits. A small, fiberoptic multiprobe that performs Raman and fluorescence measurements of wastes composed of a variety of organic and inorganic compounds will be described. Design considerations for a novel sensor platform that positions and stabilizes the multiprobe relative to the sampling point in order to make accurate spectroscopic measurements and deploys the sensor in hazardous environments with minimal risk to workers will be presented. The core of the platform will be a 3-Degrees-Of-Freedom (3-DOF), spherical coordinate end effector equipped with a proximity sensor that compensates for errors introduced by the flexible nature of the support arm. The platform can be adapted to operate the most robotic deployment systems used in hazardous environments. The multisensor probe will be coupled to remote, portable laser spectrometer systems by a fiber-optic bundle. 5 refs

  6. Robotic arm design for a remotely-deployed, in situ waste characterization probe

    International Nuclear Information System (INIS)

    Kress, Reid; Haas, John; Jansen, John

    1992-01-01

    This paper describes some design considerations for a system which will combine robotics and laser spectroscopy to produce an in situ monitoring system for heterogeneous waste materials. The new system will provide faster, cheaper) safer, and more complete characterization of mixed solids and liquids stored in tanks and drums or buried in pits. A small, fiberoptic multiprobe that performs Raman and fluorescence measurements of wastes composed of a variety of organic and inorganic compounds will be described. Design considerations for a novel sensor platform that positions and stabilizes the multiprobe relative to the sampling point in order to male accurate spectroscopic measurements and deploys the sensor in hazardous environments with minimal risk to workers will be presented. The core of (he platform will be a 3-Degrees-Of-Freedom (3-DOF), spherical coordinate end effector equipped with a proximity sensor that compensates for errors introduced by the flexible nature of the support arm. The platform can be adapted to operate with most robotic deployment systems used in hazardous environments. The multisensor probe will be coupled to remote, portable laser spectrometer systems by a fiber-optic bundle. (author)

  7. The HAAPI (Home Arm Assistance Progression Initiative) Trial: A Novel Robotics Delivery Approach in Stroke Rehabilitation.

    Science.gov (United States)

    Wolf, Steven L; Sahu, Komal; Bay, R Curtis; Buchanan, Sharon; Reiss, Aimee; Linder, Susan; Rosenfeldt, Anson; Alberts, Jay

    2015-01-01

    Geographical location, socioeconomic status, and logistics surrounding transportation impede access of poststroke individuals to comprehensive rehabilitative services. Robotic therapy may enhance telerehabilitation by delivering consistent and state-of-the art therapy while allowing remote monitoring and adjusting therapy for underserved populations. The Hand Mentor Pro (HMP) was incorporated within a home exercise program (HEP) to improve upper-extremity (UE) functional capabilities poststroke. To determine the efficacy of a home-based telemonitored robotic-assisted therapy as part of a HEP compared with a dose-matched HEP-only intervention among individuals less than 6 months poststroke and characterized as underserved. In this prospective, single-blinded, multisite, randomized controlled trial, 99 hemiparetic participants with limited access to UE rehabilitation were randomized to either (1) the experimental group, which received combined HEP and HMP for 3 h/d ×5 days ×8 weeks, or (2) the control group, which received HEP only at an identical dosage. Weekly communication between the supervising therapist and participant promoted compliance and progression of the HEP and HMP prescription. The Action Research Arm Test and Wolf Motor Function Test along with the Fugl-Meyer Assessment (UE) were primary and secondary outcome measures, respectively, undertaken before and after the interventions. Both groups demonstrated improvement across all UE outcomes. Robotic + HEP and HEP only were both effectively delivered remotely. There was no difference between groups in change in motor function over time. Additional research is necessary to determine the appropriate dosage of HMP and HEP. © The Author(s) 2015.

  8. Vibrotactile feedback for conveying object shape information as perceived by artificial sensing of robotic arm.

    Science.gov (United States)

    Khasnobish, Anwesha; Pal, Monalisa; Sardar, Dwaipayan; Tibarewala, D N; Konar, Amit

    2016-08-01

    This work is a preliminary study towards developing an alternative communication channel for conveying shape information to aid in recognition of items when tactile perception is hindered. Tactile data, acquired during object exploration by sensor fitted robot arm, are processed to recognize four basic geometric shapes. Patterns representing each shape, classified from tactile data, are generated using micro-controller-driven vibration motors which vibrotactually stimulate users to convey the particular shape information. These motors are attached on the subject's arm and their psychological (verbal) responses are recorded to assess the competence of the system to convey shape information to the user in form of vibrotactile stimulations. Object shapes are classified from tactile data with an average accuracy of 95.21 %. Three successive sessions of shape recognition from vibrotactile pattern depicted learning of the stimulus from subjects' psychological response which increased from 75 to 95 %. This observation substantiates the learning of vibrotactile stimulation in user over the sessions which in turn increase the system efficacy. The tactile sensing module and vibrotactile pattern generating module are integrated to complete the system whose operation is analysed in real-time. Thus, the work demonstrates a successful implementation of the complete schema of artificial tactile sensing system for object-shape recognition through vibrotactile stimulations.

  9. A Study of Accuracy and Time Delay for Bilateral Master-Slave Industrial Robotic Arm Manipulator System

    Directory of Open Access Journals (Sweden)

    Mansor Nuratiqa Natrah

    2018-01-01

    Full Text Available Bilateral master-slave industrial robotic arm manipulator system is an advanced technology used to help human to interact with environments that are unreachable to human, due to its remoteness or perilous. The system has been used in different areas such as tele-surgery, autonomous tele-operation for sea and space operation and handling explosive or high radiation operation fields. It is beneficial both for science and society. Remarkably, the system is not common and generally used in Malaysia. Likewise, the number of research conducted that focused about this technology in our country manufacturing industry are not yet discovered and existent. The implementation of this bilateral manipulator system in an industrial robot could be useful for industrial imminent and development over our country and people, specifically for production yield size and human operative. Hence, the study of bilateral robotic arm manipulator system in an industrial robot and analyzation of its performance and time delay in 3 differ controllers will be discussed to attest the efficiency and its effectiveness on the said design system. The experiment conducted was on KUKA youBot arm in V-Rep simulation with three different controllers (P, PD, PID.

  10. A Soft Body as a Reservoir: Case Studies in a Dynamic Model of Octopus-Inspired Soft Robotic Arm

    Directory of Open Access Journals (Sweden)

    Kohei eNakajima

    2013-07-01

    Full Text Available The behaviors of the animals or embodied agents are characterized by the dynamic coupling between the brain, the body, and the environment. This implies that control, which is conventionally thought to be handled by the brain or a controller, can partially be outsourced to the physical body and the interaction with the environment. This idea has been demonstrated in a number of recently constructed robots, in particular from the field of soft robotics. Soft robots are made of a soft material introducing high-dimensionality, nonlinearity, and elasticity, which often makes the robots difficult to control. Biological systems such as the octopus are mastering their complex bodies in highly sophisticated manners by capitalizing on their body dynamics. We will demonstrate that the structure of the octopus arm cannot only be exploited for generating behavior but also, in a sense, as a computational resource. By using a soft robotic arm inspired by the octopus we show in a number of experiments how control is partially incorporated into the physical arm’s dynamics and how the arm’s dynamics can be exploited to approximate nonlinear dynamical systems and embed nonlinear limit cycles. Future application scenarios as well as the implications of the results for the octopus biology are also discussed.

  11. Using Functional Electrical Stimulation Mediated by Iterative Learning Control and Robotics to Improve Arm Movement for People With Multiple Sclerosis.

    Science.gov (United States)

    Sampson, Patrica; Freeman, Chris; Coote, Susan; Demain, Sara; Feys, Peter; Meadmore, Katie; Hughes, Ann-Marie

    2016-02-01

    Few interventions address multiple sclerosis (MS) arm dysfunction but robotics and functional electrical stimulation (FES) appear promising. This paper investigates the feasibility of combining FES with passive robotic support during virtual reality (VR) training tasks to improve upper limb function in people with multiple sclerosis (pwMS). The system assists patients in following a specified trajectory path, employing an advanced model-based paradigm termed iterative learning control (ILC) to adjust the FES to improve accuracy and maximise voluntary effort. Reaching tasks were repeated six times with ILC learning the optimum control action from previous attempts. A convenience sample of five pwMS was recruited from local MS societies, and the intervention comprised 18 one-hour training sessions over 10 weeks. The accuracy of tracking performance without FES and the amount of FES delivered during training were analyzed using regression analysis. Clinical functioning of the arm was documented before and after treatment with standard tests. Statistically significant results following training included: improved accuracy of tracking performance both when assisted and unassisted by FES; reduction in maximum amount of FES needed to assist tracking; and less impairment in the proximal arm that was trained. The system was well tolerated by all participants with no increase in muscle fatigue reported. This study confirms the feasibility of FES combined with passive robot assistance as a potentially effective intervention to improve arm movement and control in pwMS and provides the basis for a follow-up study.

  12. Humans and Robots. Educational Brief.

    Science.gov (United States)

    National Aeronautics and Space Administration, Washington, DC.

    This brief discusses human movement and robotic human movement simulators. The activity for students in grades 5-12 provides a history of robotic movement and includes making an End Effector for the robotic arms used on the Space Shuttle and the International Space Station (ISS). (MVL)

  13. Adaptive neural control for dual-arm coordination of humanoid robot with unknown nonlinearities in output mechanism.

    Science.gov (United States)

    Liu, Zhi; Chen, Ci; Zhang, Yun; Chen, C L P

    2015-03-01

    To achieve an excellent dual-arm coordination of the humanoid robot, it is essential to deal with the nonlinearities existing in the system dynamics. The literatures so far on the humanoid robot control have a common assumption that the problem of output hysteresis could be ignored. However, in the practical applications, the output hysteresis is widely spread; and its existing limits the motion/force performances of the robotic system. In this paper, an adaptive neural control scheme, which takes the unknown output hysteresis and computational efficiency into account, is presented and investigated. In the controller design, the prior knowledge of system dynamics is assumed to be unknown. The motion error is guaranteed to converge to a small neighborhood of the origin by Lyapunov's stability theory. Simultaneously, the internal force is kept bounded and its error can be made arbitrarily small.

  14. A Behavior-Based Approach for Educational Robotics Activities

    Science.gov (United States)

    De Cristoforis, P.; Pedre, S.; Nitsche, M.; Fischer, T.; Pessacg, F.; Di Pietro, C.

    2013-01-01

    Educational robotics proposes the use of robots as a teaching resource that enables inexperienced students to approach topics in fields unrelated to robotics. In recent years, these activities have grown substantially in elementary and secondary school classrooms and also in outreach experiences to interest students in science, technology,…

  15. Intuitive wireless control of a robotic arm for people living with an upper body disability.

    Science.gov (United States)

    Fall, C L; Turgeon, P; Campeau-Lecours, A; Maheu, V; Boukadoum, M; Roy, S; Massicotte, D; Gosselin, C; Gosselin, B

    2015-08-01

    Assistive Technologies (ATs) also called extrinsic enablers are useful tools for people living with various disabilities. The key points when designing such useful devices not only concern their intended goal, but also the most suitable human-machine interface (HMI) that should be provided to users. This paper describes the design of a highly intuitive wireless controller for people living with upper body disabilities with a residual or complete control of their neck and their shoulders. Tested with JACO, a six-degree-of-freedom (6-DOF) assistive robotic arm with 3 flexible fingers on its end-effector, the system described in this article is made of low-cost commercial off-the-shelf components and allows a full emulation of JACO's standard controller, a 3 axis joystick with 7 user buttons. To do so, three nine-degree-of-freedom (9-DOF) inertial measurement units (IMUs) are connected to a microcontroller and help measuring the user's head and shoulders position, using a complementary filter approach. The results are then transmitted to a base-station via a 2.4-GHz low-power wireless transceiver and interpreted by the control algorithm running on a PC host. A dedicated software interface allows the user to quickly calibrate the controller, and translates the information into suitable commands for JACO. The proposed controller is thoroughly described, from the electronic design to implemented algorithms and user interfaces. Its performance and future improvements are discussed as well.

  16. Emulating a robotic manipulator arm with an hybrid motion-control system

    International Nuclear Information System (INIS)

    Aragón-González, G; León-Galicia, A; Noriega-Hernández, M; Salazar-Hueta, A

    2015-01-01

    A motion control system with four and 1/2 degrees of freedom, designed to move small objects within a 0.25 m3 space, parallel to a horizontal table, with high speed and performance similar to a robotic manipulator arm was built. The machine employs several actuators and control devices. Its main characteristic is to incorporate a servomotor, steeper motors, electromechanical and fluid power actuators and diverse control resources. A group of actuators arranged on a spherical coordinates system is attached to the servomotor platform. A linear pneumatic actuator with an angular grip provides the radial extension and load clamping capacity. Seven inductive proximity sensors and one encoder provide feedback, for operating the actuators under closed loop conditions. Communication between the sensors and control devices is organized by a PLC. A touch screen allows governing the system remotely, easily and interactively, without knowing the specific programming language of each control component. The graphic environment on the touch screen guides the user to design and store control programs, establishing coordinated automatic routines for moving objects in space, simulation and implementation of industrial positioning or machining processes

  17. A Proposal for Automatic Fruit Harvesting by Combining a Low Cost Stereovision Camera and a Robotic Arm

    Science.gov (United States)

    Font, Davinia; Pallejà, Tomàs; Tresanchez, Marcel; Runcan, David; Moreno, Javier; Martínez, Dani; Teixidó, Mercè; Palacín, Jordi

    2014-01-01

    This paper proposes the development of an automatic fruit harvesting system by combining a low cost stereovision camera and a robotic arm placed in the gripper tool. The stereovision camera is used to estimate the size, distance and position of the fruits whereas the robotic arm is used to mechanically pickup the fruits. The low cost stereovision system has been tested in laboratory conditions with a reference small object, an apple and a pear at 10 different intermediate distances from the camera. The average distance error was from 4% to 5%, and the average diameter error was up to 30% in the case of a small object and in a range from 2% to 6% in the case of a pear and an apple. The stereovision system has been attached to the gripper tool in order to obtain relative distance, orientation and size of the fruit. The harvesting stage requires the initial fruit location, the computation of the inverse kinematics of the robotic arm in order to place the gripper tool in front of the fruit, and a final pickup approach by iteratively adjusting the vertical and horizontal position of the gripper tool in a closed visual loop. The complete system has been tested in controlled laboratory conditions with uniform illumination applied to the fruits. As a future work, this system will be tested and improved in conventional outdoor farming conditions. PMID:24984059

  18. A Proposal for Automatic Fruit Harvesting by Combining a Low Cost Stereovision Camera and a Robotic Arm

    Directory of Open Access Journals (Sweden)

    Davinia Font

    2014-06-01

    Full Text Available This paper proposes the development of an automatic fruit harvesting system by combining a low cost stereovision camera and a robotic arm placed in the gripper tool. The stereovision camera is used to estimate the size, distance and position of the fruits whereas the robotic arm is used to mechanically pickup the fruits. The low cost stereovision system has been tested in laboratory conditions with a reference small object, an apple and a pear at 10 different intermediate distances from the camera. The average distance error was from 4% to 5%, and the average diameter error was up to 30% in the case of a small object and in a range from 2% to 6% in the case of a pear and an apple. The stereovision system has been attached to the gripper tool in order to obtain relative distance, orientation and size of the fruit. The harvesting stage requires the initial fruit location, the computation of the inverse kinematics of the robotic arm in order to place the gripper tool in front of the fruit, and a final pickup approach by iteratively adjusting the vertical and horizontal position of the gripper tool in a closed visual loop. The complete system has been tested in controlled laboratory conditions with uniform illumination applied to the fruits. As a future work, this system will be tested and improved in conventional outdoor farming conditions.

  19. Pick-up, transport and release of a molecular cargo using a small-molecule robotic arm

    Science.gov (United States)

    Kassem, Salma; Lee, Alan T. L.; Leigh, David A.; Markevicius, Augustinas; Solà, Jordi

    2016-02-01

    Modern-day factory assembly lines often feature robots that pick up, reposition and connect components in a programmed manner. The idea of manipulating molecular fragments in a similar way has to date only been explored using biological building blocks (specifically DNA). Here, we report on a wholly artificial small-molecule robotic arm capable of selectively transporting a molecular cargo in either direction between two spatially distinct, chemically similar, sites on a molecular platform. The arm picks up/releases a 3-mercaptopropanehydrazide cargo by formation/breakage of a disulfide bond, while dynamic hydrazone chemistry controls the cargo binding to the platform. Transport is controlled by selectively inducing conformational and configurational changes within an embedded hydrazone rotary switch that steers the robotic arm. In a three-stage operation, 79-85% of 3-mercaptopropanehydrazide molecules are transported in either (chosen) direction between the two platform sites, without the cargo at any time fully dissociating from the machine nor exchanging with other molecules in the bulk.

  20. Active MRI tracking for robotic assisted FUS

    Science.gov (United States)

    Xiao, Xu; Huang, Zhihong; Melzer, Andreas

    2017-03-01

    MR guided FUS is a noninvasive method producing thermal necrosis at the position of tumors with high accuracy and temperature control. Because the typical size of the ultrasound focus is smaller than the area of interested treatment tissues, focus repositioning become necessary to achieve multiple sonications to cover the whole targeted area. Using MR compatible mechanical actuators could help the ultrasound beam to reach a wider treatment range than using electrical beam steering technique and more flexibility in position the transducer. An active MR tracking technique was combined into the MRgFUS system to help locating the position of the mechanical actuator and the FUS transducer. For this study, a precise agar reference model was designed and fabricated to test the performance of the active tracking technique when it was used on the MR-compatible robotics InnoMotion™ (IBSMM, Engineering spol. s r.o. / Ltd, Czech Republic). The precision, tracking range and positioning speed of the combined robotic FUS system were evaluated in this study. Compared to the existing MR guided HIFU systems, the combined robotic system with active tracking techniques provides a potential that allows the FUS treatment to operate in a larger spatial range and with a faster speed, which is one of the main challenges for organ motion tracking.

  1. Human-Like Behavior of Robot Arms: General Considerations and the Handwriting Task-Part I: Mathematical Description of Human-Like Motion: Distributed Positioning and Virtual Fatigue

    NARCIS (Netherlands)

    Potkonjak, V.; Tzafestas, S.; Kostic, D.; Djordjevic, G.

    2001-01-01

    This two-part paper is concerned with the analysis and achievement of human-like behavior by robot arms (manipulators). The analysis involves three issues: (i) the resolution of the inverse kinematics problem of redundant robots, (ii) the separation of the end-effector's motion into two components,

  2. Active Vision for Humanoid Robots

    NARCIS (Netherlands)

    Wang, X.

    2015-01-01

    Human perception is an active process. By altering its viewpoint rather than passively observing surroundings and by operating on sequences of images rather than on a single frame, the human visual system has the ability to explore the most relevant information based on knowledge, therefore when

  3. Patterns of arm muscle activation involved in octopus reaching movements.

    Science.gov (United States)

    Gutfreund, Y; Flash, T; Fiorito, G; Hochner, B

    1998-08-01

    The extreme flexibility of the octopus arm allows it to perform many different movements, yet octopuses reach toward a target in a stereotyped manner using a basic invariant motor structure: a bend traveling from the base of the arm toward the tip (Gutfreund et al., 1996a). To study the neuronal control of these movements, arm muscle activation [electromyogram (EMG)] was measured together with the kinematics of reaching movements. The traveling bend is associated with a propagating wave of muscle activation, with maximal muscle activation slightly preceding the traveling bend. Tonic activation was occasionally maintained afterward. Correlation of the EMG signals with the kinematic variables (velocities and accelerations) reveals that a significant part of the kinematic variability can be explained by the level of muscle activation. Furthermore, the EMG level measured during the initial stages of movement predicts the peak velocity attained toward the end of the reaching movement. These results suggest that feed-forward motor commands play an important role in the control of movement velocity and that simple adjustment of the excitation levels at the initial stages of the movement can set the velocity profile of the whole movement. A simple model of octopus arm extension is proposed in which the driving force is set initially and is then decreased in proportion to arm diameter at the bend. The model qualitatively reproduces the typical velocity profiles of octopus reaching movements, suggesting a simple control mechanism for bend propagation in the octopus arm.

  4. Energy Optimal Trajectories in Human Arm Motion Aiming for Assistive Robots

    Directory of Open Access Journals (Sweden)

    Lelai Zhou

    2017-01-01

    Full Text Available The energy expenditure in human arm has been of great interests for seeking optimal human arm trajectories. This paper presents a new way for calculating metabolic energy consumption of human arm motions. The purpose is to reveal the relationship between the energy consumption and the trajectory of arm motion, and further, the acceleration and arm orientation contributions. Human arm motion in horizontal plane is investigated by virtue of Qualisys motion capture system. The motion data is post-processed by a biomechanical model to obtain the metabolic expenditure. Results on the arm motion kinematics, dynamics and metabolic energy consumption, are included.

  5. A cost-effective intelligent robotic system with dual-arm dexterous coordination and real-time vision

    Science.gov (United States)

    Marzwell, Neville I.; Chen, Alexander Y. K.

    1991-01-01

    articulated arms, one movable robot head, and two charged coupled device (CCD) cameras for producing the stereoscopic views, and articulated cylindrical-type lower body, and an optional mobile base. A functional prototype is demonstrated.

  6. Curiosity’s robotic arm-mounted Mars Hand Lens Imager (MAHLI): Characterization and calibration status

    Science.gov (United States)

    Edgett, Kenneth S.; Caplinger, Michael A.; Maki, Justin N.; Ravine, Michael A.; Ghaemi, F. Tony; McNair, Sean; Herkenhoff, Kenneth E.; Duston, Brian M.; Wilson, Reg G.; Yingst, R. Aileen; Kennedy, Megan R.; Minitti, Michelle E.; Sengstacken, Aaron J.; Supulver, Kimberley D.; Lipkaman, Leslie J.; Krezoski, Gillian M.; McBride, Marie J.; Jones, Tessa L.; Nixon, Brian E.; Van Beek, Jason K.; Krysak, Daniel J.; Kirk, Randolph L.

    2015-01-01

    MAHLI (Mars Hand Lens Imager) is a 2-megapixel, Bayer pattern color CCD camera with a macro lens mounted on a rotatable turret at the end of the 2-meters-long robotic arm aboard the Mars Science Laboratory rover, Curiosity. The camera includes white and longwave ultraviolet LEDs to illuminate targets at night. Onboard data processing services include focus stack merging and data compression. Here we report on the results and status of MAHLI characterization and calibration, covering the pre-launch period from August 2008 through the early months of the extended surface mission through February 2015. Since landing in Gale crater in August 2012, MAHLI has been used for a wide range of science and engineering applications, including distinction among a variety of mafic, siliciclastic sedimentary rocks; investigation of grain-scale rock, regolith, and eolian sediment textures and structures; imaging of the landscape; inspection and monitoring of rover and science instrument hardware concerns; and supporting geologic sample selection, extraction, analysis, delivery, and documentation. The camera has a dust cover and focus mechanism actuated by a single stepper motor. The transparent cover was coated with a thin film of dust during landing, thus MAHLI is usually operated with the cover open. The camera focuses over a range from a working distance of 2.04 cm to infinity; the highest resolution images are at 13.9 µm per pixel; images acquired from 6.9 cm show features at the same scale as the Mars Exploration Rover Microscopic Imagers at 31 µm/pixel; and 100 µm/pixel is achieved at a working distance of ~26.5 cm. The very highest resolution images returned from Mars permit distinction of high contrast silt grains in the 30–40 µm size range. MAHLI has performed well; the images need no calibration in order to achieve most of the investigation’s science and engineering goals. The positioning and repeatability of robotic arm placement of the MAHLI camera head have

  7. Corticospinal contribution to arm muscle activity during human walking

    DEFF Research Database (Denmark)

    Barthélemy, Dorothy; Nielsen, Jens Bo

    2010-01-01

    inhibitory interneurones, the suppression is in all likelihood caused by removal of a corticospinal contribution to the ongoing EMG activity. The data thus suggest that the motor cortex makes an active contribution, through the corticospinal tract, to the ongoing EMG activity in arm muscles during walking....

  8. Human-like behavior of robot arms: general considerations and the handwriting task-part II: The robot arm in handwriting

    NARCIS (Netherlands)

    Potkonjak, V.; Kostic, D.; Tzafestas, S.; Popovic, M.; Lazarevic, M.; Djordjevic, G.

    2001-01-01

    This paper (Part II) investigates the motion of a redundant anthropomorphic arm during the writing task. Two approaches are applied. The first is based on the concept of distributed positioning which is suitable to model the "writing" task before the occurrence of fatigue symptoms. The second

  9. Sedimentological Investigations of the Martian Surface using the Mars 2001 Robotic Arm Camera and MECA Optical Microscope

    Science.gov (United States)

    Rice, J. W., Jr.; Smith, P. H.; Marshall, J. R.

    1999-01-01

    The first microscopic sedimentological studies of the Martian surface will commence with the landing of the Mars Polar Lander (MPL) December 3, 1999. The Robotic Arm Camera (RAC) has a resolution of 25 um/p which will permit detailed micromorphological analysis of surface and subsurface materials. The Robotic Ann will be able to dig up to 50 cm below the surface. The walls of the trench will also be inspected by RAC to look for evidence of stratigraphic and / or sedimentological relationships. The 2001 Mars Lander will build upon and expand the sedimentological research begun by the RAC on MPL. This will be accomplished by: (1) Macroscopic (dm to cm): Descent Imager, Pancam, RAC; (2) Microscopic (mm to um RAC, MECA Optical Microscope (Figure 2), AFM This paper will focus on investigations that can be conducted by the RAC and MECA Optical Microscope.

  10. Robotics

    Science.gov (United States)

    Popov, E. P.; Iurevich, E. I.

    The history and the current status of robotics are reviewed, as are the design, operation, and principal applications of industrial robots. Attention is given to programmable robots, robots with adaptive control and elements of artificial intelligence, and remotely controlled robots. The applications of robots discussed include mechanical engineering, cargo handling during transportation and storage, mining, and metallurgy. The future prospects of robotics are briefly outlined.

  11. Mobile Robotics Activities in DOE Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Ron Lujan; Jerry Harbour; John T. Feddema; Sharon Bailey; Jacob Barhen; David Reister

    2005-03-01

    This paper will briefly outline major activities in Department of Energy (DOE) Laboratories focused on mobile platforms, both Unmanned Ground Vehicles (UGV’s) as well as Unmanned Air Vehicles (UAV’s). The activities will be discussed in the context of the science and technology construct used by the DOE Technology Roadmap for Robotics and Intelligent Machines (RIM)1 published in 1998; namely, Perception, Reasoning, Action, and Integration. The activities to be discussed span from research and development to deployment in field operations. The activities support customers in other agencies. The discussion of "perception" will include hyperspectral sensors, complex patterns discrimination, multisensor fusion and advances in LADAR technologies, including real-world perception. "Reasoning" activities to be covered include cooperative controls, distributed systems, ad-hoc networks, platform-centric intelligence, and adaptable communications. The paper will discuss "action" activities such as advanced mobility and various air and ground platforms. In the RIM construct, "integration" includes the Human-Machine Integration. Accordingly the paper will discuss adjustable autonomy and the collaboration of operator(s) with distributed UGV’s and UAV’s. Integration also refers to the applications of these technologies into systems to perform operations such as perimeter surveillance, large-area monitoring and reconnaissance. Unique facilities and test beds for advanced mobile systems will be described. Given that this paper is an overview, rather than delve into specific detail in these activities, other more exhaustive references and sources will be cited extensively.

  12. Robotics at Savannah River site: activity report

    International Nuclear Information System (INIS)

    Byrd, J.S.

    1984-09-01

    The objectives of the Robotics Technology Group at the Savannah River Laboratory are to employ modern industrial robots and to develop unique automation and robotic systems to enhance process operations at the Savannah River site (SRP and SRL). The incentives are to improve safety, reduce personnel radiation exposure, improve product quality and productivity, and to reduce operating costs. During the past year robotic systems have been installed to fill chemical dilution vials in a SRP laboratory at 772-F and remove radioactive waste materials in the SRL Californium Production Facility at 773-A. A robotic system to lubricate an extrusion press has been developed and demonstrated in the SRL robotics laboratory and is scheduled for installation at the 321-M fuel fabrication area. A mobile robot was employed by SRP for a radiation monitoring task at a waste tank top in H-Area. Several other robots are installed in the SRL robotics laboratories and application development programs are underway. The status of these applications is presented in this report

  13. Robotic-assisted partial nephrectomy: surgical technique using a 3-arm approach and sliding-clip renorrhaphy

    Directory of Open Access Journals (Sweden)

    Jose M. Cabello

    2009-04-01

    Full Text Available INTRODUCTION: For the treatment of renal tumors, minimally invasive nephron-sparing surgery has become increasingly performed due to proven efficiency and excellent functional and oncological outcomes. The introduction of robotics into urologic laparoscopic surgery has allowed surgeons to perform challenging procedures in a reliable and reproducible manner. We present our surgical technique for robotic assisted partial nephrectomy (RPN using a 3-arm approach, including a sliding-clip renorrhaphy. MATERIAL AND METHODS: Our RPN technique is presented which describes the trocar positioning, hilar dissection, tumor identification using intraoperative ultrasound for margin determination, selective vascular clamping, tumor resection, and reconstruction using a sliding-clip technique. CONCLUSION: RPN using a sliding-clip renorrhaphy is a valid and reproducible surgical technique that reduces the challenge of the procedure by taking advantage of the enhanced visualization and control afforded by the robot. The renorrhaphy described is performed under complete control of the console surgeon, and has demonstrated a reduction in the warm ischemia times in our series.

  14. Robotic assisted laparoscopic colectomy.

    LENUS (Irish Health Repository)

    Pandalai, S

    2010-06-01

    Robotic surgery has evolved over the last decade to compensate for limitations in human dexterity. It avoids the need for a trained assistant while decreasing error rates such as perforations. The nature of the robotic assistance varies from voice activated camera control to more elaborate telerobotic systems such as the Zeus and the Da Vinci where the surgeon controls the robotic arms using a console. Herein, we report the first series of robotic assisted colectomies in Ireland using a voice activated camera control system.

  15. Using Arm and Hand Gestures to Command Robots during Stealth Operations

    Science.gov (United States)

    Stoica, Adrian; Assad, Chris; Wolf, Michael; You, Ki Sung; Pavone, Marco; Huntsberger, Terry; Iwashita, Yumi

    2012-01-01

    Command of support robots by the warfighter requires intuitive interfaces to quickly communicate high degree-of-freedom (DOF) information while leaving the hands unencumbered. Stealth operations rule out voice commands and vision-based gesture interpretation techniques, as they often entail silent operations at night or in other low visibility conditions. Targeted at using bio-signal inputs to set navigation and manipulation goals for the robot (say, simply by pointing), we developed a system based on an electromyography (EMG) "BioSleeve", a high density sensor array for robust, practical signal collection from forearm muscles. The EMG sensor array data is fused with inertial measurement unit (IMU) data. This paper describes the BioSleeve system and presents initial results of decoding robot commands from the EMG and IMU data using a BioSleeve prototype with up to sixteen bipolar surface EMG sensors. The BioSleeve is demonstrated on the recognition of static hand positions (e.g. palm facing front, fingers upwards) and on dynamic gestures (e.g. hand wave). In preliminary experiments, over 90% correct recognition was achieved on five static and nine dynamic gestures. We use the BioSleeve to control a team of five LANdroid robots in individual and group/squad behaviors. We define a gesture composition mechanism that allows the specification of complex robot behaviors with only a small vocabulary of gestures/commands, and we illustrate it with a set of complex orders.

  16. Autonomous Motion Learning for Intra-Vehicular Activity Space Robot

    Science.gov (United States)

    Watanabe, Yutaka; Yairi, Takehisa; Machida, Kazuo

    Space robots will be needed in the future space missions. So far, many types of space robots have been developed, but in particular, Intra-Vehicular Activity (IVA) space robots that support human activities should be developed to reduce human-risks in space. In this paper, we study the motion learning method of an IVA space robot with the multi-link mechanism. The advantage point is that this space robot moves using reaction force of the multi-link mechanism and contact forces from the wall as space walking of an astronaut, not to use a propulsion. The control approach is determined based on a reinforcement learning with the actor-critic algorithm. We demonstrate to clear effectiveness of this approach using a 5-link space robot model by simulation. First, we simulate that a space robot learn the motion control including contact phase in two dimensional case. Next, we simulate that a space robot learn the motion control changing base attitude in three dimensional case.

  17. Design and Nonlinear Control of a 2-DOF Flexible Parallel Humanoid Arm Joint Robot

    Directory of Open Access Journals (Sweden)

    Leijie Jiang

    2017-01-01

    Full Text Available The paper focuses on the design and nonlinear control of the humanoid wrist/shoulder joint based on the cable-driven parallel mechanism which can realize roll and pitch movement. In view of the existence of the flexible parts in the mechanism, it is necessary to solve the vibration control of the flexible wrist/shoulder joint. In this paper, a cable-driven parallel robot platform is developed for the experiment study of the humanoid wrist/shoulder joint. And the dynamic model of the mechanism is formulated by using the coupling theory of the flexible body’s large global motion and small flexible deformation. Based on derived dynamics, antivibration control of the joint robot is studied with a nonlinear control method. Finally, simulations and experiments were performed to validate the feasibility of the developed parallel robot prototype and the proposed control scheme.

  18. Design and Development of an Automatic Tool Changer for an Articulated Robot Arm

    International Nuclear Information System (INIS)

    Ambrosio, H; Karamanoglu, M

    2014-01-01

    In the creative industries, the length of time between the ideation stage and the making of physical objects is decreasing due to the use of CAD/CAM systems and adicitive manufacturing. Natural anisotropic materials, such as solid wood can also be transformed using CAD/CAM systems, but only with subtractive processes such as machining with CNC routers. Whilst some 3 axis CNC routing machines are affordable to buy and widely available, more flexible 5 axis routing machines still present themselves as a too big investment for small companies. Small refurbished articulated robots can be a cheaper alternative but they require a light end-effector. This paper presents a new lightweight tool changer that converts a small 3kg payload 6 DOF robot into a robot apprentice able to machine wood and similar soft materials

  19. Design and Development of an Automatic Tool Changer for an Articulated Robot Arm

    Science.gov (United States)

    Ambrosio, H.; Karamanoglu, M.

    2014-07-01

    In the creative industries, the length of time between the ideation stage and the making of physical objects is decreasing due to the use of CAD/CAM systems and adicitive manufacturing. Natural anisotropic materials, such as solid wood can also be transformed using CAD/CAM systems, but only with subtractive processes such as machining with CNC routers. Whilst some 3 axis CNC routing machines are affordable to buy and widely available, more flexible 5 axis routing machines still present themselves as a too big investment for small companies. Small refurbished articulated robots can be a cheaper alternative but they require a light end-effector. This paper presents a new lightweight tool changer that converts a small 3kg payload 6 DOF robot into a robot apprentice able to machine wood and similar soft materials.

  20. An Interactive Human Interface Arm Robot with the Development of Food Aid

    Directory of Open Access Journals (Sweden)

    NASHWAN D. Zaki

    2012-03-01

    Full Text Available A robotic system for the disabled who needs supports at meal is proposed. A feature of this system is that the robotic aid system can communicate with the operator using the speech recognition and speech synthesis functions. Another feature is that the robotic aid system uses an image processing, and by doing this the system can recognize the environmental situations of the dishes, cups and so on. Due to this image processing function, the operator does not need to specify the position and the posture of the dishes and target objects. Furthermore, combination communication between speech and image processing will enables a friendly man-machine to communicate with each other, since speech and visual information are essential in the human communication.

  1. Experimental Test Rig for Optimal Control of Flexible Space Robotic Arms

    Science.gov (United States)

    2016-12-01

    the test bed design. A single link arm with a torsional, helical spring at the base was finalized to investigate the effects of coupling due to...test bed design. A single link arm with a torsional, helical spring at the base was finalized to investigate the effects of coupling due to movement...Source: [4]. A challenge with space systems is that it costs a lot of money to put a satellite or spacecraft into space. Estimates to send one kilogram

  2. Rough terrain motion planning for actively reconfigurable mobile robots

    Energy Technology Data Exchange (ETDEWEB)

    Brunner, Michael

    2015-02-05

    In the aftermath of the Tohoku earthquake and the nuclear meltdown at the power plant of Fukushima Daiichi in 2011, reconfigurable robots like the iRobot Packbot were deployed. Instead of humans, the robots were used to investigate contaminated areas. Other incidents are the two major earthquakes in Northern Italy in May 2012. Besides many casualties, a large number of historical buildings was severely damaged. Due to the imminent danger of collapse, it was too dangerous for rescue personnel to enter many of the buildings. Therefore, the sites were inspected by reconfigurable robots, which are able to traverse the rubble and debris of the partially destroyed buildings. This thesis develops a navigation system enabling wheeled and tracked robots to safely traverse rough terrain and challenging structures. It consists of a planning mechanism and a controller. The focus of this thesis, however, is on the contribution to motion planning. The planning scheme employs a hierarchical approach to motion planning for actively reconfigurable robots in rough environments. Using a map of the environment the algorithm estimates the traversability under the consideration of uncertainties. Based on this analysis, an initial path search determines an approximate solution with respect to the robot's operating limits.Subsequently, a detailed planning step refines the initial path where it is required. The refinement step considers the robot's actuators and stability in addition to the quantities of the first search. Determining the robot-terrain interaction is very important in rough terrain. This thesis presents two path refinement approaches: a deterministic and a randomized approach. The experimental evaluation investigates the separate components of the planning scheme, the robot-terrain interaction for instance.In simulation as well as in real world experiments the evaluation demonstrates the necessity of such a planning algorithm in rough terrain and it provides

  3. Rough terrain motion planning for actively reconfigurable mobile robots

    International Nuclear Information System (INIS)

    Brunner, Michael

    2015-01-01

    In the aftermath of the Tohoku earthquake and the nuclear meltdown at the power plant of Fukushima Daiichi in 2011, reconfigurable robots like the iRobot Packbot were deployed. Instead of humans, the robots were used to investigate contaminated areas. Other incidents are the two major earthquakes in Northern Italy in May 2012. Besides many casualties, a large number of historical buildings was severely damaged. Due to the imminent danger of collapse, it was too dangerous for rescue personnel to enter many of the buildings. Therefore, the sites were inspected by reconfigurable robots, which are able to traverse the rubble and debris of the partially destroyed buildings. This thesis develops a navigation system enabling wheeled and tracked robots to safely traverse rough terrain and challenging structures. It consists of a planning mechanism and a controller. The focus of this thesis, however, is on the contribution to motion planning. The planning scheme employs a hierarchical approach to motion planning for actively reconfigurable robots in rough environments. Using a map of the environment the algorithm estimates the traversability under the consideration of uncertainties. Based on this analysis, an initial path search determines an approximate solution with respect to the robot's operating limits.Subsequently, a detailed planning step refines the initial path where it is required. The refinement step considers the robot's actuators and stability in addition to the quantities of the first search. Determining the robot-terrain interaction is very important in rough terrain. This thesis presents two path refinement approaches: a deterministic and a randomized approach. The experimental evaluation investigates the separate components of the planning scheme, the robot-terrain interaction for instance.In simulation as well as in real world experiments the evaluation demonstrates the necessity of such a planning algorithm in rough terrain and it provides

  4. Vision-based control of robotic arm with 6 degrees of freedom

    OpenAIRE

    Versleegers, Wim

    2014-01-01

    This paper studies the procedure to program a vertically articulated robot with six degrees of freedom, the Mitsubishi Melfa RV-2SD, with Matlab. A major drawback of the programming software provided by Mitsubishi is that it barely allows the use of vision-based programming. The amount of useable cameras is limited and moreover, the cameras are very expensive. Using Matlab, these limitations could be overcome. However there is no direct way to control the robot with Matlab. The goal of this p...

  5. A new hybrid machine design for a 6 DOF industrial robot arm

    CSIR Research Space (South Africa)

    Shaik, AA

    2012-05-01

    Full Text Available of units sold since 1960 amounted to more than 2 230 000, and the IFR (International Federation of Robotics) estimates the total number of operational industrial robots worldwide to be between 1 021 000 and 1 300 000 units at the end of 2009. [Exec sum... productivity to be competitive on the global market and the competition for market share in rising consumer markets. [IFR 1] The main drivers for the strong recovery in 2010 were automotive manufacturers and the electronics industry. In addition...

  6. Comparison of three-dimensional, assist-as-needed robotic arm/hand movement training provided with Pneu-WREX to conventional tabletop therapy after chronic stroke.

    Science.gov (United States)

    Reinkensmeyer, David J; Wolbrecht, Eric T; Chan, Vicky; Chou, Cathy; Cramer, Steven C; Bobrow, James E

    2012-11-01

    Robot-assisted movement training can help individuals with stroke reduce arm and hand impairment, but robot therapy is typically only about as effective as conventional therapy. Refining the way that robots assist during training may make them more effective than conventional therapy. Here, the authors measured the therapeutic effect of a robot that required individuals with a stroke to achieve virtual tasks in three dimensions against gravity. The robot continuously estimated how much assistance patients needed to perform the tasks and provided slightly less assistance than needed to reduce patient slacking. Individuals with a chronic stroke (n = 26; baseline upper limb Fugl-Meyer score, 23 ± 8) were randomized into two groups and underwent 24 one-hour training sessions over 2 mos. One group received the assist-as-needed robot training and the other received conventional tabletop therapy with the supervision of a physical therapist. Training helped both groups significantly reduce their motor impairment, as measured by the primary outcome measure, the Fugl-Meyer score, but the improvement was small (3.0 ± 4.9 points for robot therapy vs. 0.9 ± 1.7 for conventional therapy). There was a trend for greater reduction for the robot-trained group (P = 0.07). The robot group largely sustained this gain at the 3-mo follow-up. The robot-trained group also experienced significant improvements in Box and Blocks score and hand grip strength, whereas the control group did not, but these improvements were not sustained at follow-up. In addition, the robot-trained group showed a trend toward greater improvement in sensory function, as measured by the Nottingham Sensory Test (P = 0.06). These results suggest that in patients with chronic stroke and moderate-severe deficits, assisting in three-dimensional virtual tasks with an assist-as-needed controller may make robotic training more effective than conventional tabletop training.

  7. Task-driven orbit design and implementation on a robotic C-arm system for cone-beam CT

    Science.gov (United States)

    Ouadah, S.; Jacobson, M.; Stayman, J. W.; Ehtiati, T.; Weiss, C.; Siewerdsen, J. H.

    2017-03-01

    Purpose: This work applies task-driven optimization to the design of non-circular orbits that maximize imaging performance for a particular imaging task. First implementation of task-driven imaging on a clinical robotic C-arm system is demonstrated, and a framework for orbit calculation is described and evaluated. Methods: We implemented a task-driven imaging framework to optimize orbit parameters that maximize detectability index d'. This framework utilizes a specified Fourier domain task function and an analytical model for system spatial resolution and noise. Two experiments were conducted to test the framework. First, a simple task was considered consisting of frequencies lying entirely on the fz-axis (e.g., discrimination of structures oriented parallel to the central axial plane), and a "circle + arc" orbit was incorporated into the framework as a means to improve sampling of these frequencies, and thereby increase task-based detectability. The orbit was implemented on a robotic C-arm (Artis Zeego, Siemens Healthcare). A second task considered visualization of a cochlear implant simulated within a head phantom, with spatial frequency response emphasizing high-frequency content in the (fy, fz) plane of the cochlea. An optimal orbit was computed using the task-driven framework, and the resulting image was compared to that for a circular orbit. Results: For the fz-axis task, the circle + arc orbit was shown to increase d' by a factor of 1.20, with an improvement of 0.71 mm in a 3D edge-spread measurement for edges located far from the central plane and a decrease in streak artifacts compared to a circular orbit. For the cochlear implant task, the resulting orbit favored complementary views of high tilt angles in a 360° orbit, and d' was increased by a factor of 1.83. Conclusions: This work shows that a prospective definition of imaging task can be used to optimize source-detector orbit and improve imaging performance. The method was implemented for execution of

  8. Vision-Based Recognition of Activities by a Humanoid Robot

    Directory of Open Access Journals (Sweden)

    Mounîm A. El-Yacoubi

    2015-12-01

    Full Text Available We present an autonomous assistive robotic system for human activity recognition from video sequences. Due to the large variability inherent to video capture from a non-fixed robot (as opposed to a fixed camera, as well as the robot's limited computing resources, implementation has been guided by robustness to this variability and by memory and computing speed efficiency. To accommodate motion speed variability across users, we encode motion using dense interest point trajectories. Our recognition model harnesses the dense interest point bag-of-words representation through an intersection kernel-based SVM that better accommodates the large intra-class variability stemming from a robot operating in different locations and conditions. To contextually assess the engine as implemented in the robot, we compare it with the most recent approaches of human action recognition performed on public datasets (non-robot-based, including a novel approach of our own that is based on a two-layer SVM-hidden conditional random field sequential recognition model. The latter's performance is among the best within the recent state of the art. We show that our robot-based recognition engine, while less accurate than the sequential model, nonetheless shows good performances, especially given the adverse test conditions of the robot, relative to those of a fixed camera.

  9. 2D-3D radiograph to cone-beam computed tomography (CBCT) registration for C-arm image-guided robotic surgery.

    Science.gov (United States)

    Liu, Wen Pei; Otake, Yoshito; Azizian, Mahdi; Wagner, Oliver J; Sorger, Jonathan M; Armand, Mehran; Taylor, Russell H

    2015-08-01

    C-arm radiographs are commonly used for intraoperative image guidance in surgical interventions. Fluoroscopy is a cost-effective real-time modality, although image quality can vary greatly depending on the target anatomy. Cone-beam computed tomography (CBCT) scans are sometimes available, so 2D-3D registration is needed for intra-procedural guidance. C-arm radiographs were registered to CBCT scans and used for 3D localization of peritumor fiducials during a minimally invasive thoracic intervention with a da Vinci Si robot. Intensity-based 2D-3D registration of intraoperative radiographs to CBCT was performed. The feasible range of X-ray projections achievable by a C-arm positioned around a da Vinci Si surgical robot, configured for robotic wedge resection, was determined using phantom models. Experiments were conducted on synthetic phantoms and animals imaged with an OEC 9600 and a Siemens Artis zeego, representing the spectrum of different C-arm systems currently available for clinical use. The image guidance workflow was feasible using either an optically tracked OEC 9600 or a Siemens Artis zeego C-arm, resulting in an angular difference of Δθ:∼ 30°. The two C-arm systems provided TRE mean ≤ 2.5 mm and TRE mean ≤ 2.0 mm, respectively (i.e., comparable to standard clinical intraoperative navigation systems). C-arm 3D localization from dual 2D-3D registered radiographs was feasible and applicable for intraoperative image guidance during da Vinci robotic thoracic interventions using the proposed workflow. Tissue deformation and in vivo experiments are required before clinical evaluation of this system.

  10. Sistem Kontrol Robot Arm 5 DOF Berbasis Pengenalan Pola Suara Menggunakan Mel-Frequency Cepstrum Coefficients (MFCC dan Adaptive Neuro-Fuzzy Inference System (ANFIS

    Directory of Open Access Journals (Sweden)

    WS Mada Sanjaya

    2016-12-01

    Full Text Available Telah dilakukan penelitian yang menggambarkan implementasi pengenalan pola suara untuk mengontrol gerak robot arm 5 DoF dalam mengambil dan menyimpan benda. Dalam penelitian ini metode yang digunakan adalah Mel-Frequency Cepstrum Coefficients (MFCC dan Adaptive Neuro-Fuzzy Inferense System (ANFIS. Metode MFCC digunakan untuk ekstraksi ciri sinyal suara, sedangkan ANFIS digunakan sebagai metode pembelajaran untuk pengenalan pola suara. Pada proses pembelajaran ANFIS data latih yang digunakan sebanyak 6 ciri. Data suara terlatih dan data suara tak terlatih digunakan untuk pengujian sistem pengenalan pola suara. Hasil pengujian menunjukkan tingkat keberhasilan, untuk data suara terlatih sebesar 87,77% dan data tak terlatih sebesar 78,53%. Sistem pengenalan pola suara ini telah diaplikasikan dengan baik untuk mengerakan robot arm 5 DoF berbasis mikrokontroler Arduino. Have been implemented of sound pattern recognition to control 5 DoF of Arm Robot to pick and place an object. In this research used Mel-Frequency Cepstrum Coefficients (MFCC and Adaptive Neuro-Fuzzy Interferense System (ANFIS methods. MFCC method used for features extraction of sound signal, meanwhile ANFIS used to learn sound pattern recognition. On ANFIS method data learning use 6 features. Trained and not trained data used to examine the system of sound pattern identification. The result show the succesfull level, for trained data 87.77% and for not trained data 78.53%. Sound pattern identification system was appliedto controlled 5 DoF arm robot based Arduino microcontroller.

  11. Active Elastic Skins for Soft Robotics

    Data.gov (United States)

    National Aeronautics and Space Administration — The use of the word robotic implies a rigid, bulky, and complex device. However, a confluence of factors now makes it possible to shed this stereotype and build...

  12. Robot arm based flat panel CT-guided electromagnetic tracked spine interventions: phantom and animal model experiments

    International Nuclear Information System (INIS)

    Penzkofer, Tobias; Isfort, Peter; Bruners, Philipp; Mahnken, Andreas H.; Wiemann, Christian; Guenther, Rolf W.; Kyriakou, Yiannis; Kalender, Willi A.; Schmitz-Rode, Thomas

    2010-01-01

    To evaluate accuracy and procedure times of electromagnetic tracking (EMT) in a robotic arm mounted flat panel setting using phantom and animal cadaveric models. A robotic arm mounted flat panel (RMFP) was used in combination with EMT to perform anthropomorphic phantom (n = 90) and ex vivo pig based punctures (n = 120) of lumbar facet joints (FJ, n = 120) and intervertebral discs (IVD, n = 90). Procedure accuracies and times were assessed and evaluated. FJ punctures were carried out with a spatial accuracy of 0.8 ± 0.9 mm (phantom) and 0.6 ± 0.8 mm (ex vivo) respectively. While IVD punctures showed puncture deviations of 0.6 ± 1.2 mm (phantom) and 0.5 ± 0.6 mm (ex vivo), direct and angulated phantom based punctures had accuracies of 0.8 ± 0.9 mm and 1.0 ± 1.3 mm. Planning took longer for ex vivo IVD punctures compared to phantom model interventions (39.3 ± 17.3 s vs. 20.8 ± 5.0 s, p = 0.001) and for angulated vs. direct phantom FJ punctures (19.7 ± 5.1 s vs. 28.6 ± 7.8 s, p < 0.001). Puncture times were longer for ex vivo procedures when compared to phantom model procedures in both FJ (37.9 ± 9.0 s vs. 23.6 ± 7.2 s, p = 0.001) and IVD punctures (43.9 ± 16.1 s vs. 31.1 ± 6.4 s, p = 0.026). The combination of RMFP with EMT provides an accurate method of navigation for spinal interventions such as facet joint punctures and intervertebral disc punctures. (orig.)

  13. Robot arm based flat panel CT-guided electromagnetic tracked spine interventions: phantom and animal model experiments

    Energy Technology Data Exchange (ETDEWEB)

    Penzkofer, Tobias; Isfort, Peter; Bruners, Philipp; Mahnken, Andreas H. [RWTH Aachen University, Applied Medical Engineering, Helmholtz-Institute Aachen, Aachen (Germany); RWTH Aachen University, Department of Diagnostic Radiology, Aachen University Hospital, Aachen (Germany); Wiemann, Christian; Guenther, Rolf W. [RWTH Aachen University, Department of Diagnostic Radiology, Aachen University Hospital, Aachen (Germany); Kyriakou, Yiannis; Kalender, Willi A. [Friedrich-Alexander University of Erlangen-Nuremberg, Institute for Medical Physics, Erlangen (Germany); Schmitz-Rode, Thomas [RWTH Aachen University, Applied Medical Engineering, Helmholtz-Institute Aachen, Aachen (Germany)

    2010-11-15

    To evaluate accuracy and procedure times of electromagnetic tracking (EMT) in a robotic arm mounted flat panel setting using phantom and animal cadaveric models. A robotic arm mounted flat panel (RMFP) was used in combination with EMT to perform anthropomorphic phantom (n = 90) and ex vivo pig based punctures (n = 120) of lumbar facet joints (FJ, n = 120) and intervertebral discs (IVD, n = 90). Procedure accuracies and times were assessed and evaluated. FJ punctures were carried out with a spatial accuracy of 0.8 {+-} 0.9 mm (phantom) and 0.6 {+-} 0.8 mm (ex vivo) respectively. While IVD punctures showed puncture deviations of 0.6 {+-} 1.2 mm (phantom) and 0.5 {+-} 0.6 mm (ex vivo), direct and angulated phantom based punctures had accuracies of 0.8 {+-} 0.9 mm and 1.0 {+-} 1.3 mm. Planning took longer for ex vivo IVD punctures compared to phantom model interventions (39.3 {+-} 17.3 s vs. 20.8 {+-} 5.0 s, p = 0.001) and for angulated vs. direct phantom FJ punctures (19.7 {+-} 5.1 s vs. 28.6 {+-} 7.8 s, p < 0.001). Puncture times were longer for ex vivo procedures when compared to phantom model procedures in both FJ (37.9 {+-} 9.0 s vs. 23.6 {+-} 7.2 s, p = 0.001) and IVD punctures (43.9 {+-} 16.1 s vs. 31.1 {+-} 6.4 s, p = 0.026). The combination of RMFP with EMT provides an accurate method of navigation for spinal interventions such as facet joint punctures and intervertebral disc punctures. (orig.)

  14. Behaviour based Mobile Robot Navigation Technique using AI System: Experimental Investigation on Active Media Pioneer Robot

    Directory of Open Access Journals (Sweden)

    S. Parasuraman, V.Ganapathy

    2012-10-01

    Full Text Available A key issue in the research of an autonomous robot is the design and development of the navigation technique that enables the robot to navigate in a real world environment. In this research, the issues investigated and methodologies established include (a Designing of the individual behavior and behavior rule selection using Alpha level fuzzy logic system  (b Designing of the controller, which maps the sensors input to the motor output through model based Fuzzy Logic Inference System and (c Formulation of the decision-making process by using Alpha-level fuzzy logic system. The proposed method is applied to Active Media Pioneer Robot and the results are discussed and compared with most accepted methods. This approach provides a formal methodology for representing and implementing the human expert heuristic knowledge and perception-based action in mobile robot navigation. In this approach, the operational strategies of the human expert driver are transferred via fuzzy logic to the robot navigation in the form of a set of simple conditional statements composed of linguistic variables.Keywards: Mobile robot, behavior based control, fuzzy logic, alpha level fuzzy logic, obstacle avoidance behavior and goal seek behavior

  15. SU-E-J-114: Towards Integrated CT and Ultrasound Guided Radiation Therapy Using A Robotic Arm with Virtual Springs

    Energy Technology Data Exchange (ETDEWEB)

    Ding, K; Zhang, Y; Sen, H; Lediju Bell, M; Goldstein, S; Kazanzides, P; Iordachita, I; Wong, J [Johns Hopkins University, Baltimore, MD (United States)

    2014-06-01

    Purpose: Currently there is an urgent need in Radiation Therapy for noninvasive and nonionizing soft tissue target guidance such as localization before treatment and continuous monitoring during treatment. Ultrasound is a portable, low cost option that can be easily integrated with the LINAC room. We are developing a cooperatively controlled robot arm that has high intrafraction reproducibility with repositioning of the ultrasound probe. In this study, we introduce virtual springs (VS) to assist with interfraction probe repositioning and we compare the soft tissue deformation introduced by VS to the deformation that would exist without them. Methods: Three metal markers were surgically implanted in the kidney of one dog. The dog was anesthetized and immobilized supine in an alpha cradle. The reference ultrasound probe position and force to ideally visualize the kidney was defined by an experienced ultrasonographer using the Clarity ultrasound system and robot sensor. For each interfraction study, the dog was removed from the cradle and re-setup based on CBCT with bony anatomy alignment to mimic regular patient setup. The ultrasound probe was automatically returned to the reference position using the robot. To accommodate the soft tissue anatomy changes between each setup the operator used the VS feature to adjust the probe and obtain an ultrasound image that matched the reference image. CBCT images were acquired and each interfraction marker location was compared with the first interfraction Result. Results: Analysis of the marker positions revealed that the kidney was displaced by 18.8 ± 6.4 mm without VS and 19.9 ± 10.5 mm with VS. No statistically significant differences were found between two procedures. Conclusion: The VS feature is necessary to obtain matching ultrasound images, and they do not introduce further changes to the tissue deformation. Future work will focus on automatic VS based on ultrasound feedback. Supported in part by: NCI R01 CA161613

  16. SU-E-J-114: Towards Integrated CT and Ultrasound Guided Radiation Therapy Using A Robotic Arm with Virtual Springs

    International Nuclear Information System (INIS)

    Ding, K; Zhang, Y; Sen, H; Lediju Bell, M; Goldstein, S; Kazanzides, P; Iordachita, I; Wong, J

    2014-01-01

    Purpose: Currently there is an urgent need in Radiation Therapy for noninvasive and nonionizing soft tissue target guidance such as localization before treatment and continuous monitoring during treatment. Ultrasound is a portable, low cost option that can be easily integrated with the LINAC room. We are developing a cooperatively controlled robot arm that has high intrafraction reproducibility with repositioning of the ultrasound probe. In this study, we introduce virtual springs (VS) to assist with interfraction probe repositioning and we compare the soft tissue deformation introduced by VS to the deformation that would exist without them. Methods: Three metal markers were surgically implanted in the kidney of one dog. The dog was anesthetized and immobilized supine in an alpha cradle. The reference ultrasound probe position and force to ideally visualize the kidney was defined by an experienced ultrasonographer using the Clarity ultrasound system and robot sensor. For each interfraction study, the dog was removed from the cradle and re-setup based on CBCT with bony anatomy alignment to mimic regular patient setup. The ultrasound probe was automatically returned to the reference position using the robot. To accommodate the soft tissue anatomy changes between each setup the operator used the VS feature to adjust the probe and obtain an ultrasound image that matched the reference image. CBCT images were acquired and each interfraction marker location was compared with the first interfraction Result. Results: Analysis of the marker positions revealed that the kidney was displaced by 18.8 ± 6.4 mm without VS and 19.9 ± 10.5 mm with VS. No statistically significant differences were found between two procedures. Conclusion: The VS feature is necessary to obtain matching ultrasound images, and they do not introduce further changes to the tissue deformation. Future work will focus on automatic VS based on ultrasound feedback. Supported in part by: NCI R01 CA161613

  17. Remote Viewing End Effectors for Light Duty Utility Arm Robot (U)

    International Nuclear Information System (INIS)

    Heckendorn, F.M.; Robinson, C.W.; Haynes, H.B.; Anderosn, E.K.; Pardini, A.F.

    1996-01-01

    The Robotics Development Groups at the Savannah River Site (SRS) and at the Hanford site have developed remote video and photography systems for deployment in underground radioactive-waste storage tanks at the Department of Energy (DOE) sites as a part of the Office of Science and Technology (OST) program within DOE. Viewing and documenting the tank interiors and their associated annular spaces is an extremely valuable tool in characterizing their condition and contents and in controlling their remediation. Several specialized video/photography systems and robotic End Effectors have been fabricated that provide remote viewing and lighting. All are remotely deployable into and out of the tank, with all viewing functions remotely operated. Positioning all control components away from the facility prevents the potential for personnel exposure to radiation and contamination. Only the remote video systems are discussed in this paper

  18. Visually and force controlled opening and closing of doors by means of a mobile robot arm

    OpenAIRE

    Milighetti, G.; Hoffmann, E.; Fetzner, Angelika; Kuntze, Helge-Björn

    2012-01-01

    A multi-sensory discrete-continuous control concept has been developed to realize interactive basic skills for humanoid and mobile service robots. In the upper hierarchy level a discrete task control structure enables the flexible execution of primitive skill sequences. In the lower continuous level a suitable controller is chosen with control parameters adapted to the current primitive skill. The basic skill for the frequently occurring task of unlocking and opening a door by means of a mobi...

  19. Kinematics design and human motion transfer for a humanoid service robot arm

    CSIR Research Space (South Africa)

    Dube, C

    2009-11-01

    Full Text Available . Philadelphia: Saunders Col- lege Publishing, 1982. [2] Hamill, J. and Knutzen, K. M., Biomechanical Basis of Human Motion, Baltimore: Williams and Wilkins, 1995. [3] Lenarcˇicˇ, J. and Klopcˇar, N.,“Positional kinematics of hu- manoid arms,” Robotica, vol...

  20. Robust, fast and accurate vision-based localization of a cooperative target used for space robotic arm

    Science.gov (United States)

    Wen, Zhuoman; Wang, Yanjie; Luo, Jun; Kuijper, Arjan; Di, Nan; Jin, Minghe

    2017-07-01

    When a space robotic arm deploys a payload, usually the pose between the cooperative target fixed on the payload and the hand-eye camera installed on the arm is calculated in real-time. A high-precision robust visual cooperative target localization method is proposed. Combing a circle, a line and dots as markers, a target that guarantees high detection rates is designed. Given an image, single-pixel-width smooth edges are drawn by a novel linking method. Circles are then quickly extracted using isophotes curvature. Around each circle, a square boundary in a pre-calculated proportion to the circle radius is set. In the boundary, the target is identified if certain numbers of lines exist. Based on the circle, the lines, and the target foreground and background intensities, markers are localized. Finally, the target pose is calculated by the Point-3-Perspective algorithm. The algorithm processes 8 frames per second with the target distance ranging from 0.3m to 1.5 m. It generated high-precision poses of above 97.5% on over 100,000 images regardless of camera background, target pose, illumination and motion blur. At 0.3 m, the rotation and translation errors were less than 0.015° and 0.2 mm. The proposed algorithm is very suitable for real-time visual measurement that requires high precision in aerospace.

  1. Pyrotechnic robot - constructive design and command

    Directory of Open Access Journals (Sweden)

    Ionel A. Staretu

    2013-10-01

    Full Text Available Pyrotechnic robots are service robots used to reduce the time for intervention of pyrotechnic troops and to diminish the danger for the operators. Pyrotechnic robots are used to inspect dangerous areas or/and to remove and to distroy explosive or suspicious devices/objects. These robots can be used to make corridors through mined battle fields, for manipulation and neutralization of unexploded ammunition, for inspection of vehicles, trains, airplanes and buildings. For these robots, a good functional activity is determined with regard to work space dimensions,, robotic arm kinematics and gripper characteristics. The paper shows the structural, kinematic, static synthesis and analysis as well as the design and functional simulation of the robotic arm and the grippers attached on the pyrotechnic robot designed by the authors.

  2. Advanced real-time multi-display educational system (ARMES): An innovative real-time audiovisual mentoring tool for complex robotic surgery.

    Science.gov (United States)

    Lee, Joong Ho; Tanaka, Eiji; Woo, Yanghee; Ali, Güner; Son, Taeil; Kim, Hyoung-Il; Hyung, Woo Jin

    2017-12-01

    The recent scientific and technologic advances have profoundly affected the training of surgeons worldwide. We describe a novel intraoperative real-time training module, the Advanced Robotic Multi-display Educational System (ARMES). We created a real-time training module, which can provide a standardized step by step guidance to robotic distal subtotal gastrectomy with D2 lymphadenectomy procedures, ARMES. The short video clips of 20 key steps in the standardized procedure for robotic gastrectomy were created and integrated with TilePro™ software to delivery on da Vinci Surgical Systems (Intuitive Surgical, Sunnyvale, CA). We successfully performed the robotic distal subtotal gastrectomy with D2 lymphadenectomy for patient with gastric cancer employing this new teaching method without any transfer errors or system failures. Using this technique, the total operative time was 197 min and blood loss was 50 mL and there were no intra- or post-operative complications. Our innovative real-time mentoring module, ARMES, enables standardized, systematic guidance during surgical procedures. © 2017 Wiley Periodicals, Inc.

  3. Parametric motion control of robotic arms: A biologically based approach using neural networks

    Science.gov (United States)

    Bock, O.; D'Eleuterio, G. M. T.; Lipitkas, J.; Grodski, J. J.

    1993-01-01

    A neural network based system is presented which is able to generate point-to-point movements of robotic manipulators. The foundation of this approach is the use of prototypical control torque signals which are defined by a set of parameters. The parameter set is used for scaling and shaping of these prototypical torque signals to effect a desired outcome of the system. This approach is based on neurophysiological findings that the central nervous system stores generalized cognitive representations of movements called synergies, schemas, or motor programs. It has been proposed that these motor programs may be stored as torque-time functions in central pattern generators which can be scaled with appropriate time and magnitude parameters. The central pattern generators use these parameters to generate stereotypical torque-time profiles, which are then sent to the joint actuators. Hence, only a small number of parameters need to be determined for each point-to-point movement instead of the entire torque-time trajectory. This same principle is implemented for controlling the joint torques of robotic manipulators where a neural network is used to identify the relationship between the task requirements and the torque parameters. Movements are specified by the initial robot position in joint coordinates and the desired final end-effector position in Cartesian coordinates. This information is provided to the neural network which calculates six torque parameters for a two-link system. The prototypical torque profiles (one per joint) are then scaled by those parameters. After appropriate training of the network, our parametric control design allowed the reproduction of a trained set of movements with relatively high accuracy, and the production of previously untrained movements with comparable accuracy. We conclude that our approach was successful in discriminating between trained movements and in generalizing to untrained movements.

  4. Robotics and automation activities in South Africa

    CSIR Research Space (South Africa)

    Utete, S

    2013-09-01

    Full Text Available Second in the series of articles focusing on the state of robotics and automation in the BRICS countries: Brazil, Russia, India, China, and South Africa, this article provides an overview on South Africa written by researchers from the Council...

  5. Robust trajectory tracking control of a dual-arm space robot actuated by control moment gyroscopes

    Science.gov (United States)

    Jia, Yinghong; Misra, Arun K.

    2017-08-01

    It is a new design concept to employ control moment gyroscopes (CMGs) as reactionless actuators for space robots. Such actuation has several noticeable advantages such as weak dynamical coupling and low power consumption over traditional joint motor actuation. This paper presents a robust control law for a CMG-actuated space robot in presence of system uncertainties and closed-chain constraints. The control objective is to make the manipulation variables to track the desired trajectories, and reduce the possibility of CMG saturation simultaneously. A reduced-order dynamical equation in terms of independent motion variables is derived using Kane's equations. Desired trajectories of the independent motion variables are derived by minimum-norm trajectory planning algorithm, and an adaptive sliding mode controller with improved adaptation laws is proposed to drive the independent motion variables tracking the desired trajectories. Uniformly ultimate boundedness of the closed loop system is proven using Lyapunov method. The redundancy of the full-order actual control torques is utilized to generate a null torque vector which reduces the possibility of CMG angular momentum saturation while producing no effect on the reduced-order control input. Simulation results demonstrate the effectiveness of the proposed algorithms and the advantage of weak dynamical coupling of the CMG-actuated system.

  6. dSPACE real time implementation of fuzzy PID position controller for vertical rotating single link arm robot using four-quadrant BLDC drive

    Directory of Open Access Journals (Sweden)

    Manikandan Ramasamy

    2017-07-01

    Full Text Available Automation has been growing in recent years for the manufacturing industries to increase productivity. Multiple robotic arms are used to handle materials for lifting in flexible directions. The vertical rotation of a 360 degree single arm is considered in this research on a position servo drive with brushless DC motor. The load torque of an arm varies depending upon the angular displacement due to gravity, so it requires four-quadrant operation of the drive with a robust feedback controller. This paper deals with the design and performance comparison of a conventional PID feedback controller with a fuzzy-based PID controller and suggests the most suitable controller. The design was implemented in real time through the dSPACE DS1104 controller environment to verify the dynamic behaviors of the arm.

  7. Active robotic training improves locomotor function in a stroke survivor

    Directory of Open Access Journals (Sweden)

    Krishnan Chandramouli

    2012-08-01

    Full Text Available Abstract Background Clinical outcomes after robotic training are often not superior to conventional therapy. One key factor responsible for this is the use of control strategies that provide substantial guidance. This strategy not only leads to a reduction in volitional physical effort, but also interferes with motor relearning. Methods We tested the feasibility of a novel training approach (active robotic training using a powered gait orthosis (Lokomat in mitigating post-stroke gait impairments of a 52-year-old male stroke survivor. This gait training paradigm combined patient-cooperative robot-aided walking with a target-tracking task. The training lasted for 4-weeks (12 visits, 3 × per week. The subject’s neuromotor performance and recovery were evaluated using biomechanical, neuromuscular and clinical measures recorded at various time-points (pre-training, post-training, and 6-weeks after training. Results Active robotic training resulted in considerable increase in target-tracking accuracy and reduction in the kinematic variability of ankle trajectory during robot-aided treadmill walking. These improvements also transferred to overground walking as characterized by larger propulsive forces and more symmetric ground reaction forces (GRFs. Training also resulted in improvements in muscle coordination, which resembled patterns observed in healthy controls. These changes were accompanied by a reduction in motor cortical excitability (MCE of the vastus medialis, medial hamstrings, and gluteus medius muscles during treadmill walking. Importantly, active robotic training resulted in substantial improvements in several standard clinical and functional parameters. These improvements persisted during the follow-up evaluation at 6 weeks. Conclusions The results indicate that active robotic training appears to be a promising way of facilitating gait and physical function in moderately impaired stroke survivors.

  8. TU-FG-BRB-11: Design and Evaluation of a Robotic C-Arm CBCT System for Image-Guided Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hua, C; Yao, W; Farr, J; Merchant, T [St. Jude Children’s Research Hospital, Memphis, TN (United States); Kidani, T; Tomida, K; Ozawa, S; Nishimura, T; Fujusawa, T; Shinagawa, R [Hitachi, Ltd., Hitachi-shi, Ibaraki-ken (Japan)

    2016-06-15

    Purpose: To describe the design and performance of a ceiling-mounted robotic C-arm CBCT system for image-guided proton therapy. Methods: Uniquely different from traditional C-arm CBCT used in interventional radiology, the imaging system was designed to provide volumetric image guidance for patients treated on a 190-degree proton gantry system and a 6 degree-of-freedom (DOF) robotic patient positioner. The mounting of robotic arms to the ceiling rails, rather than gantry or nozzle, provides the flexibility in imaging locations (isocenter, iso+27cm in X, iso+100cm in Y) in the room and easier upgrade as technology advances. A kV X-ray tube and a 43×43cm flat panel imager were mounted to a rotating C-ring (87cm diameter), which is coupled to the C-arm concentrically. Both C-arm and the robotic arm remain stationary during imaging to maintain high position accuracy. Source-to-axis distance and source-to-imager distance are 100 and 150cm, respectively. A 14:1 focused anti-scatter grid and a bowtie filer are used for image acquisition. A unique automatic collimator device of 4 independent blades for adjusting field of view and reducing patient dose has also been developed. Results: Sub-millimeter position accuracy and repeatability of the robotic C-arm were measured with a laser tracker. High quality CBCT images for positioning can be acquired with a weighted CTDI of 3.6mGy (head in 200° full fan mode: 100kV, 20mA, 20ms, 10fps)-8.7 mGy (pelvis in 360° half fan mode: 125kV, 42mA, 20ms, 10fps). Image guidance accuracy achieved <1mm (3D vector) with automatic 3D-3D registration for anthropomorphic head and pelvis phantoms. Since November 2015, 22 proton therapy patients have undergone daily CBCT imaging for 6 DOF positioning. Conclusion: Decoupled from gantry and nozzle, this CBCT system provides a unique solution for volumetric image guidance with half/partial proton gantry systems. We demonstrated that daily CBCT can be integrated into proton therapy for pre

  9. TU-FG-BRB-11: Design and Evaluation of a Robotic C-Arm CBCT System for Image-Guided Proton Therapy

    International Nuclear Information System (INIS)

    Hua, C; Yao, W; Farr, J; Merchant, T; Kidani, T; Tomida, K; Ozawa, S; Nishimura, T; Fujusawa, T; Shinagawa, R

    2016-01-01

    Purpose: To describe the design and performance of a ceiling-mounted robotic C-arm CBCT system for image-guided proton therapy. Methods: Uniquely different from traditional C-arm CBCT used in interventional radiology, the imaging system was designed to provide volumetric image guidance for patients treated on a 190-degree proton gantry system and a 6 degree-of-freedom (DOF) robotic patient positioner. The mounting of robotic arms to the ceiling rails, rather than gantry or nozzle, provides the flexibility in imaging locations (isocenter, iso+27cm in X, iso+100cm in Y) in the room and easier upgrade as technology advances. A kV X-ray tube and a 43×43cm flat panel imager were mounted to a rotating C-ring (87cm diameter), which is coupled to the C-arm concentrically. Both C-arm and the robotic arm remain stationary during imaging to maintain high position accuracy. Source-to-axis distance and source-to-imager distance are 100 and 150cm, respectively. A 14:1 focused anti-scatter grid and a bowtie filer are used for image acquisition. A unique automatic collimator device of 4 independent blades for adjusting field of view and reducing patient dose has also been developed. Results: Sub-millimeter position accuracy and repeatability of the robotic C-arm were measured with a laser tracker. High quality CBCT images for positioning can be acquired with a weighted CTDI of 3.6mGy (head in 200° full fan mode: 100kV, 20mA, 20ms, 10fps)-8.7 mGy (pelvis in 360° half fan mode: 125kV, 42mA, 20ms, 10fps). Image guidance accuracy achieved <1mm (3D vector) with automatic 3D-3D registration for anthropomorphic head and pelvis phantoms. Since November 2015, 22 proton therapy patients have undergone daily CBCT imaging for 6 DOF positioning. Conclusion: Decoupled from gantry and nozzle, this CBCT system provides a unique solution for volumetric image guidance with half/partial proton gantry systems. We demonstrated that daily CBCT can be integrated into proton therapy for pre

  10. User requirements for assistance of the supporting hand in bimanual daily activities via a robotic glove for severely affected stroke patients

    NARCIS (Netherlands)

    Prange, Grada Berendina; Smulders, Laura Cornelia; Smulders, L.C.; van Wijngaarden, J.; Lijbers, G.J.; Nijenhuis, Sharon Maria; Veltink, Petrus H.; Buurke, Jaap; Stienen, Arno; Braun, D.; Yu, H.; Campolo, D.

    2015-01-01

    For independent functioning in activities of daily life (ADL), proper hand function is paramount. Many stroke patients have a reduced ability to grasp and handle objects, while they don't fully recover functional use of the arm and hand, even after extensive (robotic) training. These patients may

  11. Robots to assist daily activities: views of older adults with Alzheimer's disease and their caregivers.

    Science.gov (United States)

    Wang, Rosalie H; Sudhama, Aishwarya; Begum, Momotaz; Huq, Rajibul; Mihailidis, Alex

    2017-01-01

    Robots have the potential to both enable older adults with dementia to perform daily activities with greater independence, and provide support to caregivers. This study explored perspectives of older adults with Alzheimer's disease (AD) and their caregivers on robots that provide stepwise prompting to complete activities in the home. Ten dyads participated: Older adults with mild-to-moderate AD and difficulty completing activity steps, and their family caregivers. Older adults were prompted by a tele-operated robot to wash their hands in the bathroom and make a cup of tea in the kitchen. Caregivers observed interactions. Semi-structured interviews were conducted individually. Transcribed interviews were thematically analyzed. Three themes summarized responses to robot interactions: contemplating a future with assistive robots, considering opportunities with assistive robots, and reflecting on implications for social relationships. Older adults expressed opportunities for robots to help in daily activities, were open to the idea of robotic assistance, but did not want a robot. Caregivers identified numerous opportunities and were more open to robots. Several wanted a robot, if available. Positive consequences of robots in caregiving scenarios could include decreased frustration, stress, and relationship strain, and increased social interaction via the robot. A negative consequence could be decreased interaction with caregivers. Few studies have investigated in-depth perspectives of older adults with dementia and their caregivers following direct interaction with an assistive prompting robot. To fulfill the potential of robots, continued dialogue between users and developers, and consideration of robot design and caregiving relationship factors are necessary.

  12. A Mechanical Musculo-Skeletal System for a Human-Shaped Robot Arm

    Directory of Open Access Journals (Sweden)

    Koichi Koganezawa

    2014-06-01

    Full Text Available This paper presents a mechanical system with a similar configuration to a human musculo-skeletal system for use in anthropomorphic robots or as artificial limbs for disabled persons. First, a mechanical module called ANLES (Actuator with Non-Linear Elasticity System is introduced. There are two types of ANLES: the linear-type ANLES and rotary-type ANLES. They can be used as a voluntary muscle in a wide-range of musculo-skeletal structures in which at least double actuators work in an antagonistic setup via some elastic elements. Next, an application of the two types of ANLES to a two-degree-of-freedom (DOF manipulator that has a similar configuration to the human elbow joint is shown. The experimental results of the joint stiffness and joint angle control elucidate that the developed mechanism effectively regulates joint stiffness in the same way as a musculo-skeletal system.

  13. Robot arm based flat panel CT-guided electromagnetic tracked spine interventions: phantom and animal model experiments.

    Science.gov (United States)

    Penzkofer, Tobias; Isfort, Peter; Bruners, Philipp; Wiemann, Christian; Kyriakou, Yiannis; Kalender, Willi A; Günther, Rolf W; Schmitz-Rode, Thomas; Mahnken, Andreas H

    2010-11-01

    To evaluate accuracy and procedure times of electromagnetic tracking (EMT) in a robotic arm mounted flat panel setting using phantom and animal cadaveric models. A robotic arm mounted flat panel (RMFP) was used in combination with EMT to perform anthropomorphic phantom (n = 90) and ex vivo pig based punctures (n = 120) of lumbar facet joints (FJ, n = 120) and intervertebral discs (IVD, n = 90). Procedure accuracies and times were assessed and evaluated. FJ punctures were carried out with a spatial accuracy of 0.8 ± 0.9 mm (phantom) and 0.6 ± 0.8 mm (ex vivo) respectively. While IVD punctures showed puncture deviations of 0.6 ± 1.2 mm (phantom) and 0.5 ± 0.6 mm (ex vivo), direct and angulated phantom based punctures had accuracies of 0.8 ± 0.9 mm and 1.0 ± 1.3 mm. Planning took longer for ex vivo IVD punctures compared to phantom model interventions (39.3 ± 17.3 s vs. 20.8 ± 5.0 s, p = 0.001) and for angulated vs. direct phantom FJ punctures (19.7 ± 5.1 s vs. 28.6 ± 7.8 s, p < 0.001). Puncture times were longer for ex vivo procedures when compared to phantom model procedures in both FJ (37.9 ± 9.0 s vs. 23.6 ± 7.2 s, p = 0.001) and IVD punctures (43.9 ± 16.1 s vs. 31.1 ± 6.4 s, p = 0.026). The combination of RMFP with EMT provides an accurate method of navigation for spinal interventions such as facet joint punctures and intervertebral disc punctures.

  14. Robotics

    Energy Technology Data Exchange (ETDEWEB)

    Lorino, P; Altwegg, J M

    1985-05-01

    This article, which is aimed at the general reader, examines latest developments in, and the role of, modern robotics. The 7 main sections are sub-divided into 27 papers presented by 30 authors. The sections are as follows: 1) The role of robotics, 2) Robotics in the business world and what it can offer, 3) Study and development, 4) Utilisation, 5) Wages, 6) Conditions for success, and 7) Technological dynamics.

  15. Path Planning of Mobile Elastic Robotic Arms by Indirect Approach of Optimal Control

    Directory of Open Access Journals (Sweden)

    Moharam Habibnejad Korayem

    2011-03-01

    Full Text Available Finding optimal trajectory is critical in several applications of robot manipulators. This paper is applied the open-loop optimal control approach for generating the optimal trajectory of the flexible mobile manipulators in point-to-point motion. This method is based on the Pontryagin-s minimum principle that by providing a two-point boundary value problem is solved the problem. This problem is known to be complex in particular when combined motion of the base and manipulator, non-holonomic constraint of the base and highly non-linear and complicated dynamic equations as a result of flexible nature of links are taken into account. The study emphasizes on modeling of the complete optimal control problem by remaining all nonlinear state and costate variables as well as control constraints. In this method, designer can compromise between different objectives by considering the proper penalty matrices and it yields to choose the proper trajectory among the various paths. The effectiveness and capability of the proposed approach are demonstrated through simulation studies. Finally, to verify the proposed method, the simulation results obtained from the model are compared with the results of those available in the literature.

  16. Variable Thumb Moment Arm Modeling and Thumb-Tip Force Production of a Human-Like Robotic Hand.

    Science.gov (United States)

    Niehues, Taylor D; Deshpande, Ashish D

    2017-10-01

    The anatomically correct testbed (ACT) hand mechanically simulates the musculoskeletal structure of the fingers and thumb of the human hand. In this work, we analyze the muscle moment arms (MAs) and thumb-tip force vectors in the ACT thumb in order to compare the ACT thumb's mechanical structure to the human thumb. Motion data are used to determine joint angle-dependent MA models, and thumb-tip three-dimensional (3D) force vectors are experimentally analyzed when forces are applied to individual muscles. Results are presented for both a nominal ACT thumb model designed to match human MAs and an adjusted model that more closely replicates human-like thumb-tip forces. The results confirm that the ACT thumb is capable of faithfully representing human musculoskeletal structure and muscle functionality. Using the ACT hand as a physical simulation platform allows us to gain a better understanding of the underlying biomechanical and neuromuscular properties of the human hand to ultimately inform the design and control of robotic and prosthetic hands.

  17. Self-organization via active exploration in robotic applications

    Science.gov (United States)

    Ogmen, H.; Prakash, R. V.

    1992-01-01

    We describe a neural network based robotic system. Unlike traditional robotic systems, our approach focussed on non-stationary problems. We indicate that self-organization capability is necessary for any system to operate successfully in a non-stationary environment. We suggest that self-organization should be based on an active exploration process. We investigated neural architectures having novelty sensitivity, selective attention, reinforcement learning, habit formation, flexible criteria categorization properties and analyzed the resulting behavior (consisting of an intelligent initiation of exploration) by computer simulations. While various computer vision researchers acknowledged recently the importance of active processes (Swain and Stricker, 1991), the proposed approaches within the new framework still suffer from a lack of self-organization (Aloimonos and Bandyopadhyay, 1987; Bajcsy, 1988). A self-organizing, neural network based robot (MAVIN) has been recently proposed (Baloch and Waxman, 1991). This robot has the capability of position, size rotation invariant pattern categorization, recognition and pavlovian conditioning. Our robot does not have initially invariant processing properties. The reason for this is the emphasis we put on active exploration. We maintain the point of view that such invariant properties emerge from an internalization of exploratory sensory-motor activity. Rather than coding the equilibria of such mental capabilities, we are seeking to capture its dynamics to understand on the one hand how the emergence of such invariances is possible and on the other hand the dynamics that lead to these invariances. The second point is crucial for an adaptive robot to acquire new invariances in non-stationary environments, as demonstrated by the inverting glass experiments of Helmholtz. We will introduce Pavlovian conditioning circuits in our future work for the precise objective of achieving the generation, coordination, and internalization

  18. Novel robotic systems and future directions

    Directory of Open Access Journals (Sweden)

    Ki Don Chang

    2018-01-01

    Full Text Available Robot-assistance is increasingly used in surgical practice. We performed a nonsystematic literature review using PubMed/MEDLINE and Google for robotic surgical systems and compiled information on their current status. We also used this information to predict future about the direction of robotic systems based on various robotic systems currently being developed. Currently, various modifications are being made in the consoles, robotic arms, cameras, handles and instruments, and other specific functions (haptic feedback and eye tracking that make up the robotic surgery system. In addition, research for automated surgery is actively being carried out. The development of future robots will be directed to decrease the number of incisions and improve precision. With the advent of artificial intelligence, a more practical form of robotic surgery system can be introduced and will ultimately lead to the development of automated robotic surgery system.

  19. Physical human-robot interaction of an active pelvis orthosis: toward ergonomic assessment of wearable robots.

    Science.gov (United States)

    d'Elia, Nicolò; Vanetti, Federica; Cempini, Marco; Pasquini, Guido; Parri, Andrea; Rabuffetti, Marco; Ferrarin, Maurizio; Molino Lova, Raffaele; Vitiello, Nicola

    2017-04-14

    In human-centered robotics, exoskeletons are becoming relevant for addressing needs in the healthcare and industrial domains. Owing to their close interaction with the user, the safety and ergonomics of these systems are critical design features that require systematic evaluation methodologies. Proper transfer of mechanical power requires optimal tuning of the kinematic coupling between the robotic and anatomical joint rotation axes. We present the methods and results of an experimental evaluation of the physical interaction with an active pelvis orthosis (APO). This device was designed to effectively assist in hip flexion-extension during locomotion with a minimum impact on the physiological human kinematics, owing to a set of passive degrees of freedom for self-alignment of the human and robotic hip flexion-extension axes. Five healthy volunteers walked on a treadmill at different speeds without and with the APO under different levels of assistance. The user-APO physical interaction was evaluated in terms of: (i) the deviation of human lower-limb joint kinematics when wearing the APO with respect to the physiological behavior (i.e., without the APO); (ii) relative displacements between the APO orthotic shells and the corresponding body segments; and (iii) the discrepancy between the kinematics of the APO and the wearer's hip joints. The results show: (i) negligible interference of the APO in human kinematics under all the experimented conditions; (ii) small (i.e., ergonomics assessment of wearable robots.

  20. Participation in Armed Forces, National, and International Sports Activities

    Science.gov (United States)

    1987-03-09

    American Games , Olympic Games , and other authorized national and international sports competitions (to include qualifying and preparatory events) as long...concerning the participation of Armed Forces personnel in Armed Forces, national, and international sports competitions ; establishes a Senior Military Sports ...program is to ensure that the U.S. Armed Forces are appropriately represented in national and international sports competitions . 3. The purpose of this

  1. Control of articulated snake robot under dynamic active constraints.

    Science.gov (United States)

    Kwok, Ka-Wai; Vitiello, Valentina; Yang, Guang-Zhong

    2010-01-01

    Flexible, ergonomically enhanced surgical robots have important applications to transluminal endoscopic surgery, for which path-following and dynamic shape conformance are essential. In this paper, kinematic control of a snake robot for motion stabilisation under dynamic active constraints is addressed. The main objective is to enable the robot to track the visual target accurately and steadily on deforming tissue whilst conforming to pre-defined anatomical constraints. The motion tracking can also be augmented with manual control. By taking into account the physical limits in terms of maximum frequency response of the system (manifested as a delay between the input of the manipulator and the movement of the end-effector), we show the importance of visual-motor synchronisation for performing accurate smooth pursuit movements. Detailed user experiments are performed to demonstrate the practical value of the proposed control mechanism.

  2. Mission Activity Planning for Humans and Robots on the Moon

    Science.gov (United States)

    Weisbin, C.; Shelton, K.; Lincoln, W.; Elfes, A.; Smith, J.H.; Mrozinski, J.; Hua, H.; Adumitroaie, V.; Silberg, R.

    2008-01-01

    A series of studies is conducted to develop a systematic approach to optimizing, both in terms of the distribution and scheduling of tasks, scenarios in which astronauts and robots accomplish a group of activities on the Moon, given an objective function (OF) and specific resources and constraints. An automated planning tool is developed as a key element of this optimization system.

  3. Intelligent assistive robots recent advances in assistive robotics for everyday activities

    CERN Document Server

    Moreno, Juan; Kong, Kyoungchul; Amirat, Yacine

    2015-01-01

    This book deals with the growing challenges of using assistive robots in our everyday activities along with providing intelligent assistive services. The presented applications concern mainly healthcare and wellness such as helping elderly people, assisting dependent persons, habitat monitoring in smart environments, well-being, security, etc. These applications reveal also new challenges regarding control theory, mechanical design, mechatronics, portability, acceptability, scalability, security, etc.  

  4. 6 DOF articulated-arm robot and mobile platform: Dynamic modelling as Multibody System and its validation via Experimental Modal Analysis.

    Science.gov (United States)

    Toledo Fuentes, A.; Kipfmueller, M.; José Prieto, M. A.

    2017-10-01

    Mobile manipulators are becoming a key instrument to increase the flexibility in industrial processes. Some of their requirements include handling of objects with different weights and sizes and their “fast” transportation, without jeopardizing production workers and machines. The compensation of forces affecting the system dynamic is therefore needed to avoid unwanted oscillations and tilting by sudden accelerations and decelerations. One general solution may be the implementation of external positioning elements to active stabilize the system. To accomplish the approach, the dynamic behavior of a robotic arm and a mobile platform was investigated to develop the stabilization mechanism using multibody simulations. The methodology used was divided into two phases for each subsystem: their natural frequencies and modal shapes were obtained using experimental modal analyses. Then, based on these experimental results, multibody simulation models (MBS) were set up and its dynamical parameters adjusted. Their modal shapes together with their obtained natural frequencies allowed a quantitative and qualitative analysis. In summary, the MBS models were successfully validated with the real subsystems, with a maximal percentage error of 15%. These models will serve as the basis for future steps in the design of the external actuators and its control strategy using a co-simulation tool.

  5. Investigation of Fatigability during Repetitive Robot-Mediated Arm Training in People with Multiple Sclerosis.

    Directory of Open Access Journals (Sweden)

    Deborah Severijns

    Full Text Available People with multiple sclerosis (MS are encouraged to engage in exercise programs but an increased experience of fatigue may impede sustained participation in training sessions. A high number of movements is, however, needed for obtaining optimal improvements after rehabilitation.This cross-sectional study investigated whether people with MS show abnormal fatigability during a robot-mediated upper limb movement trial. Sixteen people with MS and sixteen healthy controls performed five times three minutes of repetitive shoulder anteflexion movements. Movement performance, maximal strength, subjective upper limb fatigue and surface electromyography (median frequency and root mean square of the amplitude of the electromyography (EMG signal of the anterior deltoid were recorded during or in-between these exercises. After fifteen minutes of rest, one extra movement bout was performed to investigate how rest influences performance.A fifteen minutes upper limb movement protocol increased the perceived upper limb fatigue and induced muscle fatigue, given a decline in maximal anteflexion strength and changes of both the amplitude and the median frequency of EMG the anterior deltoid. In contrast, performance during the 3 minutes of anteflexion movements did not decline. There was no relation between changes in subjective fatigue and the changes in the amplitude and the median frequency of the anterior deltoid muscle, however, there was a correlation between the changes in subjective fatigue and changes in strength in people with MS. People with MS with upper limb weakness report more fatigue due to the repetitive movements, than people with MS with normal upper limb strength, who are comparable to healthy controls. The weak group could, however, keep up performance during the 15 minutes of repetitive movements.Albeit a protocol of repetitive shoulder anteflexion movements did not elicit a performance decline, fatigue feelings clearly increased in both

  6. A three-arm (laparoscopic, hand-assisted, and robotic) matched-case analysis of intraoperative and postoperative outcomes in minimally invasive colorectal surgery.

    Science.gov (United States)

    Patel, Chirag B; Ragupathi, Madhu; Ramos-Valadez, Diego I; Haas, Eric M

    2011-02-01

    Robotic-assisted laparoscopic surgery is an emerging modality in the field of minimally invasive colorectal surgery. However, there is a dearth of data comparing outcomes with other minimally invasive techniques. We present a 3-arm (conventional, hand-assisted, and robotic) matched-case analysis of intraoperative and short-term outcomes in patients undergoing minimally invasive colorectal procedures. Between August 2008 and October 2009, 70 robotic cases of the rectum and rectosigmoid were performed. Thirty of these were organized into triplets with conventional and hand-assisted cases based on the following 6 matching criteria: 1) surgeon; 2) sex; 3) body mass index; 4) operative procedure; 5) pathology; and 6) history of neoadjuvant therapy in malignant cases. Demographics, intraoperative parameters, and postoperative outcomes were assessed. Pathological outcomes were analyzed in malignant cases. Data were stratified by postoperative diagnosis and operative procedure. There was no significant difference in intraoperative complications, estimated blood loss (126.1 ± 98.5 mL overall), or postoperative morbidity and mortality among the groups. Robotic technique required longer operative time compared with conventional laparoscopic (P hand-assisted (P robotic approach results in short-term outcomes comparable to conventional and hand-assisted laparoscopic approaches for benign and malignant diseases of the rectum and rectosigmoid. With 3-dimensional visualization, additional freedom of motion, and improved ergonomics, this enabling technology may play an important role when performing colorectal procedures involving the pelvic anatomy.

  7. A Preliminary Study Exploring the Use of Fictional Narrative in Robotics Activities

    Science.gov (United States)

    Williams, Douglas; Ma, Yuxin; Prejean, Louise

    2010-01-01

    Educational robotics activities are gaining in popularity. Though some research data suggest that educational robotics can be an effective approach in teaching mathematics, science, and engineering, research is needed to generate the best practices and strategies for designing these learning environments. Existing robotics activities typically do…

  8. Implantación de un Controlador para la Cinemática Inversa del Brazo Robot Mitsubishi RV-2AJ a través de una Tarjeta ARM y MatLab

    OpenAIRE

    Cajamarca Peñafiel, Jorge Andres; Portilla Vargas, Alexis David

    2016-01-01

    The project involves the design and construction of a controller for handling the inverse and forward kinematics of the robot Mitsubishi RV-2AJ arm, it is located in the laboratories of the Salesian University in order to create a direct communication through an external card ARM and MatLab software. This driver allows the user to manipulate the robot arm Mitsubishi RV-2AJ in two categories, by joints and coordinates, with a compact hardware and easy to use interface, the autonomy is given...

  9. Feasibility of four-arm robotic lobectomy as solo surgery in patients with clinical stage I lung cancer.

    Science.gov (United States)

    Park, Seong Yong; Suh, Jee Won; Narm, Kyoung Sik; Lee, Chang Young; Lee, Jin Gu; Paik, Hyo Chae; Chung, Kyoung Young; Kim, Dae Joon

    2017-06-01

    This study was performed to investigate the feasibility of four-arm robotic lobectomy (FARL) as a solo surgical technique in patients with non-small cell lung cancer (NSCLC). Early outcome and long-term survival of FARL were compared with those of video-assisted thoracoscopic lobectomy (VATL). Prospective enrollment of patients with clinical stage I NSCLC undergoing FARL or VATL (20 patients in each group) was planned. Interim analysis for early postoperative outcome was performed after the initial 10 cases in each group. The study was terminated early because of safety issues in the FARL group after enrollment of 12 FARL and 17 VATL patients from 2011 to 2012. There were no differences in clinical characteristics between groups. Lobectomy time and total operation time were significantly longer in the FARL group (P=0.003). There were three life-threatening events in the FARL group (2 bleedings, 1 bronchus tear) that necessitated thoracotomy conversion in 1 patient. There were no differences in other operative outcomes including pain score, complications, or length of hospital stay. Pathologic stage and number of dissected lymph nodes (LNs) were also comparable. During a follow-up of 48.9±9.5 months, recurrence was identified in 2 (16.7%) patients in FARL group and 3 (23.5%) in VATL group. Five-year overall survival (100% vs . 87.5%, P=0.386) and disease-free survival (82.5% vs . 75.6%, P=0.589) were comparable. FARL as solo surgery could not be recommended because of safety issues. It required a longer operation time and had no benefits over VATL in terms of early postoperative outcome or long-term survival.

  10. Robotic-Arm Assisted Total Knee Arthroplasty Demonstrated Greater Accuracy and Precision to Plan Compared with Manual Techniques.

    Science.gov (United States)

    Hampp, Emily L; Chughtai, Morad; Scholl, Laura Y; Sodhi, Nipun; Bhowmik-Stoker, Manoshi; Jacofsky, David J; Mont, Michael A

    2018-05-01

    This study determined if robotic-arm assisted total knee arthroplasty (RATKA) allows for more accurate and precise bone cuts and component position to plan compared with manual total knee arthroplasty (MTKA). Specifically, we assessed the following: (1) final bone cuts, (2) final component position, and (3) a potential learning curve for RATKA. On six cadaver specimens (12 knees), a MTKA and RATKA were performed on the left and right knees, respectively. Bone-cut and final-component positioning errors relative to preoperative plans were compared. Median errors and standard deviations (SDs) in the sagittal, coronal, and axial planes were compared. Median values of the absolute deviation from plan defined the accuracy to plan. SDs described the precision to plan. RATKA bone cuts were as or more accurate to plan based on nominal median values in 11 out of 12 measurements. RATKA bone cuts were more precise to plan in 8 out of 12 measurements ( p  ≤ 0.05). RATKA final component positions were as or more accurate to plan based on median values in five out of five measurements. RATKA final component positions were more precise to plan in four out of five measurements ( p  ≤ 0.05). Stacked error results from all cuts and implant positions for each specimen in procedural order showed that RATKA error was less than MTKA error. Although this study analyzed a small number of cadaver specimens, there were clear differences that separated these two groups. When compared with MTKA, RATKA demonstrated more accurate and precise bone cuts and implant positioning to plan. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  11. Reach and grasp by people with tetraplegia using a neurally controlled robotic arm

    OpenAIRE

    Hochberg, Leigh R.; Bacher, Daniel; Jarosiewicz, Beata; Masse, Nicolas Y.; Simeral, John D.; Vogel, Joern; Haddadin, Sami; Liu, Jie; Cash, Sydney S.; van der Smagt, Patrick; Donoghue, John P.

    2012-01-01

    Paralysis following spinal cord injury, brainstemstroke, amyotrophic lateral sclerosis and other disorders can disconnect the brain from the body, eliminating the ability to perform volitional movements. A neural interface system could restore mobility and independence for people with paralysis by translating neuronal activity directly into control signals for assistive devices. We have previously shown that people with long-standing tetraplegia can use a neural interface ...

  12. Balance Maintenance in High-Speed Motion of Humanoid Robot Arm-Based on the 6D Constraints of Momentum Change Rate

    Directory of Open Access Journals (Sweden)

    Da-song Zhang

    2014-01-01

    Full Text Available Based on the 6D constraints of momentum change rate (CMCR, this paper puts forward a real-time and full balance maintenance method for the humanoid robot during high-speed movement of its 7-DOF arm. First, the total momentum formula for the robot’s two arms is given and the momentum change rate is defined by the time derivative of the total momentum. The author also illustrates the idea of full balance maintenance and analyzes the physical meaning of 6D CMCR and its fundamental relation to full balance maintenance. Moreover, discretization and optimization solution of CMCR has been provided with the motion constraint of the auxiliary arm’s joint, and the solving algorithm is optimized. The simulation results have shown the validity and generality of the proposed method on the full balance maintenance in the 6 DOFs of the robot body under 6D CMCR. This method ensures 6D dynamics balance performance and increases abundant ZMP stability margin. The resulting motion of the auxiliary arm has large abundance in joint space, and the angular velocity and the angular acceleration of these joints lie within the predefined limits. The proposed algorithm also has good real-time performance.

  13. Embodied Computation: An Active-Learning Approach to Mobile Robotics Education

    Science.gov (United States)

    Riek, L. D.

    2013-01-01

    This paper describes a newly designed upper-level undergraduate and graduate course, Autonomous Mobile Robots. The course employs active, cooperative, problem-based learning and is grounded in the fundamental computational problems in mobile robotics defined by Dudek and Jenkin. Students receive a broad survey of robotics through lectures, weekly…

  14. Robotics

    Indian Academy of Sciences (India)

    netic induction to detect an object. The development of ... end effector, inclination of object, magnetic and electric fields, etc. The sensors described ... In the case of a robot, the various actuators and motors have to be modelled. The major ...

  15. Patterns of motor activity in the isolated nerve cord of the octopus arm.

    Science.gov (United States)

    Gutfreund, Yoram; Matzner, Henry; Flash, Tamar; Hochner, Binyamin

    2006-12-01

    The extremely flexible octopus arm provides a unique opportunity for studying movement control in a highly redundant motor system. We describe a novel preparation that allows analysis of the peripheral nervous system of the octopus arm and its interaction with the muscular and mechanosensory elements of the arm's intrinsic muscular system. First we examined the synaptic responses in muscle fibers to identify the motor pathways from the axial nerve cord of the arm to the surrounding musculature. We show that the motor axons project to the muscles via nerve roots originating laterally from the arm nerve cord. The motor field of each nerve is limited to the region where the nerve enters the arm musculature. The same roots also carry afferent mechanosensory information from the intrinsic muscle to the axial nerve cord. Next, we characterized the pattern of activity generated in the dorsal roots by electrically stimulating the axial nerve cord. The evoked activity, although far reaching and long lasting, cannot alone account for the arm extension movements generated by similar electrical stimulation. The mismatch between patterns of activity in the isolated cord and in an intact arm may stem from the involvement of mechanosensory feedback in natural arm extension.

  16. Imitation of gestures by robotic arms: a quality assessment approach; Imitacion de gestos por brazos roboticos: Una propuesta para evaluar su calidad

    Energy Technology Data Exchange (ETDEWEB)

    Nope-Rodriguez, S.; Loaiza-Correa, H.; Caicedo-Bravo, E.

    2010-07-01

    This article proposes quantitative evaluation metrics of imitation, suited for the imitation of four gestures performed by a robotic arm on a simulation environment; for each gesture, the metric relies on a group of simple geometric shapes. This approach broadens the concept of imitation; since common metrics just accumulate the error between the joints of the demonstrator and the imitator along their trajectories, in other words, check for the exact replica of the gesture performed by the demonstrator. The results of the proposed metric are compared with an evaluation survey. (Author) 11 refs.

  17. Imaging-guided thoracoscopic resection of a ground-glass opacity lesion in a hybrid operating room equipped with a robotic C-arm CT system.

    Science.gov (United States)

    Hsieh, Chen-Ping; Hsieh, Ming-Ju; Fang, Hsin-Yueh; Chao, Yin-Kai

    2017-05-01

    The intraoperative identification of small pulmonary nodules through video-assisted thoracoscopic surgery remains challenging. Although preoperative CT-guided nodule localization is commonly used to detect tumors during video-assisted thoracoscopic surgery (VATS), this approach carries inherent risks. We report the case of a patient with stage I lung cancer presenting as an area of ground-glass opacity (GGO) in the right upper pulmonary lobe. He successfully underwent a single-stage, CT-guided localization and removal of the pulmonary nodule within a hybrid operating room (OR) equipped with a robotic C-arm.

  18. Robotic training and kinematic analysis of arm and hand after incomplete spinal cord injury: a case study.

    Science.gov (United States)

    Kadivar, Z; Sullivan, J L; Eng, D P; Pehlivan, A U; O'Malley, M K; Yozbatiran, N; Francisco, G E

    2011-01-01

    Regaining upper extremity function is the primary concern of persons with tetraplegia caused by spinal cord injury (SCI). Robotic rehabilitation has been inadequately tested and underutilized in rehabilitation of the upper extremity in the SCI population. Given the acceptance of robotic training in stroke rehabilitation and SCI gait training, coupled with recent evidence that the spinal cord, like the brain, demonstrates plasticity that can be catalyzed by repetitive movement training such as that available with robotic devices, it is probable that robotic upper-extremity training of persons with SCI could be clinically beneficial. The primary goal of this pilot study was to test the feasibility of using a novel robotic device for the upper extremity (RiceWrist) and to evaluate robotic rehabilitation using the RiceWrist in a tetraplegic person with incomplete SCI. A 24-year-old male with incomplete SCI participated in 10 sessions of robot-assisted therapy involving intensive upper limb training. The subject successfully completed all training sessions and showed improvements in movement smoothness, as well as in the hand function. Results from this study provide valuable information for further developments of robotic devices for upper limb rehabilitation in persons with SCI. © 2011 IEEE

  19. A self-centering active probing technique for kinematic parameter identification and verification of articulated arm coordinate measuring machines

    International Nuclear Information System (INIS)

    Santolaria, J; Brau, A; Velázquez, J; Aguilar, J J

    2010-01-01

    A crucial task in the procedure of identifying the parameters of a kinematic model of an articulated arm coordinate measuring machine (AACMM) or robot arm is the process of capturing data. In this paper a capturing data method is analyzed using a self-centering active probe, which drastically reduces the capture time and the required number of positions of the gauge as compared to the usual standard and manufacturer methods. The mathematical models of the self-centering active probe and AACMM are explained, as well as the mathematical model that links the AACMM global reference system to the probe reference system. We present a self-calibration method that will allow us to determine a homogeneous transformation matrix that relates the probe's reference system to the AACMM last reference system from the probing of a single sphere. In addition, a comparison between a self-centering passive probe and self-centering active probe is carried out to show the advantages of the latter in the procedures of kinematic parameter identification and verification of the AACMM

  20. Robot Mechanisms

    CERN Document Server

    Lenarcic, Jadran; Stanišić, Michael M

    2013-01-01

    This book provides a comprehensive introduction to the area of robot mechanisms, primarily considering industrial manipulators and humanoid arms. The book is intended for both teaching and self-study. Emphasis is given to the fundamentals of kinematic analysis and the design of robot mechanisms. The coverage of topics is untypical. The focus is on robot kinematics. The book creates a balance between theoretical and practical aspects in the development and application of robot mechanisms, and includes the latest achievements and trends in robot science and technology.

  1. South African Private Security Contractors Active in Armed Conflicts ...

    African Journals Online (AJOL)

    Not only is this legislation completely unique, but it appears wholly at odds with international opinion. In this article we place private security contractors (PSCs) under the microscope of international law, exploring the role they play in armed conflicts, and the status afforded them by international humanitarian law (IHL).

  2. Posture manipulation for rescue activity via small traction robots

    International Nuclear Information System (INIS)

    Iwano, Yuki; Osuka, Koichi; Amano, Hisanori

    2006-01-01

    We discuss a conceptual design of rescue robots against nuclear-power plant accidents. We claim that the rescue robots in nuclear-power plants should have the following properties. (1) The size is small. (2) The structure is simple. (3) The number of the robots is large. This paper studies the rescue robots to rescue people in an area polluted with radioactive leakage in nuclear power institutions. In particular, we propose a rescue system which consists of a group of small mobile robots. First, small traction robots set the posture of the fainted victims to carry easily, and carry them to the safety space with the mobile robots for the stretcher composition. In this paper, we describe the produced small traction robots. And, we confirm that the robots can manipulate a 40 kg dummy doll's posture. We also examine the optimal number of robots from a perspective of working efficiency in the assumption spot. (author)

  3. Brain-Computer Interface-based robotic end effector system for wrist and hand rehabilitation: results of a three-armed randomized controlled trial for chronic stroke

    Directory of Open Access Journals (Sweden)

    Kai Keng eAng

    2014-07-01

    Full Text Available The objective of this study was to investigate the efficacy of an Electroencephalography (EEG-based Motor Imagery (MI Brain-Computer Interface (BCI coupled with a Haptic Knob (HK robot for arm rehabilitation in stroke patients. In this three-arm, single-blind, randomized controlled trial; 21 chronic hemiplegic stroke patients (Fugl-Meyer Motor Assessment (FMMA score 10-50, recruited after pre-screening for MI BCI ability, were randomly allocated to BCI-HK, HK or Standard Arm Therapy (SAT groups. All groups received 18 sessions of intervention over 6 weeks, 3 sessions per week, 90 minutes per session. The BCI-HK group received 1 hour of BCI coupled with HK intervention, and the HK group received 1 hour of HK intervention per session. Both BCI-HK and HK groups received 120 trials of robot-assisted hand grasping and knob manipulation followed by 30 minutes of therapist-assisted arm mobilization. The SAT group received 1.5 hours of therapist-assisted arm mobilization and forearm pronation-supination movements incorporating wrist control and grasp-release functions. In all, 14 males, 7 females, mean age 54.2 years, mean stroke duration 385.1 days, with baseline FMMA score 27.0 were recruited. The primary outcome measure was upper-extremity FMMA scores measured mid-intervention at week 3, end-intervention at week 6, and follow-up at weeks 12 and 24. Seven, 8 and 7 subjects underwent BCI-HK, HK and SAT interventions respectively. FMMA score improved in all groups, but no intergroup differences were found at any time points. Significantly larger motor gains were observed in the BCI-HK group compared to the SAT group at weeks 3, 12 and 24, but motor gains in the HK group did not differ from the SAT group at any time point. In conclusion, BCI-HK is effective, safe, and may have the potential for enhancing motor recovery in chronic stroke when combined with therapist-assisted arm mobilization.

  4. Brain-computer interface-based robotic end effector system for wrist and hand rehabilitation: results of a three-armed randomized controlled trial for chronic stroke.

    Science.gov (United States)

    Ang, Kai Keng; Guan, Cuntai; Phua, Kok Soon; Wang, Chuanchu; Zhou, Longjiang; Tang, Ka Yin; Ephraim Joseph, Gopal J; Kuah, Christopher Wee Keong; Chua, Karen Sui Geok

    2014-01-01

    The objective of this study was to investigate the efficacy of an Electroencephalography (EEG)-based Motor Imagery (MI) Brain-Computer Interface (BCI) coupled with a Haptic Knob (HK) robot for arm rehabilitation in stroke patients. In this three-arm, single-blind, randomized controlled trial; 21 chronic hemiplegic stroke patients (Fugl-Meyer Motor Assessment (FMMA) score 10-50), recruited after pre-screening for MI BCI ability, were randomly allocated to BCI-HK, HK or Standard Arm Therapy (SAT) groups. All groups received 18 sessions of intervention over 6 weeks, 3 sessions per week, 90 min per session. The BCI-HK group received 1 h of BCI coupled with HK intervention, and the HK group received 1 h of HK intervention per session. Both BCI-HK and HK groups received 120 trials of robot-assisted hand grasping and knob manipulation followed by 30 min of therapist-assisted arm mobilization. The SAT group received 1.5 h of therapist-assisted arm mobilization and forearm pronation-supination movements incorporating wrist control and grasp-release functions. In all, 14 males, 7 females, mean age 54.2 years, mean stroke duration 385.1 days, with baseline FMMA score 27.0 were recruited. The primary outcome measure was upper extremity FMMA scores measured mid-intervention at week 3, end-intervention at week 6, and follow-up at weeks 12 and 24. Seven, 8 and 7 subjects underwent BCI-HK, HK and SAT interventions respectively. FMMA score improved in all groups, but no intergroup differences were found at any time points. Significantly larger motor gains were observed in the BCI-HK group compared to the SAT group at weeks 3, 12, and 24, but motor gains in the HK group did not differ from the SAT group at any time point. In conclusion, BCI-HK is effective, safe, and may have the potential for enhancing motor recovery in chronic stroke when combined with therapist-assisted arm mobilization.

  5. Markovian robots: Minimal navigation strategies for active particles

    Science.gov (United States)

    Nava, Luis Gómez; Großmann, Robert; Peruani, Fernando

    2018-04-01

    We explore minimal navigation strategies for active particles in complex, dynamical, external fields, introducing a class of autonomous, self-propelled particles which we call Markovian robots (MR). These machines are equipped with a navigation control system (NCS) that triggers random changes in the direction of self-propulsion of the robots. The internal state of the NCS is described by a Boolean variable that adopts two values. The temporal dynamics of this Boolean variable is dictated by a closed Markov chain—ensuring the absence of fixed points in the dynamics—with transition rates that may depend exclusively on the instantaneous, local value of the external field. Importantly, the NCS does not store past measurements of this value in continuous, internal variables. We show that despite the strong constraints, it is possible to conceive closed Markov chain motifs that lead to nontrivial motility behaviors of the MR in one, two, and three dimensions. By analytically reducing the complexity of the NCS dynamics, we obtain an effective description of the long-time motility behavior of the MR that allows us to identify the minimum requirements in the design of NCS motifs and transition rates to perform complex navigation tasks such as adaptive gradient following, detection of minima or maxima, or selection of a desired value in a dynamical, external field. We put these ideas in practice by assembling a robot that operates by the proposed minimalistic NCS to evaluate the robustness of MR, providing a proof of concept that is possible to navigate through complex information landscapes with such a simple NCS whose internal state can be stored in one bit. These ideas may prove useful for the engineering of miniaturized robots.

  6. Towards a real-time interface between a biomimetic model of sensorimotor cortex and a robotic arm

    OpenAIRE

    Dura-Bernal, Salvador; Chadderdon, George L; Neymotin, Samuel A; Francis, Joseph T; Lytton, William W

    2014-01-01

    Brain-machine interfaces can greatly improve the performance of prosthetics. Utilizing biomimetic neuronal modeling in brain machine interfaces (BMI) offers the possibility of providing naturalistic motor-control algorithms for control of a robotic limb. This will allow finer control of a robot, while also giving us new tools to better understand the brain’s use of electrical signals. However, the biomimetic approach presents challenges in integrating technologies across multiple hardware and...

  7. Handling uncertainty and networked structure in robot control

    CERN Document Server

    Tamás, Levente

    2015-01-01

    This book focuses on two challenges posed in robot control by the increasing adoption of robots in the everyday human environment: uncertainty and networked communication. Part I of the book describes learning control to address environmental uncertainty. Part II discusses state estimation, active sensing, and complex scenario perception to tackle sensing uncertainty. Part III completes the book with control of networked robots and multi-robot teams. Each chapter features in-depth technical coverage and case studies highlighting the applicability of the techniques, with real robots or in simulation. Platforms include mobile ground, aerial, and underwater robots, as well as humanoid robots and robot arms. Source code and experimental data are available at http://extras.springer.com. The text gathers contributions from academic and industry experts, and offers a valuable resource for researchers or graduate students in robot control and perception. It also benefits researchers in related areas, such as computer...

  8. Shape-estimation of human hand using polymer flex sensor and study of its application to control robot arm

    International Nuclear Information System (INIS)

    Lee, Jin Hyuck; Kim, Dae Hyun

    2015-01-01

    Ultrasonic inspection robot systems have been widely researched and developed for the real-time monitoring of structures such as power plants. However, an inspection robot that is operated in a simple pattern has limitations in its application to various structures in a plant facility because of the diverse and complicated shapes of the inspection objects. Therefore, accurate control of the robot is required to inspect complicated objects with high-precision results. This paper presents the idea that the shape and movement information of an ultrasonic inspector's hand could be profitably utilized for the accurate control of robot. In this study, a polymer flex sensor was applied to monitor the shape of a human hand. This application was designed to intuitively control an ultrasonic inspection robot. The movement and shape of the hand were estimated by applying multiple sensors. Moreover, it was successfully shown that a test robot could be intuitively controlled based on the shape of a human hand estimated using polymer flex sensors.

  9. Shape-estimation of human hand using polymer flex sensor and study of its application to control robot arm

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Hyuck; Kim, Dae Hyun [Seoul National University of Technology, Seoul (Korea, Republic of)

    2015-02-15

    Ultrasonic inspection robot systems have been widely researched and developed for the real-time monitoring of structures such as power plants. However, an inspection robot that is operated in a simple pattern has limitations in its application to various structures in a plant facility because of the diverse and complicated shapes of the inspection objects. Therefore, accurate control of the robot is required to inspect complicated objects with high-precision results. This paper presents the idea that the shape and movement information of an ultrasonic inspector's hand could be profitably utilized for the accurate control of robot. In this study, a polymer flex sensor was applied to monitor the shape of a human hand. This application was designed to intuitively control an ultrasonic inspection robot. The movement and shape of the hand were estimated by applying multiple sensors. Moreover, it was successfully shown that a test robot could be intuitively controlled based on the shape of a human hand estimated using polymer flex sensors.

  10. Social Intelligence for a Robot Engaging People in Cognitive Training Activities

    Directory of Open Access Journals (Sweden)

    Jeanie Chan

    2012-10-01

    Full Text Available Current research supports the use of cognitive training interventions to improve the brain functioning of both adults and children. Our work focuses on exploring the potential use of robot assistants to allow for these interventions to become more accessible. Namely, we aim to develop an intelligent, socially assistive robot that can engage individuals in person-centred cognitively stimulating activities. In this paper, we present the design of a novel control architecture for the robot Brian 2.0, which enables the robot to be a social motivator by providing assistance, encouragement and celebration during an activity. A hierarchical reinforcement learning approach is used in the architecture to allow the robot to: 1 learn appropriate assistive behaviours based on the structure of the activity, and 2 personalize an interaction based on user states. Experiments show that the control architecture is effective in determining the robot's optimal assistive behaviours during a memory game interaction.

  11. Modeling and Control of Collaborative Robot System using Haptic Feedback

    Directory of Open Access Journals (Sweden)

    Vivekananda Shanmuganatha

    2017-08-01

    Full Text Available When two robot systems can share understanding using any agreed knowledge, within the constraints of the system’s communication protocol, the approach may lead to a common improvement. This has persuaded numerous new research inquiries in human-robot collaboration. We have built up a framework prepared to do independent following and performing table-best protest object manipulation with humans and we have actualized two different activity models to trigger robot activities. The idea here is to explore collaborative systems and to build up a plan for them to work in a collaborative environment which has many benefits to a single more complex system. In the paper, two robots that cooperate among themselves are constructed. The participation linking the two robotic arms, the torque required and parameters are analyzed. Thus the purpose of this paper is to demonstrate a modular robot system which can serve as a base on aspects of robotics in collaborative robots using haptics.

  12. Development of an instrumented and active servocontrolled robot gripper

    International Nuclear Information System (INIS)

    Debnath, S.K.; Dutta, A.K.; Deb, S.R.

    1990-01-01

    The design and construction of an instrumented and active robotic gripper is presented in this paper. The gripping device is a four-bar-linkage parallel jaw type end effector and the fingers are actuated by DC servo motor and gear drive. To make the gripper active, it is equipped with several sensors viz. straingauge type force sensor, magnetic proximity sensor, infrared sensor and vision sensor. A potentiometric position sensor is used to give position feed back of the fingers to the gripper controller. All sensory data are received by a Z-80 microprocessor and a software is developed to process data to transmit corresponding signals to the servocontroller designed for the gripper activation. The gripper can be used for automated grasping of randomly scattered object that remains in the field of view of the camera mounted on the gripper. (author). 3 refs., 2 figs

  13. Targeting and killing of glioblastoma with activated T cells armed with bispecific antibodies

    International Nuclear Information System (INIS)

    Zitron, Ian M; Thakur, Archana; Norkina, Oxana; Barger, Geoffrey R; Lum, Lawrence G; Mittal, Sandeep

    2013-01-01

    Since most glioblastomas express both wild-type EGFR and EGFRvIII as well as HER2/neu, they are excellent targets for activated T cells (ATC) armed with bispecific antibodies (BiAbs) that target EGFR and HER2. ATC were generated from PBMC activated for 14 days with anti-CD3 monoclonal antibody in the presence of interleukin-2 and armed with chemically heteroconjugated anti-CD3×anti-HER2/neu (HER2Bi) and/or anti-CD3×anti-EGFR (EGFRBi). HER2Bi- and/or EGFRBi-armed ATC were examined for in vitro cytotoxicity using MTT and 51 Cr-release assays against malignant glioma lines (U87MG, U118MG, and U251MG) and primary glioblastoma lines. EGFRBi-armed ATC killed up to 85% of U87, U118, and U251 targets at effector:target ratios (E:T) ranging from 1:1 to 25:1. Engagement of tumor by EGFRBi-armed ATC induced Th1 and Th2 cytokine secretion by armed ATC. HER2Bi-armed ATC exhibited comparable cytotoxicity against U118 and U251, but did not kill HER2-negative U87 cells. HER2Bi- or EGFRBi-armed ATC exhibited 50—80% cytotoxicity against four primary glioblastoma lines as well as a temozolomide (TMZ)-resistant variant of U251. Both CD133– and CD133+ subpopulations were killed by armed ATC. Targeting both HER2Bi and EGFRBi simultaneously showed enhanced efficacy than arming with a single BiAb. Armed ATC maintained effectiveness after irradiation and in the presence of TMZ at a therapeutic concentration and were capable of killing multiple targets. High-grade gliomas are suitable for specific targeting by armed ATC. These data, together with additional animal studies, may provide the preclinical support for the use of armed ATC as a valuable addition to current treatment regimens

  14. Teaching Joint-Level Robot Programming with a New Robotics Software Tool

    Directory of Open Access Journals (Sweden)

    Fernando Gonzalez

    2017-12-01

    Full Text Available With the rising popularity of robotics in our modern world there is an increase in the number of engineering programs that offer the basic Introduction to Robotics course. This common introductory robotics course generally covers the fundamental theory of robotics including robot kinematics, dynamics, differential movements, trajectory planning and basic computer vision algorithms commonly used in the field of robotics. Joint programming, the task of writing a program that directly controls the robot’s joint motors, is an activity that involves robot kinematics, dynamics, and trajectory planning. In this paper, we introduce a new educational robotics tool developed for teaching joint programming. The tool allows the student to write a program in a modified C language that controls the movement of the arm by controlling the velocity of each joint motor. This is a very important activity in the robotics course and leads the student to gain knowledge of how to build a robotic arm controller. Sample assignments are presented for different levels of difficulty.

  15. Robot-laser system

    International Nuclear Information System (INIS)

    Akeel, H.A.

    1987-01-01

    A robot-laser system is described for providing a laser beam at a desired location, the system comprising: a laser beam source; a robot including a plurality of movable parts including a hollow robot arm having a central axis along which the laser source directs the laser beam; at least one mirror for reflecting the laser beam from the source to the desired location, the mirror being mounted within the robot arm to move therewith and relative thereto to about a transverse axis that extends angularly to the central axis of the robot arm; and an automatic programmable control system for automatically moving the mirror about the transverse axis relative to and in synchronization with movement of the robot arm to thereby direct the laser beam to the desired location as the arm is moved

  16. Choice reaching with a LEGO arm robot (CoRLEGO): The motor system guides visual attention to movement-relevant information.

    Science.gov (United States)

    Strauss, Soeren; Woodgate, Philip J W; Sami, Saber A; Heinke, Dietmar

    2015-12-01

    We present an extension of a neurobiologically inspired robotics model, termed CoRLEGO (Choice reaching with a LEGO arm robot). CoRLEGO models experimental evidence from choice reaching tasks (CRT). In a CRT participants are asked to rapidly reach and touch an item presented on the screen. These experiments show that non-target items can divert the reaching movement away from the ideal trajectory to the target item. This is seen as evidence attentional selection of reaching targets can leak into the motor system. Using competitive target selection and topological representations of motor parameters (dynamic neural fields) CoRLEGO is able to mimic this leakage effect. Furthermore if the reaching target is determined by its colour oddity (i.e. a green square among red squares or vice versa), the reaching trajectories become straighter with repetitions of the target colour (colour streaks). This colour priming effect can also be modelled with CoRLEGO. The paper also presents an extension of CoRLEGO. This extension mimics findings that transcranial direct current stimulation (tDCS) over the motor cortex modulates the colour priming effect (Woodgate et al., 2015). The results with the new CoRLEGO suggest that feedback connections from the motor system to the brain's attentional system (parietal cortex) guide visual attention to extract movement-relevant information (i.e. colour) from visual stimuli. This paper adds to growing evidence that there is a close interaction between the motor system and the attention system. This evidence contradicts the traditional conceptualization of the motor system as the endpoint of a serial chain of processing stages. At the end of the paper we discuss CoRLEGO's predictions and also lessons for neurobiologically inspired robotics emerging from this work. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  17. User-centric design of a personal assistance robot (FRASIER) for active aging.

    Science.gov (United States)

    Padir, Taşkin; Skorinko, Jeanine; Dimitrov, Velin

    2015-01-01

    We present our preliminary results from the design process for developing the Worcester Polytechnic Institute's personal assistance robot, FRASIER, as an intelligent service robot for enabling active aging. The robot capabilities include vision-based object detection, tracking the user and help with carrying heavy items such as grocery bags or cafeteria trays. This work-in-progress report outlines our motivation and approach to developing the next generation of service robots for the elderly. Our main contribution in this paper is the development of a set of specifications based on the adopted user-centered design process, and realization of the prototype system designed to meet these specifications.

  18. An Evaluation of the Design and Usability of a Novel Robotic Bilateral Arm Rehabilitation Device for Patients with Stroke

    Directory of Open Access Journals (Sweden)

    Yu-Cheng Pei

    2017-07-01

    Full Text Available Study designCase series.Evidence levelIV (case series.IntroductionRobot-assisted therapy for upper limb rehabilitation is an emerging research topic and its design process must integrate engineering, neurological pathophysiology, and clinical needs.Purpose of the studyThis study developed/evaluated the usefulness of a novel rehabilitation device, the MirrorPath, designed for the upper limb rehabilitation of patients with hemiplegic stroke.MethodsThe process follows Tseng’s methodology for innovative product design and development, namely two stages, device development and usability assessment. During the development process, the design was guided by patients’ rehabilitation needs as defined by patients and their therapists. The design applied synchronic movement of the bilateral upper limbs, an approach that is compatible with the bilateral movement therapy and proprioceptive neuromuscular facilitation theories. MirrorPath consists of a robotic device that guides upper limb movement linked to a control module containing software controlling the robotic movement.ResultsFive healthy subjects were recruited in the pretest, and 4 patients, 4 caregivers, and 4 therapists were recruited in the formal test for usability. All recruited subjects were allocated to the test group, completed the evaluation, and their data were all analyzed. The total system usability scale score obtained from the patients, caregivers, and therapists was 71.8 ± 11.9, indicating a high level of usability and product acceptance.Discussion and conclusionFollowing a standard development process, we could yield a design that meets clinical needs. This low-cost device provides a feasible platform for carrying out robot-assisted bilateral movement therapy of patients with hemiplegic stroke.Clinical Trial Registrationidentifier NCT02698605.

  19. A Lower Limb Rehabilitation Robot in Sitting Position with a Review of Training Activities.

    Science.gov (United States)

    Eiammanussakul, Trinnachoke; Sangveraphunsiri, Viboon

    2018-01-01

    Robots for stroke rehabilitation at the lower limbs in sitting/lying position have been developed extensively. Some of them have been applied in clinics and shown the potential of the recovery of poststroke patients who suffer from hemiparesis. These robots were developed to provide training at different joints of lower limbs with various activities and modalities. This article reviews the training activities that were realized by rehabilitation robots in literature, in order to offer insights for developing a novel robot suitable for stroke rehabilitation. The control system of the lower limb rehabilitation robot in sitting position that was introduced in the previous work is discussed in detail to demonstrate the behavior of the robot while training a subject. The nonlinear impedance control law, based on active assistive control strategy, is able to define the response of the robot with more specifications while the passivity property and the robustness of the system is verified. A preliminary experiment is conducted on a healthy subject to show that the robot is able to perform active assistive exercises with various training activities and assist the subject to complete the training with desired level of assistance.

  20. A Lower Limb Rehabilitation Robot in Sitting Position with a Review of Training Activities

    Directory of Open Access Journals (Sweden)

    Trinnachoke Eiammanussakul

    2018-01-01

    Full Text Available Robots for stroke rehabilitation at the lower limbs in sitting/lying position have been developed extensively. Some of them have been applied in clinics and shown the potential of the recovery of poststroke patients who suffer from hemiparesis. These robots were developed to provide training at different joints of lower limbs with various activities and modalities. This article reviews the training activities that were realized by rehabilitation robots in literature, in order to offer insights for developing a novel robot suitable for stroke rehabilitation. The control system of the lower limb rehabilitation robot in sitting position that was introduced in the previous work is discussed in detail to demonstrate the behavior of the robot while training a subject. The nonlinear impedance control law, based on active assistive control strategy, is able to define the response of the robot with more specifications while the passivity property and the robustness of the system is verified. A preliminary experiment is conducted on a healthy subject to show that the robot is able to perform active assistive exercises with various training activities and assist the subject to complete the training with desired level of assistance.

  1. Active citizenship’ and feeding assistive robotics

    DEFF Research Database (Denmark)

    Nickelsen, Niels Christian Mossfeldt

    2018-01-01

    Would you want to be fed by a robot? This question may or may not sound attractive to a severely disabled citizen striving for self-reliance. Recently assistive robotics have become a new factor to rely on in relation to a number of aspects of social work and health care. These initiatives have...... study, I discuss the ways humans engage with them, how they co-produce everyday life in housing institutions, and the sensitivity of assistive robotics. During the latest years, Feeding Assistive Robotics (FAR) have enjoyed strong political endorsement in Denmark. Nevertheless, I argue, it is difficult...

  2. Using Haptic and Auditory Interaction Tools to Engage Students with Visual Impairments in Robot Programming Activities

    Science.gov (United States)

    Howard, A. M.; Park, Chung Hyuk; Remy, S.

    2012-01-01

    The robotics field represents the integration of multiple facets of computer science and engineering. Robotics-based activities have been shown to encourage K-12 students to consider careers in computing and have even been adopted as part of core computer-science curriculum at a number of universities. Unfortunately, for students with visual…

  3. Advances in Robotic Servicing Technology Development

    Science.gov (United States)

    Gefke, Gardell G.; Janas, Alex; Pellegrino, Joseph; Sammons, Matthew; Reed, Benjamin

    2015-01-01

    NASA's Satellite Servicing Capabilities Office (SSCO) has matured robotic and automation technologies applicable to in-space robotic servicing and robotic exploration over the last six years. This paper presents the progress of technology development activities at the Goddard Space Flight Center Servicing Technology Center and on the ISS, with an emphasis on those occurring in the past year. Highlighted advancements are design reference mission analysis for servicing in low Earth orbit (LEO) and asteroid redirection; delivery of the engineering development unit of the NASA Servicing Arm; an update on International Space Station Robotic Refueling Mission; and status of a comprehensive ground-based space robot technology demonstration expanding in-space robotic servicing capabilities beginning fall 2015.

  4. Dual Arm Work Module Development and Appplications

    Energy Technology Data Exchange (ETDEWEB)

    Noakes, M.W.

    1999-04-25

    The dual arm work module (DAWM) was developed at Oak Ridge National Laboratory (ORNL) by the Robotics Technology Development Program (RTDP) as a development test bed to study issues related to dual arm manipulation, including platform cotilguration, controls, automation, operations, and tooling. The original platform was based on two Schilling Titan II manipulators mounted to a 5-degree-of- freedom (DOF) base fabricated by RedZone Robotics, Inc. The 5-DOF articulation provided a center torso rotation, linear actuation to change the separation between the arms, and arm base rotation joints to provide "elbows up," elbows down," or "elbows out" orientation. A series of tests were conducted on operations, tooling, and task space scene analysis (TSSA)-driven robotics for overhead transporter- mounted and crane hook-deployed scenarios. A concept was developed for DAWM deployment from a large remote work vehicle, but the project was redirected to support dismantlement of the Chicago Pile #5 (CP-5) reactor at Argonne National Laboratory in fiscal year (FY) 1997. Support of CP-5 required a change in focus of the dual arm technology from that of a development test bed to a system focussed for a specific end user. ORNL teamed with the Idaho National Environmental ,Engineering Laboratory, Sandia National Laboratory, and the Savannah River Technology Center to deliver a crane-deployed derivative of the DAWM, designated the dual arm work platform (DAWP). RTDP staff supported DAWP at CP-5 for one FY; Argonne staff continued operation through to dismantlement of the reactor internals. Lessons learned from this interaction were extensive. Beginning in FY 1999, dual arm development activities are again being pursued in the context of those lessons learned. This paper describes the progression of philosophy of the DAWM from initial test bed to lessons learned through interaction at CP-5 and to the present investigation of telerobotic assist of teleoperation and TSSA- driven robotics.

  5. Influence of robotic shoal size, configuration, and activity on zebrafish behavior in a free-swimming environment.

    Science.gov (United States)

    Butail, Sachit; Polverino, Giovanni; Phamduy, Paul; Del Sette, Fausto; Porfiri, Maurizio

    2014-12-15

    In animal studies, robots have been recently used as a valid tool for testing a wide spectrum of hypotheses. These robots often exploit visual or auditory cues to modulate animal behavior. The propensity of zebrafish, a model organism in biological studies, toward fish with similar color patterns and shape has been leveraged to design biologically inspired robots that successfully attract zebrafish in preference tests. With an aim of extending the application of such robots to field studies, here, we investigate the response of zebrafish to multiple robotic fish swimming at different speeds and in varying arrangements. A soft real-time multi-target tracking and control system remotely steers the robots in circular trajectories during the experimental trials. Our findings indicate a complex behavioral response of zebrafish to biologically inspired robots. More robots produce a significant change in salient measures of stress, with a fast robot swimming alone causing more freezing and erratic activity than two robots swimming slowly together. In addition, fish spend more time in the proximity of a robot when they swim far apart than when the robots swim close to each other. Increase in the number of robots also significantly alters the degree of alignment of fish motion with a robot. Results from this study are expected to advance our understanding of robot perception by live animals and aid in hypothesis-driven studies in unconstrained free-swimming environments. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Aerial service robots: an overview of the AIRobots activity

    NARCIS (Netherlands)

    Marconi, L.; Naldi, R.; Torre, A.; Nikolic, J.; Huerzeler, C.; Caprari, G.; Zwicker, E.; Siciliano, B.; Lippiello, V.; Carloni, Raffaella; Stramigioli, Stefano

    This video paper outlines some of the results achieved during the first two years of the ongoing European project AIRobots (Innovative Aerial Service Robots for Remote Inspection by Contact, www.airobots.eu). Goal of AIRobots is to develop a new generation of aerial service robots capable of

  7. Development of the Strength Level on Arm for Indonesian People in Lifting Activity

    Science.gov (United States)

    Soewardi, H.; Prabaswari, A. D.; Muzakiroh, H. A.

    2017-12-01

    Lifting is one of manual material handling activity that involves the whole part of a body. This activity is significant to contribute musculoskeletal disorder specifically on arms. It is because the arms are a major strength to lift objects. However, many people do not know the capability of their arm so that the task designed does not comply with the limitation of workers. Thus, it is required to determine a level of strength on arms. The objective of this study is to develop the strength level of arms for Indonesian people based on musculoskeletal contraction. An experimental study is conducted in the ergonomics laboratory. 24 males and 24 females was participated in this study which consists of three different ethnics. They are sixteen participants of Ethnic A, sixteen participants of Ethnic B and sixteen participants of Ethnic C. A case study of lifting consists of 4 positions of object. They are 38 cm in height, 50 cm in height, 85 - 115 cm in height for forming 90 degrees of the elbow and 100 cm in height. Back lift technique was implemented. An Electromyography is used to investigate muscle contraction on arms. Statistical analysis is done to test the hypothesis. The result of this study shows that the arm strength level for Indonesian workers has significant differences between males and females among difference Ethnic. For male, Ethnic A has 28.82% - 79.28% of MVC, Ethnic B has 17.74% - 58.67% of MVC, and Ethnic C has 22.13% - 68.67% of MVC. For female, Ethnic A has 28.28% - 84.63% of MVC, Ethnic B has 24.47% - 70.98% of MVC, and Ethnic C has 24.24% - 75.67% of MVC.

  8. Approach for a smart device for active vibration suppression as an add-on for robot-based systems

    Energy Technology Data Exchange (ETDEWEB)

    Perner, Marcus; Krombholz, Christian; Monner, Hans Peter [Institute of Composite Structures and Adaptive Systems, Braunschweig (Germany)

    2014-11-15

    Robot-based systems are defined by the capabilities of links and joints that form the robot arm, the control including drive engines and the end effector. In particular, articulated robots have a serial structure. They have to carry the drive engine of each ongoing axis, which results in higher susceptibility to vibration. To compensate weak precision the German Aerospace Center (DLR) integrates a quality improving sensor system on the robot platform. A vibration monitoring system detects vibrations that affect the precision during motion tasks. Currently, higher precision is achieved by slowing down the speed in production. Therefore, a compromise is given between speed and precision. To push the limits for these two conflicting process properties, we propose an approach for an additional smart device to decouple the process-sensitive unit from disturbances arising through motion of the kinematic structure. The smart device enables active vibration suppression by use of a piezo-based actuator with a lever mechanism connected to a motion platform. The lever mechanism provides the required force and displacement adaption. The platform provides mounting and steering of the process-sensitive components. First, an insight into the automation task is given within this paper. Secondly, the system design is illustrated. Based on simulation results the characteristic of the proposed mechanism is shown. Besides the mechanical properties like stiffness and lever amplification, dynamical issues like the smallest eigenfrequency are discussed. To verify simulation results initial measurements are presented and discussed. The paper sums up with the discussion of an implementation of a closed-loop control system to achieve vibration-free and fast motion.

  9. Approach for a smart device for active vibration suppression as an add-on for robot-based systems

    International Nuclear Information System (INIS)

    Perner, Marcus; Krombholz, Christian; Monner, Hans Peter

    2014-01-01

    Robot-based systems are defined by the capabilities of links and joints that form the robot arm, the control including drive engines and the end effector. In particular, articulated robots have a serial structure. They have to carry the drive engine of each ongoing axis, which results in higher susceptibility to vibration. To compensate weak precision the German Aerospace Center (DLR) integrates a quality improving sensor system on the robot platform. A vibration monitoring system detects vibrations that affect the precision during motion tasks. Currently, higher precision is achieved by slowing down the speed in production. Therefore, a compromise is given between speed and precision. To push the limits for these two conflicting process properties, we propose an approach for an additional smart device to decouple the process-sensitive unit from disturbances arising through motion of the kinematic structure. The smart device enables active vibration suppression by use of a piezo-based actuator with a lever mechanism connected to a motion platform. The lever mechanism provides the required force and displacement adaption. The platform provides mounting and steering of the process-sensitive components. First, an insight into the automation task is given within this paper. Secondly, the system design is illustrated. Based on simulation results the characteristic of the proposed mechanism is shown. Besides the mechanical properties like stiffness and lever amplification, dynamical issues like the smallest eigenfrequency are discussed. To verify simulation results initial measurements are presented and discussed. The paper sums up with the discussion of an implementation of a closed-loop control system to achieve vibration-free and fast motion.

  10. Human-like Compliance for Dexterous Robot Hands

    Science.gov (United States)

    Jau, Bruno M.

    1995-01-01

    This paper describes the Active Electromechanical Compliance (AEC) system that was developed for the Jau-JPL anthropomorphic robot. The AEC system imitates the functionality of the human muscle's secondary function, which is to control the joint's stiffness: AEC is implemented through servo controlling the joint drive train's stiffness. The control strategy, controlling compliant joints in teleoperation, is described. It enables automatic hybrid position and force control through utilizing sensory feedback from joint and compliance sensors. This compliant control strategy is adaptable for autonomous robot control as well. Active compliance enables dual arm manipulations, human-like soft grasping by the robot hand, and opens the way to many new robotics applications.

  11. A long arm for ultrasound: a combined robotic focused ultrasound setup for magnetic resonance-guided focused ultrasound surgery.

    Science.gov (United States)

    Krafft, Axel J; Jenne, Jürgen W; Maier, Florian; Stafford, R Jason; Huber, Peter E; Semmler, Wolfhard; Bock, Michael

    2010-05-01

    Focused ultrasound surgery (FUS) is a highly precise noninvasive procedure to ablate pathogenic tissue. FUS therapy is often combined with magnetic resonance (MR) imaging as MR imaging offers excellent target identification and allows for continuous monitoring of FUS induced temperature changes. As the dimensions of the ultrasound (US) focus are typically much smaller than the targeted volume, multiple sonications and focus repositioning are interleaved to scan the focus over the target volume. Focal scanning can be achieved electronically by using phased-array US transducers or mechanically by using dedicated mechanical actuators. In this study, the authors propose and evaluate the precision of a combined robotic FUS setup to overcome some of the limitations of the existing MRgFUS systems. Such systems are typically integrated into the patient table of the MR scanner and thus only provide an application of the US wave within a limited spatial range from below the patient. The fully MR-compatible robotic assistance system InnoMotion (InnoMedic GmbH, Herxheim, Germany) was originally designed for MR-guided interventions with needles. It offers five pneumatically driven degrees of freedom and can be moved over a wide range within the bore of the magnet. In this work, the robotic system was combined with a fixed-focus US transducer (frequency: 1.7 MHz; focal length: 68 mm, and numerical aperture: 0.44) that was integrated into a dedicated, in-house developed treatment unit for FUS application. A series of MR-guided focal scanning procedures was performed in a polyacrylamide-egg white gel phantom to assess the positioning accuracy of the combined FUS setup. In animal experiments with a 3-month-old domestic pig, the system's potential and suitability for MRgFUS was tested. In phantom experiments, a total targeting precision of about 3 mm was found, which is comparable to that of the existing MRgFUS systems. Focus positioning could be performed within a few seconds

  12. Training the Unimpaired Arm Improves the Motion of the Impaired Arm and the Sitting Balance in Chronic Stroke Survivors.

    Science.gov (United States)

    De Luca, Alice; Giannoni, Psiche; Vernetti, Honore; Capra, Cristina; Lentino, Carmelo; Checchia, Giovanni Antonio; Casadio, Maura

    2017-07-01

    Robot-assisted rehabilitation of stroke survivors mainly focuses on the impaired side of the body while the role of the unimpaired side in the recovery after stroke is still controversial. The goal of this study is to investigate the influence on sitting balance and paretic arm functions of a training protocol based on movements of the unimpaired arm. Sixteen chronic stroke survivors underwent nineteen training sessions, in which they performed active movements with the unimpaired arm supported by a passive exoskeleton. Performance of the trunk and upper limbs was evaluated before treatment, after treatment and at six months follow up with clinical scales and an instrumented evaluation. A reaching test executed with the exoskeleton was used to assess changes in performance of both arms. The treatment based on the unimpaired arm's movements executed with a correct body posture led to benefits in control of the trunk and of both the trained and the untrained arm. The amount of impaired arm improvement in the Fugl-Meyer score was comparable to the outcome of robotic treatments focused directly on this arm. Our results highlight the importance of taking into account all body schema in the rehabilitation robotic program, instead of focusing only on the impaired side of the body.

  13. Sensory-Feedback Exoskeletal Arm Controller

    Science.gov (United States)

    An, Bin; Massie, Thomas H.; Vayner, Vladimir

    2004-01-01

    An electromechanical exoskeletal arm apparatus has been designed for use in controlling a remote robotic manipulator arm. The apparatus, called a force-feedback exoskeleton arm master (F-EAM) is comfortable to wear and easy to don and doff. It provides control signals from the wearer s arm to a robot arm or a computer simulator (e.g., a virtual-reality system); it also provides force and torque feedback from sensors on the robot arm or from the computer simulator to the wearer s arm. The F-EAM enables the wearer to make the robot arm gently touch objects and finely manipulate them without exerting excessive forces. The F-EAM features a lightweight design in which the motors and gear heads that generate force and torque feedback are made smaller than they ordinarily would be: this is achieved by driving the motors to power levels greater than would ordinarily be used in order to obtain higher torques, and by providing active liquid cooling of the motors to prevent overheating at the high drive levels. The F-EAM (see figure) includes an assembly that resembles a backpack and is worn like a backpack, plus an exoskeletal arm mechanism. The FEAM has five degrees of freedom (DOFs) that correspond to those of the human arm: 1. The first DOF is that of the side-to-side rotation of the upper arm about the shoulder (rotation about axis 1). The reflected torque for this DOF is provided by motor 1 via drum 1 and a planar four-bar linkage. 2. The second DOF is that of the up-and-down rotation of the arm about the shoulder. The reflected torque for this DOF is provided by motor 2 via drum 2. 3. The third DOF is that of twisting of the upper arm about its longitudinal axis. This DOF is implemented in a cable remote-center mechanism (CRCM). The reflected torque for this DOF is provided by motor 3, which drives the upper-arm cuff and the mechanism below it. A bladder inflatable by gas or liquid is placed between the cuff and the wearer s upper arm to compensate for misalignment

  14. Model-Based Design and Evaluation of a Brachiating Monkey Robot with an Active Waist

    Directory of Open Access Journals (Sweden)

    Alex Kai-Yuan Lo

    2017-09-01

    Full Text Available We report on the model-based development of a monkey robot that is capable of performing continuous brachiation locomotion on swingable rod, as the intermediate step toward studying brachiation on the soft rope or on horizontal ropes with both ends fixed. The work is different from other previous works where the model or the robot swings on fixed bars. The model, which is composed of two rigid links, was inspired by the dynamic motion of primates. The model further served as the design guideline for a robot that has five degree of freedoms: two on each arm for rod changing and one on the waist to initiate a swing motion. The model was quantitatively formulated, and its dynamic behavior was analyzed in simulation. Further, a two-stage controller was developed within the simulation environment, where the first stage used the natural dynamics of a two-link pendulum-like model, and the second stage used the angular velocity feedback to regulate the waist motion. Finally, the robot was empirically built and evaluated. The experimental results confirm that the robot can perform model-like swing behavior and continuous brachiation locomotion on rods.

  15. Mentoring console improves collaboration and teaching in surgical robotics.

    Science.gov (United States)

    Hanly, Eric J; Miller, Brian E; Kumar, Rajesh; Hasser, Christopher J; Coste-Maniere, Eve; Talamini, Mark A; Aurora, Alexander A; Schenkman, Noah S; Marohn, Michael R

    2006-10-01

    One of the most significant limitations of surgical robots has been their inability to allow multiple surgeons and surgeons-in-training to engage in collaborative control of robotic surgical instruments. We report the initial experience with a novel two-headed da Vinci surgical robot that has two collaborative modes: the "swap" mode allows two surgeons to simultaneously operate and actively swap control of the robot's four arms, and the "nudge" mode allows them to share control of two of the robot's arms. The utility of the mentoring console operating in its two collaborative modes was evaluated through a combination of dry laboratory exercises and animal laboratory surgery. The results from surgeon-resident collaborative performance of complex three-handed surgical tasks were compared to results from single-surgeon and single-resident performance. Statistical significance was determined using Student's t-test. Collaborative surgeon-resident swap control reduced the time to completion of complex three-handed surgical tasks by 25% compared to single-surgeon operation of a four-armed da Vinci (P nudge mode was particularly useful for guiding a resident's hands during crucially precise steps of an operation (such as proper placement of stitches). The da Vinci mentoring console greatly facilitates surgeon collaboration during robotic surgery and improves the performance of complex surgical tasks. The mentoring console has the potential to improve resident participation in surgical robotics cases, enhance resident education in surgical training programs engaged in surgical robotics, and improve patient safety during robotic surgery.

  16. Evaluation of the effects of the Arm Light Exoskeleton on movement execution and muscle activities: a pilot study on healthy subjects.

    Science.gov (United States)

    Pirondini, Elvira; Coscia, Martina; Marcheschi, Simone; Roas, Gianluca; Salsedo, Fabio; Frisoli, Antonio; Bergamasco, Massimo; Micera, Silvestro

    2016-01-23

    Exoskeletons for lower and upper extremities have been introduced in neurorehabilitation because they can guide the patient's limb following its anatomy, covering many degrees of freedom and most of its natural workspace, and allowing the control of the articular joints. The aims of this study were to evaluate the possible use of a novel exoskeleton, the Arm Light Exoskeleton (ALEx), for robot-aided neurorehabilitation and to investigate the effects of some rehabilitative strategies adopted in robot-assisted training. We studied movement execution and muscle activities of 16 upper limb muscles in six healthy subjects, focusing on end-effector and joint kinematics, muscle synergies, and spinal maps. The subjects performed three dimensional point-to-point reaching movements, without and with the exoskeleton in different assistive modalities and control strategies. The results showed that ALEx supported the upper limb in all modalities and control strategies: it reduced the muscular activity of the shoulder's abductors and it increased the activity of the elbow flexors. The different assistive modalities favored kinematics and muscle coordination similar to natural movements, but the muscle activity during the movements assisted by the exoskeleton was reduced with respect to the movements actively performed by the subjects. Moreover, natural trajectories recorded from the movements actively performed by the subjects seemed to promote an activity of muscles and spinal circuitries more similar to the natural one. The preliminary analysis on healthy subjects supported the use of ALEx for post-stroke upper limb robotic assisted rehabilitation, and it provided clues on the effects of different rehabilitative strategies on movement and muscle coordination.

  17. Inverse biomimetics: how robots can help to verify concepts concerning sensorimotor control of human arm and leg movements.

    Science.gov (United States)

    Kalveram, Karl Theodor; Seyfarth, André

    2009-01-01

    Simulation test, hardware test and behavioral comparison test are proposed to experimentally verify whether a technical control concept for limb movements is logically precise, physically sound, and biologically relevant. Thereby, robot test-beds may play an integral part by mimicking functional limb movements. The procedure is exemplarily demonstrated for human aiming movements with the forearm: when comparing competitive control concepts, these movements are described best by a spring-like operating muscular-skeletal device which is assisted by feedforward control through an inverse internal model of the limb--without regress to a forward model of the limb. In a perspective on hopping, the concept of exploitive control is addressed, and its comparison to concepts derived from classical control theory advised.

  18. When Should We Use Care Robots? The Nature-of-Activities Approach.

    Science.gov (United States)

    Santoni de Sio, Filippo; van Wynsberghe, Aimee

    2016-12-01

    When should we use care robots? In this paper we endorse the shift from a simple normative approach to care robots ethics to a complex one: we think that one main task of a care robot ethics is that of analysing the different ways in which different care robots may affect the different values at stake in different care practices. We start filling a gap in the literature by showing how the philosophical analysis of the nature of healthcare activities can contribute to (care) robot ethics. We rely on the nature-of-activities approach recently proposed in the debate on human enhancement, and we apply it to the ethics of care robots. The nature-of-activities approach will help us to understand why certain practice-oriented activities in healthcare should arguably be left to humans, but certain (predominantly) goal-directed activities in healthcare can be fulfilled (sometimes even more ethically) with the assistance of a robot. In relation to the latter, we aim to show that even though all healthcare activities can be considered as practice-oriented, when we understand the activity in terms of different legitimate 'fine-grained' descriptions, the same activities or at least certain components of them can be seen as clearly goal-directed. Insofar as it allows us to ethically assess specific functionalities of specific robots to be deployed in well-defined circumstances, we hold the nature-of-activities approach to be particularly helpful also from a design perspective, i.e. to realize the Value Sensitive Design approach.

  19. Enzymatic activities associated with arm regeneration and calcification in the starfish Asterias forbesi

    International Nuclear Information System (INIS)

    Donachy, J.E.

    1988-01-01

    The enzymes studied include Ka + , K + -ATPase, Ca 2+ -ATPase, Mg 2+ -ATPase, alkaline phosphatase and carbonic anhydrase. Each enzyme was examined for change in specific activity during salinity acclimation and arm regeneration. The effect of enzyme inhibition on 45 Ca deposition onto the calcified ossicles was examined and the enzymes were localized at the electron microscopic level. A. forbesi lacks a ouabain sensitive, Mg 2+ -dependent Ka + , K + -ATPase but possesses Mg 2+ -ATPase. Mg 2+ -ATPase was not affected by salinity and did not change during arm regeneration. A high affinity Ca 2+ -ATPase is also lacking in this starfish, but a low affinity form is present. Ca 2+ -ATPase is not involved in salinity acclimation of calcification, but may be involved in the would healing phase of arm regeneration. Alkaline phosphatase activity is not affected by salinity. Inhibition of this enzyme results in a significant increase in 45 Ca deposition onto the ossicles. During the early phase of arm regeneration, alkaline phosphatase activity increased significantly but gradually returned to control levels by 60 days post-autotomy

  20. Broken Arm

    Science.gov (United States)

    ... of falling — including football, soccer, gymnastics, skiing and skateboarding — also increases the risk of a broken arm. ... for high-risk activities, such as in-line skating, snowboarding, rugby and football. Don't smoke. Smoking ...

  1. Design and validation of low-cost assistive glove for hand assessment and therapy during activity of daily living-focused robotic stroke therapy.

    Science.gov (United States)

    Nathan, Dominic E; Johnson, Michelle J; McGuire, John R

    2009-01-01

    Hand and arm impairment is common after stroke. Robotic stroke therapy will be more effective if hand and upper-arm training is integrated to help users practice reaching and grasping tasks. This article presents the design, development, and validation of a low-cost, functional electrical stimulation grasp-assistive glove for use with task-oriented robotic stroke therapy. Our glove measures grasp aperture while a user completes simple-to-complex real-life activities, and when combined with an integrated functional electrical stimulator, it assists in hand opening and closing. A key function is a new grasp-aperture prediction model, which uses the position of the end-effectors of two planar robots to define the distance between the thumb and index finger. We validated the accuracy and repeatability of the glove and its capability to assist in grasping. Results from five nondisabled subjects indicated that the glove is accurate and repeatable for both static hand-open and -closed tasks when compared with goniometric measures and for dynamic reach-to-grasp tasks when compared with motion analysis measures. Results from five subjects with stroke showed that with the glove, they could open their hands but without it could not. We present a glove that is a low-cost solution for in vivo grasp measurement and assistance.

  2. Admittance-Based Upper Limb Robotic Active and Active-Assistive Movements

    Directory of Open Access Journals (Sweden)

    Cristóbal Ochoa Luna

    2015-09-01

    Full Text Available This paper presents two rehabilitation schemes for patients with upper limb impairments. The first is an active-assistive scheme based on the trajectory tracking of predefined paths in Cartesian space. In it, the system allows for an adjustable degree of variation with respect to ideal tracking. The amount of variation is determined through an admittance function that depends on the opposition forces exerted on the system by the user, due to possible impairments. The coefficients of the function allow the adjustment of the degree of assistance the robot will provide in order to complete the target trajectory. The second scheme corresponds to active movements in a constrained space. Here, the same admittance function is applied; however, in this case, it is unattached to a predefined trajectory and instead connected to one generated in real time, according to the user's intended movements. This allows the user to move freely with the robot in order to track a given path. The free movement is bounded through the use of virtual walls that do not allow users to exceed certain limits. A human-machine interface was developed to guide the robot's user.

  3. Towards Using a Generic Robot as Training Partner

    DEFF Research Database (Denmark)

    Sørensen, Anders Stengaard; Savarimuthu, Thiusius Rajeeth; Nielsen, Jacob

    2014-01-01

    In this paper, we demonstrate how a generic industrial robot can be used as a training partner, for upper limb training. The motion path and human/robot interaction of a non-generic upper-arm training robot is transferred to a generic industrial robot arm, and we demonstrate that the robot arm can...... implement the same type of interaction, but can expand the training regime to include both upper arm and shoulder training. We compare the generic robot to two affordable but custom-built training robots, and outline interesting directions for future work based on these training robots....

  4. Reverse engineering of the robot base platform

    International Nuclear Information System (INIS)

    Anwar A Rahman; Azizul Rahman A Aziz; Mohd Arif Hamzah; Muhd Nor Atan; Fadil Ismail; Rosli Darmawan

    2009-01-01

    The robot base platform used to place the robotic arm version 2 was imported through a local company. The robot base platform is used as a reference for reverse egineering development for a smaller size robot. The paper will discuss the reverse engineering design process and parameters involved in the development of the robot base platform. (Author)

  5. Incremental active learning of sensorimotor models in developmental robotics

    OpenAIRE

    Ribes Sanz, Arturo

    2015-01-01

    La rápida evolución de la robótica esta promoviendo que emerjan nuevos campos relacionados con la robótica. Inspirándose en ideas provinientes de la psicología del desarrollo, la robótica del desarrollo es un nuevo campo que pretende proveer a los robots de capacidades que les permiten aprender de una manera abierta durante toda su vida. Hay situaciones donde los ingenieros o los diseñadores no pueden prever todos los posibles problemas que un robot pueda encontrar. Tal como el número de tare...

  6. Robot-mediated ACtive REhabilitation (ACRE2) for the hemiplegic upper limb after a stroke: A pilot study

    NARCIS (Netherlands)

    Doornebosch, A.J.; Cools, H.J.M.; Slee-Turkenburg, M.E.C.; Elk, M.G. van; Schoone-Harmsen, M.

    2007-01-01

    Although scientific evidence shows that therapy improves movement recovery following a stroke, the duration of the reimbursed therapy available to patients is decreasing. To compensate for the reduction in personal therapy self-training procedures using robotic arms have been developed for

  7. Robot modelling; Control and applications with software

    Energy Technology Data Exchange (ETDEWEB)

    Ranky, P G; Ho, C Y

    1985-01-01

    This book provides a ''picture'' of robotics covering both the theoretical aspect of modeling as well as the practical and design aspects of: robot programming; robot tooling and automated hand changing; implementation planning; testing; and software design for robot systems. The authors present an introduction to robotics with a systems approach. They describe not only the tasks relating to a single robot (or arm) but also systems of robots working together on a product or several products.

  8. Robotics in Arthroplasty: A Comprehensive Review.

    Science.gov (United States)

    Jacofsky, David J; Allen, Mark

    2016-10-01

    Robotic-assisted orthopedic surgery has been available clinically in some form for over 2 decades, claiming to improve total joint arthroplasty by enhancing the surgeon's ability to reproduce alignment and therefore better restore normal kinematics. Various current systems include a robotic arm, robotic-guided cutting jigs, and robotic milling systems with a diversity of different navigation strategies using active, semiactive, or passive control systems. Semiactive systems have become dominant, providing a haptic window through which the surgeon is able to consistently prepare an arthroplasty based on preoperative planning. A review of previous designs and clinical studies demonstrate that these robotic systems decrease variability and increase precision, primarily focusing on component positioning and alignment. Some early clinical results indicate decreased revision rates and improved patient satisfaction with robotic-assisted arthroplasty. The future design objectives include precise planning and even further improved consistent intraoperative execution. Despite this cautious optimism, many still wonder whether robotics will ultimately increase cost and operative time without objectively improving outcomes. Over the long term, every industry that has seen robotic technology be introduced, ultimately has shown an increase in production capacity, improved accuracy and precision, and lower cost. A new generation of robotic systems is now being introduced into the arthroplasty arena, and early results with unicompartmental knee arthroplasty and total hip arthroplasty have demonstrated improved accuracy of placement, improved satisfaction, and reduced complications. Further studies are needed to confirm the cost effectiveness of these technologies. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Non-manufacturing applications of robotics

    International Nuclear Information System (INIS)

    Dauchez, P.

    2000-12-01

    This book presents the different non-manufacturing sectors of activity where robotics can have useful or necessary applications: underwater robotics, agriculture robotics, road work robotics, nuclear robotics, medical-surgery robotics, aids to disabled people, entertainment robotics. Service robotics has been voluntarily excluded because this developing sector is not mature yet. (J.S.)

  10. Domestic politics, citizen activism, and U.S. nuclear arms control policy

    International Nuclear Information System (INIS)

    Knopf, J.W.

    1991-01-01

    The author seeks to ascertain whether and how citizens' movements concerning nuclear arms control and disarmament affect US arms control policy. The author employs a comparative case study methodology. He examines cases of the Eisenhower and Kennedy Administrations during the period of protest against nuclear testing, and the Reagan Administration during the nuclear weapons freeze campaign and the subsequent campaign for a comprehensive test ban. He hows there are four mechanisms through which public advocacy efforts can influence arms control policy, identifies the conditions under which each can be effective, and details the type of impact each mechanism has. Domestic activism interacts with broader public opinion in a way that creates electoral pressure; with elite-level debates in a way that removes a consensus behind presidential policy or changes the winning coalition in Congress; with bureaucratic politics, by generating ideas that have utility for some agents within the Executive; or with the public diplomacy of foreign governments, especially the Soviet Union. Citizens' movements had an impact on policy in each of the cases studied. The type and extent of impact, and the mechanisms involved in giving activism influence, are different for each case

  11. Active Tension Control for WT Wheelchair Robot by Using a Novel Control Law for Holonomic or Nonholonomic Systems

    Directory of Open Access Journals (Sweden)

    Jian Wang

    2013-01-01

    Full Text Available Interactional characteristics between WT wheelchair robot and stair environment are analyzed, and possible patterns of WT wheelchair robot during the stair-climbing process are summarized, with the criteria of the wheelchair robot for determining the pattern proposed. Aiming at WT wheelchair robot's complicated mechanism with holonomic constraints and combined with the computed torque method, a novel control law that is called active tension control is presented for holonomic or nonholonomic robotic systems, by which the wheelchair robot with a holonomic or nonholonomic mechanism can track the reference input of the constraint forces of holonomic or nonholonomic constraints as well as tracking the reference input of the generalized coordinate of each joint. A stateflow module of Matlab is used to simulate the entire stair-climbing process for WT wheelchair robot. A comparison of output curve with the reference input curve of each joint is made, with the effectiveness of the presented control law verified.

  12. Effects of non-paretic arm exercises using a tubing band on abdominal muscle activity in stroke patients.

    Science.gov (United States)

    Lee, Dong-Kyu; Kang, Min-Hyeok; Kim, Ji-Won; Kim, Yang-Gon; Park, Ji-Hyuk; Oh, Jae-Seop

    2013-01-01

    Abdominal strengthening exercises are important for stroke patients; however, there is a lack of research on therapeutic exercises for increasing abdominal muscle activity in stroke patients. We investigated the effects of non-paretic arm exercises using a tubing band on abdominal muscle activity in stroke patients. In total, 18 hemiplegic subjects (13 males, 5 females) were recruited. All subjects performed non-paretic arm exercises involving three different shoulder movements (extension, flexion, and horizontal abduction) using an elastic tubing band. Surface electromyography (EMG) signals were recorded from the rectus abdominis (RA), external oblique (EO), and internal oblique (IO) muscles bilaterally during non-paretic arm exercises. EMG activities of abdominal muscles during non-paretic arm extension and horizontal abduction were increased significantly versus shoulder flexion when subjects performed the arm exercise in a seated position. Muscle activity of the EO was significantly greater in the paretic than the non-paretic side during non-paretic arm extension and horizontal abduction. We suggest that non-paretic arm extension and horizontal abduction exercises using an elastic tubing band may be effective in increasing abdominal muscle activity.

  13. MIDAS-FAST: Design and Validation of a Model-Based Tool to Predict Operator Performance with Robotic Arm Automation

    Science.gov (United States)

    Sebok, Angelia (Principal Investigator); Wickens, Christopher; Gacy, Marc; Brehon, Mark; Scott-Nash, Shelly; Sarter, Nadine; Li, Huiyang; Gore, Brian; Hooey, Becky

    2017-01-01

    The Coalition for Aerospace and Science (CAS) is hosting an exhibition on Capitol Hill on June 14, 2017, to highlight the contributions of CAS members to NASAs portfolio of activities. This exhibition represents an opportunity for an HFES members ground breaking work to be displayed and to build on support within Congress for NASAs human research program including in those areas that are of specific interest to the HFE community. The intent of this poster presentation is to demonstrate the positive outcome that comes from funding HFE related research on a project like the one exemplified by MIDAS-FAST.

  14. Efficient Active Sensing with Categorized Further Explorations for a Home Behavior-Monitoring Robot

    Directory of Open Access Journals (Sweden)

    Wenwei Yu

    2017-01-01

    Full Text Available Mobile robotics is a potential solution to home behavior monitoring for the elderly. For a mobile robot in the real world, there are several types of uncertainties for its perceptions, such as the ambiguity between a target object and the surrounding objects and occlusions by furniture. The problem could be more serious for a home behavior-monitoring system, which aims to accurately recognize the activity of a target person, in spite of these uncertainties. It detects irregularities and categorizes situations requiring further explorations, which strategically maximize the information needed for activity recognition while minimizing the costs. Two schemes of active sensing, based on two irregularity detections, namely, heuristic-based and template-matching-based irregularity detections, were implemented and examined for body contour-based activity recognition. Their time cost and accuracy in activity recognition were evaluated through experiments in both a controlled scenario and a home living scenario. Experiment results showed that the categorized further explorations guided the robot system to sense the target person actively. As a result, with the proposed approach, the robot system has achieved higher accuracy of activity recognition.

  15. Periodic activations of behaviours and emotional adaptation in behaviour-based robotics

    Science.gov (United States)

    Burattini, Ernesto; Rossi, Silvia

    2010-09-01

    The possible modulatory influence of motivations and emotions is of great interest in designing robotic adaptive systems. In this paper, an attempt is made to connect the concept of periodic behaviour activations to emotional modulation, in order to link the variability of behaviours to the circumstances in which they are activated. The impact of emotion is studied, described as timed controlled structures, on simple but conflicting reactive behaviours. Through this approach it is shown that the introduction of such asynchronies in the robot control system may lead to an adaptation in the emergent behaviour without having an explicit action selection mechanism. The emergent behaviours of a simple robot designed with both a parallel and a hierarchical architecture are evaluated and compared.

  16. Design and Control of JAIST Active Robotic Walker

    OpenAIRE

    Lee, Geunho; Ohnuma, Takanori; Chong, Nak Young

    2010-01-01

    This paper presents the design and control of a novel assistive robotic walker that we call “JAIST activerobotic walker (JARoW)”. JARoW is developed to providepotential users with sufficient ambulatory capability in anefficient、 cost-effective way. Specifically、 our focus is placed on how to allow easier maneuverability by creating a natural interface between the user and JARoW. For the purpose、 we develop a rotating infrared sensor to detect the user’s lower limb movement. The implementation...

  17. Self-Administered, Home-Based SMART (Sensorimotor Active Rehabilitation Training) Arm Training: A Single-Case Report.

    Science.gov (United States)

    Hayward, Kathryn S; Neibling, Bridee A; Barker, Ruth N

    2015-01-01

    This single-case, mixed-method study explored the feasibility of self-administered, home-based SMART (sensorimotor active rehabilitation training) Arm training for a 57-yr-old man with severe upper-limb disability after a right frontoparietal hemorrhagic stroke 9 mo earlier. Over 4 wk of self-administered, home-based SMART Arm training, the participant completed 2,100 repetitions unassisted. His wife provided support for equipment set-up and training progressions. Clinically meaningful improvements in arm impairment (strength), activity (arm and hand tasks), and participation (use of arm in everyday tasks) occurred after training (at 4 wk) and at follow-up (at 16 wk). Areas for refinement of SMART Arm training derived from thematic analysis of the participant's and researchers' journals focused on enabling independence, ensuring home and user friendliness, maintaining the motivation to persevere, progressing toward everyday tasks, and integrating practice into daily routine. These findings suggest that further investigation of self-administered, home-based SMART Arm training is warranted for people with stroke who have severe upper-limb disability. Copyright © 2015 by the American Occupational Therapy Association, Inc.

  18. Long-reach articulated robots for inspection and mini-invasive interventions in hazardous environments: Recent robotics research, qualification testing, and tool developments

    International Nuclear Information System (INIS)

    Perrot, Yann; Kammerer, Nolwenn; Measson, Yvan; Verney, Alexandre; Gargiulo, Laurent; Houry, Michael; Keller, Delphine; Piolain, Gerard

    2012-01-01

    The Interactive Robotics Laboratory of CEA LIST is in charge of the development of remote handling technologies to meet energy industry requirements. This paper reports the research and development activities in advanced robotics systems for inspection or light intervention in hazardous environments with limited access such as blind hot cells in the nuclear industry or the thermonuclear experimental Tokamak fusion reactor. A long-reach carrier robot called the articulated inspection arm (AIA) and diagnostics and tools for inspection or intervention are described. Finally experimental field tests are presented and actual challenges in modeling the robot's flexibilities are discussed. (authors)

  19. Access to hands-on mathematics measurement activities using robots controlled via speech generating devices: three case studies.

    Science.gov (United States)

    Adams, Kim; Cook, Al

    2014-07-01

    To examine how using a robot controlled via a speech generating device (SGD) influences the ways students with physical and communication limitations can demonstrate their knowledge in math measurement activities. Three children with severe physical disabilities and complex communication needs used the robot and SGD system to perform four math measurement lessons in comparing, sorting and ordering objects. The performance of the participants was measured and the process of using the system was described in terms of manipulation and communication events. Stakeholder opinions were solicited regarding robot use. Robot use revealed some gaps in the procedural knowledge of the participants. Access to both the robot and SGD was shown to provide several benefits. Stakeholders thought the intervention was important and feasible for a classroom environment. The participants were able to participate actively in the hands-on and communicative measurement activities and thus meet the demands of current math instruction methods. Current mathematics pedagogy encourages doing hands-on activities while communicating about concepts. Adapted Lego robots enabled children with severe physical disabilities to perform hands-on length measurement activities. Controlling the robots from speech generating devices (SGD) enabled the children, who also had complex communication needs, to reflect and report on results during the activities. By using the robots combined with SGDs, children both exhibited their knowledge of and experienced the concepts of mathematical measurements.

  20. Influence of complementing a robotic upper limb rehabilitation system with video games on the engagement of the participants: a study focusing on muscle activities.

    Science.gov (United States)

    Li, Chong; Rusák, Zoltán; Horváth, Imre; Ji, Linhong

    2014-12-01

    Efficacious stroke rehabilitation depends not only on patients' medical treatment but also on their motivation and engagement during rehabilitation exercises. Although traditional rehabilitation exercises are often mundane, technology-assisted upper-limb robotic training can provide engaging and task-oriented training in a natural environment. The factors that influence engagement, however, are not fully understood. This paper therefore studies the relationship between engagement and muscle activities as well as the influencing factors of engagement. To this end, an experiment was conducted using a robotic upper limb rehabilitation system with healthy individuals in three training exercises: (a) a traditional exercise, which is typically used for training the grasping function, (b) a tracking exercise, currently used in robot-assisted stroke patient rehabilitation for fine motor movement, and (c) a video game exercise, which is a proliferating approach of robot-assisted rehabilitation enabling high-level active engagement of stroke patients. These exercises differ not only in the characteristics of the motion that they use but also in their method of triggering engagement. To measure the level of engagement, we used facial expressions, motion analysis of the arm movements, and electromyography. The results show that (a) the video game exercise could engage the participants for a longer period than the other two exercises, (b) the engagement level decreased when the participants became too familiar with the exercises, and (c) analysis of normalized root mean square in electromyographic data indicated that muscle activities were more intense when the participants are engaged. This study shows that several sub-factors on engagement, such as versatility of feedback, cognitive tasks, and competitiveness, may influence engagement more than the others. To maintain a high level of engagement, the rehabilitation system needs to be adaptive, providing different exercises to

  1. A Modular, Reconfigurable Mold for a Soft Robotic Gripper Design Activity

    Directory of Open Access Journals (Sweden)

    Jiawei Zhang

    2017-09-01

    Full Text Available Soft robotics is an emerging field with strong potential to serve as an educational tool due to its advantages such as low costs and shallow learning curves. In this paper, we introduce a modular and reconfigurable mold for flexible design of pneumatic soft robotic grippers. By using simple assembly kits, students at all levels are able to design and construct soft robotic grippers that vary in function and performance. The process of constructing the modular mold enables students to understand how design choices impact system performance. Our unique modular mold allows students to select the number and length of fingers in a gripper, as well as to adjust the internal geometry of the pneumatic actuator cavity, which dictates how and where bending of a finger occurs. In addition, the mold may be deconstructed and reconfigured, which allows for fast iterative design and lowers material costs (since a new mold does not need to be made to implement a design change. We further demonstrate the feasibility of the modular mold by implementing it in a soft robot design activity in classrooms and showing a sufficiently high rate of student success in designing and constructing a functional soft robotic gripper.

  2. A new approach of active compliance control via fuzzy logic control for multifingered robot hand

    Science.gov (United States)

    Jamil, M. F. A.; Jalani, J.; Ahmad, A.

    2016-07-01

    Safety is a vital issue in Human-Robot Interaction (HRI). In order to guarantee safety in HRI, a model reference impedance control can be a very useful approach introducing a compliant control. In particular, this paper establishes a fuzzy logic compliance control (i.e. active compliance control) to reduce impact and forces during physical interaction between humans/objects and robots. Exploiting a virtual mass-spring-damper system allows us to determine a desired compliant level by understanding the behavior of the model reference impedance control. The performance of fuzzy logic compliant control is tested in simulation for a robotic hand known as the RED Hand. The results show that the fuzzy logic is a feasible control approach, particularly to control position and to provide compliant control. In addition, the fuzzy logic control allows us to simplify the controller design process (i.e. avoid complex computation) when dealing with nonlinearities and uncertainties.

  3. Active Learning Environments with Robotic Tangibles: Children's Physical and Virtual Spatial Programming Experiences

    Science.gov (United States)

    Burleson, Winslow S.; Harlow, Danielle B.; Nilsen, Katherine J.; Perlin, Ken; Freed, Natalie; Jensen, Camilla Nørgaard; Lahey, Byron; Lu, Patrick; Muldner, Kasia

    2018-01-01

    As computational thinking becomes increasingly important for children to learn, we must develop interfaces that leverage the ways that young children learn to provide opportunities for them to develop these skills. Active Learning Environments with Robotic Tangibles (ALERT) and Robopad, an analogous on-screen virtual spatial programming…

  4. The cortical activation pattern by a rehabilitation robotic hand: a functional NIRS study.

    Science.gov (United States)

    Chang, Pyung-Hun; Lee, Seung-Hee; Gu, Gwang Min; Lee, Seung-Hyun; Jin, Sang-Hyun; Yeo, Sang Seok; Seo, Jeong Pyo; Jang, Sung Ho

    2014-01-01

    Clarification of the relationship between external stimuli and brain response has been an important topic in neuroscience and brain rehabilitation. In the current study, using functional near infrared spectroscopy (fNIRS), we attempted to investigate cortical activation patterns generated during execution of a rehabilitation robotic hand. Ten normal subjects were recruited for this study. Passive movements of the right fingers were performed using a rehabilitation robotic hand at a frequency of 0.5 Hz. We measured values of oxy-hemoglobin (HbO), deoxy-hemoglobin (HbR) and total-hemoglobin (HbT) in five regions of interest: the primary sensory-motor cortex (SM1), hand somatotopy of the contralateral SM1, supplementary motor area (SMA), premotor cortex (PMC), and prefrontal cortex (PFC). HbO and HbT values indicated significant activation in the left SM1, left SMA, left PMC, and left PFC during execution of the rehabilitation robotic hand (uncorrected, p < 0.01). By contrast, HbR value indicated significant activation only in the hand somatotopic area of the left SM1 (uncorrected, p < 0.01). Our results appear to indicate that execution of the rehabilitation robotic hand could induce cortical activation.

  5. Child-Robot Interaction in the Wild : Field Testing Activities of the ALIZ-E Project

    NARCIS (Netherlands)

    Greeff, J. de; Blanson Henkemans, O.A.; Fraaije, A.; Solms, L.; Wigdor, N.; Bierman, B.

    2014-01-01

    A field study was conducted in which CRI activities developed by the ALIZ-E project were tested with the project's primary user group: children with diabetes. This field study resulted in new insights in the modalities and roles a robot aimed at CRI in a healthcare setting might utilise, while in

  6. Active vision via extremum seeking for robots in unstructured environments : Applications in object recognition and manipulation

    NARCIS (Netherlands)

    Calli, B.; Caarls, W.; Wisse, M.; Jonker, P.P.

    2018-01-01

    In this paper, a novel active vision strategy is proposed for optimizing the viewpoint of a robot's vision sensor for a given success criterion. The strategy is based on extremum seeking control (ESC), which introduces two main advantages: 1) Our approach is model free: It does not require an

  7. A soft wearable robot for the shoulder: Design, characterization, and preliminary testing.

    Science.gov (United States)

    O'Neill, Ciaran T; Phipps, Nathan S; Cappello, Leonardo; Paganoni, Sabrina; Walsh, Conor J

    2017-07-01

    In this paper, we present a soft wearable robot for the shoulder which has the potential to assist individuals suffering from a range of neuromuscular conditions affecting the shoulder to perform activities of daily living. This wearable robot combines two types of soft textile pneumatic actuators which were custom developed for this particular application to support the upper arm through shoulder abduction and horizontal flexion/extension. The advantage of a textile-based approach is that the robot can be lightweight, low-profile, comfortable and non-restrictive to the wearer, and easy to don like an item of clothing. The actuator's ability to fold flat when not in use allows the robot to be almost invisible under clothing, potentially allowing the user to avoid any stigma associated with using assistive devices in public. To abduct the arm, a textilebased pneumatic actuator was developed to fit within the axilla to push the arm upwards, while a pair of smaller actuators pivot the abduction actuator to allow for horizontal extension and flexion. The individual textile actuators were experimentally evaluated before being integrated into a wearable garment. Human subject testing was performed to evaluate the ability of the robot to assist the arm by monitoring changes in biological muscle activity when comparing the robot powered on and off. Preliminary results show large reductions in muscular effort in targeted muscles, demonstrating the feasibility and promise of such a soft wearable robot for the shoulder.

  8. Robots in the USA nuclear industry: An overview to the end of the 20th century

    International Nuclear Information System (INIS)

    Meleran, H.B.

    1993-01-01

    Stationary robotic arms, mobile robotic vehicles, ROV's and other underwater crawling robots, and pipecrawlers are beginning to play a growing role in nuclear power plants and other nuclear facilities. This paper presents an overview of the current status and availability of robots, and in particular mobile robots, in the nuclear industry in the US. Typical missions for the robots conducted upon terrestrial surfaces, underwater, inside pipelines, and above ground location will also be described. An additional focus will also be directed towards the examination of issues concerning evolving insights and new development projects which are currently underway. Successfully exploited technologies that have been developed for other non-nuclear activities the aerospace, underwater, and industrial environments are being incorporated into the new generation of robots used in the nuclear industry

  9. Active Bio-sensor System, Compatible with Arm Muscle Movement or Blinking Signals in BCI Application

    Directory of Open Access Journals (Sweden)

    Saeid Mehrkanoon

    2008-05-01

    Full Text Available This paper addresses a bionic active sensor system for the BCI application. Proposed system involves analog and digital parts. Two types of accurate sensors are used to pickup the blinking and muscle movement signals. A precision micro-power instrumentation amplifier with the adjustable gain, a sixth order low pass active filter with cutoff frequency 0.1 Hz, and a sixth order band pas filter with the bandwidth of 2-6 Hz are constructed to provide the clean blinking and arm muscle movement signals. TMS320C25 DSP processor is used for independent and unique command signals which are prepared for BCI application by a power amplifier and driver.

  10. The cortical activation pattern by a rehabilitation robotic hand : A functional NIRS study

    Directory of Open Access Journals (Sweden)

    Pyung Hun eChang

    2014-02-01

    Full Text Available Introduction: Clarification of the relationship between external stimuli and brain response has been an important topic in neuroscience and brain rehabilitation. In the current study, using functional near infrared spectroscopy (fNIRS, we attempted to investigate cortical activation patterns generated during execution of a rehabilitation robotic hand. Methods: Ten normal subjects were recruited for this study. Passive movements of the right fingers were performed using a rehabilitation robotic hand at a frequency of 0.5 Hz. We measured values of oxy-hemoglobin(HbO, deoxy-hemoglobin(HbR and total-hemoglobin(HbT in five regions of interest: the primary sensory-motor cortex (SM1, hand somatotopy of the contralateral SM1, supplementary motor area (SMA, premotor cortex (PMC, and prefrontal cortex (PFC. Results: HbO and HbT values indicated significant activation in the left SM1, left SMA, left PMC, and left PFC during execution of the rehabilitation robotic hand(uncorrected, pConclusions: Our results appear to indicate that execution of the rehabilitation robotic hand could induce cortical activation.

  11. Control of free-flying space robot manipulator systems

    Science.gov (United States)

    Cannon, Robert H., Jr.

    1989-01-01

    Control techniques for self-contained, autonomous free-flying space robots are being tested and developed. Free-flying space robots are envisioned as a key element of any successful long term presence in space. These robots must be capable of performing the assembly, maintenance, and inspection, and repair tasks that currently require astronaut extra-vehicular activity (EVA). Use of robots will provide economic savings as well as improved astronaut safety by reducing and in many cases, eliminating the need for human EVA. The focus of the work is to develop and carry out a set of research projects using laboratory models of satellite robots. These devices use air-cushion-vehicle (ACV) technology to simulate in two dimensions the drag-free, zero-g conditions of space. Current work is divided into six major projects or research areas. Fixed-base cooperative manipulation work represents our initial entry into multiple arm cooperation and high-level control with a sophisticated user interface. The floating-base cooperative manipulation project strives to transfer some of the technologies developed in the fixed-base work onto a floating base. The global control and navigation experiment seeks to demonstrate simultaneous control of the robot manipulators and the robot base position so that tasks can be accomplished while the base is undergoing a controlled motion. The multiple-vehicle cooperation project's goal is to demonstrate multiple free-floating robots working in teams to carry out tasks too difficult or complex for a single robot to perform. The Location Enhancement Arm Push-off (LEAP) activity's goal is to provide a viable alternative to expendable gas thrusters for vehicle propulsion wherein the robot uses its manipulators to throw itself from place to place. Because the successful execution of the LEAP technique requires an accurate model of the robot and payload mass properties, it was deemed an attractive testbed for adaptive control technology.

  12. Multi-robots to micro-surgery: Selected robotic applications at Sandia National Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, P.C. [Sandia National Labs., Albuquerque, NM (United States). Intelligent Systems and Robotics Center

    1996-11-01

    The Intelligent Systems and Robotics Center (ISRC) at Sandia National Laboratories is a multi-program organization, pursuing research, development and applications in a wide range of field. Activities range from large-scale applications such as nuclear facility dismantlement for the US Department of Energy (DOE), to aircraft inspection and refurbishment, to automated script and program generation for robotic manufacturing and assembly, to miniature robotic devices and sensors for remote sensing and micro-surgery. This paper describes six activities in the large and small scale that are underway and either nearing technology transfer stage or seeking industrial partners to continue application development. The topics of the applications include multiple arm coordination for intuitively maneuvering large, ungainly work pieces; simulation, analysis and graphical training capability for CP-5 research reactor dismantlement; miniature robots with volumes of 16 cubic centimeters and less developed for inspection and sensor deployment; and biomedical sensors to enhance automated prosthetic device production and fill laparoscopic surgery information gap.

  13. Which activities threaten independent living of elderly when becoming problematic: inspiration for meaningful service robot functionality.

    Science.gov (United States)

    Bedaf, Sandra; Gelderblom, Gert Jan; Syrdal, Dag Sverre; Lehmann, Hagen; Michel, Hervé; Hewson, David; Amirabdollahian, Farshid; Dautenhahn, Kerstin; de Witte, Luc

    2014-11-01

    In light of the increasing elderly population and the growing demand for home care, the potential of robot support is given increasing attention. In this paper, an inventory of activities was made that threaten independent living of elderly when becoming problematic. Results will guide the further development of an existing service robot, the Care-O-bot®. A systematic literature search of PubMed was performed, focused on the risk factors for institutionalization. Additionally, focus group sessions were conducted in the Netherlands, United Kingdom and France. In these focus group sessions, problematic activities threatening the independence of elderly people were discussed. Three separate target groups were included in the focus group sessions: (1) elderly persons (n = 41), (2) formal caregivers (n = 40) and (3) informal caregivers (n = 32). Activities within the International Classification of Functioning domains mobility, self-care, and interpersonal interaction and relationships were found to be the most problematic. A distinct set of daily activities was identified that may threaten independent living, but no single activity could be selected as the main activity causing a loss of independence as it is often a combination of problematic activities that is person-specific. Supporting the problematic activities need not involve a robotic solution.

  14. [Robot-aided training in rehabilitation].

    Science.gov (United States)

    Hachisuka, Kenji

    2010-02-01

    Recently, new training techniques that involve the use of robots have been used in the rehabilitation of patients with hemiplegia and paraplegia. Robots used for training the arm include the MIT-MANUS, Arm Trainer, mirror-image motion enabler (MIME) robot, and the assisted rehabilitation and measurement (ARM) Guide. Robots that are used for lower-limb training are the Rehabot, Gait Trainer, Lokomat, LOPES Exoskeleton Robot, and Gait Assist Robot. Robot-aided therapy has enabled the functional training of the arm and the lower limbs in an effective, easy, and comfortable manner. Therefore, with this type of therapy, the patients can repeatedly undergo sufficient and accurate training for a prolonged period. However, evidence of the benefits of robot-aided training has not yet been established.

  15. Timing of Multimodal Robot Behaviors during Human-Robot Collaboration

    DEFF Research Database (Denmark)

    Jensen, Lars Christian; Fischer, Kerstin; Suvei, Stefan-Daniel

    2017-01-01

    In this paper, we address issues of timing between robot behaviors in multimodal human-robot interaction. In particular, we study what effects sequential order and simultaneity of robot arm and body movement and verbal behavior have on the fluency of interactions. In a study with the Care-O-bot, ...... output plays a special role because participants carry their expectations from human verbal interaction into the interactions with robots....

  16. Biomechanical effects of robot assisted walking on knee joint kinematics and muscle activation pattern.

    Science.gov (United States)

    Thangavel, Pavithra; Vidhya, S; Li, Junhua; Chew, Effie; Bezerianos, Anastasios; Yu, Haoyong

    2017-07-01

    Since manual rehabilitation therapy can be taxing for both the patient and the physiotherapist, a gait rehabilitation robot has been built to reduce the physical strain and increase the efficacy of the rehabilitation therapy. The prototype of the gait rehabilitation robot is designed to provide assistance while walking for patients with abnormal gait pattern and it can also be used for rehabilitation therapy to restore an individual's normal gait pattern by aiding motor recovery. The Gait Rehabilitation Robot uses gait event based synchronization, which enables the exoskeleton to provide synchronous assistance during walking that aims to reduce the lower-limb muscle activation. This study emphasizes on the biomechanical effects of assisted walking on the lower limb by analyzing the EMG signal, knee joint kinematics data that was collected from the right leg during the various experimental conditions. The analysis of the measured data shows an improved knee joint trajectory and reduction in muscle activity with assistance. The result of this study does not only assess the functionality of the exoskeleton but also provides a profound understanding of the human-robot interaction by studying the effects of assistance on the lower limb.

  17. Reviews Book: The Babylonian Theorem Video Game: BrainBox360 (Physics Edition) Book: Teaching and Learning Science: Towards a Personalized Approach Book: Good Practice in Science Teaching: What Research Has to Say Equipment: PAPERSHOW Equipment: SEP Steady State Bottle Kit Equipment: Sciencescope Datalogging Balance Equipment: USB Robot Arm Equipment: Sciencescope Spectrophotometer Web Watch

    Science.gov (United States)

    2010-07-01

    WE RECOMMEND Good Practice in Science Teaching: What Research Has to Say Book explores and summarizes the research Steady State Bottle Kit Another gem from SEP Sciencescope Datalogging Balance Balance suits everyday use Sciencescope Spectrophotometer Device displays clear spectrum WORTH A LOOK The Babylonian Theorem Text explains ancient Egyptian mathematics BrainBox360 (Physics Edition) Video game tests your knowledge Teaching and Learning Science: Towards a Personalized Approach Book reveals how useful physics teachers really are PAPERSHOW Gadget kit is useful but has limitations Robotic Arm Kit with USB PC Interface Robot arm teaches programming WEB WATCH Simple applets teach complex topics

  18. 6-REXOS: Upper Limb Exoskeleton Robot with Improved pHRI

    Directory of Open Access Journals (Sweden)

    Malin Gunasekara

    2015-04-01

    Full Text Available Close interaction can be observed between an exoskeleton robot and its wearer. Therefore, appropriate physical human-robot interaction (pHRI should be considered when designing an exoskeleton robot to provide safe and comfortable motion assistance. Different features have been used in recent studies to enhance the pHRI in upper-limb exoskeleton robots. However, less attention has been given to integrating kinematic redundancy into upper-limb exoskeleton robots to improve the pHRI. In this context, this paper proposes a six-degrees-of-freedom (DoF upper-limb exoskeleton robot (6-REXOS for the motion assistance of physically weak individuals. The 6-REXOS uses a kinematically different structure to that of the human lower arm, where the exoskeleton robot is worn. The 6-REXOS has four active DoFs to generate the motion of the human lower arm. Furthermore, two flexible bellow couplings are attached to the wrist and elbow joints to generate two passive DoFs. These couplings not only allow translational motion in wrist and elbow joints but also a redundancy in the robot. Furthermore, the compliance of the flexible coupling contributes to avoiding misalignments between human and robot joint axes. The redundancy in the 6-REXOS is verified based on manipulability index, minimum singular value, condition number and manipulability ellipsoids. The 6-REXOS and a four-DoF exoskeleton robot are compared to verify the manipulation advantage due to the redundancy. The four-DoF exoskeleton robot is designed by excluding the two passive DoFs of the 6-REXOS. In addition, a kinematic model is proposed for the human lower arm to validate the performance of the 6-REXOS. Kinematic analysis and simulations are carried out to validate the 6-REXOS and human-lower-arm model.

  19. Controller design for Robotic hand through Electroencephalogram

    OpenAIRE

    Pandelidis P.; Kiriazis N.; Orgianelis K.; Koulios N.

    2016-01-01

    - This paper deals with the designing, the construction and the control of a robotic hand via an electroencephalogram sensor. First a robotic device that is able to mimic a real human hand is constructed. A PID controller is designed in order to improve the performance of the robotic arm for grabbing objects. Furthermore, a novel design approach is presented for controlling the motion of the robotic arm using signals produced from an innovative electroencephalogram sensor that detects the con...

  20. Development and Test of Robotically Assisted Extravehicular Activity Gloves

    Science.gov (United States)

    Rogers, Jonathan M.; Peters, Benjamin J.; Laske, Evan A.; McBryan, Emily R.

    2017-01-01

    Over the past two years, the High Performance EVA Glove (HPEG) project under NASA's Space Technology Mission Directorate (STMD) funded an effort to develop an electromechanically-assisted space suit glove. The project was a collaboration between the Johnson Space Center's Software, Robotics, and Simulation Division and the Crew and Thermal Systems division. The project sought to combine finger actuator technology developed for Robonaut 2 with the softgoods from the ILC Phase VI EVA glove. The Space Suit RoboGlove (SSRG) uses a system of three linear actuators to pull synthetic tendons attached to the glove's fingers to augment flexion of the user's fingers. To detect the user's inputs, the system utilizes a combination of string potentiometers along the back of the fingers and force sensitive resistors integrated into the fingertips of the glove cover layer. This paper discusses the development process from initial concepts through two major phases of prototypes, and the results of initial human testing. Initial work on the project focused on creating a functioning proof of concept, designing the softgoods integration, and demonstrating augmented grip strength with the actuators. The second year of the project focused on upgrading the actuators, sensors, and software with the overall goal of creating a system that moves with the user's fingers in order to reduce fatigue associated with the operation of a pressurized glove system. This paper also discusses considerations for a flight system based on this prototype development and address where further work is required to mature the technology.

  1. Comparison of POLDER Cloud Phase Retrievals to Active Remote Sensors Measurements at the ARM SGP Site

    International Nuclear Information System (INIS)

    Riedi, J.; Goloub, P.; Marchand, Roger T.

    2001-01-01

    In our present study, cloud boundaries derived from a combination of active remote sensors at the ARM SGP site are compared to POLDER cloud top phase index which is derived from polarimetric measurements using an innovative method. This approach shows the viability of the POLDER phase retrieval algorithm, and also leads to interesting results. In particular, the analysis demonstrates the sensitivity of polarization measurements to ice crystal shape and indicates that occurrence of polycrystalline ice clouds has to be taken into account in order to improve the POLDER phase retrieval algorithm accuracy. Secondly, the results show that a temperature threshold of 240 K could serve for cloud top particle phase classification. Considering the limitations of the analysis, the temperature threshold could be biased high, but not by more than about 5 degrees

  2. Applying a soft-robotic glove as assistive device and training tool with games to support hand function after stroke : Preliminary results on feasibility and potential clinical impact

    NARCIS (Netherlands)

    Prange, G.B.; Radder, Bob; Kottink, Anke I.R.; Melendez-Calderon, Alejandro; Buurke, Jaap H.; Rietman, Johan S.

    2017-01-01

    Recent technological developments regarding wearable soft-robotic devices extend beyond the current application of rehabilitation robotics and enable unobtrusive support of the arms and hands during daily activities. In this light, the HandinMind (HiM) system was developed, comprising a

  3. Multi-Robot Assembly Strategies and Metrics

    Science.gov (United States)

    MARVEL, JEREMY A.; BOSTELMAN, ROGER; FALCO, JOE

    2018-01-01

    We present a survey of multi-robot assembly applications and methods and describe trends and general insights into the multi-robot assembly problem for industrial applications. We focus on fixtureless assembly strategies featuring two or more robotic systems. Such robotic systems include industrial robot arms, dexterous robotic hands, and autonomous mobile platforms, such as automated guided vehicles. In this survey, we identify the types of assemblies that are enabled by utilizing multiple robots, the algorithms that synchronize the motions of the robots to complete the assembly operations, and the metrics used to assess the quality and performance of the assemblies. PMID:29497234

  4. Multi-Robot Assembly Strategies and Metrics.

    Science.gov (United States)

    Marvel, Jeremy A; Bostelman, Roger; Falco, Joe

    2018-02-01

    We present a survey of multi-robot assembly applications and methods and describe trends and general insights into the multi-robot assembly problem for industrial applications. We focus on fixtureless assembly strategies featuring two or more robotic systems. Such robotic systems include industrial robot arms, dexterous robotic hands, and autonomous mobile platforms, such as automated guided vehicles. In this survey, we identify the types of assemblies that are enabled by utilizing multiple robots, the algorithms that synchronize the motions of the robots to complete the assembly operations, and the metrics used to assess the quality and performance of the assemblies.

  5. System and method for controlling a vision guided robot assembly

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Yhu-Tin; Daro, Timothy; Abell, Jeffrey A.; Turner, III, Raymond D.; Casoli, Daniel J.

    2017-03-07

    A method includes the following steps: actuating a robotic arm to perform an action at a start position; moving the robotic arm from the start position toward a first position; determining from a vision process method if a first part from the first position will be ready to be subjected to a first action by the robotic arm once the robotic arm reaches the first position; commencing the execution of the visual processing method for determining the position deviation of the second part from the second position and the readiness of the second part to be subjected to a second action by the robotic arm once the robotic arm reaches the second position; and performing a first action on the first part using the robotic arm with the position deviation of the first part from the first position predetermined by the vision process method.

  6. Development of a 3D parallel mechanism robot arm with three vertical-axial pneumatic actuators combined with a stereo vision system.

    Science.gov (United States)

    Chiang, Mao-Hsiung; Lin, Hao-Ting

    2011-01-01

    This study aimed to develop a novel 3D parallel mechanism robot driven by three vertical-axial pneumatic actuators with a stereo vision system for path tracking control. The mechanical system and the control system are the primary novel parts for developing a 3D parallel mechanism robot. In the mechanical system, a 3D parallel mechanism robot contains three serial chains, a fixed base, a movable platform and a pneumatic servo system. The parallel mechanism are designed and analyzed first for realizing a 3D motion in the X-Y-Z coordinate system of the robot's end-effector. The inverse kinematics and the forward kinematics of the parallel mechanism robot are investigated by using the Denavit-Hartenberg notation (D-H notation) coordinate system. The pneumatic actuators in the three vertical motion axes are modeled. In the control system, the Fourier series-based adaptive sliding-mode controller with H(∞) tracking performance is used to design the path tracking controllers of the three vertical servo pneumatic actuators for realizing 3D path tracking control of the end-effector. Three optical linear scales are used to measure the position of the three pneumatic actuators. The 3D position of the end-effector is then calculated from the measuring position of the three pneumatic actuators by means of the kinematics. However, the calculated 3D position of the end-effector cannot consider the manufacturing and assembly tolerance of the joints and the parallel mechanism so that errors between the actual position and the calculated 3D position of the end-effector exist. In order to improve this situation, sensor collaboration is developed in this paper. A stereo vision system is used to collaborate with the three position sensors of the pneumatic actuators. The stereo vision system combining two CCD serves to measure the actual 3D position of the end-effector and calibrate the error between the actual and the calculated 3D position of the end-effector. Furthermore, to

  7. Bio-Inspired Control of an Arm Exoskeleton Joint with Active-Compliant Actuation System

    Directory of Open Access Journals (Sweden)

    Michele Folgheraiter

    2009-01-01

    Full Text Available This paper presents the methodology followed on the design of a multi-contact point haptic interface that uses a bio-inspired control approach and a novel actuation system. The combination of these components aims at creating a system that increases the operability of the target, and, at the same time, enables an intuitive and safe tele-operation of any complex robotic system of any given morphology. The novelty lies on the combination of a thoughtful kinematic structure driven by an active-compliant actuation system and a bio-inspired paradigm for its regulation. Due to the proposed actuation approach, the final system will achieve the condition of wearable system. On that final solution, each joint will be able to change its stiffness depending on the task to be executed, and on the anatomical features of each individual. Moreover, the system provides a variety of safety mechanisms at different levels to prevent causing any harm to the operator. In future, the system should allow the complete virtual immersion of the user within the working scenario.

  8. Design and Development of a Hand Exoskeleton Robot for Active and Passive Rehabilitation

    Directory of Open Access Journals (Sweden)

    Oscar Sandoval-Gonzalez

    2016-04-01

    Full Text Available The present work, which describes the mechatronic design and development of a novel rehabilitation robotic exoskeleton hand, aims to present a solution for neuromusculoskeletal rehabilitation. It presents a full range of motion for all hand phalanges and was specifically designed to carry out position and force-position control for passive and active rehabilitation routines. System integration and preliminary clinical tests are also presented.

  9. Sequencing bilateral robot-assisted arm therapy and constraint-induced therapy improves reach to press and trunk kinematics in patients with stroke.

    Science.gov (United States)

    Hsieh, Yu-wei; Liing, Rong-jiuan; Lin, Keh-chung; Wu, Ching-yi; Liou, Tsan-hon; Lin, Jui-chi; Hung, Jen-wen

    2016-03-22

    The combination of robot-assisted therapy (RT) and a modified form of constraint-induced therapy (mCIT) shows promise for improving motor function of patients with stroke. However, whether the changes of motor control strategies are concomitant with the improvements in motor function after combination of RT and mCIT (RT + mCIT) is unclear. This study investigated the effects of the sequential combination of RT + mCIT compared with RT alone on the strategies of motor control measured by kinematic analysis and on motor function and daily performance measured by clinical scales. The study enrolled 34 patients with chronic stroke. The data were derived from part of a single-blinded randomized controlled trial. Participants in the RT + mCIT and RT groups received 20 therapy sessions (90 to 105 min/day, 5 days for 4 weeks). Patients in the RT + mCIT group received 10 RT sessions for first 2 weeks and 10 mCIT sessions for the next 2 weeks. The Bi-Manu-Track was used in RT sessions to provide bilateral practice of wrist and forearm movements. The primary outcome was kinematic variables in a task of reaching to press a desk bell. Secondary outcomes included scores on the Wolf Motor Function Test, Functional Independence Measure, and Nottingham Extended Activities of Daily Living. All outcome measures were administered before and after intervention. RT + mCIT and RT demonstrated different benefits on motor control strategies. RT + mCIT uniquely improved motor control strategies by reducing shoulder abduction, increasing elbow extension, and decreasing trunk compensatory movement during the reaching task. Motor function and quality of the affected limb was improved, and patients achieved greater independence in instrumental activities of daily living. Force generation at movement initiation was improved in the patients who received RT. A combination of RT and mCIT could be an effective approach to improve stroke rehabilitation outcomes, achieving

  10. Innovation in robotic surgery: the Indian scenario.

    Science.gov (United States)

    Deshpande, Suresh V

    2015-01-01

    Robotics is the science. In scientific words a "Robot" is an electromechanical arm device with a computer interface, a combination of electrical, mechanical, and computer engineering. It is a mechanical arm that performs tasks in Industries, space exploration, and science. One such idea was to make an automated arm - A robot - In laparoscopy to control the telescope-camera unit electromechanically and then with a computer interface using voice control. It took us 5 long years from 2004 to bring it to the level of obtaining a patent. That was the birth of the Swarup Robotic Arm (SWARM) which is the first and the only Indian contribution in the field of robotics in laparoscopy as a total voice controlled camera holding robotic arm developed without any support by industry or research institutes.

  11. Innovation in Robotic Surgery: The Indian Scenario

    Directory of Open Access Journals (Sweden)

    Suresh V Deshpande

    2015-01-01

    Full Text Available Robotics is the science. In scientific words a "Robot" is an electromechanical arm device with a computer interface, a combination of electrical, mechanical, and computer engineering. It is a mechanical arm that performs tasks in Industries, space exploration, and science. One such idea was to make an automated arm - A robot - In laparoscopy to control the telescope-camera unit electromechanically and then with a computer interface using voice control. It took us 5 long years from 2004 to bring it to the level of obtaining a patent. That was the birth of the Swarup Robotic Arm (SWARM which is the first and the only Indian contribution in the field of robotics in laparoscopy as a total voice controlled camera holding robotic arm developed without any support by industry or research institutes.

  12. Remote Lab for Robotics Applications

    Directory of Open Access Journals (Sweden)

    Robinson Jiménez

    2018-01-01

    Full Text Available This article describes the development of a remote lab environment used to test and training sessions for robotics tasks. This environment is made up of the components and devices based on two robotic arms, a network link, Arduino card and Arduino shield for Ethernet, as well as an IP camera. The remote laboratory is implemented to perform remote control of the robotic arms with visual feedback by camera, of the robots actions, where, with a group of test users, it was possible to obtain performance ranges in tasks of telecontrol of up to 92%.

  13. Human activity understanding for robot-assisted living

    NARCIS (Netherlands)

    Hu, N.

    2016-01-01

    This thesis investigated the problem of understanding human activities, at different levels of granularity and taking into account both the variability in activities and annotator disagreement. To be able to capture the large variations within each of the action classes, we propose a model that uses

  14. Integration of Haptics in Agricultural Robotics

    Science.gov (United States)

    Kannan Megalingam, Rajesh; Sreekanth, M. M.; Sivanantham, Vinu; Sai Kumar, K.; Ghanta, Sriharsha; Surya Teja, P.; Reddy, Rajesh G.

    2017-08-01

    Robots can differentiate with open loop system and closed loop system robots. We face many problems when we do not have a feedback from robots. In this research paper, we are discussing all possibilities to achieve complete closed loop system for Multiple-DOF Robotic Arm, which is used in a coconut tree climbing and cutting robot by introducing a Haptic device. We are working on various sensors like tactile, vibration, force and proximity sensors for getting feedback. For monitoring the robotic arm achieved by graphical user interference software which simulates the working of the robotic arm, send the feedback of all the real time analog values which are produced by various sensors and provide real-time graphs for estimate the efficiency of the Robot.

  15. Friendly network robotics; Friendly network robotics

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    This paper summarizes the research results on the friendly network robotics in fiscal 1996. This research assumes an android robot as an ultimate robot and the future robot system utilizing computer network technology. The robot aiming at human daily work activities in factories or under extreme environments is required to work under usual human work environments. The human robot with similar size, shape and functions to human being is desirable. Such robot having a head with two eyes, two ears and mouth can hold a conversation with human being, can walk with two legs by autonomous adaptive control, and has a behavior intelligence. Remote operation of such robot is also possible through high-speed computer network. As a key technology to use this robot under coexistence with human being, establishment of human coexistent robotics was studied. As network based robotics, use of robots connected with computer networks was also studied. In addition, the R-cube (R{sup 3}) plan (realtime remote control robot technology) was proposed. 82 refs., 86 figs., 12 tabs.

  16. Multimodal Hierarchical Dirichlet Process-Based Active Perception by a Robot

    Directory of Open Access Journals (Sweden)

    Tadahiro Taniguchi

    2018-05-01

    Full Text Available In this paper, we propose an active perception method for recognizing object categories based on the multimodal hierarchical Dirichlet process (MHDP. The MHDP enables a robot to form object categories using multimodal information, e.g., visual, auditory, and haptic information, which can be observed by performing actions on an object. However, performing many actions on a target object requires a long time. In a real-time scenario, i.e., when the time is limited, the robot has to determine the set of actions that is most effective for recognizing a target object. We propose an active perception for MHDP method that uses the information gain (IG maximization criterion and lazy greedy algorithm. We show that the IG maximization criterion is optimal in the sense that the criterion is equivalent to a minimization of the expected Kullback–Leibler divergence between a final recognition state and the recognition state after the next set of actions. However, a straightforward calculation of IG is practically impossible. Therefore, we derive a Monte Carlo approximation method for IG by making use of a property of the MHDP. We also show that the IG has submodular and non-decreasing properties as a set function because of the structure of the graphical model of the MHDP. Therefore, the IG maximization problem is reduced to a submodular maximization problem. This means that greedy and lazy greedy algorithms are effective and have a theoretical justification for their performance. We conducted an experiment using an upper-torso humanoid robot and a second one using synthetic data. The experimental results show that the method enables the robot to select a set of actions that allow it to recognize target objects quickly and accurately. The numerical experiment using the synthetic data shows that the proposed method can work appropriately even when the number of actions is large and a set of target objects involves objects categorized into multiple classes

  17. When Should We Use Care Robots? The Nature-of-Activities Approach

    NARCIS (Netherlands)

    Santoni de Sio, F.; Van Wynsberghe, A.

    2015-01-01

    When should we use care robots? In this paper we endorse the shift from a simple normative approach to care robots ethics to a complex one: we think that one main task of a care robot ethics is that of analysing the different ways in which different care robots may affect the different values at

  18. When Should We Use Care Robots? The Nature-of-Activities Approach

    NARCIS (Netherlands)

    Santoni de Sio, Filippo; van Wynsberghe, Amy Louise

    2016-01-01

    When should we use care robots? In this paper we endorse the shift from a simple normative approach to care robots ethics to a complex one: we think that one main task of a care robot ethics is that of analysing the different ways in which different care robots may affect the different values at

  19. Coupling of biologically active steroids to conjugating arms through ether linkages for use in immunochemistry.

    Science.gov (United States)

    Kohl, Michel J; Lejeune, Robert G

    2002-01-01

    Conjugation of haptens through ether linkages avoids leakage problems in immunoassays, but this procedure is not easily applied to most steroids that bear low reacting hydroxyls. A new technique allowing the ether coupling of biologically active steroids with conjugating arms in mild conditions compatible with thermosensitive protecting groups is presented. In the first step, the solvent (an aromatic hydrocarbon) was dehydrated by azeotropic distillation in a soxhlet apparatus using a cartridge filled with 0.3 nm and 0.4 nm molecular sieves. In this protected medium, a thallium steroid alkoxide was completely formed by reaction of the steroid with thallium ethoxide and by the continuous elimination of ethanol. The halogenated chain was then introduced into the same medium and reacted in the absence of moisture to give the ether. 17beta-Hydroxy and 11alpha-hydroxy derivatives were involved in this reaction. The coupling was effective for all of the compounds tested after 2-36 h of reaction time and at temperatures between 80 and 140 degrees C. The conjugates were at least 95% pure, and yields ranged from 15 to 95%.

  20. A novel optimal coordinated control strategy for the updated robot system for single port surgery.

    Science.gov (United States)

    Bai, Weibang; Cao, Qixin; Leng, Chuntao; Cao, Yang; Fujie, Masakatsu G; Pan, Tiewen

    2017-09-01

    Research into robotic systems for single port surgery (SPS) has become widespread around the world in recent years. A new robot arm system for SPS was developed, but its positioning platform and other hardware components were not efficient. Special features of the developed surgical robot system make good teleoperation with safety and efficiency difficult. A robot arm is combined and used as new positioning platform, and the remote center motion is realized by a new method using active motion control. A new mapping strategy based on kinematics computation and a novel optimal coordinated control strategy based on real-time approaching to a defined anthropopathic criterion configuration that is referred to the customary ease state of human arms and especially the configuration of boxers' habitual preparation posture are developed. The hardware components, control architecture, control system, and mapping strategy of the robotic system has been updated. A novel optimal coordinated control strategy is proposed and tested. The new robot system can be more dexterous, intelligent, convenient and safer for preoperative positioning and intraoperative adjustment. The mapping strategy can achieve good following and representation for the slave manipulator arms. And the proposed novel control strategy can enable them to complete tasks with higher maneuverability, lower possibility of self-interference and singularity free while teleoperating. Copyright © 2017 John Wiley & Sons, Ltd.

  1. Exploratorium: Robots.

    Science.gov (United States)

    Brand, Judith, Ed.

    2002-01-01

    This issue of Exploratorium Magazine focuses on the topic robotics. It explains how to make a vibrating robotic bug and features articles on robots. Contents include: (1) "Where Robot Mice and Robot Men Run Round in Robot Towns" (Ray Bradbury); (2) "Robots at Work" (Jake Widman); (3) "Make a Vibrating Robotic Bug" (Modesto Tamez); (4) "The Robot…

  2. Influence of Arm-cranking on Changes in Plasma CK Activity after High Force Eccentric Exercise of the Elbow Flexors

    OpenAIRE

    Kazunori, NOSAKA; Kei, SAKAMOTO; Mike, NEWTON; Exercise and Sports Science, Graduate School of Integrated Science, Yokohama City University:School of Biomedical and Sports Science, Edith Cowan University; Exercise and Sports Science, Graduate School of Integrated Science, Yokohama City University; School of Biomedical and Sports Science, Edith Cowan University

    2002-01-01

    It was hypothesized that the time course of changes in plasma creatine kinase (CK) activity following eccentric exercise was influenced by rhythmical muscle contractions performed after eccentric exercise. This study examined whether arm-cranking (AC) alters the time course of changes in plasma creatine kinase (CK) activity after eccentric exercise of the elbow flexors (ECC). Six male students performed two bouts of ECC separated by 3 weeks, and AC (25watts, 2-hours) was performed immediately...

  3. The Asteroid Redirect Mission (ARM)

    Science.gov (United States)

    Abell, Paul; Gates, Michele; Johnson, Lindley; Chodas, Paul; Mazanek, Dan; Reeves, David; Ticker, Ronald

    2016-07-01

    To achieve its long-term goal of sending humans to Mars, the National Aeronautics and Space Administration (NASA) plans to proceed in a series of incrementally more complex human spaceflight missions. Today, human flight experience extends only to Low-Earth Orbit (LEO), and should problems arise during a mission, the crew can return to Earth in a matter of minutes to hours. The next logical step for human spaceflight is to gain flight experience in the vicinity of the Moon. These cis-lunar missions provide a "proving ground" for the testing of systems and operations while still accommodating an emergency return path to the Earth that would last only several days. Cis-lunar mission experience will be essential for more ambitious human missions beyond the Earth-Moon system, which will require weeks, months, or even years of transit time. In addition, NASA has been given a Grand Challenge to find all asteroid threats to human populations and know what to do about them. Obtaining knowledge of asteroid physical properties combined with performing technology demonstrations for planetary defense provide much needed information to address the issue of future asteroid impacts on Earth. Hence the combined objectives of human exploration and planetary defense give a rationale for the Asteroid Re-direct Mission (ARM). Mission Description: NASA's ARM consists of two mission segments: 1) the Asteroid Redirect Robotic Mission (ARRM), the first robotic mission to visit a large (greater than ~100 m diameter) near-Earth asteroid (NEA), collect a multi-ton boulder from its surface along with regolith samples, demonstrate a planetary defense technique, and return the asteroidal material to a stable orbit around the Moon; and 2) the Asteroid Redirect Crewed Mission (ARCM), in which astronauts will take the Orion capsule to rendezvous and dock with the robotic vehicle, conduct multiple extravehicular activities to explore the boulder, and return to Earth with samples. NASA's proposed

  4. Ultrasonic decontamination robot

    International Nuclear Information System (INIS)

    Patenaude, R.S.

    1984-01-01

    An ultrasonic decontamination robot removes radioactive contamination from the internal surface of the inlet and outlet headers, divider plate, tube sheet, and lower portions of tubes of a nuclear power plant steam generator. A programmable microprocessor controller guides the movement of a robotic arm mounted in the header manway. An ultrasonic transducer having a solvent delivery subsystem through which ultrasonic action is achieved is moved by the arm over the surfaces. A solvent recovery suction tube is positioned within the header to remove solvent therefrom while avoiding interference with the main robotic arm. The solvent composition, temperature, pressure, viscosity, and purity are controlled to optimize the ultrasonic scrubbing action. The ultrasonic transducer is controlled at a power density, frequency, and on-off mode cycle such as to optimize scrubbing action within the range of transducer-to-surface distance and solvent layer thickness selected for the particular conditions encountered. Both solvent and transducer control actions are optimized by the programmable microprocessor. (author)

  5. Robot-assisted therapy for improving social interactions and activity participation among institutionalized older adults: a pilot study.

    Science.gov (United States)

    Sung, Huei-Chuan; Chang, Shu-Min; Chin, Mau-Yu; Lee, Wen-Li

    2015-03-01

    Animal-assisted therapy is gaining popularity as part of therapeutic activities for older adults in many long-term care facilities. However, concerns about dog bites, allergic responses to pets, disease, and insufficient available resources to care for a real pet have led to many residential care facilities to ban this therapy. There are situations where a substitute artificial companion, such as robotic pet, may serve as a better alternative. This pilot study used a one-group pre- and posttest design to evaluate the effect of a robot-assisted therapy for older adults. Sixteen eligible participants participated in the study and received a group robot-assisted therapy using a seal-like robot pet for 30 minutes twice a week for 4 weeks. All participants received assessments of their communication and interaction skills using the Assessment of Communication and Interaction Skills (ACIS-C) and activity participation using the Activity Participation Scale at baseline and at week 4. A total of 12 participants completed the study. Wilcoxon signed rank test showed that participants' communication and interaction skills (z = -2.94, P = 0.003) and activity participation (z = -2.66, P = 0.008) were significantly improved after receiving 4-week robot-assisted therapy. By interacting with a robot pet, such as Paro, the communication, interaction skills, and activity participation of the older adults can be improved. The robot-assisted therapy can be provided as a routine activity program and has the potential to improve social health of older adults in residential care facilities. Copyright © 2014 Wiley Publishing Asia Pty Ltd.

  6. ARM Tethered Balloon System & AALCO Activities at AMF3 Site at Oliktok Point, AK

    Science.gov (United States)

    Hardesty, J.; Dexheimer, D.; Mei, F.; Roesler, E. L.; Longbottom, C.; Hillman, B. R.

    2017-12-01

    Sandia National Laboratories (SNL) has operated the Atmospheric Radiation Measurement program's (ARM) third ARM Mobile Facility (AMF3) and the restricted airspace associated with it at Oliktok Point, Alaska, since October 2013. The site hosts ground-based instrumentation which collects a variety of continuous atmospheric measurements as well as user-conducted unmanned aircraft and tethered balloon campaigns. SNL has operated ARM's tethered balloon system (TBS) as part of the Inaugural Campaigns for ARM Research using Unmanned Systems (ICARUS) since 2016. AALCO (Aerial Assessment of Liquid in Clouds at Oliktok), is an ARM Intensive Operations Period conducted by SNL at the AMF3 since 2016. The operation of the TBS during ICARUS and AALCO to altitudes above 4,000' AGL in a variety of seasons and conditions is addressed. A Distributed Temperature Sensing (DTS) system and supercooled liquid water content (SLWC) sensors have been deployed under both campaigns. The performance of these sensors is discussed and results are presented. DTS measurements and their relationship to concurrent temperature measurements from unmanned aircraft and radiosondes are shown. SLWC sensor in situ measurements are compared with microwave radiometer and radiosonde-derived measurements. Preliminary analysis of using Large Eddy Simulations to compare with the SLWC measurements reveals three-dimensional properties of the observed clouds.

  7. Inter-rater reliability of kinesthetic measurements with the KINARM robotic exoskeleton.

    Science.gov (United States)

    Semrau, Jennifer A; Herter, Troy M; Scott, Stephen H; Dukelow, Sean P

    2017-05-22

    Kinesthesia (sense of limb movement) has been extremely difficult to measure objectively, especially in individuals who have survived a stroke. The development of valid and reliable measurements for proprioception is important to developing a better understanding of proprioceptive impairments after stroke and their impact on the ability to perform daily activities. We recently developed a robotic task to evaluate kinesthetic deficits after stroke and found that the majority (~60%) of stroke survivors exhibit significant deficits in kinesthesia within the first 10 days post-stroke. Here we aim to determine the inter-rater reliability of this robotic kinesthetic matching task. Twenty-five neurologically intact control subjects and 15 individuals with first-time stroke were evaluated on a robotic kinesthetic matching task (KIN). Subjects sat in a robotic exoskeleton with their arms supported against gravity. In the KIN task, the robot moved the subjects' stroke-affected arm at a preset speed, direction and distance. As soon as subjects felt the robot begin to move their affected arm, they matched the robot movement with the unaffected arm. Subjects were tested in two sessions on the KIN task: initial session and then a second session (within an average of 18.2 ± 13.8 h of the initial session for stroke subjects), which were supervised by different technicians. The task was performed both with and without the use of vision in both sessions. We evaluated intra-class correlations of spatial and temporal parameters derived from the KIN task to determine the reliability of the robotic task. We evaluated 8 spatial and temporal parameters that quantify kinesthetic behavior. We found that the parameters exhibited moderate to high intra-class correlations between the initial and retest conditions (Range, r-value = [0.53-0.97]). The robotic KIN task exhibited good inter-rater reliability. This validates the KIN task as a reliable, objective method for quantifying

  8. Overview and Categorization of Robots Supporting Independent Living of Elderly People: What Activities Do They Support and How Far Have They Developed.

    Science.gov (United States)

    Bedaf, Sandra; Gelderblom, Gert Jan; De Witte, Luc

    2015-01-01

    Over the past decades, many robots for the elderly have been developed, supporting different activities of elderly people. A systematic review in four scientific literature databases and a search in article references and European projects was performed in order to create an overview of robots supporting independent living of elderly people. The robots found were categorized based on their development stage, the activity domains they claim to support, and the type of support provided (i.e., physical, non-physical, and/or non-specified). In total, 107 robots for the elderly were identified. Six robots were still in a concept phase, 95 in a development phase, and six of these robots were commercially available. These robots claimed to provide support related to four activity domains: mobility, self-care, interpersonal interaction & relationships, and other activities. Of the many robots developed, only a small percentage is commercially available. Technical ambitions seem to be guiding robot development. To prolong independent living, the step towards physical support is inevitable and needs to be taken. However, it will be a long time before a robot will be capable of supporting multiple activities in a physical manner in the home of an elderly person in order to enhance their independent living.

  9. Robot off-line programming and simulation as a true CIME-subsystem

    DEFF Research Database (Denmark)

    Nielsen, L.F; Trostmann, S; Trostmann, Erik

    1992-01-01

    A robot off-line programming and real-time simulation system, ROPSIM, which is based on the neutral interface concept and features simulation of the dynamics of both the controller and robot arm, has been developed. To avoid dependency on dedicated robot models, ROPSIM is based on generic models...... describing the robot controller, robot arm geometry, and the robot and arm kinetics. The software was developed using the C++ programming language. The key modules are discussed. The system is a true computer-integrated manufacturing and engineering subsystem which facilitates the exchange and reuse of robot...... model definition data and robot program definition data with systems of other origin or different functionality...

  10. The SHERPA project: Smart collaboration between humans and ground-aerial robots for improving rescuing activities in alpine environments

    NARCIS (Netherlands)

    Marconi, L.; Melchiorri, C.; Beetz, M.; Pangercic, D.; Siegwart, R.; Leutenegger, S.; Carloni, Raffaella; Stramigioli, Stefano; Bruyninckx, H.; Doherty, P.; Kleiner, A.; Lippiello, V.; Finzi, A.; Siciliano, B.; Sala, A.; Tomatis, N.

    2012-01-01

    The goal of the paper is to present the foreseen research activity of the European project “SHERPA‿ whose activities will start officially on February 1th 2013. The goal of SHERPA is to develop a mixed ground and aerial robotic platform to support search and rescue activities in a real-world hostile

  11. Robot-assisted motor activation monitored by time-domain optical brain imaging

    Science.gov (United States)

    Steinkellner, O.; Wabnitz, H.; Schmid, S.; Steingräber, R.; Schmidt, H.; Krüger, J.; Macdonald, R.

    2011-07-01

    Robot-assisted motor rehabilitation proved to be an effective supplement to conventional hand-to-hand therapy in stroke patients. In order to analyze and understand motor learning and performance during rehabilitation it is desirable to develop a monitor to provide objective measures of the corresponding brain activity at the rehabilitation progress. We used a portable time-domain near-infrared reflectometer to monitor the hemodynamic brain response to distal upper extremity activities. Four healthy volunteers performed two different robot-assisted wrist/forearm movements, flexion-extension and pronation-supination in comparison with an unassisted squeeze ball exercise. A special headgear with four optical measurement positions to include parts of the pre- and postcentral gyrus provided a good overlap with the expected activation areas. Data analysis based on variance of time-of-flight distributions of photons through tissue was chosen to provide a suitable representation of intracerebral signals. In all subjects several of the four detection channels showed a response. In some cases indications were found of differences in localization of the activated areas for the various tasks.

  12. Human-robot interaction: kinematics and muscle activity inside a powered compliant knee exoskeleton.

    Science.gov (United States)

    Knaepen, Kristel; Beyl, Pieter; Duerinck, Saartje; Hagman, Friso; Lefeber, Dirk; Meeusen, Romain

    2014-11-01

    Until today it is not entirely clear how humans interact with automated gait rehabilitation devices and how we can, based on that interaction, maximize the effectiveness of these exoskeletons. The goal of this study was to gain knowledge on the human-robot interaction, in terms of kinematics and muscle activity, between a healthy human motor system and a powered knee exoskeleton (i.e., KNEXO). Therefore, temporal and spatial gait parameters, human joint kinematics, exoskeleton kinetics and muscle activity during four different walking trials in 10 healthy male subjects were studied. Healthy subjects can walk with KNEXO in patient-in-charge mode with some slight constraints in kinematics and muscle activity primarily due to inertia of the device. Yet, during robot-in-charge walking the muscular constraints are reversed by adding positive power to the leg swing, compensating in part this inertia. Next to that, KNEXO accurately records and replays the right knee kinematics meaning that subject-specific trajectories can be implemented as a target trajectory during assisted walking. No significant differences in the human response to the interaction with KNEXO in low and high compliant assistance could be pointed out. This is in contradiction with our hypothesis that muscle activity would decrease with increasing assistance. It seems that the differences between the parameter settings of low and high compliant control might not be sufficient to observe clear effects in healthy subjects. Moreover, we should take into account that KNEXO is a unilateral, 1 degree-of-freedom device.

  13. Reasons for singularity in robot teleoperation

    DEFF Research Database (Denmark)

    Marhenke, Ilka; Fischer, Kerstin; Savarimuthu, Thiusius Rajeeth

    2014-01-01

    In this paper, the causes for singularity of a robot arm in teleoperation for robot learning from demonstration are analyzed. Singularity is the alignment of robot joints, which prevents the configuration of the inverse kinematics. Inspired by users' own hypotheses, we investigated speed and dela...

  14. Transferring human impedance regulation skills to robots

    CERN Document Server

    Ajoudani, Arash

    2016-01-01

    This book introduces novel thinking and techniques to the control of robotic manipulation. In particular, the concept of teleimpedance control as an alternative method to bilateral force-reflecting teleoperation control for robotic manipulation is introduced. In teleimpedance control, a compound reference command is sent to the slave robot including both the desired motion trajectory and impedance profile, which are then realized by the remote controller. This concept forms a basis for the development of the controllers for a robotic arm, a dual-arm setup, a synergy-driven robotic hand, and a compliant exoskeleton for improved interaction performance.

  15. System for exchanging tools and end effectors on a robot

    International Nuclear Information System (INIS)

    Burry, D.B.; Williams, P.M.

    1991-01-01

    A system and method for exchanging tools and end effectors on a robot permits exchange during a programmed task. The exchange mechanism is located off the robot, thus reducing the mass of the robot arm and permitting smaller robots to perform designated tasks. A simple spring/collet mechanism mounted on the robot is used which permits the engagement and disengagement of the tool or end effector without the need for a rotational orientation of the tool to the end effector/collet interface. As the tool changing system is not located on the robot arm no umbilical cords are located on robot. 12 figures

  16. Arm Pain

    Science.gov (United States)

    ... be a sign of a heart attack. Seek emergency treatment if you have: Arm, shoulder or back ... http://www.mayoclinic.org/symptoms/arm-pain/basics/definition/SYM-20050870 . Mayo Clinic Footer Legal Conditions and ...

  17. Dynamics, control and sensor issues pertinent to robotic hands for the EVA retriever system

    Science.gov (United States)

    Mclauchlan, Robert A.

    1987-01-01

    Basic dynamics, sensor, control, and related artificial intelligence issues pertinent to smart robotic hands for the Extra Vehicular Activity (EVA) Retriever system are summarized and discussed. These smart hands are to be used as end effectors on arms attached to manned maneuvering units (MMU). The Retriever robotic systems comprised of MMU, arm and smart hands, are being developed to aid crewmen in the performance of routine EVA tasks including tool and object retrieval. The ultimate goal is to enhance the effectiveness of EVA crewmen.

  18. Passive Reactive Berm to Provide Low Maintenance Lead Containment at Active Small Arms Firing Ranges: Field Demonstration

    Science.gov (United States)

    2012-08-01

    Containment at Active Small Arms Firing Ranges Field Demonstration E nv ir on m en ta l L ab or at or y Michelle Wynter, Steven L. Larson, W.A...efficiency of 37 to 100 percent can be achieved through the process of hydroxyapatite dissolution and hydroxypyromorphite [Pb10(PO4)6(OH)2...al. 2006; Tardy et al. 2003; USEPA 2001a). Application of soluble or solid phase phosphate (such as hydroxyapatite , HAP) amendments have been shown

  19. Soft brain-machine interfaces for assistive robotics: A novel control approach.

    Science.gov (United States)

    Schiatti, Lucia; Tessadori, Jacopo; Barresi, Giacinto; Mattos, Leonardo S; Ajoudani, Arash

    2017-07-01

    Robotic systems offer the possibility of improving the life quality of people with severe motor disabilities, enhancing the individual's degree of independence and interaction with the external environment. In this direction, the operator's residual functions must be exploited for the control of the robot movements and the underlying dynamic interaction through intuitive and effective human-robot interfaces. Towards this end, this work aims at exploring the potential of a novel Soft Brain-Machine Interface (BMI), suitable for dynamic execution of remote manipulation tasks for a wide range of patients. The interface is composed of an eye-tracking system, for an intuitive and reliable control of a robotic arm system's trajectories, and a Brain-Computer Interface (BCI) unit, for the control of the robot Cartesian stiffness, which determines the interaction forces between the robot and environment. The latter control is achieved by estimating in real-time a unidimensional index from user's electroencephalographic (EEG) signals, which provides the probability of a neutral or active state. This estimated state is then translated into a stiffness value for the robotic arm, allowing a reliable modulation of the robot's impedance. A preliminary evaluation of this hybrid interface concept provided evidence on the effective execution of tasks with dynamic uncertainties, demonstrating the great potential of this control method in BMI applications for self-service and clinical care.

  20. Toward Multimodal Human-Robot Interaction to Enhance Active Participation of Users in Gait Rehabilitation.

    Science.gov (United States)

    Gui, Kai; Liu, Honghai; Zhang, Dingguo

    2017-11-01

    Robotic exoskeletons for physical rehabilitation have been utilized for retraining patients suffering from paraplegia and enhancing motor recovery in recent years. However, users are not voluntarily involved in most systems. This paper aims to develop a locomotion trainer with multiple gait patterns, which can be controlled by the active motion intention of users. A multimodal human-robot interaction (HRI) system is established to enhance subject's active participation during gait rehabilitation, which includes cognitive HRI (cHRI) and physical HRI (pHRI). The cHRI adopts brain-computer interface based on steady-state visual evoked potential. The pHRI is realized via admittance control based on electromyography. A central pattern generator is utilized to produce rhythmic and continuous lower joint trajectories, and its state variables are regulated by cHRI and pHRI. A custom-made leg exoskeleton prototype with the proposed multimodal HRI is tested on healthy subjects and stroke patients. The results show that voluntary and active participation can be effectively involved to achieve various assistive gait patterns.

  1. Reviewing Clinical Effectiveness of Active Training Strategies of Platform-Based Ankle Rehabilitation Robots

    Directory of Open Access Journals (Sweden)

    Xiangfeng Zeng

    2018-01-01

    Full Text Available Objective. This review aims to provide a systematical investigation of clinical effectiveness of active training strategies applied in platform-based ankle robots. Method. English-language studies published from Jan 1980 to Aug 2017 were searched from four databases using key words of “Ankle∗” AND “Robot∗” AND “Effect∗ OR Improv∗ OR Increas∗.” Following an initial screening, three rounds of discrimination were successively conducted based on the title, the abstract, and the full paper. Result. A total of 21 studies were selected with 311 patients involved; of them, 13 studies applied a single group while another eight studies used different groups for comparison to verify the therapeutic effect. Virtual-reality (VR game training was applied in 19 studies, while two studies used proprioceptive neuromuscular facilitation (PNF training. Conclusion. Active training techniques delivered by platform ankle rehabilitation robots have been demonstrated with great potential for clinical applications. Training strategies are mostly combined with one another by considering rehabilitation schemes and motion ability of ankle joints. VR game environment has been commonly used with active ankle training. Bioelectrical signals integrated with VR game training can implement intelligent identification of movement intention and assessment. These further provide the foundation for advanced interactive training strategies that can lead to enhanced training safety and confidence for patients and better treatment efficacy.

  2. Robots in the Roses

    OpenAIRE

    2014-01-01

    2014-04 Robots in the Roses A CRUSER Sponsored Event. The 4th Annual Robots in the Roses provides a venue for Faculty & NPS Students to showcase unmanned systems research (current or completed) and recruit NPS Students to join in researching on your project. Posters, robots, vehicles, videos, and even just plain humans welcome! Families are welcome to attend Robots in the Roses as we'll have a STEM activity for children to participate in.

  3. Results of clinicians using a therapeutic robotic system in an inpatient stroke rehabilitation unit.

    Science.gov (United States)

    Abdullah, Hussein A; Tarry, Cole; Lambert, Cynthia; Barreca, Susan; Allen, Brian O

    2011-08-26

    Physical rehabilitation is an area where robotics could contribute significantly to improved motor return for individuals following a stroke. This paper presents the results of a preliminary randomized controlled trial (RCT) of a robot system used in the rehabilitation of the paretic arm following a stroke. The study's objectives were to explore the efficacy of this new type of robotic therapy as compared to standard physiotherapy treatment in treating the post-stroke arm; to evaluate client satisfaction with the proposed robotic system; and to provide data for sample size calculations for a proposed larger multicenter RCT. Twenty clients admitted to an inpatient stroke rehabilitation unit were randomly allocated to one of two groups, an experimental (robotic arm therapy) group or a control group (conventional therapy). An occupational therapist blinded to patient allocation administered two reliable measures, the Chedoke Arm and Hand Activity Inventory (CAHAI-7) and the Chedoke McMaster Stroke Assessment of the Arm and Hand (CMSA) at admission and discharge. For both groups, at admission, the CMSA motor impairment stage of the affected arm was between 1 and 3. Data were compared to determine the effectiveness of robot-assisted versus conventional therapy treatments. At the functional level, both groups performed well, with improvement in scores on the CAHAI-7 showing clinical and statistical significance. The CAHAI-7 (range7-49) is a measure of motor performance using functional items. Individuals in the robotic therapy group, on average, improved by 62% (95% CI: 26% to 107%) while those in the conventional therapy group changed by 30% (95% CI: 4% to 61%). Although performance on this measure is influenced by hand recovery, our results showed that both groups had similar stages of motor impairment in the hand. Furthermore, the degree of shoulder pain, as measured by the CMSA pain inventory scale, did not worsen for either group over the course of treatment. Our

  4. A Sit-to-Stand Training Robot and Its Performance Evaluation: Dynamic Analysis in Lower Limb Rehabilitation Activities

    Science.gov (United States)

    Cao, Enguo; Inoue, Yoshio; Liu, Tao; Shibata, Kyoko

    In many countries in which the phenomenon of population aging is being experienced, motor function recovery activities have aroused much interest. In this paper, a sit-to-stand rehabilitation robot utilizing a double-rope system was developed, and the performance of the robot was evaluated by analyzing the dynamic parameters of human lower limbs. For the robot control program, an impedance control method with a training game was developed to increase the effectiveness and frequency of rehabilitation activities, and a calculation method was developed for evaluating the joint moments of hip, knee, and ankle. Test experiments were designed, and four subjects were requested to stand up from a chair with assistance from the rehabilitation robot. In the experiments, body segment rotational angles, trunk movement trajectories, rope tensile forces, ground reaction forces (GRF) and centers of pressure (COP) were measured by sensors, and the moments of ankle, knee and hip joint were real-time calculated using the sensor-measured data. The experiment results showed that the sit-to-stand rehabilitation robot with impedance control method could maintain the comfortable training postures of users, decrease the moments of limb joints, and enhance training effectiveness. Furthermore, the game control method could encourage collaboration between the brain and limbs, and allow for an increase in the frequency and intensity of rehabilitation activities.

  5. New approach to evaluate late arm impairment and effects of dragon boat activity in breast cancer survivors.

    Science.gov (United States)

    Melchiorri, Giovanni; Viero, Valerio; Triossi, Tamara; Sorge, Roberto; Tancredi, Virginia; Cafaro, Domenico; Andreis, Caterina; Vulpiani, Maria Chiara; Saraceni, Vincenzo Maria

    2017-11-01

    To verify the applicability of a new approach based on the strength curves (SCs) methodology in late arm impairment in breast cancer (BC) survivors and to evaluate the effects of dragon boat (DB) activity on the late regaining of the muscle strength, upper limb impairment, and quality of life in patients undergoing surgery for BC.Retrospective observational study on 64 subjects (54.5 ± 9.7 years), 47 of them had undergone unilateral mastectomy surgery and were evaluated for late arm impairment. A clinical evaluation of the shoulder and compilation of functional assessment (DASH, Rowe, Constant-Murley) and quality of life (SF-36) scales were carried out. Assessment of muscle strength with SC obtained with isometric assessments and serratus anterior muscle test were performed.Differences between the SC are evident between healthy and operated subjects. Among the 3 groups of operated subjects the difference in strength is maximum at 0°. Statistically significant difference was found between operated and nonoperated only in SF-36 scale. No significant difference was found between groups for shoulder instability and winged scapula.The SC can be used in the study of upper limb impairment after surgery for BC: measurements carried out at 1st degrees of the range of motion are more useful for clinicians. DB activity is useful to reduce the late arm impairment.

  6. Robotic therapy provides a stimulus for upper limb motor recovery after stroke that is complementary to and distinct from conventional therapy.

    Science.gov (United States)

    Brokaw, Elizabeth B; Nichols, Diane; Holley, Rahsaan J; Lum, Peter S

    2014-05-01

    Individuals with chronic stroke often have long-lasting upper extremity impairments that impede function during activities of daily living. Rehabilitation robotics have shown promise in improving arm function, but current systems do not allow realistic training of activities of daily living. We have incorporated the ARMin III and HandSOME device into a novel robotic therapy modality that provides functional training of reach and grasp tasks. To compare the effects of equal doses of robotic and conventional therapy in individuals with chronic stroke. Subjects were randomized to 12 hours of robotic or conventional therapy and then crossed over to the other therapy type after a 1-month washout period. Twelve moderate to severely impaired individuals with chronic stroke were enrolled, and 10 completed the study. Across the 3-month study period, subjects showed significant improvements in the Fugl-Meyer (P = .013) and Box and Blocks tests (P = .028). The robotic intervention produced significantly greater improvements in the Action Research Arm Test than conventional therapy (P = .033). Gains in the Box and Blocks test from conventional therapy were larger than from robotic therapy in subjects who received conventional therapy after robotic therapy (P = .044). Data suggest that robotic therapy can elicit improvements in arm function that are distinct from conventional therapy and supplements conventional methods to improve outcomes. Results from this pilot study should be confirmed in a larger study.

  7. Remote controlled data collector robot

    Directory of Open Access Journals (Sweden)

    Jozsef Suto

    2012-06-01

    Full Text Available Today a general need for robots assisting different human activities rises. The goal of the present project is to develop a prototyping robot, which provides facilities for attaching and fitting different kinds of sensors and actuators. This robot provides an easy way to turn a general purpose robot into a special function one.

  8. Evaluation of reach and grasp robot-assisted therapy suggests similar functional recovery patterns on proximal and distal arm segments in sub-acute hemiplegia.

    Science.gov (United States)

    Loureiro, Rui C V; Harwin, William S; Lamperd, Robert; Collin, Christine

    2014-05-01

    This paper provides some additional evidence in support of the hypothesis that robot therapies are clinically beneficial in neurorehabilitation. Although only four subjects were included in the study, the design of the intervention and the measures were done so as to minimize bias. The results are presented as single case studies, and can only be interpreted as such due to the study size. The intensity of intervention was 16 h and the therapy philosophy (based on Carr and Shepherd) was that coordinated movements are preferable to joint based therapies, and that coordinating distal movements (in this case grasps) helps not only to recover function in these areas, but has greater value since the results are immediately transferable to daily skills such as reach and grasp movements.

  9. Robot Actors, Robot Dramaturgies

    DEFF Research Database (Denmark)

    Jochum, Elizabeth

    This paper considers the use of tele-operated robots in live performance. Robots and performance have long been linked, from the working androids and automata staged in popular exhibitions during the nineteenth century and the robots featured at Cybernetic Serendipity (1968) and the World Expo...

  10. Pneumatic tool torque reaction: reaction forces, displacement, muscle activity and discomfort in the hand-arm system.

    Science.gov (United States)

    Kihlberg, S; Kjellberg, A; Lindbeck, L

    1993-06-01

    Reaction forces, hand-arm displacement, muscle activity and discomfort ratings were studied during the securing of threaded fasteners with three angle nutrunners with different shut-off mechanisms, but with the same spindle torque (72-74 Nm). The three tools were tested according to the method specified in ISO 6544. One of the tools had an almost instantaneous shut-off. Another had a more slowly declining torque curve. For the third tool the maximum torque was maintained for a while before shut-off. Twelve male subjects participated in the study. A force platform measured the reaction force between the subject and the floor. The option of the hand-arm system and the shoulder was measured with an optoelectronic measuring system. The muscle activity (EMG) in six muscles in the arm and shoulder was measured with surface electrodes. Significant differences in the arm movements and ground reaction forces were found between the three tools. The smallest values were found with the fast shut-off tool while the delayed shut-off tool caused the largest values. The EMG measures gave inconsistent response patterns. Discomfort ratings were highly correlated with the time for which the tool torque exceeded 90% of peak preset torque, but the time for which the tool torque exceeded 90% of peak calculated by the method specified in ISO 6544. Nutrunners with a shut-off mechanism that causes a slowly decreasing torque or a torque that is maintained for a while before shut-off should be avoided. If no substitutes are available, then a torque reaction bar should be mounted on the tool.

  11. A Computational Mechatronics Approach for the Analysis, Synthesis and Design of a Simple Active Biped Robot: Theory and Experiments

    Directory of Open Access Journals (Sweden)

    L.-I. Lugo-Villeda

    2006-01-01

    Full Text Available Biped walking is a quite complex process that has been mastered only by human beings. Transferring this skill to a robot requires implementing advanced techniques in every aspect. To this end, a computational mechatronics platform was integrated to run the scheme for the analysis, synthesis and design to achieve planar biped walking. The result is an advanced computational tool that integrates advanced modeling and control as well as path planning techniques along with hardware-in-the-loop for perhaps the simplest biped robot. An experimental underactuated three-degree-of-freedom (two active and one passive active biped robot yields encouraging results; that is, achieving biped walking with this simple device requires adding a telescopic support leg. Considering a more complete dynamic model to take into account frictional and contact forces.

  12. Robotic architectures

    CSIR Research Space (South Africa)

    Mtshali, M

    2010-01-01

    Full Text Available In the development of mobile robotic systems, a robotic architecture plays a crucial role in interconnecting all the sub-systems and controlling the system. The design of robotic architectures for mobile autonomous robots is a challenging...

  13. Experimental Study of Active Vibration Control of Planar 3-RRR Flexible Parallel Robots Mechanism

    Directory of Open Access Journals (Sweden)

    Qinghua Zhang

    2016-01-01

    Full Text Available An active vibration control experiment of planar 3-RRR flexible parallel robots is implemented in this paper. Considering the direct and inverse piezoelectric effect of PZT material, a general motion equation is established. A strain rate feedback controller is designed based on the established general motion equation. Four control schemes are designed in this experiment: three passive flexible links are controlled at the same time, only passive flexible link 1 is controlled, only passive flexible link 2 is controlled, and only passive flexible link 3 is controlled. The experimental results show that only one flexible link controlled scheme  suppresses elastic vibration and cannot suppress the elastic vibration of the other flexible links, whereas when three passive flexible links are controlled at the same time, they are able to effectively suppress the elastic vibration of all of the flexible links. In general, the experiment verifies that a strain rate feedback controller is able to effectively suppress the elastic vibration of the flexible links of plane 3-RRR flexible parallel robots.

  14. Robotic identification of kinesthetic deficits after stroke.

    Science.gov (United States)

    Semrau, Jennifer A; Herter, Troy M; Scott, Stephen H; Dukelow, Sean P

    2013-12-01

    Kinesthesia, the sense of body motion, is essential to proper control and execution of movement. Despite its importance for activities of daily living, no current clinical measures can objectively measure kinesthetic deficits. The goal of this study was to use robotic technology to quantify prevalence and severity of kinesthetic deficits of the upper limb poststroke. Seventy-four neurologically intact subjects and 113 subjects with stroke (62 left-affected, 51 right-affected) performed a robot-based kinesthetic matching task with vision occluded. The robot moved the most affected arm at a preset speed, direction, and magnitude. Subjects were instructed to mirror-match the movement with their opposite arm (active arm). A large number of subjects with stroke were significantly impaired on measures of kinesthesia. We observed impairments in ability to match movement direction (69% and 49% impaired for left- and right-affected subjects, respectively) and movement magnitude (42% and 31%). We observed impairments to match movement speed (32% and 27%) and increased response latencies (48% and 20%). Movement direction errors and response latencies were related to clinical measures of function, motor recovery, and dexterity. Using a robotic approach, we found that 61% of acute stroke survivors (n=69) had kinesthetic deficits. Additionally, these deficits were highly related to existing clinical measures, suggesting the importance of kinesthesia in day-to-day function. Our methods allow for more sensitive, accurate, and objective identification of kinesthetic deficits after stroke. With this information, we can better inform clinical treatment strategies to improve poststroke rehabilitative care and outcomes.

  15. Robotics Offer Newfound Surgical Capabilities

    Science.gov (United States)

    2008-01-01

    Barrett Technology Inc., of Cambridge, Massachusetts, completed three Phase II Small Business Innovation Research (SBIR) contracts with Johnson Space Center, during which the company developed and commercialized three core technologies: a robotic arm, a hand that functions atop the arm, and a motor driver to operate the robotics. Among many industry uses, recently, an adaptation of the arm has been cleared by the U.S. Food and Drug Administration (FDA) for use in a minimally invasive knee surgery procedure, where its precision control makes it ideal for inserting a very small implant.

  16. Nonspecific Arm Pain

    Directory of Open Access Journals (Sweden)

    Ali Moradi

    2013-12-01

    Full Text Available Nonspecific activity-related arm pain is characterized by an absence of objective physical findings and symptoms that do not correspond with objective pathophysiology. Arm pain without strict diagnosis is often related to activity, work-related activity in particular, and is often seen in patients with physically demanding work. Psychological factors such as catastrophic thinking, symptoms of depression, and heightened illness concern determine a substantial percentage of the disability associated with puzzling hand and arm pains. Ergonomic modifications can help to control symptoms, but optimal health may require collaborative management incorporating psychosocial and psychological elements of illness.

  17. Nonspecific Arm Pain

    Directory of Open Access Journals (Sweden)

    Ali Moradi

    2013-12-01

    Full Text Available   Nonspecific activity-related arm pain is characterized by an absence of objective physical findings and symptoms that do not correspond with objective pathophysiology. Arm pain without strict diagnosis is often related to activity, work-related activity in particular, and is often seen in patients with physically demanding work. Psychological factors such as catastrophic thinking, symptoms of depression, and heightened illness concern determine a substantial percentage of the disability associated with puzzling hand and arm pains. Ergonomic modifications can help to control symptoms, but optimal health may require collaborative management incorporating psychosocial and psychological elements of illness.

  18. Reaction Null Space of a multibody system with applications in robotics

    Directory of Open Access Journals (Sweden)

    D. N. Nenchev

    2013-02-01

    Full Text Available This paper provides an overview of implementation examples based on the Reaction Null Space formalism, developed initially to tackle the problem of satellite-base disturbance of a free-floating space robot, when the robot arm is activated. The method has been applied throughout the years to other unfixed-base systems, e.g. flexible-base and macro/mini robot systems, as well as to the balance control problem of humanoid robots. The paper also includes most recent results about complete dynamical decoupling of the end-link of a fixed-base robot, wherein the end-link is regarded as the unfixed-base. This interpretation is shown to be useful with regard to motion/force control scenarios. Respective implementation results are provided.

  19. Optimalisasi Ukuran Manipulabilitas Robot Stanford Menggunakan Metode Pseudo-inverse

    OpenAIRE

    admin, Gina Fahrina

    2013-01-01

    Robot is one of the most important element in the industrial world which has been growing very rapidly. Stanford robot arm is one of robot that use in industry, it has five degrees of freedom (DOF). Movement of the robot arm in his workspace called manipulability or manipulability measure. More the optimal manipulability measure manipulator, the more movement of the robotic arm will be more flexible in his workspace. The purpose of this research are to get knowledge and learn how to solve inv...

  20. Medical Robots: Current Systems and Research Directions

    Directory of Open Access Journals (Sweden)

    Ryan A. Beasley

    2012-01-01

    Full Text Available First used medically in 1985, robots now make an impact in laparoscopy, neurosurgery, orthopedic surgery, emergency response, and various other medical disciplines. This paper provides a review of medical robot history and surveys the capabilities of current medical robot systems, primarily focusing on commercially available systems while covering a few prominent research projects. By examining robotic systems across time and disciplines, trends are discernible that imply future capabilities of medical robots, for example, increased usage of intraoperative images, improved robot arm design, and haptic feedback to guide the surgeon.

  1. Activation timing of postural muscles of lower legs and prediction of postural disturbance during bilateral arm flexion in older adults.

    Science.gov (United States)

    Yaguchi, Chie; Fujiwara, Katsuo; Kiyota, Naoe

    2017-12-22

    Activation timings of postural muscles of lower legs and prediction of postural disturbance were investigated in young and older adults during bilateral arm flexion in a self-timing task and an oddball task with different probabilities of target presentation. Arm flexion was started from a standing posture with hands suspended 10 cm below the horizontal level in front of the body, in which postural control focused on the ankles is important. Fourteen young and 14 older adults raised the arms in response to the target sound signal. Three task conditions were used: 15 and 45% probabilities of the target in the oddball task and self-timing. Analysis items were activation timing of postural muscles (erector spinae, biceps femoris, and gastrocnemius) with respect to the anterior deltoid (AD), and latency and amplitude of the P300 component of event-related brain potential. For young adults, all postural muscles were activated significantly earlier than AD under each condition, and time of preceding gastrocnemius activation was significantly longer in the order of the self-timing, 45 and 15% conditions. P300 latency was significantly shorter, and P300 amplitude was significantly smaller under the 45% condition than under the 15% condition. For older adults, although all postural muscles, including gastrocnemius, were activated significantly earlier than AD in the self-timing condition, only activation timing of gastrocnemius was not significantly earlier than that of AD in oddball tasks, regardless of target probability. No significant differences were found between 15 and 45% conditions in onset times of all postural muscles, and latency and amplitude of P300. These results suggest that during arm movement, young adults can achieve sufficient postural preparation in proportion to the probability of target presentation in the oddball task. Older adults can achieve postural control using ankle joints in the self-timing task. However, in the oddball task, older adults

  2. Effect of Tendon Vibration on Hemiparetic Arm Stability in Unstable Workspaces.

    Directory of Open Access Journals (Sweden)

    Megan O Conrad

    Full Text Available Sensory stimulation of wrist musculature can enhance stability in the proximal arm and may be a useful therapy aimed at improving arm control post-stroke. Specifically, our prior research indicates tendon vibration can enhance stability during point-to-point arm movements and in tracking tasks. The goal of the present study was to investigate the influence of forearm tendon vibration on endpoint stability, measured at the hand, immediately following forward arm movements in an unstable environment. Both proximal and distal workspaces were tested. Ten hemiparetic stroke subjects and 5 healthy controls made forward arm movements while grasping the handle of a two-joint robotic arm. At the end of each movement, the robot applied destabilizing forces. During some trials, 70 Hz vibration was applied to the forearm flexor muscle tendons. 70 Hz was used as the stimulus frequency as it lies within the range of optimal frequencies that activate the muscle spindles at the highest response rate. Endpoint position, velocity, muscle activity and grip force data were compared before, during and after vibration. Stability at the endpoint was quantified as the magnitude of oscillation about the target position, calculated from the power of the tangential velocity data. Prior to vibration, subjects produced unstable, oscillating hand movements about the target location due to the applied force field. Stability increased during vibration, as evidenced by decreased oscillation in hand tangential velocity.

  3. Performing mathematics activities with non-standard units of measurement using robots controlled via speech-generating devices: three case studies.

    Science.gov (United States)

    Adams, Kim D; Cook, Albert M

    2017-07-01

    Purpose To examine how using a Lego robot controlled via a speech-generating device (SGD) can contribute to how students with physical and communication impairments perform hands-on and communicative mathematics measurement activities. This study was a follow-up to a previous study. Method Three students with cerebral palsy used the robot to measure objects using non-standard units, such as straws, and then compared and ordered the objects using the resulting measurement. Their performance was assessed, and the manipulation and communication events were observed. Teachers and education assistants were interviewed regarding robot use. Results Similar benefits to the previous study were found in this study. Gaps in student procedural knowledge were identified such as knowing to place measurement units tip-to-tip, and students' reporting revealed gaps in conceptual understanding. However, performance improved with repeated practice. Stakeholders identified that some robot tasks took too long or were too difficult to perform. Conclusions Having access to both their SGD and a robot gave the students multiple ways to show their understanding of the measurement concepts. Though they could participate actively in the new mathematics activities, robot use is most appropriate in short tasks requiring reasonable operational skill. Implications for Rehabilitation Lego robots controlled via speech-generating devices (SGDs) can help students to engage in the mathematics pedagogy of performing hands-on activities while communicating about concepts. Students can "show what they know" using the Lego robots, and report and reflect on concepts using the SGD. Level 1 and Level 2 mathematics measurement activities have been adapted to be accomplished by the Lego robot. Other activities can likely be accomplished with similar robot adaptations (e.g., gripper, pen). It is not recommended to use the robot to measure items that are long, or perform measurements that require high

  4. Innovations in robotic surgery.

    Science.gov (United States)

    Gettman, Matthew; Rivera, Marcelino

    2016-05-01

    Developments in robotic surgery have continued to advance care throughout the field of urology. The purpose of this review is to evaluate innovations in robotic surgery over the past 18 months. The release of the da Vinci Xi system heralded an improvement on the Si system with improved docking, the ability to further manipulate robotic arms without clashing, and an autofocus universal endoscope. Robotic simulation continues to evolve with improvements in simulation training design to include augmented reality in robotic surgical education. Robotic-assisted laparoendoscopic single-site surgery continues to evolve with improvements on technique that allow for tackling previously complex pathologic surgical anatomy including urologic oncology and reconstruction. Last, innovations of new surgical platforms with robotic systems to improve surgeon ergonomics and efficiency in ureteral and renal surgery are being applied in the clinical setting. Urologic surgery continues to be at the forefront of the revolution of robotic surgery with advancements in not only existing technology but also creation of entirely novel surgical systems.

  5. Human-robot skills transfer interfaces for a flexible surgical robot.

    Science.gov (United States)

    Calinon, Sylvain; Bruno, Danilo; Malekzadeh, Milad S; Nanayakkara, Thrishantha; Caldwell, Darwin G

    2014-09-01

    In minimally invasive surgery, tools go through narrow openings and manipulate soft organs to perform surgical tasks. There are limitations in current robot-assisted surgical systems due to the rigidity of robot tools. The aim of the STIFF-FLOP European project is to develop a soft robotic arm to perform surgical tasks. The flexibility of the robot allows the surgeon to move within organs to reach remote areas inside the body and perform challenging procedures in laparoscopy. This article addresses the problem of designing learning interfaces enabling the transfer of skills from human demonstration. Robot programming by demonstration encompasses a wide range of learning strategies, from simple mimicking of the demonstrator's actions to the higher level imitation of the underlying intent extracted from the demonstrations. By focusing on this last form, we study the problem of extracting an objective function explaining the demonstrations from an over-specified set of candidate reward functions, and using this information for self-refinement of the skill. In contrast to inverse reinforcement learning strategies that attempt to explain the observations with reward functions defined for the entire task (or a set of pre-defined reward profiles active for different parts of the task), the proposed approach is based on context-dependent reward-weighted learning, where the robot can learn the relevance of candidate objective functions with respect to the current phase of the task or encountered situation. The robot then exploits this information for skills refinement in the policy parameters space. The proposed approach is tested in simulation with a cutting task performed by the STIFF-FLOP flexible robot, using kinesthetic demonstrations from a Barrett WAM manipulator. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. An Exploration of Developing Active Exploring and Problem Solving Skill Lego Robot Course by the Application of Anchored Instruction Theory

    Science.gov (United States)

    Chen, Chen-Yuan

    2013-01-01

    In recent years, researches had shown that the development of problem solving skill became important for education, and the educational robots are capable for promoting students not only understand the physical and mathematical concepts, but also have active and constructive learning. Meanwhile, the importance of situation in education is rising,…

  7. The effects on Kinematics and Muscle Activity of Walking in a Robotic Gait Trainer During Zero-Force Control

    NARCIS (Netherlands)

    van Asseldonk, Edwin H.F.; Veneman, J.F.; Ekkelenkamp, R.; Buurke, Jaap; van der Helm, F.C.T.; van der Kooij, Herman

    2008-01-01

    “Assist as needed” control algorithms promote activity of patients during robotic gait training. Implementing these requires a free walking mode of a device, as unassisted motions should not be hindered. The goal of this study was to assess the normality of walking in the free walking mode of the

  8. Open Object Recognition for Humanoid Robots

    National Research Council Canada - National Science Library

    Fitzpatrick, Paul

    2003-01-01

    .... At the MIT Humanoid Robotics Group, investigators are developing methods that permit their robots to deduce the structure of novel activities, adopt the vocabulary appropriate for communication...

  9. Some possible applications of measurements on mu mesons to nuclear safeguards, nonproliferation, and arms control activities

    International Nuclear Information System (INIS)

    Kane, W.R.; Vanier, P.E.

    1997-01-01

    In the nuclear safeguards and arms control areas, well-developed methodologies exist for determining the properties of nuclear materials via measurements of the gamma rays and neutrons emitted from these materials, or in the arms control area, by the use of radiography. In certain favorable instances, it may by feasible to perform comparable measurements with the use of a ubiquitous, naturally-occurring radiation--cosmic ray mu mesons (muons). At the earth's surface these charged particles have a broad energy distribution peaking at about 500 MeV with a flux of approximately 10 -2 /cm 2 -sec-steradian. In traversing matter, muons lose energy at a rate of approximately 2 MeV/gram almost independent of atomic number. Muons can readily be detected by either plastic scintillators or wire planes. While the flux is small, a scintillator of one meter area, for example, will register about 20,000 events/min. these particles should have utility in the detection and imaging of objects with sectional densities of a few hundred grams/cm 2 . The degree of intrusiveness of the imaging can be controlled through the detector configuration. Some possible applications include: (1) mass measurements on large UF 6 cylinders, (2) determination of the size of treaty-limited objects, e.g., missiles, in rail cars or other containment; (3) verification of single or multiple warheads or components; (4) the detection of concealed, underground cavities. Examples will be presented

  10. Active Head Motion Compensation of TMS Robotic System Using Neuro-Fuzzy Estimation

    Directory of Open Access Journals (Sweden)

    Wan Zakaria W.N.

    2016-01-01

    Full Text Available Transcranial Magnetic Stimulation (TMS allows neuroscientist to study human brain behaviour and also become an important technique for changing the activity of brain neurons and the functions they sub serve. However, conventional manual procedure and robotized TMS are currently unable to precisely position the TMS coil because of unconstrained subject’s head movement and excessive contact force between the coil and subject’s head. This paper addressed this challenge by proposing an adaptive neuro-fuzzy force control to enable low contact force with a moving target surface. A learning and adaption mechanism is included in the control scheme to improve position disturbance estimation. The results show the ability of the proposed force control scheme to compensate subject’s head motions while maintaining desired contact force, thus allowing for more accurate and repeatable TMS procedures.

  11. Field dose radiation determination by active learning with Gaussian Process for autonomous robot guiding

    International Nuclear Information System (INIS)

    Freitas Naiff, Danilo de; Silveira, Paulo R.; Pereira, Claudio M.N.A.

    2017-01-01

    This article proposes an approach for determination of radiation dose pro le in a radiation-susceptible environment, aiming to guide an autonomous robot in acting on those environments, reducing the human exposure to dangerous amount of dose. The approach consists of an active learning method based on information entropy reduction, using log-normally warped Gaussian Process (GP) as surrogate model, resulting in non-linear online regression with sequential measurements. Experiments with simulated radiation dose fields of varying complexity were made, and results showed that the approach was effective in reconstruct the eld with high accuracy, through relatively few measurements. The technique was also shown some robustness in presence measurement noise, present in real measurements, by assuming Gaussian noise. (author)

  12. Field dose radiation determination by active learning with Gaussian Process for autonomous robot guiding

    Energy Technology Data Exchange (ETDEWEB)

    Freitas Naiff, Danilo de; Silveira, Paulo R.; Pereira, Claudio M.N.A., E-mail: danilonai1992@poli.ufrj.br, E-mail: paulo@lmp.ufrj.br, E-mail: cmnap@ien.gov.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil); Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-11-01

    This article proposes an approach for determination of radiation dose pro le in a radiation-susceptible environment, aiming to guide an autonomous robot in acting on those environments, reducing the human exposure to dangerous amount of dose. The approach consists of an active learning method based on information entropy reduction, using log-normally warped Gaussian Process (GP) as surrogate model, resulting in non-linear online regression with sequential measurements. Experiments with simulated radiation dose fields of varying complexity were made, and results showed that the approach was effective in reconstruct the eld with high accuracy, through relatively few measurements. The technique was also shown some robustness in presence measurement noise, present in real measurements, by assuming Gaussian noise. (author)

  13. Robotics in nuclear engineering. Computer-assisted teleoperation in hazardous environments with particular reference to radiation fields

    Energy Technology Data Exchange (ETDEWEB)

    Larcombe, M H.E.; Halsall, J R

    1984-01-01

    The subject is covered in chapters, entitled: foreword and definitions; introduction; robotics state of the art 1984; potential applications; advanced remote control; robot system design principles; robot system skills; planning of remote control robotics R and D; example systems; REMCON (advanced remote control robotic systems) guidelines; robot activation; robot instrumentation; robot guidance; design of equipment for robotic maintenance; ergonomics of control.

  14. Device for dynamic switching of robot control points

    DEFF Research Database (Denmark)

    2015-01-01

    The invention comprises a system for switching between control points of a robotic system involving an industrial robot including a robot arm with a number of joints and provided with a tool interest point movable in a plurality of degrees of freedom.......The invention comprises a system for switching between control points of a robotic system involving an industrial robot including a robot arm with a number of joints and provided with a tool interest point movable in a plurality of degrees of freedom....

  15. External Environment Sensing by a Module on Self-reconfiguration Robot

    Science.gov (United States)

    Goto, Tomotsugu; Uchida, Masafumi; Onogaki, Hitoshi

    In the situation in which a robot and a human work together by collaborating with each other, a robot and a human share one working environment, and each interferes in each other. The boundary of each complex dynamic occupation area changes in the connection movement which is the component of collaborative works at this time. The main restraint condition which relates to the robustness of that connection movement is each physical charactristics, that is, the embodiment. A robot body is variability though the embodiment of a human is almost fixed. Therefore, the safe and the robust connection movement is brought when a robot has the robot body which is well suitable for the embodiment of a human. A purpose for this research is that the colaboration works between the self-reconfiguration robot and a human is realized. To achieve this purpose, sensing function of external environment on a module was examined. A module is a component of the self-reconfiguration robot. A robot body vibrates when a module actuates an arm actively. This vibration is observed by using some acceleration sensors. Measured datas reflects a difference of objects that it touches a robot body. In this paper, the sensing technique of external environment which identifies this difference by using the neural network is proposed.

  16. Non-manufacturing applications of robotics; Applications non-manufacturieres de la robotique

    Energy Technology Data Exchange (ETDEWEB)

    Dauchez, P. [LIRMM, Laboratoire d' Informatique, de Robotique et de Microelectronique de Montpellier, 34 (France)

    2000-12-01

    This book presents the different non-manufacturing sectors of activity where robotics can have useful or necessary applications: underwater robotics, agriculture robotics, road work robotics, nuclear robotics, medical-surgery robotics, aids to disabled people, entertainment robotics. Service robotics has been voluntarily excluded because this developing sector is not mature yet. (J.S.)

  17. Task oriented evaluation system for maintenance robots

    International Nuclear Information System (INIS)

    Asame, Hajime; Endo, Isao; Kotosaka, Shin-ya; Takata, Shozo; Hiraoka, Hiroyuki; Kohda, Takehisa; Matsumoto, Akihiro; Yamagishi, Kiichiro.

    1994-01-01

    The adaptability evaluation of maintenance robots to autonomous plants has been discussed. In this paper, a new concept of autonomous plant with maintenance robots are introduced, and a framework of autonomous maintenance system is proposed. Then, task-oriented evaluation of robot arms is discussed for evaluating their adaptability to maintenance tasks, and a new criterion called operability is proposed for adaptability evaluation. The task-oriented evaluation system is implemented and applied to structural design of robot arms. Using genetic algorithm, an optimal structure adaptable to a pump disassembly task is obtained. (author)

  18. Controller design for Robotic hand through Electroencephalogram

    Directory of Open Access Journals (Sweden)

    Pandelidis P.

    2016-01-01

    Full Text Available - This paper deals with the designing, the construction and the control of a robotic hand via an electroencephalogram sensor. First a robotic device that is able to mimic a real human hand is constructed. A PID controller is designed in order to improve the performance of the robotic arm for grabbing objects. Furthermore, a novel design approach is presented for controlling the motion of the robotic arm using signals produced from an innovative electroencephalogram sensor that detects the concentration of the brain

  19. Robot engineering

    International Nuclear Information System (INIS)

    Jung, Seul

    2006-02-01

    This book deals with robot engineering, giving descriptions of robot's history, current tendency of robot field, work and characteristic of industrial robot, essential merit and vector, application of matrix, analysis of basic vector, expression of Denavit-Hartenberg, robot kinematics such as forward kinematics, inverse kinematics, cases of MATLAB program, and motion kinematics, robot kinetics like moment of inertia, centrifugal force and coriolis power, and Euler-Lagrangian equation course plan, SIMULINK position control of robots.

  20. Robot engineering

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Seul

    2006-02-15

    This book deals with robot engineering, giving descriptions of robot's history, current tendency of robot field, work and characteristic of industrial robot, essential merit and vector, application of matrix, analysis of basic vector, expression of Denavit-Hartenberg, robot kinematics such as forward kinematics, inverse kinematics, cases of MATLAB program, and motion kinematics, robot kinetics like moment of inertia, centrifugal force and coriolis power, and Euler-Lagrangian equation course plan, SIMULINK position control of robots.

  1. Kinematics and Workspace of a 4-DOF Hybrid Palletizing Robot

    Directory of Open Access Journals (Sweden)

    Yong Tao

    2014-06-01

    Full Text Available We presented the kinematical analysis of a 4-DOF hybrid palletizing robot. The palletizing robot structure was proposed and the arm model of the robot was presented. The kinematical analysis of the end robotic manipulator was given. As a result, the position, velocity, and acceleration curves as well as the maximum workspace were demonstrated by simulation in Matlab. This study would be useful for the kinematical characteristics of the 4-DOF palletizing robot in space.

  2. Actively Perceiving and Responsive Soft Robots Enabled by Self-Powered, Highly Extensible, and Highly Sensitive Triboelectric Proximity- and Pressure-Sensing Skins.

    Science.gov (United States)

    Lai, Ying-Chih; Deng, Jianan; Liu, Ruiyuan; Hsiao, Yung-Chi; Zhang, Steven L; Peng, Wenbo; Wu, Hsing-Mei; Wang, Xingfu; Wang, Zhong Lin

    2018-06-04

    Robots that can move, feel, and respond like organisms will bring revolutionary impact to today's technologies. Soft robots with organism-like adaptive bodies have shown great potential in vast robot-human and robot-environment applications. Developing skin-like sensory devices allows them to naturally sense and interact with environment. Also, it would be better if the capabilities to feel can be active, like real skin. However, challenges in the complicated structures, incompatible moduli, poor stretchability and sensitivity, large driving voltage, and power dissipation hinder applicability of conventional technologies. Here, various actively perceivable and responsive soft robots are enabled by self-powered active triboelectric robotic skins (tribo-skins) that simultaneously possess excellent stretchability and excellent sensitivity in the low-pressure regime. The tribo-skins can actively sense proximity, contact, and pressure to external stimuli via self-generating electricity. The driving energy comes from a natural triboelectrification effect involving the cooperation of contact electrification and electrostatic induction. The perfect integration of the tribo-skins and soft actuators enables soft robots to perform various actively sensing and interactive tasks including actively perceiving their muscle motions, working states, textile's dampness, and even subtle human physiological signals. Moreover, the self-generating signals can drive optoelectronic devices for visual communication and be processed for diverse sophisticated uses. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Humanlike robot hands controlled by brain activity arouse illusion of ownership in operators

    Science.gov (United States)

    Alimardani, Maryam; Nishio, Shuichi; Ishiguro, Hiroshi

    2013-08-01

    Operators of a pair of robotic hands report ownership for those hands when they hold image of a grasp motion and watch the robot perform it. We present a novel body ownership illusion that is induced by merely watching and controlling robot's motions through a brain machine interface. In past studies, body ownership illusions were induced by correlation of such sensory inputs as vision, touch and proprioception. However, in the presented illusion none of the mentioned sensations are integrated except vision. Our results show that during BMI-operation of robotic hands, the interaction between motor commands and visual feedback of the intended motions is adequate to incorporate the non-body limbs into one's own body. Our discussion focuses on the role of proprioceptive information in the mechanism of agency-driven illusions. We believe that our findings will contribute to improvement of tele-presence systems in which operators incorporate BMI-operated robots into their body representations.

  4. Contextual action recognition and target localization with an active allocation of attention on a humanoid robot

    International Nuclear Information System (INIS)

    Ognibene, Dimitri; Chinellato, Eris; Sarabia, Miguel; Demiris, Yiannis

    2013-01-01

    Exploratory gaze movements are fundamental for gathering the most relevant information regarding the partner during social interactions. Inspired by the cognitive mechanisms underlying human social behaviour, we have designed and implemented a system for a dynamic attention allocation which is able to actively control gaze movements during a visual action recognition task exploiting its own action execution predictions. Our humanoid robot is able, during the observation of a partner's reaching movement, to contextually estimate the goal position of the partner's hand and the location in space of the candidate targets. This is done while actively gazing around the environment, with the purpose of optimizing the gathering of information relevant for the task. Experimental results on a simulated environment show that active gaze control, based on the internal simulation of actions, provides a relevant advantage with respect to other action perception approaches, both in terms of estimation precision and of time required to recognize an action. Moreover, our model reproduces and extends some experimental results on human attention during an action perception. (paper)

  5. Active delivery of the anterior arm and incidence of second-degree perineal tears: a clinical practice evaluation.

    Science.gov (United States)

    Mottet, Nicolas; Bonneaud, Marine; Eckman-Lacroix, Astrid; Ramanah, Rajeev; Riethmuller, Didier

    2017-05-12

    Evaluate the feasibility of active delivery of the anterior arm during spontaneous delivery. This maneuver could decrease incidence of second-degree perineal tears because it reduces fetal biacromial diameter. An observational comparative prospective study was conducted at our teaching maternity from July 2012 to March 2013. The study included 199 nulliparous women ≥18 years, who met the following criteria: singleton pregnancy, vaginal delivery with occiput anterior presentation, on epidural analgesia, from 37 weeks of gestation onward. The distribution of rate and type of perineal tears were compared between two groups: a non-exposed group and a group exposed to the maneuver. A total of 101 patients were exposed to Couder's maneuver (CM) and 98 patients were not exposed. In the intervention group, 3 failures of the maneuver were reported. The maneuver was considered easy in 80% of cases, moderately easy in 12% and difficult in 8% of cases. There was a significant difference (p = 0.03) in the distribution of perineal tears between the two groups. There was a significant reduction (p tears in the patients exposed to CM. There was no significant difference in the rate of anterior perineal trauma between the exposed and non-exposed arms. CM in primiparous women at term is feasible with a low failure rate and influences the distribution of perineal tears by lowering second-degree perineal tears in a highly significant manner (p <0.01).

  6. Modelling of industrial robot in LabView Robotics

    Science.gov (United States)

    Banas, W.; Cwikła, G.; Foit, K.; Gwiazda, A.; Monica, Z.; Sekala, A.

    2017-08-01

    Currently can find many models of industrial systems including robots. These models differ from each other not only by the accuracy representation parameters, but the representation range. For example, CAD models describe the geometry of the robot and some even designate a mass parameters as mass, center of gravity, moment of inertia, etc. These models are used in the design of robotic lines and sockets. Also systems for off-line programming use these models and many of them can be exported to CAD. It is important to note that models for off-line programming describe not only the geometry but contain the information necessary to create a program for the robot. Exports from CAD to off-line programming system requires additional information. These models are used for static determination of reachability points, and testing collision. It’s enough to generate a program for the robot, and even check the interaction of elements of the production line, or robotic cell. Mathematical models allow robots to study the properties of kinematic and dynamic of robot movement. In these models the geometry is not so important, so are used only selected parameters such as the length of the robot arm, the center of gravity, moment of inertia. These parameters are introduced into the equations of motion of the robot and motion parameters are determined.

  7. A robotic system for automation of logistics functions on the Space Station

    Science.gov (United States)

    Martin, J. C.; Purves, R. B.; Hosier, R. N.; Krein, B. A.

    1988-01-01

    Spacecraft inventory management is currently performed by the crew and as systems become more complex, increased crew time will be required to perform routine logistics activities. If future spacecraft are to function effectively as research labs and production facilities, the efficient use of crew time as a limited resource for performing mission functions must be employed. The use of automation and robotics technology, such as automated warehouse and materials handling functions, can free the crew from many logistics tasks and provide more efficient use of crew time. Design criteria for a Space Station Automated Logistics Inventory Management System is focused on through the design and demonstration of a mobile two armed terrestrial robot. The system functionally represents a 0 gravity automated inventory management system and the problems associated with operating in such an environment. Features of the system include automated storage and retrieval, item recognition, two armed robotic manipulation, and software control of all inventory item transitions and queries.

  8. Robot-assisted automatic ultrasound calibration.

    Science.gov (United States)

    Aalamifar, Fereshteh; Cheng, Alexis; Kim, Younsu; Hu, Xiao; Zhang, Haichong K; Guo, Xiaoyu; Boctor, Emad M

    2016-10-01

    Ultrasound (US) calibration is the process of determining the unknown transformation from a coordinate frame such as the robot's tooltip to the US image frame and is a necessary task for any robotic or tracked US system. US calibration requires submillimeter-range accuracy for most applications, but it is a time-consuming and repetitive task. We provide a new framework for automatic US calibration with robot assistance and without the need for temporal calibration. US calibration based on active echo (AE) phantom was previously proposed, and its superiority over conventional cross-wire phantom-based calibration was shown. In this work, we use AE to guide the robotic arm motion through the process of data collection; we combine the capability of the AE point to localize itself in the frame of the US image with the automatic motion of the robotic arm to provide a framework for calibrating the arm to the US image automatically. We demonstrated the efficacy of the automated method compared to the manual method through experiments. To highlight the necessity of frequent ultrasound calibration, it is demonstrated that the calibration precision changed from 1.67 to 3.20 mm if the data collection is not repeated after a dismounting/mounting of the probe holder. In a large data set experiment, similar reconstruction precision of automatic and manual data collection was observed, while the time was reduced by 58 %. In addition, we compared ten automatic calibrations with ten manual ones, each performed in 15 min, and showed that all the automatic ones could converge in the case of setting the initial matrix as identity, while this was not achieved by manual data sets. Given the same initial matrix, the repeatability of the automatic was [0.46, 0.34, 0.80, 0.47] versus [0.42, 0.51, 0.98, 1.15] mm in the manual case for the US image four corners. The submillimeter accuracy requirement of US calibration makes frequent data collections unavoidable. We proposed an automated

  9. An expert system for automated robotic grasping

    International Nuclear Information System (INIS)

    Stansfield, S.A.

    1990-01-01

    Many US Department of Energy sites and facilities will be environmentally remediated during the next several decades. A number of the restoration activities (e.g., decontamination and decommissioning of inactive nuclear facilities) can only be carried out by remote means and will be manipulation-intensive tasks. Experience has shown that manipulation tasks are especially slow and fatiguing for the human operator of a remote manipulator. In this paper, the authors present a rule-based expert system for automated, dextrous robotic grasping. This system interprets the features of an object to generate hand shaping and wrist orientation for a robot hand and arm. The system can be used in several different ways to lessen the demands on the human operator of a remote manipulation system - either as a fully autonomous grasping system or one that generates grasping options for a human operator and then automatically carries out the selected option

  10. Robotized transcranial magnetic stimulation

    CERN Document Server

    Richter, Lars

    2014-01-01

    Presents new, cutting-edge algorithms for robot/camera calibration, sensor fusion and sensor calibration Explores the main challenges for accurate coil positioning, such as head motion, and outlines how active robotic motion compensation can outperform hand-held solutions Analyzes how a robotized system in medicine can alleviate concerns with a patient's safety, and presents a novel fault-tolerant algorithm (FTA) sensor for system safety

  11. Simulation of robot manipulators

    International Nuclear Information System (INIS)

    Kress, R.L.; Babcock, S.M.; Bills, K.C.; Kwon, D.S.; Schoenwald, D.A.

    1995-01-01

    This paper describes Oak Ridge National Laboratory's development of an environment for the simulation of robotic manipulators. Simulation includes the modeling of kinematics, dynamics, sensors, actuators, control systems, operators, and environments. Models will be used for manipulator design, proposal evaluation, control system design and analysis, graphical preview of proposed motions, safety system development, and training. Of particular interest is the development of models for robotic manipulators having at least one flexible link. As a first application, models have been developed for the Pacific Northwest Laboratories' Flexible Beam Testbed which is a one-Degree-Of-Freedom, flexible arm with a hydraulic base actuator. Initial results show good agreement between model and experiment

  12. Human - Robot Proximity

    DEFF Research Database (Denmark)

    Nickelsen, Niels Christian Mossfeldt

    The media and political/managerial levels focus on the opportunities to re-perform Denmark through digitization. Feeding assistive robotics is a welfare technology, relevant to citizens with low or no function in their arms. Despite national dissemination strategies, it proves difficult to recruit...... the study that took place as multi-sited ethnography at different locations in Denmark and Sweden. Based on desk research, observation of meals and interviews I examine socio-technological imaginaries and their practical implications. Human - robotics interaction demands engagement and understanding...

  13. Validation of a motor activity system by a robotically controlled vehicle and using standard reference compounds.

    Science.gov (United States)

    Patterson, John P; Markgraf, Carrie G; Cirino, Maria; Bass, Alan S

    2005-01-01

    A series of experiments were undertaken to evaluate the accuracy, precision, specificity, and sensitivity of an automated, infrared photo beam-based open field motor activity system, the MotorMonitor v. 4.01, Hamilton-Kinder, LLC, for use in a good laboratory practices (GLP) Safety Pharmacology laboratory. This evaluation consisted of two phases: (1) system validation, employing known inputs using the EM-100 Controller Photo Beam Validation System, a robotically controlled vehicle representing a rodent and (2) biologic validation, employing groups of rats treated with the standard pharmacologic agents diazepam or D-amphetamine. The MotorMonitor's parameters that described the open-field activity of a subject were: basic movements, total distance, fine movements, x/y horizontal ambulations, rearing, and total rest time. These measurements were evaluated over a number of zones within each enclosure. System validation with the EM-100 Controller Photo Beam Validation System showed that all the parameters accurately and precisely measured what they were intended to measure, with the exception of fine movements and x/y ambulations. Biologic validation using the central nervous system depressant diazepam at 1, 2, or 5 mg/kg, i.p. produced the expected dose-dependent reduction in rat motor activity. In contrast, the central nervous system stimulant D-amphetamine produced the expected increases in rat motor activity at 0.1 and 1 mg/kg, i.p, demonstrating the specificity and sensitivity of the system. Taken together, these studies of the accuracy, precision, specificity, and sensitivity show the importance of both system and biologic validation in the evaluation of an automated open field motor activity system for use in a GLP compliant laboratory.

  14. Robotic fabrication in architecture, art, and design

    CERN Document Server

    Braumann, Johannes

    2013-01-01

    Architects, artists, and designers have been fascinated by robots for many decades, from Villemard’s utopian vision of an architect building a house with robotic labor in 1910, to the design of buildings that are robots themselves, such as Archigram’s Walking City. Today, they are again approaching the topic of robotic fabrication but this time employing a different strategy: instead of utopian proposals like Archigram’s or the highly specialized robots that were used by Japan’s construction industry in the 1990s, the current focus of architectural robotics is on industrial robots. These robotic arms have six degrees of freedom and are widely used in industry, especially for automotive production lines. What makes robotic arms so interesting for the creative industry is their multi-functionality: instead of having to develop specialized machines, a multifunctional robot arm can be equipped with a wide range of end-effectors, similar to a human hand using various tools. Therefore, architectural researc...

  15. Study Of Robotic Replacement Of Equipment Modules

    Science.gov (United States)

    Backes, Paul G.; Tso, Kam S.

    1992-01-01

    Report discusses issues pertaining to control of single-arm robotic manipulator to remove and install interchangeable equipment modules. Presents preliminary control strategy intended to guide development of control algorithms, along with analyses of problems arising in implementing strategy.

  16. Star Formation Activity Beyond the Outer Arm. I. WISE -selected Candidate Star-forming Regions

    Energy Technology Data Exchange (ETDEWEB)

    Izumi, Natsuko; Yasui, Chikako; Saito, Masao [National Astronomical Observatory of Japan, 2-21-1, Osawa, Mitaka, Tokyo 181-8588 (Japan); Kobayashi, Naoto; Hamano, Satoshi, E-mail: natsuko.izumi@nao.ac.jp [Laboratory of Infrared High-resolution spectroscopy (LIH), Koyama Astronomical Observatory, Kyoto Sangyo University, Motoyama, Kamigamo, Kita-ku, Kyoto 603-8555 (Japan)

    2017-10-01

    The outer Galaxy beyond the Outer Arm provides a good opportunity to study star formation in an environment significantly different from that in the solar neighborhood. However, star-forming regions in the outer Galaxy have never been comprehensively studied or cataloged because of the difficulties in detecting them at such large distances. We studied 33 known young star-forming regions associated with 13 molecular clouds at R {sub G} ≥ 13.5 kpc in the outer Galaxy with data from the Wide-field Infrared Survey Explorer ( WISE ) mid-infrared all-sky survey. From their color distribution, we developed a simple identification criterion of star-forming regions in the outer Galaxy with the WISE color. We applied the criterion to all the WISE sources in the molecular clouds in the outer Galaxy at R {sub G} ≥ 13.5 kpc detected with the Five College Radio Astronomy Observatory (FCRAO) {sup 12}CO survey of the outer Galaxy, of which the survey region is 102.°49 ≤  l  ≤ 141.°54, −3.°03 ≤  b  ≤ 5.°41, and successfully identified 711 new candidate star-forming regions in 240 molecular clouds. The large number of samples enables us to perform the statistical study of star formation properties in the outer Galaxy for the first time. This study is crucial to investigate the fundamental star formation properties, including star formation rate, star formation efficiency, and initial mass function, in a primordial environment such as the early phase of the Galaxy formation.

  17. Observation and imitation of actions performed by humans, androids, and robots: an EMG study

    Science.gov (United States)

    Hofree, Galit; Urgen, Burcu A.; Winkielman, Piotr; Saygin, Ayse P.

    2015-01-01

    Understanding others’ actions is essential for functioning in the physical and social world. In the past two decades research has shown that action perception involves the motor system, supporting theories that we understand others’ behavior via embodied motor simulation. Recently, empirical approach to action perception has been facilitated by using well-controlled artificial stimuli, such as robots. One broad question this approach can address is what aspects of similarity between the observer and the observed agent facilitate motor simulation. Since humans have evolved among other humans and animals, using artificial stimuli such as robots allows us to probe whether our social perceptual systems are specifically tuned to process other biological entities. In this study, we used humanoid robots with different degrees of human-likeness in appearance and motion along with electromyography (EMG) to measure muscle activity in participants’ arms while they either observed or imitated videos of three agents produce actions with their right arm. The agents were a Human (biological appearance and motion), a Robot (mechanical appearance and motion), and an Android (biological appearance and mechanical motion). Right arm muscle activity increased when participants imitated all agents. Increased muscle activation was found also in the stationary arm both during imitation and observation. Furthermore, muscle activity was sensitive to motion dynamics: activity was significantly stronger for imitation of the human than both mechanical agents. There was also a relationship between the dynamics of the muscle activity and motion dynamics in stimuli. Overall our data indicate that motor simulation is not limited to observation and imitation of agents with a biological appearance, but is also found for robots. However we also found sensitivity to human motion in the EMG responses. Combining data from multiple methods allows us to obtain a more complete picture of action

  18. Observation and Imitation of Actions Performed by Humans, Androids and Robots: An EMG study

    Directory of Open Access Journals (Sweden)

    Galit eHofree

    2015-06-01

    Full Text Available Understanding others’ actions is essential for functioning in the physical and social world. In the past two decades research has shown that action perception involves the motor system, supporting theories that we understand others’ behavior via embodied motor simulation. Recently, action perception has been facilitated by using well-controlled artificial stimuli, such as robots. One key question this approach enables is what aspects of similarity between the observer and the observed agent facilitate motor simulation? Since humans have evolved among other humans and animals, using artificial stimuli such as robots allows us to probe whether our social perceptual systems are tuned to process other biological entities. In this study, we used humanoid robots with different degrees of humanlikeness in appearance and motion along with electromyography (EMG to measure muscle activity in participants’ arms while they either observed or imitated videos of three agents produce actions with their right arm. The agents were a Human (biological appearance and motion, a Robot (mechanical appearance and motion and an Android (biological appearance, mechanical motion. Right arm muscle activity increased when participants imitated all agents. Increased muscle activation was found also in the stationary arm both during imitation and observation. Furthermore, muscle activity was sensitive to motion dynamics: activity was significantly stronger for imitation of the human than both mechanical agents. There was also a relationship between the dynamics of the muscle activity and motion dynamics in stimuli. Overall our data indicate that motor simulation is not limited to observation and imitation of agents with a biological appearance, but is also found for robots. However we also found sensitivity to human motion in the EMG responses. Combining data from multiple methods allows us to obtain a more complete picture of action understanding and the underlying

  19. The Influence of Robotic Assistance on Reducing Neuromuscular Effort and Fatigue during Extravehicular Activity Glove Use

    Science.gov (United States)

    Madden, Kaci E.; Deshpande, Ashish D.; Peters, Benjamin J.; Rogers, Jonathan M.; Laske, Evan A.; McBryan, Emily R.

    2017-01-01

    The three-layered, pressurized space suit glove worn by Extravehicular Activity (EVA) crew members during missions commonly causes hand and forearm fatigue. The Spacesuit RoboGlove (SSRG), a Phase VI EVA space suit glove modified with robotic grasp-assist capabilities, has been developed to augment grip strength in order to improve endurance and reduce the risk of injury in astronauts. The overall goals of this study were to i) quantify the neuromuscular modulations that occur in response to wearing a conventional Phase VI space suit glove (SSG) during a fatiguing task, and ii) determine the efficacy of Spacesuit RoboGlove (SSRG) in reversing the adverse neuromuscular modulations and restoring altered muscular activity to barehanded levels. Six subjects performed a fatigue sequence consisting of repetitive dynamic-gripping interspersed with isometric grip-holds under three conditions: barehanded, wearing pressurized SSG, and wearing pressurized SSRG. Surface electromyography (sEMG) from six forearm muscles (flexor digitorum superficialis (FDS), flexor carpi radialis (FCR), flexor carpi ulnaris (FCU), extensor digitorum (ED), extensor carpi radialis longus (ECRL), and extensor carpi ulnaris (ECU)) and subjective fatigue ratings were collected during each condition. Trends in amplitude and spectral distributions of the sEMG signals were used to derive metrics quantifying neuromuscular effort and fatigue that were compared across the glove conditions. Results showed that by augmenting finger flexion, the SSRG successfully reduced the neuromuscular effort needed to close the fingers of the space suit glove in more than half of subjects during two types of tasks. However, the SSRG required more neuromuscular effort to extend the fingers compared to a conventional SSG in many subjects. Psychologically, the SSRG aided subjects in feeling less fatigued during short periods of intense work compared to the SSG. The results of this study reveal the promise of the SSRG as a

  20. Optimization approaches for robot trajectory planning

    Directory of Open Access Journals (Sweden)

    Carlos Llopis-Albert

    2018-03-01

    Full Text Available The development of optimal trajectory planning algorithms for autonomous robots is a key issue in order to efficiently perform the robot tasks. This problem is hampered by the complex environment regarding the kinematics and dynamics of robots with several arms and/or degrees of freedom (dof, the design of collision-free trajectories and the physical limitations of the robots. This paper presents a review about the existing robot motion planning techniques and discusses their pros and cons regarding completeness, optimality, efficiency, accuracy, smoothness, stability, safety and scalability.