WorldWideScience

Sample records for robot-assisted reaching exercise

  1. Analysis of reaching movements of upper arm in robot assisted exercises. Kinematic assessment of robot assisted upper arm reaching single-joint movements.

    Science.gov (United States)

    Iuppariello, Luigi; D'Addio, Giovanni; Romano, Maria; Bifulco, Paolo; Lanzillo, Bernardo; Pappone, Nicola; Cesarelli, Mario

    2016-01-01

    Robot-mediated therapy (RMT) has been a very dynamic area of research in recent years. Robotics devices are in fact capable to quantify the performances of a rehabilitation task in treatments of several disorders of the arm and the shoulder of various central and peripheral etiology. Different systems for robot-aided neuro-rehabilitation are available for upper limb rehabilitation but the biomechanical parameters proposed until today, to evaluate the quality of the movement, are related to the specific robot used and to the type of exercise performed. Besides, none study indicated a standardized quantitative evaluation of robot assisted upper arm reaching movements, so the RMT is still far to be considered a standardised tool. In this paper a quantitative kinematic assessment of robot assisted upper arm reaching movements, considering also the effect of gravity on the quality of the movements, is proposed. We studied a group of 10 healthy subjects and results indicate that our advised protocol can be useful for characterising normal pattern in reaching movements.

  2. Robot-assisted reaching exercise promotes arm movement recovery in chronic hemiparetic stroke: a randomized controlled pilot study

    Directory of Open Access Journals (Sweden)

    Rymer W Zev

    2006-06-01

    Full Text Available Abstract Background and purpose Providing active assistance to complete desired arm movements is a common technique in upper extremity rehabilitation after stroke. Such active assistance may improve recovery by affecting somatosensory input, motor planning, spasticity or soft tissue properties, but it is labor intensive and has not been validated in controlled trials. The purpose of this study was to investigate the effects of robotically administered active-assistive exercise and compare those with free reaching voluntary exercise in improving arm movement ability after chronic stroke. Methods Nineteen individuals at least one year post-stroke were randomized into one of two groups. One group performed 24 sessions of active-assistive reaching exercise with a simple robotic device, while a second group performed a task-matched amount of unassisted reaching. The main outcome measures were range and speed of supported arm movement, range, straightness and smoothness of unsupported reaching, and the Rancho Los Amigos Functional Test of Upper Extremity Function. Results and discussion There were significant improvements with training for range of motion and velocity of supported reaching, straightness of unsupported reaching, and functional movement ability. These improvements were not significantly different between the two training groups. The group that performed unassisted reaching exercise improved the smoothness of their reaching movements more than the robot-assisted group. Conclusion Improvements with both forms of exercise confirmed that repeated, task-related voluntary activation of the damaged motor system is a key stimulus to motor recovery following chronic stroke. Robotically assisting in reaching successfully improved arm movement ability, although it did not provide any detectable, additional value beyond the movement practice that occurred concurrently with it. The inability to detect any additional value of robot-assisted reaching

  3. Ability to Reach Orgasm in Patients with Prostate Cancer Treated with Robot-assisted Laparoscopic Prostatectomy

    DEFF Research Database (Denmark)

    Østby-Deglum, Marie; Axcrona, K; Brennhovd, B.

    2016-01-01

    Objectives To study the ability to reach orgasm after robot-assisted laparoscopic prostatectomy (RALP) in relation to demographic, cancer-related, and surgical variables, and the use of erectile aids. Methods In this cross-sectional study at a mean of 3 years after RALP at Oslo University Hospital......, 982 men were invited to complete a mailed questionnaire, and 777 responded. Respondents who reported postoperative radiotherapy or hormone treatment, or did not report on orgasm were omitted, leaving 609 patients for analysis. Ability to reach orgasm was rated on 1 question from The Expanded Prostate...... Cancer Index Composite 26-item version, and dichotomized into "good" or "poor." Results Overall, 27% of the men reported good ability to reach orgasm: 22% among those did not use erectile aids and 34% among those did (P =.001). Univariate analysis of men with good versus poor ability to reach orgasm...

  4. Ability to Reach Orgasm in Patients With Prostate Cancer Treated With Robot-assisted Laparoscopic Prostatectomy.

    Science.gov (United States)

    Østby-Deglum, Marie; Axcrona, Karol; Brennhovd, Bjørn; Dahl, Alv A

    2016-06-01

    To study the ability to reach orgasm after robot-assisted laparoscopic prostatectomy (RALP) in relation to demographic, cancer-related, and surgical variables, and the use of erectile aids. In this cross-sectional study at a mean of 3 years after RALP at Oslo University Hospital, 982 men were invited to complete a mailed questionnaire, and 777 responded. Respondents who reported postoperative radiotherapy or hormone treatment, or did not report on orgasm were omitted, leaving 609 patients for analysis. Ability to reach orgasm was rated on 1 question from The Expanded Prostate Cancer Index Composite 26-item version, and dichotomized into "good" or "poor." Overall, 27% of the men reported good ability to reach orgasm: 22% among those did not use erectile aids and 34% among those did (P = .001). Univariate analysis of men with good versus poor ability to reach orgasm showed many significant differences. In multivariate analysis, being older, having a reduced physical quality of life, and erectile dysfunction were significantly associated with poor ability to reach orgasm. Erectile dysfunction showed an odds ratio of 4.86 for poor orgasmic ability. The 48% of men who used erectile aids had significantly better orgasmic ability than the nonusers. In our sample, 27% had good ability to reach orgasm at a mean of 3 years after RALP. Poor orgasmic ability was associated with being older, poor erectile function, and a reduced physical quality of life. Using erectile aids increased the rate of good ability to reach orgasm. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Feedback-controlled robotics-assisted treadmill exercise to assess and influence aerobic capacity early after stroke: a proof-of-concept study.

    Science.gov (United States)

    Stoller, Oliver; Schindelholz, Matthias; Bichsel, Lukas; Schuster, Corina; de Bie, Rob A; de Bruin, Eling D; Hunt, Kenneth J

    2014-07-01

    The majority of post-stroke individuals suffer from low exercise capacity as a secondary reaction to immobility. The aim of this study was to prove the concept of feedback-controlled robotics-assisted treadmill exercise (RATE) to assess aerobic capacity and guide cardiovascular exercise in severely impaired individuals early after stroke. Subjects underwent constant load and incremental exercise testing using a human-in-the-loop feedback system within a robotics-assisted exoskeleton (Lokomat, Hocoma AG, CH). Inclusion criteria were: stroke onset ≤8 weeks, stable medical condition, non-ambulatory status, moderate motor control of the lower limbs and appropriate cognitive function. Outcome measures included oxygen uptake kinetics, peak oxygen uptake (VO2peak), gas exchange threshold (GET), peak heart rate (HRpeak), peak work rate (Ppeak) and accuracy of reaching target work rate (P-RMSE). Three subjects (18-42 d post-stroke) were included. Oxygen uptake kinetics during constant load ranged from 42.0 to 60.2 s. Incremental exercise testing showed: VO2peak range 19.7-28.8 ml/min/kg, GET range 11.6-12.7 ml/min/kg, and HRpeak range 115-161 bpm. Ppeak range was 55.2-110.9 W and P-RMSE range was 3.8-7.5 W. The concept of feedback-controlled RATE for assessment of aerobic capacity and guidance of cardiovascular exercise is feasible. Further research is warranted to validate the method on a larger scale. Aerobic capacity is seriously reduced in post-stroke individuals as a secondary reaction to immobility. Robotics-assisted walking devices may have substantial clinical relevance regarding assessment and improvement of aerobic capacity early after stroke. Feedback-controlled robotics-assisted treadmill exercise represents a new concept for cardiovascular assessment and intervention protocols for severely impaired individuals.

  6. Cardiovascular rehabilitation soon after stroke using feedback-controlled robotics-assisted treadmill exercise: study protocol of a randomised controlled pilot trial.

    Science.gov (United States)

    Stoller, Oliver; de Bruin, Eling D; Schuster-Amft, Corina; Schindelholz, Matthias; de Bie, Rob A; Hunt, Kenneth J

    2013-09-22

    After experiencing a stroke, most individuals also suffer from cardiac disease, are immobile and thus have low endurance for exercise. Aerobic capacity is seriously reduced in these individuals and does not reach reasonable levels after conventional rehabilitation programmes. Cardiovascular exercise is beneficial for improvement of aerobic capacity in mild to moderate stroke. However, less is known about its impact on aerobic capacity, motor recovery, and quality-of-life in severely impaired individuals. The aim of this pilot study is to explore the clinical efficacy and feasibility of cardiovascular exercise with regard to aerobic capacity, motor recovery, and quality-of-life using feedback-controlled robotics-assisted treadmill exercise in non-ambulatory individuals soon after experiencing a stroke. This will be a single-centred single blind, randomised control trial with a pre-post intervention design. Subjects will be recruited early after their first stroke (≤20 weeks) at a neurological rehabilitation clinic and will be randomly allocated to an inpatient cardiovascular exercise programme that uses feedback-controlled robotics-assisted treadmill exercise (experimental) or to conventional robotics-assisted treadmill exercise (control). Intervention duration depends on the duration of each subject's inpatient rehabilitation period. Aerobic capacity, as the primary outcome measure, will be assessed using feedback-controlled robotics-assisted treadmill-based cardiopulmonary exercise testing. Secondary outcome measures will include gait speed, walking endurance, standing function, and quality-of-life. Outcome assessment will be conducted at baseline, after each 4-week intervention period, and before clinical discharge. Ethical approval has been obtained. Whether cardiovascular exercise in non-ambulatory individuals early after stroke has an impact on aerobic capacity, motor recovery, and quality-of-life is not yet known. Feedback-controlled robotics-assisted

  7. Feasibility of cardiopulmonary exercise testing and training using a robotics-assisted tilt table in dependent-ambulatory stroke patients.

    Science.gov (United States)

    Saengsuwan, Jittima; Huber, Celine; Schreiber, Jonathan; Schuster-Amft, Corina; Nef, Tobias; Hunt, Kenneth J

    2015-09-26

    We evaluated the feasibility of an augmented robotics-assisted tilt table (RATT) for incremental cardiopulmonary exercise testing (CPET) and exercise training in dependent-ambulatory stroke patients. Stroke patients (Functional Ambulation Category ≤ 3) underwent familiarization, an incremental exercise test (IET) and a constant load test (CLT) on separate days. A RATT equipped with force sensors in the thigh cuffs, a work rate estimation algorithm and real-time visual feedback to guide the exercise work rate was used. Feasibility assessment considered technical feasibility, patient tolerability, and cardiopulmonary responsiveness. Eight patients (4 female) aged 58.3 ± 9.2 years (mean ± SD) were recruited and all completed the study. For IETs, peak oxygen uptake (V'O2peak), peak heart rate (HRpeak) and peak work rate (WRpeak) were 11.9 ± 4.0 ml/kg/min (45 % of predicted V'O2max), 117 ± 32 beats/min (72 % of predicted HRmax) and 22.5 ± 13.0 W, respectively. Peak ratings of perceived exertion (RPE) were on the range "hard" to "very hard". All 8 patients reached their limit of functional capacity in terms of either their cardiopulmonary or neuromuscular performance. A ventilatory threshold (VT) was identified in 7 patients and a respiratory compensation point (RCP) in 6 patients: mean V'O2 at VT and RCP was 8.9 and 10.7 ml/kg/min, respectively, which represent 75 % (VT) and 85 % (RCP) of mean V'O2peak. Incremental CPET provided sufficient information to satisfy the responsiveness criteria and identification of key outcomes in all 8 patients. For CLTs, mean steady-state V'O2 was 6.9 ml/kg/min (49 % of V'O2 reserve), mean HR was 90 beats/min (56 % of HRmax), RPEs were > 2, and all patients maintained the active work rate for 10 min: these values meet recommended intensity levels for bouts of training. The augmented RATT is deemed feasible for incremental cardiopulmonary exercise testing and exercise training in dependent

  8. Validation of a mechanism to balance exercise difficulty in robot-assisted upper-extremity rehabilitation after stroke

    Directory of Open Access Journals (Sweden)

    Zimmerli Lukas

    2012-02-01

    Full Text Available Abstract Background The motivation of patients during robot-assisted rehabilitation after neurological disorders that lead to impairments of motor functions is of great importance. Due to the increasing number of patients, increasing medical costs and limited therapeutic resources, clinicians in the future may want patients to practice their movements at home or with reduced supervision during their stay in the clinic. Since people only engage in an activity and are motivated to practice if the outcome matches the effort at which they perform, an augmented feedback application for rehabilitation should take the cognitive and physical deficits of patients into account and incorporate a mechanism that is capable of balancing i.e. adjusting the difficulty of an exercise in an augmented feedback application to the patient's capabilities. Methods We propose a computational mechanism based on Fitts' Law that balances i.e. adjusts the difficulty of an exercise for upper-extremity rehabilitation. The proposed mechanism was implemented into an augmented feedback application consisting of three difficulty conditions (easy, balanced, hard. The task of the exercise was to reach random targets on the screen from a starting point within a specified time window. The available time was decreased with increasing condition difficulty. Ten subacute stroke patients were recruited to validate the mechanism through a study. Cognitive and motor functions of patients were assessed using the upper extremity section of the Fugl-Meyer Assessment, the modified Ashworth scale as well as the Addenbrookes cognitive examination-revised. Handedness of patients was obtained using the Edinburgh handedness inventory. Patients' performance during the execution of the exercises was measured twice, once for the paretic and once for the non-paretic arm. Results were compared using a two-way ANOVA. Post hoc analysis was performed using a Tukey HSD with a significance level of p Results

  9. Work-rate-guided exercise testing in patients with incomplete spinal cord injury using a robotics-assisted tilt-table.

    Science.gov (United States)

    Laubacher, Marco; Perret, Claudio; Hunt, Kenneth J

    2015-01-01

    Robotics-assisted tilt-table (RTT) technology allows neurological rehabilitation therapy to be started early thus alleviating some secondary complications of prolonged bed rest. This study assessed the feasibility of a novel work-rate-guided RTT approach for cardiopulmonary training and assessment in patients with incomplete spinal cord injury (iSCI). Three representative subjects with iSCI at three distinct stages of primary rehabilitation completed an incremental exercise test (IET) and a constant load test (CLT) on a RTT augmented with integrated leg-force and position measurement and visual work rate feedback. Feasibility assessment focused on: (i) implementation, (ii) limited efficacy testing, (iii) acceptability. (i) All subjects were able follow the work rate target profile by adapting their volitional leg effort. (ii) During the IETs, peak oxygen uptake above rest was 304, 467 and 1378 ml/min and peak heart rate (HR) was 46, 32 and 65 beats/min above rest (subjects A, B and C, respectively). During the CLTs, steady-state oxygen uptake increased by 42%, 38% and 162% and HR by 12%, 20% and 29%. (iii) All exercise tests were tolerated well. The novel work-rate guided RTT intervention is deemed feasible for cardiopulmonary training and assessment in patients with iSCI: substantial cardiopulmonary responses were observed and the approach was found to be tolerable and implementable. Implications for Rehabilitation Work-rate guided robotics-assisted tilt-table technology is deemed feasible for cardiopulmonary assessment and training in patients with incomplete spinal cord injury. Robotics-assisted tilt-tables might be a good way to start with an active rehabilitation as early as possible after a spinal cord injury. During training with robotics-assisted devices the active participation of the patients is crucial to strain the cardiopulmonary system and hence gain from the training.

  10. Robot-Assisted End-Effector-Based Stair Climbing for Cardiopulmonary Exercise Testing: Feasibility, Reliability, and Repeatability.

    Science.gov (United States)

    Stoller, Oliver; Schindelholz, Matthias; Hunt, Kenneth J

    2016-01-01

    Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET) and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-controlled robot-assisted end-effector-based stair climbing (RASC). The aim of this study was to evaluate the feasibility, reliability, and repeatability of augmented RASC-based CPET in able-bodied subjects, with a view towards future research and applications in neurologically impaired populations. Twenty able-bodied subjects performed a familiarisation session and 2 consecutive incremental CPETs using augmented RASC. Outcome measures focussed on standard cardiopulmonary performance parameters and on accuracy of work rate tracking (RMSEP-root mean square error). Criteria for feasibility were cardiopulmonary responsiveness and technical implementation. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean differences, limits of agreement, and coefficients of variation (CoV) were estimated to assess repeatability. All criteria for feasibility were achieved. Mean V'O2peak was 106±9% of predicted V'O2max and mean HRpeak was 99±3% of predicted HRmax. 95% of the subjects achieved at least 1 criterion for V'O2max, and the detection of the sub-maximal ventilatory thresholds was successful (ventilatory anaerobic threshold 100%, respiratory compensation point 90% of the subjects). Excellent reliability was found for peak cardiopulmonary outcome measures (ICC ≥ 0.890, SEM ≤ 0.60%, MDC ≤ 1.67%). Repeatability for the primary outcomes was good (CoV ≤ 0.12). RASC-based CPET with feedback-guided exercise intensity demonstrated comparable or higher peak cardiopulmonary performance variables relative to predicted values, achieved the criteria for V'O2max

  11. Robot-Assisted End-Effector-Based Stair Climbing for Cardiopulmonary Exercise Testing: Feasibility, Reliability, and Repeatability.

    Directory of Open Access Journals (Sweden)

    Oliver Stoller

    Full Text Available Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-controlled robot-assisted end-effector-based stair climbing (RASC. The aim of this study was to evaluate the feasibility, reliability, and repeatability of augmented RASC-based CPET in able-bodied subjects, with a view towards future research and applications in neurologically impaired populations.Twenty able-bodied subjects performed a familiarisation session and 2 consecutive incremental CPETs using augmented RASC. Outcome measures focussed on standard cardiopulmonary performance parameters and on accuracy of work rate tracking (RMSEP-root mean square error. Criteria for feasibility were cardiopulmonary responsiveness and technical implementation. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC, standard error of the measurement (SEM, and minimal detectable change (MDC. Mean differences, limits of agreement, and coefficients of variation (CoV were estimated to assess repeatability.All criteria for feasibility were achieved. Mean V'O2peak was 106±9% of predicted V'O2max and mean HRpeak was 99±3% of predicted HRmax. 95% of the subjects achieved at least 1 criterion for V'O2max, and the detection of the sub-maximal ventilatory thresholds was successful (ventilatory anaerobic threshold 100%, respiratory compensation point 90% of the subjects. Excellent reliability was found for peak cardiopulmonary outcome measures (ICC ≥ 0.890, SEM ≤ 0.60%, MDC ≤ 1.67%. Repeatability for the primary outcomes was good (CoV ≤ 0.12.RASC-based CPET with feedback-guided exercise intensity demonstrated comparable or higher peak cardiopulmonary performance variables relative to predicted values, achieved the criteria for V'O2

  12. Efficacy of Feedback-Controlled Robotics-Assisted Treadmill Exercise to Improve Cardiovascular Fitness Early After Stroke: A Randomized Controlled Pilot Trial.

    Science.gov (United States)

    Stoller, Oliver; de Bruin, Eling D; Schindelholz, Matthias; Schuster-Amft, Corina; de Bie, Rob A; Hunt, Kenneth J

    2015-07-01

    Cardiovascular fitness is greatly reduced after stroke. Although individuals with mild to moderate impairments benefit from conventional cardiovascular exercise interventions, there is a lack of effective approaches for persons with severely impaired physical function. This randomized controlled pilot trial investigated efficacy and feasibility of feedback-controlled robotics-assisted treadmill exercise (FC-RATE) for cardiovascular rehabilitation in persons with severe impairments early after stroke. Twenty individuals (age 61 ± 11 years; 52 ± 31 days poststroke) with severe motor limitations (Functional Ambulation Classification 0-2) were recruited for FC-RATE or conventional robotics-assisted treadmill exercise (RATE) (4 weeks, 3 × 30-minute sessions/wk). Outcome measures focused on peak cardiopulmonary performance parameters, training intensity, and feasibility, with examiners blinded to allocation. All 14 allocated participants (70% of recruited) completed the intervention (7/group, withdrawals unrelated to intervention), without serious adverse events occurring. Cardiovascular fitness increased significantly in both groups, with peak oxygen uptake increasing from 14.6 to 17.7 mL · kg · min (+17.8%) after 4 weeks (45.8%-55.7% of predicted maximal aerobic capacity; time effect P = 0.01; no group-time interaction). Training intensity (% heart rate reserve) was significantly higher for FC-RATE (40% ± 3%) than for conventional RATE (14% ± 2%) (P = 0.001). Substantive overall increases in the main cardiopulmonary performance parameters were observed, but there were no significant between-group differences when comparing FC-RATE and conventional RATE. Feedback-controlled robotics-assisted treadmill exercise significantly increased exercise intensity, but recommended intensity levels for cardiovascular training were not consistently achieved. Future research should focus on appropriate algorithms within advanced robotic systems to promote optimal cardiovascular

  13. A pilot study of robotic-assisted exercise for hand weakness after stroke.

    Science.gov (United States)

    Stein, Joel; Bishop, Joel; Gillen, Glen; Helbok, Raimund

    2011-01-01

    Upper limb paresis is a major source of disability in stroke survivors, and robotic aided exercise therapy is a promising approach to enhance motor abilities. Few devices have been available to provide robotic therapy to the fingers and hand. We report an open-label pilot study of 12 individuals with chronic moderate hemiparesis after stroke who underwent a six-week training program using a hand robotic device. Participants received a total of 18 hours of robotic therapy. Improvements were found in multiple measures of motor performance, including the Upper Extremity Fugl-Meyer, the Motor Activity Log, the Manual Ability Measure-36, and the Jebsen Hand Function Test. All subjects tolerated the treatment well and no complications were observed. We conclude that robotic therapy for hand paresis after stroke is safe and feasible, and that further studies of efficacy are justified by these preliminary results. © 2011 IEEE

  14. Sequencing bilateral robot-assisted arm therapy and constraint-induced therapy improves reach to press and trunk kinematics in patients with stroke.

    Science.gov (United States)

    Hsieh, Yu-wei; Liing, Rong-jiuan; Lin, Keh-chung; Wu, Ching-yi; Liou, Tsan-hon; Lin, Jui-chi; Hung, Jen-wen

    2016-03-22

    The combination of robot-assisted therapy (RT) and a modified form of constraint-induced therapy (mCIT) shows promise for improving motor function of patients with stroke. However, whether the changes of motor control strategies are concomitant with the improvements in motor function after combination of RT and mCIT (RT + mCIT) is unclear. This study investigated the effects of the sequential combination of RT + mCIT compared with RT alone on the strategies of motor control measured by kinematic analysis and on motor function and daily performance measured by clinical scales. The study enrolled 34 patients with chronic stroke. The data were derived from part of a single-blinded randomized controlled trial. Participants in the RT + mCIT and RT groups received 20 therapy sessions (90 to 105 min/day, 5 days for 4 weeks). Patients in the RT + mCIT group received 10 RT sessions for first 2 weeks and 10 mCIT sessions for the next 2 weeks. The Bi-Manu-Track was used in RT sessions to provide bilateral practice of wrist and forearm movements. The primary outcome was kinematic variables in a task of reaching to press a desk bell. Secondary outcomes included scores on the Wolf Motor Function Test, Functional Independence Measure, and Nottingham Extended Activities of Daily Living. All outcome measures were administered before and after intervention. RT + mCIT and RT demonstrated different benefits on motor control strategies. RT + mCIT uniquely improved motor control strategies by reducing shoulder abduction, increasing elbow extension, and decreasing trunk compensatory movement during the reaching task. Motor function and quality of the affected limb was improved, and patients achieved greater independence in instrumental activities of daily living. Force generation at movement initiation was improved in the patients who received RT. A combination of RT and mCIT could be an effective approach to improve stroke rehabilitation outcomes, achieving

  15. Robotic assisted laparoscopic colectomy.

    LENUS (Irish Health Repository)

    Pandalai, S

    2010-06-01

    Robotic surgery has evolved over the last decade to compensate for limitations in human dexterity. It avoids the need for a trained assistant while decreasing error rates such as perforations. The nature of the robotic assistance varies from voice activated camera control to more elaborate telerobotic systems such as the Zeus and the Da Vinci where the surgeon controls the robotic arms using a console. Herein, we report the first series of robotic assisted colectomies in Ireland using a voice activated camera control system.

  16. Robotic assisted andrological surgery

    Science.gov (United States)

    Parekattil, Sijo J; Gudeloglu, Ahmet

    2013-01-01

    The introduction of the operative microscope for andrological surgery in the 1970s provided enhanced magnification and accuracy, unparalleled to any previous visual loop or magnification techniques. This technology revolutionized techniques for microsurgery in andrology. Today, we may be on the verge of a second such revolution by the incorporation of robotic assisted platforms for microsurgery in andrology. Robotic assisted microsurgery is being utilized to a greater degree in andrology and a number of other microsurgical fields, such as ophthalmology, hand surgery, plastics and reconstructive surgery. The potential advantages of robotic assisted platforms include elimination of tremor, improved stability, surgeon ergonomics, scalability of motion, multi-input visual interphases with up to three simultaneous visual views, enhanced magnification, and the ability to manipulate three surgical instruments and cameras simultaneously. This review paper begins with the historical development of robotic microsurgery. It then provides an in-depth presentation of the technique and outcomes of common robotic microsurgical andrological procedures, such as vasectomy reversal, subinguinal varicocelectomy, targeted spermatic cord denervation (for chronic orchialgia) and robotic assisted microsurgical testicular sperm extraction (microTESE). PMID:23241637

  17. Robot-assisted general surgery.

    Science.gov (United States)

    Hazey, Jeffrey W; Melvin, W Scott

    2004-06-01

    With the initiation of laparoscopic techniques in general surgery, we have seen a significant expansion of minimally invasive techniques in the last 16 years. More recently, robotic-assisted laparoscopy has moved into the general surgeon's armamentarium to address some of the shortcomings of laparoscopic surgery. AESOP (Computer Motion, Goleta, CA) addressed the issue of visualization as a robotic camera holder. With the introduction of the ZEUS robotic surgical system (Computer Motion), the ability to remotely operate laparoscopic instruments became a reality. US Food and Drug Administration approval in July 2000 of the da Vinci robotic surgical system (Intuitive Surgical, Sunnyvale, CA) further defined the ability of a robotic-assist device to address limitations in laparoscopy. This includes a significant improvement in instrument dexterity, dampening of natural hand tremors, three-dimensional visualization, ergonomics, and camera stability. As experience with robotic technology increased and its applications to advanced laparoscopic procedures have become more understood, more procedures have been performed with robotic assistance. Numerous studies have shown equivalent or improved patient outcomes when robotic-assist devices are used. Initially, robotic-assisted laparoscopic cholecystectomy was deemed safe, and now robotics has been shown to be safe in foregut procedures, including Nissen fundoplication, Heller myotomy, gastric banding procedures, and Roux-en-Y gastric bypass. These techniques have been extrapolated to solid-organ procedures (splenectomy, adrenalectomy, and pancreatic surgery) as well as robotic-assisted laparoscopic colectomy. In this chapter, we review the evolution of robotic technology and its applications in general surgical procedures.

  18. Evaluation of reach and grasp robot-assisted therapy suggests similar functional recovery patterns on proximal and distal arm segments in sub-acute hemiplegia.

    Science.gov (United States)

    Loureiro, Rui C V; Harwin, William S; Lamperd, Robert; Collin, Christine

    2014-05-01

    This paper provides some additional evidence in support of the hypothesis that robot therapies are clinically beneficial in neurorehabilitation. Although only four subjects were included in the study, the design of the intervention and the measures were done so as to minimize bias. The results are presented as single case studies, and can only be interpreted as such due to the study size. The intensity of intervention was 16 h and the therapy philosophy (based on Carr and Shepherd) was that coordinated movements are preferable to joint based therapies, and that coordinating distal movements (in this case grasps) helps not only to recover function in these areas, but has greater value since the results are immediately transferable to daily skills such as reach and grasp movements.

  19. [Robot-assisted pancreatic resection].

    Science.gov (United States)

    Müssle, B; Distler, M; Weitz, J; Welsch, T

    2017-06-01

    Although robot-assisted pancreatic surgery has been considered critically in the past, it is nowadays an established standard technique in some centers, for distal pancreatectomy and pancreatic head resection. Compared with the laparoscopic approach, the use of robot-assisted surgery seems to be advantageous for acquiring the skills for pancreatic, bile duct and vascular anastomoses during pancreatic head resection and total pancreatectomy. On the other hand, the use of the robot is associated with increased costs and only highly effective and professional robotic programs in centers for pancreatic surgery will achieve top surgical and oncological quality, acceptable operation times and a reduction in duration of hospital stay. Moreover, new technologies, such as intraoperative fluorescence guidance and augmented reality will define additional indications for robot-assisted pancreatic surgery.

  20. Robotic assistants for universal access

    OpenAIRE

    Keates, Simeon; Kyberd, Peter J.

    2017-01-01

    Much research is now focusing on how technology is moving away from the traditional computer to a range of smart devices in smart environments, the so-called Internet of Things. With this increase in computing power and decrease in form factor, we are approaching the possibility of a new generation of robotic assistants able to perform a range of tasks and activities to support all kinds of users. However, history shows that unless care is taken early in the design process, the users who may ...

  1. Advancements in robotic-assisted thoracic surgery.

    Science.gov (United States)

    Steenwyk, Brad; Lyerly, Ralph

    2012-12-01

    Advancements in robotic-assisted thoracic surgery present potential advantages for patients as well as new challenges for the anesthesia and surgery teams. This article describes the major aspects of the surgical approach for the most commonly performed robotic-assisted thoracic surgical procedures as well as the pertinent preoperative, intraoperative, and postoperative anesthetic concerns. Copyright © 2012. Published by Elsevier Inc.

  2. Robot-assisted surgery in gynecological oncology

    DEFF Research Database (Denmark)

    Kristensen, Steffen E; Mosgaard, Berit J; Rosendahl, Mikkel

    2017-01-01

    INTRODUCTION: Robot-assisted surgery has become more widespread in gynecological oncology. The purpose of this systematic review is to present current knowledge on robot-assisted surgery, and to clarify and discuss controversies that have arisen alongside the development and deployment. MATERIAL...... was performed by screening of titles and abstracts, and by full text scrutiny. From 2001 to 2016, a total of 76 references were included. RESULTS: Robot-assisted surgery in gynecological oncology has increased, and current knowledge supports that the oncological safety is similar, compared with previous...

  3. Robotic-assisted surgery in ophthalmology.

    Science.gov (United States)

    de Smet, Marc D; Naus, Gerrit J L; Faridpooya, Koorosh; Mura, Marco

    2018-05-01

    Provide an overview of the current landscape of robotics in ophthalmology, including the pros and cons of system designs, the clinical development path, and the likely future direction of the field. Robots designed for eye surgery should meet certain basic requirements. Three designs are currently being developed: smart surgical tools such as the steady hand, comanipulation devices and telemanipulators using either a fixed or virtual remote center of motion. Successful human intraocular surgery is being performed using the Preceyes surgical system. Another telemanipulation robot, the da Vinci Surgical System, has been used to perform a pterygium repair in humans and was successful in ex-vivo corneal surgery despite its nonophthalmic design. Apart from Preceyes' BV research platform, none of the currently eye-specific systems has reached a commercial stage. Systems are likely to evolve from robotic assistance during specific procedural steps to semiautonomous surgery, as smart sensors are introduced to enhance the basic functionalities of robotic systems. Robotics is still in its infancy in ophthalmology but is rapidly reaching a stage wherein it will be introduced into everyday ophthalmic practice. It will most likely be introduced first for demanding vitreo-retinal procedures, followed by anterior segment applications.

  4. Limited Evidence for Robot-assisted Surgery

    DEFF Research Database (Denmark)

    Broholm, Malene; Onsberg Hansen, Iben; Rosenberg, Jacob

    2016-01-01

    -assisted surgery. Open versus robot-assisted surgery was investigated in 3 studies. A lower blood loss and a longer operative time were found after robot-assisted surgery. No other difference was detected. CONCLUSIONS: At this point there is not enough evidence to support the significantly higher costs......PURPOSE: To evaluate available evidence on robot-assisted surgery compared with open and laparoscopic surgery. METHOD: The databases Medline, Embase, and Cochrane Library were systematically searched for randomized controlled trials comparing robot-assisted surgery with open and laparoscopic...... surgery regardless of surgical procedure. Meta-analyses were performed on each outcome with appropriate data material available. Cochrane Collaboration's tool for assessing risk of bias was used to evaluate risk of bias on a study level. The GRADE approach was used to evaluate the quality of evidence...

  5. Review: Robot assisted laparoscopic surgery in gynaecological ...

    African Journals Online (AJOL)

    Review: Robot assisted laparoscopic surgery in gynaecological oncology. ... robot suggests "to be able to act without human interference and being able to ... or in space), its use as telesurgery is still very limited and practically not feasible.

  6. The immediate effects of robot-assistance on energy consumption and cardiorespiratory load during walking compared to walking without robot-assistance: a systematic review.

    Science.gov (United States)

    Lefeber, Nina; Swinnen, Eva; Kerckhofs, Eric

    2017-10-01

    effort. These parameters could be adjusted in RAG rehabilitation to make RAG more or less energy-consuming and cardiorespiratory stressful. Overall, short duration exoskeleton walking seems less energy-consuming and cardiorespiratory stressful than walking without robot-assistance. This might implicate that the exercise intensity is safe for (neurological) patients at risk of cardiovascular diseases. How this changes in extended walking time is unclear.

  7. Robot-assisted laparoscopic myomectomy: current status

    OpenAIRE

    Arian,Sara; Munoz,Jessian; Kim,Suejin; Falcone,Tommaso

    2017-01-01

    Sara E Arian, Jessian L Munoz, Suejin Kim, Tommaso Falcone Department of Obstetrics, Gynecology, and Women’s Health Institute, Cleveland Clinic, Cleveland, OH, USA Abstract: Robotic-assisted surgery has seen a rapid development and integration in the field of gynecology. Since the approval of the use of robot for gynecological surgery and considering its several advantages over conventional laparoscopy, it has been widely incorporated especially in the field of reproductive surgery....

  8. Current perspectives in robotic assisted surgery.

    Science.gov (United States)

    Binet, Aurélien; Ballouhey, Quentin; Chaussy, Yann; de Lambert, Guénolée; Braïk, Karim; Villemagne, Thierry; Becmeur, François; Fourcade, Laurent; Lardy, Hubert

    2018-02-23

    From classical surgery to Robotic Assisted Surgery, there is a long way allowed by Minimal Invasive Surgery' improvements. The last three decades have witnessed a prodigious development of minimally invasive surgery (MIS) and especially in the field of laparoscopic pediatric surgery but there are several limitations in the use of conventional laparoscopic surgery and Robotic Assisted Surgery was developed to relieve these drawbacks. This new technology enables today the performance of a wide variety of procedures in children with a minimally invasive approach. As for all new technologies, an objective evaluation is essential with the need to respond to several questions: Is the technology feasible? Is the technology safe? Is the technology efficient? Does it bring about benefits compared with current technology? What are the procedures derived from most benefits of robotic assistance? How to assume the transition from open surgery to Minimal Invasive access for RAS? In the first part of this article, the authors give details about technical concerns and then describe the implementation process with its organization, pitfalls, successes, and issues from human resources and financial standpoints. The learning curve is then described and a special focus on small children weighing less than 15 Kg is developed. Finally, the concept of evaluation of this emerging technology is evocated and financial concerns are developed.

  9. Robot assistant versus human or another robot assistant in patients undergoing laparoscopic cholecystectomy.

    Science.gov (United States)

    Gurusamy, Kurinchi Selvan; Samraj, Kumarakrishnan; Fusai, Giuseppe; Davidson, Brian R

    2012-09-12

    The role of a robotic assistant in laparoscopic cholecystectomy is controversial. While some trials have shown distinct advantages of a robotic assistant over a human assistant others have not, and it is unclear which robotic assistant is best. The aims of this review are to assess the benefits and harms of a robot assistant versus human assistant or versus another robot assistant in laparoscopic cholecystectomy, and to assess whether the robot can substitute the human assistant. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) in The Cochrane Library, MEDLINE, EMBASE, and Science Citation Index Expanded (until February 2012) for identifying the randomised clinical trials. Only randomised clinical trials (irrespective of language, blinding, or publication status) comparing robot assistants versus human assistants in laparoscopic cholecystectomy were considered for the review. Randomised clinical trials comparing different types of robot assistants were also considered for the review. Two authors independently identified the trials for inclusion and independently extracted the data. We calculated the risk ratio (RR) or mean difference (MD) with 95% confidence interval (CI) using the fixed-effect and the random-effects models based on intention-to-treat analysis, when possible, using Review Manager 5. We included six trials with 560 patients. One trial involving 129 patients did not state the number of patients randomised to the two groups. In the remaining five trials 431 patients were randomised, 212 to the robot assistant group and 219 to the human assistant group. All the trials were at high risk of bias. Mortality and morbidity were reported in only one trial with 40 patients. There was no mortality or morbidity in either group. Mortality and morbidity were not reported in the remaining trials. Quality of life or the proportion of patients who were discharged as day-patient laparoscopic cholecystectomy patients were not reported in any

  10. ROBOT-ASSISTED LAPAROSCOPIC PROSTATECTOMY: OUR EXPERIENCE

    Directory of Open Access Journals (Sweden)

    S. N. Nesterov

    2014-08-01

    Full Text Available Background. Retropubic radical prostatectomy (RPE is now the gold standard of treatment for locally advanced prostate cancer (PC. However, robot-assisted RPE procedures using the da Vinci system are finding increasing acceptance.Materials and methods. The authors conducted a prospective study of 60 robot-assisted prostatectomies made at the Clinic of Urology, N.I. Pirogov National Medical Surgical Center, in the period January 2009 to December 2010.Results. The duration of an operation averaged 230 min; the average amount of blood loss was 200 ml. The mean duration of postoperative analgesia was 2,7 days. That of urinary catheterization was 8.5 days. A normal postoperative course was noted in most cases (88,4 %. Seven patients were found to have 8 (13,3 % mild and moderate complications. A pathohistological study revealed a positive surgical margin of resection in 21,7 % of the patients, extracapsular tumor growth in 21,7 %, and seminal vesicle invasion in 23,3 %. Tumor-affected regional lymph nodes were detected in 1 (1,7 % patient. In our observed series, 82 and 93 % of the subjects completely retained urine after 6 and 12 moths, respectively. Throughout the follow-up, erectile function recovered in 7 of the 15 patients undergoing a nerve-sparing surgical procedure.Conclusion. Postoperative results in our series of interventions are comparable to those obtained in the studies by Russian and foreign colleagues at the early stage of mastering this procedure. By considering a few observations, it is today difficult to say that our study is valid in the context of evidence-based medicine. Estimation of the benefits of robot-assisted laparoscopic prostatectomy calls for long-term multicenter randomized trials.

  11. Virtual tutor systems for robot-assisted instruction

    Science.gov (United States)

    Zhao, Zhijing; Zhao, Deyu; Zhang, Zizhen; Wei, Yongji; Qi, Bingchen; Okawa, Yoshikuni

    2004-03-01

    Virtual Reality technology belongs to advanced computer technology, it has been applied in instruction field and gains obvious effect. At the same time, robot assisted instruction comes true with the continuous development of Robot technology and artificial intelligence technology. This paper introduces a virtual tutor system for robot assisted instruction.

  12. Robot-assisted radical prostatectomy is a safe procedure

    DEFF Research Database (Denmark)

    Thomsen, Frederik Birkebæk; Berg, Kasper Drimer; Hvarness, Helle

    2013-01-01

    We present our departmental experience with robot-assisted radical prostatectomy and describe complications and early results for the first 239 consecutive patients.......We present our departmental experience with robot-assisted radical prostatectomy and describe complications and early results for the first 239 consecutive patients....

  13. Robotic-assisted versus laparoscopic colectomy: cost and clinical outcomes.

    Science.gov (United States)

    Davis, Bradley R; Yoo, Andrew C; Moore, Matt; Gunnarsson, Candace

    2014-01-01

    Laparoscopic colectomies, with and without robotic assistance, are performed to treat both benign and malignant colonic disease. This study compared clinical and economic outcomes for laparoscopic colectomy procedures with and without robotic assistance. Patients aged ≥18 years having primary inpatient laparoscopic colectomy procedures (cecectomy, right hemicolectomy, left hemicolectomy, and sigmoidectomy) identified by International Classification of Diseases, Ninth Edition procedure codes performed between 2009 and the second quarter of 2011 from the Premier Hospital Database were studied. Patients were matched to a control cohort using propensity scores for disease, comorbidities, and hospital characteristics and were matched 1:1 for specific colectomy procedure. The outcomes of interest were hospital cost of laparoscopic robotic-assisted colectomy compared with traditional laparoscopic colectomy, surgery time, adverse events, and length of stay. Of 25,758 laparoscopic colectomies identified, 98% were performed without robotic assistance and 2% were performed with robotic assistance. After matching, 1066 patients remained, 533 in each group. Lengths of stay were not significantly different between the matched cohorts, nor were rates of major, minor, and/or surgical complications. Inpatient procedures with robotic assistance were significantly more costly than those without robotic assistance ($17,445 vs $15,448, P = .001). Operative times were significantly longer for robotic-assisted procedures (4.37 hours vs 3.34 hours, P < .001). Segmental colectomies can be performed safely by either laparoscopic or robotic-assisted methods. Increased per-case hospital costs for robotic-assisted procedures and prolonged operative times suggest that further investigation is warranted when considering robotic technology for routine laparoscopic colectomies.

  14. An Informationally Structured Room for Robotic Assistance

    Directory of Open Access Journals (Sweden)

    Tokuo Tsuji

    2015-04-01

    Full Text Available The application of assistive technologies for elderly people is one of the most promising and interesting scenarios for intelligent technologies in the present and near future. Moreover, the improvement of the quality of life for the elderly is one of the first priorities in modern countries and societies. In this work, we present an informationally structured room that is aimed at supporting the daily life activities of elderly people. This room integrates different sensor modalities in a natural and non-invasive way inside the environment. The information gathered by the sensors is processed and sent to a centralized management system, which makes it available to a service robot assisting the people. One important restriction of our intelligent room is reducing as much as possible any interference with daily activities. Finally, this paper presents several experiments and situations using our intelligent environment in cooperation with our service robot.

  15. Cardiopulmonary performance testing using a robotics-assisted tilt table: feasibility assessment in able-bodied subjects.

    Science.gov (United States)

    Saengsuwan, J; Laubacher, M; Nef, T; Hunt, K J

    2014-01-01

    Robotics-assisted tilt table technology was introduced for early rehabilitation of neurological patients. It provides cyclical stepping movement and physiological loading of the legs. The aim of the present study was to assess the feasibility of this type of device for peak cardiopulmonary performance testing using able-bodied subjects. A robotics-assisted tilt table was augmented with force sensors in the thigh cuffs and a work rate estimation algorithm. A custom visual feedback system was employed to guide the subjects' work rate and to provide real time feedback of actual work rate. Feasibility assessment focused on: (i) implementation (technical feasibility), and (ii) responsiveness (was there a measurable, high-level cardiopulmonary reaction?). For responsiveness testing, each subject carried out an incremental exercise test to the limit of functional capacity with a work rate increment of 5 W/min in female subjects and 8 W/min in males. 11 able-bodied subjects were included (9 male, 2 female; age 29.6 ± 7.1 years: mean ± SD). Resting oxygen uptake (O_{2}) was 4.6 ± 0.7 mL/min/kg and O_{2}peak was 32.4 ± 5.1 mL/min/kg; this mean O_{2}peak was 81.1% of the predicted peak value for cycle ergometry. Peak heart rate (HRpeak) was 177.5 ± 9.7 beats/min; all subjects reached at least 85% of their predicted HRpeak value. Respiratory exchange ratio (RER) at O_{2}peak was 1.02 ± 0.07. Peak work rate) was 61.3 ± 15.1 W. All subjects reported a Borg CR10 value for exertion and leg fatigue of 7 or more. The robotics-assisted tilt table is deemed feasible for peak cardiopulmonary performance testing: the approach was found to be technically implementable and substantial cardiopulmonary responses were observed. Further testing in neurologically-impaired subjects is warranted.

  16. Robotically assisted MRgFUS system

    Science.gov (United States)

    Jenne, Jürgen W.; Krafft, Axel J.; Maier, Florian; Rauschenberg, Jaane; Semmler, Wolfhard; Huber, Peter E.; Bock, Michael

    2010-03-01

    Magnetic resonance imaging guided focus ultrasound surgery (MRgFUS) is a highly precise method to ablate tissue non-invasively. The objective of this ongoing work is to establish an MRgFUS therapy unit consisting of a specially designed FUS applicator as an add-on to a commercial robotic assistance system originally designed for percutaneous needle interventions in whole-body MRI systems. The fully MR compatible robotic assistance system InnoMotion™ (Synthes Inc., West Chester, USA; formerly InnoMedic GmbH, Herxheim, Germany) offers six degrees of freedom. The developed add-on FUS treatment applicator features a fixed focus ultrasound transducer (f = 1.7 MHz; f' = 68 mm, NA = 0.44, elliptical shaped -6-dB-focus: 8.1 mm length; O/ = 1.1 mm) embedded in a water-filled flexible bellow. A Mylar® foil is used as acoustic window encompassed by a dedicated MRI loop coil. For FUS application, the therapy unit is directly connected to the head of the robotic system, and the treatment region is targeted from above. A newly in-house developed software tool allowed for complete remote control of the MRgFUS-robot system and online analysis of MRI thermometry data. The system's ability for therapeutic relevant focal spot scanning was tested in a closed-bore clinical 1.5 T MR scanner (Magnetom Symphony, Siemens AG, Erlangen, Germany) in animal experiments with pigs. The FUS therapy procedure was performed entirely under MRI guidance including initial therapy planning, online MR-thermometry, and final contrast enhanced imaging for lesion detection. In vivo trials proved the MRgFUS-robot system as highly MR compatible. MR-guided focal spot scanning experiments were performed and a well-defined pattern of thermal tissue lesions was created. A total in vivo positioning accuracy of the US focus better than 2 mm was estimated which is comparable to existing MRgFUS systems. The newly developed FUS-robotic system offers an accurate, highly flexible focus positioning. With its access

  17. Surgical Residents are Excluded From Robot-assisted Surgery

    DEFF Research Database (Denmark)

    Broholm, Malene; Rosenberg, Jacob

    2015-01-01

    PURPOSE: Implementation of a robotic system may influence surgical training. The aim was to report the charge of the operating surgeon and the bedside assistant at robot-assisted procedures in urology, gynecology, and colorectal surgery. MATERIALS AND METHODS: A review of hospital charts from...... performed. In 10 (1.3%) of these procedures, a resident attended as bedside assistant and never as operating surgeon in the console. CONCLUSIONS: Our results demonstrate a severe problem with surgical education. Robot-assisted surgery is increasingly used; however, robotic surgical training during residency...... surgical procedures during a 1-year period from October 2013 to October 2014. All robot-assisted urologic, gynecologic, and colorectal procedures were identified. Charge of both operating surgeon in the console and bedside assistant were registered. RESULTS: A total of 774 robot-assisted procedures were...

  18. Early results after robot-assisted colorectal surgery

    DEFF Research Database (Denmark)

    Eriksen, Jens Ravn; Helvind, Neel Maria; Jakobsen, Henrik Loft

    2013-01-01

    Implementation of robotic technology in surgery is challenging in many ways. The aim of this study was to present the implementation process and results of the first two years of consecutive robot-assisted laparoscopic (RAL) colorectal procedures.......Implementation of robotic technology in surgery is challenging in many ways. The aim of this study was to present the implementation process and results of the first two years of consecutive robot-assisted laparoscopic (RAL) colorectal procedures....

  19. Robot-assisted automatic ultrasound calibration.

    Science.gov (United States)

    Aalamifar, Fereshteh; Cheng, Alexis; Kim, Younsu; Hu, Xiao; Zhang, Haichong K; Guo, Xiaoyu; Boctor, Emad M

    2016-10-01

    Ultrasound (US) calibration is the process of determining the unknown transformation from a coordinate frame such as the robot's tooltip to the US image frame and is a necessary task for any robotic or tracked US system. US calibration requires submillimeter-range accuracy for most applications, but it is a time-consuming and repetitive task. We provide a new framework for automatic US calibration with robot assistance and without the need for temporal calibration. US calibration based on active echo (AE) phantom was previously proposed, and its superiority over conventional cross-wire phantom-based calibration was shown. In this work, we use AE to guide the robotic arm motion through the process of data collection; we combine the capability of the AE point to localize itself in the frame of the US image with the automatic motion of the robotic arm to provide a framework for calibrating the arm to the US image automatically. We demonstrated the efficacy of the automated method compared to the manual method through experiments. To highlight the necessity of frequent ultrasound calibration, it is demonstrated that the calibration precision changed from 1.67 to 3.20 mm if the data collection is not repeated after a dismounting/mounting of the probe holder. In a large data set experiment, similar reconstruction precision of automatic and manual data collection was observed, while the time was reduced by 58 %. In addition, we compared ten automatic calibrations with ten manual ones, each performed in 15 min, and showed that all the automatic ones could converge in the case of setting the initial matrix as identity, while this was not achieved by manual data sets. Given the same initial matrix, the repeatability of the automatic was [0.46, 0.34, 0.80, 0.47] versus [0.42, 0.51, 0.98, 1.15] mm in the manual case for the US image four corners. The submillimeter accuracy requirement of US calibration makes frequent data collections unavoidable. We proposed an automated

  20. Validation of ergonomic instructions in robot-assisted surgery simulator training.

    Science.gov (United States)

    Van't Hullenaar, C D P; Mertens, A C; Ruurda, J P; Broeders, I A M J

    2018-05-01

    Training in robot-assisted surgery focusses mainly on technical skills and instrument use. Training in optimal ergonomics during robotic surgery is often lacking, while improved ergonomics can be one of the key advantages of robot-assisted surgery. Therefore, the aim of this study was to assess whether a brief explanation on ergonomics of the console can improve body posture and performance. A comparative study was performed with 26 surgical interns and residents using the da Vinci skills simulator (Intuitive Surgical, Sunnyvale, CA). The intervention group received a compact instruction on ergonomic settings and coaching on clutch usage, while the control group received standard instructions for usage of the system. Participants performed two sets of five exercises. Analysis was performed on ergonomic score (RULA) and performance scores provided by the simulator. Mental and physical load scores (NASA-TLX and LED score) were also registered. The intervention group performed better in the clutch-oriented exercises, displaying less unnecessary movement and smaller deviation from the neutral position of the hands. The intervention group also scored significantly better on the RULA ergonomic score in both the exercises. No differences in overall performance scores and subjective scores were detected. The benefits of a brief instruction on ergonomics for novices are clear in this study. A single session of coaching and instruction leads to better ergonomic scores. The control group showed often inadequate ergonomic scores. No significant differences were found regarding physical discomfort, mental task load and overall performance scores.

  1. Real-Time Augmented Reality for Robotic-Assisted Surgery

    DEFF Research Database (Denmark)

    Jørgensen, Martin Kibsgaard; Kraus, Martin

    2015-01-01

    Training in robotic-assisted minimally invasive surgery is crucial, but the training with actual surgery robots is relatively expensive. Therefore, improving the efficiency of this training is of great interest in robotic surgical education. One of the current limitations of this training is the ......-dimensional computer graphics in real time. Our system makes it possible to easily deploy new user interfaces for robotic-assisted surgery training. The system has been positively evaluated by two experienced instructors in robot-assisted surgery....... is the limited visual communication between the instructor and the trainee. As the trainee's view is limited to that of the surgery robot's camera, even a simple task such as pointing is difficult. We present a compact system to overlay the video streams of the da Vinci surgery systems with interactive three...

  2. Robot-assisted partial nephrectomy in contemporary practice

    Directory of Open Access Journals (Sweden)

    Youssef S. Tanagho

    2013-01-01

    Full Text Available Laparoscopic renal surgery is associated with reduced blood loss, shorter hospital stay, enhanced cosmesis, and more rapid convalescence relative to open renal surgery. Laparoscopic partial nephrectomy is a minimally invasive, nephron-sparing alternative to laparoscopic radical nephrectomy for the management of small renal masses. While offering similar oncological outcomes to laparoscopic radical nephrectomy, the technical challenges and prolonged learning curve associated with laparoscopic partial nephrectomy limit its wider dissemination. Robot-assisted partial nephrectomy, although still an evolving procedure with no long-term data, has emerged as a viable alternative to laparoscopic partial nephrectomy, with favorable preliminary outcomes. This article provides an overview of the role of robot-assisted partial nephrectomy in the management of renal cell carcinoma. The clinical indications and principles of surgical technique for this procedure are discussed. The oncological, renal functional, and perioperative outcomes of robot-assisted partial nephrectomy are also evaluated, as are complication rates.

  3. Da Vinci Xi Robot-Assisted Penetrating Keratoplasty.

    Science.gov (United States)

    Chammas, Jimmy; Sauer, Arnaud; Pizzuto, Joëlle; Pouthier, Fabienne; Gaucher, David; Marescaux, Jacques; Mutter, Didier; Bourcier, Tristan

    2017-06-01

    This study aims (1) to investigate the feasibility of robot-assisted penetrating keratoplasty (PK) using the new Da Vinci Xi Surgical System and (2) to report what we believe to be the first use of this system in experimental eye surgery. Robot-assisted PK procedures were performed on human corneal transplants using the Da Vinci Xi Surgical System. After an 8-mm corneal trephination, four interrupted sutures and one 10.0 monofilament running suture were made. For each procedure, duration and successful completion of the surgery as well as any unexpected events were assessed. The depth of the corneal sutures was checked postoperatively using spectral-domain optical coherence tomography (SD-OCT). Robot-assisted PK was successfully performed on 12 corneas. The Da Vinci Xi Surgical System provided the necessary dexterity to perform the different steps of surgery. The mean duration of the procedures was 43.4 ± 8.9 minutes (range: 28.5-61.1 minutes). There were no unexpected intraoperative events. SD-OCT confirmed that the sutures were placed at the appropriate depth. We confirm the feasibility of robot-assisted PK with the new Da Vinci Surgical System and report the first use of the Xi model in experimental eye surgery. Operative time of robot-assisted PK surgery is now close to that of conventional manual surgery due to both improvement of the optical system and the presence of microsurgical instruments. Experimentations will allow the advantages of robot-assisted microsurgery to be identified while underlining the improvements and innovations necessary for clinical use.

  4. Initial Clinical Experience With Surgical Technique of Robot-assisted Transperitoneal Laparoscopic Partial Nephrectomy

    Directory of Open Access Journals (Sweden)

    Cheng-Kuang Yang

    2009-12-01

    Conclusion: Robot-assisted LPN is feasible and may be a viable alternative to open or LPN in selected patients with small exophytic renal tumors. Compared with standard LPN, the robotic assisted LPN approach with precise renal reconstruction under a safe warm ischemia time is feasible and can be easily adopted by those with experience in robot-assisted surgery.

  5. Robot-assisted Heller's myotomy for achalasia in children.

    Science.gov (United States)

    Altokhais, Tariq; Mandora, Hala; Al-Qahtani, Ayed; Al-Bassam, Abdulrahman

    2016-12-01

    Achalasia is rare in children. Surgical options include open, laparoscopic and robotic approaches. However, Heller's myotomy remains the treatment of choice. This report describes our experience with robot-assisted Heller's myotomy in children and presents a review of the literature. Included in this study are children who underwent robot-assisted Heller's myotomy for esophageal achalasia via the Da Vinci surgical system between 2004 and 2015 at King Saud University Medical City, Riyadh, Saudi Arabia. The medical records of these patients were reviewed for demographic data, presenting symptoms, diagnostic modalities, operative procedures, complications, outcomes and follow-ups. Six patients were identified. The age of the patients at surgery ranged between 2 and 12 years (mean 7.1 years). The most common presenting symptoms were dysphagia, vomiting and nocturnal cough. Contrast swallow and upper gastrointestinal endoscopy established a diagnosis of esophageal achalasia in all of the patients. Four patients underwent esophageal dilatation 2-5 times before the definitive procedure. All patients underwent successful robot-assisted Heller's myotomy with concomitant partial posterior fundoplication. The postoperative course was uneventful. Five patients had a complete resolution of the symptoms and one patient improved. The follow-up assessments have been consistent and have ranged from 0.5 to 11 years (mean 4.4 years). Robotic-assisted Heller's myotomy for esophageal achalasia in children is safe and effective and is a suitable alternative to open and laparoscopic approaches.

  6. [Simulation-based robot-assisted surgical training].

    Science.gov (United States)

    Kolontarev, K B; Govorov, A V; Rasner, P I; Sheptunov, S A; Prilepskaya, E A; Maltsev, E G; Pushkar, D Yu

    2015-12-01

    Since the first use of robotic surgical system in 2000, the robot-assisted technology has gained wide popularity throughout the world. Robot-assisted surgical training is a complex issue that requires significant efforts from students and teacher. During the last two decades, simulation-based training had received active development due to wide-spread occurrence and popularization of laparoscopic and robot-assisted surgical techniques. We performed a systematic review to identify the currently available simulators for robot-assisted surgery. We searched the Medline and Pubmed, English sources of literature data, using the following key words and phrases: "robotics", "robotic surgery", "computer assisted surgery", "simulation", "computer simulation", "virtual reality", "surgical training", and "surgical education". There were identified 565 publications, which meet the key words and phrases; 19 publications were selected for the final analysis. It was established that simulation-based training is the most promising teaching tool that can be used in the training of the next generation robotic surgeons. Today the use of simulators to train surgeons is validated. Price of devices is an obvious barrier for inclusion in the program for training of robotic surgeons, but the lack of this tool will result in a sharp increase in the duration of specialists training.

  7. Robotic-assisted thermal ablation of liver tumours

    International Nuclear Information System (INIS)

    Abdullah, Basri Johan Jeet; Yeong, Chai Hong; Goh, Khean Lee; Yoong, Boon Koon; Ho, Gwo Fuang; Yim, Carolyn Chue Wai; Kulkarni, Anjali

    2015-01-01

    This study aimed to assess the technical success, radiation dose, safety and performance level of liver thermal ablation using a computed tomography (CT)-guided robotic positioning system. Radiofrequency and microwave ablation of liver tumours were performed on 20 patients (40 lesions) with the assistance of a CT-guided robotic positioning system. The accuracy of probe placement, number of readjustments and total radiation dose to each patient were recorded. The performance level was evaluated on a five-point scale (5-1: excellent-poor). The radiation doses were compared against 30 patients with 48 lesions (control) treated without robotic assistance. Thermal ablation was successfully completed in 20 patients with 40 lesions and confirmed on multiphasic contrast-enhanced CT. No procedure related complications were noted in this study. The average number of needle readjustment was 0.8 ± 0.8. The total CT dose (DLP) for the entire robotic assisted thermal ablation was 1382 ± 536 mGy.cm, while the CT fluoroscopic dose (DLP) per lesion was 352 ± 228 mGy.cm. There was no statistically significant (p > 0.05) dose reduction found between the robotic-assisted versus the conventional method. This study revealed that robotic-assisted planning and needle placement appears to be safe, with high accuracy and a comparable radiation dose to patients. (orig.)

  8. Robot-assisted bronchoplasty using continuous barbed sutures.

    Science.gov (United States)

    Sarsam, Omar Matthieu; Dunning, Joel; Pochulu, Bruno; Baste, Jean-Marc

    2018-01-01

    We describe in this article our bronchoplastic robot-assisted techniques. This consists of using continuous barbed sutures. Our aim is to show the feasibility and the interest of using robotics and this kind of suture material for complex bronchial procedures. We report four cases in France and the UK, two wedge bronchoplasties and two sleeve bronchoplasties for central pulmonary tumors.

  9. Robotic-assisted thermal ablation of liver tumours

    Energy Technology Data Exchange (ETDEWEB)

    Abdullah, Basri Johan Jeet; Yeong, Chai Hong [University of Malaya, Department of Biomedical Imaging and University of Malaya Research Imaging Centre, Faculty of Medicine, Kuala Lumpur (Malaysia); University of Malaya, Department of Internal Medicine, Faculty of Medicine, Kuala Lumpur (Malaysia); Goh, Khean Lee [University of Malaya, Department of Internal Medicine, Faculty of Medicine, Kuala Lumpur (Malaysia); Yoong, Boon Koon [University of Malaya, Department of Surgery, Faculty of Medicine, Kuala Lumpur (Malaysia); Ho, Gwo Fuang [University of Malaya, Department of Oncology, Faculty of Medicine, Kuala Lumpur (Malaysia); Yim, Carolyn Chue Wai [University of Malaya, Department of Anesthesia, Faculty of Medicine, Kuala Lumpur (Malaysia); Kulkarni, Anjali [Perfint Healthcare Corporation, Florence, OR (United States)

    2015-01-15

    This study aimed to assess the technical success, radiation dose, safety and performance level of liver thermal ablation using a computed tomography (CT)-guided robotic positioning system. Radiofrequency and microwave ablation of liver tumours were performed on 20 patients (40 lesions) with the assistance of a CT-guided robotic positioning system. The accuracy of probe placement, number of readjustments and total radiation dose to each patient were recorded. The performance level was evaluated on a five-point scale (5-1: excellent-poor). The radiation doses were compared against 30 patients with 48 lesions (control) treated without robotic assistance. Thermal ablation was successfully completed in 20 patients with 40 lesions and confirmed on multiphasic contrast-enhanced CT. No procedure related complications were noted in this study. The average number of needle readjustment was 0.8 ± 0.8. The total CT dose (DLP) for the entire robotic assisted thermal ablation was 1382 ± 536 mGy.cm, while the CT fluoroscopic dose (DLP) per lesion was 352 ± 228 mGy.cm. There was no statistically significant (p > 0.05) dose reduction found between the robotic-assisted versus the conventional method. This study revealed that robotic-assisted planning and needle placement appears to be safe, with high accuracy and a comparable radiation dose to patients. (orig.)

  10. Monitoring of Robot Assisted Polishing through parameters of acoustic emission

    DEFF Research Database (Denmark)

    Lazarev, Ruslan; Top, Søren; Bilberg, Arne

    The polishing process is essential for the surface generation of machine tooling components in advanced manufacturing. While robot assisted polishing is faster and more consistent than manual polishing, it can still consume a significant part of ma- chining time and operator presence time...

  11. Robotic-assisted laparoscopic hysterectomy for women with endometrial cancer

    DEFF Research Database (Denmark)

    Herling, Suzanne Forsyth; Møller, Ann M; Palle, Connie

    2017-01-01

    INTRODUCTION: Robotic-assisted laparoscopic hysterectomy (RALH) has become a widely used approach for women with endometrial cancer and has replaced laparotomy. It has been questioned if the increased costs are justified by superior surgical outcomes. The aim of the present study was to examine...

  12. Robot-assisted motor activation monitored by time-domain optical brain imaging

    Science.gov (United States)

    Steinkellner, O.; Wabnitz, H.; Schmid, S.; Steingräber, R.; Schmidt, H.; Krüger, J.; Macdonald, R.

    2011-07-01

    Robot-assisted motor rehabilitation proved to be an effective supplement to conventional hand-to-hand therapy in stroke patients. In order to analyze and understand motor learning and performance during rehabilitation it is desirable to develop a monitor to provide objective measures of the corresponding brain activity at the rehabilitation progress. We used a portable time-domain near-infrared reflectometer to monitor the hemodynamic brain response to distal upper extremity activities. Four healthy volunteers performed two different robot-assisted wrist/forearm movements, flexion-extension and pronation-supination in comparison with an unassisted squeeze ball exercise. A special headgear with four optical measurement positions to include parts of the pre- and postcentral gyrus provided a good overlap with the expected activation areas. Data analysis based on variance of time-of-flight distributions of photons through tissue was chosen to provide a suitable representation of intracerebral signals. In all subjects several of the four detection channels showed a response. In some cases indications were found of differences in localization of the activated areas for the various tasks.

  13. Robot-Assisted Antegrade In-Situ Fenestrated Stent Grafting

    International Nuclear Information System (INIS)

    Riga, Celia V.; Bicknell, Colin D.; Wallace, Daniel; Hamady, Mohamad; Cheshire, Nicholas

    2009-01-01

    To determine the technical feasibility of a novel approach of in-situ fenestration of aortic stent grafts by using a remotely controlled robotic steerable catheter system in the porcine model. A 65-kg pig underwent robot-assisted bilateral antegrade in-situ renal fenestration of an abdominal aortic stent graft with subsequent successful deployment of a bare metal stent into the right renal artery. A 16-mm iliac extension covered stent served as the porcine aortic endograft. Under fluoroscopic guidance, the graft was punctured with a 20-G customized diathermy needle that was introduced and kept in place by the robotic arm. The needle was exchanged for a 4 x 20 mm cutting balloon before successful deployment of the renal stent. Robot-assisted antegrade in-situ fenestration is technically feasible in a large mammalian model. The robotic system enables precise manipulation, stable positioning, and minimum instrumentation of the aorta and its branches while minimizing radiation exposure.

  14. Advances in Robotic-Assisted Radical Prostatectomy over Time

    Directory of Open Access Journals (Sweden)

    Emma F. P. Jacobs

    2013-01-01

    Full Text Available Since the introduction of robot-assisted radical prostatectomy (RALP, robotics has become increasingly more commonplace in the armamentarium of the urologic surgeon. Robotic utilization has exploded across surgical disciplines well beyond the fields of urology and prostate surgery. The literature detailing technical steps, comparison of large surgical series, and even robotically focused randomized control trials are available for review. RALP, the first robot-assisted surgical procedure to achieve widespread use, has recently become the primary approach for the surgical management of localized prostate cancer. As a result, surgeons are constantly trying to refine and improve upon current technical aspects of the operation. Recent areas of published modifications include bladder neck anastomosis and reconstruction, bladder drainage, nerve sparing approaches and techniques, and perioperative and postoperative management including penile rehabilitation. In this review, we summarize recent advances in perioperative management and surgical technique for RALP.

  15. Atypical autonomic dysreflexia during robotic-assisted body weight supported treadmill training in an individual with motor incomplete spinal cord injury.

    Science.gov (United States)

    Geigle, Paula R; Frye, Sara Kate; Perreault, John; Scott, William H; Gorman, Peter H

    2013-03-01

    A 41-year-old man with a history of C6 American Spinal Injury Association (ASIA) Impairment Scale (AIS) C spinal cord injury (SCI), enrolled in an Institutional Review Board (IRB)-approved, robotic-assisted body weight-supported treadmill training (BWSTT), and aquatic exercise research protocol developed asymptomatic autonomic dysreflexia (AD) during training. Little information is available regarding the relationship of robotic-assisted BWSTT and AD. After successfully completing 36 sessions of aquatic exercise, he reported exertional fatigue during his 10th Lokomat intervention and exhibited asymptomatic or silent AD during this and the three subsequent BWSTT sessions. Standard facilitators of AD were assessed and no obvious irritant identified other than the actual physical exertion and positioning required during robotic-assisted BWSTT. Increased awareness of potential silent AD presenting during robotic assisted BWSTT training for individuals with motor incomplete SCI is required as in this case AD clinical signs were not concurrent with occurrence. Frequent vital sign assessment before, during, and at conclusion of each BWSTT session is strongly recommended.

  16. [Robot assisted Frykman-Goldberg procedure. Case report].

    Science.gov (United States)

    Zubieta-O'Farrill, Gregorio; Ramírez-Ramírez, Moisés; Villanueva-Sáenz, Eduardo

    2017-12-01

    Rectal prolapse is defined as the protrusion of the rectal wall through the anal canal; with a prevalence of less than 0.5%. The most frequent symptoms include pain, incomplete defecation sensation with blood and mucus, fecal incontinence and/or constipation. The surgical approach can be perineal or abdominal with the tendency for minimal invasion. Robot-assisted procedures are a novel option that offer technique advantages over open or laparoscopic approaches. 67 year-old female, who presented with rectal prolapse, posterior to an episode of constipation, that required manual reduction, associated with transanal hemorrhage during defecation and occasional fecal incontinence. A RMI defecography was performed that reported complete rectal and uterine prolapse, and cystocele. A robotic assisted Frykman-Goldberg procedure wass performed. There are more than 100 surgical procedures for rectal prolapse treatment. We report the first robot assisted procedure in Mexico. Robotic assisted surgery has the same safety rate as laparoscopic surgery, with the advantages of better instrument mobility, no human hand tremor, better vision, and access to complicated and narrow areas. Robotic surgery as the surgical treatment is a feasible, safe and effective option, there is no difference in recurrence and function compared with laparoscopy. It facilitates the technique, improves nerve preservation and bleeding. Further clinical, prospective and randomized studies to compare the different minimal invasive approaches, their functional and long term results for this pathology are needed. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  17. [Initial experience in robot-assisted colorectal surgery in Mexico].

    Science.gov (United States)

    Villanueva-Sáenz, Eduardo; Ramírez-Ramírez, Moisés Marino; Zubieta-O'Farrill, Gregorio; García-Hernández, Luis

    Colorectal surgery has advanced notably since the introduction of the mechanical suture and the minimally invasive approach. Robotic surgery began in order to satisfy the needs of the patient-doctor relationship, and migrated to the area of colorectal surgery. An initial report is presented on the experience of managing colorectal disease using robot-assisted surgery, as well as an analysis of the current role of this platform. A retrospective study was conducted in order to review five patients with colorectal disease operated using a robot-assisted technique over one year in the initial phase of the learning curve. Gender, age, diagnosis and surgical indication, surgery performed, surgical time, conversion, bleeding, post-operative complications, and hospital stay, were analysed and described. A literature review was performed on the role of robotic assisted surgery in colorectal disease and cancer. The study included 5 patients, 3 men and 2 women, with a mean age of 62.2 years. Two of them were low anterior resections with colorectal primary anastomoses, one of them extended with a loop protection ileostomy, a Frykman-Goldberg procedure, and two left hemicolectomies with primary anastomoses. The mean operating time was 6hours and robot-assisted 4hours 20minutes. There were no conversions and the mean hospital stay was 5 days. This technology is currently being used worldwide in different surgical centres because of its advantages that have been clinically demonstrated by various studies. We report the first colorectal surgical cases in Mexico, with promising results. There is enough evidence to support and recommend the use of this technology as a viable and safe option. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  18. Perioperative outcomes of video- and robot-assisted segmentectomies.

    Science.gov (United States)

    Rinieri, Philippe; Peillon, Christophe; Salaün, Mathieu; Mahieu, Julien; Bubenheim, Michael; Baste, Jean-Marc

    2016-02-01

    Video-assisted thoracic surgery appears to be technically difficult for segmentectomy. Conversely, robotic surgery could facilitate the performance of segmentectomy. The aim of this study was to compare the early results of video- and robot-assisted segmentectomies. Data were collected prospectively on videothoracoscopy from 2010 and on robotic procedures from 2013. Fifty-one patients who were candidates for minimally invasive segmentectomy were included in the study. Perioperative outcomes of video-assisted and robotic segmentectomies were compared. The minimally invasive segmentectomies included 32 video- and 16 robot-assisted procedures; 3 segmentectomies (2 video-assisted and 1 robot-assisted) were converted to lobectomies. Four conversions to thoracotomy were necessary for anatomical reason or arterial injury, with no uncontrolled bleeding in the robotic arm. There were 7 benign or infectious lesions, 9 pre-invasive lesions, 25 lung cancers, and 10 metastatic diseases. Patient characteristics, type of segment, conversion to thoracotomy, conversion to lobectomy, operative time, postoperative complications, chest tube duration, postoperative stay, and histology were similar in the video and robot groups. Estimated blood loss was significantly higher in the video group (100 vs. 50 mL, p = 0.028). The morbidity rate of minimally invasive segmentectomy was low. The short-term results of video-assisted and robot-assisted segmentectomies were similar, and more data are required to show any advantages between the two techniques. Long-term oncologic outcomes are necessary to evaluate these new surgical practices. © The Author(s) 2016.

  19. Karolinska prostatectomy: a robot-assisted laparoscopic radical prostatectomy technique.

    Science.gov (United States)

    Nilsson, Andreas E; Carlsson, Stefan; Laven, Brett A; Wiklund, N Peter

    2006-01-01

    The last decade has witnessed an increasing trend towards minimally invasive management of prostate cancer, including laparoscopic and, more recently, robot-assisted laparoscopic prostatectomy. Several different laparoscopic approaches have been continuously developed during the last 5 years and it is still unclear which technique yields the best outcome. We present our current technique of robot-assisted laparoscopic radical prostatectomy. The technique described has evolved during the course of >400 robotic prostatectomies performed by the robotic team since the robot-assisted laparoscopic radical prostatectomy program was introduced at Karolinska University Hospital in January 2002. Our procedure comprises several modifications of previously reported ones, and we utilize fewer robotic instruments to reduce costs. An extended posterior dissection is performed to aid in the bladder neck-sparing dissection. In nerve-sparing procedures the vesicles are divided to avoid damage to the erectile nerves. In order to preserve the apical anatomy the dorsal venous complex is incised sharply and is first over-sewn after the apical dissection is completed. Our technique enables a more fluent dissection than previously described robotic techniques. Minimizing changes of instruments and the camera not only cuts costs but also reduces inefficient operating maneuvers, such as switching between 30 degrees and 0 degrees lenses during the procedure. We present a technique which in our hands has achieved excellent functional and oncological results.

  20. Robotic-assisted laparoscopic management of a caliceal diverticular calculus

    Science.gov (United States)

    Torricelli, Fabio Cesar Miranda; Batista, Lucas T; Colombo, Jose Roberto; Coelho, Rafael Ferreira

    2014-01-01

    Purpose To report the first case of robotic-assisted laparoscopic management of a symptomatic caliceal diverticular calculus and review the literature on laparoscopic treatment for this condition. Case report A 33-year-old obese woman with a 2×1 cm calculus within an anterior caliceal diverticulum located in the middle pole of the left kidney was referred to our service. She had already undergone two flexible ureterorenoscopies without success. We considered that a percutaneous approach would be very challenging due to stone location, thus we elected to perform a robotic-assisted laparoscopic procedure for stone removal and diverticulum fulguration. The procedure was uneventfully performed with no intraoperative or postoperative complications. The patient was discharged from the hospital on the second postoperative day and after 1.5 years of follow-up she is asymptomatic with no recurrence. Conclusions The robotic-assisted laparoscopic approach to caliceal diverticular calculi is feasible and safe, providing one more option for treatment of stones in challenging locations. PMID:25188925

  1. Robot-assisted radical prostatectomy in Brazil: preliminary results

    Directory of Open Access Journals (Sweden)

    Jose Roberto Colombo Junior

    2009-12-01

    Full Text Available Purpose: To report the initial experience on robot-assisted radical prostatectomy in Brazil. Methods: From March 2008 to March 2009, a hundred patients were treated with robot-assisted radical prostatectomy. Patient’s demographic data, as well as perioperative results of the procedures, are described in this study. Rresults: Patients’ mean age and mean PSA were 58 years and 7.58 ng/ml, respectively. All procedures were performed through transperitoneal approach, with a mean bleeding of 480 mL and surgical time of 298 minutes. A surgical margin affected by cancer was present in 16% of the cases. There were four complications: bleeding requiring transfusion (two cases, rectal perforation corrected on the spot and inadequate functioning of the robot. There was no conversion to another access or obit occurrences in this caseload. Cconclusions: Robot-assisted prostatectomy is a reality in Brazil and the results herein presented demonstrate that this procedure can be safely performed. Long-term follow-up is still necessary to assess the oncological and functional outcomes.

  2. Robot-assisted surgery: the future is here.

    Science.gov (United States)

    Gerhardus, Diana

    2003-01-01

    According to L. Wiley Nifong, director of robotic surgery at East Carolina University's Brody School of Medicine, "Nationally, only one-fourth of the 15 million surgeries performed each year are done with small incisions or what doctors call 'minimally invasive surgery'." Robots could raise that number substantially (Stark 2002). Currently, healthcare organizations use robot technology for thoracic, abdominal, pelvic, and neurological surgical procedures. Minimally invasive surgery reduces the amount of inpatient hospital days, and the computer in the system filters any hand tremors a physician may have during the surgery. The use of robot-assisted surgery improves quality of care because the patient experiences less pain after the surgery. Robot-assisted surgery demonstrates definite advantages for the patient, physician, and hospital; however, healthcare organizations in the United States have yet to acquire the technology because of implementation costs and the lack of FDA (Food and Drug Administration) approval for using the technology for certain types of heart procedures. This article focuses on robot-assisted surgery advantages to patients, physicians, and hospitals as well as on the disadvantages to physicians. In addition, the article addresses implementation costs, which creates financial hurdles for most healthcare organizations; offers recommendations for administrators to embrace this technology for strategic positioning; and enumerates possible roles for robots in medicine.

  3. Robotic-assisted partial Nephrectomy: initial experience in South America

    Directory of Open Access Journals (Sweden)

    Gustavo C. Lemos

    2011-08-01

    Full Text Available OBJECTIVE:To report the initial outcomes of robotic-assisted partial nephrectomy in a tertiary center in South America. MATERIAL AND METHODS: From 11/2008 to 12/2009, a total of 16 transperitoneal robotic-assisted partial nephrectomies were performed in 15 patients to treat 18 kidney tumors. One patient with bilateral tumor had two procedures, while two patients with two synchronous unilateral tumors had a single operation to remove them. Eleven (73% patients were male and the right kidney was affected in 7 (46% patients. The median patient age and tumor size were 57 years old and 30 mm, respectively. Five (28% tumors were hilar and/or centrally located. RESULTS: The median operative time, warm ischemia time and estimated blood loss was 140 min, 27 min and 120 mL, respectively. Blood transfusion was required in one patient with bilateral tumor, and one additional pyelolithotomy was performed due to a 15mm stone located in the renal pelvis. The histopathology analysis showed 15 (83% malignant tumors, which 10 (67% were clear cell carcinoma. The median hospital stay was 72 hrs and no major complication was observed. CONCLUSION: Robotic-assisted partial nephrectomy is safe and represents a valuable option to perform minimally invasive nephron-sparing surgery.

  4. Upper limb robot-assisted therapy in cerebral palsy: a single-blind randomized controlled trial.

    Science.gov (United States)

    Gilliaux, Maxime; Renders, Anne; Dispa, Delphine; Holvoet, Dominique; Sapin, Julien; Dehez, Bruno; Detrembleur, Christine; Lejeune, Thierry M; Stoquart, Gaëtan

    2015-02-01

    Several pilot studies have evoked interest in robot-assisted therapy (RAT) in children with cerebral palsy (CP). To assess the effectiveness of RAT in children with CP through a single-blind randomized controlled trial. Sixteen children with CP were randomized into 2 groups. Eight children performed 5 conventional therapy sessions per week over 8 weeks (control group). Eight children completed 3 conventional therapy sessions and 2 robot-assisted sessions per week over 8 weeks (robotic group). For both groups, each therapy session lasted 45 minutes. Throughout each RAT session, the patient attempted to reach several targets consecutively with the REAPlan. The REAPlan is a distal effector robot that allows for displacements of the upper limb in the horizontal plane. A blinded assessment was performed before and after the intervention with respect to the International Classification of Functioning framework: body structure and function (upper limb kinematics, Box and Block test, Quality of Upper Extremity Skills Test, strength, and spasticity), activities (Abilhand-Kids, Pediatric Evaluation of Disability Inventory), and participation (Life Habits). During each RAT session, patients performed 744 movements on average with the REAPlan. Among the variables assessed, the smoothness of movement (P robotic group than in the control group. This single-blind randomized controlled trial provides the first evidence that RAT is effective in children with CP. Future studies should investigate the long-term effects of this therapy. © The Author(s) 2014.

  5. Active MRI tracking for robotic assisted FUS

    Science.gov (United States)

    Xiao, Xu; Huang, Zhihong; Melzer, Andreas

    2017-03-01

    MR guided FUS is a noninvasive method producing thermal necrosis at the position of tumors with high accuracy and temperature control. Because the typical size of the ultrasound focus is smaller than the area of interested treatment tissues, focus repositioning become necessary to achieve multiple sonications to cover the whole targeted area. Using MR compatible mechanical actuators could help the ultrasound beam to reach a wider treatment range than using electrical beam steering technique and more flexibility in position the transducer. An active MR tracking technique was combined into the MRgFUS system to help locating the position of the mechanical actuator and the FUS transducer. For this study, a precise agar reference model was designed and fabricated to test the performance of the active tracking technique when it was used on the MR-compatible robotics InnoMotion™ (IBSMM, Engineering spol. s r.o. / Ltd, Czech Republic). The precision, tracking range and positioning speed of the combined robotic FUS system were evaluated in this study. Compared to the existing MR guided HIFU systems, the combined robotic system with active tracking techniques provides a potential that allows the FUS treatment to operate in a larger spatial range and with a faster speed, which is one of the main challenges for organ motion tracking.

  6. Robot-assisted training for heart failure patients - a small pilot study.

    Science.gov (United States)

    Schoenrath, Felix; Markendorf, Susanne; Brauchlin, Andreas Emil; Frank, Michelle; Wilhelm, Markus Johannes; Saleh, Lanja; Riener, Robert; Schmied, Christian Marc; Falk, Volkmar

    2015-12-01

    The objective of this study was assess robot-assisted gait therapy with the Lokomat® system in heart failure patients. Patients (n = 5) with stable heart failure and a left ventricular ejection fraction of less than 45% completed a four-week aerobic training period with three trainings per week and an integrated dynamic resistance training of the lower limbs. Patients underwent testing of cardiac and inflammatory biomarkers. A cardiopulmonary exercise test, a quality of life score and an evaluation of the muscular strength by measuring the peak quadriceps force was performed. No adverse events occurred. The combined training resulted in an improvement in peak work rate (range: 6% to 36%) and peak quadriceps force (range: 3% to 80%) in all participants. Peak oxygen consumption (range: –3% to + 61%) increased in three, and oxygen pulse (range: –7% to + 44%) in four of five patients. The quality of life assessment indicated better well-being in all participants. NT-ProBNP (+233 to –733 ng/ml) and the inflammatory biomarkers (hsCRP and IL6) decreased in four of five patients (IL 6: +0.5 to –2 mg/l, hsCRP: +0.2 to –6.5 mg/l). Robot-assisted gait therapy with the Lokomat® System is feasible in heart failure patients and was safe in this trial. The combined aerobic and resistance training intervention with augmented feedback resulted in benefits in exercise capacity, muscle strength and quality of life, as well as an improvement of cardiac (NT-ProBNP) and inflammatory (IL6, hsCRP) biomarkers. Results can only be considered as preliminary and need further validation in larger studies. (ClinicalTrials.gov number, NCT 02146196)

  7. A Dynamic Non Energy Storing Guidance Constraint with Motion Redirection for Robot Assisted Surgery

    Science.gov (United States)

    2016-12-01

    move during the operation. Robot -assisted beating heart surgery is an example of procedures that can benefit from dynamic constraints. Their...A Dynamic Non-Energy-Storing Guidance Constraint with Motion Redirection for Robot -Assisted Surgery Nima Enayati, Eva C. Alves Costa, Giancarlo...Momi, and G. Ferrigno, “Haptics in Robot -Assisted Surgery : Challenges and Benefits,” IEEE Rev. Biomed. Eng., 2016. [2] L. B. Rosenberg, “Virtual

  8. Robot-assisted gastroesophageal surgery: usefulness and limitations.

    Science.gov (United States)

    Diez Del Val, Ismael; Martinez Blazquez, Cándido; Loureiro Gonzalez, Carlos; Vitores Lopez, Jose Maria; Sierra Esteban, Valentin; Barrenetxea Asua, Julen; Del Hoyo Aretxabala, Izaskun; Perez de Villarreal, Patricia; Bilbao Axpe, Jose Esteban; Mendez Martin, Jaime Jesus

    2014-06-01

    Robot-assisted surgery overcomes some of the limitations of traditional laparoscopic surgery. We present our experience and lessons learned in two surgical units dedicated to gastro-esophageal surgery. From June 2009 to January 2013, we performed 130 robot-assisted gastroesophageal procedures, including Nissen fundoplication (29), paraesophageal hernia repair (18), redo for failed antireflux surgery (11), esophagectomy (19), subtotal (5) or wedge (4) gastrectomy, Heller myotomy for achalasia (22), gastric bypass for morbid obesity (12), thoracoscopic leiomyomectomy (4), Morgagni hernia repair (3), lower-third esophageal diverticulectomy (1) and two diagnostic procedures. There were 80 men and 50 women with a median age of 54 years (interquartile range: 46-65). Ten patients (7.7 %) had severe postoperative complications: eight after esophagectomy (three leaks-two cervical and one thoracic-managed conservatively), one stapler failure, one chylothorax, one case of gastric migration to the thorax, one case of biliary peritonitis, and one patient with a transient ventricular dyskinesia. One redo procedure needed reoperation because of port-site bleeding, and one patient died of pulmonary complications after a giant paraesophageal hernia repair; 30-day mortality was, therefore, 0.8 %. There were six elective and one forced conversions (hemorrhage), so total conversion was 5.4 %. Median length of stay was 4 days (IQ range 3-7). Robot-assisted gastroesophageal surgery is feasible and safe, and may be applied to most common procedures. It seems of particular value for Heller myotomy, large paraesophageal hernias, redo antireflux surgery, transhiatal dissection, and hand-sewn intrathoracic anastomosis.

  9. Laparoscopic robot-assisted pancreas transplantation: first world experience.

    Science.gov (United States)

    Boggi, Ugo; Signori, Stefano; Vistoli, Fabio; D'Imporzano, Simone; Amorese, Gabriella; Consani, Giovanni; Guarracino, Fabio; Marchetti, Piero; Focosi, Daniele; Mosca, Franco

    2012-01-27

    Surgical complications are a major disincentive to pancreas transplantation, despite the undisputed benefits of restored insulin independence. The da Vinci surgical system, a computer-assisted electromechanical device, provides the unique opportunity to test whether laparoscopy can reduce the morbidity of pancreas transplantation. Pancreas transplantation was performed by robot-assisted laparoscopy in three patients. The first patient received a pancreas after kidney transplant, the second a simultaneous pancreas kidney transplantation, and the third a pancreas transplant alone. Operations were carried out through an 11-mm optic port, two 8-mm operative ports, and a 7-cm midline incision. The latter was used to introduce the grafts, enable vascular cross-clamping, and create exocrine drainage into the jejunum. The two solitary pancreas transplants required an operating time of 3 and 5 hr, respectively; the simultaneous pancreas kidney transplantation took 8 hr. Mean warm ischemia time of the pancreas graft was 34 min. All pancreatic transplants functioned immediately, and all recipients became insulin independent. The kidney graft, revascularized after 35 min of warm ischemia, also functioned immediately. No patient had complications during or after surgery. At the longer follow-up of 10, 8, and 6 months, respectively, all recipients are alive with normal graft function. We have shown the feasibility of laparoscopic robot-assisted solitary pancreas and simultaneous pancreas and kidney transplantation. If the safety and feasibility of this procedure can be confirmed by larger series, laparoscopic robot-assisted pancreas transplantation could become a new option for diabetic patients needing beta-cell replacement.

  10. Robotic assisted radical prostatectomy: a different treatment for prostate cancer?

    Directory of Open Access Journals (Sweden)

    Alexandre Den Julio

    2010-09-01

    Full Text Available Considering the Health Care System in Brazil, a developing country,and public healthcare policies, robotic surgery is a reality to veryfew citizens. Therefore, robotic assisted radical prostatectomy isfar removed from the daily practice of the vast majority of Brazilianurologists. Scientific evidence of the superiority of robotic assistedradical prostatectomy does not presently justify public investmentsfor widespread development of robotic centers. Maybe over timeand with reductions in costs, robotic technology will become amore established practice, as observed in other countries, and morefeasible for the Brazilian urological community.

  11. Robot-Assisted Training Early After Cardiac Surgery.

    Science.gov (United States)

    Schoenrath, Felix; Markendorf, Susanne; Brauchlin, Andreas E; Seifert, Burkhardt; Wilhelm, Markus J; Czerny, Martin; Riener, Robert; Falk, Volkmar; Schmied, Christian M

    2015-07-01

    To assess feasibility and safety of a robot-assisted gait therapy with the Lokomat® system in patients early after open heart surgery. Within days after open heart surgery 10 patients were subjected to postoperative Lokomat® training (Intervention group, IG) whereas 20 patients served as controls undergoing standard postoperative physiotherapy (Control group, CG). All patients underwent six-minute walk test and evaluation of the muscular strength of the lower limbs by measuring quadriceps peak force. The primary safety end-point was freedom from any device-related wound healing disturbance. Patients underwent clinical follow-up after one month. Both training methods resulted in an improvement of walking distance (IG [median, interquartile range, p-value]: +119 m, 70-201 m, p = 0.005; CG: 105 m, 57-152.5m, p force (IG left: +5 N, 3.8 7 N, p = 0.005; IG right: +3.5 N, 1.5-8.8 N, p = 0.011; CG left: +5.5 N, 4-9 N, p training were comparable to early postoperative standard in hospital training (median changes in walking distance in percent, p = 0.81; median changes in quadriceps peak force in percent, left: p = 0.97, right p = 0.61). No deep sternal wound infection or any adverse event occurred in the robot-assisted training group. Robot-assisted gait therapy with the Lokomat® system is feasible and safe in patients early after median sternotomy. Results with robot-assisted training were comparable to standard in hospital training. An adapted and combined aerobic and resistance training intervention with augmented feedback may result in benefits in walking distance and lower limb muscle strength (ClinicalTrials.gov number, NCT 02146196). © 2015 Wiley Periodicals, Inc.

  12. The reach and adoption of a coach-led exercise training programme in community football.

    Science.gov (United States)

    Finch, Caroline F; Diamantopoulou, Kathy; Twomey, Dara M; Doyle, Tim L A; Lloyd, David G; Young, Warren; Elliott, Bruce C

    2014-04-01

    To determine the reach and adoption of a coach-led exercise training programme for lower limb injury prevention. Secondary analysis of data from a group-clustered randomised controlled trial. A periodised exercise training warm-up programme was delivered to players during training sessions over an 8-week preseason (weeks 1-8) and 18-week playing season. 1564 community Australian football players. Reach, measured weekly, was the number of players who attended training sessions. Adoption was the number of attending players who completed the programme in full, partially or not at all. Reasons for partial or non-participation were recorded. In week 1, 599 players entered the programme; 55% attended 1 training session and 45% attended > 1 session. By week 12, 1540 players were recruited but training attendance (reach) decreased to <50%. When players attended training, the majority adopted the full programme-ranging from 96% (week 1) to above 80% until week 20. The most common reasons for low adoption were players being injured, too sore, being late for training or choosing their own warm-up. The training programme's reach was highest preseason and halved at the playing season's end. However, when players attended training sessions, their adoption was high and remained close to 70% by season end. For sports injury prevention programmes to be fully effective across a season, attention also needs to be given to (1) encouraging players to attend formal training sessions and (2) considering the possibility of some form of programme delivery outside of formal training.

  13. Virtual modeling of robot-assisted manipulations in abdominal surgery.

    Science.gov (United States)

    Berelavichus, Stanislav V; Karmazanovsky, Grigory G; Shirokov, Vadim S; Kubyshkin, Valeriy A; Kriger, Andrey G; Kondratyev, Evgeny V; Zakharova, Olga P

    2012-06-27

    To determine the effectiveness of using multidetector computed tomography (MDCT) data in preoperative planning of robot-assisted surgery. Fourteen patients indicated for surgery underwent MDCT using 64 and 256-slice MDCT. Before the examination, a specially constructed navigation net was placed on the patient's anterior abdominal wall. Processing of MDCT data was performed on a Brilliance Workspace 4 (Philips). Virtual vectors that imitate robotic and assistant ports were placed on the anterior abdominal wall of the 3D model of the patient, considering the individual anatomy of the patient and the technical capabilities of robotic arms. Sites for location of the ports were directed by projection on the roentgen-positive tags of the navigation net. There were no complications observed during surgery or in the post-operative period. We were able to reduce robotic arm interference during surgery. The surgical area was optimal for robotic and assistant manipulators without any need for reinstallation of the trocars. This method allows modeling of the main steps in robot-assisted intervention, optimizing operation of the manipulator and lowering the risk of injuries to internal organs.

  14. [Robotic assistance in gynaecological surgery: State-of-the-art].

    Science.gov (United States)

    Monsarrat, N; Collinet, P; Narducci, F; Leblanc, E; Vinatier, D

    2009-05-01

    From the Automated Endoscopic System for Optimal Positioning (AESOP), a robotic arm which operates the laparoscope, to the robots Zeus and da Vinci, robotic assistance in gynaecological endoscopic surgery has continuously evolved for the last fifteen years or so. It has brought about new technical advancements: the last generation robots offer a steady three-dimensional image, improved instrument dexterity and precision, higher ergonomics and comfort for the surgeon. The da Vinci robotic system has been used without evincing any specific morbidity in various cases, notably for tubal reanastomosis, myomectomy, hysterectomy, pelvic and para-aortic lymphadenectomy or sacrocolpopexy amongst others. Robotic assistance in gynaecology is thus feasible. Like conventional laparoscopic surgery, it allows decreased blood loss and morbidity as well as shorter hospital stay, as compared to laparotomy. It might indeed allow many surgical teams to perform minimally invasive surgical procedures which they were not used to performing by laparoscopy. Randomized prospective studies are needed to define its indications more precisely. Besides, its medico-financial impact should be evaluated too.

  15. Toward the art of robotic-assisted vitreoretinal surgery

    Directory of Open Access Journals (Sweden)

    Amir Molaei

    2017-01-01

    Full Text Available New technological progress in robotics has brought many beneficial clinical applications. Currently, computer integrated robotic surgery has gained clinical acceptance for several surgical procedures. Robotically assisted eye surgery is envisaged as a promising solution to overcome the shortcomings inherent to conventional surgical procedures as in vitreoretinal surgeries. Robotics by its high precision and fine mechanical control can improve dexterity, cancel tremor, and allow highly precise remote surgical capability, delicate vitreoretinal manipulation capabilities. Combined with magnified three-dimensional imaging of the surgical site, it can enhance surgical precision. Tele-manipulation can provide the ability for tele-surgery or haptic feedback of forces generated by the manipulation of intraocular tissues. It presents new solutions for some sight-threatening conditions such as retinal vein cannulation where, due to physiological limitations of the surgeon's hand, the procedure cannot be adequately performed. In this paper, we provide an overview of the research and advances in robotically assisted vitreoretinal eye surgery. Additionally the barriers to the integration of this method in the field of ocular surgery are summarized. Finally, we discuss the possible applications of the method in the area of vitreoretinal surgery.

  16. A Perspective on Robotic Assistance for Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Nathan A. Netravali

    2013-01-01

    Full Text Available Knee arthroplasty is used to treat patients with degenerative joint disease of the knee to reduce pain and restore the function of the joint. Although patient outcomes are generally quite good, there are still a number of patients that are dissatisfied with their procedures. Aside from implant design which has largely become standard, surgical technique is one of the main factors that determine clinical results. Therefore, a lot of effort has gone into improving surgical technique including the use of computer-aided surgery. The latest generation of orthopedic surgical tools involves the use of robotics to enhance the surgeons’ abilities to install implants more precisely and consistently. This review presents an evolution of robot-assisted surgical systems for knee replacement with an emphasis on the clinical results available in the literature. Ever since various robotic-assistance systems were developed and used clinically worldwide, studies have demonstrated that these systems are as safe as and more accurate than conventional methods of manual implantation. Robotic surgical assistance will likely result in improved surgical technique and improved clinical results.

  17. [Laser-based quality assurance for robot-assisted milling at the base of the skull].

    Science.gov (United States)

    Maassen, M M; Malthan, D; Stallkamp, J; Schäfer, A; Dammann, F; Schwaderer, E; Zenner, H P

    2006-02-01

    Implanting active hearing devices in the lateral base of the skull requires high-precision, secure fixation of the electromagnetic transducer and long-life anchorage using osteosynthetic fixation plates referred to as mountain brackets. Nonlinear distortion in the acoustic signal path and consecutive implant loosening can only be avoided by exact osseous milling to create the necessary cavity bed while avoiding excessive milling. Robot technology is ideal for high-precision milling. However, safety measures are necessary in order to prevent errors from occurring during the reduction process. Ideally, a robot should be guided by a navigation system. However, robotic systems so far available do not yet have an integrated global navigation system. We used an animal model under laboratory conditions to examine the extent to which the semiautomatic ROBIN assistant system developed could be expected to increase osseous milling accuracy before implanting active electronic hearing devices into the recipient tissue in the cranium. An existing prototype system for robot-assisted skull base surgery was equipped with laser sensors for geometric measurement of the operation site. The three-dimensional measurement data was compared with CT simulation data before, during, and after the robot-assisted operation. The experiments were conducted on test objects as well as on animal models. Under ideal conditions, the operation site could be measured at a spatial resolution of better than 0.02 mm in each dimension. However, reflections and impurities in the operation site from bleeding and rinsing fluids did have a considerable effect on data collection, necessitating specialised registering procedures. Using an error-tolerant procedure specifically developed, the effective registering error could be kept under 0.3 mm. After milling, the resulting shape matched the intended form at an accuracy level of 0.8 mm. The results show that robot systems can reach the accuracy required for

  18. Possible benefits of robot-assisted rectal cancer surgery regarding urological and sexual dysfunction

    DEFF Research Database (Denmark)

    Broholm Andersen, Malene; Pommergaard, H-C; Gögenür, I

    2015-01-01

    AIM: Robot-assisted surgery for rectal cancer may result in lower rates of urogenital dysfunction compared with laparoscopic surgery. A systematic review was conducted of studies reporting urogenital dysfunction after robot-assisted rectal cancer surgery. METHOD: PubMed, Embase and the Cochrane...... Library were systematically searched in February 2014. All studies investigating urogenital function after robot-assisted rectal cancer surgery were identified. The inclusion criteria for meta-analysis studies required comparison of robot-assisted with laparoscopic surgery and the evaluation of urological...... to four including 152 patients in the robotic group and 161 in the laparoscopic group, without heterogeneity. The IPSS score at 3 and 12 months favoured robot-assisted surgery [mean difference (MD) -1.58; 95% CI (-3.1, -0.0), [P = 0.04; and MD -0.90 (-1.81, -0.02), P = 0.05]. IIEF scores at 3 months...

  19. Instrumental tactile diagnostics in robot-assisted surgery

    Directory of Open Access Journals (Sweden)

    Solodova RF

    2016-10-01

    Full Text Available Rozalia F Solodova,1,2 Vladimir V Galatenko,1,2 Eldar R Nakashidze,3 Igor L Andreytsev,3 Alexey V Galatenko,1 Dmitriy K Senchik,2 Vladimir M Staroverov,1 Vladimir E Podolskii,1,2 Mikhail E Sokolov,1,2 Victor A Sadovnichy1,2 1Faculty of Mechanics and Mathematics, 2Institute of Mathematical Studies of Complex Systems, Lomonosov Moscow State University, 31st Surgery Department, Clinical Hospital 31, Moscow, Russia Background: Robotic surgery has gained wide acceptance due to minimizing trauma in patients. However, the lack of tactile feedback is an essential limiting factor for the further expansion. In robotic surgery, feedback related to touch is currently kinesthetic, and it is mainly aimed at the minimization of force applied to tissues and organs. Design and implementation of diagnostic tactile feedback is still an open problem. We hypothesized that a sufficient tactile feedback in robot-assisted surgery can be provided by utilization of Medical Tactile Endosurgical Complex (MTEC, which is a novel specialized tool that is already commercially available in the Russian Federation. MTEC allows registration of tactile images by a mechanoreceptor, real-time visualization of these images, and reproduction of images via a tactile display. Materials and methods: Nine elective surgeries were performed with da Vinci™ robotic system. An assistant performed tactile examination through an additional port under the guidance of a surgeon during revision of tissues. The operating surgeon sensed registered tactile data using a tactile display, and the assistant inspected the visualization of tactile data. First, surgeries where lesion boundaries were visually detectable were performed. The goal was to promote cooperation between the surgeon and the assistant and to train them in perception of the tactile feedback. Then, instrumental tactile diagnostics was utilized in case of visually undetectable boundaries. Results: In robot-assisted surgeries where lesion

  20. Percutaneous Sacroiliac Screw Placement: A Prospective Randomized Comparison of Robot-assisted Navigation Procedures with a Conventional Technique

    Directory of Open Access Journals (Sweden)

    Jun-Qiang Wang

    2017-01-01

    Conclusions: Accuracy of the robot-assisted technique was superior to that of the freehand technique. Robot-assisted navigation is safe for unstable posterior pelvic ring stabilization, especially in S1, but also in S2. SI screw insertion with robot-assisted navigation is clinically feasible.

  1. Robot-assisted partial nephrectomy in contemporary practice

    Energy Technology Data Exchange (ETDEWEB)

    Tanagho, Youssef S.; Bhayani, Sam B.; Figenshau, Robert S., E-mail: tanaghoy@wudosis.wustl.edu [Division of Urologic Surgery, Washington University School of Medicine, St. Louis, MO (United States)

    2013-01-11

    Laparoscopic renal surgery is associated with reduced blood loss, shorter hospital stay, enhanced cosmesis, and more rapid convalescence relative to open renal surgery. Laparoscopic partial nephrectomy (LPN) is a minimally invasive, nephron-sparing alternative to laparoscopic radical nephrectomy (RN) for the management of small renal masses. While offering similar oncological outcomes to laparoscopic RN, the technical challenges and prolonged learning curve associated with LPN limit its wider dissemination. Robot-assisted partial nephrectomy (RAPN), although still an evolving procedure with no long-term data, has emerged as a viable alternative to LPN, with favorable preliminary outcomes. This article provides an overview of the role of RAPN in the management of renal cell carcinoma. The clinical indications and principles of surgical technique for this procedure are discussed. The oncological, renal functional, and perioperative outcomes of RAPN are also evaluated, as are complication rates.

  2. Anesthetic management of robot-assisted thoracoscopic thymectomy

    Directory of Open Access Journals (Sweden)

    Anil Karlekar

    2016-01-01

    Full Text Available Myasthenia gravis (MG is a rare disorder involving neuromuscular junction. In conjunction with medical therapy, thymectomy is a known modality of treatment of MG and has shown to increase the probability of remission and overall symptomatic improvement. For minimally invasive thymectomy, video-.assisted thoracoscopic surgery has been the preferred surgical approach till recently. The robotic surgical procedure must necessarily bring new challenges to the anesthesiologists to effectively meet the specific requirements of the technique. At present, there is a paucity of literature regarding the anesthetic concerns of robotic assisted thymectomy, patient in question specifically posed a challenge since different maneuvers and techniques had to be tried to obtain optimum surgical conditions with stable ventilatory and hemodynamic parameters. Concerns of patient positioning and hemodynamic monitoring have also been discussed.

  3. Robot-assisted partial nephrectomy in contemporary practice

    International Nuclear Information System (INIS)

    Tanagho, Youssef S.; Bhayani, Sam B.; Figenshau, Robert S.

    2013-01-01

    Laparoscopic renal surgery is associated with reduced blood loss, shorter hospital stay, enhanced cosmesis, and more rapid convalescence relative to open renal surgery. Laparoscopic partial nephrectomy (LPN) is a minimally invasive, nephron-sparing alternative to laparoscopic radical nephrectomy (RN) for the management of small renal masses. While offering similar oncological outcomes to laparoscopic RN, the technical challenges and prolonged learning curve associated with LPN limit its wider dissemination. Robot-assisted partial nephrectomy (RAPN), although still an evolving procedure with no long-term data, has emerged as a viable alternative to LPN, with favorable preliminary outcomes. This article provides an overview of the role of RAPN in the management of renal cell carcinoma. The clinical indications and principles of surgical technique for this procedure are discussed. The oncological, renal functional, and perioperative outcomes of RAPN are also evaluated, as are complication rates.

  4. Transoral robotic assisted resection of the parapharyngeal space.

    Science.gov (United States)

    Mendelsohn, Abie H

    2015-02-01

    Preliminary case series have reported clinical feasibility and safety of a transoral minimally invasive technique to approach parapharyngeal space masses. With the assistance of the surgical robotic system, tumors within the parapharyngeal space can now be excised safely without neck incisions. A detailed technical description is included. After developing compressive symptoms from a parapharyngeal space lipomatous tumor, the patient was referred by his primary otolaryngologist because of poor open surgical access to the nasopharyngeal component of the tumor. Transoral robotic assisted resection of a 54- × 46-mm parapharyngeal space mass was performed, utilizing 97 minutes of robotic surgical time. Pictorial demonstration of the robotic resection is provided. Parapharyngeal space tumors have traditionally been approached via transcervical skin incisions, typically including blunt dissection from tactile feedback. The transoral robotic approach offers magnified 3D visualization of the parapharyngeal space that allows for complete and safe resection. © 2014 Wiley Periodicals, Inc.

  5. Robotic-Assisted Live Donor Ileal Segmentectomy for Intestinal Transplantation

    Directory of Open Access Journals (Sweden)

    Guosheng Wu, MD, PhD

    2017-10-01

    Full Text Available Background. Every effort should be made to optimize surgical techniques and to minimize potential morbidity rates associated with live donor operations. Advances in a minimally invasive approach by robotic surgery to donor nephrectomy have raised the possibility of applying this technique to live donor bowel resections for intestinal transplantation. Methods. We report the first 5 consecutive cases of a robotic-assisted live donor ileal segmentectomy. We describe the technical aspects of the procedure, discuss the rationale for considering this option, and evaluate potential advantages of this approach. Results. We found that this new approach is associated with less postoperative discomfort, a shorter hospital length of stay, and a faster recovery of bowel function compared to our previous open surgery. Conclusions. Our initial experience suggests that robotic surgery is a safe and feasible procedure for live donor ileal resection for intestinal transplantation and is a useful alternative to conventional open surgery.

  6. Robotic-Assisted Unicompartmental Knee Arthroplasty: State-of-the Art and Review of the Literature.

    Science.gov (United States)

    Christ, Alexander B; Pearle, Andrew D; Mayman, David J; Haas, Steven B

    2018-03-16

    Unicompartmental knee arthroplasty is a successful treatment for unicompartmental knee osteoarthritis that has lower complication rates, faster recovery, and a more natural feeling knee compared to total knee arthroplasty. However, long-term survival has been a persistent concern. As more surgeon-controlled variables have been linked to survival, interest in robotic-assisted surgery has continued to grow. A review and synthesis of the literature on the subject of robotic-assisted unicompartmental knee arthroplasty was performed. We present the driving factors behind the development of robotic-assisted techniques in unicompartmental knee arthroplasty and the current state-of-the art. The ability of surgeons to achieve intraoperative targets with robotic assistance and the outcomes of robotic-assisted surgery are also described. Robotic-assisted surgery has become increasingly popular in unicompartmental knee arthroplasty, as it allows surgeons to more accurately and reproducibly plan and achieve operative targets during surgery. Cost remains a concern, and it remains to be seen whether robotic-assisted surgery will improve long-term survivorship after unicompartmental knee arthroplasty. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. A Systematic Review of Virtual Reality Simulators for Robot-assisted Surgery.

    Science.gov (United States)

    Moglia, Andrea; Ferrari, Vincenzo; Morelli, Luca; Ferrari, Mauro; Mosca, Franco; Cuschieri, Alfred

    2016-06-01

    No single large published randomized controlled trial (RCT) has confirmed the efficacy of virtual simulators in the acquisition of skills to the standard required for safe clinical robotic surgery. This remains the main obstacle for the adoption of these virtual simulators in surgical residency curricula. To evaluate the level of evidence in published studies on the efficacy of training on virtual simulators for robotic surgery. In April 2015 a literature search was conducted on PubMed, Web of Science, Scopus, Cochrane Library, the Clinical Trials Database (US) and the Meta Register of Controlled Trials. All publications were scrutinized for relevance to the review and for assessment of the levels of evidence provided using the classification developed by the Oxford Centre for Evidence-Based Medicine. The publications included in the review consisted of one RCT and 28 cohort studies on validity, and seven RCTs and two cohort studies on skills transfer from virtual simulators to robot-assisted surgery. Simulators were rated good for realism (face validity) and for usefulness as a training tool (content validity). However, the studies included used various simulation training methodologies, limiting the assessment of construct validity. The review confirms the absence of any consensus on which tasks and metrics are the most effective for the da Vinci Skills Simulator and dV-Trainer, the most widely investigated systems. Although there is consensus for the RoSS simulator, this is based on only two studies on construct validity involving four exercises. One study on initial evaluation of an augmented reality module for partial nephrectomy using the dV-Trainer reported high correlation (r=0.8) between in vivo porcine nephrectomy and a virtual renorrhaphy task according to the overall Global Evaluation Assessment of Robotic Surgery (GEARS) score. In one RCT on skills transfer, the experimental group outperformed the control group, with a significant difference in overall

  8. Robotic-assisted vesicovaginal fistula repair using an extravesical approach without interposition grafting.

    Science.gov (United States)

    Kelly, Erin; Wu, Maria Y; MacMillan, J Barry

    2018-03-01

    Post-hysterectomy vesicovaginal fistula (VVF) is rare. In addition to conventional abdominal and vaginal approaches, robotic-assisted VVF repairs have recently been described. We present a case of an extravesical, robotic-assisted VVF repair, without placement of an interposition graft performed in a Canadian teaching center. A 51-year-old woman presented with urinary incontinence 5 days after laparoscopic hysterectomy. Computed tomography cystogram, cystoscopy, and methylene blue dye test, confirmed a VVF above the bladder trigone. The patient underwent a robotic-assisted VVF repair 3 months after presentation, without complication. An abdominal, extravesical approach was used. Operative time was 116 min and repeat CT cystogram showed no evidence of persistent. We have demonstrated that a VVF repair, using a robotic-assisted, extravesical approach without interposition graft placement, can be safe, less invasive and have a successful outcome at 1 year of follow-up.

  9. Robot-assisted tubal reanastomosis: Initial experience in a single institution

    Directory of Open Access Journals (Sweden)

    Ahmet Göçmen

    2013-03-01

    Conclusion: Robot-assisted TLR is safe and feasible. This procedure may facilitate minimally invasive treatment for patients who want to regain their fertility without the aid of artificial reproductive techniques.

  10. Robot-assisted radiofrequency ablation of primary and secondary liver tumours: early experience

    International Nuclear Information System (INIS)

    Abdullah, Basri Johan Jeet; Yeong, Chai Hong; Goh, Khean Lee; Yoong, Boon Koon; Ho, Gwo Fuang; Yim, Carolyn Chue Wai; Kulkarni, Anjali

    2014-01-01

    Computed tomography (CT)-compatible robots, both commercial and research-based, have been developed with the intention of increasing the accuracy of needle placement and potentially improving the outcomes of therapies in addition to reducing clinical staff and patient exposure to radiation during CT fluoroscopy. In the case of highly inaccessible lesions that require multiple plane angulations, robotically assisted needles may improve biopsy access and targeted drug delivery therapy by avoidance of the straight line path of normal linear needles. We report our preliminary experience of performing radiofrequency ablation of the liver using a robotic-assisted CT guidance system on 11 patients (17 lesions). Robotic-assisted planning and needle placement appears to have high accuracy, is technically easier than the non-robotic-assisted procedure, and involves a significantly lower radiation dose to both patient and support staff. (orig.)

  11. Robot-assisted radiofrequency ablation of primary and secondary liver tumours: early experience

    Energy Technology Data Exchange (ETDEWEB)

    Abdullah, Basri Johan Jeet [University of Malaya, Department of Biomedical Imaging, Faculty of Medicine, Kuala Lumpur (Malaysia); Yeong, Chai Hong [University of Malaya, University of Malaya Research Imaging Centre, Faculty of Medicine, Kuala Lumpur (Malaysia); Goh, Khean Lee [University of Malaya, Department of Internal Medicine, Faculty of Medicine, Kuala Lumpur (Malaysia); Yoong, Boon Koon [University of Malaya, Department of Surgery, Faculty of Medicine, Kuala Lumpur (Malaysia); Ho, Gwo Fuang [University of Malaya, Department of Oncology, Faculty of Medicine, Kuala Lumpur (Malaysia); Yim, Carolyn Chue Wai [University of Malaya, Department of Anesthesia, Faculty of Medicine, Kuala Lumpur (Malaysia); Kulkarni, Anjali [Perfint Healthcare Corporation, Florence, OR (United States)

    2014-01-15

    Computed tomography (CT)-compatible robots, both commercial and research-based, have been developed with the intention of increasing the accuracy of needle placement and potentially improving the outcomes of therapies in addition to reducing clinical staff and patient exposure to radiation during CT fluoroscopy. In the case of highly inaccessible lesions that require multiple plane angulations, robotically assisted needles may improve biopsy access and targeted drug delivery therapy by avoidance of the straight line path of normal linear needles. We report our preliminary experience of performing radiofrequency ablation of the liver using a robotic-assisted CT guidance system on 11 patients (17 lesions). Robotic-assisted planning and needle placement appears to have high accuracy, is technically easier than the non-robotic-assisted procedure, and involves a significantly lower radiation dose to both patient and support staff. (orig.)

  12. ROBOT-ASSISTED SURGERY AND ROBOTS EXOSKELETONS FOR REHABILITATION: WORLD TECHNOLOGICAL LEADERS AND PERSPECTIVES OF RUSSIA

    Directory of Open Access Journals (Sweden)

    O. V. Cherchenko

    2015-01-01

    Full Text Available There was analysed the publication and patent activity with regard to two actively developing areas in the field of medical robototronics: robots-exoskeletons for rehabilitation of people with muscoloskeletal disorders and robot-assisted surgery. There was identified discrepancy in the structure of global and national publication and patent flows. There were revealed disadvantages of foreign innovations on robot-assisted surgery, which create prerequisites for promoting import-substituting innovations of domestic engineers. 

  13. Long-term quality of life and outcomes following robotic assisted TAPP inguinal hernia repair.

    Science.gov (United States)

    Iraniha, Andrew; Peloquin, Joshua

    2018-06-01

    Laparoscopic TAPP inguinal hernia repair is an established alternative to open hernia repair, which offers equivalent outcomes with less postoperative pain and faster recovery. Unfortunately, it remains technically challenging, requiring advanced laparoscopic skills which have limited its popularity among surgeons. The robotic platform has the potential to overcome these challenges. The objective of this study was to examine the long-term quality of life and outcomes following robotic assisted TAPP inguinal hernia repair, since these data have not been reported up to now. From October 2012 to October 2015, 159 inguinal hernias in 82 consecutive patients were repaired with 3D mesh (BARD) using da Vinci Si Surgical System (Intuitive Surgical, Sunnyvale, CA, USA). The patients' demographics and intraoperative data were documented. Patients were seen 2 and 6 weeks after the surgery and the complications were recorded. Patients were assessed 6 weeks after the surgery by a survey using a universal pain assessment tool to document their post-operative pain, narcotic use and time of return to work and exercise. A modified short form 12 (SF 12) was also sent out to the patients 12-36 months after the surgery to measure their health-related quality of life prior to surgery and at the 12- to 36-month follow-up, and to document any evidence of recurrence. Postoperative health-related quality of life scores were compared to the pre-operative baseline quality of life scores using the unpaired t test. Over the course of 3 years, 159 robotic assisted TAPP inguinal hernia repair were performed in 82 patients, 73 men and 9 women by one surgeon as an outpatient basis. The mean age was 53 and mean body mass index was 26. There were no intraoperative complications or conversions. The average operative time was 99 min. Four patients developed urinary retention post-operatively and one patient developed postoperative bowel obstruction requiring laparoscopic lysis of adhesion with no

  14. Fertility and Symptom Relief following Robot-Assisted Laparoscopic Myomectomy

    Directory of Open Access Journals (Sweden)

    Michael C. Pitter

    2015-01-01

    Full Text Available Objective. To examine success of robot-assisted laparoscopic myomectomy (RALM measured by sustained symptom relief and fertility. Methods. This is a retrospective survey of 426 women who underwent RALM for fibroids, symptom relief, or infertility at three practice sites across the US. We examined rates of symptom recurrence and pregnancy and factors associated with these outcomes. Results. Overall, 70% of women reported being symptom-free, with 62.9% free of symptoms after three years. At >3 years, 66.7% of women who underwent surgery to treat infertility and 80% who were also symptom-free reported achieving pregnancy. Factors independently associated with symptom recurrence included greater time after surgery, preoperative dyspareunia, multiple fibroid surgeries, smoking after surgery, and preexisting diabetes. Factors positively correlated with achieving pregnancy included desiring pregnancy, prior pregnancy, greater time since surgery, and Caucasian race. Factors negatively correlated with pregnancy were advanced age and symptom recurrence. Conclusions. This paper, the first to examine symptom recurrence after RALM, demonstrates both short- and long-term effectiveness in providing symptom relief. Furthermore, RALM may have the potential to improve the chance of conception, even in a population at high risk of subfertility, with greater benefits among those who remain symptom-free. These findings require prospective validation.

  15. Robot-Assisted Fracture Surgery: Surgical Requirements and System Design.

    Science.gov (United States)

    Georgilas, Ioannis; Dagnino, Giulio; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2018-03-09

    The design of medical devices is a complex and crucial process to ensure patient safety. It has been shown that improperly designed devices lead to errors and associated accidents and costs. A key element for a successful design is incorporating the views of the primary and secondary stakeholders early in the development process. They provide insights into current practice and point out specific issues with the current processes and equipment in use. This work presents how information from a user-study conducted in the early stages of the RAFS (Robot Assisted Fracture Surgery) project informed the subsequent development and testing of the system. The user needs were captured using qualitative methods and converted to operational, functional, and non-functional requirements based on the methods derived from product design and development. This work presents how the requirements inform a new workflow for intra-articular joint fracture reduction using a robotic system. It is also shown how the various elements of the system are developed to explicitly address one or more of the requirements identified, and how intermediate verification tests are conducted to ensure conformity. Finally, a validation test in the form of a cadaveric trial confirms the ability of the designed system to satisfy the aims set by the original research question and the needs of the users.

  16. Robotic Assisted Transanal Polypectomies: Is There Any Indication?

    Science.gov (United States)

    Gómez Ruiz, Marcos; Cagigas Fernández, Carmen; Alonso Martín, Joaquín; Cristobal Poch, Lidia; Manuel Palazuelos, Carlos; Barredo Cañibano, Francisco Javier; Gómez Fleitas, Manuel; Castillo Diego, Julio

    2017-12-01

    Robotic assisted transanal polipectomy may have advantages compared with the conventional transanal minimally invasive surgery technique. We evaluate the safety, feasibility and advantages of this technique. Between February 2014 and October 2015, 9patients underwent robotic transanal polypectomy. We performed a retrospective study in which we analyse prospectively collected data regarding patient and tumor characteristics, perioperative outcomes, pathological report, morbidity and mortality. A total of 5 male and 4 female patients underwent robotic TAMIS. Lesions were 6,22cm from the anal verge. Mean size was 15,8cm 2 . All procedures were performed in the lithotomy position. Closure of the defect was performed in all cases. Mean blood loss was 39,8ml. Mean operative time was 71,9min. No severe postoperative complications or readmissions occured. Median hospital stay was 2,5 days. Robotic TAMIS is useful to treat complex rectal lesions. Our transanal platform allowed a wider range of movements of the robotic arms and to perform all procedures in the lithotomy position. Copyright © 2017 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Automated robot-assisted surgical skill evaluation: Predictive analytics approach.

    Science.gov (United States)

    Fard, Mahtab J; Ameri, Sattar; Darin Ellis, R; Chinnam, Ratna B; Pandya, Abhilash K; Klein, Michael D

    2018-02-01

    Surgical skill assessment has predominantly been a subjective task. Recently, technological advances such as robot-assisted surgery have created great opportunities for objective surgical evaluation. In this paper, we introduce a predictive framework for objective skill assessment based on movement trajectory data. Our aim is to build a classification framework to automatically evaluate the performance of surgeons with different levels of expertise. Eight global movement features are extracted from movement trajectory data captured by a da Vinci robot for surgeons with two levels of expertise - novice and expert. Three classification methods - k-nearest neighbours, logistic regression and support vector machines - are applied. The result shows that the proposed framework can classify surgeons' expertise as novice or expert with an accuracy of 82.3% for knot tying and 89.9% for a suturing task. This study demonstrates and evaluates the ability of machine learning methods to automatically classify expert and novice surgeons using global movement features. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Robot-Assisted Free Flap in Head and Neck Reconstruction

    Directory of Open Access Journals (Sweden)

    Han Gyeol Song

    2013-07-01

    Full Text Available Background  Robots have allowed head and neck surgeons to extirpate oropharyngealtumors safely without the need for lip-split incision or mandibulotomy. Using robots inoropharyngealreconstruction is newbut essentialfor oropharyngeal defectsthatresultfromrobotic tumor excision. We report our experience with robotic free-flap reconstruction ofhead and neck defectsto exemplify the necessity forrobotic reconstruction.Methods  We investigated head and neck cancer patients who underwent ablation surgeryand free-flap reconstruction by robot. Between July 1, 2011 andMarch 31, 2012, 5 caseswereperformed and patient demographics, location of tumor, pathologic stage, reconstructionmethods, flap size, recipient vessel, necessary pedicle length, and operation time wereinvestigated.Results  Among five free-flap reconstructions, four were radial forearm free flaps and onewas an anterolateral thigh free-flap. Four flaps used the superior thyroid artery and oneflap used a facial artery as the recipient vessel. The average pedicle length was 8.8 cm. Flapinsetting and microanastomosis were achieved using a specially manufactured roboticinstrument. The total operation timewas 1,041.0 minutes(range, 814 to 1,132 minutes, andcomplicationsincluding flap necrosis, hematoma, andwound dehiscence did not occur.Conclusions  Thisstudy demonstratesthe clinically applicable use ofrobotsin oropharyngealreconstruction, especially using a free flap. A robot can assist the operator in insettingthe flap at a deep portion of the oropharynx without the need to perform a traditionalmandibulotomy. Robot-assisted reconstruction may substitute for existing surgical methodsand is accepted asthemost up-to-datemethod.

  19. Robot-assisted laparoscopic (RAL) procedures in general surgery.

    Science.gov (United States)

    Alimoglu, Orhan; Sagiroglu, Julide; Atak, Ibrahim; Kilic, Ali; Eren, Tunc; Caliskan, Mujgan; Bas, Gurhan

    2016-09-01

    Robotics was introduced in clinical practice more than two decades ago, and it has gained remarkable popularity for a wide variety of laparoscopic procedures. We report our results of robot-assisted laparoscopic surgery (RALS) in the most commonly applied general surgical procedures. Ninety seven patients underwent RALS from 2009 to 2012. Indications for RALS were cholelithiasis, gastric carcinoma, splenic tumors, colorectal carcinoma, benign colorectal diseases, non-toxic nodular goiter and incisional hernia. Records of patients were analyzed for demographic features, intraoperative and postoperative complications and conversion to open surgery. Forty six female and 51 male patients were operated and mean age was 58,4 (range: 25-88). Ninety three out of 97 procedures (96%) were completed robotically, 4 were converted to open surgery and there were 15 postoperative complications. There was no mortality. Wide variety of procedures of general surgery can be managed safely and effectively by RALS. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Robotic Assisted Laparoscopic Prostatectomy after High Intensity Focused Ultrasound Failure

    Directory of Open Access Journals (Sweden)

    Leon Telis

    2017-01-01

    Full Text Available Background. Prostate cancer is the most common cancer diagnosed in men. As new focal therapies become more popular in treatment of prostate cancer, failure cases requiring salvage therapy with either surgical or other techniques are being reported. Objective. To report the options in treatment of prostate cancer after recurrence or failure of the primary treatment modality. Methods. We report a salvage robotic assisted laparoscopic radical prostatectomy (RALP for prostate cancer recurrence following high intensity focused ultrasound treatment (HIFU in the United States. Results. A 67-year-old man who underwent HIFU treatment for prostate adenocarcinoma 2 years prior was presented with a rising prostate specific antigen of 6.1 ng/mL to our clinic. A biopsy proven recurrent disease in the area of previous treatment documented the failure of treatment. The patient elected to undergo a salvage RALP. The operation time was 159 minutes. The patient was discharged from the hospital on postoperative day 1 with no complications. The catheter was removed on post-op day 10. The patient reserved sexual function and urinary continence. The PSA levels on 6 months’ follow-up are undetectable. Conclusions. Salvage RALP is an effective and safe treatment choice for recurrent prostate adenocarcinoma following failed HIFU treatment if operated by an experienced surgeon.

  1. The impact of marketing language on patient preference for robot-assisted surgery.

    Science.gov (United States)

    Dixon, Peter R; Grant, Robert C; Urbach, David R

    2015-02-01

    Robot-assisted surgery is gaining momentum as a new trend in minimally invasive surgery. With limited evidence supporting its use in place of the far less expensive conventional laparoscopic surgery, it has been suggested that marketing pressure is partly responsible for its widespread adoption. The impact of phrases that promote the novelty of robot-assisted surgery on patient decision making has not been investigated. We conducted a discrete choice experiment to elicit preference of partial colectomy technique for a hypothetical diagnosis of colon cancer. A convenience sample of 38 participants in an ambulatory general surgery clinic consented to participate. Each participant made 2 treatment decisions between robot-assisted surgery and conventional laparoscopic surgery, with robot-assisted surgery described as "innovative" and "state-of-the-art" in one of the decisions (marketing frame), and by a disclosure of the uncertainty of available evidence in the other (evidence-based frame). The magnitude of the framing effect was large with 12 of 38 subjects (31.6%, P = .005) selecting robot-assisted surgery in the marketing frame and not the evidence-based frame. This is the first study to our knowledge to demonstrate that words that highlight novelty have an important influence on patient preference for robot-assisted surgery and that use of more neutral language can mitigate this effect. © The Author(s) 2014.

  2. Robot-assisted urologic surgery in 2010 - Advancements and future outlook

    Directory of Open Access Journals (Sweden)

    Paurush Babbar

    2011-01-01

    Full Text Available Robotic surgery is a cutting edge and minimally invasive procedure, which has generated a great deal of excitement in the urologic community. While there has been much advancement in this emerging technology, it is safe to say that robotic urologic surgery holds tremendous potential for progress in the near future. Hence, it is paramount that urologists stay up-to-date regarding new developments in the realm of robotics with respect to novel applications, limitations and opportunities for incorporation into their practice. Robot-assisted surgery provides an enhanced 3D view, increased magnification of the surgical field, better manual dexterity, relatively bloodless field, elimination of surgeon′s tremor, reduction in a surgeon′s fatigue and mitigation of scattered light. All these factors translate into greater precision of surgical dissection, which is imperative in providing better intraoperative and postoperative outcomes. Pioneering work assessing the feasibility of robotic surgery in urology began in the early 2000′s with robot-assisted radical prostatectomy and has since expanded to procedures such as robot-assisted radical cystectomy, robot-assisted partial nephrectomy, robot-assisted nephroureterectomy and robot-assisted pyeloplasty. A MEDLINE search was used to identify recent articles (within the last two years and publications of specific importance, which highlighted the recent developments and future direction of robotics. This review will use the aforementioned urologic surgeries as vehicles to evaluate the current status and future role of robotics in the advancement of the field of urology.

  3. Effort, performance, and motivation: insights from robot-assisted training of human golf putting and rat grip strength.

    Science.gov (United States)

    Duarte, Jaime E; Gebrekristos, Berkenesh; Perez, Sergi; Rowe, Justin B; Sharp, Kelli; Reinkensmeyer, David J

    2013-06-01

    Robotic devices can modulate success rates and required effort levels during motor training, but it is unclear how this affects performance gains and motivation. Here we present results from training unimpaired humans in a virtual golf-putting task, and training spinal cord injured (SCI) rats in a grip strength task using robotically modulated success rates and effort levels. Robotic assistance in golf practice increased trainees feelings of competence, and, paradoxically, increased their sense effort, even though it had mixed effects on learning. Reducing effort during a grip strength training task led rats with SCI to practice the task more frequently. However, the more frequent practice of these rats did not cause them to exceed the strength gains achieved by rats that exercised less often at higher required effort levels. These results show that increasing success and decreasing effort with robots increases motivation, but has mixed effects on performance gains.

  4. A vision-based system for fast and accurate laser scanning in robot-assisted phonomicrosurgery.

    Science.gov (United States)

    Dagnino, Giulio; Mattos, Leonardo S; Caldwell, Darwin G

    2015-02-01

    Surgical quality in phonomicrosurgery can be improved by open-loop laser control (e.g., high-speed scanning capabilities) with a robust and accurate closed-loop visual servoing systems. A new vision-based system for laser scanning control during robot-assisted phonomicrosurgery was developed and tested. Laser scanning was accomplished with a dual control strategy, which adds a vision-based trajectory correction phase to a fast open-loop laser controller. The system is designed to eliminate open-loop aiming errors caused by system calibration limitations and by the unpredictable topology of real targets. Evaluation of the new system was performed using CO(2) laser cutting trials on artificial targets and ex-vivo tissue. This system produced accuracy values corresponding to pixel resolution even when smoke created by the laser-target interaction clutters the camera view. In realistic test scenarios, trajectory following RMS errors were reduced by almost 80 % with respect to open-loop system performances, reaching mean error values around 30 μ m and maximum observed errors in the order of 60 μ m. A new vision-based laser microsurgical control system was shown to be effective and promising with significant positive potential impact on the safety and quality of laser microsurgeries.

  5. Robot-assisted partial nephrectomy for hilar tumors: perioperative outcomes.

    Science.gov (United States)

    Eyraud, Rémi; Long, Jean-Alexandre; Snow-Lisy, Devon; Autorino, Riccardo; Hillyer, Shahab; Klink, Joseph; Rizkala, Emad; Stein, Robert J; Kaouk, Jihad H; Haber, Georges-Pascal

    2013-06-01

    To compare perioperative outcomes of robot-assisted partial nephrectomy (RAPN) for hilar vs nonhilar tumors. The study retrospectively reviewed 364 patients with available computed tomography scans undergoing RAPN. Demographic data and perioperative outcomes results were compared between the hilar (group 1, n = 70) and nonhilar tumors (group 2, n = 294). Multivariate analysis was used to identify predictors of warm ischemia time (WIT), estimated blood loss (EBL), major perioperative complications, and postoperative renal function. There were no differences with respect to demographic variables. Hilar tumors had higher RENAL (radius, exophytic/endophytic properties of the tumor, nearness of tumor deepest portion to the collecting system or sinus, anterior/posterior descriptor and the location relative to polar lines) scores (P hilar tumors were associated with greater operative time (210 vs 180 minutes, P hilar vs nonhilar patients on postoperative day 3 (70.12 vs 74.71 mL/min/1.73 m(2), P = .31) or at last follow-up (72.62 vs 75.78 mL/min/1.73 m(2), P = .40), respectively. Multivariate analysis found hilar location was independently associated with increased WIT without significant changes in EBL, major complications, or postoperative renal function. RAPN represents a safe and effective procedure for hilar tumors. Hilar location for patients undergoing RAPN in a high-volume institution seems not be associated with an increased risk of transfusions, major complications, or decline of early postoperative renal function. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Understanding Cognitive Performance During Robot-Assisted Surgery.

    Science.gov (United States)

    Guru, Khurshid A; Shafiei, Somayeh B; Khan, Atif; Hussein, Ahmed A; Sharif, Mohamed; Esfahani, Ehsan T

    2015-10-01

    To understand cognitive function of an expert surgeon in various surgical scenarios while performing robot-assisted surgery. In an Internal Review Board approved study, National Aeronautics and Space Administration-Task Load Index (NASA-TLX) questionnaire with surgical field notes were simultaneously completed. A wireless electroencephalography (EEG) headset was used to monitor brain activity during all procedures. Three key portions were evaluated: lysis of adhesions, extended lymph node dissection, and urethro-vesical anastomosis (UVA). Cognitive metrics extracted were distraction, mental workload, and mental state. In evaluating lysis of adhesions, mental state (EEG) was associated with better performance (NASA-TLX). Utilizing more mental resources resulted in better performance as self-reported. Outcomes of lysis were highly dependent on cognitive function and decision-making skills. In evaluating extended lymph node dissection, there was a negative correlation between distraction level (EEG) and mental demand, physical demand and effort (NASA-TLX). Similar to lysis of adhesion, utilizing more mental resources resulted in better performance (NASA-TLX). Lastly, with UVA, workload (EEG) negatively correlated with mental and temporal demand and was associated with better performance (NASA-TLX). The EEG recorded workload as seen here was a combination of both cognitive performance (finding solution) and motor workload (execution). Majority of workload was contributed by motor workload of an expert surgeon. During UVA, muscle memory and motor skills of expert are keys to completing the UVA. Cognitive analysis shows that expert surgeons utilized different mental resources based on their need. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Controlling patient participation during robot-assisted gait training

    Science.gov (United States)

    2011-01-01

    Background The overall goal of this paper was to investigate approaches to controlling active participation in stroke patients during robot-assisted gait therapy. Although active physical participation during gait rehabilitation after stroke was shown to improve therapy outcome, some patients can behave passively during rehabilitation, not maximally benefiting from the gait training. Up to now, there has not been an effective method for forcing patient activity to the desired level that would most benefit stroke patients with a broad variety of cognitive and biomechanical impairments. Methods Patient activity was quantified in two ways: by heart rate (HR), a physiological parameter that reflected physical effort during body weight supported treadmill training, and by a weighted sum of the interaction torques (WIT) between robot and patient, recorded from hip and knee joints of both legs. We recorded data in three experiments, each with five stroke patients, and controlled HR and WIT to a desired temporal profile. Depending on the patient's cognitive capabilities, two different approaches were taken: either by allowing voluntary patient effort via visual instructions or by forcing the patient to vary physical effort by adapting the treadmill speed. Results We successfully controlled patient activity quantified by WIT and by HR to a desired level. The setup was thereby individually adaptable to the specific cognitive and biomechanical needs of each patient. Conclusion Based on the three successful approaches to controlling patient participation, we propose a metric which enables clinicians to select the best strategy for each patient, according to the patient's physical and cognitive capabilities. Our framework will enable therapists to challenge the patient to more activity by automatically controlling the patient effort to a desired level. We expect that the increase in activity will lead to improved rehabilitation outcome. PMID:21429200

  8. Consumerism and its impact on robotic-assisted radical prostatectomy.

    Science.gov (United States)

    Alkhateeb, Sultan; Lawrentschuk, Nathan

    2011-12-01

    • Many experts consider that media coverage, marketing and/or direct-to-consumer advertising, particularly Internet-based forms, are fundamental to the widespread adoption of robotic-assisted prostatectomy (RARP). However, this has not been explored previously. • The primary objective of the present study was to delineate the role of media coverage and marketing of RARP on the Internet, whereas the secondary goal focused on website quality with respect to the presentation of prostatectomy. • Website content was evaluated for direct-to-consumer advertising after the retrieval of the first 50 websites using Google and Yahoo for each of the terms: 'robotic prostatectomy, laparoscopic prostatectomy (LP) and open radical prostatectomy (ORP)'. • A linear regression analysis was performed for the annual number of Internet news hits over the last decade for each procedure. Website quality assessment was performed using WHO Honesty on the Internet (HON) code principles. • Of the retrieved sites, the proportion containing direct-to-consumer advertising for RARP vs LP vs ORP using Google was 64% vs 14% vs 0%, respectively (P 0.05). • Media coverage and marketing of RARP on the Internet is more widespread compared to LP and ORP. • Disturbingly, the quality of websites using any technique for prostatectomy was of poor quality when using principles of honest information presenting and such findings need to be discussed with respect to obtaining informed consent from patients. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  9. Robot Assisted Surgical Ward Rounds: Virtually Always There

    Directory of Open Access Journals (Sweden)

    Stefanie M. Croghan

    2018-05-01

    Full Text Available Background:  While an explosion in technological sophistication has revolutionized surgery within the operating theatre, delivery of surgical ward-based care has seen little innovation.  Use of telepresence allowing off-site clinicians communicate with patients has been largely restricted to outpatient settings or use of complex, expensive, static devices.  We designed a prospective study to ascertain feasibility and face validity of a remotely controlled mobile audiovisual drone (LUCY to access inpatients.  This device is, uniquely, lightweight, freely mobile and emulates ‘human’ interaction by swiveling and adjusting height to patients’ eye-level.     Methods: Robot-assisted ward rounds(RASWR were conducted over 3 months. A remotely located consultant surgeon communicated with patients/bedside teams via encrypted audiovisual telepresence robot (DoubleRoboticstm, California USA.  Likert-scale satisfaction questionnaires, incorporating free-text sections for mixed-methods data collection, were disseminated to patient and staff volunteers following RASWRs.  The same cohort completed a linked questionnaire following conventional (gold-standard rounds, acting as control group. Data were paired, and non-parametric analysis performed.     Results: RASWRs are feasible (>90% completed without technical difficulty. The RASWR(n=52 observations demonstrated face validity with strong correlations (r>0.7; Spearman, p-value <0.05 between robotic and conventional ward rounds among patients and staff on core themes, including dignity/confidentiality/communication/satisfaction with management plan. Patients (96.08%, n=25 agreed RASWR were a satisfactory alternative when consultant physical presence was not possible. There was acceptance of nursing/NCHD cohort (100% (n=11 willing to regularly partake in RASWR.    Conclusion: RASWRs receive high levels of patient and staff acceptance, and offer a valid alternative to conventional ward rounds

  10. Robot-Assisted Free Flap in Head and Neck Reconstruction

    Directory of Open Access Journals (Sweden)

    Han Gyeol Song

    2013-07-01

    Full Text Available BackgroundRobots have allowed head and neck surgeons to extirpate oropharyngeal tumors safely without the need for lip-split incision or mandibulotomy. Using robots in oropharyngeal reconstruction is new but essential for oropharyngeal defects that result from robotic tumor excision. We report our experience with robotic free-flap reconstruction of head and neck defects to exemplify the necessity for robotic reconstruction.MethodsWe investigated head and neck cancer patients who underwent ablation surgery and free-flap reconstruction by robot. Between July 1, 2011 and March 31, 2012, 5 cases were performed and patient demographics, location of tumor, pathologic stage, reconstruction methods, flap size, recipient vessel, necessary pedicle length, and operation time were investigated.ResultsAmong five free-flap reconstructions, four were radial forearm free flaps and one was an anterolateral thigh free-flap. Four flaps used the superior thyroid artery and one flap used a facial artery as the recipient vessel. The average pedicle length was 8.8 cm. Flap insetting and microanastomosis were achieved using a specially manufactured robotic instrument. The total operation time was 1,041.0 minutes (range, 814 to 1,132 minutes, and complications including flap necrosis, hematoma, and wound dehiscence did not occur.ConclusionsThis study demonstrates the clinically applicable use of robots in oropharyngeal reconstruction, especially using a free flap. A robot can assist the operator in insetting the flap at a deep portion of the oropharynx without the need to perform a traditional mandibulotomy. Robot-assisted reconstruction may substitute for existing surgical methods and is accepted as the most up-to-date method.

  11. Robot Assisted Surgical Ward Rounds: Virtually Always There.

    Science.gov (United States)

    Croghan, Stefanie M; Carroll, Paul; Reade, Sarah; Gillis, Amy E; Ridgway, Paul F

    2018-05-02

     While an explosion in technological sophistication has revolutionized surgery within the operating theatre, delivery of surgical ward-based care has seen little innovation.  Use of telepresence allowing off-site clinicians communicate with patients has been largely restricted to outpatient settings or use of complex, expensive, static devices.  We designed a prospective study to ascertain feasibility and face validity of a remotely controlled mobile audiovisual drone (LUCY) to access inpatients.  This device is, uniquely, lightweight, freely mobile and emulates 'human' interaction by swiveling and adjusting height to patients' eye-level.   METHODS: Robot-assisted ward rounds(RASWR) were conducted over 3 months. A remotely located consultant surgeon communicated with patients/bedside teams via encrypted audiovisual telepresence robot (DoubleRoboticstm, California USA).  Likert-scale satisfaction questionnaires, incorporating free-text sections for mixed-methods data collection, were disseminated to patient and staff volunteers following RASWRs.  The same cohort completed a linked questionnaire following conventional (gold-standard) rounds, acting as control group. Data were paired, and non-parametric analysis performed.  RESULTS: RASWRs are feasible (>90% completed without technical difficulty). The RASWR(n=52 observations) demonstrated face validity with strong correlations (r>0.7; Spearman, p-value <0.05) between robotic and conventional ward rounds among patients and staff on core themes, including dignity/confidentiality/communication/satisfaction with management plan. Patients (96.08%, n=25) agreed RASWR were a satisfactory alternative when consultant physical presence was not possible. There was acceptance of nursing/NCHD cohort (100% (n=11) willing to regularly partake in RASWR).  CONCLUSION: RASWRs receive high levels of patient and staff acceptance, and offer a valid alternative to conventional ward rounds when a consultant cannot be

  12. Robotic-assisted laparoscopic surgery: recent advances in urology.

    Science.gov (United States)

    Autorino, Riccardo; Zargar, Homayoun; Kaouk, Jihad H

    2014-10-01

    The aim of the present review is to summarize recent developments in the field of urologic robotic surgery. A nonsystematic literature review was performed to retrieve publications related to robotic surgery in urology and evidence-based critical analysis was conducted by focusing on the literature of the past 5 years. The use of the da Vinci Surgical System, a robotic surgical system, has been implemented for the entire spectrum of extirpative and reconstructive laparoscopic kidney procedures. The robotic approach can be applied for a range of adrenal indications as well as for ureteral diseases, including benign and malignant conditions affecting the proximal, mid, and distal ureter. Current evidence suggests that robotic prostatectomy is associated with less blood loss compared with the open surgery. Besides prostate cancer, robotics has been used for simple prostatectomy in patients with symptomatic benign prostatic hyperplasia. Recent studies suggest that minimally invasive radical cystectomy provides encouraging oncologic outcomes mirroring those reported for open surgery. In recent years, the evolution of robotic surgery has enabled urologic surgeons to perform urinary diversions intracorporeally. Robotic vasectomy reversal and several other robotic andrological applications are being explored. In summary, robotic-assisted surgery is an emerging and safe technology for most urologic operations. The acceptance of robotic prostatectomy during the past decade has paved the way for urologists to explore the entire spectrum of extirpative and reconstructive urologic procedures. Cost remains a significant issue that could be solved by wider dissemination of the technology. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  13. Pattern of improvement in upper limb pointing task kinematics after a 3-month training program with robotic assistance in stroke.

    Science.gov (United States)

    Pila, Ophélie; Duret, Christophe; Laborne, François-Xavier; Gracies, Jean-Michel; Bayle, Nicolas; Hutin, Emilie

    2017-10-13

    When exploring changes in upper limb kinematics and motor impairment associated with motor recovery in subacute post stroke during intensive therapies involving robot-assisted training, it is not known whether trained joints improve before non-trained joints and whether target reaching capacity improves before movement accuracy. Twenty-two subacute stroke patients (mean delay post-stroke at program onset 63 ± 29 days, M2) underwent 50 ± 17 (mean ± SD) 45-min sessions of robot-assisted (InMotion™) shoulder/elbow training over 3 months, in addition to conventional occupational therapy. Monthly evaluations (M2 to M5) included Fugl-Meyer Assessment (FM), with subscores per joint, and four robot-based kinematic measures: mean target distance covered, mean velocity, direction accuracy (inverse of root mean square error from straight line) and movement smoothness (inverse of mean number of zero-crossings in the velocity profile). We assessed delays to reach statistically significant improvement for each outcome measure. At M5, all clinical and kinematic parameters had markedly improved: Fugl-Meyer, +65% (median); distance covered, +87%; mean velocity, +101%; accuracy, +134%; and smoothness, +96%. Delays to reach statistical significance were M3 for the shoulder/elbow Fugl-Meyer subscore (+43%), M4 for the hand (+80%) and M5 for the wrist (+133%) subscores. For kinematic parameters, delays to significant improvements were M3 for distance (+68%), velocity (+65%) and smoothness (+50%), and M5 for accuracy (+134%). An intensive rehabilitation program combining robot-assisted shoulder/elbow training and conventional occupational therapy was associated with improvement in shoulder and elbow movements first, which suggests focal behavior-related brain plasticity. Findings also suggested that recovery of movement quantity related parameters (range of motion, velocity and smoothness) might precede that of movement quality (accuracy). EudraCT 2016-005121-36 . Date of

  14. CLINICAL EFFICACY OF THE ROBOT-ASSISTED LAPAROSCOPIC MYOMECTOMY (A REVIEW OF THE LITERATURE

    Directory of Open Access Journals (Sweden)

    V. A. Gudebskaya

    2016-01-01

    Full Text Available Rationale: One of the most complicated and unresolved problems in clinical medicine is the choice of an optimal method for organ-preservation treatment of uterine fibroids in women of childbearing age. Aim: To assess clinical efficacy of robot-assisted laparoscopic myomectomy. Materials and methods: The search was performed in PubMed, Embase, Trip, Cochrane, DocMe databases by keywords: “fibroids”, “robot”, “da Vinci”, “robotic myomectomy”, “robot-assisted myomectomy”. Results: We found 25 publications on robot-assisted laparoscopic myomectomy, including 6  papers on its reproductive outcomes (levels of evidence II–IV. Duration of robot-assisted surgery ranged from 132 to 261 minutes, intraoperative blood loss was in the range from 50 to 387 mL, postoperative hospital stay ranged from 1 to  3.9  days. There was a  lower percentage of intra- and postoperative complications after the robot-assisted interventions, compared to abdominal or classic laparoscopic access, as well as a lower percentage of conversion laparotomies compared to laparoscopy. Pregnancy rates after robotic myomectomy ranged from 16.7 to 69%. Only one case of uterine rupture after robot-assisted laparoscopic myomectomy has been described in the literature. Conclusion: Due to high cost of the method, the number of conducted studies is insufficient to evaluate the role of robotic technologies in the organ-preservation approach to uterine fibroids. Nevertheless, they suggest that robot-assisted laparoscopic myomectomy is justified in women of childbearing age who are planning pregnancy, with big centripetally growing intramural nodes and deformation of the uterine cavity. This technique on its own is an independent method for fertility restoration and could be the first step before the use of assisted reproductive technology.

  15. Incorporating robotic-assisted surgery for endometrial cancer staging: Analysis of morbidity and costs.

    Science.gov (United States)

    Bogani, Giorgio; Multinu, Francesco; Dowdy, Sean C; Cliby, William A; Wilson, Timothy O; Gostout, Bobbie S; Weaver, Amy L; Borah, Bijan J; Killian, Jill M; Bijlani, Akash; Angioni, Stefano; Mariani, Andrea

    2016-05-01

    To evaluate how the introduction of robotic-assisted surgery affects treatment-related morbidity and cost of endometrial cancer (EC) staging. We retrospectively reviewed the records of consecutive patients with stage I-III EC undergoing surgical staging between 2007 and 2012 at our institution. Costs (from surgery to 30days after surgery) were set based on the Medicare cost-to-charge ratio for each year and inflated to 2014 values. Inverse probability weighting (IPW) was used to decrease the allocation bias when comparing outcomes between surgical groups. We focused our analysis on the 251 EC patients who had robotic-assisted surgery and the 384 who had open staging. During the study period, the use of robotic-assisted surgery increased and open staging decreased (P<0.001). Correcting group imbalances by using IPW methodology, we observed that patients undergoing robotic-assisted staging had a significantly lower postoperative complication rate, lower blood transfusion rate, longer median operating time, shorter median length of stay, and lower readmission rate than patients undergoing open staging (all P<0.001). Overall 30-day costs were similar between the 2 groups, with robotic-assisted surgery having significantly higher median operating room costs ($2820 difference; P<0.001) but lower median room and board costs ($2929 difference; P<0.001) than open surgery. Increasing experience with robotic-assisted staging was significantly associated with a decrease in median operating time (P=0.002) and length of stay (P=0.003). The implementation of robotic-assisted surgery for EC staging improves patient outcomes. It provides women the benefits of minimally invasive surgery without increasing costs and potentially improves patient turnover. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Robot-Assisted Training for People With Spinal Cord Injury: A Meta-Analysis.

    Science.gov (United States)

    Cheung, Eddy Y Y; Ng, Thomas K W; Yu, Kevin K K; Kwan, Rachel L C; Cheing, Gladys L Y

    2017-11-01

    To investigate the effects of robot-assisted training on the recovery of people with spinal cord injury (SCI). Randomized controlled trials (RCTs) or quasi-RCTs involving people with SCI that compared robot-assisted upper limbs or lower limbs training with a control of other treatment approach or no treatment. We included studies involving people with complete or incomplete SCIs. We searched MEDLINE, CINAHL, Cochrane Central Register of Controlled Trials (Cochrane Library), and Embase to August 2016. Bibliographies of relevant articles on the effect of body-weight-supported treadmill training on subjects with SCI were screened to avoid missing relevant articles from the search of databases. All kinds of objective assessments concerning physical ability, mobility, and/or functional ability were included. Assessments could be clinical tests (ie, 6-minute walk test, FIM) or laboratory tests (ie, gait analysis). Subjective outcome measures were excluded from this review. Eleven RCT studies involving 443 subjects were included in the study. Meta-analysis was performed on the included studies. Walking independence (3.73; 95% confidence interval [CI], -4.92 to -2.53; P<.00001; I 2 =38%) and endurance (53.32m; 95% CI, -73.15 to -33.48; P<.00001; I 2 =0%) were found to have better improvement in robot-assisted training groups. Lower limb robot-assisted training was also found to be as effective as other types of body-weight-supported training. There is a lack of upper limb robot-assisted training studies; therefore, performing a meta-analysis was not possible. Robot-assisted training is an adjunct therapy for physical and functional recovery for patients with SCI. Future high-quality studies are warranted to investigate the effects of robot-assisted training on functional and cardiopulmonary recovery of patients with SCI. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  17. Does robotic assistance confer an economic benefit during laparoscopic radical nephrectomy?

    Science.gov (United States)

    Yang, David Y; Monn, M Francesca; Bahler, Clinton D; Sundaram, Chandru P

    2014-09-01

    While robotic assisted radical nephrectomy is safe with outcomes and complication rates comparable to those of the pure laparoscopic approach, there is little evidence of an economic or clinical benefit. From the 2009 to 2011 Nationwide Inpatient Sample database we identified patients 18 years old or older who underwent radical nephrectomy for primary renal malignancy. Robotic assisted and laparoscopic techniques were noted. Patients treated with the open technique and those with evidence of metastatic disease were excluded from analysis. Descriptive statistics were performed using the chi-square and Mann-Whitney tests, and the Student t-test. Multiple linear regression was done to examine factors associated with increased hospital costs and charges. We identified 24,312 radical nephrectomy cases for study inclusion, of which 7,787 (32%) were performed robotically. There was no demographic difference between robotic assisted and pure laparoscopic radical nephrectomy cases. Median total charges were $47,036 vs $38,068 for robotic assisted vs laparoscopic surgery (p robotic assisted surgery were $15,149 compared to $11,735 for laparoscopic surgery (p robotic assistance conferred an estimated $4,565 and $11,267 increase in hospital costs and charges, respectively, when adjusted for adapted Charlson comorbidity index score, perioperative complications and length of stay (p Robotic assisted radical nephrectomy results in increased medical expense without improving patient morbidity. Assuming surgeon proficiency with pure laparoscopy, robotic technology should be reserved primarily for complex surgeries requiring reconstruction. Traditional laparoscopic techniques should continue to be used for routine radical nephrectomy. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. Walking with robot assistance: the influence of body weight support on the trunk and pelvis kinematics.

    Science.gov (United States)

    Swinnen, Eva; Baeyens, Jean-Pierre; Knaepen, Kristel; Michielsen, Marc; Hens, Gerrit; Clijsen, Ron; Goossens, Maggie; Buyl, Ronald; Meeusen, Romain; Kerckhofs, Eric

    2015-05-01

    The goal was to assess in healthy participants the three-dimensional kinematics of the pelvis and the trunk during robot-assisted treadmill walking (RATW) at 0%, 30% and 50% body weight support (BWS), compared with treadmill walking (TW). 18 healthy participants walked (2 kmph) on a treadmill with and without robot assistance (Lokomat; 60% guidance force; 0%, 30% and 50% BWS). After an acclimatisation period (four minutes), trunk and pelvis kinematics were registered in each condition (Polhemus Liberty [240 Hz]). The results were analysed using a repeated measures analysis of variance with Bonferroni correction, with the level of suspension as within-subject factor. During RATW with BWS, there were significantly (1) smaller antero-posterior and lateral translations of the trunk and the pelvis; (2) smaller antero-posterior flexion and axial rotation of the trunk; (3) larger lateral flexion of the trunk; and (4) larger antero-posterior tilting of the pelvis compared with TW. There are significant differences in trunk and pelvis kinematics in healthy persons during TW with and without robot assistance. These data are relevant in gait rehabilitation, relating to normal balance regulation. Additional research is recommended to further assess the influence of robot assistance on human gait. The trunk and pelvis moves in a different way during walking with robot assistance. The data suggest that the change in movement is due to the robot device and the harness of the suspension system more than due to the level of suspension itself.

  19. Da Vinci robot-assisted system for thymectomy: experience of 55 patients in China.

    Science.gov (United States)

    Jun, Yi; Hao, Li; Demin, Li; Guohua, Dong; Hua, Jing; Yi, Shen

    2014-09-01

    Da Vinci robot-assisted thymectomy has been used in the past several years in China, however, practical experience in performing this approach in China remains limited. Thus, the study aimed to evaluate the experience of da Vinci robot-assisted thymectomy in China. From June 2010 to December 2012, 55 patients with diseases of the thymus underwent thymectomy using the da Vinci surgical HD robotic system. The clinical data of the da Vinci robot-assisted thymectomies were compared with the data of video-assisted thoracoscopic thymectomies in the same period. All da Vinci robot operations were successful. This is a retrospective analysis which demonstrated that compared with video-assisted thoracoscopic thymectomy in the same period, the clinical outcomes of da Vinci robot-assisted thymectomy were not significantly different. The da Vinci robot-assisted thymectomy is a safe, minimally invasive, and convenient operation, and shows promise for general thoracic surgery in China. Copyright © 2014 John Wiley & Sons, Ltd.

  20. Robot-assisted pancreatic surgery: a systematic review of the literature

    Science.gov (United States)

    Strijker, Marin; van Santvoort, Hjalmar C; Besselink, Marc G; van Hillegersberg, Richard; Borel Rinkes, Inne HM; Vriens, Menno R; Molenaar, I Quintus

    2013-01-01

    Background To potentially improve outcomes in pancreatic resection, robot-assisted pancreatic surgery has been introduced. This technique has possible advantages over laparoscopic surgery, such as its affordance of three-dimensional vision and increased freedom of movement of instruments. A systematic review was performed to assess the safety and feasibility of robot-assisted pancreatic surgery. Methods The literature published up to 30 September 2011 was systematically reviewed, with no restrictions on publication date. Studies reporting on over five patients were included. Animal studies, studies not reporting morbidity and mortality, review articles and conference abstracts were excluded. Data were extracted and weighted means were calculated. Results A total of 499 studies were screened, after which eight cohort studies reporting on a total of 251 patients undergoing robot-assisted pancreatic surgery were retained for analysis. Weighted mean operation time was 404 ± 102 min (510 ± 107 min for pancreatoduodenectomy only). The rate of conversion was 11.0% (16.4% for pancreatoduodenectomy only). Overall morbidity was 30.7% (n = 77), most frequently involving pancreatic fistulae (n = 46). Mortality was 1.6%. Negative surgical margins were obtained in 92.9% of patients. The rate of spleen preservation in distal pancreatectomy was 87.1%. Conclusions Robot-assisted pancreatic surgery seems to be safe and feasible in selected patients and, in left-sided resections, may increase the rate of spleen preservation. Randomized studies should compare the respective outcomes of robot-assisted, laparoscopic and open pancreatic surgery. PMID:23216773

  1. Unilateral versus bilateral robot-assisted rehabilitation on arm-trunk control and functions post stroke: a randomized controlled trial.

    Science.gov (United States)

    Wu, Ching-Yi; Yang, Chieh-Ling; Chen, Ming-de; Lin, Keh-Chung; Wu, Li-Ling

    2013-04-12

    Although the effects of robot-assisted arm training after stroke are promising, the relative effects of unilateral (URT) vs. bilateral (BRT) robot-assisted arm training remain uncertain. This study compared the effects of URT vs. BRT on upper extremity (UE) control, trunk compensation, and function in patients with chronic stroke. This was a single-blinded, randomized controlled trial. The intervention was implemented at 4 hospitals. Fifty-three patients with stroke were randomly assigned to URT, BRT, or control treatment (CT). Each group received UE training for 90 to 105 min/day, 5 days/week, for 4 weeks. The kinematic variables for arm motor control and trunk compensation included normalized movement time, normalized movement units, and the arm-trunk contribution slope in unilateral and bilateral tasks. Motor function and daily function were measured by the Wolf Motor Function Test (WMFT), Motor Activity Log (MAL), and ABILHAND Questionnaire. The BRT and CT groups elicited significantly larger slope values (i.e., less trunk compensation) at the start of bilateral reaching than the URT group. URT led to significantly better effects on WMFT-Time than BRT. Differences in arm control kinematics and performance on the MAL and ABILHAND among the 3 groups were not significant. BRT and URT resulted in differential improvements in specific UE/trunk performance in patients with stroke. BRT elicited larger benefits than URT on reducing compensatory trunk movements at the beginning of reaching. In contrast, URT produced better improvements in UE temporal efficiency. These relative effects on movement kinematics, however, did not translate into differential benefits in daily functions. ClinicalTrials.gov: NCT00917605.

  2. A novel computerized surgeon-machine interface for robot-assisted laser phonomicrosurgery.

    Science.gov (United States)

    Mattos, Leonardo S; Deshpande, Nikhil; Barresi, Giacinto; Guastini, Luca; Peretti, Giorgio

    2014-08-01

    To introduce a novel computerized surgical system for improved usability, intuitiveness, accuracy, and controllability in robot-assisted laser phonomicrosurgery. Pilot technology assessment. The novel system was developed involving a newly designed motorized laser micromanipulator, a touch-screen display, and a graphics stylus. The system allows the control of a CO2 laser through interaction between the stylus and the live video of the surgical area. This empowers the stylus with the ability to have actual effect on the surgical site. Surgical enhancements afforded by this system were established through a pilot technology assessment using randomized trials comparing its performance with a state-of-the-art laser microsurgery system. Resident surgeons and medical students were chosen as subjects in performing sets of trajectory-following exercises. Image processing-based techniques were used for an objective performance assessment. A System Usability Scale-based questionnaire was used for the qualitative assessment. The computerized interface demonstrated superiority in usability, accuracy, and controllability over the state-of-the-art system. Significant ease of use and learning experienced by the subjects were demonstrated by the usability score assigned to the two compared interfaces: computerized interface = 83.96% versus state-of-the-art = 68.02%. The objective analysis showed a significant enhancement in accuracy and controllability: computerized interface = 90.02% versus state-of-the-art = 75.59%. The novel system significantly enhances the accuracy, usability, and controllability in laser phonomicrosurgery. The design provides an opportunity to improve the ergonomics and safety of current surgical setups. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  3. Transversus abdominis plane (TAP) block after robot-assisted laparoscopic hysterectomy

    DEFF Research Database (Denmark)

    Torup, H; Bøgeskov, M; Hansen, E G

    2015-01-01

    BACKGROUND: Transversus abdominis plane (TAP) block is widely used as a part of pain management after various abdominal surgeries. We evaluated the effect of TAP block as an add-on to the routine analgesic regimen in patients undergoing robot-assisted laparoscopic hysterectomy. METHODS......: In a prospective blinded study, 70 patients scheduled for elective robot-assisted laparoscopic hysterectomy were randomised to receive either TAP block (ropivacaine 0.5%, 20 ml on each side) or sham block (isotonic saline 0.9%, 20 ml on each side). All patients had patient-controlled analgesia (PCA) with morphine...... and Nonsteroidal anti-inflammatory drugs (NSAID) treatment, had no effect on morphine consumption, VAS pain scores, or frequency of nausea and vomiting after robot-assisted laparoscopic hysterectomy compared with paracetamol and NSAID alone....

  4. Impact of metabolic syndrome on early recovery of continence after robot-assisted radical prostatectomy.

    Science.gov (United States)

    Nishikawa, Masatomo; Watanabe, Hiromitsu; Kurahashi, Toshifumi

    2017-09-01

    To evaluate the impact of metabolic syndrome on the early recovery of urinary continence after robot-assisted radical prostatectomy. The present study included a total of 302 consecutive Japanese patients with clinically localized prostate cancer who underwent robot-assisted radical prostatectomy. In this study, postoperative urinary continence was defined as no leak or the use of a security pad. The continence status was assessed by interviews before and 1 and 3 months after robot-assisted radical prostatectomy. Metabolic syndrome was defined as follows: body mass index ≥25 kg/m 2 and two or more of the following: hypertension, diabetes mellitus and dyslipidemia. The effect of the presence of metabolic syndrome on the continence status of these patients was retrospectively examined. A total of 116 (38.4%) and 203 (67.2%) of the 302 patients were continent at 1 and 3 months after robot-assisted radical prostatectomy, respectively. A total of 31 (10.3%) patients were judged to have metabolic syndrome. Despite the operative time being longer in patients with metabolic syndrome, no significant differences were observed in the remaining preoperative, intraoperative or postoperative variables between patients with or without metabolic syndrome. On multivariate logistic regression analysis, metabolic syndrome and the duration of hospitalization were significantly correlated with the 1-month continence status. Similarly, metabolic syndrome and estimated blood loss during surgery were independent predictors of continence rates at 3 months after robot-assisted radical prostatectomy. These findings suggest that the presence of metabolic syndrome could have a significant impact on the early recovery of urinary continence after robot-assisted radical prostatectomy. © 2017 The Japanese Urological Association.

  5. Human-robot cooperative movement training: Learning a novel sensory motor transformation during walking with robotic assistance-as-needed

    Directory of Open Access Journals (Sweden)

    Benitez Raul

    2007-03-01

    -as-needed algorithm proposed here can limit error during the learning of a dynamic motor task. The algorithm encourages learning by decreasing its assistance as a function of the ongoing progression of movement error. This type of algorithm is well suited for helping people learn dynamic tasks for which large kinematic errors are dangerous or discouraging, and thus may prove useful for robot-assisted movement training of walking or reaching following neurologic injury.

  6. Human-robot cooperative movement training: learning a novel sensory motor transformation during walking with robotic assistance-as-needed.

    Science.gov (United States)

    Emken, Jeremy L; Benitez, Raul; Reinkensmeyer, David J

    2007-03-28

    dynamic motor task. The algorithm encourages learning by decreasing its assistance as a function of the ongoing progression of movement error. This type of algorithm is well suited for helping people learn dynamic tasks for which large kinematic errors are dangerous or discouraging, and thus may prove useful for robot-assisted movement training of walking or reaching following neurologic injury.

  7. Robot-Assisted Laparoscopic Management of Caliceal Diverticular Calculi

    Directory of Open Access Journals (Sweden)

    Anneleen Verbrugghe

    2017-07-01

    Full Text Available Standard treatment modalities of caliceal diverticular calculi range from extracorporal shockwave lithotripsy (SWL over retrograde intrarenal surgery (RIRS, percutaneous nephrolithotomy (PNL and laparoscopic stone removal. A 55-year-old woman presented with a history of pyelonephritis based on a caliceal diverticular calculus. Due to the narrow infundibulum and anterior location, a robot-assisted laparoscopic calicotomy with extraction of the calculi and fulguration of the diverticulum was performed, with no specific perioperative problems and good stone-free results. This article shows technical feasibility with minimal morbidity of robot-assisted laparoscopic stone removal and obliteration of a caliceal diverticulum.

  8. The First Korean Experience of Telemanipulative Robot-Assisted Laparoscopic Cholecystectomy Using the da Vinci System

    Science.gov (United States)

    Kang, Chang Moo; Chi, Hoon Sang; Hyeung, Woo Jin; Kim, Kyung Sik; Choi, Jin Sub; Kim, Byong Ro

    2007-01-01

    With the advancement of laparoscopic instruments and computer sciences, complex surgical procedures are expected to be safely performed by robot assisted telemanipulative laparoscopic surgery. The da Vinci system (Intuitive Surgical, Mountain View, CA, USA) became available at the many surgical fields. The wrist like movements of the instrument's tip, as well as 3-dimensional vision, could be expected to facilitate more complex laparoscopic procedure. Here, we present the first Korean experience of da Vinci robotic assisted laparoscopic cholecystectomy and discuss the introduction and perspectives of this robotic system. PMID:17594166

  9. Two years of experience with robot-assisted anti-reflux surgery

    DEFF Research Database (Denmark)

    Sanberg Jensen, Jonas; Kold Antonsen, Henning; Durup, Jesper

    2017-01-01

    Background and aims Robot-assisted anti-reflux surgery (RAAS) is an alternative to conventional laparoscopic anti-reflux surgery (CLAS). The purpose of this study was to evaluate initial Danish experiences with robot-assisted anti-reflux surgery compared to conventional laparoscopic anti-reflux...... significantly dependent on type of fundic wrap with reoperation of Nissen fundoplication being dysphagia and reoperation of Toupet being recurrent reflux (p = 0.008). There was no clearly determined learning curve. Conclusions RAAS was safe, feasible and with equal efficacy to CLAS. There were however...

  10. Posterior muscolofascial reconstruction incorporated into urethrovescical anastomosis during robot-assisted radical prostatectomy.

    Science.gov (United States)

    Ficarra, Vincenzo; Gan, Melanie; Borghesi, Marco; Zattoni, Fabio; Mottrie, Alexandre

    2012-12-01

    The rationale of posterior musculofascial plate reconstruction during radical prostatectomy is to shorten the time to reach urinary continence recovery and to reduce the risk of bleeding and anastomosis leakage. We describe our original technique incorporating the posterior muscolofascial reconstruction into urethrovesical anastomosis using robot-assisted radical prostatectomy (RARP). For this reconstructive step, we use a 30-cm V-Loc 90 3-0 barbed suture (V-20 tapered needle). Specifically, the free edge of the posterior layer of the Denonvilliers fascia is approximated to the posterior part of the sphincteric apparatus in a running fashion from left to right. The musculature of the urethral wall is incorporated in this first layer of the running suture. This suture is then continued back to the left in a second layer incorporating the anterior layer of the Denonvilliers fascia (or prostatovesical muscle), the bladder neck, and again the urethra, this time also with urethral mucosa. The urethrovesical anastomosis is completed using a second running barbed suture (15-cm V-Loc 90 3-0 barbed suture, V-20 tapered needle). No intraoperative complications were observed during this step of the procedure. Anastomotic leakages were observed only in 2% of cases. Only 12.5% showed urinary incontinence after catheter removal (1-2 pads). At mean follow-up of 9 months, the urinary continence recovery was 95%, and an anastomosis stricture necessitating an endoscopic incision developed in only three (1.5%) patients. Recent systematic reviews of the literature showed only a minimal advantage in favor of posterior musculofascial reconstruction in terms of urinary continence recovery within 1 month after radical prostatectomy. We support the use of this step of RARP because it is simple, reproducible, with a very limited increase in operative time, and with only a slight risk of potential harm to the patient. Moreover, it could improve hemostasis and provide greater support for a

  11. Robot-assisted arm assessments in spinal cord injured patients: a consideration of concept study.

    Directory of Open Access Journals (Sweden)

    Urs Keller

    Full Text Available Robotic assistance is increasingly used in neurological rehabilitation for enhanced training. Furthermore, therapy robots have the potential for accurate assessment of motor function in order to diagnose the patient status, to measure therapy progress or to feedback the movement performance to the patient and therapist in real time. We investigated whether a set of robot-based assessments that encompasses kinematic, kinetic and timing metrics is applicable, safe, reliable and comparable to clinical metrics for measurement of arm motor function. Twenty-four healthy subjects and five patients after spinal cord injury underwent robot-based assessments using the exoskeleton robot ARMin. Five different tasks were performed with aid of a visual display. Ten kinematic, kinetic and timing assessment parameters were extracted on joint- and end-effector level (active and passive range of motion, cubic reaching volume, movement time, distance-path ratio, precision, smoothness, reaction time, joint torques and joint stiffness. For cubic volume, joint torques and the range of motion for most joints, good inter- and intra-rater reliability were found whereas precision, movement time, distance-path ratio and smoothness showed weak to moderate reliability. A comparison with clinical scores revealed good correlations between robot-based joint torques and the Manual Muscle Test. Reaction time and distance-path ratio showed good correlation with the "Graded and Redefined Assessment of Strength, Sensibility and Prehension" (GRASSP and the Van Lieshout Test (VLT for movements towards a predefined position in the center of the frontal plane. In conclusion, the therapy robot ARMin provides a comprehensive set of assessments that are applicable and safe. The first results with spinal cord injured patients and healthy subjects suggest that the measurements are widely reliable and comparable to clinical scales for arm motor function. The methods applied and results can

  12. Neural manual vs. robotic assisted mobilization to improve motion and reduce pain hypersensitivity in hand osteoarthritis: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Villafañe, Jorge Hugo; Valdes, Kristin; Imperio, Grace; Borboni, Alberto; Cantero-Téllez, Raquel; Galeri, Silvia; Negrini, Stefano

    2017-05-01

    [Purpose] The aim of the present study is to detail the protocol for a randomised controlled trial (RCT) of neural manual vs. robotic assisted on pain in sensitivity as well as analyse the quantitative and qualitative movement of hand in subjects with hand osteoarthritis. [Subjects and Methods] Seventy-two patients, aged 50 to 90 years old of both genders, with a diagnosis of hand Osteoarthritis (OA), will be recruited. Two groups of 36 participants will receive an experimental intervention (neurodynamic mobilization intervention plus exercise) or a control intervention (robotic assisted passive mobilization plus exercise) for 12 sessions over 4 weeks. Assessment points will be at baseline, end of therapy, and 1 and 3 months after end of therapy. The outcomes of this intervention will be pain and determine the central pain processing mechanisms. [Result] Not applicable. [Conclusion] If there is a reduction in pain hypersensitivity in hand OA patients it can suggest that supraspinal pain-inhibitory areas, including the periaqueductal gray matter, can be stimulated by joint mobilization.

  13. Resistive Exercise for Arthritic Cartilage Health (REACH: A randomized double-blind, sham-exercise controlled trial

    Directory of Open Access Journals (Sweden)

    Smith Richard M

    2009-01-01

    Full Text Available Abstract Background This article provides the rationale and methodology, of the first randomised controlled trial to our knowledge designed to assess the efficacy of progressive resistance training on cartilage morphology in women with knee osteoarthritis. Development and progression of osteoarthritis is multifactorial, with obesity, quadriceps weakness, joint malalignment, and abnormal mechanical joint forces particularly relevant to this study. Progressive resistance training has been reported to improve pain and disability in osteoarthritic cohorts. However, the disease-modifying potential of progressive resistance training for the articular cartilage degeneration characteristic of osteoarthritis is unknown. Our aim was to investigate the effect of high intensity progressive resistance training on articular cartilage degeneration in women with knee osteoarthritis. Methods Our cohort consisted of women over 40 years of age with primary knee osteoarthritis, according to the American College of Rheumatology clinical criteria. Primary outcome was blinded measurement of cartilage morphology via magnetic resonance imaging scan of the tibiofemoral joint. Secondary outcomes included walking endurance, balance, muscle strength, endurance, power, and velocity, body composition, pain, disability, depressive symptoms, and quality of life. Participants were randomized into a supervised progressive resistance training or sham-exercise group. The progressive resistance training group trained muscles around the hip and knee at 80% of their peak strength and progressed 3% per session, 3 days per week for 6 months. The sham-exercise group completed all exercises except hip adduction, but without added resistance or progression. Outcomes were repeated at 3 and 6 months, except for the magnetic resonance imaging scan, which was only repeated at 6 months. Discussion Our results will provide an evaluation of the disease-modifying potential of progressive

  14. Robot-assisted rectopexy is a safe and feasible option for treatment of rectal prolapse

    DEFF Research Database (Denmark)

    Haahr Raunkjær, Camilla; Jakobsen, Henrik Loft; Gögenur, Ismail

    2014-01-01

    INTRODUCTION: Rectal prolapse is seen in up to one in 100 elderly women and results in symptoms such as incontinence, mucus secretion and constipation. The aim of this study was to present short- and longterm outcomes after robot-assisted rectopexy in patients with rectal prolapse. MATERIAL AND M...

  15. Decoding sensorimotor rhythms during robotic-assisted treadmill walking for brain computer interface (BCI) applications

    NARCIS (Netherlands)

    Garcia Cossio, E.; Severens, M.; Nienhuis, B.; Duysens, J.; Desain, P.; Keijsers, N.; Farquhar, J.

    2015-01-01

    Locomotor malfunction represents a major problem in some neurological disorders like stroke and spinal cord injury. Robot-assisted walking devices have been used during rehabilitation of patients with these ailments for regaining and improving walking ability. Previous studies showed the advantage

  16. End-point impedance measurements across dominant and nondominant hands and robotic assistance with directional damping.

    Science.gov (United States)

    Erden, Mustafa Suphi; Billard, Aude

    2015-06-01

    The goal of this paper is to perform end-point impedance measurements across dominant and nondominant hands while doing airbrush painting and to use the results for developing a robotic assistance scheme. We study airbrush painting because it resembles in many ways manual welding, a standard industrial task. The experiments are performed with the 7 degrees of freedom KUKA lightweight robot arm. The robot is controlled in admittance using a force sensor attached at the end-point, so as to act as a free-mass and be passively guided by the human. For impedance measurements, a set of nine subjects perform 12 repetitions of airbrush painting, drawing a straight-line on a cartoon horizontally placed on a table, while passively moving the airbrush mounted on the robot's end-point. We measure hand impedance during the painting task by generating sudden and brief external forces with the robot. The results show that on average the dominant hand displays larger impedance than the nondominant in the directions perpendicular to the painting line. We find the most significant difference in the damping values in these directions. Based on this observation, we develop a "directional damping" scheme for robotic assistance and conduct a pilot study with 12 subjects to contrast airbrush painting with and without robotic assistance. Results show significant improvement in precision with both dominant and nondominant hands when using robotic assistance.

  17. Validation of in-line surface characterization by light scattering in Robot Assisted Polishing

    DEFF Research Database (Denmark)

    Pilny, Lukas; Bissacco, Giuliano; De Chiffre, Leonardo

    2014-01-01

    The suitability of a commercial scattered light sensor for in-line characterization of fine surfaces in the roughness range Sa 1 – 30 nm generated by the Robot Assisted Polishing (RAP) was investigated and validated. A number of surfaces were generated and directly measured with the scattered light...

  18. Robot-assisted placement of depth electrodes along the long Axis of the amygdalohippocampal complex

    Directory of Open Access Journals (Sweden)

    Alvin Y. Chan

    2016-12-01

    Conclusions: We have developed the Robot-Assisted Lateral Transoccipital Approach (RALTA, which is an advantageous technique for placing bilateral amygdalohippocampal depth electrodes using robotic guidance. Benefits of this technique include fewer electrodes required per patient and ease of positioning compared with seated or prone positioning.

  19. Matching technologies of home automation, robotics, assistance, geriatric telecare and telemedicine

    NARCIS (Netherlands)

    Franchimon, F.; Brink, M.

    2009-01-01

    The aging society could have a greater societal impact than the current financial crisis. The percentage of older adults has increased while the size of the health care workforce has remained constant. Home automation, robotics, assistive technology, geriatric telecare and telemedicine can support

  20. Robotic Assistance by Impedance Compensation for Hand Movements While Manual Welding.

    Science.gov (United States)

    Erden, Mustafa Suphi; Billard, Aude

    2016-11-01

    In this paper, we present a robotic assistance scheme which allows for impedance compensation with stiffness, damping, and mass parameters for hand manipulation tasks and we apply it to manual welding. The impedance compensation does not assume a preprogrammed hand trajectory. Rather, the intention of the human for the hand movement is estimated in real time using a smooth Kalman filter. The movement is restricted by compensatory virtual impedance in the directions perpendicular to the estimated direction of movement. With airbrush painting experiments, we test three sets of values for the impedance parameters as inspired from impedance measurements with manual welding. We apply the best of the tested sets for assistance in manual welding and perform welding experiments with professional and novice welders. We contrast three conditions: 1) welding with the robot's assistance; 2) with the robot when the robot is passive; and 3) welding without the robot. We demonstrate the effectiveness of the assistance through quantitative measures of both task performance and perceived user's satisfaction. The performance of both the novice and professional welders improves significantly with robotic assistance compared to welding with a passive robot. The assessment of user satisfaction shows that all novice and most professional welders appreciate the robotic assistance as it suppresses the tremors in the directions perpendicular to the movement for welding.

  1. Systematic review and cumulative analysis of perioperative outcomes and complications after robot-assisted radical cystectomy

    DEFF Research Database (Denmark)

    Novara, Giacomo; Catto, James W F; Wilson, Timothy

    2015-01-01

    and complications of RARC in comparison with ORC and LRC. EVIDENCE ACQUISITION: Medline, Scopus, and Web of Science databases were searched using a free-text protocol including the terms robot-assisted radical cystectomy or da Vinci radical cystectomy or robot* radical cystectomy. RARC case series and studies...

  2. Human likeness: cognitive and affective factors affecting adoption of robot-assisted learning systems

    Science.gov (United States)

    Yoo, Hosun; Kwon, Ohbyung; Lee, Namyeon

    2016-07-01

    With advances in robot technology, interest in robotic e-learning systems has increased. In some laboratories, experiments are being conducted with humanoid robots as artificial tutors because of their likeness to humans, the rich possibilities of using this type of media, and the multimodal interaction capabilities of these robots. The robot-assisted learning system, a special type of e-learning system, aims to increase the learner's concentration, pleasure, and learning performance dramatically. However, very few empirical studies have examined the effect on learning performance of incorporating humanoid robot technology into e-learning systems or people's willingness to accept or adopt robot-assisted learning systems. In particular, human likeness, the essential characteristic of humanoid robots as compared with conventional e-learning systems, has not been discussed in a theoretical context. Hence, the purpose of this study is to propose a theoretical model to explain the process of adoption of robot-assisted learning systems. In the proposed model, human likeness is conceptualized as a combination of media richness, multimodal interaction capabilities, and para-social relationships; these factors are considered as possible determinants of the degree to which human cognition and affection are related to the adoption of robot-assisted learning systems.

  3. Robot-assisted pyeloplasty: review of the current literature, technique and outcome.

    Science.gov (United States)

    Singh, Iqbal; Hemal, Ashok K

    2010-04-01

    To review the global select data on the current technique, perioperative outcome and literature on the robot-assisted pyeloplasty (RAP). The published English literature (PubMed) was extensively searched using the key words; robot, robot-assisted pyeloplasty, laparoscopy, laparoscopic pyeloplasty and ureteropelvic junction obstruction. The selected studies were then reviewed, tracked and analyzed in order to determine the current role, outcome and status of robot-assisted laparoscopic pyeloplasty. The search yielded about 25 published series on RAP comprising about 740 cases with a mean operative time, estimated blood loss, crossing vessel prevalence, hospital stay,perioperative complication rate and follow up duration of 194 min, 50 mL, 47%, 2.3 days, 6% and 14.9 months respectively. The initial peri-operative results and intermediate follow up of cases of repair of the ureteropelvic junction obstruction with robot-assisted pyeloplasty appear to be favorable and comparable to that of open pyeloplasty, while long term outcome data is still awaited. The da Vinci surgical robotic system is a promising surgical armamentarium in the hands of the modern day urologist for the minimally invasive definitive surgical management of both primary and secondary ureteropelvic junction obstruction.

  4. Exploring the ethical landscape of robot-assisted Search and Rescue

    NARCIS (Netherlands)

    Harbers, M.; Greeff, J. de; Kruijff-Korbayová, I.; Neerincx, M.A.; Hindriks, K.V.

    2017-01-01

    As robots are increasingly used in Search and Rescue (SAR) missions, it becomes highly relevant to study how SAR robots can be developed and deployed in a responsible way. In contrast to some other robot application domains, e.g. military and healthcare, the ethics of robot-assisted SAR are

  5. Rapid prototyping framework for robot-assisted training of autistic children

    NARCIS (Netherlands)

    Kim, Mingyu; Barakova, E.I.; Lourens, T.

    2014-01-01

    Research in uptake and actual use of robots in socially assistive tasks is rapidly growing. However, practical applications lack behind due to the enormous effort to create meaningful behaviours. This paper describes a rapid prototyping framework for robot-assisted training of children with Autism

  6. Development of a multisensory arm for process monitoring in Robot Assisted Polishing

    DEFF Research Database (Denmark)

    Pilny, Lukas; Dalla Costa, Giuseppe; Bissacco, Giuliano

    2015-01-01

    A multisensory polishing arm with integrated three component force sensor, a miniature acoustic emission (AE) sensor and an accelerometer was developed for process monitoring in Robot Assisted Polishing (RAP) process. The arm design was optimized for integration of a force and an AE sensor. The f...

  7. Hybrid procedure for total laryngectomy with a flexible robot-assisted surgical system.

    Science.gov (United States)

    Schuler, Patrick J; Hoffmann, Thomas K; Veit, Johannes A; Rotter, Nicole; Friedrich, Daniel T; Greve, Jens; Scheithauer, Marc O

    2017-06-01

    Total laryngectomy is a standard procedure in head-and-neck surgery for the treatment of cancer patients. Recent clinical experiences have indicated a clinical benefit for patients undergoing transoral robot-assisted total laryngectomy (TORS-TL) with commercially available systems. Here, a new hybrid procedure for total laryngectomy is presented. TORS-TL was performed in human cadavers (n = 3) using a transoral-transcervical hybrid procedure. The transoral approach was performed with a robotic flexible robot-assisted surgical system (Flex®) and compatible flexible instruments. Transoral access and visualization of anatomical landmarks were studied in detail. Total laryngectomy is feasible with a combined transoral-transcervical approach using the flexible robot-assisted surgical system. Transoral visualization of all anatomical structures is sufficient. The flexible design of the robot is advantageous for transoral surgery of the laryngeal structures. Transoral robot assisted surgery has the potential to reduce morbidity, hospital time and fistula rates in a selected group of patients. Initial clinical studies and further development of supplemental tools are in progress. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  8. Authoring Robot-Assisted Instructional Materials for Improving Learning Performance and Motivation in EFL Classrooms

    Science.gov (United States)

    Hong, Zeng-Wei; Huang, Yueh-Min; Hsu, Marie; Shen, Wei-Wei

    2016-01-01

    Anthropomorphized robots are regarded as beneficial tools in education due to their capabilities of improving teaching effectiveness and learning motivation. Therefore, one major trend of research, known as Robot- Assisted Language Learning (RALL), is trying to develop robots to support teaching and learning English as a foreign language (EFL). As…

  9. Human capital gains associated with robotic assisted laparoscopic pyeloplasty in children compared to open pyeloplasty.

    Science.gov (United States)

    Behan, James W; Kim, Steve S; Dorey, Frederick; De Filippo, Roger E; Chang, Andy Y; Hardy, Brian E; Koh, Chester J

    2011-10-01

    Robotic assisted laparoscopic pyeloplasty is an emerging, minimally invasive alternative to open pyeloplasty in children for ureteropelvic junction obstruction. The procedure is associated with smaller incisions and shorter hospital stays. To our knowledge previous outcome analyses have not included human capital calculations, especially regarding loss of parental workdays. We compared perioperative factors in patients who underwent robotic assisted laparoscopic and open pyeloplasty at a single institution, especially in regard to human capital changes, in an institutional cost analysis. A total of 44 patients 2 years old or older from a single institution underwent robotic assisted (37) or open (7) pyeloplasty from 2008 to 2010. We retrospectively reviewed the charts to collect demographic and perioperative data. The human capital approach was used to calculate parental productivity losses. Patients who underwent robotic assisted laparoscopic pyeloplasty had a significantly shorter average hospital length of stay (1.6 vs 2.8 days, p human capital gains, eg decreased lost parental wages, and lower hospitalization expenses. Future comparative outcome analyses in children should include financial factors such as human capital loss, which can be especially important for families with young children. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  10. Learning curve for robotic-assisted surgery for rectal cancer: use of the cumulative sum method.

    Science.gov (United States)

    Yamaguchi, Tomohiro; Kinugasa, Yusuke; Shiomi, Akio; Sato, Sumito; Yamakawa, Yushi; Kagawa, Hiroyasu; Tomioka, Hiroyuki; Mori, Keita

    2015-07-01

    Few data are available to assess the learning curve for robotic-assisted surgery for rectal cancer. The aim of the present study was to evaluate the learning curve for robotic-assisted surgery for rectal cancer by a surgeon at a single institute. From December 2011 to August 2013, a total of 80 consecutive patients who underwent robotic-assisted surgery for rectal cancer performed by the same surgeon were included in this study. The learning curve was analyzed using the cumulative sum method. This method was used for all 80 cases, taking into account operative time. Operative procedures included anterior resections in 6 patients, low anterior resections in 46 patients, intersphincteric resections in 22 patients, and abdominoperineal resections in 6 patients. Lateral lymph node dissection was performed in 28 patients. Median operative time was 280 min (range 135-683 min), and median blood loss was 17 mL (range 0-690 mL). No postoperative complications of Clavien-Dindo classification Grade III or IV were encountered. We arranged operative times and calculated cumulative sum values, allowing differentiation of three phases: phase I, Cases 1-25; phase II, Cases 26-50; and phase III, Cases 51-80. Our data suggested three phases of the learning curve in robotic-assisted surgery for rectal cancer. The first 25 cases formed the learning phase.

  11. Robotic assisted surgery in pediatric gynecology: promising innovation in mini invasive surgical procedures.

    Science.gov (United States)

    Nakib, Ghassan; Calcaterra, Valeria; Scorletti, Federico; Romano, Piero; Goruppi, Ilaria; Mencherini, Simonetta; Avolio, Luigi; Pelizzo, Gloria

    2013-02-01

    Robotic assisted surgery is not yet widely applied in the pediatric field. We report our initial experience regarding the feasibility, safety, benefits, and limitations of robot-assisted surgery in pediatric gynecological patients. Descriptive, retrospective report of experience with pediatric gynecological patients over a period of 12 months. Department of Pediatric Surgery, IRCCS Policlinico San Matteo Foundation. Children and adolescents, with a surgical diagnosis of ovarian and/or tubal lesions. Robot assembly time and operative time, days of hospitalization, time to cessation of pain medication, complication rate, conversion rate to laparoscopic procedure and trocar insertion strategy. Six children and adolescents (2.4-15 yrs), weighing 12-55 kg, underwent robotic assisted surgery for adnexal pathologies: 2 for ovarian cystectomy, 2 for oophorectomy, 1 for right oophorectomy and left salpingo-oophorectomy for gonadal disgenesis, 1 for exploration for suspected pelvic malformation. Mean operative time was 117.5 ± 34.9 minutes. Conversion to laparatomy was not necessary in any of the cases. No intra- or postoperative complications occurred. Initial results indicate that robotic assisted surgery is safely applicable in the pediatric gynecological population, although it is still premature to conclude that it provides better clinical outcomes than traditional laparoscopic surgery. Randomized, prospective, comparative studies will help characterize the advantages and disadvantages of this new technology in pediatric patients. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  12. Exploring requirements and alternative pet robots for robot assisted therapy with older adults with dementia

    NARCIS (Netherlands)

    P Martinez-Martim; J. Albo-Canals; S. Anisuzzaman; Marcel Heerink; M. Valenti-Soler; J. Zondag; C. Smits

    2013-01-01

    Robot assisted therapy has been applied in care for older adults who suffer from dementia for over ten years. Strong effects like improved interac-tion and signs of a higher sense of wellbeing have been reported. Still it is un-clear which features are needed and which robotic pets would are

  13. Manufacture of functional surfaces through combined application of tool manufacturing processes and Robot Assisted Polishing

    DEFF Research Database (Denmark)

    Eriksen, Rasmus Solmer; Arentoft, Mogens; Grønbæk, J.

    2012-01-01

    The tool surface topography is often a key parameter in the tribological performance of modern metal forming tools. A new generation of multifunctional surfaces is achieved by combination of conventional tool manufacturing processes with a novel Robot Assisted Polishing process. This novel surface...

  14. Dysfunctional breathing and reaching one’s physiological limit as causes of exercise-induced dyspnoea

    Directory of Open Access Journals (Sweden)

    Julie Depiazzi

    2016-06-01

    This review provides an overview of the spectrum of conditions that can present as exercise-­induced breathlessness experienced by young subjects participating in sport and aims to promote understanding of the need for accurate assessment of an individual’s symptoms. We will highlight the high incidence of nonasthmatic causes, which simply require reassurance or simple interventions from respiratory physiotherapists or speech pathologists.

  15. Robotic-Assisted Versus Manual Prostatic Arterial Embolization for Benign Prostatic Hyperplasia: A Comparative Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bagla, Sandeep, E-mail: sandeep.bagla@gmail.com [Vascular Institute of Virginia, LLC (United States); Smirniotopoulos, John [New York Presbyterian Hospital/Weill Cornell Medical Center (United States); Orlando, Julie C.; Piechowiak, Rachel [Vascular Institute of Virginia, LLC (United States)

    2017-03-15

    PurposeProstatic artery embolization (PAE) is a safe and efficacious procedure for benign prostatic hyperplasia (BPH), though is technically challenging. We present our experience of technical and clinical outcomes of robotic and manual PAE in patients with BPH.Materials and MethodsIRB-approved retrospective study of 40 consecutive patients 49–81 years old with moderate or severe grade BPH from May 2014 to July 2015: 20 robotic-assisted PAE (group 1), 20 manual PAE (group 2). Robotic-assisted PAE was performed using the Magellan Robotic System. American Urological Association (AUA-SI) score, cost, technical and clinical success, radiation dose, fluoroscopy, and procedure time were reviewed. Statistical analysis was performed within and between each group using paired t test and one-way analysis of variance respectively, at 1 and 3 months.ResultsNo significant baseline differences in age and AUA-SI between groups. Technical success was 100% (group 1) and 95% (group 2). One unsuccessful subject from group 2 returned for a successful embolization using robotic assistance. Fluoroscopy and procedural times were similar between groups, with a non-significant lower patient radiation dose in group 1 (30,632.8 mGy/cm{sup 2} vs 35,890.9, p = 0.269). Disposable cost was significantly different between groups with the robotic-assisted PAE incurring a higher cost (group 1 $4530.2; group 2 $1588.5, p < 0.0001). Clinical improvement was significant in both arms at 3 months: group 1 mean change in AUA-SI of 8.3 (p = 0.006), group 2: 9.6 (p < 0.0001). No minor or major complications occurred.ConclusionsRobotic-assisted PAE offers technical success comparable to manual PAE, with similar clinical improvement with an increased cost.

  16. Robotic Assistance for Training Finger Movement Using a Hebbian Model: A Randomized Controlled Trial.

    Science.gov (United States)

    Rowe, Justin B; Chan, Vicky; Ingemanson, Morgan L; Cramer, Steven C; Wolbrecht, Eric T; Reinkensmeyer, David J

    2017-08-01

    Robots that physically assist movement are increasingly used in rehabilitation therapy after stroke, yet some studies suggest robotic assistance discourages effort and reduces motor learning. To determine the therapeutic effects of high and low levels of robotic assistance during finger training. We designed a protocol that varied the amount of robotic assistance while controlling the number, amplitude, and exerted effort of training movements. Participants (n = 30) with a chronic stroke and moderate hemiparesis (average Box and Blocks Test 32 ± 18 and upper extremity Fugl-Meyer score 46 ± 12) actively moved their index and middle fingers to targets to play a musical game similar to GuitarHero 3 h/wk for 3 weeks. The participants were randomized to receive high assistance (causing 82% success at hitting targets) or low assistance (55% success). Participants performed ~8000 movements during 9 training sessions. Both groups improved significantly at the 1-month follow-up on functional and impairment-based motor outcomes, on depression scores, and on self-efficacy of hand function, with no difference between groups in the primary endpoint (change in Box and Blocks). High assistance boosted motivation, as well as secondary motor outcomes (Fugl-Meyer and Lateral Pinch Strength)-particularly for individuals with more severe finger motor deficits. Individuals with impaired finger proprioception at baseline benefited less from the training. Robot-assisted training can promote key psychological outcomes known to modulate motor learning and retention. Furthermore, the therapeutic effectiveness of robotic assistance appears to derive at least in part from proprioceptive stimulation, consistent with a Hebbian plasticity model.

  17. Robotic-assisted laparoscopic partial nephrectomy: initial experience in Brazil and a review of the literature

    Directory of Open Access Journals (Sweden)

    Carlo Camargo Passerotti

    2012-02-01

    Full Text Available CONTEXT AND PURPOSE: Partial nephrectomy has become the standard of care for renal tumors less than 4 cm in diameter. Controversy still exists, however, regarding the best surgical approach, especially when minimally invasive techniques are taken into account. Robotic-assisted laparoscopic partial nephrectomy (RALPN has emerged as a promising technique that helps surgeons achieve the standards of open partial nephrectomy care while offering a minimally invasive approach. The objective of the present study was to describe our initial experience with robotic-assisted laparoscopic partial nephrectomy and extensively review the pertinent literature. MATERIALS AND METHODS: Between August 2009 and February 2010, eight consecutive selected patients with contrast enhancing renal masses observed by CT were submitted to RALPN in a private institution. In addition, we collected information on the patients' demographics, preoperative tumor characteristics and detailed operative, postoperative and pathological data. In addition, a PubMed search was performed to provide an extensive review of the robotic-assisted laparoscopic partial nephrectomy literature. RESULTS: Seven patients had RALPN on the left or right sides with no intraoperative complications. One patient was electively converted to a robotic-assisted radical nephrectomy. The operative time ranged from 120 to 300 min, estimated blood loss (EBL ranged from 75 to 400 mL and, in five cases, the warm ischemia time (WIT ranged from 18 to 32 min. Two patients did not require any clamping. Overall, no transfusions were necessary, and there were no intraoperative complications or adverse postoperative clinical events. All margins were negative, and all patients were disease-free at the 6-month follow-up. CONCLUSIONS: Robotic-assisted laparoscopic partial nephrectomy is a feasible and safe approach to small renal cortical masses.Further prospective studies are needed to compare open partial nephrectomy with

  18. Robotic-Assisted Versus Manual Prostatic Arterial Embolization for Benign Prostatic Hyperplasia: A Comparative Analysis

    International Nuclear Information System (INIS)

    Bagla, Sandeep; Smirniotopoulos, John; Orlando, Julie C.; Piechowiak, Rachel

    2017-01-01

    PurposeProstatic artery embolization (PAE) is a safe and efficacious procedure for benign prostatic hyperplasia (BPH), though is technically challenging. We present our experience of technical and clinical outcomes of robotic and manual PAE in patients with BPH.Materials and MethodsIRB-approved retrospective study of 40 consecutive patients 49–81 years old with moderate or severe grade BPH from May 2014 to July 2015: 20 robotic-assisted PAE (group 1), 20 manual PAE (group 2). Robotic-assisted PAE was performed using the Magellan Robotic System. American Urological Association (AUA-SI) score, cost, technical and clinical success, radiation dose, fluoroscopy, and procedure time were reviewed. Statistical analysis was performed within and between each group using paired t test and one-way analysis of variance respectively, at 1 and 3 months.ResultsNo significant baseline differences in age and AUA-SI between groups. Technical success was 100% (group 1) and 95% (group 2). One unsuccessful subject from group 2 returned for a successful embolization using robotic assistance. Fluoroscopy and procedural times were similar between groups, with a non-significant lower patient radiation dose in group 1 (30,632.8 mGy/cm"2 vs 35,890.9, p = 0.269). Disposable cost was significantly different between groups with the robotic-assisted PAE incurring a higher cost (group 1 $4530.2; group 2 $1588.5, p < 0.0001). Clinical improvement was significant in both arms at 3 months: group 1 mean change in AUA-SI of 8.3 (p = 0.006), group 2: 9.6 (p < 0.0001). No minor or major complications occurred.ConclusionsRobotic-assisted PAE offers technical success comparable to manual PAE, with similar clinical improvement with an increased cost.

  19. Arm reduced robotic-assisted laparoscopic hysterectomy with transvaginal cuff closure.

    Science.gov (United States)

    Bodur, Serkan; Dede, Murat; Fidan, Ulas; Firatligil, Burcin F; Ulubay, Mustafa; Ozturk, Mustafa; Yenen, Mufit C

    2017-09-01

    The use of robotics for benign etiology in gynecology has not proven to be more beneficial when compared to traditional laparoscopy. The major concern regarding robotic hysterectomy stems from its high cost. To evaluate the clinical utility and effectiveness of one-arm reduced robotic-assisted laparoscopic hysterectomy as a cost-effective surgical option for total robotic hysterectomy. A sample population of 54 women who underwent robotic-assisted laparoscopic surgery for benign gynecologic indications was evaluated, and two groups were identified: (1) the two-armed robotic-assisted laparoscopic surgery group (n = 38 patients), and (2) the three-armed robotic-assisted laparoscopic surgery group (n = 16 patients). An increased cost was observed when three-armed robotic surgery was employed for benign gynecologic surgery (p < 0.001). The cost reduction observed in the study group was primarily derived from one robotic arm reduction and vaginal closure of the cuff. This cost reduction was achieved without an increase in complication rates or undesirable postoperative outcomes. An estimated profit between $399.5 and $421.5 was made for each patient depending on the suture material chosen for cuff closure. Two-armed surgery resulted in an 18.6% reduction in procedure-specific costs for robotic hysterectomy. Two-armed robotic-assisted laparoscopic hysterectomy appears to be a cost-effective solution for robotic gynecologic surgery. This surgical solution can be performed as effectively as classical three-armed robotic hysterectomies for benign indications without the risk of increased surgical-related morbidities. This approach has the potential to be a widely preferred surgical approach in medical communities where cost reduction is one of the primary determinants of surgery type.

  20. From Leonardo to da Vinci: the history of robot-assisted surgery in urology.

    Science.gov (United States)

    Yates, David R; Vaessen, Christophe; Roupret, Morgan

    2011-12-01

    What's known on the subject? and What does the study add? Numerous urological procedures can now be performed with robotic assistance. Though not definitely proven to be superior to conventional laparoscopy or traditional open surgery in the setting of a randomised trial, in experienced centres robot-assisted surgery allows for excellent surgical outcomes and is a valuable tool to augment modern surgical practice. Our review highlights the depth of history that underpins the robotic surgical platform we utilise today, whilst also detailing the current place of robot-assisted surgery in urology in 2011. The evolution of robots in general and as platforms to augment surgical practice is an intriguing story that spans cultures, continents and centuries. A timeline from Yan Shi (1023-957 bc), Archytas of Tarentum (400 bc), Aristotle (322 bc), Heron of Alexandria (10-70 ad), Leonardo da Vinci (1495), the Industrial Revolution (1790), 'telepresence' (1950) and to the da Vinci(®) Surgical System (1999), shows the incredible depth of history and development that underpins the modern surgical robot we use to treat our patients. Robot-assisted surgery is now well-established in Urology and although not currently regarded as a 'gold standard' approach for any urological procedure, it is being increasingly used for index operations of the prostate, kidney and bladder. We perceive that robotic evolution will continue infinitely, securing the place of robots in the history of Urological surgery. Herein, we detail the history of robots in general, in surgery and in Urology, highlighting the current place of robot-assisted surgery in radical prostatectomy, partial nephrectomy, pyeloplasty and radical cystectomy. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  1. Robot-assisted walking with the Lokomat: the influence of different levels of guidance force on thorax and pelvis kinematics.

    Science.gov (United States)

    Swinnen, Eva; Baeyens, Jean-Pierre; Knaepen, Kristel; Michielsen, Marc; Clijsen, Ron; Beckwée, David; Kerckhofs, Eric

    2015-03-01

    Little attention has been devoted to the thorax and pelvis movements during gait. The aim of this study is to compare differences in the thorax and pelvis kinematics during unassisted walking on a treadmill and during walking with robot assistance (Lokomat-system (Hocoma, Volketswil, Switzerland)). 18 healthy persons walked on a treadmill with and without the Lokomat system at 2kmph. Three different conditions of guidance force (30%, 60% and 100%) were used during robot-assisted treadmill walking (30% body weight support). The maximal movement amplitudes of the thorax and pelvis were measured (Polhemus Liberty™ (Polhemus, Colchester, Vermont, USA) (240/16)). A repeated measurement ANOVA was conducted. Robot-assisted treadmill walking with different levels of guidance force showed significantly smaller maximal movement amplitudes for thorax and pelvis, compared to treadmill walking. Only the antero-posterior tilting of the pelvis was significantly increased during robot-assisted treadmill walking compared to treadmill walking. No significant changes of kinematic parameters were found between the different levels of guidance force. With regard to the thorax and pelvis movements, robot-assisted treadmill walking is significantly different compared to treadmill walking. It can be concluded that when using robot assistance, the thorax is stimulated in a different way than during walking without robot assistance, influencing the balance training during gait. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Percutaneous cystostomy drainage for early removing urethral catheter in robotic-assisted laparoscopic radical prostatectomy: Improving on patients' discomfort

    Directory of Open Access Journals (Sweden)

    Che-Jui Yang

    2015-12-01

    Conclusion: The use of a percutaneous cystostomy device is feasible and safe for the early removal of urethral Foley catheter in robotic-assisted laparoscopic radical prostatectomy to decrease penile pain and patient discomfort.

  3. Lower Limb Voluntary Movement Improvement Following a Robot-Assisted Locomotor Training in Spinal Cord Injury

    Directory of Open Access Journals (Sweden)

    Mirbagheri Mehdi

    2011-12-01

    Full Text Available Individuals with spinal cord injury (SCI suffer from severe impairments in voluntary movements. Literature reports a reduction in major kinematic and kinetic parameters of lower limbs’ joints. A body weight support treadmill training with robotic assistance has been widely used to improve lower-extremity function and locomotion in persons with SCI. Our objective was to explore the effects of 4-weeks robot-assisted locomotor training on voluntary movement of the ankle musculature in patients with incomplete SCI. In particular, we aimed to characterize the therapeutic effects of Lokomat training on kinematic measures (range of motion, velocity, smoothness during a dorsiflexion movement. We hypothesized that training would improve these measures. Preliminary results show an improvement of kinematic parameters during ankle dorsiflexion voluntary movement after a 4-weeks training in the major part of our participants. Complementary investigations are in progress to confirm these results and understand underlying mechanisms associated with the recovery.

  4. 3D force control for robotic-assisted beating heart surgery based on viscoelastic tissue model.

    Science.gov (United States)

    Liu, Chao; Moreira, Pedro; Zemiti, Nabil; Poignet, Philippe

    2011-01-01

    Current cardiac surgery faces the challenging problem of heart beating motion even with the help of mechanical stabilizer which makes delicate operation on the heart surface difficult. Motion compensation methods for robotic-assisted beating heart surgery have been proposed recently in literature, but research on force control for such kind of surgery has hardly been reported. Moreover, the viscoelasticity property of the interaction between organ tissue and robotic instrument further complicates the force control design which is much easier in other applications by assuming the interaction model to be elastic (industry, stiff object manipulation, etc.). In this work, we present a three-dimensional force control method for robotic-assisted beating heart surgery taking into consideration of the viscoelastic interaction property. Performance studies based on our D2M2 robot and 3D heart beating motion information obtained through Da Vinci™ system are provided.

  5. Laparoscopic and robot-assisted laparoscopic digestive surgery: Present and future directions

    Science.gov (United States)

    Rodríguez-Sanjuán, Juan C; Gómez-Ruiz, Marcos; Trugeda-Carrera, Soledad; Manuel-Palazuelos, Carlos; López-Useros, Antonio; Gómez-Fleitas, Manuel

    2016-01-01

    Laparoscopic surgery is applied today worldwide to most digestive procedures. In some of them, such as cholecystectomy, Nissen’s fundoplication or obesity surgery, laparoscopy has become the standard in practice. In others, such as colon or gastric resection, the laparoscopic approach is frequently used and its usefulness is unquestionable. More complex procedures, such as esophageal, liver or pancreatic resections are, however, more infrequently performed, due to the high grade of skill necessary. As a result, there is less clinical evidence to support its implementation. In the recent years, robot-assisted laparoscopic surgery has been increasingly applied, again with little evidence for comparison with the conventional laparoscopic approach. This review will focus on the complex digestive procedures as well as those whose use in standard practice could be more controversial. Also novel robot-assisted procedures will be updated. PMID:26877605

  6. A laser unit for photodynamic therapy and robot-assisted microsurgery in dentistry

    Science.gov (United States)

    Chunikhin, A. A.; Bazikyan, E. A.; Pikhtin, N. A.

    2017-06-01

    Results are presented of photochemical experiments with an IR-laser unit for microsurgery and photodynamic therapy in dentistry. The efficiency of direct generation of singlet oxygen in model organic media in the continuous-wave and pulsed nanosecond modes is examined. The unit can serve both as an independent instrument and as a part of a complex for robot-assisted surgery and dentistry.

  7. How robotic-assisted surgery can decrease the risk of mucosal tear during Heller myotomy procedure?

    Science.gov (United States)

    Ballouhey, Quentin; Dib, Nabil; Binet, Aurélien; Carcauzon-Couvrat, Véronique; Clermidi, Pauline; Longis, Bernard; Lardy, Hubert; Languepin, Jane; Cros, Jérôme; Fourcade, Laurent

    2017-06-01

    We report the first description of robotic-assisted Heller myotomy in children. The purpose of this study was to improve the safety of Heller myotomy by demonstrating, in two adolescent patients, the contribution of the robot to the different steps of this procedure. Due to the robot's freedom of movement and three-dimensional vision, there was an improvement in the accuracy, a gain in the safety regarding different key-points, decreasing the risk of mucosal perforation associated with this procedure.

  8. Gait performance and foot pressure distribution during wearable robot-assisted gait in elderly adults.

    Science.gov (United States)

    Lee, Su-Hyun; Lee, Hwang-Jae; Chang, Won Hyuk; Choi, Byung-Ok; Lee, Jusuk; Kim, Jeonghun; Ryu, Gyu-Ha; Kim, Yun-Hee

    2017-11-28

    A robotic exoskeleton device is an intelligent system designed to improve gait performance and quality of life for the wearer. Robotic technology has developed rapidly in recent years, and several robot-assisted gait devices were developed to enhance gait function and activities of daily living in elderly adults and patients with gait disorders. In this study, we investigated the effects of the Gait-enhancing Mechatronic System (GEMS), a new wearable robotic hip-assist device developed by Samsung Electronics Co, Ltd., Korea, on gait performance and foot pressure distribution in elderly adults. Thirty elderly adults who had no neurological or musculoskeletal abnormalities affecting gait participated in this study. A three-dimensional (3D) motion capture system, surface electromyography and the F-Scan system were used to collect data on spatiotemporal gait parameters, muscle activity and foot pressure distribution under three conditions: free gait without robot assistance (FG), robot-assisted gait with zero torque (RAG-Z) and robot-assisted gait (RAG). We found increased gait speed, cadence, stride length and single support time in the RAG condition. Reduced rectus femoris and medial gastrocnemius muscle activity throughout the terminal stance phase and reduced effort of the medial gastrocnemius muscle throughout the pre-swing phase were also observed in the RAG condition. In addition, walking with the assistance of GEMS resulted in a significant increase in foot pressure distribution, specifically in maximum force and peak pressure of the total foot, medial masks, anterior masks and posterior masks. The results of the present study reveal that GEMS may present an alternative way of restoring age-related changes in gait such as gait instability with muscle weakness, reduced step force and lower foot pressure in elderly adults. In addition, GEMS improved gait performance by improving push-off power and walking speed and reducing muscle activity in the lower

  9. Robot-assisted laparoscopic pyeloplasty: minimum 1-year follow-up

    Science.gov (United States)

    Patel, Vipul; Thaly, Rahul; Shah, Ketul

    2007-02-01

    Objectives: To evaluate the feasibility and efficacy of robotic-assisted laparoscopic pyeloplasty. Laparoscopic pyeloplasty has been shown to have a success rate comparable to that of the open surgical approach. However, the steep learning curve has hindered its acceptance into mainstream urologic practice. The introduction of robotic assistance provides advantages that have the potential to facilitate precise dissection and intracorporeal suturing. Methods: A total of 50 patients underwent robotic-assisted laparoscopic dismembered pyeloplasty. A four-trocar technique was used. Most patients were discharged home on day 1, with stent removal at 3 weeks. Patency of the ureteropelvic junction was assessed in all patients with mercaptotriglycylglycine Lasix renograms at 1, 3, 6, 9, and 12 months, then every 6 months for 1 year, and then yearly. Results: Each patient underwent a successful procedure without open conversion or transfusion. The average estimated blood loss was 40 ml. The operative time averaged 122 minutes (range 60 to 330) overall. Crossing vessels were present in 30% of the patients and were preserved in all cases. The time for the anastomosis averaged 20 minutes (range 10 to 100). Intraoperatively, no complications occurred. Postoperatively, the average hospital stay was 1.1 days. The stents were removed at an average of 20 days (range 14 to 28) postoperatively. The average follow-up was 11.7 months; at the last follow-up visit, each patient was doing well. Of the 50 patients, 48 underwent one or more renograms, demonstrating stable renal function, improved drainage, and no evidence of recurrent obstruction. Conclusions: Robotic-assisted laparoscopic pyeloplasty is a feasible technique for ureteropelvic junction reconstruction. The procedure provides a minimally invasive alternative with good short-term results.

  10. Effects of realistic force feedback in a robotic assisted minimally invasive surgery system.

    Science.gov (United States)

    Moradi Dalvand, Mohsen; Shirinzadeh, Bijan; Nahavandi, Saeid; Smith, Julian

    2014-06-01

    Robotic assisted minimally invasive surgery systems not only have the advantages of traditional laparoscopic procedures but also restore the surgeon's hand-eye coordination and improve the surgeon's precision by filtering hand tremors. Unfortunately, these benefits have come at the expense of the surgeon's ability to feel. Several research efforts have already attempted to restore this feature and study the effects of force feedback in robotic systems. The proposed methods and studies have some shortcomings. The main focus of this research is to overcome some of these limitations and to study the effects of force feedback in palpation in a more realistic fashion. A parallel robot assisted minimally invasive surgery system (PRAMiSS) with force feedback capabilities was employed to study the effects of realistic force feedback in palpation of artificial tissue samples. PRAMiSS is capable of actually measuring the tip/tissue interaction forces directly from the surgery site. Four sets of experiments using only vision feedback, only force feedback, simultaneous force and vision feedback and direct manipulation were conducted to evaluate the role of sensory feedback from sideways tip/tissue interaction forces with a scale factor of 100% in characterising tissues of varying stiffness. Twenty human subjects were involved in the experiments for at least 1440 trials. Friedman and Wilcoxon signed-rank tests were employed to statistically analyse the experimental results. Providing realistic force feedback in robotic assisted surgery systems improves the quality of tissue characterization procedures. Force feedback capability also increases the certainty of characterizing soft tissues compared with direct palpation using the lateral sides of index fingers. The force feedback capability can improve the quality of palpation and characterization of soft tissues of varying stiffness by restoring sense of touch in robotic assisted minimally invasive surgery operations.

  11. Ankle voluntary movement enhancement following robotic-assisted locomotor training in spinal cord injury

    OpenAIRE

    Varoqui, Deborah; Niu, Xun; Mirbagheri, Mehdi M

    2014-01-01

    Background In incomplete spinal cord injury (iSCI), sensorimotor impairments result in severe limitations to ambulation. To improve walking capacity, physical therapies using robotic-assisted locomotor devices, such as the Lokomat, have been developed. Following locomotor training, an improvement in gait capabilities—characterized by increases in the over-ground walking speed and endurance—is generally observed in patients. To better understand the mechanisms underlying these improvements, we...

  12. Robotic-assisted transperitoneal radical prostatectomy in a patient with pelvic kidney

    International Nuclear Information System (INIS)

    Rabah, Danny M.; Alyami, Fahad A.

    2008-01-01

    Robots are increasingly utilized in urology, due to their favorable performance characteristics especially in prostatectomy and pyeloplasty. However, preoperative diagnosis of urogenital congenital anomalies and preoperative planning are important aspects to be considered. The presence of ectopic pelvic kidney is a challenge for the surgeon to perform robotic-assisted radical prostatectomy (RARP) without injury to the pelvic kidney (PC) or its blood supply. We report our experience of performing RARP in a patient with a PK. (author)

  13. Development of on the machine process monitoring and control strategy in Robot Assisted Polishing

    DEFF Research Database (Denmark)

    Pilny, Lukas; Bissacco, Giuliano

    2015-01-01

    Robot Assisted Polishing (RAP) can be used to polish rotational symmetric and free form components achieving surface roughness down to Sa 10 nm. With the aim to enable unmanned robust and cost efficient application of RAP, this paper presents the development of a monitoring and control strategy....... The multisensory approach was experimentally validated in polishing with bonded abrasives demonstrating its suitability for process control in RAP....

  14. Transoral robotic-assisted laryngeal cleft repair in the pediatric patient.

    Science.gov (United States)

    Leonardis, Rachel L; Duvvuri, Umamaheswar; Mehta, Deepak

    2014-09-01

    To assess the feasibility of performing robotic-assisted laryngeal cleft repair in the pediatric population. Retrospective chart review at a tertiary academic children's hospital. All patients underwent transoral robotic-assisted laryngeal cleft repair from March 2011 to June 2013. Demographics, robotic docking time, operative time, and postoperative course and swallowing function were collected and analyzed. Five children, three male and two female, underwent successful transoral robotic-assisted laryngeal cleft repair for closure of a type I laryngeal cleft. Mean age at time of surgery was 21.6 months (standard deviation 6.1 months; range, 15-29 months). From case 1 to case 5, robotic docking time (18-10 minutes), robotic operative time (102-36 minutes), and total operating room time (173-105 minutes) decreased. There were no complications with time until extubation (range, 2-3 days), length of intensive care unit stay (range, 3-4 days), and total hospital stay (range, 3-5 days) within acceptable range following laryngeal cleft repair. Modified barium swallow (two patients) or fiberoptic endoscopic evaluation of swallowing (three patients) was performed postoperatively, with all patients showing complete resolution of penetration and aspiration. In addition, all patients experienced subjective resolution of dysphagia and/or choking with feeds postoperatively. Transoral robotic-assisted laryngeal cleft repair may offer specific advantages over a traditional endoscopic approach. In our experience, the procedure was well tolerated and associated with definitive surgical cure in all patients. The scope of robotic technology continually expands and should be considered a feasible tool at an institution-based level. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  15. Recent trends in robot-assisted therapy environments to improve real-life functional performance after stroke

    Directory of Open Access Journals (Sweden)

    Johnson Michelle J

    2006-12-01

    Full Text Available Abstract Upper and lower limb robotic tools for neuro-rehabilitation are effective in reducing motor impairment but they are limited in their ability to improve real world function. There is a need to improve functional outcomes after robot-assisted therapy. Improvements in the effectiveness of these environments may be achieved by incorporating into their design and control strategies important elements key to inducing motor learning and cerebral plasticity such as mass-practice, feedback, task-engagement, and complex problem solving. This special issue presents nine articles. Novel strategies covered in this issue encourage more natural movements through the use of virtual reality and real objects and faster motor learning through the use of error feedback to guide acquisition of natural movements that are salient to real activities. In addition, several articles describe novel systems and techniques that use of custom and commercial games combined with new low-cost robot systems and a humanoid robot to embody the " supervisory presence" of the therapy as possible solutions to exercise compliance in under-supervised environments such as the home.

  16. Recent trends in robot-assisted therapy environments to improve real-life functional performance after stroke.

    Science.gov (United States)

    Johnson, Michelle J

    2006-12-18

    Upper and lower limb robotic tools for neuro-rehabilitation are effective in reducing motor impairment but they are limited in their ability to improve real world function. There is a need to improve functional outcomes after robot-assisted therapy. Improvements in the effectiveness of these environments may be achieved by incorporating into their design and control strategies important elements key to inducing motor learning and cerebral plasticity such as mass-practice, feedback, task-engagement, and complex problem solving. This special issue presents nine articles. Novel strategies covered in this issue encourage more natural movements through the use of virtual reality and real objects and faster motor learning through the use of error feedback to guide acquisition of natural movements that are salient to real activities. In addition, several articles describe novel systems and techniques that use of custom and commercial games combined with new low-cost robot systems and a humanoid robot to embody the " supervisory presence" of the therapy as possible solutions to exercise compliance in under-supervised environments such as the home.

  17. Human-Robot Interaction: Does Robotic Guidance Force Affect Gait-Related Brain Dynamics during Robot-Assisted Treadmill Walking?

    Directory of Open Access Journals (Sweden)

    Kristel Knaepen

    Full Text Available In order to determine optimal training parameters for robot-assisted treadmill walking, it is essential to understand how a robotic device interacts with its wearer, and thus, how parameter settings of the device affect locomotor control. The aim of this study was to assess the effect of different levels of guidance force during robot-assisted treadmill walking on cortical activity. Eighteen healthy subjects walked at 2 km.h-1 on a treadmill with and without assistance of the Lokomat robotic gait orthosis. Event-related spectral perturbations and changes in power spectral density were investigated during unassisted treadmill walking as well as during robot-assisted treadmill walking at 30%, 60% and 100% guidance force (with 0% body weight support. Clustering of independent components revealed three clusters of activity in the sensorimotor cortex during treadmill walking and robot-assisted treadmill walking in healthy subjects. These clusters demonstrated gait-related spectral modulations in the mu, beta and low gamma bands over the sensorimotor cortex related to specific phases of the gait cycle. Moreover, mu and beta rhythms were suppressed in the right primary sensory cortex during treadmill walking compared to robot-assisted treadmill walking with 100% guidance force, indicating significantly larger involvement of the sensorimotor area during treadmill walking compared to robot-assisted treadmill walking. Only marginal differences in the spectral power of the mu, beta and low gamma bands could be identified between robot-assisted treadmill walking with different levels of guidance force. From these results it can be concluded that a high level of guidance force (i.e., 100% guidance force and thus a less active participation during locomotion should be avoided during robot-assisted treadmill walking. This will optimize the involvement of the sensorimotor cortex which is known to be crucial for motor learning.

  18. Human-Robot Interaction: Does Robotic Guidance Force Affect Gait-Related Brain Dynamics during Robot-Assisted Treadmill Walking?

    Science.gov (United States)

    Knaepen, Kristel; Mierau, Andreas; Swinnen, Eva; Fernandez Tellez, Helio; Michielsen, Marc; Kerckhofs, Eric; Lefeber, Dirk; Meeusen, Romain

    2015-01-01

    In order to determine optimal training parameters for robot-assisted treadmill walking, it is essential to understand how a robotic device interacts with its wearer, and thus, how parameter settings of the device affect locomotor control. The aim of this study was to assess the effect of different levels of guidance force during robot-assisted treadmill walking on cortical activity. Eighteen healthy subjects walked at 2 km.h-1 on a treadmill with and without assistance of the Lokomat robotic gait orthosis. Event-related spectral perturbations and changes in power spectral density were investigated during unassisted treadmill walking as well as during robot-assisted treadmill walking at 30%, 60% and 100% guidance force (with 0% body weight support). Clustering of independent components revealed three clusters of activity in the sensorimotor cortex during treadmill walking and robot-assisted treadmill walking in healthy subjects. These clusters demonstrated gait-related spectral modulations in the mu, beta and low gamma bands over the sensorimotor cortex related to specific phases of the gait cycle. Moreover, mu and beta rhythms were suppressed in the right primary sensory cortex during treadmill walking compared to robot-assisted treadmill walking with 100% guidance force, indicating significantly larger involvement of the sensorimotor area during treadmill walking compared to robot-assisted treadmill walking. Only marginal differences in the spectral power of the mu, beta and low gamma bands could be identified between robot-assisted treadmill walking with different levels of guidance force. From these results it can be concluded that a high level of guidance force (i.e., 100% guidance force) and thus a less active participation during locomotion should be avoided during robot-assisted treadmill walking. This will optimize the involvement of the sensorimotor cortex which is known to be crucial for motor learning.

  19. Evolution of upper limb kinematics four years after subacute robot-assisted rehabilitation in stroke patients.

    Science.gov (United States)

    Pila, Ophélie; Duret, Christophe; Gracies, Jean-Michel; Francisco, Gerard E; Bayle, Nicolas; Hutin, Émilie

    2018-04-25

    To assess functional status and robot-based kinematic measures four years after subacute robot-assisted rehabilitation in hemiparesis. Twenty-two patients with stroke-induced hemiparesis underwent a ≥3-month upper limb combined program of robot-assisted and occupational therapy from two months post-stroke, and received community-based therapy after discharge. Four years later, 19 (86%) participated in this follow-up study. Assessments 2, 5 and 54 months post-stroke included Fugl-Meyer (FM), Modified Frenchay Scale (MFS, at Month 54) and robot-based kinematic measures of targeting tasks in three directions, north, paretic and non-paretic: distance covered, velocity, accuracy (root mean square (RMS) error from straight line) and smoothness (number of velocity peaks; upward changes in accuracy and smoothness represent worsening). Analysis was stratified by FM score at two months: ≥17 (Group 1) or Kinematic changes (three directions pooled) were: distance -1[-17;2]% (ns); velocity, -8[-32;28]% (ns); accuracy, +6[-13;98]% (ns); smoothness, +44[-6;126]% (p robot-assisted upper limb training during subacute post-stroke phase, movement kinematics deteriorated despite community-based therapy, especially in more severely impaired patients. EudraCT 2016-005121-36. Registration: 2016-12-20. Date of enrolment of the first participant to the trial: 2009-11-24.

  20. Body weight support during robot-assisted walking: influence on the trunk and pelvis kinematics.

    Science.gov (United States)

    Swinnen, Eva; Baeyens, Jean-Pierre; Hens, Gerrit; Knaepen, Kristel; Beckwée, David; Michielsen, Marc; Clijsen, Ron; Kerckhofs, Eric

    2015-01-01

    Efficacy studies concerning robot assisted gait rehabilitation showed limited clinical benefits. A changed kinematic pattern might be responsible for this. Little is known about the kinematics of the trunk and pelvis during robot assisted treadmill walking (RATW). The aim of this study was to assess the trunk and pelvis kinematics of healthy subjects during RATW, with different amounts of body weight support (BWS) compared to regular treadmill walking (TW). Eighteen healthy participants walked on a treadmill, while kinematics were registered by an electromagnetic tracking device. Hereafter, the kinematics of pelvis and trunk were registered during RATW (guidance force 30%) with 0%, 30% and 50% BWS. Compared to TW, RATW showed a decrease in the following trunk movements: axial rotation, anteroposterior flexion, lateral and anteroposterior translation. Besides, a decrease in lateral tilting and all translation of the pelvis was found when comparing RATW with TW. Furthermore, the anteroposterior tilting of the pelvis increased during RATW. In general, there was a decrease in trunk and pelvis movement amplitude during RATW compared with regular TW. Though, it is not known if these changes are responsible for the limited efficacy of robot assisted gait rehabilitation. Further research is indicated.

  1. Robotic-assisted transoral removal of a bilateral floor of mouth ranulas

    Directory of Open Access Journals (Sweden)

    Stromeyer Frederick W

    2011-07-01

    Full Text Available Abstract Objective To describe the management of bilateral oral ranulas with the use of the da Vinci Si Surgical System and discuss advantages and disadvantages over traditional transoral resection. Study Design Case Report and Review of Literature. Results A 47 year old woman presented to our service with an obvious right floor of mouth swelling. Clinical evaluation and computerized tomography scan confirmed a large floor of mouth ranula on the right and an incidental asymptomatic early ranula of the left sublingual gland. After obtaining an informed consent, the patient underwent a right transoral robotic-assisted transoral excision of the ranula and sublingual gland with identification and dissection of the submandibular duct and lingual nerve. The patient had an excellent outcome with no evidence of lingual nerve paresis and a return to oral intake on the first postoperative day. Subsequently, the patient underwent an elective transoral robotic-assisted excision of the incidental ranula on the left sublingual gland. Conclusion We describe the first robotic-assisted excision of bilateral oral ranulas in current literature. The use of the da Vinci system provides excellent visualization, magnification, and dexterity for transoral surgical management of ranulas with preservation of the lingual nerve and Wharton's duct with good functional outcomes. However, the use of the robotic system for anterior floor of mouth surgery in terms of improved surgical outcomes as compared to traditional transoral surgery, long-term recurrence rates, and cost effectiveness needs further validation.

  2. Cost-effectiveness of open versus laparoscopic versus robotic-assisted laparoscopic cystectomy and urinary diversion.

    Science.gov (United States)

    Zehnder, Pascal; Gill, Inderbir S

    2011-09-01

    To provide insight into the recently published cost comparisons in the context of open, laparoscopic, and robotic-assisted laparoscopic radical cystectomy and to demonstrate the complexity of such economic analyses. Most economic evaluations are from a hospital perspective and summarize short-term perioperative therapeutic costs. However, the contributing factors (e.g. study design, included variables, robotic amortization plan, supply contract, surgical volume, surgeons' experience, etc.) vary substantially between the institutions. In addition, a real cost-effective analysis considering cost per quality-adjusted life-year gained is not feasible because of the lack of long-term oncologic and functional outcome data with the robotic procedure. On the basis of a modeled cost analysis using results from published series, robotic-assisted cystectomy was - with few exceptions - found to be more expensive when compared with the open approach. Immediate costs are affected most by operative time, followed by length of hospital stay, robotic supply, case volume, robotic cost, and transfusion rate. Any complication substantially impacts overall costs. Economic cost evaluations are complex analyses influenced by numerous factors that hardly allow an interinstitutional comparison. Robotic-assisted cystectomy is constantly refined with many institutions being somewhere on their learning curve. Transparent reports of oncologic and functional outcome data from centers of expertise applying standardized methods will help to properly analyze the real long-term benefits of robotic surgery and successor technologies and prevent us from becoming slaves of successful marketing strategies.

  3. Initial experience with the new da Vinci single-port robot-assisted platform.

    Science.gov (United States)

    Ballestero Diego, R; Zubillaga Guerrero, S; Truan Cacho, D; Carrion Ballardo, C; Velilla Diez, G; Calleja Hermosa, P; Gutiérrez Baños, J L

    2017-06-01

    To describe our experience in the first cases of urological surgeries performed with the da Vinci single-port robot-assisted platform. We performed 5 single-port robot-assisted surgeries (R-LESS) between May and October 2014. We performed 3 ureteral reimplant surgeries, one ureteropyeloplasty in an inverted kidney and 1 partial nephrectomy. The perioperative and postoperative results were collected, as well as a report of the complications according to the Clavien classification system. Of the 5 procedures, 4 were performed completely by LESS, while 1 procedure was reconverted to multiport robot-assisted surgery. There were no intraoperative complications. We observed perioperative complications in 4 patients, all of which were grade 1 or 2. The mean surgical time was 262minutes (range, 230-300). In our initial experience with the da Vinci device, R-LESS surgery was feasible and safe. There are still a number of limitations in its use, which require new and improved R-LESS platforms. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Slow Versus Fast Robot-Assisted Locomotor Training After Severe Stroke: A Randomized Controlled Trial.

    Science.gov (United States)

    Rodrigues, Thais Amanda; Goroso, Daniel Gustavo; Westgate, Philip M; Carrico, Cheryl; Batistella, Linamara R; Sawaki, Lumy

    2017-10-01

    Robot-assisted locomotor training on a bodyweight-supported treadmill is a rehabilitation intervention that compels repetitive practice of gait movements. Standard treadmill speed may elicit rhythmic movements generated primarily by spinal circuits. Slower-than-standard treadmill speed may elicit discrete movements, which are more complex than rhythmic movements and involve cortical areas. Compare effects of fast (i.e., rhythmic) versus slow (i.e., discrete) robot-assisted locomotor training on a bodyweight-supported treadmill in subjects with chronic, severe gait deficit after stroke. Subjects (N = 18) were randomized to receive 30 sessions (5 d/wk) of either fast or slow robot-assisted locomotor training on a bodyweight-supported treadmill in an inpatient setting. Functional ambulation category, time up and go, 6-min walk test, 10-m walk test, Berg Balance Scale, and Fugl-Meyer Assessment were administered at baseline and postintervention. The slow group had statistically significant improvement on functional ambulation category (first quartile-third quartile, P = 0.004), 6-min walk test (95% confidence interval [CI] = 1.8 to 49.0, P = 0.040), Berg Balance Scale (95% CI = 7.4 to 14.8, P locomotor training on a bodyweight-supported treadmill after severe stroke, slow training targeting discrete movement may yield greater benefit than fast training.

  5. Novel posterior reconstruction technique during robot-assisted laparoscopic prostatectomy: description and comparative outcomes.

    Science.gov (United States)

    Jeong, Chang Wook; Oh, Jong Jin; Jeong, Seong Jin; Hong, Sung Kyu; Byun, Seok-Soo; Choe, Gheeyoung; Lee, Sang Eun

    2012-07-01

    The aim of the present study was to assess the impact of a novel posterior reconstruction technique during robot-assisted laparoscopic prostatectomy on continence recovery. A total of 116 consecutive patients who received the novel posterior reconstruction (case group) were retrospectively compared with a cohort of 126 patients who did not receive posterior reconstruction (control group). The primary end-point was the duration of continence recovery (no pad use) after robot-assisted laparoscopic prostatectomy. The posterior reconstruction was obtained by opposing the median dorsal fibrous raphe to the posterior counterpart of the detrusor apron, rather than the Denonvilliers' fascia. The case group showed higher continence rates at all points of evaluation, which were 2 weeks (30.1% vs 19.8%), 1 month (58.4% vs 45.7%), 3 months (82.7% vs 70.5%) and 6 months postoperatively (95.3% vs 86.4%) (P = 0.007). Application of the novel posterior reconstruction technique, age and length of membranous urethra were significant variables for the complete recovery of continence on multivariable analysis. This study shows that the application of this novel PR technique significantly improves the recovery of continence in patients undergoing robot-assisted laparoscopic prostatectomy. © 2012 The Japanese Urological Association.

  6. The role of visual and direct force feedback in robotics-assisted mitral valve annuloplasty.

    Science.gov (United States)

    Currie, Maria E; Talasaz, Ali; Rayman, Reiza; Chu, Michael W A; Kiaii, Bob; Peters, Terry; Trejos, Ana Luisa; Patel, Rajni

    2017-09-01

    The objective of this work was to determine the effect of both direct force feedback and visual force feedback on the amount of force applied to mitral valve tissue during ex vivo robotics-assisted mitral valve annuloplasty. A force feedback-enabled master-slave surgical system was developed to provide both visual and direct force feedback during robotics-assisted cardiac surgery. This system measured the amount of force applied by novice and expert surgeons to cardiac tissue during ex vivo mitral valve annuloplasty repair. The addition of visual (2.16 ± 1.67), direct (1.62 ± 0.86), or both visual and direct force feedback (2.15 ± 1.08) resulted in lower mean maximum force applied to mitral valve tissue while suturing compared with no force feedback (3.34 ± 1.93 N; P forces on cardiac tissue during robotics-assisted mitral valve annuloplasty suturing, force feedback may be required. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Robot-assisted intracerebral hemorrhage evacuation: an experimental evaluation

    Science.gov (United States)

    Burgner, Jessica; Swaney, Philip J.; Lathrop, Ray A.; Weaver, Kyle D.; Webster, Robert J.

    2013-03-01

    We present a novel robotic approach for the rapid, minimally invasive treatment of Intracerebral Hemorrhage (ICH), in which a hematoma or blood clot arises in the brain parenchyma. We present a custom image-guided robot system that delivers a steerable cannula into the lesion and aspirates it from the inside. The steerable cannula consists of an initial straight tube delivered in a manner similar to image-guided biopsy (and which uses a commercial image guidance system), followed by the sequential deployment of multiple individual precurved elastic tubes. Rather than deploying the tubes simultaneously, as has been done in nearly all prior studies, we deploy the tubes one at a time, using a compilation of their individual workspaces to reach desired points inside the lesion. This represents a new paradigm in active cannula research, defining a novel procedure-planning problem. A design that solves this problem can potentially save many lives by enabling brain decompression both more rapidly and less invasively than is possible through the traditional open surgery approach. Experimental results include a comparison of the simulated and actual workspaces of the prototype robot, and an accuracy evaluation of the system.

  8. Effect of Regional Hospital Competition and Hospital Financial Status on the Use of Robotic-Assisted Surgery.

    Science.gov (United States)

    Wright, Jason D; Tergas, Ana I; Hou, June Y; Burke, William M; Chen, Ling; Hu, Jim C; Neugut, Alfred I; Ananth, Cande V; Hershman, Dawn L

    2016-07-01

    Despite the lack of efficacy data, robotic-assisted surgery has diffused rapidly into practice. Marketing to physicians, hospitals, and patients has been widespread, but how this marketing has contributed to the diffusion of the technology remains unknown. To examine the effect of regional hospital competition and hospital financial status on the use of robotic-assisted surgery for 5 commonly performed procedures. A cohort study of 221 637 patients who underwent radical prostatectomy, total nephrectomy, partial nephrectomy, hysterectomy, or oophorectomy at 1370 hospitals in the United States from January 1, 2010, to December 31, 2011, was conducted. The association between hospital competition, hospital financial status, and performance of robotic-assisted surgery was examined. The association between hospital competition was measured with the Herfindahl-Hirschman Index (HHI), hospital financial status was estimated as operating margin, and performance of robotic-assisted surgery was examined using multivariate mixed-effects regression models. We identified 221 637 patients who underwent one of the procedures of interest. The cohort included 30 345 patients who underwent radical prostatectomy; 20 802, total nephrectomy; 8060, partial nephrectomy; 134 985, hysterectomy; and 27 445, oophorectomy. Robotic-assisted operations were performed for 20 500 (67.6%) radical prostatectomies, 1405 (6.8%) total nephrectomies, 2759 (34.2%) partial nephrectomies, 14 047 (10.4%) hysterectomies, and 1782 (6.5%) oophorectomies. Use of robotic-assisted surgery increased for each procedure from January 2010 through December 2011. For all 5 operations, increased market competition (as measured by the HHI) was associated with increased use of robotic-assisted surgery. For prostatectomy, the risk ratios (95% CIs) for undergoing a robotic-assisted procedure were 2.20 (1.50-3.24) at hospitals in moderately competitive markets and 2.64 (1.84-3.78) for highly competitive markets

  9. Robot-Assisted Middle Pancreatectomy for Elderly Patients: Our Initial Experience

    Science.gov (United States)

    Zhang, Tian; Wang, Xinjing; Huo, Zhen; Wen, Chenlei; Wu, Zhichong; Zhan, Qian; Jin, Jiabin; Cheng, Dongfeng; Chen, Hao; Deng, Xiaxing; Shen, Baiyong; Peng, Chenghong

    2015-01-01

    Background The aim of this study was to evaluate the indications, safety, feasibility, and short- and long-term outcomes for elderly patients who underwent robot-assisted middle pancreatectomies (MPs). Material/Methods Ten patients (≥60 years) underwent robot-assisted middle pancreatectomies from 2012 to 2015. The perioperative data, including tumor size, operating time, rate of postoperative pancreatic fistula (POPF), postoperative morbidity, and other parameters, were analyzed. We collected and analyzed the follow-up information. Results The mean age of patients was 64.30 years (range, 60–73 years). The average tumor size was 2.61 cm. The 10 cases were all benign or low-grade malignant lesions. The mean operating time was 175.00 min. The mean blood loss was 113.00 ml with no blood transfusion needed. Postoperative fistulas developed in 5 patients; there were 2 Grade A fistulas and 3 grade B fistulas. There were 3 patients who underwent postoperative complications, including 2 Grade 1 or 2 complications and 1 Grade 3 complication. No reoperation and postoperative mortality occurred. The mean hospital stay was 19.91 days. After a median follow-up of 23 months, new onset of diabetes mellitus developed in 1 patient and none suffered from deterioration of previously diagnosed diabetes or exocrine insufficiency, and no tumor recurrence happened. Conclusions Robot-assisted middle pancreatectomy was safe and feasible for elderly people. It had low risk of exocrine or endocrine dysfunction and benefited patients’ long-term outcomes. Incidence of POPF was relatively high but we could prevent it from resulting in bad outcomes by scientific perioperative care and systemic treatment. PMID:26395335

  10. Robot-assisted radical cystoprostatectomy: Analysis of the complications and oncological and functional aspects.

    Science.gov (United States)

    Kanashiro, A; Gaya, J M; Palou, J; Gausa, L; Villavicencio, H

    2017-05-01

    To review our experience in robot-assisted radical cystectomy, assessing the complications and oncological and functional results. From 2007 to 2014, we performed 67 robot-assisted radical cystectomies combined with lymphadenectomy in 61 cases. The operations were performed on 37 patients due to muscle-invasive tumours and on 30 due to high-risk nonmuscle-invasive tumours. Urinary diversion was conducted extracorporeally, using a Studer neobladder in 47 cases. The mean blood loss was 300mL. No case required conversion to open surgery. The median number of lymph nodes extracted was 16 (range 3-33). Pathology revealed 16 pT0, 15 pTis,-pT1-pTa and 44 muscle-invasive tumours, 8 pN+ and 1 with positive margins. The mean hospital stay was 9 days. With a median follow-up of 16 months, 9 (13%) patients were readmitted after the discharge, most for infections associated with the vesical catheter and other catheters. Forty patients (59.7%) presented complications (most were Clavien grade 1-2). There was recurrence during the follow-up in 4 cases (6%), and 4 (5.9%) patients died from cancer. Nineteen (28.3%) patients had complications after 30 days, most of which were urinary tract infections. Of the 47 patients with a neobladder, 45 (96%) had proper daytime continence and 42 (89%) had proper nighttime continence. Ninety percent and 64% of the patients with previously normal sexual function and reduced sexual function, respectively, were able to preserve sexual function with or without drug treatment. Robot-assisted radical cystectomy plus lymphadenectomy, with extracorporeal reconstruction of the urinary diversion, offers good oncological and functional results without increasing the number of complications. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Effect of Robot-Assisted Game Training on Upper Extremity Function in Stroke Patients

    Science.gov (United States)

    2017-01-01

    Objective To determine the effects of combining robot-assisted game training with conventional upper extremity rehabilitation training (RCT) on motor and daily functions in comparison with conventional upper extremity rehabilitation training (OCT) in stroke patients. Methods Subjects were eligible if they were able to perform the robot-assisted game training and were divided randomly into a RCT and an OCT group. The RCT group performed one daily session of 30 minutes of robot-assisted game training with a rehabilitation robot, plus one daily session of 30 minutes of conventional rehabilitation training, 5 days a week for 2 weeks. The OCT group performed two daily sessions of 30 minutes of conventional rehabilitation training. The effects of training were measured by a Manual Function Test (MFT), Manual Muscle Test (MMT), Korean version of the Modified Barthel Index (K-MBI) and a questionnaire about satisfaction with training. These measurements were taken before and after the 2-week training. Results Both groups contained 25 subjects. After training, both groups showed significant improvements in motor and daily functions measured by MFT, MMT, and K-MBI compared to the baseline. Both groups demonstrated similar training effects, except motor power of wrist flexion. Patients in the RCT group were more satisfied than those in the OCT group. Conclusion There were no significant differences in changes in most of the motor and daily functions between the two types of training. However, patients in the RCT group were more satisfied than those in the OCT group. Therefore, RCT could be a useful upper extremity rehabilitation training method. PMID:28971037

  12. Effect of Robot-Assisted Game Training on Upper Extremity Function in Stroke Patients.

    Science.gov (United States)

    Lee, Kyeong Woo; Kim, Sang Beom; Lee, Jong Hwa; Lee, Sook Joung; Kim, Jin Wan

    2017-08-01

    To determine the effects of combining robot-assisted game training with conventional upper extremity rehabilitation training (RCT) on motor and daily functions in comparison with conventional upper extremity rehabilitation training (OCT) in stroke patients. Subjects were eligible if they were able to perform the robot-assisted game training and were divided randomly into a RCT and an OCT group. The RCT group performed one daily session of 30 minutes of robot-assisted game training with a rehabilitation robot, plus one daily session of 30 minutes of conventional rehabilitation training, 5 days a week for 2 weeks. The OCT group performed two daily sessions of 30 minutes of conventional rehabilitation training. The effects of training were measured by a Manual Function Test (MFT), Manual Muscle Test (MMT), Korean version of the Modified Barthel Index (K-MBI) and a questionnaire about satisfaction with training. These measurements were taken before and after the 2-week training. Both groups contained 25 subjects. After training, both groups showed significant improvements in motor and daily functions measured by MFT, MMT, and K-MBI compared to the baseline. Both groups demonstrated similar training effects, except motor power of wrist flexion. Patients in the RCT group were more satisfied than those in the OCT group. There were no significant differences in changes in most of the motor and daily functions between the two types of training. However, patients in the RCT group were more satisfied than those in the OCT group. Therefore, RCT could be a useful upper extremity rehabilitation training method.

  13. Acoustic emission-based in-process monitoring of surface generation in robot-assisted polishing

    DEFF Research Database (Denmark)

    Pilny, Lukas; Bissacco, Giuliano; De Chiffre, Leonardo

    2016-01-01

    The applicability of acoustic emission (AE) measurements for in-process monitoring of surface generation in the robot-assisted polishing (RAP) was investigated. Surface roughness measurements require interruption of the process, proper surface cleaning and measurements that sometimes necessitate...... automatic detection of optimal process endpoint allow intelligent process control, creating fundamental elements in development of robust fully automated RAP process for its widespread industrial application....... removal of the part from the machine tool. In this study, stabilisation of surface roughness during polishing rotational symmetric surfaces by the RAP process was monitored by AE measurements. An AE sensor was placed on a polishing arm in direct contact with a bonded abrasive polishing tool...

  14. ACOG Technology Assessment in Obstetrics and Gynecology No. 6: Robot-assisted surgery.

    Science.gov (United States)

    2009-11-01

    The field of robotic surgery is developing rapidly, but experience with this technology is currently limited. In response to increasing interest in robotics technology, the Committee on Gynecologic Practice's Technology Assessment was developed to describe the robotic surgical system,potential advantages and disadvantages, gynecologic applications, and the current state of the evidence. Randomized trials comparing robot-assisted surgery with traditional laparoscopic, vaginal, or abdominal surgery are needed to evaluate long-term clinical outcomes and cost-effectiveness, as well as to identify the best applications of this technology.

  15. Complications and health-related quality of life after robot-assisted versus open radical cystectomy

    DEFF Research Database (Denmark)

    Lauridsen, Susanne Vahr; Tønnesen, Hanne; Jensen, Bente Thoft

    2017-01-01

    Background: Radical cystectomy is associated with high rates of perioperative morbidity. Robotic-assisted radical cystectomy (RARC) is widely used today despite limited evidence for clinical superiority. The aim of this review was to evaluate the effect of RARC compared to open radical cystectomy...... (ORC) on complications and secondary on length of stay, time back to work and health-related quality of life (HRQoL). Methods: The databases PubMed, The Cochrane Library, Embase and CINAHL were searched. A systematic review according to the PRISMA guidelines and cumulative analysis was conducted...

  16. The learning curve of robot-assisted laparoscopic aortofemoral bypass grafting for aortoiliac occlusive disease.

    Science.gov (United States)

    Novotný, Tomáš; Dvorák, Martin; Staffa, Robert

    2011-02-01

    Since the end of the 20th century, robot-assisted surgery has been finding its role among other minimally invasive methods. Vascular surgery seems to be another specialty in which the benefits of this technology can be expected. Our objective was to assess the learning curve of robot-assisted laparoscopic aortofemoral bypass grafting for aortoiliac occlusive disease in a group of 40 patients. Between May 2006 and January 2010, 40 patients (32 men, 8 women), who were a median age of 58 years (range, 48-75 years), underwent 40 robot-assisted laparoscopic aortofemoral reconstructions. Learning curve estimations were used for anastomosis, clamping, and operative time assessment. For conversion rate evaluation, the cumulative summation (CUSUM) technique was used. Statistical analysis comparing the first and second half of our group, and unilateral-to-bilateral reconstructions were performed. We created 21 aortofemoral and 19 aortobifemoral bypasses. The median proximal anastomosis time was 23 minutes (range, 18-50 minutes), median clamping time was 60 minutes (range, 40-95 minutes), and median operative time was 295 minutes (range, 180-475 minutes). The 30-day mortality rate was 0%, and no graft or wound infection or cardiopulmonary or hepatorenal complications were observed. During the median 18-month follow-up (range, 2-48 months), three early graft occlusions occurred (7%). After reoperations, the secondary patency of reconstructions was 100%. Data showed a typical short learning curve for robotic proximal anastomosis creation with anastomosis and clamping time reduction. The operative time learning curve was flat, confirming the procedure's complexity. There were two conversions to open surgery. CUSUM analysis confirmed that an acceptable conversion rate set at 5% was achieved. Comparing the first and second half of our group, all recorded times showed statistically significant improvements. Differences between unilateral and bilateral reconstructions were not

  17. Robotic-assisted laparoscopic hysterectomy versus conventional laparoscopic hysterectomy for benign gynaecological disease

    DEFF Research Database (Denmark)

    Sloth, Sigurd Beier; Rudnicki, Martin; Gimbel, Helga

    Background: In May 2015 the Danish Health and Medicines Authority is publishing a national clinical guideline on hysterectomy for benign gynaecological conditions. One of the key issues assessed in the guideline is the effectiveness of robotic-assisted laparoscopic hysterectomy (RALH) versus...... conventional laparoscopic hysterectomy (LH). Aims: The purpose was to evaluate available evidence on RALH versus LH and to advise surgeons and decision makers in the Danish healthcare system. Methods: A search specialist conducted a systematic literature search. Results were restricted to clinical guidelines...

  18. Measuring the Latency of an Augmented Reality System for Robot-Assisted Minimally Invasive Surgery

    DEFF Research Database (Denmark)

    Jørgensen, Martin Kibsgaard; Kraus, Martin

    2017-01-01

    visual communication in training for robot-assisted minimally invasive surgery with da Vinci surgical systems. To make sure that our augmented reality system provides the best possible user experience, we investigated the video latency of the da Vinci surgical system and how the components of our system...... affect the overall latency. To measure the photon-to-photon latency, we used a microcontroller to determine the time between the activation of a lightemitting diode in front of the endoscopic camera and the corresponding increase in intensity of the surgeon's display as measured by a phototransistor...

  19. Coherent anti-Stokes Raman scattering rigid endoscope toward robot-assisted surgery.

    Science.gov (United States)

    Hirose, K; Aoki, T; Furukawa, T; Fukushima, S; Niioka, H; Deguchi, S; Hashimoto, M

    2018-02-01

    Label-free visualization of nerves and nervous plexuses will improve the preservation of neurological functions in nerve-sparing robot-assisted surgery. We have developed a coherent anti-Stokes Raman scattering (CARS) rigid endoscope to distinguish nerves from other tissues during surgery. The developed endoscope, which has a tube with a diameter of 12 mm and a length of 270 mm, achieved 0.91% image distortion and 8.6% non-uniformity of CARS intensity in the whole field of view (650 μm diameter). We demonstrated CARS imaging of a rat sciatic nerve and visualization of the fine structure of nerve fibers.

  20. Individualized robot-assisted training for MS- and stroke patients in I-TRAVLE

    Directory of Open Access Journals (Sweden)

    Bastiaens Hanne

    2011-12-01

    Full Text Available Persons with central nervous deficits, such as MS and stroke patients, can benefit a lot from suitable training approaches that enhance their ability to perform activities in daily life. Personalized training, in accordance with the individual capabilities of the patient is a key issue in this context. We propose several techniques for individualization, including adaptive training games. Evaluations with patients and therapists reveal appreciation for the resulting Individualized, Technology-supported and RobotAssisted Virtual Learning Environments (I-TRAVLE system.

  1. Lumbosacral osteomyelitis after robot-assisted total laparoscopic hysterectomy and sacral colpopexy.

    Science.gov (United States)

    Muffly, Tyler M; Diwadkar, Gouri B; Paraiso, Marie Fidela R

    2010-12-01

    We report on the transabdominal resection of infected lumbosacral bone, synthetic mesh, and sinus tract following sacral colpopexy. A 45-year-old nulliparous patient who had undergone transvaginal mesh followed by robot-assisted sacral colpopexy presented with increasing back pain and foul-smelling vaginal drainage. An epidural abscess required surgical intervention, including diskectomy, sacral debridement, and mesh removal to drain the abscess and vaginal sinus tract. Recognized complications of open prolapse procedures also manifest following minimally invasive approaches. Osteomyelitis of the sacral promontory following sacral colpopexy may require gynecologic and neurosurgical management.

  2. Robotic-assisted laparoscopic excision of gossypiboma simulating bladder wall mass after 35 years of appendectomy

    Directory of Open Access Journals (Sweden)

    Emad Sabri Rajih

    2014-01-01

    Full Text Available Gossypiboma or textiloma are terms commonly used to describe a retained sponge in the body that is composed of sponge invested within a layer of foreign body reaction in the form of an abscess or an aseptic fibrotic reaction. These cases are rarely reported despite an incidence of 1:1,000-1,500 of abdominal or pelvic surgery. We report a patient who presented with an incidental supravesical mass discovered upon work up for frequency and suprapubic pain. He had appendectomy 35 years ago. The mass was excised by robotic-assisted laparoscopic technique. The pathologic evaluation came as gossypiboma.

  3. General surgery residents' perception of robot-assisted procedures during surgical training.

    Science.gov (United States)

    Farivar, Behzad S; Flannagan, Molly; Leitman, I Michael

    2015-01-01

    With the continued expansion of robotically assisted procedures, general surgery residents continue to receive more exposure to this new technology as part of their training. There are currently no guidelines or standardized training requirements for robot-assisted procedures during general surgical residency. The aim of this study was to assess the effect of this new technology on general surgery training from the residents' perspective. An anonymous, national, web-based survey was conducted on residents enrolled in general surgery training in 2013. The survey was sent to 240 Accreditation Council for Graduate Medical Education-approved general surgery training programs. Overall, 64% of the responding residents were men and had an average age of 29 years. Half of the responses were from postgraduate year 1 (PGY1) and PGY2 residents, and the remainder was from the PGY3 level and above. Overall, 50% of the responses were from university training programs, 32% from university-affiliated programs, and 18% from community-based programs. More than 96% of residents noted the availability of the surgical robot system at their training institution. Overall, 63% of residents indicated that they had participated in robotic surgical cases. Most responded that they had assisted in 10 or fewer robotic cases with the most frequent activities being assisting with robotic trocar placement and docking and undocking the robot. Only 18% reported experience with operating the robotic console. More senior residents (PGY3 and above) were involved in robotic cases compared with junior residents (78% vs 48%, p robotic case. Approximately 64% of residents reported that formal training in robotic surgery was important in residency training and 46% of residents indicated that robotic-assisted cases interfered with resident learning. Only 11% felt that robotic-assisted cases would replace conventional laparoscopic surgery in the future. This study illustrates that although the most residents

  4. Robot-Assisted Rehabilitation of Ankle Plantar Flexors Spasticity: A Three-Month Study with Proprioceptive Neuromuscular Facilitation

    Directory of Open Access Journals (Sweden)

    Zhihao Zhou

    2016-11-01

    Full Text Available In this paper, we aim to investigate the effect of Proprioceptive Neuromuscular Facilitation (PNF based rehabilitation for ankle plantar flexors spasticity by using a Robotic Ankle-foot Rehabilitation System (RARS. A modified robot-assisted system was proposed and seven post-stroke patients with hemiplegic spastic ankles participated a three-month of robotic PNF training. Their impaired sides were used as the experimental group while their unimpaired sides as the control group. A robotic intervention for the experimental group generally started from a two minutes passive stretching to warm-up or relax the soleus and gastrocnemius muscle and also ended with the same one. Then a PNF training session included 30 trails was activated between them. The rehabilitation trainings were carried out three times a week as an addition of their regular rehabilitation exercise. Passive ankle joint range of motion, resistance torque and stiffness were measured in both ankles before and after the intervention. The changes in Achilles' tendon length, walking speed, and lower limb function were also evaluated by the same physician or physiotherapist for each participant. Biomechanical measurements before interventions showed significant difference between the experimental group and the control group due to ankle spasticity. For the control group, there was no significant difference in the three months with no robotic intervention. But for the experimental group, passive dorsiflexion range of motion increased ( p0.05 . The robotic rehabilitation also improved the muscle strength ( p0.05 and fast walking speed ( p<0.05 . These results indicated that PNF based robotic intervention could significantly alleviate lower limb spasticity and improve the motor function in chronic stroke participant. The robotic system could potentially be used as an effective tool in post-stroke rehabilitation training.

  5. Investigating the Effects of Robot-Assisted Therapy among Children with Autism Spectrum Disorder using Bio-markers

    Science.gov (United States)

    Bharatharaj, Jaishankar; Huang, Loulin; Al-Jumaily, Ahmed; Elara, Mohan Rajesh; Krägeloh, Chris

    2017-09-01

    Therapeutic pet robots designed to help humans with various medical conditions could play a vital role in physiological, psychological and social-interaction interventions for children with autism spectrum disorder (ASD). In this paper, we report our findings from a robot-assisted therapeutic study conducted over seven weeks to investigate the changes in stress levels of children with ASD. For this study, we used the parrot-inspired therapeutic robot, KiliRo, we developed and investigated urinary and salivary samples of participating children to report changes in stress levels before and after interacting with the robot. This is a pioneering human-robot interaction study to investigate the effects of robot-assisted therapy using salivary samples. The results show that the bio-inspired robot-assisted therapy can significantly help reduce the stress levels of children with ASD.

  6. Facilitators and Barriers to Adopting Robotic-Assisted Surgery: Contextualizing the Unified Theory of Acceptance and Use of Technology

    Science.gov (United States)

    BenMessaoud, Christine; Kharrazi, Hadi; MacDorman, Karl F.

    2011-01-01

    Robotic-assisted surgical techniques are not yet well established among surgeon practice groups beyond a few surgical subspecialties. To help identify the facilitators and barriers to their adoption, this belief-elicitation study contextualized and supplemented constructs of the unified theory of acceptance and use of technology (UTAUT) in robotic-assisted surgery. Semi-structured individual interviews were conducted with 21 surgeons comprising two groups: users and nonusers. The main facilitators to adoption were Perceived Usefulness and Facilitating Conditions among both users and nonusers, followed by Attitude Toward Using Technology among users and Extrinsic Motivation among nonusers. The three main barriers to adoption for both users and nonusers were Perceived Ease of Use and Complexity, Perceived Usefulness, and Perceived Behavioral Control. This study's findings can assist surgeons, hospital and medical school administrators, and other policy makers on the proper adoption of robotic-assisted surgery and can guide future research on the development of theories and framing of hypotheses. PMID:21283719

  7. The value of contrast-enhanced laparoscopic ultrasound during robotic-assisted surgery for primary colorectal cancer

    DEFF Research Database (Denmark)

    Ellebaek, Signe Bremholm; Fristrup, Claus Wilki; Pless, Torsten

    2018-01-01

    AIM: The aim of this study was to assess the potential clinical value of contrast enhanced laparoscopic ultrasonography (CE-LUS) as a screening modality for liver metastases during robotic assisted surgery for primary colorectal cancer (CRC). METHOD: A prospective, descriptive (feasibility) study...... including 50 consecutive patients scheduled for robotic assisted surgery for primary CRC. CE-LUS was performed by 2 experienced specialists. Only patients without metastatic disease were included. Follow-up was obtained with contrast-enhanced CT imaging at 3 and 12 months postoperatively. RESULTS: Fifty......-up revealed no liver metastasis in any of the patients. CONCLUSION: CE-LUS did not increase the detection rate of occult liver metastasis during robotic assisted primary CRC surgery. The use of CE-LUS as a screening modality for detection of liver metastasis cannot be recommended based on this study...

  8. Kinematic modelling of a five-DOFs spatial manipulator used in robot-assisted surgery

    Directory of Open Access Journals (Sweden)

    Shakti Singh

    2016-09-01

    Full Text Available Since last three decades, research in the field of robot kinematics is boosted-up among different researchers worldwide. This is mainly due to their increased use in various challenging fields of engineering and science. One such challenging application is the use of master–slave concept in a robot-assisted surgery. The authors have already performed the kinematic study and gravity balancing of seven degrees-of-freedom (DOFs surgeon-side manipulator (Singh et al., 2015a, 2015b. To meet these challenging demands, the most important aspect of a robotic manipulator is to develop an accurate kinematic model. In this direction, different researchers in the literature have made significant contributions. Out of these, the most prominent one is D–H parameters method, which was proposed by Denavit and Hartenberg in 1955. In the present work, this method is applied to a five-DOFs spatial manipulator, named as patient-side manipulator, which tracks the motion of surgeon-side manipulator during a robot-assisted surgery. The prototype considered in this work is a spatial serial manipulator, being developed at CSIR-CSIO Chandigarh. Experimental validations are performed and results are found to be in close agreement.

  9. Reviewing effectiveness of ankle assessment techniques for use in robot-assisted therapy.

    Science.gov (United States)

    Zhang, Mingming; Davies, T Claire; Zhang, Yanxin; Xie, Shane

    2014-01-01

    This article provides a comprehensive review of studies that investigated ankle assessment techniques to better understand those that can be used in the real-time monitoring of rehabilitation progress for implementation in conjunction with robot-assisted therapy. Seventy-six publications published between January 1980 and August 2013 were selected based on eight databases. They were divided into two main categories (16 qualitative and 60 quantitative studies): 13 goniometer studies, 18 dynamometer studies, and 29 studies about innovative techniques. A total of 465 subjects participated in the 29 quantitative studies of innovative measurement techniques that may potentially be integrated in a real-time monitoring device, of which 19 studies included less than 10 participants. Results show that qualitative ankle assessment methods are not suitable for real-time monitoring in robot-assisted therapy, though they are reliable for certain patients, while the quantitative methods show great potential. The majority of quantitative techniques are reliable in measuring ankle kinematics and kinetics but are usually available only for use in the sagittal plane. Limited studies determine kinematics and kinetics in all three planes (sagittal, transverse, and frontal) where motions of the ankle joint and the subtalar joint actually occur.

  10. A multimodal imaging framework for enhanced robot-assisted partial nephrectomy guidance

    Science.gov (United States)

    Halter, Ryan J.; Wu, Xiaotian; Hartov, Alex; Seigne, John; Khan, Shadab

    2015-03-01

    Robot-assisted laparoscopic partial nephrectomies (RALPN) are performed to treat patients with locally confined renal carcinoma. There are well-documented benefits to performing partial (opposed to radical) kidney resections and to using robot-assisted laparoscopic (opposed to open) approaches. However, there are challenges in identifying tumor margins and critical benign structures including blood vessels and collecting systems during current RALPN procedures. The primary objective of this effort is to couple multiple image and data streams together to augment visual information currently provided to surgeons performing RALPN and ultimately ensure complete tumor resection and minimal damage to functional structures (i.e. renal vasculature and collecting systems). To meet this challenge we have developed a framework and performed initial feasibility experiments to couple pre-operative high-resolution anatomic images with intraoperative MRI, ultrasound (US) and optical-based surface mapping and kidney tracking. With these registered images and data streams, we aim to overlay the high-resolution contrast-enhanced anatomic (CT or MR) images onto the surgeon's view screen for enhanced guidance. To date we have integrated the following components of our framework: 1) a method for tracking an intraoperative US probe to extract the kidney surface and a set of embedded kidney markers, 2) a method for co-registering intraoperative US scans with pre-operative MR scans, and 3) a method for deforming pre-op scans to match intraoperative scans. These components have been evaluated through phantom studies to demonstrate protocol feasibility.

  11. Anticipation, Teamwork, and Cognitive Load: Chasing Efficiency during Robot-Assisted Surgery

    Science.gov (United States)

    Sexton, Kevin; Johnson, Amanda; Gotsch, Amanda; Hussein, Ahmed A.; Cavuoto, Lora; Guru, Khurshid A.

    2018-01-01

    Introduction Robot-assisted surgery (RAS) has changed the traditional operating room, occupying more space with equipment and isolating console surgeons away from the patients and their team. We aimed to evaluate how anticipation of surgical steps and familiarity between team members impacted efficiency and safety. Methods We analyzed recordings (video and audio) of 12 robot-assisted radical prostatectomies. Any requests between surgeon and the team members were documented and classified by personnel, equipment type, mode of communication, level of inconvenience in fulfilling the request, and anticipation. Surgical team members completed questionnaires assessing team familiarity and cognitive load (NASA-TLX). Predictors of team efficiency were assessed using Pearson correlation and stepwise linear regression. Results 1330 requests were documented of which 413 (31%) were anticipated. Anticipation correlated negatively with operative time resulting in overall 8% reduction of OR time. Team familiarity negatively correlated with inconveniences. Anticipation ratio, percent of requests that were nonverbal, and total request duration were significantly correlated with the console surgeons’ cognitive load (r=0.77, p=0.006; r=0.63, p=0.04; and r=0.70, p=0.02, respectively). Conclusions Anticipation and active engagement by the surgical team resulted in shorter operative time; and higher familiarity scores were associated with fewer inconveniences. Less anticipation and nonverbal requests were also associated with lower cognitive load for the console surgeon. Training efforts to increase anticipation and team familiarity can improve team efficiency during RAS. PMID:28689193

  12. Costs of Robotic-Assisted Versus Traditional Laparoscopy in Endometrial Cancer.

    Science.gov (United States)

    Vuorinen, Riikka-Liisa K; Mäenpää, Minna M; Nieminen, Kari; Tomás, Eija I; Luukkaala, Tiina H; Auvinen, Anssi; Mäenpää, Johanna U

    2017-10-01

    The purpose of this study was to compare the costs of traditional laparoscopy and robotic-assisted laparoscopy in the treatment of endometrial cancer. A total of 101 patients with endometrial cancer were randomized to the study and operated on starting from 2010 until 2013, at the Department of Obstetrics and Gynecology of Tampere University Hospital, Tampere, Finland. Costs were calculated based on internal accounting, hospital database, and purchase prices and were compared using intention-to-treat analysis. Main outcome measures were item costs and total costs related to the operation, including a 6-month postoperative follow-up. The total costs including late complications were 2160 &OV0556; higher in the robotic group (median for traditional 5823 &OV0556;, vs robot median 7983 &OV0556;, P costs for instruments and equipment as well as to more expensive operating room and postanesthesia care unit time. Traditional laparoscopy involved higher costs for operation personnel, general costs, medication used in the operation, and surgeon, although these costs were not substantial. There was no significant difference in in-patient stay, laboratory, radiology, blood products, or costs related to complications. According to this study, robotic-assisted laparoscopy is 37% more expensive than traditional laparoscopy in the treatment of endometrial cancer. The cost difference is mainly explained by amortization of the robot and its instrumentation.

  13. Prospective analysis of completely stentless robot-assisted pyeloplasty in children.

    Science.gov (United States)

    Casale, Pasquale; Lambert, Sarah

    2010-01-01

    Robot-assisted pyeloplasty (RAP) is emerging as an effective tool for treatment of ureteropelvic junction obstruction (UPJO) in the pediatric population. Typically stents are utilized for RAP and removed four weeks after the procedure. We present our prospective experience with stentless RAP. Twenty children between the ages of 12 and 113 months (mean age 56 months) underwent transperitoneal RAP for UPJO utilizing the DaVinci surgical system. Outcome measures included operative time, length of hospital stay, and resolution of obstruction by ultrasonography, magnetic resonance urography (MRU), and/or diuretic radionuclide imaging (DRI). All patients successfully underwent robot-assisted laparoscopic pyeloplasty without conversion to pure laparoscopy or open procedure. Mean operative time was 124.7 min with a mean console time of 82.3 min. The mean hospital stay was 18 h. Of the 20 patients, 13/20 (65%) had resolution or improvement in the degree of hydronephrosis. The other patients had no evidence of obstruction based upon follow-up MRU or DRI. Stentless RAP is a safe and effective option for surgical treatment of UPJO. A larger prospective long-term cohort is needed to confirm the safety and efficacy of the stentless approach.

  14. Robot-assisted laparoscopic partial nephrectomy: Current review of the technique and literature.

    Science.gov (United States)

    Singh, Iqbal

    2009-10-01

    To visit the operative technique and to review the current published English literature on the technique, and outcomes following robot-assisted laparoscopic partial nephrectomy (RPN). We searched the published English literature and the PubMed(()) for published series of 'robotic partial nephrectomy' (RPN) using the keywords; robot, robot-assisted laparoscopic partial nephrectomy, laparoscopic partial nephrectomy, partial nephrectomy and laparoscopic surgery. The search yielded 15 major selected series of 'robotic partial nephrectomy'; these were reviewed, tracked and analysed in order to determine the current status and role of RPN in the management of early renal neoplasm(s), as a minimally invasive surgical alternative to open partial nephrectomy. A review of the initial peri-operative outcome of the 350 cases of select series of RPN reported in published English literature revealed a mean operating time, warm ischemia time, estimated blood loss and hospital stay, of 191 minutes, 25 minutes, 162 ml and 2.95 days, respectively. The overall computed mean complication rate of RPN in the present select series was about 7.4%. RPN is a safe, feasible and effective minimally invasive surgical alternative to laparoscopic partial nephrectomy for early stage (T(1)) renal neoplasm(s). It has acceptable initial renal functional outcomes without the increased risk of major complications in experienced hands. Prospective randomised, controlled, comparative clinical trials with laparoscopic partial nephrectomy (LPN) are the need of the day. While the initial oncological outcomes of RPN appear to be favourable, long-term data is awaited.

  15. Robot-assisted endoscope guidance versus manual endoscope guidance in functional endonasal sinus surgery (FESS).

    Science.gov (United States)

    Eichhorn, Klaus Wolfgang; Westphal, Ralf; Rilk, Markus; Last, Carsten; Bootz, Friedrich; Wahl, Friedrich; Jakob, Mark; Send, Thorsten

    2017-10-01

    Having one hand occupied with the endoscope is the major disadvantage for the surgeon when it comes to functional endoscopic sinus surgery (FESS). Only the other hand is free to use the surgical instruments. Tiredness or frequent instrument changes can thus lead to shaky endoscopic images. We collected the pose data (position and orientation) of the rigid 0° endoscope and all the instruments used in 16 FESS procedures with manual endoscope guidance as well as robot-assisted endoscope guidance. In combination with the DICOM CT data, we tracked the endoscope poses and workspaces using self-developed tracking markers. All surgeries were performed once with the robot and once with the surgeon holding the endoscope. Looking at the durations required, we observed a decrease in the operating time because one surgeon doing all the procedures and so a learning curve occurred what we expected. The visual inspection of the specimens showed no damages to any of the structures outside the paranasal sinuses. Robot-assisted endoscope guidance in sinus surgery is possible. Further CT data, however, are desirable for the surgical analysis of a tracker-based navigation within the anatomic borders. Our marker-based tracking of the endoscope as well as the instruments makes an automated endoscope guidance feasible. On the subjective side, we see that RASS brings a relief for the surgeon.

  16. Tandem-robot assisted laparoscopic radical prostatectomy to improve the neurovascular bundle visualization: a feasibility study.

    Science.gov (United States)

    Han, Misop; Kim, Chunwoo; Mozer, Pierre; Schäfer, Felix; Badaan, Shadie; Vigaru, Bogdan; Tseng, Kenneth; Petrisor, Doru; Trock, Bruce; Stoianovici, Dan

    2011-02-01

    To examine the feasibility of image-guided navigation using transrectal ultrasound (TRUS) to visualize the neurovascular bundle (NVB) during robot-assisted laparoscopic radical prostatectomy (RALP). The preservation of the NVB during radical prostatectomy improves the postoperative recovery of sexual potency. The accompanying blood vessels in the NVB can serve as a macroscopic landmark to localize the microscopic cavernous nerves in the NVB. A novel, robotic transrectal ultrasound probe manipulator (TRUS Robot) and three-dimensional (3-D) reconstruction software were developed and used concurrently with the daVinci surgical robot (Intuitive Surgical, Inc., Sunnyvale, CA) in a tandem-robot assisted laparoscopic radical prostatectomy (T-RALP). After appropriate approval and informed consent were obtained, 3 subjects underwent T-RALP without associated complications. The TRUS Robot allowed a steady handling and remote manipulation of the TRUS probe during T-RALP. It also tracked the TRUS probe position accurately and allowed 3-D image reconstruction of the prostate and surrounding structures. Image navigation was performed by observing the tips of the daVinci surgical instruments in the live TRUS image. Blood vessels in the NVB were visualized using Doppler ultrasound. Intraoperative 3-D image-guided navigation in T-RALP is feasible. The use of TRUS during radical prostatectomy can potentially improve the visualization and preservation of the NVB. Further studies are needed to assess the clinical benefit of T-RALP. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Ambulatory movements, team dynamics and interactions during robot-assisted surgery.

    Science.gov (United States)

    Ahmad, Nabeeha; Hussein, Ahmed A; Cavuoto, Lora; Sharif, Mohamed; Allers, Jenna C; Hinata, Nobuyuki; Ahmad, Basel; Kozlowski, Justen D; Hashmi, Zishan; Bisantz, Ann; Guru, Khurshid A

    2016-07-01

    To analyse ambulatory movements and team dynamics during robot-assisted surgery (RAS), and to investigate whether congestion of the physical space associated with robotic technology led to workflow challenges or predisposed to errors and adverse events. With institutional review board approval, we retrospectively reviewed 10 recorded robot-assisted radical prostatectomies in a single operating room (OR). The OR was divided into eight zones, and all movements were tracked and described in terms of start and end zones, duration, personnel and purpose. Movements were further classified into avoidable (can be eliminated/improved) and unavoidable (necessary for completion of the procedure). The mean operating time was 166 min, of which ambulation constituted 27 min (16%). A total of 2 896 ambulatory movements were identified (mean: 290 ambulatory movements/procedure). Most of the movements were procedure-related (31%), and were performed by the circulating nurse. We identified 11 main pathways in the OR; the heaviest traffic was between the circulating nurse zone, transit zone and supply-1 zone. A total of 50% of ambulatory movements were found to be avoidable. More than half of the movements during RAS can be eliminated with an improved OR setting. More studies are needed to design an evidence-based OR layout that enhances access, workflow and patient safety. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  18. Endoscopic vision-based tracking of multiple surgical instruments during robot-assisted surgery.

    Science.gov (United States)

    Ryu, Jiwon; Choi, Jaesoon; Kim, Hee Chan

    2013-01-01

    Robot-assisted minimally invasive surgery is effective for operations in limited space. Enhancing safety based on automatic tracking of surgical instrument position to prevent inadvertent harmful events such as tissue perforation or instrument collisions could be a meaningful augmentation to current robotic surgical systems. A vision-based instrument tracking scheme as a core algorithm to implement such functions was developed in this study. An automatic tracking scheme is proposed as a chain of computer vision techniques, including classification of metallic properties using k-means clustering and instrument movement tracking using similarity measures, Euclidean distance calculations, and a Kalman filter algorithm. The implemented system showed satisfactory performance in tests using actual robot-assisted surgery videos. Trajectory comparisons of automatically detected data and ground truth data obtained by manually locating the center of mass of each instrument were used to quantitatively validate the system. Instruments and collisions could be well tracked through the proposed methods. The developed collision warning system could provide valuable information to clinicians for safer procedures. © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  19. Comparison of precision and speed in laparoscopic and robot-assisted surgical task performance.

    Science.gov (United States)

    Zihni, Ahmed; Gerull, William D; Cavallo, Jaime A; Ge, Tianjia; Ray, Shuddhadeb; Chiu, Jason; Brunt, L Michael; Awad, Michael M

    2018-03-01

    Robotic platforms have the potential advantage of providing additional dexterity and precision to surgeons while performing complex laparoscopic tasks, especially for those in training. Few quantitative evaluations of surgical task performance comparing laparoscopic and robotic platforms among surgeons of varying experience levels have been done. We compared measures of quality and efficiency of Fundamentals of Laparoscopic Surgery task performance on these platforms in novices and experienced laparoscopic and robotic surgeons. Fourteen novices, 12 expert laparoscopic surgeons (>100 laparoscopic procedures performed, no robotics experience), and five expert robotic surgeons (>25 robotic procedures performed) performed three Fundamentals of Laparoscopic Surgery tasks on both laparoscopic and robotic platforms: peg transfer (PT), pattern cutting (PC), and intracorporeal suturing. All tasks were repeated three times by each subject on each platform in a randomized order. Mean completion times and mean errors per trial (EPT) were calculated for each task on both platforms. Results were compared using Student's t-test (P task performance was slower on the robotic platform compared with laparoscopy. In comparisons of expert laparoscopists performing tasks on the laparoscopic platform and expert robotic surgeons performing tasks on the robotic platform, expert robotic surgeons demonstrated fewer errors during the PC task (P = 0.009). Robotic assistance provided a reduction in errors at all experience levels for some laparoscopic tasks, but no benefit in the speed of task performance. Robotic assistance may provide some benefit in precision of surgical task performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Robotic-assisted gastroplication in a morbidly obese adolescent: early improvement in metabolic and neurohormonal parameters

    Directory of Open Access Journals (Sweden)

    Valeria Calcaterra

    2012-12-01

    Full Text Available Bariatric surgery has to be considered in the management of severely obese adolescents when all conservative measures have been proven to be unresponsive. Short term metabolic and neurohormonal profile changes after robotic-assisted gastroplication are evaluated. The benefits and the usefulness of this surgical-reversal procedure in adolescent need to be defined. Fiveteen years old girl with body mass index 42.2 kg/m2, hyperinsulinism, hyperandrogenism, amenorrhea, polycystic ovarian syndrome, hypertension with left ventricular hypertrophy. Gastric volume after surgical procedure reduction was 80-100 mL. One month postoperatively significant weigh loss was obtained. Insulin levels, insulin-resistance, leptin and ghrelin concentration were substantially ameliorated. We can conclude that bariatric surgery should be considered for a minority of severely obese adolescents under the supervision of a multidisciplinary pediatric team. Our experience confirmed that the gastroplication is safe, feasible and effective and furthermore is a reversible technique. The early improvement of the obesity co-morbities is allowed. The increased surgical accuracy in robotic assistance could limit postoperative complications rate in obese adolescents.

  1. Robot-assisted ultrasound imaging: overview and development of a parallel telerobotic system.

    Science.gov (United States)

    Monfaredi, Reza; Wilson, Emmanuel; Azizi Koutenaei, Bamshad; Labrecque, Brendan; Leroy, Kristen; Goldie, James; Louis, Eric; Swerdlow, Daniel; Cleary, Kevin

    2015-02-01

    Ultrasound imaging is frequently used in medicine. The quality of ultrasound images is often dependent on the skill of the sonographer. Several researchers have proposed robotic systems to aid in ultrasound image acquisition. In this paper we first provide a short overview of robot-assisted ultrasound imaging (US). We categorize robot-assisted US imaging systems into three approaches: autonomous US imaging, teleoperated US imaging, and human-robot cooperation. For each approach several systems are introduced and briefly discussed. We then describe a compact six degree of freedom parallel mechanism telerobotic system for ultrasound imaging developed by our research team. The long-term goal of this work is to enable remote ultrasound scanning through teleoperation. This parallel mechanism allows for both translation and rotation of an ultrasound probe mounted on the top plate along with force control. Our experimental results confirmed good mechanical system performance with a positioning error of < 1 mm. Phantom experiments by a radiologist showed promising results with good image quality.

  2. Evolution of Robot-assisted ultrasound-guided breast biopsy systems

    Directory of Open Access Journals (Sweden)

    Mustafa Z. Mahmoud

    2018-01-01

    Full Text Available Robot-assisted ultrasound-guided breast biopsy combines ultrasound (US imaging with a robotic system for medical interventions. This study was designed to provide a literature review of a robotic US-guided breast biopsy system to delineate its efficacious impact on current medical practice. In addition, the strengths and limitations of this approach were also addressed. Articles published in the English language between 2000 and 2016 were appraised in this review. A wide range of systems that bind robotics with US imaging and guided breast biopsy were examined in this article. The fundamental safety and real-time imaging capabilities of US, together with the accuracy and maneuverability of robotic devices, is clearly an effective association with unmatched capabilities. Numerous experimental systems have obvious benefits over old-fashioned techniques, and the future of robot-assisted US-guided breast biopsy will be characterized by increasing levels of automation, and they hold tremendous possibility to impact doctor achievement, patient recovery, and clinical management.

  3. Peritoneal Tuberculosis After Robot-Assisted Laparoscopic Prostatectomy with Extended Lymph Node Dissection.

    Science.gov (United States)

    Saito, Suruga; Ito, Katsuhiro; Matsumoto, Keiyu; Tajima, Motofumi; Goto, Takayuki; Ito, Haruki; Manabe, Yumi; Mishina, Mutsuki; Okuno, Hiroshi

    2018-01-01

    Background: Peritoneal tuberculosis (TB) is a relatively uncommon presentation of extrapulmonary TB. Early diagnosis of peritoneal TB is difficult because of its nonspecific clinical manifestation such as abdominal pain, fever, or ascites. Especially early after surgery of abdomen or pelvis, these symptoms can be misdiagnosed as septic peritonitis. There are few reports of peritoneal TB as a postoperative complication of laparoscopic surgery. Here, we describe a first case of peritoneal TB after robot-assisted laparoscopic prostatectomy (RALP) with extended lymph node dissection. Case Presentation: A 78-year-old man presented 25 days after this surgery with fever and abdominal distension. Ultrasonography and computed tomography (CT) revealed massive abdominal ascites. Ascites sample was cloudy, with increased white blood cells and normal creatinine level. No anastomotic leak was found. Bacterial infection of a lymphocele was considered, and cefmetazole 2 g/day for 3 days was prescribed. Despite antibacterial therapy, fever persisted. Polymerase chain reaction testing of ascitic fluid was positive for Mycobacterium tuberculosis . The patient was effectively treated with anti-TB therapy. Conclusion: This is the first report of peritoneal TB as a postoperative complication of RALP with extended lymph node dissection. His preoperative chest CT showed granular shadows in left upper lung, indicating his old asymptomatic TB infection. Flare-up of TB can happen even after robot-assisted laparoscopic surgery, which is minimally invasive. Peritoneal TB must be considered especially when there is unexplained ascites unresponsive to antibiotics.

  4. Robot-assisted pyeloplasty for pelvi-ureteric junction obstruction of lower moiety in partial duplex system: A technical challenge

    Directory of Open Access Journals (Sweden)

    Girdhar S Bora

    2016-01-01

    Full Text Available Management of pelvi-ureteric junction obstruction (PUJO in a duplex system is technically challenging as dissection at the pelvis may jeopardize the vascularity of the normal moiety ureter. Anastomosing the pelvis to the one single ureter will have a risk of future development of stricture which then will risk both the moieties. Robotic assistance enables appropriate tissue dissection; minimal handling of normal ureter and precision in suturing, overcoming the potential challenges involved in the minimally invasive management of such complex cases. We report the feasibility and efficacy of robot-assisted laparoscopic pyeloplasty in such case.

  5. [Robot-assisted surgery - Progress or expensive toy? : Matched-pair comparative analysis of robot-assisted cholecystectomy vs. laparoscopic cholecystectomy].

    Science.gov (United States)

    Albrecht, R; Haase, D; Zippel, R; Koch, H; Settmacher, U

    2017-12-01

    By means of a matched-pair analysis comparing data obtained from laparoscopic cholecystectomy (LC) and robot-assisted laparoscopic cholecystectomy (RAC), the value of both methods as well as the advantages and disadvantages of both approaches were elucidated. The consideration was carried out by evaluation of postoperative surgical results, a cost analysis and a subjective survey of the patients using a questionnaire. Thus, from the 35 consecutive RAC, 35 (parallel) retrospectively matched pairs were established. Postoperative surgical results did not show any significant differences between LC and RAC. In the individual assessment by each patient, there were also no significant differences; however, there was a tendency towards the assessment of the RAC to be slightly worse. A striking difference was found with respect to the cost analysis at the time of surgery. The RAC operation alone is significantly more expensive compared to LC with respect to maintenance and acquisition costs. In addition, RAC can at present not be completely reimbursed under the current German diagnosis-related system. The postulated advantages of RAC comprise mainly the precise preparation within narrow confinements and the favorable ergonomic handling for the surgeon. The basic prerequisites are control of the costs and a reasonable reflection in the current reimbursement system.

  6. Needle-tissue interactive mechanism and steering control in image-guided robot-assisted minimally invasive surgery: a review.

    Science.gov (United States)

    Li, Pan; Yang, Zhiyong; Jiang, Shan

    2018-06-01

    Image-guided robot-assisted minimally invasive surgery is an important medicine procedure used for biopsy or local target therapy. In order to reach the target region not accessible using traditional techniques, long and thin flexible needles are inserted into the soft tissue which has large deformation and nonlinear characteristics. However, the detection results and therapeutic effect are directly influenced by the targeting accuracy of needle steering. For this reason, the needle-tissue interactive mechanism, path planning, and steering control are investigated in this review by searching literatures in the last 10 years, which results in a comprehensive overview of the existing techniques with the main accomplishments, limitations, and recommendations. Through comprehensive analyses, surgical simulation for insertion into multi-layer inhomogeneous tissue is verified as a primary and propositional aspect to be explored, which accurately predicts the nonlinear needle deflection and tissue deformation. Investigation of the path planning of flexible needles is recommended to an anatomical or a deformable environment which has characteristics of the tissue deformation. Nonholonomic modeling combined with duty-cycled spinning for needle steering, which tracks the tip position in real time and compensates for the deviation error, is recommended as a future research focus in the steering control in anatomical and deformable environments. Graphical abstract a Insertion force when the needle is inserted into soft tissue. b Needle deflection model when the needle is inserted into soft tissue [68]. c Path planning in anatomical environments [92]. d Duty-cycled spinning incorporated in nonholonomic needle steering [64].

  7. Utilizing Machine Learning and Automated Performance Metrics to Evaluate Robot-Assisted Radical Prostatectomy Performance and Predict Outcomes.

    Science.gov (United States)

    Hung, Andrew J; Chen, Jian; Che, Zhengping; Nilanon, Tanachat; Jarc, Anthony; Titus, Micha; Oh, Paul J; Gill, Inderbir S; Liu, Yan

    2018-05-01

    Surgical performance is critical for clinical outcomes. We present a novel machine learning (ML) method of processing automated performance metrics (APMs) to evaluate surgical performance and predict clinical outcomes after robot-assisted radical prostatectomy (RARP). We trained three ML algorithms utilizing APMs directly from robot system data (training material) and hospital length of stay (LOS; training label) (≤2 days and >2 days) from 78 RARP cases, and selected the algorithm with the best performance. The selected algorithm categorized the cases as "Predicted as expected LOS (pExp-LOS)" and "Predicted as extended LOS (pExt-LOS)." We compared postoperative outcomes of the two groups (Kruskal-Wallis/Fisher's exact tests). The algorithm then predicted individual clinical outcomes, which we compared with actual outcomes (Spearman's correlation/Fisher's exact tests). Finally, we identified five most relevant APMs adopted by the algorithm during predicting. The "Random Forest-50" (RF-50) algorithm had the best performance, reaching 87.2% accuracy in predicting LOS (73 cases as "pExp-LOS" and 5 cases as "pExt-LOS"). The "pExp-LOS" cases outperformed the "pExt-LOS" cases in surgery time (3.7 hours vs 4.6 hours, p = 0.007), LOS (2 days vs 4 days, p = 0.02), and Foley duration (9 days vs 14 days, p = 0.02). Patient outcomes predicted by the algorithm had significant association with the "ground truth" in surgery time (p algorithm in predicting, were largely related to camera manipulation. To our knowledge, ours is the first study to show that APMs and ML algorithms may help assess surgical RARP performance and predict clinical outcomes. With further accrual of clinical data (oncologic and functional data), this process will become increasingly relevant and valuable in surgical assessment and training.

  8. Accuracy and feasibility of frameless stereotactic and robot-assisted CT-based puncture in interventional radiology. A comparative phantom study

    International Nuclear Information System (INIS)

    Stoffner, R.; Widmann, G.; Bale, R.; Augschoell, C.; Boehler, D.

    2009-01-01

    Purpose: To compare the accuracy of frameless stereotactic and robot-assisted puncture in vitro based on computed tomography (CT) imaging with a slice thickness of 1, 3, and 5 mm. Materials and Methods: 300 punctures were carried out with help of the Atlas aiming device guided by the optical navigation system Stealth Station TREONplus and 150 punctures were guided by the robotic assistance system Innomotion. Conically shaped rods were punctured with Kirschner wires. The accuracy was evaluated on the basis of control CTs by measuring the Euclidean distance between the wire tip and target and the normal distance between the target and wire. Results: With the Stealth Station a mean Euclidean distance of 1.94±0.912, 2.2±1.136, and 2.74±1.166 mm at a slice thickness of 1, 3 and 5 mm, respectively, was reached. The mean normal distance was 1.64±0.919, 1.84±1.189, and 2.48±1.196 mm, respectively. The Innomotion system resulted in a mean Euclidean distance of 1.69±0.772, 1.91±0.673, and 2.30±0.881 mm, respectively, while the mean normal distance was (1.42±0.78), 1.60±0.733, and 1.98±1.002 mm, respectively. A statistical significance between accuracies with both systems with 1 mm and 3 mm slices could not be detected (p > 0.05). At a slice thickness of 5 mm, the robot was significantly more accurate, but not as accurate as when using thinner slices (p < 0.05). The procedure time is longer for the Innomotion system (∝30 vs. ∝18 min), and the practicability is higher with the Stealth Station. (orig.)

  9. Robotic Assisted Radical Cystoprostatectomy and Intracorporeal Ileal Conduit Urinary Diversion for a Kidney Transplant Recipient

    Directory of Open Access Journals (Sweden)

    Peter A. Caputo

    Full Text Available ABSTRACT Introduction and Objectives: Robotic assisted radical cystectomy (RARC is an alternative to open radical cystectomy. As experience is gained with the RARC approach the technique is being applied to more complex surgical cases. We describe here our technique for RARC with intracorporeal ileal conduit urinary diversion for a renal transplant recipient. Materials and Methods: The patient is a 60-year old man with high-grade muscle invasive bladder cancer. He has a history of renal failure due to polycystic kidney disease and received a deceased donor renal transplant in 2008. His hospital course at time of transplant was complicated by low-level BK virus viremia. Interestingly his trans-urethral bladder tumor resection specimen at time of bladder cancer diagnosis stained positive for SV40. His native kidneys were anuric so bilateral laparoscopic nephrectomy was performed in a staged fashion 2 weeks prior to RARC. Our surgical technique utilizes 6 trocars, of note a 12-mm assistant trocar is placed 1 cm superior to the pubic symphysis, and this trocar is solely used to pass a laparoscopic stapler to facilitate the excision of the ileal segment and the stapled enteric anastomosis. Surgical steps include: identification of native ureters bilaterally (removed en bloc with the bladder specimen; identification of the transplanted ureter at the right bladder dome; posterior bladder and prostate dissection along Denonvilliers’ fascia; development of the space of Retzius; ligation and transection of the bladder and prostate vascular bundles; apical prostate dissection and transection of urethra; left pelvic lymphadenectomy; ilium resection for creation of the ileal conduit; stapled enteric anastomosis; ureteroileal anastomosis; maturation of the ileal conduit stoma. Results: The surgery had no intraoperative complications. Operative time was 443 minutes (7.4 hours. Estimated blood loss was 250 cc. Length of hospital stay was 5 days. The patient

  10. Outcomes of complex robot-assisted extravesical ureteral reimplantation in the pediatric population.

    Science.gov (United States)

    Arlen, Angela M; Broderick, Kristin M; Travers, Curtis; Smith, Edwin A; Elmore, James M; Kirsch, Andrew J

    2016-06-01

    While open ureteral reimplantation remains the gold standard for surgical treatment of vesicoureteral reflux (VUR), minimally invasive approaches offer potential benefits. This study evaluated the outcomes of children undergoing complex robot-assisted laparoscopic ureteral reimplantation (RALUR) for failed previous anti-reflux surgery, complex anatomy, or ureterovesical junction obstruction (UVJO), and compared them with patients undergoing open extravesical repair. Children undergoing complex RALUR or open extravesical ureteral reimplantation (OUR) were identified. Reimplantation was classified as complex if ureters: 1) had previous anti-reflux surgery, 2) required tapering and/or dismembering, or 3) had associated duplication or diverticulum. Seventeen children underwent complex RALUR during a 24-month period, compared with 41 OUR. The mean follow-up was 16.6 ± 6.5 months. The RALUR children were significantly older (9.3 ± 3.7 years) than the OUR patients (3.1 ± 2.7 years; P urinary tract infection compared with a single child (5.9%) undergoing RALUR (P = 1.00). There was no significant difference in complication rate between the two groups (12.2% OUR versus 11.8% RALUR; P = 1.00). A postoperative cystogram was performed in the majority of RALUR patients, with no persistent VUR detected, and one child (6.7%) was diagnosed with contralateral reflux. Reported VUR resolution rates following robot-assisted ureteral reimplantation are varied. In the present series, children undergoing RALUR following failed previous anti-reflux surgery, with complex anatomy, or UVJO experienced a shorter length of stay but had similar analgesic requirements to those undergoing open repair. Radiographic, clinical success rates and complication risk were comparable. This study had several limitations, aside from lack of randomization. Analgesic use was limited to an inpatient setting, and pain scores were not assessed. Not all children underwent a postoperative VCUG, so

  11. Does robot-assisted gait training ameliorate gait abnormalities in multiple sclerosis? A pilot randomized-control trial.

    Science.gov (United States)

    Straudi, S; Benedetti, M G; Venturini, E; Manca, M; Foti, C; Basaglia, N

    2013-01-01

    Gait disorders are common in multiple sclerosis (MS) and lead to a progressive reduction of function and quality of life. Test the effects of robot-assisted gait rehabilitation in MS subjects through a pilot randomized-controlled study. We enrolled MS subjects with Expanded Disability Status Scale scores within 4.5-6.5. The experimental group received 12 robot-assisted gait training sessions over 6 weeks. The control group received the same amount of conventional physiotherapy. Outcomes measures were both biomechanical assessment of gait, including kinematics and spatio-temporal parameters, and clinical test of walking endurance (six-minute walk test) and mobility (Up and Go Test). 16 subjects (n = 8 experimental group, n = 8 control group) were included in the final analysis. At baseline the two groups were similar in all variables, except for step length. Data showed walking endurance, as well as spatio-temporal gait parameters improvements after robot-assisted gait training. Pelvic antiversion and reduced hip extension during terminal stance ameliorated after aforementioned intervention. Robot-assisted gait training seems to be effective in increasing walking competency in MS subjects. Moreover, it could be helpful in restoring the kinematic of the hip and pelvis.

  12. Comparison of Perioperative Outcomes of Total Laparoscopic and Robotically Assisted Hysterectomy for Benign Pathology during Introduction of a Robotic Program

    Directory of Open Access Journals (Sweden)

    Gokhan Sami Kilic

    2011-01-01

    Full Text Available Study Objective. Prospectively compare outcomes of robotically assisted and laparoscopic hysterectomy in the process of implementing a new robotic program. Design. Prospectively comparative observational nonrandomized study. Design Classification. II-1. Setting. Tertiary caregiver university hospital. Patients. Data collected consecutively 24 months, 34 patients underwent laparoscopic hysterectomy, 25 patients underwent robotic hysterectomy, and 11 patients underwent vaginal hysterectomy at our institution. Interventions. Outcomes of robotically assisted, laparoscopic, and vaginal complex hysterectomies performed by a single surgeon for noncancerous indications. Measurements and Main Results. Operative times were 208.3±59.01 minutes for laparoscopic, 286.2±82.87 minutes for robotic, and 163.5±61.89 minutes for vaginal (<.0001. Estimated blood loss for patients undergoing laparoscopic surgery was 242.7±211.37 cc, 137.4±107.50 cc for robotic surgery, and 243.2±127.52 cc for vaginal surgery (=0.05. The mean length of stay ranged from 1.8 to 2.3 days for the 3 methods. Association was significant for uterine weight (=0.0043 among surgery methods. Conclusion. Robotically assisted hysterectomy is feasible with low morbidity, a shorter hospital stay, and less blood loss. This suggests that robotic assistance facilitates a minimally invasive approach for patients with larger uterine size even during implementing a new robotic program.

  13. Initial consecutive 125 cases of robotic assisted laparoscopic radical prostatectomy performed in Ireland's first robotic radical prostatectomy centre.

    LENUS (Irish Health Repository)

    Bouchier-Hayes, D M

    2012-03-01

    We examined the patient characteristics, operative proceedings and the outcomes of the initial series of 125 cases of robot-assisted laparoscopic radical prostatectomy (RALRP) in an independent hospital in Ireland, performed by two surgeons using the da Vinci(®) surgical system.

  14. Retention of robot-assisted surgical skills in urological surgeons acquired using Mimic dV-Trainer.

    Science.gov (United States)

    Teishima, Jun; Hattori, Minoru; Inoue, Shogo; Ikeda, Kenichiro; Hieda, Keisuke; Ohara, Shinya; Egi, Hiroyuki; Ohdan, Hideki; Matsubara, Akio

    2014-07-01

    We assess the retention of robot-assisted surgical skills among urologic surgeons. The robot-assisted surgery skills of 20 urologic surgeons were assessed using a Mimic dV-Trainer program (Mimic Technologies, Inc., Seattle, WA) consisting of 6 tasks. These 20 surgeons had no previous experience either using the Mimic dV-Trainer or acting as the main surgeon in robot-assisted surgery. The surgeons completed the program 4 times in a row; after 1 year, they completed it again for a fifth time. Performance scores were recorded using the Mimic dV-Trainer's built-in algorithm. For all 6 tasks, there were significant improvements to the scores in the fourth trials compared with those in the first trials. The scores in the fifth trials did not significantly decline compared with those in the fourth trials. There was no significant difference between the fifth trial scores of surgeons with laparoscopic surgery skills/experience and those without. Our results indicate that fundamental robot-assisted surgical skills can be retained in the long-term after they are acquired.

  15. Towards free 3D end-point control for robotic-assisted human reaching using binocular eye tracking.

    Science.gov (United States)

    Maimon-Dror, Roni O; Fernandez-Quesada, Jorge; Zito, Giuseppe A; Konnaris, Charalambos; Dziemian, Sabine; Faisal, A Aldo

    2017-07-01

    Eye-movements are the only directly observable behavioural signals that are highly correlated with actions at the task level, and proactive of body movements and thus reflect action intentions. Moreover, eye movements are preserved in many movement disorders leading to paralysis (or amputees) from stroke, spinal cord injury, Parkinson's disease, multiple sclerosis, and muscular dystrophy among others. Despite this benefit, eye tracking is not widely used as control interface for robotic interfaces in movement impaired patients due to poor human-robot interfaces. We demonstrate here how combining 3D gaze tracking using our GT3D binocular eye tracker with custom designed 3D head tracking system and calibration method enables continuous 3D end-point control of a robotic arm support system. The users can move their own hand to any location of the workspace by simple looking at the target and winking once. This purely eye tracking based system enables the end-user to retain free head movement and yet achieves high spatial end point accuracy in the order of 6 cm RMSE error in each dimension and standard deviation of 4 cm. 3D calibration is achieved by moving the robot along a 3 dimensional space filling Peano curve while the user is tracking it with their eyes. This results in a fully automated calibration procedure that yields several thousand calibration points versus standard approaches using a dozen points, resulting in beyond state-of-the-art 3D accuracy and precision.

  16. Acoustic Emission Based In-process Monitoring in Robot Assisted Polishing

    DEFF Research Database (Denmark)

    Pilny, Lukas; Bissacco, Giuliano; De Chiffre, Leonardo

    The applicability of acoustic emission (AE) measurements for in-process monitoring in the Robot Assisted Polishing (RAP) process was investigated. Surface roughness measurements require interruption of the process, proper surface cleaning and measurements that sometimes necessitate removal...... improving the efficiency of the process. It also allows for intelligent process control and generally enhances the robustness and reliability of the automated RAP system in industrial applications....... of the part from the machine tool. In this study, development of surface roughness during polishing rotational symmetric surfaces by the RAP process was inferred from AE measurements. An AE sensor was placed on a polishing tool, and a cylindrical rod of Vanadis 4E steel having an initial turned surface...

  17. The effect of a robot-assisted surgical system on the kinematics of user movements.

    Science.gov (United States)

    Nisky, Ilana; Hsieh, Michael H; Okamura, Allison M

    2013-01-01

    Teleoperated robot-assisted surgery (RAS) offers many advantages over traditional minimally invasive surgery. However, RAS has not yet realized its full potential, and it is not clear how to optimally train surgeons to use these systems. We hypothesize that the dynamics of the master manipulator impact the ability of users to make desired movements with the robot. We compared freehand and teleoperated movements of novices and experienced surgeons. To isolate the effects of dynamics from procedural knowledge, we chose simple movements rather than surgical tasks. We found statistically significant effects of teleoperation and user expertise in several aspects of motion, including target acquisition error, movement speed, and movement smoothness. Such quantitative assessment of human motor performance in RAS can impact the design of surgical robots, their control, and surgeon training methods, and eventually, improve patient outcomes.

  18. Measuring the Latency of an Augmented Reality System for Robot-Assisted Minimally Invasive Surgery

    DEFF Research Database (Denmark)

    Jørgensen, Martin Kibsgaard; Kraus, Martin

    2017-01-01

    Minimal latency is important for augmented reality systems and teleoperation interfaces as even small increases in latency can affect user performance. Previously, we have developed an augmented reality system that can overlay stereoscopic video streams with computer graphics in order to improve....... The latency of the da Vinci S surgical system was on average 62 ms. None of the components of our overlay system (separately or combined) significantly affected the latency. However, the latency of the assistant's monitor increased by 14 ms. Passing the video streams through CPU or GPU memory increased...... visual communication in training for robot-assisted minimally invasive surgery with da Vinci surgical systems. To make sure that our augmented reality system provides the best possible user experience, we investigated the video latency of the da Vinci surgical system and how the components of our system...

  19. Iatrogenic Lower Extremity Subcutaneous Emphysema after Prolonged Robotic-Assisted Hysterectomy

    Directory of Open Access Journals (Sweden)

    Monica Hagan Vetter

    2015-01-01

    Full Text Available Subcutaneous emphysema is a known complication of carbon dioxide insufflation, an essential component of laparoscopy. The literature contains reports of hypercarbia, pneumothorax, or pneumomediastinum. However, isolated lower extremity subcutaneous emphysema remains a seldom-reported complication. We report a case of unilateral lower extremity subcutaneous emphysema following robotic-assisted hysterectomy, bilateral salpingooophorectomy, staging, and anterior/posterior colporrhaphy for carcinosarcoma and vaginal prolapse. On postoperative day 1, the patient developed tender crepitus and bruising of her right ankle. Radiography confirmed presence of subcutaneous air. Vital signs and laboratory findings were unremarkable. Her symptoms spontaneously improved over time, and she was discharged in good condition on day 2. In stable patients with postoperative extremity swelling or pain with crepitus on exam, the diagnosis of iatrogenic subcutaneous emphysema must be considered.

  20. Robot-assisted ligation of bronchial artery could be an alternative to embolization.

    Science.gov (United States)

    Pochulu, Bruno; Sarsam, Omar; Peillon, Christophe; Baste, Jean-Marc

    2018-03-01

    A 37-year-old patient presented with a self-limiting episode of moderate haemoptysis. Contrast-enhanced chest computed tomography showed a tortuous and dilated right bronchial artery arising from the descending aorta at the level of T6. Therapeutic angiography was attempted, but in the presence of spinal artery arising from the bronchial artery in question, selective embolization was contraindicated due to risk of spinal cord ischaemia. After a multidisciplinary meeting, it was decided to attempt surgery to ligate this pathological artery. We performed minimally invasive robot-assisted ligation of this pathological artery. The postoperative course was uneventful with good clinical and radiological outcome at 3-month follow-up. A minimally invasive approach provides a real alternative to embolization and could be a therapeutic option.

  1. [Robotic-assisted minimally invasive abdominothoracal oesophageal resection with intrathoracic anastomosis].

    Science.gov (United States)

    Egberts, J-H; Aselmann, H; Schafmayer, C; Jünemann, K-P; Becker, T

    2014-02-01

    Ivor Lewis oesophagectomy is one of the approaches used worldwide for treating oesophageal cancer. The adoption of minimally invasive oesophagectomy has increased worldwide since its first description more than 15 years ago. However, minimally invasive oesophagectomy with a chest anastomosis has advantages. By using a four-arm robotic platform, not only the preparation of the gastric tube and mobilisation of the oesophagus but also the intrathoracic anastomosis of the oesophagogastrostomy can be performed in a comfortable and safe way. The indication for oesophageal resection is oesophageal cancer. The operative procedure comprises robotic-assisted abdominothoracal oesophageal resection with reconstruction by a gastric tube and intrathoracic anastomosis (Ivor Lewis procedure). Robotic abdominal and thoracic minimally invasive esophagectomy is feasible, and safe with a complete lymph node dissection. Especially the intrathoracic anastomosis of the oesophagogastrostomy can be performed in a comfortable and safe way. Georg Thieme Verlag KG Stuttgart · New York.

  2. Consistency of performance of robot-assisted surgical tasks in virtual reality.

    Science.gov (United States)

    Suh, I H; Siu, K-C; Mukherjee, M; Monk, E; Oleynikov, D; Stergiou, N

    2009-01-01

    The purpose of this study was to investigate consistency of performance of robot-assisted surgical tasks in a virtual reality environment. Eight subjects performed two surgical tasks, bimanual carrying and needle passing, with both the da Vinci surgical robot and a virtual reality equivalent environment. Nonlinear analysis was utilized to evaluate consistency of performance by calculating the regularity and the amount of divergence in the movement trajectories of the surgical instrument tips. Our results revealed that movement patterns for both training tasks were statistically similar between the two environments. Consistency of performance as measured by nonlinear analysis could be an appropriate methodology to evaluate the complexity of the training tasks between actual and virtual environments and assist in developing better surgical training programs.

  3. Towards Robot-Assisted Echocardiographic Monitoring in Catheterization Laboratories : Usability-Centered Manipulator for Transesophageal Echocardiography.

    Science.gov (United States)

    Pahl, Christina; Ebelt, Henning; Sayahkarajy, Mostafa; Supriyanto, Eko; Soesanto, Amiliana

    2017-08-15

    This paper proposes a robotic Transesophageal Echocardiography (TOE) system concept for Catheterization Laboratories. Cardiovascular disease causes one third of all global mortality. TOE is utilized to assess cardiovascular structures and monitor cardiac function during diagnostic procedures and catheter-based structural interventions. However, the operation of TOE underlies various conditions that may cause a negative impact on performance, the health of the cardiac sonographer and patient safety. These factors have been conflated and evince the potential of robot-assisted TOE. Hence, a careful integration of clinical experience and Systems Engineering methods was used to develop a concept and physical model for TOE manipulation. The motion of different actuators of the fabricated motorized system has been tested. It is concluded that the developed medical system, counteracting conflated disadvantages, represents a progressive approach for cardiac healthcare.

  4. Anastomotic complications after robot-assisted laparoscopic and open radical prostatectomy

    DEFF Research Database (Denmark)

    Jacobsen, André; Berg, Kasper Drimer; Iversen, Peter

    2016-01-01

    Objective Anastomotic complications are well known after radical prostatectomy (RP). The vesicourethral anastomotic technique is handled differently between open and robotic RP. The aim of the study was to investigate whether the frequency of anastomotic leakages and strictures differed between...... patients undergoing retropubic radical prostatectomy (RRP) and robot-assisted radical prostatectomy (RARP) and to identify risk factors associated with these complications. Materials and methods The study included 735 consecutive patients who underwent RRP (n = 499) or RARP (236) at the Department...... of Urology, Rigshospitalet, Denmark, in a complete 3 year period from 2010 to 2012. Univariate and multivariate logistic regression analysis was used to analyse associations between surgical procedure (RRP vs RARP) and anastomotic complications. Analyses included age, smoking status, diabetes, hypertension...

  5. Robotic-assisted laparoscopic hysterectomy seems safe in women with early-stage endometrial cancer

    DEFF Research Database (Denmark)

    Herling, Suzanne Forsyth; Havemann, Maria Cecilie; Palle, Connie

    2015-01-01

    INTRODUCTION: Robotic surgery is increasingly used in the management of endometrial cancer; and although it is known that minimally invasive surgery reduces post-operative morbidity, the outcomes of this novel treatment should be monitored carefully. The aim of this study was to examine...... the incidence of complications according to the Clavien-Dindo scale after robotic-assisted laparoscopic hysterectomy (RALH) for early-stage endometrial cancer and atypical complex hyperplasia. The Clavien-Dindo scale grades the severity of complications. METHODS: This was a retrospective, descriptive cohort...... study of 235 women with endometrial cancer or atypical complex hyperplasia who had RALH. Surgeries were stratified into two groups: with or without pelvic lymphadenectomy. RESULTS: A total of 6% developed a grade 3 or higher complication with no significant difference (p = 0.24) between the groups...

  6. Early biochemical recurrence, urinary continence and potency outcomes following robot-assisted radical prostatectomy

    DEFF Research Database (Denmark)

    Berg, Kasper Drimer; Thomsen, Frederik Birkebæk; Hvarness, Helle

    2014-01-01

    OBJECTIVE: The aim of this study was to describe recovery of urinary continence and potency and report oncological and functional outcomes using the survival, continence and potency (SCP) system for patients undergoing robot-assisted radical prostatectomy (RARP). MATERIAL AND METHODS: From 2009...... with preoperative ESI, 77.6% (67.9-86.1) and 34.4% (24.1-47.5) maintained ESI 12 months postoperatively after bilateral and unilateral nerve-sparing surgery (NS), respectively. NS (p .... Using the SCP system and defining potency as ESI, functional and oncological success 12 months after surgery was achieved in 69 out of 135 (51.1%) preoperative continent and potent patients who underwent unilateral or bilateral NS, and did not require adjuvant treatment; when defining potency as IIEF...

  7. Percutaneous Sacroiliac Screw Placement: A Prospective Randomized Comparison of Robot-assisted Navigation Procedures with a Conventional Technique

    Science.gov (United States)

    Wang, Jun-Qiang; Wang, Yu; Feng, Yun; Han, Wei; Su, Yong-Gang; Liu, Wen-Yong; Zhang, Wei-Jun; Wu, Xin-Bao; Wang, Man-Yi; Fan, Yu-Bo

    2017-01-01

    Background: Sacroiliac (SI) screw fixation is a demanding technique, with a high rate of screw malposition due to the complex pelvic anatomy. TiRobot™ is an orthopedic surgery robot which can be used for SI screw fixation. This study aimed to evaluate the accuracy of robot-assisted placement of SI screws compared with a freehand technique. Methods: Thirty patients requiring posterior pelvic ring stabilization were randomized to receive freehand or robot-assisted SI screw fixation, between January 2016 and June 2016 at Beijing Jishuitan Hospital. Forty-five screws were placed at levels S1 and S2. In both methods, the primary end point screw position was assessed and classified using postoperative computed tomography. Fisher's exact probability test was used to analyze the screws’ positions. Secondary end points, such as duration of trajectory planning, surgical time after reduction of the pelvis, insertion time for guide wire, number of guide wire attempts, and radiation exposure without pelvic reduction, were also assessed. Results: Twenty-three screws were placed in the robot-assisted group and 22 screws in the freehand group; no postoperative complications or revisions were reported. The excellent and good rate of screw placement was 100% in the robot-assisted group and 95% in the freehand group. The P value (0.009) showed the same superiority in screw distribution. The fluoroscopy time after pelvic reduction in the robot-assisted group was significantly shorter than that in the freehand group (median [Q1, Q3]: 6.0 [6.0, 9.0] s vs. median [Q1, Q3]: 36.0 [21.5, 48.0] s; χ2 = 13.590, respectively, P < 0.001); no difference in operation time after reduction of the pelvis was noted (χ2 = 1.990, P = 0.158). Time for guide wire insertion was significantly shorter for the robot-assisted group than that for the freehand group (median [Q1, Q3]: 2.0 [2.0, 2.7] min vs. median [Q1, Q3]: 19.0 [15.5, 45.0] min; χ2 = 20.952, respectively, P < 0.001). The number of guide

  8. Robot-assisted radical cystectomy with intracorporeal neobladder diversion: The Karolinska experience.

    Science.gov (United States)

    Collins, Justin W; Sooriakumaran, P; Sanchez-Salas, R; Ahonen, R; Nyberg, T; Wiklund, N P; Hosseini, A

    2014-07-01

    The aim of this report is to describe our surgical technique of totally intracorporeal robotic assisted radical cystectomy (RARC) with neobladder formation. Between December 2003 and March 2013, a total of 147 patients (118 male, 29 female) underwent totally intracorporeal RARC for urinary bladder cancer. We also performed a systematic search of Medline, Embase and PubMed databases using the terms RARC, robotic cystectomy, robot-assisted, totally intracorporeal RARC, intracorporeal neobladder, intracorporeal urinary diversion, oncological outcomes, functional outcomes, and complication rates. The mean age of our patients was 64 years (range 37-87). On surgical pathology 47% had pT1 or less disease, 27% had pT2, 16% had pT3 and 10% had pT4. The mean number of lymph nodes removed was 21 (range 0-60). 24% of patients had lymph node positive dAQ1isease. Positive surgical margins occurred in 6 cases (4%). Mean follow-up was 31 months (range 4-115 months). Two patients (1.4%) died within 90 days of their operation. Using Kaplan-Meier analysis, overall survival and cancer specific survival at 60 months was 68% and 69.6%, respectively. 80 patients (54%) received a continent diversion with totally intracorporeal neobladder formation. In the neobladder subgroup median total operating time was 420 minutes (range 265-760). Daytime continence and satisfactory sexual function or potency at 12 months ranged between 70-90% in both men and women. Our experience with totally intracorporeal RARC demonstrates acceptable oncological and functional outcomes that suggest this is a viable alternative to open radical cystectomy.

  9. An actuated force feedback-enabled laparoscopic instrument for robotic-assisted surgery.

    Science.gov (United States)

    Moradi Dalvand, Mohsen; Shirinzadeh, Bijan; Shamdani, Amir Hossein; Smith, Julian; Zhong, Yongmin

    2014-03-01

    Robotic-assisted minimally invasive surgery systems not only have the advantages of traditional laparoscopic instruments but also have other important advantages, including restoring the surgeon's hand-eye coordination and improving the surgeon's precision by filtering hand tremors. Unfortunately, these benefits have come at the expense of the surgeon's ability to feel. Various solutions for restoring this feature have been proposed. An actuated modular force feedback-enabled laparoscopic instrument was proposed that is able to measure tip-tissue lateral interaction forces as well as normal grasping forces. The instrument has also the capability to adjust the grasping direction inside the patient body. In order to measure the interaction forces, strain gauges were employed. A series of finite element analyses were performed to gain an understanding of the actual magnitude of surface strains where gauges are applied. The strain gauge bridge configurations were calibrated. A series of experiments was conducted and the results were analysed. The modularity feature of the proposed instrument makes it interchangeable between various tip types of different functionalities (e.g. cutter, grasper, dissector). Calibration results of the strain gauges incorporated into the tube and at the base of the instrument presented the monotonic responses for these strain gauge configurations. Experimental results from tissue probing and tissue characterization experiments verified the capability of the proposed instrument in measuring lateral probing forces and characterizing artificial tissue samples of varying stiffness. The proposed instrument can improve the quality of palpation and characterization of soft tissues of varying stiffness by restoring sense of touch in robotic assisted minimally invasive surgery operations. Copyright © 2013 John Wiley & Sons, Ltd.

  10. How to set up a robotic-assisted laparoscopic surgery center and training of staff.

    Science.gov (United States)

    Lenihan, John P

    2017-11-01

    The use of computers to assist surgeons in the operating room has been an inevitable evolution in the modern practice of surgery. Robotic-assisted surgery has been evolving now for over two decades and has finally matured into a technology that has caused a monumental shift in the way gynecologic surgeries are performed. Prior to robotics, the only minimally invasive options for most Gynecologic (GYN) procedures including hysterectomies were either vaginal or laparoscopic approaches. However, even with over 100 years of vaginal surgery experience and more than 20 years of laparoscopic advancements, most gynecologic surgeries in the United States were still performed through an open incision. However, this changed in 2005 when the FDA approved the da Vinci Surgical Robotic System tm for use in gynecologic surgery. Over the last decade, the trend for gynecologic surgeries has now dramatically shifted to less open and more minimally invasive procedures. Robotic-assisted surgeries now include not only hysterectomy but also most all other commonly performed gynecologic procedures including myomectomies, pelvic support procedures, and reproductive surgeries. This success, however, has not been without controversies, particularly around costs and complications. The evolution of computers to assist surgeons and make minimally invasive procedures more common is clearly a trend that is not going away. It is now incumbent on surgeons, hospitals, and medical societies to determine the most cost-efficient and productive use for this technology. This process is best accomplished by developing a Robotics Program in each hospital that utilizes robotic surgery. Copyright © 2017. Published by Elsevier Ltd.

  11. In vivo kinematics of a robot-assisted uni- and multi-compartmental knee arthroplasty.

    Science.gov (United States)

    Watanabe, Toshifumi; Abbasi, Ali Z; Conditt, Michael A; Christopher, Jennifer; Kreuzer, Stefan; Otto, Jason K; Banks, Scott A

    2014-07-01

    There is great interest in providing reliable and durable treatments for one- and two-compartment arthritic degeneration of the cruciate-ligament intact knee. One approach is to resurface only the diseased compartments with discrete unicompartmental components, retaining the undamaged compartment(s). However, placing multiple small implants into the knee presents a greater surgical challenge than total knee arthroplasty, so it is not certain that the natural knee mechanics can be maintained or restored. The goal of this study was to determine whether near-normal knee kinematics can be obtained with a robot-assisted multi-compartmental knee arthroplasty. Thirteen patients with 15 multi-compartmental knee arthroplasties using haptic robotic-assisted bone preparation were involved in this study. Nine subjects received a medial unicompartmental knee arthroplasty (UKA), three subjects received a medial UKA and patellofemoral (PF) arthroplasty, and three subjects received medial and lateral bi-unicondylar arthroplasty. Knee motions were recorded using video-fluoroscopy an average of 13 months (6-29 months) after surgery during stair and kneeling activities. The three-dimensional position and orientation of the implant components were determined using model-image registration techniques. Knee kinematics during maximum flexion kneeling showed femoral external rotation and posterior lateral condylar translation. All knees showed femoral external rotation and posterior condylar translation with flexion during the step activity. Knees with medial UKA and PF arthroplasty showed the most femoral external rotation and posterior translation, and knees with bicondylar UKA showed the least. Knees with accurately placed uni- or bi-compartmental arthroplasty exhibited stable knee kinematics consistent with intact and functioning cruciate ligaments. The patterns of tibiofemoral motion were more similar to natural knees than commonly has been observed in knees with total knee

  12. Anticipation, teamwork and cognitive load: chasing efficiency during robot-assisted surgery.

    Science.gov (United States)

    Sexton, Kevin; Johnson, Amanda; Gotsch, Amanda; Hussein, Ahmed A; Cavuoto, Lora; Guru, Khurshid A

    2018-02-01

    Robot-assisted surgery (RAS) has changed the traditional operating room (OR), occupying more space with equipment and isolating console surgeons away from the patients and their team. We aimed to evaluate how anticipation of surgical steps and familiarity between team members impacted efficiency. We analysed recordings (video and audio) of 12 robot-assisted radical prostatectomies. Any requests between surgeon and the team members were documented and classified by personnel, equipment type, mode of communication, level of inconvenience in fulfilling the request and anticipation. Surgical team members completed questionnaires assessing team familiarity and cognitive load (National Aeronautics and Space Administration - Task Load Index). Predictors of team efficiency were assessed using Pearson correlation and stepwise linear regression. 1330 requests were documented, of which 413 (31%) were anticipated. Anticipation correlated negatively with operative time, resulting in overall 8% reduction of OR time. Team familiarity negatively correlated with inconveniences. Anticipation ratio, per cent of requests that were non-verbal and total request duration were significantly correlated with the console surgeons' cognitive load (r=0.77, p=0.006; r=0.63, p=0.04; and r=0.70, p=0.02, respectively). Anticipation and active engagement by the surgical team resulted in shorter operative time, and higher familiarity scores were associated with fewer inconveniences. Less anticipation and non-verbal requests were also associated with lower cognitive load for the console surgeon. Training efforts to increase anticipation and team familiarity can improve team efficiency during RAS. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects.

    Science.gov (United States)

    Mota Filho, Francisco Hidelbrando Alves; Sávio, Luis Felipe; Sakata, Rafael Eiji; Ivanovic, Renato Fidelis; da Silva, Marco Antonio Nunes; Maia, Ronaldo; Passerotti, Carlo

    2018-01-01

    Robot-Assisted Single Site Radical Nephrectomy (RASS-RN) has been reported by surgeons in Europe and United States (1-3). To our best knowledge this video presents the first RASS-RN with concomitant cholecystectomy performed in Latin America. A 66 year-old renal transplant male due to chronic renal failure presented with an incidental 1.3cm nodule in the upper pole of the right kidney. In addition, symptomatic gallbladder stones were detected. Patient was placed in modified flank position. Multichannel single port device was placed using Hassan's technique through a 3cm supra-umbilical incision. Standard radical nephrectomy and cholecystectomy were made using na 8.5mm camera, two 5mm robotic arms and an assistant 5mm access. Surgery time and estimated blood loss were 208 minutes and 100mL, respectively. Patient did well and was discharged within less than 48 hours, without complications. Pathology report showed benign renomedullary tumor of interstitial cells and chronic cholecystitis. Robotic technology improves ergonomics, gives better precision and enhances ability to approach complex surgeries. Robot-assisted Single Port aims to reduce the morbidity of multiple trocar placements while maintaining the advantages of robotic surgery (2). Limitations include the use of semi-rigid instruments providing less degree of motion and limited space leading to crash between instruments. On the other hand, it is possible to perform complex and concomitant surgeries with just one incision. RASS-RN seems to be safe and feasible option for selected cases. Studies should be performed to better understand the results using single port technique in Urology. Copyright® by the International Brazilian Journal of Urology.

  14. Robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects

    Directory of Open Access Journals (Sweden)

    Francisco Hidelbrando Alves Mota Filho

    Full Text Available ABSTRACT Introduction Robot-Assisted Single Site Radical Nephrectomy (RASS-RN has been reported by surgeons in Europe and United States (1–3. To our best knowledge this video presents the first RASS-RN with concomitant cholecystectomy performed in Latin America. Case A 66 year-old renal transplant male due to chronic renal failure presented with an incidental 1.3cm nodule in the upper pole of the right kidney. In addition, symptomatic gallbladder stones were detected. Results Patient was placed in modified flank position. Multichannel single port device was placed using Hassan's technique through a 3 cm supra-umbilical incision. Standard radical nephrectomy and cholecystectomy were made using an 8.5mm camera, two 5mm robotic arms and an assistant 5mm access. Surgery time and estimated blood loss were 208 minutes and 100mL, respectively. Patient did well and was discharged within less than 48 hours, without complications. Pathology report showed benign renomedullary tumor of interstitial cells and chronic cholecystitis. Discussion Robotic technology improves ergonomics, gives better precision and enhances ability to approach complex surgeries. Robot-assisted Single Port aims to reduce the morbidity of multiple trocar placements while maintaining the advantages of robotic surgery (2. Limitations include the use of semi-rigid instruments providing less degree of motion and limited space leading to crash between instruments. On the other hand, it is possible to perform complex and concomitant surgeries with just one incision. Conclusion RASS-RN seems to be safe and feasible option for selected cases. Studies should be performed to better understand the results using single port technique in Urology.

  15. Robot-assisted gait training in patients with Parkinson disease: a randomized controlled trial.

    Science.gov (United States)

    Picelli, Alessandro; Melotti, Camilla; Origano, Francesca; Waldner, Andreas; Fiaschi, Antonio; Santilli, Valter; Smania, Nicola

    2012-05-01

    . Gait impairment is a common cause of disability in Parkinson disease (PD). Electromechanical devices to assist stepping have been suggested as a potential intervention. . To evaluate whether a rehabilitation program of robot-assisted gait training (RAGT) is more effective than conventional physiotherapy to improve walking. . A total of 41 patients with PD were randomly assigned to 45-minute treatment sessions (12 in all), 3 days a week, for 4 consecutive weeks of either robotic stepper training (RST; n = 21) using the Gait Trainer or physiotherapy (PT; n = 20) with active joint mobilization and a modest amount of conventional gait training. Participants were evaluated before, immediately after, and 1 month after treatment. Primary outcomes were 10-m walking speed and distance walked in 6 minutes. . Baseline measures revealed no statistical differences between groups, but the PT group walked 0.12 m/s slower; 5 patients withdrew. A statistically significant improvement was found in favor of the RST group (walking speed 1.22 ± 0.19 m/s [P = .035]; distance 366.06 ± 78.54 m [P < .001]) compared with the PT group (0.98 ± 0.32 m/s; 280.11 ± 106.61 m). The RAGT mean speed increased by 0.13 m/s, which is probably not clinically important. Improvements were maintained 1 month later. . RAGT may improve aspects of walking ability in patients with PD. Future trials should compare robotic assistive training with treadmill or equal amounts of overground walking practice.

  16. Laparoscopic hand-assisted versus robotic-assisted laparoscopic sleeve gastrectomy: experience of 103 consecutive cases.

    Science.gov (United States)

    Kannan, Umashankkar; Ecker, Brett L; Choudhury, Rashikh; Dempsey, Daniel T; Williams, Noel N; Dumon, Kristoffel R

    2016-01-01

    Laparoscopic sleeve gastrectomy has become a stand-alone procedure in the treatment of morbid obesity. There are very few reports on the use of robotic approach in sleeve gastrectomy. The purpose of this retrospective study is to report our early experience of robotic-assisted laparoscopic sleeve gastrectomy (RALSG) using a proctored training model with comparison to an institutional cohort of patients who underwent laparoscopic hand-assisted sleeve gastrectomy (LASG). University hospital. The study included 108 patients who underwent sleeve gastrectomy either via the laparoscopic-assisted or robot-assisted approach during the study period. Of these 108 patients, 62 underwent LASG and 46 underwent RALSG. The console surgeon in the RALSG is a clinical year 4 (CY4) surgery resident. All CY4 surgery residents received targeted simulation training before their rotation. The console surgeon is proctored by the primary surgeon with assistance as needed by the second surgeon. The patients in the robotic and laparoscopic cohorts did not have a statistical difference in their demographic characteristics, preoperative co-morbidities, or complications. The mean operating time did not differ significantly between the 2 cohorts (121 min versus 110 min, P = .07). Patient follow-up in the LSG and RALSG were 91% and 90% at 3 months, 62% and 64% at 6 months, and 60% and 55% at 1 year, respectively. The mean percentage estimated weight loss (EWL%) at 3 months, 6 months, and 1 year was greater in the robotic group but not statistically significant (27 versus 22 at 3 mo [P = .05] and 39 versus 34 at 6 mo [P = .025], 57 versus 48 at 1 yr [P = .09]). There was no mortality in either group. Early results of our experience with RALSG indicate low perioperative complication rates and comparable weight loss with LASG. The concept of a stepwise education model needs further validation with larger studies. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc

  17. Operative technique and early experience for robotic-assisted laparoscopic nephroureterectomy (RALNU) using da Vinci Xi.

    Science.gov (United States)

    Darwiche, Fadi; Swain, Sanjaya; Kallingal, George; Punnen, Sanoj; Manoharan, Murugesan; Parekh, Dipen J; Gonzalgo, Mark L

    2015-01-01

    Robotic-assisted laparoscopic nephroureterectomy (RALNU) has been previously utilized for management of upper tract urothelial carcinoma. The da Vinci Xi surgical system was released in April of 2014. We describe our operative technique and early experience for RALNU using the da Vinci Xi system highlighting unique features of this surgical platform. A total of 10 patients with a diagnosis of upper tract urothelial carcinoma underwent RALNU using the da Vinci Xi system between April and November of 2014. A novel, oblique "in line" robotic trocar configuration was utilized to access the upper abdomen (nephrectomy portion) and pelvis (bladder cuff excision) without undocking. The port hopping feature of da Vinci Xi was utilized to facilitate optimal, multi-quadrant visualization during RALNU. Robotic-assisted laparoscopic nephroureterectomy was successfully completed without open conversion in all 10 patients. Mean operative time was 184 min (range 140-300 min), mean estimated blood loss was 121 cc (range 60-300 cc), and mean hospital stay was 2.4 days. Final pathology demonstrated high grade urothelial carcinoma in all patients. Surgical margins were negative in all patients. No intra-operative complications were encountered. One patient developed a pulmonary embolus after being discharged. No patients required a blood transfusion. Mean patient follow-up was 130 days (range 15-210 days). The use of da Vinci Xi with a novel, oblique "in line" port configuration and camera port hopping technique allows for an efficient and reproducible method for RALNU without the need for repositioning the patient or the robot during surgery.

  18. Intraoperative registered transrectal ultrasound guidance for robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Mohareri, Omid; Ischia, Joseph; Black, Peter C; Schneider, Caitlin; Lobo, Julio; Goldenberg, Larry; Salcudean, Septimiu E

    2015-01-01

    To provide unencumbered real-time ultrasound image guidance during robot-assisted laparoscopic radical prostatectomy, we developed a robotic transrectal ultrasound system that tracks the da Vinci® Surgical System instruments. We describe our initial clinical experience with this system. After an evaluation in a canine model, 20 patients were enrolled in the study. During each procedure the transrectal ultrasound transducer was manually positioned using a brachytherapy stabilizer to provide good imaging of the prostate. Then the transrectal ultrasound was registered to the da Vinci robot by a previously validated procedure. Finally, automatic rotation of the transrectal ultrasound was enabled such that the transrectal ultrasound imaging plane safely tracked the tip of the da Vinci instrument controlled by the surgeon, while real-time transrectal ultrasound images were relayed to the surgeon at the da Vinci console. Tracking was activated during all critical stages of the surgery. The transrectal ultrasound robot was easy to set up and use, adding 7 minutes (range 5 to 14) to the procedure. It did not require an assistant or additional control devices. Qualitative feedback was acquired from the surgeons, who found transrectal ultrasound useful in identifying the urethra while passing the dorsal venous complex suture, defining the prostate-bladder interface during bladder neck dissection, identifying the seminal vesicles and their location with respect to the rectal wall, and identifying the distal prostate boundary at the apex. Real-time, registered robotic transrectal ultrasound guidance with automatic instrument tracking during robot-assisted laparoscopic radical prostatectomy is feasible and potentially useful. The results justify further studies to establish whether the approach can improve procedure outcomes. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  19. Robot-assisted laparoscopic partial nephrectomy: Current review of the technique and literature

    Directory of Open Access Journals (Sweden)

    Singh Iqbal

    2009-01-01

    Full Text Available Aim: To visit the operative technique and to review the current published English literature on the technique, and outcomes following robot-assisted laparoscopic partial nephrectomy (RPN. Materials and Methods: We searched the published English literature and the PubMed (TM for published series of ′robotic partial nephrectomy′ (RPN using the keywords; robot, robot-assisted laparoscopic partial nephrectomy, laparoscopic partial nephrectomy, partial nephrectomy and laparoscopic surgery. Results: The search yielded 15 major selected series of ′robotic partial nephrectomy′; these were reviewed, tracked and analysed in order to determine the current status and role of RPN in the management of early renal neoplasm(s, as a minimally invasive surgical alternative to open partial nephrectomy. A review of the initial peri-operative outcome of the 350 cases of select series of RPN reported in published English literature revealed a mean operating time, warm ischemia time, estimated blood loss and hospital stay, of 191 minutes, 25 minutes, 162 ml and 2.95 days, respectively. The overall computed mean complication rate of RPN in the present select series was about 7.4%. Conclusions: RPN is a safe, feasible and effective minimally invasive surgical alternative to laparoscopic partial nephrectomy for early stage (T 1 renal neoplasm(s. It has acceptable initial renal functional outcomes without the increased risk of major complications in experienced hands. Prospective randomised, controlled, comparative clinical trials with laparoscopic partial nephrectomy (LPN are the need of the day. While the initial oncological outcomes of RPN appear to be favourable, long-term data is awaited.

  20. Outcomes of infants undergoing robot-assisted laparoscopic pyeloplasty compared to open repair.

    Science.gov (United States)

    Dangle, Pankaj P; Kearns, James; Anderson, Blake; Gundeti, Mohan S

    2013-12-01

    Robotic surgery has evolved from simple extirpative surgery to complex reconstructions even in infants. Data are lacking comparing surgical and direct costs to open approaches. We describe the feasibility, salient tips and outcomes of robot-assisted laparoscopic pyeloplasty compared to an open approach. We evaluated patients undergoing open pyeloplasty or robot-assisted laparoscopic pyeloplasty. Ten patients in each group met inclusion criteria. Mean patient age was 3.31 months in the open group and 7.3 months in the robotic group (p=0.02). Postoperative outcomes including length of stay (2.2 vs 2.1 days), estimated blood loss (6.5 vs 7.6 ml), days to regular diet (1 vs 1.1) and days to Foley catheter removal (1.3 vs 1.3) were similar between the open and robotic groups. Total operating time (199 vs 242 minutes) was significantly longer in the robotic group. Postoperative improvement in hydronephrosis was identical in both groups. Direct costs, excluding amortization, robotic cost, maintenance and depreciation, were $4,410 in the open group and $4,979 in the robotic group (p=0.10). In our preliminary experience robotic pyeloplasty in infants is feasible and safe. The immediate outcomes are similar to those of an open approach. The robotic technique in infants currently has the benefits of improved esthetic appearance, improved pain control and similar direct costs compared to the traditional open approach. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  1. Robotic-assisted versus laparoscopic colorectal surgery: a meta-analysis of four randomized controlled trials

    Science.gov (United States)

    2014-01-01

    Background Robotic-assisted laparoscopy is popularly performed for colorectal disease. The objective of this meta-analysis was to compare the safety and efficacy of robotic-assisted colorectal surgery (RCS) and laparoscopic colorectal surgery (LCS) for colorectal disease based on randomized controlled trial studies. Methods Literature searches of electronic databases (Pubmed, Web of Science, and Cochrane Library) were performed to identify randomized controlled trial studies that compared the clinical or oncologic outcomes of RCS and LCS. This meta-analysis was performed using the Review Manager (RevMan) software (version 5.2) that is provided by the Cochrane Collaboration. The data used were mean differences and odds ratios for continuous and dichotomous variables, respectively. Fixed-effects or random-effects models were adopted according to heterogeneity. Results Four randomized controlled trial studies were identified for this meta-analysis. In total, 110 patients underwent RCS, and 116 patients underwent LCS. The results revealed that estimated blood losses (EBLs), conversion rates and times to the recovery of bowel function were significantly reduced following RCS compared with LCS. There were no significant differences in complication rates, lengths of hospital stays, proximal margins, distal margins or harvested lymph nodes between the two techniques. Conclusions RCS is a promising technique and is a safe and effective alternative to LCS for colorectal surgery. The advantages of RCS include reduced EBLs, lower conversion rates and shorter times to the recovery of bowel function. Further studies are required to define the financial effects of RCS and the effects of RCS on long-term oncologic outcomes. PMID:24767102

  2. Comparison of fiber delivered CO2 laser and electrocautery in transoral robot assisted tongue base surgery.

    Science.gov (United States)

    Karaman, Murat; Gün, Taylan; Temelkuran, Burak; Aynacı, Engin; Kaya, Cem; Tekin, Ahmet Mahmut

    2017-05-01

    To compare intra-operative and post-operative effectiveness of fiber delivered CO 2 laser to monopolar electrocautery in robot assisted tongue base surgery. Prospective non-randomized clinical study. Twenty moderate to severe obstructive sleep apnea (OSA) patients, non-compliant with Continuous Positive Airway Pressure (CPAP), underwent Transoral Robotic Surgery (TORS) using the Da Vinci surgical robot in our University Hospital. OSA was treated with monopolar electrocautery in 10 patients, and with flexible CO 2 laser fiber in another 10 patients. The following parameters in the two sets are analyzed: Intraoperative bleeding that required cauterization, robot operating time, need for tracheotomy, postoperative self-limiting bleeding, length of hospitalization, duration until start of oral intake, pre-operative and post-operative minimum arterial oxygen saturation, pre-operative and post-operative Epworth Sleepiness Scale score, postoperative airway complication and postoperative pain. Mean follow-up was 12 months. None of the patients required tracheotomy and there were no intraoperative complications related to the use of the robot or the CO 2 laser. The use of CO 2 laser in TORS-assisted tongue base surgery resulted in less intraoperative bleeding that required cauterization, shorter robot operating time, shorter length of hospitalization, shorter duration until start of oral intake and less postoperative pain, when compared to electrocautery. Postoperative apnea-hypopnea index scores showed better efficacy of CO 2 laser than electrocautery. Comparison of postoperative airway complication rates and Epworth sleepiness scale scores were found to be statistically insignificant between the two groups. The use of CO 2 laser in robot assisted tongue base surgery has various intraoperative and post-operative advantages when compared to monopolar electrocautery.

  3. Evaluation of robotic-assisted platysmaplasty procedures in a cadaveric model using the da Vinci Surgical System.

    Science.gov (United States)

    Taghizadeh, Farhan; Reiley, Carol; Mohr, Catherine; Paul, Malcolm

    2014-03-01

    We are evaluating the technical feasibility of robotic-assisted laparoscopic vertical-intermediate platysmaplasty in conjunction with an open rhytidectomy. In a cadaveric study, the da Vinci Surgical System was used to access certain angles in the lower neck that are difficult for traditional short incision, short flap procedures. Ergonomics, approach, and technical challenges were noted. To date, there are no published reports of robotic-assisted neck lifts, motivating us to assess its potential in this field of plastic surgery. Standard open technique short flap rhytidectomies with concurrent experimental robotic-assisted platysmaplasties (neck lifts) were performed on six cadavers with the da Vinci Si Surgical System(®) (Intuitive Surgical, Sunnyvale, CA, USA). The surgical procedures were performed on a diverse cadaver population from June 2011 to January 2012. The procedures included (1) submental incision and laser-assisted liposuction, (2) open rhytidectomy, and (3) robotic-assisted platysmaplasty using knot-free sutures. A variety of sutures and fat extraction techniques, coupled with 0° and 30° three-dimensional endoscopes, were utilized to optimize visualization of the platysma. An unaltered da Vinci Si Surgical System with currently available instruments was easily adaptable to neck lift surgery. Mid-neck platysma exposure was excellent, tissue handling was delicate and precise, and suturing was easily performed. Robotic-assisted surgery has the potential to improve outcomes in neck lifts by offering the ability to manipulate instruments with increased freedom of movement, scaled motion, tremor reduction, and stereoscopic three-dimensional visualization in the deep neck. Future clinical studies on live human patients can better assess subject and surgeon benefits arising from the use of the da Vinci system for neck lifts. Evidence obtained from multiple time series with or without the intervention, such as case studies. Dramatic results in

  4. Perioperative analgesic requirements in severely obese adolescents and young adults undergoing laparoscopic versus robotic-assisted gastric sleeve resection

    Directory of Open Access Journals (Sweden)

    Anita Joselyn

    2015-01-01

    Full Text Available Purpose: One of the major advantages for patients undergoing minimally invasive surgery as compared to an open surgical procedure is the improved recovery profile and decreased opioid requirements in the perioperative period. There are no definitive studies comparing the analgesic requirements in patients undergoing two different types of minimally invasive procedure. This study retrospectively compares the perioperative analgesic requirements in severely obese adolescents and young adults undergoing laparoscopic versus robotic-assisted, laparoscopic gastric sleeve resection. Materials and Methods: With Institutional Review Board approval, the medication administration records of all severely obese patients who underwent gastric sleeve resection were retrospectively reviewed. Intra-operative analgesic and adjuvant medications administered, postoperative analgesic requirements, and visual analog pain scores were compared between those undergoing a laparoscopic procedure versus a robotic-assisted procedure. Results: This study cohort included a total of 28 patients who underwent gastric sleeve resection surgery with 14 patients in the laparoscopic group and 14 patients in the robotic-assisted group. Intra-operative adjuvant administration of both intravenous acetaminophen and ketorolac was similar in both groups. Patients in the robotic-assisted group required significantly less opioid during the intra-operative period as compared to patients in the laparoscopic group (0.15 ± 0.08 mg/kg vs. 0.19 ± 0.06 mg/kg morphine, P = 0.024. Cumulative opioid requirements for the first 72 postoperative h were similar in both the groups (0.64 ± 0.25 vs. 0.68 ± 0.27 mg/kg morphine, P = NS. No difference was noted in the postoperative pain scores. Conclusion: Although intraoperative opioid administration was lower in the robotic-assisted group, the postoperative opioid requirements, and the postoperative pain scores were similar in both groups.

  5. Robot-assisted laparoscopic versus open partial nephrectomy in patients with chronic kidney disease: A propensity score-matched comparative analysis of surgical outcomes.

    Science.gov (United States)

    Takagi, Toshio; Kondo, Tsunenori; Tachibana, Hidekazu; Iizuka, Junpei; Omae, Kenji; Kobayashi, Hirohito; Yoshida, Kazuhiko; Tanabe, Kazunari

    2017-07-01

    To compare surgical outcomes between robot-assisted laparoscopic partial nephrectomy and open partial nephrectomy in patients with chronic kidney disease. Of 550 patients who underwent partial nephrectomy between 2012 and 2015, 163 patients with T1-2 renal tumors who had an estimated glomerular filtration rate between 30 and 60 mL/min/1.73 m 2 , and underwent robot-assisted laparoscopic partial nephrectomy or open partial nephrectomy were retrospectively analyzed. To minimize selection bias between the two surgical methods, patient variables were adjusted by 1:1 propensity score matching. The present study included 75 patients undergoing robot-assisted laparoscopic partial nephrectomy and 88 undergoing open partial nephrectomy. After propensity score matching, 40 patients were included in each operative group. The mean preoperative estimated glomerular filtration rate was 49 mL/min/1.73 m 2 . The mean ischemia time was 21 min in robot-assisted laparoscopic partial nephrectomy (warm ischemia) and 35 min in open partial nephrectomy (cold ischemia). Preservation of the estimated glomerular filtration rate 3-6 months postoperatively was not significantly different between robot-assisted laparoscopic partial nephrectomy and open partial nephrectomy (92% vs 91%, P = 0.9348). Estimated blood loss was significantly lower in the robot-assisted laparoscopic partial nephrectomy group than in the open partial nephrectomy group (104 vs 185 mL, P = 0.0025). The postoperative length of hospital stay was shorter in the robot-assisted laparoscopic partial nephrectomy group than in the open partial nephrectomy group (P negative surgical margin status were not significantly different between the two groups. In our experience, robot-assisted laparoscopic partial nephrectomy and open partial nephrectomy provide similar outcomes in terms of functional preservation and perioperative complications among patients with chronic kidney disease. However, a lower estimated blood loss and

  6. Robot-assisted posterior retroperitoneoscopic adrenalectomy using single-port access: technical feasibility and preliminary results.

    Science.gov (United States)

    Park, Jae Hyun; Kim, Soo Young; Lee, Cho-Rok; Park, Seulkee; Jeong, Jun Soo; Kang, Sang-Wook; Jeong, Jong Ju; Nam, Kee-Hyun; Chung, Woong Youn; Park, Cheong Soo

    2013-08-01

    Posterior retroperitoneoscopic adrenalectomy (PRA) has several benefits compared with transperitoneal adrenalectomy in that it is safe and has a short learning curve. In addition, it provides direct short access to the target organ, prevents irritation to the intraperitoneal space, and does not require retraction of adjacent organs.1 (-) 3 We have performed several cases of robot-assisted PRA using single-port access for small adrenal tumors. This multimedia article introduces the detailed methods and preliminary results of this procedure. Five patients underwent single-port robot-assisted PRA between March 2010 and June 2011 at our institution. During the procedure, patients were placed in a prone jackknife position with their hip joints bent at a right angle (Fig. 1). A 3 cm transverse skin incision was made just below the lowest tip of the 12th rib (Fig. 2), and the Glove port (Nelis, Kyung-gi, Korea) was placed through the skin incision while maintaining pneumoretroperitoneum (Fig. 3). CO2 was then insufflated to a pressure of 18 mm Hg to create an adequate working space. A 10 mm robotic camera with a 30-degree up view was placed at the center of the incision through the most cephalic portion of the Glove port. A Maryland dissector or Prograsp forceps (Intuitive Surgical, Inc., Sunnyvale, CA) was placed on the medial side of the incision, and Harmonic curved shears (Intuitive Surgical) were placed on the lateral side of the incision (Fig. 4). Using the Maryland dissector and the harmonic curved shears, the Gerota fascia is opened, perinephric fat is dissected, and the kidney upper pole is mobilized to expose the adrenal gland (Fig. 5). Gland dissection starts with lower margin detachment from the upper kidney pole in a lateral to medial direction (Fig. 6). After dissecting the adrenal gland from surrounding adipose tissue and medial isolation of the adrenal central vein, the vessel is ligated with a 5 mm hemolock clip (Fig. 7). Patient

  7. Decreased Time to Return to Work Using Robotic-Assisted Unicompartmental Knee Arthroplasty Compared to Conventional Techniques.

    Science.gov (United States)

    Jinnah, Alexander H; Augart, Marco A; Lara, Daniel L; Jinnah, Riyaz H; Poehling, Gary G; Gwam, Chukwuweike U; Plate, Johannes F

    2018-06-01

    Unicompartmental knee arthroplasty (UKA) is a commonly used procedure for patients suffering from debilitating unicompartmental knee arthritis. For UKA recipients, robotic-assisted surgery has served as an aid in improving surgical accuracy and precision. While studies exist detailing outcomes of robotic UKA, to our knowledge, there are no studies assessing time to return to work using robotic-assisted UKA. Thus, the purpose of this study was to prospectively assess the time to return to work and to achieve the level of work activity following robotic-assisted UKA to create recommendations for patients preoperatively. We hypothesized that the return to work time would be shorter for robotic-assisted UKAs compared with TKAs and manual UKAs, due to more accurate ligament balancing and precise implementation of the operative plan. Thirty consecutive patients scheduled to undergo a robotic-assisted UKA at an academic teaching hospital were prospectively enrolled in the study. Inclusion criteria included employment at the time of surgery, with the intent on returning to the same occupation following surgery and having end-stage knee degenerative joint disease (DJD) limited to the medial compartment. Patients were contacted via email, letter, or phone at two, four, six, and 12 weeks following surgery until they returned to work. The Baecke physical activity questionnaire (BQ) was administered to assess patients' level of activity at work pre- and postoperatively. Statistical analysis was performed using SAS Enterprise Guide (SAS Institute Inc., Cary, North Carolina) and Excel® (Microsoft Corporation, Redmond, Washington). Descriptive statistics were calculated to assess the demographics of the patient population. Boxplots were generated using an Excel® spreadsheet to visualize the BQ scores and a two-tailed t-test was used to assess for differences between pre- and postoperative scores with alpha 0.05. The mean time to return to work was 6.4 weeks (SD=3.4, range 2

  8. Robot-assisted Partial Nephrectomy: 5-yr Oncological Outcomes at a Single European Tertiary Cancer Center.

    Science.gov (United States)

    Vartolomei, Mihai Dorin; Matei, Deliu Victor; Renne, Giuseppe; Tringali, Valeria Maria; Crisan, Nicolae; Musi, Gennaro; Mistretta, Francesco Alessandro; Russo, Andrea; Cozzi, Gabriele; Cordima, Giovani; Luzzago, Stefano; Cioffi, Antonio; Di Trapani, Ettore; Catellani, Michele; Delor, Maurizio; Bottero, Danilo; Imbimbo, Ciro; Mirone, Vincenzo; Ferro, Matteo; de Cobelli, Ottavio

    2017-10-27

    Nowadays, there is a debate about which surgical treatment should be best for clinical T1 renal tumors. If the oncological outcomes are considered, there are many open and laparoscopic series published. As far as robotic series are concerned, only a few of them report 5-yr oncological outcomes. The aim of this study was to analyze robot-assisted partial nephrectomy (RAPN) midterm oncological outcomes achieved in a tertiary robotic reference center. Between April 2009 and September 2013, 123 consecutive patients with clinical T1-stage renal masses underwent RAPN in our tertiary cancer center. Inclusion criteria were as follows: pathologically confirmed renal cell carcinomas (RCCs) and follow-up for >12 mo. Eighteen patients were excluded due to follow-up of <12 mo and 15 due to benign final pathology. Median follow-up was 59 mo (interquartile range 44-73 mo). Patients were followed according to guideline recommendations and institutional protocol. Outcomes were measured by time to disease progression, overall survival, or time to cancer-specific death. Kaplan-Meier method was used to estimate survival; log-rank tests were applied for pair-wise comparison of survival. From the 90 patients included, 66 (73.3%) had T1a, 12 (13.3%) T1b, three (3.3%) T2a, and nine (10%) T3a tumors. Predominant histological type was clear cell carcinoma: 67 (74.5%). Fuhrmann grade 1 and 2 was found in 73.3% of all malignant tumors. Two patients (2.2%) had positive surgical margins, and complication rate was 17.8%. Relapse rate was 7.7%, including two cases (2.2%) of local recurrences and five (5.5%) distant metastasis. Five-year disease-free survival was 90.9%, 5-yr cancer-specific survival was 97.5%, and 5-yr overall survival was 95.1%. Midterm oncological outcomes after RAPN for localized RCCs (predominantly T1a tumors of low anatomic complexity) were shown to be good, adding significant evidence to support the oncological efficacy and safety of RAPN for the treatment of this type of

  9. Robot-assisted Salvage Lymph Node Dissection for Clinically Recurrent Prostate Cancer.

    Science.gov (United States)

    Montorsi, Francesco; Gandaglia, Giorgio; Fossati, Nicola; Suardi, Nazareno; Pultrone, Cristian; De Groote, Ruben; Dovey, Zach; Umari, Paolo; Gallina, Andrea; Briganti, Alberto; Mottrie, Alexandre

    2017-09-01

    Salvage lymph node dissection has been described as a feasible treatment for the management of prostate cancer patients with nodal recurrence after primary treatment. To report perioperative, pathologic, and oncologic outcomes of robot-assisted salvage nodal dissection (RASND) in patients with nodal recurrence after radical prostatectomy (RP). We retrospectively evaluated 16 patients affected by nodal recurrence following RP documented by positive positron emission tomography/computed tomography scan. Surgery was performed using DaVinci Si and Xi systems. A pelvic nodal dissection that included lymphatic stations overlying the external, internal, and common iliac vessels, the obturator fossa, and the presacral nodes was performed. In 13 (81.3%) patients a retroperitoneal lymph node dissection that included all nodal tissue located between the aortic bifurcation and the renal vessels was performed. Perioperative outcomes consisted of operative time, blood loss, length of hospital stay, and complications occurred within 30 d after surgery. Biochemical response (BR) was defined as a prostate-specific antigen level <0.2 ng/ml at 40 d after RASND. Median operative time, blood loss, and length of hospital stay were 210min, 250ml, and 3.5 d. The median number of nodes removed was 16.5. Positive lymph nodes were detected in 11 (68.8%) patients. Overall, four (25.0%) and five (31.2%) patients experienced intraoperative and postoperative complications, respectively. Overall, one (6.3%) and four (25.0%) patients had Clavien I and II complications within 30 d after RASND, respectively. Overall, five (33.3%) patients experienced BR after surgery. Our study is limited by the small cohort of patients evaluated and by the follow-up duration. RASND represents a feasible procedure in patients with nodal recurrence after RP and provides acceptable short-term oncologic outcomes, where one out of three patients experience BR immediately after surgery. Long-term data are needed to

  10. Ankle voluntary movement enhancement following robotic-assisted locomotor training in spinal cord injury.

    Science.gov (United States)

    Varoqui, Deborah; Niu, Xun; Mirbagheri, Mehdi M

    2014-03-31

    In incomplete spinal cord injury (iSCI), sensorimotor impairments result in severe limitations to ambulation. To improve walking capacity, physical therapies using robotic-assisted locomotor devices, such as the Lokomat, have been developed. Following locomotor training, an improvement in gait capabilities-characterized by increases in the over-ground walking speed and endurance-is generally observed in patients. To better understand the mechanisms underlying these improvements, we studied the effects of Lokomat training on impaired ankle voluntary movement, known to be an important limiting factor in gait for iSCI patients. Fifteen chronic iSCI subjects performed twelve 1-hour sessions of Lokomat training over the course of a month. The voluntary movement was qualified by measuring active range of motion, maximal velocity peak and trajectory smoothness for the spastic ankle during a movement from full plantar-flexion (PF) to full dorsi-flexion (DF) at the patient's maximum speed. Dorsi- and plantar-flexor muscle strength was quantified by isometric maximal voluntary contraction (MVC). Clinical assessments were also performed using the Timed Up and Go (TUG), the 10-meter walk (10MWT) and the 6-minute walk (6MWT) tests. All evaluations were performed both before and after the training and were compared to a control group of fifteen iSCI patients. After the Lokomat training, the active range of motion, the maximal velocity, and the movement smoothness were significantly improved in the voluntary movement. Patients also exhibited an improvement in the MVC for their ankle dorsi- and plantar-flexor muscles. In terms of functional activity, we observed an enhancement in the mobility (TUG) and the over-ground gait velocity (10MWT) with training. Correlation tests indicated a significant relationship between ankle voluntary movement performance and the walking clinical assessments. The improvements of the kinematic and kinetic parameters of the ankle voluntary movement

  11. Pathological confirmation of nerve-sparing types performed during robot-assisted radical prostatectomy (RARP).

    Science.gov (United States)

    Ko, Woo Jin; Hruby, Gregory W; Turk, Andrew T; Landman, Jaime; Badani, Ketan K

    2013-03-01

    WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: Incremental nerve-sparing techniques (NSTs) improve postoperative erectile function after robot-assisted radical prostatectomy (RARP). However, there are no studies to date that histologically confirm the surgeon intended NST. Thus, in the present study, we histologically confirmed that the surgeon performed the nerve preservation as his intended NSTs during RARP. Also, we found that there was more variability in fascia width outcome on the left side compared with the right. Therefore, when performing nerve preservation on the surgeon's non-dominant side, we need to pay more close attention. To confirm that the surgeon achieved true intended histological nerve sparing during robot-assisted radical prostatectomy (RARP) by studying RP specimens. To aid the novice robotic surgeon to develop the skills of RARP. Between June 2008 and May 2009, 122 consecutive patients underwent RARP by a single surgeon (K.K.B.). The degree of nerve sparing (wide resection [WR], interfascial nerve sparing [ITE-NS], intrafascial nerve sparing [ITR-NS]) on both sides was recorded. The posterior sectors of RP specimens from distal, mid, and proximal parts were evaluated. Fascia width (FW) of each position in RP specimens were compared across nerve-sparing types (NSTs). FW was recorded at 15 ° intervals (3-9 o'clock position), measured as the distance between the outermost prostate gland and surgical margin. The slides were reviewed by an experienced uropathologist who was 'blinded' to the NST. In all, 93 men were included. The overall mean (sd) FW was the greatest in the order of WR, ITE-NS, and ITR-NS, at 2.42 (1.62), 1.71 (1.40) and 1.16 (1.08) mm, respectively (P ITE-NS, bilateral ITE-NS, ITE-NS/WR, and bilateral WR, respectively. To further validate and confirm these preliminary findings, additional studies involving multicentre cohorts would be required. The surgeon intended dissection and FW correlate, with ITR

  12. Development of a fixation device for robot assisted fracture reduction of femoral shaft fractures: a biomechanical study.

    Science.gov (United States)

    Weber-Spickschen, T S; Oszwald, M; Westphal, R; Krettek, C; Wahl, F; Gosling, T

    2010-01-01

    Robot assisted fracture reduction of femoral shaft fractures provides precise alignment while reducing the amount of intraoperative imaging. The connection between the robot and the fracture fragment should allow conventional intramedullary nailing, be minimally invasive and provide interim fracture stability. In our study we tested three different reduction tools: a conventional External Fixator, a Reposition-Plate and a Three-Point-Device with two variations (a 40 degrees and a 90 degrees version). We measured relative movements between the tools and the bone fragments in all translation and rotation planes. The Three-Point-Device 90 degrees showed the smallest average relative displacement and was the only device able to withstand the maximum applied load of 70 Nm without failure of any bone fragment. The Three-Point-Device 90 degrees complies with all the stipulated requirements and is a suitable interface for robot assisted fracture reduction of femoral shaft fractures.

  13. Development of a teaching tool for women with a gynecologic malignancy undergoing minimally invasive robotic-assisted surgery.

    Science.gov (United States)

    Castiglia, Luisa Luciani; Drummond, Nancy; Purden, Margaret A

    2011-08-01

    Women undergoing minimally invasive robotic-assisted surgery for a gynecologic malignancy have many questions and concerns related to the cancer diagnosis and surgery. The provision of information enhances coping with such illness-related challenges. A lack of print materials for these patients prompted the creation of a written teaching tool to improve informational support. A booklet was developed using guidelines for the design of effective patient education materials, including an iterative process of collaboration with healthcare providers and women who had undergone robotic-assisted surgery, as well as attention to readability. The 52-page booklet covers the trajectory of the woman's experience and includes the physical, psychosocial, and sexual aspects of recovery.

  14. The "halo effect" in Korea: change in practice patterns since the introduction of robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Sung, Ee-Rah; Jeong, Wooju; Park, Sung Yul; Ham, Won Sik; Choi, Young Deuk; Hong, Sung Joon; Rha, Koon Ho

    2009-03-01

    Acquisition of the da Vinci surgical system (Intuitive Surgical, Mountain View, USA) has enabled robot-assisted surgery to become an acceptable alternative to open radical prostatectomy (ORP). Implementation of robotics at a single institution in Korea induced a gradual increase in the number of performances of robot-assisted laparoscopic radical prostatectomy (RALP) to surgically treat localized prostate cancer. We analyzed the impact of robotic instrumentation on practice patterns among urologists and explain the change in value in ORP and RALP-the standard treatment and the new approach or innovation of robotic technology. The overall number of prostatectomies has increased over time because the number of RALPs has grown drastically whereas the number of OPRs did not decrease during the period of evaluation. Our experience emphasizes the potential of RALP to become the gold standard in the treatment of localized prostate cancer in various parts of the world.

  15. No differences in short-term morbidity and mortality after robot-assisted laparoscopic versus laparoscopic resection for colonic cancer

    DEFF Research Database (Denmark)

    Helvind, Neel Maria; Eriksen, Jens Ravn; Mogensen, Anders Skibsted

    2013-01-01

    BACKGROUND: Robot-assisted laparoscopy has been reported to be a safe and feasible alternative to traditional laparoscopy. The aim of this study was to compare short-term results in patients with colonic cancer who underwent robot-assisted laparoscopic colonic resection (RC) or laparoscopic colonic...... journals. Biochemical markers [C-reactive protein (CRP), hemoglobin, white blood cell count, and thrombocyte count] were recorded before surgery and for the first 3 days after surgery. RESULTS: A total of 101 patients underwent RC and 162 patients underwent LC. There were no significant differences...... in the rate of conversion to open surgery, number of permanent enterostomies, number of intraoperative complications, level of postoperative cellular stress response, number of postoperative complications, length of postoperative hospital stay, or 30-day mortality between the two groups...

  16. Robotic assisted versus pure laparoscopic surgery of the adrenal glands: a case-control study comparing surgical techniques.

    Science.gov (United States)

    Morelli, Luca; Tartaglia, Dario; Bronzoni, Jessica; Palmeri, Matteo; Guadagni, Simone; Di Franco, Gregorio; Gennai, Andrea; Bianchini, Matteo; Bastiani, Luca; Moglia, Andrea; Ferrari, Vincenzo; Fommei, Enza; Pietrabissa, Andrea; Di Candio, Giulio; Mosca, Franco

    2016-11-01

    The role of the da Vinci Robotic System ® in adrenal gland surgery is not yet well defined. The goal of this study was to compare robotic-assisted surgery with pure laparoscopic surgery in a single center. One hundred and 16 patients underwent minimally invasive adrenalectomies in our department between June 1994 and December 2014, 41 of whom were treated with a robotic-assisted approach (robotic adrenalectomy, RA). Patients who underwent RA were matched according to BMI, age, gender, and nodule dimensions, and compared with 41 patients who had undergone laparoscopic adrenalectomies (LA). Statistical analysis was performed using the Student's t test for independent samples, and the relationship between the operative time and other covariates were evaluated with a multivariable linear regression model. P surgery (p surgery.

  17. Robot-assisted therapy for improving social interactions and activity participation among institutionalized older adults: a pilot study.

    Science.gov (United States)

    Sung, Huei-Chuan; Chang, Shu-Min; Chin, Mau-Yu; Lee, Wen-Li

    2015-03-01

    Animal-assisted therapy is gaining popularity as part of therapeutic activities for older adults in many long-term care facilities. However, concerns about dog bites, allergic responses to pets, disease, and insufficient available resources to care for a real pet have led to many residential care facilities to ban this therapy. There are situations where a substitute artificial companion, such as robotic pet, may serve as a better alternative. This pilot study used a one-group pre- and posttest design to evaluate the effect of a robot-assisted therapy for older adults. Sixteen eligible participants participated in the study and received a group robot-assisted therapy using a seal-like robot pet for 30 minutes twice a week for 4 weeks. All participants received assessments of their communication and interaction skills using the Assessment of Communication and Interaction Skills (ACIS-C) and activity participation using the Activity Participation Scale at baseline and at week 4. A total of 12 participants completed the study. Wilcoxon signed rank test showed that participants' communication and interaction skills (z = -2.94, P = 0.003) and activity participation (z = -2.66, P = 0.008) were significantly improved after receiving 4-week robot-assisted therapy. By interacting with a robot pet, such as Paro, the communication, interaction skills, and activity participation of the older adults can be improved. The robot-assisted therapy can be provided as a routine activity program and has the potential to improve social health of older adults in residential care facilities. Copyright © 2014 Wiley Publishing Asia Pty Ltd.

  18. Stratified analysis of 800 Asian patients after robot-assisted radical prostatectomy with a median 64 months of follow up.

    Science.gov (United States)

    Abdel Raheem, Ali; Kim, Dae Keun; Santok, Glen Denmer; Alabdulaali, Ibrahim; Chung, Byung Ha; Choi, Young Deuk; Rha, Koon Ho

    2016-09-01

    To report the 5-year oncological outcomes of robot-assisted radical prostatectomy from the largest series ever reported from Asia. A retrospective analysis of 800 Asian patients who were treated with robot-assisted radical prostatectomy from July 2005 to May 2010 in the Department of Urology and Urological Science Institute, Yonsei University College of Medicine, Seoul, Korea was carried out. The primary end-point was to evaluate the biochemical recurrence. The secondary end-point was to show the biochemical recurrence-free survival, metastasis-free survival and cancer-specific survival. A total of 197 (24.65%), 218 (27.3%), and 385 (48.1%) patients were classified as low-, intermediate- and high-risk patients according to the D'Amico risk stratification risk criteria, respectively. The median follow-up period was 64 months (interquartile range 28-71 months). The overall incidence of positive surgical margin was 36.6%. There was biochemical recurrence in 183 patients (22.9%), 38 patients (4.8%) developed distant metastasis and 24 patients (3%) died from prostate cancer. Actuarial biochemical recurrence-free survival, metastasis-free survival, and cancer-specific survival rates at 5 years were 76.4%, 94.6% and 96.7%, respectively. Positive lymph node was associated with lower 5-year biochemical recurrence-free survival (9.1%), cancer-specific survival (75.7%) and metastasis-free survival (61.9%) rates (P < 0.001). On multivariable analysis, among all the predictors, positive lymph node was the strongest predictor of biochemical recurrence, cancer-specific survival and metastasis-free survival (P < 0.001). Herein we report the largest robot-assisted radical prostatectomy series from Asia. Robot-assisted radical prostatectomy is confirmed to be an oncologically safe procedure that is able to provide effective 5-year cancer control, even in patients with high-risk disease. © 2016 The Japanese Urological Association.

  19. Recent trends in robot-assisted therapy environments to improve real-life functional performance after stroke

    OpenAIRE

    Johnson, Michelle J

    2006-01-01

    Abstract Upper and lower limb robotic tools for neuro-rehabilitation are effective in reducing motor impairment but they are limited in their ability to improve real world function. There is a need to improve functional outcomes after robot-assisted therapy. Improvements in the effectiveness of these environments may be achieved by incorporating into their design and control strategies important elements key to inducing motor learning and cerebral plasticity such as mass-practice, feedback, t...

  20. Reduction of freezing of gait in Parkinson's disease by repetitive robot-assisted treadmill training: a pilot study

    Directory of Open Access Journals (Sweden)

    Friedman Joseph H

    2010-10-01

    Full Text Available Abstract Background Parkinson's disease is a chronic, neurodegenerative disease characterized by gait abnormalities. Freezing of gait (FOG, an episodic inability to generate effective stepping, is reported as one of the most disabling and distressing parkinsonian symptoms. While there are no specific therapies to treat FOG, some external physical cues may alleviate these types of motor disruptions. The purpose of this study was to examine the potential effect of continuous physical cueing using robot-assisted sensorimotor gait training on reducing FOG episodes and improving gait. Methods Four individuals with Parkinson's disease and FOG symptoms received ten 30-minute sessions of robot-assisted gait training (Lokomat to facilitate repetitive, rhythmic, and alternating bilateral lower extremity movements. Outcomes included the FOG-Questionnaire, a clinician-rated video FOG score, spatiotemporal measures of gait, and the Parkinson's Disease Questionnaire-39 quality of life measure. Results All participants showed a reduction in FOG both by self-report and clinician-rated scoring upon completion of training. Improvements were also observed in gait velocity, stride length, rhythmicity, and coordination. Conclusions This pilot study suggests that robot-assisted gait training may be a feasible and effective method of reducing FOG and improving gait. Videotaped scoring of FOG has the potential advantage of providing additional data to complement FOG self-report.

  1. Predicting Functional Recovery in Chronic Stroke Rehabilitation Using Event-Related Desynchronization-Synchronization during Robot-Assisted Movement

    Directory of Open Access Journals (Sweden)

    Marco Caimmi

    2016-01-01

    Full Text Available Although rehabilitation robotics seems to be a promising therapy in the rehabilitation of the upper limb in stroke patients, consensus is still lacking on its additive effects. Therefore, there is a need for determining the possible success of robotic interventions on selected patients, which in turn determine the necessity for new investigating instruments supporting the treatment decision-making process and customization. The objective of the work presented in this preliminary study was to verify that fully robot assistance would not affect the physiological oscillatory cortical activity related to a functional movement in healthy subjects. Further, the clinical results following the robotic treatment of a chronic stroke patient, who positively reacted to the robotic intervention, were analyzed and discussed. First results show that there is no difference in EEG activation pattern between assisted and no-assisted movement in healthy subjects. Even more importantly, the patient’s pretreatment EEG activation pattern in no-assisted movement was completely altered, while it recovered to a quasi-physiological one in robot-assisted movement. The functional improvement following treatment was large. Using pretreatment EEG recording during robot-assisted movement might be a valid approach to assess the potential ability of the patient for recovering.

  2. Predicting Functional Recovery in Chronic Stroke Rehabilitation Using Event-Related Desynchronization-Synchronization during Robot-Assisted Movement

    Science.gov (United States)

    Gramigna, Cristina; Franceschetti, Silvana

    2016-01-01

    Although rehabilitation robotics seems to be a promising therapy in the rehabilitation of the upper limb in stroke patients, consensus is still lacking on its additive effects. Therefore, there is a need for determining the possible success of robotic interventions on selected patients, which in turn determine the necessity for new investigating instruments supporting the treatment decision-making process and customization. The objective of the work presented in this preliminary study was to verify that fully robot assistance would not affect the physiological oscillatory cortical activity related to a functional movement in healthy subjects. Further, the clinical results following the robotic treatment of a chronic stroke patient, who positively reacted to the robotic intervention, were analyzed and discussed. First results show that there is no difference in EEG activation pattern between assisted and no-assisted movement in healthy subjects. Even more importantly, the patient's pretreatment EEG activation pattern in no-assisted movement was completely altered, while it recovered to a quasi-physiological one in robot-assisted movement. The functional improvement following treatment was large. Using pretreatment EEG recording during robot-assisted movement might be a valid approach to assess the potential ability of the patient for recovering. PMID:27057546

  3. Hand Passive Mobilization Performed with Robotic Assistance: Acute Effects on Upper Limb Perfusion and Spasticity in Stroke Survivors

    Directory of Open Access Journals (Sweden)

    Massimiliano Gobbo

    2017-01-01

    Full Text Available This single arm pre-post study aimed at evaluating the acute effects induced by a single session of robot-assisted passive hand mobilization on local perfusion and upper limb (UL function in poststroke hemiparetic participants. Twenty-three patients with subacute or chronic stroke received 20 min passive mobilization of the paretic hand with robotic assistance. Near-infrared spectroscopy (NIRS was used to detect changes in forearm tissue perfusion. Muscle tone of the paretic UL was assessed by the Modified Ashworth Scale (MAS. Symptoms concerning UL heaviness, joint stiffness, and pain were evaluated as secondary outcomes by self-reporting. Significant (p=0.014 improvements were found in forearm perfusion when all fingers were mobilized simultaneously. After the intervention, MAS scores decreased globally, being the changes statistically significant for the wrist (from 1.6±1.0 to 1.1±1.0; p=0.001 and fingers (from 1.2±1.1 to 0.7±0.9; p=0.004. Subjects reported decreased UL heaviness and stiffness after treatment, especially for the hand, as well as diminished pain when present. This study supports novel evidence that hand robotic assistance promotes local UL circulation changes, may help in the management of spasticity, and acutely alleviates reported symptoms of heaviness, stiffness, and pain in subjects with poststroke hemiparesis. This opens new scenarios for the implications in everyday clinical practice. Clinical Trial Registration Number is NCT03243123.

  4. A prospective comparison of postoperative pain and quality of life in robotic assisted vs conventional laparoscopic gynecologic surgery.

    Science.gov (United States)

    Zechmeister, Jenna R; Pua, Tarah L; Boyd, Leslie R; Blank, Stephanie V; Curtin, John P; Pothuri, Bhavana

    2015-02-01

    We sought to compare robotic vs laparoscopic surgery in regards to patient reported postoperative pain and quality of life. This was a prospective study of patients who presented for treatment of a new gynecologic disease requiring minimally invasive surgical intervention. All subjects were asked to take the validated Brief Pain Inventory-Short Form at 3 time points to assess pain and its effect on quality of life. Statistical analyses were performed using Pearson x(2) and Student's t test. One hundred eleven were included in the analysis of which 56 patients underwent robotic assisted surgery and 55 patients underwent laparoscopic surgery. There was no difference in postoperative pain between conventional laparoscopy and robotic assisted surgery for gynecologic procedures. There was a statistically significant difference found at the delayed postoperative period when evaluating interference of sleep, favoring laparoscopy (ROB 2.0 vs LSC 1.0; P = .03). There were no differences found between the robotic and laparoscopic groups of patients receiving narcotics (56 vs 53, P = .24, respectively), route of administration of narcotics (47 vs 45, P > .99, respectively), or administration of nonsteroidal antiinflammatory medications (27 vs 21, P = .33, respectively). Our results demonstrate no difference in postoperative pain between conventional laparoscopy and robotic assisted surgery for gynecologic procedures. Furthermore, pain did not appear to interfere consistently with any daily activity of living. Interference of sleep needs to be further evaluated after controlling for bilateral salpingo-oophorectomy. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Changes in skeletal muscle perfusion and spasticity in patients with poststroke hemiparesis treated by robotic assistance (Gloreha) of the hand.

    Science.gov (United States)

    Bissolotti, Luciano; Villafañe, Jorge Hugo; Gaffurini, Paolo; Orizio, Claudio; Valdes, Kristin; Negrini, Stefano

    2016-03-01

    [Purpose] The purpose of this case series was to determine the effects of robot-assisted hand rehabilitation with a Gloreha device on skeletal muscle perfusion, spasticity, and motor function in subjects with poststroke hemiparesis. [Subjects and Methods] Seven patients, 2 women and 5 men (mean ± SD age: 60.5 ±6.3 years), with hemiparesis (>6 months poststroke), received passive mobilization of the hand with a Gloreha (Idrogenet, Italy), device (30 min per day; 3 sessions a week for 3 weeks). The outcome measures were the total hemoglobin profiles and tissue oxygenation index (TOI) in the muscle tissue evaluated through near-infrared spectroscopy. The Motricity Index and modified Ashworth Scale for upper limb muscles were used to assess mobility of the upper extremity. [Results] Robotic assistance reduced spasticity after the intervention by 68.6% in the upper limb. The Motricity Index was unchanged in these patients after treatment. Regarding changes in muscle perfusion, significant improvements were found in total hemoglobin. There were significant differences between the pre- and posttreatment modified Ashworth scale. [Conclusion] The present work provides novel evidence that robotic assistance of the hand induced changes in local muscle blood flow and oxygen supply, diminished spasticity, and decreased subject-reported symptoms of heaviness and stiffness in subjects with post-stroke hemiparesis.

  6. Hand Passive Mobilization Performed with Robotic Assistance: Acute Effects on Upper Limb Perfusion and Spasticity in Stroke Survivors.

    Science.gov (United States)

    Gobbo, Massimiliano; Gaffurini, Paolo; Vacchi, Laura; Lazzarini, Sara; Villafane, Jorge; Orizio, Claudio; Negrini, Stefano; Bissolotti, Luciano

    2017-01-01

    This single arm pre-post study aimed at evaluating the acute effects induced by a single session of robot-assisted passive hand mobilization on local perfusion and upper limb (UL) function in poststroke hemiparetic participants. Twenty-three patients with subacute or chronic stroke received 20 min passive mobilization of the paretic hand with robotic assistance. Near-infrared spectroscopy (NIRS) was used to detect changes in forearm tissue perfusion. Muscle tone of the paretic UL was assessed by the Modified Ashworth Scale (MAS). Symptoms concerning UL heaviness, joint stiffness, and pain were evaluated as secondary outcomes by self-reporting. Significant ( p = 0.014) improvements were found in forearm perfusion when all fingers were mobilized simultaneously. After the intervention, MAS scores decreased globally, being the changes statistically significant for the wrist (from 1.6 ± 1.0 to 1.1 ± 1.0; p = 0.001) and fingers (from 1.2 ± 1.1 to 0.7 ± 0.9; p = 0.004). Subjects reported decreased UL heaviness and stiffness after treatment, especially for the hand, as well as diminished pain when present. This study supports novel evidence that hand robotic assistance promotes local UL circulation changes, may help in the management of spasticity, and acutely alleviates reported symptoms of heaviness, stiffness, and pain in subjects with poststroke hemiparesis. This opens new scenarios for the implications in everyday clinical practice. Clinical Trial Registration Number is NCT03243123.

  7. Robot-Assisted Excision of a Pararectal Gastrointestinal Stromal Tumor in a Patient with Previous Ileal Neobladder

    Directory of Open Access Journals (Sweden)

    A. Ploumidis

    2014-01-01

    Full Text Available Gastrointestinal stromal tumors (GISTs are the most frequent mesenchymal tumors of the gastrointestinal tract with surgical resection remaining the cornerstone of therapy. Pararectal lesions are considered to be technically difficult and pose in some cases a challenge. We report, to the best of our knowledge, the first robotic-assisted pararectal GIST excision. A 43-year-old man was referred to our center with pararectal GIST recurrence, despite treatment with targeted therapy. Eleven years ago, he underwent extensive abdominal surgery including cystoprostatectomy with ileal neobladder diversion due to GIST resection in the rectoprostatic space. Robot-assisted surgical resection was successfully performed without the need for temporary colostomy. The postoperative course of the patient was uneventful, and the pathology report confirmed a GIST recurrence with negative surgical margins and pelvic lymph nodes free of any tumor. Robotic-assisted pelvic surgery can be extended to incorporate excision of pararectal GISTs, as a safe, less invasive surgical alternative with promising oncological results and minimal injury to adjacent structures.

  8. Individual finger synchronized robot-assisted hand rehabilitation in subacute to chronic stroke: a prospective randomized clinical trial of efficacy.

    Science.gov (United States)

    Hwang, Chang Ho; Seong, Jin Wan; Son, Dae-Sik

    2012-08-01

    To evaluate individual finger synchronized robot-assisted hand rehabilitation in stroke patients. Prospective parallel group randomized controlled clinical trial. The study recruited patients who were ≥18 years old, more than three months post stroke, showed limited index finger movement and had weakened and impaired hand function. Patients with severe sensory loss, spasticity, apraxia, aphasia, disabling hand disease, impaired consciousness or depression were excluded. Patients received either four weeks (20 sessions) of active robot-assisted intervention (the FTI (full-term intervention) group, 9 patients) or two weeks (10 sessions) of early passive therapy followed by two weeks (10 sessions) of active robot-assisted intervention (the HTI (half-term intervention) group, 8 patients). Patients underwent arm function assessments prior to therapy (baseline), and at 2, 4 and 8 weeks after starting therapy. Compared to baseline, both the FTI and HTI groups showed improved results for the Jebsen Taylor test, the wrist and hand subportion of the Fugl-Meyer arm motor scale, active movement of the 2nd metacarpophalangeal joint, grasping, and pinching power (P vs. 46.4 ± 37.4) and wrist and hand subportion of the Fugl-Meyer arm motor scale (4.3 ± 1.9 vs. 3.4 ± 2.5) after eight weeks. A four-week rehabilitation using a novel robot that provides individual finger synchronization resulted in a dose-dependent improvement in hand function in subacute to chronic stroke patients.

  9. Force Modeling, Identification, and Feedback Control of Robot-Assisted Needle Insertion: A Survey of the Literature

    Directory of Open Access Journals (Sweden)

    Chongjun Yang

    2018-02-01

    Full Text Available Robot-assisted surgery is of growing interest in the surgical and engineering communities. The use of robots allows surgery to be performed with precision using smaller instruments and incisions, resulting in shorter healing times. However, using current technology, an operator cannot directly feel the operation because the surgeon-instrument and instrument-tissue interaction force feedbacks are lost during needle insertion. Advancements in force feedback and control not only help reduce tissue deformation and needle deflection but also provide the surgeon with better control over the surgical instruments. The goal of this review is to summarize the key components surrounding the force feedback and control during robot-assisted needle insertion. The literature search was conducted during the middle months of 2017 using mainstream academic search engines with a combination of keywords relevant to the field. In total, 166 articles with valuable contents were analyzed and grouped into five related topics. This survey systemically summarizes the state-of-the-art force control technologies for robot-assisted needle insertion, such as force modeling, measurement, the factors that influence the interaction force, parameter identification, and force control algorithms. All studies show force control is still at its initial stage. The influence factors, needle deflection or planning remain open for investigation in future.

  10. Facilitators and barriers to adopting robotic-assisted surgery: contextualizing the unified theory of acceptance and use of technology.

    Directory of Open Access Journals (Sweden)

    Christine Benmessaoud

    Full Text Available Robotic-assisted surgical techniques are not yet well established among surgeon practice groups beyond a few surgical subspecialties. To help identify the facilitators and barriers to their adoption, this belief-elicitation study contextualized and supplemented constructs of the unified theory of acceptance and use of technology (UTAUT in robotic-assisted surgery. Semi-structured individual interviews were conducted with 21 surgeons comprising two groups: users and nonusers. The main facilitators to adoption were Perceived Usefulness and Facilitating Conditions among both users and nonusers, followed by Attitude Toward Using Technology among users and Extrinsic Motivation among nonusers. The three main barriers to adoption for both users and nonusers were Perceived Ease of Use and Complexity, Perceived Usefulness, and Perceived Behavioral Control. This study's findings can assist surgeons, hospital and medical school administrators, and other policy makers on the proper adoption of robotic-assisted surgery and can guide future research on the development of theories and framing of hypotheses.

  11. Force Modeling, Identification, and Feedback Control of Robot-Assisted Needle Insertion: A Survey of the Literature.

    Science.gov (United States)

    Yang, Chongjun; Xie, Yu; Liu, Shuang; Sun, Dong

    2018-02-12

    Robot-assisted surgery is of growing interest in the surgical and engineering communities. The use of robots allows surgery to be performed with precision using smaller instruments and incisions, resulting in shorter healing times. However, using current technology, an operator cannot directly feel the operation because the surgeon-instrument and instrument-tissue interaction force feedbacks are lost during needle insertion. Advancements in force feedback and control not only help reduce tissue deformation and needle deflection but also provide the surgeon with better control over the surgical instruments. The goal of this review is to summarize the key components surrounding the force feedback and control during robot-assisted needle insertion. The literature search was conducted during the middle months of 2017 using mainstream academic search engines with a combination of keywords relevant to the field. In total, 166 articles with valuable contents were analyzed and grouped into five related topics. This survey systemically summarizes the state-of-the-art force control technologies for robot-assisted needle insertion, such as force modeling, measurement, the factors that influence the interaction force, parameter identification, and force control algorithms. All studies show force control is still at its initial stage. The influence factors, needle deflection or planning remain open for investigation in future.

  12. Current surgical treatment option, utilizing robot-assisted laparoscopic surgery in obese women with endometrial cancer: Farghalys technique

    International Nuclear Information System (INIS)

    Farghaly, S.A.

    2013-01-01

    Background: Endometrial cancer is the most prevalent cancer of the female genital tract in North America. Minimally invasive laparoscopic-assisted surgery and panniculectomy in obese women with endometrial cancer are associated with an improved lymph node count, and lower rate of incisional complications than laparotomy. Methods: Technique for robot-assisted laparoscopic surgery for obese women with endometrial cancer is detailed. Results: Robot-assisted laparoscopic surgical staging, pelvic and para-aortic lymphadenectomy and panniculectomy allow us to avoid the use of postoperative pelvic radiation which is recommended in women with histopathology high-risk findings: deep myometrial invasion or high grade histology. The procedure has the advantage of three-dimensional vision, ergonomic, intuitive control, and wristed instrument that approximate the motion of the human hand. Conclusion: Robot-assisted laparoscopic surgical staging, and panniculectomy in these patients are a safe, and effective alternative to laparoscopic, and laparotomy surgery. It is an ideal tool for performing the complex oncologic procedures encountered in endometrial cancer staging that requires delicate retroperitoneal, pelvic and para-aortic lymph node dissection, while maintaining the principles of oncologic surgery but in a minimally invasive fashion.

  13. Robot-Assisted Body-Weight-Supported Treadmill Training in Gait Impairment in Multiple Sclerosis Patients: A Pilot Study.

    Science.gov (United States)

    Łyp, Marek; Stanisławska, Iwona; Witek, Bożena; Olszewska-Żaczek, Ewelina; Czarny-Działak, Małgorzata; Kaczor, Ryszard

    2018-02-13

    This study deals with the use of a robot-assisted body-weight-supported treadmill training in multiple sclerosis (MS) patients with gait dysfunction. Twenty MS patients (10 men and 10 women) of the mean of 46.3 ± 8.5 years were assigned to a six-week-long training period with the use of robot-assisted treadmill training of increasing intensity of the Lokomat type. The outcome measure consisted of the difference in motion-dependent torque of lower extremity joint muscles after training compared with baseline before training. We found that the training uniformly and significantly augmented the torque of both extensors and flexors of the hip and knee joints. The muscle power in the lower limbs of SM patients was improved, leading to corrective changes of disordered walking movements, which enabled the patients to walk with less effort and less assistance of care givers. The torque augmentation could have its role in affecting the function of the lower extremity muscle groups during walking. The results of this pilot study suggest that the robot-assisted body-weight-supported treadmill training may be a potential adjunct measure in the rehabilitation paradigm of 'gait reeducation' in peripheral neuropathies.

  14. On the Use of the Humanoid Bioloid System for Robot-Assisted Transcription of Mexican Spanish Speech

    Directory of Open Access Journals (Sweden)

    Santiago-Omar Caballero-Morales

    2015-12-01

    Full Text Available Within the context of service robotics (SR, the development of assistive technologies has become an important research field. However, the accomplishment of assistive tasks requires precise and fine control of the mechanic systems that integrate the robotic entity. Among the most challenging tasks in robot control, the handwriting task (transcription is of particular interest due to the fine control required to draw single and multiple alphabet characters to express words and sentences. For language learning activities, robot-assisted speech transcription can motivate the student to practice pronunciation and writing tasks in a dynamic environment. Hence, this paper is aimed to provide the techniques and models to accomplish accurate robot-assisted transcription of Spanish speech. The transcriptor is integrated by a multi-user speech recognizer for continuous speech and the kinematic models for the Mexican Spanish alphabet characters. The Bioloid system with the standard humanoid configuration and no special modifications or tools was considered for implementation. Particularly, the proposed transcriptor could perform the handwriting task with the Bioloid’s two two DOF (degrees-of-freedom arms. This enabled writing of one-line short and long sentences with small alphabet characters (width <1.0 cm. It is expected that the technique and models that integrate the transcriptor can provide support for the development of robot-assisted language learning activities for children and young adults.

  15. Intra-Abdominal Cooling System Limits Ischemia-Reperfusion Injury During Robot-Assisted Renal Transplantation.

    Science.gov (United States)

    Meier, R P H; Piller, V; Hagen, M E; Joliat, C; Buchs, J-B; Nastasi, A; Ruttimann, R; Buchs, N C; Moll, S; Vallée, J-P; Lazeyras, F; Morel, P; Bühler, L

    2018-01-01

    Robot-assisted kidney transplantation is feasible; however, concerns have been raised about possible increases in warm ischemia times. We describe a novel intra-abdominal cooling system to continuously cool the kidney during the procedure. Porcine kidneys were procured by standard open technique. Groups were as follows: Robotic renal transplantation with (n = 11) and without (n = 6) continuous intra-abdominal cooling and conventional open technique with intermittent 4°C saline cooling (n = 6). Renal cortex temperature, magnetic resonance imaging, and histology were analyzed. Robotic renal transplantation required a longer anastomosis time, either with or without the cooling system, compared to the open approach (70.4 ± 17.7 min and 74.0 ± 21.5 min vs. 48.7 ± 11.2 min, p-values system compared to the open approach group (6.5 ± 3.1°C vs. 22.5 ± 6.5°C; p = 0.001) or compared to the robotic group without the cooling system (28.7 ± 3.3°C; p system that suppresses the noncontrolled rewarming of donor kidneys during the transplant procedure and prevents ischemia-reperfusion injuries. © 2017 The Authors. American Journal of Transplantation published by Wiley Periodicals, Inc. on behalf of American Society of Transplant Surgeons.

  16. New software tools for enhanced precision in robot-assisted laser phonomicrosurgery.

    Science.gov (United States)

    Dagnino, Giulio; Mattos, Leonardo S; Caldwell, Darwin G

    2012-01-01

    This paper describes a new software package created to enhance precision during robot-assisted laser phonomicrosurgery procedures. The new software is composed of three tools for camera calibration, automatic tumor segmentation, and laser tracking. These were designed and developed to improve the outcome of this demanding microsurgical technique, and were tested herein to produce quantitative performance data. The experimental setup was based on the motorized laser micromanipulator created by Istituto Italiano di Tecnologia and the experimental protocols followed are fully described in this paper. The results show the new tools are robust and effective: The camera calibration tool reduced residual errors (RMSE) to 0.009 ± 0.002 mm under 40× microscope magnification; the automatic tumor segmentation tool resulted in deep lesion segmentations comparable to manual segmentations (RMSE= 0.160 ± 0.028 mm under 40× magnification); and the laser tracker tool proved to be reliable even during cutting procedures (RMSE= 0.073 ± 0.023 mm under 40× magnification). These results demonstrate the new software package can provide excellent improvements to the previous microsurgical system, leading to important enhancements in surgical outcome.

  17. The Impact of Training Residents on the Outcome of Robotic-Assisted Sacrocolpopexy

    Directory of Open Access Journals (Sweden)

    Mohamed A. Bedaiwy

    2012-01-01

    Full Text Available Objective. To evaluate the surgical outcomes of robotic-assisted sacrocolpopexy (RASCP before and after the incorporation of hands-on training for urology and gynecology residents. Study Design. Forty-one patients underwent RASCP between December 2008 and March 2010 with one surgeon. RASCP was performed in the context of surgical repair of complex pelvic organ prolapse and/or stress urinary incontinence. The first 20 cases (group I were performed exclusively by the attending surgeon. In the last 21 cases (group II, the urology resident performed a 50% or more of the RASCP while the gynecology resident performed the supracervical hysterectomy. The primary outcome measure was vaginal vault support at 24 weeks postoperatively based on pelvic organ prolapse quantification (POP-Q. Results. Mean ± SD operative time for the entire surgery including RASCP was 282.3±51.3 min and median EBL was 83.1±50.4 mL. Patient demographics and stage of disease did not differ between groups. Procedure time, PACU time, blood loss, and intraoperative complications were similar between groups. Follow-up POP-Q evaluations demonstrated significant correction of all points on vaginal examination for both groups (P<0.001. Conclusions. Incorporation of resident training during RASCP allows teaching of robotic surgery techniques in an effective manner without prolonging operative time or affecting the overall surgical outcome.

  18. Experimental evaluation of magnified haptic feedback for robot-assisted needle insertion and palpation.

    Science.gov (United States)

    Meli, Leonardo; Pacchierotti, Claudio; Prattichizzo, Domenico

    2017-12-01

    Haptic feedback has been proven to play a key role in enhancing the performance of teleoperated medical procedures. However, due to safety issues, commercially-available medical robots do not currently provide the clinician with haptic feedback. This work presents the experimental evaluation of a teleoperation system for robot-assisted medical procedures able to provide magnified haptic feedback to the clinician. Forces registered at the operating table are magnified and provided to the clinician through a 7-DoF haptic interface. The same interface is also used to control the motion of a 6-DoF slave robotic manipulator. The safety of the system is guaranteed by a time-domain passivity-based control algorithm. Two experiments were carried out on stiffness discrimination (during palpation and needle insertion) and one experiment on needle guidance. Our haptic-enabled teleoperation system improved the performance with respect to direct hand interaction of 80%, 306%, and 27% in stiffness discrimination through palpation, stiffness discrimination during needle insertion, and guidance, respectively. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Does training of fellows affect peri-operative outcomes of robot-assisted partial nephrectomy?

    Science.gov (United States)

    Khene, Zine-Eddine; Peyronnet, Benoit; Bosquet, Elise; Pradère, Benjamin; Robert, Corentin; Fardoun, Tarek; Kammerer-Jacquet, Solène-Florence; Verhoest, Grégory; Rioux-Leclercq, Nathalie; Mathieu, Romain; Bensalah, Karim

    2017-10-01

    To evaluate the impact of fellows' involvement on the peri-operative outcomes of robot-assisted partial nephrectomy (RAPN). We analysed 216 patients who underwent RAPN for a small renal tumour. We stratified our cohort into two groups according to the involvement of a fellow surgeon during the procedure: expert surgeon operating alone (expert group) and fellow operating under the supervision of the expert surgeon (fellow group). Peri-operative data were compared between the two groups. Linear and logistic regression analyses were performed to assess the impact of fellows' involvement on peri-operative and postoperative outcomes. Trifecta and margins ischaemia complications (MIC) score achievement rates were used to assess the quality of surgery in both the expert and fellow groups. Trifecta was defined as a combination of warm ischaemia time negative surgical margins and no peri-operative complications. MIC score was defined as negative surgical margins, ischaemia time Training fellows to perform RAPN is associated with longer operating time and WIT but does not appear to compromise other peri-operative outcomes. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  20. The Evolution of Image-Free Robotic Assistance in Unicompartmental Knee Arthroplasty.

    Science.gov (United States)

    Lonner, Jess H; Moretti, Vincent M

    2016-01-01

    Semiautonomous robotic technology has been introduced to optimize accuracy of bone preparation, implant positioning, and soft tissue balance in unicompartmental knee arthroplasty (UKA), with the expectation that there will be a resultant improvement in implant durability and survivorship. Currently, roughly one-fifth of UKAs in the US are being performed with robotic assistance, and it is anticipated that there will be substantial growth in market penetration of robotics over the next decade. First-generation robotic technology improved substantially implant position compared to conventional methods; however, high capital costs, uncertainty regarding the value of advanced technologies, and the need for preoperative computed tomography (CT) scans were barriers to broader adoption. Newer image-free semiautonomous robotic technology optimizes both implant position and soft tissue balance, without the need for preoperative CT scans and with pricing and portability that make it suitable for use in an ambulatory surgery center setting, where approximately 40% of these systems are currently being utilized. This article will review the robotic experience for UKA, including rationale, system descriptions, and outcomes.

  1. Retroperitoneal approach for robot-assisted partial nephrectomy: technique and early outcomes

    Directory of Open Access Journals (Sweden)

    A. Porreca

    Full Text Available ABSTRACT Objectives The aim of our study is to present early outcomes of our series of retroperitoneal-RAPN (Robot Assisted Partial Nephrectomy. Materials and methods From September 2010 until December 2015, we performed 81 RAPN procedures (44 at left kidney and 37 at right. Average size was 3cm (1-9. Average PADUA score 7.1 (5-10. Average surgical time (overall and only robot time, ischemia time, blood loss, pathological stage, complications and hospital stay have been recorded. Results All of the cases were completed successfully without any operative complication or surgical conversion. Average surgical time was 177 minutes (75-340. Operative time was 145 minutes (80-300, overall blood loss was 142cc (60-310cc. In 30 cases the pedicle was late clamped with an average ischemia time of 4 minutes (2-7. None of the patient had positive surgical margins at definitive histology (49pT1a, 12pT1b, 3pT2a, 2pT3a. Hospital stay was 3 days (2-7. Conclusions The retroperitoneal robotic partial nephrectomy approach is safe and allows treatment of even quite complex tumors. It also combines the already well known advantages guaranteed by the da Vinci® robotic surgical system, with the advantages of the retroperitoneoscopic approach.

  2. da Vinci robot-assisted keyhole neurosurgery: a cadaver study on feasibility and safety.

    Science.gov (United States)

    Marcus, Hani J; Hughes-Hallett, Archie; Cundy, Thomas P; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar

    2015-04-01

    The goal of this cadaver study was to evaluate the feasibility and safety of da Vinci robot-assisted keyhole neurosurgery. Several keyhole craniotomies were fashioned including supraorbital subfrontal, retrosigmoid and supracerebellar infratentorial. In each case, a simple durotomy was performed, and the flap was retracted. The da Vinci surgical system was then used to perform arachnoid dissection towards the deep-seated intracranial cisterns. It was not possible to simultaneously pass the 12-mm endoscope and instruments through the keyhole craniotomy in any of the approaches performed, limiting visualization. The articulated instruments provided greater dexterity than existing tools, but the instrument arms could not be placed in parallel through the keyhole craniotomy and, therefore, could not be advanced to the deep cisterns without significant clashing. The da Vinci console offered considerable ergonomic advantages over the existing operating room arrangement, allowing the operating surgeon to remain non-sterile and seated comfortably throughout the procedure. However, the lack of haptic feedback was a notable limitation. In conclusion, while robotic platforms have the potential to greatly enhance the performance of transcranial approaches, there is strong justification for research into next-generation robots, better suited to keyhole neurosurgery.

  3. Robotic assisted laparoscopic adrenalectomy: Initial experience from a tertiary care centre in India

    Directory of Open Access Journals (Sweden)

    Mrinal Pahwa

    2015-01-01

    Full Text Available Introduction: Laparoscopic adrenalectomy (LA is now considered the standard for treatment of surgically correctable adrenal disorders. Robotic adrenalectomy has been performed worldwide and has established itself as safe, feasible and effective approach. We hereby present the first study in robotic transperitoneal LA from Indian subcontinent. Materials and Methods: We conducted a retrospective evaluation of 25 patients who had undergone robotic assisted LA at a tertiary health centre by a single surgeon. Demographic, clinical, histopathological and perioperative outcome data were collected and analysed. Results: Mean age of the patients was 45 years (range: 27-65 years. Eleven male and 14 female patients were operated. Mean operative time was 139 min ± 30 min (range: 110-232 min and mean blood loss was 85 ml ± 12 ml (range: 34-313 ml. Mean hospital stay was 2.5 ± 1.05 days (range: 2-6 days. Mean visual analogue scale score was 3.2 (range: 1-6 mean analgesic requirement was 50 mg diclofenac daily (range: 0-150 mg. Histopathological evaluation revealed 11 adenomas, eight phaeochromocytomas, two adrenocortical carcinomas, and four myelolipomas. According to Clavien-Dindo classification, three patients developed Grade I post-operative complications namely hypotension and pleural effusion. Conclusion: Robotic adrenalectomy is safe, technically feasible and comfortable to the surgeon. It is easier to perform with a short learning curve.

  4. A Vision-Based Approach for Estimating Contact Forces: Applications to Robot-Assisted Surgery

    Directory of Open Access Journals (Sweden)

    C. W. Kennedy

    2005-01-01

    Full Text Available The primary goal of this paper is to provide force feedback to the user using vision-based techniques. The approach presented in this paper can be used to provide force feedback to the surgeon for robot-assisted procedures. As proof of concept, we have developed a linear elastic finite element model (FEM of a rubber membrane whereby the nodal displacements of the membrane points are measured using vision. These nodal displacements are the input into our finite element model. In the first experiment, we track the deformation of the membrane in real-time through stereovision and compare it with the actual deformation computed through forward kinematics of the robot arm. On the basis of accurate deformation estimation through vision, we test the physical model of a membrane developed through finite element techniques. The FEM model accurately reflects the interaction forces on the user console when the interaction forces of the robot arm with the membrane are compared with those experienced by the surgeon on the console through the force feedback device. In the second experiment, the PHANToM haptic interface device is used to control the Mitsubishi PA-10 robot arm and interact with the membrane in real-time. Image data obtained through vision of the deformation of the membrane is used as the displacement input for the FEM model to compute the local interaction forces which are then displayed on the user console for providing force feedback and hence closing the loop.

  5. Tracked "Pick-Up" Ultrasound for Robot-Assisted Minimally Invasive Surgery.

    Science.gov (United States)

    Schneider, Caitlin; Nguan, Christopher; Rohling, Robert; Salcudean, Septimiu

    2016-02-01

    We present a novel "pick-up" ultrasound transducer for intraabdominal robot-assisted minimally invasive surgery. Such a "pick-up" ultrasound transducer is inserted through an abdominal incision at the beginning of the procedure and remains in the abdominal cavity throughout, eliminating the need for a dedicated port or a patient bedside surgical assistant. The transducer has a handle that can be grasped in a repeatable manner using a da Vinci Prograsp tool, allowing the transducer to be accurately manipulated by the surgeon using the da Vinci Robot. This is one way to enable 3-D tracking of the transducer, and, thus, mapping of the vasculature. The 3-D vascular images can be used to register preoperative CT to intraoperative camera images. To demonstrate the feasibility of the approach, we use an ultrasound vessel phantom to register a CT surface model to extracted ultrasound vessel models. The 3-D vascular phantom images are generated by segmenting B-mode images and tracking the pick-up ultrasound transducer with the da Vinci kinematics, internal electromagnetic sensor, or visible fiducials suitable for camera tracking. Reconstruction results using da Vinci kinematics for tracking give a target registration error of 5.4 ± 1.7 mm.

  6. Robotic-assisted laparoscopic hysterectomy seems safe in women with early-stage endometrial cancer

    DEFF Research Database (Denmark)

    Herling, Suzanne Forsyth; Havemann, Maria Cecilie; Palle, Connie

    2015-01-01

    INTRODUCTION: Robotic surgery is increasingly used in the management of endometrial cancer; and although it is known that minimally invasive surgery reduces post-operative morbidity, the outcomes of this novel treatment should be monitored carefully. The aim of this study was to examine the incid......INTRODUCTION: Robotic surgery is increasingly used in the management of endometrial cancer; and although it is known that minimally invasive surgery reduces post-operative morbidity, the outcomes of this novel treatment should be monitored carefully. The aim of this study was to examine...... the incidence of complications according to the Clavien-Dindo scale after robotic-assisted laparoscopic hysterectomy (RALH) for early-stage endometrial cancer and atypical complex hyperplasia. The Clavien-Dindo scale grades the severity of complications. METHODS: This was a retrospective, descriptive cohort....... CONCLUSION: The types and frequency of complications observed in this study resemble those reported in similar studies of RALH for malignant gynaecologic conditions. Health-care professionals treating and caring for women with early-stage endometrial cancer should know of the types and frequency of post...

  7. Prophylactic belladonna suppositories on anesthetic recovery after robotic assisted laparoscopic prostatectomy.

    Science.gov (United States)

    Scavonetto, Federica; Lamborn, David R; McCaffrey, Joan M; Schroeder, Darrell R; Gettman, Mattew T; Sprung, Juraj; Weingarten, Toby N

    2013-06-01

    Two prospective trials have demonstrated prophylactic antimuscarinics following prostatectomy reduce pain from bladder spasms. Our practice adopted the routine administration of prophylactic belladonna and opium (B&O) suppositories to patients undergoing robotic assisted laparoscopic radical prostatectomy (RALP). The aim of this study is to determine if this change in clinical practice was associated with improvement of postoperative outcomes. The medical records of 202 patients that underwent RALP surgery who were or were not administered prophylactic B&O suppositories in the immediate postoperative period were abstracted for duration of anesthesia recovery, pain and analgesic use. Patient and surgical characteristics between groups were similar except B&O group were slightly older (p = 0.04) and administered less opioid analgesics (p = 0.05). There was no difference between groups in the duration of phase I recovery from anesthesia (p = 0.96). Multivariable adjustments for age, body mass index, American Society of Anesthesiologists physical status, and surgical duration were made, and again it was found that suppository administration had no association with phase I recovery times (p = 0.94). The use of antimuscarinic medication for bladder spams in the B&O group was less during phase I recovery (p suppositories at the immediate conclusion of RALP surgery was not associated with improvements of the postoperative course.

  8. Robot-assisted laparoscopic dismembered pyeloplasty for ureteropelvic junction obstruction: a multi-institutional experience.

    Science.gov (United States)

    Sivaraman, Ananthakrishnan; Leveillee, Raymond J; Patel, Manoj B; Chauhan, Sanket; Bracho, Jorge E; Moore, Charles R; Coelho, Rafael F; Palmer, Kenneth J; Schatloff, Oscar; Bird, Vincent G; Munver, Ravi; Patel, Vipul R

    2012-02-01

    To report a 6-year multi-institutional experience and outcomes with robot-assisted laparoscopic pyeloplasty (RLP) for the repair of ureteropelvic junction obstruction (UPJO). Between June 2002 and October 2008, 168 adult patients from 3 institutions underwent RLP for UPJO. A retrospective analysis of prospectively collected data were performed after institutional review board approval. Diagnosis was by intravenous urogram or computed tomography scan and diuretic renogram. All patients underwent RLP through a 4-port laparoscopic technique. Demographic, preoperative, operative, and postoperative endpoints for primary and secondary repair of UPJO were measured. Success was defined as a T½ of <20 minutes on diuretic renogram and symptom resolution. Pain resolution was assessed by subjective patient reports. Of 168 patients, 147 (87.5%) had primary repairs and 21 (12.5%) had secondary repairs. Of the secondary repairs, 57% had a crossing vessel etiology. Mean operative time was 134.9 minutes, estimated blood loss was 49 mL, and length of stay was 1.5 days. Mean follow-up was 39 months. Overall, 97.6% of patients had a successful outcome, with a 6.6% overall complication rate. To our knowledge, this review represents the largest multi-institutional experience of RLP with intermediate-term follow-up. RLP is a safe, efficacious, and viable option for either primary or secondary repair of UPJO with reproducible outcomes, a high success rate, and a low incidence of complications. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Carbon footprint of robotically-assisted laparoscopy, laparoscopy and laparotomy: a comparison.

    Science.gov (United States)

    Woods, Demetrius L; McAndrew, Thomas; Nevadunsky, Nicole; Hou, June Y; Goldberg, Gary; Yi-Shin Kuo, Dennis; Isani, Sara

    2015-12-01

    To date there have been no comprehensive, comparative assessments of the environmental impact of surgical modalities. Our study seeks to quantify and compare the total greenhouse gas emissions, or 'carbon footprint', attributable to three surgical modalities. A review of 150 staging procedures, employing laparotomy (LAP), conventional laparoscopy (LSC) or robotically-assisted laparoscopy (RA-LSC), was performed. The solid waste generated (kg) and energy consumed (kWh) during each case were quantified and converted into their equivalent mass of carbon dioxide (kg CO(2) e) release into the environment. The carbon footprint is the sum of the waste production and energy consumption during each surgery (kg CO(2) e). The total carbon footprint of a RA-LSC procedure is 40.3 kg CO(2) e/patient (p < 0.01). This represents a 38% increase over that of LSC (29.2 kg CO(2) e/patient; p < 0.01) and a 77% increase over LAP (22.7 kg CO(2) e/patient; p < 0.01). Our results provide clinicians, administrators and policy-makers with knowledge of the environmental impact of their decisions to facilitate adoption of sustainable practices. Copyright © 2015 John Wiley & Sons, Ltd.

  10. Preliminary analysis of force-torque measurements for robot-assisted fracture surgery.

    Science.gov (United States)

    Georgilas, Ioannis; Dagnino, Giulio; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2015-08-01

    Our group at Bristol Robotics Laboratory has been working on a new robotic system for fracture surgery that has been previously reported [1]. The robotic system is being developed for distal femur fractures and features a robot that manipulates the small fracture fragments through small percutaneous incisions and a robot that re-aligns the long bones. The robots controller design relies on accurate and bounded force and position parameters for which we require real surgical data. This paper reports preliminary findings of forces and torques applied during bone and soft tissue manipulation in typical orthopaedic surgery procedures. Using customised orthopaedic surgical tools we have collected data from a range of orthopaedic surgical procedures at Bristol Royal Infirmary, UK. Maximum forces and torques encountered during fracture manipulation which involved proximal femur and soft tissue distraction around it and reduction of neck of femur fractures have been recorded and further analysed in conjunction with accompanying image recordings. Using this data we are establishing a set of technical requirements for creating safe and dynamically stable minimally invasive robot-assisted fracture surgery (RAFS) systems.

  11. Cost analysis of open radical cystectomy versus robot-assisted radical cystectomy.

    Science.gov (United States)

    Bansal, Sukhchain S; Dogra, Tara; Smith, Peter W; Amran, Maisarah; Auluck, Ishna; Bhambra, Maninder; Sura, Manraj S; Rowe, Edward; Koupparis, Anthony

    2018-03-01

    To perform a cost analysis comparing the cost of robot-assisted radical cystectomy (RARC) with open RC (ORC) in a UK tertiary referral centre and to identify the key cost drivers. Data on hospital length of stay (LOS), operative time (OT), transfusion rate, and volume and complication rate were obtained from a prospectively updated institutional database for patients undergoing RARC or ORC. A cost decision tree model was created. Sensitivity analysis was performed to find key drivers of overall cost and to find breakeven points with ORC. Monte Carlo analysis was performed to quantify the variability in the dataset. One RARC procedure costs £12 449.87, or £12 106.12 if the robot was donated via charitable funds. In comparison, one ORC procedure costs £10 474.54. RARC is 18.9% more expensive than ORC. The key cost drivers were OT, LOS, and the number of cases performed per annum. High ongoing equipment costs remain a large barrier to the cost of RARC falling. However, minimal improvements in patient quality of life would be required to offset this difference. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  12. Safe teleoperation based on flexible intraoperative planning for robot-assisted laser microsurgery.

    Science.gov (United States)

    Mattos, Leonardo S; Caldwell, Darwin G

    2012-01-01

    This paper describes a new intraoperative planning system created to improve precision and safety in teleoperated laser microsurgeries. It addresses major safety issues related to real-time control of a surgical laser during teleoperated procedures, which are related to the reliability and robustness of the telecommunication channels. Here, a safe solution is presented, consisting in a new planning system architecture that maintains the flexibility and benefits of real-time teleoperation and keeps the surgeon in control of all surgical actions. The developed system is based on our virtual scalpel system for robot-assisted laser microsurgery, and allows the intuitive use of stylus to create surgical plans directly over live video of the surgical field. In this case, surgical plans are defined as graphic objects overlaid on the live video, which can be easily modified or replaced as needed, and which are transmitted to the main surgical system controller for subsequent safe execution. In the process of improving safety, this new planning system also resulted in improved laser aiming precision and improved capability for higher quality laser procedures, both due to the new surgical plan execution module, which allows very fast and precise laser aiming control. Experimental results presented herein show that, in addition to the safety improvements, the new planning system resulted in a 48% improvement in laser aiming precision when compared to the previous virtual scalpel system.

  13. A novel 3D-printed hybrid simulation model for robotic-assisted kidney transplantation (RAKT).

    Science.gov (United States)

    Uwechue, Raphael; Gogalniceanu, Petrut; Kessaris, Nicos; Byrne, Nick; Chandak, Pankaj; Olsburgh, Jonathon; Ahmed, Kamran; Mamode, Nizam; Loukopoulos, Ioannis

    2018-01-27

    Robotic-assisted kidney transplantation (RAKT) offers key benefits for patients that have been demonstrated in several studies. A barrier to the wider uptake of RAKT is surgical skill acquisition. This is exacerbated by the challenges of modern surgery with reduced surgical training time, patient safety concerns and financial pressures. Simulation is a well-established method of developing surgical skill in a safe and controlled environment away from the patient. We have developed a 3D printed simulation model for the key step of the kidney transplant operation which is the vascular anastomosis. The model is anatomically accurate, based on the CT scans of patients and it incorporates deceased donor vascular tissue. Crucially, it was developed to be used in the robotic operating theatre with the operating robot to enhance its fidelity. It is portable and relatively inexpensive when compared with other forms of simulation such as virtual reality or animal lab training. It thus has the potential of being more accessible as a training tool for the safe acquisition of RAKT specific skills. We demonstrate this model here.

  14. [Robot-assisted Pylorus-Preserving Partial Pancreaticoduodenectomy (Kausch-Whipple Procedure)].

    Science.gov (United States)

    Aselmann, H; Egberts, J-H; Hinz, S; Jünemann, K-P; Becker, T

    2016-04-01

    The surgical treatment of pancreatic head tumours is one of the most complex procedures in general surgery. In contrast to colorectal surgery, minimally-invasive techniques are not very commonly applied in pancreatic surgery. Both the delicate dissection along peri- and retropancreatic vessels and the extrahepatic bile ducts and subsequent reconstruction are very demanding with rigid standard laparoscopic instruments. The 4-arm robotic surgery system with angled instruments, unidirectional movement of instruments with adjustable transmission, tremor elimination and a stable, surgeon-controlled 3D-HD view is a promising platform to overcome the limitations of standard laparoscopic surgery regarding precise dissection and reconstruction in pancreatic surgery. Pancreatic head resection for mixed-type IPMN of the pancreatic head. Robot-assisted, minimally-invasive pylorus-preserving pancreaticoduodenectomy (Kausch-Whipple procedure). The robotic approach is particularly suited for complex procedures such as pylorus-preserving pancreatic head resections. The fully robotic Kausch-Whipple procedure is technically feasible and safe. The advantages of the robotic system are apparent in the delicate dissection near vascular structures, in lymph node dissection, the precise dissection of the uncinate process and, especially, bile duct and pancreatic anastomosis. Georg Thieme Verlag KG Stuttgart · New York.

  15. A new visual feedback-based magnetorheological haptic master for robot-assisted minimally invasive surgery

    Science.gov (United States)

    Choi, Seung-Hyun; Kim, Soomin; Kim, Pyunghwa; Park, Jinhyuk; Choi, Seung-Bok

    2015-06-01

    In this study, we developed a novel four-degrees-of-freedom haptic master using controllable magnetorheological (MR) fluid. We also integrated the haptic master with a vision device with image processing for robot-assisted minimally invasive surgery (RMIS). The proposed master can be used in RMIS as a haptic interface to provide the surgeon with a sense of touch by using both kinetic and kinesthetic information. The slave robot, which is manipulated with a proportional-integrative-derivative controller, uses a force sensor to obtain the desired forces from tissue contact, and these desired repulsive forces are then embodied through the MR haptic master. To verify the effectiveness of the haptic master, the desired force and actual force are compared in the time domain. In addition, a visual feedback system is implemented in the RMIS experiment to distinguish between the tumor and organ more clearly and provide better visibility to the operator. The hue-saturation-value color space is adopted for the image processing since it is often more intuitive than other color spaces. The image processing and haptic feedback are realized on surgery performance. In this work, tumor-cutting experiments are conducted under four different operating conditions: haptic feedback on, haptic feedback off, image processing on, and image processing off. The experimental realization shows that the performance index, which is a function of pixels, is different in the four operating conditions.

  16. A new visual feedback-based magnetorheological haptic master for robot-assisted minimally invasive surgery

    International Nuclear Information System (INIS)

    Choi, Seung-Hyun; Kim, Soomin; Kim, Pyunghwa; Park, Jinhyuk; Choi, Seung-Bok

    2015-01-01

    In this study, we developed a novel four-degrees-of-freedom haptic master using controllable magnetorheological (MR) fluid. We also integrated the haptic master with a vision device with image processing for robot-assisted minimally invasive surgery (RMIS). The proposed master can be used in RMIS as a haptic interface to provide the surgeon with a sense of touch by using both kinetic and kinesthetic information. The slave robot, which is manipulated with a proportional-integrative-derivative controller, uses a force sensor to obtain the desired forces from tissue contact, and these desired repulsive forces are then embodied through the MR haptic master. To verify the effectiveness of the haptic master, the desired force and actual force are compared in the time domain. In addition, a visual feedback system is implemented in the RMIS experiment to distinguish between the tumor and organ more clearly and provide better visibility to the operator. The hue-saturation-value color space is adopted for the image processing since it is often more intuitive than other color spaces. The image processing and haptic feedback are realized on surgery performance. In this work, tumor-cutting experiments are conducted under four different operating conditions: haptic feedback on, haptic feedback off, image processing on, and image processing off. The experimental realization shows that the performance index, which is a function of pixels, is different in the four operating conditions. (paper)

  17. Robot-assisted surgery: an emerging platform for human neuroscience research

    Directory of Open Access Journals (Sweden)

    Anthony Michael Jarc

    2015-06-01

    Full Text Available Classic studies in human sensorimotor control use simplified tasks to uncover fundamental control strategies employed by the nervous system. Such simple tasks are critical for isolating specific features of motor, sensory, or cognitive processes, and for inferring causality between these features and observed behavioral changes. However, it remains unclear how these theories translate to complex sensorimotor tasks or to natural behaviors. Part of the difficulty in performing such experiments has been the lack of appropriate tools for measuring complex motor skills in real-world contexts. Robot-assisted surgery (RAS provides an opportunity to overcome these challenges by enabling unobtrusive measurements of user behavior. In addition, a continuum of tasks with varying complexity – from simple tasks such as those in classic studies to highly complex tasks such as a surgical procedure – can be studied using RAS platforms. Finally, RAS includes a diverse participant population of inexperienced users all the way to expert surgeons. In this perspective, we illustrate how the characteristics of RAS systems make them compelling platforms to extend many theories in human neuroscience, as well as, to develop new theories altogether.

  18. A process evaluation: does recruitment for an exercise program through ethnically specific channels and key figures contribute to its reach and receptivity in ethnic minority mothers?

    Science.gov (United States)

    Hartman, Marieke A; Nierkens, Vera; Cremer, Stephan W; Stronks, Karien; Verhoeff, Arnoud P

    2013-08-19

    Ethnic minority women from low-income countries who live in high-income countries are more physically inactive than ethnic majority women in those countries. At the same time, they can be harder to reach with health promotion programs. Targeting recruitment channels and execution to ethnic groups could increase reach and receptivity to program participation. We explored using ethnically specific channels and key figures to reach Ghanaian, Antillean, and Surinamese mothers with an invitation for an exercise program, and subsequently, to determine the mothers' receptivity and participation. We conducted a mixed methods process evaluation in Amsterdam, The Netherlands. To recruit mothers, we employed ethnically specific community organizations and ethnically matched key figures as recruiters over Dutch health educators. Reach and participation were measured using reply cards and the attendance records from the exercise programs. Observations were made of the recruitment process. We interviewed 14 key figures and 32 mothers to respond to the recruitment channel and recruiter used. Content analysis was used to analyze qualitative data. Recruitment through ethnically specific community channels was successful among Ghanaian mothers, but less so among Antillean and Surinamese mothers. The more close-knit an ethnic community was, retaining their own culture and having poorer comprehension of the Dutch language, the more likely we were to reach mothers through ethnically specific organizations. Furthermore, we found that using ethnically matched recruiters resulted in higher receptivity to the program and, among the Ghanaian mothers in particular, in greater participation. This was because the ethnically matched recruiter was a familiar, trusted person, a translator, and a motivator who was enthusiastic, encouraging, and able to adapt her message (targeting/tailoring). Using a health expert was preferred in order to increase the credibility and professionalism of the

  19. Evaluating the effect of three-dimensional visualization on force application and performance time during robotics-assisted mitral valve repair.

    Science.gov (United States)

    Currie, Maria E; Trejos, Ana Luisa; Rayman, Reiza; Chu, Michael W A; Patel, Rajni; Peters, Terry; Kiaii, Bob B

    2013-01-01

    The purpose of this study was to determine the effect of three-dimensional (3D) binocular, stereoscopic, and two-dimensional (2D) monocular visualization on robotics-assisted mitral valve annuloplasty versus conventional techniques in an ex vivo animal model. In addition, we sought to determine whether these effects were consistent between novices and experts in robotics-assisted cardiac surgery. A cardiac surgery test-bed was constructed to measure forces applied during mitral valve annuloplasty. Sutures were passed through the porcine mitral valve annulus by the participants with different levels of experience in robotics-assisted surgery and tied in place using both robotics-assisted and conventional surgery techniques. The mean time for both the experts and the novices using 3D visualization was significantly less than that required using 2D vision (P robotic system with either 2D or 3D vision (P robotics-assisted mitral valve annuloplasty than during conventional open mitral valve annuloplasty. This finding suggests that 3D visualization does not fully compensate for the absence of haptic feedback in robotics-assisted cardiac surgery.

  20. Performance evaluation of a robot-assisted catheter operating system with haptic feedback.

    Science.gov (United States)

    Song, Yu; Guo, Shuxiang; Yin, Xuanchun; Zhang, Linshuai; Hirata, Hideyuki; Ishihara, Hidenori; Tamiya, Takashi

    2018-06-20

    In this paper, a novel robot-assisted catheter operating system (RCOS) has been proposed as a method to reduce physical stress and X-ray exposure time to physicians during endovascular procedures. The unique design of this system allows the physician to apply conventional bedside catheterization skills (advance, retreat and rotate) to an input catheter, which is placed at the master side to control another patient catheter placed at the slave side. For this purpose, a magnetorheological (MR) fluids-based master haptic interface has been developed to measure the axial and radial motions of an input catheter, as well as to provide the haptic feedback to the physician during the operation. In order to achieve a quick response of the haptic force in the master haptic interface, a hall sensor-based closed-loop control strategy is employed. In slave side, a catheter manipulator is presented to deliver the patient catheter, according to position commands received from the master haptic interface. The contact forces between the patient catheter and blood vessel system can be measured by designed force sensor unit of catheter manipulator. Four levels of haptic force are provided to make the operator aware of the resistance encountered by the patient catheter during the insertion procedure. The catheter manipulator was evaluated for precision positioning. The time lag from the sensed motion to replicated motion is tested. To verify the efficacy of the proposed haptic feedback method, the evaluation experiments in vitro are carried out. The results demonstrate that the proposed system has the ability to enable decreasing the contact forces between the catheter and vasculature.

  1. Do fibrin sealants impact negative outcomes after robot-assisted partial nephrectomy?

    Science.gov (United States)

    Cohen, Jason; Jayram, Gautam; Mullins, Jeffrey K; Ball, Mark W; Allaf, Mohamad E

    2013-10-01

    Contemporary rates of postoperative hemorrhage after partial nephrectomy (PN) are low. Commercially available hemostatic agents are commonly used during this surgery to reduce this risk despite a paucity of data supporting the practice. We assessed the impact of fibrin sealant hemostatic agents, a costly addition to surgeries, during robot-assisted partial nephrectomy (RAPN). Between 2007 and 2011, 114 consecutive patients underwent RAPN by a single surgeon (MEA). Evicel fibrin sealant was used in the first 74 patients during renorraphy. The last 40 patients had renorraphy performed without the use of any hemostatic agents. Clinicopathologic, operative, and complication data were compared between groups. Multivariate and univariate logistic regression analysis was performed to test the association between the use of fibrin sealants and operative outcomes. Patient demographic data and clinical tumor characteristics were similar between groups. The use of fibrin sealant did not increase operative time (166.3 vs 176.1 minutes, P=0.28), warm ischemia time (WIT) (14.4 vs 16.1 minutes, P=0.18), or length of hospital stay (2.6 vs 2.4 days, P=0.35). The omission of these agents did not increase estimated blood loss (116.6 vs 176.1 mL, P=0.8) or postoperative blood transfusion (0% vs 2.5%, P=0.17). Univariate analysis demonstrated no association between use of fibrin sealants and increased complications (P>0.05). Multivariable logistic regression showed no statistically significant predictive value of omission of hemostatic agents for perioperative outcomes (P>0.05). Perioperative hemorrhage and other major complications after contemporary RAPN are rare in experienced hands. In our study, the use of fibrin sealants during RAPN does not decrease the rate of complications, blood loss, or hospital stay. Furthermore, no impact is seen on operative time, WIT, or other negative outcomes. Omitting these agents during RAPN could be a safe, effective, cost-saving measure.

  2. Modular Training for Robot-Assisted Radical Prostatectomy: Where to Begin?

    Science.gov (United States)

    Lovegrove, Catherine; Ahmed, Kamran; Novara, Giacomo; Guru, Khurshid; Mottrie, Alex; Challacombe, Ben; der Poel, Henk Van; Peabody, James; Dasgupta, Prokar

    Effective training is paramount for patient safety. Modular training entails advancing through surgical steps of increasing difficulty. This study aimed to construct a modular training pathway for use in robot-assisted radical prostatectomy (RARP). It aims to identify the sequence of procedural steps that are learnt before surgeons are able to perform a full procedure without an intervention from mentor. This is a multi-institutional, prospective, observational, longitudinal study. We used a validated training tool (RARP Score). Data regarding surgeons' stage of training and progress were collected for analysis. A modular training pathway was constructed with consensus on the level of difficulty and evaluation of individual steps. We identified and recorded the sequence of steps performed by fellows during their learning curves. We included 15 urology fellows from UK, Europe, and Australia. A total of 15 surgeons were assessed by mentors in 425 RARP cases over 8 months (range: 7-79) across 15 international centers. There were substantial differences in the sequence of RARP steps according to the chronology of the procedure, difficulty level, and the order in which surgeons actually learned steps. Steps were not attempted in chronological order. The greater the difficulty, the later the cohort first undertook the step (p = 0.021). The cohort undertook steps of difficulty level I at median case number 1. Steps of difficulty levels II, III, and IV showed more variation in median case number of the first attempt. We recommend that, in the operating theater, steps be learned in order of increasing difficulty. A new modular training route has been designed. This incorporates the steps of RARP with the following order of priority: difficulty level > median case number of first attempt > most frequently undertaken in surgical training. An evidence-based modular training pathway has been developed that facilitates a safe introduction to RARP for novice surgeons. Copyright

  3. Integration of force reflection with tactile sensing for minimally invasive robotics-assisted tumor localization.

    Science.gov (United States)

    Talasaz, A; Patel, R V

    2013-01-01

    Tactile sensing and force reflection have been the subject of considerable research for tumor localization in soft-tissue palpation. The work presented in this paper investigates the relevance of force feedback (presented visually as well as directly) during tactile sensing (presented visually only) for tumor localization using an experimental setup close to one that could be applied for real robotics-assisted minimally invasive surgery. The setup is a teleoperated (master-slave) system facilitated with a state-of-the-art minimally invasive probe with a rigidly mounted tactile sensor at the tip and an externally mounted force sensor at the base of the probe. The objective is to capture the tactile information and measure the interaction forces between the probe and tissue during palpation and to explore how they can be integrated to improve the performance of tumor localization. To quantitatively explore the effect of force feedback on tactile sensing tumor localization, several experiments were conducted by human subjects to locate artificial tumors embedded in the ex vivo bovine livers. The results show that using tactile sensing in a force-controlled environment can realize, on average, 57 percent decrease in the maximum force and 55 percent decrease in the average force applied to tissue while increasing the tumor detection accuracy by up to 50 percent compared to the case of using tactile feedback alone. The results also show that while visual presentation of force feedback gives straightforward quantitative measures, improved performance of tactile sensing tumor localization is achieved at the expense of longer times for the user. Also, the quickness and intuitive data mapping of direct force feedback makes it more appealing to experienced users.

  4. Robotically assisted small intestinal strictureplasty in dogs: a survival study involving 16 Heineke-Mikulicz strictureplasties.

    Science.gov (United States)

    Sonoda, T; Lee, S; Whelan, R L; Le, D; Foglia, C; Venturero, M; Hunt, D; Nakajima, K; Milsom, J W

    2007-12-01

    Robotically assisted surgery offers the advantages of improved dexterity and elimination of tremor over conventional laparoscopic surgery. There have been few studies to date, however, examining the role of robotics in intestinal surgery. This study was undertaken to determine the feasibility and safety of using a robotic surgical system in the performance of intracorporeal small bowel strictureplasties in dogs. Using a robotic surgical system, a total of 16 strictureplasties were performed in the small bowel of eight dogs (two strictureplasties per dog). Using only intracorporeal robotic surgery, a 2.5 cm enterotomy was made longitudinally in the small bowel, and then closed in a Heineke-Mikulicz configuration with a one-layer running 3-0 braided absorbable suture (strictureplasty). All animals were allowed to survive for 7 days with prospective monitoring of bowel movements, level of activity, oral intake, and abdominal examination. After 7 days, necropsy was performed, examining all strictureplasty sites for signs of sepsis. The endpoints of the study were recovery of normal intestinal function (bowel movements), intraoperative and postoperative complications, and the appearance of the anastomoses at necropsy. There was no intraoperative morbidity or mortality. All eight dogs survived 7 days and recovered well. All dogs had a bowel movement on the first postoperative day, and appeared healthy throughout the study period. Necropsy revealed that all 16 strictureplasty sites were healing without signs of sepsis. The median time per strictureplasty was 65 min (range, 45-110 min). One dog developed a superficial wound infection at a trocar site. A robotic surgical system can successfully be employed in the performance of intestinal strictureplasties in dogs. This study supports further investigation into the role of robotics in intestinal surgery in humans.

  5. Influence of virtual reality soccer game on walking performance in robotic assisted gait training for children

    Directory of Open Access Journals (Sweden)

    Zimmerli Lukas

    2010-04-01

    Full Text Available Abstract Background Virtual reality (VR offers powerful therapy options within a functional, purposeful and motivating context. Several studies have shown that patients' motivation plays a crucial role in determining therapy outcome. However, few studies have demonstrated the potential of VR in pediatric rehabilitation. Therefore, we developed a VR-based soccer scenario, which provided interactive elements to engage patients during robotic assisted treadmill training (RAGT. The aim of this study was to compare the immediate effect of different supportive conditions (VR versus non-VR conditions on motor output in patients and healthy control children during training with the driven gait orthosis Lokomat®. Methods A total of 18 children (ten patients with different neurological gait disorders, eight healthy controls took part in this study. They were instructed to walk on the Lokomat in four different, randomly-presented conditions: (1 walk normally without supporting assistance, (2 with therapists' instructions to promote active participation, (3 with VR as a motivating tool to walk actively and (4 with the VR tool combined with therapists' instructions. The Lokomat gait orthosis is equipped with sensors at hip and knee joint to measure man-machine interaction forces. Additionally, subjects' acceptance of the RAGT with VR was assessed using a questionnaire. Results The mixed ANOVA revealed significant main effects for the factor CONDITIONS (p Conclusions The VR scenario used here induces an immediate effect on motor output to a similar degree as the effect resulting from verbal instructions by the therapists. Further research needs to focus on the implementation of interactive design elements, which keep motivation high across and beyond RAGT sessions, especially in pediatric rehabilitation.

  6. Does robot-assisted gait rehabilitation improve balance in stroke patients? A systematic review.

    Science.gov (United States)

    Swinnen, Eva; Beckwée, David; Meeusen, Romain; Baeyens, Jean-Pierre; Kerckhofs, Eric

    2014-01-01

    The aim of this systematic review was to summarize the improvements in balance after robot-assisted gait training (RAGT) in stroke patients. Two databases were searched: PubMed and Web of Knowledge. The most important key words are "stroke," "RAGT," "balance," "Lokomat," and "gait trainer." Studies were included if stroke patients were involved in RAGT protocols, and balance was determined as an outcome measurement. The articles were checked for methodological quality by 2 reviewers (Cohen's κ = 0.72). Nine studies were included (7 true experimental and 2 pre-experimental studies; methodological quality score, 56%-81%). In total, 229 subacute or chronic stroke patients (70.5% male) were involved in RAGT (3 to 5 times per week, 3 to 10 weeks, 12 to 25 sessions). In 5 studies, the gait trainer was used; in 2, the Lokomat was used; in 1 study, a single-joint wearable knee orthosis was used; and in 1 study, the AutoAmbulator was used. Eight studies compared RAGT with other gait rehabilitation methods. Significant improvements (no to large effect sizes, Cohen's d = 0.01 to 3.01) in balance scores measured with the Berg Balance Scale, the Tinetti test, postural sway tests, and the Timed Up and Go test were found after RAGT. No significant differences in balance between the intervention and control groups were reported. RAGT can lead to improvements in balance in stroke patients; however, it is not clear whether the improvements are greater compared with those associated with other gait rehabilitation methods. Because a limited number of studies are available, more specific research (eg, randomized controlled trials with larger, specific populations) is necessary to draw stronger conclusions.

  7. Outcomes of robot-assisted simple enucleation of renal masses: A single European center experience.

    Science.gov (United States)

    Matei, Deliu Victor; Vartolomei, Mihai Dorin; Musi, Gennaro; Renne, Giuseppe; Tringali, Valeria Maria Lucia; Mistretta, Francesco Alessandro; Delor, Maurizio; Russo, Andrea; Cioffi, Antonio; Bianchi, Roberto; Cozzi, Gabriele; Di Trapani, Ettore; Bottero, Danilo; Cordima, Giovanni; Lucarelli, Giuseppe; Ferro, Matteo; de Cobelli, Ottavio

    2017-05-01

    The aim of this study was to assess the ability of pre-and intraoperative parameters, to predict the risk of perioperative complications after robot-assisted laparoscopic simple enucleation (RASE) of renal masses, and to evaluate the rate of trifecta achievement of this approach stratifying the cohort according to the use of ischemia during the enucleation.From April 2009 to June 2016, 129 patients underwent RASE at our Institution. We stratified the procedures in 2 groups: clamping and clamp-less RASE. After RASE, all specimens were retrospectively reviewed to assess the surface-intermediate-base (SIB) scoring system. Patients were followed-up according to the European Association of Urology guidelines recommendations. All pre-, intra-, and postoperative outcomes were prospectively collected in a customized database and retrospectively analyzed.A total of 112 (86.8%) patients underwent a pure RASE and 17 (13.2%) had a hybrid according to SIB classification system. The mean age was 61.17 years. In 21 patients (16.3%), complications occurred, 13 (61.9%) were Clavien 1 and 2, while 8 were Clavien 3a and b complications. Statistical significant association with complications was found in patients with American Society of Anestesiology (ASA) score 3 (44.5%, P = .04), longer mean operative time (OT) 195 versus 161.36 minutes (P =.03), mean postoperative hemoglobin (Hb) 10.1 versus 11.8 (P 3, longer OT, and ΔHb. RASE is suitable for the clamp-less approach, which allows to perform easier the pure enucleation (SIB 0) and to obtain higher rates of trifecta outcomes.

  8. Effects of Robot Assisted Gait Training in Progressive Supranuclear Palsy (PSP: a preliminary report.

    Directory of Open Access Journals (Sweden)

    Patrizio eSale

    2014-04-01

    Full Text Available Background and Purpose: Progressive supranuclear palsy (PSP is a rare neurodegenerative disease clinically characterized by prominent axial extrapyramidal motor symptoms with frequent falls. Over the last years the introduction of robotic technologies to recover lower limb function has been greatly employed in the rehabilitative practice. This observational trial is aimed at investigating the feasibility, the effectiveness and the efficacy of end-effector robot training in people with PSP.Method: Pilot observational trial.Participants: Five cognitively intact participants with PSP and gait disorders.Interventions: Patients were submitted to a rehabilitative program of robot-assisted walking sessions for 45 minutes, 5 times a week for 4 weeks.Main outcome measures: The spatiotemporal parameters at the beginning (T0 and at the end of treatment (T1 were recorded by a gait analysis laboratory.Results: Robot training was feasible, acceptable and safe and all participants completed the prescribed training sessions. All patients showed an improvement in the gait index (Mean velocity, Cadence, Step length and Step width (T0 versus T1.Conclusions: Robot training is a feasible and safe form of rehabilitation for cognitively intact people with PSP. This innovative approach can contribute to improve lower limb motor recovery. The focus on gait recovery is another quality that makes this research important for clinical practice. On the whole, the simplicity of treatment, the lack of side effects and the positive results in the patients support the recommendation to extend the trials of this treatment. Further investigation regarding the effectiveness of robot training in time is necessary.Trial registration: ClinicalTrials.gov NCT01668407.

  9. Performance of da Vinci Stapler during robotic-assisted right colectomy with intracorporeal anastomosis.

    Science.gov (United States)

    Johnson, Craig S; Kassir, Andrew; Marx, Daryl S; Soliman, Mark K

    2018-05-30

    Applications for surgical staplers continue to grow, due to the increase in minimally invasive surgical approaches, and range from vessel ligation to tissue transection and anastomoses. Complications associated with stapled tissue, such as bleeding or leaks, continue to be a concern for surgeons, as both can be associated with prolonged operative times and can contribute to postoperative morbidity and mortality. The goal of this retrospective study was to evaluate the performance of the da Vinci ® Xi EndoWrist ® Stapler 45 with SmartClamp™ technology during robotic-assisted right colectomy with intracorporeal anastomosis. We reviewed 113 consecutive cases from four medical centers. Preclinical diagnoses were inflammatory bowel disease (IBD) (n = 5), benign bowel disease (n = 77), and malignant bowel disease (n = 31). No anastomotic leaks occurred; one event of anastomotic bleeding (0.88%) resolved without surgical intervention. Overall, there were 643 clamp attempts (5.7 attempts per case), and 570 fires (5.0 fires per case). SmartClamp™ occurrences happened in approximately one out of three cases, with the highest proportion of occurrences in the IBD group (2.0 occurrences per case). The most commonly fired reload was blue (1.5 mm closed height) with 4.1 blue reloads fired per case overall. No incomplete fires occurred during the procedures. The study data demonstrate the performance of the da Vinci Xi EndoWrist ® Stapler 45 as used in right colon resection with intracorporeal anastomosis. The collection and analysis of these data provide surgeons with information related to stapler firings, which were not previously available; as such, this analysis may lead to deductions that are useful for intraoperative decision-making and clinical outcomes.

  10. Extraperitoneal Robotic-Assisted Para-Aortic Lymphadenectomy in Gynecologic Cancer Staging: Current Evidence.

    Science.gov (United States)

    Bogani, Giorgio; Ditto, Antonino; Martinelli, Fabio; Signorelli, Mauro; Chiappa, Valentina; Sabatucci, Ilaria; Scaffa, Cono; Lorusso, Domenica; Raspagliesi, Francesco

    2016-01-01

    We reviewed the current evidence on the safety, effectiveness, and applicability of extraperitoneal robotic-assisted para-aortic lymphadenectomy (ExtRA-PAL) as the staging procedure of gynecologic malignancies. PubMed (MEDLINE), Scopus, Web of Science databases, and ClinicalTrials.gov were searched for original studies reporting outcomes of ExtRA-PAL. Quality of the included studies and their level of recommendation were assessed using the Grading of Recommendations, Assessment, Development, and Evaluation and the American College of Obstetricians and Gynecologists guidelines, respectively. Overall, 62 studies were identified; after a process of evidence acquisition 5 original investigations were available for this review that included 98 patients undergoing ExtRA-PAL. The main surgical indication was staging for cervical cancer (n = 71, 72%). The mean (SD) number of para-aortic node yielded was 15.4 (±4.7) nodes. Blood transfusion and intraoperative complication rates were 2% and 6%, respectively. ExtRA-PAL was completed in 88 patients (90%). Six (6%) and 4 (4%) patients had conversion to other minimally invasive procedures and open surgery, respectively. Success rate was 99% among patients undergoing ExtRA-PAL without concomitant procedures. Overall, mean (SD) length of hospital stay was 2.8 (±0.5) days. Twenty-four patients (24%) developed postoperative events. According to the Clavien-Dindo grading system, grades IIIa and IIIb morbidity rates were 12% and 2%, respectively. No grades IV and V morbidity occurred. ExtRA-PAL is associated with a high success rate and a relative low morbidity rate. However, because of the limited data on this issue, further studies are warranted to assess the long-term effectiveness of this procedure. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  11. Comprehensive analysis of sexual function outcome in prostate cancer patients after robot-assisted radical prostatectomy.

    Science.gov (United States)

    Woo, Seung Hyo; Kang, Dong Il; Ha, Yun-Sok; Salmasi, Amirali Hassanzadeh; Kim, Jeong Hyun; Lee, Dong-Hyeon; Kim, Wun-Jae; Kim, Isaac Yi

    2014-02-01

    The recovery of potency following radical prostatectomy is complex and has a very wide range. In this study, we analyzed in detail the precise pattern of recovery of potency following robot-assisted radical prostatectomy (RARP). Prospectively collected database of patients with a minimum follow-up of 1 year after RARP were evaluated retrospectively. Of 503 patients identified, 483 patients completed the sexual health inventory for men (SHIM) preoperatively and postoperatively every 3 months for the first 12 months. Overall potency, usage of phosphodiesterase type-5 (PDE-5) inhibitors, and return to baseline erectile function were evaluated. Potency was defined as having erection that is sufficient for sexual intercourse more than 50% of attempts, while quality potency was defined as being potent without the use of PDE-5 inhibitors. Preoperatively, the overall potency and quality potency rate were 67.1% and 48.1%, respectively. Postoperatively, the overall potency rate was 61.4%, while the quality potency rate was 37.2%. In multivariate regression analysis, independent predictors of potency recovery were young age (21, the overall potency and quality potency rate were 79.7% and 41.2%, respectively. More importantly, only 21.4% of the men with normal erection preoperatively (SHIM>21) returned to baseline erectile function (SHIM>21) 12 months after surgery. This study indicates that young age (<60), preoperative potency, and bilateral preservation of NVBs were positive predictors of potency recovery following RARP. However, an overwhelming majority of men experience a deterioration in the overall quality of erection after RARP.

  12. A comparison between robotic-assisted laparoscopic distal pancreatectomy versus laparoscopic distal pancreatectomy.

    Science.gov (United States)

    Goh, Brian K P; Chan, Chung Yip; Soh, Hui-Ling; Lee, Ser Yee; Cheow, Peng-Chung; Chow, Pierce K H; Ooi, London L P J; Chung, Alexander Y F

    2017-03-01

    This study aims to compare the early perioperative outcomes of robotic-assisted laparoscopic distal pancreatectomy (RDP) versus laparoscopic distal pancreatectomy (LDP). The clinicopathologic features of 45 consecutive patients who underwent minimally-invasive distal pancreatectomy from 2006 to 2015 were retrospectively reviewed. Thirty-nine patients who met our study criteria were included. Eight patients underwent RDP and 31 had LDP. There were 10 (25.6%) open conversions. Six (15.4%) patients had major (> grade 2) morbidities and there was no in-hospital mortality. There were 14 (35.9%) grade A and 9 (23.1%) grade B pancreatic fistulas. Comparison between RDP and LDP demonstrated no significant difference between the patients' baseline characteristics except there was increased frequency of spleen-preserving pancreatectomies (3 (37.5%) vs 25 (80.6%), P=0.016) and splenic-vessel preservation (5 (62.5%) vs 4 (12.9%), P=0.003) in RDP. Comparison between outcomes demonstrated that RDP was associated with a longer median operation time (452.5 (range, 300-685) vs 245 min (range, 85-430), P=0.001) and increased frequency of the procedure completed purely laparoscopically (8 (100%) vs 18 (58.1%), P=0.025). RDP can be safely adopted and is equivalent to LDP in most perioperative outcomes. It is also associated with a decreased frequency of the need for hand-assistance laparoscopic surgery or open conversion but needed a longer operation time. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Investigating perioperative heart migration during robot-assisted coronary artery bypass grafting interventions.

    Science.gov (United States)

    Linte, Cristian A; Cho, Daniel S; Wedlake, Chris; Moore, John; Chen, Elvis; Bainbridge, Daniel; Patel, Rajni; Peters, Terry; Kiaii, Bob B

    2011-09-01

    : For robot-assisted coronary artery bypass graft interventions, surgeons typically use a preoperative thoracic computed tomography scan of the patient to plan the procedure. However, the cardiac anatomy is prone to changes induced perioperatively in the effort to access the heart and surgical targets, which, in turn, may invalidate the initial plan. This article presents a method to estimate the perioperative heart migration, information which can be further exploited to refine the preoperative surgical plan. : Tracked transesophageal ultrasound images of four patients' hearts were acquired at each stage in the procedure: before lung deflation, after lung deflation, and after both lung deflation and CO2 thoracic insufflation. Anatomic features of interest-the mitral and aortic valves-were identified from each dataset, and their movement between the different procedure stages was recorded and used to estimate the global heart displacement. Moreover, the local morphology of the features of interest was investigated to provide insight on the extent of the deformation the heart has undergone during the workflow. : The study suggested that the heart does undergo substantial displacement-on the order of 10 to 15 mm in each direction (axial, coronal, and sagittal) after lung deflation and CO2 thoracic insufflation. However, no significant differences (P > 0.1) were observed in the morphologic characteristics of the features of interest across the multiple workflow stages, suggesting that local deformations occur at a much smaller scale compared with the global migration. : The quantification of the perioperatively induced changes is critical to track the displacement of the heart and surgical targets. The recorded migration patterns should not be ignored but rather be used to update the surgical plan to better suit the intraoperative environment.

  14. Retention of fundamental surgical skills learned in robot-assisted surgery.

    Science.gov (United States)

    Suh, Irene H; Mukherjee, Mukul; Shah, Bhavin C; Oleynikov, Dmitry; Siu, Ka-Chun

    2012-12-01

    Evaluation of the learning curve for robotic surgery has shown reduced errors and decreased task completion and training times compared with regular laparoscopic surgery. However, most training evaluations of robotic surgery have only addressed short-term retention after the completion of training. Our goal was to investigate the amount of surgical skills retained after 3 months of training with the da Vinci™ Surgical System. Seven medical students without any surgical experience were recruited. Participants were trained with a 4-day training program of robotic surgical skills and underwent a series of retention tests at 1 day, 1 week, 1 month, and 3 months post-training. Data analysis included time to task completion, speed, distance traveled, and movement curvature by the instrument tip. Performance of the participants was graded using the modified Objective Structured Assessment of Technical Skills (OSATS) for robotic surgery. Participants filled out a survey after each training session by answering a set of questions. Time to task completion and the movement curvature was decreased from pre- to post-training and the performance was retained at all the corresponding retention periods: 1 day, 1 week, 1 month, and 3 months. The modified OSATS showed improvement from pre-test to post-test and this improvement was maintained during all the retention periods. Participants increased in self-confidence and mastery in performing robotic surgical tasks after training. Our novel comprehensive training program improved robot-assisted surgical performance and learning. All trainees retained their fundamental surgical skills for 3 months after receiving the training program.

  15. The impact of days off between cases on perioperative outcomes for robotic-assisted laparoscopic prostatectomy.

    Science.gov (United States)

    Pearce, Shane M; Pariser, Joseph J; Patel, Sanjay G; Anderson, Blake B; Eggener, Scott E; Zagaja, Gregory P

    2016-02-01

    To examine the effect of days off between cases on perioperative outcomes for robotic-assisted laparoscopic prostatectomy (RALP). We analyzed a single-surgeon series of 2036 RALP cases between 2003 and 2014. Days between cases (DBC) was calculated as the number of days elapsed since the surgeon's previous RALP with the second start cases assigned 0 DBC. Surgeon experience was assessed by dividing sequential case experience into cases 0-99, cases 100-249, cases 250-999, and cases 1000+ based on previously reported learning curve data for RALP. Outcomes included estimated blood loss (EBL), operative time (OT), and positive surgical margins (PSMs). Multiple linear regression was used to assess the impact of the DBC and surgeon experience on EBL, OT, and PSM, while controlling for patient characteristics, surgical technique, and pathologic variables. Overall median DBC was 1 day (0-3) and declined with increasing surgeon case experience. Multiple linear regression demonstrated that each additional DBC was independently associated with increased EBL [β = 3.7, 95% CI (1.3-6.2), p < 0.01] and OT [β = 2.3 (1.4-3.2), p < 0.01], but was not associated with rate of PSM [β = 0.004 (-0.003-0.010), p = 0.2]. Increased experience was also associated with reductions in EBL and OT (p < 0.01). Surgeon experience of 1000+ cases was associated with a 10% reduction in PSM rate (p = 0.03) compared to cases 0-99. In a large single-surgeon RALP series, DBC was associated with increased blood loss and operative time, but not associated with positive surgical margins, when controlling for surgeon experience.

  16. A Novel Technique for Duodenal Resection and Primary Anastomosis With Robotic Assistance and OrVil.

    Science.gov (United States)

    Bedirli, Abdulkadir; Salman, Bulent; Nasirov, Mahir; Dogan, Ibrahim

    2017-01-01

    Benign duodenal neoplasm is a rare occurrence. Minimally invasive tumor resection and anastomosis formation with an OrVil catheter is a novel approach to treating this disease. In this article, we present a new technique for duodenojejunal anastomosis. This technique was applied in 4 patients with benign distal duodenal tumors who were treated with minimally invasive surgery with robotic assistance. In 4 patients, after the removal of distal duodenal masses with a robotic technique, an orifice in the duodenum was opened to allow for the passage of a guidewire. The guidewire was removed from the orifice by holding it with forceps during an upper endoscopy. An OrVil catheter was sutured to the guidewire outside to allow 2 catheters to proceed consecutively. After the removal of the anvil, an end-lateral duodenojejunostomy was performed with a circular stapler. The patients included 3 men and 1 woman (average age, 56). The durations of the operations were 215, 175, 180, and 185 minutes. No complications were observed in any of the patients during the postoperative period. The patients began oral intake on the fifth day of the postoperative period, and they were discharged on the sixth postoperative day. Histopathologic analyses indicated that the removed tumors were adenomas in 2 patients and gastrointestinal stromal tumors (GISTs) in 2 patients. Clear surgical margins were observed in all of the patients. The placement of an OrVil catheter for anastomosis in benign neoplasms with distal duodenum localization and the subsequent achievement of duodenojejunal anastomosis with a circular stapler constitute a novel treatment approach.

  17. Cognitive skills assessment during robot-assisted surgery: separating the wheat from the chaff.

    Science.gov (United States)

    Guru, Khurshid A; Esfahani, Ehsan T; Raza, Syed J; Bhat, Rohit; Wang, Katy; Hammond, Yana; Wilding, Gregory; Peabody, James O; Chowriappa, Ashirwad J

    2015-01-01

    To investigate the utility of cognitive assessment during robot-assisted surgery (RAS) to define skills in terms of cognitive engagement, mental workload, and mental state; while objectively differentiating between novice and expert surgeons. In all, 10 surgeons with varying operative experience were assigned to beginner (BG), combined competent and proficient (CPG), and expert (EG) groups based on the Dreyfus model. The participants performed tasks for basic, intermediate and advanced skills on the da Vinci Surgical System. Participant performance was assessed using both tool-based and cognitive metrics. Tool-based metrics showed significant differences between the BG vs CPG and the BG vs EG, in basic skills. While performing intermediate skills, there were significant differences only on the instrument-to-instrument collisions between the BG vs CPG (2.0 vs 0.2, P = 0.028), and the BG vs EG (2.0 vs 0.1, P = 0.018). There were no significant differences between the CPG and EG for both basic and intermediate skills. However, using cognitive metrics, there were significant differences between all groups for the basic and intermediate skills. In advanced skills, there were no significant differences between the CPG and the EG except time (1116 vs 599.6 s), using tool-based metrics. However, cognitive metrics revealed significant differences between both groups. Cognitive assessment of surgeons may aid in defining levels of expertise performing complex surgical tasks once competence is achieved. Cognitive assessment may be used as an adjunct to the traditional methods for skill assessment during RAS. © 2014 The Authors. BJU International © 2014 BJU International.

  18. A Fully Actuated Robotic Assistant for MRI-Guided Prostate Biopsy and Brachytherapy

    Science.gov (United States)

    Li, Gang; Su, Hao; Shang, Weijian; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Fischer, Gregory S.

    2014-01-01

    Intra-operative medical imaging enables incorporation of human experience and intelligence in a controlled, closed-loop fashion. Magnetic resonance imaging (MRI) is an ideal modality for surgical guidance of diagnostic and therapeutic procedures, with its ability to perform high resolution, real-time, high soft tissue contrast imaging without ionizing radiation. However, for most current image-guided approaches only static pre-operative images are accessible for guidance, which are unable to provide updated information during a surgical procedure. The high magnetic field, electrical interference, and limited access of closed-bore MRI render great challenges to developing robotic systems that can perform inside a diagnostic high-field MRI while obtaining interactively updated MR images. To overcome these limitations, we are developing a piezoelectrically actuated robotic assistant for actuated percutaneous prostate interventions under real-time MRI guidance. Utilizing a modular design, the system enables coherent and straight forward workflow for various percutaneous interventions, including prostate biopsy sampling and brachytherapy seed placement, using various needle driver configurations. The unified workflow compromises: 1) system hardware and software initialization, 2) fiducial frame registration, 3) target selection and motion planning, 4) moving to the target and performing the intervention (e.g. taking a biopsy sample) under live imaging, and 5) visualization and verification. Phantom experiments of prostate biopsy and brachytherapy were executed under MRI-guidance to evaluate the feasibility of the workflow. The robot successfully performed fully actuated biopsy sampling and delivery of simulated brachytherapy seeds under live MR imaging, as well as precise delivery of a prostate brachytherapy seed distribution with an RMS accuracy of 0.98mm. PMID:25076821

  19. Role of robot-assisted radical prostatectomy in the management of high-risk prostate cancer

    Directory of Open Access Journals (Sweden)

    Akshay Sood

    2014-01-01

    Full Text Available We aimed to evaluate the role of robot-assisted radical prostatectomy (RARP in the management of high-risk prostate cancer (PCa, with a focus on oncological, functional and perioperative outcomes. Further, we also aimed to briefly describe our novel modification to conventional RARP that allows immediate organ retrieval and examination for intra-operative surgical margin assessment. A literature search of PubMed was performed for articles on the management of high-risk PCa. Papers written in English and concerning clinical outcomes following RARP for locally advanced and high-risk PCa were selected. Outcomes data from our own center were also included. A total of 10 contemporary series were evaluated. Biopsy Gleason score ≥ 8 was the most common cause for classification of patients into the high-risk PCa group. Biochemical failure rate, in the few series that looked at long-term follow-up, varied from 9% to 26% at 1 year. The positive surgical margin rate varied from 12% to 53.3%. Urinary continence rates varied from 78% to 92% at 1 year. The overall complication rates varied from 2.4% to 30%, with anastomotic leak and lymphocele being the most common complications. Long-term data on oncological control following RARP in high-risk patients is lacking. Short-term oncological outcomes and functional outcomes are equivalent to open radical prostatectomy (RP. Safety outcomes are better in patients undergoing RARP when compared with open RP. Improved tools for predicting the presence of organ-confined disease (OCD are available. High-risk patients with OCD would be ideal candidates for RARP and would benefit most from surgery alone.

  20. Chylous ascites as a complication of left sided robot-assisted laparoscopic partial nephrectomy

    Directory of Open Access Journals (Sweden)

    Gaurav Pahouja

    2016-10-01

    Full Text Available Objective: The aim of the study was to present a case series of the sparsely reported complication of chylous ascites (CA after left sided robot-assisted laparoscopic partial nephrectomy (RALPN, identify possible risk factors for the development of postoperative CA, and explore current recommendations for identification, management and prevention of CA. Material and methods: A retrospective review of patients that were treated with a RALPN during a one year time period (August 2012 to August 2013 by one surgeon at our institution was conducted. A total of 12 patients were included in the study. Demographics, tumor characteristics, and perioperative outcomes were assessed. Results: Three patients in the study experienced postoperative CA. All three patients had left sided surgery. The initial clinical suspicion for CA was raised due to complaints of abdominal pain with increased milky appearance of JP fluid. JP triglycerides were elevated in all three patients. The patients responded to conservative measures, with two patients treated with medium chain triglyceride diets and one patient treated with total parenteral nutrition (TPN. Among the patients treated with RALPN, the group that was diagnosed with postoperative CA (CA group was found to have a statistically significant lower average body mass index (BMI as compared to the group that did not have CA (non-CA group (24.67 kg/m2 in the CA group versus 31.77 kg/m2 in the non-CA group; P = 0.026. Other demographic data, tumor characteristics, and perioperative outcomes were similar in both groups. Conclusions: CA as a result of RALPN is a newly reported and rare postoperative complication. As utilization of RALPN continues to increase, urologists should be aware of this possible complication and be adept at diagnosing and managing CA. We suggest that left sided retroperitoneal surgery and a lower BMI preoperatively be considered risk factors for developing this complication.

  1. Optic nerve sheath diameter remains constant during robot assisted laparoscopic radical prostatectomy.

    Directory of Open Access Journals (Sweden)

    Philip Verdonck

    Full Text Available During robot assisted laparoscopic radical prostatectomy (RALRP, a CO2 pneumoperitoneum (CO2PP is applied and the patient is placed in a head-down position. Intracranial pressure (ICP is expected to acutely increase under these conditions. A non-invasive method, the optic nerve sheath diameter (ONSD measurement, may warn us that the mechanism of protective cerebrospinal fluid (CSF shifts becomes exhausted.After obtaining IRB approval and written informed consent, ONSD was measured by ocular ultrasound in 20 ASA I-II patients at various stages of the RALRP procedure: baseline awake, after induction, after applying the CO2PP, during head-down position, after resuming the supine position, in the postoperative anaesthesia care unit, and on day one postoperatively. Cerebral perfusion pressure (CPP was calculated as the mean arterial (MAP minus central venous pressure (CVP.The ONSD did not change during head-down position, although the CVP increased from 4.2(2.5 mm Hg to 27.6(3.8 mm Hg. The CPP was decreased 70 min after assuming the head-down position until 15 min after resuming the supine position, but remained above 60 mm Hg at all times.Even though ICP has been documented to increase during CO2PP and head-down positioning, we did not find any changes in ONSD during head-down position. These results indicate that intracranial blood volume does not increase up to a point that CSF migration as a compensation mechanism becomes exhausted, suggesting any increases in ICP are likely to be small.

  2. Control strategies for effective robot assisted gait rehabilitation: the state of art and future prospects.

    Science.gov (United States)

    Cao, Jinghui; Xie, Sheng Quan; Das, Raj; Zhu, Guo L

    2014-12-01

    A large number of gait rehabilitation robots, together with a variety of control strategies, have been developed and evaluated during the last decade. Initially, control strategies applied to rehabilitation robots were adapted from those applied to traditional industrial robots. However, these strategies cannot optimise effectiveness of gait rehabilitation. As a result, researchers have been investigating control strategies tailored for the needs of rehabilitation. Among these control strategies, assisted-as-needed (AAN) control is one of the most popular research topics in this field. AAN training strategies have gained the theoretical and practical evidence based backup from motor learning principles and clinical studies. Various approaches to AAN training have been proposed and investigated by research groups all around the world. This article presents a review on control algorithms of gait rehabilitation robots to summarise related knowledge and investigate potential trends of development. There are existing review papers on control strategies of rehabilitation robots. The review by Marchal-Crespo and Reinkensmeyer (2009) had a broad cover of control strategies of all kinds of rehabilitation robots. Hussain et al. (2011) had specifically focused on treadmill gait training robots and covered a limited number of control implementations on them. This review article encompasses more detailed information on control strategies for robot assisted gait rehabilitation, but is not limited to treadmill based training. It also investigates the potential to further develop assist-as-needed gait training based on assessments of patients' ability. In this paper, control strategies are generally divided into the trajectory tracking control and AAN control. The review covers these two basic categories, as well as other control algorithm and technologies derived from them, such as biofeedback control. Assessments on human gait ability are also included to investigate how to

  3. Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy.

    Directory of Open Access Journals (Sweden)

    Shaoli Liu

    Full Text Available The "robotic-assisted liver tumor coagulation therapy" (RALTCT system is a promising candidate for large liver tumor treatment in terms of accuracy and speed. A prerequisite for effective therapy is accurate surgical planning. However, it is difficult for the surgeon to perform surgical planning manually due to the difficulties associated with robot-assisted large liver tumor therapy. These main difficulties include the following aspects: (1 multiple needles are needed to destroy the entire tumor, (2 the insertion trajectories of the needles should avoid the ribs, blood vessels, and other tissues and organs in the abdominal cavity, (3 the placement of multiple needles should avoid interference with each other, (4 an inserted needle will cause some deformation of liver, which will result in changes in subsequently inserted needles' operating environment, and (5 the multiple needle-insertion trajectories should be consistent with the needle-driven robot's movement characteristics. Thus, an effective multiple-needle surgical planning procedure is needed. To overcome these problems, we present an automatic multiple-needle surgical planning of optimal insertion trajectories to the targets, based on a mathematical description of all relevant structure surfaces. The method determines the analytical expression of boundaries of every needle "collision-free reachable workspace" (CFRW, which are the feasible insertion zones based on several constraints. Then, the optimal needle insertion trajectory within the optimization criteria will be chosen in the needle CFRW automatically. Also, the results can be visualized with our navigation system. In the simulation experiment, three needle-insertion trajectories were obtained successfully. In the in vitro experiment, the robot successfully achieved insertion of multiple needles. The proposed automatic multiple-needle surgical planning can improve the efficiency and safety of robot-assisted large liver tumor

  4. Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy.

    Science.gov (United States)

    Liu, Shaoli; Xia, Zeyang; Liu, Jianhua; Xu, Jing; Ren, He; Lu, Tong; Yang, Xiangdong

    2016-01-01

    The "robotic-assisted liver tumor coagulation therapy" (RALTCT) system is a promising candidate for large liver tumor treatment in terms of accuracy and speed. A prerequisite for effective therapy is accurate surgical planning. However, it is difficult for the surgeon to perform surgical planning manually due to the difficulties associated with robot-assisted large liver tumor therapy. These main difficulties include the following aspects: (1) multiple needles are needed to destroy the entire tumor, (2) the insertion trajectories of the needles should avoid the ribs, blood vessels, and other tissues and organs in the abdominal cavity, (3) the placement of multiple needles should avoid interference with each other, (4) an inserted needle will cause some deformation of liver, which will result in changes in subsequently inserted needles' operating environment, and (5) the multiple needle-insertion trajectories should be consistent with the needle-driven robot's movement characteristics. Thus, an effective multiple-needle surgical planning procedure is needed. To overcome these problems, we present an automatic multiple-needle surgical planning of optimal insertion trajectories to the targets, based on a mathematical description of all relevant structure surfaces. The method determines the analytical expression of boundaries of every needle "collision-free reachable workspace" (CFRW), which are the feasible insertion zones based on several constraints. Then, the optimal needle insertion trajectory within the optimization criteria will be chosen in the needle CFRW automatically. Also, the results can be visualized with our navigation system. In the simulation experiment, three needle-insertion trajectories were obtained successfully. In the in vitro experiment, the robot successfully achieved insertion of multiple needles. The proposed automatic multiple-needle surgical planning can improve the efficiency and safety of robot-assisted large liver tumor therapy

  5. Occult Radiographically Evident Port-Site Hernia After Robot-Assisted Urologic Surgery: Incidence and Risk Factors.

    Science.gov (United States)

    Christie, Matthew C; Manger, Jules P; Khiyami, Abdulaziz M; Ornan, Afshan A; Wheeler, Karen M; Schenkman, Noah S

    2016-01-01

    Laparoscopic trocar-site hernias (TSH) are rare, with a reported incidence of 1% or less. The incidence of occult radiographically evident hernias has not been described after robot-assisted urologic surgery. We evaluated the incidence and risk factors of this problem. A single-institution retrospective review of robot-assisted urologic surgery was performed from April 2009 to December 2012. Patients with preoperative and postoperative CT were included for analysis. Imaging was reviewed by two radiologists and one urologist. One hundred four cases were identified, including 60 partial nephrectomy, 38 prostatectomy, and 6 cystectomy. Mean age was 58 years and mean body mass index (BMI) was 29 kg/m(2). The cohort was 77% male. Ten total hernias were identified by CT in 8 patients, 2 of which were clinically evident hernias. Excluding these two hernias, occult port-site hernias were identified radiographically in seven patients. Per-patient incidence of occult TSH was 6.7% (7/104), and per-port incidence was 1.4% (8/564). All hernias were midline and 30% contained bowel. Eight of the 10 occurred at 12 mm sites (p = 0.0065) and 3 of the 10 occurred at extended incisions. Age, gender, BMI, smoking status, diabetes mellitus, immunosuppressive drug therapy, ASA score, procedure, blood loss, prior abdominal surgery, and history of hernia were not significant risk factors. Specimen size >40 g (p = 0.024) and wound infection (p = 0.0052) were significant risk factors. While the incidence of clinically evident port-site hernia remains low in robot-assisted urologic surgery, the incidence of CT-detected occult hernia was 6.7% in this series. These occurred most often in sites extended for specimen extraction and at larger port sites. This suggests more attention should be paid to fascial closure at these sites.

  6. Robot-assisted laparoscopic radical prostatectomy with early retrograde release of the neurovascular bundle and endopelvic fascia sparing

    Directory of Open Access Journals (Sweden)

    George Augusto Monteiro Lins de Albuquerque

    Full Text Available ABSTRACT Introduction Robotic-assisted radical prostatectomy (RAP is the dominant minimally invasive surgical treatment for patients with localized prostate cancer. The introduction of robotic assistance has the potential to improve surgical outcomes and reduce the steep learning curve associated with conventional laparoscopic radical prostatectomy. The purpose of this video is to demonstrate the early retrograde release of the neurovascular bundle without open the endopelvic fascia during RAP. Materials and Methods A 51-year old male, presenting histological diagnosis of prostate adenocarcinoma, Gleason 6 (3+3, in 4 cores of 12, with an initial PSA=3.41ng/dl and the digital rectal examination demonstrating a prostate with hardened nodule in the right lobe of the prostate base (clinical stage T2a. Surgical treatment with the robot-assisted technique was offered as initial therapeutic option and the critical technical point was the early retrograde release of the neurovascular bundle with endopelvic fascia preservation, during radical prostatectomy. Results The operative time was of 89 minutes, blood loss was 100ml. No drain was left in the peritoneal cavity. The patient was discharged within 24 hours. There were no intraoperative or immediate postoperative complications. The pathological evaluation revealed prostate adenocarcinoma, Gleason 6, with free surgical margins and seminal vesicles free of neoplastic involvement (pathologic stage T2a. At 3-month-follow-up, the patient lies with undetectable PSA, continent and potent. Conclusion This is a feasible technique combining the benefits of retrograde release of the neurovascular bundle, the preservation of the pubo-prostatic collar and the preservation of the antero-lateral cavernous nerves.

  7. Robotic-Assisted Fluorescence Sentinel Lymph Node Mapping Using Multi-Modal Image-Guidance in an Animal Model

    Science.gov (United States)

    Liss, Michael A.; Stroup, Sean P.; Cand, Zhengtao Qin; Hoh, Carl; Hall, David J.; Vera, David R.; Kane, Christopher J.

    2015-01-01

    Objectives To investigate PET/CT pre-operative imaging and intraoperative detection of a fluorescent-labeled receptor-targeted radiopharmaceutical in a prostate cancer animal model. Methods Three male Beagle dogs underwent an intra-prostatic injection of fluorescent-tagged tilmanocept radio-labeled with both gallium-68 and technetium-99m. One hour after injection a pelvic PET/CT scan was performed for pre-operative sentinel lymph node (SLN) mapping. Definition of SLN was a standardized uptake value (SUV) that exceeded 5% of the lymph node with the highest SUV. Thirty-six hours later we performed robotic-assisted SLN dissection using a fluorescence-capable camera system. Fluorescent lymph nodes were clipped, the abdomen was opened, and the pelvic and retroperitoneal nodes were excised. All excised nodal packets were assayed by in vitro nuclear counting and reported as percent-of-injected dose. Results Pre-operative PET/CT imaging identified a median of three sentinel lymph nodes per animal. All sentinel lymph nodes (100%) identified by the PET/CT were fluorescent during robotic-assisted lymph node dissection. Of all fluorescent nodes visualized by the camera system, 83% (10/12) satisfied the 5%-rule defined by the PET/CT scan. The two lymph nodes that did not qualify accumulated less than 0.002% of the injected dose. Conclusions Fluorescent-labeled tilmanocept has optimal logistical properties to obtain pre-operative PET/CT and subsequent real-time intraoperative confirmation during robotic-assisted sentinel lymph node dissection. PMID:25139676

  8. A short-term cost-effectiveness study comparing robot-assisted laparoscopic and open retropubic radical prostatectomy

    DEFF Research Database (Denmark)

    Hohwü, Lena; Borre, Michael; Ehlers, Lars

    2011-01-01

    OBJECTIVE: To evaluate cost effectiveness and cost utility comparing robot-assisted laparoscopic prostatectomy (RALP) versus retropubic radical prostatectomy (RRP). METHODS: In a retrospective cohort study a total of 231 men between the age of 50 and 69 years and with clinically localised prostate....... An economic evaluation was made to estimate direct costs of the first postoperative year and an incremental cost-effectiveness ratio (ICER) per successful surgical treatment and per quality-adjusted life-year (QALY). A successful RP was defined as: no residual cancer (PSA ... high volume urology centres and utilise the full potential of each robot....

  9. A Comparative Study of Single-Port Laparoscopic Surgery Versus Robotic-Assisted Laparoscopic Surgery for Rectal Cancer

    DEFF Research Database (Denmark)

    Levic, Katarina; Donatsky, Anders Meller; Bulut, Orhan

    2015-01-01

    INTRODUCTION: Conventional laparoscopic surgery is the treatment of choice for many abdominal procedures. To further reduce surgical trauma, new minimal invasive procedures such as single-port laparoscopic surgery (SPLS) and robotic assisted laparoscopic surgery (RALS) have emerged. The aim...... in either of the groups. There was no difference in median follow-up time between groups (P = .58). CONCLUSION: Both SPLS and RALS may have a role in rectal surgery. The short-term oncological outcomes were similar, although RALS harvested more lymph nodes than the SPLS procedure. However, SPLS seems...

  10. Plasma pro-atrial natriuretic peptide to estimate fluid balance during open and robot-assisted esophagectomy

    DEFF Research Database (Denmark)

    Strandby, Rune Broni; Ambrus, Rikard; Secher, Niels H

    2017-01-01

    BACKGROUND: It remains debated how much fluid should be administered during surgery. The atrial natriuretic peptide precursor proANP is released by atrial distension and deviations in plasma proANP are reported associated with perioperative fluid balance. We hypothesized that plasma proANP would...... decrease when the central blood volume is compromised during the abdominal part of robot-assisted hybrid (RE) esophagectomy and that a positive fluid balance would be required to maintain plasma proANP. METHODS: Patients undergoing RE (n = 25) or open (OE; n = 25) esophagectomy for gastroesophageal cancer...

  11. Unidirectional barbed suture versus standard monofilament for urethrovesical anastomosis during robotic assisted laparoscopic radical prostatectomy

    Directory of Open Access Journals (Sweden)

    Marc Manganiello

    2012-02-01

    Full Text Available PURPOSE: V-LocTM180 (Covidien Healthcare, Mansfield, MA is a new unidirectional barbed suture that may reduce loss of tension during a running closure. We evaluated the use of the barbed suture for urethrovesical anastomosis (UVA during robotic assisted laparoscopic prostatectomy (RALP. Time to completion of UVA, post-operative anastomotic leak rate, and urinary incontinence were compared in patients undergoing UVA with 3-0 unidirectional-barbed suture vs. 3-0 MonocrylTM (Ethicon, Somerville, NJ. MATERIALS AND METHODS: Data were prospectively collected for 70 consecutive patients undergoing RALP for prostate cancer between November 2009 and October 2010. In the first 35 patients, the UVA was performed using a modified running van Velthoven anastomosis technique using two separate 3-0 monofilament sutures. In the subsequent 35 patients, the UVA was performed using two running novel unidirectional barbed sutures. At 7-12 days postoperatively, all patients were evaluated with a cystogram to determine anastomotic integrity. Urinary incontinence was assessed at two months and five months by total daily pad usage. Clinical symptoms suggestive of bladder neck contracture were elicited. RESULTS: Age, PSA, Gleason score, prostate size, estimated blood loss, body mass index, and clinical and pathologic stage between the 2 groups were similar. Comparing the monofilament group and V-LocTM180 cohorts, average time to complete the anastomosis was similar (27.4 vs. 26.4 minutes, p = 0.73 as was the rate of urinary extravasation on cystogram (5.7 % vs. 8.6%, p = 0.65. There were no symptomatic bladder neck contractures noted at 5 months of follow-up. At 2 months, the percentage of patients using 2 or more pads per day was lower in the V-LocTM180 cohort (24% vs. 44%, p < 0.02. At 5 months, this difference was no longer evident. CONCLUSIONS: Time to complete the UVA was similar in the intervention and control groups. Rates of urine leak were also comparable

  12. [Thymomectomy by minimally invasive surgery. Comparative study videosurgery versus robot-assisted surgery].

    Science.gov (United States)

    Witte Pfister, A; Baste, J-M; Piton, N; Bubenheim, M; Melki, J; Wurtz, A; Peillon, C

    2017-05-01

    To report the results of minimally invasive surgery in patients with stage I or II thymoma in the Masaoka classification. The reference technique is partial or complete thymectomy by sternotonomy. A retrospective single-center study of a prospective database including all cases of thymoma operated from April 2009 to February 2015 by minimally invasive techniques: either videosurgery (VATS) or robot-assisted surgery (RATS). The surgical technique, type of resection, length of hospital stay, postoperative complications and recurrences were analysed. Our series consisted of 22 patients (15 women and 7 men). The average age was 53 years. Myasthenia gravis was present in 12 patients. Eight patients were operated on by VATS and 14 patiens by RATS. There were no conversions to sternotomy and no perioperative deaths. The mean operating time was 92min for VATS and 137min for RATS (P<0.001). The average hospital stay was 5 days. The mean weight of the specimen for the VATS group was 13.2 and 45.7mg for the RATS group. Twelve patients were classified Masaoka stage I and 10 were stage II. According to the WHO classification there were 7 patients type A, 5 type AB, 4 type B1, 4 type B2 4 and 2 type B3. As proposed by the Group ITMIG-IASLC in 2015 all patients corresponded to group I. The mean follow-up period was 36 months. We noted 3 major perioperative complications according to the Clavien-Dindo classification: one pneumonia, one phrenic nerve paralysis and one recurrent laryngeal nerve palsy. We observed one case of local recurrence at 22 months. Following surgery 4 patients were treated with radiotherapy and 2 patients with chemotherapy. The minimally invasive route is safe, relatively atraumatic and may be incorporated in the therapeutic arsenal for the treatment of Masaoka stage I and II thymoma as an alternative to conventional sternotomy. RATS and VATS are two minimally invasive techniques and the results in the short and medium term are

  13. The Influence of Robotic Assistance on Reducing Neuromuscular Effort and Fatigue during Extravehicular Activity Glove Use

    Science.gov (United States)

    Madden, Kaci E.; Deshpande, Ashish D.; Peters, Benjamin J.; Rogers, Jonathan M.; Laske, Evan A.; McBryan, Emily R.

    2017-01-01

    grasp-assist device that can improve astronaut performance and reduce the risk of injury by offsetting neuromuscular effort. Modifications to the experimental protocol are needed, however, to improve the outcome of the neuromuscular fatigue metrics and determine the effectiveness of SSRG in increasing astronaut endurance. Nevertheless, these findings will improve the understanding of astronaut-spacesuit interaction and provide direction toward designing improved spacesuit gloves and robotic-assist devices, like the SSRG.

  14. Robot-assisted 3D-TRUS guided prostate brachytherapy: System integration and validation

    International Nuclear Information System (INIS)

    Wei Zhouping; Wan Gang; Gardi, Lori; Mills, Gregory; Downey, Donal; Fenster, Aaron

    2004-01-01

    Current transperineal prostate brachytherapy uses transrectal ultrasound (TRUS) guidance and a template at a fixed position to guide needles along parallel trajectories. However, pubic arch interference (PAI) with the implant path obstructs part of the prostate from being targeted by the brachytherapy needles along parallel trajectories. To solve the PAI problem, some investigators have explored other insertion trajectories than parallel, i.e., oblique. However, parallel trajectory constraints in current brachytherapy procedure do not allow oblique insertion. In this paper, we describe a robot-assisted, three-dimensional (3D) TRUS guided approach to solve this problem. Our prototype consists of a commercial robot, and a 3D TRUS imaging system including an ultrasound machine, image acquisition apparatus and 3D TRUS image reconstruction, and display software. In our approach, we use the robot as a movable needle guide, i.e., the robot positions the needle before insertion, but the physician inserts the needle into the patient's prostate. In a later phase of our work, we will include robot insertion. By unifying the robot, ultrasound transducer, and the 3D TRUS image coordinate systems, the position of the template hole can be accurately related to 3D TRUS image coordinate system, allowing accurate and consistent insertion of the needle via the template hole into the targeted position in the prostate. The unification of the various coordinate systems includes two steps, i.e., 3D image calibration and robot calibration. Our testing of the system showed that the needle placement accuracy of the robot system at the 'patient's' skin position was 0.15 mm±0.06 mm, and the mean needle angulation error was 0.07 deg. . The fiducial localization error (FLE) in localizing the intersections of the nylon strings for image calibration was 0.13 mm, and the FLE in localizing the divots for robot calibration was 0.37 mm. The fiducial registration error for image calibration was 0

  15. Design and performance evaluation of collision protection-based safety operation for a haptic robot-assisted catheter operating system.

    Science.gov (United States)

    Zhang, Linshuai; Guo, Shuxiang; Yu, Huadong; Song, Yu; Tamiya, Takashi; Hirata, Hideyuki; Ishihara, Hidenori

    2018-02-23

    The robot-assisted catheter system can increase operating distance thus preventing the exposure radiation of the surgeon to X-ray for endovascular catheterization. However, few designs have considered the collision protection between the catheter tip and the vessel wall. This paper presents a novel catheter operating system based on tissue protection to prevent vessel puncture caused by collision. The integrated haptic interface not only allows the operator to feel the real force feedback, but also combines with the newly proposed collision protection mechanism (CPM) to mitigate the collision trauma. The CPM can release the catheter quickly when the measured force exceeds a certain threshold, so as to avoid the vessel puncture. A significant advantage is that the proposed mechanism can adjust the protection threshold in real time by the current according to the actual characteristics of the blood vessel. To verify the effectiveness of the tissue protection by the system, the evaluation experiments in vitro were carried out. The results show that the further collision damage can be effectively prevented by the CPM, which implies the realization of relative safe catheterization. This research provides some insights into the functional improvements of safe and reliable robot-assisted catheter systems.

  16. Kinematic measures for upper limb robot-assisted therapy following stroke and correlations with clinical outcome measures: A review.

    Science.gov (United States)

    Tran, Vi Do; Dario, Paolo; Mazzoleni, Stefano

    2018-03-01

    This review classifies the kinematic measures used to evaluate post-stroke motor impairment following upper limb robot-assisted rehabilitation and investigates their correlations with clinical outcome measures. An online literature search was carried out in PubMed, MEDLINE, Scopus and IEEE-Xplore databases. Kinematic parameters mentioned in the studies included were categorized into the International Classification of Functioning, Disability and Health (ICF) domains. The correlations between these parameters and the clinical scales were summarized. Forty-nine kinematic parameters were identified from 67 articles involving 1750 patients. The most frequently used parameters were: movement speed, movement accuracy, peak speed, number of speed peaks, and movement distance and duration. According to the ICF domains, 44 kinematic parameters were categorized into Body Functions and Structure, 5 into Activities and no parameters were categorized into Participation and Personal and Environmental Factors. Thirteen articles investigated the correlations between kinematic parameters and clinical outcome measures. Some kinematic measures showed a significant correlation coefficient with clinical scores, but most were weak or moderate. The proposed classification of kinematic measures into ICF domains and their correlations with clinical scales could contribute to identifying the most relevant ones for an integrated assessment of upper limb robot-assisted rehabilitation treatments following stroke. Increasing the assessment frequency by means of kinematic parameters could optimize clinical assessment procedures and enhance the effectiveness of rehabilitation treatments. Copyright © 2018 IPEM. Published by Elsevier Ltd. All rights reserved.

  17. Robotic-assisted Heller myotomy versus laparoscopic Heller myotomy for the treatment of esophageal achalasia: a case-control study.

    Science.gov (United States)

    Sánchez, Alexis; Rodríguez, Omaira; Nakhal, Elias; Davila, Hugo; Valero, Rair; Sánchez, Renata; Pena, Romina; Visconti, Maria F

    2012-09-01

    Minimally invasive surgery has become the gold standard for the treatment of achalasia. The incorporation of robotic technology can improve many limitations of laparoscopic surgery, through, for example, the availability of three-dimensional vision, increasing the degrees of movement, avoiding the fulcrum effect and optimizing ergonomics. The aim of this study was to compare robotic-assisted laparoscopic Heller myotomy (RAHM) with laparoscopic Heller myotomy (LHM) in terms of efficacy and safety. Thirty-one patients with diagnosis of achalasia confirmed by esophagogram and manometry were included. Dysphagia and weight loss were the main complaints in both groups. 18 patients were treated with LHM and 13 patients with RAHM. There was no difference in mean operative time (76 ± 13 vs. 79 ± 20 min; P = 0.73). Intraoperative complications were less frequent in the robotic-assisted procedures (5.5% vs. 0%); however, this was a non-significant difference. 94.5-100% of patients had relief of their symptoms. We conclude that RAHM is a safe and effective procedure. The operative time is no longer than in LHM, but it is necessary to evaluate the technique in randomized clinical trials to determine its advantages in terms of intraoperative complications.

  18. Rare Case of an Epithelial Cyst in an Intrapancreatic Accessory Spleen Treated by Robot-Assisted Spleen Preserving Distal Pancreatectomy.

    Science.gov (United States)

    van Dijck, Willemijn P M; Groot, Vincent P; Brosens, Lodewijk A A; Hagendoorn, Jeroen; Rinkes, Inne H M Borel; van Leeuwen, Maarten S; Molenaar, I Quintus

    2016-01-01

    Epithelial cyst in an intrapancreatic accessory spleen (ECIPAS) is exceedingly rare with only 57 cases reported since the first publication in 1980. Comprehensive clinical and diagnostic features remain to be clarified. We present a case of ECIPAS in a 21-year-old Philippine woman who was admitted with right upper quadrant abdominal pain. A cystic lesion in the pancreatic tail was discovered and evaluated by computed tomography and magnetic resonance images. Based on clinical and radiological features a solid pseudopapillary neoplasm was suspected. The patient underwent robot-assisted spleen preserving distal pancreatectomy. Pathological evaluation revealed a 26 mm intrapancreatic accessory spleen with a 16 mm cyst, lined by multilayered epithelium in the tail of the pancreas. The postoperative course was uneventful. Differentiating ECIPAS from (pre)malignant cystic pancreatic neoplasms based on clinical and radiological features remains difficult. When typical radiological signs can be combined with scintigraphy using Technetium-99m labelled colloid or Technetium-99m labelled erythrocytes, which can identify the solid component of the lesion as splenic tissue, it should be possible to make the right diagnosis noninvasively. When pancreatectomy is inevitable due to symptoms or patient preference, minimally invasive laparoscopic or robot-assisted spleen preserving distal pancreatectomy should be considered.

  19. Rare Case of an Epithelial Cyst in an Intrapancreatic Accessory Spleen Treated by Robot-Assisted Spleen Preserving Distal Pancreatectomy

    Directory of Open Access Journals (Sweden)

    Willemijn P. M. van Dijck

    2016-01-01

    Full Text Available Epithelial cyst in an intrapancreatic accessory spleen (ECIPAS is exceedingly rare with only 57 cases reported since the first publication in 1980. Comprehensive clinical and diagnostic features remain to be clarified. We present a case of ECIPAS in a 21-year-old Philippine woman who was admitted with right upper quadrant abdominal pain. A cystic lesion in the pancreatic tail was discovered and evaluated by computed tomography and magnetic resonance images. Based on clinical and radiological features a solid pseudopapillary neoplasm was suspected. The patient underwent robot-assisted spleen preserving distal pancreatectomy. Pathological evaluation revealed a 26 mm intrapancreatic accessory spleen with a 16 mm cyst, lined by multilayered epithelium in the tail of the pancreas. The postoperative course was uneventful. Differentiating ECIPAS from (premalignant cystic pancreatic neoplasms based on clinical and radiological features remains difficult. When typical radiological signs can be combined with scintigraphy using Technetium-99m labelled colloid or Technetium-99m labelled erythrocytes, which can identify the solid component of the lesion as splenic tissue, it should be possible to make the right diagnosis noninvasively. When pancreatectomy is inevitable due to symptoms or patient preference, minimally invasive laparoscopic or robot-assisted spleen preserving distal pancreatectomy should be considered.

  20. Hemorrhagic versus ischemic stroke: Who can best benefit from blended conventional physiotherapy with robotic-assisted gait therapy?

    Science.gov (United States)

    Dierick, Frédéric; Dehas, Mélanie; Isambert, Jean-Luc; Injeyan, Soizic; Bouché, Anne-France; Bleyenheuft, Yannick; Portnoy, Sigal

    2017-01-01

    Contrary to common belief of clinicians that hemorrhagic stroke survivors have better functional prognoses than ischemic, recent studies show that ischemic survivors could experience similar or even better functional improvements. However, the influence of stroke subtype on gait and posture outcomes following an intervention blending conventional physiotherapy with robotic-assisted gait therapy is missing. This study compared gait and posture outcome measures between ambulatory hemorrhagic patients and ischemic patients, who received a similar 4 weeks' intervention blending a conventional bottom-up physiotherapy approach and an exoskeleton top-down robotic-assisted gait training (RAGT) approach with Lokomat. Forty adult hemiparetic stroke inpatient subjects were recruited: 20 hemorrhagic and 20 ischemic, matched by age, gender, side of hemisphere lesion, stroke severity, and locomotor impairments. Functional Ambulation Category, Postural Assessment Scale for Stroke, Tinetti Performance Oriented Mobility Assessment, 6 Minutes Walk Test, Timed Up and Go and 10-Meter Walk Test were performed before and after a 4-week long intervention. Functional gains were calculated for all tests. Hemorrhagic and ischemic subjects showed significant improvements in Functional Ambulation Category (Pbenefits from the same type, length and frequency of blended conventional physiotherapy and RAGT protocol. The use of intensive treatment plans blending top-down physiotherapy and bottom-up robotic approaches is promising for post-stroke rehabilitation.

  1. Accuracy and efficacy of percutaneous biopsy and ablation using robotic assistance under computed tomography guidance: a phantom study

    International Nuclear Information System (INIS)

    Koethe, Yilun; Xu, Sheng; Velusamy, Gnanasekar; Wood, Bradford J.; Venkatesan, Aradhana M.

    2014-01-01

    To compare the accuracy of a robotic interventional radiologist (IR) assistance platform with a standard freehand technique for computed-tomography (CT)-guided biopsy and simulated radiofrequency ablation (RFA). The accuracy of freehand single-pass needle insertions into abdominal phantoms was compared with insertions facilitated with the use of a robotic assistance platform (n = 20 each). Post-procedural CTs were analysed for needle placement error. Percutaneous RFA was simulated by sequentially placing five 17-gauge needle introducers into 5-cm diameter masses (n = 5) embedded within an abdominal phantom. Simulated ablations were planned based on pre-procedural CT, before multi-probe placement was executed freehand. Multi-probe placement was then performed on the same 5-cm mass using the ablation planning software and robotic assistance. Post-procedural CTs were analysed to determine the percentage of untreated residual target. Mean needle tip-to-target errors were reduced with use of the IR assistance platform (both P < 0.0001). Reduced percentage residual tumour was observed with treatment planning (P = 0.02). Improved needle accuracy and optimised probe geometry are observed during simulated CT-guided biopsy and percutaneous ablation with use of a robotic IR assistance platform. This technology may be useful for clinical CT-guided biopsy and RFA, when accuracy may have an impact on outcome. (orig.)

  2. A MR-conditional High-torque Pneumatic Stepper Motor for MRI-guided and Robot-assisted Intervention

    Science.gov (United States)

    Chen, Yue; Kwok, Ka-Wai; Tse, Zion Tsz Ho

    2015-01-01

    Magnetic Resonance Imaging allows for visualizing detailed pathological and morphological changes of soft tissue. This increasingly attracts attention on MRI-guided intervention; hence, MR-conditional actuations have been widely investigated for development of image-guided and robot-assisted surgical devices under the MRI. This paper presents a simple design of MR-conditional stepper motor which can provide precise and high-torque actuation without adversely affecting the MR image quality. This stepper motor consists of two MR-conditional pneumatic cylinders and the corresponding supporting structures. Alternating the pressurized air can drive the motor to rotate each step in 3.6° with the motor coupled to a planetary gearbox. Experimental studies were conducted to validate its dynamics performance. Maximum 800mNm output torque can be achieved. The motor accuracy independently varied by two factors: motor operating speed and step size, was also investigated. The motor was tested within a Siemens 3T MRI scanner. The image artifact and the signal-to-noise ratio (SNR) were evaluated in order to study its MRI compliancy. The results show that the presented pneumatic stepper motor generated 2.35% SNR reduction in MR images and no observable artifact was presented besides the motor body itself. The proposed motor test also demonstrates a standard to evaluate the motor capability for later incorporation with motorized devices used in robot-assisted surgery under MRI. PMID:24957635

  3. [Individual learning curve for radical robot-assisted prostatectomy based on the example of three professionals working in one clinic].

    Science.gov (United States)

    Rasner, P I; Pushkar', D Iu; Kolontarev, K B; Kotenkov, D V

    2014-01-01

    The appearance of new surgical technique always requires evaluation of its effectiveness and ease of acquisition. A comparative study of the results of the first three series of successive robot-assisted radical prostatectomy (RARP) performed on at time by three surgeons, was conducted. The series consisted of 40 procedures, and were divided into 4 groups of 10 operations for the analysis. When comparing data, statistically significant improvement of intra- and postoperative performance in each series was revealed, with increase in the number of operations performed, and in each subsequent series compared with the preceding one. We recommend to perform the planned conversion at the first operation. In our study, previous laparoscopic experience did not provide any significant advantages in the acquisition of robot-assisted technology. To characterize the individual learning curve, we recommend the use of the number of operations that the surgeon looked in the life-surgery regimen and/or in which he participated as an assistant before his own surgical activity, as well as the indicator "technical defect". In addition to the term "individual learning curve", we propose to introduce the terms "surgeon's individual training phase", and "clinic's learning curve".

  4. Accuracy and efficacy of percutaneous biopsy and ablation using robotic assistance under computed tomography guidance: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Koethe, Yilun [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States); Duke University School of Medicine, Durham, NC (United States); Xu, Sheng [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); Velusamy, Gnanasekar [Perfint Healthcare Pvt. Ltd., Chennai (India); Wood, Bradford J. [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States); Venkatesan, Aradhana M. [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States)

    2014-03-15

    To compare the accuracy of a robotic interventional radiologist (IR) assistance platform with a standard freehand technique for computed-tomography (CT)-guided biopsy and simulated radiofrequency ablation (RFA). The accuracy of freehand single-pass needle insertions into abdominal phantoms was compared with insertions facilitated with the use of a robotic assistance platform (n = 20 each). Post-procedural CTs were analysed for needle placement error. Percutaneous RFA was simulated by sequentially placing five 17-gauge needle introducers into 5-cm diameter masses (n = 5) embedded within an abdominal phantom. Simulated ablations were planned based on pre-procedural CT, before multi-probe placement was executed freehand. Multi-probe placement was then performed on the same 5-cm mass using the ablation planning software and robotic assistance. Post-procedural CTs were analysed to determine the percentage of untreated residual target. Mean needle tip-to-target errors were reduced with use of the IR assistance platform (both P < 0.0001). Reduced percentage residual tumour was observed with treatment planning (P = 0.02). Improved needle accuracy and optimised probe geometry are observed during simulated CT-guided biopsy and percutaneous ablation with use of a robotic IR assistance platform. This technology may be useful for clinical CT-guided biopsy and RFA, when accuracy may have an impact on outcome. (orig.)

  5. Structural brain changes after traditional and robot-assisted multi-domain cognitive training in community-dwelling healthy elderly.

    Directory of Open Access Journals (Sweden)

    Geon Ha Kim

    Full Text Available The purpose of this study was to investigate if multi-domain cognitive training, especially robot-assisted training, alters cortical thickness in the brains of elderly participants. A controlled trial was conducted with 85 volunteers without cognitive impairment who were 60 years old or older. Participants were first randomized into two groups. One group consisted of 48 participants who would receive cognitive training and 37 who would not receive training. The cognitive training group was randomly divided into two groups, 24 who received traditional cognitive training and 24 who received robot-assisted cognitive training. The training for both groups consisted of daily 90-min-session, five days a week for a total of 12 weeks. The primary outcome was the changes in cortical thickness. When compared to the control group, both groups who underwent cognitive training demonstrated attenuation of age related cortical thinning in the frontotemporal association cortices. When the robot and the traditional interventions were directly compared, the robot group showed less cortical thinning in the anterior cingulate cortices. Our results suggest that cognitive training can mitigate age-associated structural brain changes in the elderly.ClnicalTrials.gov NCT01596205.

  6. Effects of robot-assisted training on upper limb functional recovery during the rehabilitation of poststroke patients.

    Science.gov (United States)

    Daunoraviciene, Kristina; Adomaviciene, Ausra; Grigonyte, Agne; Griškevičius, Julius; Juocevicius, Alvydas

    2018-05-18

    The study aims to determine the effectiveness of robot-assisted training in the recovery of stroke-affected arms using an exoskeleton robot Armeo Spring. To identify the effect of robot training on functional recovery of the arm. A total of 34 stroke patients were divided into either an experimental group (EG; n= 17) or a control group (n= 17). EG was also trained to use the Armeo Spring during occupational therapy. Both groups were clinically assessed before and after treatment. Statistical comparison methods (i.e. one-tailed t-tests for differences between two independent means and the simplest test) were conducted to compare motor recovery using robot-assisted training or conventional therapy. Patients assigned to the EG showed a statistically significant improvement in upper extremity motor function when compared to the CG by FIM (Peffect in the EG and CG was meaningful for shoulder and elbow kinematic parameters. The findings show the benefits of robot therapy in two areas of functional recovery. Task-oriented robotic training in rehabilitation setting facilitates recovery not only of the motor function of the paretic arm but also of the cognitive abilities in stroke patients.

  7. Exploring the effects of dimensionality reduction in deep networks for force estimation in robotic-assisted surgery

    Science.gov (United States)

    Aviles, Angelica I.; Alsaleh, Samar; Sobrevilla, Pilar; Casals, Alicia

    2016-03-01

    Robotic-Assisted Surgery approach overcomes the limitations of the traditional laparoscopic and open surgeries. However, one of its major limitations is the lack of force feedback. Since there is no direct interaction between the surgeon and the tissue, there is no way of knowing how much force the surgeon is applying which can result in irreversible injuries. The use of force sensors is not practical since they impose different constraints. Thus, we make use of a neuro-visual approach to estimate the applied forces, in which the 3D shape recovery together with the geometry of motion are used as input to a deep network based on LSTM-RNN architecture. When deep networks are used in real time, pre-processing of data is a key factor to reduce complexity and improve the network performance. A common pre-processing step is dimensionality reduction which attempts to eliminate redundant and insignificant information by selecting a subset of relevant features to use in model construction. In this work, we show the effects of dimensionality reduction in a real-time application: estimating the applied force in Robotic-Assisted Surgeries. According to the results, we demonstrated positive effects of doing dimensionality reduction on deep networks including: faster training, improved network performance, and overfitting prevention. We also show a significant accuracy improvement, ranging from about 33% to 86%, over existing approaches related to force estimation.

  8. Resident education in robotic-assisted vertical sleeve gastrectomy: outcomes and cost-analysis of 411 consecutive cases.

    Science.gov (United States)

    Ecker, Brett L; Maduka, Richard; Ramdon, Andre; Dempsey, Daniel T; Dumon, Kristoffel R; Williams, Noel N

    2016-02-01

    Robotic technology is increasingly prevalent in bariatric surgery, yet there are national deficiencies in exposure of surgical residents to robotic techniques. The purpose of this study is to accurately characterize the perioperative outcomes of a resident teaching model using the robotic-assisted sleeve gastrectomy. University Hospital. We identified 411 consecutive patients who underwent robotic sleeve gastrectomy at our institution from a prospectively maintained administrative database. Perioperative morbidity, operative time, and supply cost of the procedure were analyzed. Mean operative time was 96.4±24.9 minutes; mean robot usage time was 63.9 minutes (range 30.0-122.0 min). Ninety-day morbidities included reoperation (0.72%), major bleeding complications (0.48%), staple line leak (0.24%), stricture (0.97%), need for blood transfusion (3.86%), surgical site infection (1.69%), deep vein thrombosis (0.48%), and pulmonary embolism (0.48%). Mortality was nil. The resident cohort achieved operative time plateaus after five consecutive cases. Subset analysis for fiscal year 2014 demonstrated significantly increased supply cost for robotic sleeve gastrectomy compared with its laparoscopic equivalent. Robotic-assisted sleeve gastrectomy can be instituted as a model for resident robotic education with rates of morbidity and operative times equivalent to historical laparoscopic controls. The robot's enhanced ergonomics and its opportunity for resident education must be weighed against its increased supply cost. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  9. Brain-state dependent robotic reaching movement with a multi-joint arm exoskeleton: combining brain-machine interfacing and robotic rehabilitation

    Directory of Open Access Journals (Sweden)

    Daniel eBrauchle

    2015-10-01

    Full Text Available While robot-assisted arm and hand training after stroke allows for intensive task-oriented practice, it has provided only limited additional benefit over dose-matched physiotherapy up to now. These rehabilitation devices are possibly too supportive during the exercises. Neurophysiological signals might be one way of avoiding slacking and providing robotic support only when the brain is particularly responsive to peripheral input.We tested the feasibility of three-dimensional robotic assistance for reach-to-grasp movements with a multi-joint exoskeleton during motor imagery-related desynchronization of sensorimotor oscillations in the β-band only. We also registered task-related network changes of cortical functional connectivity by electroencephalography via the imaginary part of the coherence function.Healthy subjects and stroke survivors showed similar patterns – but different aptitudes – of controlling the robotic movement. All participants in this pilot study with nine healthy subjects and two stroke patients achieved their maximum performance during the early stages of the task. Robotic control was significantly higher and less variable when proprioceptive feedback was provided in addition to visual feedback, i.e. when the orthosis was actually attached to the subject’s arm during the task. A distributed cortical network of task-related coherent activity in the θ-band showed significant differences between healthy subjects and stroke patients as well as between early and late periods of the task.Brain-robot interfaces may successfully link three-dimensional robotic training to the participants’ efforts and allow for task-oriented practice of activities of daily living with a physiologically controlled multi-joint exoskeleton. Changes of cortical physiology during the task might also help to make subject-specific adjustments of task difficulty and guide adjunct interventions to facilitate motor learning for functional restoration.

  10. Robotic-Assisted Minimally Invasive Surgery for Gynecologic and Urologic Oncology

    Science.gov (United States)

    2010-01-01

    conventional laparoscopy surgery and allows for tremor-free manipulation. The main disadvantages of use of the robotic device are the costs including instrument costs ($2.6 million in US dollars), cost per use ($200 per use), the costs associated with training surgeons and operating room personnel, and the lack of tactile feedback, with the trade-off being increased visual feedback. Research Questions For endometrial and cervical cancers, 1. What is the effectiveness of the Da Vinci Surgical System vs. laparoscopy and laparotomy for women undergoing any hysterectomy for the surgical treatment and management of their endometrial and cervical cancers? 2. What are the incremental costs of the Da Vinci Surgical System vs. laparoscopy and laparotomy for women undergoing any hysterectomy for the surgical treatment and management of their endometrial and cervical cancers? For prostate cancer, 3. What is the effectiveness of robotically-assisted radical prostatectomy using the Da Vinci Surgical System vs. laparoscopic radical prostatectomy and retropubic radical prostatectomy for the surgical treatment and management of prostate cancer? 4. What are the incremental costs of robotically-assisted radical prostatectomy using the Da Vinci Surgical System vs. laparoscopic radical prostatectomy and retropubic radical prostatectomy for the surgical treatment and management of prostate cancer? Research Methods Literature Search Search Strategy A literature search was performed on May 12, 2010 using OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, OVID EMBASE, Wiley Cochrane, CINAHL, Centre for Reviews and Dissemination/International Agency for Health Technology Assessment for studies published from January 1, 2000 until May 12, 2010. Abstracts were reviewed by a single reviewer and, for those studies meeting the eligibility criteria, full-text articles were obtained. Reference lists were also examined for any additional relevant studies not identified through the search

  11. ROBOT-ASSISTED RADICAL PROSTATECTOMY: ANALYSIS OF THE FIRST 80 CASES

    Directory of Open Access Journals (Sweden)

    D. Yu. Pushkar

    2010-01-01

    Full Text Available Background. As a common disease, prostate cancer (PC has taken now first place among all malignancies in many countries of the world.The authors have analyzed the results of their series of robot-assisted radical laparoscopic prostatectomy (RALP in patients with PC. They also present a number of surgical techniques that may be useful for novice surgeons. Materials and methods. In November 2008 to November 2009, the Department of Urology, Moscow State University of Medicine and Dentistry, performed 80 RALPs using the da Vinci S surgical robotic system. The patients’ mean age was 63.7 (49–71 years; the mean blood level of total prostate-specific antigen was 6.1 (2.1–20.84 ng/ml; the mean prostate volume was 44 (18–94 cm3, as evidenced by transrectal ultrasound study. The authors analyzed the following indicators: operating time, degree of blood loss, conversion of surgical intervention,degrees of intra- and postoperative complications, and oncological and functional results. Results. In our series, RALP was performed without preserving neurovascular bundles or by using a nerve-sparing procedure in 66 (82.5% and 14 (17.5%, respectively; 22 (27.5% patients underwent lymphadenectomy. The average length of hospital stay was 7 (4–21 days; the mean time of urethral catheter removal was 10 (6–21 days postoperatively. The mean time of surgical intervention was 174 (121–276 min. Mean blood loss was 248 (35–1950 ml. Postmortem study revealed a positive surgical margin in 19 (24% cases and tumor invasion into the seminal vesicles in 5 (6% patients. Stages pT2 and pT3 were found in 56 (70% and 24 (30%, respectively; total Gleason scores were 6 (3+3, 7 (3+4, 7 (4+3, 8 (4+4 in 38 (47.5%, 35 (43.75%, 5 (6.25%, and 2 (2.5% patients, respectively. Among 34 patients examined 3 months after RALP, 28 (82.4% patients completely retained urine; 5 (14.7% applied not more than a pad a day. In patients with preserved erectile function, the

  12. Development and validation of surgical training tool: cystectomy assessment and surgical evaluation (CASE) for robot-assisted radical cystectomy for men.

    Science.gov (United States)

    Hussein, Ahmed A; Sexton, Kevin J; May, Paul R; Meng, Maxwell V; Hosseini, Abolfazl; Eun, Daniel D; Daneshmand, Siamak; Bochner, Bernard H; Peabody, James O; Abaza, Ronney; Skinner, Eila C; Hautmann, Richard E; Guru, Khurshid A

    2018-04-13

    We aimed to develop a structured scoring tool: cystectomy assessment and surgical evaluation (CASE) that objectively measures and quantifies performance during robot-assisted radical cystectomy (RARC) for men. A multinational 10-surgeon expert panel collaborated towards development and validation of CASE. The critical steps of RARC in men were deconstructed into nine key domains, each assessed by five anchors. Content validation was done utilizing the Delphi methodology. Each anchor was assessed in terms of context, score concordance, and clarity. The content validity index (CVI) was calculated for each aspect. A CVI ≥ 0.75 represented consensus, and this statement was removed from the next round. This process was repeated until consensus was achieved for all statements. CASE was used to assess de-identified videos of RARC to determine reliability and construct validity. Linearly weighted percent agreement was used to assess inter-rater reliability (IRR). A logit model for odds ratio (OR) was used to assess construct validation. The expert panel reached consensus on CASE after four rounds. The final eight domains of the CASE included: pelvic lymph node dissection, development of the peri-ureteral space, lateral pelvic space, anterior rectal space, control of the vascular pedicle, anterior vesical space, control of the dorsal venous complex, and apical dissection. IRR > 0.6 was achieved for all eight domains. Experts outperformed trainees across all domains. We developed and validated a reliable structured, procedure-specific tool for objective evaluation of surgical performance during RARC. CASE may help differentiate novice from expert performances.

  13. Assessing the Impact of Surgeon Experience on Urinary Continence Recovery After Robot-Assisted Radical Prostatectomy: Results of Four High-Volume Surgeons.

    Science.gov (United States)

    Fossati, Nicola; Di Trapani, Ettore; Gandaglia, Giorgio; Dell'Oglio, Paolo; Umari, Paolo; Buffi, Nicolò Maria; Guazzoni, Giorgio; Mottrie, Alexander; Gaboardi, Franco; Montorsi, Francesco; Briganti, Alberto; Suardi, Nazareno

    2017-09-01

    To test the impact of surgeon experience on urinary continence (UC) recovery after robot-assisted radical prostatectomy (RARP). The study included 1477 consecutive patients treated with RARP by four surgeons between 2006 and 2014. UC recovery was defined as being completely dry over a 24-hour period at follow-up. Surgeon experience was coded as the total number of RARP performed by the surgeon before the patient's operation. Multivariable analysis tested the association between surgeon experience and UC recovery. Covariates consisted of patient age, Charlson comorbidity index, preoperative International Index of Erectile Function-Erectile Function domain (IIEF-EF), nerve-sparing surgery (none vs unilateral vs bilateral), and preoperative risk groups (low- vs intermediate- vs high risk). The number of cases performed by each surgeon was 541, 413, 411, and 112, respectively. Median follow-up was 24 months (inter-quartile range: 18, 40). The UC recovery rate at 1 year after surgery was 82%. At multivariable analyses, surgeon experience represented an independent predictor of UC recovery (hazard ratio: 1.02, p < 0.001). The surgical learning curve was similar among surgeons, moving linearly from ∼60% of UC rate at the initial cases to almost 90% after more than 400 procedures. In patients undergoing RARP, surgeon experience is a significant predictor of UC recovery. The surgical learning curve of UC recovery does not reach a plateau even after more than 100 cases, suggesting a continuous improvement of the surgical technique. These findings deserve attention for patient counseling and future comparative studies evaluating functional outcomes after RARP.

  14. Combination of robot-assisted and conventional body-weight-supported treadmill training improves gait in persons with multiple sclerosis: a pilot study.

    Science.gov (United States)

    Ruiz, Jennifer; Labas, Michele P; Triche, Elizabeth W; Lo, Albert C

    2013-12-01

    The majority of persons with multiple sclerosis (MS) experience problems with gait, which they characterize as highly disabling impairments that adversely impact their quality of life. Thus, it is crucial to develop effective therapies to improve mobility for these individuals. The purpose of this study was to determine whether combination gait training, using robot-assisted treadmill training followed by conventional body-weight-supported treadmill training within the same session, improved gait and balance in individuals with MS. This study tested combination gait training in 7 persons with MS. The participants were randomized into the immediate therapy group (IT group) or the delayed therapy group (DT group). In phase I of the trial, the IT group received treatment while the DT group served as a concurrent comparison group. In phase II of the trial, the DT group received treatment identical to the treatment received by the IT group in phase I. Outcome measures included the 6-Minute Walk Test (6MWT), the Timed 25-Foot Walk Test, velocity, cadence, and the Functional Reach Test (FRT). Nonparametric statistical techniques were used for analysis. Combination gait training resulted in significantly greater improvements in the 6MWT for the IT group (median change = +59 m) compared with Phase I DT group (median change = -8 m) (P = 0.08) and FRT (median change = +3.3 cm in IT vs -0.8 cm in the DT group phase I; P = 0.03). Significant overall pre-post improvements following combination gait training were found in 6MWT (+32 m; P = 0.02) and FRT (+3.3 cm; P = 0.06) for IT and Phase II DT groups combined. Combination of robot with body-weight-supported treadmill training gait training is feasible and improved 6MWT and FRT distances in persons with MS.Video Abstract available (see Video, Supplemental Digital Content 1, http://links.lww.com/JNPT/A62) for more insights from the authors.

  15. Effect of visual distraction and auditory feedback on patient effort during robot-assisted movement training after stroke.

    Science.gov (United States)

    Secoli, Riccardo; Milot, Marie-Helene; Rosati, Giulio; Reinkensmeyer, David J

    2011-04-23

    Practicing arm and gait movements with robotic assistance after neurologic injury can help patients improve their movement ability, but patients sometimes reduce their effort during training in response to the assistance. Reduced effort has been hypothesized to diminish clinical outcomes of robotic training. To better understand patient slacking, we studied the role of visual distraction and auditory feedback in modulating patient effort during a common robot-assisted tracking task. Fourteen participants with chronic left hemiparesis from stroke, five control participants with chronic right hemiparesis and fourteen non-impaired healthy control participants, tracked a visual target with their arms while receiving adaptive assistance from a robotic arm exoskeleton. We compared four practice conditions: the baseline tracking task alone; tracking while also performing a visual distracter task; tracking with the visual distracter and sound feedback; and tracking with sound feedback. For the distracter task, symbols were randomly displayed in the corners of the computer screen, and the participants were instructed to click a mouse button when a target symbol appeared. The sound feedback consisted of a repeating beep, with the frequency of repetition made to increase with increasing tracking error. Participants with stroke halved their effort and doubled their tracking error when performing the visual distracter task with their left hemiparetic arm. With sound feedback, however, these participants increased their effort and decreased their tracking error close to their baseline levels, while also performing the distracter task successfully. These effects were significantly smaller for the participants who used their non-paretic arm and for the participants without stroke. Visual distraction decreased participants effort during a standard robot-assisted movement training task. This effect was greater for the hemiparetic arm, suggesting that the increased demands associated

  16. Effect of visual distraction and auditory feedback on patient effort during robot-assisted movement training after stroke

    Directory of Open Access Journals (Sweden)

    Reinkensmeyer David J

    2011-04-01

    Full Text Available Abstract Background Practicing arm and gait movements with robotic assistance after neurologic injury can help patients improve their movement ability, but patients sometimes reduce their effort during training in response to the assistance. Reduced effort has been hypothesized to diminish clinical outcomes of robotic training. To better understand patient slacking, we studied the role of visual distraction and auditory feedback in modulating patient effort during a common robot-assisted tracking task. Methods Fourteen participants with chronic left hemiparesis from stroke, five control participants with chronic right hemiparesis and fourteen non-impaired healthy control participants, tracked a visual target with their arms while receiving adaptive assistance from a robotic arm exoskeleton. We compared four practice conditions: the baseline tracking task alone; tracking while also performing a visual distracter task; tracking with the visual distracter and sound feedback; and tracking with sound feedback. For the distracter task, symbols were randomly displayed in the corners of the computer screen, and the participants were instructed to click a mouse button when a target symbol appeared. The sound feedback consisted of a repeating beep, with the frequency of repetition made to increase with increasing tracking error. Results Participants with stroke halved their effort and doubled their tracking error when performing the visual distracter task with their left hemiparetic arm. With sound feedback, however, these participants increased their effort and decreased their tracking error close to their baseline levels, while also performing the distracter task successfully. These effects were significantly smaller for the participants who used their non-paretic arm and for the participants without stroke. Conclusions Visual distraction decreased participants effort during a standard robot-assisted movement training task. This effect was greater for

  17. Videocirurgia colorretal com assistência robótica: o próximo passo? Robotic assisted colorrectal surgery

    Directory of Open Access Journals (Sweden)

    Sergio Eduardo Alonso Araujo

    2008-09-01

    Full Text Available O desenvolvimento de técnicas minimamente invasivas é um dos mais importantes avanços da cirurgia colorretal. A assistência robótica integra o arsenal de técnicas em cirurgia minimamente invasiva, e vem sendo aplicado em cirurgia colorretal por um restrito grupo de cirurgiões em alguns centros ao redor do mundo com resultados iniciais que merecem atenção. O objetivo do presente estudo é analisar os resultados do emprego da assistência robótica em videocirurgia colorretal. Dentre as vantagens associadas ao emprego de robôs em videocirurgia colorretal, figuram o incremento na precisão dos movimentos e a visão tridimensional. A experiência clínica é ainda pequena, e advém de uma série de casos e estudos comparativos com a videocirurgia colorretal sem assistência robótica com ainda pequeno número de casos. A dissecção pélvica com incremento da preservação autonômica parece ser a maior vantagem associada à assistência robótica em videocirurgia colorretal. Somente através do treinamento de um número mais representativo de cirurgiões colorretais, bem como com a expansão da experiência clínica será possível prever com maior precisão o papel da assistência robótica em videocirurgia colorretal.The development of minimally invasive surgical techniques represents an important aspect of modern surgical research. Robot-assisted minimally invasive colorectal surgery represents a way of assisting laparoscopic colorectal procedures. Robotic technology overcomes some of these limitations by successfully providing intuitive motion and enhanced precision and accuracy, in an environment that is much more ergonomic. A restrict number of surgeons in specialized centers around the world have been applying robotics. In this review, current evidence about different technologies and its place in colorectal surgery is evaluated. The feasibility of performing robot-assisted colorectal operations has been demonstrated though case

  18. Robotic-assisted Reconstruction of the Cervix and Vagina by Small Intestinal Submucosa Graft and Fusion of the Hemiuterus.

    Science.gov (United States)

    Zhang, Ying; Chen, Yisong; Hua, Keqin

    To describe our technique of robotic-assisted reconstruction of the cervix and vagina using a small intestinal submucosa (SIS) graft and fusion of the hemiuterus. A step-by-step explanation of the procedure using video. Congenital complete vaginal and cervical atresia is rare. Some patients have urinary system abnormality. No standardized surgical treatment guideline was available, and the performance varies for each patient. We performed a robotic-assisted reconstruction of the cervix and vagina using an SIS graft (Cook Medical, Bloomington, IN) and fusion of the hemiuterus for a 12-year-old girl from China diagnosed with congenital vaginal and cervical atresia (U4C4V4). She complained of severe abdominal periodic pain for 2 months. Mammary development and her serum sex hormone were within normal range. The patient has a single kidney. The diagnosis was made according to clinical characteristics, physical examination, and magnetic resonance imaging and classified using the European Society of Human Reproduction and Embryology /European Society for Gynaecological Endoscopy (ESHRE/ESGE) system. There was a hematometra of 7-cm diameter in her pelvis. We constructed a novel vagina by sharp and blunt separation and connected it to the uterine cavity. With the SIS graft, we reconstructed her cervix and vagina, and we fused the hemiuterus to make the uterine cavity spacious. The operating time was 260 minutes, and blood loss was 300 mL. She recovered well after the operation without any complications. After surgery, the patient has had normal menstruation without pain. She insists on wearing the vaginal mold 24 hours per day. The follow-up was 10 months. The length of the vagina was 9 cm and the width was 3 cm. Robotic-assisted reconstruction of the cervix and vagina using an SIS graft and fusion of the hemiuterus is feasible and safety. However, additional studies are required. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  19. Surgeons’ muscle load during robotic-assisted laparoscopy performed with a regular office chair and the preferred of two ergonomic chairs

    DEFF Research Database (Denmark)

    Dalager, T.; Jensen, P. T.; Winther, T. S.

    2018-01-01

    associated with poor ergonomics and musculoskeletal pain. The ergonomic condition in the robotic console is partially dependent upon the chair provided, which often is a regular office chair. Our study quantified and compared the muscular load during robotic-assisted laparoscopy using one of two custom built...

  20. Effects of Robot-assisted Gait Training Combined with Functional Electrical Stimulation on Recovery of Locomotor Mobility in Chronic Stroke Patients: A Randomized Controlled Trial.

    Science.gov (United States)

    Bae, Young-Hyeon; Ko, Young Jun; Chang, Won Hyuk; Lee, Ju Hyeok; Lee, Kyeong Bong; Park, Yoo Jung; Ha, Hyun Geun; Kim, Yun-Hee

    2014-12-01

    [Purpose] The purpose of the present study was to investigate the effects of robot-assisted gait training combined with functional electrical stimulation on locomotor recovery in patients with chronic stroke. [Subjects] The 20 subjects were randomly assigned into either an experimental group (n = 10) that received a combination of robot-assisted gait training and functional electrical stimulation on the ankle dorsiflexor of the affected side or a control group (n = 10) that received robot-assisted gait training only. [Methods] Both groups received the respective therapies for 30 min/day, 3 days/week for 5 weeks. The outcome was measured using the Modified Motor Assessment Scale (MMAS), Timed Up-and-Go Test (TUG), Berg Balance Scale (BBS), and gait parameters through gait analysis (Vicon 370 motion analysis system, Oxford Metrics Ltd., Oxford, UK). All the variables were measured before and after training. [Results] Step length and maximal knee extension were significantly greater than those before training in the experimental group only. Maximal Knee flexion showed a significant difference between the experimental and control groups. The MMAS, BBS, and TUG scores improved significantly after training compared with before training in both groups. [Conclusion] We suggest that the combination of robot-assisted gait training and functional electrical stimulation encourages patients to actively participate in training because it facilitates locomotor recovery without the risk of adverse effects.

  1. Test-retest reliability and four-week changes in cardiopulmonary fitness in stroke patients: evaluation using a robotics-assisted tilt table.

    Science.gov (United States)

    Saengsuwan, Jittima; Berger, Lucia; Schuster-Amft, Corina; Nef, Tobias; Hunt, Kenneth J

    2016-09-06

    Exercise testing devices for evaluating cardiopulmonary fitness in patients with severe disability after stroke are lacking, but we have adapted a robotics-assisted tilt table (RATT) for cardiopulmonary exercise testing (CPET). Using the RATT in a sample of patients after stroke, this study aimed to investigate test-retest reliability and repeatability of CPET and to prospectively investigate changes in cardiopulmonary outcomes over a period of four weeks. Stroke patients with all degrees of disability underwent 3 separate CPET sessions: 2 tests at baseline (TB1 and TB2) and 1 test at follow up (TF). TB1 and TB2 were at least 24 h apart. TB2 and TF were 4 weeks apart. A RATT equipped with force sensors in the thigh cuffs, a work rate estimation algorithm and a real-time visual feedback system was used to guide the patients' exercise work rate during CPET. Test-retest reliability and repeatability of CPET variables were analysed using paired t-tests, the intraclass correlation coefficient (ICC), the coefficient of variation (CoV), and Bland and Altman limits of agreement. Changes in cardiopulmonary fitness during four weeks were analysed using paired t-tests. Seventeen sub-acute and chronic stroke patients (age 62.7 ± 10.4 years [mean ± SD]; 8 females) completed the test sessions. The median time post stroke was 350 days. There were 4 severely disabled, 1 moderately disabled and 12 mildly disabled patients. For test-retest, there were no statistically significant differences between TB1 and TB2 for most CPET variables. Peak oxygen uptake, peak heart rate, peak work rate and oxygen uptake at the ventilatory anaerobic threshold (VAT) and respiratory compensation point (RCP) showed good to excellent test-retest reliability (ICC 0.65-0.94). For all CPET variables, CoV was 4.1-14.5 %. The mean difference was close to zero in most of the CPET variables. There were no significant changes in most cardiopulmonary performance parameters during the 4-week period

  2. An economic analysis of robot-assisted therapy for long-term upper-limb impairment after stroke.

    Science.gov (United States)

    Wagner, Todd H; Lo, Albert C; Peduzzi, Peter; Bravata, Dawn M; Huang, Grant D; Krebs, Hermano I; Ringer, Robert J; Federman, Daniel G; Richards, Lorie G; Haselkorn, Jodie K; Wittenberg, George F; Volpe, Bruce T; Bever, Christopher T; Duncan, Pamela W; Siroka, Andrew; Guarino, Peter D

    2011-09-01

    Stroke is a leading cause of disability. Rehabilitation robotics have been developed to aid in recovery after a stroke. This study determined the additional cost of robot-assisted therapy and tested its cost-effectiveness. We estimated the intervention costs and tracked participants' healthcare costs. We collected quality of life using the Stroke Impact Scale and the Health Utilities Index. We analyzed the cost data at 36 weeks postrandomization using multivariate regression models controlling for site, presence of a prior stroke, and Veterans Affairs costs in the year before randomization. A total of 127 participants were randomized to usual care plus robot therapy (n=49), usual care plus intensive comparison therapy (n=50), or usual care alone (n=28). The average cost of delivering robot therapy and intensive comparison therapy was $5152 and $7382, respectively (Prehabilitation compared with traditional rehabilitation. Clinical Trial Registration- URL: http://clinicaltrials.gov. Unique identifier: NCT00372411.

  3. Clinical effectiveness of combined virtual reality and robot assisted fine hand motion rehabilitation in subacute stroke patients.

    Science.gov (United States)

    Huang, Xianwei; Naghdy, Fazel; Naghdy, Golshah; Du, Haiping

    2017-07-01

    Robot-assisted therapy is regarded as an effective and reliable method for the delivery of highly repetitive rehabilitation training in restoring motor skills after a stroke. This study focuses on the rehabilitation of fine hand motion skills due to their vital role in performing delicate activities of daily living (ADL) tasks. The proposed rehabilitation system combines an adaptive assist-as-needed (AAN) control algorithm and a Virtual Reality (VR) based rehabilitation gaming system (RGS). The developed system is described and its effectiveness is validated through clinical trials on a group of eight subacute stroke patients for a period of six weeks. The impact of the training is verified through standard clinical evaluation methods and measuring key kinematic parameters. A comparison of the pre- and post-training results indicates that the method proposed in this study can improve fine hand motion rehabilitation training effectiveness.

  4. The new era of minimally invasive interventions for prostate cancer: robot-assisted laparoscopic radical prostatectomy and focal therapy

    Directory of Open Access Journals (Sweden)

    Schatloff O

    2011-10-01

    Full Text Available Oscar Schatloff1, Alyssa S Louis2, Uri Lindner21Global Robotics Institute, Florida Hospital Celebration Health, Celebration, FL, USA; 2Division of Urology, Department of Surgical Oncology, University Health Network, Toronto, ON, CanadaAbstract: Prostate cancer remains a common but highly treatable disease. Innovations in prostate cancer treatment have allowed a transition toward minimally invasive approaches in an attempt to avoid treatment-related morbidities. In the middle of the treatment spectrum between radical open surgeries and active surveillance lies robot-assisted laparoscopic radical prostatectomy (RALP and focal therapy (FT. This review sets out the most current information on RALP and FT (including laser ablation, cryotherapy, high-intensity focused ultrasound, photodynamic therapy, and irreversible electroporation.Keywords: PCa, RALP, FT, laser ablation, cryotherapy, high-intensity focused ultrasound, photodynamic therapy, irreversible electroporation

  5. Hemorrhagic versus ischemic stroke: Who can best benefit from blended conventional physiotherapy with robotic-assisted gait therapy?

    Directory of Open Access Journals (Sweden)

    Frédéric Dierick

    Full Text Available Contrary to common belief of clinicians that hemorrhagic stroke survivors have better functional prognoses than ischemic, recent studies show that ischemic survivors could experience similar or even better functional improvements. However, the influence of stroke subtype on gait and posture outcomes following an intervention blending conventional physiotherapy with robotic-assisted gait therapy is missing.This study compared gait and posture outcome measures between ambulatory hemorrhagic patients and ischemic patients, who received a similar 4 weeks' intervention blending a conventional bottom-up physiotherapy approach and an exoskeleton top-down robotic-assisted gait training (RAGT approach with Lokomat.Forty adult hemiparetic stroke inpatient subjects were recruited: 20 hemorrhagic and 20 ischemic, matched by age, gender, side of hemisphere lesion, stroke severity, and locomotor impairments. Functional Ambulation Category, Postural Assessment Scale for Stroke, Tinetti Performance Oriented Mobility Assessment, 6 Minutes Walk Test, Timed Up and Go and 10-Meter Walk Test were performed before and after a 4-week long intervention. Functional gains were calculated for all tests.Hemorrhagic and ischemic subjects showed significant improvements in Functional Ambulation Category (P<0.001 and P = 0.008, respectively, Postural Assessment Scale for Stroke (P<0.001 and P = 0.003, 6 Minutes Walk Test (P = 0.003 and P = 0.015 and 10-Meter Walk Test (P = 0.001 and P = 0.024. Ischemic patients also showed significant improvements in Timed Up and Go. Significantly greater mean Functional Ambulation Category and Tinetti Performance Oriented Mobility Assessment gains were observed for hemorrhagic compared to ischemic, with large (dz = 0.81 and medium (dz = 0.66 effect sizes, respectively.Overall, both groups exhibited quasi similar functional improvements and benefits from the same type, length and frequency of blended conventional physiotherapy and RAGT

  6. Feasibility and safety of early lower limb robot-assisted training in sub-acute stroke patients: a pilot study.

    Science.gov (United States)

    Gandolfi, Marialuisa; Geroin, Christian; Tomelleri, Christopher; Maddalena, Isacco; Kirilova Dimitrova, Eleonora; Picelli, Alessandro; Smania, Nicola; Waldner, Andreas

    2017-12-01

    So far, the development of robotic devices for the early lower limb mobilization in the sub-acute phase after stroke has received limited attention. To explore the feasibility of a newly robotic-stationary gait training in sub-acute stroke patients. To report the training effects on lower limb function and muscle activation. A pilot study. Rehabilitation ward. Two sub-acute stroke inpatients and ten age-matched healthy controls were enrolled. Healthy controls served as normative data. Patients underwent 10 robot-assisted training sessions (20 minutes, 5 days/week) in alternating stepping movements (500 repetitions/session) on a hospital bed in addition to conventional rehabilitation. Feasibility outcome measures were compliance, physiotherapist time, and responses to self-report questionnaires. Efficacy outcomes were bilateral lower limb muscle activation pattern as measured by surface electromyography (sEMG), Motricity Index (MI), Medical Research Council (MRC) grade, and Ashworth Scale (AS) scores before and after training. No adverse events occurred. No significant differences in sEMG activity between patients and healthy controls were observed. Post-training improvement in MI and MRC scores, but no significant changes in AS scores, were recorded. Post-treatment sEMG analysis of muscle activation patterns showed a significant delay in rectus femoris offset (P=0.02) and prolonged duration of biceps femoris (P=0.04) compared to pretreatment. The robot-assisted training with our device was feasible and safe. It induced physiological muscle activations pattern in both stroke patients and healthy controls. Full-scale studies are needed to explore its potential role in post-stroke recovery. This robotic device may enrich early rehabilitation in subacute stroke patients by inducing physiological muscle activation patterns. Future studies are warranted to evaluate its effects on promoting restorative mechanisms involved in lower limb recovery after stroke.

  7. Development and validation of a composite scoring system for robot-assisted surgical training--the Robotic Skills Assessment Score.

    Science.gov (United States)

    Chowriappa, Ashirwad J; Shi, Yi; Raza, Syed Johar; Ahmed, Kamran; Stegemann, Andrew; Wilding, Gregory; Kaouk, Jihad; Peabody, James O; Menon, Mani; Hassett, James M; Kesavadas, Thenkurussi; Guru, Khurshid A

    2013-12-01

    A standardized scoring system does not exist in virtual reality-based assessment metrics to describe safe and crucial surgical skills in robot-assisted surgery. This study aims to develop an assessment score along with its construct validation. All subjects performed key tasks on previously validated Fundamental Skills of Robotic Surgery curriculum, which were recorded, and metrics were stored. After an expert consensus for the purpose of content validation (Delphi), critical safety determining procedural steps were identified from the Fundamental Skills of Robotic Surgery curriculum and a hierarchical task decomposition of multiple parameters using a variety of metrics was used to develop Robotic Skills Assessment Score (RSA-Score). Robotic Skills Assessment mainly focuses on safety in operative field, critical error, economy, bimanual dexterity, and time. Following, the RSA-Score was further evaluated for construct validation and feasibility. Spearman correlation tests performed between tasks using the RSA-Scores indicate no cross correlation. Wilcoxon rank sum tests were performed between the two groups. The proposed RSA-Score was evaluated on non-robotic surgeons (n = 15) and on expert-robotic surgeons (n = 12). The expert group demonstrated significantly better performance on all four tasks in comparison to the novice group. Validation of the RSA-Score in this study was carried out on the Robotic Surgical Simulator. The RSA-Score is a valid scoring system that could be incorporated in any virtual reality-based surgical simulator to achieve standardized assessment of fundamental surgical tents during robot-assisted surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Exercise

    Science.gov (United States)

    ... decreased bone density with an increased risk of fracture, and shallow, inefficient breathing. An exercise program needs ... and-Soul (Feb. 2013 issue) (.pdf) Download Document Rehabilitation: Recommendations for Persons with MS (.pdf) Download Brochure ...

  9. The New Jersey Institute of Technology Robot-Assisted Virtual Rehabilitation (NJIT-RAVR system for children with cerebral palsy: a feasibility study

    Directory of Open Access Journals (Sweden)

    Kelly Donna

    2009-11-01

    Full Text Available Abstract Background We hypothesize that the integration of virtual reality (VR with robot assisted rehabilitation could be successful if applied to children with hemiparetic CP. The combined benefits of increased attention provided by VR and the larger training stimulus afforded by adaptive robotics may increase the beneficial effects of these two approaches synergistically. This paper will describe the NJIT-RAVR system, which combines adaptive robotics with complex VR simulations for the rehabilitation of upper extremity impairments and function in children with CP and examine the feasibility of this system in the context of a two subject training study. Methods The NJIT-RAVR system consists of the Haptic Master, a 6 degrees of freedom, admittance controlled robot and a suite of rehabilitation simulations that provide adaptive algorithms for the Haptic Master, allowing the user to interact with rich virtual environments. Two children, a ten year old boy and a seven year old girl, both with spastic hemiplegia secondary to Cerebral Palsy were recruited from the outpatient center of a comprehensive pediatric rehabilitation facility. Subjects performed a battery of clinical testing and kinematic measurements of reaching collected by the NJIT-RAVR system. Subjects trained with the NJIT-RAVR System for one hour, 3 days a week for three weeks. The subjects played a combination of four or five simulations depending on their therapeutic goals, tolerances and preferences. Games were modified to increase difficulty in order to challenge the subjects as their performance improved. The testing battery was repeated following the training period. Results Both participants completed 9 hours of training in 3 weeks. No untoward events occurred and no adverse responses to treatment or complaints of cyber sickness were reported. One participant showed improvements in overall performance on the functional aspects of the testing battery. The second subject made

  10. [The use of a robot-assisted Gait Trainer GT1 in patients in the acute period of cerebral stroke: a pilot study].

    Science.gov (United States)

    Skvortsova, V I; Ivanova, G E; Kovrazhkina, E A; Rumiantseva, N A; Staritsyn, A N; Suvorov, A Iu; Sogomonian, E K

    2008-01-01

    An aim of the study was to evaluate efficacy of using Gait Trainer GT1, a robot-assisted gait trainer with a system of body-weight support, for the rehabilitation of gait in patients in the acute period of cerebral stroke. A main group included 30 patients in the acute period of ischemic and hemorrhage stroke and a control group--20 age- and sex matched patients. Patients of both groups had daily kinesitherapy sessions with a rehabilitator. Patients of the main group had additional sessions on the Gait Trainer GT1 from the moment of functional readiness to adequate orthostatic probe. Efficacy of rehabilitation was assessed in the four following phases: the first verticalization of patient in the standing position, adaptation of patient to the standing position, walking with assistance, independent walking. Muscular power (scores) in all muscles of low extremities, muscle tonus (the Ashfort scale), amplitude of tendinous reflexes on the reflexes scale, sensory disturbances and discoordination syndromes (specially elaborated scales), pathological positions in the axial muscular system and extremities, functional status (a steadiness scale, the Berg balance scale, the Barthel scale, 5 m test) were assessed in each phase. Stabilometry was conducted for objective evaluation of vertical balance function. The duration of sessions on GT1 and a number of exercises were depended on the patient's tolerability to physical activity. Percentage of relief was determined by the ability of a patient to balance in the standing position. Each patient had 8-10 sessions. A significant improvement of the functional status: ability to balance in standing position, walking, increase of self-care skills were observed in both groups. No significant differences in the level of functional improvements were found compared to the control group. However some peculiarities of the rehabilitation of primary neurologic deficit were observed during CT1-trainings: the normalization of muscle tonus

  11. Electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength after stroke.

    Science.gov (United States)

    Mehrholz, Jan; Pohl, Marcus; Platz, Thomas; Kugler, Joachim; Elsner, Bernhard

    2015-11-07

    Electromechanical and robot-assisted arm training devices are used in rehabilitation, and may help to improve arm function after stroke. To assess the effectiveness of electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength in people after stroke. We also assessed the acceptability and safety of the therapy. We searched the Cochrane Stroke Group's Trials Register (last searched February 2015), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library 2015, Issue 3), MEDLINE (1950 to March 2015), EMBASE (1980 to March 2015), CINAHL (1982 to March 2015), AMED (1985 to March 2015), SPORTDiscus (1949 to March 2015), PEDro (searched April 2015), Compendex (1972 to March 2015), and Inspec (1969 to March 2015). We also handsearched relevant conference proceedings, searched trials and research registers, checked reference lists, and contacted trialists, experts, and researchers in our field, as well as manufacturers of commercial devices. Randomised controlled trials comparing electromechanical and robot-assisted arm training for recovery of arm function with other rehabilitation or placebo interventions, or no treatment, for people after stroke. Two review authors independently selected trials for inclusion, assessed trial quality and risk of bias, and extracted data. We contacted trialists for additional information. We analysed the results as standardised mean differences (SMDs) for continuous variables and risk differences (RDs) for dichotomous variables. We included 34 trials (involving 1160 participants) in this update of our review. Electromechanical and robot-assisted arm training improved activities of daily living scores (SMD 0.37, 95% confidence interval (CI) 0.11 to 0.64, P = 0.005, I² = 62%), arm function (SMD 0.35, 95% CI 0.18 to 0.51, P arm muscle strength (SMD 0.36, 95% CI 0.01 to 0.70, P = 0.04, I² = 72%), but the quality of the evidence was low to very low

  12. Robot-assisted versus conventional laparoscopic operation in anus-preserving rectal cancer: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Cui Y

    2017-09-01

    Full Text Available Yongzhen Cui,1,2,* Cheng Li,3,* Zhongfa Xu,4 Yingming Wang,1,2 Yamei Sun,5 Huirong Xu,1 Zengjun Li,1 Yanlai Sun1 1Department of Gastrointestinal Cancer Surgery, Shandong Cancer Hospital Affiliated to Shandong University, Shandong Academy of Medical Sciences, 2School of Medicine and Life Sciences, University of Jinan-Shandong Academy of Medical Sciences, 3Department of President’s Office, Shandong Cancer Hospital Affiliated to Shandong University, Shandong Academy of Medical Sciences, 4Department of Gastrointestinal Surgery, The Affiliated Hospital of Shandong Academy of Medical Sciences, Jinan, 5Department of Clinical Laboratory, Zhucheng People’s Hospital of Shandong Province, Zhucheng, People’s Republic of China *These authors contributed equally to this work Objective: The aim of this meta-analysis is to provide recommendations for clinical practice and prevention of postoperative complications, such as circumferential resection margin (CRM involvement, and compare the amount of intraoperative bleeding, safety, operative time, recovery, outcomes, and clinical significance of robot-assisted and conventional laparoscopic procedures in anus-preserving rectal cancer. Methods: A literature search (PubMed was performed to identify biomedical research papers and abstracts of studies comparing robot-assisted and conventional laparoscopic procedures. We attempted to obtain the full-text link for papers published between 2000 and 2016, and hand-searched references for relevant literature. RevMan 5.3 software was used for the meta-analysis. Results: Nine papers (949 patients were eligible for inclusion; there were 473 patients (49.8% in the robotic group and 476 patients (50.2% in the laparoscopic group. According to the data provided in the literature, seven indicators were used to complete the evaluation. The results of the meta-analysis suggested that robot-assisted procedure was associated with lower intraoperative blood loss (mean difference

  13. Exercise

    DEFF Research Database (Denmark)

    Idorn, Manja; thor Straten, Eivind Per

    2016-01-01

    We recently demonstrated that voluntary exercise leads to an influx of immune cells in tumors and a greater than 60% reduction in tumor incidence and growth across several mouse models. Improved immunological control of tumor progression may have important clinical implications in the prevention...

  14. Robot-assisted pancreatoduodenectomy with preservation of the vascular supply for autologous islet cell isolation and transplantation: a case report

    Directory of Open Access Journals (Sweden)

    Giulianotti Piero

    2012-03-01

    Full Text Available Abstract Introduction For patients with chronic pancreatitis presenting with medically intractable abdominal pain, surgical intervention may be the only treatment option. However, extensive pancreatic resections are typically performed open and are associated with a substantial amount of postoperative pain, wound complications and long recovery time. Minimally invasive surgery offers an avenue to improve results; however, current limitations of laparoscopic surgery render its application in the setting of chronic pancreatitis technically demanding. Additionally, pancreatic resections are associated with a high incidence of diabetes. Transplantation of islets isolated from the resected pancreas portion offers a way to prevent post-surgical diabetes; however, preservation of the vascular supply during pancreatic resection, which determines islet cell viability, is technically difficult using current laparoscopic approaches. With recent advances in the surgical field, robotic surgery now provides a means to overcome these obstacles to achieve the end goals of pain relief and preserved endocrine function. We present the first report of a novel, minimally invasive robotic approach for resection of the pancreatic head that preserves vascular supply and enables the isolation of a high yield of viable islets for transplantation. Case presentation A 35-year old Caucasian woman presented with intractable chronic abdominal pain secondary to chronic pancreatitis, with a stricture of her main pancreatic duct at the level of the ampulla of Vater and distal dilatation. She was offered a robotic-assisted pylorus-preserving pancreatoduodenectomy and subsequent islet transplantation, to both provide pain relief and preserve insulin-secretory reserves. Conclusion We present a novel, minimally invasive robotic approach for resection of the pancreatic head with complete preservation of the vascular supply, minimal warm ischemia time (less than three minutes and

  15. Cost-analysis of robotic-assisted laparoscopic hysterectomy versus total abdominal hysterectomy for women with endometrial cancer and atypical complex hyperplasia

    DEFF Research Database (Denmark)

    Herling, Suzanne Forsyth; Palle, Connie; Møller, Ann M.

    2016-01-01

    INTRODUCTION: The aim of this study was to analyse the hospital cost of treatment with robotic-assisted laparoscopic hysterectomy and total abdominal hysterectomy for women with endometrial cancer or atypical complex hyperplasia and to identify differences in resource use and cost. MATERIAL...... AND METHODS: This cost analysis was based on two cohorts: women treated with robotic-assisted laparoscopic hysterectomy (n = 202) or with total abdominal hysterectomy (n = 158) at Copenhagen University Hospital, Herlev, Denmark. We conducted an activity-based cost analysis including consumables and healthcare...... professionals' salaries. As cost-drivers we included severe complications, duration of surgery, anesthesia and stay at the post-anesthetic care unit, as well as number of hospital bed-days. Ordinary least-squares regression was used to explore the cost variation. The primary outcome was cost difference...

  16. Quality-of-life change associated with robotic-assisted therapy to improve hand motor function in patients with subacute stroke: a randomized clinical trial.

    Science.gov (United States)

    Kutner, Nancy G; Zhang, Rebecca; Butler, Andrew J; Wolf, Steven L; Alberts, Jay L

    2010-04-01

    At 6 months poststroke, most patients cannot incorporate their affected hand into daily activities, which in turn is likely to reduce their perceived quality of life. This preliminary study explored change in patient-reported, health-related quality of life associated with robotic-assisted therapy combined with reduced therapist-supervised training. A single-blind, multi-site, randomized clinical trial was conducted. Seventeen individuals who were 3 to 9 months poststroke participated. Sixty hours of therapist-supervised repetitive task practice (RTP) was compared with 30 hours of RTP combined with 30 hours of robotic-assisted therapy. Participants completed the Stroke Impact Scale (SIS) at baseline, immediately postintervention, and 2 months postintervention. Change in SIS score domains was assessed in a mixed model analysis. The combined therapy group had a greater increase in rating of mood from preintervention to postintervention, and the RTP-only group had a greater increase in rating of social participation from preintervention to follow-up. Both groups had statistically significant improvement in activities of daily living and instrumental activities of daily living scores from preintervention to postintervention. Both groups reported significant improvement in hand function postintervention and at follow-up, and the magnitude of these changes suggested clinical significance. The combined therapy group had significant improvements in stroke recovery rating postintervention and at follow-up, which appeared clinically significant; this also was true for stroke recovery rating from preintervention to follow-up in the RTP-only group. LIMITATIONS OUTCOMES: of 30 hours of RTP in the absence of robotic-assisted therapy remain unknown. Robotic-assisted therapy may be an effective alternative or adjunct to the delivery of intensive task practice interventions to enhance hand function recovery in patients with stroke.

  17. An unexpected resident in the ileum detected during robot-assisted laparoscopic radical cystoprostatectomy and intracorporeal Studer pouch formation: Taenia saginata parasite.

    Science.gov (United States)

    Canda, Abdullah Erdem; Asil, Erem; Balbay, Mevlana Derya

    2011-02-01

    A case of moving ileal Taenia saginata parasites is presented with demonstrative images. We came across the parasites surprisingly while performing robot-assisted laparoscopic radical cystoprostatectomy with intracorporeal Studer pouch urinary diversion. We recommend stool sample evaluation in the preoperative period for possible presence of intestinal parasitic diseases, particularly in patients with bladder cancer who are admitted from areas with an increased incidence of intestinal parasitic diseases, before opening the bowel segments during surgery to perform radical cystectomy and urinary diversion.

  18. Robot-Assisted Laparoscopic Radical Prostatectomy for Patients with Prostatic Cancer and Factors Promoting Installation of the Robotic Surgical Equipment-Questionnaire Survey

    OpenAIRE

    塚本, 泰司; 田中, 滋

    2015-01-01

    We conducted a questionnaire survey of hospitals with robot-assisted surgical equipment to study changes of the surgical case loads after its installation and the managerial strategies for its purchase. The study included 154 hospitals (as of April 2014) that were queried about their radical prostatectomy case loads from January 2009 to December 2013, strategies for installation of the equipment in their hospitals, and other topics related to the study purpose. The overall response rate of ho...

  19. Robot-assisted "Santosh-Post Graduate Institute tubularized flap pyelovesicostomy" in a solitary functioning kidney with giant hydronephrosis: A minimally invasive salvage procedure.

    Science.gov (United States)

    Kumar, Santosh; Singh, Shivanshu; Kumar, Navneet

    2016-03-01

    We describe a case of a solitary functioning kidney with giant hydronephrosis secondary to ureteropelvic junction obstruction in a young girl who underwent successful robot-assisted tubularized flap pyelovesicostomy. The aim of this report was to highlight the feasibility and efficacy of this technique in salvaging such renal moieties and to present a brief review of the surgical options available for the management of giant hydronephrosis.

  20. Randomized, sham-controlled trial based on transcranial direct current stimulation and wrist robot-assisted integrated treatment on subacute stroke patients: Intermediate results.

    Science.gov (United States)

    Mazzoleni, Stefano; Tran, Vi Do; Iardella, Laura; Dario, Paolo; Posteraro, Federico

    2017-07-01

    The main goal of this study is to analyse the effects of combined transcranial direct current stimulation (tDCS) and wrist robot-assisted therapy in subacute stroke patients. Twenty-four patients were included in this study and randomly assigned to the experimental (EG) or control group (CG). All participants performed wrist robot-assisted training a) in conjunction with tDCS (real stimulation for patients in EG) or b) without tDCS (sham stimulation for patients in CG). Clinical scales and kinematic parameters recorded by the robot were used for the assessment. Clinical outcome measures show a significant decrease in motor impairment after the treatment in both groups. Kinematic data show several significant improvements after the integrated therapy in both groups. However, no significant differences in both clinical outcome measures and kinematic parameters was found between two groups. The potential advantages of combined tDCS and wrist robot-assisted therapy in subacute stroke patients are still unclear.

  1. Comparative health technology assessment of robotic-assisted, direct manual laparoscopic and open surgery: a prospective study.

    Science.gov (United States)

    Turchetti, Giuseppe; Pierotti, Francesca; Palla, Ilaria; Manetti, Stefania; Freschi, Cinzia; Ferrari, Vincenzo; Cuschieri, Alfred

    2017-02-01

    Despite many publications reporting on the increased hospital cost of robotic-assisted surgery (RAS) compared to direct manual laparoscopic surgery (DMLS) and open surgery (OS), the reported health economic studies lack details on clinical outcome, precluding valid health technology assessment (HTA). The present prospective study reports total cost analysis on 699 patients undergoing general surgical, gynecological and thoracic operations between 2011 and 2014 in the Italian Public Health Service, during which period eight major teaching hospitals treated the patients. The study compared total healthcare costs of RAS, DMLS and OS based on prospectively collected data on patient outcome in addition to healthcare costs incurred by the three approaches. The cost of RAS operations was significantly higher than that of OS and DMLS for both gynecological and thoracic operations (p DMLS. Total costs of general surgery RAS were significantly higher than those of OS (p DMLS general surgery. Indirect costs were significantly lower in RAS compared to both DMLS general surgery and OS gynecological surgery due to the shorter length of hospital stay of RAS approach (p < 0.001). Additionally, in all specialties compared to OS, patients treated by RAS experienced a quicker recovery and significantly less pain during the hospitalization and after discharge. The present HTA while confirming higher total healthcare costs for RAS operations identified significant clinical benefits which may justify the increased expenditure incurred by this approach.

  2. Robot-assisted gait training versus treadmill training in patients with Parkinson's disease: a kinematic evaluation with gait profile score.

    Science.gov (United States)

    Galli, M; Cimolin, V; De Pandis, M F; Le Pera, D; Sova, I; Albertini, G; Stocchi, F; Franceschini, M

    2016-01-01

    The purpose of this study was to quantitatively compare the effects, on walking performance, of end-effector robotic rehabilitation locomotor training versus intensive training with a treadmill in Parkinson's disease (PD). Fifty patients with PD were randomly divided into two groups: 25 were assigned to the robot-assisted therapy group (RG) and 25 to the intensive treadmill therapy group (IG). They were evaluated with clinical examination and 3D quantitative gait analysis [gait profile score (GPS) and its constituent gait variable scores (GVSs) were calculated from gait analysis data] at the beginning (T0) and at the end (T1) of the treatment. In the RG no differences were found in the GPS, but there were significant improvements in some GVSs (Pelvic Obl and Hip Ab-Add). The IG showed no statistically significant changes in either GPS or GVSs. The end-effector robotic rehabilitation locomotor training improved gait kinematics and seems to be effective for rehabilitation in patients with mild PD.

  3. Impact of posterior rhabdosphincter reconstruction during robot-assisted radical prostatectomy: retrospective analysis of time to continence.

    Science.gov (United States)

    Woo, Jason R; Shikanov, Sergey; Zorn, Kevin C; Shalhav, Arieh L; Zagaja, Gregory P

    2009-12-01

    Posterior rhabdosphincter (PR) reconstruction during robot-assisted radical prostatectomy (RARP) was introduced in an attempt to improve postoperative continence. In the present study, we evaluate time to achieve continence in patients who are undergoing RARP with and without PR reconstruction. A prospective RARP database was searched for most recent cases that were accomplished with PR reconstruction (group 1, n = 69) or with standard technique (group 2, n = 63). We performed the analysis applying two definitions of continence: 0 pads per day or 0-1 security pad per day. Patients were evaluated by telephone interview. Statistical analysis was carried out using the Kaplan-Meier method and log-rank test. With PR reconstruction, continence was improved when defined as 0-1 security pad per day (median time of 90 vs 150 days; P = 0.01). This difference did not achieve statistical significance when continence was defined as 0 pads per day (P = 0.12). A statistically significant improvement in continence rate and time to achieve continence is seen in patients who are undergoing PR reconstruction during RARP, with continence defined as 0-1 security/safety pad per day. A larger, prospective and randomized study is needed to better understand the impact of this technique on postoperative continence.

  4. Implementing assessments of robot-assisted technical skill in urological education: a systematic review and synthesis of the validity evidence.

    Science.gov (United States)

    Goldenberg, Mitchell G; Lee, Jason Y; Kwong, Jethro C C; Grantcharov, Teodor P; Costello, Anthony

    2018-03-31

    To systematically review and synthesise the validity evidence supporting intraoperative and simulation-based assessments of technical skill in urological robot-assisted surgery (RAS), and make evidence-based recommendations for the implementation of these assessments in urological training. A literature search of the Medline, PsycINFO and Embase databases was performed. Articles using technical skill and simulation-based assessments in RAS were abstracted. Only studies involving urology trainees or faculty were included in the final analysis. Multiple tools for the assessment of technical robotic skill have been published, with mixed sources of validity evidence to support their use. These evaluations have been used in both the ex vivo and in vivo settings. Performance evaluations range from global rating scales to psychometrics, and assessments are carried out through automation, expert analysts, and crowdsourcing. There have been rapid expansions in approaches to RAS technical skills assessment, both in simulated and clinical settings. Alternative approaches to assessment in RAS, such as crowdsourcing and psychometrics, remain under investigation. Evidence to support the use of these metrics in high-stakes decisions is likely insufficient at present. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  5. Feasibility and early outcomes of robotic-assisted laparoscopic Mitrofanoff appendicovesicostomy in patients with prune belly syndrome.

    Science.gov (United States)

    Wille, Mark A; Jayram, Gautam; Gundeti, Mohan S

    2012-01-01

    To evaluate the feasibility and report our initial experience with Robotic-Assisted Laparoscopic Mitrofanoff Appendicovesicostomy (RALMA) in patients with prune belly syndrome. The Mitrofanoff appendicovesicostomy procedure uses the appendix to create an easily accessible continent, catheterizable channel into the urinary bladder. Historically, the procedure is performed by an open surgical approach in prune belly patients. We describe our initial experience herein. Between October 2008 and February 2010 three patients with prune belly syndrome underwent RALMA. The appendicovesicostomy anastomosis was performed on the anterior bladder wall and the stoma was brought to the umbilical site or right lower quadrant. At least 4 cm of detrusor backing was ensured. The appendicovesicostomy stent was left in place for 4 weeks postoperatively before initiation of catheterization. Mean age at surgery was 9.7 years (range 5-14 years). Blood loss volume was 20 mL in each case. Overall mean operative time was 352 min (range 319-402 min). There were no intraoperative complications and no open conversions. There was one postoperative complication in the form of wound infection. All patients are catheterizing their stomas and are continent at an average follow-up of 14.7 months (range 5-21 months). In our initial experience, RALMA is a feasible option with encouraging early experience for creating a continent catheterizable channel into the urinary bladder in patients with prune belly syndrome. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  6. Virtual Reality to control active participation in a subacute stroke patient during robot-assisted gait training.

    Science.gov (United States)

    Bergmann, J; Krewer, C; Müller, F; Koenig, A; Riener, R

    2011-01-01

    Virtual Reality (VR) provides a promising medium to enrich robot assisted rehabilitation. VR applications present the opportunity to engage patients in therapy and control participation. The aim of this study was to investigate two strategies to control active participation of a stroke patient focusing on the involvement of the paretic leg in task solution. A subacute stroke patient with a severe hemiparesis performed two experiments on the driven gait orthosis Lokomat. Patient activity was quantified by weighted interaction torques measured in both legs (experiment A) and the paretic leg only (experiment B). The patient was able to successfully implement both the bilateral and unilateral control modality. Both control modes increased the motor output of the paretic leg, however the paretic leg control mode resulted in a much more differentiated regulation of the activity in the leg. Both control modes are appropriate approaches to enhance active participation and increase motor output in the paretic leg. Further research should evaluate the therapeutic benefit of patients with hemiparesis using the unilateral control mode depending on the severity of their impairment. © 2011 IEEE

  7. Noninvasive continuous blood pressure monitoring by the ClearSight system during robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Sakai, Yoko; Yasuo M, Tsutsumi; Oyama, Takuro; Murakami, Chiaki; Kakuta, Nami; Tanaka, Katsuya

    2018-01-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) is commonly performed in the surgical treatment of prostate cancer. However, the steep Trendelenburg position (25) and pneumoperitoneum required for this procedure can sometimes cause hemodynamic changes. Although blood pressure is traditionally monitored invasively during RALRP, the ClearSight system (BMEYE, Amsterdam, The Netherlands) enables a totally noninvasive and simple continuous blood pressure and cardiac output monitoring based on finger arterial pressure pulse contour analysis. We therefore investigated whether noninvasive continuous arterial blood pressure measurements using the ClearSight system were comparable to those obtained invasively in patients undergoing RALRP. Ten patients scheduled for RALRP with American Society of Anesthesiologists physical status I-II were included in this study. At each of the seven defined time points, noninvasive and invasive blood pressure measurements were documented and compared in each patient using Bland-Altman analysis. Although the blood pressure measured with the ClearSight system correlated with that measured invasively, a large difference between the values obtained by the two devices was noted. The ClearSight system was unable to detect blood pressure accurately during RALRP, suggesting that blood pressure monitoring using this device alone is not feasible in this small patient population. J. Med. Invest. 65:69-73, February, 2018.

  8. Intraoperative frozen pathology during robot-assisted laparoscopic radical prostatectomy: can ALEXIS™ trocar make it easy and fast?

    Science.gov (United States)

    Almeida, Gilberto Laurino; Musi, Gennaro; Mazzoleni, Federica; Matei, Deliu Victor; Brescia, Antonio; Detti, Serena; de Cobelli, Ottavio

    2013-10-01

    To describe the first series of robot-assisted laparoscopic radical prostatectomy (RALP) using the ALEXIS™ trocar device when removal of the specimen is necessary for intraoperative frozen-section pathology. Consecutive RALP using the ALEXIS were prospectively catalogue. Perioperative data, including preoperative oncologic diagnosis, operative time, estimated blood loss (EBL), size of incision for umbilical trocar, complications related to trocar, and length of hospital stay, were analyzed. One hundred twenty-eight patients were analyzed. The mean operative time was 216 minutes, mean time to trocar placement was 4 minutes, and mean EBL was 172 mL. The incision size for a trocar was 2-3 cm in 117 patients and 1 incisional hernia was observed. The mean hospital stay was 3 days and mean follow-up was 4 months. The ALEXIS trocar provides an easy and fast intraoperative removal of the specimen for frozen pathology during RALP, even for large prostates. Safe and cosmetic results with a low intraoperative complication rate are acquired with the wound retractor.

  9. Robot-assisted gait training for stroke patients: current state of the art and perspectives of robotics

    Directory of Open Access Journals (Sweden)

    Morone G

    2017-05-01

    Full Text Available Giovanni Morone,1,2 Stefano Paolucci,1,2 Andrea Cherubini,3 Domenico De Angelis,1 Vincenzo Venturiero,1 Paola Coiro,1 Marco Iosa1,2 1Private Inpatient Unit, 2Clinical Laboratory of Experimental Neurorehabilitation, IRCCS Santa Lucia Foundation, Rome, Italy; 3Department of Robotics, LIRMM UM-CNRS, Montpellier, France Abstract: In this review, we give a brief outline of robot-mediated gait training for stroke patients, as an important emerging field in rehabilitation. Technological innovations are allowing rehabilitation to move toward more integrated processes, with improved efficiency and less long-term impairments. In particular, robot-mediated neurorehabilitation is a rapidly advancing field, which uses robotic systems to define new methods for treating neurological injuries, especially stroke. The use of robots in gait training can enhance rehabilitation, but it needs to be used according to well-defined neuroscientific principles. The field of robot-mediated neurorehabilitation brings challenges to both bioengineering and clinical practice. This article reviews the state of the art (including commercially available systems and perspectives of robotics in poststroke rehabilitation for walking recovery. A critical revision, including the problems at stake regarding robotic clinical use, is also presented. Keywords: exoskeleton, neurorehabilitation, robot-assisted walking training, wearable robot, activities of daily living, motor learning, plasticity

  10. Health-related quality of life after robotic-assisted laparoscopic hysterectomy for women with endometrial cancer

    DEFF Research Database (Denmark)

    Herling, Suzanne Forsyth; Møller, Ann M; Palle, Connie

    2016-01-01

    OBJECTIVE: The aim of this prospective cohort study using patient-reported outcome measures (PROMs) was to detect short term changes in functioning, symptoms and health-related quality of life (HRQoL) after robotic-assisted laparoscopic hysterectomy (RALH) for endometrial cancer or atypical compl......, gastrointestinal symptoms, appetite, ability to perform work and hobbies, change of taste and sexually related problems should be addressed in future research and in the pre- and postoperative care for women undergoing RALH....... postoperatively, but back to baseline level at 5 weeks. Ability to perform work or hobbies and change of taste were still affected at 5 weeks. CONCLUSIONS: HRQoL and postoperative symptoms were overall back to the preoperative level 5 weeks after RALH. These findings indicate fatigue, pain, constipation...... hyperplasia. METHODS/MATERIALS: A total of 139 women answered the EORTC C-30, EN-24 and EQ-5D-3L preoperatively (baseline) by face to face interview and again 1 week, 5 weeks and 4 months postoperatively by telephone interview. The women furthermore reported their level of activity compared to their habitual...

  11. Combined Oocyte Retrieval and Robot-assisted Hysterectomy in a Super Morbidly Obese Patient with Endometrial Carcinoma.

    Science.gov (United States)

    Chung, Esther H; Brady, Paula C; Smith, Kimberly Keefe; Davis, Michelle R; Muto, Michael G; Ashby, Rachel K; Ginsburg, Elizabeth S

    2018-03-01

    To report on the unique, innovative management of a super morbidly obese patient presenting for fertility preservation in the setting of Grade 2 endometrioid endometrial adenocarcinoma. A back-to-back oocyte retrieval and robot-assisted total laparoscopic hysterectomy (RA-TLH) with bilateral salpingo-oophorectomy (BSO) was performed in a 37-year-old nulligravid woman with super morbid obesity (BMI 63 kg/m 2 ) with endometrial cancer. the successful retrieval of oocytes for fertility preservation and oncologic intervention via RA-TLH with BSO in the same operative and anesthetic episode. This combined procedure strategy was successful in our case and is a feasible option for similar high-risk patients in the future. Identifying safe and effective approaches for oocyte retrieval in morbidly obese patients represents a pressing need as obesity rates rise among reproductive-aged women. Back-to-back oocyte retrieval and RA-TLH with BSO are not only feasible, but could also decrease significant anesthetic risks for morbidly obese patients. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  12. Robotic-assisted partial nephrectomy: surgical technique using a 3-arm approach and sliding-clip renorrhaphy

    Directory of Open Access Journals (Sweden)

    Jose M. Cabello

    2009-04-01

    Full Text Available INTRODUCTION: For the treatment of renal tumors, minimally invasive nephron-sparing surgery has become increasingly performed due to proven efficiency and excellent functional and oncological outcomes. The introduction of robotics into urologic laparoscopic surgery has allowed surgeons to perform challenging procedures in a reliable and reproducible manner. We present our surgical technique for robotic assisted partial nephrectomy (RPN using a 3-arm approach, including a sliding-clip renorrhaphy. MATERIAL AND METHODS: Our RPN technique is presented which describes the trocar positioning, hilar dissection, tumor identification using intraoperative ultrasound for margin determination, selective vascular clamping, tumor resection, and reconstruction using a sliding-clip technique. CONCLUSION: RPN using a sliding-clip renorrhaphy is a valid and reproducible surgical technique that reduces the challenge of the procedure by taking advantage of the enhanced visualization and control afforded by the robot. The renorrhaphy described is performed under complete control of the console surgeon, and has demonstrated a reduction in the warm ischemia times in our series.

  13. Late Onset of CSF Rhinorrhea in a Postoperative Transsphenoidal Surgery Patient Following Robotic-Assisted Abdominal Hysterectomy

    Directory of Open Access Journals (Sweden)

    Justin T. Dowdy MD

    2014-01-01

    Full Text Available Cerebrospinal fluid (CSF leak is the most commonly encountered perioperative complication in transsphenoidal surgery for pituitary lesions. Direct closure with a combination of autologous fat, local bone, and/or synthetic grafts remains the standard of care for leaks encountered at the time of surgery as well as postoperatively. The development of the vascularized nasoseptal flap as a closure technique has increased the surgeon’s capacity to correct even larger openings in the dura of the sella as well as widely exposed anterior skull base defects. Yet these advances in the technical nuances for management of post-transsphenoidal CSF leak are useless without the ability to recognize a CSF leak by physical examination, clinical history, biochemical testing, or radiographic assessment. Here, we report a case of a patient who developed a CSF leak 28 years after transsphenoidal surgery, precipitated by a robotic-assisted hysterectomy during which increased intra-abdominal pressure and steep Trendelenberg positioning were both factors. Given the remote nature of the patient’s transsphenoidal surgery and relative paucity of data regarding such a complication, the condition went unrecognized for several months. We review the available literature regarding risk and pathophysiology of CSF leak following abdominal surgery and propose the need for increased vigilance in identification of such occurrences with the increasing acceptance and popularity of minimally invasive abdominal and pelvic surgeries as standards in the field.

  14. Robotic-assisted versus open radical cystectomy in bladder cancer: A meta-analysis of four randomized controlled trails.

    Science.gov (United States)

    Tang, Jin-Qiu; Zhao, Zhihong; Liang, Yiwen; Liao, Guixiang

    2018-02-01

    Robot-assisted radical cystectomy (RARC) is increasing annually for treatment of bladder cancer. The objective of this meta-analysis was to compare the safety and efficacy of RARC and open radical cystectomy (ORC) for bladder cancer. Our meta-analysis searches were conducted using PubMed, Web of Science, and Cochrane Library databases to identify randomized controlled trials (RCT) assessing the two techniques. Four RCT studies were identified, including 239 cases. Our studies indicated that RARC was associated with longer operative time (WMD: 69.69, 95% CI:17.25 to122.12; P= 0.009), lower estimated blood loss (WMD: -299.83, 95% CI:-414.66to -184.99; P<0.00001). The two groups had no significant difference in overall perioperative complications, length of hospital stay, lymph node yield and positive surgical margins. RARC is mini-invasive alternative to ORC for bladder cancer. The advantage of RARC was reduced estimated blood loss. More studies are needed to compare the two techniques. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Robot-assisted adaptive training: custom force fields for teaching movement patterns.

    Science.gov (United States)

    Patton, James L; Mussa-Ivaldi, Ferdinando A

    2004-04-01

    Based on recent studies of neuro-adaptive control, we tested a new iterative algorithm to generate custom training forces to "trick" subjects into altering their target-directed reaching movements to a prechosen movement as an after-effect of adaptation. The prechosen movement goal, a sinusoidal-shaped path from start to end point, was never explicitly conveyed to the subject. We hypothesized that the adaptation would cause an alteration in the feedforward command that would result in the prechosen movement. Our results showed that when forces were suddenly removed after a training period of 330 movements, trajectories were significantly shifted toward the prechosen movement. However, de-adaptation occurred (i.e., the after-effect "washed out") in the 50-75 movements that followed the removal of the training forces. A second experiment suppressed vision of hand location and found a detectable reduction in the washout of after-effects, suggesting that visual feedback of error critically influences learning. A final experiment demonstrated that after-effects were also present in the neighborhood of training--44% of original directional shift was seen in adjacent, unpracticed movement directions to targets that were 60 degrees different from the targets used for training. These results demonstrate the potential for these methods for teaching motor skills and for neuro-rehabilitation of brain-injured patients. This is a form of "implicit learning," because unlike explicit training methods, subjects learn movements with minimal instructions, no knowledge of, and little attention to the trajectory.

  16. Robot-assisted practice of gait and stair climbing in nonambulatory stroke patients.

    Science.gov (United States)

    Hesse, Stefan; Tomelleri, Christopher; Bardeleben, Anita; Werner, Cordula; Waldner, Andreas

    2012-01-01

    A novel gait robot enabled nonambulatory patients the repetitive practice of gait and stair climbing. Thirty nonambulatory patients with subacute stroke were allocated to two groups. During 60 min sessions every workday for 4 weeks, the experimental group received 30 min of robot training and 30 min of physiotherapy and the control group received 60 min of physiotherapy. The primary variable was gait and stair climbing ability (Functional Ambulation Categories [FAC] score 0-5); secondary variables were gait velocity, Rivermead Mobility Index (RMI), and leg strength and tone blindly assessed at onset, intervention end, and follow-up. Both groups were comparable at onset and functionally improved over time. The improvements were significantly larger in the experimental group with respect to the FAC, RMI, velocity, and leg strength during the intervention. The FAC gains (mean +/- standard deviation) were 2.4 +/- 1.2 (experimental group) and 1.2 +/- 1.5 (control group), p = 0.01. At the end of the intervention, seven experimental group patients and one control group patient had reached an FAC score of 5, indicating an ability to climb up and down one flight of stairs. At follow-up, this superior gait ability persisted. In conclusion, the therapy on the novel gait robot resulted in a superior gait and stair climbing ability in nonambulatory patients with subacute stroke; a higher training intensity was the most likely explanation. A large randomized controlled trial should follow.

  17. Robot-assisted training of the kinesthetic sense: enhancing proprioception after stroke

    Directory of Open Access Journals (Sweden)

    Dalia eDe Santis

    2015-01-01

    Full Text Available Proprioception has a crucial role in promoting or hindering motor learning. In particular, an intact position sense strongly correlates with the chances of recovery after stroke. A great majority of neurological patients present both motor dysfunctions and impairments in kinesthesia, but traditional robot and virtual reality training techniques focus either in recovering motor functions or in assessing proprioceptive deficits. An open challenge is to implement effective and reliable tests and training protocols for proprioception that go beyond the mere position sense evaluation and exploit the intrinsic bidirectionality of the kinesthetic sense, which refers to both sense of position and sense of movement. Modulated haptic interaction has a leading role in promoting sensorimotor integration and it is a natural way to enhance volitional effort. Therefore, we designed a preliminary clinical study to test a new proprioception-based motor training technique for augmenting kinesthetic awareness via haptic feedback. The feedback was provided by a robotic manipulandum and the test involved 7 chronic hemiparetic subjects over three weeks. The protocol included evaluation sessions, that consisted of a psychometric estimate of the subject’s kinesthetic sensation, and training sessions, in which the subject executed planar reaching movements in the absence of vision and under a minimally assistive haptic guidance made by sequences of graded force pulses. The bidirectional haptic interaction between the subject and the robot was optimally adapted to each participant in order to achieve a uniform task difficulty over the workspace. All the subjects consistently improved in the perceptual scores as a consequence of training. Moreover, they could minimize the level of haptic guidance in time. Results suggest that the proposed method is effective in enhancing kinesthetic acuity, but the level of impairment may affect the ability of subjects to retain their

  18. Robot-assisted training of the kinesthetic sense: enhancing proprioception after stroke.

    Science.gov (United States)

    De Santis, Dalia; Zenzeri, Jacopo; Casadio, Maura; Masia, Lorenzo; Riva, Assunta; Morasso, Pietro; Squeri, Valentina

    2014-01-01

    Proprioception has a crucial role in promoting or hindering motor learning. In particular, an intact position sense strongly correlates with the chances of recovery after stroke. A great majority of neurological patients present both motor dysfunctions and impairments in kinesthesia, but traditional robot and virtual reality training techniques focus either in recovering motor functions or in assessing proprioceptive deficits. An open challenge is to implement effective and reliable tests and training protocols for proprioception that go beyond the mere position sense evaluation and exploit the intrinsic bidirectionality of the kinesthetic sense, which refers to both sense of position and sense of movement. Modulated haptic interaction has a leading role in promoting sensorimotor integration, and it is a natural way to enhance volitional effort. Therefore, we designed a preliminary clinical study to test a new proprioception-based motor training technique for augmenting kinesthetic awareness via haptic feedback. The feedback was provided by a robotic manipulandum and the test involved seven chronic hemiparetic subjects over 3 weeks. The protocol included evaluation sessions that consisted of a psychometric estimate of the subject's kinesthetic sensation, and training sessions, in which the subject executed planar reaching movements in the absence of vision and under a minimally assistive haptic guidance made by sequences of graded force pulses. The bidirectional haptic interaction between the subject and the robot was optimally adapted to each participant in order to achieve a uniform task difficulty over the workspace. All the subjects consistently improved in the perceptual scores as a consequence of training. Moreover, they could minimize the level of haptic guidance in time. Results suggest that the proposed method is effective in enhancing kinesthetic acuity, but the level of impairment may affect the ability of subjects to retain their improvement in time.

  19. Patterns-of-care and health economic analysis of robot-assisted radical prostatectomy in the Australian public health system.

    Science.gov (United States)

    Basto, Marnique; Sathianathen, Niranjan; Te Marvelde, Luc; Ryan, Shane; Goad, Jeremy; Lawrentschuk, Nathan; Costello, Anthony J; Moon, Daniel A; Heriot, Alexander G; Butler, Jim; Murphy, Declan G

    2016-06-01

    To compare patterns of care and peri-operative outcomes of robot-assisted radical prostatectomy (RARP) with other surgical approaches, and to create an economic model to assess the viability of RARP in the public case-mix funding system. We retrospectively reviewed all radical prostatectomies (RPs) performed for localized prostate cancer in Victoria, Australia, from the Victorian Admitted Episode Dataset, a large administrative database that records all hospital inpatient episodes in Victoria. The first database, covering the period from July 2010 to April 2013 (n = 5 130), was used to compare length of hospital stay (LOS) and blood transfusion rates between surgical approaches. This was subsequently integrated into an economic model. A second database (n = 5 581) was extracted to cover the period between July 2010 and June 2013, three full financial years, to depict patterns of care and make future predictions for the 2014-2015 financial year, and to perform a hospital volume analysis. We then created an economic model to evaluate the incremental cost of RARP vs open RP (ORP) and laparoscopic RP (LRP), incorporating the cost-offset from differences in LOS and blood transfusion rate. The economic model constructs estimates of the diagnosis-related group (DRG) costs of ORP and LRP, adds the gross cost of the surgical robot (capital, consumables, maintenance and repairs), and manipulates these DRG costs to obtain a DRG cost per day, which can be used to estimate the cost-offset associated with RARP in comparison with ORP and LRP. Economic modelling was performed around a base-case scenario, assuming a 7-year robot lifespan and 124 RARPs performed per financial year. One- and two-way sensitivity analyses were performed for the four-arm da Vinci SHD, Si and Si dual surgical systems (Intuitive Surgical Ltd, Sunnyvale, CA, USA). We identified 5 581 patients who underwent RP in 20 hospitals in Victoria with an open, laparoscopic or robot-assisted surgical approach in the

  20. Anesthesiologic Effects of Transperitoneal Versus Extraperitoneal Approach During Robot-Assisted Radical Prostatectomy: Results of a Prospective Randomized Study

    Directory of Open Access Journals (Sweden)

    Fabrizio Dal Moro

    2015-06-01

    Full Text Available ABSTRACTObjectives:To compare the effects of CO2 insufflation on hemodynamics and oxygen levels and on acid-base level during Robot-Assisted Radical Prostatectomy (RARP with transperitoneal (TP versus extra-peritoneal (EP accesses.Materials and Methods:Sixty-two patients were randomly assigned to TP (32 and EP (30 to RARP. Pre-operation data were collected for all patients. Hemodynamic, respiratory and blood acid-base parameters were measured at the moment of induction of anesthesia (T0, after starting CO2 insuffation (T1, and at 60 (T2 and 120 minutes (T3 after insufflation. In all cases, the abdominal pressure was set at 15 mmHg. Complications were reported according to the Clavien-Dindo classification. Student's two–t-test, with a significance level set at pResults:The demographic characteristics of the patients in both groups were statistically comparable. Analysis of intra-operative anesthesiologic parameters showed that partial CO2 pressure during EP was significantly higher than during TP, with a consequent decrease in arterial pH. Other parameters analysed were similar in the two groups. Postoperative complications were comparable between groups. The most important limitations of this study were the small size of the patient groups and the impossibility of maintaining standard abdominal pressure throughout the operational phases, despite attempts to regulate it.Conclusions:This prospective randomized study demonstrates that, from the anesthesiologic viewpoint, during RARP the TP approach is preferable to EP, because of lower CO2 reabsorption and risk of acidosis.

  1. 'Trifecta' outcomes of robot-assisted partial nephrectomy in solitary kidney: a Vattikuti Collective Quality Initiative (VCQI) database analysis.

    Science.gov (United States)

    Arora, Sohrab; Abaza, Ronney; Adshead, James M; Ahlawat, Rajesh K; Challacombe, Benjamin J; Dasgupta, Prokar; Gandaglia, Giorgio; Moon, Daniel A; Yuvaraja, Thyavihally B; Capitanio, Umberto; Larcher, Alessandro; Porpiglia, Francesco; Porter, James R; Mottrie, Alexander; Bhandari, Mahendra; Rogers, Craig

    2018-01-01

    To analyse the outcomes of robot-assisted partial nephrectomy (RAPN) in patients with a solitary kidney in a large multi-institutional database. In all, 2755 patients in the Vattikuti Collective Quality Initiative database underwent RAPN by 22 surgeons at 14 centres in nine countries. Of these patients, 74 underwent RAPN with a solitary kidney between 2007 and 2016. We retrospectively analysed the functional and oncological outcomes of these 74 patients. A 'trifecta' of outcomes was assessed, with trifecta defined as a warm ischaemia time (WIT) of negative surgical margins, and no complications intraoperatively or within 3 months of RAPN. All 74 patients underwent RAPN successfully with one conversion to radical nephrectomy. The median (interquartile range [IQR]) operative time was 180 (142-230) min. Early unclamping was used in 11 (14.9%) patients and zero ischaemia was used in 12 (16.2%). Trifecta outcomes were achieved in 38 of 66 patients (57.6%). The median (IQR) WIT was 15.5 (8.75-20.0) min for the entire cohort. The overall complication rate was 24.1% and the rate of Clavien-Dindo grade ≤II complications was 16.3%. Positive surgical margins were present in four cases (5.4%). The median (IQR) follow-up was 10.5 (2.12-24.0) months. The median drop in estimated glomerular filtration rate at 3 months was 7.0 mL/min/1.72 m 2 (11.01%). Our findings suggest that RAPN is a safe and effective treatment option for select renal tumours in solitary kidneys in terms of a trifecta of negative surgical margins, WIT of <20 min, and low operative and perioperative morbidity. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  2. The perioperative outcomes between renal hilar and non-hilar tumors following robotic-assisted partial nephrectomy (RAPN).

    Science.gov (United States)

    Lu, Shih-Yen; Chung, Hsiao-Jen; Huang, Eric Yi-Hsiu; Lin, Tzu-Pin; Lin, Alex T L

    2018-03-15

    The aim of this study was to compare the perioperative outcomes between renal hilar tumors and non-hilar tumors after robotic-assisted partial nephrectomy (RAPN). A retrospective review of consecutive patients who underwent RAPN from December 2009 to September 2015 at our institution was recruited. Perioperative outcomes including demographic characteristics, perioperative, pathological and renal function outcomes were compared between the hilar group (n = 30) and non-hilar group (n = 170). In characteristics, hilar group was younger (52.4 vs. 58 years, p = 0.04) and had less body mass index (23.7 vs. 25.4 kg/m 2 , p = 0.018). Hilar group had larger tumor size (4.8 vs. 3.7 cm, p = 0.009), higher Preoperative Aspects and Dimensions Used for an Anatomical (PADUA) score (10.7 vs. 8.5, p Hilar tumor was associated with longer operative time (293.6 vs. 240.5 min, p = 0.001) and warm ischemia time (39.9 vs. 21.8 min, p hilar tumor patients had no difference of the change of creatinine and estimated glomerular filtration rate (eGFR) at postoperative 6 and 12 month as compared with non-hilar tumor patients. For renal hilar tumor, RAPN could provide acceptable results of perioperative, pathological and renal function outcome as compared with non-hilar tumor group. Thus RAPN is a safe and effective nephron-sparing surgery technique for renal hilar tumors. Copyright © 2018. Published by Elsevier Taiwan LLC.

  3. Immediate effects of a single session of robot-assisted gait training using Hybrid Assistive Limb (HAL) for cerebral palsy.

    Science.gov (United States)

    Matsuda, Mayumi; Mataki, Yuki; Mutsuzaki, Hirotaka; Yoshikawa, Kenichi; Takahashi, Kazushi; Enomoto, Keiko; Sano, Kumiko; Mizukami, Masafumi; Tomita, Kazuhide; Ohguro, Haruka; Iwasaki, Nobuaki

    2018-02-01

    [Purpose] Robot-assisted gait training (RAGT) using Hybrid Assistive Limb (HAL, CYBERDYNE) was previously reported beneficial for stroke and spinal cord injury patients. Here, we investigate the immediate effect of a single session of RAGT using HAL on gait function for cerebral palsy (CP) patients. [Subjects and Methods] Twelve patients (average age: 16.2 ± 7.3 years) with CP received a single session of RAGT using HAL. Gait speed, step length, cadence, single-leg support per gait cycle, hip and knee joint angle in stance, and swing phase per gait cycle were assessed before, during, and immediately after HAL intervention. [Results] Compared to baseline values, single-leg support per gait cycle (64.5 ± 15.8% to 69.3 ± 12.1%), hip extension angle in mid-stance (149.2 ± 19.0° to 155.5 ± 20.1°), and knee extension angle in mid-stance (137.6 ± 20.2° to 143.1 ± 19.5°) were significantly increased immediately after intervention. Further, the knee flexion angle in mid-swing was significantly decreased immediately after treatment (112.0 ± 15.5° to 105.2 ± 17.1°). Hip flexion angle in mid-swing also decreased following intervention (137.2 ± 14.6° to 129.7 ± 16.6°), but not significantly. Conversely, gait speed, step length, and cadence were unchanged after intervention. [Conclusion] A single-time RAGT with HAL improved single-leg support per gait cycle and hip and knee joint angle during gait, therapeutically improving gait function in CP patients.

  4. Open versus robotic-assisted transabdominal preperitoneal (R-TAPP) inguinal hernia repair: a multicenter matched analysis of clinical outcomes.

    Science.gov (United States)

    Gamagami, R; Dickens, E; Gonzalez, A; D'Amico, L; Richardson, C; Rabaza, J; Kolachalam, R

    2018-04-26

    To compare the perioperative outcomes of initial, consecutive robotic-assisted transabdominal preperitoneal (R-TAPP) inguinal hernia repair (IHR) cases with consecutive open cases completed by the same surgeons. Multicenter, retrospective, comparative study of perioperative results from open and robotic IHR using standard univariate and multivariate regression analyses for propensity score matched (1:1) cohorts. Seven general surgeons at six institutions contributed 602 consecutive open IHR and 652 consecutive R-TAPP IHR cases. Baseline patient characteristics in the unmatched groups were similar with the exception of previous abdominal surgery and all baseline characteristics were comparable in the matched cohorts. In matched analyses, postoperative complications prior to discharge were comparable. However, from post discharge through 30 days, fewer patients experienced complications in the R-TAPP group than in the open group [4.3% vs 7.7% (p = 0.047)]. The R-TAPP group had no reoperations post discharge through 30 days of follow-up compared with five patients (1.1%) in the open group (p = 0.062), respectively. Multivariate logistic regression analysis which demonstrated patient age > 65 years and the open approach were risk factors for complications within 30 days post discharge in the matched group [age > 65 years: odds ratio (OR) = 3.33 (95% CI 1.89, 5.87; p open approach: OR = 1.89 (95% CI 1.05, 3.38; p = 0.031)]. In this matched analysis, R-TAPP provides similar postoperative complications prior to discharge and a lower rate of postoperative complications through 30 days compared to open repair. R-TAPP is a promising and reproducible approach, and may facilitate adoption of minimally invasive repairs of inguinal hernias.

  5. Overground robot assisted gait trainer for the treatment of drug-resistant freezing of gait in Parkinson disease.

    Science.gov (United States)

    Pilleri, Manuela; Weis, Luca; Zabeo, Letizia; Koutsikos, Konstantinos; Biundo, Roberta; Facchini, Silvia; Rossi, Simonetta; Masiero, Stefano; Antonini, Angelo

    2015-08-15

    Freezing of Gait (FOG) is a frequent and disabling feature of Parkinson disease (PD). Gait rehabilitation assisted by electromechanical devices, such as training on treadmill associated with sensory cues or assisted by gait orthosis have been shown to improve FOG. Overground robot assisted gait training (RGT) has been recently tested in patients with PD with improvement of several gait parameters. We here evaluated the effectiveness of RGT on FOG severity and gait abnormalities in PD patients. Eighteen patients with FOG resistant to dopaminergic medications were treated with 15 sessions of RGT and underwent an extensive clinical evaluation before and after treatment. The main outcome measures were FOG questionnaire (FOGQ) global score and specific tasks for gait assessment, namely 10 meter walking test (10 MWT), Timed Up and Go test (TUG) and 360° narrow turns (360 NT). Balance was also evaluated through Fear of Falling Efficacy Scale (FFES), assessing self perceived stability and Berg Balance Scale (BBS), for objective examination. After treatment, FOGQ score was significantly reduced (P=0.023). We also found a significant reduction of time needed to complete TUG, 10 MWT, and 360 NT (P=0.009, 0.004 and 0.04, respectively). By contrast the number of steps and the number of freezing episodes recorded at each gait task did not change. FFES and BBS scores also improved, with positive repercussions on performance on daily activity and quality of life. Our results indicate that RGT is a useful strategy for the treatment of drug refractory FOG. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Blood Transfusion Requirement and Not Preoperative Anemia Are Associated with Perioperative Complications Following Intracorporeal Robot-Assisted Radical Cystectomy.

    Science.gov (United States)

    Tan, Wei Shen; Lamb, Benjamin W; Khetrapal, Pramit; Tan, Mae-Yen; Tan, Melanie El; Sridhar, Ashwin; Cervi, Elizabeth; Rodney, Simon; Busuttil, Gerald; Nathan, Senthil; Hines, John; Shaw, Greg; Mohammed, Anna; Baker, Hilary; Briggs, Timothy P; Klein, Andrew; Richards, Toby; Kelly, John D

    2017-02-01

    To assess the prevalence of preoperative anemia and the impact of preoperative anemia and blood transfusion requirement on 30- and 90-day complications in a cohort of patients undergoing robot-assisted radical cystectomy with intracorporeal urinary diversion (iRARC). IRARC was performed on 166 patients between June 2011 and March 2016. Prospective data were collected for patient demographics, clinical and pathologic characteristics, perioperative variables, transfusion requirements, and hospital length of stay. Thirty- and 90-day complications were classified according to the modified Memorial Sloan Kettering Cancer Center Clavien-Dindo system. Preoperative anemia was common (43.4%) and greatest in patients receiving neoadjuvant chemotherapy (48.6%) (p blood transfusion (p = 0.001). Blood transfusion required in 20.4% of patients with intraoperative and postoperative blood transfusion rate was 10.2% and 13.9%, respectively. The 30-day all complication rate and 30-day major complication rate were 55.4% and 15.7%, respectively, while 90-day all complication rate and 90-day major complication rate were 65.7% and 19.3%, respectively. Intraoperative blood transfusion was not associated with increased complications, but postoperative blood transfusion requirement was independently associated with perioperative morbidity: all 30-day complications (p = 0.003), all 90-day complications (p = 0.009), and 90-day major complications (p = 0.004). The presence of preoperative anemia in patients undergoing iRARC is not associated with increased surgical risk, although preoperative anemic patients were significantly more likely to require blood transfusion. Blood transfusion requirement and specifically postoperative blood transfusion are independently associated with perioperative morbidity and are an important factor for the optimization of postoperative outcomes.

  7. Comparative biomarker expression and RNA integrity in biospecimens derived from radical retropubic and robot-assisted laparoscopic prostatectomies.

    Science.gov (United States)

    Ricciardelli, Carmela; Bianco-Miotto, Tina; Jindal, Shalini; Dodd, Thomas J; Cohen, Penelope A; Marshall, Villis R; Sutherland, Peter D; Samaratunga, Hemamali; Kench, James G; Dong, Ying; Wang, Hong; Clements, Judith A; Risbridger, Gail P; Sutherland, Robert L; Tilley, Wayne D; Horsfall, David J

    2010-07-01

    Knowledge of preanalytic conditions that biospecimens are subjected to is critically important because novel surgical procedures, tissue sampling, handling, and storage might affect biomarker expression or invalidate tissue samples as analytes for some technologies. We investigated differences in RNA quality, gene expression by quantitative real-time PCR, and immunoreactive protein expression of selected prostate cancer biomarkers between tissues from retropubic radical prostatectomy (RRP) and robot-assisted laparoscopic prostatectomy (RALP). Sections of tissue microarray of 23 RALP and 22 RRP samples were stained with antibodies to androgen receptor (AR) and prostate-specific antigen (PSA) as intersite controls, and 14 other candidate biomarkers of research interest to three laboratories within the Australian Prostate Cancer BioResource tissue banking network. Quantitative real-time PCR was done for AR, PSA (KLK3), KLK2, KLK4, and HIF1A on RNA extracted from five RALP and five RRP frozen tissue cores. No histologic differences were observed between RALP and RRP tissue. Biomarker staining grouped these samples into those with increased (PSA, CK8/18, CKHMW, KLK4), decreased (KLK2, KLK14), or no change in expression (AR, ghrelin, Ki67, PCNA, VEGF-C, PAR2, YB1, p63, versican, and chondroitin 0-sulfate) in RALP compared with RRP tissue. No difference in RNA quality or gene expression was detected between RALP and RRP tissue. Changes in biomarker expression between RALP and RRP tissue exist at the immunoreactive protein level, but the etiology is unclear. Future studies should account for changes in biomarker expression when using RALP tissues, and mixed cohorts of RALP and RRP tissue should be avoided.

  8. Da Vinci Xi and Si platforms have equivalent perioperative outcomes during robot-assisted partial nephrectomy: preliminary experience.

    Science.gov (United States)

    Abdel Raheem, Ali; Sheikh, Abulhasan; Kim, Dae Keun; Alatawi, Atalla; Alabdulaali, Ibrahim; Han, Woong Kyu; Choi, Young Deuk; Rha, Koon Ho

    2017-03-01

    The aims of this study were to compare the perioperative outcomes of da Vinci Xi to Si during robotic-assisted partial nephrectomy (RAPN) and to discuss the feasibility of our novel port placement scheme for the da Vinci Xi platform, to overcome the existing kinetic and technical difficulties we faced with the linear port placement in patients with a small body habitus. A retrospective data analysis of patients who underwent RPN using da Vinci Xi (n = 18) was carried out. The outcomes of the Xi group were compared with the Si group (n = 18) selected using a case-matched methodology. For da Vinci Xi, we applied the universal linear port placement in 12 patients and our modified port placement in the remaining 6 patients. The Xi group had a shorter mean docking time of 17.8 ± 2.6 min compared to the Si group of 20.5 ± 2.1 min (p = 0.002); otherwise, no significant difference was present with regard to the remaining perioperative variables (p > 0.05). The modified Xi port placement had a shorter mean console time of 70.8 ± 9.7 min compared to the universal linear port placement of 89.3 ± 17.2 min (p = 0.03). Moreover, it provided a broader field of vision with excellent robotic arms movement, minimizing collisions and allowing an easier and comfortable surgical assist. Da Vinci Xi appears to be feasible and safe during RPN with similar outcomes to Si. The novel Xi port placement makes surgery easier in patients with low BMI.

  9. Learning curve of robot-assisted laparoscopic radical prostatectomy for a single experienced surgeon: comparison with simultaneous laparoscopic radical prostatectomy.

    Science.gov (United States)

    Ku, Ja Yoon; Ha, Hong Koo

    2015-04-01

    Despite the large number of analytical reports regarding the learning curve in the transition from open to robot-assisted radical prostatectomy (RARP), few comparative results with laparoscopic radical prostatectomy (LRP) have been reported. Thus, we evaluated operative and postoperative outcomes in RARP versus 100 simultaneously performed LRPs. A single surgeon had performed more than 1,000 laparoscopic operations, including 415 cases of radical nephrectomy, 85 radical cystectomies, 369 radical prostatectomies, and treatment of 212 other urological tumors, since 2009. We evaluated operative (operation time, intraoperative transfusion, complications, hospital stay, margin status, pathological stage, Gleason score) and postoperative (continence and erectile function) parameters in initial cases of RARP without tutoring compared with 100 recently performed LRPs. Mean operation time and length of hospital stay for RARP and LRP were 145.5±43.6 minutes and 118.1±39.1 minutes, and 6.4±0.9 days and 6.6±1.1 days, respectively (p=0.003 and p=0.721). After 17 cases, the mean operation time for RARP was similar to LRP (less than 2 hours). Positive surgical margins in localized cancer were seen in 11.1% and 8.9% of cases in RARP and LRP, respectively (p=0.733). At postoperative 3 months, sexual intercourse was reported in 14.0% and 12.0%, and pad-free continence in 96.0% and 81.0% in patients with RARP and LRP, respectively (p=0.796 and p=0.012). Previous large-volume experience of LRPs may shorten the learning curve for RARP in terms of oncological outcome. Additionally, previous experience with laparoscopy may improve the functional outcomes of RARP.

  10. The risk of urinary retention following robot-assisted radical prostatectomy and its impact on early continence outcomes.

    Science.gov (United States)

    Alnazari, Mansour; Zanaty, Marc; Ajib, Khaled; El-Hakim, Assaad; Zorn, Kevin C

    2017-12-22

    We aimed to evaluate the risk factors of acute urinary retention (AUR) following robot-assisted radical prostatectomy (RARP), as well as the relationship of AUR with early continence outcomes. The records of 740 consecutive patients who underwent RARP by two experienced surgeons at our institution were retrospectively reviewed from a prospectively collected database. Multiple factors, including age, body mass index (BMI), international prostate symptom score (IPSS), prostate volume, presence of median lobe, nerve preservation status, anastomosis time, and catheter removal time (Day 4 vs. 7), were evaluated as risk factors for AUR using univariate and multivariate analysis. The relation between AUR and early return of continence (one and three months) post-RARP was also evaluated. The incidence of clinically significant vesico-urethral anastomotic (VUA) leak and AUR following catheter removal were 0.9% and 2.2% (17/740), respectively. In men who developed AUR, there was no significant relationship with regards to age, BMI, IPSS, prostatic volume, median lobe, nerve preservation, or anastomosis time; however, the incidence of AUR was significantly higher for men with catheter removal at Day 4 (4.5% [16/351]) vs. Day 7 (0.2% [1/389]) (p=0.004). Moreover, patients with early removal of the catheter (Day 4) who developed AUR had an earlier one-month return of 0-pad continence 87.5% (14/16) compared to patients without AUR 45.6% (153/335), with no significant difference at three months. While AUR is an uncommon complication of RARP, its incidence is much higher than VUA leakage. Further, it is often not well-discussed during patient counselling preoperatively. Moreover, earlier return of urinary continence was observed in patients experiencing AUR following RARP exclusively with catheter removal at Day 4. Future studies are warranted to validate the long-term impact of AUR on continence outcomes.

  11. Robot-assisted radical prostatectomy has lower biochemical recurrence than laparoscopic radical prostatectomy: Systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Seon Heui Lee

    2017-05-01

    Full Text Available Purpose: To assess the effectiveness and safety of robot-assisted radical prostatectomy (RARP versus laparoscopic radical prostatectomy (LRP in the treatment of prostate cancer. Materials and Methods: Existing systematic reviews were updated to investigate the effectiveness and safety of RARP. Electronic databases, including Ovid MEDLINE, Ovid Embase, the Cochrane Library, KoreaMed, Kmbase, and others, were searched through July 2014. The quality of the selected systematic reviews was assessed by using the revised assessment of multiple systematic reviews (R-Amstar and the Cochrane Risk of Bias tool. Meta-analysis was performed by using Revman 5.2 (Cochrane Community and Comprehensive Meta-Analysis 2.0 (CMA; Biostat. Cochrane Q and I2 statistics were used to assess heterogeneity. Results: Two systematic reviews and 16 additional studies were selected from a search performed of existing systematic reviews. These included 2 randomized controlled clinical trials and 28 nonrandomized comparative studies. The risk of complications, such as injury to organs by the Clavien-Dindo classification, was lower with RARP than with LRP (relative risk [RR], 0.44; 95% confidence interval [CI], 1.23–0.85; p=0.01. The risk of urinary incontinence was lower (RR, 0.43; 95% CI, 0.31–0.60; p<0.000001 and the potency rate was significantly higher with RARP than with LRP (RR, 1.38; 95% CI, 1.11–1.70; I2 =78%; p=0.003. Regarding positive surgical margins, no significant difference in risk between the 2 groups was observed; however, the biochemical recurrence rate was lower after RARP than after LRP (RR, 0.59; 95% CI, 0.48–0.73; I2 =21%; p<0.00001. Conclusions: RARP appears to be a safe and effective technique compared with LRP with a lower complication rate, better potency, a higher continence rate, and a decreased rate of biochemical recurrence.

  12. Impact of robot-assisted spine surgery on health care quality and neurosurgical economics: A systemic review.

    Science.gov (United States)

    Fiani, Brian; Quadri, Syed A; Farooqui, Mudassir; Cathel, Alessandra; Berman, Blake; Noel, Jerry; Siddiqi, Javed

    2018-04-03

    Whenever any new technology is introduced into the healthcare system, it should satisfy all three pillars of the iron triangle of health care, which are quality, cost-effectiveness, and accessibility. There has been quite advancement in the field of spine surgery in the last two decades with introduction of new technological modalities such as CAN and surgical robotic devices. MAZOR SpineAssist/Renaissance was the first robotic system to be approved for the use in spine surgeries in the USA in 2004. In this review, the authors sought to determine if the current literature supports this technology to be cost-effective, accessible, and improve the quality of care for individuals and populations by increasing the likelihood of desired health outcomes. Robotic-assisted surgery seems to provide perfection in surgical ergonomics and surgical dexterity, consequently improving patient outcomes. A lot of data is present on the accuracy, effectiveness, and safety of the robotic-guided technology which reflects remarkable improvements in quality of care, making its utility convincingly undisputable. The technology has been claimed to be cost-effective but there seems to be lack of data in the literature on this topic to validate this claim. Apart from just the outcome parameters, there is an immense need of studies on real-time cost-efficacy, patient perspective, surgeon and resident learning curve, and their experience with this new technology. Furthermore, new studies looking into increased utilities of this technology, such as brain and spine tumor resection, deep brain stimulation procedures, and osteotomies in deformity surgery, might authenticate the cost of the equipment.

  13. Affective and Engagement Issues in the Conception and Assessment of a Robot-Assisted Psychomotor Therapy for Persons with Dementia

    Directory of Open Access Journals (Sweden)

    Natacha Rouaix

    2017-06-01

    Full Text Available The interest in robot-assisted therapies (RAT for dementia care has grown steadily in recent years. However, RAT using humanoid robots is still a novel practice for which the adhesion mechanisms, indications and benefits remain unclear. Also, little is known about how the robot's behavioral and affective style might promote engagement of persons with dementia (PwD in RAT. The present study sought to investigate the use of a humanoid robot in a psychomotor therapy for PwD. We examined the robot's potential to engage participants in the intervention and its effect on their emotional state. A brief psychomotor therapy program involving the robot as the therapist's assistant was created. For this purpose, a corpus of social and physical behaviors for the robot and a “control software” for customizing the program and operating the robot were also designed. Particular attention was given to components of the RAT that could promote participant's engagement (robot's interaction style, personalization of contents. In the pilot assessment of the intervention nine PwD (7 women and 2 men, M age = 86 y/o hospitalized in a geriatrics unit participated in four individual therapy sessions: one classic therapy (CT session (patient- therapist and three RAT sessions (patient-therapist-robot. Outcome criteria for the evaluation of the intervention included: participant's engagement, emotional state and well-being; satisfaction of the intervention, appreciation of the robot, and empathy-related behaviors in human-robot interaction (HRI. Results showed a high constructive engagement in both CT and RAT sessions. More positive emotional responses in participants were observed in RAT compared to CT. RAT sessions were better appreciated than CT sessions. The use of a social robot as a mediating tool appeared to promote the involvement of PwD in the therapeutic intervention increasing their immediate wellbeing and satisfaction.

  14. Acceptance, Prevalence and Indications for Robot-Assisted Laparoscopy - Results of a Survey Among Urologists in Germany, Austria and Switzerland.

    Science.gov (United States)

    Imkamp, Florian; Herrmann, Thomas R W; Tolkach, Yuri; Dziuba, Sebastian; Stolzenburg, Jens U; Rassweiler, Jens; Sulser, Tullio; Zimmermann, Uwe; Merseburger, Axel S; Kuczyk, Markus A; Burchardt, Martin

    2015-01-01

    Robotic-assisted laparoscopy (RAL) is being widely accepted in the field of urology as a replacement for conventional laparoscopy (CL). Nevertheless, the process of its integration in clinical routines has been rather spontaneous. To determine the prevalence of robotic systems (RS) in urological clinics in Germany, Austria and Switzerland, the acceptance of RAL among urologists as a replacement for CL and its current use for 25 different urological indications. To elucidate the practice patterns of RAL, a survey at hospitals in Germany, Austria and Switzerland was conducted. All surgically active urology departments in Germany (303), Austria (37) and Switzerland (84) received a questionnaire with questions related to the one-year period prior to the survey. The response rate was 63%. Among the participants, 43% were universities, 45% were tertiary care centres, and 8% were secondary care hospitals. A total of 60 RS (Germany 35, Austria 8, Switzerland 17) were available, and the majority (68%) were operated under public ownership. The perception of RAL and the anticipated superiority of RAL significantly differed between robotic and non-robotic surgeons. For only two urologic indications were more than 50% of the procedures performed using RAL: pyeloplasty (58%) and transperitoneal radical prostatectomy (75%). On average, 35% of robotic surgeons and only 14% of non-robotic surgeons anticipated RAL superiority in some of the 25 indications. This survey provides a detailed insight into RAL implementation in Germany, Austria and Switzerland. RAL is currently limited to a few urological indications with a small number of high-volume robotic centres. These results might suggest that a saturation of clinics using RS has been achieved but that the existing robotic capacities are being utilized ineffectively. The possible reasons for this finding are discussed, and certain strategies to solve these problems are offered. © 2015 S. Karger AG, Basel.

  15. A preliminary oncologic outcome and postoperative complications in patients undergoing robot-assisted radical cystectomy: Initial experience

    Directory of Open Access Journals (Sweden)

    Satoru Muto

    2017-05-01

    Full Text Available Purpose: Robot-assisted radical cystectomy (RARC was originally intended to replace open radical cystectomy (ORC as a minimally invasive surgery for patients with invasive bladder cancer. The purpose of this study was to evaluate the advantages of robotic surgery, comparing perioperative and oncologic outcomes between RARC and ORC. Materials and Methods: Between June 2012 and August 2016, 49 bladder cancer patients were given a radical cystectomy, 21 robotically and 28 by open procedure. We compared the clinical variables between the RARC and ORC groups. Results: In the RARC group, the median estimated blood loss (EBL during cystectomy, total EBL, operative time during cystectomy, and total operative time were 0 mL, 457.5 mL, 199 minutes, and 561 minutes, respectively. EBL during cystectomy (p<0.001, total EBL (p<0.001, and operative time during cystectomy (p=0.003 in the RARC group were significantly lower compared with the ORC group. Time to resumption of a regular diet (p<0.001 and length of stay (p=0.017 were also significantly shorter compared with the ORC group. However, total operative time in the RARC group (median, 561 minutes was significantly longer compared with the ORC group (median, 492.5 minutes; p=0.015. Conclusions: This Japanese study presented evidence that RARC yields benefits in terms of BL and time to regular diet, while consuming greater total operative time. RARC may be a minimally invasive surgical alternative to ORC with less EBL and shorter length of stay.

  16. Robotically Assisted Sonic Therapy as a Noninvasive Nonthermal Ablation Modality: Proof of Concept in a Porcine Liver Model.

    Science.gov (United States)

    Smolock, Amanda R; Cristescu, Mircea M; Vlaisavljevich, Eli; Gendron-Fitzpatrick, Annette; Green, Chelsey; Cannata, Jonathan; Ziemlewicz, Timothy J; Lee, Fred T

    2018-05-01

    Purpose To determine the feasibility of creating a clinically relevant hepatic ablation (ie, an ablation zone capable of treating a 2-cm liver tumor) by using robotically assisted sonic therapy (RAST), a noninvasive and nonthermal focused ultrasound therapy based on histotripsy. Materials and Methods This study was approved by the institutional animal use and care committee. Ten female pigs were treated with RAST in a single session with a prescribed 3-cm spherical treatment region and immediately underwent abdominal magnetic resonance (MR) imaging. Three pigs (acute group) were sacrificed immediately following MR imaging. Seven pigs (chronic group) were survived for approximately 4 weeks and were reimaged with MR imaging immediately before sacrifice. Animals underwent necropsy and harvesting of the liver for histologic evaluation of the ablation zone. RAST ablations were performed with a 700-kHz therapy transducer. Student t tests were performed to compare prescribed versus achieved ablation diameter, difference of sphericity from 1, and change in ablation zone volume from acute to chronic imaging. Results Ablation zones had a sphericity index of 0.99 ± 0.01 (standard deviation) (P < .001 vs sphericity index of 1). Anteroposterior and transverse dimensions were not significantly different from prescribed (3.4 ± 0.7; P = .08 and 3.2 ± 0.8; P = .29, respectively). The craniocaudal dimension was significantly larger than prescribed (3.8 ± 1.1; P = .04), likely because of respiratory motion. The central ablation zone demonstrated complete cell destruction and a zone of partial necrosis. A fibrous capsule surrounded the ablation zone by 4 weeks. On 4-week follow-up images, ablation zone volumes decreased by 64% (P < .001). Conclusion RAST is capable of producing clinically relevant ablation zones in a noninvasive manner in a porcine model. © RSNA, 2018.

  17. A process evaluation: does recruitment for an exercise program through ethnically specific channels and key figures contribute to its reach and receptivity in ethnic minority mothers?

    NARCIS (Netherlands)

    Hartman, Marieke A.; Nierkens, Vera; Cremer, Stephan W.; Stronks, Karien; Verhoeff, Arnoud P.

    2013-01-01

    Ethnic minority women from low-income countries who live in high-income countries are more physically inactive than ethnic majority women in those countries. At the same time, they can be harder to reach with health promotion programs. Targeting recruitment channels and execution to ethnic groups

  18. Robot-assisted radical prostatectomy: Multiparametric MR imaging-directed intraoperative frozen-section analysis to reduce the rate of positive surgical margins.

    Science.gov (United States)

    Petralia, Giuseppe; Musi, Gennaro; Padhani, Anwar R; Summers, Paul; Renne, Giuseppe; Alessi, Sarah; Raimondi, Sara; Matei, Deliu V; Renne, Salvatore L; Jereczek-Fossa, Barbara A; De Cobelli, Ottavio; Bellomi, Massimo

    2015-02-01

    To investigate whether use of multiparametric magnetic resonance (MR) imaging-directed intraoperative frozen-section (IFS) analysis during nerve-sparing robot-assisted radical prostatectomy reduces the rate of positive surgical margins. This retrospective analysis of prospectively acquired data was approved by an institutional ethics committee, and the requirement for informed consent was waived. Data were reviewed for 134 patients who underwent preoperative multiparametric MR imaging (T2 weighted, diffusion weighted, and dynamic contrast-material enhanced) and nerve-sparing robot-assisted radical prostatectomy, during which IFS analysis was used, and secondary resections were performed when IFS results were positive for cancer. Control patients (n = 134) matched for age, prostate-specific antigen level, and stage were selected from a pool of 322 patients who underwent nerve-sparing robot-assisted radical prostatectomy without multiparametric MR imaging and IFS analysis. Rates of positive surgical margins were compared by means of the McNemar test, and a multivariate conditional logistic regression model was used to estimate the odds ratio of positive surgical margins for patients who underwent MR imaging and IFS analysis compared with control subjects. Eighteen patients who underwent MR imaging and IFS analysis underwent secondary resections, and 13 of these patients were found to have negative surgical margins at final pathologic examination. Positive surgical margins were found less frequently in the patients who underwent MR imaging and IFS analysis than in control patients (7.5% vs 18.7%, P = .01). When the differences in risk factors are taken into account, patients who underwent MR imaging and IFS had one-seventh the risk of having positive surgical margins relative to control patients (adjusted odds ratio: 0.15; 95% confidence interval: 0.04, 0.61). The significantly lower rate of positive surgical margins compared with that in control patients provides

  19. Gastrointestinal stromal tumours of stomach: Robot-assisted excision with the da Vinci Surgical System regardless of size and location site.

    Science.gov (United States)

    Furbetta, Niccolo; Palmeri, Matteo; Guadagni, Simone; Di Franco, Gregorio; Gianardi, Desirée; Latteri, Saverio; Marciano, Emanuele; Moglia, Andrea; Cuschieri, Alfred; Di Candio, Giulio; Mosca, Franco; Morelli, Luca

    2018-03-23

    The role of minimally invasive surgery of gastrointestinal stromal tumours (GISTs) of the stomach remains uncertain especially for large and/or difficult located tumours. We are hereby presenting a single-centre series of robot-assisted resections using the da Vinci Surgical System (Si or Xi). Data of patients undergoing robot-assisted treatment of gastric GIST were retrieved from the prospectively collected institutional database and a retrospective analysis was performed. Patients were stratified according to size and location of the tumour. Difficult cases (DCs) were considered for size if tumour was> 50 mm and/or for location if the tumour was Type II, III or IV sec. Privette/Al-Thani classification. Between May 2010 and February 2017, 12 consecutive patients underwent robot-assisted treatment of GIST at our institution. DCs were 10/12 cases (83.3%), of which 6/10 (50%) for location, 2/10 (25%) for size and 2/10 (25%) for both. The da Vinci Si was used in 8 patients, of which 6 (75%) were DC, and the da Vinci Xi in 4, all of which (100%) were DC. In all patients, excision was by wedge resection. All lesions had microscopically negative resection margins. There was no conversion to open surgery, no tumour ruptures or spillage and no intraoperative complications. Our experience suggests a positive role of the robot da Vinci in getting gastric GIST removal with a conservative approach, regardless of size and location site. Comparative studies with a greater number of patients are necessary for a more robust assessment.

  20. Impact of tamsulosin on urinary retention following early catheter removal after robot-assisted laparoscopic radical prostatectomy: a prospective randomized controlled trial.

    Science.gov (United States)

    Jeong, In Gab; You, Dalsan; Yoon, Jong Hyun; Hong, Sungwoo; Lim, Ju Hyun; Hong, Jun Hyuk; Choo, Myung-Soo; Ahn, Hanjong; Kim, Choung-Soo

    2014-02-01

    To examine the impact of tamsulosin on the rate of acute urinary retention following early catheter removal after robot-assisted laparoscopic radical prostatectomy. A total of 236 patients who underwent robot-assisted laparoscopic radical prostatectomy for prostate cancer carried out by a single surgeon were enrolled in this randomized study. Patients were randomly divided into two groups: treatment with tamsulosin (0.4 mg) from 1 day before to 14 days after surgery (tamsulosin group), or no tamsulosin treatment (control group). The urethral catheter was removed on the fifth postoperative day. The primary end-point was the acute urinary retention rate. Changes in each domain of the International Continence Society male short-form questionnaire and uroflowmetry parameters were secondary end-points. The primary end-point was assessed in 218 patients (92.4%; n = 109 in each group). It was not assessed in 18 patients because of cystographic leak from the vesicourethral anastomosis. The acute urinary retention rate was lower in the tamsulosin group (7.3%) than in the control group (17.4%, P = 0.018). Multivariate logistic regression analysis identified tamsulosin treatment and the operative experience of the surgeon as independent risk factors for acute urinary retention. Tamsulosin-treated patients had a 0.30-fold lower risk of developing acute urinary retention compared with control patients (95% confidence interval 0.12-0.76; P = 0.011). None of the International Continence Society male questionnaire domain scores showed significant changes between the groups. Perioperative treatment with tamsulosin in patients undergoing robot-assisted laparoscopic radical prostatectomy reduces the rate of acute urinary retention after early catheter removal, without aggravating urinary incontinence. © 2013 The Japanese Urological Association.

  1. Comparison of robot-assisted versus conventional laparoscopic transperitoneal pyeloplasty for patients with ureteropelvic junction obstruction: a single-center study.

    Science.gov (United States)

    Bird, Vincent G; Leveillee, Raymond J; Eldefrawy, Ahmed; Bracho, Jorge; Aziz, Mohammed S

    2011-03-01

    To compare conventional laparoscopic pyeloplasty (C-LPP) and robotic-assisted laparoscopic pyeloplasty (RA-LPP), which are both used for correction of ureteropelvic junction obstruction. Robotic assistance may further expedite dissection and reconstruction; however it is unclear whether this has an impact on results. Between 1999 and 2009, 172 conventional or robotic-assisted transperitoneal laparoscopic pyeloplasties were performed by 2 surgeons. Data were obtained from our prospective database, patient charts, and radiographic reports. Statistical analysis was performed for the groups. A total of 98 patients underwent R-LPP, and 74 underwent C-LPP. Mean age, body mass index, and gender distribution were similar for the groups. Of the patients, 22 (12.8%) had secondary ureteropelvic junction obstruction. Operative time in minutes was 189.3 ± 62 for RA-LPP, and 186.6 ± 69 for C-LPP (P = .69) respectively. Intraoperative and postoperative complication rates for RA-LPP and C-LPP were 1%, 5.1% and 0, 2.7% (P = .83 and .85) respectively. There was no significant difference in mean suturing time: 48.3 ± 30 and 60 ± 46 (P = .30) for RA-LPP and C-LPP, respectively. Long-term follow up (minimum 6 months; available for 136 patients) showed 93.4% and 95% radiographic success rate based upon diuretic scintirenography for RA-LPP and C-LPP respectively. Operative time, perioperative outcome and success rates are similar for C-LPP and RA-LPP. Mean suturing time for RA-LPP was shorter; however, there was no significant time difference in total operative time. Complications for both procedures are infrequent. Success rates, as measured by diuretic scintirenography, are high for the 2 procedures. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Spontaneous Retroperitoneal Hemorrhage (Wunderlich Syndrome due to Large Upper Pole Renal Angiomyolipoma: Does Robotic-Assisted Laparoscopic Partial Nephrectomy Have a Role in Primary Treatment?

    Directory of Open Access Journals (Sweden)

    Achilles Ploumidis

    2013-01-01

    Full Text Available Spontaneous rapture with consequent retroperitoneal hemorrhage (Wunderlich’s syndrome is the complication mostly feared from large renal angiomyolipomas (RAMLs. In hemodynamic stable patients, minimal invasive therapies have superseded open surgery as the mainstay of treatment, with contemporary cases mostly treated by selective arterial embolization. Robotic-assisted laparoscopic partial nephrectomy (RALPN is an established minimal access treatment that has been used in the past for benign and malignant lesions of the kidney in the elective setting, but rarely in urgent situations as primary treatment. We present a case of a ruptured RAML in a young female treated effectively by RALPN.

  3. A comparative study of erectile function and use of erectile aids in high-risk prostate cancer patients after robot-assisted laparoscopic prostatectomy

    DEFF Research Database (Denmark)

    Østby-Deglum, Marie; Brennhovd, B.; Axcrona, K.

    2015-01-01

    Objective. Erectile function with and without use of erectile aids was compared in high-, intermediate- and low-risk prostate cancer patients at a mean of 3 years after robot-assisted laparoscopic prostatectomy (RALP). Materials and methods. A sample of 982 men who underwent RALP at Oslo University...... according to the preoperative D'Amico classification. Based on questionnaire data, two primary outcomes were defined: ability to have intercourse (sufficient erection), and use and effect of erectile aids. Results. Sufficient erection with or without erectile aids was reported by 19% of the high-, 30...

  4. Percutaneous Radiofrequency Ablation Versus Robotic-Assisted Partial Nephrectomy for the Treatment of Small Renal Cell Carcinoma

    International Nuclear Information System (INIS)

    Pantelidou, Maria; Challacombe, Ben; McGrath, Andrew; Brown, Matthew; Ilyas, Shahzad; Katsanos, Konstantinos; Adam, Andreas

    2016-01-01

    IntroductionThe authors compared the oncologic outcomes of radiofrequency ablation (RFA) with robotic-assisted partial nephrectomy (RPN) for the treatment of T1 stage renal cell carcinoma (RCC).Materials and methodsThis was a retrospective data analysis of a high-volume single tertiary centre. Patients were treated with RFA or RPN following multidisciplinary decision making. Only histologically proven RCCs were included. Baseline demographics were collected, and PADUA scores of tumour features were calculated to standardize baseline anatomy. Peri-operative complications, kidney function and oncological outcomes were compared.ResultsSixty-three cases were included in each group. Baseline renal function was poorer in RFA, and 16/63 RFA patients had tumours in single kidneys compared to 1/63 RPN cases (p < 0.001). Length of stay was shorter in RFA (1 vs. 3 days, p < 0.0001). Post-procedure renal function decline at 30 days was significantly less in RFA [(−0.8) ± 9.6 vs. (−16.1) ± 19.5 mls/min/1.73 m"2; p < 0.0001]. More minor complications were recorded in RPN (10/63 vs. 4/63, p = 0.15), but local recurrence was numerically higher in RFA (6/63 vs. 1/63, p = 0.11). Disease-free survival (DFS) was not significantly different (adjusted HR = 0.6, 95 % Cl 0.1–3.7; p = 0.60). Increasing tumour size was an independent predictor of local recurrence (adjusted HR = 1.7; 95 % Cl 1.1–2.6 per cm; p = 0.02).ConclusionsBoth RPN and RFA offer very good oncological outcomes for the treatment of T1 RCC with low peri-operative morbidity and similar oncologic outcomes. RFA demonstrated fewer peri-operative complications and better preservation of renal function, whereas RPN had an insignificantly lower local recurrence rate. RFA should be offered alongside RPN for selected cases.

  5. Percutaneous Radiofrequency Ablation Versus Robotic-Assisted Partial Nephrectomy for the Treatment of Small Renal Cell Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Pantelidou, Maria [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Challacombe, Ben [King’s Health Partners, Department of Urology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); McGrath, Andrew [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Brown, Matthew [King’s Health Partners, Department of Urology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Ilyas, Shahzad; Katsanos, Konstantinos, E-mail: konstantinos.katsanos@gstt.nhs.uk; Adam, Andreas [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom)

    2016-11-15

    IntroductionThe authors compared the oncologic outcomes of radiofrequency ablation (RFA) with robotic-assisted partial nephrectomy (RPN) for the treatment of T1 stage renal cell carcinoma (RCC).Materials and methodsThis was a retrospective data analysis of a high-volume single tertiary centre. Patients were treated with RFA or RPN following multidisciplinary decision making. Only histologically proven RCCs were included. Baseline demographics were collected, and PADUA scores of tumour features were calculated to standardize baseline anatomy. Peri-operative complications, kidney function and oncological outcomes were compared.ResultsSixty-three cases were included in each group. Baseline renal function was poorer in RFA, and 16/63 RFA patients had tumours in single kidneys compared to 1/63 RPN cases (p < 0.001). Length of stay was shorter in RFA (1 vs. 3 days, p < 0.0001). Post-procedure renal function decline at 30 days was significantly less in RFA [(−0.8) ± 9.6 vs. (−16.1) ± 19.5 mls/min/1.73 m{sup 2}; p < 0.0001]. More minor complications were recorded in RPN (10/63 vs. 4/63, p = 0.15), but local recurrence was numerically higher in RFA (6/63 vs. 1/63, p = 0.11). Disease-free survival (DFS) was not significantly different (adjusted HR = 0.6, 95 % Cl 0.1–3.7; p = 0.60). Increasing tumour size was an independent predictor of local recurrence (adjusted HR = 1.7; 95 % Cl 1.1–2.6 per cm; p = 0.02).ConclusionsBoth RPN and RFA offer very good oncological outcomes for the treatment of T1 RCC with low peri-operative morbidity and similar oncologic outcomes. RFA demonstrated fewer peri-operative complications and better preservation of renal function, whereas RPN had an insignificantly lower local recurrence rate. RFA should be offered alongside RPN for selected cases.

  6. Augmented-reality-based skills training for robot-assisted urethrovesical anastomosis: a multi-institutional randomised controlled trial.

    Science.gov (United States)

    Chowriappa, Ashirwad; Raza, Syed Johar; Fazili, Anees; Field, Erinn; Malito, Chelsea; Samarasekera, Dinesh; Shi, Yi; Ahmed, Kamran; Wilding, Gregory; Kaouk, Jihad; Eun, Daniel D; Ghazi, Ahmed; Peabody, James O; Kesavadas, Thenkurussi; Mohler, James L; Guru, Khurshid A

    2015-02-01

    To validate robot-assisted surgery skills acquisition using an augmented reality (AR)-based module for urethrovesical anastomosis (UVA). Participants at three institutions were randomised to a Hands-on Surgical Training (HoST) technology group or a control group. The HoST group was given procedure-based training for UVA within the haptic-enabled AR-based HoST environment. The control group did not receive any training. After completing the task, the control group was offered to cross over to the HoST group (cross-over group). A questionnaire administered after HoST determined the feasibility and acceptability of the technology. Performance of UVA using an inanimate model on the daVinci Surgical System (Intuitive Surgical Inc., Sunnyvale, CA, USA) was assessed using a UVA evaluation score and a Global Evaluative Assessment of Robotic Skills (GEARS) score. Participants completed the National Aeronautics and Space Administration Task Load Index (NASA TLX) questionnaire for cognitive assessment, as outcome measures. A Wilcoxon rank-sum test was used to compare outcomes among the groups (HoST group vs control group and control group vs cross-over group). A total of 52 individuals participated in the study. UVA evaluation scores showed significant differences in needle driving (3.0 vs 2.3; P = 0.042), needle positioning (3.0 vs 2.4; P = 0.033) and suture placement (3.4 vs 2.6; P = 0.014) in the HoST vs the control group. The HoST group obtained significantly higher scores (14.4 vs 11.9; P 0.012) on the GEARS. The NASA TLX indicated lower temporal demand and effort in the HoST group (5.9 vs 9.3; P = 0.001 and 5.8 vs 11.9; P = 0.035, respectively). In all, 70% of participants found that HoST was similar to the real surgical procedure, and 75% believed that HoST could improve confidence for carrying out the real intervention. Training in UVA in an AR environment improves technical skill acquisition with minimal cognitive demand. © 2014 The Authors. BJU International

  7. Evaluation of perioperative complications and outcomes of robot-assisted radical nephroureterectomy and bladder cuff excision in a tertiary center

    Directory of Open Access Journals (Sweden)

    Meng-Che Tai

    2018-01-01

    Full Text Available Purpose: For patients with localized upper tract urothelial carcinoma (UTUC, radical nephroureterectomy with ipsilateral bladder cuff excision (RNU + BCE is the standard treatment. In recent years, robot-assisted RNU with BCE (RaRNU + BCE has been another choice of surgical intervention. This article was aimed to analyze the efficacy and perioperative outcomes regarding RaRNU + BCE through a single institutional experience. Patients and Methods: From March 2012 to November 2015, a total of 54 patients with UTUC were treated with RaRNU + BCE at Taipei Veterans General Hospital. We collected demographic data, histopathological reports, perioperative complications, and oncologic outcomes. Results: A total of 54 patients were included in our study. The mean age was 71.9 ± 9.9 (range 48–88 and the mean body mass index was 23.5 ± 2.9 (range: 16.4–30.8. The mean operating time was 314 min (RaRNU: 133.9 ± 41.4 min and RaBCE: 72.9 ± 25.7 min. The mean first docking time was 26.8 ± 7.7 min and the mean second docking time was 16.5 ± 6.7 min. The mean EBL was 87.7 ml. Pathological stage distribution was 22.2%, 27.8%, 13.0%, 31.5%, and 5.6% in pTa, pT1, pT2, pT3, and pT4, respectively. Complications occurred in 7 cases (13%, with 4 Grade I and 3 Grade II by Clavien-Dindo classification. Positive tumor involvement at bladder cuff was noted in three patients, and the bladder recurrence rate was 29.6%. Local recurrence, lymph node metastasis, and distant metastasis were all noted for two patients, respectively. The cancer-specific and overall survival rate was 98.1% and 96.3%. Conclusions: Our experience showed that RaRNU + BCE is a technically feasible and safe procedure for selected patients with UTUC.

  8. Predicting target vessel location on robot-assisted coronary artery bypass graft using CT to ultrasound registration

    International Nuclear Information System (INIS)

    Cho, Daniel S.; Linte, Cristian; Chen, Elvis C. S.; Bainbridge, Daniel; Wedlake, Chris; Moore, John; Barron, John; Patel, Rajni; Peters, Terry

    2012-01-01

    Purpose: Although robot-assisted coronary artery bypass grafting (RA-CABG) has gained more acceptance worldwide, its success still depends on the surgeon's experience and expertise, and the conversion rate to full sternotomy is in the order of 15%-25%. One of the reasons for conversion is poor pre-operative planning, which is based solely on pre-operative computed tomography (CT) images. In this paper, the authors propose a technique to estimate the global peri-operative displacement of the heart and to predict the intra-operative target vessel location, validated via both an in vitro and a clinical study. Methods: As the peri-operative heart migration during RA-CABG has never been reported in the literatures, a simple in vitro validation study was conducted using a heart phantom. To mimic the clinical workflow, a pre-operative CT as well as peri-operative ultrasound images at three different stages in the procedure (Stage 0 --following intubation; Stage 1 --following lung deflation; and Stage 2 --following thoracic insufflation) were acquired during the experiment. Following image acquisition, a rigid-body registration using iterative closest point algorithm with the robust estimator was employed to map the pre-operative stage to each of the peri-operative ones, to estimate the heart migration and predict the peri-operative target vessel location. Moreover, a clinical validation of this technique was conducted using offline patient data, where a Monte Carlo simulation was used to overcome the limitations arising due to the invisibility of the target vessel in the peri-operative ultrasound images. Results: For the in vitro study, the computed target registration error (TRE) at Stage 0 , Stage 1 , and Stage 2 was 2.1, 3.3, and 2.6 mm, respectively. According to the offline clinical validation study, the maximum TRE at the left anterior descending (LAD) coronary artery was 4.1 mm at Stage 0 , 5.1 mm at Stage 1 , and 3.4 mm at Stage 2 . Conclusions: The authors

  9. Motor and psychosocial impact of robot-assisted gait training in a real-world rehabilitation setting: A pilot study.

    Directory of Open Access Journals (Sweden)

    Cira Fundarò

    Full Text Available In the last decade robotic devices have been applied in rehabilitation to overcome walking disability in neurologic diseases with promising results. Robot assisted gait training (RAGT using the Lokomat seems not only to improve gait parameters but also the perception of well-being. Data on the psychosocial patient-robot impact are limited, in particular in the real-world of RAGT, in the rehabilitation setting. During rehabilitation training, the Lokomat can be considered an "assistive device for movement". This allowed the use of the Psychosocial Impact of Assistive Device Scale- PIADS to describe patient interaction with the Lokomat. The primary aim of this pilot study was to evaluate the psychosocial impact of the Lokomat in an in-patient rehabilitation setting using the PIADS; secondary aims were to assess whether the psychosocial impact of RAGT is different between pathological sub-groups and if the Lokomat influenced functional variables (Functional Independence Measure scale-FIM and parameters provided by the Lokomat itself. Thirty-nine consecutive patients (69% males, 54.0±18.0 years eligible for Lokomat training, with etiologically heterogeneous walking disabilities (Parkinson's Disease, n = 10; Spinal Cord Injury, n = 21; Ictus Event, n = 8 were enrolled. Patients were assessed with the FIM before and after rehabilitation with Lokomat, and the PIADS was administered after the rehabilitative period with Lokomat. Overall the PIADS score was positive (35.8±21.6, as well as the three sub-scales, pertaining to "ability", "adaptability" and "self-esteem" (17.2±10.4, 8.9±5.5 and 10.1±6.6 respectively with no between-group differences. All patients significantly improved in gait measure and motor FIM scale (difference after-before treatment values: 11.7±9.8 and 11.2±10.3 respectively, increased treadmill speed (0.4 ± 0.2m/s, reduced body weight support (-14.0±9.5% and guidance force (-13.1 ± 10.7%. This pilot study indicates that

  10. Reaching the hard to reach.

    Science.gov (United States)

    Bhiwandi, P; Campbell, M; Potts, M

    1994-01-01

    The 1994 International Conference on Population and Development proposed increasing contraceptive couple protection from 550 million in 1995 to 880 million in 2015. The task for family planning (FP) programs is to provide access to services for, sometimes, inaccessible rural populations. FP need based on desire for no more children has ranged from under 20% in Senegal to almost 80% in Peru. Socioeconomic development was found not to be a prerequisite for fertility change. Gender inequalities in education and social autonomy must be changed. FP access is very important among women with a disadvantaged background or among women unsure about FP. Bangladesh is a good example of a country with increased contraceptive prevalence despite low income. The rule of thumb is that contraception increases of 15% contribute to a drop in family size of about one child. Program effectiveness is related to a variety of factors: contraceptive availability at many locations, acceptable price of contraception, delivery of the oral contraceptives without prescriptions, and other strategies. FP is a service not a medical treatment. A range of methods must be promoted and available from a range of facilities. Contraceptive use is dependent on the woman's stage in her lifecycle and is dependent on informed choice. Community-based distribution systems are effective, whereas free distribution by poorly-trained field workers is not always very effective because patient payment of all or part of the cost assures quality and freedom of choice. Effective programs for underprivileged groups involve aggressive, easy to manage programs that can be replicated rapidly. FP serves a useful function in depressing maternal mortality among the poor in Africa, who have no access to quality health services. Social marketing is an effective strategy for reaching remote areas. Political will and robust management are necessary commodities.

  11. Technique of Robotic-assisted Total Proctocolectomy with Lymphadenectomy and Ileal Pouch-Anal Anastomosis for Transverse Colitic Cancer of Ulcerative Colitis, Using the Single Cart Position.

    Science.gov (United States)

    Hanai, Tsunekazu; Maeda, Koutarou; Masumori, Koji; Katsuno, Hidetoshi; Matsuoka, Hiroshi

    2015-11-01

    Robotic surgery offers advantages for operating in a narrow space such as inside the pelvis. We report on the technique of robotic-assisted laparoscopic total proctocolectomy with lymphadenectomy and ileal pouch-anal anastomosis for ulcerative colitis with transverse colitic cancer, using the single cart position. A 46-year-old female patient was diagnosed with colitic cancer of the transverse colon during the surveillance of ulcerative colitis. Six port sites were used. Mobilization of the left-sided colon through to the rectum and mobilization of the transverse colon with lymphadenectomy around the middle colic artery were performed using the robotic surgical system. After rectal mobilization was conducted near the anus, the right side of the colon was mobilized and the ileum resected laparoscopically. Thereafter, a mucosectomy of the proctorectum was carried out through a trans-anal approach, and a hand-sewn J-pouch was performed. Finally, a diverting ileostomy was constructed through the right lower abdomen. The operative time was 460 minutes, including the console time of 361 minutes. The amount of blood loss was 76 g. The patient was discharged on postoperative day nine. Pathological results demonstrated that the depth of the lesion was T3, and the positive lymph node was 1 of 115 retrieved lymph nodes. There were no complications or mortality. Robotic-assisted total proctocolectomy and lymphadenectomy with ileal pouch-anal anastomosis for transverse colitic cancer of ulcerative colitis was performed safely using the single cart position.

  12. Effect of Robotic-Assisted vs Conventional Laparoscopic Surgery on Risk of Conversion to Open Laparotomy Among Patients Undergoing Resection for Rectal Cancer

    Science.gov (United States)

    Pigazzi, Alessio; Marshall, Helen; Croft, Julie; Corrigan, Neil; Copeland, Joanne; Quirke, Phil; West, Nick; Rautio, Tero; Thomassen, Niels; Tilney, Henry; Gudgeon, Mark; Bianchi, Paolo Pietro; Edlin, Richard; Hulme, Claire; Brown, Julia

    2017-01-01

    Importance Robotic rectal cancer surgery is gaining popularity, but limited data are available regarding safety and efficacy. Objective To compare robotic-assisted vs conventional laparoscopic surgery for risk of conversion to open laparotomy among patients undergoing resection for rectal cancer. Design, Setting, and Participants Randomized clinical trial comparing robotic-assisted vs conventional laparoscopic surgery among 471 patients with rectal adenocarcinoma suitable for curative resection conducted at 29 sites across 10 countries, including 40 surgeons. Recruitment of patients was from January 7, 2011, to September 30, 2014, follow-up was conducted at 30 days and 6 months, and final follow-up was on June 16, 2015. Interventions Patients were randomized to robotic-assisted (n = 237) or conventional (n = 234) laparoscopic rectal cancer resection, performed by either high (upper rectum) or low (total rectum) anterior resection or abdominoperineal resection (rectum and perineum). Main Outcomes and Measures The primary outcome was conversion to open laparotomy. Secondary end points included intraoperative and postoperative complications, circumferential resection margin positivity (CRM+) and other pathological outcomes, quality of life (36-Item Short Form Survey and 20-item Multidimensional Fatigue Inventory), bladder and sexual dysfunction (International Prostate Symptom Score, International Index of Erectile Function, and Female Sexual Function Index), and oncological outcomes. Results Among 471 randomized patients (mean [SD] age, 64.9 [11.0] years; 320 [67.9%] men), 466 (98.9%) completed the study. The overall rate of conversion to open laparotomy was 10.1%: 19 of 236 patients (8.1%) in the robotic-assisted laparoscopic group and 28 of 230 patients (12.2%) in the conventional laparoscopic group (unadjusted risk difference = 4.1% [95% CI, −1.4% to 9.6%]; adjusted odds ratio = 0.61 [95% CI, 0.31 to 1.21]; P = .16). The overall CRM+ rate was

  13. Demonstration of the Safety and Feasibility of Robotically Assisted Percutaneous Coronary Intervention in Complex Coronary Lesions: Results of the CORA-PCI Study (Complex Robotically Assisted Percutaneous Coronary Intervention).

    Science.gov (United States)

    Mahmud, Ehtisham; Naghi, Jesse; Ang, Lawrence; Harrison, Jonathan; Behnamfar, Omid; Pourdjabbar, Ali; Reeves, Ryan; Patel, Mitul

    2017-07-10

    The aims of this study were to evaluate the feasibility and technical success of robotically assisted percutaneous coronary intervention (R-PCI) for the treatment of coronary artery disease (CAD) in clinical practice, especially in complex lesions, and to determine the safety and clinical success of R-PCI compared with manual percutaneous coronary intervention (M-PCI). R-PCI is safe and feasible for simple coronary lesions. The utility of R-PCI for complex coronary lesions is unknown. All consecutive PCI procedures performed robotically (study group) or manually (control group) over 18 months were included. R-PCI technical success, defined as the completion of the procedure robotically or with partial manual assistance and without a major adverse cardiovascular event, was determined. Procedures ineligible for R-PCI (i.e., atherectomy, planned 2-stent strategy for bifurcation lesion, chronic total occlusion requiring hybrid approach) were excluded for analysis from the M-PCI group. Clinical success, defined as completion of the PCI procedure without a major adverse cardiovascular event, procedure time, stent use, and fluoroscopy time were compared between groups. A total of 315 patients (mean age 67.7 ± 11.8 years; 78% men) underwent 334 PCI procedures (108 R-PCIs, 157 lesions, 78.3% type B2/C; 226 M-PCIs, 336 lesions, 68.8% type B2/C). Technical success with R-PCI was 91.7% (rate of manual assistance 11.1%, rate of manual conversion 7.4%, rate of major adverse cardiovascular events 0.93%). Clinical success (99.1% with R-PCI vs. 99.1% with M-PCI; p = 1.00), stent use (stents per procedure 1.59 ± 0.79 with R-PCI vs. 1.54 ± 0.75 with M-PCI; p = 0.73), and fluoroscopy time (18.2 ± 10.4 min with R-PCI vs. 19.2 ± 11.4 min with M-PCI; p = 0.39) were similar between the groups, although procedure time was longer in the R-PCI group (44:30 ± 26:04 min:s vs. 36:34 ± 23:03 min:s; p = 0.002). Propensity-matched analysis confirmed that procedure time was longer

  14. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery.

    Science.gov (United States)

    KleinJan, Gijs H; van den Berg, Nynke S; de Jong, Jeroen; Wit, Esther M; Thygessen, Helene; Vegt, Erik; van der Poel, Henk G; van Leeuwen, Fijs W B

    2016-07-01

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green-(99m)Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green-(99m)Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs

  15. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery

    Energy Technology Data Exchange (ETDEWEB)

    KleinJan, Gijs H. [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Berg, Nynke S. van den [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); Jong, Jeroen de [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Pathology, Amsterdam (Netherlands); Wit, Esther M.; Poel, Henk G. van der [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); Thygessen, Helene [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Biostatistics, Amsterdam (Netherlands); Vegt, Erik [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Leeuwen, Fijs W.B. van [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Head and Neck Surgery and Oncology, Amsterdam (Netherlands)

    2016-07-15

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green-{sup 99m}Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green-{sup 99m}Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs

  16. Assessment of Robotic Console Skills (ARCS): construct validity of a novel global rating scale for technical skills in robotically assisted surgery.

    Science.gov (United States)

    Liu, May; Purohit, Shreya; Mazanetz, Joshua; Allen, Whitney; Kreaden, Usha S; Curet, Myriam

    2018-01-01

    Skill assessment during robotically assisted surgery remains challenging. While the popularity of the Global Evaluative Assessment of Robotics Skills (GEARS) has grown, its lack of discrimination between independent console skills limits its usefulness. The purpose of this study was to evaluate construct validity and interrater reliability of a novel assessment designed to overcome this limitation. We created the Assessment of Robotic Console Skills (ARCS), a global rating scale with six console skill domains. Fifteen volunteers who were console surgeons for 0 ("novice"), 1-100 ("intermediate"), or >100 ("experienced") robotically assisted procedures performed three standardized tasks. Three blinded raters scored the task videos using ARCS, with a 5-point Likert scale for each skill domain. Scores were analyzed for evidence of construct validity and interrater reliability. Group demographics were indistinguishable except for the number of robotically assisted procedures performed (p = 0.001). The mean scores of experienced subjects exceeded those of novices in dexterity (3.8 > 1.4, p  1.8, p  2.2, p  1.9, p = 0.001), and force sensitivity (4.3 > 2.6, p  1.4, p = 0.002), field of view (2.8 > 1.8, p = 0.021), instrument visualization (3.2 > 2.2, p = 0.045), manipulator workspace (3.1 > 1.9, p = 0.004), and force sensitivity (3.7 > 2.6, p = 0.033). The mean scores of experienced subjects exceeded those of intermediates in dexterity (3.8 > 2.8, p = 0.003), field of view (4.1 > 2.8, p  3.2, p = 0.044). Rater agreement in each domain demonstrated statistically significant concordance (p skills plateau faster than others. Therefore, ARCS may be more useful than GEARS to evaluate distinct console skills. Future studies will examine why some domains did not adequately differentiate between subjects and applications for intraoperative use.

  17. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery

    International Nuclear Information System (INIS)

    KleinJan, Gijs H.; Berg, Nynke S. van den; Jong, Jeroen de; Wit, Esther M.; Poel, Henk G. van der; Thygessen, Helene; Vegt, Erik; Leeuwen, Fijs W.B. van

    2016-01-01

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green- 99m Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green- 99m Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs were

  18. Evolution of robot-assisted orthotopic ileal neobladder formation: a step-by-step update to the University of Southern California (USC) technique.

    Science.gov (United States)

    Chopra, Sameer; de Castro Abreu, Andre Luis; Berger, Andre K; Sehgal, Shuchi; Gill, Inderbir; Aron, Monish; Desai, Mihir M

    2017-01-01

    To describe our, step-by-step, technique for robotic intracorporeal neobladder formation. The main surgical steps to forming the intracorporeal orthotopic ileal neobladder are: isolation of 65 cm of small bowel; small bowel anastomosis; bowel detubularisation; suture of the posterior wall of the neobladder; neobladder-urethral anastomosis and cross folding of the pouch; and uretero-enteral anastomosis. Improvements have been made to these steps to enhance time efficiency without compromising neobladder configuration. Our technical improvements have resulted in an improvement in operative time from 450 to 360 min. We describe an updated step-by-step technique of robot-assisted intracorporeal orthotopic ileal neobladder formation. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  19. Robot-assisted laparoscopic adenomyomectomy of adenomyotic nodule implanted in the uterine endometrium manifesting as endometrial cancer: a case report and literature review.

    Science.gov (United States)

    Jeon, J H; Jeong, K; Moon, H S

    2017-01-01

    Thickened uterine endometrium with abnormal uterine bleeding highly suggests endometrial hyperplasia or endometrial carcinoma. A case of 35-year-old nulliparous woman came to our department with endometrial mass manifesting as endometrial cancer. Transrectal ultrasonography and magnetic resonance imaging (MRI) showed an 8x6 cm multicystic, ill-defined mass compacted at the uterine endometrium, the anterior wall of the uterus, and 3x3 cm heterogenous mass at the left adnexa. The edometrial mass showed multiple septations with enhancement and low-signal intensity on T2-weighted images. After endometrial biopsy was done and simple hyperplasia without atypia was observed at the histopathologic finding, the patient underwent robot-assisted laparoscopy and diagnosed as adenomyoma at the frozen pathology. After adenomyomectomy, permanent pathologic analysis revealed the same result and she recovered without any complications and responded well to gonadotropin-releasing hormone (GnRH) agonist therapy.

  20. Robot-assisted remote echocardiographic examination and teleconsultation: a randomized comparison of time to diagnosis with standard of care referral approach.

    Science.gov (United States)

    Boman, Kurt; Olofsson, Mona; Berggren, Peter; Sengupta, Partho P; Narula, Jagat

    2014-08-01

    The strategy using cardiological consultation in addition to the robot-assisted remote echocardiography at a distance was tested in a prospective, randomized open-label trial to evaluate its feasibility and to define its clinical value in a rural area. The present study involved 1 primary healthcare center in the north of Sweden, 135 miles from the hospital where the echocardiograms and the cardiology teleconsultation were performed long distance in real time. Nineteen patients were randomized to remote consultation and imaging, and 19 to the standard of care consultation. The total process time was significantly reduced in the former arm (median 114 days vs. 26.5 days; p healthcare center. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.