WorldWideScience

Sample records for rise time measurements

  1. Neutron spectrum measurement using rise-time discrimination method

    International Nuclear Information System (INIS)

    Luo Zhiping; Suzuki, C.; Kosako, T.; Ma Jizeng

    2009-01-01

    PSD method can be used to measure the fast neutron spectrum in n/γ mixed field. A set of assemblies for measuring the pulse height distribution of neutrons is built up,based on a large volume NE213 liquid scintillator and standard NIM circuits,through the rise-time discrimination method. After that,the response matrix is calculated using Monte Carlo method. The energy calibration of the pulse height distribution is accomplished using 60 Co radioisotope. The neutron spectrum of the mono-energetic accelerator neutron source is achieved by unfolding process. Suggestions for further improvement of the system are presented at last. (authors)

  2. Measures to reduce construction time of high-rise buildings

    Science.gov (United States)

    Kolchedantsev, Leonid; Adamtsevich, Aleksey; Stupakova, Olga; Drozdov, Alexander

    2018-03-01

    The organizational and technological solutions for high-rise buildings construction efficiency increase are considered, primarily - decrease of typical floor construction time and improvement of bearing structures concrete quality. The essence of offered technology is: a concrete mixing station and a polygon mainly for load-bearing wall panels with starter bars casting are located on the building site; for reinforced concrete components manufacturing and butt joints grouting the warmed-up concrete mixtures are used. The results of researches and elaborations carried out by the SPSUACE in area of a preliminary warming-up of concrete mixtures are presented. The possibility and feasibility of their usage in high-rise buildings and of excess height buildings construction including cast-in-place and precast execution are shown. The essence of heat-vibro treating of concrete mixture is revealed as a kind of prior electroresistive curing, and the achieved results are: accelerated concrete strength gain, power inputs decrease, concrete quality improvement. It is shown that the location of a concrete mixing station on the building site enables to broaden possibilities of the "thermos" method use and to avoid concrete mixtures warming up in medium-mass structures erection (columns, girders) during the high-rise buildings construction. It is experimentally proved that the splice between precast elements encased with warmed-up concrete mixture is equal with conjugated elements in strength.

  3. Measurement of the Rise-Time in a Single Sided Ladder Detector

    International Nuclear Information System (INIS)

    Gerber, C.E.

    1997-01-01

    In this note we report on the measurement of the preamplifier output rise time for a SVXII chip mounted on a D0 single sided ladder. The measurements were performed on the ladder 001-883-L, using the laser test stand of Lab D. The rise time was measured for different values of the response (or bandwidth) of the preamplifier. As a bigger bandwidth results in longer rise times and therefore in less noise, the largest possible bandwidth consistent with the time between bunch crossings should be chosen to operate the detectors. The rise time is defined as the time elapsed between 10% and 90% of the charge is collected. It is also interesting to measure the time for full charge collection and the percentage of charge collected in 132 ns and 396 ns. The results are shown in table 1, for bandwidths between 2 and 63 (binary numbers). The uncertainty on the time measurement is considered to be ∼ 10 ns. Figure 1 schematically defines the four quantities measured: rise time, time of full charge collection, and percentage of charge collected in 132 ns and 396 ns. Figures 2 to 8 are the actual measurements for bandwidths of 2, 4, 8, 12, 24, 32 and 63. Figure 9 is a second measurement for BW=24, used as a consistency check of the system and the time measurement performed on the plots. The data indicate that the single sided ladders can be operated at BW=63 for 396 ns and BW=12 for 132 ns, achieving full charge collection. This will result in smaller noise than originally anticipated.

  4. Measuring the diameter of rising gas bubbles by means of the ultrasound transit time technique

    Energy Technology Data Exchange (ETDEWEB)

    Richter, T., E-mail: Thomas.Richter6@tu-dresden.de; Eckert, K., E-mail: Kerstin.Eckert@tu-dresden.de; Yang, X.; Odenbach, S.

    2015-09-15

    Highlights: • Ultrasound transit time technique (UTTT) is applied to the zig-zag raise of gas bubble. • Comparison of bubble diameter and tilt, measured by UTTT, with high-speed imaging. • Uncertainty in the determination of the bubble diameter by UTTT is less than 7%. • UTTT is able to measure dynamic changes in bubble size in opaque liquids and vessels. • UTTT can be applied to liquid metal loops. - Abstract: This study presents ultrasound transit time technique (UTTT) measurements of the diameter variations of single argon bubbles rising in a zig-zag trajectory in water. Simultaneous size measurements with a high-speed camera show that UTTT resolves both the apparent diameter and the tilt of the bubble axis with an accuracy of better than 7%. This qualifies UTTT for the measurement of bubble sizes in opaque liquids, such as liquid metals, or vessels.

  5. Measuring Sea Level Rise-Induced Shoreline Changes and Inundation in Real Time

    Science.gov (United States)

    Shilling, F.; Waetjen, D.; Grijalva, E.

    2016-12-01

    We describe a method to monitor shoreline inundation and changes in response to sea level rise (SLR) using a network of time-lapse cameras. We found for coastal tidal marshes that this method was sensitive to vertical changes in sea level of 20 cm has occurred in the San Francisco Bay and other US coastal areas and is likely to rise by another 30-45 cm by mid-century, which will flood and erode many coastal ecosystems, highways, and urban areas. This rapid degree of rise means that it is imperative to co-plan for natural and built systems. Many public facilities are adjacent to shoreline ecosystems, which both protect infrastructure from wave and tide energy and are home to regulated species and habitats. Accurate and timely information about the actual extent of SLR impacts to shorelines will be critical during built-system adaptation. Currently, satellite-sourced imagery cannot provide the spatial or temporal resolution necessary to investigate fine-scale shoreline changes, leaving a gap between predictive models and knowing how, where and when these changes are occurring. The method described is feasible for near-term (1 to 10 years) to long-term application and can be used for measuring fine-resolution shoreline changes (organize photographs that could be combined with related external data (e.g., gauged water levels) to create an information mashup. This information could be used to validate models predicting shoreline inundation and loss, inform SLR-adaptation planning, and to visualize SLR impacts to the public.

  6. Relativistic rise measurement by cluster counting method in time expansion chamber

    International Nuclear Information System (INIS)

    Rehak, P.; Walenta, A.H.

    1979-10-01

    A new approach to the measurement of the ionization energy loss for the charged particle identification in the region of the relativistic rise was tested experimentally. The method consists of determining in a special drift chamber (TEC) the number of clusters of the primary ionization. The method gives almost the full relativistic rise and narrower landau distribution. The consequences for a practical detector are discussed

  7. Compton suppression through rise-time analysis

    International Nuclear Information System (INIS)

    Selvi, S.; Celiktas, C.

    2007-01-01

    We studied Compton suppression for 60 Co and 137 Cs radioisotopes using a signal selection criterion based on contrasting the fall time of the signals composing the photo peak with those composing the Compton continuum. The fall time criterion is employed by using the pulse shape analysis observing the change in the fall times of the gamma-ray pulses. This change is determined by measuring the changes in the rise times related to the fall time of the scintillator and the timing signals related to the fall time of the input signals. We showed that Compton continuum suppression is achieved best via the precise timing adjustment of an analog rise-time analyzer connected to a NaI(Tl) scintillation spectrometer

  8. Plume rise measurements at Turbigo

    Energy Technology Data Exchange (ETDEWEB)

    Anfossi, D

    1982-01-01

    This paper presents analyses of plume measurements obtained during that campaign by the ENEL ground-based Lidar. The five stacks of Turbigo Power Plant have different heights and emission parameters and their plumes usually combine, so a model for multiple sources was used to predict the plume rises. These predictions are compared with the observations. Measurements of sigma/sub v/ and sigma/sub z/ over the first 1000 m are compared with the curves derived from other observations in the Po Valley, using the no-lift balloon technique over the same range of downwind distance. Skewness and kurtosis distributions are shown, both along the vertical and the horizontal directions. In order to show the plume structure in more detail, we present two examples of Lidar-derived cross sections and the corresponding vertically and horizontally integrated concentration profiles.

  9. Interconnect rise time in superconducting integrating circuits

    International Nuclear Information System (INIS)

    Preis, D.; Shlager, K.

    1988-01-01

    The influence of resistive losses on the voltage rise time of an integrated-circuit interconnection is reported. A distribution-circuit model is used to present the interconnect. Numerous parametric curves are presented based on numerical evaluation of the exact analytical expression for the model's transient response. For the superconducting case in which the series resistance of the interconnect approaches zero, the step-response rise time is longer but signal strength increases significantly

  10. Microfossil measures of rapid sea-level rise: Timing of response of two microfossil groups to a sudden tidal-flooding experiment in Cascadia

    Science.gov (United States)

    Horton, B.P.; Milker, Yvonne; Dura, T.; Wang, Kelin; Bridgeland, W.T.; Brophy, Laura S.; Ewald, M.; Khan, Nicole; Engelhart, S.E.; Nelson, Alan R.; Witter, Robert C.

    2017-01-01

    Comparisons of pre-earthquake and post-earthquake microfossils in tidal sequences are accurate means to measure coastal subsidence during past subduction earthquakes, but the amount of subsidence is uncertain, because the response times of fossil taxa to coseismic relative sea-level (RSL) rise are unknown. We measured the response of diatoms and foraminifera to restoration of a salt marsh in southern Oregon, USA. Tidal flooding following dike removal caused an RSL rise of ∼1 m, as might occur by coseismic subsidence during momentum magnitude (Mw) 8.1–8.8 earthquakes on this section of the Cascadia subduction zone. Less than two weeks after dike removal, diatoms colonized low marsh and tidal flats in large numbers, showing that they can record seismically induced subsidence soon after earthquakes. In contrast, low-marsh foraminifera took at least 11 months to appear in sizeable numbers. Where subsidence measured with diatoms and foraminifera differs, their different response times may provide an estimate of postseismic vertical deformation in the months following past megathrust earthquakes.

  11. Rise time spectroscopy in cadmium telluride detectors

    International Nuclear Information System (INIS)

    Scharager, Claude; Siffert, Paul; Carnet, Bernard; Le Meur, Roger.

    1980-11-01

    By a simultaneous analysis of rise time and pulse amplitude distributions of the signals issued from various cadmium telluride detectors, it is possible to obtain informations about surface and bulk trapping, field distribution within the detectors, as well as charge collection and transport properties. These investigations have been performed on both pure and chlorine doped and materials for various surfaces preparation conditions [fr

  12. Rugged calorimeter with a fast rise time

    International Nuclear Information System (INIS)

    McMurtry, W.M.; Dolce, S.R.

    1980-01-01

    An intrinsic 1-mil-thick gold foil calorimeter has been developed which rises to 95% of the energy deposited in less than 2 microseconds. This calorimeter is very rugged, and can withstand rough handling without damage. The time constant is long, in the millisecond range, because of its unique construction. Use of this calorimeter has produced 100% data recovery, and agreement with true deposition to less than 10%

  13. THE RISE TIME OF NORMAL AND SUBLUMINOUS TYPE Ia SUPERNOVAE

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Gaitan, S.; Perrett, K.; Carlberg, R. [Department of Astronomy and Astrophysics, University of Toronto, 50 St. george Street, Toronto, ON M5S 3H4 (Canada); Conley, A. [Center for Astrophysics and Space Astronomy, University of Colorado, 593 UCB, Boulder, CO 80309-0593 (United States); Bianco, F. B.; Howell, D. A.; Graham, M. L. [Department of Physics, University of California, Santa Barbara, Broida Hall, Mail Code 9530, Santa Barbara, CA 93106-9530 (United States); Sullivan, M.; Hook, I. M. [Department of Physics (Astrophysics), University of Oxford, DWB, Keble Road, Oxford, OX1 3RH (United Kingdom); Astier, P.; Balland, C.; Fourmanoit, N.; Guy, J.; Hardin, D.; Pain, R. [LPNHE, Universite Pierre et Marie Curie Paris 6, Universite Paris Diderot Paris 7, CNRS-IN2P3, 4 Place Jussieu, 75252 Paris Cedex 05 (France); Balam, D. [Dominion Astrophysical Observatory, Herzberg Institute of Astrophysics, 5071 West Saanich Road, Victoria, BC V9E 2E7 (Canada); Basa, S. [Laboratoire d' Astrophysique de Marseille, Pole de l' Etoile Site de Chateau-Gombert, 38, rue Frederic Joliot-Curie, 13388 Marseille cedex 13 (France); Fouchez, D. [CPPM, CNRS-IN2P3 and University Aix Marseille II, Case 907, 13288 Marseille cedex 9 (France); Lidman, C. [Australian Astronomical Observatory, P.O. Box 296, Epping, NSW 1710 (Australia); Palanque-Delabrouille, N., E-mail: gonzalez@astro.utoronto.ca [DSM/IRFU/SPP, CEA-Saclay, F-91191 Gif-sur-Yvette (France); and others

    2012-01-20

    We calculate the average stretch-corrected rise time of Type Ia supernovae (SNe Ia) in the Supernova Legacy Survey. We use the aggregate light curves of spectroscopic and photometrically identified SNe Ia to fit the rising part of the light curve with a simple quadratic model. We obtain a light curve shape corrected, i.e., stretch-corrected, fiducial rise time of 17.02{sup +0.18}{sub -0.28} (stat) days. The measured rise time differs from an earlier finding by the SNLS (Conley et al.) due to the use of different SN Ia templates. We compare it to nearby samples using the same methods and find no evolution in the early part of the light curve of SNe Ia up to z = 1. We search for variations among different populations, particularly subluminous objects, by dividing the sample in stretch. Bright and slow decliners (s > 1.0) have consistent stretch-corrected rise times compared to fainter and faster decliners (0.8 < s {<=} 1.0); they are shorter by 0.57{sup +0.47}{sub -0.50} (stat) days. Subluminous SNe Ia (here defined as objects with s {<=} 0.8), although less constrained, are also consistent, with a rise time of 18.03{sup +0.81}{sub -1.37} (stat) days. We study several systematic biases and find that the use of different fiducial templates may affect the average rise time but not the intrinsic differences between populations. Based on our results, we estimate that subluminous SNe Ia are powered by 0.05-0.35 M{sub Sun} of {sup 56}Ni synthesized in the explosion. Our conclusions are the same for the single-stretch and two-stretch parameterizations of the light curve.

  14. Subnanosecond-rise-time, low-impedance pulse generator

    International Nuclear Information System (INIS)

    Druce, R.; Vogtlin, G.

    1983-01-01

    This paper describes a fast rise, low-impedance pulse generator that has been developed at the Lawrence Livermore National Laboratory. The design specifications of this generator are: 50-kV operating voltage, 1-ohm output impedance, subnanosecond rise time, and a 2 to 10 nanosecond pulse length. High repetition rate is not required. The design chosen is a parallel-plate, folded Blumlein generator. A tack switch is utilized for its simple construction and high performance. The primary diagnostic is a capacitive voltage divider with a B probe used to measure the current waveform

  15. Subnanosecond-rise-time, low-impedance pulse generator

    Energy Technology Data Exchange (ETDEWEB)

    Druce, R.; Vogtlin, G.

    1983-06-03

    This paper describes a fast rise, low-impedance pulse generator that has been developed at the Lawrence Livermore National Laboratory. The design specifications of this generator are: 50-kV operating voltage, 1-ohm output impedance, subnanosecond rise time, and a 2 to 10 nanosecond pulse length. High repetition rate is not required. The design chosen is a parallel-plate, folded Blumlein generator. A tack switch is utilized for its simple construction and high performance. The primary diagnostic is a capacitive voltage divider with a B probe used to measure the current waveform.

  16. Subnanosecond-rise-time, low-impedance pulse generator

    Science.gov (United States)

    Druce, R.; Vigtlin, G.

    1983-06-01

    A fast rise, low impedance pulse generator developed at the Lawrence Livermore National Laboratory is described. The design specifications of this generator are: 50-kV operating voltage, 1-ohm output impedance, subnanosecond rise time, and a 2 to 10 nanosecond pulse length. High repetition rate is not required. The design chosen is a parallel plate, folded Blumlein generator. A tack switch is utilized for its simple construction and high performance. The primary diagnostic is a capacitive voltage divider with a B probe used to measure the current waveform.

  17. submitter Measurement of intrinsic rise times for various L(Y)SO and LuAG scintillators with a general study of prompt photons to achieve 10 ps in TOF-PET

    CERN Document Server

    Gundacker, Stefan; Pauwels, Kristof; Lecoq, Paul

    2016-01-01

    The coincidence time resolution (CTR) of scintillator based detectors commonly used in positron emission tomography is well known to be dependent on the scintillation decay time (${{\\tau}_{d}}$ ) and the number of photons detected (${{n}^{\\prime}}$ ), i.e. $CTR\\propto \\sqrt{{{\\tau}_{d}}/{{n}^{\\prime}}}$ . However, it is still an open question to what extent the scintillation rise time (${{\\tau}_{r}}$ ) and other fast or prompt photons, e.g. Cherenkov photons, at the beginning of the scintillation process influence the CTR. This paper presents measurements of the scintillation emission rate for different LSO type crystals, i.e. LSO:Ce, LYSO:Ce, LSO:Ce codoped Ca and LGSO:Ce. For the various LSO-type samples measured we find an average value of 70 ps for the scintillation rise time, although some crystals like LSO:Ce codoped Ca seem to have a much faster rise time in the order of 20 ps. Additional measurements for LuAG:Ce and LuAG:Pr show a rise time of 535 ps and 251 ps, respectively. For these crystals, promp...

  18. Fast rise times and the physical mechanism of deep earthquakes

    Science.gov (United States)

    Houston, H.; Williams, Q.

    1991-01-01

    A systematic global survey of the rise times and stress drops of deep and intermediate earthquakes is reported. When the rise times are scaled to the seismic moment release of the events, their average is nearly twice as fast for events deeper than about 450 km as for shallower events.

  19. Chinas Rise: A Time for Choosing

    Science.gov (United States)

    2012-06-01

    use of small surrogate or proxy wars since 1945 to prove their theory. However, sixty-seven years of history is statistically insignificant, given...knowledge this would now be a measure too late, only slowing their growth and possibly doing as much (or more) harm domestically and internationally as...were born from the same mother . Despite a century and a quarter of disputes, there still remained much that was similar between them. Once

  20. 'Stutter timing' for charge decay time measurement

    International Nuclear Information System (INIS)

    Chubb, John; Harbour, John; Pavey, Ian

    2011-01-01

    The paper describes the approach of 'stutter timing' that has been developed to improve the accuracy of measuring charge decay times in the presence of noise in compact and portable charge decay test instrumentation. The approach involves starting and stopping the timing clock as the noisy signal rises above and falls below the target threshold voltage level.

  1. Relativistic rise measurements with very fine sampling intervals

    International Nuclear Information System (INIS)

    Ludlam, T.; Platner, E.D.; Polychronakos, V.A.; Lindenbaum, S.J.; Kramer, M.A.; Teramoto, Y.

    1980-01-01

    The motivation of this work was to determine whether the technique of charged particle identification via the relativistic rise in the ionization loss can be significantly improved by virtue of very small sampling intervals. A fast-sampling ADC and a longitudinal drift geometry were used to provide a large number of samples from a single drift chamber gap, achieving sampling intervals roughly 10 times smaller than any previous study. A single layer drift chamber was used, and tracks of 1 meter length were simulated by combining together samples from many identified particles in this detector. These data were used to study the resolving power for particle identification as a function of sample size, averaging technique, and the number of discrimination levels (ADC bits) used for pulse height measurements

  2. Comparing the effects of rise time and inspiratory cycling criteria on 6 different mechanical ventilators.

    Science.gov (United States)

    Gonzales, Joshua F; Russian, Christopher J; Gregg Marshall, S; Collins, Kevin P

    2013-03-01

    Inspiratory rise time and cycling criteria are important settings in pressure support ventilation. The purpose of this study was to investigate the impact of minimum and maximum rise time and inspiratory cycling criteria settings on 6 new generation ventilators. Our hypothesis was there would be a difference in the exhaled tidal volume, inspiratory time, and peak flow among 6 different ventilators, based, on change in rise time and cycling criteria. The research utilized a breathing simulator and 4 different ventilator models. All mechanical ventilators were set to a spontaneous mode of ventilation with settings of pressure support 8 cm H2O and PEEP of 5 cm H2O. A minimum and maximum setting for rise time and cycling criteria were examined. Exhaled tidal volume, inspiratory time, and peak flow measurements were recorded for each simulation. Significant (P ventilator. Significant differences in exhaled tidal volume, inspiratory time, and peak flow were observed by adjusting rise time and cycling criteria. This research demonstrates that during pressure support ventilation strategy, adjustments in rise time and/or cycling criteria can produce changes in inspiratory parameters. Obviously, this finding has important implications for practitioners who utilize a similar pressure support strategy when conducting a ventilator wean. Additionally, this study outlines major differences among ventilator manufacturers when considering inspiratory rise time and cycling criteria.

  3. Should a carbon tax rise or fall over time?

    International Nuclear Information System (INIS)

    Ulph, Alistair; Ulph, David; Pezzey, John

    1991-01-01

    A carbon tax has been proposed as one possible way of reducing the emissions of ''greenhouse gases''. Much of the recent work on carbon taxation has concentrated on analysing the effects of introducing such a tax at a level which would meet certain emission targets at some fixed date. Less attention has been devoted to the time profile of this tax. Yet in securing international agreement on the introduction of a carbon tax it could matter greatly whether what is being proposed is a tax which is initially low but rising, or initially high but falling. We show that in a wide class of cases the optimal time path of the tax will be that it initially rises and then falls as the exhaustion constraint starts to bite. However there are few general conclusions, and much depends on more detailed modelling assumptions on which the scientific evidence gives no firm guidance. (author)

  4. Neural processing of amplitude and formant rise time in dyslexia.

    Science.gov (United States)

    Peter, Varghese; Kalashnikova, Marina; Burnham, Denis

    2016-06-01

    This study aimed to investigate how children with dyslexia weight amplitude rise time (ART) and formant rise time (FRT) cues in phonetic discrimination. Passive mismatch responses (MMR) were recorded for a/ba/-/wa/contrast in a multiple deviant odd-ball paradigm to identify the neural response to cue weighting in 17 children with dyslexia and 17 age-matched control children. The deviant stimuli had either partial or full ART or FRT cues. The results showed that ART did not generate an MMR in either group, whereas both partial and full FRT cues generated MMR in control children while only full FRT cues generated MMR in children with dyslexia. These findings suggest that children, both controls and those with dyslexia, discriminate speech based on FRT cues and not ART cues. However, control children have greater sensitivity to FRT cues in speech compared to children with dyslexia. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. X-ray polarimetry with a conventional gas proportional counter through rise-time analysis

    CERN Document Server

    Hayashida, K; Tsunemi, H; Torii, K; Murakami, H; Ohno, Y; Tamura, K

    1999-01-01

    We have performed an experiment on the signal rise time of a Xe gas proportional counter using a polarized X-ray beam of synchrotron orbital radiation with energies from 10 to 40 keV. When the counter anode is perpendicular to the electric vector of the incident X-ray photons, the average rise time becomes significantly longer than that for the parallel case. This indicates that the conventional gas proportional counters are useful for X-ray polarimetry. The moderate modulation contrast of this rise-time polarimeter (M=0.1 for 10 keV X-rays and M=0.35 for 40 keV X-rays), with capability of the simultaneous measuring X-ray energies and the timing, would be useful for applications in X-ray astronomy and in other fields.

  6. Development of a fast rise-time, high-voltage pulse generator

    International Nuclear Information System (INIS)

    Zhang Yanxia; Zhu Jie; Li Xianyou

    2006-01-01

    In order to test the attenuation of the system, a fast rise-time, high-voltage pulse generator is required for the fast pulse signal measurement. The paper presents the development of the generator. More emphasis is paid on the discussion of the difficulties occurring in the circuit debugging and their resolutions. The output rise-time of the generator is 700 ps, the amplitude is adjustable in the range of 0 to 500 V, the pulse-width is adjustable in the range of 4ns to 1μs. (authors)

  7. Amplitude and rise time compensated timing optimized for large semiconductor detectors

    International Nuclear Information System (INIS)

    Kozyczkowski, J.J.; Bialkowski, J.

    1976-01-01

    The ARC timing described has excellent timing properties even when using a wide range e.g. from 10 keV to over 1 MeV. The detector signal from a preamplifier is accepted directly by the unit as a timing filter amplifier with a sensitivity of 1 mV is incorporated. The adjustable rise time rejection feature makes it possible to achieve a good prompt time spectrum with symmetrical exponential shape down to less than 1/100 of the peak value. A complete block diagram of the unit is given together with results of extensive tests of its performance. For example the time spectrum for (1330+-20) keV of 60 Co taken with a 43 cm 3 Ge(Li) detector has the following parameters: fwhm = 2.2ns, fwtm = 4.4 ns and fw (0.01) m = 7.6 ns and for (50 +- 10) keV of 22 Na the following was obtained: fwhm = 10.8 ns, fwtm = 21.6 ns and fw (0.01) m = 34.6 ns. In another experiment with two fast plastic scintillations (NE 102A) and using a 20% dynamic energy range the following was measured: fwhm = 280 ps, fwtm = 470 ps and fw (0.01) m = 70ps. (Auth.)

  8. Fast rise time IR detectors for lepton colliders

    International Nuclear Information System (INIS)

    Drago, A.; Bini, S.; Guidi, M. Cestelli; Marcelli, A.; Pace, E.

    2016-01-01

    Diagnostics is a fundamental issue for accelerators whose demands are continuously increasing. In particular bunch-by-bunch diagnostics is a key challenge for the latest generation of lepton colliders and storage rings. The Frascati Φ-factory, DAΦNE, colliding at 1.02 GeV in the centre of mass, hosts in the main rings few synchrotron radiation beamlines and two of them collect the synchrotron radiation infrared emission: SINBAD from the electron ring and 3+L from the positron ring. At DAΦNE each bucket is 2.7 ns long and particles are gathered in bunches emitting pulsed IR radiation, whose intensity in the long wavelength regime is directly proportional to the accumulated particles. Compact uncooled photoconductive HgCdTe detectors have been tested in both beamlines using dedicated optical layouts. Actually, the fast rise time of HgCdTe semiconductors give us the chance to test bunch-by-bunch devices for both longitudinal and transverse diagnostics. For the longitudinal case, single pixel detectors have been used, while for the transverse diagnostics, multi-pixel array detectors, with special custom design, are under test. This contribution will briefly describe the status of the research on fast IR detectors at DAΦNE, the results obtained and possible foreseen developments.

  9. SPS Injection and Beam Quality for LHC Heavy Ions With 150 ns Kicker Rise Time

    CERN Document Server

    Goddard, Brennan; Ducimetière, Laurent; Kotzian, Gerd; Uythoven, Jan; Velotti, Francesco

    2016-01-01

    As part of the LHC Injectors Upgrade project for LHC heavy ions, the SPS injection kicker system rise time needs reduction below its present 225 ns. One technically challenging option under consideration is the addition of fast Pulse Forming Lines in parallel to the existing Pulse Forming Networks for the 12 kicker magnets MKP-S, targeting a system field rise time of 100 ns. An alternative option is to optimise the system to approach the existing individual magnet field rise time (2-98%) of 150 ns. This would still significantly increase the number of colliding bunches in LHC while minimising the cost and effort of the system upgrade. The observed characteristics of the present system are described, compared to the expected system rise time, together with results of simulations and measurements with 175 and 150 ns injection batch spacing. The expected beam quality at injection into LHC is quantified, with the emittance growth and simulated tail population taking into account expected jitter and synchronisatio...

  10. Time Impact of Scheduling Simulation for High Rise Building

    OpenAIRE

    Asmadi Ismail; Mohamad Ibrahim Mohamad; Muhamad Azani Yahya

    2011-01-01

    Although the long-introduced Industrialised Building System (IBS) has promised to solve and improve the current construction method and scenario in our country, but the IBS method has not gained enough popularity. One of the reasons is due to lack of research works done to quantifying the benefit of IBS especially in construction time saving. In lieu with such scenario, this study conducted to quantify evidence of time saving in IBS application. The methodology adopted for this study is by mo...

  11. Generation of fast-rise time, repetitive, (sub) nanosecond, high-voltage pulses

    NARCIS (Netherlands)

    Huiskamp, T.; Pemen, A.J.M.

    2017-01-01

    In this contribution we present our fast-rise time nanosecond pulse generator, capable of generating up to 50 kV (positive and negative) rectangular pulses at a repetition rate of up to 1 kHz and with a rise time of less than 200 picoseconds. We focus on the general concepts involved in the design

  12. Effect of rising time of rectangular pulse on inactivation of staphylococcus aureus by pulsed electric field

    Science.gov (United States)

    Zhang, Ruobing; Liang, Dapeng; Zheng, Nanchen; Xiao, Jianfu; Mo, Mengbin; Li, Jing

    2013-03-01

    Pulsed electric field (PEF) is a novel non-thermal food processing technology that involves the electric discharge of high voltage short pulses through the food product. In PEF study, rectangular pulses are most commonly used for inactivating microorganisms. However, little information is available on the inactivation effect of rising time of rectangular pulse. In this paper, inactivation effects, electric field strength, treatment time and conductivity on staphylococcus aureus inactivation were investigated when the pulse rising time is reduced from 2.5 μs to 200 ns. Experimental results showed that inactivation effect of PEF increased with electric field strength, solution conductivity and treatment time. Rising time of the rectangular pulse had a significant effect on the inactivation of staphylococcus aureus. Rectangular pulses with a rising time of 200 ns had a better inactivation effect than that with 2 μs. In addition, temperature increase of the solution treated by pulses with 200 ns rising time was lower than that with 2 μs. In order to obtain a given inactivation effect, treatment time required for the rectangular pulse with 200 ns rise time was shorter than that with 2 μs.

  13. Effect of rising time of rectangular pulse on inactivation of staphylococcus aureus by pulsed electric field

    International Nuclear Information System (INIS)

    Zhang, Ruobing; Liang, Dapeng; Xiao, Jianfu; Mo, Mengbin; Li, Jing; Zheng, Nanchen

    2013-01-01

    Pulsed electric field (PEF) is a novel non-thermal food processing technology that involves the electric discharge of high voltage short pulses through the food product. In PEF study, rectangular pulses are most commonly used for inactivating microorganisms. However, little information is available on the inactivation effect of rising time of rectangular pulse. In this paper, inactivation effects, electric field strength, treatment time and conductivity on staphylococcus aureus inactivation were investigated when the pulse rising time is reduced from 2.5 μs to 200 ns. Experimental results showed that inactivation effect of PEF increased with electric field strength, solution conductivity and treatment time. Rising time of the rectangular pulse had a significant effect on the inactivation of staphylococcus aureus. Rectangular pulses with a rising time of 200 ns had a better inactivation effect than that with 2 μs. In addition, temperature increase of the solution treated by pulses with 200 ns rising time was lower than that with 2 μs. In order to obtain a given inactivation effect, treatment time required for the rectangular pulse with 200 ns rise time was shorter than that with 2 μs.

  14. Timed Rise from Floor as a Predictor of Disease Progression in Duchenne Muscular Dystrophy: An Observational Study.

    Directory of Open Access Journals (Sweden)

    Elena S Mazzone

    Full Text Available The role of timed items, and more specifically, of the time to rise from the floor, has been reported as an early prognostic factor for disease progression and loss of ambulation. The aim of our study was to investigate the possible effect of the time to rise from the floor test on the changes observed on the 6MWT over 12 months in a cohort of ambulant Duchenne boys.A total of 487 12-month data points were collected from 215 ambulant Duchenne boys. The age ranged between 5.0 and 20.0 years (mean 8.48 ±2.48 DS.The results of the time to rise from the floor at baseline ranged from 1.2 to 29.4 seconds in the boys who could perform the test. 49 patients were unable to perform the test at baseline and 87 at 12 month The 6MWT values ranged from 82 to 567 meters at baseline. 3 patients lost the ability to perform the 6mwt at 12 months. The correlation between time to rise from the floor and 6MWT at baseline was high (r = 0.6, p<0.01.Both time to rise from the floor and baseline 6MWT were relevant for predicting 6MWT changes in the group above the age of 7 years, with no interaction between the two measures, as the impact of time to rise from the floor on 6MWT change was similar in the patients below and above 350 m. Our results suggest that, time to rise from the floor can be considered an additional important prognostic factor of 12 month changes on the 6MWT and, more generally, of disease progression.

  15. Influence of voltage rise time on microwave generation in relativistic backward wave oscillator

    International Nuclear Information System (INIS)

    Wu, Ping; Deng, Yuqun; Sun, Jun; Teng, Yan; Shi, Yanchao; Chen, Changhua

    2015-01-01

    In relativistic backward wave oscillators (RBWOs), although the slow wave structure (SWS) and electron beam determine the main characteristics of beam-wave interaction, many other factors can also significantly affect the microwave generation process. This paper investigates the influence of voltage rise time on beam-wave interaction in RBWOs. Preliminary analysis and PIC simulations demonstrate if the voltage rise time is moderately long, the microwave frequency will gradually increase during the startup process until the voltage reaches its amplitude, which can be explained by the dispersion relation. However, if the voltage rise time is long enough, the longitudinal resonance of the finitely-long SWS will force the RBWO to work with unwanted longitudinal modes for a while and then gradually hop to the wanted longitudinal mode, and this will lead to an impure microwave frequency spectrum. Besides, a longer voltage rise time will delay the startup process and thus lead to a longer microwave saturation time. And if unwanted longitudinal modes are excited due to long voltage rise time, the microwave saturation time will be further lengthened. Therefore, the voltage rise time of accelerators adopted in high power microwave technology should not be too long in case unwanted longitudinal modes are excited

  16. Influence of the Gilbert damping constant on the flux rise time of write head fields

    International Nuclear Information System (INIS)

    Ertl, Othmar; Schrefl, Thomas; Suess, Dieter; Schabes, Manfred E.

    2005-01-01

    Magnetic recording at fast data rates requires write heads with rapid rise times of the magnetic flux during the write process. We present three-dimensional (3D) micromagnetic finite element calculations of an entire ring head including 3D coil geometry during the writing of magnetic bits in granular media. The simulations demonstrate how input current profiles translate into magnetization processes in the head and which in turn generate the write head field. The flux rise time significantly depends on the Gilbert damping constant of the head material. Low damping causes incoherent magnetization processes, leading to long rise times and low head fields. High damping leads to coherent reversal of the magnetization in the head. As a consequence, the gap region can be quickly saturated which causes high head fields with short rise times

  17. Uniqueness in time measurement

    International Nuclear Information System (INIS)

    Lorenzen, P.

    1981-01-01

    According to P. Janich a clock is defined as an apparatus in which a point ( hand ) is moving uniformly on a straight line ( path ). For the definition of uniformly first the scaling (as a constant ratio of velocities) is defined without clocks. Thereafter the uniqueness of the time measurement can be proved using the prove of scaling of all clocks. But the uniqueness can be defined without scaling, as it is pointed out here. (orig.) [de

  18. Comparison of vacuum rise time, vacuum limit accuracy, and occlusion break surge of 3 new phacoemulsification systems.

    Science.gov (United States)

    Han, Young Keun; Miller, Kevin M

    2009-08-01

    To compare vacuum rise time, vacuum limit accuracy, and occlusion break surge of 3 new phacoemulsification machines. Jules Stein Eye Institute and Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, California, USA. The vacuum rise time under normal and enhanced aspiration modes, vacuum limit accuracy, and occlusion break surge of the Infiniti Vision System, Stellaris Vision Enhancement System, and WhiteStar Signature Phacoemulsification System were tested. Vacuum rise time and limit accuracy were measured at limit settings of 400 mm Hg and 600 mm Hg. Surge area was recorded at vacuum limit settings of 200 mm Hg, 300 mm Hg, 400 mm Hg, and 500 mm Hg. The Infiniti had the fastest vacuum rise times under normal and enhanced aspiration modes. At 4 seconds, the vacuum limit accuracy was greatest with the Infiniti at the 400 mm Hg limit and the Signature at the 600 mm Hg limit. The Stellaris did not reach either vacuum target. The Infiniti performed better than the other 2 machines during testing of occlusion break surge at all vacuum limit settings above 200 mm Hg. Under controlled laboratory test conditions, the Infiniti had the fastest vacuum rise time, greatest vacuum limit accuracy at 400 mm Hg, and least occlusion break surge. These results can be explained by the lower compliance of the Infiniti system.

  19. Measuring functional limitations in rising and sitting down: Development of a questionnaire

    NARCIS (Netherlands)

    Roorda, L.D.; Roebroeck, M.E.; Lankhorst, G.J.; van Tilburg, T.G.; Bouter, L.M.

    1996-01-01

    Objective: Develop and test a self-administered questionnaire that measures perceived and actual functional limitations in rising and sitting down. Setting: Private practices for physical therapy and outpatient clinics of hospitals and rehabilitation centers. Patients: 345 outpatients (43% male,

  20. Correction of incomplete charge collection in CdTe detectors using the correlation with the rise time distribution

    International Nuclear Information System (INIS)

    Horovitz, Yossi.

    1994-01-01

    Experimentally and theoretically it was found that there is a correlation between tile pulse rise time and the amount of charge that is collected in the detector contacts. As the rise time becomes longer less charge is collected. In this thesis it has been proven that one can find from this correlation, with the aid of a mathematical function, the theoretical amount of charge that has to be collected in the contacts if no trapping took place. This mathematical function called the correction function, f(t), is dependent on the rise time and the material quality (the trap concentration). In order to find the correction function, a computer, simulation was written. This computer program simulates, based on a phenomenological theoretical model, the charge collection in the detector. This model depends on three parameters (for the holes and for the electrons) that characterized the charge collection quality of the detector. The parameters are: the mean free time to be trapped, the detrapping time and the transit time that depends on the electric field. By a comparison between the simulation output and experimental data, these parameters were found. The correction function was found to be linear with rise time. This conclusion is confirmed experimentally. In this work experiments have been carried out that measured the correlation between two parameters. These experiments measured, for each photon that interacts with the detector, the pulse rise time and the pulse amplitude. A computer program accepts these spectra and substitute each element in the correction function and corrects for the incomplete charge collection. It was found that the correction function does not depend on the energy of the radiation source and source-detector geometry but depends on the material quality. The application of the correction function to the two dimensional spectra gives a correction of tens of percents in charge collection and provides an improvement in the resolution and the peak

  1. Comparison of occlusion break responses and vacuum rise times of phacoemulsification systems.

    Science.gov (United States)

    Sharif-Kashani, Pooria; Fanney, Douglas; Injev, Val

    2014-07-30

    Occlusion break surge during phacoemulsification cataract surgery can lead to potential surgical complications. The purpose of this study was to quantify occlusion break surge and vacuum rise time of current phacoemulsification systems used in cataract surgery. Occlusion break surge at vacuum pressures between 200 and 600 mmHg was assessed with the Infiniti® Vision System, the WhiteStar Signature® Phacoemulsification System, and the Centurion® Vision System using gravity-fed fluidics. Centurion Active FluidicsTM were also tested at multiple intraoperative pressure target settings. Vacuum rise time was evaluated for Infiniti, WhiteStar Signature, Centurion, and Stellaris® Vision Enhancement systems. Rise time to vacuum limits of 400 and 600 mmHg was assessed at flow rates of 30 and 60 cc/minute. Occlusion break surge was analyzed by 2-way analysis of variance. The Centurion system exhibited substantially less occlusion break surge than the other systems tested. Surge area with Centurion Active Fluidics was similar to gravity fluidics at an equivalent bottle height. At all Centurion Active Fluidics intraoperative pressure target settings tested, surge was smaller than with Infiniti and WhiteStar Signature. Infiniti had the fastest vacuum rise time and Stellaris had the slowest. No system tested reached the 600-mmHg vacuum limit. In this laboratory study, Centurion had the least occlusion break surge and similar vacuum rise times compared with the other systems tested. Reducing occlusion break surge may increase safety of phacoemulsification cataract surgery.

  2. A microchannel plate X-ray multiplier with rising-time less than 170 ps

    International Nuclear Information System (INIS)

    Zhao Shicheng; Ouyang Bin

    1987-01-01

    The time reponse of a microchannel plate X-ray multiplier has been improved considerably by using a coupling construction of coaxial tapers. The experimental calibration results with laser plasma X-ray source show that the rising-time of the multiplier is less than 170 ps

  3. Discriminating cosmic muons and X-rays based on rise time using a GEM detector

    Science.gov (United States)

    Wu, Hui-Yin; Zhao, Sheng-Ying; Wang, Xiao-Dong; Zhang, Xian-Ming; Qi, Hui-Rong; Zhang, Wei; Wu, Ke-Yan; Hu, Bi-Tao; Zhang, Yi

    2016-08-01

    Gas electron multiplier (GEM) detectors have been used in cosmic muon scattering tomography and neutron imaging over the last decade. In this work, a triple GEM device with an effective readout area of 10 cm × 10 cm is developed, and a method of discriminating between cosmic muons and X-rays based on rise time is tested. The energy resolution of the GEM detector is tested by 55Fe ray source to prove the GEM detector has a good performance. Analysis of the complete signal-cycles allows us to get the rise time and pulse heights. The experiment result indicates that cosmic muons and X-rays can be discriminated with an appropriate rise time threshold. Supported by National Natural Science Foundation of China (11135002, 11275235, 11405077, 11575073)

  4. Complex Contact Angles Calculated from Capillary Rise Measurements on Rock Fracture Faces

    Science.gov (United States)

    Perfect, E.; Gates, C. H.; Brabazon, J. W.; Santodonato, L. J.; Dhiman, I.; Bilheux, H.; Bilheux, J. C.; Lokitz, B. S.

    2017-12-01

    Contact angles for fluids in unconventional reservoir rocks are needed for modeling hydraulic fracturing leakoff and subsequent oil and gas extraction. Contact angle measurements for wetting fluids on rocks are normally performed using polished flat surfaces. However, such prepared surfaces are not representative of natural rock fracture faces, which have been shown to be rough over multiple scales. We applied a variant of the Wilhelmy plate method for determining contact angle from the height of capillary rise on a vertical surface to the wetting of rock fracture faces by water in the presence of air. Cylindrical core samples (5.05 cm long x 2.54 cm diameter) of Mancos shale and 6 other rock types were investigated. Mode I fractures were created within the cores using the Brazilian method. Each fractured core was then separated into halves exposing the fracture faces. One fracture face from each rock type was oriented parallel to a collimated neutron beam in the CG-1D imaging instrument at ORNL's High Flux Isotope Reactor. Neutron radiography was performed using the multi-channel plate detector with a spatial resolution of 50 μm. Images were acquired every 60 s after a water reservoir contacted the base of the fracture face. The images were normalized to the initial dry condition so that the upward movement of water on the fracture face was clearly visible. The height of wetting at equilibrium was measured on the normalized images using ImageJ. Contact angles were also measured on polished flat surfaces using the conventional sessile drop method. Equilibrium capillary rise on the exposed fracture faces was up to 8.5 times greater than that predicted for polished flat surfaces from the sessile drop measurements. These results indicate that rock fracture faces are hyperhydrophilic (i.e., the height of capillary rise is greater than that predicted for a contact angle of zero degrees). The use of complex numbers permitted calculation of imaginary contact angles for

  5. Modular High Voltage Pulse Converter for Short Rise and Decay Times

    NARCIS (Netherlands)

    Mao, S.

    2018-01-01

    This thesis explores a modular HV pulse converter technology with short rise and decay times. A systematic methodology to derive and classify HV architectures based on a modularization level of power building blocks of the HV pulse converter is developed to summarize existing architectures and

  6. Measuring Business Cycle Time.

    OpenAIRE

    Stock, James H

    1987-01-01

    The business cycle analysis of Arthur F. Burns and Wesley C. Mitchell and the National Bureau of Economic Research presumed that aggregate economic variables evolve on a time scale defined by business cycle turning points rather than by months or quarters. Do macroeconomic variables appear to evolve on an economic rather than a calendar time scale? Evidence presented here suggests that they do. However, the estimated economic time scales are only weakly related to business cycle time scales, ...

  7. Probing the neutrino mass hierarchy with the rise time of a supernova burst

    Science.gov (United States)

    Serpico, Pasquale D.; Chakraborty, Sovan; Fischer, Tobias; Hüdepohl, Lorenz; Janka, Hans-Thomas; Mirizzi, Alessandro

    2012-04-01

    The rise time of a Galactic supernova (SN) ν¯e light curve, observable at a high-statistics experiment such as the Icecube Cherenkov detector, can provide a diagnostic tool for the neutrino mass hierarchy at “large” 1-3 leptonic mixing angle ϑ13. Thanks to the combination of matter suppression of collective effects at early post-bounce times on one hand and the presence of the ordinary Mikheyev-Smirnov-Wolfenstein effect in the outer layers of the SN on the other hand, a sufficiently fast rise time on O(100)ms scale is indicative of an inverted mass hierarchy. We investigate results from an extensive set of stellar core-collapse simulations, providing a first exploration of the astrophysical robustness of these features. We find that for all the models analyzed (sharing the same weak interaction microphysics) the rise times for the same hierarchy are similar not only qualitatively, but also quantitatively, with the signals for the two classes of hierarchies significantly separated. We show via Monte Carlo simulations that the two cases should be distinguishable at IceCube for SNe at a typical Galactic distance 99% of the time. Finally, a preliminary survey seems to show that the faster rise time for inverted hierarchy as compared to normal hierarchy is a qualitatively robust feature predicted by several simulation groups. Since the viability of this signature ultimately depends on the quantitative assessment of theoretical/numerical uncertainties, our results motivate an extensive campaign of comparison of different code predictions at early accretion times with implementation of microphysics of comparable sophistication, including effects such as nucleon recoils in weak interactions.

  8. Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement

    International Nuclear Information System (INIS)

    TROYER, G.L.

    2000-01-01

    High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to characterize the pulse rise time of deposited gamma photons. Time discrimination was used to characterize the pulse rise time versus photo peak position and resolution. These data were collected to investigate the effect of pulse rise time compensation on resolution and efficiency

  9. Rise time of voltage pulses in NbN superconducting single photon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Smirnov, K. V. [Moscow State Pedagogical University, 1 Malaya Pirogovskaya St., 119435 Moscow (Russian Federation); CJSC “Superconducting Nanotechnology” (Scontel), 5/22-1 Rossolimo St., 119021 Moscow (Russian Federation); National Research University Higher School of Economics, Moscow Institute of Electronics and Mathematics, 34 Tallinskaya St., 109028 Moscow (Russian Federation); Divochiy, A. V.; Karpova, U. V.; Morozov, P. V. [CJSC “Superconducting Nanotechnology” (Scontel), 5/22-1 Rossolimo St., 119021 Moscow (Russian Federation); Vakhtomin, Yu. B.; Seleznev, V. A. [Moscow State Pedagogical University, 1 Malaya Pirogovskaya St., 119435 Moscow (Russian Federation); CJSC “Superconducting Nanotechnology” (Scontel), 5/22-1 Rossolimo St., 119021 Moscow (Russian Federation); Sidorova, M. V. [Moscow State Pedagogical University, 1 Malaya Pirogovskaya St., 119435 Moscow (Russian Federation); Zotova, A. N.; Vodolazov, D. Yu. [Institute for Physics of Microstructure, Russian Academy of Sciences, GSP-105, 603950 Nizhny Novgorod (Russian Federation); Lobachevsky State University of Nizhny Novgorod, 23 Gagarin Avenue, 603950 Nizhny Novgorod (Russian Federation)

    2016-08-01

    We have found experimentally that the rise time of voltage pulse in NbN superconducting single photon detectors increases nonlinearly with increasing the length of the detector L. The effect is connected with dependence of resistance of the detector R{sub n}, which appears after photon absorption, on its kinetic inductance L{sub k} and, hence, on the length of the detector. This conclusion is confirmed by our calculations in the framework of two temperature model.

  10. Effect of rise-time patterns on dynamics of sheath expansion during plasma immersion ion implantation

    International Nuclear Information System (INIS)

    Huang Yongxian; Tian Xiubo; Yang Shiqin; Fu Ricky; Paul, C.K.

    2007-01-01

    Plasma immersion ion implantation (PIII) has been developed as a low-cost and efficient surface modification technique of irregularly-shaped objects. The effect of six pulse waves with different rise-time patterns on the spatio-temporal evolution of plasma sheath,energy and dose of ion implantation has been simulated by particle-in-cell modeling. Statistical results may be obtained through assuming the Boltzmann distribution of electrons, and solving Poisson and Newton equations for tracing each ion in the plasma sheath. The results show that rise-time pattern has a critical influence on the evolution of plasma sheath. There exists maximum thickness difference of plasma sheath for different waveforms. The acceleration of ions is non-uniform due to the non-uniformity of electrical field strength. The maximum gradient of electrical field appears near the edge of plasma sheath. The results also show that optimization of dose and energy of incident ions may be achieved through modification of rise-time pattern. The numerical simulation of sheath expansion can be effectively used to provide a scientific basis for optimizing the PIII process. (authors)

  11. Sea-level rise and shoreline retreat: time to abandon the Bruun Rule

    Science.gov (United States)

    Cooper, J. Andrew G.; Pilkey, Orrin H.

    2004-11-01

    In the face of a global rise in sea level, understanding the response of the shoreline to changes in sea level is a critical scientific goal to inform policy makers and managers. A body of scientific information exists that illustrates both the complexity of the linkages between sea-level rise and shoreline response, and the comparative lack of understanding of these linkages. In spite of the lack of understanding, many appraisals have been undertaken that employ a concept known as the "Bruun Rule". This is a simple two-dimensional model of shoreline response to rising sea level. The model has seen near global application since its original formulation in 1954. The concept provided an advance in understanding of the coastal system at the time of its first publication. It has, however, been superseded by numerous subsequent findings and is now invalid. Several assumptions behind the Bruun Rule are known to be false and nowhere has the Bruun Rule been adequately proven; on the contrary several studies disprove it in the field. No universally applicable model of shoreline retreat under sea-level rise has yet been developed. Despite this, the Bruun Rule is in widespread contemporary use at a global scale both as a management tool and as a scientific concept. The persistence of this concept beyond its original assumption base is attributed to the following factors: Appeal of a simple, easy to use analytical model that is in widespread use. Difficulty of determining the relative validity of 'proofs' and 'disproofs'. Ease of application. Positive advocacy by some scientists. Application by other scientists without critical appraisal. The simple numerical expression of the model. Lack of easy alternatives. The Bruun Rule has no power for predicting shoreline behaviour under rising sea level and should be abandoned. It is a concept whose time has passed. The belief by policy makers that it offers a prediction of future shoreline position may well have stifled much

  12. SN 2008iy: An Unusual Type IIn Supernova with an Enduring 400 Day Rise Time

    OpenAIRE

    Miller, A. A.; Silverman, J. M.; Butler, N. R.; Bloom, J. S.; Chornock, R.; Filippenko, A. V.; Ganeshalingam, M.; Klein, C. R.; Li, W.; Nugent, P. E.; Smith, N.; Steele, T. N.

    2009-01-01

    We present spectroscopic and photometric observations of the Type IIn supernova (SN) 2008iy. SN 2008iy showed an unprecedentedly long rise time of ~400 days, making it the first SN to take significantly longer than 100 days to reach peak optical luminosity. The peak absolute magnitude of SN 2008iy was M_r ~ -19.1 mag, and the total radiated energy over the first ~700 days was ~2 x 10^50 erg. Spectroscopically, SN 2008iy is very similar to the Type IIn SN 1988Z at late times, and, like SN 1988...

  13. Ground potential rise on the high voltage substation during lightning strike measurement and simulation results

    Energy Technology Data Exchange (ETDEWEB)

    Wiater, Jaroslaw [Bialystok Technical University (Poland). Electrical Dept.], E-mail: jaroslawwiater@we.pb.edu.pl

    2007-07-01

    This paper will present a ground potential rise (GPR) measurement results. All measurements were made during normal work of the real high voltage substation and according a special procedure developed for this occasion. This procedure does not influence on the protection relays and ensures a proper work of the substation even for 6 kV surges. During measurements current and voltage surges were produced by the impulse generator - UCS 500M6B. Measurement results are compared to simulation results performed in CDEGS software for the same initial conditions. (author)

  14. Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement

    CERN Document Server

    Troyer, G L

    2000-01-01

    High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to characterize the pulse rise time of deposited gamma photons. Time discrimination was used to characterize the pulse r...

  15. Analysis and Compensation of Dead-Time Effect of a ZVT PWM Inverter Considering the Rise- and Fall-Times

    Directory of Open Access Journals (Sweden)

    Hailin Zhang

    2016-11-01

    Full Text Available The dead-time effect, as an intrinsic problem of the converters based on the half-bridge unit, leads to distortions in the converter output. Although several dead-time effect compensation or elimination methods have been proposed, they cannot fully remove the dead-time effect of blanking delay error, because the output current polarity is difficult detect accurately. This paper utilizes the zero-voltage-switching (ZVT technique to eliminate the blanking delay error, which is the main drawback of the hard-switching inverter, although the technique initially aims to improve the efficiency. A typical ZVT inverter—the auxiliary resonant snubber inverter (ARSI is analyzed. The blanking delay error is completely eliminated in the ARSI. Another error source caused by the finite rise- and fall-times of the voltage is analyzed, which was not considered in the hard-switching inverter. A compensation method based on the voltage error estimation is proposed to compensate the rise- and fall-error. A prototype was developed to verify the effectiveness of the proposed control. Both the simulation and experimental results demonstrate that the qualities of the output current and voltage in the ARSI are better than that in the hard-switching inverter due to the elimination of the blanking delay error. The total harmonic distortion (THD of the output is further reduced by using the proposed compensation method in the ARSI.

  16. Rise time of proton cut-off energy in 2D and 3D PIC simulations

    Science.gov (United States)

    Babaei, J.; Gizzi, L. A.; Londrillo, P.; Mirzanejad, S.; Rovelli, T.; Sinigardi, S.; Turchetti, G.

    2017-04-01

    The Target Normal Sheath Acceleration regime for proton acceleration by laser pulses is experimentally consolidated and fairly well understood. However, uncertainties remain in the analysis of particle-in-cell simulation results. The energy spectrum is exponential with a cut-off, but the maximum energy depends on the simulation time, following different laws in two and three dimensional (2D, 3D) PIC simulations so that the determination of an asymptotic value has some arbitrariness. We propose two empirical laws for the rise time of the cut-off energy in 2D and 3D PIC simulations, suggested by a model in which the proton acceleration is due to a surface charge distribution on the target rear side. The kinetic energy of the protons that we obtain follows two distinct laws, which appear to be nicely satisfied by PIC simulations, for a model target given by a uniform foil plus a contaminant layer that is hydrogen-rich. The laws depend on two parameters: the scaling time, at which the energy starts to rise, and the asymptotic cut-off energy. The values of the cut-off energy, obtained by fitting 2D and 3D simulations for the same target and laser pulse configuration, are comparable. This suggests that parametric scans can be performed with 2D simulations since 3D ones are computationally very expensive, delegating their role only to a correspondence check. In this paper, the simulations are carried out with the PIC code ALaDyn by changing the target thickness L and the incidence angle α, with a fixed a0 = 3. A monotonic dependence, on L for normal incidence and on α for fixed L, is found, as in the experimental results for high temporal contrast pulses.

  17. 'Stutter timing' for charge decay time measurement

    Energy Technology Data Exchange (ETDEWEB)

    Chubb, John [Infostatic, 2 Monica Drive, Pittville, Cheltenham, GL50 4NQ (United Kingdom); Harbour, John [Hawthorne Technical Design, The Hawthornes, Startley, Chippenham, SN15 5HG,UK (United Kingdom); Pavey, Ian, E-mail: jchubb@infostatic.co.uk [Chilworth Technology Ltd, Beta House, Southampton Science Park, Southampton, SO16 7NS (United Kingdom)

    2011-06-23

    The paper describes the approach of 'stutter timing' that has been developed to improve the accuracy of measuring charge decay times in the presence of noise in compact and portable charge decay test instrumentation. The approach involves starting and stopping the timing clock as the noisy signal rises above and falls below the target threshold voltage level.

  18. Time dependent rise and decay of photocurrent in zinc oxide nanoparticles in ambient and vacuum medium

    Science.gov (United States)

    C, Rajkumar; Srivastava, Rajneesh K.

    2018-05-01

    Zinc oxide (ZnO) nanoparticle has been synthesized by cost effective Co-precipitation method and studied its photo-response activity. The synthesized ZnO nanomaterial was characterized by using various analytical techniques such as x-ray diffraction (XRD), UV–visible spectroscopy, FTIR spectroscopy, photoluminescence (PL) spectroscopy, and Scanning Electron Microscopy (SEM). From the XRD results, it is confirmed that synthesized ZnO nanomaterial possess hexagonal wurtzite phase structure with an average crystallite size of ∼16–17 nm. The UV-Visible absorption spectrum shows that it has blue shift compared to their bulk counterparts. Photoluminescence spectra of ZnO nanoparticles have a strong violet band at 423 nm and three weak bands at 485 nm (blue), 506 nm (green), and 529 nm (green). The presence of hydroxyl group was confirmed by FTIR. The photo-response analysis was studied by the time-dependent rise and decay photocurrent of ZnO nanoparticle was tested in the air as well as vacuum medium.

  19. Drift-time measurement electronics

    International Nuclear Information System (INIS)

    Pernicka, M.

    1978-01-01

    The aim of the construction was to improve the time resolution without using the facility of time stretching, to have a fast read-out possibility, and to be still cheaper in price in comparison to other systems. A possibility was thus foreseen for using the firm Fairchild. These integrated circuits (IC) have, for example, a propagation delay of 0.75 ns for a gate. One can expect therefore less time jitter and less time difference between the different inputs. Furthermore this IC offers a greater flexibility and therefore the number of ICs decreases and distances become smaller. Working with clock frequencies up to 166.6 MHz is easily possible without running into timing problems. On the other hand, to make full use of the advantages of this IC, it was necessary to build the print as a multilayer. The only risk could be in the use of a completely new product. A further aim was to build for this system a second type of drift-time module with a short time range for measuring drift time and pulse length in rotated multiwire proportional chambers. A brief outline of the specifications of the different modules is given in table 1. (Auth.)

  20. High-voltage isolation transformer for sub-nanosecond rise time pulses constructed with annular parallel-strip transmission lines.

    Science.gov (United States)

    Homma, Akira

    2011-07-01

    A novel annular parallel-strip transmission line was devised to construct high-voltage high-speed pulse isolation transformers. The transmission lines can easily realize stable high-voltage operation and good impedance matching between primary and secondary circuits. The time constant for the step response of the transformer was calculated by introducing a simple low-frequency equivalent circuit model. Results show that the relation between the time constant and low-cut-off frequency of the transformer conforms to the theory of the general first-order linear time-invariant system. Results also show that the test transformer composed of the new transmission lines can transmit about 600 ps rise time pulses across the dc potential difference of more than 150 kV with insertion loss of -2.5 dB. The measured effective time constant of 12 ns agreed exactly with the theoretically predicted value. For practical applications involving the delivery of synchronized trigger signals to a dc high-voltage electron gun station, the transformer described in this paper exhibited advantages over methods using fiber optic cables for the signal transfer system. This transformer has no jitter or breakdown problems that invariably occur in active circuit components.

  1. Resilience of Infrastructure Systems to Sea-Level Rise in Coastal Areas: Impacts, Adaptation Measures, and Implementation Challenges

    Directory of Open Access Journals (Sweden)

    Beatriz Azevedo de Almeida

    2016-11-01

    Full Text Available Expansive areas of low elevation in many densely populated coastal areas are at elevated risk of storm surges and flooding due to torrential precipitation, as a result of sea level rise. These phenomena could have catastrophic impacts on coastal communities and result in the destruction of critical infrastructure, disruption of economic activities and salt water contamination of the water supply. The objective of the study presented in this paper was to identify various impacts of sea level rise on civil infrastructures in coastal areas and examine the adaptation measures suggested in the existing literature. To this end, a systemic review of the existing literature was conducted in order to identify a repository of studies addressing sea level rise impacts and adaptation measures in the context of infrastructure systems. The study focused on three infrastructure sectors: water and wastewater, energy, and road transportation. The collected information was then analyzed in order to identify different categories of sea level rise impacts and corresponding adaptation measures. The findings of the study are threefold: (1 the major categories of sea level rise impacts on different infrastructure systems; (2 measures for protection, accommodation, and retreat in response to sea level rise impacts; and (3 challenges related to implementing adaptation measures.

  2. Time to PSA rise differentiates the PSA bounce after HDR and LDR brachytherapy of prostate cancer.

    Science.gov (United States)

    Burchardt, Wojciech; Skowronek, Janusz

    2018-02-01

    To investigate the differences in prostate-specific antigen (PSA) bounce (PB) after high-dose-rate (HDR-BT) or low-dose-rate (LDR-BT) brachytherapy alone in prostate cancer patients. Ninety-four patients with localized prostate cancer (T1-T2cN0), age ranged 50-81 years, were treated with brachytherapy alone between 2008 and 2010. Patients were diagnosed with adenocarcinoma, Gleason score ≤ 7. The LDR-BT total dose was 144-145 Gy, in HDR-BT - 3 fractions of 10.5 or 15 Gy. The initial PSA level (iPSA) was assessed before treatment, then PSA was rated every 3 months over the first 2 years, and every 6 months during the next 3 years. Median follow-up was 3.0 years. Mean iPSA was 7.8 ng/ml. In 58 cases, PSA decreased gradually without PB or biochemical failure (BF). In 24% of patients, PB was observed. In 23 cases (24%), PB was observed using 0.2 ng/ml definition; in 10 cases (11%), BF was diagnosed using nadir + 2 ng/ml definition. The HDR-BT and LDR-BT techniques were not associated with higher level of PB (26 vs. 22%, p = 0.497). Time to the first PSA rise finished with PB was significantly shorter after HDR-BT then after LDR-BT (median, 10.5 vs. 18.0 months) during follow-up. Predictors for PB were observed only after HDR-BT. Androgen deprivation therapy (ADT) and higher Gleason score decreased the risk of PB (HR = 0.11, p = 0.03; HR = 0.51, p = 0.01). The higher PSA nadir and longer time to PSA nadir increased the risk of PB (HR 3.46, p = 0.02; HR 1.04, p = 0.04). There was no predictors for PB after LDR-BT. HDR-BT and LDR-BT for low and intermediate risk prostate cancer had similar PB rate. The PB occurred earlier after HDR-BT than after LDR-BT. ADT and higher Gleason score decreased, and higher PSA nadir and longer time to PSA nadir increased the risk of PB after HDR-BT.

  3. Measuring health inequalities over time

    Directory of Open Access Journals (Sweden)

    Gustavo Bergonzoli

    2007-11-01

    Full Text Available Background: several methodologies have been used to measure health inequalities. Most of them do so in a cross- sectional fashion, causing significant loss of information. None of them measure health inequalities in social territories over time. Methods: this article presents two approaches measure health inequalities: one approach consists of a refinement of cross-sectional study, by using the analysis of ANOVA variance (ANOVA procedure to explore whether the gap between social territories is real or due to chance. Several adjustments were made to limit errors inevitably found in multiple comparisons. Polynomial procedures were then applied to identify and evaluate any trends. The second sociales se utilizó approach measures the health gap between social territories or strata (as defined in this study over time using the Poisson regression. These approaches were applied using life expectancy and maternal mortality data from Venezuela. Results: a positive relationship between tendenterritories and life expectancy was found, with a significant cia linal trend. The relation between maternal mortality and materna y territorios sociales fue cuadrática. La medición desocial territories was quadratic. The measurement of the la brecha, gap between least developed social territory and the most, a developed territory showed a gap reduction from the first to the second decade, mainly because of an increase of territorio social maternal mortality in the more developed area, rather than a real improvement in the least developed. Conclusions: study helps to clarify the impact that public policies and interventions have in reducing the health gap. Knowledge that a health gap between social territories can decrease without showing improvement in the least developed sector , is an important finding for monitoring and evaluating health interventions for improving living and health conditions in the population.

  4. Numerical Analysis on Temperature Rise of a Concrete Arch Dam after Sealing Based on Measured Data

    Directory of Open Access Journals (Sweden)

    Qingbin Li

    2014-01-01

    Full Text Available The thermal boundary conditions in the construction and operation phases of a concrete arch dam are always complex. After sealing, differences between the arch dam temperature and its sealing temperature can cause compressive or tensile stresses. Based on measured temperature of an arch dam located in China, a temperature rise phenomenon (TRP is found in the after-sealed regions of the arch dam. By mining and analyzing the temperature data of various monitoring apparatus embedded in the arch dam, higher environment temperature is considered to be the main cause for the occurrence of the TRP. Mathematical methods for complex thermal boundary conditions, including external boundary conditions and internal heat source conditions, are proposed in this paper. A finite element model is implemented with the concern of the construction phase and operation phase of the arch dam. Results confirm good agreement with the measured temperature and verify the conjecture that the TRP occurs mainly because the external temperature of the arch dam is higher than its sealing temperature.

  5. Gas Injection And Fast Pressure-Rise Measurements For The Linac4 H− Source

    CERN Document Server

    Mahner, E; Lettry, J; Mattei, S; O'Neil, M; Neupert, H; Pasquino, C; Schmitzer, C

    2013-01-01

    In the era of the Large Hadron Collider, the CERN injector complex comprising the 34 years old Linac2 with its primary proton source, is presently upgraded with a new linear accelerator for H− (Linac4). The design, construction, and test of volume production and cesiated RF-driven H− ion sources is presently ongoing with the final goal of producing an H− beam with 80 mA beam current, 45 keV beam energy, 500 s pulse length, and a repetition rate of 2 Hz. In order to have quantitative information of the hydrogen gas density at the moment of plasma ignition the dynamic vacuum properties of the plasma generator were studied experimentally. We describe the experimental setup and present fast pressure-rise measurements for different parameters of the gas injection system, such as gas species (H2, He, N2, Ar), piezo valve voltage pulse length (200 - 500 s), and injection pressure (400 - 2800 mbar). The obtained data are compared with a conductance model of the plasma generator.

  6. Spatial Hedonic Models for Measuring the Impact of Sea-Level Rise on Coastal Real Estate

    OpenAIRE

    Okmyung Bin; Ben Poulter; Christopher F. Dumas; John C. Whitehead

    2009-01-01

    This study uses a unique integration of geospatial and hedonic property data to estimate the impact of sea-level rise on coastal real estate in North Carolina. North Carolina’s coastal plain is one of several large terrestrial systems around the world threatened by rising sea-levels. High-resolution topographic LIDAR (Light Detection and Ranging) data are used to provide accurate inundation maps for all properties that will be at risk under six different sea-level rise scenarios. A simulation...

  7. Application of the pulse-rise-time discriminator for background noise decreasing in proportional x-ray counters

    International Nuclear Information System (INIS)

    Goganov, D.A.; Guslina, A.G.; Korolev, V.F.; Lozinskij, B.S.; Sklyankin, V.A.

    1977-01-01

    The intrinsic background of commercial rising edge discriminator - based proportional counters has been measured. The block-diagram of the experimental apparatus comprises the detector to be tested, a charge-sensitive amplifier with an amplitude analyzer, a rising edge discriminator (RED) and a scaling device. The rising edges have been analyzed in the range between 0.2 to 0.7 of the pulse amplitude. The RED threshold has been preset to cut off all the edges longer than those of 55 Fe (to register 87% of the 55 Fe quanta). It has been found that by limiting the amplitude discriminator window to +-20% and using a RED the background of commercial counters can be reduced by about an order

  8. Timing and mechanism of the rise of the Shillong Plateau in the Himalayan foreland.

    OpenAIRE

    Govin, Gwladys; Najman, Yanina Manya Rachel; Copley, Alex; Millar, Ian; Van der Beek, Peter; Huyghe, Pascale; Grujic, Djordje; Davenport, Jesse

    2018-01-01

    The Shillong Plateau (northeastern India) constitutes the only significant topography in the Himalayan foreland. Knowledge of its surface uplift history is key to understanding topographic development and unraveling tectonic–climate–topographic coupling in the eastern Himalaya. We use the sedimentary record of the Himalayan foreland basin north of the Shillong Plateau to show that the paleo-Brahmaputra river was redirected north and west by the rising plateau at 5.2–4.9 Ma. We suggest that on...

  9. 20 CFR 404.272 - Indexes we use to measure the rise in the cost-of-living.

    Science.gov (United States)

    2010-04-01

    ... cost-of-living. 404.272 Section 404.272 Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND DISABILITY INSURANCE (1950- ) Computing Primary Insurance Amounts Cost-Of-Living Increases § 404.272 Indexes we use to measure the rise in the cost-of-living. (a) The bases. To measure...

  10. Assessment of Temperature Rise and Time of Alveolar Ridge Splitting by Means of Er:YAG Laser, Piezosurgery, and Surgical Saw: An Ex Vivo Study.

    Science.gov (United States)

    Matys, Jacek; Flieger, Rafał; Dominiak, Marzena

    2016-01-01

    The most common adverse effect after bone cutting is a thermal damage. The aim of our study was to evaluate the bone temperature rise during an alveolar ridge splitting, rating the time needed to perform this procedure and the time to raise the temperature of a bone by 10°C, as well as to evaluate the bone carbonization occurrence. The research included 60 mandibles ( n = 60) of adult pigs, divided into 4 groups ( n = 15). Two vertical and one horizontal cut have been done in an alveolar ridge using Er:YAG laser with set power of 200 mJ (G1), 400 mJ (G2), piezosurgery unit (G3), and a saw (G4). The temperature was measured by K-type thermocouple. The highest temperature gradient was noted for piezosurgery on the buccal and lingual side of mandible. The temperature rises on the bone surface along with the increase of laser power. The lower time needed to perform ridge splitting was measured for a saw, piezosurgery, and Er:YAG laser with power of 400 mJ and 200 mJ, respectively. The temperature rise measured on the bone over 10°C and bone carbonization occurrence was not reported in all study groups. Piezosurgery, Er:YAG laser (200 mJ and 400 mJ), and surgical saw are useful and safe tools in ridge splitting surgery.

  11. Assessment of Temperature Rise and Time of Alveolar Ridge Splitting by Means of Er:YAG Laser, Piezosurgery, and Surgical Saw: An Ex Vivo Study

    Directory of Open Access Journals (Sweden)

    Jacek Matys

    2016-01-01

    Full Text Available The most common adverse effect after bone cutting is a thermal damage. The aim of our study was to evaluate the bone temperature rise during an alveolar ridge splitting, rating the time needed to perform this procedure and the time to raise the temperature of a bone by 10°C, as well as to evaluate the bone carbonization occurrence. The research included 60 mandibles (n=60 of adult pigs, divided into 4 groups (n=15. Two vertical and one horizontal cut have been done in an alveolar ridge using Er:YAG laser with set power of 200 mJ (G1, 400 mJ (G2, piezosurgery unit (G3, and a saw (G4. The temperature was measured by K-type thermocouple. The highest temperature gradient was noted for piezosurgery on the buccal and lingual side of mandible. The temperature rises on the bone surface along with the increase of laser power. The lower time needed to perform ridge splitting was measured for a saw, piezosurgery, and Er:YAG laser with power of 400 mJ and 200 mJ, respectively. The temperature rise measured on the bone over 10°C and bone carbonization occurrence was not reported in all study groups. Piezosurgery, Er:YAG laser (200 mJ and 400 mJ, and surgical saw are useful and safe tools in ridge splitting surgery.

  12. Measurement and evaluation of high-rise building response to ground motion generated by underground nuclear explosions

    International Nuclear Information System (INIS)

    Honda, K.K.

    1976-01-01

    As part of the structural response research program being conducted for ERDA, the response behavior of high-rise buildings in Las Vegas, Nevada, due to ground motion caused by underground nuclear explosions (UNEs) at the Nevada Test Site (NTS) has been measured for the past 12 years. Results obtained include variation in dynamic response properties as a function of amplitude of motion, influence of nonstructural partitions in the building response, and comparison of calculated and measured response. These data for three reinforced concrete high-rise buildings, all designed as moment-resisting space frames are presented

  13. Evaluation of Stiffness Changes in a High-Rise Building by Measurements of Lateral Displacements Using GPS Technology

    Science.gov (United States)

    Choi, Se Woon; Kim, Ill Soo; Park, Jae Hwan; Kim, Yousok; Sohn, Hong Gyoo; Park, Hyo Seon

    2013-01-01

    The outrigger truss system is one of the most frequently used lateral load resisting structural systems. However, little research has been reported on the effect of installation of outrigger trusses on improvement of lateral stiffness of a high-rise building through full-scale measurements. In this paper, stiffness changes of a high-rise building due to installation of outrigger trusses have been evaluated by measuring lateral displacements using a global positioning system (GPS). To confirm the error range of the GPS measurement system used in the full-scale measurement tests, the GPS displacement monitoring system is investigated through a free vibration test of the experimental model. Then, for the evaluation of lateral stiffness of a high-rise building under construction, the GPS displacement monitoring system is applied to measurements of lateral displacements of a 66-story high-rise building before and after installation of outrigger truss. The stiffness improvement of the building before and after the installation is confirmed through the changes of the natural frequencies and the ratios of the base shear forces to the roof displacements. PMID:24233025

  14. Evaluation of Stiffness Changes in a High-Rise Building by Measurements of Lateral Displacements Using GPS Technology

    Directory of Open Access Journals (Sweden)

    Se Woon Choi

    2013-11-01

    Full Text Available The outrigger truss system is one of the most frequently used lateral load resisting structural systems. However, little research has been reported on the effect of installation of outrigger trusses on improvement of lateral stiffness of a high-rise building through full-scale measurements. In this paper, stiffness changes of a high-rise building due to installation of outrigger trusses have been evaluated by measuring lateral displacements using a global positioning system (GPS. To confirm the error range of the GPS measurement system used in the full-scale measurement tests, the GPS displacement monitoring system is investigated through a free vibration test of the experimental model. Then, for the evaluation of lateral stiffness of a high-rise building under construction, the GPS displacement monitoring system is applied to measurements of lateral displacements of a 66-story high-rise building before and after installation of outrigger truss. The stiffness improvement of the building before and after the installation is confirmed through the changes of the natural frequencies and the ratios of the base shear forces to the roof displacements.

  15. Rise time reduction of thermal actuators operated in air and water through optimized pre-shaped open-loop driving

    International Nuclear Information System (INIS)

    Larsen, T; Doll, J C; Loizeau, F; Pruitt, B L; Hosseini, N; Fantner, G E; Peng, A W; Ricci, A J

    2017-01-01

    Electrothermal actuators have many advantages compared to other actuators used in micro-electro-mechanical systems (MEMS). They are simple to design, easy to fabricate and provide large displacements at low voltages. Low voltages enable less stringent passivation requirements for operation in liquid. Despite these advantages, thermal actuation is typically limited to a few kHz bandwidth when using step inputs due to its intrinsic thermal time constant. However, the use of pre-shaped input signals offers a route for reducing the rise time of these actuators by orders of magnitude. We started with an electrothermally actuated cantilever having an initial 10–90% rise time of 85 μ s in air and 234 μ s in water for a standard open-loop step input. We experimentally characterized the linearity and frequency response of the cantilever when operated in air and water, allowing us to obtain transfer functions for the two cases. We used these transfer functions, along with functions describing desired reduced rise-time system responses, to numerically simulate the required input signals. Using these pre-shaped input signals, we improved the open-loop 10–90% rise time from 85 μ s to 3 μ s in air and from 234 μ s to 5 μ s in water, an improvement by a factor of 28 and 47, respectively. Using this simple control strategy for MEMS electrothermal actuators makes them an attractive alternative to other high speed micromechanical actuators such as piezoelectric stacks or electrostatic comb structures which are more complex to design, fabricate, or operate. (paper)

  16. Rise Time Reduction of Thermal Actuators Operated in Air and Water through Optimized Pre-Shaped Open-Loop Driving.

    Science.gov (United States)

    Larsen, T; Doll, J C; Loizeau, F; Hosseini, N; Peng, A W; Fantner, G; Ricci, A J; Pruitt, B L

    2017-01-01

    Electrothermal actuators have many advantages compared to other actuators used in Micro-Electro-Mechanical Systems (MEMS). They are simple to design, easy to fabricate and provide large displacements at low voltages. Low voltages enable less stringent passivation requirements for operation in liquid. Despite these advantages, thermal actuation is typically limited to a few kHz bandwidth when using step inputs due to its intrinsic thermal time constant. However, the use of pre-shaped input signals offers a route for reducing the rise time of these actuators by orders of magnitude. We started with an electrothermally actuated cantilever having an initial 10-90% rise time of 85 μs in air and 234 μs in water for a standard open-loop step input. We experimentally characterized the linearity and frequency response of the cantilever when operated in air and water, allowing us to obtain transfer functions for the two cases. We used these transfer functions, along with functions describing desired reduced rise-time system responses, to numerically simulate the required input signals. Using these pre-shaped input signals, we improved the open-loop 10-90% rise time from 85 μs to 3 μs in air and from 234 μs to 5 μs in water, an improvement by a factor of 28 and 47, respectively. Using this simple control strategy for MEMS electrothermal actuators makes them an attractive alternative to other high speed micromechanical actuators such as piezoelectric stacks or electrostatic comb structures which are more complex to design, fabricate, or operate.

  17. Investigation on the Factors Influencing Construction Time and Cost Overrun for High-Rise Building Projects In Penang

    Science.gov (United States)

    Nor Haslinda, A.; Xian, T. Wei; Norfarahayu, K.; Muhamad Hanafi, R.; Fikri, H. Muhammad

    2018-04-01

    Time and cost overruns have become one prominent issue for most construction projects around the world. Project costing and timeframe extension had been causing a lot of wastage and loss of opportunity for many parties involved. Therefore, this research was carried out to investigate the factors influencing time and cost overruns for high-rise construction projects in Penang, Malaysia. A set of questionnaires survey was distributed to the project managers who had been or currently involved in the high-rise building projects in Penang to get their input and perceptions for each factor identified as well as its frequency of occurrence. In order to rank all the factors gathered, the mean index of the most distinguishing factors and its frequency of occurrence were multiplied to get the severity index. The results revealed that for time overrun, the most predominant causes were due to design changes, inadequate planning and scheduling and poor labor productivity. Meanwhile, the predominant causes of cost overrun were poor pre-construction budget and material cost planning, inaccurate quantity take-off and materials cost increased by inflation. The significance of establishing the issues related to time and cost overruns for the high-rise building construction project is to provide a greater insight and understanding on the causes of delays, particularly among the main project players: contractors, client, and consultants.

  18. The Rise of Euroscepticism in Times of Crisis. Evidence from the 2008–2013 Eurobarometers

    Directory of Open Access Journals (Sweden)

    Alina Bârgăoanu

    2016-05-01

    Full Text Available The financial and economic turmoil within the European Union has significantly impacted upon the way in which the European citizens assess the advantages of EU membership and the future of the integration process. Intensely preoccupied with the economic problems, the EU leadership has lost sight of the constant decrease of public support and the increasing lack of citizens’ confidence in the Union. This paper seeks to show the dynamics of public opinion between 2008 and 2013 with a special focus on the rise of Euroscepticism, using secondary data analysis of standard Eurobarometers. Our longitudinal analysis reveals the dynamics of EU-related attitudes and perceptions before, during, and after most of events that are usually labeled under the rather generic term “crisis”.

  19. Vulnerable areas and adapation measures for sea level rise along the coast of India

    Digital Repository Service at National Institute of Oceanography (India)

    Chauhan, O.S.; Unnikrishnan, A.S.; Menezes, A.A.A.; Jagtap, T.G.; Suneethi, J.; Furtado, R.

    India has a coastline of about 7500 km with contrasting geological setting. Based upon the available models, global sea level rise of 10-25 cm per 100 year has been predicted due to emission of green house gases. To separate out the influences due...

  20. Effects of drive current rise-time and initial load density distribution on Z-pinch characteristics

    Institute of Scientific and Technical Information of China (English)

    Duan Yao-Yong; Guo Yong-Hui; Wang Wen-Sheng; Qiu Ai-Ci

    2005-01-01

    A two-dimensional, three-temperature radiation magneto-hydrodynamics model is applied to the investigation of evolutional trends in x-ray radiation power, energy, peak plasma temperature and density as functions of drive current rise-time and initial load density distribution by using the typical experimental parameters of tungsten wire-array Z-pinch on the Qiangguang-Ⅰ generator. The numerical results show that as the drive current rise-time is shortened, x-ray radiation peak power, energy, peak plasma density and peak ion temperature increase approximately linearly, but among them the x-ray radiation peak power increases more quickly. As the initial plasma density distribution in the radial direction becomes gradually flattened, the peak radiation power and the peak ion-temperature almost exponentially increase, while the radiation energy and the peak plasma density change only a little. The main effect of shortening drive current rise-time is to enhance compression of plasma, and the effect of flattening initial load density distribution in the radial direction is to raise the plasma temperature. Both of the approaches elevate the x-ray peak radiation power.

  1. From RISING to the DESPEC fast-timing project within NUSTAR at FAIR: Sub-nanosecond nuclear timing spectroscopy with LaBr3 scintillators

    International Nuclear Information System (INIS)

    Regan, P.H.

    2012-01-01

    This paper summarises a presentation given at the IRRMA8 conference in June 2011 which reviewed briefly the topic of current research studies in the evolution of nuclear structure with changing proton and neutron numbers. A short review of relevant contemporary spectroscopic studies of the structure of nuclei with highly exotic N/Z ratios using projectile fragmentation and fission reactions is given, together with an overview of some of the physics research aims to be attacked using the proposed Decay Spectroscopy (DESPEC) LaBr 3 Fast-Timing gamma-ray array for the NUSTAR project at the upcoming Facility for Anti-Proton and Ion Research (FAIR). Examples of recent results using both ‘isomer’ and β − -delayed gamma-ray decay measurements with the Stopped RISING hyper-pure germanium array at GSI are summarised and used to highlight some of the fundamental physics studies which are expected to become available in this area of research in the coming decade. Examples of the performance of cerium-doped LaBr 3 detectors from ‘in-beam’ test experiments are presented together with initial plans for the geometry of the planned multi-detector LaBr 3 (Ce) array for DESPEC. - Highlights: ► The paper presents an overview of nuclear excitation systematics in even–even nuclei. ► The paper gives a description of the Stopped RISING gamma-ray spectrometer. ► This paper gives some of the recent scientific results in nuclear spectroscopy of exotic nuclei. ► The paper shows the use of halide scintillation detectors for gamma-ray decay studies of nuclei. ► This paper shows the use of LaBr 3 detectors to nuclear excited state lifetimes in the ns regime.

  2. Photoperiodic time measurement in insects

    Czech Academy of Sciences Publication Activity Database

    Doležel, David

    2015-01-01

    Roč. 7, Feb 02 (2015), s. 98-103 ISSN 2214-5745 R&D Projects: GA ČR GC14-32654J; GA MŠk LH14029 Institutional support: RVO:60077344 Keywords : photoperiodic time Subject RIV: ED - Physiology Impact factor: 2.719, year: 2015 http://www.sciencedirect.com/science/article/pii/S2214574514001576

  3. Time expansion chamber and single ionization cluster measurement

    International Nuclear Information System (INIS)

    Walenta, A.H.

    1978-10-01

    The time expansion chamber (TEC), a new type of drift chamber, allows the measurement of microscopic details of ionization. The mean drift time interval from subsequent sngle ionization clusters of a relativistic particle in the TEC can be made large enough compared to the width of a anode signal to allow the recording of the clusters separately. Since single primary electrons can be detected, the cluster counting would allow an improved particle separation using the relativistic rise of primary ionization. In another application, very high position accuracy for track detectors or improved energy resolution may be obtained. Basic ionization phenomena and drift properties can be measured at the single electron level

  4. The rise of global warming skepticism: exploring affective image associations in the United States over time.

    Science.gov (United States)

    Smith, Nicholas; Leiserowitz, Anthony

    2012-06-01

    This article explores how affective image associations to global warming have changed over time. Four nationally representative surveys of the American public were conducted between 2002 and 2010 to assess public global warming risk perceptions, policy preferences, and behavior. Affective images (positive or negative feelings and cognitive representations) were collected and content analyzed. The results demonstrate a large increase in "naysayer" associations, indicating extreme skepticism about the issue of climate change. Multiple regression analyses found that holistic affect and "naysayer" associations were more significant predictors of global warming risk perceptions than cultural worldviews or sociodemographic variables, including political party and ideology. The results demonstrate the important role affective imagery plays in judgment and decision-making processes, how these variables change over time, and how global warming is currently perceived by the American public. © 2012 Society for Risk Analysis.

  5. Improvement in limit of detection in particle induced X-ray emission by means of rise time and pulse shape discrimination

    Energy Technology Data Exchange (ETDEWEB)

    Papp, Tibor E-mail: tibpapp@netscape.nettibpapp@yahoo.ca; Lakatos, Tamas; Nejedly, Zdenek; Campbell, John L

    2002-04-01

    A digital signal processor, based upon high-rate sampling of the preamplifier output, and equipped with rise time and pulse shape discrimination, has been tested in three situations. This processor provided significant improvement of particle induced X-ray emission and X-ray fluorescence detection limits over the state of the art analog processors, depending on the energy and intensity distribution of the X-ray spectra. Additionally it had a superior performance when measurements were performed in an environment of large electronic noise and in large nuclear background environment. It has also improved the reduction of several artifacts in X-ray spectra.

  6. Overdiagnosis and rising rate of obstetric anal sphincter injuries (OASIS): time for reappraisal.

    Science.gov (United States)

    Sioutis, D; Thakar, R; Sultan, A H

    2017-11-01

    To determine the accuracy of clinical diagnosis of obstetric anal sphincter injuries (OASIS) using three-dimensional (3D) endoanal ultrasound (EA-US) and to compare symptoms and anal manometry measurements between women with anal sphincters adequately repaired and those with persistent anal sphincter defects. The EA-US images of women with clinically diagnosed and repaired OASIS, defined as third- or fourth-degree perineal tear, who attended the perineal clinic at Croydon University Hospital over a 10-year period (2003-2013) were reanalyzed by a single expert blind to symptoms and the results of clinical examination. St Mark's Incontinence Scores (SMIS) and anal manometry measurements were obtained and compared between women with an intact anal sphincter and those with an anal sphincter scar and between those with an intact anal sphincter and those with a defect. Anal manometry measurements were compared between women with an external anal sphincter (EAS) defect and those with an internal anal sphincter (IAS) defect. The images of 908 women were reanalyzed. No evidence of OASIS was found in 64 (7.0%) women, an EAS scar alone was detected in 520 (57.3%) and an anal sphincter defect in 324 (35.7%). Of the 324 women with a defect, 112 had an EAS defect, 90 had an IAS defect and 122 had a combined IAS and EAS defect. SMIS results were significantly higher in women with an anal sphincter defect compared with those with no evidence of OASIS (P = 0.018), but there was no significant difference in scores between women with an intact sphincter and those with an EAS scar only. Women with a defect had a significantly lower maximum resting pressure (median (range), 44 (8-106) vs 55 (29-86) mmHg; P 40) vs 25 (10-40) mm; P = 0.003). Seven percent of women with a clinical diagnosis of OASIS were wrongly diagnosed. We believe that this rate may differ from that of other units but training methods and competency assessment tools for the diagnosis and repair of OASIS need

  7. Measuring device for control rod driving time

    International Nuclear Information System (INIS)

    Tanaka, Kazuhiko; Hanabusa, Masatoshi.

    1993-01-01

    The present invention concerns a measuring device for control driving time having a function capable of measuring a selected control rod driving time and measuring an entire control rod driving time simultaneously. A calculation means and a store means for the selected rod control rod driving time, and a calculation means and a store means for the entire control rod driving time are disposed individually. Each of them measures the driving time and stores the data independent of each other based on a selected control rod insert ion signal and an entire control rod insertion signal. Even if insertion of selected and entire control rods overlaps, each of the control rod driving times can be measured reliably to provide an advantageous effect capable of more accurately conducting safety evaluation for the nuclear reactor based on the result of the measurement. (N.H.)

  8. The rise and fall of red cell mass measurement in polycythemia vera.

    Science.gov (United States)

    Tefferi, Ayalew

    2005-05-01

    The total blood volume (BV) consists of the part occupied by red blood cells (RBC), which is referred to as red cell mass (RCM), and that occupied by plasma (ie, plasma volume). Quantitative laboratory measurements that are pertinent to RBC, including RBC count, hematocrit (Hct), and hemoglobin (Hgb) are expressed in reference to a given volume of whole blood and are therefore influenced by plasma volume. Consequently, a "direct" RCM measurement has been promoted as a more accurate indicator of the body's red cell content. In accordance with this view, an international group of investigators, then identified as the Polycythemia Vera Study Group (PVSG), recommended that RCM be measured and only if elevated should a patient be considered for participation in a series of clinical trials in PV that were conducted more than 30 years ago. By default, the 'study eligibility' criteria used in these studies became 'diagnostic' criteria without any systematic evaluation for diagnostic accuracy. Furthermore, over the years, it has become evident that RCM measurement is a cumbersome and costly test that is also suboptimal in its diagnostic accuracy. As a result, the specific procedure has been abandoned by the majority of hematologists in certain countries and instead physicians are increasingly using bone marrow histology, serum erythropoietin level, and other disease-characteristic biologic markers as diagnostic tools.

  9. An Empirical Fitting Method to Type Ia Supernova Light Curves. III. A Three-parameter Relationship: Peak Magnitude, Rise Time, and Photospheric Velocity

    Science.gov (United States)

    Zheng, WeiKang; Kelly, Patrick L.; Filippenko, Alexei V.

    2018-05-01

    We examine the relationship between three parameters of Type Ia supernovae (SNe Ia): peak magnitude, rise time, and photospheric velocity at the time of peak brightness. The peak magnitude is corrected for extinction using an estimate determined from MLCS2k2 fitting. The rise time is measured from the well-observed B-band light curve with the first detection at least 1 mag fainter than the peak magnitude, and the photospheric velocity is measured from the strong absorption feature of Si II λ6355 at the time of peak brightness. We model the relationship among these three parameters using an expanding fireball with two assumptions: (a) the optical emission is approximately that of a blackbody, and (b) the photospheric temperatures of all SNe Ia are the same at the time of peak brightness. We compare the precision of the distance residuals inferred using this physically motivated model against those from the empirical Phillips relation and the MLCS2k2 method for 47 low-redshift SNe Ia (0.005 Ia in our sample with higher velocities are inferred to be intrinsically fainter. Eliminating the high-velocity SNe and applying a more stringent extinction cut to obtain a “low-v golden sample” of 22 SNe, we obtain significantly reduced scatter of 0.108 ± 0.018 mag in the new relation, better than those of the Phillips relation and the MLCS2k2 method. For 250 km s‑1 of residual peculiar motions, we find 68% and 95% upper limits on the intrinsic scatter of 0.07 and 0.10 mag, respectively.

  10. Time measurements for thermalequilibrium in spodumene crystals

    International Nuclear Information System (INIS)

    Fujii, A.T.; Isotani, S.

    1982-01-01

    Experiments for measurement of time taken to reach thermal equilibrium in Spodumene crystals - 2mm to 5,4mm thick - in the temperature range 100 0 to 250 0 C are described. The measurements indicate a linear relationship between time and thickenes for heating as well as for cooling. Difference in thermal equilibrium time for heating and for cooling is about of 20 seconds. (author) [pt

  11. Is direct measurement of time possible?

    Science.gov (United States)

    Reynolds, Thomas

    2017-08-01

    Is direct measurement of time possible? The answer to this question may depend upon how one understands time. Is time an essential constituent of physical reality? Or is what scientists are talking about when they use the symbol ‘t’ or the word ‘time’ an human cultural construct, as the Chief of the USA NIST Divisions of Time and Frequency and of Quantum Physics has suggested. Few aspects of physics do not reference activity to time, but many discussions within either view of time seem to use one same, largely traditional, language of time. Briefly considering the question of measurement, including from a formal measure-theoretic point of view, clarifies the situation.

  12. An USB-based time measurement system

    International Nuclear Information System (INIS)

    Qin Xi; Liu Shubin; An Qi

    2010-01-01

    In this paper,we report the electronics of a timing measurement system of PTB(portable TDC board), which is a handy tool based on USB interface, customized for high precision time measurements without any crates. The time digitization is based on the High Performance TDC Chip (HPTDC). The real-time compensation for HPTDC outputs and the USB master logic are implemented in an ALTERA's Cyclone FPGA. The architecture design and logic design are described in detail. Test of the system showed a time resolution of 13.3 ps. (authors)

  13. Additive measures of travel time variability

    DEFF Research Database (Denmark)

    Engelson, Leonid; Fosgerau, Mogens

    2011-01-01

    This paper derives a measure of travel time variability for travellers equipped with scheduling preferences defined in terms of time-varying utility rates, and who choose departure time optimally. The corresponding value of travel time variability is a constant that depends only on preference...... parameters. The measure is unique in being additive with respect to independent parts of a trip. It has the variance of travel time as a special case. Extension is provided to the case of travellers who use a scheduled service with fixed headway....

  14. NOAA Laboratory for Satellite Altimetry Sea Level Rise Products: Global and regional sea level time series and trend maps for the major ocean basins and marginal seas, based on measurements from satellite radar altimeters, from 1992-12-17 to 2017-08-11 (NCEI Accession 0125535)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This archival package contains global and regional mean sea level time series and trend maps calculated on a continual basis since December 1992 by Laboratory for...

  15. Transit time measurement of Juqueri river waters

    International Nuclear Information System (INIS)

    Plata Bedmar, E.; Garcia A, E.; Albuquerque, A.M. de; Sanchez, W.

    1975-01-01

    The time of travel of the Juqueri River water through the east branch of the Pirapora Reservoir was measured using radioactive tracers (6 Ci 131 I in Kl Solution). The changes in Juqueri River flow rate were also measured during the run. The center of mass of the radioactive cloud was used for the time of travel calculations. Six measurements of the Juqueri River flow rate were perfomed in different days, using the total count method. Fifty, millicuries of 131 I were used in each run. The results of time travel obtained under non-steady conditions, and their correction for steady state are also discussed

  16. Nanosecond time measurements of single pulse

    International Nuclear Information System (INIS)

    Xing Jingyuan; Cheng Shiyuan

    1986-01-01

    This report mainly describes the principle specification of circuit design and time-interval calibrations of model SHS 500 time-to-digital converter. Its range is 12 to 500 ns, with six ranges: 50, 100, 200, 300, 400 and 500 ns. The precision of measured time-interval is 0.3% of full scale and time resolution is 0.1% of full scale

  17. Double threshold discriminator for timing measurements

    International Nuclear Information System (INIS)

    Frolov, A.R.; Oslopova, T.V.; Pestov, Yu.N.

    1995-01-01

    The new type of a discriminator is based on the idea of simultaneous time measurements at two different thresholds for each pulse. Instead of using two independent electronic TDC channels this discriminator produces an output pulse with the timing taking into account the information from two time measurements ''on-line''. The operation principle, analytical calculations and experimental results are presented. The time walk of the discriminator at the level of 10 ps in the range of the input pulse height of 0.2-1.5 V has been obtained. ((orig.))

  18. Real time refractive index measurement by ESPI

    International Nuclear Information System (INIS)

    Torroba, R.; Joenathan, C.

    1991-01-01

    In this paper a method to measure refractive index variations in real time is reported. A technique to introduce reference fringes in real time is discussed. Both the theoretical and experimental results are presented and an example with phase shifting is given. (author). 8 refs, 5 figs

  19. Luminescence rise time in self-activated PbWO4 and Ce-doped Gd3Al2Ga3O12 scintillation crystals

    CERN Document Server

    E. Auffray; A. Borisevich; V. Gulbinas; A. Fedorov; M. Korjik; M.T. Lucchini; V. Mechinsky; S. Nargelas; E. Songaila; G. Tamulaitis; A. Vaitkevičius; S. Zazubovich

    2016-01-01

    The time resolution of scintillation detectors of ionizing radiation is one of the key parameters sought for in the current and future high-energy physics experiments. This study is encouraged by the necessity to find novel detection methods enabling a sub-10-ps time resolution in scintillation detectors and is focused on the exploitation of fast luminescence rise front. Time-resolved photoluminescence (PL) spectroscopy and thermally stimulated luminescence techniques have been used to study two promising scintillators: self-activated lead tungstate (PWO, PbWO4) and Ce-doped gadolinium aluminum gallium garnet (GAGG, Gd3Al2Ga3O12). A sub-picosecond PL rise time is observed in PWO, while longer processes in the PL response in GAGG:Ce are detected and studied. The mechanisms responsible for the PL rise time in self-activated and doped scintillators are under discussion.

  20. Time-resolved measurements of luminescence

    Energy Technology Data Exchange (ETDEWEB)

    Collier, Bradley B. [Department of Biomedical Engineering, 408 Mechanical Engineering Office Building, Spence Street, Texas A and M University, College Station, TX 77843 (United States); McShane, Michael J., E-mail: mcshane@tamu.edu [Department of Biomedical Engineering, 408 Mechanical Engineering Office Building, Spence Street, Texas A and M University, College Station, TX 77843 (United States); Materials Science and Engineering Program, 408 Mechanical Engineering Office Building, Spence Street, Texas A and M University, College Station, TX 77843 (United States)

    2013-12-15

    Luminescence sensing and imaging has become more widespread in recent years in a variety of industries including the biomedical and environmental fields. Measurements of luminescence lifetime hold inherent advantages over intensity-based response measurements, and advances in both technology and methods have enabled their use in a broader spectrum of applications including real-time medical diagnostics. This review will focus on recent advances in analytical methods, particularly calculation techniques, including time- and frequency-domain lifetime approaches as well as other time-resolved measurements of luminescence. -- Highlights: • Developments in technology have led to widespread use of luminescence lifetime. • Growing interest for sensing and imaging applications. • Recent advances in approaches to lifetime calculations are reviewed. • Advantages and disadvantages of various methods are weighed. • Other methods for measurement of luminescence lifetime also described.

  1. Time-resolved measurements of luminescence

    International Nuclear Information System (INIS)

    Collier, Bradley B.; McShane, Michael J.

    2013-01-01

    Luminescence sensing and imaging has become more widespread in recent years in a variety of industries including the biomedical and environmental fields. Measurements of luminescence lifetime hold inherent advantages over intensity-based response measurements, and advances in both technology and methods have enabled their use in a broader spectrum of applications including real-time medical diagnostics. This review will focus on recent advances in analytical methods, particularly calculation techniques, including time- and frequency-domain lifetime approaches as well as other time-resolved measurements of luminescence. -- Highlights: • Developments in technology have led to widespread use of luminescence lifetime. • Growing interest for sensing and imaging applications. • Recent advances in approaches to lifetime calculations are reviewed. • Advantages and disadvantages of various methods are weighed. • Other methods for measurement of luminescence lifetime also described

  2. Measuring multiscaling in financial time-series

    International Nuclear Information System (INIS)

    Buonocore, R.J.; Aste, T.; Di Matteo, T.

    2016-01-01

    We discuss the origin of multiscaling in financial time-series and investigate how to best quantify it. Our methodology consists in separating the different sources of measured multifractality by analyzing the multi/uni-scaling behavior of synthetic time-series with known properties. We use the results from the synthetic time-series to interpret the measure of multifractality of real log-returns time-series. The main finding is that the aggregation horizon of the returns can introduce a strong bias effect on the measure of multifractality. This effect can become especially important when returns distributions have power law tails with exponents in the range (2, 5). We discuss the right aggregation horizon to mitigate this bias.

  3. Time-Resolved Surface Temperature Measurement for Pulsed Ablative Thrusters

    National Research Council Canada - National Science Library

    Antonsen, Erik

    2003-01-01

    .... The diagnostic draws on heritage from the experimental dynamic crack propagation community which has used photovoltaic infrared detectors to measure temperature rise in materials in the process of fracture...

  4. The changing timing of births in Iran: an explanation of the rise and fall in fertility after the 1979 Islamic Revolution.

    Science.gov (United States)

    Erfani, Amir; McQuillan, Kevin

    2014-01-01

    Studies exploring the course of period fertility in Iran after the 1979 Islamic Revolution have not examined systematically the role played by changes in the timing of births. Using retrospective data from the 2000 Iran Demographic and Health Survey and frailty hazard models, this study finds that the rise in fertility in the early 1980s was due to faster transitions to the first birth among all social groups of women and to the fourth birth largely among illiterate and less educated women. In contrast, the rapid fertility decline after 1985 is attributed to slower transition to successive births, especially to the second, third, and fourth births. These findings point to the importance of education and contraceptive use (measured by length of previous birth interval) as key determinants of birth timing in Iran. Interaction between age at marriage and education positively influenced the timing of births, with stronger effects among highly educated women, suggesting that the onset of rapid fertility decline was likely driven by these highly educated women. Another interaction between the gender of prior children and education shows that birth timing, even among highly educated women, appears to have been influenced by son preference in Iran.

  5. Minimization of the external heating power by long fusion power rise-up time for self-ignition access in the helical reactor FFHR2m

    International Nuclear Information System (INIS)

    Mitarai, O.; Sagara, A.; Chikaraishi, H.; Imagawa, S.; Shishkin, A.A.; Motojima, O.

    2006-10-01

    Minimization of the external heating power to access self-ignition is advantageous to increase the reactor design flexibility and to reduce the capital and operating costs of the plasma heating device in a helical reactor. In this work we have discovered that a larger density limit leads to a smaller value of the required confinement enhancement factor, lower density limit margin reduces the external heating power, and over 300 s of the fusion power rise-up time makes it possible to reach a minimized heating power. While the fusion power rise-up time in a tokamak is limited by the OH transformer flux or the current drive capability, any fusion power rise-up time can be employed in a helical reactor for reducing the thermal stresses of the blanket and shields, because the confinement field is generated by the external helical coils. (author)

  6. Contemporary sea level rise.

    Science.gov (United States)

    Cazenave, Anny; Llovel, William

    2010-01-01

    Measuring sea level change and understanding its causes has considerably improved in the recent years, essentially because new in situ and remote sensing observations have become available. Here we report on most recent results on contemporary sea level rise. We first present sea level observations from tide gauges over the twentieth century and from satellite altimetry since the early 1990s. We next discuss the most recent progress made in quantifying the processes causing sea level change on timescales ranging from years to decades, i.e., thermal expansion of the oceans, land ice mass loss, and land water-storage change. We show that for the 1993-2007 time span, the sum of climate-related contributions (2.85 +/- 0.35 mm year(-1)) is only slightly less than altimetry-based sea level rise (3.3 +/- 0.4 mm year(-1)): approximately 30% of the observed rate of rise is due to ocean thermal expansion and approximately 55% results from land ice melt. Recent acceleration in glacier melting and ice mass loss from the ice sheets increases the latter contribution up to 80% for the past five years. We also review the main causes of regional variability in sea level trends: The dominant contribution results from nonuniform changes in ocean thermal expansion.

  7. Uncertainties for pressure-time efficiency measurements

    OpenAIRE

    Ramdal, Jørgen; Jonsson, Pontus; Dahlhaug, Ole Gunnar; Nielsen, Torbjørn; Cervantes, Michel

    2010-01-01

     In connection with the pressure-time project at the Norwegian University of Science and Technology and Luleå University of Technology, a number of tests with the pressure-time method have been performed at the Waterpower Laboratory in Trondheim, Norway. The aim is to lower the uncertainty and improve usability of the method. Also a field test at the Anundsjoe power plant in Sweden has been performed. The pressure-time measurement is affected by random uncertainty. To minimize the effect of t...

  8. Confirming the cognition of rising scores: Fox and Mitchum (2013) predicts violations of measurement invariance in series completion between age-matched cohorts.

    Science.gov (United States)

    Fox, Mark C; Mitchum, Ainsley L

    2014-01-01

    The trend of rising scores on intelligence tests raises important questions about the comparability of variation within and between time periods. Descriptions of the processes that mediate selection of item responses provide meaningful psychological criteria upon which to base such comparisons. In a recent paper, Fox and Mitchum presented and tested a cognitive theory of rising scores on analogical and inductive reasoning tests that is specific enough to make novel predictions about cohort differences in patterns of item responses for tests such as the Raven's Matrices. In this paper we extend the same proposal in two important ways by (1) testing it against a dataset that enables the effects of cohort to be isolated from those of age, and (2) applying it to two other inductive reasoning tests that exhibit large Flynn effects: Letter Series and Word Series. Following specification and testing of a confirmatory item response model, predicted violations of measurement invariance are observed between two age-matched cohorts that are separated by only 20 years, as members of the later cohort are found to map objects at higher levels of abstraction than members of the earlier cohort who possess the same overall level of ability. Results have implications for the Flynn effect and cognitive aging while underscoring the value of establishing psychological criteria for equating members of distinct groups who achieve the same scores.

  9. Confirming the cognition of rising scores: Fox and Mitchum (2013 predicts violations of measurement invariance in series completion between age-matched cohorts.

    Directory of Open Access Journals (Sweden)

    Mark C Fox

    Full Text Available The trend of rising scores on intelligence tests raises important questions about the comparability of variation within and between time periods. Descriptions of the processes that mediate selection of item responses provide meaningful psychological criteria upon which to base such comparisons. In a recent paper, Fox and Mitchum presented and tested a cognitive theory of rising scores on analogical and inductive reasoning tests that is specific enough to make novel predictions about cohort differences in patterns of item responses for tests such as the Raven's Matrices. In this paper we extend the same proposal in two important ways by (1 testing it against a dataset that enables the effects of cohort to be isolated from those of age, and (2 applying it to two other inductive reasoning tests that exhibit large Flynn effects: Letter Series and Word Series. Following specification and testing of a confirmatory item response model, predicted violations of measurement invariance are observed between two age-matched cohorts that are separated by only 20 years, as members of the later cohort are found to map objects at higher levels of abstraction than members of the earlier cohort who possess the same overall level of ability. Results have implications for the Flynn effect and cognitive aging while underscoring the value of establishing psychological criteria for equating members of distinct groups who achieve the same scores.

  10. Boltzmann babies in the proper time measure

    Energy Technology Data Exchange (ETDEWEB)

    Bousso, Raphael; Bousso, Raphael; Freivogel, Ben; Yang, I-Sheng

    2007-12-20

    After commenting briefly on the role of the typicality assumption in science, we advocate a phenomenological approach to the cosmological measure problem. Like any other theory, a measure should be simple, general, well defined, and consistent with observation. This allows us to proceed by elimination. As an example, we consider the proper time cutoff on a geodesic congruence. It predicts that typical observers are quantum fluctuations in the early universe, or Boltzmann babies. We sharpen this well-known youngness problem by taking into account the expansion and open spatial geometry of pocket universes. Moreover, we relate the youngness problem directly to the probability distribution for observables, such as the temperature of the cosmic background radiation. We consider a number of modifications of the proper time measure, but find none that would make it compatible with observation.

  11. Time-resolved absorption measurements on OMEGA

    International Nuclear Information System (INIS)

    Jaanimagi, P.A.; DaSilva, L.; Delettrez, J.; Gregory, G.G.; Richardson, M.C.

    1986-01-01

    Time-resolved measurements of the incident laser light that is scattered and/or refracted from targets irradiated by the 24 uv-beam OMEGA laser at LLE, have provided some interesting features related to time-resolved absorption. The decrease in laser absorption characteristic of irradiating a target that implodes during the laser pulse has been observed. The increase in absorption expected as the critical density surface moves from a low to a high Z material in the target has also been noted. The detailed interpretation of these results is made through comparisons with simulation using the code LILAC, as well as with streak data from time-resolved x-ray imaging and spectroscopy. In addition, time and space-resolved imaging of the scattered light yields information on laser irradiation uniformity conditions on the target. The report consists of viewgraphs

  12. Green's function for a switched plasma medium and a perturbation technique for the study of wave propagation in a transient plasma with a small rise time

    International Nuclear Information System (INIS)

    Kalluri, D.K.

    1996-01-01

    The main effect of switching a medium (creating a temporal discontinuity in the properties of a medium) is the splitting of the source (incident) wave into new waves whose frequencies are different. Lightning induced effects in the ionosphere cause a temporary enhancement of ionization. Such transient plasmas have a time-varying plasma frequency ω p (t) with a rise time T r . If the period t 0 of a source wave existing before the transient effect begins is much larger than the rise time, the ionization change may be idealized as a sudden switching of the medium. The solution to this initial value problem with a step-change in the electron density profile is known and this profile will be considered as a reference profile. The topic of this paper is the solution of the initial value problem when t 0 is comparable to the rise time T r . The initial motivation for investigating the problem is given below. There is considerable interest in the ionospheric physics community to investigate the recently discovered Sprites phenomenon which are red emissions in the lower D region induced by the lightning discharges from a cloud to the ground. The preliminary indications are that the Sprite is a plasma with electron density enhanced by about 10 1 to 10 3 /cc in a rise time of about 100 micros

  13. Time response measurements of LASL diagnostic detectors

    International Nuclear Information System (INIS)

    Hocker, L.P.

    1970-07-01

    The measurement and data analysis techniques developed under the Los Alamos Scientific Laboratory's detector improvement program were used to characterize the time and frequency response of selected LASL Compton, fluor-photodiode (NPD), and fluor-photomultiplier (NPM) diagnostic detectors. Data acquisition procedures and analysis methods presently in use are summarized, and detector time and frequency data obtained using the EG and G/AEC electron linear accelerator fast pulse (approximately 50 psec FWHM) as the incident radiation driving function are presented. (U.S.)

  14. The rise of non-financial performance measures in annual reports. An analysis of ATX-listed companies

    Directory of Open Access Journals (Sweden)

    Juergen Muehlbacher

    2016-05-01

    Full Text Available Purpose of the article: In the past, annual reports only included financial measures. More recently, this shareholder value approach has been criticized of leading to a strategic short-term orientation. Consequently, the use of strategic performance measurement systems (SPMSs, namely the Balanced Scorecard (BSC, is proposed to communicate non-financial measures to investors and stakeholders. Besides the distribution of critical information, the disclosure of non-financial measures should strengthen the employees’ commitment to the long-term strategy. The purpose of the article is thus to reveal whether Austrian companies disclose their strategic performance measures in their annual reports. Methodology/methods: Two observation points, 2002 and 2012, were chosen to analyse the annual reports of companies listed on the ATX. This period of time allows to observe changes as well as new trends. The annual reports have been downloaded from the companies’ homepages or received via email or post. A document and content analysis, followed by a frequency analysis, has been applied to identify several non-financial measures with regard to the following BSC-derived perspectives: Customer perspective, internal business perspective and innovation and learning perspective. Scientific aim: The scientific aim of the following study is to examine the extent to which non-financial performance measures are displayed in annual reports. Findings: The analysis of the annual reports showed a tremendous increase in non-financial measures in the time period between 2002 and 2012, which solely arose from the augmented disclosure activities of the innovation and learning perspective. On the other hand, the customer and internal perspectives decreased in importance. Moreover, the top ten measures in 2002 have changed and are dominated by diversity and environmental issues in the year 2012. Conclusions: Similar findings in the literature as well as the influence of legal

  15. Time-resolved brightness measurements by streaking

    Science.gov (United States)

    Torrance, Joshua S.; Speirs, Rory W.; McCulloch, Andrew J.; Scholten, Robert E.

    2018-03-01

    Brightness is a key figure of merit for charged particle beams, and time-resolved brightness measurements can elucidate the processes involved in beam creation and manipulation. Here we report on a simple, robust, and widely applicable method for the measurement of beam brightness with temporal resolution by streaking one-dimensional pepperpots, and demonstrate the technique to characterize electron bunches produced from a cold-atom electron source. We demonstrate brightness measurements with 145 ps temporal resolution and a minimum resolvable emittance of 40 nm rad. This technique provides an efficient method of exploring source parameters and will prove useful for examining the efficacy of techniques to counter space-charge expansion, a critical hurdle to achieving single-shot imaging of atomic scale targets.

  16. An Enterprise Model of Rising Ship Costs: Loss of Learning Due to Time between Ships and Labor Force Instability

    OpenAIRE

    Summerville, Jessica R.; Cullis, Bethia L.; Druker, Eric R.; Rutledge, Gabriel B.; Braxton, Peter J.; Coleman, Richard L.

    2007-01-01

    Proceedings Paper (for Acquisition Research Program) Since the end of the Cold War, the perceived need for Navy ships has dropped, and so the shipbuilding budget has dropped. Seemingly coincidental with this budgetary pressure, and perversely aggravating the problem, ship costs began to rise steeply. We will set aside that ships have grown in weight by about three percent per year since World War II and that ever-more weapon systems are being put into them, and confine ourselves to discu...

  17. Flood Protection in Venice under Conditions of Sea-Level Rise: An Analysis of Institutional and Technical Measures

    NARCIS (Netherlands)

    Munaretto, S.; Vellinga, P.; Tobi, H.

    2012-01-01

    It is widely acknowledged that in times of climate change loss of coastal resources and risk for human life can be minimized by implementing adaptation strategies. Such strategies need to encompass a balanced mix of non-structural (institutional) and structural (technical) measures based on sound

  18. Rising equity

    International Nuclear Information System (INIS)

    Burr, M.T.

    1992-01-01

    This article reports on the results of a financial rankings survey of the independent energy industry indicating that lenders and investors provided more than five billion dollars in capital for new, private power projects during the first six months of 1992. The topics of the article include rising equity requirements, corporate finance, mergers and acquisitions, project finance investors, revenue bonds, project finance lenders for new projects, project finance lenders for restructurings, and project finance advisors

  19. Are anomalously short tunnelling times measurable?

    International Nuclear Information System (INIS)

    Delgado, V.; Muga, J.G.

    1996-01-01

    Low and Mende have analyzed the conditions that would make possible an actual measurement of an anomalously short traversal time through a potential barrier concluding that such a measurement cannot be made because it is not possible to describe the tunnelling of a wave packet initially close to the barrier by the open-quote open-quote usual wave packet space time analysis close-quote close-quote. We complement this work in several ways: It is argued that the described failure of the usual formalism occurs under a set of too restrictive conditions, some of them not physically motivated, so it does not necessarily imply the impossibility of such a measurement. However, by retaining only conditions well motivated on physical grounds we have performed a systematic numerical check which shows that the conclusion by Low and Mende is indeed generally valid. It is shown that, as speculated by Low and Mende, the process is dominated by over the barrier transmission. Copyright copyright 1996 Academic Press, Inc

  20. Time Resolved Deposition Measurements in NSTX

    International Nuclear Information System (INIS)

    Skinner, C.H.; Kugel, H.; Roquemore, A.L.; Hogan, J.; Wampler, W.R.

    2004-01-01

    Time-resolved measurements of deposition in current tokamaks are crucial to gain a predictive understanding of deposition with a view to mitigating tritium retention and deposition on diagnostic mirrors expected in next-step devices. Two quartz crystal microbalances have been installed on NSTX at a location 0.77m outside the last closed flux surface. This configuration mimics a typical diagnostic window or mirror. The deposits were analyzed ex-situ and found to be dominantly carbon, oxygen, and deuterium. A rear facing quartz crystal recorded deposition of lower sticking probability molecules at 10% of the rate of the front facing one. Time resolved measurements over a 4-week period with 497 discharges, recorded 29.2 (micro)g/cm 2 of deposition, however surprisingly, 15.9 (micro)g/cm 2 of material loss occurred at 7 discharges. The net deposited mass of 13.3 (micro)g/cm 2 matched the mass of 13.5 (micro)g/cm 2 measured independently by ion beam analysis. Monte Carlo modeling suggests that transient processes are likely to dominate the deposition

  1. Shock timing measurements in DT ice layers

    Science.gov (United States)

    Robey, H. F.; Celliers, P. M.; Moody, J. D.; Sater, J.; Parham, T.; Kozioziemski, B.; Dylla-Spears, R. J.; Ross, J. S.; Lepape, S.; Ralph, J. E.; Berzak Hopkins, L. F.; Kroll, J. J.; Yoxall, B. E.; Hamza, A. V.; Boehly, T. R.; Nikroo, A.; Landen, O. L.; Edwards, M. J.

    2013-10-01

    Shock timing experiments on the National Ignition Facility (NIF) are routinely conducted using the keyhole target geometry, in which the strength and timing of multiple shocks are measured in a liquid-deuterium (D2) filled capsule interior. These targets have recently been modified to improve the surrogacy to ignition implosions by replacing the standard, continuous liquid D2 capsule fill with a deuterium-tritium (DT) ice layer with a central DT gas fill. These experiments remove any possible material surrogacy difference between D2 and DT as well as incorporating the physics of multiple shock release and recompression events from an ice layer of finite thickness, an effect that is absent in the liquid-filled targets. Experimental results and comparisons with numerical simulation are presented. Prepared by LLNL under Contract DE-AC52-07NA27344.

  2. Analysis in measurements of gastric emptying time

    International Nuclear Information System (INIS)

    Lee, Choon Ho; Lee, Man Koo

    1997-01-01

    Scintigraphic measurement of gastric emptying time has been reported to be influenced by the variation in depth of radionuclide within the stomach. This study was designed to clarify whether a part of the variability in gastric emptying could be ascribed to a relationship between anterior image, the total anteroposterior image and the tissue attenuation correction(geometric mean). A dual-head scintillation camera(ADAC, USA) was used to investigate effect of such changes. We were performed 16 normal subject gastric emptying studies with 99 mTC labelled scramble egg, milk and solid meal(610 Kcal, 300 g). The results are as follows; On anterior image, T 1/2 emptying time was delayed by 5 min, 6.5%(range : 3 ∼ 18 min, 5∼31.4%) compared with the geometric mean. But there was no different gastric emptying time between the total anteroposterior image and geometric mean. Therefore, if will be useful to use the method of geometric mean or the total anteroposterior image to evaluate the gastric emptying time accurately

  3. Analysis in measurements of gastric emptying time

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Ho [College of Medicine, Wonkwang Univ., Iksan (Korea, Republic of); Lee, Man Koo [Wonkwang Health Science College, Iksan (Korea, Republic of)

    1997-02-01

    Scintigraphic measurement of gastric emptying time has been reported to be influenced by the variation in depth of radionuclide within the stomach. This study was designed to clarify whether a part of the variability in gastric emptying could be ascribed to a relationship between anterior image, the total anteroposterior image and the tissue attenuation correction(geometric mean). A dual-head scintillation camera(ADAC, USA) was used to investigate effect of such changes. We were performed 16 normal subject gastric emptying studies with {sup 99}mTC labelled scramble egg, milk and solid meal(610 Kcal, 300 g). The results are as follows; On anterior image, T{sub 1/2} emptying time was delayed by 5 min, 6.5%(range : 3 {approx} 18 min, 5{approx}31.4%) compared with the geometric mean. But there was no different gastric emptying time between the total anteroposterior image and geometric mean. Therefore, if will be useful to use the method of geometric mean or the total anteroposterior image to evaluate the gastric emptying time accurately.

  4. Time-Lapse Measurement of Wellbore Integrity

    Science.gov (United States)

    Duguid, A.

    2017-12-01

    Well integrity is becoming more important as wells are used longer or repurposed. For CO2, shale gas, and other projects it has become apparent that wells represent the most likely unintended migration pathway for fluids out of the reservoir. Comprehensive logging programs have been employed to determine the condition of legacy wells in North America. These studies provide examples of assessment technologies. Logging programs have included pulsed neutron logging, ultrasonic well mapping, and cement bond logging. While these studies provide examples of what can be measured, they have only conducted a single round of logging and cannot show if the well has changed over time. Recent experience with time-lapse logging of three monitoring wells at a US Department of Energy sponsored CO2 project has shown the full value of similar tools. Time-lapse logging has shown that well integrity changes over time can be identified. It has also shown that the inclusion of and location of monitoring technologies in the well and the choice of construction materials must be carefully considered. Two of the wells were approximately eight years old at the time of study; they were constructed with steel and fiberglass casing sections and had lines on the outside of the casing running to the surface. The third well was 68 years old when it was studied and was originally constructed as a production well. Repeat logs were collected six or eight years after initial logging. Time-lapse logging showed the evolution of the wells. The results identified locations where cement degraded over time and locations that showed little change. The ultrasonic well maps show clearly that the lines used to connect the monitoring technology to the surface are visible and have a local effect on cement isolation. Testing and sampling was conducted along with logging. It provided insight into changes identified in the time-lapse log results. Point permeability testing was used to provide an in-situ point

  5. Effect of liquid gate bias rising time in pH sensors based on Si nanowire ion sensitive field effect transistors

    Science.gov (United States)

    Jang, Jungkyu; Choi, Sungju; Kim, Jungmok; Park, Tae Jung; Park, Byung-Gook; Kim, Dong Myong; Choi, Sung-Jin; Lee, Seung Min; Kim, Dae Hwan; Mo, Hyun-Sun

    2018-02-01

    In this study, we investigate the effect of rising time (TR) of liquid gate bias (VLG) on transient responses in pH sensors based on Si nanowire ion-sensitive field-effect transistors (ISFETs). As TR becomes shorter and pH values decrease, the ISFET current takes a longer time to saturate to the pH-dependent steady-state value. By correlating VLG with the internal gate-to-source voltage of the ISFET, we found that this effect occurs when the drift/diffusion of mobile ions in analytes in response to VLG is delayed. This gives us useful insight on the design of ISFET-based point-of-care circuits and systems, particularly with respect to determining an appropriate rising time for the liquid gate bias.

  6. CMS High Level Trigger Timing Measurements

    International Nuclear Information System (INIS)

    Richardson, Clint

    2015-01-01

    The two-level trigger system employed by CMS consists of the Level 1 (L1) Trigger, which is implemented using custom-built electronics, and the High Level Trigger (HLT), a farm of commercial CPUs running a streamlined version of the offline CMS reconstruction software. The operational L1 output rate of 100 kHz, together with the number of CPUs in the HLT farm, imposes a fundamental constraint on the amount of time available for the HLT to process events. Exceeding this limit impacts the experiment's ability to collect data efficiently. Hence, there is a critical need to characterize the performance of the HLT farm as well as the algorithms run prior to start up in order to ensure optimal data taking. Additional complications arise from the fact that the HLT farm consists of multiple generations of hardware and there can be subtleties in machine performance. We present our methods of measuring the timing performance of the CMS HLT, including the challenges of making such measurements. Results for the performance of various Intel Xeon architectures from 2009-2014 and different data taking scenarios are also presented. (paper)

  7. Improvement of a questionnaire measuring activity limitations in rising and sitting down in patients with lower-extremity disorders living at home

    NARCIS (Netherlands)

    Roorda, LD; Molenaar, IW; Lankhorst, GJ; Bouter, LM

    2005-01-01

    Objective: To improve a self-administered questionnaire that includes 42 dichotomous items and measures activity limitations in rising and sitting down (R&S) in patients with lower-extremity disorders who live at home. Design: Cross-sectional study. Setting: Outpatient clinics of secondary and

  8. Ciguatera incidence in the US Virgin Islands has not increased over a 30-year time period despite rising seawater temperatures.

    Science.gov (United States)

    Radke, Elizabeth G; Grattan, Lynn M; Cook, Robert L; Smith, Tyler B; Anderson, Donald M; Morris, J Glenn

    2013-05-01

    Ciguatera fish poisoning is the most common marine food poisoning worldwide. It has been hypothesized that increasing seawater temperature will result in increasing ciguatera incidence. In St. Thomas, US Virgin Islands, we performed an island-wide telephone survey (N = 807) and a medical record review of diagnosed ciguatera cases at the emergency department of the sole hospital and compared these data with comparable data sources collected in 1980. Annual incidence from both recent data sources remained high (12 per 1,000 among adults in the telephone survey). However, the combined data sources suggest that incidence has declined by 20% or more or remained stable over 30 years, whereas seawater temperatures were increasing. Illness was associated with lower education levels, higher levels of fish consumption, and having previous episodes of ciguatera; population shifts from 1980 to 2010 in these factors could explain an incidence decline of approximately 3 per 1,000, obscuring effects from rising seawater temperature.

  9. SPHINX: a generator based on 1 microsecond current rise time LTD stages. Status and first results for production of soft X-ray radiation

    International Nuclear Information System (INIS)

    Mangeant, Ch.; Roques, B.; Cadiergues, R.

    2005-01-01

    SPHINX is the new name of the facility developed for soft X-ray production. This facility is based on the ECF2 generator which was designed as a 1-3 MJ, 1 μs rise time, 5-10 MA current driver. We present a detailed view of the technology used for the capacitor bank, for the central vacuum part and for the Z-pinch loads [ru

  10. Ultra Fast Timing Measurements at $^{78}$Ni and $^{132}$Sn

    CERN Multimedia

    2002-01-01

    We propose to measure level lifetimes in the exotic nuclei of $^{81}$Ga and $^{80}$Ga in the vicinity of $^{78}$Ni and of $^{135}$Sb and $^{134}$Sb above $^{132}$Sn by the time-delayed technique. These are relatively simple nuclear systems with a few particles and/or holes outside of the doubly-magic core thus can be treated rather precisely within the shell model. The anticipated new structure information on these nuclei, and in particular the lifetime results will put constraints on the model parameters and will serve to verify their predictions. The selected nuclei are some of the most exotic ones just above $^{78}$Ni or $^{132}$Sn, where the transition rates can be studied at present. Of the strongest interest is the nucleus of $^{81}$Ga, which has only 3 valence protons outside of $^{78}$Ni with the lowest proton orbits being $p_{3/2}$ and $f_{5/2}$. The Ml transition between these states, although allowed by the selection rules, should be $\\textit{l}$-forbidden thus very slow. This should give rise to a...

  11. Timing of breast cancer surgery in relation to the menstrual cycle the rise and fall of a hypothesis

    DEFF Research Database (Denmark)

    Kroman, N.

    2008-01-01

    It has been claimed that the timing of surgery in relation to the menstrual cycle can significantly influence the prognosis among premenopausal women with primary breast cancer. The literature on the subject is reviewed. The results are heterogeneous, and the quality of the studies is in general...

  12. Transic time measures in scattering theory

    International Nuclear Information System (INIS)

    MacMillan, L.W.; Osborn, T.A.

    1980-01-01

    This paper studies the time evolution of state vectors that are the solutions of the time-dependent Schroedinger equation, characterized by a Hamiltonian h. We employ trace-theorem methods to prove that the transit time of state vectors through a finite space region, Σ, may be used to construct a family in the energy variable, epsilon, of unique, positive, trace-class operators. The matrix elements of these operators, give the transit time of any vector through Σ, It is proved that the trace of these operators, for a fixed energy epsilon, provide a function which simultaneously gives the sum of all orbital transit times through region Σ and represents the state density of all vectors that have support on Σ and energy epsilon. We use the transit-time operators to recover the usual theory of time delay for single-channel scattering systems. In the process we extend the known results on time delay to include scattering by fixed impurities in a periodic medium

  13. Time versus frequency domain measurements: layered model ...

    African Journals Online (AJOL)

    ... their high frequency content while among TEM data sets with low frequency content, the averaging times for the FEM ellipticity were shorter than the TEM quality. Keywords: ellipticity, frequency domain, frequency electromagnetic method, model parameter, orientation error, time domain, transient electromagnetic method

  14. Superhilac real-time velocity measurements

    International Nuclear Information System (INIS)

    Feinberg, B.; Meaney, D.; Thatcher, R.; Timossi, C.

    1987-03-01

    Phase probes have been placed in several external beam lines at the LBL heavy ion linear accelerator (SuperHILAC) to provide non-destructive velocity measurements independent of the ion being accelerated. The existing system has been improved to provide the following features: a display refresh rate better than twice per second, a sensitive pseudo-correlation technique to pick out the signal from the noise, simultaneous measurements of up to four ion velocities when more than one beam is being accelerated, and a touch-screen operator interface. These improvements allow the system to be used as a routine tuning aid and beam velocity monitor

  15. Study of signal discrimination for timing measurements

    CERN Document Server

    Krepelkova, Marta

    2017-01-01

    The timing detectors of the CMS-TOTEM Precision Proton Spectrometer (CT-PPS) are currently read out using discrete components, separated into three boards; the first board hosts the sensors and the amplifiers, the second one hosts the discriminators and the third is dedicated to the Time to Digital Converter (TDC) and to the interface with the data acquisition system (DAQ). This work proposes a new front-end electronics for the timing detector, with sensors, amplifiers and discriminators integrated on the same board. We simulated an updated version of the amplifier together with a discriminator designed using commercial components. We decided to use an LVDS buffer as a discriminator, because of its cost, availability, speed and lo w power consumption. As a proof of concept, we used the LVDS input of an FPGA to discriminate signals produced by a detector prototype, using a radioactive source.

  16. Chronopotentiometric chloride sensing using transition time measurement

    NARCIS (Netherlands)

    Abbas, Yawar; de Graaf, D.B.; Olthuis, Wouter; van den Berg, Albert

    2013-01-01

    Detection of chloride ions is crucial to accurately access the concrete structure durability[1]. The existing electrochemical method of chloride ions detection in concrete, potentiometry[1], is not suitable for in-situ measurement due to the long term stability issue of conventional reference

  17. [The reasons and background for the rise of college education of Traditional Chinese Medicine (TCM) in modern times].

    Science.gov (United States)

    Yang, Wen-jie; Huang, Ying; Li, Jie

    2009-09-01

    With western learning spreading throughout the orient, the survival and development of TCM was restrained to a large degree due to the medical administrative policy, educational system and diffusion of western medicine at different social levels. Facing this adversity, the TCM sector complied with the changing times and survived through persistent efforts as well as wide and solid popular foundations, striving actively for the legitimacy status of TCM education and establishing several TCM colleges. During the course of running the colleges, the TCM sector was brave in changing ideas and giving and accepting new knowledge, it explored a comprehensive educational syllabus, which not only promoted the development of TCM education in the Republican period of China, but also laid a foundation for TCM education in the new period.

  18. The cost of travel time variability: three measures with properties

    DEFF Research Database (Denmark)

    Engelson, Leonid; Fosgerau, Mogens

    2016-01-01

    This paper explores the relationships between three types of measures of the cost of travel time variability: measures based on scheduling preferences and implicit departure time choice, Bernoulli type measures based on a univariate function of travel time, and mean-dispersion measures. We...

  19. Measurement of Voice Onset Time in Maxillectomy Patients

    OpenAIRE

    Hattori, Mariko; Sumita, Yuka I.; Taniguchi, Hisashi

    2014-01-01

    Objective speech evaluation using acoustic measurement is needed for the proper rehabilitation of maxillectomy patients. For digital evaluation of consonants, measurement of voice onset time is one option. However, voice onset time has not been measured in maxillectomy patients as their consonant sound spectra exhibit unique characteristics that make the measurement of voice onset time challenging. In this study, we established criteria for measuring voice onset time in maxillectomy patients ...

  20. Time focused measurements of roof runoff quality

    International Nuclear Information System (INIS)

    Schriewer, A.; Horn, H.; Helmreich, B.

    2008-01-01

    Runoff properties and their changes during runoff of a 14 year old zinc roof were investigated. Zinc, lead, cadmium, pH value, rain intensity and electric conductivity have been measured for a period of one year. A runoff rate of 3.73 g/m 2 a and a volume weighted mean zinc concentration of 4.9 mg/L were determined. First flush behaviour was observed in 93% of runoff events. Low rain intensities are correlating with higher zinc concentrations in runoff, whereas the duration of antecedent dry periods could not directly be linked with initial zinc concentrations

  1. A two-level model of rise time in quantum cascade laser materials applied to 5 micron, 9 micron and terahertz-range wavelengths

    International Nuclear Information System (INIS)

    Webb, J F; Yong, K S C; Haldar, M K

    2014-01-01

    An equivalent circuit simulation of a two-level rate equation model for quantum cascade laser (QCL) materials is used to study the turn on delay and rise time for three QCLs with 5 micron, 9 micron and terahertz-range wavelengths. In order to do this it is necessary that the model can deal with large signal responses and not be restricted to small signal responses; the model used here is capable of this. The effect of varying some of the characteristic times in the model is also investigated. The comparison of the terahertz wave QCL with the others is particularly important given the increased interest in terahertz sources which have a large range of important applications, such as in medical imaging

  2. Real time measurement of air radioactivity

    International Nuclear Information System (INIS)

    Galeriu, D.; Craciunescu, T.; Teles, S.

    1998-01-01

    A Local Meteorological and Radiological Monitoring System was developed in our institute for several purposes: local monitoring, extending our experience in other location such as Cernavoda NPP and research. This system has meteorological sensors for wind speed and direction, air temperature, solar radiation, relative humidity, rainfall, dose ratemeter (Geiger-Muller counter - TIEX), Alpha-Beta Activity-in-Air Monitor (AB96), Iodine Monitor and Eberline Intelligent Ionization Chamber (FHT 6010). All data are collected by a programmable interface Delta-T Logger that is controlled by a software (ODAS - 'On-line Data Acquisition Software'). ODAS was developed in IFIN-HH. It has the capability to acquire, calculate and transmit real meteorological and radiological data through local network. The developed software controls the interface, the flux of input data through the serial port RS232 and after some processing (system, configuration, input data, connection to the network checking, etc) it creates data files. These files are transmitted on-line to our workstation or in any other place connected to Internet. Data can be collected from the logger at any time during logging. There is no need to stop logging. Data output from the logger can be controlled either from the logger's keypad or from other user terminals. ODAS is operated as follows: - First, the last written file and the date-time of acquired readings are checked. For establishing communication with logger a RS232 level signal must be sent to it. The logger wakes if asleep and sends back RDY signal. Powering the logger may take up to 100 ms to establish a correct RS232 level. Noise on the output lines occurs during this period and communication software may need to take into account such spurious signals. A command must be sent to the logger within 2 s to confirm that the last signal received is real and not spurious. Otherwise, the logger interprets the signal as noise and sleeps. The software sends further

  3. Enzyme reactions and their time resolved measurements

    International Nuclear Information System (INIS)

    Hajdu, Janos

    1990-01-01

    This paper discusses experimental strategies in data collection with the Laue method and summarises recent results using synchrotron radiation. Then, an assessment is made of the progress towards time resolved studies with protein crystals and the problems that remain. The paper consists of three parts which respectively describe some aspects of Laue diffraction, recent examples of structural results from Laue diffraction, and kinetic Laue crystallography. In the first part, characteristics of Laue diffraction is discussed first, focusing on the harmonics problems, spatials problem, wavelength normalization, low resolution hole, data completeness, and uneven coverage of reciprocal space. Then, capture of the symmetry unique reflection set is discussed focusing on the effect of wavelength range on the number of reciprocal lattice points occupying diffracting positions, effect of crystal to film distance and the film area and shape on the number of reflections captured, and effect of crystal symmetry on the number of unique reflections within the number of reflections captured. The second part addresses the determination of the structure of turkey egg white lysozyme, and calcium binding in tomato bushy stunt virus. The third part describes the initiation of reactions in enzyme crystals, picosecond Laue diffraction at high energy storage rings, and detectors. (N.K.)

  4. Determination of Surface Tension of Surfactant Solutions through Capillary Rise Measurements: An Image-Processing Undergraduate Laboratory Experiment

    Science.gov (United States)

    Huck-Iriart, Cristia´n; De-Candia, Ariel; Rodriguez, Javier; Rinaldi, Carlos

    2016-01-01

    In this work, we described an image processing procedure for the measurement of surface tension of the air-liquid interface using isothermal capillary action. The experiment, designed for an undergraduate course, is based on the analysis of a series of solutions with diverse surfactant concentrations at different ionic strengths. The objective of…

  5. Measurement of the Dead-Time in a Multichannel Analyser

    DEFF Research Database (Denmark)

    Mortensen, L.; Olsen, J.

    1973-01-01

    By means of two simple measurements three different dead-times are determined: the normal dead-time, a dead-time coming from the pile-up, and a dead-time due to the finite width of the timing pulses.......By means of two simple measurements three different dead-times are determined: the normal dead-time, a dead-time coming from the pile-up, and a dead-time due to the finite width of the timing pulses....

  6. How Do We Measure Success in Homelessness Services? : Critically Assessing the Rise of the Homelessness Outcomes Star

    OpenAIRE

    Johnson, Guy; Pleace, Nicholas

    2016-01-01

    The Homelessness Outcomes Star (HOS) is probably the most widespread form of outcome measurement employed by homelessness service providers. Developed in the UK, the HOS is now being used by homelessness services in other European countries and Australia, while being promoted internationally as a validated set of key performance indicators. This paper examines the ideological framework that underpins the HOS, as well as the theoretical and methodological approaches that inform its operation. ...

  7. Luminescence rise time in self-activated PbWO{sub 4} and Ce-doped Gd{sub 3}Al{sub 2}Ga{sub 3}O{sub 12} scintillation crystals

    Energy Technology Data Exchange (ETDEWEB)

    Auffray, E. [CERN, Geneva (Switzerland); Augulis, R. [Center for Physical Sciences and Technology, Savanorių av. 231, Vilnius (Lithuania); Borisevich, A. [Research Institute for Nuclear Problems, Bobruiskaya str. 11, Minsk (Belarus); Gulbinas, V. [Center for Physical Sciences and Technology, Savanorių av. 231, Vilnius (Lithuania); Fedorov, A.; Korjik, M. [Research Institute for Nuclear Problems, Bobruiskaya str. 11, Minsk (Belarus); Lucchini, M.T. [CERN, Geneva (Switzerland); Mechinsky, V. [Research Institute for Nuclear Problems, Bobruiskaya str. 11, Minsk (Belarus); Nargelas, S. [Vilnius University, Universiteto str. 3, Vilnius (Lithuania); Songaila, E. [Center for Physical Sciences and Technology, Savanorių av. 231, Vilnius (Lithuania); Tamulaitis, G. [Vilnius University, Universiteto str. 3, Vilnius (Lithuania); Vaitkevičius, A., E-mail: augustas.vaitkevicius@ff.vu.lt [Vilnius University, Universiteto str. 3, Vilnius (Lithuania); Zazubovich, S. [Institute of Physics, University of Tartu, W. Ostwaldi Str. 1, Tartu (Estonia)

    2016-10-15

    The time resolution of scintillation detectors of ionizing radiation is one of the key parameters sought for in the current and future high-energy physics experiments. This study is encouraged by the necessity to find novel detection methods enabling a sub-10-ps time resolution in scintillation detectors and is focused on the exploitation of fast luminescence rise front. Time-resolved photoluminescence (PL) spectroscopy and thermally stimulated luminescence techniques have been used to study two promising scintillators: self-activated lead tungstate (PWO, PbWO{sub 4}) and Ce-doped gadolinium aluminum gallium garnet (GAGG, Gd{sub 3}Al{sub 2}Ga{sub 3}O{sub 12}). A sub-picosecond PL rise time is observed in PWO, while longer processes in the PL response in GAGG:Ce are detected and studied. The mechanisms responsible for the PL rise time in self-activated and doped scintillators are under discussion. - Highlights: • Photoluminescence rise time is studied in two scintillators: PWO and GAGG:Ce. • Sub-picosecond photoluminescence rise time in PWO is observed for the first time. • A multicomponent luminescence rise edge is observed in GAGG:Ce. • The mechanisms behind luminescence kinetics in the crystals are under discussion.

  8. The correlation between the rise of the tumor temperature during the hyperthermia treatment and the tumor blood flow measured by dynamic CT and 15O gas-positron emission tomography

    International Nuclear Information System (INIS)

    Hattori, Hideyuki

    1993-01-01

    This study was designed to determine the correlation between the rise of tumor temperature during hyperthermia treatment and the blood flow of the tumors measured by dynamic CT (DCT) and 15 O gas-positron emission tomography. In this report, we observed 20 patients with malignant tumors which underwent hyperthermia treatment. In each case, the temperature of the tumor was monitored with a photofiber sensor. DCT's and 15 O gas-positron emission tomographies were applied before the hyperthermia treatment. During the DCT, the tumor blood flow of each tumor was estimated by analyzing the time-dependent activity curve after a bolus injection. During the 15 O gas-positron emission tomography, the tumor blood flow was estimated by the C 15 O 2 -steady-state method. The value of the tumor blood flow estimated by DCT were proportional to those calculated by the 15 O gas-positron emission tomography. These values were inversely proportional to the rise of the temperature of the tumors during hyperthermia treatment. Our results imply that DCT as well as the 15 O gas-positron emission tomography can be used for the prediction of the tumor temperature rise during the hyperthermia treatment. (author)

  9. Dead time effects in laser Doppler anemometry measurements

    DEFF Research Database (Denmark)

    Velte, Clara Marika; Buchhave, Preben; George, William K.

    2014-01-01

    frequency range, starting around the cutoff frequency due to the finite size of the MV. Using computer-generated data mimicking the LDA data, these effects have previously been shown to appear due to the effect of dead time, i.e., the finite time during which the system is not able to acquire new...... measurements. These dead times can be traced back to the fact that the burst-mode LDA cannot measure more than one signal burst at a time. Since the dead time is approximately equal to the residence time for a particle traversing a measurement volume, we are dealing with widely varying dead times, which...

  10. The IPERMOB System for Effective Real-Time Road Travel Time Measurement and Prediction

    OpenAIRE

    Martelli, Francesca; Renda, Maria Elena; Santi, Paolo

    2010-01-01

    Accurate, real-time measurement and estimation of road travel time is considered a central problem in the design of advanced Intelligent Transportation Systems. In particular, whether eective, real-time collection of travel time measurements in a urban area is possible is, to the best of our knowledge, still an open problem. In this paper, we introduce the IPERMOB system for efficient, real-time collection of travel time measurements in urban areas through vehicular networks. We demonstrate t...

  11. Picosecond time measurement using ultra fast analog memories

    OpenAIRE

    Breton, D.; Delagnes, E.; Maalmi, J.

    2009-01-01

    International audience; The currently existing electronics dedicated to precise time measurement is mainly based on the use of constant fraction discriminators (CFD) associated with Time to Digital Converters (TDC). The constant fraction technique minimizes the time walk effect (dependency of timing on the pulse amplitude). Several attempts have been made to integrate CFD in multi-channel ASICs. But the time resolution measured on the most advanced one is of the order of 30 ps rms. Two main t...

  12. ISOL yield predictions from holdup-time measurements

    International Nuclear Information System (INIS)

    Spejewski, Eugene H.; Carter, H Kennon; Mervin, Brenden T.; Prettyman, Emily S.; Kronenberg, Andreas; Stracener, Daniel W

    2008-01-01

    A formalism based on a simple model is derived to predict ISOL yields for all isotopes of a given element based on a holdup-time measurement of a single isotope of that element. Model predictions, based on parameters obtained from holdup-time measurements, are compared to independently-measured experimental values

  13. SHORT COMMUNICATION: Time measurement device with four femtosecond stability

    Science.gov (United States)

    Panek, Petr; Prochazka, Ivan; Kodet, Jan

    2010-10-01

    We present the experimental results of extremely precise timing in the sense of time-of-arrival measurements in a local time scale. The timing device designed and constructed in our laboratory is based on a new concept using a surface acoustic wave filter as a time interpolator. Construction of the device is briefly described. The experiments described were focused on evaluating the timing precision and stability. Low-jitter test pulses with a repetition frequency of 763 Hz were generated synchronously to the local time base and their times of arrival were measured. The resulting precision of a single measurement was typically 900 fs RMS, and a timing stability TDEV of 4 fs was achieved for time intervals in the range from 300 s to 2 h. To our knowledge this is the best value reported to date for the stability of a timing device. The experimental results are discussed and possible improvements are proposed.

  14. The measurement of phi 60 mm x 600 mu m silicon PIN detector gamma sensitivity and time respond

    CERN Document Server

    Hu Meng Chun; Ye Wen Ying

    2002-01-01

    phi 60 mm x 600 mu m silicon PIN detector is a large area and high sensitive one which has been developed in near years. The authors have measured their gamma sensitivity and the time response. The experiment and theoretical calculated results in: sup 6 sup 0 Co gamma sensitivity is about 5 fC centre dot cm sup 2 /MeV, the rise time is about 10 ns and the half-high-width time is about 35 ns

  15. Material Classification Using Raw Time-of-Flight Measurements

    KAUST Repository

    Su, Shuochen; Heide, Felix; Swanson, Robin J.; Klein, Jonathan; Callenberg, Clara; Hullin, Matthias; Heidrich, Wolfgang

    2016-01-01

    We propose a material classification method using raw time-of-flight (ToF) measurements. ToF cameras capture the correlation between a reference signal and the temporal response of material to incident illumination. Such measurements encode unique

  16. Influence of Sensor Ingestion Timing on Consistency of Temperature Measures

    National Research Council Canada - National Science Library

    Goodman, Daniel A; Kenefick, Robert W; Cadarette, Bruce S; Cheuvront, Samuel N

    2009-01-01

    ... (ITS) to measure core body temperature have been demonstrated. However, the effect of elapsed time between ITS ingestion and Tint measurement has not been thoroughly studied. Methods: Eight volunteers...

  17. Plant ecosystem responses to rising atmospheric CO2: applying a "two-timing" approach to assess alternative hypotheses for mechanisms of nutrient limitation

    Science.gov (United States)

    Medlyn, B.; Jiang, M.; Zaehle, S.

    2017-12-01

    There is now ample experimental evidence that the response of terrestrial vegetation to rising atmospheric CO2 concentration is modified by soil nutrient availability. How to represent nutrient cycling processes is thus a key consideration for vegetation models. We have previously used model intercomparison to demonstrate that models incorporating different assumptions predict very different responses at Free-Air CO2 Enrichment experiments. Careful examination of model outputs has provided some insight into the reasons for the different model outcomes, but it is difficult to attribute outcomes to specific assumptions. Here we investigate the impact of individual assumptions in a generic plant carbon-nutrient cycling model. The G'DAY (Generic Decomposition And Yield) model is modified to incorporate alternative hypotheses for nutrient cycling. We analyse the impact of these assumptions in the model using a simple analytical approach known as "two-timing". This analysis identifies the quasi-equilibrium behaviour of the model at the time scales of the component pools. The analysis provides a useful mathematical framework for probing model behaviour and identifying the most critical assumptions for experimental study.

  18. Effect of counting system dead time on thyroid uptake measurements

    International Nuclear Information System (INIS)

    Simpkin, D.J.

    1984-01-01

    Equations are derived and the results of numerical calculations shown that illustrate the effect of counting system dead time on measured thyroid uptake of radioiodine. It is predicted that the observed uptake is higher than the true uptake due to system dead time. This is shown for both paralyzing and nonparalyzing dead time. The effect of increasing the administered activity is shown to increase the measured uptake, in a manner predicted by the paralyzable and nonparalyzable dead time models

  19. Measurement of voice onset time in maxillectomy patients.

    Science.gov (United States)

    Hattori, Mariko; Sumita, Yuka I; Taniguchi, Hisashi

    2014-01-01

    Objective speech evaluation using acoustic measurement is needed for the proper rehabilitation of maxillectomy patients. For digital evaluation of consonants, measurement of voice onset time is one option. However, voice onset time has not been measured in maxillectomy patients as their consonant sound spectra exhibit unique characteristics that make the measurement of voice onset time challenging. In this study, we established criteria for measuring voice onset time in maxillectomy patients for objective speech evaluation. We examined voice onset time for /ka/ and /ta/ in 13 maxillectomy patients by calculating the number of valid measurements of voice onset time out of three trials for each syllable. Wilcoxon's signed rank test showed that voice onset time measurements were more successful for /ka/ and /ta/ when a prosthesis was used (Z = -2.232, P = 0.026 and Z = -2.401, P = 0.016, resp.) than when a prosthesis was not used. These results indicate a prosthesis affected voice onset measurement in these patients. Although more research in this area is needed, measurement of voice onset time has the potential to be used to evaluate consonant production in maxillectomy patients wearing a prosthesis.

  20. Measurement of Voice Onset Time in Maxillectomy Patients

    Directory of Open Access Journals (Sweden)

    Mariko Hattori

    2014-01-01

    Full Text Available Objective speech evaluation using acoustic measurement is needed for the proper rehabilitation of maxillectomy patients. For digital evaluation of consonants, measurement of voice onset time is one option. However, voice onset time has not been measured in maxillectomy patients as their consonant sound spectra exhibit unique characteristics that make the measurement of voice onset time challenging. In this study, we established criteria for measuring voice onset time in maxillectomy patients for objective speech evaluation. We examined voice onset time for /ka/ and /ta/ in 13 maxillectomy patients by calculating the number of valid measurements of voice onset time out of three trials for each syllable. Wilcoxon’s signed rank test showed that voice onset time measurements were more successful for /ka/ and /ta/ when a prosthesis was used (Z=−2.232, P=0.026 and Z=−2.401, P=0.016, resp. than when a prosthesis was not used. These results indicate a prosthesis affected voice onset measurement in these patients. Although more research in this area is needed, measurement of voice onset time has the potential to be used to evaluate consonant production in maxillectomy patients wearing a prosthesis.

  1. Optimal Linear Filters. 2. Pulse Time Measurements in the Presence of Noise

    Energy Technology Data Exchange (ETDEWEB)

    Nygaard, K

    1966-09-15

    The problem of calculating the maximum available timing information contained in nuclear pulses in the presence of noise is solved theoretically. Practical experiments show that the theoretical values can be obtained by very simple, but untraditional, means. An output pulse from a practical filter connected to a charge sensitive amplifier with a Ge(Li) detector showed a rise time of 30 ns and a noise level of less than 5 keV. The time jitter measured was inversely proportional to the pulse height and less than 30 ns for 10 keV pulses. With the timing filter shown solid state detectors can be classified somewhere between Nal scintillators and organic scintillators with respect to time resolution.

  2. Optimal Linear Filters. 2. Pulse Time Measurements in the Presence of Noise

    International Nuclear Information System (INIS)

    Nygaard, K.

    1966-09-01

    The problem of calculating the maximum available timing information contained in nuclear pulses in the presence of noise is solved theoretically. Practical experiments show that the theoretical values can be obtained by very simple, but untraditional, means. An output pulse from a practical filter connected to a charge sensitive amplifier with a Ge(Li) detector showed a rise time of 30 ns and a noise level of less than 5 keV. The time jitter measured was inversely proportional to the pulse height and less than 30 ns for 10 keV pulses. With the timing filter shown solid state detectors can be classified somewhere between Nal scintillators and organic scintillators with respect to time resolution

  3. An Energy-Based Similarity Measure for Time Series

    Directory of Open Access Journals (Sweden)

    Pierre Brunagel

    2007-11-01

    Full Text Available A new similarity measure, called SimilB, for time series analysis, based on the cross-ΨB-energy operator (2004, is introduced. ΨB is a nonlinear measure which quantifies the interaction between two time series. Compared to Euclidean distance (ED or the Pearson correlation coefficient (CC, SimilB includes the temporal information and relative changes of the time series using the first and second derivatives of the time series. SimilB is well suited for both nonstationary and stationary time series and particularly those presenting discontinuities. Some new properties of ΨB are presented. Particularly, we show that ΨB as similarity measure is robust to both scale and time shift. SimilB is illustrated with synthetic time series and an artificial dataset and compared to the CC and the ED measures.

  4. Measurement of gas phase characteristics using new monofiber optical probes and real time signal processing

    International Nuclear Information System (INIS)

    Cartellier, A.

    1998-01-01

    Single optical or impedance phase detection probes are able to measure gas velocities provided that their sensitive length L is accurately known. In this paper, it is shown that L can be controlled during the manufacture of optical probes. Beside, for a probe geometry in the form of a cone + a cylinder + a cone, the corresponding rise time / velocity correlation becomes weakly sensitive to uncontrollable parameter such as the angle of impact on the interface. A real time signal processing performing phase detection as well as velocity measurements is described. Since its sensitivity to the operator inputs is less than the reproducibility of measurements, it is a fairly objective tool. Qualifications achieved in air/water flows with various optical probes demonstrate that the void fraction is detected with a relative error less than 10 %. For bubbly flows, the gas flux is accurate within ±10%, but this uncertainty increases when large bubbles are present in the flow. (author)

  5. Plume rise from multiple sources

    International Nuclear Information System (INIS)

    Briggs, G.A.

    1975-01-01

    A simple enhancement factor for plume rise from multiple sources is proposed and tested against plume-rise observations. For bent-over buoyant plumes, this results in the recommendation that multiple-source rise be calculated as [(N + S)/(1 + S)]/sup 1/3/ times the single-source rise, Δh 1 , where N is the number of sources and S = 6 (total width of source configuration/N/sup 1/3/ Δh 1 )/sup 3/2/. For calm conditions a crude but simple method is suggested for predicting the height of plume merger and subsequent behavior which is based on the geometry and velocity variations of a single buoyant plume. Finally, it is suggested that large clusters of buoyant sources might occasionally give rise to concentrated vortices either within the source configuration or just downwind of it

  6. Measurement-theoretic foundations of time discounting in economics

    OpenAIRE

    Conrad Heilmann

    2008-01-01

    In economics, the concept of time discounting introduces weights on future goods to make these less valuable. Yet, both the conceptual motivation for time discounting and its specic functional form remain contested. To address these problems, this paper provides a measurement-theoretic framework of representation for time discounting. The representation theorem characterises time discounting factors by representations of time dierences. This general result can be interpreted with existing the...

  7. A micropixel avalanche phototransistor for time of flight measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sadigov, A., E-mail: saazik@yandex.ru [National Nuclear Research Center, Baku (Azerbaijan); Institute of Radiation Problems, Baku (Azerbaijan); Suleymanov, S. [National Nuclear Research Center, Baku (Azerbaijan); Institute of Radiation Problems, Baku (Azerbaijan); Ahmadov, F. [National Nuclear Research Center, Baku (Azerbaijan); Ahmadov, G. [National Nuclear Research Center, Baku (Azerbaijan); Joint Institute for Nuclear Research, Dubna (Russian Federation); Abdullayev, K. [National Aviation Academy, Baku (Azerbaijan); Akberov, R. [National Nuclear Research Center, Baku (Azerbaijan); Institute of Radiation Problems, Baku (Azerbaijan); Heydarov, N. [National Nuclear Research Center, Baku (Azerbaijan); Madatov, R. [Institute of Radiation Problems, Baku (Azerbaijan); Mukhtarov, R. [National Aviation Academy, Baku (Azerbaijan); Nazarov, M.; Valiyev, R. [National Nuclear Research Center, Baku (Azerbaijan)

    2017-02-11

    This paper presents results of studies of the silicon based new micropixel avalanche phototransistor (MAPT). MAPT is a modification of well-known silicon photomultipliers (SiPMs) and differs since each photosensitive pixel of the MAPT operates in Geiger mode and comprises an individual micro-transistor operating in binary mode. This provides a high amplitude single photoelectron signal with significantly shorter rise time. The obtained results are compared with appropriate parameters of known SiPMs. - Highlights: • A new photo detector – micropixel avalanche phototransistor was developed. • MAPT has a matrix of microtransistors with fast output. • In these modules the duration of the leading edge of the signal from the photodetectors are not worse than 50–100 ps.

  8. Formation time of a small electron polaron in LiNbO3: measurements and interpretation

    International Nuclear Information System (INIS)

    Qiu, Yong; Ucer, K.B.; Williams, R.T.

    2005-01-01

    Infrared optical absorption attributed to the electron polaron on a non-defective site in LiNbO 3 and KNbO 3 has previously been observed using pulsed electron and laser techniques. With subpicosecond laser excitation and spectroscopy, it is possible to measure a rise time of the infrared absorption, which may be interpreted as the time for a band-state conduction electron to cool by phonon scattering, collapse its wavefunction around a site made attractive by thermal disorder, and relax vibrationally to a small polaron. This is a process which is of fundamental interest, involving dynamics of self-localization from band states and vibrational relaxation of a localized electron in an otherwise non-defective lattice. For example, Gavartin and Shluger have recently performed calculations on the role of thermal fluctuations in self-trapping of holes in MgO. We report initial measurements on the rise time of infrared absorption at 0.95 eV (Mg-perturbed polaron) in LiNbO 3 :Mg to be τ R ∼230 fs at T=20 K and τ R ∼110 fs at T=296 K. We discuss 2 stages that together may account for the delay and its temperature dependence: free-electron cooling and vibrational relaxation of a ''defect'' (small polaron) in a host. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  9. Rise of a cold plume

    International Nuclear Information System (INIS)

    Kakuta, Michio

    1977-06-01

    The rise of smoke from the stacks of two research reactors in normal operation was measured by photogrametric method. The temperature of effluent gas is less than 20 0 C higher than that of the ambient air (heat emission of the order 10 4 cal s -1 ), and the efflux velocity divided by the wind speed is between 0.5 and 2.8 in all 16 smoke runs. The field data obtained within downwind distance of 150m are compared with those by plume rise formulas presently available. Considering the shape of bending-over plume, the Briggs' formula for 'jet' gives a reasonable explanation of the observed plume rise. (auth.)

  10. Measuring work-life balance using time diary data

    OpenAIRE

    Kimberly Fisher; Richard Layte

    2004-01-01

    This paper examines how time diaries facilitate the study of work-life balance. We first compare aggregate time spent in paid work, unpaid work, attending to personal needs, and free time across seven countries using the Multinational Time Use Study. We then measure the overlap of work with other activities in two ways. First, we map the timing of episodes of work over the day, and overlay these maps onto maps of leisure time. A social group can be said to have a work-life balance if their pe...

  11. Real-time database for high resolution neutron monitor measurements

    Energy Technology Data Exchange (ETDEWEB)

    Steigies, Christian T.; Rother, Oliver M.; Wimmer-Schweingruber, Robert F.; Heber, Bernd [IEAP, Christian-Albrechts-Universitaet zu Kiel (Germany)

    2008-07-01

    The worldwide network of standardised neutron monitors is, after 50 years, still the state-of-the-art instrumentation to measure spectral variations of the primary cosmic ray component. These measurements are an ideal complement to space based cosmic ray measurements. Data from the approximately 50 IGY and NM64 neutron monitors is stored locally but also available through data collections sites like the World Data Center (WDC) or the IZMIRAN ftp server. The data from the WDC is in a standard format, but only hourly values are available. IZMIRAN collects the data in the best available time resolution, but the data arrives on the ftp server only hours, sometimes days, after the measurements. Also, the high time-resolution measurements of the different stations do not have a common format, a conversion routine for each station is needed before they can be used for scientific analysis. Supported by the 7th framework program of the European Commission, we are setting up a real-time database where high resolution cosmic ray measurements will be stored and accessible immediately after the measurement. Stations that do not have 1-minute resolution measurements will be upgraded to 1-minute or better resolution with an affordable standard registration system, that will submit the measurements to the database via the internet in real-time.

  12. Perceived Time as a Measure of Mental Workload

    DEFF Research Database (Denmark)

    Hertzum, Morten; Holmegaard, Kristin Due

    2013-01-01

    The mental workload imposed by systems is important to their operation and usability. Consequently, researchers and practitioners need reliable, valid, and easy-to-administer methods for measuring mental workload. The ratio of perceived time to clock time appears to be such a method, yet mental...... is a performance-related rather than task-related dimension of mental workload. We find a higher perceived time ratio for timed than untimed tasks. According to subjective workload ratings and pupil-diameter measurements the timed tasks impose higher mental workload. This finding contradicts the prospective...... paradigm, which asserts that perceived time decreases with increasing mental workload. We also find a higher perceived time ratio for solved than unsolved tasks, while subjective workload ratings indicate lower mental workload for the solved tasks. This finding shows that the relationship between...

  13. Real-time personal dose measurement and management system

    International Nuclear Information System (INIS)

    Zhang Zhiyong; Cheng Chang; Liu Zhengshan; Yang Huating; Deng Changming; Zhang Xiu; Guo Zhanjie

    2001-01-01

    The composition and design of a real-time personal dose measurement and management system are described. Accordingly, some pertinent hardware circuits and software codes including their operation modes are presented

  14. Apparatus for Measurements of Time and Space Correlation

    Science.gov (United States)

    Favre, Alexandre; Gaviglio, J; Dumas, R

    1955-01-01

    A brief review is made of improvements to an experimental apparatus for time and space correlation designed for study of turbulence. Included is a description of the control of the measurements and a few particular applications.

  15. Time-resolved beam energy measurements at LAMPF

    International Nuclear Information System (INIS)

    Hudgings, D.W.; Clark, D.A.; Bryant, H.C.

    1979-01-01

    A narrow atomic photodetachment resonance is used to measure the LAMPF beam energy. Energy and time resolution are adequate to permit the use of this method in studying transient changes in accelerated beam energy

  16. Real-time scatter measurement and correction in film radiography

    International Nuclear Information System (INIS)

    Shaw, C.G.

    1987-01-01

    A technique for real-time scatter measurement and correction in scanning film radiography is described. With this technique, collimated x-ray fan beams are used to partially reject scattered radiation. Photodiodes are attached to the aft-collimator for sampled scatter measurement. Such measurement allows the scatter distribution to be reconstructed and subtracted from digitized film image data for accurate transmission measurement. In this presentation the authors discuss the physical and technical considerations of this scatter correction technique. Examples are shown that demonstrate the feasibility of the technique. Improved x-ray transmission measurement and dual-energy subtraction imaging are demonstrated with phantoms

  17. [A new measurement method of time-resolved spectrum].

    Science.gov (United States)

    Shi, Zhi-gang; Huang, Shi-hua; Liang, Chun-jun; Lei, Quan-sheng

    2007-02-01

    A new method for measuring time-resolved spectrum (TRS) is brought forward. Programming with assemble language controlled the micro-control-processor (AT89C51), and a kind of peripheral circuit constituted the drive circuit, which drived the stepping motor to run the monochromator. So the light of different kinds of expected wavelength could be obtained. The optical signal was transformed to electrical signal by optical-to-electrical transform with the help of photomultiplier tube (Hamamatsu 1P28). The electrical signal of spectrum data was transmitted to the oscillograph. Connecting the two serial interfaces of RS232 between the oscillograph and computer, the electrical signal of spectrum data could be transmitted to computer for programming to draw the attenuation curve and time-resolved spectrum (TRS) of the swatch. The method for measuring time-resolved spectrum (TRS) features parallel measurement in time scale but serial measurement in wavelength scale. Time-resolved spectrum (TRS) and integrated emission spectrum of Tb3+ in swatch Tb(o-BBA)3 phen were measured using this method. Compared with the real time-resolved spectrum (TRS). It was validated to be feasible, credible and convenient. The 3D spectra of fluorescence intensity-wavelength-time, and the integrated spectrum of the swatch Tb(o-BBA)3 phen are given.

  18. A RECURSIVE ALGORITHM SUITABLE FOR REAL-TIME MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Giovanni Bucci

    1995-12-01

    Full Text Available This paper deals with a recursive algorithm suitable for realtime measurement applications, based on an indirect technique, useful in those applications where the required quantities cannot be measured in a straightforward way. To cope with time constraints a parallel formulation of it, suitable to be implemented on multiprocessor systems, is presented. The adopted concurrent implementation is based on factorization techniques. Some experimental results related to the application of the system for carrying out measurements on synchronous motors are included.

  19. Investment horizons : A time-dependent measure of asset performance

    OpenAIRE

    Ingve Simonsen; Anders Johansen; Mogens H. Jensen

    2005-01-01

    We review a resent {\\em time-dependent} performance measure for economical time series -- the (optimal) investment horizon approach. For stock indices, the approach shows a pronounced gain-loss asymmetry that is {\\em not} observed for the individual stocks that comprise the index. This difference may hint towards an synchronize of the draw downs of the stocks.

  20. Measuring time and risk preferences: Reliability, stability, domain specificity

    NARCIS (Netherlands)

    Wölbert, E.M.; Riedl, A.M.

    2013-01-01

    To accurately predict behavior economists need reliable measures of individual time preferences and attitudes toward risk and typically need to assume stability of these characteristics over time and across decision domains. We test the reliability of two choice tasks for eliciting discount rates,

  1. Shear velocities in the oceanic crust at the East Pacific Rise 9° 18' N to 10° 30' N from compliance measurements

    Science.gov (United States)

    Nooner, S. L.; Webb, S. C.; Crawford, W. C.

    2007-12-01

    Compliance was measured at 21 sites along the East Pacific Rise (EPR) from 9° 18' N to 10° 30' N during the MADCAP (Melt And Diking from Compliance And Pressure) experiment on the R/V Atlantis from February 13 to March 19, 2007. Measurements at 10° 30' N across the ridge segment 22 km north of the Clipperton transform fault show a stiff lower crust, which suggests that there is little crustal melt. This is consistent with previous descriptions of this segment as "magmatically starved" based on its morphology. Most of the compliance measurements were made on the EPR segment south of the Clipperton transform fault. At the northern end of this ridge segment, a compliance transect at 10° 2' N spans the ridge axis and continues to a seamount 16 km east. These measurements indicate that shear velocities are low beneath the ridge axis but increase rapidly off axis to the east, suggesting no magmatic connection between the ridge axis and the Watchstander seamount chain. Shear velocities beneath the nearest (and most recently active) seamount are similar to other off axis sites, suggesting that there is little or no crustal melt there. A 26 km long compliance transect across the ridge axis near 9° 20' N suggests that the region of low crustal shear velocities is constrained to within 3-4 km of the ridge axis. The compliance measurements preclude the existence of a melt body 18-20 km east of the ridge axis as had been inferred from an apparent mid-crustal reflector observed in a recent OBS experiment. The compliance over that site show low shear velocities only in the uppermost crust associated with a thick layer 2A. A final compliance transect stretches northward along the ridge axis and across the Clipperton ridge-transform intersection (RTI). Measurements made north of where the ridge crosses the inferred location of the RTI show lower crustal shear velocities than normal for off-axis crust, but this observation is consistent with previous refraction work that

  2. Time course of the rise in UV fluorescence intensity following irradiation and experimental conditions for the determination of this parameter in vital Ehrlich-ascitic tumour cells

    International Nuclear Information System (INIS)

    Merkle, K.

    1977-01-01

    The use of the impulse cytophotometric method of measurement in the UV region of the spectrum has allowed to determine the change of primary fluorescence intensity on vital unstained cells without the influence of UV exposure or other factors affecting the measuring result in an uncontrollable way. The studies on the influence of storage time and -temperature have shown that a storage time of up to 25 min at 20 0 C has no effect on the fluorescence intensity of Ehrlich ascites cells. On day 11 after inoculation the fluorescence level is about 20% higher than on day 8, but is much better reproducible at the latter date. After 600 rads gamma irradiation applied on the 6th day, this parameter starts oscillating around normal values and is stabilized within 20 hrs after irradiation; these values remain constant in the next 40 hrs. Even after exposure to 100, 200 and 300 rads gamma radiation a constant UV fluorescence intensity is registered in this time interval. Measurements of this parameter in the phase of relative constancy allow a clear-cut interpretation of the results of further radiobiological investigations. (author)

  3. Accuracy of single photoelectron time spread measurement of fast photomultipliers

    International Nuclear Information System (INIS)

    Leskovar, B.

    1975-01-01

    The accuracy of time spread measurements of fast photomultipliers was investigated, using single photoelectrons. The effect of the finite light pulse width on the measurement accuracy was determined and discussed. Experimental data were obtained on a special measuring system for light pulse widths ranging from 200 psec to 10 nsec, using fast photomultipliers 8850 and C31024 with optimized operating conditions for minimum transit time spread. A modified exponential function expression and curve-fitting parameters are given, which fit closely the experimentally obtained data over a wide dynamic range of light pulse widths. (U.S.)

  4. Subtleties in the BABAR measurement of time-reversal violation

    International Nuclear Information System (INIS)

    Efrati, Aielet

    2015-01-01

    A first measurement of time-reversal (T) asymmetries that are not also CP asymmetries has been recently achieved by the B A B AR collaboration. In this talk, which follows the work done in Ref. [1], I discuss the subtleties of this measurement in the presence of direct CP violation, CPT violation, wrong strangeness decays and wrong sign semi-leptonic decays. In particular, I explain why, in order to identify the measured asymmetries with time-reversal violation, one needs to assume (i) the absence of wrong strangeness decays or of CPT violation in strangeness changing decays, and (ii) the absence of wrong sign decays. (paper)

  5. Stability of continuous-time quantum filters with measurement imperfections

    Science.gov (United States)

    Amini, H.; Pellegrini, C.; Rouchon, P.

    2014-07-01

    The fidelity between the state of a continuously observed quantum system and the state of its associated quantum filter, is shown to be always a submartingale. The observed system is assumed to be governed by a continuous-time Stochastic Master Equation (SME), driven simultaneously by Wiener and Poisson processes and that takes into account incompleteness and errors in measurements. This stability result is the continuous-time counterpart of a similar stability result already established for discrete-time quantum systems and where the measurement imperfections are modelled by a left stochastic matrix.

  6. Timing jitter measurements at the SLC electron source

    International Nuclear Information System (INIS)

    Sodja, J.; Browne, M.J.; Clendenin, J.E.

    1989-03-01

    The SLC thermionic gun and electron source produce a beam of up to 15 /times/ 10 10 /sub e//minus/ in a single S-band bunch. A 170 keV, 2 ns FWHM pulse out of the gun is compressed by means of two subharmonic buncher cavities followed by an S-band buncher and a standard SLAC accelerating section. Ceramic gaps in the beam pipe at the output of the gun allow a measure of the beam intensity and timing. A measurement at these gaps of the timing jitter, with a resolution of <10 ps, is described. 3 refs., 5 figs

  7. A time-to-amplitude converter with constant fraction timing discriminators for short time interval measurements

    International Nuclear Information System (INIS)

    Kostamovaara, J.; Myllylae, R.

    1985-01-01

    The construction and the performance of a time-to-amplitude converter equipped with constant fraction discriminators is described. The TAC consists of digital and analog parts which are constructed on two printed circuit boards, both of which are located in a single width NIM module. The dead time of the TAC for a start pulse which is not followed by a stop pulse within the time range of the device (proportional100 ns) is only proportional100 ns, which enables one to avoid counting rate saturation even with a high random input signal rate. The differential and integral nonlinearities of the TAC are better than +-1.5% and 0.05%, respectively. The resolution for input timing pulses of constant shape is 20 ps (fwhm), and less than 10 ps (fwhm) with a modification in the digital part. The walk error of the constant fraction timing discriminators is presented and various parameters affecting it are discussed. The effect of the various disturbances in linearity caused by the fast ECL logic and their minimization are also discussed. The time-to-amplitude converter has been used in positron lifetime studies and for laser range finding. (orig.)

  8. Decreases in Psychological Well-Being Among American Adolescents After 2012 and Links to Screen Time During the Rise of Smartphone Technology.

    Science.gov (United States)

    Twenge, Jean M; Martin, Gabrielle N; Campbell, W Keith

    2018-01-22

    In nationally representative yearly surveys of United States 8th, 10th, and 12th graders 1991-2016 (N = 1.1 million), psychological well-being (measured by self-esteem, life satisfaction, and happiness) suddenly decreased after 2012. Adolescents who spent more time on electronic communication and screens (e.g., social media, the Internet, texting, gaming) and less time on nonscreen activities (e.g., in-person social interaction, sports/exercise, homework, attending religious services) had lower psychological well-being. Adolescents spending a small amount of time on electronic communication were the happiest. Psychological well-being was lower in years when adolescents spent more time on screens and higher in years when they spent more time on nonscreen activities, with changes in activities generally preceding declines in well-being. Cyclical economic indicators such as unemployment were not significantly correlated with well-being, suggesting that the Great Recession was not the cause of the decrease in psychological well-being, which may instead be at least partially due to the rapid adoption of smartphones and the subsequent shift in adolescents' time use. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  9. Coal prices rise

    International Nuclear Information System (INIS)

    McLean, A.

    2001-01-01

    Coking and semi hard coking coal price agreements had been reached, but, strangely enough, the reaching of common ground on semi soft coking coal, ultra low volatile coal and thermal coal seemed some way off. More of this phenomenon later, but suffice to say that, traditionally, the semi soft and thermal coal prices have fallen into place as soon as the hard, or prime, coking coal prices have been determined. The rise and rise of the popularity of the ultra low volatile coals has seen demand for this type of coal grow almost exponentially. Perhaps one of the most interesting facets of the coking coal settlements announced to date is that the deals appear almost to have been preordained. The extraordinary thing is that the preordination has been at the prescience of the sellers. Traditionally, coking coal price fixing has been the prerogative of the Japanese Steel Mills (JSM) cartel (Nippon, NKK, Kawasaki, Kobe and Sumitomo) who presented a united front to a somewhat disorganised force of predominantly Australian and Canadian sellers. However, by the time JFY 2001 had come round, the rules of the game had changed

  10. Comparison of Travel-Time and Amplitude Measurements for Deep-Focusing Time-Distance Helioseismology

    Science.gov (United States)

    Pourabdian, Majid; Fournier, Damien; Gizon, Laurent

    2018-04-01

    The purpose of deep-focusing time-distance helioseismology is to construct seismic measurements that have a high sensitivity to the physical conditions at a desired target point in the solar interior. With this technique, pairs of points on the solar surface are chosen such that acoustic ray paths intersect at this target (focus) point. Considering acoustic waves in a homogeneous medium, we compare travel-time and amplitude measurements extracted from the deep-focusing cross-covariance functions. Using a single-scattering approximation, we find that the spatial sensitivity of deep-focusing travel times to sound-speed perturbations is zero at the target location and maximum in a surrounding shell. This is unlike the deep-focusing amplitude measurements, which have maximum sensitivity at the target point. We compare the signal-to-noise ratio for travel-time and amplitude measurements for different types of sound-speed perturbations, under the assumption that noise is solely due to the random excitation of the waves. We find that, for highly localized perturbations in sound speed, the signal-to-noise ratio is higher for amplitude measurements than for travel-time measurements. We conclude that amplitude measurements are a useful complement to travel-time measurements in time-distance helioseismology.

  11. ASIC for time-of-flight measurements with picosecond timing resolution

    Energy Technology Data Exchange (ETDEWEB)

    Stankova, Vera; Shen, Wei; Harion, Tobias [Kirchhoff-Institute for Physics, Heidelberg Univ. (Germany)

    2015-07-01

    The Positron Emission Tomography (PET) images are especially affected by a high level of noise. This noise affects the potential to detect and discriminate the tumor in relation to the background. Including Time-of-Flight information, with picosecond time resolution, within the conventional PET scanners will improve the signal-to-noise ratio (SNR) and in sequence the quality of the medical images. A mix-mode ASIC (STIC3) has been developed for high precision timing measurements with Silicon Photomultipliers (SiPM). The STiC3 is 64-channel chip, with fully differential analog front-end for crosstalk and electronic noise immunity. It integrates Time to Digital Converters (TDC) with time binning of 50.2 ps for time and energy measurements. Measurements of the of the analog front-end show a time jitter less than 20 ps and jitter of the TDC together with the digital part is around 37 ps. Further the timing of a channel has been tested by injecting a pulse into two channels and measuring the time difference of the recorded timestamps. A Coincidence Time Resolution (CTR) of 215 ps FWHM has been obtained with 3.1 x 3.1 x 15 mm{sup 2} LYSO:Ce scintillator crystals and Hamamatsu SiPM matric (S12643-050CN(x)). Characterization measurements with the chip and its performances are presented.

  12. Potential barrier classification by short-time measurement

    International Nuclear Information System (INIS)

    Granot, Er'el; Marchewka, Avi

    2006-01-01

    We investigate the short-time dynamics of a delta-function potential barrier on an initially confined wave packet. There are mainly two conclusions: (A) At short times the probability density of the first particles that passed through the barrier is unaffected by it. (B) When the barrier is absorptive (i.e., its potential is imaginary) it affects the transmitted wave function at shorter times than a real potential barrier. Therefore, it is possible to distinguish between an imaginary and a real potential barrier by measuring its effect at short times only on the transmitting wave function

  13. Potential barrier classification by short-time measurement

    Science.gov (United States)

    Granot, Er'El; Marchewka, Avi

    2006-03-01

    We investigate the short-time dynamics of a delta-function potential barrier on an initially confined wave packet. There are mainly two conclusions: (A) At short times the probability density of the first particles that passed through the barrier is unaffected by it. (B) When the barrier is absorptive (i.e., its potential is imaginary) it affects the transmitted wave function at shorter times than a real potential barrier. Therefore, it is possible to distinguish between an imaginary and a real potential barrier by measuring its effect at short times only on the transmitting wave function.

  14. Tunneling Time and Weak Measurement in Strong Field Ionization.

    Science.gov (United States)

    Zimmermann, Tomáš; Mishra, Siddhartha; Doran, Brent R; Gordon, Daniel F; Landsman, Alexandra S

    2016-06-10

    Tunneling delays represent a hotly debated topic, with many conflicting definitions and little consensus on when and if such definitions accurately describe the physical observables. Here, we relate these different definitions to distinct experimental observables in strong field ionization, finding that two definitions, Larmor time and Bohmian time, are compatible with the attoclock observable and the resonance lifetime of a bound state, respectively. Both of these definitions are closely connected to the theory of weak measurement, with Larmor time being the weak measurement value of tunneling time and Bohmian trajectory corresponding to the average particle trajectory, which has been recently reconstructed using weak measurement in a two-slit experiment [S. Kocsis, B. Braverman, S. Ravets, M. J. Stevens, R. P. Mirin, L. K. Shalm, and A. M. Steinberg, Science 332, 1170 (2011)]. We demonstrate a big discrepancy in strong field ionization between the Bohmian and weak measurement values of tunneling time, and we suggest this arises because the tunneling time is calculated for a small probability postselected ensemble of electrons. Our results have important implications for the interpretation of experiments in attosecond science, suggesting that tunneling is unlikely to be an instantaneous process.

  15. Effects of barium concentration on oropharyngeal swallow timing measures.

    Science.gov (United States)

    Stokely, Shauna L; Molfenter, Sonja M; Steele, Catriona M

    2014-02-01

    Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between "thin" (40 % w/v concentration) and "ultrathin" (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; mean age = 31 years) each performed a series of three noncued 5-ml swallows each of ultrathin and thin liquid barium solutions in videofluoroscopy. Timing measures were compared between barium concentrations using a mixed-model ANOVA. The measures of interest were stage transition duration, pharyngeal transit time, and duration of upper esophageal sphincter opening. Significant differences were observed in the timing measures of swallowing with respect to barium concentration. In all cases, longer durations were seen with the higher barium concentration. Barium concentration influences timing parameters in healthy swallowing, even between ultrathin and thin concentrations. Clinicians need to understand and control for the impact of different barium stimuli on swallowing physiology.

  16. Use of Response Time for Measuring Cognitive Ability

    Directory of Open Access Journals (Sweden)

    Patrick C. Kyllonen

    2016-11-01

    Full Text Available The purpose of this paper is to review some of the key literature on response time as it has played a role in cognitive ability measurement, providing a historical perspective as well as covering current research. We discuss the speed-level distinction, dimensions of speed and level in cognitive abilities frameworks, speed–accuracy tradeoff, approaches to addressing speed–accuracy tradeoff, analysis methods, particularly item response theory-based, response time models from cognitive psychology (ex-Gaussian function, and the diffusion model, and other uses of response time in testing besides ability measurement. We discuss several new methods that can be used to provide greater insight into the speed and level aspects of cognitive ability and speed–accuracy tradeoff decisions. These include item-level time limits, the use of feedback (e.g., CUSUMs, explicit scoring rules that combine speed and accuracy information (e.g., count down timing, and cognitive psychology models. We also review some of the key psychometric advances in modeling speed and level, which combine speed and ability measurement, address speed–accuracy tradeoff, allow for distinctions between response times on items responded to correctly and incorrectly, and integrate psychometrics with information-processing modeling. We suggest that the application of these models and tools is likely to advance both the science and measurement of human abilities for theory and applications.

  17. Identifying Time Measurement Tampering in the Traversal Time and Hop Count Analysis (TTHCA Wormhole Detection Algorithm

    Directory of Open Access Journals (Sweden)

    Jonny Karlsson

    2013-05-01

    Full Text Available Traversal time and hop count analysis (TTHCA is a recent wormhole detection algorithm for mobile ad hoc networks (MANET which provides enhanced detection performance against all wormhole attack variants and network types. TTHCA involves each node measuring the processing time of routing packets during the route discovery process and then delivering the measurements to the source node. In a participation mode (PM wormhole where malicious nodes appear in the routing tables as legitimate nodes, the time measurements can potentially be altered so preventing TTHCA from successfully detecting the wormhole. This paper analyses the prevailing conditions for time tampering attacks to succeed for PM wormholes, before introducing an extension to the TTHCA detection algorithm called ∆T Vector which is designed to identify time tampering, while preserving low false positive rates. Simulation results confirm that the ∆T Vector extension is able to effectively detect time tampering attacks, thereby providing an important security enhancement to the TTHCA algorithm.

  18. Time resolved measurements of triton burnup in JET plasmas

    International Nuclear Information System (INIS)

    Conroy, S.; Jarvis, O.N.; Sadler, G.; Huxtable, G.B.

    1988-01-01

    Triton production from one branch of the deuteron-deuteron fusion reaction is routinely measured at 6 ms time intervals in JET plasma discharges by recording the 2.5 MeV neutrons produced in the other branch using a set of calibrated fission chambers. The burnup of the tritons is measured by detecting the 14 MeV t-d neutrons with a 0.2 cm 3 Si(Li) diode. The 2.5 MeV neutron flux can be used in a simple time dependent calculation based on classical slowing-down theory to predict the 14 MeV neutron flux. The measured flux and the triton slowing-down time are systematically lower than the values estimated from the key plasma parameters but the differences are within the experimental errors. (author). 19 refs, 8 figs

  19. New method for measuring time-resolved spectra of lanthanide emission using square-wave excitation

    International Nuclear Information System (INIS)

    Qin, Feng; Zhao, Hua; Cai, Wei; Duan, Qianqian; Zhang, Zhiguo; Cao, Wenwu

    2013-01-01

    A method using modulated continuous wave (CW) visible laser to measure time-resolved fluorescence spectra of trivalent rare-earth ions has been developed. Electro-optic modulator was used to modulate the CW pumping laser with a rise time of 2 μs. CW Nd 3+ lasers were used as examples to present the method. Upconversion dynamic process of Ho 3+ was studied utilizing a 532 nm CW laser. Quantum cutting dynamic process from Tb 3+ to Yb 3+ was analyzed by a 473 nm CW laser. This method can be applied to any CW laser such as He-Ne laser, Ar + laser, Kr + laser, Ti:sapphire laser, etc

  20. Measurement and deconvolution of detector response time for short HPM pulses: Part 1, Microwave diodes

    International Nuclear Information System (INIS)

    Bolton, P.R.

    1987-06-01

    A technique is described for measuring and deconvolving response times of microwave diode detection systems in order to generate corrected input signals typical of an infinite detection rate. The method has been applied to cases of 2.86 GHz ultra-short HPM pulse detection where pulse rise time is comparable to that of the detector; whereas, the duration of a few nanoseconds is significantly longer. Results are specified in terms of the enhancement of equivalent deconvolved input voltages for given observed voltages. The convolution integral imposes the constraint of linear detector response to input power levels. This is physically equivalent to the conservation of integrated pulse energy in the deconvolution process. The applicable dynamic range of a microwave diode is therefore limited to a smaller signal region as determined by its calibration

  1. APD Response Time Measurements for Future TOF-E Systems

    Science.gov (United States)

    Starkey, M. J.; Ogasawara, K.; Dayeh, M. A.; Desai, M. I.

    2017-12-01

    In space physics, the ability to detect ions is crucial to understanding plasma distributions in the solar wind. This usually typically requires the determination of the particle's mass, charge, and total energy. Current ion detection schemes are implemented in three sequential parts; an electrostatic analyzer for energy per charge (E/Q) measurements, a time-of-flight (TOF) for mass per charge (M/Q) measurements, and a solid-state detector (SSD) for total energy (E) measurements. Recent work has suggested the use of avalanche photodiode detectors (APD) for a simultaneous TOF and total energy (TOF-E) measurement system, which would replace traditional SSDs, simplify design, and reduce costs. Although TOF based ion spectrometry typically requires timing resolution of systems.

  2. Time Synchronized Wireless Sensor Network for Vibration Measurement

    Science.gov (United States)

    Uchimura, Yutaka; Nasu, Tadashi; Takahashi, Motoichi

    Network based wireless sensing has become an important area of research and various new applications for remote sensing are expected to emerge. One of the promising applications is structural health monitoring of building or civil engineering structure and it often requires vibration measurement. For the vibration measurement via wireless network, time synchronization is indispensable. In this paper, we introduce a newly developed time synchronized wireless sensor network system. The system employs IEEE 802.11 standard based TSF counter and sends the measured data with the counter value. TSF based synchronization enables consistency on common clock among different wireless nodes. We consider the scale effect on the synchronization accuracy and the effect is evaluated by stochastic analysis and simulation studies. A new wireless sensing system is developed and the hardware and software specifications are shown. The experiments are conducted in a reinforced concrete building and results show good performance enough for vibration measurement purpose.

  3. Real-time diamagnetic flux measurements on ASDEX Upgrade.

    Science.gov (United States)

    Giannone, L; Geiger, B; Bilato, R; Maraschek, M; Odstrčil, T; Fischer, R; Fuchs, J C; McCarthy, P J; Mertens, V; Schuhbeck, K H

    2016-05-01

    Real-time diamagnetic flux measurements are now available on ASDEX Upgrade. In contrast to the majority of diamagnetic flux measurements on other tokamaks, no analog summation of signals is necessary for measuring the change in toroidal flux or for removing contributions arising from unwanted coupling to the plasma and poloidal field coil currents. To achieve the highest possible sensitivity, the diamagnetic measurement and compensation coil integrators are triggered shortly before plasma initiation when the toroidal field coil current is close to its maximum. In this way, the integration time can be chosen to measure only the small changes in flux due to the presence of plasma. Two identical plasma discharges with positive and negative magnetic field have shown that the alignment error with respect to the plasma current is negligible. The measured diamagnetic flux is compared to that predicted by TRANSP simulations. The poloidal beta inferred from the diamagnetic flux measurement is compared to the values calculated from magnetic equilibrium reconstruction codes. The diamagnetic flux measurement and TRANSP simulation can be used together to estimate the coupled power in discharges with dominant ion cyclotron resonance heating.

  4. Determination of time delay between ventricles contraction using impedance measurements

    International Nuclear Information System (INIS)

    Lewandowska, M; Poliński, A; Wtorek, J

    2013-01-01

    The paper presents a novel approach to assessment of ventricular dyssynchrony basing on multichannel electrical impedance measurements. Using a proper placement of electrodes, the sensitivity approach allows estimating time difference between chambers contraction from over determined nonlinear system of equations. The theoretical considerations which include Finite Element Method simulations were verified using measurements on healthy 28 year's old woman. The nonlinear least squares method was applied to obtain a time difference between heart chambers contraction. The obtained value was in a good agreement with theoretical values found in literature.

  5. Real-Time 3D Profile Measurement Using Structured Light

    International Nuclear Information System (INIS)

    Xu, L; Zhang, Z J; Ma, H; Yu, Y J

    2006-01-01

    The paper builds a real-time system of 3D profile measurement using structured-light imaging. It allows a hand-held object to rotate free in the space-time coded light field, which is projected by the projector. The surface of measured objects with projected coded light is imaged; the system shows surface reconstruction results of objects online. This feedback helps user to adjust object's pose in the light field according to the dismissed or error data, which would achieve the integrality of data used in reconstruction. This method can acquire denser data cloud and have higher reconstruction accuracy and efficiency. According to the real-time requirements, the paper presents the non-restricted light plane modelling which suits stripe structured light system, designs the three-frame stripes space-time coded pattern, and uses the advance ICP algorithms to acquire 3D data alignment from multiple view

  6. Observers' measurements in premetric electrodynamics: Time and radar length

    Science.gov (United States)

    Gürlebeck, Norman; Pfeifer, Christian

    2018-04-01

    The description of an observer's measurement in general relativity and the standard model of particle physics is closely related to the spacetime metric. In order to understand and interpret measurements, which test the metric structure of the spacetime, like the classical Michelson-Morley, Ives-Stilwell, Kennedy-Thorndike experiments or frequency comparison experiments in general, it is necessary to describe them in theories, which go beyond the Lorentzian metric structure. However, this requires a description of an observer's measurement without relying on a metric. We provide such a description of an observer's measurement of the fundamental quantities time and length derived from a premetric perturbation of Maxwell's electrodynamics and a discussion on how these measurements influence classical relativistic observables like time dilation and length contraction. Most importantly, we find that the modification of electrodynamics influences the measurements at two instances: the propagation of light is altered as well as the observer's proper time normalization. When interpreting the results of a specific experiment, both effects cannot be disentangled, in general, and have to be taken into account.

  7. Implementing unsteady friction in pressure-time measurements

    OpenAIRE

    Jonsson, Pontus; Ramdal, Jorgen; Cervantes, Michel; Nielsen, Torbjørn Kristian

    2012-01-01

    Laboratory measurements using the pressure‐time method showed a velocity or Reynolds number dependent error of the flow estimate. It was suspected that the quasi steady friction formulation of the method was the cause. This was investigated, and it was proved that implementing a model for unsteady friction into the calculations improved the result. This paper presents the process of this investigation, and proposes a new method for treatment of the friction term in the pressure‐time method.

  8. Effects of Barium Concentration on Oropharyngeal Swallow Timing Measures

    OpenAIRE

    Stokely, Shauna L.; Molfenter, Sonja M.; Steele, Catriona M.

    2013-01-01

    Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between “thin” (40 % w/v concentration) and “ultrathin” (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; ...

  9. A Method for Measuring Fast Time Evolutions of the Plasma Potential by Means of a Simple Emissive Probe

    DEFF Research Database (Denmark)

    Iizuka, S.; Michelsen, Poul; Juul Rasmussen, Jens

    1981-01-01

    potential is measured across a high resistance. During each sweep of the probe voltage, the changing of the sign of the probe current, which is sampled at a specific time, gives rise to a negative pulse, driving the pen-lift of an X-Y recorder. Since the real floating potential is measured where the probe......A method is presented for obtaining the temporal evolution of the plasma potential, which is assumed to be given by the floating potential of a simple emissive probe. The construction of the probe is also described. The method avoids the slow time response of the usual technique where the floating...

  10. Technological change and the timing of mitigation measures

    International Nuclear Information System (INIS)

    Gruebler, A.; Messner, S.

    1998-01-01

    We use a coupled carbon-cycle and energy systems engineering model to analyze the future time path of carbon emissions under an illustrative CO 2 concentration stabilization limit of 550 ppm. Our findings confirm the emission pattern as found by WRE: global emissions rise initially, pass through stabilization, in order to decline in the second half of the 21st century. We show that for a given CO 2 concentration target, emission trajectories within an intertemporal optimization framework depend mainly on two factors: the discount rate, and the representation of technological change as either static or dynamic. We obtain a similar near-term emission time path as WRE when using a model with static technology and a discount rate of 7%. We obtain a trajectory with lower emissions in the near-term when using a lower discount rate and/or treating technology dynamics endogenously in the model. We briefly outline a model that endogenizes technological change through learning curves. We then compare differences in emission trajectories between alternative model formulations of technological change. They are sufficiently small as to be of secondary importance when compared to treating CO 2 concentration stabilization as an inter-temporal optimization problem or not. Whereas our results confirm the computational results of WRE, we arrive nonetheless at different policy conclusions. If long-term emission reduction is the goal, we cannot follow 'business as usual' even in the short-term. Action needs to start now. Action does not necessarily mean aggressive short-term emission reductions but rather enhanced R and D and technology demonstration efforts that stimulate technological learning. These are the necessary preconditions that long-term reduction targets can be met with improved technology and at costs lower than today. We close by pointing out two further critical issues: uncertainty, and the possible mismatch between the world of economic models and that of climate

  11. FREQUENCY-DEPENDENT DISPERSION MEASURES AND IMPLICATIONS FOR PULSAR TIMING

    Energy Technology Data Exchange (ETDEWEB)

    Cordes, J. M. [Astronomy Department, Cornell University, Ithaca, NY 14853 (United States); Shannon, R. M. [CSIRO Astronomy and Space Science, Box 76, Epping, NSW 1710 (Australia); Stinebring, D. R., E-mail: cordes@astro.cornell.edu, E-mail: ryan.shannon@csiro.au, E-mail: dan.stinebring@oberlin.edu [Department of Physics and Astronomy, Oberlin College, Oberlin, OH 44074 (United States)

    2016-01-20

    The dispersion measure (DM), the column density of free electrons to a pulsar, is shown to be frequency dependent because of multipath scattering from small-scale electron-density fluctuations. DMs vary between propagation paths whose transverse extent varies strongly with frequency, yielding arrival times that deviate from the high-frequency scaling expected for a cold, uniform, unmagnetized plasma (1/frequency{sup 2}). Scaling laws for thin phase screens are verified with simulations; extended media are also analyzed. The rms DM difference across an octave band near 1.5 GHz is ∼ 4 × 10{sup −5} pc cm{sup −3} for pulsars at ∼1 kpc distance. The corresponding arrival-time variations are a few to hundreds of nanoseconds for DM ≲ 30 pc cm{sup −3} but increase rapidly to microseconds or more for larger DMs and wider frequency ranges. Chromatic DMs introduce correlated noise into timing residuals with a power spectrum of “low pass” form. The correlation time is roughly the geometric mean of the refraction times for the highest and lowest radio frequencies used, ranging from days to years, depending on the pulsar. We discuss implications for methodologies that use large frequency separations or wide bandwidth receivers for timing measurements. Chromatic DMs are partially mitigable by including an additional chromatic term in arrival time models. Without mitigation, an additional term in the noise model for pulsar timing is implied. In combination with measurement errors from radiometer noise, an arbitrarily large increase in total frequency range (or bandwidth) will yield diminishing benefits and may be detrimental to overall timing precision.

  12. Frequency-dependent Dispersion Measures and Implications for Pulsar Timing

    Science.gov (United States)

    Cordes, J. M.; Shannon, R. M.; Stinebring, D. R.

    2016-01-01

    The dispersion measure (DM), the column density of free electrons to a pulsar, is shown to be frequency dependent because of multipath scattering from small-scale electron-density fluctuations. DMs vary between propagation paths whose transverse extent varies strongly with frequency, yielding arrival times that deviate from the high-frequency scaling expected for a cold, uniform, unmagnetized plasma (1/frequency2). Scaling laws for thin phase screens are verified with simulations; extended media are also analyzed. The rms DM difference across an octave band near 1.5 GHz is ˜ 4 × 10-5 pc cm-3 for pulsars at ˜1 kpc distance. The corresponding arrival-time variations are a few to hundreds of nanoseconds for DM ≲ 30 pc cm-3 but increase rapidly to microseconds or more for larger DMs and wider frequency ranges. Chromatic DMs introduce correlated noise into timing residuals with a power spectrum of “low pass” form. The correlation time is roughly the geometric mean of the refraction times for the highest and lowest radio frequencies used, ranging from days to years, depending on the pulsar. We discuss implications for methodologies that use large frequency separations or wide bandwidth receivers for timing measurements. Chromatic DMs are partially mitigable by including an additional chromatic term in arrival time models. Without mitigation, an additional term in the noise model for pulsar timing is implied. In combination with measurement errors from radiometer noise, an arbitrarily large increase in total frequency range (or bandwidth) will yield diminishing benefits and may be detrimental to overall timing precision.

  13. Measurement of time delay for a prospectively gated CT simulator.

    Science.gov (United States)

    Goharian, M; Khan, R F H

    2010-04-01

    For the management of mobile tumors, respiratory gating is the ideal option, both during imaging and during therapy. The major advantage of respiratory gating during imaging is that it is possible to create a single artifact-free CT data-set during a selected phase of the patient's breathing cycle. The purpose of the present work is to present a simple technique to measure the time delay during acquisition of a prospectively gated CT. The time delay of a Philips Brilliance BigBore (Philips Medical Systems, Madison, WI) scanner attached to a Varian Real-Time Position Management (RPM) system (Varian Medical Systems, Palo Alto, CA) was measured. Two methods were used to measure the CT time delay: using a motion phantom and using a recorded data file from the RPM system. In the first technique, a rotating wheel phantom was altered by placing two plastic balls on its axis and rim, respectively. For a desired gate, the relative positions of the balls were measured from the acquired CT data and converted into corresponding phases. Phase difference was calculated between the measured phases and the desired phases. Using period of motion, the phase difference was converted into time delay. The Varian RPM system provides an external breathing signal; it also records transistor-transistor logic (TTL) 'X-Ray ON' status signal from the CT scanner in a text file. The TTL 'X-Ray ON' indicates the start of CT image acquisition. Thus, knowledge of the start time of CT acquisition, combined with the real-time phase and amplitude data from the external respiratory signal, provides time-stamping of all images in an axial CT scan. The TTL signal with time-stamp was used to calculate when (during the breathing cycle) a slice was recorded. Using the two approaches, the time delay between the prospective gating signal and CT simulator has been determined to be 367 +/- 40 ms. The delay requires corrections both at image acquisition and while setting gates for the treatment delivery

  14. Measurement of time delay for a prospectively gated CT simulator

    Directory of Open Access Journals (Sweden)

    Goharian M

    2010-01-01

    Full Text Available For the management of mobile tumors, respiratory gating is the ideal option, both during imaging and during therapy. The major advantage of respiratory gating during imaging is that it is possible to create a single artifact-free CT data-set during a selected phase of the patient′s breathing cycle. The purpose of the present work is to present a simple technique to measure the time delay during acquisition of a prospectively gated CT. The time delay of a Philips Brilliance BigBore™ (Philips Medical Systems, Madison, WI scanner attached to a Varian Real-Time Position Management™ (RPM system (Varian Medical Systems, Palo Alto, CA was measured. Two methods were used to measure the CT time delay: using a motion phantom and using a recorded data file from the RPM system. In the first technique, a rotating wheel phantom was altered by placing two plastic balls on its axis and rim, respectively. For a desired gate, the relative positions of the balls were measured from the acquired CT data and converted into corresponding phases. Phase difference was calculated between the measured phases and the desired phases. Using period of motion, the phase difference was converted into time delay. The Varian RPM system provides an external breathing signal; it also records transistor-transistor logic (TTL ′X-Ray ON′ status signal from the CT scanner in a text file. The TTL ′X-Ray ON′ indicates the start of CT image acquisition. Thus, knowledge of the start time of CT acquisition, combined with the real-time phase and amplitude data from the external respiratory signal, provides time-stamping of all images in an axial CT scan. The TTL signal with time-stamp was used to calculate when (during the breathing cycle a slice was recorded. Using the two approaches, the time delay between the prospective gating signal and CT simulator has been determined to be 367 ± 40 ms. The delay requires corrections both at image acquisition and while setting gates for

  15. Measurement of time delay for a prospectively gated CT simulator

    International Nuclear Information System (INIS)

    Goharian, M.; Khan, R.F.H.

    2010-01-01

    For the management of mobile tumors, respiratory gating is the ideal option, both during imaging and during therapy. The major advantage of respiratory gating during imaging is that it is possible to create a single artifact-free CT data-set during a selected phase of the patient's breathing cycle. The purpose of the present work is to present a simple technique to measure the time delay during acquisition of a prospectively gated CT. The time delay of a Philips Brilliance BigBore (Philips Medical Systems, Madison, WI) scanner attached to a Varian Real-Time Position Management (RPM) system (Varian Medical Systems, Palo Alto, CA) was measured. Two methods were used to measure the CT time delay: using a motion phantom and using a recorded data file from the RPM system. In the first technique, a rotating wheel phantom was altered by placing two plastic balls on its axis and rim, respectively. For a desired gate, the relative positions of the balls were measured from the acquired CT data and converted into corresponding phases. Phase difference was calculated between the measured phases and the desired phases. Using period of motion, the phase difference was converted into time delay. The Varian RPM system provides an external breathing signal; it also records transistor-transistor logic (TTL) 'X-Ray ON' status signal from the CT scanner in a text file. The TTL 'X-Ray ON' indicates the start of CT image acquisition. Thus, knowledge of the start time of CT acquisition, combined with the real-time phase and amplitude data from the external respiratory signal, provides time-stamping of all images in an axial CT scan. The TTL signal with time-stamp was used to calculate when (during the breathing cycle) a slice was recorded. Using the two approaches, the time delay between the prospective gating signal and CT simulator has been determined to be 367 ± 40 ms. The delay requires corrections both at image acquisition and while setting gates for the treatment delivery

  16. Part-time work as a pre-retirement measure

    CERN Document Server

    HR Department

    2006-01-01

    Following discussion at the Standing Concertation Committee at its meeting on 7 December 2006, the Director-General has approved the extension of the Part-time work scheme as a pre-retirement measure for the year 2007, i.e. until 31 December 2007. Human Resources Department Tel. 72808/74128

  17. Part-time work as a pre-retirement measure

    CERN Multimedia

    HR Department

    2007-01-01

    Following discussion at the Standing Concertation Committee at its meeting on 2 November 2007, the Director-General has approved the extension of the part-time work scheme as a pre-retirement measure for the year 2008, i.e. until 31 December 2008. Human Resources Department Tel. 74484/73903

  18. Prospects for direct measurement of time-integrated Bs mixing

    International Nuclear Information System (INIS)

    Siccama, I.

    1994-01-01

    This note investigates the prospects of measuring time-integrated B s mixing. Three inclusive decay modes of the B s meson are discussed. For each reconstruction mode, the expected number of events and the different background channels are discussed. Estimates are given for the uncertainty on the mixing parameter χ s . (orig.)

  19. A real-time BWR stability measurement system

    International Nuclear Information System (INIS)

    March-Leuba, J.; King, W.T.

    1988-01-01

    This paper describes the characteristics of a portable, real-time system used for nonperturbational measurements of stability in boiling water reactors. The algorithm used in this system estimates the closed-loop asymptotic decay ratio using only the naturally occurring neutron noise and it is based on the univariate autoregressive methodology. (author)

  20. The effect of tobacco control measures during a period of rising cardiovascular disease risk in India: a mathematical model of myocardial infarction and stroke.

    Directory of Open Access Journals (Sweden)

    Sanjay Basu

    improvements.Smoke-free laws and substantially increased tobacco taxation appear to be markedly potent population measures to avert future cardiovascular deaths in India. Despite the rise in co-morbid cardiovascular disease risk factors like hyperlipidemia and hypertension in low- and middle-income countries, tobacco control is likely to remain a highly effective strategy to reduce cardiovascular deaths.

  1. The effect of tobacco control measures during a period of rising cardiovascular disease risk in India: a mathematical model of myocardial infarction and stroke.

    Science.gov (United States)

    Basu, Sanjay; Glantz, Stanton; Bitton, Asaf; Millett, Christopher

    2013-01-01

    -free laws and substantially increased tobacco taxation appear to be markedly potent population measures to avert future cardiovascular deaths in India. Despite the rise in co-morbid cardiovascular disease risk factors like hyperlipidemia and hypertension in low- and middle-income countries, tobacco control is likely to remain a highly effective strategy to reduce cardiovascular deaths.

  2. Plume rise predictions

    International Nuclear Information System (INIS)

    Briggs, G.A.

    1976-01-01

    Anyone involved with diffusion calculations becomes well aware of the strong dependence of maximum ground concentrations on the effective stack height, h/sub e/. For most conditions chi/sub max/ is approximately proportional to h/sub e/ -2 , as has been recognized at least since 1936 (Bosanquet and Pearson). Making allowance for the gradual decrease in the ratio of vertical to lateral diffusion at increasing heights, the exponent is slightly larger, say chi/sub max/ approximately h/sub e/ - 2 . 3 . In inversion breakup fumigation, the exponent is somewhat smaller; very crudely, chi/sub max/ approximately h/sub e/ -1 . 5 . In any case, for an elevated emission the dependence of chi/sub max/ on h/sub e/ is substantial. It is postulated that a really clever ignorant theoretician can disguise his ignorance with dimensionless constants. For most sources the effective stack height is considerably larger than the actual source height, h/sub s/. For instance, for power plants with no downwash problems, h/sub e/ is more than twice h/sub s/ whenever the wind is less than 10 m/sec, which is most of the time. This is unfortunate for anyone who has to predict ground concentrations, for he is likely to have to calculate the plume rise, Δh. Especially when using h/sub e/ = h/sub s/ + Δh instead of h/sub s/ may reduce chi/sub max/ by a factor of anywhere from 4 to infinity. Factors to be considered in making plume rise predictions are discussed

  3. Use of a large time-compensated scintillation detector in neutron time-of-flight measurements

    International Nuclear Information System (INIS)

    Goodman, C.D.

    1979-01-01

    A scintillator for neutron time-of-flight measurements is positioned at a desired angle with respect to the neutron beam, and as a function of the energy thereof, such that the sum of the transit times of the neutrons and photons in the scintillator are substantially independent of the points of scintillations within the scintillator. Extrapolated zero timing is employed rather than the usual constant fraction timing. As a result, a substantially larger scintillator can be employed that substantially increases the data rate and shortens the experiment time. 3 claims

  4. Measuring Time in Sporting Competitions with the Domain-Specific Language EasyTime

    OpenAIRE

    Fister Jr., Iztok; Fister, Iztok

    2012-01-01

    Measuring time in mass sporting competitions is unthinkable manually today because of their long duration and unreliability. Besides, automatic timing devices based on the RFID technology have become cheaper. However, these devices cannot operate stand-alone. To work efficiently, they need a computer timing system for monitoring results. Such system should be capable of processing the incoming events, encoding and assigning results to a individual competitor, sorting results according to the ...

  5. Understanding Coastal Wetland Vulnerability to Sea-Level Rise Enhanced Inundation Using Real-Time Stage Monitoring, LiDAR, and Monte Carlo Simulation in Everglades National Park

    Science.gov (United States)

    Cooper, H.; Zhang, C.

    2017-12-01

    Coastal wetlands are one of the most productive ecological systems in the world, providing critical habitat area and valuable ecosystem services such as carbon sequestration. However, due to their location in low lying areas, coastal wetlands are particularly vulnerable to sea-level rise (SLR). Everglades National Park (ENP) encompasses the southern-most portion of the Greater Everglades Ecosystem, and is the largest subtropical wetland in the USA. Water depths have shown to have a significant relationship to vegetation community composition and organization while also playing a crucial role in vegetation health throughout the Everglades. Live plants play a vital role in maintaining soil structure (i.e. elevation), and decreases in vegetation health can cause peat collapse or wetland loss resulting in dramatic habitat, organic soil, and elevation loss posing concerns for Everglades management and restoration. One suspected mechanism for peat collapse is enhanced inundation due to SLR, thus mapping and modeling water depths is a critical component to understanding the potential impacts of future SLR. Previous research in the Everglades focused on a conventional Water Depth Model (WDM) approach where a Digital Elevation Model (DEM) is subtracted from a Water Table Elevation Model (WTEM). In this study, the conventional WDM approach is extended to a more rigorous WDM technique so that the accuracy and precision of the underlying data may be considered. Monte Carlo simulation is used to propagate probability distributions through our SLR depth model using our Random Forest-based LiDAR DEM, Empirical Bayesian Kriging-based WTEMs, uncertainties in vertical datums, soil accretion projections, and regional sea-level rise projections. Water depth maps were produced for the wet and dry seasons in April and October, which successfully revealed the potential spatial and temporal water depth variations due to future SLR. It is concluded that a more rigorous WDM technique helps

  6. Measuring older adults' sedentary time: reliability, validity, and responsiveness.

    Science.gov (United States)

    Gardiner, Paul A; Clark, Bronwyn K; Healy, Genevieve N; Eakin, Elizabeth G; Winkler, Elisabeth A H; Owen, Neville

    2011-11-01

    With evidence that prolonged sitting has deleterious health consequences, decreasing sedentary time is a potentially important preventive health target. High-quality measures, particularly for use with older adults, who are the most sedentary population group, are needed to evaluate the effect of sedentary behavior interventions. We examined the reliability, validity, and responsiveness to change of a self-report sedentary behavior questionnaire that assessed time spent in behaviors common among older adults: watching television, computer use, reading, socializing, transport and hobbies, and a summary measure (total sedentary time). In the context of a sedentary behavior intervention, nonworking older adults (n = 48, age = 73 ± 8 yr (mean ± SD)) completed the questionnaire on three occasions during a 2-wk period (7 d between administrations) and wore an accelerometer (ActiGraph model GT1M) for two periods of 6 d. Test-retest reliability (for the individual items and the summary measure) and validity (self-reported total sedentary time compared with accelerometer-derived sedentary time) were assessed during the 1-wk preintervention period, using Spearman (ρ) correlations and 95% confidence intervals (CI). Responsiveness to change after the intervention was assessed using the responsiveness statistic (RS). Test-retest reliability was excellent for television viewing time (ρ (95% CI) = 0.78 (0.63-0.89)), computer use (ρ (95% CI) = 0.90 (0.83-0.94)), and reading (ρ (95% CI) = 0.77 (0.62-0.86)); acceptable for hobbies (ρ (95% CI) = 0.61 (0.39-0.76)); and poor for socializing and transport (ρ < 0.45). Total sedentary time had acceptable test-retest reliability (ρ (95% CI) = 0.52 (0.27-0.70)) and validity (ρ (95% CI) = 0.30 (0.02-0.54)). Self-report total sedentary time was similarly responsive to change (RS = 0.47) as accelerometer-derived sedentary time (RS = 0.39). The summary measure of total sedentary time has good repeatability and modest validity and is

  7. Incorporation of Time Delayed Measurements in a Discrete-time Kalman Filter

    DEFF Research Database (Denmark)

    Larsen, Thomas Dall; Andersen, Nils Axel; Ravn, Ole

    1998-01-01

    In many practical systems there is a delay in some of the sensor devices, for instance vision measurements that may have a long processing time. How to fuse these measurements in a Kalman filter is not a trivial problem if the computational delay is critical. Depending on how much time...... using past and present estimates of the Kalman filter and calculating an optimal gain for this extrapolated measurement...... there is at hand, the designer has to make trade offs between optimality and computational burden of the filter. In this paper various methods in the literature along with a new method proposed by the authors will be presented and compared. The new method is based on “extrapolating” the measurement to present time...

  8. Measuring the electron bunch timing with femtosecond resolution at FLASH

    International Nuclear Information System (INIS)

    Bock, Marie Kristin

    2013-03-01

    Bunch arrival time monitors (BAMs) are an integral part of the laser-based synchronisation system which is being developed at the Free Electron Laser in Hamburg (FLASH).The operation principle comprises the measurement of the electron bunch arrival time relative to the optical timing reference, which is provided by actively length-stabilised fibre-links of the synchronisation system. The monitors are foreseen to be used as a standard diagnostic tool, not only for FLASH but also for the future European X-Ray Free-Electron Laser (European XFEL). The present bunch arrival time monitors have evolved from proof-of-principle experiments to beneficial diagnostic devices, which are almost permanently available during standard machine operation. This achievement has been a major objective of this thesis. The developments went in parallel to improvements in the reliable and low-maintenance operation of the optical synchronisation system. The key topics of this thesis comprised the characterisation and optimisation of the opto-mechanical front-ends of both, the fibre-links and the BAMs. The extent of applications involving the bunch arrival time information has been enlarged, providing automated measurements for properties of the RF acceleration modules, for instance, the RF on-crest phase determination and the measurement of energy fluctuations. Furthermore, two of the currently installed BAMs are implemented in an active phase and gradient stabilisation of specific modules in order to minimise the arrival time jitter of the electron bunches at the location of the FEL undulators, which is crucial for a high timing resolution of pump-probe experiments.

  9. Measuring the electron bunch timing with femtosecond resolution at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Bock, Marie Kristin

    2013-03-15

    Bunch arrival time monitors (BAMs) are an integral part of the laser-based synchronisation system which is being developed at the Free Electron Laser in Hamburg (FLASH).The operation principle comprises the measurement of the electron bunch arrival time relative to the optical timing reference, which is provided by actively length-stabilised fibre-links of the synchronisation system. The monitors are foreseen to be used as a standard diagnostic tool, not only for FLASH but also for the future European X-Ray Free-Electron Laser (European XFEL). The present bunch arrival time monitors have evolved from proof-of-principle experiments to beneficial diagnostic devices, which are almost permanently available during standard machine operation. This achievement has been a major objective of this thesis. The developments went in parallel to improvements in the reliable and low-maintenance operation of the optical synchronisation system. The key topics of this thesis comprised the characterisation and optimisation of the opto-mechanical front-ends of both, the fibre-links and the BAMs. The extent of applications involving the bunch arrival time information has been enlarged, providing automated measurements for properties of the RF acceleration modules, for instance, the RF on-crest phase determination and the measurement of energy fluctuations. Furthermore, two of the currently installed BAMs are implemented in an active phase and gradient stabilisation of specific modules in order to minimise the arrival time jitter of the electron bunches at the location of the FEL undulators, which is crucial for a high timing resolution of pump-probe experiments.

  10. Time interval measurement between to emission: a systematics

    International Nuclear Information System (INIS)

    Bizard, G.; Bougault, R.; Brou, R.; Colin, J.; Durand, D.; Genoux-Lubain, A.; Horn, D.; Kerambrun, A.; Laville, J.L.; Le Brun, C.; Lecolley, J.F.; Lopez, O.; Louvel, M.; Mahi, M.; Meslin, C.; Steckmeyer, J.C.; Tamain, B.; Wieloch, A.

    1998-01-01

    A systematic study of the evolution of intervals of fragment emission times as a function of the energy deposited in the compound system was performed. Several measurements, Ne at 60 MeV/u, Ar at 30 and 60 MeV/u and two measurements for Kr at 60 MeV/u (central and semi-peripheral collisions) are presented. In all the experiments the target was Au and the mass of the compounds system was around A = 200. The excitation energies per nucleon reached in the case of these heavy systems cover the range of 3 to 5.5 MeV/u. The method used to determine the emission time intervals is based on the correlation functions associated to the relative angle distributions. The gaps between the data and simulations allow to evaluate the emission times. A rapid decrease of these time intervals was observed when the excitation energy increased. This variation starts at 500 fm/c which corresponds to a sequential emission. This relatively long time which indicates a weak interaction between fragments, corresponds practically to the measurement threshold. The shortest intervals (about 50 fm/c) are associated to a spontaneous multifragmentation and were observed in the case of central collisions at Ar+Au and Kr+Au at 60 MeV/u. Two interpretations are possible. The multifragmentation process might be viewed as a sequential process of very short time-separation or else, one can separate two zones heaving in mind that the multifragmentation is predominant from 4,5 MeV/u excitation energy upwards. This question is still open and its study is under way at LPC. An answer could come from the study of the rupture process of an excited nucleus, notably by the determination of its life-time

  11. Passive Time Coincidence Measurements with HEU and DU Metal Castings

    International Nuclear Information System (INIS)

    McConchie, Seth M.; Hausladen, Paul; Mihalczo, John T.; Wright, Michael C.; Archer, Daniel E.

    2008-01-01

    A Department of Energy sponsored Oak Ridge National Laboratory/Y-12 National Security Complex program of passive time coincidence measurements has been initiated at Y-12 to evaluate the ability to determine the presence of high enriched uranium (HEU) and distinguish it from depleted uranium (DU). This program uses the Nuclear Materials Identification System (NMIS) without an active interrogation source. Previous passive NMIS measurements with Pu metal and Pu oxide have been successful in determining the Pu mass, assuming a known 240Pu content. The spontaneous fission of uranium metal is considerably lower than Pu and measurements of this type have been performed at Lawrence Livermore National Laboratory. This work presents results of measurements of HEU and DU metal castings using moderated 3He detectors.

  12. Decay Time Measurement for Different Energy Depositions of Plastic Scintillator Fabricated by High Temperature Polymerization Reaction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheol Ho; Son, Jaebum; Lee, Sangmin; Kim, Tae Hoon; Kim, Yong-Kyun [Hanyang University, Seoul (Korea, Republic of)

    2016-10-15

    Plastic scintillators are based on organic fluorite. They have many advantages such as fast rise and decay time, high optical transmission, ease of manufacturing, low cost, and large available size. For these reasons they are widely used for particle identification. Also, protection of people against a variety of threats (such as nuclear, radiological, and explosive) represents a true challenge along with the continuing development of science and technology. The plastic scintillator is widely used in various devise, which serves for nuclear, photonics, quantum, and high-energy physics. The plastic scintillator is probably the most widely used organic detector, and polystyrene is one of the most widely used materials in the making of the plastic scintillator detector. Thus, a styrene monomer as a solvent was used to fabricate the plastic scintillator by using high temperature polymerization reaction, and then the emission wavelength and the decay times for different energy depositions were measured by using the fabricated plastic scintillator. A plastic scintillator was fabricated to measure decay time for different energy depositions using the high temperature polymerization. Emission wavelength was measured of 426.05 nm to confirm a scintillator property using the spectrophotometer. Four gamma-ray sources (Cs-137, Co-60, Na-22, and Ba-133) were used to evaluate effect for decay time of different energy depositions. The average decay time of the fabricated plastic scintillator was measured to approximately 4.72 ns slightly higher more than commercial plastic scintillator. In future, light output and linearity will be measured to evaluate other property compared with the commercial scintillator.

  13. Decay Time Measurement for Different Energy Depositions of Plastic Scintillator Fabricated by High Temperature Polymerization Reaction

    International Nuclear Information System (INIS)

    Lee, Cheol Ho; Son, Jaebum; Lee, Sangmin; Kim, Tae Hoon; Kim, Yong-Kyun

    2016-01-01

    Plastic scintillators are based on organic fluorite. They have many advantages such as fast rise and decay time, high optical transmission, ease of manufacturing, low cost, and large available size. For these reasons they are widely used for particle identification. Also, protection of people against a variety of threats (such as nuclear, radiological, and explosive) represents a true challenge along with the continuing development of science and technology. The plastic scintillator is widely used in various devise, which serves for nuclear, photonics, quantum, and high-energy physics. The plastic scintillator is probably the most widely used organic detector, and polystyrene is one of the most widely used materials in the making of the plastic scintillator detector. Thus, a styrene monomer as a solvent was used to fabricate the plastic scintillator by using high temperature polymerization reaction, and then the emission wavelength and the decay times for different energy depositions were measured by using the fabricated plastic scintillator. A plastic scintillator was fabricated to measure decay time for different energy depositions using the high temperature polymerization. Emission wavelength was measured of 426.05 nm to confirm a scintillator property using the spectrophotometer. Four gamma-ray sources (Cs-137, Co-60, Na-22, and Ba-133) were used to evaluate effect for decay time of different energy depositions. The average decay time of the fabricated plastic scintillator was measured to approximately 4.72 ns slightly higher more than commercial plastic scintillator. In future, light output and linearity will be measured to evaluate other property compared with the commercial scintillator

  14. Real-time temperature field measurement based on acoustic tomography

    International Nuclear Information System (INIS)

    Bao, Yong; Jia, Jiabin; Polydorides, Nick

    2017-01-01

    Acoustic tomography can be used to measure the temperature field from the time-of-flight (TOF). In order to capture real-time temperature field changes and accurately yield quantitative temperature images, two improvements to the conventional acoustic tomography system are studied: simultaneous acoustic transmission and TOF collection along multiple ray paths, and an offline iteration reconstruction algorithm. During system operation, all the acoustic transceivers send modulated and filtered wideband Kasami sequences simultaneously to facilitate fast and accurate TOF measurements using cross-correlation detection. For image reconstruction, the iteration process is separated and executed offline beforehand to shorten computation time for online temperature field reconstruction. The feasibility and effectiveness of the developed methods are validated in the simulation study. The simulation results demonstrate that the proposed method can reduce the processing time per frame from 160 ms to 20 ms, while the reconstruction error remains less than 5%. Hence, the proposed method has great potential in the measurement of rapid temperature change with good temporal and spatial resolution. (paper)

  15. Real-time hostile attribution measurement and aggression in children.

    Science.gov (United States)

    Yaros, Anna; Lochman, John E; Rosenbaum, Jill; Jimenez-Camargo, Luis Alberto

    2014-01-01

    Hostile attributions are an important predictor of aggression in children, but few studies have measured hostile attributions as they occur in real-time. The current study uses an interactive video racing game to measure hostile attributions while children played against a presumed peer. A sample of 75 children, ages 10-13, used nonverbal and verbal procedures to respond to ambiguous provocation by their opponent. Hostile attributions were significantly positively related to parent-rated reactive aggression, when controlling for proactive aggression. Hostile attributions using a nonverbal response procedure were negatively related to proactive aggression, when controlling for reactive aggression. Results suggest hostile attributions in real-time occur quickly and simultaneously with social interaction, which differs from the deliberative, controlled appraisals measured with vignette-based instruments. The relation between real-time hostile attributions and reactive aggression could be accounted for by the impulsive response style that is characteristic of reactive aggression, whereas children exhibiting proactive aggression may be more deliberate and intentional in their responding, resulting in a negative relation with real-time hostile attributions. These findings can be used both to identify children at risk for aggression and to enhance preventive interventions. © 2014 Wiley Periodicals, Inc.

  16. The Measurement and Interpretation of Surface Wave Group Arrival Times

    Science.gov (United States)

    Masters, G.; Kane, D.; Morrow, J.; Zhou, Y.; Tromp, J.

    2005-12-01

    We have recently developed an efficient technique for measuring the relative group arrival times of surface waves by using cross-correlation and cluster analysis of waveform envelope functions. Applying the analysis to minor arc Love and Rayleigh waves in the frequency band 7 to 35 mHz for all events over magnitude 5.5 results in a dataset of over 200,000 measurements at each frequency for long period Rayleigh waves (frequency less than 25 mHz) and about 100,000 measurements at the shorter periods. Analysis of transverse components results in about half as many Love wave measurements. Simple ray theory inversions of the relative arrival times for apparent group velocity produce maps which are accurate representations of the data (often over 90% variance reduction of the relative arrival times) and which show features strongly correlated with tectonics and crustal thickness. The apparent group velocity variations can be extremely large: 30% velocity variations for 20 mHz Rayleigh waves and 40% variations for 30 mHz Rayleigh waves and can have abrupt lateral changes. This raises the concern that non-ray theory effects could be important. Indeed, a recent analysis by Dahlen and Zhou (personal communication) suggests that the group arrival times should be a functions of both the group velocity AND the phase velocity. The simplest way to test the interpretation of the measurements is to perform the analysis on synthetic seismograms computed for a realistic model of the Earth. Here, we use the SEM with a model which incorporates realistic crust and mantle structure. We are currently computing synthetics for a suite of roughly 1000 events recorded globally that extend to a period of 18 seconds. We shall present the results of applying both ray-based and finite frequency inversions to the synthetic data as well as evaluating the effects of off path propagation at short periods using surface wave ray tracing.

  17. [Measuring nursing care times--methodologic and documentation problems].

    Science.gov (United States)

    Bartholomeyczik, S; Hunstein, D

    2001-08-01

    The time for needed nursing care is one important measurement as a basic for financing care. In Germany the Long Term Care Insurance (LTCI) reimburses nursing care depending on the time family care givers need to complete selected activities. The LTCI recommends certain time ranges for these activities, which are wholly compensatory, as a basic for assessment. The purpose is to enhance assessment justice and comparability. With the example of a German research project, which had to investigate the duration of these activities and the reasons for differences, questions are raised about some definition and interpretation problems. There are definition problems, since caring activities especially in private households are nearly never performed as clearly defined modules. Moreover, often different activities are performed simultaneously. However, the most important question is what exactly time numbers can say about the essentials of nursing care.

  18. Real-time measurement and control at Jet. Experiment Control

    International Nuclear Information System (INIS)

    Felton, R.; Zabeo, L.; Sartori, F.; Piccolo, F.; Farthing, J.; Budd, T.; Dorling, S.; McCullen, P.; Harling, J.; Dalley, S.; Goodyear, A.; Stephen, A.; Card, P.; Bright, M.; Lucock, R.; Jones, E.; Griph, S.; Hogben, C.; Beldishevski, M.; Buckley, M.; Davis, J.; Young, I.; Hemming, O.; Wheatley, M.; Heesterman, P.; Lloyd, G.; Walters, M.; Bridge, R.; Leggate, H.; Howell, D.; Zastrow, K.D.; Giroud, C.; Coffey, I.; Hawkes, N.; Stamp, M.; Barnsley, R.; Edlington, T.; Guenther, K.; Gowers, C.; Popovichef, S.; Huber, A.; Ingesson, C.; Joffrin, E.; Mazon, D.; Moreau, D.; Murari, A.; Riva, M.; Barana, O.; Bolzonella, T.; Valisa, M.; Innocente, P.; Zerbini, M.; Bosak, K.; Blum, J.; Vitale, E.; Crisanti, F.; La Luna, E. de; Sanchez, J.

    2004-01-01

    Over the past few ears, the preparation of ITER-relevant plasma scenarios has been the main focus experimental activity on tokamaks. The development of integrated, simultaneous, real-time controls of plasma shape, current, pressure, temperature, radiation, neutron profiles, and also impurities, ELMs (edge localized modes) and MHD are now seen to be essential for further development of quasi-steady state conditions with feedback, or the stabilisation of transient phenomena with event-driven actions. For this thrust, the EFDA JET Real Time Project has developed a set of real-time plasma measurements, experiment control, and communication facilities. The Plasma Diagnostics used for real-time experiments are Far Infra Red interferometry, polarimetry, visible, UV and X-ray spectroscopy, LIDAR, bolometry, neutron and magnetics. Further analysis systems produce integrated results such as temperature profiles on geometry derived from MHD equilibrium solutions. The Actuators include toroidal, poloidal and divertor coils, gas and pellet fuelling, neutral beam injection, radiofrequency (ICRH) waves and microwaves (LH). The Heating/Fuelling Operators can either define a power or gas request waveform or select the real-time instantaneous power/gas request from the Real Time Experiment Central Control (RTCC) system. The Real Time Experiment Control system provides both a high-level, control-programming environment and interlocks with the actuators. A MATLAB facility is being developed for the development of more complex controllers. The plasma measurement, controller and plant control systems communicate in ATM network. The EFDA Real Time project is essential groundwork for future reactors such as ITER. It involves many staff from several institutions. The facility is now frequently used in experiments. (authors)

  19. Finding Rising and Falling Words

    NARCIS (Netherlands)

    Tjong Kim Sang, E.

    2016-01-01

    We examine two different methods for finding rising words (among which neologisms) and falling words (among which archaisms) in decades of magazine texts (millions of words) and in years of tweets (billions of words): one based on correlation coefficients of relative frequencies and time, and one

  20. Material Classification Using Raw Time-of-Flight Measurements

    KAUST Repository

    Su, Shuochen

    2016-12-13

    We propose a material classification method using raw time-of-flight (ToF) measurements. ToF cameras capture the correlation between a reference signal and the temporal response of material to incident illumination. Such measurements encode unique signatures of the material, i.e. the degree of subsurface scattering inside a volume. Subsequently, it offers an orthogonal domain of feature representation compared to conventional spatial and angular reflectance-based approaches. We demonstrate the effectiveness, robustness, and efficiency of our method through experiments and comparisons of real-world materials.

  1. Measurement of the residence time distribution in industrial flotation equipment

    International Nuclear Information System (INIS)

    Yianatos, Juan; Diaz, F; Rodriguez, Jorge

    2003-01-01

    This work presents a determination of the effective liquid and solid residence time in mechanical cell banks of primary and sweep flotation, and in cleaning flotation columns, at Codelco-Chile's Salvador Division. The determination was carried out using the residence time distribution (RTD) measurement with radioactive tracers. Br-82 was used as the trace element for the liquid. Different kinds of minerals were used to trace the solid: a) activated global tailing (non floatable), b) tailing activated by size classifications (non floatable) and c) activated floatable mineral. The residence time measurement defined effective volumes of 50-80% of the total volume in flotation cell banks, and effective volumes of 77% of the total volume of large-size flotation solids. The effective residence time of the solid (23%+212 microns) in industrial flotation cell banks was 5% below that for the liquid. The residence time of the mineral decreased with increased particle size. Thick mineral (>150 microns) showed a residence time 8% below that for thin mineral (<45 microns). The RTD of industrial mechanical cell banks is adequately represented with a number of perfect mixers in series equivalent to the number of real bank cells. The RTD of the industrial columns equals less than two perfect mixers in series and adjusts better when considering a perfect mixers in series model, but in a different size. Common operating problems could also be observed and analyzed through the RTD measurement, such as embankment of the equipment and the deficient regulation of the outflow, used to control the pulp level (Cw)

  2. Time poverty in Brazil: measurement and analysis of its determinants

    Directory of Open Access Journals (Sweden)

    Lilian Lopes Ribeiro

    2012-06-01

    Full Text Available This article analyzes well-being on an individual level, through the allocation of work hours done by adults and children and thus it measures time poverty in Brazil. In order to achieve such measurement, poverty indicators such as Foster, Greer and Thorbecke (FGT were adapted into a time poverty mode. Additionally, an analysis of its determinants was also conducted. Among other findings, the fact that women (either children and adult ones are the time-poorest individuals in urban or rural areas. Another unfortunate finding is that the high rate of time poverty among children, numerically 16,1% is not far from the adult rate which is of 19,7%. The overall composite time poor individual profile is of an African-Brazilian adult woman of little education, not necessarily income poor and residing in an urban area of the northeast region, living in a household of few people, she is the mother of children who are younger than 14 years old.

  3. Real time operation of a multiple gamma measurement installation

    International Nuclear Information System (INIS)

    Philippot, J.C.; Lefevre, J.

    1980-01-01

    This paper describes a multiple measurement channel facility for fine gamma spectrometry, its real time operation, and the new possibilities which it offers. The installation is presented in its twofold electronic and processing aspects, by considering its architecture, its hard and software, and its data processing package. Real time operation requires customized general organization, perfect instantaneous knowledge of the status of all the units, and a sound hierarchy between the various participants, operators as well as requestors. The care inherent in the installation itself and in the definition of its operation explains its new possibilities. (Auth.)

  4. Time-dependent coolant velocity measurements in an operating BWR

    International Nuclear Information System (INIS)

    Luebbesmeyer, D.; Crowe, R.D.

    1980-01-01

    A method to measure time-dependent fluid velocities in BWR-bundle elements by noise analysis of the incore-neutron-detector signals is shown. Two application examples of the new method are given. The time behaviour of the fluid velocity in the bundle element during a scheduled power excursion of the plant. The change of power was performed by changing the coolant flow through the core The apparent change of the fluid velocity due to thermal elongation of the helix-drive of the TIP-system. A simplified mathematical model was derived for this elongation to use as a reference to check the validity of the new method. (author)

  5. CFD simulation of homogenisation time measured by radiotracers

    International Nuclear Information System (INIS)

    Thyn, J.; Novy, M.; Zitny, R.; Mostik, M.; Jahoda, M.

    2004-01-01

    A methodology for CFD (Computational Fluid Dynamics) simulation of radiotracer experiments was suggested. The most important parts of the methodology for validation of CFD results by radiotracers are: a) successful simulation of tracer experiment by CFD code (numerical solution of tracer dispersion in a stirred tank), which results in tracer concentration field at several time intervals; b) post-process data treatment, which uses detection chain description and which enables to simulate the detector measurement of homogenisation time from the tracer concentration field evaluated by CFD code. (author)

  6. Density measurements of microsecond-conduction-time POS plasmas

    International Nuclear Information System (INIS)

    Hinshelwood, D.; Goodrich, P.J.; Weber, B.V.; Commisso, R.J.; Grossmann, J.M.; Kellogg, J.C.

    1993-01-01

    Measurements of the electron density in a coaxial microsecond conduction time plasma opening switch during switch operation are described. Current conduction is observed to cause a radial redistribution of the switch plasma. A local reduction in axial line density of more than an order of magnitude occurs by the time opening begins. This reduction, and the scaling of conduction current with plasma density, indicate that current conduction in this experiment is limited by hydrodynamic effects. It is hypothesized that the density reduction allows the switch to open by an erosion mechanism. Initial numerical modeling efforts have reproduced the principal observed results. A model that predicts accurately the conduction current is presented

  7. Application of real time spectrum measurement to radiation monitors

    International Nuclear Information System (INIS)

    Matsuno, K.; Watanabe, M.; Sakamaki, T.

    1996-01-01

    A multichannel analyzer (MCA) and two realtime spectrum monitoring methods have been developed for use in radiation monitors. The new MCA was designed to be installed at a local site as a component of a radiation monitor. The MCA repeats spectrum measurement at short intervals (Δt) and, after each measurement, transmits a spectrum datum to the operation console. The authors applied two methods to process Δt spectrum counts for each channel for longer time interval. One method of processing counts is the 'running average (RA) method'. The other method is the 'exponential smoothing (ES) method', which simulates RC rate meters by subtracting a fraction corresponding to the accumulated counts. Relative standard deviations for each channel can be made the same by selecting an appropriate value. The response with the 'ES' method is initially faster than that with the 'RA' method, but the 'RA' method allows a full response to be reached at a predictable time. (author)

  8. Three measures of longevity: time trends and record values

    DEFF Research Database (Denmark)

    Canudas-Romo, V

    2010-01-01

    at birth increased from a level of 44 years in Sweden in 1840 to 82 years in Japan in 2005. The record median age at death shows increasing patterns similar to those observed in life expectancy at birth. However, the record modal age at death changes very little until the second half of the twentieth......This article examines the trend over time in the measures of “typical” longevity experienced by members of a population: life expectancy at birth, and the median and modal ages at death. The article also analyzes trends in record values observed for all three measures. The record life expectancy...... time from a dominance of child mortality reductions to a dominance of adult mortality reductions, which became evident by studying trends in the record modal age at death....

  9. Coherence measures in automatic time-migration velocity analysis

    International Nuclear Information System (INIS)

    Maciel, Jonathas S; Costa, Jessé C; Schleicher, Jörg

    2012-01-01

    Time-migration velocity analysis can be carried out automatically by evaluating the coherence of migrated seismic events in common-image gathers (CIGs). The performance of gradient methods for automatic time-migration velocity analysis depends on the coherence measures used as the objective function. We compare the results of four different coherence measures, being conventional semblance, differential semblance, an extended differential semblance using differences of more distant image traces and the product of the latter with conventional semblance. In our numerical experiments, the objective functions based on conventional semblance and on the product of conventional semblance with extended differential semblance provided the best velocity models, as evaluated by the flatness of the resulting CIGs. The method can be easily extended to anisotropic media. (paper)

  10. Discrete time interval measurement system: fundamentals, resolution and errors in the measurement of angular vibrations

    International Nuclear Information System (INIS)

    Gómez de León, F C; Meroño Pérez, P A

    2010-01-01

    The traditional method for measuring the velocity and the angular vibration in the shaft of rotating machines using incremental encoders is based on counting the pulses at given time intervals. This method is generically called the time interval measurement system (TIMS). A variant of this method that we have developed in this work consists of measuring the corresponding time of each pulse from the encoder and sampling the signal by means of an A/D converter as if it were an analog signal, that is to say, in discrete time. For this reason, we have denominated this method as the discrete time interval measurement system (DTIMS). This measurement system provides a substantial improvement in the precision and frequency resolution compared with the traditional method of counting pulses. In addition, this method permits modification of the width of some pulses in order to obtain a mark-phase on every lap. This paper explains the theoretical fundamentals of the DTIMS and its application for measuring the angular vibrations of rotating machines. It also displays the required relationship between the sampling rate of the signal, the number of pulses of the encoder and the rotating velocity in order to obtain the required resolution and to delimit the methodological errors in the measurement

  11. The fission time scale measured with an atomic clock

    NARCIS (Netherlands)

    Kravchuk, VL; Wilschut, HW; Hunyadi, M; Kopecky, S; Lohner, H; Rogachevskiy, A; Siemssen, RH; Krasznahorkay, A; Hamilton, JH; Ramayya, AV; Carter, HK

    2003-01-01

    We present a new direct method of measuring the fission absolute time scale using an atomic clock based on the lifetime of a vacancy in the atomic K-shell. We studied the reaction Ne-20 + Th-232 -> O-16 + U-236* at 30 MeV/u. The excitation energy of about 115 MeV in such a reaction is in the range

  12. Time-resolved spectral measurements above 80 A

    International Nuclear Information System (INIS)

    Kauffman, R.L.; Ceglio, N.; Medecki, H.

    1983-01-01

    We have made time-resolved spectral measurements above 80 A from laser-produced plasmas. These are made using a transmission grating spectrograph whose primary components are a cylindrically-curved x-ray mirror for light collection, a transmission grating for spectral dispersions, and an x-ray streak camera for temporal resolution. A description of the instrument and an example of the data are given

  13. Change of Measure between Light Travel Time and Euclidean Distances

    Directory of Open Access Journals (Sweden)

    Heymann Y.

    2013-04-01

    Full Text Available The problem of cosmological distances is approached using a method based on the propagation of light in an expanding Universe. From the chan ge of measure between Light Travel Time and Euclidean Distances, a formula is deri ved to compute distances as a function of redshift. This formula is identical to Matti g’s formula (with q 0 = 1 / 2 which is based on Friedmann’s equations of general relativi ty.

  14. Time optimization of 90Sr measurements: Sequential measurement of multiple samples during ingrowth of 90Y

    International Nuclear Information System (INIS)

    Holmgren, Stina; Tovedal, Annika; Björnham, Oscar; Ramebäck, Henrik

    2016-01-01

    The aim of this paper is to contribute to a more rapid determination of a series of samples containing 90 Sr by making the Cherenkov measurement of the daughter nuclide 90 Y more time efficient. There are many instances when an optimization of the measurement method might be favorable, such as; situations requiring rapid results in order to make urgent decisions or, on the other hand, to maximize the throughput of samples in a limited available time span. In order to minimize the total analysis time, a mathematical model was developed which calculates the time of ingrowth as well as individual measurement times for n samples in a series. This work is focused on the measurement of 90 Y during ingrowth, after an initial chemical separation of strontium, in which it is assumed that no other radioactive strontium isotopes are present. By using a fixed minimum detectable activity (MDA) and iterating the measurement time for each consecutive sample the total analysis time will be less, compared to using the same measurement time for all samples. It was found that by optimization, the total analysis time for 10 samples can be decreased greatly, from 21 h to 6.5 h, when assuming a MDA of 1 Bq/L and at a background count rate of approximately 0.8 cpm. - Highlights: • An approach roughly a factor of three more efficient than an un-optimized method. • The optimization gives a more efficient use of instrument time. • The efficiency increase ranges from a factor of three to 10, for 10 to 40 samples.

  15. A comprehensive tool for measuring mammographic density changes over time.

    Science.gov (United States)

    Eriksson, Mikael; Li, Jingmei; Leifland, Karin; Czene, Kamila; Hall, Per

    2018-06-01

    Mammographic density is a marker of breast cancer risk and diagnostics accuracy. Density change over time is a strong proxy for response to endocrine treatment and potentially a stronger predictor of breast cancer incidence. We developed STRATUS to analyse digital and analogue images and enable automated measurements of density changes over time. Raw and processed images from the same mammogram were randomly sampled from 41,353 healthy women. Measurements from raw images (using FDA approved software iCAD) were used as templates for STRATUS to measure density on processed images through machine learning. A similar two-step design was used to train density measures in analogue images. Relative risks of breast cancer were estimated in three unique datasets. An alignment protocol was developed using images from 11,409 women to reduce non-biological variability in density change. The protocol was evaluated in 55,073 women having two regular mammography screens. Differences and variances in densities were compared before and after image alignment. The average relative risk of breast cancer in the three datasets was 1.6 [95% confidence interval (CI) 1.3-1.8] per standard deviation of percent mammographic density. The discrimination was AUC 0.62 (CI 0.60-0.64). The type of image did not significantly influence the risk associations. Alignment decreased the non-biological variability in density change and re-estimated the yearly overall percent density decrease from 1.5 to 0.9%, p density measures was not influenced by mammogram type. The alignment protocol reduced the non-biological variability between images over time. STRATUS has the potential to become a useful tool for epidemiological studies and clinical follow-up.

  16. NOTE ON TRAVEL TIME SHIFTS DUE TO AMPLITUDE MODULATION IN TIME-DISTANCE HELIOSEISMOLOGY MEASUREMENTS

    International Nuclear Information System (INIS)

    Nigam, R.; Kosovichev, A. G.

    2010-01-01

    Correct interpretation of acoustic travel times measured by time-distance helioseismology is essential to get an accurate understanding of the solar properties that are inferred from them. It has long been observed that sunspots suppress p-mode amplitude, but its implications on travel times have not been fully investigated so far. It has been found in test measurements using a 'masking' procedure, in which the solar Doppler signal in a localized quiet region of the Sun is artificially suppressed by a spatial function, and using numerical simulations that the amplitude modulations in combination with the phase-speed filtering may cause systematic shifts of acoustic travel times. To understand the properties of this procedure, we derive an analytical expression for the cross-covariance of a signal that has been modulated locally by a spatial function that has azimuthal symmetry and then filtered by a phase-speed filter typically used in time-distance helioseismology. Comparing this expression to the Gabor wavelet fitting formula without this effect, we find that there is a shift in the travel times that is introduced by the amplitude modulation. The analytical model presented in this paper can be useful also for interpretation of travel time measurements for the non-uniform distribution of oscillation amplitude due to observational effects.

  17. Study of calculated and measured time dependent delayed neutron yields

    International Nuclear Information System (INIS)

    Waldo, R.W.

    1980-05-01

    Time-dependent delayed neutron emission is of interest in reactor design, reactor dynamics, and nuclear physics studies. The delayed neutrons from neutron-induced fission of 232 U, 237 Np, 238 Pu, 241 Am, /sup 242m/Am, 245 Cm, and 249 Cf were studied for the first time. The delayed neutron emission from 232 Th, 233 U, 235 U, 238 U, 239 Pu, 241 Pu, and 242 Pu were measured as well. The data were used to develop an empirical expression for the total delayed neutron yield. The expression gives accurate results for a large variety of nuclides from 232 Th to 252 Cf. The data measuring the decay of delayed neutrons with time were used to derive another empirical expression predicting the delayed neutron emission with time. It was found that nuclides with similar mass-to-charge ratios have similar decay patterns. Thus the relative decay pattern of one nuclide can be established by any measured nuclide with a similar mass-to-charge ratio. A simple fission product yield model was developed and applied to delayed neutron precursors. It accurately predicts observed yield and decay characteristics. In conclusion, it is possible to not only estimate the total delayed neutron yield for a given nuclide but the time-dependent nature of the delayed neutrons as well. Reactors utilizing recycled fuel or burning actinides are likely to have inventories of fissioning nuclides that have not been studied until now. The delayed neutrons from these nuclides can now be incorporated so that their influence on the stability and control of reactors can be delineated. 8 figures, 39 tables

  18. Capital and time: uncertainty and qualitative measures of inequality.

    Science.gov (United States)

    Bear, Laura

    2014-12-01

    This review compares Piketty and Marx's approaches to capital and time in order to argue for the importance of qualitative measures of inequality. These latter measures emphasize varying experiences across classes and through history of uncertainty and insecurity. They explore how the social rhythms of capital profoundly affect the ability to plan a life-course. Quantitative measures such as those used by Piketty that focus on the amount of capital that accrues through time cannot capture such important phenomenon. This is especially because their calculations rest on absolute amounts of capital recorded in formal state statistics. Their limits are particularly revealed if we consider issues of: informal labour, social reproduction, and changing institutional forms of public debt. If we are to build the inter-disciplinary rapprochement between social science and economics that Piketty calls for it must be through asserting the value of qualitative measures of insecurity and its effects on decision making. These are important to track both at the macro-level of institutions and at the micro-level scale of human lives. It is, therefore, through emphasizing the existing strengths of both anthropology and history that we can meet Piketty's important challenge to make our scholarship relevant to current political and social debates. © London School of Economics and Political Science 2014.

  19. Simplified scintigraphic methods for measuring gastrointestinal transit times

    DEFF Research Database (Denmark)

    Graff, J; Brinch, K; Madsen, Jan Lysgård

    2000-01-01

    To investigate whether simple transit measurements based on scintigraphy performed only 0, 2, 4 and 24 h after intake of a radiolabelled meal can be used to predict the mean transit time values for the stomach, the small intestine, and the colon, a study was conducted in 16 healthy volunteers....... After ingestion of a meal containing 111indium-labelled water and 99mtechnetium-labelled omelette, imaging was performed at intervals of 30 min until all radioactivity was located in the colon and henceforth at intervals of 24 h until all radioactivity had cleared from the colon. Gastric, small...... intestinal and colonic mean transit times were calculated for both markers and compared with fractional gastric emptying at 2 h, fractional colonic filling at 4 h, and geometric centre of colonic content at 24 h, respectively. Highly significant correlations were found between gastric mean transit time...

  20. Time resolved mass flow measurements for a fast gas delivery system

    International Nuclear Information System (INIS)

    Ruden, E.L.; Degnan, J.H.; Hussey, T.W.; Scott, M.C.; Graham, J.D.; Coffey, S.K.

    1992-01-01

    A technique is demonstrated whereby the delivered mass and flow rate vs. time of a short rise time gas delivery system may be accurately determined. The gas mass M which flows past a point in a gas delivery system by an arbitrary time t may be accurately measured if that point is sealed off within a time interval short compared to the mass flow time scale. If the ejected mass is allowed to equilibrate in a known volume after being cut off from its source, a conventional static pressure measurement before and after injection, and application of the ideal gas law suffices. Assuming reproducibility, a time history M(t) may be generated, allowing the flow rate vs. time dM(t)/dt to be determined. Mass flow measurements are presented for a fast delivery system in which the flow of argon through a 3.2 mm I.D., 0.76 mm thick copper tube is cut off by imploding (θ pinching) the tube using a single turn tungsten magnetic field coil. Pinch discharge parameters are 44 μf, 20 kV, 47 nH, 3.5 mΩ, 584 kA, and 8.63 ps current period. Optical measurements of the tube's internal area vs. time indicate that the tube is sealed 2 ps from the time the tube is still 90% open (7 μs from the start of pinch current). The pinch delay is varied from 500--1,500 ps from the valve trigger (0--1,000 ps from the start of gas flow). The mass injected into the test volume is ∼ 100 μg during this interval. The leak rate of the sealed tube results in a mass increase of only ∼ 0.1 μg by the time the pressure gauge stabilizes (6 s). Results are correlated with piezoelectric probe measurements of the gas flow and 2-D axisymmetric numerical simulations of the θ pinch process. Simulations of a θ pinch suitable for characterizing an annular supersonic nozzle typical of those used in gas puff z pinches are discussed

  1. Timely resolved measurements on CdSe nanoparticles

    International Nuclear Information System (INIS)

    Holt, B.E. von

    2006-01-01

    By means of infrared spectroscopy the influence of the organic cover on structure and dynamics of CdSe nanoparticles was studied. First a procedure was developed, which allows to get from the static infrared spectrum informations on the quality of the organic cover and the binding behaviour of the ligands. On qualitatively high-grade and well characterized samples thereafter the dynamics of the lowest-energy electron level 1S e was time-resolvedly meausred in thew visible range. As reference served CdSe TOPO, which was supplemented by samples with the ligands octanthiole, octanic acid, octylamine, naphthoquinone, benzoquinone, and pyridine. The studied nanoparticles had a diameter of 4.86 nm. By means of the excitation-scanning or pump=probe procedure first measurements in the picosecond range were performed. The excitation wavelengths were thereby spectrally confined and so chosen that selectively the transitions 1S 3/2 -1S-e and 1P 3/2 -1P e but not the intermediately lyingt transition 2S 3/2 -1S e were excited. The excitation energies were kept so low that the excitation of several excitons in one crystal could be avoided. The scanning wavelength in the infrared corresponded to the energy difference between the electron levels 1S e and 1P e . The transients in the picosecond range are marked by a steep increasement of the signal, on which a multi-exponential decay follows. The increasement, which reproduces the popiulation of the excited state, isa inependent on the choice of the ligands. The influence of the organic cover is first visible in the different decay times of the excited electron levels. the decay of the measurement signal of CdSe TOPO can be approximatively described by three time constants: a decay constant in the early picosecond region, a time constant around hundert picoseconds, and a time constant of some nanoseconds. At increasing scanning wavelength the decay constants become longer. By directed excitation of the 1S 3/2 -1S e and the 1P 3

  2. Isothermal calorimeter for measurements of time-dependent heat generation rate in individual supercapacitor electrodes

    Science.gov (United States)

    Munteshari, Obaidallah; Lau, Jonathan; Krishnan, Atindra; Dunn, Bruce; Pilon, Laurent

    2018-01-01

    Heat generation in electric double layer capacitors (EDLCs) may lead to temperature rise and reduce their lifetime and performance. This study aims to measure the time-dependent heat generation rate in individual carbon electrode of EDLCs under various charging conditions. First, the design, fabrication, and validation of an isothermal calorimeter are presented. The calorimeter consisted of two thermoelectric heat flux sensors connected to a data acquisition system, two identical and cold plates fed with a circulating coolant, and an electrochemical test section connected to a potentiostat/galvanostat system. The EDLC cells consisted of two identical activated carbon electrodes and a separator immersed in an electrolyte. Measurements were performed on three cells with different electrolytes under galvanostatic cycling for different current density and polarity. The measured time-averaged irreversible heat generation rate was in excellent agreement with predictions for Joule heating. The reversible heat generation rate in the positive electrode was exothermic during charging and endothermic during discharging. By contrast, the negative electrode featured both exothermic and endothermic heat generation during both charging and discharging. The results of this study can be used to validate existing thermal models, to develop thermal management strategies, and to gain insight into physicochemical phenomena taking place during operation.

  3. A Time-Measurement System Based on Isotopic Ratios

    International Nuclear Information System (INIS)

    Vo, Duc T.; Karpius, P.J.; MacArthur, D.W.; Thron, J.L.

    2007-01-01

    A time-measurement system can be built based on the ratio of gamma-ray peak intensities from two radioactive isotopes. The ideal system would use a parent isotope with a short half-life decaying to a long half-life daughter. The activities of the parent-daughter isotopes would be measured using a gamma-ray detector system. The time can then be determined from the ratio of the activities. The best-known candidate for such a system is the 241 Pu- 241 Am parent-daughter pair. However, this 241 Pu- 241 Am system would require a high-purity germanium detector system and sophisticated software to separate and distinguish between the many gamma-ray peaks produced by the decays of the two isotopes. An alternate system would use two different isotopes, again one with a short half-life and one with a half-life that is long relative to the other. The pair of isotopes 210 Pb and 241 Am (with half-lives of 22 and 432 years, respectively) appears suitable for such a system. This time-measurement system operates by measuring the change in the ratio of the 47-keV peak of 210 Pb to the 60-keV peak of 241 Am. For the system to work reasonably well, the resolution of the detector would need to be such that the two gamma-ray peaks are well separated so that their peak areas can be accurately determined using a simple region-of-interest (ROI) method. A variety of detectors were tested to find a suitable system for this application. The results of these tests are presented here.

  4. Quantum trajectories and measurements in continuous time. The diffusive case

    International Nuclear Information System (INIS)

    Barchielli, Alberto; Gregoratti, Matteo

    2009-01-01

    This course-based monograph introduces the reader to the theory of continuous measurements in quantum mechanics and provides some benchmark applications. The approach chosen, quantum trajectory theory, is based on the stochastic Schroedinger and master equations, which determine the evolution of the a-posteriori state of a continuously observed quantum system and give the distribution of the measurement output. The present introduction is restricted to finite-dimensional quantum systems and diffusive outputs. Two appendices introduce the tools of probability theory and quantum measurement theory which are needed for the theoretical developments in the first part of the book. First, the basic equations of quantum trajectory theory are introduced, with all their mathematical properties, starting from the existence and uniqueness of their solutions. This makes the text also suitable for other applications of the same stochastic differential equations in different fields such as simulations of master equations or dynamical reduction theories. In the next step the equivalence between the stochastic approach and the theory of continuous measurements is demonstrated. To conclude the theoretical exposition, the properties of the output of the continuous measurement are analyzed in detail. This is a stochastic process with its own distribution, and the reader will learn how to compute physical quantities such as its moments and its spectrum. In particular this last concept is introduced with clear and explicit reference to the measurement process. The two-level atom is used as the basic prototype to illustrate the theory in a concrete application. Quantum phenomena appearing in the spectrum of the fluorescence light, such as Mollow's triplet structure, squeezing of the fluorescence light, and the linewidth narrowing, are presented. Last but not least, the theory of quantum continuous measurements is the natural starting point to develop a feedback control theory in

  5. Measuring and managing radiologist workload: measuring radiologist reporting times using data from a Radiology Information System

    International Nuclear Information System (INIS)

    Cowan, Ian A.; MacDonald, Sharon L.S.; Floyd, Richard A.

    2013-01-01

    Historically, there has been no objective method of measuring the time required for radiologists to produce reports during normal work. We have created a technique for semi-automated measurement of radiologist reporting time, and through it produced a robust set of absolute time requirements and relative value units for consultant reporting of diagnostic examinations in our hospital. A large sample of reporting times, recorded automatically by the Radiology Information System (COMRAD, Software Innovations, Christchurch, New Zealand) along with the description of each examination being reported, was placed in a database. Analysis was confined to diagnostic reporting by consultant radiologists. A spreadsheet was produced, listing the total number and the frequency of reporting times of each distinct examination. Outliers with exceptionally long report times (more than 10min for plain radiography, 30min for ultrasound, or 60min for CT or MRI with some exceptions) were culled; this removed 9.5% of the total. Complex CTs requiring separate workstation time were assigned times by consensus. The median time for the remainder of each sample was the assigned absolute reporting time in minutes and seconds. Relative value units were calculated using the reporting time for a single view department chest X-ray of 1min 38s including verifying a report made using speech recognition software. A schedule of absolute and relative values, based on over 179,000 reports, forms Table 2 of this paper. The technique provides a schedule of reporting times with reduced subjective input, which is more robust than existing systems for measuring reporting time.

  6. Characterization of irradiated APDs for picosecond time measurements

    Science.gov (United States)

    Centis Vignali, M.; Dalal, R.; Gallinaro, M.; Harrop, B.; Jain, G.; Lu, C.; McClish, M.; McDonald, K. T.; Moll, M.; Newcomer, F. M.; Ugobono, S. Otero; White, S.

    2018-01-01

    For their operation at the CERN High Luminosity Large Hadron Collider (HL-LHC), the ATLAS and CMS experiments are planning to implement dedicated systems to measure the time of arrival of minimum ionizing particles with an accuracy of about 30 ps. The timing detectors will be subjected to radiation levels corresponding up to a 1-MeV neutrons fluence (Φeq) of 1015 cm-2 for the goal integrated luminosity of HL-LHC of 3000 fb-1. In this paper, deep-diffused Avalanche Photo Diodes (APDs) produced by Radiation Monitoring Devices are examined as candidate timing detectors for HL-LHC applications. These APDs are operated at 1.8 kV, resulting in a gain of up to 500. The timing performance of the detectors is evaluated using a pulsed laser. The effects of radiation damage on current, signal amplitude, noise, and timing performance of the APDs are evaluated using detectors irradiated with neutrons up to Φeq = 1015 cm-2.

  7. An instrument for measuring doubling time; Un appareillage de mesure de temps de doublement

    Energy Technology Data Exchange (ETDEWEB)

    Ailloud, J; Chandanson, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-07-01

    The instrument described here allows the direct and almost immediate measurement, with a precision of the order of 1 per cent, of the time taken by a reactor to double its power. The method of measurement consists of noting the instants when the power of the reactor passes the levels P{sub 1} and P{sub 2} such that P{sub 2} = 2 P{sub 1}, and of measuring the time lapse between these two instants. The instrument picks out, in the course of one rise in power, several levels, P{sub 1}, P{sub 2}, P{sub 3}... etc, chosen in such a manner as to give several successive measurements of the doubling time. It is also capable of making these same measurements when the reactor is working below the critical level. (author) [French] L'appareil decrit ici permet la mesure directe et quasi immediate du temps de doublement de la puissance d'un reacteur avec une precision de l'ordre de 1 pour cent. La methode de mesure consiste a reperer les instants de passage de la puissance du reacteur par des niveaux P{sub 1} et P{sub 2} tels que P{sub 2} = 2 P{sub 1}, et a mesurer le temps ecoule entre ces deux instants. L'appareil repere, au cours d'une meme montee en puissance, plusieurs niveaux, P{sub 1}, P{sub 2}, P{sub 3}... etc, choisis de maniere a donner plusieurs mesures successives du temps de doublement. Il est egalement utilisable pour effectuer ces memes mesures lorsque le reacteur est en regime sous-critique. (auteur)

  8. Ignition delay time measurements of primary reference fuel blends

    KAUST Repository

    Alabbad, Mohammed

    2017-02-07

    Ignition delay times of four different primary reference fuels (PRF), mixtures of n-heptane and iso-octane, were measured behind reflected shock waves in a high-pressure shock tube facility. The PRFs were formulated to match the RON of two high-octane gasolines (RON 95 and 91) and two prospective low-octane naphtha fuels (RON 80 and 70). Experiments were carried out over a wide range of temperatures (700–1200K), pressures (10, 20, and 40bar) and equivalence ratios (0.5 and 1). Kinetic modeling predictions from four chemical kinetic mechanisms are compared with the experimental data. Ignition delay correlations are developed to reproduce the measured ignition delay times. Brute force sensitivity analyses are carried out to identify reactions that affect ignition delay times at specific temperature, pressure and equivalence ratio. The large experimental data set provided in the current work will serve as a benchmark for the validation of chemical kinetic mechanisms of primary reference fuel blends.

  9. Ignition delay time measurements of primary reference fuel blends

    KAUST Repository

    Alabbad, Mohammed; Javed, Tamour; Khaled, Fathi; Badra, Jihad; Farooq, Aamir

    2017-01-01

    Ignition delay times of four different primary reference fuels (PRF), mixtures of n-heptane and iso-octane, were measured behind reflected shock waves in a high-pressure shock tube facility. The PRFs were formulated to match the RON of two high-octane gasolines (RON 95 and 91) and two prospective low-octane naphtha fuels (RON 80 and 70). Experiments were carried out over a wide range of temperatures (700–1200K), pressures (10, 20, and 40bar) and equivalence ratios (0.5 and 1). Kinetic modeling predictions from four chemical kinetic mechanisms are compared with the experimental data. Ignition delay correlations are developed to reproduce the measured ignition delay times. Brute force sensitivity analyses are carried out to identify reactions that affect ignition delay times at specific temperature, pressure and equivalence ratio. The large experimental data set provided in the current work will serve as a benchmark for the validation of chemical kinetic mechanisms of primary reference fuel blends.

  10. MEASURING THE MASS OF SOLAR SYSTEM PLANETS USING PULSAR TIMING

    International Nuclear Information System (INIS)

    Champion, D. J.; Hobbs, G. B.; Manchester, R. N.; Edwards, R. T.; Burke-Spolaor, S.; Sarkissian, J. M.; Backer, D. C.; Bailes, M.; Bhat, N. D. R.; Van Straten, W.; Coles, W.; Demorest, P. B.; Ferdman, R. D.; Purver, M. B.; Folkner, W. M.; Hotan, A. W.; Kramer, M.; Lommen, A. N.; Nice, D. J.; Stairs, I. H.

    2010-01-01

    High-precision pulsar timing relies on a solar system ephemeris in order to convert times of arrival (TOAs) of pulses measured at an observatory to the solar system barycenter. Any error in the conversion to the barycentric TOAs leads to a systematic variation in the observed timing residuals; specifically, an incorrect planetary mass leads to a predominantly sinusoidal variation having a period and phase associated with the planet's orbital motion about the Sun. By using an array of pulsars (PSRs J0437-4715, J1744-1134, J1857+0943, J1909-3744), the masses of the planetary systems from Mercury to Saturn have been determined. These masses are consistent with the best-known masses determined by spacecraft observations, with the mass of the Jovian system, 9.547921(2) x10 -4 M sun , being significantly more accurate than the mass determined from the Pioneer and Voyager spacecraft, and consistent with but less accurate than the value from the Galileo spacecraft. While spacecraft are likely to produce the most accurate measurements for individual solar system bodies, the pulsar technique is sensitive to planetary system masses and has the potential to provide the most accurate values of these masses for some planets.

  11. Real-time scintillation probe measurement of left ventricular function

    International Nuclear Information System (INIS)

    Green, M.V.; Ostrow, H.G.; Bacharach, S.L.; Allen, S.I.; Bonow, R.O.; Johnston, G.S.

    1981-01-01

    The micro-processor based system described in this report was designed for maximum flexibility and utility. While the principle function of the system is to acquire, create, analyze and display (in real-time) left ventricular time activity (or volume) curves, provision is also made to acquire additional physiologic signals (e.g., ECG, flowmeter, etc.) and to calculate and display relationships between these various data. The system was designed for interactive use so that the system user can alter the course of a series of measurements based on previous results. These general capabilities are illustrated with several examples. In the first, LV function was measured continuously in a subject from (supine) rest through exercise and recovery. The second example illustrates the use of the system in acquiring (LV) pressure-volume loops. Several technical problems, such as correction for LV background radiation, appear at present to limit the probes applicability. Even now, however, probe systems are demonstrably useful in the study of global left ventricular function when this function is changing rapidly with time in response to various interventions. (orig.) [de

  12. Measurement of time processing ability and daily time management in children with disabilities.

    Science.gov (United States)

    Janeslätt, Gunnel; Granlund, Mats; Kottorp, Anders

    2009-01-01

    Improvement is needed in methods for planning and evaluating interventions designed to facilitate daily time management for children with intellectual disability, Asperger syndrome, or other developmental disorders. The aim of this study was to empirically investigate the hypothesized relation between children's time processing ability (TPA), daily time management, and self-rated autonomy. Such a relationship between daily time management and TPA may support the idea that TPA is important for daily time management and that children with difficulties in TPA might benefit from intervention aimed at improving daily time management. Participants were children aged 6 to 11 years with dysfunctions such as attention-deficit/hyperactivity disorder, autism, or physical or intellectual disabilities (N = 118). TPA was measured with the instrument KaTid. All data were transformed to interval measures using applications of Rasch models and then further analysed with correlation and regression analysis. The results demonstrate a moderate significant relation between the parents' ratings of daily time management and TPA of the children, and between the self-rating of autonomy and TPA. There was also a significant relation between self-ratings of autonomy and the parents' rating of the children's daily time management. Parents' ratings of their children's daily time management explain 25% of the variation in TPA, age of the children explains 22%, while the child's self-rating of autonomy can explain 9% of the variation in TPA. The three variables together explain 38% of the variation in TPA. The results indicate the viability of the instrument for assessing TPA also in children with disabilities and that the ability measured by KaTid is relevant for daily time management. TPA seems to be a factor for children's daily time management that needs to be taken into consideration when planning and evaluating interventions designed to facilitate everyday functioning for children with

  13. Quantum coherence in the time-resolved Auger measurement

    Energy Technology Data Exchange (ETDEWEB)

    Smirnova, Olga; Yakovlev, Vladislav S; Scrinzi, Armin

    2003-12-19

    We present a quantum mechanical model of the attosecond-XUV (extreme ultraviolet) pump and laser probe measurement of an Auger decay [Drescher et al., Nature (London) 419, 803 (2002)10.1038/nature01143] and investigate effects of quantum coherence. The time-dependent Schroedinger equation is solved by numerical integration and in analytic form. We explain the transition from a quasiclassical energy shift of the spectrum to the formation of sidebands and the enhancement of high- and low-energy tails of the Auger spectrum due to quantum coherence between photoionization and Auger decay.

  14. Some measurements of time and space correlation in wind tunnel

    Science.gov (United States)

    Favre, A; Gaviglio, J; Dumas, R

    1955-01-01

    Results are presented of research obtained by means of an apparatus for measurement of time and space correlation and of a spectral analyzer in the study of the longitudinal component of turbulence velocities in a wind tunnel downstream of a grid of meshes. Application to the case of a flat-plate boundary layer is illustrated. These researches were made at the Laboratoire de Mecanique de l'Atmosphere de l'I.M.F.M. for the O.N.E.R.A.

  15. Real-time deformation measurement using a transportable shearography system

    Science.gov (United States)

    Weijers, A. L.; van Brug, Hedser H.; Frankena, Hans J.

    1997-03-01

    A new system for deformation visualization has been developed, being a real time phase stepped shearing speckle interferometer. This system provides the possibility to measure quantitatively deformations of diffusely reflecting objects in an industrial environment. The main characteristics of this interferometer are its speed of operation and its reduced sensitivity to external disturbances. Apart from its semiconductor laser source, this system has a shoe-box size and is mounted on a tripod for easy handling during inspection. This paper describes the shearing speckle interferometry set-up, as it is developed at our laboratory and its potential for detecting defects.

  16. Theoretical information measurement in nonrelativistic time-dependent approach

    Science.gov (United States)

    Najafizade, S. A.; Hassanabadi, H.; Zarrinkamar, S.

    2018-02-01

    The information-theoretic measures of time-dependent Schrödinger equation are investigated via the Shannon information entropy, variance and local Fisher quantities. In our calculations, we consider the two first states n = 0,1 and obtain the position Sx (t) and momentum Sp (t) Shannon entropies as well as Fisher information Ix (t) in position and momentum Ip (t) spaces. Using the Fourier transformed wave function, we obtain the results in momentum space. Some interesting features of the information entropy densities ρs (x,t) and γs (p,t), as well as the probability densities ρ (x,t) and γ (p,t) for time-dependent states are demonstrated. We establish a general relation between variance and Fisher's information. The Bialynicki-Birula-Mycielski inequality is tested and verified for the states n = 0,1.

  17. Real-time evolvable pulse shaper for radiation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Lanchares, Juan, E-mail: julandan@dacya.ucm.es [Facultad de Informática, Universidad Complutense de Madrid (UCM), C/Prof. José García Santesmases s/n, 28040 Madrid (Spain); Garnica, Oscar, E-mail: ogarnica@dacya.ucm.es [Facultad de Informática, Universidad Complutense de Madrid (UCM), C/Prof. José García Santesmases s/n, 28040 Madrid (Spain); Risco-Martín, José L., E-mail: jlrisco@dacya.ucm.es [Facultad de Informática, Universidad Complutense de Madrid (UCM), C/Prof. José García Santesmases s/n, 28040 Madrid (Spain); Ignacio Hidalgo, J., E-mail: hidalgo@dacya.ucm.es [Facultad de Informática, Universidad Complutense de Madrid (UCM), C/Prof. José García Santesmases s/n, 28040 Madrid (Spain); Regadío, Alberto, E-mail: alberto.regadio@insa.es [Área de Tecnologías Electrónicas, Instituto Nacional de Técnica Aeroespacial (INTA), 28850 Torrejón de Ardoz, Madrid (Spain)

    2013-11-01

    In the last two decades, recursive algorithms for real-time digital pulse shaping in pulse height measurements have been developed and published in number of articles and textbooks. All these algorithms try to synthesize in real time optimum or near optimum shapes in the presence of noise. Even though some of these shapers can be considered effective designs, some side effects like aging cannot be ignored. We may observe that after sensors degradation, the signal obtained is not valid. In this regard, we present in this paper a novel technique that, based on evolvable hardware concepts, is able to evolve the degenerated shaper into a new design with better performance than the original one under the new sensor features.

  18. Time of flight measurement on the SOFIA experiment

    International Nuclear Information System (INIS)

    Bail, A.; Taieb, J.; Chatillon, A.; Belier, G.; Laurent, B.; Pellereau, E.

    2011-01-01

    The SOFIA experiment, which will be held at GSI (Darmstadt (Germany)) will allow to completely determine the mass and charge numbers of fragments produced in the fission reaction of radioactive actinides in reverse kinematics. Therefore, a dedicated setup has been developed for the Time of Flight measurement of relativistic heavy ions. The studies, which led to the choice of the adequate plastic scintillators and photomultipliers, are presented. Tests have been undertaken with the ELSA laser and electron beam facility. They shown that a suitable choice would be EJ-232 plastic scintillator for the ToF wall and EJ-232Q for the start detector and Hamamatsu H6533 and H10580 photomultipliers. This was confirmed by two test experiments realized at GSI with relativistic heavy ion beam ( 56 Fe and 238 U), where a time of flight resolution better than 20 ps FWHM was reached. (authors)

  19. Time of flight measurement on the SOFIA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Bail, A.; Taieb, J.; Chatillon, A.; Belier, G.; Laurent, B.; Pellereau, E. [CEA/DAM/DIF, Arpajon (France)

    2011-07-01

    The SOFIA experiment, which will be held at GSI (Darmstadt (Germany)) will allow to completely determine the mass and charge numbers of fragments produced in the fission reaction of radioactive actinides in reverse kinematics. Therefore, a dedicated setup has been developed for the Time of Flight measurement of relativistic heavy ions. The studies, which led to the choice of the adequate plastic scintillators and photomultipliers, are presented. Tests have been undertaken with the ELSA laser and electron beam facility. They shown that a suitable choice would be EJ-232 plastic scintillator for the ToF wall and EJ-232Q for the start detector and Hamamatsu H6533 and H10580 photomultipliers. This was confirmed by two test experiments realized at GSI with relativistic heavy ion beam ({sup 56}Fe and {sup 238}U), where a time of flight resolution better than 20 ps FWHM was reached. (authors)

  20. Multichannel FPGA based MVT system for high precision time (20 ps RMS) and charge measurement

    Science.gov (United States)

    Pałka, M.; Strzempek, P.; Korcyl, G.; Bednarski, T.; Niedźwiecki, Sz.; Białas, P.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gorgol, M.; Jasińska, B.; Kamińska, D.; Kajetanowicz, M.; Kowalski, P.; Kozik, T.; Krzemień, W.; Kubicz, E.; Mohhamed, M.; Raczyński, L.; Rudy, Z.; Rundel, O.; Salabura, P.; Sharma, N. G.; Silarski, M.; Smyrski, J.; Strzelecki, A.; Wieczorek, A.; Wiślicki, W.; Zieliński, M.; Zgardzińska, B.; Moskal, P.

    2017-08-01

    In this article it is presented an FPGA based Multi-Voltage Threshold (MVT) system which allows of sampling fast signals (1-2 ns rising and falling edge) in both voltage and time domain. It is possible to achieve a precision of time measurement of 20 ps RMS and reconstruct charge of signals, using a simple approach, with deviation from real value smaller than 10%. Utilization of the differential inputs of an FPGA chip as comparators together with an implementation of a TDC inside an FPGA allowed us to achieve a compact multi-channel system characterized by low power consumption and low production costs. This paper describes realization and functioning of the system comprising 192-channel TDC board and a four mezzanine cards which split incoming signals and discriminate them. The boards have been used to validate a newly developed Time-of-Flight Positron Emission Tomography system based on plastic scintillators. The achieved full system time resolution of σ(TOF) ≈ 68 ps is by factor of two better with respect to the current TOF-PET systems.

  1. Real-time heart rate measurement for multi-people using compressive tracking

    Science.gov (United States)

    Liu, Lingling; Zhao, Yuejin; Liu, Ming; Kong, Lingqin; Dong, Liquan; Ma, Feilong; Pang, Zongguang; Cai, Zhi; Zhang, Yachu; Hua, Peng; Yuan, Ruifeng

    2017-09-01

    The rise of aging population has created a demand for inexpensive, unobtrusive, automated health care solutions. Image PhotoPlethysmoGraphy(IPPG) aids in the development of these solutions by allowing for the extraction of physiological signals from video data. However, the main deficiencies of the recent IPPG methods are non-automated, non-real-time and susceptible to motion artifacts(MA). In this paper, a real-time heart rate(HR) detection method for multiple subjects simultaneously was proposed and realized using the open computer vision(openCV) library, which consists of getting multiple subjects' facial video automatically through a Webcam, detecting the region of interest (ROI) in the video, reducing the false detection rate by our improved Adaboost algorithm, reducing the MA by our improved compress tracking(CT) algorithm, wavelet noise-suppression algorithm for denoising and multi-threads for higher detection speed. For comparison, HR was measured simultaneously using a medical pulse oximetry device for every subject during all sessions. Experimental results on a data set of 30 subjects show that the max average absolute error of heart rate estimation is less than 8 beats per minute (BPM), and the processing speed of every frame has almost reached real-time: the experiments with video recordings of ten subjects under the condition of the pixel resolution of 600× 800 pixels show that the average HR detection time of 10 subjects was about 17 frames per second (fps).

  2. Measurement and correction of leaf open times in helical tomotherapy

    International Nuclear Information System (INIS)

    Sevillano, David; Mínguez, Cristina; Sánchez, Alicia; Sánchez-Reyes, Alberto

    2012-01-01

    Purpose: The binary multileaf collimator (MLC) is one of the most important components in helical tomotherapy (HT), as it modulates the dose delivered to the patient. However, methods to ensure MLC quality in HT treatments are lacking. The authors obtained data on the performance of the MLC in treatments administered in their department in order to assess possible delivery errors due to the MLC. Correction methods based on their data are proposed. Methods: Twenty sinograms from treatments delivered using both of the authors HT systems were measured and analyzed by recording the fluence collected by the imaging detector. Planned and actual sinograms were compared using distributions of leaf open time (LOT) errors, as well as differences in fluence reconstructed at each of the 51 projections into which the treatment planning system divides each rotation for optimization purposes. They proposed and applied a method based on individual leaf error correction and the increase in projection time to prevent latency effects when LOT is close to projection time. In order to analyze the dosimetric impact of the corrections, inphantom measurements were made for four corrected treatments. Results: The LOTs measured were consistent with those planned. Most of the mean errors in LOT distributions were within 1 ms with standard deviations of over 4 ms. Reconstructed fluences showed good results, with over 90% of points passing the 3% criterion, except in treatments with a short mean LOT, where the percentage of passing points was as low as 66%. Individual leaf errors were as long as 4 ms in some cases. Corrected sinograms improved error distribution, with standard deviations of over 3 ms and increased percentages of points passing 3% in the fluence per angle analysis, especially in treatments with a short mean LOT and those that were more subject to latency effects. The minimum percentage of points within 3% increased to 86%. In-phantom measurements of the corrected treatments

  3. Measurement and correction of leaf open times in helical tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Sevillano, David; Minguez, Cristina; Sanchez, Alicia; Sanchez-Reyes, Alberto [Department of Medical Physics, Tomotherapy Unit, Grupo IMO, Madrid 28010 (Spain)

    2012-11-15

    Purpose: The binary multileaf collimator (MLC) is one of the most important components in helical tomotherapy (HT), as it modulates the dose delivered to the patient. However, methods to ensure MLC quality in HT treatments are lacking. The authors obtained data on the performance of the MLC in treatments administered in their department in order to assess possible delivery errors due to the MLC. Correction methods based on their data are proposed. Methods: Twenty sinograms from treatments delivered using both of the authors HT systems were measured and analyzed by recording the fluence collected by the imaging detector. Planned and actual sinograms were compared using distributions of leaf open time (LOT) errors, as well as differences in fluence reconstructed at each of the 51 projections into which the treatment planning system divides each rotation for optimization purposes. They proposed and applied a method based on individual leaf error correction and the increase in projection time to prevent latency effects when LOT is close to projection time. In order to analyze the dosimetric impact of the corrections, inphantom measurements were made for four corrected treatments. Results: The LOTs measured were consistent with those planned. Most of the mean errors in LOT distributions were within 1 ms with standard deviations of over 4 ms. Reconstructed fluences showed good results, with over 90% of points passing the 3% criterion, except in treatments with a short mean LOT, where the percentage of passing points was as low as 66%. Individual leaf errors were as long as 4 ms in some cases. Corrected sinograms improved error distribution, with standard deviations of over 3 ms and increased percentages of points passing 3% in the fluence per angle analysis, especially in treatments with a short mean LOT and those that were more subject to latency effects. The minimum percentage of points within 3% increased to 86%. In-phantom measurements of the corrected treatments

  4. Real-Time Alpine Measurement System Using Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Sami A. Malek

    2017-11-01

    Full Text Available Monitoring the snow pack is crucial for many stakeholders, whether for hydro-power optimization, water management or flood control. Traditional forecasting relies on regression methods, which often results in snow melt runoff predictions of low accuracy in non-average years. Existing ground-based real-time measurement systems do not cover enough physiographic variability and are mostly installed at low elevations. We present the hardware and software design of a state-of-the-art distributed Wireless Sensor Network (WSN-based autonomous measurement system with real-time remote data transmission that gathers data of snow depth, air temperature, air relative humidity, soil moisture, soil temperature, and solar radiation in physiographically representative locations. Elevation, aspect, slope and vegetation are used to select network locations, and distribute sensors throughout a given network location, since they govern snow pack variability at various scales. Three WSNs were installed in the Sierra Nevada of Northern California throughout the North Fork of the Feather River, upstream of the Oroville dam and multiple powerhouses along the river. The WSNs gathered hydrologic variables and network health statistics throughout the 2017 water year, one of northern Sierra’s wettest years on record. These networks leverage an ultra-low-power wireless technology to interconnect their components and offer recovery features, resilience to data loss due to weather and wildlife disturbances and real-time topological visualizations of the network health. Data show considerable spatial variability of snow depth, even within a 1 km 2 network location. Combined with existing systems, these WSNs can better detect precipitation timing and phase in, monitor sub-daily dynamics of infiltration and surface runoff during precipitation or snow melt, and inform hydro power managers about actual ablation and end-of-season date across the landscape.

  5. Real-Time Alpine Measurement System Using Wireless Sensor Networks.

    Science.gov (United States)

    Malek, Sami A; Avanzi, Francesco; Brun-Laguna, Keoma; Maurer, Tessa; Oroza, Carlos A; Hartsough, Peter C; Watteyne, Thomas; Glaser, Steven D

    2017-11-09

    Monitoring the snow pack is crucial for many stakeholders, whether for hydro-power optimization, water management or flood control. Traditional forecasting relies on regression methods, which often results in snow melt runoff predictions of low accuracy in non-average years. Existing ground-based real-time measurement systems do not cover enough physiographic variability and are mostly installed at low elevations. We present the hardware and software design of a state-of-the-art distributed Wireless Sensor Network (WSN)-based autonomous measurement system with real-time remote data transmission that gathers data of snow depth, air temperature, air relative humidity, soil moisture, soil temperature, and solar radiation in physiographically representative locations. Elevation, aspect, slope and vegetation are used to select network locations, and distribute sensors throughout a given network location, since they govern snow pack variability at various scales. Three WSNs were installed in the Sierra Nevada of Northern California throughout the North Fork of the Feather River, upstream of the Oroville dam and multiple powerhouses along the river. The WSNs gathered hydrologic variables and network health statistics throughout the 2017 water year, one of northern Sierra's wettest years on record. These networks leverage an ultra-low-power wireless technology to interconnect their components and offer recovery features, resilience to data loss due to weather and wildlife disturbances and real-time topological visualizations of the network health. Data show considerable spatial variability of snow depth, even within a 1 km 2 network location. Combined with existing systems, these WSNs can better detect precipitation timing and phase in, monitor sub-daily dynamics of infiltration and surface runoff during precipitation or snow melt, and inform hydro power managers about actual ablation and end-of-season date across the landscape.

  6. AMPLITUDE AND TIME MEASUREMENT ASIC WITH ANALOG DERANDOMIZATION

    International Nuclear Information System (INIS)

    O CONNOR, P.; DE GERONIMO, G.; KANDASAMY, A.

    2002-01-01

    We describe a new ASIC for accurate and efficient processing of high-rate pulse signals from highly segmented detectors. In contrast to conventional approaches, this circuit affords a dramatic reduction in data volume through the use of analog techniques (precision peak detectors and time-to-amplitude converters) together with fast arbitration and sequencing logic to concentrate the data before digitization. In operation the circuit functions like a data-driven analog first-in, first-out (FIFO) memory between the preamplifiers and the ADC. Peak amplitudes of pulses arriving at any one of the 32 inputs are sampled, stored, and queued for readout and digitization through a single output port. Hit timing, pulse risetime, and channel address are also available at the output. Prototype chips have been fabricated in 0.35 micron CMOS and tested. First results indicate proper functionality for pulses down to 30 ns peaking time and input rates up to 1.6 MHz/channel. Amplitude accuracy of the peak detect and hold circuit is 0.3% (absolute). TAC accuracy is within 0.3% of full scale. Power consumption is less than 2 mW/channel. Compared with conventional techniques such as track-and-hold and analog memory, this new ASIC will enable efficient pulse height measurement at 20 to 300 times higher rates

  7. Modeling of GIC Impacts in Different Time Scales, and Validation with Measurement Data

    Science.gov (United States)

    Shetye, K.; Birchfield, A.; Overbye, T. J.; Gannon, J. L.

    2016-12-01

    Geomagnetically induced currents (GICs) have mostly been associated with geomagnetic disturbances (GMDs) originating from natural events such as solar coronal mass ejections. There is another, man-made, phenomenon that can induce GICs in the bulk power grid. Detonation of nuclear devices at high altitudes can give rise to electromagnetic pulses (EMPs) that induce electric fields at the earth's surface. EMPs cause three types of waves on different time scales, the slowest of which, E3, can induce GICs similar to the way GMDs do. The key difference between GMDs and EMPs is the rise time of the associated electric field. E3 electric fields are in the msec. to sec. range, whereas GMD electric fields are slower (sec. to min.). Similarly, the power grid and its components also operate and respond to disturbances in various time frames, right from electromagnetic transients (eg. lightning propagation) in the micro second range to steady state power flow ( hours). Hence, different power system component models need to be used to analyze the impacts of GICs caused by GMDs, and EMPs. For instance, for the slower GMD based GICs, a steady-state (static) analysis of the system is sufficient. That is, one does not need to model the dynamic components of a power system, such as the rotating machine of a generator, or generator controls such as exciters, etc. The latter become important in the case of an E3 EMP wave, which falls in the power system transient stability time frame of msec. to sec. This talk will first give an overview of the different time scales and models associated with power system operations, and where GMD and EMPs fit in. This is helpful to develop appropriate system models and test systems for analyzing impacts of GICs from various sources, and developing mitigation measures. Example test systems developed for GMD and EMP analysis, and their key modeling and analysis differences will be presented. After the modeling is discussed, results of validating

  8. EMPLOYEE COMMITMENT ACROSS COUNTRIES AND TIMES - MEASUREMENT INVARIANCE

    Directory of Open Access Journals (Sweden)

    Dana Mesner Andolšek

    2015-01-01

    Full Text Available Employee organisational commitment has been long and extensively studied until now (Meyer & Allen, 1997; Jaussi, 2007.An emphasis of current analysis was to verify its measurement characteristics, for the purpose of comparisons of levels of commitment across time and countries. A limited set of countries was chosen among those available in a sample from the data on Work Orientations II, ISSP 1997, purpose fully selected to reflect cultural and structural differences that was expected to affect change in levels of organisational commitment. With the use of structural equations models we first confirmed that a model for configural invariance for two factors measuring conceptually distinct components of Affective commitment (AC and Continuance commitment (CC respectively has better support than of one factor model. Metric and error term invariance was subsequently confirmed. Scalar equivalence, needed for valid comparison of mean levels of both components of commitment, was confirmed as well, with the exception of two country specific Tau coefficient. Finally, a model thus established was applied additionally on data from2005 ISSP. Acceptable fit was achieved for a common model containing both points in time and all countries, which allowed making more firm conclusions about the changes in AC and CC in different countries.

  9. Laser oriented 36K for time reversal symmetry measurements

    International Nuclear Information System (INIS)

    Young, A.R.; Anderson, W.S.; Calaprice, F.P.; Cates, G.D.; Jones, G.L.; Krieger, D.A.; Vogelaar, R.B.

    1995-01-01

    We have produced very large nuclear alignments in radioactive 36 K (half-life 0.34 sec) through laser optical pumping techniques. The 36 K was created through (p,n) reactions using a 50 nA, 22 MeV proton beam, and a 3.3 atmosphere 36 Ar target. Measurements were made with the target cell at room temperature, when direct optical pumping produces nuclear orientation in the 36 K, and at elevated temperatures 160 degree C and 180 degree C where the 36 K is oriented through a combination of direct optical pumping and spin exchange. The fraction of the maximal nuclear alignment for the 180 degree C data was determined to be 0.46±0.07 stat±0.05 syst through measurements of the γ-ray anisotropy following positron decay. Roughly 10 5 or more decays of oriented 36 K occurred each second. The application of the superallowed decay of 36 K to measurements of time-reversal symmetry in β decay is discussed

  10. Accuracy of real time radiography burning rate measurement

    Science.gov (United States)

    Olaniyi, Bisola

    The design of a solid propellant rocket motor requires the determination of a propellant's burning-rate and its dependency upon environmental parameters. The requirement that the burning-rate be physically measured, establishes the need for methods and equipment to obtain such data. A literature review reveals that no measurement has provided the desired burning rate accuracy. In the current study, flash x-ray modeling and digitized film-density data were employed to predict motor-port area to length ratio. The pre-fired port-areas and base burning rate were within 2.5% and 1.2% of their known values, respectively. To verify the accuracy of the method, a continuous x-ray and a solid propellant rocket motor model (Plexiglas cylinder) were used. The solid propellant motor model was translated laterally through a real-time radiography system at different speeds simulating different burning rates. X-ray images were captured and the burning-rate was then determined. The measured burning rate was within 1.65% of the known values.

  11. Time structure measurement of the ATLAS RPC gap current

    CERN Document Server

    Aielli, G; The ATLAS collaboration

    2010-01-01

    The current absorbed by an RPC represents the sum of the charge delivered in the gas by the ionizing events interesting the gap, integrated by the electrodes time constant. This is typically of the order of tens of ms thus dominating the gas discharge time scale and characterizing the granular structure observed in the current signal. In most cases this structure is considered as noise to be further integrated to observe the average gap current, used often as a detector monitoring parameter or to precisely measure the uncorrelated background rate effects. A remarkable case is given if a large number of particles is passing trough the detector within an integration time constant producing a current peak clearly detectable above the average noise. The ATLAS RPC system is equipped with a dedicated current monitoring based on an ADC capable of reading out the average value as well as the transient peaks of the currents above a given threshold. A study on such data was used to spot the gap HV noise, to monitor the...

  12. Femtosecond response time measurements of a Cs2Te photocathode

    Science.gov (United States)

    Aryshev, A.; Shevelev, M.; Honda, Y.; Terunuma, N.; Urakawa, J.

    2017-07-01

    Success in design and construction of a compact, high-brightness accelerator system is strongly related to the production of ultra-short electron beams. Recently, the approach to generate short electron bunches or pre-bunched beams in RF guns directly illuminating a high quantum efficiency semiconductor photocathode with femtosecond laser pulses has become attractive. The measurements of the photocathode response time in this case are essential. With an approach of the interferometer-type pulse splitter deep integration into a commercial Ti:Sa laser system used for RF guns, it has become possible to generate pre-bunched electron beams and obtain continuously variable electron bunch separation. In combination with a well-known zero-phasing technique, it allows us to estimate the response time of the most commonly used Cs2Te photocathode. It was demonstrated that the peak-to-peak rms time response of Cs2Te is of the order of 370 fs, and thereby, it is possible to generate and control a THz sequence of relativistic electron bunches by a conventional S-band RF gun. This result can also be applied for investigation of other cathode materials and electron beam temporal shaping and further opens a possibility to construct wide-range tunable, table-top THz free electron laser.

  13. Time dependency of local cerebral blood flow measurements caused by regional variations in tissue transit time

    International Nuclear Information System (INIS)

    Lear, J.L.; Kasliwal, R.; Feyerabend, A.

    1990-01-01

    Calculated values of local cerebral blood flow (LCBF) using the diffusible tracer model are assumed to be independent of time as long as experiments are brief enough to prevent tissue saturation. This paper investigates the effects of CTT variation on LCBF measurements. Using double-label quantitative digital autoradiography, we compared iodoantipyrine (IAP)-based LCBF measurements obtained with tracer infusions of different lengths of time. Lightly anesthetized rats were given simultaneous ramp infusions of C-14 IAP (45 seconds) and I-123 IAP (15 seconds) and immediately sacrificed. Two autoradiograms of each brain section, one representing I-123 and the other representing C-14, were produced, digitized, and converted into images of LCBF based on the 15- and 45-second infusion periods. The LCBF image pairs were compared on a pixel-by-pixel basis

  14. Credentialism, Adults, and Part-Time Higher Education in the United Kingdom: An Account of Rising Take Up and Some Implications for Policy.

    Science.gov (United States)

    Fuller, Alison

    2001-01-01

    Explains the growing importance of higher-level qualifications for adults in the UK, highlighting statistical trends in commitment to learning and qualifying-the result of taking part-time courses in higher education. Most part-time undergraduates fund their own tuition. Mature students' backgrounds and perspectives partly account for their rising…

  15. The measurement of the real part of the proton-antiproton elastic scattering amplitude at a C.M.S. energy of 546 GEV and the rise of the total cross section

    International Nuclear Information System (INIS)

    Kluit, P.M.

    1988-01-01

    The subject of this thesis is the experimental study of the elastic scattering of protons and anti-protons at a centre of mass energy of 546 GeV at the SPS (Super Proton Synchrotron) at CERN. The measurement of ρ, i.e. the ratio of the real to the imaginary part of the nuclear part of elastic scattering amplitude for proton-antiproton at zero momentum transfer squared (-t = 0 GeV 2 ), at a centre of mass energy of √s = 546 GeV is described. The implications of the result of this measurement for the behaviour of the total cross section in the TeV domain are derived. The hypothesis is investigated whether there is a relation between the rise of the total cross section and the rise of the total jet cross section, as calculated in perturbative QCD and observed by the UA1 experiment. 104 refs.; 40 figs.; 16 tabs

  16. Measuring physical inactivity: do current measures provide an accurate view of "sedentary" video game time?

    Science.gov (United States)

    Fullerton, Simon; Taylor, Anne W; Dal Grande, Eleonora; Berry, Narelle

    2014-01-01

    Measures of screen time are often used to assess sedentary behaviour. Participation in activity-based video games (exergames) can contribute to estimates of screen time, as current practices of measuring it do not consider the growing evidence that playing exergames can provide light to moderate levels of physical activity. This study aimed to determine what proportion of time spent playing video games was actually spent playing exergames. Data were collected via a cross-sectional telephone survey in South Australia. Participants aged 18 years and above (n = 2026) were asked about their video game habits, as well as demographic and socioeconomic factors. In cases where children were in the household, the video game habits of a randomly selected child were also questioned. Overall, 31.3% of adults and 79.9% of children spend at least some time playing video games. Of these, 24.1% of adults and 42.1% of children play exergames, with these types of games accounting for a third of all time that adults spend playing video games and nearly 20% of children's video game time. A substantial proportion of time that would usually be classified as "sedentary" may actually be spent participating in light to moderate physical activity.

  17. Time measurement - technical importance of most exact clocks

    International Nuclear Information System (INIS)

    Goebel, E.O.; Riehle, F.

    2004-01-01

    The exactness of the best atomic clocks currently shows a temporal variation of 1 second in 30 million years. This means that we have reached the point of the most exact frequency and time measurement ever. In the past, there was a trend towards increasing the exactness in an increasingly fast sequence. Will this trend continue? And who will profit from it? This article is meant to give answers to these questions. This is done by presenting first the level reached currently with the best atomic clocks and describing the research activities running worldwide with the aim of achieving even more exact clocks. In the second part, we present examples of various areas of technical subjects and research in which the most exact clocks are being applied presently and even more exact ones will be needed in the future [de

  18. Measuring urban sprawl in China by night time light images

    Science.gov (United States)

    Liu, Lu; Tang, Lin

    2017-01-01

    In the process of urbanization, a phenomenon called “urban sprawl” usually occurs. This phenomenon may exaggerated the negative effects of urbanization on environment, public and social health, energy efficiency, and maintenance of farmland. Therefore, the understanding of this phenomenon is urgently required for us to achieve sustainable development. This study proposed a group of night time lights (NTL) indicators of urban sprawl, which intend to use the distribution of lightness to quantify urban sprawl. These measures are proved to be efficient in describing urban sprawl. In addition, they are consistent and easy calculating, making comparison analysis easy to be done. These indicators are used to study urban sprawl in China during the year 2000 to 2010, the results show that in the last ten years, metropolitan areas in the northern part of China have undergone a more sprawl-like urban growth compared with other parts of China.

  19. Objectively measured physical activity and sedentary time in youth

    DEFF Research Database (Denmark)

    Cooper, Ashley R; Goodman, Anna; Page, Angie S

    2015-01-01

    .8-18.4 years) who provided at least three days of valid accelerometer data. Linear regression was used to examine associations between age, sex, weight status, country and physical activity outcomes. RESULTS: Boys were less sedentary and more active than girls at all ages. After 5 years of age......BACKGROUND: Physical activity and sedentary behaviour in youth have been reported to vary by sex, age, weight status and country. However, supporting data are often self-reported and/or do not encompass a wide range of ages or geographical locations. This study aimed to describe objectively......-measured physical activity and sedentary time patterns in youth. METHODS: The International Children's Accelerometry Database (ICAD) consists of ActiGraph accelerometer data from 20 studies in ten countries, processed using common data reduction procedures. Analyses were conducted on 27,637 participants (2...

  20. Holdup time measurement by radioactive tracers in pulp production

    International Nuclear Information System (INIS)

    Roetzer, H.; Donhoffer, D.

    1988-12-01

    A batch of pulp was to be labelled before passing two bleaching towers of a pulp plant. Activated glass fibres were used as a tracer, which contained 24-Na with a half-life of 15 hours. It was shown in laboratory tests, that the glass fibres were suitable for transport studies of wood pulp. For use in the tests the fibres were activated and suspended in water. Due to the small diameter of the fibres (2-5 micrometers) this suspension shows physical properties very similar to the pulp. For detection six scintillation probes were mounted at different positions outside the bleaching tower. Radiation protection during the test was very easy due to the low total activity of the tracer material. Residence time distributions for both towers were measured. The successful tracer experiments show, that the method of labelling is suited for investigations of material transport in the pulp and paper industry. 3 figs., 11 refs., 2 tabs. (Author)

  1. Mesospheric Water Vapor Retrieved from SABER/TIMED Measurements

    Science.gov (United States)

    Feofilov, Arte, G.; Yankovsky, Valentine A.; Marshall, Benjamin T.; Russell, J. M., III; Pesnell, W. D.; Kutepov, Alexander A.; Goldberg, Richard A.; Gordley, Larry L.; Petelina, Svetlama; Mauilova, Rada O.; hide

    2007-01-01

    The SABER instrument on board the TIMED satellite is a limb scanning infrared radiometer designed to measure temperature and minor constituent vertical profiles and energetics parameters in the mesosphere and lower thermosphere (MLT) The H2O concentrations are retrieved from 6.3 micron band radiances. The interpretation of this radiance requires developing a non-LTE H2O model that includes energy exchange processes with the system of O3 and O2 vibrational levels populated at the daytime through a number of photoabsorption and photodissociation processes. We developed a research model base on an extended H2O non-LTE model of Manuilova coupled with the novel model of the electronic kinetics of the O2 and O3 photolysis products suggested by Yankosvky and Manuilova. The performed study of this model helped u to develop and test an optimized operational model for interpretation of SABER 6.3 micron band radiances. The sensitivity of retrievals to the parameters of the model is discussed. The H2O retrievals are compared to other measurements for different seasons and locations.

  2. On the measurement of time-dependent quantum phases

    International Nuclear Information System (INIS)

    Barut, A.O.; Bozic, M.; Klarsfeld, S.; Maric, Z.

    1991-11-01

    We have evaluated the exact (Pancharatnam) phase differences between the final state l ψ(t) > and various initial states for a spin 1/2-particle in a rotating magnetic field B(t). For the initial states l n; B ef (0) >, which are eigenstates of the spin component along the direction of the initial effective field B ef (0), the exact phase has an energy dependent part, and an energy independent part. It is shown that these states l n; B ef (0) > are cyclic and their corresponding Aharonov-Anandan phases are evaluated. In the adiabatic limit we discuss different choices of time-dependent bases and the relationship between the exact phase, the Born-Fock-Schiff phase and Berry's phase. We propose experiments (neutron) to verify separately the exact and the adiabatic evolution laws, as well as to measure the adiabatic phases associated with different choices of time-dependent basis vectors. (author). 37 refs, 5 figs, 1 tab

  3. Time Delay Measurements for the Cluster-lensed Sextuple Quasar SDSS J2222+2745

    Science.gov (United States)

    Dahle, H.; Gladders, M. D.; Sharon, K.; Bayliss, M. B.; Rigby, J. R.

    2015-11-01

    We report first results from an ongoing monitoring campaign to measure time delays between the six images of the quasar SDSS J2222+2745, gravitationally lensed by a galaxy cluster. The time delay between A and B, the two most highly magnified images, is measured to be {τ }{{AB}}=47.7+/- 6.0 days (95% confidence interval), consistent with previous model predictions for this lens system. The strong intrinsic variability of the quasar also allows us to derive a time delay value of {τ }{{CA}}=722+/- 24 days between image C and A, in spite of modest overlap between their light curves in the current data set. Image C, which is predicted to lead all the other lensed quasar images, has undergone a sharp, monotonic flux increase of 60%-75% during 2014. A corresponding brightening is firmly predicted to occur in images A and B during 2016. The amplitude of this rise indicates that time delays involving all six known images in this system, including those of the demagnified central images D-F, will be obtainable from further ground-based monitoring of this system during the next few years. Based on observations made with the Nordic Optical Telescope, operated on the island of La Palma jointly by Denmark, Finland, Iceland, Norway, and Sweden, in the Spanish Observatorio del Roque de los Muchachos of the Instituto de Astrofisica de Canarias, and including observations obtained at the Gemini Observatory, which is operated by the Association of Universities for Research in Astronomy, Inc., under a cooperative agreement with the NSF on behalf of the Gemini partnership: the National Science Foundation (United States), the National Research Council (Canada), CONICYT (Chile), the Australian Research Council (Australia), Ministério da Ciência, Tecnologia e Inovação (Brazil) and Ministerio de Ciencia, Tecnologi´a e Innovación Productiva (Argentina).

  4. The Rise of Iran

    DEFF Research Database (Denmark)

    Rahigh-Aghsan, Ali

    Iran is viewed as a rising power that poses an increasing threat to regional and even global security. This view is wrong for three reasons. Iran's hard and soft power is exaggerated by most accounts; it is too limited to allow the Iranians to dominate the Persian Gulf let alone the Middle East...

  5. The Rise of Iran

    DEFF Research Database (Denmark)

    Rahigh-Aghsan, Ali; Jakobsen, Peter Viggo

    2010-01-01

    Iran is viewed as a rising power that poses an increasing threat to regional and even global security. This view is wrong for three reasons. Iran's hard and soft power is exaggerated by most accounts; it is too limited to allow the Iranians to dominate the Persian Gulf let alone the Middle East...

  6. A Reduced-Order Controller Considering High-Order Modal Information of High-Rise Buildings for AMD Control System with Time-Delay

    Directory of Open Access Journals (Sweden)

    Zuo-Hua Li

    2017-01-01

    Full Text Available Time-delays of control force calculation, data acquisition, and actuator response will degrade the performance of Active Mass Damper (AMD control systems. To reduce the influence, model reduction method is used to deal with the original controlled structure. However, during the procedure, the related hierarchy information of small eigenvalues will be directly discorded. As a result, the reduced-order model ignores the information of high-order mode, which will reduce the design accuracy of an AMD control system. In this paper, a new reduced-order controller based on the improved Balanced Truncation (BT method is designed to reduce the calculation time and to retain the abandoned high-order modal information. It includes high-order natural frequency, damping ratio, and vibration modal information of the original structure. Then, a control gain design method based on Guaranteed Cost Control (GCC algorithm is presented to eliminate the adverse effects of data acquisition and actuator response time-delays in the design process of the reduced-order controller. To verify its effectiveness, the proposed methodology is applied to a numerical example of a ten-storey frame and an experiment of a single-span four-storey steel frame. Both numerical and experimental results demonstrate that the reduced-order controller with GCC algorithm has an excellent control effect; meanwhile it can compensate time-delays effectively.

  7. Time Resolved Measurements of Primary Biogenic Aerosol Particles in Amazonia

    Science.gov (United States)

    Wollny, A. G.; Garland, R.; Pöschl, U.

    2009-04-01

    Biogenic aerosols are ubiquitous in the Earth's atmosphere and they influence atmospheric chemistry and physics, the biosphere, climate, and public health. They play an important role in the spread of biological organisms and reproductive materials, and they can cause or enhance human, animal, and plant diseases. Moreover, they influence the Earth's energy budget by scattering and absorbing radiation, and they can initiate the formation of clouds and precipitation as cloud condensation and ice nuclei. The composition, abundance, and origin of biogenic aerosol particles and components are, however, still not well understood and poorly quantified. Prominent examples of primary biogenic aerosol particles, which are directly emitted from the biosphere to the atmosphere, are pollen, bacteria, fungal spores, viruses, and fragments of animals and plants. During the Amazonian Aerosol Characterization Experiment (AMAZE-08) a large number of aerosol and gas-phase measurements were taken on a remote site close to Manaus, Brazil, during a period of five weeks in February and March 2008. This presented study is focused on data from an ultraviolet aerodynamic particle sizer (UVAPS, TSI inc.) that has been deployed for the first time in Amazonia. In this instrument, particle counting and aerodynamic sizing over the range of 0.5-20 µm are complemented by the measurement of UV fluorescence at 355 nm (excitation) and 420-575 nm (emission), respectively. Fluorescence at these wavelengths is characteristic for reduced pyridine nucleotides (e.g., NAD(P)H) and for riboflavin, which are specific for living cells. Thus particles exhibiting fluorescence signals can be regarded as "viable aerosols" or "fluorescent bioparticles" (FBAP), and their concentration can be considered as lower limit for the actual abundance of primary biogenic aerosol particles. Data from the UVAPS were averaged over 5 minute time intervals. The presence of bioparticles in the observed size range has been

  8. Measuring Stratigraphic Congruence Across Trees, Higher Taxa, and Time.

    Science.gov (United States)

    O'Connor, Anne; Wills, Matthew A

    2016-09-01

    The congruence between the order of cladistic branching and the first appearance dates of fossil lineages can be quantified using a variety of indices. Good matching is a prerequisite for the accurate time calibration of trees, while the distribution of congruence indices across large samples of cladograms has underpinned claims about temporal and taxonomic patterns of completeness in the fossil record. The most widely used stratigraphic congruence indices are the stratigraphic consistency index (SCI), the modified Manhattan stratigraphic measure (MSM*), and the gap excess ratio (GER) (plus its derivatives; the topological GER and the modified GER). Many factors are believed to variously bias these indices, with several empirical and simulation studies addressing some subset of the putative interactions. This study combines both approaches to quantify the effects (on all five indices) of eight variables reasoned to constrain the distribution of possible values (the number of taxa, tree balance, tree resolution, range of first occurrence (FO) dates, center of gravity of FO dates, the variability of FO dates, percentage of extant taxa, and percentage of taxa with no fossil record). Our empirical data set comprised 647 published animal and plant cladograms spanning the entire Phanerozoic, and for these data we also modeled the effects of mean age of FOs (as a proxy for clade age), the taxonomic rank of the clade, and the higher taxonomic group to which it belonged. The center of gravity of FO dates had not been investigated hitherto, and this was found to correlate most strongly with some measures of stratigraphic congruence in our empirical study (top-heavy clades had better congruence). The modified GER was the index least susceptible to bias. We found significant differences across higher taxa for all indices; arthropods had lower congruence and tetrapods higher congruence. Stratigraphic congruence-however measured-also varied throughout the Phanerozoic, reflecting

  9. Calibrating electromagnetic induction conductivities with time-domain reflectometry measurements

    Science.gov (United States)

    Dragonetti, Giovanna; Comegna, Alessandro; Ajeel, Ali; Piero Deidda, Gian; Lamaddalena, Nicola; Rodriguez, Giuseppe; Vignoli, Giulio; Coppola, Antonio

    2018-02-01

    This paper deals with the issue of monitoring the spatial distribution of bulk electrical conductivity, σb, in the soil root zone by using electromagnetic induction (EMI) sensors under different water and salinity conditions. To deduce the actual distribution of depth-specific σb from EMI apparent electrical conductivity (ECa) measurements, we inverted the data by using a regularized 1-D inversion procedure designed to manage nonlinear multiple EMI-depth responses. The inversion technique is based on the coupling of the damped Gauss-Newton method with truncated generalized singular value decomposition (TGSVD). The ill-posedness of the EMI data inversion is addressed by using a sharp stabilizer term in the objective function. This specific stabilizer promotes the reconstruction of blocky targets, thereby contributing to enhance the spatial resolution of the EMI results in the presence of sharp boundaries (otherwise smeared out after the application of more standard Occam-like regularization strategies searching for smooth solutions). Time-domain reflectometry (TDR) data are used as ground-truth data for calibration of the inversion results. An experimental field was divided into four transects 30 m long and 2.8 m wide, cultivated with green bean, and irrigated with water at two different salinity levels and using two different irrigation volumes. Clearly, this induces different salinity and water contents within the soil profiles. For each transect, 26 regularly spaced monitoring soundings (1 m apart) were selected for the collection of (i) Geonics EM-38 and (ii) Tektronix reflectometer data. Despite the original discrepancies in the EMI and TDR data, we found a significant correlation of the means and standard deviations of the two data series; in particular, after a low-pass spatial filtering of the TDR data. Based on these findings, this paper introduces a novel methodology to calibrate EMI-based electrical conductivities via TDR direct measurements. This

  10. Future flood risk in the tropics as measured by changes in extreme runoff intensity is strongly influenced by plant-physiological responses to rising CO2

    Science.gov (United States)

    Kooperman, G. J.; Hoffman, F. M.; Koven, C.; Lindsay, K. T.; Swann, A. L. S.; Randerson, J. T.

    2017-12-01

    Climate change is expected to increase the frequency of intense flooding events, and thus the risk of flood-related mortality, infrastructure damage, and economic loss. Assessments of future flooding from global climate models based only on precipitation intensity and temperature neglect important processes that occur within the land-surface, particularly the impacts of plant-physiological responses to rising CO2. Higher CO2 reduces stomatal conductance, leading to less water loss through transpiration and higher soil moisture. For a given precipitation rate, higher soil moisture decreases the amount of rainwater that infiltrates the surface and increases runoff. Here we assess the relative impacts of plant-physiological and radiative-greenhouse effects on changes in extreme runoff intensity over tropical continents using the Community Earth System Model. We find that extreme percentile rates increase significantly more than mean runoff in response to higher CO2. Plant-physiological effects contribute to only a small increase in precipitation intensity, but are a dominant driver of runoff intensification, contributing to one-half of the 99th percentile runoff intensity change and one-third of the 99.9th percentile change. Comprehensive assessments of future flooding risk need to account for the physiological as well as radiative impacts of CO2 in order to better inform flood prediction and mitigation practices.

  11. Lifetime measurements in transitional nuclei by fast electronic scintillation timing

    Science.gov (United States)

    Caprio, M. A.; Zamfir, N. V.; Casten, R. F.; Amro, H.; Barton, C. J.; Beausang, C. W.; Cooper, J. R.; Gürdal, G.; Hecht, A. A.; Hutter, C.; Krücken, R.; McCutchan, E. A.; Meyer, D. A.; Novak, J. R.; Pietralla, N.; Ressler, J. J.; Berant, Z.; Brenner, D. S.; Gill, R. L.; Regan, P. H.

    2002-10-01

    A new generation of experiments studying nuclei in spherical-deformed transition regions has been motivated by the introduction of innovative theoretical approaches to the treatment of these nuclei. The important structural signatures in the transition regions, beyond the basic yrast level properties, involve γ-ray transitions between low-spin, non-yrast levels, and so information on γ-ray branching ratios and absolute matrix elements (or level lifetimes) for these transitions is crucial. A fast electronic scintillation timing (FEST) system [H. Mach, R. L. Gill, and M. Moszyński, Nucl. Instrum. Methods A 280, 49 (1989)], making use of BaF2 and plastic scintillation detectors, has been implemented at the Yale Moving Tape Collector for the measurement of lifetimes of states populated in β^ decay. Experiments in the A100 (Pd, Ru) and A150 (Dy, Yb) regions have been carried out, and a few examples will be presented. Supported by the US DOE under grants and contracts DE-FG02-91ER-40609, DE-FG02-88ER-40417, and DE-AC02-98CH10886 and by the German DFG under grant Pi 393/1.

  12. A Feedback Optimal Control Algorithm with Optimal Measurement Time Points

    Directory of Open Access Journals (Sweden)

    Felix Jost

    2017-02-01

    Full Text Available Nonlinear model predictive control has been established as a powerful methodology to provide feedback for dynamic processes over the last decades. In practice it is usually combined with parameter and state estimation techniques, which allows to cope with uncertainty on many levels. To reduce the uncertainty it has also been suggested to include optimal experimental design into the sequential process of estimation and control calculation. Most of the focus so far was on dual control approaches, i.e., on using the controls to simultaneously excite the system dynamics (learning as well as minimizing a given objective (performing. We propose a new algorithm, which sequentially solves robust optimal control, optimal experimental design, state and parameter estimation problems. Thus, we decouple the control and the experimental design problems. This has the advantages that we can analyze the impact of measurement timing (sampling independently, and is practically relevant for applications with either an ethical limitation on system excitation (e.g., chemotherapy treatment or the need for fast feedback. The algorithm shows promising results with a 36% reduction of parameter uncertainties for the Lotka-Volterra fishing benchmark example.

  13. The Rise of Iran

    DEFF Research Database (Denmark)

    Jakobsen, Peter Viggo; Rahigh-Aghsan, Ali

    2010-01-01

    Iran is viewed by many as a rising power that poses an increasing threat to regional and even global security. This view is wrong for three reasons. Iran's hard and soft power is exaggerated by most accounts; it is too limited to allow the Iranians to dominate the Persian Gulf let alone the Middle...... East, and its brand of Shi‘ism has very limited appeal outside of Iran. Second, growing internal political and economic instability will seriously limit Iran's bid for regional dominance. Third, the failure to stop the Iranian nuclear program has led analysts to underestimate the ability of the other...... regional powers and the West to balance Iran and contain its influence, even if it acquires nuclear weapons. If these limitations on Iranian power are taken into account the rise seems destined to be a short one....

  14. Influence of PSA, PSA velocity and PSA doubling time on contrast-enhanced 18F-choline PET/CT detection rate in patients with rising PSA after radical prostatectomy

    International Nuclear Information System (INIS)

    Schillaci, Orazio; Calabria, Ferdinando; Tavolozza, Mario; Caracciolo, Cristiana Ragano; Orlacchio, Antonio; Danieli, Roberta; Simonetti, Giovanni; Agro, Enrico Finazzi; Miano, Roberto

    2012-01-01

    To evaluate the accuracy of contrast-enhanced 18 F-choline PET/CT in restaging patients with prostate cancer after radical prostatectomy in relation to PSA, PSA velocity (PSAve) and PSA doubling time (PSAdt). PET/CT was performed in 49 patients (age range 58-87 years) with rising PSA (mean 4.13 ng/ml) who were divided in four groups according to PSA level: ≤1 ng/ml, 1 to ≤2 ng/ml, 2 to ≤4 ng/ml, and >4 ng/ml. PSAve and PSAdt were measured. PET and CT scans were interpreted separately and then together. PET/CT diagnosed relapse in 33 of the 49 patients (67%). The detection rates were 20%, 55%, 80% and 87% in the PSA groups ≤1, 1 to ≤2, 2 to ≤4 and >4 ng/ml, respectively. PET/CT was positive in 7 of 18 patients (38.9%) with a PSA ≤2 ng/ml, and in 26 of 31 (83.9%) with a PSA >2 ng/ml. PET/CT was positive in 7 of 25 patients (84%) with PSAdt ≤6 months, and in 12 of 24 patients (50%) with PSAdt >6 months, and was positive in 26 of 30 patients (86%) with a PSAve >2 ng/ml per year, and in 7 of 19 patients (36.8%) with PSAve ≤2 ng/ml per year. PET alone was positive in 31 of 49 patients (63.3%), and of these 31 patients, CT was negative in 14 but diagnosed bone lesions in 2 patients in whom PET alone was negative. CT with the administration of intravenous contrast medium did not provide any further information. Detection rate of 18 F-choline imaging is closely related to PSA and PSA kinetics. In particular, 18 F-choline PET/CT is recommended in patients with PSA >2 ng/ml, PSAdt ≤6 months and PSAve >2 ng/ml per year. CT is useful for detecting bone metastases that are not 18 F-choline-avid. The use of intravenous contrast agent seems unnecessary. (orig.)

  15. Influence of PSA, PSA velocity and PSA doubling time on contrast-enhanced {sup 18}F-choline PET/CT detection rate in patients with rising PSA after radical prostatectomy

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Orazio [University ' ' Tor Vergata' ' , Department of Biopathology and Diagnostic Imaging, Interventional, Rome (Italy); IRCCS Neuromed, Department of Nuclear Medicine and Molecular Imaging, Pozzilli (Italy); Calabria, Ferdinando [IRCCS Neuromed, Department of Nuclear Medicine and Molecular Imaging, Pozzilli (Italy); Tavolozza, Mario; Caracciolo, Cristiana Ragano; Orlacchio, Antonio; Danieli, Roberta; Simonetti, Giovanni [University ' ' Tor Vergata' ' , Department of Biopathology and Diagnostic Imaging, Interventional, Rome (Italy); Agro, Enrico Finazzi; Miano, Roberto [University Hospital ' ' Tor Vergata' ' , Department of Urology, Rome (Italy)

    2012-04-15

    To evaluate the accuracy of contrast-enhanced {sup 18}F-choline PET/CT in restaging patients with prostate cancer after radical prostatectomy in relation to PSA, PSA velocity (PSAve) and PSA doubling time (PSAdt). PET/CT was performed in 49 patients (age range 58-87 years) with rising PSA (mean 4.13 ng/ml) who were divided in four groups according to PSA level: {<=}1 ng/ml, 1 to {<=}2 ng/ml, 2 to {<=}4 ng/ml, and >4 ng/ml. PSAve and PSAdt were measured. PET and CT scans were interpreted separately and then together. PET/CT diagnosed relapse in 33 of the 49 patients (67%). The detection rates were 20%, 55%, 80% and 87% in the PSA groups {<=}1, 1 to {<=}2, 2 to {<=}4 and >4 ng/ml, respectively. PET/CT was positive in 7 of 18 patients (38.9%) with a PSA {<=}2 ng/ml, and in 26 of 31 (83.9%) with a PSA >2 ng/ml. PET/CT was positive in 7 of 25 patients (84%) with PSAdt {<=}6 months, and in 12 of 24 patients (50%) with PSAdt >6 months, and was positive in 26 of 30 patients (86%) with a PSAve >2 ng/ml per year, and in 7 of 19 patients (36.8%) with PSAve {<=}2 ng/ml per year. PET alone was positive in 31 of 49 patients (63.3%), and of these 31 patients, CT was negative in 14 but diagnosed bone lesions in 2 patients in whom PET alone was negative. CT with the administration of intravenous contrast medium did not provide any further information. Detection rate of {sup 18}F-choline imaging is closely related to PSA and PSA kinetics. In particular, {sup 18}F-choline PET/CT is recommended in patients with PSA >2 ng/ml, PSAdt {<=}6 months and PSAve >2 ng/ml per year. CT is useful for detecting bone metastases that are not {sup 18}F-choline-avid. The use of intravenous contrast agent seems unnecessary. (orig.)

  16. The rise and rise of alternative medicine

    OpenAIRE

    Cauchi, Maurice N.

    2011-01-01

    Before scientific medicine appeared on the scene less than 200 years ago, alternative medicine existed side by side with what was considered to be college-certified medical practice. Surgery took a bit longer to become an academic discipline, looked down on by medical doctors and was, for a long time restricted to unqualified barbers. Since then, with the application of the scientific method, medicine has made, and is still making enormous strides. We do no...

  17. High time resolution measurements of the thermosphere from Fabry-Perot Interferometer measurements of atomic oxygen

    Directory of Open Access Journals (Sweden)

    E. A. K. Ford

    2007-06-01

    Full Text Available Recent advances in the performance of CCD detectors have enabled a high time resolution study of the high latitude upper thermosphere with Fabry-Perot Interferometers (FPIs to be performed. 10-s integration times were used during a campaign in April 2004 on an FPI located in northern Sweden in the auroral oval. The FPI is used to study the thermosphere by measuring the oxygen red line emission at 630.0 nm, which emits at an altitude of approximately 240 km. Previous time resolutions have been 4 min at best, due to the cycle of look directions normally observed. By using 10 s rather than 40 s integration times, and by limiting the number of full cycles in a night, high resolution measurements down to 15 s were achievable. This has allowed the maximum variability of the thermospheric winds and temperatures, and 630.0 nm emission intensities, at approximately 240 km, to be determined as a few minutes. This is a significantly greater variability than the often assumed value of 1 h or more. A Lomb-Scargle analysis of this data has shown evidence of gravity wave activity with waves with short periods. Gravity waves are an important feature of mesosphere-lower thermosphere (MLT dynamics, observed using many techniques and providing an important mechanism for energy transfer between atmospheric regions. At high latitudes gravity waves may be generated in-situ by localised auroral activity. Short period waves were detected in all four clear nights when this experiment was performed, in 630.0 nm intensities and thermospheric winds and temperatures. Waves with many periodicities were observed, from periods of several hours, down to 14 min. These waves were seen in all parameters over several nights, implying that this variability is a typical property of the thermosphere.

  18. The timing of scour and fill in a gravel-bedded river measured with buried accelerometers

    Science.gov (United States)

    Gendaszek, Andrew S.; Magirl, Christopher S.; Czuba, Christiana R.; Konrad, Christopher P.

    2013-01-01

    A device that measures the timing of streambed scour and the duration of sediment mobilization at specific depths of a streambed was developed using data-logging accelerometers placed within the gravel substrate of the Cedar River, Washington, USA. Each accelerometer recorded its orientation every 20 min and remained stable until the surrounding gravel matrix mobilized as sediment was transported downstream and scour reached the level of the accelerometer. The accelerometer scour monitors were deployed at 26 locations in salmon-spawning habitat during the 2010–2011 flood season to record when the streambed was scoured to the depth of typical egg-pocket deposition. Scour was recorded at one location during a moderate high-flow event (65 m3/s; 1.25–1.5-year recurrence interval) and at 17 locations during a larger high-flow event (159 m3/s; 7-year recurrence interval). Accelerometer scour monitors recorded periods of intermittent sediment mobilization and stability within a high-flow event providing insight into the duration of scour. Most scour was recorded during the rising limb and at the peak of a flood hydrograph, though some scour occurred during sustained high flows following the peak of the flood hydrograph.

  19. Correlates of objectively measured sedentary time and self-reported screen time in Canadian children.

    Science.gov (United States)

    LeBlanc, Allana G; Broyles, Stephanie T; Chaput, Jean-Philippe; Leduc, Geneviève; Boyer, Charles; Borghese, Michael M; Tremblay, Mark S

    2015-03-18

    Demographic, family, and home characteristics play an important role in determining childhood sedentary behaviour. The objective of this paper was to identify correlates of total sedentary time (SED) and correlates of self-reported screen time (ST) in Canadian children. Child- and parent-reported household, socio-demographic, behavioural, and diet related data were collected; directly measured anthropometric and accelerometer data were also collected for each child. Participants with complete demographic, anthropometric, and either SED (n=524, 41% boys) or ST (n=567, 42% boys) data from the Canadian site of the International Study of Childhood Obesity Lifestyle and the Environment (ISCOLE) were included in analysis. Sixteen potential correlates of SED and ST were examined using multilevel general linear models, adjusting for sex, ethnicity, number of siblings, and socio-economic status. All explanatory variables moderately associated (peducation, and unhealthy eating pattern score and negatively associated with healthy eating pattern score, and weekend breakfast consumption. Few common correlates existed between boys and girls. Several factors were identified as correlates of SED and/or of ST in Canadian children; however, few correlates were common for both SED and ST, and for both boys and girls. This suggests that a single strategy to reduce SED and ST is unlikely to be effective. Future work should examine a variety of other, non-screen based sedentary behaviours and their potential correlates in the hopes of creating tailored public health messages to reduce SED and ST in both boys, and girls.

  20. Real time wave measurements and wave hindcasting in deep waters

    Digital Repository Service at National Institute of Oceanography (India)

    Anand, N.M.; Mandal, S.; SanilKumar, V.; Nayak, B.U.

    Deep water waves off Karwar (lat. 14~'45.1'N, long. 73~'34.8'E) at 75 m water depth pertaining to peak monsoon period have been measured using a Datawell waverider buoy. Measured wave data show that the significant wave height (Hs) predominantly...

  1. Peculiarity of the FEU-85 photomultiplier use for time measurements

    International Nuclear Information System (INIS)

    Akimov, D.Yu.; Samojlenko, V.T.

    1983-01-01

    Regime of the PM-85 operation, ensuring high time resolution with the minimum effects of prepulses, has been described. Zonal characteristics of photocathode as to delay of response and amplitude of signal are presented. Elimination of periphery region of the photocathode PM-85 permits to improve time resolution of scintillation detector. Time characteristics of the detector with plastic scintillator dimensions 24x8x0.5 cm are given

  2. Mixed butanols addition to gasoline surrogates: Shock tube ignition delay time measurements and chemical kinetic modeling

    KAUST Repository

    AlRamadan, Abdullah S.

    2015-10-01

    The demand for fuels with high anti-knock quality has historically been rising, and will continue to increase with the development of downsized and turbocharged spark-ignition engines. Butanol isomers, such as 2-butanol and tert-butanol, have high octane ratings (RON of 105 and 107, respectively), and thus mixed butanols (68.8% by volume of 2-butanol and 31.2% by volume of tert-butanol) can be added to the conventional petroleum-derived gasoline fuels to improve octane performance. In the present work, the effect of mixed butanols addition to gasoline surrogates has been investigated in a high-pressure shock tube facility. The ignition delay times of mixed butanols stoichiometric mixtures were measured at 20 and 40bar over a temperature range of 800-1200K. Next, 10vol% and 20vol% of mixed butanols (MB) were blended with two different toluene/n-heptane/iso-octane (TPRF) fuel blends having octane ratings of RON 90/MON 81.7 and RON 84.6/MON 79.3. These MB/TPRF mixtures were investigated in the shock tube conditions similar to those mentioned above. A chemical kinetic model was developed to simulate the low- and high-temperature oxidation of mixed butanols and MB/TPRF blends. The proposed model is in good agreement with the experimental data with some deviations at low temperatures. The effect of mixed butanols addition to TPRFs is marginal when examining the ignition delay times at high temperatures. However, when extended to lower temperatures (T < 850K), the model shows that the mixed butanols addition to TPRFs causes the ignition delay times to increase and hence behaves like an octane booster at engine-like conditions. © 2015 The Combustion Institute.

  3. Optical measurement of water over-heating in contact with a wall submitted to a quick temperature rise under atmospheric pressure

    International Nuclear Information System (INIS)

    Ebrardt, Jacques

    1981-01-01

    As a technique is necessary for the instantaneous measurement of a liquid temperature at the immediate vicinity of a wall submitted to a quick unsteady heating, this research thesis reports the development of such a technique, and its use for the determination of the temperature reached by the liquid before boiling in unsteady regime. After a report of a literature survey on the unsteady heating of liquid (by thermal shock or progressive heating), and on various theoretical aspects, the author reports the use of a measurement installation which is based on the use of optical interferometry, and on the exploitation of raw experimental data. Results of overheating at boiling initiation are interpreted [fr

  4. Proper-time resolution function for measurement of time evolution of B mesons at the KEK B-Factory

    International Nuclear Information System (INIS)

    Tajima, H.; Aihara, H.; Higuchi, T.; Kawai, H.; Nakadaira, T.; Tanaka, J.; Tomura, T.; Yokoyama, M.; Hazumi, M.; Sakai, Y.; Sumisawa, K.; Kawasaki, T.

    2004-01-01

    The proper-time resolution function for the measurement of the time evolution of B mesons with the Belle detector at KEKB is studied in detail. The obtained resolution function is applied to the measurement of B meson lifetimes, the B0B-bar 0 oscillation frequency and time-dependent CP asymmetries

  5. Global real-time dose measurements using the Automated Radiation Measurements for Aerospace Safety (ARMAS) system

    Science.gov (United States)

    Tobiska, W. Kent; Bouwer, D.; Smart, D.; Shea, M.; Bailey, J.; Didkovsky, L.; Judge, K.; Garrett, H.; Atwell, W.; Gersey, B.; Wilkins, R.; Rice, D.; Schunk, R.; Bell, D.; Mertens, C.; Xu, X.; Wiltberger, M.; Wiley, S.; Teets, E.; Jones, B.; Hong, S.; Yoon, K.

    2016-11-01

    The Automated Radiation Measurements for Aerospace Safety (ARMAS) program has successfully deployed a fleet of six instruments measuring the ambient radiation environment at commercial aircraft altitudes. ARMAS transmits real-time data to the ground and provides quality, tissue-relevant ambient dose equivalent rates with 5 min latency for dose rates on 213 flights up to 17.3 km (56,700 ft). We show five cases from different aircraft; the source particles are dominated by galactic cosmic rays but include particle fluxes for minor radiation periods and geomagnetically disturbed conditions. The measurements from 2013 to 2016 do not cover a period of time to quantify galactic cosmic rays' dependence on solar cycle variation and their effect on aviation radiation. However, we report on small radiation "clouds" in specific magnetic latitude regions and note that active geomagnetic, variable space weather conditions may sufficiently modify the magnetospheric magnetic field that can enhance the radiation environment, particularly at high altitudes and middle to high latitudes. When there is no significant space weather, high-latitude flights produce a dose rate analogous to a chest X-ray every 12.5 h, every 25 h for midlatitudes, and every 100 h for equatorial latitudes at typical commercial flight altitudes of 37,000 ft ( 11 km). The dose rate doubles every 2 km altitude increase, suggesting a radiation event management strategy for pilots or air traffic control; i.e., where event-driven radiation regions can be identified, they can be treated like volcanic ash clouds to achieve radiation safety goals with slightly lower flight altitudes or more equatorial flight paths.

  6. Measurements of spatial population synchrony: influence of time series transformations.

    Science.gov (United States)

    Chevalier, Mathieu; Laffaille, Pascal; Ferdy, Jean-Baptiste; Grenouillet, Gaël

    2015-09-01

    Two mechanisms have been proposed to explain spatial population synchrony: dispersal among populations, and the spatial correlation of density-independent factors (the "Moran effect"). To identify which of these two mechanisms is driving spatial population synchrony, time series transformations (TSTs) of abundance data have been used to remove the signature of one mechanism, and highlight the effect of the other. However, several issues with TSTs remain, and to date no consensus has emerged about how population time series should be handled in synchrony studies. Here, by using 3131 time series involving 34 fish species found in French rivers, we computed several metrics commonly used in synchrony studies to determine whether a large-scale climatic factor (temperature) influenced fish population dynamics at the regional scale, and to test the effect of three commonly used TSTs (detrending, prewhitening and a combination of both) on these metrics. We also tested whether the influence of TSTs on time series and population synchrony levels was related to the features of the time series using both empirical and simulated time series. For several species, and regardless of the TST used, we evidenced a Moran effect on freshwater fish populations. However, these results were globally biased downward by TSTs which reduced our ability to detect significant signals. Depending on the species and the features of the time series, we found that TSTs could lead to contradictory results, regardless of the metric considered. Finally, we suggest guidelines on how population time series should be processed in synchrony studies.

  7. Correlation measure to detect time series distances, whence economy globalization

    Science.gov (United States)

    Miśkiewicz, Janusz; Ausloos, Marcel

    2008-11-01

    An instantaneous time series distance is defined through the equal time correlation coefficient. The idea is applied to the Gross Domestic Product (GDP) yearly increments of 21 rich countries between 1950 and 2005 in order to test the process of economic globalisation. Some data discussion is first presented to decide what (EKS, GK, or derived) GDP series should be studied. Distances are then calculated from the correlation coefficient values between pairs of series. The role of time averaging of the distances over finite size windows is discussed. Three network structures are next constructed based on the hierarchy of distances. It is shown that the mean distance between the most developed countries on several networks actually decreases in time, -which we consider as a proof of globalization. An empirical law is found for the evolution after 1990, similar to that found in flux creep. The optimal observation time window size is found ≃15 years.

  8. Measurement and control of cement set times in waste solidification

    International Nuclear Information System (INIS)

    Stone, J.A.; d'Entremont, P.D.

    1976-09-01

    Fixation of radioactive waste in concrete was investigated on laboratory scale. Some cement formulations containing simulated or actual sludges from the Savannah River Plant had set times that would be too short for reliable handling in plant equipment. Set times could be controlled by use of excess water, but the concrete forms produced had inferior strength. A commercial organic retarder was found to be effective for increasing set times of cement-sludge formulations. However, the dosage of retarder required to control set times of high-alumina cement formulations was 1.0 to 1.5 wt percent of dry solids, which is 5 to 10 times the normal dosage for Portland cements. Data were obtained to predict the optimum content of retarder and water

  9. Time-of-flight neutron spectra measurements in Zenith

    Energy Technology Data Exchange (ETDEWEB)

    Barclay, F R; Coates, M S; Diment, K M; Durrani, S A; Gayther, D B; Poole, M J; Reed, D L

    1962-01-15

    Neutron spectra in the second core loading of ZENITH have been measured using a neutron chopper. Spectra at two positions in the reactore core were obtained over a range of temperatures extending to 650 deg C.

  10. Time-of-Flight Measurement of Sound Speed in Air

    Science.gov (United States)

    Ganci, Salvatore

    2011-01-01

    This paper describes a set of simple experiments with a very low cost using a notebook as a measuring instrument without external hardware. The major purpose is to provide demonstration experiments for schools with very low budgets. (Contains 6 figures.)

  11. Inertial rise of a meniscus on a vertical cylinder

    KAUST Repository

    O’Kiely, Doireann

    2015-03-03

    © © 2015 Cambridge University PressA. We consider the inertia-dominated rise of a meniscus around a vertical circular cylinder. Previous experiments and scaling analysis suggest that the height of the meniscus, h-{m}, grows with the time following the initiation of rise, t, like h-{m}\\\\propto t^{1/2}. This is in contrast to the rise on a vertical plate, which obeys the classic capillary-inertia scaling h-{m}\\\\propto t^{2/3}. We highlight a subtlety in the scaling analysis that yielded h-{m}\\\\propto t^{1/2} and investigate the consequences of this subtlety. We develop a potential flow model of the dynamic problem, which we solve using the finite element method. Our numerical results agree well with previous experiments but suggest that the correct early time behaviour is, in fact, h-{m}\\\\propto t^{2/3}. Furthermore, we show that at intermediate times the dynamic rise of the meniscus is governed by two parameters: the contact angle and the cylinder radius measured relative to the capillary length scale, t^{2/3}. This result allows us to collapse previous experimental results with different cylinder radii (but similar static contact angles) onto a single master curve.

  12. Measurement and evaluation of transit travel time reliability

    Science.gov (United States)

    2011-01-01

    Transportation system customers need consistency in their daily travel times to enable them to plan their daily : activities, whether that is a commuter on their way to work, a company setting up delivery schedules for justintime : manufacturin...

  13. Bluetooth-based travel time/speed measuring systems development.

    Science.gov (United States)

    2010-06-01

    Agencies in the Houston region have traditionally used toll tag readers to provide travel times on : freeways and High Occupancy Vehicle (HOV) lanes, but these systems require large amounts of costly and : physically invasive infrastructure. Bluetoot...

  14. Real-time precision measuring device of tree diameter growth

    Science.gov (United States)

    Guo, Mingming; Chen, Aijun; Li, Dongsheng; Liu, Nan; Yao, Jingyuan

    2016-01-01

    DBH(diameter at breast height) is an important factor to reflect of the quality of plant growth, also an important parameter indispensable in forest resources inventory and forest carbon sink, the accurate measurement of DBH or not is directly related to the research of forest resources inventory and forest carbon sink. In this paper, the principle and the mathematical model of DBH measurement device were introduced, the fixture measuring device and the hardware circuit for this tree diameter were designed, the measurement software programs were compiled, and the precision measuring device of tree diameter growth was developed. Some experiments with Australia fir were conducted. Based on experiment data, the correlations among the DBH variation of Australian fir, the environment temperature, air humility and PAR(photosynthetically active radiation) were obtained. The effects of environmental parameters (environment temperature, air humility and PAR) on tree diameter were analyzed. Experimental results show that there is a positive correlation between DBH variation of Australian fir and environment temperature, a negative correlation between DBH variation of Australian fir and air humility , so is PAR.

  15. Real-Time Measurements for Adaptive and Cognitive Radio Systems

    Directory of Open Access Journals (Sweden)

    Hüseyin Arslan

    2009-01-01

    Full Text Available Adaptive and cognitive radios (CR have been becoming popular for optimizing mobile radio system transmission and reception. One of the most important elements of the adaptive radio and CR concepts is the ability to measure, sense, learn about, and be aware of parameters related to the radio channel characteristics, availability of spectrum and power, interference and noise temperature, operational environment of radio, user requirements and applications, available networks and infrastructures, local policies, other operating restrictions, and so on. This paper discusses some of the important measurement parameters for enabling adaptive radio and CR systems along with their relationships and impacts on the performance including relevant challenges.

  16. Comparison of real-time instruments and gravimetric method when measuring particulate matter in a residential building.

    Science.gov (United States)

    Wang, Zuocheng; Calderón, Leonardo; Patton, Allison P; Sorensen Allacci, MaryAnn; Senick, Jennifer; Wener, Richard; Andrews, Clinton J; Mainelis, Gediminas

    2016-11-01

    This study used several real-time and filter-based aerosol instruments to measure PM 2.5 levels in a high-rise residential green building in the Northeastern US and compared performance of those instruments. PM 2.5 24-hr average concentrations were determined using a Personal Modular Impactor (PMI) with 2.5 µm cut (SKC Inc., Eighty Four, PA) and a direct reading pDR-1500 (Thermo Scientific, Franklin, MA) as well as its filter. 1-hr average PM 2.5 concentrations were measured in the same apartments with an Aerotrak Optical Particle Counter (OPC) (model 8220, TSI, Inc., Shoreview, MN) and a DustTrak DRX mass monitor (model 8534, TSI, Inc., Shoreview, MN). OPC and DRX measurements were compared with concurrent 1-hr mass concentration from the pDR-1500. The pDR-1500 direct reading showed approximately 40% higher particle mass concentration compared to its own filter (n = 41), and 25% higher PM 2.5 mass concentration compared to the PMI 2.5 filter. The pDR-1500 direct reading and PMI 2.5 in non-smoking homes (self-reported) were not significantly different (n = 10, R 2 = 0.937), while the difference between measurements for smoking homes was 44% (n = 31, R 2 = 0.773). Both OPC and DRX data had substantial and significant systematic and proportional biases compared with pDR-1500 readings. However, these methods were highly correlated: R 2 = 0.936 for OPC versus pDR-1500 reading and R 2 = 0.863 for DRX versus pDR-1500 reading. The data suggest that accuracy of aerosol mass concentrations from direct-reading instruments in indoor environments depends on the instrument, and that correction factors can be used to reduce biases of these real-time monitors in residential green buildings with similar aerosol properties. This study used several real-time and filter-based aerosol instruments to measure PM 2.5 levels in a high-rise residential green building in the northeastern United States and compared performance of those instruments. The data show that while the use of real-time

  17. Dielectric-wall linear accelerator with a high voltage fast rise time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators

    Science.gov (United States)

    Caporaso, George J.; Sampayan, Stephen E.; Kirbie, Hugh C.

    1998-01-01

    A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface.

  18. Time response measurements of pressure sensors using pink noise technique

    International Nuclear Information System (INIS)

    Pereira, Iraci Martinez; Santos, Roberto Carlos dos

    2009-01-01

    This work presents an experimental setup for Pink Noise method application on pressure transmitters' response times. The Pink Noise method consists on injecting artificial pressure noise into the pressure transmitter. The artificial pressure noise is generated using a current-to-pressure (I-to-P) converter, which is driven by a random noise signal generator. The output pressure transmitter noise is then analyzed using conventional Noise Analysis Technique. Noise signals may be interpreted using spectral techniques or empirical time series models. The frequency domain method consists of evaluating the Power Spectral Density (PSD) function. The information needed for time constant estimation can be obtained by fitting an all-pole transfer function to this power spectral density. (author)

  19. Centrality measures in temporal networks with time series analysis

    Science.gov (United States)

    Huang, Qiangjuan; Zhao, Chengli; Zhang, Xue; Wang, Xiaojie; Yi, Dongyun

    2017-05-01

    The study of identifying important nodes in networks has a wide application in different fields. However, the current researches are mostly based on static or aggregated networks. Recently, the increasing attention to networks with time-varying structure promotes the study of node centrality in temporal networks. In this paper, we define a supra-evolution matrix to depict the temporal network structure. With using of the time series analysis, the relationships between different time layers can be learned automatically. Based on the special form of the supra-evolution matrix, the eigenvector centrality calculating problem is turned into the calculation of eigenvectors of several low-dimensional matrices through iteration, which effectively reduces the computational complexity. Experiments are carried out on two real-world temporal networks, Enron email communication network and DBLP co-authorship network, the results of which show that our method is more efficient at discovering the important nodes than the common aggregating method.

  20. Measuring Passenger Travel Time Reliability Using Smart Card Data

    NARCIS (Netherlands)

    Bagherian, M.; Cats, O.; van Oort, N.; Hickman, M

    2016-01-01

    Service reliability is a key performance measure for transit agencies in increasing their service quality and thus ridership. Conventional reliability metrics are established based on vehicle movements and thus do not adequately reflect passenger’s experience. In the past few years, the growing

  1. Methodological Issues in Measures of Imitative Reaction Times

    Science.gov (United States)

    Aicken, Michael D.; Wilson, Andrew D.; Williams, Justin H. G.; Mon-Williams, Mark

    2007-01-01

    Ideomotor (IM) theory suggests that observing someone else perform an action activates an internal motor representation of that behaviour within the observer. Evidence supporting the case for an ideomotor theory of imitation has come from studies that show imitative responses to be faster than the same behavioural measures performed in response to…

  2. Pharyngeal transit time measured by scintigraphic and biomagnetic method

    International Nuclear Information System (INIS)

    Miquelin, C.A.; Braga, F.J.H.N.; Baffa, O.

    1996-01-01

    A comparative evaluation between scintigraphic and biomagnetic method to measure the pharyngeal transit is presented. Three volunteers have been studied. The aliment (yogurt) was labeled with 9 9 m Technetium for the scintigraphic test and with ferrite for the biomagnetic one. The preliminary results indicate a difference between the values obtained, probably due to the biomagnetic detector resolution

  3. Measuring Passenger Travel Time Reliability using Smartcard Data

    NARCIS (Netherlands)

    Bagherian, M.; Cats, O.; van Oort, N.; Hickman, M

    2016-01-01

    Service reliability is a key performance measure for transit agencies in increasing their service quality and thus ridership. Conventional reliability metrics are established based on vehicle movements and thus do not adequately reflect passenger’s experience. In the past few years, the growing

  4. Simplified scintigraphic methods for measuring gastrointestinal transit times

    DEFF Research Database (Denmark)

    Graff, J; Brinch, K; Madsen, Jan Lysgård

    2000-01-01

    . After ingestion of a meal containing 111indium-labelled water and 99mtechnetium-labelled omelette, imaging was performed at intervals of 30 min until all radioactivity was located in the colon and henceforth at intervals of 24 h until all radioactivity had cleared from the colon. Gastric, small...... intestinal and colonic mean transit times were calculated for both markers and compared with fractional gastric emptying at 2 h, fractional colonic filling at 4 h, and geometric centre of colonic content at 24 h, respectively. Highly significant correlations were found between gastric mean transit time...... and fractional gastric emptying at 2 h (111In: r=0.95, P

  5. The rise of Chrome

    Directory of Open Access Journals (Sweden)

    Jonathan Tamary

    2015-10-01

    Full Text Available Since Chrome’s initial release in 2008 it has grown in market share, and now controls roughly half of the desktop browsers market. In contrast with Internet Explorer, the previous dominant browser, this was not achieved by marketing practices such as bundling the browser with a pre-loaded operating system. This raises the question of how Chrome achieved this remarkable feat, while other browsers such as Firefox and Opera were left behind. We show that both the performance of Chrome and its conformance with relevant standards are typically better than those of the two main contending browsers, Internet Explorer and Firefox. In addition, based on a survey of the importance of 25 major features, Chrome product managers seem to have made somewhat better decisions in selecting where to put effort. Thus the rise of Chrome is consistent with technical superiority over the competition.

  6. Was the economic crisis 1997-1998 responsible for rising suicide rates in East/Southeast Asia? A time-trend analysis for Japan, Hong Kong, South Korea, Taiwan, Singapore and Thailand.

    Science.gov (United States)

    Chang, Shu-Sen; Gunnell, David; Sterne, Jonathan A C; Lu, Tsung-Hsueh; Cheng, Andrew T A

    2009-04-01

    In 1997-1998 a widespread economic crisis hit the economies of many East/Southeast Asian countries; its impact on suicide rates across the region has not been systematically documented. We investigated the impact of the Asian economic crisis (1997-1998) on suicide in Japan, Hong Kong, South Korea, Taiwan, Singapore and Thailand. Suicide and population data for the period 1985-2006 were extracted from the World Health Organisation's mortality database and Taiwanese mortality statistics. Sex-specific age-standardised suicide rates for people aged 15years or above were analysed using joinpoint regression. Trends in divorce, marriage, unemployment, gross domestic product (GDP) per capita and alcohol consumption were compared with trends in suicide rates graphically and using time-series analysis. Suicide mortality decreased in the late 1980s and early 1990s but subsequently increased markedly in all countries except Singapore, which had steadily declining suicide rates throughout the study period. Compared to 1997, male rates in 1998 rose by 39% in Japan, 44% in Hong Kong and 45% in Korea; rises in female rates were less marked. Male rates also rose in Thailand, but accurate data were incomplete. The economic crisis was associated with 10,400 more suicides in 1998 compared to 1997 in Japan, Hong Kong and Korea. Similar increases in suicide rates were not seen in Taiwan and Singapore, the two countries where the economic crisis had a smaller impact on GDP and unemployment. Time-series analyses indicated that some of the crisis's impact on male suicides was attributable to increases in unemployment. These findings suggest an association of the Asian economic crisis with a sharp increase in suicide mortality in some, but not all, East/Southeast Asian countries, and that these increases were most closely associated with rises in unemployment.

  7. Time Series Factor Analysis with an Application to Measuring Money

    NARCIS (Netherlands)

    Gilbert, Paul D.; Meijer, Erik

    2005-01-01

    Time series factor analysis (TSFA) and its associated statistical theory is developed. Unlike dynamic factor analysis (DFA), TSFA obviates the need for explicitly modeling the process dynamics of the underlying phenomena. It also differs from standard factor analysis (FA) in important respects: the

  8. PART-TIME WORK AS A PRE-RETIREMENT MEASURE

    CERN Document Server

    Human Resources Division

    2001-01-01

    Upon the proposal of the Standing Concertation Committee at its meeting on 9 and 10 October 2001, the Director-General has approved the extension of this part-time work scheme for requested effective dates commencing not later than 1 January 2003.

  9. Measuring time-dependent deformations in metallic MEMS

    NARCIS (Netherlands)

    Bergers, L.I.J.C.; Hoefnagels, J.P.M.; Delhey, N.K.R.; Geers, M.G.D.

    2011-01-01

    The reliability of metallic microelectromechanical systems (MEMS) depends on time-dependent deformation such as creep. Key to this process is the interaction between microstructural length scales and dimensional length scales, so-called size-effects. As a first critical step towards studying these

  10. Measurement of informal care: an empirical study into the valid measurement of time spent on informal caregiving.

    NARCIS (Netherlands)

    Berg, Bernard van den; Spauwen, Pol

    2006-01-01

    The incorporation of informal care into economic evaluations of health care is troublesome. The debate focuses on the valuation of time spent on informal caregiving, while time measurement, a related and may be even a more important issue, tends to be neglected. Valid time measurement is a necessary

  11. Quality Measures for Dialysis: Time for a Balanced Scorecard.

    Science.gov (United States)

    Kliger, Alan S

    2016-02-05

    Recent federal legislation establishes a merit-based incentive payment system for physicians, with a scorecard for each professional. The Centers for Medicare and Medicaid Services evaluate quality of care with clinical performance measures and have used these metrics for public reporting and payment to dialysis facilities. Similar metrics may be used for the future merit-based incentive payment system. In nephrology, most clinical performance measures measure processes and intermediate outcomes of care. These metrics were developed from population studies of best practice and do not identify opportunities for individualizing care on the basis of patient characteristics and individual goals of treatment. The In-Center Hemodialysis (ICH) Consumer Assessment of Healthcare Providers and Systems (CAHPS) survey examines patients' perception of care and has entered the arena to evaluate quality of care. A balanced scorecard of quality performance should include three elements: population-based best clinical practice, patient perceptions, and individually crafted patient goals of care. Copyright © 2016 by the American Society of Nephrology.

  12. Time-resolved temperature measurements in a rapid compression machine using quantum cascade laser absorption in the intrapulse mode

    KAUST Repository

    Nasir, Ehson Fawad

    2016-07-16

    A temperature sensor based on the intrapulse absorption spectroscopy technique has been developed to measure in situ temperature time-histories in a rapid compression machine (RCM). Two quantum-cascade lasers (QCLs) emitting near 4.55μm and 4.89μm were operated in pulsed mode, causing a frequency "down-chirp" across two ro-vibrational transitions of carbon monoxide. The down-chirp phenomenon resulted in large spectral tuning (δν ∼2.8cm-1) within a single pulse of each laser at a high pulse repetition frequency (100kHz). The wide tuning range allowed the application of the two-line thermometry technique, thus making the sensor quantitative and calibration-free. The sensor was first tested in non-reactive CO-N2 gas mixtures in the RCM and then applied to cases of n-pentane oxidation. Experiments were carried out for end of compression (EOC) pressures and temperatures ranging 9.21-15.32bar and 745-827K, respectively. Measured EOC temperatures agreed with isentropic calculations within 5%. Temperature rise measured during the first-stage ignition of n-pentane is over-predicted by zero-dimensional kinetic simulations. This work presents, for the first time, highly time-resolved temperature measurements in reactive and non-reactive rapid compression machine experiments. © 2016 Elsevier Ltd.

  13. Quantum limit on time measurement in a gravitational field

    International Nuclear Information System (INIS)

    Sinha, Supurna; Samuel, Joseph

    2015-01-01

    Good clocks are of importance both to fundamental physics and for applications in astronomy, metrology and global positioning systems. In a recent technological breakthrough, researchers at NIST have been able to achieve a stability of one part in 10 18 using an ytterbium clock. This naturally raises the question of whether there are fundamental limits to time keeping. In this article we point out that gravity and quantum mechanics set a fundamental limit on the fractional frequency uncertainty of clocks. This limit comes from a combination of the uncertainty relation, the gravitational redshift and the relativistic time dilation effect. For example, a single ion aluminium clock in a terrestrial gravitational field cannot achieve a fractional frequency uncertainty better than one part in 10 22 . This fundamental limit explores the interaction between gravity and quantum mechanics on a laboratory scale. (paper)

  14. In situ response time measurements of RTD temperature sensors

    International Nuclear Information System (INIS)

    Goncalves, I.M.P.

    1985-01-01

    The loop-current-step-response test provides a mean for determining the time constant of resistence thermometers. The test consist in heating the sensor a few degrees above ambient temperature by causing a step pertubation in the electric current that flows through the sensor leads. The developed mathematical transformation permits to use data collected during the internal heating transient to predict the sensor response to perturbations in fluid temperature. Experimental data obtained show that the time constant determined by method is within 15 percent of true value. The loop-current-step-response test is a remote in situ test, which can be performed with the sensor installed in the process. Consequently it takes account the local heat transfer conditions, and appropriated for nuclear power plants, where sensors are installed in points of difficult access. (author) [pt

  15. Opportunities for measuring DNA synthesis time by quantitative autoradiography

    International Nuclear Information System (INIS)

    Vasileva, D.

    1980-01-01

    DNA sysntesis time (Tsub(s)) in cells of the canine erythropoiesis and myelopoiesis pools was determined by quantitative autoradiography according to Doermer. In contrast to mitosis labelling for Tsub(s) estimation as so far applied, this technique uses well-differentiated cells. After blocking endogeneous DNA synthesis with 5-fluorodeoxyuridine, its further course becomes dependent on exogeneous supply of thymidine, in the form of 14 C-thymidine. From incroporation of the latter into the individual cell within a definite time span (3-7 min) and taking into account its total amount, Tsub(s) may be calculated. The data thus obtained were found to agree with Tsub(s) values as estimated from the labelled mitosis curve

  16. Measuring the Rate of Change in Sea Level and Its Adherence to USACE Sea Level Rise Planning Scenarios Using Timeseries Metrics

    Science.gov (United States)

    White, K. D.; Huang, N.; Huber, M.; Veatch, W.; Moritz, H.; Obrien, P. S.; Friedman, D.

    2017-12-01

    In 2013, the United States Army Corps of Engineers (USACE) issued guidance for all Civil Works activities to incorporate the effects of sea level change as described in three distinct planning scenarios.[1] These planning scenarios provided a useful framework to incorporate these effects into Civil Works activities, but required the manual calculation of these scenarios for a given gage and set of datum. To address this need, USACE developed the Sea Level Change Curve Calculator (SLCCC) in 2014 which provided a "simple, web-based tool to provide repeatable analytical results."[2]USACE has been developing a successor to the SLCCC application which retains the same, intuitive functionality to calculate these planning scenarios, but it also allows the comparison of actual sea level change between 1992 and today against the projections, and builds on the user's ability to understand the rate of change using a variety of timeseries metrics (e.g. moving averages, trends) and related visualizations. These new metrics help both illustrate and measure the complexity and nuances of sea level change. [1] ER 1000-2-8162. http://www.publications.usace.army.mil/Portals/76/Publications/EngineerRegulations/ER_1100-2-8162.pdf. [2] SLCC Manual. http://www.corpsclimate.us/docs/SLC_Calculator_Manual_2014_88.pdf.

  17. Continuous radon measurements in schools: time variations and related parameters

    International Nuclear Information System (INIS)

    Giovani, C.; Cappelletto, C.; Garavaglia, M.; Pividore, S.; Villalta, R.

    2004-01-01

    Some results are reported of observations made within a four-year survey, during different seasons and in different conditions of school building use. Natural radon variations (day-night cycles, seasonal and temperature dependent variations etc..) and artificial ones (opening of windows, weekends and vacations, deployment of air conditioning or heating systems. etc.) were investigated as parameters affecting time dependent radon concentrations. (P.A.)

  18. Microreactortechnology: Real-Time Flow Measurements in Organic Synthesis

    Directory of Open Access Journals (Sweden)

    Pieter J. Nieuwland

    2012-03-01

    Full Text Available With the commercial availability of integrated microreactor systems, the numbers of chemical processes that are performed nowadays in a continuous flow is growing rapidly. The control over mixing efficiency and homogeneous heating in these reactors allows industrial scale production that was often hampered by the use of large amounts of hazardous chemicals. Accurate actuation and in line measurements of the flows, to have a better control over the chemical reaction, is of added value for increasing reproducibility and a safe production.

  19. Time measurements with a mobile device using sound

    Science.gov (United States)

    Wisman, Raymond F.; Spahn, Gabriel; Forinash, Kyle

    2018-05-01

    Data collection is a fundamental skill in science education, one that students generally practice in a controlled setting using equipment only available in the classroom laboratory. However, using smartphones with their built-in sensors and often free apps, many fundamental experiments can be performed outside the laboratory. Taking advantage of these tools often require creative approaches to data collection and exploring alternative strategies for experimental procedures. As examples, we present several experiments using smartphones and apps that record and analyze sound to measure a variety of physical properties.

  20. In situ time-series measurements of subseafloor sediment properties

    Science.gov (United States)

    Wheatcroft, R.A.; Stevens, A.W.; Johnson, R.V.

    2007-01-01

    The capabilities and diversity of subsurface sediment sensors lags significantly from what is available for the water column, thereby limiting progress in understanding time-dependent seabed exchange and high-frequency acoustics. To help redress this imbalance, a new instrument, the autonomous sediment profiler (ASP), is described herein. ASP consists of a four-electrode, Wenner-type resistivity probe and a thermistor that log data at 0.1-cm vertical intervals over a 58-cm vertical profile. To avoid resampling the same spot on the seafloor, the probes are moved horizontally within a 20 times 100-cm-2 area in one of three preselected patterns. Memory and power capacities permit sampling at hourly intervals for up to 3-mo duration. The system was tested in a laboratory tank and shown to be able to resolve high-frequency sediment consolidation, as well as changes in sediment roughness. In a field test off the southern coast of France, the system collected resistivity and temperature data at hourly intervals for 16 d. Coupled with environmental data collected on waves, currents, and suspended sediment, the ASP is shown to be useful for understanding temporal evolution of subsurface sediment porosity, although no large depositional or erosional events occurred during the deployment. Following a rapid decrease in bottom-water temperature, the evolution of the subsurface temperature field was consistent with the 1-D thermal diffusion equation coupled with advection in the upper 3-4 cm. Collectively, the laboratory and field tests yielded promising results on time-dependent seabed change.

  1. Measuring and modelling occupancy time in NHS continuing healthcare

    Directory of Open Access Journals (Sweden)

    Millard Peter H

    2011-06-01

    Full Text Available Abstract Background Due to increasing demand and financial constraints, NHS continuing healthcare systems seek to find better ways of forecasting demand and budgeting for care. This paper investigates two areas of concern, namely, how long existing patients stay in service and the number of patients that are likely to be still in care after a period of time. Methods An anonymised dataset containing information for all funded admissions to placement and home care in the NHS continuing healthcare system was provided by 26 (out of 31 London primary care trusts. The data related to 11289 patients staying in placement and home care between 1 April 2005 and 31 May 2008 were first analysed. Using a methodology based on length of stay (LoS modelling, we captured the distribution of LoS of patients to estimate the probability of a patient staying in care over a period of time. Using the estimated probabilities we forecasted the number of patients that are likely to be still in care after a period of time (e.g. monthly. Results We noticed that within the NHS continuing healthcare system there are three main categories of patients. Some patients are discharged after a short stay (few days, some others staying for few months and the third category of patients staying for a long period of time (years. Some variations in proportions of discharge and transition between types of care as well as between care groups (e.g. palliative, functional mental health were observed. A close agreement of the observed and the expected numbers of patients suggests a good prediction model. Conclusions The model was tested for care groups within the NHS continuing healthcare system in London to support Primary Care Trusts in budget planning and improve their responsiveness to meet the increasing demand under limited availability of resources. Its applicability can be extended to other types of care, such as hospital care and re-ablement. Further work will be geared towards

  2. Pulse shape analyzer/timing-SCA application to beta measurement

    International Nuclear Information System (INIS)

    Selvi, S.; Celiktas, C.

    2001-01-01

    Electrical noise contribution to pulse height distributions from beta sources due to BC-400 plastic scintillator(PS), preamplifier and spectroscopy amplifier was rejected by setting the electronic set-up processing of the modified beta spectrometer consisted of pulse shape analyzer/timing single channel analyzer (PSA/SCA) and related complementary equipments. Improved noise rejection performance was evaluated in terms of elimination practically only all of the noise band of C-14 and Tl-204 spectra obtained using the two alternate beta spectrometer

  3. Time interval measurement between two emissions: Ar + Au

    International Nuclear Information System (INIS)

    Bizard, G.; Bougault, R.; Brou, R.; Buta, A.; Durand, D.; Genoux-Lubain, A.; Hamdani, T.; Horn, D.; Laville, J.L.; Le Brun, C.; Lecolley, J.F.; Louvel, M.; Peter, J.; Regimbart, R.; Steckmeyer, J.C.; Tamain, B.

    1998-01-01

    The Ar + Au system was studied at two bombarding energies, 30 and 60 A.MeV. The comparison of the distributions of fragment emission angles in central collisions was carried out by means of a simulation allowing the emission time interval variation. It was found that this interval depends on the bombarding energy (i.e. deposed excitation energy).For 30 A.MeV this interval is 500 fm/c (0.33 · 10 -23 s), while for 60 A.MeV it is so short that the multifragmentation concept can be used

  4. Methodological issues in measures of imitative reaction times.

    Science.gov (United States)

    Aicken, Michael D; Wilson, Andrew D; Williams, Justin H G; Mon-Williams, Mark

    2007-04-01

    Ideomotor (IM) theory suggests that observing someone else perform an action activates an internal motor representation of that behaviour within the observer. Evidence supporting the case for an ideomotor theory of imitation has come from studies that show imitative responses to be faster than the same behavioural measures performed in response to spatial cues. In an attempt to replicate these findings, we manipulated the salience of the visual cue and found that we could reverse the advantage of the imitative cue over the spatial cue. We suggest that participants utilised a simple visuomotor mechanism to perform all aspects of this task, with performance being driven by the relative visual salience of the stimuli. Imitation is a more complex motor skill that would constitute an inefficient strategy for rapid performance.

  5. Radiation exposure in nuclear medicine: real-time measurement

    International Nuclear Information System (INIS)

    Sylvain, Iara; Bok, Bernard; X. Bichat University, Paris

    2002-01-01

    French regulations have introduced the use of electronic dosimeters for personnel monitoring of workers. In order to evaluate the exposure from diagnostic procedures to nuclear medicine staff, individual whole-body doses were measured daily with electronic (digital) personal dosimeters during 20 consecutive weeks and correlated with the work load of each day. Personal doses remained always below 20 mu Sv/d under normal working conditions. Radiation exposure levels were highest to tech staff, nurses and stretcher-bearers. The extrapolated annual cumulative doses for all staff remained less than 10% of the maximum legal limit for exposed workers (2 mSv/yr). Electronic dosimeters are not technically justified for routine survey of staff. The high sensitivity and immediate reading of electronic semiconductor dosimeters may become very useful for exposure control under risky working conditions. It may become an important help for optimising radiation protection. (author)

  6. Quantum optical arbitrary waveform manipulation and measurement in real time.

    Science.gov (United States)

    Kowligy, Abijith S; Manurkar, Paritosh; Corzo, Neil V; Velev, Vesselin G; Silver, Michael; Scott, Ryan P; Yoo, S J B; Kumar, Prem; Kanter, Gregory S; Huang, Yu-Ping

    2014-11-17

    We describe a technique for dynamic quantum optical arbitrary-waveform generation and manipulation, which is capable of mode selectively operating on quantum signals without inducing significant loss or decoherence. It is built upon combining the developed tools of quantum frequency conversion and optical arbitrary waveform generation. Considering realistic parameters, we propose and analyze applications such as programmable reshaping of picosecond-scale temporal modes, selective frequency conversion of any one or superposition of those modes, and mode-resolved photon counting. We also report on experimental progress to distinguish two overlapping, orthogonal temporal modes, demonstrating over 8 dB extinction between picosecond-scale time-frequency modes, which agrees well with our theory. Our theoretical and experimental progress, as a whole, points to an enabling optical technique for various applications such as ultradense quantum coding, unity-efficiency cavity-atom quantum memories, and high-speed quantum computing.

  7. OPERA’s measurement: theory’s speaking time

    CERN Multimedia

    CERN Bulletin

    2011-01-01

    Einstein’s theory of relativity proven wrong, time travel finally possible, all our knowledge suddenly forced to change: superluminal neutrinos have triggered reactions from around the world. While the buzz spread, the theory community was following the usual scientific procedure, which implies understanding, thinking, reading, imagining, monitoring, reviewing and wondering: how could any theory account for OPERA’s result?   Last week, CERN theorists organised a workshop to discuss OPERA’s recent result. The workshop took place the whole morning of Friday 14 October and saw fruitful discussions among theorists, experimentalists, members of the OPERA Collaboration and members of the CERN community at large. The hot topic : assuming that OPERA’s result is confirmed by other experiments, is there any theory that could “accommodate” it? “We have reviewed a large part of the articles published in arXiv after OPERA made its result p...

  8. GPS coordinate time series measurements in Ontario and Quebec, Canada

    Science.gov (United States)

    Samadi Alinia, Hadis; Tiampo, Kristy F.; James, Thomas S.

    2017-06-01

    New precise network solutions for continuous GPS (cGPS) stations distributed in eastern Ontario and western Québec provide constraints on the regional three-dimensional crustal velocity field. Five years of continuous observations at fourteen cGPS sites were analyzed using Bernese GPS processing software. Several different sub-networks were chosen from these stations, and the data were processed and compared to in order to select the optimal configuration to accurately estimate the vertical and horizontal station velocities and minimize the associated errors. The coordinate time series were then compared to the crustal motions from global solutions and the optimized solution is presented here. A noise analysis model with power-law and white noise, which best describes the noise characteristics of all three components, was employed for the GPS time series analysis. The linear trend, associated uncertainties, and the spectral index of the power-law noise were calculated using a maximum likelihood estimation approach. The residual horizontal velocities, after removal of rigid plate motion, have a magnitude consistent with expected glacial isostatic adjustment (GIA). The vertical velocities increase from subsidence of almost 1.9 mm/year south of the Great Lakes to uplift near Hudson Bay, where the highest rate is approximately 10.9 mm/year. The residual horizontal velocities range from approximately 0.5 mm/year, oriented south-southeastward, at the Great Lakes to nearly 1.5 mm/year directed toward the interior of Hudson Bay at stations adjacent to its shoreline. Here, the velocity uncertainties are estimated at less than 0.6 mm/year for the horizontal component and 1.1 mm/year for the vertical component. A comparison between the observed velocities and GIA model predictions, for a limited range of Earth models, shows a better fit to the observations for the Earth model with the smallest upper mantle viscosity and the largest lower mantle viscosity. However, the

  9. Time interval measurement between two emissions: Kr + Au

    International Nuclear Information System (INIS)

    Aboufirassi, M; Bougault, R.; Brou, R.; Colin, J.; Durand, D.; Genoux-Lubain, A.; Horn, D.; Laville, J.L.; Le Brun, C.; Lecolley, J.F.; Lefebvres, F.; Lopez, O.; Louvel, M.; Mahi, M.; Steckmeyer, J.C.; Tamain, B.

    1998-01-01

    To indicate the method allowing the determination of the emission intervals, the results obtained with the Kr + Au system at 43 and 60 A.MeV are presented. The experiments were performed with the NAUTILUS exclusive detectors. Central collisions were selected by means of a relative velocity criterion to reject the events containing a forward emitted fragment. For the two bombardment energies the data analysis shows that the formation of a compound of mass around A = 200. By comparing the fragment dynamical variables with simulations one can conclude about the simultaneity of the compound deexcitation processes. It was found that a 5 MeV/A is able to reproduce the characteristics of the detected fragments. Also, it was found that to reproduce the dynamical characteristics of the fragments issued from central collisions it was not necessary to superimpose a radial collective energy upon the Coulomb and thermal motion. The distribution of the relative angles between detected fragments is used here as a chronometer. For simultaneous ruptures the small relative angles are forbidden by the Coulomb repulsion, while for sequential processes this interdiction is the more lifted the longer the interval between the two emissions is. For the system discussed here the comparison between simulation and data has been carried out for the extreme cases, i.e. for a vanishing and infinite time interval between the two emissions, respectively. More sophisticated simulations to describe angular distributions between the emitted fragments were also developed

  10. Radiation exposure in nuclear medicine: real-time measurement

    Directory of Open Access Journals (Sweden)

    Iara Sylvain

    2002-09-01

    Full Text Available French regulations have introduced the use of electronic dosimeters for personal monitoring of workers. In order to evaluate the exposure from diagnostic procedures to nuclear medicine staff, individual whole-body doses were measured daily with electronic (digital personal dosimeters during 20 consecutive weeks and correlated with the work load of each day. Personal doses remained always below 20 µSv/d under normal working conditions. Radiation exposure levels were highest to tech staff, nurses and stretcher-bearers. The extrapolated annual cumulative doses for all staff remained less than 10 % of the maximum legal limit for exposed workers (2 mSv/yr. Electronic dosimeters are not technically justified for routine survey of staff. The high sensitivity and immediate reading of electronic semiconductor dosimeters may become very useful for exposure control under risky working conditions. It may become an important help for optimising radiation protection.A legislação francesa introduziu o uso de dosímetros eletrônicos para monitoração da exposição do trabalhador. Afim de avaliar a exposição do trabalhador proveniente de exames diagnósticos em medicina nuclear, doses individuais do corpo inteiro foram medidas diariamente com dosímetros eletrônicos (digitais durante 20 semanas consecutivas e correlatas com as atividades de trabalho de cada dia. As doses foram sempre inferiores à 20 µSv por dia em condições normais de trabalho. Os níveis de exposição de radiação mais elevados foram para os enfermeiros, manipuladores e maqueiros. A extrapolação da dose anual para todos os trabalhadores foi menos que 10 % do limite máximo legal para os trabalhadores expostos (2 mSv/ano. Dosímetros eletrônicos não são tecnicamente justificados para a o controle de rotina da exposição dos trabalhadores, mas a alta sensibilidade e a leitura imediata desses dosímetros podem vir a serem muito úteis para o controle da exposição em condi

  11. Time-resolved measurements with intense ultrashort laser pulses: a 'molecular movie' in real time

    International Nuclear Information System (INIS)

    Rudenko, A; Ergler, Th; Feuerstein, B; Zrost, K; Schroeter, C D; Moshammer, R; Ullrich, J

    2007-01-01

    We report on the high-resolution multidimensional real-time mapping of H 2 + and D 2 + nuclear wave packets performed employing time-resolved three-dimensional Coulomb explosion imaging with intense laser pulses. Exploiting a combination of a 'reaction microscope' spectrometer and a pump-probe setup with two intense 6-7 fs laser pulses, we simultaneously visualize both vibrational and rotational motion of the molecule, and obtain a sequence of snapshots of the squared ro-vibrational wave function with time-step resolution of ∼ 0.3 fs, allowing us to reconstruct a real-time movie of the ultrafast molecular motion. We observe fast dephasing, or 'collapse' of the vibrational wave packet and its subsequent revival, as well as signatures of rotational excitation. For D 2 + we resolve also the fractional revivals resulting from the interference between the counter-propagating parts of the wave packet

  12. Ultrafast time measurements by time-correlated single photon counting coupled with superconducting single photon detector

    Energy Technology Data Exchange (ETDEWEB)

    Shcheslavskiy, V., E-mail: vis@becker-hickl.de; Becker, W. [Becker & Hickl GmbH, Nahmitzer Damm 30, 12277 Berlin (Germany); Morozov, P.; Divochiy, A. [Scontel, Rossolimo St., 5/22-1, Moscow 119021 (Russian Federation); Vakhtomin, Yu. [Scontel, Rossolimo St., 5/22-1, Moscow 119021 (Russian Federation); Moscow State Pedagogical University, 1/1 M. Pirogovskaya St., Moscow 119991 (Russian Federation); Smirnov, K. [Scontel, Rossolimo St., 5/22-1, Moscow 119021 (Russian Federation); Moscow State Pedagogical University, 1/1 M. Pirogovskaya St., Moscow 119991 (Russian Federation); National Research University Higher School of Economics, 20 Myasnitskaya St., Moscow 101000 (Russian Federation)

    2016-05-15

    Time resolution is one of the main characteristics of the single photon detectors besides quantum efficiency and dark count rate. We demonstrate here an ultrafast time-correlated single photon counting (TCSPC) setup consisting of a newly developed single photon counting board SPC-150NX and a superconducting NbN single photon detector with a sensitive area of 7 × 7 μm. The combination delivers a record instrument response function with a full width at half maximum of 17.8 ps and system quantum efficiency ∼15% at wavelength of 1560 nm. A calculation of the root mean square value of the timing jitter for channels with counts more than 1% of the peak value yielded about 7.6 ps. The setup has also good timing stability of the detector–TCSPC board.

  13. Methodological issues in the estimation of parental time – Analysis of measures in a Canadian time-use survey

    OpenAIRE

    Cara B. Fedick; Shelley Pacholok; Anne H. Gauthier

    2005-01-01

    Extensive small scale studies have documented that when people assume the role of assisting a person with impairments or an older person, care activities account for a significant portion of their daily routines. Nevertheless, little research has investigated the problem of measuring the time that carers spend in care-related activities. This paper contrasts two different measures of care time – an estimated average weekly hours question in the 1998 Australian Survey of Disability, Ageing and...

  14. Real time alpha value measurement with Feynman-α method utilizing time series data acquisition on low enriched uranium system

    International Nuclear Information System (INIS)

    Tonoike, Kotaro; Yamamoto, Toshihiro; Watanabe, Shoichi; Miyoshi, Yoshinori

    2003-01-01

    As a part of the development of a subcriticality monitoring system, a system which has a time series data acquisition function of detector signals and a real time evaluation function of alpha value with the Feynman-alpha method was established, with which the kinetic parameter (alpha value) was measured at the STACY heterogeneous core. The Hashimoto's difference filter was implemented in the system, which enables the measurement at a critical condition. The measurement result of the new system agreed with the pulsed neutron method. (author)

  15. Outdoor time, physical activity and sedentary time among young children: The 2012-2013 Canadian Health Measures Survey.

    Science.gov (United States)

    Larouche, Richard; Garriguet, Didier; Tremblay, Mark S

    2017-03-01

    Previous studies have shown that children who spend more time outdoors are more active and spend less time sedentary, but these studies were limited by the use of small convenience samples. We examined the relationship between outdoor time and measures of physical activity (PA), screen time and sedentary time in a nationally-representative sample of young children. Parental reports of outdoor time were obtained for 594 children aged 3-6 years (47.8% girls) who participated in the 2012-2013 Canadian Health Measures Survey. Participants were asked to wear an Actical accelerometer for seven consecutive days. Outdoor time and screen time were assessed by parent reports. The relationships between outdoor time and measures of PA, screen time and sedentary time were examined with linear regression models. Adherence to PA guidelines was estimated based on a betabinomial distribution, and adherence with the screen time guidelines was assessed through logistic regression models. All analyses were stratified by age group (3-4 and 5-6 year olds) and adjusted for sex, parental education and household income. Among 5-6 year olds, each additional hour spent outdoors was associated with an additional 10 minutes of moderate-to-vigorous PA (95% CI: 6-14), 27,455 more accelerometer counts/day (95% CI: 11,929-42,980) and an increased likelihood of meeting the PA guidelines (OR = 2.53; 95% CI: 1.68-3.82). No significant relationships were observed among 3-4 year olds. Outdoor time has a large effect on PA among 5-6 year olds at a population level. Future studies should examine the correlates of outdoor time to inform novel PA promotion interventions.

  16. TRANSIT TIMING OBSERVATIONS FROM KEPLER. VIII. CATALOG OF TRANSIT TIMING MEASUREMENTS OF THE FIRST TWELVE QUARTERS

    Energy Technology Data Exchange (ETDEWEB)

    Mazeh, Tsevi; Nachmani, Gil; Holczer, Tomer; Sokol, Gil [School of Physics and Astronomy, Raymond and Beverly Sackler Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 69978 (Israel); Fabrycky, Daniel C. [Department of Astronomy and Astrophysics, University of Chicago, 5640 Ellis Ave., Chicago, IL 60637 (United States); Ford, Eric B.; Ragozzine, Darin [Astronomy Department, University of Florida, Gainesville, FL 32111 (United States); Sanchis-Ojeda, Roberto [Department of Physics and Kavli Institute for Astrophysics and Space Research, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Rowe, Jason F.; Lissauer, Jack J. [NASA Ames Research Center, Moffett Field, CA 94035 (United States); Zucker, Shay [Department of Geophysical, Atmospheric and Planetary Sciences, Raymond and Beverly Sackler Faculty of Exact Sciences Tel Aviv University, 69978 Tel Aviv (Israel); Agol, Eric [Department of Astronomy, Box 351580, University of Washington, Seattle, WA 98195 (United States); Carter, Joshua A. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Quintana, Elisa V. [SETI Institute, 189 Bernardo Ave, Suite 100, Mountain View, CA 94043 (United States); Steffen, Jason H. [Fermilab Center for Particle Astrophysics, P.O. Box 500, MS 127, Batavia, IL 60510 (United States); Welsh, William [Astronomy Department, San Diego State University, 5500 Campanile Drive, San Diego, CA 92182 (United States)

    2013-10-01

    Following the works of Ford et al. and Steffen et al. we derived the transit timing of 1960 Kepler objects of interest (KOIs) using the pre-search data conditioning light curves of the first twelve quarters of the Kepler data. For 721 KOIs with large enough signal-to-noise ratios, we obtained also the duration and depth of each transit. The results are presented as a catalog for the community to use. We derived a few statistics of our results that could be used to indicate significant variations. Including systems found by previous works, we have found 130 KOIs that showed highly significant times of transit variations (TTVs) and 13 that had short-period TTV modulations with small amplitudes. We consider two effects that could cause apparent periodic TTV—the finite sampling of the observations and the interference with the stellar activity, stellar spots in particular. We briefly discuss some statistical aspects of our detected TTVs. We show that the TTV period is correlated with the orbital period of the planet and with the TTV amplitude.

  17. Comparison of Objectively Measured and Self-reported Time Spent Sitting

    DEFF Research Database (Denmark)

    Lagersted-Olsen, Julie; Korshøj, M; Skotte, J

    2014-01-01

    Until recently, methods for objective quantification of sitting time have been lacking. The aim of this study was to validate self-reported measures against objectively measured total sitting time and longest continuous time with uninterrupted sitting during working hours, leisure time on workday...... a retrospective 7-day questionnaire. A generalized linear model showed the difference between the methods. No significant correlations were found between objective and self-reported sitting time (r...

  18. HiRISE: The People's Camera

    Science.gov (United States)

    McEwen, A. S.; Eliason, E.; Gulick, V. C.; Spinoza, Y.; Beyer, R. A.; HiRISE Team

    2010-12-01

    The High Resolution Imaging Science Experiment (HiRISE) camera, orbiting Mars since 2006 on the Mars Reconnaissance Orbiter (MRO), has returned more than 17,000 large images with scales as small as 25 cm/pixel. From it’s beginning, the HiRISE team has followed “The People’s Camera” concept, with rapid release of useful images, explanations, and tools, and facilitating public image suggestions. The camera includes 14 CCDs, each read out into 2 data channels, so compressed images are returned from MRO as 28 long (up to 120,000 line) images that are 1024 pixels wide (or binned 2x2 to 512 pixels, etc.). This raw data is very difficult to use, especially for the public. At the HiRISE operations center the raw data are calibrated and processed into a series of B&W and color products, including browse images and JPEG2000-compressed images and tools to make it easy for everyone to explore these enormous images (see http://hirise.lpl.arizona.edu/). Automated pipelines do all of this processing, so we can keep up with the high data rate; images go directly to the format of the Planetary Data System (PDS). After students visually check each image product for errors, they are fully released just 1 month after receipt; captioned images (written by science team members) may be released sooner. These processed HiRISE images have been incorporated into tools such as Google Mars and World Wide Telescope for even greater accessibility. 51 Digital Terrain Models derived from HiRISE stereo pairs have been released, resulting in some spectacular flyover movies produced by members of the public and viewed up to 50,000 times according to YouTube. Public targeting began in 2007 via NASA Quest (http://marsoweb.nas.nasa.gov/HiRISE/quest/) and more than 200 images have been acquired, mostly by students and educators. At the beginning of 2010 we released HiWish (http://www.uahirise.org/hiwish/), opening HiRISE targeting to anyone in the world with Internet access, and already more

  19. Measures of spike train synchrony for data with multiple time scales

    NARCIS (Netherlands)

    Satuvuori, Eero; Mulansky, Mario; Bozanic, Nebojsa; Malvestio, Irene; Zeldenrust, Fleur; Lenk, Kerstin; Kreuz, Thomas

    2017-01-01

    Background Measures of spike train synchrony are widely used in both experimental and computational neuroscience. Time-scale independent and parameter-free measures, such as the ISI-distance, the SPIKE-distance and SPIKE-synchronization, are preferable to time scale parametric measures, since by

  20. Procedure to determine the two channel timing measurement accuracy and precision of a digital oscilloscope

    International Nuclear Information System (INIS)

    Johnson, M.; Matulik, M.

    1994-01-01

    The digital oscilloscope allows one to make numerous timing measurements, but just how good are those measurements? This document describes a procedure which can be used to determine the accuracy and precision to which a digital oscilloscope can make various two channel timing measurements

  1. How to statistically analyze nano exposure measurement results: Using an ARIMA time series approach

    NARCIS (Netherlands)

    Klein Entink, R.H.; Fransman, W.; Brouwer, D.H.

    2011-01-01

    Measurement strategies for exposure to nano-sized particles differ from traditional integrated sampling methods for exposure assessment by the use of real-time instruments. The resulting measurement series is a time series, where typically the sequential measurements are not independent from each

  2. On Capillary Rise and Nucleation

    Science.gov (United States)

    Prasad, R.

    2008-01-01

    A comparison of capillary rise and nucleation is presented. It is shown that both phenomena result from a balance between two competing energy factors: a volume energy and a surface energy. Such a comparison may help to introduce nucleation with a topic familiar to the students, capillary rise. (Contains 1 table and 3 figures.)

  3. KAZAKHSTAN ECONOMIC SAFETY RISE

    Directory of Open Access Journals (Sweden)

    G. G. Rakhmatulina

    2011-01-01

    Full Text Available Economic safety of the Republic of Kazakhstan essentially depends on how the Republic’s transit potential is used and how internal demands in energy resources are met. There are many legal, investment, technological and other challenges with respect to these aspects. Main ways to solvethe problems are: to form potential transit development legislation conforming to respective international standards; to take specific transport infrastructure modernization measures; to simplify railway and road transport state border crossing procedures; to develop service facilitiesalong interstate trunk roads; to improve competitiveness of domestic oil-processing enterprises; to further develop integrative cooperation withRussia in the oil processing field.

  4. The 1988 coal outlook: steadily rising consumption

    Energy Technology Data Exchange (ETDEWEB)

    Soras, C.G.; Stodden, J.R.

    1987-12-01

    Total coal use - domestic and foreign - will reach 910 million tons in 1988, an expansion of 1.3% from an estimated 898 million tons in 1987. The overall rise in consumption will add to inventory needs. Moreover, lower interest rates cut effective carrying costs and further encourage the holding of coal stocks by users. The results will be a gain in inventories of 3.5 tons by the end of 1988. As a result of all these factors, coal production is anticipated to rise by 11.6 million tons, or 1.2%, which projects firm markets in a time of relatively soft economic conditions in the USA. 2 tabs.

  5. Strategic advantages of high-rise construction

    Directory of Open Access Journals (Sweden)

    Yaskova Natalya

    2018-01-01

    Full Text Available Traditional methods to assess the competitiveness of different types of real estate in the context of huge changes of new technological way of life don’t provide building solutions that would be correct from a strategic perspective. There are many challenges due to changes in the consumers’ behavior in the housing area. A multiplicity of life models, a variety of opportunities and priorities, traditions and new trends in construction should be assessed in terms of prospective benefits in the environment of the emerging new world order. At the same time, the mane discourse of high-rise construction mainly relates to its design features, technical innovations, and architectural accents. We need to clarify the criteria for economic evaluation of high-rise construction in order to provide decisions with clear and quantifiable contexts. The suggested approach to assessing the strategic advantage of high-rise construction and the prospects for capitalization of high-rise buildings poses new challenges for the economy to identify adequate quantitative assessment methods of the high-rise buildings economic efficiency, taking into account all stages of their life cycle.

  6. Strategic advantages of high-rise construction

    Science.gov (United States)

    Yaskova, Natalya

    2018-03-01

    Traditional methods to assess the competitiveness of different types of real estate in the context of huge changes of new technological way of life don't provide building solutions that would be correct from a strategic perspective. There are many challenges due to changes in the consumers' behavior in the housing area. A multiplicity of life models, a variety of opportunities and priorities, traditions and new trends in construction should be assessed in terms of prospective benefits in the environment of the emerging new world order. At the same time, the mane discourse of high-rise construction mainly relates to its design features, technical innovations, and architectural accents. We need to clarify the criteria for economic evaluation of high-rise construction in order to provide decisions with clear and quantifiable contexts. The suggested approach to assessing the strategic advantage of high-rise construction and the prospects for capitalization of high-rise buildings poses new challenges for the economy to identify adequate quantitative assessment methods of the high-rise buildings economic efficiency, taking into account all stages of their life cycle.

  7. Directional spectrum of ocean waves from array measurements using phase/time/path difference methods

    Digital Repository Service at National Institute of Oceanography (India)

    Fernandes, A.A.; Sarma, Y.V.B.; Menon, H.B.

    Wave direction has for the first time been consistently, accurately and unambiguously evaluated from array measurements using the phase/time/path difference (PTPD) methods of Esteva in case of polygonal arrays and Borgman in case of linear arrays...

  8. Comparison of methods for measuring travel time at Florida freeways and arterials.

    Science.gov (United States)

    2014-07-01

    Travel time is an important performance measure used to assess the traffic operational quality of various types of highway : facilities. Previous research funded by the Florida Department of Transportation (FDOT) on travel time reliability developed,...

  9. Fission time-scale from the measurement of pre-scission light ...

    Indian Academy of Sciences (India)

    and hence can only probe a part of the fission time distribution. .... with the conclusion of recent fission time-scale measurements using the fission probability ... using the statistical model code JOANNE2 suitably modified to include the GDR ...

  10. Measuring border delay and crossing times at the US-Mexico border : part II. Guidebook for analysis and dissemination of border crossing time and wait time data.

    Science.gov (United States)

    2012-06-01

    The purpose of this guidebook is to describe to local, regional, and State agencies how to analyze and disseminate data collected by a radio frequency identification (RFID)-based system to measure travel times of commercial vehicles, which is referre...

  11. Real-time particle volume fraction measurement in centrifuges by wireless electrical resistance detector

    International Nuclear Information System (INIS)

    Nagae, Fumiya; Okawa, Kazuya; Matsuno, Shinsuke; Takei, Masahiro; Zhao Tong; Ichijo, Noriaki

    2015-01-01

    In this study, wireless electrical resistance detector is developed as first step in order to develop electrical resistance tomography (ERT) that are attached wireless communication, and miniaturized. And the particle volume fraction measurement results appropriateness is qualitatively examined. The real-time particle volume fraction measurement is essential for centrifuges, because rotational velocity and supply should be controlled based on the results in order to obtain the effective separation, shorten process time and save energy. However, a technique for the particle volume fraction measurement in centrifuges has not existed yet. In other words, the real-time particle volume fraction measurement in centrifuges becomes innovative technologies. The experiment device reproduces centrifugation in two-phase using particle and salt solution as measuring object. The particle concentration is measured changing rotational velocity, supply and measurement section position. The measured concentration changes coincide with anticipated tendency of concentration changes. Therefore the particle volume fraction measurement results appropriateness are qualitatively indicated. (author)

  12. Measuring the corrosion rate of steel in concrete – effect of measurement technique, polarisation time and current

    DEFF Research Database (Denmark)

    Nygaard, Peter Vagn; Geiker, Mette Rica

    2012-01-01

    , are in some studies considered the main reasons for the variations. This paper presents an experimental study on the quantitative effect of polarisation time and current on the measured polarisation resistance – and thus the corrosion current density – of passively and actively corroding steel. Two...... electrochemical techniques often used in instruments for on-site corrosion rate measurements are investigated. On passively corroding reinforcement the measured polarisation resistance was for both techniques found to be highly affected by the polarisation time and current and no plateaus at either short or long...... rate for actively corroding steel. For both techniques guidelines for polarisation times and currents are given for (on-site) non-destructive corrosion rate measurements on reinforcement steel in concrete....

  13. Measurement and Prediction of Time-independent and Time-dependent Rheological Behavior of Waxy Crude Oil

    OpenAIRE

    Yavar Karimi; Ali Reza Solaimany Nazar

    2017-01-01

    Wax deposition phenomenon changes the rheological behavior of waxy crude oil completely. In the current work, the rheological time-dependent and time-independent behaviors of waxy crude oil samples are studied and flow curve and compliance function are measured for the oil samples with various wax contents at different temperatures. A decrease in temperature and an increase in wax content lead to an increase in the viscosity and yield stress but a significant drop in compliance function. A mo...

  14. Application of a rising plate meter to estimate forage yield on dairy farms in Pennsylvania

    Science.gov (United States)

    Accurately assessing pasture forage yield is necessary for producers who want to budget feed expenses and make informed pasture management decisions. Clipping and weighing forage from a known area is a direct method to measure pasture forage yield, however it is time consuming. The rising plate mete...

  15. Experimental evaluation of rigor mortis. VIII. Estimation of time since death by repeated measurements of the intensity of rigor mortis on rats.

    Science.gov (United States)

    Krompecher, T

    1994-10-21

    The development of the intensity of rigor mortis was monitored in nine groups of rats. The measurements were initiated after 2, 4, 5, 6, 8, 12, 15, 24, and 48 h post mortem (p.m.) and lasted 5-9 h, which ideally should correspond to the usual procedure after the discovery of a corpse. The experiments were carried out at an ambient temperature of 24 degrees C. Measurements initiated early after death resulted in curves with a rising portion, a plateau, and a descending slope. Delaying the initial measurement translated into shorter rising portions, and curves initiated 8 h p.m. or later are comprised of a plateau and/or a downward slope only. Three different phases were observed suggesting simple rules that can help estimate the time since death: (1) if an increase in intensity was found, the initial measurements were conducted not later than 5 h p.m.; (2) if only a decrease in intensity was observed, the initial measurements were conducted not earlier than 7 h p.m.; and (3) at 24 h p.m., the resolution is complete, and no further changes in intensity should occur. Our results clearly demonstrate that repeated measurements of the intensity of rigor mortis allow a more accurate estimation of the time since death of the experimental animals than the single measurement method used earlier. A critical review of the literature on the estimation of time since death on the basis of objective measurements of the intensity of rigor mortis is also presented.

  16. A time-series method for automated measurement of changes in mitotic and interphase duration from time-lapse movies.

    Directory of Open Access Journals (Sweden)

    Frederic D Sigoillot

    Full Text Available Automated time-lapse microscopy can visualize proliferation of large numbers of individual cells, enabling accurate measurement of the frequency of cell division and the duration of interphase and mitosis. However, extraction of quantitative information by manual inspection of time-lapse movies is too time-consuming to be useful for analysis of large experiments.Here we present an automated time-series approach that can measure changes in the duration of mitosis and interphase in individual cells expressing fluorescent histone 2B. The approach requires analysis of only 2 features, nuclear area and average intensity. Compared to supervised learning approaches, this method reduces processing time and does not require generation of training data sets. We demonstrate that this method is as sensitive as manual analysis in identifying small changes in interphase or mitotic duration induced by drug or siRNA treatment.This approach should facilitate automated analysis of high-throughput time-lapse data sets to identify small molecules or gene products that influence timing of cell division.

  17. Contribution to time resolved X-ray fluence and differential spectra measurement method improvement in 5-200 KeV range. Application to pulsed emission sources

    International Nuclear Information System (INIS)

    Vie, M.

    1983-09-01

    Two types of sensors have been developed to measure locally the time-resolved fluence and differential energetic spectrum of pulsed X-ray in the energy range 5 to 200 keV. Rise time of these sensors is very short (10 ns) in order to permit time-resolved measurements. Fluence sensors have been developed by putting filters in front of detector in order to make sensor response independent of X-ray energy and proportional to X-ray fluence. The energetic differential spectrum was calculated by way of a method similar to the ROSS method but using filters separated within a pair defining adjacent spectral width. A detailed analysis of uncertainties affecting calculated fluence and spectrum has been done [fr

  18. Longitudinal development of air-shower electrons studied from the arrival time distributions of atmospheric Cerenkov light measured at 5200 m above sea level

    International Nuclear Information System (INIS)

    Inoue, N.; Kaneko, T.; Yoshii, H.

    1985-01-01

    The longitudinal development of electrons in extensive air showers before the maximum has been studied by measuring the arrival time distributions of atmospheric Cerenkov light from air showers, with primary energies in the range 6 x 10 15 to 2 x 10 17 eV, in the Chacaltaya air-shower array. These arrival time distributions are consistent with those calculated using a model of particle interactions which contain Feynman scaling in the fragmentation region, an Esup(1/2) multiplicity law in the pionisation region and a rising cross section for primary protons. Such a model also reproduces the arrival time distributions of Cerenkov light measured in the Akeno air-shower array as described in the preceding paper, which implies a very fast development before the maximum and a slow development after the maximum. (author)

  19. Progressive Collapse of High-Rise Buildings from Fire

    Directory of Open Access Journals (Sweden)

    Pershakov Valerii

    2016-01-01

    Full Text Available Considers ensuring the stability of structures of high-rise buildings against progressive collapse due to fire, proposed measures to ensure the stability of high-rise buildings due to progressive collapse. The analysis of large fires in high-rise buildings with progressive collapse and review of the literature on the issue of progressive collapse. The analysis of the Ukrainian normative documents on progressive collapse resistance.

  20. Time-of-flight measurements of heavy ions using Si PIN diodes

    Energy Technology Data Exchange (ETDEWEB)

    Strekalovsky, A. O., E-mail: alex.strek@bk.ru; Kamanin, D. V. [Joint Institute for Nuclear Research (Russian Federation); Pyatkov, Yu. V. [National Nuclear Research University MEPhI (Moscow Engineering Physics Institute) (Russian Federation); Kondratyev, N. A.; Zhuchko, V. E. [Joint Institute for Nuclear Research (Russian Federation); Ilić, S. [University of Novi Sad (Serbia); Alexandrov, A. A.; Alexandrova, I. A. [Joint Institute for Nuclear Research (Russian Federation); Jacobs, N. [University of Stellenbosch, Faculty of Military Science, Military Academy (South Africa); Kuznetsova, E. A.; Mishinsky, G. V.; Strekalovsky, O. V. [Joint Institute for Nuclear Research (Russian Federation)

    2016-12-15

    A new off-line timing method for PIN diode signals is presented which allows the plasma delay effect to be suppressed. Velocities of heavy ions measured by the new method are in good agreement within a wide range of masses and energies with velocities measured by time stamp detectors based on microchannel plates.

  1. Defining and measuring the mean residence time of lateral surface transient storage zones in small streams

    Science.gov (United States)

    T.R. Jackson; R. Haggerty; S.V. Apte; A. Coleman; K.J. Drost

    2012-01-01

    Surface transient storage (STS) has functional significance in stream ecosystems because it increases solute interaction with sediments. After volume, mean residence time is the most important metric of STS, but it is unclear how this can be measured accurately or related to other timescales and field-measureable parameters. We studied mean residence time of lateral...

  2. On the determinants of measurement error in time-driven costing

    NARCIS (Netherlands)

    Cardinaels, E.; Labro, E.

    2008-01-01

    Although time estimates are used extensively for costing purposes, they are prone to measurement error. In an experimental setting, we research how measurement error in time estimates varies with: (1) the level of aggregation in the definition of costing system activities (aggregated or

  3. Time-of-Flight Adjustment Procedure for Acoustic Measurements in Structural Timber

    Science.gov (United States)

    Danbiel F. Llana; Guillermo Iñiguez-Gonzalez; Francisco Arriaga; Xiping Wang

    2016-01-01

    The effect of timber length on time-of-flight acoustic longitudinal measurements was investigated on the structural timber of four Spanish species: radiata pine (Pinus radiata D. Don), Scots pine (Pinus sylvestris L.), laricio pine (Pinus nigra Arn.), and maritime pine (Pinus pinaster Ait.). Time-of-flight longitudinal measurements were conducted on 120 specimens of...

  4. Applied measuring techniques for the investigation of time-dependent flow phenomena in centrifugal compressors

    International Nuclear Information System (INIS)

    Hass, U.; Haupt, U.; Jansen, M.; Kassens, K.; Knapp, P.; Rautenberg, M.

    1978-01-01

    During the past 10 years new measuring techniques have been developed for the experimental investigation of highly loaded centrifugal compressors. These measuring techniques take into account the time dependency of the fluctuating physical quantities such as pressure, temperature, and velocity. Some key points of these experimental techniques are shown and explained in this paper. An important basis for such measurements is the accurate dynamic calibration of the measuring apparatus. In addition, some problems involved analyzing measured signals are dealt with and pressure measurements and their interpretation are shown. Finally optical, acoustical and vibrational measuring procedures are described which are additionally used for the investigation of non-stationary flow phenomena. (orig.) [de

  5. Stopped-flow technique for transit time measurement in a gas jet

    International Nuclear Information System (INIS)

    Rengan, K.; Lin, J.; Lim, T.; Meyer, R.A.; Harrell, J.

    1985-01-01

    A 'stopped-flow' technique for the measurement of transit time of reaction products in a gas jet is described. The method involved establishing the gas flow through the jet system when the reactor is operating steadily and allowing the pressure to reach equilibrium values. The gas flow is stopped by means of electrically operated valves. The transit-time measurement is achieved by opening the valves and initiating the multiscanning of total activity simultaneously. The value obtained agrees well with the transit time measured by pulsing the reactor. The 'stopped-flow' technique allows on-line measurement of transit time in any gas jet system where the physical transportation time is the major component of the transit time. This technique is especially useful for systems installed in reactors which do not have pulsing capability. (orig.)

  6. New layout of time resolved beam energy spectrum measurement for dragon-I

    International Nuclear Information System (INIS)

    Liao Shuqing; Zhang Kaizhi; Shi Jinshui

    2010-01-01

    A new layout of time resolved beam energy spectrum measurement is proposed for Dragon-I by a new method named RBS (rotating beams in solenoids). The basic theory of RBS and the new layout are presented and the measuring error is also discussed. The derived time resolved beam energy spectrum is discrete and is determined by measuring the beam's rotating angle and expanding width through a group of solenoids at the export of Dragon-I. (authors)

  7. Microprocessor-controlled time domain reflectometer for dynamic shock position measurements

    International Nuclear Information System (INIS)

    Virchow, C.F.; Conrad, G.E.; Holt, D.M.; Hodson, E.K.

    1980-01-01

    Time-domain reflectometry is used in a novel way to measure dynamically shock propagation in various media. The primary component in this measurement system is a digital time domain reflectometer, which uses local intelligence, a Motorola 6800 microprocessor, to make the unit adaptable and versatile. The recorder, its operating theory and its method of implementation are described and typical data are reviewed. Applications include nuclear explosion yield estimates and explosive energy flow measurements

  8. Measuring the Earth System in a Time of Global Environmental Change with Image Spectroscopy

    Science.gov (United States)

    Green, Robert O.

    2005-01-01

    Measuring the Earth system in a time of global environmental change. Imaging Spectroscopy enables remote measurement. Remote Measurement determination of the properties of the Earth's surface and atmosphere through the physics, chemistry and biology of the interaction of electromagnetic energy with matter.

  9. Direct Measurements of Smartphone Screen-Time: Relationships with Demographics and Sleep

    OpenAIRE

    Christensen, Matthew A.; Bettencourt, Laura; Kaye, Leanne; Moturu, Sai T.; Nguyen, Kaylin T.; Olgin, Jeffrey E.; Pletcher, Mark J.; Marcus, Gregory M.

    2016-01-01

    Background Smartphones are increasingly integrated into everyday life, but frequency of use has not yet been objectively measured and compared to demographics, health information, and in particular, sleep quality. Aims The aim of this study was to characterize smartphone use by measuring screen-time directly, determine factors that are associated with increased screen-time, and to test the hypothesis that increased screen-time is associated with poor sleep. Methods We performed a cross-sectio...

  10. Measurement of gastric emptying time: a comparative study between nonisotopic aspiration method and new radioisotopic technique

    International Nuclear Information System (INIS)

    Chaudhuri, T.K.; Greenwald, A.J.; Heading, R.C.; Chaudhuri, T.K.

    1975-01-01

    A comparative study between modified conventional saline load test and the more recently introduced radioisotopic method was run in 8 normal volunteers. Each subject underwent at least three studies by each of the two methods: (1) aspiration method Goldstein and Boyle incorporating our modification, and (2) an isotopic method employing a gamma camera with a computer. A liquid metal of isotonic saline was used with or without /sup 99m/Tc-DTPA. The results indicated that the gastric emptying T 1 / 2 (8.8 +- 3.5 min) obtained by saline load test was shorter than that obtained by isotopic method (12 +- 3 min). This discrepancy was most likely due to inherent error (incomplete aspiration of the gastric fluid) in the former method giving rise to a false faster emptying time. Moreover, the variations in T 1 / 2 value in the same individual was much more in the aspiration method than it was in the isotopic method

  11. Time-resolved photoluminescence measurements of InP/ZnS quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Pham Thi Thuy; Ung Thi Dieu Thuy; Tran Thi Kim Chi; Le Quang Phuong; Nguyen Quang Liem [Institute of Materials Science, VAST, 18 Hoang Quoc Viet, Cau Giay, Hanoi (Viet Nam); Li Liang; Reiss, Peter [CEA Grenoble, DSM/INAC/SPrAM (UMR 5819 CEA-CNRS-Universite Joseph Fourier)/LEMOH, 17 rue des Martyrs, 38054 Grenoble cedex 9 (France)], E-mail: liemnq@ims.vast.ac.vn

    2009-09-01

    This paper reports the results on the time-resolved photoluminescence study of InP/ZnS core/shell quantum dots. The ZnS shell played a decisive role to passivate imperfections on the surface of InP quantum dots, consequently giving rise to a strong enhancement of the photoluminescence from the InP core. Under appropriate excitation conditions, not only the emission from the InP core but also that from the ZnS shell was observed. The emission peak in InP core quantum dots varied as a function of quantum dots size, ranging in the 600 - 700 nm region; while the ZnS shell showed emission in the blue region around 470 nm, which is interpreted as resulting from defects in ZnS.

  12. Use of formwork systems in high-rise construction

    Science.gov (United States)

    Kurakova, Oksana

    2018-03-01

    Erection of high quality buildings and structures within a reasonable time frame is the crucial factor for the competitiveness of any construction organization. The main material used in high-rise construction is insitu reinforced concrete. The technology of its use is directly related to the use of formwork systems. Formwork systems and formwork technologies basically determine the speed of construction and labor intensity of concreting operations. Therefore, it is also possible to achieve the goal of reducing the construction time and labor intensity of works performed by improving the technology of formwork systems use. Currently there are unresolved issues in the area of implementation of monolithic technology projects, and problems related to the selection of a formwork technology, high labor intensity of works, poor quality of materials and structures, etc. are the main ones. The article presents organizational and technological measures, by means of which introduction it is possible to shorten the duration of construction. A comparison of operations performed during formwork installation according to the conventional technology and taking into account the implemented organizational and technological measures is presented. The results of a comparative analysis of economic efficiency assessments are also presented on the example of a specific construction project before and after the implementation of the above mentioned measures. The study showed that introduction of the proposed organizational and technological model taking into account optimization of reinforcing and concreting works significantly improves the efficiency of a high-rise construction project. And further improvement of technologies for the use of insitu reinforced concrete is a promising direction in the construction of high-rise buildings.

  13. Use of formwork systems in high-rise construction

    Directory of Open Access Journals (Sweden)

    Kurakova Oksana

    2018-01-01

    Full Text Available Erection of high quality buildings and structures within a reasonable time frame is the crucial factor for the competitiveness of any construction organization. The main material used in high-rise construction is insitu reinforced concrete. The technology of its use is directly related to the use of formwork systems. Formwork systems and formwork technologies basically determine the speed of construction and labor intensity of concreting operations. Therefore, it is also possible to achieve the goal of reducing the construction time and labor intensity of works performed by improving the technology of formwork systems use. Currently there are unresolved issues in the area of implementation of monolithic technology projects, and problems related to the selection of a formwork technology, high labor intensity of works, poor quality of materials and structures, etc. are the main ones. The article presents organizational and technological measures, by means of which introduction it is possible to shorten the duration of construction. A comparison of operations performed during formwork installation according to the conventional technology and taking into account the implemented organizational and technological measures is presented. The results of a comparative analysis of economic efficiency assessments are also presented on the example of a specific construction project before and after the implementation of the above mentioned measures. The study showed that introduction of the proposed organizational and technological model taking into account optimization of reinforcing and concreting works significantly improves the efficiency of a high-rise construction project. And further improvement of technologies for the use of insitu reinforced concrete is a promising direction in the construction of high-rise buildings.

  14. MRPC-PET: A new technique for high precision time and position measurements

    International Nuclear Information System (INIS)

    Doroud, K.; Hatzifotiadou, D.; Li, S.; Williams, M.C.S.; Zichichi, A.; Zuyeuski, R.

    2011-01-01

    The purpose of this paper is to consider a new technology for medical diagnosis: the MRPC-PET. This technology allows excellent time resolution together with 2-D position information thus providing a fundamental step in this field. The principle of this method is based on the Multigap Resistive Plate Chamber (MRPC) capable of high precision time measurements. We have previously found that the route to precise timing is differential readout (this requires matching anode and cathode strips); thus crossed strip readout schemes traditionally used for 2-D readout cannot be exploited. In this paper we consider the time difference from the two ends of the strip to provide a high precision measurement along the strip; the average time gives precise timing. The MRPC-PET thus provides a basic step in the field of medical technology: excellent time resolution together with 2-D position measurement.

  15. Flight-time spread of uniform field sector magnet system for use in nuclear life-time measurements

    International Nuclear Information System (INIS)

    Sakata, Akihiko; Mamei, Masayuki; Yamada, Yoshihiro; Ohira, Kyozo

    1984-01-01

    A nuclear life-time measurement apparatus incorporating a deflecting β-ray spectrometer with electron pre-accelerator has been constructed. A new arrangement consisting of two double angular focusing sector magnets based on the principle of symmetry has been devised so as to reduce the time spread in the spectrometer, which up till now has been the weak point of such systems. The time spread in the spectrometer was estimated to be asymptotically equals 0.1 ns by a simulation method, and good agreement was obtained between this estimated value and the experimental value. A prompt time resolution of 1.25 ns (FWHM) was obtained. The half-lives of the 199 and 401 keV levels in 75 As were measured with an acceleration voltage up to 30 kV to check the reliability of the apparatus. The values were found to be 0.87+-0.04 ns and 1.74+-0.05 ns, respectively, in good agreement with previous measurements. (author)

  16. Perceptions of Life Changes: An Alternate Measure of Aging through Time.

    Science.gov (United States)

    Suggs, Patricia K.; Kivett, Vira R.

    Retrospective strategies measuring perceived life changes over time can further the advancement of life span developmental research. Researchers have neglected the individual's perception of his/her life changes over time. This study attempts to determine discriminators of change over time as operationalized by perceptions of change. Subjects…

  17. Validation of a simple response-time measure of listening effort

    NARCIS (Netherlands)

    Pals, Carina; Sarampalis, Anastasios; van Rijn, Hedderik; Başkent, Deniz

    This study compares two response-time measures of listening effort that can be combined with a clinical speech test for a more comprehensive evaluation of total listening experience; verbal response times to auditory stimuli (RTaud) and response times to a visual task (RTsvis) in a dual- task

  18. Grasp: Tracing, visualizing and measuring the behavior of real-time systems

    NARCIS (Netherlands)

    Holenderski, M.J.; Heuvel, van den M.M.H.P.; Bril, R.J.; Lukkien, J.J.; Lipari, G.; Cucinotta, T.

    2010-01-01

    Understanding and validating the timing behavior of real-time systems is not trivial. Many real-time operating systems and their development environments do not provide tracing support, and provide only limited visualization, measurements and analysis tools. This paper presents Grasp, a tool for

  19. A position-sensitive start detector for time-of-flight measurement

    International Nuclear Information System (INIS)

    Ikezoe, Hiroshi; Shikazono, Naomoto; Isoyama, Goro.

    1978-08-01

    A position-sensitive start detector for a time-of-flight measurement is described. In this detector microchannel plates were used to obtain time and position signals simultaneously. A time resolution of 121 psec FWHM and a position resolution of 0.28 mm FWHM were obtained for α-particles from an 241 Am source. (auth.)

  20. Present-day sea level rise: a synthesis

    International Nuclear Information System (INIS)

    Cazenave, A.; Llovel, W.; Lombard, A.

    2008-01-01

    Measuring sea level change and understanding its causes have improved considerably in the recent years, essentially because new in situ and remote sensing data sets have become available. Here we report on the current knowledge of present-day sea level change. We briefly present observational results on sea level change from satellite altimetry since 1993 and tide gauges for the past century. We next discuss recent progress made in quantifying the processes causing sea level change on time scales ranging from years to decades, i.e., thermal expansion, land ice mass loss and land water storage change. For the 1993-2003 decade, the sum of climate-related contributions agree well (within the error bars) with the altimetry-based sea level, half of the observed rate of rise being due to ocean thermal expansion, land ice plus land waters explaining the other half. Since about 2003, thermal expansion increase has stopped, whereas the sea level continues to rise, although at a reduced rate compared to the previous decade (2.5 mm/yr versus 3.1 mm/yr). Recent increases in glacier melting and ice mass loss from the ice sheets appear able to account alone for the rise in sea level reported over the last five years. (authors)

  1. AC loss time constant measurements on Nb3Al and NbTi multifilamentary superconductors

    International Nuclear Information System (INIS)

    Painter, T.A.

    1988-03-01

    The AC loss time constant is a previously univestigated property of Nb 3 Al, a superconductor which, with recent technological developments, shows some advantages over the more commonly used superconductors, NbTi and Nb 3 Sn. Four Nb 3 Al samples with varying twist pitches and one NbTi sample are inductively measured for their AC loss time constants. The measured time constants are compared to the theoretical time constant limits imposed by the limits of the transverse resistivity found by Carr [5] and to the theoretical time constants found using the Bean Model as well as to each other. The measured time constants of the Nb 3 Al samples fall approximately halfway between the theoretical time constant limits, and the measured time constants of the NbTi sample is close to the theoretical lower time constant limit. The Bean Model adequately accounts for the variance of the permeability of the Nb 3 Al superconductor in a background magnetic field. Finally, the measured time constant values of the Nb 3 Al samples vary approximately according to the square of their twist pitch. (author)

  2. Field-measured drag area is a key correlate of level cycling time trial performance

    Directory of Open Access Journals (Sweden)

    James E. Peterman

    2015-08-01

    Full Text Available Drag area (Ad is a primary factor determining aerodynamic resistance during level cycling and is therefore a key determinant of level time trial performance. However, Ad has traditionally been difficult to measure. Our purpose was to determine the value of adding field-measured Ad as a correlate of level cycling time trial performance. In the field, 19 male cyclists performed a level (22.1 km time trial. Separately, field-determined Ad and rolling resistance were calculated for subjects along with projected frontal area assessed directly (AP and indirectly (Est AP. Also, a graded exercise test was performed to determine $\\dot {V}{O}_{2}$V̇O2 peak, lactate threshold (LT, and economy. $\\dot {V}{O}_{2}$V̇O2 peak ($\\mathrm{l}~\\min ^{-1}$lmin−1 and power at LT were significantly correlated to power measured during the time trial (r = 0.83 and 0.69, respectively but were not significantly correlated to performance time (r = − 0.42 and −0.45. The correlation with performance time improved significantly (p < 0.05 when these variables were normalized to Ad. Of note, Ad alone was better correlated to performance time (r = 0.85, p < 0.001 than any combination of non-normalized physiological measure. The best correlate with performance time was field-measured power output during the time trial normalized to Ad (r = − 0.92. AP only accounted for 54% of the variability in Ad. Accordingly, the correlation to performance time was significantly lower using power normalized to AP (r = − 0.75 or Est AP (r = − 0.71. In conclusion, unless normalized to Ad, level time trial performance in the field was not highly correlated to common laboratory measures. Furthermore, our field-measured Ad is easy to determine and was the single best predictor of level time trial performance.

  3. Mini Tensiometer-Time Domain Reflectometry Coil Probe for Measuring Soil Water Retention Properties

    DEFF Research Database (Denmark)

    Subedi, Shaphal; Kawamoto, Ken; Karunarathna, Anurudda Kumara

    2013-01-01

    Time domain reflectometry (TDR) is used widely for measuring soil-water content. New TDR coil probe technology facilitates the development of small, nondestructive probes for simultaneous measurement of soil-water content (θ) and soil-water potential (ψ). In this study we developed mini tensiomet...... between measured soil-water retention curves (ψ > –100 cm H2O) by the new T-TDR coil probes and independent measurements by the hanging water column method....

  4. Optimal distribution of integration time for intensity measurements in degree of linear polarization polarimetry.

    Science.gov (United States)

    Li, Xiaobo; Hu, Haofeng; Liu, Tiegen; Huang, Bingjing; Song, Zhanjie

    2016-04-04

    We consider the degree of linear polarization (DOLP) polarimetry system, which performs two intensity measurements at orthogonal polarization states to estimate DOLP. We show that if the total integration time of intensity measurements is fixed, the variance of the DOLP estimator depends on the distribution of integration time for two intensity measurements. Therefore, by optimizing the distribution of integration time, the variance of the DOLP estimator can be decreased. In this paper, we obtain the closed-form solution of the optimal distribution of integration time in an approximate way by employing Delta method and Lagrange multiplier method. According to the theoretical analyses and real-world experiments, it is shown that the variance of the DOLP estimator can be decreased for any value of DOLP. The method proposed in this paper can effectively decrease the measurement variance and thus statistically improve the measurement accuracy of the polarimetry system.

  5. Optimal distribution of integration time for intensity measurements in Stokes polarimetry.

    Science.gov (United States)

    Li, Xiaobo; Liu, Tiegen; Huang, Bingjing; Song, Zhanjie; Hu, Haofeng

    2015-10-19

    We consider the typical Stokes polarimetry system, which performs four intensity measurements to estimate a Stokes vector. We show that if the total integration time of intensity measurements is fixed, the variance of the Stokes vector estimator depends on the distribution of the integration time at four intensity measurements. Therefore, by optimizing the distribution of integration time, the variance of the Stokes vector estimator can be decreased. In this paper, we obtain the closed-form solution of the optimal distribution of integration time by employing Lagrange multiplier method. According to the theoretical analysis and real-world experiment, it is shown that the total variance of the Stokes vector estimator can be significantly decreased about 40% in the case discussed in this paper. The method proposed in this paper can effectively decrease the measurement variance and thus statistically improves the measurement accuracy of the polarimetric system.

  6. How to statistically analyze nano exposure measurement results: using an ARIMA time series approach

    International Nuclear Information System (INIS)

    Klein Entink, Rinke H.; Fransman, Wouter; Brouwer, Derk H.

    2011-01-01

    Measurement strategies for exposure to nano-sized particles differ from traditional integrated sampling methods for exposure assessment by the use of real-time instruments. The resulting measurement series is a time series, where typically the sequential measurements are not independent from each other but show a pattern of autocorrelation. This article addresses the statistical difficulties when analyzing real-time measurements for exposure assessment to manufactured nano objects. To account for autocorrelation patterns, Autoregressive Integrated Moving Average (ARIMA) models are proposed. A simulation study shows the pitfalls of using a standard t-test and the application of ARIMA models is illustrated with three real-data examples. Some practical suggestions for the data analysis of real-time exposure measurements conclude this article.

  7. Real-time and high accuracy frequency measurements for intermediate frequency narrowband signals

    Science.gov (United States)

    Tian, Jing; Meng, Xiaofeng; Nie, Jing; Lin, Liwei

    2018-01-01

    Real-time and accurate measurements of intermediate frequency signals based on microprocessors are difficult due to the computational complexity and limited time constraints. In this paper, a fast and precise methodology based on the sigma-delta modulator is designed and implemented by first generating the twiddle factors using the designed recursive scheme. This scheme requires zero times of multiplications and only half amounts of addition operations by using the discrete Fourier transform (DFT) and the combination of the Rife algorithm and Fourier coefficient interpolation as compared with conventional methods such as DFT and Fast Fourier Transform. Experimentally, when the sampling frequency is 10 MHz, the real-time frequency measurements with intermediate frequency and narrowband signals have a measurement mean squared error of ±2.4 Hz. Furthermore, a single measurement of the whole system only requires approximately 0.3 s to achieve fast iteration, high precision, and less calculation time.

  8. Using Indirect Turbulence Measurements for Real-Time Parameter Estimation in Turbulent Air

    Science.gov (United States)

    Martos, Borja; Morelli, Eugene A.

    2012-01-01

    The use of indirect turbulence measurements for real-time estimation of parameters in a linear longitudinal dynamics model in atmospheric turbulence was studied. It is shown that measuring the atmospheric turbulence makes it possible to treat the turbulence as a measured explanatory variable in the parameter estimation problem. Commercial off-the-shelf sensors were researched and evaluated, then compared to air data booms. Sources of colored noise in the explanatory variables resulting from typical turbulence measurement techniques were identified and studied. A major source of colored noise in the explanatory variables was identified as frequency dependent upwash and time delay. The resulting upwash and time delay corrections were analyzed and compared to previous time shift dynamic modeling research. Simulation data as well as flight test data in atmospheric turbulence were used to verify the time delay behavior. Recommendations are given for follow on flight research and instrumentation.

  9. Real time drift measurement for colloidal probe atomic force microscope: a visual sensing approach

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yuliang, E-mail: wangyuliang@buaa.edu.cn; Bi, Shusheng [Robotics Institute, School of Mechanical Engineering and Automation, Beihang University, Beijing 100191 (China); Wang, Huimin [Department of Materials Science and Engineering, The Ohio State University, 2041 College Rd., Columbus, OH 43210 (United States)

    2014-05-15

    Drift has long been an issue in atomic force microscope (AFM) systems and limits their ability to make long time period measurements. In this study, a new method is proposed to directly measure and compensate for the drift between AFM cantilevers and sample surfaces in AFM systems. This was achieved by simultaneously measuring z positions for beads at the end of an AFM colloidal probe and on sample surface through an off-focus image processing based visual sensing method. The working principle and system configuration are presented. Experiments were conducted to validate the real time drift measurement and compensation. The implication of the proposed method for regular AFM measurements is discussed. We believe that this technique provides a practical and efficient approach for AFM experiments requiring long time period measurement.

  10. Measuring Physical Inactivity: Do Current Measures Provide an Accurate View of “Sedentary” Video Game Time?

    Directory of Open Access Journals (Sweden)

    Simon Fullerton

    2014-01-01

    Full Text Available Background. Measures of screen time are often used to assess sedentary behaviour. Participation in activity-based video games (exergames can contribute to estimates of screen time, as current practices of measuring it do not consider the growing evidence that playing exergames can provide light to moderate levels of physical activity. This study aimed to determine what proportion of time spent playing video games was actually spent playing exergames. Methods. Data were collected via a cross-sectional telephone survey in South Australia. Participants aged 18 years and above (n=2026 were asked about their video game habits, as well as demographic and socioeconomic factors. In cases where children were in the household, the video game habits of a randomly selected child were also questioned. Results. Overall, 31.3% of adults and 79.9% of children spend at least some time playing video games. Of these, 24.1% of adults and 42.1% of children play exergames, with these types of games accounting for a third of all time that adults spend playing video games and nearly 20% of children’s video game time. Conclusions. A substantial proportion of time that would usually be classified as “sedentary” may actually be spent participating in light to moderate physical activity.

  11. Measurement of Responsibility: A Critical Evaluation of Level of Work Measurement by Time-Span of Discretion.

    Science.gov (United States)

    Laner, S.; And Others

    This report is a critical evaluation based on extended field trials and theoretical analysis of the time-span technique of measuring level of work in organizational hierarchies. It is broadly concluded that the technique does possess many of the desirable features claimed by its originator, but that earlier, less highly structured versions based…

  12. Measuring fragmentation in dissociative identity disorder: the integration measure and relationship to switching and time in therapy.

    Science.gov (United States)

    Barlow, M Rose; Chu, James A

    2014-01-01

    Some people with dissociative identity disorder (DID) have very little communication or awareness among the parts of their identity, while others experience a great deal of cooperation among alternate identities. Previous research on this topic has been sparse. Currently, there is no empirical measure of integration versus fragmentation in a person with DID. In this study, we report the development of such a measure. The goal of this study was to pilot the integration measure (IM) and to address its psychometric properties and relationships to other measures. The IM is the first standardized measure of integration in DID. Eleven women with DID participated in an experiment that included a variety of tasks. They filled out questionnaires about trauma and dissociation as well as the IM. They also provided verbal results about switching among alternate identities during the study sessions. Participants switched among identities an average of 5.8 times during the first session, and switching was highly correlated with trauma. Integration was related to switching, though this relationship may be non-linear. Integration was not related to time in psychotherapy. The IM provides a useful beginning to quantify and study integration and fragmentation in DID. Directions for future research are also discussed, including expanding the IM from this pilot. The IM may be useful in treatment settings to assess progress or change over time.

  13. Measuring fragmentation in dissociative identity disorder: the integration measure and relationship to switching and time in therapy

    Directory of Open Access Journals (Sweden)

    Margaret Rose Barlow

    2014-01-01

    Full Text Available Background: Some people with dissociative identity disorder (DID have very little communication or awareness among the parts of their identity, while others experience a great deal of cooperation among alternate identities. Previous research on this topic has been sparse. Currently, there is no empirical measure of integration versus fragmentation in a person with DID. In this study, we report the development of such a measure. Objective: The goal of this study was to pilot the integration measure (IM and to address its psychometric properties and relationships to other measures. The IM is the first standardized measure of integration in DID. Method: Eleven women with DID participated in an experiment that included a variety of tasks. They filled out questionnaires about trauma and dissociation as well as the IM. They also provided verbal results about switching among alternate identities during the study sessions. Results: Participants switched among identities an average of 5.8 times during the first session, and switching was highly correlated with trauma. Integration was related to switching, though this relationship may be non-linear. Integration was not related to time in psychotherapy. Conclusions: The IM provides a useful beginning to quantify and study integration and fragmentation in DID. Directions for future research are also discussed, including expanding the IM from this pilot. The IM may be useful in treatment settings to assess progress or change over time.

  14. Measurements of electron avalanche formation time in W-band microwave air breakdown

    International Nuclear Information System (INIS)

    Cook, Alan M.; Hummelt, Jason S.; Shapiro, Michael A.; Temkin, Richard J.

    2011-01-01

    We present measurements of formation times of electron avalanche ionization discharges induced by a focused 110 GHz millimeter-wave beam in atmospheric air. Discharges take place in a free volume of gas, with no nearby surfaces or objects. When the incident field amplitude is near the breakdown threshold for pulsed conditions, measured formation times are ∼0.1-2 μs over the pressure range 5-700 Torr. Combined with electric field breakdown threshold measurements, the formation time data shows the agreement of 110 GHz air breakdown with the similarity laws of gas discharges.

  15. Measurements of electron avalanche formation time in W-band microwave air breakdown

    Science.gov (United States)

    Cook, Alan M.; Hummelt, Jason S.; Shapiro, Michael A.; Temkin, Richard J.

    2011-08-01

    We present measurements of formation times of electron avalanche ionization discharges induced by a focused 110 GHz millimeter-wave beam in atmospheric air. Discharges take place in a free volume of gas, with no nearby surfaces or objects. When the incident field amplitude is near the breakdown threshold for pulsed conditions, measured formation times are ˜0.1-2 μs over the pressure range 5-700 Torr. Combined with electric field breakdown threshold measurements, the formation time data shows the agreement of 110 GHz air breakdown with the similarity laws of gas discharges.

  16. A new methodology for measuring time correlations and excite states of atoms and nuclei

    International Nuclear Information System (INIS)

    Cavalcante, M.A.

    1989-01-01

    A system for measuring time correlation of physical phenomena events in the range of 10 -7 to 10 5 sec is proposed, and his results presented. This system, is based on a sequential time scale which is controlled by a precision quartz oscillator; the zero time of observation is set by means of a JK Flip-Flop, which is operated by a negative transition of pulse in coincidence with the pulse from a detector which marks the time zero of the event (precedent pulse). This electronic system (named digital chronoanalizer) was used in the measurement of excited states of nuclei as well as for the determination of time fluctuations in physical phenomena, such as the time lag in a halogen Geiger counter and is the measurement of the 60 KeV excited state of N P 237 . (author)

  17. A statistical model for measurement error that incorporates variation over time in the target measure, with application to nutritional epidemiology.

    Science.gov (United States)

    Freedman, Laurence S; Midthune, Douglas; Dodd, Kevin W; Carroll, Raymond J; Kipnis, Victor

    2015-11-30

    Most statistical methods that adjust analyses for measurement error assume that the target exposure T is a fixed quantity for each individual. However, in many applications, the value of T for an individual varies with time. We develop a model that accounts for such variation, describing the model within the framework of a meta-analysis of validation studies of dietary self-report instruments, where the reference instruments are biomarkers. We demonstrate that in this application, the estimates of the attenuation factor and correlation with true intake, key parameters quantifying the accuracy of the self-report instrument, are sometimes substantially modified under the time-varying exposure model compared with estimates obtained under a traditional fixed-exposure model. We conclude that accounting for the time element in measurement error problems is potentially important. Copyright © 2015 John Wiley & Sons, Ltd.

  18. Method and apparatus for real-time measurement of fuel gas compositions and heating values

    Science.gov (United States)

    Zelepouga, Serguei; Pratapas, John M.; Saveliev, Alexei V.; Jangale, Vilas V.

    2016-03-22

    An exemplary embodiment can be an apparatus for real-time, in situ measurement of gas compositions and heating values. The apparatus includes a near infrared sensor for measuring concentrations of hydrocarbons and carbon dioxide, a mid infrared sensor for measuring concentrations of carbon monoxide and a semiconductor based sensor for measuring concentrations of hydrogen gas. A data processor having a computer program for reducing the effects of cross-sensitivities of the sensors to components other than target components of the sensors is also included. Also provided are corresponding or associated methods for real-time, in situ determination of a composition and heating value of a fuel gas.

  19. In-flight fast-timing measurements in "1"5"2Sm

    International Nuclear Information System (INIS)

    Plaisir, C.; Gaudefroy, L.; Meot, V.; Blanc, A.; Daugas, J.M.; Roig, O.; Arnal, N.; Bonnet, T.; Gobet, F.; Hannachi, F.; Tarisien, M.; Versteegen, M.; Roger, T.; Rejmund, M.; Navin, A.; Schmitt, C.; Fremont, G.; Goupil, J.; Pancin, J.; Spitaels, C.; Zielinska, M.

    2014-01-01

    We report on the first application of in-flight fast-timing measurements, a method developed in order to directly measure lifetimes in the picosecond to nanosecond range. As a proof of principle of the method, lifetimes of the states belonging to the ground-state band in "1"5"2Sm are measured up to the 8"+_1 state. An excellent agreement with recommended values is found. A slightly improved determination of the spectroscopic quadrupole moment of the 4"+_1 state is also reported. In-flight fast-timing measurements open interesting opportunities for future studies of collective properties in radioactive nuclei. (authors)

  20. Accuracy, reproducibility, and time efficiency of dental measurements using different technologies.

    Science.gov (United States)

    Grünheid, Thorsten; Patel, Nishant; De Felippe, Nanci L; Wey, Andrew; Gaillard, Philippe R; Larson, Brent E

    2014-02-01

    Historically, orthodontists have taken dental measurements on plaster models. Technological advances now allow orthodontists to take these measurements on digital models. In this study, we aimed to assess the accuracy, reproducibility, and time efficiency of dental measurements taken on 3 types of digital models. emodels (GeoDigm, Falcon Heights, Minn), SureSmile models (OraMetrix, Richardson, Tex), and AnatoModels (Anatomage, San Jose, Calif) were made for 30 patients. Mesiodistal tooth-width measurements taken on these digital models were timed and compared with those on the corresponding plaster models, which were used as the gold standard. Accuracy and reproducibility were assessed using the Bland-Altman method. Differences in time efficiency were tested for statistical significance with 1-way analysis of variance. Measurements on SureSmile models were the most accurate, followed by those on emodels and AnatoModels. Measurements taken on SureSmile models were also the most reproducible. Measurements taken on SureSmile models and emodels were significantly faster than those taken on AnatoModels and plaster models. Tooth-width measurements on digital models can be as accurate as, and might be more reproducible and significantly faster than, those taken on plaster models. Of the models studied, the SureSmile models provided the best combination of accuracy, reproducibility, and time efficiency of measurement. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  1. Period, epoch, and prediction errors of ephemerides from continuous sets of timing measurements

    Science.gov (United States)

    Deeg, H. J.

    2015-06-01

    Space missions such as Kepler and CoRoT have led to large numbers of eclipse or transit measurements in nearly continuous time series. This paper shows how to obtain the period error in such measurements from a basic linear least-squares fit, and how to correctly derive the timing error in the prediction of future transit or eclipse events. Assuming strict periodicity, a formula for the period error of these time series is derived, σP = σT (12 / (N3-N))1 / 2, where σP is the period error, σT the timing error of a single measurement, and N the number of measurements. Compared to the iterative method for period error estimation by Mighell & Plavchan (2013), this much simpler formula leads to smaller period errors, whose correctness has been verified through simulations. For the prediction of times of future periodic events, usual linear ephemeris were epoch errors are quoted for the first time measurement, are prone to an overestimation of the error of that prediction. This may be avoided by a correction for the duration of the time series. An alternative is the derivation of ephemerides whose reference epoch and epoch error are given for the centre of the time series. For long continuous or near-continuous time series whose acquisition is completed, such central epochs should be the preferred way for the quotation of linear ephemerides. While this work was motivated from the analysis of eclipse timing measures in space-based light curves, it should be applicable to any other problem with an uninterrupted sequence of discrete timings for which the determination of a zero point, of a constant period and of the associated errors is needed.

  2. Determination of Temperature Rise and Temperature Differentials of CEMII/B-V Cement for 20MPa Mass Concrete using Adiabatic Temperature Rise Data

    Science.gov (United States)

    Chee Siang, GO

    2017-07-01

    Experimental test was carried out to determine the temperature rise characteristics of Portland-Fly-Ash Cement (CEM II/B-V, 42.5N) of Blaine fineness 418.6m2/kg and 444.6m2/kg respectively for 20MPa mass concrete under adiabatic condition. The estimation on adiabatic temperature rise by way of CIRIA C660 method (Construction Industry Research & Information Information) was adopted to verify and validate the hot-box test results by simulating the heat generation curve of the concrete under semi-adiabatic condition. Test result found that Portland fly-ash cement has exhibited decrease in the peak value of temperature rise and maximum temperature rise rate. The result showed that the temperature development and distribution profile, which is directly contributed from the heat of hydration of cement with time, is affected by the insulation, initial placing temperature, geometry and size of concrete mass. The mock up data showing the measured temperature differential is significantly lower than the technical specifications 20°C temperature differential requirement and the 27.7°C limiting temperature differential for granite aggregate concrete as stipulated in BS8110-2: 1985. The concrete strength test result revealed that the 28 days cubes compressive strength was above the stipulated 20MPa characteristic strength at 90 days. The test demonstrated that with proper concrete mix design, the use of Portland flyash cement, combination of chilled water and flake ice, and good insulation is effective in reducing peak temperature rise, temperature differential, and lower adiabatic temperature rise for mass concrete pours. As far as the determined adiabatic temperature rise result was concern, the established result could be inferred for in-situ thermal properties of 20MPa mass concrete application, as the result could be repeatable on account of similar type of constituent materials and concrete mix design adopted for permanent works at project site.

  3. Commercial border crossing and wait time measurement at the Pharr-Reynosa International Bridge.

    Science.gov (United States)

    2010-11-01

    The objective of the research described in this report is to install and implement radio frequency : identification (RFID) technology to measure border crossing time and travel delay for : commercial trucks crossing from Mexico into Texas at the Phar...

  4. Online evolution reconstruction from a single measurement record with random time intervals for quantum communication

    Science.gov (United States)

    Zhou, Hua; Su, Yang; Wang, Rong; Zhu, Yong; Shen, Huiping; Pu, Tao; Wu, Chuanxin; Zhao, Jiyong; Zhang, Baofu; Xu, Zhiyong

    2017-10-01

    Online reconstruction of a time-variant quantum state from the encoding/decoding results of quantum communication is addressed by developing a method of evolution reconstruction from a single measurement record with random time intervals. A time-variant two-dimensional state is reconstructed on the basis of recovering its expectation value functions of three nonorthogonal projectors from a random single measurement record, which is composed from the discarded qubits of the six-state protocol. The simulated results prove that our method is robust to typical metro quantum channels. Our work extends the Fourier-based method of evolution reconstruction from the version for a regular single measurement record with equal time intervals to a unified one, which can be applied to arbitrary single measurement records. The proposed protocol of evolution reconstruction runs concurrently with the one of quantum communication, which can facilitate the online quantum tomography.

  5. Determination of rail wear and short-time wear measurements of rails applying radioisotopes

    International Nuclear Information System (INIS)

    Grohmann, H.D.

    1981-01-01

    An energetic model has been developed for calculating rail wear. Short-time wear tests on rails after surface activation and following activity measurements showed a good agreement with the calculated values

  6. Time-integrated CP violation measurements in the B mesons system at the LHCb experiment

    CERN Document Server

    Cardinale, R

    2016-01-01

    Time-integrated CP violation measurements in the B meson system provide information for testing the CKM picture of CP violation in the Standard Model. A review of recent results from the LHCb experiment is presented.

  7. Time-of-flight techniques applied to neutron spectra measurements in fast subcritical assemblies

    International Nuclear Information System (INIS)

    Rotival, Michel

    1975-04-01

    Time-of-flight measurements on Uranium-Graphite assemblies were performed using the BCMN linear accelerator. Methods to provide scalar spectra averaged over a core cell from these experimental results are described [fr

  8. Analog measurement of delayed antiproton annihilation time spectra in a high intensity pulsed antiproton beam

    International Nuclear Information System (INIS)

    Niestroj, A.; Hayano, R.S.; Ishikawa, T.; Tamura, H.; Torii, H.A.; Morita, N.; Yamazaki, T.; Sugai, I.; Nakayoshi, K.; Horvath, D.; Eades, J.; Widmann, E.

    1996-01-01

    An analog detection system has been developed to measure delayed antiproton annihilation time spectra for laser resonance spectroscopy of metastable antiprotonic helium atoms using the high-intensity pulsed beam of antiprotons from LEAR at CERN. (orig.)

  9. Surface-Borne Time-of-Reception Measurements (STORM), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Invocon proposes the Surface-borne Time-Of-Reception Measurements (STORM) system as a method to locate the position of lightning strikes on aerospace vehicles....

  10. Method for simultaneous measurement of borehole and formation neutron decay-times employing iterative fitting

    International Nuclear Information System (INIS)

    Schultz, W.E.

    1982-01-01

    A method is described of making in situ measurements of the thermal neutron decay time of earth formations in the vicinity of a wellbore. The borehole and earth formations in its vicinity are repetitively irradiated with pulsed fast neutrons and, during the intervals between pulses, capture gamma radiation is measured in at least four, non-overlapping, contiguous time intervals. A background radiation measurement is made between successive pulses and used to correct count-rates representative of thermal neutron populations in the borehole and the formations, the count-rates being generated during each of the time intervals. The background-corrected count-rate measurements are iteratively fitted to exponential curves using a least squares technique to simultaneously derive signals representing borehole component and formation component of the thermal neutron decay time. The signals are recorded as a function of borehole depth. (author)

  11. Travel time data collection for measurement of advanced traveler information systems accuracy

    Science.gov (United States)

    2003-06-01

    The objective of this white paper is to recommend an approach to measuring ATIS travel time accuracy so that ITS planners might have the data they need to make cost effective decisions regarding deployment of surveillance technologies to support ATIS...

  12. Comparison of methods for measuring travel time at Florida freeways and arterials : [summary].

    Science.gov (United States)

    2014-07-01

    In this project, University of Florida researchers : collected field data along several highways to : evaluate travel time measurements from several : sources: STEWARD, BlueTOAD, INRIX, and HERE. : STEWARD (Statewide Transportation Engineering : Ware...

  13. Efficacy of New Measures Saving Time in Acute Stroke Management: A Quantified Analysis.

    Science.gov (United States)

    Iglesias Mohedano, Ana María; García Pastor, Andrés; Díaz Otero, Fernando; Vázquez Alen, Pilar; Vales Montero, Marta; Luque Buzo, Elisa; Redondo Ráfales, Nuria; Chavarria Cano, Beatriz; Fernández Bullido, Yolanda; Villanueva Osorio, Jose Antonio; Gil Núñez, Antonio

    2017-08-01

    Time to treatment remains the most important factor in acute ischemic stroke prognosis. We quantified the effect of new interventions reducing in-hospital delays in acute stroke management and assessed its repercussion on door-to-imaging (DTI), imaging-to-needle (ITN), and door-to-needle (DTN) times. Prospective registry of consecutive stroke patients who were candidates for reperfusion therapy attended in a tertiary care hospital from February 1 to December 31, 2014. A series of measures aimed at reducing in-hospital delays were implemented. We compared DTI, ITN, and DTN times between patients who underwent the interventions and those who did not. 231 patients. DTI time was lower when personal history was reviewed and tests were ordered before patient arrival (2.5 minutes saved, P = .016) and when electrocardiogram was not made (5.4 minutes saved, P time significantly (14 and 12 minutes saved, respectively, P time. Completing all steps resulted in the lowest DTI and ITN times (13 and 19 minutes, respectively). Every measure is an important part of a chain focused on saving time in acute stroke: the lowest DTI and ITN times were obtained when all steps were completed. Measures shortening ITN time produced a greater impact on DTN time reduction; therefore, ITN interventions should be considered a critical part of new protocols and guidelines. Copyright © 2017. Published by Elsevier Inc.

  14. Experimental demonstration of the finite measurement time effect on the Feynman-{alpha} technique

    Energy Technology Data Exchange (ETDEWEB)

    Wallerbos, E.J.M.; Hoogenboom, J.E

    1998-09-01

    The reactivity of a subcritical system is determined by fitting two different theoretical models to a measured Feynman-{alpha} curve. The first model is the expression usually found in the literature, which can be shown to be the expectation value of the experimental quality if the measurement time is infinite. The second model is a new expression which is the expectation value of the experimental quantity for a finite measurement time. The reactivity inferred with the new model is seen to be independent of the length of the fitting interval, whereas the reactivity inferred with the conventional model is seen to vary. This difference demonstrates the effect of the finite measurement time. As a reference, the reactivity is also measured with the pulsed-neutron source method. It is seen to be in good agreement with the reactivity obtained with the Feynman-{alpha} technique when the new expression is applied.

  15. A new method for measuring the response time of the high pressure ionization chamber

    International Nuclear Information System (INIS)

    Wang, Zhentao; Shen, Yixiong; An, Jigang

    2012-01-01

    Time response is an important performance characteristic for gas-pressurized ionization chambers. To study the time response, it is especially crucial to measure the ion drift time in high pressure ionization chambers. In this paper, a new approach is proposed to study the ion drift time in high pressure ionization chambers. It is carried out with a short-pulsed X-ray source and a high-speed digitizer. The ion drift time in the chamber is then determined from the digitized data. By measuring the ion drift time of a 15 atm xenon testing chamber, the method has been proven to be effective in the time response studies of ionization chambers. - Highlights: ► A method for measuring response time of high pressure ionization chamber is proposed. ► A pulsed X-ray producer and a digital oscilloscope are used in the method. ► The response time of a 15 atm Xenon testing ionization chamber has been measured. ► The method has been proved to be simple, feasible and effective.

  16. Time-resolved measurements of supersonic fuel sprays using synchrotron x-rays

    International Nuclear Information System (INIS)

    Powell, C.F.; Yue, Y.; Poola, R.; Wang, J.

    2000-11-01

    A time-resolved radiographic technique has been developed for probing the fuel distribution close to the nozzle of a high-pressure single-hole diesel injector. The measurement was made using X-ray absorption of monochromatic synchrotron-generated radiation, allowing quantitative determination of the fuel distribution in this optically impenetrable region with a time resolution of better than 1 μs. These quantitative measurements constitute the most detailed near-nozzle study of a fuel spray to date

  17. Time-resolved measurements of supersonic fuel sprays using synchrotron X-rays.

    Science.gov (United States)

    Powell, C F; Yue, Y; Poola, R; Wang, J

    2000-11-01

    A time-resolved radiographic technique has been developed for probing the fuel distribution close to the nozzle of a high-pressure single-hole diesel injector. The measurement was made using X-ray absorption of monochromatic synchrotron-generated radiation, allowing quantitative determination of the fuel distribution in this optically impenetrable region with a time resolution of better than 1 micros. These quantitative measurements constitute the most detailed near-nozzle study of a fuel spray to date.

  18. The influence of measurement and relaxation time on flux jumps in high temperature superconductors

    International Nuclear Information System (INIS)

    Yang Xiaobin; Zhou Youhe; Tu Shandong

    2010-01-01

    The influence of the magnetization and relaxation time on flux jumps in high temperature superconductors (HTSC) under varying magnetic field is studied using the fundamental electromagnetic field equations and the thermal diffusion equation; temperature variety corresponding to flux jump is also discussed. We find that for a low sweep rate of the applied magnetic field, the measurement and relaxation times can reduce flux jump and to constrain the number of flux jumps, even stabilizing the HTSC, since much heat produced by the motion of magnetic flux can transfer into coolant during the measurement and relaxation times. As high temperature superconductors are subjected to a high sweep rate or a strong pulsed magnetic field, magnetization undergoes from stability or oscillation to jump for different pause times. And the period of temperature oscillation is equal to the measurement and relaxation time.

  19. On the measurement of the neutrino velocity applying the standard time of the Global Positioning System

    International Nuclear Information System (INIS)

    Skeivalas, J; Parseliunas, E

    2013-01-01

    The measurement of the neutrino velocity applying the standard time of the Global Positioning System (GPS) is presented in the paper. The practical data were taken from the OPERA experiment, in which neutrino emission from the CERN LHC accelerator to Gran Sasso detector was investigated. The distance between accelerator and detector is about 730 km. The time interval was measured by benchmark clocks, which were calibrated by the standard GPS time signals received from GPS satellites. The calculation of the accuracy of the GPS time signals with respect to changes of the signals' frequencies due to the Doppler effect is presented. It is shown that a maximum error of about 200 ns could occur when GPS time signals are applied for the calibration of the clocks for the neutrino velocity measurements. (paper)

  20. Improved measurement linearity and precision for AMCW time-of-flight range imaging cameras.

    Science.gov (United States)

    Payne, Andrew D; Dorrington, Adrian A; Cree, Michael J; Carnegie, Dale A

    2010-08-10

    Time-of-flight range imaging systems utilizing the amplitude modulated continuous wave (AMCW) technique often suffer from measurement nonlinearity due to the presence of aliased harmonics within the amplitude modulation signals. Typically a calibration is performed to correct these errors. We demonstrate an alternative phase encoding approach that attenuates the harmonics during the sampling process, thereby improving measurement linearity in the raw measurements. This mitigates the need to measure the system's response or calibrate for environmental changes. In conjunction with improved linearity, we demonstrate that measurement precision can also be increased by reducing the duty cycle of the amplitude modulated illumination source (while maintaining overall illumination power).

  1. Measuring quality indicators in the operating room: cleaning and turnover time.

    Science.gov (United States)

    Jericó, Marli de Carvalho; Perroca, Márcia Galan; da Penha, Vivian Colombo

    2011-01-01

    This exploratory-descriptive study was carried out in the Surgical Center Unit of a university hospital aiming to measure time spent with concurrent cleaning performed by the cleaning service and turnover time and also investigated potential associations between cleaning time and the surgery's magnitude and specialty, period of the day and the room's size. The sample consisted of 101 surgeries, computing cleaning time and 60 surgeries, computing turnover time. The Kaplan-Meier method was used to analyze time and Pearson's correlation to study potential correlations. The time spent in concurrent cleaning was 7.1 minutes and turnover time was 35.6 minutes. No association between cleaning time and the other variables was found. These findings can support nurses in the efficient use of resources thereby speeding up the work process in the operating room.

  2. Measuring small time periods in earth sciences by uranium series disequilibrium

    International Nuclear Information System (INIS)

    Choudhary, A.K.

    2008-01-01

    During the last three decades mass spectrometry in India has seen its application in almost every field of science. In particular, TIMS has revolutionized geological sciences by taking it from a mainly descriptive to modern quantitative Earth Sciences. It has largely contributed in measurement of precise time scales of geological processes. During the last decade, focus has primarily been on measurement of time scales of these fundamental processes. Some of the radiometric methods initially developed for measuring shorter time-scales have their own problems. The intermediate nuclides in the uranium and thorium decay series having much shorter half lives compared to their parents, provide a useful tool to measure intermediate time scales. These isotopes had earlier been ignored due to analytical difficulties associated with their measurement. The development of new generation mass spectrometers with very high abundance sensitivity has now made it possible to measure these isotopic ratios. Consequently U-series isotopic measurements have put unique and at times the only quantitative constraints on the processes taking place in the interior of the Earth. Since such mass spectrometers have recently been installed in some of the laboratories in India, scientific investigation may now be taken up in some of the unexplored areas of Earth Sciences in our country

  3. Remote Monitoring of the Heart Condition of Athletes by Measuring the Cardiac Action Potential Propagation Time Using a Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    Amang Sudarsono

    2016-04-01

    Full Text Available Highly performing athletes are susceptible to cardiac damage of several kinds which may be irreversible. The monitoring of heart rate and ECG waveforms from such subjects by wireless sensor networks has been reported in health and sports care documents. However, a more decisive parameter for instant to instant changes would be the time of Cardiac Action Potential Propagation. This time, which can be between 15-20 ms would shoot suddenly in acute stress in highly performing athletes for short durations. Repeated incidents of such rising values will tend to cause irreversible damage to the heart. We developed the technique of measuring this time and reporting it through a wireless sensor network to monitoring station.

  4. The Rise of Blog Nation

    Science.gov (United States)

    Lum, Lydia

    2005-01-01

    This article reports on the growth of blogs in popular culture, and the fact that they are becoming more widely accepted in the media industry. The rise and popularity of blogs--short for "Web logs"--are causing journalism educators to overhaul their teachings. In fact, blogging's influence varies from one university program to the next, just like…

  5. Measuring Quality Improvement in Acute Ischemic Stroke Care: Interrupted Time Series Analysis of Door-to-Needle Time

    Directory of Open Access Journals (Sweden)

    Anne Margreet van Dishoeck

    2014-06-01

    Full Text Available Background: In patients with acute ischemic stroke, early treatment with recombinant tissue plasminogen activator (rtPA improves functional outcome by effectively reducing disability and dependency. Timely thrombolysis, within 1 h, is a vital aspect of acute stroke treatment, and is reflected in the widely used performance indicator ‘door-to-needle time' (DNT. DNT measures the time from the moment the patient enters the emergency department until he/she receives intravenous rtPA. The purpose of the study was to measure quality improvement from the first implementation of thrombolysis in stroke patients in a university hospital in the Netherlands. We further aimed to identify specific interventions that affect DNT. Methods: We included all patients with acute ischemic stroke consecutively admitted to a large university hospital in the Netherlands between January 2006 and December 2012, and focused on those treated with thrombolytic therapy on admission. Data were collected routinely for research purposes and internal quality measurement (the Erasmus Stroke Study. We used a retrospective interrupted time series design to study the trend in DNT, analyzed by means of segmented regression. Results: Between January 2006 and December 2012, 1,703 patients with ischemic stroke were admitted and 262 (17% were treated with rtPA. Patients treated with thrombolysis were on average 63 years old at the time of the stroke and 52% were male. Mean age (p = 0.58 and sex distribution (p = 0.98 did not change over the years. The proportion treated with thrombolysis increased from 5% in 2006 to 22% in 2012. In 2006, none of the patients were treated within 1 h. In 2012, this had increased to 81%. In a logistic regression analysis, this trend was significant (OR 1.6 per year, CI 1.4-1.8. The median DNT was reduced from 75 min in 2006 to 45 min in 2012 (p Conclusion and Implications: The DNT steadily improved from the first implementation of thrombolysis. Specific

  6. Real-Time Inhibitor Recession Measurements in the Space Shuttle Reusable Solid Rocket Motors

    Science.gov (United States)

    McWhorter, Bruce B.; Ewing, Mark E.; McCool, Alex (Technical Monitor)

    2001-01-01

    Real-time char line recession measurements were made on propellant inhibitors of the Space Shuttle Reusable Solid Rocket Motor (RSRM). The RSRM FSM-8 static test motor propellant inhibitors (composed of a rubber insulation material) were successfully instrumented with eroding potentiometers and thermocouples. The data was used to establish inhibitor recession versus time relationships. Normally, pre-fire and post-fire insulation thickness measurements establish the thermal performance of an ablating insulation material. However, post-fire inhibitor decomposition and recession measurements are complicated by the fact that most of the inhibitor is back during motor operation. It is therefore a difficult task to evaluate the thermal protection offered by the inhibitor material. Real-time measurements would help this task. The instrumentation program for this static test motor marks the first time that real-time inhibitors. This report presents that data for the center and aft field joint forward facing inhibitors. The data was primarily used to measure char line recession of the forward face of the inhibitors which provides inhibitor thickness reduction versus time data. The data was also used to estimate the inhibitor height versus time relationship during motor operation.

  7. [Pigment dispersion and Artisan implants: crystalline lens rise as a safety criterion].

    Science.gov (United States)

    Baikoff, G; Bourgeon, G; Jodai, H Jitsuo; Fontaine, A; Vieira Lellis, F; Trinquet, L

    2005-06-01

    To validate the theoretical notion of a crystalline lens rise as a safety criterion for ARTISAN implants in order to prevent the development of pigment dispersion in the implanted eye. Crystalline lens rise is defined by the distance between the crystalline lens's anterior pole and the horizontal plane joining the opposite iridocorneal recesses. We analyzed the biometric measurements of 87 eyes with an Artisan implant. A comparative analysis of the crystalline lens rise was carried out on the nine eyes having developed pigment dispersion and 78 eyes with no problems. Among the modern anterior segment imaging devices (Artemis, Scheimpflug photography, optical coherence tomography, radiology exploration, magnetic resonance imaging, TDM), an anterior chamber optical coherence tomography (AC-OCT) prototype was used. This working hypothesis was confirmed by this study: the crystalline lens rise must be considered as a new safety criterion for implanting Artisan phakic lenses. Indeed, the higher the crystalline lens's rise, the greater the risk of developing pigment dispersion in the pupil area. This complication is more frequent in hyperopes than in myopes. We can consider that there is little or no risk of pigment dispersion if the rise is below 600 microm; however, at 600 microm or greater, there is a 67% rate of pupillary pigment dispersion. In certain cases, when the implant was loosely fixed, there was no traction on the iris root. This is a complication that can be avoided or delayed. The crystalline lens rise must be part of new safety criteria to be taken into consideration when inserting an Artisan implant. This notion must also be applied to other types of phakic implants. The distance remaining between the crystalline lens rise and a 600-micromm theoretical safety level allows one to calculate a safety time interval.

  8. Contributed Review: Source-localization algorithms and applications using time of arrival and time difference of arrival measurements

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xinya [Energy and Environment Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352, USA; Deng, Zhiqun Daniel [Energy and Environment Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352, USA; Rauchenstein, Lynn T. [Energy and Environment Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352, USA; Carlson, Thomas J. [Energy and Environment Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352, USA

    2016-04-01

    Locating the position of fixed or mobile sources (i.e., transmitters) based on received measurements from sensors is an important research area that is attracting much research interest. In this paper, we present localization algorithms using time of arrivals (TOA) and time difference of arrivals (TDOA) to achieve high accuracy under line-of-sight conditions. The circular (TOA) and hyperbolic (TDOA) location systems both use nonlinear equations that relate the locations of the sensors and tracked objects. These nonlinear equations can develop accuracy challenges because of the existence of measurement errors and efficiency challenges that lead to high computational burdens. Least squares-based and maximum likelihood-based algorithms have become the most popular categories of location estimators. We also summarize the advantages and disadvantages of various positioning algorithms. By improving measurement techniques and localization algorithms, localization applications can be extended into the signal-processing-related domains of radar, sonar, the Global Positioning System, wireless sensor networks, underwater animal tracking, mobile communications, and multimedia.

  9. Time resolved Thomson scattering measurements on a high pressure mercury lamp

    NARCIS (Netherlands)

    Vries, de N.; Zhu, Xiao-Yan; Kieft, E.R.; Mullen, van der J.J.A.M.

    2005-01-01

    Time resolved Thomson scattering (TS) measurements have been performed on an ac driven high pressure mercury lamp. For this high intensity discharge (HID) lamp, TS is coherent and a coherent fitting routine, including rotational Raman calibration, was used to determine ne and Te from the measured

  10. Measuring Levels of Work in Academic Libraries: A Time Based Approach.

    Science.gov (United States)

    Gould, Donald P.

    1985-01-01

    Using Stratified Systems Theory, which focuses on the manager-subordinate relationship in the bureaucratic structure, a study was conducted to measure level of responsibility in work of 37 professional and nonprofessional positions in four academic library technical services departments. Three levels of work were measured in "time-spans of…

  11. Measurement Invariance of a Summative Achievement Assessment over Time: Is Status Really Ready for Growth?

    Science.gov (United States)

    Viger, Steven Guy

    2014-01-01

    The current study investigates the phenomenon of measurement invariance by examining the construct stability of a summative mathematics achievement instrument over time gleaned from an existing data set. In doing so, not only is the general question of measurement invariance of the particular instrument addressed, but also in the context of growth…

  12. A time-dependent measurement of charm CP violation at LHCb

    CERN Multimedia

    Smith, M

    2014-01-01

    A time dependent analysis of CP violation in charm mesons is presented through the measurement of the observable $A_{\\Gamma}$. This observable involves precise measurements of the D0 lifetime as it decays to a CP eigenstate. The results presented are the most precise to date. No CP violation is observed.

  13. Contributed Review: Source-localization algorithms and applications using time of arrival and time difference of arrival measurements

    Science.gov (United States)

    Li, Xinya; Deng, Zhiqun Daniel; Rauchenstein, Lynn T.; Carlson, Thomas J.

    2016-04-01

    Locating the position of fixed or mobile sources (i.e., transmitters) based on measurements obtained from sensors (i.e., receivers) is an important research area that is attracting much interest. In this paper, we review several representative localization algorithms that use time of arrivals (TOAs) and time difference of arrivals (TDOAs) to achieve high signal source position estimation accuracy when a transmitter is in the line-of-sight of a receiver. Circular (TOA) and hyperbolic (TDOA) position estimation approaches both use nonlinear equations that relate the known locations of receivers and unknown locations of transmitters. Estimation of the location of transmitters using the standard nonlinear equations may not be very accurate because of receiver location errors, receiver measurement errors, and computational efficiency challenges that result in high computational burdens. Least squares and maximum likelihood based algorithms have become the most popular computational approaches to transmitter location estimation. In this paper, we summarize the computational characteristics and position estimation accuracies of various positioning algorithms. By improving methods for estimating the time-of-arrival of transmissions at receivers and transmitter location estimation algorithms, transmitter location estimation may be applied across a range of applications and technologies such as radar, sonar, the Global Positioning System, wireless sensor networks, underwater animal tracking, mobile communications, and multimedia.

  14. The Import of the Cortisol Rise in Child Care Differs as a Function of Behavioral Inhibition

    Science.gov (United States)

    Gunnar, Megan R.; Kryzer, Erin; Van Ryzin, Mark J.; Phillips, Deborah A.

    2011-01-01

    Children of ages 3 to 4.5 years (N = 107; 45 boys, 62 girls) were studied twice, 6 months apart, to examine whether the cortisol rise in child care at Time 1 (T1) was associated with (a) changes in anxious, vigilant behavior from T1 to Time 2 (T2) and (b) higher internalizing symptoms at T2. Controlling for measures of home environment and child…

  15. Demographic correlates of screen time and objectively measured sedentary time and physical activity among toddlers: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Valerie Carson

    2017-02-01

    Full Text Available Abstract Background Determining the most important demographic correlates of sedentary behavior and physical activity will help identify the groups of children that are most in need of intervention. Little is known in regards to the demographic correlates of sedentary behavior and physical activity in toddlers (aged 12–35 months, where long-term behavioral patterns may initially be formed. Therefore, the objective of this study was to examine the associations between demographic correlates and specific types of sedentary behavior and physical activity in this age group. Methods Findings are based on 149 toddlers (19.0 ± 1.9 months and their parents (33.7 ± 4.7 years recruited from immunization clinics in Edmonton, Canada as part of the Parents’ Role in Establishing healthy Physical activity and Sedentary behavior habits (PREPS project. Toddlers’ and parental demographic characteristics and toddlers’ television viewing, video/computer games, and overall screen time were measured via the PREPS parental questionnaire. Toddlers’ objectively measured sedentary time and physical activity (light, moderate to vigorous, and total were accelerometer-derived using Actigraph wGT3X-BT monitors. Simple and multiple linear regression models were conducted to examine associations. Results In the multiple linear regression models, toddlers’ age, toddlers’ sex (female versus male, toddlers’ race/ethnicity (other versus European-Canadian/Caucasian, and household income ($50,001 to $100,000 versus > $100,000 were significantly positively associated, and main type of child care (child care center versus parental care was significantly negatively associated with screen time. Similar findings were observed with television viewing, except null associations were observed for toddlers’ sex. Toddlers’ race/ethnicity (other versus European-Canadian/Caucasian was significantly positively associated and main type of child care (child care

  16. In vivo bleeding time and in vitro thrombelastography measurements are better indicators of dilutional hypothermic coagulopathy than prothrombin time.

    Science.gov (United States)

    Kheirabadi, Bijan S; Crissey, Jacqueline M; Deguzman, Rodolfo; Holcomb, John B

    2007-06-01

    The coagulopathy of trauma is generally confirmed by prothrombin time (PT) > or =16 seconds or an international normalized ratio > or =1.5. However, the utility of these values as a screening test is unknown. We examined different coagulation tests to determine the best predictor of coagulopathic bleeding and mortality in a small animal hemorrhage model. Coagulopathy was induced in male New Zealand White rabbits by warfarin (W; 2 mg/kg for 2 days; n = 7), or hemodilution and hypothermia (HH; 50% blood exchange with Hextend, 34.5 +/- 0.3 degrees C; n = 7). Normal (N) rabbits without pretreatment served as the control (n = 7). Blood samples collected after coagulopathy induction and analyzed by prothrombin time (PT), activated partial thromboplastin time (aPTT), and thromboelastography (TEG) tests. Liver bleeding time (BT) was also measured before injury. An uncontrolled hemorrhage was created by a longitudinal splenic incision and the abdomen was closed. Rabbits were resuscitated with Hextend solution (25 mL/kg) to return blood pressure to baseline and monitored for 2 hours or until death at which time blood loss was measured. Warfarin-induced coagulopathy increased BT, PT, and aPTT. TEG showed increased reaction (R) and clot formation (K) times and marked decrease in clotting rate (alpha angle and Vmax). Hemodilution hypothermia coagulopathy increased only BT and aPTT, and decreased the clotting rate (alpha angle and Vmax) and strength of the clot. After injury, blood losses were higher in coagulopathic rabbits (W = 54.6 +/- 4.2 and HH = 51.1 +/- 8.9 mL/kg) than in normal rabbits (30.6 +/- 12.4 mL/kg) and resulted in 86%, 100%, and 0% death, respectively. BT and Vmax consistently predicted coagulopathic bleeding and death in all animals. Although satisfactory in warfarin-induced coagulopathy, PT was not a valid screening test for dilutional and hypothermic coagulopathy. BT and TEG measurements of blood clotting rate are better indicators of coagulopathic bleeding

  17. The social values at risk from sea-level rise

    International Nuclear Information System (INIS)

    Graham, Sonia; Barnett, Jon; Fincher, Ruth; Hurlimann, Anna; Mortreux, Colette; Waters, Elissa

    2013-01-01

    Analysis of the risks of sea-level rise favours conventionally measured metrics such as the area of land that may be subsumed, the numbers of properties at risk, and the capital values of assets at risk. Despite this, it is clear that there exist many less material but no less important values at risk from sea-level rise. This paper re-theorises these multifarious social values at risk from sea-level rise, by explaining their diverse nature, and grounding them in the everyday practices of people living in coastal places. It is informed by a review and analysis of research on social values from within the fields of social impact assessment, human geography, psychology, decision analysis, and climate change adaptation. From this we propose that it is the ‘lived values’ of coastal places that are most at risk from sea-level rise. We then offer a framework that groups these lived values into five types: those that are physiological in nature, and those that relate to issues of security, belonging, esteem, and self-actualisation. This framework of lived values at risk from sea-level rise can guide empirical research investigating the social impacts of sea-level rise, as well as the impacts of actions to adapt to sea-level rise. It also offers a basis for identifying the distribution of related social outcomes across populations exposed to sea-level rise or sea-level rise policies

  18. The social values at risk from sea-level rise

    Energy Technology Data Exchange (ETDEWEB)

    Graham, Sonia, E-mail: sonia.graham@unimelb.edu.au [Department of Resource Management and Geography, The University of Melbourne, 221 Bouverie St., Carlton, Victoria 3053 (Australia); Barnett, Jon, E-mail: jbarn@unimelb.edu.au [Department of Resource Management and Geography, The University of Melbourne, 221 Bouverie St., Carlton, Victoria 3053 (Australia); Fincher, Ruth, E-mail: r.fincher@unimelb.edu.au [Department of Resource Management and Geography, The University of Melbourne, 221 Bouverie St., Carlton, Victoria 3053 (Australia); Hurlimann, Anna, E-mail: anna.hurlimann@unimelb.edu.au [Faculty of Architecture, Building and Planning, The University of Melbourne, Architecture and Planning Building, Parkville, Victoria 3010 (Australia); Mortreux, Colette, E-mail: colettem@unimelb.edu.au [Department of Resource Management and Geography, The University of Melbourne, 221 Bouverie St., Carlton, Victoria 3053 (Australia); Waters, Elissa, E-mail: elissa.waters@unimelb.edu.au [Department of Resource Management and Geography, The University of Melbourne, 221 Bouverie St., Carlton, Victoria 3053 (Australia)

    2013-07-15

    Analysis of the risks of sea-level rise favours conventionally measured metrics such as the area of land that may be subsumed, the numbers of properties at risk, and the capital values of assets at risk. Despite this, it is clear that there exist many less material but no less important values at risk from sea-level rise. This paper re-theorises these multifarious social values at risk from sea-level rise, by explaining their diverse nature, and grounding them in the everyday practices of people living in coastal places. It is informed by a review and analysis of research on social values from within the fields of social impact assessment, human geography, psychology, decision analysis, and climate change adaptation. From this we propose that it is the ‘lived values’ of coastal places that are most at risk from sea-level rise. We then offer a framework that groups these lived values into five types: those that are physiological in nature, and those that relate to issues of security, belonging, esteem, and self-actualisation. This framework of lived values at risk from sea-level rise can guide empirical research investigating the social impacts of sea-level rise, as well as the impacts of actions to adapt to sea-level rise. It also offers a basis for identifying the distribution of related social outcomes across populations exposed to sea-level rise or sea-level rise policies.

  19. Estimating the Persistence and the Autocorrelation Function of a Time Series that is Measured with Error

    DEFF Research Database (Denmark)

    Hansen, Peter Reinhard; Lunde, Asger

    2014-01-01

    An economic time series can often be viewed as a noisy proxy for an underlying economic variable. Measurement errors will influence the dynamic properties of the observed process and may conceal the persistence of the underlying time series. In this paper we develop instrumental variable (IV...

  20. Measurement of the time of storage of ultracold neutrons in a magnetic trap

    International Nuclear Information System (INIS)

    Abov, Y.G.; Borovlev, S.P.; Vasil'ev, V.V.; Vladimirskii, V.V.; Mospan, E.N.

    1983-01-01

    The storage time of ultracold neutrons in an axial magnetic trap with a simple singly connected confinement region is measured. It is shown that the storage of the neutrons is due just to the magnetic field. The storage time achieved is tau = 303 +- 37 sec. In a working cycle 3.6 neutrons are accumulated

  1. On-chip Brownian relaxation measurements of magnetic nanobeads in the time domain

    DEFF Research Database (Denmark)

    Østerberg, Frederik Westergaard; Rizzi, Giovanni; Hansen, Mikkel Fougt

    2013-01-01

    the time and frequency domain methods on Brownian relaxation detection of clustering of streptavidin coated magnetic beads in the presence of different concentrations of biotin-conjugated bovine serum albumin and obtain comparable results. In the time domain, a measurement is carried out in less than 30 s...

  2. DCE-PWI 3D T1-measurement as function of time or flip angle

    DEFF Research Database (Denmark)

    Mikkelsen, Irene Klærke; Peters, David Alberg; Tietze, Anna

    saturation) time [1,2]. This work investigates how off-set in flip angles in the presence of B1 inhomogeneities propagates into large errors in the T1 estimates. The errors are markedly reduced when the measurement is performed as a function of time, however this requires signal preparation....

  3. Work measurement for estimating food preparation time of a bioregenerative diet

    Science.gov (United States)

    Olabi, Ammar; Hunter, Jean; Jackson, Peter; Segal, Michele; Spies, Rupert; Wang, Carolyn; Lau, Christina; Ong, Christopher; Alexander, Conor; Raskob, Evan; hide

    2003-01-01

    During space missions, such as the prospective Mars mission, crew labor time is a strictly limited resource. The diet for such a mission (based on crops grown in a bioregenerative life support system) will require astronauts to prepare their meals essentially from raw ingredients. Time spent on food processing and preparation is time lost for other purposes. Recipe design and diet planning for a space mission should therefore incorporate the time required to prepare the recipes as a critical factor. In this study, videotape analysis of an experienced chef was used to develop a database of recipe preparation time. The measurements were highly consistent among different measurement teams. Data analysis revealed a wide variation between the active times of different recipes, underscoring the need for optimization of diet planning. Potential uses of the database developed in this study are discussed and illustrated in this work.

  4. Automatic detection of health changes using statistical process control techniques on measured transfer times of elderly.

    Science.gov (United States)

    Baldewijns, Greet; Luca, Stijn; Nagels, William; Vanrumste, Bart; Croonenborghs, Tom

    2015-01-01

    It has been shown that gait speed and transfer times are good measures of functional ability in elderly. However, data currently acquired by systems that measure either gait speed or transfer times in the homes of elderly people require manual reviewing by healthcare workers. This reviewing process is time-consuming. To alleviate this burden, this paper proposes the use of statistical process control methods to automatically detect both positive and negative changes in transfer times. Three SPC techniques: tabular CUSUM, standardized CUSUM and EWMA, known for their ability to detect small shifts in the data, are evaluated on simulated transfer times. This analysis shows that EWMA is the best-suited method with a detection accuracy of 82% and an average detection time of 9.64 days.

  5. Rise, stagnation, and rise of Danish women's life expectancy

    DEFF Research Database (Denmark)

    Lindahl-Jacobsen, Rune; Rau, Roland; Jeune, Bernard

    2016-01-01

    Health conditions change from year to year, with a general tendency in many countries for improvement. These conditions also change from one birth cohort to another: some generations suffer more adverse events in childhood, smoke more heavily, eat poorer diets, etc., than generations born earlier...... favor forecasts that hinge on cohort differences. We use a combination of age decomposition and exchange of survival probabilities between countries to study the remarkable recent history of female life expectancy in Denmark, a saga of rising, stagnating, and now again rising lifespans. The gap between...... female life expectancy in Denmark vs. Sweden grew to 3.5 y in the period 1975-2000. When we assumed that Danish women born 1915-1945 had the same survival probabilities as Swedish women, the gap remained small and roughly constant. Hence, the lower Danish life expectancy is caused by these cohorts...

  6. Early time implosion symmetry from two-axis shock-timing measurements on indirect drive NIF experiments

    Energy Technology Data Exchange (ETDEWEB)

    Moody, J. D., E-mail: moody4@llnl.gov; Robey, H. F.; Celliers, P. M.; Munro, D. H.; Barker, D. A.; Baker, K. L.; Döppner, T.; Hash, N. L.; Berzak Hopkins, L.; LaFortune, K.; Landen, O. L.; LePape, S.; MacGowan, B. J.; Ralph, J. E.; Ross, J. S.; Widmayer, C. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Nikroo, A.; Giraldez, E. [General Atomics, San Diego, California 92186-5608 (United States); Boehly, T. [Laboratory for Laser Energetics, Rochester, New York 14623-1299 (United States)

    2014-09-15

    An innovative technique has been developed and used to measure the shock propagation speed along two orthogonal axes in an inertial confinement fusion indirect drive implosion target. This development builds on an existing target and diagnostic platform for measuring the shock propagation along a single axis. A 0.4 mm square aluminum mirror is installed in the ablator capsule which adds a second orthogonal view of the x-ray-driven shock speeds. The new technique adds capability for symmetry control along two directions of the shocks launched in the ablator by the laser-generated hohlraum x-ray flux. Laser power adjustments in four different azimuthal cones based on the results of this measurement can reduce time-dependent symmetry swings during the implosion. Analysis of a large data set provides experimental sensitivities of the shock parameters to the overall laser delivery and in some cases shows the effects of laser asymmetries on the pole and equator shock measurements.

  7. Correlation between electrochemical impedance measurements and corrosion rate of magnesium investigated by real-time hydrogen measurement and optical imaging

    OpenAIRE

    Curioni, M.; Scenini, F.; Monetta, T.; Bellucci, F.

    2015-01-01

    The corrosion behaviour of magnesium in chloride-containing aqueous environment was investigated by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) performed simultaneously with real-time hydrogen evolution measurements and optical imaging of the corroding surface. The potentiodynamic investigation revealed substantial deviations from linearity in close proximity of the corrosion potential. In particular, differences in the slope of the current/potential curves w...

  8. Time-resolved measurement of global synchronization in the dust acoustic wave

    Science.gov (United States)

    Williams, J. D.

    2014-10-01

    A spatially and temporally resolved measurement of the synchronization of the naturally occurring dust acoustic wave to an external drive and the relaxation from the driven wave mode back to the naturally occuring wave mode is presented. This measurement provides a time-resolved measurement of the synchronization of the self-excited dust acoustic wave with an external drive and the return to the self-excited mode. It is observed that the wave synchronizes to the external drive in a distinct time-dependent fashion, while there is an immediate loss of synchronization when the external modulation is discontinued.

  9. Effects of light guide and magnetic field on the characteristics of the short time measuring system

    International Nuclear Information System (INIS)

    Yamada, Yoshihiro; Ohira, Kyozo

    1977-01-01

    In order to construct the nuclear life-time measurement apparatus with good energy and time resolution, consisting of DuMond type beta-ray spectrometer and plastic scintillator, experimental studies are carried out for the effects of light guide and magnetic field on the time resolution, and for the effects of μ-metal shielding on the energy resolution. It has been found that all these effects could be practically diminished. (auth.)

  10. Measurement and Prediction of Time-independent and Time-dependent Rheological Behavior of Waxy Crude Oil

    Directory of Open Access Journals (Sweden)

    Yavar Karimi

    2017-01-01

    Full Text Available Wax deposition phenomenon changes the rheological behavior of waxy crude oil completely. In the current work, the rheological time-dependent and time-independent behaviors of waxy crude oil samples are studied and flow curve and compliance function are measured for the oil samples with various wax contents at different temperatures. A decrease in temperature and an increase in wax content lead to an increase in the viscosity and yield stress but a significant drop in compliance function. A modified Burger model is developed to predict the behavior of the compliance function and a modified Casson model is used to predict the flow curve of the waxy crude oil samples within a vast range of wax contents and temperatures. The proposed Burger and Casson models match with experimental results with R2 of 99.7% and 97.33% respectively.

  11. In-situ measurement of response time of RTDs and pressure transmitters in nuclear power plants

    International Nuclear Information System (INIS)

    Hashemian, H.M.; Riner, J.L.

    1993-01-01

    Response time measurements are performed once every fuel cycle on most safety-related temperature and pressure sensors in a majority of nuclear power plants in the US. This paper provides a review of the methods that are used for these measurements. The methods are referred to as the Loop Current Step Response (LCSR) test, which is used for response time testing of temperature sensors, and noise analysis and power interrupt (PI) tests, which are used for response time testing of pressure, level, and flow transmitters

  12. All-optical time-resolved measurement of laser energy modulation in a relativistic electron beam

    Directory of Open Access Journals (Sweden)

    D. Xiang

    2011-11-01

    Full Text Available We propose and demonstrate an all-optical method to measure laser energy modulation in a relativistic electron beam. In this scheme the time-dependent energy modulation generated from the electron-laser interaction in an undulator is converted into time-dependent density modulation with a chicane, which is measured to infer the laser energy modulation. The method, in principle, is capable of simultaneously providing information on femtosecond time scale and 10^{-5} energy scale not accessible with conventional methods. We anticipate that this method may have wide applications in many laser-based advanced beam manipulation techniques.

  13. The Dynamic Method for Time-of-Flight Measurement of Thermal Neutron Spectra from Pulsed Sources

    International Nuclear Information System (INIS)

    Pepelyshev, Yu.N.; Tulaev, A.B.; Bobrakov, V.F.

    1994-01-01

    The time-of-flight method for a measurement of thermal neutron spectra in the pulsed neutron sources with high efficiency of neutron registration, more than 10 5 times higher in comparison with traditional one, is described. The main problems connected with the electric current technique for time-of-flight spectra measurement are examined. The methodical errors, problems of a special neutron detector design and other questions are discussed. Some experimental results, spectra from surfaces of the water and solid methane moderators, obtained in the pulsed reactor IBR-2 (Dubna, Russia) are presented. 4 refs., 5 figs

  14. Measurement of magnetic and electric field inhomogenities in a time projection chamber using laser tracks

    International Nuclear Information System (INIS)

    Benetta, M.; Froberger, J.P.; Lehraus, I.; Mathewson, R.; May, J.; Price, M.; Schlater, D.; Tejessi, W.; Witzeling, W.

    1985-01-01

    The large time projection chambers (TPC) for particle track measurements have their electric drift field parallel to the magnetic field which is needed for the momentum measurement of the particles. Small field inhomogeneities of the order of epsilon times the main field cause large track distortions (coordinate displacements) of the order of epsilon times the driftlength. It is therefore important for every TPC to know the inhomogeneities very well. Laser rays have proven to be useful to study them. We report here on our experience with a TPC having a maximum drift length of 1.3 m

  15. Measurements of cascade times of antiprotons in molecular hydrogen and helium

    CERN Document Server

    Bianconi, A; Corradini, M; Donzella, A; Gómez, G; Lodi-Rizzini, E; Venturelli, L; Vilar, R; Zenoni, A; Bertin, A; Bruschi, M; Capponi, M; De Castro, S; Donà, R; Galli, D; Giacobbe, B; Marconi, U; Massa, I; Piccinini, M; Semprini-Cesari, N; Spighi, R; Vagnoni, V M; Vecchi, S; Villa, M; Vitale, A; Zoccoli, A; Cicalò, C; De Falco, A; Masoni, A; Puddu, G; Serci, S; Usai, G L; Gorchakov, O E; Prakhov, S N; Rozhdestvensky, A M; Tretyak, V I; Poli, M; Gianotti, P; Guaraldo, C; Lanaro, A; Lucherini, V; Petrascu, C; Ableev, V G; Ricci, R A; Vannucci, Luigi; Filippini, V; Fontana, A; Montagna, P; Rotondi, A; Salvini, P; Mirfakhraee, N; Bussa, M P; Busso, L; Cerello, P G; Denisov, O Yu; Ferrero, L; Garfagnini, R; Grasso, A; Maggiora, A; Panzarasa, A; Panzieri, D; Tosello, F; Botta, E; Bressani, Tullio; Calvo, D; Costa, S; D'Isep, F; Feliciello, A; Filippi, A; Marcello, S; Agnello, M; Iazzi, F; Minetti, B; Tessaro, S; Santi, L

    2000-01-01

    The OBELIX experiment at CERN collected samples of antiproton annihilations at rest in different gaseous targets, such as hydrogen, deuterium and helium. We analyze a set of the Obelix data using a new technique for measuring, for the first time, the cascade times independent of the capture energy and of the antiproton stopping power. We report on measurements of the cascade times for hydrogen at 3.4, 5.8, 9.8 and 150 mbar and for helium at 8.2, 50 and 150 mbar pressure. An estimate of the antiproton capture energy in hydrogen is also presented. (12 refs).

  16. Third-order correlator for measuring the time profile of petawatt laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Ginzburg, V N; Lozhkarev, V V; Luchinin, G A; Mironov, S Yu; Khazanov, Efim A; Yakovlev, I V [Institute of Applied Physics, Russian Academy of Sciences, Nizhnii Novgorod (Russian Federation); Didenko, N V; Konyashchenko, Aleksandr V; Lutsenko, Andrei P [' Avesta-project' Ltd., Troitsk, Moscow Region (Russian Federation)

    2008-11-30

    A third-order correlator with a single-shot time window and a full dynamic range of 10{sup 8} is developed. The time contrast of radiation from the front-end system of a petawatt femtosecond laser complex measured with the correlator within time windows {+-}1 ps and {+-}100 ps was 10{sup 4} and more than 10{sup 8}, respectively. Based on the theoretical analysis of the cross-correlator operation, a number of requirements providing the optimal functioning of the cross-correlator are found. The reasons restricting the technical parameters of the correlator are discussed. (measurement of parameters of laser radiation)

  17. The dynamic method for time-of-flight measurement of thermal neutron spectra from pulsed sources

    International Nuclear Information System (INIS)

    Pepyolyshev, Yu.N.; Chuklyaev, S.V.; Tulaev, A.B.; Bobrakov, V.F.

    1995-01-01

    A time-of-flight method for measurement of thermal neutron spectra in pulsed neutron sources with an efficiency more than 10 5 times higher than the standard method is described. The main problems associated with the electric current technique for time-of-flight spectra measurement are examined. The methodical errors, problems of special neutron detector design and other questions are discussed. Some experimental results for spectra from the surfaces of water and solid methane moderators obtained at the IBR-2 pulsed reactor (Dubna, Russia) are presented. (orig.)

  18. Third-order correlator for measuring the time profile of petawatt laser pulses

    International Nuclear Information System (INIS)

    Ginzburg, V N; Lozhkarev, V V; Luchinin, G A; Mironov, S Yu; Khazanov, Efim A; Yakovlev, I V; Didenko, N V; Konyashchenko, Aleksandr V; Lutsenko, Andrei P

    2008-01-01

    A third-order correlator with a single-shot time window and a full dynamic range of 10 8 is developed. The time contrast of radiation from the front-end system of a petawatt femtosecond laser complex measured with the correlator within time windows ±1 ps and ±100 ps was 10 4 and more than 10 8 , respectively. Based on the theoretical analysis of the cross-correlator operation, a number of requirements providing the optimal functioning of the cross-correlator are found. The reasons restricting the technical parameters of the correlator are discussed. (measurement of parameters of laser radiation)

  19. Simplified method for measuring the response time of scram release electromagnet in a nuclear reactor

    Energy Technology Data Exchange (ETDEWEB)

    Patri, Sudheer, E-mail: patri@igcar.gov.in; Mohana, M.; Kameswari, K.; Kumar, S. Suresh; Narmadha, S.; Vijayshree, R.; Meikandamurthy, C.; Venkatesan, A.; Palanisami, K.; Murthy, D. Thirugnana; Babu, B.; Prakash, V.; Rajan, K.K.

    2015-04-15

    Highlights: • An alternative method for estimating the electromagnet clutch release time. • A systematic approach to develop a computer based measuring system. • Prototype tests on the measurement system. • Accuracy of the method is ±6% and repeatability error is within 2%. - Abstract: The delay time in electromagnet clutch release during a reactor trip (scram action) is an important safety parameter, having a bearing on the plant safety during various design basis events. Generally, it is measured using current decay characteristics of electromagnet coil and its energising circuit. A simplified method of measuring the same in a Sodium cooled fast reactors (SFR) is proposed in this paper. The method utilises the position data of control rod to estimate the delay time in electromagnet clutch release. A computer based real time measurement system for measuring the electromagnet clutch delay time is developed and qualified for retrofitting in prototype fast breeder reactor. Various stages involved in the development of the system are principle demonstration, experimental verification of hardware capabilities and prototype system testing. Tests on prototype system have demonstrated the satisfactory performance of the system with intended accuracy and repeatability.

  20. An improved measurement system for FOG pure lag time with no changing of FOG work status

    Science.gov (United States)

    Chen, X.; Yang, J. H.; Zhou, Y. L.; Shu, X. W.

    2018-05-01

    The minimum pure lag time is an important factor for characterizing the dynamic performance of fiber optical gyroscope. It is defined as the time duration from the reception of velocity-shock signal to the output of corresponding fiber-optic gyroscope data. Many engineering projects have required for this index specifically, so the measurement of the minimum pure lag time is highly demanded. In typically measurement system, the work status of tested FOG has to be changed. In this work, a FOG pure lag time measurement system without changing the work status of the FOG has been demonstrated. During the operation of this test system, the impact structure generated a shock towards the FOG, and the pure lag time was measured through data processing analysis. The design scheme and test principle have been researched and analyzed in detail. And a prototype has been developed and used for experiment successfully. This measurement system can realize a measurement accuracy of better than ±3 μs and a system resolution of 108.6ns.