WorldWideScience

Sample records for ring opening angles

  1. Glaucoma, Open-Angle

    Science.gov (United States)

    ... Home » Statistics and Data » Glaucoma, Open-angle Listen Glaucoma, Open-angle Open-angle Glaucoma Defined In open-angle glaucoma, the fluid passes ... 2010 2010 U.S. Age-Specific Prevalence Rates for Glaucoma by Age and Race/Ethnicity The prevalence of ...

  2. Ring magnet firing angle control

    International Nuclear Information System (INIS)

    Knott, M.J.; Lewis, L.G.; Rabe, H.H.

    1975-01-01

    A device is provided for controlling the firing angles of thyratrons (rectifiers) in a ring magnet power supply. A phase lock loop develops a smooth ac signal of frequency equal to and in phase with the frequency of the voltage wave developed by the main generator of the power supply. A counter that counts from zero to a particular number each cycle of the main generator voltage wave is synchronized with the smooth AC signal of the phase lock loop. Gates compare the number in the counter with predetermined desired firing angles for each thyratron and with coincidence the proper thyratron is fired at the predetermined firing angle

  3. Nucleophilic ring opening reactions of aziridines.

    Science.gov (United States)

    Akhtar, Rabia; Naqvi, Syed Ali Raza; Zahoor, Ameer Fawad; Saleem, Sameera

    2018-05-04

    Aziridine ring opening reactions have gained tremendous importance in the synthesis of nitrogen containing biologically active molecules. During recent years, a great effort has been put forward by scientists toward unique bond construction methodologies via ring opening of aziridines. In this regard, a wide range of chiral metal- and organo-catalyzed desymmetrization reactions of aziridines have been reported with carbon, sulfur, oxygen, nitrogen, halogen, and other nucleophiles. In this review, an outline of methodologies adopted by a number of scientists during 2013-2017 for aziridine ring opening reactions as well as their synthetic applications is described.

  4. Open-ring enhancement sign in diagnosing demyelinating pseudotumor

    International Nuclear Information System (INIS)

    Fang Liting; Wang Zhiping; Wang Linyou

    2010-01-01

    Objective: To describe open-ring enhancement sign on MRI of demyelinating pseudotumor. Methods: Contrast-enhanced MRI of histologically confirmed demyelinating pseudotumors (14 patients) and astrocytomas (21) was reviewed. Results: Of the 14 cases of demyelinating pseudotumor, open-ring enhancement pattern was observed in 6; closed ring enhancement in 2; nodular enhancement in 3; patchy enhancement in 1; slight enhancement in 1; and no enhancement in 1. Of the 21 cases of astrocytoma, there was complete ring or lace-like enhancement in 13, no contrast enhancement in 6, patchy enhancement in 2, and none with open-ring enhancement pattern. Conclusion: Open-ring enhancement is a valuable sign in differential diagnosis between demyelinating pseudotumor and astrocytoma. (authors)

  5. Plasma-ring, fast-opening switch

    International Nuclear Information System (INIS)

    Hartman, C.W.; Eddleman, J.; Hammer, J.H.

    1986-01-01

    The authors discuss a fast-opening switch concept based on magnetically confined plasma rings, PROS (for Plasma Ring Opening Switch). In PROS, the plasma ring, confined by Bθ /sub and B/poloidal /sub fields of a compact torus, provide a low mass, localized conduction path between coaxial electrodes. To operate the switch, driver current is passed across the electrodes through the ring, storing inductive energy in external inductance and between the electrodes on the driver side of the ring. The ring is accelerated away from the driver by the field of the driver current and passes over a load gap transferring the current to the load. The authors distinguish two configurations in PROS, straight PROS where the electrodes are coaxial cylinders, and cone PROS with conical electrodes. In straight PROS ring acceleration takes place during the inductive store period as in foil switches, but with the localized ring providing the current path. Increased performance is predicted for the cone PROS (see figure) which employs compression of the ring in the cone during the inductive store period. Here, the B/θ /sub field of the driver forces the ring towards the apex of the cone but the force is in near balance with the opposing component of the radial equilibrium force of the ring along the cone. As a result, the ring undergoes a slow, quasistatic compression limited only by resistive decay of the ring field. Slow compression allows inductive storage with low-power drivers (homopoloar, magneto cumulative generators, high C-low V capacitor banks, etc.). Near the apex of the cone, near peak compression, the ring is allowed to enter a straight coaxial section where, because of low-mass, it rapidly accelerates to high velocity and crosses the load gap

  6. Ring opening of epoxides with C-nucleophiles.

    Science.gov (United States)

    Faiz, Sadia; Zahoor, Ameer Fawad

    2016-11-01

    Ring opening of epoxides has been an area of interest for organic chemists, owing to their reactivity toward nucleophiles. Such reactions yield important products depending on the type of nucleophiles used. This review article covers the synthetic approaches (1991-2015) used for the ring opening of epoxides via carbon nucleophiles.

  7. Goniodysgenesis in familial primary open-angle glaucoma

    NARCIS (Netherlands)

    Verbraak, F. D.; vd Berg, W.; Delleman, J. W.; Greve, E. L.

    1994-01-01

    Results of a pilot study to evaluate goniodysgenesis as a cause of familial open-angle glaucoma are reported. Patients with a familial high tension open-angle glaucoma and a goniodysgenetic chamber angle (n = 11), a number of their relatives with glaucoma (n = 12), and their relatives without

  8. Photosonochemical catalytic ring opening of α-epoxyketones

    Directory of Open Access Journals (Sweden)

    Saffar-Teluri Ali

    2007-01-01

    Full Text Available Abstract The combination of ultrasound and photochemical methods has been used for the catalytic ring opening of α-epoxyketones by 1-benzyl-2,4,6-triphenylpyridinium tetrafluoroborate (NBTPT as photocatalyst in methanol. Sonication of these compounds in the presence of NBTPT did not result in the opening of epoxide ring, but the use of ultrasound increased the rate of photoreaction.

  9. Numerical study of pressure fluctuations in different guide vanes' opening angle in pump mode of a pump turbine

    International Nuclear Information System (INIS)

    Sun, Y K; Zuo, Z G; Liu, S H; Wu, Y L; Liu, J T

    2012-01-01

    A numerical model based on a pumped storage power station was built to develop the numerical simulation, to analyze the pressure fluctuations in a pump turbine in different guide vanes' opening angle. The different guide vanes' opening angles were simulated using the SST k-ω turbulence model and SIMPLEC Pressure-Velocity coupling scheme. The pressure sensor were placed in mainly three positions, they are: bottom ring between runner and the wicket gates, downstream and left side in the draft tube cone below the runner. All the peak to peak values of pressure fluctuation meet signal probability of 97%. The frequency is gained by Fast Fourier Transform. The pressure fluctuations in different positions of the model in pump condition were showed when the guide vanes' opening angels were different. The simulation results confirmed the results gained in model tests. The results show that pressure fluctuations in design opening angle were much lower than those in off design opening angle. The main source of pressure fluctuations between runner and guide vanes is rotor stator interaction. While a lower frequency is the main frequency of the pressure fluctuation in draft tube.

  10. Ring-opening of gamma-valerolactone with amino compounds

    NARCIS (Netherlands)

    Chalid, Mochamad; Heeres, Hero J.; Broekhuis, Antonius A.

    2012-01-01

    Diols obtained by the ring-opening of biomass-based gamma-valerolactone (GVL) are potentially valuable building blocks that can be used as precursors in the manufacture of green polymers and resins. We report here a study on the ring-opening of GVL through adding amine compounds. The reactivity of

  11. Undetected angle closure in patients with a diagnosis of open-angle glaucoma.

    Science.gov (United States)

    Varma, Devesh K; Simpson, Sarah M; Rai, Amandeep S; Ahmed, Iqbal Ike K

    2017-08-01

    The aim of this study was to identify the proportion of patients referred to a tertiary glaucoma centre with a diagnosis of open-angle glaucoma (OAG) who were found to have angle closure glaucoma. Retrospective chart review. Consecutive new patients referred for glaucoma management to a tertiary centre between July 2010 and December 2011 were reviewed. Patients whose referrals for glaucoma assessment specified angle status as "open" were included. The data collected included glaucoma specialist's angle assessment, diagnosis, and glaucoma severity. The status of those with 180 degrees or more Shaffer angle grading of 0 was classified as "closed." From 1234 glaucoma referrals, 179 cases were specified to have a diagnosis of OAG or when angles were known to be open. Of these, 16 (8.9%) were found on examination by the glaucoma specialist to have angle closure. Pseudoexfoliation was present in 4 of 16 patients (25%) in the missed angle-closure glaucoma (ACG) group and 22 of 108 patients (13.5%) in the remaining OAG group. There was no difference found in demographic or ocular biometric parameters between those with confirmed OAG versus those with missed ACG. Almost 1 in 11 patients referred by ophthalmologists to a tertiary glaucoma centre with a diagnosis of OAG were in fact found to have angle closure. Given the different treatment approaches for ACG versus OAG, this study suggests a need to strengthen angle evaluations. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  12. Development of a single-ring OpenPET prototype

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Eiji, E-mail: rush@nirs.go.jp; Tashima, Hideaki; Wakizaka, Hidekatsu; Nishikido, Fumihiko; Hirano, Yoshiyuki; Inadama, Naoko; Murayama, Hideo; Ito, Hiroshi; Yamaya, Taiga

    2013-11-21

    One of the challenging applications of PET is implementing it for in-beam PET, which is an in situ monitoring method for charged particle therapy. For this purpose, we have previously proposed an open-type PET scanner, OpenPET. The original OpenPET had a physically opened field-of-view (FOV) between two detector rings through which irradiation beams pass. This dual-ring OpenPET (DROP) had a wide axial FOV including the gap. This geometry was not necessarily the most efficient for application to in-beam PET in which only a limited FOV around the irradiation field is required. Therefore, we have proposed a new single-ring OpenPET (SROP) geometry which can provide an accessible and observable open space with higher sensitivity and a reduced number of detectors than the DROP. The proposed geometry was a cylinder shape with its ends cut at a slant, in which the shape of each cut end became an ellipse. In this work, we developed and evaluated a small prototype of the SROP geometry for proof-of-concept. The SROP prototype was designed with 2 ellipse-shaped detector rings of 16 depth-of-interaction (DOI) detectors each. The DOI detectors consisted of 1024 GSOZ scintillator crystals which were arranged in 4 layers of 16×16 arrays, coupled to a 64-channel FP-PMT. Each ellipse-shaped detector ring had a major axis of 281.6 mm and a minor axis of 207.5 mm. For the slant mode, the rings were placed at a 45-deg slant from the axial direction and for the non-slant mode (used as a reference) they were at 90 deg from the axial direction with no gap. The system sensitivity measured from a {sup 22}Na point source was 5.0% for the slant mode. The average spatial resolutions of major and minor axis directions were calculated as 3.8 mm FWHM and 4.9 mm FWHM, respectively for the slant mode. This difference resulted from the ellipsoidal ring geometry and the spatial resolution of the minor axis direction degraded by the parallax error. Comparison between the slant mode and the non

  13. Monte Carlo simulation of second-generation open-type PET ''single-ring OpenPET'' implemented with DOI detectors

    International Nuclear Information System (INIS)

    Tashima, Hideaki; Yamaya, Taiga; Hirano, Yoshiyuki; Yoshida, Eiji; Kinouch, Shoko; Watanabe, Mitsuo; Tanaka, Eiichi

    2013-01-01

    At the National Institute of Radiological Sciences, we are developing OpenPET, an open-type positron emission tomography (PET) geometry with a physically open space, which allows easy access to the patient during PET studies. Our first-generation OpenPET system, dual-ring OpenPET, which consisted of two detector rings, could provide an extended axial field of view (FOV) including the open space. However, for applications such as in-beam PET to monitor the dose distribution in situ during particle therapy, higher sensitivity concentrated on the irradiation field is required rather than a wide FOV. In this report, we propose a second-generation OpenPET geometry, single-ring OpenPET, which can efficiently improve sensitivity while providing the required open space. When the proposed geometry was realized with block detectors, position-dependent degradation of the spatial resolution was expected because it was necessary to arrange the detector blocks in ellipsoidal rings stacked and shifted relative to one another. However, we found by Monte Carlo simulation that the use of depth-of-interaction (DOI) detectors made it feasible to achieve uniform spatial resolution in the FOV. (author)

  14. Relationship between retinal lattice degeneration and open angle glaucoma.

    Science.gov (United States)

    Rahimi, Mansour

    2005-01-01

    Patients with retinal disorders may develop glaucoma of both a primary and secondary type. Pigment may contribute to trabecular obstruction in some patients with open-angle glaucoma. Lattice degeneration of the retina in its typical form is a sharply demarcated, circumferentially oriented, degenerative process with significant alterations of retinal pigmentation. The association between myopia, open angle glaucoma and pigment dispersion is striking. Therefore, it could be postulated that there is significant prevalence of open angle glaucoma in patients with retinal lattice degeneration, especially in combination with myopia.

  15. Lamina cribrosa position and Bruch's membrane opening differences between anterior ischemic optic neuropathy and open-angle glaucoma.

    Science.gov (United States)

    Rebolleda, Gema; Pérez-Sarriegui, Ane; Díez-Álvarez, Laura; De Juan, Victoria; Muñoz-Negrete, Francisco J

    2018-06-01

    To compare the optic nerve head morphology among primary open-angle glaucoma, non-arteritic anterior ischemic optic neuropathy eyes, their fellow healthy eyes and control eyes, using spectral-domain optical coherence tomography with enhanced depth imaging. Observational cross-sectional study including 88 eyes of 68 patients. In this study, 23 non-arteritic anterior ischemic optic neuropathy eyes, 17 fellow unaffected eyes, 25 primary open-angle glaucoma eyes, and 23 age-matched control eyes were included. Peripapillary retinal nerve fiber layer thickness and optic disk area were evaluated. Bruch's membrane opening diameter, optic cup depth, anterior lamina cribrosa depth, and prelaminar tissue thickness were assessed. Non-arteritic anterior ischemic optic neuropathy and primary open-angle glaucoma eyes had similar visual field mean deviation and peripapillary retinal nerve fiber layer thickness (P = 0.6 and P = 0.56, respectively). Bruch's membrane opening diameter was significantly larger in primary open-angle glaucoma eyes than in control eyes (P = 0.02). Lamina cribrosa and disk cup were deeper in eyes with primary open-angle glaucoma than both control and non-arteritic anterior ischemic optic neuropathy eyes (P open-angle glaucoma eyes than in non-arteritic anterior ischemic optic neuropathy eyes (P opening diameter was found in primary open-angle glaucoma eyes compared with control eyes. This issue has clinical implications because Bruch's membrane opening has been considered a stable reference for disk-related measures.

  16. Piranti Lunak Pengujian Struktur Matematika Grup, Ring, Field Berbasis Osp (Open Source Program

    Directory of Open Access Journals (Sweden)

    Ngarap Im Manik

    2014-06-01

    Full Text Available This design of a computer software is a development and continuation of the software made on the previous research (2009/2010. However, this further research developed and expanded the scopes of testing more on the Siclic Group, Isomorphism Group, Semi Group, Sub Group and Abelian Group, Factor Ring, Sub Ring and Polynomial Ring; developed on the OSP (Open Source Program-based. The software was developed using the OSP-based language programming, such Java, so it is open and free to use for its users. This research succeeded to develop an open source software of Java program that can be used for testing specific mathematical Groups, such Ciclic Group, Isomorphism Group, Semi Group, Sub Group and Abelian Group, and Rings, Commutative Ring, Division Ring, Ideal Sub Ring, Ring Homomorphism, Ring Epimorphism and Fields. By the results, the software developed was able to test as same as the results from manual testing.

  17. Presentation of Primary Open Angle Glaucoma (POAG) at Lions ...

    African Journals Online (AJOL)

    Objective Primary open angle glaucoma (POAG) is the most common type of glaucoma in Africa. We carried out a study to determine the clinical presentation pattern of patients with primary open angle glaucoma (POAG) at a tertiary hospital in Malawi. Design A cross-sectional study. Setting Lions Sight First Eye Hospital—a ...

  18. Structure and magnetic field of periodic permanent magnetic focusing system with open magnetic rings

    International Nuclear Information System (INIS)

    Peng Long; Li Lezhong; Yang Dingyu; Zhu Xinghua; Li Yuanxun

    2011-01-01

    The magnetic field along the central axis for an axially magnetized permanent magnetic ring was investigated by analytical and finite element methods. For open magnetic rings, both calculated and measured results show that the existence of the radial magnetic field creates a remarkable cosine distribution field along the central axis. A new structure of periodic permanent magnet focusing system with open magnetic rings is proposed. The structure provides a satisfactory magnetic field with a stable peak value of 120 mT for a traveling wave tube system. - Research highlights: → For open magnetic rings, both calculated and measured results show that the existence of the radial magnetic field creates a remarkable cosine distribution field along the central axis. → A new structure of periodic permanent magnet (PPM) focusing system with open magnetic rings is proposed. → The new PPM focusing system with open magnetic rings meets the requirements for TWT system.

  19. Conductance of closed and open long Aharonov-Bohm-Kondo rings

    Science.gov (United States)

    Shi, Zheng; Komijani, Yashar

    2017-02-01

    We calculate the finite temperature linear dc conductance of a generic single-impurity Anderson model containing an arbitrary number of Fermi liquid leads, and apply the formalism to closed and open long Aharonov-Bohm-Kondo (ABK) rings. We show that, as with the short ABK ring, there is a contribution to the conductance from the connected four-point Green's function of the conduction electrons. At sufficiently low temperatures this contribution can be eliminated, and the conductance can be expressed as a linear function of the T matrix of the screening channel. For closed rings we show that at temperatures high compared to the Kondo temperature, the conductance behaves differently for temperatures above and below vF/L , where vF is the Fermi velocity and L is the circumference of the ring. For open rings, when the ring arms have both a small transmission and a small reflection, we show from the microscopic model that the ring behaves like a two-path interferometer, and that the Kondo temperature is unaffected by details of the ring. Our findings confirm that ABK rings are potentially useful in the detection of the size of the Kondo screening cloud, the π /2 scattering phase shift from the Kondo singlet, and the suppression of Aharonov-Bohm oscillations due to inelastic scattering.

  20. Primary Open-Angle Glaucoma and Serum Lipids

    Directory of Open Access Journals (Sweden)

    Suzana Pavljašević

    2009-02-01

    Full Text Available The aim of this paper was to prove the relation between serum lipid values (cholesterol, trig- lyceride, low density cholesterol, high density cholesterol and primary open -angle glaucoma. The study includes two patient groups: 50 patients with primary open-angle glaucoma and 50 patients without this disease. However, all 100 patients were tested for serum lipid values. The research covered a period of six months (from May to December 2007.. Primary open-angle glaucoma was diagnosed with intraocular pressure values (between 20,1 and 25,6 mm Hg measured with Schiotz tonometry. The visual field changes were confirmed with Goldmann perimetry. The gonioscopies were done for diagnosis confirmation. The serum lipid values were confirmed with enzymatic colorimetry in vitro method. U-test (Mann-Witney-Wilcox test and t-test, as nonparametric tests, were used for statistical evaluations. The cholesterol mean value in the test group was 6,14 mol/dm1 (3,20-8,10 mol/dm3 whereas in the control group it was 5,96 mol/dm3 (2,70-8,80 mol/dm3. U-test was with negative ranks (z=-0,83 AS=0,678. The triglyceride mean value in the test group was 2,38 mol/dm3 (0,84-11,73 mol/m3 and in the control group it was 2,04 mol/dm3 (0,63-5,89 mol/dm3. U-test was with positive ranks (z=0,950 AS=0,342. High density cholesterol was average in the test group with 1,45 mol/dm3 (0,71-3,40 mol/dm3 and in the control group 1,40 mol/m3 (0,80-3,20 mol/dm3. Low density cholesterol in the test group was 3,98 mol/m3 (1,82-6,49 mol/m3 and in the control group 4,08 mol/m3 (2,69-5,69 mol/m3. These results had positive ranks according to U-test. Serum lipid values could be one of predictable factors in primary open-angle glaucoma diagnosis. Due to the patient age, cholesterol values, as common factors in primary open-angle glaucoma and atherosclerosis genesis, could be concern in the same aetiology based on dyslipidaemia as well.

  1. Common pass decentered annular ring resonator

    Energy Technology Data Exchange (ETDEWEB)

    Holmes, D. A.; Waite, T. R.

    1985-04-30

    An optical resonator having an annular cylindrical gain region for use in a chemical laser or the like in which two ring-shaped mirrors having substantially conical reflecting surfaces are spaced apart along a common axis of revolution of the respective conical surfaces. A central conical mirror reflects incident light directed along said axis radially outwardly to the reflecting surface of a first one of the ring-shaped mirrors. The radial light rays are reflected by the first ring mirror to the second ring mirror within an annular cylindrical volume concentric with said common axis and forming a gain region. Light rays impinging on the second ring mirror are reflected to diametrically opposite points on the same conical mirror surfaces and back to the first ring mirror through the same annular cylindrical volume. The return rays are then reflected by the conical mirror surface of the first ring mirror back to the central conical mirror. The mirror surfaces are angled such that the return rays are reflected back along the common axis by the central mirror in a concentric annular cylindrical volume. A scraper mirror having a central opening centered on said axis and an offset opening reflects all but the rays passing through the two openings in an output beam. The rays passing through the second opening are reflected back through the first opening to provide feedback.

  2. Efficient, regioselective ring-opening of activated aziridine-2-carboxylates with [18F]fluoride

    DEFF Research Database (Denmark)

    Schjøth-Eskesen, Christina; Hansen, Paul Robert; Kjær, Andreas

    2015-01-01

    Aziridines can undergo a range of ring-opening reactions with nucleophiles. The regio- and stereochemistry of the products depend on the substituents on the aziridine. Aziridine ring-opening reactions have rarely been used in radiosynthesis. Herein we report the ring opening of activated aziridine...

  3. Research advances on multifocal electroretinogram in primary open angle glaucoma

    Directory of Open Access Journals (Sweden)

    Feng-Fei Mo

    2013-10-01

    Full Text Available Primary open angle glaucoma is a chronic and progressive optic neuropathy. It can lead to serious damage of visual impairment, and it is an important eye disease of blindness. Multifocal electroretinogram is a new way to measure visual electrophysiology. It can measure electroretinogram of the whole visual field of many small parts in a relatively short period of time, and it can reflect the function of regional retina. It has an extremely important value for early diagnosis of primary open angle glaucoma. The research advances on multifocal electroretinogram in diagnosing primary open angle glaucoma were summarized in this paper.

  4. Early diagnosis and research of high myopia with primary open angle glaucoma

    Directory of Open Access Journals (Sweden)

    Yan Guo

    2014-04-01

    Full Text Available People with high myopia are high risk populations to have primary open angle glaucoma. Clinically, we found that patients with primary open angle glaucoma and high myopia is closely related. So to understand the clinical features of high myopia with primary open angle glaucoma and the importance of early diagnosis, to avoiding missed diagnosis or lower misdiagnosed rate, can help to improve the vigilance and level of early diagnosis of the clinicians. In this paper, high myopia with clinical features of primary open angle glaucoma, and the research progress on the main points of early diagnosis were reviewed.

  5. Catalytic ring opening of cyclic hydrocarbons in diesel fuels

    Energy Technology Data Exchange (ETDEWEB)

    Calemma, V.; Ferrari, M. [Eni S.p.A., San Donato Milanese (Italy). R and M Div.; Rabl, S.; Haas, A.; Santi, D.; Weitkamp, J. [Stuttgart Univ. (Germany). Inst. of Chemical Technology

    2013-11-01

    An approach for high-aromatic streams upgrading, allowing to meet future diesel quality standards, is saturation of the aromatic structures followed by the selective breaking of endocyclic C-C bonds of naphthenic structures so formed to produce alkanes with the same number of carbon atoms as the starting molecule ('selective ring opening, SRO'). Although theoretically, SRO is a promising route for upgrading low-value feeds to high-quality products, in practice, it continues to be a challenge owing to its complex chemistry. Product characteristics, do not only depend on the composition of the feed, but also on the operating conditions and the nature of the catalyst. Very recently, novel catalysts ('HIgh-PErformance Ring Opening Catalysts, HIPEROCs') were developed which allow a very selective ring opening of the model compound decalin to paraffins without degradation of the carbon number. The hydroconversion of dearomatized Light Cycle Oil (DeAr-LCO) over the abovementioned catalysts resulted in a remarkable change of the chemical structure of the feed with a strong decrease of naphthenic structures with two or more condensed rings and a concomitant increase of alkyl-substituted cyclohexanes and open-chain alkanes. The changes occurring in the chemical structures of feedstock during hydroconversion resulted in a remarkable increase of the Cetane Index of the products up to 11 units. In the present contribution, we examine the main factors affecting activity and selectivity of SRO catalysts in the light of the recent literature dealing with the subject and we report on the recent advances in hydroconversion of refinery cuts such as DeAr- LCO over HIPEROCs. (orig.)

  6. Novel Platinum-Catalyzed Ring-Opening of 1,2-Cyclopropanated Sugars with Alcohols

    DEFF Research Database (Denmark)

    Beyer, Jürgen; Madsen, Robert

    1998-01-01

    Reaction of 1,2-cyclopropanated sugars with a catalytic amount ofZeise's dimer [Pt(C2H4)Cl2]2 and an alcohol gives 2-C-branched glycosides by a novel platinum catalyzed ring-opening. A wide variety of alcohols can participate in this ring-opening reaction giving 2-C-branched glycosides ranging from...

  7. {open_quotes}O{close_quotes} ring sealed process tube, Phase II, test project

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R.E.

    1951-04-09

    The {open_quotes}O{close_quotes} ring seal has been proposed to replace the van stone flange and the bellows thermal expansion assembly currently used on the existing Hanford piles to achieve water and gas seals, respectively. Possible advantages of the {open_quotes}O{close_quotes} ring seal are: (1) simplification of component parts and elimination of van stone corrosion; (2) simplification of maintenance; (3) lower costs of initial erection; (4) increased strength. This test supplements Test Project No. 27 (a preliminary thermal cycling test) in applying the {open_quotes}O{close_quotes} ring seal assembly to actual pile operating conditions.

  8. Current density waves in open mesoscopic rings driven by time-periodic magnetic fluxes

    International Nuclear Information System (INIS)

    Yan Conghua; Wei Lianfu

    2010-01-01

    Quantum coherent transport through open mesoscopic Aharonov-Bohm rings (driven by static fluxes) have been studied extensively. Here, by using quantum waveguide theory and the Floquet theorem we investigate the quantum transport of electrons along an open mesoscopic ring threaded by a time-periodic magnetic flux. We predicate that current density waves could be excited along such an open ring. As a consequence, a net current could be generated along the lead with only one reservoir, if the lead additionally connects to such a normal-metal loop driven by the time-dependent flux. These phenomena could be explained by photon-assisted processes, due to the interaction between the transported electrons and the applied oscillating external fields. We also discuss how the time-average currents (along the ring and the lead) depend on the amplitude and frequency of the applied oscillating fluxes.

  9. Platinum Catalyzed Ring-Opening of 1,2-Cyclopropanated Sugars with O-Nucleophiles

    DEFF Research Database (Denmark)

    Beyer, Jürgen; Skaanderup, Philip Robert; Madsen, Robert

    1999-01-01

    In the presence of a catalytic amount of Zeise's dimer 1,2-cyclopropanated sugars undergo regioselective ring-opening at C-1 with O-nucleophiles including alcohols, phenols and water to produce 2-C-branched carbohydrates.......In the presence of a catalytic amount of Zeise's dimer 1,2-cyclopropanated sugars undergo regioselective ring-opening at C-1 with O-nucleophiles including alcohols, phenols and water to produce 2-C-branched carbohydrates....

  10. Trabectome surgery for primary and secondary open angle glaucomas.

    Science.gov (United States)

    Jordan, Jens F; Wecker, Thomas; van Oterendorp, Christian; Anton, Alexandra; Reinhard, Thomas; Boehringer, Daniel; Neuburger, Matthias

    2013-12-01

    In most forms of open angle glaucoma, the trabecular meshwork is the main barrier for aqueous humor outflow, causing elevated intraocular pressure (IOP). The Trabectome is a minimal invasive device for the surgical treatment of open angle glaucoma, particularly eliminating the juxtacanalicular meshwork. This study was conducted to compare the effectiveness and complication profile among different glaucoma subgroups. Single center prospective observational study. There were 557 consecutive eyes of 487 patients included in this study. Trabectome surgery was performed either alone or in combination with cataract surgery. Intraoperative and postoperative complications were documented systematically. Main outcome measures were IOP reduction over time and the preoperative and postoperative number of IOP-lowering medications. Due to subgroup sizes, only data from eyes with primary open angle glaucoma and pseudoexfoliation glaucoma were processed for statistical analysis. For the 261 eyes classified as primary open angle glaucoma, preoperative IOP was 24 ± 5.5 mmHg (mean ± SD) under 2.1 ± 1.3 IOP-lowering medications. After a mean follow-up of 204 ± 238 days, IOP was reduced to 18 ± 6.1 mmHg, and medication was reduced to 1.2 ± 1.1. For the 173 eyes classified as pseudoexfoliation glaucoma, after a mean follow-up of 200 ± 278 days, IOP was reduced from 25 ± 5.9 mmHg to 18 ± 8.2 mmHg, and medication was reduced from 2.0 ± 1.2 to 1.1 ± 1.1. A Cox proportional hazards model hinted forward superiority of the combined surgery cases (Trabectome + Phaco + intraocular lens) in comparison to Trabectome surgery only in phakic or pseudophakic eyes. No serious complications were observed. Minimal invasive glaucoma surgery with the Trabectome seems to be safe and effective. The subgroup analysis of different kinds of open angle glaucomas presented in this study may help in first-line patient selection. The lack of ocular surface alterations makes it a valuable addition to

  11. ESTIMATING LONG GRB JET OPENING ANGLES AND REST-FRAME ENERGETICS

    Energy Technology Data Exchange (ETDEWEB)

    Goldstein, Adam [Space Science Office, VP62, NASA/Marshall Space Flight Center, Huntsville, AL 35812 (United States); Connaughton, Valerie [Science and Technology Institute, Universities Space Research Association, Huntsville, AL 35805 (United States); Briggs, Michael S.; Burns, Eric, E-mail: adam.m.goldstein@nasa.gov [Center for Space Plasma and Aeronomic Research, University of Alabama in Huntsville, 320 Sparkman Drive, Huntsville, AL 35899 (United States)

    2016-02-10

    We present a method to estimate the jet opening angles of long duration gamma-ray bursts (GRBs) using the prompt gamma-ray energetics and an inversion of the Ghirlanda relation, which is a correlation between the time-integrated peak energy of the GRB prompt spectrum and the collimation-corrected energy in gamma-rays. The derived jet opening angles using this method and detailed assumptions match well with the corresponding inferred jet opening angles obtained when a break in the afterglow is observed. Furthermore, using a model of the predicted long GRB redshift probability distribution observable by the Fermi Gamma-ray Burst Monitor (GBM), we estimate the probability distributions for the jet opening angle and rest-frame energetics for a large sample of GBM GRBs for which the redshifts have not been observed. Previous studies have only used a handful of GRBs to estimate these properties due to the paucity of observed afterglow jet breaks, spectroscopic redshifts, and comprehensive prompt gamma-ray observations, and we potentially expand the number of GRBs that can be used in this analysis by more than an order of magnitude. In this analysis, we also present an inferred distribution of jet breaks which indicates that a large fraction of jet breaks are not observable with current instrumentation and observing strategies. We present simple parameterizations for the jet angle, energetics, and jet break distributions so that they may be used in future studies.

  12. New transition metal complexes and their ring-opened polymers

    Science.gov (United States)

    Apodaca, Paula

    An exciting new class of metallacycle (eta5-C5 H4Fe) (CO)2CH2SiR2 that undergoes ring-opening polymerization was recently reported by Sharma et al. [1]. We are interested in further expanding this research area by synthesizing related cyclopentadienyl derivatives containing Fe, Mo, and W in combination with other elements of the group 14. We report here the synthesis and crystal structure characterization of new germa-metallacyclobutanes of Mo and W. In addition, we have successfully synthesized and characterized new ring-opening polymers of the related germanium systems [(eta5-C5 H4Fe)(CO) 2(CH2GeR2)] n. The new polymers were characterized using various spectroscopic techniques and gel permeation chromatography. The recent report on the synthesis of a new class of siloxane polymers based upon base-catalyzed ring opening of phenylene-bridged cyclic siloxanes [2] encouraged us to investigate the related ferrocenyl (Fc, (C5H 5)Fe(C5H4)) siloxane systems. The incorporation of ferrocene could provide new materials with all the interesting properties usually associated with these groups such as thermal and photochemical stability, electrochemical activity and potentially conducting materials. Thus far a new required organometallic monomer containing Fc-R, where R = disilaoxacyclopentene 5 has been synthesized and completely characterized. Based-induced ring-opening polymerizations of 5 were attempted under different reaction conditions and produced, inter alia: (C5H5)Fe(C 5H4)C(SiMe2OH)=CH(SiMe2R), R = nBu (2), tBu (3), Ph (4). The single crystal X-ray structures and full spectroscopic analysis of such products has been accomplished. Furthermore, the reactivity of the ferrocenyl silanols concerning condensation and their behavior under acidic conditions has been investigated. 1Sharma, H.; Cervantes-Lee, F.; Pannell, K. H. J. Am. Chem. Soc. 2004, 126, 1326. 2 Loy, A. D.; Rahimian, K.; Samara, M. Angew. Chem. 1999, 38, 45.

  13. Synthesis of Human Milk Oligosaccharides and Regioselective Ring Opening of Oxabicycles

    DEFF Research Database (Denmark)

    Jennum, Camilla Arboe

    . The tetrasaccharides were formed both by sequential and the developed one-pot method. Deprotection of the protecting group at the C-2-position on the galactose moiety liberated an acceptor for the fucosylation eventually creating the two linear pentasaccharides Lacto-N-fucopentaose I and Lacto-N-neofucopentaose I...... ligands. The ring opened iii products were similar to compounds, which had shown to be potential protein Bcl-XL antagonists, a target for future drugs in cancer treatment. The aim was to create a general asymmetric ring opening method of several enantiopure oxabicycles having different functional moieties...

  14. Preparation of Bottlebrush Polymers via a One-Pot Ring-Opening Polymerization (ROP) and Ring-Opening Metathesis Polymerization (ROMP) Grafting-Through Strategy.

    Science.gov (United States)

    Radzinski, Scott C; Foster, Jeffrey C; Matson, John B

    2016-04-01

    Bottlebrush polymers are synthesized using a tandem ring-opening polymerization (ROP) and ring-opening metathesis polymerization (ROMP) strategy. For the first time, ROP and ROMP are conducted sequentially in the same pot to yield well-defined bottlebrush polymers with molecular weights in excess of 10(6) Da. The first step of this process involves the synthesis of a polylactide macromonomer (MM) via ROP of d,l-lactide initiated by an alcohol-functionalized norbornene. ROMP grafting-through is then carried out in the same pot to produce the bottlebrush polymer. The applicability of this methodology is evaluated for different MM molecular weights and bottlebrush backbone degrees of polymerization. Size-exclusion chromatographic and (1)H NMR spectroscopic analyses confirm excellent control over both polymerization steps. In addition, bottlebrush polymers are imaged using atomic force microscopy and stain-free transmission electron microscopy on graphene oxide. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Open-angle glaucoma in patients with diabetic retinopathy at the Puerto Rico Medical Center.

    Science.gov (United States)

    Cruz-lñigo, Yousef; Izquierdo, Natalio J; García, Omar; Pérez, Raúl

    2012-01-01

    The association of open-angle glaucoma (OAG) with diabetes mellitus remains controversial. We report on the frequency of open-angle glaucoma in patients having diabetic retinopathy in a population of the Puerto Rico Medical Center. A cross-sectional study of 1,442 patients was done. Only the chart of patients 40 years-of-age and older, with a diagnosis of diabetic retinopathy and/or open-angle glaucoma were included. Descriptive analysis was done. Unadjusted and gender-adjusted logistic regression analyses were used to estimate risk of developing open-angle glaucoma in patients with diabetic retinopathy for each subsequent decade. 1,040 patients were diagnosed with diabetic retinopathy from July 1, 2004 to June 30, 2009. Also, 402 patients were diagnosed with open-angle glaucoma from July 1, 2007 to June 30, 2009. Of the 1,040 patients with diabetic retinopathy, 64 patients (6.15%) also had OAG. According to our gender-adjusted logistic regression analysis the estimated risk of developing open-angle glaucoma for patients 40 years-of-age with diabetic retinopathy increased for each subsequent decade until the seventh decade, odds ratio = 5.07 (95% confidence interval: 1.62-15.86). Thereafter, it decreased, odds ratio = 2.07 (95% confidence interval: 0.36-11.82). Our findings suggest that Puerto Rico patients between 40 to 79 years of age with diabetic retinopathy have an increased risk of developing open-angle glaucoma with each subsequent decade. Screening for open-angle glaucoma in patients with diabetic retinopathy is of utmost importance in the aging Puerto Rico population to prevent blindness.

  16. Radar imaging of Saturn's rings

    Science.gov (United States)

    Nicholson, Philip D.; French, Richard G.; Campbell, Donald B.; Margot, Jean-Luc; Nolan, Michael C.; Black, Gregory J.; Salo, Heikki J.

    2005-09-01

    We present delay-Doppler images of Saturn's rings based on radar observations made at Arecibo Observatory between 1999 and 2003, at a wavelength of 12.6 cm and at ring opening angles of 20.1°⩽|B|⩽26.7°. The average radar cross-section of the A ring is ˜77% relative to that of the B ring, while a stringent upper limit of 3% is placed on the cross-section of the C ring and 9% on that of the Cassini Division. These results are consistent with those obtained by Ostro et al. [1982, Icarus 49, 367-381] from radar observations at |B|=21.4°, but provide higher resolution maps of the rings' reflectivity profile. The average cross-section of the A and B rings, normalized by their projected unblocked area, is found to have decreased from 1.25±0.31 to 0.74±0.19 as the rings have opened up, while the circular polarization ratio has increased from 0.64±0.06 to 0.77±0.06. The steep decrease in cross-section is at variance with previous radar measurements [Ostro et al., 1980, Icarus 41, 381-388], and neither this nor the polarization variations are easily understood within the framework of either classical, many-particle-thick or monolayer ring models. One possible explanation involves vertical size segregation in the rings, whereby observations at larger elevation angles which see deeper into the rings preferentially see the larger particles concentrated near the rings' mid-plane. These larger particles may be less reflective and/or rougher and thus more depolarizing than the smaller ones. Images from all four years show a strong m=2 azimuthal asymmetry in the reflectivity of the A ring, with an amplitude of ±20% and minima at longitudes of 67±4° and 247±4° from the sub-Earth point. We attribute the asymmetry to the presence of gravitational wakes in the A ring as invoked by Colombo et al. [1976, Nature 264, 344-345] to explain the similar asymmetry long seen at optical wavelengths. A simple radiative transfer model suggests that the enhancement of the azimuthal

  17. Multi-level Quantum Mechanics and Molecular Mechanics Study of Ring Opening Process of Guanine Damage by Hydroxyl Radical in Aqueous Solution.

    Science.gov (United States)

    Liu, Peng; Wang, Qiong; Niu, Meixing; Wang, Dunyou

    2017-08-10

    Combining multi-level quantum mechanics theories and molecular mechanics with an explicit water model, we investigated the ring opening process of guanine damage by hydroxyl radical in aqueous solution. The detailed, atomic-level ring-opening mechanism along the reaction pathway was revealed in aqueous solution at the CCSD(T)/MM levels of theory. The potentials of mean force in aqueous solution were calculated at both the DFT/MM and CCSD(T)/MM levels of the theory. Our study found that the aqueous solution has a significant effect on this reaction in solution. In particular, by comparing the geometries of the stationary points between in gas phase and in aqueous solution, we found that the aqueous solution has a tremendous impact on the torsion angles much more than on the bond lengths and bending angles. Our calculated free-energy barrier height 31.6 kcal/mol at the CCSD(T)/MM level of theory agrees well with the one obtained based on gas-phase reaction profile and free energies of solvation. In addition, the reaction path in gas phase was also mapped using multi-level quantum mechanics theories, which shows a reaction barrier at 19.2 kcal/mol at the CCSD(T) level of theory, agreeing very well with a recent ab initio calculation result at 20.8 kcal/mol.

  18. On the evolution of jet energy and opening angle in strongly coupled plasma

    International Nuclear Information System (INIS)

    Chesler, Paul M.; Rajagopal, Krishna

    2016-01-01

    We calculate how the energy and the opening angle of jets in N=4 SYM theory evolve as they propagate through the strongly coupled plasma of that theory. We define the rate of energy loss dE_j_e_t/dx and the jet opening angle in a straightforward fashion directly in the gauge theory before calculating both holographically, in the dual gravitational description. In this way, we rederive the previously known result for dE_j_e_t/dx without the need to introduce a finite slab of plasma. We obtain a striking relationship between the initial opening angle of the jet, which is to say the opening angle that it would have had if it had found itself in vacuum instead of in plasma, and the thermalization distance of the jet. Via this relationship, we show that N=4 SYM jets with any initial energy that have the same initial opening angle and the same trajectory through the plasma experience the same fractional energy loss. We also provide an expansion that describes how the opening angle of the N=4 SYM jets increases slowly as they lose energy, over the fraction of their lifetime when their fractional energy loss is not yet large. We close by looking ahead toward potential qualitative lessons from our results for QCD jets produced in heavy collisions and propagating through quark-gluon plasma.

  19. Effects of different reaction mediums on ring opening polymerization ...

    African Journals Online (AJOL)

    This work examined the effects of reaction conditions on ring opening ... of this study was to observe molecular weight distribution, conversion rates, and thermal ... M monomer and 0.56 M solvent), 10 mg lipase were used in the experiments.

  20. In situ ring-opening polymerization of hydroxyapatite/poly (ethylene ...

    Indian Academy of Sciences (India)

    2016-08-26

    Aug 26, 2016 ... Hydroxyapatite/poly(ethylene adipate)--poly(ethylene terephthalate) biomaterials (HAp/PEA--PET) have been prepared by ring opening polymerization (ROP) of cyclic oligo(ethylene adipate)--oligo(ethylene terephthalate) (C-OEA--C-OET) in the porous hydroxyapatite (HAp) scaffolds at 250 ...

  1. Topological optimization of opening fence brackets on ring-stiffened cylindrical shell

    Directory of Open Access Journals (Sweden)

    SONG Xiaofei

    2018-02-01

    Full Text Available [Objectives] Stress concentration is prone to take place at connections between the opening fence and ring ribs of a ring-stiffened cylindrical shell under external pressure. [Methods] In this paper, a topological optimization method for the brackets that connect the fence to the ring ribs is proposed in order to effectively reduce the local high stress in the brackets. The sub-model technique is used to analyze the stress of the connecting brackets. In the design, the connection brackets are used as design variables and the stress of the shell, fence and ribs are used as constraints. The maximum stress of the bracket is minimized as the objective function. The topology optimization results are engineered to obtain the final form of the brackets. [Results] The calculation results show that brackets of which the panel is partially widened can effectively reduce the stress concentration position of the opening fence transverse offset if the side of the bracket away from the longitudinal section is longer; the opening fence is offset relative to the brackets, and the symmetrical design of the brackets is feasible. [Conclusions] This research provides a reference for similar structural design.

  2. Computational study of hydrogen shifts and ring-opening mechanisms in α-pinene ozonolysis products

    DEFF Research Database (Denmark)

    Kurtén, Theo; Rissanen, Matti P.; Mackeprang, Kasper

    2015-01-01

    , sterically unhindered) H-shifts of all four peroxy radicals formed in the ozonolysis of α-pinene using density functional (ωB97XD) and coupled cluster [CCSD(T)-F12] theory. In contrast to the related but chemically simpler cyclohexene ozonolysis system, none of the calculated H-shifts have rate constants...... products in the α-pinene ozonolysis system, additional ring-opening reaction mechanisms breaking the cyclobutyl ring are therefore needed. We further investigate possible uni- and bimolecular pathways for opening the cyclobutyl ring in the α-pinene ozonolysis system....

  3. Selective Ring Opening of 1-Methylnaphthalene Over NiW-Supported Catalyst Using Dealuminated Beta Zeolite.

    Science.gov (United States)

    Kim, Eun-Sang; Lee, You-Jin; Kim, Jeong-Rang; Kim, Joo-Wan; Kim, Tae-Wan; Chae, Ho-Jeong; Kim, Chul-Ung; Lee, Chang-Ha; Jeong, Soon-Yong

    2016-02-01

    Nanoporous Beta zeolite was dealuminated by weak acid treatment for reducing the acidity. Bi-functional catalysts were prepared using commercial Beta zeolites and the dealuminated zeolites for acidic function, NiW for metallic function. 1-Methylnaphthalene was selected as a model compound for multi-ring aromatics in heavy oil, and its selective ring opening reaction has been investigated using the prepared bi-functional catalysts with different acidity in fixed bed reaction system. The dealuminated Beta zeolites, which crystal structure and nanoporosity were maintained, showed the higher SiO2/Al2O3 ratio and smaller acidity than their original zeolite. NiW-supported catalyst using the dealuminated Beta zeolite with SiO2/Al203 mole ratio of 55 showed the highest performance for the selective ring opening. The acidity of catalyst seemed to play an important role as active sites for the selective ring opening of 1-methylnaphthalene but there should be some optimum catalyst acidity for the reaction. The acidity of Beta zeolite could be controlled by the acid treatment and the catalyst with the optimum acidity for the selective ring opening could be prepared.

  4. Economic impact of primary open-angle glaucoma in Australia.

    Science.gov (United States)

    Dirani, Mohamed; Crowston, Jonathan G; Taylor, Penny S; Moore, Peter T; Rogers, Sophie; Pezzullo, M Lynne; Keeffe, Jill E; Taylor, Hugh R

    2011-01-01

    Glaucoma is the World's leading cause of irreversible blindness, and poses serious public health and economic concerns.   Review. Published randomized trials and population-based studies since 1985. We report the economic impact of primary open-angle glaucoma and model the effect of changes in detection rates and management strategies. The cost-effectiveness of different interventions to prevent vision loss from primary open-angle glaucoma was measured in terms of financial cost (Australian dollars) and disability-adjusted life years. The prevalence of glaucoma in Australia is expected to increase from 208 000 in 2005 to 379 000 in 2025 because of the aging population. Health system costs over the same time period are estimated to increase from $AU355 million to $AU784 million. Total costs (health system costs, indirect costs and costs of loss of well-being) will increase from $AU1.9 billion to $AU4.3 billion in Australia. Primary open-angle glaucoma poses a significant economic burden, which will increase substantially by 2025. This dynamic model provides a valuable tool for ongoing policy formulation and determining the economic impact of interventions to better prevent visual impairment and blindness from glaucoma. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.

  5. Lorentz angle studies for the SLD endcap Cerenkov Ring Imaging Detector

    International Nuclear Information System (INIS)

    Coyle, P.; Cavalli-Sforza, M.; Coyne, D.

    1987-11-01

    The design of the endcap Cerenkov Ring Imaging Detectors for SLD requires a detailed understanding of how electrons drift in gases under the influence of crossed electric and magnetic fields. In this report, we present recent measurements of Lorentz angles and drift velocities in gases suitable for the endcap CRID photon detectors. We compare these measurements to predictions from a theoretical model; good agreement is observed. Based on our results we present a design for detectors operating in a 0.6 Tesla transverse magnetic field. 14 refs., 10 figs., 4 tabs

  6. In situ ring-opening polymerization of hydroxyapatite/poly (ethylene ...

    Indian Academy of Sciences (India)

    Hydroxyapatite/poly(ethylene adipate)--poly(ethylene terephthalate) biomaterials (HAp/PEA--PET) have been prepared by ring opening polymerization (ROP) of cyclic oligo(ethylene adipate)--oligo(ethylene terephthalate) (C-OEA--C-OET) in the porous hydroxyapatite (HAp) scaffolds at 250 °C for 24 h under ...

  7. Research progress on related genes for primary open angle glaucoma

    Directory of Open Access Journals (Sweden)

    Ailijiang·Aierken

    2014-04-01

    Full Text Available Primary open angle glaucoma(POAGis the main cause of blindness with visual field damage and optic nerve degeneration. In recent years, a lot of researches have been done, showing that genetic factors and gene mutation play an important role in POAG. There are more than 20 related POAG genes. Now we will review the related genes of POAG, especially the well known causative genes of MYOC, OPTN, WDR36, and CAV1/CAV2, in terms of their locations, structures, research progress, et al, and provide a reference for genetic research in primary open-angle glaucoma.

  8. Recent Advances in Ring-Opening Functionalization of Cycloalkanols by C-C σ-Bond Cleavage.

    Science.gov (United States)

    Wu, Xinxin; Zhu, Chen

    2018-06-01

    Cycloalkanols prove to be privileged precursors for the synthesis of distally substituted alkyl ketones and polycyclic aromatic hydrocarbons (PAHs) by virtue of cleavage of their cyclic C-C bonds. Direct functionalization of cyclobutanols to build up other chemical bonds (e. g., C-F, C-Cl, C-Br, C-N, C-S, C-Se, C-C, etc.) has been achieved by using the ring-opening strategy. Mechanistically, the C-C cleavage of cyclobutanols can be involved in two pathways: (a) transition-metal catalyzed β-carbon elimination; (b) radical-mediated 'radical clock'-type ring opening. The recent advances of our group for the ring-opening functionalization of tertiary cycloalkanols are described in this account. © 2018 The Chemical Society of Japan & Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Using Ring Strain to Control 4π-Electrocyclization Reactions: Torquoselectivity in Ring Closing of Medium-Ring Dienes and Ring Opening of Bicyclic Cyclobutenes.

    Science.gov (United States)

    Boon, Byron A; Green, Aaron G; Liu, Peng; Houk, K N; Merlic, Craig A

    2017-05-05

    Syntheses of strained cyclic dienes were accomplished via palladium(II)-catalyzed oxidative cyclizations of terminal bis(vinylboronate esters). The reactions generate strained (E,E)-1,3-dienes that undergo spontaneous 4π-electrocyclizations to form bicyclic cyclobutenes. Formation of the cyclobutenes is driven by the strain in the medium-ring (E,E)-1,3-diene intermediate. Thermal ring openings of the cyclobutenes give (Z,Z)-1,3-diene products, again for thermodynamic reasons. DFT calculations verified the thermodynamic versus kinetic control of the reactions, and kinetic studies are in excellent agreement with the calculated energy changes. An extension of the tandem coupling/4π-electrocyclization pathway was demonstrated by a palladium(II)-catalyzed oxidative homocoupling/8π-electrocyclization cascade.

  10. Synthesis of benzamides by microwave assisted ring opening of less reactive dimethylaminobenzylidene oxazolone

    Directory of Open Access Journals (Sweden)

    Saurabh C. Khadse

    2017-02-01

    Full Text Available This paper presents the synthesis of some benzamide compounds (B1–B10 by microwave-assisted ring opening of 4-(4-dimethylaminobenzylidene-2-phenyl-5-oxazolone (AZ4. By conventional synthesis involving heating, it was found difficult to obtain ring-opened products, probably due to poor tendency of the carbonyl carbon (C5 of AZ4 to undergo nucleophilic attack by mono/or disubstituted anilines. Microwave assisted reactions were easy to perform, have reduced the reaction time and produced good yields.

  11. Visual Disability Among Juvenile Open-angle Glaucoma Patients.

    Science.gov (United States)

    Gupta, Viney; Ganesan, Vaitheeswaran L; Kumar, Sandip; Chaurasia, Abadh K; Malhotra, Sumit; Gupta, Shikha

    2018-04-01

    Juvenile onset primary open-angle glaucoma (JOAG) unlike adult onset primary open-angle glaucoma presents with high intraocular pressure and diffuse visual field loss, which if left untreated leads to severe visual disability. The study aimed to evaluate the extent of visual disability among JOAG patients presenting to a tertiary eye care facility. Visual acuity and perimetry records of unrelated JOAG patients presenting to our Glaucoma facility were analyzed. Low vision and blindness was categorized by the WHO criteria and percentage impairment was calculated as per the guidelines provided by the American Medical Association (AMA). Fifty-two (15%) of the 348 JOAG patients were bilaterally blind at presentation and 32 (9%) had low vision according to WHO criteria. Ninety JOAG patients (26%) had a visual impairment of 75% or more. Visual disability at presentation among JOAG patients is high. This entails a huge economic burden, given their young age and associated social responsibilities.

  12. Molecular complexity of primary open angle glaucoma: current ...

    Indian Academy of Sciences (India)

    2009-12-31

    Dec 31, 2009 ... ment nor does it develop any glaucomatous phenotype (Kim ... vestigial genomic region; only to cause harm in case of any .... level, current knowledge of genetic studies suggests that the ...... rizes the unfolding network of events in primary open angle glaucoma (POAG) and has been created based on the ...

  13. Quantum Mechanics/Molecular Mechanics Simulations Identify the Ring-Opening Mechanism of Creatininase.

    Science.gov (United States)

    Jitonnom, Jitrayut; Mujika, Jon I; van der Kamp, Marc W; Mulholland, Adrian J

    2017-12-05

    Creatininase catalyzes the conversion of creatinine (a biosensor for kidney function) to creatine via a two-step mechanism: water addition followed by ring opening. Water addition is common to other known cyclic amidohydrolases, but the precise mechanism for ring opening is still under debate. The proton donor in this step is either His178 or a water molecule bound to one of the metal ions, and the roles of His178 and Glu122 are unclear. Here, the two possible reaction pathways have been fully examined by means of combined quantum mechanics/molecular mechanics simulations at the SCC-DFTB/CHARMM22 level of theory. The results indicate that His178 is the main catalytic residue for the whole reaction and explain its role as proton shuttle during the ring-opening step. In the first step, His178 provides electrostatic stabilization to the gem-diolate tetrahedral intermediate. In the second step, His178 abstracts the hydroxyl proton of the intermediate and delivers it to the cyclic amide nitrogen, leading to ring opening. The latter is the rate-limiting step with a free energy barrier of 18.5 kcal/mol, in agreement with the experiment. We find that Glu122 must be protonated during the enzyme reaction, so that it can form a stable hydrogen bond with its neighboring water molecule. Simulations of the E122Q mutant showed that this replacement disrupts the H-bond network formed by three conserved residues (Glu34, Ser78, and Glu122) and water, increasing the energy barrier. Our computational studies provide a comprehensive explanation for previous structural and kinetic observations, including why the H178A mutation causes a complete loss of activity but the E122Q mutation does not.

  14. Preparation of nucleoside-pyridine hybrids and pyridine attached acylureas from an unexpected uracil ring-opening and pyridine ring-forming sequence

    Institute of Scientific and Technical Information of China (English)

    Xue Sen Fan; Xia Wang; Xin Ying Zhang; Dong Feng; Ying Ying Qu

    2009-01-01

    Novel pyrimidine nucleoside-3,5-dicyanopyridine hybrids (4) or pyridine attached acylureas (5) were selectively and efficiently prepared from the reaction of 2'-deoxyuridin-5-yl-methylene malonortitrile (1), malononitrile (2) and thiophenol (3) or from an unexpected uracil ring-opening and pyridine ring-forming sequence via the reaction of 1 and 3. It is the first time such a sequence has ever been reported.

  15. Liberation of methyl acrylate from metallalactone complexes via M-O ring opening (M = Ni, Pd) with methylation agents

    KAUST Repository

    Lee, S. Y Tina; Ghani, Amylia Abdul; D'Elia, Valerio; Cokoja, Mirza; Herrmann, Wolfgang A.; Basset, Jean-Marie; Kü hn, Fritz

    2013-01-01

    Ring opening of various nickela- and palladalactones induced by the cleavage of the M-O bond by methyl trifluoromethanesulfonate (MeOTf) and methyl iodide (MeI) is examined. Experimental evidence supports the mechanism of ring opening by the alkylating agent followed by β-H elimination leading to methyl acrylate and a metal-hydride species. MeOTf shows by far higher efficiency in the lactone ring opening than any other methylating agent including the previously reported methyl iodide. © 2013 The Royal Society of Chemistry and the Centre National de la Recherche Scientifique.

  16. Opening a spiropyran ring by way of an exciplex intermediate.

    Science.gov (United States)

    Benniston, Andrew C; Harriman, Anthony; Howell, Sarah L; Li, Peiyi; Lydon, Donocadh P

    2007-02-02

    A molecular dyad has been synthesized in which the main chromophore is a 1,4-diethynylated benzene residue terminated with pyrene moieties, this latter unit acting as a single chromophore. A spiropyran group has been condensed to the central phenylene ring so as to position a weak electron donor close to the pyrene unit. Illumination of the pyrene-based chromophore leads to formation of a fluorescent exciplex in polar solvents but pyrene-like fluorescence is observed in nonpolar solvents. The exciplex has a lifetime of a few nanoseconds and undergoes intersystem crossing to the pyrene-like triplet state with low efficiency. Attaching a 4-nitrobenzene group to the open end of the spiropyran unit creates a new route for decay of the exciplex whereby the triplet state of the spiropyran is formed. Nonradiative decay of this latter species results in ring opening to form the corresponding merocyanine species. Rate constants for the various steps have been obtained from time-resolved fluorescence spectroscopy carried out over a modest temperature range. Under visible light illumination, the merocyanine form reverts to the original spiropyran geometry so that the cycle is closed. Energy transfer from the pyrene chromophore to the merocyanine unit leads to an increased rate of ring closure and serves to push the steady-state composition in favor of the spiropyran form.

  17. Impaired Saccadic Eye Movement in Primary Open-angle Glaucoma

    DEFF Research Database (Denmark)

    Lamirel, Cédric; Milea, Dan; Cochereau, Isabelle

    2013-01-01

    PURPOSE:: Our study aimed at investigating the extent to which saccadic eye movements are disrupted in patients with primary open-angle glaucoma (POAG). This approach followed upon the discovery of differences in the eye-movement behavior of POAG patients during the exploration of complex visual...

  18. Measurement of small-angle antiproton-proton and proton-proton elastic scattering at the CERN intersecting storage rings

    NARCIS (Netherlands)

    Amos, N.; Block, M.M.; Bobbink, G.J.; Botje, M.A.J.; Favart, D.; Leroy, C.; Linde, F.; Lipnik, P.; Matheys, J-P.; Miller, D.

    1985-01-01

    Antiproton-proton and proton-proton small-angle elastic scattering was measured for centre-of-mass energies at the CERN Intersectung Storage Rings. In addition, proton-proton elastic scattering was measured at . Using the optical theorem, total cross sections are obtained with an accuracy of about

  19. Adsorption and ring-opening of lactide on the chiral metal surface Pt(321){sup S} studied by density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Franke, J.-H.; Kosov, D. S. [Department of Physics, Campus Plaine - CP 231, Universite Libre de Bruxelles, 1050 Brussels (Belgium)

    2015-01-28

    We study the adsorption and ring-opening of lactide on the naturally chiral metal surface Pt(321){sup S}. Lactide is a precursor for polylactic acid ring-opening polymerization, and Pt is a well known catalyst surface. We study, here, the energetics of the ring-opening of lactide on a surface that has a high density of kink atoms. These sites are expected to be present on a realistic Pt surface and show enhanced catalytic activity. The use of a naturally chiral surface also enables us to study potential chiral selectivity effects of the reaction at the same time. Using density functional theory with a functional that includes the van der Waals forces in a first-principles manner, we find modest adsorption energies of around 1.4 eV for the pristine molecule and different ring-opened states. The energy barrier to be overcome in the ring-opening reaction is found to be very small at 0.32 eV and 0.30 eV for LL- and its chiral partner DD-lactide, respectively. These energies are much smaller than the activation energy for a dehydrogenation reaction of 0.78 eV. Our results thus indicate that (a) ring-opening reactions of lactide on Pt(321) can be expected already at very low temperatures, and Pt might be a very effective catalyst for this reaction; (b) the ring-opening reaction rate shows noticeable enantioselectivity.

  20. Synthesis and ring openings of cinnamate-derived N-unfunctionalised aziridines

    Directory of Open Access Journals (Sweden)

    Alan Armstrong

    2012-10-01

    Full Text Available tert-Butyl cinnamates are aziridinated with high trans-selectivity by an N–N ylide generated in situ from N-methylmorpholine and O-diphenylphosphinyl hydroxylamine. The resulting N-unfunctionalised aziridines are shown to be versatile synthetic building blocks that undergo highly selective ring-opening reactions with a wide range of nucleophiles.

  1. Ring opening of a resin-bound chiral aziridine with phenol nucleophiles

    DEFF Research Database (Denmark)

    Ottesen, Lars Korsgaard; Jaroszewski, Jerzy W; Franzyk, Henrik

    2010-01-01

    An efficient and versatile solid-phase route for the preparation of aryl-alkyl ethers is described. Regioselective ring opening of a resin-bound chiral aziridine with phenolic nucleophiles constitutes the key feature of the present protocol that allows incorporation of fluorescent moieties...

  2. Functional polypeptides obtained by living ring opening polymerizations of N-carboxyanhydrides

    NARCIS (Netherlands)

    Habraken, G.J.M.

    2011-01-01

    N-Carboxyanhydride ring opening polymerization (NCA ROP) is a method to prepare polypeptides with a high degree of polymerization in large quantities. The living polymerization technique of NCA ROP gave the opportunity to synthesize many polymer architectures with well-defined blocks and copolymers

  3. Open angle glaucoma as a manifestation of Waardenburg′s syndrome.

    Directory of Open Access Journals (Sweden)

    Gupta Viney

    2000-01-01

    Full Text Available Waardenburg′s syndrome is a rare, autosomal dominant disorder, with several clinical signs, each with variable penetrance. We report this case of Waardenburg′s syndrome with bilateral open-angle glaucoma with unique gonioscopic findings.

  4. Visual disability in Newly Diagnosed Primary open Angle Glaucoma ...

    African Journals Online (AJOL)

    Background: Glaucoma remains the second leading cause of blindness worldwide and the highest cause of irreversible blindness worldwide. In Nigeria, Glaucoma accounts for 16% of blindness and primary open angle glaucoma is the most prevalent clinical type. Aim: The aim of this study is to assess the visual disability ...

  5. Long Term Results of Visual Field Progression Analysis in Open Angle Glaucoma Patients Under Treatment.

    Science.gov (United States)

    Kocatürk, Tolga; Bekmez, Sinan; Katrancı, Merve; Çakmak, Harun; Dayanır, Volkan

    2015-01-01

    To evaluate visual field progression with trend and event analysis in open angle glaucoma patients under treatment. Fifteen year follow-up results of 408 eyes of 217 glaucoma patients who were followed at Adnan Menderes University, Department of Ophthalmology between 1998 and 2013 were analyzed retrospectively. Visual field data were collected for Mean Deviation (MD), Visual Field Index (VFI), and event occurrence. There were 146 primary open-angle glaucoma (POAG), 123 pseudoexfoliative glaucoma (XFG) and 139 normal tension glaucoma (NTG) eyes. MD showed significant change in all diagnostic groups (pfield indices. We herein report our fifteen year follow-up results in open angle glaucoma.

  6. Thermodynamic Presynthetic Considerations for Ring-Opening Polymerization.

    Science.gov (United States)

    Olsén, Peter; Odelius, Karin; Albertsson, Ann-Christine

    2016-03-14

    The need for polymers for high-end applications, coupled with the desire to mimic nature's macromolecular machinery fuels the development of innovative synthetic strategies every year. The recently acquired macromolecular-synthetic tools increase the precision and enable the synthesis of polymers with high control and low dispersity. However, regardless of the specificity, the polymerization behavior is highly dependent on the monomeric structure. This is particularly true for the ring-opening polymerization of lactones, in which the ring size and degree of substitution highly influence the polymer formation properties. In other words, there are two important factors to contemplate when considering the particular polymerization behavior of a specific monomer: catalytic specificity and thermodynamic equilibrium behavior. This perspective focuses on the latter and undertakes a holistic approach among the different lactones with regard to the equilibrium thermodynamic polymerization behavior and its relation to polymer synthesis. This is summarized in a monomeric overview diagram that acts as a presynthetic directional cursor for synthesizing highly specific macromolecules; the means by which monomer equilibrium conversion relates to starting temperature, concentration, ring size, degree of substitution, and its implications for polymerization behavior are discussed. These discussions emphasize the importance of considering not only the catalytic system but also the monomer size and structure relations to thermodynamic equilibrium behavior. The thermodynamic equilibrium behavior relation with a monomer structure offers an additional layer of complexity to our molecular toolbox and, if it is harnessed accordingly, enables a powerful route to both monomer formation and intentional macromolecular design.

  7. Supported Catalysts Useful in Ring-Closing Metathesis, Cross Metathesis, and Ring-Opening Metathesis Polymerization

    Directory of Open Access Journals (Sweden)

    Jakkrit Suriboot

    2016-04-01

    Full Text Available Ruthenium and molybdenum catalysts are widely used in synthesis of both small molecules and macromolecules. While major developments have led to new increasingly active catalysts that have high functional group compatibility and stereoselectivity, catalyst/product separation, catalyst recycling, and/or catalyst residue/product separation remain an issue in some applications of these catalysts. This review highlights some of the history of efforts to address these problems, first discussing the problem in the context of reactions like ring-closing metathesis and cross metathesis catalysis used in the synthesis of low molecular weight compounds. It then discusses in more detail progress in dealing with these issues in ring opening metathesis polymerization chemistry. Such approaches depend on a biphasic solid/liquid or liquid separation and can use either always biphasic or sometimes biphasic systems and approaches to this problem using insoluble inorganic supports, insoluble crosslinked polymeric organic supports, soluble polymeric supports, ionic liquids and fluorous phases are discussed.

  8. Copper-catalyzed asymmetric ring opening of oxabicyclic alkenes with organolithium reagents

    NARCIS (Netherlands)

    Bos, Pieter H.; Rudolph, Alena; Pérez, Manuel; Fañanás-Mastral, Martín; Harutyunyan, Syuzanna R.; Feringa, Bernard

    2012-01-01

    A highly efficient method is reported for the asymmetric ring opening of oxabicyclic alkenes with organolithium reagents. Using a copper/chiral phosphoramidite complex together with a Lewis acid (BF3·OEt2), full selectivity for the anti isomer and excellent enantioselectivities were obtained for the

  9. Anterior segment parameters as predictors of intraocular pressure reduction after phacoemulsification in eyes with open-angle glaucoma.

    Science.gov (United States)

    Hsia, Yen C; Moghimi, Sasan; Coh, Paul; Chen, Rebecca; Masis, Marisse; Lin, Shan C

    2017-07-01

    To evaluate intraocular pressure (IOP) change after cataract surgery in eyes with open-angle glaucoma (OAG) and its relationship to angle and anterior segment parameters measured by anterior segment optical coherence tomography (AS-OCT). University of California, San Francisco, California, USA. Prospective case series. Eyes were placed into a narrow-angle group or open-angle group based on gonioscopy grading. Biometric parameters were measured using AS-OCT (Visante) preoperatively, and IOP 4 months after surgery was obtained. The IOP change and its relationship to AS-OCT parameters were evaluated. Eighty-one eyes of 69 patients were enrolled. The mean age of the patients was 76.8 years. The preoperative IOP was 15.02 mm Hg on 1.89 glaucoma medications. The average mean deviation of preoperative visual field was -4.58 dB. The mean IOP reduction was 2.1 mm Hg (12.8%) from a preoperative mean of 15.0 mm Hg. The IOP reduction was significantly greater in eyes with narrow angles than in eyes with open angles (20.4% versus 8.0%) (P = .002). In multivariate analysis, preoperative IOP (β = -0.53, P < .001, R 2  = 0.40), angle-opening distance at 500 mm (β = 5.83, P = .02, R 2  = 0.45), angle-opening distance at 750 mm (β = 5.82, P = .001, R 2  = 0.52), and lens vault (β = -0.002, P = .009, R 2  = 0.47) were associated with IOP reduction postoperatively. In eyes with OAG, IOP reduction after cataract surgery was greater in eyes with narrower angles. Preoperative IOP, angle-opening distance, and lens vault were predictors for IOP reduction. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Microdroplets Accelerate Ring Opening of Epoxides

    Science.gov (United States)

    Lai, Yin-Hung; Sathyamoorthi, Shyam; Bain, Ryan M.; Zare, Richard N.

    2018-05-01

    The nucleophilic opening of an epoxide is a classic organic reaction that has widespread utility in both academic and industrial applications. We have studied the reaction of limonene oxide with morpholine to form 1-methyl-2-morpholino-4-(prop-1-en-2-yl) cyclohexan-1-ol in bulk solution and in electrosprayed microdroplets with a 1:1 v/ v water/methanol solvent system. We find that even after 90 min at room temperature, there is no product detected by nuclear magnetic resonance spectroscopy in bulk solution whereas in room-temperature microdroplets (2-3 μm in diameter), the yield is already 0.5% in a flight time of 1 ms as observed by mass spectrometry. This constitutes a rate acceleration of 105 in the microdroplet environment, if we assume that as much as 5% of product is formed in bulk after 90 min of reaction time. We examine how the reaction rate depends on droplet size, solvent composition, sheath gas pressure, and applied voltage. These factors profoundly influence the extent of reaction. This dramatic acceleration is not limited to just one system. We have also found that the nucleophilic opening of cis-stilbene oxide by morpholine is similarly accelerated. Such large acceleration factors in reaction rates suggest the use of microdroplets for ring opening of epoxides in other systems, which may have practical significance if such a procedure could be scaled. [Figure not available: see fulltext.

  11. Microdroplets Accelerate Ring Opening of Epoxides

    Science.gov (United States)

    Lai, Yin-Hung; Sathyamoorthi, Shyam; Bain, Ryan M.; Zare, Richard N.

    2018-03-01

    The nucleophilic opening of an epoxide is a classic organic reaction that has widespread utility in both academic and industrial applications. We have studied the reaction of limonene oxide with morpholine to form 1-methyl-2-morpholino-4-(prop-1-en-2-yl) cyclohexan-1-ol in bulk solution and in electrosprayed microdroplets with a 1:1 v/v water/methanol solvent system. We find that even after 90 min at room temperature, there is no product detected by nuclear magnetic resonance spectroscopy in bulk solution whereas in room-temperature microdroplets (2-3 μm in diameter), the yield is already 0.5% in a flight time of 1 ms as observed by mass spectrometry. This constitutes a rate acceleration of 105 in the microdroplet environment, if we assume that as much as 5% of product is formed in bulk after 90 min of reaction time. We examine how the reaction rate depends on droplet size, solvent composition, sheath gas pressure, and applied voltage. These factors profoundly influence the extent of reaction. This dramatic acceleration is not limited to just one system. We have also found that the nucleophilic opening of cis-stilbene oxide by morpholine is similarly accelerated. Such large acceleration factors in reaction rates suggest the use of microdroplets for ring opening of epoxides in other systems, which may have practical significance if such a procedure could be scaled. [Figure not available: see fulltext.

  12. Lasers in primary open angle glaucoma

    Directory of Open Access Journals (Sweden)

    Sihota Ramanjit

    2011-12-01

    Full Text Available Lasers have been used in the treatment of primary open angle glaucoma (POAG over the years, with the hope that they would eventually replace medical and surgical therapy. Laser trabeculoplasty (LT is an application of argon, diode, or selective laser energy to the surface of the trabecular meshwork to increase the aqueous outflow. The mechanisms by which intraocular pressure (IOP is lowered could be mechanical, biologic, or by division of adjacent cells. It is commonly used as an adjunct to medical therapy, but is contraindicated if the angle is obstructed, e.g., peripheral anterior synechia (PAS or developmental glaucomas. About 75% of individuals will show a significant fall in IOP after argon laser trabeculoplasty (ALT, and the response is similar with selective laser trabeculoplasty (SLT. The effects of LT are not always long lasting, with about 10% of individuals showing a rise in IOP with every passing year. Laser thermal sclerostomy, ab interno or externo, is an alternative to other full-thickness filtration procedures. Longer wavelengths in the infrared range have water-absorptive characteristics that facilitate perforation of the sclera. These lasers can be used to avoid intraocular instrumentation and minimize conjunctival trauma.

  13. Green chemistry: Efficient epoxides ring-opening with 1-butanol under microwave irradiation

    International Nuclear Information System (INIS)

    Garcia-Vidal, Jesus A.; Duran-Valle, Carlos J.; Ferrera-Escudero, Santiago

    2006-01-01

    Two activated carbons treated with mineral acids (HNO 3 and sulfonitric mixture) have been tested as acid catalysts in the epoxides (1,2-epoxyhexane and styrene oxide) ring-opening reaction with 1-butanol under microwave (MW) irradiation. The mayor obtained product is that resulting of the alcohol addition to the most substituted carbon in the epoxide ring. The most active catalyst is that treated with sulfonitric mixture. The use of a MW oven allows achieving to the complete conversion of styrene oxide in only 2 min

  14. Green chemistry: Efficient epoxides ring-opening with 1-butanol under microwave irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Vidal, Jesus A. [Departamento de Quimica Inorganica, Facultad de Ciencias, Universidad de Extremadura, Campus Universitario, Avda. de Elvas, s/n, E-06071-Badajoz (Spain); Duran-Valle, Carlos J. [Departamento de Quimica Inorganica, Facultad de Ciencias, Universidad de Extremadura, Campus Universitario, Avda. de Elvas, s/n, E-06071-Badajoz (Spain)]. E-mail: carlosdv@unex.es; Ferrera-Escudero, Santiago [Departamento de Quimica Inorganica y Quimica Tecnica, Universidad Nacional de Educacion a Distancia, C/Senda del Rey, 9, E-28040 Madrid (Spain)

    2006-06-30

    Two activated carbons treated with mineral acids (HNO{sub 3} and sulfonitric mixture) have been tested as acid catalysts in the epoxides (1,2-epoxyhexane and styrene oxide) ring-opening reaction with 1-butanol under microwave (MW) irradiation. The mayor obtained product is that resulting of the alcohol addition to the most substituted carbon in the epoxide ring. The most active catalyst is that treated with sulfonitric mixture. The use of a MW oven allows achieving to the complete conversion of styrene oxide in only 2 min.

  15. Retention of Plasmodium falciparum ring-infected erythrocytes in the slow, open microcirculation of the human spleen.

    Science.gov (United States)

    Safeukui, Innocent; Correas, Jean-Michel; Brousse, Valentine; Hirt, Déborah; Deplaine, Guillaume; Mulé, Sébastien; Lesurtel, Mickael; Goasguen, Nicolas; Sauvanet, Alain; Couvelard, Anne; Kerneis, Sophie; Khun, Huot; Vigan-Womas, Inès; Ottone, Catherine; Molina, Thierry Jo; Tréluyer, Jean-Marc; Mercereau-Puijalon, Odile; Milon, Geneviève; David, Peter H; Buffet, Pierre A

    2008-09-15

    The current paradigm in Plasmodium falciparum malaria pathogenesis states that young, ring-infected erythrocytes (rings) circulate in peripheral blood and that mature stages are sequestered in the vasculature, avoiding clearance by the spleen. Through ex vivo perfusion of human spleens, we examined the interaction of this unique blood-filtering organ with P falciparum-infected erythrocytes. As predicted, mature stages were retained. However, more than 50% of rings were also retained and accumulated upstream from endothelial sinus wall slits of the open, slow red pulp microcirculation. Ten percent of rings were retained at each spleen passage, a rate matching the proportion of blood flowing through the slow circulatory compartment established in parallel using spleen contrast-enhanced ultrasonography in healthy volunteers. Rings displayed a mildly but significantly reduced elongation index, consistent with a retention process, due to their altered mechanical properties. This raises the new paradigm of a heterogeneous ring population, the less deformable subset being retained in the spleen, thereby reducing the parasite biomass that will sequester in vital organs, influencing the risk of severe complications, such as cerebral malaria or severe anemia. Cryptic ring retention uncovers a new role for the spleen in the control of parasite density, opening novel intervention opportunities.

  16. Open-Lake Experimental Investigation of Azimuth Angle Estimation Using a Single Acoustic Vector Sensor

    Directory of Open Access Journals (Sweden)

    Anbang Zhao

    2018-01-01

    Full Text Available Five well-known azimuth angle estimation methods using a single acoustic vector sensor (AVS are investigated in open-lake experiments. A single AVS can measure both the acoustic pressure and acoustic particle velocity at a signal point in space and output multichannel signals. The azimuth angle of one source can be estimated by using a single AVS in a passive sonar system. Open-lake experiments are carried out to evaluate how these different techniques perform in estimating azimuth angle of a source. The AVS that was applied in these open-lake experiments is a two-dimensional accelerometer structure sensor. It consists of two identical uniaxial velocity sensors in orthogonal orientations, plus a pressure sensor—all in spatial collocation. These experimental results indicate that all these methods can effectively realize the azimuth angle estimation using only one AVS. The results presented in this paper reveal that AVS can be applied in a wider range of application in distributed underwater acoustic systems for passive detection, localization, classification, and so on.

  17. A small-angle camera for resonant scattering experiments at the storage ring DORIS

    International Nuclear Information System (INIS)

    Stuhrmann, H.B.; Gabriel, A.

    1983-01-01

    Resonant small-angle scattering is measured routinely in the wavelength range of 0.6 to 3.25 A with the instrument X15 at the storage ring DORIS. The monochromatic beam with a vertical offset of 1.22 m is achieved by a double monochromator system with a constant exit slit. The small-angle instrument allows for sample-detector distances between 0.37 and 7.33 m. A multiwire proportional counter with a sensitive area of 200 X 200 mm detects the scattered intensity with a spatial resolution of 2 X 2 mm. Its sensitivity can be adapted to the requirements of the experiment by activating a drift chamber of 8 cm depth at the back end of the detector. The performance of the instrument as a function of the wavelength is described. The energy resolution is about 1 eV at the L 3 absorption edge of caesium, as shown by the resonant scattering of ferritin in 30% CsCl solution. (Auth.)

  18. Modeling of lipase catalyzed ring-opening polymerization of epsilon-caprolactone.

    Science.gov (United States)

    Sivalingam, G; Madras, Giridhar

    2004-01-01

    Enzymatic ring-opening polymerization of epsilon-caprolactone by various lipases was investigated in toluene at various temperatures. The determination of molecular weight and structural identification was carried out with gel permeation chromatography and proton NMR, respectively. Among the various lipases employed, an immobilized lipase from Candida antartica B (Novozym 435) showed the highest catalytic activity. The polymerization of epsilon-caprolactone by Novozym 435 showed an optimal temperature of 65 degrees C and an optimum toluene content of 50/50 v/v of toluene and epsilon-caprolactone. As lipases can degrade polyesters, a maximum in the molecular weight with time was obtained due to the competition of ring opening polymerization and degradation by specific chain end scission. The optimum temperature, toluene content, and the variation of molecular weight with time are consistent with earlier observations. A comprehensive model based on continuous distribution kinetics was developed to model these phenomena. The model accounts for simultaneous polymerization, degradation and enzyme deactivation and provides a technique to determine the rate coefficients for these processes. The dependence of these rate coefficients with temperature and monomer concentration is also discussed.

  19. Photometric and spectroscopic evidence for a dense ring system around Centaur Chariklo

    Science.gov (United States)

    Duffard, R.; Pinilla-Alonso, N.; Ortiz, J. L.; Alvarez-Candal, A.; Sicardy, B.; Santos-Sanz, P.; Morales, N.; Colazo, C.; Fernández-Valenzuela, E.; Braga-Ribas, F.

    2014-08-01

    Context. A stellar occultation observed on 3rd June 2013 revealed the presence of two dense and narrow rings separated by a small gap around the Centaur object (10 199) Chariklo. The composition of these rings is not known. We suspect that water ice is present in the rings, as is the case for Saturn and other rings around the giant planets. Aims: In this work, we aim to determine if the variability in the absolute magnitude of Chariklo and the temporal variation of the spectral ice feature, even when it disappeared in 2007, can be explained by an icy ring system whose aspect angle changes with time. Methods: We explained the variations on the absolute magnitude of Chariklo and its ring by modeling the light reflected by a system as the one described above. Using X-shooter at VLT, we obtained a new reflectance spectra. We compared this new set of data with the ones available in the literature. We showed how the water ice feature is visible in 2013 in accordance with the ring configuration, which had an opening angle of nearly 34° in 2013. Finally, we also used models of light scattering to fit the visible and near-infrared spectra that shows different characteristics to obtain information on the composition of Chariklo and its rings. Results: We showed that absolute photometry of Chariklo from the literature and new photometric data that we obtained in 2013 can be explained by a ring of particles whose opening angle changes as a function of time. We used the two possible pole solutions for the ring system and found that only one of them, α = 151.30 ± 0.5, δ = 41.48 ± 0.2° (λ = 137.9 ± 0.5, β = 27.7 ± 0.2°), provides the right variation of the aspect angle with time to explain the photometry, whereas the other possible pole solution fails to explain the photometry. From spectral modeling, we derived the composition of the Chariklo surface and that of the rings using the result on the pole solution. Chariklo surface is composed with about 60% of amorphous

  20. Investigation of Blade Angle of an Open Cross-Flow Runner

    Science.gov (United States)

    Katayama, Yusuke; Iio, Shouichiro; Veerapun, Salisa; Uchiyama, Tomomi

    2015-04-01

    The aim of this study was to develop a nano-hydraulic turbine utilizing drop structure in irrigation channels or industrial waterways. This study was focused on an open-type cross-flow turbine without any attached equipment for cost reduction and easy maintenance. In this study, the authors used an artificial indoor waterfall as lab model. Test runner which is a simple structure of 20 circular arc-shaped blades sandwiched by two circular plates was used The optimum inlet blade angle and the relationship between the power performance and the flow rate approaching theoretically and experimentally were investigated. As a result, the optimum inlet blade angle due to the flow rate was changed. Additionally, allocation rate of power output in 1st stage and 2nd stage is changed by the blade inlet angle.

  1. Tank-Binding Kinase 1 (TBK1) Gene and Open-Angle Glaucomas (An American Ophthalmological Society Thesis).

    Science.gov (United States)

    Fingert, John H; Robin, Alan L; Scheetz, Todd E; Kwon, Young H; Liebmann, Jeffrey M; Ritch, Robert; Alward, Wallace L M

    2016-08-01

    To investigate the role of TANK-binding kinase 1 ( TBK1 ) gene copy-number variations (ie, gene duplications and triplications) in the pathophysiology of various open-angle glaucomas. In previous studies, we discovered that copy-number variations in the TBK1 gene are associated with normal-tension glaucoma. Here, we investigated the prevalence of copy-number variations in cohorts of patients with other open-angle glaucomas-juvenile-onset open-angle glaucoma (n=30), pigmentary glaucoma (n=209), exfoliation glaucoma (n=225), and steroid-induced glaucoma (n=79)-using a quantitative polymerase chain reaction assay. No TBK1 gene copy-number variations were detected in patients with juvenile-onset open-angle glaucoma, pigmentary glaucoma, or steroid-induced glaucoma. A TBK1 gene duplication was detected in one (0.44%) of the 225 exfoliation glaucoma patients. TBK1 gene copy-number variations (gene duplications and triplications) have been previously associated with normal-tension glaucoma. An exploration of other open-angle glaucomas detected a TBK1 copy-number variation in a patient with exfoliation glaucoma, which is the first example of a TBK1 mutation in a glaucoma patient with a diagnosis other than normal-tension glaucoma. A broader phenotypic range may be associated with TBK1 copy-number variations, although mutations in this gene are most often detected in patients with normal-tension glaucoma.

  2. Trabecular Meshwork Height in Primary Open-Angle Glaucoma Versus Primary Angle-Closure Glaucoma.

    Science.gov (United States)

    Masis, Marisse; Chen, Rebecca; Porco, Travis; Lin, Shan C

    2017-11-01

    To determine if trabecular meshwork (TM) height differs between primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG) eyes. Prospective, cross-sectional clinical study. Adult patients were consecutively recruited from glaucoma clinics at the University of California, San Francisco, from January 2012 to July 2015. Images were obtained from spectral-domain optical coherence tomography (Cirrus OCT; Carl Zeiss Meditec, Inc, Dublin, California, USA). Univariate and multivariate linear mixed models comparing TM height and glaucoma type were performed to assess the relationship between TM height and glaucoma subtype. Mixed-effects regression was used to adjust for the use of both eyes in some subjects. The study included 260 eyes from 161 subjects, composed of 61 men and 100 women. Mean age was 70 years (SD 11.77). There were 199 eyes (123 patients) in the POAG group and 61 eyes (38 patients) in the PACG group. Mean TM heights in the POAG and PACG groups were 812 ± 13 μm and 732 ± 27 μm, respectively, and the difference was significant in univariate analysis (P = .004) and in multivariate analysis (β = -88.7 [24.05-153.5]; P = .008). In this clinic-based population, trabecular meshwork height is shorter in PACG patients compared to POAG patients. This finding may provide insight into the pathophysiology of angle closure and provide assistance in future diagnosis, prevention, and management of the angle-closure spectrum of disorders. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Sulfuric acid as a catalyst for ring-opening of biobased bis-epoxides

    Science.gov (United States)

    Vegetable oils can be relatively and easily transformed into bio-based epoxides. Because of this, the acid-catalyzed epoxide ring-opening has been explored for the preparation of bio-based lubricants and polymers. Detailed model studies are carried out only with mono-epoxide made from methyl oleate,...

  4. Regioselective Nucleophilic Ring Opening of Epoxides and Aziridines derived from Homoallylic Alcohols

    DEFF Research Database (Denmark)

    Tanner, David Ackland; Groth, Thomas

    1997-01-01

    The regioselectivity of nucleophilic ring opening of some 3,4-epoxy and 3,4-aziridino alcohols has been studied. The nucleophiles chosen were complex hydrides (LiAlH4, Red-Al and DIBAL) and Lipshutz- or Gilman-type organocuprate reagents. The C-4 substituent in the substrates was varied in order...... to study steric and electronic effects on the ring opening reactions. For alkyl substituents at C-4, most of the results can be explained on the basis of intramolecular delivery of the nucleophile to C-3 via a six-membered transition state, leading to 1,4-diols or 1,4-amino alcohol derivatives. In general......, the epoxy alcohols gave poorer regioselectivity than the N-tosyl aziridino alcohols, for which selectivities of >95:5 were routinely obtained. The activating effect of a phenyl group at C-4 led to a switch in regiochemistry, with the 1,3-diol or 1,3-amino alcohol derivative as the major product. (C) 1997...

  5. Interactive effects of ATOH7 and RFTN1 in association with juvenile primary open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    De-Gui Wang

    2017-03-01

    Full Text Available AIM:To study ATOH7 and RFTN1 sequence variations in patients with juvenile primary open-angle glaucoma(JOAG. METHODS: In 298 controls(age≥60yand 52 JOAG(ageATOH7 was sequenced by direct sequencing. Additional single nucleotide polymorphisms the RFTN1 SNP(rs690037and at upstream ATOH7(rs1900004 and rs3858145were genotyped by Taqman assay. RESULTS: No any coding mutation was detected in JOAG. There were no significance in allele frequencies and haplotypes between JOAG and control group of rs7916697, rs61854782, rs1900004、rs3858145 and rs690037, so no SNP was associated with JOAG(P>0.05. CONCLUSION: Although preliminary study has showed combination of ATOH7 and RFTN1 SNPs could increase the risk of getting adult-onset primary open angle glaucoma, ATOH7 and RFTN1 are not associated with juvenile primary open-angle glaucoma in this study, so different types of open-angle glaucoma may be differences in genetic mechanism and be worthy of further study.

  6. Contact angle and surface tension measurements of a five-ring polyphenyl ether

    Science.gov (United States)

    Jones, W. R., Jr.

    1986-01-01

    Contact angle measurements were performed for a five-ring polyphenyl ether isomeric mixture on M-50 steel in a dry nitrogen atmosphere. Two different techniques were used: (1) a tilting plate apparatus, and (2) a sessile drop apparatus. Measurements were made for the temperature range 25 to 190 C. Surface tension was measured by a differential maximum bubble pressure technique over the range 23 to 220 C in room air. The critical surface energy of spreading (gamma /sub c/) was determined for the polyphenyl ether by plotting the cosine of the contact angle (theta) versus the surface tension (gamma /sub LV/). The straight line intercept at cosine theta = 1 is defined as gamma (sub c). Gamma (sub c) was found to be 30.1 dyn/cm for the tilting plate technique and 31.3 dyn/cm for the sessile drop technique. These results indicate that the polyphenyl ether is inherently autophobic (i.e., it will not spread on its own surface film until its surface tension is less than gamma /sub c/). This phenomenon is discussed in light of the wettability and wear problems encountered with this fluid.

  7. [Basic and clinical studies of pressure-independent damaging factors of open angle glaucoma].

    Science.gov (United States)

    Araie, Makoto

    2011-03-01

    Pathogenesis of open-angle glaucoma involves both pressure-dependent damaging factors and pressure-independent damaging factors. The high prevalence of open-angle glaucoma with normal pressure (normal-tension glaucoma) in Japan implies that treatment of pressure-independent damaging factors in Japanese open-angle glaucoma patients is of importance. In an attempt to investigate the roles of pressure-independent damaging factors in open-angle glaucoma, we carried out basic and clinical studies and obtained the following results. 1. The rate of deterioration of visual field after trabeculectomy in normal tension glaucoma patients with post-operative intraocular pressure (IOP) of 10 mmHg was found to be -0.25 dB/year of mean deviation (MD), suggesting that contribution of pressure-independent damaging factors to the deterioration of MD in open-angle glaucoma is around -0.25 dB/year of mean deviation (MD). 2. Experiments using isolated purified cultured retinal ganglion cells (RGCs) indicated that calcium-channel blockers and some of antiglaucoma drugs showed neuroprotective effects on RGCs at concentrations of 0.01 microM or higher. 3. In mice, damage to RGCs resulted in secondary degeneration of neurons and activation of glial cells in the lateral geniculate nucleous (LGN) and superior colliculus, and these secondary changes in the central nervous system (CNS) due to RGC damage was partly ameliorated by systemic administration of memantine. 4. Mice experimental high IOP glaucoma models could be established using laser irradiation of the limbal area, and the usefulness of Tonolab in IOP measurements of mice eye was confirmed. 5. Monkey experimental high IOP glaucoma models revealed that in the glaucomatous optic nerve head vaso-constrictive reactions to an alpha-1 agonist was abolished, while vasodilative reaction to a prostaglandin FP receptor agonist was retained. 6. In monkeys with experimental high IOP glaucoma, secondary damage to neurons in the LGN and the glial

  8. Ocular surface disease incidence in patients with open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    Radenković Marija

    2016-01-01

    Full Text Available Introduction. Ocular surface disease (OSD is a multifactorial disease of the tears and ocular surface that results in symptoms of discomfort, visual disturbances, tear film instability with potential damage to the ocular surface, accompanied by increased tear film osmolarity and inflammation of the ocular surface. It is a consequence of disrupted homeostasis of lacrimal functional unit. The main pathogenetic mechanism stems from tear hyperosmolarity and tear film instability. The etiological classification is hyposecretory (Sy-Sjögren and non-Sjögren and evaporative (extrinsic and intrinsic form. Delphi panel classification grades disease stages. Antiglaucoma topical therapy causes exacerbation or occurrence of symptoms of dry eye due to main ingredients or preservatives (benzalkonium chloride - BAK, which are dose- and time-dependent. BAK reduces the stability of the lipid layer of tears, the number of goblet cells, induces apoptosis and inflammatory infiltration. Objective. The aim of this study was the analysis of the OSD incidence in open-angle glaucoma patients caused by topical medicamentous therapy. Methods. Retrospective analysis of examined patients with open-angle glaucoma was used. Results. Increased incidence of moderate and advanced OSD Index degrees in the group of primary open-angle glaucoma (POAG and pseudoexfoliative glaucoma. According to the Delphi Panel Scale the most common grade is IIb (POAG and pseudoexfoliative glaucoma. Evaporative form of OSD prevailed in all treatment groups. High percentage of dry eye in patients with higher concentrations of preservatives applied was noticed. Conclusion. OSD should be timely diagnosed and treated. Dry eye has an impact on surgical outcome and postoperative visual acuity, and in order to improve patient compliance and quality of life, symptoms of dry eye should be addressed and medications with lower concentrations of preservatives should be applied.

  9. Ocular surface disease incidence in patients with open-angle glaucoma.

    Science.gov (United States)

    Radenković, Marija; Stanković-Babić, Gordana; Jovanović, Predrag; Djordjević-Jocić, Jasmina; Trenkić-Božinović, Marija

    2016-01-01

    Ocular surface disease (OSD) is a multifactorial disease of the tears and ocular surface that results in symptoms of discomfort, visual disturbances, tear film instability with potential damage to the ocular surface, accompanied by increased tear film osmolarity and inflammation of the ocular surface. It is a consequence of disrupted homeostasis of lacrimal functional unit. The main pathogenetic mechanism stems from tear hyperosmolarity and tear film instability. The etiological classification is hyposecretory (Sy-Sjögren and non-Sjögren) and evaporative (extrinsic and intrinsic) form. Delphi panel classification grades disease stages. Antiglaucoma topical therapy causes exacerbation or occurrence of symptoms of dry eye due to main ingredients or preservatives (benzalkonium chloride – BAK), which are dose- and time-dependent. BAK reduces the stability of the lipid layer of tears, the number of goblet cells, induces apoptosis and inflammatory infiltration. The aim of this study was the analysis of the OSD incidence in open-angle glaucoma patients caused by topical medicamentous therapy. Retrospective analysis of examined patients with open-angle glaucoma was used. Increased incidence of moderate and advanced OSD Index degrees in the group of primary open-angle glaucoma (POAG) and pseudoexfoliative glaucoma. According to the Delphi Panel Scale the most common grade is IIb (POAG and pseudoexfoliative glaucoma). Evaporative form of OSD prevailed in all treatment groups. High percentage of dry eye in patients with higher concentrations of preservatives applied was noticed. OSD should be timely diagnosed and treated. Dry eye has an impact on surgical outcome and postoperative visual acuity, and in order to improve patient compliance and quality of life, symptoms of dry eye should be addressed and medications with lower concentrations of preservatives should be applied.

  10. Predictors of Intraocular Pressure After Phacoemulsification in Primary Open-Angle Glaucoma Eyes with Wide Versus Narrower Angles (An American Ophthalmological Society Thesis).

    Science.gov (United States)

    Lin, Shan C; Masis, Marisse; Porco, Travis C; Pasquale, Louis R

    2017-08-01

    To assess if narrower-angle status and anterior segment optical coherence tomography (AS-OCT) parameters can predict intraocular pressure (IOP) drop in primary open-angle glaucoma (POAG) patients after cataract surgery. This was a prospective case series of consecutive cataract surgery patients with POAG and no peripheral anterior synechiae (PAS) using a standardized postoperative management protocol. Preoperatively, patients underwent gonioscopy and AS-OCT. The same glaucoma medication regimen was resumed by 1 month. Potential predictors of IOP reduction included narrower-angle status by gonioscopy and angle-opening distance (AOD500) as well as other AS-OCT parameters. Mixed-effects regression adjusted for use of both eyes and other potential confounders. We enrolled 66 eyes of 40 glaucoma patients. The IOP reduction at 1 year was 4.2±3 mm Hg (26%, P gonioscopy. By AOD500 classification, the narrower-angle group had 3.4±3 mm Hg (21%, P <.001) reduction vs 2.5±3 mm Hg (16%, P <.001) in the wide-angle group ( P =.031 for difference). When the entire cohort was assessed, iris thickness, iris area, and lens vault were correlated with increasing IOP reduction at 1 year ( P <.05 for all). In POAG eyes, cataract surgery lowered IOP to a greater degree in the narrower-angle group than in the wide-angle group, and parameters relating to iris thickness and area, as well as lens vault, were correlated with IOP reduction. These findings can guide ophthalmologists in their selection of cataract surgery as a potential management option.

  11. Functionalization of multi-walled carbon nanotubes by epoxide ring-opening polymerization

    International Nuclear Information System (INIS)

    Jin Fanlong; Rhee, Kyong Yop; Park, Soo-Jin

    2011-01-01

    In this study, covalent functionalization of carbon nanotubes (CNTs) was accomplished by surface-initiated epoxide ring-opening polymerization. FT-IR spectra showed that polyether and epoxide group covalently attached to the sidewalls of CNTs. TGA results indicated that the polyether was successfully grown from the CNT surface, with the final products having a polymer weight percentage of ca. 14–74 wt%. The O/C ratio of CNTs increased significantly from 5.1% to 29.8% after surface functionalization of CNTs. SEM and TEM images of functionalized CNTs exhibited that the tubes were enwrapped by polymer chains with thickness of several nanometers, forming core–shell structures with CNTs at the center. - Graphical abstract: Functionalized CNTs were enwrapped by polymer chains with thickness of several nanometers, forming core–shell structures with CNTs at the center. Highlights: ► CNTs were functionalized by epoxide ring-opening polymerization. ► Polyether and epoxide group covalently attached to the sidewalls of CNTs. ► Functionalized CNTs have a polymer weight percentage of ca. 14–74 wt%. ► Functionalized CNTs were enwrapped by polymer chains with thickness of several nanometers.

  12. Peripheral laser iridoplasty opens angle in plateau iris by thinning the cross-sectional tissues

    Directory of Open Access Journals (Sweden)

    Liu J

    2013-09-01

    Full Text Available Ji Liu,1,2 Tania Lamba,1 David A Belyea1 1Department of Ophthalmology, The George Washington University, Washington DC, USA; 2Yale Eye Center, Yale University, New Haven, CT, USA Abstract: Plateau iris syndrome has been described as persistent angle narrowing or occlusion with intraocular pressure elevation after peripheral iridotomy due to the abnormal plateau iris configuration. Argon laser peripheral iridoplasty (ALPI is an effective adjunct procedure to treat plateau iris syndrome. Classic theory suggests that the laser causes the contraction of the far peripheral iris stroma, "pulls" the iris away from the angle, and relieves the iris-angle apposition. We report a case of plateau iris syndrome that was successfully treated with ALPI. Spectral domain optical coherence tomography confirmed the angle was open at areas with laser treatment but remained appositionally closed at untreated areas. Further analysis suggested significant cross-sectional thinning of the iris at laser-treated areas in comparison with untreated areas. The findings indicate that APLI opens the angle, not only by contracting the iris stroma, but also by thinning the iris tissue at the crowded angle. This is consistent with the ALPI technique to aim at the iris as far peripheral as possible. This case also suggests that spectral domain optical coherence tomography is a useful adjunct imaging tool to gonioscopy in assessing the angle condition. Keywords: plateau iris, optic coherence tomography, argon laser peripheral iridoplasty, angle-closure glaucoma

  13. PRIMARY OPEN-ANGLE GLAUCOMA IN ONCOLOGIC PATIENTS

    Directory of Open Access Journals (Sweden)

    A. A. Ryabtseva

    2015-01-01

    Full Text Available Background: Glaucoma-induced visual impairment negatively influences quality of life of oncologic patients. Yet, tumor in itself and methods of its treatment may promote glaucoma progression. Aim: To study characteristics and course of primary open-angle glaucoma in oncologic patients. Materials and methods: We analyzed case reports of 19 oncologic patients after primary open-angle glaucoma-related sinus trabeculectomy (34 eyes and laser cyclopexy (1 eye. Diagnosed malignancies included colorectal cancer in 5 patients, uterine body and cervical cancer in 4 patients, chronic lymphocytic leukemia in 1 patient, renal cell carcinoma in 1 patient, adrenal cancer in 1 patient, prostatic cancer in 1 patient, breast cancer in 1 patient, vulvar cancer in 1 patient, tongue root cancer in 1 patient. Antiglaucomatous surgery was accomplished during the first 5 years from the diagnosis of tumor in 14 patients. In 9 patients, chemotherapy or hormone therapy was continued by the time of surgery. Follow-up of the patients was undertaken in 4–12 months after the antiglaucomatous operation; it included routine ophthalmological examination and dry eye syndrome functional tests. Results: Duration of postoperative period was 4 months or more. All patients had uveitis postoperatively. During late postoperative period, choroidal detachment was diagnosed in 4 patients. Bleb scarring was found in 2 patients. All patients received hypotensive treatment postoperatively including selective and non-selective beta-adrenergic blockers. Conjunctival and corneal xerosis was observed in all patients. Conclusion: In oncologic patients undergoing antiglaucomatous surgery, long-term (4 months or more postoperative anti-inflammatory therapy is needed along with monthly ophthalmological follow-up during the first year after the operation. In patients with ongoing cytostatic drug treatment, artificial tear should be administrated.

  14. Is open-angle glaucoma associated with early menopause? The Rotterdam Study

    NARCIS (Netherlands)

    Hulsman, C. A.; Westendorp, I. C.; Ramrattan, R. S.; Wolfs, R. C.; Witteman, J. C.; Vingerling, J. R.; Hofman, A.; de Jong, P. T.

    2001-01-01

    The authors examined the association between age at menopause and open-angle glaucoma among women aged > or = 55 years in the population-based Rotterdam Study (1990--1993). Information on age and type of menopause was obtained by interview. Subjects (n = 3,078) were stratified into three categories

  15. Common Genetic Determinants of Intraocular Pressure and Primary Open-Angle Glaucoma

    NARCIS (Netherlands)

    van Koolwijk, Leonieke M. E.; Ramdas, Wishal D.; Ikram, M. Kamran; Jansonius, Nomdo M.; Pasutto, Francesca; Hysi, Pirro G.; Macgregor, Stuart; Janssen, Sarah F.; Hewitt, Alex W.; Viswanathan, Ananth C.; ten Brink, Jacoline B.; Hosseini, S. Mohsen; Amin, Najaf; Despriet, Dominiek D. G.; Willemse-Assink, Jacqueline J. M.; Kramer, Rogier; Rivadeneira, Fernando; Struchalin, Maksim; Aulchenko, Yurii S.; Weisschuh, Nicole; Zenkel, Matthias; Mardin, Christian Y.; Gramer, Eugen; Welge-Luessen, Ulrich; Montgomery, Grant W.; Carbonaro, Francis; Young, Terri L.; Bellenguez, Celine; McGuffin, Peter; Foster, Paul J.; Topouzis, Fotis; Mitchell, Paul; Wang, Jie Jin; Wong, Tien Y.; Czudowska, Monika A.; Hofman, Albert; Uitterlinden, Andre G.; Wolfs, Roger C. W.; de Jong, Paulus T. V. M.; Oostra, Ben A.; Paterson, Andrew D.; Mackey, David A.; Bergen, Arthur A. B.; Reis, Andre; Hammond, Christopher J.; Vingerling, Johannes R.; Lemij, Hans G.; Klaver, Caroline C. W.; van Duijn, Cornelia M.

    2012-01-01

    Intraocular pressure (IOP) is a highly heritable risk factor for primary open-angle glaucoma and is the only target for current glaucoma therapy. The genetic factors which determine IOP are largely unknown. We performed a genome-wide association study for IOP in 11,972 participants from 4

  16. The Influence of Structure Heights and Opening Angles of Micro- and Nanocones on the Macroscopic Surface Wetting Properties

    DEFF Research Database (Denmark)

    Sun, Ling; Laustsen, Milan; Mandsberg, Nikolaj

    2016-01-01

    We discuss the influence of surface structure, namely the height and opening angles of nano-and microcones on the surface wettability. We show experimental evidence that the opening angle of the cones is the critical parameter on sample superhydrophobicity, namely static contact angles and roll......-off angles. The textured surfaces are fabricated on silicon wafers by using a simple one-step method of reactive ion etching at different processing time and gas flow rates. By using hydrophobic coating or hydrophilic surface treatment, we are able to switch the surface wettability from superhydrophilic...

  17. Microwave-assisted cationic ring-opening polymerization of a soy-based 2-oxazoline monomer

    NARCIS (Netherlands)

    Hoogenboom, R.; Wiesbrock, F.D.; Schubert, U.S.

    2005-01-01

    The microwave-assisted cationic ring-opening polymn. of a soy based 2-oxazoline monomer (SoyOx) is described. The microwave irradn. provides more efficient heating when compared to conventional heating and, in addn., the SoyOx was prepd. starting from a sustainable resource (soy beans). The

  18. Vortex ring formation at the open end of a shock tube: A particle image velocimetry study

    Science.gov (United States)

    Arakeri, J. H.; Das, D.; Krothapalli, A.; Lourenco, L.

    2004-04-01

    The vortex ring generated subsequent to the diffraction of a shock wave from the open end of a shock tube is studied using particle image velocimetry. We examine the early evolution of the compressible vortex ring for three-exit shock Mach numbers, 1.1, 1.2, and 1.3. For the three cases studied, the ring formation is complete at about tUb/D=2, where t is time, Ub is fluid velocity behind shock as it exits the tube and D is tube diameter. Unlike in the case of piston generated incompressible vortex rings where the piston velocity variation with time is usually trapezoidal, in the shock-generated vortex ring case the exit fluid velocity doubles from its initial value Ub before it slowly decays to zero. At the end of the ring formation, its translation speed is observed to be about 0.7 Ub. During initial formation and propagation, a jet-like flow exists behind the vortex ring. The vortex ring detachment from the tailing jet, commonly referred to as pinch-off, is briefly discussed.

  19. Phosphazene-promoted metal-free ring-opening polymerization of ethylene oxide initiated by carboxylic acid

    KAUST Repository

    Zhao, Junpeng; Pahovnik, David; Gnanou, Yves; Hadjichristidis, Nikolaos

    2014-01-01

    The effectiveness of carboxylic acid as initiator for the anionic ring-opening polymerization of ethylene oxide was investigated with a strong phosphazene base (t-BuP4) used as promoter. Kinetic study showed an induction period, i.e., transformation

  20. Primary open-angle glaucoma: everyone’s business

    Directory of Open Access Journals (Sweden)

    Hannah Faal

    2012-01-01

    Full Text Available Primary open-angle glaucoma (POAG is sometimes called the ‘thief of sight’. There is no pain or discomfort, and vision loss is so gradual that people often do not notice it.POAG cannot be cured: it requires ongoing treatment for the remainder of a patient’s life. Blindness from POAG also cannot be reversed, but it can be prevented if the disease is diagnosed early and treated. Effectively addressing POAG therefore requires the careful involvement of many different people, including health workers, the patient, non-clinical staff, and health planners.As eye care practitioners, we must do more than merely diagnose and treat people with POAG; we must gain the trust of patients and show them that we are there to help.

  1. Ring-Opening of Oxiranes using Taeniolite-Supported Tris(β-DiketonatoZirconium

    Directory of Open Access Journals (Sweden)

    Yessi Permana

    2012-11-01

    Full Text Available A series of tris(β-diketonatozirconium(IV complexes were immobilized into a synthetic clay structure of Taeniolite by an ion-exchange method to generate organic/inorganic hybrid compounds. The hybrid compound served as a good catalyst for ring-opening reactions of methyl, ethyl, and dimethyl oxiranes with various alcohols to generate primary alkoxy alcohols in appreciable selectivity. This method described a technique to immobilize cationic zirconium complexes without losing selectivity.

  2. TDDFT-MD Study on Dynamics in Photoinduced Ring Opening of Benzene

    Science.gov (United States)

    Tateyama, Yoshitaka; Miyamoto, Yoshiyuki; Oyama, Norihisa; Ohno, Takahisa

    2004-03-01

    Coupled dynamics of ions and electrons in the excited states of molecular and solid benzene is investigated on the femtosecond scale by the efficient simulation scheme recently developed for the time-dependent density functional theory. Within the π arrow π excitations, any out-of-plane motion of ions is not induced in the molecular system basically. In the solid, however, we found that large swing of the C-H bonds and subsequent twist of the carbon ring takes place, leading to sp^3-like bonding of carbon ions. This swing-to-twist motion presents a plausible mechanism underlying the photoinduced ring opening in solid benzene experimentally observed under pressure. This research is partially supported by ACT-JST, and also by FSIS and Special Coordination Funds of Ministry of Education, Culture, Sports, Science and Technology of Japanese Government.

  3. Edge contact angle and modified Kelvin equation for condensation in open pores.

    Science.gov (United States)

    Malijevský, Alexandr; Parry, Andrew O; Pospíšil, Martin

    2017-08-01

    We consider capillary condensation transitions occurring in open slits of width L and finite height H immersed in a reservoir of vapor. In this case the pressure at which condensation occurs is closer to saturation compared to that occurring in an infinite slit (H=∞) due to the presence of two menisci that are pinned near the open ends. Using macroscopic arguments, we derive a modified Kelvin equation for the pressure p_{cc}(L;H) at which condensation occurs and show that the two menisci are characterized by an edge contact angle θ_{e} that is always larger than the equilibrium contact angle θ, only equal to it in the limit of macroscopic H. For walls that are completely wet (θ=0) the edge contact angle depends only on the aspect ratio of the capillary and is well described by θ_{e}≈sqrt[πL/2H] for large H. Similar results apply for condensation in cylindrical pores of finite length. We test these predictions against numerical results obtained using a microscopic density-functional model where the presence of an edge contact angle characterizing the shape of the menisci is clearly visible from the density profiles. Below the wetting temperature T_{w} we find very good agreement for slit pores of widths of just a few tens of molecular diameters, while above T_{w} the modified Kelvin equation only becomes accurate for much larger systems.

  4. Edge contact angle and modified Kelvin equation for condensation in open pores

    Science.gov (United States)

    Malijevský, Alexandr; Parry, Andrew O.; Pospíšil, Martin

    2017-08-01

    We consider capillary condensation transitions occurring in open slits of width L and finite height H immersed in a reservoir of vapor. In this case the pressure at which condensation occurs is closer to saturation compared to that occurring in an infinite slit (H =∞ ) due to the presence of two menisci that are pinned near the open ends. Using macroscopic arguments, we derive a modified Kelvin equation for the pressure pc c(L ;H ) at which condensation occurs and show that the two menisci are characterized by an edge contact angle θe that is always larger than the equilibrium contact angle θ , only equal to it in the limit of macroscopic H . For walls that are completely wet (θ =0 ) the edge contact angle depends only on the aspect ratio of the capillary and is well described by θe≈√{π L /2 H } for large H . Similar results apply for condensation in cylindrical pores of finite length. We test these predictions against numerical results obtained using a microscopic density-functional model where the presence of an edge contact angle characterizing the shape of the menisci is clearly visible from the density profiles. Below the wetting temperature Tw we find very good agreement for slit pores of widths of just a few tens of molecular diameters, while above Tw the modified Kelvin equation only becomes accurate for much larger systems.

  5. Ring opening of azetidine cycle: First examples of 1-azetidinepropanamine molecules as a template in hybrid organic-inorganic compounds

    Science.gov (United States)

    Gurzhiy, Vladislav V.; Tyumentseva, Olga S.; Britvin, Sergey N.; Krivovichev, Sergey V.; Tananaev, Ivan G.

    2018-01-01

    Three novel uranyl selenate and sulfate oxysalts templated by protonated azetidine molecules, [AzH]+, and its ring-opened counterpart 1-azetidinepropanamine, [AzH(CH2)3NH3]2+, have been prepared and studied by X-ray structural analysis. Conformations of azetidinium cations were analysed by means of infrared vibrational assignments supported by the DFT calculations. Crystallization of [AzH]2 [(UO2)2(SeO4)3(H2O)] (I) from highly acidic solutions suggests that low pH does not necessarily result in the opening of azetidine ring. [AzH(CH2)3NH3][(UO2)2(SeO4)3(H2O)](H2O) (II) and [AzH(CH2)3NH3](H5O2)[(UO2)2(SO4)3(HSO4)] (III) are the first structurally characterized crystalline compounds bearing isolated ring-opened azetidine moiety.

  6. Comparative Theoretical Study of the Ring-Opening Polymerization of Caprolactam vs Caprolactone Using QM/MM Methods

    Energy Technology Data Exchange (ETDEWEB)

    Elsasser, Brigitta M.; Schoenen, Iris; Fels, Gregor

    2013-06-07

    Candida antarctica lipase B (CALB) efficiently catalyzes the ring-opening polymerization of lactones to high molecular weight products in good yield. In contrast, an efficient enzymatic synthesis of polyamides has so far not been described in the literature. This obvious difference in enzyme catalysis is the subject of our comparative study of the initial steps of a CALB catalyzed ring-opening polymerization of ε- caprolactone and ε-caprolactam. We have applied docking tools to generate the reactant state complex and performed quantum mechanical/molecular mechanical (QM/MM) calculations at the density functional theory (DFT) PBE0 level of theory to simulate the acylation of Ser105 by the lactone and the lactam, respectively, via the corresponding first tetrahedral intermediates. We could identify a decisive difference in the accessibility of the two substrates in the ring-opening to the respective acyl enzyme complex as the attack of ε-caprolactam is hindered because of an energetically disfavored proton transfer during this part of the catalytic reaction while ε-caprolactone is perfectly processed along the widely accepted pathway using the catalytic triade of Ser105, His224, and Asp187. Since the generation of an acylated Ser105 species is the crucial step of the polymerization procedure, our results give an explanation for the unsatisfactory enzymatic polyamide formation and opens up new possibilities for targeted rational catalyst redesign in hope of an experimentally useful CALB catalyzed polyamide synthesis.

  7. Persistent Corneal Decompensation due to Anterior Dislocation of Soemmering Ring Cataract

    Directory of Open Access Journals (Sweden)

    Travis Peck

    2017-01-01

    Full Text Available Purpose. We present a case of a patient with Soemmering ring after cataract surgery and a potential complication that can arise as a result of its presence. Observations. A patient with history of ruptured globe status after repair and lensectomy, complicated by aphakic secondary open angle glaucoma, was referred for management of second injury to the same eye. This injury resulted in Soemmering ring dislocation into the anterior chamber. The cortical material caused a significant increase in intraocular pressure and corneal decompensation. Surgical removal of the Soemmering ring and Ahmed glaucoma tube implant was performed with control of intraocular pressures; however corneal edema could not be reversed. Conclusions and Importance. This case report illustrates the serious consequences that can be caused by Soemmering rings without early surgical intervention. Care must be taken to completely remove cortical material during cataract surgery to prevent their formation.

  8. Blindness following bleb-related infection in open angle glaucoma.

    Science.gov (United States)

    Yamada, Hiroki; Sawada, Akira; Kuwayama, Yasuaki; Yamamoto, Tetsuya

    2014-11-01

    To estimate the risk of blindness following bleb-related infection after trabeculectomy with mitomycin C in open angle glaucoma, utilizing data obtained from two prospective multicenter studies. The incidence of bleb-related infection in open angle glaucoma after the first or second glaucoma surgery was calculated using a Kaplan-Meier analysis and data from the Collaborative Bleb-related Infection Incidence and Treatment Study (CBIITS). The rate of blindness following bleb-related infection was calculated using data from the Japan Glaucoma Society Survey of Bleb-related Infection (JGSSBI). Finally, the rate of blindness following bleb-related infection after filtering surgery was estimated based on the above two data sets. Blindness was defined as an eye with a visual acuity of 0.04 or less. The incidences of development of bleb-related infection at 5 years were 2.6 ± 0.7 % (calculated cumulative incidence ± standard error) for all infections and 0.9 ± 0.4 % for endophthalmitis in all cases in the CBIITS data. The rates of blindness in the JGSSBI data were 14 % for the total cases with bleb-related infection and 30 % for the endophthalmitis subgroup. The rate of blindness developing within 5 years following trabeculectomy was estimated to be approximately 0.24-0.36 %. The rate of blindness following bleb-related infection within 5 years after trabeculectomy is considerable and thus careful consideration must be given to the indication for trabeculectomy and the selection of surgical techniques.

  9. Synthesis of Polysiloxanes In Microemulsion Via ring opening of D4

    Directory of Open Access Journals (Sweden)

    Liu Jiesheng

    2016-07-01

    Full Text Available Polydimethylsiloxane (PDMS has been synthesized by ring-opening polymerization of octamethylcyclotetrasiloxane (D4 in microemulsion with acidic catalyst. The structure and properties of microemulsion were characterized by Transmission Electron Microscopy (TEM, Fourier Transform Infrared Spectroscopy (FT-IR, Photo Correlation Spectroscopy (PCS. The effect of the variation in pH value, amount of catalyst, emulsifier and monomer dropping rate on the properties of microemulsion were investigated and discussed. The results showed that the particle size of the latex becomes smaller, and the distribution size becomes wider with increasing the content of catalyst and emulsifier. When pH value changed, the reaction rate of ring-opening of D4 was faster with strong acid than that under the weak acid condition. The emulsification of 2 % OP-10 (Alkylphenol polyoxyethylene ether and 3.0% DBSA (Dodecyl benzenesulfonic acid reached to equilibrium in microemulsion. As the amount of OP-10 increases, the size of particles lowered and their corresponding  distribution widened. It is observed that emulsifier (OP-10 does not affect the transparency of the microemulsion in the case of the application of DBSA. As the monomer dropping time increased, the grain size diminished and the size distribution widened. PCS results showed that the smallest particle size was around 20nm. Taking into account of the stability of the microemulsions, the dropping time of the monomer was around 30 min.

  10. Photophysical property of rhodamine-cored poly(amidoamine) dendrimers: Simultaneous effect of spirolactam ring-opening and PET process on sensing trivalent chromium ion

    International Nuclear Information System (INIS)

    Lei Yonglin; Su Yuanqiang; Huo Jichuan

    2011-01-01

    Two novel poly(amidoamine) (PAMAM) dendrimers, comprising rhodamine B unit in the core and 1-phenyl-3-methyl-5-pyrazolone unit at the periphery, have been synthesized and characterized. Both dendrimers displayed high selectivity and sensitivity towards Cr 3+ ion. As considering the potential of being applied as fluorescent sensors for Cr 3+ ion, we studied the complexes formed between the dendrimers and Cr 3+ ion. Different PAMAM dendrimers had different recognition mechanism towards Cr 3+ ion. For dendrimer G2, the recognition of Cr 3+ was mainly due to the ring-opening of spirolactam. However, it significantly depended on the simultaneous effect of ring-opening of spirolactam and photoinduced electron transfer (PET) in the case of dendrimer G3. - Highlights: → First synthesize two novel PAMAM simultaneously containing rhodamine and pyrazolone. → Novel dendrimer show high selectivity and sensitivity towards Cr 3+ . → Recognition Cr 3+ of dendrimer G2 is dominantly due to the ring-opening mechanism. → Sensing Cr 3+ of dendrimer G3 is dependent on simultaneous mechanisms of ring-opening and PET.

  11. Ring-opening of cyclic ethers with carbon–carbon bond formation by Grignard reagents

    DEFF Research Database (Denmark)

    Christensen, Stig Holden; Holm, Torkil; Madsen, Robert

    2014-01-01

    The ring-opening of cyclic ethers with concomitant C–C bond formation was studied with a number of Grignard reagents. The transformation was performed in a sealed vial by heating to ∼160 °C in an aluminum block or at 180 °C in a microwave oven. Good yields of the product alcohols were obtained...

  12. Changes in the Lipidomic Profile of Aqueous Humor in Open-Angle Glaucoma

    DEFF Research Database (Denmark)

    Cabrerizo, Javier; Urcola, Javier A; Vecino, Elena

    2017-01-01

    PURPOSE: To identify and determine differences in lipid profiles of aqueous humor (AH) in patients with open-angle glaucoma (OAG). MATERIALS AND METHODS: The lipidomic profile of 10 samples of AH of patients with OAG and 10 controls was analyzed. Patients with a history of anterior segment surgery...

  13. Lipase-catalyzed ring-opening polymerization of lactones to polyesters and its mechanistic aspects.

    Science.gov (United States)

    Namekawa, S; Suda, S; Uyama, H; Kobayashi, S

    1999-01-01

    Lipase catalysis induced a ring-opening polymerization of lactones with different ring-sizes. Small-size (four-membered) and medium-size lactones (six- and seven-membered) as well as macrolides (12-, 13-, 16-, and 17-membered) were subjected to lipase-catalyzed polymerization. The polymerization behaviors depended primarily on the lipase origin and the monomer structure. The macrolides showing much lower anionic polymerizability were enzymatically polymerized faster than epsilon-caprolactone. The granular immobilized lipase derived from Candida antartica showed extremely efficient catalysis in the polymerization of epsilon-caprolactone. Single-step terminal functionalization of the polyester was achieved by initiator and terminator methods. The enzymatic polymerizability of lactones was quantitatively evaluated by Michaelis-Menten kinetics.

  14. New insights into the by-product fatigue mechanism of the photo-induced ring-opening in diarylethenes.

    Science.gov (United States)

    Mendive-Tapia, David; Perrier, Aurélie; Bearpark, Michael J; Robb, Michael A; Lasorne, Benjamin; Jacquemin, Denis

    2014-09-14

    The photochromic properties of diarylethenes, some of the most studied class of molecular switches, are known to be controlled by non-adiabatic decay at a conical intersection seam. Nevertheless, as their fatigue-reaction mechanism - leading to non-photochromic products - is yet to be understood, we investigate the photo-chemical formation of the so-called by-product isomer using three complementary computational methods (MMVB, CASSCF and CASPT2) on three model systems of increasing complexity. We show that for the ring-opening reaction a transition state on S1(2A) involving bond breaking of the penta-ring leads to a low energy S1(2A)/S0(1A) conical intersection seam, which lies above one of the transition states leading to the by-product isomer on the ground state. Therefore, radiationless decay and subsequent side-product formation can take place explaining the photo-degradation responsible for the by-product generation in diarylethene-type molecules. The effect of dynamic electron correlation and the possible role of inter-system crossing along the penta-ring opening coordinate are discussed as well.

  15. Levels of aqueous humor trace elements in patients with open-angle glaucoma.

    Science.gov (United States)

    Hohberger, Bettina; Chaudhri, M Anwar; Michalke, Bernhard; Lucio, Marianna; Nowomiejska, Katarzyna; Schlötzer-Schrehardt, Ursula; Grieb, Pawel; Rejdak, Robert; Jünemann, Anselm G M

    2018-01-01

    Trace elements might play a role in the complex multifactorial pathogenesis of open-angle glaucoma. The aim of this study was to analyze concentrations of trace elements in aqueous humor samples of patients with primary open-angle glaucoma (POAG) and pseudoexfoliation glaucoma (PEXG). Thirty-three aqueous humor samples were obtained from patients undergoing cataract surgery: 12 patients with POAG (age 65.3±10.50, female 8, male 4), 10 patients with PEXG (age 65.9±11.27, female 6, male 4) and 11 patients without glaucoma (age 69.5±13.70, female 7, male 4) serving as controls. Aqueous humor levels of cadmium, iron, manganese, cobalt, copper and zinc were measured by Flow-Injection-Inductively-Coupled-Plasma-Mass-Spectrometry (FI-ICP-MS). From the statistical evaluation, we observed that patients with POAG had significantly higher aqueous humor levels of zinc (p=0.006) compared to controls. Increased aqueous humor levels of zinc were also observed in patients with PEXG in relation to control (p=0.0006). For iron we observed a significantly reduction in PEXG compared to control (p=0.002) and a significant difference between POAG and PEXG (p=0.0091). No significant differences were observed in aqueous humor levels of manganese, cobalt, copper, cadmium between glaucoma and control patients. No differences were seen for iron (POAG vs. controls). Analysis of trace element ratios was added. Significant differences in aqueous humor levels of zinc and iron between glaucoma and control patients support the hypothesis that these trace elements are involved in the pathogenesis of open-angle glaucoma. Copyright © 2017 Elsevier GmbH. All rights reserved.

  16. Ring closure in actin polymers

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, Supurna, E-mail: supurna@rri.res.in [Raman Research Institute, Bangalore 560080 (India); Chattopadhyay, Sebanti [Doon University, Dehradun 248001 (India)

    2017-03-18

    We present an analysis for the ring closure probability of semiflexible polymers within the pure bend Worm Like Chain (WLC) model. The ring closure probability predicted from our analysis can be tested against fluorescent actin cyclization experiments. We also discuss the effect of ring closure on bend angle fluctuations in actin polymers. - Highlights: • Ring closure of biopolymers. • Worm like chain model. • Predictions for experiments.

  17. Study of improvement in 1st ring`s gas-seal; Top ring no gas seal seino kojo no kento

    Energy Technology Data Exchange (ETDEWEB)

    Ando, H; Tateishi, Y; Fujimura, K; Hitosugi, H [Nippon Piston Ring Co. Ltd., Tokyo (Japan)

    1997-10-01

    The authors studied the effect of an angle of 1st ring twist on the amount of blow-by concerning higher speed/higher output engines for motorcycles. As a result, the authors found the twist made the ring restrained in a ring groove of piston , and confirmed its suitable range for blow-by. By means of the developed optimization method, the authors have achieved significant reduction in blow-by at high engine speed. 1 ref., 9 figs., 2 tabs.

  18. Large-angle cosmic microwave background anisotropies in an open universe

    Science.gov (United States)

    Kamionkowski, Marc; Spergel, David N.

    1994-01-01

    If the universe is open, scales larger than the curvature scale may be probed by observation of large-angle fluctuations in the cosmic microwave background (CMB). We consider primordial adiabatic perturbations and discuss power spectra that are power laws in volume, wavelength, and eigenvalue of the Laplace operator. Such spectra may have arisen if, for example, the universe underwent a period of `frustated' inflation. The resulting large-angle anisotropies of the CMB are computed. The amplitude generally increases as Omega is decreased but decreases as h is increased. Interestingly enough, for all three Ansaetze, anisotropies on angular scales larger than the curvature scale are suppressed relative to the anisotropies on scales smaller than the curvature scale, but cosmic variance makes discrimination between various models difficult. Models with 0.2 approximately less than Omega h approximately less than 0.3 appear compatible with CMB fluctuations detected by Cosmic Background Explorer Satellite (COBE) and the Tenerife experiment and with the amplitude and spectrum of fluctuations of galaxy counts in the APM, CfA, and 1.2 Jy IRAS surveys. COBE normalization for these models yields sigma(sub 8) approximately = 0.5 - 0.7. Models with smaller values of Omega h when normalized to COBE require bias factors in excess of 2 to be compatible with the observed galaxy counts on the 8/h Mpc scale. Requiring that the age of the universe exceed 10 Gyr implies that Omega approximately greater than 0.25, while requiring that from the last-scattering term in the Sachs-Wolfe formula, large-angle anisotropies come primarily from the decay of potential fluctuations at z approximately less than 1/Omega. Thus, if the universe is open, COBE has been detecting temperature fluctuations produced at moderate redshift rather than at z approximately 1300.

  19. Radiation pattern of open ended waveguide in air core surrounded by annular plasma column

    International Nuclear Information System (INIS)

    Sharma, D.R.; Verma, J.S.

    1977-01-01

    Radiation pattern of open ended waveguide excited in circular symmetric mode (TM 01 ) in an air core having central conductor and surrounded by an annular plasma column is studied. The field distribution at the open end of the waveguide is considered to be equivalent to the vector sum of magnetic current rings of various radii, ranging from the outer radius of the inner conductor to the inner radius of the outer conductor of the waveguide at the open end. The radiation field is obtained as a vector sum of field components due to individual rings of current. Such a configuration gives rise to multiple narrow radiation beams away from the critical angle. (author)

  20. Palladium-catalyzed ring-opening reactions of cyclopropanated 7-oxabenzonorbornadiene with alcohols

    Directory of Open Access Journals (Sweden)

    Katrina Tait

    2016-10-01

    Full Text Available Palladium-catalyzed ring-opening reactions of cyclopropanated 7-oxabenzonorbornadiene derivatives using alcohol nucleophiles were investigated. The optimal conditions were found to be 10 mol % PdCl2(CH3CN2 in methanol, offering yields up to 92%. The reaction was successful using primary, secondary and tertiary alcohol nucleophiles and was compatible with a variety of substituents on cyclopropanated oxabenzonorbornadiene. With unsymmetrical C1-substituted cyclopropanated 7-oxabenzonorbornadienes, the regioselectivity of the reaction was excellent, forming only one regioisomer in all cases.

  1. The Influence of Structure Heights and Opening Angles of Micro- and Nanocones on the Macroscopic Surface Wetting Properties

    Science.gov (United States)

    Schneider, Ling; Laustsen, Milan; Mandsberg, Nikolaj; Taboryski, Rafael

    2016-01-01

    We discuss the influence of surface structure, namely the height and opening angles of nano- and microcones on the surface wettability. We show experimental evidence that the opening angle of the cones is the critical parameter on sample superhydrophobicity, namely static contact angles and roll-off angles. The textured surfaces are fabricated on silicon wafers by using a simple one-step method of reactive ion etching at different processing time and gas flow rates. By using hydrophobic coating or hydrophilic surface treatment, we are able to switch the surface wettability from superhydrophilic to superhydrophobic without altering surface structures. In addition, we show examples of polymer replicas (polypropylene and poly(methyl methacrylate) with different wettability, fabricated by injection moulding using templates of the silicon cone-structures. PMID:26892169

  2. Ring Opening Metathesis Polymerization of Cyclopentene Using a Ruthenium Catalyst Confined by a Branched Polymer Architecture

    KAUST Repository

    Mugemana, Clement; Bukhriakov, Konstantin; Bertrand, Olivier; Vu, Khanh B.; Gohy, Jean-Francois; Hadjichristidis, Nikolaos; Rodionov, Valentin

    2016-01-01

    Multi-arm polystyrene stars functionalized with Grubbs-type catalysts in their cores were synthesized and used for the ring-opening metathesis polymerization (ROMP) of cyclopentene. The spatial confinement of the catalytic sites and the nanoscale phase separation between polystyrene and the growing polypentenamer chains lead to a dramatic inhibition of the ROMP termination and chain transfer steps. Consequently, cyclopentene polymerizations proceeded fast and with a high degree of conversion even in air. The Grubbs second generation catalyst was oxidatively inactivated under the same conditions. In contrast to conventional small-molecule catalysts, the ultimate degree of conversion of cyclopentene monomer and the polydispersity of the product polypentenamer are not affected by the temperature. This indicates that spatial confinement of the catalyst resulted in a significant change in the activation parameters for the alkene metathesis ring-opening.

  3. Ring Opening Metathesis Polymerization of Cyclopentene Using a Ruthenium Catalyst Confined by a Branched Polymer Architecture

    KAUST Repository

    Mugemana, Clement

    2016-03-22

    Multi-arm polystyrene stars functionalized with Grubbs-type catalysts in their cores were synthesized and used for the ring-opening metathesis polymerization (ROMP) of cyclopentene. The spatial confinement of the catalytic sites and the nanoscale phase separation between polystyrene and the growing polypentenamer chains lead to a dramatic inhibition of the ROMP termination and chain transfer steps. Consequently, cyclopentene polymerizations proceeded fast and with a high degree of conversion even in air. The Grubbs second generation catalyst was oxidatively inactivated under the same conditions. In contrast to conventional small-molecule catalysts, the ultimate degree of conversion of cyclopentene monomer and the polydispersity of the product polypentenamer are not affected by the temperature. This indicates that spatial confinement of the catalyst resulted in a significant change in the activation parameters for the alkene metathesis ring-opening.

  4. Well-defined polyethylene molecular brushes by polyhomologation and ring opening metathesis polymerization

    KAUST Repository

    Zhang, Hefeng; Gnanou, Yves; Hadjichristidis, Nikolaos

    2014-01-01

    A novel strategy using polyhomologation and ring opening metathesis polymerization (ROMP) has been developed for the synthesis of well-defined polyethylene (PE) molecular brushes. Polyhomologation was used to afford an OH-terminated PE, which after transformation to the norbornyl PE macromonomer was subjected to ROMP. Kinetics of ROMP of the PE macromonomer was studied by in situ1H NMR monitoring. The brush structure was proved from HT-GPC, 1H NMR and DSC results.

  5. Effects of the Amount and Type of Diol Ring Openers on the Properties of Oligolactide Acrylates for UV-Curable Printing Inks

    Directory of Open Access Journals (Sweden)

    Santi Kulsiriswad

    2017-10-01

    Full Text Available This study aimed to synthesize low viscosity oligolactide acrylates for UV-curable inks from oligolactide diols. Firstly, low molecular weight oligolactide diols were prepared by ring opening reaction of L-lactide with diols. Oligolactide acrylates were then synthesized by functionalizing the oligolactide diols with acrylic acid. In this study, three diol ring openers having short and long alkyl chain length were used to investigate the effects of the amount and type of diols on the properties of the oligolactide acrylates. The obtained oligomers were characterized, and the viscosities of oligolactide acrylates were measured. Results showed that oligolactide acrylates were successfully synthesized in all cases of ring openers, as confirmed by 1H-NMR (proton nuclear magnetic resonance spectroscopy and FTIR (Fourier transform infrared spectroscopy. An increase in the alkyl chain length of the ring openers resulted in oligomers with lower viscosity and a decrease in Tg. Following that, the obtained oligolactide acrylates were employed for the formulation of UV-curable screen printing inks and their properties were investigated. Results showed that the inks formulated from oligomers with lower molecular weight exhibited better ink flow. Additionally, all ink films cured by UV radiation were very flexible with excellent adhesion, high impact resistance, and excellent water resistance.

  6. Characterizing exo-ring systems around fast-rotating stars using the Rossiter-McLaughlin effect

    Science.gov (United States)

    de Mooij, Ernst J. W.; Watson, Christopher A.; Kenworthy, Matthew A.

    2017-12-01

    Planetary rings produce a distinct shape distortion in transit light curves. However, to accurately model such light curves the observations need to cover the entire transit, especially ingress and egress, as well as an out-of-transit baseline. Such observations can be challenging for long period planets, where the transits may last for over a day. Planetary rings will also impact the shape of absorption lines in the stellar spectrum, as the planet and rings cover different parts of the rotating star (the Rossiter-McLaughlin effect). These line-profile distortions depend on the size, structure, opacity, obliquity and sky-projected angle of the ring system. For slow-rotating stars, this mainly impacts the amplitude of the induced velocity shift; however, for fast-rotating stars the large velocity gradient across the star allows the line distortion to be resolved, enabling direct determination of the ring parameters. We demonstrate that by modelling these distortions we can recover ring system parameters (sky-projected angle, obliquity and size) using only a small part of the transit. Substructure in the rings, e.g. gaps, can be recovered if the width of the features (δW) relative to the size of the star is similar to the intrinsic velocity resolution (set by the width of the local stellar profile, γ) relative to the stellar rotation velocity (v sini, i.e. δW/R* ≳ vsini/γ). This opens up a new way to study the ring systems around planets with long orbital periods, where observations of the full transit, covering the ingress and egress, are not always feasible.

  7. Comparison between visual field defect in pigmentary glaucoma and primary open-angle glaucoma.

    Science.gov (United States)

    Nilforushan, Naveed; Yadgari, Maryam; Jazayeri, Anisalsadat

    2016-10-01

    To compare visual field defect patterns between pigmentary glaucoma and primary open-angle glaucoma. Retrospective, comparative study. Patients with diagnosis of primary open-angle glaucoma (POAG) and pigmentary glaucoma (PG) in mild to moderate stages were enrolled in this study. Each of the 52 point locations in total and pattern deviation plot (excluding 2 points adjacent to blind spot) of 24-2 Humphrey visual field as well as six predetermined sectors were compared using SPSS software version 20. Comparisons between 2 groups were performed with the Student t test for continuous variables and the Chi-square test for categorical variables. Thirty-eight eyes of 24 patients with a mean age of 66.26 ± 11 years (range 48-81 years) in the POAG group and 36 eyes of 22 patients with a mean age of 50.52 ± 11 years (range 36-69 years) in the PG group were studied. (P = 0.00). More deviation was detected in points 1, 3, 4, and 32 in total deviation (P = 0.03, P = 0.015, P = 0.018, P = 0.023) and in points 3, 4, and 32 in pattern deviation (P = 0.015, P = 0.049, P = 0.030) in the POAG group, which are the temporal parts of the field. It seems that the temporal area of the visual field in primary open-angle glaucoma is more susceptible to damage in comparison with pigmentary glaucoma.

  8. [Magnetotherapy designed to affect cervical sympathetic ganglia for the treatment of patients with primary open-angle glaucoma].

    Science.gov (United States)

    Veselova, E V; Kamenskikh, T G; Raĭgorodkiĭ, Iu M; Kolbenev, I O; Myshkina, E S

    2010-01-01

    The traveling magnetic field was used to treat primary open-angle glaucoma. The field was applied to the projection of cervical sympathetic ganglia of the patients. Hemodynamic parameters of posterior short ciliary arteries and central retinal artery were analysed along with visual evoked potentials, visual field limits, and visual acuity. It was shown that magnetotherapy with the use of an AMO-ATOS apparatus produces better clinical results in patients with stage I and II primary open-angle glaucoma compared with medicamentous therapy (intake of trental tablets).

  9. Synthesis of γ-hydroxypropyl P-chirogenic (±-phosphorus oxide derivatives by regioselective ring-opening of oxaphospholane 2-oxide precursors

    Directory of Open Access Journals (Sweden)

    Iris Binyamin

    2015-07-01

    Full Text Available The synthesis of P-chirogenic (±-phosphine oxides and phosphinates via selective nucleophilic ring opening of the corresponding oxaphospholanes is described. Two representative substrates: the phosphonate 2-ethoxy-1,2-oxaphospholane 2-oxide and the phosphinate 2-phenyl-1,2-oxaphospholane 2-oxide were reacted with various Grignard reagents to produce a single alkyl/aryl product. These products may possess further functionalities in addition to the phosphorus center such as the γ-hydroxypropyl group which results from the ring opening and π-donor moieties such as aryl, allyl, propargyl and allene which originates from the Grignard reagent.

  10. Measurement of opening and closing angles of aortic valve prostheses in vivo using dual-source computed tomography: Comparison with those of manufacturers' in 10 different types

    International Nuclear Information System (INIS)

    Suh, Young Joo; Kim, Young Jin; Hong, Yoo Jin; Lee, Hye Jeong; Hur, Jin; Im, Dong Jin; Kim, Yun Jung; Choi, Byoung Wook

    2015-01-01

    The aims of this study were to compare opening and closing angles of normally functioning mechanical aortic valves measured on dual-source computed tomography (CT) with the manufacturers' values and to compare CT-measured opening angles according to valve function. A total of 140 patients with 10 different types of mechanical aortic valves, who underwent dual-source cardiac CT, were included. Opening and closing angles were measured on CT images. Agreement between angles in normally functioning valves and the manufacturer values was assessed using the interclass coefficient and the Bland-Altman method. CT-measured opening angles were compared between normal functioning valves and suspected dysfunctioning valves. The CT-measured opening angles of normally functioning valves and manufacturers' values showed excellent agreement for seven valve types (intraclass coefficient [ICC], 0.977; 95% confidence interval [CI], 0.962-0.987). The mean differences in opening angles between the CT measurements and the manufacturers' values were 1.2° in seven types of valves, 11.0° in On-X valves, and 15.5° in ATS valves. The manufacturers' closing angles and those measured by CT showed excellent agreement for all valve types (ICC, 0.953; 95% CI, 0.920-0.972). Among valves with suspected dysfunction, those with limitation of motion (LOM) and an increased pressure gradient (PG) had smaller opening angles than those with LOM only (p < 0.05). Dual-source cardiac CT accurately measures opening and closing angles in most types of mechanical aortic valves, compared with the manufacturers' values. Opening angles on CT differ according to the type of valve dysfunction and a decreased opening angle may suggest an elevated PG

  11. Variants in the ASB10 Gene Are Associated with Primary Open Angle Glaucoma

    NARCIS (Netherlands)

    Micheal, S.; Ayub, H.; Islam, F.; Siddiqui, S.N.; Khan, W.A.; Akhtar, F.; Qamar, R.; Khan, M.I.; Hollander, A.I. den

    2015-01-01

    BACKGROUND: Recently nonsynonymous coding variants in the ankyrin repeats and suppressor of cytokine signaling box-containing protein 10 (ASB10) gene were found to be associated with primary open angle glaucoma (POAG) in cohorts from Oregon and Germany, but this finding was not confirmed in an

  12. NATO Advanced Study Institute on Ring-opening Metathesis Polymerization of Olefins and Polymerization of Alkynes

    CERN Document Server

    1998-01-01

    The first NATO Advanced Study Institute on Olefin Metathesis and Polymerization Catalysts was held on September 10-22, 1989 in Akcay, Turkey. Based on the fundamental research of RRSchrock, RGrubbs and K.B.Wagener in the field of ring opening metathesis polymerization (ROMP), acyclic diene metathesis (ADMET) and alkyne polymerization, these areas gained growing interest within the last years. Therefore the second NATO-ASI held on metathesis reactions was on Ring Opening Metathesis Po­ lymerization of Olefins and Polymerization of Alkynes on September 3-16, 1995 in Akcay, Turkey. The course joined inorganic, organic and polymer chemists to exchange their knowledge in this field. This volume contains the main and short lectures held in Akcay. To include ADMET reactions better into the title of this volume we changed it into: Metathesis Polymerization of Olefins and Alkyne Polymerization. This volume is addressed to research scientists, but also to those who start to work in the area of olefin metathesis and al...

  13. [New directions in the hypotensive therapy of open-angle glaucoma (experimental and clinical research)].

    Science.gov (United States)

    Bunin, A Ia; Ermakov, V N; Filina, A A

    1993-01-01

    Clinical use of eye drops of a hybrid beta-alpha-adrenoblocker OF-4680 to reduce intraocular pressure has shown a high efficacy of the drug, not inferior to thymolol, for local hypotensive therapy of open-angle glaucoma. A combination of thymolol with taurin helped reduce the inhibiting effect of the beta-blocker on chamber humor secretion and simultaneously enhanced its discharge. The results evidence the desirability of correcting glutathion deficiency, detected in the patients with narrow-angle glaucoma, by lipoic acid.

  14. Evaluation of blotchy pigments in the anterior chamber angle as a sign of angle closure

    Directory of Open Access Journals (Sweden)

    Harsha L Rao

    2012-01-01

    Full Text Available Background: Blotchy pigments in the anterior chamber (AC angle are considered diagnostic of primary angle closure (PAC. But there are no reports either on the prevalence of blotchy pigments in AC angles or the validity of this sign. Aims: To determine the prevalence of blotchy pigments in AC angles and to evaluate their relationship with glaucomatous optic neuropathy (GON in eyes with occludable angles. Setting and Design: Cross-sectional, comparative study. Materials and Methods: Gonioscopy was performed in 1001 eyes of 526 subjects (245 eyes of 148 consecutive, occludable angle subjects and 756 eyes of 378 non-consecutive, open angle subjects, above 35 years of age. Quadrant-wise location of blotchy pigments was documented. Statistical Analysis: Odds of blotchy pigments in occludable angles against that in open angles were evaluated. Relationship of GON with blotchy pigments in occludable angle eyes was evaluated using a multivariate model. Results: Prevalence of blotchy pigments in occludable angles was 28.6% (95% CI, 22.9-34.3 and in open angles was 4.7% (95% CI, 3.2-6.3. Blotchy pigments were more frequently seen in inferior (16% and superior quadrants (15% of occludable angles, and inferior quadrant of open angles (4%. Odds of superior quadrant blotchy pigments in occludable angles were 33 times that in open angles. GON was seen in 107 occludable angle eyes. Blotchy pigments were not significantly associated with GON (odds ratio = 0.5; P = 0.1. Conclusions: Blotchy pigments were seen in 28.6% of occludable angle eyes and 4.7% of open angles eyes. Presence of blotchy pigments in the superior quadrant is more common in occludable angles. Presence of GON in occludable angle eyes was not associated with blotchy pigments.

  15. Evaluation of blotchy pigments in the anterior chamber angle as a sign of angle closure

    Science.gov (United States)

    Rao, Harsha L; Mungale, Sachin C; Kumbar, Tukaram; Parikh, Rajul S; Garudadri, Chandra S

    2012-01-01

    Background: Blotchy pigments in the anterior chamber (AC) angle are considered diagnostic of primary angle closure (PAC). But there are no reports either on the prevalence of blotchy pigments in AC angles or the validity of this sign. Aims: To determine the prevalence of blotchy pigments in AC angles and to evaluate their relationship with glaucomatous optic neuropathy (GON) in eyes with occludable angles. Setting and Design: Cross-sectional, comparative study. Materials and Methods: Gonioscopy was performed in 1001 eyes of 526 subjects (245 eyes of 148 consecutive, occludable angle subjects and 756 eyes of 378 non-consecutive, open angle subjects), above 35 years of age. Quadrant-wise location of blotchy pigments was documented. Statistical Analysis: Odds of blotchy pigments in occludable angles against that in open angles were evaluated. Relationship of GON with blotchy pigments in occludable angle eyes was evaluated using a multivariate model. Results: Prevalence of blotchy pigments in occludable angles was 28.6% (95% CI, 22.9-34.3) and in open angles was 4.7% (95% CI, 3.2-6.3). Blotchy pigments were more frequently seen in inferior (16%) and superior quadrants (15%) of occludable angles, and inferior quadrant of open angles (4%). Odds of superior quadrant blotchy pigments in occludable angles were 33 times that in open angles. GON was seen in 107 occludable angle eyes. Blotchy pigments were not significantly associated with GON (odds ratio = 0.5; P = 0.1). Conclusions: Blotchy pigments were seen in 28.6% of occludable angle eyes and 4.7% of open angles eyes. Presence of blotchy pigments in the superior quadrant is more common in occludable angles. Presence of GON in occludable angle eyes was not associated with blotchy pigments. PMID:23202393

  16. Si-Imidazole-HSO4 Functionalized Magnetic Fe3O4 Nanoparticles as an Efficient and Reusable Catalyst for the Regioselective Ring Opening of Epoxides in Water

    Directory of Open Access Journals (Sweden)

    Eshagh Rezaee Nezhad

    2016-01-01

    Full Text Available An efficient and simple method for the preparation of Si-Imidazole-HSO4 functionalized magnetic Fe3O4 nanoparticles (Si-Im-HSO4 MNPs and used as an efficient and reusable magnetic catalysts for the regioselective ring opening of epoxides under green conditions in water. This catalyst was used for the ring opening of epoxide corresponding to the thiocyanohydrins and azidohydrines. Compared to the classical ring opening of epoxides, this new method consistently has the advantage of excellent yields, short reaction times, and methodological simplicity.

  17. Prevalence of open angle glaucoma in accompanying first degree relatives of patients with glaucoma

    Directory of Open Access Journals (Sweden)

    Franciele Vegini

    2008-01-01

    Full Text Available OBJECTIVE: The aim of this study was to determine the prevalence of open angle glaucoma in first-degree relatives accompanying POAG patients during routine examination in a reference hospital. METHOD: First-degree relatives of primary open angle glaucoma patients who accompanied their relatives to the glaucoma service of a reference hospital were screened for glaucoma. RESULTS: One-hundred and one first-degree relatives were examined, of which 56.4% had never had their intraocular pressure measured. 10.9% had previously been diagnosed with glaucoma, and 5.9% were newly diagnosed during this study. CONCLUSIONS: The eye examination of first-degree relatives identified a significant percentage of individuals with glaucoma. Despite being first-degree relatives of glaucoma patients, 56.4% of the companions had never had their eye pressure measured, demonstrating a lack of awareness about this disease.

  18. Report of the eRHIC Ring-Ring Working Group

    Energy Technology Data Exchange (ETDEWEB)

    Aschenauer, E. C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Berg, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Blaskiewicz, M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Brennan, M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Fedotov, A. [Brookhaven National Lab. (BNL), Upton, NY (United States); Fischer, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Litvinenko, V. [Brookhaven National Lab. (BNL), Upton, NY (United States); Montag, C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Palmer, R. [Brookhaven National Lab. (BNL), Upton, NY (United States); Parker, B. [Brookhaven National Lab. (BNL), Upton, NY (United States); Peggs, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ptitsyn, V. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ranjbar, V. [Brookhaven National Lab. (BNL), Upton, NY (United States); Tepikian, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Trbojevic, D. [Brookhaven National Lab. (BNL), Upton, NY (United States); Willeke, F. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-10-13

    This report evaluates the ring-ring option for eRHIC as a lower risk alternative to the linac-ring option. The reduced risk goes along with a reduced initial luminosity performance. However, a luminosity upgrade path is kept open. This upgrade path consists of two branches, with the ultimate upgrade being either a ring-ring or a linac-ring scheme. The linac-ring upgrade could be almost identical to the proposed linac-ring scheme, which is based on an ERL in the RHIC tunnel. This linac-ring version has been studied in great detail over the past ten years, and its significant risks are known. On the other hand, no detailed work on an ultimate performance ring-ring scenario has been performed yet, other than the development of a consistent parameter set. Pursuing the ring-ring upgrade path introduces high risks and requires significant design work that is beyond the scope of this report.

  19. The Use of Sun Elevation Angle for Stereogrammetric Boreal Forest Height in Open Canopies

    Science.gov (United States)

    Montesano, Paul M.; Neigh, Christopher; Sun, Guoqing; Duncanson, Laura Innice; Van Den Hoek, Jamon; Ranson, Kenneth Jon

    2017-01-01

    Stereogrammetry applied to globally available high resolution spaceborne imagery (HRSI; less than 5 m spatial resolution) yields fine-scaled digital surface models (DSMs) of elevation. These DSMs may represent elevations that range from the ground to the vegetation canopy surface, are produced from stereoscopic image pairs (stereo pairs) that have a variety of acquisition characteristics, and have been coupled with lidar data of forest structure and ground surface elevation to examine forest height. This work explores surface elevations from HRSI DSMs derived from two types of acquisitions in open canopy forests. We (1) apply an automated mass-production stereogrammetry workflow to along-track HRSI stereo pairs, (2) identify multiple spatially coincident DSMs whose stereo pairs were acquired under different solar geometry, (3) vertically co-register these DSMs using coincident spaceborne lidar footprints (from ICESat-GLAS) as reference, and(4) examine differences in surface elevations between the reference lidar and the co-registered HRSI DSMs associated with two general types of acquisitions (DSM types) from different sun elevation angles. We find that these DSM types, distinguished by sun elevation angle at the time of stereo pair acquisition, are associated with different surface elevations estimated from automated stereogrammetry in open canopy forests. For DSM values with corresponding reference ground surface elevation from spaceborne lidar footprints in open canopy northern Siberian Larix forests with slopes less than10, our results show that HRSI DSM acquired with sun elevation angles greater than 35deg and less than 25deg (during snow-free conditions) produced characteristic and consistently distinct distributions of elevation differences from reference lidar. The former include DSMs of near-ground surfaces with root mean square errors less than 0.68 m relative to lidar. The latter, particularly those with angles less than 10deg, show distributions with

  20. Comparison of Latanoprost and Brimonidine in the treatment of open angle glaucoma

    Directory of Open Access Journals (Sweden)

    Man Luo

    2015-07-01

    Full Text Available AIM:To compare the efficacy and safety of latanoprost and brimonidine in the treatment of open angle glaucoma, and provide reference for rational drug use. METHODS:A total of 121 cases(136 eyeswho were diagnosed as primary open angle glaucoma were selected in this study, and they were randomly divided into experimental group(62 cases, 70 eyesand control group(59 cases, 66 eyesaccording to different drug treatment. Patients in the control group received brimonidine eye drops twice a day, while patients in the experimental group received latanoprost eye drops once a day. The intraocular pressure, visual acuity and adverse reactions were checked of the two groups in the following 3mo. RESULTS:The intraocular pressure of patients in the control group was 18.1±1.3mmHg, while the experimental group was 17.0±0.9mmHg after 12wk of treatment, which were both lower than before(PCONCLUSION:Latanoprost can significantly reduce intraocular pressure in glaucoma patients with in the follow-up time, and reduce the impact of elevated intraocular pressure in the vision of glaucoma patients, with little adverse reaction, worthy of clinical application.

  1. Cdt1 stabilizes an open MCM ring for helicase loading.

    Science.gov (United States)

    Frigola, Jordi; He, Jun; Kinkelin, Kerstin; Pye, Valerie E; Renault, Ludovic; Douglas, Max E; Remus, Dirk; Cherepanov, Peter; Costa, Alessandro; Diffley, John F X

    2017-06-23

    ORC, Cdc6 and Cdt1 act together to load hexameric MCM, the motor of the eukaryotic replicative helicase, into double hexamers at replication origins. Here we show that Cdt1 interacts with MCM subunits Mcm2, 4 and 6, which both destabilizes the Mcm2-5 interface and inhibits MCM ATPase activity. Using X-ray crystallography, we show that Cdt1 contains two winged-helix domains in the C-terminal half of the protein and a catalytically inactive dioxygenase-related N-terminal domain, which is important for MCM loading, but not for subsequent replication. We used these structures together with single-particle electron microscopy to generate three-dimensional models of MCM complexes. These show that Cdt1 stabilizes MCM in a left-handed spiral open at the Mcm2-5 gate. We propose that Cdt1 acts as a brace, holding MCM open for DNA entry and bound to ATP until ORC-Cdc6 triggers ATP hydrolysis by MCM, promoting both Cdt1 ejection and MCM ring closure.

  2. Risk Factors for Primary Open-Angle Glaucoma in Western Turkey

    Directory of Open Access Journals (Sweden)

    Güliz Fatma Yavaş

    2013-04-01

    Full Text Available Pur po se: To evaluate the prevalence of primary open-angle glaucoma (POAG in subjects aged over 40 years in Western Turkey and to quantify its association with several systemic risk factors. Ma te ri al and Met hod: The research was conducted in Afyonkarahisar, a middle Anatolian city, between November 2005 and February 2006. A total of 1533 subjects aged 40 years or more were included in the study. Diabetes mellitus, hypertension, atherosclerotic cardiac disease, obesity, smoking, alcohol consumption, and dietary habitus (meat, chicken, and fish consumption were asked. Level of blood glucose, serum total cholesterol, triglyceride, high-density lipoprotein, low-density lipoprotein, very-low-density lipoprotein, Vitamin B12, and thyroid-stimulating-hormone were determined. Ophthalmic examination was performed, and intraocular pressure was measured by tonopen. Subjects with an IOP of 21 mmHg or more and/or with a cupping/disc ratio of 0.3 or more were told to come to the clinic for visual field analysis and gonioscopy. Subjects with a typical glaucomatous visual field defect and an open angle were recorded as POAG. Risk factors for POAG were determined by chi-square test. Re sults: Prevalence of POAG was found to be 2% (30 subjects and the only associated risk factor was age (p=0.05. Dietary habitus was also not associated with glaucoma (p>0.05. Dis cus si on: This study provides a population-based data about the prevalence and risk factors of POAG in Turkey. (Turk J Ophthalmol 2013; 43: 87-90

  3. From bicycle chain ring shape to gear ratio: algorithm and examples.

    Science.gov (United States)

    van Soest, A J

    2014-01-03

    A simple model of the bicycle drive system with a non-circular front chain ring is proposed and an algorithm is devised for calculation of the corresponding Gear Ratio As a Function Of Crank Angle (GRAFOCA). It is shown that the true effective radius of the chain ring is always the perpendicular distance between the crank axis and the line through the chain segment between the chain ring and the cog. It is illustrated that the true effective radius of the chain ring at any crank angle may differ substantially from the maximum vertical distance between the crank axis and the chain ring circumference that is used as a proxy for the effective chain ring radius in several studies; in particular, the crank angle at which the effective chain ring radius is maximal as predicted from the latter approach may deviate by as much as 0.30 rad from the true value. The algorithm proposed may help in designing chain rings that achieve the desired GRAFOCA. © 2013 Published by Elsevier Ltd. All rights reserved.

  4. Chemicals from Biomass: Combining Ring-Opening Tautomerization and Hydrogenation Reactions to Produce 1,5-Pentanediol from Furfural.

    Science.gov (United States)

    Brentzel, Zachary J; Barnett, Kevin J; Huang, Kefeng; Maravelias, Christos T; Dumesic, James A; Huber, George W

    2017-04-10

    A process for the synthesis of 1,5-pentanediol (1,5-PD) with 84 % yield from furfural is developed, utilizing dehydration/hydration, ring-opening tautomerization, and hydrogenation reactions. Although this process has more reaction steps than the traditional direct hydrogenolysis of tetrahydrofurfuryl alcohol (THFA), techno-economic analyses demonstrate that this process is the economically preferred route for the synthesis of biorenewable 1,5-PD. 2-Hydroxytetrahydropyran (2-HY-THP) is the key reaction pathway intermediate that allows for a decrease in the minimum selling price of 1,5-PD. The reactivity of 2-HY-THP is 80 times greater than that of THFA over a bimetallic hydrogenolysis catalyst. This enhanced reactivity is a result of the ring-opening tautomerization to 5-hydoxyvaleraldehyde and subsequent hydrogenation to 1,5-PD. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Energy spectra of quantum rings.

    Science.gov (United States)

    Fuhrer, A; Lüscher, S; Ihn, T; Heinzel, T; Ensslin, K; Wegscheider, W; Bichler, M

    2001-10-25

    Quantum mechanical experiments in ring geometries have long fascinated physicists. Open rings connected to leads, for example, allow the observation of the Aharonov-Bohm effect, one of the best examples of quantum mechanical phase coherence. The phase coherence of electrons travelling through a quantum dot embedded in one arm of an open ring has also been demonstrated. The energy spectra of closed rings have only recently been studied by optical spectroscopy. The prediction that they allow persistent current has been explored in various experiments. Here we report magnetotransport experiments on closed rings in the Coulomb blockade regime. Our experiments show that a microscopic understanding of energy levels, so far limited to few-electron quantum dots, can be extended to a many-electron system. A semiclassical interpretation of our results indicates that electron motion in the rings is governed by regular rather than chaotic motion, an unexplored regime in many-electron quantum dots. This opens a way to experiments where even more complex structures can be investigated at a quantum mechanical level.

  6. Catalytic ring-​opening copolymerization of limonene oxide and phthalic anhydride : toward partially renewable polyesters

    NARCIS (Netherlands)

    Hosseini Nejad, E.; Pionasari, A; Melis, van C.G.W.; Koning, C.E.; Duchateau, R.

    2013-01-01

    Catalytic ring-¿opening copolymn. of limonene oxide with phthalic anhydride was performed applying metal t-¿Bu-¿salophen complexes (t-¿Bu-¿salophen)¿MX; M = Cr, X = Cl (1)¿, M = Al, X = Cl (2)¿, M = Co, X = OAc (3)¿, M = Mn, X = Cl (4)¿, t-¿Bu-¿salophen =

  7. Grafting of Ring-Opened Cyclopropylamine Thin Films on Silicon (100) Hydride via UV Photoionization.

    Science.gov (United States)

    Tung, J; Ching, J Y; Ng, Y M; Tew, L S; Khung, Y L

    2017-09-13

    The grafting of cyclopropylamine onto a silicon (100) hydride (Si-H) surface via a ring-opening mechanism using UV photoionization is described here. In brief, radicals generated from the Si-H surface upon UV irradiation were found to behave in classical hydrogen abstraction theory manner by which the distal amine group was first hydrogen abstracted and the radical propagated down to the cyclopropane moiety. This subsequently liberated the strained bonds of the cyclopropane group and initiated the surface grafting process, producing a thin film approximately 10-15 nm in height. Contact angle measurements also showed that such photoionization irradiation had yielded an extremely hydrophilic surface (∼21.3°) and X-ray photoelectron spectroscopy also confirmed the coupling was through the Si-C linkage. However, when the surface underwent high-temperature hydrosilylation (>160 °C), the reaction proceeded predominantly through the nucleophilic NH 2 group to form a Si-N linkage to the surface. This rendered the surface hydrophobic and hence suggested that the Si-H homolysis model may not be the main process. To the best of our knowledge, this was the first attempt reported in the literature to use photoionization to directly graft cyclopropylamine onto a silicon surface and in due course generate a highly rich NH-terminated surface that was found to be highly bioactive in promoting cell viability on the basis of 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide studies.

  8. Lipase catalyzed HEMA initiated ring-opening polymerization: In situ formation of mixed polyester methacrylates by transesterification

    NARCIS (Netherlands)

    Takwa, M.; Xiao, Y.; Simpson, N.; Malmstrom, E.; Hult, K.; Koning, C.E.; Heise, A.; Martinelle, M.

    2008-01-01

    2-Hydroxyethyl methacrylate (HEMA) was used as initiator for the enzymatic ring-opening polymerization (ROP) of ¿-pentadecalactone (PDL) and e-caprolactone (CL). The lipase B from Candida antarctica was found to catalyze the cleavage of the ester bond in the HEMA end group of the formed polyesters,

  9. Ring-opening polymerization of ω-pentadecalactone catalyzed by phosphazene superbases

    KAUST Repository

    Ladelta, Viko

    2016-12-12

    A fast and living ring-opening polymerization (ROP) of ω-pentadecalactone (PDL), a representative monomer of macrolactones, was achieved using a primary alcohol as the initiator and t-BuP or t-octP as the catalyst. The use of t-BuP instead of the t-BuP superbase slows down the polymerization rate. The ROP of PDL proceeds to high conversion not only at 80 °C in bulk but also at room temperature and in dilute solution. The synthesized PDL homopolymers and block copolymers with poly(ethylene glycol) were characterized by high-temperature GPC (HT-GPC), H NMR and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). Melting temperatures, determined by differential scanning calorimetry, are also reported.

  10. Ring-opening polymerization of ω-pentadecalactone catalyzed by phosphazene superbases

    KAUST Repository

    Ladelta, Viko; Bilalis, Panayiotis; Gnanou, Yves; Hadjichristidis, Nikolaos

    2016-01-01

    A fast and living ring-opening polymerization (ROP) of ω-pentadecalactone (PDL), a representative monomer of macrolactones, was achieved using a primary alcohol as the initiator and t-BuP or t-octP as the catalyst. The use of t-BuP instead of the t-BuP superbase slows down the polymerization rate. The ROP of PDL proceeds to high conversion not only at 80 °C in bulk but also at room temperature and in dilute solution. The synthesized PDL homopolymers and block copolymers with poly(ethylene glycol) were characterized by high-temperature GPC (HT-GPC), H NMR and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). Melting temperatures, determined by differential scanning calorimetry, are also reported.

  11. open angle glaucoma (poag)?

    African Journals Online (AJOL)

    there is a build up of pressure due to poor outflow of aqueous humor. The outflow obstruction could occur at the trabecular meshwork of the anterior chamber angle or subsequently in the episcleral vein due to raised venous pressure. Such build up of pressure results in glaucoma . Elevated intraocular pressure remains the ...

  12. Cascade synthesis of chiral block copolymers combining lipase catalyzed ring opening polymerization and atom transfer radical polymerization

    NARCIS (Netherlands)

    Peeters, J.W.; Palmans, A.R.A.; Veld, M.A.J.; Scheijen, F.J.E.; Heise, A.; Meijer, E.W.

    2004-01-01

    The enantioselective polymerization of methyl-substituted -caprolactones using Novozym 435 as the catalyst was investigated. All substituted monomers could be polymerized except 6-methyl--caprolactone (6-MeCL), which failed to propagate after ring opening. Interestingly, an odd-even effect in the

  13. Ring-Opening Polymerization of N-Carboxyanhydrides for Preparation of Polypeptides and Polypeptide-Based Hybrid Materials with Various Molecular Architectures

    KAUST Repository

    Pahovnik, David; Hadjichristidis, Nikolaos

    2015-01-01

    Different synthetic approaches utilizing ring-opening polymerization of N-carboxyanhydrides for preparation of polypeptide and polypeptide-based hybrid materials with various molecular architectures are described. An overview of polymerization

  14. A Bacon Tone Ring on an Open-Back Banjo

    OpenAIRE

    Politzer, David

    2016-01-01

    Head taps on a new Goodtime banjo rim fitted with a reproduction Bacon Professional ff tone ring are contrasted with a new Goodtime, a 2002 Goodtime, and a 1999 Goodtime fitted with a 1/4′′ diameter brass ring. Conclusions: The 1/4" ring does what’s commonly imagined, the upgrades to the Goodtime over the years are not merely cosmetic, and the Bacon ring’s biggest effect is to damp head ringing and suppress high harmonics. Detailed comparisons of the new Goodtimes with and without the Bacon r...

  15. Simulation analysis of the effects of an initial cone position and opening angle on a cone-guided implosion

    Energy Technology Data Exchange (ETDEWEB)

    Yanagawa, T. [Department of Physics, Nagoya University, Furo-cho, Chikusa-ku, Nagoya, Aichi 464-8602 (Japan); Sakagami, H. [Fundamental Physics Simulation Division, National Institute for Fusion Science, Oroshi-cho, Toki, Gifu 509-5292 (Japan); Nagatomo, H. [Institute of Laser Engineering, Osaka University, Suita, Osaka 565-0871 (Japan)

    2013-10-15

    In inertial confinement fusion, the implosion process is important in forming a high-density plasma core. In the case of a fast ignition scheme using a cone-guided target, the fuel target is imploded with a cone inserted. This scheme is advantageous for efficiently heating the imploded fuel core; however, asymmetric implosion is essentially inevitable. Moreover, the effect of cone position and opening angle on implosion also becomes critical. Focusing on these problems, the effect of the asymmetric implosion, the initial position, and the opening angle on the compression rate of the fuel is investigated using a three-dimensional pure hydrodynamic code.

  16. Uteroglobin and FLRG concentrations in aqueous humor are associated with age in primary open angle glaucoma patients.

    Science.gov (United States)

    Ashworth Briggs, Esther L; Toh, Tze'Yo; Eri, Rajaraman; Hewitt, Alex W; Cook, Anthony L

    2018-02-27

    The pathophysiological changes occurring in the trabecular meshwork in primary open angle glaucoma are poorly understood, but are thought to include increased extracellular matrix deposition, trabecular meshwork cell apoptosis, inflammation, trabecular meshwork calcification and altered protein composition of the aqueous humor. Although many proteins are present in aqueous humor, relatively few have been studied extensively, and their potential roles in primary open angle glaucoma are unknown. Analyte concentrations in aqueous humor from 19 primary open angle glaucoma and 18 cataract patients were measured using a multiplex immunoassay. Fisher's exact test was used to assess statistical significance between groups, and correlations of analyte concentrations with age, intraocular pressure, pattern standard deviation, mean deviation, cup-to-disc ratio and disease duration since commencing treatment were tested by Spearman's method. CHI3L1, FLRG, HGF, MIF, P-selectin and Uteroglobin were detected in more than 50% of samples of one or both patient groups, some of which have not previously been quantified in aqueous humor. In the glaucoma but not the cataract group, significant correlations were determined with age for Uteroglobin/SCGB1A1 (r s  = 0.805, p < 0.0001) and FLRG (r s  = 0.706, p = 0.0007). Furthermore, HGF correlated significantly with disease duration (r s  = - 0.723, p = 0.0007). There were no differences in analyte concentrations between groups, and no other significant associations with clinical descriptors that passed correction for multiple testing. The correlations of uteroglobin and FLRG with age in primary open angle glaucoma but not cataract may suggest a heightened requirement for anti-inflammatory (uteroglobin) or anti-calcification (FLRG) activity in the ageing glaucomatous trabecular meshwork.

  17. Lactate Dehydrogenase and Oxidative Stress Activity in Primary Open-Angle Glaucoma Aqueous Humour

    Directory of Open Access Journals (Sweden)

    Predrag Jovanović

    2010-02-01

    Full Text Available Lactate dehydrogenase (LDH and lactate are some of the hypoxy biochemical parameters. Extracellular activity of this enzyme increases under the condition of oxidative stress, since the cell integrity can be disrupted during the lipid peroxidation process. Subsequently that leads to the increase level of the lactic acid and lactic acid salts. The objective of this investigation is establishing the level of LDH, LDH1 (HBDH and the lactate concentration in aqueous humour in patients with primary open-angle glaucoma.Biochemical analysis have been made by enzymatic-colometric method (lactate and UV-kinetic method (LDH and HBDH in aqueous humour of 30 patients (42 eyes with primary open-angle glaucoma (POAG and 30 patients (40 eyes with cataract (the control group.The increased values of lactate and the activity of LDH and HBDH enzyme in aqueous humour of POAG patients in correlation with the control group are the results not only of oxidative stress but also of hypoxy and the mitochondry oxidative function (p<0,001.The increased activity of the examined biochemical parameters in the aqueous humour of the POAG patients points to the fact that other mechanisms, besides IOP, have a role in glaucoma pathogenesis.

  18. Chemistry of [(Perfluoroalkyl)Methyl] Oxiranes. Regioselectivity of Ring Opening with O-Nucleophiles and the Preparation of Amphiphilic Monomers

    Czech Academy of Sciences Publication Activity Database

    Církva, Vladimír; Améduri, B.; Boutevin, B.; Paleta, O.

    1997-01-01

    Roč. 84, č. 1 (1997), s. 53-61 ISSN 0022-1139 Institutional research plan: CEZ:AV0Z4072921 Keywords : fluoroalkyl thiiranes * nucleophilic oxirane ring opening Subject RIV: CC - Organic Chemistry Impact factor: 0.714, year: 1997

  19. Synthesis and study of rare earth ortho-hydroxyphenyliminodiacetates with open lactone ring

    International Nuclear Information System (INIS)

    Martynenko, L.I.; Mitrofanova, N.D.; Muratova, N.M.; Kurbatova, S.V.

    1978-01-01

    New La, Pr, Nd, Sm, Dy, Er, and Y o-oxyphenyliminodiacetates of Ln 2 (HL) 3 xnH 2 O composition have been synthesized using the reaction of Ln chloride solutions with o-oxyphenyliminodiacetic acid previously converted into a soluble K 2 HL salt. According to the data of infrared spectra, the ligand contains an open lactone ring and ionized carboxylic groups. At the temperature of 80-190 deg the complexes undergo dehydration. The order of dehydration reaction for La, Nd, and Y complexes is equal to 2, activation energies are equal to 16.9, 12.5 and 13.2 kcal/mol, respectively

  20. Photochemical Ring-Opening Reaction in 2(1H)-Pyrimidinones: A Matrix Isolation Study

    OpenAIRE

    Lapinski, Leszek; Rostkowska, Hanna; Khvorostov, Artem; Fausto, Rui; Nowak, Maciej J.

    2003-01-01

    Photoreactions induced by UV-B (290−320 nm) irradiation were studied for 1-methyl-2(1H)-pyrimidinone and 1-methylcytosine monomers isolated in low-temperature inert gas matrixes. A Norrish type I α-cleavage reaction leading to open-ring conjugated isocyanate was observed for 1-methyl-2(1H)-pyrimidinone. The structure of the photoproduct was identified by comparison of its experimental IR spectrum with the spectrum theoretically calculated at the DFT(B3LYP)/6-31++G(d,p) level. The main indicat...

  1. (Salen)Ti(Ⅳ)-Catalyzed Asymmetric Ring-opening of meso Epoxides Using Dithiophosphorus Acid as the Nucleophile

    Institute of Scientific and Technical Information of China (English)

    Zheng Hong ZHOU; Zhao Ming LI; Bing LIU; Kang Ying LI; Li Xin WANG; Guo Feng ZHAO; Qi Lin ZHOU; Chu Chi TANG

    2006-01-01

    The asymmetric ring-opening of epoxides with dithiophosphorus acids catalyzed by a (salen)Ti(Ⅳ) complex formed in situ from the reaction of Ti(OPr-i)4 and the chiral Schiff base derived from (1R,2R)-(+)-diaminocyclohexane was realized. The resulting products were obtained with low to good enantioselectivity (up to 73% ee).

  2. Clinical results of Trabectome surgery for open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    Mizoguchi T

    2015-10-01

    Full Text Available Takanori Mizoguchi,1 Shiro Nishigaki,2 Tomoki Sato,3 Harumi Wakiyama,4 Nobuchika Ogino2 1Mizoguchi Eye Clinic, Ophthalmology, Sasebo, 2Nishigaki Eye Clinic, Ophthalmology, Nagoya, 3Sato Eye Clinic, Ophthalmology, Arao, 4Japanese Red Cross Nagasaki Genbaku Hospital, Nagasaki, Japan Background: The purpose of this study was to determine outcomes when using Trabectome surgery and to evaluate factors associated with its effects in primary open-angle glaucoma (POAG and exfoliation glaucoma (EXG. Methods: This was a prospective, non-randomized, observational, comparative cohort study in which Trabectome surgery was used alone in patients with POAG or EXG. Trabectome surgery was considered to have failed when at least one of the following three criteria was fulfilled: intraocular pressure (IOP ≥21 mmHg and a <20% reduction below the baseline IOP on two consecutive follow-up visits 3 months or more after surgery; need for additional glaucoma surgery; and an increase in number of medications compared with baseline. Results: The subjects were 32 males (34 eyes and 46 females (48 eyes. POAG was observed in 43 eyes and EXG in 39 eyes. IOP after Trabectome surgery decreased significantly from 22.3±6.8 mmHg at baseline to 14.0±3.9 mmHg (23.0% reduction at month 24 in all cases (P<0.0000. The success rate at 2 years was 51.2% for all cases (POAG, 50.9%; EXG, 49.2%. There was no significant difference in success rate between POAG and EXG (P=0.91. Preoperative IOP (P=0.033 and number of medications (P=0.041 were significant factors for surgical success/failure in multivariate logistic regression. No serious complications were observed. Conclusion: Trabectome surgery achieved favorable IOP control and was equally effective in patients with POAG and those with EXG. Its effects were influenced by preoperative IOP and number of preoperative medications. Keywords: Trabectome, primary open-angle glaucoma, exfoliation glaucoma, success rate, risk factors 

  3. Zirconium(IV)-Catalyzed Ring Opening of on-DNA Epoxides in Water.

    Science.gov (United States)

    Fan, Lijun; Davie, Christopher P

    2017-05-04

    DNA-encoded library technology (ELT) has spurred wide interest in the pharmaceutical industry as a powerful tool for hit and lead generation. In recent years a number of "DNA-compatible" chemical modifications have been published and used to synthesize vastly diverse screening libraries. Herein we report a newly developed, zirconium tetrakis(dodecyl sulfate) [Zr(DS) 4 ] catalyzed ring-opening of on-DNA epoxides in water with amines, including anilines. Subsequent cyclization of the resulting on-DNA β-amino alcohols leads to a variety of biologically interesting, nonaromatic heterocycles. Under these conditions, a library of 137 million on-DNA β-amino alcohols and their cyclization products was assembled. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. The functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation

    Directory of Open Access Journals (Sweden)

    Kaykhosro Mardanpour

    2011-07-01

    Full Text Available Background:Unstable Pelvic fracture,a result of high energy antero-posterior compression injury, has been managed based on internal fixation and open reduction. The mode of fixation in Unstable Pelvic fracture has, however, been a subject of controversy and some authors have proposed a need to address the issue of partial breach of the pelvic ring elements in these injuries. This study was performed to evaluate the functional and radiological results of treatment of pelvic ring fractures by open reduction, internal fixation. Methods: Thirty eight patients with unstable pelvic fractures, treated from 2002 to2008 were retrospectively reviewed. The mean age of patients’ was 37 years old (range 20 to 67. Twenty six patients were men and 12 women. The most common cause was a road traffic accident (N=37, 97%. There were 11 type-C and 27 type-B fractures according to Tile’s classification. Thirty six patients sustained additional injuries. The most prevalent additional injuries were lower extremity fractures. Open reduction, internal fixation as a definite management was applied for all patients. Quality of reduction was graded according to the grades proposed by Matta and Majeed’s score was used to assess the clinical outcome. The mean period of follow-up was 25 months (ranged from 6 to 109 months. About 81.6% of patients had either good or excellent radiological reduction. Results: The functional outcome was excellent in 66%, good in 15%, fair in 11% and poor in 7% of the patients. There were 4 postoperative infections. No sexual function problem was reported. Nerve deficits recovered completely in 2 and partially in 3 of 11 patients with preoperative neurologic deficiency. There was no significant relation between functional outcome and the site of fracture Conclusion: Unstable pelvic ring fracture injuries should be managed surgically by rigid stabilization that must be carried out as soon as the general ndition of the patient permits, and

  5. Structure-function correlations using scanning laser polarimetry in primary angle-closure glaucoma and primary open-angle glaucoma.

    Science.gov (United States)

    Lee, Pei-Jung; Liu, Catherine Jui-Ling; Wojciechowski, Robert; Bailey-Wilson, Joan E; Cheng, Ching-Yu

    2010-05-01

    To assess the correlations between retinal nerve fiber layer (RNFL) thickness measured with scanning laser polarimetry and visual field (VF) sensitivity in primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG). Prospective, comparative, observational cases series. Fifty patients with POAG and 56 patients with PACG were examined using scanning laser polarimetry with variable corneal compensation (GDx VCC; Laser Diagnostic Technologies, Inc.) and Humphrey VF analyzer (Carl Zeiss Meditec, Inc.) between August 2005 and July 2006 at Taipei Veterans General Hospital. Correlations between RNFL thickness and VF sensitivity, expressed as mean sensitivity in both decibel and 1/Lambert scales, were estimated by the Spearman rank correlation coefficient (r(s)) and multivariate median regression models (pseudo R(2)). The correlations were determined globally and for 6 RNFL sectors and their corresponding VF regions. The correlation between RNFL thickness and mean sensitivity (in decibels) was weaker in the PACG group (r(s) = 0.38; P = .004; pseudo R(2) = 0.17) than in the POAG group (r(s) = 0.51; P polarimetry. Compared with eyes with POAG, fewer RNFL sectors have significant structure-function correlations in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.

  6. Early Clinical Results of a Novel Ab Interno Gel Stent for the Surgical Treatment of Open-angle Glaucoma.

    Science.gov (United States)

    Sheybani, Arsham; Dick, H Burkhard; Ahmed, Iqbal I K

    2016-07-01

    To evaluate the intraocular pressure (IOP) lowering effect of the XEN140 microfistula gel stent implant for the surgical treatment of open-angle glaucoma. Forty-nine eyes of 49 patients with an IOP>18 mm Hg and ≤35 mm Hg were studied in a prospective nonrandomized multicenter cohort trial of the surgical implantation of the XEN140 implant in patients with open-angle glaucoma. Complete success was defined as a postoperative IOP≤18 mm Hg with ≥20% reduction in IOP at 12 months without any glaucoma medications. Failure was defined as vision loss of light perceptions vision or worse, need for additional glaucoma surgery, or glaucoma.

  7. Device for monitoring electron-ion ring parameters

    International Nuclear Information System (INIS)

    Tyutyunnikov, S.I.; Shalyapin, V.N.

    1982-01-01

    The invention is classified as the method of collective ion acceleration. The device for electron-ion ring parameters monitoring is described. The invention is aimed at increasing functional possibilities of the device at the expense of the enchance in the number of the ring controlled parameters. The device comprises three similar plane mirrors installed over accelerating tube circumference and a mirror manufactured in the form of prism and located in the tube centre, as well as the system of synchrotron radiation recording and processing. Two plane mirrors are installed at an angle of 45 deg to the vertical axis. The angle of the third plane mirror 3 α and that of prismatic mirror 2 α to the vertical axis depend on geometric parameters of the ring and accelerating tube and they are determined by the expression α=arc sin R K /2(R T -L), where R K - ring radius, R T - accelerating tube radius, L - the height of segment, formed by the mirror and inner surface of the accelerating tube. The device suggested permits to determine longitudinal dimensions of the ring, its velocity and the number of electrons and ions in the ring

  8. Tafluprost once daily for treatment of elevated intraocular pressure in patients with open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    Liu Y

    2012-12-01

    Full Text Available Yang Liu, Weiming MaoDepartment of Cell Biology and Anatomy, North Texas Eye Research Institute, University of North Texas Health Science Center, Fort Worth, TXAbstract: Glaucoma is a leading cause of visual loss worldwide. Current antiglaucoma therapy focuses on lowering intraocular pressure to a safe level. In recent years, prostaglandin analogs have become the first-line agents for treating open angle glaucoma. Tafluprost, which was first reported in 2003, is a novel prostaglandin analog, and has been shown to be a potent ocular hypotensive agent in a number of preclinical and clinical studies. Also, its unique preservative-free formulation helps to decrease preservative-associated ocular disorders and improve patient compliance. In this review, studies from 2003 to 2012 focusing on the structure, metabolism, efficacy, and safety of tafluprost are summarized. These studies suggested that application of tafluprost once daily is a safe and effective treatment for patients with open angle glaucoma.Keywords: tafluprost, prostaglandin analog, glaucoma, intraocular pressure, preservative-free formulation

  9. The RAND Consensus Study for Primary Open-Angle Glaucoma in Latin America

    OpenAIRE

    Paulo E.C. Dantas

    2013-01-01

    Abstract Purpose: To report the results of a Latin American (LA) consensus panel regarding the diagnosis and management of primary open angle glaucoma, and to compare these results with those from a similar panel in the United States (US). Design: A RAND-like appropriateness methodology was used to assess glaucoma practice in LA. Methods: The 148 polling statements created for the RAND- like analysis in the US and 10 additional statements specific to glaucoma care in LA were presented to a pa...

  10. The Ex-PRESS glaucoma shunt versus trabeculectomy in open-angle glaucoma: a prospective randomized study

    NARCIS (Netherlands)

    de Jong, Leo A. M. S.

    2009-01-01

    The purpose of this study was to establish the efficacy and safety of the Ex-PRESS (Optonol Ltd., Neve Ilan, Israel) mini glaucoma shunt in open-angle glaucoma. This was a prospective, randomized trial. Eyes from enrolled patients were randomly assigned to either Ex-PRESS implantation under a

  11. Development of high-speed reactive processing system for carbon fiber-reinforced polyamide-6 composite: In-situ anionic ring-opening polymerization

    International Nuclear Information System (INIS)

    Kim, Sang-Woo; Seong, Dong Gi; Yi, Jin-Woo; Um, Moon-Kwang

    2016-01-01

    In order to manufacture carbon fiber-reinforced polyamide-6 (PA-6) composite, we optimized the reactive processing system. The in-situ anionic ring-opening polymerization of ε-caprolactam was utilized with proper catalyst and initiator for PA-6 matrix. The mechanical properties such as tensile strength, inter-laminar shear strength and compressive strength of the produced carbon fiber-reinforced PA-6 composite were measured, which were compared with the corresponding scanning electron microscope (SEM) images to investigate the polymer properties as well as the interfacial interaction between fiber and polymer matrix. Furthermore, kinetics of in-situ anionic ring-opening polymerization of ε-caprolactam will be discussed in the viewpoint of increasing manufacturing speed and interfacial bonding between PA-6 matrix and carbon fiber during polymerization.

  12. Development of high-speed reactive processing system for carbon fiber-reinforced polyamide-6 composite: In-situ anionic ring-opening polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang-Woo; Seong, Dong Gi; Yi, Jin-Woo; Um, Moon-Kwang [Composites Research Division, Korea Institute of Materials Science (KIMS), Changwon, Gyeongnam, 642–831 (Korea, Republic of)

    2016-05-18

    In order to manufacture carbon fiber-reinforced polyamide-6 (PA-6) composite, we optimized the reactive processing system. The in-situ anionic ring-opening polymerization of ε-caprolactam was utilized with proper catalyst and initiator for PA-6 matrix. The mechanical properties such as tensile strength, inter-laminar shear strength and compressive strength of the produced carbon fiber-reinforced PA-6 composite were measured, which were compared with the corresponding scanning electron microscope (SEM) images to investigate the polymer properties as well as the interfacial interaction between fiber and polymer matrix. Furthermore, kinetics of in-situ anionic ring-opening polymerization of ε-caprolactam will be discussed in the viewpoint of increasing manufacturing speed and interfacial bonding between PA-6 matrix and carbon fiber during polymerization.

  13. Developing new methods for the mono-end functionalization of living ring opening metathesis polymers.

    Science.gov (United States)

    Kilbinger, Andreas F M

    2012-01-01

    In this article we present a review of our recent results in one area of research we are involved in. All research efforts in our group focus on functional polymers and new ways of gaining higher levels of control with regard to the placement of functional groups within these polymers. Here, the living ring opening metathesis polymerization (ROMP) will be reviewed for which end-functionalization methods had been rare until very recently. Polymers carrying particular functional groups only at the chain-ends are, however, very interesting for a variety of industrial and academic applications. Polymeric surfactants and polymer-protein conjugates are two examples for the former and polymer-β-sheet-peptide conjugates one example for the latter. The functionalization of macroscopic or nanoscopic surfaces often relies on mono-end functional polymers. Complex macromolecular architectures are often constructed from macromolecules carrying exactly one functional group at their chain- end. The ring opening metathesis polymerization is particularly interesting in this context as it is one of the most functional group tolerant polymerization methods known. Additionally, high molecular weight polymers are readily accessible with this technique, a feature that living radical polymerizations often struggle to achieve. Finding new ways of functionalizing the polymer chain-end of ROMP polymers has therefore been a task long overdue. Here, we present our contribution to this area of research.

  14. Zwitterionic bis(phenolate)amine lanthanide complexes for the ring-opening polymerisation of cyclic esters

    NARCIS (Netherlands)

    Dyer, H.E.; Huijser, S.; Schwarz, A.D.; Wang, Chao; Duchateau, R.; Mountford, P.

    2008-01-01

    The reaction of Sm{N(SiMe3)2}3 with the bis(phenol)amines H2O2NR (H2O 2NR = RCH2CH2N(2-HO-3,5-C 6H2tBu2)2; R = OMe, NMe2 or Me) gave exclusively zwitterions Sm(O2N R)(HO2NR). For R = OMe or NMe2 these were efficient catalysts for the ring-opening polymerisation of e-caprolactone and d,l-lactide with

  15. Study of RF system of Hefei storage ring under injection

    International Nuclear Information System (INIS)

    Xu Hongliang; Wang Lin; Li Yongjun; Huang Guirong; Zhang Pengfei; Li Weimin; Liu Zuping; He Duohui

    2004-01-01

    In this paper, the beam loading effect of RF system and the conditions of Robinson instability are analyzed in detail. By the study of the injection beam intensity limit dependent on detune angle and visible detune angle, it is found that the storage ring can be injected to more than 300 mA current intensity to attain the design target of phase II project in the lower energy injection situation of Hefei Storage Ring if a certain power is feed in the RF cavity and a certain tuning angle of the RF cavity is set

  16. Research Update: A hafnium-based metal-organic framework as a catalyst for regioselective ring-opening of epoxides with a mild hydride source

    International Nuclear Information System (INIS)

    Stephenson, Casey J.; Hassan Beyzavi, M.; Klet, Rachel C.; Hupp, Joseph T.; Farha, Omar K.

    2014-01-01

    Reaction of styrene oxide with sodium cyanoborohydride and a catalytic amount of Hf-NU-1000 yields the anti-Markovnikov product, 2-phenylethanol, with over 98% regioselectivity. On the other hand, propylene oxide is ring opened in a Markovnikov fashion to form 2-propanol with 95% regioselectivity. Both styrene oxide and propylene oxide failed to react with sodium cyanoborohydride without the addition of Hf-NU-1000 indicative of the crucial role of Hf-NU-1000 as a catalyst in this reaction. To the best of our knowledge, this is the first report of the use of a metal-organic framework material as a catalyst for ring-opening of epoxides with hydrides

  17. Peptide block copolymers by N-carboxyanhydride ring-opening polymerization and atom transfer radical polymerization: The effect of amide macroinitiators

    NARCIS (Netherlands)

    Habraken, G.J.M.; Koning, C.E.; Heise, A.

    2009-01-01

    The synthesis of polypeptide-containing block copolymers combining N-carboxyanhydride (NCA) ring-opening polymerization and atom transfer radical polymerization (ATRP) was investigated. An amide initiator comprising an amine function for the NCA polymerization and an activated bromide for ATRP was

  18. Myocardial infarction increases progressive visual field defects in well treated early primary open angle glaucoma--a prospective case control study.

    Science.gov (United States)

    Mondal, Lakshmikanta; Baidya, Krishnapada; Choudhury, Himadri; Roy, Rupam

    2013-06-01

    The purpose of the study was to evaluate the progression of glaucomatous field damage in patients with stable primary open angle glaucoma after an attack of myocardial infarction. In this case control study, 62 open angle glaucoma patients were selected and regularly followed up. Among 62 patients, 9 had an attack of myocardial infarction. The intra-ocular pressure and visual field progression of both the groups (myocardial infarction versus no myocardial infarction) were analysed. Three (33.3%) out of 9 patients who had suffered from myocardial infarction showed progressive visual field loss whereas only 9 (16.9%) out of 53 patients who did not suffer from myocardial infarction, showed progressive field changes. Both the groups had stable target intra-ocular pressure between 14 and 16 mm Hg. Myocardial infarction may adversely influence the progression of primary open angle glaucoma which is suspected to result from ischaemia induced neuronal loss and only control of intraocular pressure is not the only solution. We have to look for other drugs that prevents ischaemia induced neuronal damage.

  19. Chronic infection is as one of а possible risk factors in development open angle glaucoma

    Directory of Open Access Journals (Sweden)

    E. V. Boiko

    2011-01-01

    Full Text Available This review is about analysis of data possible role of the infectious factor in development open-angle glaucoma. The obstruction of ways of outflow  s an important role in increase of intraocular pressure. The reason can be various infectious agents, including Chlamydia trachomatis, Mycoplasma pneumoniae, Mycoplasma hominis, Ureaplasma urealyticum and B.fragilis. There were separate publications during last years, which are devoted to studying a role of proinflammatory cytotoxicants, they show the role of the inflammatory factor in pathogenesis of glaucomatical process. In the literary data we can see role of infections which are show communication between ontamination of bacteriumНelicobacter pylori and glaucoma development. There is data that patients with open-angle glaucoma in 63% have high level of shooting galleries of antibodies IgG in blood to C. pneumoniae. It is connected with infringement of optic disc food as a result of influence C. pneumoniae on its vascular system.

  20. A detailed kinetic study of the direct ring opening of cyclohexane and methylcyclohexane over monofunctional Ir/Al{sub 2}O{sub 3} catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Hui; Gutierrez, O.Y.; Lercher, J.A. [Technische Univ. Muenchen (Germany). Catalysis Research Center

    2011-07-01

    The present study analyses a series of Al{sub 2}O{sub 3}-supported iridium catalysts with different pretreatments and addresses the kinetic features and structural requirements of direct ring opening of cyclohexane and methylcyclohexane catalyzed by Ir in absence of acid-catalyzed ring contraction. Mild reaction conditions and high H{sub 2}/hydrocarbon ratios (200-1000) were used to improve accuracy of kinetic measurements and to negate deactivation. Isomerization and dehydrogenation pathways were suppressed to low extents (1-5%) over the weakly acidic catalysts under the reaction conditions applied. Three main observations are shown: 1) initial selectivity to ring opening products (ROPs) increases with iridium dispersion; 2) optimal H{sub 2} pressures differ not only between primary and secondary products, but also among ROPs and fragments; 3) the air-calcination step before catalyst reduction imposes a significant impact on both activity and product distribution. (orig.)

  1. Structural brain alterations in primary open angle glaucoma: a 3T MRI study

    OpenAIRE

    Jieqiong Wang; Ting Li; Bernhard A. Sabel; Zhiqiang Chen; Hongwei Wen; Jianhong Li; Xiaobin Xie; Diya Yang; Weiwei Chen; Ningli Wang; Junfang Xian; Huiguang He

    2016-01-01

    Glaucoma is not only an eye disease but is also associated with degeneration of brain structures. We now investigated the pattern of visual and non-visual brain structural changes in 25 primary open angle glaucoma (POAG) patients and 25 age-gender-matched normal controls using T1-weighted imaging. MRI images were subjected to volume-based analysis (VBA) and surface-based analysis (SBA) in the whole brain as well as ROI-based analysis of the lateral geniculate nucleus (LGN), visual cortex (V1/...

  2. Numerical simulation study on new RF system of Hefei storage ring

    International Nuclear Information System (INIS)

    Xu Hongliang; Wang Lin; Huang Guirong; Zhang Pengfei; Li Weimin; Liu Zuping; He Duohui

    2005-01-01

    The two injection ways of new RF system of Hefei storage ring were discussed. In the process of both large detuning injection and tuning injection, the variation of tuning angle and visual detuning angle with beam current intensity was analyzed. The calculation results show that the two injection ways are manipulable for new RF system in phase II project of Hefei storage ring. (author)

  3. Short-term effect of latanoprost and timolol eye drops on tear fluid and the ocular surface in patients with primary open-angle glaucoma and ocular hypertension

    DEFF Research Database (Denmark)

    Thygesen, John; Aaen, Kim; Theodorsen, F.

    2000-01-01

    ophthalmology, open-angle glaucoma, ocular hypertension, glaucoma therapy, latanoprost, timolol, Rose-Bengal test, break-up time, Schirmer-1-test, conjunctival impression cytology......ophthalmology, open-angle glaucoma, ocular hypertension, glaucoma therapy, latanoprost, timolol, Rose-Bengal test, break-up time, Schirmer-1-test, conjunctival impression cytology...

  4. Diagnostic accuracy of the parameters from ganglion cell complex map, evaluated with SD-OCT in primary open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    B. Anguelov

    2014-10-01

    Full Text Available Purpose: To evaluate the sensitivity and specificity of ganglion cell complex (GCC parameters, obtained with optical coherence tomography (OCT and to determine their accuracy and ability to differentiate healthy from primary open-angle glaucoma patients. Patients and methods. 84 eyes of primary open-angle glaucoma patients and 40 eyes of healthy individuals were enrolled in the study. All of them underwent complete eye examination, including standard automated perimetry (HFA II and OCT (RTVue-100. Avg. GCC (average GCC, Sup. GCC (superior GCC, Inf. GCC (inferior GCC, GLV (globаl loss volume, FLV (focal loss volume and RNFL (retinal nerve fiber layer — ONH map were measured. ROC curveswere created and sensitivity and specificity were calculated for each of these parameters.Results.The highest sensitivity and specificity was found for GLV and the lowest for Sup. GCC. Area under the ROC curves (AUC for GLV was found to be the largest and the smallest for Sup. GCC.Conclusion. Parameters from GCC map have high sensitivity and specificity. Their diagnostic capability is similar, even slightly better than the one of RNFL. GLV has the highest diagnostic accuracy for primary open-angle glaucoma detection in this study.

  5. Highly Defined Multiblock Copolypeptoids: Pushing the Limits of Living Nucleophilic Ring-Opening Polymerization

    KAUST Repository

    Fetsch, Corinna

    2012-06-05

    Advanced macromolecular engineering requires excellent control over the polymerization reaction. Living polymerization methods are notoriously sensitive to impurities, which makes a practical realization of such control very challenging. Reversible-deactivation radical polymerization methods are typically more robust, but have other limitations. Here, we demonstrate by repeated (ge;10 times) chain extension the extraordinary robustness of the living nucleophilic ring-opening polymerization of N-substituted glycine N-carboxyanhydrides, which yields polypeptoids. We observe essentially quantitative end-group fidelity under experimental conditions that are comparatively easily managed. This is employed to synthesize a pentablock quinquiespolymer with high definition. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Highly Defined Multiblock Copolypeptoids: Pushing the Limits of Living Nucleophilic Ring-Opening Polymerization

    KAUST Repository

    Fetsch, Corinna; Luxenhofer, Robert

    2012-01-01

    Advanced macromolecular engineering requires excellent control over the polymerization reaction. Living polymerization methods are notoriously sensitive to impurities, which makes a practical realization of such control very challenging. Reversible-deactivation radical polymerization methods are typically more robust, but have other limitations. Here, we demonstrate by repeated (ge;10 times) chain extension the extraordinary robustness of the living nucleophilic ring-opening polymerization of N-substituted glycine N-carboxyanhydrides, which yields polypeptoids. We observe essentially quantitative end-group fidelity under experimental conditions that are comparatively easily managed. This is employed to synthesize a pentablock quinquiespolymer with high definition. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. A novel report on Eosin Y functionalized MWCNT as an initiator for ring opening polymerization of {epsilon}-caprolactone

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Hung-Hsia; Anbarasan, R.; Kuo, Long-Sheng [MEMS Thermal Control Lab, Department of Mechanical Engineering, National Taiwan University, Taipei 10617, Taiwan (China); Chen, Ping-Hei, E-mail: phchen@ntu.edu.tw [MEMS Thermal Control Lab, Department of Mechanical Engineering, National Taiwan University, Taipei 10617, Taiwan (China)

    2011-04-15

    Research highlights: {yields} In the present investigation, first, we functionalized the MWCNT with Eosin Y dye, for the ring opening polymerization. {yields} The dye functionalized MWCNT acted as an effective initiator which was further confirmed by various analytical techniques. {yields} By this methodology we saved the number of reaction steps, reaction time and also an economically cheaper one. - Abstract: This research conducted ring opening polymerization (ROP) of {epsilon}-caprolactone (C.L.) with a novel initiator, namely; Eosin Y functionalized multiwalled carbon nanotube (MWCNT) at 140 deg. C with nitrogen sparge under different concentrations. ROP of C.L. carried out at two different experimental conditions similar to variations in [M{sub 0}/I{sub 0}] and [C.L.]. Fourier transform infrared (FTIR) spectroscopy and nuclear magnetic resonance (NMR) spectroscopy confirmed the structure of MWCNT-Eosin Y initiated ROP of C.L. Gel permeation chromatography (GPC), X-ray photoelectron spectroscopy (XPS), UV-visible spectroscopy (UV-vis), scanning electron microscopy (SEM), and transmission electron microscopy (TEM) further characterized the structure. UV-visible spectroscopy determined the binding constant (K), for samples prepared under different [C.L.].

  8. A novel report on Eosin Y functionalized MWCNT as an initiator for ring opening polymerization of ε-caprolactone

    International Nuclear Information System (INIS)

    Chen, Hung-Hsia; Anbarasan, R.; Kuo, Long-Sheng; Chen, Ping-Hei

    2011-01-01

    Research highlights: → In the present investigation, first, we functionalized the MWCNT with Eosin Y dye, for the ring opening polymerization. → The dye functionalized MWCNT acted as an effective initiator which was further confirmed by various analytical techniques. → By this methodology we saved the number of reaction steps, reaction time and also an economically cheaper one. - Abstract: This research conducted ring opening polymerization (ROP) of ε-caprolactone (C.L.) with a novel initiator, namely; Eosin Y functionalized multiwalled carbon nanotube (MWCNT) at 140 deg. C with nitrogen sparge under different concentrations. ROP of C.L. carried out at two different experimental conditions similar to variations in [M 0 /I 0 ] and [C.L.]. Fourier transform infrared (FTIR) spectroscopy and nuclear magnetic resonance (NMR) spectroscopy confirmed the structure of MWCNT-Eosin Y initiated ROP of C.L. Gel permeation chromatography (GPC), X-ray photoelectron spectroscopy (XPS), UV-visible spectroscopy (UV-vis), scanning electron microscopy (SEM), and transmission electron microscopy (TEM) further characterized the structure. UV-visible spectroscopy determined the binding constant (K), for samples prepared under different [C.L.].

  9. Glymphatic stasis at the site of the lamina cribrosa as a potential mechanism underlying open-angle glaucoma.

    Science.gov (United States)

    Wostyn, Peter; Killer, Hanspeter Esriel; De Deyn, Peter Paul

    2017-07-01

    The underlying pathophysiology of primary open-angle glaucoma remains unclear, but the lamina cribrosa seems to be the primary site of injury, and raised intraocular pressure is a major risk factor. In recent years, a decreased intracranial pressure, leading to an abnormally high trans-lamina cribrosa pressure difference, has gained interest as a new risk factor for glaucoma. New research now lends support to the hypothesis that a paravascular transport system is present in the eye analogous to the recently discovered 'glymphatic system' in the brain, which is a functional waste clearance pathway that promotes elimination of interstitial solutes, including β-amyloid, from the brain along paravascular channels. Given that β-amyloid has been reported to increase by chronic elevation of intraocular pressure in glaucomatous animal models and to cause retinal ganglion cell death, the discovery of a paravascular clearance system in the eye may provide powerful new insights into the pathophysiology of primary open-angle glaucoma. In this review, we provide a new conceptual framework for understanding the pathogenesis of primary open-angle glaucoma, present supporting preliminary data from our own post-mortem study and hypothesize that the disease may result from restriction of normal glymphatic flow at the level of the lamina cribrosa owing to a low intracranial pressure and/or a high trans-lamina cribrosa pressure gradient. If confirmed, this viewpoint could offer new perspectives for the development of novel diagnostic and therapeutic strategies for this devastating disorder. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  10. Glymphatic stasis at the site of the lamina cribrosa as a potential mechanism underlying open-angle glaucoma

    NARCIS (Netherlands)

    Wostyn, Peter; Killer, Hanspeter Esriel; De Deyn, Peter Paul

    The underlying pathophysiology of primary open-angle glaucoma remains unclear, but the lamina cribrosa seems to be the primary site of injury, and raised intraocular pressure is a major risk factor. In recent years, a decreased intracranial pressure, leading to an abnormally high trans-lamina

  11. Chronic and Intermittent Angle Closure Caused by In-The-Bag Capsular Tension Ring and Intraocular Lens Dislocation in Patients With Pseudoexfoliation Syndrome.

    Science.gov (United States)

    Bochmann, Frank; Strümer, Jörg

    2017-11-01

    A subluxation or dislocation of the intraocular lens (IOL) is a well-known complication after cataract surgery in patients with pseudoexfoliation syndrome (PEX). Capsular tension rings (CTR) are frequently used to prevent postoperative complications caused by zonular weakness. Here we present a series of 7 cases, 2 with intermittent and 5 with acute angle closure caused by a combination of PEX-associated zonular weakness and a resulting unstable capsular bag-CTR-IOL complex. We describe the typical clinical course with elevated intraocular pressure, myopic shift, and shallowing of the anterior chamber in 7 patients with a new type of secondary angle closure. The diagnostic challenges and treatment options are discussed in detail. In all cases, the mechanism of angle closure identified by ultrasound biomicroscopy was an anterior dislocation of the peripheral iris by the capsular bag-CTR-IOL complex. The IOL was removed together with the capsular bag and the CTR and replaced by an iris-fixated IOL in all cases. We present a new type of secondary angle closure caused by an anterior dislocated capsular bag-CTR-IOL complex. The cause of both, this atypical presentation and the ineffectiveness of the laser peripheral iridotomy is the large diameter CTR. Therefore CTR implantation might also be the source of late postoperative complications. If a secondary angle closure associated with PEX and unstable capsular bag-CTR-IOL complex is encountered, IOL explantation and replacement by an iris-fixated IOL is a simple and effective treatment option.

  12. Ring-like spatial distribution of laser accelerated protons in the ultra-high-contrast TNSA-regime

    Science.gov (United States)

    Becker, G. A.; Tietze, S.; Keppler, S.; Reislöhner, J.; Bin, J. H.; Bock, L.; Brack, F.-E.; Hein, J.; Hellwing, M.; Hilz, P.; Hornung, M.; Kessler, A.; Kraft, S. D.; Kuschel, S.; Liebetrau, H.; Ma, W.; Polz, J.; Schlenvoigt, H.-P.; Schorcht, F.; Schwab, M. B.; Seidel, A.; Zeil, K.; Schramm, U.; Zepf, M.; Schreiber, J.; Rykovanov, S.; Kaluza, M. C.

    2018-05-01

    The spatial distribution of protons accelerated from submicron-thick plastic foil targets using multi-terawatt, frequency-doubled laser pulses with ultra-high temporal contrast has been investigated experimentally. A very stable, ring-like beam profile of the accelerated protons, oriented around the target’s normal direction has been observed. The ring’s opening angle has been found to decrease with increasing foil thicknesses. Two-dimensional particle-in-cell simulations reproduce our results indicating that the ring is formed during the expansion of the proton density distribution into the vacuum as described by the mechanism of target-normal sheath acceleration. Here—in addition to the longitudinal electric fields responsible for the forward acceleration of the protons—a lateral charge separation leads to transverse field components accelerating the protons in the lateral direction.

  13. Multi-Angle Snowflake Camera Value-Added Product

    Energy Technology Data Exchange (ETDEWEB)

    Shkurko, Konstantin [Univ. of Utah, Salt Lake City, UT (United States); Garrett, T. [Univ. of Utah, Salt Lake City, UT (United States); Gaustad, K [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-12-01

    The Multi-Angle Snowflake Camera (MASC) addresses a need for high-resolution multi-angle imaging of hydrometeors in freefall with simultaneous measurement of fallspeed. As illustrated in Figure 1, the MASC consists of three cameras, separated by 36°, each pointing at an identical focal point approximately 10 cm away. Located immediately above each camera, a light aims directly at the center of depth of field for its corresponding camera. The focal point at which the cameras are aimed lies within a ring through which hydrometeors fall. The ring houses a system of near-infrared emitter-detector pairs, arranged in two arrays separated vertically by 32 mm. When hydrometeors pass through the lower array, they simultaneously trigger all cameras and lights. Fallspeed is calculated from the time it takes to traverse the distance between the upper and lower triggering arrays. The trigger electronics filter out ambient light fluctuations associated with varying sunlight and shadows. The microprocessor onboard the MASC controls the camera system and communicates with the personal computer (PC). The image data is sent via FireWire 800 line, and fallspeed (and camera control) is sent via a Universal Serial Bus (USB) line that relies on RS232-over-USB serial conversion. See Table 1 for specific details on the MASC located at the Oliktok Point Mobile Facility on the North Slope of Alaska. The value-added product (VAP) detailed in this documentation analyzes the raw data (Section 2.0) using Python: images rely on OpenCV image processing library and derived aggregated statistics rely on some clever averaging. See Sections 4.1 and 4.2 for more details on what variables are computed.

  14. Five-year extension of a clinical trial comparing the EX-PRESS glaucoma filtration device and trabeculectomy in primary open-angle glaucoma

    NARCIS (Netherlands)

    de Jong, Leo; Lafuma, Antoine; Aguadé, Anne-Sophie; Berdeaux, Gilles

    2011-01-01

    This study compared the efficacy of the EX-PRESS(®) glaucoma filtration device and trabeculectomy in primary open-angle glaucoma up to five years after surgery. Patients from a previously reported randomized, open-label, parallel-arm clinical trial in which 78 patients received either the EX-PRESS

  15. Nitroxide-mediated radical ring-opening copolymerization: chain-end investigation and block copolymer synthesis.

    Science.gov (United States)

    Delplace, Vianney; Harrisson, Simon; Tardy, Antoine; Gigmes, Didier; Guillaneuf, Yohann; Nicolas, Julien

    2014-02-01

    Well-defined, degradable copolymers are successfully prepared by nitroxide-mediated radical ring opening polymerization (NMrROP) of oligo(ethylene glycol) methyl ether methacrylate (OEGMA) or methyl methacrylate (MMA), a small amount of acrylonitrile (AN) and cyclic ketene acetals (CKAs) of different structures. Phosphorous nuclear magnetic resonance allows in-depth chain-end characterization and gives crucial insights into the nature of the copoly-mer terminal sequences and the living chain fractions. By using a small library of P(OEGMA-co-AN-co-CKA) and P(MMA-co-AN-co-CKA) as macroinitiators, chain extensions with styrene are performed to furnish (amphiphilic) block copolymers comprising a degradable segment. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Analysis of axial behavior of three piece oil control ring; Kumiawase oil ring no jikuhoko kyodo no kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    Tateishi, Y; Fujimura, K; Hitosugi, H [Nippon Piston Ring Co. Ltd., Tokyo (Japan)

    1997-10-01

    It is considered that the reduction of oil control ring tension is a major problem in reducing the friction-loss of internal combustion engines. The authors have successfully developed a calculating method for the axial behavior prediction of a three piece type oil control ring as a method used in reduction of lube-oil consumption when lower tension ring is used. By means of the method, the authors found that the effect in reduction of lube-oil consumption was able to be expected by optimizing design parameters of the oil ring, the tension and the seating tab angle of expander-spacer, and the gas pressure on the 3rd land. 3 refs., 14 figs.

  17. Beam-beam collisions and crossing angles in RHIC

    International Nuclear Information System (INIS)

    Peggs, S.

    1999-01-01

    This paper evaluates the strength of head on and parasitic beam-beam collisions in RHIC when the crossing angle is zero. A non-zero crossing angle is not required in normal operation with 120 bunches, thanks to the early separation of the two beams. The RHIC lattice is shown to easily accommodate even conservatively large crossing angles, for example in beam dynamics studies, or in future operational upgrades to as many as 360 bunches per ring. A modest loss in luminosity is incurred when gold ions collide at an angle after 10 hours of storage

  18. Small-angle physics at the intersecting storage rings forty years later

    International Nuclear Information System (INIS)

    Amaldi, Ugo

    2012-01-01

    It is often said that the ISR did not have the detectors needed to discover fundamental phenomena made accessible by its large and new energy range. This is certainly true for ‘high-momentum-transfer physics’, which, since the end of the 1960s, became a main focus of research, but the statement does not apply to the field that is the subject of this paper. In fact, looking back to the results obtained at the ISR by the experiments that were programmed to study ‘small-angle physics’, one can safely say that the detectors were very well suited to the tasks and performed much better than foreseen. As far as the results are concerned, in this particular corner of hadron–hadron physics, new phenomena were discovered, unexpected scaling laws were found and the first detailed studies of that elusive concept, which goes under the name ‘pomeron’, were performed, opening the way to phenomena that we hope will be observed at the LHC. Moreover, some techniques and methods have had a lasting influence: all colliders had and have their Roman pots, and the different methods developed at the ISR for measuring the luminosity are still in use.

  19. Facile solvothermal synthesis of abnormal growth of one-dimensional ZnO nanostructures by ring-opening reaction of polyvinylpyrrolidone

    Energy Technology Data Exchange (ETDEWEB)

    Xu, G., E-mail: gxu@alum.imr.ac.cn; Wang, X.L.; Liu, G.Z.

    2015-02-28

    Graphical abstract: - Highlights: • Facile solvothermal synthesis of ZnO nanostructures in super high alkaline alcoholic condition. • The exact role and chemical transformations of PVP in solvothermal synthesis of ZnO nanostructures was revealed. • Mechanism of abnormal growth of ZnO nanopyramids was proposed based on ring-opening reaction of PVP. - Abstract: Abnormal growth of one-dimensional (1-D) ZnO nanostructures (NSs) have been accomplished with the assistance of polyvinylpyrrolidone (PVP) under a super high alkaline alcoholic solvothermal condition. The products were characterized by transmission electron microscopy (TEM), thermogravimetric analysis (TGA), X-ray diffraction (XRD), Fourier transform infrared (FT-IR) and proton nuclear magnetic resonance ({sup 1}H NMR) spectroscopy. The effect of synthetic conditions, such as reaction temperature and the addition of PVP, on the morphologies of ZnO products were investigated. The results show that PVP molecules had the significant role in the transformation of morphologies of ZnO NSs ranging from nanorods, nanoparticles to pyramids, as well as flower-like assembly features. The possible growth mechanism of ZnO pyramids was proposed based on ring-opening reaction of PVP.

  20. No differences in central corneal thickness between open-angle and pseudoexfoliation glaucoma patients

    Directory of Open Access Journals (Sweden)

    Ayala M

    2017-04-01

    Full Text Available Marcelo Ayala,1 Johanna Karlsson2 1Eye Department, Skaraborg Hospital, Skövde, Sahlgrenska Academy, Gothenburg University and Karolinska Institute, 2Faculty of Medicine, Örebro University, Örebro, Sweden Introduction: Measurements of intraocular pressure (IOP with Goldmann applanation tonometry are affected by central corneal thickness (CCT, as thinner corneas underestimate and thicker corneas overestimate the true IOP value. The literature is controversial regarding CCT values in patients with primary open-angle glaucoma (POAG and exfoliation glaucoma (XFG. The aim of this study was to evaluate CCT in patients with XFG and POAG.Methods: CCT was evaluated with optical coherence tomography (OCT. All participants who were previously diagnosed with either POAG or XFG underwent ophthalmological examinations. Contact lens users and patients with corneal diseases were excluded.Results: Totally, 145 patients were enrolled in this study. The mean CCT was 535±30.4 µm in patients with POAG and was 536±33.7 µm in patients with XFG. The result was not statistically significant (P=0.98. The mean age for all participants was 73.8±7.7 years. The study included totally 61 women and 84 men. The two groups were similar in their demographic data, and mean deviation was the only parameter that differed statistically when comparing POAG with XFG (P=0.02.Conclusion: Our data indicate that patients with XFG do not have thinner corneas than those with POAG, and therefore, CCT can not explain why they progress differently. Keywords: primary open-angle glaucoma, exfoliative glaucoma, central corneal thickness, optical coherence tomography

  1. The increased cost of medical services for people diagnosed with primary open-angle glaucoma: a decision analytic approach.

    Science.gov (United States)

    Kymes, Steven M; Plotzke, Michael R; Li, Jim Z; Nichol, Michael B; Wu, Joanne; Fain, Joel

    2010-07-01

    Glaucoma accounts for more than 11% of all cases of blindness in the United States, but there have been few studies of economic impact. We examine incremental cost of primary open-angle glaucoma considering both visual and nonvisual medical costs over a lifetime of glaucoma. A decision analytic approach taking the payor's perspective with microsimulation estimation. We constructed a Markov model to replicate health events over the remaining lifetime of someone newly diagnosed with glaucoma. Costs of this group were compared with those estimated for a control group without glaucoma. The cost of management of glaucoma (including medications) before the onset of visual impairment was not considered. The model was populated with probability data estimated from Medicare claims data (1999 through 2005). Cost of nonocular medications and nursing home use was estimated from California Medicare claims, and all other costs were estimated from Medicare claims data. We found modest differences in the incidence of comorbid conditions and health service use between people with glaucoma and the control group. Over their expected lifetime, the cost of care for people with primary open-angle glaucoma was higher than that of people without primary open-angle glaucoma by $1688 or approximately $137 per year. Among Medicare beneficiaries, glaucoma diagnosis not found to be associated with significant risk of comorbidities before development of visual impairment. Further study is necessary to consider the impact of glaucoma on quality of life, as well as aspects of physical and visual function not captured in this claims-based analysis. 2010 Elsevier Inc. All rights reserved.

  2. Design and jump phenomenon analysis of an eccentric ring energy harvester

    International Nuclear Information System (INIS)

    Wang, Yu-Jen; Chen, Chung-De

    2013-01-01

    This paper presents the development of a wheel-mounted eccentric ring energy harvester that is driven by centripetal and gravitational forces during wheel rotation. The natural frequency of the eccentric ring matches the wheel rotation frequency at any car speed because its character length is designed equal to the wheel radius. Consequently, the eccentric ring oscillates with a relatively large swing angle at the wheel speed to generate high levels of power. The nonlinear dynamic behavior of the eccentric ring is investigated to ensure that the proposed design produces steady swing angles, especially at high wheel speeds. Herein, the jump phenomenon of the dynamic motion of the eccentric ring is analyzed by using the Duffing equation and the linearization process. The discriminant value obtained from the analysis confirms that no jump phenomenon occurs at all wheel speeds if the eccentric ring is properly designed. In the experiment, the eccentric ring is integrated with magnets and a coil set to generate 318–442 μW at constant wheel speeds between 300 and 500 rpm. This shows that the proposed device is a potential power source for low-power wheel-mounted electronics, such as pressure sensors, accelerometers, and thermometers. (paper)

  3. Design and jump phenomenon analysis of an eccentric ring energy harvester

    Science.gov (United States)

    Wang, Yu-Jen; Chen, Chung-De

    2013-10-01

    This paper presents the development of a wheel-mounted eccentric ring energy harvester that is driven by centripetal and gravitational forces during wheel rotation. The natural frequency of the eccentric ring matches the wheel rotation frequency at any car speed because its character length is designed equal to the wheel radius. Consequently, the eccentric ring oscillates with a relatively large swing angle at the wheel speed to generate high levels of power. The nonlinear dynamic behavior of the eccentric ring is investigated to ensure that the proposed design produces steady swing angles, especially at high wheel speeds. Herein, the jump phenomenon of the dynamic motion of the eccentric ring is analyzed by using the Duffing equation and the linearization process. The discriminant value obtained from the analysis confirms that no jump phenomenon occurs at all wheel speeds if the eccentric ring is properly designed. In the experiment, the eccentric ring is integrated with magnets and a coil set to generate 318-442 μW at constant wheel speeds between 300 and 500 rpm. This shows that the proposed device is a potential power source for low-power wheel-mounted electronics, such as pressure sensors, accelerometers, and thermometers.

  4. Association of lens vault with narrow angles among different ethnic groups.

    Science.gov (United States)

    Lee, Roland Y; Huang, Guofu; Cui, Qi N; He, Mingguang; Porco, Travis C; Lin, Shan C

    2012-06-01

    To compare lens vault between open-angle and narrow-angle eyes in African-, Caucasian-, Hispanic-, Chinese- and Filipino-Americans. In this prospective study, 436 patients with open angle and narrow angle based on the Shaffer gonioscopic grading classification underwent anterior-segment optical coherence tomography. The Zhongshan Angle Assessment Program was used to calculate lens vault. The narrow-angle group included 32 Chinese-Americans, 22 Filipino-Americans, 26 African-Americans, 24 Hispanic-Americans and 73 Caucasian-Americans. The open-angle group included 56 Chinese-Americans, 29 Filipino-Americans, 45 African-Americans, 27 Hispanic-Americans and 102 Caucasian-Americans. Linear mixed effect regression models, accounting for the use of both eyes and adjusting for age, sex, pupil diameter and spherical equivalent, were used to test for the ethnicity and angle coefficients. Tukey's multiple comparison test was used for pairwise comparisons among the open-angle racial groups. Significant difference in lens vault was found among the open-angle racial groups (P = 0.022). For the open-angle patients, mean values for the lens vault measurements were 265 ± 288 µm for Chinese-Americans, 431 ± 248 µm for Caucasian-Americans, 302 ± 213 µm for Filipino-Americans, 304 ± 263 µm for Hispanic-Americans and 200 ± 237 µm for African-Americans. Using Tukey's multiple comparison for pairwise comparisons among the open-angle racial groups, a significant difference was found between African-American and Caucasian-Americans groups (P values for the rest of the pairwise comparisons were not statistically significant. No significant difference was found among the narrow-angle racial groups (P = 0.14). Comparison between the open angle and narrow angle within each racial group revealed significant difference for all racial groups (P < 0.05). Among all the ethnicities included in this study, narrow-angle eyes have greater lens vault compared to open-angle

  5. Looking For Thermal IR Polarization In Saturn's Rings With Cassini/CIRS

    Science.gov (United States)

    Edgington, Scott G.; Spilker, L. J.; Jennings, D. E.; Altobelli, N.; Pilorz, S. H.; Pearl, J. C.; Leyrat, C.; CIRS Team

    2007-10-01

    The Cassini Composite Infrared Spectrometer (CIRS) FP1 channel is a polarizing interferometer covering the spectral range from 10 to 600 cm-1. By rotating the instrument about its optical axis, it is possible to measure the IR polarization of target objects over that spectral range. This requires the FP1 footprint on the rings, the emission angle, and the phase angle to be fairly constant for the duration of the observation. With these constraints, we turned two composition observations, both allocated long periods of time for sitting-and-staring, into polarization observations. The time was divided equally amongst observations of the A, B, and C rings, with one observation taking place on the lit side and the other on the unlit side. We chose relative rotations of 0, 30, and 60 degrees (future observations will use 0, 45, 90, and 135 degree rotations). For each ring, we will determine the Stokes Vector (I, Q, U, V) and the degree of polarization, (Q+U+V)/I. We will also examine the degree to which the temperature and emissivity varies with the orientation of the field of view. One of the observation takes place at low phase angles. At low phase angles, the filling factor of the C-Ring has been shown to increase steeply with decreasing spacecraft elevation (Altobelli, et al., 2007). We will determine the limitations of this physical effect on the determination of the polarization of the C-ring. Successful measurements should provide information on the microscopic roughness of ring particles. We will report on results of these observations. For a similar analysis pertaining to Iapetus' surface, see J. C. Pearl, et al. (this meeting). The research described in this paper was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration.

  6. Long-term efficacy and safety of ExPress implantation for treatment of open angle glaucoma

    OpenAIRE

    Lee, Geun Young; Lee, Chong Eun; Lee, Kyoo Won; Seo, Sam

    2017-01-01

    AIM: To compare the long-term efficacy and safety of ExPress implantation and standard trabeculectomy in patients with primary open angle glaucoma (POAG). METHODS: In this retrospective study, we compared 17 eyes treated by ExPress implantation with 23 eyes treated by trabeculectomy. Efficacy was assessed according to the relevant intraocular pressure (IOP) values and success rates during the first year of follow-up. Postoperative corneal endothelial cell loss was also compared. RESULTS...

  7. Hypothyroidism as a risk factor for open angle glaucoma: A systematic review and meta-analysis

    OpenAIRE

    Wang, Shiming; Liu, Yue; Zheng, Guangying

    2017-01-01

    Purpose The relationship between hypothyroidism and primary open angle glaucoma (POAG) has attracted intense interest recently, but the reported results have been controversial. This meta-analysis was carried out to determine the association between hypothyroidism and POAG. Methods The literature was identified from three databases (Web of Science, Embase, and PubMed). The meta-analyses were performed using random-effects models, with results reported as adjusted odds ratios (ORs) with 95% co...

  8. Novel Zinc-Catalytic Systems for Ring-Opening Polymerization of ε-Caprolactone

    Directory of Open Access Journals (Sweden)

    Karolina Żółtowska

    2015-02-01

    Full Text Available Polycaprolactone (PCL is a biodegradable synthetic polymer that is currently widely used in many pharmaceutical and medical applications. In this paper we describe the coordination ring-opening polymerization of ε-caprolactone in the presence of two newly synthesized catalytic systems: diethylzinc/gallic acid and diethylzinc/propyl gallate. The chemical structures of the obtained PCLs were characterized by 1H- or 13C-NMR, FTIR spectroscopy and MALDI TOF mass spectrometry. The average molecular weight of the resulting polyesters was analysed by gel permeation chromatography and a viscosity method. The effects of temperature, reaction time and type of catalytic system on the polymerization process were examined. Linear PCLs with defined average molecular weight were successfully obtained. Importantly, in some cases the presence of macrocyclic products was not observed during the polymerization process. This study provides an effective method for the synthesis of biodegradable polyesters for medical and pharmaceutical applications due to the fact that gallic acid/propyl gallate are commonly used in the pharmaceutical industry.

  9. Establishing Age-Adjusted Reference Ranges for Iris-Related Parameters in Open Angle Eyes with Anterior Segment Optical Coherence Tomography.

    Directory of Open Access Journals (Sweden)

    Jeffrey R Peterson

    Full Text Available Define criteria for iris-related parameters in an adult open angle population as measured with swept source Fourier domain anterior segment optical coherence tomography (ASOCT.Ninety-eight eyes of 98 participants with open angles were included and stratified into 5 age groups (18-35, 36-45, 46-55, 56-65, and 66-79 years. ASOCT scans with 3D mode angle analysis were taken with the CASIA SS-1000 (Tomey Corporation, Nagoya, Japan and analyzed using the Anterior Chamber Analysis and Interpretation software. Anterior iris surface length (AISL, length of scleral spur landmark (SSL to pupillary margin (SSL-to-PM, iris contour ratio (ICR = AISL/SSL-to-PM, pupil radius, radius of iris centroid (RICe, and iris volume were measured. Outcome variables were summarized for all eyes and age groups, and mean values among age groups were compared using one-way analysis of variance. Stepwise regression analysis was used to investigate demographic and ocular characteristic factors that affected each iris-related parameter.Mean (±SD values were 2.24 mm (±0.46, 4.06 mm (±0.27, 3.65 mm (±0.48, 4.16 mm (±0.47, 1.14 (±0.04, 1.51 mm2 (±0.23, and 38.42 μL (±4.91 for pupillary radius, RICe, SSL-to-PM, AISL, ICR, iris cross-sectional area, and iris volume, respectively. Both pupillary radius (P = 0.002 and RICe (P = 0.027 decreased with age, while SSL-to-PM (P = 0.002 and AISL increased with age (P = 0.001. ICR (P = 0.54 and iris volume (P = 0.49 were not affected by age.This study establishes reference values for iris-related parameters in an adult open angle population, which will be useful for future studies examining the role of iris changes in pathologic states.

  10. Confinement and stability of crystalline beams in storage rings

    International Nuclear Information System (INIS)

    Haffmans, A.F.

    1995-01-01

    We present a fully analytical approach to the study of the confinement and stability of open-quote open-quote Crystalline Beams close-quote close-quote in storage rings, in terms of such fundamental accelerator concepts as tune shift and stopband. We consider a open-quote open-quote Crystalline Beam close-quote close-quote consisting of substrings, arranged symmetrically around the reference trajectory, and we examine the motion of a slightly perturbed test particle on one of them. Our approach quite naturally leads to the conclusion, that (a) storage rings need to be operated below the transition energy, and (b) the open-quote open-quote Crystalline Beam close-quote close-quote has the same periodicity as the storage ring. Each open-quote open-quote Crystalline Beam close-quote close-quote has an upper and lower limit of the spacing between the ions. The upper limit is determined by condition (b), and the lower limit is set by the stability of the test particle motion around the equilibrium. copyright 1995 American Institute of Physics

  11. [Dry eye syndrome in patients with primary open-angle glaucoma].

    Science.gov (United States)

    Boyko, E V; Simakova, I L; Yakushev, D Yu; Ignat'ev, S A; Alekseev, I B; Mel'nikova, N V; Alyab'ev, M V; Mal'tsev, D S

    2015-01-01

    to determine the frequency and severity of dry eye syndrome (DES) in primary open-angle glaucoma (POAG) patients that are newly diagnosed or already receiving beta blocker instillation therapy. A total of 127 patients (190 eyes) with POAG were divided into two groups. Group 1 included 55 newly diagnosed patients (88 eyes), group 2-72 POAG patients (102 eyes) instilling timolol 0.5% twice daily into the affected eye. The control group included 20 patients (40 eyes) aged 60-88 years (73.6 ± 9.2 years on average) with early age-related cataract. DES was found in 69 POAG patients (79%) who was just starting their topical hypotensive therapy and 85 of those (84%) under treatment (p = 0.39). One should take into account when prescribing ocular hypotensive therapy that newly diagnosed POAG patients usually already suffer from a dry eye. The use of topical beta blockers that contain preservatives exacerbates dry eye signs and symptoms in these patients.

  12. Using Digital Technology to See Angles from Different Angles. Part 2: Openings and Turns

    Science.gov (United States)

    Host, Erin; Baynham, Emily; McMaster, Heather

    2015-01-01

    Ever wondered how to use technology to teach angles? This article follows on from an earlier article published last year, providing a range of ideas for integrating technology and concrete materials with the teaching of angle concepts. The authors also provide a comprehensive list of free online games and learning objects that can be used to teach…

  13. Ring opening of 2-aza-3-borabicyclo[2.2.0]hex-5-ene, the Dewar form of 1,2-dihydro-1,2-azaborine: stepwise versus concerted mechanisms

    Directory of Open Access Journals (Sweden)

    Holger F. Bettinger

    2013-04-01

    Full Text Available The ring opening of the Dewar form of 1,2-dihydro-1,2-azaborine, 2-aza-3-borabicyclo[2.2.0]hex-5-ene (3 is investigated by theoretical methods by using multiconfiguration SCF (CASSCF and coupled cluster theory [CCSD(T] with basis sets up to polarised quadruple-zeta quality. The title compound was previously reported to form photochemically in cryogenic noble gas matrices from 1,2-dihydro-1,2-azaborine (4. Four reaction paths for the thermal ring opening of 3 to 4 could be identified. These are the conventional disrotatory and conrotatory electrocyclic ring-opening pathways where the BN unit is only a bystander. Two more favourable paths are stepwise and involve 1,3-boron–carbon interactions. The lowest energy barrier for the isomerisation reaction, 22 kcal mol−1, should be high enough for an experimental observation in solution. However, in solution the dimerisation of 3 is computed to have a very low barrier (3 kcal mol−1, and thus 3 is expected to be a short-lived reactive intermediate.

  14. Lactic Acid Yield Using Different Bacterial Strains, Its Purification, and Polymerization through Ring-Opening Reactions

    Directory of Open Access Journals (Sweden)

    F. G. Orozco

    2014-01-01

    Full Text Available Laboratory-scale anaerobic fermentation was performed to obtain lactic acid from lactose, using five lactic acid bacteria: Lactococcus lactis, Lactobacillus bulgaricus, L. delbrueckii, L. plantarum, and L. delbrueckii lactis. A yield of 0.99 g lactic acid/g lactose was obtained with L. delbrueckii, from which a final concentration of 80.95 g/L aqueous solution was obtained through microfiltration, nanofiltration, and inverse osmosis membranes. The lactic acid was polymerized by means of ring-opening reactions (ROP to obtain poly-DL-lactic acid (PDLLA, with a viscosity average molecular weight (Mv of 19,264 g/mol.

  15. Metal-​based catalysts for controlled ring-​opening polymerization of macrolactones : high molecular weight and well-​defined copolymer architectures

    NARCIS (Netherlands)

    Bouyahyi, M.; Duchateau, R.

    2014-01-01

    This contribution describes our recent results regarding the metal-¿catalyzed ring-¿opening polymn. of pentadecalactone and its copolymn. with e-¿caprolactone involving single-¿site metal complexes based on aluminum, zinc, and calcium. Under the right conditions (i.e., monomer concn., catalyst type,

  16. Synthesis and Ring-Opening Metathesis Polymerization of Second-Generation Dendronized Poly(ether Monomers Initiated by Ruthenium Carbenes

    Directory of Open Access Journals (Sweden)

    Guzmán Pablo E.

    2016-03-01

    Full Text Available The Ring-Opening Metathesis Polymerization (ROMP of second-generation dendronized monomers is described. Using the highly active and fast-initiating third-generation ruthenium complex [(H2IMes(pyr2Cl2RuCHPh], moderate to high molecular weight polymers (430-2230 kDa are efficiently synthesized with low dispersities (Ð = 1.01-1.17. This study highlights the power of the metathesis approach toward polymer synthesis in a context where monomer structure can significantly impede polymerization.

  17. In situ crosslinking of surface-initiated ring opening metathesis polymerization of polynorbornene for improved stability.

    Science.gov (United States)

    Fursule, Ishan A; Abtahi, Ashkan; Watkins, Charles B; Graham, Kenneth R; Berron, Brad J

    2018-01-15

    In situ crosslinking is expected to increase the solvent stability of coatings formed by surface-initiated ring opening metathesis polymerization (SI ROMP). Solvent-associated degradation limits the utility of SI ROMP coatings. SI ROMP coatings have a unique capacity for post-functionalization through reaction of the unsaturated site on the polymer backbone. Any post-reaction scheme which requires a liquid solvent has the potential to degrade the coating and lower the thickness of the resulting film. We designed a macromolecular crosslinking group based on PEG dinorbornene. The PEG length is tailored to the expected mean chain to chain distance during surface-initiated polymerization. This crosslinking macromer is randomly copolymerized with norbornene through SI ROMP on a gold coated substrate. The solvent stability of polynorbornene coatings with and without PEG dinorbornene is quantitatively determined, and the mechanism of degradation is further supported through XPS and AFM analyses. The addition of the 0.25mol% PEG dinorbornene significantly increases the solvent stability of the SI ROMP coatings. The crosslinker presence in the more stable films is supported with observable PEG absorbances by FTIR and an increase in contact angle hysteresis when compared to non-crosslinked coatings. The oxidation of the SI ROMP coatings is supported by the observation of carbonyl oxygen in the polynorbornene coatings. The rapid loss of the non-crosslinked SI ROMP coating corresponds to nanoscale pitting across the surface and micron-scale regions of widespread film loss. The crosslinked coatings have uniform nanoscale pitting, but the crosslinked films show no evidence of micron-scale film damage. In all, the incorporation of minimal crosslinking content is a simple strategy for improving the solvent stability of SI ROMP coatings. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Bosonic and fermionic dipoles on a ring

    DEFF Research Database (Denmark)

    Zöllner, Sascha; Pethick, C. J.; Bruun, Georg Morten

    2011-01-01

    We show that dipolar bosons and fermions confined in a quasi-one-dimensional ring trap exhibit a rich variety of states because their interaction is inhomogeneous. For purely repulsive interactions, with increasing strength of the dipolar coupling there is a crossover from a gaslike state...... to an inhomogeneous crystal-like one. For small enough angles between the dipoles and the plane of the ring, there are regions with attractive interactions, and clustered states can form....

  19. [Psychosomatic symptoms in somatic diseases - open-angle glaucoma for example].

    Science.gov (United States)

    Emmerich, G M

    2010-08-01

    Psychological aspects exist in somatic diseases like tumours and even fractures, not only in the beginning but also in the management of disease. Somatic diseases give rise to signs of a special constellation of life and management of these diseases is important for the psychological constellation of the individual. Studies on open-angle glaucoma have shown that many patients suffering from this disease are anxious, hypochondric, perfectionist and emotional instable. Chronic diseases are demanding processes of flexibility and defense, and define how the individual can deal with the diseases and what place in life the disease will occupy in the future. In the holistic view of medicine even psychological conflicts should be treated. In many situations, these conflicts are not consciously experienced by the individual. Therapeutically, 2 different tools can be used: symbolic stories can bring forces to manage the conflict and to solve the conflict (2 examples in the text). The method of positive psychotherapy describes the reasons for psychosomatic diseases in three parts: psychosomatic in the traditional understanding, in further and comprehensive understanding. Especially the psychosomatic effects in comprehensive understanding are embedded in the individual's sociocultural environment and provide tips on reasons for the diseases in those parts of life. The "positive balance model" gives an example of life-management and conflict-therapy. In ophthalmology, fear is often more important for the patient than pain. To avoid this, the patients develop techniques to deny, to cover or to suppress the fear. In the article questions are presented like those the ophthalmologist should be able to ask patients in the office concerning open-angle glaucoma. Tips for the therapy and management for neurotic stress are offered and some special anamnestic questions for the ophthalmologist are presented. Unsolved conflicts and denied desires as neurotic symptoms can be focused in

  20. Novel and known MYOC exon 3 mutations in an admixed Peruvian primary open-angle glaucoma population

    OpenAIRE

    Mendoza Reinoso, Veronica; Patil, Teja S.; Guevara Fujita, María Luisa; Fernández, Silvia; Vargas, Enrique; Castillo Herrera, Wilder; Perez Grossmann, Rodolfo; Lizaraso Caparó, Frank; Richards, Julia E.; Fujita, Ricardo

    2012-01-01

    Purpose: The aim of this study was to characterize a representative sample of the Peruvian population suffering openangle glaucoma (OAG) with respect to the myocilin gene (MYOC) mutations, glaucoma phenotype, and ancestry for future glaucoma risk assessment. Methods: DNA samples from 414 unrelated Peruvian subjects, including 205 open-angle glaucoma cases (10 juvenile glaucoma [JOAG], 19 normal-tension glaucoma [NTG], and 176 POAG) and 209 randomly sampled controls, were screen...

  1. Highly Active N,O Zinc Guanidine Catalysts for the Ring-Opening Polymerization of Lactide.

    Science.gov (United States)

    Schäfer, Pascal M; Fuchs, Martin; Ohligschläger, Andreas; Rittinghaus, Ruth; McKeown, Paul; Akin, Enver; Schmidt, Maximilian; Hoffmann, Alexander; Liauw, Marcel A; Jones, Matthew D; Herres-Pawlis, Sonja

    2017-09-22

    New zinc guanidine complexes with N,O donor functionalities were prepared, characterized by X-Ray crystallography, and examined for their catalytic activity in the solvent-free ring-opening polymerization (ROP) of technical-grade rac-lactide at 150 °C. All complexes showed a high activity. The fastest complex [ZnCl 2 (DMEGasme)] (C1) produced colorless poly(lactide) (PLA) after 90 min with a conversion of 52 % and high molar masses (M w =69 100, polydispersity=1.4). The complexes were tested with different monomer-to-initiator ratios to determine the rate constant k p . Furthermore, a polymerization with the most active complex C1 was monitored by in situ Raman spectroscopy. Overall, conversion of up to 90 % can be obtained. End-group analysis was performed to clarify the mechanism. All four complexes combine robustness against impurities in the lactide with high polymerization rates, and they represent the fastest robust lactide ROP catalysts to date, opening new avenues to a sustainable ROP catalyst family for industrial use. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Progressive Decrease of Peripapillary Angioflow Vessel Density During Structural and Visual Field Progression in Early Primary Open-angle Glaucoma.

    Science.gov (United States)

    Holló, Gábor

    2017-07-01

    To present a case of early primary open-angle glaucoma in which retinal nerve fiber layer thickness (RNFLT), ganglion cell complex (GCC), and visual field progression were accompanied with significant progression of peripapillary angioflow vessel density (PAFD) measured with optical coherence tomographic angiography. A 68-year-old female patient who was under topical intraocular pressure (IOP) lowering medication for 20 years for ocular hypertension of the right and preperimetric primary open-angle glaucoma of the left eye (with reproducible inferotemporal and superotemporal neuroretinal rim and RNFL loss) was prospectively imaged with the AngioVue OCT for RNFLT, GCC thickness, and PAFD, and investigated with the Octopus Normal G2 visual field test on the same days at 6-month intervals for 18 months, while the IOP of the left eye escaped from control. IOP of the left eye fluctuated between 14 and 30 mm Hg in the study period. RNFLT, GCC thickness, and peripapillary PAFD all decreased significantly (linear regression analysis, P=0.030, 0.040, and 0.020, respectively), and a significant 2.1 dB/y progression was seen for a superior visual field cluster. The RNFLT, peripapillary PAFD, and visual field of the right eye remained normal and unchanged. In our case IOP elevation, glaucomatous visual field conversion, and structural progression were accompanied with significant progressive decrease of peripapillary PAFD. The simultaneous thinning of RNFLT and GCC and decrease of peripapillary PAFD suggest that PAFD may potentially be an additional indicator of early progression in primary open-angle glaucoma.

  3. Identification and functional characterization of a novel MYOC mutation in two primary open angle glaucoma families from The Netherlands.

    NARCIS (Netherlands)

    Hogewind, B.F.T.; Gaplovska-Kysela, K.; Theelen, T.; Cremers, F.P.M.; Yam, G.H.; Hoyng, C.B.; Mukhopadhyay, A.

    2007-01-01

    PURPOSE: Glaucoma is the second most prevalent cause of blindness worldwide, projected to affect more than 60 million people by 2010, 75% of which represents primary open angle glaucoma (POAG). Of the three genes, namely, Myocilin (MYOC), Optineurin (OPTN), and WD repeat-containing protein 36

  4. Probing Stereoselectivity in Ring-Opening Metathesis Polymerization Mediated by Cyclometalated Ruthenium-Based Catalysts: A Combined Experimental and Computational Study

    OpenAIRE

    Rosebrugh, L. E.; Ahmed, T. S.; Marx, V. M.; Hartung, J.; Liu, P.; López, J. G.; Houk, K. N.; Grubbs, R. H.

    2016-01-01

    The microstructures of polymers produced by ring-opening metathesis polymerization (ROMP) with cyclometalated Ru-carbene metathesis catalysts were investigated. A strong bias for a cis,syndiotactic microstructure with minimal head-to-tail bias was observed. In instances where trans errors were introduced, it was determined that these regions were also syndiotactic. Furthermore, hypothetical reaction intermediates and transition structures were analyzed computationally. Combined experimental a...

  5. Prospective case series on trabecular-iris angle status after an acute episode of phacomorphic angle closure

    Directory of Open Access Journals (Sweden)

    Jacky Lee

    2013-02-01

    Full Text Available AIM:To investigate the trabecular-iris angle with ultrasound biomicroscopy (UBM post cataract extraction after an acute attack of phacomorphic angle closure.METHODS: This prospective study involved 10 cases of phacomorphic angle closure that underwent cataract extraction and intraocular lens insertion after intraocular pressure (IOP lowering. Apart from visual acuity and IOP, the trabecular-iris angle was measured by gonioscopy and UBM at 3 months post attack.RESULTS: In 10 consecutive cases of acute phacomorphic angle closure from December 2009 to December 2010, gonioscopic findings showed peripheral anterior synechiae (PAS ≤ 90° in 30% of phacomorphic patients and a mean Shaffer grading of (3.1±1.0. UBM showed a mean angle of (37.1°±4.5° in the phacomorphic eye with the temporal quadrant being the most opened and (37.1°±8.0° in the contralateral uninvolved eye. The mean time from consultation to cataract extraction was (1.4±0.7 days and the mean total duration of phacomorphic angle closure was (3.6±2.8 days but there was no correlation to the degree of angle closure on UBM (Spearman correlation P=0.7. The presenting mean IOP was (50.5±7.4 mmHg and the mean IOP at 3 months was (10.5±3.4 mmHg but there were no correlations with the degree of angle closure (Spearman correlations P=0.9.CONCLUSION:An open trabecular-iris angle and normal IOP can be achieved after an acute attack of phacomorphic angle closure if cataract extraction is performed within 1 day - 2 days after IOP control. Gonioscopic findings were in agreement with UBM, which provided a more specific and object angle measurement. The superior angle is relatively more narrowed compared to the other quadrants. All contralateral eyes in this series had open angles.

  6. The impact of changing solar screen rotation angle and its opening aspect ratios on Daylight Availability in residential desert buildings

    KAUST Repository

    Sherif, Ahmed H.; Sabry, Hanan M.; Gadelhak, Mahmoud I.

    2012-01-01

    usually used to diffuse and prevent direct solar penetration into spaces. This paper investigates the impact of changing solar screen axial rotation angle and screen opening aspect ratio on daylighting performance in a typical residential living room space

  7. Synthesis of 2-arylidenebenzocycloalkanones containing N-donor heterocyclic rings

    Energy Technology Data Exchange (ETDEWEB)

    Sun, S.-W., E-mail: sunsw0819@163.com [Yuncheng University, Department of Applied Chemistry (China); Zhang, X., E-mail: zhangx@hit.edu.cn [Harbin Institute of Technology, Academy of Fundamental and Interdisciplinary Science (China); Wang, G.-F. [Yuncheng University, Department of Applied Chemistry (China)

    2016-12-15

    A series of 2-arylidenebenzocycloalkanones containing heterocyclic rings 1–8 were prepared and characterized by IR, {sup 1}H NMR and elemental analyses. X-ray diffraction study of 6 reveals that the cyclohexyl ring of the 3,4-dihydronaphthalen-1(2H)-one adopts a chair conformation with a maximum deviation of 0.547(3) Å and makes dihedral angles of 52.24(17)° and 11.23(16)°, respectively, with the benzene plane and the mean plane of the benzimidazole ring.

  8. Anterior Segment Imaging Predicts Incident Gonioscopic Angle Closure.

    Science.gov (United States)

    Baskaran, Mani; Iyer, Jayant V; Narayanaswamy, Arun K; He, Yingke; Sakata, Lisandro M; Wu, Renyi; Liu, Dianna; Nongpiur, Monisha E; Friedman, David S; Aung, Tin

    2015-12-01

    To investigate the incidence of gonioscopic angle closure after 4 years in subjects with gonioscopically open angles but varying degrees of angle closure detected on anterior segment optical coherence tomography (AS OCT; Visante; Carl Zeiss Meditec, Dublin, CA) at baseline. Prospective, observational study. Three hundred forty-two subjects, mostly Chinese, 50 years of age or older, were recruited, of whom 65 were controls with open angles on gonioscopy and AS OCT at baseline, and 277 were cases with baseline open angles on gonioscopy but closed angles (1-4 quadrants) on AS OCT scans. All subjects underwent gonioscopy and AS OCT at baseline (horizontal and vertical single scans) and after 4 years. The examiner performing gonioscopy was masked to the baseline and AS OCT data. Angle closure in a quadrant was defined as nonvisibility of the posterior trabecular meshwork by gonioscopy and visible iridotrabecular contact beyond the scleral spur in AS OCT scans. Gonioscopic angle closure in 2 or 3 quadrants after 4 years. There were no statistically significant differences in age, ethnicity, or gender between cases and controls. None of the control subjects demonstrated gonioscopic angle closure after 4 years. Forty-eight of the 277 subjects (17.3%; 95% confidence interval [CI], 12.8-23; P < 0.0001) with at least 1 quadrant of angle closure on AS OCT at baseline demonstrated gonioscopic angle closure in 2 or more quadrants, whereas 28 subjects (10.1%; 95% CI, 6.7-14.6; P < 0.004) demonstrated gonioscopic angle closure in 3 or more quadrants after 4 years. Individuals with more quadrants of angle closure on baseline AS OCT scans had a greater likelihood of gonioscopic angle closure developing after 4 years (P < 0.0001, chi-square test for trend for both definitions of angle closure). Anterior segment OCT imaging at baseline predicts incident gonioscopic angle closure after 4 years among subjects who have gonioscopically open angles and iridotrabecular contact on AS OCT at

  9. The Role of Low-frequency TRANS-orbital Magnetic Stimulation in Normalization of Intraocular Pressure in Patients with Primary Open-angle Glaucoma

    Directory of Open Access Journals (Sweden)

    I. A. Makarov

    2016-01-01

    Full Text Available Purpose. Assessment of the effectiveness of low-frequency magnetic therapy on the dynamics of intraocular pressure in the treatment of primary and uncompensated medical means of open-angle glaucoma. Patients and Methods. 46 patients with uncompensated open-angle glaucoma. The first group: 24 patients (42 eyes with open-angle glaucoma (I, II, III stages during 2–13 years. The second group: 22 patients (22 eyes with newly diagnosed elevated intraocular pressure in one eye. The age of patients ranged from 43 to 59 years. Treatment included antiglaucoma hypotensive eye drops and TRANS-orbital magnetic stimulation on the domestic device“Polus-2”. Results. Intraocular pressure before treatment ranged from 25 to 32 mm Hg. (average of 28.9±1.4 mm Hg. in the first group . After magnetic stimulation IOP decreased within 2–5 days in all patients to 18 to 21 mm Hg (average of 17.9±1.1 mm Hg, reaching values “pressure goal.” Second group: in the primary treatment in patients IOP was 28–39 mm Hg (average of 32.6±1.8 mm Hg on one of the eyes. IOP decreased to 16–21 mm Hg in the period from 3 to 9 days in all patients of study group after daily magnetic stimulation and instillation of xalatan and timolol. In the control subgroup of patients with uncompensated openangle glaucoma loweringof the IOP to “pressure goal,” noted only in 7 patients (70,0% 11–14 days after instillation of anti-hypertensive glaucoma eye drops only. Conclusion. Low-frequency TRANS-orbital magnetic stimulation in enhanced hypotensive effect antiglaucomatous eye drops and makes it easier to achieve compensation of IOP to values “pressure goals” in patients with uncompensated open-angle glaucoma. The marked dependence of the efficiency of reduction of IOP from biotropic parameters of the magnetic field. The pulsed mode with a higher amplitude value of the magnetic induction has a more pronounced effect and makes it easier to achieve the reduction of IOP.

  10. Planar Hall ring sensor for ultra-low magnetic moment sensing

    DEFF Research Database (Denmark)

    Hung, Tran Quang; Terki, Ferial; Kamara, Souleymanne

    2015-01-01

    The field sensitivity of a planar Hall effect (PHE) micro-ring type biosensor has been investigated as a function of magnetizing angle of the sensor material, for the sensing of low magnetic moment superparamagnetic labels. The field sensitivity is maximal at a magnetizing angle of α = 20°. At th...

  11. Ring-opening polymerization of 19-electron [2]cobaltocenophanes: a route to high-molecular-weight, water-soluble polycobaltocenium polyelectrolytes.

    Science.gov (United States)

    Mayer, Ulrich F J; Gilroy, Joe B; O'Hare, Dermot; Manners, Ian

    2009-08-05

    Water-soluble, high-molecular-weight polycobaltocenium polyelectrolytes have been prepared by ring-opening polymerization (ROP) techniques. Anionic polymerization of a strained 19-electron dicarba[2]cobaltocenophane followed by oxidation in the presence of ammonium chloride resulted in the formation of oligomers with up to nine repeat units. Thermal ROP of dicarba[2]cobaltocenophane followed by oxidation in the presence of ammonium nitrate resulted in the formation of high-molecular-weight polycobaltocenium nitrate, a redox-active cobalt-containing polyelectrolyte.

  12. [Effects of nootropic agents on visual functions and lacrimal antioxidative activity in patients with primary open-angle glaucoma].

    Science.gov (United States)

    Davydova, N G; Kuznetsova, T P; Borisova, S A; Abdulkadyrova, M Zh

    2006-01-01

    The paper presents the results of an investigation of the effect of the nootropic agents pantogam and nooclerine on visual functions in patients with primary open-angle glaucoma. These agents have been found to have a beneficial effect on the functional activity of the retina and optic nerve, light sensitivity, hemo- and hydrodynamics of the eye.

  13. Phosphazene-promoted metal-free ring-opening polymerization of ethylene oxide initiated by carboxylic acid

    KAUST Repository

    Zhao, Junpeng

    2014-03-11

    The effectiveness of carboxylic acid as initiator for the anionic ring-opening polymerization of ethylene oxide was investigated with a strong phosphazene base (t-BuP4) used as promoter. Kinetic study showed an induction period, i.e., transformation of carboxylic acid to hydroxyl ester, followed by slow chain growth together with simultaneous and fast end-group transesterification, which led to poly(ethylene oxide) (PEO) consisting of monoester (monohydroxyl), diester, and dihydroxyl species. An appropriate t-BuP4/acid ratio was proven to be essential to achieve better control over the polymerization and low dispersity of PEO. This work provides important information and enriches the toolbox for macromolecular and biomolecular engineering with protic initiating sites. © 2014 American Chemical Society.

  14. On Radiative Factors in Planetary Rings: New Insight Derived from Cassini CIRS Observations at Saturn Equinox

    Science.gov (United States)

    Brooks, S. M.; Spilker, L. J.; Pilorz, S.; Edgington, S. G.; Deau, E.; Morishima, R.

    2012-12-01

    Since arriving at Saturn in 2004, Cassini's Composite Infrared Spectrometer has recorded tens of millions of spectra of Saturn's rings (personal communication, M. Segura). CIRS records far infrared radiation (16.7-1000 microns) at focal plane 1 (FP1). Thermal emission from Saturn's rings peaks at FP1 wavelengths. CIRS spectra are well characterized as blackbody emission at an effective temperature Te, multiplied by a scalar factor related to ring emissivity (Spilker et al. [2005, 2006]). CIRS can therefore characterize the rings' temperature and study the thermal environment to which the ring particles are subject. We focus on CIRS data from the 2009 Saturnian equinox. As the Sun's disk crossed the ring plane, CIRS obtained several radial scans of the rings at a variety of phase angles, local hour angles and distances. With the Sun's rays striking the rings at an incidence angle of zero, solar heating is virtually absent, and thermal radiation from Saturn and sunlight reflected by Saturn dominate the thermal environment. These observations appear to present a paradox. Equinox data show that the flux of thermal energy radiated by the rings can even exceed the energy incident upon them as prescribed by thermal models, particularly in the C ring and Cassini Division (Ferrari and Leyrat [2006], Morishima et al. [2009, 2010]). Conservation principles suggest that such models underestimate heating of the rings in these cases, as it is clearly unphysical for the rings to radiate significantly more energy than is incident upon them. In this presentation, we will describe our efforts to resolve this paradox and determine what doing so can teach us about Saturn's rings. This research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under contract with NASA. Copyright 2012 California Institute of Technology. Government sponsorship acknowledged.

  15. Interocular asymmetry of the visual field defects in newly diagnosed normal-tension glaucoma, primary open-angle glaucoma, and chronic angle-closure glaucoma.

    Science.gov (United States)

    Huang, Ping; Shi, Yan; Wang, Xin; Liu, Mugen; Zhang, Chun

    2014-09-01

    To compare the interocular asymmetry of visual field loss in newly diagnosed normal-tension glaucoma (NTG), primary open-angle glaucoma (POAG), and chronic angle-closure glaucoma (CACG) patients. Visual field results of 117 newly diagnosed, treatment-naive glaucoma patients (42 NTG, 38 POAG, and 37 CACG) were studied retrospectively. The following 3 visual field defect parameters were used to evaluate the interocular asymmetry: (1) global indices; (2) local mean deviations (MDs) of 6 predefined visual field areas; and (3) stage designated by glaucoma staging system 2. The differences of the above parameters between the trial eye (the eye with greater MDs) and the fellow eye in each subject were defined as interocular asymmetry scores. Interocular asymmetry of visual field loss was presented in all the 3 groups (all P0.05). Interocular asymmetry scores of glaucoma staging system 2 had no significant difference among the 3 groups (P=0.068). All CACG, POAG, and NTG groups presented with interocular asymmetric visual field loss at the time of diagnosis. CACG had greater interocular asymmetry compared with NTG and POAG. No significant interocular asymmetry difference was observed between NTG and POAG.

  16. Collagen matrix compared with mitomycin C for treatment of primary open-angle glaucoma with trabeculectomy performed

    Directory of Open Access Journals (Sweden)

    Lei Yu

    2017-09-01

    Full Text Available AIM:To evaluate the effectiveness and safety between trabeculectomy with collagen matrix versus trabeculectomy with mitomycin C(MMCfor patients with primary open-angle glaucoma(POAG.METHODS: In this prospective randomized comparative study from January 2015 to December 2016. Thirty-two eyes presented with POAG were included in this study, 14 eyes treated by trabeculectomy with subconjunctival implant of collagen matrix(study groupand the other 18 eyes treated by trabeculectomy with mitomycin C. Postoperative IOP, the success rate of operation, number of postoperative glaucoma medications and postoperative complications were recorded. Each patient was followed up at least 6mo. RESULTS: The mean postoperative IOP was statistically different between the study group and the control group after 1d(PP>0.05, and the mean postoperative IOP was statistically different between the two groups(PP>0.05. The IOP decreased at 1d after openations compared with before, kept stable at 1wk to 6mo. IOP of study group was lowen than control. IOP was controlled by glaucoma medications in the study group by 28% compared to control group by 33% at 6mo after operation, but there was no significant difference. There was no significant difference between the study group and the control group in complications(PCONCLUSION: Trabeculectomy with collagen matrix implant is comparable to the use of MMC with a similar success rate in open-angle glaucoma and the range in reducing intraocular pressure was significantly higher than that of MMC and it can significantly avoid the occurrence of low IOP postoperatively, transient anterior chamber, conjunctival wound leakage complications has no advantages compared with the use of MMC.

  17. Structure-Function Correlations using Scanning Laser Polarimetry in Primary Angle-Closure Glaucoma and Primary Open Angle Glaucoma

    Science.gov (United States)

    Lee, Pei-Jung; Liu, Catherine Jui-Ling.; Wojciechowski, Robert; Bailey-Wilson, Joan E.; Cheng, Ching-Yu

    2010-01-01

    Purpose To assess the correlations between retinal nerve fiber layer (RNFL) thickness measured with scanning laser polarimetry (SLP) and visual field (VF) sensitivity in primary open angle glaucoma (POAG) and primary angle-closure glaucoma (PACG). Design Prospective, comparative, observational cases series Methods Fifty patients with POAG and 56 with PACG were examined using SLP with variable corneal compensation (GDx VCC) and Humphrey VF analyzer between August 2005 and July 2006 at Taipei Veterans General Hospital. Correlations between RNFL thickness and VF sensitivity, expressed as mean sensitivity (MS) in both decibel (dB) and 1/Lambert (L) scales, were estimated by Spearman's rank correlation coefficient (rs) and multivariate median regression models (pseudo R2). The correlations were determined globally and for six RNFL sectors and their corresponding VF regions. Results The correlation between RNFL thickness and MS (in dB) was weaker in the PACG group (rs = 0.38, P = 0.004, pseudo R2 = 0.17) than in the POAG group (rs = 0.51, P <0.001, pseudo R2 = 0.31), but the difference in the magnitude of correlation was not significant (P = 0.42).With Bonferroni correction, the structure-function correlation was significant in the superotemporal (rs = 0.62), superonasal (rs = 0.56), inferonasal (rs = 0.53), and inferotemporal (rs = 0.50) sectors in the POAG group (all P <0.001), while it was significant only in the superotemporal (rs = 0.53) and inferotemporal (rs = 0.48) sectors in the PACG group (both P <0.001). The results were similar when MS was expressed as 1/L scale. Conclusions Both POAG and PACG eyes had moderate structure-function correlations using SLP. Compared to eyes with POAG, fewer RNFL sectors have significant structure-function correlations in eyes with PACG. PMID:20202618

  18. Surgical Outcomes of Gonioscopy-assisted Transluminal Trabeculotomy (GATT) in Patients With Open-angle Glaucoma.

    Science.gov (United States)

    Rahmatnejad, Kamran; Pruzan, Noelle L; Amanullah, Sarah; Shaukat, Bilal A; Resende, Arthur F; Waisbourd, Michael; Zhan, Tingting; Moster, Marlene R

    2017-12-01

    To evaluate the efficacy and safety of gonioscopy-assisted transluminal trabeculotomy (GATT) in patients with open-angle glaucoma. A retrospective chart review of adult patients who underwent GATT due to inadequately controlled intraocular pressure (IOP) or intolerance to medication. Main outcome measures were success rate, IOP, and number of glaucoma medications. Success was defined as IOP reduction >20% from baseline or IOP between 5 to 21 mm Hg, and no need for further glaucoma surgery. When success criteria were not met for any postoperative visit >3 months after surgery, failure was determined. In total, 66 patients, average age 62.9±14.9 years (50.8% female) were included in the analysis. Average follow-up was 11.9 months (range, 3 to 30 mo) and overall success rate was 63.0%. Mean IOP was 26.1±9.9 mm Hg preoperatively and 14.6±4.7 mm Hg at 12 months (44% IOP decrease; P<0.001). Mean number of medications decreased from 3.1±1.1 preoperatively to 1.2±0.9 at 12 months (P<0.001). No significant differences between patients with primary open-angle glaucoma and other types of glaucoma were found.The rate of hyphema at 1 week and 1 month postoperatively was 38% and 6%, respectively. Overall GATT success rate among white and black patients was 69% and 42%, respectively, which was statistically significant (P<0.05). The future of GATT as a minimally invasive glaucoma surgery in adults seems promising. This position is supported by its low rate of long-term complications and the conjunctiva-sparing nature of the surgery.

  19. Simulation studies of a new 'OpenPET' geometry based on a quad unit of detector rings

    Energy Technology Data Exchange (ETDEWEB)

    Yamaya, Taiga; Yoshida, Eiji; Nishikido, Fumihiko; Shibuya, Kengo; Inadama, Naoko; Murayama, Hideo [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Inaniwa, Taku [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan)], E-mail: taiga@nirs.go.jp

    2009-03-07

    We have proposed an 'OpenPET' geometry which consists of two detector rings of axial length W each axially separated by a gap G. In order to obtain an axially continuous field-of-view (FOV) of 2W+G, the maximum limit for G must be W. However, two valleys of sensitivity appear, one on each side of the gap. In practice, the gap should be Grings obtained by dividing each right and left unit of detector rings into two units. The inner two units formed the main gap, and the outer two units were appropriately placed to improve the uniformity of sensitivity. The geometry was optimized to minimize the standard deviation of the sensitivity distribution. Numerical simulation results supported the effectiveness of the proposed method. The outer units compensated for the sensitivity valleys on both sides of the main gap. A more appropriate geometry should be designed for the desired application, such as a long axial FOV PET and in-beam PET.

  20. PREFACE: Special section on vortex rings Special section on vortex rings

    Science.gov (United States)

    Fukumoto, Yasuhide

    2009-10-01

    This special section of Fluid Dynamics Research includes five articles on vortex rings in both classical and quantum fluids. The leading scientists of the field describe the trends in and the state-of-the-art development of experiments, theories and numerical simulations of vortex rings. The year 2008 was the 150th anniversary of 'vortex motion' since Hermann von Helmholtz opened up this field. In 1858, Helmholtz published a paper in Crelle's Journal which put forward the concept of 'vorticity' and made the first analysis of vortex motion. Fluid mechanics before that was limited to irrotational motion. In the absence of vorticity, the motion of an incompressible homogeneous fluid is virtually equivalent to a rigid-body motion in the sense that the fluid motion is determined once the boundary configuration is specified. Helmholtz proved, among other things, that, without viscosity, a vortex line is frozen into the fluid. This Helmholtz's law immediately implies the preservation of knots and links of vortex lines and its implication is enormous. One of the major trends of fluid mechanics since the latter half of the 20th century is to clarify the topological meaning of Helmholtz's law and to exploit it to develop theoretical and numerical methods to find the solutions of the Euler equations and to develop experimental techniques to gain an insight into fluid motion. Vortex rings are prominent coherent structures in a variety of fluid motions from the microscopic scale, through human and mesoscale to astrophysical scales, and have attracted people's interest. The late professor Philip G Saffman (1981) emphasized the significance of studies on vortex rings. One particular motion exemplifies the whole range of problems of vortex motion and is also a commonly known phenomenon, namely the vortex ring or smoke ring. Vortex rings are easily produced by dropping drops of one liquid into another, or by puffing fluid out of a hole, or by exhaling smoke if one has the skill

  1. SELECTIVE AND NONSELECTIVE β-BLOCKERS IN PRIMARY OPEN ANGLE GLAUCOMA THERAPY – RESULTS OF COLOR DOPPLER SONOGRAPHY

    Directory of Open Access Journals (Sweden)

    Vukoslava Maričić-Došen

    2002-12-01

    Full Text Available Background. Primary open angle glaucoma (POAG is a syndrome of progressive optic neuropathy characterized by optic nerve head excavation and visual field defects. Poor correlation between IOP and progression of glaucoma disease sets vascular mechanism in the centre of attention. By Color Doppler sonography, quantification of blood flow changes in vessels, which supply optic nerve head, is possible. We wanted to find out whether there are changes in the circulation of central retinal artery and posterior ciliary arteries in patients with primary open angle glaucoma treated with selective or nonselective β -blockers.Methods. 44 patients (88 eyes were divided into two groups: group 1: 22 patients (44 eyes treated with selective β -blockers (Betaxolol 0.5% and group 2: 22 patients (44 eyes treated with nonselective β -blockers (Timolol 0.5%. Vascular indices (RI, PI were measured in the central retinal artery and posterior ciliary arteries.Results. We found decreased blood flow and increased vascular indices in both groups of patients, statistically significant difference between group 1 and group 2: blood flow velocity was higher and vascular indices were lower in group 1 (Betaxolol 0.5% compared to group 2 (Timolol 0..5%.Conclusions. Selective β -blockers (calcium channel blockers act more vasoactively and neuroprotectively comparing to nonselective β -blockers.

  2. Clinical Assessment of Lamina Cribrosa Curvature in Eyes with Primary Open-Angle Glaucoma.

    Directory of Open Access Journals (Sweden)

    Yong Woo Kim

    Full Text Available Quantitative evaluation of lamina cribrosa (LC posterior bowing in primary open-angle glaucoma (POAG eyes using swept-source optical coherence tomography.Patients with POAG (n = 123 eyes and healthy individuals of a similar age (n = 92 eyes were prospectively recruited. Anterior laminar insertion depth (ALID was defined as the vertical distance between the anterior laminar insertion and a reference plane connecting the Bruch's membrane openings (BMO. The mean LC depth (mLCD was approximated by dividing the area enclosed by the anterior LC, the BMO reference plane, and the two vertical lines for ALID measurement by the length between those two vertical lines. The LC curvature index was defined as the difference between the mLCD and the ALID. The factors influencing the LC curvature index were evaluated.The ALID and mLCD were significantly larger in POAG eyes than in healthy controls (P -6 dB and moderate-to-advanced glaucoma (MD < -6 dB, P = 0.95.LC posterior bowing was increased in POAG eyes, and was significantly associated with structural optic nerve head (ONH changes but not with functional glaucoma severity. Quantitative evaluation of LC curvature can facilitate assessment of glaucomatous ONH change.

  3. Collector ring project at FAIR

    International Nuclear Information System (INIS)

    Dolinskii, A; Blell, U; Dimopoulou, C; Gorda, O; Leibrock, H; Litvinov, S; Laier, U; Schurig, I; Weinrich, U; Berkaev, D; Koop, I; Starostenko, A; Shatunov, P

    2015-01-01

    The collector ring is a dedicated ring for fast cooling of ions coming from separators at the FAIR project. To accommodate optimal technical solutions, a structure of a magnet lattice was recently reviewed and modified. Consequently, more appropriate technical solutions for the main magnets could be adopted. A general layout and design of the present machine is shown. The demanding extraction schemes have been detailed and open design issues were completed. (paper)

  4. Highly conductive, transparent flexible films based on open rings of multi-walled carbon nanotubes

    International Nuclear Information System (INIS)

    Ko, Wen-Yin; Su, Jun-Wei; Guo, Chian-Hua; Fu, Shu-Juan; Hsu, Chuen-Yuan; Lin, Kuan-Jiuh

    2011-01-01

    Open rings of multi-walled carbon nanotubes were stacked to form porous networks on a poly(ethylene terephthalate) substrate to form a flexible conducting film (MWCNT-PET) with good electrical conductivity and transparency by a combination of ultrasonic atomization and spin-coating technique. To enhance the electric flexibility, we spin-coated a cast film of poly(vinyl alcohol) onto the MWCNT-PET substrate, which then underwent a thermo-compression process. Field-emission scanning electron microscopy of the cross-sectional morphology illustrates that the film has a robust network with a thickness of ∼ 175 nm, and it remarkably exhibits a sheet resistance of approximately 370 Ω/sq with ∼ 77% transmittance at 550 nm even after 500 bending cycles. This electrical conductivity is much superior to that of other MWCNT-based transparent flexible films.

  5. Proton storage rings

    International Nuclear Information System (INIS)

    Rau, R.R.

    1978-04-01

    A discussion is given of proton storage ring beam dynamic characteristics. Topics considered include: (1) beam energy; (2) beam luminosity; (3) limits on beam current; (4) beam site; (5) crossing angle; (6) beam--beam interaction; (7) longitudinal instability; (8) effects of scattering processes; (9) beam production; and (10) high magnetic fields. Much of the discussion is related to the design parameters of ISABELLE, a 400 x 400 GeV proton---proton intersecting storage accelerator to be built at Brookhaven National Laboratory

  6. Cost-effectiveness analysis of iStent trabecular microbypass stent for patients with open-angle glaucoma in Colombia

    OpenAIRE

    Osorio, Urpy; Ordoñez, Angelica

    2018-01-01

    Objective: To estimate cost-effectiveness of trabecular micro bypass stent versus laser trabeculoplasty or medications only, for patients with open-angle glaucoma in setting of Colombian System Health. Methods: This is a cost-effectiveness analysis that based its assumptions in external data sources, used to extrapolate the quality of life related to health, survival and costs. A Markov model, with stages from 0 (ocular hypertension without glaucoma) to 5 and bilateral blindness, was develope...

  7. Genes of the unfolded protein response pathway harbor risk alleles for primary open angle glaucoma.

    Directory of Open Access Journals (Sweden)

    Mary Anna Carbone

    Full Text Available The statistical power of genome-wide association (GWA studies to detect risk alleles for human diseases is limited by the unfavorable ratio of SNPs to study subjects. This multiple testing problem can be surmounted with very large population sizes when common alleles of large effects give rise to disease status. However, GWA approaches fall short when many rare alleles may give rise to a common disease, or when the number of subjects that can be recruited is limited. Here, we demonstrate that this multiple testing problem can be overcome by a comparative genomics approach in which an initial genome-wide screen in a genetically amenable model organism is used to identify human orthologues that may harbor risk alleles for adult-onset primary open angle glaucoma (POAG. Glaucoma is a major cause of blindness, which affects over 60 million people worldwide. Several genes have been associated with juvenile onset glaucoma, but genetic factors that predispose to adult onset primary open angle glaucoma (POAG remain largely unknown. Previous genome-wide analysis in a Drosophila ocular hypertension model identified transcripts with altered regulation and showed induction of the unfolded protein response (UPR upon overexpression of transgenic human glaucoma-associated myocilin (MYOC. We selected 16 orthologous genes with 62 polymorphic markers and identified in two independent human populations two genes of the UPR that harbor POAG risk alleles, BIRC6 and PDIA5. Thus, effectiveness of the UPR in response to accumulation of misfolded or aggregated proteins may contribute to the pathogenesis of POAG and provide targets for early therapeutic intervention.

  8. Genes of the unfolded protein response pathway harbor risk alleles for primary open angle glaucoma.

    Science.gov (United States)

    Carbone, Mary Anna; Chen, Yuhong; Hughes, Guy A; Weinreb, Robert N; Zabriskie, Norman A; Zhang, Kang; Anholt, Robert R H

    2011-01-01

    The statistical power of genome-wide association (GWA) studies to detect risk alleles for human diseases is limited by the unfavorable ratio of SNPs to study subjects. This multiple testing problem can be surmounted with very large population sizes when common alleles of large effects give rise to disease status. However, GWA approaches fall short when many rare alleles may give rise to a common disease, or when the number of subjects that can be recruited is limited. Here, we demonstrate that this multiple testing problem can be overcome by a comparative genomics approach in which an initial genome-wide screen in a genetically amenable model organism is used to identify human orthologues that may harbor risk alleles for adult-onset primary open angle glaucoma (POAG). Glaucoma is a major cause of blindness, which affects over 60 million people worldwide. Several genes have been associated with juvenile onset glaucoma, but genetic factors that predispose to adult onset primary open angle glaucoma (POAG) remain largely unknown. Previous genome-wide analysis in a Drosophila ocular hypertension model identified transcripts with altered regulation and showed induction of the unfolded protein response (UPR) upon overexpression of transgenic human glaucoma-associated myocilin (MYOC). We selected 16 orthologous genes with 62 polymorphic markers and identified in two independent human populations two genes of the UPR that harbor POAG risk alleles, BIRC6 and PDIA5. Thus, effectiveness of the UPR in response to accumulation of misfolded or aggregated proteins may contribute to the pathogenesis of POAG and provide targets for early therapeutic intervention.

  9. Associations between the deletion polymorphism of the angiotensin 1-converting enzyme gene and ocular signs of primary open-angle glaucoma

    NARCIS (Netherlands)

    Bunce, Catey; Hitchings, Roger A.; van Duijn, Cornelia M.; de Jong, Paulus T. V. M.; Vingerling, Johannes R.

    2005-01-01

    Primary open-angle glaucoma (POAG) is a leading cause of blindness. High intraocular pressure (IOP) has been shown to be a key risk factor for POAG. Topical application of angiotensin 1-converting enzyme (ACE) inhibitors has been shown to lower IOP, and angiotensin-induced increase in vascular tone

  10. Two Electron States in a Quantum Ring on a Sphere

    International Nuclear Information System (INIS)

    Kazaryan, Eduard M.; Shahnazaryan, Vanik A.; Sarkisyan, Hayk A.

    2014-01-01

    Two electron states in a quantum ring on a spherical surface are discussed. The problem is discussed within the frameworks of Russell–Saunders coupling scheme, that is, the spin–orbit coupling is neglected. Treating Coulomb interaction as a perturbation, the energy correction for different states is calculated. The dependence of the Coulomb interaction energy on external polar boundary angle of quantum ring is obtained. In analogue with the helium atom the concept of states exchange time is introduced, and its dependence on geometrical parameters of the ring is shown. (author)

  11. SXLS storage ring design

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    X-ray lithography has emerged as a strong candidate to meet the demands of ever finer linewidths on integrated circuits, particularly for linewidths less than .25 microns. Proximity printing X-ray lithography makes use of soft X-rays to shadow print an image of a mask onto a semiconductor wafer to produce integrated circuits. To generate the required X-rays in sufficient quantities to make commercial production viable, electron storage rings have been proposed as the soft X-ray sources. Existing storage rings have been used to do the initial development work and the success of these efforts has led the lithographers to request that new rings be constructed that are dedicated to X-ray lithography. As a result of a series of workshops held at BNL [10.3] which were attended by both semiconductor and accelerator scientists, the following set of zeroth order specifications' on the light and electron beam of a storage ring for X-ray lithography were developed: critical wavelength of light: λ c = 6 to 10 angstroms, white light power: P = 0.25 to 2.5 watts/mrad, horizontal collection angle per port: θ = 10 to 50 mrad, electron beam sizes: σ x ∼ σ y y ' < 1 mrad

  12. Saturn’s ring temperatures at equinox

    Science.gov (United States)

    Spilker, Linda J.; Ferrari, C.; Morishima, R.

    2013-10-01

    Modeling the thermal emission of Saturn's rings is challenging due to the numerous heating sources as well as the structural properties of the disk and of the particles that are closely related. At equinox, however, the main rings are externally heated by Saturn alone and the problem is somewhat simplified. We test the abilities of our current models to reproduce the temperatures observed with the Cassini CIRS instrument around equinox in August 2009. A simple semi-analytic model which includes mutual shadowing effects can mostly explain the radial profile of the equinox ring temperatures, except the model predicts lower temperatures than those observed for the A ring. The temperature variation at a given saturnocentric radius is primarily caused by observational geometry variations relative to Saturn. The observed temperature increases with decreasing Saturn-ring-observer angle. In addition, we found evidence that the leading hemispheres of particles are warmer than the trailing hemispheres at least for the C ring and probably for the A and B rings as well. This is explained if some fraction of particles has spin rates lower than the synchronous rotation rate as predicted by N-body simulations. The spin model for a monolayer ring (Ferrari, C., Leyrat, C., 2006, Astron. Astrophys. 447, 745-760) can fit the temperature variations with spacecraft longitude observed in the C ring with currently known thermal properties and a mixing of slow and fast rotators. The multilayer model (Morishima, R., Salo, H., Ohtsuki, K., 2009, Icarus 201, 634-654) can reproduce the temperatures of the B and C rings but gives A ring temperatures that are significantly lower than those observed as does the simple semi-analytic model. More advanced models which take into account self-gravity wakes may explain the A ring temperature behavior.

  13. Subluxation of the crystalline lens: a no-ring approach.

    Science.gov (United States)

    Rodrigues, Antonio Carlos L; Trivedi, Rupal H; Wilson, M Edward

    2012-01-01

    To report the surgical technique and outcomes of a no-ring approach to posterior chamber intraocular lens (IOL) implantation in children and young adults with subluxation of the crystalline lens. A three-piece 5.5-mm hydrophobic acrylic IOL was implanted in which the optic and one haptic were inside the capsular bag and the other haptic was in the ciliary sulcus. The implantations were done in 13 eyes of 10 patients with lens subluxation. One haptic was fixated in the ciliary sulcus by passing it through an operculum-shaped opening in the capsular bag edge, made between 2 and 3 clock hours, clockwise from the middle point of the subluxated area. The mean age of the 10 patients was 12.61 ± 8.04 years and the mean follow-up was 21.38 ± 11.29 months. The mean preoperative and postoperative best-corrected visual acuity (BCVA) was 1.15 ± 0.58 and 0.37 ± 0.17 logarithm of the minimum angle of resolution, respectively, in 11 measured eyes. The postoperative BCVA was 20/40 or better in 4 eyes (36.36%), between 20/40 and 20/60 in 6 eyes (54.54%), and between 20/80 and 20/100 in 1 eye (9.09%). The BCVA improved in all eyes. Postoperative IOL decentration between 1.0 and 1.5 mm occurred in 3 of 13 eyes (23.08%). The results indicate that the no-ring technique allows centration of an IOL implanted into a subluxated capsular bag without using capsule tension rings. Copyright 2012, SLACK Incorporated.

  14. Fast and Living Ring-Opening Polymerization of α-Amino Acid N-Carboxyanhydrides Triggered by an "Alliance" of Primary and Secondary Amines at Room Temperature

    KAUST Repository

    Zhao, Wei; Gnanou, Yves; Hadjichristidis, Nikolaos

    2015-01-01

    A novel highly efficient strategy, based on an "alliance" of primary and secondary amine initiators, was successfully developed allowing the fast and living ring-opening polymerization (ROP) of α-amino acid N-carboxyanhydrides (NCAs) at room temperature. (Chemical Equation Presented). © 2015 American Chemical Society.

  15. Fast and Living Ring-Opening Polymerization of α-Amino Acid N-Carboxyanhydrides Triggered by an "Alliance" of Primary and Secondary Amines at Room Temperature

    KAUST Repository

    Zhao, Wei

    2015-04-13

    A novel highly efficient strategy, based on an "alliance" of primary and secondary amine initiators, was successfully developed allowing the fast and living ring-opening polymerization (ROP) of α-amino acid N-carboxyanhydrides (NCAs) at room temperature. (Chemical Equation Presented). © 2015 American Chemical Society.

  16. Influence of crack opening and incident wave angle on second harmonic generation of Lamb waves

    Science.gov (United States)

    Yang, Yi; Ng, Ching-Tai; Kotousov, Andrei

    2018-05-01

    Techniques utilising second harmonic generation (SHG) have proven their great potential in detecting contact-type damage. However, the gap between the practical applications and laboratory studies is still quite large. The current work is aimed to bridge this gap by investigating the effects of the applied load and incident wave angle on the detectability of fatigue cracks at various lengths. Both effects are critical for practical implementations of these techniques. The present experimental study supported by three-dimensional (3D) finite element (FE) modelling has demonstrated that the applied load, which changes the crack opening and, subsequently, the contact nonlinearity, significantly affects the amplitude of the second harmonic generated by the fundamental symmetric mode (S0) of Lamb wave. This amplitude is also dependent on the length of the fatigue crack as well as the incident wave angle. The experimental and FE results correlate well, so the modelling approach can be implemented for practical design of damage monitoring systems as well as for the evaluation of the severity of the fatigue cracks.

  17. Demonstration of angle widening using EyeCam after laser peripheral iridotomy in eyes with angle closure.

    Science.gov (United States)

    Perera, Shamira A; Quek, Desmond T; Baskaran, Mani; Tun, Tin A; Kumar, Rajesh S; Friedman, David S; Aung, Tin

    2010-06-01

    To evaluate EyeCam in detecting changes in angle configuration after laser peripheral iridotomy (LPI) in comparison to gonioscopy, the reference standard. Prospective comparative study. Twenty-four subjects (24 eyes) with primary angle-closure glaucoma (PACG) were recruited. Gonioscopy and EyeCam (Clarity Medical Systems) imaging of all 4 angle quadrants were performed, before and 2 weeks after LPI. Images were graded according to angle structures visible by an observer masked to clinical data or the status of LPI, and were performed in a random order. Angle closure in a quadrant was defined as the inability to visualize the posterior trabecular meshwork. We determined the number of quadrants with closed angles and the mean number of clock hours of angle closure before and after LPI in comparison to gonioscopy. Using EyeCam, all 24 eyes showed at least 1 quadrant of angle widening after LPI. The mean number of clock hours of angle closure decreased significantly, from 8.15 +/- 3.47 clock hours before LPI to 1.75 +/- 2.27 clock hours after LPI (P gonioscopy showed 1.0 +/- 1.41 (95% CI, 0.43-1.57) quadrants opening from closed to open after LPI compared to 2.0 +/- 1.28 (95% CI, 1.49-2.51, P = .009) quadrants with EyeCam. Intra-observer reproducibility of grading the extent of angle closure in clock hours in EyeCam images was moderate to good (intraclass correlation coefficient 0.831). EyeCam may be used to document changes in angle configuration after LPI in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.

  18. Robust gap repair in the contractile ring ensures timely completion of cytokinesis.

    Science.gov (United States)

    Silva, Ana M; Osório, Daniel S; Pereira, Antonio J; Maiato, Helder; Pinto, Inês Mendes; Rubinstein, Boris; Gassmann, Reto; Telley, Ivo Andreas; Carvalho, Ana Xavier

    2016-12-19

    Cytokinesis in animal cells requires the constriction of an actomyosin contractile ring, whose architecture and mechanism remain poorly understood. We use laser microsurgery to explore the biophysical properties of constricting rings in Caenorhabditis elegans embryos. Laser cutting causes rings to snap open. However, instead of disintegrating, ring topology recovers and constriction proceeds. In response to severing, a finite gap forms and is repaired by recruitment of new material in an actin polymerization-dependent manner. An open ring is able to constrict, and rings repair from successive cuts. After gap repair, an increase in constriction velocity allows cytokinesis to complete at the same time as controls. Our analysis demonstrates that tension in the ring increases while net cortical tension at the site of ingression decreases throughout constriction and suggests that cytokinesis is accomplished by contractile modules that assemble and contract autonomously, enabling local repair of the actomyosin network. Consequently, cytokinesis is a highly robust process impervious to discontinuities in contractile ring structure. © 2016 Silva et al.

  19. Towards an Understanding of Radiative Factors on Planetary Rings: a Perspective from Cassini CIRS Observations at Saturn Equinox

    Science.gov (United States)

    Brooks, Shawn M.; Spilker, L.; Edgington, S. G.; Déau, E.; Pilorz, S. H.

    2012-10-01

    Since arriving at Saturn in 2004, Cassini's Composite Infrared Spectrometer has recorded tens of millions of spectra of Saturn’s rings (personal communication, M. Segura). CIRS records far infrared radiation (16.7-1000 microns) at focal plane 1 (FP1). Thermal emission from Saturn’s rings peaks at FP1 wavelengths. CIRS spectra are well characterized as blackbody emission at an effective temperature Te, multiplied by a scalar factor related to ring emissivity (Spilker et al. [2005, 2006]). CIRS can therefore characterize the rings' temperature and study the thermal environment to which the ring particles are subject. We focus on CIRS data from the 2009 Saturnian equinox. As the Sun's disk crossed the ring plane, CIRS obtained several radial scans of the rings at a variety of phase angles, local hour angles and distances. With the Sun's rays striking the rings at an incidence angle of zero, solar heating is virtually absent, and thermal radiation from Saturn and sunlight reflected by Saturn dominate the thermal environment. These observations present an apparent paradox. Equinox data show that the flux of thermal energy radiated by the rings is roughly equivalent to or even exceeds the energy incident upon them as prescribed by thermal models (Froidevaux [1981], Ferrari and Leyrat [2006], Morishima et al. [2009, 2010]). This apparent energy excess is largest in the C ring and Cassini Division. Conservation principles suggest that models underestimate heating of the rings, as it is clearly unphysical for the rings to radiate significantly more energy than is incident upon them. In this presentation, we will attempt to resolve this paradox and determine what this can teach us about Saturn's rings. This research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under contract with NASA. Copyright 2012 California Institute of Technology. Government sponsorship acknowledged.

  20. Ring shear characteristics of clays in fractured-zone-landslide. Hasaitai chisuberichi no nenseido no ring sendan tokusei

    Energy Technology Data Exchange (ETDEWEB)

    Yatabe, R; Yagi, N; Enoki, M [Ehime Univ., Ehime (Japan). Faculty of Engineering

    1991-09-20

    The importance of study on the residual strength, in addition to the peak strength, has been pointed out for the study of landslides. The residual strength characteristics, effects of shearing rate, and grain size of clays, as well as the residual strength characteristics of clay minerals of a fractured zone landslide were examined by ring shear tests. The residual friction angles {phi}{sub r} of the tested clays of the fractured zone landslide were from 10 to 31{degree}, and were smaller than those of shearing resistance angles {phi}{prime} obtained by triaxial tests by 5 to 15{degree}. Contrary to the pointing out made hitherto, no correlation between clay content CF and plastic index was recognized for {phi}{sub r} of clays of a fractured zone landslide. As regards CF, the relation with CF was far below the lowest limit indicated by now. Ring shear characteristics of principal structural clay minerals, vermiculite, mica, illite, chlorite, and kaolinite were investigated. {phi}{sub r} of these clay minerals were in the range from 10 to 25{degree}. 20 refs., 14 figs., 2 tabs.

  1. Comparative analysis of the results of various physical therapy techniques in the treatment of patients with primary open-angle glaucoma with chronic cerebral ischemia

    Directory of Open Access Journals (Sweden)

    Lazarev М.S.

    2012-06-01

    Full Text Available

    Aim of the study: to evaluate the effectiveness of the techniques of dynamic simultaneous transcranial magnetic therapy and resonance, and electrical stimulation, transcranial magnetic therapy and dynamic laser stimulation, magnetic simpatokorrektsii in the treatment of patients with primary open-angle glaucoma with chronic cerebral ischemia. Techniques. We observed 184 patients diagnosed with primary open-angle glaucoma who received different physical therapy techniques. Results. Patients treated with transcranial magnetic therapy and electrical stimulation or laser stimulation, in addition to improving visual function and improve the bioelectrical activity of the visual cortex, more pronounced than in other groups also observed the activation of the intraocular blood fow. Application of magnetic simpatokorrektsii allows for improvement of basic functional, electrophysiological and hemodynamic performance by reducing the activity of the sympathetic nervous system and reduce the vasopressor effect. Conclusion. Transcranial magnetic therapy in combination with electrical stimulation or laser stimulation is effective in the treatment of patients with POAG. In patients with primary open-angle glaucoma with chronic cerebral ischemia technique of magnetic sim-patokorrektsii compared with traditional methods of vasoactive therapy is more effective, which is manifested not only increase the visual functions, but also a decrease in cognitive impairment.

  2. Morning glory syndrome associated with primary open angle glaucoma: Case report

    Directory of Open Access Journals (Sweden)

    Božić Marija

    2014-01-01

    Full Text Available Introduction. Morning glory syndrome (MGS is a rare congenital optic disc anomaly, first reported in 1970. MGS is a nonprogressive and untreatable condition, which usually occurs as an isolated ocular anomaly, and can be associated with the increased incidence of nonrhegmatogenous retinal detachment, and also with strabismus, afferent pupillary defect, visual field defects, presence of hyaloids artery remnants, ciliary body cyst, congenital cataract, lid hemangioma and preretinal gliosis. Case Outline. We report a clinical case of MGS associated with primary open angle glaucoma. The use of sophisticated diagnostic tools, such as retinal tomography and visual field testing is limited if multiple eye conditions are present, since optic disc does not have “usual” appearance that can be analyzed according to standard statistical databases. Conclusion. In treating and follow up of glaucoma cases associated with other diseases and conditions that affect the appearance and function of the optic nerve head, sometimes the use of modern technological methods is limited due to difficult interpretation of the obtained results.

  3. YCl3-Catalyzed Highly Selective Ring Opening of Epoxides by Amines at Room Temperature and under Solvent-Free Conditions

    Directory of Open Access Journals (Sweden)

    Wuttichai Natongchai

    2017-11-01

    Full Text Available A simple, efficient, and environmentally benign approach for the synthesis of β-amino alcohols is herein described. YCl3 efficiently carried out the ring opening of epoxides by amines to produce β-amino alcohols under solvent-free conditions at room temperature. This catalytic approach is very effective, with several aromatic and aliphatic oxiranes and amines. A mere 1 mol % concentration of YCl3 is enough to deliver β-amino alcohols in good to excellent yields with high regioselectivity.

  4. Transcatheter Mitral Valve-in-Ring Implantation

    LENUS (Irish Health Repository)

    Tanner, RE

    2018-05-01

    Failed surgical mitral valve repair using an annuloplasty ring has traditionally been treated with surgical valve replacement or repair1. For patients at high risk for repeat open heart surgery, placement of a trans-catheter aortic valve (i.e., TAVI valve) within the mitral ring (i.e., Mitral-Valve-in-Ring, MViR) has emerged as a novel alternative treatment strategy2-5 . We describe our experience of a failed mitral valve repair that was successfully treated with a TAVI valve delivered via the trans-septal approach, and summarise the data relating to this emerging treatment strategy.

  5. Detection and direction discrimination of single vortex rings by harbour seals (Phoca vitulina).

    Science.gov (United States)

    Krüger, Yvonne; Hanke, Wolf; Miersch, Lars; Dehnhardt, Guido

    2018-04-25

    Harbour seals possess highly sensitive vibrissae that enable them to track hydrodynamic trails left behind by a swimming fish. Most of these trails contain vortex rings as a main hydrodynamic component. They may reveal information about their generator as the trails differ depending on the fish species, the fish's body shape, size and swimming style. In addition, fish generate single vortex rings in diverse natural situations. In this study, the ability of blindfolded stationary harbour seals to detect and analyse single vortex rings regarding directional information has been investigated. In three different behavioural experiments, the animals were trained to respond to single artificially generated vortex rings. The results show that harbour seals are able to respond to a variety of different vortex rings upon vibrissal stimulation. The investigation of the minimum hydrodynamically perceivable angle revealed that it is at least as small as 5.7 deg, which was the smallest adjustable angle. Moreover, harbour seals are capable of analysing the travel direction of a vortex ring perceived by the mystacial vibrissae irrespective of whether the vibrissae were stimulated ipsilaterally or contralaterally. In situations in which no complex hydrodynamic trail is available, it is advantageous for a hunting seal to be able to extract information from a single vortex ring. © 2018. Published by The Company of Biologists Ltd.

  6. Evanescent-wave coupled right angled buried waveguide: Applications in carbon nanotube mode-locking

    International Nuclear Information System (INIS)

    Mary, R.; Thomson, R. R.; Kar, A. K.; Brown, G.; Beecher, S. J.; Popa, D.; Sun, Z.; Torrisi, F.; Hasan, T.; Milana, S.; Bonaccorso, F.; Ferrari, A. C.

    2013-01-01

    We present an evanescent-field device based on a right-angled waveguide. This consists of orthogonal waveguides, with their points of intersection lying along an angled facet of the chip. Light guided along one waveguide is incident at the angled dielectric-air facet at an angle exceeding the critical angle, so that the totally internally reflected light is coupled into the second waveguide. By depositing a nanotube film on the angled surface, the chip is then used to mode-lock an Erbium doped fiber ring laser with a repetition rate of 26 MHz, and pulse duration of 800 fs

  7. Argon laser trabeculoplasty as primary therapy in open angle glaucoma

    International Nuclear Information System (INIS)

    Mahar, P.S.; Jamali, K.K.

    2008-01-01

    To determine the effect of Argon Laser Trabeculoplasty (ALT) as a primary mode of therapy in reducing the intraocular Pressure (IOP) of patients diagnosed with Primary Open Angle Glaucoma (POAG). A total of 35 eyes of 35 patients with the gender distribution of 27 men and 8 women who were newly diagnosed with POAG, were included in this study. Mean age of the patients was 55.2 years with the range of 32 to 76 years. All of them were treated with argon laser trabeculoplasty as a primary mode of therapy. Intra ocular pressure was measured objectively using Goldman applanation tonometer, pre-and-post laser therapy. The pre-laser mean IOP was 27.63 mmHg (range 21-40 mmHg). The post-laser mean IOP measured at 6 months follow up was 15.5 mmHg (range 11 - 33 mmHg) with mean decrease of 12.1 mmHg. The decrease in IOP was seen in 32 eyes (95%) with no change observed in 3 (5%) eyes. The result shows a marked decline in IOP in patients with POAG who underwent ALT as a primary mode of treatment. Further studies with large sample size and longer follow-up will help in making future recommendations. (author)

  8. Geometric approach to the design of an imaging probe to evaluate the iridocorneal angle structures

    Science.gov (United States)

    Hong, Xun Jie Jeesmond; V. K., Shinoj; Murukeshan, V. M.; Baskaran, M.; Aung, Tin

    2017-06-01

    Photographic imaging methods allow the tracking of anatomical changes in the iridocorneal angle structures and the monitoring of treatment responses overtime. In this work, we aim to design an imaging probe to evaluate the iridocorneal angle structures using geometrical optics. We first perform an analytical analysis on light propagation from the anterior chamber of the eye to the exterior medium using Snell's law. This is followed by adopting a strategy to achieve uniform near field irradiance, by simplifying the complex non-rotational symmetric irradiance distribution of LEDs tilted at an angle. The optimization is based on the geometric design considerations of an angled circular ring array of 4 LEDs (or a 2 × 2 square LED array). The design equation give insights on variable parameters such as the illumination angle of the LEDs, ring array radius, viewing angle of the LEDs, and the working distance. A micro color CCD video camera that has sufficient resolution to resolve the iridocorneal angle structures at the required working distance is then chosen. The proposed design aspects fulfil the safety requirements recommended by the International Commission on Non-ionizing Radiation Protection.

  9. THE TREATMENT OF OPEN- AND NARROW-ANGLE GLAUCOMA

    African Journals Online (AJOL)

    1971-04-10

    Apr 10, 1971 ... glaucoma will be considered: narrow-angle glaucoma. (acute glaucoma) and ... emotional or a physical crisis. The pain is in the distribu- .... ness, not increased pressure, haunts people suffering from glaucoma'.' The saga of ...

  10. The association between primary open-angle glaucoma and fall: an observational study

    Directory of Open Access Journals (Sweden)

    Tanabe S

    2012-03-01

    Full Text Available Sachiko Tanabe1,2*, Kenya Yuki1*, Naoki Ozeki1, Daisuke Shiba1, Kazuo Tsubota11Department of Ophthalmology, Keio University School of Medicine, Shinanomachi 35, Tokyo, Japan; 2Tanabe Eye Clinic, Kai City, Yamanashi, Japan*These authors contributed equally to this workPurpose: Falls are among the most serious public health concerns for the elderly. Information conveyed via the visual sense is relevant to postural balance and movement, and proper visual function is essential to avoid falls. Here we investigated the prevalence of injurious falls among patients with primary open-angle glaucoma (POAG who were more than 45 years old, compared with comparably aged healthy subjects.Methods: This is a cross-sectional study. Consecutive patients who visited the Tanabe Eye Clinic, Yamanashi, Japan between January 1 and March 30, 2009 were screened for eligibility by ophthalmic examination. A total of 117 control subjects (77 men, 40 women; aged 60.2 ± 7.5 years who were free of ocular disease and 101 POAG patients (58 men, 43 women; aged 62.3 ± 8.7 years were consecutively enrolled. Participants answered a questionnaire on injurious fall experience during the previous 10 years. The prevalence of injurious fall in subjects with POAG versus healthy controls was examined with Fisher's exact test. Adjusted odds ratios and 95% confidence intervals were estimated with logistic regression models for the subjects with POAG (factors: age, gender, mean deviation in the better eye or worse eye.Results: The self-reported prevalence of injurious fall was 0.9% (1/117 in the control group and 6.9% (7/101 in the POAG group. The association between injurious fall and POAG was statistically significant (P = 0.026, Fisher's exact test. Within the POAG patients, the group reporting falls was significantly older and had a lower BMI, worse BCVA, and worse mean deviation in both the better and worse eye than the group reporting no falls. Worse mean deviation in the eye with

  11. Synthesis of poly(2-ethyl-2-oxazoline)-b-poly(styrene) copolymers via a dual initiator route combining cationic ring-opening polymerization and atom transfer radical polymerization

    NARCIS (Netherlands)

    Becer, C.R.; Paulus, R.M.; ppener, S.; Hoogenboom, R.; Fustin, C.A.; Gohy, J.M.W.; Schubert, U.S.

    2008-01-01

    Block copolymers of 2-ethyl-2-oxazoline (EtOx) and styrene were synthesized by a combination of cationic ring-opening polymerization (CROP) and atom transfer radical polymerization (ATRP). Initially, a detailed kinetic investigation for the ?-bromoisobutyrylbromide (BrEBBr) initiated CROP of EtOx

  12. Enhancement of strong-field multiple ionization in the vicinity of the conical intersection in 1,3-cyclohexadiene ring opening

    International Nuclear Information System (INIS)

    Petrovic, Vladimir S.; Kim, Jaehee; Schorb, Sebastian; White, James; Cryan, James P.; Zipp, Lucas; Glownia, J. Michael; Broege, Douglas; Miyabe, Shungo; Tao, Hongli; Martinez, Todd; Bucksbaum, Philip H.

    2013-01-01

    Nonradiative energy dissipation in electronically excited polyatomic molecules proceeds through conical intersections, loci of degeneracy between electronic states. We observe a marked enhancement of laser-induced double ionization in the vicinity of a conical intersection during a non-radiative transition. We measured double ionization by detecting the kinetic energy of ions released by laser-induced strong-field fragmentation during the ring-opening transition between 1,3-cyclohexadiene and 1,3,5-hexatriene. The enhancement of the double ionization correlates with the conical intersection between the HOMO and LUMO orbitals

  13. Recent Developments of Versatile Photoinitiating Systems for Cationic Ring Opening Polymerization Operating at Any Wavelengths and under Low Light Intensity Sources.

    Science.gov (United States)

    Lalevée, Jacques; Mokbel, Haifaa; Fouassier, Jean-Pierre

    2015-04-20

    Photoinitiators (PI) or photoinitiating systems (PIS) usable in light induced cationic polymerization (CP) and free radical promoted cationic polymerization (FRPCP) reactions (more specifically for cationic ring opening polymerization (ROP)) together with the involved mechanisms are briefly reviewed. The recent developments of novel two- and three-component PISs for CP and FRPCP upon exposure to low intensity blue to red lights is emphasized in details. Examples of such reactions under various experimental conditions are provided.

  14. Compact and Wide Stopband Lowpass Filter Using Open Complementary Split Ring Resonator and Defected Ground Structure

    Directory of Open Access Journals (Sweden)

    S. S. Karthikeyan

    2015-09-01

    Full Text Available A compact (0.16 λg x 0.08 λg and wide stop¬band lowpass filter design using open complementary split ring resonator (OCSRR and defected ground structure (DGS is presented in this paper. Low pass filter is con-structed using two cascaded stages of OCSRR. Since the rejection bandwidth of the OCSRR is narrow, tapered dumbbell shaped DGS section is placed under the OCSRR to enhance the bandwidth. The cutoff frequency (fc of the proposed lowpass filter is 1.09 GHz. The rejection band¬width of the filter covers the entire ultra wideband spec¬trum. Hence the spurious passband suppression is achieved up to 10 fc. The designed filter has been fabri¬cated and validated by experimental results

  15. Hong's grading for evaluating anterior chamber angle width.

    Science.gov (United States)

    Kim, Seok Hwan; Kang, Ja Heon; Park, Ki Ho; Hong, Chul

    2012-11-01

    To compare Hong's grading method with anterior segment optical coherence tomography (AS-OCT), gonioscopy, and the dark-room prone-position test (DRPT) for evaluating anterior chamber width. The anterior chamber angle was graded using Hong's grading method, and Hong's angle width was calculated from the arctangent of Hong's grades. The correlation between Hong's angle width and AS-OCT parameters was analyzed. The area under the receiver operating characteristic curve (AUC) for Hong's grading method when discriminating between narrow and open angles as determined by gonioscopy was calculated. Correlation analysis was performed between Hong's angle width and intraocular pressure (IOP) changes determined by DRPT. A total of 60 subjects were enrolled. Of these subjects, 53.5 % had a narrow angle. Hong's angle width correlated significantly with the AS-OCT parameters (r = 0.562-0.719, P < 0.01). A Bland-Altman plot showed relatively good agreement between Hong's angle width and the angle width obtained by AS-OCT. The ability of Hong's grading method to discriminate between open and narrow angles was good (AUC = 0.868, 95 % CI 0.756-0.942). A significant linear correlation was found between Hong's angle width and IOP change determined by DRPT (r = -0.761, P < 0.01). Hong's grading method is useful for detecting narrow angles. Hong's grading correlated well with AS-OCT parameters and DRPT.

  16. An Extended Octagonal Ring Dynamometer for Measurement of ...

    African Journals Online (AJOL)

    The analysis, design, construction, evaluation and use of an extended octagonal ring dynamometer for measurement of draught, vertical force and moment on a simple tillage tool are presented. The dynamometer was used to measure tool forces as functions of depth, rake angle and speed, for a wide plane blade.

  17. Imaging electron wave functions inside open quantum rings.

    Science.gov (United States)

    Martins, F; Hackens, B; Pala, M G; Ouisse, T; Sellier, H; Wallart, X; Bollaert, S; Cappy, A; Chevrier, J; Bayot, V; Huant, S

    2007-09-28

    Combining scanning gate microscopy (SGM) experiments and simulations, we demonstrate low temperature imaging of the electron probability density |Psi|(2)(x,y) in embedded mesoscopic quantum rings. The tip-induced conductance modulations share the same temperature dependence as the Aharonov-Bohm effect, indicating that they originate from electron wave function interferences. Simulations of both |Psi|(2)(x,y) and SGM conductance maps reproduce the main experimental observations and link fringes in SGM images to |Psi|(2)(x,y).

  18. Longitudinal changes of angle configuration in primary angle-closure suspects: the Zhongshan Angle-Closure Prevention Trial.

    Science.gov (United States)

    Jiang, Yuzhen; Chang, Dolly S; Zhu, Haogang; Khawaja, Anthony P; Aung, Tin; Huang, Shengsong; Chen, Qianyun; Munoz, Beatriz; Grossi, Carlota M; He, Mingguang; Friedman, David S; Foster, Paul J

    2014-09-01

    To determine longitudinal changes in angle configuration in the eyes of primary angle-closure suspects (PACS) treated by laser peripheral iridotomy (LPI) and in untreated fellow eyes. Longitudinal cohort study. Primary angle-closure suspects aged 50 to 70 years were enrolled in a randomized, controlled clinical trial. Each participant was treated by LPI in 1 randomly selected eye, with the fellow eye serving as a control. Angle width was assessed in a masked fashion using gonioscopy and anterior segment optical coherence tomography (AS-OCT) before and at 2 weeks, 6 months, and 18 months after LPI. Angle width in degrees was calculated from Shaffer grades assessed under static gonioscopy. Angle configuration was also evaluated using angle opening distance (AOD250, AOD500, AOD750), trabecular-iris space area (TISA500, TISA750), and angle recess area (ARA) measured in AS-OCT images. No significant difference was found in baseline measures of angle configuration between treated and untreated eyes. At 2 weeks after LPI, the drainage angle on gonioscopy widened from a mean of 13.5° at baseline to a mean of 25.7° in treated eyes, which was also confirmed by significant increases in all AS-OCT angle width measures (Pgonioscopy (P = 0.18), AOD250 (P = 0.167) and ARA (P = 0.83). In untreated eyes, angle width consistently decreased across all follow-up visits after LPI, with a more rapid longitudinal decrease compared with treated eyes (P values for all variables ≤0.003). The annual rate of change in angle width was equivalent to 1.2°/year (95% confidence interval [CI], 0.8-1.6) in treated eyes and 1.6°/year (95% CI, 1.3-2.0) in untreated eyes (P<0.001). Angle width of treated eyes increased markedly after LPI, remained stable for 6 months, and then decreased significantly by 18 months after LPI. Untreated eyes experienced a more consistent and rapid decrease in angle width over the same time period. Copyright © 2014 American Academy of Ophthalmology. Published by

  19. Evalutation of efficiency of dynamic laser magnetic stimulation of eye drainage system of patients with open angle glaucomatosis

    Directory of Open Access Journals (Sweden)

    Sidelnikova V.S.

    2014-06-01

    Full Text Available The purpose of the study is to develop a comprehensive treatment aimed at improving uveoscleral outflow in the application of dynamic laser magnetic stimulation of the drainage system of the eye and evaluation of its effectiveness in treating patients with primary open-angle glaucoma (POAG. Material. 106 patients diagnosed POAG I, II, III stages were examined. Group 1 consisted of 62 patients treated with medical therapy and dynamic laser magnetic stimulation of the drainage system of the eye using the "AMO-ATOS-ICL", produced by JSC "TRIMA", Saratov. Group 2 consisted of 64 patients who received only medical therapy. Comprehensive survey including standard eye examination, static perimetry, visual evoked potentials study, the study of intraocular blood flow was conducted to all patients. Analysis of the results of the complex therapeutic effects showed that as the result of treatment 73% of patients had a decrease of intraocular pressure and the ease factor outflow increase. 52% of patients had a decrease in the number and area of relative. 63% of patients had activation of intraocular blood flow. These indices remained stable for three months. Conclusion. The treatment with the technique of dynamic laser magnetic stimulation of the drainage system of the eye of patients with primary open-angle glaucoma leads to lower intraocular pressure, and to the improvement of dopple-rographic and perimetric indications.

  20. A New Role for CO2: Controlling Agent of the Anionic Ring-Opening Polymerization of Cyclic Esters

    KAUST Repository

    Varghese, Jobi K.

    2017-08-15

    Conventional anionic ring-opening of polymerization (AROP) of cyclic esters suffers from the nonselective and concomitant attack of the monomer and of the polymer chains by the growing active species, which results in polyester samples with uncontrolled molar masses and broad polydispersity due to the competition between propagation and transesterification reactions. In this report, we describe a new AROP system mediated by a controlled amount of CO2 which prevents transesterification reactions from occurring. Using lithium monomethyl diethylene glycoxide (MEEOLi) as initiator and 1.5 equiv of CO2, ε-caprolactone could be polymerized under truly “living” conditions in dichloromethane (DCM) at 70 °C, as evidenced by the control of molar masses, the narrow polydispersity indexes (Mn up to ∼40 kg/mol, Đ < 1.16), and also successful chain extension experiments. Lithium carbonate used as initiator in the presence of 0.5 equiv of CO2 afforded similar polymerization results. Experiments carried out with other alkoxide salts and solvents demonstrate that CO2 is indispensable as well as lithium and noncoordinating solvents for the suppression of transesterifications. A similar strategy was applied for the AROP of l-lactide (LLA). At −20 °C, LLA could be polymerized under living conditions with undetectable level of transesterification as demonstrated by MALDI-ToF analysis. To account for the polymerization mechanism occurring in the presence of a slight excess of CO2, we resorted to computational studies. It appears that a fast equilibrium takes place between two tetrameric aggregates, one dormant comprising four carbonates (RCO3Li)4, and an active one involving three carbonates and one alkoxide (RCO3Li)3(ROLi). The latter is shown to selectively ring-open cyclic ester without indulging in transesterifications like (ROLi)4 precursors.

  1. A New Role for CO2: Controlling Agent of the Anionic Ring-Opening Polymerization of Cyclic Esters

    KAUST Repository

    Varghese, Jobi K.; Goncalves, Theo; Huang, Kuo-Wei; Hadjichristidis, Nikolaos; Gnanou, Yves; Feng, Xiaoshuang

    2017-01-01

    Conventional anionic ring-opening of polymerization (AROP) of cyclic esters suffers from the nonselective and concomitant attack of the monomer and of the polymer chains by the growing active species, which results in polyester samples with uncontrolled molar masses and broad polydispersity due to the competition between propagation and transesterification reactions. In this report, we describe a new AROP system mediated by a controlled amount of CO2 which prevents transesterification reactions from occurring. Using lithium monomethyl diethylene glycoxide (MEEOLi) as initiator and 1.5 equiv of CO2, ε-caprolactone could be polymerized under truly “living” conditions in dichloromethane (DCM) at 70 °C, as evidenced by the control of molar masses, the narrow polydispersity indexes (Mn up to ∼40 kg/mol, Đ < 1.16), and also successful chain extension experiments. Lithium carbonate used as initiator in the presence of 0.5 equiv of CO2 afforded similar polymerization results. Experiments carried out with other alkoxide salts and solvents demonstrate that CO2 is indispensable as well as lithium and noncoordinating solvents for the suppression of transesterifications. A similar strategy was applied for the AROP of l-lactide (LLA). At −20 °C, LLA could be polymerized under living conditions with undetectable level of transesterification as demonstrated by MALDI-ToF analysis. To account for the polymerization mechanism occurring in the presence of a slight excess of CO2, we resorted to computational studies. It appears that a fast equilibrium takes place between two tetrameric aggregates, one dormant comprising four carbonates (RCO3Li)4, and an active one involving three carbonates and one alkoxide (RCO3Li)3(ROLi). The latter is shown to selectively ring-open cyclic ester without indulging in transesterifications like (ROLi)4 precursors.

  2. Strategies to Fabricate Polypeptide-Based Structures via Ring-Opening Polymerization of N-Carboxyanhydrides

    Directory of Open Access Journals (Sweden)

    Carmen M. González-Henríquez

    2017-10-01

    Full Text Available In this review, we provide a general and clear overview about the different alternatives reported to fabricate a myriad of polypeptide architectures based on the ring-opening polymerization of N-carbonyanhydrides (ROP NCAs. First of all, the strategies for the preparation of NCA monomers directly from natural occurring or from modified amino acids are analyzed. The synthetic alternatives to prepare non-functionalized and functionalized NCAs are presented. Protection/deprotection protocols, as well as other functionalization chemistries are discussed in this section. Later on, the mechanisms involved in the ROP NCA polymerization, as well as the strategies developed to reduce the eventually occurring side reactions are presented. Finally, a general overview of the synthetic strategies described in the literature to fabricate different polypeptide architectures is provided. This part of the review is organized depending on the complexity of the macromolecular topology prepared. Therefore, linear homopolypeptides, random and block copolypeptides are described first. The next sections include cyclic and branched polymers such as star polypeptides, polymer brushes and highly branched structures including arborescent or dendrigraft structures.

  3. Mediterranean diet adherence by patients with primary open angle glaucoma.

    Science.gov (United States)

    Abreu-Reyes, J A; Álvarez-Luis, D; Arteaga-Hernández, V; Sánchez-Mendez, M; Abreu-González, R

    2017-08-01

    To study the adherence to the Mediterranean diet in patients affected by primary open angle glaucoma (POAG). An observational study was conducted to assess the adherence to the Mediterranean diet in patients affected by POAG, and who attended the Ophthalmology Department of the Canary Islands University Hospital. The study included completing a 14-item questionnaire validated by the PREDIMED Study, in person or by telephone. A total of 100 questionnaires were completed successfully by 50 males and 50 females. The mean age was 69.58 years for the males and 67.42 years for women. The men had more comorbidities than women (tobacco 14 vs. 3%), arterial hypertension, and diabetes (30 vs. 28%, and 16 vs. 6%, respectively). Adherence to the Mediterranean diet in males, was low in 9 patients (18%), moderate in 37 (74%), and high in 4 (8%) cases. In women adherence was low in 14 patients (28%), moderate in 34 (68%), and high in 2 (6%) cases. The overall adhesion to the Mediterranean diet is low in 23%, moderate in 71% and high in 6% of the cases. Patients who are affected by POAG have moderate adherence to the Mediterranean diet. Copyright © 2017 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. High pressure photoinduced ring opening of benzene

    International Nuclear Information System (INIS)

    Ciabini, Lucia; Santoro, Mario; Bini, Roberto; Schettino, Vincenzo

    2002-01-01

    The chemical transformation of crystalline benzene into an amorphous solid (a-C:H) was induced at high pressure by employing laser light of suitable wavelengths. The reaction was forced to occur at 16 GPa, well below the pressure value (23 GPa) where the reaction normally occurs. Different laser sources were used to tune the pumping wavelength into the red wing of the first excited singlet state S 1 ( 1 B 2u ) absorption edge. Here the benzene ring is distorted, presenting a greater flexibility which makes the molecule unstable at high pressure. The selective pumping of the S 1 level, in addition to structural considerations, was of paramount importance to clarify the mechanism of the reaction

  5. Evaluation of the anterior chamber angle in Asian Indian eyes by ultrasound biomicroscopy and gonioscopy.

    Science.gov (United States)

    Kaushik, Sushmita; Jain, Rajeev; Pandav, Surinder Singh; Gupta, Amod

    2006-09-01

    To compare the ultrasound biomicroscopic measurement of the anterior chamber angle in Asian Indian eyes, with the angle width estimated by gonioscopy. Patients with open and closed angles attending a glaucoma clinic were recruited for the study. Temporal quadrants of the angles of patients were categorized by gonioscopy as Grade 0 to Grade 4, using Shaffer's classification. These angles were quantified by ultrasound biomicroscopy (UBM) using the following biometric characteristics: Angle opening distance at 250 micro (AOD 250) and 500 micro (AOD 500) from the scleral spur and trabecular meshwork-ciliary process distance (TCPD). The angles were further segregated as "narrow angles" (Schaffer's Grade 2 or less) and "open angles" (Schaffer's Grade 3 and 4). The UBM measurements were computed in each case and analyzed in relation to the gonioscopic angle evaluation. One hundred and sixty three eyes of 163 patients were analyzed. One hundred and six eyes had "narrow angles" and 57 eyes had "open angles" on gonioscopy. There was a significant difference among the mean UBM measurements of each angle grade estimated by gonioscopy (P gonioscopy grades was significant at the 0.01 level. The mean AOD 250, AOD 500 and TCPD in narrow angles were 58+/-49 micro, 102+/-84 micro and 653+/-124 respectively, while it was 176+/-47 micro, 291+/-62 micro and 883+/-94 micro in eyes with open angles (P gonioscopy correlated significantly with the angle dimensions measured by UBM. Gonioscopy, though a subjective test, is a reliable method for estimation of the angle width.

  6. Laparoscopic appendicectomy using endo-ring applicator and fallope rings

    International Nuclear Information System (INIS)

    Ali, Iyoob V; Maliekkal, Joji I

    2009-01-01

    Wider adoption of laparoscopic appendicectomy (LA) is limited by problems in securing the appendiceal base as well as the cost and the duration compared with the open procedure. The objective of this study was to assess the feasibility and efficacy of a new method for securing the appendiceal base in LA, so as to make the entire procedure simpler and cheaper, and hence, more popular. Twenty-five patients who were candidates for appendicectomy (emergency as well as elective) and willing for the laparoscopic procedure were selected for this study. Ports used were 10 mm at the umbilicus, 5 mm at the lower right iliac fossa, and 10 mm at the left iliac fossa. Extremely friable, ruptured, or turgid organs of diameters larger than 8 mm were excluded from the study. The mesoappendix was divided close to the appendix by diathermy. Fallope rings were applied to the appendiceal base using a special ring applicator, and the appendix was divided and extracted through the lumen of the applicator. The procedure was successful in 23 (92%) cases, and the mean duration of the procedure was 20 minutes (15-32 minutes). There were no procedural complications seen during a median follow-up of two weeks. The equipment and rings were cheaper when compared with that of the standard methods of securing the base of the appendix. LA using fallope rings is a safe, simple, easy-to-learn, and economically viable method. (author)

  7. Factors influencing left ventricular outflow tract obstruction following a mitral valve-in-valve or valve-in-ring procedure, part 1.

    Science.gov (United States)

    Bapat, Vinnie; Pirone, Francesco; Kapetanakis, Stam; Rajani, Ronak; Niederer, Steven

    2015-10-01

    To determine the factors influencing left ventricular outflow tract (LVOT) area reduction after a mitral valve-in-valve (VIV) or a valve-in-ring (VIR) procedure. Transcatheter heart valves (THVs) are increasingly used in performing a VIV or a VIR procedure in high-risk patients. Although less invasive, a potential complication is LVOT obstruction. However, the factors predisposing to LVOT obstruction are ill defined. To understand the effects of the various factors, the study was carried out in three parts: To understand the effect of VIV and VIR on reduction in LVOT area with special attention to different surgical heart valve (SHV) orientations and depth of THV implant. This was carried out in porcine and cadaver hearts. To quantify aorto-mitral-annular (AMA) angle in 20 patients with or without mitral disease and to derive a static computational model to predict LVOT obstruction. To study the effect of SHV design on LVOT obstruction after VIV. This was carried out as a bench test. LVOT area reduction was similar after VIV irrespective of orientation of the mitral SHV implantation as it pinned open the SHV leaflets. Similar effect was seen after VIR. The degree of LVOT obstruction was partly determined by AMAangle and was inversely proportional. SHV design, ring design, and depth of SPAIEN XT implantation also had effect on LVOT obstruction. A possibility of LVOT obstruction should be considered when performing a VIV and VIR procedure. Type of SHV, flexible ring, less obtuse AMA angle, and depth of SAPIEN XT implant can influence the risk. © 2015 Wiley Periodicals, Inc.

  8. Recent Developments of Versatile Photoinitiating Systems for Cationic Ring Opening Polymerization Operating at Any Wavelengths and under Low Light Intensity Sources

    Directory of Open Access Journals (Sweden)

    Jacques Lalevée

    2015-04-01

    Full Text Available Photoinitiators (PI or photoinitiating systems (PIS usable in light induced cationic polymerization (CP and free radical promoted cationic polymerization (FRPCP reactions (more specifically for cationic ring opening polymerization (ROP together with the involved mechanisms are briefly reviewed. The recent developments of novel two- and three-component PISs for CP and FRPCP upon exposure to low intensity blue to red lights is emphasized in details. Examples of such reactions under various experimental conditions are provided.

  9. Ocular Biometrics of Myopic Eyes With Narrow Angles.

    Science.gov (United States)

    Chong, Gabriel T; Wen, Joanne C; Su, Daniel Hsien-Wen; Stinnett, Sandra; Asrani, Sanjay

    2016-02-01

    The purpose of this study was to compare the ocular biometrics between myopic patients with and without narrow angles. Patients with a stable myopic refraction (myopia worse than -1.00 D spherical equivalent) were prospectively recruited. Angle status was assessed using gonioscopy and biometric measurements were performed using an anterior segment optical coherence tomography and an IOLMaster. A total of 29 patients (58 eyes) were enrolled with 13 patients (26 eyes) classified as having narrow angles and 16 patients (32 eyes) classified as having open angles. Baseline demographics of age, sex, and ethnicity did not differ significantly between the 2 groups. The patients with narrow angles were on average older than those with open angles but the difference did not reach statistical significance (P=0.12). The central anterior chamber depth was significantly less in the eyes with narrow angles (P=0.05). However, the average lens thickness, although greater in the eyes with narrow angles, did not reach statistical significance (P=0.10). Refractive error, axial lengths, and iris thicknesses did not differ significantly between the 2 groups (P=0.32, 0.47, 0.15). Narrow angles can occur in myopic eyes. Routine gonioscopy is therefore recommended for all patients regardless of refractive error.

  10. Recent applications of ring-rearrangement metathesis in organic synthesis

    Directory of Open Access Journals (Sweden)

    Sambasivarao Kotha

    2015-10-01

    Full Text Available Ring-rearrangement metathesis (RRM involves multiple metathesis processes such as ring-opening metathesis (ROM/ring-closing metathesis (RCM in a one-pot operation to generate complex targets. RRM delivers complex frameworks that are difficult to assemble by conventional methods. The noteworthy point about this type of protocol is multi-bond formation and it is an atom economic process. In this review, we have covered literature that appeared during the last seven years (2008–2014.

  11. Novel and known MYOC exon 3 mutations in an admixed Peruvian primary open-angle glaucoma population.

    Science.gov (United States)

    Mendoza-Reinoso, Veronica; Patil, Teja S; Guevara-Fujita, Maria L; Fernández, Silvia; Vargas, Enrique; Castillo-Herrera, Wilder; Perez-Grossmann, Rodolfo; Lizaraso-Caparó, Frank; Richards, Julia E; Fujita, Ricardo

    2012-01-01

    The aim of this study was to characterize a representative sample of the Peruvian population suffering open-angle glaucoma (OAG) with respect to the myocilin gene (MYOC) mutations, glaucoma phenotype, and ancestry for future glaucoma risk assessment. DNA samples from 414 unrelated Peruvian subjects, including 205 open-angle glaucoma cases (10 juvenile glaucoma [JOAG], 19 normal-tension glaucoma [NTG], and 176 POAG) and 209 randomly sampled controls, were screened for nucleotide changes in MYOC exon 3 by conformational sensitive gel electrophoresis (CSGE) and mutation screening. We identified a probable causative novel MYOC missense mutation, Gly326Ser, in one POAG case and found a consistent genotype-phenotype correlation in eight of his relatives. We also found the known causative MYOC mutation Trp286Arg in one JOAG case and one POAG case. A known causative single base MYOC deletion, T1357, was found in one POAG case. Two previously reported silent polymorphisms, Thr325Thr and Tyr347Tyr, were found in both the case and the control populations. A novel missense variant, Met476Arg, was identified in two unrelated controls. The screening of exon 3 of MYOC in a representative sample of 205 independent POAG patients from Peru and 209 matched controls identified novel and previously reported mutations (both pathogenic and nonpathogenic) from other global regions. These results reflect the complex admixture of Amerindian and Old World ancestry in urban populations of Latin America, in general, and in Peru, in particular. It will be important to gather information about the ancestral origin of MYOC and other POAG gene mutations to develop screening panels and risk assessment for POAG in Peru.

  12. Preservative-free versus preserved latanoprost eye drops in patients with open-angle glaucoma or ocular hypertension.

    Science.gov (United States)

    Aptel, Florent; Choudhry, Reena; Stalmans, Ingeborg

    2016-08-01

    This study compared the efficacy, safety, and pharmacokinetics of a preservative-free latanoprost formulation to an established, benzalkonium chloride (BAK) containing formulation for the treatment of open-angle glaucoma or ocular hypertension. This was a phase II, randomized, cross-over, investigator-masked, multi-center, pilot study (NCT01494753). A total of 30 untreated adult patients (aged ≥18 years) with primary open angle glaucoma, pseudo-exfoliative glaucoma, pigmentary glaucoma, or ocular hypertension received either preservative-free or preserved latanoprost once daily in both eyes for 6 weeks, before crossing over to receive the other treatment. Efficacy (intraocular pressure [IOP] at 8 am, midday, 4 pm and 8 pm, and global efficacy assessment by investigator), safety (adverse events, ocular symptoms and global tolerance, slit lamp examination, funduscopy, visual field examination, visual acuity, and heart rate), and pharmacokinetics were assessed at Days 0, 42, and 84. Both treatments resulted in a reduction in IOP that was similar for the preservative-free and the preserved formulation at all time points. Similarly, the overall diurnal reduction was similar in both groups (6.3 mmHg [27.9% reduction] and 6.4 mmHg [28.1% reduction] for preserved and preservative-free latanoprost, respectively). There were no differences in global efficacy assessment or in the safety and tolerance of each treatment. Systemic concentrations of latanoprost were very low; AUC0-30 and Cmax were lower and tmax was longer for preservative-free latanoprost. Preservative-free latanoprost showed similar efficacy at all time points compared to BAK preservative containing formulation, with no difference in tolerance, allowing progression to phase III clinical development.

  13. Infrared Spectroscopy Beamline Based on a Tabletop Storage Ring

    OpenAIRE

    Haque, Md. Monirul; Moon, Ahsa; Yamada, Hironari

    2012-01-01

    An optical beamline dedicated to the infrared (IR) spectroscopy has been constructed at MIRRORCLE, a tabletop storage ring. The beamline has been designed for the use of infrared synchrotron radiation (IRSR) emitted from a bending magnet of 156 mm bending radius with the acceptance angle of 355(H) × 138(V) mrad to obtain high flux. The IR emission is forced by an exactly circular optics, named photon storage ring (PhSR), placed around the electron orbit and is collected by a “magic mirror” as...

  14. Phacoemulsification with intraocular lens implantation in primary angle-closure suspect, primary angle-closure and primary angle-closure glaucoma with cataract

    Directory of Open Access Journals (Sweden)

    Kun Zeng

    2013-08-01

    Full Text Available AIM: To evaluate the features and clinical outcomes of cataract extraction by phacoemulsification with intraocular lens implantation in primary angle-closure suspect(PACS, primary angle-closure(PACand primary angle-closure glaucoma(PACGwith cataract.METHODS:Phacoemulsification with intraocular lens implantation was performed on 86 cases(86 eyesdiagnosed as PACS, PAC and PACG co-existing cataract from January to December 2012. All cases were followed up for 3 months to 1 year. Pre-operative and post-operative visual acuity, intraocular pressure(IOP, gonioscopy, ultrasound biomicroscopy(UBM, visual field and usage of anti-glaucomaous eye drops were recorded.RESULTS:Zonular dialysis existed in 19 eyes(22%. The post-operative visual acuity improved in 84 eyes(98%. The post-operative visual acuity was CONCLUSION: PACS, PAC and PACG co-existing zonular dialysis is common. Phacoemulsification with IOL implantation can reduce IOP, deepen anterior chamber and open angle.

  15. Small Angle X-Ray Scattering Detector

    Energy Technology Data Exchange (ETDEWEB)

    Hessler, Jan P.

    2004-06-15

    A detector for time-resolved small-angle x-ray scattering includes a nearly constant diameter, evacuated linear tube having an end plate detector with a first fluorescent screen and concentric rings of first fiber optic bundles for low angle scattering detection and an annular detector having a second fluorescent screen and second fiber optic bundles concentrically disposed about the tube for higher angle scattering detection. With the scattering source, i.e., the specimen under investigation, located outside of the evacuated tube on the tube's longitudinal axis, scattered x-rays are detected by the fiber optic bundles, to each of which is coupled a respective photodetector, to provide a measurement resolution, i.e., dq/q, where q is the momentum transferred from an incident x-ray to an x-ray scattering specimen, of 2% over two (2) orders of magnitude in reciprocal space, i.e., qmax/qmin approx=lO0.

  16. Multi-Angle Snowflake Camera Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Stuefer, Martin [Univ. of Alaska, Fairbanks, AK (United States); Bailey, J. [Univ. of Alaska, Fairbanks, AK (United States)

    2016-07-01

    The Multi-Angle Snowflake Camera (MASC) takes 9- to 37-micron resolution stereographic photographs of free-falling hydrometers from three angles, while simultaneously measuring their fall speed. Information about hydrometeor size, shape orientation, and aspect ratio is derived from MASC photographs. The instrument consists of three commercial cameras separated by angles of 36º. Each camera field of view is aligned to have a common single focus point about 10 cm distant from the cameras. Two near-infrared emitter pairs are aligned with the camera’s field of view within a 10-angular ring and detect hydrometeor passage, with the lower emitters configured to trigger the MASC cameras. The sensitive IR motion sensors are designed to filter out slow variations in ambient light. Fall speed is derived from successive triggers along the fall path. The camera exposure times are extremely short, in the range of 1/25,000th of a second, enabling the MASC to capture snowflake sizes ranging from 30 micrometers to 3 cm.

  17. Inter-tetrahedra bond angle of permanently densified silicas extracted from their Raman spectra

    International Nuclear Information System (INIS)

    Hehlen, B

    2010-01-01

    Relative Raman scattering intensities are obtained in three samples of vitreous silica of increasing density. The variation of the intensity upon densification is very different for bending and stretching modes. For the former we find a Raman coupling-to-light coefficient C B ∝ω 2 . A comparative intensity and frequency dependence of the Raman spectral lines in the three glasses is performed. Provided the Raman spectra are normalized by C B , there exists a simple relation between the Si-O-Si bond angle and the frequency of all O-bending motions, including those of fourfold (n = 4) and threefold (n = 3) rings. For 20% densification we find a reduction of ∼5.7 deg. of the maximum of the network angle distribution, a value in very close agreement with previous NMR experiments. The threefold and fourfold rings are weakly perturbed by the densification, with a bond angle reduction of ∼0.5 deg. for the former.

  18. A proposal of an open PET geometry

    Energy Technology Data Exchange (ETDEWEB)

    Yamaya, Taiga [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555 (Japan); Inaniwa, Taku [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Minohara, Shinichi [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Yoshida, Eiji [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555 (Japan); Inadama, Naoko [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555 (Japan); Nishikido, Fumihiko [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555 (Japan); Shibuya, Kengo [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555 (Japan); Lam, Chih Fung [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555 (Japan); Murayama, Hideo [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555 (Japan)

    2008-02-07

    The long patient port of a PET scanner tends to put stress on patients, especially patients with claustrophobia. It also prevents doctors and technicians from taking care of patients during scanning. In this paper, we proposed an 'open PET' geometry, which consists of two axially separated detector rings. A long and continuous field-of-view (FOV) including a 360 deg. opened gap between two detector rings can be imaged enabling a fully 3D image reconstruction of all the possible lines-of-response. The open PET will become practical if iterative image reconstruction methods are applied even though image reconstruction of the open PET is analytically an incomplete problem. First we implemented a 'masked' 3D ordered subset expectation maximization (OS-EM) in which the system matrix was obtained from a long 'gapless' scanner by applying a mask to detectors corresponding to the open space. Next, in order to evaluate imaging performance of the proposed open PET geometry, we simulated a dual HR+ scanner (ring diameter of D = 827 mm, axial length of W = 154 mm x 2) separated by a variable gap. The gap W was the maximum limit to have axially continuous FOV of 3W though the maximum diameter of FOV at the central slice was limited to D/2. Artifacts, observed on both sides of the open space when the gap exceeded W, were effectively reduced by inserting detectors partially into unnecessary open spaces. We also tested the open PET geometry using experimental data obtained by the jPET-D4. The jPET-D4 is a prototype brain scanner, which has 5 rings of 24 detector blocks. We simulated the open jPET-D4 with a gap of 66 mm by eliminating 1 block-ring from experimental data. Although some artifacts were seen at both ends of the opened gap, very similar images were obtained with and without the gap. The proposed open PET geometry is expected to lead to realization of in-beam PET, which is a method for an in situ monitoring of charged particle therapy, by

  19. Robust gap repair in the contractile ring ensures timely completion of cytokinesis.

    OpenAIRE

    Silva, AM; Osório, DS; Pereira, AJ; Maiato, H; Pinto, IM; Rubinstein, B; Gassmann, R; Telley, IA; Carvalho, AX

    2016-01-01

    Cytokinesis in animal cells requires the constriction of an actomyosin contractile ring, whose architecture and mechanism remain poorly understood. We use laser microsurgery to explore the biophysical properties of constricting rings in Caenorhabditis elegans embryos. Laser cutting causes rings to snap open. However, instead of disintegrating, ring topology recovers and constriction proceeds. In response to severing, a finite gap forms and is repaired by recruitment of new material in an acti...

  20. Ring-shaped lesions in the CT scan

    International Nuclear Information System (INIS)

    Kazner, E.; Steinhoff, H.; Wende, S.; Mauersberger, W.

    1978-01-01

    Computerised tomography has really opened new dimensions for the diagnosis of various intracranial space-occupying lesions. However, during the last years we had to learn how difficult it can be to evaluate a certain CT finding correctly. Especially the group of ring-type lesions still pose some unsolved problems even if clinical information available in the individual case is considered. The ring blush is a nonspecific finding which occurs in primary and metastatic neoplasms, abscess, infarction, certain stages of intracerebral hematomas and even after neurosurgical operations. The ring blush is caused partly by breakdown of the blood brain barrier, partly by hypervascular pathologic tissue or by both factors. (orig.) [de

  1. Longitudinal Changes of Angle Configuration in Primary Angle-Closure Suspects

    Science.gov (United States)

    Jiang, Yuzhen; Chang, Dolly S.; Zhu, Haogang; Khawaja, Anthony P.; Aung, Tin; Huang, Shengsong; Chen, Qianyun; Munoz, Beatriz; Grossi, Carlota M.

    2015-01-01

    Objective To determine longitudinal changes in angle configuration in the eyes of primary angle-closure suspects (PACS) treated by laser peripheral iridotomy (LPI) and in untreated fellow eyes. Design Longitudinal cohort study. Participants Primary angle-closure suspects aged 50 to 70 years were enrolled in a randomized, controlled clinical trial. Methods Each participant was treated by LPI in 1 randomly selected eye, with the fellow eye serving as a control. Angle width was assessed in a masked fashion using gonioscopy and anterior segment optical coherence tomography (AS-OCT) before and at 2 weeks, 6 months, and 18 months after LPI. Main Outcome Measures Angle width in degrees was calculated from Shaffer grades assessed under static gonioscopy. Angle configuration was also evaluated using angle opening distance (AOD250, AOD500, AOD750), trabecular-iris space area (TISA500, TISA750), and angle recess area (ARA) measured in AS-OCT images. Results No significant difference was found in baseline measures of angle configuration between treated and untreated eyes. At 2 weeks after LPI, the drainage angle on gonioscopy widened from a mean of 13.5° at baseline to a mean of 25.7° in treated eyes, which was also confirmed by significant increases in all AS-OCT angle width measures (Pgonioscopy (P = 0.18), AOD250 (P = 0.167) and ARA (P = 0.83). In untreated eyes, angle width consistently decreased across all follow-up visits after LPI, with a more rapid longitudinal decrease compared with treated eyes (P values for all variables ≤0.003). The annual rate of change in angle width was equivalent to 1.2°/year (95% confidence interval [CI], 0.8–1.6) in treated eyes and 1.6°/year (95% CI, 1.3–2.0) in untreated eyes (P<0.001). Conclusions Angle width of treated eyes increased markedly after LPI, remained stable for 6 months, and then decreased significantly by 18 months after LPI. Untreated eyes experienced a more consistent and rapid decrease in angle width over the

  2. Evaluation of the anterior chamber angle in Asian Indian eyes by ultrasound biomicroscopy and gonioscopy

    Directory of Open Access Journals (Sweden)

    Kaushik Sushmita

    2006-01-01

    Full Text Available Purpose: To compare the ultrasound biomicroscopic measurement of the anterior chamber angle in Asian Indian eyes, with the angle width estimated by gonioscopy. Materials and Methods: Participants: Patients with open and closed angles attending a glaucoma clinic were recruited for the study. Observation Procedures: Temporal quadrants of the angles of patients were categorized by gonioscopy as Grade 0 to Grade 4, using Shaffer′s classification. These angles were quantified by ultrasound biomicroscopy (UBM using the following biometric characteristics: Angle opening distance at 250 µ (AOD 250 and 500 µ (AOD 500 from the scleral spur and trabecular meshwork-ciliary process distance (TCPD. The angles were further segregated as "narrow angles" (Schaffer′s Grade 2 or less and "open angles" (Schaffer′s Grade 3 and 4. Main Outcome Measures: The UBM measurements were computed in each case and analyzed in relation to the gonioscopic angle evaluation. Results: One hundred and sixty three eyes of 163 patients were analyzed. One hundred and six eyes had "narrow angles" and 57 eyes had "open angles" on gonioscopy. There was a significant difference among the mean UBM measurements of each angle grade estimated by gonioscopy ( P < 0.001. The Pearson correlation coefficient between all UBM parameters and gonioscopy grades was significant at the 0.01 level. The mean AOD 250, AOD 500 and TCPD in narrow angles were 58±49 µ, 102±84 µ and 653±124 respectively, while it was 176±47 µ, 291±62 µ and 883±94 µ in eyes with open angles ( P < 0.001 respectively. Conclusions: The angle width estimated by gonioscopy correlated significantly with the angle dimensions measured by UBM. Gonioscopy, though a subjective test, is a reliable method for estimation of the angle width.

  3. A pilot investigation to constrain the presence of ring systems around transiting exoplanets

    Science.gov (United States)

    Hatchett, W. Timothy; Barnes, Jason W.; Ahlers, John P.; MacKenzie, Shannon M.; Hedman, Matthew M.

    2018-04-01

    We demonstrate a process by which to evaluate the presence of large, Saturn-like ring systems around transiting extrasolar giant planets. We use extrasolar planet candidate KOI-422.01 as an example around which to establish limits on the presence of ring systems. We find that the spherical-planet (no-rings) fit matches the lightcurve of KOI-422.01 better than a lightcurve with a planet having obliquity angles 90°, 60°, 45°, or 20°. Hence we find no evidence for rings around KOI-422.01, but the methods that we have developed can be used for more comprehensive ring searches in the future. If the Hedman (2015) low-temperature rings hypothesis is correct, then the first positive detection of exorings might require transits of very long period ( ≳ 10 yr) giant planets outside their stars' ice lines.

  4. Experimental Study of Shock Generated Compressible Vortex Ring

    Science.gov (United States)

    Das, Debopam; Arakeri, Jaywant H.; Krothapalli, Anjaneyulu

    2000-11-01

    Formation of a compressible vortex ring and generation of sound associated with it is studied experimentally. Impulse of a shock wave is used to generate a vortex ring from the open end of a shock-tube. Vortex ring formation process has been studied in details using particle image Velocimetry (PIV). As the shock wave exits the tube it diffracts and expands. A circular vortex sheet forms at the edge and rolls up into a vortex ring. Far field microphone measurement shows that the acoustic pressure consists of a spike due to shock wave followed by a low frequency pressure wave of decaying nature, superimposed with high frequency pressure wave. Acoustic waves consist of waves due to expansion, waves formed in the tube during diaphragm breakage and waves associated with the vortex ring and shear-layer vortices. Unsteady evolution of the vortex ring and shear-layer vortices in the jet behind the ring is studied by measuring the velocity field using PIV. Corresponding vorticity field, circulation around the vortex core and growth rate of the vortex core is calculated from the measured velocity field. The velocity field in a compressible vortex ring differs from that of an incompressible ring due to the contribution from both shock and vortex ring.

  5. The influence of venous blood flow on the retinal ganglion cell complex in patients with primary open angle glaucoma

    Directory of Open Access Journals (Sweden)

    N. I. Kurysheva

    2014-07-01

    Full Text Available Purpose: To study the influence of venous blood flow on the ganglion cell complex (GCC in patients with preperimetric and perimetric open angle glaucoma.Methods: 74 patients were included in the research. 59 eyes and 62 eyes were diagnosed with preperimetric and perimetric open angle glaucoma respectively. The mean age was 56.5±10.5 years. 22 (12 female and 10 male healthy individuals constituted the control group. The ganglion cell complex and retinal nerve fibre layer were evaluated with the help of optical coherence tomography (RTVue-100 OCT, Optovue, Inc., Fremont, CA. Ocular blood flow was measured by Color Doppler Imaging (multifunctional VOLUSON 730 ProSystem. The statistical analysis included correlation between GCC and RNFL thickness in both glaucoma groups.Results: The results showed a statistically significant reduction of venous blood flow velocity in both glaucoma groups compared to the control group. No difference in venous blood flow parameters between two glaucoma groups was found, except resistance index, which was higher in perimetric group in comparison to preperimetric group. A correlation was also obtained between venous blood flow parameters and GCC and RNFL thickness in both glaucoma groups.Conclusion: Early GCC damage in glaucoma might occur due to venous blood flow reduction. This fact may be of great value in understanding glaucoma pathogenesis and search for novel treatment options.

  6. "APOPTOSIS COLOR." SCREENING STRATEGY FOR DIAGNOSIS EARLY STAGES OF PRIMARY OPEN-ANGLE GLAUCOMA

    Directory of Open Access Journals (Sweden)

    M. A. Kovalevskaya

    2017-01-01

    Full Text Available Purpose: to develop a screening strategy for the early diagnosis of primary open-angle glaucoma.Patients and Methods: 1 group — 250 patients with suspected glaucoma (42–75 years, 2 — 250 with the 1st stage primary open-angle glaucoma (42–61, 3 — 3,000 healthy persons (35 to 50. Surveys: visometry, tonometry iCare, biomicroscopy, gonioscopy, pachymeria, ophthalmoscopy with a high dioptric lens of 60 D, standard automated perimetry of the SITA-Standard and SITA-SWAP program, assessing the color sensitivity according to the Famsworth-Munsell 100 HueTes method.Results: 1 group — SITA-SWAP: MD -2,55±0,7 dB, PSD 2,46±1,15 dB. Mansell test: TES = 58.6±18.7 (p<0.05, average level of color recognition; mild deficiency of color vision — 41–100 TES; by the RGB system: colors of the first order; tone in RGB (0–239: blue — 160; HCV: blue — 240; range of wavelengths: blue — 440–485 nm; frequency: blue — 620–680 THz. 2 group — on SITA-SWAP: MD — 5,13±1,3 dB, PSD 2,58±0,9 dB. Mansell test: TES = 86,9±21,8; average level of color recognition; mild deficiency of color vision; single deviations in the system of blue (azure, blue, blue; color I order (blue, III order (blue, azure; tone in RGB — (0–239: blue (azure, blue — 140, blue — 160; HCV — blue (azure, blue — 210, blue — 240; range of wavelengths: 450–500 nm (blue — 485–500, blue — 440–485; frequencies: 600–680 THz (blue — 600–620, blue — 620–680. Control group — SITA-SWAP within the norm, Mansell test: TES = 40,1±17,3 (p<0.05, medium level of color recognition, lack of color vision absent / mild, single deviations.Conclusion: in patients with glaucoma suspicion, the score of errors was higher than in the control group with Munsell test. In patients with glaucoma, the number of errors is greater than in patients with suspected glaucoma, and 2.2 times higher than in the control group.

  7. A quantum dynamics study of the benzopyran ring opening guided by laser pulses

    Science.gov (United States)

    Saab, Mohamad; Doriol, Loïc Joubert; Lasorne, Benjamin; Guérin, Stéphane; Gatti, Fabien

    2014-10-01

    The ring-opening photoisomerization of benzopyran, which occurs via a photochemical route involving a conical intersection, has been studied with quantum dynamics calculations using the multi-configuration time-dependent Hartree method (MCTDH). We introduce a mechanistic strategy to control the conversion of benzopyran to merocyanine with laser pulses. We use a six-dimensional model developed in a previous work for the potential energy surfaces (PES) based on an extension of the vibronic-coupling Hamiltonian model (diabatization method by ansatz), which depends on the most active degrees of freedom. The main objective of these quantum dynamics simulations is to provide a set of strategies that could help experimentalists to control the photoreactivity vs. photostability ratio (selectivity). In this work we present: (i) a pump-dump technique used to control the photostability, (ii) a two-step strategy to enhance the reactivity of the system: first, a pure vibrational excitation in the electronic ground state that prepares the system and, second, an ultraviolet excitation that brings the system to the first adiabatic electronic state; (iii) finally the effect of a non-resonant pulse (Stark effect) on the dynamics.

  8. Cherenkov rings from aerogel detected by four large-area hybrid photodiodes

    International Nuclear Information System (INIS)

    Bellunato, T.; Braem, A.; Buzykaev, A.R.; Calvi, M.; Chesi, E.; Danilyuk, A.F.; Easo, S.; Jolly, S.; Joram, C.; Kravchenko, E.A.; Liko, D.; Matteuzzi, C.; Musy, M.; Negri, P.; Neufeld, N.; Onuchin, A.P.; Seguinot, J.; Wotton, S.

    2003-01-01

    We report on the results obtained using thick samples of silica aerogel as radiators for a Ring Imaging Cherenkov counter. Four large-diameter hybrid photodiodes with 2048 channels have been used as photon detectors. Pions and protons with momenta ranging from 6 to 10 GeV/c were separated and identified. The number of photoelectrons and the radius of the Cherenkov rings together with the Cherenkov angle resolution were measured. A comparison with a simulation program based on GEANT4 is discussed

  9. Influence of Contact Angle, Growth Angle and Melt Surface Tension on Detached Solidification of InSb

    Science.gov (United States)

    Wang, Yazhen; Regel, Liya L.; Wilcox, William R.

    2000-01-01

    We extended the previous analysis of detached solidification of InSb based on the moving meniscus model. We found that for steady detached solidification to occur in a sealed ampoule in zero gravity, it is necessary for the growth angle to exceed a critical value, the contact angle for the melt on the ampoule wall to exceed a critical value, and the melt-gas surface tension to be below a critical value. These critical values would depend on the material properties and the growth parameters. For the conditions examined here, the sum of the growth angle and the contact angle must exceed approximately 130, which is significantly less than required if both ends of the ampoule are open.

  10. Progression of visual field in patients with primary open-angle glaucoma - ProgF study 1.

    Science.gov (United States)

    Aptel, Florent; Aryal-Charles, Nishal; Giraud, Jean-Marie; El Chehab, Hussam; Delbarre, Maxime; Chiquet, Christophe; Romanet, Jean-Paul; Renard, Jean-Paul

    2015-12-01

    To evaluate the visual field rate of progression of patients with treated ocular hypertension (OHT) and primary open-angle glaucoma (POAG) in clinical practice, using the mean deviation (MD) and the visual field index (VFI). Non-interventional cohort study. From a large multicentre database representative of the French population, 441 eyes of 228 patients with treated OHT or POAG followed up at least 6 years with Humphrey 24.2 Sita-Standard visual field examination at least twice a year were identified. From initial data, eyes were classified in five groups: 121 with OHT, 188 with early glaucoma (MD greater than -6 dB), 45 with moderate glaucoma (MD -6 to -12 dB), 41 with advanced glaucoma (MD -12 to -18 dB) and 46 with severe glaucoma (MD less than -18 dB). Rate of progression during the follow-up period was calculated using the trend analysis of the Guided Progression Analysis software. The mean duration of follow-up was 8.4 ± 2.7 years and the mean number of visual field, 18.4 ± 3.5. In eyes with OHT, rate of progression was -0.09 dB/year (-0.17%VFI/year). In eyes with POAG, rate of progression was -0.32 dB/year (-0.83%VFI/year) in eyes with early glaucoma, -0.52 dB/year (-1.81%VFI/year) in moderate glaucoma, -0.54 dB/year (-2.35%VFI/year) in advanced glaucoma and -0.45 dB/year (-1.97%VFI/year) in severe glaucoma. In eyes with POAG, a significant progression (p open-angle glaucoma is a progressive disease in the majority of patients despite cautioned treatment and follow-up. The rate of progression varies greatly among subjects. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  11. Predictors of success in selective laser trabeculoplasty for primary open angle glaucoma in Chinese

    Directory of Open Access Journals (Sweden)

    Lee JW

    2014-09-01

    Full Text Available Jacky WY Lee,1,2 Catherine CL Liu,3 Jonathan CH Chan,4 Raymond LM Wong,5 Ian YH Wong,2 Jimmy SM Lai2 1The Department of Ophthalmology, Caritas Medical Centre, Hong Kong, SAR, People’s Republic of China; 2The Department of Ophthalmology, The University of Hong Kong, Hong Kong, SAR, People’s Republic of China; 3Department of Applied Mathematics, The Hong Kong Polytechnic University, Hong Kong, SAR, People’s Republic of China; 4The Department of Ophthalmology, Queen Mary Hospital, Hong Kong, SAR, People’s Republic of China; 5The Department of Ophthalmology and Visual Sciences, Hong Kong Eye Hospital, Hong Kong, SAR, People’s Republic of China Purpose: To determine the predictors of success for adjuvant selective laser trabeculoplasty (SLT in Chinese primary open angle glaucoma (POAG patients. Methods: This prospective study recruited Chinese subjects with unilateral or bilateral POAG currently taking medication to reduce intraocular pressure (IOP. All subjects received a single session of 360° SLT treatment and continued their medications for 1 month. SLT success was defined as IOP reduction ≥20% at 1 month. The following covariates were analyzed in both groups via univariate and multivariate analyses: age, sex, lens status, initial IOPs, post-SLT IOPs, number and type of medications, SLT shots and energy, and pre-SLT investigations.Results: In 51 eyes of 33 POAG subjects, the success rate of SLT was 47.1%. Certain groups of patients were associated with greater success using univariate analysis. These groups included the following: older age (coefficient =0.1; OR: 1.1; P=0.0003, a higher pre-SLT IOP (coefficient =0.3; OR: 1.3; P=0.0005, using four types of antiglaucoma medication (coefficient =2.1; OR: 8.4; P=0.005, a greater degree of spherical equivalent (coefficient =2.1; OR: 8.4; P=0.005, and the use of a topical carbonic anhydrase inhibitor (coefficient =1.7; OR: 6.0; P=0.003. None of the covariates were significant using

  12. Monitoring conical intersections in the ring opening of furan by attosecond stimulated X-ray Raman spectroscopy

    Directory of Open Access Journals (Sweden)

    Weijie Hua

    2016-03-01

    Full Text Available Attosecond X-ray pulses are short enough to capture snapshots of molecules undergoing nonadiabatic electron and nuclear dynamics at conical intersections (CoIns. We show that a stimulated Raman probe induced by a combination of an attosecond and a femtosecond pulse has a unique temporal and spectral resolution for probing the nonadiabatic dynamics and detecting the ultrafast (∼4.5 fs passage through a CoIn. This is demonstrated by a multiconfigurational self-consistent-field study of the dynamics and spectroscopy of the furan ring-opening reaction. Trajectories generated by surface hopping simulations were used to predict Attosecond Stimulated X-ray Raman Spectroscopy signals at reactant and product structures as well as representative snapshots along the conical intersection seam. The signals are highly sensitive to the changes in nonadiabatically coupled electronic structure and geometry.

  13. Efficient Diethylzinc/Gallic Acid and Diethylzinc/Gallic Acid Ester Catalytic Systems for the Ring-Opening Polymerization of rac-Lactide

    Directory of Open Access Journals (Sweden)

    Karolina Żółtowska

    2015-12-01

    Full Text Available Polylactide (PLA represents one of the most promising biomedical polymers due to its biodegradability, bioresorbability and good biocompatibility. This work highlights the synthesis and characterization of PLAs using novel diethylzinc/gallic acid (ZnEt2/GAc and diethylzinc/propyl gallate (ZnEt2/PGAc catalytic systems that are safe for human body. The results of the ring-opening polymerization (ROP of rac-lactide (rac-LA in the presence of zinc-based catalytic systems have shown that, depending on the reaction conditions, “predominantly isotactic”, disyndiotactic or atactic PLA can be obtained. Therefore, the controlled and stereoselective ROP of rac-LA is discussed in detail in this paper.

  14. Conference on Recent Advances in Commutative Ring and Module Theory & Conference on Rings and Polynomials

    CERN Document Server

    Frisch, Sophie; Glaz, Sarah; Tartarone, Francesca; Zanardo, Paolo

    2017-01-01

    This volume presents a collection of articles highlighting recent developments in commutative algebra and related non-commutative generalizations. It also includes an extensive bibliography and lists a substantial number of open problems that point to future directions of research in the represented subfields. The contributions cover areas in commutative algebra that have flourished in the last few decades and are not yet well represented in book form. Highlighted topics and research methods include Noetherian and non-Noetherian ring theory, module theory and integer-valued polynomials along with connections to algebraic number theory, algebraic geometry, topology and homological algebra. Most of the eighteen contributions are authored by attendees of the two conferences in commutative algebra that were held in the summer of 2016: “Recent Advances in Commutative Ring and Module Theory,” Bressanone, Italy; “Conference on Rings and Polynomials”  Graz, Austria. There is also a small collection of invite...

  15. Relating Trp-Glu dipeptide fluorescence to molecular conformation: the role of the discrete Chi 1 and Chi 2 angles.

    Science.gov (United States)

    Eisenberg, Azaria Solomon; Juszczak, Laura J

    2013-07-05

    Molecular dynamics (MD), coupled with fluorescence data for charged dipeptides of tryptophanyl glutamic acid (Trp-Glu), reveal a detailed picture of how specific conformation affects fluorescence. Fluorescence emission spectra and time-resolved emission measurements have been collected for all four charged species. MD simulations 20 to 30 ns in length have also been carried out for the Trp-Glu species, as simulation provides aqueous phase conformational data that can be correlated with the fluorescence data. The calculations show that each dipeptide species is characterized by a similar set of six, discrete Chi 1, Chi 2 dihedral angle pairs. The preferred Chi 1 angles--60°, 180°, and 300°--play the significant role in positioning the terminal amine relative to the indole ring. A Chi 1 angle of 60° results in the arching of the backbone over the indole ring and no interaction of the ring with the terminal amine. Chi 1 values of 180° and 300° result in an extension of the backbone away from the indole ring and a NH3 cation-π interaction with indole. This interaction is believed responsible for charge transfer quenching. Two fluorescence lifetimes and their corresponding amplitudes correlate with the Chi 1 angle probability distribution for all four charged Trp-Glu dipeptides. Fluorescence emission band maxima are also consistent with the proposed pattern of terminal amine cation quenching of fluorescence. Copyright © 2013 Wiley Periodicals, Inc.

  16. Design, synthesis and biological evaluation of novel ring-opened cromakalim analogues with relaxant effects on vascular and respiratory smooth muscles and as stimulators of elastin synthesis.

    Science.gov (United States)

    Bouhedja, Mourad; Peres, Basile; Fhayli, Wassim; Ghandour, Zeinab; Boumendjel, Ahcène; Faury, Gilles; Khelili, Smail

    2018-01-20

    Two new series of ring-opened analogues of cromakalim bearing sulfonylurea moieties (series A: with N-unmethylated sulfonylureas, series B: with N-methylated sulfonylureas) were synthesized and tested as relaxants of vascular and respiratory smooth muscles (rat aorta and trachea, respectively). Ex vivo biological evaluations indicated that the most active compounds, belonging to series B, displayed a marked vasorelaxant activity on endothelium-intact aortic rings and the trachea. A majority of series B compounds exhibited a higher vasorelaxant activity (EC 50  stronger relaxant effects on the trachea than the reference compound cromakalim (EC 50  = 124 μM), in particular compounds B4, B7 and B16 (EC 50   57 μM for all, and EC 50  > 200 μM for a majority of them), but some of them showed an interesting relaxing effect on trachea (i.e. A15 and A33, EC 50  = 30 μM). The most potent compounds of both series, i.e. A15, A33 and B16, tested on aortic rings in the presence of glibenclamide or 80 mM KCl, suggested that they acted as voltage-gated Ca 2+ channel blockers, like verapamil, instead of being ATP-potassium channel activators, as is cromakalim, the parent molecule. Further investigations on cultured vascular smooth muscle cells showed a strong stimulating effect on elastin synthesis, especially compound B16, which was more active at 20 μM than diazoxide, a reference ATP-sensitive potassium channel activator. Taken together, our results show that the N-methylation of the sulfonylurea moieties of ring-opened cromakalim analogues led to new compounds blocking calcium-gated channels, which had a major impact on the arterial and tracheal activities as well as selectivity. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  17. Presentation of Primary Open Angle Glaucoma (POAG) at Lions ...

    African Journals Online (AJOL)

    eye hospital in Malawi and serves as the main teaching eye hospital for the ... anterior chamber angle by a Goldmann three-mirror contact lens. IOPs of all the .... Traditional healers play a role in the health care of patients with eye problems.

  18. Zn(OAc2-Catalyzing Ring-Opening Polymerization of N-Carboxyanhydrides for the Synthesis of Well-Defined Polypeptides

    Directory of Open Access Journals (Sweden)

    Yanzhao Nie

    2018-03-01

    Full Text Available Despite notable progress, the fabrication of well-defined polypeptides via controlled ring-opening polymerization (ROP of α-amino acid N-carboxyanhydrides (NCAs using convenient catalysts under mild conditions in a relatively short polymerization time is still challenging. Herein, an easily obtained catalyst system composed of zinc acetate and aniline was explored to mediate the fast ROP of γ-benzyl-l-glutamate-N-carboxyanhydride (BLG-NCA monomer, to produce poly(γ-benzyl-l-glutamates (PBLGs with controllable molecular weights and narrow dispersity. Considering the excellent cooperative action of zinc acetate and a broad scope of aniline derivatives with different functional groups to control ROP of BLG-NCA, this method may offer a useful platform enabling the rapid generation of end-functionalized PBLG and block copolymers for numerous biomedical applications.

  19. Initial Reactivity of Linkages and Monomer Rings in Lignin Pyrolysis Revealed by ReaxFF Molecular Dynamics.

    Science.gov (United States)

    Zhang, Tingting; Li, Xiaoxia; Guo, Li

    2017-10-24

    The initial conversion pathways of linkages and their linked monomer units in lignin pyrolysis were investigated comprehensively by ReaxFF MD simulations facilitated by the unique VARxMD for reaction analysis. The simulated molecular model contains 15 920 atoms and was constructed on the basis of Adler's softwood lignin model. The simulations uncover the initial conversion ratio of various linkages and their linked aryl monomers. For linkages and their linked monomer aryl rings of α-O-4, β-O-4 and α-O-4 & β-5, the C α /C β ether bond cracking dominates the initial pathway accounting for at least up to 80% of their consumption. For the linkage of β-β & γ-O-α, both the C α -O ether bond cracking and its linked monomer aryl ring opening are equally important. Ring-opening reactions dominate the initial consumption of other 4-O-5, 5-5, β-1, β-2, and β-5 linkages and their linked monomers. The ether bond cracking of C α -O and C β -O occurs at low temperature, and the aryl ring-opening reactions take place at relatively high temperature. The important intermediates leading to the stable aryl ring opening are the phenoxy radicals, the bridged five-membered and three-membered rings and the bridged six-membered and three-membered rings. In addition, the reactivity of a linkage and its monomer aryl ring may be affected by other linkages. The ether bond cracking of α-O-4 and β-O-4 linkages can activate its neighboring linkage or monomer ring through the formed phenoxy radicals as intermediates. The important intermediates revealed in this article should be of help in deepening the understanding of the controlling mechanism for producing aromatic chemicals from lignin pyrolysis.

  20. Beam-beam force and storage ring parameters

    International Nuclear Information System (INIS)

    Herrera, J.C.

    1979-01-01

    The fundamental aspects of the beam--beam force as it occurs in Intersecting Storage Rings are reported. The way in which the effect of the beam--particle electromagnetic force (weak--strong interaction) is different in the case of unbunched proton beams which cross each other at an angle (as in the ISR and in ISABELLE) is shown, as compared to the case of electron--positron beams where bunches collide head-on

  1. Development of stress analyzer using whole back reflection ring

    International Nuclear Information System (INIS)

    Shitaba, Yuichi; Ishikawa, Tetsuro; Ohya, Shin-ichi; Akita, Koichi

    2006-01-01

    The X-ray stress measurement based on sin 2 ψ method has been widely adopted. This technique is not entirely efficient, because it is necessary to measure each diffraction profile one after other at five and more incident X-ray angles. On the other hand, stress measurement based on cosα method was proposed using X-ray film as detector. In this method, the stresses are determined from Debye-ring obtained at a single X-ray incident angle with high efficiency. However, it has the problem in this accuracy on stress determination. In this study, a new stress analyzer with sixteen position sensitive proportional counters (PSPC) radially arranged for incidence X-ray was developed. We examined to determine the plane stress components by multi-regression analysis using sixteen diffraction angles on a Debye-ring. As a result, stress components of σ x and τ xy were measured with sufficient accuracy. However, a stress of σ y had large dispersion, because of low strain sensitivity in the y direction. Moreover, it was clarified that σ y had pseud-multicollinearity on multi-regression analysis. The accuracy of σ y value itself could not be improved, though an analysis to eliminate an effect of pseud-multicollinearity was carried out. In this paper, we proposed the new method to determine the components using two Debye rings obtained by X-ray incidences in both x and y directions. We tried to measure the residual stress components in the butt welded joint using the method. As a result, it was confirmed that the stresses, σ x and σ y , were obtained in the sufficient accuracy, and that the shear stress, τ xy , was arising near the bond in the welds. (author)

  2. Fixed combination of bimatoprost and timolol in patients with primary open-angle glaucoma or ocular hypertension with inadequate IOP adjustment

    Directory of Open Access Journals (Sweden)

    Gerrett Brief

    2010-09-01

    Full Text Available Gerrett Brief1, Tobias Lammich2, Edgar Nagel3, Sabine Pfennigsdorf4, Christoph W Spraul5, Selwyn Ho61Facharzt für Augenheilkunde, Dortmund, Germany; 2Neubrandenburg, Germany; 3Augenarztpraxis Rudolstadt, Germany; 4Polch, Germany; 5Geiselhart, Ulm, Germany; 6Allergan Europe, Marlow, UKObjective: To assess the efficacy and tolerability of a fixed combination of bimatoprost and timolol (BTFC in a large patient sample in a clinical setting.Methods: In this multicenter, observational, noncontrolled, open-label study, patients (n = 1862 with primary open-angle glaucoma or ocular hypertension were treated with BTFC. Assessments were made at baseline, six weeks, and three months.Results: Prior to starting BTFC, 92.3% of patients were taking other ocular hypotensive medications. In the overall group at three months, mean intraocular pressure was reduced from baseline (21.7 ± 4.5 mmHg and 21.8 ± 4.9 mmHg for the right and left eye, respectively to 16.1 ± 3.0 mmHg for each eye (P < 0.0001. The majority of patients (92% reported no adverse events. The most commonly reported adverse events (in >1% of patients were eye irritation, and ocular and conjunctival hyperemia. Adherence to treatment was generally better than (35.4% or the same as (57.5% with prior therapy. BTFC tolerability was rated as excellent or good by 92.3% of physicians and 85.8% of patients.Conclusions: In a large group of patients with primary open-angle glaucoma or ocular hypertension, treatment with BTFC was associated with consistent reductions in IOP, improved adherence to treatment, and good tolerability.Keywords: bimatoprost, timolol, intraocular pressure, fixed combination, glaucoma

  3. Clinical and epidemiological study in patients with primary open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    Luciana dos Mares Guia Ribeiro

    Full Text Available Abstract Objective: To evaluate the clinical and epidemiological profile of patients with primary open-angle glaucoma. Methods: This is a quantitative study with cross-sectional and analytical design, which sample consisted of 425 patients treated in an unit of Specialized Care in Ophthalmology, located in the northern state of Minas Gerais, from 2004 to 2015. We collected the data using formularies that addressed demographic and clinical aspects, risk factors and the presence of undercurrent diseases. We conducted an ophthalmological examination to evaluate anatomical and functional changes. We used statistical analysis, and the results are presented by mean, standard deviation and percentiles 25, 50 and 75. Results: Females predominate (56.8%, the age group of 60 years or older (44% and mixed skin (81.7%. A minority of participants present risk factors such as high myopia (6.3% and diabetes mellitus (17.9%. Regarding the clinical examination, there is a prevalence of increased optic nerve excavation (≥ 0.8 and low thickness of the corneas (≤ 535 microns. Conclusion: Most people develop advanced glaucoma, with increased optic nerve excavation and changed visual fields. Other common risk factors are: family history of glaucoma, decreased thickness of the cornea and hypertension. Early diagnosis and treatment can prevent vision loss. Primary care physicians should consider referring patients who have glaucoma risk factors, for an ophthalmologic examination.

  4. Common genetic determinants of intraocular pressure and primary open-angle glaucoma.

    Directory of Open Access Journals (Sweden)

    Leonieke M E van Koolwijk

    Full Text Available Intraocular pressure (IOP is a highly heritable risk factor for primary open-angle glaucoma and is the only target for current glaucoma therapy. The genetic factors which determine IOP are largely unknown. We performed a genome-wide association study for IOP in 11,972 participants from 4 independent population-based studies in The Netherlands. We replicated our findings in 7,482 participants from 4 additional cohorts from the UK, Australia, Canada, and the Wellcome Trust Case-Control Consortium 2/Blue Mountains Eye Study. IOP was significantly associated with rs11656696, located in GAS7 at 17p13.1 (p=1.4×10(-8, and with rs7555523, located in TMCO1 at 1q24.1 (p=1.6×10(-8. In a meta-analysis of 4 case-control studies (total N = 1,432 glaucoma cases, both variants also showed evidence for association with glaucoma (p=2.4×10(-2 for rs11656696 and p=9.1×10(-4 for rs7555523. GAS7 and TMCO1 are highly expressed in the ciliary body and trabecular meshwork as well as in the lamina cribrosa, optic nerve, and retina. Both genes functionally interact with known glaucoma disease genes. These data suggest that we have identified two clinically relevant genes involved in IOP regulation.

  5. Elevated urine formaldehyde in elderly patients with primary open angle glaucoma

    Directory of Open Access Journals (Sweden)

    Ying Cui

    2016-03-01

    Full Text Available AIM: To investigate the risk factor of primary open angle glaucoma (POAG, which is the leading cause of irreversible blindness worldwide. An abnormally high level of endogenous formaldehyde (FA has recently been found correlated with cell death and neurodegenerative disease, raising the possibility of a putative correlation of abnormal endogenous FA with POAG. METHODS: Thirty-four elderly patients with POAG and sixteen healthy controls were enrolled. Glaucomatous visual defects were present at both the functional (visual field and structural [retinal nerve fiber layer (RNFL thickness] levels. Morning urine samples were obtained and were analyzed by high-performance liquid chromatography (HPLC to detect the endogenous FA level in a double blind manner. RESULTS: Patients with POAG (P<0.05 had significantly higher urine FA levels. The urine FA level of patients with severe visual field defects [mean deviation (MD≥12 dB] was significantly (P<0.001 greater than that of patients with mild to moderate defects (MD<12 dB. By optical coherence tomography (OCT, the superior and inferior RNFL thickness of POAG group was significantly (P<0.001 thinner than in controls. Furthermore, the superior and inferior thinning of the RNFL was correlated with the elevation of urine FA concentration. CONCLUSION: Endogenous FA level is positively correlated with the neuronal defects of POAG.

  6. Open-angle glaucoma in Filipino and white Americans: a comparative study.

    Science.gov (United States)

    Sáles, Christopher S; Lee, Roland Y; Agadzi, Anthony K; Hee, Michael R; Singh, Kuldev; Lin, Shan C

    2014-01-01

    To compare the frequency of open-angle glaucoma (OAG) subtypes between Filipino and white Americans in a general ophthalmology clinic population. In this retrospective cross-sectional epidemiologic study with prospective sampling, medical charts of 1113 patients aged 40 years or older (513 Filipinos, 600 whites) seen in 2008 were randomly sampled from 2 private comprehensive ophthalmology clinics. Glaucoma was diagnosed based on optic nerve appearance, visual field defects, and other ocular findings using the International Society of Geographical and Epidemiological Ophthalmology (ISGEO) scheme. The normal-tension subtype of OAG [normal-tension glaucoma (NTG)] was defined by intraocular pressure ≤21 mm Hg as determined by review of medical records. NTG comprised a greater proportion of all glaucomatous disease in Filipino subjects [Filipino (F) vs. white (W): 46.7% vs. 26.8%; P=0.02]. Filipinos were more commonly diagnosed with OAG and NTG than whites (F vs. W: OAG, 11.9% vs. 8.2%; NTG, 6.8% vs. 2.5%; P=0.04, 0.001, respectively). There was no significant difference in central corneal thickness between Filipino and white subjects with NTG (P=0.66). Both OAG and NTG may be more common in Filipino Americans than in white Americans with the propensity for NTG being particularly high in the former relative to the latter group.

  7. Cytokine biomarkers in tear film for primary open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    Gupta D

    2017-02-01

    Full Text Available Divakar Gupta,1,* Joanne C Wen,2,* Janet L Huebner,3 Sandra Stinnett,1 Virginia B Kraus,3,4 Henry C Tseng,1 Molly Walsh1 1Department of Ophthalmology, Duke University Medical Center, Durham, NC, 2Department of Ophthalmology, University of Washington, Seattle, WA, 3Duke Molecular Physiology Institute, 4Division of Rheumatology, Department of Medicine, Duke University School of Medicine, Durham, NC, USA *These authors contributed equally to this work Purpose: To determine the utility of tear film cytokines as biomarkers for early primary open-angle glaucoma (POAG. Methods: Patients without POAG and eye drop-naïve patients with newly diagnosed POAG were recruited from an academic hospital-based glaucoma practice. Tear films of recruited patients were obtained and analyzed using a multiplex, high-sensitivity electrochemiluminescent enzyme-linked immunosorbent assay for proinflammatory cytokines (IFNγ, IL-10, IL-12p70, IL-13, IL-1β, IL-2, IL-4, IL-6, IL-8, and TNFα. Results: Mean concentrations of tear film cytokines were lower in the glaucoma group for 8 of 10 cytokines tested. IL-12p70 (3.94±2.19 pg/mL in control vs 2.31±1.156 pg/mL in POAG; P=0.035 was significantly lower in the tear film of patients with newly diagnosed POAG. Conclusion: Proinflammatory cytokines were lower in eye drop-naïve newly diagnosed glaucoma patients. Tear film cytokine profiles may be used as biomarkers of early POAG. Keywords: glaucoma, biomarkers, tear film, cytokines, glaucoma diagnosis, lower limit of detection

  8. Distinct iris gene expression profiles of primary angle closure glaucoma and primary open angle glaucoma and their interaction with ocular biometric parameters.

    Science.gov (United States)

    Seet, Li-Fong; Narayanaswamy, Arun; Finger, Sharon N; Htoon, Hla M; Nongpiur, Monisha E; Toh, Li Zhen; Ho, Henrietta; Perera, Shamira A; Wong, Tina T

    2016-11-01

    This study aimed to evaluate differences in iris gene expression profiles between primary angle closure glaucoma (PACG) and primary open angle glaucoma (POAG) and their interaction with biometric characteristics. Prospective study. Thirty-five subjects with PACG and thirty-three subjects with POAG who required trabeculectomy were enrolled at the Singapore National Eye Centre, Singapore. Iris specimens, obtained by iridectomy, were analysed by real-time polymerase chain reaction for expression of type I collagen, vascular endothelial growth factor (VEGF)-A, -B and -C, as well as VEGF receptors (VEGFRs) 1 and 2. Anterior segment optical coherence tomography (ASOCT) imaging for biometric parameters, including anterior chamber depth (ACD), anterior chamber volume (ACV) and lens vault (LV), was also performed pre-operatively. Relative mRNA levels between PACG and POAG irises, biometric measurements, discriminant analyses using genes and biometric parameters. COL1A1, VEGFB, VEGFC and VEGFR2 mRNA expression was higher in PACG compared to POAG irises. LV, ACD and ACV were significantly different between the two subgroups. Discriminant analyses based on gene expression, biometric parameters or a combination of both gene expression and biometrics (LV and ACV), correctly classified 94.1%, 85.3% and 94.1% of the original PACG and POAG cases, respectively. The discriminant function combining genes and biometrics demonstrated the highest accuracy in cross-validated classification of the two glaucoma subtypes. Distinct iris gene expression supports the pathophysiological differences that exist between PACG and POAG. Biometric parameters can combine with iris gene expression to more accurately define PACG from POAG. © 2016 The Authors. Clinical & Experimental Ophthalmology published by John Wiley & Sons Australia, Ltd on behalf of Royal Australian and New Zealand College of Ophthalmologists.

  9. Laser peripheral iridoplasty for angle-closure.

    Science.gov (United States)

    Ng, Wai Siene; Ang, Ghee Soon; Azuara-Blanco, Augusto

    2012-02-15

    Angle-closure glaucoma is a leading cause of irreversible blindness in the world. Treatment is aimed at opening the anterior chamber angle and lowering the IOP with medical and/or surgical treatment (e.g. trabeculectomy, lens extraction). Laser iridotomy works by eliminating pupillary block and widens the anterior chamber angle in the majority of patients. When laser iridotomy fails to open the anterior chamber angle, laser iridoplasty may be recommended as one of the options in current standard treatment for angle-closure. Laser peripheral iridoplasty works by shrinking and pulling the peripheral iris tissue away from the trabecular meshwork. Laser peripheral iridoplasty can be used for crisis of acute angle-closure and also in non-acute situations.   To assess the effectiveness of laser peripheral iridoplasty in the treatment of narrow angles (i.e. primary angle-closure suspect), primary angle-closure (PAC) or primary angle-closure glaucoma (PACG) in non-acute situations when compared with any other intervention. In this review, angle-closure will refer to patients with narrow angles (PACs), PAC and PACG. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2011, Issue 12), MEDLINE (January 1950 to January 2012), EMBASE (January 1980 to January 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2012), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). There were no date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 5 January 2012. We included only randomised controlled trials (RCTs) in this review. Patients with narrow angles, PAC or PACG were eligible. We excluded studies that included only patients with acute presentations

  10. Control of the rings of exceptional points in photonic crystal slabs

    DEFF Research Database (Denmark)

    Kaminski, Piotr Marek; Breinbjerg, Olav; Mørk, Jesper

    2017-01-01

    shown that when the system becomes non-Hermitian, e.g. it is an open system exhibiting radiation losses, Dirac cones can be deformed spawning rings of exceptional points [2]. Within the ring, the dispersion follows the two-dimensional flat band which provides a high density of states and therefore high...

  11. The Cerenkov ring-imaging detector recent progress and future development

    CERN Document Server

    Ekelöf, T J C; Tocqueville, J; Ypsilantis, Thomas

    1981-01-01

    Results are reported on measurements of Cerenkov ring images using a multistage MWPC with an argon-TEA gas mixture. A specific detector response of N/sub 0/=56 cm/sup -1/ was obtained. It is shown that with some minor modifications to the detector, this value can be raised to N/sub 0/=90 cm/sup -1/. Using an argon-methane-TEA mixture in the MWPC, it is shown that efficient single-photoelectron detection can be achieved with proportional wire amplification without preamplification. A design of a new type of drift chamber (TPC) detector for two-dimensional measurement of the ring image is described. The use of the Cerenkov ring-imaging technique in high- energy physics experimentation is discussed, and in particular a full solid-angle detector for LEP is suggested. (10 refs).

  12. Application of combinatorial biocatalysis for a unique ring expansion of dihydroxymethylzearalenone.

    Science.gov (United States)

    Rich, Joseph O; Budde, Cheryl L; McConeghey, Luke D; Cotterill, Ian C; Mozhaev, Vadim V; Singh, Sheo B; Goetz, Michael A; Zhao, Annie; Michels, Peter C; Khmelnitsky, Yuri L

    2009-06-01

    Combinatorial biocatalysis was applied to generate a diverse set of dihydroxymethylzearalenone analogs with modified ring structure. In one representative chemoenzymatic reaction sequence, dihydroxymethylzearalenone was first subjected to a unique enzyme-catalyzed oxidative ring opening reaction that creates two new carboxylic groups on the molecule. These groups served as reaction sites for further derivatization involving biocatalytic ring closure reactions with structurally diverse bifunctional reagents, including different diols and diamines. As a result, a library of cyclic bislactones and bislactams was created, with modified ring structures covering chemical space and structure activity relationships unattainable by conventional synthetic means.

  13. Type II GaSb quantum ring solar cells under concentrated sunlight.

    Science.gov (United States)

    Tsai, Che-Pin; Hsu, Shun-Chieh; Lin, Shih-Yen; Chang, Ching-Wen; Tu, Li-Wei; Chen, Kun-Cheng; Lay, Tsong-Sheng; Lin, Chien-Chung

    2014-03-10

    A type II GaSb quantum ring solar cell is fabricated and measured under the concentrated sunlight. The external quantum efficiency confirms the extended absorption from the quantum rings at long wavelength coinciding with the photoluminescence results. The short-circuit current of the quantum ring devices is 5.1% to 9.9% more than the GaAs reference's under various concentrations. While the quantum ring solar cell does not exceed its GaAs counterpart in efficiency under one-sun, the recovery of the open-circuit voltages at higher concentration helps to reverse the situation. A slightly higher efficiency (10.31% vs. 10.29%) is reported for the quantum ring device against the GaAs one.

  14. The Jovian rings as observed from Jupiter.

    Science.gov (United States)

    Malinnikova Bang, A.; Joergensen, J. L.; Joergensen, P. S.; Denver, T.; Connerney, J. E. P.; Bolton, S. J.; Levin, S.

    2017-12-01

    Juno entered a highly eliptic orbit around Jupiter on the 4. July 2016. Since then, it has completed 8 perijove passages. The Magnetometer experiment consists of two measurement platforms mounted 10m and 12m from the spacecraft spin axis, on one of three large solar panels. Each magnetometer platform is equipped with two star trackers to provide accurate attitude information to the vector magnetometers. The star trackers are pointed 13deg from the (anti) spin vector, and clocked 180deg to avoid simultaneous blinding effects from bright Jupiter only 6000km away, during perijove. This brings Juno well inside the innermost known satellite, Metis. The star trackers pointing close to, and above the Jovian horizon for most of each rotation of Juno, has an excellent view of the Jovian ring systems with a beta-angle close to 180deg. We report on the ring imaging performed during the first 8 orbits, discuss the structure, optical depth and moon sheparding of the inner rings as measured so far.

  15. Electron ring design for HERA, including spin-matching

    International Nuclear Information System (INIS)

    Skuja, A.; Hand, L.; Steffen, K.; Barber, D.

    1984-01-01

    A. Skuja has been working in collaboration with Professor Lou Hand in obtaining an optics for the electron ring at HERA that satisfies the usual constraints of an electron storage ring, but in addition allows longitudinal polarization in the interaction region without depolarizing the electron beam completely. This collaboration effort grew out of their work on a possible electron ring at Fermilab. When this project was degraded in priority at Fermilab, they turned their attention to the HERA project at DESY. The HERA project will have an electron ring of about 30 GeV e - (or e + ) incident on 800 GeV protons. Recently it has been decided that the collisions should be head on (0 0 crossing), although all previous designs had a crossing angle of the 2 beams of 20 mrad. Professors Hand and Skuja implemented a complete program in the last year and a half that could fit the usual Turis parameters as well as the so called 12 spin-matching conditions of Chao and Yukoya for all possible machine elements including solenoids. The program has the possibility of fully coupling vertical and horizontal motion using the usual eigenvalue method

  16. Phosphazene-catalyzed ring-opening polymerization of ε-caprolactone: Influence of solvents and initiators

    KAUST Repository

    Alamri, Haleema; Zhao, Junpeng; Pahovnik, David; Hadjichristidis, Nikolaos

    2014-01-01

    Phosphazene base (t-BuP2) catalysed metal-free ring-opening polymerization of ε-caprolactone (ε-CL) at room temperature with various protic initiators in different solvents was investigated. The polymerization proceeded, in most cases, in a controlled manner to afford poly(ε-caprolactone) with low dispersities and expected molecular weights. Kinetic studies showed that when a primary alcohol was used as an initiator the polymerization rate in different solvents followed the order of dichloromethane ≫ toluene > 1,4-dioxane ≈ tetrahydrofuran. Extremely fast polymerization of l-lactide (LLA), which was added as a second monomer, was observed in different solvents giving rise to poly(ε-caprolactone)-b- poly(l-lactide) diblock copolymers with neat PLLA blocks despite incomplete conversion of ε-CL. The dependence of polymerization rate on the concentrations of ε-CL and t-BuP2 was also revealed. In addition to primary alcohol, the feasibility of using other protic initiators, such as secondary alcohol (either on a small molecule or a polymer chain-end), (aliphatic/aromatic) amide, carboxylic acid, phenol and thiophenol, was also investigated. These studies provided important information for designing a metal-free route towards polyester-based (bio)materials. © 2014 the Partner Organisations.

  17. Torsion angle dependence of the rectifying performance in molecular device with asymmetrical anchoring groups

    International Nuclear Information System (INIS)

    Wang, L.H.; Guo, Y.; Tian, C.F.; Song, X.P.; Ding, B.J.

    2010-01-01

    Using first-principles density functional theory and nonequilibrium Green's function formalism, we investigate the effect of torsion angle on the rectifying characteristics of 4'-thiolate-biphenyl-4-dithiocarboxylate sandwiched between two Au(111) electrodes. The results show that the torsion angle has an evident influence on rectifying performance of such devices. By increasing the dihedral angle between two phenyl rings, namely changing the magnitude of the intermolecular coupling effect, a different rectifying behavior can be observed in these systems. Our findings highlight that the rectifying characteristics are intimately related to dihedral angles and can provide fundamental guidelines for the design of functional molecular devices.

  18. Crossing geometry for Main Ring on Doubler collisions

    International Nuclear Information System (INIS)

    Diebold, R.

    1977-01-01

    There are two basic methods for bringing about Main Ring on Doubler collisions: the transposed, and kissing geometries. Examples of both are discussed assuming maximum momenta of 250 on 1000 GeV/c. The magnets required to bring the beams into small-angle collision are substantial in both cases. Detailed engineering work will be required to distinguish a substantial cost advantage of one geometry over the other

  19. On the stability of pick-up ion ring distributions in the outer heliosheath

    International Nuclear Information System (INIS)

    Summerlin, Errol J.; Viñas, Adolfo F.; Moore, Thomas E.; Christian, Eric R.; Cooper, John F.

    2014-01-01

    The 'secondary energetic neutral atom (ENA)' hypothesis for the ribbon feature observed by the Interstellar Boundary Explorer (IBEX) posits that the neutral component of the solar wind continues beyond the heliopause and charge exchanges with interstellar ions in the Outer Heliosheath (OHS). This creates pick-up ions that gyrate about the draped interstellar magnetic field (ISMF) lines at pitch angles near 90° on the locus where the ISMF lies tangential to the heliopause and perpendicular to the heliocentric radial direction. This location closely coincides with the location of the ribbon feature according to the prevailing inferences of the ISMF orientation and draping. The locally gyrating ions undergo additional charge exchange and escape as free-flying neutral atoms, many of which travel back toward the inner solar system and are imaged by IBEX as a ribbon tracing out the locus described above. For this mechanism to succeed, the pick-up ions must diffuse in pitch angle slowly enough to permit secondary charge exchange before their pitch angle distribution substantially broadens away from 90°. Previous work using linear Vlasov dispersion analysis of parallel propagating waves has suggested that the ring distribution in the OHS is highly unstable, which, if true, would make the secondary ENA hypothesis incapable of rendering the observed ribbon. In this paper, we extend this earlier work to more realistic ring distribution functions. We find that, at the low densities necessary to produce the observed IBEX ribbon via the secondary ENA hypothesis, growth rates are highly sensitive to the temperature of the beam and that even very modest temperatures of the ring beam corresponding to beam widths of <1° are sufficient to damp the self-generated waves associated with the ring beam. Thus, at least from the perspective of linear Vlasov dispersion analysis of parallel propagating waves, there is no reason to expect that the ring distributions necessary to

  20. Revisiting the Fully Automated Double-Ring Infiltrometer Using Open-Source Electronics

    Science.gov (United States)

    The double-ring infiltrometer (DRI) is commonly used for measuring soil hydraulic conductivity. However, constant-head DRI tests typically involve the use of Mariotte tubes, which can be problematic to set-up, and time-consuming to maintain and monitor during infiltration tests....

  1. A Rectangular Ring, Open-Ended Monopole Antenna with Two Symmetric Strips for WLAN and WiMAX Applications

    Directory of Open Access Journals (Sweden)

    Joong-Han Yoon

    2013-01-01

    Full Text Available A triple-band rectangular ring, open-ended monopole antenna with symmetric L strips for wireless local area network (WLAN/Worldwide Interoperability of Microwave Access (WiMAX applications is proposed. The proposed antenna consists of two symmetric folded arms and L strips. Based on the concept, a prototype of the proposed triple antenna has been designed, fabricated, and tested. The numerical and experimental results demonstrated that the proposed antenna satisfied the −10 dB impedance bandwidth requirement while simultaneously covering the WLAN and WiMAX bands. Furthermore, this paper presented and discussed the 2D radiation patterns and 3D gains according to the results of the experiment. The proposed antenna’s peak gain varied between 2.17 and 4.93 dBi, and its average gain varied between −2.97 and −0.53 dBi.

  2. Analysis of reforming process of large distorted ring in final enlarging forging

    International Nuclear Information System (INIS)

    Miyazawa, Takeshi; Murai, Etsuo

    2002-01-01

    In the construction of reactors or pressure vessels for oil chemical plants and nuclear power stations, mono block open-die forging rings are often utilized. Generally, a large forged ring is manufactured by means of enlarging forging with reductions of the wall thickness. During the enlarging process the circular ring is often distorted and becomes an ellipse in shape. However the shape control of the ring is a complicated work. This phenomenon makes the matter still worse in forging of larger rings. In order to make precision forging of large rings, we have developed the forging method using a v-shape anvil. The v-shape anvil is geometrically adjusted to fit the distorted ring in the final circle and reform automatically the shape of the ring during enlarging forging. This paper has analyzed the reforming process of distorted ring by computer program based on F.E.M. and examined the effect on the precision of ring forging. (author)

  3. Lit and unlit side temperatures of the Main Rings of Saturn.

    Science.gov (United States)

    Flandes, A.; Garcia, A.; Deau, E.; Spilker, L. J.

    2017-12-01

    The differences in the temperatures of both the lit and unlit sides of the main rings of Saturn can reveal important information about their structure. In general, the temperature of the main rings strongly depends upon the distribution and the general structure of the ensembles of particles that compose them, mainly due to shadowing effects that modulate how much energy reaches the individual particles -granted that the direct solar energy is the main driver of the rings' temperature-. In order to reproduce the temperatures of both sides of the rings, we use a semi-analytical energy balance model (considering solar direct and Saturn reflected energy, Saturn thermal energy and particles' thermal energies), where the shadowed fractional areas of the rings are removed through a shadowing function. We obtain this function (dependent on the solar elevation angle) for 13 different regions (for the A, CD, B and C rings) along the radial direction that are simulated using arrays of lambertian spherical particles based on the average properties of the structure of these regions derived from the Cassini UVIS observations. The obtained synthetic temperatures are compared to the Cassini CIRS measured temperatures (from -22º to equinox) with good agreement.

  4. Azirinium ylides from α-diazoketones and 2H-azirines on the route to 2H-1,4-oxazines: three-membered ring opening vs 1,5-cyclization

    Directory of Open Access Journals (Sweden)

    Nikolai V. Rostovskii

    2015-03-01

    Full Text Available Strained azirinium ylides derived from 2H-azirines and α-diazoketones under Rh(II-catalysis can undergo either irreversible ring opening across the N–C2 bond to 2-azabuta-1,3-dienes that further cyclize to 2H-1,4-oxazines or reversibly undergo a 1,5-cyclization to dihydroazireno[2,1-b]oxazoles. Dihydroazireno[2,1-b]oxazoles derived from 3-aryl-2H-azirines and 3-diazoacetylacetone or ethyl diazoacetoacetate are able to cycloadd to acetyl(methylketene generated from 3-diazoacetylacetone under Rh(II catalysis to give 4,6-dioxa-1-azabicyclo[3.2.1]oct-2-ene and/or 5,7-dioxa-1-azabicyclo[4.3.1]deca-3,8-diene-2-one derivatives. According to DFT calculations (B3LYP/6-31+G(d,p, the cycloaddition can involve two modes of nucleophilic attack of the dihydroazireno[2,1-b]oxazole intermediate on acetyl(methylketene followed by aziridine ring opening into atropoisomeric oxazolium betaines and cyclization. Azirinium ylides generated from 2,3-di- and 2,2,3-triaryl-substituted azirines give rise to only 2-azabuta-1,3-dienes and/or 2H-1,4-oxazines.

  5. Thermoset polymers via ring opening metathesis polymerization of functionalized oils

    Science.gov (United States)

    Larock, Richard C; Henna, Phillip H; Kessier, Michael R

    2012-11-27

    The invention provides a method for producing a thermosetting resin from renewable oils, the method comprising supplying renewable oil molecules containing strained ring alkene moieties; reacting the alkene moieties with cyclic alkenes to create a polymer; and repeating the above two steps until the resin having desired characteristics are obtained. Also provided is a thermoset resin comprising functionalized renewable oil polymerized with a co-monomer.

  6. The ring plus project: safety and acceptability of vaginal rings that protect women from unintended pregnancy.

    Science.gov (United States)

    Schurmans, Céline; De Baetselier, Irith; Kestelyn, Evelyne; Jespers, Vicky; Delvaux, Thérèse; Agaba, Stephen K; van Loen, Harry; Menten, Joris; van de Wijgert, Janneke; Crucitti, Tania

    2015-04-10

    Research is ongoing to develop multipurpose vaginal rings to be used continuously for contraception and to prevent Human Immunodeficiency Virus (HIV) infection. Contraceptive vaginal rings (CVRs) are available in a number of countries and are most of the time used intermittently i.e. three weeks out of a 4-week cycle. Efficacy trials with a dapivirine-containing vaginal ring for HIV prevention are ongoing and plans to develop multi-purpose vaginal rings for prevention of both HIV and pregnancy have been elaborated. In contrast with the CVRs, multi-purpose vaginal rings will have to be used continuously. Women who continuously use a CVR will no longer have menses. Furthermore, some safety aspects of CVR use have never been studied in-depth in the past, such as the impact of the vaginal ring on the vaginal microbiota, biofilm formation and induction of inflammation. We studied acceptability and these novel aspects of safety in Rwandan women. Although significant progress has been made over the past decade, Rwanda still has a high unmet need for contraception (with 47% unplanned births) and a generalized HIV epidemic, and CVRs are not yet available. We will conduct an open label, single centre, randomized controlled trial. A total of 120 HIV-negative women will be randomized to intermittent CVR use (to allow menstruation) or continuous CVR use. Women will be followed for a maximum of 14 weeks. In parallel, we will conduct a qualitative study using in-depth interview and focus group discussion methodology. In addition to evaluating the safety and acceptability of intermittent and continuous CVR use in Rwandan women, we hope that our findings will inform the development of future multipurpose vaginal rings, will prepare Rwandan study populations for future clinical trials of multipurpose vaginal rings, and will pave the way for introduction of CVRs on African markets. Clinicaltrials.gov NCT01796613 . Registered 14 February 2013.

  7. Minimal open strings

    International Nuclear Information System (INIS)

    Hosomichi, Kazuo

    2008-01-01

    We study FZZT-branes and open string amplitudes in (p, q) minimal string theory. We focus on the simplest boundary changing operators in two-matrix models, and identify the corresponding operators in worldsheet theory through the comparison of amplitudes. Along the way, we find a novel linear relation among FZZT boundary states in minimal string theory. We also show that the boundary ground ring is realized on physical open string operators in a very simple manner, and discuss its use for perturbative computation of higher open string amplitudes.

  8. Factors associated with lifetime risk of open-angle glaucoma blindness.

    Science.gov (United States)

    Peters, Dorothea; Bengtsson, Boel; Heijl, Anders

    2014-08-01

    To investigate factors associated with bilateral glaucoma blindness, particularly factors available at the time of diagnosis. Retrospective chart review of all patients with primary open-angle glaucoma (POAG) or pseudoexfoliative glaucoma (PEXG) followed at the Department of Ophthalmology or Low Vision Center of Skåne University Hospital, Malmö, Sweden, who died between January 2006 and June 2010. Disease stage at diagnosis was defined by a simplified version of Mills' glaucoma staging system using perimetric mean deviation (MD) to define six stages of severity. Blindness was defined according to WHO criteria. We used logistic regression analysis to examine the association between risk factors and glaucoma blindness. Four hundred and 23 patients were included; 60% POAG and 40% PEXG. Sixty-four patients (15%) became blind from glaucoma. Blind patients had significantly longer mean duration with diagnosed disease than patients who did not go blind (14.8 years ± 5.8 versus 10.6 years ± 6.5, p blindness increased with higher intraocular pressure (IOP) (OR 1.08, 95% CI 1.03-1.13) and with each stage of more advanced field loss at time of diagnosis (OR 1.80 95% CI 1.34-2.41). Older age at death was also associated with an increased risk of blindness (OR 1.09 95% CI 1.03-1.14), while age at diagnosis was unimportant. PEXG was not an independent risk factor for blindness. Higher IOP and worse visual field status at baseline were important risk factors, as was older age at death. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  9. Active interlock system for high power insertion devices in the x-ray ring

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    In modern synchrotron radiation rings photon beams generated by high power insertion devices (IDs) may be sufficiently intense to cause severe thermal damage to the machine vacuum chamber if mis-steered. Thus when operating a storage ring with the IDs, great care must be exercised to prevent mis-steering of the electron beam orbit. At present, the X-ray ring operates with three IDs, namely two hybrid wigglers (HBW) at X-21 and X-25,a nd a 5-Tesla superconducting wiggler at X-17. All wigglers are located in low-beta straight sections. In the straight sections. In the straight sections, beam orbit may be deflected by as much as ±8 mrad without scraping the chamber wall. For various reasons it was not possible to design the X-ray ring vacuum chamber to be safe under all possible operating conditions, however, the chamber is safe for i < 7 mA, all horizontal beam deflection angles and for vertical angles < ± 2.5 mrad. To protect the machine vacuum chamber from damage due to mis-steered beams, and interlock system has been developed and installed. This system utilizes active beam position detectors which continuously monitor beam motion in each of the ID straight sections and logic circuitry which interrupts the RF and dumps the stored beam in the case of a fault

  10. Wideband Photometry of Saturn: 1995-2007

    Science.gov (United States)

    Schmude, Richard W.

    2007-10-01

    The writer has measured the brightness of Saturn + rings at four wavelengths (0.44 to 0.86 microns) every year since 1995 using a single channel photometer. Filters transformed to the Johnson B, V, R and I system were used in all measurements. The main conclusions of this 12 year study are: 1) The color of Saturn + rings does not change in visible light as the solar phase angle drops from 6 to 2 degrees. 2) The color of Saturn + rings becomes a few percent bluer in visible light as the solar phase angle drops below 1.0 degree due to the opposition surge. 3) In visible wavelengths, the color of Saturn + rings does not change as the ring tilt changes from 4 to 27 degrees. 4) The R-I color index value increases by about 0.1 magnitudes as the ring tilt angle rises from 4 to 27 degrees. The opening of the rings is probably the cause of this change. 5) The solar phase angle coefficient of Saturn + rings is 0.027 magnitude/degree for a ring tilt angle of 14 degrees and it rises by about 0.0005 magnitude/degree for each 1 degree increase in ring tilt angle and it drops by about the same amount for each 1 degree drop in ring tilt angle. The writer would like to thank Gordon College for providing financial support for attending this meeting.

  11. ANALISIS SUDUT PANDANG KAMERA (Studi kasus: Film Jelangkung dan Film The Ring 1

    Directory of Open Access Journals (Sweden)

    Listia Natadjaja

    2005-01-01

    Full Text Available Horror movie is one of the strengths of Indonesian film industry; however it is not so popular in the International market. Thus%2C an analysis is needed to determine what the strengths are of another horror movie that has achieved global recognition. This analysis trie s to examine film angles that could be one of the important factors in audio visual in creating horror movies. The Ring 1 is chosen as a comparison to Indonesian horror movie. The Ring 1 has the most world recognition%2C and it has been re-made by Korean and American horror movie makers. Jelangkung is chosen because it is the pioneer of horror movies in Indonesia and has inspired other movies in the same genre. Both films are analyzed from the camera angle aspect which gives the horror effect. Abstract in Bahasa Indonesia : Film horor merupakan salah satu kekuatan perfilman layar lebar di Indonesia.%2C akan tetapi film horor Indonesia kurang dapat menyebar di pasaran Internasional. Oleh karena itu%2C suatu analisis diperlukan untuk mengetahui apakah kekuatan-kekuatan yang dimiliki oleh film horor negara-negara lain yang banyak digemari masyarakat global terutama dari sudut pandang kamera yang merupakan salah satu faktor penting dalam menciptakan kesan horor pada suatu film. Film The Ring 1 dipilih sebagai pedoman perbandingan film horor Indonesia%2C karena film The Ring 1 adalah film horor yang sangat banyak diminati oleh masyarakat di seluruh dunia%2C bahkan telah diremake oleh Korea dan USA. Film Horor Indonesia yang dipilih adalah film Jelangkung yang pertama kali muncul pada film layar lebar dan menjadi cikal bakal munculnya banyak film layar lebar di Indonesia dengan genre yang sama. Analisa kedua film ini ditinjau dari sudut pandang kamera yang dapat menampilkan kesan horor. horror movie%2C camera angle%2C Indonesia%2C Japan.

  12. The plasmasheet H+ and O+ contribution on the storm time ring current

    Science.gov (United States)

    Mouikis, C.; Bingham, S.; Kistler, L. M.; Spence, H. E.; Gkioulidou, M.; Claudepierre, S. G.; Farrugia, C. J.

    2015-12-01

    The source population of the storm time ring current is the night side plasma sheet. We use Van Allen Probes and Cluster observations to determine the contribution of the convecting plasma sheet H+ and O+ particles in the storm time development of the ring current. Using the Volland-Stern model with a dipole magnetic field together with the identification of the observed energy cutoffs in the particle spectra, we specify the pressure contributed by H+ and O+ populations that are on open drift paths vs. the pressure contributed by the trapped populations, for different local times. We find that during the storm main phase most of the ring current pressure in the pre-midnight inner magnetosphere is contributed by particles on open drift paths that cause the development of a strong partial ring current that causes most of the main phase Dst drop. These particles can reach as deep as L~2 and their pressure compares to the local magnetic field pressure as deep as L~3. During the recovery phase, if these particles are not lost at the magnetopause, will become trapped and will contribute to the symmetric ring current.

  13. Are we ready for genetic testing for primary open-angle glaucoma?

    Science.gov (United States)

    Khawaja, Anthony P; Viswanathan, Ananth C

    2018-05-01

    Following a dramatic reduction in the cost of genotyping technology in recent years, there have been significant advances in the understanding of the genetic basis of glaucoma. Glaucoma patients represent around a quarter of all outpatient activity in the UK hospital eye service and are a huge burden for the National Health Service. A potential benefit of genetic testing is personalised glaucoma management, allowing direction of our limited healthcare resources to the glaucoma patients who most need it. Our review aims to summarise recent discoveries in the field of glaucoma genetics and to discuss their potential clinical utility. While genome-wide association studies have now identified over ten genes associated with primary open-angle glaucoma (POAG), individually, variants in these genes are not predictive of POAG in populations. There are data suggesting some of these POAG variants are associated with conversion from ocular hypertension to POAG and visual field progression among POAG patients. However, these studies have not been replicated yet and such genetic testing is not currently justified in clinical care. In contrast, genetic testing for inherited early-onset disease in relatives of POAG patients with a known genetic mutation is of clear benefit; this can support either regular review to commence early treatment when the disease develops, or discharge from ophthalmology services of relatives who do not carry the mutation. Genetic testing for POAG at a population level is not currently justified.

  14. Parametric study of the damage ring pattern in fused silica induced by multiple longitudinal modes laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Chambonneau, M., E-mail: maxime.chambonneau@hotmail.fr; Grua, P.; Rullier, J.-L.; Lamaignère, L. [CEA CESTA, 15 Avenue des Sablières, CS 60001, 33116 Le Barp Cedex (France); Natoli, J.-Y. [Aix Marseille Université, CNRS, Centrale Marseille, Institut Fresnel, UMR 7249, 13013 Marseille (France)

    2015-03-14

    With the use of multiple longitudinal modes nanosecond laser pulses at 1064 nm, laser damage sites at the exit surface of fused silica clearly and systematically exhibit ring patterns. It has been shown in our previous works that the apparent chronology of rings was closely related to the temporal shape of the laser pulses. This particular correspondence had suggested an explanation of the ring morphology formation based on the displacement of an ionization front in the surrounding air. To provide a former basis for this hypothesis and deeper understanding of ring pattern formation, additional experiments have been performed. First, the impact of fluence has been investigated, revealing that a wide variety of damage sites are produced within a very narrow fluence range; this fact involves the chronology of appearance of a surface plasma during the laser pulse. The sizes of the damage sites are proportional to the fluence of their expansion occurring between the beginning of the plasma and the end of the laser pulse. Second, specific experiments have been carried out at different angles of incidence, resulting in egg-shaped patterns rather than circular ones. This behavior can be explained by our previous hypothesis of creation of a plasma in air, its expansion being tightly conditioned by the illumination angle. This series of experiments, in which the angle of incidence is varied up to 80°, permits us to link quantitatively the working hypothesis of ionization front propagation with theoretical hydrodynamics modeling.

  15. High Prevalence of Narrow Angles among Chinese-American Glaucoma and Glaucoma Suspect Patients

    Science.gov (United States)

    Seider, Michael I; Pekmezci, Melike; Han, Ying; Sandhu, Simi; Kwok, Shiu Y; Lee, Roland Y; Lin, Shan C

    2009-01-01

    Purpose To evaluate the prevalence of gonioscopically narrow angles in a Chinese-American population with glaucoma or glaucoma suspicion. Patients and Methods Charts from all Chinese-American patients seen in a comprehensive ophthalmology clinic in the Chinatown district of San Francisco in 2002 were reviewed. One eye from each patient with glaucoma or glaucoma suspicion that met inclusion criteria was included (n=108). Data was collected for gender, age, race (self-declared), refraction (spherical equivalent), intraocular pressure (IOP), gonioscopy and vertical cup-to-disk ratio (CDR). Results Sixty percent (n=65) of Chinese-American eyes with glaucoma or glaucoma suspicion had gonioscopically narrow angles (Shaffer grade ≤2 in three or more quadrants). Those with narrow angles were significantly older (P=0.004) than their open angle counterparts, but the two groups did not differ in terms of gender, refraction, IOP or CDR (all, P≥0.071). In a multivariate model including age, gender and refraction as predictors of angle grade (open or narrow), only age was a significant predictor of angle grade (P=0.004). Conclusions A large proportion of Chinese-Americans in our study population with glaucoma or glaucoma suspicion had gonioscopically narrow angles. In multivariate analysis, patients with narrow angles were older than those with open angles but did not differ from them in terms of gender or refraction. Continued evaluation of angle closure glaucoma risk among Chinese-Americans is needed. PMID:19826385

  16. Lattice Upgrade Plan for Crab Crossing at the KEKB Rings

    CERN Document Server

    Morita, Akio; Hosoyama, K; Koiso, Haruyo; Kubo, T; Masuzawa, Mika; Ohmi, Kazuhito; Oide, Katsunobu; Sugahara, Ryuhei; Yoshida, Masato

    2005-01-01

    We plan to install two superconducting crab cavities into the rings at Janyary, 2006. In our plan, we will install one crab cavity per one ring into the NIKKO straight section where the cryogenic infrastructure is already operated for the superconducting accelerating cavities. In order to obtain the correct crabbing angle at the interaction point(IP), we have to enlarge the horizontal beta function(200m for HER) and have to adjust the horizontal phase advance between the IP and the cavity installation point. In this paper, we will report the lattice modified for the crab crossing and the study results about the single beam dynamics.

  17. C-N Bond Activation and Ring Opening of a Saturated N-Heterocyclic Carbene by Lateral Alkali-Metal-Mediated Metalation.

    Science.gov (United States)

    Hernán-Gómez, Alberto; Kennedy, Alan R; Hevia, Eva

    2017-06-01

    Combining alkali-metal-mediated metalation (AMMM) and N-heterocyclic carbene (NHC) chemistry, a novel C-N bond activation and ring-opening process is described for these increasingly important NHC molecules, which are generally considered robust ancillary ligands. Here, mechanistic investigations on reactions of saturated NHC SIMes (SIMes=[:C{N(2,4,6-Me 3 C 6 H 2 )CH 2 } 2 ]) with Group 1 alkyl bases suggest this destructive process is triggered by lateral metalation of the carbene. Exploiting co-complexation and trans-metal-trapping strategies with lower polarity organometallic reagents (Mg(CH 2 SiMe 3 ) 2 and Al(TMP)iBu 2 ), key intermediates in this process have been isolated and structurally defined. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. The impact of changing solar screen rotation angle and its opening aspect ratios on Daylight Availability in residential desert buildings

    KAUST Repository

    Sherif, Ahmed H.

    2012-11-01

    In desert sunny clear-sky regions solar penetration can become excessive. This can cause non-uniform daylight distribution, glare and high solar heat gain, affecting both visual and thermal comfort. Shading devices, such as solar screens, were usually used to diffuse and prevent direct solar penetration into spaces. This paper investigates the impact of changing solar screen axial rotation angle and screen opening aspect ratio on daylighting performance in a typical residential living room space under the desert sunny clear-sky. The larger aim is to arrive at efficient solar screen designs that suit the different orientations.The study was divided into three consecutive phases. In phase one, the effect of the two parameters on Daylight Availability was tested. The solar screen was axially rotated by three different angles at 10° increments. Also, the aspect ratio of the screen opening in both horizontal and vertical directions was changed systematically. Simulation was conducted using the annual Daylight Dynamic Performance Metrics (DDPMs). In phase two, the Annual Daylight Glare Probability (DGP) metric was evaluated for the cases that were found adequate in phase one. In the third phase, the annual solar energy transmittance through the screen was calculated for the cases that achieved acceptable performance in the two previous phases in order to identify the more energy efficient screens.Solar screens with openings having horizontal aspect ratios were found to be the most effective, while those with vertical aspect ratios were achieved the lowest performance. In the North orientation, since almost all the cases that were tested in this research provided acceptable daylighting performance, the designer now have a variety of options to choose from. Preference should be given to screen openings of horizontal aspect ratios, especially the 12:1 and 18:1 (H:V) screens that achieved the best performance where 92% of the space was " daylit" in comparison with only 53

  19. Fundamental Design Principles of Linear Collider Damping Rings, with an Application to CLIC

    CERN Document Server

    Potier, J P

    2000-01-01

    Damping Rings for Linear Colliders have to produce very small normalised emittances at a high repetition rate. A previous paper presented analytical expressions for the equilibrium emittance of an arc cell as a function of the deflection angle per dipole. In addition, an expression for the lattice parameters providing the minimum emittance, and a strategy to stay close to this, were proposed. This analytical approach is extended to the detailed design of Damping Rings, taking into account the straight sections and the damping wigglers. Complete rings, including wiggler and injection insections, were modelled with the MAD [1] program, and their performance was found to be in good agreement with the analytical calculation. With such an approach it is shown that a Damping Ring corresponding to the Compact Linear Collider (CLIC) parameters at 0.5 and 1 TeV centre-of-mass energy, and tunable for two different sets of emittance and injection repetition rate, can be designed using the same ring layout.

  20. Accuracy of a new ring-opening metathesis elastomeric dental impression material with spray and immersion disinfection.

    Science.gov (United States)

    Kronström, Mats H; Johnson, Glen H; Hompesch, Richard W

    2010-01-01

    A new elastomeric impression material has been formulated with a ring-opening metathesis chemistry. In addition to other properties of clinical significance, the impression accuracy must be confirmed. The purpose of this study was to compare the accuracy of the new elastomeric impression material with vinyl polysiloxane and polyether following both spray and immersion disinfection. Impressions of a modified dentoform with a stainless steel crown preparation in the lower right quadrant were made, and type IV gypsum working casts and dies were formed. Anteroposterior (AP), cross-arch (CA), buccolingual (BL), mesiodistal (MD), occlusogingivobuccal (OGB), and occlusogingivolingual (OGL) dimensions were measured using a microscope. Working cast and die dimensions were compared to those of the master model. The impression materials were a newly formulated, ring-opening metathesis-polymerization impression material (ROMP Cartridge Tray and ROMP Volume Wash), vinyl polysiloxane (VPS, Aquasil Ultra Monophase/LV), and a polyether (PE, Impregum Penta Soft/Permadyne Garant L). Fifteen impressions with each material were made, of which 5 were disinfected by spray for 10 minutes (CaviCide), 5 were disinfected by immersion for 90 minutes (ProCide D), and 5 were not disinfected. There were significant cross-product interactions with a 2-way ANOVA, so a 1-way ANOVA and Dunnett's T3 multiple comparison test were used to compare the dimensional changes of the 3 impression materials, by disinfection status and for each location (alpha=.05). For ROMP, there were no significant differences from the master, for any dimension, when comparing the control and 2 disinfectant conditions. No significant differences were detected among the 3 impression materials for CA, BL, and MD. The working die dimensions of OGB and OGL for VPS with immersion disinfection were significantly shorter than with PE and ROMP (P<.05). Overall, the AP dimension was more accurate than CA, and the BL of working dies

  1. Anterior lamina cribrosa insertion in primary open-angle glaucoma patients and healthy subjects.

    Directory of Open Access Journals (Sweden)

    Kyoung Min Lee

    Full Text Available To determine using swept-source optical coherence tomography (SS-OCT whether there are differences in the location of the anterior lamina cribrosa insertion (ALI in primary open-angle glaucoma (POAG patients and healthy subjects.Fifty three eyes from 53 patients with POAG, and 53 eyes from 53 age-matched healthy subjects were included prospectively in Seoul National University Bundang Hospital. Twelve radial line B-scans centered on the optic disc in every half-clock-hour meridian were acquired using SS-OCT. The ALI position was assessed by measuring two parameters: (1 ALI distance (ALID--the distance from the anterior scleral canal opening (ASCO to the ALI; and (2 marginal anterior lamina cribrosa surface depth (mALCSD--the perpendicular distance from the ASCO plane to the anterior lamina cribrosa surface. These parameters were compared between the two groups for each meridian.Both ALID (256 ± 54 vs. 209 ± 37 µm, mean ± SD, p < 0.001 and mALCSD (232 ± 63 vs. 187 ± 40 µm, p < 0.001 were significantly greater in the POAG group than in the normal group. The largest difference was observed at the 6.5 o'clock and 11.5 o'clock meridians for both ALID and mALCSD. Multiple regression analysis revealed a negative correlation between age and both ALID and mALCSD in the control group, and a negative correlation between mean deviation of the visual field test and both ALID and mALCSD in the POAG group.The ALI was displaced posteriorly in eyes with POAG compared to those of healthy controls. This finding suggests that the posteriorly located lamina cribrosa insertion is an important component of glaucomatous optic nerve excavation.

  2. Diode laser trabeculoplasty in open angle glaucoma: 50 micron vs. 100 micron spot size.

    Science.gov (United States)

    Veljko, Andreić; Miljković, Aleksandar; Babić, Nikola

    2011-01-01

    The study was aimed at evaluating the efficacy of diode laser trabeculoplsaty in lowering intraocular pressure in patients with both primary open-angle glaucoma and exfoliation glaucoma by using different size of laser spot. This six-month, unmasked, controlled, prospective study included sixty-two patients with the same number of eyes, who were divided into two groups. Trabeculoplasty was performed with 50 micron and 100 micron laser spot size in the group I and group II, respectively. Other laser parameters were the same for both groups: the wave length of 532 nm, 0.1 second single emission with the power of 600-1200 mW was applied on the 180 degrees of the trabeculum. The mean intraocular pressure decrease in the 50 micron group (group 1) on day 7 was 24% from the baseline and after six-month follow-up period the intraocular pressure decrease was 29.8% (p < 0.001). In the 100 micron group (group II), the mean intraocular pressure decrease on day 7 was 26.5% and after six months it was 39% (p < 0.001).

  3. Angle parameter changes of phacoemulsification and combined phacotrabeculectomy for acute primary angle closure

    Directory of Open Access Journals (Sweden)

    Shi-Wei Li

    2015-08-01

    Full Text Available AIM: To evaluate the difference in angle parameters and clinical outcome following phacoemulsification and combined phacotrabeculectomy in patients with acute primary angle closure (APAC using ultrasound biomicroscopy (UBM.METHODS: Patients (n=23, 31 eyes were randomized to receive phacoemulsification or combined phacotrabeculectomy (n=24, 31 eyes. Best-corrected visual acuity (BCVA, intraocular pressure (IOP, the main complications following surgery, and indentation gonioscopy and angle parameters measured using UBM were documented preoperatively and postoperatively.RESULTS:The improvement in BCVA in the phacoemulsification group was significantly greater than in the combined group (P<0.05. IOP in the phacoemulsification group was slightly higher than in the combined group following 1wk of follow-up (P<0.05, whereas there was no significant difference between the two groups at the latter follow-up (P>0.05. Phacoemulsification alone resulted in a slight increase in the trabecular ciliary processes distance compared with the combined surgery (P<0.05, whereas the other angle parameters showed no significant difference between the groups. Complications in combined group were greater than phacoemulsification only group.CONCLUSION:Both surgeries effectively opened the drainage angle and deepened the anterior chamber, and IOP was well controlled postoperatively. However, phacoemulsification showed better efficacy in improving visual function and showed reduced complications following surgery.

  4. Preparation of open tubular capillary columns by in situ ring-opening polymerization and their applications in cLC-MS/MS analysis of tryptic digest.

    Science.gov (United States)

    Wang, Hongwei; Yao, Yating; Li, Ya; Ma, Shujuan; Peng, Xiaojun; Ou, Junjie; Ye, Mingliang

    2017-08-01

    An open tubular (OT) column (25 μm i.d.) was prepared by in situ ring-opening polymerization of octaglycidyldimethylsilyl polyhedral oligomeric silsesquioxanes (POSS-epoxy) with 4-aminophenyl disulfide (APDS) in a binary porogenic system of ethanol/H 2 O. It was found that porogenic composition played an important role in the formation of OT stationary phases. The ratio of ethanol/H 2 O at 6/1 (v/v) would lead to the fabrication of hybrid monoliths, while the ratio of ethanol/H 2 O at 13/1 (v/v) would result in the synthesis of OT phases. In addition, the effects of precursor content and reaction duration on the thickness of OT stationary phases were investigated. Either lower precursor content or shorter reaction duration would produce thinner layer of OT column. The repeatability of OT columns was evaluated through relative standard deviation (RSD%) with benzene as the analyte. The run-to-run, column-to-column and batch-to-batch repeatabilities were 1.7%, 4.8% and 5.6%, respectively, exhibiting satisfactory repeatability of the OT column. Then tryptic digest of mouse liver proteins was used to evaluate the performance of the resulting OT columns (25 μm i.d. × 2.5 m in length) by cLC-MS/MS analysis, demonstrating their potential in proteome analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Measurement of Systematic Error Effects for a Sensitive Storage Ring EDM Polarimeter

    Science.gov (United States)

    Imig, Astrid; Stephenson, Edward

    2009-10-01

    The Storage Ring EDM Collaboration was using the Cooler Synchrotron (COSY) and the EDDA detector at the Forschungszentrum J"ulich to explore systematic errors in very sensitive storage-ring polarization measurements. Polarized deuterons of 235 MeV were used. The analyzer target was a block of 17 mm thick carbon placed close to the beam so that white noise applied to upstream electrostatic plates increases the vertical phase space of the beam, allowing deuterons to strike the front face of the block. For a detector acceptance that covers laboratory angles larger than 9 ^o, the efficiency for particles to scatter into the polarimeter detectors was about 0.1% (all directions) and the vector analyzing power was about 0.2. Measurements were made of the sensitivity of the polarization measurement to beam position and angle. Both vector and tensor asymmetries were measured using beams with both vector and tensor polarization. Effects were seen that depend upon both the beam geometry and the data rate in the detectors.

  6. [Computer-assisted multimedia interactive learning program "Primary Open-Angle Glaucoma"].

    Science.gov (United States)

    Dick, V B; Zenz, H; Eisenmann, D; Tekaat, C J; Wagner, R; Jacobi, K W

    1996-05-01

    Advances in the area of information technology have opened up new possibilities for the use of interactive media in the training of medical students. Classical instructional technologies, such as video, slides, audio cassettes and computer programs with a textbook orientation, have been merged into one multimedia computer system. The medical profession has been increasingly integrating computer-based applications which can be used, for example, for record keeping within a medical practice. The goal of this development is to provide access to all modes of information storage and retrieval as well as documentation and training systems within a specific context. Since the beginning of the winter semester 1995, the Department of Ophthalmology in Giessen has used the learning program "Primary Open Angle Glaucoma" in student instruction. One factor that contributed to the implementation of this project was that actual training using patients within the clinic is difficult to conduct. Media-supported training that can provide a simulation of actual practice offers a suitable substitute. The learning program has been installed on Power PCs (Apple MacIntosh), which make up the technical foundation of our system. The program was developed using Hypercard software, which provides userfriendly graphical work environment. This controls the input and retrieval of data, direct editing of documents, immediate simulation, the creation of on-screen documents and the integration of slides that have been scanned in as well as QuickTime films. All of this can be accomplished without any special knowledge of programming language or operating systems on the part of the user. The glaucoma learning program is structured along the lines of anatomy, including an explanation of the circulation of the aqueous humor, pathology, clinical symptoms and findings, diagnosis and treatment. This structure along with the possibility for creating a list of personal files for the user with a collection

  7. RF-to-RF Characterization of a Phased Array Receive Antenna Steering System Using a Novel Ring Resonator-Based Integrated Photonic Beamformer

    NARCIS (Netherlands)

    Zhuang, L.; Burla, M.; Roeloffzen, C.G.H.; Meijerink, Arjan; Marpaung, D.A.I.; Khan, M.R.H.; van Etten, Wim; Leinse, Arne; Hoekman, M.; Heideman, Rene

    2009-01-01

    A novel ring resonator-based photonic beamformer has been developed for continuous and squint-free control of the reception angle of broadband phased array antenna systems. The core of the system is a ring resonator based optical beamforming network (OBFN) used for delay synchronization and coherent

  8. Exactly complete solutions of the Schroedinger equation with a spherically harmonic oscillatory ring-shaped potential

    International Nuclear Information System (INIS)

    Zhang Mincang; Sun Guohua; Dong Shihai

    2010-01-01

    A spherically harmonic oscillatory ring-shaped potential is proposed and its exactly complete solutions are presented by the Nikiforov-Uvarov method. The effect of the angle-dependent part on the radial solutions is discussed.

  9. Personality assessment based on the five-factor model of personality structure in patients with primary open-angle glaucoma.

    Science.gov (United States)

    Mabuchi, Fumihiko; Yoshimura, Kimio; Kashiwagi, Kenji; Shioe, Kunihiko; Kanba, Shigenobu; Iijima, Hiroyuki; Tsukahara, Shigeo

    2005-01-01

    Several characteristic personality types have been reported for glaucoma patients in previous studies. However, none of the previous studies used a common structural theory of personality. In this study, we conducted a multicenter cross-sectional case-control study using the recently established five-factor model of personality structure. Personality was evaluated using the Neuroticism Extraversion Openness Five-Factor Inventory (NEO-FFI), which is a questionnaire specifically designed to test the five-factor model of personality: neuroticism (N), extraversion (E), openness (O), agreeableness (A), and conscientiousness (C). Eligible questionnaires were obtained from 196 patients with primary open-angle glaucoma (POAG) (99 men, 97 women) and 223 reference subjects with no ocular disease except cataract (87 men, 136 women). The mean score of each NEO-FFI factor for POAG patients was compared to the scores for the reference subjects. Compared with the reference subjects, the mean N score was significantly higher (P = 0.013), the mean scores for A and C were significantly lower (P = 0.007 and P = 0.001, respectively), and the mean E score tended to be lower (P = 0.055) in male POAG patients. The mean E score was significantly lower (P = 0.023) in female POAG patients. Characteristic personality traits were noted in POAG patients, and a more significant relationship was found between personality and glaucoma in men than in women.

  10. Optimal control of quantum rings by terahertz laser pulses.

    Science.gov (United States)

    Räsänen, E; Castro, A; Werschnik, J; Rubio, A; Gross, E K U

    2007-04-13

    Complete control of single-electron states in a two-dimensional semiconductor quantum-ring model is established, opening a path into coherent laser-driven single-gate qubits. The control scheme is developed in the framework of optimal-control theory for laser pulses of two-component polarization. In terms of pulse lengths and target-state occupations, the scheme is shown to be superior to conventional control methods that exploit Rabi oscillations generated by uniform circularly polarized pulses. Current-carrying states in a quantum ring can be used to manipulate a two-level subsystem at the ring center. Combining our results, we propose a realistic approach to construct a laser-driven single-gate qubit that has switching times in the terahertz regime.

  11. Containing Ebola at the Source with Ring Vaccination.

    Directory of Open Access Journals (Sweden)

    Stefano Merler

    2016-11-01

    Full Text Available Interim results from the Guinea Ebola ring vaccination trial suggest high efficacy of the rVSV-ZEBOV vaccine. These findings open the door to the use of ring vaccination strategies in which the contacts and contacts of contacts of each index case are promptly vaccinated to contain future Ebola virus disease outbreaks. To provide a numerical estimate of the effectiveness of ring vaccination strategies we introduce a spatially explicit agent-based model to simulate Ebola outbreaks in the Pujehun district, Sierra Leone, structurally similar to previous modelling approaches. We find that ring vaccination can successfully contain an outbreak for values of the effective reproduction number up to 1.6. Through an extensive sensitivity analysis of parameters characterising the readiness and capacity of the health care system, we identify interventions that, alongside ring vaccination, could increase the likelihood of containment. In particular, shortening the time from symptoms onset to hospitalisation to 2-3 days on average through improved contact tracing procedures, adding a 2km spatial component to the vaccination ring, and decreasing human mobility by quarantining affected areas might contribute increase our ability to contain outbreaks with effective reproduction number up to 2.6. These results have implications for future control of Ebola and other emerging infectious disease threats.

  12. Effects of thermal history in the ring opening polymerization of CBT and its mixtures with montmorillonite on the crystallization of the resulting poly(butylene terephthalate)

    Energy Technology Data Exchange (ETDEWEB)

    Lanciano, Giuseppina [Department of Innovation Engineering, University of Salento, Via per Arnesano, 73100 Lecce (Italy); Greco, Antonio, E-mail: antonio.greco@unile.it [Department of Innovation Engineering, University of Salento, Via per Arnesano, 73100 Lecce (Italy); Maffezzoli, Alfonso [Department of Innovation Engineering, University of Salento, Via per Arnesano, 73100 Lecce (Italy); Mascia, Leno [Department of Materials, Loughborough University, Loughborough, LE 11 3TU (United Kingdom)

    2009-09-10

    Differential scanning calorimetry was used to study the thermal characteristics and morphological structure of species produced during the ring opening polymerization of cyclic butylene terephthalate (CBT). Thermal programs consisting of a first ramp heating scan and an isothermal step, followed by cooling and a second ramp heating step, were used to study the effects of thermal history, catalyst (butyl chlorotin dihydroxide) at concentrations between 0.1 and 1.3% (w/w), and the presence of a layered silicate nanofiller (montmorillonite at 4.0%, w/w) on the structure of the resulting polymer (poly(butylene terephthalate), pCBT). Wide angle X-ray diffraction was used to monitor the degree of exfoliation of the nanocomposites. It was found that pCBT is formed in the amorphous state, and crystallizes during the heating step or during the isothermal step at temperatures lower than the equilibrium melting temperature of the polymer (T{sub m}{sup 0}). When premixed with the nanofiller, irrespective of whether this was previously intercalated with a tallow surfactant or used in its pristine form, polymerization took place at higher temperatures and most of the crystallization was found to occur during the cooling stage. In those cases where crystallization took place during either the first heating scan, or during a prolonged isothermal step below the T{sub m}{sup 0} of the polymer, the resulting crystals were found to have a higher lamellar thickness, as compared with the same polymer crystallized from the melt during the cooling step from temperatures above the polymer T{sub m}{sup 0}.

  13. Effects of thermal history in the ring opening polymerization of CBT and its mixtures with montmorillonite on the crystallization of the resulting poly(butylene terephthalate)

    International Nuclear Information System (INIS)

    Lanciano, Giuseppina; Greco, Antonio; Maffezzoli, Alfonso; Mascia, Leno

    2009-01-01

    Differential scanning calorimetry was used to study the thermal characteristics and morphological structure of species produced during the ring opening polymerization of cyclic butylene terephthalate (CBT). Thermal programs consisting of a first ramp heating scan and an isothermal step, followed by cooling and a second ramp heating step, were used to study the effects of thermal history, catalyst (butyl chlorotin dihydroxide) at concentrations between 0.1 and 1.3% (w/w), and the presence of a layered silicate nanofiller (montmorillonite at 4.0%, w/w) on the structure of the resulting polymer (poly(butylene terephthalate), pCBT). Wide angle X-ray diffraction was used to monitor the degree of exfoliation of the nanocomposites. It was found that pCBT is formed in the amorphous state, and crystallizes during the heating step or during the isothermal step at temperatures lower than the equilibrium melting temperature of the polymer (T m 0 ). When premixed with the nanofiller, irrespective of whether this was previously intercalated with a tallow surfactant or used in its pristine form, polymerization took place at higher temperatures and most of the crystallization was found to occur during the cooling stage. In those cases where crystallization took place during either the first heating scan, or during a prolonged isothermal step below the T m 0 of the polymer, the resulting crystals were found to have a higher lamellar thickness, as compared with the same polymer crystallized from the melt during the cooling step from temperatures above the polymer T m 0 .

  14. Diagnostic capability of optic nerve head rim width and retinal nerve fiber thickness in open-angle glaucoma.

    Science.gov (United States)

    Di Staso, Silvio; Agnifili, Luca; Di Staso, Federico; Climastone, Hilary; Ciancaglini, Marco; Scuderi, Gian Luca

    2018-03-01

    This study was performed to test the diagnostic capability of the minimum rim width compared to peripapillary retinal nerve fiber layer thickness in patients with glaucoma. A case control, observer masked study, was conducted. Minimum rim width and retinal nerve fiber layer thickness were assessed using the patient-specific axis traced between fovea-to-Bruch's membrane opening center axis. For both minimum rim width and retinal nerve fiber layer thickness, the regionalization in six sectors (nasal, superior-nasal, superior-temporal, temporal, inferior-temporal, and inferior-nasal) was analyzed. Eyes with at least one sector with value below the 5% or 1% normative limit of the optical coherence tomography normative database were classified as glaucomatous. The area under the receiver operator characteristic curve, the accuracy, sensitivity, specificity, and predictive positive and negative values were calculated for both minimum rim width and retinal nerve fiber layer thickness. A total of 118 eyes of 118 Caucasian subjects (80 eyes with open-angle glaucoma and 38 control eyes) were enrolled in the study. Accuracy, sensitivity, and specificity were 79.7%, 77.5%, and 84.2%, respectively, for minimum rim width and 84.7%, 82.5%, and 89.5% for retinal nerve fiber layer thickness. The positive predictive values were 0.91% and 0.94% for minimum rim width and retinal nerve fiber layer thickness, respectively, whereas the negative predictive values were 0.64% and 0.70%. The area under the receiver operator characteristic curve was 0.892 for minimum rim width and 0.938 for retinal nerve fiber layer thickness. Our results indicated that the sector analysis based on Bruch's membrane opening and fovea to disk alignment is able to detect glaucomatous defects, and that Bruch's membrane opening minimum rim width and retinal nerve fiber layer thickness showed equivalent diagnostic ability.

  15. Ring Theory

    CERN Document Server

    Jara, Pascual; Torrecillas, Blas

    1988-01-01

    The papers in this proceedings volume are selected research papers in different areas of ring theory, including graded rings, differential operator rings, K-theory of noetherian rings, torsion theory, regular rings, cohomology of algebras, local cohomology of noncommutative rings. The book will be important for mathematicians active in research in ring theory.

  16. A Computer Vision Approach to Identify Einstein Rings and Arcs

    Science.gov (United States)

    Lee, Chien-Hsiu

    2017-03-01

    Einstein rings are rare gems of strong lensing phenomena; the ring images can be used to probe the underlying lens gravitational potential at every position angles, tightly constraining the lens mass profile. In addition, the magnified images also enable us to probe high-z galaxies with enhanced resolution and signal-to-noise ratios. However, only a handful of Einstein rings have been reported, either from serendipitous discoveries or or visual inspections of hundred thousands of massive galaxies or galaxy clusters. In the era of large sky surveys, an automated approach to identify ring pattern in the big data to come is in high demand. Here, we present an Einstein ring recognition approach based on computer vision techniques. The workhorse is the circle Hough transform that recognise circular patterns or arcs in the images. We propose a two-tier approach by first pre-selecting massive galaxies associated with multiple blue objects as possible lens, than use Hough transform to identify circular pattern. As a proof-of-concept, we apply our approach to SDSS, with a high completeness, albeit with low purity. We also apply our approach to other lenses in DES, HSC-SSP, and UltraVISTA survey, illustrating the versatility of our approach.

  17. Ray-tracing studies for a whole-viewing-angle retroreflector

    International Nuclear Information System (INIS)

    Yang, B.; Friedsam, H.

    2000-01-01

    The APS Survey and Alignment team uses LEICA laser trackers for the majority of their alignment tasks. These instruments utilize several different retroreflectors for tracking the path of the laser interferometer. Currently in use are open-air corner cubes with an acceptance angle of ±20 degree, corner cube prisms with an acceptance angle of ±50degree, and a Cat's eye with an acceptance angle of ±60degree. Best measurement results can be achieved by using an open-air corner cube that eliminates the need for the laser beam to travel through a different medium before it returns to the instrument detector. However, the trade off is a small acceptance angle. In order to overcome the limitations of the small acceptance angles, Takatsuji et al. has proposed the creation of a full-viewing-angle retroreflector. Based on the notion that the radius R 1 of a common Cat's eye is proportional to R 2 , one can write: R 1 = (n minus 1)R 2 . In the case that n, the refractive index of glass, equals 2, the radii R 1 and R 2 are identical, and one can create a solid sphere Cat's eye. This design has the advantages that no adhesives are used to bond the two hemispheres together, misalignments between the hemispheres are not an issue, and most importantly, larger acceptance angles are possible. This paper shows the results of their ray tracing calculations characterizing the geometrical optics

  18. Preparation of polyhedral oligomeric silsesquioxane based hybrid monoliths by ring-opening polymerization for capillary LC and CEC.

    Science.gov (United States)

    Lin, Hui; Zhang, Zhenbin; Dong, Jing; Liu, Zhongshan; Ou, Junjie; Zou, Hanfa

    2013-09-01

    A new organic-inorganic hybrid monolith was prepared by the ring-opening polymerization of octaglycidyldimethylsilyl polyhedral oligomeric silsesquioxane (POSS) with 1,4-butanediamine (BDA) using 1-propanol, 1,4-butanediol, and PEG 10,000 as a porogenic system. Benefiting from the moderate phase separation process, the resulting poly(POSS-co-BDA) hybrid monolith possessed a uniform microstructure and exhibited excellent performance in chromatographic applications. Neutral, acidic, and basic compounds were successfully separated on the hybrid monolith in capillary LC (cLC), and high column efficiencies were achieved in all of the separations. In addition, as the amino groups could generate a strong EOF, the hybrid monolith was also applied in CEC for the separation of neutral and polar compounds, and a satisfactory performance was obtained. These results demonstrate that the poly(POSS-co-BDA) hybrid monolith is a good separation media in chromatographic separations of various types of compounds by both cLC and CEC. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Effect of torsion angle on electronic transport through different anchoring groups in molecular junction

    International Nuclear Information System (INIS)

    Xia Caijuan; Fang Changfeng; Zhao Peng; Xie Shijie; Liu Desheng

    2009-01-01

    By applying nonequilibrium Green's function formalism combined with first-principles density functional theory, we investigate effect of torsion angle on electronic transport properties of 4,4 ' -biphenyl molecule connected with different anchoring groups (dithiocarboxylate and thiol group) to Au(111) electrodes. The influence of the HOMO-LUMO gaps and the spatial distributions of molecular orbitals on the quantum transport through the molecular device are discussed. Theoretical results show that the torsion angle plays important role in conducting behavior of molecular devices. By changing the torsion angle between two phenyl rings, namely changing the magnitude of the intermolecular coupling effect, a different transport behavior can be observed in these two systems.

  20. Clinical results with the Trabectome, a novel surgical device for treatment of open-angle glaucoma.

    Science.gov (United States)

    Minckler, Don; Baerveldt, George; Ramirez, Marina Alfaro; Mosaed, Sameh; Wilson, Richard; Shaarawy, Tarek; Zack, Barend; Dustin, Laurie; Francis, Brian

    2006-01-01

    To describe treatment outcomes after Trabectome surgery in an initial series of 101 patients with open-angle glaucoma. A 19-gauge microelectrosurgical device enabled ab interno removal of a strip of trabecular meshwork and inner wall of Schlemm's canal under gonioscopic control with continual infusion and foot-pedal control of aspiration and electrosurgery. A smooth, pointed ceramic-coated insulating footplate was inserted into Schlemm's canal to act as a guide within the canal and to protect adjacent structures from mechanical or heat injury during ablation of a 30- to 90-degree arc of angle tissue. Mean preoperative intraocular pressure (IOP) in the initial 101 patients was 27.6 +/- 7.2 mm Hg. Thirty months postoperatively, mean IOP was 16.3 +/- 3.3 mm Hg (n = 11). The mean percentage drop over the whole course of follow-up was 40%. At all times postoperatively, the absolute and percent decrease in IOP from preoperative levels were statistically significant (paired t test, P < .0001). Overall success (IOP

  1. A correlation for safety valve blowdown and ring settings

    International Nuclear Information System (INIS)

    Singh, A.; Shak, D.

    1982-01-01

    The blowdown of a spring loaded safety valve is defined as the difference between the pressure at which the valve opens and the pressure at which the valve fully closes under certain fluid flow conditions. Generally, the blowdown is expressed in terms of percentage of the opening pressure. An extensive series of tests carried out in the EPRI/PWR Utilities Valve Test Program has shown that the blowdown of safety valves can in general be strongly dependent upon the valve geometry and other parameters such as ring adjustments, spring stiffness, backpressure etc. In the present study, correlations have been developed using the EPRI safety valve test data to predict the expected blowdown as a function of adjustment ring settings for geometrically similar valves under steam discharge conditions. The correlation is validated against two different size Dresser valves

  2. Development of a circular shape Si-PM-based detector ring for breast-dedicated PET system

    Science.gov (United States)

    Nakanishi, Kouhei; Yamamoto, Seiichi; Watabe, Hiroshi; Abe, Shinji; Fujita, Naotoshi; Kato, Katsuhiko

    2018-02-01

    In clinical situations, various breast-dedicated positron emission tomography (PET) systems have been used. However, clinical breast-dedicated PET systems have polygonal detector ring. Polygonal detector ring sometimes causes image artifact, so complicated reconstruction algorithm is needed to reduce artifact. Consequently, we developed a circular detector ring for breast-dedicated PET to obtain images without artifact using a simple reconstruction algorithm. We used Lu1.9Gd0.1SiO5 (LGSO) scintillator block which was made of 1.5 x 1.9 x 15 mm pixels that were arranged in an 8 x 24 matrix. As photodetectors, we used silicon photomultiplier (Si-PM) arrays whose channel size was 3 x 3 mm. A detector unit was composed of four scintillator blocks, 16 Si-PM arrays and a light guide. The developed detector unit had angled configuration since the light guide was bending. A detector unit had three gaps with an angle of 5.625° between scintillator blocks. With these configurations, we could arrange 64 scintillator blocks in nearly circular shape (regular 64-sided polygon) using 16 detector units. The use of the smaller number of detector units could reduce the size of the front-end electronics circuits. The inner diameter of the developed detector ring was 260 mm. This size was similar to those of brain PET systems, so our breast-dedicated PET detector ring can measure not only breast but also brain. Measured radial, tangential and axial spatial resolution of the detector ring reconstructed by the filtered back-projection (FBP) algorithm were 2.1 mm FWHM, 2.0 mm FWHM and 1.7 mm FWHM at center of field of view (FOV), respectively. The sensitivity was 2.0% at center of the axial FOV. With the developed detector ring, we could obtain high resolution image of the breast phantom and the brain phantom. We conclude that our developed Si-PM-based detector ring is promising for a high resolution breast-dedicated PET system that can also be used for brain PET system.

  3. Electromagnetic Power Harvester Using Wide-Angle and Polarization-Insensitive Metasurfaces

    Directory of Open Access Journals (Sweden)

    Xuanming Zhang

    2018-03-01

    Full Text Available A new wide-angle and polarization-insensitive metasurface (MS instead of traditional antenna is built as the primary ambient energy harvester in this paper. The MS is a two-dimensional energy harvesting array that is composed of subwavelength electrical small ring resonator that is working at 2.5 GHz (LTE/WiFi. In the case of different polarization and incidence angles, we demonstrate the metasurface can achieve high harvesting efficiency of 90%. The fabricated prototype of 9 × 9 MS energy harvesting array is measured, and the experimental results validate that the proposed MS has a good performance more than 80% of energy harvesting efficiency for arbitrary polarization and wide-angle incident waves. The good agreement of the simulation with the experiment results verifies the practicability and effectiveness of the proposed MS structure, which will provide a new source of supply in wireless sensor networks (WSN.

  4. Energetic ion injection and formation of the storm-time symmetric ring current

    Directory of Open Access Journals (Sweden)

    L. Xie

    2006-12-01

    Full Text Available An extensive study of ring current injection and intensification of the storm-time ring current is conducted with three-dimensional (3-D test particle trajectory calculations (TPTCs. The TPTCs reveal more accurately the process of ring current injection, with the main results being the following: (1 an intense convection electric field can effectively energize and inject plasma sheet particles into the ring current region within 1–3 h. (2 Injected ions often follow chaotic trajectories in non-adiabatic regions, which may have implications in storm and ring current physics. (3 The shielding electric field, which arises as a consequence of enhanced convection and co-exists with the injection and convection electric field, may cause the original open trajectories of injected ions with higher energy to change into closed ones, thus playing a role in the formation of the symmetric ring current.

  5. Assessment of narrow angles by gonioscopy, Van Herick method and anterior segment optical coherence tomography.

    Science.gov (United States)

    Park, Seong Bae; Sung, Kyung Rim; Kang, Sung Yung; Jo, Jung Woo; Lee, Kyoung Sub; Kook, Michael S

    2011-07-01

    To evaluate anterior chamber (AC) angles using gonioscopy, Van Herick technique and anterior segment optical coherence tomography (AS-OCT). One hundred forty-eight consecutive subjects were enrolled. The agreement between any two of three diagnostic methods, gonioscopy, AS-OCT and Van Herick, was calculated in narrow-angle patients. The area under receiver-operating characteristic curves (AUC) for discriminating between narrow and open angles determined by gonioscopy was calculated in all participants for AS-OCT parameter angle opening distance (AOD), angle recess area, trabecular iris surface area and anterior chamber depth (ACD). As a subgroup analysis, capability of AS-OCT parameters for detecting angle closure defined by AS-OCT was assessed in narrow-angle patients. The agreement between the Van Herick method and gonioscopy in detecting angle closure was excellent in narrow angles (κ = 0.80, temporal; κ = 0.82, nasal). However, agreement between gonioscopy and AS-OCT and between the Van Herick method and AS-OCT was poor (κ = 0.11-0.16). Discrimination capability of AS-OCT parameters between open and narrow angles determined by gonioscopy was excellent for all AS-OCT parameters (AUC, temporal: AOD500 = 0.96, nasal: AOD500 = 0.99). The AUCs for detecting angle closure defined by AS-OCT image in narrow angle subjects was good for all AS-OCT parameters (AUC, 0.80-0.94) except for ACD (temporal: ACD = 0.70, nasal: ACD = 0.63). Assessment of narrow angles by gonioscopy and the Van Herick technique showed good agreement, but both measurements revealed poor agreement with AS-OCT. The angle closure detection capability of AS-OCT parameters was excellent; however, it was slightly lower in ACD.

  6. Serotonin levels in aqueous humor of patients with primary open-angle glaucoma.

    Science.gov (United States)

    Zanon-Moreno, V; Melo, P; Mendes-Pinto, M M; Alves, C J; Garcia-Medina, J J; Vinuesa-Silva, I; Moreno-Nadal, M A; Pinazo-Duran, M D

    2008-01-01

    Glaucoma is an optic neuropathy characterized by a high intraocular pressure (IOP), alterations in optic nerve head, and loss of visual field that could lead to bilateral blindness. Serotonin (5-HT) is a biogenic monoamine that is synthesized from hydroxylation of tryptophan and acts by three ways, dissemination, metabolism, and reuptake in synaptic cleft through specific systems of the membrane. The purpose of this study is to evaluate the 5-HT and 5-HIAA (5-hydroxiindolacetic acid) levels in the aqueous humor of patients with primary open-angle glaucoma (POAG). We performed a case-control study, and the patients recruited were classified into two groups, 1) 30 patients with POAG (GG) and 2) 30 patients with cataracts (CG), who acted as the controls. Aqueous humor samples of each patient were obtained by paracentesis at the beginning of the surgical procedures. 5-HT and 5-HIAA levels were determined by high performance liquid chromatography (HPLC) with electrochemical detection. There were no statistical differences between age (71.3 +/- 7.2 years in GG, 73.5 +/- 9.0 years in CG; p=0.2581) or gender (sex ratio 0.765 in GG and 0.667 in CG). 5-HT levels were lower in GG, but this difference was not significant (p=0.820). We observed a statistically significant higher level of 5-HIAA in GG (p=0.001). The 5-HT turnover (5-HIAA/5-HT) were higher in GG than in CG (pCG patients.

  7. Prevalence of Primary Open Angle Glaucoma in Obstructive Sleep Apnea Syndrome

    Directory of Open Access Journals (Sweden)

    Mohammad Raza Besharati

    2014-01-01

    Full Text Available Background: Obstructive sleep apnea (OSA is partial or complete recurrent upper airway obstructions during sleep. Reduction in blood flow of the optic nerve head is an important causative factor in glaucoma. The objective of this study is to determine the prevalence of primary open angle glaucoma (POAG in OSA patients. Materials and Methods: From September 2009 to January 2010 in this descriptive-analytic cross sectional study, 90 cases of patients with OSA referred to Yazd Shahid Sadoughi hospital were collected and studied by polysomnography, blood gas analysis and ocular examination including measurement of intra ocular pressure, gonioscopy, fondoscopy and automated perimetry. Statistical analysis was performed by SPSS software6T. Results: Thirty-one patients had mild OSA, 30 patients had moderate OSA and 29 patients had severe OSA. The prevalence of POAG in this group of patients was 10% (95% CI: 4-16. It is higher than the general population in the same age group (p=0.017. There was no significant correlation between the presence of glaucoma and apnea hypopnea index (AHI, mean saturation arterial OR2R (MSaOR2R, body mass index (BMI, sex and age. A significant correlation between AHI with IOP and cup/disc ratio was not documented6T. Conclusion: According to our founding, the prevalence of POAG in OSA patients was higher than the general population in the same age group. Thus we recommend screening of glaucoma in OSA patients. This Study suggests that AHI, MSaOR2R, BMI, sex or age are not important risk factors for glaucoma in OSA patients6T

  8. Má oclusão Classe I de Angle, com mordida aberta anterior, tratada com extração de dentes permanentes Angle Class I malocclusion, with anterior open bite, treated with extraction of permanent teeth

    Directory of Open Access Journals (Sweden)

    Mírian Aiko Nakane Matsumoto

    2011-02-01

    Full Text Available A mordida aberta é uma anomalia com características distintas que, além da complexidade dos múltiplos fatores etiológicos, traz consequências estéticas e funcionais. Muitas alternativas têm sido utilizadas em seu tratamento, entre elas a grade palatina, forças ortopédicas, ajuste oclusal, camuflagem com ou sem exodontias, mini-implantes ou miniplacas e cirurgia ortognática. O diagnóstico preciso e a determinação da etiologia permitem estabelecer os objetivos e o plano de tratamento ideal para essa má oclusão. O presente relato descreve o tratamento de uma má oclusão Classe I de Angle, com padrão esquelético de Classe II e mordida aberta anterior, realizado em duas fases e que foi apresentado à diretoria do Board Brasileiro de Ortodontia e Ortopedia Facial (BBO, representando a categoria 2, como parte dos requisitos para a obtenção do título de Diplomado pelo BBO.Open bite is an anomaly with distinct characteristics which, in addition to involving complex, multiple etiologic factors, entails aesthetic and functional consequences. Many alternative approaches have been employed to treat open bite, including palatal crib, orthopedic forces, occlusal adjustment, camouflage with or without extractions, mini-implants or mini-plates, and orthognathic surgery. By determining accurate diagnosis and etiology professionals can set the goals and ideal treatment plan for this malocclusion. This report, describing the two stages treatment of a Angle Class I malocclusion with Class II skeletal pattern and anterior open bite, was presented to the Brazilian Board of Orthodontics and Dentofacial Orthopedics (BBO, representative of category 2, as partial fulfillment of the requirements for obtaining the title of BBO Diplomate.

  9. Three Toxic Heavy Metals in Open-Angle Glaucoma with Low-Teen and High-Teen Intraocular Pressure: A Cross-Sectional Study from South Korea

    OpenAIRE

    Lee, Si Hyung; Kang, Eun Min; Kim, Gyu Ah; Kwak, Seung Woo; Kim, Joon Mo; Bae, Hyoung Won; Seong, Gong Je; Kim, Chan Yun

    2016-01-01

    Background To investigate the association between heavy metal levels and open-angle glaucoma (OAG) with low- and high-teen baseline intraocular pressure (IOP) using a population-based study design. Methods This cross-sectional study included 5,198 participants older than 19 years of age who participated in the Korean National Health and Nutrition Examination Survey (KNHANES) from 2008 to 2012 and had blood heavy metal levels available. The OAG with normal baseline IOP (IOP ? 21 mmHg) subjects...

  10. Hypothyroidism as a risk factor for open angle glaucoma: A systematic review and meta-analysis

    Science.gov (United States)

    Liu, Yue; Zheng, Guangying

    2017-01-01

    Purpose The relationship between hypothyroidism and primary open angle glaucoma (POAG) has attracted intense interest recently, but the reported results have been controversial. This meta-analysis was carried out to determine the association between hypothyroidism and POAG. Methods The literature was identified from three databases (Web of Science, Embase, and PubMed). The meta-analyses were performed using random-effects models, with results reported as adjusted odds ratios (ORs) with 95% confidence intervals (CI 95%). Results A total of 11 studies meeting the inclusion criteria were included in the final meta-analysis. The pooled OR based on 11 risk estimates showed a statistically significant increased risk of POAG prevalence among individuals with hypothyroidism (OR = 1.64, 95% CI = 1.27–2.13). Substantial heterogeneity among these studies was detected (P hypothyroidism and POAG, which was not observed in cross-sectional studies. There was no significant publication bias in this study. Conclusions The findings of this meta-analysis indicate that individuals with hypothyroidism have an increased risk of developing POAG. PMID:29069095

  11. Ring and jet study on the azimuthal substructure of pions at CERN ...

    Indian Academy of Sciences (India)

    Abstract. We have presented an investigation on the ring- and jet-like azimuthal angle sub- structures in the emission of secondary charged hadrons coming from 32S–Ag/Br interactions at. 200 A GeV/c. Nuclear photographic emulsion technique has been employed to collect the exper- imental data. The presence of such ...

  12. Statistical analyses of the magnet data for the advanced photon source storage ring magnets

    International Nuclear Information System (INIS)

    Kim, S.H.; Carnegie, D.W.; Doose, C.; Hogrefe, R.; Kim, K.; Merl, R.

    1995-01-01

    The statistics of the measured magnetic data of 80 dipole, 400 quadrupole, and 280 sextupole magnets of conventional resistive designs for the APS storage ring is summarized. In order to accommodate the vacuum chamber, the curved dipole has a C-type cross section and the quadrupole and sextupole cross sections have 180 degrees and 120 degrees symmetries, respectively. The data statistics include the integrated main fields, multipole coefficients, magnetic and mechanical axes, and roll angles of the main fields. The average and rms values of the measured magnet data meet the storage ring requirements

  13. The Association between Primary Open-Angle Glaucoma and Blood Pressure: Two Aspects of Hypertension and Hypotension

    Directory of Open Access Journals (Sweden)

    Hye Jin Chung

    2015-01-01

    Full Text Available Glaucoma is the second leading cause of blindness worldwide. Although the mechanism of the development of primary open-angle glaucoma (POAG is not fully understood, elevated intraocular pressure (IOP is considered the most important risk factor. Several vascular factors have also been identified as risk factors and can lead to hypoperfusion of the optic nerve head and thus may play an important role in the pathogenesis and progression of POAG. The results of the present study suggest that both high and low blood pressure (BP are associated with an increased risk of POAG based on a comprehensive literature review. Elevated BP is associated with elevated IOP, leading to increased risk of glaucoma, but excessive BP lowering in glaucoma patients may cause a drop in ocular perfusion pressure (OPP and subsequent ischemic injury. The relationship between IOP, OPP, and BP suggests that the relationship between BP and glaucoma progression is U-shaped.

  14. Evaluation of anterior chamber angle under dark and light conditions in angle closure glaucoma: An anterior segment OCT study.

    Science.gov (United States)

    Masoodi, Habibeh; Jafarzadehpur, Ebrahim; Esmaeili, Alireza; Abolbashari, Fereshteh; Ahmadi Hosseini, Seyed Mahdi

    2014-08-01

    To evaluate changes of nasal and temporal anterior chamber angle (ACA) in subjects with angle closure glaucoma using Spectralis AS-OCT (SAS-OCT) under dark and light conditions. Based on dark-room gonioscopy, 24 subjects with open angles and 86 with narrow angles participated in this study. The nasal and temporal angle opening distance at 500 μm anterior to the scleral spur (AOD500), nasal and temporal ACA were measured using SAS-OCT in light and dark conditions. In 2 groups, ACA and AOD500 in nasal and temporal quadrants were significantly greater in light compared to dark (all with p=0.000). The AOD500 and ACA were significantly higher in nasal than temporal in measured conditions for 2 groups except the ACA and AOD500 of normal group measured in light. The difference between nasal and temporal in dark (29.07 ± 65.71 μm for AOD500 and 5.7 ± 4.07° for ACA) was greater than light (24.86 ± 79.85 μm for AOD500 and 2.09 ± 7.21° for ACA) condition. But the difference was only significant for ACA (p=0.000). The correlation analysis showed a negative correlation between AOD500 and pupil diameter in temporal and nasal quadrants (both with p=0.000). While temporal AOD500 difference correlated with spherical equivalent, temporal and asal gonioscopy, nasal AOD correlated with IOP, temporal and nasal gonioscopy. Clinically important changes in ACA structure could be detected with SAS-OCT in nasal and temporal quadrants under different illumination intensity. The results could help in improvement of examination condition for better and more accurate assessment of individuals with angle closure glaucoma. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  15. Modeling the Effects of Mirror Misalignment in a Ring Imaging Cherenkov Detector

    Science.gov (United States)

    Hitchcock, Tawanda; Harton, Austin; Garcia, Edmundo

    2012-03-01

    The Very High Momentum Particle Identification Detector (VHMPID) has been proposed for the ALICE experiment at the Large Hadron Collider (LHC). This detector upgrade is considered necessary to study jet-matter interaction at high energies. The VHMPID identifies charged hadrons in the 5 GeV/c to 25 GeV/c momentum range. The Cherenkov photons emitted in the VHMPID radiator are collected by spherical mirrors and focused onto a photo-detector plane forming a ring image. The radius of this ring is related to the Cherenkov angle, this information coupled with the particle momentum allows the particle identification. A major issue in the RICH detector is that environmental conditions can cause movements in mirror position. In addition, chromatic dispersion causes the refractive index to shift, altering the Cherenkov angle. We are modeling a twelve mirror RICH detector taking into account the effects of mirror misalignment and chromatic dispersion using a commercial optical software package. This will include quantifying the effects of both rotational and translational mirror misalignment for the initial assembly of the module and later on particle identification.

  16. CONSTRAINING THE LIFETIME AND OPENING ANGLE OF QUASARS USING FLUORESCENT Ly α EMISSION: THE CASE OF Q0420–388

    International Nuclear Information System (INIS)

    Borisova, Elena; Lilly, Simon J.; Cantalupo, Sebastiano; Prochaska, J. Xavier; Rakic, Olivera; Worseck, Gabor

    2016-01-01

    A toy model is developed to understand how the spatial distribution of fluorescent emitters in the vicinity of bright quasars could be affected by the geometry of the quasar bi-conical radiation field and by its lifetime. The model is then applied to the distribution of high-equivalent-width Ly α emitters (with rest-frame equivalent widths above 100 Å, threshold used in, e.g., Trainor and Steidel) identified in a deep narrow-band 36 × 36 arcmin 2 image centered on the luminous quasar Q0420–388. These emitters are found near the edge of the field and show some evidence of an azimuthal asymmetry on the sky of the type expected if the quasar is radiating in a bipolar cone. If these sources are being fluorescently illuminated by the quasar, the two most distant objects require a lifetime of at least 15 Myr for an opening angle of 60° or more, increasing to more than 40 Myr if the opening angle is reduced to a minimum of 30°. However, some other expected signatures of boosted fluorescence are not seen at the current survey limits, e.g., a fall off in Ly α brightness, or equivalent width, with distance. Furthermore, to have most of the Ly α emission of the two distant sources to be fluorescently boosted would require the quasar to have been significantly brighter in the past. This suggests that these particular sources may not be fluorescent, invalidating the above lifetime constraints. This would cast doubt on the use of this relatively low equivalent width threshold and thus also on the lifetime analysis in Trainor and Steidel.

  17. CONSTRAINING THE LIFETIME AND OPENING ANGLE OF QUASARS USING FLUORESCENT Ly α EMISSION: THE CASE OF Q0420–388

    Energy Technology Data Exchange (ETDEWEB)

    Borisova, Elena; Lilly, Simon J.; Cantalupo, Sebastiano [Institute for Astronomy, ETH Zurich, Zurich, CH-8093 (Switzerland); Prochaska, J. Xavier [UCO/Lick Observatory, UC Santa Cruz, Santa Cruz, CA 95064 (United States); Rakic, Olivera; Worseck, Gabor, E-mail: borisova@phys.ethz.ch [Max-Planck-Institut für Astronomie, Heidelberg, D-69117 (Germany)

    2016-10-20

    A toy model is developed to understand how the spatial distribution of fluorescent emitters in the vicinity of bright quasars could be affected by the geometry of the quasar bi-conical radiation field and by its lifetime. The model is then applied to the distribution of high-equivalent-width Ly α emitters (with rest-frame equivalent widths above 100 Å, threshold used in, e.g., Trainor and Steidel) identified in a deep narrow-band 36 × 36 arcmin{sup 2} image centered on the luminous quasar Q0420–388. These emitters are found near the edge of the field and show some evidence of an azimuthal asymmetry on the sky of the type expected if the quasar is radiating in a bipolar cone. If these sources are being fluorescently illuminated by the quasar, the two most distant objects require a lifetime of at least 15 Myr for an opening angle of 60° or more, increasing to more than 40 Myr if the opening angle is reduced to a minimum of 30°. However, some other expected signatures of boosted fluorescence are not seen at the current survey limits, e.g., a fall off in Ly α brightness, or equivalent width, with distance. Furthermore, to have most of the Ly α emission of the two distant sources to be fluorescently boosted would require the quasar to have been significantly brighter in the past. This suggests that these particular sources may not be fluorescent, invalidating the above lifetime constraints. This would cast doubt on the use of this relatively low equivalent width threshold and thus also on the lifetime analysis in Trainor and Steidel.

  18. Propellers in Saturn's rings

    Science.gov (United States)

    Sremcevic, M.; Stewart, G. R.; Albers, N.; Esposito, L. W.

    2013-12-01

    Theoretical studies and simulations have demonstrated the effects caused by objects embedded in planetary rings. Even if the objects are too small to be directly observed, each creates a much larger gravitational imprint on the surrounding ring material. These strongly depend on the mass of the object and range from "S" like propeller-shaped structures for about 100m-sized icy bodies to the opening of circumferential gaps as in the case of the embedded moons Pan and Daphnis and their corresponding Encke and Keeler Gaps. Since the beginning of the Cassini mission many of these smaller objects (~data from Cassini Ultraviolet Imaging Spectrograph (UVIS) and Imaging Science Subsystem (ISS) experiments. We show evidence that B ring seems to harbor two distinct populations of propellers: "big" propellers covering tens of degrees in azimuth situated in the densest part of B ring, and "small" propellers in less dense inner B ring that are similar in size and shape to known A ring propellers. The population of "big" propellers is exemplified with a single object which is observed for 5 years of Cassini data. The object is seen as a very elongated bright stripe (40 degrees wide) in unlit Cassini images, and dark stripe in lit geometries. In total we report observing the feature in images at 18 different epochs between 2005 and 2010. In UVIS occultations we observe this feature as an optical depth depletion in 14 out of 93 occultation cuts at corrotating longitudes compatible with imaging data. Combining the available Cassini data we infer that the object is a partial gap located at r=112,921km embedded in the high optical depth region of the B ring. The gap moves at Kepler speed appropriate for its radial location. Radial offsets of the gap locations in UVIS occultations are consistent with an asymmetric propeller shape. The asymmetry of the observed shape is most likely a consequence of the strong surface mass density gradient, as the feature is located at an edge between

  19. High prevalence of narrow angles among Chinese-American glaucoma and glaucoma suspect patients.

    Science.gov (United States)

    Seider, Michael I; Pekmezci, Melike; Han, Ying; Sandhu, Simi; Kwok, Shiu Y; Lee, Roland Y; Lin, Shan C

    2009-01-01

    To evaluate the prevalence of gonioscopically narrow angles in a Chinese-American population with glaucoma or glaucoma suspicion. Charts from all Chinese-American patients seen in a comprehensive ophthalmology clinic in the Chinatown district of San Francisco in 2002 were reviewed. One eye from each patient with glaucoma or glaucoma suspicion that met inclusion criteria was included (n=108). Data were collected for sex, age, race (self-declared), refraction (spherical equivalent), intraocular pressure, gonioscopy, and vertical cup-to-disk ratio. Sixty percent (n=65) of Chinese-American eyes with glaucoma or glaucoma suspicion had gonioscopically narrow angles (Shaffer grade or = 0.071). In a multivariate model including age, sex, and refraction as predictors of angle grade (open or narrow), only age was a significant predictor of angle grade (P=0.004). A large proportion of Chinese-Americans in our study population with glaucoma or glaucoma suspicion had gonioscopically narrow angles. In multivariate analysis, patients with narrow angles were older than those with open angles but did not differ from them in terms of sex or refraction. Continued evaluation of angle closure glaucoma risk among Chinese-Americans is needed.

  20. Spectrophotometric study of Saturn's main rings by means of Monte Carlo ray-tracing and Hapke's theory

    Science.gov (United States)

    Ciarniello, Mauro; Filacchione, Gianrico; D'Aversa, Emiliano; Cuzzi, Jeffrey N.; Capaccioni, Fabrizio; Hedman, Matthew M.; Dalle Ore, Cristina M.; Nicholson, Philip D.; Clark, Roger Nelson; Brown, Robert H.; Cerroni, Priscilla; Spilker, Linda

    2017-10-01

    This work is devoted to the investigation of the spectrophotometric properties of Saturn's rings from Cassini-VIMS (Visible and Infrared Mapping Spectrometer) observations. The dataset used for this analysis is represented by ten radial spectrograms of the rings which have been derived in Filacchione et al. (2014) by radial mosaics produced by VIMS. Spectrograms report the measured radiance factor of the main Saturn's rings as a function of both radial distance (from 73.500 to 141.375 km) and wavelength (0.35-5.1 µm) for different observation geometries (phase angle ranging in the 1.9°-132.2° interval). We take advantage of a Monte Carlo ray-tracing routine to characterize the photometric behavior of the rings at each wavelength and derive the spectral Bond albedo of rings particles. This quantity is used to infer the composition of the regolith covering rings particles by applying Hapke's theory. Four different regions, characterized by different optical depths, and respectively located in the C ring, inner B ring, mid B ring and A ring, have been investigated. Results from spectral modeling indicate that rings spectrum can be described by water ice with minimal inclusion of organic materials (tholin, exogenous material, which is more effective in the less dense regions of the rings because of their lower content of pure water ice.

  1. ULTRAVIOLET TRANSITIONS IN EUROPIUM STUDIED WITH A FREQUENCY-DOUBLED CW RING DYE-LASER

    NARCIS (Netherlands)

    Eliel, E.R.; Hogervorst, W.; van Leeuwen, K.A.H.; Post, B.H.

    1981-01-01

    High resolution laser spectroscopy has been applied to the study of three ultraviolet transitions in Europium at λ = 294.8, 295.1 and 295.8 nm. The tunable narrowband UV has been generated by intracavity frequency doubling in a cw ring dye laser using a temperate tuned, Brewster angled ADA crystal.

  2. ASSOCIATIVE RINGS SOLVED AS LIE RINGS

    Directory of Open Access Journals (Sweden)

    M. B. Smirnov

    2011-01-01

    Full Text Available The paper has proved that an associative ring which is solvable of a n- class as a Lie ring has a nilpotent ideal of the nilpotent class not more than 3×10n–2  and a corresponding quotient ring satisfies an identity [[x1, x2, [x3, x4

  3. Local beam angle optimization with linear programming and gradient search

    International Nuclear Information System (INIS)

    Craft, David

    2007-01-01

    The optimization of beam angles in IMRT planning is still an open problem, with literature focusing on heuristic strategies and exhaustive searches on discrete angle grids. We show how a beam angle set can be locally refined in a continuous manner using gradient-based optimization in the beam angle space. The gradient is derived using linear programming duality theory. Applying this local search to 100 random initial angle sets of a phantom pancreatic case demonstrates the method, and highlights the many-local-minima aspect of the BAO problem. Due to this function structure, we recommend a search strategy of a thorough global search followed by local refinement at promising beam angle sets. Extensions to nonlinear IMRT formulations are discussed. (note)

  4. Competitive and Cooperative Torquoselectivity in the thermal ring ...

    Indian Academy of Sciences (India)

    All the stationary points and TSs were optimized at. B3LYP23/6-31G (d) level using Gaussian 98 software.24. The stationary geometries of reactants and products were characterized with real frequencies and TSs have one imaginary frequency with animation corresponding to conrotatory ring opening. Thermochemical and ...

  5. Prevalence of primary open-angle glaucoma in an urban south Indian population and comparison with a rural population. The Chennai Glaucoma Study.

    Science.gov (United States)

    Vijaya, Lingam; George, Ronnie; Baskaran, M; Arvind, Hemamalini; Raju, Prema; Ramesh, S Ve; Kumaramanickavel, Govindasamy; McCarty, Catherine

    2008-04-01

    To estimate the prevalence and risk factors of primary open-angle glaucoma (POAG) in an urban population and compare the same with that of our published rural population data in southern India. Population-based cross-sectional study. Four thousand eight hundred subjects 40 years or older were selected using a multistage random cluster sampling procedure in Chennai city. Three thousand eight hundred fifty (80.2%) subjects underwent a complete ophthalmic examination, including applanation tonometry, gonioscopy, pachymetry, optic disc photography, and automated perimetry. Glaucoma was diagnosed using the International Society of Geographical and Epidemiological Ophthalmology Classification. The distribution of intraocular pressure (IOP) and vertical cup-to-disc ratio (VCDR) was obtained from the right eye of the 2532 subjects with normal suprathreshold visual fields. Mean IOP was 16.17+/-3.74 mmHg (97.5th and 99.5th percentiles, 24 mmHg and 30 mmHg). The mean VCDR was 0.43+/-0.17 (97.5th and 99.5th percentiles, 0.7 and 0.8). One hundred thirty-five (64 men, 71 women) subjects had POAG (3.51%; 95% confidence interval [CI], 3.04-4.0). Primary open-angle glaucoma subjects (58.4+/-11.3 years) were older (P or =40-year-old south Indian urban population was 3.51%, higher than that of the rural population. The prevalence increased with age, and >90% were not aware of the disease.

  6. Progressive Macula Vessel Density Loss in Primary Open-Angle Glaucoma: A Longitudinal Study.

    Science.gov (United States)

    Shoji, Takuhei; Zangwill, Linda M; Akagi, Tadamichi; Saunders, Luke J; Yarmohammadi, Adeleh; Manalastas, Patricia Isabel C; Penteado, Rafaella C; Weinreb, Robert N

    2017-10-01

    To characterize the rate of macula vessel density loss in primary open-angle glaucoma (POAG), glaucoma-suspect, and healthy eyes. Longitudinal, observational cohort from the Diagnostic Innovations in Glaucoma Study. One hundred eyes (32 POAG, 30 glaucoma-suspect, and 38 healthy) followed for at least 1 year with optical coherence tomography angiography (OCT-A) imaging on at least 2 visits were included. Vessel density was calculated in the macula superficial layer. The rate of change was compared across diagnostic groups using a multivariate linear mixed-effects model. Baseline macula vessel density was highest in healthy eyes, followed by glaucoma-suspect and POAG eyes (P macula whole en face vessel density was significantly faster in glaucoma eyes (-2.23%/y) than in glaucoma-suspect (0.87%/y, P = .001) or healthy eyes (0.29%/y, P = .004). Conversely, the rate of change in ganglion cell complex (GCC) thickness was not significantly different from zero in any diagnostic group, and no significant differences in the rate of GCC change among diagnostic groups were found. With a mean follow-up of less than 14 months, eyes with POAG had significantly faster loss of macula vessel density than either glaucoma-suspect or healthy eyes. Serial OCT-A measurements also detected glaucomatous change in macula vessel density in eyes without evidence of change in GCC thickness. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. High prevalence of anxiety and depression in patients with primary open-angle glaucoma.

    Science.gov (United States)

    Mabuchi, Fumihiko; Yoshimura, Kimio; Kashiwagi, Kenji; Shioe, Kunihiko; Yamagata, Zentaro; Kanba, Shigenobu; Iijima, Hiroyuki; Tsukahara, Shigeo

    2008-01-01

    To assess anxiety and depression in patients with primary open-angle glaucoma (POAG). Multicenter prospective case-control study. Two hundred thirty patients with POAG and 230 sex-matched and age-matched reference subjects with no chronic ocular conditions except cataracts. Anxiety and depression were evaluated using Hospital Anxiety and Depression Scale (HADS) questionnaire, which consists of 2 subscales with ranges of 0 to 21, representing anxiety (HADS-A) and depression (HADS-D). The prevalence of POAG patients with anxiety (a score of more than 10 on the HADS-A) or depression (a score of more than 10 on the HADS-D) was compared with that in the reference subjects. The prevalence of patients with depression was compared between the POAG patients with and without current beta-blocker eye drops. The prevalence (13.0%) of POAG patients with anxiety was significantly higher (P=0.030) than in the reference subjects (7.0%). The prevalence (10.9%) of POAG patients with depression was significantly higher (P=0.026) than in the reference subjects (5.2%). Between the POAG patients with and without beta-blocker eye-drops, no significant difference (P=0.93) in the prevalence of depression was noted. POAG was related to anxiety and depression. No significant relationship between the use of beta-blocker eye-drops and depression was noted.

  8. Structural brain alterations in primary open angle glaucoma: a 3T MRI study

    Science.gov (United States)

    Wang, Jieqiong; Li, Ting; Sabel, Bernhard A.; Chen, Zhiqiang; Wen, Hongwei; Li, Jianhong; Xie, Xiaobin; Yang, Diya; Chen, Weiwei; Wang, Ningli; Xian, Junfang; He, Huiguang

    2016-01-01

    Glaucoma is not only an eye disease but is also associated with degeneration of brain structures. We now investigated the pattern of visual and non-visual brain structural changes in 25 primary open angle glaucoma (POAG) patients and 25 age-gender-matched normal controls using T1-weighted imaging. MRI images were subjected to volume-based analysis (VBA) and surface-based analysis (SBA) in the whole brain as well as ROI-based analysis of the lateral geniculate nucleus (LGN), visual cortex (V1/2), amygdala and hippocampus. While VBA showed no significant differences in the gray matter volumes of patients, SBA revealed significantly reduced cortical thickness in the right frontal pole and ROI-based analysis volume shrinkage in LGN bilaterally, right V1 and left amygdala. Structural abnormalities were correlated with clinical parameters in a subset of the patients revealing that the left LGN volume was negatively correlated with bilateral cup-to-disk ratio (CDR), the right LGN volume was positively correlated with the mean deviation of the right visual hemifield, and the right V1 cortical thickness was negatively correlated with the right CDR in glaucoma. These results demonstrate that POAG affects both vision-related structures and non-visual cortical regions. Moreover, alterations of the brain visual structures reflect the clinical severity of glaucoma. PMID:26743811

  9. In Situ Generated Ruthenium-Arene Catalyst for Photoactivated Ring-Opening Metathesis Polymerization through Photolatent N-Heterocyclic Carbene Ligand.

    Science.gov (United States)

    Pinaud, Julien; Trinh, Thi Kim Hoang; Sauvanier, David; Placet, Emeline; Songsee, Sriprapai; Lacroix-Desmazes, Patrick; Becht, Jean-Michel; Tarablsi, Bassam; Lalevée, Jacques; Pichavant, Loïc; Héroguez, Valérie; Chemtob, Abraham

    2018-01-09

    1,3-Bis(mesityl)imidazolium tetraphenylborate (IMesH + BPh 4 - ) can be synthesized in one step by anion metathesis between the corresponding imidazolium chloride and sodium tetraphenylborate. In the presence of 2-isopropylthioxanthone (sensitizer), an IMes N-heterocyclic carbene (NHC) ligand can be photogenerated under irradiation at 365 nm through coupled electron/proton transfer reactions. By combining this tandem NHC photogenerator system with metathesis inactive [RuCl 2 (p-cymene)] 2 precatalyst, the highly active RuCl 2 (p-cymene)(IMes) complex can be formed in situ, enabling a complete ring-opening metathesis polymerization (ROMP) of norbornene in the matter of minutes at room temperature. To the best of our knowledge, this is the first example of a photogenerated NHC. Its exploitation in photoROMP has resulted in a simplified process compared to current photocatalysts, because only stable commercial or easily synthesized reagents are required. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Joining by plating: optimization of occluded angle

    International Nuclear Information System (INIS)

    Dini, J.W.; Johnson, H.R.; Kan, Y.R.

    1978-11-01

    An empirical method has been developed for predicting the minimum angle required for maximum joint strength for materials joined by plating. This is done through a proposed power law failure function, whose coefficients are taken from ring shear and conical head tensile data for plating/substrate combinations and whose exponent is determined from one set of plated-joint data. Experimental results are presented for Al-Ni-Al (7075-T6) and AM363-Ni-AM363 joints, and the failure function is used to predict joint strengths for Al-Ni-Al (2024-T6), UTi-Ni-UTi, and Be-Ti-Be

  11. Anterior chamber angle assessment using gonioscopy and ultrasound biomicroscopy.

    Science.gov (United States)

    Narayanaswamy, Arun; Vijaya, Lingam; Shantha, B; Baskaran, Mani; Sathidevi, A V; Baluswamy, Sukumar

    2004-01-01

    Comparison of anterior chamber angle measurements using ultrasound biomicroscopy (UBM) and gonioscopy. Five hundred subjects were evaluated for grading of angle width by the Shaffer method. UBM was done in the same group to document angle width, angle opening distance (AOD 500), and anterior chamber depth. Biometric parameters were documented in all subjects. UBM and gonioscopic findings were compared. A study was conducted in 282 men and 218 women with a mean age of 57.32 +/- 12.48 years. Gonioscopic grading was used to segregate occludable (slit-like, grades 1 and 2) from nonoccludable (grades 3 and 4) angles. Subjective assessment by gonioscopy resulted in an overestimation of angle width within the occludable group when compared with values obtained by UBM. This did not affect the segregation of occludable versus nonoccludable angles by gonioscopy. Biometric parameters in eyes with occludable angles were significantly lower in comparison with eyes with nonoccludable angles, except for lens thickness. AOD 500 correlated well with angle width. We concluded that clinical segregation into occludable and nonoccludable angles by an experienced observer using gonioscopy is fairly accurate. However, UBM is required for objective quantification of angles, and AOD 500 can be a reliable and standard parameter to grade angle width.

  12. Determination of the Contact Angle Based on the Casimir Effect

    Science.gov (United States)

    Mazuruk, Konstantin; Volz, Martin P.

    2015-01-01

    On a macroscopic scale, a nonreactive liquid partially covering a homogeneous solid surface will intersect the solid at an angle called the contact angle. For molten metals and semiconductors, the contact angle is materially dependent upon both the solid and liquid and typical values fall in the range 80-170 deg, depending on the crucible material. On a microscopic scale, there does not exist a precise and sharp contact angle but rather the liquid and solid surfaces merge smoothly and continuously. Consider the example of the so called detached Bridgman crystal growth process. In this technique, a small gap is formed between the growing crystal and the crucible. At the crystal/melt interface, a meniscus ring is formed. Its width can be in the range of a few micrometers, approaching a microscopic scale. It then becomes questionable to describe the shape of this meniscus by the contact angle. A more advanced treatment of the interface is needed and here we propose such a refined model. The interaction of the liquid surface with the solid can be calculated by considering two forces: a short-range repulsive force and a longer range (up to a few micrometers) Casimir or van der Waals force.

  13. Ring-shaped Wigner crystals of trapped ions at the micronscale

    Science.gov (United States)

    Li, Haokun; Urban, Erik; Noel, Crystal; Chuang, Alexander; Xia, Yang; Hemmerling, Borge; Wang, Yuan; Zhang, Xiang; Haeffner, Hartmut

    Trapped ion crystals are ideal platforms to study many-body physics and quantum information processing, with both the internal electronic states and external motional degree-of-freedoms controllable at the single quantum level. In contrast to conventional, finite, linear chains of ions, a ring topology exhibiting periodic boundary conditions and rotational symmetry opens up a new directions to diverse topics. However, previous implementations of ion rings result in small aspect ratios (electrode distance to ring diameter, making the rotational symmetry of the ion crystals prone to stray electric fields from imperfections of the trap electrodes, particularly evident at low temperatures. Here, using a new trap design with a 60-fold improvement of this aspect ratio, we demonstrate crystallization of 40Ca+ ions in a ring with rotational energy barriers comparable to the thermal energy of Doppler laser cooled ion crystals. When further reducing the rotational energy barriers, we observe delocalization of the ion rings. With this result, we enter a regime where quantum topological effects can be studied and novel quantum computation and simulation experiments can be implemented.

  14. Conference on Commutative rings, integer-valued polynomials and polynomial functions

    CERN Document Server

    Frisch, Sophie; Glaz, Sarah; Commutative Algebra : Recent Advances in Commutative Rings, Integer-Valued Polynomials, and Polynomial Functions

    2014-01-01

    This volume presents a multi-dimensional collection of articles highlighting recent developments in commutative algebra. It also includes an extensive bibliography and lists a substantial number of open problems that point to future directions of research in the represented subfields. The contributions cover areas in commutative algebra that have flourished in the last few decades and are not yet well represented in book form. Highlighted topics and research methods include Noetherian and non- Noetherian ring theory as well as integer-valued polynomials and functions. Specific topics include: ·    Homological dimensions of Prüfer-like rings ·    Quasi complete rings ·    Total graphs of rings ·    Properties of prime ideals over various rings ·    Bases for integer-valued polynomials ·    Boolean subrings ·    The portable property of domains ·    Probabilistic topics in Intn(D) ·    Closure operations in Zariski-Riemann spaces of valuation domains ·    Stability of do...

  15. An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents

    Directory of Open Access Journals (Sweden)

    Jing Lin

    2016-02-01

    Full Text Available Whereas buckling can cause type III endoleaks, long-term twisting of a stent-graft was investigated here as a mechanism leading to type V endoleak or endotension. Two experimental device designs supported with Z-stents having strut angles of 35° or 45° were compared to a ringed control under accelerated twisting. Damage to each device was assessed and compared after different durations of twisting, with focus on damage that may allow leakage. Stent-grafts with 35° Z-stents had the most severe distortion and damage to the graft fabric. The 45° Z-stents caused less fabric damage. However, consistent stretching was still seen around the holes for sutures, which attach the stents to the graft fabric. Larger holes may become channels for fluid percolation through the wall. The ringed stent-graft had the least damage observed. Stent apexes with sharp angles appear to be responsible for major damage to the fabrics. Device manufacturers should consider stent apex angle when designing stent-grafts, and ensure their devices are resistant to twisting.

  16. An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents.

    Science.gov (United States)

    Lin, Jing; Guidoin, Robert; Du, Jia; Wang, Lu; Douglas, Graeham; Zhu, Danjie; Nutley, Mark; Perron, Lygia; Zhang, Ze; Douville, Yvan

    2016-02-16

    Whereas buckling can cause type III endoleaks, long-term twisting of a stent-graft was investigated here as a mechanism leading to type V endoleak or endotension. Two experimental device designs supported with Z-stents having strut angles of 35° or 45° were compared to a ringed control under accelerated twisting. Damage to each device was assessed and compared after different durations of twisting, with focus on damage that may allow leakage. Stent-grafts with 35° Z-stents had the most severe distortion and damage to the graft fabric. The 45° Z-stents caused less fabric damage. However, consistent stretching was still seen around the holes for sutures, which attach the stents to the graft fabric. Larger holes may become channels for fluid percolation through the wall. The ringed stent-graft had the least damage observed. Stent apexes with sharp angles appear to be responsible for major damage to the fabrics. Device manufacturers should consider stent apex angle when designing stent-grafts, and ensure their devices are resistant to twisting.

  17. Efficacy and safety of prostaglandin analogues in patients with predominantly primary open-angle glaucoma or ocular hypertension: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Oghenowede Eyawo

    2009-07-01

    Full Text Available Oghenowede Eyawo1, Jean Nachega2,3, Pierre Lefebvre4, David Meyer5, Beth Rachlis6, Chia-Wen Lee7, Steven Kelly7, Edward Mills81Faculty of Health Sciences, Simon Fraser University, Vancouver, Canada; 2Division of Clinical Pharmacology and Medicine, University of Cape Town, Cape Town, South Africa; 3Johns Hopkins Bloomberg School of Public Health, Baltimore, USA; 4Department of Ophthalmology, Moorfields Eye Hospital, London, United Kingdom; 5Department of Ophthalmology, Stellenbosch University, Cape Town, South Africa; 6Department of Public Health, University of Toronto, Toronto, Canada; 7Outcome Research and Evidence Based Medicine, Pfizer Ltd UK. Tadworth, UK; 8Department of Clinical Epidemiology and Biostatistics, McMaster University, Hamilton, CanadaBackground: First-line therapy for primary open-angle glaucoma and ocular hypertension generally involves prostaglandin analogue therapy. The relative efficacy of differing prostaglandin therapy is disputed.Methods: A meta-analysis was conducted of head-to-head randomized trials of prostaglandin therapies. We included randomized trials assessing head-to-head evaluations of prostaglandin analogues travoprost, latanoprost and bimatoprost in patients with predominantly primary open-angle glaucoma or ocular hypertension. Findings were interpreted in light of equivalence margins.Results: Our search identified 16 eligible trials, of which 15 were included in the meta-analysis. Trials were, in general, poorly reported. We pooled 9 trials assessing IOP-lowering effects of travoprost vs latanoprost (total n = 1098, weighted mean difference [WMD], –0.24 mmHg, 95% CI, –0.87 to 0.38, P = 0.45, I2 = 56%, 95% CI, 0 to 0.77, heterogeneity P = 0.01. Eight trials assessed travoprost vs bimatoprost (total n = 714, WMD, 0.88 mmHg, 95% CI, 0.13 to 1.63, P = 0.02, I2 = 56%, 95% CI, 0% to 78%, heterogeneity P = 0.02. And 8 trials assessed latanoprost vs bimatoprost (total n = 943, WMD, 0.73 mmHg, 95% CI, 0.10 to 1

  18. The forward ring imaging Cherenkov detector of DELPHI

    International Nuclear Information System (INIS)

    Adam, W.; Albrecht, E.; Ambec, I.; Augustinus, A.; Barnoux, C.; Bostjancic, B.; Botner, O.; Budziak, A.P.; Caloba, L.P.; Carecchio, P.; Cavalli, P.; Ceelie, L.; Cereseto, R.; Cerutti, G.; Dahl-Jensen, E.; Dam, P.; Damgaard, G.; Koning, N. de; De la Vega, A.S.; Dimitriou, N.; Dulinski, W.; Eek, L.O.; Ekeloef, T.; Erikson, J.; Florek, A.; Florek, B.; Fontanelli, F.; Fontenille, A.; Galuszka, K.; Garcia, J.; Gracco, V.; Hallgren, A.; Hao, W.; Henkes, T.; Isenhower, D.; Johansson, H.; Karvelas, E.; Kindblom, P.; Koene, B.; Korporaal, A.; Kostarakis, P.; Lenzen, G.; Lindqvist, L.E.; Lorenz, P.; Loukas, D.; Lund-Jensen, B.; Maltezos, A.; Markou, A.; Mattsson, L.; Medbo, J.; Michalowski, J.; Montano, F.; Nielsen, B.S.; Ostler, J.M.; Pakonski, K.; Perdikis, C.; Polok, G.; Robohm, A.; Sajot, G.; Sannino, M.; Saragas, E.; Schyns, E.; Squarcia, S.; Stavropoulos, G.; Stodulski, M.; Stopa, Z.; Thadome, J.; Theodosiou, G.E.; Traspedini, L.; Turala, M.; Ullaland, O.; Waerm, A.; Werner, J.; Xyroutsikos, S.; Zavrtanik, M.; Zevgolatakos, E.

    1994-01-01

    The Forward Ring Imaging Cherenkov detector of the DELPHI experiment at LEP provides hadron identification at polar angles 15 6 F 14 and a volume of gaseous C 4 F 10 , in combination provide coverage of momenta up to 40 GeV/c. A single array of photosensitive Time Projection Chambers registers the impact points of ultraviolet photons from both radiators. The design of the detector and of its readout system is described. First results obtained with a partly installed detector are reported. (orig.)

  19. Mapping Ring Particle Cooling across Saturn's Rings with Cassini CIRS

    Science.gov (United States)

    Brooks, Shawn M.; Spilker, L. J.; Edgington, S. G.; Pilorz, S. H.; Deau, E.

    2010-10-01

    Previous studies have shown that the rings' thermal inertia, a measure of their response to changes in the thermal environment, varies from ring to ring. Thermal inertia can provide insight into the physical structure of Saturn's ring particles and their regoliths. Low thermal inertia and quick temperature responses are suggestive of ring particles that have more porous or fluffy regoliths or that are riddled with cracks. Solid, coherent particles can be expected to have higher thermal inertias (Ferrari et al. 2005). Cassini's Composite Infrared Spectrometer has recorded millions of spectra of Saturn's rings since its arrival at Saturn in 2004 (personal communication, M. Segura). CIRS records far infrared radiation between 10 and 600 cm-1 (16.7 and 1000 µm) at focal plane 1 (FP1), which has a field of view of 3.9 mrad. Thermal emission from Saturn's rings peaks in this wavelength range. FP1 spectra can be used to infer ring temperatures. By tracking how ring temperatures vary, we can determine the thermal inertia of the rings. In this work we focus on CIRS observations of the shadowed portion of Saturn's rings. The thermal budget of the rings is dominated by the solar radiation absorbed by its constituent particles. When ring particles enter Saturn's shadow this source of energy is abruptly cut off. As a result, ring particles cool as they traverse Saturn's shadow. From these shadow observations we can create cooling curves at specific locations across the rings. We will show that the rings' cooling curves and thus their thermal inertia vary not only from ring to ring, but by location within the individual rings. This research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under contract with NASA. Copyright 2010 California Institute of Technology. Government sponsorship acknowledged.

  20. One-Pot Parallel Synthesis of Lipid Library via Thiolactone Ring Opening and Screening for Gene Delivery.

    Science.gov (United States)

    Molla, Mijanur R; Böser, Alexander; Rana, Akshita; Schwarz, Karina; Levkin, Pavel A

    2018-04-18

    Efficient delivery of nucleic acids into cells is of great interest in the field of cell biology and gene therapy. Despite a lot of research, transfection efficiency and structural diversity of gene-delivery vectors are still limited. A better understanding of the structure-function relationship of gene delivery vectors is also essential for the design of novel and intelligent delivery vectors, efficient in "difficult-to-transfect" cells and in vivo clinical applications. Most of the existing strategies for the synthesis of gene-delivery vectors require multiple steps and lengthy procedures. Here, we demonstrate a facile, three-component one-pot synthesis of a combinatorial library of 288 structurally diverse lipid-like molecules termed "lipidoids" via a thiolactone ring opening reaction. This strategy introduces the possibility to synthesize lipidoids with hydrophobic tails containing both unsaturated bonds and reducible disulfide groups. The whole synthesis and purification are convenient, extremely fast, and can be accomplished within a few hours. Screening of the produced lipidoids using HEK293T cells without addition of helper lipids resulted in identification of highly stable liposomes demonstrating ∼95% transfection efficiency with low toxicity.

  1. Solvent micro-evaporation and concentration gradient synergistically induced crystallization of poly(L-lactide) and ring banded supra-structures with radial periodic variation of thickness

    DEFF Research Database (Denmark)

    Huang, Shaoyong; Li, Hongfei; Wen, Huiying

    2014-01-01

    The crystalline morphology and structure of poly(L-lactide) (PLLA) in a PLLA film-chloroform system were investigated by means of wide angle X-ray diffraction (WAXD), polarized optical microscopy (POM) and atomic force microscopy (AFM). Birefringent and nonbirefringent ring banded supra-structure......The crystalline morphology and structure of poly(L-lactide) (PLLA) in a PLLA film-chloroform system were investigated by means of wide angle X-ray diffraction (WAXD), polarized optical microscopy (POM) and atomic force microscopy (AFM). Birefringent and nonbirefringent ring banded supra......-structures with radial periodic variation of thickness were obtained, which were induced by micro-evaporation of solvents and concentration gradient of PLLA. The ring banded morphologies consisted of multilayer lamellar crystals, which is a manifestation of alternating ridge and valley bands of periodic variation...

  2. MR imaging findings of ring apophyseal fractures in lumbar vertebrae

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yong Soo; Kwon, Soon Tae; Song, Chang Joon; Lee, Young Hwan; Kim, Hyoung Seob; Lee, Hwan Do; Cho, June Sik; Ahn, Jae Sung; Lee, June Kyu [Chungnam National Univ. College of Medicine, Taejon (Korea, Republic of)

    1997-07-01

    To assess the location and associated findings of fractures of the posterior lumbar vertebral ring apophysis as seen on MRI We retrospectively evaluated MR findings in 77 patients (86 lesions) with lumbar apophyseal ring fractures. Their age ranged from ten to 67 (mean 33-1) years. To confirm the presence of verterbral ring fractures, CT was performed in 29 patients (31 lesions) within two weeks of MR imaging. Open laminectomy was performed in ten patients, percutaneous automated nucleotomy in three, and LASER operation in four. The most common location of fractures was the superior margin of L5 (36 lesions 41.9%), next was superior margin of S1 (21 lesions, 24.4%). On CT, a bony fragment was seen in 28 patients (30 lesions); the positive predictive value of MR was 99.7%. Multiple lesions were seen in nine patients. Associated disc herniation and bulging were noted in 64 (74.4%) and 15 lesions (17.4%), respectively, and a high signal intensity rim aound the bony fragment on T1 weighted image was noted in 33 (38.4%). Other associated findings were spondylolysis in eight patients, retrolisthesis in five, and spondylolisthesis in three. Operative outcomes were variable. The results of open laminectomy were better than those of percutaneous automated laminectomy or LASER operation. In patients with lumbar apophyseal ring fractures, their exact location and associated findings could be evalvated by MRI, which was therefore useful in the planning of appropriate surgery.

  3. MR imaging findings of ring apophyseal fractures in lumbar vertebrae

    International Nuclear Information System (INIS)

    Kang, Yong Soo; Kwon, Soon Tae; Song, Chang Joon; Lee, Young Hwan; Kim, Hyoung Seob; Lee, Hwan Do; Cho, June Sik; Ahn, Jae Sung; Lee, June Kyu

    1997-01-01

    To assess the location and associated findings of fractures of the posterior lumbar vertebral ring apophysis as seen on MRI We retrospectively evaluated MR findings in 77 patients (86 lesions) with lumbar apophyseal ring fractures. Their age ranged from ten to 67 (mean 33-1) years. To confirm the presence of verterbral ring fractures, CT was performed in 29 patients (31 lesions) within two weeks of MR imaging. Open laminectomy was performed in ten patients, percutaneous automated nucleotomy in three, and LASER operation in four. The most common location of fractures was the superior margin of L5 (36 lesions 41.9%), next was superior margin of S1 (21 lesions, 24.4%). On CT, a bony fragment was seen in 28 patients (30 lesions); the positive predictive value of MR was 99.7%. Multiple lesions were seen in nine patients. Associated disc herniation and bulging were noted in 64 (74.4%) and 15 lesions (17.4%), respectively, and a high signal intensity rim aound the bony fragment on T1 weighted image was noted in 33 (38.4%). Other associated findings were spondylolysis in eight patients, retrolisthesis in five, and spondylolisthesis in three. Operative outcomes were variable. The results of open laminectomy were better than those of percutaneous automated laminectomy or LASER operation. In patients with lumbar apophyseal ring fractures, their exact location and associated findings could be evalvated by MRI, which was therefore useful in the planning of appropriate surgery

  4. Angle closure glaucoma in congenital ectropion uvea.

    Science.gov (United States)

    Wang, Grace M; Thuente, Daniel; Bohnsack, Brenda L

    2018-06-01

    Congenital ectropion uvea is a rare anomaly, which is associated with open, but dysplastic iridocorneal angles that cause childhood glaucoma. Herein, we present 3 cases of angle-closure glaucoma in children with congenital ectropion uvea. Three children were initially diagnosed with unilateral glaucoma secondary to congenital ectropion uvea at 7, 8 and 13 years of age. The three cases showed 360° of ectropion uvea and iris stromal atrophy in the affected eye. In one case, we have photographic documentation of progression to complete angle closure, which necessitated placement of a glaucoma drainage device 3 years after combined trabeculotomy and trabeculectomy. The 2 other cases, which presented as complete angle closure, also underwent glaucoma drainage device implantation. All three cases had early glaucoma drainage device encapsulation (within 4 months) and required additional surgery (cycloablation or trabeculectomy). Congenital ectropion uvea can be associated with angle-closure glaucoma, and placement of glaucoma drainage devices in all 3 of our cases showed early failure due to plate encapsulation. Glaucoma in congenital ectropion uvea requires attention to angle configuration and often requires multiple surgeries to obtain intraocular pressure control.

  5. Angle closure glaucoma in congenital ectropion uvea

    Directory of Open Access Journals (Sweden)

    Grace M. Wang

    2018-06-01

    Full Text Available Purpose: Congenital ectropion uvea is a rare anomaly, which is associated with open, but dysplastic iridocorneal angles that cause childhood glaucoma. Herein, we present 3 cases of angle-closure glaucoma in children with congenital ectropion uvea. Observations: Three children were initially diagnosed with unilateral glaucoma secondary to congenital ectropion uvea at 7, 8 and 13 years of age. The three cases showed 360° of ectropion uvea and iris stromal atrophy in the affected eye. In one case, we have photographic documentation of progression to complete angle closure, which necessitated placement of a glaucoma drainage device 3 years after combined trabeculotomy and trabeculectomy. The 2 other cases, which presented as complete angle closure, also underwent glaucoma drainage device implantation. All three cases had early glaucoma drainage device encapsulation (within 4 months and required additional surgery (cycloablation or trabeculectomy. Conclusions and importance: Congenital ectropion uvea can be associated with angle-closure glaucoma, and placement of glaucoma drainage devices in all 3 of our cases showed early failure due to plate encapsulation. Glaucoma in congenital ectropion uvea requires attention to angle configuration and often requires multiple surgeries to obtain intraocular pressure control. Keywords: Congenital ectropion uvea, Juvenile glaucoma, Angle-closure glaucoma, Glaucoma drainage device

  6. Colliding and merging galaxies. II. S0 galaxies with polar rings

    International Nuclear Information System (INIS)

    Schweizer, F.; Whitmore, B.D.; Rubin, V.C.

    1983-01-01

    We first present a detailed optical study of A0136-0801, a 16 1/2 -mag ''spindle'' galaxy girdled by a ring of gas, dust, and young stars. The spindle is a normal S0 disk seen nearly edge-on, as shown by its photometric profile and fast rotation (v/sub rot//sigma/sub v/ = 2.2); a prolate structure seems to be ruled out. The surrounding ring runs over the poles of this S0 disk and serves as a probe of the vertical potential. The ring motions suggest that a massive halo extends far beyond the S0 disk (out to 3R 25 ) and that this halo is more nearly spherical than flat. We then list 22 related galaxies and derive that a few percent of all field S0's possess near-polar rings or disks. We suggest that these structures are due to a second event, most likely the transfer of mass from a companion galaxy during a close encounter and occasionally also the merger of a companion. Although accretion occurs presumably at random angles, polar rings are favored statistically because of their slow differential precession and consequent longevity. Alternate evolutionary schemes are also discussed. Finally, we suggest that M82 may be forming a polar ring from former M81 material, and predict that the ''tilted bulge'' of UGC 7576 is an S0 disk seen nearly edge-on

  7. Determination of the gluon polarisation from open charm production at COMPASS

    Energy Technology Data Exchange (ETDEWEB)

    Koblitz, Susanne

    2009-01-27

    One of the main goals of the COMPASS experiment at CERN is the determination of the gluon polarisation in the nucleon, {delta}G/G. It is determined from spin asymmetries in the scattering of 160GeV/c polarised muons on a polarised LiD target. The gluon polarisation is accessed by the selection of photon-gluon fusion (PGF) events. The PGF-process can be tagged through hadrons with high transverse momenta or through charmed hadrons in the final state. The advantage of the open charm channel is that, in leading order, the PGF-process is the only process for charm production, thus no physical background contributes to the selected data sample. This thesis presents a measurement of the gluon polarisation left angle {delta}g/g right angle from the COMPASS data taken in the years 2002-2004. In the analysis, charm production is tagged through a reconstructed D{sup 0}-meson decaying in D{sup 0}{yields} K{sup -}{pi}{sup +} (and charge conjugates). The reconstruction is done on a combinatorial basis. The background of wrong track pairs is reduced using kinematic cuts to the reconstructed D{sup 0}-candidate and the information on particle identification from the Ring Imaging Cerenkov counter. In addition, the event sample is separated into D{sup 0}-candidates, where a soft pion from the decay of the D{sup *}-meson to a D{sup 0}-meson, is found, and the D{sup 0}-candidates without this tag. Due to the small mass difference between D{sup *}-meson and D{sup 0}-meson the signal purity of the D{sup *}-tagged sample is about 7 times higher than in the untagged sample. The gluon polarisation left angle {delta}g/g right angle is measured from the event asymmetries for the for the different spin configurations of the COMPASS target. To improve the statistical precision of the final results, the events in the final sample are weighted. The use of a signal and a background weight allows the separation of left angle {delta}g/g right angle, and a possible asymmetry in the combinatorial

  8. Determination of the gluon polarisation from open charm production at COMPASS

    International Nuclear Information System (INIS)

    Koblitz, Susanne

    2009-01-01

    One of the main goals of the COMPASS experiment at CERN is the determination of the gluon polarisation in the nucleon, ΔG/G. It is determined from spin asymmetries in the scattering of 160GeV/c polarised muons on a polarised LiD target. The gluon polarisation is accessed by the selection of photon-gluon fusion (PGF) events. The PGF-process can be tagged through hadrons with high transverse momenta or through charmed hadrons in the final state. The advantage of the open charm channel is that, in leading order, the PGF-process is the only process for charm production, thus no physical background contributes to the selected data sample. This thesis presents a measurement of the gluon polarisation left angle Δg/g right angle from the COMPASS data taken in the years 2002-2004. In the analysis, charm production is tagged through a reconstructed D 0 -meson decaying in D 0 → K - π + (and charge conjugates). The reconstruction is done on a combinatorial basis. The background of wrong track pairs is reduced using kinematic cuts to the reconstructed D 0 -candidate and the information on particle identification from the Ring Imaging Cerenkov counter. In addition, the event sample is separated into D 0 -candidates, where a soft pion from the decay of the D * -meson to a D 0 -meson, is found, and the D 0 -candidates without this tag. Due to the small mass difference between D * -meson and D 0 -meson the signal purity of the D * -tagged sample is about 7 times higher than in the untagged sample. The gluon polarisation left angle Δg/g right angle is measured from the event asymmetries for the for the different spin configurations of the COMPASS target. To improve the statistical precision of the final results, the events in the final sample are weighted. The use of a signal and a background weight allows the separation of left angle Δg/g right angle, and a possible asymmetry in the combinatorial background. This method results in an average value of the gluon polarisation

  9. Absorptivity modulation on wavy molten steel surfaces: The influence of laser wavelength and angle of incidence

    International Nuclear Information System (INIS)

    Kaplan, A. F. H.

    2012-01-01

    The modulation of the angle-dependent Fresnel absorptivity across wavy molten steel surfaces during laser materials processing, like drilling, cutting, or welding, has been calculated. The absorptivity is strongly altered by the grazing angle of incidence of the laser beam on the processing front. Owing to its specific Brewster-peak characteristics, the 10.64 μm wavelength CO 2 -laser shows an opposite trend with respect to roughness and angle-of-incidence compared to lasers in the wavelength range of 532-1070 nm. Plateaus or rings of Brewster-peak absorptivity can lead to hot spots on a wavy surface, often in close proximity to cold spots caused by shadow domains.

  10. Self-organized formation of GaSb/GaAs quantum rings.

    Science.gov (United States)

    Timm, R; Eisele, H; Lenz, A; Ivanova, L; Balakrishnan, G; Huffaker, D L; Dähne, M

    2008-12-19

    Ring-shaped GaSb/GaAs quantum dots, grown by molecular beam epitaxy, were studied using cross-sectional scanning tunneling microscopy. These quantum rings have an outer shape of a truncated pyramid with baselengths around 15 nm and heights of about 2 nm but are characterized by a clear central opening extending over about 40% of the outer baselength. They form spontaneously during the growth and subsequent continuous capping of GaSb/GaAs quantum dots due to the large strain and substantial As-for-Sb exchange reactions leading to strong Sb segregation.

  11. On the Stability of Pick-up Ion Ring Distributions in the Outer Heliosheath

    Science.gov (United States)

    Summerlin, Errol J.; Viñas, Adolfo F.; Moore, Thomas E.; Christian, Eric R.; Cooper, John F.

    2014-10-01

    The "secondary energetic neutral atom (ENA)" hypothesis for the ribbon feature observed by the Interstellar Boundary Explorer (IBEX) posits that the neutral component of the solar wind continues beyond the heliopause and charge exchanges with interstellar ions in the Outer Heliosheath (OHS). This creates pick-up ions that gyrate about the draped interstellar magnetic field (ISMF) lines at pitch angles near 90° on the locus where the ISMF lies tangential to the heliopause and perpendicular to the heliocentric radial direction. This location closely coincides with the location of the ribbon feature according to the prevailing inferences of the ISMF orientation and draping. The locally gyrating ions undergo additional charge exchange and escape as free-flying neutral atoms, many of which travel back toward the inner solar system and are imaged by IBEX as a ribbon tracing out the locus described above. For this mechanism to succeed, the pick-up ions must diffuse in pitch angle slowly enough to permit secondary charge exchange before their pitch angle distribution substantially broadens away from 90°. Previous work using linear Vlasov dispersion analysis of parallel propagating waves has suggested that the ring distribution in the OHS is highly unstable, which, if true, would make the secondary ENA hypothesis incapable of rendering the observed ribbon. In this paper, we extend this earlier work to more realistic ring distribution functions. We find that, at the low densities necessary to produce the observed IBEX ribbon via the secondary ENA hypothesis, growth rates are highly sensitive to the temperature of the beam and that even very modest temperatures of the ring beam corresponding to beam widths of distributions necessary to produce the observed IBEX ENA flux via the secondary ENA hypothesis will be unstable to their own self-generated turbulence.

  12. The opposition effect in Saturn's main rings as seen by Cassini ISS: 4. Correlations of the surge morphology with surface albedos and VIMS spectral properties

    Science.gov (United States)

    Déau, Estelle; Dones, Luke; Mishchenko, Michael I.; West, Robert A.; Helfenstein, Paul; Hedman, Matt M.; Porco, Carolyn C.

    2018-05-01

    In this paper, we continue our analysis of the saturnian ring opposition effect seen by Cassini ISS. The ring opposition effect is a peak in the rings' reflectivity caused as the directions from a spot on the rings to the observer and to the light source, respectively, converge toward zero degrees. So far, the exact origin of the ring's opposition effect is still a matter of debate. In our previous work (Déau, et al., 2013, Icarus, 226, 591-603), we compared the opposition effect morphology with the rings' optical depth and found that only the slope of the linear part of the rings' phase curves was strongly correlated with the optical depth. We interpreted this as an indication of the predominant role of interparticle shadowing at moderate phase angles (α ∼ 10-40o). More recently (Déau, 2015, Icarus, 253, 311-345), we showed that interparticle shadowing cannot explain the behavior at low phase angles (α Journal Letters, 711, L71-L74). We find that the opposition surge morphology is strongly correlated with the water ice band depth and the regolith albedo. We interpret this finding as an indication that coherent backscattering plays a role in affecting both the water ice band depths and the opposition surge at low phase angles (α < 1o). As the regolith albedo and spectral properties are related to the grain size, porosity, roughness, and composition, we try to assess which of these regolith properties are preponderant in coherent backscattering. Our study is able to narrow down the parameter space of these properties, whose values allow a good match between the angular width predicted by models of coherent backscattering and the width of the observed peak.

  13. Features of ophthalmoneuroprotection in patients with open-angle glaucoma in combination with diabetic retinopathy

    Directory of Open Access Journals (Sweden)

    O. I. Borzunov

    2014-07-01

    Full Text Available Aim: of this study is to evaluate ophthalmoneuroprotectional treatment of patients with POAG and diabetes mellitus type II in a specialized hospital.Material and methods: We have performed retro — and prospective analysis of the combined treatment of 130 patients (248 eyes with a combination of primary open-angle glaucoma and diabetic retinopathy. Evaluation of the effectiveness of treatment was conducted on the following criteria: the severity of the hypotensive effect, the degreeof improvement and duration of remission of major ophthalmic indicators. The patients were divided into four clinical — homogeneous groups: primary — 40 people (77 eyes, the comparison group I — 37 persons (71 eyes, the comparison group II — 33 people (60 eyes, the control group — 20 people (40 eyes.Results: Combination of different treatment strategy of laser and conservative treatment was tested. The result has been designed for optimal balance improving performance and reducing ocular side effects. Retinalamin ® 5 mg parabulbare number 10, Tanakan 1 tablet 3 times a day — 3 months. The optimal timing of re-treatment (at least 1time in 9 months, in the case of significant progression of glaucomatous optic neuropathy — the timing is solved individually.

  14. Influence of Stockpile Angle in Natural Drying of Laterite Ore

    Directory of Open Access Journals (Sweden)

    Yoalbys Retirado-Mediaceja

    2016-10-01

    Full Text Available Natural drying is performed at Cuban nickel plants by depositing bulk ore in the open. The ore is currently being stockpiled without much consideration for the impact of the drying surface angle on the process power behavior. Simulations were carried out in this investigation, which prove that an increased triangular stockpile angle considerably reduces natural drying efficiency. A 45 sexagesimal degree angle to the horizontal plane results in exposure of a large volume of ore to natural drying and guarantees adequate energy performance.

  15. Radiographic investigation of the function of the Bjoerk-Shiley artificial valve

    Energy Technology Data Exchange (ETDEWEB)

    Erdelyi, M Jr [Orszagos Roentgen es Sugarfizikai Intezet, Budapest (Hungary)

    1980-01-01

    The normal opening and closing mechanism of the tip-up valve, containing a metal ring, was investigated by kino and spot-film techniques in 58 patients. A new and simple method was elaborated for the calculation of the opening angle of the tip-up valve, rendering superfluous the complicated calculations published by Bjoerk. In accordance with literature data the regular opening angle of the examined 71 valve prostheses was found to be 60 deg (+-2 deg).

  16. Glaukos iStent inject® Trabecular Micro-Bypass Implantation Associated with Cataract Surgery in Patients with Coexisting Cataract and Open-Angle Glaucoma or Ocular Hypertension: A Long-Term Study

    Directory of Open Access Journals (Sweden)

    Pedro Arriola-Villalobos

    2016-01-01

    Full Text Available Purpose. To evaluate the long-term efficacy and safety of the iStent inject device (Glaukos Corporation, Laguna Hills, CA combined with phacoemulsification in patients with coexistent cataract and open-angle glaucoma or ocular hypertension (OHT. Methods. A prospective, uncontrolled, nonrandomized, interventional case series study was conducted in patients with both mild or moderate open-angle glaucoma or OHT and cataract. Patients underwent cataract surgery along with the implant of two iStent inject devices. Outcome measures were intraocular pressure (IOP, topical hypotensive medications required, and best-corrected visual acuity (BCVA. Results. 20 patients were enrolled. Mean follow-up was 47.4±18.46 months. Mean baseline IOP was 19.95±3.71 mmHg with medication and 26±3.11 mmHg after washout. Mean end-follow-up IOP was 16.25±1.99 mmHg, representing an IOP decrease of 36.92%, 9.74±3.14 mmHg (P<0.001, from baseline washout IOP. The mean number of medications was significantly reduced from 1.3±0.66 to 0.75±0.79 (P=0.017. 45% of patients were medication-free by the end of follow-up. Mean log⁡MAR BCVA improved significantly from 0.42±0.16 to 0.18±0.16 (P<0.001. No complications of surgery were observed. Conclusion. The iStent inject device combined with cataract surgery served to significantly reduce both IOP and medication use in the long term in patients with coexistent open-angle glaucoma or ocular hypertension (OHT and cataract.

  17. The Effect of Confluence Angle on the Flow Pattern at a Rectangular Open-Channel

    Directory of Open Access Journals (Sweden)

    F. Rooniyan

    2014-02-01

    Full Text Available Flow connection in channels is a phenomenon which frequently happens in rivers, water and drainage channels and urban sewage systems. The phenomenon appears to be more complex in rivers than in channels, especially at the y-junction bed joint that causes erosion and sedimentation at some areas resulting to morphological changes. Flow behavior at the channel junction area depends on variables such as channel geometry, discharge ratio, tributary width and y-junction connection angle of the channel, bed level changes at the bed joint, flow characteristic at the bed joint upstream and flow Froude number in different sections. In this research, fluent numerical model and junction angles of 30o, 45o & 60o are used to analyze and evaluate the effect of channel junction geometry on the flow pattern and the flow separation zone dimensions in different ratios of flow discharge (upstream channel discharge to total discharge of the flow. Results for two ratios of flow discharge are represented. Results are in agreement with earlier studies and it is shown that the change of the channel crossing angle affects the flow pattern in the main channel and also that the dimensions of the created separation zone in the main channel become larger when the crossing angle increases. This phenomenon can also be observed when the flow discharge ratio is lower. Analysis showed that the least dimension of the separation zone will be at the crossing angle of 45o .

  18. Preservative-free bimatoprost 0.03% in patients with primary open-angle glaucoma or ocular hypertension in clinical practice

    Directory of Open Access Journals (Sweden)

    Pillunat LE

    2016-09-01

    Full Text Available Lutz E Pillunat,1 Peter Eschstruth,2 Stefan Häsemeyer,3 Ulrich Thelen,4 Christian Foja,5 Richard Leaback,6 Stefan Pfennigsdorf7 1Department of Ophthalmology, University Hospital Carl Gustav Carus, Dresden, 2Ophthalmology Practice, Kiel, 3Eye Center Kraichgau, Wiesloch, 4Department of Ophthalmology, University of Münster, Münster, 5Ophthalmology Practice, Leipzig, Germany; 6Allergan Holdings Ltd., Marlow, UK; 7Ophthalmology Practice, Polch, Germany Background: Intraocular pressure (IOP-lowering medications for primary open-angle glaucoma and ocular hypertension commonly contain preservatives that can cause ocular surface damage in many patients. The purpose of this study was to evaluate the efficacy and tolerability of, and compliance to, preservative-free (PF bimatoprost 0.03% in patients with primary open-angle glaucoma or ocular hypertension (IOP ≥18 mmHg in a clinical practice setting. Methods: This open-label study observed patients who were switched to PF bimatoprost 0.03% for medical reasons. IOP was measured at baseline and ~12 weeks later at the final visit, and the change in IOP was calculated. Tolerability and continuation of therapy were assessed at two follow-up visits. Results: A total of 1,830 patients were included in the study, and complete IOP data were available for 1,543 patients. Mean IOP was reduced by 23% from 21.64 mmHg to 16.59 mmHg (P<0.0001. In subgroup analyses, the mean IOP was significantly reduced compared with baseline, regardless of prior therapy, including those previously treated with PF monotherapy. A total of 85.7% of physicians reported the IOP-lowering efficacy of PF bimatoprost 0.03% to be as expected or better than expected. Adverse events (AEs were experienced by 5.7% of patients, and there were no serious AEs reported. The most common AEs were eye irritation (1.7% and hyperemia (1.4%. Physician-reported treatment compliance was reported as better than (48.7% or equal to (43.6% prior treatment in

  19. [The effect of parenteral citicoline on visual functions and life quality of patients with primary open-angle glaucoma].

    Science.gov (United States)

    Frolov, M A; Gonchar, P A; Barashkov, V I; Kumar, V; Morozova, N S; Frolov, A M; Kazakova, K A

    2011-01-01

    The effect of nootropic drug citicoline on visual functions, perimetric indexes of static automated perimetry, morphometric characteristics of retinal tomography and life quality of patients with primary open-angle glaucoma (POAG) stage I-III and normalized intraocular pressure (IOP) was studied. 40 patients aged 46-78 years old with POAG stage I-III and normalized IOP were treated with citicoline. Among them there were 24 female and 16 male. The patients were divided into 2 equal groups--experimental and control. Patients of both groups were treated with intravenous citicoline for 10 days. The dose of citicoline in experimental group was 1000 mg/day, in control--500 mg/day. After treatment in both groups visual functions, perimetric indexes of static automated perimetry, morphometric characteristics of retinal tomography and life quality showed improvement. Citicoline has significant neuroprotective effect preventing apoptosis.

  20. Anterior segment changes after pharmacologic mydriasis using Pentacam and optical coherence tomography in angle closure suspects

    Directory of Open Access Journals (Sweden)

    Jing-Min Guo

    2015-10-01

    Full Text Available AIM:To compare the dynamic changes of anterior segment parameters especially iris morphology induced by pharmacologic mydriasis between angle closure suspects and normal controls.METHODS:The study group comprised 19 eyes of 19 angle closure suspects and 19 eyes of 19 age- and sex-matched normal open-angle eyes. Pentacam and optical coherence tomography measurements before and 30min after instillation of compound tropicamide eye drop were performed and compared. Biometric evaluations of iris tomography and anterior chamber angle were estimated by a customized image-processing software.RESULTS:Baseline axial length, iris cross sectional area and volume did not differ significantly between angle closure suspects and normal controls. Angle closure suspects had smaller pupil size, narrower anterior segment dimension and axial length, thinner iris with greater curve in comparison with normal controls. Pharmacologic mydriasis led to significant increments in iris thickness at 750 μm, anterior chamber depth and volume, whereas significant decrements in iris curve, cross sectional area and volume in both groups. Angle opening distance at 500 μm was increased significantly in normal controls (from 0.465±0.115 mm to 0.539±0.167 mm, P=0.009, but not in angle closure suspects (from 0.125±0.100 mm to 0.145±0.131 mm, P=0.326. Iris volume change per millimeter of pupil dilation (△IV/△PD decreased significantly less in angle closure suspects than normal controls (-2.47±1.33 mm2 vs -3.63±1.58 mm2, P=0.019. Linear regression analysis showed that the change of angle opening distance at 500 μm was associated most with the change of central anterior chamber depth (β=0.841, P=0.002 and △IV/△PD (β=0.028, P=0.002, followed by gender (β=0.062, P=0.032.CONCLUSION:Smaller iris volume decrement per millimeter of pupil dilation is related significantly with the less anterior angle opening in angle closure suspects after pharmacologic mydriasis. Dynamic

  1. A Stereoselective [3+1] Ring Expansion for the Synthesis of Highly Substituted Methylene Azetidines.

    Science.gov (United States)

    Schmid, Steven C; Guzei, Ilia A; Schomaker, Jennifer M

    2017-09-25

    The reaction of rhodium-bound carbenes with strained bicyclic methylene aziridines results in a formal [3+1] ring expansion to yield highly substituted methylene azetidines with excellent regio- and stereoselectivity. The reaction appears to proceed through an ylide-type mechanism, where the unique strain and structure of the methylene aziridine promotes a ring-opening/ring-closing cascade that efficiently transfers chirality from substrate to product. The resultant products can be elaborated into new azetidine scaffolds containing vicinal tertiary-quaternary and even quaternary-quaternary stereocenters. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Some hadron calorimeter properties relevant to storage rings

    International Nuclear Information System (INIS)

    Corden, M.J.; Dowell, J.D.; Edwards, M.; Ellis, N.; Garvey, J.; Grant, D.; Homer, R.J.; Kenyon, I.R.; McMahon, T.; Schanz, G.; Sumorok, K.C.T.O.; Watkins, P.M.; Wilson, J.A.; Eisenhandler, E.; Gibson, W.R.; Kalmus, P.I.P.; Thompson, G.; Arnison, G.; Astbury, A.; Grayer, G.; Haynes, W.J.; Hill, D.; Nandi, A.K.; Roberts, C.; Shah, T.P.

    1982-01-01

    At wide angles in a storage ring environment, a substantial part of the energy seen by a hadron calorimeter can be in the form of very low momentum particles such as jet fragments or resonance cascade decay products. Data are presented on the deviations from Gaussian resolution and linear response for such low momentum particles. The differing responses to incident e - , μ - , π +- , K +- , p and anti p at momenta below 10 GeV/c are also compared. In addition, the authors discuss the significance of angle effects for a 4π calorimeter, and the problems of combining data from calorimeters with different physical characteristics. Experimental data are presented on the difference in hadron response between a fine grain (electromagnetic) lead calorimeter and a coarser (hadron) iron calorimeter, and on the dependence of the response on the energy sharing between the two calorimeters. (Auth.)

  3. CIRS High-Resolution Thermal Scans and the Structure of Saturn's B Ring

    Science.gov (United States)

    Brooks, S. M.; Spilker, L. J.; Showalter, M.; Pilorz, S.; Edgington, S. G.

    2017-12-01

    The flyby of Titan on November 29, 2016, sent the Cassini spacecraft on a trajectory that would take it within 10,000 kilometers of Saturn's F ring multiple times before a subsequent Titan encounter on April 22, 2017, would send it on ballistic trajectory carrying it between Saturn's cloud tops and the planet's D ring for several flybys. This geometry has proven beneficial for high-resolution studies of the rings, not just because of Cassini's proximity to the rings, but also because of the spacecraft's high elevation angle above the rings, which reduces the foreshortening that tends to degrade resolution in the ring plane. We will report on several observations of Saturn's main rings at the high spatial resolutions enabled by the end-of-mission geometry, particulary the B ring, with the Composite Infrared Spectrometer onboard Cassini during the F-ring and proximal orbits. CIRS' three infrared detectors cover a combined spectral range of 10 to 1400 cm-1 (1 mm down to 7 microns). We focus on data from Focal Plane 1, which covers the 10 to 600 cm-1 range (1 mm to 16 microns). The apodized spectral resolution of the instrument can be varied from 15 cm-1 to 0.5 cm-1 (Flasar et al. 2004). FP1's wavelength range makes it well-suited to sensing thermal emission from objects at temperatures typical of Saturn's rings. Correlating ring optical depth with temperatures retrieved from scans of the face of the rings exposed to direct solar illumination (the lit face) and the opposite (unlit) face suggests differences in ring structure or particle transport between the lit and unlit sides of the rings in different regions of the B ring. Lit side temperatures in the core of the B ring range between 82 and 87 K; temperatures on the unlit side of the core vary from 66 K up to 74 K. Ferrari and Reffet (2013) and Pilorz et al. (2015) published thorough analyses of the thermal throughput across this optically thick ring. We will discuss these recent CIRS rings observations and their

  4. Open angle glaucoma in a case of Type IV Ehler Danlos syndrome: a rarely reported association.

    Science.gov (United States)

    Mitra, Arijit; Ramakrishnan, R; Kader, Mohideen Abdul

    2014-08-01

    A 26-year-old male presented to us with defective vision in the left eye. He had best corrected visual acuity (BCVA) of hand movement (HM) in right eye and 6/9 in left eye. He had ptosis with ectropion in both eyes and relative afferent pupillary defect (RAPD) in right eye. Intraocular pressure (IOP) was 46 and 44 mmHg in right and left eye, respectively. Fundus showed glaucomatous optic atrophy (GOA) in right eye and cup disc ratio (CDR) of 0.75 with bipolar rim thinning in left eye. Systemic examination showed hyperextensible skin and joints, acrogeria, hypodontia, high arched palate, and varicose veins. He gave history of easy bruising and tendency to fall and history of intestinal rupture 5 years ago for which he had undergone surgery. He was diagnosed as a case of Type IV Ehler-Danlos syndrome (EDS) with open angle glaucoma. He underwent trabeculectomy in both eyes. This is a rare case that shows glaucoma in a patient of EDS Type IV. Very few such cases have been reported in literature.

  5. Open angle glaucoma in a case of Type IV Ehler Danlos syndrome: A rarely reported association

    Directory of Open Access Journals (Sweden)

    Arijit Mitra

    2014-01-01

    Full Text Available A 26-year-old male presented to us with defective vision in the left eye. He had best corrected visual acuity (BCVA of hand movement (HM in right eye and 6/9 in left eye. He had ptosis with ectropion in both eyes and relative afferent pupillary defect (RAPD in right eye. Intraocular pressure (IOP was 46 and 44 mmHg in right and left eye, respectively. Fundus showed glaucomatous optic atrophy (GOA in right eye and cup disc ratio (CDR of 0.75 with bipolar rim thinning in left eye. Systemic examination showed hyperextensible skin and joints, acrogeria, hypodontia, high arched palate, and varicose veins. He gave history of easy bruising and tendency to fall and history of intestinal rupture 5 years ago for which he had undergone surgery. He was diagnosed as a case of Type IV Ehler-Danlos syndrome (EDS with open angle glaucoma. He underwent trabeculectomy in both eyes. This is a rare case that shows glaucoma in a patient of EDS Type IV. Very few such cases have been reported in literature.

  6. RAND-like appropriateness methodology consensus for primary open-angle glaucoma in Latin America.

    Science.gov (United States)

    Lerner, S Fabian; Singh, Kuldev; Susanna, Remo; Wilson, M Roy; Lee, Brian L; Maul, Eugenio

    2012-09-01

    To report the results of a Latin American consensus panel regarding the diagnosis and management of primary open-angle glaucoma and to compare these results with those from a similar panel in the United States. A RAND-like (Research and Development) appropriateness methodology was used to assess glaucoma practice in Latin America. The 148 polling statements created for the RAND- like analysis in the United States and 10 additional statements specific to glaucoma care in Latin America were presented to a panel of Latin American glaucoma experts. Panelists were polled in private using the RAND- like methodology before and after the panel meeting. Consensus agreement or disagreement among Latin American experts was reached for 51.3% of statements before the meeting and increased to 66.5% in the private, anonymous meeting after polling (79.0% agreement, 21.0% disagreement). Although there was a high degree of concordance (111 of 148 statements; 75%) between the results of this Latin American panel and the United States panel, there were some notable exceptions relating to diagnostic and therapeutic decision making. This RAND-like consensus methodology provides a perspective of how Latin American glaucoma practitioners view many aspects of glaucoma and compares these results with those obtained using a similar methodology from practitioners in the United States. These findings may be helpful to ophthalmologists providing glaucoma care in Latin America and in other regions of the world. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Gap States at Low-Angle Grain Boundaries in Monolayer Tungsten Diselenide

    KAUST Repository

    Huang, Yu Li

    2016-05-03

    Two-dimensional (2D) transition metal dichalcogenides (TMDs) have revealed many novel properties of interest to future device applications. In particular, the presence of grain boundaries (GBs) can significantly influence the material properties of 2D TMDs. However, direct characterization of the electronic properties of the GB defects at the atomic scale remains extremely challenging. In this study, we employ scanning tunneling microscopy and spectroscopy to investigate the atomic and electronic structure of low-angle GBs of monolayer tungsten diselenide (WSe2) with misorientation angles of 3-6°. Butterfly features are observed along the GBs, with the periodicity depending on the misorientation angle. Density functional theory calculations show that these butterfly features correspond to gap states that arise in tetragonal dislocation cores and extend to distorted six-membered rings around the dislocation core. Understanding the nature of GB defects and their influence on transport and other device properties highlights the importance of defect engineering in future 2D device fabrication. © 2016 American Chemical Society.

  8. Gap States at Low-Angle Grain Boundaries in Monolayer Tungsten Diselenide

    KAUST Repository

    Huang, Yu Li; Ding, Zijing; Zhang, Wenjing; Chang, Yung-Huang; Shi, Yumeng; Li, Lain-Jong; Song, Zhibo; Zheng, Yu Jie; Chi, Dongzhi; Quek, Su Ying; Wee, Andrew T. S.

    2016-01-01

    Two-dimensional (2D) transition metal dichalcogenides (TMDs) have revealed many novel properties of interest to future device applications. In particular, the presence of grain boundaries (GBs) can significantly influence the material properties of 2D TMDs. However, direct characterization of the electronic properties of the GB defects at the atomic scale remains extremely challenging. In this study, we employ scanning tunneling microscopy and spectroscopy to investigate the atomic and electronic structure of low-angle GBs of monolayer tungsten diselenide (WSe2) with misorientation angles of 3-6°. Butterfly features are observed along the GBs, with the periodicity depending on the misorientation angle. Density functional theory calculations show that these butterfly features correspond to gap states that arise in tetragonal dislocation cores and extend to distorted six-membered rings around the dislocation core. Understanding the nature of GB defects and their influence on transport and other device properties highlights the importance of defect engineering in future 2D device fabrication. © 2016 American Chemical Society.

  9. Planar LIF observation of unburned fuel escaping the upper ring-land crevice in an SI engine

    Energy Technology Data Exchange (ETDEWEB)

    Green, R.M.; Cloutman, L.D.

    1997-01-01

    PLIF has been used to observe the in-cylinder transport of unburned fuel that, while trapped in the ring-land and ring-groove crevices, survives combustion in the propagating flame. Away from the top-ring gap, we detect a wall-jet comprised of unburned charge exiting the top ring-land crevice opening. At the location of the top-ring gap, we observed unburned fuel lying in the cool boundary layer along the cylinder wall during the later stages of the expansion stroke. This layer is scraped into the roll-up vortex during the exhaust stroke. These data lead us to conclude that away from the end gap, unburned, high pressure charge, trapped between the two compression rings escapes as a wall jet after ring-reversal near the bottom center. Conversely, at the ring gap, when the cylinder pressure drops below the pressure between the compression rings, the trapped charge escapes through the gap and forms a thin layer on the cylinder wall.

  10. Beam Optics for FCC-ee Collider Ring

    CERN Document Server

    Oide, Katsunobu; Aumon, S; Benedikt, M; Blondel, A; Bogomyagkov, A V; Boscolo, M; Burkhardt, H; Cai, Y; Doblhammer, A; Haerer, B; Holzer, B; Koop, I; Koratzinos, M; Jowett, John M; Levichev, E B; Medina, L; Ohmi, K; Papaphilippou, Y; Piminov, P A; Shatilov, D N; Sinyatkin, S V; Sullivan, M; Wenninger, J; Wienands, U; Zhou, D; Zimmermann, F

    2017-01-01

    A beam optics scheme has been designed [ 1 ] for the Future Circular Collider- e + e − (FCC-ee). The main characteristics of the design are: beam energy 45 to 175 GeV, 100 km circumference with two interaction points (IPs) per ring, horizontal crossing angle of 30 mrad at the IP and the crab-waist scheme [ 2 ] with local chromaticity correction. The crab-waist scheme is implemented within the local chromaticity correction system without additional sextupoles, by reducing the strength of one of the two sextupoles for vertical chromatic correction at each side of the IP. So- called “tapering" of the magnets is applied, which scales all fields of the magnets according to the local beam energy to compensate for the effect of synchrotron radiation (SR) loss along the ring. An asymmetric layout near the interaction region reduces the critical energy of SR photons on the incoming side of the IP to values below 100 keV, while matching the geometry to the beam line of the FCC proton collider (FCC-hh) [ 3 ] as clos...

  11. Cherenkov angle and charge reconstruction with the RICH detector of the AMS experiment

    CERN Document Server

    Barão, F; Borges, J; Gonçalves, P; Pimenta, M; Pérez, I

    2003-01-01

    The Alpha Magnetic Spectrometer experiment to be installed on the International Space Station will be equipped with a proximity focusing Ring Imaging Cherenkov (RICH) detector, for measurements of particle electric charge and velocity. In this note, two possible methods for reconstructing the Cherenkov angle and the electric charge with the RICH are discussed. A Likelihood method for the Cherenkov angle reconstruction was applied leading to a velocity determination for protons with a resolution of around 0.1%. The existence of a large fraction of background photons which can vary from event to event implied a charge reconstruction method based on an overall efficiency estimation on an event-by-event basis.

  12. Synergistic dual activation catalysis by palladium nanoparticles for epoxide ring opening with phenols.

    Science.gov (United States)

    Seth, Kapileswar; Roy, Sudipta Raha; Pipaliya, Bhavin V; Chakraborti, Asit K

    2013-07-04

    Synergistic dual activation catalysis has been devised for epoxide phenolysis wherein palladium nanoparticles induce electrophilic activation via coordination with the epoxide oxygen followed by nucleophilic activation through anion-π interaction with the aromatic ring of the phenol, and water (reaction medium) also renders assistance through 'epoxide-phenol' dual activation.

  13. LHC Report: playing with angles

    CERN Multimedia

    Mike Lamont for the LHC team

    2016-01-01

    Ready (after a machine development period), steady (running), go (for a special run)!   The crossing angles are an essential feature of the machine set-up. They have to be big enough to reduce the long-range beam-beam effect. The LHC has recently enjoyed a period of steady running and managed to set a new record for “Maximum Stable Luminosity Delivered in 7 days” of 3.29 fb-1 between 29 August and 4 September. The number of bunches per beam remains pegged at 2220 because of the limitations imposed by the SPS beam dump. The bunch population is also somewhat reduced due to outgassing near one of the injection kickers at point 8. Both limitations will be addressed during the year-end technical stop, opening the way for increased performance in 2017. On 10 and 11 September, a two day machine development (MD) period took place. The MD programme included a look at the possibility of reducing the crossing angle at the high-luminosity interaction points. The crossing angles are an ess...

  14. Black rings

    International Nuclear Information System (INIS)

    Emparan, Roberto; Reall, Harvey S

    2006-01-01

    A black ring is a five-dimensional black hole with an event horizon of topology S 1 x S 2 . We provide an introduction to the description of black rings in general relativity and string theory. Novel aspects of the presentation include a new approach to constructing black ring coordinates and a critical review of black ring microscopics. (topical review)

  15. Lateral angle: a method for sexing using the petrous bone

    DEFF Research Database (Denmark)

    Norén, Anna; Lynnerup, Niels; Czarnetzki, Alfred

    2005-01-01

    skeletal remains or cremated bones, where the petrous bone may still be readily recognizable. The method was tested using a forensic sample of 113 petrous bones with known sex. Intra- and interobserver testing was also performed. We found a statistically significant difference in angle size between males...... and females (mean angle size of males, 39.3 degrees ; mean angle size of females, 48.2 degrees ; P tested the lateral angle method against an archaeological skeletal...... of the proximal part of the internal acoustic canal and determining the angle at which the canal opens up to the surface of the petrous bone. The method has the great advantage of utilizing one of the sturdiest bone elements of the human skeleton, and may thus be especially suited for analyses of very fragmented...

  16. Relationship between consecutive deterioration of mean deviation value and progression of visual field defect in open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    Naito T

    2015-11-01

    Full Text Available Tomoko Naito,1 Keiji Yoshikawa,2 Shiro Mizoue,3 Mami Nanno,4 Tairo Kimura,5 Hirotaka Suzumura,6 Ryuji Takeda,7 Fumio Shiraga1 1Department of Ophthalmology, Okayama University Graduate School of Medicine, Okayama, 2Yoshikawa Eye Clinic, Tokyo, 3Department of Ophthalmology, Ehime University Graduate School of Medicine, Ehime, 4Kagurazaka Minamino Eye Clinic, 5Ueno Eye Clinic, 6Suzumura Eye Clinic, Tokyo, 7Department of Agriculture, Kinki University, Nara, Japan Purpose: To analyze the relationship between consecutive deterioration of mean deviation (MD value and glaucomatous visual field (VF progression in open-angle glaucoma (OAG, including primary OAG and normal tension glaucoma.Patients and methods: The subjects of the study were patients undergoing treatment for OAG who had performed VF tests at least 10 times with a Humphrey field analyzer (SITA standard, C30-2 program. The VF progression was defined by a significantly negative MD slope (MD slope worsening at the final VF test during the follow-up period. The relationship between the MD slope worsening and the consecutive deterioration of MD value were retrospectively analyzed.Results: A total of 165 eyes of 165 patients were included in the analysis. Significant progression of VF defects was observed in 72 eyes of 72 patients (43.6%, while no significant progression was evident in 93 eyes of 93 patients (56.4%. There was significant relationship between the frequency of consecutive deterioration of MD value and MD slope worsening (P<0.0001, Cochran–Armitage trend test. A significant association was observed for MD slope worsening in the eyes with three (odds ratio: 2.1, P=0.0224 and four (odds ratio: 3.6, P=0.0008 consecutive deterioration of MD value in multiple logistic regression analysis, but no significant association in the eyes with two consecutive deterioration (odds ratio: 1.1, P=0.8282. The eyes with VF progression had significantly lower intraocular pressure reduction rate (P<0

  17. Small angle x-ray scattering from proteins in solution

    International Nuclear Information System (INIS)

    de Souza, C.F.; Torriani, I.L.; Bonafe, C.F.S.; Merrelles, N.C.; Vachette, P.

    1989-01-01

    In this work the authors report experiments performed with giant respiratory proteins from annelids (erythrocruorins), known to have a molecular weight in the order of four million Daltons. Preliminary x-ray scattering data was obtained using a conventional rotating anode source. High resolution small angle scattering curves were obtained with synchrotron radiation from the DCI storage ring at LURE. Data from solutions with several protein concentrations were analyzed in order to determine low resolution dimensional parameters, using Guinier plots from the smeared scattering curves and the inverse transformation method

  18. Variations in Ring Particle Cooling across Saturn's Rings with Cassini CIRS

    Science.gov (United States)

    Brooks, S. M.; Spilker, L. J.; Pilorz, S.; Edgington, S. G.; Déau, E.; Altobelli, N.

    2010-12-01

    Cassini's Composite Infrared Spectrometer has recorded over two million of spectra of Saturn's rings in the far infrared since arriving at Saturn in 2004. CIRS records far infrared radiation between 10 and 600 cm-1 ( 16.7 and 1000 μ {m} ) at focal plane 1 (FP1), which has a field of view of 3.9 mrad. Thermal emission from Saturn’s rings peaks in this wavelength range. Ring temperatures can be inferred from FP1 data. By tracking how ring temperatures vary, we can determine the thermal inertia of the rings. Previous studies have shown that the rings' thermal inertia, a measure of their response to changes in the thermal environment, varies from ring to ring. Thermal inertia can provide insight into the physical structure of Saturn's ring particles and their regoliths. Low thermal inertia and rapidly changing temperatures are suggestive of ring particles that have more porous or fluffy regoliths or that are riddled with cracks. Solid particles can be expected to have higher thermal inertias. Ferrari et al. (2005) fit thermal inertia values of 5218 {Jm)-2 {K}-1 {s}-1/2 to their B ring data and 6412 {Jm)-2 {K}-1 {s}-1/2 to their C ring data. In this work we focus on CIRS observations of the shadowed portion of Saturn's rings. The rings’ thermal budget is dominated by its absorption of solar radiation. As a result, ring particles abruptly cool as they traverse Saturn's shadow. From these shadow observations we can create cooling curves at specific locations across the rings. We will show that the rings' cooling curves and thus their thermal inertia vary not only from ring to ring, but by location within the individual rings. This research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under contract with NASA. Copyright 2010 California Institute of Technology. Government sponsorship acknowledged.

  19. Variable angle asymmetric cut monochromator

    International Nuclear Information System (INIS)

    Smither, R.K.; Fernandez, P.B.

    1993-09-01

    A variable incident angle, asymmetric cut, double crystal monochromator was tested for use on beamlines at the Advanced Photon Source (APS). For both undulator and wiggler beams the monochromator can expand area of footprint of beam on surface of the crystals to 50 times the area of incident beam; this will reduce the slope errors by a factor of 2500. The asymmetric cut allows one to increase the acceptance angle for incident radiation and obtain a better match to the opening angle of the incident beam. This can increase intensity of the diffracted beam by a factor of 2 to 5 and can make the beam more monochromatic, as well. The monochromator consists of two matched, asymmetric cut (18 degrees), silicon crystals mounted so that they can be rotated about three independent axes. Rotation around the first axis controls the Bragg angle. The second rotation axis is perpendicular to the diffraction planes and controls the increase of the area of the footprint of the beam on the crystal surface. Rotation around the third axis controls the angle between the surface of the crystal and the wider, horizontal axis for the beam and can make the footprint a rectangle with a minimum. length for this area. The asymmetric cut is 18 degrees for the matched pair of crystals, which allows one to expand the footprint area by a factor of 50 for Bragg angles up to 19.15 degrees (6 keV for Si[111] planes). This monochromator, with proper cooling, will be useful for analyzing the high intensity x-ray beams produced by both undulators and wigglers at the APS

  20. Health Impact Assessment of a Predicted Air Quality Change by Moving Traffic from an Urban Ring Road into a Tunnel. The Case of Antwerp, Belgium.

    Science.gov (United States)

    Van Brusselen, Daan; Arrazola de Oñate, Wouter; Maiheu, Bino; Vranckx, Stijn; Lefebvre, Wouter; Janssen, Stijn; Nawrot, Tim S; Nemery, Ben; Avonts, Dirk

    2016-01-01

    The Antwerp ring road has a traffic density of 300,000 vehicles per day and borders the city center. The 'Ringland project' aims to change the current 'open air ring road' into a 'filtered tunneled ring road', putting the entire urban ring road into a tunnel and thus filtering air pollution. We conducted a health impact assessment (HIA) to quantify the possible benefit of a 'filtered tunneled ring road', as compared to the 'open air ring road' scenario, on air quality and its long-term health effects. We modeled the change in annual ambient PM2.5 and NO2 concentrations by covering 15 kilometers of the Antwerp ring road in high resolution grids using the RIO-IFDM street canyon model. The exposure-response coefficients used were derived from a literature review: all-cause mortality, life expectancy, cardiopulmonary diseases and childhood Forced Vital Capacity development (FVC). Our model predicts changes between -1.5 and +2 μg/m³ in PM2.5 within a 1,500 meter radius around the ring road, for the 'filtered tunneled ring road' scenario as compared to an 'open air ring road'. These estimated annual changes were plotted against the population exposed to these differences. The calculated change of PM2.5 is associated with an expected annual decrease of 21 deaths (95% CI 7 to 41). This corresponds with 11.5 deaths avoided per 100,000 inhabitants (95% CI 3.9-23) in the first 500 meters around the ring road every year. Of 356 schools in a 1,500 meter perimeter around the ring road changes between -10 NO2 and + 0.17 μg/m³ were found, corresponding to FVC improvement of between 3 and 64ml among school-age children. The predicted decline in lung cancer mortality and incidence of acute myocardial infarction were both only 0.1 per 100,000 inhabitants or less. The expected change in PM2,5 and NO2 by covering the entire urban ring road in Antwerp is associated with considerable health gains for the approximate 352,000 inhabitants living in a 1,500 meter perimeter around the

  1. Health Impact Assessment of a Predicted Air Quality Change by Moving Traffic from an Urban Ring Road into a Tunnel. The Case of Antwerp, Belgium.

    Directory of Open Access Journals (Sweden)

    Daan Van Brusselen

    Full Text Available The Antwerp ring road has a traffic density of 300,000 vehicles per day and borders the city center. The 'Ringland project' aims to change the current 'open air ring road' into a 'filtered tunneled ring road', putting the entire urban ring road into a tunnel and thus filtering air pollution. We conducted a health impact assessment (HIA to quantify the possible benefit of a 'filtered tunneled ring road', as compared to the 'open air ring road' scenario, on air quality and its long-term health effects.We modeled the change in annual ambient PM2.5 and NO2 concentrations by covering 15 kilometers of the Antwerp ring road in high resolution grids using the RIO-IFDM street canyon model. The exposure-response coefficients used were derived from a literature review: all-cause mortality, life expectancy, cardiopulmonary diseases and childhood Forced Vital Capacity development (FVC.Our model predicts changes between -1.5 and +2 μg/m³ in PM2.5 within a 1,500 meter radius around the ring road, for the 'filtered tunneled ring road' scenario as compared to an 'open air ring road'. These estimated annual changes were plotted against the population exposed to these differences. The calculated change of PM2.5 is associated with an expected annual decrease of 21 deaths (95% CI 7 to 41. This corresponds with 11.5 deaths avoided per 100,000 inhabitants (95% CI 3.9-23 in the first 500 meters around the ring road every year. Of 356 schools in a 1,500 meter perimeter around the ring road changes between -10 NO2 and + 0.17 μg/m³ were found, corresponding to FVC improvement of between 3 and 64ml among school-age children. The predicted decline in lung cancer mortality and incidence of acute myocardial infarction were both only 0.1 per 100,000 inhabitants or less.The expected change in PM2,5 and NO2 by covering the entire urban ring road in Antwerp is associated with considerable health gains for the approximate 352,000 inhabitants living in a 1,500 meter perimeter

  2. 360-degree suture trabeculotomy ab interno to treat open-angle glaucoma: 2-year outcomes

    Science.gov (United States)

    Sato, Tomoki; Kawaji, Takahiro; Hirata, Akira; Mizoguchi, Takanori

    2018-01-01

    Purpose The purpose of this study was to evaluate the efficacy of 360-degree suture trabeculotomy (360S-LOT) ab interno for treating open-angle glaucoma (OAG). Risk factors of surgical failure were examined. Patients and methods 360S-LOT ab interno alone was performed for patients with uncontrolled OAG, and combined 360S-LOT ab interno/phacoemulsification was performed for patients with controlled OAG with a visually significant cataract between March 2014 and September 2015 at a single center. The patients were prospectively followed for 2 years. The main outcome measures included 2-year intraocular pressure (IOP), number of anti-glaucoma medications used, postoperative complications, and predictive factors of surgical failure. Kaplan–Meier analysis was performed, with surgical success (with or without medication use) defined as postoperative IOP ≤15 mmHg and IOP reduction ≥20% (criterion A) or IOP ≤12 mmHg and IOP reduction ≥30% (criterion B). Predictive factors were evaluated using Cox proportional hazard ratios. Results A total of 64 eyes of 64 patients were included, and 50 (78%) eyes of 64 eyes underwent a phacoemulsification combination procedure. Surgery significantly reduced IOP from 18.4 ± 2.9 mmHg before surgery to 13.4 ± 3.0 mmHg after surgery (P interno procedure is a favorable option for treating eyes with mild or moderate OAG. PMID:29844656

  3. The non-planar single-frequency ring laser with variable output coupling

    Science.gov (United States)

    Wu, Ke-ying; Yang, Su-hui; Wei, Guang-hui

    2002-03-01

    We put forward a novel non-planar single-frequency ring laser, which consists of a corner cube prism and a specially cut Porro prism made by Nd:YAG crystal. The relative angle between the corner cube and the Porro prism could be adjusted to control the output coupling of the laser resonator and the polarization-state of the output laser. A 1.06 μm single-frequency laser with 1 W output has been obtained.

  4. Combined phacocanaloplasty for open-angle glaucoma and cataract: 12 months results

    Directory of Open Access Journals (Sweden)

    Genaidy MM

    2017-12-01

    Full Text Available Mahmoud Mohamed Genaidy, Hosny Ahmed Zein, Ahmed Mostafa Eid Department of Ophthalmology, Faculty of Medicine, Minia University, Minia, Egypt Purpose of the study: To evaluate efficacy, safety, and success rates of canaloplasty combined with phacoemulsification and intraocular lens implantation in patients with open-angle glaucoma (OAG and visually significant cataract.Patients and methods: A prospective interventional noncomparative case series carried out in Minia University Hospital from April 2015 to October 2016 on 20 eyes of 18 patients who had visually significant cataract and primary OAG. All the cases had combined phacocanaloplasty. Preoperative best-corrected visual acuity, intraocular pressure (IOP, and number of antiglaucoma medications were collected and compared to postoperative levels, and complications rates were recorded.Results: 20 eyes of 18 patients (5 males and 15 females, with a mean age 57.6 years (range 48–69 years, underwent phacocanaloplasty. Preoperative mean IOP was 25.20 ±1.009 mmHg. Postoperative IOP decreased to a mean of 14.20±0.9, 14.85±0.8, and 15.85±0.7 mmHG at 3, 6, and 12 months, respectively, with 37% reduction from preoperative IOP level at one year follow-up visit (P=0.0005. The number of antiglaucoma medications dropped from mean of 1.55 preoperatively to 0.35 postoperatively. LogMAR of best-corrected visual acuity improved from 0.6950±0.07 preoperatively to 0.3670±0.056, 0.3460±0.056, and 0.03370±0.052 at 3, 6, and 12 months postoperatively (P=0.0005. Complications were limited to mild hyphemia (one case, mild corneal edema (one case, and mild inflammatory membrane (one case that resolved in the first week after surgery.Conclusion: Canaloplasty combined with clear corneal phacoemulsification and intraocular lens implantation may be a safe and effective procedure to lower IOP in adult patients with OAG and visually significant cataract. Keywords: cataract, glaucoma, phacoemulsification

  5. Bidirectional cross metathesis and ring-closing metathesis/ring opening of a C2-symmetric building block: a strategy for the synthesis of decanolide natural products

    Directory of Open Access Journals (Sweden)

    Bernd Schmidt

    2013-11-01

    Full Text Available Starting from the conveniently available ex-chiral pool building block (R,R-hexa-1,5-diene-3,4-diol, the ten-membered ring lactones stagonolide E and curvulide A were synthesized using a bidirectional olefin-metathesis functionalization of the terminal double bonds. Key steps are (i a site-selective cross metathesis, (ii a highly diastereoselective extended tethered RCM to furnish a (Z,E-configured dienyl carboxylic acid and (iii a Ru–lipase-catalyzed dynamic kinetic resolution to establish the desired configuration at C9. Ring closure was accomplished by macrolactonization. Curvulide A was synthesized from stagonolide E through Sharpless epoxidation.

  6. Bidirectional cross metathesis and ring-closing metathesis/ring opening of a C 2-symmetric building block: a strategy for the synthesis of decanolide natural products.

    Science.gov (United States)

    Schmidt, Bernd; Kunz, Oliver

    2013-01-01

    Starting from the conveniently available ex-chiral pool building block (R,R)-hexa-1,5-diene-3,4-diol, the ten-membered ring lactones stagonolide E and curvulide A were synthesized using a bidirectional olefin-metathesis functionalization of the terminal double bonds. Key steps are (i) a site-selective cross metathesis, (ii) a highly diastereoselective extended tethered RCM to furnish a (Z,E)-configured dienyl carboxylic acid and (iii) a Ru-lipase-catalyzed dynamic kinetic resolution to establish the desired configuration at C9. Ring closure was accomplished by macrolactonization. Curvulide A was synthesized from stagonolide E through Sharpless epoxidation.

  7. Synthesis of first row transition metal carboxylate complexes by ring ...

    Indian Academy of Sciences (India)

    tion of pyromellitic dianhydride with methanol and ring opening of pyromellitic dianhydride takes place. The corresponding carboxylate complex formed dur- ing the process can be crystallised by adding biden- tate nitrogen donor ligands such as 1,10-phenanthroline or 2,2 - bipyridine.20 From the reaction with 1,10-.

  8. Alternative loop rings

    CERN Document Server

    Goodaire, EG; Polcino Milies, C

    1996-01-01

    For the past ten years, alternative loop rings have intrigued mathematicians from a wide cross-section of modern algebra. As a consequence, the theory of alternative loop rings has grown tremendously. One of the main developments is the complete characterization of loops which have an alternative but not associative, loop ring. Furthermore, there is a very close relationship between the algebraic structures of loop rings and of group rings over 2-groups. Another major topic of research is the study of the unit loop of the integral loop ring. Here the interaction between loop rings and group ri

  9. Primitivity and weak distributivity in near rings and matrix near rings

    International Nuclear Information System (INIS)

    Abbasi, S.J.

    1993-08-01

    This paper shows the structure of matrix near ring constructed over a weakly distributive and primative near ring. It is proved that a weakly distributive primitive near ring is a ring and the matrix near rings constructed over it is also a bag. (author). 14 refs

  10. Ring Current Response to Different Storm Drivers. Van Allen Probes and Cluster Observations.

    Science.gov (United States)

    Bingham, S.; Mouikis, C.; Kistler, L. M.; Spence, H. E.; Gkioulidou, M.; Claudepierre, S. G.; Farrugia, C. J.

    2015-12-01

    The ring current responds differently to the different solar and interplanetary storm drivers such as coronal mass injections, (CME's), co-rotating interaction regions (CIR's), high-speed streamers and other structures. The resulting changes in the ring current particle pressure change the global magnetic field, which affects the transport of the radiation belts. In order to determine the field changes during a storm it is necessary to understand the transport, sources and losses of the particles that contribute to the ring current. The source population of the storm time ring current is the night side plasma sheet. However, it is not clear how these convecting particles affect the storm time ring current pressure development. We use Van Allen Probes and Cluster observations together with the Volland-Stern and dipole magnetic field models to determine the contribution in the ring current pressure of the plasma sheet particles convecting from the night side that are on open drift paths, during the storm evolution. We compare storms that are related to different interplanetary drivers, CME and CIR, as observed at different local times.

  11. Nonlinear joint angle control for artificially stimulated muscle

    NARCIS (Netherlands)

    Veltink, Petrus H.; Chizeck, Howard J.; Crago, Patrick E.; El-Bialy, Ahmed

    1992-01-01

    Designs of both open- and closed-loop controllers of electrically stimulated muscle that explicitly depend on a nonlinear mathematical model of muscle input-output properties are presented and evaluated. The muscle model consists of three factors: a muscle activation dynamics factor, an angle-torque

  12. Comparison of two ring artefact removal filters used for neutron tomography reconstruction

    International Nuclear Information System (INIS)

    Vontobel, P.

    2007-01-01

    Full text of publication follows: The reduction of ring artefacts in transmission tomography reconstruction, by filtering sino-grams, is a common practice for most radiation modalities. Using simulated and measured neutron transmission data, an analysis of two ring artefact suppression schemes is given. The choice of the ring filtering parameters has to take the noise characteristics of the measured raw projection data into account. Introduction The appearance of ring artefacts in transmission tomography data is quite common. They are due to deficiencies in the measured projections and show as vertical lines in the sinogram representation of all projections of a single slice. A vertical line in the sinogram is due to a single pixel or a group of n pixels on the detector, which is less or more sensitive than the average pixel and shows even after flat-field correction. Most annoying ring artefacts are due to partly dead pixels, which cannot be identified easily on the projection images. Their effect only show in the sinogram or later on the reconstructed slice images. Therefore ring artefact mitigation starts with the analysis of sinogram images or analysis of reconstructed slices. Analysis of two ring filtering algorithms: The first ring filtering method sums first sinogram rows (i.e. over all angles) and divides it by the number of rows (ave) and generate a smoothed version of this sum (smoothing width 3,5,7,9 pixels). The difference diff = ave - smooth(ave) is then subtracted from each row. This is a very simple and efficient correction scheme. The second method relies on morphological filtering the sinogram i.e. using a combination of a morphological 'Top hat' and a 'Bot hat' operation on the data. A filtering threshold is determined depending on the number of detected lines in the sinogram. Summary and conclusion: Using simulated an measured neutron transmission data two ring filtering algorithms are evaluated. A careful choice of filtering parameters is

  13. Commissioning of the Cryogenic Plant for the Cryogenic Storage Ring (CSR) at Heidelberg

    CERN Document Server

    von Hahn, R; Grieser, M; Haberstroh, C; Kaiser, D; Lange, M; Laux, F; Menk, S; Orlov, D A; Repnow, R; Sieber, T; Quack, H; Varju, J; Wolf A

    2009-01-01

    At the Max-Planck-Institute for Nuclear Physics in Heidelberg a next generation electrostatic storage ring for low velocity atomic and molecular ion beams is under construction. In contrast to existing electrostatic storage rings, the Cryogenic Storage Ring CSR will be cooled down to temperatures below 2 K. Thus acting as a large cryopump it will provide long storage times and, in addition, open a new field of quantum state controlled molecular physics due to a low heat radiation background from space-like environment. A concept for cooling the storage ring has been developed and is presently tested by means of a linear trap as a prototype with a length of 1/10 of the planned ring. A commercial refrigerator with 21 W at 2 K has been successfully commissioned and was connected to the prototype. This paper presents the status of the cryogenic plant after the commissioning and one year of operation.

  14. Efficacy and safety of combination therapy with latanoprost after a change in therapeutic regimen from timolol to brinzolamide in Japanese adult patients with primary open-angle glaucoma and ocular hypertension: open, non-randomized 12-week study

    Directory of Open Access Journals (Sweden)

    Shusaku Ishikawa

    2008-09-01

    Full Text Available Shusaku Ishikawa1, Yoshimi Nakamura1, Yuko Nakamura1, Hiroshi Sakai1, Shoichi Sawaguchi1, Kazuo Terashima2, Makoto Kanno2, Hidetoshi Yamashita21Department of Ophthalmology, University of the Ryukyus Faculty of Medicine, Okinawa, Japan; 2Department of Ophthalmology and Visual Science, Yamagata University Faculty of Medicine, Yamagata, JapanPurpose: To compare the efficacy of brinzolamide in Japanese patients with primary open-angle glaucoma (POAG or ocular hypertension (OH after a change from timolol in combination therapy with latanoprost.Methods: A 12-week, prospective, open-label, comparative study was performed in 20 patients [11 males and 9 females, mean age of 64.5 ± 11.0 (SDy] with POAG or OH treated with both latanoprost once daily and timolol 0.5% twice daily. During the study brinzolamide was substituted for timolol. Intraocular pressure (IOP was measured at baseline, 4, 8, and 12 weeks. Blood pressure (BP, pulse rate (PR, and adverse events were also recorded.Results: IOPs at baseline, 4, 8, and 12 weeks were 18.6 ± 2.1 mmHg, 17.8 ± 2.6 mmHg, 17.4 ± 2.5 mmHg, and 17.3 ± 3.5 mmHg, respectively. IOP reduction at 4 and 8 weeks was statistically significant (p < 0.05. The PR was significantly increased at 12 weeks (p < 0.01, but BP was not significantly affected. Four ocular adverse events were noted, but all were mild and transient.Conclusions: Substituting brinzolamide 1% for timolol 0.5% in combination therapy with latanoprost 0.005% demonstrated significant IOP reduction with improvement in PR with POAG or OH. Combination therapy using latanoprost and brinzolamide may be recommended for better IOP control with fewer systemic adverse events.Keywords: open-angle glaucoma, brinzolamide/latanprost combination therapy, timolol/latanoprost combination therapy, intraocular pressure

  15. Change in Visual Field Progression Following Treatment Escalation in Primary Open-angle Glaucoma.

    Science.gov (United States)

    Aptel, Florent; Bron, Alain M; Lachkar, Yves; Schweitzer, Cédric

    2017-10-01

    To evaluate the effect of treatment escalation on the rate of visual field progression in patients with primary open-angle glaucoma (POAG). Multicenter database study. We reviewed the electronic records of 171 patients with POAG under medical hypotensive treatment who underwent 5 consecutive visits 6 months apart before and after medical treatment escalation or additive laser trabeculoplasty. We calculated the rate of visual field progression (mean deviation change per year) before and after treatment escalation. The mean duration of follow-up was 5.1±0.5 years and the mean number of visual field examinations was 10.2±0.2. In 139 eyes with medical treatment escalation, the rate of progression was significantly reduced [from -0.57 to -0.29 dB/y; P=0.022; intraocular pressure (IOP) reduction 11.1%]. In detail, the rate of progression was significantly reduced after escalation from mono to dual therapy, dual to triple therapy, and from mono to triple therapy (-0.35 to -0.24 dB/y, P=0.018; -1.01 to -0.48 dB/y, P=0.038; -1.04 to -0.35 dB/y, P=0.020, respectively). In 32 eyes with additive laser trabeculoplasty, the rate of progression was significantly reduced (-0.60 to -0.24 dB/y; P=0.014; IOP reduction 9.4%). Medical treatment escalation or additive laser trabeculoplasty significantly reduced the rate of visual field progression in POAG. Larger IOP reduction has a greater probability of reducing glaucoma progression.

  16. Evidence for Break-Up of Clumps in Dynamically Stirred Regions of Saturn's Rings

    Science.gov (United States)

    Colwell, J. E.; Sega, D. N.; Jerousek, R. G.; Cooney, J. H.; Esposito, L. W.

    2017-12-01

    Stellar occultations of Saturn's rings observed by the Cassini Ultraviolet Imaging Spectrograph (UVIS) High Speed Photometer (HSP) record stellar brightness seen through the rings as photon counts that are described by Poisson counting statistics in the absence of intervening ring material. The variance in the data increases above counting statistics due to the discrete sizes of the ring particles, with larger particles leading to a larger variance at a given optical depth. We take advantage of the high spatial resolution and multiple viewing geometries of the UVIS occultations to study variations in particle size near and within strongly perturbed regions of Saturn's A ring, in particular the strong first order Lindblad resonances with Janus and the Mimas 5:3 Lindblad resonance and inner vertical resonance. The variance shows changes in the area-weighted particle size between peaks and troughs in the density waves as well as an overall decrease in particle size in the broad "halo" regions that bracket the strong Janus Lindblad resonances in the A ring. In addition we see a decrease in particle size at the location of the Mimas 5:3 bending wave wavetrain itself, and an increase in optical depth at the location of the wave when viewed from high elevation angles out of the ring plane. Taken together, these observations suggest that clumps of particles, perhaps the ubiquitous A ring self-gravity wakes, are disaggregated in the bending wave, even though standard bending wave theory does not predict enhanced collision velocities. We also examine the skewness, a higher order moment of the occultation data, that is diagnostic of asymmetries in the particle size distribution. We use Monte Carlo simulations of occultations to match the first three moments of the data (the signal mean, or equivalently the optical depth, the variance, and the skewness) to illustrate differences in ring particle size in these perturbed regions.

  17. Magnetic field drift shell splitting: Cause of unusual dayside particle pitch angle distributions during storms and substorms

    International Nuclear Information System (INIS)

    Sibeck, D.G.; McEntire, R.W.; Lui, A.T.Y.; Lopez, R.E.; Krimigis, S.M.

    1987-01-01

    We present a magnetic field drift shell--splitting model for the unusual butterfly and head-and-shoulder energetic (E>25 keV) particle pitch angle distributions (PADs) which appear deep within the dayside magnetosphere during the course of storms and substorms. Drift shell splitting separates the high and low pitch angle particles in nightside injections as they move to the dayside magnetosphere, so that the higher pitch angle particles move radially away from Earth. Consequently, butterfly PADs with a surplus of low pitch angle particles form on the inner edge of the injection, but head-and-shoulder PADs with a surplus of high pitch angle particles from on the outer edge. A similar process removes high pitch angle particles from the inner dayside magnetosphere during storms, leaving the remaining lower pitch angle particles to form butterfly PADs on the inner edge of the ring current. A detailed case and statistical study of CCE/MEPA observations, as well as a review of previous work, shows most examples of unusual PADs to be consistent with the model. copyright American Geophysical Union 1987

  18. Brain-Derived Neurotrophic Factor in Patients with Primary Open-Angle Glaucoma and Age-related Cataract.

    Science.gov (United States)

    Shpak, Alexander A; Guekht, Alla B; Druzhkova, Tatiana A; Kozlova, Ksenia I; Gulyaeva, Natalia V

    2018-02-01

    To study brain-derived neurotrophic factor (BDNF) content in aqueous humor (AH), lacrimal fluid (LF), and blood serum (BS) in patients with age-related cataract and primary open-angle glaucoma (POAG). BDNF was studied in 57 patients with age-related cataract, 55 patients with POAG combined with cataract, and 29 healthy controls (one eye in each person). AH was sampled during cataract surgery. The levels of BDNF in LF and BS did not differ in cataract patients and controls. The concentration of BDNF (pg/mL) in patients with POAG and cataract was lower than in cataract patients in AH (35.2 ± 14.2 vs. 54.6 ± 29.6, P early POAG and relatively increased in the next stages of the disease, inversely correlating with visual field index (Pearson's correlation coefficient r = -0.404, P = 0.002) and average retinal nerve fiber layer thickness (r = -0.322, P = 0.018). BDNF contents in LF and BS were also the lowest in early POAG. BDNF in AH strongly correlated with its content in LF (r = 0.66, P early POAG and relative increase in the next stages of the disease. A strong correlation exists between BDNF contents in AH and LF.

  19. Long-term efficacy and safety of ExPress implantation for treatment of open angle glaucoma

    Directory of Open Access Journals (Sweden)

    Geun Young Lee

    2017-09-01

    Full Text Available AIM: To compare the long-term efficacy and safety of ExPress implantation and standard trabeculectomy in patients with primary open angle glaucoma (POAG. METHODS: In this retrospective study, we compared 17 eyes treated by ExPress implantation with 23 eyes treated by trabeculectomy. Efficacy was assessed according to the relevant intraocular pressure (IOP values and success rates during the first year of follow-up. Postoperative corneal endothelial cell loss was also compared. RESULTS: The number of antiglaucoma medications and the IOP reduction were similar between the 2 groups during the follow-up period. Although the mean IOP was similar, the IOP-fluctuation rate during the early postoperative period was significantly lower in the ExPress group than in the trabeculectomy group (P=0.038. A Kaplan-Meier survival curve analysis showed no significant success-rate difference between the groups (P=0.810. The corneal endothelial cell loss rate, moreover, was significantly lower in the ExPress group (P=0.05. CONCLUSION: ExPress implantation compared with trabeculectomy showed similar IOP-reduction and success rates along with lower IOP fluctuation and endothelial cell loss rates. For this reason, it can be considered to be the treatment of choice for patients with advanced glaucoma or low corneal endothelial cell density.

  20. Long-term efficacy and safety of ExPress implantation for treatment of open angle glaucoma.

    Science.gov (United States)

    Lee, Geun Young; Lee, Chong Eun; Lee, Kyoo Won; Seo, Sam

    2017-01-01

    To compare the long-term efficacy and safety of ExPress implantation and standard trabeculectomy in patients with primary open angle glaucoma (POAG). In this retrospective study, we compared 17 eyes treated by ExPress implantation with 23 eyes treated by trabeculectomy. Efficacy was assessed according to the relevant intraocular pressure (IOP) values and success rates during the first year of follow-up. Postoperative corneal endothelial cell loss was also compared. The number of antiglaucoma medications and the IOP reduction were similar between the 2 groups during the follow-up period. Although the mean IOP was similar, the IOP-fluctuation rate during the early postoperative period was significantly lower in the ExPress group than in the trabeculectomy group ( P =0.038). A Kaplan-Meier survival curve analysis showed no significant success-rate difference between the groups ( P =0.810). The corneal endothelial cell loss rate, moreover, was significantly lower in the ExPress group ( P =0.05). ExPress implantation compared with trabeculectomy showed similar IOP-reduction and success rates along with lower IOP fluctuation and endothelial cell loss rates. For this reason, it can be considered to be the treatment of choice for patients with advanced glaucoma or low corneal endothelial cell density.

  1. Relationship between progression of visual field defect and intraocular pressure in primary open-angle glaucoma.

    Science.gov (United States)

    Naito, Tomoko; Yoshikawa, Keiji; Mizoue, Shiro; Nanno, Mami; Kimura, Tairo; Suzumura, Hirotaka; Shiraga, Fumio

    2015-01-01

    To analyze the relationship between intraocular pressure (IOP) and the progression of visual field defects in Japanese primary open-angle glaucoma (POAG) and normal-tension glaucoma (NTG) patients. The subjects of the study were patients undergoing treatment for POAG or NTG who had performed visual field tests at least ten times with a Humphrey field analyzer (Swedish interactive thresholding algorithm standard, C30-2 program). The progression of visual field defects was defined by a significantly negative value of the mean deviation slope at the final visual field test during the follow-up period. The relationships between the progression of visual field defects and IOP, as well as other clinical factors, were retrospectively analyzed. A total of 156 eyes of 156 patients were included in the analysis. Significant progression of visual field defects was observed in 70 eyes of 70 patients (44.9%), while no significant progression was evident in 86 eyes of 86 patients (55.1%). The eyes with visual field defect progression had significantly lower baseline IOP (Pfield defect progression than in eyes without (Pfield defects. In NTG, IOP management should take into account not only achieving the target IOP, but also minimizing the fluctuation of IOP during follow-up period.

  2. Long-term efficacy and safety of ExPress implantation for treatment of open angle glaucoma

    Science.gov (United States)

    Lee, Geun Young; Lee, Chong Eun; Lee, Kyoo Won; Seo, Sam

    2017-01-01

    AIM To compare the long-term efficacy and safety of ExPress implantation and standard trabeculectomy in patients with primary open angle glaucoma (POAG). METHODS In this retrospective study, we compared 17 eyes treated by ExPress implantation with 23 eyes treated by trabeculectomy. Efficacy was assessed according to the relevant intraocular pressure (IOP) values and success rates during the first year of follow-up. Postoperative corneal endothelial cell loss was also compared. RESULTS The number of antiglaucoma medications and the IOP reduction were similar between the 2 groups during the follow-up period. Although the mean IOP was similar, the IOP-fluctuation rate during the early postoperative period was significantly lower in the ExPress group than in the trabeculectomy group (P=0.038). A Kaplan-Meier survival curve analysis showed no significant success-rate difference between the groups (P=0.810). The corneal endothelial cell loss rate, moreover, was significantly lower in the ExPress group (P=0.05). CONCLUSION ExPress implantation compared with trabeculectomy showed similar IOP-reduction and success rates along with lower IOP fluctuation and endothelial cell loss rates. For this reason, it can be considered to be the treatment of choice for patients with advanced glaucoma or low corneal endothelial cell density. PMID:28944196

  3. Angle resolved characterization of nanostructured and conventionally textured silicon solar cells

    DEFF Research Database (Denmark)

    Davidsen, Rasmus Schmidt; Ormstrup, Jeppe; Ommen, Martin Lind

    2015-01-01

    current, open circuit voltage, fill factor (FF) and power conversion efficiency are each measured as function of the relative incident angle between the solar cell and the light source. The relative incident angle is varied from 0° to 90° in steps of 10° in orthogonal axes, such that each solar cell......We report angle resolved characterization of nanostructured and conventionally textured silicon solar cells. The nanostructured solar cells are realized through a single step, mask-less, scalable reactive ion etching (RIE) texturing of the surface. Photovoltaic properties including short circuit...

  4. Ray-tracing studies for a whole-viewing-angle retro-reflector

    International Nuclear Information System (INIS)

    Yang, B.; Friedsam, H.

    1999-01-01

    The APS Survey and Alignment team uses LEICA laser trackers for the majority of their alignment tasks. These instruments utilize several different retro-reflectors for tracking the path of the laser interferometer. Currently in use are open-air comer cubes with an acceptance angle of ±20 deg C, comer cube prisms with an acceptance angle of ±50 deg C, and a Cat's eye with an acceptance angle of ±60 deg C. Best measurement results can be achieved by using an open-air comer cube that eliminates the need for the laser beam to travel through a different medium before it returns to the instrument detector. However, the trade off is a small acceptance angle. In order to overcome the limitations of the small acceptance angles, Takatsuji et al. have proposed the creation of a full-viewing-angle retro-reflector. Based on the notion that the radius R 1 of a common Cat's eye is proportional to R 2 , one can write: R 1 = (n-1)R 2 In the case that n, the refractive index of glass, equals 2, the radii R 1 and R 2 are identical, and one can create a solid sphere Cat's eye. This design has the advantages that no adhesives are used to bond the two hemispheres together, misalignments between the hemispheres are not an issue, and most importantly, larger acceptance angles are possible. This paper shows the results of our ray tracing calculations characterizing the geometrical optics. In Section 2 we derived the analytical expressions for choosing the index of refraction n of a glass sphere based on the specifications of the reflected beam. We also provided an approximation for calculating the minimum radius of a reflector sphere based on efficiency considerations. Finally, in section 3, the analytically derived results were confirmed in a design study for a Cat's eye. (authors)

  5. Electric currents induced by twisted light in Quantum Rings.

    Science.gov (United States)

    Quinteiro, G F; Berakdar, J

    2009-10-26

    We theoretically investigate the generation of electric currents in quantum rings resulting from the optical excitation with twisted light. Our model describes the kinetics of electrons in a two-band model of a semiconductor-based mesoscopic quantum ring coupled to light having orbital angular momentum (twisted light). We find the analytical solution, which exhibits a "circular" photon-drag effect and an induced magnetization, suggesting that this system is the circular analog of that of a bulk semiconductor excited by plane waves. For realistic values of the electric field and material parameters, the computed electric current can be as large as microA; from an applied perspective, this opens new possibilities to the optical control of the magnetization in semiconductors.

  6. Medical versus surgical interventions for open angle glaucoma.

    Science.gov (United States)

    Burr, Jennifer; Azuara-Blanco, Augusto; Avenell, Alison; Tuulonen, Anja

    2012-09-12

    Open angle glaucoma (OAG) is a common cause of blindness. To assess the effects of medication compared with initial surgery in adults with OAG. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2012, Issue 7), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to August 2012), EMBASE (January 1980 to August 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to August 2012), Biosciences Information Service (BIOSIS) (January 1969 to August 2012), Cumulative Index to Nursing and Allied Health Literature (CINAHL) (January 1937 to August 2012), OpenGrey (System for Information on Grey Literature in Europe) (www.opengrey.eu/), Zetoc, the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 1 August 2012. The National Research Register (NRR) was last searched in 2007 after which the database was archived. We also checked the reference lists of articles and contacted researchers in the field. We included randomised controlled trials (RCTs) comparing medications with surgery in adults with OAG. Two authors independently assessed trial quality and extracted data. We contacted study authors for missing information. Four trials involving 888 participants with previously untreated OAG were included. Surgery was Scheie's procedure in one trial and trabeculectomy in three trials. In three trials, primary medication was usually pilocarpine, in one trial it was a beta-blocker.The most recent trial included participants with on average mild OAG. At five years, the risk of progressive visual field loss, based on a three unit change of a composite visual field score, was not

  7. Interaction of ring dark solitons with ring impurities in Bose-Einstein condensates

    International Nuclear Information System (INIS)

    Xue Jukui

    2005-01-01

    The interaction of ring dark solitons/vortexes with the ring-shaped repulsive and attractive impurities in two-dimensional Bose-Einstein condensates is investigated numerically. Very rich interaction phenomena are obtained, i.e., not only the interaction between the ring soliton and the impurity, but also the interaction between vortexes and the impurity. The interaction characters, i.e., snaking of ring soliton, quasitrapping or reflection of ring soliton and vortexes by the impurity, strongly depend on initial ring soliton velocity, impurity strength, initial position of ring soliton and impurity. The numerical results also reveal that ring dark solitons/vortexes can be trapped and dragged by an adiabatically moving attractive ring impurity

  8. Angle-dependent bandgap engineering in gated graphene superlattices

    Energy Technology Data Exchange (ETDEWEB)

    García-Cervantes, H.; Sotolongo-Costa, O. [Centro de Investigación en Ciencias, IICBA, Universidad Autónoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, 62209 Cuernavaca, Morelos, México (Mexico); Gaggero-Sager, L. M. [CIICAp, IICBA, Universidad Autónoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, 62209 Cuernavaca, Morelos, México (Mexico); Naumis, G. G. [Instituto Física, Depto. de Física-Química, Universidad Nacional Autónoma de México (UNAM). Apdo. Postal 20-364, 01000, México D.F., México (Mexico); Rodríguez-Vargas, I., E-mail: isaac@fisica.uaz.edu.mx [Centro de Investigación en Ciencias, IICBA, Universidad Autónoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, 62209 Cuernavaca, Morelos, México (Mexico); Unidad Académica de Física, Universidad Autónoma de Zacatecas, Calzada Solidaridad Esquina Con Paseo La Bufa S/N, 98060 Zacatecas, Zac., México (Mexico)

    2016-03-15

    Graphene Superlattices (GSs) have attracted a lot of attention due to its peculiar properties as well as its possible technological implications. Among these characteristics we can mention: the extra Dirac points in the dispersion relation and the highly anisotropic propagation of the charge carriers. However, despite the intense research that is carried out in GSs, so far there is no report about the angular dependence of the Transmission Gap (TG) in GSs. Here, we report the dependence of TG as a function of the angle of the incident Dirac electrons in a rather simple Electrostatic GS (EGS). Our results show that the angular dependence of the TG is intricate, since for moderated angles the dependence is parabolic, while for large angles an exponential dependence is registered. We also find that the TG can be modulated from meV to eV, by changing the structural parameters of the GS. These characteristics open the possibility for an angle-dependent bandgap engineering in graphene.

  9. Angle-dependent bandgap engineering in gated graphene superlattices

    International Nuclear Information System (INIS)

    García-Cervantes, H.; Sotolongo-Costa, O.; Gaggero-Sager, L. M.; Naumis, G. G.; Rodríguez-Vargas, I.

    2016-01-01

    Graphene Superlattices (GSs) have attracted a lot of attention due to its peculiar properties as well as its possible technological implications. Among these characteristics we can mention: the extra Dirac points in the dispersion relation and the highly anisotropic propagation of the charge carriers. However, despite the intense research that is carried out in GSs, so far there is no report about the angular dependence of the Transmission Gap (TG) in GSs. Here, we report the dependence of TG as a function of the angle of the incident Dirac electrons in a rather simple Electrostatic GS (EGS). Our results show that the angular dependence of the TG is intricate, since for moderated angles the dependence is parabolic, while for large angles an exponential dependence is registered. We also find that the TG can be modulated from meV to eV, by changing the structural parameters of the GS. These characteristics open the possibility for an angle-dependent bandgap engineering in graphene.

  10. Storage Rings

    International Nuclear Information System (INIS)

    Fischer, W.

    2010-01-01

    Storage rings are circular machines that store particle beams at a constant energy. Beams are stored in rings without acceleration for a number of reasons (Tab. 1). Storage rings are used in high-energy, nuclear, atomic, and molecular physics, as well as for experiments in chemistry, material and life sciences. Parameters for storage rings such as particle species, energy, beam intensity, beam size, and store time vary widely depending on the application. The beam must be injected into a storage ring but may not be extracted (Fig. 1). Accelerator rings such as synchrotrons are used as storage rings before and after acceleration. Particles stored in rings include electrons and positrons; muons; protons and anti-protons; neutrons; light and heavy, positive and negative, atomic ions of various charge states; molecular and cluster ions, and neutral polar molecules. Spin polarized beams of electrons, positrons, and protons were stored. The kinetic energy of the stored particles ranges from 10 -6 eV to 3.5 x 10 12 eV (LHC, 7 x 10 12 eV planned), the number of stored particles from one (ESR) to 1015 (ISR). To store beam in rings requires bending (dipoles) and transverse focusing (quadrupoles). Higher order multipoles are used to correct chromatic aberrations, to suppress instabilities, and to compensate for nonlinear field errors of dipoles and quadrupoles. Magnetic multipole functions can be combined in magnets. Beams are stored bunched with radio frequency systems, and unbunched. The magnetic lattice and radio frequency system are designed to ensure the stability of transverse and longitudinal motion. New technologies allow for better storage rings. With strong focusing the beam pipe dimensions became much smaller than previously possible. For a given circumference superconducting magnets make higher energies possible, and superconducting radio frequency systems allow for efficient replenishment of synchrotron radiation losses of large current electron or positron beams

  11. Design of a 4.8-m ring for inverse Compton scattering x-ray source

    Directory of Open Access Journals (Sweden)

    H. S. Xu

    2014-07-01

    Full Text Available In this paper we present the design of a 50 MeV compact electron storage ring with 4.8-meter circumference for the Tsinghua Thomson scattering x-ray source. The ring consists of four dipole magnets with properly adjusted bending radii and edge angles for both horizontal and vertical focusing, and a pair of quadrupole magnets used to adjust the horizontal damping partition number. We find that the dynamic aperture of compact storage rings depends essentially on the intrinsic nonlinearity of the dipole magnets with small bending radius. Hamiltonian dynamics is found to agree well with results from numerical particle tracking. We develop a self-consistent method to estimate the equilibrium beam parameters in the presence of the intrabeam scattering, synchrotron radiation damping, quantum excitation, and residual gas scattering. We also optimize the rf parameters for achieving a maximum x-ray flux.

  12. Novel ring resonator-based integrated photonic beamformer for broadband phased array receive antennas - part 2: experimental prototype

    NARCIS (Netherlands)

    Zhuang, L.; Roeloffzen, C.G.H.; Meijerink, Arjan; Burla, M.; Marpaung, D.A.I.; Leinse, Arne; Hoekman, M.; Heideman, Rene; van Etten, Wim

    2010-01-01

    An experimental prototype is presented that illustrates the implementation aspects and feasibility of the novel ring resonator-based optical beamformer concept that has been developed and analyzed in Part I of this paper . This concept can be used for seamless control of the reception angle in

  13. Open-Midplane Dipoles for a Muon Collider

    International Nuclear Information System (INIS)

    Weggel, R.; Gupta, R.; Kolonko, J.; Scanlan, R.; Cline, D.; Ding, X.; Anerella, M.; Kirk, H.; Palmer, B.; Schmalzle, J.

    2011-01-01

    For a muon collider with copious decay particles in the plane of the storage ring, open-midplane dipoles (OMD) may be preferable to tungsten-shielded cosine-theta dipoles of large aperture. The OMD should have its midplane completely free of material, so as to dodge the radiation from decaying muons. Analysis funded by a Phase I SBIR suggests that a field of 10-20 T should be feasible, with homogeneity of 1 x 10 -4 and energy deposition low enough for conduction cooling to 4.2 K helium. If funded, a Phase II SBIR would refine the analysis and build and test a proof-of-principle magnet. A Phase I SBIR has advanced the feasibility of open-midplane dipoles for the storage ring of a muon collider. A proposed Phase II SBIR would refine these predictions of stresses, deformations, field quality and energy deposition. Design optimizations would continue, leading to the fabrication and test, for the first time, of a proof-of-principle dipole of truly open-midplane design.

  14. Genome-wide linkage scan for primary open angle glaucoma: influences of ancestry and age at diagnosis.

    Directory of Open Access Journals (Sweden)

    Kristy R Crooks

    Full Text Available Primary open-angle glaucoma (POAG is the most common form of glaucoma and one of the leading causes of vision loss worldwide. The genetic etiology of POAG is complex and poorly understood. The purpose of this work is to identify genomic regions of interest linked to POAG. This study is the largest genetic linkage study of POAG performed to date: genomic DNA samples from 786 subjects (538 Caucasian ancestry, 248 African ancestry were genotyped using either the Illumina GoldenGate Linkage 4 Panel or the Illumina Infinium Human Linkage-12 Panel. A total of 5233 SNPs was analyzed in 134 multiplex POAG families (89 Caucasian ancestry, 45 African ancestry. Parametric and non-parametric linkage analyses were performed on the overall dataset and within race-specific datasets (Caucasian ancestry and African ancestry. Ordered subset analysis was used to stratify the data on the basis of age of glaucoma diagnosis. Novel linkage regions were identified on chromosomes 1 and 20, and two previously described loci-GLC1D on chromosome 8 and GLC1I on chromosome 15--were replicated. These data will prove valuable in the context of interpreting results from genome-wide association studies for POAG.

  15. Decompositions of the polyhedral product functor with applications to moment-angle complexes and related spaces.

    Science.gov (United States)

    Bahri, A; Bendersky, M; Cohen, F R; Gitler, S

    2009-07-28

    This article gives a natural decomposition of the suspension of a generalized moment-angle complex or partial product space which arises as the polyhedral product functor described below. The introduction and application of the smash product moment-angle complex provides a precise identification of the stable homotopy type of the values of the polyhedral product functor. One direct consequence is an analysis of the associated cohomology. For the special case of the complements of certain subspace arrangements, the geometrical decomposition implies the homological decomposition in earlier work of others as described below. Because the splitting is geometric, an analogous homological decomposition for a generalized moment-angle complex applies for any homology theory. Implied, therefore, is a decomposition for the Stanley-Reisner ring of a finite simplicial complex, and natural generalizations.

  16. Open Source Initiative Powers Real-Time Data Streams

    Science.gov (United States)

    2014-01-01

    Under an SBIR contract with Dryden Flight Research Center, Creare Inc. developed a data collection tool called the Ring Buffered Network Bus. The technology has now been released under an open source license and is hosted by the Open Source DataTurbine Initiative. DataTurbine allows anyone to stream live data from sensors, labs, cameras, ocean buoys, cell phones, and more.

  17. Reproducibility of Scleral Spur Identification and Angle Measurements Using Fourier Domain Anterior Segment Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Ricardo J. Cumba

    2012-01-01

    Full Text Available Purpose. To evaluate intraobserver and interobserver agreement in locating the scleral spur landmark (SSL and anterior chamber angle measurements obtained using Fourier Domain Anterior Segment Optical Coherence Tomography (ASOCT images. Methods. Two independent, masked observers (SR and AZC identified SSLs on ASOCT images from 31 eyes with open and nonopen angles. A third independent reader, NPB, adjudicated SSL placement if identifications differed by more than 80 μm. Nine months later, SR reidentified SSLs. Intraobserver and interobserver agreement in SSL placement, trabecular-iris space area (TISA750, and angle opening distance (AOD750 were calculated. Results. In 84% of quadrants, SR’s SSL placements during 2 sessions were within 80 μm in both the X- and Y-axes, and in 77% of quadrants, SR and AZC were within 80 μm in both axes. In adjudicated images, 90% of all quadrants were within 80 μm, 88% in nonopen-angle eyes, and 92% in open-angle eyes. The intraobserver and interobserver correlation coefficients (with and without adjudication were above 0.9 for TISA750 and AOD750 for all quadrants. Conclusions. Reproducible identification of the SSL from images obtained with FD-ASOCT is possible. The ability to identify the SSL allows reproducible measurement of the anterior chamber angle using TISA750 and AOD750.

  18. Energy and pitch-angle dispersions of LLBL/cusp ions seen at middle altitudes: predictions by the open magnetosphere model

    Directory of Open Access Journals (Sweden)

    M. Lockwood

    1997-12-01

    Full Text Available Numerical simulations are presented of the ion distribution functions seen by middle-altitude spacecraft in the low-latitude boundary layer (LLBL and cusp regions when reconnection is, or has recently been, taking place at the equatorial magnetopause. From the evolution of the distribution function with time elapsed since the field line was opened, both the observed energy/observation-time and pitch-angle/energy dispersions are well reproduced. Distribution functions showing a mixture of magnetosheath and magnetospheric ions, often thought to be a signature of the LLBL, are found on newly opened field lines as a natural consequence of the magnetopause effects on the ions and their flight times. In addition, it is shown that the extent of the source region of the magnetosheath ions that are detected by a satellite is a function of the sensitivity of the ion instrument . If the instrument one-count level is high (and/or solar-wind densities are low, the cusp ion precipitation detected comes from a localised region of the mid-latitude magnetopause (around the magnetic cusp, even though the reconnection takes place at the equatorial magnetopause. However, if the instrument sensitivity is high enough, then ions injected from a large segment of the dayside magnetosphere (in the relevant hemisphere will be detected in the cusp. Ion precipitation classed as LLBL is shown to arise from the low-latitude magnetopause, irrespective of the instrument sensitivity. Adoption of threshold flux definitions has the same effect as instrument sensitivity in artificially restricting the apparent source regionKey words. Low-latitude boundary layer · Cusp regions · Open magnetosphere model · Mid-altitudes

  19. Comparison of Newly Diagnosed Ocular Hypertension and Open-Angle Glaucoma: Ocular Variables, Risk Factors, and Disease Severity

    Directory of Open Access Journals (Sweden)

    Yvonne M. Buys

    2012-01-01

    Full Text Available Purpose. To describe the distribution of ocular variables, risk factors, and disease severity in newly diagnosed ocular hypertension (OH or open-angle glaucoma (OAG. Methods. Eligible subjects underwent a complete history and examination. Adjusted odds ratios (ORs and 95% confidence intervals (CIs obtained from multiple logistic regression models were used to compare OAG to OH and advanced to early/moderate OAG. Results. 405 subjects were enrolled: 292 (72.1% with OAG and 113 (27.9% with OH. 51.7% had early, 27.1% moderate, and 20.9% advanced OAG. The OR for OAG versus OH was 8.19 (P<0.0001 for disc notch, 5.36 (P<0.0001 for abnormal visual field, 1.45 (P=0.001 for worsening mean deviation, 1.91 (P<0.0001 for increased cupping, 1.03 for increased age (P=0.030, and 0.36 (P=0.010 for smoking. Conclusions. Increased age was a risk for OAG, and smoking decreased the risk of OAG compared to OH. Almost half of the OAG subjects had moderate/advanced disease at diagnosis.

  20. Rings in drugs.

    Science.gov (United States)

    Taylor, Richard D; MacCoss, Malcolm; Lawson, Alastair D G

    2014-07-24

    We have analyzed the rings, ring systems, and frameworks in drugs listed in the FDA Orange Book to understand the frequency, timelines, molecular property space, and the application of these rings in different therapeutic areas and target classes. This analysis shows that there are only 351 ring systems and 1197 frameworks in drugs that came onto the market before 2013. Furthermore, on average six new ring systems enter drug space each year and approximately 28% of new drugs contain a new ring system. Moreover, it is very unusual for a drug to contain more than one new ring system and the majority of the most frequently used ring systems (83%) were first used in drugs developed prior to 1983. These observations give insight into the chemical novelty of drugs and potentially efficient ways to assess compound libraries and develop compounds from hit identification to lead optimization and beyond.