WorldWideScience

Sample records for rikkyo university triga-mk-2 reactor

  1. Operating experience of TRIGA MK-II Research Reactor in Bangladesh

    International Nuclear Information System (INIS)

    Mannan, M.A.; Ahmed, K.

    1992-01-01

    A 3 MW TRIGA MK II Research Reactor was installed in Bangladesh in 1986. The reactor is being utilized for research, training and for production of radioisotopes. Recently two faults were detected, one in the Emergency Core Cooling System and the other in the Primary Coolant Loop, which hindered the operation of the reactor partially. The faults were investigated by a team of local experts. Results of analyses of possible initiating events of the faults and the remedial steps are briefly discussed in the paper. (author)

  2. PUSPATI TRIGA Reactor

    International Nuclear Information System (INIS)

    Masood, Z.

    2016-01-01

    The PUSPATI TRIGA Reactor is the only research reactor in Malaysia. This 1 MW TRIGA Mk II reactor first reached criticality on 28 June 1982 and is located at the Malaysian Nuclear Agency premise in Bangi, Malaysia. This reactor has been mainly utilised for research, training and education and isotope production. Over the years several systems have been refurbished or modernised to overcome ageing and obsolescence problems. Major achievements and milestones will also be elaborated in this paper. (author)

  3. Annual report of the research results with Rikkyo University's joint-use reactor etc. for fiscal 1974

    International Nuclear Information System (INIS)

    1975-01-01

    The results of research works by universities with Rikkyo University's joint-use reactor and RCNST's (Research Center for Nuclear Science and Technology) instruments for fiscal 1974 are described. Comprising the areas of activation analysis (in such as earth science, biology and environmental science), hot atom chemistry, etc., the results are presented in individual summaries. (Mori, K.)

  4. Fabrication and testing of a 4-node micro-pocket fission detector array for the Kansas State University TRIGA Mk. II research nuclear reactor

    Science.gov (United States)

    Reichenberger, Michael A.; Nichols, Daniel M.; Stevenson, Sarah R.; Swope, Tanner M.; Hilger, Caden W.; Unruh, Troy C.; McGregor, Douglas S.; Roberts, Jeremy A.

    2017-08-01

    Advancements in nuclear reactor core modeling and computational capability have encouraged further development of in-core neutron sensors. Micro-Pocket Fission Detectors (MPFDs) have been fabricated and tested previously, but successful testing of these prior detectors was limited to single-node operation with specialized designs. Described in this work is a modular, four-node MPFD array fabricated and tested at Kansas State University (KSU). The four sensor nodes were equally spaced to span the length of the fuel-region of the KSU TRIGA Mk. II research nuclear reactor core. The encapsulated array was filled with argon gas, serving as an ionization medium in the small cavities of the MPFDs. The unified design improved device ruggedness and simplified construction over previous designs. A 0.315-in. (8-mm) penetration in the upper grid plate of the KSU TRIGA Mk. II research nuclear reactor was used to deploy the array between fuel elements in the core. The MPFD array was coupled to an electronic support system which has been developed to support pulse-mode operation. Neutron-induced pulses were observed on all four sensor channels. Stable device operation was confirmed by testing under steady-state reactor conditions. Each of the four sensors in the array responded to changes in reactor power between 10 kWth and full power (750 kWth). Reactor power transients were observed in real-time including positive transients with periods of 5, 15, and 30 s. Finally, manual reactor power oscillations were observed in real-time.

  5. Report on application results of the nuclear reactor in Atomic Energy Research Laboratory, Rikkyo University. April 1994 - March 1995

    International Nuclear Information System (INIS)

    1995-01-01

    This report is on researching action state, application state, management state, and others of 1994 fiscal year at the Atomic Energy Research Laboratory, Rikkyo University. The experimental reactor has been used for the studies such as application of neutron radioactivity analysis to multi fields, application of fission and alpha track method to age determination and metallurgy, hot atom chemistry, neutron radiation effect on semiconductors and others, nuclear data measurement, organism, materials and products using neutron radiography, and development and application to inspection of radiation detectors such as neutron detector. This report was a report shown as a shape of research results of actions of the researchers. And, another report of colaborate research results using the Rikkyo University reactor was also published from the Atomic Energy Center, the University of Tokyo begun since April, 1974. (G.K.)

  6. Arkansas Tech University TRIGA nuclear reactor

    International Nuclear Information System (INIS)

    Sankoorikal, J.; Culp, R.; Hamm, J.; Elliott, D.; Hodgson, L.; Apple, S.

    1990-01-01

    This paper describes the TRIGA nuclear reactor (ATUTR) proposed for construction on the campus of Arkansas Tech University in Russellville, Arkansas. The reactor will be part of the Center for Energy Studies located at Arkansas Tech University. The reactor has a steady state power level of 250 kW and can be pulsed with a maximum reactivity insertion of $2.0. Experience gained in dismantling and transporting some of the components from Michigan State University, and the storage of these components will be presented. The reactor will be used for education, training, and research. (author)

  7. Effective cross sections of U-235 and Au in a TRIGA-type reactor core

    International Nuclear Information System (INIS)

    Harasawa, S.; Auu, G.A.

    1992-01-01

    The dependence of effective cross sections of gold and uranium for neutron spectrum in Rikkyo University Reactor (TRIGA Mark- II, RUR) fuel cell was studied using computer calculations. The dependence of thermal neutron spectrum with temperature was also investigated. The effective cross section of gold in water of the fuel cell at 32degC was 90.3 barn and the fission cross section of U-235, 483 barn. These two values are similar to the cross sections for neutron energy of 0.034 eV. (author)

  8. Oregon State University TRIGA Reactor annual report

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, T.V.; Johnson, A.G.; Bennett, S.L.; Ringle, J.C.

    1979-08-31

    The use of the Oregon State University TRIGA Reactor during the year ending June 30, 1979, is summarized. Environmental and radiation protection data related to reactor operation and effluents are included.

  9. Oregon State University TRIGA Reactor annual report

    International Nuclear Information System (INIS)

    Anderson, T.V.; Johnson, A.G.; Bennett, S.L.; Ringle, J.C.

    1979-01-01

    The use of the Oregon State University TRIGA Reactor during the year ending June 30, 1979, is summarized. Environmental and radiation protection data related to reactor operation and effluents are included

  10. Progress of decommissioning of Rikkyo reactor in FY2014

    International Nuclear Information System (INIS)

    Suzuki, M.; Kato, M.; Tanzawa, T.; Kawaguchi, K.; Terasawa, T.; Yamada, Shigeru; Nakai, Masaru

    2015-01-01

    Institute for Atomic Energy, Rikkyo University, applied in 2012 for changes in the decommissioning plan toward the abolition of the reactor facilities, and received approval. It promoted the decommissioning work of the research reactors in a plan for two years from 2012, conducted the removal of the structure installed in the reactor tank and storage management measures, and implemented the function stop of the disposal facility of liquid waste and the removal of part of them. These procedures achieved the safe storage condition of core internal structure / equipment with relatively high radioactivity due to neutron irradiation. In addition, the maintenance management of partial facilities and equipment that had been maintained in operational conditions had come to be unnecessary. Based on these results, the implementation plan for decommissioning scheduled for 2015-2016 was prepared. The contents of main works are as follows: (1) dismantling and removal of disposal facilities for liquid waste and storage management of subsequently generated radioactive waste in the reactor building control area, (2) storage management of radioactive solid waste of solid waste storage facilities in the reactor building control area, (3) dismantling and removal of solid waste storage facilities that become unnecessary, and (4) release of part of the controlled area associated with the above actions. (A.O.)

  11. Planning and implementation of Istanbul Technical University TRIGA research reactor program

    International Nuclear Information System (INIS)

    Aybers, N.; Yavuz, H.; Bayulken, A.

    1982-01-01

    The Istanbul Technical University TRIGA Research Reactor at the Institute for Nuclear Energy, which went critical on March 11, 1979 is basically a pulsing type TRIGA Mark - II reactor. Completion of the ITU-TRR contributed to broaden the role of the Institute for Nuclear Energy of the Technical University in Istanbul in the nuclear field by providing for the first time adequate on-campus experimental facilities for nuclear engineering studies to ITU students. The research program which is currently under planning at ITU-NEE encompasses: a) Neutron activation analysis studies by techniques and applications to chemistry, mining, materials research, archaeological and biomedical studies; b) applications of Radioisotopes; c) Radiography with reactor neutron beams; d) Radiation Pulsing

  12. TRIGA reactor main systems

    International Nuclear Information System (INIS)

    Boeck, H.; Villa, M.

    2007-01-01

    This module describes the main systems of low power (<2 MW) and higher power (≥2 MW) TRIGA reactors. The most significant difference between the two is that forced reactor cooling and an emergency core cooling system are generally required for the higher power TRIGA reactors. However, those TRIGA reactors that are designed to be operated above 3 MW also use a TRIGA fuel that is specifically designed for those higher power outputs (3 to 14 MW). Typical values are given for the respective systems although each TRIGA facility will have unique characteristics that may only be determined by the experienced facility operators. Due to the inherent wide scope of these research reactor facilities construction and missions, this training module covers those systems found at most operating TRIGA reactor facilities but may also discuss non-standard equipment that was found to be operationally useful although not necessarily required. (author)

  13. Neutronics modeling of TRIGA reactor at the University of Utah using agent, KENO6 and MCNP5 codes

    International Nuclear Information System (INIS)

    Yang, X.; Xiao, S.; Choe, D.; Jevremovic, T.

    2010-01-01

    The TRIGA reactor at the University of Utah is modelled in 2D using the AGENT state-of-the-art methodology based on the Method of Characteristics (MOC) and R-function theory supporting detailed reactor analysis of reactor geometries of any type. The TRIGA reactor is also modelled using KENO6 and MCNP5 for comparison. The spatial flux and reaction rates distribution are visualized by AGENT graphics support. All methodologies are in use in to study the effect of different fuel configurations in developing practical educational exercises for students studying reactor physics. At the University of Utah we train graduate and undergraduate students in obtaining the Nuclear Regulatory Commission license in operating the TRIGA reactor. The computational models as developed are in support of these extensive training classes and in helping students visualize the reactor core characteristics in regard to neutron transport under various operational conditions. Additionally, the TRIGA reactor is under the consideration for power uprate; this fleet of computational tools once benchmarked against real measurements will provide us with validated 3D simulation models for simulating operating conditions of TRIGA. (author)

  14. Ten years of TRIGA reactor research at the University of Texas

    International Nuclear Information System (INIS)

    O'Kelly, Sean

    2002-01-01

    The 1 MW TRIGA Research Reactor at the Nuclear Engineering Teaching Laboratory is the second TRIGA at the University of Texas at Austin (UT). A small (10 kW-1963, 250 kW-1968) TRIGA Mark I was housed in the basement of the Engineering Building until is was shutdown and decommissioned in 1989. The new TRIGA Mark II with a licensed power of 1.1 MW reached initial criticality in 1992. Prior to 1990, reactor research at UT usually consisted of projects requiring neutron activation analysis (NAA) but the step up to a much larger reactor with neutron beam capability required additional personnel to build the neutron research program. The TCNS is currently used to perform Prompt Gamma Activation Analysis to determine hydrogen and boron concentrations of various composite materials. The early 1990s was a very active period for neutron beam projects at the NETL. In addition to the TCNS, a real-time neutron radiography facility (NIF) and a high-resolution neutron depth profiling facility (NDP) were installed in two separate beam ports. The NDP facility was most recently used to investigate alpha damage on stainless steel in support of the U.S. Nuclear Weapons Stewardship programs. In 1999, a sapphire beam filter was installed in the NDP system to reduce the fast neutron flux at the sample location. A collaborative effort was started in 1997 between UT-Austin and the University of Texas at Arlington to build a reactor-based, low-energy positron beam (TIPS). The limited success in obtaining funding has placed the project on hold. The Nuclear and Radiation Engineering Program has grown rapidly and effectively doubled in size over the past 5 years but years of low nuclear research funding, an overall stagnation in the U.S. nuclear power industry and a persuasive public distrust of nuclear energy has caused a precipitous decline in many programs. Recently, the U.S. DOE has encouraged University Research Reactors (URR) in the U.S. to collaborate closely together by forming URR

  15. University of Arizona TRIGA reactor. Annual utilization report, 1984-1985

    International Nuclear Information System (INIS)

    Nelson, G.W.

    1986-01-01

    This is the annual report for the University of Arizona TRIGA Reactor under Contract No. DE-AC02-76ER02096 covering the period July 1, 1984 through June 30, 1985, including the 1984-85 Academic Year. The purpose of this report is to document the facility usage which is possible because of DOE support under the contract. The reactor is operated under License R-52 with the United States Nuclear Regulatory Commission

  16. TRIGA reactor characteristics

    International Nuclear Information System (INIS)

    Boeck, H.; Villa, M.

    2007-01-01

    This module describes the general design, characteristics and parameters of TRIGA reactors and fuels. It is recommended that most of this information should be incorporated into any reactor operator training program and, in many cases, the facility Safety Analysis Report. It is oriented to teach the basics of the physics and mechanical design of the TRIGA fuel as well as its unique operational characteristics and the differences between TRIGA fuels and others more traditional reactor fuels. (nevyjel)

  17. Use of the Oregon State University TRIGA reactor for education and training

    International Nuclear Information System (INIS)

    Dodd, B.

    1989-01-01

    This paper summarizes the recent use of the Oregon State University TRIGA Reactor (OSTR) for education and training. In particular, data covering the last 5 yr are presented, which cover education through formal university classes, theses, public information, and school programs. Training is covered by presenting data on domestic and foreign reactor operator training, health physics training, and neutron activation analysis training. While education and training only occupy ∼16% of the OSTR's total use time, nevertheless, this is an important mission of all nonpower reactors that cannot be performed effectively in any other way

  18. Assessment of gold flux monitor at irradiation facilities of MINT TRIGA MK II reactor

    International Nuclear Information System (INIS)

    Wee Boon Siong; Abdul Khalik Wood; Mohd Suhaimi Hamzah; Shamsiah Abdul Rahman; Md Suhaimi Elias; Nazaratul Ashifa Abd Salim

    2005-01-01

    Neutron source of MINTs TRIGA MK II reactor has been used for activation analysis for many years and neutron flux plays important role in activation of samples at various positions. Currently, two irradiation facilities namely the pneumatic transfer system and rotary rack are available to cater for short and long lived irradiation. Neutron flux variation for both irradiation facilities have been determined using gold wire and gold solution as flux monitor. However, the use of gold wire as flux monitor is costlier if compared to gold solution. The results from analysis of certified reference materials showed that gold solution as flux monitors yield satisfactory results and proved to safe cost on the purchasing of gold wire. Further experiment on self-shielding effects of gold solution at various concentrations has been carried out. This study is crucial in providing vital information on the suitable concentration for gold solution as flux monitor. In the near future, gold solution flux monitor will be applied for routine analysis and hence to improve the capability of the laboratory on neutron activation analysis. (Author)

  19. Operational experience with the TRIGA reactor of the University of Pavia

    International Nuclear Information System (INIS)

    Borio di Tigliole, A.; Alloni, D.; Cagnazzo, M.; Coniglio, M.; Lana, F.; Losi, A.; Magrotti, G.; Manera, S.; Marchetti, F.; Pappalardo, P.; Prata, M.; Salvini, A.; Scian, G.; Vinciguerra, G.

    2008-01-01

    The TRIGA Mark II research reactor of the University of Pavia is in operation since 1965. The annual operational time at nominal power (250 kW) is in the range of 300 - 400 hours depending upon the time schedule of some experiments and research activities. The reactor is mainly used for NAA activities and BNCT research. Few tens of hours per year are dedicated also to electronic devices irradiation and student training courses. Few homemade upgrading of the reactor were realized in the past two years: components of the secondary/tertiary cooling circuit were substituted and a new radiation area monitoring system was installed. Also the Instrumentation and Control (I and C) system was almost completely refurbished. The presentation describes the major extraordinary maintenance activities implemented and the status of main reactor systems: - The I and C System: complete substitution, channel-by-channel without changing the operating and safety logics; - Tertiary and secondary water-cooling circuits: complete substitution of the tertiary water-cooling circuit and partial substitution of the components of the secondary water-cooling circuit; - Reactor Building Air Filtering and Ventilation System: installation of a computerized air filtering and ventilation system; - Radiation Area Monitoring System: new system based on a commercial micro-computer and an home-made software developed on Lab-View platform. The system is made of a network of different instruments coupled, trough a serial bus line RS232, with a data acquisition station; - Fuel Elements: at the moment, the core is made of 48 Aluminium clad and 34 SST clad TRIGA fuel elements controlled periodically for their elongation and/or bowing. All components and systems undergo ordinary maintenance according to the Technical Prescriptions and to the 'Good Practice Procedures'. In summary, the TRIGA reactor of the University of Pavia shows a very good technical state and, at the moment, there are no political or

  20. Evaluation of TRIGA Mark II reactor in Turkey

    International Nuclear Information System (INIS)

    Bilge, Ali Nezihi

    1990-01-01

    There are two research reactors in Turkey and one of them is the university Triga Mark II reactor which was in service since 1979 both for education and industrial application purposes. The main aim of this paper is to evaluate the spectrum of the services carried by Turkish Triga Mark II reactor. In this work, statistical distribution of the graduate works and applications, by using Triga Mark II reactor is examined and evaluated. In addition to this, technical and scientific uses of this above mentioned reactor are also investigated. It was already showed that the uses and benefits of this reactor can not be limited. If the sufficient work and service is given, NDT and industrial applications can also be carried economically. (orig.)

  1. Plan of studies on fuel failure detection in Rikkyo Research Reactor

    International Nuclear Information System (INIS)

    Matsuura, T.; Nagahara, T.; Hattori, M.; Kawaguchi, K.

    1987-01-01

    Studies on fuel failure detection in Rikkyo Research Reactor have recently been begun in the following four approaches. (1) Accumulation of the data on the concentration of the short-lived radioactivity originating from FP rare gases contained in the air on the water surface of the reactor tank. (2) Accumulation of the data on the concentration of FP (especially 131 I) in the water of the reactor tank. (3) Design and preparation of a ''sniffer'' by which the location of the failed fuel element can be detected, when some anomaly is found in the above two routine measurements. (4) Design and preparation of a vessel containing a fuel element, which can be useful both for ''sipping'' inspection of the fuel element and for storage of the damaged fuel element. In this paper, an outline of the above approaches and the results of some preliminary experiments are reported. (author)

  2. Studies on fuel failure detection in Rikkyo Research Reactor

    International Nuclear Information System (INIS)

    Matsuura, T.; Hayashi, S.H.; Harasawa, S.; Tomura, K.

    1992-01-01

    Studies on fuel failure detection have been made since 1986 in Rikkyo Research Reactor. One of the methods is the monitoring of the trace concentration of fission products appearing in the air on the surface of the water tank of the reactor. The interested radionuclides here are 89 Rb and 138 Cs, which are the daughter nuclides of the FP rare gas nuclides, 89 Kr and 138 Xe, respectively and have the half lives of 15.2 min and 32.2 min respectively. They are detected on a filter paper attached on a conventional dust sampler, by sucking the air of the surface of the water for 15 ∼ 30 min during reactor operation (100 kW). In this presentation are reported the results of an attempt to increase the sensitivity of detecting these nuclides by introducing nitrogen gas bubbles into the water. The bubbling of the gas increased the sensitivity as much as several times compared with the case without bubbling. These measurements are giving us the 'background' concentration, the order of which is almost unchanged for these several years, --in 10 -6 Bq/cm 3 . The origin of these nuclides is considered to be not from the fuel but from the uranium contained as an impurity in the reactor material in the core. (author)

  3. Ten-year utilization of the Oregon State University TRIGA Reactor (OSTR)

    International Nuclear Information System (INIS)

    Ringle, John C.; Anderson, Terrance V.; Johnson, Arthur G.

    1978-01-01

    The Oregon State University TRIGA Reactor (OSTR) has been used heavily throughout the past ten years to accommodate exclusively university research, teaching, and training efforts. Averages for the past nine years show that the OSTR use time has been as follows: 14% for academic and special training courses; 44% for OSU research projects; 6% for non-OSU research projects; 2% for demonstrations for tours; and 34% for reactor maintenance, calibrations, inspections, etc. The OSTR has operated an average of 25.4 hours per week during this nine-year period. Each year, about 20 academic courses and 30 different research projects use the OSTR. Visitors to the facility average about 1,500 per year. No commercial radiations or services have been performed at the OSTR during this period. Special operator training courses are given at the OSTR at the rate of at least one per year. (author)

  4. Applications of Oregon State University's TRIGA reactor in health physics education

    International Nuclear Information System (INIS)

    Higginbotham, J.F.

    1990-01-01

    The Oregon State University TRIGA reactor (OSTR) is used to support a broad range of traditional academic disciplines, including anthropology, oceanography, geology, physics, nuclear chemistry, and nuclear engineering. However, it also finds extensive application in the somewhat more unique area of health physics education and research. This paper summarizes these health physics applications and briefly describes how the OSTR makes important educational contributions to the field of health physics

  5. Radiological monitoring related to the operation of PUSPATI's Triga Reactor

    International Nuclear Information System (INIS)

    Fatimah Mohamad Amin; Mohamad Yusof Mohamad Ali; Lau How Mooi; Idris Besar.

    1983-01-01

    Reactor operation is one of the main activities carried out at the Tun Ismail Atomic Research Centre (PUSPATI) which requires radiological monitoring. This paper describes the programme for radiological monitoring which is related to the operation of the 1 MW Triga MK II research reactor which was commissioned in July, 1982. This programme includes monitoring of the radiation and contamination levels of the reactor and its associated facilities and environmental monitoring of PUSPATI's site and its environs. The data presented in this paper covers the period between 1982 to 1983 which includes both the pre-operational and operational phases of the monitoring programme. (author)

  6. Simulation development for TRIGA reactor

    International Nuclear Information System (INIS)

    Handoyo, D.

    1997-01-01

    A simulator of the dynamic of TRIGA reactor has been made. this simulator is meant to study the reactor kinetic behavior and for operator training to more assure the safety and the reliability of the real operation of TRIGA reactor. the simulator consists of PC (Personal Computer) for processing the calculation of reactivity, neutron flux, period, ect and control panel for regulating the input data such as the change of power range, control rod position as well as cooling flow rate. the result will be displayed on screen monitor of personal computer as given in the real control room of TRIGA reactor. the output of simulator will be verified by comparing with measurement result in the real TRIGA MARK II reactor of Musashi institute of technology. for the change of reactivity of 0.3, 0.5 and 0.7 the reactor power and fuel temperature between the simulator and measurements are comparable

  7. Study of a new automatic reactor power control for the TRIGA Mark II reactor at University of Pavia

    Energy Technology Data Exchange (ETDEWEB)

    Borio Di Tigliole, A.; Magrotti, G. [Laboratorio Energia Nucleare Applicata (L.E.N.A.), University of Pavia, Via Aselli 41, 27100 (Italy); Cammi, A.; Memoli, V. [Politecnico di Milano, Department of Energy, Nuclear Engineering Division (CeSNEF), Via Ponzio 34/3, 20133 Milano (Italy); Gadan, M. A. [Instrumentation and Control Department, National Atomic Energy Comission of Argentina, University of Pavia (Italy)

    2009-07-01

    The installation of a new Instrumentation and Control (IC) system for the TRIGA Mark-II reactor at University of Pavia has recently been completed in order to assure a safe and continuous reactor operation for the future. The intervention involved nearly the whole IC system and required a channel-by-channel component substitution. One of the most sensitive part of the intervention concerned the Automatic Reactor Power Controller (ARPC) which permits to keep the reactor at an operator-selected power level acting on the control rod devoted to the fine regulation of system reactivity. This controller installed can be set up using different control logics: currently the system is working in relay mode. The main goal of the work presented in this paper is to set up a Proportional-Integral-Derivative (PID) configuration of the new controller installed on the TRIGA reactor of Pavia so as to optimize the response to system perturbations. The analysis have shown that a continuous PID offers generally better results than the relay mode which causes power oscillations with an amplitude of 3% of the nominal power

  8. 2nd world TRIGA users conference. Conference volume

    International Nuclear Information System (INIS)

    2004-01-01

    This conference was organized by the Atomic Institute of the Austrian Universities (University of Technology Vienna), it was devoted to present results in the operation of TRIGA research reactors. The main general topics were: a) reactor operation experience, b)neutron and solid state physics, c) radiochemistry and activation analysis, d) medical applications (boron neutron capture therapy, labeled compounds), e) reactor related experiments and calculations, f) waste management and decommissioning of TRIGA reactors. (nevyjel)

  9. 2nd world TRIGA users conference. Conference volume

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    This conference was organized by the Atomic Institute of the Austrian Universities (University of Technology Vienna), it was devoted to present results in the operation of TRIGA research reactors. The main general topics were: a) reactor operation experience, b)neutron and solid state physics, c) radiochemistry and activation analysis, d) medical applications (boron neutron capture therapy, labeled compounds), e) reactor related experiments and calculations, f) waste management and decommissioning of TRIGA reactors. (nevyjel)

  10. Opportunities for TRIGA reactors in neutron radiography

    International Nuclear Information System (INIS)

    Barton, John P.

    1978-01-01

    In this country the two most recent installations of TRIGA reactors have both been for neutron radiography, one at HEDL and the other at ANL. Meanwhile, a major portion of the commercial neutron radiography is performed on a TRIGA fueled reactor at Aerotest. Each of these installations has different primary objectives and some comparative observations can be drawn. Another interesting comparison is between the TRIGA reactors for neutron radiography and other small reactors that are being installed for this purpose such as the MIRENE slow pulse reactors in France, a U-233 fueled reactor for neutron radiography in India and the L88 solution reactor in Denmark. At Monsanto Laboratory, in Ohio, a subcritical reactor based on MTR-type fuel has recently been purchased for neutron radiography. Such systems, when driven by a Van de Graaff neutron source, will be compared with the standard TRIGA reactor. Future demands on TRIGA or competitive systems for neutron radiography are likely to include the pulsing capability of the reactor, and also the extraction of cold neutron beams and resonance energy beams. Experiments recently performed on the Oregon State TRIGA Reactor provide information in each of these categories. A point of particular current concern is a comparison made between the resonance energy beam intensity extracted from the edge of the TRIGA core and from a slot which penetrated to the center of the TREAT reactor. These results indicate that by using such slots on a TRIGA, resonance energy intensities could be extracted that are much higher than previously predicted. (author)

  11. Neutron beam utilization at the TRIGA Mark II reactor Vienna

    International Nuclear Information System (INIS)

    Villa, M.; Boeck, H.; Ismail, S.; Koerner, S.; Baron, M.; Hainbuchner, M.; Badurek, G.; Buchelt, R.J.

    1999-01-01

    A review is given about the research activities around the 250 kw TRIGA reactor Vienna, which are adequate to other neutron sources of comparable or bigger size. The topics selected for presentation range from neutron radiography, materials irradiation, neutron small-angle scattering, neutron activation analysis, neutron polarization to neutron interferometry. It is the aim of this presentation to stimulate programs for more efficient use around TRIGA research reactors with neutron flux densities of 1013 cm-2a-1 at the center of the reactor core. We briefly describe the experimental facilities installed at the 250 kw TRIGA reactor of the Austrian Universities in Vienna and present a great part of the current research activities performed with them. We believe that most of the techniques and experiments presented here are adequate for implementation to other reactors of similar or even higher power. Those technologies which require extremely specialized know-how not generally available at every research Inst.e will not be treated here or are just mentioned without any further details.(author)

  12. History, Development and Future of TRIGA Research Reactors

    International Nuclear Information System (INIS)

    2016-01-01

    Due to its particular fuel design and resulting enhanced inherent safety features, TRIGA reactors (Training, Research, Isotopes, General Atomics) constitute a ‘class of their own’ among the large variety of research reactors built world-wide. This publication summarizes in a single document the information on the past and present of TRIGA research reactors and presents an outlook in view of potential issues to be solved by TRIGA operating organizations in the near future. It covers the historical development and basic TRIGA characteristics, followed by utilization, fuel conversion and ageing management of TRIGA research reactors. It continues with issues and challenges, introduction to the global TRIGA research reactor network and concludes with future perspectives. The publication is complemented with a CD-ROM to illustrate the historical developments of TRIGA research reactors through individual facility examples and experiences

  13. [2. European] TRIGA owners' conference. Papers and abstracts

    International Nuclear Information System (INIS)

    1972-01-01

    The Second European TRIGA Owners' Conference was held in Pavia, Italy, September 1972. The meeting was organized by the University of Pavia Applied Nuclear Energy Laboratory (L.E.N.A.). Sixty-two attendees representing 12 TRIGA reactor centers in Europe, South America, and the United States were present at the Conference. The main areas of discussions were: Reactor operation and maintenance experience; Research programs and TRIGA technology development

  14. [2. European] TRIGA owners' conference. Papers and abstracts

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1972-07-01

    The Second European TRIGA Owners' Conference was held in Pavia, Italy, September 1972. The meeting was organized by the University of Pavia Applied Nuclear Energy Laboratory (L.E.N.A.). Sixty-two attendees representing 12 TRIGA reactor centers in Europe, South America, and the United States were present at the Conference. The main areas of discussions were: Reactor operation and maintenance experience; Research programs and TRIGA technology development.

  15. RIA Analysis of Unprotected TRIGA Reactor

    Directory of Open Access Journals (Sweden)

    M.H. Altaf

    2017-07-01

    Full Text Available An RIA (reactivity initiated accident analysis has been carried out for the TRIGA Mark II research reactor considering both step and ramp reactivity ranges within 0.5 % dk/k (< $1 to 2.0 % dk/k (>$2. The insertion time was set at 10 s. Based on the fact that a reactor becomes unprotected if scram does not work at the event of danger, to define unprotected conditions, the time to actuate scram (trip was taken as close to total simulation time. In this long duration of scram inactivity, it is obtained from the present analysis that the reactor remained safe to up to 1.8 % dk/k ($2.57 for step reactivity and 1.99 % dk/k ($2.84 for ramp reactivity. In addition to negative temperature coefficient of reativity, probably the longer time of reactivity insertion keeps TRIGA safe even at larger magnitudes of reactivity during unprotected reactor transients. Coupled point kinetics, neutronics, and thermal hydraulics code EUREKA-2/R has been utilized for this work. It appears that EUREKA-2/RR predicts the sequence of unprotected transient scenario of TRIGA core with good approximation and the results will definitely be helpful for the reactor operators.

  16. Preliminary neutronic design of TRIGA Mark II Reactor

    International Nuclear Information System (INIS)

    Sarikaya, B.; Tombakoglu, M.; Cecen, Y.; Kadiroglu, O. K.

    2001-01-01

    It is very important to analyse the behaviour of the research reactors, since, they play a key role in developing the power reactor technology and radiation applications such as isotope generation for medical treatments. In this study, the neutronic behaviour of the TRIGA MARK II reactor, owned and operated by Istanbul Technical University is analysed by using the SCALE code system. In the analysis, in order to overcome the disadvantages of special TRIGA codes, such as TRIGAP, the SCALE code system is chosen to perform the calculations. TRIGAP and similar codes have limited geometrical (one-dimensional geometry) and cross sectional options (two-group calculations), however, SCALE has the capability of wider range of geometrical modelling capability (three-dimensional modelling is possible) and multi-group calculations are possible

  17. NRF TRIGA packaging

    International Nuclear Information System (INIS)

    Clements, M.D.

    1995-11-01

    Training Reactor Isotopes, General Atomics (TRIGA reg-sign) Reactors are in use at four US Department of Energy (DOE) complex facilities and at least 23 university, commercial, or government facilities. The development of the Neutron Radiography Facility (NRF) TRIGA packaging system began in October 1993. The Hanford Site NRF is being shut down and requires an operationally user-friendly transportation and storage packaging system for removal of the TRIGA fuel elements. The NRF TRIGA packaging system is designed to remotely remove the fuel from the reactor and transport the fuel to interim storage (up to 50 years) on the Hanford Site. The packaging system consists of a cask and an overpack. The overpack is used only for transport and is not necessary for storage. Based upon the cask's small size and light weight, small TRIGA reactors will find it versatile for numerous refueling and fuel storage needs. The NRF TRIGA packaging design also provides the basis for developing a certifiable and economical packaging system for other TRIGA reactor facilities. The small size of the NRF TRIGA cask also accommodates placing the cask into a larger certified packaging for offsite transport. The Westinghouse Hanford Company NRF TRIGA packaging, as described herein can serve other DOE sites for their onsite use, and the design can be adapted to serve university reactor facilities, handling a variety of fuel payloads

  18. Fuel burnup analysis of the TRIGA Mark II reactor at the University of Pavia

    International Nuclear Information System (INIS)

    Chiesa, Davide; Clemenza, Massimiliano; Pozzi, Stefano; Previtali, Ezio; Sisti, Monica; Alloni, Daniele; Magrotti, Giovanni; Manera, Sergio; Prata, Michele; Salvini, Andrea; Cammi, Antonio; Zanetti, Matteo; Sartori, Alberto

    2016-01-01

    Highlights: • A fuel evolution model for a TRIGA Mark II reactor has been developed. • Reproduction of nearly 50 years of reactor operation. • The model was used to predict the best reactor reconfiguration. • Reactor life was extended without adding fresh fuel elements. - Abstract: A time evolution model was developed to study fuel burnup for the TRIGA Mark II reactor at the University of Pavia. The results were used to predict the effects of a complete core reconfiguration and the accuracy of this prediction was tested experimentally. We used the Monte Carlo code MCNP5 to reproduce system neutronics in different operating conditions and to analyze neutron fluxes in the reactor core. The software that took care of time evolution, completely designed in-house, used the neutron fluxes obtained by MCNP5 to evaluate fuel consumption. This software was developed specifically to keep into account some features that differentiate low power experimental reactors from those used for power production, such as the daily ON/OFF cycle and the long fuel lifetime. These effects can not be neglected to properly account for neutron poison accumulation. We evaluated the effect of 48 years of reactor operation and predicted a possible new configuration for the reactor core: the objective was to remove some of the fuel elements from the core and to obtain a substantial increase in the Core Excess reactivity value. The evaluation of fuel burnup and the reconfiguration results are presented in this paper.

  19. Dynamics of TRIGA-3 Salazar Reactor

    International Nuclear Information System (INIS)

    Gallardo S, L.F.

    1990-01-01

    The theoretical study of temporal behavior of a nuclear reactor is of great importance, since it allows to know, in advance, the conditions to which a reactor is going to be submitted. The reliability of two computer codes (AIREK-JEN and PLANKIN) designed to reproduce the temporal behavior of nuclear reactors, generally power reactors, when they are applied to reproduce the dynamic behavior of TRIGA-3 Salazar Reactor is analyzed. In the first chapters, the fundamental equations that solve this computer codes are deduced, and also the main characteristics of TRIGA-3 Salazar Reactor and the necessary data to run the programs are presented; later the results obtained with the computer codes and the experimental results reported in the operational logbook of the reactor are compared, with the result that such computer codes are applicable to the temporal study of TRIGA-3 Salazar Reactor. (Author)

  20. Dynamics of TRIGA-3 Salazar Reactor.; Dinamica del Reactor TRIGA Mark III del Centro Nuclear de Mexico.

    Energy Technology Data Exchange (ETDEWEB)

    Gallardo S, L F

    1991-12-31

    The theoretical study of temporal behavior of a nuclear reactor is of great importance, since it allows to know, in advance, the conditions to which a reactor is going to be submitted. The reliability of two computer codes (AIREK-JEN and PLANKIN) designed to reproduce the temporal behavior of nuclear reactors, generally power reactors, when they are applied to reproduce the dynamic behavior of TRIGA-3 Salazar Reactor is analyzed. In the first chapters, the fundamental equations that solve this computer codes are deduced, and also the main characteristics of TRIGA-3 Salazar Reactor and the necessary data to run the programs are presented; later the results obtained with the computer codes and the experimental results reported in the operational logbook of the reactor are compared, with the result that such computer codes are applicable to the temporal study of TRIGA-3 Salazar Reactor. (Author).

  1. Experimental determination of the total isothermal reactivity feedback coefficient for the University of Arizona TRIGA research reactor

    International Nuclear Information System (INIS)

    Spriggs, Gregory D.; Nelson, George W.

    1976-01-01

    An experiment was performed to measure the total isothermal (or bath) feedback coefficient of reactivity for the University of Arizona TRIGA Research Reactor (UARR). It was found that the bath coefficient was temperature-dependent and may be represented by the expression α iso .2634 x 10 -2 + .3428 x 10 -3 T - 2.471 x 10 -5 T 2 + 3.476 x 10 -7 T 3 for the temperature range of 7 C to 43 C. (author)

  2. 78 FR 5840 - Notice of License Termination for University of Illinois Advanced TRIGA Reactor, License No. R-115

    Science.gov (United States)

    2013-01-28

    ... University of Illinois Advanced TRIGA Reactor, License No. R-115 The U.S. Nuclear Regulatory Commission (NRC) is noticing the termination of Facility Operating License No. R-115, for the University of Illinois... Operating License No. R-115 is terminated. The above referenced documents may be examined, and/or copied for...

  3. Modeling the PUSPATI TRIGA Reactor using MCNP code

    International Nuclear Information System (INIS)

    Mohamad Hairie Rabir; Mark Dennis Usang; Naim Syauqi Hamzah; Julia Abdul Karim; Mohd Amin Sharifuldin Salleh

    2012-01-01

    The 1 MW TRIGA MARK II research reactor at Malaysian Nuclear Agency achieved initial criticality on June 28, 1982. The reactor is designed to effectively implement the various fields of basic nuclear research, manpower training, and production of radioisotopes. This paper describes the reactor parameters calculation for the PUSPATI TRIGA REACTOR (RTP); focusing on the application of the developed reactor 3D model for criticality calculation, analysis of power and neutron flux distribution and depletion study of TRIGA fuel. The 3D continuous energy Monte Carlo code MCNP was used to develop a versatile and accurate full model of the TRIGA reactor. The model represents in detailed all important components of the core and shielding with literally no physical approximation. (author)

  4. Characterization of the TRIGA Mark II reactor full-power steady state

    Energy Technology Data Exchange (ETDEWEB)

    Cammi, Antonio, E-mail: antonio.cammi@polimi.it [Politecnico di Milano – Department of Energy, CeSNEF (Enrico Fermi Center for Nuclear Studies), via La Masa 34, 20156 Milano (Italy); Zanetti, Matteo [Politecnico di Milano – Department of Energy, CeSNEF (Enrico Fermi Center for Nuclear Studies), via La Masa 34, 20156 Milano (Italy); Chiesa, Davide; Clemenza, Massimiliano; Pozzi, Stefano; Previtali, Ezio; Sisti, Monica [University of Milano-Bicocca, Physics Department “G. Occhialini” and INFN Section, Piazza dell’Ateneo Nuovo, 20126 Milan (Italy); Magrotti, Giovanni; Prata, Michele; Salvini, Andrea [University of Pavia, Applied Nuclear Energy Laboratory (L.E.N.A.), Via Gaspare Aselli 41, 27100 Pavia (Italy)

    2016-04-15

    Highlights: • Full-power steady state characterization of the TRIGA Mark II reactor. • Monte Carlo and Multiphysics simulation of the TRIGA Mark II reactor. • Sub-cooled boiling effects in the TRIGA Mark II reactor. • Thermal feedback effects in the TRIGA Mark II reactor. • Experimental data based validation. - Abstract: In this paper, the characterization of the full-power steady state of the TRIGA Mark II nuclear reactor at the University of Pavia is achieved by coupling the Monte Carlo (MC) simulation for neutronics with the “Multiphysics” model for thermal-hydraulics. Neutronic analyses have been carried out with a MCNP5 based MC model of the entire reactor system, already validated in fresh fuel and zero-power configurations (in which thermal effects are negligible) and using all available experimental data as a benchmark. In order to describe the full-power reactor configuration, the temperature distribution in the core must be established. To evaluate this, a thermal-hydraulic model has been developed, using the power distribution results from the MC simulation as input. The thermal-hydraulic model is focused on the core active region and takes into account sub-cooled boiling effects present at full reactor power. The obtained temperature distribution is then entered into the MC model and a benchmark analysis is carried out to validate the model in fresh fuel and full-power configurations. An acceptable correspondence between experimental data and simulation results concerning full-power reactor criticality proves the reliability of the adopted methodology of analysis, both from the perspective of neutronics and thermal-hydraulics.

  5. TRIGA reactor health physics considerations

    International Nuclear Information System (INIS)

    Johnson, A.G.

    1970-01-01

    The factors influencing the complexity of a TRIGA health physics program are discussed in details in order to serve as a basis for later consideration of various specific aspects of a typical TRIGA health physics program. The health physics program must be able to provide adequate assistance, control, and safety for individuals ranging from the inexperienced student to the experienced postgraduate researcher. Some of the major aspects discussed are: effluent release and control; reactor area air monitoring; area monitoring; adjacent facilities monitoring; portable instrumentation, personnel monitoring. TRIGA reactors have not been associated with many significant occurrences in the area of health physics, although some operational occurrences have had health physics implications. One specific occurrence at OSU is described involving the detection of non-fission-product radioactive particulates by the continuous air monitor on the reactor top. The studies of this particular situation indicate that most of the particulate activity is coming from the rotating rack and exhausting to the reactor top through the rotating rack loading tube

  6. Over Twenty Years Of Experience In ITU TRIGA MARK-II Reactor

    International Nuclear Information System (INIS)

    Yavuz, Hasbi

    2008-01-01

    I.T.U. TRIGA MARK-II Training and Research Reactor, rated at 250 kW steady-state and 1200 MW pulsing power is the only research and training reactor owned and operated by a university in Turkey. Reactor has been operating since March 11, 1979; therefore the reactor has been operating successfully for more than twenty years. Over the twenty years of operation: - The tangential beam tube was equipped with a neutron radiography facility, which consists of a divergent collimator and exposure room; - A computerized data acquisition system was designed and installed such that all parameters of the reactor, which are observed from the console, could be monitored both in normal and pulse operations; - An electrical power calibration system was built for the thermal power calibration of the reactor; - Publications related with I.T.U. TRIGA MARK-II Training and Research Reactor are listed in Appendix; - Two majors undesired shutdown occurred; - The I.T.U. TRIGA MARK-II Training and Research Reactor is still in operation at the moment. (authors)

  7. TRIGA research reactors with higher power density

    International Nuclear Information System (INIS)

    Whittemore, W.L.

    1994-01-01

    The recent trend in new or upgraded research reactors is to higher power densities (hence higher neutron flux levels) but not necessarily to higher power levels. The TRIGA LEU fuel with burnable poison is available in small diameter fuel rods capable of high power per rod (≅48 kW/rod) with acceptable peak fuel temperatures. The performance of a 10-MW research reactor with a compact core of hexagonal TRIGA fuel clusters has been calculated in detail. With its light water coolant, beryllium and D 2 O reflector regions, this reactor can provide in-core experiments with thermal fluxes in excess of 3 x 10 14 n/cm 2 ·s and fast fluxes (>0.1 MeV) of 2 x 10 14 n/cm 2 ·s. The core centerline thermal neutron flux in the D 2 O reflector is about 2 x 10 14 n/cm 2 ·s and the average core power density is about 230 kW/liter. Using other TRIGA fuel developed for 25-MW test reactors but arranged in hexagonal arrays, power densities in excess of 300 kW/liter are readily available. A core with TRIGA fuel operating at 15-MW and generating such a power density is capable of producing thermal neutron fluxes in a D 2 O reflector of 3 x 10 14 n/cm 2 ·s. A beryllium-filled central region of the core can further enhance the core leakage and hence the neutron flux in the reflector. (author)

  8. Extension of TRIGA reactor capabilities

    International Nuclear Information System (INIS)

    Gietzen, A.J.

    1980-01-01

    The first TRIGA reactor went into operation at 10 kW about 22 years ago. Since that time 55 TRIGAs have been put into operation including steady-state powers up to 14,000 kW and pulsing reactors that pulse to 20,000,000 kW. Five more are under construction and a proposal will soon be submitted for a reactor of 25,000 kW. Along with these increases in power levels (and the corresponding fluxes) the experimental facilities have also been expanded. In addition to the installation of new TRIGA reactors with enhanced capabilities many of the older reactors have been modified and upgraded. Also, a number of reactors originally fueled with plate fuel were converted to TRIGA fuel to take advantage of the improved technical and safety characteristics, including the ability for pulsed operation. In order to accommodate increased power and performance the fuel has undergone considerable evolution. Most of the changes have been in the geometry, enrichment and cladding material. However, more recently further development on the UZrH alloy has been carried out to extend the uranium content up to 45% by weight. This increased U content is necessary to allow the use of less than 20% enrichment in the higher powered reactors while maintaining longer core lifetime. The instrumentation and control system has undergone remarkable improvement as the electronics technology has evolved so rapidly in the last two decades. The information display and the circuitry logic has also undergone improvements for enhanced ease of operation and safety. (author)

  9. The research reactor TRIGA Mainz

    International Nuclear Information System (INIS)

    Hampel, G.; Eberhardt, K.; Trautmann, N.

    2006-01-01

    The TRIGA Mark II reactor at the Institut fuer Kernchemie became first critical on August 3 rd , 1965. It can be operated in the steady state mode with a maximum power of 100 kWth and in the pulse mode with a peak power of 250 MWth. A survey of the research programmes performed at the TRIGA Mainz is given covering applications in basic research as well as applied science in nuclear chemistry and nuclear physics. Furthermore, the reactor is used for neutron activation analysis and for education and training of scientists, teachers, students and technical personal. Important projects for the future of the TRIGA Mainz are the UCN (ultra cold neutrons) experiment, fast chemical separation, medical applications and the use of the NAA as well as the use of the reactor facility for the training of students in the fields of nuclear chemistry, nuclear physics and radiation protection. Taking into account the past and future operation schedule and the typically low burn-up of TRIGA fuel elements (∝4 g U-235/a), the reactor can be operated for at least the next decade taking into account the fresh fuel elements on stock and without changing spent fuels. (orig.)

  10. TRIGA 14 MW Research Reactor Status and Utilization

    International Nuclear Information System (INIS)

    Barbos, D.; Ciocanescu, M.; Paunoiu, C.

    2016-01-01

    Institute for Nuclear Research is the owner of the largest family TRIGA research reactor, TRIGA14 MW research reactor. TRIGA14 MW reactor was designed to be operated with HEU nuclear fuel but now the reactor core was fully converted to LEU nuclear fuel. The full conversion of the core was a necessary step to ensure the continuous operation of the reactor. The core conversion took place gradually, using fuel manufactured in different batches by two qualified suppliers based on the same well qualified technology for TRIGA fuel, including some variability which might lead to a peculiar behaviour under specific conditions of reactor utilization. After the completion of the conversion a modernization program for the reactor systems was initiated in order to achieve two main objectives: safe operation of the reactor and reactor utilization in a competitive environment to satisfy the current and future demands and requirements. The 14 MW TRIGA research reactor operated by the Institute for Nuclear Research in Pitesti, Romania, is a relatively new reactor, commissioned 37 years ago. It is expected to operate for another 15-20 years, sustaining new fuel and testing of materials for future generations of power reactors, supporting radioisotopes production through the development of more efficient new technologies, sustaining research or enhanced safety, extended burn up and verification of new developments concerning nuclear power plants life extension, to sustain neutron application in physics research, thus becoming a centre for instruction and training in the near future. A main objective of the TRIGA14MW research reactor is the testing of nuclear fuel and nuclear material. The TRIGA 14 MW reactor is used for medical and industrial radioisotopes production ( 131 I, 125 I, 192 Ir etc.) and a method for 99 Mo- 99 Tc production from fission is under development. For nuclear materials properties investigation, neutron radiography methods have been developed in the INR. The

  11. Planned Scientific programs around the Triga Mark 2 Reactor

    International Nuclear Information System (INIS)

    Majah, M Ibn.

    2007-01-01

    Full text: Nuclear techniques have been introduced to Morocco since the sixties. After the energy crisis of 1973, Morocco decides to create the National Center for Energy Sciences and Nuclear Techniques (CNESTEN) under the supervision of the Ministry of high Education and Research, with a research commercial and support vocation. CNESTEN is in charge of promoting nuclear application, to act as technical support for the authorities and to prepare the technological basis for nuclear power option. In 1998, CNESTEN started the construction of Nuclear Research Centre. The on going activities cover many sectors : earth and environmental sciences, high energy physics, safety and security, waste management. In 2001, CNESTEN started the construction of a 2MW TRiga Mark 2 Reactor, with the possibility to increase the power to 3 MW. The construction was achieved in January 2007. The operation of the reactor is expected for April 2007. The program of the utilization of the reactor was established with th contribution of the university and with the assistance of IAEA. Some of the experimental set-up installed around the reactor have been designed. CNESTEN has developed cooperation with Nuclear research centres from other countries and is receiving visitors and trainees mainly through the IAEA [fr

  12. Operational Experience with the TRIGA Mark II Reactor of the University of Pavia

    Energy Technology Data Exchange (ETDEWEB)

    Tigliole, A. Borio Di; Alloni, D.; Cagnazzo, M.; Coniglio, M.; Lana, F.; Losi, A.; Magrotti, G.; Manera, S.; Marchetti, F.; Pappalardo, P.; Prata, M.; Provasi, M.C.; Salvini, A.; Scian, G.; Vinciguerra, G. [University of Pavia, Laboratory of Applied Nuclear Energy (L.E.N.A), Via Aselli 41, 27100 Pavia (Italy)

    2011-07-01

    The Laboratory of Applied Nuclear Energy (LENA) is an Interdepartmental Research Centre of the University of Pavia which operates a 250 kW TRIGA Mark II Research Nuclear Reactor, a Cyclotron for the production of radioisotopes and other irradiation facilities. The reactor is in operation since 1965 and many home-made upgrading were realized in the past years in order to assure a continuous operation of the reactor for the future. The annual reactor operational time at nominal power is in the range of 300 - 400 hours depending upon the time schedule of some experiments and research activities. The reactor is mainly used for NAA activities, BNCT research, samples irradiation and training. In specific, few tens of hours of reactor operation per year are dedicated to training courses for University students and for professionals. Besides, the LENA Centre hosts every year more than one thousand high school students in visit. Lately, LENA was certified ISO 9001:2008 for the ''operation and maintenance of the reactor'' and for the ''design and delivery of the irradiation service''. Nowadays the reactor shows a good technical state and, at the moment, there are no political or economical reason to consider the reactor shut-down. (author)

  13. TRIGA reactor owners' seminar. Papers and abstracts

    International Nuclear Information System (INIS)

    1970-01-01

    The TRIGA Reactor Owners' Conference was planned with the aim of bringing together a group of persons interested in the ownership and operation of TRIGA reactors in the hope that an interchange of viewpoints, information, and experience would prove of mutual benefit

  14. Five years of operating the TRIGA Mainz reactor

    International Nuclear Information System (INIS)

    Benedict, Georg

    1970-01-01

    Considerable obstacles had to be surmounted before TRIGA MAINZ, first TRIGA reactor built in Germany, reached initial criticality in 1965. Subsequent five years' operation did not raise any major problems. The facility has proven quite reliable and particularly well suited for the purposes of the nuclear chemistry research program pursued at Mainz University. Extensive use is made of the pulse mode of operation. As a result, fuel elements are obviously somewhat overstressed, even though most pulses performed are of the 1.50 dollar size. Maximum licensed steady state power of 100 kW till now has met the requirements of most experiments. However, efforts are in progress to improve irradiation conditions by increasing the reactor power to 300 kW. (author)

  15. Credible accident analyses for TRIGA and TRIGA-fueled reactors

    International Nuclear Information System (INIS)

    Hawley, S.C.; Kathren, R.L.

    1982-04-01

    Credible accidents were developed and analyzed for TRIGA and TRIGA-fueled reactors. The only potential for offsite exposure appears to be from a fuel-handling accident that, based on highly conservative assumptions, would result in dose equivalents of less than or equal to 1 mrem to the total body from noble gases and less than or equal to 1.2 rem to the thyroid from radioiodines. Credible accidents from excess reactivity insertions, metal-water reactions, lost, misplaced, or inadvertent experiments, core rearrangements, and changes in fuel morphology and ZrH/sub x/ composition are also evaluated, and suggestions for further study provided

  16. History, Development and Future of TRIGA Research Reactors. Companion CD-ROM

    International Nuclear Information System (INIS)

    2016-01-01

    Due to its particular fuel design and resulting enhanced inherent safety features, TRIGA reactors (Training, Research, Isotopes, General Atomics) constitute a ‘class of their own’ among the large variety of research reactors built world-wide. This publication summarizes in a single document the information on the past and present of TRIGA research reactors and presents an outlook in view of potential issues to be solved by TRIGA operating organizations in the near future. It covers the historical development and basic TRIGA characteristics, followed by utilization, fuel conversion and ageing management of TRIGA research reactors. It continues with issues and challenges, introduction to the global TRIGA research reactor network and concludes with future perspectives. This CD-ROM illustrates the historical developments of TRIGA research reactors through individual facility examples and experiences

  17. Computer code for the thermal-hydraulic analysis of ITU TRIGA Mark-II reactor

    International Nuclear Information System (INIS)

    Ustun, G.; Durmayaz, A.

    2002-01-01

    Istanbul Technical University (ITU) TRIGA Mark-II reactor core consists of ninety vertical cylindrical elements located in five rings. Sixty-nine of them are fuel elements. The reactor is operated and cooled with natural convection by pool water, which is also cooled and purified in external coolant circuits by forced convection. This characteristic leads to consider both the natural and forced convection heat transfer in a 'porous-medium analysis'. The safety analysis of the reactor requires a thermal-hydraulic model of the reactor to determine the thermal-hydraulic parameters in each mode of operation. In this study, a computer code cooled TRIGA-PM (TRIGA - Porous Medium) for the thermal-hydraulic analysis of ITU is considered. TRIGA Mark-II reactor code has been developed to obtain velocity, pressure and temperature distributions in the reactor pool as a function of core design parameters and pool configuration. The code is a transient, thermal-hydraulic code and requires geometric and physical modelling parameters. In the model, although the reactor is considered as only porous medium, the other part of the reactor pool is considered partly as continuum and partly as porous medium. COMMIX-1C code is used for the benchmark purpose of TRIGA-PM code. For the normal operating conditions of the reactor, estimations of TRIGA-PM are in good agreement with those of COMMIX-1C. After some more improvements, this code will be employed for the estimation of LOCA scenario, which can not be analyses by COMMIX-1C and the other multi-purpose codes, considering a break at one of the beam tubes of the reactor

  18. 14. U.S. TRIGA users conference. Final program and summary of papers

    International Nuclear Information System (INIS)

    1994-01-01

    The following papers were presented at the Conference: Early Development and Use of the TRIGA Reactor; Results of the MCNP Analysis of 20/20 LEU Fuel for the Oregon State University TRIGA Reactor; Upgradeable 2MW TRIGA Reactor Design for the Morocco Nuclear Energy Center McClellan Nuclear Radiation Center TRIGA Reactor: Four Years of Operations

  19. 14. U.S. TRIGA users conference. Final program and summary of papers

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-07-01

    The following papers were presented at the Conference: Early Development and Use of the TRIGA Reactor; Results of the MCNP Analysis of 20/20 LEU Fuel for the Oregon State University TRIGA Reactor; Upgradeable 2MW TRIGA Reactor Design for the Morocco Nuclear Energy Center McClellan Nuclear Radiation Center TRIGA Reactor: Four Years of Operations.

  20. Preparation for shipment of spent TRIGA fuel elements from the research reactor of the Medical University of Hannover

    International Nuclear Information System (INIS)

    Hampel, Gabriele; Cordes, Harro; Ebbinghaus, Kurt; Haferkamp, Dirk

    1998-01-01

    In the early seventies a research reactor of type TRIGA Mark I was installed in the Department of Nuclear Medicine at the Medical University of Hannover (MHH) for the production of isotopes with short decay times for medical use. Since new production methods have been developed, the reactor has become obsolete and the MHH decided to decommission it. Probably in the second quarter of 1999 all 76 spent TRIGA fuel elements will be shipped to Idaho National Engineering and Environmental Laboratory (INEEL), USA, in one cask of type GNS 16. Due to technical reasons within the MHH a special Mobile Transfer System, which is being developed by the company Noell-KRC, will be used for reloading the fuel elements and transferring them from the reactor to the cask GNS 16. A description of the main components of this system as well as the process for transferring the fuel elements follows. (author)

  1. Verification of MCNP simulation of neutron flux parameters at TRIGA MK II reactor of Malaysia.

    Science.gov (United States)

    Yavar, A R; Khalafi, H; Kasesaz, Y; Sarmani, S; Yahaya, R; Wood, A K; Khoo, K S

    2012-10-01

    A 3-D model for 1 MW TRIGA Mark II research reactor was simulated. Neutron flux parameters were calculated using MCNP-4C code and were compared with experimental results obtained by k(0)-INAA and absolute method. The average values of φ(th),φ(epi), and φ(fast) by MCNP code were (2.19±0.03)×10(12) cm(-2)s(-1), (1.26±0.02)×10(11) cm(-2)s(-1) and (3.33±0.02)×10(10) cm(-2)s(-1), respectively. These average values were consistent with the experimental results obtained by k(0)-INAA. The findings show a good agreement between MCNP code results and experimental results. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. A TRIGA reactor in an industrial laboratory

    International Nuclear Information System (INIS)

    Anders, Oswald U.

    1980-01-01

    The Dow TRIGA Reactor is a well established facility in its industrial environment. It is used extensively for internal Dow projects. The primary use of the TRIGA is as neutron source for NAA. It faces similar technical and organizational challenges as other TRIGA installations and over the years developed its own solutions

  3. Industrial and commercial applications for a Triga reactor

    International Nuclear Information System (INIS)

    Green, D.

    1986-01-01

    The Physics and Radioisotope Services Group of ICI operates a Triga Reactor in support of a commercial, Industrial Radioisotope Technology Service. The technical and commercial development of this business is discussed in the context of operating a Triga Reactor in an Industrial Environment. (author)

  4. Argon-41 production and evolution at the Oregon State University TRIGA Reactor (OSTR)

    International Nuclear Information System (INIS)

    Anellis, L.G.; Johnson, A.G.; Higginbotham, J.F.

    1988-01-01

    In this study, argon-41 concentrations were measured at various locations within the reactor facility to assess the accuracy of models used to predict argon-41 evolution from the reactor tank, and to determine the relationship between argon gas evolution from the tank and subsequent argon-41 concentrations throughout the reactor room. In particular, argon-41 was measured directly above the reactor tank with the reactor tank lids closed, at other accessible locations on the reactor top with the tank lids both closed and open, and at several locations on the first floor of the reactor room. These measured concentrations were then compared to values calculated using a modified argon-41 production and evolution model for TRIGA reactor tanks and ventilation values applicable to the OSTR facility. The modified model was based in part on earlier TRIGA models for argon-41 production and release, but added features which improved the agreement between predicted and measured values. The approximate dose equivalent rate due to the presence of argon-41 in reactor room air was calculated for several different locations inside the OSTR facility. These dose rates were determined using the argon-41 concentration measured at each specific location, and were subsequently converted to a predicted quarterly dose equivalent for each location based on the reactor's operating history. The predicted quarterly dose equivalent values were then compared to quarterly doses measured by film badges deployed as dose-integrating area radiation monitors at the locations of interest. The results indicate that the modified production and evolution model is able to predict argon-41 concentrations to within a factor of ten when compared to the measured data. Quarterly dose equivalents calculated from the measured argon-41 concentrations and the reactor's operating history seemed consistent with results obtained from the integrating area radiation monitors. Given the argon-41 concentrations measured

  5. Possibilities of miniaturizing the TRIGA-reactor

    International Nuclear Information System (INIS)

    Bobleter, O.; Brunner, P.; Schachner, H.

    1976-01-01

    It is proposed to decrease the depth of the TRIGA pool in cases where the construction of the normal-sized pool causes difficulty. The loss of shielding in the vertical direction will be compensated by lead and lead glass. The influence of these changes in design on the reactor components (control rods, instrumentation, neutron beam tubes, pneumatic system, etc.) is discussed. The experimental part of the work concerns the irradiation of lead glasses with varying contents of lead and cerium, which was carried out in the pool at different distances from the TRIGA core. The advantages of a possible reduction in size of the TRIGA reactor by using lead and lead glass as shielding are compared with the main disadvantages of these materials (darkening of the glass and high prices). (author)

  6. 7. European conference of TRIGA reactor users. Conference papers

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1982-07-01

    At the Seventh European Conference of TRIGA Users, held in September 1982, in Istanbul, Turkey, the following aspects are discussed: safety aspects of TRIGA reactors; developments and improvements; operating and maintenance experiences; applications; reactor calculations; fuel cycle aspects and research programs.

  7. 7. European conference of TRIGA reactor users. Conference papers

    International Nuclear Information System (INIS)

    1982-01-01

    At the Seventh European Conference of TRIGA Users, held in September 1982, in Istanbul, Turkey, the following aspects are discussed: safety aspects of TRIGA reactors; developments and improvements; operating and maintenance experiences; applications; reactor calculations; fuel cycle aspects and research programs

  8. Monte Carlo modelling of TRIGA research reactor

    Science.gov (United States)

    El Bakkari, B.; Nacir, B.; El Bardouni, T.; El Younoussi, C.; Merroun, O.; Htet, A.; Boulaich, Y.; Zoubair, M.; Boukhal, H.; Chakir, M.

    2010-10-01

    The Moroccan 2 MW TRIGA MARK II research reactor at Centre des Etudes Nucléaires de la Maâmora (CENM) achieved initial criticality on May 2, 2007. The reactor is designed to effectively implement the various fields of basic nuclear research, manpower training, and production of radioisotopes for their use in agriculture, industry, and medicine. This study deals with the neutronic analysis of the 2-MW TRIGA MARK II research reactor at CENM and validation of the results by comparisons with the experimental, operational, and available final safety analysis report (FSAR) values. The study was prepared in collaboration between the Laboratory of Radiation and Nuclear Systems (ERSN-LMR) from Faculty of Sciences of Tetuan (Morocco) and CENM. The 3-D continuous energy Monte Carlo code MCNP (version 5) was used to develop a versatile and accurate full model of the TRIGA core. The model represents in detailed all components of the core with literally no physical approximation. Continuous energy cross-section data from the more recent nuclear data evaluations (ENDF/B-VI.8, ENDF/B-VII.0, JEFF-3.1, and JENDL-3.3) as well as S( α, β) thermal neutron scattering functions distributed with the MCNP code were used. The cross-section libraries were generated by using the NJOY99 system updated to its more recent patch file "up259". The consistency and accuracy of both the Monte Carlo simulation and neutron transport physics were established by benchmarking the TRIGA experiments. Core excess reactivity, total and integral control rods worth as well as power peaking factors were used in the validation process. Results of calculations are analysed and discussed.

  9. Safety-evaluation report related to the renewal of the operating license for the Cornell University TRIGA Research Reactor. Docket No. 50-157

    International Nuclear Information System (INIS)

    1983-08-01

    This Safety Evaluation Report for the application filed by the Cornell University for a renewal of Operating License R-80 to continue to operate a research reactor has been prepared by the Office of Nuclear Reactor Regulation of the US Nuclear Regulatory Commission. The facility is owned and operated by Cornell University and is located on the Cornell campus in Ithaca, New York. The staff concludes that the TRIGA reactor facility can continue to be operated by Cornell without endangering the health and safety of the public

  10. TRIGA reactor as an experimental tool

    Energy Technology Data Exchange (ETDEWEB)

    Nahrul Khair bin Alang Mohammad Rashid (PUSPATI, Selangor (Malaysia))

    1981-01-01

    Article reviewed on the general features, operation and capabilities, and utilization of a research reactor, PUSPATI TRIGA MARK II. The paper also described the arrangements for the use of the PUSPATI reactor.

  11. Triga reactor as an experimental tool

    International Nuclear Information System (INIS)

    Nahrul Khair bin Alang Mohammad Rashid

    1981-01-01

    Article reviewed on the general features, operation and capabilities, and utilization of a research reactor, PUSPATI TRIGA MARK II. The paper also described the arrangements for the use of the PUSPATI reactor

  12. INR TRIGA Research Reactors: A Neutron Source for Radioisotopes and Materials Investigation

    International Nuclear Information System (INIS)

    Barbos, D.; Ciocanescu, M.; Paunoiu, C.; Bucsa, A.F.

    2013-01-01

    At the INR there are 2 high intensity neutron sources. These sources are in fact the two nuclear TRIGA reactors: TRIGA SSR 14 MW and TRIGA ACPR. TRIGA stationary reactor is provided with several in-core irradiation channels. Other several out-of-core irradiation channels are located in the vertical channels in the beryllium reflector blocks. The maximum value of the thermal neutron flux (E 14 cm -2 s -1 and of fast neutron flux (E>1 MeV) is 6.89×10 13 cm -2 s -1 . For neutron activation analysis both reactors are used and k0-NAA method has been implemented. At INR Pitesti a prompt gamma ray neutron activation analysis devices has been designed, manufactured ant put into operation. For nuclear materials properties investigation neutron radiography methods was developed in INR. For these purposes two neutron radiography devices were manufacture, one of them underwater and other one dry. The neutron beams are used for investigation of materials properties and components produced or under development for applications in the energy sector (fission and fusion). At TRIGA 14 MW reactor a neutron difractormeter and a SANS devices are available for material residual stress and texture measurements. TRIGA 14 MW reactor is used for medical and industrial radioisotopes production ( 131 I, 125 I, 192 Ir, etc) and a method for 99 Mo- 99 Tc production from fission is under developing. At INR Pitesti several special programmes for new types of nuclear fuel behavior characterization are under development. (author)

  13. The influence of Triga 2000 reactor operation on the surface contamination at reactor room using smear test method

    International Nuclear Information System (INIS)

    Bintu Khoiriyyah; Budi Purnama; Tri Cahyo Laksono

    2016-01-01

    The monitoring of surface contamination should be conducted to determine the safety of work areas. Surface contamination at the TRIGA 2000 reactor room which is on PSTNT-BATAN Bandung remain to be implemented although reactor not operating. In this research monitoring of surface contamination when TRIGA 2000 in operation of the first time after several years not operating aims to determine the influence on the results of monitoring. The monitoring of surface contamination has been done using smear test method at some predetermined in TRIGA 2000 reactor room. The highest surface contamination activities is obtained 0.32 Bq/cm 2 and there are some points that are not detected. Based on keputusan kepala BAPETEN No.1/Ka BAPETEN/ V/99 the work showed that the TRIGA 2000 reactor in the category of low area contamination, that is <3.7 Bq/cm 2 to gross beta. (author)

  14. Safety evaluation report related to the renewal of the operating license for the Washington State University TRIGA reactor. Docket No. 50-27

    International Nuclear Information System (INIS)

    1982-05-01

    This Safety Evaluation Report for the application filed by the Washington State University (WSU) for a renewal of operating license number R-76 to continue to operate a research reactor has been prepared by the Office of Nuclear Reactor Regulation of the US Nuclear Regulatory Commission. The facility is owned and operated by the Washington State University and is located on the WSU campus in Pullman, Whitman County, Washington. The staff concludes that the TRIGA reactor facility can continue to be operated by WSU without endangering the health and safety of the public

  15. Neutron optics experiments at the TRIGA Mark II reactor of the Atominstitut Wien

    International Nuclear Information System (INIS)

    Jericha, E.; Badurek, G.; Baron, M.; Hasegawa, Y.; Jaekel, M.; Klepp, J.; Rofner, A.; Sponar, S.; Trinker, M.; Villa, M.; Rauch, H.

    2004-01-01

    We present the layout and characteristics of the 3 neutron optics instruments located at the beam ports of the Vienna TRIGA reactor (hosted by the Atominstitut of the Austrian Universities, Vienna University of Technology) and the most recent experiments performed thereon. (author)

  16. Fission product release from TRIGA-LEU reactor fuels

    International Nuclear Information System (INIS)

    Baldwin, N.L.; Foushee, F.C.; Greenwood, J.S.

    1980-01-01

    Due to present international concerns over nuclear proliferation, TRIGA reactor fuels will utilize only low-enriched uranium (LEU) (enrichment <20%). This requires increased total uranium loading per unit volume of fuel in order to maintain the appropriate fissile loading. Tests were conducted to determine the fractional release of gaseous and metallic fission products from typical uranium-zirconium hydride TRIGA fuels containing up to 45 wt-% uranium. These tests, performed in late 1977 and early 1978, were similar to those conducted earlier on TRIGA fuels with 8.5 wt-% U. Fission gas release measurements were made on prototypic specimens from room temperature to 1100 deg. C in the TRIGA King Furnace Facility. The fuel specimens were irradiated in the TRIGA reactor at a low power level. The fractional releases of the gaseous nuclides of krypton and xenon were measured under steady-state operating conditions. Clean helium was used to sweep the fission gases released during irradiation from the furnace into a standard gas collection trap for gamma counting. The results of these tests on TRIGA-LEU fuel agree well with data from the similar, earlier tests on TRIGA fuel. The correlation used to calculate the release of fission products from 8.5 wt-% U TRIGA fuel applies equally well for U contents up to 45 wt-%. (author)

  17. Decommissioning of TRIGA Mark II type reactor

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Dooseong; Jeong, Gyeonghwan; Moon, Jeikwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-10-15

    The first research reactor in Korea, KRR 1, is a TRIGA Mark II type with open pool and fixed core. Its power was 100 kWth at its construction and it was upgraded to 250 kWth. Its construction was started in 1957. The first criticality was reached in 1962 and it had been operated for 36,000 hours. The second reactor, KRR 2, is a TRIGA Mark III type with open pool and movable core. These reactors were shut down in 1995, and the decision was made to decommission both reactors. The aim of the decommissioning activities is to decommission the KRR 2 reactor and decontaminate the residual building structures and site, and to release them as unrestricted areas. The KRR 1 reactor was decided to be preserve as a historical monument. A project was launched for the decommissioning of these reactors in 1997, and approved by the regulatory body in 2000. A total budget for the project was 20.0 million US dollars. It was anticipated that this project would be completed and the site turned over to KEPCO by 2010. However, it was discovered that the pool water of the KRR 1 reactor was leaked into the environment in 2009. As a result, preservation of the KRR 1 reactor as a monument had to be reviewed, and it was decided to fully decommission the KRR 1 reactor. Dismantling of the KRR 1 reactor takes place from 2011 to 2014 with a budget of 3.25 million US dollars. The scope of the work includes licensing of the decommissioning plan change, removal of pool internals including the reactor core, removal of the thermal and thermalizing columns, removal of beam port tubes and the aluminum liner in the reactor tank, removal of the radioactive concrete (the entire concrete structure will not be demolished), sorting the radioactive waste (concrete and soil) and conditioning the radioactive waste for final disposal, and final statuses of the survey and free release of the site and building, and turning over the site to KEPCO. In this paper, the current status of the TRIGA Mark-II type reactor

  18. Probabilistic Safety Assessment Of It TRIGA Mark-II Reactor

    International Nuclear Information System (INIS)

    Ergun, E; Kadiroglu, O.S.

    1999-01-01

    The probabilistic safety assessment for Istanbul Technical University (ITU) TRIGA Mark-II reactor is performed. Qualitative analysis, which includes fault and event trees and quantitative analysis which includes the collection of data for basic events, determination of minimal cut sets, calculation of quantitative values of top events, sensitivity analysis and importance measures, uncertainty analysis and radiation release from fuel elements are considered

  19. The TRIGA reactor as chemistry apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Miller, G E [University of California, Irvine (United States)

    1974-07-01

    At the Irvine campus of the University of California, the Mark I, 250 kilowatt TRIGA reactor is used as a regular teaching and research tool by the Department of Chemistry which operates the reactor. Students are introduced to radiochemistry and activation analysis in undergraduate laboratory courses and the relation of nuclear to chemical phenomena is emphasized even in Freshman chemistry. Special peripheral items have been developed for use in graduate and undergraduate research, including a fast pneumatic transfer system for studying short-lived isotopes and arrangements for irradiations at low temperatures. These and other unique features of a purely chemically oriented operation will be discussed and some remarks appended with regard to the merits of a low budget operation. (author)

  20. The TRIGA reactor as chemistry apparatus

    International Nuclear Information System (INIS)

    Miller, G.E.

    1974-01-01

    At the Irvine campus of the University of California, the Mark I, 250 kilowatt TRIGA reactor is used as a regular teaching and research tool by the Department of Chemistry which operates the reactor. Students are introduced to radiochemistry and activation analysis in undergraduate laboratory courses and the relation of nuclear to chemical phenomena is emphasized even in Freshman chemistry. Special peripheral items have been developed for use in graduate and undergraduate research, including a fast pneumatic transfer system for studying short-lived isotopes and arrangements for irradiations at low temperatures. These and other unique features of a purely chemically oriented operation will be discussed and some remarks appended with regard to the merits of a low budget operation. (author)

  1. Experience in operation and maintenance of the TRIGA Mark II reactor at the University of Pavia in the time period July 1974 - June 1976

    International Nuclear Information System (INIS)

    Cambieri, A.; Cingoli, F.; Genova, N.; Meloni, S.; Perlini, G.

    1976-01-01

    The operation of the 250 kW steady state/250 MW pulsed TRIGA Mark II Reactor of the University of Pavia over the past two years is presented and discussed. Reactor maintenance activity is presented as well. Data for reactor utilization and a summary of the health physics procedures are also given. Since the third European Conference of TRIGA Reactor Users in 1974, reactor operation took place smoothly without major troubles. Because of the core excess decrease due to reactor operation and consequent burn-up, ten new stainless steel clad fuel elements were bought from General Atomic. Reactor operation license expired at the end of 1975 and it is now under way the bureaucratic work to get its renewal. The aging of the electronic equipment raises minor problems and the predicted switching to a new solid state equipment started by changing the old electromechanical rod position indicators with new digital ones. The installation of the Euracos II facility (Enriched Uranium Converter Source), described at the last TRIGA Users Conference, began at the end of 1975 and it is still under way. The first operation of the facility will take place at reduced power so that the removal of the graphite blocks from thermal column was not accomplished. The installation of the facility is described and the procedures of its operation in connection with reactor operation are presented as well. (author)

  2. An analysis of decommissioning costs for the AFRRI TRIGA reactor facility

    International Nuclear Information System (INIS)

    Forsbacka, Matt

    1990-01-01

    A decommissioning cost analysis for the AFRRI TRIGA Reactor Facility was made. AFRRI is not at this time suggesting that the AFRRI TRIGA Reactor Facility be decommissioned. This report was prepared to be in compliance with paragraph 50.33 of Title 10, Code of Federal Regulations which requires the assurance of availability of future decommissioning funding. The planned method of decommissioning is the immediate decontamination of the AFRRI TRIGA Reactor site to allow for restoration of the site to full public access - this is called DECON. The cost of DECON for the AFRRI TRIGA Reactor Facility in 1990 dollars is estimated to be $3,200,000. The anticipated ancillary costs of facility site demobilization and spent fuel shipment is an additional $600,000. Thus the total cost of terminating reactor operations at AFRRI will be about $3,800,000. The primary basis for this cost estimate is a study of the decommissioning costs of a similar reactor facility that was performed by Battelle Pacific Northwest Laboratory (PNL) as provided in USNRC publication NUREG/CR-1756. The data in this study were adapted to reflect the decommissioning requirements of the AFRRI TRIGA. (author)

  3. Irradiation positions for fission-track dating in the University of Pavia TRIGA Mark II nuclear reactor

    International Nuclear Information System (INIS)

    Oddone, Massimo; Meloni, Sandro; Balestrieri, Maria Laura; Bigazzi, Giulio

    2002-01-01

    An irradiation position arranged is described in the present paper for fission-track dating in the Triga Mark II reactor of the University of Pavia. Fluence values determined using the NIST glass standard SRM 962a for fission-track dating and the traditional metal foils are compared. Relatively good neutron thermalization (φ th /φ f = 0.956) and lack of significant fluence spatial gradients are good factors for fission-track dating. Finally, international age standards (or putative age standards) irradiated in this new position yielded results consistent with independent reference ages. (author)

  4. Operation experience with the TRIGA reactor Wien 2004

    International Nuclear Information System (INIS)

    Boeck, H.; Villa, M.

    2004-01-01

    The TRIGA Mark-II reactor in Vienna is now in operation for more than 42 years. The average operation time is about 230 days per year with 90 % of this time at nominal power of 250 kW. The remaining 10 % operation time is used for students' training courses at low power level. Pulse operation is rather infrequent with about 5 to 10 pulses per year. The utilization of this facility is excellent, the number of students participating in practical exercises has strongly increased, and also training courses for outside groups such as the IAEA or for the 2004 Eugene Wigner Course are using the reactor, because it is the only TRIGA reactor remaining in Austria. Therefore, there is no need for decommissioning and it is intended to operate it as long as possible into the next decade. Nevertheless, in early 2004 it was decided to prepare a report on a decommissioning procedure for a typical TRIGA Mark II reactor which lists the volumes, the activity and the weight of individual materials such as concrete, aluminium, stainless steel, graphite and others which will accumulate during this process (a summary of possible activated and contaminated materials and the activity of a single TRIGA fuel element as a function of fuel type and decay time in Bq is presented). The status of the reactor (instrumentation, fuel elements, cooling circuit, ventilation system, re-inspection and maintenance program, cost/benefit) is outlined. (nevyjel)

  5. Present and future use of TRIGA reactors in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Menke, H.; Junker, D.; Krauss, O.

    1986-01-01

    In the Federal Republic of Germany nine research reactors are presently in operation, three of which are TRIGA reactors. These are the TRIGA Mark I reactors at Hannover and Heidelberg with a steady state power of 250 kW and the TRIGA Mark II reactor at Mainz with a steady power of 100 kW and a peak pulsing power of 250 MW. The decommissioning of a number of research reactors, including the TRIGA Mark III reactor at Neuherberg near Munich, is reason enough to think about the present and future use of our reactors. The German TRIGA reactors met a lively interest of scientists, since they went into operation. Presently they are well used especially in biomedical (Hannover, Heidelberg) and basic research (Mainz). In the course of about 20 years of operation the techniques and requirements of experiments changed and consequently the use of the reactors too. Certainly this will be so in the future. But thanks to its versatile experimental facilities, this type of reactor can meet the various experimental demands. So we are looking forward to a good utilisation of our German TRIGA reactors in future and taking into account the low costs for personal, energy and fuel, we are quite confident that they will be in operation still for many years. (author)

  6. University Reactor Sharing Program. Final report, September 30, 1992--September 29, 1994

    International Nuclear Information System (INIS)

    Wehring, B.W.

    1995-01-01

    Over the past 20 years, the number of nuclear reactors on university campuses in the US declined from more than 70 to less than 40. Contrary to this trend, The University of Texas at Austin constructed a new reactor facility at a cost of $5.8 million. The new reactor facility houses a new TRIGA Mark II reactor which replaces an in-ground TRIGA Mark I reactor located in a 50-year old building. The new reactor facility was constructed to strengthen the instruction and research opportunities in nuclear science and engineering for both undergraduate and graduate students at The University of Texas. On January 17, 1992, The University of Texas at Austin received a license for operation of the new reactor. Initial criticality was achieved on March 12, 1992, and full power operation, on March 25, 1992. The UT-TRIGA research reactor provides hands-on education, multidisciplinary research and unique service activities for academic, medical, industrial, and government groups. Support by the University Reactor Sharing Programs increases the availability of The University of Texas reactor facility for use by other educational institutions which do not have nuclear reactors

  7. Some possibilities of utilisation of TRIGA reactors in the future

    International Nuclear Information System (INIS)

    Stegnar, Peter; Byrne, Anthony R.

    2008-01-01

    Full text. In this presentation, some possibilities for the future use of TRIGA reactors are discussed. The use and practical applications of neutron activation analysis, both in instrumental and radiochemical analysis, is presented based on the experience of the Institute's TRIGA Mark II Reactor in Ljubljana. The limited use of isotope production for medicine and industry is also discussed as well as some other potential applications, i.e. prompt gamma neutron activation analysis and an approach to BNCT (Boron Neutron Capture Therapy). The possibility of using TRIGA reactors for training in nuclear safety, radiological protection and other relevant fields of science and technology is also addressed in the presentation

  8. TRIGA International - History of Training Research Isotope production General Atomics

    International Nuclear Information System (INIS)

    2008-01-01

    TRIGA conceived at GA in 1956 by a distinguished group of scientists including Edward Teller and Freeman Dyson. First TRIGA reactor Mk-1 was commissioned on 3 may 1958 at G.A. Characteristic feature of TRIGA reactors is inherent safety: Sitting can be confinement or conventional building. TRIGA reactors are the most prevalent in the world: 67 reactors in 24 countries. Steady state powers up to 14 MWt, pulsing up to 22,000 MWt. To enlarge the scope of its manufactured products, CERCA engaged in a Joint Venture with General Atomics, and in July 1995 a new Company was founded: TRIGA INTERNATIONAL SAS (50% GA, 50% CERCA; Head Office: Paris (France); Sales offices: GA San Diego (Ca, USA) and CERCA Lyon (France); Manufacturing plant: CERCA Romans. General Atomics ID: founded in 1955 at San Diego, California, by General Dynamics; status: Privately held corporation; owners: Neal and Linden Blue; business: High technology research, design, manufacturing, and production for industry and Government in the U.S. and overseas; locations: U.S., Germany, Japan, Australia, Thailand, Morocco; employees: 5,000. TRIGA's ID: CERCA is a subsidiary of AREVA, born in November 05, 1957. Activities: fuel manufacture for research reactor, equipment and components for high-energy physics, radioactive sources and reference sources; plants locations: Romans and Pierrelatte (France); total strength: 180. Since the last five years TRIGA has manufactured and delivered more than 800 fuel elements with a door to door service. TRIGA International has the experience to manufacture all types of TRIGA fuel: standard fuel elements, instrumented fuel elements, fuel followed control rods, geometry: 37.3 mm (1.47 in.), 35.8 mm (1.4 in), 13 mm (0.5 in), chemical Composition: U w% 8.5, 12, 20, 30 and 45 w/o, erbium and no erbium. TRIGA International is on INL's approved vendor list (ISO 9000/NQA) and is ready to meet any TRIGA fuel needs either in the US or worldwide

  9. Research reactor back-end options - decommissioning: a necessary consideration

    International Nuclear Information System (INIS)

    England, M.R.; Parry, D.R.; Smith, C.

    1998-01-01

    Decommissioning is a challenge, which all radioactive site licensees eventually need to face and research reactors are no exception. BNFL has completed numerous major decommissioning projects at its own operational sites and has undertaken similar works at customers' sites including the decommissioning of the Universities Research Reactor (URR), Risley and the ICI TRIGA 1-Mk I Reactor at Billingham. Based on the execution of such projects BNFL has gained an understanding of the variety of customer requirements and the effectiveness of specific decommissioning techniques for research reactors. This paper addresses factors to be considered when reviewing the way forward following shut down and how these affect the final decisions for fuel management and the extent of decommissioning. Case studies are described from BNFL's recent experience decommissioning both the URR and ICI TRIGA reactors. (author)

  10. 10th European TRIGA users conference

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    Abstracts of 46 papers on various aspects of Triga reactors (mainly Triga Mark 2 reactors) are given, according to the main headings: reactor operation and maintenance experience; new developments and improvements of Triga components and systems, including instrumentation; fuel and fuel management; safety aspects, licensing and radiation protection; experiments with Triga reactors; radiochemistry, radioisotope production and NAA; reactor physics. (qui)

  11. The study of time-dependent neutronics parameters of the 2MW TRIGA Mark II Moroccan research reactor using BUCAL1 computer code

    International Nuclear Information System (INIS)

    Bakkari, B. El; Nacir, B.; El Younoussi, C.; Boulaich, Y.; Riyach, I.; Otmani, S.; Marcih, I.; Elbadri, H.; El Bardouni, T; Merroun, O.; Boukhal, H.; Zoubair, M.; Htet, A.; Chakir, M.

    2010-01-01

    The 2-MW TRIGA MARK II research reactor at Centre National de l'Energie, des Sciences et des Techniques Nucleaires (CNESTEN) achieved initial criticality on May 2, 2007 with 71 fuel elements. The reactor is designed to effectively implement the various fields of basic nuclear research, manpower and training and production of radioisotopes for their use in agriculture, industry and medicine. This work aims to study the time-dependent neutronics parameters of the TRIGA reactor for elaborating and planning of an in-core fuel management strategy to maximize the utilization of the TRIGA fluxes, using a new elaborated burnup computer code called 'BUCAL1'. The code can be used to aid in analysis, prediction, and optimization of fuel burnup performance in a nuclear reactor. It was developed to incorporate the neutron absorption tally/reaction information generated directly by MCNP5 code in the calculation of fissioned or neutron-transmuted isotopes for multi-fueled regions. The use of Monte Carlo method and punctual cross section data characterizing the MCNP code allows an accurate simulation of neutron life cycle in the reactor, and the integration of data on the entire energy spectrum, thus a more accurate estimation of results than deterministic code can do. Also, for the purpose of this study, a full-model of the TRIGA reactor was developed using the MCNP5 code. The validation of the MCNP model of the TRIGA reactor was made by benchmarking the reactivity experiments. (author)

  12. Generic Procedures for Response to a Nuclear or Radiological Emergency at Triga Research Reactors. Attachment 1 (2011)

    International Nuclear Information System (INIS)

    2011-01-01

    The publication provides guidance for response to emergencies at TRIGA research reactors in Threat Category II and III. It contains information on the unique behaviour of TRIGA fuel during accident conditions; it describes design characteristics of TRIGA research reactors and provides specific symptom-based emergency classification for this type of research reactor. This publication covers the determination of the appropriate emergency class and protective actions for a nuclear or radiological emergency at TRIGA research reactors. It does not cover nuclear security at TRIGA research reactors. The term 'threat category' is used in this publication as described in Ref. [6] and for the purposes of emergency preparedness and response only; this usage does not imply that any threat, in the sense of an intention and capability to cause harm, has been made in relation to facilities, activities or sources. The threat category is determined by an analysis of potential nuclear and radiological emergencies and the associated radiation hazard that could arise as a consequence of those emergencies. STRUCTURE. The attachment consists of an introduction which defines the background, objective, scope and structure, two sections covering technical aspects and appendices. Section 2 describes the characteristics of TRIGA fuel in normal and accident conditions. Section 3 contains TRIGA research reactor specific emergency classification tables for Threat Category II and III. These tables should be used instead of the corresponding emergency classification tables presented in Ref. [1] while developing the emergency response arrangements at TRIGA research reactors. The appendices present some historical overview and typical general data for TRIGA research reactor projects and the list of TRIGA installations around the world. The terms used in this document are defined in the IAEA Safety Glossary and the IAEA Code of Conduct on the Safety of Research Reactors.

  13. Isothermal temperature reactivity coefficient measurement in TRIGA reactor

    International Nuclear Information System (INIS)

    Zagar, T.; Ravnik, M.; Trkov, A.

    2002-01-01

    Direct measurement of an isothermal temperature reactivity coefficient at room temperatures in TRIGA Mark II research reactor at Jozef Stefan Institute in Ljubljana is presented. Temperature reactivity coefficient was measured in the temperature range between 15 o C and 25 o C. All reactivity measurements were performed at almost zero reactor power to reduce or completely eliminate nuclear heating. Slow and steady temperature decrease was controlled using the reactor tank cooling system. In this way the temperatures of fuel, of moderator and of coolant were kept in equilibrium throughout the measurements. It was found out that TRIGA reactor core loaded with standard fuel elements with stainless steel cladding has small positive isothermal temperature reactivity coefficient in this temperature range.(author)

  14. Qualitative assessment of the value of the Ohio State University TRIGA reactor

    International Nuclear Information System (INIS)

    Binney, S.E.; Johnson, A.G.

    1989-01-01

    The Oregon State University (OSU) TRIGA Reactor (OSTR) is a major regional research, training, and service facility. The OSTR supports a wide variety of organizations at the local, state, regional, national, and international levels. Examples of usage of the OSTR are given in this paper to serve as a basis for assessing the value of the OSTR to its user organizations. It is difficult to assess the value of a facility such as the OSTR quantitatively, primarily because a dollar value cannot be assigned to many of the services that the OSTR performs, e.g., forensic analysis to assist police agencies in criminal cases. Significant qualitative statements can be made, however, to demonstrate the fact that the value of a research reactor facility such as the OSTR substantially outweighs the capital and operating costs of such a facility. Analysis of the data presented above clearly indicates that the value of the OSTR facility is overwhelmingly positive, i.e., the benefits associated with the services provided by the OSTR facility outweigh the cost of providing such services by perhaps as much as an order of magnitude

  15. Optimum burnup of BAEC TRIGA research reactor

    International Nuclear Information System (INIS)

    Lyric, Zoairia Idris; Mahmood, Mohammad Sayem; Motalab, Mohammad Abdul; Khan, Jahirul Haque

    2013-01-01

    Highlights: ► Optimum loading scheme for BAEC TRIGA core is out-to-in loading with 10 fuels/cycle starting with 5 for the first reload. ► The discharge burnup ranges from 17% to 24% of U235 per fuel element for full power (3 MW) operation. ► Optimum extension of operating core life is 100 MWD per reload cycle. - Abstract: The TRIGA Mark II research reactor of BAEC (Bangladesh Atomic Energy Commission) has been operating since 1986 without any reshuffling or reloading yet. Optimum fuel burnup strategy has been investigated for the present BAEC TRIGA core, where three out-to-in loading schemes have been inspected in terms of core life extension, burnup economy and safety. In considering different schemes of fuel loading, optimization has been searched by only varying the number of fuels discharged and loaded. A cost function has been defined and evaluated based on the calculated core life and fuel load and discharge. The optimum loading scheme has been identified for the TRIGA core, the outside-to-inside fuel loading with ten fuels for each cycle starting with five fuels for the first reload. The discharge burnup has been found ranging from 17% to 24% of U235 per fuel element and optimum extension of core operating life is 100 MWD for each loading cycle. This study will contribute to the in-core fuel management of TRIGA reactor

  16. Recently-developed neutron activation analysis techniques utilizing the University of California at Irvine TRIGA Mark I reactor

    International Nuclear Information System (INIS)

    Guinn, V.P.; Chambless, D.; Cortes T, E.; DeLancey, K.; Garzonov, E.; Miller, D.A.; Miller, G.E.; Purcell, M.A.

    1976-01-01

    The University of California at Irvine (UCI) 250 kW TRIGA Mark I reactor is used extensively for neutron activation analysis (NAA) studies. These particularly include basic technique studies and application studies in the fields of environmental pollution, crime investigation, archaeology, oceanography, and geochemistry. In recent NAA studies at UCI, a number of techniques have been developed which considerably improve the usefulness of such a research reactor for NAA work, and which should be of interest and use to others. Six of these techniques will be described in further detail in the full paper. They are as follows: development and use of (1) an automated high-precision rapid transfer system for instrumental NAA measurements with induced activities having half lives as short as 0.5 second, (2) an automated measurement system and computer program for making accurate dead-time corrections under conditions where the Ge(Li) spectrometer deadtime is changing rapidly during the counting period, (3) a technique to minimize the loss of mercury from samples during reactor irradiation via the use of dry-ice-packed, vented TRIGA rotary rack tubes, (4) a technique for compacting powdered samples, by pre-irradiation treatment with a solution of paraffin in carbon disulfide, to provide reproducible irradiation and counting geometries, (5) a method utilizing hydrated antimony pentoxide (HAP) as a pre-irradiation treatment material for removal of sodium from aqueous and wet-ashed samples, and (6) a computerized system for predicting in advance of activation, from approximate known elemental compositions, the total counting rate, deadtime, spectrum shape, principal photopeaks, and approximate actual lower limits of instrumental NAA detection of designated elements for any selected irradiation and decay times. (author)

  17. Results from Accelerator Driven TRIGA Reactor Experiments at The University of Texas at Austin

    International Nuclear Information System (INIS)

    O'Kelly, S.; Braisted, J.; Krause, M.; Welch, L.

    2008-01-01

    Accelerator Driven Transmutation of High-Level Waste (ATW) is one possible solution to the fuel reprocessing back-end problem for the disposal of high level waste such as minor actinides (Am, Np or Cm) and long-lived fission products. International programs continue to support research towards the eventual construction and operation of a proton accelerator driven spallation neutron source coupled to a subcritical 'neutron amplifier' for more efficient HLW transmutation. This project was performed under DOE AFCI Reactor-Accelerator Coupling Experiments (RACE). A 20 MeV Electron Linac was installed in the BP no 5 cave placing neutron source adjacent to an offset reactor core to maximize neutron coupling with available systems. Asymmetric neutron injection 'wasted' neutrons due to high leakage but sufficient neutrons were available to raise reactor power to ∼100 watts. The Linac provided approximately 100 mA but only 50% reached target. The Linac cooling system could not prevent overheating at frequencies over 200 Hz. The Linac electron beam had harmonics of primary frequency and periodic low frequency pulse intensity changes. Neutron detection using fission chambers in current mode eliminated saturation dead time and produced better sensitivity. The Operation of 'dual shielded' fission chambers reduced electron noise from linac. Benchmark criticality calculation using start-up data showed that the MCNPX model overestimates reactivity. TRIGA core was loaded to just slightly supercritical by adding graphite elements and measuring reactivity of $0.037. MCNPX modeled TRIGA core with and without graphite to arrive at 'true' measured subcritical multiplication of 0.998733± 0.00069. Thus, Alpha for the UT-RACE TRIGA core was approximately 155.99 s -1 . The Stochastic Feynman-Alpha Method (SFM) accuracy was evaluated during transients and reactivity changes. SFM was shown to be a potential real-time method of reactivity determination in future ADSS but requires stable

  18. Dry reloading and packaging of spent fuel at TRIGA MARK I reactor of Medical University Hanover (MHH), Germany

    International Nuclear Information System (INIS)

    Haferkamp, D.

    2008-01-01

    Between 1994 and 1998 the equipment for dry reloading of a research reactor was developed by Noell, which was funded by the German Federal Government and State of Saxonia. The task of this development programme was the design and delivery of an equipment able to load the spent fuel into the shipping casks in a dry mode for research reactors, where wet loading inside the storage pool is impossible. ALARA and infrastructure conditions had to be taken into consideration. Most of the research reactors of TRIGA MARK I type or WWR-SM have operating modes for handling of spent fuel inside the pond or for transfer of spent fuel from pond to dry/wet storage pools. On the other hand, most of them cannot handle heavy weighted shipping casks inside the reactor building because of the crane capacity, or inside water pool because of dimensions and weight of shipping casks. A typical licensed normal operating procedure for spent fuel in research reactors (TRIGA MARK I) is shown. Dry unloading procedure is described. Additionally to the normal operating procedures at the MHH research reactor the following steps were necessary: - dry packaging of spent fuel elements into the loading units (six packs) in order to minimise the transfer and loading steps between the pool and shipping cask; - transfer of spent fuel loading units from dry storage pool to the shipping cask (outside the reactor building) in a shielded transfer cask; - dry reloading of loading units, into the shipping casks outside the reactor building. The Dry Reloading Equipment implies the following 5 items: 1. loading units (six packs), which includes: - capacity up to six spent fuel elements; - criticality safe placement of spent fuel elements; - handling of several spent fuel elements in an aluminium loading unit. 2. Special Transfer Cask, which includes: - shielded housing with locks; - gripper inside housing; - hoist outside housing; - computer aided operation mode for loading and unloading. 3. Transfer Vehicle

  19. The research reactor TRIGA Heidelberg II

    International Nuclear Information System (INIS)

    Maier-Borst, W.; Krauss, O.

    1988-01-01

    The reactor is in operation since the beginning of 1978. On the base of the working experience gathered during that time employing the TRIGA in biomedical research, especially the irradiation units have been extended or newly developed. Several TRIGA users have reported difficulties in using the rotary irradiation system. It became obvious that the alternatives to the original Lazy Susan are not commonly known. In this report, the open rotary system fed by a hydraulic rabbit system, which has proved successful in this form during the past ten years is presented

  20. Programs with societal benefits at the Cornell University TRIGA reactor

    International Nuclear Information System (INIS)

    Clark, D.D.; Aderhold, H.C.; Hossain, T.Z.

    1993-01-01

    In its 30 yr of operation, the Cornell TRIGA reactor has been used for many educational and research programs that provide general benefits to society. In addition to supporting graduate-level education of nuclear scientists and engineers, it has been extensively used in undergraduate and graduate courses and research by nonspecialists and, through the medium of tours, in education of the general public. Some educational functions have been described previously. In this paper, examples are presented of research of societal interest in nonnuclear fields. The first two rely mainly on radiography, and the remaining five on neutron activation analysis (NAA)

  1. Development of Reactor Console Simulator for PUSPATI TRIGA Reactor

    International Nuclear Information System (INIS)

    Mohd Idris Taib; Izhar Abu Hussin; Mohd Khairulezwan Abdul Manan; Nufarhana Ayuni Joha; Mohd Sabri Minhat

    2012-01-01

    The Reactor Console Simulator will be an interactive tool for operator training and teaching of PUSPATI TRIGA Reactor. Behaviour and characteristic for reactor console and reactor itself can be evaluated and understand. This Simulator will be used as complement for actual present reactor console. Implementation of man-machine interface is using computer screens, keyboard and mouse. Multiple screens are used to match the physical of present reactor console. LabVIEW software are using for user interface and mathematical calculation. Polynomial equation based on control rods calibration data as well as operation parameters record was used to calculate the estimated reactor console parameters. (author)

  2. 6. European conference of TRIGA reactor users. Conference papers

    International Nuclear Information System (INIS)

    1980-01-01

    The Sixth European Conference of TRIGA Users was held in September 1980, in Mainz, Germany under the joint sponsorship of INTERATOM and the Institut fur Kernchemie. The main areas of discussions were: Fuel cycle aspects; New reactor developments and improvements; TRIGA applications; Operating and maintenance experiences and Instrumentation

  3. Reactor TRIGA PUSPATI (RTP) spent fuel pool conceptual design

    International Nuclear Information System (INIS)

    Mohd Fazli Zakaria; Tonny Lanyau; Ahmad Nabil Ab Rahim

    2010-01-01

    Reactor TRIGA PUSPATI (RTP) is the one and only research reactor in Malaysia that has been safely operated and maintained since 1982. In order to enhance technical capabilities and competencies especially in nuclear reactor engineering a feasibility study on RTP power upgrading was proposed to serve future needs for advance nuclear science and technology in the country with the capability of designing and develop reactor system. The need of a Spent Fuel Pool begins with the discharge of spent fuel elements from RTP for temporary storage that includes all activities related to the storage of fuel until it is either sent for reprocessed or sent for final disposal. To support RTP power upgrading there will be major RTP systems replacement such as reactor components and a new temporary storage pool for fuel elements. The spent fuel pool is needed for temporarily store the irradiated fuel elements to accommodate a new reactor core structure. Spent fuel management has always been one of the most important stages in the nuclear fuel cycle and considered among the most common problems to all countries with nuclear reactors. The output of this paper will provide sufficient information to show the Spent Fuel Pool can be design and build with the adequate and reasonable safety assurance to support newly upgraded TRIGA PUSPATI TRIGA Research Reactor. (author)

  4. Operation and maintenance of 1MW PUSPATI TRIGA reactor

    International Nuclear Information System (INIS)

    Adnan Bokhari; Mohammad Suhaimi Kassim

    2006-01-01

    The Malaysian Research Reactor, Reactor TRIGA PUSPATI (RTP) has been successfully operated for 22 years for various experiments. Since its commissioning in June 1982 until December 2004, the 1MW pool-type reactor has accumulated more than 21143 hours of operation, corresponding to cumulative thermal energy release of about 14083 MW-hours. The reactor is currently in operation and normally operates on demand, which is normally up to 6 hours a day. Presently the reactor core is made up of standard TRIAGA fuel element consists of 8.5 wt%, 12 wt% and 20 wt% types; 20%-enriched and stainless steel clad. Several measures such as routine preventive maintenance and improving the reactor support systems have been taken toward achieving this long successful operation. Besides normal routine utilization like other TRIGA reactors, new strategies are implemented for effective increase in utilization. (author)

  5. The Core Conversion of the TRIGA Reactor Vienna

    International Nuclear Information System (INIS)

    Villa, M.; Bergmann, R.; Musilek, A.; Sterba, J.H.; Böck, H.; Messick, C.

    2016-01-01

    The TRIGA Reactor Vienna has operated for many years with a mixed core using Al-clad and stainless-steel (SST) clad low enriched uranium (LEU) fuel and a few SST high enriched uranium (HEU) fuel elements. In view of the US spent fuel return program, the average age of these fuel elements and the Austrian position not to store any spent nuclear fuel on its territory, negotiation started in April 2011 with the US Department of Energy (DOE) and the International Atomic Energy Agency (IAEA). The sensitive subject was to return the old TRIGA fuel and to find a solution for a possible continuation of reactor operation for the next decades. As the TRIGA Vienna is the closest nuclear facility to the IAEA headquarters, high interest existed at the IAEA to have an operating research reactor nearby, as historically close cooperation exists between the IAEA and the Atominstitut. Negotiation started before summer 2011 between the involved Austrian ministries, the IAEA and the US DOE leading to the following solution: Austria will return 91 spent fuel elements to the Idaho National Laboratory (INL) while INL offers 77 very low burnt SST clad LEU elements for further reactor operation of the TRIGA reactor Vienna. The titles of these 77 new fuel elements will be transferred to Euratom in accordance with Article 86 of the Euratom-US Treaty. The fuel exchange with the old core returned to the INL, and the new core transferred to Vienna was carried out in one shipment in late 2012 through the ports of Koper/Slovenia and Trieste/Italy. This paper describes the administrative, logistic and technical preparations of the fuel exchange being unique world-wide and first of its kind between Austria and the USA performed successfully in early November 2012. (author)

  6. Research work with TRIGA Mark II at the Nuclear Chemistry Section of the 'J. Stefan' Institute in Ljubljana

    International Nuclear Information System (INIS)

    Byrne, A.R.; Dermelj, M.; Kosta, L.; Ravkin, V.; Stegnar, P.

    1978-01-01

    The general features of our research programme using TRIGA MK II, as outlined at the last TRIGA Reactor Users Conference in Vienna, September 28-30,1976, remain the same; namely, neutron activation analysis for trace and some minor elements. The four main areas presently investigated are a) environmental studies, b) life sciences research, c) standardization and d) methodology for specific problems arising in the first three topics

  7. Research projects at the TRIGA-reactor Vienna

    International Nuclear Information System (INIS)

    Boeck, H.; Buchberger, T.; Buchtela, K.; Hammer, J.; Miksovsky, A.; Veider, A.; Weber, H.W.; Zugarek, G.

    1986-01-01

    In 1985 the thermalizing column was modified to a beam tube with a conical collimator for neutron radiography. A highly sophisticated sample and cassette changer will be constructed in the next months. The central channel of the thermal column is also used for neutron radiography especially for small objects. The four beam tubes of the TRIGA-reactor are intensively used for neutron spectroscopy, small angle scattering, neutron interferometry and investigations of magnetic structures with polarized neutrons. The neutron activation installation in the piecing beam tube is permanently used for various sample analysis using a ultrafast pneumatic transfer system. In addition to these experiments directly related to the TRIGA-reactor other research projects are carried out, some of them under an IAEA research contract which are mostly focused towards nuclear safeguards such as the magnetic scanning of power reactor fuel assemblies or the laser surveillance system of spent fuel pools. (author)

  8. Thermal hydraulic analysis of the IPR-R1 TRIGA reactor

    International Nuclear Information System (INIS)

    Veloso, Marcelo Antonio; Fortini, Maria Auxiliadora

    2002-01-01

    The subchannel approach, normally employed for the analysis of power reactor cores that work under forced convection, have been used for the thermal hydraulic evaluation of a TRIGA Mark I reactor, named IPR-R1, at 250 kW power level. This was accomplished by using the PANTERA-1P subchannel code, which has been conveniently adapted to the characteristics of natural convection of TRIGA reactors. The analysis of results indicates that the steady state operation of IPR-R1 at 250 kW do not imply risks to installations, workers and public. (author)

  9. Characteristics and uses of a 250 kW TRIGA reactor

    International Nuclear Information System (INIS)

    Dimic, V.

    1985-01-01

    The 250 kW TRIGA Mark II reactor is a light water reactor with solid fuel elements in which the zirconium hydride moderator is homogeneously distributed between enriched uranium. Therefore the reactor has the large prompt negative temperature coefficient of reactivity, the fuel also has very high retention of radioactive fission products. The reactor core is a cylindrical configuration with an annular graphite reflector. The experimental facilities include a rotary specimen rack, a central incore radiation thimble, a pneumatic transfer system, and pulsing capability. Other experimental facilities include two radial and two tangential beam tubes, a graphite thermal column, and a graphite thermalizing column. At the steady state power of 250 kW the peak flux is 1x10 13 n/cm 2 s in the central test position. In addition, pulsing to about 2000 MW is usually provided giving peak fluxes of about 2x10 16 n/cm 2 sec. All TRIGA reactors produce a core-average thermal neutron flux of about 10 7 n.v per watt. Only with very large accelerators could such a high neutron flux be achieved. In order to give an appreciation for the research conducted at research reactors, the types of research could be summarized as follows: thermal neutron scattering, neutron radiography, neutron and nuclear physics, activation analysis, radiochemistry, biology and medicine, and teaching and training. Typical applied research with a 250 kW reactor has been conducted in medicine in biology, archeology, metallurgy and materials science, engineering and criminology. It is well known that research reactors have been used routinely to produce isotopes for industry and medicine. In some instances, reactors are the preferred method of isotope production. We can conclude that the 250 kW TRIGA research reactor is a useful and wide ranging source of radiation for basic and applied research. The operation cost for this instrument is relatively low. (author)

  10. Decontamination and decommissioning project status of the TRIGA mark-2±3 research reactors

    International Nuclear Information System (INIS)

    Jung, K. J.; Baek, S. T.; Jung, W. S.; Park, S. K.; Jung, K. H.

    1999-01-01

    TRIGA Mark-II, the first research reactor in Korea, has operated since 1962, and the second one, TRIGA Mark-III since 1972. Both of them had their operation phased out in 1995 due to their lives and operation of the new research reactor, HANARO at the Korea Atomic Energy Research Institute (KAERI) in Taejeon. Decontamination and decommissioning (D and D) project of the TRIGA Mark-II and Mark-III was started in January 1997 and will be completed in December 2002. In the first year of the project, work was performed in preparation of the decommissioning plan, start of the environmental impact assessment and setup licensing procedure and documentation for the project with cooperation of Korea Institute of Nuclear Safety (KINS). In 1998, Hyundai Engineering Company (HEC) is the main contractor to do design and licensing documentation for the D and D of both reactors. British Nuclear Fuels plc (BNFL) is technical assisting partner of HEC. The decommissioning plan document was submitted to the Ministry of Science and Technology (MOST) for the decommissioning license in December 1998, and it expecting to be issued a license at the end of September 1999. The goal of this project is to release the reactor site and buildings as an unrestricted area. This paper summarizes current status and future plan for the D and D project

  11. Establishment of the observing system for boron in steels by alpha-particle track etching method using JAERI reactor

    International Nuclear Information System (INIS)

    Asakura, Kentaro; Shibata, Koji; Sawahata, Hiroyuki; Kawate, Minoru; Harasawa, Susumu

    2003-01-01

    Alpha-particle track etching (ATE) method is most effective in observing boron distribution in steels. Previously, in Japan, neutron irradiation for this method was carried out in the reactor at the Institute of Atomic Energy, Rikkyo University. This reactor, however, was shut down in 1999. Therefore, the establishment of a new system for ATE method has been required and experimental research was performed using the reactor at the Japan Atomic Energy Research Institute (JAERI). It was clarified that the irradiation equipment for medical treatment of the reactor JRR-4 was most suitable for ATE method. The specimen trestle for low radioactive exposure was newly-developed. ATE image obtained by 12h irradiation using this trestle showed a good quality similar to that obtained using Rikkyo's reactor and that obtained using the trestle of the old model. Using this new trestle, the amount of neutron which the worker suffers during the operation at the irradiation equipment decreases from 4μSv/h to 0-1 μSv/h compared with the trestle of the old model. The total amount of thermal neutron after 12 h irradiation was almost same as that under the recommended condition of the reactor at Rikkyo University, 6.5 x 10 14 n cm -2 . (author)

  12. The optimal control of ITU TRIGA Mark II Reactor

    International Nuclear Information System (INIS)

    Can, Burhanettin

    2008-01-01

    In this study, optimal control of ITU TRIGA Mark-II Reactor is discussed. A new controller has been designed for ITU TRIGA Mark-II Reactor. The controller consists of main and auxiliary controllers. The form is based on Pontragyn's Maximum Principle and the latter is based on PID approach. For the desired power program, a cubic function is chosen. Integral Performance Index includes the mean square of error function and the effect of selected period on the power variation. YAVCAN2 Neutronic - Thermal -Hydraulic code is used to solve the equations, namely 11 equations, dealing with neutronic - thermal - hydraulic behavior of the reactor. For the controller design, a new code, KONTCAN, is written. In the application of the code, it is seen that the controller controls the reactor power to follow the desired power program. The overshoot value alters between 100 W and 500 W depending on the selected period. There is no undershoot. The controller rapidly increases reactivity, then decreases, after that increases it until the effect of temperature feedback is compensated. Error function varies between 0-1 kW. (author)

  13. CD3 TRIGA users conference

    International Nuclear Information System (INIS)

    2008-01-01

    The Sixteenth European TRIGA Users Conference was held in Pitesti, Romania, on 25-28 September, 2000, under the sponsorship of the Institute for Nuclear Research at Pitesti. The papers which follow in this document are presented in the same order as listed in the Conference Program. All papers which were received for publication (44) have been included. Those papers which were presented but not received for publication are presented in abstract form (4 papers). It was very interesting for the Conference attendees from the West to learn about the large scope of excellent work conducted in Romania, especially at the Institute of Nuclear Research in Pitesti. Similarly, it was fortunate that a large attendance of Romanian researchers (53) from many institutes, universities, and government agencies could attend the Conference and interact with their counterparts from outside Romania. The European TRIGA9 Owners' Group was fortunate to be hosted by the owners and users of the world's largest TRIGA reactor - the 14-MW Romanian research and test reactor. The Opening Session talk was given by Radu Berceanu, Minister of Industries and Commerce. It was followed by the following presentations: R and D - Support for Nuclear Power Development by Ioan Rotaru (General Manager of SNNE); Overview of TRIGA Reactor and other Programs at GENERAL ATOMICS by Junaid Razvi (General Manager TRIGA Reactor at GA); Development strategies connected to National Power and Energy Program by Mircea Ionescu (Director Nuclear Energy Department of M.I.C.); Contribution of INR R and D Programs to Sustain Peaceful and Safe utilization of Nuclear Energy in Romania by Constantin Gheorghiu (Scientific Deputy Director at SCN). A Technical visit to TRIGA Reactor at INR Pitesti took place. Opening Session was followed by five sessions dedicated to the following subjects: Session 1 (8 papers) - TRIGA reactors operation, repair and maintenance; Session 2 (10 papers) - Future developments and future goals of

  14. Applications of the Dow TRIGA research reactor

    International Nuclear Information System (INIS)

    Kocher, C.W.; Quinn, T.J.; Krueger, D.A.

    1982-01-01

    The Dow TRIGA Mark I reactor is a one-hundred kilowatt nuclear reactor installed by General Atomics using the Torrey Pines reactor console, seventy-five used stainless-steel clad fuel elements and one new aluminium clad fuel element. The reactor is equipped with a forty-position rotating Lazy Susan in the reflector, a pneumatic transfer system with its terminal in the F-ring of the core, and a central thimble which can be used for irradiation of samples in the center of the core or which can be emptied of the shielding water to produce a beam of neutrons and gamma rays in the area atop the pool. Samples can also be irradiated in or near the core. There is no provision for pulsing this TRIGA reactor. The neutron activation analysis program uses the Dow TRIGA reactor as a source of thermal neutrons and a Kaman A711 generator as a source of 14-MeV neutrons. The associated counting equipment includes one Gel(Li) detector and two Nal(Tl) detectors, each using a 100-position sample changer and all interfaced to a Tracor-Northern TN-11 data acquisition and computing system, one Ge(Li) detector and its TN-11 system for the pneumatic transfer system and the beam tube experiments, and two NaKTl)detectors with a TN-4000 system used with the Kaman neutron generator. The activation analysis program gets samples from all parts of the manufacturing and research efforts at Dow: raw materials, intermediates, products, effluents, research samples, samples from customers who use Dow products, and environmental samples. This presentation is devoted to the progress made in the past year on the pneumatic transfer system and the renewed work on prompt gamma-ray spectroscopy including the extensive process of method validation

  15. Component failure data base of TRIGA reactors

    International Nuclear Information System (INIS)

    Djuricic, M.

    2004-10-01

    This compilation provides failure data such as first criticality, component type description (reactor component, population, cumulative calendar time, cumulative operating time, demands, failure mode, failures, failure rate, failure probability) and specific information on each type of component of TRIGA Mark-II reactors in Austria, Bangladesh, Germany, Finland, Indonesia, Italy, Indonesia, Slovenia and Romania. (nevyjel)

  16. Pulsed TRIGA reactor as substitute for long pulse spallation neutron source

    International Nuclear Information System (INIS)

    Whittemore, W.L.

    1999-01-01

    those from the LPSS but at a considerably lower cost. Using the well proven and developed TRIGA reactor technology for this application would avoid the many complexities associated with either increasing the power of spallation sources or increasing the pulse length for the LPSS. An increasing problem with the spallation target is the thermal fatigue in the LPSS, a problem avoided in the pulsed TRIGA reactor. A properly designed cold source installed in a D 2 O reflector of the multiple pulsed TRIGA reactor can provide pulsed cold neutrons for neutron guides used in many neutron scattering applications. (author)

  17. Performance Monitoring for Nuclear Safety Related Instrumentation at PUSPATI TRIGA Reactor (RTP)

    International Nuclear Information System (INIS)

    Zareen Khan Abdul Jalil Khan; Ridzuan Abdul Mutalib; Mohd Sabri Minhat

    2015-01-01

    The Reactor TRIGA PUSPATI (RTP) at Malaysia Nuclear Agency is a TRIGA Mark II type reactor and pool type cooled by natural circulation of light water. This paper describe on performance monitoring for nuclear safety related instrumentation in TRIGA PUSPATI Reactor (RTP) of based on various parameter of reactor safety instrument channel such as log power, linear power, Fuel temperature, coolant temperature will take into consideration. Methodology of performance on estimation and monitoring is to evaluate and analysis of reactor parameters which is important of reactor safety and control. And also to estimate power measurement, differential of log and linear power and fuel temperature during reactor start-up, operation and shutdown .This study also focus on neutron power fluctuation from fission chamber during reactor start-up and operation. This work will present result of performance monitoring from RTP which indicated the safety parameter identification and initiate safety action on crossing the threshold set point trip. Conclude that performance of nuclear safety related instrumentation will improved the reactor control and safety parameter during reactor start-up, operation and shutdown. (author)

  18. Study on Reactor Performance of Online Power Monitoring in PUSPATI TRIGA Reactor (RTP)

    International Nuclear Information System (INIS)

    Zareen Khan Abdul Jalil Khan; Ridzuan Abdul Mutalib; Mohd Sabri Minhat

    2014-01-01

    The Reactor TRIGA PUSPATI (RTP) at Malaysia Nuclear Agency is a TRIGA Mark II type reactor and pool type cooled by natural circulation of light water. This paper describe on reactor performance of online power monitoring based on various parameter of reactor such as log power, linear power, period, Fuel and coolant temperature and reactivity parameter with using neutronic and other instrumentation system of reactor. Methodology of online power estimation and monitoring is to evaluate and analysis of reactor power which is important of reactor safety and control. Neutronic instrumentation system will use to estimate power measurement, differential of log and linear power and period during reactor operation .This study also focus on noise fluctuation from fission chamber during reactor operation .This work will present result of online power monitoring from RTP which indicated the safety parameter identification and initiate safety action on crossing the threshold set point trip. Conclude that optimization of online power monitoring will improved the reactor control and safety parameter of reactor during operation. (author)

  19. Home-made refurbishment of the instrumentation and control system of the TRIGA reactor of the University of Pavia

    International Nuclear Information System (INIS)

    Borio di Tigliole, A.; Cagnazzo, M.; Magrotti, G.; Manera, S.; Salvini, A.; Musitelli, G.; Nardo, R.

    2008-01-01

    The Instrumentation and Control (I and C) System of the TRIGA reactor of the University of Pavia was dated and, in order to grant a safe and continuous reactor operation for the future, it became necessary to substitute or to upgrade the system. Since the substitution of the I and C system with a new-made one was very difficult to be performed due to long authorization procedures, an home-made refurbishment was planned. Using commercial components of high quality, almost a complete substitution, channel-by-channel, of the I and C system was realized without changing the operating and safety logics. The system includes: - the Reactor Linear Power Channel and Chart Recorder; - the Reactor Percent Power Safety Channel; - the High Voltage and Low Voltage Power Supply; - the Automatic Reactor Power Control; - the Fuel Elements and Cooling-Water Temperatures Measuring Channels; - the Water Conductivity Measuring Channel. The refurbished I and C system shows a very good operational behavior and reliability and will assure a continuous operation of the reactor for the future

  20. Present Services at the TRIGA Mark II Reactor of the JSI

    International Nuclear Information System (INIS)

    Smodiš, B.; Snoj, L.

    2013-01-01

    The TRIGA Mark II research reactor of the Jožef Stefan Institute has been continuously operating since the year 1966. The currently offered services include: (1) Neutron activation analysis in both instrumental and radiochemical modes; (2) neutron irradiation of various kinds of materials intended to be used for research and applicative purposes; (3) training and education of university students as well as on-job training of staff working in public and private institutions, (4) verification of computer codes and nuclear data, comprising primarily criticality calculations and neutron flux distribution studies and (5) testing and development of a digital reactivity meter. The paper briefly describes the aforementioned activities and shows that even such small reactors are still indispensable in nuclear science and technology. (author)

  1. Thermal hydraulic analysis of the IPR-R1 TRIGA reactor; Analise termo-hidraulica do reator TRIGA IPR-R1

    Energy Technology Data Exchange (ETDEWEB)

    Veloso, Marcelo Antonio [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), Belo Horizonte, MG (Brazil); Fortini, Maria Auxiliadora [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear

    2002-07-01

    The subchannel approach, normally employed for the analysis of power reactor cores that work under forced convection, have been used for the thermal hydraulic evaluation of a TRIGA Mark I reactor, named IPR-R1, at 250 kW power level. This was accomplished by using the PANTERA-1P subchannel code, which has been conveniently adapted to the characteristics of natural convection of TRIGA reactors. The analysis of results indicates that the steady state operation of IPR-R1 at 250 kW do not imply risks to installations, workers and public. (author)

  2. Decommissioning of the Northrop TRIGA reactor

    International Nuclear Information System (INIS)

    Cozens, George B.; Woo, Harry; Benveniste, Jack; Candall, Walter E.; Adams-Chalmers, Jeanne

    1986-01-01

    An overview of the administrative and operational aspects of decommissioning and dismantling the Northrop Mark F TRIGA Reactor, including: planning and preparation, personnel requirements, government interfacing, costs, contractor negotiations, fuel shipments, demolition, disposal of low level waste, final survey and disposition of the concrete biological shielding. (author)

  3. Safety analysis and optimization of the core fuel reloading for the Moroccan TRIGA Mark-II reactor

    International Nuclear Information System (INIS)

    Nacir, B.; Boulaich, Y.; Chakir, E.; El Bardouni, T.; El Bakkari, B.; El Younoussi, C.

    2014-01-01

    Highlights: • Additional fresh fuel elements must be added to the reactor core. • TRIGA reactor could safely operate around 2 MW power with 12% fuel elements. • Thermal–hydraulic parameters were calculated and the safety margins are respected. • The 12% fuel elements will have no influence on the safety of the reactor. - Abstract: The Moroccan TRIGA MARK II reactor core is loaded with 8.5% in weight of uranium standard fuel elements. Additional fresh fuel elements must periodically be added to the core in order to remedy the observed low power and to return to the initial reactivity excess at the End Of Cycle. 12%-uranium fuel elements are available to relatively improve the short fuel lifetime associated with standard TRIGA elements. These elements have the same dimensions as standards elements, but with different uranium weight. The objective in this study is to demonstrate that the Moroccan TRIGA reactor could safely operate, around 2 MW power, with new configurations containing these 12% fuel elements. For this purpose, different safety related thermal–hydraulic parameters have been calculated in order to ensure that the safety margins are largely respected. Therefore, the PARET model for this TRIGA reactor that was previously developed and combined with the MCNP transport code in order to calculate the 3-D temperature distribution in the core and all the most important parameters like the axial distribution of DNBR (Departure from Nucleate Boiling Ratio) across the hottest channel. The most important conclusion is that the 12% fuel elements utilization will have no influence on the safety of the reactor while working around 2 MW power especially for configurations based on insertions in C and D-rings

  4. The Boron Neutron Capture Therapy (BNCT) Project at the TRIGA Reactor in Mainz, Germany

    DEFF Research Database (Denmark)

    Hampel, G.; Grunewald, C.; Schütz, C.

    2011-01-01

    The thermal column of the TRIGA reactor in Mainz is being used very effectively for medical and biological applications. The BNCT (boron neutron capture therapy) project at the University of Mainz is focussed on the treatment of liver tumours, similar to the work performed at Pavia (Italy) a few ...

  5. PUSPATI Triga Reactor pulsing parameters

    Energy Technology Data Exchange (ETDEWEB)

    Auu, Gui Ah; Abu, Puad Haji; Yunus, Yaziz [PUSPATI, Selangor (Malaysia)

    1984-06-01

    The pulsing experiment was carried out as part of the commissioning activites of PUSPATI TRIGA Reactor (PTR). Several parameters of PTR were deduced from the experiment. It was found that the maximum temperature of the fuel was far below the safety limit when the maximum allowable positive reactivity of $3.00 was inserted into the core. The peak power achieved was 1354 Mw.

  6. PSA application for the scram system of Romanian TRIGA Reactor

    International Nuclear Information System (INIS)

    Laslau, Florica; Negut, Gheorghe

    2008-01-01

    The paper is dedicated to the fault tree analysis of the scram system in TRIGA-INR Pitesti reactor. It is a brief description of the scram system which involves instrumentation, mechanical, electrical,and control devices. The failure criteria considered is fail to drop 5 of 8 control rods. Fault tree was developed using immediate cause principle. The reliability data base used is developed in INR Pitesti based on the IAEA data available. The fault tree was analyzed by an original PC code developed for Romanian PSA program. The dominant for this fault tree appeared to be the human errors. This deserves a sensitivity analysis. If we do not consider the CCF errors contribution, the system computed unavailability is: A = 1.25 · 10 -7 . The failure rate is 1.087 · 10 -2 eV/1000 yr. The mean time between failures is 105 years. Taking in the account roads stuck common cause failure, unavailability will increase by two magnitude orders, A = 3.02 · 10 -5 . We considered this number still provides a reassuring mean time between failures. This value is within the limits accepted by similar scram system studies, but is higher than the value obtained in a similar way for the TRIGA reactor of University of Texas. The reason was the taking into account in our case the human error and CCF

  7. A complete fuel development facility utilizing a dual core TRIGA reactor system

    Energy Technology Data Exchange (ETDEWEB)

    Middleton, A; Law, G C [General Atomic Co., San Diego, CA (United States)

    1974-07-01

    A TRIGA Dual Core Reactor System has been chosen by the Romanian Government as the heart of a new fuel development facility which will be operated by the Romanian Institute for Nuclear Technologies. The Facility, which will be operational in 1976, is an integral part of the Romanian National Program for Power Reactor Development, with particular emphasis being placed on fuel development. The unique combination of a new 14 MW steady state TRIGA reactor, and the well-proven TRIGA Annular Core Pulsing Reactor (ACPR) in one below-ground reactor pool resulted in a substantial construction cost savings and gives the facility remarkable experimental flexibility. The inherent safety of the TRIGA fuel elements in both reactor cores means that a secondary containment building is not necessary, resulting in further construction cost savings. The 14 MW steady state reactor gives acceptably high neutron fluxes for long- term testing of various prototype fuel-cladding-coolant combinations; and the TRIGA ACPR high pulse capability allows transient testing of fuel specimens, which is so important for accurate prediction of the performance of power reactor fuel elements under postulated failure conditions. The 14 MW steady state reactor has one large and three small in-core irradiation loop positions, two large irradiation loop positions adjacent to the core face, and twenty small holes in the beryllium reflector for small capsule irradiation. The power level of 14 MW will yield peak unperturbed thermal neutron fluxes in the central experiment position approaching 3.0 x 10{sup 14} n/cm{sup 2}-sec. The ACPR has one large dry central experimental cavity which can be loaded at pool level through a shielded offset loading tube; a small diameter in-core flux trap; and an in-core pneumatically-operated capsule irradiation position. A peak pulse of 15,000 MW will yield a peak fast neutron flux in the central experimental cavity of about 1.5 x 10{sup 17} n/cm{sup 2}-sec. The pulse width at

  8. Preparation and planning for the replacement of the Oregon State University TRIGA reactor rotary specimen rack assembly

    International Nuclear Information System (INIS)

    Anderson, T.V.; Dodd, B.; Johnson, A.G.; Carpenter, W.T.

    1984-01-01

    Recently there have been a number of indications that the rotating rack may be approaching the end of its useful life. In order to benefit from the experience of other reactors who have removed and replaced their rotating racks, General Atomic (GA) was contacted and previous TRIGA Conference proceedings were scanned. It was determined that a number of facilities, had experienced difficulties with their lazy susans and eventually had to replace them. However, most of the written descriptions of this project were not sufficiently detailed to be of great use. The purpose of this paper is to identify some of the more important questions related to the replacement of our rotating rack assembly and OSU's currently proposed solutions, with a view towards soliciting ideas from other members of the TRIGA reactor community

  9. Twenty years of Triga Mark I reactor use

    International Nuclear Information System (INIS)

    Stasiulevicius, R.; Maretti Junior, F.

    1981-01-01

    This work is a report on the 20 years of activities of the Triga Mark I, research reactor located in Belo Horizonte, Brazil. It contains also a list of publications, details of operation and improvements introduced in the reactor as well as some perspectives for its future. (A.C.A.S.)

  10. The contribution of a small TRIGA university research reactor to nuclear research on an international level

    International Nuclear Information System (INIS)

    Villa, M.; Bastuerk, M.; Boeck, H.

    2002-01-01

    The paper focuses especially on the important results in neutron- and solid state physics and the co-operation between the low power TRIGA reactor with high flux neutron sources in Europe such as the Institute Laue-Langevin (ILL) in Grenoble, the Paul Scherrer Institut (PSI) in Villigen, the Rutherford Appleton Laboratory (RAL) in Didcot and the Research Center Juelich. Experiments are set up for test purposes at the TRIGA reactor and then transferred to the powerful neutron sources. Different new perfect silicon channel-cut and interferometer crystals are prepared and then tested at the Bonse-Hart camera, which is a double crystal (or triple axis) diffractometer and at the interferometer set-up. Historically, the first verification of neutron interferometry at a perfect crystal device has been achieved at the 250 kW TRIGA-reactor in Vienna in the year 1974. Also the co-operation with the PSI and the TU Munich in the field of neutron radiography and neutron tomography and VESTA, an experiment for storing cold neutrons with a wavelength of 6.27A, installed at the pulsed neutron source ISIS at RAL are mentioned. The second topic in this paper focuses on the co-operation in the field of safeguard. Several projects have been carried out during the past years in co-operation with the IAEA such as establishing a gamma spectrum reference catalogue for CdZnTe detectors and tests of safeguard video cameras under neutron irradiation. Further an integrated safeguard surveillance network composed of a video camera, a gamma monitor and a neutron monitor is under development

  11. PUSPATI Triga Reactor pulsing parameters

    International Nuclear Information System (INIS)

    Gui Ah Auu; Puad Haji Abu; Yaziz Yunus

    1984-01-01

    The pulsing experiment was carried out as part of the commissioning activites of PUSPATI TRIGA Reactor (PTR). Several parameters of PTR were deduced from the experiment. It was found that the maximum temperature of the fuel was far below the safety limit when the maximum allowable positive reactivity of $3.00 was inserted into the core. The peak power achieved was 1354 Mw. (author)

  12. License renewal and power upgrade of the Cornell University TRIGA reactor

    International Nuclear Information System (INIS)

    Aderhold, Howard C.

    1984-01-01

    The Cornell Mark II TRIGA reactor has been a principal facility for instruction and research in nuclear science and engineering at Cornell, and it has been extensively used by other departments at Cornell and by nearby universities and industries. Initially the fuel was low hydride, 8.5w/o 19%-enriched, aluminum clad; in 1974 it was changed to high-hydride, stainless-steel-clad. The maximum power has been 100 kW, with pulses to $2, and operation has been on a one-shift demand basis. Annual energy generation of 50 MWH has been typical. Standard features include a 4-inch tangential port and our 6-inch radial ports, a thermal column with hohlraum and vertical access, a central thimble, a 'rabbit', and a set of dry irradiation tubes, replacing the 'Lazy Susan'. The license was renewed and amended in November 1983; the new limits are 500 kW and $3 pulses. Physical changes to the facility included addition of a water-to-water heat exchanger and of a diffuser at the water outlet ∼ 60 cm above the core. The flow rate is 300 liters per minute in the primary (reactor) side of the heat exchanger. The temperature of the chilled water entering the secondary of the exchanger is ∼ 12?C; its flow rate is adjusted by a servo-controlled by-pass valve to maintain the desired range of pool water temperature. Steps taken to go to higher power included rearrangement of fuel elements to increase excess reactivity, recalibration of control rods, and power vs ion chamber current calibrations at successively higher power by comparing the rate of rise of pool temperature with a known rate using electrical heating elements. Steady-state operation has been done up to 480 kW (nominal) but pulsing at the newly allowed higher levels has not been tested as yet

  13. Operations of a TRIGA reactor at a small private liberal arts college

    International Nuclear Information System (INIS)

    Church, L.B.

    1978-01-01

    A small private liberal arts college is not a very representative place to have a TRIGA reactor. Reed is a wholly undergraduate institution with a strong emphasis in the traditional liberal arts and fundamental sciences. Many of the larger state universities provide an excellence in nuclear science which is often presented to students in a somewhat distant manner. By providing a reactor that was immediately accessible to undergraduate students it has been realized that the excitement attendant with nuclear science would be available to them in an immediate hands-on manner

  14. DOE University Reactor Sharing Program. Renewal for 1994--1995

    International Nuclear Information System (INIS)

    Chappas, W.J.; Adams, V.G.

    1994-01-01

    The Department of Energy University Reactor Sharing Program at University of Maryland, College Park (UMCP) has, once again, stimulated a broad use of the reactor facilities by undergraduate and graduate students, visitors, and professionals. Participants are exposed to topics such as nuclear engineering, radiation safety, and nuclear reactor operations. This information is presented through various means including tours, slide presentations, experiments, and discussions. Student research using the MUTR is also encouraged. In addition, the Reactor Sharing Program here at the University of Maryland does not limit itself to the confines of the TRIGA reactor facility. Incorporated in the program are the Maryland University Neutron Activation Analysis Laboratory, the Maryland University Radiation Effects Laboratory, and the UMCP 2x4 Thermal Hydraulic Loop. These facilities enhance and give an added dimension to the tours and experiments

  15. Static measurements at PUSPATI TRIGA Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Syed Nahar Bin Syed Hussin Shabuddin; Sharifuldin Bin Salleh, Mohd Amin; Harasawa, Susumu

    1985-06-01

    Static measurements at the PUSPATI TRIGA Reactor (RTP) were made to study the variation of its fuel temperature with reactor power. Some constants that relate power to fuel temperature behaviour were also determined. These constants are reflective of the coolling characteristics in the reactor core. Comparison was also made between the negative temperature coefficient of reactivity obtained from these measurements to those published in the Safety Analysis Report, SAR. The differences between these values are attributable to a delayed effect found in static measurements but not included in the SAR calculation which consider the prompt effect only.

  16. Role of decommissioning plan and its progress for the PUSPATI TRIGA Reactor

    International Nuclear Information System (INIS)

    Zakaria, Norasalwa; Mustafa, Muhammad Khairul Ariff; Anuar, Abul Adli; Idris, Hairul Nizam; Ba'an, Rohyiza

    2014-01-01

    Malaysian nuclear research reactor, the PUSPATI TRIGA Reactor, reached its first criticality in 1982, and since then, it has been serving for more than 30 years for training, radioisotope production and research purposes. Realizing the age and the need for its decommissioning sometime in the future, a ground basis of assessment and an elaborative project management need to be established, covering the entire process from termination of reactor operation to the establishment of final status, documented as the Decommissioning Plan. At international level, IAEA recognizes the absence of Decommissioning Plan as one of the factors hampering progress in decommissioning of nuclear facilities in the world. Throughout the years, IAEA has taken initiatives and drawn out projects in promoting progress in decommissioning programmes, like CIDER, DACCORD and R2D2P, for which Malaysia is participating in these projects. This paper highlights the concept of Decommissioning plan and its significances to the Agency. It will also address the progress, way forward and challenges faced in developing the Decommissioning Plan for the PUSPATI TRIGA Reactor. The efforts in the establishment of this plan helps to provide continual national contribution at the international level, as well as meeting the regulatory requirement, if need be. The existing license for the operation of PUSPATI TRIGA Reactor does not impose a requirement for a decommissioning plan; however, the renewal of license may call for a decommissioning plan to be submitted for approval in future

  17. Role of decommissioning plan and its progress for the PUSPATI TRIGA Reactor

    International Nuclear Information System (INIS)

    Norasalwa Zakaria; Muhammad Khairul Ariff Mustafa; Abul Adli Anuar; Hairul Nizam Idris; Rohyiza Baan

    2013-01-01

    Full-text: Malaysian nuclear research reactor, the PUSPATI TRIGA Reactor, reached its first criticality in 1982, and since then, it has been serving for more than 30 years for training, radioisotope production and research purposes. Realizing the age and the need for its decommissioning sometime in the future, a ground basis of assessment and an elaborative project management need to be established, covering the entire process from termination of reactor operation to the establishment of final status, documented as the Decommissioning Plan. At international level, IAEA recognizes the absence of Decommissioning Plan as one of the factors hampering progress in decommissioning of nuclear facilities in the world. Throughout the years, IAEA has taken initiatives and drawn out projects in promoting progress in decommissioning programmes, like CIDER, DACCORD and R2D2P, for which Malaysia is participating in these projects. This paper highlights the concept of Decommissioning plan and its significances to the Agency. It will also address the progress, way forward and challenges faced in developing the Decommissioning Plan for the PUSPATI TRIGA Reactor. The efforts in the establishment of this plan helps to provide continual national contribution at the international level, as well as meeting the regulatory requirement, if need be. The existing license for the operation of PUSPATI TRIGA Reactor does not impose a requirement for a decommissioning plan; however, the renewal of license may call for a decommissioning plan to be submitted for approval in future. (author)

  18. Role of decommissioning plan and its progress for the PUSPATI TRIGA Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Zakaria, Norasalwa, E-mail: norasalwa@nuclearmalaysia.gov.my; Mustafa, Muhammad Khairul Ariff, E-mail: norasalwa@nuclearmalaysia.gov.my; Anuar, Abul Adli, E-mail: norasalwa@nuclearmalaysia.gov.my; Idris, Hairul Nizam, E-mail: norasalwa@nuclearmalaysia.gov.my; Ba' an, Rohyiza, E-mail: norasalwa@nuclearmalaysia.gov.my [Malaysian Nuclear Agency, 43000 Kajang, Selangor (Malaysia)

    2014-02-12

    Malaysian nuclear research reactor, the PUSPATI TRIGA Reactor, reached its first criticality in 1982, and since then, it has been serving for more than 30 years for training, radioisotope production and research purposes. Realizing the age and the need for its decommissioning sometime in the future, a ground basis of assessment and an elaborative project management need to be established, covering the entire process from termination of reactor operation to the establishment of final status, documented as the Decommissioning Plan. At international level, IAEA recognizes the absence of Decommissioning Plan as one of the factors hampering progress in decommissioning of nuclear facilities in the world. Throughout the years, IAEA has taken initiatives and drawn out projects in promoting progress in decommissioning programmes, like CIDER, DACCORD and R2D2P, for which Malaysia is participating in these projects. This paper highlights the concept of Decommissioning plan and its significances to the Agency. It will also address the progress, way forward and challenges faced in developing the Decommissioning Plan for the PUSPATI TRIGA Reactor. The efforts in the establishment of this plan helps to provide continual national contribution at the international level, as well as meeting the regulatory requirement, if need be. The existing license for the operation of PUSPATI TRIGA Reactor does not impose a requirement for a decommissioning plan; however, the renewal of license may call for a decommissioning plan to be submitted for approval in future.

  19. Analysis of gamma heating at TRIGA mark reactor core Bandung using plate type fuel

    International Nuclear Information System (INIS)

    Setiyanto; Tukiran Surbakti

    2016-01-01

    In accordance with the discontinuation of TRIGA fuel element production by its producer, the operation of all TRIGA type reactor of at all over the word will be disturbed, as well as TRIGA reactor in Bandung. In order to support the continuous operation of Bandung TRIGA reactor, a study on utilization of fuel plate mode, as used at RSG-GAS reactor, to replace the cylindrical model has been done. Various assessments have been done, including core design calculation and its safety aspects. Based on the neutronic calculation, utilization of fuel plate shows that Bandung TRIGA reactor can be operated by 20 fuel elements only. Compared with the original core, the new reactor core configuration is smaller and it results in some empty space that can be used for in-core irradiation facilities. Due to the existing of in-core irradiation facilities, the gamma heating value became a new factor that should be evaluated for safety analysis. For this reason, the gamma heating for TRIGA Bandung reactor using fuel plate was calculated by Gamset computer code. The calculations based on linear attenuation equations, line sources and gamma propagation on space. Calculations were also done for reflector positions (Lazy Susan irradiation facilities) and central irradiation position (CIP), especially for any material samples. The calculation results show that gamma heating for CIP is significantly important (0.87 W/g), but very low value for Lazy Susan position (lest then 0.11 W/g). Based on this results, it can be concluded that the utilization of CIP as irradiation facilities need to consider of gamma heating as data for safety analysis report. (author)

  20. Physics and kinetics of TRIGA reactor

    International Nuclear Information System (INIS)

    Boeck, H.; Villa, M.

    2007-01-01

    This training module is written as an introduction to reactor physics for reactor operators. It assumes the reader has a basic, fundamental knowledge of physics, materials and mathematics. The objective is to provide enough reactor theory knowledge to safely operate a typical research reactor. At this level, it does not necessarily provide enough information to evaluate the safety aspects of experiment or non-standard operation reviews. The material provides a survey of basic reactor physics and kinetics of TRIGA type reactors. Subjects such as the multiplication factor, reactivity, temperature coefficients, poisoning, delayed neutrons and criticality are discussed in such a manner that even someone not familiar with reactor physics and kinetics can easily follow. A minimum of equations are used and several tables and graphs illustrate the text. (author)

  1. Reactor calculations for improving utilization of TRIGA reactor

    International Nuclear Information System (INIS)

    Ravnik, M.

    1986-01-01

    A brief review of our work on reactor calculations of 250 kW TRIGA with mixed core (standard + FLIP fuel) will be presented. The following aspects will be treated: - development of computer programs; - optimization of in-core fuel management with respect to fuel costs and irradiation channels utilization. TRIGAP programme package will be presented as an example of computer programs. It is based on 2-group 1-D diffusion approximation and besides calculations offers possibilities for operational data logging and fuel inventory book-keeping as well. It is developed primarily for the research reactor operators as a tool for analysing reactor operation and fuel management. For this reason it is arranged for a small (PC) computer. Second part will be devoted to reactor physics properties of the mixed cores. Results of depletion calculations will be presented together with measured data to confirm some general guidelines for optimal mixed core fuel management. As the results are obtained using TRIGAP program package results can be also considered as an illustration and qualification for its application. (author)

  2. Control console conceptual design for sheet type fuels of Triga Mark-II reactor

    International Nuclear Information System (INIS)

    Eko Priyono; Kurnia Wibowo; Anang Susanto

    2016-01-01

    The control console conceptual design for sheet type fuel of TRIGA Mark-II reactor has been made. The control console conceptual design was made with refer study result of instrument and control system which is used in BATAN'S reactor i.e TRIGA-2000 Bandung, TRIGA Yogyakarta and MPR-30 Serpong. The control console conceptual design was made by using AutoCad software. The control console conceptual design reactor for sheet type fuel of TRIGA Mark-II reactor consist of 5 segments that is 3 segments for placing the computer monitors, 1 segment for placing bargraph displays and recorders and 1 segment for placing panel meters. There are the door on front and back position at each segment for enter and out devices in the console. The control console conceptual design is also equipped by the table along in front of console for placing reactor panel control and for writing, 3 drawers for 3 keyboards. The dimension of console will refer control room size and the components will be placed on console which will be detailed in detail design if this conceptual design has been approved. (author)

  3. Calibration of A Prompt Gamma Neutron Activation Analysis (PGNAA) Facility: Experience at the Oregon State University TRIGA Reactor

    International Nuclear Information System (INIS)

    Norlida Yussup

    2011-01-01

    A prompt gamma neutron activation analysis (PGNAA) facility at Oregon State University (OSU) TRIGA reactor has been built in year 2008 and been operated since then. PGNAA is a technique used to determine the presence and quantity of trace elements such as boron, hydrogen and carbon which are more difficult to detect with other neutron analysis method. A calibration is essential to ensure the system works as required and the output is valid and reliable. The calibration was carried out by using Standard Reference Material (SRM). Besides, background data was also acquired for comparisons and analysis. The results are analyzed and discussed in this paper. (author)

  4. ANALYSIS OF GAMMA HEATING AT TRIGA MARK REACTOR CORE BANDUNG USING PLATE TYPE FUEL

    Directory of Open Access Journals (Sweden)

    Setiyanto Setiyanto

    2016-10-01

    Full Text Available ABSTRACT In accordance with the discontinuation of TRIGA fuel element production by its producer, the operation of all TRIGA type reactor of at all over the word will be disturbed, as well as TRIGA reactor in Bandung. In order to support the continuous operation of Bandung TRIGA reactor, a study on utilization of fuel plate mode, as used at RSG-GAS reactor, to replace the cylindrical model has been done. Various assessments have been done, including core design calculation and its safety aspects. Based on the neutronic calculation, utilization of fuel plate shows that Bandung TRIGA reactor can be operated by 20 fuel elements only. Compared with the original core, the new reactor core configuration is smaller and it results in some empty space that can be used for in-core irradiation facilities. Due to the existing of in-core irradiation facilities, the gamma heating value became a new factor that should be evaluated for safety analysis. For this reason, the gamma heating for TRIGA Bandung reactor using fuel plate was calculated by Gamset computer code. The calculations based on linear attenuation equations, line sources and gamma propagation on space. Calculations were also done for reflector positions (Lazy Susan irradiation facilities and central irradiation position (CIP, especially for any material samples. The calculation results show that gamma heating for CIP is significantly important (0,87 W/g, but very low value for Lazy Susan position (lest then 0,11 W/g. Based on this results, it can be concluded that the utilization of CIP as irradiation facilities need to consider of gamma heating as data for safety analysis report. Keywords: gamma heating, nuclear reactor, research reactor, reactor safety.   ABSTRAK Dengan dihentikannya produksi elemen bakar reaktor jenis Triga oleh produsen, maka semua reaktor TRIGA di dunia terganggu operasinya, termasuk juga reaktor TRIGA 2000 di Bandung. Untuk mendukung pengoperasian reaktor TRIGA Bandung

  5. Conceptual design of control rod regulating system for plate type fuels of Triga-2000 reactor

    International Nuclear Information System (INIS)

    Eko Priyono; Saminto

    2016-01-01

    Conceptual design of the control rod regulating system for plate type fuel of TRIGA-2000 reactor has been made. Conceptual design of the control rod regulating system for plate type fuel of TRIGA-2000 reactor was made with refer to study result of instrument and control system which is used in BATAN'S reactor. Conceptual design of the control rod regulating system for plate type fuel of TRIGA-2000 reactor consist of 4 segments that is control panel, translator, driver and display. Control panel is used for regulating, safety and display control rod, translator is used for signal processing from control panel, driver is used for driving control rod and display is used for display control rod level position. The translator was designed in 2 modes operation i.e operation by using PLC modules and IC TTL modules. These conceptual design can be used as one of reference of control rod regulating system detail design. (author)

  6. Performances on nuclear activation analysis by TRIGA Mark II reactor

    International Nuclear Information System (INIS)

    Capannesi, G.; Rosada, A.

    1986-01-01

    Progresses in methodological research and connected applications in the field of activation analysis are introduced. Some peculiar characteristics on the TRIGA MARK II reactor have enabled the possibility of obtaining interesting results. The particular, the rotating radiation device Lazy Susan, with a capability of 40 positionings, permits homogeneity in neutron flux and energy spectrum stability within 15%. High level of precision and accuracy are obtained in analytic. Applications of major interest have been: - reference material certification; - forensic applications; - electrolytic cell productivity evaluation. The TRIGA MARK II reactor is equipped with a thermal column throughout a D 2 O diaphragm with a thickness of 70 cm. The available neutron flux has no fast and epithermal components. Via this facility a method has been tested for the instrumental determination of Al in Si metal of solar and electronic degree. (author)

  7. Operation and maintenance experience at the General Atomic Company's TRIGA reactor facility at San Diego, California

    International Nuclear Information System (INIS)

    Whittemore, W.L.; Stout, W.A.; Shoptaugh, J.R.; Chesworth, R.H.

    1982-01-01

    Since the startup of the original 250 kW TRIGA Mark I reactor in 1958, General Atomic Company has accumulated nearly 24 years of operation and maintenance experience with this type of reactor. In addition to the nearly 24 years of experience gained on the Mark I, GA has operated the 1.5 MW Advanced Prototype Test Reactor (Mark F) for 22 years and operated a 2 MW below-ground TRIGA Mark III for five years. Information obtained from normal and abnormal operation are presented. (author)

  8. Fuel management for TRIGA reactor operators

    International Nuclear Information System (INIS)

    Totenbier, R.E.; Levine, S.H.

    1980-01-01

    One responsibility of the Supervisor of Reactor Operations is to follow the TRIGA core depletion and recommend core loading changes for refueling and special experiments. Calculations required to analyze such changes normally use digital computers and are extremely difficult to perform for one who is not familiar with computer language and nuclear reactor diffusion theory codes. The TRICOM/SCRAM program developed to perform such calculations for the Penn State TRIGA Breazeale Reactor (PSBR), has a very simple input format and is one which can be used by persons having no knowledge of computer codes. The person running the program need not understand computer language such as Fortran, but should be familiar with reactor core geometry and effects of loading changes. To further simplify the input requirements but still allow for all of the studies normally needed by the reactor operations supervisor, the options required for input have been isolated to two. Given a master deck of computer cards one needs to change only three cards; a title card, core energy history information card and one with core changes. With this input, the program can provide individual fuel element burn-up for a given period of operation and the k eff of the core. If a new loading is desired, a new master deck containing the changes is also automatically provided. The life of a new core loading can be estimated by feeding in projected core burn-up factors and observing the resulting loss in individual fuel elements. The code input and output formats have now been made sufficiently convenient and informative as to be incorporated into a standard activity for the Reactor Operations Supervisor. (author)

  9. Startup of Torrey Pines Mark III and Puerto Rico Nuclear Center reactors with TRIGA-FLIP fuel

    Energy Technology Data Exchange (ETDEWEB)

    Chesworth, R. H. [Gulf E and ES, San Diego, CA (United States)

    1972-07-01

    This paper discusses the characteristics of TRIGA FLIP cores in two different geometries: the normal TRIGA single-rod geometry as typified by the installation in the Torrey Pines Mark III reactor; and the four-rod cluster geometry as typified by the conversion core installed in the Puerto Rico Nuclear Center reactor at Mayaguez. In both reactors the fuel is 8-1/2 wt % uranium, 70% enriched in U-235. The hydrogen to zirconium atom ratio is 1.5 to 1.65 and the cladding material is stainless steel. The basic neutronic characteristics of the fuel in both reactor installations are briefly discussed.

  10. United States Domestic Research Reactor Infrastructure - TRIGA Reactor Fuel Support

    International Nuclear Information System (INIS)

    Morrell, Douglas

    2008-01-01

    The purpose of the United State Domestic Research Reactor Infrastructure Program is to provide fresh nuclear reactor fuel to United States universities at no, or low, cost to the university. The title of the fuel remains with the United States government and when universities are finished with the fuel, the fuel is returned to the United States government. The program is funded by the United States Department of Energy - Nuclear Energy division, managed by Department of Energy - Idaho Field Office, and contracted to the Idaho National Laboratory's Management and Operations Contractor - Battelle Energy Alliance. Program has been at Idaho since 1977 and INL subcontracts with 26 United States domestic reactor facilities (13 TRIGA facilities, 9 plate fuel facilities, 2 AGN facilities, 1 Pulstar fuel facility, 1 Critical facility). University has not shipped fuel since 1968 and as such, we have no present procedures for shipping spent fuel. In addition: floor loading rate is unknown, many interferences must be removed to allow direct access to the reactor tank, floor space in the reactor cell is very limited, pavement ends inside our fence; some of the surface is not finished. The whole approach is narrow, curving and downhill. A truck large enough to transport the cask cannot pull into the lot and then back out (nearly impossible / refused by drivers); a large capacity (100 ton), long boom crane would have to be used due to loading dock obstructions. Access to the entrance door is on a sidewalk. The campus uses it as a road for construction equipment, deliveries and security response. Large trees are on both sides of sidewalk. Spent fuel shipments have never been done, no procedures approved or in place, no approved casks, no accident or safety analysis for spent fuel loading. Any cask assembly used in this facility will have to be removed from one crane, moved on the floor and then attached to another crane to get from the staging area to the reactor room. Reactor

  11. Utilization of Slovenian TRIGA Mark II reactor

    International Nuclear Information System (INIS)

    Snoj, L.; Smodis, B.

    2010-01-01

    TRIGA Mark II research reactor at the Jozef Stefan Institute [JSI] is extensively used for various applications, such as: irradiation of various samples, training and education, verification and validation of nuclear data and computer codes, testing and development of experimental equipment used for core physics tests at a nuclear power plant. The paper briefly describes the aforementioned activities and shows that even such small reactors are still indispensable in nuclear science and technology. (author)

  12. Small Angle Neutron Scattering instrument at Malaysian TRIGA reactor

    Energy Technology Data Exchange (ETDEWEB)

    Mohd, Shukri; Kassim, Razali; Mahmood, Zal Uyun [Malaysian Inst. for Nuclear Technology Research (MINT), Bangi, Kajang (Malaysia); Radiman, Shahidan

    1998-10-01

    The TRIGA MARK II Research reactor at the Malaysian Institute for Nuclear Research (MINT) was commissioned in July 1982. Since then various works have been performed to utilise the neutrons produced from this steady state reactor. One of the project involved the Small Angle Neutron Scattering (SANS). (author)

  13. Operation and maintenance experiences at the C.R.E. Casaccia TRIGA reactor

    International Nuclear Information System (INIS)

    Festinesi, A.

    1988-01-01

    The memoir explains TRIGA RC-1 plant activities from last European TRIGA Users' Conference till today. In particular, measures following reactor exercise license renewing (March 1987) are described. Finally, difficulties and measures about shielding tank's water funguses and spores contamination, are explained. (author)

  14. Current research work at the TRIGA reactor in Ljubljana

    International Nuclear Information System (INIS)

    Najzer, M.; Dimic, V.

    1978-01-01

    The research programmes at this TRIGA reactor cover quite broad and different research fields. They can be grouped in the following topics: reactor dynamics and operation, neutron activation analysis, solid state physics research, reactor dosimetry, radiography and fuel burn-up determination. In this presentation a short overview is given of those investigations which are not described in detail in separate papers

  15. Neutron flux measurements in PUSPATI Triga Reactor

    International Nuclear Information System (INIS)

    Gui Ah Auu; Mohamad Amin Sharifuldin Salleh; Mohamad Ali Sufi.

    1983-01-01

    Neutron flux measurement in the PUSPATI TRIGA Reactor (PTR) was initiated after its commissioning on 28 June 1982. Initial measured thermal neutron flux at the bottom of the rotary specimen rack (rotating) and in-core pneumatic terminus were 3.81E+11 n/cm 2 sec and 1.10E+12n/cm 2 sec respectively at 100KW. Work to complete the neutron flux data are still going on. The cadmium ratio, thermal and epithermal neutron flux are measured in the reactor core, rotary specimen rack, in-core pneumatic terminus and thermal column. Bare and Cadmium covered gold foils and wires are used for the above measurement. The activities of the irradiated gold foils and wires are determined using Ge(Li) and hyperpure germinium detectors. (author)

  16. Reactor physics tests of TRIGA Mark-II Reactor in Ljubljana

    International Nuclear Information System (INIS)

    Ravnik, M.; Mele, I.; Trkov, A.; Rant, J.; Glumac, B.; Dimic, V.

    2008-01-01

    TRIGA Mark-II Reactor in Ljubljana was recently reconstructed. The reconstruction consisted mainly of replacing the grid plates, the control rod mechanisms and the control unit. The standard type control rods were replaced by the fuelled follower type, the central grid location (A ring) was adapted for fuel element insertion, the triangular cutouts were introduced in the upper plate design. However, the main novelty in reactor physics and operational features of the reactor was the installation of a pulse rod. Having no previous operational experience in pulsing, a detailed and systematic sequence of tests was defined in order to check the predicted design parameters of the reactor with measurements. The following experiments are treated in this paper: initial criticality, excess reactivity measurements, control rod worth measurement, fuel temperature distribution, fuel temperature reactivity coefficient, pulse parameters measurement (peak power, prompt energy, peak temperature). Flux distributions in steady state and pulse mode were measured as well, however, they are treated only briefly due to the volume of the results. The experiments were performed with completely fresh fuel of 12 w% enriched Standard Stainless Steel type. The core configuration was uniform (one fuel element type, including fuelled followers) and compact (no irradiation channels or gaps), as such being particularly convenient for testing the computer codes for TRIGA reactor calculations. Comparison of analytical predictions, obtained with WIMS, SLXTUS, TRIGAP and PULSTRI codes to measured values showed agreement within the error of the measurement and calculation. The paper has the following contents: 1. Introduction; 2. Steady State Experiments; 2.1. Core loading and critical experiment; 2.2. Flux range determination for tests at zero power; 2.3. Digital reactivity meter checkout; 2.4. Control rod worth measurements; 2.5. Excess reactivity measurement; 2.6. Thermal power calibration; 2

  17. Optimization study of ultracold neutron sources at TRIGA reactors using MCNP

    International Nuclear Information System (INIS)

    Pokotilovskij, Yu.N.; Rogov, A.D.

    1997-01-01

    Monte Carlo simulation for the optimization of ultracold and very cold neutron sources for TRIGA reactors is performed. The calculations of thermal and cold neutron fluxes from the TRIGA reactor for different positions and configurations of a very cold solid methane moderator were performed with using the MCNP program. The production of neutrons in the ultracold and very cold energy range was calculated for the most promising final moderators (converters): very cold solid deuterium and heavy methane. The radiation energy deposition was calculated for the optimized solid methane-heavy methane cold neutron moderator

  18. The role of TRIGA reactors in pure and applied nuclear research outside the United States in the last couple of years

    International Nuclear Information System (INIS)

    Rollier, M.A.

    1972-01-01

    The last two years trend of research in European TRIGA plants, which reported to the 1970 TRIGA Owners' Conference in Helsinki, is presented. The report discusses also new TRIGA plants in Europe, 1971-72; Research at TRIGA plants and new TRIGA reactors outside Europe and the U.S.A., 1971-72; Safety, health, environment, egomania and TRIGA reactors

  19. The contribution of a small triga university research reactor to nuclear research on an international level

    International Nuclear Information System (INIS)

    Villa, M.; Boeck, H.; Weber, H.W.

    2001-01-01

    The paper focuses especially on the important results in neutron- and solid state physics and the co-operation between the low power TRIGA reactor with high flux neutron sources in Europe such as the Institute Laue-Langevin (ILL) in Grenoble, the Paul Scherrer Institut (PSI) in Villigen, the Rutherford Appleton Laboratory (RAL) in Didcot and the Research Center Juelich. Experiments are set up for test purposes at the TRIGA reactor and then transferred to the powerful neutron sources. Different new perfect silicon channel-cut and interferometer crystals are prepared and then tested at the Bonse-Hart camera, which is a double crystal (or triple axis) diffractometer and at the interferometer set-up. Historically, the first verification of neutron interferometry at a perfect crystal device has been achieved at the 250 kW TRIGA-reactor in Vienna in the year 1974. Also the co-operation with the PSI and the TU Munich in the field of neutron radiography and neutron tomography and VESTA, an experiment for storing cold neutrons with a wavelength of 6.27 A, installed at the pulsed neutron source ISIS at RAL will be mentioned. The second topic treated in this paper shows the international co-operation in the field of superconductors. This research work is carried out under two European TMR-Network programs. The third topic in this paper focuses on the co-operation in the field of safeguard. Several projects have been carried out during the past years in co-operation with the IAEA such as establishing a gamma spectrum reference catalogue for CdZnTe detectors and tests of safeguard video cameras under neutron irradiation. Further an integrated safeguard surveillance network composed of a video camera, a gamma monitor and a neutron monitor is under development. (orig.)

  20. Irradiation routine in the IPR-R1 Triga reactor

    International Nuclear Information System (INIS)

    Maretti Junior, F.

    1980-01-01

    Information about irradiations in the IPR-R1 TRIGA reactor and procedures necessary for radioisotope solicitation are presented All procedures necessary for asking irradiation in the reactor, shielding types, norms of terrestrial and aerial expeditions, payment conditions, and catalogue of disposable isotopes with their respective saturation activities are described. (M.C.K.)

  1. Design improvements in TRIGA reactors

    International Nuclear Information System (INIS)

    Batch, John M.

    1970-01-01

    There have been many design improvements to TRIGA reactor hardware in the past twelve years. One of the more important and most obvious improvements has been in the area of reactor instrumentation. The low profile, completely transistorized Mark III console was a great step forward in a low maintenance, high reliability instrumentation system. Other design improvements include the lazy susan specimen pickup assembly; the specimen container; an empty stainless steel fuel element which can be filled with samples and can be located anywhere in the core; the flexible fuel handling tool; a new fuel measuring tool design; the shock absorber on the adjustable transient rod drive; new testing and evaluation procedures on the thermocouples and other

  2. Probabilistic safety analysis for the Triga reactor Vienna

    International Nuclear Information System (INIS)

    Boeck, H.; Kirchsteiger, C.

    1988-07-01

    Triga-type reactors are the most widely used low power research reactors with power levels up to 3 MW. Although Triga reactors are considered inherently safe, due to their unique features such as prompt negative temperature coefficient and low power density, the reactor core still contains a respectable amount of activity which could lead under very adverse circumstances to radiation exposure both of staff members and of public. Such circumstances could be external events, accidents during fuel element manipulation or a loss of coolant water with exposure of the core. Therefore, it was decided to look more closely to various accident pathways and to calculate their probability, if possible. A major drawback is the lack of statistical material because no centralized registration of failures is carried out. Therefore, in many cases values from other research reactor types or even from power reactor statistics had to be used, thus increasing the uncertainty of the results. As most undesired event or TOP-event in this analysis a radiation exposure of staff members, the public or both together was selected and the probabilities of different pathways leading to this exposure was calculated. In the present case 'radiation exposure' are dose rates or activity concentration above the international accepted limits for occupational staff or public. 20 refs., 10 figs. (Author)

  3. Operating experience with the Cornell University TRIGA reactor

    International Nuclear Information System (INIS)

    Aderhold, H.C.

    1970-01-01

    As a result of our investigations, we believed the damage to be mechanical in origin and not to cladding failure. A new handling tool of modified design was put into service in July 1963, and since that time one element S/N 3075 has been dropped. This we believe was caused by operator error. At the request of prospective users, a high intensity, high energy gamma-ray irradiation facility has been added to the TRIGA equipment. This apparatus is simple to construct and use, either temporarily or permanently, with the TRIGA. Adjustment of relative neutron and gamma ray fluxes is possible by either shielding or changing rate of water flow. No attempt was made to improve performance by guiding water flow through the core, and higher yields should be obtainable by this means and by increasing the size of the holdup tank

  4. The 10 MW multipurpose TRIGA reactor at Ongkharak Nuclear Research Center, Thailand

    International Nuclear Information System (INIS)

    Thurgood, B.E.; Razvi, J.; Whittemore, J.L.; Bhadrakom, K.

    1997-01-01

    General Atomics (GA), has been selected to lead a team of firms from the United States, Japan, Australia and Thailand to design, build and commission the Ongkharak Nuclear Research Center near Bangkok, Thailand, for the Office of Atomic Energy for Peace. The facilities to be provided comprise of: A Reactor Island, consisting of a 10 MW TRIGA reactor that takes full advantage of the inherent safety characteristics of uranium-zirconium hydride (UZrH) fuel; An Isotope Production Facility for the production of radioisotopes and radiopharmaceuticals using the TRIGA reactor; A Waste Processing and Storage Facility for the processing and storage of radioactive waste from the facility as well as other locations in Thailand. The centerpiece of the Center will be the TRIGA reactor, fueled with low-enriched UZrH fuel, cooled and moderated by light water, and reflected by beryllium and heavy water. The UZrH fueled reactor will have a rated steady state thermal power output of 10 MW, and will be capable of performing the following: Radioisotope production for medical, industrial and agricultural uses; Neutron transmutation doping of silicon; Beam experiments such as Neutron Scattering, Neutron Radiography (NR), and Prompt Gamma Neutron Activation Analysis (PGNAA); Medical therapy of patients using Boron Neutron Capture Therapy (BNCT); Applied research and technology development in the nuclear field; Training in principles of reactor operation, reactor physics, reactor experiments, etc. (author)

  5. Pneumatic transport systems for TRIGA reactors

    International Nuclear Information System (INIS)

    Bolton, John A.

    1970-01-01

    Main parameters and advantages of pneumatically operated systems, primarily those operated by gas pressure are discussed. The special irradiation ends for the TRIGA reactor are described. To give some idea of the complexity of some modern systems, the author presents the large system currently operating at the National Bureau of Standards in Washington. In this system, 13 stations are located throughout the radiochemistry laboratories and three irradiation ends are located in the reactor, which is a 14-megawatt unit. The system incorporates practically every fail-safe device possible, including ball valves located on all capsule lines entering the reactor area, designed to close automatically in the event of a reactor scram, and at that time capsules within the reactor would be diverted by means of switches located on the inside of the reactor wall. The whole system is under final control of a permission control panel located in the reactor control room. Many other safety accessories of the system are described

  6. Refurbishment, Modernization and Ageing Management Program of The 3MW TRIGA Mark-II Research Reactor of Bangladesh

    International Nuclear Information System (INIS)

    Salam, M. A.

    2013-01-01

    by the installation of a high performance neutron powder diffractometer at the radial beam port-2 of the reactor. Although preventive and predictive maintenance, periodic testing, in-service inspection and other mitigation measures were practiced in few systems of the BAEC RR facility, these were not enough to mitigate the ageing related degradation of N-16 decay tank, shell and tube heat exchanger and radial beam port-1. It was understood that if effective ageing management program were started effectively from the beginning of the reactor, refurbishment activities could be minimized. As well as life of the reactor could be enhanced without any hurdle tasks. Basis on these understanding ROMU submitted an IAEA TC Project (BGD1012) titled 'Implementing an Ageing Management Program for RR'. Under this project an effective ageing management program has commenced on January, 2012 for the BAEC RR to enhance life and ensure safe operation of the reactor. This paper will describe chronologically refurbishment activities and experience for different affected systems, required resources and management and lessons learned from these tasks. It will also focus the modernization activities of the reactor facility. Moreover, it will describe ageing management activities that are planned for the BAEC TRIGA MK-II research reactor

  7. Refurbishment, Modernization and Ageing Management Program of The 3MW TRIGA Mark-II Research Reactor of Bangladesh

    Energy Technology Data Exchange (ETDEWEB)

    Salam, M. A. [Atomic Energy Research Establishment, Dhaka (Bangladesh)

    2013-07-01

    by the installation of a high performance neutron powder diffractometer at the radial beam port-2 of the reactor. Although preventive and predictive maintenance, periodic testing, in-service inspection and other mitigation measures were practiced in few systems of the BAEC RR facility, these were not enough to mitigate the ageing related degradation of N-16 decay tank, shell and tube heat exchanger and radial beam port-1. It was understood that if effective ageing management program were started effectively from the beginning of the reactor, refurbishment activities could be minimized. As well as life of the reactor could be enhanced without any hurdle tasks. Basis on these understanding ROMU submitted an IAEA TC Project (BGD1012) titled 'Implementing an Ageing Management Program for RR'. Under this project an effective ageing management program has commenced on January, 2012 for the BAEC RR to enhance life and ensure safe operation of the reactor. This paper will describe chronologically refurbishment activities and experience for different affected systems, required resources and management and lessons learned from these tasks. It will also focus the modernization activities of the reactor facility. Moreover, it will describe ageing management activities that are planned for the BAEC TRIGA MK-II research reactor.

  8. Modernization design of neutron radiography of ITU TRIGA Mark-II reactor

    International Nuclear Information System (INIS)

    Tugrul, B.; Bilge, A.N.

    1988-01-01

    ITU TRIGA MARK-II Research and Training Reactor has a power of 250 KW and has three beam tubes. One of them is tangential beam tube used for neutron radiography. In this study, the neutron radiography set in the tangential beam tube is described with its problems for ITU TRIGA Reactor. After that modernization of the system is designed and the applicability of the direct and indirect methods is evaluated. Improving the ratio of length to diameter for the beam tube, elimination the fogging on the film and constructive design for practice and secure application of the technique is developed. (author)

  9. Decontamination of TRIGA Mark II reactor, Indonesia

    International Nuclear Information System (INIS)

    Suseno, H.; Daryoko, M.; Goeritno, A.

    2002-01-01

    The TRIGA Mark II Reactor in the Centre for Research and Development Nuclear Technique Bandung has been partially decommissioned as part of an upgrading project. The upgrading project was carried out from 1995 to 2000 and is being commissioned in 2001. The decommissioning portion of the project included disassembly of some components of the reactor core, producing contaminated material. This contaminated material (grid plate, reflector, thermal column, heat exchanger and pipe) will be sent to the Decontamination Facility at the Radioactive Waste Management Development Centre. (author)

  10. Flux measurement in ZBR at the TRIGA Mark II reactor

    International Nuclear Information System (INIS)

    Dauke, M.

    2005-01-01

    The determination of the neutron flux in the TRIGA-2-Vienna reactor was the objective of this research. The theory of the method (4π-β detectors) is presented as well as the determination of the maximum flux, gold-cadmium differential measurement, cobalt-wire measurement, finally a comparison of all results was made and interpreted. (nevyjel)

  11. Characterization of gamma field in the JSI TRIGA reactor

    Science.gov (United States)

    Ambrožič, Klemen; Radulović, Vladimir; Snoj, Luka; Gruel, Adrien; Guillou, Mael Le; Blaise, Patrick; Destouches, Christophe; Barbot, Loïc

    2018-01-01

    Research reactors such as the "Jožzef Stefan" Institute TRIGA reactor have primarily been designed for experimentation and sample irradiation with neutrons. However recent developments in incorporating additional instrumentation for nuclear power plant support and with novel high flux material testing reactor designs, γ field characterization has become of great interest for the characterization of the changes in operational parameters of electronic devices and for the evaluation of γ heating of MTR's structural materials in a representative reactor Γ spectrum. In this paper, we present ongoing work on γ field characterization both experimentally, by performing γ field measurements, and by simulations, using Monte Carlo particle transport codes in conjunction with R2S methodology for delayed γ field characterization.

  12. Flow-induced vibration phenomenon in a Mark III TRIGA reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C K; Whittemore, W L; Kim, B S; Lee, J B; Blevins, R D; Burton, T E [Korea Atomic Energy Research Institute, Seoul (Korea, Republic of); General Atomic Company, San Diego, CA (United States)

    1976-07-01

    The Mark III TRIGA reactor with hexagonal fuel spacing is capable of operating at 2.0 MW. The Mark III at San Diego operated without core cooling problems or vibration at power levels up to 2.0 MW. All Mark III reactors have operated trouble-free up to 1.0 MW. The Mark III TRIGA in Korea was installed in 1972 and operated many months without trouble at 2.0 MW. During this period core changes including addition of new fuel were made. Eighteen months after startup, a coolant flow-induced vibration was observed for the first time at a power of 1.5 MW. A lengthy series of tests showed that it was not possible to establish a core configuration that permitted vibration-free operation for power levels in the range 1.5 - 2.0 MW. Observations during the tests confirmed that standing waves in the reactor tank water coupled the source within the core to the shield structure and surrounding building. Analysis of the data indicates strongly that the source of the vibration is the creation and collapse of bubbles with the core acting as a resonator. A substantially increased flow of coolant through the upper grid plate is expected to eliminate the vibration phenomenon and permit trouble-free operation at power up to 2.0 MW. In an attempt to seek a remedy, both GAC and KAERI have independently developed designs for upper grid plates. KAERI has constructed and installed an interim version of the standard grid plate which was calculated to provide 25% more coolant flow and mounted high so as to provide less restriction to flow around the upper fittings of the fuel elements. A substantial reduction in vibration was observed. No vibration was observed at any power up to 2.0 MW with cooling water at or below 20 C. A slight vibration at 1.8 MW occurred for higher cooling temperatures. The GAC grid plate design provides not only for increasing the flow area but also for streamlining the flow surfaces on the grid plate and possibly also on the top fittings of the fuel elements. It is

  13. Flow-induced vibration phenomenon in a Mark III TRIGA reactor

    International Nuclear Information System (INIS)

    Lee, C.K.; Whittemore, W.L.; Kim, B.S.; Lee, J.B.; Blevins, R.D.; Burton, T.E.

    1976-01-01

    The Mark III TRIGA reactor with hexagonal fuel spacing is capable of operating at 2.0 MW. The Mark III at San Diego operated without core cooling problems or vibration at power levels up to 2.0 MW. All Mark III reactors have operated trouble-free up to 1.0 MW. The Mark III TRIGA in Korea was installed in 1972 and operated many months without trouble at 2.0 MW. During this period core changes including addition of new fuel were made. Eighteen months after startup, a coolant flow-induced vibration was observed for the first time at a power of 1.5 MW. A lengthy series of tests showed that it was not possible to establish a core configuration that permitted vibration-free operation for power levels in the range 1.5 - 2.0 MW. Observations during the tests confirmed that standing waves in the reactor tank water coupled the source within the core to the shield structure and surrounding building. Analysis of the data indicates strongly that the source of the vibration is the creation and collapse of bubbles with the core acting as a resonator. A substantially increased flow of coolant through the upper grid plate is expected to eliminate the vibration phenomenon and permit trouble-free operation at power up to 2.0 MW. In an attempt to seek a remedy, both GAC and KAERI have independently developed designs for upper grid plates. KAERI has constructed and installed an interim version of the standard grid plate which was calculated to provide 25% more coolant flow and mounted high so as to provide less restriction to flow around the upper fittings of the fuel elements. A substantial reduction in vibration was observed. No vibration was observed at any power up to 2.0 MW with cooling water at or below 20 C. A slight vibration at 1.8 MW occurred for higher cooling temperatures. The GAC grid plate design provides not only for increasing the flow area but also for streamlining the flow surfaces on the grid plate and possibly also on the top fittings of the fuel elements. It is

  14. TRIGA reactor operating experience

    International Nuclear Information System (INIS)

    Anderson, T.V.

    1970-01-01

    The Oregon State TRIGA Reactor (OSTR) has been in operation 3 years. Last August it was upgraded from 250 kW to 1000 kW. This was accomplished with little difficulty. During the 3 years of operation no major problems have been experienced. Most of the problems have been minor in nature and easily corrected. They came from lazy susan (dry bearing), Westronics Recorder (dead spots in the range), The Reg Rod Magnet Lead-in Circuit (a new type lead-in wire that does not require the lead-in cord to coil during rod withdrawal hss been delivered, much better than the original) and other small corrections

  15. Neutron flux and gamma dose measurement in the BNCT irradiation facility at the TRIGA reactor of the University of Pavia

    Science.gov (United States)

    Bortolussi, S.; Protti, N.; Ferrari, M.; Postuma, I.; Fatemi, S.; Prata, M.; Ballarini, F.; Carante, M. P.; Farias, R.; González, S. J.; Marrale, M.; Gallo, S.; Bartolotta, A.; Iacoviello, G.; Nigg, D.; Altieri, S.

    2018-01-01

    University of Pavia is equipped with a TRIGA Mark II research nuclear reactor, operating at a maximum steady state power of 250 kW. It has been used for many years to support Boron Neutron Capture Therapy (BNCT) research. An irradiation facility was constructed inside the thermal column of the reactor to produce a sufficient thermal neutron flux with low epithermal and fast neutron components, and low gamma dose. In this irradiation position, the liver of two patients affected by hepatic metastases from colon carcinoma were irradiated after borated drug administration. The facility is currently used for cell cultures and small animal irradiation. Measurements campaigns have been carried out, aimed at characterizing the neutron spectrum and the gamma dose component. The neutron spectrum has been measured by means of multifoil neutron activation spectrometry and a least squares unfolding algorithm; gamma dose was measured using alanine dosimeters. Results show that in a reference position the thermal neutron flux is (1.20 ± 0.03) ×1010 cm-2 s-1 when the reactor is working at the maximum power of 250 kW, with the epithermal and fast components, respectively, 2 and 3 orders of magnitude lower than the thermal component. The ratio of the gamma dose with respect to the thermal neutron fluence is 1.2 ×10-13 Gy/(n/cm2).

  16. Aspects of intellectual property related to the TRIGA reactor in Romania

    International Nuclear Information System (INIS)

    Chirita, Ion

    2008-01-01

    Full text: A TRIGA - type research reactor has been operating in Pitesti since 1979. In Romania, the first research reactor - of the WWR-C type - has been operating since 1957. Both these reactors have contributed to the formation of well - trained specialists, whose works constitute an important intellectual and industrial property. Institute for Nuclear Research (formerly INT, then INPR) is the holder of several published patents, such as: Procedure for decontamination of water and primary circuits of irradiation devices; Reconditioning of ion exchangers; Nozzle for flow water gaugers; Oscillating electromagnetic pump; Facility for determining nuclear fuel burnup; Portable monitor for contamination measurements; Cable joints with biological protection; Anti-seismic and thermal connection; Automatic facility for nuclear fuel irradiation testing; Method for determining power distribution specific for research rector fuel elements; Tight end-fittings; Cooling damage facility, etc. Many of these have been applied or can be applied to reactors of the TRIGA family or are already installed or under installation to research reactors of other types. (authors)

  17. Effluent releases at the TRIGA reactor facility

    Energy Technology Data Exchange (ETDEWEB)

    Whittemore, W L [General Atomic Co., San Diego, CA (United States)

    1974-07-01

    The principal effluent from the operating TRIGA reactors in our facility is argon-41. As monitored by a recording gas and particulate stack monitor, the values shown in the table, the Mark III operating 24 hours per day for very long periods produced the largest amount of radioactive argon. The quantity of 23.7 Ci A-41 when diluted by the normal reactor room ventilation system corresponded to 1.45 x 10{sup -6} {mu}Ci/cc. As diluted in the roof stack stream and the reactor building wake, the concentration immediately outside the reactor building was 25% MPC for an unrestricted area. The continued dilution of this effluent resulted in a concentration of a few percent MPC at the site boundary (unrestricted area) 350 meters from the reactor. (author)

  18. Research activities at the TRIGA Mainz

    International Nuclear Information System (INIS)

    Eberhardt, K.; Trautmann, N.

    2002-01-01

    The TRIGA Mark II reactor of the Mainz University became first critical on August 3, 1965. It can be operated in the steady state mode with a maximum power of 100 kW and in the pulse mode with a peak power of 250 MW. The TRIGA Mainz is mainly used for neutron activation analysis, isotope production, basic research in nuclear chemistry and nuclear physics as well as for education and training

  19. Computer codes used during upgrading activities at MINT TRIGA reactor

    International Nuclear Information System (INIS)

    Mohammad Suhaimi Kassim; Adnan Bokhari; Mohd Idris Taib

    1999-01-01

    MINT TRIGA Reactor is a 1-MW swimming pool nuclear research reactor commissioned in 1982. In 1993, a project was initiated to upgrade the thermal power to 2 MW. The IAEA assistance was sought to assist the various activities relevant to an upgrading exercise. For neutronics calculations, the IAEA has provided expert assistance to introduce the WIMS code, TRIGAP, and EXTERMINATOR2. For thermal-hydraulics calculations, PARET and RELAP5 were introduced. Shielding codes include ANISN and MERCURE. However, in the middle of 1997, MINT has decided to change the scope of the project to safety upgrading of the MINT Reactor. This paper describes some of the activities carried out during the upgrading process. (author)

  20. Experiments utilizing two coupled TRIGA-type reactors

    Energy Technology Data Exchange (ETDEWEB)

    Thayer, G [Southern California Edison Co., Rosemead, CA (United States); Jones, B G; Miley, G H [University of Illinois (United States)

    1974-07-01

    An experimental study has been performed on a coupled-core system consisting of two reactors each of which can be made critical by itself, coupled neutronically by a graphite thermal column. Both steady-state and transient measurements were performed on the system. The steady-state measurement consisted of measuring the coupling coefficient between the two reactors. Also, series of measurements were performed while one of the cores was far subcritical and the coupling between the two cores was varied between 1.6 x 10{sup -2} and 1.6 x 10{sup -5} cents by the insertion of a water gap and from 1.6 x 10{sup -2} cents to 6.0 x 10{sup -4} cents by the insertion of a cadmium sheet between the cores. The transient portion of the study was performed by pulsing one of the reactors (the Illinois Advanced TRIGA) and following the pulse into the passive core (the Low Power Reactor Assembly). The first pulse series measured the pulse as it emerged from the thermal column and propagated through the water, where no fuel was present. This provided an analysis of the neutron source to the passive core. The second pulse series was performed with the passive core far subcritical (k{sub eff} {approx_equal} 0.94) and investigated the effects on the transient coupling of the insertion of water gaps of up to 9 inches or a cadmium sheet ({sigma}T = 3.2) between the two cores. Spatial measurements of the pulse in the far subcritical assembly also were performed. The third series of pulses investigated the characteristics of the pulse in the passive core when it was subcritical, just critical, and supercritical, The effects on the FWHM of the pulse in the passive core and on the delay time between the peak of the pulse in the TRIGA and the passive core were measured for the passive core having a k{sub eff} from 0.936 to 1.0015 and the initial period of the pulse in TRIGA varying from 15.6 {+-} .7 ms to 3.58 {+-} .05 ms. The FWHM increased from 13.5 {+-} 0.5 ms to 18.8 {+-} 0.5 ms and delay

  1. Calculation of fuel element temperature TRIGA 2000 reactor in sipping test tubes using CFD

    International Nuclear Information System (INIS)

    Sudjatmi KA

    2013-01-01

    It has been calculated the fuel element temperature in the sipping test of Bandung TRIGA 2000 reactor. The calculation needs to be done to ascertain that the fuel element temperatures are below or at the limit of the allowable temperature fuel elements during reactor operation. ensuring that the implementation of the test by using this device, the temperature is still within safety limits. The calculation is done by making a model sipping test tubes containing a fuel element surrounded by 9 fuel elements. according to the position sipping test tubes in the reactor core. by using Gambit. Dimensional model adapted to the dimensions of the tube and the fuel element in the reactor core of Bandung TRIGA 2000 reactor. Sipping test Operation for each fuel element performed for 30 minutes at 300 kW power. Calculations were performed using CFD software and as input adjusted parameters of TRIGA 2000 reactor. Simulations carried out on the operation of the 30, 60, 90, 120, 150, 180 and 210 minutes. The calculation result shows that the temperature of the fuel in tubes sipping test of 236.06 °C, while the temperature of the wall is 87.58 °C. The maximum temperature in the fuel center of TRIGA 2000 reactor in normal operation is 650 °C. and the boiling is not allowed in the reactor. So it can be concluded that the operation of the sipping test device are is very safe because the fuel center temperature is below the temperature limits the allowable fuel under normal operating conditions as well as the fuel element wall temperature is below the boiling temperature of water. (author)

  2. Experience from and research activities at the Otaniemi TRIGA reactor

    International Nuclear Information System (INIS)

    Bars, Bruno

    1976-01-01

    Experience from the Finnish TRIGA Reactor is reported, small changes and improvements in the control console of the Fir-1 reactor have been made. A minicomputer based data collecting system is planned and installed. It will be used for collecting data from operation and radiation monitors including the new isotope laboratory, and also simultaneously smaller experiments such as control rod calibration. A minicomputer is used for on-line reactor noise studies. The automatic uranium analyzer has a maximum sensitivity of 0.03 μg U 235 and 1.2 Th 232 . The system is now used at a sampling rate of about one sample per minute. (author)

  3. Studies on decommissioning of TRIGA reactors and site restoration technologies in the Republic of Korea

    International Nuclear Information System (INIS)

    Oh, Won-Zin; Kim, Gye-Nam; Won, Hui-Jun

    2002-01-01

    Research and development on research reactor decommissioning and environmental restoration has been carried out at KAERI since 1997 to prepare for the decommissioning of KAERI's two TRIGA-type research reactors, which had been shut down since 1995. A 3-D graphic model of the TRIGA research reactor was built using IGRIP. The dismantling process was simulated in the graphic environment to verify the feasibility of individual operations before the execution of the remote dismantling process. An under-water wall-climbing robot, moving by propeller injection, and identifying its coordinates by using a laser sensor, was developed and tested in the TRIGA reactor pool by measuring a radioactive contamination map of the reactor surface. Using MODFLOW and TRIGA site geological data, a computer simulation of the underground migration of residual radionuclides, after the TRIGA reactor decommissioning, was carried out. It was found that the underground migration rate was very slow such that, when radionuclide decay and dilution are considered, the residual radionuclides will not have a significant environmental impact. The soil decontamination R and D, using soil washing, solvent flushing and electro-decontamination technologies, was carried out to determine the best method for decontaminating the soil waste accumulated in KAERI. The decontamination results indicated that, using the soil washing method, more than 80% of the soil wastes could be decontaminated well enough to discharge them to the environment. It was also determined that the control of solution pH and temperature in the soil washing process is important for the reduction of decontamination waste. Further decontamination, using an electro-kinetic decontamination method, was considered necessary for the residual soil waste, which consisted mainly of fine soil particles. (author)

  4. Reactor instrumentation renewal of the TRIGA reactor Vienna, Austria

    International Nuclear Information System (INIS)

    Boeck, H.; Weiss, H.; Hood, W.E.; Hyde, W.K.

    1992-01-01

    The TRIGA Mark-II reactor at the Atominstitut in Vienna, Austria is replacing its twenty-four year old instrumentation system with a microprocessor based control system supplied by General Atomics. Ageing components, new governmental safety requirements and a need for state of the art instrumentation for training students has spurred the demand for new reactor instrumentation. In Austria a government appointed expert is assigned the responsibility of reviewing the proposed installation and verifying all safety aspects. After a positive review, final assembly and checkout of the instrumentation system may commence. The instrumentation system consists of three basic modules: the control system console, the data acquisition console and the NH-1000 wide range channel. Digital communications greatly reduce interwiring requirements. Hardwired safety channels are independent of computer control, thus, the instrumentation system in no way relies on any computer intervention for safety function. In addition, both the CSC and DAC computers are continuously monitored for proper operation via watchdog circuits which are capable of shutting down the reactor in the event of computer malfunction. Safety channels include two interlocked NMP-1000 multi-range linear channels for steady state mode, an NPP-1000 linear safety channel for pulse mode and a set of three independent fuel temperature monitoring channels. The microprocessor controlled wide range NM- 1000 digital neutron monitor (fission chamber based) functions as a startup/operational channel, and provides all power level related Interlocks. The Atominstitut TRIGA reactor is configured for four modes of operation: manual mode, automatic mode (servo control), pulsing mode and square wave mode. Control of the standard control rods is via stepping motor control rod drives, which offers the operator the choice of which control rods are operated by the servo system in automatic and square wave model. (author)

  5. European TRIGA owners' conference. Papers and abstracts

    International Nuclear Information System (INIS)

    1970-01-01

    The conference covers the following topics, concerning TRIGA reactors: Experience in the Operation and Maintenance and utilization of TRIGA reactors; reactor upgrading; irradiation facilities; fuel management; air-concentration measurements; nuclear tests; use of TRIGA in nuclear medicine and biology; reactor design, fuel and performance; failures and other research activities

  6. Corrosion problem in the CRENK Triga Mark II research reactor

    International Nuclear Information System (INIS)

    Kalenga, M.

    1990-01-01

    In August 1987, a routine underwater optical inspection of the aluminum tank housing the core of the CRENK Triga Mark II reactor, carried out to update safety condition of the reactor, revealed pitting corrosion attacks on the 8 mm thick aluminum tank bottom. The paper discuss the work carried out by the reactor staff to dismantle the reactor in order to allow a more precise investigation of the corrosion problem, to repair the aluminum tank bottom, and to enhance the reactor overall safety condition

  7. Specimen rotation system of the WSU TRIGA-fueled reactor

    International Nuclear Information System (INIS)

    Lovas, Thomas A.

    1976-01-01

    The specimen rotation system presently in use at the WSU reactor has been designed to provide maximum utilization of the irradiation capabilities achieved through use of TRIGA-type fuel. This paper describes the system with particular emphasis on characteristics which are advantageous to experimenters. (author)

  8. Twelfth European TRIGA users conference. Papers and abstracts

    International Nuclear Information System (INIS)

    2008-01-01

    The Twelfth European TRIGA Users Conference was held in Pitesti, Romania, on September 28 - October 1, 1992, under the sponsorship of the Institute for Nuclear Research. The papers which follow in this document are presented in the same order as listed in the Conference Program. All papers which were received for publication (44) have been included. Those papers which were presented but not received for publication are presented in abstract form (3). The European TRIGA9 Owners' Group was fortunate to be hosted by the owners and users of the world's largest TRIGA reactor - the 14-MW Romanian research and test reactor. For too many years it has been impossible to enjoy open interactions with the Romanian researchers. By hosting the 1992 European TRIGA Users' Conference in Romania, the Romanians accomplished a breakthrough in the exchange of TRIGA reactor technology. It was very interesting for the Conference attendees from the West to learn about the large scope of excellent work conducted in Romania, especially at the Institute of Nuclear Research in Pitesti. Similarly, it was fortunate that a large attendance of Romanian researchers from many institutes, universities, and government agencies could attend the Conference and interact with their counterparts from outside Romania. The proceedings of the conference were structured onto the following 6 subject matters: - Opening Session and Introduction; - Session I, Operating and Maintenance Experience (10 papers); - Session II, Reactor Physics And Fuel Utilization (11 papers); - Session III, Instrumentation and Control (5 papers); - Session IV, Irradiation Facilities, Experimental Accessories (8 papers); - Session V, Applications, New Development of TRIGA Concept (6 papers). The document is completed with the abstracts of 3 contributions. A number of 19 experts from Austria, Germany, Italy, United States, Turkey, Morocco, England, Slovenia and Albania, that use TRIGA reactors, and Romania attended the conference. The

  9. Neutronic performance of a 14 MW TRIGA reactor: LEU vs HEU fuel

    International Nuclear Information System (INIS)

    Bretscher, M.M.; Snelgrove, J.L.; Cornella, R.J.

    1983-01-01

    A primary objective of the US Reduced Enrichment Research and Test Reactor (RERTR) Program is to develop means for replacing, wherever possible, currently used highly-enriched uranium (HEU) fuel ( 235 U enrichment > 90%) with low-enriched uranium (LEU) fuel ( 235 U enrichment < 20%) without significantly degrading the performance of research and test reactors. The General Atomic Company has developed a low-enriched but high uranium content Er-U-ZrH/sub 1.6/ fuel to enable the conversion of TRIGA reactors (and others) from HEU to LEU. One possible application is to the water-moderated 14 MW TRIGA Steady State Reactor (SSR) at the Romanian Institute for Nuclear Power Reactors. The work reported here was undertaken for the purpose of comparing the neutronic performance of the SSR for HEU fuel with that for LEU fuel. In order to make these relative comparisons as valid as possible, identical methods and models were used for the neutronic calculations

  10. Feasibility study of the university of Utah TRIGA reactor power upgrade - Part I: Neutronics-based study in respect to control rod system requirements and design

    Directory of Open Access Journals (Sweden)

    Ćutić Avdo

    2013-01-01

    Full Text Available We present a summary of extensive studies in determining the highest achievable power level of the current University of Utah TRIGA core configuration in respect to control rod requirements. Although the currently licensed University of Utah TRIGA power of 100 kW provides an excellent setting for a wide range of experiments, we investigate the possibility of increasing the power with the existing fuel elements and core structure. Thus, we have developed numerical models in combination with experimental procedures so as to assess the potential maximum University of Utah TRIGA power with the currently available control rod system and have created feasibility studies for assessing new core configurations that could provide higher core power levels. For the maximum determined power of a new University of Utah TRIGA core arrangement, a new control rod system was proposed.

  11. Fluid Flow Characteristic Simulation of the Original TRIGA 2000 Reactor Design Using Computational Fluid Dynamics Code

    International Nuclear Information System (INIS)

    Fiantini, Rosalina; Umar, Efrizon

    2010-01-01

    Common energy crisis has modified the national energy policy which is in the beginning based on natural resources becoming based on technology, therefore the capability to understanding the basic and applied science is needed to supporting those policies. National energy policy which aims at new energy exploitation, such as nuclear energy is including many efforts to increase the safety reactor core condition and optimize the related aspects and the ability to build new research reactor with properly design. The previous analysis of the modification TRIGA 2000 Reactor design indicates that forced convection of the primary coolant system put on an effect to the flow characteristic in the reactor core, but relatively insignificant effect to the flow velocity in the reactor core. In this analysis, the lid of reactor core is closed. However the forced convection effect is still presented. This analysis shows the fluid flow velocity vector in the model area without exception. Result of this analysis indicates that in the original design of TRIGA 2000 reactor, there is still forced convection effects occur but less than in the modified TRIGA 2000 design.

  12. Using TRIGA Mark II research reactor for irradiation with thermal neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Kolšek, Aljaž, E-mail: aljaz.kolsek@gmail.com; Radulović, Vladimir, E-mail: vladimir.radulovic@ijs.si; Trkov, Andrej, E-mail: andrej.trkov@ijs.si; Snoj, Luka, E-mail: luka.snoj@ijs.si

    2015-03-15

    Highlights: • Monte Carlo N-Particle Transport Code was used to design and perform calculations. • Characterization of the TRIGA Mark II ex-core irradiation facilities was performed. • The irradiation device was designed in the TRIGA irradiation channel. • The use of the device improves the fraction of thermal neutron flux by 390%. - Abstract: Recently a series of test irradiations was performed at the JSI TRIGA Mark II reactor for the Fission Track-Thermoionization Mass Spectrometry (FT-TIMS) method, which requires a well thermalized neutron spectrum for sample irradiation. For this purpose the Monte Carlo N-Particle Transport Code (MCNP5) was used to computationally support the design of an irradiation device inside the TRIGA model and to support the actual measurements by calculating the neutron fluxes inside the major ex-core irradiation facilities. The irradiation device, filled with heavy water, was designed and optimized inside the Thermal Column and the additional moderation was placed inside the Elevated Piercing Port. The use of the device improves the ratio of thermal neutron flux to the sum of epithermal and fast neutron flux inside the Thermal Column Port by 390% and achieves the desired thermal neutron fluence of 10{sup 15} neutrons/cm{sup 2} in irradiation time of 20 h.

  13. Development of the Fuel Element Database of PUSPATI TRIGA Reactor

    International Nuclear Information System (INIS)

    Nurhayati Ramli; Naim Syauqi Hamzah; Nurfazila Husain; Yahya Ismail; Mat Zin Mat Husin; Mohd Fairus Abd Farid

    2015-01-01

    Since June 28th, 1982, the PUSPATI TRIGA Reactor (RTP) operates safely with an accumulated energy release of about 17,200 MWhr, which corresponds to about 882 g of uranium burn-up. The reactor core has been reconfigured 15th times. Presently, there are 111 TRIGA fuel elements in the core, which 66 of the fuel elements are from the initial criticality while the rest of the fuel elements have been added to compensate the uranium consumption. As 59 % of the fuel elements are older than 30 years old, it is necessary to put the history of every fuel element in a database for easy access of the fuel element movement, inspection results history and integrity status. This paper intends to describe how the fuel element database is developed and related formulae used in determining the RTP fuel element elongation. (author)

  14. Neutron flux measurement and thermal power calibration of the IAN-R1 TRIGA reactor

    Energy Technology Data Exchange (ETDEWEB)

    Sarta Fuentes, Jose A.; Castiblanco Bohorquez, Luis A

    2008-10-29

    The IAN-R1 TRIGA reactor in Colombia was initially fueled with MTR-HEU enriched to 93% U-235, operated since 1965 at 10 kW, and was upgraded to 30 kW in 1980. General Atomics achieved in 1997 the conversion of HEU fuel to LEU fuel TRIGA type, and upgraded the reactor power to 100 kW. Since the IAN-R1 TRIGA reactor was in an extended shutdown during seven years, it was necessary to repeat some results of the commissioning test conducted in 1997. The thermal power calibration was carried out using the calorimetric method. The reactor was operated approximately at 20 kW during 3.5 hours, with manual power corrections since the automatic control system failed and with the forced refrigeration off. During the calorimetric experiment, the pool temperature was measured with a RTD which is installed near to the core. The dates were collected in intervals of 30 minutes. For establishing thermal power reactor, the water temperature versus the running were registered. For a calculated tank volume of 16 m{sup 3}, the tank constant calculated for the IAN-R1 TRIGA reactor is 0.0539 C/kW-hr. The reactor power determined was 19 kW. The core configuration is a rectangular grid plate that holds a combination of 4-rod and 3-rod clusters. The core contains 50 fuel rods with LEU fuel TRIGA (UZr H1.6) type enriched to 19.7%. The radial reflector consists of twenty graphite elements six of which are used for isotope production. The top an bottom reflectors are the cylindrical graphite end reflectors which are installed above and below of the active fuel section in each fuel rod. The spatial dependence of thermal neutron flux was measured axially in the 3-rod clusters 4C, 3D, 5E and in the 4F graphite element. The spatial distribution of the thermal neutron was determined using a self-powered detector and the absolute value of thermal neutron flux was determined by a gold activation detector. The (n, b- ) reaction is applied to determine the relative spatial distribution of thermal

  15. Cross-disciplinary research programs at the Cornell TRIGA reactor

    International Nuclear Information System (INIS)

    Clark, D.D.

    1995-01-01

    This paper describes cross-disciplinary research efforts at the Cornell TRIGA reactor. A new graduate laboratory course for nonspecialists was developed which brought in graduate students from many fields, and a weekly or bimonthly nuclear methods seminars are being held to describe research methods, sample preparation, irradiation, etc

  16. Stack Monitoring System At PUSPATI TRIGA Reactor

    International Nuclear Information System (INIS)

    Zamrul Faizad Omar; Mohd Sabri Minhat; Zareen Khan Abdul Jalil Khan; Ridzuan Abdul Mutalib; Khairulezwan Abdul Manan; Nurfarhana Ayuni Joha; Izhar Abu Hussin

    2014-01-01

    This paper describes the current Stack Monitoring System at PUSPATI TRIGA Reactor (RTP) building. A stack monitoring system is a continuous air monitor placed at the reactor top for monitoring the presence of radioactive gaseous in the effluent air from the RTP building. The system consists of four detectors that provide the reading for background, particulate, Iodine and Noble gas. There is a plan to replace the current system due to frequent fault of the system, thus thorough understanding of the current system is required. Overview of the whole system will be explained in this paper. Some current results would be displayed and moving forward brief plan would be mentioned. (author)

  17. Safety Management at PUSPATI TRIGA Reactor (RTP)

    International Nuclear Information System (INIS)

    Ligam, A.S.; Zarina Masood; Ahmad Nabil Abdul Rahim

    2011-01-01

    Adequate safety measures and precautions, which follow relevant safety standards and procedures, should be in place so that personnel safety is assured. Nevertheless, the public, visitor, contractor or anyone who wishes to enter or be in the reactor building should be well informed with the safety measures applied. Furthermore, these same elements of safety are also applied to other irradiation facilities within the premises of Nuclear Malaysia. This paper will describes and explains current safety management system being enforced especially in the TRIGA PUSPATI Reactor (RTP) namely radiation monitoring system, safety equipment, safe work instruction, and interconnected internal and external health, safety and security related departments. (author)

  18. University Reactor Instrumentation Grant. Final report 08/06/1998 - 08/13/1999

    International Nuclear Information System (INIS)

    Bajorek, S. M.

    2000-01-01

    A noble gas air monitoring system was purchased through the University Reactor Instrumentation Grant Program. This monitor was installed in the Kansas State TRIGA reactor bay at a location near the top surface of the reactor pool according to recommendation by the supplier. This system is now functional and has been incorporated into the facility license

  19. Evaluation of thermal-hydraulic parameter uncertainties in a TRIGA research reactor

    International Nuclear Information System (INIS)

    Mesquita, Amir Z.; Costa, Antonio C.L.; Ladeira, Luiz C.D.; Rezende, Hugo C.; Palma, Daniel A.P.

    2015-01-01

    Experimental studies had been performed in the TRIGA Research Nuclear Reactor of CDTN/CNEN to find out the its thermal hydraulic parameters. Fuel to coolant heat transfer patterns must be evaluated as function of the reactor power in order to assess the thermal hydraulic performance of the core. The heat generated by nuclear fission in the reactor core is transferred from fuel elements to the cooling system through the fuel-cladding (gap) and the cladding to coolant interfaces. As the reactor core power increases the heat transfer regime from the fuel cladding to the coolant changes from single-phase natural convection to subcooled nucleate boiling. This paper presents the uncertainty analysis in the results of the thermal hydraulics experiments performed. The methodology used to evaluate the propagation of uncertainty in the results was done based on the pioneering article of Kline and McClintock, with the propagation of uncertainties based on the specification of uncertainties in various primary measurements. The uncertainty analysis on thermal hydraulics parameters of the CDTN TRIGA fuel element is determined, basically, by the uncertainty of the reactor's thermal power. (author)

  20. Design and implementation of the control system for the new console of TRIGA-3-Salazar Reactor

    International Nuclear Information System (INIS)

    Gonzalez M, J.L.

    1994-01-01

    TRIGA-3-Salazar Reactor was set in operation in 1968 and the aging of its components has cause the increasing in the maintenance. In the presence of this, it becomes necessary to replace the reactor console using new technologies, considering the incorporation of a personal computer. The aim of this work is the design and construction of the equipment interfaces as well as the digital computer program for the automation and control of the TRIGA-3-Salazar Reactor by means of a personal computer. (Author)

  1. Measuring temperature coefficient of TRIGA MARK I reactor by noise analysis

    International Nuclear Information System (INIS)

    Soares, P.A.

    1975-01-01

    The transfer function of TRIGA MARK I Reactor is measured at power zero (5w) and power 118Kw, in the frequency range of 0.02 to 0.5 rd/s. The method of intercorrelation between a pseudostochasticbinary signal is used. A simple dynamic model of the reactor is developed and the coefficient of temperature is estimated [pt

  2. Criticality calculation in TRIGA MARK II PUSPATI Reactor using Monte Carlo code

    International Nuclear Information System (INIS)

    Rafhayudi Jamro; Redzuwan Yahaya; Abdul Aziz Mohamed; Eid Abdel-Munem; Megat Harun Al-Rashid; Julia Abdul Karim; Ikki Kurniawan; Hafizal Yazid; Azraf Azman; Shukri Mohd

    2008-01-01

    A Monte Carlo simulation of the Malaysian nuclear reactor has been performed using MCNP Version 5 code. The purpose of the work is the determination of the multiplication factor (k e ff) for the TRIGA Mark II research reactor in Malaysia based on Monte Carlo method. This work has been performed to calculate the value of k e ff for two cases, which are the control rod either fully withdrawn or fully inserted to construct a complete model of the TRIGA Mark II PUSPATI Reactor (RTP). The RTP core was modeled as close as possible to the real core and the results of k e ff from MCNP5 were obtained when the control fuel rods were fully inserted, the k e ff value indicates the RTP reactor was in the subcritical condition with a value of 0.98370±0.00054. When the control fuel rods were fully withdrawn the value of k e ff value indicates the RTP reactor is in the supercritical condition, that is 1.10773±0.00083. (Author)

  3. Decommissioning of the ICI TRIGA Mark I reactor

    International Nuclear Information System (INIS)

    Parry, D.R.; England, M.R.; Ward, A.; Green, D.

    2000-01-01

    This paper considers the fuel removal, transportation and subsequent decommissioning of the ICI TRIGA Mark I Reactor at Billingham, UK. BNFL Waste Management and Decommissioning carried out this work on behalf of ICI. The decommissioning methodology was considered in the four stages to be described, namely Preparatory Works, Reactor Defueling, Intermediate Level Waste Removal and Low Level Waste Removal. This paper describes the principal methodologies involved in the defueling of the reactor and subsequent decommissioning operations, highlighting in particular the design and safety case methodologies used in order to achieve a solution which was completed without incident or accident and resulted in a cumulative radiation dose to personnel of only 1.57 mSv. (author)

  4. Validation of neutron flux redistribution factors in JSI TRIGA reactor due to control rod movements

    International Nuclear Information System (INIS)

    Kaiba, Tanja; Žerovnik, Gašper; Jazbec, Anže; Štancar, Žiga; Barbot, Loïc; Fourmentel, Damien; Snoj, Luka

    2015-01-01

    For efficient utilization of research reactors, such as TRIGA Mark II reactor in Ljubljana, it is important to know neutron flux distribution in the reactor as accurately as possible. The focus of this study is on the neutron flux redistributions due to control rod movements. For analyzing neutron flux redistributions, Monte Carlo calculations of fission rate distributions with the JSI TRIGA reactor model at different control rod configurations have been performed. Sensitivity of the detector response due to control rod movement have been studied. Optimal radial and axial positions of the detector have been determined. Measurements of the axial neutron flux distribution using the CEA manufactured fission chambers have been performed. The experiments at different control rod positions were conducted and compared with the MCNP calculations for a fixed detector axial position. In the future, simultaneous on-line measurements with multiple fission chambers will be performed inside the reactor core for a more accurate on-line power monitoring system. - Highlights: • Neutron flux redistribution due to control rod movement in JSI TRIGA has been studied. • Detector response sensitivity to the control rod position has been minimized. • Optimal radial and axial detector positions have been determined

  5. Environmental Assessment: Relocation and storage of TRIGA reg-sign reactor fuel, Hanford Site, Richland, Washington

    International Nuclear Information System (INIS)

    1995-08-01

    In order to allow the shutdown of the Hanford 308 Building in the 300 Area, it is proposed to relocate fuel assemblies (101 irradiated, three unirradiated) from the Mark I TRIGA Reactor storage pool. The irradiated fuel assemblies would be stored in casks in the Interim Storage Area in the Hanford 400 Area; the three unirradiated ones would be transferred to another TRIGA reactor. The relocation is not expected to change the offsite exposure from all Hanford Site 300 and 400 Area operations

  6. Analysis concerning the perspective of Romania-USA technological cooperation with a view to performing TRIGA reactor project

    International Nuclear Information System (INIS)

    Ciocanescu, M.; Ionescu, M.; Constantin, L.

    1998-01-01

    The co-operation between Romania and the USA in the field of technologic transfer of nuclear research reactor technology began with the steady state 14 MW, TRIGA reactor, installed at INR Pitesti, Romania. It is the first in the range of TRIGA reactors proposed as a materials testing reactor. The first criticality was reached in November 19, 1979 and first operation at 14 MW, level was in February 1980. The paper will present the short history of this co-operation and the perspective for a new co-operation for building a Nuclear Heating Plant using the TRIGA reactor concept for demonstration purpose. The energy crisis is a world-wide problem which affects each country in different ways because the resources and the consumption are unfairly distributed. World-wide research points out that the fossil fuel sources are not to be considered the main energy sources for the long term as they are limited. (author)

  7. Simulation of the TRIGA-ININ reactor using EXT-2, in R-{theta} R{theta} and temperature of 20 Centigrade; Simulacion del reactor TRIGA-ININ utilizando EXT-2, en geometria R-{theta} y una temperatura de 20 Centigrados

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar H, F [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1983-10-15

    The simulation of the TRIGA-ININ reactor, it was beginning considering the more simple case (follower bars equal to fuel elements, cell bar transitory with vacuum, etc.), this it left tuning as the obtained results were observed and it was studied the literature with respect to this reactor, in the following step the followers are considered as standard elements but with 32 grams of U-235 and so forth until reaching to the configuration that is considered definitive. (Author)

  8. Fuel burnup analysis for the Moroccan TRIGA research reactor

    International Nuclear Information System (INIS)

    El Bakkari, B.; El Bardouni, T.; Nacir, B.; El Younoussi, C.; Boulaich, Y.; Boukhal, H.; Zoubair, M.

    2013-01-01

    Highlights: ► A fuel burnup analysis of the 2 MW TRIGA MARK II Moroccan research reactor was established. ► Burnup calculations were done by means of the in-house developed burnup code BUCAL1. ► BUCAL1 uses the MCNP tallies directly in the calculation of the isotopic inventories. ► The reactor life time was found to be 3360 MW h considering full power operating conditions. ► Power factors and fluxes of the in-core irradiation positions are strongly affected by burnup. -- Abstract: The fundamental advantage and main reason to use Monte Carlo methods for burnup calculations is the possibility to generate extremely accurate burnup dependent one group cross-sections and neutron fluxes for arbitrary core and fuel geometries. Yet, a set of values determined for a material at a given position and time remains accurate only in a local region, in which neutron spectrum and flux vary weakly — and only for a limited period of time, during which changes of the local isotopic composition are minor. This paper presents the approach of fuel burnup evaluation used at the Moroccan TRIGA MARK II research reactor. The approach is essentially based upon the utilization of BUCAL1, an in-house developed burnup code. BUCAL1 is a FORTRAN computer code designed to aid in analysis, prediction, and optimization of fuel burnup performance in nuclear reactors. The code was developed to incorporate the neutron absorption reaction tally information generated directly by MCNP5 code in the calculation of fissioned or neutron-transmuted isotopes for multi-fueled regions. The fuel cycle length and changes in several core parameters such as: core excess reactivity, control rods position, fluxes at the irradiation positions, axial and radial power factors and other parameters are estimated. Besides, this study gives valuable insight into the behavior of the reactor and will ensure better utilization and operation of the reactor during its life-time and it will allow the establishment of

  9. Radiological control guide for decommissioning of the TRIGA mark-2, 3

    International Nuclear Information System (INIS)

    Lee, Bong Jae

    2000-08-01

    The purpose of radiological control for TRIGA mark-2, 3 research reactors and facilities at the KAERI Seoul site, which are to be decommissioned, is in minimizing the radiation exposure for workers and in preventing the release of the radioactive materials to the environment. In order to accomplish these goal, the radiological control guide will be prepared during the decommissioning activities. Therefore, it is expected that this technical report can be used in preparing radiological control guide for safety decommissioning of the TRIGA mark-2, 3

  10. ENEA TRIGA RC-1 reactor activities in the fields of nuclear medicine and neutron radiography

    International Nuclear Information System (INIS)

    Chiesa, Gianni; Festinesi, Armando; Palomba, Mario; Rosa, Roberto; Rossi, Gabriela; Sangiovanni, Gino; Santoro, Emilio; Sedda, Antioco Franco; Storelli, Lucio

    2008-01-01

    In the last three years, TRIGA RC-1 plant staff is involved in collaborations with some roman hospitals for the production of particular radioisotopes for the diagnosis and therapy in the field of human cancer. Further, the thermal column of TRIGA reactor has been prepared for neutron radiography and tomography. For another channel, instruments and equipment above neutron radiography and tomography are in preparation phase. This paper includes an overview of the experimental equipment properly developed by TRIGA staff. (authors)

  11. TRIGA reactor to be introduced for therapy. Uudentyyppinen saedehoito aivokasvainten hoitoon

    Energy Technology Data Exchange (ETDEWEB)

    Hiisimaeki, P.; Kallio, M.

    1994-01-01

    The possibility to use the FIR-1 (TRIGA) reactor located in Espoo (in Finland) as a neutron source for the Boron Neutron Capture Therapy (BNCT), a medical treatment method for gliomas in brains, is discussed in the article.

  12. Current development in data acquision and processing system for reactor noise analysis in PUSPATI

    International Nuclear Information System (INIS)

    Mohamad Amin Sharifuldin Salleh.

    1986-11-01

    A data acquisition and processing system for reactor noise analysis is described. It consists of four-channel isolation amplifier, a seven-channel DC amplifier, a four-channel analog to digital converter, analog filters, a microcomputer system and a plotter. This system is being applied to investigate the reactor dynamics of the PUSPATI TRIGA MK II reactor. (author)

  13. Monte Carlo analysis of Musashi TRIGA mark II reactor core

    International Nuclear Information System (INIS)

    Matsumoto, Tetsuo

    1999-01-01

    The analysis of the TRIGA-II core at the Musashi Institute of Technology Research Reactor (Musashi reactor, 100 kW) was performed by the three-dimensional continuous-energy Monte Carlo code (MCNP4A). Effective multiplication factors (k eff ) for the several fuel-loading patterns including the initial core criticality experiment, the fuel element and control rod reactivity worth as well as the neutron flux measurements were used in the validation process of the physical model and neutron cross section data from the ENDF/B-V evaluation. The calculated k eff overestimated the experimental data by about 1.0%Δk/k for both the initial core and the several fuel-loading arrangements. The calculated reactivity worths of control rod and fuel element agree well the measured ones within the uncertainties. The comparison of neutron flux distribution was consistent with the experimental ones which were measured by activation methods at the sample irradiation tubes. All in all, the agreement between the MCNP predictions and the experimentally determined values is good, which indicated that the Monte Carlo model is enough to simulate the Musashi TRIGA-II reactor core. (author)

  14. Data base formation for important components of reactor TRIGA MARK II

    International Nuclear Information System (INIS)

    Jordan, R.; Mavko, B.; Kozuh, M.

    1992-01-01

    The paper represents specific data base formation for reactor TRIGA MARK II in Podgorica. Reactor operation data from year 1985 to 1990 were collected. Two groups of collected data were formed. The first group includes components data and the second group covers data of reactor scrams. Time related and demand related models were used for data evaluation. Parameters were estimated by classical method. Similar data bases are useful everywhere where components unavailabilities may have severe drawback. (author) [sl

  15. Thermal hydraulic analysis of the IPR-R1 TRIGA research reactor using a RELAP5 model

    International Nuclear Information System (INIS)

    Costa, Antonella L.; Reis, Patricia Amelia L.; Pereira, Claubia; Veloso, Maria Auxiliadora F.; Mesquita, Amir Z.; Soares, Humberto V.

    2010-01-01

    The RELAP5 code is widely used for thermal hydraulic studies of commercial nuclear power plants. Current investigations and code adaptations have demonstrated that the RELAP5 code can be also applied for thermal hydraulic analysis of nuclear research reactors with good predictions. Therefore, as a contribution to the assessment of RELAP5/MOD3.3 for research reactors analysis, this work presents steady-state and transient calculation results performed using a RELAP5 model to simulate the IPR-R1 TRIGA research reactor at 50 kilowatts (kW) of power operation. The reactor is located in the Nuclear Technology Development Center (CDTN), Brazil. It is a 250 kW, light water moderated and cooled, graphite-reflected, open pool type research reactor. The development and the assessment of a RELAP5 model for the IPR-R1 TRIGA are presented. Experimental data were considered in the process of the RELAP5 model validation. The RELAP5 results were also compared with calculated data from the STHIRP-1 (Research Reactors Thermal Hydraulic Simulation) code. The results obtained have shown that the RELAP5 model for the IPR-R1 TRIGA reproduces the actual steady-state reactor behavior in good agreement with the available data.

  16. TRIGA Research Reactor Conversion to LEU and Modernization of Safety Related Systems

    Energy Technology Data Exchange (ETDEWEB)

    Sanda, R. M. [Institute for Nuclear Research Piteşti (SCN-Piteşti), Piteşti (Romania)

    2014-08-15

    The USA and IAEA proposed an international programme to reduce the enrichment of uranium in research reactors by converting nuclear fuel containing HEU into fuel containing 20% enriched uranium. The Government of Romania joined the programme and actively supported political, scientific, technical and economic actions that led to the conversion of the active area of the 14 MW TRIGA reactor at the Institute for Nuclear Research in Piteşti in May 2006. This confirmed the continuity of the Romanian Government’s non-proliferation policy and their active support of international cooperation. Conversion of the Piteşti research reactor was made possible by completion of milestones in the Research Agreement for Reactor Conversion, a contract signed with the US Department of Energy and Argonne National Laboratory. This agreement provided scientific and technical support and the possibility of delivery of all HEU TRIGA fuel to the United States. Additionally, about 65% of the fresh LEU fuel needed to start the conversion was delivered in the period 1992–1994. Furthermore, conversion was promoted through IAEA Technical Cooperation project ROM/4/024 project funded primarily by the United States that supported technical and scientific efforts and the delivery of the remaining required LEU nuclear fuel to complete the conversion. Nuclear fuel to complete the conversion was made by the French company CERCA with a tripartite contract among the IAEA, CERCA and Romania. The contract was funded by the US Department of Energy with a voluntary contribution by the Romanian Government. The contract stipulated manufacturing and delivery of LEU fuel by CERCA with compliance measures for quality, delivery schedule and safety requirements set by IAEA standards and Romanian legislation. The project was supported by the ongoing technical cooperation, safeguards, legal and procurement assistance of the IAEA, in particular its Department of Nuclear Safety. For Romanian research, the

  17. Calculation of power density with MCNP in TRIGA reactor

    International Nuclear Information System (INIS)

    Snoj, L.; Ravnik, M.

    2006-01-01

    Modern Monte Carlo codes (e.g. MCNP) allow calculation of power density distribution in 3-D geometry assuming detailed geometry without unit-cell homogenization. To normalize MCNP calculation by the steady-state thermal power of a reactor, one must use appropriate scaling factors. The description of the scaling factors is not adequately described in the MCNP manual and requires detailed knowledge of the code model. As the application of MCNP for power density calculation in TRIGA reactors has not been reported in open literature, the procedure of calculating power density with MCNP and its normalization to the power level of a reactor is described in the paper. (author)

  18. Present status and future prospect of research reactors

    International Nuclear Information System (INIS)

    Takemi, Hirokatsu

    1996-01-01

    The present status of research reactors more than MW class reactor in JAERI and the Kyoto University and the small reactors in the Musashi Institute of Technology, the Rikkyo University, the Tokyo University, the Kinki University and other countries are explained in the paper. The present status of researches are reported by the topics in each field. The future researches of the beam reactor and the irradiation reactor are reviewed. On various kinds of use of research reactor and demands of neutron field of a high order, new type research reactors under investigation are explained. Recently, the reactors are used in many fields such as the basic science: the basic physics, the material science, the nuclear physics, and the nuclear chemistry and the applied science; the earth and environmental science, the biology and the medical science. (S.Y.)

  19. Data base formation for important components of reactor TRIGA MARK II

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, R; Mavko, B; Kozuh, M [Inst. Jozef Stefan, Ljubljana (Slovenia)

    1992-07-01

    The paper represents specific data base formation for reactor TRIGA MARK II in Podgorica. Reactor operation data from year 1985 to 1990 were collected. Two groups of collected data were formed. The first group includes components data and the second group covers data of reactor scrams. Time related and demand related models were used for data evaluation. Parameters were estimated by classical method. Similar data bases are useful everywhere where components unavailabilities may have severe drawback. (author) [Slovenian] V referatu smo prikazali raziskavo, v okviru katere smo za raziskovalni reaktor TRIGA MARK II v Podgorici izoblikovali specificno bazo podatkov. Zbrali smo podatke obratovanja reaktorja od leta 1985 do 1990. Rezultate raziskave dogodkov smo razdelili v dve glavni skupini. V prvo spadajo obratovalni podatki o komponentah, v drugo skupino pa spadajo zagoni oz. zaustavitve reaktorja. Podatke smo ovrednotili z modelom v casovnem prostoru in z modelom na zahtevo. Parametre modelov smo dolocili s klasicno metodo. Opisane baze podatkov so uporabne povsod, kjer so lahko posledice nezanesljivega delovanja sistemov velike. [author].

  20. Safety Evaluation Report related to the renewal of the operating license for the research reactor at Michigan State University (Docket No. 50-294)

    International Nuclear Information System (INIS)

    1984-08-01

    This Safety Evaluation Report for the application filed by the Michigan State University (MSU) for a renewal of operating license number R-114 to continue to operate the TRIGA Mark I research reactor has been prepared by the Office of Nuclear Reactor Regulation of the US Nuclear Regulatory Commission. The facility is owned and operated by the Michigan State University and is located on the campus of Michigan State University in East Lansing, Ingham County, Michigan. The staff concludes that the TRIGA reactor facility can continue to be operated by MSU without endangering the health and safety of the public

  1. The history and perspective of Romania-USA cooperation in the field of technologic transfer of TRIGA reactor concept

    International Nuclear Information System (INIS)

    Ciocaanescu, M.; Ionescu, M.

    1996-01-01

    The cooperation between Romania and the USA in the field of technologic transfer of nuclear research reactor technology began with the steady state 14 MW t TRIGA reactor, installed at INR Pitesti, Romania. It is the first in the range of TRIGA reactors proposed as a materials testing reactor. The first criticality was reached in November 19, 1979 and first operation at 14 MW t level was in February 1980. The paper will present the short history of this cooperation and the perspective for a new cooperation for building a Nuclear Heating Plant using the TRIGA reactor concept for demonstration purpose. The energy crisis is a world-wide problem which affects each country in different ways because the resources and the consumption are unfairly distributed. World-wide research points out that the fossil fuel sources are not to be considered the main energy sources for the long term as they are limited

  2. Conceptual Design of a Clinical BNCT Beam in an Adjacent Dry Cell of the Jozef Stefan Institute TRIGA Reactor

    International Nuclear Information System (INIS)

    Maucec, Marko

    2000-01-01

    The MCNP4B Monte Carlo transport code is used in a feasibility study of the epithermal neutron boron neutron capture therapy facility in the thermalizing column of the 250-kW TRIGA Mark II reactor at the Jozef Stefan Institute (JSI). To boost the epithermal neutron flux at the reference irradiation point, the efficiency of a fission plate with almost 1.5 kg of 20% enriched uranium and 2.3 kW of thermal power is investigated. With the same purpose in mind, the TRIGA reactor core setup is optimized, and standard fresh fuel elements are concentrated partly in the outermost ring of the core. Further, a detailed parametric study of the materials and dimensions for all the relevant parts of the irradiation facility is carried out. Some of the standard epithermal neutron filter/moderator materials, as well as 'pressed-only' low-density Al 2 O 3 and AlF 3 , are considered. The proposed version of the BNCT facility, with PbF 2 as the epithermal neutron filter/moderator, provides an epithermal neutron flux of ∼1.1 x 10 9 n/cm 2 .s, thus enabling patient irradiation times of nfast /φ epi -13 Gy.cm 2 /n and [overdot]D γ /φ epi -13 Gy.cm 2 /n), the in-air performances of the proposed beam are comparable to all existing epithermal BNCT facilities. The design presents an equally efficient alternative to the BNCT beams in TRIGA reactor thermal columns that are more commonly applied. The cavity of the dry cell, a former JSI TRIGA reactor spent-fuel storage facility, adjacent to the thermalizing column, could rather easily be rearranged into a suitable patient treatment room, which would substantially decrease the overall developmental costs

  3. Transition from HEU to LEU fuel in Romania's 14-MW TRIGA reactor

    International Nuclear Information System (INIS)

    Bretscher, M.M.; Snelgrove, J.L.

    1995-01-01

    The 14-MW TRIGA steady state reactor (SSR) located in Pitesti, Romania, first went critical in the fall of 1979. Initially, the core configuration for full power operation used 29 fuel clusters each containing a 5 x 5 square array of HEU U (10 wt% - ZrH - Er 2.8 wt%) fuel-moderator rods (1.295 cm o.d.) clad in Incoloy. With a total inventory of 35 HEU fuel clusters, burnup, considerations required a gradual expansion of the core from 29 to 32 and finally to 35 clusters before the reactor was shut down because of insufficient excess reactivity. At this time each of the original 29 fuel clusters had an average 235 U burnup in the range from 50 to 62%. Because of the U.S. policy regarding the export of highly enriched uranium, fresh HEU TRIGA replacement fuel is not available. After a number of safety-related measurements, the SSR is expected to resume full power operation in the near future using a mixed core containing five LEU TRIGA clusters of the same geometry as the original fuel but with fuel-moderator rods containing 45 wt% U (19.7% 235 U enrichment) and 1.1 wt% Er. Rods for 14 additional LEU fuel clusters will be fabricated by General Atomics. In support of the SSR mixed core operation numerous neutronic calculations have been performed. This paper presents some of the results of those calculations. (author)

  4. An analytical approach to the positive reactivity void coefficient of TRIGA Mark-II reactor

    International Nuclear Information System (INIS)

    Edgue, Erdinc; Yarman, Tolga

    1988-01-01

    Previous calculations of reactivity void coefficient of I.T.U. TRIGA Mark-II Reactor was done by the second author et al. The theoretical predictions were afterwards, checked in this reactor experimentally. In this work an analytical approach is developed to evaluate rather quickly the reactivity void coefficient of I.T.U. TRIGA Mark-II, versus the size of the void inserted into the reactor. It is thus assumed that the reactor is a cylindrical, bare nuclear system. Next a belt of water of 2πrΔrH is introduced axially at a distance r from the center line of the system. r here, is the thickness of the belt, and H is the height of the reactor. The void is described by decreasing the water density in the belt region. A two group diffusion theory is adopted to determine the criticality of our configuration. The space dependency of the group fluxes are, thereby, assumed to be J 0 (2.405 r / R) cos (π Z / H), the same as that associated with the original bare reactor uniformly loaded prior to the change. A perturbation type of approach, thence, furnishes the effect of introducing a void in the belt region. The reactivity void coefficient can, rather surprisingly, be indeed positive. To our knowledge, this fact had not been established, by the supplier. The agreement of our predictions with the experimental results is good. (author)

  5. Fuel element burnup determination in HEU-LEU mixed TRIGA research reactor core

    International Nuclear Information System (INIS)

    Zagar, Tomaz; Ravnik, Matjaz

    2000-01-01

    This paper presents the results of a burnup calculations and burnup measurements for TRIGA FLIP HEU fuel elements and standard TRIGA LEU fuel elements used simultaneously in small TRIGA Mark II research reactor in Ljubljana, Slovenija. The fuel element burnup for approximately 15 years of operation was calculated with two different in house computer codes TRIGAP and TRIGLAV (both codes are available at OECD NEA Data Bank). The calculation is performed in one-dimensional radial geometry in TRIGAP and in two-dimensional (r,φ) geometry in TRIGLAV. Inter-comparison of results shows important influence of in-core water gaps, irradiation channels and mixed rings on burnup calculation accuracy. Burnup of 5 HEU and 27 LEU fuel elements was also measured with reactivity method. Measured and calculated burnup values are inter-compared for these elements (author)

  6. The research reactor TRIGA Mainz. A neutron source for versatile applications in research and education

    International Nuclear Information System (INIS)

    Eberhardt, K.; Kronenberg, A.

    2000-01-01

    Currently, four research reactors with a thermal power ranging from 0.1 to 23 MW th are in operation in Germany and one new reactor (20 MW th ) is under construction. The TRIGA Mark II reactor at the Institut fuer Kernchemie became first critical on August 3, 1965. It can be operated in the steady state mode with a maximum power of 100 kW th and in the pulse mode with a peak power of 250 MW th . A survey of the research programmes carried out at the TRIGA Mainz is given covering a wide range of applications in basic and applied science in nuclear chemistry, nuclear- and particle physics. Furthermore, the reactor is used for neutron activation analysis and for education and training of students and technical personal. (orig.) [de

  7. Isotopes accumulation in the thermal column of TRIGA reactor

    International Nuclear Information System (INIS)

    Iorgulis, C.; Diaconu, D.; Gugiu, D.; Csaba, R.

    2013-01-01

    The correlation of impurity observed in the virgin graphite and radionuclide content and activities measured in the irradiated graphite needs to know the irradiated history. This is a challenging process if impurity content and irradiation conditions are not accurately known. This is the case of the irradiated graphite in the thermal column of Institute for Nuclear Research Pitesti (INR)14 MW TRIGA reactor. To overcome incomplete impurity content and the unknown position in the column of the measured irradiated graphite available for characterisation and comparison, a set of preliminary simulations were performed. Following Eu 152 /Eu 154 ration they allowed the estimation of an impurity content and irradiation conditions leading to measured activities. Based on these data the radio-isotope accumulation in different positions in the thermal column was predicted. Modelling performed by INR used advanced prediction packages (e.g. WIMS, MCNP ORIGEN-S from Scale 5) to assess the isotopic content of MTR graphite types with irradiation history specific for a TRIGA research reactor. Some certain calculations points from the column were selected in order to model the burnup and isotopes productions using ORIGEN from SCALE code system. (authors)

  8. Fuel transfer cask concept design for reactor TRIGA PUSPATI (RTP)

    International Nuclear Information System (INIS)

    Ahmad Nabil Ab Rahim; Phongsakorn Prak; Tonny Lanyau; Mohd Fazli Zakaria

    2010-01-01

    Reactor Triga PUSPATI (RTP) has been operated since 1982 till now. For such long period, the organization feels the need to upgrade the power from 1 MW to 3 MW which involved changing new fuels. Spent fuels will be stored in a Spent Fuel Pool. The process of transferring spent fuels into Spent Fuels Pool required a fuel transfer cask. This paper discussed the design concept for the fuel transfer cast which is essential equipment for reactor upgrading mission. (author)

  9. Steady-state thermal-hydraulic analysis of the Moroccan TRIGA MARK II reactor by using PARET/ANL and COOLOD-N2 codes

    International Nuclear Information System (INIS)

    Boulaich, Y.; Nacir, B.; El Bardouni, T.; Zoubair, M.; El Bakkari, B.; Merroun, O.; El Younoussi, C.; Htet, A.; Boukhal, H.; Chakir, E.

    2011-01-01

    Research highlights: → The COOLOD/N2 and PARET/ANL codes were used for a steady-state thermal-hydraulic and safety analysis of the 2 MW TRIGA MARK II reactor located at the Nuclear Studies Center of Maamora (CENM), Morocco. → The main objective of this study is to ensure the safety margins of different safety related parameters by steady-state calculations at full power level (2 MW). → The most important conclusion is that all obtained values of DNBR, fuel center and surface temperature, cladding surface temperature and coolant temperature across the hottest channel are largely far to compromise safety of the reactor. - Abstract: The COOLOD/N2 and PARET/ANL codes were used for a steady-state thermal-hydraulic and safety analysis of the 2 MW TRIGA MARK II reactor located at the Nuclear Studies Center of Maamora (CENM), Morocco. In order to validate our PARET/ANL and COOLOD-N2 models, the fuel center temperature as function of core power was calculated and compared with the corresponding experimental values. The comparison indicates that the calculated values are in satisfactory agreement with the measurement. The main objective of this study is to ensure the safety margins of different safety related parameters by steady-state calculations at full power level (2 MW). Therefore, we have calculated the departure from nucleate boiling ratio (DNBR), fuel center and surface temperature, cladding surface temperature and coolant temperature profiles across the hottest channel. The most important conclusion is that all obtained values are largely far to compromise safety of the reactor.

  10. Safety Evaluation Report related to the construction permit and operating license for the research reactor at the University of Texas (Docket No. 50-602)

    International Nuclear Information System (INIS)

    1985-05-01

    This Safety Evaluation Report for the application filed by the University of Texas for a construction permit and operating license to construct and operate a TRIGA research reactor has been prepared by the Office of Nuclear Reactor Regulation of the US Nuclear Regulatory Commission. The facility is owned and operated by the University of Texas and is located at the university's Balcones Research Center, about 7 miles (11.6 km) north of the main campus in Austin, Texas. The staff concludes that the TRIGA reactor facility can be constructed and operated by the University of Texas without endangering the health and safety of the public

  11. Applicable regulations and development of surveillance experiments of criticality approach in the TRIGA III Mark reactor; Normativa aplicable y desarrollo de experimentos de vigilancia de aproximacion a criticidad en el reactor Triga Mark III

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez M, J L; Aguilar H, F; Rivero G, T; Sainz M, E [Instituto nacional de Investigaciones Nucleares, Departamento de Automatizacion, A.P. 18-1027, Col. Escandon, 11801 Mexico D.F. (Mexico)

    2000-07-01

    In the procedure elaborated to repair the vessel of TRIGA III Mark reactor is required to move toward two tanks of temporal storage the fuel elements which are in operation and the spent fuel elements which are in decay inside the reactor pool. The National Commission of Nuclear Safety and Safeguards (CNSNS) has requested as protection measure that it is carried out a surveillance of the criticality approach of the temporal storages. This work determines the main regulation aspects that entails an experiment of criticality approach, moreover, informing about the results obtained in the developing of this experiments. The regulation aspects are not exclusives for this work in the TRIGA Mark III reactor but they also apply toward any assembling of fissile material. (Author)

  12. Large Object Irradiation Facility In The Tangential Channel Of The JSI TRIGA Reactor

    CERN Document Server

    Radulovic, Vladimir; Kaiba, Tanja; Kavsek, Darko; Cindro, Vladimir; Mikuz, Marko; Snoj, Luka

    2017-01-01

    This paper presents the design and installation of a new irradiation device in the Tangential Channel of the JSI TRIGA reactor in Ljubljana, Slovenia. The purpose of the device is to enable on-line irradiation testing of electronic components considerably larger in size (of lateral dimensions of at least 12 cm) than currently possible in the irradiation channels located in the reactor core, in a relatively high neutron flux (exceeding 10^12 n cm^-2 s^-1) and to provide adequate neutron and gamma radiation shielding.

  13. TRIGA low enrichment fuel

    International Nuclear Information System (INIS)

    Gietzen, A.

    1993-01-01

    Sixty TRIGA reactors have been sold and the earliest of these are now passing twenty years of operation. All of these reactors use the uranium zirconium hydride fuel (UZrH) which provides certain unique advantages arising out of its large prompt negative temperature coefficient, very low fission product release, and high temperature capability. Eleven of these Sixty reactors are conversions from plate fuel to TRIGA fuel which were made as a result of these advantages. With only a few exceptions, TRIGA reactors have always used low-enriched uranium (LEU) fuel with an enrichment of 19.9%. The exceptions have either been converted from the standard low-enriched fuel to the 70% enriched FLIP fuel in order to achieve extended lifetime, or are higher powered reactors which were designed for long life using 93%-enriched uranium during the time when the use and export of highly enriched uranium (HEU) was not restricted. The advent of international policies focusing attention on nonproliferation and safeguards made the HEU fuels obsolete. General Atomic immediately undertook a development effort (nearly two years ago) in order to be in a position to comply with these policies for all future export sales and also to provide a low-enriched alternative to fully enriched plate-type fuels. This important work was subsequently partially supported by the U.S. Department of Energy. The laboratory and production tests have shown that higher uranium densities can be achieved to compensate for reducing the enrichment to 20%, and that the fuels maintain the characteristics of the very thoroughly proven standard TRIGA fuels. In May of 1978, General Atomic announced that these fuels were available for TRIGA reactors and for plate-type reactors with power levels up to 15 MW with General Atomic's standard commercial warranty

  14. TRIGA low enrichment fuel

    International Nuclear Information System (INIS)

    Gietzen, A.

    1993-01-01

    Sixty TRIGA reactors have been sold and the earliest of these are now passing twenty years of operation. All of these reactors use the uranium-zirconium hydride fuel (UZrH) which provides certain unique advantages arising out of its large prompt negative temperature coefficient, very low fission product release, and high temperature capability. Eleven of these Sixty reactors are conversions from plate fuel to TRIGA fuel which were made as a result of these advantages. With only a few exceptions, TRIGA reactors have always used low-enriched-uranium (LEU) fuel with an enrichment of 19.9%. The exceptions have either been converted from the standard low-enriched fuel to the 70% enriched FLIP fuel in order to achieve extended lifetime, or are higher powered reactors which were designed for long life using 93%-enriched uranium during the time when the use and export of highly enriched uranium (HEU) was not restricted. The advent of international policies focusing attention on nonproliferation and safeguards made the HEU fuels obsolete. General Atomic immediately undertook a development effort (nearly two years ago) in order to be in a position to comply with these policies for all future export sales and also to provide a low-enriched alternative to fully enriched plate-type fuels. This important work was subsequently partially supported by the U.S. Department of Energy. The laboratory and production tests have shown that higher uranium densities can be achieved to compensate for reducing the enrichment to 20%, and that the fuels maintain the characteristics of the very thoroughly proven standard TRIGA fuels. In May of 1978, General Atomic announced that these fuels were available for TRIGA reactors and for plate-type reactors with power levels up to 15 MW with GA's standard commercial warranty

  15. Feasibility study of the university of Utah TRIGA reactor power upgrade - part II: Thermohydraulics and heat transfer study in respect to cooling system requirements and design

    Directory of Open Access Journals (Sweden)

    Babitz Philip

    2013-01-01

    Full Text Available The thermodynamic conditions of the University of Utah's TRIGA Reactor were simulated using SolidWorks Flow Simulation, Ansys, Fluent and PARET-ANL. The models are developed for the reactor's currently maximum operating power of 90 kW, and a few higher power levels to analyze thermohydraulics and heat transfer aspects in determining a design basis for higher power including the cost estimate. It was found that the natural convection current becomes much more pronounced at higher power levels with vortex shedding also occurring. A departure from nucleate boiling analysis showed that while nucleate boiling begins near 210 kW it remains in this state and does not approach the critical heat flux at powers up to 500 kW. Based on these studies, two upgrades are proposed for extended operation and possibly higher reactor power level. Together with the findings from Part I studies, we conclude that increase of the reactor power is highly feasible yet dependable on its purpose and associated investments.

  16. Neutron Field Characterization of Irradiation Locations Applied to the Slovenian TRIGA Reactor

    International Nuclear Information System (INIS)

    Barbot, Loic; Domergue, Christophe; Breaud, Stephane; Destouches, Christophe; Villard, Jean-Francois; Snoj, Luka; Stancar, Ziga; Radulovic, Vladimir; Trkov, Andrej

    2013-06-01

    This work deals with several neutron flux measurement instruments and particle transport calculations combined in a method to assess the neutron field in experimental locations in nuclear reactor core or reflector. First test of this method in the TRIGA Mark II of Slovenia led to the assessment of three energy groups neutron fluxes in central irradiation locations within reactor core. (authors)

  17. Return of TRIGA fuel from the Medical University of Hanover (MHH) to the United States

    International Nuclear Information System (INIS)

    Hampel, Gabriele; Klaus, Uwe; Schmidt, Thomas

    1999-01-01

    The Medical University of Hanover (MHH) returned its TRIGA fuel to the United States in the summer of 1999. This paper deals with the procedure for handling the fuel elements within and outside the reactor facility. It describes the dry loading technology, taking into account the special conditions relevant to the MHH. It also includes the time scale for both the various steps of the procedure and the entire process, as well as the main results of the radiological surveys. (author)

  18. 10. European TRIGA users conference. Papers and abstracts

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1988-07-01

    The Tenth European TRIGA Users Conference was held in Vienna, September 14-16, 1988 under the sponsorship of the Atominstitut. The main areas of discussions were: Reactor operation and maintenance experiences; New developments and improvements of TRIGA components and systems, including instrumentation; Fuel and fuel management; Safety aspects, licensing and radiation protection; Experiments with TRIGA reactors; Radiochemistry, radioisotope production and NAA; and Reactor physics.

  19. 10. European TRIGA users conference. Papers and abstracts

    International Nuclear Information System (INIS)

    1988-01-01

    The Tenth European TRIGA Users Conference was held in Vienna, September 14-16, 1988 under the sponsorship of the Atominstitut. The main areas of discussions were: Reactor operation and maintenance experiences; New developments and improvements of TRIGA components and systems, including instrumentation; Fuel and fuel management; Safety aspects, licensing and radiation protection; Experiments with TRIGA reactors; Radiochemistry, radioisotope production and NAA; and Reactor physics

  20. Seven years of operation of the U. S. geological survey TRIGA reactor

    International Nuclear Information System (INIS)

    Kraker, Pat

    1976-01-01

    February 1976 marks 7 years of operation of the U. S. Geological Survey TRIGA Reactor (GSTR) facility. In these 7 years we have generated more than 5800 MWH's of thermal energy and irradiated more than 47,000 samples for experimenters from the Survey, universities, and other Governmental agencies. Several mechanical and electrical components have required attention. Changes to the technical specifications have included one minor wording change involving the evacuation alarm, a reevaluation of the measurement of argon-41 concentrations, a revision concerning transient-rod maintenance, and a reduction in the frequency of fuel-element measurements. To improve physical security we have increased building security, installed an intrusion alarm, and, most recently, expanded the boundaries of the facility within the building to provide better control access. There also have been major changes to our operating procedures and the initiation of a reactor-operator requalification program. (author)

  1. Sipping test update device for fuel elements cladding inspections in IPR-r1 TRIGA reactor

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, R.R.; Mesquita, A.Z.; Andrade, E.P.D.; Gual, Maritza R., E-mail: rrr@cdtn.br, E-mail: amir@cdtn.br, E-mail: edson@cdtn.br, E-mail: maritzargual@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2015-07-01

    It is in progress at the Centro de Desenvolvimento da Tecnologia Nuclear - CDTN (Nuclear Technology Development Center), a research project that aims to investigate possible leaks in the fuel elements of the TRIGA reactor, located in this research center. This paper presents the final form of sipping test device for TRIGA reactor, and results of the first experiments setup. Mechanical support strength tests were made by knotting device on the crane, charged with water from the conventional water supply, and tests outside the reactor pool with the use of new non-irradiated fuel elements encapsulated in stainless steel, and available safe stored in this unit. It is expected that tests with graphite elements from reactor pool are done soon after and also the test experiment with the first fuel elements in service positioned in the B ring (central ring) of the reactor core in the coming months. (author)

  2. Sipping test update device for fuel elements cladding inspections in IPR-r1 TRIGA reactor

    International Nuclear Information System (INIS)

    Rodrigues, R.R.; Mesquita, A.Z.; Andrade, E.P.D.; Gual, Maritza R.

    2015-01-01

    It is in progress at the Centro de Desenvolvimento da Tecnologia Nuclear - CDTN (Nuclear Technology Development Center), a research project that aims to investigate possible leaks in the fuel elements of the TRIGA reactor, located in this research center. This paper presents the final form of sipping test device for TRIGA reactor, and results of the first experiments setup. Mechanical support strength tests were made by knotting device on the crane, charged with water from the conventional water supply, and tests outside the reactor pool with the use of new non-irradiated fuel elements encapsulated in stainless steel, and available safe stored in this unit. It is expected that tests with graphite elements from reactor pool are done soon after and also the test experiment with the first fuel elements in service positioned in the B ring (central ring) of the reactor core in the coming months. (author)

  3. Utilization of a typical 250 kW TRIGA Mark II reactor at a University

    International Nuclear Information System (INIS)

    Villa, M.; Boeck, H.; Musilek, A.

    2007-01-01

    The 250 kW TRIGA Mark-II reactor operates since March 1962 at the Atominstitut Vienna/Austria. Its main tasks are nuclear education and training in the fields of neutron- and solid state physics, nuclear technology, reactor safety, radiochemistry, radiation protection and dosimetry, and low temperature physics and fusion research. Academic research is carried out by students in the above mentioned fields coordinated and supervised by about 70 staff members with the aim of a masters- or PhD degree in one of the above mentioned areas. During the past 15 years about 580 students graduated through the Atominstitut. In addition, the Atominstitut co-operates closely with the nearby located IAEA in research projects, coordinated research programs (CRP) and supplying expert services. Regular training courses are carried out for the IAEA for Safeguard Trainees, fellowship places are offered for scientists from developing countries and staff members carry out expert missions to research centres in Africa, Asia and South America. Special Nuclear Material (SNM) is stored for calibration purposes at the Atominstitut belonging to the IAEA. (author)

  4. Neutronics analysis of the proposed 25-MW leu TRIGA Multipurpose Research Reactor

    International Nuclear Information System (INIS)

    Nurdin, M.; Bretscher, M.M.; Snelgrove, J.L.

    1982-01-01

    More than two years ago the government of Indonesia announced plans to purchase a research reactor for the Puspiptek Research Center in Serpong Indonesia to be used for isotope production, materials testing, neutron physics measurements, and reactor operator training. Reactors using low-enriched uranium (LEU) plate-type and rod-type fuel elements were considered. This paper deals with the neutronic evaluation of the rod-type 25-MW LEU TRIGA Multipurpose Research Reactor (MPRR) proposed by the General Atomic Company of the United States of America

  5. Handling of TRIGA spent fuel at the Medical University of Hanover and its return to the United States

    International Nuclear Information System (INIS)

    Hampel, Gabriele; Harke, Heinrich; Kelm, Wieland; Klaus, Uwe

    2008-01-01

    The Medical University of Hannover (MHH) was taking part in the US Department of Energy's (DOE) 'Research Reactor Spent Fuel Acceptance Program' to return its 76 spent TRIGA fuel elements to the United States in the middle of 1999. The fuel elements have been moved to the Idaho National Engineering and Environmental Laboratory (INEEL) in Idaho. This paper describes the technical facilities for handling the fuel elements at the MHH and the various steps in removing the fuel elements from the reactor, transferring them to the transport cask and shipping them to the INEEL. (authors)

  6. Irradiation performance of experimental fast reactor 'JOYO' MK-1 driver fuel assemblies

    International Nuclear Information System (INIS)

    Itaki, Toshiyuki; Kono, Keiichi; Tachi, Hirokatsu; Yamanouchi, Sadamu; Yuhara, Shunichi; Shibahara, Itaru

    1985-01-01

    The experimental fast reactor ''JOYO'' completed it's breeder core (MK-I) operation in January 1982. The MK-I driver fuel assemblies were removed from the core sequencially in order of burnup increase and have been under postirradiation examination (PIE). The PIE has almost been completed for 30 assemblies including the highest burnup assemblies of 48,000 MWD/MTM. It has been confirmed that all fuel assemblies have exhibited satisfactory performance without detrimental assembly deformation or without any indications of fuel pin breach. The irradiation conditions of the MK-I core were somewhat more moderate than those conditions envisioned for prototypic reactor. However the results of the examination revealed the typical irradiation behavior of LMFBR fuels, although such characteristics were benign as compared with those anticipated in high burnup fuels. Systematic performance data have been accumulated through the fuel fabrication, irradiation and postirradiation examination processes. Based on these data, the MK-I fuel designing and fabrication techniques were totally confirmed. This technical experience and the associated insight into irradiation behavior have established a milestone to the next step of fast reactor fuel development. (author)

  7. Radiation protection in a university TRIGA reactor

    International Nuclear Information System (INIS)

    Tschurlovits, M. . Author

    2004-01-01

    Radiation protection in a university institute operating a research reactor and other installations has different constraints as a larger facility. This is because the legal requirements apply in full, but the potential of exposure is low, and accesses has to be made available for students, but also for temporary workers. Some of the problems in practical radiation protection are addressed and solutions are discussed. In addition, experience with national radiation protection legislation recently to be issued is addressed and discussed. (author)

  8. Thermal analysis of LEU modified Cintichem target irradiated in TRIGA reactor

    International Nuclear Information System (INIS)

    Catana, A; Toma, C.

    2009-01-01

    Actions conceived during last years at international level for conversion of Molybdenum fabrication process from HEU to LEU targets utilization created opportunities for INR to get access to information and participating to international discussions under IAEA auspices. Concrete steps for developing fission Molybdenum technology were facilitated. Institute of Nuclear Research bringing together a number of conditions like suitable irradiation possibilities, direct communication between reactor and hot cell facility, handling capacity of high radioactive sources, and simultaneously the existence of an expanding internal market, decided to undertake the necessary steps in order to produce fission molybdenum. Over the course of last years of efforts in this direction we developed the steps for fission Molybdenum technology development based on modified Cintichem process in accordance with the Argonne National Laboratory proved methodology. Progress made by INR to heat transfer computations of annular target using is presented. An advanced thermal-hydraulic analysis was performed to estimate the heat removal capability for an enriched uranium (LEU) foil annular target irradiated in TRIGA reactor core. As a result, the present analysis provides an upper limit estimate of the LEU-foil and external target surface temperatures during irradiation in TRIGA 14 MW reactor. (authors)

  9. Precision of neutron activation analysis for environmental biological materials

    International Nuclear Information System (INIS)

    Hamaguchi, Hiroshi; Iwata, Shiro; Koyama, Mutsuo; Sasajima, Kazuhisa; Numata, Yuichi.

    1977-01-01

    Between 1973 and 1974 a special committee ''Research on the application of neutron activation analysis to the environmental samples'' had been organized at the Research Reactor Institute, Kyoto University. Eleven research groups composed mainly of the committee members cooperated in the intercomparison programme of the reactor neutron activation analysis of NBS standard reference material, 1571 Orchard Leaves and 1577 Bovine Liver. Five different type of reactors were used for the neutron irradiation; i.e. KUR reactor of the Research Reactor Institute, Kyoto University, TRIGA MARK II reactor of the Institute for Atomic Energy, Rikkyo University, and JRR-2, JRR-3, JRR-4 reactor of Japan Atomic Energy Research Institute. Analyses were performed mainly by instrumental method. Precision of the analysis of 23 elements in Orchard Leaves and 13 elements in Bovine Liver presented by the different research groups was shown in table 4 and 5, respectively. The coefficient of variation for these elements was from several to -- 30 percent. Averages given to these elements agreed well with the NBS certified or reference values. Thus, from the practical point of view for the routine multielement analysis of environmental samples, the validity of the instrumental neutron activation technique for this purpose has been proved. (auth.)

  10. Report on results of utilizing nuclear reactor, April, 1983 - March, 1984

    International Nuclear Information System (INIS)

    1984-01-01

    The reactor in the Institute for Atomic Energy, Rikkyo University, is usually operated for 6 hours a day. It has been operated for 21 years without large trouble. The time of operation in fiscal year 1983 was 551 hours, and the cumulative power output was 47,511 kWh. From December, 1983, to March, 1984, the reactor was shut down, and the repair works for the secondary cooling system were carried out, accordingly, the power output and the number of utilization cases decreased. The total number of utilization cases in fiscal year 1983 was 2,702, and the total time of utilization was 8,497 hr 26 min. The utilization by universities accounted for 53.8%. A short period course was held as usual to educate and train 14 students. The radiation control for individuals and controlled areas is reported. The management of solid, gas end liquid wastes and their amounts being preserved in the Institute are reported. The radioactivity in environmental samples was measured 4 times in a year by total beta method, and the data on soil, sea bottom sediment, seawater and marine products are given. The summary of the research made by the personnel of the Institute and other achievement are also described. The execution of research in 1983 owed largely to the scientific research promotion fund of Japan Private School Promotion Foundation. The reactor was effectively utilized by the common utilization of the Rikkyo reactor. (Kako, I.)

  11. Development of Reactor TRIGA PUSPATI Simulator for Education and Training

    International Nuclear Information System (INIS)

    Mohd Sabri Minhat; Zarina Masood; Muhammad Rawi Mohamed Zin

    2016-01-01

    The real-time simulator for Reactor TRIGA PUSPATI (RTP) which is under development. The main purpose of this simulator is operator training and a dynamic test bed (DTB) to test and validate the control logics in reactor regulating system (RRS) of RTP. The simulator configuration is divided into hardware and software. The simulator hardware consists of a host computer, operator station, a network switch, control rod drive mechanism and a large display panel. The RTP hardwired panel is replicated similar to real console. The software includes a mathematical model includes reactor kinetics and thermal-hydraulics that implements plant dynamics in real-time using LabVIEW, an instructor station module work as host computer that manages user instructions, and a human machine interface module as a graphical user interface which is used in the real RTP plant. The developed TRIGA reactor simulators are installed in the Malaysian Nuclear Agency nuclear training center for reactor operator training. To use the simulator as a dynamic test-bed, the reactor regulating system modeling software of the simulator was replaced by actual RRS cabinet which is consist of Programmable Logic Controller (PLC) S7-1500, and was interfaced using a hard-wired and network-based interface. RRS cabinet generates control signals for reactor power control based on the various feedback signals from DTB such as neutron detector signal and control rod positions, and the DTB runs plant dynamics based on the RRS control signals. Thus the Hardware-In-the-Loop Simulation between RRS and the emulated plant (DTB) has been implemented and tested in this configuration. Normal and abnormal case test have been emulated for this project. In conclusion, the functions and the control performance of the developed RTP dynamic test bed simulator have been tested showing reasonable and acceptable results. (author)

  12. Simulation of the TRIGA-ININ reactor using EXT-2, in R-θ RΘ and temperature of 20 Centigrade

    International Nuclear Information System (INIS)

    Aguilar H, F.

    1983-10-01

    The simulation of the TRIGA-ININ reactor, it was beginning considering the more simple case (follower bars equal to fuel elements, cell bar transitory with vacuum, etc.), this it left tuning as the obtained results were observed and it was studied the literature with respect to this reactor, in the following step the followers are considered as standard elements but with 32 grams of U-235 and so forth until reaching to the configuration that is considered definitive. (Author)

  13. Conceptual design of fuel transfer cask for Reactor TRIGA PUSPATI (RTP)

    Energy Technology Data Exchange (ETDEWEB)

    Muhamad, Shalina Sheik [Prototype and Plant Development Center, Technical Support Division, Malaysian Nuclear Agency, Bangi, 43000, Kajang, Selangor (Malaysia); Hamzah, Mohd Arif Arif B. [Prototype and Plant Development Center, Technical Support Division Malaysian Nuclear Agency, Bangi, 43000, Kajang, Selangor (Malaysia)

    2014-02-12

    Spent fuel transfer cask is used to transfer a spent fuel from the reactor tank to the spent fuel storage or for spent fuel inspection. Typically, the cask made from steel cylinders that are either welded or bolted closed. The cylinder is enclosed with additional steel, concrete, or other material to provide radiation shielding and containment of the spent fuel. This paper will discuss the Conceptual Design of fuel transfer cask for Reactor TRIGA Puspati (RTP)

  14. Environmental impact assessment of Ar-41 released by the normal operation of TRIGA-Mark 2 research reactor

    International Nuclear Information System (INIS)

    Qassoud, D.; Soufi, I.; Ziagos, J.; Demir, Z

    2007-01-01

    Full text: In accordance with the international regulation of nuclear safety and radiological protection of the environment applicable to the basic nuclear installations, category in which the Triga-Mark 2 research reactor is considered, an assesment of the impact in to the environment of the Ar-41 radioelement is accomplished. This radioelement is released by the normal operation of this reactor. The assessment is based on the characteristics of a Moroccan site (where the reactor is installed). It is carried out using CEA Gaussian models and mathematical models developed in LLNL. Considering the assumptions of impact assessments of the radioactivity in the atmosphere, the most important exposure is relatively corresponding to 1 Km from the reactor. This exposure is approximately 0,07% of the lawful limit. Beyond this locality, the exposure becomes lower than 0,02% of this limit. Beyond 5 Km, it becomes lower than ten nono-Sivert. In the basis of the site radiological baseline, the environmental impact of Ar-41 released in normal operation of the reactor is negligible in the studied case. [fr

  15. Dose calculation in biological samples in a mixed neutron-gamma field at the TRIGA reactor of the University of Mainz

    DEFF Research Database (Denmark)

    Schmitz, T.; Blaickner, M.; Schütz, C.

    2010-01-01

    and pin-diodes. Material and methods. When L-α-alanine is irradiated with ionizing radiation, it forms a stable radical which can be detected by electron spin resonance (ESR) spectroscopy. The value of the ESR signal correlates to the amount of absorbed dose. The dose for each pellet is calculated using......To establish Boron Neutron Capture Therapy (BNCT) for non-resectable liver metastases and for in vitro experiments at the TRIGA Mark II reactor at the University of Mainz, Germany, it is necessary to have a reliable dose monitoring system. The in vitro experiments are used to determine the relative......-calculations for mixed radiation fields and the Hansen & Olsen alanine detector response model. With the acquired data about the background dose and charged particle spectrum, and with the acquired information of the neutron flux, we are capable of calculating the dose to the tissue. Conclusion. Monte Carlo simulation...

  16. Ageing Management in the CENM Triga Mark II Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    El Younoussi, C.; Nacir, B.; El Bakkari, B.; Boulaich, Y. [Centre for Nuclear Studies of Maâmora (CENM), National Centre of Energy Sciences and Nuclear Techniques (CNESTEN), Rabat (Morocco)

    2014-08-15

    Physical ageing is one of the most important factors that may reduce the safety margins calculated in the design of safety system components of a research reactor. In this context, special efforts are necessary for ensuring the safety of research reactors through appropriate ageing management actions. The paper deals with the overall aspects of the ageing management system of the Moroccan TRIGA Mark II research reactor. The management system covers among others, management of structures, critical components inspections, the control command system and nuclear instrumentation verification. The paper presents also how maintenance and periodic testing are organized and managed in the reactor module. Practical examples of ageing management actions of some systems and components during recent years are presented. (author)

  17. Vaporization Rate Analysis of Primary Cooling Water from Reactor PUSPATI TRIGA (RTP) Tank

    International Nuclear Information System (INIS)

    Tonny Anak Lanyau; Mohd Fazli Zakaria; Yahya Ismail

    2011-01-01

    Primary cooling system consists of pumps, heat exchangers, probes, a nitrogen-16 diffuser and associated valves is connected to the reactor TRIGA PUSPATI (RTP) tank by aluminium pipes. Both the primary cooling system and the reactor tank is filled with demineralized light water (H 2 O), which serves as a coolant, moderator as well as shielding. During reactor operation, vaporization in the reactor tank will reduce the primary water and contribute to the formation of vapor in the reactor hall. The vaporization may influence the function of the water subsequently may affect the safety of the reactor operation. It is essential to know the vaporization rate of the primary water to ensure its functionality. This paper will present the vaporization rate of the primary cooling water from the reactor tank and the influence of temperature of the water in the reactor tank to the vaporization rate. (author)

  18. 7. biennial U.S. TRIGA users' conference. Papers and abstracts

    International Nuclear Information System (INIS)

    1980-01-01

    The conference covers the following topics: new developments in the TRIGA system; uses of microprocessors in control and monitoring and measurement of TRIGA performance parameters; safeguards, emergency planning, reactor standards; research facilities, fuel tests and calculations; TRIGA reactor parameters: emergency training

  19. Experimental study of the temperature distribution in the TRIGA IPR-R1 Brazilian research reactor

    International Nuclear Information System (INIS)

    Mesquita, Amir Zacarias

    2005-01-01

    The TRIGA-IPR-R1 Research Nuclear Reactor has completed 44 years in operation in November 2004. Its initial nominal thermal power was 30 kW. In 1979 its power was increased to 100 kW by adding new fuel elements to the reactor. Recently some more fuel elements were added to the core increasing the power to 250 kW. The TRIGA-IPR-R1 is a pool type reactor with a natural circulation core cooling system. Although the large number of experiments had been carried out with this reactor, mainly on neutron activation analysis, there is not many data on its thermal-hydraulics processes, whether experimental or theoretical. So a number of experiments were carried out with the measurement of the temperature inside the fuel element, in the reactor core and along the reactor pool. During these experiments the reactor was set in many different power levels. These experiments are part of the CDTN/CNEN research program, and have the main objective of commissioning the TRIGA-IPR-R1 reactor for routine operation at 250 kW. This work presents the experimental and theoretical analyses to determine the temperature distribution in the reactor. A methodology for the calibration and monitoring the reactor thermal power was also developed. This methodology allowed adding others power measuring channels to the reactor by using thermal processes. The fuel thermal conductivity and the heat transfer coefficient from the cladding to the coolant were also experimentally valued. lt was also presented a correlation for the gap conductance between the fuel and the cladding. The experimental results were compared with theoretical calculations and with data obtained from technical literature. A data acquisition and processing system and a software were developed to help the investigation. This system allows on line monitoring and registration of the main reactor operational parameters. The experiments have given better comprehension of the reactor thermal-fluid dynamics and helped to develop numerical

  20. Computational analysis of neutronic parameters for TRIGA Mark-II research reactor using evaluated nuclear data libraries

    International Nuclear Information System (INIS)

    Uddin, M.N.; Sarker, M.M.; Khan, M.J.H.; Islam, S.M.A.

    2010-01-01

    The aim of this study is to analyze the neutronic parameters of TRIGA Mark-II research reactor using the chain of NJOY-WIMS-CITATION computer codes based on evaluated nuclear data libraries CENDL-2.2 and JEFF-3.1.1. The nuclear data processing code NJOY99.0 has been employed to generate the 69 group WIMS library for the isotopes of TRIGA core. The cell code WIMSD-5B was used to generate the cross sections in CITATION format and then 3-dimensional diffusion code CITTATION was used to calculate the neutronic parameters of the TRIGA Mark-II research reactor. All the analyses were performed using the 7-group macroscopic cross section library. The CITATION test-runs using different cross section sets based on different models applied in WIMS calculations have shown a strong influence of those models on the final integral parameters. Some of the cells were specially treated with PRIZE options available in WIMSD-5B to take into account the fine structure of the flux gradient in the fuel-reflector interface region. It was observed that two basic parameters, the effective multiplication factor, k eff and the thermal neutron flux, were in good agreement among the calculated results with each other as well as the measured values. The maximum power densities at the hot spot were 1.0446E02 W/cc and 1.0426E02 W/cc for the libraries CENDL-2.2 and JEFF-3.1.1 respectively. The calculated total peaking factors 5.793 and 5.745 were compared to the original SAR value of 5.6325 as well as MCNP result. Consequently, this analysis will be helpful to enhance the neutronic calculations and also be used for the further thermal-hydraulics study of the TRIGA core.

  1. Applicable regulations and development of surveillance experiments of criticality approach in the TRIGA III Mark reactor

    International Nuclear Information System (INIS)

    Gonzalez M, J.L.; Aguilar H, F.; Rivero G, T.; Sainz M, E.

    2000-01-01

    In the procedure elaborated to repair the vessel of TRIGA III Mark reactor is required to move toward two tanks of temporal storage the fuel elements which are in operation and the spent fuel elements which are in decay inside the reactor pool. The National Commission of Nuclear Safety and Safeguards (CNSNS) has requested as protection measure that it is carried out a surveillance of the criticality approach of the temporal storages. This work determines the main regulation aspects that entails an experiment of criticality approach, moreover, informing about the results obtained in the developing of this experiments. The regulation aspects are not exclusives for this work in the TRIGA Mark III reactor but they also apply toward any assembling of fissile material. (Author)

  2. A spare-parts inventory program for TRIGA reactors

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, T V; Ringle, J C; Johnson, A G [Oregon State University (United States)

    1974-07-01

    As is fairly common with new reactor facilities, we had a few spare parts on hand as part of our original purchase when the OSU TRIGA first went critical in March of 1967. Within a year or so, however, it became apparent that we should critically examine our spare parts inventory in order to avoid unnecessary or prolonged outages due to lack of a crucial piece of equipment. Many critical components (those which must be present and operable according to our license or technical specifications) were considered, and a priority list of acquiring these was established. This first list was drawn up in March, 1969, two years after initial criticality, and some key components were ordered. The availability of funds was the overriding restriction then and now. This spare-parts list is reviewed and new components purchased annually; the average amount spent has been about $2,000 per year. This inventory has proved invaluable more than once; without it, we would have had lengthy shutdowns awaiting the arrival of the needed component. The sobering thought, however, is that our spare-parts inventory is still not complete-far from it, in fact, because this would be prohibitively expensive. It is very difficult to guess with 100% accuracy just which component might need replacing, and your $10,000 inventory of spare parts is useless in that instance if it doesn't include the needed part. An idea worth considering is to either (a) encourage General Atomic, through the collective voice of all TRIGA owners, to maintain a rather complete inventory of replacement parts, or (b) maintain an owner's spare-parts pool, financed by contributions from all the facilities. If either of these pools was established, the needed part could reach any facility within the U.S. within a few days, minimizing reactor outage time. (author)

  3. A spare-parts inventory program for TRIGA reactors

    International Nuclear Information System (INIS)

    Anderson, T.V.; Ringle, J.C.; Johnson, A.G.

    1974-01-01

    As is fairly common with new reactor facilities, we had a few spare parts on hand as part of our original purchase when the OSU TRIGA first went critical in March of 1967. Within a year or so, however, it became apparent that we should critically examine our spare parts inventory in order to avoid unnecessary or prolonged outages due to lack of a crucial piece of equipment. Many critical components (those which must be present and operable according to our license or technical specifications) were considered, and a priority list of acquiring these was established. This first list was drawn up in March, 1969, two years after initial criticality, and some key components were ordered. The availability of funds was the overriding restriction then and now. This spare-parts list is reviewed and new components purchased annually; the average amount spent has been about $2,000 per year. This inventory has proved invaluable more than once; without it, we would have had lengthy shutdowns awaiting the arrival of the needed component. The sobering thought, however, is that our spare-parts inventory is still not complete-far from it, in fact, because this would be prohibitively expensive. It is very difficult to guess with 100% accuracy just which component might need replacing, and your $10,000 inventory of spare parts is useless in that instance if it doesn't include the needed part. An idea worth considering is to either (a) encourage General Atomic, through the collective voice of all TRIGA owners, to maintain a rather complete inventory of replacement parts, or (b) maintain an owner's spare-parts pool, financed by contributions from all the facilities. If either of these pools was established, the needed part could reach any facility within the U.S. within a few days, minimizing reactor outage time. (author)

  4. Some information about the radiological protection concerning the TRIGA spent fuel handling at the Medical University of Hanover

    International Nuclear Information System (INIS)

    Hampel, Gabriele; Harke, Heinrich; Klaus, Uwe; Loercher, Gunther

    2008-01-01

    The Medical University of Hanover (MHH) returned its 76 spent TRIGA fuel elements to the United States in summer of 1999. For the transportation inside the MHH control areas were installed outside the reactor area, along the transfer route in the department of nuclear medicine and in the temporary building. During fuel handling at MHH a lot of radiation protection measures were necessary. This paper presents methods and results of the radiological protection measurements. (authors)

  5. 3 MW TRIGA Research Reactor facility of BAEC and its Utilization

    International Nuclear Information System (INIS)

    Molla, N.I.; Bhuiyan, S.I.; Wadud Mondal, M.A.; Ahmed, F.U.; Islam, M.N.; Hossain, S.M.; Ahmed, K.; Zulquarnain, A.; Abedin, Z.

    1999-01-01

    The paper briefly describes the Utilisation of 3 MW TRIGA Research Reactor of BAEC for neutron beam research, neutron activation analysis are isotope production. It includes the installation of the triple axis neutron spectrometer at the radial piercing beam port and a neutron radiography set-up at the tangential beam port and their uses for material analysis and condensed matter research and material testing. Nuclear and magnetic structures of some ferrites have been studied in powder diffraction method in the double axis mode. SANS technique with double crystal diffraction known as Bonse and Hart's method has been adopted in an experiment with alumina sample. The neutron radiography set-up and its use in the detection of corrosion in alumina have been reported. Determination of arsenic concentration in drinking water from tube well via Instrumental Neutron Activation Analysis and production of radioiodine-131 by dry distillation method are presented. Our experience on the removal of N-16 decay tank because of the leakage of coolant and bringing the research reactor back to operational by-passing the decay tank have been focussed. A possible reconfiguration of the existing TRIGA core, without exceeding the safety margins, providing additional irradiation channel and upgrading the neutron flux for increased radioisotope production has been attempted. Cross section library ENDF/B-VI and JENDL3.2, code NJOY94.10, WIMSD package, 3-D code CITATION, PARET and Monte Carlo code MCNP4B2 have been employed to achieve the objective. (author)

  6. A digital data acquisition and display system for ITU TRIGA Mark II reactor

    International Nuclear Information System (INIS)

    Can, B.; Omuz, S.

    2008-01-01

    Full text: In this study, a digital data acquisition and display system realized for ITU TRIGA Mark-II Reactor is described. This system is realized in order to help the reactor operator and to increase reactor console capacity. The system consists of two main units, which are host computers and RTI-815F, analog devices, data acquisition card. RTI-815F is multi-function analog/digital input/output board that plugs into one of the available long expansion slots in the IBM-PC, PC/XT, PC/AT, or equivalent personal computers. It has 16 analog input channels for single-ended input signals or 8 analog input channels for differential input signals. But its channel capacity can be increased to 32 input channels for single-ended input signals or 16 input channels for differential input signals. RTI-815F board contains 2 analog output channels, 8 digital input channels and 8 digital output channels. In the ITD TRIGA Mark-II Reactor, 6 fuel temperature channels, 3 water temperature channels, 3 control rod position channels and 4 power channels are chosen as analog input signals for RTI-815F. Its digital outputs are assigned to cooling tower fan, primary and secondary pump reactor scram, control rod rundown. During operation, data are automatically archived to disk and displayed on screen. The channel selection time and sampling time can be adjusted. The simulated movement and position of control rods in the reactor core can be noted and displayed. The changes of power, fuel temperature and water temperature can be displayed on the screen as a graphic. In this system both period and reactivity are calculated and displayed on the screen. (authors)

  7. Assessment of a RELAP5 model for the IPR-R1 TRIGA research reactor

    International Nuclear Information System (INIS)

    Reis, Patricia A.L.; Costa, Antonella L.; Pereira, Claubia; Veloso, Maria A.F.; Mesquita, Amir Z.; Soares, Humberto V.

    2010-01-01

    RELAP5 code was developed at the Idaho National Environmental and Engineering Laboratory and it is widely used for thermal hydraulic studies of commercial nuclear power plants and, currently, it has been also applied for thermal hydraulic analysis of nuclear research systems with good predictions. This work is a contribution to the assessment of RELAP5/3.3 code for research reactors analysis. It presents steady-state and transient calculation results performed using a RELAP5 model to simulate the IPR-R1 TRIGA research reactor conditions operating at 50 and 100 kW. The reactor is located at the Nuclear Technology Development Centre (CDTN), Brazil. The development and the assessment of a RELAP5 model for the IPR-R1 TRIGA are presented. Experimental data were considered in the process of code-to-data validation. The RELAP5 results were also compared with calculation performed using the STHIRP-1 (Research Reactors Thermal Hydraulic Simulation) code. The use of a cross flow model has been essential to improve results in the transient condition respect to preceding investigations.

  8. TRIGASIM: A computer program to simulate a TRIGA Mark I Reactor

    International Nuclear Information System (INIS)

    Ruby, Lawrence

    1992-01-01

    A Fortran-77 computer program has been written which simulates the operation of a TRIGA Mark I Reactor. The 'operator' has options at 1-second intervals, of raising rods, lowering rods, maintaining rods steady, dropping a rod, or scramming the reactor. Results are printed to the screen, and to 2 output files - a tabular record and a logarithmic plot of the power. The Point Kinetic Equations are programmed with 6 delayed groups, quasi-static power feedback, and forward differencing. A pulsing option is available, with simulation which employs the Fuchs Model. A pulse-tail model has been devised to simulate behavior for a few minutes following a pulse. Both graphic and tabular output are also available for the pulses. (author)

  9. Supervisory system to monitor the neutron flux of the IPR-R1 TRIGA research reactor at CDTN

    International Nuclear Information System (INIS)

    Pinto, Antonio Juscelino; Mesquita, Amir Zacarias; Tello, Cledola Cassia Oliveira

    2009-01-01

    The IPR-R1 TRIGA Mark I nuclear research reactor at the Nuclear Technology Development Center - CDTN (Belo Horizonte) is a pool type reactor. It was designed for research, training and radioisotope production. The International Atomic Energy Agency- IAEA - recommends the use of friendly interfaces for monitoring and controlling the operational parameters of nuclear reactors. This paper reports the activities for implementing a supervisory system, using LabVIEW software, with the purpose to provide the IPR-R1 TRIGA research reactor with a modern, safe and reliable system to monitor the time evolution of the power of its core. The use of the LabVIEW will introduce modern techniques, based on electronic processor and visual interface in video monitor, substituting the mechanical strip chart recorders (ink-pen drive and paper) that monitor the current neutrons flux, which is proportional to the thermal power supplied by reactor core. The main objective of the system will be to follow the evolution of the neutronic flux originated in the Linear and Logarithmic channels. A great advantage of the supervisory software nowadays, in relation to computer programs currently used in the facility, is the existence of new resources such as the data transmission and graphical interfaces by net, grid lines display in the graphs, and resources for real time reactor core video recordings. The considered system could also in the future be optimized, not only for data acquisition, but also for the total control of IPR-R1 TRIGA reactor(author)

  10. 5. European conference of TRIGA users. Papers and abstracts

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1978-07-01

    The main conference topics were: Operation and maintenance experience of the TRIGA reactors; Development of new Low Enrichment Fuels (LEU); Dose assessments noble gas releases; Radiation protection and dosimetry measurements; Research reactors programs and experiments; and Application of TRIGA reactors.

  11. 5. European conference of TRIGA users. Papers and abstracts

    International Nuclear Information System (INIS)

    1978-01-01

    The main conference topics were: Operation and maintenance experience of the TRIGA reactors; Development of new Low Enrichment Fuels (LEU); Dose assessments noble gas releases; Radiation protection and dosimetry measurements; Research reactors programs and experiments; and Application of TRIGA reactors

  12. Experiences in controlling the upgrading of TRIGA 2000 Bandung reactor

    International Nuclear Information System (INIS)

    Huda, K.; Wibowo, Y.W.; Suprawhardana, M.S.

    2001-01-01

    TRIGA 2000 Bandung Reactor was established in 1961 for research, education and isotope production purposes. The reactor reached its first criticality in October 1964 and operated at nominal power of 250 kW until 1971. In 1971 the reactor was upgraded to the power level of 1000 kW. In order to raise the capacity of isotope production, the reactor has been upgraded again to the power level of 2000 kW. During the modification of the reactor, the Center for Research and Development of Nuclear Techniques (CRDNT) was management of the reactor as it faced many problems, either technical or non-technical ones. This caused the upgrading activities to take a long time. At this time, the reactor upgrading has almost finished, and the nuclear commissioning is going on. Several aspects and problems associated with the upgrading process have been reviewed and the results are discussed in the present paper. (author)

  13. Operating experiences at the Finnish TRIGA reactor

    International Nuclear Information System (INIS)

    Salmenhaara, Seppo

    1988-01-01

    The Finnish TRIGA reactor has been in operation since March 1962. There are still 57 original Al-clad fuel elements in the core. So far we have had only two fuel cladding failures in 1981 and 1988. The first one was an Al-clad element and the second one a SS-clad. The low rate of fuel cladding failures has made it possible to use continuously also the Al-clad fuel elements. Although some conventional irradiations of certain type have been repeated successfully tens of times, new and unexpected incidents can still take place. As an example an event of a leaking irradiation capsule is described

  14. Neutron flux measurements at the TRIGA reactor in Vienna for the prediction of the activation of the biological shield

    International Nuclear Information System (INIS)

    Merz, Stefan; Djuricic, Mile; Villa, Mario; Boeck, Helmuth; Steinhauser, Georg

    2011-01-01

    The activation of the biological shield is an important process for waste management considerations of nuclear facilities. The final activity can be estimated by modeling using the neutron flux density rather than the radiometric approach of activity measurements. Measurement series at the TRIGA reactor Vienna reveal that the flux density next to the biological shield is in the order of 10 9 cm -2 s -1 at maximum power; but it is strongly influenced by reactor installations. The data allow the estimation of the final waste categorization of the concrete according to the Austrian legislation. - Highlights: → Neutron activation is an important process for the waste management of nuclear facilities. → Biological shield of the TRIGA reactor Vienna has been topic of investigation. → Flux values allow a categorization of the concrete concerning radiation protection legislation. → Reactor installations are of great importance as neutron sources into the biological shield. → Every installation shows distinguishable flux profiles.

  15. Detection and location of leaking TRIGA fuel elements

    International Nuclear Information System (INIS)

    Bouchey, G.D.; Gage, S.J.

    1970-01-01

    Several TRIGA facilities have experienced difficulty resulting from cladding failures of aluminum clad TRIGA fuel elements. Recently, at the University of Texas at Austin reactor facility, fission product releases were observed during 250 kW operation and were attributed to a leaking fuel element. A rather extensive testing program has been undertaken to locate the faulty element. The used sniffer device is described, which provides a quick, easily constructed, and extremely sensitive means of locating leaking fuel elements. The difficulty at The University of Texas was compounded by extremely low levels and the sporadic nature of the releases. However, in the more typical situation, in which a faulty element consistently releases relatively large quantities of fission gas, such a device should locate the leak with little difficulty

  16. Neutron radiography applications in I.T.U. TRIGA Mark-II reactor

    International Nuclear Information System (INIS)

    Tugrul, A. B.

    2002-01-01

    Neutron radiography is an important radiographic technique which is supplied different and advanced information according to the X or gamma ray radiography. However, it has a trouble for supplying the convenient neutron sources. Tangential beam tube of Istanbul Technical University (ITU) TRIGA Mark-II Training and Research Reactor has been arranged for using neutron radiography. The neutron radiography set defined as detailed for the application of the technique. Two different techniques for neutron radiography are defined as namely, transfer method and direct method. For the transfer method dysprosium and indium screens are used in the study. But, dysprosium generally was preferred in many studies in the point of view nuclear safety. Gadolinium was used for direct method. Two techniques are compared and explained the preferring of the transfer technique. Firstly, reference composition is prepared for seeing the differences between neutron and X-ray or gamma radiography. In addition of it, some radiograph samples are given neutron and X-ray radiography which shows the different image characters. Lastly, some examples are given from archaeometric studies. One of them the brass plates of Great Mosque door in Cizre. After the neutron radiography application, organic dye traces are noticed. Other study is on a sword that belong to Urartu period at the first millennium B.C. It is seen that some wooden part on it. Some different artefacts are examined with neutron radiography from the Ikiztepe excavation site, then some animal post parts are recognized on them. One of them is sword and sheath which are corroded together. After the neutron radiography application, it can be noticed that there are a cloth between the sword and its sheath. By using neutron radiography, many interesting and detailed results are observed in ITU TRIGA Mark-II Training and Research Reactor. Some of them shouldn't be recognised by using any other technique

  17. 12. U.S. TRIGA users conference. Papers and abstracts

    International Nuclear Information System (INIS)

    1990-01-01

    The Conference presentations were devoted to the following topics: new developments and improvements, including modifications of TRIGA reactors and equipment; experiments with TRIGA reactors (Neutron Radiography); radiochemistry, radioisotope production and beam irradiations (experiment applications, simulation); reactor physics - fuel utilization; reactor operation and maintenance experience; safety aspects, licensing and radiation protection

  18. Improved measurements of thermal power and control rods using multiple detectors at the TRIGA Mark II reactor in Ljubljana

    International Nuclear Information System (INIS)

    Zerovnik Gasper; Snoj Luka; Trkov Andrej; Barbot Loic; Fourmentel Damien; Villard Jean-Francois

    2013-06-01

    The aim of the current bilateral project between CEA Cadarache and JSI is to improve the accuracy of the online thermal power monitoring at the JSI TRIGA reactor. Simultaneously, a new wide range multichannel acquisition system for fission chambers, recently developed by CEA, is tested. In the paper, calculational and experimental power calibration methods are described. The focus is on use of multiple detectors in combination with pre-calculated and pre-measured control rod- position-dependent correction factors to improve the reactor power reading. The system will be implemented and tested at the JSI TRIGA reactor in 2014. (authors)

  19. Operation and reactivity measurements of an accelerator driven subcritical TRIGA reactor

    Science.gov (United States)

    O'Kelly, David Sean

    Experiments were performed at the Nuclear Engineering Teaching Laboratory (NETL) in 2005 and 2006 in which a 20 MeV linear electron accelerator operating as a photoneutron source was coupled to the TRIGA (Training, Research, Isotope production, General Atomics) Mark II research reactor at the University of Texas at Austin (UT) to simulate the operation and characteristics of a full-scale accelerator driven subcritical system (ADSS). The experimental program provided a relatively low-cost substitute for the higher power and complexity of internationally proposed systems utilizing proton accelerators and spallation neutron sources for an advanced ADSS that may be used for the burning of high-level radioactive waste. Various instrumentation methods that permitted ADSS neutron flux monitoring in high gamma radiation fields were successfully explored and the data was used to evaluate the Stochastic Pulsed Feynman method for reactivity monitoring.

  20. Specialist committee's review reports for experimental fast reactor JOYO' MK-III performance tests

    International Nuclear Information System (INIS)

    Yamashita, Kiyonobu; Okubo, Toshiyuki; Kamide, Hideki

    2004-02-01

    Performance tests (startup-physics tests and power elevation tests) were planed for experimental fast reactor 'JOYO' MK-III where irradiation performances were upgraded by power increase from 100 to 140 MW. The reactor safety committee of O-arai Engineering Center has established a specialist committee for 'JOYO' MK-III Performance Tests at the first meeting of 2003 on 23th. April 2003, to accomplish the tests successfully. Subjects of the specialist committee were reviews of following items covering a wide range. 1) Contents of modification works. 2) Reflections of functional test results to the plant and facilities. 3) Reflections of safety rule modification to instruction and manual for operation. 4) Quality assurances and pre-calculation for performance test. 5) Inspection plan and its results. 6) Adequacy of performance test plan. 7) Confirmation of performance test results. Before test-starts, the specialist committee has confirmed by reviewing the items from 1) to 6) based on explanations and documents of the Division of Experimental Reactor, that the test plan and pre-inspections are adequate. After the tests, the specialist committee had confirmed by reviewing the item 7) in the same way, that the each test result satisfies the corresponding criterion. The specialist committee has concluded from these review's results before and after the tests that the 'JOYO' MK-III Performance Tests were carried out appropriately. Besides, the first criticality of the JOYO MK-III was achieved on 2nd. July 2003, and the continuous full power operation was carried on 20th. Nov. 2003. Finally, all performance tests were completed by the pass of the last governmental pre-serviced inspection (dose rate measurement during the shut down condition). (author)

  1. Principle of human system interface (HSI) design for new reactor console of PUSPATI TRIGA Reactor (RTP)

    International Nuclear Information System (INIS)

    Zareen Khan Abdul Jalil Khan; Ridzuan Abdul Mutalib; Mohd Idris Taib; Mohd Khairulezwan Abdul Manan; Nurfarhana Ayuni Joha; Mohd Sabri Minhat; Izhar Abu Hussin

    2013-01-01

    Full-text: This paper will describe the principle of human system interface design for new reactor console in control room at TRIGA reactor facility. In order to support these human system interface challenges in digital reactor console. Software-based instrumentation and control (I and C) system for new reactor console could lead to new human machine integration. The proposed of Human System Interface (HSI) which included the large display panels which shows reactor status, compact and computer-based workstations for monitoring, control and protection function. The proposed Human System Interface (HIS) has been evaluated using various human factor engineering. It can be concluded that the Human System Interface (HIS) is designed as to address the safety related computer controlled system. (author)

  2. Neutronics analysis of TRIGA Mark II research reactor

    Directory of Open Access Journals (Sweden)

    Haseebur Rehman

    2018-02-01

    Full Text Available This article presents clean core criticality calculations and control rod worth calculations for TRIGA (Training, Research, Isotope production-General Atomics Mark II research reactor benchmark cores using Winfrith Improved Multi-group Scheme-D/4 (WIMS-D/4 and Program for Reactor In-core Analysis using Diffusion Equation (PRIDE codes. Cores 133 and 134 were analyzed in 2-D (r, θ and 3-D (r, θ, z, using WIMS-D/4 and PRIDE codes. Moreover, the influence of cross-section data was also studied using various libraries based on Evaluated Nuclear Data File (ENDF/B-VI.8 and VII.0, Joint Evaluated Fission and Fusion File (JEFF-3.1, Japanese Evaluated Nuclear Data Library (JENDL-3.2, and Joint Evaluated File (JEF-2.2 nuclear data. The simulation results showed that the multiplication factor calculated for all these data libraries is within 1% of the experimental results. The reactivity worth of the control rods of core 134 was also calculated with different homogenization approaches. A comparison was made with experimental and reported Monte Carlo results, and it was found that, using proper homogenization of absorber regions and surrounding fuel regions, the results obtained with PRIDE code are significantly improved.

  3. Evaluation Of Fire Safety And Protection At PUSPATI TRIGA Reactor (RTP)

    International Nuclear Information System (INIS)

    Ahmad Nabil Ab Rahim; Alfred Sanggau Ligam; Nurhayati Ramli; Mohd Fazli Zakaria; Naim Syauqi Hamzah; Phongsakorn Prak; Mohammad Suhaimi Kassim; Zarina Masood

    2014-01-01

    Fire hazard is one of many risks that can affect the safety operation of PUSPATI TRIGA Reactor. Reactor building in Malaysian Nuclear Agency was built in 1980s and the fire system has been introduced since then. The evaluation of the fire safety system at this time is important to ensure the efficiency of fire prevention, fighting and mitigation task that probably occurs. This evaluation involves with the fire fighting system and equipment, integrity of the system from the perspective of management and equipment, fire fighting procedure and fire fighting response team. (author)

  4. Technology development and demonstration for TRIGA research reactor decontamination, decommissioning and site restoration

    International Nuclear Information System (INIS)

    Oh, Won Zin; Jung, Ki Jung; Lee, Byung Jik

    1997-01-01

    This paper describes the introduction to research reactor decommissioning plan at KAERI, the background of technology development and demonstration, and the current status of the system decontamination technology for TRIGA reactors, concrete decontamination and dust treatment technologies, wall ranging robot and graphic simulation of dismantling processes, soil decontamination and restoration technology, recycling or reuse technologies for radioactive metallic wastes, and incineration technology demonstration for combustible wastes. 9 figs

  5. Measurements of thermal and fast neutron fluxes at the TRIGA reactor

    International Nuclear Information System (INIS)

    Zerdin, F.; Grabovsek, Z.; Klinc, T.; Solinc, H.

    1966-01-01

    Gold foils were placed at different positions in the TRIGA reactor core and in the experimental devices. Absolute values of the thermal neutron flux at these positions were obtained by coincidence method. Preliminary fast neutron spectrum was measured by threshold detector and by 'Li 6 sandwich' detector. A short description of the applied method and obtained measurements results are included [sl

  6. DOE University Reactor Sharing Program. Final technical report for 1996--1997

    International Nuclear Information System (INIS)

    Chappas, W.J.; Adams, V.G.

    1998-01-01

    The Department of Energy University Reactor Sharing Program at University of Maryland, College Park (UMCP) has, once again, stimulated a broad use of the reactor and radiation facilities by undergraduate and graduate students, visitors, and professionals. Participants are exposed to topics such as nuclear engineering, radiation safety, and nuclear reactor operations. This information is presented through various means including tours, slide presentations, experiments, and discussions. Student research using the MUTR is also encouraged. In addition, the Reactor Sharing Program here at the University of Maryland does not limit itself to the confines of the TRIGA reactor facility. Incorporated in the program are the Maryland University Radiation Effects Laboratory, and the UMCP 2 x 4 Thermal Hydraulic Loop. These facilities enhance and give an added dimension to the tours and experiments. The Maryland University Training Reactor (MUTR) and the associated laboratories are made available to any interested institution six days a week on a scheduled basis. Most institutions are scheduled at the time of their first request--a reflection of their commitment to the Reactor Sharing Program. The success of the past years by no means guarantees future success. Therefore, the reactor staff is more aggressively pursuing its outreach program, especially with junior colleges and universities without reactor or radiation facilities; more aggressively developing demonstration and training programs for students interested in careers in nuclear power and radiation technology; and more aggressively up-grading the reactor facilities--not only to provide a better training facility but to prepare for relicensing in the year 2000

  7. 3. TRIGA owners' conference. Papers and abstracts

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1974-07-01

    The TRIGA Owners' Conference III was held February 25-27, 1974, in Albuquerque, New Mexico. Seventy representatives were in attendance from 26 TRIGA facilities in the United States, Mexico, Puerto Rico, Indonesia, and from interested government agencies and industrial concerns. The main topics, discussed at the Conference were: TRIGA operating experiences; analytical and experimental methods; limits on effluents release for research reactor; and TRIGA modifications.

  8. 3. TRIGA owners' conference. Papers and abstracts

    International Nuclear Information System (INIS)

    1974-01-01

    The TRIGA Owners' Conference III was held February 25-27, 1974, in Albuquerque, New Mexico. Seventy representatives were in attendance from 26 TRIGA facilities in the United States, Mexico, Puerto Rico, Indonesia, and from interested government agencies and industrial concerns. The main topics, discussed at the Conference were: TRIGA operating experiences; analytical and experimental methods; limits on effluents release for research reactor; and TRIGA modifications

  9. Experimental research in neutron physic and thermal-hydraulic at the CDTN Triga reactor

    Energy Technology Data Exchange (ETDEWEB)

    Mesquita, Amir Z.; Souza, Rose Mary G.P.; Ferreira, Andrea V.; Pinto, Antonio J.; Costa, Antonio C.L.; Rezende, Hugo C., E-mail: amir@cdtn.b, E-mail: souzarm@cdtn.b, E-mail: avf@cdtn.b, E-mail: ajp@cdtn.b, E-mail: aclc@cdtn.b, E-mail: hcr@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    The IPR-R1 TRIGA (Training, Research, Isotopes production, General Atomics) at Nuclear Technology Development Center (CDTN) is a pool type reactor cooled by natural circulation of light water and an open surface. TRIGA reactors, developed by General Atomics (GA), are the most widely used research reactor in the world and characterized by inherent safety. The IPR-R1 is the only Brazilian nuclear research reactor available and able to perform experiments in which interaction between neutronic and thermal-hydraulic areas occurs. The IPR-R1 has started up on November 11th, 1960. At that time the maximum thermal power was 30 kW. The present forced cooling system was built in the 70th and the power was upgraded to 100 kW. Recently the core configuration and instrumentation was upgraded again to 250 kW at steady state, and is awaiting the license of CNEN to operate definitely at this new power. This paper describes the experimental research project carried out in the IPR-R1 reactor that has as objective evaluate the behaviour of the reactor operational parameters, and mainly to investigate the influence of temperature on the neutronic variables. The research was supported by Research Support Foundation of the State of Minas Gerais (FAPEMIG) and Brazilian Council for Scientific and Technological Development (CNPq). The research project meets the recommendations of the IAEA, for safety, modernization and development of strategic plan for research reactors utilization. This work is in line with the strategic objectives of Brazil, which aims to design and construct the Brazilian Multipurpose research Reactor (RMB). (author)

  10. Experimental research in neutron physic and thermal-hydraulic at the CDTN Triga reactor

    International Nuclear Information System (INIS)

    Mesquita, Amir Z.; Souza, Rose Mary G.P.; Ferreira, Andrea V.; Pinto, Antonio J.; Costa, Antonio C.L.; Rezende, Hugo C.

    2011-01-01

    The IPR-R1 TRIGA (Training, Research, Isotopes production, General Atomics) at Nuclear Technology Development Center (CDTN) is a pool type reactor cooled by natural circulation of light water and an open surface. TRIGA reactors, developed by General Atomics (GA), are the most widely used research reactor in the world and characterized by inherent safety. The IPR-R1 is the only Brazilian nuclear research reactor available and able to perform experiments in which interaction between neutronic and thermal-hydraulic areas occurs. The IPR-R1 has started up on November 11th, 1960. At that time the maximum thermal power was 30 kW. The present forced cooling system was built in the 70th and the power was upgraded to 100 kW. Recently the core configuration and instrumentation was upgraded again to 250 kW at steady state, and is awaiting the license of CNEN to operate definitely at this new power. This paper describes the experimental research project carried out in the IPR-R1 reactor that has as objective evaluate the behaviour of the reactor operational parameters, and mainly to investigate the influence of temperature on the neutronic variables. The research was supported by Research Support Foundation of the State of Minas Gerais (FAPEMIG) and Brazilian Council for Scientific and Technological Development (CNPq). The research project meets the recommendations of the IAEA, for safety, modernization and development of strategic plan for research reactors utilization. This work is in line with the strategic objectives of Brazil, which aims to design and construct the Brazilian Multipurpose research Reactor (RMB). (author)

  11. Perturbation analysis of the TRIGA Mark II reactor Vienna

    Energy Technology Data Exchange (ETDEWEB)

    Khan, R. [Pakistan Institute of Engineering and Applied Sciences (PIEAS), Islamabad (Pakistan); Villa, M.; Stummer, T.; Boeck, H. [Vienna Univ. of Technology (Austria). Atominstitut; Saeedbadshah [International Islamic Univ., Islamabad (Pakistan)

    2013-04-15

    The safety design of a nuclear reactor needs to maintain the steady state operation at desired power level. The safe and reliable reactor operation demands the complete knowledge of the core multiplication and its changes during the reactor operation. Therefore it is frequently of interest to compute the changes in core multiplication caused by small disturbances in the field of reactor physics. These disturbances can be created either by geometry or composition changes of the core. Fortunately if these changes (or perturbations) are very small, one does not have to repeat the reactivity calculations. This article focuses the study of small perturbations created in the Central Irradiation Channel (CIC) of the TRIGA mark II core to investigate their reactivity influences on the core reactivity. For this purpose, 3 different kinds of perturbations are created by inserting 3 different samples in the CIC. The cylindrical void (air), heavy water (D2O) and Cadmium (Cd) samples are inserted into the CIC separately to determine their neutronics behavior along the length of the core. The Monte Carlo N-Particle radiation transport code (MCNP) is applied to simulate these perturbations in the CIC. The MCNP theoretical predictions are verified by the experiments performed on the current reactor core. The behavior of void in the whole core and its dependence on position and water fraction is also presented in this article. (orig.)

  12. Benchmarking criticality analysis of TRIGA fuel storage racks.

    Science.gov (United States)

    Robinson, Matthew Loren; DeBey, Timothy M; Higginbotham, Jack F

    2017-01-01

    A criticality analysis was benchmarked to sub-criticality measurements of the hexagonal fuel storage racks at the United States Geological Survey TRIGA MARK I reactor in Denver. These racks, which hold up to 19 fuel elements each, are arranged at 0.61m (2 feet) spacings around the outer edge of the reactor. A 3-dimensional model was created of the racks using MCNP5, and the model was verified experimentally by comparison to measured subcritical multiplication data collected in an approach to critical loading of two of the racks. The validated model was then used to show that in the extreme condition where the entire circumference of the pool was lined with racks loaded with used fuel the storage array is subcritical with a k value of about 0.71; well below the regulatory limit of 0.8. A model was also constructed of the rectangular 2×10 fuel storage array used in many other TRIGA reactors to validate the technique against the original TRIGA licensing sub-critical analysis performed in 1966. The fuel used in this study was standard 20% enriched (LEU) aluminum or stainless steel clad TRIGA fuel. Copyright © 2016. Published by Elsevier Ltd.

  13. Calculation of fundamental parameters for the dynamical study of TRIGA-3-Salazar reactor (Mixed reactor core)

    International Nuclear Information System (INIS)

    Viais J, J.

    1994-01-01

    Kinetic parameters for dynamic study of two different configurations, 8 and 9, both with standard fuel, 20% enrichment and Flip (Fuel Life Improvement Program with 70% enrichment) fuel, for TRIGA Mark-III reactor from Mexico Nuclear Center, are obtained. A calculation method using both WIMS-D4 and DTF-IV and DAC1 was established, to decide which of those two configurations has the best safety and operational conditions. Validation of this methodology is done by calculate those parameters for a reactor core with new standard fuel. Configuration 9 is recommended to be use. (Author)

  14. 3 MW TRIGA Research Reactor facility of BAEC and its Utilization

    Energy Technology Data Exchange (ETDEWEB)

    Molla, N.I.; Bhuiyan, S.I.; Wadud Mondal, M.A.; Ahmed, F.U.; Islam, M.N.; Hossain, S.M.; Ahmed, K.; Zulquarnain, A.; Abedin, Z. [Bangladesh Atomic Energy Commission, Atomic Energy Research Establishment, Dhaka (Bangladesh)

    1999-08-01

    The paper briefly describes the Utilisation of 3 MW TRIGA Research Reactor of BAEC for neutron beam research, neutron activation analysis are isotope production. It includes the installation of the triple axis neutron spectrometer at the radial piercing beam port and a neutron radiography set-up at the tangential beam port and their uses for material analysis and condensed matter research and material testing. Nuclear and magnetic structures of some ferrites have been studied in powder diffraction method in the double axis mode. SANS technique with double crystal diffraction known as Bonse and Hart's method has been adopted in an experiment with alumina sample. The neutron radiography set-up and its use in the detection of corrosion in alumina have been reported. Determination of arsenic concentration in drinking water from tube well via Instrumental Neutron Activation Analysis and production of radioiodine-131 by dry distillation method are presented. Our experience on the removal of N-16 decay tank because of the leakage of coolant and bringing the research reactor back to operational by-passing the decay tank have been focussed. A possible reconfiguration of the existing TRIGA core, without exceeding the safety margins, providing additional irradiation channel and upgrading the neutron flux for increased radioisotope production has been attempted. Cross section library ENDF/B-VI and JENDL3.2, code NJOY94.10, WIMSD package, 3-D code CITATION, PARET and Monte Carlo code MCNP4B2 have been employed to achieve the objective. (author)

  15. TRIGA 14 MW spent fuel shipment to USA

    International Nuclear Information System (INIS)

    Toma, C.; Barbos, D.; Preda, M.; Covaci, St.; Ciocanescu, M.

    2008-01-01

    Romania has begun to convert Pitesti TRIGA 14 MW reactor having HEU fuel in its first loading and has agreed to complete conversion of the reactor to LEU fuel by May 12, 2006. Thus it became possible to benefit of US policy as set forth in the Record of Decision (ROD) issued by the Department of Energy (DOE ) on May 13 , 1996 directed for acceptance, management and disposition of the Authorized Material which has been discharged from the foreign research reactors. Consequently, United States, DOE Idaho Operations Office and Institute for Nuclear Research at Pitesti, Romania have mutually agreed the terms and conditions set forth in a contract applicable to the receipt of the Authorized Material. Irradiated and spent nuclear fuel rods from TRIGA reactor containing uranium enriched in the United States that have met the requirements set forth in the Environmental Impact Statement and the ROD have been designated as 'Authorized Material' and transferred to Idaho National Engineering and Environmental Laboratory (INEEL)- USA during the summer of 1999 in a joint shipment. 267 TRIGA spent fuel rods loaded in a Legal Weight Truck Shipping Cask belonging to the NAC International have been transported through an overland truck route from Pitesti, Romania to Koper, Slovenia and from there it was shipped to USA. The paper has the following contents: 1.Introduction; 2.Fuel rods selection; 3.Fuel rods characterization; 4.Evaluation of TRIGA fuel in wet storage; 5.Fuel rods transfer from TRIGA pool to the transport cask; 6.Supporting documentation for transfer approval; 7. Conclusions. In conclusion one is stressed that, on site fuel evaluation process evidenced the existence of very good running and storage conditions in reactor pool during reactor operation and fuel storage. Only one fuel rod had to be packaged prior to placement in the shipping cask because of damaged cladding during negligent handling

  16. Modeling a TRIGA Mark II reactor using the Attila three-dimensional deterministic transport code

    International Nuclear Information System (INIS)

    Keller, S.T.; Palmer, T.S.; Wareing, T.A.

    2005-01-01

    A benchmark model of a TRIGA reactor constructed using materials and dimensions similar to existing TRIGA reactors was analyzed using MCNP and the recently developed deterministic transport code Attila TM . The benchmark reactor requires no MCNP modeling approximations, yet is sufficiently complex to validate the new modeling techniques. Geometric properties of the benchmark reactor are specified for use by Attila TM with CAD software. Materials are treated individually in MCNP. Materials used in Attila TM that are clad are homogenized. Attila TM uses multigroup energy discretization. Two cross section libraries were constructed for comparison. A 16 group library collapsed from the SCALE 4.4.a 238 group library provided better results than a seven group library calculated with WIMS-ANL. Values of the k-effective eigenvalue and scalar flux as a function of location and energy were calculated by the two codes. The calculated values for k-effective and spatially averaged neutron flux were found to be in good agreement. Flux distribution by space and energy also agreed well. Attila TM results could be improved with increased spatial and angular resolution and revised energy group structure. (authors)

  17. McClellan Nuclear Radiation Center (MNRC) TRIGA reactor: Four years of operations

    International Nuclear Information System (INIS)

    Heidel, C.C.; Richards, W.J.

    1994-01-01

    McClellan Air Force Base, at Sacramento, California, is headquarters for the Sacramento Air Force Logistics Center (SM-ALC). McClellan Air Force Base provides extensive inspection and maintenance capabilities for the F-111, F-1 5, and other military aircraft. Criticality of the MNRC TRIGA reactor was obtained on January 20, 1990 with 63 standard TRIGA fuel elements, three fuel-followed control rods and one air-followed control rod. Presently there are 93 fuel elements in the reactor core. The reactor can be operated at 1 MW steady state power, producing pulses up to three dollars worth of reactivity addition, and can be square waved up to 1 MW. The reactor core contains a circular grid plate and a graphite reflector assembly surrounding the core. Four tangential beam ports installed in the reflector assembly provide a thermal neutron flux to four radiography bays. The reactor tank is twenty-four (24) feet deep, seven and one-half (7.5) feet in diameter, and has a protrusion in the upper portion of the reactor tank. This protrusion is scheduled for use as a neutron thermal collimator in the future. Besides the neutron radiography capabilities, the reactor contains a pneumatic rabbit system, a central thimble, an in-core irradiation facility, and three additional cutouts that provide locations for additional irradiation facilities. The central thimble can be removed along with the B-ring locations of the upper portion of the grid plate to provide an additional and larger in-core irradiation facility. A new upper grid plate has been manufactured to expand one triangular cutout so that larger experiments can be inserted directly into the reactor core. Some operational problems experienced during the first four years of operations are the timeout of the CSC and DAC watchdogs, deterioration of the heat exchanger gaskets, and loss of thermocouples in the instrumented fuel elements. (author)

  18. Neutronic Analysis of the 3 MW TRIGA MARK II Research Reactor, Part I: Monte Carlo Simulation

    International Nuclear Information System (INIS)

    Huda, M.Q.; Chakrobortty, T.K.; Rahman, M.; Sarker, M.M.; Mahmood, M.S.

    2003-05-01

    This study deals with the neutronic analysis of the current core configuration of a 3 MW TRIGA MARK II research reactor at Atomic Energy Research Establishment (AERE), Savar, Dhaka, Bangladesh and validation of the results by benchmarking with the experimental, operational and available Final Safety Analysis Report (FSAR) values. The three-dimensional continuous-energy Monte Carlo code MCNP4C was used to develop a versatile and accurate full-core model of the TRIGA core. The model represents in detail all components of the core with literally no physical approximation. All fresh fuel and control elements as well as the vicinity of the core were precisely described. Continuous energy cross-section data from ENDF/B-VI and S(α, β) scattering functions from the ENDF/B-V library were used. The validation of the model against benchmark experimental results is presented. The MCNP predictions and the experimentally determined values are found to be in very good agreement, which indicates that the Monte Carlo model is correctly simulating the TRIGA reactor. (author)

  19. Measured and calculated effective delayed neutron fraction of the IPR-R1 Triga reactor

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Rose Mary G.P.; Dalle, Hugo M.; Campolina, Daniel A.M., E-mail: souzarm@cdtn.b, E-mail: dallehm@cdtn.b, E-mail: campolina@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    The effective delayed neutron fraction, {beta}{sub eff}, one of the most important parameter in reactor kinetics, was measured for the 100 kW IPR-R1 TRIGA Mark I research reactor, located at the Nuclear Technology Development Center - CDTN, Belo Horizonte, Brazil. The current reactor core has 63 fuel elements, containing about 8.5% and 8% by weight of uranium enriched to 20% in U{sup 235}. The core has cylindrical configuration with an annular graphite reflector. Since the first criticality of the reactor in November 1960, the core configuration and the number of fuel elements have been changed several times. At that time, the reactor power was 30 kW, there were 56 fuel elements in the core, and the {beta}{sub eff} value for the reactor recommended by General Atomic (manufacturer of TRIGA) was 790 pcm. The current {beta}{sub eff} parameter was determined from experimental methods based on inhour equation and on the control rod drops. The estimated values obtained were (774 {+-} 38) pcm and (744 {+-} 20) pcm, respectively. The {beta}{sub eff} was calculated by Monte Carlo transport code MCNP5 and it was obtained 747 pcm. The calculated and measured values are in good agreement, and the relative percentage error is -3.6% for the first case, and 0.4% for the second one. (author)

  20. 4. TRIGA owners' conference. Papers and abstracts

    International Nuclear Information System (INIS)

    1976-01-01

    The Conference covers the following aspects of TRIGA reactors operation: fuel utilization; TRIGA design and startup tests radiation release and unusual occurrences; operating experience; design of experimental facilities and instruments

  1. Research reactors in Austria - Present situation

    International Nuclear Information System (INIS)

    Boeck, H.; Musilek, A.; Villa, M.

    2005-01-01

    In the past decades Austria operated three research reactors, the 10 MW ASTRA reactor at Seibersdorf, the 250 kW TRIGA reactor at the Atominstitut and the 1 kW Argonaut reactor at the Technical University in Graz. Since the shut down of the ASTRA on July 31th, 1999 and its immediate decommissioning reactor and the shut down of the Argonaut reactor in Graz on August 31st, 2004 only one reactor remains operational for keeping nuclear competence in Austria which is the 250 kW TRIGA Mark II reactor. (author)

  2. Integrated management system implementation strategy for PUSPATI TRIGA Reactor

    International Nuclear Information System (INIS)

    Phongsakorn Prak Tom; Shaharum Ramli; Mohamad Azman Che Mat Isa; Shahirah Abdul Rahman; Mohd Zaid Mohamed; Mat Zin Mat Husin; Nurfazila Husain; Mohamad Puad Abu

    2012-01-01

    Integrated Management System (IMS) designed to fulfil the requirements integrates safety, health, environmental, security, quality and economic elements. PUSPATI TRIGA Reactor (RTP) is currently implementing the Quality Assurance Program (QAP) and looking toward implementation of IMS. This paper discussed the implementation strategy of IMS for RTP. There are nine steps of IMS implementation strategy. In implementation of IMS, Gantt chart is useful project management tool in managing the project frame work. IMS is intended as a tool to enable the continuous development of safety culture and achieve higher safety levels. (author)

  3. Feasibility study of the underwater neutron radiography facility using the University of Utah 100 kW TRIGA (UUTR) reactor

    International Nuclear Information System (INIS)

    Choe, D.; Xiao, S.; Jevremovic, T.; Yang, X.

    2010-01-01

    The University of Utah 100 kW TRIGA (UUTR) reactor provides usable neutron yields for neutron radiography. Currently, UUTR reactor has three irradiators (Central, Pneumatic, and Thermal irradiators) and one Fast neutron Irradiation Facility (FNIF). These irradiators are very small so they are not suitable for neutron radiography. UUTR has three beam ports but they are not available due to the structure of the core. All sides of the core are occupied by FNIF, Thermal Irradiator, and three ion chambers. The only available position for underwater vertical beam port is on the top of the FNIF. There are two factors necessary to fulfill to be able to realize vertical underwater beam port: noninterruption to other facilities and radiation shielding. Designing the vertical beam port as movable ensures good access to the core and pool, while still providing a good neutron radiography environment. Keeping the top of the beam port below the surface of the pool the water represents biological shield. Neutron radiographs, with a simple setup of efficient neutron converters and digital camera systems, can produce acceptable resolution with an exposure time as short as a few minutes. It is important to validate the design with calculations before constructing the beam port. The design of the beam port is modeled using the MCNP5 transport code. A minimum of 10 5 neutrons/cm 2 -sec thermal neutron flux is required for high resolution neutron radiography. Currently, the UUTRIGA is in the process of upgrading its power from 100 kW to 250 kW. Upon the completion of the upgrading, the maximum neutron flux in the core will be ∼7x10 12 neutrons/cm 2 -sec. This paper discusses a modeling and evaluation of capability for a neutron radiography facility. (author)

  4. Computational analysis of neutronic parameters of CENM TRIGA Mark II research reactor

    International Nuclear Information System (INIS)

    El Younoussi, C.; El Bakkari, B.; Boulaich, Y.; Riyach, D.; Otmani, S.; Marrhich, I.; Badri, H.; Htet, A.; Nacir, B.; El Bardouni, T.; Boukhal, H.; Zoubair, M.; Ossama, M.; Chakir, E.

    2010-01-01

    The CENM TRIGA MARK II reactor is part of the National Center for Energy, Sciences and Nuclear Techniques (CNESTEN). It's a standard design 2MW, natural-convection-cooled reactor with a graphite reflector containing 4 beam tubes and a thermal column. The reactor has several applications in different fields as industry, agriculture, medicine, training and education. In the present work a computational study has been carried out in the framework of neutronic parameters studies of the reactor. A detailed MCNP model that include all elements of the core and surrounding structures has been developed to calculate different parameters of the core (The effective multiplication factor, reactivity experiments comprising control rods worth, excess reactivity and shutdown margin). Further calculations have been carried out to calculate the neutron flux profiles at different locations of the reactor core. The cross sections used are processed from the library provided with MCNP5 and based on the ENDF/B-VII with continuous dependence in energy and special treatment of thermal neutrons in lightweight materials. (author)

  5. Safety aspects on dependability management for a TRIGA research reactor in Romania

    International Nuclear Information System (INIS)

    Vieru, Gheorghe

    2002-01-01

    Safety on the management for a nuclear research reactor involves a 'good dependability management' of the activities, such as: reliability, availability, maintainability and maintenance support. In order to evaluate the safety management aspects intended to be applied at a research reactor management, the performance dependability indicators and their impact over the availability and reactor safety have to be established. The document ISO 9000-4/IEC 300-1 'Dependability Management' (1995), describes five internationally agreed indicators of the reactor equipment dependability, each of them can be used for corrective maintenance or for preventive maintenance, such as: I 1 - equipment Maintenance Frequency; I 2 - equipment Maintenance Effort; I-3 - equipment Maintenance Downtime Factor; I 4 - equipment Maintenance Contribution to the System Function Downtime Factor; I 5 - equipment Maintenance Contribution to the reactor Capability Loss Factor. The paper presents an evaluation of those 5 mentioned indicators with referring only at the primary circuit of the INR's TRIGA research reactor and conclusion. The analyzed period was stated between 1994-1999. It is to be noted that this type of analyze is performed for the first time for a research reactor. (author)

  6. Estimation of fast neutron fluence in steel specimens type Laguna Verde in TRIGA Mark III reactor; Estimacion de la fluencia de neutrones rapidos en probetas de acero tipo Laguna Verde en el reactor Triga Mark III

    Energy Technology Data Exchange (ETDEWEB)

    Galicia A, J.; Francois L, J. L. [UNAM, Facultad de Ingenieria, Departamento de Sistemas Energeticos, Ciudad Universitaria, 04510 Ciudad de Mexico (Mexico); Aguilar H, F., E-mail: blink19871@hotmail.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2015-09-15

    The main purpose of this work is to obtain the fluence of fast neutrons recorded within four specimens of carbon steel, similar to the material having the vessels of the BWR reactors of the nuclear power plant of Laguna Verde when subjected to neutron flux in a experimental facility of the TRIGA Mark III reactor, calculating an irradiation time to age the material so accelerated. For the calculation of the neutron flux in the specimens was used the Monte Carlo code MCNP5. In an initial stage, three sheets of natural molybdenum and molybdenum trioxide (MoO{sub 3}) were incorporated into a model developed of the TRIGA reactor operating at 1 M Wth, to calculate the resulting activity by setting a certain time of irradiation. The results obtained were compared with experimentally measured activities in these same materials to validate the calculated neutron flux in the model used. Subsequently, the fast neutron flux received by the steel specimens to incorporate them in the experimental facility E-16 of the reactor core model operating at nominal maximum power in steady-state was calculated, already from these calculations the irradiation time required was obtained for values of the neutron flux in the range of 10{sup 18} n/cm{sup 2}, which is estimated for the case of Laguna Verde after 32 years of effective operation at maximum power. (Author)

  7. Analysis of Environmental Data During TRIGA 2000 Reactor Operation in PTNBR-BATAN Bandung

    International Nuclear Information System (INIS)

    Zulfakhri

    2009-01-01

    The radioactivity data of grass and soil obtained from environmental monitoring during 2000-2008 have been quantitatively and qualitatively analyzed. The data were analyzed using statistical method of the population homogeneity varians test and the average equality test, whereas qualitative analysis have been carried out by gamma spectrometry. From the data analysis, using homogeneity varians test (X 2 test) and average equality test (F test) it was obtained that X 2 calculation , F calculation > X 2 table , F table , so it can be assumed that operation of TRIGA 2000 reactor has no effect to the radioactivity of the environment. The qualitative analysis of grass and soil samples shows no visible peak of gamma ray from fission or activation products from the reactor, but the natural radionuclide such as 214 Bi, 228 Ac, 212 Bi, and 40 K were detected. It can be concluded that reactor operation have no effect to the environmental radioactivity. (author)

  8. The FLIP fuel experience at Washington State University

    International Nuclear Information System (INIS)

    Lovas, Thomas A.

    1977-01-01

    The Washington State University TRIGA-fueled modified G.E. reactor was refueled with a partial TRIGA-FLIP core in February, 1976. The final core loading consisted of 35 FLIP and 75 Standard TRIGA fuel rods and provided a core excess reactivity of $7.98. The observed performance of the reactor did not deviate significantly from the design predictions and specifications. Pulsing tests revealed a maximum power output of 1850 MW with a fuel temperature of 449 deg. C from a $2.50 pulse. Slight power fluctuations at 1 Megawatt steady-state operation and post-pulse power oscillations were observed. (author)

  9. Collimator and shielding design for boron neutron capture therapy (BNCT) facility at TRIGA MARK II reactor

    International Nuclear Information System (INIS)

    Mohd Rafi Mohd Solleh; Abdul Aziz Tajuddin; Abdul Aziz Mohamed; Eid Mahmoud Eid Abdel Munem; Mohamad Hairie Rabir; Julia Abdul Karim; Yoshiaki, Kiyanagi

    2011-01-01

    The geometry of reactor core, thermal column, collimator and shielding system for BNCT application of TRIGA MARK II Reactor were simulated with MCNP5 code. Neutron particle lethargy and dose were calculated with MCNPX code. Neutron flux in a sample located at the end of collimator after normalized to measured value (Eid Mahmoud Eid Abdel Munem, 2007) at 1 MW power was 1.06 x 10 8 n/ cm 2 / s. According to IAEA (2001) flux of 1.00 x 10 9 n/ cm 2 / s requires three hours of treatment. Few modifications were needed to get higher flux. (Author)

  10. Neutron detection of the Triga Mark III reactor, using nuclear track methodology

    Energy Technology Data Exchange (ETDEWEB)

    Espinosa, G., E-mail: espinosa@fisica.unam.mx; Golzarri, J. I. [Instituto de Física, Universidad Nacional Autónoma de México Circuito de la Investigación Científica, Ciudad Universitaria. México, DF (Mexico); Raya-Arredondo, R.; Cruz-Galindo, S. [Instituto Nacional de Investigaciones Nucleares (Mexico); Sajo-Bohus, L. [Universidad Simón Bolivar, Laboratorio de Física Nuclear, Caracas (Venezuela, Bolivarian Republic of)

    2015-07-23

    Nuclear Track Methodology (NTM), based on the neutron-proton interaction is one often employed alternative for neutron detection. In this paper we apply NTM to determine the Triga Mark III reactor operating power and neutron flux. The facility nuclear core, loaded with 85 Highly Enriched Uranium as fuel with control rods in a demineralized water pool, provide a neutron flux around 2 × 10{sup 12} n cm{sup −2} s{sup −1}, at the irradiation channel TO-2. The neutron field is measured at this channel, using Landauer{sup ®} PADC as neutron detection material, covered by 3 mm Plexiglas{sup ®} as converter. After exposure, plastic detectors were chemically etched to make observable the formed latent tracks induced by proton recoils. The track density was determined by a custom made Digital Image Analysis System. The resulting average nuclear track density shows a direct proportionality response for reactor power in the range 0.1-7 kW. We indicate several advantages of the technique including the possibility to calibrate the neutron flux density measured at low reactor power.

  11. Undergraduate reactor control experiment

    International Nuclear Information System (INIS)

    Edwards, R.M.; Power, M.A.; Bryan, M.

    1992-01-01

    A sequence of reactor and related experiments has been a central element of a senior-level laboratory course at Pennsylvania State University (Penn State) for more than 20 yr. A new experiment has been developed where the students program and operate a computer controller that manipulates the speed of a secondary control rod to regulate TRIGA reactor power. Elementary feedback control theory is introduced to explain the experiment, which emphasizes the nonlinear aspect of reactor control where power level changes are equivalent to a change in control loop gain. Digital control of nuclear reactors has become more visible at Penn State with the replacement of the original analog-based TRIGA reactor control console with a modern computer-based digital control console. Several TRIGA reactor dynamics experiments, which comprise half of the three-credit laboratory course, lead to the control experiment finale: (a) digital simulation, (b) control rod calibration, (c) reactor pulsing, (d) reactivity oscillator, and (e) reactor noise

  12. Basic research using the 250 KW research reactor triga in Ljubljana, Yugoslavia

    International Nuclear Information System (INIS)

    Dimic, V.

    1983-01-01

    The 25 KW Triga Mark II reactor of J. 'Stefan Institute' was commissioned on May 1966. During the last two years, it has been operated for about 4200 hr/year. According to experience gained with the reactor, most of the cost of reactor operation will be earned through isotope production for local hospitals and industries, performing low cost applied experiments and organizing training courses. The rest was provided through the Research Communities of the Republic of Slovenia. The reactor has been operated for 15 years without major problems and many basic research programmes have been performed. The research is being conducted in the following mainfields: solid state physics, neutron dosimetry, neutron radiography and autoradiography, reactor physics, examination of nuclear fuel using gamma scanning, irradiation of semiconducting materials and neutron activation analysis. (A.J)

  13. Development of the ageing management database of PUSPATI TRIGA reactor

    Energy Technology Data Exchange (ETDEWEB)

    Ramli, Nurhayati, E-mail: nurhayati@nm.gov.my; Tom, Phongsakorn Prak; Husain, Nurfazila; Farid, Mohd Fairus Abd; Ramli, Shaharum [Reactor Technology Centre, Malaysian Nuclear Agency, MOSTI, Bangi, 43000 Kajang, Selangor (Malaysia); Maskin, Mazleha [Science Program, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Selangor (Malaysia); Adnan, Amirul Syazwan; Abidin, Nurul Husna Zainal [Faculty of Petroleum and Renewable Energy Engineering, Universiti Teknologi Malaysia (Malaysia)

    2016-01-22

    Since its first criticality in 1982, PUSPATI TRIGA Reactor (RTP) has been operated for more than 30 years. As RTP become older, ageing problems have been seen to be the prominent issues. In addressing the ageing issues, an Ageing Management (AgeM) database for managing related ageing matters was systematically developed. This paper presents the development of AgeM database taking into account all RTP major Systems, Structures and Components (SSCs) and ageing mechanism of these SSCs through the system surveillance program.

  14. Biological Tests for Boron Neutron Capture Therapy Research at the TRIGA Mark II Reactor in Pavia

    Energy Technology Data Exchange (ETDEWEB)

    Protti, N.; Ballarini, F.; Bortolussi, S.; De Bari, A.; Stella, S.; Altieri, S. [Department of Nuclear and Theoretical Physics, University of Pavia, Pavia (Italy); Nuclear Physics National Institute (INFN), Pavia (Italy); Bruschi, P. [Department of Nuclear and Theoretical Physics, University of Pavia, Pavia (Italy); Bakeine, J.G.; Cansolino, L.; Clerici, A.M. [Laboratory of Experimental Surgery, Department of Surgery, University of Pavia, Pavia (Italy)

    2011-07-01

    The thermal column of the TRIGA Mark II reactor of the Pavia University is used as an irradiation facility to perform biological tests and irradiations of living systems for Boron Neutron Capture Therapy (BNCT) research. The suitability of the facility has been ensured by studying the neutron flux and the photon background in the irradiation chamber inside the thermal column. This characterization has been realized both by flux and dose measurements as well as by Monte Carlo simulations. The routine irradiations concern in vitro cells cultures and different tumor animal models to test the efficacy of the BNCT treatment. Some results about these experiments will be described. (author)

  15. Experimental study of the temperature distribution in the TRIGA IPR-R1 Brazilian research reactor; Investigacao experimental da distribuicao de temperaturas no reator nuclear de pesquisa TRIGA IPR-R1

    Energy Technology Data Exchange (ETDEWEB)

    Mesquita, Amir Zacarias

    2005-07-01

    The TRIGA-IPR-R1 Research Nuclear Reactor has completed 44 years in operation in November 2004. Its initial nominal thermal power was 30 kW. In 1979 its power was increased to 100 kW by adding new fuel elements to the reactor. Recently some more fuel elements were added to the core increasing the power to 250 kW. The TRIGA-IPR-R1 is a pool type reactor with a natural circulation core cooling system. Although the large number of experiments had been carried out with this reactor, mainly on neutron activation analysis, there is not many data on its thermal-hydraulics processes, whether experimental or theoretical. So a number of experiments were carried out with the measurement of the temperature inside the fuel element, in the reactor core and along the reactor pool. During these experiments the reactor was set in many different power levels. These experiments are part of the CDTN/CNEN research program, and have the main objective of commissioning the TRIGA-IPR-R1 reactor for routine operation at 250 kW. This work presents the experimental and theoretical analyses to determine the temperature distribution in the reactor. A methodology for the calibration and monitoring the reactor thermal power was also developed. This methodology allowed adding others power measuring channels to the reactor by using thermal processes. The fuel thermal conductivity and the heat transfer coefficient from the cladding to the coolant were also experimentally valued. lt was also presented a correlation for the gap conductance between the fuel and the cladding. The experimental results were compared with theoretical calculations and with data obtained from technical literature. A data acquisition and processing system and a software were developed to help the investigation. This system allows on line monitoring and registration of the main reactor operational parameters. The experiments have given better comprehension of the reactor thermal-fluid dynamics and helped to develop numerical

  16. Estimation of fast neutron fluence in steel specimens type Laguna Verde in TRIGA Mark III reactor

    International Nuclear Information System (INIS)

    Galicia A, J.; Francois L, J. L.; Aguilar H, F.

    2015-09-01

    The main purpose of this work is to obtain the fluence of fast neutrons recorded within four specimens of carbon steel, similar to the material having the vessels of the BWR reactors of the nuclear power plant of Laguna Verde when subjected to neutron flux in a experimental facility of the TRIGA Mark III reactor, calculating an irradiation time to age the material so accelerated. For the calculation of the neutron flux in the specimens was used the Monte Carlo code MCNP5. In an initial stage, three sheets of natural molybdenum and molybdenum trioxide (MoO 3 ) were incorporated into a model developed of the TRIGA reactor operating at 1 M Wth, to calculate the resulting activity by setting a certain time of irradiation. The results obtained were compared with experimentally measured activities in these same materials to validate the calculated neutron flux in the model used. Subsequently, the fast neutron flux received by the steel specimens to incorporate them in the experimental facility E-16 of the reactor core model operating at nominal maximum power in steady-state was calculated, already from these calculations the irradiation time required was obtained for values of the neutron flux in the range of 10 18 n/cm 2 , which is estimated for the case of Laguna Verde after 32 years of effective operation at maximum power. (Author)

  17. MOTHER MK II: An advanced direct cycle high temperature gas reactor

    International Nuclear Information System (INIS)

    Hart, R.S.; Kendall, J.M.; Marsden, B.J.

    2003-01-01

    The MOTHER (MOdular Thermal HElium Reactor) power plant concepts employ high temperature gas reactors utilizing TRISO fuel, graphite moderator, and helium coolant, in combination with a direct Brayton cycle for electricity generation. The helium coolant from the reactor vessel passes through a Power Conversion Unit (PCU), which includes a turbine-generator, recuperator, precooler, intercooler and turbine-compressors, before being returned to the reactor vessel. The PCU substitutes for the reactor coolant system pumps and steam generators and most of the Balance Of Plant (BOP), including the steam turbines and condensers, employed by conventional nuclear power plants utilizing water cooled reactors. This provides a compact, efficient, and relatively simple plant configuration. The MOTHER MK I conceptual design, completed in the 1987 - 1989 time frame, was developed to economically meet the energy demands for extracting and processing heavy oil from the tar sands of western Canada. However, considerable effort was made to maximize the market potential beyond this application. Consistent with the remote and very high labour rate environment in the tar sands region, simplification of maintenance procedures and facilitation of 'change-out' in lieu of in situ repair was a design focus. MOTHER MK I had a thermal output of 288 MW and produced 120 MW electrical when operated in the electricity only production mode. An annular Prismatic reactor core was utilized, largely to minimize day-to-day operations activities. Key features of the power conversion system included two Power Conversion Units (144 MW th each), the horizontal orientation of all rotating machinery and major heat exchangers axes, high speed rotating machinery (17,030 rpm for the turbine-compressors and 10,200 rpm for the power turbine-generator), gas (helium) bearings for all rotating machinery, and solid state frequency conversion from 170 cps (at full power) to the grid frequency. Recognizing that the on

  18. The development of quality assurance program in Reactor TRIGA PUSPATI (RTP)

    International Nuclear Information System (INIS)

    Rosli Darmawan; Mohd Rizal Mamat; Mohamad Zaid Mohamad; Mohd Ridzuan Abdul Mutalib

    2007-01-01

    One of the trivial issues in the operation of Nuclear Reactor is the safety of the system. Worldwide publicity on a few nuclear accidents as well as the notorious Hiroshima and Nagasaki bombing has always bring about general public fear on anything related to nuclear. IAEA has always emphasized on the assurance of nuclear safety for all nuclear installations and activities. According to the IAEA safety guides, all research reactors are required to implement quality assurance programs to ensure the conduct of operations are in accordance with the safety standards required. This paper discusses the activities carried out toward the establishment of Quality Assurance Program for Reaktor TRIGA PUSPATI (RTP). (Author)

  19. Feasibility study of application of Prompt Gamma Neutron Activation Analysis (PGNAA) method in TRIGA IPR-R1 reactor

    International Nuclear Information System (INIS)

    Guerra, Bruno Teixeira

    2016-01-01

    The TRIGA Mark I IPR-R1 research reactor is located at Nuclear Technology Development Centre (CDTN), Brazilian Commission for Nuclear Energy (CNEN), in Belo Horizonte, Brazil. The reactor operates at 100 kW but the core configuration allows the increasing of the power up to 250 kW. It has been applied research, training and radioisotopes production. The establishment of the Prompt Gamma Neutron Activation Analysis (PGNAA) method at the TRIGA IPR-R1 reactor will significantly increase the types of matrices analysed as well as the number of chemical elements. Additionally it will complement the neutron activation analysis. This work presents a proposed design of a PGNAA facility to be installed at the TRIGA IPR-R1. The proposed design is based on a tube as a neutron guide from the reactor core, inside the reactor pool, 6 m below the room’s level where shall be located the rack containing the set sample/detector/shielding. Thus, the aim of this study is to verify the feasibility to establish the PGNAA method in IPR-R1 through theoretical study applying the Monte Carlo code. The feasibility of establishing the PGAA method at the IPR-R1 installations was evaluated through of the calculations of neutron flux, radioactive capture reaction rates and detection limits for some isotopes. According to the obtained results, it can be concluded that is possible to establish the PGAA method at the IPR-R1 reactor, even with some restrictions in its theoretical design calculated by MCNP. (author)

  20. Production and use of {sup 18}F by TRIGA nuclear reactor: a first report

    Energy Technology Data Exchange (ETDEWEB)

    Burgio, N.; Ciavola, C.; Festinesi, A.; Capannesi, G. [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dipt. Innovazione

    1999-02-01

    The irradiation and radiochemical facilities at public research centre can contribute to the start up of the regional PET centre. In particular, the TRIGA reactor of Casaccia Research Centre could produce a sufficient amount of {sup 18}F to start up a PET centre and successively integrated the cyclotron production. This report establishes, in the light of the preliminary experimental works, a guideline to the reactor`s production and extraction of {sup 18}F in a convenient form for the synthesis of the most representative PET radiopharmaceutical: {sup 18}F-FDG. [Italiano] Le facilities di irraggiamento e i laboratori Radiochimici dei Centri Statali di Ricerca possono contribuire allo sviluppo di centri regionali PET (Tomografia ed Emissione Positronica). In particolare, il reattore TRIGA del Centro Ricerca Casaccia potrebbe produrre un quantitativo di {sup 18}F sufficiente alle attivita` formative propedeutiche al centro PET che, successivamente sarebbe in grado di avviare una propria produzione da ciclotrone. Questo rapporto stabilisce le linee guida sperimentali per la produzione del {sup 18}F da reattore nucleare e la sua successiva estrazione in una forma conveniente per la sintesi del piu` rappresentativo dei radiofarmaci PET: il {sup 18}F-FDG.

  1. Berkeley Nuclear Laboratories Reactor Physics Mk. III Experimental Programme. Description of facility and programme for 1971

    Energy Technology Data Exchange (ETDEWEB)

    Nunn, R M; Waterson, R H; Young, J D

    1971-01-15

    Reactor physics experiments have been carried out at Berkeley Nuclear Laboratories during the past few years in support of the Civil Advanced Gas-Cooled Reactors (Mk. II) the Generating Board is building. These experiments are part of an overall programme whose objective is to assess the accuracy of the calculational methods used in the design and operation of these reactors. This report provides a description of the facility for the Mk. III experimental programme and the planned programme for 1971.

  2. Experimental study of the IPR-R1 TRIGA reactor power channels responses

    International Nuclear Information System (INIS)

    Mesquita, Henrique F.A.; Ferreira, Andrea V.

    2015-01-01

    The IPR-R1 nuclear reactor installed at Centro de Desenvolvimento da Tecnologia Nuclear CDTN/CNEN, Belo Horizonte, Brazil, is a Mark I TRIGA reactor (Training, Research, Isotopes, General Atomics) and became operational on November of 1960. The reactor has four irradiation devices: a rotary specimen rack with 40 irradiation channels, the central tube, and two pneumatic transfer tubes. The nuclear reactor is operated in a power range between zero and 100 kW. The instrumentation for IPR-R1 operation is mainly composed of four neutronic channels for power measurements. The aim of this work is to investigate the responses of neutronic channels of IPR-R1, Linear, Log N and Percent Power channels, and to check their linearity. Gold foils were activated at low powers (0.125-1.000 kW), and cobalt foils were activated at high powers (10-100kW). For each sample irradiated at rotary specimen rack, another one was irradiated at the same time at the pneumatic transfer tube-2. The obtained results allowed evaluating the linearity of the neutronic channels responses. (author)

  3. Study of Physical Protection System at PUSPATI TRIGA Reactor (RTP)

    International Nuclear Information System (INIS)

    Ligam, A.S.; Ina, I.; Zarina Masood

    2016-01-01

    Physical protection program at PUSPATI TRIGA Reactor (RTP) which is located at Nuklear Malaysia, Bangi Complex has been strengthened and upgraded from time to time to accommodate current situation needs. However, there is always room for improvement. Hence, study have been made to look deeper into physical protection components such as delay systems, external sensors, PPS intruder alarm sensors, use of video system, personnel security or insider threats, access control operation system operation rules and security culture that may need to take into consideration. (author)

  4. Treatment for dismantled radioactive solid waste from the TRIGA Mark-2 and 3

    International Nuclear Information System (INIS)

    Park, Seung Kook; Jung, Kyung Hwan

    1999-06-01

    Radioactive wastes are generally classified into 3 type depending on their physical property: liquid, solid and gaseous type. State-of -the art concerning liquid waste treatment has already been published; KAERI/TR-1315/99. Solid wastes classification package and treatment method will be studied to effectively manage them during the practical decommissioning work. All of the spent fuel produced during the operation of the TRIGA Mark-2 and 3 have been transported to the US last year, 1998, according to the spent fuel management strategy set-up by the US government for the non-proliferation of nuclear energy. Solid wastes are mainly all equipment existing inside of the reactors, activated concrete among the bio-shielded concrete, pipes, pimps, resin filter and it's housings, heat-exchangers, liquid waste storage tanks, to radioactive waste storage treatment facilities and so on. Solid wastes are generally low-level. They are classified according to the national regulation and nuclear law and IAEA Safety Standard Series ST-1(1996). Medium level radioactive wastes from reactor structures, mainly stainless steel component from the Rotary Specimen Rack(RSR) will be properly dismantled and stored in a shield container such as TIF(TRIGA Irradiated Fuel) container. While, low-level solid waste will be treated and packed in a ISO container(4m 3 ISO container for example) according to the IAEA recommendation. And combustible solid waste such as cloths, gloves, paper etc. will be packed in a 200 liters drum. This state-of-the art shows a general feature of the solid radioactive waste management which will be produced during the decommissioning of the TRIGA Mark-2 and 3 research reactors. (author). 17 refs., 17 tabs., 2 figs

  5. The AFRRI TRIGA reactor: a summary of applications in mouse studies - 345

    International Nuclear Information System (INIS)

    Ledney, G.D.; Elliott, T.B.

    2010-01-01

    The AFRRI TRIGA reactor was used to simulate nuclear weapon mixed-field radiation injuries with and without additional tissue trauma. The severity of reactor-produced mixed-field radiations over that of γ-photon irradiation was evaluated in mice. Lethal doses (LDs) to 50% of groups of mice were determined for marrow cell (LD 50/30 , the dose required to kill 50% of the subjects within 30 days) and intestinal cell (LD 50/6 , the dose required to kill 50% of the subjects within 6 days) injury. As neutron (n) proportions in the total (t) radiation dose (D n /D t ) increased LD values decreased. Relative biological effectiveness (RBE) values for reactor-generated D n /D t used 60 Co γ photons and 250-kVp x-rays as reference standards. RBEs for irradiated mice increased as D n /D t increased and was further increased by wound trauma. Compared to γ-photon irradiation, mixed-field irradiation delayed wound closure times 25% to 50%. WR-151327 (200 mg/kg), a radioprotective chemical, injected i.p. into mice prior to either radiation quality alone or into combined injured mice increased 30-day survival and reduced susceptibility to challenge with Klebsiella pneumoniae. Protection against irradiation and resistance to bacterial challenge afforded by the WR compound was greater for γ-photon irradiation than for mixed-field irradiation. The TRIGA reactor can be used to simulate nuclear radiation-induced situations that include traumas or infections. Countermeasures for increasing survival after mixed-field irradiation may be more difficult than for γ-photon irradiated casualties. (authors)

  6. Damage analysis of TRIGA MARK II Bandung reactor tank material structure

    International Nuclear Information System (INIS)

    Soedardjo; Sumijanto

    2000-01-01

    Damage of Triga Mark II Bandung reactor tank material structure has been analyzed. The analysis carried out was based on ultrasonic inspection result in 1996 and the monthly reports of reactor operation by random data during 1988 up to 1995. Ultrasonic test data had shown that thinning processes on south and west region of reactor out side wall at upper part of water level had happened. Reactor operation data had shown the demineralized water should be added monthly to the reactor and bulk shielding water tank. Both reactor and bulk shielding tank are shielded by concrete of Portland type I cement consisting of CaO content about 58-68 %. The analysis result shows that the reaction between CaO and seepage water from bulk shielding wall had taken place and consequently the reactor out sidewall surroundings became alkaline. Based on Pourbaix diagram, the aluminum reactor tank made of aluminum alloy 6061 T6 would be corroded easily at pH equal an greater than 8.6. The passive layer AI 2 O 3 aluminum metal surface would be broken due to water reaction taken place continuously at high pH and produces hydrogen gas. The light hydrogen gas would expand the concrete cement and its expanding power would open the passive layer of aluminum metal upper tank. The water sea pages from adding water into reactor tank could indicate the upper water level tank corrosion is worse than the lower water level tank. (author)

  7. Visual examination program of the TRIGA Mark II reactor Vienna with the nuclear underwater telescope

    International Nuclear Information System (INIS)

    Boeck, H.; Hammer, J.; Varga, K.

    1985-12-01

    The visual inspection programm carried out during a three month shut-period at the TRIGA Mark II reactor Vienna is described. Optical inspection of all welds inside the reactor tank was carried out with an underwater telescope developed by the Central Research Institute of Physics, Budapest, Hungary. It is shown that even after 23 years of reactor operation all tank internals were found to be in good condition and minor defects can be easily repaired by remote handling tools. (Author)

  8. Proceedings of the 4. World TRIGA Users Conference

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-10-29

    This document gathers 30 presentations given at the 2008 Conference of the World TRIGA reactor Users. Most presentations are in the form of slides only, and few ones have an additional summary or are presented as an article only. All aspects of TRIGA-type reactors are approached, from upgrading to decommissioning, from radiotherapy to isotope production, from research program management to training, etc.

  9. Proceedings of the 4. World TRIGA Users Conference

    International Nuclear Information System (INIS)

    2008-01-01

    This document gathers 30 presentations given at the 2008 Conference of the World TRIGA reactor Users. Most presentations are in the form of slides only, and few ones have an additional summary or are presented as an article only. All aspects of TRIGA-type reactors are approached, from upgrading to decommissioning, from radiotherapy to isotope production, from research program management to training, etc

  10. U.S. Domestic Reactor Conversion Programs

    International Nuclear Information System (INIS)

    Woolstenhulme, Eric

    2008-01-01

    The Conversion Projects Include: the revision of the facilities safety basis documents and supporting analysis, the fabrication of new LEU fuel, the change-out of the reactor core, and the removal of the used HEU fuel (by INL University Fuels Program or DOE-NE). The major entities involved are: the U.S. Nuclear Regulatory Commission, the University reactor department, the fuel and hardware fabricators, the Spent fuel receipt facilities, the Spent fuel shipping services, and the U.S. Department of Energy and their subcontractors. Three major Reactor Conversion Program milestones have been accomplished since 2006: the conversion of the TRIGA reactor at Texas A and M University Nuclear Science Center, the conversion of the University of Florida Training Reactor, and the conversion of the Purdue University Reactor. Four Reactor Conversion Program milestones yet to be accomplished in 2008 and 2009: the Washington State University Nuclear Radiation Center reactor, the Oregon State University TRIGA Reactor, the University of Wisconsin Nuclear Reactor, and the Neutron Radiography Reactor Facility. NNSA is committed to doing things cheaper, better, smarter, safer through a 'Lessons Learned' process. The conversion team assessed each major activity grouping: Project Initiation, Conversion Proposal Development, Fuel Fabrication and Hardware, Core Conversion, and Spent Nuclear Fuel Removal. Issues were identified and recommendations were given

  11. Proceedings of 2. Yugoslav symposium on reactor physics, Part 2, Herceg Novi (Yugoslavia), 27-29 Sep 1966

    International Nuclear Information System (INIS)

    1966-01-01

    This Volume 2 of the Proceedings of 2. Yugoslav symposium on reactor physics includes eight papers dealing with the following topics: method for measuring high anti reactivities of a reactor system; integration method for thermal reaction rate calculation; Determination of initial core configuration for BHWR-200 MWe; safety shutdowns and failures of the RA reactor equipment; determining the reactivity of absorption rods; measurements of thermal and fast neutron fluxes at the TRIGA reactor and other measurements during operation of the TRIGA reactor; mathematical modelling of the reactor safety; review of problems and methods for radiation risk assessment in the environment of a nuclear power plant

  12. Evaluation of WIMS-D/4 nuclear data library used on TRIGA reactor calculation

    International Nuclear Information System (INIS)

    Chen Wei; Xie Zhongsheng; Jiang Xinbiao; Chen Da

    1997-01-01

    The 69 groups constants of H in ZrH, 166 Er and 167 Er generated by NJOY and GASKET codes are inserted into WIMS nuclear data library WIMS-CNDC and WIMS-NINT libraries used on RTIGA reactor calculation are obtained. In order to check WIMS-CNDC and WIMS-NINT libraries, the scattering cross-section is compared with that in WIMS-IJS library. The group constant, K ∞ and temperature coefficient are calculated by using WIMS-CNDC, WIMS-NINT and WIMS-IJS. The results show the both libraries are suitable for calculation of TRIGA reactor

  13. Characterization of the TRIGA Mark III reactor for k0-neutron activation analysis

    International Nuclear Information System (INIS)

    Diaz R, O.; Herrera P, E.; Lopez R, M.C.

    1997-01-01

    The non-ideality of the epithermal neutron flux distribution in a a reactor site parameter (α), the thermal-to-epithermal neutron ratio (f), the irradiation channel neutron temperature (T n ) and the k 0 -factors for more than 20 isotopes were determined in the 3 typical irradiation positions of the TRIGA Mark III reactor of the National Nuclear Research Institute, Salazar, Mexico, using different experimental methods with conventional and non-conventional monitors. This characterization is used in the k 0 -method of NAA, recently introduced at the Institute. (author). 21 refs., 3 figs., 5 tabs

  14. Transient behavior during reactivity insertion in the Moroccan TRIGA Mark II reactor using the PARET/ANL code

    International Nuclear Information System (INIS)

    Boulaich, Y.; Nacir, B.; El Bardouni, T.; Boukhal, H.; Chakir, E.; El Bakkari, B.; El Younoussi, C.

    2015-01-01

    Highlights: • PARET model for the Moroccan TRIGA MARK II reactor has been developed. • Transient behavior under reactivity insertion has been studied based on PARET code. • Power factors required by PARET code have been calculated by using MCNP5 code. • The dependence on time of the main thermal-hydraulic parameters was calculated. • Results are largely far to compromise the thermal design limits. - Abstract: A three dimensional model for the Moroccan 2 MW TRIGA MARK II reactor has been developed for thermal-hydraulic and safety analysis by using the PARET/ANL and MCNP5 codes. This reactor is located at the nuclear studies center of Mâamora (CENM), Morocco. The model has been validated through temperature measurements inside two instrumented fuel elements located near the center of the core, at various power levels, and also through the power and fuel temperature evolution after the reactor shutdown (SCRAM). The axial distributions of power factors required by the PARET code have been calculated in each fuel element rod by using MCNP5 code. Based on this thermal-hydraulic model, a safety analysis under the reactivity insertion phenomenon has been carried out and the dependence on time of the main thermal-hydraulic parameters was calculated. Results were compared to the thermal design limits imposed to maintain the integrity of the clad

  15. The Boron Neutron Capture Therapy (BNCT) Project at the TRIGA Reactor in Mainz, Germany

    Energy Technology Data Exchange (ETDEWEB)

    Hampel, G.; Grunewald, C.; Schutz, C.; Schmitz, T.; Kratz, J.V. [Nuclear Chemistry, University of Mainz, D-55099 Mainz (Germany); Brochhausen, C.; Kirkpatrick, J. [Department of Pathology, University of Mainz, D-55099 Mainz (Germany); Bortulussi, S.; Altieri, S. [Department of Nuclear and Theoretical Physics University of Pavia, Pavia (Italy); National Institute of Nuclear Physics (INFN) Pavia Section, Pavia (Italy); Kudejova, P. [Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II), Technische Universitaet Muenchen, D-85748 Garching (Germany); Appelman, K.; Moss, R. [Joint Research Centre (JRC) of the European Commission, NL-1755 ZG Petten (Netherlands); Bassler, N. [University of Aarhus, Norde Ringade, DK-8000, Aarhus C (Denmark); Blaickner, M.; Ziegner, M. [Molecular Medicine, Health and Environment Department, AIT Austrian Institute of Technology GmbH (Austria); Sharpe, P.; Palmans, H. [National Physical Laboratory, Teddington TW11 0LW, Middlesex (United Kingdom); Otto, G. [Department of Hepatobiliary, Pancreatic and Transplantation Surgery, University of Mainz, D-55099 Mainz (Germany)

    2011-07-01

    The thermal column of the TRIGA reactor in Mainz is being used very effectively for medical and biological applications. The BNCT (boron neutron capture therapy) project at the University of Mainz is focussed on the treatment of liver tumours, similar to the work performed in Pavia (Italy) a few years ago, where patients with liver metastases were treated by combining BNCT with auto-transplantation of the organ. Here, in Mainz, a preclinical trial has been started on patients suffering from liver metastases of colorectal carcinoma. In vitro experiments and the first animal tests have also been initiated to investigate radiobiological effects of radiation generated during BNCT. For both experiments and the treatment, a reliable dosimetry system is necessary. From work elsewhere, the use of alanine detectors appears to be an appropriate dosimetry technique. (author)

  16. Moroccan TRIGA nuclear reactor, an important tool for the development of research, education and training

    International Nuclear Information System (INIS)

    Caoui, A.

    2011-01-01

    Full text: The construction of the Nuclear Research Center of Maamora (NRCM) will enable to the National Center for Nuclear Energy, Sciences and Techniques (CNESTEN) to fulfill its missions for promotion of nuclear techniques in socioeconomic fields, act as technical support for the authorities, and contribute to the introduction of nuclear power for electricity generation considered in the new energy strategy as alternative option for the period 2020-2030. The CNESTEN has commisioned its nuclear research reactor Triga Mark II of 2000 KW on 2007 for wich the operating authorization was delivered on 2009. This research reactor is the keystone structure of the NRCM, its existing and planed utilization include: production of radioisotopes for medical use, neutron activation analysis, non-destructive examination techniques, neutron scattering, reactor physics research and training. In term of human ressources development, CNESTEN is more focusing on education and training for wich an international training Center is under development. The TRIGA research reactor will be an important component of this center. In order to promote the utilization of the reserch reactor in socio-economical sectors at national level, CNESTEN organizea meetings, schools and conferences around each of the reactor applications, and offers the opportunity to researchers, students, socio-economic operators to know more about reactor utilization within scientific visits, courses and training programs. At the international level, CNESTEN strengthens its international partenership. The regional and international cooperation with IAEA, AFRA and bilateral parteners (USA, France), constitutes the platform for capacity building in different areas of CNESTEN RIGA research reactor utilization

  17. Mechanism design for the control rods conduction of TRIGA Mark III reactor in the NINR; Diseno del mecanismo para la conduccion de las barras de control del reactor Triga Mark III del ININ.

    Energy Technology Data Exchange (ETDEWEB)

    Franco C, A

    1997-12-01

    This work presents in the first chapter a general studio about the reactor and the importance of control rods in the reactor , the mechaniucal design attending to requisitions that are imposed for conditions of operation of the reactor are present in the second chapter, the narrow relation that exists with the new control console and the mechanism is developed in the thired chapter, this relation from a point of view of an assembly of components is presents in fourth chapter, finally reaches and perspectives of mechanism forming part of project of the automation of reactor TRIGA MARK III, are present in the fifth chapter. (Author).

  18. New burnup calculation of TRIGA IPR-R1 reactor

    International Nuclear Information System (INIS)

    Meireles, Sincler P. de; Campolina, Daniel de A.M.; Santos, Andre A. Campagnole dos; Menezes, Maria A.B.C.; Mesquita, Amir Z.

    2015-01-01

    The IPR-R1 TRIGA Mark I research reactor, located at the Nuclear Technology Development Center - CDTN, Belo Horizonte, Brazil, operates since 1960.The reactor is operating for more than fifty years and has a long history of operation. Determining the current composition of the fuel is very important to calculate various parameters. The reactor burnup calculation has been performed before, however, new techniques, methods, software and increase of the processing capacity of the new computers motivates new investigations to be performed. This work presents the evolution of effective multiplication constant and the results of burnup. This new model has a more detailed geometry with the introduction of the new devices, like the control rods and the samarium discs. This increase of materials in the simulation in burnup calculation was very important for results. For these series of simulations a more recently cross section library, ENDF/B-VII, was used. To perform the calculations two Monte Carlo particle transport code were used: Serpent and MCNPX. The results obtained from two codes are presented and compared with previous studies in the literature. (author)

  19. Personnel, Area And Environmental Surveillance Practices At The PUSPATI TRIGA Reactor

    International Nuclear Information System (INIS)

    Ligam, A.S.; Zarina Masood; Mohammad Suhaimi Kassim; Ismail Sulaiman; Mohd Fazli Zakaria; Ahmad Nabil Abdul Rahim

    2013-01-01

    Personnel, area and environmental surveillance at research reactors are important to ensure that the worker, public and environment do not receive radiation doses exceeding the prescribed national limits. A surveillance programme has been in place ever since the PUSPATI TRIGA Reactor (RTP) first started its operation in 1982. The results of the surveillance have to be reported to the national regulatory body as well as the International Atomic Energy Agency. This paper will discuss the findings and improvements of the surveillance programme over the past few years. It can be concluded that workers, public and the environment does not receive doses in excess of the prescribed limits due to the operation of the RTP.(author)

  20. Operation and maintenance of the 250 kW TRIGA Mark II reactor at the J. Stefan Institute

    International Nuclear Information System (INIS)

    Dimic, V.

    1982-01-01

    Over the last two years the TRIGA Mark II reactor in Ljubljana has been operated at an energy release of about 2250 MWh or about 4200 hours per year. In this period, about 2000 samples were irradiated. Since the last TRIGA Owners' Conference there has been an increase in all operational data because of a very extensive programme of irradiation of molybdenum for the everyday production of technetium-99 m by a solvent extraction method. Because of its age and absolencence replacement of the console electronics was considered some time ago. Therefore, partly new instrumentation was installed this year. A new console is under construction. Furthermore, a new core configuration was established after 7 fresh FLIP fuel elements were delivered by GA. At this time it was noticed that 2 dummy elements are stuck in the upper grid plate. They will be exchanged during the regular maintenance work in August this year. During the last two years the reactor has been operated without any longer shut-down due to technical difficulties. (author)

  1. 5. TRIGA owners' conference. Papers and abstracts

    International Nuclear Information System (INIS)

    1977-01-01

    The main topics of the Conference are: research reactor licensing and regulation; standards and public relations programs; operating problems and operating programs of research reactors; security requirements for TRIGA reactors

  2. In-service inspection and maintenance schedule for a typical TRIGA Mark-II reactor

    International Nuclear Information System (INIS)

    Boeck, H.

    1996-05-01

    This report lists all the systems and components of the TRIGA reactor Vienna which are inspected and maintained in regular intervals. These intervals are categorized in monthly, quarterly, semi-annual and annual inspections. Further the type of inspection and the responsibility for the inspection is shown. For each component specific inspection sheets have been developed, some examples are given in the annex. (author)

  3. 3. world TRIGA users conference. Papers and abstracts

    International Nuclear Information System (INIS)

    2006-01-01

    The Conference is focused on TRIGA reactors operation and applications. The main topics are: use of the reactor as a research tool; inspection of spent fuel elements; integrity of fuel rods cladding checks; evaluation of corrosion of aluminum-base fuel cladding materials; Pitting behavior of Aluminum alloys; Monte Carlo simulation of TRIGA: reactivity worth, burnup, flux and power; irradiation facilities; thermal hydraulics analyses etc

  4. Effects of Cooling Fluid Flow Rate on the Critical Heat Flux and Flow Stability in the Plate Fuel Type 2 MW TRIGA Reactor

    OpenAIRE

    H. P. Rahardjo; V. I. Sri Wardhani

    2017-01-01

    The conversion program of the 2 MW TRIGA reactor in Bandung consisted of the replacement of cylindrical fuel (produced by General Atomic) with plate fuel (produced by BATAN). The replacement led into the change of core cooling process from upward natural convection type to downward forced convection type, and resulted in different thermohydraulic safety criteria, such as critical heat flux (CHF) limit, boiling limit, and cooling fluid flow stability. In this paper, a thermohydraulic safety an...

  5. Design and safety considerations for the 10 MW(t) multipurpose TRIGA reactor in Thailand

    International Nuclear Information System (INIS)

    Razvi, J.; Bolin, J.M.; Saurwein, J.J.; Whittemore, W.L.; Proongmuang, S.

    1999-01-01

    General Atomics (GA) is constructing the Ongkharak Nuclear Research Center (ONRC) near Bangkok, Thailand for the Office of Atomic Energy for Peace. The ONRC complex includes the following: A multipurpose 10 MW(t) research reactor; An Isotope Production Facility; Centralized Radioactive Waste Processing and Storage Facilities. The Center is being built 60-km northeast of Bangkok, with a 10 MW(t) TRIGA type research reactor as the centerpiece. Facilities are included for neutron transmutation doping of silicon, neutron capture therapy neutron beam research and for production of a variety of radioisotopes. The facility will also be utilized for applied research and technology development as well as training in reactor operations, conduct of experiments and in reactor physics. The multipurpose, pool-type reactor will be fueled with high-density (45 wt%), low-enriched (19.7 wt%) uranium-erbium-zirconium-hydride (UErZrH) fuel rods, cooled and moderated by light water, and reflected by beryllium and heavy water. The general arrangement of the reactor and auxiliary pool structure allows irradiated targets to be transferred entirely under water from their irradiation locations to the hot cell, then pneumatically transferred to the adjacent Isotope Production Facility for processing. The core configuration includes 4 x 4 array standard TRIGA fuel clusters, modified clusters to serve as fast-neutron irradiation facilities, control rods and an in-core Ir-192 production facility. The active core is reflected on two sides by beryllium and on the other two sides by D 2 O. Additional irradiation facilities are also located in the beryllium reflector blocks and the D 2 O reflector blanket. The fuel provides the fundamental safety feature of the ONRC reactor, and as a result of all the well established accident-mitigating characteristics of the UErZrH fuel itself (large prompt negative temperature coefficient of reactivity, fission product retention and chemical stability), a

  6. Cooling Performance Analysis of ThePrimary Cooling System ReactorTRIGA-2000Bandung

    Science.gov (United States)

    Irianto, I. D.; Dibyo, S.; Bakhri, S.; Sunaryo, G. R.

    2018-02-01

    The conversion of reactor fuel type will affect the heat transfer process resulting from the reactor core to the cooling system. This conversion resulted in changes to the cooling system performance and parameters of operation and design of key components of the reactor coolant system, especially the primary cooling system. The calculation of the operating parameters of the primary cooling system of the reactor TRIGA 2000 Bandung is done using ChemCad Package 6.1.4. The calculation of the operating parameters of the cooling system is based on mass and energy balance in each coolant flow path and unit components. Output calculation is the temperature, pressure and flow rate of the coolant used in the cooling process. The results of a simulation of the performance of the primary cooling system indicate that if the primary cooling system operates with a single pump or coolant mass flow rate of 60 kg/s, it will obtain the reactor inlet and outlet temperature respectively 32.2 °C and 40.2 °C. But if it operates with two pumps with a capacity of 75% or coolant mass flow rate of 90 kg/s, the obtained reactor inlet, and outlet temperature respectively 32.9 °C and 38.2 °C. Both models are qualified as a primary coolant for the primary coolant temperature is still below the permitted limit is 49.0 °C.

  7. Different microprocessor controlled devices for ITU TRIGA Mark II reactor

    International Nuclear Information System (INIS)

    Can, B.; Omuz, S.; Uzun, S.; Apan, H.

    1990-01-01

    In this paper the design of a period meter and multichannel thermometer, which are controlled by a microprocessor, in order to be used at ITU TRIGA Mark-II Reactor is presented. The system works as a simple microcomputer, which includes a CPU, a EPROM, a RAM, a CTC, a PIO, a PIA a keyboard and displays, using the assembly language. The period meter can work either with pulse signal or with analog signal depending on demand of the user. The period is calculated by software and its range is -99,9 sec, to +2.1 sec. When the period drops +3 sec, the system gives alarm illuminating a LED. The multichannel thermometer has eight temperature channels. Temperature channels can manually or automatically be selected. The channel selection time can be adjusted. The thermometer gives alarm illuminating a LED, when the temperature rises to 600 C. Temperature data is stored in the RAM and is shown on a display. This system provides us to use four spare thermocouples in the reactor. (orig.)

  8. Experimental and theoretical comparison of fuel temperature and bulk coolant characteristics in the Oregon State TRIGA reactor during steady state operation

    Energy Technology Data Exchange (ETDEWEB)

    Marcum, W.R., E-mail: marcumw@engr.orst.ed [Oregon State University, Department of Nuclear Engineering and Radiation Health Physics, 116 Radiation Center, Corvallis, OR 97330 (United States); Woods, B.G.; Reese, S.R. [Oregon State University, Department of Nuclear Engineering and Radiation Health Physics, 116 Radiation Center, Corvallis, OR 97330 (United States)

    2010-01-15

    In September of 2008 Oregon State University (OSU) completed its core conversion analysis as part of the Reduced Enrichment for Research and Test Reactors (RERTR) Program. Experimental bulk coolant temperatures were collected in various locations throughout the Oregon State TRIGA Reactor (OSTR) core in order to supplement the validity of the numerical thermal hydraulic results produced in RELAP5-3D Version 2.4.2. Axial bulk coolant temperature distributions were collected by acquiring discrete thermocouple measurements in individual subchannel locations during steady state operation at 1.0 MW{sub th}. The experimental axial temperature distribution collected was compared to one-channel, two-channel, and eight-channel RELAP5-3D models and found to match within 11.94%, 11.69%, and 8.78%, respectively, on average. Comparisons to similar studies were made based on a dimensional analysis of fluid body forces in the discrete core locations, indicating that the chosen approach produces conservative results for use in the OSTR safety analysis.

  9. Current activities at the FiR 1 TRIGA reactor

    International Nuclear Information System (INIS)

    Salmenhaara, Seppo

    2002-01-01

    The FiR 1 -reactor, a 250 kW Triga reactor, has been in operation since 1962. The main purpose to run the reactor is now the Boron Neutron Capture Therapy (BNCT). The epithermal neutrons needed for the irradiation of brain tumor patients are produced from the fast fission neutrons by a moderator block consisting of Al+AlF 3 (FLUENTAL), which showed to be the optimum material for this purpose. Twenty-one patients have been treated since May 1999, when the license for patient treatment was granted to the responsible BNCT treatment organization. The treatment organization has a close connection to the Helsinki University Central Hospital. The BNCT work dominates the current utilization of the reactor: three days per week for BNCT purposes and only two days per week for other purposes such as the neutron activation analysis and isotope production. In the near future the back end solutions of the spent fuel management will have a very important role in our activities. The Finnish Parliament ratified in May 2001 the Decision in Principle on the final disposal facility for spent fuel in Olkiluoto, on the western coast of Finland. There is a special condition in our operating license. We have now about two years' time to achieve a binding agreement between VTT and the Nuclear Power Plant Companies about the possibility to use the final disposal facility of the Nuclear Power Plants for our spent fuel. If this will not happen, we have to make the agreement with the USDOE with the well-known time limits. At the moment it seems to be reasonable to prepare for both spent fuel management possibilities: the domestic final disposal and the return to the USA offered by USDOE. Because the cost estimates of the both possibilities are on the same order of magnitude, the future of the reactor itself will determine, which of the spent fuel policies will be obeyed. In a couple of years' time it will be seen, if the funding of the reactor and the incomes from the BNC treatments will cover

  10. Neutronic study of nuclear reactors. Complete calculation of TRIGA MARKII reactor and calculations of fuel temperature coefficients. (Qualification of WIMS code)

    International Nuclear Information System (INIS)

    Benmansour, L.

    1992-01-01

    The present work shows a group of results, obtained by a neutronic study, concerning the TRIGA MARK II reactor and LIGHT WATER reactors. These studies aim to make cell and diffusion calculations. WIMS D-4 with extended library and DIXY programs are used and tested for those purposes. We also have proceeded to a qualification of WIMS code based on the fuel temperature coefficient calculations. 33 refs.; 23 figs.; 30 tabs. (author)

  11. Twenty years of operation of Ljubljana's TRIGA Mark II reactor

    International Nuclear Information System (INIS)

    Dimic, V.

    1986-01-01

    Twenty years have now passed since the start of the TRIGA Mark II reactor in Ljubljana. The reactor was critical on May 31, 1966. The total energy produced until the end of May 1986 was 14.048 MWh or 585 MWd. For the first 14 years (until 1981) the yearly energy produced was about 600 MWh, since 1981 the yearly energy produced was 1000 MWh when a routine radioactive isotopes production started for medical use as well as other industrial applications, such as doping and irradiation with fast neutrons of silicon monocrystals, production of level indicators (irradiated cobalt wire), production of radioactive iridium for gamma-radiography, leak detection in pipes by sodium, etc. Besides these, applied research around the reactor is being conducted in the following main fields, where- many unique methods have been developed or have found their way into the local industry or hospitals: neutron radiography, neutron induced auto-radiography using solid state nuclear track detectors, nondestructive methods for assessment of nuclear burn-up, neutron dosimetry, calculation of core burn-up for the optimal in-core fuel management strategy. The solvent extraction method was developed for the everyday production of 99m Tc, which is the most widely used radionuclide in diagnostic nuclear medicine. The methods were developed for the production of the following isotopes: 18 F, 85m Kr, 24 Na, 82 Br, 64 Zn, 125 I. Neutron activation analysis represents one of the major usages for the TRIGA reactor. Basic research is being conducted in the following main fields: solid state physics (elastic and inelastic scattering of the neutrons), neutron dosimetry, neutron radiography, reactor physics and neutron activation analysis. The reactor is used very extensively as a main instrument in the Reactor Training Centre in Ljubljana where manpower training for our nuclear power plant and other organisations has been performed. Although the reactor was designed very carefully in order to be used for

  12. Some aspects related to the management of maintenance for a TRIGA research reactor In Romania

    International Nuclear Information System (INIS)

    Vieru, G.

    2003-01-01

    Safety management for a nuclear research reactor involves 'good dependability management' of operations activities, such as: reliability, availability, maintainability and maintenance support. In order to evaluate the safety management aspects intended to be applied by research reactor management, the performance dependability indicators and their impact on reactor availability and reactor safety have to be established. The document ISO 9000-4/IEC 300-1 'Dependability Management' (1995), describes five internationally agreed indicators of reactor equipment dependability. Each of them can be used for corrective maintenance or for preventive maintenance, such as: I 1 - equipment Maintenance Frequency; I 2 - equipment Maintenance Effort; I 3 - equipment Maintenance Downtime Factor; I 4 - equipment Maintenance Contribution to the System Function Downtime Factor; I 5 - equipment Maintenance Contribution to the reactor Capability Loss Factor. This paper presents an evaluation of those 5 mentioned indicators with reference to the primary circuit of the INR's TRIGA research reactor and conclusion. The analyzed period was between 1994- 1999. It is to be noted that this type of analysis is performed for the first time for a research reactor. (author)

  13. Dynamics model for real time diagnostics of Triga RC-1 system

    International Nuclear Information System (INIS)

    Gadomski, A.M.; Nanni, V.; Meo, G.

    1988-01-01

    This paper presents dynamics model of TRIGA RC-1 reactor system. The model is dedicated to the real-time early fault detection during a reactor operation in one week exploitation cycle. The algorithms are specially suited for real-time, long time and also accelerated simulations with assumed diagnostic oriented accuracy. The approximations, modular structure, numerical methods and validation are discussed. The elaborated model will be build in the TRIGA Supervisor System and TRIGA Diagnostic Simulator

  14. Operation experience with the TRIGA Mark II reactor Vienna in the years 1972 through 1974

    International Nuclear Information System (INIS)

    Boeck, H.

    1974-01-01

    Since the last TRIGA Users Conference in Pavia 1972 the TRIGA reactor Vienna was in operation without any larger undesired shut-down. The integral thermal power production by Sept. 1, 1974 was 3420 MWh. The principal work carried out during the last two years on the reactor system was the installation of a new heat exchanger and primary pump both designed for 1 MW steady state operation. Permission was also obtained from the local authority to withdraw up to 90 m 3 /h secondary cooling water from the well. Some troubles were observed with the pulse rod. After nearly 12 years of operation the connection between the piston rod and control rod broke off just below the water surface. Therefore the piston was shot out without withdrawing the pulse rod itself. After locating the trouble the damage was repaired within one day. The SST fuel elements type 110 were received by the end of 1972 for the purpose of power upgrading. All other fuel elements except one are still located in the reactor core and shifted periodically in order to obtain an optimal burnup. A new alarm system was ordered from Hartmann and Braun and is under installation at the moment. In order to facilitate cooperation with the reactor operation personnel and the experimenters in the reactor hall an accurate power indicator has been installed in the reactor hall which allows all experimenters to read the reactor power as accurately as in the control room itself. (U.S.)

  15. Whole core neutronics modeling of a TRIGA reactor using integral transport theory

    International Nuclear Information System (INIS)

    Schwinkendorf, K.N.; Toffer, H.

    1990-01-01

    An innovative analysis approach for performing whole core reactor physics calculations for TRIGA reactors has been employed recently at the Westinghouse Hanford Company. A deterministic transport theory model with sufficient geometric complexity to evaluate asymmetric loading patterns was used. Calculations of this complexity have been performed in the past using Monte Carlo simulation, such as the MCNP code. However, the Monte Carlo calculations are more difficult to prepare and require more computer time. On the Hanford Site CRAY XMP-18 computer, the new methods required less than one-third of the central processing unit time per calculation as compared to an MCNP calculation using 100,000 neutron histories

  16. Computational Analysis of Nuclear Safety Parameters of 3 MW TRIGA Mark-II Research Reactor Based on Evaluated Nuclear Data Libraries JENDL-3.3 and ENDF/B-VII.0

    International Nuclear Information System (INIS)

    Khan, Jahirul Haque

    2013-01-01

    The objective of this study is to explain the main nuclear safety parameters of 3 MW TRIGA Mark-II Research Reactor at AERE, Savar, Dhaka, Bangladesh from the viewpoint of reactor safety and also reactor operator. The most important nuclear reactor physics safety parameters are power distribution, power peaking factors, shutdown margin, control rod worth, excess reactivity and fuel temperature reactivity coefficient. These parameters are calculated using the chain of the computer codes the SRAC-PIJ for cell calculation based on neutron transport theory and the SRAC-CITATION for core calculation based on neutron diffusion equation. To achieve this objective the TRIGA model is developed by the 3-D diffusion code SRAC-CITATION based on the group constants that come from the collision probability transport code SRAC-PIJ. In this study the evaluated nuclear data libraries JENDL-3.3 and ENDF/B-VII.0 are used. The calculated most important reactor physics parameters are compared to the safety analysis report (SAR) values as well as earlier published MCNP results (numerically benchmark). It was found that the calculated results show a good agreement between the said libraries. Besides, in most cases the calculated results reveal a reasonable agreement with the SAR values (by General Atomic) as well as the MCNP results. In addition, this analysis can be used as the inputs for thermal-hydraulic calculations of the TRIGA fresh core in the steady state and pulse mode operation. Because of power peaking factors, power distributions and temperature reactivity coefficients are the most important reactor safety parameters for normal operation and transient safety analysis in research as well as in power reactors. They form the basis for technical specifications and limitations for reactor operation such as loading pattern limitations for pulse operation (in TRIGA). Therefore, this analysis will be very important to develop the nuclear safety parameters data of 3 MW TRIGA Mark

  17. Core map generation for the ITU TRIGA Mark II research reactor using Genetic Algorithm coupled with Monte Carlo method

    Energy Technology Data Exchange (ETDEWEB)

    Türkmen, Mehmet, E-mail: tm@hacettepe.edu.tr [Nuclear Engineering Department, Hacettepe University, Beytepe Campus, Ankara (Turkey); Çolak, Üner [Energy Institute, Istanbul Technical University, Ayazağa Campus, Maslak, Istanbul (Turkey); Ergün, Şule [Nuclear Engineering Department, Hacettepe University, Beytepe Campus, Ankara (Turkey)

    2015-12-15

    Highlights: • Optimum core maps were generated for the ITU TRIGA Mark II Research Reactor. • Calculations were performed using a Monte Carlo based reactor physics code, MCNP. • Single-Objective and Multi-Objective Genetic Algorithms were used for the optimization. • k{sub eff} and ppf{sub max} were considered as the optimization objectives. • The generated core maps were compared with the fresh core map. - Abstract: The main purpose of this study is to present the results of Core Map (CM) generation calculations for the İstanbul Technical University TRIGA Mark II Research Reactor by using Genetic Algorithms (GA) coupled with a Monte Carlo (MC) based-particle transport code. Optimization problems under consideration are: (i) maximization of the core excess reactivity (ρ{sub ex}) using Single-Objective GA when the burned fuel elements with no fresh fuel elements are used, (ii) maximization of the ρ{sub ex} and minimization of maximum power peaking factor (ppf{sub max}) using Multi-Objective GA when the burned fuels with fresh fuels are used. The results were obtained when all the control rods are fully withdrawn. ρ{sub ex} and ppf{sub max} values of the produced best CMs were provided. Core-averaged neutron spectrum, and variation of neutron fluxes with respect to radial distance were presented for the best CMs. The results show that it is possible to find an optimum CM with an excess reactivity of 1.17 when the burned fuels are used. In the case of a mix of burned fuels and fresh fuels, the best pattern has an excess reactivity of 1.19 with a maximum peaking factor of 1.4843. In addition, when compared with the fresh CM, the thermal fluxes of the generated CMs decrease by about 2% while change in the fast fluxes is about 1%.Classification: J. Core physics.

  18. Tests for removal of Co-60 and Eu-154 from irradiated graphite in the TRIGA Reactor

    International Nuclear Information System (INIS)

    Arsene, Carmen

    2009-01-01

    The irradiated graphite in Romania is mainly generated in the thermal columns of TRIGA and WWER-S research reactors (about 9 tones). It was found that the radionuclide content of the graphite irradiated in the TRIGA research reactor is mainly due to C-14 (103 Bq/g), Eu-152 (600-700 Bq/g) and Co-60 (130-150 Bq/g) and low amounts of Eu-154 and Cs-137, depending on location in the thermal column and on irradiation history. In order to minimize the waste inventory and volume in view of their final disposal, in the present paper we show the results of experiments performed for developing and optimizing methods for the chemical decontamination of the irradiated graphite. These procedures are based on strong alkaline solutions for Eu-152 and strong acid solutions for Co-60. The influence of the process parameters on the decontamination factor is investigated. (authors)

  19. Calculations and selection of a TRIGA core for the Nuclear Reactor IAN-R1

    International Nuclear Information System (INIS)

    Castiblanco, L.A.; Sarta, J.A.

    1997-01-01

    The Reactor Group used the code WIMS reduced to five groups of energy, together with the code CITATION, and evaluated four configurations for a core, according to the grid actually installed. The four configurations were taken from the two proposals presented to the Instituto de Ciencias Nucleares y Energias Alternativas by General Atomics Company. In this paper, the Authors selected the best configuration according to the performance of flux distribution and excess reactivity, for a TRIGA core to be installed in the Nuclear Reactor IAN-R1

  20. Research with Neutrons at the TRIGA Mainz

    International Nuclear Information System (INIS)

    Hampel, Gabriele

    2008-01-01

    The TRIGA Mark II reactor at the Institut fuer Kernchemie of the Johannes Gutenberg-Universitaet in Mainz became first critical on August 3, 1965 and is still intensively used for basic research, applied science and educational purposes. Considering the past and future operation schedule and the low burn-up of the fuel elements (∼4 g 235 U/a), the reactor can be operated for at least the next decade taking into account the fresh fuel elements on stock and without changing spent fuels. The operation of the TRIGA Mainz has been extended very recently until the year 2020. The TRIGA Mainz can be operated in the steady state mode with a maximum power of 100 kWth and in the pulse mode with a peak power of 250 MWth. Until now, more than 16600 pulses have been carried out without any fuel failure. For irradiations the TRIGA Mainz has a central experimental tube, three pneumatic transfer systems and a rotary specimen rack with 40 positions which allows the irradiation of 80 samples at the same time. In addition, the TRIGA Mainz includes four horizontal beam ports penetrating the concrete shielding and extending inside the pool towards the reflector. A graphite thermal column provides a source of well-thermalized neutrons suitable for physical research or biological and medical irradiations. Important projects for the future of the TRIGA Mainz are the production of ultracold neutrons (UCN) and experiments with UCN, high precision mass measurements and laser spectroscopy of short-lived fission products (TRIGA-TRAP), the production of radionuclides for fast chemical separations, medical and radiopharmaceutical applications, and the use of the neutron activation analysis for the application in archeometry, solar energy technique, criminalistics and vine analysis. Furthermore, studies are performed to judge if the Boron Neutron Capture Therapy (BNCT) can be applied at the TRIGA Mainz for cancer treatment of liver metastases. Also, the reactor facility is used for the training

  1. Release procedure according to paragraph 29 StrlSchv on example of the nuclear research reactor TRIGA Heidelberg II; Durchfuehrung von Freigabeverfahren nach paragraph 29 am Beispiel des TRIGA Heidelberg II

    Energy Technology Data Exchange (ETDEWEB)

    Cremer, J. [Siempelkamp Nukleartechnik GmbH (SNT) (Germany); Sold, A. [Deutsches Krebsforschungszentrum Heidelberg (DKFZ) (Germany)

    2005-07-01

    The aim of this lecture is to show the schedule of a release procedure according to paragraph 29 StrlSchV on the example of the decommissioning of the nuclear research reactor TRIGA Heidelberg II. It is shown on the effort done by the radiation protection representative of this plant. Considering this example, starting with planning, application, survey and execution, the complex context of the release procedure is becomes apparent. Thereby the new applied measuring techniques that require a certain practice and the responsibility of the radiation protection representative in the radiation protection law play a relevant role. In such small facilities as the TRIGA Heidelberg II, the radiation protection staff are employed according to the plant's size and work is focussed on radiation protection research and laboratories. The decommissioning process with its wide range of radiation protection requirements represents new challenges which have to be coordinated with the present duties of the radiation protection representative. The supervision and the responsibility for the release procedure according to paragraph 29 are the largest and the most sensitive part of decommissioning of the nuclear research reactor TRIGA Heidelberg II. (orig.)

  2. Derived release limits for airborne effluents at TRIGA - INR Reactor

    International Nuclear Information System (INIS)

    Toma, A.; Dulama, C.; Hirica, O.; Mihai, S.; Oprea, I.

    2008-01-01

    Beginning from fulfilling the purposes of dose limitation system recommended by ICRP, and now accepted in radiation protection, this paper presents an environmental transfer model to calculate derived release limits for airborne and gaseous radioactive effluents at TRIGA-INR, 14 MW Steady State Reactor, in function on INR-Pitesti site. The methodology consists in determination of the principal exposure pathways for different groups of population and dose calculations for each radionuclide. The characterization of radionuclides transfer to environment was made using the compartmental model. The parameter transfer concept was used to describe the distribution of radionuclides between the different compartments. Atmospheric dispersion was very carefully treated, because it is the primary mechanism of the transfer of radionuclides in the environment and it determines all exposure pathways. Calculation of the atmospheric dispersion was made using ORION-II computer code based on the Gaussian plume model which takes account of site's specific climate and relief conditions. Default values recommended by literature were used to calculate some of the parameters when specific site values were not available. After identification of all transfer parameters which characterize the most important exposure pathways, the release rate corresponding to the individual dose rate limit was calculated. This maximum release rate is the derived release limit for each radionuclide and source. In the paper, the derived release limits are calculated for noble gases, radioiodine and other airborne particulate radionuclides, which can be released on the TRIGA-INR reactor stack, and are important to radiation protection. (authors)

  3. Neutron spectra in two beam ports of the TRIGA Mark III reactor

    International Nuclear Information System (INIS)

    Vega C, H. R.; Hernandez D, V. M.; Aguilar, F.; Paredes, L.; Rivera M, T.

    2013-10-01

    The neutron spectra have been measured in two beam ports, radial and tangential, of the TRIGA Mark III nuclear reactor from the National Institute of Nuclear Research. Measurements were carried out with the core with mixed fuel (Leu 8.5/20 and Flip Heu 8.5/70). Two reactor powers, 5 and 10 W, were used during neutron spectra measurements using a Bonner sphere spectrometer with a 6 Lil(Eu) scintillator and 2, 3, 5, 8, 10 and 12 inches-diameter high density polyethylene spheres. The neutron spectra were unfolded using the NSDUAZ unfolding code; from each spectrum the total neutron flux, the neutron mean energy and the neutron ambient dose equivalent dose were determined. Measured spectra show fission (E≥ 0.1 MeV), epithermal (from 0.4 eV up to 0.1 MeV) and thermal neutrons (E≤ 0.4 eV). For both reactor powers the spectra in the radial beam port have similar features which are different to the neutron spectrum characteristics in the tangential beam port. (Author)

  4. Neutron spectra in two beam ports of the TRIGA Mark III reactor

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H. R.; Hernandez D, V. M. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98060 Zacatecas (Mexico); Aguilar, F.; Paredes, L. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Rivera M, T., E-mail: fermineutron@yahoo.com [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Unidad Legaria, Av. Legaria 694, 11500 Mexico D. F. (Mexico)

    2013-10-15

    The neutron spectra have been measured in two beam ports, radial and tangential, of the TRIGA Mark III nuclear reactor from the National Institute of Nuclear Research. Measurements were carried out with the core with mixed fuel (Leu 8.5/20 and Flip Heu 8.5/70). Two reactor powers, 5 and 10 W, were used during neutron spectra measurements using a Bonner sphere spectrometer with a {sup 6}Lil(Eu) scintillator and 2, 3, 5, 8, 10 and 12 inches-diameter high density polyethylene spheres. The neutron spectra were unfolded using the NSDUAZ unfolding code; from each spectrum the total neutron flux, the neutron mean energy and the neutron ambient dose equivalent dose were determined. Measured spectra show fission (E≥ 0.1 MeV), epithermal (from 0.4 eV up to 0.1 MeV) and thermal neutrons (E≤ 0.4 eV). For both reactor powers the spectra in the radial beam port have similar features which are different to the neutron spectrum characteristics in the tangential beam port. (Author)

  5. Dynamics model for real time diagnostics of TRIGA RC-1 system

    International Nuclear Information System (INIS)

    Gadomski, A.M.; Nanni, V.; Meo, G.B.

    1986-01-01

    This paper presents dynamics model of TRIGA RC-1 reactor system. The model is dedicated to the real-time early fault detection during a reactor operation in one week exploitation cycle. The algorithms are specially suited for real-time, long time and also accelerated simulations with assumed diagnostic oriented accuracy. The approximations, modular structure, numerical methods and validation are discussed. The elaborated model will be build in the TRIGA Supervisory System and TRIGA Diagnostic Simulator. (author)

  6. Mechanism design for the control rods conduction of TRIGA Mark III reactor in the NINR

    International Nuclear Information System (INIS)

    Franco C, A.

    1997-01-01

    This work presents in the first chapter a general studio about the reactor and the importance of control rods in the reactor , the mechaniucal design attending to requisitions that are imposed for conditions of operation of the reactor are present in the second chapter, the narrow relation that exists with the new control console and the mechanism is developed in the thired chapter, this relation from a point of view of an assembly of components is presents in fourth chapter, finally reaches and perspectives of mechanism forming part of project of the automation of reactor TRIGA MARK III, are present in the fifth chapter. (Author)

  7. Nine years of operation of ITU-TRR TRIGA Mark-II reactor

    International Nuclear Information System (INIS)

    Yavuz, H.; Bayuelken, A.R.; Yavuz, M.A.

    1988-01-01

    ITU-TRR TRIGA Mark-II reactor in Istanbul with a steady state power of 250 kW and a pulsing capability up to 1200 MW has been operating since March 11,1979 with an energy release of 107.5 MWh and a total of 72 pulses. During this nearly nine years, the reactor was in operation without any major undesired shut down. One of the major problems was faced when the instrumented fuel element in position 9 of the F ring went totally out of order. Secondly, the cooling tower of the secondary cooling system could not be operated properly during the hot summer days, and also we had a tar leakage problem with the radial beam port connection to the tank. During the regular maintenance work in this summer, the measurements of changes in nuclear and physical parameters of the reactor fuel and dummy elements have also proceeded. (author)

  8. The new area monitoring system and the fuel database of the TRIGA Mark II reactor in Vienna

    International Nuclear Information System (INIS)

    Villa, M.; Boeck, H.; Hofbauer, M.; Schwarz, V.

    2004-01-01

    The 250 kW TRIGA Mark-II reactor operates since March 1962 at the Atominstitut, Vienna, Austria. Its main tasks are nuclear education and training in the fields of neutron- and solid state physics, nuclear technology, reactor safety, radiochemistry, radiation protection and dosimetry, and low temperature physics and fusion research. Academic research is carried out by students in the above mentioned fields coordinated and supervised by about 70 staff members with the aim of a masters- or PhD degree in one of the above mentioned areas. After 25 years of successful operation, it was necessary to exchange the old area monitoring system with a new digital one. The purpose of the new system is the permanent control of the reactor hall, the primary and secondary cooling system and the monitoring of the ventilation system. The paper describes the development and implementation of the new area monitoring system. The second topic in this paper describes the development of the new fuel database. Since March 7th, 1962, the TRIGA Mark II reactor Vienna operates with an average of 263 MWh per year, which corresponds to a uranium burn-up of 13.7 g per year. Presently we have 81 TRIGA fuel elements in the core, 55 of them are old aluminium clad elements from the initial criticality while the rest are stainless steel clad elements which had been added later to compensate the uranium consumption. Because 67 % of the elements are older than 40 years, it was necessary to put the history of every element in a database, to get an easy access to all the relevant data for every element in our facility. (author)

  9. A history of effluent releases from the Texas A and M University reactor

    Energy Technology Data Exchange (ETDEWEB)

    Bates, E F; Neff, R D; Sandel, P S; Schoenbucher, B [Texas A and M University (United States)

    1974-07-01

    Since 1966 records of radioactive effluents releases from the Texas A and M University Research Reactor have been compiled. These data include particulate activity, noble gases, and liquid effluent releases. Particulate activity releases with half-lives greater than eight days were negligible and are not included in this presentation. Conversion from an MTR plate reactor to a TRIGA fueled reactor was completed in August 1968. Records of effluent releases of Argon-4l and liquids for the past, five years are summarized, in this presentation. These release data are compared to the current limits specified: in 10 CPR 20 and the limits appearing in proposed Appendix.

  10. Operational experience of decommissioning techniques for research reactors in the United Kingdom

    International Nuclear Information System (INIS)

    England, M.R.; McCool, T.M.

    2002-01-01

    In previous co-ordinated research projects (CRP) conducted by the IAEA no distinction was made between decommissioning activities carried out at nuclear power plants, research reactors or nuclear fuel cycle facilities. As experience was gained and technology advanced it became clear that decommissioning of research reactors had certain specific characteristics which needed a dedicated approach. It was within this context that a CRP on Decommissioning Techniques for Research Reactors was launched and conducted by the IAEA from 1997 to 2001. This paper considers the experience gained from the decommissioning of two research reactors during the course of the CRP namely: (a) the ICI Triga Mk I reactor at Billingham UK which was largely complete by the end of the research project and (b) the Argonaut 100 reactor at the Scottish Universities Research and Reactor centre at East Kilbride in Scotland which is currently is the early stages of dismantling/site operations. It is the intention of this paper with reference to the two case studies outlined above to compare the actual implementation of these works against the original proposals and identify areas that were found to be problematical and/or identify any lessons learnt. (author)

  11. TRIGLAV-W a Windows computer program package with graphical users interface for TRIGA reactor core management calculations

    International Nuclear Information System (INIS)

    Zagar, T.; Zefran, B.; Slavic, S.; Snoj, L.; Ravnik, M.

    2006-01-01

    TRIGLAV-W is a program package for reactor calculations of TRIGA Mark II research reactor cores. This program package runs under Microsoft Windows operating system and has new friendly graphical user interface (GUI). The main part of the package is the TRIGLAV code based on two dimensional diffusion approximation for flux distribution calculation. The new GUI helps the user to prepare the input files, runs the main code and displays the output files. TRIGLAV-W has a user friendly GUI also for the visualisation of the calculation results. Calculation results can be visualised using 2D and 3D coloured graphs for easy presentations and analysis. In the paper the many options of the new GUI are presented along with the results of extensive testing of the program. The results of the TRIGLAV-W program package were compared with the results of WIMS-D and MCNP code for calculations of TRIGA benchmark. TRIGLAV-W program was also tested using several libraries developed under IAEA WIMS-D Library Update Project. Additional literature and application form for TRIGLAV-W program package beta testing can be found at http://www.rcp.ijs.si/triglav/. (author)

  12. Experimental measurement of the refrigerant temperature of the TRIGA Mark III reactor of the ININ

    International Nuclear Information System (INIS)

    Gallardo S, L.F.; Alonso V, G.

    1991-08-01

    With the object of knowing the axial temperature profile of the refrigerant in the core of the TRIGA Mark III reactor of the ININ, the temperatures of this, at the enter, in the center and the exit of the core were measured, in the positions: west 2, north 2 and south 1. This was made by means of the thermo pars introduction mounted in aluminum guides, connected to a measurer of digital temperature, whose resolution is of ± 0.1 C. The measurements showed a bigger heating of the refrigerant in the superior half of the core, that which suggests that the axial profile of temperature of the reactor is not symmetrical with respect to the center or that those temperature measurements in the center are not correct. (Author)

  13. Proposal of a system for fuel elements inspection of CDTN TRIGA nuclear reactor

    International Nuclear Information System (INIS)

    Rodrigues, Rogerio Rivail; Mesquita, Amir Zacarias

    2013-01-01

    The CDTN has in its facilities a TRIGA-type nuclear reactor. The reactor's cooling water must be treated and managed with the goal of keeping its low conductivity to minimize corrosion of the reactor components, mainly of fuel elements (FE), and reduce the level of radioactivity. The aim of this paper is to present a proposal for the development of a system for verification of some possible leaks in FE nuclear research reactors, based on the sipping test. This type of testing is a way to check for leaks of fission products from fuel element of nuclear research reactor. In the future, when the test will do, it will have a correlation between the components found in the reactor cooling water pool and integrity of nuclear fuel elements. The device development and its application will be presented here, covering results that were not previously investigated yet, giving originality to this project. (author)

  14. A preliminary report on methods of measuring and reducing Argon-41 production by a TRIGA reactor

    International Nuclear Information System (INIS)

    Smith, W.L.

    1972-01-01

    Methods to accurately determine and techniques to reduce the Argon-41 released from the one-megawatt Geological Survey TRIGA Reactor facility have been developed. Knowledge of the composition of the exhaust-gas effluent is of prime importance to the U.S. Geological Survey in minimizing all radioactive releases to the environment. The counting systems and control measures have enabled the Geological Survey TRIGA Reactor staff to reduce the amount of Argon-41 released from the facility by a factor of two, with no reduction in operation level of the reactor. The counting system has also enabled the staff to categorize the principal sources of Argon-41. Under normal conditions, a fully-loaded rotating-specimen rack is by far the largest contributor. With the current counting system, 10 -7 microcuries per cubic centimeter can be detected in the exhaust stack. It is intended to further improve this system to increase both the sensitivity and the reliability. The sensitivity is expected to be increased by utilizing a larger counting volume. To improve the reliability, it is planned to fabricate a loop parallel to the exhaust system, eliminating the need for a separate pump. (author)

  15. 77 FR 7613 - Dow Chemical Company; Dow Chemical TRIGA Research Reactor; Facility Operating License No. R-108

    Science.gov (United States)

    2012-02-13

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 50-264; NRC-2012-0026] Dow Chemical Company; Dow Chemical TRIGA Research Reactor; Facility Operating License No. R-108 AGENCY: Nuclear Regulatory Commission... Facility Operating License No. R-108 (``Application''), which currently authorizes the Dow Chemical Company...

  16. Status of the TRIGA shipments to the INEEL from Europe

    International Nuclear Information System (INIS)

    Mustin, T.; Stump, R.C.; Tyacke, M.J.

    1997-01-01

    This paper reports the activities underway by the US Department of Energy (DOE) for returning Training, Research, Isotope, General Atomics (TRIGA) spent nuclear fuel (SNF) from foreign research reactors (FRR) in four European countries to the Idaho National Engineering and Environmental Laboratory (INEEL). Those countries are Germany, Italy, Romania, and Slovenia. This is part of the ''Nuclear Weapons Nonproliferation Policy'' of returning research reactor SNF containing uranium enriched in the US. This paper describes the results of a pre-assessment trip in September, 1997, to these countries, including: history of the reactors and research being performed; inventory of TRIGA SNF; fuel types (stainless steel, aluminum, or Incoloy) and enrichments; and each country's plans for returning their TRIGA SNF to the INEEL

  17. Nuclear science and engineering education at a university research reactor

    International Nuclear Information System (INIS)

    Loveland, W.

    1990-01-01

    The research and teaching operations of the Nuclear Chemistry Division of the Dept. of Chemistry and the Dept. of Nuclear Engineering are housed at the Oregon State University Radiation Center. This facility which includes a 1.1 MW TRIGA reactor was used for 53 classes from a number of different academic departments last year. About one-half of these classes used the reactor and ∼25% of the reactor's 45 hour week was devoted to teaching. Descriptions will be given of reactor-oriented instructional programs in nuclear engineering, radiation health and nuclear chemistry. In nuclear chemistry, classes in (a) nuclear chemistry for nuclear engineers, (b) radiotracer methods, (c) elementary and advanced activation analysis, and (d) advanced nuclear instrumentation will be described in detail. The use of the facility to promote general nuclear literacy among college students, high school and grade school students and the general population will also be covered

  18. Forensic INAA of bullet-lead and shotshell-pellet evidence specimens with a TRIGA reactor

    International Nuclear Information System (INIS)

    Guinn, Vincent P.

    1988-01-01

    This paper has been published earlier, in the references cited. The main purpose of this paper is to acquaint interested TRIGA reactor groups with the main features of the Forensic INAA of BL and SSP evidence specimens - and to recommend that they consider acquiring the necessary expertise and then provide such analysis services to law enforcement agencies, public defenders, and defence attorneys in their respective areas

  19. Assessment of the technical specifications for a flip-standard TRIGA core

    International Nuclear Information System (INIS)

    Feltz, D.E.; Randall, J.D.

    1974-01-01

    The Technical Specifications for the Texas A and M University mixed, FLIP-Standard TRIGA core were the first submitted and approved under the draft version of Standard ANS-15.1. According to one AEC official these were the best Technical Specifications ever issued to a Research Reactor. The Technical Specifications are evaluated after operating under them for over seven months. (author)

  20. Assessment of the technical specifications for a flip-standard TRIGA core

    Energy Technology Data Exchange (ETDEWEB)

    Feltz, D E; Randall, J D [Texas A and M University (United States)

    1974-07-01

    The Technical Specifications for the Texas A and M University mixed, FLIP-Standard TRIGA core were the first submitted and approved under the draft version of Standard ANS-15.1. According to one AEC official these were the best Technical Specifications ever issued to a Research Reactor. The Technical Specifications are evaluated after operating under them for over seven months. (author)

  1. 77 FR 68155 - The Armed Forces Radiobiology Research Institute TRIGA Reactor: Facility Operating License No. R-84

    Science.gov (United States)

    2012-11-15

    ... Research Institute TRIGA Reactor: Facility Operating License No. R-84 AGENCY: Nuclear Regulatory Commission... considering an application for the renewal of Facility Operating License No. R-84 (Application), which... the renewal of Facility Operating License No. R-84, which currently authorizes the licensee to operate...

  2. Assessment results of the Indonesian TRIGA SNF to be shipped to INEEL

    International Nuclear Information System (INIS)

    Jefimoff, J.; Robb, A.K.; Wendt, K.M.; Syarip, I.; Alfa, T.

    1997-01-01

    This paper describes the Training, Research, Isotope, General Atomics (TRIGA) spent nuclear fuel (SNF) examination performed by technical personnel from the Idaho National Engineering and Environmental Laboratory (INEEL) at the Bandung and Yogyakarta research reactor facilities in Indonesia. The examination was required before the SNF would be accepted for transportation to and storage at the INEEL. This paper delineates the Initial Preparations prior to the Indonesian foreign research reactor (FRR) fuel examination. The technical basis for the examination, the TRIGA SNF Acceptance Criteria, and the physical condition required for transportation, receipt and storage of the TRIGA SNF at the INEEL is explained. In addition to the initial preparations, preparation descriptions of the Work Plan For TRIGA Fuel Examination, the Underwater Examination Equipment used, and personnel Examination Team Training are included. Finally, the Fuel Examination and Results of the aluminum and stainless steel clad TRIGA fuel examination have been summarized. Lessons learned from all the activities completed to date is provided in an addendum. The initial preparations included: (1) coordination between the INEEL, FRR or Badan Tenaga Atom Nasional (BATAN), DOE-HQ, and the US State Department and Embassy; (2) incorporating Savannah River Site (SRS) FRR experience and lessons learned; (3) collecting both FRR facility and spent fuel data, and issuing a radionuclide report (Radionuclide Mass Inventory, Activity, Decay Heat, and Dose Rate Parametric Data for TRIGA Spent Nuclear Fuels) needed for transportation and fuel acceptance at the INEEL; and (4) preexamination work at the research reactor for the fuel examination

  3. Shipment of TRIGA spent fuel to DOE's INEEL site - a status report

    International Nuclear Information System (INIS)

    Patterson, John; Viebrock, James; Shelton, Tom; Parker, Dixon

    1998-01-01

    DOE placed its transportation services contract with NAC International in April 1997 and awarded the first task to NAC for return of TRIGA fuel in July 1997. This initial shipment of TRIGA fuel, scheduled for early 1998, is reflective of many of the difficulties faced by DOE and the transportation services contractor in return of the foreign research reactor fuel to the United States: 1) First time use of the INEEL dry storage facility for receipt of research reactor fuel; 2) Safety analysis of the INEEL facility for the NAC-LWT shipping cask; 3) Cask certification for a mixed loading of high enriched and low enriched TRIGA fuels; 4) Cask loading for standard length and extended length rods (instrumented and fuel follower control rods); 5) Design and certification of a canister for degraded TRIGA fuel; 6) Initial port entry through the Naval Weapons Station in Concord, California; 7) Initial approval of the rail route for shipment from Concord to INEEL. In this presentation we describe the overall activities involved in the first TRIGA shipment, discuss the actions required to resolve the difficulties identified above, and provide a status report of the initial shipment from South Korea and Indonesia. Recommendations are presented as to actions that can be taken by the research reactor operator, by DOE, and by the transportation services agent to speed and simplify the transportation process. Actions having the potential to reduce costs to DOE and to reactor operators from high-income economies will be identified. (author)

  4. Thirteen[th] European TRIGA users conference. Proceedings

    International Nuclear Information System (INIS)

    1994-01-01

    The conference covers topic related to TRIGA reactor, such as reactor operation and maintenance experience - safety aspects; research activities and applications; boron neutron capture therapy (BNCT) projects and other design operational and safety issues

  5. Activation of TRIGA Mark II research reactor concrete shield

    International Nuclear Information System (INIS)

    Zagar, Tomaz; Ravnik, Matjaz; Bozic, Matjaz

    2002-01-01

    To determine neutron activation inside the TRIGA research reactor concrete body a special sample-holder for irradiation inside horizontal channel was developed and tested. In the sample-holder various samples can be irradiated at different concrete shielding depths. In this paper the description of the sample-holder, experiment conditions and results of long-lived activation measurements are given. Long-lived neutron-induced gamma-ray-emitting radioactive nuclides in the samples were measured with HPGe detector. The most active long-lived radioactive nuclides in ordinary concrete samples were found to be 60 Co and 152 Eu and in barytes concrete samples 60 Co, 152 Eu and 133 Ba. Measured activity density of all nuclides was found to decrease almost linearly with depth in logarithmic scale. (author)

  6. Comparison of Instrumentation and Control Parameters Based on Simulation and Experimental Data for Reactor TRIGA PUSPATI

    International Nuclear Information System (INIS)

    Anith Khairunnisa Ghazali; Mohd Sabri Minhat

    2015-01-01

    Reactor TRIGA PUSPATI (RTP) undergoes safe operation for more than 30 years and the only research reactor in Malaysia. The main safety feature of Instrumentation and Control (I and C) system design is such that any failure in the electronic, or its associated components, does not lead to an uncontrolled rate of reactivity. There are no best models for RTP simulation was designed for study and research. Therefore, the comparison for I&C parameters are very essential, to design the best RTP model using MATLAB/ Simulink as close as the RTP. The simulation of TRIGA reactor type already develop using desktop reactor simulator such as Personal Computer Transient Analyzer (PCTRAN). The experimental data from RTP and simulation of PCTRAN shows some similarities and differences due to certain limitation. Currently, the structured RTP simulation was designed using MATLAB and Simulink tool that consist of ideal fission chamber, controller, control rod position, height to worth and RTP model. The study on this paper focus on comparison between real data from RTP and simulation result from PCTRAN on I&C parameters such as water level, fuel temperature, bulk temperature, power rated and rod position. The error analysis due to some similarities and differences of I&C parameters shall be obtained and analysed. The result will be used as reference for proposed new structured of RTP model. (author)

  7. Experience with effluent release from the Omaha V. A. Hospital TRIGA reactor

    Energy Technology Data Exchange (ETDEWEB)

    Blotcky, A J [Veterans Administration Hospital (United States)

    1974-07-01

    The effluent release from experiments is controlled by limiting the size of each sample irradiated so that if it was accidentally completely volatized into the closed room, the radioactive concentration would not exceed the permitted limits. The possible releases of Ar-41 and N-16 from the reactor are also considered. The experimentally determined levels of radiation around the Omaha facility are shown. From the data and calculations it was concluded that the levels of effluent release from the Omaha TRIGA are very small.

  8. Experience with effluent release from the Omaha V. A. Hospital TRIGA reactor

    International Nuclear Information System (INIS)

    Blotcky, A.J.

    1974-01-01

    The effluent release from experiments is controlled by limiting the size of each sample irradiated so that if it was accidentally completely volatized into the closed room, the radioactive concentration would not exceed the permitted limits. The possible releases of Ar-41 and N-16 from the reactor are also considered. The experimentally determined levels of radiation around the Omaha facility are shown. From the data and calculations it was concluded that the levels of effluent release from the Omaha TRIGA are very small

  9. Operational experience at the AFRRI-TRIGA reactor facility (1972-1974)

    Energy Technology Data Exchange (ETDEWEB)

    McKenzie, J L [Armed Forces Radiobiology Research Institute, Bethesda, MD (United States)

    1974-07-01

    The Armed Forces Radiobiology Research Institute operates a TRIGA Mark-F Reactor which has a movable core, and the capability to operate in the steady state mode up to a maximum power level of one megawatt and in the pulse mode up to a maximum peak power of 2600 MW (10 millisecond pulse). The reactor experienced three operational incidents during the period from February 1972 to February 1974, and two of these incidents were reportable to the Atomic Energy Commission. The first incident consisted of a failure of a weld at the top of the tri-flute on an instrumented fuel element which allowed the tri-flute to move up about one-half inch from its normal position. The instrumented fuel element was removed from the reactor core and replaced with a new instrumented fuel element. The second incident consisted of a malfunction of the reactor core position safety interlock which resulted in the lead shield doors closing around the reactor core shroud. The lead shield doors did not make contact with the reactor core shroud and therefore no damage occurred. The incident was reported to the Atomic Energy Commission. The third incident consisted of a failure of the threaded connector on the top of the transient control rod which allowed the transient control rod to separate from the connecting rod and drop to the bottom of the guide tube. The damaged transient control rod was removed from the guide tube and a new transient rod was installed in the reactor core. This incident was reported to the Atomic Energy Commission. A modification was made to Exposure Room 2 which consisted of placing panels, painted with gadolinium oxide paint, on the walls, ceiling, and reactor core tank projection. This resulted in the {sup 41}Ar production rate and the effluent release to the environment being reduced by a factor of 10 to 20, depending upon the position of the reactor core. (author)

  10. Operational experience at the AFRRI-TRIGA reactor facility (1972-1974)

    International Nuclear Information System (INIS)

    McKenzie, J.L.

    1974-01-01

    The Armed Forces Radiobiology Research Institute operates a TRIGA Mark-F Reactor which has a movable core, and the capability to operate in the steady state mode up to a maximum power level of one megawatt and in the pulse mode up to a maximum peak power of 2600 MW (10 millisecond pulse). The reactor experienced three operational incidents during the period from February 1972 to February 1974, and two of these incidents were reportable to the Atomic Energy Commission. The first incident consisted of a failure of a weld at the top of the tri-flute on an instrumented fuel element which allowed the tri-flute to move up about one-half inch from its normal position. The instrumented fuel element was removed from the reactor core and replaced with a new instrumented fuel element. The second incident consisted of a malfunction of the reactor core position safety interlock which resulted in the lead shield doors closing around the reactor core shroud. The lead shield doors did not make contact with the reactor core shroud and therefore no damage occurred. The incident was reported to the Atomic Energy Commission. The third incident consisted of a failure of the threaded connector on the top of the transient control rod which allowed the transient control rod to separate from the connecting rod and drop to the bottom of the guide tube. The damaged transient control rod was removed from the guide tube and a new transient rod was installed in the reactor core. This incident was reported to the Atomic Energy Commission. A modification was made to Exposure Room 2 which consisted of placing panels, painted with gadolinium oxide paint, on the walls, ceiling, and reactor core tank projection. This resulted in the 41 Ar production rate and the effluent release to the environment being reduced by a factor of 10 to 20, depending upon the position of the reactor core. (author)

  11. Personal Dosemeter of Thermal Neutron Using A Cr-39 Detector with Filter Natural LiF

    International Nuclear Information System (INIS)

    Sofyan, Hasnel; Thamrin, M.Thoyib

    1996-01-01

    The research of personal dosemeter for thermal neutron using Cr-39 detector with different thicknesses of natural LiF filter was carried out. The irradiation of Cr-39 detector with neutron source from reactor research TRIGA mark II of Rikkyo University Tokyo, Japan. Nuclear track was counted by automatic method with ASPECT ver.4.22 Series A4T124 software and manual method for correction. The result of research, the maximum of nuclear tracks was obtained at 8 mm of LiF filter was 10 mm with 11,630x10E-5 track/neutron for air radiation. And on phantom radiation, the thickness of filter was 10 mm with 11,630x10E-5 track/neutron. Its values were 3.6 and 7.5 bigger than the response of Cr-39 non filter in air and on phantom radiation, respectively

  12. Development of slow neutron dose meter by track counting

    International Nuclear Information System (INIS)

    Nozaki, Tetsuya; Takeuchi, Hiroshi; Hasnel, S.; Honda, Teruyuki; Harasawa, Susumu.

    1993-01-01

    Prototypes of a plate type and two types of semispherical dosemeter were manufactured and their performances were tested. Polyallyl diglycol carbonate (PADC) was employed as neutron detector and covered with natural LiF and 6 Li-enriched LiF ceramics. They were irradiated in the TRIGA II Reactor of the Rikkyo University, and the sensitivity characteristics for incident angles and neutron energies were analyzed. It is concluded that it may be possible to manufacture small sized neutron dosemeter of flat response to wide energy range from thermal neutrons to epithermal neutrons with sufficient sensitivity for personal monitoring, using LiF ceramic as neutron filters and neutron converters. However the following issues are to be solved: the optimization of thickness of the LiF filter, the effects of albedo of the human body, and the applicability to the intermediate neutrons. (A.Y.)

  13. An Overview of Ageing Management Programme for PUSPATI TRIGA Reactor (RTP)

    International Nuclear Information System (INIS)

    Syahirah Abdul Rahman; Mohamad Azman Che Mat Isa; Mohd Zaid Mohamed

    2011-01-01

    The PUSPATI TRIGA reactor (RTP) at Malaysian Nuclear Agency which has been operating for 29 years now faces increasingly serious aging problems. Many components are obsolete whereas genuine parts are no longer in the market. Currently, the aging problem is addressed through periodic maintenance on all systems, structures and components (SSC). As a holistic measure, the Aging Management Program (AMP) was formulated to solve the problems from the grassroots. This paper describes the first stage of the AMP which identifies the strengths and capabilities. This includes identifying the types of aging, responsible parties and relationship between aging problems and safety of RTP. (author)

  14. Thermal neutron flux measurements in the rotary specimen rack of the IPR-R1 TRIGA reactor

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Rose Mary G. do Prado; Rodrigues, Rogério R.; Souza, Luiz Claudio A., E-mail: souzarm@cdtn.br, E-mail: rrr@cdtn.br, E-mail: lcas@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    The thermal neutron flux in the rotary specimen rack of the IPR-R1 TRIGA reactor at the Nuclear Technology Development Center (CDTN), Belo Horizonte, Brazil, has been measured by the neutron activation method, using bare and cadmium covered gold foils. Those foils were irradiated in the rotary specimen rack with the reactor at 100 kW. The reactor core configuration has 63 fuel elements, composed of 59 original aluminum-clad elements and 4 stainless steel-clad fuel elements. The gamma activities of the foils were measured using Ge spectrometer. The perturbations of the thermal neutron flux caused by the introduction of an absorbing foil into the medium were considered in order to obtain accurate determination of the flux. The thermal neutron flux obtained was 7.4 x 10{sup 11} n.cm{sup -2}.s{sup -1}. (author)

  15. Reactor console replacement at Washington State University

    International Nuclear Information System (INIS)

    Lovas, Thomas A.

    1978-01-01

    A replacement reactor console was installed in 1977 at the W.S.U. 1 MW TRIGA-fueled reactor as the final step in an instrumentation upgrade program. The program was begun circa 1972 with the design, construction and installation of various systems and equipment. Major instruments were installed in the existing console and tested in the course of reactor operation. The culmination of the program was the installation of a cubicle designed and constructed to house the updated instrumentation. (author)

  16. Use of the TRIGA Reactor by the Radiochemistry Group of the Atominstitute of the Austrian Universities

    International Nuclear Information System (INIS)

    Bichler, M.; Buchtela, K.; Grass, F.; Ismail, S.

    1994-01-01

    The Radiochemistry Group of the Atominstitute of the Austrian Universities uses the TRIGA Mark II Reactor mainly for neutron activation analysis. Transport of samples to and from the irradiation positions in the reactor is performed by fast pneumatic transfer systems (transfer time 20 msec and 300 msec) and slow conventional transport facilities. Gamma-spectrometric instrumentation equipped with loss free counting systems is used to handle the high count rates up to 500 000 counts/sec. During the last years neutron activation analysis was applied to investigate environmental samples (soil, dust, incineration ash), geological samples (rocks, sediments, fossils, volcanic gases), biological materials (lichens, mushrooms and other plant materials, human diet, biological reference materials), raw materials (phosphate, coal) and archaeological materials (ancient glass). Lichen analysis was used for environmental monitoring. The content of some of the trace elements can be correlated with industrial activities, like manganese content with steel industry, the occurrence of vanadium and nickel with oil firing plants and stainless steel industry, selenium is found in lichen near coal firing plants. The amount of chlorine and sodium indicates the application of salt for road treatment during winter time, aluminum, scandium and hafnium content depends on the amount of dust in the environment. A further environmental application of neutron activation analysis is the determination of trace elements in volcanic gases. The halogens, arsenic, antimony, selenium, tellurium and mercury were determined and their daily output was calculated. The distribution of trace elements in fossils of known age gives us a geochemical key to condition and development of the paleo-environment. For this purpose we determined rare earth elements in 250 million years old microfossils (conodonts). Neutron activation analysis served also for some non scientific but nevertheless useful purposes: Organic

  17. Modeling a TRIGA Power System with ATHENA

    International Nuclear Information System (INIS)

    Davis, C.B.

    1985-01-01

    GA Technologies TRIGA Power System (TPS) is a power-producing version of the Training Research and Isotope General Atomic (TRIGA) reactor. The TPS analyzed here is designed to produce 10 MW of electrical power. The TPS features three major thermal-hydraulic systems, including a water-filled primary coolant system, a water-filled residual heat removal system, and a Freon-filled secondary coolant system. A thermal-hydraulic model of the TPS was developed using the Advanced Thermal Hydraulic Energy Network Analyzer (ATHENA) computer code, and two demonstration calculations were performed. ATHENA is based on the Reactor Excursion and Leak Analysis Program (RELAP5/MOD2) and has similar, but expanded capabilities. The expanded capabilities allow the representation of several different fluids, including water and Freon-11. This paper provides descriptions of the TPS, the ATHENA computer code and ATHENA TPS model, results of the demonstration calculations, conclusions, and references. 2 refs., 7 figs

  18. Thermal power calibrations of the IPR-R1 TRIGA reactor by the calorimetric and the heat balance methods

    International Nuclear Information System (INIS)

    Mesquita, Amir Zacarias; Rezende, Hugo Cesar; Souza, Rose Mary Gomes do Prado

    2009-01-01

    Since the first nuclear reactor was built, a number of methodological variations have been evolved for the calibration of the reactor thermal power. Power monitoring of reactors is done by means of neutronic instruments, but its calibration is always done by thermal procedures. The purpose of this paper is to present the results of the thermal power calibration carried out on March 5th, 2009 in the IPR-R1 TRIGA reactor. It was used two procedures: the calorimetric and heat balance methods. The calorimetric procedure was done with the reactor operating at a constant power, with primary cooling system switched off. The rate of temperature rise of the water was recorded. The reactor power is calculate as a function of the temperature-rise rate and the system heat capacity constant. The heat balance procedure consists in the steady-state energy balance of the primary cooling loop of the reactor. For this balance, the inlet and outlet temperatures and the water flow in the primary cooling loop were measured. The heat transferred through the primary loop was added to the heat leakage from the reactor pool. The calorimetric method calibration presented a large uncertainty. The main source of error was the determination of the heat content of the system, due to a large uncertainty in the volume of the water in the system and a lack of homogenization of the water temperature. The heat balance calibration in the primary loop is the standard procedure for calibrating the power of the IPR-R1 TRIGA nuclear reactor. (author))

  19. Immobilization of ion exchange radioactive resins of the TRIGA Mark III nuclear reactor; Inmovilizacion de resinas de intercambio ionico radiactivas del reactor nuclear Triga Mark III

    Energy Technology Data Exchange (ETDEWEB)

    Garcia M, H.; Emeterio H, M.; Canizal S, C. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, C.P. 11801 Mexico D.F. (Mexico)

    2000-07-01

    This work has the objective to develop the process and to define the agglutinating material which allows the immobilization of the ion exchange radioactive resins coming from the TRIGA Mark III nuclear reactor contaminated with Ba-133, Co-60, Cs-137, Eu-152, and Mn-54 through the behavior analysis of different immobilization agents such as: bitumens, cement and polyester resin. According to the International Standardization the archetype samples were observed with the following tests: determination of free liquid, leaching, charge resistance, biodegradation, irradiation, thermal cycle, burned resistance. Generally all the tests were satisfactorily achieved, for each agent. Therefore, the polyester resin could be considered as the main immobilizing. (Author)

  20. Implementation of the k{sub 0} technique using multi-detectors on diverse irradiation facilities of TRIGA Reactor; Implementacion de la tecnica k{sub 0} usando multidetectores en diferentes instalaciones de irradiacion del Reactor TRIGA

    Energy Technology Data Exchange (ETDEWEB)

    Caldera C, M. de G.

    2013-07-01

    The k{sub 0} method with the technique of neutron activation analysis allows obtaining important characteristics parameters that describe a nuclear reactor. Among these parameters are the form factor of epithermal neutron flux, α and the ratio of thermal neutron flux with respect to the epithermal neutron flux, f. These parameters were obtained by irradiation of two different monitors, one of Au-Zr and the other of Au-Mo-Cr, where the last one was made and implemented for the first time. Both monitors were irradiated in different positions in the TRIGA Mark III Reactor at the National Institute of Nuclear Research. (Author)

  1. IPR-R1 TRIGA research reactor decommissioning plan

    International Nuclear Information System (INIS)

    Andrade Grossi, Pablo; Oliveira de Tello, Cledola Cassia; Mesquita, Amir Zacarias

    2008-01-01

    The International Atomic Energy Agency (IAEA) is concerning to establish or adopt standards of safety for the protection of health, life and property in the development and application of nuclear energy for peaceful purposes. In this way the IAEA recommends that decommissioning planning should be part of all radioactive installation licensing process. There are over 200 research reactors that have either not operated for a considerable period of time and may never return to operation or, are close to permanent shutdown. Many countries do not have a decommissioning policy, and like Brazil not all installations have their decommissioning plan as part of the licensing documentation. Brazil is signatory of Joint Convention on the safety of spent fuel management and on the safety of radioactive waste management, but until now there is no decommissioning policy, and specifically for research reactor there is no decommissioning guidelines in the standards. The Nuclear Technology Development Centre (CDTN/CNEN) has a TRIGA Mark I Research Reactor IPR-R1 in operation for 47 years with 3.6% average fuel burn-up. The original power was 100 k W and it is being licensed for 250 k W, and it needs the decommissioning plan as part of the licensing requirements. In the paper it is presented the basis of decommissioning plan, an overview and the end state / final goal of decommissioning activities for the IPR-R1, and the Brazilian ongoing activities about this subject. (author)

  2. Technical report on natural evaporation system for radioactive liquid waste treatment arising from TRIGA research reactors' decontamination and decommissioning activities

    International Nuclear Information System (INIS)

    Moon, J. S.; Jung, K. J.; Baek, S. T.; Jung, U. S.; Park, S. K.; Jung, K. H.

    1999-01-01

    This technical report described that radioactive liquid waste treatment for dismantling/decontamination of TRIGA Mark research reactor in Seoul. That is, we try safety treatment of operation radioactive liquid waste during of operating TRIGA Mark research reactor and dismantling radioactive liquid waste during R and D of research reactor hereafter, and by utilizing of new natural evaporation facility with describing design criteria of new natural evaporation facility. Therefore, this technical report described the quantity of present radioactive liquid waste and dismantling radioactive liquid waste hereafter, analysis the status of radial-rays/radioactivity, and also treatment method of this radioactive liquid waste. Also, we derived the method that the safeguard of outskirts environment and the cost down of radioactive liquid waste treatment by minimize of the radioactive liquid waste quantities, through-out design/operation of new natural evaporation facility for treatment of operation radioactive liquid waste and dismantling radioactive liquid waste. (author). 6 refs., 12 tabs., 5 figs

  3. The evaluation of isotopic composition for TRIGA 14 MW spent fuel

    International Nuclear Information System (INIS)

    Covaci, St.; Toma, C.; Preda, M.

    2008-01-01

    In the summer of 1999 year, a first shipment of TRIGA HEU spent fuel to INEEL U.S.A. has taken place. he TRIGA HEU fuel was burned in the TRIGA steady state 14 MW reactor between 1980 and 1996 years. At the moment of prepared documentation for the shipment (July 1999), the evaluation of isotopic composition was calculated with ORIGEN-2 code with an irradiation history adequately prepared. Subsequently (May - June 2000), the evaluation was repeated with SAS2H module of SCALE 4.4a system. In the paper the results and the comparisons of the codes are presented, and the accuracy and convenient application of SCALE 4.4a system are emphasized. (authors)

  4. The characterization of a neutron radiography Triga reactor for NAA of chlorine in an iron oxide matrix

    International Nuclear Information System (INIS)

    Glagolenko, I.; Carney, K.; Difelici, R.; Maddison, D.; Sayer, M.; Hart, P.; Ross, J.; Kahn, S.; Swanson, R.

    2000-01-01

    An irradiation position in the 250 kW Triga reactor was characterized for instrumental neutron activation analysis of chlorine in an iron oxide matrix. Factors that affect the accuracy of the determination include variations in the reactor neutron spectrum and flux as a function of spatial position and the presence of chlorine impurities. Gold wire and foils were used to determine the neutron flux and cadmium ratio as a function of height in an air-filled irradiation tube. (author)

  5. Proceedings of 2. Yugoslav symposium on reactor physics, Part 2, Herceg Novi (Yugoslavia), 27-29 Sep 1966; 2. Jugoslovenski simpozijum iz reaktorske fizike, Deo 2, Herceg Novi (Yugoslavia), 27-29 Sep 1966

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1966-07-01

    This Volume 2 of the Proceedings of 2. Yugoslav symposium on reactor physics includes eight papers dealing with the following topics: method for measuring high anti reactivities of a reactor system; integration method for thermal reaction rate calculation; Determination of initial core configuration for BHWR-200 MWe; safety shutdowns and failures of the RA reactor equipment; determining the reactivity of absorption rods; measurements of thermal and fast neutron fluxes at the TRIGA reactor and other measurements during operation of the TRIGA reactor; mathematical modelling of the reactor safety; review of problems and methods for radiation risk assessment in the environment of a nuclear power plant.

  6. Piping Flexibility Analysis of the Primary Cooling System of TRIGA 2000 Bandung Reactor due to Earthquake

    International Nuclear Information System (INIS)

    Rahardjo, H.P.

    2011-01-01

    Earthquakes in a nuclear installation can overload a piping system which is not flexible enough. These loads can be forces, moments and stresses working on the pipes or equipment. If the load is too large and exceed the allowable limits, the piping and equipment can be damaged and lead to overall system operation failure. The load received by piping systems can be reduced by making adequate piping flexibility, so all the loads can be transmitted homogeneously throughout the pipe without load concentration at certain point. In this research the analysis of piping stress has been conducted to determine the size of loads that occurred in the piping of primary cooling system of TRIGA 2000 Reactor, Bandung if an earthquake happened in the reactor site. The analysis was performed using Caesar II software-based finite element method. The ASME code B31.1 arranging the design of piping systems for power generating system (Power Piping Code) was used as reference analysis method. Modeling of piping systems was based on the cooling piping that has already been installed and the existing data reported in Safety Analysis Reports (SARs) of TRIGA 2000 reactor, Bandung. The quake considered in this analysis is the earthquake that occurred due to the Lembang fault, since it has the Peak Ground Acceleration (PGA) in the Bandung TRIGA 2000 reactor site. The analysis results showed that in the static condition for sustain and expansion loads, the stress fraction in all piping lines does not exceed the allowable limit. However, during operation moment, in dynamic condition, the primary cooling system is less flexible at sustain load, expansion load, and combination load and the stress fraction have reached 95,5%. Therefore a pipeline modification (re-routing) is needed to make pipe stress does not exceed the allowable stress. The pipeline modification was carried out by applied a gap of 3 mm in the X direction of the support at node 25 and eliminate the support at the node 30, also a

  7. Computational analysis of Bangladesh 3 MW TRIGA research reactor using MCNP4C, JENDL-3.3 and ENDF/B-Vl data libraries

    International Nuclear Information System (INIS)

    Huda, M.Q.

    2006-01-01

    The three-dimensional continuous energy Monte Carlo code MCNP4C was used to develop a versatile and accurate full-core model of the 3 MW TRIGA MARK II research reactor at Atomic Energy Research Establishment, Savar, Dhaka, Bangladesh. The model represents in detail all components of the core with literally no physical approximation. All fresh fuel and control elements as well as the vicinity of the core were precisely described. Validation of the JENDL-3.3 and ENDF/BVI continuous energy cross-section data for MCNP4C was performed against some well-known benchmark lattices. For TRIGA analysis, data from JENDL-3.3 and ENDF/B-VI in combination with the JENDL-3.2 and ENDF/B-V data files (for nat Zr, nat Mo, nat Cr, nat Fe, nat Ni, nat Si, and nat Mg) at 300 K evaluations were used. Full S(α, β) scattering functions from ENDF/B-V for Zr in ZrH, H in ZrH and water molecule, and for graphite were used in both cases. The validation of the model was performed against the criticality and reactivity benchmark experiments of the TRIGA reactor. There is ∼20.0% decrease of thermal neutron flux occurs when the thermal library is removed during the calculation. Effect of erbium isotope that is present in the TRIGA fuel was also studied. In addition to the effective multiplication values, the well-known integral parameters: δ 28 , δ 25 , ρ 25 , and C * were calculated and compared for both JENDL3.3 and ENDF/B-VI libraries and were found to be in very good agreement. Results are also reported for most of the analyses performed by JENDL-3.2 and ENDF/B-V data libraries

  8. Some concept for the TRIGA core design

    International Nuclear Information System (INIS)

    Aizawa, Otohiko

    1994-01-01

    There is the research reactor called TRIGA Mark-2 of 100 kW in Atomic Energy Research Laboratory, Musashi Institute of Technology. Recently, while the various calculations on the core were carried out, the author became aware of that this TRIGA core was designed at that time with excellent consideration. The reason for that is, although fuel is arranged in simple concentric circular state at a glance, it was known that in reality, this is the modification of the hexagonal core of triangular lattice. In the examination of square lattice fuel arrangement, the reactivity was calculated by using the gap between fuel rods as the parameter and by using ENDF/B-4 library and Monte Carlo code Keno-5. It is known that the design of the lattice with maximum reactivity cannot be done by the square lattice. The similar examination was carried out on triangular lattice, and it was found that the gap between fuel rods of 4 mm is the optimal design. The average neutron energy spectra in the fuel rods of the TRIGA Mark-2 core agreed considerably well with the energy spectra at 4.16 cm fuel rod pitch in triangular hexagonal core. In the reactor of about 100 kW, even if the gap between fuel rods is less than 4 mm, heat removal is sufficiently possible. (K.I.)

  9. Real time monitoring system of the operation variables of the TRIGA IPR-R1 nuclear research reactor

    International Nuclear Information System (INIS)

    Ricardo, Carla Pereira; Mesquita, Amir Zacarias

    2007-01-01

    During the last two years all the operation parameters of the TRIGA IPR-R1 were monitored and real time indicated bu the data acquisition system developed for the reactor. All the information were stored on a rigid disk, at the collection system computer, leaving the information on the reactor performance and behaviour available for consultation in a chronological order. The data acquisition program has been updated and new reactor operation parameters were included for increasing the investigation and experiments possibilities. The register of reactor operation variables are important for the immediate or subsequent safety analyses for reporting the reactor operations to the external organizations. This data acquisition satisfy the IAEA recommendations. (author)

  10. Medical and radiobiological applications at the research reactor TRIGA Mainz

    International Nuclear Information System (INIS)

    Hampel, G.; Grunewald, C.; Kratz, J.-V.; Schmitz, T.; Schutz, C.; Werner, S.; Appelman, K.; Moss, R.; Blaickner, M.; Nawroth, T.; Otto, G.; Schmidberger, H.

    2010-01-01

    At the University of Mainz, Germany, a boron neutron capture therapy (BNCT) project has been started with the aim to expand and advance the research on the basis of the TAOrMINA protocol for the BNCT treatment of liver metastases of colorectal cancer. Irradiations take place at the TRIGA Mark II reactor. Biological and clinical research and surgery take place at the University and its hospital of Mainz. Both are situated in close vicinity to each other, which is an ideal situation for BNCT treatment, as similarly performed in Pavia, in 2001 and 2003. The application of BNCT to auto-transplanted organs requires development in the methodology, as well as regard to the irradiation facility and is part of the complex, interdisciplinary treatment process. The additional high surgical risk of auto-transplantation is only justified when a therapeutic benefit can be achieved. A BNCT protocol including explantation and conservation of the organ, neutron irradiation and re-implantation is logistically a very challenging task. Within the last years, research on all scientific, clinical and logistical aspects for the therapy has been performed. This includes work on computational modelling for the irradiation facility, tissue and blood analysis, radiation biology, dosimetry and surgery. Most recently, a clinical study on boron uptake in both healthy and tumour tissue of the liver and issues regarding dosimetry has been started, as well as a series of cell-biology experiments to obtain concrete results on the relative biological effectiveness (RBE) of ionizing radiation in liver tissue. (author)

  11. The Design of a Prompt Gamma Neutron Activation Analysis Beam for BNCT Purpose at the TRIGA Mark II Reactor in Pavia

    Energy Technology Data Exchange (ETDEWEB)

    Stella, S.; Bazani, A.; Ballarini, F.; Bortolussi, S.; Protti, N.; Altieri, S. [Department of Nuclear and Theoretical Physics, University of Pavia (Italy); Istituto Nazionale di Fisica Nucleare (INFN), Section of Pavia (Italy); Bruschi, P. [Department of Nuclear and Theoretical Physics, University of Pavia (Italy)

    2011-07-01

    In preclinical and clinical Boron Neutron Capture Therapy studies the knowledge of the amount of {sup 10}B in blood and tissues is very important. The boron concentration measurements method used in Pavia (Italy) is based on the charged particles spectrometry of thin tissue cuts irradiated in the Thermal Column of the TRIGA reactor of the University. In order to perform measurements in biological liquids such as blood and urine, or in other tissue that cannot be cut in slices, a Prompt Gamma Neutron Activation Analysis (PGNAA) facility is being designed, which measures {sup 10}B concentration detecting the prompt gamma from boron nuclear capture reaction. At the TRIGA reactor in Pavia, there are four horizontal channels, potentially available for PGNAA. The choice of the suitable channel, and the design of its configuration, were achieved using the Monte Carlo neutron transport code MCNP4c2. To perform the simulations, an input code already validated, describing the reactor structure and the neutron source, was used. The calculations were implemented applying non-analog techniques for the neutron transport, that are necessary to obtain a sufficient statistic in every positions along the channel and especially at its end. The selection of the channel for PGNAA installation was carried out by comparing the simulated fluxes obtained in the different channels at the present configuration. The channel shielded by the core reflector was chosen, because the graphite lowers the fast component of the neutrons, with no need to insert additional material in the facility. The thermal flux at its end is 1.7 x 10{sup 8} n/cm{sup 2} s with thermal-to-total neutron flux ratio around 0.8. Subsequently a bismuth block for gamma radiation shielding and blocks of single crystal sapphire as filter for fast neutron component were inserted in the channel. Other components of the facility that are under study are a collimator and the beam catcher. (author)

  12. Development of the user interface for visualization of the auxiliary systems of the TRIGA Mark III nuclear reactor; Desarrollo de la interface de usuario para la visualizacion de los sistemas auxiliares del reactor nuclear Triga Mark III

    Energy Technology Data Exchange (ETDEWEB)

    Merced D, J. E.

    2016-07-01

    The Instituto Nacional de Investigaciones Nucleares (ININ) has a nuclear research reactor type swimming pool with movable core cooled and moderate with light water. The nominal maximum power of the reactor is 1 MW in steady-state operation and can be pulsed at a maximum power of 2,000 MW for approximately 10 milliseconds. This reactor is mainly used to study the effects of radiation on various materials and substances. In 2001 the new control console of the nuclear reactor was installed which was based on two digital computers, one computer controls the bar management mechanisms and the other the systems to the reactor operator. In 2004, the control computer was replaced and the software was updated. Within the modernization and/or updating of the TRIGA Mark III reactor of ININ, is intended (theme of this work) to develop the user interface for the visualization of the auxiliary systems, through a Man-Machine Interface module for the renewal process of the control console. The man-machine interface system to be developed will have communication with the programmable logic controllers that will be constantly monitored and controlled to obtain real-time variables of the reactor behavior. (Author)

  13. United States Domestic Research Reactor Infrastructure TRIGA Reactor Fuel Support

    International Nuclear Information System (INIS)

    Morrell, Douglas

    2011-01-01

    The United State Domestic Research Reactor Infrastructure Program at the Idaho National Laboratory manages and provides project management, technical, quality engineering, quality inspection and nuclear material support for the United States Department of Energy sponsored University Reactor Fuels Program. This program provides fresh, unirradiated nuclear fuel to Domestic University Research Reactor Facilities and is responsible for the return of the DOE-owned, irradiated nuclear fuel over the life of the program. This presentation will introduce the program management team, the universities supported by the program, the status of the program and focus on the return process of irradiated nuclear fuel for long term storage at DOE managed receipt facilities. It will include lessons learned from research reactor facilities that have successfully shipped spent fuel elements to DOE receipt facilities.

  14. Nuclear waste management plan of the Finnish TRIGA reactor

    International Nuclear Information System (INIS)

    Salmenhaara, S.E.J. . Author

    2004-01-01

    The FiR 1 - reactor, a 250 kW Triga reactor, has been in operation since 1962. The main purpose to run the reactor is now the Boron Neutron Capture Therapy (BNCT). The BNCT work dominates the current utilization of the reactor. The weekly schedule allows still one or two days for other purposes such as isotope production and neutron activation analysis. According to the Finnish legislation the research reactor must have a nuclear waste management plan. The plan describes the methods, the schedule and the cost estimate of the whole decommissioning waste and spent fuel management procedure starting from the removal of the spent fuel, the dismantling of the reactor and ending to the final disposal of the nuclear wastes. The cost estimate of the nuclear waste management plan has to be updated annually and every fifth year the plan will be updated completely. According to the current operating license of our reactor we have to achieve a binding agreement, in 2005 at the latest, between our Research Centre and the domestic nuclear power companies about the possibility to use the Olkiluoto final disposal facility for our spent fuel. There is also the possibility to make the agreement with USDOE about the return of our spent fuel back to USA. If we want, however, to continue the reactor operation beyond the year 2006, the domestic final disposal is the only possibility. In Finland the producer of nuclear waste is fully responsible for its nuclear waste management. The financial provisions for all nuclear waste management have been arranged through the State Nuclear Waste Management Fund. The main objective of the system is that at any time there shall be sufficient funds available to take care of the nuclear waste management measures caused by the waste produced up to that time. The system is applied also to the government institutions like FiR 1 research reactor. (author)

  15. TRIGA update and modification

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, G W; Seale, R L [University of Arizona (United States)

    1974-07-01

    The TRIGA originally installed at the University of Arizona in 1958 has been extensively modified. A Mark III console, rack-and-pinion regulating and shim control rods equipped with fuel-followers, a pneumatic transient rod, and a modern bridge structure were installed. The original 63 aluminum-clad fuel elements were shipped to the University of Utah in Salt Lake City and 85 partially used stainless-steel clad fuel elements were obtained from General Atomic in San Diego. The transfer and remodelling operation are summarized. A little more than one year of operation following these changes has been completed. Several instrumentation problems have been encountered and will be reported. The calibration of the partially spent fuel elements has been used to generate independent evaluations of prior fuel burnup. Finally, the utility of the reactor facility has been increased by adding a neutron radiography capability and a delayed neutron uranium assay system. (author)

  16. Refurbishment of the Oregon State University rotating rack

    International Nuclear Information System (INIS)

    Higginbotham, J.F.

    1991-01-01

    TRIGA reactors have experienced operational difficulties with the rotating racks used for sample irradiation. The most common problem occurs when the rack seizes, and the corrective action taken is replacement of the rack assembly. This paper describes the symptoms leading to rack failure and a refurbishment procedure to correct the problem without replacing the rack at the Oregon State University TRIGA Reactor (OSTR) Facility. This procedure was accomplished with extraordinary results from an operational and a radiation protection standpoint. The refurbishment has extended the useful life of this reactor facility with minimal financial impact. Given the declining number of university-based research reactors, it is in the nation's best interest to maintain the currently operating research reactor facilities, and the described procedure can aid in achieving that goal

  17. TRIGA Mark II Ljubljana - spent fuel transportation

    International Nuclear Information System (INIS)

    Ravnik, M.; Dimic, V.

    2008-01-01

    The most important activity in 1999 was shipment of the spent fuel elements back to the United States for final disposal. This activity started already in 1998 with some governmental support. In July 1999 all spent fuel elements (219 pieces) from the TRIGA research reactor in Ljubljana were shipped back to the United Stated by the ship from the port Koper in Slovenia. At the same time shipment of the spent fuel from the research reactor in Pitesti, Romania, and the research reactor in Rome, Italy, was conducted. During the loading the radiation exposure to the workers was rather low. The loading and shipment of the spent nuclear fuel went very smoothly and according the accepted time table. During the last two years the TRIGA research reactor in Ljubljana has been in operation about 1100 hours per year and without any undesired shut-down. (authors)

  18. Neuro-diffuse algorithm for neutronic power identification of TRIGA Mark III reactor; Algoritmo neuro-difuso para la identificacion de la potencia neutronica del reactor Triga Mark III

    Energy Technology Data Exchange (ETDEWEB)

    Rojas R, E.; Benitez R, J. S. [Instituto Tecnologico de Toluca, Division de Estudios de Posgrado e Investigacion, Av. Tecnologico s/n, Ex-Rancho La Virgen, 50140 Metepec, Estado de Mexico (Mexico); Segovia de los Rios, J. A.; Rivero G, T. [ININ, Gerencia de Ciencias Aplicadas, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)], e-mail: jorge.benitez@inin.gob.mx

    2009-10-15

    In this work are presented the results of design and implementation of an algorithm based on diffuse logic systems and neural networks like method of neutronic power identification of TRIGA Mark III reactor. This algorithm uses the punctual kinetics equation as data generator of training, a cost function and a learning stage based on the descending gradient algorithm allow to optimize the parameters of membership functions of a diffuse system. Also, a series of criteria like part of the initial conditions of training algorithm are established. These criteria according to the carried out simulations show a quick convergence of neutronic power estimated from the first iterations. (Author)

  19. SANS facility at the Pitesti 14 MW Triga reactor

    International Nuclear Information System (INIS)

    Ionita, I.; Anghel, E.; Mincu, M.; Datcu, A.; Grabcev, B.; Todireanu, S.; Constantin, F.; Shvetsov, V.; Popescu, G.

    2006-01-01

    Full text of publication follows: At the present time, an important not yet fully exploited potentiality is represented by the SANS instruments existent at lower power reactors and reactors in developing countries even if they are, generally, endowed with a simpler equipment and are characterized by the lack of infrastructure to maintain and repair high technology accessories. The application of SANS at lower power reactors and in developing countries nevertheless is possible in well selected topics where only a restricted Q range is required, when scattering power is expected to be sufficiently high or when the sample size can be increased at the expense of resolution. Examples of this type of applications are: 1) Phase separation and precipitates in material science, 2) Ultrafine grained materials (nano-crystals, ceramics), 3) Porous materials such as concretes and filter materials, 4) Conformation and entanglements of polymer-chains, 5) Aggregates of micelles in microemulsions, gels and colloids, 6) Radiation damage in steels and alloys. The need for the installation of a new SANS facility at the Triga Reactor of the Institute of Nuclear Researches in Pitesti, Romania become actual especially after the shutting down of the VVRS Reactor from Bucharest. A monochromatic neutron beam with 1.5 Angstrom ≤ λ ≤ 5 Angstrom is produced by a mechanical velocity selector with helical slots.The distance between sample and detectors plane is (5.2 m ). The sample width may be fixed between 10 mm and 20 mm. The minimum value of the scattering vector is Q min = 0.005 Angstrom -1 while the maximal value is Q max = 0.5 Angstrom -1 . The relative error is ΔQ/Q min = 0.5. The cooperation partnership between advanced research centers and the smaller ones from developing countries could be fruitful. The formers act as mentors in solving specific problems. Such a partnership was established between INR Pitesti, Romania and JINR Dubna, Russia. The first step in this cooperation

  20. Environmental radiation monitoring from the decommission of TRIGA

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Geun Sik; Lee, Chang Woo

    2000-03-01

    Environmental radiation monitoring was carried out with measurement of environmental radiation and environmental radioactivity analysis around TRIGA Research Reactor. The results of environmental radiation monitoring around TRIGA Research Reactor are the follows: The average level of environmental radiation measured by potable ERM and accumulated radiation dose by TLD was almost same level compared with thepast years. Gross {beta} radioactivity in environmental samples showed a environmental level. {gamma}-radionuclides in water samples were not detected. but only radionuclide K-40, which is natural radionuclide, was detected in the all samples and Cs-137 was detected in the surface soil and discharge sediment. (author)

  1. Independent Confirmatory Survey Report for the University of Arizona Nuclear Reactor Laboratory, Tucson, Arizona DCN:2051-SR-01-0

    International Nuclear Information System (INIS)

    Altic, Nick A.

    2011-01-01

    The University of Arizona (University) research reactor is a TRIGA swimming pool type reactor designed by General Atomics and constructed at the University in 1958. The reactor first went into operation in December of 1958 under U.S. Nuclear Regulatory Commission (NRC) license R-52 until final shut down on May 18, 2010. Initial site characterization activities were conducted in February 2009 during ongoing reactor operations to assess the radiological status of the Nuclear Reactor Laboratory (NRL) excluding the reactor tank, associated components, and operating systems. Additional post-shutdown characterization activities were performed to complete characterization activities as well as verify assumptions made in the Decommissioning Plan (DP) that were based on a separate activation analysis (ESI 2009 and WMG 2009). Final status survey (FSS) activities began shortly after the issuance of the FSS plan in May 2011. The contractor completed measurement and sampling activities during the week of August 29, 2011.

  2. Data acquisition system for the 3 MW TRIGA reactor at AERE Savar

    International Nuclear Information System (INIS)

    Abudl Ahad, A.O.M.

    1998-01-01

    A 3 MW TRIGA Mark II research reactor control console has been studied in detail and the channels have been selected for monitoring, display and record using the microcomputer. Information from these channels are fed to the computer through hardware like buffer, AD converter, multiplexer, etc. for continues display and permanent records using video monitor, printer and diskettes. Besides, the information from the console, other information like operating time, power, total burnup of fuel, operating persons, etc. are also available, with very little modifications in both hardware and software, the data logging system is now running successfully. (author)

  3. Computational analysis of the dose rates at JSI TRIGA reactor irradiation facilities.

    Science.gov (United States)

    Ambrožič, K; Žerovnik, G; Snoj, L

    2017-12-01

    The JSI TRIGA Mark II, IJS research reactor is equipped with numerous irradiation positions, where samples can be irradiated by neutrons and γ-rays. Irradiation position selection is based on its properties, such as physical size and accessibility, as well as neutron and γ-ray spectra, flux and dose intensities. This paper presents an overview on the neutron and γ-ray fluxes, spectra and dose intensities calculations using Monte Carlo MCNP software and ENDF/B-VII.0 nuclear data libraries. The dose-rates are presented in terms of ambient dose equivalents, air kerma, and silicon dose equivalent. At full reactor power the neutron ambient dose equivalent ranges from 5.5×10 3 Svh -1 to 6×10 6 Svh -1 , silicon dose equivalent from 6×10 2 Gy/h si to 3×10 5 Gy/h si , and neutron air kerma from 4.3×10 3 Gyh -1 to 2×10 5 Gyh -1 . Ratio of fast (1MeVreactor power from 3.4×10 3 Svh -1 to 3.6×10 5 Svh -1 and γ air kerma range 3.1×10 3 Gyh -1 to 2.9×10 5 Gyh -1 . Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Operation experience and maintenance at the TRIGA Mark II L.E.N.A. reactor

    International Nuclear Information System (INIS)

    Gngoli, F.; Berzero, A.; Lana, F.; Rosti, G.; Meloni, S.

    2008-01-01

    The TRIGA Mark II reactor of the University of Pavia was operated in the last two years on a routine basis, mostly for neutron activation analysis purposes. Moreover the reactor was completely shutdown in the first six months of this year to allow the dismantling of the NADIR experimental setup. The paper presents: - Reactor operation from July 1990 to June 1992; - Reactor users in the time period January 1990 - December 1991; - Specific activities of some radionuclides in the filling materials; - Specific activity of some radionuclides in thermal column materials. Operations related to dismantling of NADIR experimental facility are described. Finally the new thermal column configuration is presented. Starting from the end inside the reactor tank, a graphite layer (35 cm thick) was positioned, followed by a bismuth layer (10 cm thick) to reduce gamma-ray intensity. The old graphite rods were then positioned leaving in the central part, on the equatorial plane of the thermal column, a cavity whose vertical section has 40 cm width and 20 cm height. The bottom of the cavity, towards to the reactor tank, has been lined with additional layers of graphite (10 cm), bismuth (10 cm) and again graphite (1 cm). The new configuration allowed new experiments to be performed. The cavity in the central part has been created to allow the irradiation of large biological samples such as experimental animal and human livers. This is a peculiar step in a neutron capture boron therapy project to be carried out at the University of Pavia. In order to avoid an implemented 41 Ar production in the void space between shutters and the thermal column outer end, the external surface of the thermal column has been coated with boral sheets. The neutron flux profile, both thermal and epithermal, and cadmium ratio for gold are shown. The flux distribution appears to be adequate to proceed with the neutron capture boron therapy experiment. The LENA Health Physics Service has checked all phases of

  5. Adaptive fuzzy control of neutron power of the TRIGA Mark III reactor; Control difuso adaptable de la potencia neutronica del reactor Triga Mark III

    Energy Technology Data Exchange (ETDEWEB)

    Rojas R, E.

    2014-07-01

    The design and implementation of an identification and control scheme of the TRIGA Mark III research nuclear reactor of the Instituto Nacional de Investigaciones Nucleares (ININ) of Mexico is presented in this thesis work. The identification of the reactor dynamics is carried out using fuzzy logic based systems, in which a learning process permits the adjustment of the membership function parameters by means of techniques based on neural networks and bio-inspired algorithms. The resulting identification system is a useful tool that allows the emulation of the reactor power behavior when different types of insertions of reactivity are applied into the core. The identification of the power can also be used for the tuning of the parameters of a control system. On the other hand, the regulation of the reactor power is carried out by means of an adaptive and stable fuzzy control scheme. The control law is derived using the input-output linearization technique, which permits the introduction of a desired power profile for the plant to follow asymptotically. This characteristic is suitable for managing the ascent of power from an initial level n{sub o} up to a predetermined final level n{sub f}. During the increase of power, a constraint related to the rate of change in power is considered by the control scheme, thus minimizing the occurrence of a safety reactor shutdown due to a low reactor period value. Furthermore, the theory of stability in the sense of Lyapunov is used to obtain a supervisory control law which maintains the power error within a tolerance region, thus guaranteeing the stability of the power of the closed loop system. (Author)

  6. Modernization of the facilities of the TRIGA Mark III reactor of ININ; Modernizacion de las instalaciones del reactor TRIGA Mark III del ININ

    Energy Technology Data Exchange (ETDEWEB)

    Mendez T, D.; Flores C, J., E-mail: dario.mendez@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2016-09-15

    The TRIGA Mark III reactor of the Instituto Nacional de Investigaciones Nucleares (ININ) has been in operation since 1968 under strict maintenance and component replacement programs, which has allowed its safe operation during this time. Under this scheme, the reactor was operating under suitable conditions, taking into account the different requests for operation that were received for the samples irradiation for the radioisotopes production such as the Sm-153, personnel training, basic research, archaeology and environmental studies and nuclear chemistry of the elements. However, a modernization program of its components and laboratories was required, in order to improve safety in the operation of the same and to increase its use in the analysis of samples by neutron activation and in the training of personnel. This program known as Modernization Program of the Reactor Facilities, was proposed alongside the project to replace high-enrichment fuels with low-enrichment fuels at the end of 2011 and early 2012. The central aspects of this program are described in this work, grouped into generic topics that include instrumentation and control, the radiological monitoring system of the area, the cooling system, the ventilation system, the neutron activation analysis laboratory, the manufacture of graphite elements, inspection submersible system of the pool, temporary storage system for irradiated fuels, traveling crane, Reactor support laboratories and technical meetings, courses and seminars for reactor personnel and associated groups. It also describes some of the most relevant components required for each system and the progress that is made in each one of them. As a fundamental result of the implementation of this Modernization Program of the Reactor Facilities, there has been a substantial improvement in the performance of the systems and components of its facilities, in the reliability of its operation and in the safety of the same. (Author)

  7. Assessment of Power Quality Problems for TRIGA PUSPATI Reactor (RTP)

    International Nuclear Information System (INIS)

    Mohd Fazli Zakaria; Ramachandaramurthy, V.K.

    2016-01-01

    The electrical power systems are exposed to different types of power quality disturbances. Investigation and monitoring of power quality is necessary to maintain accurate operation of sensitive equipment especially for nuclear installations. This paper will discuss the power quality problems observed at the electrical sources of PUSPATI TRIGA Reactor (RTP). Assessment of power quality requires the identification of any anomalous behavior on a power system, which adversely affects the normal operation of electrical or electronic equipment. A power quality assessment involves gathering data resources; analyzing the data (with reference to power quality standards) then, if problems exist, recommendation of mitigation techniques must be considered. Field power quality data is collected by power quality recorder and analyzed with reference to power quality standards. Normally the electrical power is supplied to the RTP via two sources in order to keep a good reliability where each of them is designed to carry the full load. The assessment of power quality during reactor operation was performed for both electrical sources. There were several disturbances such as voltage harmonics and flicker that exceeded the thresholds. (author)

  8. Conceptual design of reactor TRIGA PUSPATI (RTP) spent fuel storage rack

    International Nuclear Information System (INIS)

    Tonny Lanyau; Mohd Fazli Zakaria; Zaredah Hashim; Ahmad Nabil Ab Rahim; Mohammad Suhaimi Kassim

    2010-01-01

    PUSPATI TRIGA Reactor (RTP) is a pool type research reactor with 1MW thermal power. It has been safely operated since 28 June 1982. During 28 years of safe operation, there are several systems and components of the RTP that have been maintained, repaired, upgraded and replaced in order to maintain its function and safety conditions. RTP has been proposed to be upgraded so that optimum operation of RTP could be achieved as well as fulfill the future needs. Thus, competencies and technical capabilities were needed to design and develop the reactor system. In the meantime, there is system or component need to be maintained such as fuel elements. Since early operation, most of the fuel elements still can be used and none of the fuel elements was replaced or sent for reprocessing and final disposal. Towards the power upgrading, preparation of spent fuel storage is needed for temporary storing of the fuels discharged from the reactor core. The spent fuel storage rack will be located in the spent fuel pool to accommodate the spent fuels before it is send to reprocessing or final disposal. This paper proposes the conceptual design of the spent fuel storage rack. The output of this paper focused on the physical and engineering design of the spent fuel storage. (author)

  9. Refurbishment of the Primary Cooling System of the Puspati Triga Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Ramli, S.; Zakaria, M. F.; Masood, Z. [Malaysian Nuclear Agency, Kajang (Malaysia)

    2014-08-15

    The refurbishment of the 27 year old primary cooling system of the 1 MW PUSPATI TRIGA reactor was completed in April 2010 over an eight month outage. The project was implemented with the dual objective of meeting current user needs as well as a future reactor core power upgrade. Hence the cooling system was partly modernized to cater for a 3 MW{sub th} reactor by installing higher capacity heat exchangers and pumps while maintaining the piping and valve sizes. The old 1 MW tube and shell heat exchanger, which had lost 25% of its heat exchange capacity, was replaced with two 1.5 MW plate type heat exchangers. Several manually operated valves were replaced with motorized units to allow remote operation from the control room. The installed cooling system was flushed with distilled water and then subjected to hydrostatic pressure tests. In the cold run test, the system was operated for an hour for every pump and heat exchanger combination while all operating parameters were checked. In the hot run test, the same was done at four levels of increasing reactor power, and dose measurements were also recorded. The paper gives the design, installation, testing and commissioning details of the project. (author)

  10. Measurements of neutron flux distributions in the core of the Ljubljana TRIGA Mark II Reactor

    International Nuclear Information System (INIS)

    Rant, J.; Ravnik, M.; Mele, I.; Dimic, V.

    2008-01-01

    Recently the Ljubljana TRIGA Mark II Reactor has been refurbished and upgraded to pulsed operation. To verify the core design calculations using TRIGAP and PULSTR1 codes and to obtain necessary data for future irradiation and neutron beam experiments, an extensive experimental program of neutron flux mapping and neutron field characterization was carried out. Using the existing neutron measuring thimbles complete axial and radial distributions in two radial directions were determined for two different core configurations. For one core configuration the measurements were also carried out in the pulsed mode. For flux distributions thin Cu (relative measurements) and diluted Au wires (absolute values) were used. For each radial position the cadmium ratio was determined in two axial levels. The core configuration was rather uniform, well defined (fresh fuel of a single type, including fuelled followers) and compact (no irradiation channels or gaps), offering unique opportunity to test the computer codes for TRIGA reactor calculations. The neutron flux measuring procedures and techniques are described and the experimental results are presented. The agreement between the predicted and measured power peaking factors are within the error limits of the measurements (<±5%) and calculations (±10%). Power peaking occurs in the B ring, and in the A ring (centre) there is a significant flux depression. (authors)

  11. Retrofitting the instrumentation and control system of primary cooling circuit from TRIGA INR 14 MW reactor

    International Nuclear Information System (INIS)

    Preda, M.; Ciocanescu, M.; Ana, E. M.; Cristea, D.

    2008-01-01

    Activities of retrofitting the instrumentation and control system from TRIGA INR primary cooling circuit consists in replacement of actual system for: - parameter measurement; - safety; - reactor external scramming; - protection, command and supply for electrical elements of the system. This retrofitting project is designed to ensure the necessary features of reactor external safety and for technological parameter measurement. The new safety system of main cooling circuit is completely separated from its operating system and is arranged in a panel assembly in reactor control room. The operating system has the following features: - data acquisition; - parameter value and state of command elements displaying; - command elements on hierarchical levels; - operator information through visual and acoustic alarm. (authors)

  12. Homogeneous SLOWPOKE reactors for replacing SLOWPOKE-2 research reactors and the production of radioisotopes

    International Nuclear Information System (INIS)

    Bonin, H.W.; Hilborn, J.W.; Carlin, G.E.; Gagnon, R.; Busatta, P.

    2014-01-01

    Inspired from the inherently safe SLOWPOKE-2 research reactor, the Homogeneous SLOWPOKE reactor was conceived with a double goal: replacing the heterogeneous SLOWPOKE-2 reactors when they reach end-of-core life to continue their missions of neutron activation analysis and neutron radiography at universities, and to produce radioisotopes such as 99 Mo for medical applications. A homogeneous reactor core allows a much simpler extraction of radioisotopes (such as 99 Mo) for applications in industry and nuclear medicine. The 20 kW Homogeneous SLOWPOKE reactor was modelled using both the deterministic WIMS-AECL and the probabilistic MCNP 5 reactor simulation codes. The homogeneous fuel mixture was a dilute aqueous solution of Uranyl Sulfate (UO 2 SO 4 ) with 994.2 g of 235 U (enrichment at 20%) providing an excess reactivity at operating temperature (40 o C) of 3.8 mk for a molality determined as 1.46 mol kg -1 for a Zircaloy-2 reactor vessel. Because this reactor is intended to replace the core of SLOWPOKE-2 reactors, the Homogeneous SLOWPOKE reactor core had a height about twice its diameter. The reactor could be controlled by mechanical absorber rods in the beryllium reflector, chemical control in the core, or a combination of both. The safety of the Homogeneous SLOWPOKE reactor was analysed for both normal operation and transient conditions. Thermal-hydraulics calculations used COMSOL Multiphysics and the results showed that natural convection was sufficient to ensure adequate reactor cooling in all situations. The most severe transient simulated resulted from a 5.87 mk step positive reactivity insertion to the reactor in operation at critical and at steady state at 20 o C. Peak temperature and power were determined as 83 o C and 546 kW, respectively, reached 5.1 s after the reactivity insertion. However, the power fell rapidly to values below 20 kW some 35 s after the peak and remained below that value thereafter. Both the temperature and void coefficients are

  13. Homogeneous SLOWPOKE reactors for replacing SLOWPOKE-2 research reactors and the production of radioisotopes

    Energy Technology Data Exchange (ETDEWEB)

    Bonin, H.W., E-mail: bonin-h@rmc.ca [Royal Military College of Canada, Kingston, Ontario (Canada); Hilborn, J.W. [Canadian Nuclear Laboratories, Chalk River, Ontario (Canada); Carlin, G.E. [Ontario Power Generation, Toronto, Ontario (Canada); Gagnon, R.; Busatta, P. [Canadian Forces (Canada)

    2014-07-01

    Inspired from the inherently safe SLOWPOKE-2 research reactor, the Homogeneous SLOWPOKE reactor was conceived with a double goal: replacing the heterogeneous SLOWPOKE-2 reactors when they reach end-of-core life to continue their missions of neutron activation analysis and neutron radiography at universities, and to produce radioisotopes such as {sup 99}Mo for medical applications. A homogeneous reactor core allows a much simpler extraction of radioisotopes (such as {sup 99}Mo) for applications in industry and nuclear medicine. The 20 kW Homogeneous SLOWPOKE reactor was modelled using both the deterministic WIMS-AECL and the probabilistic MCNP 5 reactor simulation codes. The homogeneous fuel mixture was a dilute aqueous solution of Uranyl Sulfate (UO{sub 2}SO{sub 4}) with 994.2 g of {sup 235}U (enrichment at 20%) providing an excess reactivity at operating temperature (40 {sup o}C) of 3.8 mk for a molality determined as 1.46 mol kg{sup -1} for a Zircaloy-2 reactor vessel. Because this reactor is intended to replace the core of SLOWPOKE-2 reactors, the Homogeneous SLOWPOKE reactor core had a height about twice its diameter. The reactor could be controlled by mechanical absorber rods in the beryllium reflector, chemical control in the core, or a combination of both. The safety of the Homogeneous SLOWPOKE reactor was analysed for both normal operation and transient conditions. Thermal-hydraulics calculations used COMSOL Multiphysics and the results showed that natural convection was sufficient to ensure adequate reactor cooling in all situations. The most severe transient simulated resulted from a 5.87 mk step positive reactivity insertion to the reactor in operation at critical and at steady state at 20 {sup o}C. Peak temperature and power were determined as 83 {sup o}C and 546 kW, respectively, reached 5.1 s after the reactivity insertion. However, the power fell rapidly to values below 20 kW some 35 s after the peak and remained below that value thereafter. Both the

  14. Radioactivity of spent TRIGA fuel

    International Nuclear Information System (INIS)

    Usang, M. D.; Nabil, A. R. A.; Alfred, S. L.; Hamzah, N. S.; Abi, M. J. B.; Rawi, M. Z. M.; Abu, M. P.

    2015-01-01

    Some of the oldest TRIGA fuel in the Malaysian Reaktor TRIGA PUSPATI (RTP) is approaching the limit of its end of life with burn-up of around 20%. Hence it is prudent for us to start planning on the replacement of the fuel in the reactor and other derivative activities associated with it. In this regard, we need to understand all of the risk associated with such operation and one of them is to predict the radioactivity of the fuel, so as to estimate the safety of our working conditions. The radioactivity of several fuels are measured and compared with simulation results to confirm the burnup levels of the selected fuels. The radioactivity measurement are conducted inside the water tank to reduce the risk of exposure and in this case the detector wrapped in plastics are lowered under water. In nuclear power plant, the general practice was to continuously burn the fuel. In research reactor, most operations are based on the immediate needs of the reactor and our RTP for example operate periodically. By integrating the burnup contribution for each core configuration, we simplify the simulation of burn up for each core configuration. Our results for two (2) fuel however indicates that the dose from simulation underestimate the actual dose from our measurements. Several postulates are investigated but the underlying reason remain inconclusive

  15. Radioactivity of spent TRIGA fuel

    Energy Technology Data Exchange (ETDEWEB)

    Usang, M. D., E-mail: mark-dennis@nuclearmalaysia.gov.my; Nabil, A. R. A.; Alfred, S. L.; Hamzah, N. S.; Abi, M. J. B.; Rawi, M. Z. M.; Abu, M. P. [Reactor Department, Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor (Malaysia)

    2015-04-29

    Some of the oldest TRIGA fuel in the Malaysian Reaktor TRIGA PUSPATI (RTP) is approaching the limit of its end of life with burn-up of around 20%. Hence it is prudent for us to start planning on the replacement of the fuel in the reactor and other derivative activities associated with it. In this regard, we need to understand all of the risk associated with such operation and one of them is to predict the radioactivity of the fuel, so as to estimate the safety of our working conditions. The radioactivity of several fuels are measured and compared with simulation results to confirm the burnup levels of the selected fuels. The radioactivity measurement are conducted inside the water tank to reduce the risk of exposure and in this case the detector wrapped in plastics are lowered under water. In nuclear power plant, the general practice was to continuously burn the fuel. In research reactor, most operations are based on the immediate needs of the reactor and our RTP for example operate periodically. By integrating the burnup contribution for each core configuration, we simplify the simulation of burn up for each core configuration. Our results for two (2) fuel however indicates that the dose from simulation underestimate the actual dose from our measurements. Several postulates are investigated but the underlying reason remain inconclusive.

  16. Development of a simulator for design and test of power controllers in a TRIGA Mark III reactor; Desarrollo de un simulador para diseno y prueba de controladores de potencia en un reactor TRIGA Mark III

    Energy Technology Data Exchange (ETDEWEB)

    Perez M, C.; Benitez R, J.S.; Lopez C, R. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2003-07-01

    The development of a simulator that uses the Runge-Kutta-Fehlberg method to solve the model of the punctual kinetics of a nuclear research reactor type TRIGA. The simulator includes an algorithm of power control of the reactor based on the fuzzy logic, a friendly graphic interface which responds to the different user's petitions and that it shows numerical and graphically the results in real time. The user can modify the demanded power and to visualize the dynamic behavior of the one system. This simulator was developed in Visual Basic under an open architecture with which its will be prove different controllers for its analysis. (Author)

  17. Thermal spectra of the TRIGA Mark III reactor; El espectro termico del reactor TRIGA Mark III

    Energy Technology Data Exchange (ETDEWEB)

    Macias B, L.R.; Palacios G, J. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1998-07-01

    The diffraction phenomenon is gave in observance of the well known Bragg law in crystalline materials and this can be performance by mean of X-rays, electrons and neutrons among others, which allows to do inside the field of each one of these techniques the obtaining of measurements focussed at each one of them. For the present work, it will be mentioned only the referring to X-ray and neutron techniques. The X-ray diffraction due to its properties just it does measurements which are known in general as superficial measurements of the sample material but for the properties of the neutrons, this diffraction it explores in volumetric form the sample material. Since the neutron diffraction process depends lots of its intensity, then it is important to know the neutron source spectra that in this case is supplied by the TRIGA Mark III reactor. Within of diffraction techniques a great number of them can be found, however some of the traditional will be mentioned such as the identification of crystalline samples, phases identification and the textures measurement. At present this last technique is founded on the dot of a minimum error and the technique of phases identification performs but not compete with that which is obtained by mean of X-rays due to this last one has a major resolution. (Author)

  18. Implementation of the k0 technique using multi-detectors on diverse irradiation facilities of TRIGA Reactor

    International Nuclear Information System (INIS)

    Caldera C, M. de G.

    2013-01-01

    The k 0 method with the technique of neutron activation analysis allows obtaining important characteristics parameters that describe a nuclear reactor. Among these parameters are the form factor of epithermal neutron flux, α and the ratio of thermal neutron flux with respect to the epithermal neutron flux, f. These parameters were obtained by irradiation of two different monitors, one of Au-Zr and the other of Au-Mo-Cr, where the last one was made and implemented for the first time. Both monitors were irradiated in different positions in the TRIGA Mark III Reactor at the National Institute of Nuclear Research. (Author)

  19. Study on external dose around the Reactor TRIGA PUSPATI (RTP) Facility: A proposal

    International Nuclear Information System (INIS)

    Hairul Nizam Idris

    2012-01-01

    In order to meet the requirement of the recent regulation (AELB-BSRP 2010), it is absolutely necessary to re-execute the in-situ and accumulated external dose assessment at the surrounding area of the Reactor TRIGA PUSPATI (RTP) facility. A number of strategic locations will be identified for the points of the dose mapping. Selection of these measurement points will be base on certain factor such as physical shielding thickness, occupancy of the workers, and others. Then, several survey meters and dosimeter will be chosen base on measuring method, reactor radiation spectra energy, type of radiation and etc. The result obtained will be compared with action values or limits given by AELB- BSRP 2010 and also can be used as baseline data or report for future reference. (author)

  20. Crucial roles of the protein kinases MK2 and MK3 in a mouse model of glomerulonephritis.

    Directory of Open Access Journals (Sweden)

    Adam J Guess

    Full Text Available Elevated mitogen-activated protein kinase p38 (p38 MAPK signaling has been implicated in various experimental and human glomerulopathies, and its inhibition has proven beneficial in animal models of these diseases. p38 MAPK signaling is partially mediated through MK2 and MK3, two phylogenetically related protein kinases that are its direct substrates. The current study was designed to determine the specific roles of MK2 and MK3 in a mouse model of acute proliferative glomerulonephritis, using mice with disrupted MK2 and/or MK3 genes. We found that the absence of MK3 alone worsened the disease course and increased mortality slightly compared to wild-type mice, whereas the absence of MK2 alone exhibited no significant effect. However, in an MK3-free background, the disease course depended on the presence of MK2 in a gene dosage-dependent manner, with double knock-out mice being most susceptible to disease induction. Histological and renal functional analyses confirmed kidney damage following disease induction. Because the renal stress response plays a crucial role in kidney physiology and disease, we analyzed the stress response pattern in this disease model. We found that renal cortices of diseased mice exhibited a pronounced and specific pattern of expression and/or phosphorylation of stress proteins and other indicators of the stress response (HSPB1, HSPB6, HSPB8, CHOP, eIF2α, partially in a MK2/MK3 genotype-specific manner, and without induction of a general stress response. Similarly, the expression and activation patterns of other protein kinases downstream of p38 MAPK (MNK1, MSK1 depended partially on the MK2/MK3 genotype in this disease model. In conclusion, MK2 and MK3 together play crucial roles in the regulation of the renal stress response and in the development of glomerulonephritis, which can potentially be exploited to develop novel therapeutic approaches to treat glomerular disease.

  1. Experimental and MCNP5 based evaluation of neutron and gamma flux in the irradiation ports of the University of Utah research reactor

    Directory of Open Access Journals (Sweden)

    Noble Brooklyn

    2012-01-01

    Full Text Available Neutron and gamma flux environment of various irradiation ports in the University of Utah training, research, isotope production, general atomics reactor were experimentally assessed and fully modeled using the MCNP5 code. The experimental measurements were based on the cadmium ratio in the irradiation ports of the reactor, flux profiling using nickel wire, and gamma dose measurements using thermo luminescence dosimeter. Full 3-D MCNP5 reactor model was developed to obtain the neutron flux distributions of the entire reactor core and to compare it with the measured flux focusing at the irradiation ports. Integration of all these analysis provided the updated comprehensive neutron-gamma flux maps of the existing irradiation facilities of the University of Utah TRIGA reactor.

  2. Environmental radiation monitoring from the decommission of TRIGA

    Energy Technology Data Exchange (ETDEWEB)

    Choi Geun Sik; Lee, Chang Woo [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-02-01

    Environmental Radiation Monitoring was carried out with measurement of environment radiation and environment radioactivity analysis around TRIGA Research Reactor. The results of environmental radiation monitoring around TRIGA Research Reactor are the follows: The average level of environmental radiation dose measured by potable ERM and accumulated radiation dose by TLD was almost same level compared with the past years. Gross {beta} radioactivity in environmental samples showed a environmental level. v-radionuclides in water samples were not detected. But only radionuclide K-40, which is natural radionuclide, was detected in the all samples and Cs-137 was detected in the surface soil and discharge sediment. 37 refs., 12 figs., 31 tabs. (Author)

  3. Proceedings of 7th short conference on neutron radiography

    International Nuclear Information System (INIS)

    Hiraoka, Eiichi; Katsurayama, Kousuke; Tsujimoto, Tadashi

    1986-10-01

    The first short period conference on neutron radiography was held in 1970, and now the 7th meeting was held. The works to develop neutron radiography in Japan are as active as those in western countries, and the research is in progress by using neutrons from reactors, radioisotopes and accelerators in order to achieve the technology of high standard. In this conference, 26 papers and six comments were presented, and the themes covered the equipment for radiography, the practical application, and the related research. The second World Conference on Neutron Radiography will be held in Paris in June, 1986, and the further promotion of the spread of neutron radiography can be expected. The proceedings of the conference is published with the hope that joint effort and information exchange are further enhanced in coming years to develop the neutron radiography in Japan. The neutron radiography using the Kinki University reactor, the Rikkyo Triga-2 reactor, the Musashi reactor, the Kyoto research reactor, a 3MV Van de Graaff accelerator in Toyota, a subcompact cyclotron in Sumitomo, a baby cyclotron-dual collimator in National Space Development Agency and so on, Cf-252 based thermal neutron radiography, CT with Sb-124/Be neutrons, pulse power neutron source, imaging converters, neutron radiographic image processing, computed tomography using neutron television systems and others are reported. (Kako, I.)

  4. Archaeometric studies by using neutron radiography in ITU TRIGA Mark-II reactor

    International Nuclear Information System (INIS)

    Tugrul, A. Beril

    2008-01-01

    Archaeometric many studies have been done by using neutron radiography in ITU TRIGA Mark-II Training and Research Reactor for over 15 years. Tangential beam tube has been arranged for using neutron radiography. Generally, transfer technique has been preferred with using dysprosium screen, but indium screen also is used. Some studies are described which are all on the Anatolian artefacts. The first study from 13th century AD deals with Seljukian period from south-east Anatolia. It investigated a plate from Great Mosque door in Cizre. With means of the neutron radiography painting traces are investigated on the plates. Organic dye traces are noticed on some of plates, which have generally animal figures. Other studies from Urartu period at the first millennium B.C, investigates artefacts found at the vicinity of Van on east Anatolia. An important one is a sword that was found in a grave. It has some corrosion defects. The neutron radiography was applied and shown that wooden parts are there. Other studies referred to samples from the Ikiztepe Excavation site on north Anatolia. Many artefacts were examined by neutron radiography. Some of them evidenced animal parts are recognised as covering parts. An interesting result was obtained to a sword and its sheath that were corroded together. After the neutron radiography applications, it was noticed that there are a cloth between the sword and its sheath. Hence, it was the cause of corrosion of the artefact. By using neutron radiography, many interesting and detailed results were observed by means of the neutron beam from the ITU TRIGA Mark-II Training and Research Reactor. Some of them could not be evidenced by means of any other technique

  5. Status report of Indonesian research reactor

    International Nuclear Information System (INIS)

    Arbie, B.; Supadi, S.

    1992-01-01

    A general description of three Indonesian research reactor, its irradiation facilities and its future prospect are described. Since 1965 Triga Mark II 250 KW Bandung, has been in operation and in 1972 the design powers were increased to 1000 KW. Using core grid form Triga 250 KW BATAN has designed and constructed Kartini Reactor in Yogyakarta which started its operation in 1979. Both of this Triga type reactors have served a wide spectrum of utilization such as training manpower in nuclear engineering, radiochemistry, isotope production and beam research in solid state physics. Each of this reactor have strong cooperation with Bandung Institute of Technology at Bandung and Gajah Mada University at Yogyakarta which has a faculty of Nuclear Engineering. Since 1976 the idea to have high flux reactor has been foreseen appropriate to Indonesian intention to prepare infrastructure for nuclear industry for both energy and non-energy related activities. The idea come to realization with the first criticality of RSG-GAS (Multipurpose Reactor G.A. Siwabessy) in July 1987 at PUSPIPTEK Serpong area. It is expected that by early 1992 the reactor will reached its full power of 30 MW and by end 1992 its expected that irradiation facilities will be utilized in the future for nuclear scientific and engineering work. (author)

  6. Research work at the TRIGA Mainz reactor

    International Nuclear Information System (INIS)

    Trautmann, Norbert

    1976-01-01

    In the last two years the research activities at the TRIGA Mark II reactor in Mainz have mainly been concentrated on the investigation of short- lived nuclides of medium mass number produced by thermal-neutron induced fission of 235 U and other fissile materials. For the identification of these nuclides and for detailed studies of their properties rapid chemical separation procedures in combination with high-resolution gamma-ray and neutron spectroscopy as well as mass-separated samples have been used. Fast, discontinuous separation techniques are illustrated by a procedure for technetium. Continuous separation methods from aqueous solutions and in the gas phase, accomplished by combining a gas jet recoil transport system with an on-line operating solvent extraction technique and a thermo- chromatographic method, are presented. The application of such procedures to decay scheme and delayed neutron studies is demonstrated by a few examples. The experimental set-up and the method for nuclear spin - and magnetic moment measurements on alkali isotopes far from the region of beta-stability applying the nuclear radiation detected optical pumping technique to mass- separated samples of neutron-rich alkali nuclides are briefly described. (author)

  7. Analysis of JSI TRIGA MARK II reactor physical parameters calculated with TRIPOLI and MCNP.

    Science.gov (United States)

    Henry, R; Tiselj, I; Snoj, L

    2015-03-01

    New computational model of the JSI TRIGA Mark II research reactor was built for TRIPOLI computer code and compared with existing MCNP code model. The same modelling assumptions were used in order to check the differences of the mathematical models of both Monte Carlo codes. Differences between the TRIPOLI and MCNP predictions of keff were up to 100pcm. Further validation was performed with analyses of the normalized reaction rates and computations of kinetic parameters for various core configurations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Neuro-diffuse algorithm for neutronic power identification of TRIGA Mark III reactor

    International Nuclear Information System (INIS)

    Rojas R, E.; Benitez R, J. S.; Segovia de los Rios, J. A.; Rivero G, T.

    2009-10-01

    In this work are presented the results of design and implementation of an algorithm based on diffuse logic systems and neural networks like method of neutronic power identification of TRIGA Mark III reactor. This algorithm uses the punctual kinetics equation as data generator of training, a cost function and a learning stage based on the descending gradient algorithm allow to optimize the parameters of membership functions of a diffuse system. Also, a series of criteria like part of the initial conditions of training algorithm are established. These criteria according to the carried out simulations show a quick convergence of neutronic power estimated from the first iterations. (Author)

  9. Detection of a leaking boron-carbide control rod in a TRIGA Mark I reactor

    Energy Technology Data Exchange (ETDEWEB)

    Blotcky, A J; Arsenault, L J [General Medical Research, Veterans Administration Hospital, Omaha (United States)

    1974-07-01

    During a routine quarterly inspection of the boron-carbide control rods of the Omaha Veterans Administration Hospital 18 kW Triga Mark I reactor, a pin hole leak was detected approximately 3 mm from the chamfered edge. The leak was found by observing bubbles when the rod was withdrawn from the reactor tank for visual observation, and could not be seen with the naked eye. This suggests that pin hole leaks could occur and not be visually detected in control rods and fuel elements examined underwater. A review of the rod calibrations showed that the leak had not caused a loss in rod worth. Slides will be presented showing the bubbles observed during the inspection, together with an unmagnified and magnified view of the pin hole. (author)

  10. Detection of a leaking boron-carbide control rod in a TRIGA Mark I reactor

    International Nuclear Information System (INIS)

    Blotcky, A.J.; Arsenault, L.J.

    1974-01-01

    During a routine quarterly inspection of the boron-carbide control rods of the Omaha Veterans Administration Hospital 18 kW Triga Mark I reactor, a pin hole leak was detected approximately 3 mm from the chamfered edge. The leak was found by observing bubbles when the rod was withdrawn from the reactor tank for visual observation, and could not be seen with the naked eye. This suggests that pin hole leaks could occur and not be visually detected in control rods and fuel elements examined underwater. A review of the rod calibrations showed that the leak had not caused a loss in rod worth. Slides will be presented showing the bubbles observed during the inspection, together with an unmagnified and magnified view of the pin hole. (author)

  11. Status report of Indonesian research reactors

    International Nuclear Information System (INIS)

    Arbie, B.; Supadi, S.

    1995-01-01

    A general description of the three Indonesia research reactors, their irradiation facilities and future prospect are given. The 250 kW Triga Mark II in Bandung has been in operation since 1965 and in 1972 its designed power was increased to 1000 kW. The core grid from the previous 250 kW Triga Mark II was then used by Batan for designing and constructing the Kartini reactor in Yogyakarta. This reactor commenced its operation in 1979. Both Triga reactors have served a wide spectrum of utilization such as for manpower training in nuclear engineering, radiochemistry, isotope production, and beam research in solid state physics. The Triga reactor management in Bandung has a strong cooperation with the Bandung Institute of Technology and the one in Yogyakarta with the Gadjah Mada University which has a Nuclear Engineering Department at its Faculty of Engineering. In 1976 there emerged an idea to have a high flux reactor appropriate for Indonesia's intention to prepare an infrastructure for both nuclear energy and non-energy industry era. Such an idea was then realized with the achievement of the first criticality of the RSG-GAS reactor at the Serpong area. It is now expected that by early 1992 the reactor will reach its full 30 MW power level and by the end of 1992 the irradiation facilities be utilizable fully for future scientific and engineering work. As a part of the national LEU fuel development program a study has been underway since early 1989 to convert the RSG-GAS reactor core from using oxide fuel to using higher loading silicide fuel. (author)

  12. Feasibility study of application of Prompt Gamma Neutron Activation Analysis (PGNAA) method in TRIGA IPR-R1 reactor; Estudo da viabilidade de aplicação do método Prompt Gamma Neutron Activation Analysis (PGNAA) no reator TRIGA IPR-R1

    Energy Technology Data Exchange (ETDEWEB)

    Guerra, Bruno Teixeira

    2016-07-01

    The TRIGA Mark I IPR-R1 research reactor is located at Nuclear Technology Development Centre (CDTN), Brazilian Commission for Nuclear Energy (CNEN), in Belo Horizonte, Brazil. The reactor operates at 100 kW but the core configuration allows the increasing of the power up to 250 kW. It has been applied research, training and radioisotopes production. The establishment of the Prompt Gamma Neutron Activation Analysis (PGNAA) method at the TRIGA IPR-R1 reactor will significantly increase the types of matrices analysed as well as the number of chemical elements. Additionally it will complement the neutron activation analysis. This work presents a proposed design of a PGNAA facility to be installed at the TRIGA IPR-R1. The proposed design is based on a tube as a neutron guide from the reactor core, inside the reactor pool, 6 m below the room’s level where shall be located the rack containing the set sample/detector/shielding. Thus, the aim of this study is to verify the feasibility to establish the PGNAA method in IPR-R1 through theoretical study applying the Monte Carlo code. The feasibility of establishing the PGAA method at the IPR-R1 installations was evaluated through of the calculations of neutron flux, radioactive capture reaction rates and detection limits for some isotopes. According to the obtained results, it can be concluded that is possible to establish the PGAA method at the IPR-R1 reactor, even with some restrictions in its theoretical design calculated by MCNP. (author)

  13. IFPE/EFE-RO, Experimental Fuel Elements RO89 and RO51 in TRIGA 14 MW Reactor (INR-Pitesti)

    International Nuclear Information System (INIS)

    Paraschiv, Marius; Turnbull, J.A.

    2002-01-01

    Description of program or function: Romanian irradiation tests concerned with Candu type fuel elements behavior and with the limits of the design parameters. A particular feature of the Candu fuel project is the small plenum (void volume) added for relaxation of the fission gases, which are inherently released during the fuel irradiation. Two irradiation tests in the C2 device from the TRIGA 14 MW reactor were performed between the years 1985-1987. The tests were done to evaluate the effect of the fuel density on the time-evolution of the fission gas pressure. Experimental fuel elements were adequately instrumented with pressure transducers to follow the fission gas pressure changes during fuel irradiation. The first irradiation test was conducted on the fuel element coded No.89 whose main characteristics were the nominal values of the main fuel design parameters. The second one was conducted on the fuel element coded No.51. Because of the axial flux asymmetry inside the TRIGA reactor core, the experimental elements are shorter in length than the Candu fuel design. The irradiation tests consisted in evaluation of the time-evolution of the internal pressure from two experimental fuel elements having the main design characteristics as the Romanian Candu type fuel element design and to follow the dependence of the internal pressure of the fission gas on the fuel density

  14. Safety-evaluation report related to renewal of the operating license for the Texas A and M University Research Reactor. Docket No. 50-128, License R-83

    International Nuclear Information System (INIS)

    1983-03-01

    This Safety Evaluation Report for the application filed by the Texas A and M University (Texas A and M) for a renewal of operating license number R-83 to continue to operate a research reactor has been prepared by the Office of Nuclear Reactor Regulation of the US Nuclear Regulatory Commission. The facility is owned and operated by the Texas Engineering and Experiment Station of the Texas A and M University and is located on the campus in College Station, Brazos County, Texas. The staff concludes that the TRIGA reactor facility can continue to be operated by Texas A and M University without endangering the health and safety of the public

  15. The IPR-R1 TRIGA Mark I Reactor in 39 years: Operations and general improvements

    International Nuclear Information System (INIS)

    Maretti Junior, Fausto; Prado Fernandes, Marcio; Oliveira, Paulo Fernando; Alves de Amorim, Valter

    1999-01-01

    The nuclear IPR-R1 TRIGA Mark I Reactor operating in the Nuclear Technology Development Center, originally Institute for Radioactive Research in Minas Gerais, Brazil, was dedicated in November 11, 1960. Initially operating for the production of radioisotopes for different uses, it started later to be used in large scale for neutron activation analysis and training of operators for nuclear power plants. Many improvements have been made throughout these years to provide a better performance in its operation and safety conditions. A new cooling system to operate until 300 kW, a new control rod mechanism, an aluminum tank for the reactor pool, an optimization in the pneumatic system, a new reactor control console and a general remodeling of the reactor laboratory were some of the improvements added. To prevent and mitigate the ageing effects, the reactor operation personnel is starting a program to minimize future operation problems. This paper describes the improvements made, the results obtained during the past 39 years, and the precautions taken to ensure future safe operation of the reactor to give operators better conditions of safe work. (author)

  16. 10. biennial U.S. TRIGA users' conference. Papers and abstracts

    International Nuclear Information System (INIS)

    1986-01-01

    The conference cover the following main topics for TRIGA reactors: reactor instrumentation and measurements of reactor parameters, reactor operation and modifications, design innovation and service works, fast neutron spectrum, fuel examination, neutron flux, heat transfer, accidents analysis, corrosion problems, fuel failures and fuel management, mechanical problems and maintenance

  17. Fundamental approach to TRIGA steady-state thermal-hydraulic CHF analysis

    International Nuclear Information System (INIS)

    Feldman, E.

    2008-01-01

    Methods are investigated for predicting the power at which critical heat flux (CHF) occurs in TRIGA reactors that rely on natural convection for primary flow. For a representative TRIGA reactor, two sets of functions are created. For the first set, the General Atomics STAT code and the more widely-used RELAP5-3D code are each employed to obtain reactor flow rate as a function of power. For the second set, the Bernath correlation, the 2006 Groeneveld table, the Hall and Mudawar outlet correlation, and each of the four PG-CHF correlations for rod bundles are used to predict the power at which CHF occurs as a function of channel flow rate. The two sets of functions are combined to yield predictions of the power at which CHF occurs in the reactor. A combination of the RELAP5-3D code and the 2006 Groeneveld table predicts 67% more CHF power than does a combination of the STAT code and the Bernath correlation. Replacing the 2006 Groeneveld table with the Bernath CHF correlation (while using the RELAP5-3D code flow solution) causes the increase to be 23% instead of 67%. Additional RELAP5-3D flow-versus-power solutions obtained from Reference 1 and presented in Appendix B for four specific TRIGA reactors further demonstrates that the Bernath correlation predicts CHF to occur at considerably lower power levels than does the 2006 Groeneveld table. Because of the lack of measured CHF data in the region of interest to TRIGA reactors, none of the CHF correlations considered can be assumed to provide the definitive CHF power. It is recommended, however, to compare the power levels of the potential limiting rods with the power levels at which the Bernath and 2006 Groeneveld CHF correlations predict CHF to occur

  18. Computer programs for TRIGA calibration, burnup evaluation, and bookkeeping

    International Nuclear Information System (INIS)

    Nelson, George W.

    1978-01-01

    Several computer programs have been developed at the University of Arizona to assist the direction and operation of the TRIGA Reactor Laboratory. The programs fall into the following three categories: 1. Programs for calculation of burnup of each fuel element in the reactor core, for maintaining an inventory of fuel element location and fissile content at any time, and for evaluation of the reactivity effects of burnup or proposed fuel element rearrangement in the core. 2. Programs for evaluation, function fitting, and tabulation of control rod measurements. 3. Bookkeeping programs to summarize and tabulate reactor runs and irradiations according to time, energy release, purpose, responsible party, etc. These summarized data are reported in an annual operating report for the facility. The use of these programs has saved innumerable hours of repetitious work, assuring more accurate, objective results, and requiring a minimum of effort to repeat calculations when input data are modified. The programs are written in FORTRAN-IV, and have been used on a CDC-6400 computer. (author)

  19. Development of the user interface for visualization of the auxiliary systems of the TRIGA Mark III nuclear reactor

    International Nuclear Information System (INIS)

    Merced D, J. E.

    2016-01-01

    The Instituto Nacional de Investigaciones Nucleares (ININ) has a nuclear research reactor type swimming pool with movable core cooled and moderate with light water. The nominal maximum power of the reactor is 1 MW in steady-state operation and can be pulsed at a maximum power of 2,000 MW for approximately 10 milliseconds. This reactor is mainly used to study the effects of radiation on various materials and substances. In 2001 the new control console of the nuclear reactor was installed which was based on two digital computers, one computer controls the bar management mechanisms and the other the systems to the reactor operator. In 2004, the control computer was replaced and the software was updated. Within the modernization and/or updating of the TRIGA Mark III reactor of ININ, is intended (theme of this work) to develop the user interface for the visualization of the auxiliary systems, through a Man-Machine Interface module for the renewal process of the control console. The man-machine interface system to be developed will have communication with the programmable logic controllers that will be constantly monitored and controlled to obtain real-time variables of the reactor behavior. (Author)

  20. Conceptual design of a clinical BNCT beam in an adjacent dry cell of the Jozef Stefan Institute TRIGA reactor

    NARCIS (Netherlands)

    Maucec, M

    The MCNP4B Monte Carlo transport code is used in a feasibility study of the epithermal neutron boron neutron capture therapy facility in the thermalizing column of the 250-kW TRIGA Mark II reactor at the Jozef Stefan Institute (JSI). To boost the epithermal neutron flux at the reference irradiation

  1. Conceptual design of a clinical BNCT beam in an adjacent dry cell of the Jozef Stefan Institute TRIGA reactor

    NARCIS (Netherlands)

    Maucec, M

    2000-01-01

    The MCNP4B Monte Carlo transport code is used in a feasibility study of the epithermal neutron boron neutron capture therapy facility in the thermalizing column of the 250-kW TRIGA Mark II reactor at the Jozef Stefan Institute (JSI). To boost the epithermal neutron flux at the reference irradiation

  2. Development and validation of a model TRIGA Mark III reactor with code MCNP5; Desarrollo y validacion de un modelo del reactor Triga Mark III con el codigo MCNP5

    Energy Technology Data Exchange (ETDEWEB)

    Galicia A, J.; Francois L, J. L. [UNAM, Facultad de Ingenieria, Departamento de Sistemas Energeticos, Ciudad Universitaria, 04510 Ciudad de Mexico (Mexico); Aguilar H, F., E-mail: blink19871@hotmail.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2015-09-15

    The main purpose of this paper is to obtain a model of the reactor core TRIGA Mark III that accurately represents the real operating conditions to 1 M Wth, using the Monte Carlo code MCNP5. To provide a more detailed analysis, different models of the reactor core were realized by simulating the control rods extracted and inserted in conditions in cold (293 K) also including an analysis for shutdown margin, so that satisfied the Operation Technical Specifications. The position they must have the control rods to reach a power equal to 1 M Wth, were obtained from practice entitled Operation in Manual Mode performed at Instituto Nacional de Investigaciones Nucleares (ININ). Later, the behavior of the K{sub eff} was analyzed considering different temperatures in the fuel elements, achieving calculate subsequently the values that best represent the actual reactor operation. Finally, the calculations in the developed model for to obtain the distribution of average flow of thermal, epithermal and fast neutrons in the six new experimental facilities are presented. (Author)

  3. On-site emergency intervention plan for nuclear accident situation at SCN-Pitesti TRIGA Reactor

    International Nuclear Information System (INIS)

    Margeanu, S.; Oprea, I.

    2008-01-01

    A 14 MW TRIGA research reactor is operated on the Institute for Nuclear Research site. In the event of a nuclear accident or radiological emergency that may affect the public the effectiveness of protective actions depends on the adequacy of intervention plans prepared in advance. Considerable planning is necessary to reduce to manageable levels the types of decisions leading to effective responses to protect the public in such an event. The essential structures of our on-site, off-site and county emergency intervention plan and the correlation between emergency intervention plans are presented. (authors)

  4. Research reactor decommissioning experience - concrete removal and disposal -

    International Nuclear Information System (INIS)

    Manning, Mark R.; Gardner, Frederick W.

    1990-01-01

    Removal and disposal of neutron activated concrete from biological shields is the most significant operational task associated with research reactor decommissioning. During the period of 1985 thru 1989 Chem-Nuclear Systems, Inc. was the prime contractor for complete dismantlement and decommissioning of the Northrop TRIGA Mark F, the Virginia Tech Argonaut, and the Michigan State University TRIGA Mark I Reactor Facilities. This paper discusses operational requirements, methods employed, and results of the concrete removal, packaging, transport and disposal operations for these (3) research reactor decommissioning projects. Methods employed for each are compared. Disposal of concrete above and below regulatory release limits for unrestricted use are discussed. This study concludes that activated reactor biological shield concrete can be safely removed and buried under current regulations

  5. 9. European TRIGA users' conference. Papers and abstracts

    International Nuclear Information System (INIS)

    1986-01-01

    Operation and maintenance experience, new developments and improvements of TRIGA reactors, fuel management, radiation protection, licensing, uses for research and isotope production are discussed at the Conference

  6. Obtaining of total and thermal neutron flux in the carousel facility of the TRIGA MARK IPR-R1 reactor using the Monte Carlo transport method

    International Nuclear Information System (INIS)

    Guerra, Bruno Teixeira

    2011-01-01

    The IPR-R1 is a reactor type TRIGA, Mark-I model, manufactured by the General Atomic Company and installed at Nuclear Technology Development Centre (CDTN) of Brazilian Nuclear Energy Commission (CNEN), in Belo Horizonte, Brazil. It is a light water moderated and cooled, graphite-reflected, open-pool type research reactor. IPR-R1 works at 100 kW but it will be briefly licensed to operate at 250 kW. It presents low power, low pressure, for application in research, training and radioisotopes production. The fuel is an alloy of zirconium hydride and uranium enriched at 20% in 235 U. The goal this work is modelling of the IPR-R1 Research Reactor TRIGA using the codes MCNPX2.6.0 (Monte Carlo N-Particle Transport extend) and MCNP5 to the calculating the neutron flux in the carousel facility. In each simulation the sample was placed in a different position, totaling forty positions around of the reactor core. The comparison between the results obtained with experimental values from other work showing a relatively good agreement. Moreover, this methodology is a theoretical tool in validating of the experimental values and necessary for determining neutron flux which can not be accessible experimentally. (author)

  7. Operation experience at the TRIGA Mark III reactor FRN within the last two years

    International Nuclear Information System (INIS)

    Rau, G.

    1976-01-01

    A survey is given of the history of FRN-reactor operation since the last TRIGA conference. In 1975, the reactor had been operated for 830 MWh and had been pulsed 1050 times. In the first half of 1976, an appreciable Increase of reactor activities took place. In this time interval, the integrated power amounted to 996 MWh and the number of released pulses to 1024. In 1975, an important event was the exchange of the defective rotary specimen rack against a water-operated type. For this purpose, the whole core had to be unloaded and the pool water had to be removed. In this connection, damages at the beam-port weldings had been discovered and had to be repaired immediately. In December 1975, a new core configuration had been set up by adding ten spare fuel elements into the F-resp. G-ring. The gain of excess reactivity amounted to approximately 1,8 $. This however allowed reactor operation without disturbance by Xe-poisoning only for a limited time interval. (author)

  8. Development of System Model for Level 1 Probabilistic Safety Assessment of TRIGA PUSPATI Reactor

    International Nuclear Information System (INIS)

    Tom, P.P; Mazleha Maskin; Ahmad Hassan Sallehudin Mohd Sarif; Faizal Mohamed; Mohd Fazli Zakaria; Shaharum Ramli; Muhamad Puad Abu

    2014-01-01

    Nuclear safety is a very big issue in the world. As a consequence of the accident at Fukushima, Japan, most of the reactors in the world have been reviewed their safety of the reactors including also research reactors. To develop Level 1 Probabilistic Safety Assessment (PSA) of TRIGA PUSPATI Reactor (RTP), three organizations are involved; Nuclear Malaysia, AELB and UKM. PSA methodology is a logical, deductive technique which specifies an undesired top event and uses fault trees and event trees to model the various parallel and sequential combinations of failures that might lead to an undesired event. Fault Trees (FT) methodology is use in developing of system models. At the lowest level, the Basic Events (BE) of the fault trees (components failure and human errors) are assigned probability distributions. In this study, Risk Spectrum software used to construct the fault trees and analyze the system models. The results of system models analysis such as core damage frequency (CDF), minimum cut set (MCS) and common cause failure (CCF) uses to support decision making for upgrading or modification of the RTP?s safety system. (author)

  9. Verification of the linearity of the IPR-R1 TRIGA reactor power channels

    International Nuclear Information System (INIS)

    Souza, Rose Mary Gomes do Prado; Campolina, Daniel de Almeida Magalhaes

    2013-01-01

    The aim of this paper is to verify the linearity of the three power channels of the IPR-R1 TRIGA reactor. Located at Nuclear Technology Development Center-CDTN in Belo Horizonte, the IPR-R1 reactor is a typical 100 kW Mark I light-water reactor cooled by natural convection. When the experiments were performed, the reactor core had 59 fuel elements, containing 8% by weight of uranium enriched to 20% in 235 U. The core has cylindrical configuration with an annular graphite reflector. The responses of the detectors of the Linear, Log N and Percent Power channels were compared with the responses of detectors which only depend on the overall neutron flux within the reactor. Gold and cobalt foils were activated at low and high powers, respectively, and the specific count results were compared with measurements performed, simultaneously, with a fission chamber, and with the power registered by the three channels. The results show that the Linear channel responds linearly up to 100 kW, and the Log N channel responses are linear at low powers. In the range of high power, the Log N and the Percent Power channels exhibit linearity only from 10 kW to 50 kW. (author)

  10. Sensitivity analysis to a RELAP5 nodalization developed for a typical TRIGA research reactor

    International Nuclear Information System (INIS)

    Reis, Patrícia A.L.; Costa, Antonella L.; Pereira, Claubia; Silva, Clarysson A.M.; Veloso, Maria Auxiliadora F.

    2012-01-01

    Highlights: ► We investigated how much the code results are affected by the code user. ► Two essential modifications were made on a previously validated nodalization. ► We used the RELAP5 code to predict the results. ► Results highlight the necessity of sensitivity analysis to have the ideal modeling. - Abstract: The main aim of this work is to identify how much the code results are affected by the code user in the choice of, for example, the number of thermal hydraulic channels in a nuclear reactor nodalization. To perform this, two essential modifications were made on a previously validated nodalization for analysis of steady-state and forced recirculation off transient in the IPR-R1 TRIGA research reactor. Experimental data were taken as reference to compare the behavior of the reactor for two different types of modeling. The results highlight the necessity of sensitivity analysis to obtain the ideal modeling to simulate a specific system.

  11. Research Reactor Utilization at the University of Utah for Nuclear Education, Training and Services

    International Nuclear Information System (INIS)

    Jevremovic, T.; Choe, D.O.

    2013-01-01

    In the years of nuclear renaissance we all recognize a need for modernizing the approaches in fostering nuclear engineering and science knowledge, in strengthening disciplinary depth in students’ education for their preparation for workforce, and in helping them learn how to extend range of skills, develop habits of mind and subject matter knowledge. The education infrastructure at the University of Utah has been recently revised to incorporate the experiential learning using our research reactor as integral part of curriculum, helping therefore that all of our students build sufficient level of nuclear engineering literacy in order to be able to contribute productively to nuclear engineering work force or continue their education toward doctoral degrees. The University of Utah TRIGA Reactor built 35 years ago represents a university wide facility to promote research, education and training, as well as is used for various applications of nuclear engineering, radiation science and health physics. Our curriculum includes two consecutive classes for preparation of our students for research reactor operating license. Every year the US Nuclear Regulatory Commission’s representatives hold the final exam for our students. Our activities serve the academic community of the University of Utah, commercial and government entities, other universities and national laboratories as well. (author)

  12. IGORR 2: Proceedings of the 2. meeting of the International Group On Research Reactors

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1992-07-01

    The International group on Research Reactors was formed to facilitate the sharing of knowledge and experience among those institutions and individuals who are actively working to design, build, and promote new research reactors or to make significant upgrades to existing facilities. Sessions during this second meeting were devoted to research reactor reports (GRENOBLE reactor, FRM-II, HIFAR, PIK, reactors at JAERI, MAPLE, ANS, NIST, MURR, TRIGA, BR-2, SIRIUS 2); other neutron sources; and two workshops were dealing with research and development results and needs and reports on progress in needed of R and D areas identified at IGORR 1.

  13. IGORR 2: Proceedings of the 2. meeting of the International Group On Research Reactors

    International Nuclear Information System (INIS)

    1992-01-01

    The International group on Research Reactors was formed to facilitate the sharing of knowledge and experience among those institutions and individuals who are actively working to design, build, and promote new research reactors or to make significant upgrades to existing facilities. Sessions during this second meeting were devoted to research reactor reports (GRENOBLE reactor, FRM-II, HIFAR, PIK, reactors at JAERI, MAPLE, ANS, NIST, MURR, TRIGA, BR-2, SIRIUS 2); other neutron sources; and two workshops were dealing with research and development results and needs and reports on progress in needed of R and D areas identified at IGORR 1

  14. Three-dimensional coupled kinetics/thermal- hydraulic benchmark TRIGA experiments

    International Nuclear Information System (INIS)

    Feltus, Madeline Anne; Miller, William Scott

    2000-01-01

    This research project provides separate effects tests in order to benchmark neutron kinetics models coupled with thermal-hydraulic (T/H) models used in best-estimate codes such as the Nuclear Regulatory Commission's (NRC) RELAP and TRAC code series and industrial codes such as RETRAN. Before this research project was initiated, no adequate experimental data existed for reactivity initiated transients that could be used to assess coupled three-dimensional (3D) kinetics and 3D T/H codes which have been, or are being developed around the world. Using various Test Reactor Isotope General Atomic (TRIGA) reactor core configurations at the Penn State Breazeale Reactor (PSBR), it is possible to determine the level of neutronics modeling required to describe kinetics and T/H feedback interactions. This research demonstrates that the small compact PSBR TRIGA core does not necessarily behave as a point kinetics reactor, but that this TRIGA can provide actual test results for 3D kinetics code benchmark efforts. This research focused on developing in-reactor tests that exhibited 3D neutronics effects coupled with 3D T/H feedback. A variety of pulses were used to evaluate the level of kinetics modeling needed for prompt temperature feedback in the fuel. Ramps and square waves were used to evaluate the detail of modeling needed for the delayed T/H feedback of the coolant. A stepped ramp was performed to evaluate and verify the derived thermal constants for the specific PSBR TRIGA core loading pattern. As part of the analytical benchmark research, the STAR 3D kinetics code (, STAR: Space and time analysis of reactors, Version 5, Level 3, Users Guide, Yankee Atomic Electric Company, YEAC 1758, Bolton, MA) was used to model the transient experiments. The STAR models were coupled with the one-dimensional (1D) WIGL and LRA and 3D COBRA (, COBRA IIIC: A digital computer program for steady-state and transient thermal-hydraulic analysis of rod bundle nuclear fuel elements, Battelle

  15. Immobilization of ion exchange radioactive resins of the TRIGA Mark III nuclear reactor

    International Nuclear Information System (INIS)

    Garcia M, H.; Emeterio H, M.; Canizal S, C.

    1999-01-01

    This work has the objective to develop the process and to define the agglutinating material which allows the immobilization of the ion exchange radioactive resins coming from the TRIGA Mark III nuclear reactor contaminated with Ba-133, Co-60, Cs-137, Eu-152, and Mn-54 through the behavior analysis of different immobilization agents such as: bitumens, cement and polyester resin. According to the International Standardization the archetype samples were observed with the following tests: determination of free liquid, leaching, charge resistance, biodegradation, irradiation, thermal cycle, burned resistance. Generally all the tests were satisfactorily achieved, for each agent. Therefore, the polyester resin could be considered as the main immobilizing. (Author)

  16. Coordination of motor systems of the control bars of TRIGA Mark III reactor, through the use of a PLC; Coordinacion de los sistemas motrices de las barras de control del reactor Triga Mark III, mediante el uso de un PLC

    Energy Technology Data Exchange (ETDEWEB)

    Castro R, P. R.

    2016-07-01

    The use of programmable logic controllers (PLCs) has a wide field in the realization of automatic systems, since is sought that the form of control is easy for any user. In this work, the TRIGA Mark III reactor of Instituto Nacional de Investigaciones Nucleares (ININ) is intended to operate with a programming code in PLC for the automation of the control rods, having uniform wear according to the power required by the user. On the other hand, is proposed to develop an HMI graphical interface for communication via Ethernet, allowing supervision during the reactor operation process and greater protection of operators during reactor startup. The accuracy of the new actuators, as well as their durability, will allow a good performance of the reactor for many years to come. (Author)

  17. Licensing of the TRIGA Mark III reactor at the Mexican Nuclear Centre

    International Nuclear Information System (INIS)

    Ramirez, R.M.; Arrendondo, R.R.

    1990-01-01

    The TRIGA Mark III reactor at the Mexican Nuclear Centre went critical in 1968 and remained so until 1979 when the National Commission for Nuclear Safety and Safeguards (CNSNS), the Mexican regulatory authority, was set up. The reactor was therefore operating without a formal operating license, and the CNSNS accordingly requested the ININ to license the reactor under the existing conditions and to ensure that any modification of the original design complied with Standards ANSI/ANS-15 and with the code of practice set out in IAEA Safety Series No. 35. The most relevant points in granting the operating licence were: (a) the preparation of the Safety Report; (b) the formulation and application of the Quality Assurance Programme; (c) the reconditioning of the following reactor systems: the cooling systems; the ventilation and exhaust system; the monitoring system and control panel; (d) the training of the reactor operating staff at junior and senior levels; and (e) the formulation of procedures and instructions. Once the provisional operating license was obtained for the reactor it was considered necessary to modify the reactor core, which has been composed of 20% enriched standards fuel, to a mixed core based on a mixture of standard fuel and FLIP-type fuel with 70% 235 U enrichment. The CNSNS therefore requested that the mixed core be licensed and a technical report was accordingly annexed to the Safety Report, its contents including the following subjects: (a) neutron analysis of the proposed configuration; (b) reactor shutdown margins; (c) accident analysis; and (d) technical specifications. The licensing process was completed this year and we are now hoping to obtain the final operating license

  18. Criticality and safety parameter studies for upgrading 3 MW TRIGA MARK II research reactor and validation of generated cross section library and computational method

    International Nuclear Information System (INIS)

    Bhuiyan, S.I.; Mondal, M.A.W.; Sarker, M.M.; Rahman, M.; Shahdatullah, M.S.; Huda, M.Q.; Chakrroborty, T.K.; Khan, M.J.H.

    2000-01-01

    This study deals with the neutronic and thermal hydraulic analysis of the 3MW TRIGA MARK II research reactor to upgrade it to a higher flux. The upgrading will need a major reshuffling and reconfiguration of the current core. To reshuffle the current core configuration, the chain of NJOY94.10 - WIMSD-5A - CITATION - PARET - MCNP4B2 codes has been used for the overall analysis. The computational methods, tools and techniques, customisation of cross section libraries, various models for cells and super cells, and a lot of associated utilities have been standardised and established/validated for the overall core analysis. Analyses using the 4-group and 7-group libraries of macroscopic cross sections generated from the 69-group WIMSD-5 library showed that a 7-group structure is more suitable for TRIGA calculations considering its LEU fuel composition. The MCNP calculations established that the CITATION calculations and the generated cross section library are reasonably good for neutronic analysis of TRIGA reactors. Results obtained from PARET demonstrated that the flux upgrade will not cause the temperature limit on the fuel to be exceeded. Also, the maximum power density remains, by a substantial margin below the level at which the departure from nucleate boiling could occur. A possible core with two additional irradiation channels around the CT is projected where almost identical thermal fluxes as in the CT are obtained. The reconfigured core also shows 7.25% thermal flux increase in the Lazy Susan. (author)

  19. Corrosion Induced Leakage Problem of the Radial Beam Port 1 of BAEC Triga Mark-II Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kalam, A.; Salam, M. A.; Sarder, M. A.; Rahman, M. M.; Rahman, M.; Rahman, A.; Chowdhury, A. Z.; Uddin, M. S.; Haque, M. M.; Zulquarnain, M.A., E-mail: kalambaec@yahoo.com [Reactor Operation and Maintenance Unit, Atomic Energy Research Establishment (AERE), Dhaka (Bangladesh)

    2014-08-15

    The BAEC reactor has so far been operated as per the technical specifications and procedures laid down in the SAR of the research reactor. The BP leakage problem of the BAEC research reactor was an issue that could lead to a situation close to a LOCA. Therefore, the matter was handled carefully, taking all measures so that such an incident could be prevented. Assistance of agencies outside BAEC was taken for solving the problem. It is understood that the silicone rubber lining of the encirclement clamp may become damaged by neutron irradiation. Therefore, while designing the clamp, provisions were kept such that it can be dismantled and reinstalled again following lining replacement. As a moderately aged facility, the ageing management BAEC TRIGA research reactor deserves significant attention. BAEC, together with its strategic partners, are doing what is needed in this regard.

  20. Electron versus proton accelerator driven sub-critical system performance using TRIGA reactors at power

    International Nuclear Information System (INIS)

    Carta, M.; Burgio, N.; D'Angelo, A.; Santagata, A.; Petrovich, C.; Schikorr, M.; Beller, D.; Felice, L. S.; Imel, G.; Salvatores, M.

    2006-01-01

    This paper provides a comparison of the performance of an electron accelerator-driven experiment, under discussion within the Reactor Accelerator Coupling Experiments (RACE) Project, being conducted within the U.S. Dept. of Energy's Advanced Fuel Cycle Initiative (AFCI), and of the proton-driven experiment TRADE (TRIGA Accelerator Driven Experiment) originally planned at ENEA-Casaccia in Italy. Both experiments foresee the coupling to sub-critical TRIGA core configurations, and are aimed to investigate the relevant kinetic and dynamic accelerator-driven systems (ADS) core behavior characteristics in the presence of thermal reactivity feedback effects. TRADE was based on the coupling of an upgraded proton cyclotron, producing neutrons via spallation reactions on a tantalum (Ta) target, with the core driven at a maximum power around 200 kW. RACE is based on the coupling of an Electron Linac accelerator, producing neutrons via photoneutron reactions on a tungsten-copper (W-Cu) or uranium (U) target, with the core driven at a maximum power around 50 kW. The paper is focused on analysis of expected dynamic power response of the RACE core following reactivity and/or source transients. TRADE and RACE target-core power coupling coefficients are compared and discussed. (authors)

  1. Relationship between general safety requirements and safety culture in the improvement of safe operation of I.N.R. TRIGA reactor facilities

    International Nuclear Information System (INIS)

    Ciocanescu, M.; Preda, M.; Chiritescu, M.; Dumitru, M.

    1996-01-01

    Acquiring of the basic principles of ''safety culture'' by a large number of profesionals in the nuclear field drew the attention of the decision factors in the INR managerial structure, who decided to promote certain practical actions at each level in order to improve nuclear safety. Starting from the ''Republican Standards for Nuclear Safety'' issued by CSEN in 1975, where general safety criteria are defined for nuclear reactors and NPPs, the specialists at the TRIGA reactor originated and implemented a coherent and secure system to ensure nuclear safety over all steps of nuclear activities: research, conception, execution, commissioning and operation. This system has been continuosly corrected so that now it is completely integrated in a modern safety system. The paper presents the way in which a modern system for nuclear safety at the TRIGA reactor has been implemented and developed, in accordance to specific criteria and requirements imposed by related National Regulations and with the principles of safety culture. Starting from the definition of specific responsabilities, there are presented the internal stipulations and practical actions at all levels in order to enhance nuclear safety. (orig.)

  2. Seed irradiation facilities at TRIGA Mark II reactor

    International Nuclear Information System (INIS)

    Najzer, M.

    1972-01-01

    Fast neutrons and gamma-rays with their high and low LET respectively are excellent complementary tools for investigation of the effect of different types of mutations. TRIGA Irradiation Facility and Thermal Column Irradiation Facility were designed and installed for the first time in the TRIGA tank and thermal column respectively. The basic idea of design was the use of depleted uranium as gamma-ray and thermal neutron shield and simultaneously as thermal to fast neutron converter. Low LET radiation, due to direct and thermal neutron capture gamma-rays, is strongly attenuated while fast neutron flux is increased. GIF is made of a cadmium tube inserted in a graphite block. It is located in the central thermal column channel. The basic idea is to convert thermal neutrons to gamma-rays by capture in the cadmium

  3. Adaptive control method for core power control in TRIGA Mark II reactor

    Science.gov (United States)

    Sabri Minhat, Mohd; Selamat, Hazlina; Subha, Nurul Adilla Mohd

    2018-01-01

    The 1MWth Reactor TRIGA PUSPATI (RTP) Mark II type has undergone more than 35 years of operation. The existing core power control uses feedback control algorithm (FCA). It is challenging to keep the core power stable at the desired value within acceptable error bands to meet the safety demand of RTP due to the sensitivity of nuclear research reactor operation. Currently, the system is not satisfied with power tracking performance and can be improved. Therefore, a new design core power control is very important to improve the current performance in tracking and regulate reactor power by control the movement of control rods. In this paper, the adaptive controller and focus on Model Reference Adaptive Control (MRAC) and Self-Tuning Control (STC) were applied to the control of the core power. The model for core power control was based on mathematical models of the reactor core, adaptive controller model, and control rods selection programming. The mathematical models of the reactor core were based on point kinetics model, thermal hydraulic models, and reactivity models. The adaptive control model was presented using Lyapunov method to ensure stable close loop system and STC Generalised Minimum Variance (GMV) Controller was not necessary to know the exact plant transfer function in designing the core power control. The performance between proposed adaptive control and FCA will be compared via computer simulation and analysed the simulation results manifest the effectiveness and the good performance of the proposed control method for core power control.

  4. Development of a simulator for design and test of power controllers in a TRIGA Mark III reactor

    International Nuclear Information System (INIS)

    Perez M, C.; Benitez R, J.S.; Lopez C, R.

    2003-01-01

    The development of a simulator that uses the Runge-Kutta-Fehlberg method to solve the model of the punctual kinetics of a nuclear research reactor type TRIGA. The simulator includes an algorithm of power control of the reactor based on the fuzzy logic, a friendly graphic interface which responds to the different user's petitions and that it shows numerical and graphically the results in real time. The user can modify the demanded power and to visualize the dynamic behavior of the one system. This simulator was developed in Visual Basic under an open architecture with which its will be prove different controllers for its analysis. (Author)

  5. Simulation on reactor TRIGA Puspati core kinetics fueled with thorium (Th) based fuel element

    Energy Technology Data Exchange (ETDEWEB)

    Mohammed, Abdul Aziz, E-mail: azizM@uniten.edu.my; Rahman, Shaik Mohmmed Haikhal Abdul [Universiti Tenaga Nasional. Jalan Ikram-UNITEN, 43000 Kajang, Selangor (Malaysia); Pauzi, Anas Muhamad, E-mail: anas@uniten.edu.my; Zin, Muhamad Rawi Muhammad; Jamro, Rafhayudi; Idris, Faridah Mohamad [Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor (Malaysia)

    2016-01-22

    In confronting global energy requirement and the search for better technologies, there is a real case for widening the range of potential variations in the design of nuclear power plants. Smaller and simpler reactors are attractive, provided they can meet safety and security standards and non-proliferation issues. On fuel cycle aspect, thorium fuel cycles produce much less plutonium and other radioactive transuranic elements than uranium fuel cycles. Although not fissile itself, Th-232 will absorb slow neutrons to produce uranium-233 ({sup 233}U), which is fissile. By introducing Thorium, the numbers of highly enriched uranium fuel element can be reduced while maintaining the core neutronic performance. This paper describes the core kinetic of a small research reactor core like TRIGA fueled with a Th filled fuel element matrix using a general purpose Monte Carlo N-Particle (MCNP) code.

  6. Neutronic calculations in core conversion of the IAN-R1 research reactor from MTR HEU to TRIGA LEU fuel

    International Nuclear Information System (INIS)

    Sarta Fuentes, Jose A.; Castiblanco, L.A.

    2003-01-01

    With cooperation of the International Atomic Energy Agency (IAEA), neutronic calculations were carried out for conversion of the Ian-R1 Reactor from MTR-HEU fuel to TRIGA-LEU fuel. In order to establish a staff for neutronic calculation at the Instituto de Cancan's Nucleares y Energia s Alternatives (INEA) a program was established. This program included training, acquisition of hardware, software and calculation for the core with MTR-HEU fuel , enriched nominally to 93% and calculation for several arrangements with the TRIGA-LEU fuel, enriched to 19.7%. The results were verified and compared with several groups of calculation at the Instituto Nacional de Investigaciones Nucleares (ININ) in Mexico, and General Atomics (GA) in United States. As a result of this program, several technical reports have been wrote. (author)

  7. Dose estimation in B16 tumour bearing mice for future irradiation in the thermal column of the TRIGA reactor after B/Gd/LDL adduct infusion

    Energy Technology Data Exchange (ETDEWEB)

    Protti, N., E-mail: nicoletta.protti@pv.infn.it [University of Pavia, Department of Nuclear and Theoretical Physics, via Bassi 6, 27100 Pavia (Italy)] [National Institute of Nuclear Physics (INFN) Section of Pavia, via Bassi 6, 27100 Pavia (Italy); Ballarini, F.; Bortolussi, S. [University of Pavia, Department of Nuclear and Theoretical Physics, via Bassi 6, 27100 Pavia (Italy)] [National Institute of Nuclear Physics (INFN) Section of Pavia, via Bassi 6, 27100 Pavia (Italy); Bruschi, P. [University of Pavia, Department of Nuclear and Theoretical Physics, via Bassi 6, 27100 Pavia (Italy); Stella, S. [University of Pavia, Department of Nuclear and Theoretical Physics, via Bassi 6, 27100 Pavia (Italy)] [National Institute of Nuclear Physics (INFN) Section of Pavia, via Bassi 6, 27100 Pavia (Italy); Geninatti, S.; Alberti, D.; Aime, S. [University of Torino, Chemistry Department, via Nizza 52, 10126 Torino (Italy); Altieri, S. [University of Pavia, Department of Nuclear and Theoretical Physics, via Bassi 6, 27100 Pavia (Italy)] [National Institute of Nuclear Physics (INFN) Section of Pavia, via Bassi 6, 27100 Pavia (Italy)

    2011-12-15

    To test the efficacy of a new {sup 10}B-vector compound, the B/Gd/LDL adduct synthesised at Torino University, in vivo irradiations of murine tumours are in progress at the TRIGA Mark II reactor of the Pavia University. A localised B16 melanoma tumour is generated in C57BL/6 mice and subsequently infused with the adduct. During the irradiation, the mouse will be put in a shield to protect the whole body except the tumour in the back-neck area. To optimise the treatment set-up, MCNP simulations were performed. A very simplified mouse model was built using MCNP geometry capabilities, as well as the geometry of the shield made of 99% {sup 10}B enriched boric acid. A hole in the shield is foreseen in correspondence of the back-neck region. Many configurations of the shield were tested in terms of neutron flux, dose distribution and mean induced activity in the tumour region and in the radiosensitive organs of the mouse. In the final set-up, up to five mice can be treated simultaneously in the reactor thermal column and the neutron fluence in the tumour region for 10 min of irradiation is of about 5 Multiplication-Sign 10{sup 12} cm{sup -2}.

  8. Security devices and experiment facilities at ENEA TRIGA RC-1 reactor

    International Nuclear Information System (INIS)

    Bianchi, P.; Festinesi, A.; Santoro, E.; Tardani, G.; Magli, M.; Reis, G.

    1990-01-01

    RC-1 TRIGA operating exercise staff has produced some auxiliary security devices. These are the neutron source automatic handling device, irradiated samples rabbit connection rotating rack, and auxiliary equipment for transferring hot fuel elements. The reactor electronic control instrumentation system includes various instrumentation channels, the operating capability of which must be verified by the licensee as per Italian regulations. In order to obtain automatic and repeatable operations, TEMAV designed and constructed a remotely-driven source transfer device, based on requirements, performance specifications and technical data supplied by ENEA-TIB. The pneumatic irradiating system for short lived materials allows extraction of radiated samples in a time no longer than 4 seconds. To optimize the system, both as to operability and health protection, a specific rotating rack for the connection of irradiated samples with pneumatic transfer (RABBIT) was produced. To permit 1 MW hot fuel element storage in pits it is necessary to remove hot 100 KW fuel elements and transfer them to a re-treatment plant. Feasibility studies showed the impossibility of using heavy trucks inside the reactor hall. To avoid problems trucks are left outside the reactor hall and only the PEGASO container is removed with a special device that runs on rails. Movement from Rail truck is assured by an electromotor driving pull device and security cable

  9. The neutron and gamma-ray dose characterization using the Monte Carlo method to study the feasibility of the Prompt Gamma Activation Analysis technique at IPR-R1 TRIGA reactor in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Guerra, Bruno T.; Soares, Alexandre L.; Grynberg, Suely E.; Menezes, Maria Angela B.C., E-mail: brunoteixeiraguerra@yahoo.com.br, E-mail: menezes@cdtn.br, E-mail: asleal@cdtn.br, E-mail: seg@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    The IPR-R1 is a reactor type TRIGA, Mark-I model, manufactured by the General Atomic Company and installed at Nuclear Technology Development Centre (CDTN) of Brazilian Nuclear Energy Commission (CNEN), in Belo Horizonte, Brazil. It is a light water moderated and cooled, graphite-reflected, open-pool type research reactor. IPR-R1 works at 100 kW but it will be briefly licensed to operate at 250 kW. It presents low power, low pressure, for application in research, training and radioisotopes production. The fuel is an alloy of zirconium hydride and uranium enriched at 20% in {sup 235}U. The Implementation of the PGNAA (Prompt Gamma Neutron Activation Analysis) Technical at the TRIGA IPR-R1 research reactor of the CDTN will significantly increase in the types of matrices analyzable. A project is underway in order to implement this technique in CDTN. In order of verified the feasibility of the PGNAA at the TRIGA reactor, the MCNP (Monte Carlo N-Particle) method is used to theoretical calculations. This paper presents the results of a preliminary study of the neutron and gamma-ray dose in the room where the reactor is located, in case of implementation of this technique in the IPR-R1. (author)

  10. The neutron and gamma-ray dose characterization using the Monte Carlo method to study the feasibility of the Prompt Gamma Activation Analysis technique at IPR-R1 TRIGA reactor in Brazil

    International Nuclear Information System (INIS)

    Guerra, Bruno T.; Soares, Alexandre L.; Grynberg, Suely E.; Menezes, Maria Angela B.C.

    2013-01-01

    The IPR-R1 is a reactor type TRIGA, Mark-I model, manufactured by the General Atomic Company and installed at Nuclear Technology Development Centre (CDTN) of Brazilian Nuclear Energy Commission (CNEN), in Belo Horizonte, Brazil. It is a light water moderated and cooled, graphite-reflected, open-pool type research reactor. IPR-R1 works at 100 kW but it will be briefly licensed to operate at 250 kW. It presents low power, low pressure, for application in research, training and radioisotopes production. The fuel is an alloy of zirconium hydride and uranium enriched at 20% in 235 U. The Implementation of the PGNAA (Prompt Gamma Neutron Activation Analysis) Technical at the TRIGA IPR-R1 research reactor of the CDTN will significantly increase in the types of matrices analyzable. A project is underway in order to implement this technique in CDTN. In order of verified the feasibility of the PGNAA at the TRIGA reactor, the MCNP (Monte Carlo N-Particle) method is used to theoretical calculations. This paper presents the results of a preliminary study of the neutron and gamma-ray dose in the room where the reactor is located, in case of implementation of this technique in the IPR-R1. (author)

  11. Design innovation and service works after twenty years operation period at the 250 kW TRIGA reactor

    International Nuclear Information System (INIS)

    Hammer, J.; Boeck, H.

    1986-01-01

    In 1967 the thermalizing column of the TRIGA Reactor Vienna which was originally composed of graphite blocks was converted to a cold neutron source and the empty experimental tank was covered with heavy concrete shielding blocks. Since during the last decade this cold neutron source was not used and possible disintegration and corrosion of this system was to be expected it was decided to remove this installation and to replace it with a new designed two component collimator to be used for neutron radiography. The replacement of the cold neutron source required close access to the reactor core, therefore due to radiation protection aspects all fuel elements had to be removed from the reactor pool. As a consequence this situation was used to inspect visually two beam tubes and the reactor tank and to replace the two electromechanical control rod drives. Further, a new purification circuit was installed, replacing the old bypass system. Many other reactor components or systems were improved and serviced as described

  12. RELAP5 model for TRIGA 14 MWt

    International Nuclear Information System (INIS)

    Negut, Gheorghe; Prisecaru, Ilie)

    2003-01-01

    The ICN TRIGA facility was commissioned at the beginning of 1980. Since that time the 14 MW Material Test Reactor was used extensively for various tests, experiments and basic research. There were provided a 100 kW loop and natural convection capsules to test CANDU type fuel and structural materials as Zircaloy as well as medical and industrial radioisotopes production facilities. The first load of High Enriched Uranium (HEU) fuel, mostly was exhausted and in the '90 there was necessary a replacement with Low Enriched Uranium (LEU) fuel. The original configuration of 29 HEU fuel bundles is now replaced with a HEU - LEU mixed core of 35 fuel bundles. This process involved the revision of Safety Analysis Report.The paper presents the analysis of Loss of Fluid Accident (LOFA) and the comparison with the results obtained during commissioning phase. A simple model of the TRIGA core was developed with the aid of RELAP5MOD3.2 code. The RELAP5 documented the flow reversal and natural convection establishment, and the model proved a useful and accurate instrument for thermal hydraulic analysis. Presented are the RELAP5 model for the TRIGA reactor and a LOFA accident analysis. The following results and conclusions concerning the LOFA tests with emergency pump off after 15 minutes and at start of the test are presented. In the first test TRIGA reactor is operated at the nominal power of 14 MW and the main pumps flow rate is 700 kg/sec. The main pumps are stopped and in 10 seconds the flow rate reaches 22 kg/sec, the emergency pump flow rate. The emergency pump is stopped after 15 minutes from the LOFA test initiation. The reactor is tripped by the low flow rate signal at the level of 473 kg/sec. The core flow is reversed after the 5 seconds and the core is cooled by natural convection. After 425 seconds from the LOFA initiation the residual power level is sufficiently low, so, the flow is reversed once again and the residual heat is removed by the emergency pump flow in

  13. Water chemical control of the TRIGA IPR-R1 reactor primary cooling system

    International Nuclear Information System (INIS)

    Auler, Lucia M.L.A; Chaves, Renata D.A.; Palmieri, Helena E.L.; Menezes, Maria Angela de B.C.; Oliveira, Paulo F.; Kastner, Geraldo F.; Damazio, Ilza; Fagundes, Oliene dos R.; Cintra, Maria Olivia C.; Andrade, Geraldo V. de; Amaral, Angela M.; Franco, Milton B.; Fortes, Flavio; Gomes, Nilton Carlos; Vidal, Andrea; Maretti Junior, Fausto; Knupp, Eliana A.N.; Souza, Wagner de; Guedes, Joao B.; Furtado, Renato C.S.

    2013-01-01

    The TRIGA Mark I IPR-R1 reactor located at CDTN/CNEN has been in operation and contributed to research and with services to society since 1960. Is has been used in several activities such as nuclear power plant operation, graduate and post-graduate training courses, isotope production, and as an analytical irradiation tool of different types of samples. Among the several structural and operational safety requirements is the chemical quality control of the primary circuit cooling water. The aim of this work was to check the cooling water quality from the pool reactor. A water sampling plan was proposed (May, 2011 - June, 2012) and presents the results obtained in this period. The natural radioactivity level as gross alpha and gross beta activity and other chemical parameters (pH and electric conductivity) of the samples were analyzed. Some instrumental techniques were used: potentiometric methods (pH), conductometric methods (electrical conductivity, EC) and gross α and gross β proportional counting system). (author)

  14. Neutron spectra in two beam ports of a TRIGA Mark III reactor with HEU fuel

    International Nuclear Information System (INIS)

    Vega C, H. R.; Hernandez D, V. M.; Paredes G, L.; Aguilar, F.

    2012-10-01

    Before to change the HEU for Leu fuel of the ININ's TRIGA Mark III nuclear reactor the neutron spectra were measured in two beam ports using 5 and 10 W. Measurements were carried out in a tangential and a radial beam port using a Bonner sphere spectrometer. It was found that neutron spectra are different in the beam ports, in radial beam port the amplitude of thermal and fast neutrons are approximately the same while, in the tangential beam port thermal neutron peak is dominant. In the radial beam port the fluence-to-ambient dose equivalent factors are 131±11 and 124±10 p Sv-cm 2 for 5 and 10 W respectively while in the tangential beam port the fluence-to-ambient dose equivalent factor is 55±4 p Sv-cm 2 for 10 W. (Author)

  15. Characterization of the neutron flux in the Hohlraum of the thermal column of the TRIGA Mark III reactor of the ININ; Caracterizacion del flujo neutronico en el Hohlraum de la columna termica del reactor TRIGA Mark III del ININ

    Energy Technology Data Exchange (ETDEWEB)

    Delfin L, A.; Palacios, J.C.; Alonso, G. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: adl@nuclear.inin.mx

    2006-07-01

    Knowing the magnitude of the neutron flux in the reactor irradiation facilities, is so much importance for the operation of the same one, like for the investigation developing. Particularly, knowing with certain precision the spectrum and the neutron flux in the different positions of irradiation of a reactor, it is essential for the evaluation of the results obtained for a certain irradiation experiment. The TRIGA Mark III reactor account with irradiation facilities designed to carry out experimentation, where the reactor is used like an intense neutron source and gamma radiation, what allows to make irradiations of samples or equipment in radiation fields with components and diverse levels in the different facilities, one of these irradiation facilities is the Thermal Column where the Hohlraum is. In this work it was carried out a characterization of the neutron flux inside the 'Hohlraum' of the irradiation facility Thermal Column of the TRIGA Mark III reactor of the Nuclear Center of Mexico to 1 MW of power. It was determined the sub cadmic neutron flux and the epi cadmic by means of the neutron activation technique of thin sheets of gold. The maps of the distribution of the neutron flux for both energy groups in three different positions inside the 'Hohlraum' are presented, these maps were obtained by means of the irradiation of undressed thin activation sheets of gold and covered with cadmium in arrangements of 10 x 12, located parallel to 11.5 cm, 40.5 cm and 70.5 cm to the internal wall of graphite of the installation in inverse address to the position of the reactor core. Starting from the obtained values of neutron flux it was found that, for the same position of the surface of irradiation of the experimental arrangement, the relative differences among the values of neutron flux can be of 80%, and that the differences among different positions of the irradiation surfaces can vary until in a one order of magnitude. (Author)

  16. Safety Evakuation Of Triga-2000 Reactor Operation Viewed From Safety Culture

    International Nuclear Information System (INIS)

    Karliana, Itjeu

    2001-01-01

    The safety evaluation activities of TRIGA-2000 operation viewed from safety culture performed by questioners data collected from the operators and supervisor site of TRIGA-2000 P3TN, Bandung. There are 9 activity aspects surveyed, for instant to avail the policy of safety from their chairman, safety management, education and training, emergency aids planning, safety consultancy, accident information, safety analysis, safety devices, safety and occupational health. The surveying undertaken by filling the questioner that containing of 9 activity aspects and 20 samples of employees. The safety evaluation results' of the operation personnel in TRIGA-2000 P3TN are good implemented by both the operators and supervisors should be improve and attention need to provide the equipment's. The education and training especially for safety refreshment must be performing

  17. Burn-up TRIGA Mark II benchmark experiment

    International Nuclear Information System (INIS)

    Persic, A.; Ravnik, M.; Zagar, T.

    1998-01-01

    Different reactor codes are used for calculations of reactor parameters. The accuracy of the programs is tested through comparison of the calculated values with the experimental results. Well-defined and accurately measured benchmarks are required. The experimental results of reactivity measurements, fuel element reactivity worth distribution and fuel-up measurements are presented in this paper. The experiments were performed with partly burnt reactor core. The experimental conditions were well defined, so that the results can be used as a burn-up benchmark test case for a TRIGA Mark II reactor calculations.(author)

  18. Real-Time Monitoring of Neutron Capture Cross Section in the IPR-R1 TRIGA Research Reactor as a Fuel Temperature Function

    Energy Technology Data Exchange (ETDEWEB)

    Palma, D.A.P. [Comissao Nacional de Energia Nuclear, CNEN, General Severiano Street, 90, 22290-901, Rio de Janeiro (Brazil); Mesquita, A.Z.; Souza, R.M.G.P. [Comissao Nacional de Energia Nuclear, CNEN/CDTN, Av. Presidente Antonio Carlos, 6627, 31270-901, Belo Horizonte (Brazil); Martinez, A.S. [Programa de Engenharia Nuclear, COPPE/UFRJ, Av. Horacio Macedo, 2030, Bloco G, 21941- 914, Rio de Janeiro (Brazil)

    2011-07-01

    Nuclear reactor operators have to monitor the behaviour of different nuclear and design parameters that vary in time to ensure the operating safety of the reactor. In recent years several operating parameters for the IPR-R1 TRIGA research reactor were monitored and indicated in real-time by the data acquisition system developed for the reactor, with all the data being stored in a hard disk in the data acquisition computer, to build in this way a database. The goal of this work is to insert in the set of parameters already collected the neutron capture cross sections for the fuel, from the power and temperature numbers obtained in real-time. The experimental data was obtained by using a fuel element instrumented with temperature sensors, located in the core of the IPR-R1 TRIGA research reactor at the CDTN - Centre for Development of Nuclear. This information is useful for the continuous monitoring of the reaction rate in neutron capture. For that, a new analytical formulation is used for the Doppler broadening function proposed by Palma and Martinez which is free from special functions in its functional form and with easy computing implementation. The results obtained were satisfactory from the standpoint of accuracy in comparison with the numerical reference method and indicate that it is possible to carry out real-time monitoring of the neutron capture cross section in the fuel. (author)

  19. Fabrication and Testing of a Modular Micro-Pocket Fission Detector Instrumentation System for Test Nuclear Reactors

    Science.gov (United States)

    Reichenberger, Michael A.; Nichols, Daniel M.; Stevenson, Sarah R.; Swope, Tanner M.; Hilger, Caden W.; Roberts, Jeremy A.; Unruh, Troy C.; McGregor, Douglas S.

    2018-01-01

    Advancements in nuclear reactor core modeling and computational capability have encouraged further development of in-core neutron sensors. Measurement of the neutron-flux distribution within the reactor core provides a more complete understanding of the operating conditions in the reactor than typical ex-core sensors. Micro-Pocket Fission Detectors have been developed and tested previously but have been limited to single-node operation and have utilized highly specialized designs. The development of a widely deployable, multi-node Micro-Pocket Fission Detector assembly will enhance nuclear research capabilities. A modular, four-node Micro-Pocket Fission Detector array was designed, fabricated, and tested at Kansas State University. The array was constructed from materials that do not significantly perturb the neutron flux in the reactor core. All four sensor nodes were equally spaced axially in the array to span the fuel-region of the reactor core. The array was filled with neon gas, serving as an ionization medium in the small cavities of the Micro-Pocket Fission Detectors. The modular design of the instrument facilitates the testing and deployment of numerous sensor arrays. The unified design drastically improved device ruggedness and simplified construction from previous designs. Five 8-mm penetrations in the upper grid plate of the Kansas State University TRIGA Mk. II research nuclear reactor were utilized to deploy the array between fuel elements in the core. The Micro-Pocket Fission Detector array was coupled to an electronic support system which has been specially developed to support pulse-mode operation. The Micro-Pocket Fission Detector array composed of four sensors was used to monitor local neutron flux at a constant reactor power of 100 kWth at different axial locations simultaneously. The array was positioned at five different radial locations within the core to emulate the deployment of multiple arrays and develop a 2-dimensional measurement of

  20. Conceptual design of reactor TRIGA PUSPATI (RTP) spent fuel pool cooling system

    International Nuclear Information System (INIS)

    Tonny Lanyau; Mazleha Maskin; Mohd Fazli Zakaria; Mohmammad Suhaimi Kassim; Ahmad Nabil Abdul Rahim; Phongsakorn Prak Tom; Mohd Fairus Abdul Farid; Mohd Huzair Hussain

    2012-01-01

    After undergo about 30 years of safe operation, Reactor TRIGA PUSPATI (RTP) was planned to be upgraded to ensure continuous operation at optimum safety condition. In the meantime, upgrading is essential to get higher flux to diversify the reactor utilization. Spent fuel pool is needed for temporary storage of the irradiated fuel before sending it back to original country for reprocessing, reuse after the upgrading accomplished or final disposal. The irradiated fuel elements need to be secure physically with continuous cooling to ensure the safety of the fuels itself. The decay heat probably still exist even though the fuel elements not in the reactor core. Therefore, appropriate cooling is required to remove the heat produced by decay of the fission product in the irradiated fuel element. The design of spent fuel pool cooling system (SFPCS) was come to mind in order to provide the sufficient cooling to the irradiated fuel elements and also as a shielding. The spent fuel pool cooling system generally equipped with pumps, heat exchanger, water storage tank, valve and piping. The design of the system is based on criteria of the primary cooling system. This paper provides the conceptual design of the spent fuel cooling system. (author)