WorldWideScience

Sample records for rigorous quantitative methods

  1. Mixing quantitative with qualitative methods

    DEFF Research Database (Denmark)

    Morrison, Ann; Viller, Stephen; Heck, Tamara

    2017-01-01

    with or are considering, researching, or working with both quantitative and qualitative evaluation methods (in academia or industry), join us in this workshop. In particular, we look at adding quantitative to qualitative methods to build a whole picture of user experience. We see a need to discuss both quantitative...... and qualitative research because there is often a perceived lack of understanding of the rigor involved in each. The workshop will result in a White Paper on the latest developments in this field, within Australia and comparative with international work. We anticipate sharing submissions and workshop outcomes...

  2. Comparison of rigorous modelling of different structure profiles on photomasks for quantitative linewidth measurements by means of UV- or DUV-optical microscopy

    Science.gov (United States)

    Ehret, Gerd; Bodermann, Bernd; Woehler, Martin

    2007-06-01

    The optical microscopy is an important instrument for dimensional characterisation or calibration of micro- and nanostructures, e.g. chrome structures on photomasks. In comparison to scanning electron microscopy (possible contamination of the sample) and atomic force microscopy (slow, risk of damage) optical microscopy is a fast and non destructive metrology method. The precise quantitative determination of the linewidth from the microscope image is, however, only possible by knowledge of the geometry of the structures and their consideration in the optical modelling. We compared two different rigorous model approaches, the Rigorous Coupled Wave Analysis (RCWA) and the Finite Elements Method (FEM) for modelling of structures with different edge angles, linewidths, line to space ratios and polarisations. The RCWA method can adapt inclined edges profiles only by a staircase approximation leading to increased modelling errors of the RCWA method. Even today's sophisticated rigorous methods still show problems with TM-polarisation. Therefore both rigorous methods are compared in terms of their convergence for TE and TM- polarisation. Beyond that also the influence of typical illumination wavelengths (365 nm, 248 nm and 193 nm) on the microscope images and their contribution to the measuring uncertainty budget will be discussed.

  3. A study into first-year engineering education success using a rigorous mixed methods approach

    DEFF Research Database (Denmark)

    van den Bogaard, M.E.D.; de Graaff, Erik; Verbraek, Alexander

    2015-01-01

    The aim of this paper is to combine qualitative and quantitative research methods into rigorous research into student success. Research methods have weaknesses that can be overcome by clever combinations. In this paper we use a situated study into student success as an example of how methods...... using statistical techniques. The main elements of the model were student behaviour and student disposition, which were influenced by the students’ perceptions of the education environment. The outcomes of the qualitative studies were useful in interpreting the outcomes of the structural equation...

  4. Recent Development in Rigorous Computational Methods in Dynamical Systems

    OpenAIRE

    Arai, Zin; Kokubu, Hiroshi; Pilarczyk, Paweł

    2009-01-01

    We highlight selected results of recent development in the area of rigorous computations which use interval arithmetic to analyse dynamical systems. We describe general ideas and selected details of different ways of approach and we provide specific sample applications to illustrate the effectiveness of these methods. The emphasis is put on a topological approach, which combined with rigorous calculations provides a broad range of new methods that yield mathematically rel...

  5. Using grounded theory as a method for rigorously reviewing literature

    NARCIS (Netherlands)

    Wolfswinkel, J.; Furtmueller-Ettinger, Elfriede; Wilderom, Celeste P.M.

    2013-01-01

    This paper offers guidance to conducting a rigorous literature review. We present this in the form of a five-stage process in which we use Grounded Theory as a method. We first probe the guidelines explicated by Webster and Watson, and then we show the added value of Grounded Theory for rigorously

  6. Methodological Reporting in Qualitative, Quantitative, and Mixed Methods Health Services Research Articles

    Science.gov (United States)

    Wisdom, Jennifer P; Cavaleri, Mary A; Onwuegbuzie, Anthony J; Green, Carla A

    2012-01-01

    Objectives Methodologically sound mixed methods research can improve our understanding of health services by providing a more comprehensive picture of health services than either method can alone. This study describes the frequency of mixed methods in published health services research and compares the presence of methodological components indicative of rigorous approaches across mixed methods, qualitative, and quantitative articles. Data Sources All empirical articles (n = 1,651) published between 2003 and 2007 from four top-ranked health services journals. Study Design All mixed methods articles (n = 47) and random samples of qualitative and quantitative articles were evaluated to identify reporting of key components indicating rigor for each method, based on accepted standards for evaluating the quality of research reports (e.g., use of p-values in quantitative reports, description of context in qualitative reports, and integration in mixed method reports). We used chi-square tests to evaluate differences between article types for each component. Principal Findings Mixed methods articles comprised 2.85 percent (n = 47) of empirical articles, quantitative articles 90.98 percent (n = 1,502), and qualitative articles 6.18 percent (n = 102). There was a statistically significant difference (χ2(1) = 12.20, p = .0005, Cramer's V = 0.09, odds ratio = 1.49 [95% confidence interval = 1,27, 1.74]) in the proportion of quantitative methodological components present in mixed methods compared to quantitative papers (21.94 versus 47.07 percent, respectively) but no statistically significant difference (χ2(1) = 0.02, p = .89, Cramer's V = 0.01) in the proportion of qualitative methodological components in mixed methods compared to qualitative papers (21.34 versus 25.47 percent, respectively). Conclusion Few published health services research articles use mixed methods. The frequency of key methodological components is variable. Suggestions are provided to increase the

  7. The MIXED framework: A novel approach to evaluating mixed-methods rigor.

    Science.gov (United States)

    Eckhardt, Ann L; DeVon, Holli A

    2017-10-01

    Evaluation of rigor in mixed-methods (MM) research is a persistent challenge due to the combination of inconsistent philosophical paradigms, the use of multiple research methods which require different skill sets, and the need to combine research at different points in the research process. Researchers have proposed a variety of ways to thoroughly evaluate MM research, but each method fails to provide a framework that is useful for the consumer of research. In contrast, the MIXED framework is meant to bridge the gap between an academic exercise and practical assessment of a published work. The MIXED framework (methods, inference, expertise, evaluation, and design) borrows from previously published frameworks to create a useful tool for the evaluation of a published study. The MIXED framework uses an experimental eight-item scale that allows for comprehensive integrated assessment of MM rigor in published manuscripts. Mixed methods are becoming increasingly prevalent in nursing and healthcare research requiring researchers and consumers to address issues unique to MM such as evaluation of rigor. © 2017 John Wiley & Sons Ltd.

  8. Methodological reporting in qualitative, quantitative, and mixed methods health services research articles.

    Science.gov (United States)

    Wisdom, Jennifer P; Cavaleri, Mary A; Onwuegbuzie, Anthony J; Green, Carla A

    2012-04-01

    Methodologically sound mixed methods research can improve our understanding of health services by providing a more comprehensive picture of health services than either method can alone. This study describes the frequency of mixed methods in published health services research and compares the presence of methodological components indicative of rigorous approaches across mixed methods, qualitative, and quantitative articles. All empirical articles (n = 1,651) published between 2003 and 2007 from four top-ranked health services journals. All mixed methods articles (n = 47) and random samples of qualitative and quantitative articles were evaluated to identify reporting of key components indicating rigor for each method, based on accepted standards for evaluating the quality of research reports (e.g., use of p-values in quantitative reports, description of context in qualitative reports, and integration in mixed method reports). We used chi-square tests to evaluate differences between article types for each component. Mixed methods articles comprised 2.85 percent (n = 47) of empirical articles, quantitative articles 90.98 percent (n = 1,502), and qualitative articles 6.18 percent (n = 102). There was a statistically significant difference (χ(2) (1) = 12.20, p = .0005, Cramer's V = 0.09, odds ratio = 1.49 [95% confidence interval = 1,27, 1.74]) in the proportion of quantitative methodological components present in mixed methods compared to quantitative papers (21.94 versus 47.07 percent, respectively) but no statistically significant difference (χ(2) (1) = 0.02, p = .89, Cramer's V = 0.01) in the proportion of qualitative methodological components in mixed methods compared to qualitative papers (21.34 versus 25.47 percent, respectively). Few published health services research articles use mixed methods. The frequency of key methodological components is variable. Suggestions are provided to increase the transparency of mixed methods studies and

  9. Quantitative imaging biomarkers: a review of statistical methods for technical performance assessment.

    Science.gov (United States)

    Raunig, David L; McShane, Lisa M; Pennello, Gene; Gatsonis, Constantine; Carson, Paul L; Voyvodic, James T; Wahl, Richard L; Kurland, Brenda F; Schwarz, Adam J; Gönen, Mithat; Zahlmann, Gudrun; Kondratovich, Marina V; O'Donnell, Kevin; Petrick, Nicholas; Cole, Patricia E; Garra, Brian; Sullivan, Daniel C

    2015-02-01

    Technological developments and greater rigor in the quantitative measurement of biological features in medical images have given rise to an increased interest in using quantitative imaging biomarkers to measure changes in these features. Critical to the performance of a quantitative imaging biomarker in preclinical or clinical settings are three primary metrology areas of interest: measurement linearity and bias, repeatability, and the ability to consistently reproduce equivalent results when conditions change, as would be expected in any clinical trial. Unfortunately, performance studies to date differ greatly in designs, analysis method, and metrics used to assess a quantitative imaging biomarker for clinical use. It is therefore difficult or not possible to integrate results from different studies or to use reported results to design studies. The Radiological Society of North America and the Quantitative Imaging Biomarker Alliance with technical, radiological, and statistical experts developed a set of technical performance analysis methods, metrics, and study designs that provide terminology, metrics, and methods consistent with widely accepted metrological standards. This document provides a consistent framework for the conduct and evaluation of quantitative imaging biomarker performance studies so that results from multiple studies can be compared, contrasted, or combined. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  10. Comparison of two methods of quantitation in human studies of biodistribution and radiation dosimetry

    International Nuclear Information System (INIS)

    Smith, T.

    1992-01-01

    A simple method of quantitating organ radioactivity content for dosimetry purposes based on relationships between organ count rate and the initial whole body count rate, has been compared with a more rigorous method of absolute quantitation using a transmission scanning technique. Comparisons were on the basis of organ uptake (% administered activity) and resultant organ radiation doses (mGy MBq -1 ) in 6 normal male volunteers given a 99 Tc m -labelled myocardial perfusion imaging agent intravenously at rest and following exercise. In these studies, estimates of individual organ uptakes by the simple method were in error by between +24 and -16% compared with the more accurate method. However, errors on organ dose values were somewhat less and the effective dose was correct to within 3%. (Author)

  11. How to Map Theory: Reliable Methods Are Fruitless Without Rigorous Theory.

    Science.gov (United States)

    Gray, Kurt

    2017-09-01

    Good science requires both reliable methods and rigorous theory. Theory allows us to build a unified structure of knowledge, to connect the dots of individual studies and reveal the bigger picture. Some have criticized the proliferation of pet "Theories," but generic "theory" is essential to healthy science, because questions of theory are ultimately those of validity. Although reliable methods and rigorous theory are synergistic, Action Identification suggests psychological tension between them: The more we focus on methodological details, the less we notice the broader connections. Therefore, psychology needs to supplement training in methods (how to design studies and analyze data) with training in theory (how to connect studies and synthesize ideas). This article provides a technique for visually outlining theory: theory mapping. Theory mapping contains five elements, which are illustrated with moral judgment and with cars. Also included are 15 additional theory maps provided by experts in emotion, culture, priming, power, stress, ideology, morality, marketing, decision-making, and more (see all at theorymaps.org ). Theory mapping provides both precision and synthesis, which helps to resolve arguments, prevent redundancies, assess the theoretical contribution of papers, and evaluate the likelihood of surprising effects.

  12. Optimal correction and design parameter search by modern methods of rigorous global optimization

    International Nuclear Information System (INIS)

    Makino, K.; Berz, M.

    2011-01-01

    Frequently the design of schemes for correction of aberrations or the determination of possible operating ranges for beamlines and cells in synchrotrons exhibit multitudes of possibilities for their correction, usually appearing in disconnected regions of parameter space which cannot be directly qualified by analytical means. In such cases, frequently an abundance of optimization runs are carried out, each of which determines a local minimum depending on the specific chosen initial conditions. Practical solutions are then obtained through an often extended interplay of experienced manual adjustment of certain suitable parameters and local searches by varying other parameters. However, in a formal sense this problem can be viewed as a global optimization problem, i.e. the determination of all solutions within a certain range of parameters that lead to a specific optimum. For example, it may be of interest to find all possible settings of multiple quadrupoles that can achieve imaging; or to find ahead of time all possible settings that achieve a particular tune; or to find all possible manners to adjust nonlinear parameters to achieve correction of high order aberrations. These tasks can easily be phrased in terms of such an optimization problem; but while mathematically this formulation is often straightforward, it has been common belief that it is of limited practical value since the resulting optimization problem cannot usually be solved. However, recent significant advances in modern methods of rigorous global optimization make these methods feasible for optics design for the first time. The key ideas of the method lie in an interplay of rigorous local underestimators of the objective functions, and by using the underestimators to rigorously iteratively eliminate regions that lie above already known upper bounds of the minima, in what is commonly known as a branch-and-bound approach. Recent enhancements of the Differential Algebraic methods used in particle

  13. Rigor in Qualitative Supply Chain Management Research

    DEFF Research Database (Denmark)

    Goffin, Keith; Raja, Jawwad; Claes, Björn

    2012-01-01

    , reliability, and theoretical saturation. Originality/value – It is the authors' contention that the addition of the repertory grid technique to the toolset of methods used by logistics and supply chain management researchers can only enhance insights and the building of robust theories. Qualitative studies......Purpose – The purpose of this paper is to share the authors' experiences of using the repertory grid technique in two supply chain management studies. The paper aims to demonstrate how the two studies provided insights into how qualitative techniques such as the repertory grid can be made more...... rigorous than in the past, and how results can be generated that are inaccessible using quantitative methods. Design/methodology/approach – This paper presents two studies undertaken using the repertory grid technique to illustrate its application in supply chain management research. Findings – The paper...

  14. [Adequate application of quantitative and qualitative statistic analytic methods in acupuncture clinical trials].

    Science.gov (United States)

    Tan, Ming T; Liu, Jian-ping; Lao, Lixing

    2012-08-01

    Recently, proper use of the statistical methods in traditional Chinese medicine (TCM) randomized controlled trials (RCTs) has received increased attention. Statistical inference based on hypothesis testing is the foundation of clinical trials and evidence-based medicine. In this article, the authors described the methodological differences between literature published in Chinese and Western journals in the design and analysis of acupuncture RCTs and the application of basic statistical principles. In China, qualitative analysis method has been widely used in acupuncture and TCM clinical trials, while the between-group quantitative analysis methods on clinical symptom scores are commonly used in the West. The evidence for and against these analytical differences were discussed based on the data of RCTs assessing acupuncture for pain relief. The authors concluded that although both methods have their unique advantages, quantitative analysis should be used as the primary analysis while qualitative analysis can be a secondary criterion for analysis. The purpose of this paper is to inspire further discussion of such special issues in clinical research design and thus contribute to the increased scientific rigor of TCM research.

  15. A CUMULATIVE MIGRATION METHOD FOR COMPUTING RIGOROUS TRANSPORT CROSS SECTIONS AND DIFFUSION COEFFICIENTS FOR LWR LATTICES WITH MONTE CARLO

    Energy Technology Data Exchange (ETDEWEB)

    Zhaoyuan Liu; Kord Smith; Benoit Forget; Javier Ortensi

    2016-05-01

    A new method for computing homogenized assembly neutron transport cross sections and dif- fusion coefficients that is both rigorous and computationally efficient is proposed in this paper. In the limit of a homogeneous hydrogen slab, the new method is equivalent to the long-used, and only-recently-published CASMO transport method. The rigorous method is used to demonstrate the sources of inaccuracy in the commonly applied “out-scatter” transport correction. It is also demonstrated that the newly developed method is directly applicable to lattice calculations per- formed by Monte Carlo and is capable of computing rigorous homogenized transport cross sections for arbitrarily heterogeneous lattices. Comparisons of several common transport cross section ap- proximations are presented for a simple problem of infinite medium hydrogen. The new method has also been applied in computing 2-group diffusion data for an actual PWR lattice from BEAVRS benchmark.

  16. Experimental evaluation of rigor mortis. VI. Effect of various causes of death on the evolution of rigor mortis.

    Science.gov (United States)

    Krompecher, T; Bergerioux, C; Brandt-Casadevall, C; Gujer, H R

    1983-07-01

    The evolution of rigor mortis was studied in cases of nitrogen asphyxia, drowning and strangulation, as well as in fatal intoxications due to strychnine, carbon monoxide and curariform drugs, using a modified method of measurement. Our experiments demonstrated that: (1) Strychnine intoxication hastens the onset and passing of rigor mortis. (2) CO intoxication delays the resolution of rigor mortis. (3) The intensity of rigor may vary depending upon the cause of death. (4) If the stage of rigidity is to be used to estimate the time of death, it is necessary: (a) to perform a succession of objective measurements of rigor mortis intensity; and (b) to verify the eventual presence of factors that could play a role in the modification of its development.

  17. A Generalized Method for the Comparable and Rigorous Calculation of the Polytropic Efficiencies of Turbocompressors

    Science.gov (United States)

    Dimitrakopoulos, Panagiotis

    2018-03-01

    The calculation of polytropic efficiencies is a very important task, especially during the development of new compression units, like compressor impellers, stages and stage groups. Such calculations are also crucial for the determination of the performance of a whole compressor. As processors and computational capacities have substantially been improved in the last years, the need for a new, rigorous, robust, accurate and at the same time standardized method merged, regarding the computation of the polytropic efficiencies, especially based on thermodynamics of real gases. The proposed method is based on the rigorous definition of the polytropic efficiency. The input consists of pressure and temperature values at the end points of the compression path (suction and discharge), for a given working fluid. The average relative error for the studied cases was 0.536 %. Thus, this high-accuracy method is proposed for efficiency calculations related with turbocompressors and their compression units, especially when they are operating at high power levels, for example in jet engines and high-power plants.

  18. Scientific rigor through videogames.

    Science.gov (United States)

    Treuille, Adrien; Das, Rhiju

    2014-11-01

    Hypothesis-driven experimentation - the scientific method - can be subverted by fraud, irreproducibility, and lack of rigorous predictive tests. A robust solution to these problems may be the 'massive open laboratory' model, recently embodied in the internet-scale videogame EteRNA. Deploying similar platforms throughout biology could enforce the scientific method more broadly. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Tenderness of pre- and post rigor lamb longissimus muscle.

    Science.gov (United States)

    Geesink, Geert; Sujang, Sadi; Koohmaraie, Mohammad

    2011-08-01

    Lamb longissimus muscle (n=6) sections were cooked at different times post mortem (prerigor, at rigor, 1dayp.m., and 7 days p.m.) using two cooking methods. Using a boiling waterbath, samples were either cooked to a core temperature of 70 °C or boiled for 3h. The latter method was meant to reflect the traditional cooking method employed in countries where preparation of prerigor meat is practiced. The time postmortem at which the meat was prepared had a large effect on the tenderness (shear force) of the meat (PCooking prerigor and at rigor meat to 70 °C resulted in higher shear force values than their post rigor counterparts at 1 and 7 days p.m. (9.4 and 9.6 vs. 7.2 and 3.7 kg, respectively). The differences in tenderness between the treatment groups could be largely explained by a difference in contraction status of the meat after cooking and the effect of ageing on tenderness. Cooking pre and at rigor meat resulted in severe muscle contraction as evidenced by the differences in sarcomere length of the cooked samples. Mean sarcomere lengths in the pre and at rigor samples ranged from 1.05 to 1.20 μm. The mean sarcomere length in the post rigor samples was 1.44 μm. Cooking for 3 h at 100 °C did improve the tenderness of pre and at rigor prepared meat as compared to cooking to 70 °C, but not to the extent that ageing did. It is concluded that additional intervention methods are needed to improve the tenderness of prerigor cooked meat. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Putrefactive rigor: apparent rigor mortis due to gas distension.

    Science.gov (United States)

    Gill, James R; Landi, Kristen

    2011-09-01

    Artifacts due to decomposition may cause confusion for the initial death investigator, leading to an incorrect suspicion of foul play. Putrefaction is a microorganism-driven process that results in foul odor, skin discoloration, purge, and bloating. Various decompositional gases including methane, hydrogen sulfide, carbon dioxide, and hydrogen will cause the body to bloat. We describe 3 instances of putrefactive gas distension (bloating) that produced the appearance of inappropriate rigor, so-called putrefactive rigor. These gases may distend the body to an extent that the extremities extend and lose contact with their underlying support surface. The medicolegal investigator must recognize that this is not true rigor mortis and the body was not necessarily moved after death for this gravity-defying position to occur.

  1. A new method for deriving rigorous results on ππ scattering

    International Nuclear Information System (INIS)

    Caprini, I.; Dita, P.

    1979-06-01

    We develop a new approach to the problem of constraining the ππ scattering amplitudes by means of the axiomatically proved properties of unitarity, analyticity and crossing symmetry. The method is based on the solution of an extremal problem on a convex set of analytic functions and provides a global description of the domain of values taken by any finite number of partial waves at an arbitrary set of unphysical energies, compatible with unitarity, the bounds at complex energies derived from generalized dispersion relations and the crossing integral relations. From this doma domain we obtain new absolute bounds for the amplitudes as well as rigorous correlations between the values of various partial waves. (author)

  2. Experimental evaluation of rigor mortis. III. Comparative study of the evolution of rigor mortis in different sized muscle groups in rats.

    Science.gov (United States)

    Krompecher, T; Fryc, O

    1978-01-01

    The use of new methods and an appropriate apparatus has allowed us to make successive measurements of rigor mortis and a study of its evolution in the rat. By a comparative examination on the front and hind limbs, we have determined the following: (1) The muscular mass of the hind limbs is 2.89 times greater than that of the front limbs. (2) In the initial phase rigor mortis is more pronounced in the front limbs. (3) The front and hind limbs reach maximum rigor mortis at the same time and this state is maintained for 2 hours. (4) Resolution of rigor mortis is accelerated in the front limbs during the initial phase, but both front and hind limbs reach complete resolution at the same time.

  3. Application of the rigorous method to x-ray and neutron beam scattering on rough surfaces

    International Nuclear Information System (INIS)

    Goray, Leonid I.

    2010-01-01

    The paper presents a comprehensive numerical analysis of x-ray and neutron scattering from finite-conducting rough surfaces which is performed in the frame of the boundary integral equation method in a rigorous formulation for high ratios of characteristic dimension to wavelength. The single integral equation obtained involves boundary integrals of the single and double layer potentials. A more general treatment of the energy conservation law applicable to absorption gratings and rough mirrors is considered. In order to compute the scattering intensity of rough surfaces using the forward electromagnetic solver, Monte Carlo simulation is employed to average the deterministic diffraction grating efficiency due to individual surfaces over an ensemble of realizations. Some rules appropriate for numerical implementation of the theory at small wavelength-to-period ratios are presented. The difference between the rigorous approach and approximations can be clearly seen in specular reflectances of Au mirrors with different roughness parameters at wavelengths where grazing incidence occurs at close to or larger than the critical angle. This difference may give rise to wrong estimates of rms roughness and correlation length if they are obtained by comparing experimental data with calculations. Besides, the rigorous approach permits taking into account any known roughness statistics and allows exact computation of diffuse scattering.

  4. A new look at the statistical assessment of approximate and rigorous methods for the estimation of stabilized formation temperatures in geothermal and petroleum wells

    International Nuclear Information System (INIS)

    Espinoza-Ojeda, O M; Santoyo, E; Andaverde, J

    2011-01-01

    Approximate and rigorous solutions of seven heat transfer models were statistically examined, for the first time, to estimate stabilized formation temperatures (SFT) of geothermal and petroleum boreholes. Constant linear and cylindrical heat source models were used to describe the heat flow (either conductive or conductive/convective) involved during a borehole drilling. A comprehensive statistical assessment of the major error sources associated with the use of these models was carried out. The mathematical methods (based on approximate and rigorous solutions of heat transfer models) were thoroughly examined by using four statistical analyses: (i) the use of linear and quadratic regression models to infer the SFT; (ii) the application of statistical tests of linearity to evaluate the actual relationship between bottom-hole temperatures and time function data for each selected method; (iii) the comparative analysis of SFT estimates between the approximate and rigorous predictions of each analytical method using a β ratio parameter to evaluate the similarity of both solutions, and (iv) the evaluation of accuracy in each method using statistical tests of significance, and deviation percentages between 'true' formation temperatures and SFT estimates (predicted from approximate and rigorous solutions). The present study also enabled us to determine the sensitivity parameters that should be considered for a reliable calculation of SFT, as well as to define the main physical and mathematical constraints where the approximate and rigorous methods could provide consistent SFT estimates

  5. A no-gold-standard technique for objective assessment of quantitative nuclear-medicine imaging methods.

    Science.gov (United States)

    Jha, Abhinav K; Caffo, Brian; Frey, Eric C

    2016-04-07

    The objective optimization and evaluation of nuclear-medicine quantitative imaging methods using patient data is highly desirable but often hindered by the lack of a gold standard. Previously, a regression-without-truth (RWT) approach has been proposed for evaluating quantitative imaging methods in the absence of a gold standard, but this approach implicitly assumes that bounds on the distribution of true values are known. Several quantitative imaging methods in nuclear-medicine imaging measure parameters where these bounds are not known, such as the activity concentration in an organ or the volume of a tumor. We extended upon the RWT approach to develop a no-gold-standard (NGS) technique for objectively evaluating such quantitative nuclear-medicine imaging methods with patient data in the absence of any ground truth. Using the parameters estimated with the NGS technique, a figure of merit, the noise-to-slope ratio (NSR), can be computed, which can rank the methods on the basis of precision. An issue with NGS evaluation techniques is the requirement of a large number of patient studies. To reduce this requirement, the proposed method explored the use of multiple quantitative measurements from the same patient, such as the activity concentration values from different organs in the same patient. The proposed technique was evaluated using rigorous numerical experiments and using data from realistic simulation studies. The numerical experiments demonstrated that the NSR was estimated accurately using the proposed NGS technique when the bounds on the distribution of true values were not precisely known, thus serving as a very reliable metric for ranking the methods on the basis of precision. In the realistic simulation study, the NGS technique was used to rank reconstruction methods for quantitative single-photon emission computed tomography (SPECT) based on their performance on the task of estimating the mean activity concentration within a known volume of interest

  6. A no-gold-standard technique for objective assessment of quantitative nuclear-medicine imaging methods

    International Nuclear Information System (INIS)

    Jha, Abhinav K; Frey, Eric C; Caffo, Brian

    2016-01-01

    The objective optimization and evaluation of nuclear-medicine quantitative imaging methods using patient data is highly desirable but often hindered by the lack of a gold standard. Previously, a regression-without-truth (RWT) approach has been proposed for evaluating quantitative imaging methods in the absence of a gold standard, but this approach implicitly assumes that bounds on the distribution of true values are known. Several quantitative imaging methods in nuclear-medicine imaging measure parameters where these bounds are not known, such as the activity concentration in an organ or the volume of a tumor. We extended upon the RWT approach to develop a no-gold-standard (NGS) technique for objectively evaluating such quantitative nuclear-medicine imaging methods with patient data in the absence of any ground truth. Using the parameters estimated with the NGS technique, a figure of merit, the noise-to-slope ratio (NSR), can be computed, which can rank the methods on the basis of precision. An issue with NGS evaluation techniques is the requirement of a large number of patient studies. To reduce this requirement, the proposed method explored the use of multiple quantitative measurements from the same patient, such as the activity concentration values from different organs in the same patient. The proposed technique was evaluated using rigorous numerical experiments and using data from realistic simulation studies. The numerical experiments demonstrated that the NSR was estimated accurately using the proposed NGS technique when the bounds on the distribution of true values were not precisely known, thus serving as a very reliable metric for ranking the methods on the basis of precision. In the realistic simulation study, the NGS technique was used to rank reconstruction methods for quantitative single-photon emission computed tomography (SPECT) based on their performance on the task of estimating the mean activity concentration within a known volume of interest

  7. [Methods of quantitative proteomics].

    Science.gov (United States)

    Kopylov, A T; Zgoda, V G

    2007-01-01

    In modern science proteomic analysis is inseparable from other fields of systemic biology. Possessing huge resources quantitative proteomics operates colossal information on molecular mechanisms of life. Advances in proteomics help researchers to solve complex problems of cell signaling, posttranslational modification, structure and functional homology of proteins, molecular diagnostics etc. More than 40 various methods have been developed in proteomics for quantitative analysis of proteins. Although each method is unique and has certain advantages and disadvantages all these use various isotope labels (tags). In this review we will consider the most popular and effective methods employing both chemical modifications of proteins and also metabolic and enzymatic methods of isotope labeling.

  8. PRO development: rigorous qualitative research as the crucial foundation.

    Science.gov (United States)

    Lasch, Kathryn Eilene; Marquis, Patrick; Vigneux, Marc; Abetz, Linda; Arnould, Benoit; Bayliss, Martha; Crawford, Bruce; Rosa, Kathleen

    2010-10-01

    Recently published articles have described criteria to assess qualitative research in the health field in general, but very few articles have delineated qualitative methods to be used in the development of Patient-Reported Outcomes (PROs). In fact, how PROs are developed with subject input through focus groups and interviews has been given relatively short shrift in the PRO literature when compared to the plethora of quantitative articles on the psychometric properties of PROs. If documented at all, most PRO validation articles give little for the reader to evaluate the content validity of the measures and the credibility and trustworthiness of the methods used to develop them. Increasingly, however, scientists and authorities want to be assured that PRO items and scales have meaning and relevance to subjects. This article was developed by an international, interdisciplinary group of psychologists, psychometricians, regulatory experts, a physician, and a sociologist. It presents rigorous and appropriate qualitative research methods for developing PROs with content validity. The approach described combines an overarching phenomenological theoretical framework with grounded theory data collection and analysis methods to yield PRO items and scales that have content validity.

  9. Quantitative planar thallium-201 stress scintigraphy: A critical evaluation of the method

    International Nuclear Information System (INIS)

    Wackers, F.J.; Fetterman, R.C.; Mattera, J.A.; Clements, J.P.

    1985-01-01

    The results of quantitative analysis of planar thallium- 201 stress scintigraphy are superior to those of visual analysis. The increased sensitivity for detection of coronary artery disease is associated with maintenance of specificity. Consequently, the authors believe that quantitative analysis is the state-of-the-art for planar 201 Tl stress scintigraphy. They emphasize that for reliable and reproducible results, rigorous quality control and strict adherence to a standardized imaging protocol are necessary. An important feature is clarity of display of computer data. In this experience, the most important feature for making quantitative analysis reliable and accessible for a broader user market is simultaneous display of the lower limits of normal with processed patient data. This provides a simple visual impression of the degree and extent of abnormal 201 Tl distribution and kinetics relative to the lower limit of normal

  10. Rigorous solution to Bargmann-Wigner equation for integer spin

    CERN Document Server

    Huang Shi Zhong; Wu Ning; Zheng Zhi Peng

    2002-01-01

    A rigorous method is developed to solve the Bargamann-Wigner equation for arbitrary integer spin in coordinate representation in a step by step way. The Bargmann-Wigner equation is first transformed to a form easier to solve, the new equations are then solved rigorously in coordinate representation, and the wave functions in a closed form are thus derived

  11. Studies on the estimation of the postmortem interval. 3. Rigor mortis (author's transl).

    Science.gov (United States)

    Suzutani, T; Ishibashi, H; Takatori, T

    1978-11-01

    The authors have devised a method for classifying rigor mortis into 10 types based on its appearance and strength in various parts of a cadaver. By applying the method to the findings of 436 cadavers which were subjected to medico-legal autopsies in our laboratory during the last 10 years, it has been demonstrated that the classifying method is effective for analyzing the phenomenon of onset, persistence and disappearance of rigor mortis statistically. The investigation of the relationship between each type of rigor mortis and the postmortem interval has demonstrated that rigor mortis may be utilized as a basis for estimating the postmortem interval but the values have greater deviation than those described in current textbooks.

  12. Rigor or Reliability and Validity in Qualitative Research: Perspectives, Strategies, Reconceptualization, and Recommendations.

    Science.gov (United States)

    Cypress, Brigitte S

    Issues are still raised even now in the 21st century by the persistent concern with achieving rigor in qualitative research. There is also a continuing debate about the analogous terms reliability and validity in naturalistic inquiries as opposed to quantitative investigations. This article presents the concept of rigor in qualitative research using a phenomenological study as an exemplar to further illustrate the process. Elaborating on epistemological and theoretical conceptualizations by Lincoln and Guba, strategies congruent with qualitative perspective for ensuring validity to establish the credibility of the study are described. A synthesis of the historical development of validity criteria evident in the literature during the years is explored. Recommendations are made for use of the term rigor instead of trustworthiness and the reconceptualization and renewed use of the concept of reliability and validity in qualitative research, that strategies for ensuring rigor must be built into the qualitative research process rather than evaluated only after the inquiry, and that qualitative researchers and students alike must be proactive and take responsibility in ensuring the rigor of a research study. The insights garnered here will move novice researchers and doctoral students to a better conceptual grasp of the complexity of reliability and validity and its ramifications for qualitative inquiry.

  13. Experimental evaluation of rigor mortis. V. Effect of various temperatures on the evolution of rigor mortis.

    Science.gov (United States)

    Krompecher, T

    1981-01-01

    Objective measurements were carried out to study the evolution of rigor mortis on rats at various temperatures. Our experiments showed that: (1) at 6 degrees C rigor mortis reaches full development between 48 and 60 hours post mortem, and is resolved at 168 hours post mortem; (2) at 24 degrees C rigor mortis reaches full development at 5 hours post mortem, and is resolved at 16 hours post mortem; (3) at 37 degrees C rigor mortis reaches full development at 3 hours post mortem, and is resolved at 6 hours post mortem; (4) the intensity of rigor mortis grows with increase in temperature (difference between values obtained at 24 degrees C and 37 degrees C); and (5) and 6 degrees C a "cold rigidity" was found, in addition to and independent of rigor mortis.

  14. Rigorous numerical modeling of scattering-type scanning near-field optical microscopy and spectroscopy

    Science.gov (United States)

    Chen, Xinzhong; Lo, Chiu Fan Bowen; Zheng, William; Hu, Hai; Dai, Qing; Liu, Mengkun

    2017-11-01

    Over the last decade, scattering-type scanning near-field optical microscopy and spectroscopy have been widely used in nano-photonics and material research due to their fine spatial resolution and broad spectral range. A number of simplified analytical models have been proposed to quantitatively understand the tip-scattered near-field signal. However, a rigorous interpretation of the experimental results is still lacking at this stage. Numerical modelings, on the other hand, are mostly done by simulating the local electric field slightly above the sample surface, which only qualitatively represents the near-field signal rendered by the tip-sample interaction. In this work, we performed a more comprehensive numerical simulation which is based on realistic experimental parameters and signal extraction procedures. By directly comparing to the experiments as well as other simulation efforts, our methods offer a more accurate quantitative description of the near-field signal, paving the way for future studies of complex systems at the nanoscale.

  15. Fast rigorous numerical method for the solution of the anisotropic neutron transport problem and the NITRAN system for fusion neutronics application. Pt. 1

    International Nuclear Information System (INIS)

    Takahashi, A.; Rusch, D.

    1979-07-01

    Some recent neutronics experiments for fusion reactor blankets show that the precise treatment of anisotropic secondary emissions for all types of neutron scattering is needed for neutron transport calculations. In the present work new rigorous methods, i.e. based on non-approximative microscopic neutron balance equations, are applied to treat the anisotropic collision source term in transport equations. The collision source calculation is free from approximations except for the discretization of energy, angle and space variables and includes the rigorous treatment of nonelastic collisions, as far as nuclear data are given. Two methods are presented: first the Ii-method, which relies on existing nuclear data files and then, as an ultimate goal, the I*-method, which aims at the use of future double-differential cross section data, but which is also applicable to the present single-differential data basis to allow a smooth transition to the new data type. An application of the Ii-method is given in the code system NITRAN which employs the Ssub(N)-method to solve the transport equations. Both rigorous methods, the Ii- and the I*-method, are applicable to all radiation transport problems and they can be used also in the Monte-Carlo-method to solve the transport problem. (orig./RW) [de

  16. [Progress in stable isotope labeled quantitative proteomics methods].

    Science.gov (United States)

    Zhou, Yuan; Shan, Yichu; Zhang, Lihua; Zhang, Yukui

    2013-06-01

    Quantitative proteomics is an important research field in post-genomics era. There are two strategies for proteome quantification: label-free methods and stable isotope labeling methods which have become the most important strategy for quantitative proteomics at present. In the past few years, a number of quantitative methods have been developed, which support the fast development in biology research. In this work, we discuss the progress in the stable isotope labeling methods for quantitative proteomics including relative and absolute quantitative proteomics, and then give our opinions on the outlook of proteome quantification methods.

  17. Deterministic quantitative risk assessment development

    Energy Technology Data Exchange (ETDEWEB)

    Dawson, Jane; Colquhoun, Iain [PII Pipeline Solutions Business of GE Oil and Gas, Cramlington Northumberland (United Kingdom)

    2009-07-01

    Current risk assessment practice in pipeline integrity management is to use a semi-quantitative index-based or model based methodology. This approach has been found to be very flexible and provide useful results for identifying high risk areas and for prioritizing physical integrity assessments. However, as pipeline operators progressively adopt an operating strategy of continual risk reduction with a view to minimizing total expenditures within safety, environmental, and reliability constraints, the need for quantitative assessments of risk levels is becoming evident. Whereas reliability based quantitative risk assessments can be and are routinely carried out on a site-specific basis, they require significant amounts of quantitative data for the results to be meaningful. This need for detailed and reliable data tends to make these methods unwieldy for system-wide risk k assessment applications. This paper describes methods for estimating risk quantitatively through the calibration of semi-quantitative estimates to failure rates for peer pipeline systems. The methods involve the analysis of the failure rate distribution, and techniques for mapping the rate to the distribution of likelihoods available from currently available semi-quantitative programs. By applying point value probabilities to the failure rates, deterministic quantitative risk assessment (QRA) provides greater rigor and objectivity than can usually be achieved through the implementation of semi-quantitative risk assessment results. The method permits a fully quantitative approach or a mixture of QRA and semi-QRA to suit the operator's data availability and quality, and analysis needs. For example, consequence analysis can be quantitative or can address qualitative ranges for consequence categories. Likewise, failure likelihoods can be output as classical probabilities or as expected failure frequencies as required. (author)

  18. Qualitative versus quantitative methods in psychiatric research.

    Science.gov (United States)

    Razafsha, Mahdi; Behforuzi, Hura; Azari, Hassan; Zhang, Zhiqun; Wang, Kevin K; Kobeissy, Firas H; Gold, Mark S

    2012-01-01

    Qualitative studies are gaining their credibility after a period of being misinterpreted as "not being quantitative." Qualitative method is a broad umbrella term for research methodologies that describe and explain individuals' experiences, behaviors, interactions, and social contexts. In-depth interview, focus groups, and participant observation are among the qualitative methods of inquiry commonly used in psychiatry. Researchers measure the frequency of occurring events using quantitative methods; however, qualitative methods provide a broader understanding and a more thorough reasoning behind the event. Hence, it is considered to be of special importance in psychiatry. Besides hypothesis generation in earlier phases of the research, qualitative methods can be employed in questionnaire design, diagnostic criteria establishment, feasibility studies, as well as studies of attitude and beliefs. Animal models are another area that qualitative methods can be employed, especially when naturalistic observation of animal behavior is important. However, since qualitative results can be researcher's own view, they need to be statistically confirmed, quantitative methods. The tendency to combine both qualitative and quantitative methods as complementary methods has emerged over recent years. By applying both methods of research, scientists can take advantage of interpretative characteristics of qualitative methods as well as experimental dimensions of quantitative methods.

  19. Estimation of the breaking of rigor mortis by myotonometry.

    Science.gov (United States)

    Vain, A; Kauppila, R; Vuori, E

    1996-05-31

    Myotonometry was used to detect breaking of rigor mortis. The myotonometer is a new instrument which measures the decaying oscillations of a muscle after a brief mechanical impact. The method gives two numerical parameters for rigor mortis, namely the period and decrement of the oscillations, both of which depend on the time period elapsed after death. In the case of breaking the rigor mortis by muscle lengthening, both the oscillation period and decrement decreased, whereas, shortening the muscle caused the opposite changes. Fourteen h after breaking the stiffness characteristics of the right and left m. biceps brachii, or oscillation periods, were assimilated. However, the values for decrement of the muscle, reflecting the dissipation of mechanical energy, maintained their differences.

  20. The Rigor Mortis of Education: Rigor Is Required in a Dying Educational System

    Science.gov (United States)

    Mixon, Jason; Stuart, Jerry

    2009-01-01

    In an effort to answer the "Educational Call to Arms", our national public schools have turned to Advanced Placement (AP) courses as the predominate vehicle used to address the lack of academic rigor in our public high schools. Advanced Placement is believed by many to provide students with the rigor and work ethic necessary to…

  1. Realizing rigor in the mathematics classroom

    CERN Document Server

    Hull, Ted H (Henry); Balka, Don S

    2014-01-01

    Rigor put within reach! Rigor: The Common Core has made it policy-and this first-of-its-kind guide takes math teachers and leaders through the process of making it reality. Using the Proficiency Matrix as a framework, the authors offer proven strategies and practical tools for successful implementation of the CCSS mathematical practices-with rigor as a central objective. You'll learn how to Define rigor in the context of each mathematical practice Identify and overcome potential issues, including differentiating instruction and using data

  2. Rigor, vigor, and the study of health disparities.

    Science.gov (United States)

    Adler, Nancy; Bush, Nicole R; Pantell, Matthew S

    2012-10-16

    Health disparities research spans multiple fields and methods and documents strong links between social disadvantage and poor health. Associations between socioeconomic status (SES) and health are often taken as evidence for the causal impact of SES on health, but alternative explanations, including the impact of health on SES, are plausible. Studies showing the influence of parents' SES on their children's health provide evidence for a causal pathway from SES to health, but have limitations. Health disparities researchers face tradeoffs between "rigor" and "vigor" in designing studies that demonstrate how social disadvantage becomes biologically embedded and results in poorer health. Rigorous designs aim to maximize precision in the measurement of SES and health outcomes through methods that provide the greatest control over temporal ordering and causal direction. To achieve precision, many studies use a single SES predictor and single disease. However, doing so oversimplifies the multifaceted, entwined nature of social disadvantage and may overestimate the impact of that one variable and underestimate the true impact of social disadvantage on health. In addition, SES effects on overall health and functioning are likely to be greater than effects on any one disease. Vigorous designs aim to capture this complexity and maximize ecological validity through more complete assessment of social disadvantage and health status, but may provide less-compelling evidence of causality. Newer approaches to both measurement and analysis may enable enhanced vigor as well as rigor. Incorporating both rigor and vigor into studies will provide a fuller understanding of the causes of health disparities.

  3. The Specificity of Observational Studies in Physical Activity and Sports Sciences: Moving Forward in Mixed Methods Research and Proposals for Achieving Quantitative and Qualitative Symmetry.

    Science.gov (United States)

    Anguera, M Teresa; Camerino, Oleguer; Castañer, Marta; Sánchez-Algarra, Pedro; Onwuegbuzie, Anthony J

    2017-01-01

    Mixed methods studies are been increasingly applied to a diversity of fields. In this paper, we discuss the growing use-and enormous potential-of mixed methods research in the field of sport and physical activity. A second aim is to contribute to strengthening the characteristics of mixed methods research by showing how systematic observation offers rigor within a flexible framework that can be applied to a wide range of situations. Observational methodology is characterized by high scientific rigor and flexibility throughout its different stages and allows the objective study of spontaneous behavior in natural settings, with no external influence. Mixed methods researchers need to take bold yet thoughtful decisions regarding both substantive and procedural issues. We present three fundamental and complementary ideas to guide researchers in this respect: we show why studies of sport and physical activity that use a mixed methods research approach should be included in the field of mixed methods research, we highlight the numerous possibilities offered by observational methodology in this field through the transformation of descriptive data into quantifiable code matrices, and we discuss possible solutions for achieving true integration of qualitative and quantitative findings.

  4. The Specificity of Observational Studies in Physical Activity and Sports Sciences: Moving Forward in Mixed Methods Research and Proposals for Achieving Quantitative and Qualitative Symmetry

    Directory of Open Access Journals (Sweden)

    M. Teresa Anguera

    2017-12-01

    Full Text Available Mixed methods studies are been increasingly applied to a diversity of fields. In this paper, we discuss the growing use—and enormous potential—of mixed methods research in the field of sport and physical activity. A second aim is to contribute to strengthening the characteristics of mixed methods research by showing how systematic observation offers rigor within a flexible framework that can be applied to a wide range of situations. Observational methodology is characterized by high scientific rigor and flexibility throughout its different stages and allows the objective study of spontaneous behavior in natural settings, with no external influence. Mixed methods researchers need to take bold yet thoughtful decisions regarding both substantive and procedural issues. We present three fundamental and complementary ideas to guide researchers in this respect: we show why studies of sport and physical activity that use a mixed methods research approach should be included in the field of mixed methods research, we highlight the numerous possibilities offered by observational methodology in this field through the transformation of descriptive data into quantifiable code matrices, and we discuss possible solutions for achieving true integration of qualitative and quantitative findings.

  5. Why so many "rigorous" evaluations fail to identify unintended consequences of development programs: How mixed methods can contribute.

    Science.gov (United States)

    Bamberger, Michael; Tarsilla, Michele; Hesse-Biber, Sharlene

    2016-04-01

    Many widely-used impact evaluation designs, including randomized control trials (RCTs) and quasi-experimental designs (QEDs), frequently fail to detect what are often quite serious unintended consequences of development programs. This seems surprising as experienced planners and evaluators are well aware that unintended consequences frequently occur. Most evaluation designs are intended to determine whether there is credible evidence (statistical, theory-based or narrative) that programs have achieved their intended objectives and the logic of many evaluation designs, even those that are considered the most "rigorous," does not permit the identification of outcomes that were not specified in the program design. We take the example of RCTs as they are considered by many to be the most rigorous evaluation designs. We present a numbers of cases to illustrate how infusing RCTs with a mixed-methods approach (sometimes called an "RCT+" design) can strengthen the credibility of these designs and can also capture important unintended consequences. We provide a Mixed Methods Evaluation Framework that identifies 9 ways in which UCs can occur, and we apply this framework to two of the case studies. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Biclustering via optimal re-ordering of data matrices in systems biology: rigorous methods and comparative studies

    Directory of Open Access Journals (Sweden)

    Feng Xiao-Jiang

    2008-10-01

    Full Text Available Abstract Background The analysis of large-scale data sets via clustering techniques is utilized in a number of applications. Biclustering in particular has emerged as an important problem in the analysis of gene expression data since genes may only jointly respond over a subset of conditions. Biclustering algorithms also have important applications in sample classification where, for instance, tissue samples can be classified as cancerous or normal. Many of the methods for biclustering, and clustering algorithms in general, utilize simplified models or heuristic strategies for identifying the "best" grouping of elements according to some metric and cluster definition and thus result in suboptimal clusters. Results In this article, we present a rigorous approach to biclustering, OREO, which is based on the Optimal RE-Ordering of the rows and columns of a data matrix so as to globally minimize the dissimilarity metric. The physical permutations of the rows and columns of the data matrix can be modeled as either a network flow problem or a traveling salesman problem. Cluster boundaries in one dimension are used to partition and re-order the other dimensions of the corresponding submatrices to generate biclusters. The performance of OREO is tested on (a metabolite concentration data, (b an image reconstruction matrix, (c synthetic data with implanted biclusters, and gene expression data for (d colon cancer data, (e breast cancer data, as well as (f yeast segregant data to validate the ability of the proposed method and compare it to existing biclustering and clustering methods. Conclusion We demonstrate that this rigorous global optimization method for biclustering produces clusters with more insightful groupings of similar entities, such as genes or metabolites sharing common functions, than other clustering and biclustering algorithms and can reconstruct underlying fundamental patterns in the data for several distinct sets of data matrices arising

  7. Revisiting the scientific method to improve rigor and reproducibility of immunohistochemistry in reproductive science.

    Science.gov (United States)

    Manuel, Sharrón L; Johnson, Brian W; Frevert, Charles W; Duncan, Francesca E

    2018-04-21

    Immunohistochemistry (IHC) is a robust scientific tool whereby cellular components are visualized within a tissue, and this method has been and continues to be a mainstay for many reproductive biologists. IHC is highly informative if performed and interpreted correctly, but studies have shown that the general use and reporting of appropriate controls in IHC experiments is low. This omission of the scientific method can result in data that lacks rigor and reproducibility. In this editorial, we highlight key concepts in IHC controls and describe an opportunity for our field to partner with the Histochemical Society to adopt their IHC guidelines broadly as researchers, authors, ad hoc reviewers, editorial board members, and editors-in-chief. Such cross-professional society interactions will ensure that we produce the highest quality data as new technologies emerge that still rely upon the foundations of classic histological and immunohistochemical principles.

  8. Methods for Quantitative Creatinine Determination.

    Science.gov (United States)

    Moore, John F; Sharer, J Daniel

    2017-04-06

    Reliable measurement of creatinine is necessary to assess kidney function, and also to quantitate drug levels and diagnostic compounds in urine samples. The most commonly used methods are based on the Jaffe principal of alkaline creatinine-picric acid complex color formation. However, other compounds commonly found in serum and urine may interfere with Jaffe creatinine measurements. Therefore, many laboratories have made modifications to the basic method to remove or account for these interfering substances. This appendix will summarize the basic Jaffe method, as well as a modified, automated version. Also described is a high performance liquid chromatography (HPLC) method that separates creatinine from contaminants prior to direct quantification by UV absorption. Lastly, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method is described that uses stable isotope dilution to reliably quantify creatinine in any sample. This last approach has been recommended by experts in the field as a means to standardize all quantitative creatinine methods against an accepted reference. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  9. Causality as a Rigorous Notion and Quantitative Causality Analysis with Time Series

    Science.gov (United States)

    Liang, X. S.

    2017-12-01

    Given two time series, can one faithfully tell, in a rigorous and quantitative way, the cause and effect between them? Here we show that this important and challenging question (one of the major challenges in the science of big data), which is of interest in a wide variety of disciplines, has a positive answer. Particularly, for linear systems, the maximal likelihood estimator of the causality from a series X2 to another series X1, written T2→1, turns out to be concise in form: T2→1 = [C11 C12 C2,d1 — C112 C1,d1] / [C112 C22 — C11C122] where Cij (i,j=1,2) is the sample covariance between Xi and Xj, and Ci,dj the covariance between Xi and ΔXj/Δt, the difference approximation of dXj/dt using the Euler forward scheme. An immediate corollary is that causation implies correlation, but not vice versa, resolving the long-standing debate over causation versus correlation. The above formula has been validated with touchstone series purportedly generated with one-way causality that evades the classical approaches such as Granger causality test and transfer entropy analysis. It has also been applied successfully to the investigation of many real problems. Through a simple analysis with the stock series of IBM and GE, an unusually strong one-way causality is identified from the former to the latter in their early era, revealing to us an old story, which has almost faded into oblivion, about "Seven Dwarfs" competing with a "Giant" for the computer market. Another example presented here regards the cause-effect relation between the two climate modes, El Niño and Indian Ocean Dipole (IOD). In general, these modes are mutually causal, but the causality is asymmetric. To El Niño, the information flowing from IOD manifests itself as a propagation of uncertainty from the Indian Ocean. In the third example, an unambiguous one-way causality is found between CO2 and the global mean temperature anomaly. While it is confirmed that CO2 indeed drives the recent global warming

  10. Systemic Errors in Quantitative Polymerase Chain Reaction Titration of Self-Complementary Adeno-Associated Viral Vectors and Improved Alternative Methods

    Science.gov (United States)

    Fagone, Paolo; Wright, J. Fraser; Nathwani, Amit C.; Nienhuis, Arthur W.; Davidoff, Andrew M.

    2012-01-01

    Abstract Self-complementary AAV (scAAV) vector genomes contain a covalently closed hairpin derived from a mutated inverted terminal repeat that connects the two monomer single-stranded genomes into a head-to-head or tail-to-tail dimer. We found that during quantitative PCR (qPCR) this structure inhibits the amplification of proximal amplicons and causes the systemic underreporting of copy number by as much as 10-fold. We show that cleavage of scAAV vector genomes with restriction endonuclease to liberate amplicons from the covalently closed terminal hairpin restores quantitative amplification, and we implement this procedure in a simple, modified qPCR titration method for scAAV vectors. In addition, we developed and present an AAV genome titration procedure based on gel electrophoresis that requires minimal sample processing and has low interassay variability, and as such is well suited for the rigorous quality control demands of clinical vector production facilities. PMID:22428975

  11. Quantitative methods in psychology: inevitable and useless

    Directory of Open Access Journals (Sweden)

    Aaro Toomela

    2010-07-01

    Full Text Available Science begins with the question, what do I want to know? Science becomes science, however, only when this question is justified and the appropriate methodology is chosen for answering the research question. Research question should precede the other questions; methods should be chosen according to the research question and not vice versa. Modern quantitative psychology has accepted method as primary; research questions are adjusted to the methods. For understanding thinking in modern quantitative psychology, two epistemologies should be distinguished: structural-systemic that is based on Aristotelian thinking, and associative-quantitative that is based on Cartesian-Humean thinking. The first aims at understanding the structure that underlies the studied processes; the second looks for identification of cause-effect relationships between the events with no possible access to the understanding of the structures that underlie the processes. Quantitative methodology in particular as well as mathematical psychology in general, is useless for answering questions about structures and processes that underlie observed behaviors. Nevertheless, quantitative science is almost inevitable in a situation where the systemic-structural basis of behavior is not well understood; all sorts of applied decisions can be made on the basis of quantitative studies. In order to proceed, psychology should study structures; methodologically, constructive experiments should be added to observations and analytic experiments.

  12. Rigorous Science: a How-To Guide

    Directory of Open Access Journals (Sweden)

    Arturo Casadevall

    2016-11-01

    Full Text Available Proposals to improve the reproducibility of biomedical research have emphasized scientific rigor. Although the word “rigor” is widely used, there has been little specific discussion as to what it means and how it can be achieved. We suggest that scientific rigor combines elements of mathematics, logic, philosophy, and ethics. We propose a framework for rigor that includes redundant experimental design, sound statistical analysis, recognition of error, avoidance of logical fallacies, and intellectual honesty. These elements lead to five actionable recommendations for research education.

  13. Disciplining Bioethics: Towards a Standard of Methodological Rigor in Bioethics Research

    Science.gov (United States)

    Adler, Daniel; Shaul, Randi Zlotnik

    2012-01-01

    Contemporary bioethics research is often described as multi- or interdisciplinary. Disciplines are characterized, in part, by their methods. Thus, when bioethics research draws on a variety of methods, it crosses disciplinary boundaries. Yet each discipline has its own standard of rigor—so when multiple disciplinary perspectives are considered, what constitutes rigor? This question has received inadequate attention, as there is considerable disagreement regarding the disciplinary status of bioethics. This disagreement has presented five challenges to bioethics research. Addressing them requires consideration of the main types of cross-disciplinary research, and consideration of proposals aiming to ensure rigor in bioethics research. PMID:22686634

  14. The rise of quantitative methods in Psychology

    Directory of Open Access Journals (Sweden)

    Denis Cousineau

    2005-09-01

    Full Text Available Quantitative methods have a long history in some scientific fields. Indeed, no one today would consider a qualitative data set in physics or a qualitative theory in chemistry. Quantitative methods are so central in these fields that they are often labelled “hard sciences”. Here, we examine the question whether psychology is ready to enter the “hard science club” like biology did in the forties. The facts that a over half of the statistical techniques used in psychology are less than 40 years old and that b the number of simulations in empirical papers has followed an exponential growth since the eighties, both suggests that the answer is yes. The purpose of Tutorials in Quantitative Methods for Psychology is to provide a concise and easy access to the currents methods.

  15. A plea for rigorous conceptual analysis as central method in transnational law design

    NARCIS (Netherlands)

    Rijgersberg, R.; van der Kaaij, H.

    2013-01-01

    Although shared problems are generally easily identified in transnational law design, it is considerably more difficult to design frameworks that transcend the peculiarities of local law in a univocal fashion. The following exposition is a plea for giving more prominence to rigorous conceptual

  16. From themes to hypotheses: following up with quantitative methods.

    Science.gov (United States)

    Morgan, David L

    2015-06-01

    One important category of mixed-methods research designs consists of quantitative studies that follow up on qualitative research. In this case, the themes that serve as the results from the qualitative methods generate hypotheses for testing through the quantitative methods. That process requires operationalization to translate the concepts from the qualitative themes into quantitative variables. This article illustrates these procedures with examples that range from simple operationalization to the evaluation of complex models. It concludes with an argument for not only following up qualitative work with quantitative studies but also the reverse, and doing so by going beyond integrating methods within single projects to include broader mutual attention from qualitative and quantitative researchers who work in the same field. © The Author(s) 2015.

  17. Increased scientific rigor will improve reliability of research and effectiveness of management

    Science.gov (United States)

    Sells, Sarah N.; Bassing, Sarah B.; Barker, Kristin J.; Forshee, Shannon C.; Keever, Allison; Goerz, James W.; Mitchell, Michael S.

    2018-01-01

    Rigorous science that produces reliable knowledge is critical to wildlife management because it increases accurate understanding of the natural world and informs management decisions effectively. Application of a rigorous scientific method based on hypothesis testing minimizes unreliable knowledge produced by research. To evaluate the prevalence of scientific rigor in wildlife research, we examined 24 issues of the Journal of Wildlife Management from August 2013 through July 2016. We found 43.9% of studies did not state or imply a priori hypotheses, which are necessary to produce reliable knowledge. We posit that this is due, at least in part, to a lack of common understanding of what rigorous science entails, how it produces more reliable knowledge than other forms of interpreting observations, and how research should be designed to maximize inferential strength and usefulness of application. Current primary literature does not provide succinct explanations of the logic behind a rigorous scientific method or readily applicable guidance for employing it, particularly in wildlife biology; we therefore synthesized an overview of the history, philosophy, and logic that define scientific rigor for biological studies. A rigorous scientific method includes 1) generating a research question from theory and prior observations, 2) developing hypotheses (i.e., plausible biological answers to the question), 3) formulating predictions (i.e., facts that must be true if the hypothesis is true), 4) designing and implementing research to collect data potentially consistent with predictions, 5) evaluating whether predictions are consistent with collected data, and 6) drawing inferences based on the evaluation. Explicitly testing a priori hypotheses reduces overall uncertainty by reducing the number of plausible biological explanations to only those that are logically well supported. Such research also draws inferences that are robust to idiosyncratic observations and

  18. QTest: Quantitative Testing of Theories of Binary Choice.

    Science.gov (United States)

    Regenwetter, Michel; Davis-Stober, Clintin P; Lim, Shiau Hong; Guo, Ying; Popova, Anna; Zwilling, Chris; Cha, Yun-Shil; Messner, William

    2014-01-01

    The goal of this paper is to make modeling and quantitative testing accessible to behavioral decision researchers interested in substantive questions. We provide a novel, rigorous, yet very general, quantitative diagnostic framework for testing theories of binary choice. This permits the nontechnical scholar to proceed far beyond traditionally rather superficial methods of analysis, and it permits the quantitatively savvy scholar to triage theoretical proposals before investing effort into complex and specialized quantitative analyses. Our theoretical framework links static algebraic decision theory with observed variability in behavioral binary choice data. The paper is supplemented with a custom-designed public-domain statistical analysis package, the QTest software. We illustrate our approach with a quantitative analysis using published laboratory data, including tests of novel versions of "Random Cumulative Prospect Theory." A major asset of the approach is the potential to distinguish decision makers who have a fixed preference and commit errors in observed choices from decision makers who waver in their preferences.

  19. QTest: Quantitative Testing of Theories of Binary Choice

    Science.gov (United States)

    Regenwetter, Michel; Davis-Stober, Clintin P.; Lim, Shiau Hong; Guo, Ying; Popova, Anna; Zwilling, Chris; Cha, Yun-Shil; Messner, William

    2014-01-01

    The goal of this paper is to make modeling and quantitative testing accessible to behavioral decision researchers interested in substantive questions. We provide a novel, rigorous, yet very general, quantitative diagnostic framework for testing theories of binary choice. This permits the nontechnical scholar to proceed far beyond traditionally rather superficial methods of analysis, and it permits the quantitatively savvy scholar to triage theoretical proposals before investing effort into complex and specialized quantitative analyses. Our theoretical framework links static algebraic decision theory with observed variability in behavioral binary choice data. The paper is supplemented with a custom-designed public-domain statistical analysis package, the QTest software. We illustrate our approach with a quantitative analysis using published laboratory data, including tests of novel versions of “Random Cumulative Prospect Theory.” A major asset of the approach is the potential to distinguish decision makers who have a fixed preference and commit errors in observed choices from decision makers who waver in their preferences. PMID:24999495

  20. Quantitative imaging methods in osteoporosis.

    Science.gov (United States)

    Oei, Ling; Koromani, Fjorda; Rivadeneira, Fernando; Zillikens, M Carola; Oei, Edwin H G

    2016-12-01

    Osteoporosis is characterized by a decreased bone mass and quality resulting in an increased fracture risk. Quantitative imaging methods are critical in the diagnosis and follow-up of treatment effects in osteoporosis. Prior radiographic vertebral fractures and bone mineral density (BMD) as a quantitative parameter derived from dual-energy X-ray absorptiometry (DXA) are among the strongest known predictors of future osteoporotic fractures. Therefore, current clinical decision making relies heavily on accurate assessment of these imaging features. Further, novel quantitative techniques are being developed to appraise additional characteristics of osteoporosis including three-dimensional bone architecture with quantitative computed tomography (QCT). Dedicated high-resolution (HR) CT equipment is available to enhance image quality. At the other end of the spectrum, by utilizing post-processing techniques such as the trabecular bone score (TBS) information on three-dimensional architecture can be derived from DXA images. Further developments in magnetic resonance imaging (MRI) seem promising to not only capture bone micro-architecture but also characterize processes at the molecular level. This review provides an overview of various quantitative imaging techniques based on different radiological modalities utilized in clinical osteoporosis care and research.

  1. Experimental evaluation of rigor mortis. VII. Effect of ante- and post-mortem electrocution on the evolution of rigor mortis.

    Science.gov (United States)

    Krompecher, T; Bergerioux, C

    1988-01-01

    The influence of electrocution on the evolution of rigor mortis was studied on rats. Our experiments showed that: (1) Electrocution hastens the onset of rigor mortis. After an electrocution of 90 s, a complete rigor develops already 1 h post-mortem (p.m.) compared to 5 h p.m. for the controls. (2) Electrocution hastens the passing of rigor mortis. After an electrocution of 90 s, the first significant decrease occurs at 3 h p.m. (8 h p.m. in the controls). (3) These modifications in rigor mortis evolution are less pronounced in the limbs not directly touched by the electric current. (4) In case of post-mortem electrocution, the changes are slightly less pronounced, the resistance is higher and the absorbed energy is lower as compared with the ante-mortem electrocution cases. The results are completed by two practical observations on human electrocution cases.

  2. Quantitative autoradiography - a method of radioactivity measurement

    International Nuclear Information System (INIS)

    Treutler, H.C.; Freyer, K.

    1988-01-01

    In the last years the autoradiography has been developed to a quantitative method of radioactivity measurement. Operating techniques of quantitative autoradiography are demonstrated using special standard objects. Influences of irradiation quality, of backscattering in sample and detector materials, and of sensitivity and fading of the detectors are considered. Furthermore, questions of quantitative evaluation of autoradiograms are dealt with, and measuring errors are discussed. Finally, some practical uses of quantitative autoradiography are demonstrated by means of the estimation of activity distribution in radioactive foil samples. (author)

  3. Useful, Used, and Peer Approved: The Importance of Rigor and Accessibility in Postsecondary Research and Evaluation. WISCAPE Viewpoints

    Science.gov (United States)

    Vaade, Elizabeth; McCready, Bo

    2012-01-01

    Traditionally, researchers, policymakers, and practitioners have perceived a tension between rigor and accessibility in quantitative research and evaluation in postsecondary education. However, this study indicates that both producers and consumers of these studies value high-quality work and clear findings that can reach multiple audiences. The…

  4. Qualitative and quantitative methods in health research

    OpenAIRE

    V?zquez Navarrete, M. Luisa

    2009-01-01

    Introduction Research in the area of health has been traditionally dominated by quantitative research. However, the complexity of ill-health, which is socially constructed by individuals, health personnel and health authorities have motivated the search for other forms to approach knowledge. Aim To discuss the complementarities of qualitative and quantitative research methods in the generation of knowledge. Contents The purpose of quantitative research is to measure the magnitude of an event,...

  5. Scattering of atoms by a stationary sinusoidal hard wall: Rigorous treatment in (n+1) dimensions and comparison with the Rayleigh method

    International Nuclear Information System (INIS)

    Goodman, F.O.

    1977-01-01

    A rigorous treatment of the scattering of atoms by a stationary sinusoidal hard wall in (n+1) dimensions is presented, a previous treatment by Masel, Merrill, and Miller for n=1 being contained as a special case. Numerical comparisons are made with the GR method of Garcia, which incorporates the Rayleigh hypothesis. Advantages and disadvantages of both methods are discussed, and it is concluded that the Rayleigh GR method, if handled properly, will probably work satisfactorily in physically realistic cases

  6. Development of rigor mortis is not affected by muscle volume.

    Science.gov (United States)

    Kobayashi, M; Ikegaya, H; Takase, I; Hatanaka, K; Sakurada, K; Iwase, H

    2001-04-01

    There is a hypothesis suggesting that rigor mortis progresses more rapidly in small muscles than in large muscles. We measured rigor mortis as tension determined isometrically in rat musculus erector spinae that had been cut into muscle bundles of various volumes. The muscle volume did not influence either the progress or the resolution of rigor mortis, which contradicts the hypothesis. Differences in pre-rigor load on the muscles influenced the onset and resolution of rigor mortis in a few pairs of samples, but did not influence the time taken for rigor mortis to reach its full extent after death. Moreover, the progress of rigor mortis in this muscle was biphasic; this may reflect the early rigor of red muscle fibres and the late rigor of white muscle fibres.

  7. Quantitative Methods for Teaching Review

    OpenAIRE

    Irina Milnikova; Tamara Shioshvili

    2011-01-01

    A new method of quantitative evaluation of teaching processes is elaborated. On the base of scores data, the method permits to evaluate efficiency of teaching within one group of students and comparative teaching efficiency in two or more groups. As basic characteristics of teaching efficiency heterogeneity, stability and total variability indices both for only one group and for comparing different groups are used. The method is easy to use and permits to rank results of teaching review which...

  8. A rigorous pole representation of multilevel cross sections and its practical applications

    International Nuclear Information System (INIS)

    Hwang, R.N.

    1987-01-01

    In this article a rigorous method for representing the multilevel cross sections and its practical applications are described. It is a generalization of the rationale suggested by de Saussure and Perez for the s-wave resonances. A computer code WHOPPER has been developed to convert the Reich-Moore parameters into the pole and residue parameters in momentum space. Sample calculations have been carried out to illustrate that the proposed method preserves the rigor of the Reich-Moore cross sections exactly. An analytical method has been developed to evaluate the pertinent Doppler-broadened line shape functions. A discussion is presented on how to minimize the number of pole parameters so that the existing reactor codes can be best utilized

  9. Long persistence of rigor mortis at constant low temperature.

    Science.gov (United States)

    Varetto, Lorenzo; Curto, Ombretta

    2005-01-06

    We studied the persistence of rigor mortis by using physical manipulation. We tested the mobility of the knee on 146 corpses kept under refrigeration at Torino's city mortuary at a constant temperature of +4 degrees C. We found a persistence of complete rigor lasting for 10 days in all the cadavers we kept under observation; and in one case, rigor lasted for 16 days. Between the 11th and the 17th days, a progressively increasing number of corpses showed a change from complete into partial rigor (characterized by partial bending of the articulation). After the 17th day, all the remaining corpses showed partial rigor and in the two cadavers that were kept under observation "à outrance" we found the absolute resolution of rigor mortis occurred on the 28th day. Our results prove that it is possible to find a persistence of rigor mortis that is much longer than the expected when environmental conditions resemble average outdoor winter temperatures in temperate zones. Therefore, this datum must be considered when a corpse is found in those environmental conditions so that when estimating the time of death, we are not misled by the long persistence of rigor mortis.

  10. Sonoelasticity to monitor mechanical changes during rigor and ageing.

    Science.gov (United States)

    Ayadi, A; Culioli, J; Abouelkaram, S

    2007-06-01

    We propose the use of sonoelasticity as a non-destructive method to monitor changes in the resistance of muscle fibres, unaffected by connective tissue. Vibrations were applied at low frequency to induce oscillations in soft tissues and an ultrasound transducer was used to detect the motions. The experiments were carried out on the M. biceps femoris muscles of three beef cattle. In addition to the sonoelasticity measurements, the changes in meat during rigor and ageing were followed by measurements of both the mechanical resistance of myofibres and pH. The variations of mechanical resistance and pH were compared to those of the sonoelastic variables (velocity and attenuation) at two frequencies. The relationships between pH and velocity or attenuation and between the velocity or attenuation and the stress at 20% deformation were highly correlated. We concluded that sonoelasticity is a non-destructive method that can be used to monitor mechanical changes in muscle fibers during rigor-mortis and ageing.

  11. Designing A Mixed Methods Study In Primary Care

    Science.gov (United States)

    Creswell, John W.; Fetters, Michael D.; Ivankova, Nataliya V.

    2004-01-01

    BACKGROUND Mixed methods or multimethod research holds potential for rigorous, methodologically sound investigations in primary care. The objective of this study was to use criteria from the literature to evaluate 5 mixed methods studies in primary care and to advance 3 models useful for designing such investigations. METHODS We first identified criteria from the social and behavioral sciences to analyze mixed methods studies in primary care research. We then used the criteria to evaluate 5 mixed methods investigations published in primary care research journals. RESULTS Of the 5 studies analyzed, 3 included a rationale for mixing based on the need to develop a quantitative instrument from qualitative data or to converge information to best understand the research topic. Quantitative data collection involved structured interviews, observational checklists, and chart audits that were analyzed using descriptive and inferential statistical procedures. Qualitative data consisted of semistructured interviews and field observations that were analyzed using coding to develop themes and categories. The studies showed diverse forms of priority: equal priority, qualitative priority, and quantitative priority. Data collection involved quantitative and qualitative data gathered both concurrently and sequentially. The integration of the quantitative and qualitative data in these studies occurred between data analysis from one phase and data collection from a subsequent phase, while analyzing the data, and when reporting the results. DISCUSSION We recommend instrument-building, triangulation, and data transformation models for mixed methods designs as useful frameworks to add rigor to investigations in primary care. We also discuss the limitations of our study and the need for future research. PMID:15053277

  12. Mapcurves: a quantitative method for comparing categorical maps.

    Science.gov (United States)

    William W. Hargrove; M. Hoffman Forrest; Paul F. Hessburg

    2006-01-01

    We present Mapcurves, a quantitative goodness-of-fit (GOF) method that unambiguously shows the degree of spatial concordance between two or more categorical maps. Mapcurves graphically and quantitatively evaluate the degree of fit among any number of maps and quantify a GOF for each polygon, as well as the entire map. The Mapcurve method indicates a perfect fit even if...

  13. Uncertainty of quantitative microbiological methods of pharmaceutical analysis.

    Science.gov (United States)

    Gunar, O V; Sakhno, N G

    2015-12-30

    The total uncertainty of quantitative microbiological methods, used in pharmaceutical analysis, consists of several components. The analysis of the most important sources of the quantitative microbiological methods variability demonstrated no effect of culture media and plate-count techniques in the estimation of microbial count while the highly significant effect of other factors (type of microorganism, pharmaceutical product and individual reading and interpreting errors) was established. The most appropriate method of statistical analysis of such data was ANOVA which enabled not only the effect of individual factors to be estimated but also their interactions. Considering all the elements of uncertainty and combining them mathematically the combined relative uncertainty of the test results was estimated both for method of quantitative examination of non-sterile pharmaceuticals and microbial count technique without any product. These data did not exceed 35%, appropriated for a traditional plate count methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Rigorous derivation from Landau-de Gennes theory to Ericksen-Leslie theory

    OpenAIRE

    Wang, Wei; Zhang, Pingwen; Zhang, Zhifei

    2013-01-01

    Starting from Beris-Edwards system for the liquid crystal, we present a rigorous derivation of Ericksen-Leslie system with general Ericksen stress and Leslie stress by using the Hilbert expansion method.

  15. A case of instantaneous rigor?

    Science.gov (United States)

    Pirch, J; Schulz, Y; Klintschar, M

    2013-09-01

    The question of whether instantaneous rigor mortis (IR), the hypothetic sudden occurrence of stiffening of the muscles upon death, actually exists has been controversially debated over the last 150 years. While modern German forensic literature rejects this concept, the contemporary British literature is more willing to embrace it. We present the case of a young woman who suffered from diabetes and who was found dead in an upright standing position with back and shoulders leaned against a punchbag and a cupboard. Rigor mortis was fully established, livor mortis was strong and according to the position the body was found in. After autopsy and toxicological analysis, it was stated that death most probably occurred due to a ketoacidotic coma with markedly increased values of glucose and lactate in the cerebrospinal fluid as well as acetone in blood and urine. Whereas the position of the body is most unusual, a detailed analysis revealed that it is a stable position even without rigor mortis. Therefore, this case does not further support the controversial concept of IR.

  16. Quantitative method for determination of body inorganic iodine

    International Nuclear Information System (INIS)

    Filatov, A.A.; Tatsievskij, V.A.

    1991-01-01

    An original method of quantitation of body inorganic iodine, based upon a simultaneous administration of a known dose of stable and radioactive iodine with subsequent radiometry of the thyroid was proposed. The calculation is based upon the principle of the dilution of radiactive iodine in human inorganic iodine space. The method permits quantitation of the amount of inorganic iodine with regard to individual features of inorganic space. The method is characterized by simplicity and is not invasive for a patient

  17. Designing a mixed methods study in primary care.

    Science.gov (United States)

    Creswell, John W; Fetters, Michael D; Ivankova, Nataliya V

    2004-01-01

    Mixed methods or multimethod research holds potential for rigorous, methodologically sound investigations in primary care. The objective of this study was to use criteria from the literature to evaluate 5 mixed methods studies in primary care and to advance 3 models useful for designing such investigations. We first identified criteria from the social and behavioral sciences to analyze mixed methods studies in primary care research. We then used the criteria to evaluate 5 mixed methods investigations published in primary care research journals. Of the 5 studies analyzed, 3 included a rationale for mixing based on the need to develop a quantitative instrument from qualitative data or to converge information to best understand the research topic. Quantitative data collection involved structured interviews, observational checklists, and chart audits that were analyzed using descriptive and inferential statistical procedures. Qualitative data consisted of semistructured interviews and field observations that were analyzed using coding to develop themes and categories. The studies showed diverse forms of priority: equal priority, qualitative priority, and quantitative priority. Data collection involved quantitative and qualitative data gathered both concurrently and sequentially. The integration of the quantitative and qualitative data in these studies occurred between data analysis from one phase and data collection from a subsequent phase, while analyzing the data, and when reporting the results. We recommend instrument-building, triangulation, and data transformation models for mixed methods designs as useful frameworks to add rigor to investigations in primary care. We also discuss the limitations of our study and the need for future research.

  18. Instrumentation and quantitative methods of evaluation

    International Nuclear Information System (INIS)

    Beck, R.N.; Cooper, M.D.

    1991-01-01

    This report summarizes goals and accomplishments of the research program entitled Instrumentation and Quantitative Methods of Evaluation, during the period January 15, 1989 through July 15, 1991. This program is very closely integrated with the radiopharmaceutical program entitled Quantitative Studies in Radiopharmaceutical Science. Together, they constitute the PROGRAM OF NUCLEAR MEDICINE AND QUANTITATIVE IMAGING RESEARCH within The Franklin McLean Memorial Research Institute (FMI). The program addresses problems involving the basic science and technology that underlie the physical and conceptual tools of radiotracer methodology as they relate to the measurement of structural and functional parameters of physiologic importance in health and disease. The principal tool is quantitative radionuclide imaging. The objective of this program is to further the development and transfer of radiotracer methodology from basic theory to routine clinical practice. The focus of the research is on the development of new instruments and radiopharmaceuticals, and the evaluation of these through the phase of clinical feasibility. 234 refs., 11 figs., 2 tabs

  19. Quantitative Methods for Molecular Diagnostic and Therapeutic Imaging

    OpenAIRE

    Li, Quanzheng

    2013-01-01

    This theme issue provides an overview on the basic quantitative methods, an in-depth discussion on the cutting-edge quantitative analysis approaches as well as their applications for both static and dynamic molecular diagnostic and therapeutic imaging.

  20. Introduction to quantitative research methods an investigative approach

    CERN Document Server

    Balnaves, Mark

    2001-01-01

    Introduction to Quantitative Research Methods is a student-friendly introduction to quantitative research methods and basic statistics. It uses a detective theme throughout the text and in multimedia courseware to show how quantitative methods have been used to solve real-life problems. The book focuses on principles and techniques that are appropriate to introductory level courses in media, psychology and sociology. Examples and illustrations are drawn from historical and contemporary research in the social sciences. The multimedia courseware provides tutorial work on sampling, basic statistics, and techniques for seeking information from databases and other sources. The statistics modules can be used as either part of a detective games or directly in teaching and learning. Brief video lessons in SPSS, using real datasets, are also a feature of the CD-ROM.

  1. Mathematical Rigor in Introductory Physics

    Science.gov (United States)

    Vandyke, Michael; Bassichis, William

    2011-10-01

    Calculus-based introductory physics courses intended for future engineers and physicists are often designed and taught in the same fashion as those intended for students of other disciplines. A more mathematically rigorous curriculum should be more appropriate and, ultimately, more beneficial for the student in his or her future coursework. This work investigates the effects of mathematical rigor on student understanding of introductory mechanics. Using a series of diagnostic tools in conjunction with individual student course performance, a statistical analysis will be performed to examine student learning of introductory mechanics and its relation to student understanding of the underlying calculus.

  2. ATP, IMP, and glycogen in cod muscle at onset and during development of rigor mortis depend on the sampling location

    DEFF Research Database (Denmark)

    Cappeln, Gertrud; Jessen, Flemming

    2002-01-01

    Variation in glycogen, ATP, and IMP contents within individual cod muscles were studied in ice stored fish during the progress of rigor mortis. Rigor index was determined before muscle samples for chemical analyzes were taken at 16 different positions on the fish. During development of rigor......, the contents of glycogen and ATP decreased differently in relation to rigor index depending on sampling location. Although fish were considered to be in strong rigor according to the rigor index method, parts of the muscle were not in rigor as high ATP concentrations were found in dorsal and tall muscle....

  3. "Rigor mortis" in a live patient.

    Science.gov (United States)

    Chakravarthy, Murali

    2010-03-01

    Rigor mortis is conventionally a postmortem change. Its occurrence suggests that death has occurred at least a few hours ago. The authors report a case of "Rigor Mortis" in a live patient after cardiac surgery. The likely factors that may have predisposed such premortem muscle stiffening in the reported patient are, intense low cardiac output status, use of unusually high dose of inotropic and vasopressor agents and likely sepsis. Such an event may be of importance while determining the time of death in individuals such as described in the report. It may also suggest requirement of careful examination of patients with muscle stiffening prior to declaration of death. This report is being published to point out the likely controversies that might arise out of muscle stiffening, which should not always be termed rigor mortis and/ or postmortem.

  4. Classroom Talk for Rigorous Reading Comprehension Instruction

    Science.gov (United States)

    Wolf, Mikyung Kim; Crosson, Amy C.; Resnick, Lauren B.

    2004-01-01

    This study examined the quality of classroom talk and its relation to academic rigor in reading-comprehension lessons. Additionally, the study aimed to characterize effective questions to support rigorous reading comprehension lessons. The data for this study included 21 reading-comprehension lessons in several elementary and middle schools from…

  5. Quantitative Approaches to Group Research: Suggestions for Best Practices

    Science.gov (United States)

    McCarthy, Christopher J.; Whittaker, Tiffany A.; Boyle, Lauren H.; Eyal, Maytal

    2017-01-01

    Rigorous scholarship is essential to the continued growth of group work, yet the unique nature of this counseling specialty poses challenges for quantitative researchers. The purpose of this proposal is to overview unique challenges to quantitative research with groups in the counseling field, including difficulty in obtaining large sample sizes…

  6. The Relationship between Student's Quantitative Skills, Application of Math, Science Courses, and Science Marks at Single-Sex Independent High Schools

    Science.gov (United States)

    Cambridge, David

    2012-01-01

    For independent secondary schools who offer rigorous curriculum to attract students, integration of quantitative skills in the science courses has become an important definition of rigor. However, there is little research examining students' quantitative skills in relation to high school science performance within the single-sex independent school…

  7. pd Scattering Using a Rigorous Coulomb Treatment: Reliability of the Renormalization Method for Screened-Coulomb Potentials

    International Nuclear Information System (INIS)

    Hiratsuka, Y.; Oryu, S.; Gojuki, S.

    2011-01-01

    Reliability of the screened Coulomb renormalization method, which was proposed in an elegant way by Alt-Sandhas-Zankel-Ziegelmann (ASZZ), is discussed on the basis of 'two-potential theory' for the three-body AGS equations with the Coulomb potential. In order to obtain ASZZ's formula, we define the on-shell Moller function, and calculate it by using the Haeringen criterion, i. e. 'the half-shell Coulomb amplitude is zero'. By these two steps, we can finally obtain the ASZZ formula for a small Coulomb phase shift. Furthermore, the reliability of the Haeringen criterion is thoroughly checked by a numerically rigorous calculation for the Coulomb LS-type equation. We find that the Haeringen criterion can be satisfied only in the higher energy region. We conclude that the ASZZ method can be verified in the case that the on-shell approximation to the Moller function is reasonable, and the Haeringen criterion is reliable. (author)

  8. [A new formula for the measurement of rigor mortis: the determination of the FRR-index (author's transl)].

    Science.gov (United States)

    Forster, B; Ropohl, D; Raule, P

    1977-07-05

    The manual examination of rigor mortis as currently used and its often subjective evaluation frequently produced highly incorrect deductions. It is therefore desirable that such inaccuracies should be replaced by the objective measuring of rigor mortis at the extremities. To that purpose a method is described which can also be applied in on-the-spot investigations and a new formula for the determination of rigor mortis--indices (FRR) is introduced.

  9. Nuclear medicine and imaging research (instrumentation and quantitative methods of evaluation)

    International Nuclear Information System (INIS)

    Beck, R.N.; Cooper, M.; Chen, C.T.

    1992-07-01

    This document is the annual progress report for project entitled ''Instrumentation and Quantitative Methods of Evaluation.'' Progress is reported in separate sections individually abstracted and indexed for the database. Subject areas reported include theoretical studies of imaging systems and methods, hardware developments, quantitative methods of evaluation, and knowledge transfer: education in quantitative nuclear medicine imaging

  10. [Experimental study of restiffening of the rigor mortis].

    Science.gov (United States)

    Wang, X; Li, M; Liao, Z G; Yi, X F; Peng, X M

    2001-11-01

    To observe changes of the length of sarcomere of rat when restiffening. We measured the length of sarcomere of quadriceps in 40 rats in different condition by scanning electron microscope. The length of sarcomere of rigor mortis without destroy is obviously shorter than that of restiffening. The length of sarcomere is negatively correlative to the intensity of rigor mortis. Measuring the length of sarcomere can determine the intensity of rigor mortis and provide evidence for estimation of time since death.

  11. [Rigor mortis -- a definite sign of death?].

    Science.gov (United States)

    Heller, A R; Müller, M P; Frank, M D; Dressler, J

    2005-04-01

    In the past years an ongoing controversial debate exists in Germany, regarding quality of the coroner's inquest and declaration of death by physicians. We report the case of a 90-year old female, who was found after an unknown time following a suicide attempt with benzodiazepine. The examination of the patient showed livores (mortis?) on the left forearm and left lower leg. Moreover, rigor (mortis?) of the left arm was apparent which prevented arm flexion and extension. The hypothermic patient with insufficient respiration was intubated and mechanically ventilated. Chest compressions were not performed, because central pulses were (hardly) palpable and a sinus bradycardia 45/min (AV-block 2 degrees and sole premature ventricular complexes) was present. After placement of an intravenous line (17 G, external jugular vein) the hemodynamic situation was stabilized with intermittent boli of epinephrine and with sodium bicarbonate. With improved circulation livores and rigor disappeared. In the present case a minimal central circulation was noted, which could be stabilized, despite the presence of certain signs of death ( livores and rigor mortis). Considering the finding of an abrogated peripheral perfusion (livores), we postulate a centripetal collapse of glycogen and ATP supply in the patients left arm (rigor), which was restored after resuscitation and reperfusion. Thus, it appears that livores and rigor are not sensitive enough to exclude a vita minima, in particular in hypothermic patients with intoxications. Consequently a careful ABC-check should be performed even in the presence of apparently certain signs of death, to avoid underdiagnosing a vita minima. Additional ECG- monitoring is required to reduce the rate of false positive declarations of death. To what extent basic life support by paramedics should commence when rigor and livores are present until physician DNR order, deserves further discussion.

  12. Development of Three Methods for Simultaneous Quantitative ...

    African Journals Online (AJOL)

    Development of Three Methods for Simultaneous Quantitative Determination of Chlorpheniramine Maleate and Dexamethasone in the Presence of Parabens in ... Tropical Journal of Pharmaceutical Research ... Results: All the proposed methods were successfully applied to the analysis of raw materials and dosage form.

  13. Qualitative Methods in Mental Health Services Research

    Science.gov (United States)

    Palinkas, Lawrence A.

    2014-01-01

    Qualitative and mixed methods play a prominent role in mental health services research. However, the standards for their use are not always evident, especially for those not trained in such methods. This paper reviews the rationale and common approaches to using qualitative and mixed methods in mental health services and implementation research based on a review of the papers included in this special series along with representative examples from the literature. Qualitative methods are used to provide a “thick description” or depth of understanding to complement breadth of understanding afforded by quantitative methods, elicit the perspective of those being studied, explore issues that have not been well studied, develop conceptual theories or test hypotheses, or evaluate the process of a phenomenon or intervention. Qualitative methods adhere to many of the same principles of scientific rigor as quantitative methods, but often differ with respect to study design, data collection and data analysis strategies. For instance, participants for qualitative studies are usually sampled purposefully rather than at random and the design usually reflects an iterative process alternating between data collection and analysis. The most common techniques for data collection are individual semi-structured interviews, focus groups, document reviews, and participant observation. Strategies for analysis are usually inductive, based on principles of grounded theory or phenomenology. Qualitative methods are also used in combination with quantitative methods in mixed method designs for convergence, complementarity, expansion, development, and sampling. Rigorously applied qualitative methods offer great potential in contributing to the scientific foundation of mental health services research. PMID:25350675

  14. A CT-based method for fully quantitative TI SPECT

    International Nuclear Information System (INIS)

    Willowson, Kathy; Bailey, Dale; Baldock, Clive

    2009-01-01

    Full text: Objectives: To develop and validate a method for quantitative 2 0 l TI SPECT data based on corrections derived from X-ray CT data, and to apply the method in the clinic for quantitative determination of recurrence of brain tumours. Method: A previously developed method for achieving quantitative SPECT with 9 9 m Tc based on corrections derived from xray CT data was extended to apply to 2 0 l Tl. Experimental validation was performed on a cylindrical phantom by comparing known injected activity and measured concentration to quantitative calculations. Further evaluation was performed on a RSI Striatal Brain Phantom containing three 'lesions' with activity to background ratios of 1: 1, 1.5: I and 2: I. The method was subsequently applied to a series of scans from patients with suspected recurrence of brain tumours (principally glioma) to determine an SUV-like measure (Standardised Uptake Value). Results: The total activity and concentration in the phantom were calculated to within 3% and I % of the true values, respectively. The calculated values for the concentration of activity in the background and corresponding lesions of the brain phantom (in increasing ratios) were found to be within 2%,10%,1% and 2%, respectively, of the true concentrations. Patient studies showed that an initial SUV greater than 1.5 corresponded to a 56% mortality rate in the first 12 months, as opposed to a 14% mortality rate for those with a SUV less than 1.5. Conclusion: The quantitative technique produces accurate results for the radionuclide 2 0 l Tl. Initial investigation in clinical brain SPECT suggests correlation between quantitative uptake and survival.

  15. Rigorous high-precision enclosures of fixed points and their invariant manifolds

    Science.gov (United States)

    Wittig, Alexander N.

    The well established concept of Taylor Models is introduced, which offer highly accurate C0 enclosures of functional dependencies, combining high-order polynomial approximation of functions and rigorous estimates of the truncation error, performed using verified arithmetic. The focus of this work is on the application of Taylor Models in algorithms for strongly non-linear dynamical systems. A method is proposed to extend the existing implementation of Taylor Models in COSY INFINITY from double precision coefficients to arbitrary precision coefficients. Great care is taken to maintain the highest efficiency possible by adaptively adjusting the precision of higher order coefficients in the polynomial expansion. High precision operations are based on clever combinations of elementary floating point operations yielding exact values for round-off errors. An experimental high precision interval data type is developed and implemented. Algorithms for the verified computation of intrinsic functions based on the High Precision Interval datatype are developed and described in detail. The application of these operations in the implementation of High Precision Taylor Models is discussed. An application of Taylor Model methods to the verification of fixed points is presented by verifying the existence of a period 15 fixed point in a near standard Henon map. Verification is performed using different verified methods such as double precision Taylor Models, High Precision intervals and High Precision Taylor Models. Results and performance of each method are compared. An automated rigorous fixed point finder is implemented, allowing the fully automated search for all fixed points of a function within a given domain. It returns a list of verified enclosures of each fixed point, optionally verifying uniqueness within these enclosures. An application of the fixed point finder to the rigorous analysis of beam transfer maps in accelerator physics is presented. Previous work done by

  16. Monitoring muscle optical scattering properties during rigor mortis

    Science.gov (United States)

    Xia, J.; Ranasinghesagara, J.; Ku, C. W.; Yao, G.

    2007-09-01

    Sarcomere is the fundamental functional unit in skeletal muscle for force generation. In addition, sarcomere structure is also an important factor that affects the eating quality of muscle food, the meat. The sarcomere structure is altered significantly during rigor mortis, which is the critical stage involved in transforming muscle to meat. In this paper, we investigated optical scattering changes during the rigor process in Sternomandibularis muscles. The measured optical scattering parameters were analyzed along with the simultaneously measured passive tension, pH value, and histology analysis. We found that the temporal changes of optical scattering, passive tension, pH value and fiber microstructures were closely correlated during the rigor process. These results suggested that sarcomere structure changes during rigor mortis can be monitored and characterized by optical scattering, which may find practical applications in predicting meat quality.

  17. Comprehensive methods for earlier detection and monitoring of forest decline

    Science.gov (United States)

    Jennifer Pontius; Richard Hallett

    2014-01-01

    Forested ecosystems are threatened by invasive pests, pathogens, and unusual climatic events brought about by climate change. Earlier detection of incipient forest health problems and a quantitatively rigorous assessment method is increasingly important. Here, we describe a method that is adaptable across tree species and stress agents and practical for use in the...

  18. Rigorous simulations of a helical core fiber by the use of transformation optics formalism.

    Science.gov (United States)

    Napiorkowski, Maciej; Urbanczyk, Waclaw

    2014-09-22

    We report for the first time on rigorous numerical simulations of a helical-core fiber by using a full vectorial method based on the transformation optics formalism. We modeled the dependence of circular birefringence of the fundamental mode on the helix pitch and analyzed the effect of a birefringence increase caused by the mode displacement induced by a core twist. Furthermore, we analyzed the complex field evolution versus the helix pitch in the first order modes, including polarization and intensity distribution. Finally, we show that the use of the rigorous vectorial method allows to better predict the confinement loss of the guided modes compared to approximate methods based on equivalent in-plane bending models.

  19. [Reconstituting evaluation methods based on both qualitative and quantitative paradigms].

    Science.gov (United States)

    Miyata, Hiroaki; Okubo, Suguru; Yoshie, Satoru; Kai, Ichiro

    2011-01-01

    Debate about the relationship between quantitative and qualitative paradigms is often muddled and confusing and the clutter of terms and arguments has resulted in the concepts becoming obscure and unrecognizable. In this study we conducted content analysis regarding evaluation methods of qualitative healthcare research. We extracted descriptions on four types of evaluation paradigm (validity/credibility, reliability/credibility, objectivity/confirmability, and generalizability/transferability), and classified them into subcategories. In quantitative research, there has been many evaluation methods based on qualitative paradigms, and vice versa. Thus, it might not be useful to consider evaluation methods of qualitative paradigm are isolated from those of quantitative methods. Choosing practical evaluation methods based on the situation and prior conditions of each study is an important approach for researchers.

  20. Quantitative analysis method for ship construction quality

    Directory of Open Access Journals (Sweden)

    FU Senzong

    2017-03-01

    Full Text Available The excellent performance of a ship is assured by the accurate evaluation of its construction quality. For a long time, research into the construction quality of ships has mainly focused on qualitative analysis due to a shortage of process data, which results from limited samples, varied process types and non-standardized processes. Aiming at predicting and controlling the influence of the construction process on the construction quality of ships, this article proposes a reliability quantitative analysis flow path for the ship construction process and fuzzy calculation method. Based on the process-quality factor model proposed by the Function-Oriented Quality Control (FOQC method, we combine fuzzy mathematics with the expert grading method to deduce formulations calculating the fuzzy process reliability of the ordinal connection model, series connection model and mixed connection model. The quantitative analysis method is applied in analyzing the process reliability of a ship's shaft gear box installation, which proves the applicability and effectiveness of the method. The analysis results can be a useful reference for setting key quality inspection points and optimizing key processes.

  1. A General Method for Targeted Quantitative Cross-Linking Mass Spectrometry.

    Directory of Open Access Journals (Sweden)

    Juan D Chavez

    Full Text Available Chemical cross-linking mass spectrometry (XL-MS provides protein structural information by identifying covalently linked proximal amino acid residues on protein surfaces. The information gained by this technique is complementary to other structural biology methods such as x-ray crystallography, NMR and cryo-electron microscopy[1]. The extension of traditional quantitative proteomics methods with chemical cross-linking can provide information on the structural dynamics of protein structures and protein complexes. The identification and quantitation of cross-linked peptides remains challenging for the general community, requiring specialized expertise ultimately limiting more widespread adoption of the technique. We describe a general method for targeted quantitative mass spectrometric analysis of cross-linked peptide pairs. We report the adaptation of the widely used, open source software package Skyline, for the analysis of quantitative XL-MS data as a means for data analysis and sharing of methods. We demonstrate the utility and robustness of the method with a cross-laboratory study and present data that is supported by and validates previously published data on quantified cross-linked peptide pairs. This advance provides an easy to use resource so that any lab with access to a LC-MS system capable of performing targeted quantitative analysis can quickly and accurately measure dynamic changes in protein structure and protein interactions.

  2. Imprecise Probability Methods for Weapons UQ

    Energy Technology Data Exchange (ETDEWEB)

    Picard, Richard Roy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Vander Wiel, Scott Alan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-13

    Building on recent work in uncertainty quanti cation, we examine the use of imprecise probability methods to better characterize expert knowledge and to improve on misleading aspects of Bayesian analysis with informative prior distributions. Quantitative approaches to incorporate uncertainties in weapons certi cation are subject to rigorous external peer review, and in this regard, certain imprecise probability methods are well established in the literature and attractive. These methods are illustrated using experimental data from LANL detonator impact testing.

  3. Evaluating Rigor in Qualitative Methodology and Research Dissemination

    Science.gov (United States)

    Trainor, Audrey A.; Graue, Elizabeth

    2014-01-01

    Despite previous and successful attempts to outline general criteria for rigor, researchers in special education have debated the application of rigor criteria, the significance or importance of small n research, the purpose of interpretivist approaches, and the generalizability of qualitative empirical results. Adding to these complications, the…

  4. Mixed Methods in Biomedical and Health Services Research

    OpenAIRE

    Curry, Leslie A.; Krumholz, Harlan M.; O’Cathain, Alicia; Plano Clark, Vicki L.; Cherlin, Emily; Bradley, Elizabeth H.

    2013-01-01

    Mixed methods studies, in which qualitative and quantitative methods are combined in a single program of inquiry, can be valuable in biomedical and health services research, where the complementary strengths of each approach can yield greater insight into complex phenomena than either approach alone. Although interest in mixed methods is growing among science funders and investigators, written guidance on how to conduct and assess rigorous mixed methods studies is not readily accessible to th...

  5. A Quantitative Method for Localizing User Interface Problems: The D-TEO Method

    Directory of Open Access Journals (Sweden)

    Juha Lamminen

    2009-01-01

    Full Text Available A large array of evaluation methods have been proposed to identify Website usability problems. In log-based evaluation, information about the performance of users is collected and stored into log files, and used to find problems and deficiencies in Web page designs. Most methods require the programming and modeling of large task models, which are cumbersome processes for evaluators. Also, because much statistical data is collected onto log files, recognizing which Web pages require deeper usability analysis is difficult. This paper suggests a novel quantitative method, called the D-TEO, for locating problematic Web pages. This semiautomated method explores the decomposition of interaction tasks of directed information search into elementary operations, deploying two quantitative usability criteria, search success and search time, to reveal how a user navigates within a web of hypertext.

  6. Student’s rigorous mathematical thinking based on cognitive style

    Science.gov (United States)

    Fitriyani, H.; Khasanah, U.

    2017-12-01

    The purpose of this research was to determine the rigorous mathematical thinking (RMT) of mathematics education students in solving math problems in terms of reflective and impulsive cognitive styles. The research used descriptive qualitative approach. Subjects in this research were 4 students of the reflective and impulsive cognitive style which was each consisting male and female subjects. Data collection techniques used problem-solving test and interview. Analysis of research data used Miles and Huberman model that was reduction of data, presentation of data, and conclusion. The results showed that impulsive male subjects used three levels of the cognitive function required for RMT that were qualitative thinking, quantitative thinking with precision, and relational thinking completely while the other three subjects were only able to use cognitive function at qualitative thinking level of RMT. Therefore the subject of impulsive male has a better RMT ability than the other three research subjects.

  7. B-ALL minimal residual disease flow cytometry: an application of a novel method for optimization of a single-tube model.

    Science.gov (United States)

    Shaver, Aaron C; Greig, Bruce W; Mosse, Claudio A; Seegmiller, Adam C

    2015-05-01

    Optimizing a clinical flow cytometry panel can be a subjective process dependent on experience. We develop a quantitative method to make this process more rigorous and apply it to B lymphoblastic leukemia/lymphoma (B-ALL) minimal residual disease (MRD) testing. We retrospectively analyzed our existing three-tube, seven-color B-ALL MRD panel and used our novel method to develop an optimized one-tube, eight-color panel, which was tested prospectively. The optimized one-tube, eight-color panel resulted in greater efficiency of time and resources with no loss in diagnostic power. Constructing a flow cytometry panel using a rigorous, objective, quantitative method permits optimization and avoids problems of interdependence and redundancy in a large, multiantigen panel. Copyright© by the American Society for Clinical Pathology.

  8. An ultramicroscopic study on rigor mortis.

    Science.gov (United States)

    Suzuki, T

    1976-01-01

    Gastrocnemius muscles taken from decapitated mice at various intervals after death and from mice killed by 2,4-dinitrophenol or mono-iodoacetic acid injection to induce rigor mortis soon after death, were observed by electron microscopy. The prominent appearance of many fine cross striations in the myofibrils (occurring about every 400 A) was considered to be characteristic of rigor mortis. These striations were caused by minute granules studded along the surfaces of both thick and thin filaments and appeared to be the bridges connecting the 2 kinds of filaments and accounted for the hardness and rigidity of the muscle.

  9. A Review of Mixed Methods Research on Bullying and Peer Victimization in School

    Science.gov (United States)

    Hong, Jun Sung; Espelage, Dorothy L.

    2012-01-01

    Recognizing the negative outcomes associated with experiences in bullying at school, educational researchers, school officials, and policy-makers have called for more rigorous research on bullying in school. Research on bullying behavior in school has primarily been examined using quantitative methods. Mixed methods research in the field of…

  10. Studying learning in the healthcare setting: the potential of quantitative diary methods.

    Science.gov (United States)

    Ciere, Yvette; Jaarsma, Debbie; Visser, Annemieke; Sanderman, Robbert; Snippe, Evelien; Fleer, Joke

    2015-08-01

    Quantitative diary methods are longitudinal approaches that involve the repeated measurement of aspects of peoples' experience of daily life. In this article, we outline the main characteristics and applications of quantitative diary methods and discuss how their use may further research in the field of medical education. Quantitative diary methods offer several methodological advantages, such as measuring aspects of learning with great detail, accuracy and authenticity. Moreover, they enable researchers to study how and under which conditions learning in the health care setting occurs and in which way learning can be promoted. Hence, quantitative diary methods may contribute to theory development and the optimization of teaching methods in medical education.

  11. Differential algebras with remainder and rigorous proofs of long-term stability

    International Nuclear Information System (INIS)

    Berz, Martin

    1997-01-01

    It is shown how in addition to determining Taylor maps of general optical systems, it is possible to obtain rigorous interval bounds for the remainder term of the n-th order Taylor expansion. To this end, the three elementary operations of addition, multiplication, and differentiation in the Differential Algebraic approach are augmented by suitable interval operations in such a way that a remainder bound of the sum, product, and derivative is obtained from the Taylor polynomial and remainder bound of the operands. The method can be used to obtain bounds for the accuracy with which a Taylor map represents the true map of the particle optical system. In a more general sense, it is also useful for a variety of other numerical problems, including rigorous global optimization of highly complex functions. Combined with methods to obtain pseudo-invariants of repetitive motion and extensions of the Lyapunov- and Nekhoroshev stability theory, the latter can be used to guarantee stability for storage rings and other weakly nonlinear systems

  12. Optimization method for quantitative calculation of clay minerals in soil

    Indian Academy of Sciences (India)

    However, no reliable method for quantitative analysis of clay minerals has been established so far. In this study, an attempt was made to propose an optimization method for the quantitative ... 2. Basic principles. The mineralogical constitution of soil is rather complex. ... K2O, MgO, and TFe as variables for the calculation.

  13. A Rigorous Methodology for Analyzing and Designing Plug-Ins

    DEFF Research Database (Denmark)

    Fasie, Marieta V.; Haxthausen, Anne Elisabeth; Kiniry, Joseph

    2013-01-01

    . This paper addresses these problems by describing a rigorous methodology for analyzing and designing plug-ins. The methodology is grounded in the Extended Business Object Notation (EBON) and covers informal analysis and design of features, GUI, actions, and scenarios, formal architecture design, including...... behavioral semantics, and validation. The methodology is illustrated via a case study whose focus is an Eclipse environment for the RAISE formal method's tool suite....

  14. Sample normalization methods in quantitative metabolomics.

    Science.gov (United States)

    Wu, Yiman; Li, Liang

    2016-01-22

    To reveal metabolomic changes caused by a biological event in quantitative metabolomics, it is critical to use an analytical tool that can perform accurate and precise quantification to examine the true concentration differences of individual metabolites found in different samples. A number of steps are involved in metabolomic analysis including pre-analytical work (e.g., sample collection and storage), analytical work (e.g., sample analysis) and data analysis (e.g., feature extraction and quantification). Each one of them can influence the quantitative results significantly and thus should be performed with great care. Among them, the total sample amount or concentration of metabolites can be significantly different from one sample to another. Thus, it is critical to reduce or eliminate the effect of total sample amount variation on quantification of individual metabolites. In this review, we describe the importance of sample normalization in the analytical workflow with a focus on mass spectrometry (MS)-based platforms, discuss a number of methods recently reported in the literature and comment on their applicability in real world metabolomics applications. Sample normalization has been sometimes ignored in metabolomics, partially due to the lack of a convenient means of performing sample normalization. We show that several methods are now available and sample normalization should be performed in quantitative metabolomics where the analyzed samples have significant variations in total sample amounts. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Electric Field Quantitative Measurement System and Method

    Science.gov (United States)

    Generazio, Edward R. (Inventor)

    2016-01-01

    A method and system are provided for making a quantitative measurement of an electric field. A plurality of antennas separated from one another by known distances are arrayed in a region that extends in at least one dimension. A voltage difference between at least one selected pair of antennas is measured. Each voltage difference is divided by the known distance associated with the selected pair of antennas corresponding thereto to generate a resulting quantity. The plurality of resulting quantities defined over the region quantitatively describe an electric field therein.

  16. Development of interface between MCNP-FISPACT-MCNP (IPR-MFM) based on rigorous two step method

    International Nuclear Information System (INIS)

    Shaw, A.K.; Swami, H.L.; Danani, C.

    2015-01-01

    In this work we present the development of interface tool between MCNP-FISPACT-MCNP (MFM) based on Rigorous Two Step method for the shutdown dose rate (SDDR) calculation. The MFM links MCNP radiation transport and the FISPACT inventory code through a suitable coupling scheme. MFM coupling scheme has three steps. In first step it picks neutron spectrum and total flux from MCNP output file to use as input parameter for FISPACT. It prepares the FISPACT input files by using irradiation history, neutron flux and neutron spectrum and then execute the FISPACT input file in the second step. Third step of MFM coupling scheme extracts the decay gammas from the FISPACT output file and prepares MCNP input file for decay gamma transport followed by execution of MCNP input file and estimation of SDDR. Here detailing of MFM methodology and flow scheme has been described. The programming language PYTHON has been chosen for this development of the coupling scheme. A complete loop of MCNP-FISPACT-MCNP has been developed to handle the simplified geometrical problems. For validation of MFM interface a manual cross-check has been performed which shows good agreements. The MFM interface also has been validated with exiting MCNP-D1S method for a simple geometry with 14 MeV cylindrical neutron source. (author)

  17. Distance-based microfluidic quantitative detection methods for point-of-care testing.

    Science.gov (United States)

    Tian, Tian; Li, Jiuxing; Song, Yanling; Zhou, Leiji; Zhu, Zhi; Yang, Chaoyong James

    2016-04-07

    Equipment-free devices with quantitative readout are of great significance to point-of-care testing (POCT), which provides real-time readout to users and is especially important in low-resource settings. Among various equipment-free approaches, distance-based visual quantitative detection methods rely on reading the visual signal length for corresponding target concentrations, thus eliminating the need for sophisticated instruments. The distance-based methods are low-cost, user-friendly and can be integrated into portable analytical devices. Moreover, such methods enable quantitative detection of various targets by the naked eye. In this review, we first introduce the concept and history of distance-based visual quantitative detection methods. Then, we summarize the main methods for translation of molecular signals to distance-based readout and discuss different microfluidic platforms (glass, PDMS, paper and thread) in terms of applications in biomedical diagnostics, food safety monitoring, and environmental analysis. Finally, the potential and future perspectives are discussed.

  18. [A new method of processing quantitative PCR data].

    Science.gov (United States)

    Ke, Bing-Shen; Li, Guang-Yun; Chen, Shi-Min; Huang, Xiang-Yan; Chen, Ying-Jian; Xu, Jun

    2003-05-01

    Today standard PCR can't satisfy the need of biotechnique development and clinical research any more. After numerous dynamic research, PE company found there is a linear relation between initial template number and cycling time when the accumulating fluorescent product is detectable.Therefore,they developed a quantitative PCR technique to be used in PE7700 and PE5700. But the error of this technique is too great to satisfy the need of biotechnique development and clinical research. A better quantitative PCR technique is needed. The mathematical model submitted here is combined with the achievement of relative science,and based on the PCR principle and careful analysis of molecular relationship of main members in PCR reaction system. This model describes the function relation between product quantity or fluorescence intensity and initial template number and other reaction conditions, and can reflect the accumulating rule of PCR product molecule accurately. Accurate quantitative PCR analysis can be made use this function relation. Accumulated PCR product quantity can be obtained from initial template number. Using this model to do quantitative PCR analysis,result error is only related to the accuracy of fluorescence intensity or the instrument used. For an example, when the fluorescence intensity is accurate to 6 digits and the template size is between 100 to 1,000,000, the quantitative result accuracy will be more than 99%. The difference of result error is distinct using same condition,same instrument but different analysis method. Moreover,if the PCR quantitative analysis system is used to process data, it will get result 80 times of accuracy than using CT method.

  19. Quantitative EEG Applying the Statistical Recognition Pattern Method

    DEFF Research Database (Denmark)

    Engedal, Knut; Snaedal, Jon; Hoegh, Peter

    2015-01-01

    BACKGROUND/AIM: The aim of this study was to examine the discriminatory power of quantitative EEG (qEEG) applying the statistical pattern recognition (SPR) method to separate Alzheimer's disease (AD) patients from elderly individuals without dementia and from other dementia patients. METHODS...

  20. Original methods of quantitative analysis developed for diverse samples in various research fields. Quantitative analysis at NMCC

    International Nuclear Information System (INIS)

    Sera, Koichiro

    2003-01-01

    Nishina Memorial Cyclotron Center (NMCC) has been opened for nationwide-common utilization of positron nuclear medicine (PET) and PIXE since April 1993. At the present time, nearly 40 subjects of PIXE in various research fields are pursued here, and more than 50,000 samples have been analyzed up to the present. In order to perform quantitative analyses of diverse samples, technical developments in sample preparation, measurement and data analysis have been continuously carried out. Especially, a standard-free method for quantitative analysis'' made it possible to perform analysis of infinitesimal samples, powdered samples and untreated bio samples, which could not be well analyzed quantitatively in the past. The standard-free method'' and a ''powdered internal standard method'' made the process for target preparation quite easier. It has been confirmed that results obtained by these methods show satisfactory accuracy and reproducibility preventing any ambiguity coming from complicated target preparation processes. (author)

  1. Mixing Methods in Instructional Research. Forum: The Future of Instructional Communication

    Science.gov (United States)

    Meluch, Andrea L.

    2017-01-01

    "Communication Education's" commitment to publishing rigorous instructional communication research with a diversity of methods is clear in its publication of quantitative, qualitative, and critical articles (Witt, 2012). Here, Andrea Meluch argues that the trends in the most recent research published within this journal indicate a lack…

  2. Experimental evaluation of rigor mortis. VIII. Estimation of time since death by repeated measurements of the intensity of rigor mortis on rats.

    Science.gov (United States)

    Krompecher, T

    1994-10-21

    The development of the intensity of rigor mortis was monitored in nine groups of rats. The measurements were initiated after 2, 4, 5, 6, 8, 12, 15, 24, and 48 h post mortem (p.m.) and lasted 5-9 h, which ideally should correspond to the usual procedure after the discovery of a corpse. The experiments were carried out at an ambient temperature of 24 degrees C. Measurements initiated early after death resulted in curves with a rising portion, a plateau, and a descending slope. Delaying the initial measurement translated into shorter rising portions, and curves initiated 8 h p.m. or later are comprised of a plateau and/or a downward slope only. Three different phases were observed suggesting simple rules that can help estimate the time since death: (1) if an increase in intensity was found, the initial measurements were conducted not later than 5 h p.m.; (2) if only a decrease in intensity was observed, the initial measurements were conducted not earlier than 7 h p.m.; and (3) at 24 h p.m., the resolution is complete, and no further changes in intensity should occur. Our results clearly demonstrate that repeated measurements of the intensity of rigor mortis allow a more accurate estimation of the time since death of the experimental animals than the single measurement method used earlier. A critical review of the literature on the estimation of time since death on the basis of objective measurements of the intensity of rigor mortis is also presented.

  3. Implementation of rigorous renormalization group method for ground space and low-energy states of local Hamiltonians

    Science.gov (United States)

    Roberts, Brenden; Vidick, Thomas; Motrunich, Olexei I.

    2017-12-01

    The success of polynomial-time tensor network methods for computing ground states of certain quantum local Hamiltonians has recently been given a sound theoretical basis by Arad et al. [Math. Phys. 356, 65 (2017), 10.1007/s00220-017-2973-z]. The convergence proof, however, relies on "rigorous renormalization group" (RRG) techniques which differ fundamentally from existing algorithms. We introduce a practical adaptation of the RRG procedure which, while no longer theoretically guaranteed to converge, finds matrix product state ansatz approximations to the ground spaces and low-lying excited spectra of local Hamiltonians in realistic situations. In contrast to other schemes, RRG does not utilize variational methods on tensor networks. Rather, it operates on subsets of the system Hilbert space by constructing approximations to the global ground space in a treelike manner. We evaluate the algorithm numerically, finding similar performance to density matrix renormalization group (DMRG) in the case of a gapped nondegenerate Hamiltonian. Even in challenging situations of criticality, large ground-state degeneracy, or long-range entanglement, RRG remains able to identify candidate states having large overlap with ground and low-energy eigenstates, outperforming DMRG in some cases.

  4. Emergency cricothyrotomy for trismus caused by instantaneous rigor in cardiac arrest patients.

    Science.gov (United States)

    Lee, Jae Hee; Jung, Koo Young

    2012-07-01

    Instantaneous rigor as muscle stiffening occurring in the moment of death (or cardiac arrest) can be confused with rigor mortis. If trismus is caused by instantaneous rigor, orotracheal intubation is impossible and a surgical airway should be secured. Here, we report 2 patients who had emergency cricothyrotomy for trismus caused by instantaneous rigor. This case report aims to help physicians understand instantaneous rigor and to emphasize the importance of securing a surgical airway quickly on the occurrence of trismus. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Mixed methods research design for pragmatic psychoanalytic studies.

    Science.gov (United States)

    Tillman, Jane G; Clemence, A Jill; Stevens, Jennifer L

    2011-10-01

    Calls for more rigorous psychoanalytic studies have increased over the past decade. The field has been divided by those who assert that psychoanalysis is properly a hermeneutic endeavor and those who see it as a science. A comparable debate is found in research methodology, where qualitative and quantitative methods have often been seen as occupying orthogonal positions. Recently, Mixed Methods Research (MMR) has emerged as a viable "third community" of research, pursuing a pragmatic approach to research endeavors through integrating qualitative and quantitative procedures in a single study design. Mixed Methods Research designs and the terminology associated with this emerging approach are explained, after which the methodology is explored as a potential integrative approach to a psychoanalytic human science. Both qualitative and quantitative research methods are reviewed, as well as how they may be used in Mixed Methods Research to study complex human phenomena.

  6. Rigor or mortis: best practices for preclinical research in neuroscience.

    Science.gov (United States)

    Steward, Oswald; Balice-Gordon, Rita

    2014-11-05

    Numerous recent reports document a lack of reproducibility of preclinical studies, raising concerns about potential lack of rigor. Examples of lack of rigor have been extensively documented and proposals for practices to improve rigor are appearing. Here, we discuss some of the details and implications of previously proposed best practices and consider some new ones, focusing on preclinical studies relevant to human neurological and psychiatric disorders. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Estimation of the time since death--reconsidering the re-establishment of rigor mortis.

    Science.gov (United States)

    Anders, Sven; Kunz, Michaela; Gehl, Axel; Sehner, Susanne; Raupach, Tobias; Beck-Bornholdt, Hans-Peter

    2013-01-01

    In forensic medicine, there is an undefined data background for the phenomenon of re-establishment of rigor mortis after mechanical loosening, a method used in establishing time since death in forensic casework that is thought to occur up to 8 h post-mortem. Nevertheless, the method is widely described in textbooks on forensic medicine. We examined 314 joints (elbow and knee) of 79 deceased at defined time points up to 21 h post-mortem (hpm). Data were analysed using a random intercept model. Here, we show that re-establishment occurred in 38.5% of joints at 7.5 to 19 hpm. Therefore, the maximum time span for the re-establishment of rigor mortis appears to be 2.5-fold longer than thought so far. These findings have major impact on the estimation of time since death in forensic casework.

  8. [Teaching quantitative methods in public health: the EHESP experience].

    Science.gov (United States)

    Grimaud, Olivier; Astagneau, Pascal; Desvarieux, Moïse; Chambaud, Laurent

    2014-01-01

    Many scientific disciplines, including epidemiology and biostatistics, are used in the field of public health. These quantitative sciences are fundamental tools necessary for the practice of future professionals. What then should be the minimum quantitative sciences training, common to all future public health professionals? By comparing the teaching models developed in Columbia University and those in the National School of Public Health in France, the authors recognize the need to adapt teaching to the specific competencies required for each profession. They insist that all public health professionals, whatever their future career, should be familiar with quantitative methods in order to ensure that decision-making is based on a reflective and critical use of quantitative analysis.

  9. Quantitative Preparation in Doctoral Education Programs: A Mixed-Methods Study of Doctoral Student Perspectives on their Quantitative Training

    Directory of Open Access Journals (Sweden)

    Sarah L Ferguson

    2017-07-01

    Full Text Available Aim/Purpose: The purpose of the current study is to explore student perceptions of their own doctoral-level education and quantitative proficiency. Background: The challenges of preparing doctoral students in education have been discussed in the literature, but largely from the perspective of university faculty and program administrators. The current study directly explores the student voice on this issue. Methodology: Utilizing a sequential explanatory mixed-methods research design, the present study seeks to better understand doctoral-level education students’ perceptions of their quantitative methods training at a large public university in the southwestern United States. Findings: Results from both phases present the need for more application and consistency in doctoral-level quantitative courses. Additionally, there was a consistent theme of internal motivation in the responses, suggesting students perceive their quantitative training to be valuable beyond their personal interest in the topic. Recommendations for Practitioners: Quantitative methods instructors should emphasize practice in their quantitative courses and consider providing additional support for students through the inclusion of lab sections, tutoring, and/or differentiation. Pre-testing statistical ability at the start of a course is also suggested to better meet student needs. Impact on Society: The ultimate goal of quantitative methods in doctoral education is to produce high-quality educational researchers who are prepared to apply their knowledge to problems and research in education. Results of the present study can inform faculty and administrator decisions in doctoral education to best support this goal. Future Research: Using the student perspectives presented in the present study, future researchers should continue to explore effective instructional strategies and curriculum design within education doctoral programs. The inclusion of student voice can strengthen

  10. Diffraction-based overlay measurement on dedicated mark using rigorous modeling method

    Science.gov (United States)

    Lu, Hailiang; Wang, Fan; Zhang, Qingyun; Chen, Yonghui; Zhou, Chang

    2012-03-01

    Diffraction Based Overlay (DBO) is widely evaluated by numerous authors, results show DBO can provide better performance than Imaging Based Overlay (IBO). However, DBO has its own problems. As well known, Modeling based DBO (mDBO) faces challenges of low measurement sensitivity and crosstalk between various structure parameters, which may result in poor accuracy and precision. Meanwhile, main obstacle encountered by empirical DBO (eDBO) is that a few pads must be employed to gain sufficient information on overlay-induced diffraction signature variations, which consumes more wafer space and costs more measuring time. Also, eDBO may suffer from mark profile asymmetry caused by processes. In this paper, we propose an alternative DBO technology that employs a dedicated overlay mark and takes a rigorous modeling approach. This technology needs only two or three pads for each direction, which is economic and time saving. While overlay measurement error induced by mark profile asymmetry being reduced, this technology is expected to be as accurate and precise as scatterometry technologies.

  11. Atlantic salmon skin and fillet color changes effected by perimortem handling stress, rigor mortis, and ice storage.

    Science.gov (United States)

    Erikson, U; Misimi, E

    2008-03-01

    The changes in skin and fillet color of anesthetized and exhausted Atlantic salmon were determined immediately after killing, during rigor mortis, and after ice storage for 7 d. Skin color (CIE L*, a*, b*, and related values) was determined by a Minolta Chroma Meter. Roche SalmoFan Lineal and Roche Color Card values were determined by a computer vision method and a sensory panel. Before color assessment, the stress levels of the 2 fish groups were characterized in terms of white muscle parameters (pH, rigor mortis, and core temperature). The results showed that perimortem handling stress initially significantly affected several color parameters of skin and fillets. Significant transient fillet color changes also occurred in the prerigor phase and during the development of rigor mortis. Our results suggested that fillet color was affected by postmortem glycolysis (pH drop, particularly in anesthetized fillets), then by onset and development of rigor mortis. The color change patterns during storage were different for the 2 groups of fish. The computer vision method was considered suitable for automated (online) quality control and grading of salmonid fillets according to color.

  12. Qualitative and mixed methods in mental health services and implementation research.

    Science.gov (United States)

    Palinkas, Lawrence A

    2014-01-01

    Qualitative and mixed methods play a prominent role in mental health services research. However, the standards for their use are not always evident, especially for those not trained in such methods. This article reviews the rationale and common approaches to using qualitative and mixed methods in mental health services and implementation research based on a review of the articles included in this special series along with representative examples from the literature. Qualitative methods are used to provide a "thick description" or depth of understanding to complement breadth of understanding afforded by quantitative methods, elicit the perspective of those being studied, explore issues that have not been well studied, develop conceptual theories or test hypotheses, or evaluate the process of a phenomenon or intervention. Qualitative methods adhere to many of the same principles of scientific rigor as quantitative methods but often differ with respect to study design, data collection, and data analysis strategies. For instance, participants for qualitative studies are usually sampled purposefully rather than at random and the design usually reflects an iterative process alternating between data collection and analysis. The most common techniques for data collection are individual semistructured interviews, focus groups, document reviews, and participant observation. Strategies for analysis are usually inductive, based on principles of grounded theory or phenomenology. Qualitative methods are also used in combination with quantitative methods in mixed-method designs for convergence, complementarity, expansion, development, and sampling. Rigorously applied qualitative methods offer great potential in contributing to the scientific foundation of mental health services research.

  13. ADVANCING THE STUDY OF VIOLENCE AGAINST WOMEN USING MIXED METHODS: INTEGRATING QUALITATIVE METHODS INTO A QUANTITATIVE RESEARCH PROGRAM

    Science.gov (United States)

    Testa, Maria; Livingston, Jennifer A.; VanZile-Tamsen, Carol

    2011-01-01

    A mixed methods approach, combining quantitative with qualitative data methods and analysis, offers a promising means of advancing the study of violence. Integrating semi-structured interviews and qualitative analysis into a quantitative program of research on women’s sexual victimization has resulted in valuable scientific insight and generation of novel hypotheses for testing. This mixed methods approach is described and recommendations for integrating qualitative data into quantitative research are provided. PMID:21307032

  14. Rigorous time slicing approach to Feynman path integrals

    CERN Document Server

    Fujiwara, Daisuke

    2017-01-01

    This book proves that Feynman's original definition of the path integral actually converges to the fundamental solution of the Schrödinger equation at least in the short term if the potential is differentiable sufficiently many times and its derivatives of order equal to or higher than two are bounded. The semi-classical asymptotic formula up to the second term of the fundamental solution is also proved by a method different from that of Birkhoff. A bound of the remainder term is also proved. The Feynman path integral is a method of quantization using the Lagrangian function, whereas Schrödinger's quantization uses the Hamiltonian function. These two methods are believed to be equivalent. But equivalence is not fully proved mathematically, because, compared with Schrödinger's method, there is still much to be done concerning rigorous mathematical treatment of Feynman's method. Feynman himself defined a path integral as the limit of a sequence of integrals over finite-dimensional spaces which is obtained by...

  15. Calibration of quantitative neutron radiography method for moisture measurement

    International Nuclear Information System (INIS)

    Nemec, T.; Jeraj, R.

    1999-01-01

    Quantitative measurements of moisture and hydrogenous matter in building materials by neutron radiography (NR) are regularly performed at TRIGA Mark II research of 'Jozef Stefan' Institute in Ljubljana. Calibration of quantitative method is performed using standard brick samples with known moisture content and also with a secondary standard, plexiglas step wedge. In general, the contribution of scattered neutrons to the neutron image is not determined explicitly what introduces an error to the measured signal. Influence of scattered neutrons is significant in regions with high gradients of moisture concentrations, where the build up of scattered neutrons causes distortion of the moisture concentration profile. In this paper detailed analysis of validity of our calibration method for different geometrical parameters is presented. The error in the measured hydrogen concentration is evaluated by an experiment and compared with results obtained by Monte Carlo calculation with computer code MCNP 4B. Optimal conditions are determined for quantitative moisture measurements in order to minimize the error due to scattered neutrons. The method is tested on concrete samples with high moisture content.(author)

  16. The discussion on the qualitative and quantitative evaluation methods for safety culture

    International Nuclear Information System (INIS)

    Gao Kefu

    2005-01-01

    The fundamental methods for safely culture evaluation are described. Combining with the practice of the quantitative evaluation of safety culture in Daya Bay NPP, the quantitative evaluation method for safety culture are discussed. (author)

  17. Quantitative sociodynamics stochastic methods and models of social interaction processes

    CERN Document Server

    Helbing, Dirk

    1995-01-01

    Quantitative Sociodynamics presents a general strategy for interdisciplinary model building and its application to a quantitative description of behavioural changes based on social interaction processes. Originally, the crucial methods for the modeling of complex systems (stochastic methods and nonlinear dynamics) were developed in physics but they have very often proved their explanatory power in chemistry, biology, economics and the social sciences. Quantitative Sociodynamics provides a unified and comprehensive overview of the different stochastic methods, their interrelations and properties. In addition, it introduces the most important concepts from nonlinear dynamics (synergetics, chaos theory). The applicability of these fascinating concepts to social phenomena is carefully discussed. By incorporating decision-theoretical approaches a very fundamental dynamic model is obtained which seems to open new perspectives in the social sciences. It includes many established models as special cases, e.g. the log...

  18. Quantitative Sociodynamics Stochastic Methods and Models of Social Interaction Processes

    CERN Document Server

    Helbing, Dirk

    2010-01-01

    This new edition of Quantitative Sociodynamics presents a general strategy for interdisciplinary model building and its application to a quantitative description of behavioral changes based on social interaction processes. Originally, the crucial methods for the modeling of complex systems (stochastic methods and nonlinear dynamics) were developed in physics and mathematics, but they have very often proven their explanatory power in chemistry, biology, economics and the social sciences as well. Quantitative Sociodynamics provides a unified and comprehensive overview of the different stochastic methods, their interrelations and properties. In addition, it introduces important concepts from nonlinear dynamics (e.g. synergetics, chaos theory). The applicability of these fascinating concepts to social phenomena is carefully discussed. By incorporating decision-theoretical approaches, a fundamental dynamic model is obtained, which opens new perspectives in the social sciences. It includes many established models a...

  19. Statistical mechanics rigorous results

    CERN Document Server

    Ruelle, David

    1999-01-01

    This classic book marks the beginning of an era of vigorous mathematical progress in equilibrium statistical mechanics. Its treatment of the infinite system limit has not been superseded, and the discussion of thermodynamic functions and states remains basic for more recent work. The conceptual foundation provided by the Rigorous Results remains invaluable for the study of the spectacular developments of statistical mechanics in the second half of the 20th century.

  20. High and low rigor temperature effects on sheep meat tenderness and ageing.

    Science.gov (United States)

    Devine, Carrick E; Payne, Steven R; Peachey, Bridget M; Lowe, Timothy E; Ingram, John R; Cook, Christian J

    2002-02-01

    Immediately after electrical stimulation, the paired m. longissimus thoracis et lumborum (LT) of 40 sheep were boned out and wrapped tightly with a polyethylene cling film. One of the paired LT's was chilled in 15°C air to reach a rigor mortis (rigor) temperature of 18°C and the other side was placed in a water bath at 35°C and achieved rigor at this temperature. Wrapping reduced rigor shortening and mimicked meat left on the carcass. After rigor, the meat was aged at 15°C for 0, 8, 26 and 72 h and then frozen. The frozen meat was cooked to 75°C in an 85°C water bath and shear force values obtained from a 1×1 cm cross-section. The shear force values of meat for 18 and 35°C rigor were similar at zero ageing, but as ageing progressed, the 18 rigor meat aged faster and became more tender than meat that went into rigor at 35°C (Prigor at each ageing time were significantly different (Prigor were still significantly greater. Thus the toughness of 35°C meat was not a consequence of muscle shortening and appears to be due to both a faster rate of tenderisation and the meat tenderising to a greater extent at the lower temperature. The cook loss at 35°C rigor (30.5%) was greater than that at 18°C rigor (28.4%) (P<0.01) and the colour Hunter L values were higher at 35°C (P<0.01) compared with 18°C, but there were no significant differences in a or b values.

  1. Quantitative hyperbolicity estimates in one-dimensional dynamics

    International Nuclear Information System (INIS)

    Day, S; Kokubu, H; Pilarczyk, P; Luzzatto, S; Mischaikow, K; Oka, H

    2008-01-01

    We develop a rigorous computational method for estimating the Lyapunov exponents in uniformly expanding regions of the phase space for one-dimensional maps. Our method uses rigorous numerics and graph algorithms to provide results that are mathematically meaningful and can be achieved in an efficient way

  2. Physiological studies of muscle rigor mortis in the fowl

    International Nuclear Information System (INIS)

    Nakahira, S.; Kaneko, K.; Tanaka, K.

    1990-01-01

    A simple system was developed for continuous measurement of muscle contraction during nor mortis. Longitudinal muscle strips dissected from the Peroneus Longus were suspended in a plastic tube containing liquid paraffin. Mechanical activity was transmitted to a strain-gauge transducer which is connected to a potentiometric pen-recorder. At the onset of measurement 1.2g was loaded on the muscle strip. This model was used to study the muscle response to various treatments during nor mortis. All measurements were carried out under the anaerobic condition at 17°C, except otherwise stated. 1. The present system was found to be quite useful for continuous measurement of muscle rigor course. 2. Muscle contraction under the anaerobic condition at 17°C reached a peak about 2 hours after the onset of measurement and thereafter it relaxed at a slow rate. In contrast, the aerobic condition under a high humidity resulted in a strong rigor, about three times stronger than that in the anaerobic condition. 3. Ultrasonic treatment (37, 000-47, 000Hz) at 25°C for 10 minutes resulted in a moderate muscle rigor. 4. Treatment of muscle strip with 2mM EGTA at 30°C for 30 minutes led to a relaxation of the muscle. 5. The muscle from the birds killed during anesthesia with pentobarbital sodium resulted in a slow rate of rigor, whereas the birds killed one day after hypophysectomy led to a quick muscle rigor as seen in intact controls. 6. A slight muscle rigor was observed when muscle strip was placed in a refrigerator at 0°C for 18.5 hours and thereafter temperature was kept at 17°C. (author)

  3. Quantitative Method of Measuring Metastatic Activity

    Science.gov (United States)

    Morrison, Dennis R. (Inventor)

    1999-01-01

    The metastatic potential of tumors can be evaluated by the quantitative detection of urokinase and DNA. The cell sample selected for examination is analyzed for the presence of high levels of urokinase and abnormal DNA using analytical flow cytometry and digital image analysis. Other factors such as membrane associated uroldnase, increased DNA synthesis rates and certain receptors can be used in the method for detection of potentially invasive tumors.

  4. Rigorous simulation: a tool to enhance decision making

    Energy Technology Data Exchange (ETDEWEB)

    Neiva, Raquel; Larson, Mel; Baks, Arjan [KBC Advanced Technologies plc, Surrey (United Kingdom)

    2012-07-01

    The world refining industries continue to be challenged by population growth (increased demand), regional market changes and the pressure of regulatory requirements to operate a 'green' refinery. Environmental regulations are reducing the value and use of heavy fuel oils, and leading to convert more of the heavier products or even heavier crude into lighter products while meeting increasingly stringent transportation fuel specifications. As a result actions are required for establishing a sustainable advantage for future success. Rigorous simulation provides a key advantage improving the time and efficient use of capital investment and maximizing profitability. Sustainably maximizing profit through rigorous modeling is achieved through enhanced performance monitoring and improved Linear Programme (LP) model accuracy. This paper contains examples on these two items. The combination of both increases overall rates of return. As refiners consider optimizing existing assets and expanding projects, the process agreed to achieve these goals is key for a successful profit improvement. The benefit of rigorous kinetic simulation with detailed fractionation allows for optimizing existing asset utilization while focusing the capital investment in the new unit(s), and therefore optimizing the overall strategic plan and return on investment. Individual process unit's monitoring works as a mechanism for validating and optimizing the plant performance. Unit monitoring is important to rectify poor performance and increase profitability. The key to a good LP relies upon the accuracy of the data used to generate the LP sub-model data. The value of rigorous unit monitoring are that the results are heat and mass balanced consistently, and are unique for a refiners unit / refinery. With the improved match of the refinery operation, the rigorous simulation models will allow capturing more accurately the non linearity of those process units and therefore provide correct

  5. Comparison of methods for miRNA extraction from plasma and quantitative recovery of RNA from plasma and cerebrospinal fluid

    Directory of Open Access Journals (Sweden)

    Melissa A McAlexander

    2013-05-01

    Full Text Available Interest in extracellular RNA has intensified as evidence accumulates that these molecules may be useful as indicators of a wide variety of biological conditions. To establish specific extracellular RNA molecules as clinically relevant biomarkers, reproducible recovery from biological samples and reliable measurements of the isolated RNA are paramount. Towards these ends, careful and rigorous comparisons of technical procedures are needed at all steps from sample handling to RNA isolation to RNA measurement protocols. In the investigations described in this methods paper, RT-qPCR was used to examine the apparent recovery of specific endogenous miRNAs and a spiked-in synthetic RNA from blood plasma samples. RNA was isolated using several widely used RNA isolation kits, with or without the addition of glycogen as a carrier. Kits examined included total RNA isolation systems that have been commercially available for several years and commonly adapted for extraction of biofluid RNA, as well as more recently introduced biofluids-specific RNA methods. Our conclusions include the following: some RNA isolation methods appear to be superior to others for the recovery of RNA from biological fluids; addition of a carrier molecule seems to be beneficial for some but not all isolation methods; and partially or fully quantitative recovery of RNA is observed from increasing volumes of plasma and cerebrospinal fluid.

  6. RIGOR MORTIS AND THE INFLUENCE OF CALCIUM AND MAGNESIUM SALTS UPON ITS DEVELOPMENT.

    Science.gov (United States)

    Meltzer, S J; Auer, J

    1908-01-01

    Calcium salts hasten and magnesium salts retard the development of rigor mortis, that is, when these salts are administered subcutaneously or intravenously. When injected intra-arterially, concentrated solutions of both kinds of salts cause nearly an immediate onset of a strong stiffness of the muscles which is apparently a contraction, brought on by a stimulation caused by these salts and due to osmosis. This contraction, if strong, passes over without a relaxation into a real rigor. This form of rigor may be classed as work-rigor (Arbeitsstarre). In animals, at least in frogs, with intact cords, the early contraction and the following rigor are stronger than in animals with destroyed cord. If M/8 solutions-nearly equimolecular to "physiological" solutions of sodium chloride-are used, even when injected intra-arterially, calcium salts hasten and magnesium salts retard the onset of rigor. The hastening and retardation in this case as well as in the cases of subcutaneous and intravenous injections, are ion effects and essentially due to the cations, calcium and magnesium. In the rigor hastened by calcium the effects of the extensor muscles mostly prevail; in the rigor following magnesium injection, on the other hand, either the flexor muscles prevail or the muscles become stiff in the original position of the animal at death. There seems to be no difference in the degree of stiffness in the final rigor, only the onset and development of the rigor is hastened in the case of the one salt and retarded in the other. Calcium hastens also the development of heat rigor. No positive facts were obtained with regard to the effect of magnesium upon heat vigor. Calcium also hastens and magnesium retards the onset of rigor in the left ventricle of the heart. No definite data were gathered with regard to the effects of these salts upon the right ventricle.

  7. A ''new'' approach to the quantitative statistical dynamics of plasma turbulence: The optimum theory of rigorous bounds on steady-state transport

    International Nuclear Information System (INIS)

    Krommes, J.A.; Kim, Chang-Bae

    1990-06-01

    The fundamental problem in the theory of turbulent transport is to find the flux Γ of a quantity such as heat. Methods based on statistical closures are mired in conceptual controversies and practical difficulties. However, it is possible to bound Γ by employing constraints derived rigorously from the equations of motion. Brief reviews of the general theory and its application to passive advection are given. Then, a detailed application is made to anomalous resistivity generated by self-consistent turbulence in a reversed-field pinch. A nonlinear variational principle for an upper bound on the turbulence electromotive force for fixed current is formulated from the magnetohydrodynamic equations in cylindrical geometry. Numerical solution of a case constrained solely by energy balance leads to a reasonable bound and nonlinear eigenfunctions that share intriguing features with experimental data: the dominant mode numbers appear to be correct, and field reversal is predicted at reasonable values of the pinch parameter. Although open questions remain upon considering all bounding calculations to date one can conclude, remarkably, that global energy balance constrains transport sufficiently so that bounds derived therefrom are not unreasonable and that bounding calculations are feasible even for involved practical problems. The potential of the method has hardly been tapped; it provides a fertile area for future research. 29 refs

  8. A ''new'' approach to the quantitative statistical dynamics of plasma turbulence: The optimum theory of rigorous bounds on steady-state transport

    International Nuclear Information System (INIS)

    Krommes, J.A.; Kim, C.

    1990-01-01

    The fundamental problem in the theory of turbulent transport is to find the flux Γ of a quantity such as heat. Methods based on statistical closures are mired in conceptual controversies and practical difficulties. However, it is possible to bound Γ by employing constraints derived rigorously from the equations of motion. Brief reviews of the general theory and its application to passive advection are given. Then, a detailed application is made to anomalous resistivity generated by self-consistent turbulence in a reversed-field pinch. A nonlinear variational principle for an upper bound on the turbulent electromotive force for fixed current is formulated from the magnetohydrodynamic equations in cylindrical geometry. Numerical solution of a case constrained solely by energy balance leads to a reasonable bound and nonlinear eigenfunctions that share intriguing features with experimental data: The dominant mode numbers appear to be correct, and field reversal is predicted at reasonable values of the pinch parameter. Although open questions remain, upon considering all bounding calculations to date it can be concluded, remarkably, that global energy balance constrains transport sufficiently so that bounds derived therefrom are not unreasonable and that bounding calculations are feasible even for involved practical problems. The potential of the method has hardly been tapped; it provides a fertile area for future research

  9. The method of quantitative X-ray microanalysis of fine inclusions in copper

    International Nuclear Information System (INIS)

    Morawiec, H.; Kubica, L.; Piszczek, J.

    1978-01-01

    The method of correction for the matrix effect in quantitative x-ray microanalysis was presented. The application of the method was discussed on the example of quantitative analysis of fine inclusions of Cu 2 S and Cu 2 O in copper. (author)

  10. Studying learning in the healthcare setting: the potential of quantitative diary methods

    NARCIS (Netherlands)

    Ciere, Yvette; Jaarsma, Debbie; Visser, Annemieke; Sanderman, Robbert; Snippe, Evelien; Fleer, Joke

    2015-01-01

    Quantitative diary methods are longitudinal approaches that involve the repeated measurement of aspects of peoples’ experience of daily life. In this article, we outline the main characteristics and applications of quantitative diary methods and discuss how their use may further research in the

  11. Innovative Mixed-Methods Research: Moving beyond Design Technicalities to Epistemological and Methodological Realizations

    Science.gov (United States)

    Riazi, A. Mehdi

    2016-01-01

    Mixed-methods research (MMR), as an inter-discourse (quantitative and qualitative) methodology, can provide applied linguistics researchers the opportunity to draw on and integrate the strengths of the two research methodological approaches in favour of making more rigorous inferences about research problems. In this article, the argument is made…

  12. Rigorous bounds on the free energy of electron-phonon models

    NARCIS (Netherlands)

    Raedt, Hans De; Michielsen, Kristel

    1997-01-01

    We present a collection of rigorous upper and lower bounds to the free energy of electron-phonon models with linear electron-phonon interaction. These bounds are used to compare different variational approaches. It is shown rigorously that the ground states corresponding to the sharpest bounds do

  13. 1995 Quantitative Survey of the Corals of American Samoa (NODC Accession 0001972)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A survey of coral communities was carried out in the American Samoa Archipelago to assess the current status of coral reefs and provide a rigorous quantitative...

  14. Quantitative survey of the corals of American Samoa, 1995 (NODC Accession 0001972)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A survey of coral communities was carried out in the American Samoa Archipelago to assess the current status of coral reefs and provide a rigorous quantitative...

  15. Industrial ecology: Quantitative methods for exploring a lower carbon future

    Science.gov (United States)

    Thomas, Valerie M.

    2015-03-01

    Quantitative methods for environmental and cost analyses of energy, industrial, and infrastructure systems are briefly introduced and surveyed, with the aim of encouraging broader utilization and development of quantitative methods in sustainable energy research. Material and energy flow analyses can provide an overall system overview. The methods of engineering economics and cost benefit analysis, such as net present values, are the most straightforward approach for evaluating investment options, with the levelized cost of energy being a widely used metric in electricity analyses. Environmental lifecycle assessment has been extensively developed, with both detailed process-based and comprehensive input-output approaches available. Optimization methods provide an opportunity to go beyond engineering economics to develop detailed least-cost or least-impact combinations of many different choices.

  16. Intra-laboratory validation of chronic bee paralysis virus quantitation using an accredited standardised real-time quantitative RT-PCR method.

    Science.gov (United States)

    Blanchard, Philippe; Regnault, Julie; Schurr, Frank; Dubois, Eric; Ribière, Magali

    2012-03-01

    Chronic bee paralysis virus (CBPV) is responsible for chronic bee paralysis, an infectious and contagious disease in adult honey bees (Apis mellifera L.). A real-time RT-PCR assay to quantitate the CBPV load is now available. To propose this assay as a reference method, it was characterised further in an intra-laboratory study during which the reliability and the repeatability of results and the performance of the assay were confirmed. The qPCR assay alone and the whole quantitation method (from sample RNA extraction to analysis) were both assessed following the ISO/IEC 17025 standard and the recent XP U47-600 standard issued by the French Standards Institute. The performance of the qPCR assay and of the overall CBPV quantitation method were validated over a 6 log range from 10(2) to 10(8) with a detection limit of 50 and 100 CBPV RNA copies, respectively, and the protocol of the real-time RT-qPCR assay for CBPV quantitation was approved by the French Accreditation Committee. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Statistics for mathematicians a rigorous first course

    CERN Document Server

    Panaretos, Victor M

    2016-01-01

    This textbook provides a coherent introduction to the main concepts and methods of one-parameter statistical inference. Intended for students of Mathematics taking their first course in Statistics, the focus is on Statistics for Mathematicians rather than on Mathematical Statistics. The goal is not to focus on the mathematical/theoretical aspects of the subject, but rather to provide an introduction to the subject tailored to the mindset and tastes of Mathematics students, who are sometimes turned off by the informal nature of Statistics courses. This book can be used as the basis for an elementary semester-long first course on Statistics with a firm sense of direction that does not sacrifice rigor. The deeper goal of the text is to attract the attention of promising Mathematics students.

  18. A general method for bead-enhanced quantitation by flow cytometry

    Science.gov (United States)

    Montes, Martin; Jaensson, Elin A.; Orozco, Aaron F.; Lewis, Dorothy E.; Corry, David B.

    2009-01-01

    Flow cytometry provides accurate relative cellular quantitation (percent abundance) of cells from diverse samples, but technical limitations of most flow cytometers preclude accurate absolute quantitation. Several quantitation standards are now commercially available which, when added to samples, permit absolute quantitation of CD4+ T cells. However, these reagents are limited by their cost, technical complexity, requirement for additional software and/or limited applicability. Moreover, few studies have validated the use of such reagents in complex biological samples, especially for quantitation of non-T cells. Here we show that addition to samples of known quantities of polystyrene fluorescence standardization beads permits accurate quantitation of CD4+ T cells from complex cell samples. This procedure, here termed single bead-enhanced cytofluorimetry (SBEC), was equally capable of enumerating eosinophils as well as subcellular fragments of apoptotic cells, moieties with very different optical and fluorescent characteristics. Relative to other proprietary products, SBEC is simple, inexpensive and requires no special software, suggesting that the method is suitable for the routine quantitation of most cells and other particles by flow cytometry. PMID:17067632

  19. Accelerating Biomedical Discoveries through Rigor and Transparency.

    Science.gov (United States)

    Hewitt, Judith A; Brown, Liliana L; Murphy, Stephanie J; Grieder, Franziska; Silberberg, Shai D

    2017-07-01

    Difficulties in reproducing published research findings have garnered a lot of press in recent years. As a funder of biomedical research, the National Institutes of Health (NIH) has taken measures to address underlying causes of low reproducibility. Extensive deliberations resulted in a policy, released in 2015, to enhance reproducibility through rigor and transparency. We briefly explain what led to the policy, describe its elements, provide examples and resources for the biomedical research community, and discuss the potential impact of the policy on translatability with a focus on research using animal models. Importantly, while increased attention to rigor and transparency may lead to an increase in the number of laboratory animals used in the near term, it will lead to more efficient and productive use of such resources in the long run. The translational value of animal studies will be improved through more rigorous assessment of experimental variables and data, leading to better assessments of the translational potential of animal models, for the benefit of the research community and society. Published by Oxford University Press on behalf of the Institute for Laboratory Animal Research 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  20. Quantitative EDXS analysis of organic materials using the ζ-factor method

    International Nuclear Information System (INIS)

    Fladischer, Stefanie; Grogger, Werner

    2014-01-01

    In this study we successfully applied the ζ-factor method to perform quantitative X-ray analysis of organic thin films consisting of light elements. With its ability to intrinsically correct for X-ray absorption, this method significantly improved the quality of the quantification as well as the accuracy of the results compared to conventional techniques in particular regarding the quantification of light elements. We describe in detail the process of determining sensitivity factors (ζ-factors) using a single standard specimen and the involved parameter optimization for the estimation of ζ-factors for elements not contained in the standard. The ζ-factor method was then applied to perform quantitative analysis of organic semiconducting materials frequently used in organic electronics. Finally, the results were verified and discussed concerning validity and accuracy. - Highlights: • The ζ-factor method is used for quantitative EDXS analysis of light elements. • We describe the process of determining ζ-factors from a single standard in detail. • Organic semiconducting materials are successfully quantified

  1. Application of quantitative and qualitative methods for determination ...

    African Journals Online (AJOL)

    This article covers the issues of integration of qualitative and quantitative methods applied when justifying management decision-making in companies implementing lean manufacturing. The authors defined goals and subgoals and justified the evaluation criteria which lead to the increased company value if achieved.

  2. Quantitative evaluation methods of skin condition based on texture feature parameters

    Directory of Open Access Journals (Sweden)

    Hui Pang

    2017-03-01

    Full Text Available In order to quantitatively evaluate the improvement of the skin condition after using skin care products and beauty, a quantitative evaluation method for skin surface state and texture is presented, which is convenient, fast and non-destructive. Human skin images were collected by image sensors. Firstly, the median filter of the 3 × 3 window is used and then the location of the hairy pixels on the skin is accurately detected according to the gray mean value and color information. The bilinear interpolation is used to modify the gray value of the hairy pixels in order to eliminate the negative effect of noise and tiny hairs on the texture. After the above pretreatment, the gray level co-occurrence matrix (GLCM is calculated. On the basis of this, the four characteristic parameters, including the second moment, contrast, entropy and correlation, and their mean value are calculated at 45 ° intervals. The quantitative evaluation model of skin texture based on GLCM is established, which can calculate the comprehensive parameters of skin condition. Experiments show that using this method evaluates the skin condition, both based on biochemical indicators of skin evaluation methods in line, but also fully consistent with the human visual experience. This method overcomes the shortcomings of the biochemical evaluation method of skin damage and long waiting time, also the subjectivity and fuzziness of the visual evaluation, which achieves the non-destructive, rapid and quantitative evaluation of skin condition. It can be used for health assessment or classification of the skin condition, also can quantitatively evaluate the subtle improvement of skin condition after using skin care products or stage beauty.

  3. Quantitative evaluation methods of skin condition based on texture feature parameters.

    Science.gov (United States)

    Pang, Hui; Chen, Tianhua; Wang, Xiaoyi; Chang, Zhineng; Shao, Siqi; Zhao, Jing

    2017-03-01

    In order to quantitatively evaluate the improvement of the skin condition after using skin care products and beauty, a quantitative evaluation method for skin surface state and texture is presented, which is convenient, fast and non-destructive. Human skin images were collected by image sensors. Firstly, the median filter of the 3 × 3 window is used and then the location of the hairy pixels on the skin is accurately detected according to the gray mean value and color information. The bilinear interpolation is used to modify the gray value of the hairy pixels in order to eliminate the negative effect of noise and tiny hairs on the texture. After the above pretreatment, the gray level co-occurrence matrix (GLCM) is calculated. On the basis of this, the four characteristic parameters, including the second moment, contrast, entropy and correlation, and their mean value are calculated at 45 ° intervals. The quantitative evaluation model of skin texture based on GLCM is established, which can calculate the comprehensive parameters of skin condition. Experiments show that using this method evaluates the skin condition, both based on biochemical indicators of skin evaluation methods in line, but also fully consistent with the human visual experience. This method overcomes the shortcomings of the biochemical evaluation method of skin damage and long waiting time, also the subjectivity and fuzziness of the visual evaluation, which achieves the non-destructive, rapid and quantitative evaluation of skin condition. It can be used for health assessment or classification of the skin condition, also can quantitatively evaluate the subtle improvement of skin condition after using skin care products or stage beauty.

  4. Trends: Rigor Mortis in the Arts.

    Science.gov (United States)

    Blodget, Alden S.

    1991-01-01

    Outlines how past art education provided a refuge for students from the rigors of other academic subjects. Observes that in recent years art education has become "discipline based." Argues that art educators need to reaffirm their commitment to a humanistic way of knowing. (KM)

  5. A quantitative method for evaluating alternatives. [aid to decision making

    Science.gov (United States)

    Forthofer, M. J.

    1981-01-01

    When faced with choosing between alternatives, people tend to use a number of criteria (often subjective, rather than objective) to decide which is the best alternative for them given their unique situation. The subjectivity inherent in the decision-making process can be reduced by the definition and use of a quantitative method for evaluating alternatives. This type of method can help decision makers achieve degree of uniformity and completeness in the evaluation process, as well as an increased sensitivity to the factors involved. Additional side-effects are better documentation and visibility of the rationale behind the resulting decisions. General guidelines for defining a quantitative method are presented and a particular method (called 'hierarchical weighted average') is defined and applied to the evaluation of design alternatives for a hypothetical computer system capability.

  6. Re-establishment of rigor mortis: evidence for a considerably longer post-mortem time span.

    Science.gov (United States)

    Crostack, Chiara; Sehner, Susanne; Raupach, Tobias; Anders, Sven

    2017-07-01

    Re-establishment of rigor mortis following mechanical loosening is used as part of the complex method for the forensic estimation of the time since death in human bodies and has formerly been reported to occur up to 8-12 h post-mortem (hpm). We recently described our observation of the phenomenon in up to 19 hpm in cases with in-hospital death. Due to the case selection (preceding illness, immobilisation), transfer of these results to forensic cases might be limited. We therefore examined 67 out-of-hospital cases of sudden death with known time points of death. Re-establishment of rigor mortis was positive in 52.2% of cases and was observed up to 20 hpm. In contrast to the current doctrine that a recurrence of rigor mortis is always of a lesser degree than its first manifestation in a given patient, muscular rigidity at re-establishment equalled or even exceeded the degree observed before dissolving in 21 joints. Furthermore, this is the first study to describe that the phenomenon appears to be independent of body or ambient temperature.

  7. A Methodology for Conducting Integrative Mixed Methods Research and Data Analyses

    Science.gov (United States)

    Castro, Felipe González; Kellison, Joshua G.; Boyd, Stephen J.; Kopak, Albert

    2011-01-01

    Mixed methods research has gained visibility within the last few years, although limitations persist regarding the scientific caliber of certain mixed methods research designs and methods. The need exists for rigorous mixed methods designs that integrate various data analytic procedures for a seamless transfer of evidence across qualitative and quantitative modalities. Such designs can offer the strength of confirmatory results drawn from quantitative multivariate analyses, along with “deep structure” explanatory descriptions as drawn from qualitative analyses. This article presents evidence generated from over a decade of pilot research in developing an integrative mixed methods methodology. It presents a conceptual framework and methodological and data analytic procedures for conducting mixed methods research studies, and it also presents illustrative examples from the authors' ongoing integrative mixed methods research studies. PMID:22167325

  8. Shaping Social Work Science: What Should Quantitative Researchers Do?

    Science.gov (United States)

    Guo, Shenyang

    2015-01-01

    Based on a review of economists' debates on mathematical economics, this article discusses a key issue for shaping the science of social work--research methodology. The article describes three important tasks quantitative researchers need to fulfill in order to enhance the scientific rigor of social work research. First, to test theories using…

  9. Methodological Challenges in Sustainability Science: A Call for Method Plurality, Procedural Rigor and Longitudinal Research

    Directory of Open Access Journals (Sweden)

    Henrik von Wehrden

    2017-02-01

    Full Text Available Sustainability science encompasses a unique field that is defined through its purpose, the problem it addresses, and its solution-oriented agenda. However, this orientation creates significant methodological challenges. In this discussion paper, we conceptualize sustainability problems as wicked problems to tease out the key challenges that sustainability science is facing if scientists intend to deliver on its solution-oriented agenda. Building on the available literature, we discuss three aspects that demand increased attention for advancing sustainability science: 1 methods with higher diversity and complementarity are needed to increase the chance of deriving solutions to the unique aspects of wicked problems; for instance, mixed methods approaches are potentially better suited to allow for an approximation of solutions, since they cover wider arrays of knowledge; 2 methodologies capable of dealing with wicked problems demand strict procedural and ethical guidelines, in order to ensure their integration potential; for example, learning from solution implementation in different contexts requires increased comparability between research approaches while carefully addressing issues of legitimacy and credibility; and 3 approaches are needed that allow for longitudinal research, since wicked problems are continuous and solutions can only be diagnosed in retrospect; for example, complex dynamics of wicked problems play out across temporal patterns that are not necessarily aligned with the common timeframe of participatory sustainability research. Taken together, we call for plurality in methodologies, emphasizing procedural rigor and the necessity of continuous research to effectively addressing wicked problems as well as methodological challenges in sustainability science.

  10. Can qualitative and quantitative methods serve complementary purposes for policy research?

    OpenAIRE

    Maxwell, Daniel G.

    1998-01-01

    Qualitative and quantitative methods in social science research have long been separate spheres with little overlap. However, recent innovations have highlighted the complementarity of qualitative and quantitative approaches. The Accra Food and Nutrition Security Study was designed to incorporate the participation of a variety of constituencies in the research, and to rely on a variety of approaches — both qualitative and quantitative — to data collection and analysis. This paper reviews the ...

  11. Quantitative angiography methods for bifurcation lesions

    DEFF Research Database (Denmark)

    Collet, Carlos; Onuma, Yoshinobu; Cavalcante, Rafael

    2017-01-01

    Bifurcation lesions represent one of the most challenging lesion subsets in interventional cardiology. The European Bifurcation Club (EBC) is an academic consortium whose goal has been to assess and recommend the appropriate strategies to manage bifurcation lesions. The quantitative coronary...... angiography (QCA) methods for the evaluation of bifurcation lesions have been subject to extensive research. Single-vessel QCA has been shown to be inaccurate for the assessment of bifurcation lesion dimensions. For this reason, dedicated bifurcation software has been developed and validated. These software...

  12. Instrumentation and quantitative methods of evaluation. Progress report, January 15-September 14, 1986

    International Nuclear Information System (INIS)

    Beck, R.N.

    1986-09-01

    This document reports progress under grant entitled ''Instrumentation and Quantitative Methods of Evaluation.'' Individual reports are presented on projects entitled the physical aspects of radionuclide imaging, image reconstruction and quantitative evaluation, PET-related instrumentation for improved quantitation, improvements in the FMI cyclotron for increased utilization, and methodology for quantitative evaluation of diagnostic performance

  13. Novel approach in quantitative analysis of shearography method

    International Nuclear Information System (INIS)

    Wan Saffiey Wan Abdullah

    2002-01-01

    The application of laser interferometry in industrial non-destructive testing and material characterization is becoming more prevalent since this method provides non-contact full-field inspection of the test object. However their application only limited to the qualitative analysis, current trend has changed to the development of this method by the introduction of quantitative analysis, which attempts to detail the defect examined. This being the design feature for a ranges of object size to be examined. The growing commercial demand for quantitative analysis for NDT and material characterization is determining the quality of optical and analysis instrument. However very little attention is currently being paid to understanding, quantifying and compensating for the numerous error sources which are a function of interferometers. This paper presents a comparison of measurement analysis using the established theoretical approach and the new approach, taken into account the factor of divergence illumination and other geometrical factors. The difference in the measurement system could be associated in the error factor. (Author)

  14. Direct integration of the S-matrix applied to rigorous diffraction

    International Nuclear Information System (INIS)

    Iff, W; Lindlein, N; Tishchenko, A V

    2014-01-01

    A novel Fourier method for rigorous diffraction computation at periodic structures is presented. The procedure is based on a differential equation for the S-matrix, which allows direct integration of the S-matrix blocks. This results in a new method in Fourier space, which can be considered as a numerically stable and well-parallelizable alternative to the conventional differential method based on T-matrix integration and subsequent conversions from the T-matrices to S-matrix blocks. Integration of the novel differential equation in implicit manner is expounded. The applicability of the new method is shown on the basis of 1D periodic structures. It is clear however, that the new technique can also be applied to arbitrary 2D periodic or periodized structures. The complexity of the new method is O(N 3 ) similar to the conventional differential method with N being the number of diffraction orders. (fast track communication)

  15. Quantitative phosphoproteomic analysis of postmortem muscle development

    DEFF Research Database (Denmark)

    Huang, Honggang

    Meat quality development is highly dependent on postmortem (PM) metabolism and rigor mortis development in PM muscle. PM glycometabolism and rigor mortis fundamentally determine most of the important qualities of raw meat, such as ultimate pH, tenderness, color and water-holding capacity. Protein...... phosphorylation is known to play essential roles on regulating metabolism, contraction and other important activities in muscle systems. However, protein phosphorylation has rarely been systematically explored in PM muscle in relation to meat quality. In this PhD project, both gel-based and mass spectrometry (MS......)-based quantitative phosphoproteomic strategies were employed to analyze PM muscle with the aim to intensively characterize the protein phosphorylation involved in meat quality development. Firstly, gel-based phosphoproteomic studies were performed to analyze the protein phosphorylation in both sarcoplasmic proteins...

  16. Quantitative methods for the analysis of electron microscope images

    DEFF Research Database (Denmark)

    Skands, Peter Ulrik Vallø

    1996-01-01

    The topic of this thesis is an general introduction to quantitative methods for the analysis of digital microscope images. The images presented are primarily been acquired from Scanning Electron Microscopes (SEM) and interfermeter microscopes (IFM). The topic is approached though several examples...... foundation of the thesis fall in the areas of: 1) Mathematical Morphology; 2) Distance transforms and applications; and 3) Fractal geometry. Image analysis opens in general the possibility of a quantitative and statistical well founded measurement of digital microscope images. Herein lies also the conditions...

  17. Phase analysis in duplex stainless steel: comparison of EBSD and quantitative metallography methods

    International Nuclear Information System (INIS)

    Michalska, J; Chmiela, B

    2014-01-01

    The purpose of the research was to work out the qualitative and quantitative analysis of phases in DSS in as-received state and after thermal aging. For quantitative purposes, SEM observations, EDS analyses and electron backscattered diffraction (EBSD) methods were employed. Qualitative analysis of phases was performed by two methods: EBSD and classical quantitative metallography. A juxtaposition of different etchants for the revealing of microstructure and brief review of sample preparation methods for EBSD studies were presented. Different ways of sample preparation were tested and based on these results a detailed methodology of DSS phase analysis was developed including: surface finishing, selective etching methods and image acquisition. The advantages and disadvantages of applied methods were pointed out and compared the accuracy of the analysis phase performed by both methods

  18. How Individual Scholars Can Reduce the Rigor-Relevance Gap in Management Research

    OpenAIRE

    Wolf, Joachim; Rosenberg, Timo

    2012-01-01

    This paper discusses a number of avenues management scholars could follow to reduce the existing gap between scientific rigor and practical relevance without relativizing the importance of the first goal dimension. Such changes are necessary because many management studies do not fully exploit the possibilities to increase their practical relevance while maintaining scientific rigor. We argue that this rigor-relevance gap is not only the consequence of the currently prevailing institutional c...

  19. Onset of rigor mortis is earlier in red muscle than in white muscle.

    Science.gov (United States)

    Kobayashi, M; Takatori, T; Nakajima, M; Sakurada, K; Hatanaka, K; Ikegaya, H; Matsuda, Y; Iwase, H

    2000-01-01

    Rigor mortis is thought to be related to falling ATP levels in muscles postmortem. We measured rigor mortis as tension determined isometrically in three rat leg muscles in liquid paraffin kept at 37 degrees C or 25 degrees C--two red muscles, red gastrocnemius (RG) and soleus (SO) and one white muscle, white gastrocnemius (WG). Onset, half and full rigor mortis occurred earlier in RG and SO than in WG both at 37 degrees C and at 25 degrees C even though RG and WG were portions of the same muscle. This suggests that rigor mortis directly reflects the postmortem intramuscular ATP level, which decreases more rapidly in red muscle than in white muscle after death. Rigor mortis was more retarded at 25 degrees C than at 37 degrees C in each type of muscle.

  20. Evaluation of physical dimension changes as nondestructive measurements for monitoring rigor mortis development in broiler muscles.

    Science.gov (United States)

    Cavitt, L C; Sams, A R

    2003-07-01

    Studies were conducted to develop a non-destructive method for monitoring the rate of rigor mortis development in poultry and to evaluate the effectiveness of electrical stimulation (ES). In the first study, 36 male broilers in each of two trials were processed at 7 wk of age. After being bled, half of the birds received electrical stimulation (400 to 450 V, 400 to 450 mA, for seven pulses of 2 s on and 1 s off), and the other half were designated as controls. At 0.25 and 1.5 h postmortem (PM), carcasses were evaluated for the angles of the shoulder, elbow, and wing tip and the distance between the elbows. Breast fillets were harvested at 1.5 h PM (after chilling) from all carcasses. Fillet samples were excised and frozen for later measurement of pH and R-value, and the remainder of each fillet was held on ice until 24 h postmortem. Shear value and pH means were significantly lower, but R-value means were higher (P rigor mortis by ES. The physical dimensions of the shoulder and elbow changed (P rigor mortis development and with ES. These results indicate that physical measurements of the wings maybe useful as a nondestructive indicator of rigor development and for monitoring the effectiveness of ES. In the second study, 60 male broilers in each of two trials were processed at 7 wk of age. At 0.25, 1.5, 3.0, and 6.0 h PM, carcasses were evaluated for the distance between the elbows. At each time point, breast fillets were harvested from each carcass. Fillet samples were excised and frozen for later measurement of pH and sacromere length, whereas the remainder of each fillet was held on ice until 24 h PM. Shear value and pH means (P rigor mortis development. Elbow distance decreased (P rigor development and was correlated (P rigor mortis development in broiler carcasses.

  1. A rigorous phenomenological analysis of the ππ scattering lengths

    International Nuclear Information System (INIS)

    Caprini, I.; Dita, P.; Sararu, M.

    1979-11-01

    The constraining power of the present experimental data, combined with the general theoretical knowledge about ππ scattering, upon the scattering lengths of this process, is investigated by means of a rigorous functional method. We take as input the experimental phase shifts and make no hypotheses about the high energy behaviour of the amplitudes, using only absolute bounds derived from axiomatic field theory and exact consequences of crossing symmetry. In the simplest application of the method, involving only the π 0 π 0 S-wave, we explored numerically a number of values proposed by various authors for the scattering lengths a 0 and a 2 and found that no one appears to be especially favoured. (author)

  2. A methodology for the rigorous verification of plasma simulation codes

    Science.gov (United States)

    Riva, Fabio

    2016-10-01

    The methodology used to assess the reliability of numerical simulation codes constitutes the Verification and Validation (V&V) procedure. V&V is composed by two separate tasks: the verification, which is a mathematical issue targeted to assess that the physical model is correctly solved, and the validation, which determines the consistency of the code results, and therefore of the physical model, with experimental data. In the present talk we focus our attention on the verification, which in turn is composed by the code verification, targeted to assess that a physical model is correctly implemented in a simulation code, and the solution verification, that quantifies the numerical error affecting a simulation. Bridging the gap between plasma physics and other scientific domains, we introduced for the first time in our domain a rigorous methodology for the code verification, based on the method of manufactured solutions, as well as a solution verification based on the Richardson extrapolation. This methodology was applied to GBS, a three-dimensional fluid code based on a finite difference scheme, used to investigate the plasma turbulence in basic plasma physics experiments and in the tokamak scrape-off layer. Overcoming the difficulty of dealing with a numerical method intrinsically affected by statistical noise, we have now generalized the rigorous verification methodology to simulation codes based on the particle-in-cell algorithm, which are employed to solve Vlasov equation in the investigation of a number of plasma physics phenomena.

  3. Photoconductivity of amorphous silicon-rigorous modelling

    International Nuclear Information System (INIS)

    Brada, P.; Schauer, F.

    1991-01-01

    It is our great pleasure to express our gratitude to Prof. Grigorovici, the pioneer of the exciting field of amorphous state by our modest contribution to this area. In this paper are presented the outline of the rigorous modelling program of the steady-state photoconductivity in amorphous silicon and related materials. (Author)

  4. Embedding Quantitative Methods by Stealth in Political Science: Developing a Pedagogy for Psephology

    Science.gov (United States)

    Gunn, Andrew

    2017-01-01

    Student evaluations of quantitative methods courses in political science often reveal they are characterised by aversion, alienation and anxiety. As a solution to this problem, this paper describes a pedagogic research project with the aim of embedding quantitative methods by stealth into the first-year undergraduate curriculum. This paper…

  5. Vibrational algorithms for quantitative crystallographic analyses of hydroxyapatite-based biomaterials: II, application to decayed human teeth.

    Science.gov (United States)

    Adachi, Tetsuya; Pezzotti, Giuseppe; Yamamoto, Toshiro; Ichioka, Hiroaki; Boffelli, Marco; Zhu, Wenliang; Kanamura, Narisato

    2015-05-01

    A systematic investigation, based on highly spectrally resolved Raman spectroscopy, was undertaken to research the efficacy of vibrational assessments in locating chemical and crystallographic fingerprints for the characterization of dental caries and the early detection of non-cavitated carious lesions. Raman results published by other authors have indicated possible approaches for this method. However, they conspicuously lacked physical insight at the molecular scale and, thus, the rigor necessary to prove the efficacy of this spectroscopy method. After solving basic physical challenges in a companion paper, we apply them here in the form of newly developed Raman algorithms for practical dental research. Relevant differences in mineral crystallite (average) orientation and texture distribution were revealed for diseased enamel at different stages compared with healthy mineralized enamel. Clear spectroscopy features could be directly translated in terms of a rigorous and quantitative classification of crystallography and chemical characteristics of diseased enamel structures. The Raman procedure enabled us to trace back otherwise invisible characteristics in early caries, in the translucent zone (i.e., the advancing front of the disease) and in the body of lesion of cavitated caries.

  6. Simple PVT quantitative method of Kr under high pure N2 condition

    International Nuclear Information System (INIS)

    Li Xuesong; Zhang Zibin; Wei Guanyi; Chen Liyun; Zhai Lihua

    2005-01-01

    A simple PVT quantitative method of Kr in the high pure N 2 was studied. Pressure, volume and temperature of the sample gas were measured by three individual methods to obtain the sum sample with food uncertainty. The ratio of Kr/N 2 could measured by GAM 400 quadrupole mass spectrometer. So the quantity of Kr could be calculated with the two measured data above. This method can be suited for quantitative analysis of other simple composed noble gas sample with high pure carrying gas. (authors)

  7. Increasing Literacy in Quantitative Methods: The Key to the Future of Canadian Psychology

    Science.gov (United States)

    Counsell, Alyssa; Cribbie, Robert A.; Harlow, Lisa. L.

    2016-01-01

    Quantitative methods (QM) dominate empirical research in psychology. Unfortunately most researchers in psychology receive inadequate training in QM. This creates a challenge for researchers who require advanced statistical methods to appropriately analyze their data. Many of the recent concerns about research quality, replicability, and reporting practices are directly tied to the problematic use of QM. As such, improving quantitative literacy in psychology is an important step towards eliminating these concerns. The current paper will include two main sections that discuss quantitative challenges and opportunities. The first section discusses training and resources for students and presents descriptive results on the number of quantitative courses required and available to graduate students in Canadian psychology departments. In the second section, we discuss ways of improving quantitative literacy for faculty, researchers, and clinicians. This includes a strong focus on the importance of collaboration. The paper concludes with practical recommendations for improving quantitative skills and literacy for students and researchers in Canada. PMID:28042199

  8. Increasing Literacy in Quantitative Methods: The Key to the Future of Canadian Psychology.

    Science.gov (United States)

    Counsell, Alyssa; Cribbie, Robert A; Harlow, Lisa L

    2016-08-01

    Quantitative methods (QM) dominate empirical research in psychology. Unfortunately most researchers in psychology receive inadequate training in QM. This creates a challenge for researchers who require advanced statistical methods to appropriately analyze their data. Many of the recent concerns about research quality, replicability, and reporting practices are directly tied to the problematic use of QM. As such, improving quantitative literacy in psychology is an important step towards eliminating these concerns. The current paper will include two main sections that discuss quantitative challenges and opportunities. The first section discusses training and resources for students and presents descriptive results on the number of quantitative courses required and available to graduate students in Canadian psychology departments. In the second section, we discuss ways of improving quantitative literacy for faculty, researchers, and clinicians. This includes a strong focus on the importance of collaboration. The paper concludes with practical recommendations for improving quantitative skills and literacy for students and researchers in Canada.

  9. Reframing Rigor: A Modern Look at Challenge and Support in Higher Education

    Science.gov (United States)

    Campbell, Corbin M.; Dortch, Deniece; Burt, Brian A.

    2018-01-01

    This chapter describes the limitations of the traditional notions of academic rigor in higher education, and brings forth a new form of rigor that has the potential to support student success and equity.

  10. Comparison of conventional, model-based quantitative planar, and quantitative SPECT image processing methods for organ activity estimation using In-111 agents

    International Nuclear Information System (INIS)

    He, Bin; Frey, Eric C

    2006-01-01

    Accurate quantification of organ radionuclide uptake is important for patient-specific dosimetry. The quantitative accuracy from conventional conjugate view methods is limited by overlap of projections from different organs and background activity, and attenuation and scatter. In this work, we propose and validate a quantitative planar (QPlanar) processing method based on maximum likelihood (ML) estimation of organ activities using 3D organ VOIs and a projector that models the image degrading effects. Both a physical phantom experiment and Monte Carlo simulation (MCS) studies were used to evaluate the new method. In these studies, the accuracies and precisions of organ activity estimates for the QPlanar method were compared with those from conventional planar (CPlanar) processing methods with various corrections for scatter, attenuation and organ overlap, and a quantitative SPECT (QSPECT) processing method. Experimental planar and SPECT projections and registered CT data from an RSD Torso phantom were obtained using a GE Millenium VH/Hawkeye system. The MCS data were obtained from the 3D NCAT phantom with organ activity distributions that modelled the uptake of 111 In ibritumomab tiuxetan. The simulations were performed using parameters appropriate for the same system used in the RSD torso phantom experiment. The organ activity estimates obtained from the CPlanar, QPlanar and QSPECT methods from both experiments were compared. From the results of the MCS experiment, even with ideal organ overlap correction and background subtraction, CPlanar methods provided limited quantitative accuracy. The QPlanar method with accurate modelling of the physical factors increased the quantitative accuracy at the cost of requiring estimates of the organ VOIs in 3D. The accuracy of QPlanar approached that of QSPECT, but required much less acquisition and computation time. Similar results were obtained from the physical phantom experiment. We conclude that the QPlanar method, based

  11. QUALITATIVE AND QUANTITATIVE METHODS OF SUICIDE RESEARCH IN OLD AGE

    OpenAIRE

    Ojagbemi, A.

    2017-01-01

    This paper examines the merits of the qualitative and quantitative methods of suicide research in the elderly using two studies identified through a free search of the Pubmed database for articles that might have direct bearing on suicidality in the elderly. The studies have been purposively selected for critical appraisal because they meaningfully reflect the quantitative and qualitative divide as well as the social, economic, and cultural boundaries between the elderly living in sub-Saharan...

  12. [Reconsidering evaluation criteria regarding health care research: toward an integrative framework of quantitative and qualitative criteria].

    Science.gov (United States)

    Miyata, Hiroaki; Kai, Ichiro

    2006-05-01

    Debate about the relationship between quantitative and qualitative paradigms is often muddled and confused and the clutter of terms and arguments has resulted in the concepts becoming obscure and unrecognizable. It is therefore very important to reconsider evaluation criteria regarding rigor in social science. As Lincoln & Guba have already compared quantitative paradigms (validity, reliability, neutrality, generalizability) with qualitative paradigms (credibility, dependability, confirmability, transferability), we have discuss use of evaluation criteria based on pragmatic perspective. Validity/Credibility is the paradigm concerned to observational framework, while Reliability/Dependability refer to the range of stability in observations, Neutrality/Confirmability reflect influences between observers and subjects, Generalizability/Transferability have epistemological difference in the way findings are applied. Qualitative studies, however, does not always chose the qualitative paradigms. If we assume the stability to some extent, it is better to use the quantitative paradigm (reliability). Moreover as a quantitative study can not always guarantee a perfect observational framework, with stability in all phases of observations, it is useful to use qualitative paradigms to enhance the rigor in the study.

  13. Risk prediction, safety analysis and quantitative probability methods - a caveat

    International Nuclear Information System (INIS)

    Critchley, O.H.

    1976-01-01

    Views are expressed on the use of quantitative techniques for the determination of value judgements in nuclear safety assessments, hazard evaluation, and risk prediction. Caution is urged when attempts are made to quantify value judgements in the field of nuclear safety. Criteria are given the meaningful application of reliability methods but doubts are expressed about their application to safety analysis, risk prediction and design guidances for experimental or prototype plant. Doubts are also expressed about some concomitant methods of population dose evaluation. The complexities of new designs of nuclear power plants make the problem of safety assessment more difficult but some possible approaches are suggested as alternatives to the quantitative techniques criticized. (U.K.)

  14. Rigorous Multicomponent Reactive Separations Modelling: Complete Consideration of Reaction-Diffusion Phenomena

    International Nuclear Information System (INIS)

    Ahmadi, A.; Meyer, M.; Rouzineau, D.; Prevost, M.; Alix, P.; Laloue, N.

    2010-01-01

    This paper gives the first step of the development of a rigorous multicomponent reactive separation model. Such a model is highly essential to further the optimization of acid gases removal plants (CO 2 capture, gas treating, etc.) in terms of size and energy consumption, since chemical solvents are conventionally used. Firstly, two main modelling approaches are presented: the equilibrium-based and the rate-based approaches. Secondly, an extended rate-based model with rigorous modelling methodology for diffusion-reaction phenomena is proposed. The film theory and the generalized Maxwell-Stefan equations are used in order to characterize multicomponent interactions. The complete chain of chemical reactions is taken into account. The reactions can be kinetically controlled or at chemical equilibrium, and they are considered for both liquid film and liquid bulk. Thirdly, the method of numerical resolution is described. Coupling the generalized Maxwell-Stefan equations with chemical equilibrium equations leads to a highly non-linear Differential-Algebraic Equations system known as DAE index 3. The set of equations is discretized with finite-differences as its integration by Gear method is complex. The resulting algebraic system is resolved by the Newton- Raphson method. Finally, the present model and the associated methods of numerical resolution are validated for the example of esterification of methanol. This archetype non-electrolytic system permits an interesting analysis of reaction impact on mass transfer, especially near the phase interface. The numerical resolution of the model by Newton-Raphson method gives good results in terms of calculation time and convergence. The simulations show that the impact of reactions at chemical equilibrium and that of kinetically controlled reactions with high kinetics on mass transfer is relatively similar. Moreover, the Fick's law is less adapted for multicomponent mixtures where some abnormalities such as counter

  15. Quantitative methods for management and economics

    CERN Document Server

    Chakravarty, Pulak

    2009-01-01

    ""Quantitative Methods for Management and Economics"" is specially prepared for the MBA students in India and all over the world. It starts from the basics, such that even a beginner with out much mathematical sophistication can grasp the ideas and then comes forward to more complex and professional problems. Thus, both the ordinary students as well as ""above average: i.e., ""bright and sincere"" students would be benefited equally through this book.Since, most of the problems are solved or hints are given, students can do well within the short duration of the semesters of their busy course.

  16. Study of the quantitative analysis approach of maintenance by the Monte Carlo simulation method

    International Nuclear Information System (INIS)

    Shimizu, Takashi

    2007-01-01

    This study is examination of the quantitative valuation by Monte Carlo simulation method of maintenance activities of a nuclear power plant. Therefore, the concept of the quantitative valuation of maintenance that examination was advanced in the Japan Society of Maintenology and International Institute of Universality (IUU) was arranged. Basis examination for quantitative valuation of maintenance was carried out at simple feed water system, by Monte Carlo simulation method. (author)

  17. Memory sparing, fast scattering formalism for rigorous diffraction modeling

    Science.gov (United States)

    Iff, W.; Kämpfe, T.; Jourlin, Y.; Tishchenko, A. V.

    2017-07-01

    The basics and algorithmic steps of a novel scattering formalism suited for memory sparing and fast electromagnetic calculations are presented. The formalism, called ‘S-vector algorithm’ (by analogy with the known scattering-matrix algorithm), allows the calculation of the collective scattering spectra of individual layered micro-structured scattering objects. A rigorous method of linear complexity is applied to model the scattering at individual layers; here the generalized source method (GSM) resorting to Fourier harmonics as basis functions is used as one possible method of linear complexity. The concatenation of the individual scattering events can be achieved sequentially or in parallel, both having pros and cons. The present development will largely concentrate on a consecutive approach based on the multiple reflection series. The latter will be reformulated into an implicit formalism which will be associated with an iterative solver, resulting in improved convergence. The examples will first refer to 1D grating diffraction for the sake of simplicity and intelligibility, with a final 2D application example.

  18. Single-case synthesis tools I: Comparing tools to evaluate SCD quality and rigor.

    Science.gov (United States)

    Zimmerman, Kathleen N; Ledford, Jennifer R; Severini, Katherine E; Pustejovsky, James E; Barton, Erin E; Lloyd, Blair P

    2018-03-03

    Tools for evaluating the quality and rigor of single case research designs (SCD) are often used when conducting SCD syntheses. Preferred components include evaluations of design features related to the internal validity of SCD to obtain quality and/or rigor ratings. Three tools for evaluating the quality and rigor of SCD (Council for Exceptional Children, What Works Clearinghouse, and Single-Case Analysis and Design Framework) were compared to determine if conclusions regarding the effectiveness of antecedent sensory-based interventions for young children changed based on choice of quality evaluation tool. Evaluation of SCD quality differed across tools, suggesting selection of quality evaluation tools impacts evaluation findings. Suggestions for selecting an appropriate quality and rigor assessment tool are provided and across-tool conclusions are drawn regarding the quality and rigor of studies. Finally, authors provide guidance for using quality evaluations in conjunction with outcome analyses when conducting syntheses of interventions evaluated in the context of SCD. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Quantitative analysis of iodine in thyroidin. I. Methods of ''dry'' and ''wet'' mineralization

    International Nuclear Information System (INIS)

    Listov, S.A.; Arzamastsev, A.P.

    1986-01-01

    The relative investigations on the quantitative determination of iodine in thyroidin using different modifications of the ''dry'' and ''wet'' mineralization show that in using these methods the difficulties due to the characteristic features of the object of investigation itself and the mineralization method as a whole must be taken into account. The studies show that the most applicable method for the analysis of thyroidin is the method of ''dry'' mineralization with potassium carbonate. A procedure is proposed for a quantitative determination of iodine in thyroidin

  20. Using mixed methods effectively in prevention science: designs, procedures, and examples.

    Science.gov (United States)

    Zhang, Wanqing; Watanabe-Galloway, Shinobu

    2014-10-01

    There is growing interest in using a combination of quantitative and qualitative methods to generate evidence about the effectiveness of health prevention, services, and intervention programs. With the emerging importance of mixed methods research across the social and health sciences, there has been an increased recognition of the value of using mixed methods for addressing research questions in different disciplines. We illustrate the mixed methods approach in prevention research, showing design procedures used in several published research articles. In this paper, we focused on two commonly used mixed methods designs: concurrent and sequential mixed methods designs. We discuss the types of mixed methods designs, the reasons for, and advantages of using a particular type of design, and the procedures of qualitative and quantitative data collection and integration. The studies reviewed in this paper show that the essence of qualitative research is to explore complex dynamic phenomena in prevention science, and the advantage of using mixed methods is that quantitative data can yield generalizable results and qualitative data can provide extensive insights. However, the emphasis of methodological rigor in a mixed methods application also requires considerable expertise in both qualitative and quantitative methods. Besides the necessary skills and effective interdisciplinary collaboration, this combined approach also requires an open-mindedness and reflection from the involved researchers.

  1. An unconventional method of quantitative microstructural analysis

    International Nuclear Information System (INIS)

    Rastani, M.

    1995-01-01

    The experiment described here introduces a simple methodology which could be used to replace the time-consuming and expensive conventional methods of metallographic and quantitative analysis of thermal treatment effect on microstructure. The method is ideal for the microstructural evaluation of tungsten filaments and other wire samples such as copper wire which can be conveniently coiled. Ten such samples were heat treated by ohmic resistance at temperatures which were expected to span the recrystallization range. After treatment, the samples were evaluated in the elastic recovery test. The normalized elastic recovery factor was defined in terms of these deflections. Experimentally it has shown that elastic recovery factor depends on the degree of recrystallization. In other words this factor is used to determine the fraction of unrecrystallized material. Because the elastic recovery method examines the whole filament rather than just one section through the filament as in metallographical method, it more accurately measures the degree of recrystallization. The method also takes a considerably shorter time and cost compared to the conventional method

  2. Quantitative methods for analysing cumulative effects on fish migration success: a review.

    Science.gov (United States)

    Johnson, J E; Patterson, D A; Martins, E G; Cooke, S J; Hinch, S G

    2012-07-01

    It is often recognized, but seldom addressed, that a quantitative assessment of the cumulative effects, both additive and non-additive, of multiple stressors on fish survival would provide a more realistic representation of the factors that influence fish migration. This review presents a compilation of analytical methods applied to a well-studied fish migration, a more general review of quantitative multivariable methods, and a synthesis on how to apply new analytical techniques in fish migration studies. A compilation of adult migration papers from Fraser River sockeye salmon Oncorhynchus nerka revealed a limited number of multivariable methods being applied and the sub-optimal reliance on univariable methods for multivariable problems. The literature review of fisheries science, general biology and medicine identified a large number of alternative methods for dealing with cumulative effects, with a limited number of techniques being used in fish migration studies. An evaluation of the different methods revealed that certain classes of multivariable analyses will probably prove useful in future assessments of cumulative effects on fish migration. This overview and evaluation of quantitative methods gathered from the disparate fields should serve as a primer for anyone seeking to quantify cumulative effects on fish migration survival. © 2012 The Authors. Journal of Fish Biology © 2012 The Fisheries Society of the British Isles.

  3. DREAM: a method for semi-quantitative dermal exposure assessment

    NARCIS (Netherlands)

    Wendel de Joode, B. van; Brouwer, D.H.; Kromhout, H.; Hemmen, J.J. van

    2003-01-01

    This paper describes a new method (DREAM) for structured, semi-quantitative dermal exposure assessment for chemical or biological agents that can be used in occupational hygiene or epidemiology. It is anticipated that DREAM could serve as an initial assessment of dermal exposure, amongst others,

  4. Quantitative bioanalytical and analytical method development of dibenzazepine derivative, carbamazepine: A review

    Directory of Open Access Journals (Sweden)

    Prasanna A. Datar

    2015-08-01

    Full Text Available Bioanalytical methods are widely used for quantitative estimation of drugs and their metabolites in physiological matrices. These methods could be applied to studies in areas of human clinical pharmacology and toxicology. The major bioanalytical services are method development, method validation and sample analysis (method application. Various methods such as GC, LC–MS/MS, HPLC, HPTLC, micellar electrokinetic chromatography, and UFLC have been used in laboratories for the qualitative and quantitative analysis of carbamazepine in biological samples throughout all phases of clinical research and quality control. The article incorporates various reported methods developed to help analysts in choosing crucial parameters for new method development of carbamazepine and its derivatives and also enumerates metabolites, and impurities reported so far. Keywords: Carbamazepine, HPLC, LC–MS/MS, HPTLC, RP-UFLC, Micellar electrokinetic chromatography

  5. Rigor mortis in an unusual position: Forensic considerations.

    Science.gov (United States)

    D'Souza, Deepak H; Harish, S; Rajesh, M; Kiran, J

    2011-07-01

    We report a case in which the dead body was found with rigor mortis in an unusual position. The dead body was lying on its back with limbs raised, defying gravity. Direction of the salivary stains on the face was also defying the gravity. We opined that the scene of occurrence of crime is unlikely to be the final place where the dead body was found. The clues were revealing a homicidal offence and an attempt to destroy the evidence. The forensic use of 'rigor mortis in an unusual position' is in furthering the investigations, and the scientific confirmation of two facts - the scene of death (occurrence) is different from the scene of disposal of dead body, and time gap between the two places.

  6. A quantitative assessment method for the NPP operators' diagnosis of accidents

    International Nuclear Information System (INIS)

    Kim, M. C.; Seong, P. H.

    2003-01-01

    In this research, we developed a quantitative model for the operators' diagnosis of the accident situation when an accident occurs in a nuclear power plant. After identifying the occurrence probabilities of accidents, the unavailabilities of various information sources, and the causal relationship between accidents and information sources, Bayesian network is used for the analysis of the change in the occurrence probabilities of accidents as the operators receive the information related to the status of the plant. The developed method is applied to a simple example case and it turned out that the developed method is a systematic quantitative analysis method which can cope with complex relationship between the accidents and information sources and various variables such accident occurrence probabilities and unavailabilities of various information sources

  7. On the use of quantitative methods in the Danish food industry

    DEFF Research Database (Denmark)

    Juhl, Hans Jørn; Østergaard, Peder; Kristensen, Kai

    1997-01-01

    Executive summary 1. The paper examines the use of quantitative methods in the Danish food industry and a comparison is made between the food industry and other manufacturing industries. Data was collected in 1991 and 107 manufacturing companies filled in the questionnaire. 20 of the companies were...... orientation is expected to lead to a more intensive use of proactive methods. It will be obvious to compare results from the new investigation with the results presented in this report in order to identify any trends in the use of quantitative methods....... in this paper does not lead to any striking differences between food companies and other manufacturing companies. In both cases there is a heavy concentration on methods used to analyze internal processes. 4. The increasing focus on food products ready for consumption and the general increase in focus on market...

  8. Effect of Pre-rigor Salting Levels on Physicochemical and Textural Properties of Chicken Breast Muscles

    Science.gov (United States)

    Choi, Yun-Sang

    2015-01-01

    This study was conducted to evaluate the effect of pre-rigor salting level (0-4% NaCl concentration) on physicochemical and textural properties of pre-rigor chicken breast muscles. The pre-rigor chicken breast muscles were de-boned 10 min post-mortem and salted within 25 min post-mortem. An increase in pre-rigor salting level led to the formation of high ultimate pH of chicken breast muscles at post-mortem 24 h. The addition of minimum of 2% NaCl significantly improved water holding capacity, cooking loss, protein solubility, and hardness when compared to the non-salting chicken breast muscle (psalting level caused the inhibition of myofibrillar protein degradation and the acceleration of lipid oxidation. However, the difference in NaCl concentration between 3% and 4% had no great differences in the results of physicochemical and textural properties due to pre-rigor salting effects (p>0.05). Therefore, our study certified the pre-rigor salting effect of chicken breast muscle salted with 2% NaCl when compared to post-rigor muscle salted with equal NaCl concentration, and suggests that the 2% NaCl concentration is minimally required to ensure the definite pre-rigor salting effect on chicken breast muscle. PMID:26761884

  9. Effect of Pre-rigor Salting Levels on Physicochemical and Textural Properties of Chicken Breast Muscles.

    Science.gov (United States)

    Kim, Hyun-Wook; Hwang, Ko-Eun; Song, Dong-Heon; Kim, Yong-Jae; Ham, Youn-Kyung; Yeo, Eui-Joo; Jeong, Tae-Jun; Choi, Yun-Sang; Kim, Cheon-Jei

    2015-01-01

    This study was conducted to evaluate the effect of pre-rigor salting level (0-4% NaCl concentration) on physicochemical and textural properties of pre-rigor chicken breast muscles. The pre-rigor chicken breast muscles were de-boned 10 min post-mortem and salted within 25 min post-mortem. An increase in pre-rigor salting level led to the formation of high ultimate pH of chicken breast muscles at post-mortem 24 h. The addition of minimum of 2% NaCl significantly improved water holding capacity, cooking loss, protein solubility, and hardness when compared to the non-salting chicken breast muscle (prigor salting level caused the inhibition of myofibrillar protein degradation and the acceleration of lipid oxidation. However, the difference in NaCl concentration between 3% and 4% had no great differences in the results of physicochemical and textural properties due to pre-rigor salting effects (p>0.05). Therefore, our study certified the pre-rigor salting effect of chicken breast muscle salted with 2% NaCl when compared to post-rigor muscle salted with equal NaCl concentration, and suggests that the 2% NaCl concentration is minimally required to ensure the definite pre-rigor salting effect on chicken breast muscle.

  10. Quantitation of valve regurgitation severity by three-dimensional vena contracta area is superior to flow convergence method of quantitation on transesophageal echocardiography.

    Science.gov (United States)

    Abudiab, Muaz M; Chao, Chieh-Ju; Liu, Shuang; Naqvi, Tasneem Z

    2017-07-01

    Quantitation of regurgitation severity using the proximal isovelocity acceleration (PISA) method to calculate effective regurgitant orifice (ERO) area has limitations. Measurement of three-dimensional (3D) vena contracta area (VCA) accurately grades mitral regurgitation (MR) severity on transthoracic echocardiography (TTE). We evaluated 3D VCA quantitation of regurgitant jet severity using 3D transesophageal echocardiography (TEE) in 110 native mitral, aortic, and tricuspid valves and six prosthetic valves in patients with at least mild valvular regurgitation. The ASE-recommended integrative method comprising semiquantitative and quantitative assessment of valvular regurgitation was used as a reference method, including ERO area by 2D PISA for assigning severity of regurgitation grade. Mean age was 62.2±14.4 years; 3D VCA quantitation was feasible in 91% regurgitant valves compared to 78% by the PISA method. When both methods were feasible and in the presence of a single regurgitant jet, 3D VCA and 2D PISA were similar in differentiating assigned severity (ANOVAP<.001). In valves with multiple jets, however, 3D VCA had a better correlation to assigned severity (ANOVAP<.0001). The agreement of 2D PISA and 3D VCA with the integrative method was 47% and 58% for moderate and 65% and 88% for severe regurgitation, respectively. Measurement of 3D VCA by TEE is superior to the 2D PISA method in determination of regurgitation severity in multiple native and prosthetic valves. © 2017, Wiley Periodicals, Inc.

  11. Reproducibility of CSF quantitative culture methods for estimating rate of clearance in cryptococcal meningitis.

    Science.gov (United States)

    Dyal, Jonathan; Akampurira, Andrew; Rhein, Joshua; Morawski, Bozena M; Kiggundu, Reuben; Nabeta, Henry W; Musubire, Abdu K; Bahr, Nathan C; Williams, Darlisha A; Bicanic, Tihana; Larsen, Robert A; Meya, David B; Boulware, David R

    2016-05-01

    Quantitative cerebrospinal fluid (CSF) cultures provide a measure of disease severity in cryptococcal meningitis. The fungal clearance rate by quantitative cultures has become a primary endpoint for phase II clinical trials. This study determined the inter-assay accuracy of three different quantitative culture methodologies. Among 91 participants with meningitis symptoms in Kampala, Uganda, during August-November 2013, 305 CSF samples were prospectively collected from patients at multiple time points during treatment. Samples were simultaneously cultured by three methods: (1) St. George's 100 mcl input volume of CSF with five 1:10 serial dilutions, (2) AIDS Clinical Trials Group (ACTG) method using 1000, 100, 10 mcl input volumes, and two 1:100 dilutions with 100 and 10 mcl input volume per dilution on seven agar plates; and (3) 10 mcl calibrated loop of undiluted and 1:100 diluted CSF (loop). Quantitative culture values did not statistically differ between St. George-ACTG methods (P= .09) but did for St. George-10 mcl loop (Pmethods was high (r≥0.88). For detecting sterility, the ACTG-method had the highest negative predictive value of 97% (91% St. George, 60% loop), but the ACTG-method had occasional (∼10%) difficulties in quantification due to colony clumping. For CSF clearance rate, St. George-ACTG methods did not differ overall (mean -0.05 ± 0.07 log10CFU/ml/day;P= .14) on a group level; however, individual-level clearance varied. The St. George and ACTG quantitative CSF culture methods produced comparable but not identical results. Quantitative cultures can inform treatment management strategies. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. Theory of stellar atmospheres an introduction to astrophysical non-equilibrium quantitative spectroscopic analysis

    CERN Document Server

    Hubeny, Ivan

    2015-01-01

    This book provides an in-depth and self-contained treatment of the latest advances achieved in quantitative spectroscopic analyses of the observable outer layers of stars and similar objects. Written by two leading researchers in the field, it presents a comprehensive account of both the physical foundations and numerical methods of such analyses. The book is ideal for astronomers who want to acquire deeper insight into the physical foundations of the theory of stellar atmospheres, or who want to learn about modern computational techniques for treating radiative transfer in non-equilibrium situations. It can also serve as a rigorous yet accessible introduction to the discipline for graduate students.

  13. From everyday communicative figurations to rigorous audience news repertoires: A mixed method approach to cross-media news consumption

    Directory of Open Access Journals (Sweden)

    Christian Kobbernagel

    2016-06-01

    Full Text Available In the last couple of decades there has been an unprecedented explosion of news media platforms and formats, as a succession of digital and social media have joined the ranks of legacy media. We live in a ‘hybrid media system’ (Chadwick, 2013, in which people build their cross-media news repertoires from the ensemble of old and new media available. This article presents an innovative mixed-method approach with considerable explanatory power to the exploration of patterns of news media consumption. This approach tailors Q-methodology in the direction of a qualitative study of news consumption, in which a card sorting exercise serves to translate the participants’ news media preferences into a form that enables the researcher to undertake a rigorous factor-analytical construction of their news consumption repertoires. This interpretive, factor-analytical procedure, which results in the building of six audience news repertoires in Denmark, also preserves the qualitative thickness of the participants’ verbal accounts of the communicative figurations of their day-in-the-life with the news media.

  14. An improved fast neutron radiography quantitative measurement method

    International Nuclear Information System (INIS)

    Matsubayashi, Masahito; Hibiki, Takashi; Mishima, Kaichiro; Yoshii, Koji; Okamoto, Koji

    2004-01-01

    The validity of a fast neutron radiography quantification method, the Σ-scaling method, which was originally proposed for thermal neutron radiography was examined with Monte Carlo calculations and experiments conducted at the YAYOI fast neutron source reactor. Water and copper were selected as comparative samples for a thermal neutron radiography case and a dense object, respectively. Although different characteristics on effective macroscopic cross-sections were implied by the simulation, the Σ-scaled experimental results with the fission neutron spectrum cross-sections were well fitted to the measurements for both the water and copper samples. This indicates that the Σ-scaling method could be successfully adopted for quantitative measurements in fast neutron radiography

  15. Comparison study on qualitative and quantitative risk assessment methods for urban natural gas pipeline network.

    Science.gov (United States)

    Han, Z Y; Weng, W G

    2011-05-15

    In this paper, a qualitative and a quantitative risk assessment methods for urban natural gas pipeline network are proposed. The qualitative method is comprised of an index system, which includes a causation index, an inherent risk index, a consequence index and their corresponding weights. The quantitative method consists of a probability assessment, a consequences analysis and a risk evaluation. The outcome of the qualitative method is a qualitative risk value, and for quantitative method the outcomes are individual risk and social risk. In comparison with previous research, the qualitative method proposed in this paper is particularly suitable for urban natural gas pipeline network, and the quantitative method takes different consequences of accidents into consideration, such as toxic gas diffusion, jet flame, fire ball combustion and UVCE. Two sample urban natural gas pipeline networks are used to demonstrate these two methods. It is indicated that both of the two methods can be applied to practical application, and the choice of the methods depends on the actual basic data of the gas pipelines and the precision requirements of risk assessment. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  16. Quantitative numerical method for analysing slip traces observed by AFM

    International Nuclear Information System (INIS)

    Veselý, J; Cieslar, M; Coupeau, C; Bonneville, J

    2013-01-01

    Atomic force microscopy (AFM) is used more and more routinely to study, at the nanometre scale, the slip traces produced on the surface of deformed crystalline materials. Taking full advantage of the quantitative height data of the slip traces, which can be extracted from these observations, requires however an adequate and robust processing of the images. In this paper an original method is presented, which allows the fitting of AFM scan-lines with a specific parameterized step function without any averaging treatment of the original data. This yields a quantitative and full description of the changes in step shape along the slip trace. The strength of the proposed method is established on several typical examples met in plasticity by analysing nano-scale structures formed on the sample surface by emerging dislocations. (paper)

  17. Moving beyond Data Transcription: Rigor as Issue in Representation of Digital Literacies

    Science.gov (United States)

    Hagood, Margaret Carmody; Skinner, Emily Neil

    2015-01-01

    Rigor in qualitative research has been based upon criteria of credibility, dependability, confirmability, and transferability. Drawing upon articles published during our editorship of the "Journal of Adolescent & Adult Literacy," we illustrate how the use of digital data in research study reporting may enhance these areas of rigor,…

  18. Quantitative Nuclear Medicine Imaging: Concepts, Requirements and Methods

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-01-15

    The absolute quantification of radionuclide distribution has been a goal since the early days of nuclear medicine. Nevertheless, the apparent complexity and sometimes limited accuracy of these methods have prevented them from being widely used in important applications such as targeted radionuclide therapy or kinetic analysis. The intricacy of the effects degrading nuclear medicine images and the lack of availability of adequate methods to compensate for these effects have frequently been seen as insurmountable obstacles in the use of quantitative nuclear medicine in clinical institutions. In the last few decades, several research groups have consistently devoted their efforts to the filling of these gaps. As a result, many efficient methods are now available that make quantification a clinical reality, provided appropriate compensation tools are used. Despite these efforts, many clinical institutions still lack the knowledge and tools to adequately measure and estimate the accumulated activities in the human body, thereby using potentially outdated protocols and procedures. The purpose of the present publication is to review the current state of the art of image quantification and to provide medical physicists and other related professionals facing quantification tasks with a solid background of tools and methods. It describes and analyses the physical effects that degrade image quality and affect the accuracy of quantification, and describes methods to compensate for them in planar, single photon emission computed tomography (SPECT) and positron emission tomography (PET) images. The fast paced development of the computational infrastructure, both hardware and software, has made drastic changes in the ways image quantification is now performed. The measuring equipment has evolved from the simple blind probes to planar and three dimensional imaging, supported by SPECT, PET and hybrid equipment. Methods of iterative reconstruction have been developed to allow for

  19. Quantitative Approach to Collaborative Learning: Performance Prediction, Individual Assessment, and Group Composition

    Science.gov (United States)

    Cen, Ling; Ruta, Dymitr; Powell, Leigh; Hirsch, Benjamin; Ng, Jason

    2016-01-01

    The benefits of collaborative learning, although widely reported, lack the quantitative rigor and detailed insight into the dynamics of interactions within the group, while individual contributions and their impacts on group members and their collaborative work remain hidden behind joint group assessment. To bridge this gap we intend to address…

  20. Criteria for quantitative and qualitative data integration: mixed-methods research methodology.

    Science.gov (United States)

    Lee, Seonah; Smith, Carrol A M

    2012-05-01

    Many studies have emphasized the need and importance of a mixed-methods approach for evaluation of clinical information systems. However, those studies had no criteria to guide integration of multiple data sets. Integrating different data sets serves to actualize the paradigm that a mixed-methods approach argues; thus, we require criteria that provide the right direction to integrate quantitative and qualitative data. The first author used a set of criteria organized from a literature search for integration of multiple data sets from mixed-methods research. The purpose of this article was to reorganize the identified criteria. Through critical appraisal of the reasons for designing mixed-methods research, three criteria resulted: validation, complementarity, and discrepancy. In applying the criteria to empirical data of a previous mixed methods study, integration of quantitative and qualitative data was achieved in a systematic manner. It helped us obtain a better organized understanding of the results. The criteria of this article offer the potential to produce insightful analyses of mixed-methods evaluations of health information systems.

  1. Trends in Methodological Rigor in Intervention Research Published in School Psychology Journals

    Science.gov (United States)

    Burns, Matthew K.; Klingbeil, David A.; Ysseldyke, James E.; Petersen-Brown, Shawna

    2012-01-01

    Methodological rigor in intervention research is important for documenting evidence-based practices and has been a recent focus in legislation, including the No Child Left Behind Act. The current study examined the methodological rigor of intervention research in four school psychology journals since the 1960s. Intervention research has increased…

  2. Quantitative Methods in Public Administration: their use and development through time

    NARCIS (Netherlands)

    Groeneveld, S.M.; Tummers, L.G.; Bronkhorst, B.A.C.; Ashikali, T.S.; van Thiel, S.

    2015-01-01

    This article aims to contribute to recent debates on research methods in public administration by examining the use of quantitative methods in public administration research. We analyzed 1,605 articles published between 2001-2010 in four leading journals: JPART, PAR, Governance and PA. Results show

  3. Quantitative impact characterization of aeronautical CFRP materials with non-destructive testing methods

    Energy Technology Data Exchange (ETDEWEB)

    Kiefel, Denis, E-mail: Denis.Kiefel@airbus.com, E-mail: Rainer.Stoessel@airbus.com; Stoessel, Rainer, E-mail: Denis.Kiefel@airbus.com, E-mail: Rainer.Stoessel@airbus.com [Airbus Group Innovations, Munich (Germany); Grosse, Christian, E-mail: Grosse@tum.de [Technical University Munich (Germany)

    2015-03-31

    In recent years, an increasing number of safety-relevant structures are designed and manufactured from carbon fiber reinforced polymers (CFRP) in order to reduce weight of airplanes by taking the advantage of their specific strength into account. Non-destructive testing (NDT) methods for quantitative defect analysis of damages are liquid- or air-coupled ultrasonic testing (UT), phased array ultrasonic techniques, and active thermography (IR). The advantage of these testing methods is the applicability on large areas. However, their quantitative information is often limited on impact localization and size. In addition to these techniques, Airbus Group Innovations operates a micro x-ray computed tomography (μ-XCT) system, which was developed for CFRP characterization. It is an open system which allows different kinds of acquisition, reconstruction, and data evaluation. One main advantage of this μ-XCT system is its high resolution with 3-dimensional analysis and visualization opportunities, which enables to gain important quantitative information for composite part design and stress analysis. Within this study, different NDT methods will be compared at CFRP samples with specified artificial impact damages. The results can be used to select the most suitable NDT-method for specific application cases. Furthermore, novel evaluation and visualization methods for impact analyzes are developed and will be presented.

  4. Quantitative impact characterization of aeronautical CFRP materials with non-destructive testing methods

    International Nuclear Information System (INIS)

    Kiefel, Denis; Stoessel, Rainer; Grosse, Christian

    2015-01-01

    In recent years, an increasing number of safety-relevant structures are designed and manufactured from carbon fiber reinforced polymers (CFRP) in order to reduce weight of airplanes by taking the advantage of their specific strength into account. Non-destructive testing (NDT) methods for quantitative defect analysis of damages are liquid- or air-coupled ultrasonic testing (UT), phased array ultrasonic techniques, and active thermography (IR). The advantage of these testing methods is the applicability on large areas. However, their quantitative information is often limited on impact localization and size. In addition to these techniques, Airbus Group Innovations operates a micro x-ray computed tomography (μ-XCT) system, which was developed for CFRP characterization. It is an open system which allows different kinds of acquisition, reconstruction, and data evaluation. One main advantage of this μ-XCT system is its high resolution with 3-dimensional analysis and visualization opportunities, which enables to gain important quantitative information for composite part design and stress analysis. Within this study, different NDT methods will be compared at CFRP samples with specified artificial impact damages. The results can be used to select the most suitable NDT-method for specific application cases. Furthermore, novel evaluation and visualization methods for impact analyzes are developed and will be presented

  5. Biomedical text mining for research rigor and integrity: tasks, challenges, directions.

    Science.gov (United States)

    Kilicoglu, Halil

    2017-06-13

    An estimated quarter of a trillion US dollars is invested in the biomedical research enterprise annually. There is growing alarm that a significant portion of this investment is wasted because of problems in reproducibility of research findings and in the rigor and integrity of research conduct and reporting. Recent years have seen a flurry of activities focusing on standardization and guideline development to enhance the reproducibility and rigor of biomedical research. Research activity is primarily communicated via textual artifacts, ranging from grant applications to journal publications. These artifacts can be both the source and the manifestation of practices leading to research waste. For example, an article may describe a poorly designed experiment, or the authors may reach conclusions not supported by the evidence presented. In this article, we pose the question of whether biomedical text mining techniques can assist the stakeholders in the biomedical research enterprise in doing their part toward enhancing research integrity and rigor. In particular, we identify four key areas in which text mining techniques can make a significant contribution: plagiarism/fraud detection, ensuring adherence to reporting guidelines, managing information overload and accurate citation/enhanced bibliometrics. We review the existing methods and tools for specific tasks, if they exist, or discuss relevant research that can provide guidance for future work. With the exponential increase in biomedical research output and the ability of text mining approaches to perform automatic tasks at large scale, we propose that such approaches can support tools that promote responsible research practices, providing significant benefits for the biomedical research enterprise. Published by Oxford University Press 2017. This work is written by a US Government employee and is in the public domain in the US.

  6. A quantitative method to measure and evaluate the peelability of shrimps (Pandalus borealis)

    DEFF Research Database (Denmark)

    Gringer, Nina; Dang, Tem Thi; Orlien, Vibeke

    2018-01-01

    A novel, standardized method has been developed in order to provide a quantitative description of shrimp peelability. The peeling process was based on the measure of the strength of the shell-muscle attachment of the shrimp using a texture analyzer, and calculated into the peeling work. The self......-consistent method, insensitive of the shrimp size, was proven valid for assessment of ice maturation of shrimps. The quantitative peeling efficiency (peeling work) and performance (degree of shell removal) showed that the decrease in peeling work correlated with the amount of satisfactory peeled shrimps, indicating...... an effective weakening of the shell-muscle attachment. The developed method provides the industry with a quantitative analysis for measurement of peeling efficiency and peeling performance of shrimps. It may be used for comparing different maturation conditions in relation to optimization of shrimps peeling....

  7. Quantitative analysis of culture using millions of digitized books.

    Science.gov (United States)

    Michel, Jean-Baptiste; Shen, Yuan Kui; Aiden, Aviva Presser; Veres, Adrian; Gray, Matthew K; Pickett, Joseph P; Hoiberg, Dale; Clancy, Dan; Norvig, Peter; Orwant, Jon; Pinker, Steven; Nowak, Martin A; Aiden, Erez Lieberman

    2011-01-14

    We constructed a corpus of digitized texts containing about 4% of all books ever printed. Analysis of this corpus enables us to investigate cultural trends quantitatively. We survey the vast terrain of 'culturomics,' focusing on linguistic and cultural phenomena that were reflected in the English language between 1800 and 2000. We show how this approach can provide insights about fields as diverse as lexicography, the evolution of grammar, collective memory, the adoption of technology, the pursuit of fame, censorship, and historical epidemiology. Culturomics extends the boundaries of rigorous quantitative inquiry to a wide array of new phenomena spanning the social sciences and the humanities.

  8. Quantitative analysis of culture using millions of digitized books

    Science.gov (United States)

    Michel, Jean-Baptiste; Shen, Yuan Kui; Aiden, Aviva P.; Veres, Adrian; Gray, Matthew K.; Pickett, Joseph P.; Hoiberg, Dale; Clancy, Dan; Norvig, Peter; Orwant, Jon; Pinker, Steven; Nowak, Martin A.; Aiden, Erez Lieberman

    2011-01-01

    We constructed a corpus of digitized texts containing about 4% of all books ever printed. Analysis of this corpus enables us to investigate cultural trends quantitatively. We survey the vast terrain of ‘culturomics’, focusing on linguistic and cultural phenomena that were reflected in the English language between 1800 and 2000. We show how this approach can provide insights about fields as diverse as lexicography, the evolution of grammar, collective memory, the adoption of technology, the pursuit of fame, censorship, and historical epidemiology. ‘Culturomics’ extends the boundaries of rigorous quantitative inquiry to a wide array of new phenomena spanning the social sciences and the humanities. PMID:21163965

  9. Concrete ensemble Kalman filters with rigorous catastrophic filter divergence.

    Science.gov (United States)

    Kelly, David; Majda, Andrew J; Tong, Xin T

    2015-08-25

    The ensemble Kalman filter and ensemble square root filters are data assimilation methods used to combine high-dimensional, nonlinear dynamical models with observed data. Ensemble methods are indispensable tools in science and engineering and have enjoyed great success in geophysical sciences, because they allow for computationally cheap low-ensemble-state approximation for extremely high-dimensional turbulent forecast models. From a theoretical perspective, the dynamical properties of these methods are poorly understood. One of the central mysteries is the numerical phenomenon known as catastrophic filter divergence, whereby ensemble-state estimates explode to machine infinity, despite the true state remaining in a bounded region. In this article we provide a breakthrough insight into the phenomenon, by introducing a simple and natural forecast model that transparently exhibits catastrophic filter divergence under all ensemble methods and a large set of initializations. For this model, catastrophic filter divergence is not an artifact of numerical instability, but rather a true dynamical property of the filter. The divergence is not only validated numerically but also proven rigorously. The model cleanly illustrates mechanisms that give rise to catastrophic divergence and confirms intuitive accounts of the phenomena given in past literature.

  10. Nailfold capillaroscopic report: qualitative and quantitative methods

    Directory of Open Access Journals (Sweden)

    S. Zeni

    2011-09-01

    Full Text Available Nailfold capillaroscopy (NVC is a simple and non-invasive method used for the assessment of patients with Raynaud’s phenomenon (RP and in the differential diagnosis of various connective tissue diseases. The scleroderma pattern abnormalities (giant capillaries, haemorrages and/or avascular areas have a positive predictive value for the development of scleroderma spectrum disorders. Thus, an analytical approach to nailfold capillaroscopy can be useful in quantitatively and reproducibly recording various parameters. We developed a new method to assess patients with RP that is capable of predicting the 5-year transition from isolated RP to RP secondary to scleroderma spectrum disorders. This model is a weighted combination of different capillaroscopic parameters (giant capillaries, microhaemorrages, number of capillaries that allows physicians to stratify RP patients easily using a relatively simple diagram to deduce prognosis.

  11. Rigorous Combination of GNSS and VLBI: How it Improves Earth Orientation and Reference Frames

    Science.gov (United States)

    Lambert, S. B.; Richard, J. Y.; Bizouard, C.; Becker, O.

    2017-12-01

    Current reference series (C04) of the International Earth Rotation and Reference Systems Service (IERS) are produced by a weighted combination of Earth orientation parameters (EOP) time series built up by combination centers of each technique (VLBI, GNSS, Laser ranging, DORIS). In the future, we plan to derive EOP from a rigorous combination of the normal equation systems of the four techniques.We present here the results of a rigorous combination of VLBI and GNSS pre-reduced, constraint-free, normal equations with the DYNAMO geodetic analysis software package developed and maintained by the French GRGS (Groupe de Recherche en GeÌodeÌsie Spatiale). The used normal equations are those produced separately by the IVS and IGS combination centers to which we apply our own minimal constraints.We address the usefulness of such a method with respect to the classical, a posteriori, combination method, and we show whether EOP determinations are improved.Especially, we implement external validations of the EOP series based on comparison with geophysical excitation and examination of the covariance matrices. Finally, we address the potential of the technique for the next generation celestial reference frames, which are currently determined by VLBI only.

  12. Quantitative Efficiency Evaluation Method for Transportation Networks

    Directory of Open Access Journals (Sweden)

    Jin Qin

    2014-11-01

    Full Text Available An effective evaluation of transportation network efficiency/performance is essential to the establishment of sustainable development in any transportation system. Based on a redefinition of transportation network efficiency, a quantitative efficiency evaluation method for transportation network is proposed, which could reflect the effects of network structure, traffic demands, travel choice, and travel costs on network efficiency. Furthermore, the efficiency-oriented importance measure for network components is presented, which can be used to help engineers identify the critical nodes and links in the network. The numerical examples show that, compared with existing efficiency evaluation methods, the network efficiency value calculated by the method proposed in this paper can portray the real operation situation of the transportation network as well as the effects of main factors on network efficiency. We also find that the network efficiency and the importance values of the network components both are functions of demands and network structure in the transportation network.

  13. Mixed methods in gerontological research: Do the qualitative and quantitative data “touch”?

    Science.gov (United States)

    Happ, Mary Beth

    2010-01-01

    This paper distinguishes between parallel and integrated mixed methods research approaches. Barriers to integrated mixed methods approaches in gerontological research are discussed and critiqued. The author presents examples of mixed methods gerontological research to illustrate approaches to data integration at the levels of data analysis, interpretation, and research reporting. As a summary of the methodological literature, four basic levels of mixed methods data combination are proposed. Opportunities for mixing qualitative and quantitative data are explored using contemporary examples from published studies. Data transformation and visual display, judiciously applied, are proposed as pathways to fuller mixed methods data integration and analysis. Finally, practical strategies for mixing qualitative and quantitative data types are explicated as gerontological research moves beyond parallel mixed methods approaches to achieve data integration. PMID:20077973

  14. A novel method for quantitative geosteering using azimuthal gamma-ray logging

    International Nuclear Information System (INIS)

    Yuan, Chao; Zhou, Cancan; Zhang, Feng; Hu, Song; Li, Chaoliu

    2015-01-01

    A novel method for quantitative geosteering by using azimuthal gamma-ray logging is proposed. Real-time up and bottom gamma-ray logs when a logging tool travels through a boundary surface with different relative dip angles are simulated with the Monte Carlo method. Study results show that response points of up and bottom gamma-ray logs when the logging tool moves towards a highly radioactive formation can be used to predict the relative dip angle, and then the distance from the drilling bit to the boundary surface is calculated. - Highlights: • A new method is proposed for geosteering by using azimuthal gamma-ray logging. • The new method can quantitatively determine the distance from the drilling bit to the boundary surface while the traditional geosteering method can only qualitatively guide the drilling bit in reservoirs. • The response points of real-time upper and lower gamma line when the logging tool meets high radioactive formation are used to predict the relative dip angles, and then the distance from the drilling bit to the boundary surface is calculated

  15. Applying quantitative benefit-risk analysis to aid regulatory decision making in diagnostic imaging: methods, challenges, and opportunities.

    Science.gov (United States)

    Agapova, Maria; Devine, Emily Beth; Bresnahan, Brian W; Higashi, Mitchell K; Garrison, Louis P

    2014-09-01

    Health agencies making regulatory marketing-authorization decisions use qualitative and quantitative approaches to assess expected benefits and expected risks associated with medical interventions. There is, however, no universal standard approach that regulatory agencies consistently use to conduct benefit-risk assessment (BRA) for pharmaceuticals or medical devices, including for imaging technologies. Economics, health services research, and health outcomes research use quantitative approaches to elicit preferences of stakeholders, identify priorities, and model health conditions and health intervention effects. Challenges to BRA in medical devices are outlined, highlighting additional barriers in radiology. Three quantitative methods--multi-criteria decision analysis, health outcomes modeling and stated-choice survey--are assessed using criteria that are important in balancing benefits and risks of medical devices and imaging technologies. To be useful in regulatory BRA, quantitative methods need to: aggregate multiple benefits and risks, incorporate qualitative considerations, account for uncertainty, and make clear whose preferences/priorities are being used. Each quantitative method performs differently across these criteria and little is known about how BRA estimates and conclusions vary by approach. While no specific quantitative method is likely to be the strongest in all of the important areas, quantitative methods may have a place in BRA of medical devices and radiology. Quantitative BRA approaches have been more widely applied in medicines, with fewer BRAs in devices. Despite substantial differences in characteristics of pharmaceuticals and devices, BRA methods may be as applicable to medical devices and imaging technologies as they are to pharmaceuticals. Further research to guide the development and selection of quantitative BRA methods for medical devices and imaging technologies is needed. Copyright © 2014 AUR. Published by Elsevier Inc. All rights

  16. Report of the methods for quantitative organ evaluation in nuclear medicine

    International Nuclear Information System (INIS)

    Nakata, Shigeru; Akagi, Naoki; Mimura, Hiroaki; Nagaki, Akio; Takahashi, Yasuyuki

    1999-01-01

    The group for the methods in the title herein reported the summary of their investigations on literatures concerning the brain, heart, liver and kidney evaluation. The report consisted of the history, kinetics of the agents, methods for quantitative evaluation and summary for each organ. As for the brain, the quantitative evaluation of cerebral blood flow scintigraphy with 123 I-IMP and 99m Tc-HMPAO or -ECD were reviewed to conclude that the present convenient methods are of problems in precision, for which a novel method and/or tracer should be developed. For cardiac functions, there is a method based either on the behavior of tracer in the blood which is excellent in reproducibility, or on the morphology of cardiac wall of which images can be analyzed alternatively by CT and MRI. For these, 131 I-albumin, 99m Tc-albumin, -red blood cells, -MIBI and -tetrofosmin have been used. For myocardium, 201 Tl has been used to evaluate the ischemic region and, with simultaneous use of 99m Tc-MIBI or -tetrofosmin, the viability. 123 I-BMIPP and -MIBG have been developed for myocardial fatty acid metabolism and for cardiac sympathetic nerve functions. Liver functions have been evaluated by the blood elimination rate, hepatic uptake, hepatic elimination and hepatic blood flow with use of 99m Tc-labeled colloids, -PMT and -GSA. Quantitative evaluation of renal functions is now well established with high precision since the kinetic behavior of the tracers, like 99m Tc-DTPA, -MAG3, -DMSA and 131 I-OIH, is simple. (K.H.)

  17. A quantitative method for measuring the quality of history matches

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, T.S. [Kerr-McGee Corp., Oklahoma City, OK (United States); Knapp, R.M. [Univ. of Oklahoma, Norman, OK (United States)

    1997-08-01

    History matching can be an efficient tool for reservoir characterization. A {open_quotes}good{close_quotes} history matching job can generate reliable reservoir parameters. However, reservoir engineers are often frustrated when they try to select a {open_quotes}better{close_quotes} match from a series of history matching runs. Without a quantitative measurement, it is always difficult to tell the difference between a {open_quotes}good{close_quotes} and a {open_quotes}better{close_quotes} matches. For this reason, we need a quantitative method for testing the quality of matches. This paper presents a method for such a purpose. The method uses three statistical indices to (1) test shape conformity, (2) examine bias errors, and (3) measure magnitude of deviation. The shape conformity test insures that the shape of a simulated curve matches that of a historical curve. Examining bias errors assures that model reservoir parameters have been calibrated to that of a real reservoir. Measuring the magnitude of deviation assures that the difference between the model and the real reservoir parameters is minimized. The method was first tested on a hypothetical model and then applied to published field studies. The results showed that the method can efficiently measure the quality of matches. It also showed that the method can serve as a diagnostic tool for calibrating reservoir parameters during history matching.

  18. Microchromatography of hemoglobins. VIII. A general qualitative and quantitative method in plastic drinking straws and the quantitative analysis of Hb-F.

    Science.gov (United States)

    Schroeder, W A; Pace, L A

    1978-03-01

    The microchromatographic procedure for the quantitative analysis of the hemoglobin components in a hemolysate uses columns of DEAE-cellulose in a plastic drinking straw with a glycine-KCN-NaCl developer. Not only may the method be used for the quantitative analysis of Hb-F but also for the analysis of the varied components in mixtures of hemoglobins.

  19. Rigorous Photogrammetric Processing of CHANG'E-1 and CHANG'E-2 Stereo Imagery for Lunar Topographic Mapping

    Science.gov (United States)

    Di, K.; Liu, Y.; Liu, B.; Peng, M.

    2012-07-01

    Chang'E-1(CE-1) and Chang'E-2(CE-2) are the two lunar orbiters of China's lunar exploration program. Topographic mapping using CE-1 and CE-2 images is of great importance for scientific research as well as for preparation of landing and surface operation of Chang'E-3 lunar rover. In this research, we developed rigorous sensor models of CE-1 and CE-2 CCD cameras based on push-broom imaging principle with interior and exterior orientation parameters. Based on the rigorous sensor model, the 3D coordinate of a ground point in lunar body-fixed (LBF) coordinate system can be calculated by space intersection from the image coordinates of con-jugate points in stereo images, and the image coordinates can be calculated from 3D coordinates by back-projection. Due to uncer-tainties of the orbit and the camera, the back-projected image points are different from the measured points. In order to reduce these inconsistencies and improve precision, we proposed two methods to refine the rigorous sensor model: 1) refining EOPs by correcting the attitude angle bias, 2) refining the interior orientation model by calibration of the relative position of the two linear CCD arrays. Experimental results show that the mean back-projection residuals of CE-1 images are reduced to better than 1/100 pixel by method 1 and the mean back-projection residuals of CE-2 images are reduced from over 20 pixels to 0.02 pixel by method 2. Consequently, high precision DEM (Digital Elevation Model) and DOM (Digital Ortho Map) are automatically generated.

  20. Power Mobility Training Methods for Children: A Systematic Review.

    Science.gov (United States)

    Kenyon, Lisa K; Hostnik, Lisa; McElroy, Rachel; Peterson, Courtney; Farris, John P

    2018-01-01

    To summarize and critically appraise the existing evidence related to power mobility training methods used in research studies conducted with children 21 years or younger. A systematic review was conducted using 16 electronic databases to identify primary source quantitative studies published in peer-reviewed journals. Data extraction, determination of level of evidence, evaluation of methodological rigor, and assessment of the risk of bias were completed. The Evidence Alert Traffic Light Grading System (EATLS) was used. Twenty-seven studies were included in the review. Levels of evidence were II to V; scientific rigor scores were 2 to 7. An overall Yellow EATLS level of evidence was found indicating that therapists should use caution when providing power mobility training interventions and measure outcomes related to established goals in areas such as development, functional skills, or use of a power mobility device.

  1. Visual and Quantitative Analysis Methods of Respiratory Patterns for Respiratory Gated PET/CT.

    Science.gov (United States)

    Son, Hye Joo; Jeong, Young Jin; Yoon, Hyun Jin; Park, Jong-Hwan; Kang, Do-Young

    2016-01-01

    We integrated visual and quantitative methods for analyzing the stability of respiration using four methods: phase space diagrams, Fourier spectra, Poincaré maps, and Lyapunov exponents. Respiratory patterns of 139 patients were grouped based on the combination of the regularity of amplitude, period, and baseline positions. Visual grading was done by inspecting the shape of diagram and classified into two states: regular and irregular. Quantitation was done by measuring standard deviation of x and v coordinates of Poincaré map (SD x , SD v ) or the height of the fundamental peak ( A 1 ) in Fourier spectrum or calculating the difference between maximal upward and downward drift. Each group showed characteristic pattern on visual analysis. There was difference of quantitative parameters (SD x , SD v , A 1 , and MUD-MDD) among four groups (one way ANOVA, p = 0.0001 for MUD-MDD, SD x , and SD v , p = 0.0002 for A 1 ). In ROC analysis, the cutoff values were 0.11 for SD x (AUC: 0.982, p quantitative indices of respiratory stability and determining quantitative cutoff value for differentiating regular and irregular respiration.

  2. Effects of rigor status during high-pressure processing on the physical qualities of farm-raised abalone (Haliotis rufescens).

    Science.gov (United States)

    Hughes, Brianna H; Greenberg, Neil J; Yang, Tom C; Skonberg, Denise I

    2015-01-01

    High-pressure processing (HPP) is used to increase meat safety and shelf-life, with conflicting quality effects depending on rigor status during HPP. In the seafood industry, HPP is used to shuck and pasteurize oysters, but its use on abalones has only been minimally evaluated and the effect of rigor status during HPP on abalone quality has not been reported. Farm-raised abalones (Haliotis rufescens) were divided into 12 HPP treatments and 1 unprocessed control treatment. Treatments were processed pre-rigor or post-rigor at 2 pressures (100 and 300 MPa) and 3 processing times (1, 3, and 5 min). The control was analyzed post-rigor. Uniform plugs were cut from adductor and foot meat for texture profile analysis, shear force, and color analysis. Subsamples were used for scanning electron microscopy of muscle ultrastructure. Texture profile analysis revealed that post-rigor processed abalone was significantly (P abalone meat was more tender than pre-rigor processed meat, and post-rigor processed foot meat was lighter in color than pre-rigor processed foot meat, suggesting that waiting for rigor to resolve prior to processing abalones may improve consumer perceptions of quality and market value. © 2014 Institute of Food Technologists®

  3. A Framework for Mixing Methods in Quantitative Measurement Development, Validation, and Revision: A Case Study

    Science.gov (United States)

    Luyt, Russell

    2012-01-01

    A framework for quantitative measurement development, validation, and revision that incorporates both qualitative and quantitative methods is introduced. It extends and adapts Adcock and Collier's work, and thus, facilitates understanding of quantitative measurement development, validation, and revision as an integrated and cyclical set of…

  4. Quantitative methods in electroencephalography to access therapeutic response.

    Science.gov (United States)

    Diniz, Roseane Costa; Fontenele, Andrea Martins Melo; Carmo, Luiza Helena Araújo do; Ribeiro, Aurea Celeste da Costa; Sales, Fábio Henrique Silva; Monteiro, Sally Cristina Moutinho; Sousa, Ana Karoline Ferreira de Castro

    2016-07-01

    Pharmacometrics or Quantitative Pharmacology aims to quantitatively analyze the interaction between drugs and patients whose tripod: pharmacokinetics, pharmacodynamics and disease monitoring to identify variability in drug response. Being the subject of central interest in the training of pharmacists, this work was out with a view to promoting this idea on methods to access the therapeutic response of drugs with central action. This paper discusses quantitative methods (Fast Fourier Transform, Magnitude Square Coherence, Conditional Entropy, Generalised Linear semi-canonical Correlation Analysis, Statistical Parametric Network and Mutual Information Function) used to evaluate the EEG signals obtained after administration regimen of drugs, the main findings and their clinical relevance, pointing it as a contribution to construction of different pharmaceutical practice. Peter Anderer et. al in 2000 showed the effect of 20mg of buspirone in 20 healthy subjects after 1, 2, 4, 6 and 8h after oral ingestion of the drug. The areas of increased power of the theta frequency occurred mainly in the temporo-occipital - parietal region. It has been shown by Sampaio et al., 2007 that the use of bromazepam, which allows the release of GABA (gamma amino butyric acid), an inhibitory neurotransmitter of the central nervous system could theoretically promote dissociation of cortical functional areas, a decrease of functional connectivity, a decrease of cognitive functions by means of smaller coherence (electrophysiological magnitude measured from the EEG by software) values. Ahmad Khodayari-Rostamabad et al. in 2015 talk that such a measure could be a useful clinical tool potentially to assess adverse effects of opioids and hence give rise to treatment guidelines. There was the relation between changes in pain intensity and brain sources (at maximum activity locations) during remifentanil infusion despite its potent analgesic effect. The statement of mathematical and computational

  5. Some rigorous results concerning spectral theory for ideal MHD

    International Nuclear Information System (INIS)

    Laurence, P.

    1986-01-01

    Spectral theory for linear ideal MHD is laid on a firm foundation by defining appropriate function spaces for the operators associated with both the first- and second-order (in time and space) partial differential operators. Thus, it is rigorously established that a self-adjoint extension of F(xi) exists. It is shown that the operator L associated with the first-order formulation satisfies the conditions of the Hille--Yosida theorem. A foundation is laid thereby within which the domains associated with the first- and second-order formulations can be compared. This allows future work in a rigorous setting that will clarify the differences (in the two formulations) between the structure of the generalized eigenspaces corresponding to the marginal point of the spectrum ω = 0

  6. Some rigorous results concerning spectral theory for ideal MHD

    International Nuclear Information System (INIS)

    Laurence, P.

    1985-05-01

    Spectral theory for linear ideal MHD is laid on a firm foundation by defining appropriate function spaces for the operators associated with both the first and second order (in time and space) partial differential operators. Thus, it is rigorously established that a self-adjoint extension of F(xi) exists. It is shown that the operator L associated with the first order formulation satisfies the conditions of the Hille-Yosida theorem. A foundation is laid thereby within which the domains associated with the first and second order formulations can be compared. This allows future work in a rigorous setting that will clarify the differences (in the two formulations) between the structure of the generalized eigenspaces corresponding to the marginal point of the spectrum ω = 0

  7. The influence of biological and technical factors on quantitative analysis of amyloid PET: Points to consider and recommendations for controlling variability in longitudinal data.

    Science.gov (United States)

    Schmidt, Mark E; Chiao, Ping; Klein, Gregory; Matthews, Dawn; Thurfjell, Lennart; Cole, Patricia E; Margolin, Richard; Landau, Susan; Foster, Norman L; Mason, N Scott; De Santi, Susan; Suhy, Joyce; Koeppe, Robert A; Jagust, William

    2015-09-01

    In vivo imaging of amyloid burden with positron emission tomography (PET) provides a means for studying the pathophysiology of Alzheimer's and related diseases. Measurement of subtle changes in amyloid burden requires quantitative analysis of image data. Reliable quantitative analysis of amyloid PET scans acquired at multiple sites and over time requires rigorous standardization of acquisition protocols, subject management, tracer administration, image quality control, and image processing and analysis methods. We review critical points in the acquisition and analysis of amyloid PET, identify ways in which technical factors can contribute to measurement variability, and suggest methods for mitigating these sources of noise. Improved quantitative accuracy could reduce the sample size necessary to detect intervention effects when amyloid PET is used as a treatment end point and allow more reliable interpretation of change in amyloid burden and its relationship to clinical course. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  8. MR Imaging-based Semi-quantitative Methods for Knee Osteoarthritis

    Science.gov (United States)

    JARRAYA, Mohamed; HAYASHI, Daichi; ROEMER, Frank Wolfgang; GUERMAZI, Ali

    2016-01-01

    Magnetic resonance imaging (MRI)-based semi-quantitative (SQ) methods applied to knee osteoarthritis (OA) have been introduced during the last decade and have fundamentally changed our understanding of knee OA pathology since then. Several epidemiological studies and clinical trials have used MRI-based SQ methods to evaluate different outcome measures. Interest in MRI-based SQ scoring system has led to continuous update and refinement. This article reviews the different SQ approaches for MRI-based whole organ assessment of knee OA and also discuss practical aspects of whole joint assessment. PMID:26632537

  9. [A new method of calibration and positioning in quantitative analysis of multicomponents by single marker].

    Science.gov (United States)

    He, Bing; Yang, Shi-Yan; Zhang, Yan

    2012-12-01

    This paper aims to establish a new method of calibration and positioning in quantitative analysis of multicomponents by single marker (QAMS), using Shuanghuanglian oral liquid as the research object. Establishing relative correction factors with reference chlorogenic acid to other 11 active components (neochlorogenic acid, cryptochlorogenic acid, cafferic acid, forsythoside A, scutellarin, isochlorogenic acid B, isochlorogenic acid A, isochlorogenic acid C, baicalin and phillyrin wogonoside) in Shuanghuanglian oral liquid by 3 correction methods (multipoint correction, slope correction and quantitative factor correction). At the same time chromatographic peak was positioned by linear regression method. Only one standard uas used to determine the content of 12 components in Shuanghuanglian oral liquid, in stead of needing too many reference substance in quality control. The results showed that within the linear ranges, no significant differences were found in the quantitative results of 12 active constituents in 3 batches of Shuanghuanglian oral liquid determined by 3 correction methods and external standard method (ESM) or standard curve method (SCM). And this method is simpler and quicker than literature methods. The results were accurate and reliable, and had good reproducibility. While the positioning chromatographic peaks by linear regression method was more accurate than relative retention time in literature. The slope and the quantitative factor correction controlling the quality of Chinese traditional medicine is feasible and accurate.

  10. Guidelines for conducting rigorous health care psychosocial cross-cultural/language qualitative research.

    Science.gov (United States)

    Arriaza, Pablo; Nedjat-Haiem, Frances; Lee, Hee Yun; Martin, Shadi S

    2015-01-01

    The purpose of this article is to synthesize and chronicle the authors' experiences as four bilingual and bicultural researchers, each experienced in conducting cross-cultural/cross-language qualitative research. Through narrative descriptions of experiences with Latinos, Iranians, and Hmong refugees, the authors discuss their rewards, challenges, and methods of enhancing rigor, trustworthiness, and transparency when conducting cross-cultural/cross-language research. The authors discuss and explore how to effectively manage cross-cultural qualitative data, how to effectively use interpreters and translators, how to identify best methods of transcribing data, and the role of creating strong community relationships. The authors provide guidelines for health care professionals to consider when engaging in cross-cultural qualitative research.

  11. Quantitative, Qualitative and Geospatial Methods to Characterize HIV Risk Environments.

    Directory of Open Access Journals (Sweden)

    Erin E Conners

    Full Text Available Increasingly, 'place', including physical and geographical characteristics as well as social meanings, is recognized as an important factor driving individual and community health risks. This is especially true among marginalized populations in low and middle income countries (LMIC, whose environments may also be more difficult to study using traditional methods. In the NIH-funded longitudinal study Mapa de Salud, we employed a novel approach to exploring the risk environment of female sex workers (FSWs in two Mexico/U.S. border cities, Tijuana and Ciudad Juárez. In this paper we describe the development, implementation, and feasibility of a mix of quantitative and qualitative tools used to capture the HIV risk environments of FSWs in an LMIC setting. The methods were: 1 Participatory mapping; 2 Quantitative interviews; 3 Sex work venue field observation; 4 Time-location-activity diaries; 5 In-depth interviews about daily activity spaces. We found that the mixed-methodology outlined was both feasible to implement and acceptable to participants. These methods can generate geospatial data to assess the role of the environment on drug and sexual risk behaviors among high risk populations. Additionally, the adaptation of existing methods for marginalized populations in resource constrained contexts provides new opportunities for informing public health interventions.

  12. A scoring system for appraising mixed methods research, and concomitantly appraising qualitative, quantitative and mixed methods primary studies in Mixed Studies Reviews.

    Science.gov (United States)

    Pluye, Pierre; Gagnon, Marie-Pierre; Griffiths, Frances; Johnson-Lafleur, Janique

    2009-04-01

    A new form of literature review has emerged, Mixed Studies Review (MSR). These reviews include qualitative, quantitative and mixed methods studies. In the present paper, we examine MSRs in health sciences, and provide guidance on processes that should be included and reported. However, there are no valid and usable criteria for concomitantly appraising the methodological quality of the qualitative, quantitative and mixed methods studies. To propose criteria for concomitantly appraising the methodological quality of qualitative, quantitative and mixed methods studies or study components. A three-step critical review was conducted. 2322 references were identified in MEDLINE, and their titles and abstracts were screened; 149 potentially relevant references were selected and the full-text papers were examined; 59 MSRs were retained and scrutinized using a deductive-inductive qualitative thematic data analysis. This revealed three types of MSR: convenience, reproducible, and systematic. Guided by a proposal, we conducted a qualitative thematic data analysis of the quality appraisal procedures used in the 17 systematic MSRs (SMSRs). Of 17 SMSRs, 12 showed clear quality appraisal procedures with explicit criteria but no SMSR used valid checklists to concomitantly appraise qualitative, quantitative and mixed methods studies. In two SMSRs, criteria were developed following a specific procedure. Checklists usually contained more criteria than needed. In four SMSRs, a reliability assessment was described or mentioned. While criteria for quality appraisal were usually based on descriptors that require specific methodological expertise (e.g., appropriateness), no SMSR described the fit between reviewers' expertise and appraised studies. Quality appraisal usually resulted in studies being ranked by methodological quality. A scoring system is proposed for concomitantly appraising the methodological quality of qualitative, quantitative and mixed methods studies for SMSRs. This

  13. Quantitative magnetic resonance micro-imaging methods for pharmaceutical research.

    Science.gov (United States)

    Mantle, M D

    2011-09-30

    The use of magnetic resonance imaging (MRI) as a tool in pharmaceutical research is now well established and the current literature covers a multitude of different pharmaceutically relevant research areas. This review focuses on the use of quantitative magnetic resonance micro-imaging techniques and how they have been exploited to extract information that is of direct relevance to the pharmaceutical industry. The article is divided into two main areas. The first half outlines the theoretical aspects of magnetic resonance and deals with basic magnetic resonance theory, the effects of nuclear spin-lattice (T(1)), spin-spin (T(2)) relaxation and molecular diffusion upon image quantitation, and discusses the applications of rapid magnetic resonance imaging techniques. In addition to the theory, the review aims to provide some practical guidelines for the pharmaceutical researcher with an interest in MRI as to which MRI pulse sequences/protocols should be used and when. The second half of the article reviews the recent advances and developments that have appeared in the literature concerning the use of quantitative micro-imaging methods to pharmaceutically relevant research. Copyright © 2010 Elsevier B.V. All rights reserved.

  14. Virtualising the Quantitative Research Methods Course: An Island-Based Approach

    Science.gov (United States)

    Baglin, James; Reece, John; Baker, Jenalle

    2015-01-01

    Many recent improvements in pedagogical practice have been enabled by the rapid development of innovative technologies, particularly for teaching quantitative research methods and statistics. This study describes the design, implementation, and evaluation of a series of specialised computer laboratory sessions. The sessions combined the use of an…

  15. Quantitative method of X-ray diffraction phase analysis of building materials

    International Nuclear Information System (INIS)

    Czuba, J.; Dziedzic, A.

    1978-01-01

    Quantitative method of X-ray diffraction phase analysis of building materials, with use of internal standard, has been presented. The errors committed by determining the content of particular phases have been also given. (author)

  16. A method for the quantitative determination of crystalline phases by X-ray

    Science.gov (United States)

    Petzenhauser, I.; Jaeger, P.

    1988-01-01

    A mineral analysis method is described for rapid quantitative determination of crystalline substances in those cases in which the sample is present in pure form or in a mixture of known composition. With this method there is no need for prior chemical analysis.

  17. Critical Analysis of Strategies for Determining Rigor in Qualitative Inquiry.

    Science.gov (United States)

    Morse, Janice M

    2015-09-01

    Criteria for determining the trustworthiness of qualitative research were introduced by Guba and Lincoln in the 1980s when they replaced terminology for achieving rigor, reliability, validity, and generalizability with dependability, credibility, and transferability. Strategies for achieving trustworthiness were also introduced. This landmark contribution to qualitative research remains in use today, with only minor modifications in format. Despite the significance of this contribution over the past four decades, the strategies recommended to achieve trustworthiness have not been critically examined. Recommendations for where, why, and how to use these strategies have not been developed, and how well they achieve their intended goal has not been examined. We do not know, for example, what impact these strategies have on the completed research. In this article, I critique these strategies. I recommend that qualitative researchers return to the terminology of social sciences, using rigor, reliability, validity, and generalizability. I then make recommendations for the appropriate use of the strategies recommended to achieve rigor: prolonged engagement, persistent observation, and thick, rich description; inter-rater reliability, negative case analysis; peer review or debriefing; clarifying researcher bias; member checking; external audits; and triangulation. © The Author(s) 2015.

  18. VERIFICATION HPLC METHOD OF QUANTITATIVE DETERMINATION OF AMLODIPINE IN TABLETS

    Directory of Open Access Journals (Sweden)

    Khanin V. A

    2014-10-01

    Full Text Available Introduction. Amlodipine ((±-2-[(2-aminoetoksimethyl]-4-(2-chlorophenyl-1,4-dihydro-6-methyl-3,5-pyridine dicarboxylic acid 3-ethyl 5-methyl ester as besylate and small tally belongs to the group of selective long-acting calcium channel blockers, dihydropyridine derivatives. In clinical practice, as antianginal and antihypertensive agent for the treatment of cardiovascular diseases. It is produced in powder form, substance and finished dosage forms (tablets of 2.5, 5 and 10 mg. The scientific literature describes methods of quantitative determination of the drug by spectrophotometry – by his own light absorption and by reaction product with aloksan, chromatography techniques, kinetic-spectrophotometric method in substances and preparations and methods chromatomass spectrometry and stripping voltammetry. For the quantitative determination of amlodipine besylate British Pharmacopoeia and European Pharmacopoeia recommend the use of liquid chromatography method. In connection with the establishment of the second edition of SPhU and when it is comprised of articles on the finished product, we set out to analyze the characteristics of the validation of chromatographic quantitative determination of amlodipine besylate tablets and to verify the analytical procedure. Material & methods. In conducting research using substance amlodipine besylate series number AB0401013. Analysis subject pill “Amlodipine” series number 20113 manufacturer of “Pharmaceutical company “Zdorovye”. Analytical equipment used is: 2695 chromatograph with diode array detector 2996 firms Waters Corp. USA using column Nova-Pak C18 300 x 3,9 mm with a particle size of 4 μm, weight ER-182 company AND Japan, measuring vessel class A. Preparation of the test solution. To accurately sample powder tablets equivalent to 50 mg amlodipine, add 30 ml of methanol, shake for 30 minutes, dilute the solution to 50.0 ml with methanol and filtered. 5 ml of methanol solution adjusted to

  19. A Quantitative Analytical Method to Test for Salt Effects on Giant Unilamellar Vesicles

    DEFF Research Database (Denmark)

    Hadorn, Maik; Bönzli, Eva; Eggenberger Hotz, Peter

    2011-01-01

    preparation method with automatic haemocytometry. We found that this new quantitative screening method is highly reliable and consistent with previously reported results. Thus, this method may provide a significant methodological advance in analysis of effects on free-standing model membranes....

  20. Quantitative Analysis of Ductile Iron Microstructure – A Comparison of Selected Methods for Assessment

    Directory of Open Access Journals (Sweden)

    Mrzygłód B.

    2013-09-01

    Full Text Available Stereological description of dispersed microstructure is not an easy task and remains the subject of continuous research. In its practical aspect, a correct stereological description of this type of structure is essential for the analysis of processes of coagulation and spheroidisation, or for studies of relationships between structure and properties. One of the most frequently used methods for an estimation of the density Nv and size distribution of particles is the Scheil - Schwartz - Saltykov method. In this article, the authors present selected methods for quantitative assessment of ductile iron microstructure, i.e. the Scheil - Schwartz - Saltykov method, which allows a quantitative description of three-dimensional sets of solids using measurements and counts performed on two-dimensional cross-sections of these sets (microsections and quantitative description of three-dimensional sets of solids by X-ray computed microtomography, which is an interesting alternative for structural studies compared to traditional methods of microstructure imaging since, as a result, the analysis provides a three-dimensional imaging of microstructures examined.

  1. QUANTITATIVE EVALUATION METHOD OF ELEMENTS PRIORITY OF CARTOGRAPHIC GENERALIZATION BASED ON TAXI TRAJECTORY DATA

    Directory of Open Access Journals (Sweden)

    Z. Long

    2017-09-01

    Full Text Available Considering the lack of quantitative criteria for the selection of elements in cartographic generalization, this study divided the hotspot areas of passengers into parts at three levels, gave them different weights, and then classified the elements from the different hotspots. On this basis, a method was proposed to quantify the priority of elements selection. Subsequently, the quantitative priority of different cartographic elements was summarized based on this method. In cartographic generalization, the method can be preferred to select the significant elements and discard those that are relatively non-significant.

  2. An improved transmutation method for quantitative determination of the components in multicomponent overlapping chromatograms.

    Science.gov (United States)

    Shao, Xueguang; Yu, Zhengliang; Ma, Chaoxiong

    2004-06-01

    An improved method is proposed for the quantitative determination of multicomponent overlapping chromatograms based on a known transmutation method. To overcome the main limitation of the transmutation method caused by the oscillation generated in the transmutation process, two techniques--wavelet transform smoothing and the cubic spline interpolation for reducing data points--were adopted, and a new criterion was also developed. By using the proposed algorithm, the oscillation can be suppressed effectively, and quantitative determination of the components in both the simulated and experimental overlapping chromatograms is successfully obtained.

  3. Assessment of the Methodological Rigor of Case Studies in the Field of Management Accounting Published in Journals in Brazil

    Directory of Open Access Journals (Sweden)

    Kelly Cristina Mucio Marques

    2015-04-01

    Full Text Available This study aims to assess the methodological rigor of case studies in management accounting published in Brazilian journals. The study is descriptive. The data were collected using documentary research and content analysis, and 180 papers published from 2008 to 2012 in accounting journals rated as A2, B1, and B2 that were classified as case studies were selected. Based on the literature, we established a set of 15 criteria that we expected to be identified (either explicitly or implicitly in the case studies to classify those case studies as appropriate from the standpoint of methodological rigor. These criteria were partially met by the papers analyzed. The aspects less aligned with those proposed in the literature were the following: little emphasis on justifying the need to understand phenomena in context; lack of explanation of the reason for choosing the case study strategy; the predominant use of questions that do not enable deeper analysis; many studies based on only one source of evidence; little use of data and information triangulation; little emphasis on the data collection method; a high number of cases in which confusion between case study as a research strategy and as data collection method were detected; a low number of papers reporting the method of data analysis; few reports on a study's contributions; and a minority highlighting the issues requiring further research. In conclusion, the method used to apply case studies to management accounting must be improved because few studies showed rigorous application of the procedures that this strategy requires.

  4. RIGOROUS PHOTOGRAMMETRIC PROCESSING OF CHANG'E-1 AND CHANG'E-2 STEREO IMAGERY FOR LUNAR TOPOGRAPHIC MAPPING

    Directory of Open Access Journals (Sweden)

    K. Di

    2012-07-01

    Full Text Available Chang'E-1(CE-1 and Chang'E-2(CE-2 are the two lunar orbiters of China's lunar exploration program. Topographic mapping using CE-1 and CE-2 images is of great importance for scientific research as well as for preparation of landing and surface operation of Chang'E-3 lunar rover. In this research, we developed rigorous sensor models of CE-1 and CE-2 CCD cameras based on push-broom imaging principle with interior and exterior orientation parameters. Based on the rigorous sensor model, the 3D coordinate of a ground point in lunar body-fixed (LBF coordinate system can be calculated by space intersection from the image coordinates of con-jugate points in stereo images, and the image coordinates can be calculated from 3D coordinates by back-projection. Due to uncer-tainties of the orbit and the camera, the back-projected image points are different from the measured points. In order to reduce these inconsistencies and improve precision, we proposed two methods to refine the rigorous sensor model: 1 refining EOPs by correcting the attitude angle bias, 2 refining the interior orientation model by calibration of the relative position of the two linear CCD arrays. Experimental results show that the mean back-projection residuals of CE-1 images are reduced to better than 1/100 pixel by method 1 and the mean back-projection residuals of CE-2 images are reduced from over 20 pixels to 0.02 pixel by method 2. Consequently, high precision DEM (Digital Elevation Model and DOM (Digital Ortho Map are automatically generated.

  5. Integration of Qualitative and Quantitative Methods: Building and Interpreting Clusters from Grounded Theory and Discourse Analysis

    Directory of Open Access Journals (Sweden)

    Aldo Merlino

    2007-01-01

    Full Text Available Qualitative methods present a wide spectrum of application possibilities as well as opportunities for combining qualitative and quantitative methods. In the social sciences fruitful theoretical discussions and a great deal of empirical research have taken place. This article introduces an empirical investigation which demonstrates the logic of combining methodologies as well as the collection and interpretation, both sequential as simultaneous, of qualitative and quantitative data. Specifically, the investigation process will be described, beginning with a grounded theory methodology and its combination with the techniques of structural semiotics discourse analysis to generate—in a first phase—an instrument for quantitative measuring and to understand—in a second phase—clusters obtained by quantitative analysis. This work illustrates how qualitative methods allow for the comprehension of the discursive and behavioral elements under study, and how they function as support making sense of and giving meaning to quantitative data. URN: urn:nbn:de:0114-fqs0701219

  6. A method of quantitative prediction for sandstone type uranium deposit in Russia and its application

    International Nuclear Information System (INIS)

    Chang Shushuai; Jiang Minzhong; Li Xiaolu

    2008-01-01

    The paper presents the foundational principle of quantitative predication for sandstone type uranium deposits in Russia. Some key methods such as physical-mathematical model construction and deposits prediction are described. The method has been applied to deposits prediction in Dahongshan region of Chaoshui basin. It is concluded that the technique can fortify the method of quantitative predication for sandstone type uranium deposits, and it could be used as a new technique in China. (authors)

  7. Biological characteristics of crucian by quantitative inspection method

    Science.gov (United States)

    Chu, Mengqi

    2015-04-01

    Biological characteristics of crucian by quantitative inspection method Through quantitative inspection method , the biological characteristics of crucian was preliminary researched. Crucian , Belongs to Cypriniformes, Cyprinidae, Carassius auratus, is a kind of main plant-eating omnivorous fish,like Gregarious, selection and ranking. Crucian are widely distributed, perennial water all over the country all have production. Determine the indicators of crucian in the experiment, to understand the growth, reproduction situation of crucian in this area . Using the measured data (such as the scale length ,scale size and wheel diameter and so on) and related functional to calculate growth of crucian in any one year.According to the egg shape, color, weight ,etc to determine its maturity, with the mean egg diameter per 20 eggs and the number of eggs per 0.5 grams, to calculate the relative and absolute fecundity of the fish .Measured crucian were female puberty. Based on the relation between the scale diameter and length and the information, linear relationship between crucian scale diameter and length: y=1.530+3.0649. From the data, the fertility and is closely relative to the increase of age. The older, the more mature gonad development. The more amount of eggs. In addition, absolute fecundity increases with the pituitary gland.Through quantitative check crucian bait food intake by the object, reveals the main food, secondary foods, and chance food of crucian ,and understand that crucian degree of be fond of of all kinds of bait organisms.Fish fertility with weight gain, it has the characteristics of species and populations, and at the same tmes influenced by the age of the individual, body length, body weight, environmental conditions (especially the nutrition conditions), and breeding habits, spawning times factors and the size of the egg. After a series of studies of crucian biological character, provide the ecological basis for local crucian's feeding, breeding

  8. Quantitatively differentiating microstructural variations of skeletal muscle tissues by multispectral Mueller matrix imaging

    Science.gov (United States)

    Dong, Yang; He, Honghui; He, Chao; Ma, Hui

    2016-10-01

    Polarized light is sensitive to the microstructures of biological tissues and can be used to detect physiological changes. Meanwhile, spectral features of the scattered light can also provide abundant microstructural information of tissues. In this paper, we take the backscattering polarization Mueller matrix images of bovine skeletal muscle tissues during the 24-hour experimental time, and analyze their multispectral behavior using quantitative Mueller matrix parameters. In the processes of rigor mortis and proteolysis of muscle samples, multispectral frequency distribution histograms (FDHs) of the Mueller matrix elements can reveal rich qualitative structural information. In addition, we analyze the temporal variations of the sample using the multispectral Mueller matrix transformation (MMT) parameters. The experimental results indicate that the different stages of rigor mortis and proteolysis for bovine skeletal muscle samples can be judged by these MMT parameters. The results presented in this work show that combining with the multispectral technique, the FDHs and MMT parameters can characterize the microstructural variation features of skeletal muscle tissues. The techniques have the potential to be used as tools for quantitative assessment of meat qualities in food industry.

  9. The Relationship between Project-Based Learning and Rigor in STEM-Focused High Schools

    Science.gov (United States)

    Edmunds, Julie; Arshavsky, Nina; Glennie, Elizabeth; Charles, Karen; Rice, Olivia

    2016-01-01

    Project-based learning (PjBL) is an approach often favored in STEM classrooms, yet some studies have shown that teachers struggle to implement it with academic rigor. This paper explores the relationship between PjBL and rigor in the classrooms of ten STEM-oriented high schools. Utilizing three different data sources reflecting three different…

  10. Applicability and interpretation of fracture test methods for metals

    International Nuclear Information System (INIS)

    Langford, W.J.

    1978-05-01

    Fracture tests are conducted usually out of a conviction (sometimes only vaguely defined) that they will guarantee a certain level of protecton from metal failure. Qualitative tests, such as the Charpy V-notch, produce results which cannot be rigorously related to a measure of fracture tolerance: rather, they indicate metal quality so that fracture tolerance may be inferred. Quantitative tests on the other hand provide parameters which may be used directly in equations to determine the likelihood of fracture. Both types of tests have limitations which should be understood: the paper tries to provide guidance on the relative merits of either approach for a particular purpose, and gives an insight into near-future test methods which will extend the range of usefullness of quantitative tests. (author)

  11. Rigorous approximation of stationary measures and convergence to equilibrium for iterated function systems

    International Nuclear Information System (INIS)

    Galatolo, Stefano; Monge, Maurizio; Nisoli, Isaia

    2016-01-01

    We study the problem of the rigorous computation of the stationary measure and of the rate of convergence to equilibrium of an iterated function system described by a stochastic mixture of two or more dynamical systems that are either all uniformly expanding on the interval, either all contracting. In the expanding case, the associated transfer operators satisfy a Lasota–Yorke inequality, we show how to compute a rigorous approximations of the stationary measure in the L "1 norm and an estimate for the rate of convergence. The rigorous computation requires a computer-aided proof of the contraction of the transfer operators for the maps, and we show that this property propagates to the transfer operators of the IFS. In the contracting case we perform a rigorous approximation of the stationary measure in the Wasserstein–Kantorovich distance and rate of convergence, using the same functional analytic approach. We show that a finite computation can produce a realistic computation of all contraction rates for the whole parameter space. We conclude with a description of the implementation and numerical experiments. (paper)

  12. A collimator optimization method for quantitative imaging: application to Y-90 bremsstrahlung SPECT.

    Science.gov (United States)

    Rong, Xing; Frey, Eric C

    2013-08-01

    Post-therapy quantitative 90Y bremsstrahlung single photon emission computed tomography (SPECT) has shown great potential to provide reliable activity estimates, which are essential for dose verification. Typically 90Y imaging is performed with high- or medium-energy collimators. However, the energy spectrum of 90Y bremsstrahlung photons is substantially different than typical for these collimators. In addition, dosimetry requires quantitative images, and collimators are not typically optimized for such tasks. Optimizing a collimator for 90Y imaging is both novel and potentially important. Conventional optimization methods are not appropriate for 90Y bremsstrahlung photons, which have a continuous and broad energy distribution. In this work, the authors developed a parallel-hole collimator optimization method for quantitative tasks that is particularly applicable to radionuclides with complex emission energy spectra. The authors applied the proposed method to develop an optimal collimator for quantitative 90Y bremsstrahlung SPECT in the context of microsphere radioembolization. To account for the effects of the collimator on both the bias and the variance of the activity estimates, the authors used the root mean squared error (RMSE) of the volume of interest activity estimates as the figure of merit (FOM). In the FOM, the bias due to the null space of the image formation process was taken in account. The RMSE was weighted by the inverse mass to reflect the application to dosimetry; for a different application, more relevant weighting could easily be adopted. The authors proposed a parameterization for the collimator that facilitates the incorporation of the important factors (geometric sensitivity, geometric resolution, and septal penetration fraction) determining collimator performance, while keeping the number of free parameters describing the collimator small (i.e., two parameters). To make the optimization results for quantitative 90Y bremsstrahlung SPECT more

  13. Sustainability appraisal. Quantitative methods and mathematical techniques for environmental performance evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Erechtchoukova, Marina G.; Khaiter, Peter A. [York Univ., Toronto, ON (Canada). School of Information Technology; Golinska, Paulina (eds.) [Poznan Univ. of Technology (Poland)

    2013-06-01

    The book will present original research papers on the quantitative methods and techniques for the evaluation of the sustainability of business operations and organizations' overall environmental performance. The book contributions will describe modern methods and approaches applicable to the multi-faceted problem of sustainability appraisal and will help to fulfil generic frameworks presented in the literature with the specific quantitative techniques so needed in practice. The scope of the book is interdisciplinary in nature, making it of interest to environmental researchers, business managers and process analysts, information management professionals and environmental decision makers, who will find valuable sources of information for their work-related activities. Each chapter will provide sufficient background information, a description of problems, and results, making the book useful for a wider audience. Additional software support is not required. One of the most important issues in developing sustainable management strategies and incorporating ecodesigns in production, manufacturing and operations management is the assessment of the sustainability of business operations and organizations' overall environmental performance. The book presents the results of recent studies on sustainability assessment. It provides a solid reference for researchers in academia and industrial practitioners on the state-of-the-art in sustainability appraisal including the development and application of sustainability indices, quantitative methods, models and frameworks for the evaluation of current and future welfare outcomes, recommendations on data collection and processing for the evaluation of organizations' environmental performance, and eco-efficiency approaches leading to business process re-engineering.

  14. Quantitative determination and validation of octreotide acetate using 1 H-NMR spectroscopy with internal standard method.

    Science.gov (United States)

    Yu, Chen; Zhang, Qian; Xu, Peng-Yao; Bai, Yin; Shen, Wen-Bin; Di, Bin; Su, Meng-Xiang

    2018-01-01

    Quantitative nuclear magnetic resonance (qNMR) is a well-established technique in quantitative analysis. We presented a validated 1 H-qNMR method for assay of octreotide acetate, a kind of cyclic octopeptide. Deuterium oxide was used to remove the undesired exchangeable peaks, which was referred to as proton exchange, in order to make the quantitative signals isolated in the crowded spectrum of the peptide and ensure precise quantitative analysis. Gemcitabine hydrochloride was chosen as the suitable internal standard. Experimental conditions, including relaxation delay time, the numbers of scans, and pulse angle, were optimized first. Then method validation was carried out in terms of selectivity, stability, linearity, precision, and robustness. The assay result was compared with that by means of high performance liquid chromatography, which is provided by Chinese Pharmacopoeia. The statistical F test, Student's t test, and nonparametric test at 95% confidence level indicate that there was no significant difference between these two methods. qNMR is a simple and accurate quantitative tool with no need for specific corresponding reference standards. It has the potential of the quantitative analysis of other peptide drugs and standardization of the corresponding reference standards. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Quantitative analysis of γ-oryzanol content in cold pressed rice bran oil by TLC-image analysis method.

    Science.gov (United States)

    Sakunpak, Apirak; Suksaeree, Jirapornchai; Monton, Chaowalit; Pathompak, Pathamaporn; Kraisintu, Krisana

    2014-02-01

    To develop and validate an image analysis method for quantitative analysis of γ-oryzanol in cold pressed rice bran oil. TLC-densitometric and TLC-image analysis methods were developed, validated, and used for quantitative analysis of γ-oryzanol in cold pressed rice bran oil. The results obtained by these two different quantification methods were compared by paired t-test. Both assays provided good linearity, accuracy, reproducibility and selectivity for determination of γ-oryzanol. The TLC-densitometric and TLC-image analysis methods provided a similar reproducibility, accuracy and selectivity for the quantitative determination of γ-oryzanol in cold pressed rice bran oil. A statistical comparison of the quantitative determinations of γ-oryzanol in samples did not show any statistically significant difference between TLC-densitometric and TLC-image analysis methods. As both methods were found to be equal, they therefore can be used for the determination of γ-oryzanol in cold pressed rice bran oil.

  16. Reliability of a semi-quantitative method for dermal exposure assessment (DREAM)

    NARCIS (Netherlands)

    Wendel de Joode, B. van; Hemmen, J.J. van; Meijster, T.; Major, V.; London, L.; Kromhout, H.

    2005-01-01

    Valid and reliable semi-quantitative dermal exposure assessment methods for epidemiological research and for occupational hygiene practice, applicable for different chemical agents, are practically nonexistent. The aim of this study was to assess the reliability of a recently developed

  17. Informatics methods to enable sharing of quantitative imaging research data.

    Science.gov (United States)

    Levy, Mia A; Freymann, John B; Kirby, Justin S; Fedorov, Andriy; Fennessy, Fiona M; Eschrich, Steven A; Berglund, Anders E; Fenstermacher, David A; Tan, Yongqiang; Guo, Xiaotao; Casavant, Thomas L; Brown, Bartley J; Braun, Terry A; Dekker, Andre; Roelofs, Erik; Mountz, James M; Boada, Fernando; Laymon, Charles; Oborski, Matt; Rubin, Daniel L

    2012-11-01

    The National Cancer Institute Quantitative Research Network (QIN) is a collaborative research network whose goal is to share data, algorithms and research tools to accelerate quantitative imaging research. A challenge is the variability in tools and analysis platforms used in quantitative imaging. Our goal was to understand the extent of this variation and to develop an approach to enable sharing data and to promote reuse of quantitative imaging data in the community. We performed a survey of the current tools in use by the QIN member sites for representation and storage of their QIN research data including images, image meta-data and clinical data. We identified existing systems and standards for data sharing and their gaps for the QIN use case. We then proposed a system architecture to enable data sharing and collaborative experimentation within the QIN. There are a variety of tools currently used by each QIN institution. We developed a general information system architecture to support the QIN goals. We also describe the remaining architecture gaps we are developing to enable members to share research images and image meta-data across the network. As a research network, the QIN will stimulate quantitative imaging research by pooling data, algorithms and research tools. However, there are gaps in current functional requirements that will need to be met by future informatics development. Special attention must be given to the technical requirements needed to translate these methods into the clinical research workflow to enable validation and qualification of these novel imaging biomarkers. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Study of the quality characteristics in cold-smoked salmon (Salmo salar) originating from pre- or post-rigor raw material.

    Science.gov (United States)

    Birkeland, S; Akse, L

    2010-01-01

    Improved slaughtering procedures in the salmon industry have caused a delayed onset of rigor mortis and, thus, a potential for pre-rigor secondary processing. The aim of this study was to investigate the effect of rigor status at time of processing on quality traits color, texture, sensory, microbiological, in injection salted, and cold-smoked Atlantic salmon (Salmo salar). Injection of pre-rigor fillets caused a significant (Prigor processed fillets; however, post-rigor (1477 ± 38 g) fillets had a significant (P>0.05) higher fracturability than pre-rigor fillets (1369 ± 71 g). Pre-rigor fillets were significantly (Prigor fillets (37.8 ± 0.8) and had significantly lower (Prigor processed fillets. This study showed that similar quality characteristics can be obtained in cold-smoked products processed either pre- or post-rigor when using suitable injection salting protocols and smoking techniques. © 2010 Institute of Food Technologists®

  19. Ratio of slopes method for quantitative analysis in ceramic bodies

    International Nuclear Information System (INIS)

    Zainal Arifin Ahmad; Ahmad Fauzi Mohd Noor; Radzali Othman; Messer, P.F.

    1996-01-01

    A quantitative x-ray diffraction analysis technique developed at University of Sheffield was adopted, rather than the previously widely used internal standard method, to determine the amount of the phases present in a reformulated whiteware porcelain and a BaTiO sub 3 electrochemical material. This method, although still employs an internal standard, was found to be very easy and accurate. The required weight fraction of a phase in the mixture to be analysed is determined from the ratio of slopes of two linear plots, designated as the analysis and reference lines, passing through their origins using the least squares method

  20. Single-case synthesis tools II: Comparing quantitative outcome measures.

    Science.gov (United States)

    Zimmerman, Kathleen N; Pustejovsky, James E; Ledford, Jennifer R; Barton, Erin E; Severini, Katherine E; Lloyd, Blair P

    2018-03-07

    Varying methods for evaluating the outcomes of single case research designs (SCD) are currently used in reviews and meta-analyses of interventions. Quantitative effect size measures are often presented alongside visual analysis conclusions. Six measures across two classes-overlap measures (percentage non-overlapping data, improvement rate difference, and Tau) and parametric within-case effect sizes (standardized mean difference and log response ratio [increasing and decreasing])-were compared to determine if choice of synthesis method within and across classes impacts conclusions regarding effectiveness. The effectiveness of sensory-based interventions (SBI), a commonly used class of treatments for young children, was evaluated. Separately from evaluations of rigor and quality, authors evaluated behavior change between baseline and SBI conditions. SBI were unlikely to result in positive behavior change across all measures except IRD. However, subgroup analyses resulted in variable conclusions, indicating that the choice of measures for SCD meta-analyses can impact conclusions. Suggestions for using the log response ratio in SCD meta-analyses and considerations for understanding variability in SCD meta-analysis conclusions are discussed. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. From everyday communicative figurations to rigorous audience news repertoires

    DEFF Research Database (Denmark)

    Kobbernagel, Christian; Schrøder, Kim Christian

    2016-01-01

    In the last couple of decades there has been an unprecedented explosion of news media platforms and formats, as a succession of digital and social media have joined the ranks of legacy media. We live in a ‘hybrid media system’ (Chadwick, 2013), in which people build their cross-media news...... repertoires from the ensemble of old and new media available. This article presents an innovative mixed-method approach with considerable explanatory power to the exploration of patterns of news media consumption. This approach tailors Q-methodology in the direction of a qualitative study of news consumption......, in which a card sorting exercise serves to translate the participants’ news media preferences into a form that enables the researcher to undertake a rigorous factor-analytical construction of their news consumption repertoires. This interpretive, factor-analytical procedure, which results in the building...

  2. Proteus mirabilis biofilm - qualitative and quantitative colorimetric methods-based evaluation.

    Science.gov (United States)

    Kwiecinska-Piróg, Joanna; Bogiel, Tomasz; Skowron, Krzysztof; Wieckowska, Ewa; Gospodarek, Eugenia

    2014-01-01

    Proteus mirabilis strains ability to form biofilm is a current topic of a number of research worldwide. In this study the biofilm formation of P. mirabilis strains derived from urine of the catheterized and non-catheterized patients has been investigated. A total number of 39 P. mirabilis strains isolated from the urine samples of the patients of dr Antoni Jurasz University Hospital No. 1 in Bydgoszcz clinics between 2011 and 2012 was used. Biofilm formation was evaluated using two independent quantitative and qualitative methods with TTC (2,3,5-triphenyl-tetrazolium chloride) and CV (crystal violet) application. The obtained results confirmed biofilm formation by all the examined strains, except quantitative method with TTC, in which 7.7% of the strains did not have this ability. It was shown that P. mirabilis rods have the ability to form biofilm on the surfaces of both biomaterials applied, polystyrene and polyvinyl chloride (Nelaton catheters). The differences in ability to form biofilm observed between P. mirabilis strains derived from the urine of the catheterized and non-catheterized patients were not statistically significant.

  3. Proteus mirabilis biofilm - Qualitative and quantitative colorimetric methods-based evaluation

    Directory of Open Access Journals (Sweden)

    Joanna Kwiecinska-Piróg

    2014-12-01

    Full Text Available Proteus mirabilis strains ability to form biofilm is a current topic of a number of research worldwide. In this study the biofilm formation of P. mirabilis strains derived from urine of the catheterized and non-catheterized patients has been investigated. A total number of 39 P. mirabilis strains isolated from the urine samples of the patients of dr Antoni Jurasz University Hospital No. 1 in Bydgoszcz clinics between 2011 and 2012 was used. Biofilm formation was evaluated using two independent quantitative and qualitative methods with TTC (2,3,5-triphenyl-tetrazolium chloride and CV (crystal violet application. The obtained results confirmed biofilm formation by all the examined strains, except quantitative method with TTC, in which 7.7% of the strains did not have this ability. It was shown that P. mirabilis rods have the ability to form biofilm on the surfaces of both biomaterials applied, polystyrene and polyvinyl chloride (Nelaton catheters. The differences in ability to form biofilm observed between P. mirabilis strains derived from the urine of the catheterized and non-catheterized patients were not statistically significant.

  4. Quantitative Methods in Supply Chain Management Models and Algorithms

    CERN Document Server

    Christou, Ioannis T

    2012-01-01

    Quantitative Methods in Supply Chain Management presents some of the most important methods and tools available for modeling and solving problems arising in the context of supply chain management. In the context of this book, “solving problems” usually means designing efficient algorithms for obtaining high-quality solutions. The first chapter is an extensive optimization review covering continuous unconstrained and constrained linear and nonlinear optimization algorithms, as well as dynamic programming and discrete optimization exact methods and heuristics. The second chapter presents time-series forecasting methods together with prediction market techniques for demand forecasting of new products and services. The third chapter details models and algorithms for planning and scheduling with an emphasis on production planning and personnel scheduling. The fourth chapter presents deterministic and stochastic models for inventory control with a detailed analysis on periodic review systems and algorithmic dev...

  5. Genomic similarity and kernel methods I: advancements by building on mathematical and statistical foundations.

    Science.gov (United States)

    Schaid, Daniel J

    2010-01-01

    Measures of genomic similarity are the basis of many statistical analytic methods. We review the mathematical and statistical basis of similarity methods, particularly based on kernel methods. A kernel function converts information for a pair of subjects to a quantitative value representing either similarity (larger values meaning more similar) or distance (smaller values meaning more similar), with the requirement that it must create a positive semidefinite matrix when applied to all pairs of subjects. This review emphasizes the wide range of statistical methods and software that can be used when similarity is based on kernel methods, such as nonparametric regression, linear mixed models and generalized linear mixed models, hierarchical models, score statistics, and support vector machines. The mathematical rigor for these methods is summarized, as is the mathematical framework for making kernels. This review provides a framework to move from intuitive and heuristic approaches to define genomic similarities to more rigorous methods that can take advantage of powerful statistical modeling and existing software. A companion paper reviews novel approaches to creating kernels that might be useful for genomic analyses, providing insights with examples [1]. Copyright © 2010 S. Karger AG, Basel.

  6. Conductance method for quantitative determination of Photobacterium phosphoreum in fish products

    DEFF Research Database (Denmark)

    Dalgaard, Paw; Mejlholm, Ole; Huss, Hans Henrik

    1996-01-01

    This paper presents the development of a sensitive and selective conductance method for quantitative determination of Photobacterium phosphoreum in fresh fish. A calibration curve with a correlation coefficient of -0.981 was established from conductance detection times (DT) for estimation of cell...

  7. Upgrading geometry conceptual understanding and strategic competence through implementing rigorous mathematical thinking (RMT)

    Science.gov (United States)

    Nugraheni, Z.; Budiyono, B.; Slamet, I.

    2018-03-01

    To reach higher order thinking skill, needed to be mastered the conceptual understanding and strategic competence as they are two basic parts of high order thinking skill (HOTS). RMT is a unique realization of the cognitive conceptual construction approach based on Feurstein with his theory of Mediated Learning Experience (MLE) and Vygotsky’s sociocultural theory. This was quasi-experimental research which compared the experimental class that was given Rigorous Mathematical Thinking (RMT) as learning method and the control class that was given Direct Learning (DL) as the conventional learning activity. This study examined whether there was different effect of two learning model toward conceptual understanding and strategic competence of Junior High School Students. The data was analyzed by using Multivariate Analysis of Variance (MANOVA) and obtained a significant difference between experimental and control class when considered jointly on the mathematics conceptual understanding and strategic competence (shown by Wilk’s Λ = 0.84). Further, by independent t-test is known that there was significant difference between two classes both on mathematical conceptual understanding and strategic competence. By this result is known that Rigorous Mathematical Thinking (RMT) had positive impact toward Mathematics conceptual understanding and strategic competence.

  8. Bringing scientific rigor to community-developed programs in Hong Kong

    Directory of Open Access Journals (Sweden)

    Fabrizio Cecilia S

    2012-12-01

    Full Text Available Abstract Background This paper describes efforts to generate evidence for community-developed programs to enhance family relationships in the Chinese culture of Hong Kong, within the framework of community-based participatory research (CBPR. Methods The CBPR framework was applied to help maximize the development of the intervention and the public health impact of the studies, while enhancing the capabilities of the social service sector partners. Results Four academic-community research teams explored the process of designing and implementing randomized controlled trials in the community. In addition to the expected cultural barriers between teams of academics and community practitioners, with their different outlooks, concerns and languages, the team navigated issues in utilizing the principles of CBPR unique to this Chinese culture. Eventually the team developed tools for adaptation, such as an emphasis on building the relationship while respecting role delineation and an iterative process of defining the non-negotiable parameters of research design while maintaining scientific rigor. Lessons learned include the risk of underemphasizing the size of the operational and skills shift between usual agency practices and research studies, the importance of minimizing non-negotiable parameters in implementing rigorous research designs in the community, and the need to view community capacity enhancement as a long term process. Conclusions The four pilot studies under the FAMILY Project demonstrated that nuanced design adaptations, such as wait list controls and shorter assessments, better served the needs of the community and led to the successful development and vigorous evaluation of a series of preventive, family-oriented interventions in the Chinese culture of Hong Kong.

  9. Study on methods of quantitative analysis of the biological thin samples in EM X-ray microanalysis

    International Nuclear Information System (INIS)

    Zhang Detian; Zhang Xuemin; He Kun; Yang Yi; Zhang Sa; Wang Baozhen

    2000-01-01

    Objective: To study the methods of quantitative analysis of the biological thin samples. Methods: Hall theory was used to study the qualitative analysis, background subtraction, peel off overlap peaks; external radiation and aberrance of spectra. Results: The results of reliable qualitative analysis and precise quantitative analysis were achieved. Conclusion: The methods for analysis of the biological thin samples in EM X-ray microanalysis can be used in biomedical research

  10. MASTERS OF ANALYTICAL TRADECRAFT: CERTIFYING THE STANDARDS AND ANALYTIC RIGOR OF INTELLIGENCE PRODUCTS

    Science.gov (United States)

    2016-04-01

    AU/ACSC/2016 AIR COMMAND AND STAFF COLLEGE AIR UNIVERSITY MASTERS OF ANALYTICAL TRADECRAFT: CERTIFYING THE STANDARDS AND ANALYTIC RIGOR OF...establishing unit level certified Masters of Analytic Tradecraft (MAT) analysts to be trained and entrusted to evaluate and rate the standards and...cues) ideally should meet or exceed effective rigor (based on analytical process).4 To accomplish this, decision makers should not be left to their

  11. General Methods for Evolutionary Quantitative Genetic Inference from Generalized Mixed Models.

    Science.gov (United States)

    de Villemereuil, Pierre; Schielzeth, Holger; Nakagawa, Shinichi; Morrissey, Michael

    2016-11-01

    Methods for inference and interpretation of evolutionary quantitative genetic parameters, and for prediction of the response to selection, are best developed for traits with normal distributions. Many traits of evolutionary interest, including many life history and behavioral traits, have inherently nonnormal distributions. The generalized linear mixed model (GLMM) framework has become a widely used tool for estimating quantitative genetic parameters for nonnormal traits. However, whereas GLMMs provide inference on a statistically convenient latent scale, it is often desirable to express quantitative genetic parameters on the scale upon which traits are measured. The parameters of fitted GLMMs, despite being on a latent scale, fully determine all quantities of potential interest on the scale on which traits are expressed. We provide expressions for deriving each of such quantities, including population means, phenotypic (co)variances, variance components including additive genetic (co)variances, and parameters such as heritability. We demonstrate that fixed effects have a strong impact on those parameters and show how to deal with this by averaging or integrating over fixed effects. The expressions require integration of quantities determined by the link function, over distributions of latent values. In general cases, the required integrals must be solved numerically, but efficient methods are available and we provide an implementation in an R package, QGglmm. We show that known formulas for quantities such as heritability of traits with binomial and Poisson distributions are special cases of our expressions. Additionally, we show how fitted GLMM can be incorporated into existing methods for predicting evolutionary trajectories. We demonstrate the accuracy of the resulting method for evolutionary prediction by simulation and apply our approach to data from a wild pedigreed vertebrate population. Copyright © 2016 de Villemereuil et al.

  12. Domestication of smartphones and mobile applications: A quantitative mixed-method study

    NARCIS (Netherlands)

    de Reuver, G.A.; Nikou, S; Bouwman, W.A.G.A.

    2016-01-01

    Smartphones are finding their way into our daily lives. This paper examines the domestication of smartphones by looking at how the way we use mobile applications affects our everyday routines. Data is collected through an innovative quantitative mixed-method approach, combining log data from

  13. A method of quantitative risk assessment for transmission pipeline carrying natural gas

    International Nuclear Information System (INIS)

    Jo, Young-Do; Ahn, Bum Jong

    2005-01-01

    Regulatory authorities in many countries are moving away from prescriptive approaches for keeping natural gas pipelines safe. As an alternative, risk management based on a quantitative assessment is being considered to improve the level of safety. This paper focuses on the development of a simplified method for the quantitative risk assessment for natural gas pipelines and introduces parameters of fatal length and cumulative fatal length. The fatal length is defined as the integrated fatality along the pipeline associated with hypothetical accidents. The cumulative fatal length is defined as the section of pipeline in which an accident leads to N or more fatalities. These parameters can be estimated easily by using the information of pipeline geometry and population density of a Geographic Information Systems (GIS). To demonstrate the proposed method, individual and societal risks for a sample pipeline have been estimated from the historical data of European Gas Pipeline Incident Data Group and BG Transco. With currently acceptable criteria taken into account for individual risk, the minimum proximity of the pipeline to occupied buildings is approximately proportional to the square root of the operating pressure of the pipeline. The proposed method of quantitative risk assessment may be useful for risk management during the planning and building stages of a new pipeline, and modification of a buried pipeline

  14. Quantitative electromechanical impedance method for nondestructive testing based on a piezoelectric bimorph cantilever

    International Nuclear Information System (INIS)

    Fu, Ji; Tan, Chi; Li, Faxin

    2015-01-01

    The electromechanical impedance (EMI) method, which holds great promise in structural health monitoring (SHM), is usually treated as a qualitative method. In this work, we proposed a quantitative EMI method based on a piezoelectric bimorph cantilever using the sample’s local contact stiffness (LCS) as the identification parameter for nondestructive testing (NDT). Firstly, the equivalent circuit of the contact vibration system was established and the analytical relationship between the cantilever’s contact resonance frequency and the LCS was obtained. As the LCS is sensitive to typical defects such as voids and delamination, the proposed EMI method can then be used for NDT. To verify the equivalent circuit model, two piezoelectric bimorph cantilevers were fabricated and their free resonance frequencies were measured and compared with theoretical predictions. It was found that the stiff cantilever’s EMI can be well predicted by the equivalent circuit model while the soft cantilever’s cannot. Then, both cantilevers were assembled into a homemade NDT system using a three-axis motorized stage for LCS scanning. Testing results on a specimen with a prefabricated defect showed that the defect could be clearly reproduced in the LCS image, indicating the validity of the quantitative EMI method for NDT. It was found that the single-frequency mode of the EMI method can also be used for NDT, which is faster but not quantitative. Finally, several issues relating to the practical application of the NDT method were discussed. The proposed EMI-based NDT method offers a simple and rapid solution for damage evaluation in engineering structures and may also shed some light on EMI-based SHM. (paper)

  15. Location of airports - selected quantitative methods

    Directory of Open Access Journals (Sweden)

    Agnieszka Merkisz-Guranowska

    2016-09-01

    Full Text Available Background: The role of air transport in  the economic development of a country and its regions cannot be overestimated. The decision concerning an airport's location must be in line with the expectations of all the stakeholders involved. This article deals with the issues related to the choice of  sites where airports should be located. Methods: Two main quantitative approaches related to the issue of airport location are presented in this article, i.e. the question of optimizing such a choice and the issue of selecting the location from a predefined set. The former involves mathematical programming and formulating the problem as an optimization task, the latter, however, involves ranking the possible variations. Due to various methodological backgrounds, the authors present the advantages and disadvantages of both approaches and point to the one which currently has its own practical application. Results: Based on real-life examples, the authors present a multi-stage procedure, which renders it possible to solve the problem of airport location. Conclusions: Based on the overview of literature of the subject, the authors point to three types of approach to the issue of airport location which could enable further development of currently applied methods.

  16. Research design: qualitative, quantitative and mixed methods approaches Research design: qualitative, quantitative and mixed methods approaches Creswell John W Sage 320 £29 0761924426 0761924426 [Formula: see text].

    Science.gov (United States)

    2004-09-01

    The second edition of Creswell's book has been significantly revised and updated. The author clearly sets out three approaches to research: quantitative, qualitative and mixed methods. As someone who has used mixed methods in my research, it is refreshing to read a textbook that addresses this. The differences between the approaches are clearly identified and a rationale for using each methodological stance provided.

  17. Quantitative bioanalytical and analytical method development of dibenzazepine derivative, carbamazepine: A review ☆

    OpenAIRE

    Datar, Prasanna A.

    2015-01-01

    Bioanalytical methods are widely used for quantitative estimation of drugs and their metabolites in physiological matrices. These methods could be applied to studies in areas of human clinical pharmacology and toxicology. The major bioanalytical services are method development, method validation and sample analysis (method application). Various methods such as GC, LC–MS/MS, HPLC, HPTLC, micellar electrokinetic chromatography, and UFLC have been used in laboratories for the qualitative and qua...

  18. Quantitative Evaluation of Heavy Duty Machine Tools Remanufacturing Based on Modified Catastrophe Progression Method

    Science.gov (United States)

    shunhe, Li; jianhua, Rao; lin, Gui; weimin, Zhang; degang, Liu

    2017-11-01

    The result of remanufacturing evaluation is the basis for judging whether the heavy duty machine tool can remanufacture in the EOL stage of the machine tool lifecycle management.The objectivity and accuracy of evaluation is the key to the evaluation method.In this paper, the catastrophe progression method is introduced into the quantitative evaluation of heavy duty machine tools’ remanufacturing,and the results are modified by the comprehensive adjustment method,which makes the evaluation results accord with the standard of human conventional thinking.Using the catastrophe progression method to establish the heavy duty machine tools’ quantitative evaluation model,to evaluate the retired TK6916 type CNC floor milling-boring machine’s remanufacturing.The evaluation process is simple,high quantification,the result is objective.

  19. [Development and validation of event-specific quantitative PCR method for genetically modified maize LY038].

    Science.gov (United States)

    Mano, Junichi; Masubuchi, Tomoko; Hatano, Shuko; Futo, Satoshi; Koiwa, Tomohiro; Minegishi, Yasutaka; Noguchi, Akio; Kondo, Kazunari; Akiyama, Hiroshi; Teshima, Reiko; Kurashima, Takeyo; Takabatake, Reona; Kitta, Kazumi

    2013-01-01

    In this article, we report a novel real-time PCR-based analytical method for quantitation of the GM maize event LY038. We designed LY038-specific and maize endogenous reference DNA-specific PCR amplifications. After confirming the specificity and linearity of the LY038-specific PCR amplification, we determined the conversion factor required to calculate the weight-based content of GM organism (GMO) in a multilaboratory evaluation. Finally, in order to validate the developed method, an interlaboratory collaborative trial according to the internationally harmonized guidelines was performed with blind DNA samples containing LY038 at the mixing levels of 0, 0.5, 1.0, 5.0 and 10.0%. The precision of the method was evaluated as the RSD of reproducibility (RSDR), and the values obtained were all less than 25%. The limit of quantitation of the method was judged to be 0.5% based on the definition of ISO 24276 guideline. The results from the collaborative trial suggested that the developed quantitative method would be suitable for practical testing of LY038 maize.

  20. Quantitative data analysis methods for 3D microstructure characterization of Solid Oxide Cells

    DEFF Research Database (Denmark)

    Jørgensen, Peter Stanley

    through percolating networks and reaction rates at the triple phase boundaries. Quantitative analysis of microstructure is thus important both in research and development of optimal microstructure design and fabrication. Three dimensional microstructure characterization in particular holds great promise...... for gaining further fundamental understanding of how microstructure affects performance. In this work, methods for automatic 3D characterization of microstructure are studied: from the acquisition of 3D image data by focused ion beam tomography to the extraction of quantitative measures that characterize...... the microstructure. The methods are exemplied by the analysis of Ni-YSZ and LSC-CGO electrode samples. Automatic methods for preprocessing the raw 3D image data are developed. The preprocessing steps correct for errors introduced by the image acquisition by the focused ion beam serial sectioning. Alignment...

  1. A comparison of visual and quantitative methods to identify interstitial lung abnormalities

    OpenAIRE

    Kliment, Corrine R.; Araki, Tetsuro; Doyle, Tracy J.; Gao, Wei; Dupuis, Jos?e; Latourelle, Jeanne C.; Zazueta, Oscar E.; Fernandez, Isis E.; Nishino, Mizuki; Okajima, Yuka; Ross, James C.; Est?par, Ra?l San Jos?; Diaz, Alejandro A.; Lederer, David J.; Schwartz, David A.

    2015-01-01

    Background: Evidence suggests that individuals with interstitial lung abnormalities (ILA) on a chest computed tomogram (CT) may have an increased risk to develop a clinically significant interstitial lung disease (ILD). Although methods used to identify individuals with ILA on chest CT have included both automated quantitative and qualitative visual inspection methods, there has been not direct comparison between these two methods. To investigate this relationship, we created lung density met...

  2. Wavelength Selection Method Based on Differential Evolution for Precise Quantitative Analysis Using Terahertz Time-Domain Spectroscopy.

    Science.gov (United States)

    Li, Zhi; Chen, Weidong; Lian, Feiyu; Ge, Hongyi; Guan, Aihong

    2017-12-01

    Quantitative analysis of component mixtures is an important application of terahertz time-domain spectroscopy (THz-TDS) and has attracted broad interest in recent research. Although the accuracy of quantitative analysis using THz-TDS is affected by a host of factors, wavelength selection from the sample's THz absorption spectrum is the most crucial component. The raw spectrum consists of signals from the sample and scattering and other random disturbances that can critically influence the quantitative accuracy. For precise quantitative analysis using THz-TDS, the signal from the sample needs to be retained while the scattering and other noise sources are eliminated. In this paper, a novel wavelength selection method based on differential evolution (DE) is investigated. By performing quantitative experiments on a series of binary amino acid mixtures using THz-TDS, we demonstrate the efficacy of the DE-based wavelength selection method, which yields an error rate below 5%.

  3. Examining Stress in Graduate Assistants: Combining Qualitative and Quantitative Survey Methods

    Science.gov (United States)

    Mazzola, Joseph J.; Walker, Erin J.; Shockley, Kristen M.; Spector, Paul E.

    2011-01-01

    The aim of this study was to employ qualitative and quantitative survey methods in a concurrent mixed model design to assess stressors and strains in graduate assistants. The stressors most frequently reported qualitatively were work overload, interpersonal conflict, and organizational constraints; the most frequently reported psychological…

  4. The Use of Quantitative and Qualitative Methods in the Analysis of Academic Achievement among Undergraduates in Jamaica

    Science.gov (United States)

    McLaren, Ingrid Ann Marie

    2012-01-01

    This paper describes a study which uses quantitative and qualitative methods in determining the relationship between academic, institutional and psychological variables and degree performance for a sample of Jamaican undergraduate students. Quantitative methods, traditionally associated with the positivist paradigm, and involving the counting and…

  5. A REVIEW OF QUANTITATIVE METHODS FOR STUDIES OF MINERAL-CONTENT OF INTRAORAL INCIPIENT CARIES LESIONS

    NARCIS (Netherlands)

    TENBOSCH, JJ; ANGMARMANSSON, B

    Modern prospective caries studies require the measurement of small changes in tooth mineral content. Quantitative measurements of changes in mineral content in a single caries lesion is desirable. Quantitative methods can be either destructive or non-destructive. The latter type permits longitudinal

  6. Electrocardiogram artifact caused by rigors mimicking narrow complex tachycardia: a case report.

    Science.gov (United States)

    Matthias, Anne Thushara; Indrakumar, Jegarajah

    2014-02-04

    The electrocardiogram (ECG) is useful in the diagnosis of cardiac and non-cardiac conditions. Rigors due to shivering can cause electrocardiogram artifacts mimicking various cardiac rhythm abnormalities. We describe an 80-year-old Sri Lankan man with an abnormal electrocardiogram mimicking narrow complex tachycardia during the immediate post-operative period. Electrocardiogram changes caused by muscle tremor during rigors could mimic a narrow complex tachycardia. Identification of muscle tremor as a cause of electrocardiogram artifact can avoid unnecessary pharmacological and non-pharmacological intervention to prevent arrhythmias.

  7. SOCIOLOGICAL MEDIA: MAXIMIZING STUDENT INTEREST IN QUANTITATIVE METHODS VIA COLLABORATIVE USE OF DIGITAL MEDIA

    Directory of Open Access Journals (Sweden)

    Frederick T. Tucker

    2016-10-01

    Full Text Available College sociology lecturers are tasked with inspiring student interest in quantitative methods despite widespread student anxiety about the subject, and a tendency for students to relieve classroom anxiety through habitual web browsing. In this paper, the author details the results of a pedagogical program whereby students at a New York City community college used industry-standard software to design, conduct, and analyze sociological surveys of one another, with the aim of inspiring student interest in quantitative methods and enhancing technical literacy. A chi-square test of independence was performed to determine the effect of the pedagogical process on the students’ ability to discuss sociological methods unrelated to their surveys in their final papers, compared with the author’s students from the previous semester who did not undergo the pedagogical program. The relation between these variables was significant, χ 2(3, N=36 = 9.8, p = .02. Findings suggest that community college students, under lecturer supervision, with minimal prior statistical knowledge, and access to digital media can collaborate in small groups to create and conduct sociological surveys, and discuss methods and results in limited classroom time. College sociology lecturers, instead of combatting student desire to use digital media, should harness this desire to advance student mastery of quantitative methods.

  8. Effects of Pre and Post-Rigor Marinade Injection on Some Quality Parameters of Longissimus Dorsi Muscles

    Science.gov (United States)

    Fadıloğlu, Eylem Ezgi; Serdaroğlu, Meltem

    2018-01-01

    Abstract This study was conducted to evaluate the effects of pre and post-rigor marinade injections on some quality parameters of Longissimus dorsi (LD) muscles. Three marinade formulations were prepared with 2% NaCl, 2% NaCl+0.5 M lactic acid and 2% NaCl+0.5 M sodium lactate. In this study marinade uptake, pH, free water, cooking loss, drip loss and color properties were analyzed. Injection time had significant effect on marinade uptake levels of samples. Regardless of marinate formulation, marinade uptake of pre-rigor samples injected with marinade solutions were higher than post rigor samples. Injection of sodium lactate increased pH values of samples whereas lactic acid injection decreased pH. Marinade treatment and storage period had significant effect on cooking loss. At each evaluation period interaction between marinade treatment and injection time showed different effect on free water content. Storage period and marinade application had significant effect on drip loss values. Drip loss in all samples increased during the storage. During all storage days, lowest CIE L* value was found in pre-rigor samples injected with sodium lactate. Lactic acid injection caused color fade in pre-rigor and post-rigor samples. Interaction between marinade treatment and storage period was found statistically significant (p<0.05). At day 0 and 3, the lowest CIE b* values obtained pre-rigor samples injected with sodium lactate and there were no differences were found in other samples. At day 6, no significant differences were found in CIE b* values of all samples. PMID:29805282

  9. Use of the Rigor Mortis Process as a Tool for Better Understanding of Skeletal Muscle Physiology: Effect of the Ante-Mortem Stress on the Progression of Rigor Mortis in Brook Charr (Salvelinus fontinalis).

    Science.gov (United States)

    Diouf, Boucar; Rioux, Pierre

    1999-01-01

    Presents the rigor mortis process in brook charr (Salvelinus fontinalis) as a tool for better understanding skeletal muscle metabolism. Describes an activity that demonstrates how rigor mortis is related to the post-mortem decrease of muscular glycogen and ATP, how glycogen degradation produces lactic acid that lowers muscle pH, and how…

  10. Measurements of the degree of development of rigor mortis as an indicator of stress in slaughtered pigs.

    Science.gov (United States)

    Warriss, P D; Brown, S N; Knowles, T G

    2003-12-13

    The degree of development of rigor mortis in the carcases of slaughter pigs was assessed subjectively on a three-point scale 35 minutes after they were exsanguinated, and related to the levels of cortisol, lactate and creatine kinase in blood collected at exsanguination. Earlier rigor development was associated with higher concentrations of these stress indicators in the blood. This relationship suggests that the mean rigor score, and the frequency distribution of carcases that had or had not entered rigor, could be used as an index of the degree of stress to which the pigs had been subjected.

  11. A gas chromatography-mass spectrometry method for the quantitation of clobenzorex.

    Science.gov (United States)

    Cody, J T; Valtier, S

    1999-01-01

    Drugs metabolized to amphetamine or methamphetamine are potentially significant concerns in the interpretation of amphetamine-positive urine drug-testing results. One of these compounds, clobenzorex, is an anorectic drug that is available in many countries. Clobenzorex (2-chlorobenzylamphetamine) is metabolized to amphetamine by the body and excreted in the urine. Following administration, the parent compound was detectable for a shorter time than the metabolite amphetamine, which could be detected for days. Because of the potential complication posed to the interpretation of amphetamin-positive drug tests following administration of this drug, the viability of a current amphetamine procedure using liquid-liquid extraction and conversion to the heptafluorobutyryl derivative followed by gas chromatography-mass spectrometry (GC-MS) analysis was evaluated for identification and quantitation of clobenzorex. Qualitative identification of the drug was relatively straightforward. Quantitative analysis proved to be a far more challenging process. Several compounds were evaluated for use as the internal standard in this method, including methamphetamine-d11, fenfluramine, benzphetamine, and diphenylamine. Results using these compounds proved to be less than satisfactory because of poor reproducibility of the quantitative values. Because of its similar chromatographic properties to the parent drug, the compound 3-chlorobenzylamphetamine (3-Cl-clobenzorex) was evaluated in this study as the internal standard for the quantitation of clobenzorex. Precision studies showed 3-Cl-clobenzorex to produce accurate and reliable quantitative results (within-run relative standard deviations [RSDs] clobenzorex.

  12. Quantitative analysis method for niobium in lead zirconate titanate

    International Nuclear Information System (INIS)

    Hara, Hideo; Hashimoto, Toshio

    1986-01-01

    Lead zirconate titanate (PZT) is a strong dielectric ceramic having piezoelectric and pyroelectric properties, and is used most as a piezoelectric material. Also it is a main component of lead lanthanum zirconate titanate (PLZT), which is a typical electrical-optical conversion element. Since these have been developed, the various electronic parts utilizing the piezoelectric characteristics have been put in practical use. The characteristics can be set up by changing the composition of PZT and the kinds and amount of additives. Among the additives, niobium has the action to make metallic ion vacancy in crystals, and by the formation of this vacancy, to ease the movement of domain walls in crystal grains, and to increase resistivity. Accordingly, it is necessary to accurately determine the niobium content for the research and development, quality control and process control. The quantitative analysis methods for niobium used so far have respective demerits, therefore, the authors examined the quantitative analysis of niobium in PZT by using an inductively coupled plasma emission spectro-analysis apparatus which has remarkably developed recently. As the result, the method of dissolving a specimen with hydrochloric acid and hydrofluoric acid, and masking unstable lead with ethylene diamine tetraacetic acid 2 sodium and fluoride ions with boric acid was established. The apparatus, reagents, the experiment and the results are reported. (Kako, I.)

  13. Quantitative magnetic resonance imaging and studies of degenerative diseases of the developing human brain

    International Nuclear Information System (INIS)

    Caviness, V.S. Jr.; Phil, D.; Filipek, P.A.; Kennedy, D.N.

    1992-01-01

    The Rett syndrome is a progressive disorder which is associated with regression of psychomotor development and precipitous deceleration of brain growth during the first year of life. General histopathological surveys in postmortem specimens have identified degeneration of subpopulations of neurons of the nigrostriatal system but no other evidence of degenerative process. Magnetic resonance imaging-based morphometry may usefully guide application of rigorous but demanding quantitative histologic search for evidence of neuronal degeneration. The volumes of the principal set of cortical and nuclear structures of principal interest in the disorder may be measured by currently avaiable MRI-based methods. Opimized levels of precision now allow detection of volumetric changes over time in the same brain of approximately 10% at the 95% confidence level. (author)

  14. A direct method for estimating the alpha/beta ratio from quantitative dose-response data

    International Nuclear Information System (INIS)

    Stuschke, M.

    1989-01-01

    A one-step optimization method based on a least squares fit of the linear quadratic model to quantitative tissue response data after fractionated irradiation is proposed. Suitable end-points that can be analysed by this method are growth delay, host survival and quantitative biochemical or clinical laboratory data. The functional dependence between the transformed dose and the measured response is approximated by a polynomial. The method allows for the estimation of the alpha/beta ratio and its confidence limits from all observed responses of the different fractionation schedules. Censored data can be included in the analysis. A method to test the appropriateness of the fit is presented. A computer simulation illustrates the method and its accuracy as examplified by the growth delay end point. A comparison with a fit of the linear quadratic model to interpolated isoeffect doses shows the advantages of the direct method. (orig./HP) [de

  15. Einstein's Theory A Rigorous Introduction for the Mathematically Untrained

    CERN Document Server

    Grøn, Øyvind

    2011-01-01

    This book provides an introduction to the theory of relativity and the mathematics used in its processes. Three elements of the book make it stand apart from previously published books on the theory of relativity. First, the book starts at a lower mathematical level than standard books with tensor calculus of sufficient maturity to make it possible to give detailed calculations of relativistic predictions of practical experiments. Self-contained introductions are given, for example vector calculus, differential calculus and integrations. Second, in-between calculations have been included, making it possible for the non-technical reader to follow step-by-step calculations. Thirdly, the conceptual development is gradual and rigorous in order to provide the inexperienced reader with a philosophically satisfying understanding of the theory.  Einstein's Theory: A Rigorous Introduction for the Mathematically Untrained aims to provide the reader with a sound conceptual understanding of both the special and genera...

  16. Statistically rigorous calculations do not support common input and long-term synchronization of motor-unit firings

    Science.gov (United States)

    Kline, Joshua C.

    2014-01-01

    Over the past four decades, various methods have been implemented to measure synchronization of motor-unit firings. In this work, we provide evidence that prior reports of the existence of universal common inputs to all motoneurons and the presence of long-term synchronization are misleading, because they did not use sufficiently rigorous statistical tests to detect synchronization. We developed a statistically based method (SigMax) for computing synchronization and tested it with data from 17,736 motor-unit pairs containing 1,035,225 firing instances from the first dorsal interosseous and vastus lateralis muscles—a data set one order of magnitude greater than that reported in previous studies. Only firing data, obtained from surface electromyographic signal decomposition with >95% accuracy, were used in the study. The data were not subjectively selected in any manner. Because of the size of our data set and the statistical rigor inherent to SigMax, we have confidence that the synchronization values that we calculated provide an improved estimate of physiologically driven synchronization. Compared with three other commonly used techniques, ours revealed three types of discrepancies that result from failing to use sufficient statistical tests necessary to detect synchronization. 1) On average, the z-score method falsely detected synchronization at 16 separate latencies in each motor-unit pair. 2) The cumulative sum method missed one out of every four synchronization identifications found by SigMax. 3) The common input assumption method identified synchronization from 100% of motor-unit pairs studied. SigMax revealed that only 50% of motor-unit pairs actually manifested synchronization. PMID:25210152

  17. Correlation of X-Ray Computed Tomography with Quantitative Nuclear Magnetic Resonance Methods for Pre-Clinical Measurement of Adipose and Lean Tissues in Living Mice

    Directory of Open Access Journals (Sweden)

    Matthew N. Metzinger

    2014-10-01

    Full Text Available Numerous obesity studies have coupled murine models with non-invasive methods to quantify body composition in longitudinal experiments, including X-ray computed tomography (CT or quantitative nuclear magnetic resonance (QMR. Both microCT and QMR have been separately validated with invasive techniques of adipose tissue quantification, like post-mortem fat extraction and measurement. Here we report a head-to-head study of both protocols using oil phantoms and mouse populations to determine the parameters that best align CT data with that from QMR. First, an in vitro analysis of oil/water mixtures was used to calibrate and assess the overall accuracy of microCT vs. QMR data. Next, experiments were conducted with two cohorts of living mice (either homogenous or heterogeneous by sex, age and genetic backgrounds to assess the microCT imaging technique for adipose tissue segmentation and quantification relative to QMR. Adipose mass values were obtained from microCT data with three different resolutions, after which the data were analyzed with different filter and segmentation settings. Strong linearity was noted between the adipose mass values obtained with microCT and QMR, with optimal parameters and scan conditions reported herein. Lean tissue (muscle, internal organs was also segmented and quantified using the microCT method relative to the analogous QMR values. Overall, the rigorous calibration and validation of the microCT method for murine body composition, relative to QMR, ensures its validity for segmentation, quantification and visualization of both adipose and lean tissues.

  18. A quantitative method to determine the orientation of collagen fibers in the dermis

    NARCIS (Netherlands)

    Noorlander, Maril L.; Melis, Paris; Jonker, Ard; van Noorden, Cornelis J. F.

    2002-01-01

    We have developed a quantitative microscopic method to determine changes in the orientation of collagen fibers in the dermis resulting from mechanical stress. The method is based on the use of picrosirius red-stained cryostat sections of piglet skin in which collagen fibers reflect light strongly

  19. Quantitative analysis of γ-oryzanol content in cold pressed rice bran oil by TLC-image analysis method

    OpenAIRE

    Sakunpak, Apirak; Suksaeree, Jirapornchai; Monton, Chaowalit; Pathompak, Pathamaporn; Kraisintu, Krisana

    2014-01-01

    Objective: To develop and validate an image analysis method for quantitative analysis of γ-oryzanol in cold pressed rice bran oil. Methods: TLC-densitometric and TLC-image analysis methods were developed, validated, and used for quantitative analysis of γ-oryzanol in cold pressed rice bran oil. The results obtained by these two different quantification methods were compared by paired t-test. Results: Both assays provided good linearity, accuracy, reproducibility and selectivity for dete...

  20. Rigorous Numerics for ill-posed PDEs: Periodic Orbits in the Boussinesq Equation

    Science.gov (United States)

    Castelli, Roberto; Gameiro, Marcio; Lessard, Jean-Philippe

    2018-04-01

    In this paper, we develop computer-assisted techniques for the analysis of periodic orbits of ill-posed partial differential equations. As a case study, our proposed method is applied to the Boussinesq equation, which has been investigated extensively because of its role in the theory of shallow water waves. The idea is to use the symmetry of the solutions and a Newton-Kantorovich type argument (the radii polynomial approach) to obtain rigorous proofs of existence of the periodic orbits in a weighted ℓ1 Banach space of space-time Fourier coefficients with exponential decay. We present several computer-assisted proofs of the existence of periodic orbits at different parameter values.

  1. A rigorous proof for the Landauer-Büttiker formula

    DEFF Research Database (Denmark)

    Cornean, Horia Decebal; Jensen, Arne; Moldoveanu, V.

    Recently, Avron et al. shed new light on the question of quantum transport in mesoscopic samples coupled to particle reservoirs by semi-infinite leads. They rigorously treat the case when the sample undergoes an adiabatic evolution thus generating a current through th leads, and prove the so call...

  2. Method of quantitative analysis of superconducting metal-conducting composite materials

    International Nuclear Information System (INIS)

    Bogomolov, V.N.; Zhuravlev, V.V.; Petranovskij, V.P.; Pimenov, V.A.

    1990-01-01

    Technique for quantitative analysis of superconducting metal-containing composite materials, SnO 2 -InSn, WO 3 -InW, Zn)-InZn in particular, has been developed. The method of determining metal content in a composite is based on the dependence of superconducting transition temperature on alloy composition. Sensitivity of temperature determination - 0.02K, error of analysis for InSn system - 0.5%

  3. Some selected quantitative methods of thermal image analysis in Matlab.

    Science.gov (United States)

    Koprowski, Robert

    2016-05-01

    The paper presents a new algorithm based on some selected automatic quantitative methods for analysing thermal images. It shows the practical implementation of these image analysis methods in Matlab. It enables to perform fully automated and reproducible measurements of selected parameters in thermal images. The paper also shows two examples of the use of the proposed image analysis methods for the area of ​​the skin of a human foot and face. The full source code of the developed application is also provided as an attachment. The main window of the program during dynamic analysis of the foot thermal image. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Project-Based Learning in Undergraduate Environmental Chemistry Laboratory: Using EPA Methods to Guide Student Method Development for Pesticide Quantitation

    Science.gov (United States)

    Davis, Eric J.; Pauls, Steve; Dick, Jonathan

    2017-01-01

    Presented is a project-based learning (PBL) laboratory approach for an upper-division environmental chemistry or quantitative analysis course. In this work, a combined laboratory class of 11 environmental chemistry students developed a method based on published EPA methods for the extraction of dichlorodiphenyltrichloroethane (DDT) and its…

  5. Method and platform standardization in MRM-based quantitative plasma proteomics.

    Science.gov (United States)

    Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Jackson, Angela M; Domanski, Dominik; Burkhart, Julia; Sickmann, Albert; Borchers, Christoph H

    2013-12-16

    There exists a growing demand in the proteomics community to standardize experimental methods and liquid chromatography-mass spectrometry (LC/MS) platforms in order to enable the acquisition of more precise and accurate quantitative data. This necessity is heightened by the evolving trend of verifying and validating candidate disease biomarkers in complex biofluids, such as blood plasma, through targeted multiple reaction monitoring (MRM)-based approaches with stable isotope-labeled standards (SIS). Considering the lack of performance standards for quantitative plasma proteomics, we previously developed two reference kits to evaluate the MRM with SIS peptide approach using undepleted and non-enriched human plasma. The first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). Here, these kits have been refined for practical use and then evaluated through intra- and inter-laboratory testing on 6 common LC/MS platforms. For an identical panel of 22 plasma proteins, similar concentrations were determined, regardless of the kit, instrument platform, and laboratory of analysis. These results demonstrate the value of the kit and reinforce the utility of standardized methods and protocols. The proteomics community needs standardized experimental protocols and quality control methods in order to improve the reproducibility of MS-based quantitative data. This need is heightened by the evolving trend for MRM-based validation of proposed disease biomarkers in complex biofluids such as blood plasma. We have developed two kits to assist in the inter- and intra-laboratory quality control of MRM experiments: the first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). In this paper, we report the use of these kits in intra- and inter-laboratory testing on 6 common LC/MS platforms. This

  6. Comparison of culture-based, vital stain and PMA-qPCR methods for the quantitative detection of viable hookworm ova.

    Science.gov (United States)

    Gyawali, P; Sidhu, J P S; Ahmed, W; Jagals, P; Toze, S

    2017-06-01

    Accurate quantitative measurement of viable hookworm ova from environmental samples is the key to controlling hookworm re-infections in the endemic regions. In this study, the accuracy of three quantitative detection methods [culture-based, vital stain and propidium monoazide-quantitative polymerase chain reaction (PMA-qPCR)] was evaluated by enumerating 1,000 ± 50 Ancylostoma caninum ova in the laboratory. The culture-based method was able to quantify an average of 397 ± 59 viable hookworm ova. Similarly, vital stain and PMA-qPCR methods quantified 644 ± 87 and 587 ± 91 viable ova, respectively. The numbers of viable ova estimated by the culture-based method were significantly (P methods. Therefore, both PMA-qPCR and vital stain methods appear to be suitable for the quantitative detection of viable hookworm ova. However, PMA-qPCR would be preferable over the vital stain method in scenarios where ova speciation is needed.

  7. Ambiguity, logic, simplicity, and dynamics: Wittgensteinian evaluative criteria in peer review of quantitative research on categorization.

    Science.gov (United States)

    Shimp, Charles P

    2004-06-30

    Research on categorization has changed over time, and some of these changes resemble how Wittgenstein's views changed from his Tractatus Logico-Philosophicus to his Philosophical Investigations. Wittgenstein initially focused on unambiguous, abstract, parsimonious, logical propositions and rules, and on independent, static, "atomic facts." This approach subsequently influenced the development of logical positivism and thereby may have indirectly influenced method and theory in research on categorization: much animal research on categorization has focused on learning simple, static, logical rules unambiguously interrelating small numbers of independent features. He later rejected logical simplicity and rigor and focused instead on Gestalt ideas about figure-ground reversals and context, the ambiguity of family resemblance, and the function of details of everyday language. Contemporary contextualism has been influenced by this latter position, some features of which appear in contemporary empirical research on categorization. These developmental changes are illustrated by research on avian local and global levels of visual perceptual analysis, categorization of rectangles and moving objects, and artificial grammar learning. Implications are described for peer review of quantitative theory in which ambiguity, logical rigor, simplicity, or dynamics are designed to play important roles.

  8. Development of a rapid method for the quantitative determination of deoxynivalenol using Quenchbody

    Energy Technology Data Exchange (ETDEWEB)

    Yoshinari, Tomoya [Division of Microbiology, National Institute of Health Sciences, 1-18-1, Kamiyoga, Setagaya-ku, Tokyo 158-8501 (Japan); Ohashi, Hiroyuki; Abe, Ryoji; Kaigome, Rena [Biomedical Division, Ushio Inc., 1-12 Minamiwatarida-cho, Kawasaki-ku, Kawasaki 210-0855 (Japan); Ohkawa, Hideo [Research Center for Environmental Genomics, Kobe University, 1-1 Rokkodai, Nada, Kobe 657-8501 (Japan); Sugita-Konishi, Yoshiko, E-mail: y-konishi@azabu-u.ac.jp [Department of Food and Life Science, Azabu University, 1-17-71 Fuchinobe, Chuo-ku, Sagamihara, Kanagawa 252-5201 (Japan)

    2015-08-12

    Quenchbody (Q-body) is a novel fluorescent biosensor based on the antigen-dependent removal of a quenching effect on a fluorophore attached to antibody domains. In order to develop a method using Q-body for the quantitative determination of deoxynivalenol (DON), a trichothecene mycotoxin produced by some Fusarium species, anti-DON Q-body was synthesized from the sequence information of a monoclonal antibody specific to DON. When the purified anti-DON Q-body was mixed with DON, a dose-dependent increase in the fluorescence intensity was observed and the detection range was between 0.0003 and 3 mg L{sup −1}. The coefficients of variation were 7.9% at 0.003 mg L{sup −1}, 5.0% at 0.03 mg L{sup −1} and 13.7% at 0.3 mg L{sup −1}, respectively. The limit of detection was 0.006 mg L{sup −1} for DON in wheat. The Q-body showed an antigen-dependent fluorescence enhancement even in the presence of wheat extracts. To validate the analytical method using Q-body, a spike-and-recovery experiment was performed using four spiked wheat samples. The recoveries were in the range of 94.9–100.2%. The concentrations of DON in twenty-one naturally contaminated wheat samples were quantitated by the Q-body method, LC-MS/MS and an immunochromatographic assay kit. The LC-MS/MS analysis showed that the levels of DON contamination in the samples were between 0.001 and 2.68 mg kg{sup −1}. The concentrations of DON quantitated by LC-MS/MS were more strongly correlated with those using the Q-body method (R{sup 2} = 0.9760) than the immunochromatographic assay kit (R{sup 2} = 0.8824). These data indicate that the Q-body system for the determination of DON in wheat samples was successfully developed and Q-body is expected to have a range of applications in the field of food safety. - Highlights: • A rapid method for quantitation of DON using Q-body has been developed. • A recovery test using the anti-DON Q-body was performed. • The concentrations of DON in wheat

  9. Advantages of a Dynamic RGGG Method in Qualitative and Quantitative Analysis

    International Nuclear Information System (INIS)

    Shin, Seung Ki; Seong, Poong Hyun

    2009-01-01

    Various researches have been conducted in order to analyze dynamic interactions among components and process variables in nuclear power plants which cannot be handled by static reliability analysis methods such as conventional fault tree and event tree techniques. A dynamic reliability graph with general gates (RGGG) method was proposed for an intuitive modeling of dynamic systems and it enables one to easily analyze huge and complex systems. In this paper, advantages of the dynamic RGGG method are assessed through two stages: system modeling and quantitative analysis. And then a software tool for dynamic RGGG method is introduced and an application to a real dynamic system is accompanied

  10. A method for three-dimensional quantitative observation of the microstructure of biological samples

    Science.gov (United States)

    Wang, Pengfei; Chen, Dieyan; Ma, Wanyun; Wu, Hongxin; Ji, Liang; Sun, Jialin; Lv, Danyu; Zhang, Lu; Li, Ying; Tian, Ning; Zheng, Jinggao; Zhao, Fengying

    2009-07-01

    Contemporary biology has developed into the era of cell biology and molecular biology, and people try to study the mechanism of all kinds of biological phenomena at the microcosmic level now. Accurate description of the microstructure of biological samples is exigent need from many biomedical experiments. This paper introduces a method for 3-dimensional quantitative observation on the microstructure of vital biological samples based on two photon laser scanning microscopy (TPLSM). TPLSM is a novel kind of fluorescence microscopy, which has excellence in its low optical damage, high resolution, deep penetration depth and suitability for 3-dimensional (3D) imaging. Fluorescent stained samples were observed by TPLSM, and afterward the original shapes of them were obtained through 3D image reconstruction. The spatial distribution of all objects in samples as well as their volumes could be derived by image segmentation and mathematic calculation. Thus the 3-dimensionally and quantitatively depicted microstructure of the samples was finally derived. We applied this method to quantitative analysis of the spatial distribution of chromosomes in meiotic mouse oocytes at metaphase, and wonderful results came out last.

  11. Characterization of rigor mortis of longissimus dorsi and triceps ...

    African Journals Online (AJOL)

    24 h) of the longissimus dorsi (LD) and triceps brachii (TB) muscles as well as the shear force (meat tenderness) and colour were evaluated, aiming at characterizing the rigor mortis in the meat during industrial processing. Data statistic treatment demonstrated that carcass temperature and pH decreased gradually during ...

  12. Characterization of working iron Fischer-Tropsch catalysts using quantitative diffraction methods

    Science.gov (United States)

    Mansker, Linda Denise

    This study presents the results of the ex-situ characterization of working iron Fischer-Tropsch synthesis (F-TS) catalysts, reacted hundreds of hours at elevated pressures, using a new quantitative x-ray diffraction analytical methodology. Compositions, iron phase structures, and phase particle morphologies were determined and correlated with the observed reaction kinetics. Conclusions were drawn about the character of each catalyst in its most and least active state. The identity of the active phase(s) in the Fe F-TS catalyst has been vigorously debated for more than 45 years. The highly-reduced catalyst, used to convert coal-derived syngas to hydrocarbon products, is thought to form a mixture of oxides, metal, and carbides upon pretreatment and reaction. Commonly, Soxhlet extraction is used to effect catalyst-product slurry separation; however, the extraction process could be producing irreversible changes in the catalyst, contributing to the conflicting results in the literature. X-ray diffraction doesn't require analyte-matrix separation before analysis, and can detect trace phases down to 300 ppm/2 nm; thus, working catalyst slurries could be characterized as-sampled. Data were quantitatively interpreted employing first principles methods, including the Rietveld polycrystalline structure method. Pretreated catalysts and pure phases were examined experimentally and modeled to explore specific behavior under x-rays. Then, the working catalyst slurries were quantitatively characterized. Empirical quantitation factors were calculated from experimental data or single crystal parameters, then validated using the Rietveld method results. In the most active form, after pretreatment in H 2 or in CO at Pambient, well-preserved working catalysts contained significant amounts of Fe7C3 with trace alpha-Fe, once reaction had commenced at elevated pressure. Amounts of Fe3O 4 were constant and small, with carbide dpavg 65 wt%, regardless of pretreatment gas and pressure, with

  13. Link-based quantitative methods to identify differentially coexpressed genes and gene Pairs

    Directory of Open Access Journals (Sweden)

    Ye Zhi-Qiang

    2011-08-01

    Full Text Available Abstract Background Differential coexpression analysis (DCEA is increasingly used for investigating the global transcriptional mechanisms underlying phenotypic changes. Current DCEA methods mostly adopt a gene connectivity-based strategy to estimate differential coexpression, which is characterized by comparing the numbers of gene neighbors in different coexpression networks. Although it simplifies the calculation, this strategy mixes up the identities of different coexpression neighbors of a gene, and fails to differentiate significant differential coexpression changes from those trivial ones. Especially, the correlation-reversal is easily missed although it probably indicates remarkable biological significance. Results We developed two link-based quantitative methods, DCp and DCe, to identify differentially coexpressed genes and gene pairs (links. Bearing the uniqueness of exploiting the quantitative coexpression change of each gene pair in the coexpression networks, both methods proved to be superior to currently popular methods in simulation studies. Re-mining of a publicly available type 2 diabetes (T2D expression dataset from the perspective of differential coexpression analysis led to additional discoveries than those from differential expression analysis. Conclusions This work pointed out the critical weakness of current popular DCEA methods, and proposed two link-based DCEA algorithms that will make contribution to the development of DCEA and help extend it to a broader spectrum.

  14. The value of quantitative methods for assessment of renal transplant and comparison with physician expertness

    International Nuclear Information System (INIS)

    Firouzi, F.; Fazeli, M.

    2002-01-01

    Radionuclide renal diagnostic studies play an important role in assessing renal allograft. Various quantitative parameters have been derived from the Radionuclide renogram to facilitate and confirm the changes in perfusion and/or function of kidney allograft. These quantitative methods were divided into parameters used for assessing renal graft perfusion and parameters used for evaluating parenchymal function. The blood flow in renal transplants can be quantified by measuring the rate of activity appearance in the kidney graft and the ratio of the integral activity under the transplanted kidney and arterial curves e.g. Hilton's perfusion index and Karachi's kidney/aortic ratio. Quantitative evaluation of graft extraction and excretion was assessed by parameters derived from 123 I/ 131 I-OH, 99 mTc-DTPA or 99 mTc-Mag renogram. In this study we review retrospectively renal transplanted patients scintigraphies that all of them under gone to renal allograft needle biopsy nearly to date of allograft scan. We performed quantitative methods for all patients. We observed perfusion parameters affected by quality of bolus injection and numerical aviations related to changes in the site and size of region of interest. Quantitative methods for renal parenchymal functions were nonspecific and far from defining a specific cause of graft dysfunction. In conclusion, neither perfusion nor parenchymal parameters have not enough diagnostic power for specific diagnosis of graft dysfunction. Physician expertness by using scintigraphic images and renogram curves is more sensitive and specific for diagnosis of renal allograft dysfunction

  15. Rigorous Quantum Field Theory A Festschrift for Jacques Bros

    CERN Document Server

    Monvel, Anne Boutet; Iagolnitzer, Daniel; Moschella, Ugo

    2007-01-01

    Jacques Bros has greatly advanced our present understanding of rigorous quantum field theory through numerous fundamental contributions. This book arose from an international symposium held in honour of Jacques Bros on the occasion of his 70th birthday, at the Department of Theoretical Physics of the CEA in Saclay, France. The impact of the work of Jacques Bros is evident in several articles in this book. Quantum fields are regarded as genuine mathematical objects, whose various properties and relevant physical interpretations must be studied in a well-defined mathematical framework. The key topics in this volume include analytic structures of Quantum Field Theory (QFT), renormalization group methods, gauge QFT, stability properties and extension of the axiomatic framework, QFT on models of curved spacetimes, QFT on noncommutative Minkowski spacetime. Contributors: D. Bahns, M. Bertola, R. Brunetti, D. Buchholz, A. Connes, F. Corbetta, S. Doplicher, M. Dubois-Violette, M. Dütsch, H. Epstein, C.J. Fewster, K....

  16. Software metrics a rigorous and practical approach

    CERN Document Server

    Fenton, Norman

    2014-01-01

    A Framework for Managing, Measuring, and Predicting Attributes of Software Development Products and ProcessesReflecting the immense progress in the development and use of software metrics in the past decades, Software Metrics: A Rigorous and Practical Approach, Third Edition provides an up-to-date, accessible, and comprehensive introduction to software metrics. Like its popular predecessors, this third edition discusses important issues, explains essential concepts, and offers new approaches for tackling long-standing problems.New to the Third EditionThis edition contains new material relevant

  17. Real time quantitative phase microscopy based on single-shot transport of intensity equation (ssTIE) method

    Science.gov (United States)

    Yu, Wei; Tian, Xiaolin; He, Xiaoliang; Song, Xiaojun; Xue, Liang; Liu, Cheng; Wang, Shouyu

    2016-08-01

    Microscopy based on transport of intensity equation provides quantitative phase distributions which opens another perspective for cellular observations. However, it requires multi-focal image capturing while mechanical and electrical scanning limits its real time capacity in sample detections. Here, in order to break through this restriction, real time quantitative phase microscopy based on single-shot transport of the intensity equation method is proposed. A programmed phase mask is designed to realize simultaneous multi-focal image recording without any scanning; thus, phase distributions can be quantitatively retrieved in real time. It is believed the proposed method can be potentially applied in various biological and medical applications, especially for live cell imaging.

  18. Composition and Quantitation of Microalgal Lipids by ERETIC 1H NMR Method

    Directory of Open Access Journals (Sweden)

    Angelo Fontana

    2013-09-01

    Full Text Available Accurate characterization of biomass constituents is a crucial aspect of research in the biotechnological application of natural products. Here we report an efficient, fast and reproducible method for the identification and quantitation of fatty acids and complex lipids (triacylglycerols, glycolipids, phospholipids in microalgae under investigation for the development of functional health products (probiotics, food ingredients, drugs, etc. or third generation biofuels. The procedure consists of extraction of the biological matrix by modified Folch method and direct analysis of the resulting material by proton nuclear magnetic resonance (1H NMR. The protocol uses a reference electronic signal as external standard (ERETIC method and allows assessment of total lipid content, saturation degree and class distribution in both high throughput screening of algal collection and metabolic analysis during genetic or culturing studies. As proof of concept, the methodology was applied to the analysis of three microalgal species (Thalassiosira weissflogii, Cyclotella cryptica and Nannochloropsis salina which drastically differ for the qualitative and quantitative composition of their fatty acid-based lipids.

  19. Quantitative method of measuring cancer cell urokinase and metastatic potential

    Science.gov (United States)

    Morrison, Dennis R. (Inventor)

    1993-01-01

    The metastatic potential of tumors can be evaluated by the quantitative detection of urokinase and DNA. The cell sample selected for examination is analyzed for the presence of high levels of urokinase and abnormal DNA using analytical flow cytometry and digital image analysis. Other factors such as membrane associated urokinase, increased DNA synthesis rates and certain receptors can be used in the method for detection of potentially invasive tumors.

  20. Rigorous force field optimization principles based on statistical distance minimization

    Energy Technology Data Exchange (ETDEWEB)

    Vlcek, Lukas, E-mail: vlcekl1@ornl.gov [Chemical Sciences Division, Geochemistry & Interfacial Sciences Group, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6110 (United States); Joint Institute for Computational Sciences, University of Tennessee, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6173 (United States); Chialvo, Ariel A. [Chemical Sciences Division, Geochemistry & Interfacial Sciences Group, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6110 (United States)

    2015-10-14

    We use the concept of statistical distance to define a measure of distinguishability between a pair of statistical mechanical systems, i.e., a model and its target, and show that its minimization leads to general convergence of the model’s static measurable properties to those of the target. We exploit this feature to define a rigorous basis for the development of accurate and robust effective molecular force fields that are inherently compatible with coarse-grained experimental data. The new model optimization principles and their efficient implementation are illustrated through selected examples, whose outcome demonstrates the higher robustness and predictive accuracy of the approach compared to other currently used methods, such as force matching and relative entropy minimization. We also discuss relations between the newly developed principles and established thermodynamic concepts, which include the Gibbs-Bogoliubov inequality and the thermodynamic length.

  1. Reconciling the Rigor-Relevance Dilemma in Intellectual Capital Research

    Science.gov (United States)

    Andriessen, Daniel

    2004-01-01

    This paper raises the issue of research methodology for intellectual capital and other types of management research by focusing on the dilemma of rigour versus relevance. The more traditional explanatory approach to research often leads to rigorous results that are not of much help to solve practical problems. This paper describes an alternative…

  2. Quantitative Methods in the Study of Local History

    Science.gov (United States)

    Davey, Pene

    1974-01-01

    The author suggests how the quantitative analysis of data from census records, assessment roles, and newspapers may be integrated into the classroom. Suggestions for obtaining quantitative data are provided. (DE)

  3. Unbiased stereological methods used for the quantitative evaluation of guided bone regeneration

    DEFF Research Database (Denmark)

    Aaboe, Else Merete; Pinholt, E M; Schou, S

    1998-01-01

    The present study describes the use of unbiased stereological methods for the quantitative evaluation of the amount of regenerated bone. Using the principle of guided bone regeneration the amount of regenerated bone after placement of degradable or non-degradable membranes covering defects...

  4. The use of digital PCR to improve the application of quantitative molecular diagnostic methods for tuberculosis.

    Science.gov (United States)

    Devonshire, Alison S; O'Sullivan, Denise M; Honeyborne, Isobella; Jones, Gerwyn; Karczmarczyk, Maria; Pavšič, Jernej; Gutteridge, Alice; Milavec, Mojca; Mendoza, Pablo; Schimmel, Heinz; Van Heuverswyn, Fran; Gorton, Rebecca; Cirillo, Daniela Maria; Borroni, Emanuele; Harris, Kathryn; Barnard, Marinus; Heydenrych, Anthenette; Ndusilo, Norah; Wallis, Carole L; Pillay, Keshree; Barry, Thomas; Reddington, Kate; Richter, Elvira; Mozioğlu, Erkan; Akyürek, Sema; Yalçınkaya, Burhanettin; Akgoz, Muslum; Žel, Jana; Foy, Carole A; McHugh, Timothy D; Huggett, Jim F

    2016-08-03

    Real-time PCR (qPCR) based methods, such as the Xpert MTB/RIF, are increasingly being used to diagnose tuberculosis (TB). While qualitative methods are adequate for diagnosis, the therapeutic monitoring of TB patients requires quantitative methods currently performed using smear microscopy. The potential use of quantitative molecular measurements for therapeutic monitoring has been investigated but findings have been variable and inconclusive. The lack of an adequate reference method and reference materials is a barrier to understanding the source of such disagreement. Digital PCR (dPCR) offers the potential for an accurate method for quantification of specific DNA sequences in reference materials which can be used to evaluate quantitative molecular methods for TB treatment monitoring. To assess a novel approach for the development of quality assurance materials we used dPCR to quantify specific DNA sequences in a range of prototype reference materials and evaluated accuracy between different laboratories and instruments. The materials were then also used to evaluate the quantitative performance of qPCR and Xpert MTB/RIF in eight clinical testing laboratories. dPCR was found to provide results in good agreement with the other methods tested and to be highly reproducible between laboratories without calibration even when using different instruments. When the reference materials were analysed with qPCR and Xpert MTB/RIF by clinical laboratories, all laboratories were able to correctly rank the reference materials according to concentration, however there was a marked difference in the measured magnitude. TB is a disease where the quantification of the pathogen could lead to better patient management and qPCR methods offer the potential to rapidly perform such analysis. However, our findings suggest that when precisely characterised materials are used to evaluate qPCR methods, the measurement result variation is too high to determine whether molecular quantification

  5. Semi-quantitative methods yield greater inter- and intraobserver agreement than subjective methods for interpreting 99m technetium-hydroxymethylene-diphosphonate uptake in equine thoracic processi spinosi.

    Science.gov (United States)

    van Zadelhoff, Claudia; Ehrle, Anna; Merle, Roswitha; Jahn, Werner; Lischer, Christoph

    2018-05-09

    Scintigraphy is a standard diagnostic method for evaluating horses with back pain due to suspected thoracic processus spinosus pathology. Lesion detection is based on subjective or semi-quantitative assessments of increased uptake. This retrospective, analytical study is aimed to compare semi-quantitative and subjective methods in the evaluation of scintigraphic images of the processi spinosi in the equine thoracic spine. Scintigraphic images of 20 Warmblood horses, presented for assessment of orthopedic conditions between 2014 and 2016, were included in the study. Randomized, blinded image evaluation was performed by 11 veterinarians using subjective and semi-quantitative methods. Subjective grading was performed for the analysis of red-green-blue and grayscale scintigraphic images, which were presented in full-size or as masked images. For the semi-quantitative assessment, observers placed regions of interest over each processus spinosus. The uptake ratio of each processus spinosus in comparison to a reference region of interest was determined. Subsequently, a modified semi-quantitative calculation was developed whereby only the highest counts-per-pixel for a specified number of pixels was processed. Inter- and intraobserver agreement was calculated using intraclass correlation coefficients. Inter- and intraobserver intraclass correlation coefficients were 41.65% and 71.39%, respectively, for the subjective image assessment. Additionally, a correlation between intraobserver agreement, experience, and grayscale images was identified. The inter- and intraobserver agreement was significantly increased when using semi-quantitative analysis (97.35% and 98.36%, respectively) or the modified semi-quantitative calculation (98.61% and 98.82%, respectively). The proposed modified semi-quantitative technique showed a higher inter- and intraobserver agreement when compared to other methods, which makes it a useful tool for the analysis of scintigraphic images. The

  6. Rigorous upper bounds for transport due to passive advection by inhomogeneous turbulence

    International Nuclear Information System (INIS)

    Krommes, J.A.; Smith, R.A.

    1987-05-01

    A variational procedure, due originally to Howard and explored by Busse and others for self-consistent turbulence problems, is employed to determine rigorous upper bounds for the advection of a passive scalar through an inhomogeneous turbulent slab with arbitrary generalized Reynolds number R and Kubo number K. In the basic version of the method, the steady-state energy balance is used as a constraint; the resulting bound, though rigorous, is independent of K. A pedagogical reference model (one dimension, K = ∞) is described in detail; the bound compares favorably with the exact solution. The direct-interaction approximation is also worked out for this model; it is somewhat more accurate than the bound, but requires considerably more labor to solve. For the basic bound, a general formalism is presented for several dimensions, finite correlation length, and reasonably general boundary conditions. Part of the general method, in which a Green's function technique is employed, applies to self-consistent as well as to passive problems, and thereby generalizes previous results in the fluid literature. The formalism is extended for the first time to include time-dependent constraints, and a bound is deduced which explicitly depends on K and has the correct physical scalings in all regimes of R and K. Two applications from the theory of turbulent plasmas ae described: flux in velocity space, and test particle transport in stochastic magnetic fields. For the velocity space problem the simplest bound reproduces Dupree's original scaling for the strong turbulence diffusion coefficient. For the case of stochastic magnetic fields, the scaling of the bounds is described for the magnetic diffusion coefficient as well as for the particle diffusion coefficient in the so-called collisionless, fluid, and double-streaming regimes

  7. Objective evaluation of reconstruction methods for quantitative SPECT imaging in the absence of ground truth.

    Science.gov (United States)

    Jha, Abhinav K; Song, Na; Caffo, Brian; Frey, Eric C

    2015-04-13

    Quantitative single-photon emission computed tomography (SPECT) imaging is emerging as an important tool in clinical studies and biomedical research. There is thus a need for optimization and evaluation of systems and algorithms that are being developed for quantitative SPECT imaging. An appropriate objective method to evaluate these systems is by comparing their performance in the end task that is required in quantitative SPECT imaging, such as estimating the mean activity concentration in a volume of interest (VOI) in a patient image. This objective evaluation can be performed if the true value of the estimated parameter is known, i.e. we have a gold standard. However, very rarely is this gold standard known in human studies. Thus, no-gold-standard techniques to optimize and evaluate systems and algorithms in the absence of gold standard are required. In this work, we developed a no-gold-standard technique to objectively evaluate reconstruction methods used in quantitative SPECT when the parameter to be estimated is the mean activity concentration in a VOI. We studied the performance of the technique with realistic simulated image data generated from an object database consisting of five phantom anatomies with all possible combinations of five sets of organ uptakes, where each anatomy consisted of eight different organ VOIs. Results indicate that the method provided accurate ranking of the reconstruction methods. We also demonstrated the application of consistency checks to test the no-gold-standard output.

  8. A novel semi-quantitative method for measuring tissue bleeding.

    Science.gov (United States)

    Vukcevic, G; Volarevic, V; Raicevic, S; Tanaskovic, I; Milicic, B; Vulovic, T; Arsenijevic, S

    2014-03-01

    In this study, we describe a new semi-quantitative method for measuring the extent of bleeding in pathohistological tissue samples. To test our novel method, we recruited 120 female patients in their first trimester of pregnancy and divided them into three groups of 40. Group I was the control group, in which no dilation was applied. Group II was an experimental group, in which dilation was performed using classical mechanical dilators. Group III was also an experimental group, in which dilation was performed using a hydraulic dilator. Tissue samples were taken from the patients' cervical canals using a Novak's probe via energetic single-step curettage prior to any dilation in Group I and after dilation in Groups II and III. After the tissue samples were prepared, light microscopy was used to obtain microphotographs at 100x magnification. The surfaces affected by bleeding were measured in the microphotographs using the Autodesk AutoCAD 2009 program and its "polylines" function. The lines were used to mark the area around the entire sample (marked A) and to create "polyline" areas around each bleeding area on the sample (marked B). The percentage of the total area affected by bleeding was calculated using the formula: N = Bt x 100 / At where N is the percentage (%) of the tissue sample surface affected by bleeding, At (A total) is the sum of the surfaces of all of the tissue samples and Bt (B total) is the sum of all the surfaces affected by bleeding in all of the tissue samples. This novel semi-quantitative method utilizes the Autodesk AutoCAD 2009 program, which is simple to use and widely available, thereby offering a new, objective and precise approach to estimate the extent of bleeding in tissue samples.

  9. Are Teacher Course Evaluations Biased against Faculty That Teach Quantitative Methods Courses?

    Science.gov (United States)

    Royal, Kenneth D.; Stockdale, Myrah R.

    2015-01-01

    The present study investigated graduate students' responses to teacher/course evaluations (TCE) to determine if students' responses were inherently biased against faculty who teach quantitative methods courses. Item response theory (IRT) and Differential Item Functioning (DIF) techniques were utilized for data analysis. Results indicate students…

  10. Quality properties of pre- and post-rigor beef muscle after interventions with high frequency ultrasound.

    Science.gov (United States)

    Sikes, Anita L; Mawson, Raymond; Stark, Janet; Warner, Robyn

    2014-11-01

    The delivery of a consistent quality product to the consumer is vitally important for the food industry. The aim of this study was to investigate the potential for using high frequency ultrasound applied to pre- and post-rigor beef muscle on the metabolism and subsequent quality. High frequency ultrasound (600kHz at 48kPa and 65kPa acoustic pressure) applied to post-rigor beef striploin steaks resulted in no significant effect on the texture (peak force value) of cooked steaks as measured by a Tenderometer. There was no added benefit of ultrasound treatment above that of the normal ageing process after ageing of the steaks for 7days at 4°C. Ultrasound treatment of post-rigor beef steaks resulted in a darkening of fresh steaks but after ageing for 7days at 4°C, the ultrasound-treated steaks were similar in colour to that of the aged, untreated steaks. High frequency ultrasound (2MHz at 48kPa acoustic pressure) applied to pre-rigor beef neck muscle had no effect on the pH, but the calculated exhaustion factor suggested that there was some effect on metabolism and actin-myosin interaction. However, the resultant texture of cooked, ultrasound-treated muscle was lower in tenderness compared to the control sample. After ageing for 3weeks at 0°C, the ultrasound-treated samples had the same peak force value as the control. High frequency ultrasound had no significant effect on the colour parameters of pre-rigor beef neck muscle. This proof-of-concept study showed no effect of ultrasound on quality but did indicate that the application of high frequency ultrasound to pre-rigor beef muscle shows potential for modifying ATP turnover and further investigation is warranted. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.

  11. Clinically Relevant Subregions of Articular Cartilage of the Hip for Analysis and Reporting Quantitative Magnetic Resonance Imaging: A Technical Note.

    Science.gov (United States)

    Surowiec, Rachel K; Lucas, Erin P; Wilson, Katharine J; Saroki, Adriana J; Ho, Charles P

    2014-01-01

    Before quantitative imaging techniques can become clinically valuable, the method, and more specifically, the regions of locating and reporting these values should be standardized toward reproducibility comparisons across centers and longitudinal follow-up of individual patients. The purpose of this technical note is to describe a rigorous and reproducible method of locating, analyzing, and reporting quantitative MRI values in hip articular cartilage with an approach that is consistent with current orthopedic literature. To demonstrate this localization and documentation, 3 patients (age, 23 ± 5.1 years; 2 males, 1 female) who presented with symptomatic mixed-type femoroacetabular impingement (α angle, 63.3° ± 2.1°; center edge angle, 39° ± 4.2°) were evaluated with T2-mapping at 3 T MRI prior to hip arthroscopy. Manual segmentation was performed and cartilage of the acetabulum and femur was divided into 12 subregions adapted from the geographic zone method. Bone landmarks in the acetabulum and femur, identifiable both in arthroscopy and MR images, were manually selected and the coordinates exported for division of cartilage. Mean T2 values in each zone are presented. The current work outlines a standardized system to locate and describe quantitative mapping values that could aid in surgical decision making, planning, and the noninvasive longitudinal follow-up of implemented cartilage preservation and restoration techniques.

  12. Quantitative analysis of the anti-noise performance of an m-sequence in an electromagnetic method

    Science.gov (United States)

    Yuan, Zhe; Zhang, Yiming; Zheng, Qijia

    2018-02-01

    An electromagnetic method with a transmitted waveform coded by an m-sequence achieved better anti-noise performance compared to the conventional manner with a square-wave. The anti-noise performance of the m-sequence varied with multiple coding parameters; hence, a quantitative analysis of the anti-noise performance for m-sequences with different coding parameters was required to optimize them. This paper proposes the concept of an identification system, with the identified Earth impulse response obtained by measuring the system output with the input of the voltage response. A quantitative analysis of the anti-noise performance of the m-sequence was achieved by analyzing the amplitude-frequency response of the corresponding identification system. The effects of the coding parameters on the anti-noise performance are summarized by numerical simulation, and their optimization is further discussed in our conclusions; the validity of the conclusions is further verified by field experiment. The quantitative analysis method proposed in this paper provides a new insight into the anti-noise mechanism of the m-sequence, and could be used to evaluate the anti-noise performance of artificial sources in other time-domain exploration methods, such as the seismic method.

  13. A Method for Quantitative Determination of Biofilm Viability

    Directory of Open Access Journals (Sweden)

    Maria Strømme

    2012-06-01

    Full Text Available In this study we present a scheme for quantitative determination of biofilm viability offering significant improvement over existing methods with metabolic assays. Existing metabolic assays for quantifying viable bacteria in biofilms usually utilize calibration curves derived from planktonic bacteria, which can introduce large errors due to significant differences in the metabolic and/or growth rates of biofilm bacteria in the assay media compared to their planktonic counterparts. In the presented method we derive the specific growth rate of Streptococcus mutans bacteria biofilm from a series of metabolic assays using the pH indicator phenol red, and show that this information could be used to more accurately quantify the relative number of viable bacteria in a biofilm. We found that the specific growth rate of S. mutans in biofilm mode of growth was 0.70 h−1, compared to 1.09 h−1 in planktonic growth. This method should be applicable to other bacteria types, as well as other metabolic assays, and, for example, to quantify the effect of antibacterial treatments or the performance of bactericidal implant surfaces.

  14. Striation Patterns of Ox Muscle in Rigor Mortis

    Science.gov (United States)

    Locker, Ronald H.

    1959-01-01

    Ox muscle in rigor mortis offers a selection of myofibrils fixed at varying degrees of contraction from sarcomere lengths of 3.7 to 0.7 µ. A study of this material by phase contrast and electron microscopy has revealed four distinct successive patterns of contraction, including besides the familiar relaxed and contracture patterns, two intermediate types (2.4 to 1.9 µ, 1.8 to 1.5 µ) not previously well described. PMID:14417790

  15. A simplified method for quantitative assessment of the relative health and safety risk of environmental management activities

    International Nuclear Information System (INIS)

    Eide, S.A.; Smith, T.H.; Peatross, R.G.; Stepan, I.E.

    1996-09-01

    This report presents a simplified method to assess the health and safety risk of Environmental Management activities of the US Department of Energy (DOE). The method applies to all types of Environmental Management activities including waste management, environmental restoration, and decontamination and decommissioning. The method is particularly useful for planning or tradeoff studies involving multiple conceptual options because it combines rapid evaluation with a quantitative approach. The method is also potentially applicable to risk assessments of activities other than DOE Environmental Management activities if rapid quantitative results are desired

  16. Mathematical framework for fast and rigorous track fit for the ZEUS detector

    Energy Technology Data Exchange (ETDEWEB)

    Spiridonov, Alexander

    2008-12-15

    In this note we present a mathematical framework for a rigorous approach to a common track fit for trackers located in the inner region of the ZEUS detector. The approach makes use of the Kalman filter and offers a rigorous treatment of magnetic field inhomogeneity, multiple scattering and energy loss. We describe mathematical details of the implementation of the Kalman filter technique with a reduced amount of computations for a cylindrical drift chamber, barrel and forward silicon strip detectors and a forward straw drift chamber. Options with homogeneous and inhomogeneous field are discussed. The fitting of tracks in one ZEUS event takes about of 20ms on standard PC. (orig.)

  17. Effects of ROI definition and reconstruction method on quantitative outcome and applicability in a response monitoring trial

    International Nuclear Information System (INIS)

    Krak, Nanda C.; Boellaard, R.; Hoekstra, Otto S.; Hoekstra, Corneline J.; Twisk, Jos W.R.; Lammertsma, Adriaan A.

    2005-01-01

    Quantitative measurement of tracer uptake in a tumour can be influenced by a number of factors, including the method of defining regions of interest (ROIs) and the reconstruction parameters used. The main purpose of this study was to determine the effects of different ROI methods on quantitative outcome, using two reconstruction methods and the standard uptake value (SUV) as a simple quantitative measure of FDG uptake. Four commonly used methods of ROI definition (manual placement, fixed dimensions, threshold based and maximum pixel value) were used to calculate SUV (SUV [MAN] , SUV 15 mm , SUV 50 , SUV 75 and SUV max , respectively) and to generate ''metabolic'' tumour volumes. Test-retest reproducibility of SUVs and of ''metabolic'' tumour volumes and the applicability of ROI methods during chemotherapy were assessed. In addition, SUVs calculated on ordered subsets expectation maximisation (OSEM) and filtered back-projection (FBP) images were compared. ROI definition had a direct effect on quantitative outcome. On average, SUV [MAN] , SUV 15 mm , SUV 50 and SUV 75 , were respectively 48%, 27%, 34% and 15% lower than SUV max when calculated on OSEM images. No statistically significant differences were found between SUVs calculated on OSEM and FBP reconstructed images. Highest reproducibility was found for SUV 15 mm and SUV [MAN] (ICC 0.95 and 0.94, respectively) and for ''metabolic'' volumes measured with the manual and 50% threshold ROIs (ICC 0.99 for both). Manual, 75% threshold and maximum pixel ROIs could be used throughout therapy, regardless of changes in tumour uptake or geometry. SUVs showed the same trend in relative change in FDG uptake after chemotherapy, irrespective of the ROI method used. The method of ROI definition has a direct influence on quantitative outcome. In terms of simplicity, user-independence, reproducibility and general applicability the threshold-based and fixed dimension methods are the best ROI methods. Threshold methods are in

  18. Quantitative methods for evaluating the efficacy of thalamic deep brain stimulation in patients with essential tremor.

    Science.gov (United States)

    Wastensson, Gunilla; Holmberg, Björn; Johnels, Bo; Barregard, Lars

    2013-01-01

    Deep brain stimulation (DBS) of the thalamus is a safe and efficient method for treatment of disabling tremor in patient with essential tremor (ET). However, successful tremor suppression after surgery requires careful selection of stimulus parameters. Our aim was to examine the possible use of certain quantitative methods for evaluating the efficacy of thalamic DBS in ET patients in clinical practice, and to compare these methods with traditional clinical tests. We examined 22 patients using the Essential Tremor Rating Scale (ETRS) and quantitative assessment of tremor with the stimulator both activated and deactivated. We used an accelerometer (CATSYS tremor Pen) for quantitative measurement of postural tremor, and a eurythmokinesimeter (EKM) to evaluate kinetic tremor in a rapid pointing task. The efficacy of DBS on tremor suppression was prominent irrespective of the method used. The agreement between clinical rating of postural tremor and tremor intensity as measured by the CATSYS tremor pen was relatively high (rs = 0.74). The agreement between kinetic tremor as assessed by the ETRS and the main outcome variable from the EKM test was low (rs = 0.34). The lack of agreement indicates that the EKM test is not comparable with the clinical test. Quantitative methods, such as the CATSYS tremor pen, could be a useful complement to clinical tremor assessment in evaluating the efficacy of DBS in clinical practice. Future studies should evaluate the precision of these methods and long-term impact on tremor suppression, activities of daily living (ADL) function and quality of life.

  19. Quantitative mass spectrometric analysis of glycoproteins combined with enrichment methods.

    Science.gov (United States)

    Ahn, Yeong Hee; Kim, Jin Young; Yoo, Jong Shin

    2015-01-01

    Mass spectrometry (MS) has been a core technology for high sensitive and high-throughput analysis of the enriched glycoproteome in aspects of quantitative assays as well as qualitative profiling of glycoproteins. Because it has been widely recognized that aberrant glycosylation in a glycoprotein may involve in progression of a certain disease, the development of efficient analysis tool for the aberrant glycoproteins is very important for deep understanding about pathological function of the glycoprotein and new biomarker development. This review first describes the protein glycosylation-targeting enrichment technologies mainly employing solid-phase extraction methods such as hydrizide-capturing, lectin-specific capturing, and affinity separation techniques based on porous graphitized carbon, hydrophilic interaction chromatography, or immobilized boronic acid. Second, MS-based quantitative analysis strategies coupled with the protein glycosylation-targeting enrichment technologies, by using a label-free MS, stable isotope-labeling, or targeted multiple reaction monitoring (MRM) MS, are summarized with recent published studies. © 2014 The Authors. Mass Spectrometry Reviews Published by Wiley Periodicals, Inc.

  20. Method for the quantitation of steroids in umbilical cord plasma

    International Nuclear Information System (INIS)

    Schindler, A.E.; Sparke, H.

    1975-01-01

    A method for simultaneous quantitation of nine steroids in cord plasma is described which consisted of Amberlite XAD-2 column chromatography at constant temperature of 45 degC, enzyme hydrolysis with β-glucoronidase/aryl sulfatase, addition of five radioactive internal standards, ethyl acetate extraction, thin-layer chromatography and quantitation by gas-liquid chromatography after trimethylsilyl ether derivative formation. Reliability criteria were established and the following steroid concentrations found: progesterone, 132.1+-102.5 μg/100 ml; pregnenolone, 57.3+-45.7 μg/100 ml; dehydroepiandrosterone, 46.5+-29.4 μg/100 ml; pregnanediol, 67.5+-46.6 μg/100 ml; 16-ketoandrostenediol, 19.8+-13.7 μg/100 ml; 16 α-hydroxydehydroepiandrosterone, 126.3+-86.9 μg/100 ml; 16 α-hydroxypregnenolone, 78.2+-56.5 μg/100 ml; androstenetriol, 22.2+-17.5 μg/100 ml and oestriol, 127.7+-116.9 μg/100 ml. (author)

  1. Quantitative assessment of contact and non-contact lateral force calibration methods for atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tran Khac, Bien Cuong; Chung, Koo-Hyun, E-mail: khchung@ulsan.ac.kr

    2016-02-15

    Atomic Force Microscopy (AFM) has been widely used for measuring friction force at the nano-scale. However, one of the key challenges faced by AFM researchers is to calibrate an AFM system to interpret a lateral force signal as a quantifiable force. In this study, five rectangular cantilevers were used to quantitatively compare three different lateral force calibration methods to demonstrate the legitimacy and to establish confidence in the quantitative integrity of the proposed methods. The Flat-Wedge method is based on a variation of the lateral output on a surface with flat and changing slopes, the Multi-Load Pivot method is based on taking pivot measurements at several locations along the cantilever length, and the Lateral AFM Thermal-Sader method is based on determining the optical lever sensitivity from the thermal noise spectrum of the first torsional mode with a known torsional spring constant from the Sader method. The results of the calibration using the Flat-Wedge and Multi-Load Pivot methods were found to be consistent within experimental uncertainties, and the experimental uncertainties of the two methods were found to be less than 15%. However, the lateral force sensitivity determined by the Lateral AFM Thermal-Sader method was found to be 8–29% smaller than those obtained from the other two methods. This discrepancy decreased to 3–19% when the torsional mode correction factor for an ideal cantilever was used, which suggests that the torsional mode correction should be taken into account to establish confidence in Lateral AFM Thermal-Sader method. - Highlights: • Quantitative assessment of three lateral force calibration methods for AFM. • Advantages and disadvantages of three different lateral force calibration method. • Implementation of Multi-Load Pivot method as non-contact calibration technique. • The torsional mode correction for Lateral AFM Thermal-Sader method.

  2. Quantitative assessment of contact and non-contact lateral force calibration methods for atomic force microscopy

    International Nuclear Information System (INIS)

    Tran Khac, Bien Cuong; Chung, Koo-Hyun

    2016-01-01

    Atomic Force Microscopy (AFM) has been widely used for measuring friction force at the nano-scale. However, one of the key challenges faced by AFM researchers is to calibrate an AFM system to interpret a lateral force signal as a quantifiable force. In this study, five rectangular cantilevers were used to quantitatively compare three different lateral force calibration methods to demonstrate the legitimacy and to establish confidence in the quantitative integrity of the proposed methods. The Flat-Wedge method is based on a variation of the lateral output on a surface with flat and changing slopes, the Multi-Load Pivot method is based on taking pivot measurements at several locations along the cantilever length, and the Lateral AFM Thermal-Sader method is based on determining the optical lever sensitivity from the thermal noise spectrum of the first torsional mode with a known torsional spring constant from the Sader method. The results of the calibration using the Flat-Wedge and Multi-Load Pivot methods were found to be consistent within experimental uncertainties, and the experimental uncertainties of the two methods were found to be less than 15%. However, the lateral force sensitivity determined by the Lateral AFM Thermal-Sader method was found to be 8–29% smaller than those obtained from the other two methods. This discrepancy decreased to 3–19% when the torsional mode correction factor for an ideal cantilever was used, which suggests that the torsional mode correction should be taken into account to establish confidence in Lateral AFM Thermal-Sader method. - Highlights: • Quantitative assessment of three lateral force calibration methods for AFM. • Advantages and disadvantages of three different lateral force calibration method. • Implementation of Multi-Load Pivot method as non-contact calibration technique. • The torsional mode correction for Lateral AFM Thermal-Sader method.

  3. Learning from Science and Sport - How we, Safety, "Engage with Rigor"

    Science.gov (United States)

    Herd, A.

    2012-01-01

    As the world of spaceflight safety is relatively small and potentially inward-looking, we need to be aware of the "outside world". We should then try to remind ourselves to be open to the possibility that data, knowledge or experience from outside of the spaceflight community may provide some constructive alternate perspectives. This paper will assess aspects from two seemingly tangential fields, science and sport, and align these with the world of safety. In doing so some useful insights will be given to the challenges we face and may provide solutions relevant in our everyday (of safety engineering). Sport, particularly a contact sport such as rugby union, requires direct interaction between members of two (opposing) teams. Professional, accurately timed and positioned interaction for a desired outcome. These interactions, whilst an essential part of the game, are however not without their constraints. The rugby scrum has constraints as to the formation and engagement of the two teams. The controlled engagement provides for an interaction between the two teams in a safe manner. The constraints arising from the reality that an incorrect engagement could cause serious injury to members of either team. In academia, scientific rigor is applied to assure that the arguments provided and the conclusions drawn in academic papers presented for publication are valid, legitimate and credible. The scientific goal of the need for rigor may be expressed in the example of achieving a statistically relevant sample size, n, in order to assure analysis validity of the data pool. A failure to apply rigor could then place the entire study at risk of failing to have the respective paper published. This paper will consider the merits of these two different aspects, scientific rigor and sports engagement, and offer a reflective look at how this may provide a "modus operandi" for safety engineers at any level whether at their desks (creating or reviewing safety assessments) or in a

  4. Rigorous spin-spin correlation function of Ising model on a special kind of Sierpinski Carpets

    International Nuclear Information System (INIS)

    Yang, Z.R.

    1993-10-01

    We have exactly calculated the rigorous spin-spin correlation function of Ising model on a special kind of Sierpinski Carpets (SC's) by means of graph expansion and a combinatorial approach and investigated the asymptotic behaviour in the limit of long distance. The result show there is no long range correlation between spins at any finite temperature which indicates no existence of phase transition and thus finally confirms the conclusion produced by the renormalization group method and other physical arguments. (author). 7 refs, 6 figs

  5. Quantitative Research Methods in Chaos and Complexity: From Probability to Post Hoc Regression Analyses

    Science.gov (United States)

    Gilstrap, Donald L.

    2013-01-01

    In addition to qualitative methods presented in chaos and complexity theories in educational research, this article addresses quantitative methods that may show potential for future research studies. Although much in the social and behavioral sciences literature has focused on computer simulations, this article explores current chaos and…

  6. Differential rigor development in red and white muscle revealed by simultaneous measurement of tension and stiffness.

    Science.gov (United States)

    Kobayashi, Masahiko; Takemori, Shigeru; Yamaguchi, Maki

    2004-02-10

    Based on the molecular mechanism of rigor mortis, we have proposed that stiffness (elastic modulus evaluated with tension response against minute length perturbations) can be a suitable index of post-mortem rigidity in skeletal muscle. To trace the developmental process of rigor mortis, we measured stiffness and tension in both red and white rat skeletal muscle kept in liquid paraffin at 37 and 25 degrees C. White muscle (in which type IIB fibres predominate) developed stiffness and tension significantly more slowly than red muscle, except for soleus red muscle at 25 degrees C, which showed disproportionately slow rigor development. In each of the examined muscles, stiffness and tension developed more slowly at 25 degrees C than at 37 degrees C. In each specimen, tension always reached its maximum level earlier than stiffness, and then decreased more rapidly and markedly than stiffness. These phenomena may account for the sequential progress of rigor mortis in human cadavers.

  7. Development of a quantitative safety assessment method for nuclear I and C systems including human operators

    International Nuclear Information System (INIS)

    Kim, Man Cheol

    2004-02-01

    Conventional PSA (probabilistic safety analysis) is performed in the framework of event tree analysis and fault tree analysis. In conventional PSA, I and C systems and human operators are assumed to be independent for simplicity. But, the dependency of human operators on I and C systems and the dependency of I and C systems on human operators are gradually recognized to be significant. I believe that it is time to consider the interdependency between I and C systems and human operators in the framework of PSA. But, unfortunately it seems that we do not have appropriate methods for incorporating the interdependency between I and C systems and human operators in the framework of Pasa. Conventional human reliability analysis (HRA) methods are not developed to consider the interdependecy, and the modeling of the interdependency using conventional event tree analysis and fault tree analysis seem to be, event though is does not seem to be impossible, quite complex. To incorporate the interdependency between I and C systems and human operators, we need a new method for HRA and a new method for modeling the I and C systems, man-machine interface (MMI), and human operators for quantitative safety assessment. As a new method for modeling the I and C systems, MMI and human operators, I develop a new system reliability analysis method, reliability graph with general gates (RGGG), which can substitute conventional fault tree analysis. RGGG is an intuitive and easy-to-use method for system reliability analysis, while as powerful as conventional fault tree analysis. To demonstrate the usefulness of the RGGG method, it is applied to the reliability analysis of Digital Plant Protection System (DPPS), which is the actual plant protection system of Ulchin 5 and 6 nuclear power plants located in Republic of Korea. The latest version of the fault tree for DPPS, which is developed by the Integrated Safety Assessment team in Korea Atomic Energy Research Institute (KAERI), consists of 64

  8. A Framework for Rigorously Identifying Research Gaps in Qualitative Literature Reviews

    DEFF Research Database (Denmark)

    Müller-Bloch, Christoph; Kranz, Johann

    2015-01-01

    Identifying research gaps is a fundamental goal of literature reviewing. While it is widely acknowledged that literature reviews should identify research gaps, there are no methodological guidelines for how to identify research gaps in qualitative literature reviews ensuring rigor and replicability....... Our study addresses this gap and proposes a framework that should help scholars in this endeavor without stifling creativity. To develop the framework we thoroughly analyze the state-of-the-art procedure of identifying research gaps in 40 recent literature reviews using a grounded theory approach....... Based on the data, we subsequently derive a framework for identifying research gaps in qualitative literature reviews and demonstrate its application with an example. Our results provide a modus operandi for identifying research gaps, thus enabling scholars to conduct literature reviews more rigorously...

  9. A rigorous test for a new conceptual model for collisions

    International Nuclear Information System (INIS)

    Peixoto, E.M.A.; Mu-Tao, L.

    1979-01-01

    A rigorous theoretical foundation for the previously proposed model is formulated and applied to electron scattering by H 2 in the gas phase. An rigorous treatment of the interaction potential between the incident electron and the Hydrogen molecule is carried out to calculate Differential Cross Sections for 1 KeV electrons, using Glauber's approximation Wang's molecular wave function for the ground electronic state of H 2 . Moreover, it is shown for the first time that, when adequately done, the omission of two center terms does not adversely influence the results of molecular calculations. It is shown that the new model is far superior to the Independent Atom Model (or Independent Particle Model). The accuracy and simplicity of the new model suggest that it may be fruitfully applied to the description of other collision phenomena (e.g., in molecular beam experiments and nuclear physics). A new techniques is presented for calculations involving two center integrals within the frame work of the Glauber's approximation for scattering. (Author) [pt

  10. Rigorous Analysis of a Randomised Number Field Sieve

    OpenAIRE

    Lee, Jonathan; Venkatesan, Ramarathnam

    2018-01-01

    Factorisation of integers $n$ is of number theoretic and cryptographic significance. The Number Field Sieve (NFS) introduced circa 1990, is still the state of the art algorithm, but no rigorous proof that it halts or generates relationships is known. We propose and analyse an explicitly randomised variant. For each $n$, we show that these randomised variants of the NFS and Coppersmith's multiple polynomial sieve find congruences of squares in expected times matching the best-known heuristic e...

  11. A quantitative method to analyse an open answer questionnaire: A case study about the Boltzmann Factor

    International Nuclear Information System (INIS)

    Battaglia, Onofrio Rosario; Di Paola, Benedetto

    2015-01-01

    This paper describes a quantitative method to analyse an openended questionnaire. Student responses to a specially designed written questionnaire are quantitatively analysed by not hierarchical clustering called k-means method. Through this we can characterise behaviour students with respect their expertise to formulate explanations for phenomena or processes and/or use a given model in the different context. The physics topic is about the Boltzmann Factor, which allows the students to have a unifying view of different phenomena in different contexts.

  12. Semi-physical Simulation of the Airborne InSAR based on Rigorous Geometric Model and Real Navigation Data

    Science.gov (United States)

    Changyong, Dou; Huadong, Guo; Chunming, Han; yuquan, Liu; Xijuan, Yue; Yinghui, Zhao

    2014-03-01

    Raw signal simulation is a useful tool for the system design, mission planning, processing algorithm testing, and inversion algorithm design of Synthetic Aperture Radar (SAR). Due to the wide and high frequent variation of aircraft's trajectory and attitude, and the low accuracy of the Position and Orientation System (POS)'s recording data, it's difficult to quantitatively study the sensitivity of the key parameters, i.e., the baseline length and inclination, absolute phase and the orientation of the antennas etc., of the airborne Interferometric SAR (InSAR) system, resulting in challenges for its applications. Furthermore, the imprecise estimation of the installation offset between the Global Positioning System (GPS), Inertial Measurement Unit (IMU) and the InSAR antennas compounds the issue. An airborne interferometric SAR (InSAR) simulation based on the rigorous geometric model and real navigation data is proposed in this paper, providing a way for quantitatively studying the key parameters and for evaluating the effect from the parameters on the applications of airborne InSAR, as photogrammetric mapping, high-resolution Digital Elevation Model (DEM) generation, and surface deformation by Differential InSAR technology, etc. The simulation can also provide reference for the optimal design of the InSAR system and the improvement of InSAR data processing technologies such as motion compensation, imaging, image co-registration, and application parameter retrieval, etc.

  13. Semi-physical Simulation of the Airborne InSAR based on Rigorous Geometric Model and Real Navigation Data

    International Nuclear Information System (INIS)

    Changyong, Dou; Huadong, Guo; Chunming, Han; Yuquan, Liu; Xijuan, Yue; Yinghui, Zhao

    2014-01-01

    Raw signal simulation is a useful tool for the system design, mission planning, processing algorithm testing, and inversion algorithm design of Synthetic Aperture Radar (SAR). Due to the wide and high frequent variation of aircraft's trajectory and attitude, and the low accuracy of the Position and Orientation System (POS)'s recording data, it's difficult to quantitatively study the sensitivity of the key parameters, i.e., the baseline length and inclination, absolute phase and the orientation of the antennas etc., of the airborne Interferometric SAR (InSAR) system, resulting in challenges for its applications. Furthermore, the imprecise estimation of the installation offset between the Global Positioning System (GPS), Inertial Measurement Unit (IMU) and the InSAR antennas compounds the issue. An airborne interferometric SAR (InSAR) simulation based on the rigorous geometric model and real navigation data is proposed in this paper, providing a way for quantitatively studying the key parameters and for evaluating the effect from the parameters on the applications of airborne InSAR, as photogrammetric mapping, high-resolution Digital Elevation Model (DEM) generation, and surface deformation by Differential InSAR technology, etc. The simulation can also provide reference for the optimal design of the InSAR system and the improvement of InSAR data processing technologies such as motion compensation, imaging, image co-registration, and application parameter retrieval, etc

  14. Nuclear medicine and imaging research. Instrumentation and quantitative methods of evaluation. Progress report, January 15, 1984-January 14, 1985

    International Nuclear Information System (INIS)

    Beck, R.N.; Cooper, M.D.

    1984-09-01

    This program addresses problems involving the basic science and technology of radioactive tracer methods as they relate to nuclear medicine and imaging. The broad goal is to develop new instruments and methods for image formation, processing, quantitation and display, so as to maximize the diagnostic information per unit of absorbed radiation dose to the patient. Project I addresses problems associated with the quantitative imaging of single-photon emitters; Project II addresses similar problems associated with the quantitative imaging of positron emitters; Project III addresses methodological problems associated with the quantitative evaluation of the efficacy of diagnostic imaging procedures

  15. Method of quantitative x-ray diffractometric analysis of Ta-Ta2C system

    International Nuclear Information System (INIS)

    Gavrish, A.A.; Glazunov, M.P.; Korolev, Yu.M.; Spitsyn, V.I.; Fedoseev, G.K.

    1976-01-01

    The syste86 Ta-Ta 2 C has beemonsidered because of specific features of diffraction patterns of the components, namely, overlapping of the most intensive reflexes of both phases. The method of standard binary system has been used for quantitative analysis. Because of overlapping of the intensive reflexes dsub(1/01)=2.36(Ta 2 C) and dsub(110)=2.33(Ta), the other, most intensive, reflexes have been used for quantitative determination of Ta 2 C and Ta: dsub(103)=1.404 A for tantalum subcarbide and dsub(211)=1.35A for tantalum. Besides, the TaTa 2 C phases have been determined quantitatively with the use of another pair of reflexes: dsub(102)=1.82 A for Ta 2 C and dsub(200)=1.65 A for tantalum. The agreement between the results obtained while performing the quantitative phase analysis is good. To increase reliability and accuracy of the quantitative determination of Ta and Ta 2 C, it is expedient to carry out the analysis with the use of two above-mentioned pairs of reflexes located in different regions of the diffraction spectrum. Thus, the procedure of quantitative analysis of Ta and Ta 2 C in different ratios has been developed taking into account the specific features of the diffraction patterns of these components as well as the ability of Ta 2 C to texture in the process of preparation

  16. Examining Elementary Preservice Teachers’ Self-Efficacy Beliefs: Combination of Quantitative and Qualitative Methods

    Directory of Open Access Journals (Sweden)

    Çiğdem ŞAHİN-TAŞKIN

    2010-04-01

    Full Text Available This study examines elementary preservice teachers’ self-efficacy beliefs. Quantitative and qualitative research methods were used in this study. In the quantitative part, data were collected from 122 final year preservice teachers. The instrument developed by Tschannen–Moran and Woolfolk–Hoy (2001 was administered to preservice teachers. Findings of the quantitative part revealed that preservice teachers’ self-efficacy towards teaching profession was not fully adequate. There were no differences amongst preservice teachers’ self-efficacy towards teaching regarding gender and achievement. In the qualitative part of the study, preservice teachers responded to factors involving Student Engagement and Classroom Management based on experiences that they gained in teaching practice. However, their explanation relied on their theoretical knowledge regarding the Instructional Strategies factor. This could be explained as they have lack of experiences regarding this factor

  17. Dual respiratory and cardiac motion estimation in PET imaging: Methods design and quantitative evaluation.

    Science.gov (United States)

    Feng, Tao; Wang, Jizhe; Tsui, Benjamin M W

    2018-04-01

    The goal of this study was to develop and evaluate four post-reconstruction respiratory and cardiac (R&C) motion vector field (MVF) estimation methods for cardiac 4D PET data. In Method 1, the dual R&C motions were estimated directly from the dual R&C gated images. In Method 2, respiratory motion (RM) and cardiac motion (CM) were separately estimated from the respiratory gated only and cardiac gated only images. The effects of RM on CM estimation were modeled in Method 3 by applying an image-based RM correction on the cardiac gated images before CM estimation, the effects of CM on RM estimation were neglected. Method 4 iteratively models the mutual effects of RM and CM during dual R&C motion estimations. Realistic simulation data were generated for quantitative evaluation of four methods. Almost noise-free PET projection data were generated from the 4D XCAT phantom with realistic R&C MVF using Monte Carlo simulation. Poisson noise was added to the scaled projection data to generate additional datasets of two more different noise levels. All the projection data were reconstructed using a 4D image reconstruction method to obtain dual R&C gated images. The four dual R&C MVF estimation methods were applied to the dual R&C gated images and the accuracy of motion estimation was quantitatively evaluated using the root mean square error (RMSE) of the estimated MVFs. Results show that among the four estimation methods, Methods 2 performed the worst for noise-free case while Method 1 performed the worst for noisy cases in terms of quantitative accuracy of the estimated MVF. Methods 4 and 3 showed comparable results and achieved RMSE lower by up to 35% than that in Method 1 for noisy cases. In conclusion, we have developed and evaluated 4 different post-reconstruction R&C MVF estimation methods for use in 4D PET imaging. Comparison of the performance of four methods on simulated data indicates separate R&C estimation with modeling of RM before CM estimation (Method 3) to be

  18. Quali-quantitative analysis (QQA): why it could open new frontiers for holistic health practice.

    Science.gov (United States)

    Bell, Erica

    2006-12-15

    Holistic health practice is often described as being about understanding the larger contexts of patients, their health services, and their communities. Yet do traditional quantitative and qualitative health research methods produce the best possible evidence for the holistic practices of doctors, nurses, and allied health professionals? This paper argues "no", and examines the potential of a cutting-edge, social science research method--Quali-Quantitative Research (QQA)--for providing better evidence for holistic practice, particularly in small-N populations, such as rural and remote communities. It does so with reference to the international literature on holistic medicine, as well as three holistic health projects conducted in Tasmania: about prevention of falls in older people, adolescent substance abuse, and interventions for children aged 0-5 exposed to domestic violence. The findings suggest that much health research fails to capture rigorously the contextual complexity of holistic health challenges: the multiple different needs of individual patients, and the interprofessional approaches needed to deliver multidisciplinary and multiservice health interventions tailored to meet those needs in particular community contexts. QQA offers a "configurational", case-based, diversity-oriented approach to analysing data that combines qualitative and quantitative techniques to overcome the limitations of both research traditions. The author concludes that QQA could open new frontiers for holistic health by helping doctors, nurses, and allied health professionals answer a fundamental question presented by complex health challenges: "Given this set of whole-of-patient needs, what elements of which interventions in what services would work best in this particular community?"

  19. Qualitative and quantitative methods for human factor analysis and assessment in NPP. Investigations and results

    International Nuclear Information System (INIS)

    Hristova, R.; Kalchev, B.; Atanasov, D.

    2005-01-01

    We consider here two basic groups of methods for analysis and assessment of the human factor in the NPP area and give some results from performed analyses as well. The human factor is the human interaction with the design equipment, with the working environment and takes into account the human capabilities and limits. In the frame of the qualitative methods for analysis of the human factor are considered concepts and structural methods for classifying of the information, connected with the human factor. Emphasize is given to the HPES method for human factor analysis in NPP. Methods for quantitative assessment of the human reliability are considered. These methods allow assigning of probabilities to the elements of the already structured information about human performance. This part includes overview of classical methods for human reliability assessment (HRA, THERP), and methods taking into account specific information about human capabilities and limits and about the man-machine interface (CHR, HEART, ATHEANA). Quantitative and qualitative results concerning human factor influence in the initiating events occurrences in the Kozloduy NPP are presented. (authors)

  20. Quantitative phosphoproteomic analysis of caprine muscle with high and low meat quality.

    Science.gov (United States)

    Liu, Manshun; Wei, Yanchao; Li, Xin; Quek, Siew Young; Zhao, Jing; Zhong, Huazhen; Zhang, Dequan; Liu, Yongfeng

    2018-07-01

    During the conversion of muscle to meat, protein phosphorylation can regulate various biological processes that have important effects on meat quality. To investigate the phosphorylation pattern of protein on rigor mortis, goat longissimus thoracis and external intercostals were classified into two groups (high quality and low quality), and meat quality was evaluated according to meat quality attributes (Warner-Bratzler shear force, Color, pH and drip loss). A quantitative mass spectrometry-based phosphoproteomic study was conducted to analyze the caprine muscle at 12h postmortem applying the TiO 2 -SIMAC-HILIC (TiSH) phosphopeptide enrichment strategy. A total of 2125 phosphopeptides were identified from 750 phosphoproteins. Among them, 96 proteins had differed in phosphorylation levels. The majority of these proteins are involved in glucose metabolism and muscle contraction. The differential phosphorylation level of proteins (PFK, MYL2 and HSP27) in two groups may be the crucial factors of regulating muscle rigor mortis. This study provides a comprehensive view for the phosphorylation status of caprine muscle at rigor mortis, it also gives a better understanding of the regulation of protein phosphorylation on various biological processes that affect the final meat quality attributes. Copyright © 2018. Published by Elsevier Ltd.

  1. A Stereological Method for the Quantitative Evaluation of Cartilage Repair Tissue

    Science.gov (United States)

    Nyengaard, Jens Randel; Lind, Martin; Spector, Myron

    2015-01-01

    Objective To implement stereological principles to develop an easy applicable algorithm for unbiased and quantitative evaluation of cartilage repair. Design Design-unbiased sampling was performed by systematically sectioning the defect perpendicular to the joint surface in parallel planes providing 7 to 10 hematoxylin–eosin stained histological sections. Counting windows were systematically selected and converted into image files (40-50 per defect). The quantification was performed by two-step point counting: (1) calculation of defect volume and (2) quantitative analysis of tissue composition. Step 2 was performed by assigning each point to one of the following categories based on validated and easy distinguishable morphological characteristics: (1) hyaline cartilage (rounded cells in lacunae in hyaline matrix), (2) fibrocartilage (rounded cells in lacunae in fibrous matrix), (3) fibrous tissue (elongated cells in fibrous tissue), (4) bone, (5) scaffold material, and (6) others. The ability to discriminate between the tissue types was determined using conventional or polarized light microscopy, and the interobserver variability was evaluated. Results We describe the application of the stereological method. In the example, we assessed the defect repair tissue volume to be 4.4 mm3 (CE = 0.01). The tissue fractions were subsequently evaluated. Polarized light illumination of the slides improved discrimination between hyaline cartilage and fibrocartilage and increased the interobserver agreement compared with conventional transmitted light. Conclusion We have applied a design-unbiased method for quantitative evaluation of cartilage repair, and we propose this algorithm as a natural supplement to existing descriptive semiquantitative scoring systems. We also propose that polarized light is effective for discrimination between hyaline cartilage and fibrocartilage. PMID:26069715

  2. Quantitative Risk Analysis: Method And Process

    Directory of Open Access Journals (Sweden)

    Anass BAYAGA

    2010-03-01

    Full Text Available Recent and past studies (King III report, 2009: 73-75; Stoney 2007;Committee of Sponsoring Organisation-COSO, 2004, Bartell, 2003; Liebenberg and Hoyt, 2003; Reason, 2000; Markowitz 1957 lament that although, the introduction of quantifying risk to enhance degree of objectivity in finance for instance was quite parallel to its development in the manufacturing industry, it is not the same in Higher Education Institution (HEI. In this regard, the objective of the paper was to demonstrate the methods and process of Quantitative Risk Analysis (QRA through likelihood of occurrence of risk (phase I. This paper serves as first of a two-phased study, which sampled hundred (100 risk analysts in a University in the greater Eastern Cape Province of South Africa.The analysis of likelihood of occurrence of risk by logistic regression and percentages were conducted to investigate whether there were a significant difference or not between groups (analyst in respect of QRA.The Hosmer and Lemeshow test was non-significant with a chi-square(X2 =8.181; p = 0.300, which indicated that there was a good model fit, since the data did not significantly deviate from the model. The study concluded that to derive an overall likelihood rating that indicated the probability that a potential risk may be exercised within the construct of an associated threat environment, the following governing factors must be considered: (1 threat source motivation and capability (2 nature of the vulnerability (3 existence and effectiveness of current controls (methods and process.

  3. Effect of pre-rigor stretch and various constant temperatures on the rate of post-mortem pH fall, rigor mortis and some quality traits of excised porcine biceps femoris muscle strips.

    Science.gov (United States)

    Vada-Kovács, M

    1996-01-01

    Porcine biceps femoris strips of 10 cm original length were stretched by 50% and fixed within 1 hr post mortem then subjected to temperatures of 4 °, 15 ° or 36 °C until they attained their ultimate pH. Unrestrained control muscle strips, which were left to shorten freely, were similarly treated. Post-mortem metabolism (pH, R-value) and shortening were recorded; thereafter ultimate meat quality traits (pH, lightness, extraction and swelling of myofibrils) were determined. The rate of pH fall at 36 °C, as well as ATP breakdown at 36 and 4 °C, were significantly reduced by pre-rigor stretch. The relationship between R-value and pH indicated cold shortening at 4 °C. Myofibrils isolated from pre-rigor stretched muscle strips kept at 36 °C showed the most severe reduction of hydration capacity, while paleness remained below extreme values. However, pre-rigor stretched myofibrils - when stored at 4 °C - proved to be superior to shortened ones in their extractability and swelling.

  4. Are three generations of quantitative molecular methods sufficient in medical virology? Brief review.

    Science.gov (United States)

    Clementi, Massimo; Bagnarelli, Patrizia

    2015-10-01

    In the last two decades, development of quantitative molecular methods has characterized the evolution of clinical virology more than any other methodological advancement. Using these methods, a great deal of studies has addressed efficiently in vivo the role of viral load, viral replication activity, and viral transcriptional profiles as correlates of disease outcome and progression, and has highlighted the physio-pathology of important virus diseases of humans. Furthermore, these studies have contributed to a better understanding of virus-host interactions and have sharply revolutionized the research strategies in basic and medical virology. In addition and importantly from a medical point of view, quantitative methods have provided a rationale for the therapeutic intervention and therapy monitoring in medically important viral diseases. Despite the advances in technology and the development of three generations of molecular methods within the last two decades (competitive PCR, real-time PCR, and digital PCR), great challenges still remain for viral testing related not only to standardization, accuracy, and precision, but also to selection of the best molecular targets for clinical use and to the identification of thresholds for risk stratification and therapeutic decisions. Future research directions, novel methods and technical improvements could be important to address these challenges.

  5. Experimental evaluation of rigor mortis IX. The influence of the breaking (mechanical solution) on the development of rigor mortis.

    Science.gov (United States)

    Krompecher, Thomas; Gilles, André; Brandt-Casadevall, Conception; Mangin, Patrice

    2008-04-07

    Objective measurements were carried out to study the possible re-establishment of rigor mortis on rats after "breaking" (mechanical solution). Our experiments showed that: *Cadaveric rigidity can re-establish after breaking. *A significant rigidity can reappear if the breaking occurs before the process is complete. *Rigidity will be considerably weaker after the breaking. *The time course of the intensity does not change in comparison to the controls: --the re-establishment begins immediately after the breaking; --maximal values are reached at the same time as in the controls; --the course of the resolution is the same as in the controls.

  6. Quantitative autoradiography of neurochemicals

    International Nuclear Information System (INIS)

    Rainbow, T.C.; Biegon, A.; Bleisch, W.V.

    1982-01-01

    Several new methods have been developed that apply quantitative autoradiography to neurochemistry. These methods are derived from the 2-deoxyglucose (2DG) technique of Sokoloff (1), which uses quantitative autoradiography to measure the rate of glucose utilization in brain structures. The new methods allow the measurement of the rate of cerbral protein synthesis and the levels of particular neurotransmitter receptors by quantitative autoradiography. As with the 2DG method, the new techniques can measure molecular levels in micron-sized brain structures; and can be used in conjunction with computerized systems of image processing. It is possible that many neurochemical measurements could be made by computerized analysis of quantitative autoradiograms

  7. Quantitative assessment of breast density: comparison of different methods

    International Nuclear Information System (INIS)

    Qin Naishan; Guo Li; Dang Yi; Song Luxin; Wang Xiaoying

    2011-01-01

    Objective: To Compare different methods of quantitative breast density measurement. Methods: The study included sixty patients who underwent both mammography and breast MRI. The breast density was computed automatically on digital mammograms with R2 workstation, Two experienced radiologists read the mammograms and assessed the breast density with Wolfe and ACR classification respectively. Fuzzy C-means clustering algorithm (FCM) was used to assess breast density on MRI. Each assessment method was repeated after 2 weeks. Spearman and Pearson correlations of inter- and intrareader and intermodality were computed for density estimates. Results: Inter- and intrareader correlation of Wolfe classification were 0.74 and 0.65, and they were 0.74 and 0.82 for ACR classification respectively. Correlation between Wolfe and ACR classification was 0.77. High interreader correlation of 0.98 and intrareader correlation of 0.96 was observed with MR FCM measurement. And the correlation between digital mammograms and MRI was high in the assessment of breast density (r=0.81, P<0.01). Conclusion: High correlation of breast density estimates on digital mammograms and MRI FCM suggested the former could be used as a simple and accurate method. (authors)

  8. A rigorous approach to investigating common assumptions about disease transmission: Process algebra as an emerging modelling methodology for epidemiology.

    Science.gov (United States)

    McCaig, Chris; Begon, Mike; Norman, Rachel; Shankland, Carron

    2011-03-01

    Changing scale, for example, the ability to move seamlessly from an individual-based model to a population-based model, is an important problem in many fields. In this paper, we introduce process algebra as a novel solution to this problem in the context of models of infectious disease spread. Process algebra allows us to describe a system in terms of the stochastic behaviour of individuals, and is a technique from computer science. We review the use of process algebra in biological systems, and the variety of quantitative and qualitative analysis techniques available. The analysis illustrated here solves the changing scale problem: from the individual behaviour we can rigorously derive equations to describe the mean behaviour of the system at the level of the population. The biological problem investigated is the transmission of infection, and how this relates to individual interactions.

  9. Validation of quantitative 1H NMR method for the analysis of pharmaceutical formulations

    International Nuclear Information System (INIS)

    Santos, Maiara da S.

    2013-01-01

    The need for effective and reliable quality control in products from pharmaceutical industries renders the analyses of their active ingredients and constituents of great importance. This study presents the theoretical basis of ¹H NMR for quantitative analyses and an example of the method validation according to Resolution RE N. 899 by the Brazilian National Health Surveillance Agency (ANVISA), in which the compound paracetamol was the active ingredient. All evaluated parameters (selectivity, linearity, accuracy, repeatability and robustness) showed satisfactory results. It was concluded that a single NMR measurement provides structural and quantitative information of active components and excipients in the sample. (author)

  10. A novel method for quantitative geosteering using azimuthal gamma-ray logging.

    Science.gov (United States)

    Yuan, Chao; Zhou, Cancan; Zhang, Feng; Hu, Song; Li, Chaoliu

    2015-02-01

    A novel method for quantitative geosteering by using azimuthal gamma-ray logging is proposed. Real-time up and bottom gamma-ray logs when a logging tool travels through a boundary surface with different relative dip angles are simulated with the Monte Carlo method. Study results show that response points of up and bottom gamma-ray logs when the logging tool moves towards a highly radioactive formation can be used to predict the relative dip angle, and then the distance from the drilling bit to the boundary surface is calculated. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Quantitative Methods Intervention: What Do the Students Want?

    Science.gov (United States)

    Frankland, Lianne; Harrison, Jacqui

    2016-01-01

    The shortage of social science graduates with competent quantitative skills jeopardises the competitive UK economy, public policy making effectiveness and the status the UK has as a world leader in higher education and research (British Academy for Humanities and Social Sciences, 2012). There is a growing demand for quantitative skills across all…

  12. Comparison of salivary collection and processing methods for quantitative HHV-8 detection.

    Science.gov (United States)

    Speicher, D J; Johnson, N W

    2014-10-01

    Saliva is a proved diagnostic fluid for the qualitative detection of infectious agents, but the accuracy of viral load determinations is unknown. Stabilising fluids impede nucleic acid degradation, compared with collection onto ice and then freezing, and we have shown that the DNA Genotek P-021 prototype kit (P-021) can produce high-quality DNA after 14 months of storage at room temperature. Here we evaluate the quantitative capability of 10 collection/processing methods. Unstimulated whole mouth fluid was spiked with a mixture of HHV-8 cloned constructs, 10-fold serial dilutions were produced, and samples were extracted and then examined with quantitative PCR (qPCR). Calibration curves were compared by linear regression and qPCR dynamics. All methods extracted with commercial spin columns produced linear calibration curves with large dynamic range and gave accurate viral loads. Ethanol precipitation of the P-021 does not produce a linear standard curve, and virus is lost in the cell pellet. DNA extractions from the P-021 using commercial spin columns produced linear standard curves with wide dynamic range and excellent limit of detection. When extracted with spin columns, the P-021 enables accurate viral loads down to 23 copies μl(-1) DNA. The quantitative and long-term storage capability of this system makes it ideal for study of salivary DNA viruses in resource-poor settings. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Quantitative Methods to Evaluate Timetable Attractiveness

    DEFF Research Database (Denmark)

    Schittenhelm, Bernd; Landex, Alex

    2009-01-01

    The article describes how the attractiveness of timetables can be evaluated quantitatively to ensure a consistent evaluation of timetables. Since the different key stakeholders (infrastructure manager, train operating company, customers, and society) have different opinions on what an attractive...

  14. Quantitative sacroiliac scintigraphy. The effect of method of selection of region of interest

    International Nuclear Information System (INIS)

    Davis, M.C.; Turner, D.A.; Charters, J.R.; Golden, H.E.; Ali, A.; Fordham, E.W.

    1984-01-01

    Various authors have advocated quantitative methods of evaluating bone scintigrams to detect sacroiliitis, while others have not found them useful. Many explanations for this disagreement have been offered, including differences in the method of case selection, ethnicity, gender, and previous drug therapy. It would appear that one of the most important impediments to consistent results is the variability of selecting sacroiliac joint and reference regions of interest (ROIs). The effect of ROI selection would seem particularly important because of the normal variability of radioactivity within the reference regions that have been used (sacrum, spine, iliac wing) and the inhomogeneity of activity in the SI joints. We have investigated the effect of ROI selection, using five different methods representative of, though not necessarily identical to, those found in the literature. Each method produced unique mean indices that were different for patients with ankylosing spondylitis (AS) and controls. The method of Ayres (19) proved superior (largest mean difference, smallest variance), but none worked well as a diagnostic tool because of substantial overlap of the distributions of indices of patient and control groups. We conclude that ROI selection is important in determining results, and quantitative scintigraphic methods in general are not effective tools for diagnosing AS. Among the possible factors limiting success, difficulty in selecting a stable reference area seems of particular importance

  15. A quantitative method for assessing resilience of interdependent infrastructures

    International Nuclear Information System (INIS)

    Nan, Cen; Sansavini, Giovanni

    2017-01-01

    The importance of understanding system resilience and identifying ways to enhance it, especially for interdependent infrastructures our daily life depends on, has been recognized not only by academics, but also by the corporate and public sectors. During recent years, several methods and frameworks have been proposed and developed to explore applicable techniques to assess and analyze system resilience in a comprehensive way. However, they are often tailored to specific disruptive hazards/events, or fail to properly include all the phases such as absorption, adaptation, and recovery. In this paper, a quantitative method for the assessment of the system resilience is proposed. The method consists of two components: an integrated metric for system resilience quantification and a hybrid modeling approach for representing the failure behavior of infrastructure systems. The feasibility and applicability of the proposed method are tested using an electric power supply system as the exemplary infrastructure. Simulation results highlight that the method proves effective in designing, engineering and improving the resilience of infrastructures. Finally, system resilience is proposed as a proxy to quantify the coupling strength between interdependent infrastructures. - Highlights: • A method for quantifying resilience of interdependent infrastructures is proposed. • It combines multi-layer hybrid modeling and a time-dependent resilience metric. • The feasibility of the proposed method is tested on the electric power supply system. • The method provides insights to decision-makers for strengthening system resilience. • Resilience capabilities can be used to engineer interdependencies between subsystems.

  16. The laboratory of quantitative methods in historic monument research at the CTU Prague

    International Nuclear Information System (INIS)

    Musilek, L.; Cechak, T.; Kubelik, M.; Pavelka, K.; Pavlik, M.

    2001-01-01

    A 'Laboratory of Quantitative Methods in Historic Monument Research' has been established at the Department of Dosimetry and Application of Ionizing Radiation of the CTU Prague. Its primary orientation is the investigation of historic architecture, although other objects of art can also be, investigated. In the first phase, one investigative method was established for each of the above groups: X-ray fluorescence as the analytic method, thermoluminescence for dating and photogrammetry for surveying. The first results demonstrate the need and usefulness of these methods for investigations in the rich architectural heritage of the Czech Republic.

  17. Implementation of a quantitative Foucault knife-edge method by means of isophotometry

    Science.gov (United States)

    Zhevlakov, A. P.; Zatsepina, M. E.; Kirillovskii, V. K.

    2014-06-01

    Detailed description of stages of computer processing of the shadowgrams during implementation of a modern quantitative Foucault knife-edge method is presented. The map of wave-front aberrations introduced by errors of an optical surface or a system, along with the results of calculation of the set of required characteristics of image quality, are shown.

  18. Integrating Quantitative and Qualitative Data in Mixed Methods Research--Challenges and Benefits

    Science.gov (United States)

    Almalki, Sami

    2016-01-01

    This paper is concerned with investigating the integration of quantitative and qualitative data in mixed methods research and whether, in spite of its challenges, it can be of positive benefit to many investigative studies. The paper introduces the topic, defines the terms with which this subject deals and undertakes a literature review to outline…

  19. Effects of post mortem temperature on rigor tension, shortening and ...

    African Journals Online (AJOL)

    Fully developed rigor mortis in muscle is characterised by maximum loss of extensibility. The course of post mortem changes in ostrich muscle was studied by following isometric tension, shortening and change in pH during the first 24 h post mortem within muscle strips from the muscularis gastrocnemius, pars interna at ...

  20. Improving statistical inference on pathogen densities estimated by quantitative molecular methods: malaria gametocytaemia as a case study.

    Science.gov (United States)

    Walker, Martin; Basáñez, María-Gloria; Ouédraogo, André Lin; Hermsen, Cornelus; Bousema, Teun; Churcher, Thomas S

    2015-01-16

    Quantitative molecular methods (QMMs) such as quantitative real-time polymerase chain reaction (q-PCR), reverse-transcriptase PCR (qRT-PCR) and quantitative nucleic acid sequence-based amplification (QT-NASBA) are increasingly used to estimate pathogen density in a variety of clinical and epidemiological contexts. These methods are often classified as semi-quantitative, yet estimates of reliability or sensitivity are seldom reported. Here, a statistical framework is developed for assessing the reliability (uncertainty) of pathogen densities estimated using QMMs and the associated diagnostic sensitivity. The method is illustrated with quantification of Plasmodium falciparum gametocytaemia by QT-NASBA. The reliability of pathogen (e.g. gametocyte) densities, and the accompanying diagnostic sensitivity, estimated by two contrasting statistical calibration techniques, are compared; a traditional method and a mixed model Bayesian approach. The latter accounts for statistical dependence of QMM assays run under identical laboratory protocols and permits structural modelling of experimental measurements, allowing precision to vary with pathogen density. Traditional calibration cannot account for inter-assay variability arising from imperfect QMMs and generates estimates of pathogen density that have poor reliability, are variable among assays and inaccurately reflect diagnostic sensitivity. The Bayesian mixed model approach assimilates information from replica QMM assays, improving reliability and inter-assay homogeneity, providing an accurate appraisal of quantitative and diagnostic performance. Bayesian mixed model statistical calibration supersedes traditional techniques in the context of QMM-derived estimates of pathogen density, offering the potential to improve substantially the depth and quality of clinical and epidemiological inference for a wide variety of pathogens.

  1. Comparison of different surface quantitative analysis methods. Application to corium

    International Nuclear Information System (INIS)

    Guilbaud, N.; Blin, D.; Perodeaud, Ph.; Dugne, O.; Gueneau, Ch.

    2000-01-01

    In case of a severe hypothetical accident in a pressurized water reactor, the reactor assembly melts partially or completely. The material formed, called corium, flows out and spreads at the bottom of the reactor. To limit and control the consequences of such an accident, the specifications of the O-U-Zr basic system must be known accurately. To achieve this goal, the corium mix was melted by electron bombardment at very high temperature (3000 K) followed by quenching of the ingot in the Isabel 1 evaporator. Metallographic analyses were then required to validate the thermodynamic databases set by the Thermo-Calc software. The study consists in defining an overall surface quantitative analysis method that is fast and reliable, in order to determine the overall corium composition. The analyzed ingot originated in a [U+Fe+Y+UO 2 +ZrO 2 ) mix, with a total mass of 2253.7 grams. Several successive heating with average power were performed before a very brief plateau at very high temperature, so that the ingot was formed progressively and without any evaporation liable to modify its initial composition. The central zone of the ingot was then analyzed by qualitative and quantitative global surface methods, to yield the volume composition of the analyzed zone. Corium sample analysis happens to be very complex because of the variety and number of elements present, and also because of the presence of oxygen in a heavy element like the uranium based matrix. Three different global quantitative surface analysis methods were used: global EDS analysis (Energy Dispersive Spectrometry), with SEM, global WDS analysis (Wavelength Dispersive Spectrometry) with EPMA, and coupling of image analysis with EDS or WDS point spectroscopic analyses. The difficulties encountered during the study arose from sample preparation (corium is very sensitive to oxidation), and the choice of acquisition parameters of the images and analyses. The corium sample studied consisted of two zones displaying

  2. New 'ex vivo' radioisotopic method of quantitation of platelet deposition

    International Nuclear Information System (INIS)

    Badimon, L.; Mayo Clinic, Rochester, MN; Thrombosis and Atherosclerosis Unit, Barcelona; Mayo Clinic, Rochester, MN; Fuster, V.; Chesebro, J.H.; Dewanjee, M.K.

    1983-01-01

    We have developed a sensitive and quantitative method of 'ex vivo' evaluation of platelet deposition on collagen strips, from rabbit Achilles tendon, superfused by flowing blood and applied it to four animal species, cat, rabbit, dog and pig. Autologous platelets were labeled with indium-111-tropolone, injected to the animal 24 hr before the superfusion and the number of deposited platelets was quantitated from the tendon gamma-radiation and the blood platelet count. We detected some platelet consumption with superfusion time when blood was reinfused entering the contralateral jugular vein after collagen contact but not if blood was discarded after the contact. Therefore, in order to have a more physiological animal model we decided to discard blood after superfusion of the tendon. In all species except for the cat there was a linear relationship between increase of platelet on the tendon and time of exposure to blood superfusion. The highest number of platelets deposited on the collagen was found in cats, the lowest in dogs. Ultrastructural analysis showed the platelets were deposited as aggregates after only 5 min of superfusion. (orig.)

  3. Pre-rigor temperature and the relationship between lamb tenderisation, free water production, bound water and dry matter.

    Science.gov (United States)

    Devine, Carrick; Wells, Robyn; Lowe, Tim; Waller, John

    2014-01-01

    The M. longissimus from lambs electrically stimulated at 15 min post-mortem were removed after grading, wrapped in polythene film and held at 4 (n=6), 7 (n=6), 15 (n=6, n=8) and 35°C (n=6), until rigor mortis then aged at 15°C for 0, 4, 24 and 72 h post-rigor. Centrifuged free water increased exponentially, and bound water, dry matter and shear force decreased exponentially over time. Decreases in shear force and increases in free water were closely related (r(2)=0.52) and were unaffected by pre-rigor temperatures. © 2013.

  4. The development of quantitative determination method of organic acids in complex poly herbal extraction

    Directory of Open Access Journals (Sweden)

    I. L. Dyachok

    2016-08-01

    Full Text Available Aim. The development of sensible, economical and expressive method of quantitative determination of organic acids in complex poly herbal extraction counted on izovaleric acid with the use of digital technologies. Materials and methods. Model complex poly herbal extraction of sedative action was chosen as a research object. Extraction is composed of these medical plants: Valeriana officinalis L., Crataégus, Melissa officinalis L., Hypericum, Mentha piperita L., Húmulus lúpulus, Viburnum. Based on chemical composition of plant components, we consider that main pharmacologically active compounds, which can be found in complex poly herbal extraction are: polyphenolic substances (flavonoids, which are contained in Crataégus, Viburnum, Hypericum, Mentha piperita L., Húmulus lúpulus; also organic acids, including izovaleric acid, which are contained in Valeriana officinalis L., Mentha piperita L., Melissa officinalis L., Viburnum; the aminoacid are contained in Valeriana officinalis L. For the determination of organic acids content in low concentration we applied instrumental method of analysis, namely conductometry titration which consisted in the dependences of water solution conductivity of complex poly herbal extraction on composition of organic acids. Result. The got analytical dependences, which describes tangent lines to the conductometry curve before and after the point of equivalence, allow to determine the volume of solution expended on titration and carry out procedure of quantitative determination of organic acids in the digital mode. Conclusion. The proposed method enables to determine the point of equivalence and carry out quantitative determination of organic acids counted on izovaleric acid with the use of digital technologies, that allows to computerize the method on the whole.

  5. New rigorous asymptotic theorems for inverse scattering amplitudes

    International Nuclear Information System (INIS)

    Lomsadze, Sh.Yu.; Lomsadze, Yu.M.

    1984-01-01

    The rigorous asymptotic theorems both of integral and local types obtained earlier and establishing logarithmic and in some cases even power correlations aetdeen the real and imaginary parts of scattering amplitudes Fsub(+-) are extended to the inverse amplitudes 1/Fsub(+-). One also succeeds in establishing power correlations of a new type between the real and imaginary parts, both for the amplitudes themselves and for the inverse ones. All the obtained assertions are convenient to be tested in high energy experiments when the amplitudes show asymptotic behaviour

  6. Quantitative methods of data analysis for the physical sciences and engineering

    CERN Document Server

    Martinson, Douglas G

    2018-01-01

    This book provides thorough and comprehensive coverage of most of the new and important quantitative methods of data analysis for graduate students and practitioners. In recent years, data analysis methods have exploded alongside advanced computing power, and it is critical to understand such methods to get the most out of data, and to extract signal from noise. The book excels in explaining difficult concepts through simple explanations and detailed explanatory illustrations. Most unique is the focus on confidence limits for power spectra and their proper interpretation, something rare or completely missing in other books. Likewise, there is a thorough discussion of how to assess uncertainty via use of Expectancy, and the easy to apply and understand Bootstrap method. The book is written so that descriptions of each method are as self-contained as possible. Many examples are presented to clarify interpretations, as are user tips in highlighted boxes.

  7. Double phosphorylation of the myosin regulatory light chain during rigor mortis of bovine Longissimus muscle.

    Science.gov (United States)

    Muroya, Susumu; Ohnishi-Kameyama, Mayumi; Oe, Mika; Nakajima, Ikuyo; Shibata, Masahiro; Chikuni, Koichi

    2007-05-16

    To investigate changes in myosin light chains (MyLCs) during postmortem aging of the bovine longissimus muscle, we performed two-dimensional gel electrophoresis followed by identification with matrix-assisted laser desorption ionization time-of-flight mass spectrometry. The results of fluorescent differential gel electrophoresis showed that two spots of the myosin regulatory light chain (MyLC2) at pI values of 4.6 and 4.7 shifted toward those at pI values of 4.5 and 4.6, respectively, by 24 h postmortem when rigor mortis was completed. Meanwhile, the MyLC1 and MyLC3 spots did not change during the 14 days postmortem. Phosphoprotein-specific staining of the gels demonstrated that the MyLC2 proteins at pI values of 4.5 and 4.6 were phosphorylated. Furthermore, possible N-terminal region peptides containing one and two phosphoserine residues were detected in each mass spectrum of the MyLC2 spots at pI values of 4.5 and 4.6, respectively. These results demonstrated that MyLC2 became doubly phosphorylated during rigor formation of the bovine longissimus, suggesting involvement of the MyLC2 phosphorylation in the progress of beef rigor mortis. Bovine; myosin regulatory light chain (RLC, MyLC2); phosphorylation; rigor mortis; skeletal muscle.

  8. Quantitative comparison of analysis methods for spectroscopic optical coherence tomography: reply to comment

    NARCIS (Netherlands)

    Bosschaart, Nienke; van Leeuwen, Ton; Aalders, Maurice C.G.; Faber, Dirk

    2014-01-01

    We reply to the comment by Kraszewski et al on “Quantitative comparison of analysis methods for spectroscopic optical coherence tomography.” We present additional simulations evaluating the proposed window function. We conclude that our simulations show good qualitative agreement with the results of

  9. Study Design Rigor in Animal-Experimental Research Published in Anesthesia Journals.

    Science.gov (United States)

    Hoerauf, Janine M; Moss, Angela F; Fernandez-Bustamante, Ana; Bartels, Karsten

    2018-01-01

    Lack of reproducibility of preclinical studies has been identified as an impediment for translation of basic mechanistic research into effective clinical therapies. Indeed, the National Institutes of Health has revised its grant application process to require more rigorous study design, including sample size calculations, blinding procedures, and randomization steps. We hypothesized that the reporting of such metrics of study design rigor has increased over time for animal-experimental research published in anesthesia journals. PubMed was searched for animal-experimental studies published in 2005, 2010, and 2015 in primarily English-language anesthesia journals. A total of 1466 publications were graded on the performance of sample size estimation, randomization, and blinding. Cochran-Armitage test was used to assess linear trends over time for the primary outcome of whether or not a metric was reported. Interrater agreement for each of the 3 metrics (power, randomization, and blinding) was assessed using the weighted κ coefficient in a 10% random sample of articles rerated by a second investigator blinded to the ratings of the first investigator. A total of 1466 manuscripts were analyzed. Reporting for all 3 metrics of experimental design rigor increased over time (2005 to 2010 to 2015): for power analysis, from 5% (27/516), to 12% (59/485), to 17% (77/465); for randomization, from 41% (213/516), to 50% (243/485), to 54% (253/465); and for blinding, from 26% (135/516), to 38% (186/485), to 47% (217/465). The weighted κ coefficients and 98.3% confidence interval indicate almost perfect agreement between the 2 raters beyond that which occurs by chance alone (power, 0.93 [0.85, 1.0], randomization, 0.91 [0.85, 0.98], and blinding, 0.90 [0.84, 0.96]). Our hypothesis that reported metrics of rigor in animal-experimental studies in anesthesia journals have increased during the past decade was confirmed. More consistent reporting, or explicit justification for absence

  10. Can You Repeat That Please?: Using Monte Carlo Simulation in Graduate Quantitative Research Methods Classes

    Science.gov (United States)

    Carsey, Thomas M.; Harden, Jeffrey J.

    2015-01-01

    Graduate students in political science come to the discipline interested in exploring important political questions, such as "What causes war?" or "What policies promote economic growth?" However, they typically do not arrive prepared to address those questions using quantitative methods. Graduate methods instructors must…

  11. Qualitative Methods Can Enrich Quantitative Research on Occupational Stress: An Example from One Occupational Group

    Science.gov (United States)

    Schonfeld, Irvin Sam; Farrell, Edwin

    2010-01-01

    The chapter examines the ways in which qualitative and quantitative methods support each other in research on occupational stress. Qualitative methods include eliciting from workers unconstrained descriptions of work experiences, careful first-hand observations of the workplace, and participant-observers describing "from the inside" a…

  12. Quantitative analysis of γ–oryzanol content in cold pressed rice bran oil by TLC–image analysis method

    Directory of Open Access Journals (Sweden)

    Apirak Sakunpak

    2014-02-01

    Conclusions: The TLC-densitometric and TLC-image analysis methods provided a similar reproducibility, accuracy and selectivity for the quantitative determination of γ-oryzanol in cold pressed rice bran oil. A statistical comparison of the quantitative determinations of γ-oryzanol in samples did not show any statistically significant difference between TLC-densitometric and TLC-image analysis methods. As both methods were found to be equal, they therefore can be used for the determination of γ-oryzanol in cold pressed rice bran oil.

  13. Qualitative and quantitative determination of ubiquinones by the method of high-efficiency liquid chromatography

    International Nuclear Information System (INIS)

    Yanotovskii, M.T.; Mogilevskaya, M.P.; Obol'nikova, E.A.; Kogan, L.M.; Samokhvalov, G.I.

    1986-01-01

    A method has been developed for the qualitative and quantitative determination of ubiquinones CoQ 6 -CoQ 10 , using high-efficiency reversed-phase liquid chromatography. Tocopherol acetate was used as the internal standard

  14. Quantitative rotating frame relaxometry methods in MRI.

    Science.gov (United States)

    Gilani, Irtiza Ali; Sepponen, Raimo

    2016-06-01

    Macromolecular degeneration and biochemical changes in tissue can be quantified using rotating frame relaxometry in MRI. It has been shown in several studies that the rotating frame longitudinal relaxation rate constant (R1ρ ) and the rotating frame transverse relaxation rate constant (R2ρ ) are sensitive biomarkers of phenomena at the cellular level. In this comprehensive review, existing MRI methods for probing the biophysical mechanisms that affect the rotating frame relaxation rates of the tissue (i.e. R1ρ and R2ρ ) are presented. Long acquisition times and high radiofrequency (RF) energy deposition into tissue during the process of spin-locking in rotating frame relaxometry are the major barriers to the establishment of these relaxation contrasts at high magnetic fields. Therefore, clinical applications of R1ρ and R2ρ MRI using on- or off-resonance RF excitation methods remain challenging. Accordingly, this review describes the theoretical and experimental approaches to the design of hard RF pulse cluster- and adiabatic RF pulse-based excitation schemes for accurate and precise measurements of R1ρ and R2ρ . The merits and drawbacks of different MRI acquisition strategies for quantitative relaxation rate measurement in the rotating frame regime are reviewed. In addition, this review summarizes current clinical applications of rotating frame MRI sequences. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Quantitative determination of residual 1,4-dioxane in three-dimensional printed bone scaffold

    Directory of Open Access Journals (Sweden)

    Ling Li

    2018-04-01

    Full Text Available Summary: Background/Objective: A novel porous scaffold poly (lactide-co-glycolide and tricalcium phosphate (PLGA/TCP was developed by three-dimensional printing technology for bone defect repair. As a Class 2 solvent with less severe toxicity, content of residual 1,4-dioxane in this newly developed scaffold should be rigorously controlled when it is translated to clinical use. In this study, a headspace gas chromatography-mass spectrometric (HS-GC-MS method and related testing protocol were developed for quantitative determination of 1,4-dioxane in the PLGA/TCP composite scaffolds. Methods: Matrix effect analysis was used to optimise the pretreatment method of the scaffolds. Then, the procedure for testing 1,4-dioxane using HS-GC-MS was set up. The accuracy, precision, and robustness of this newly developed quantitative method were also validated before quantification of 1,4-dioxane in the scaffolds with different drying procedures. Results: Dimethyl formamide (DMF was the optimal solvent for dissolving scaffolds for GC-MS with proper sensitivity and without matrix effect. Then, the optimised procedure was determined as: the scaffolds were dissolved in DMF and kept at 90°C for 40 minutes, separated on a HP-5MS column, and detected by mass spectroscopy. Recovery experiments gave 97.9–100.7% recovery for 1,4-dioxane. The linear range for 1,4-dioxane was determined as 1–40 ppm with linear correlation coefficient ≥ 0.9999. Intraday and interday precision was determined as being within relative standard deviation of below 0.68%. The passable drying procedure was related to lyophilising (−50°C, 50 Pa the scaffolds for 2 days and drying in vacuum (50 Pa for 7 days. Conclusion: This is the first quantitative method established to test 1,4-dixoane in a novel scaffold. This method was validated with good accuracy and reproducibility, and met the methodological requirements of the Guideline 9101 documented in the Chinese Pharmacopoeia 2015

  16. Assessment of acute myocarditis by cardiac magnetic resonance imaging: Comparison of qualitative and quantitative analysis methods.

    Science.gov (United States)

    Imbriaco, Massimo; Nappi, Carmela; Puglia, Marta; De Giorgi, Marco; Dell'Aversana, Serena; Cuocolo, Renato; Ponsiglione, Andrea; De Giorgi, Igino; Polito, Maria Vincenza; Klain, Michele; Piscione, Federico; Pace, Leonardo; Cuocolo, Alberto

    2017-10-26

    To compare cardiac magnetic resonance (CMR) qualitative and quantitative analysis methods for the noninvasive assessment of myocardial inflammation in patients with suspected acute myocarditis (AM). A total of 61 patients with suspected AM underwent coronary angiography and CMR. Qualitative analysis was performed applying Lake-Louise Criteria (LLC), followed by quantitative analysis based on the evaluation of edema ratio (ER) and global relative enhancement (RE). Diagnostic performance was assessed for each method by measuring the area under the curves (AUC) of the receiver operating characteristic analyses. The final diagnosis of AM was based on symptoms and signs suggestive of cardiac disease, evidence of myocardial injury as defined by electrocardiogram changes, elevated troponin I, exclusion of coronary artery disease by coronary angiography, and clinical and echocardiographic follow-up at 3 months after admission to the chest pain unit. In all patients, coronary angiography did not show significant coronary artery stenosis. Troponin I levels and creatine kinase were higher in patients with AM compared to those without (both P quantitative (ER 0.89 and global RE 0.80) analyses were also similar. Qualitative and quantitative CMR analysis methods show similar diagnostic accuracy for the diagnosis of AM. These findings suggest that a simplified approach using a shortened CMR protocol including only T2-weighted STIR sequences might be useful to rule out AM in patients with acute coronary syndrome and normal coronary angiography.

  17. Domestication of smartphones and mobile applications: A quantitative mixed-method study

    OpenAIRE

    de Reuver, G.A.; Nikou, S; Bouwman, W.A.G.A.

    2016-01-01

    Smartphones are finding their way into our daily lives. This paper examines the domestication of smartphones by looking at how the way we use mobile applications affects our everyday routines. Data is collected through an innovative quantitative mixed-method approach, combining log data from smartphones and survey (perception) data. We find that there are dimensions of domestication that explain how the use of smartphones affects our daily routines. Contributions are stronger for downloaded a...

  18. The effect of temperature on the mechanical aspects of rigor mortis in a liquid paraffin model.

    Science.gov (United States)

    Ozawa, Masayoshi; Iwadate, Kimiharu; Matsumoto, Sari; Asakura, Kumiko; Ochiai, Eriko; Maebashi, Kyoko

    2013-11-01

    Rigor mortis is an important phenomenon to estimate the postmortem interval in forensic medicine. Rigor mortis is affected by temperature. We measured stiffness of rat muscles using a liquid paraffin model to monitor the mechanical aspects of rigor mortis at five temperatures (37, 25, 10, 5 and 0°C). At 37, 25 and 10°C, the progression of stiffness was slower in cooler conditions. At 5 and 0°C, the muscle stiffness increased immediately after the muscles were soaked in cooled liquid paraffin and then muscles gradually became rigid without going through a relaxed state. This phenomenon suggests that it is important to be careful when estimating the postmortem interval in cold seasons. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  19. Qualitative to quantitative: linked trajectory of method triangulation in a study on HIV/AIDS in Goa, India.

    Science.gov (United States)

    Bailey, Ajay; Hutter, Inge

    2008-10-01

    With 3.1 million people estimated to be living with HIV/AIDS in India and 39.5 million people globally, the epidemic has posed academics the challenge of identifying behaviours and their underlying beliefs in the effort to reduce the risk of HIV transmission. The Health Belief Model (HBM) is frequently used to identify risk behaviours and adherence behaviour in the field of HIV/AIDS. Risk behaviour studies that apply HBM have been largely quantitative and use of qualitative methodology is rare. The marriage of qualitative and quantitative methods has never been easy. The challenge is in triangulating the methods. Method triangulation has been largely used to combine insights from the qualitative and quantitative methods but not to link both the methods. In this paper we suggest a linked trajectory of method triangulation (LTMT). The linked trajectory aims to first gather individual level information through in-depth interviews and then to present the information as vignettes in focus group discussions. We thus validate information obtained from in-depth interviews and gather emic concepts that arise from the interaction. We thus capture both the interpretation and the interaction angles of the qualitative method. Further, using the qualitative information gained, a survey is designed. In doing so, the survey questions are grounded and contextualized. We employed this linked trajectory of method triangulation in a study on the risk assessment of HIV/AIDS among migrant and mobile men. Fieldwork was carried out in Goa, India. Data come from two waves of studies, first an explorative qualitative study (2003), second a larger study (2004-2005), including in-depth interviews (25), focus group discussions (21) and a survey (n=1259). By employing the qualitative to quantitative LTMT we can not only contextualize the existing concepts of the HBM, but also validate new concepts and identify new risk groups.

  20. The rigorous stochastic matrix multiplication scheme for the calculations of reduced equilibrium density matrices of open multilevel quantum systems

    International Nuclear Information System (INIS)

    Chen, Xin

    2014-01-01

    Understanding the roles of the temporary and spatial structures of quantum functional noise in open multilevel quantum molecular systems attracts a lot of theoretical interests. I want to establish a rigorous and general framework for functional quantum noises from the constructive and computational perspectives, i.e., how to generate the random trajectories to reproduce the kernel and path ordering of the influence functional with effective Monte Carlo methods for arbitrary spectral densities. This construction approach aims to unify the existing stochastic models to rigorously describe the temporary and spatial structure of Gaussian quantum noises. In this paper, I review the Euclidean imaginary time influence functional and propose the stochastic matrix multiplication scheme to calculate reduced equilibrium density matrices (REDM). In addition, I review and discuss the Feynman-Vernon influence functional according to the Gaussian quadratic integral, particularly its imaginary part which is critical to the rigorous description of the quantum detailed balance. As a result, I establish the conditions under which the influence functional can be interpreted as the average of exponential functional operator over real-valued Gaussian processes for open multilevel quantum systems. I also show the difference between the local and nonlocal phonons within this framework. With the stochastic matrix multiplication scheme, I compare the normalized REDM with the Boltzmann equilibrium distribution for open multilevel quantum systems

  1. A rigorous treatment of uncertainty quantification for Silicon damage metrics

    International Nuclear Information System (INIS)

    Griffin, P.

    2016-01-01

    These report summaries the contributions made by Sandia National Laboratories in support of the International Atomic Energy Agency (IAEA) Nuclear Data Section (NDS) Technical Meeting (TM) on Nuclear Reaction Data and Uncertainties for Radiation Damage. This work focused on a rigorous treatment of the uncertainties affecting the characterization of the displacement damage seen in silicon semiconductors. (author)

  2. Paper 3: Content and Rigor of Algebra Credit Recovery Courses

    Science.gov (United States)

    Walters, Kirk; Stachel, Suzanne

    2014-01-01

    This paper describes the content, organization and rigor of the f2f and online summer algebra courses that were delivered in summers 2011 and 2012. Examining the content of both types of courses is important because research suggests that algebra courses with certain features may be better than others in promoting success for struggling students.…

  3. Cross-method validation as a solution to the problem of excessive simplification of measurement in quantitative IR research

    DEFF Research Database (Denmark)

    Beach, Derek

    2007-01-01

    The purpose of this article is to make IR scholars more aware of the costs of choosing quantitative methods. The article first shows that quantification can have analytical ‘costs’ when the measures created are too simple to capture the essence of the systematized concept that was supposed...... detail based upon a review of the democratic peace literature. I then offer two positive suggestions for a way forward. First, I argue that quantitative scholars should spend more time validating their measures, and in particular should engage in multi-method partnerships with qualitative scholars...... that have a deep understanding of particular cases in order to exploit the comparative advantages of qualitative methodology, using the more accurate qualitative measures to validate their own quantitative measures. Secondly, quantitative scholars should lower their level of ambition given the often poor...

  4. A novel dual energy method for enhanced quantitative computed tomography

    Science.gov (United States)

    Emami, A.; Ghadiri, H.; Rahmim, A.; Ay, M. R.

    2018-01-01

    Accurate assessment of bone mineral density (BMD) is critically important in clinical practice, and conveniently enabled via quantitative computed tomography (QCT). Meanwhile, dual-energy QCT (DEQCT) enables enhanced detection of small changes in BMD relative to single-energy QCT (SEQCT). In the present study, we aimed to investigate the accuracy of QCT methods, with particular emphasis on a new dual-energy approach, in comparison to single-energy and conventional dual-energy techniques. We used a sinogram-based analytical CT simulator to model the complete chain of CT data acquisitions, and assessed performance of SEQCT and different DEQCT techniques in quantification of BMD. We demonstrate a 120% reduction in error when using a proposed dual-energy Simultaneous Equation by Constrained Least-squares method, enabling more accurate bone mineral measurements.

  5. A New Green Method for the Quantitative Analysis of Enrofloxacin by Fourier-Transform Infrared Spectroscopy.

    Science.gov (United States)

    Rebouças, Camila Tavares; Kogawa, Ana Carolina; Salgado, Hérida Regina Nunes

    2018-05-18

    Background: A green analytical chemistry method was developed for quantification of enrofloxacin in tablets. The drug, a second-generation fluoroquinolone, was first introduced in veterinary medicine for the treatment of various bacterial species. Objective: This study proposed to develop, validate, and apply a reliable, low-cost, fast, and simple IR spectroscopy method for quantitative routine determination of enrofloxacin in tablets. Methods: The method was completely validated according to the International Conference on Harmonisation guidelines, showing accuracy, precision, selectivity, robustness, and linearity. Results: It was linear over the concentration range of 1.0-3.0 mg with correlation coefficients >0.9999 and LOD and LOQ of 0.12 and 0.36 mg, respectively. Conclusions: Now that this IR method has met performance qualifications, it can be adopted and applied for the analysis of enrofloxacin tablets for production process control. The validated method can also be utilized to quantify enrofloxacin in tablets and thus is an environmentally friendly alternative for the routine analysis of enrofloxacin in quality control. Highlights: A new green method for the quantitative analysis of enrofloxacin by Fourier-Transform Infrared spectroscopy was validated. It is a fast, clean and low-cost alternative for the evaluation of enrofloxacin tablets.

  6. Dosimetric effects of edema in permanent prostate seed implants: a rigorous solution

    International Nuclear Information System (INIS)

    Chen Zhe; Yue Ning; Wang Xiaohong; Roberts, Kenneth B.; Peschel, Richard; Nath, Ravinder

    2000-01-01

    Purpose: To derive a rigorous analytic solution to the dosimetric effects of prostate edema so that its impact on the conventional pre-implant and post-implant dosimetry can be studied for any given radioactive isotope and edema characteristics. Methods and Materials: The edema characteristics observed by Waterman et al (Int. J. Rad. Onc. Biol. Phys, 41:1069-1077; 1998) was used to model the time evolution of the prostate and the seed locations. The total dose to any part of prostate tissue from a seed implant was calculated analytically by parameterizing the dose fall-off from a radioactive seed as a single inverse power function of distance, with proper account of the edema-induced time evolution. The dosimetric impact of prostate edema was determined by comparing the dose calculated with full consideration of prostate edema to that calculated with the conventional dosimetry approach where the seed locations and the target volume are assumed to be stationary. Results: A rigorous analytic solution on the relative dosimetric effects of prostate edema was obtained. This solution proved explicitly that the relative dosimetric effects of edema, as found in the previous numerical studies by Yue et. al. (Int. J. Radiat. Oncol. Biol. Phys. 43, 447-454, 1999), are independent of the size and the shape of the implant target volume and are independent of the number and the locations of the seeds implanted. It also showed that the magnitude of relative dosimetric effects is independent of the location of dose evaluation point within the edematous target volume. It implies that the relative dosimetric effects of prostate edema are universal with respect to a given isotope and edema characteristic. A set of master tables for the relative dosimetric effects of edema were obtained for a wide range of edema characteristics for both 125 I and 103 Pd prostate seed implants. Conclusions: A rigorous analytic solution of the relative dosimetric effects of prostate edema has been

  7. New chromatographic method for separating Omeprazole from its degradation components and the quantitatively determining it in its pharmaceutical products

    International Nuclear Information System (INIS)

    Touma, M.; Rajab, A.; Seuleiman, M.

    2007-01-01

    New chromatographic method for Quantitative Determination of Omeprazole in its Pharmaceutical Products was produced. Omeprazole and its degradation components were well separated in same chromatogram by using high perfume liquid chromatography (HPLC). The new analytical method has been validated by these characteristic tests (accuracy, precision, range, linearity, specificity/selectivity, limit of detection (LOD) and limit of quantitative (LOQ) ).(author)

  8. New chromatographic Methods for Separation of Lansoprazole from its Degradation Components and The Quantitative Determination in its Pharmaceutical Products

    International Nuclear Information System (INIS)

    Touma, M.; Rajab, A.

    2009-01-01

    New chromatographic method was found for Quantitative Determination of Lansoprazole in its pharmaceutical products. Lansoprazole and its degradation components were well separated in same chromatogram by using high perfume liquid chromatography (HPLC). The new analytical method has been validated by these characteristic tests (accuracy, precision, range, linearity, specificity/selectivity, limit of detection (LOD) and limit of quantitative (LOQ)). (author)

  9. Quantitative phase analysis of uranium carbide from x-ray diffraction data using the Rietveld method

    International Nuclear Information System (INIS)

    Singh Mudher, K.D.; Krishnan, K.

    2003-01-01

    Quantitative phase analysis of a uranium carbide sample was carried out from the x-ray diffraction data by Rietveld profile fitting method. The method does not require the addition of any reference material. The percentage of UC, UC 2 and UO 2 phases in the sample were determined. (author)

  10. A scanning electron microscope method for automated, quantitative analysis of mineral matter in coal

    Energy Technology Data Exchange (ETDEWEB)

    Creelman, R.A.; Ward, C.R. [R.A. Creelman and Associates, Epping, NSW (Australia)

    1996-07-01

    Quantitative mineralogical analysis has been carried out in a series of nine coal samples from Australia, South Africa and China using a newly-developed automated image analysis system coupled to a scanning electron microscopy. The image analysis system (QEM{asterisk}SEM) gathers X-ray spectra and backscattered electron data from a number of points on a conventional grain-mount polished section under the SEM, and interprets the data from each point in mineralogical terms. The cumulative data in each case was integrated to provide a volumetric modal analysis of the species present in the coal samples, expressed as percentages of the respective coals` mineral matter. Comparison was made of the QEM{asterisk}SEM results to data obtained from the same samples using other methods of quantitative mineralogical analysis, namely X-ray diffraction of the low-temperature oxygen-plasma ash and normative calculation from the (high-temperature) ash analysis and carbonate CO{sub 2} data. Good agreement was obtained from all three methods for quartz in the coals, and also for most of the iron-bearing minerals. The correlation between results from the different methods was less strong, however, for individual clay minerals, or for minerals such as calcite, dolomite and phosphate species that made up only relatively small proportions of the mineral matter. The image analysis approach, using the electron microscope for mineralogical studies, has significant potential as a supplement to optical microscopy in quantitative coal characterisation. 36 refs., 3 figs., 4 tabs.

  11. Mixed Methods in Biomedical and Health Services Research

    Science.gov (United States)

    Curry, Leslie A.; Krumholz, Harlan M.; O’Cathain, Alicia; Plano Clark, Vicki L.; Cherlin, Emily; Bradley, Elizabeth H.

    2013-01-01

    Mixed methods studies, in which qualitative and quantitative methods are combined in a single program of inquiry, can be valuable in biomedical and health services research, where the complementary strengths of each approach can yield greater insight into complex phenomena than either approach alone. Although interest in mixed methods is growing among science funders and investigators, written guidance on how to conduct and assess rigorous mixed methods studies is not readily accessible to the general readership of peer-reviewed biomedical and health services journals. Furthermore, existing guidelines for publishing mixed methods studies are not well known or applied by researchers and journal editors. Accordingly, this paper is intended to serve as a concise, practical resource for readers interested in core principles and practices of mixed methods research. We briefly describe mixed methods approaches and present illustrations from published biomedical and health services literature, including in cardiovascular care, summarize standards for the design and reporting of these studies, and highlight four central considerations for investigators interested in using these methods. PMID:23322807

  12. Quantitative analysis of dynamic adhesion properties in human hepatocellular carcinoma cells with fullerenol.

    Science.gov (United States)

    Liu, Yang; Wang, Zuobin; Wang, Xinyue; Huang, Yanhong

    2015-12-01

    In this study, the effect of fullerenol (C60(OH)24) on the cellular dynamic biomechanical behaviors of living human hepatocellular carcinoma (SMCC-7721) cancer cells were investigated by atomic force microscope (AFM) nanoindentation. As an important biomarker of cellular information, the cell adhesion is essential to maintain proper functioning as well as links with the pathogenesis and canceration. Nonetheless, it is challenging to properly evaluate the complex adhesion properties as all the biomechanical parameters interfere with each other. To investigate the dynamic adhesion changes, especially in the case of the fullerenol treatment, the detachment force and work, adhesion events, and membrane tether properties were measured and analyzed systematically with the proposed quantitative method. The statistical analyses suggest that, under the same operating parameters of AFM, the dependence of adhesion energy on the tip-cell contact area is weakened after the fullerenol treatment and the probability of adhesion decreases significantly from 30.6% to 4.2%. In addition, the disruption of the cytoskeleton resulted in a 34% decrease of the average membrane tether force and a 21% increase of the average tether length. Benefiting from the quantitative method, this work contributes to revealing the effects of fullerenol on the cellular biomechanical properties of the living SMCC-7721 cells in a precise and rigorous way and additionally is further instructive to interpret the interaction mechanism of other potential nanomedicines with living cells. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Quantitative firing transformations of a triaxial ceramic by X-ray diffraction methods

    International Nuclear Information System (INIS)

    Conconi, M.S.; Gauna, M.R.; Serra, M.F.; Suarez, G.; Aglietti, E.F.; Rendtorff, N.M.

    2014-01-01

    The firing transformations of traditional (clay based) ceramics are of technological and archaeological interest, and are usually reported qualitatively or semi quantitatively. These kinds of systems present an important complexity, especially for X-ray diffraction techniques, due to the presence of fully crystalline, low crystalline and amorphous phases. In this article we present the results of a qualitative and quantitative X-ray diffraction Rietveld analysis of the fully crystalline (kaolinite, quartz, cristobalite, feldspars and/or mullite), the low crystalline (metakaolinite and/or spinel type pre-mullite) and glassy phases evolution of a triaxial (clay-quartz-feldspar) ceramic fired in a wide temperature range between 900 and 1300 deg C. The employed methodology to determine low crystalline and glassy phase abundances is based in a combination of the internal standard method and the use of a nanocrystalline model where the long-range order is lost, respectively. A preliminary sintering characterization was carried out by contraction, density and porosity evolution with the firing temperature. Simultaneous thermo-gravimetric and differential thermal analysis was carried out to elucidate the actual temperature at which the chemical changes occur. Finally, the quantitative analysis based on the Rietveld refinement of the X-ray diffraction patterns was performed. The kaolinite decomposition into metakaolinite was determined quantitatively; the intermediate (980 deg C) spinel type alumino-silicate formation was also quantified; the incongruent fusion of the potash feldspar was observed and quantified together with the final mullitization and the amorphous (glassy) phase formation.The methodology used to analyze the X-ray diffraction patterns proved to be suitable to evaluate quantitatively the thermal transformations that occur in a complex system like the triaxial ceramics. The evaluated phases can be easily correlated with the processing variables and materials

  14. Quantitative firing transformations of a triaxial ceramic by X-ray diffraction methods

    Energy Technology Data Exchange (ETDEWEB)

    Conconi, M.S.; Gauna, M.R.; Serra, M.F. [Centro de Tecnologia de Recursos Minerales y Ceramica (CETMIC), Buenos Aires (Argentina); Suarez, G.; Aglietti, E.F.; Rendtorff, N.M., E-mail: rendtorff@cetmic.unlp.edu.ar [Universidad Nacional de La Plata (UNLP), Buenos Aires (Argentina). Fac. de Ciencias Exactas. Dept. de Quimica

    2014-10-15

    The firing transformations of traditional (clay based) ceramics are of technological and archaeological interest, and are usually reported qualitatively or semi quantitatively. These kinds of systems present an important complexity, especially for X-ray diffraction techniques, due to the presence of fully crystalline, low crystalline and amorphous phases. In this article we present the results of a qualitative and quantitative X-ray diffraction Rietveld analysis of the fully crystalline (kaolinite, quartz, cristobalite, feldspars and/or mullite), the low crystalline (metakaolinite and/or spinel type pre-mullite) and glassy phases evolution of a triaxial (clay-quartz-feldspar) ceramic fired in a wide temperature range between 900 and 1300 deg C. The employed methodology to determine low crystalline and glassy phase abundances is based in a combination of the internal standard method and the use of a nanocrystalline model where the long-range order is lost, respectively. A preliminary sintering characterization was carried out by contraction, density and porosity evolution with the firing temperature. Simultaneous thermo-gravimetric and differential thermal analysis was carried out to elucidate the actual temperature at which the chemical changes occur. Finally, the quantitative analysis based on the Rietveld refinement of the X-ray diffraction patterns was performed. The kaolinite decomposition into metakaolinite was determined quantitatively; the intermediate (980 deg C) spinel type alumino-silicate formation was also quantified; the incongruent fusion of the potash feldspar was observed and quantified together with the final mullitization and the amorphous (glassy) phase formation.The methodology used to analyze the X-ray diffraction patterns proved to be suitable to evaluate quantitatively the thermal transformations that occur in a complex system like the triaxial ceramics. The evaluated phases can be easily correlated with the processing variables and materials

  15. Acceptability criteria for linear dependence in validating UV-spectrophotometric methods of quantitative determination in forensic and toxicological analysis

    Directory of Open Access Journals (Sweden)

    L. Yu. Klimenko

    2014-08-01

    Full Text Available Introduction. This article is the result of authors’ research in the field of development of the approaches to validation of quantitative determination methods for purposes of forensic and toxicological analysis and devoted to the problem of acceptability criteria formation for validation parameter «linearity/calibration model». The aim of research. The purpose of this paper is to analyse the present approaches to acceptability estimation of the calibration model chosen for method description according to the requirements of the international guidances, to form the own approaches to acceptability estimation of the linear dependence when carrying out the validation of UV-spectrophotometric methods of quantitative determination for forensic and toxicological analysis. Materials and methods. UV-spectrophotometric method of doxylamine quantitative determination in blood. Results. The approaches to acceptability estimation of calibration models when carrying out the validation of bioanalytical methods is stated in international papers, namely «Guidance for Industry: Bioanalytical method validation» (U.S. FDA, 2001, «Standard Practices for Method Validation in Forensic Toxicology» (SWGTOX, 2012, «Guidance for the Validation of Analytical Methodology and Calibration of Equipment used for Testing of Illicit Drugs in Seized Materials and Biological Specimens» (UNODC, 2009 and «Guideline on validation of bioanalytical methods» (ЕМА, 2011 have been analysed. It has been suggested to be guided by domestic developments in the field of validation of analysis methods for medicines and, particularly, by the approaches to validation methods in the variant of the calibration curve method for forming the acceptability criteria of the obtained linear dependences when carrying out the validation of UV-spectrophotometric methods of quantitative determination for forensic and toxicological analysis. The choice of the method of calibration curve is

  16. A Draft Conceptual Framework of Relevant Theories to Inform Future Rigorous Research on Student Service-Learning Outcomes

    Science.gov (United States)

    Whitley, Meredith A.

    2014-01-01

    While the quality and quantity of research on service-learning has increased considerably over the past 20 years, researchers as well as governmental and funding agencies have called for more rigor in service-learning research. One key variable in improving rigor is using relevant existing theories to improve the research. The purpose of this…

  17. Quantitative Analysis of Venus Radar Backscatter Data in ArcGIS

    Science.gov (United States)

    Long, S. M.; Grosfils, E. B.

    2005-01-01

    Ongoing mapping of the Ganiki Planitia (V14) quadrangle of Venus and definition of material units has involved an integrated but qualitative analysis of Magellan radar backscatter images and topography using standard geomorphological mapping techniques. However, such analyses do not take full advantage of the quantitative information contained within the images. Analysis of the backscatter coefficient allows a much more rigorous statistical comparison between mapped units, permitting first order selfsimilarity tests of geographically separated materials assigned identical geomorphological labels. Such analyses cannot be performed directly on pixel (DN) values from Magellan backscatter images, because the pixels are scaled to the Muhleman law for radar echoes on Venus and are not corrected for latitudinal variations in incidence angle. Therefore, DN values must be converted based on pixel latitude back to their backscatter coefficient values before accurate statistical analysis can occur. Here we present a method for performing the conversions and analysis of Magellan backscatter data using commonly available ArcGIS software and illustrate the advantages of the process for geological mapping.

  18. Quantitative analysis of drug distribution by ambient mass spectrometry imaging method with signal extinction normalization strategy and inkjet-printing technology.

    Science.gov (United States)

    Luo, Zhigang; He, Jingjing; He, Jiuming; Huang, Lan; Song, Xiaowei; Li, Xin; Abliz, Zeper

    2018-03-01

    Quantitative mass spectrometry imaging (MSI) is a robust approach that provides both quantitative and spatial information for drug candidates' research. However, because of complicated signal suppression and interference, acquiring accurate quantitative information from MSI data remains a challenge, especially for whole-body tissue sample. Ambient MSI techniques using spray-based ionization appear to be ideal for pharmaceutical quantitative MSI analysis. However, it is more challenging, as it involves almost no sample preparation and is more susceptible to ion suppression/enhancement. Herein, based on our developed air flow-assisted desorption electrospray ionization (AFADESI)-MSI technology, an ambient quantitative MSI method was introduced by integrating inkjet-printing technology with normalization of the signal extinction coefficient (SEC) using the target compound itself. The method utilized a single calibration curve to quantify multiple tissue types. Basic blue 7 and an antitumor drug candidate (S-(+)-deoxytylophorinidine, CAT) were chosen to initially validate the feasibility and reliability of the quantitative MSI method. Rat tissue sections (heart, kidney, and brain) administered with CAT was then analyzed. The quantitative MSI analysis results were cross-validated by LC-MS/MS analysis data of the same tissues. The consistency suggests that the approach is able to fast obtain the quantitative MSI data without introducing interference into the in-situ environment of the tissue sample, and is potential to provide a high-throughput, economical and reliable approach for drug discovery and development. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Applying rigorous decision analysis methodology to optimization of a tertiary recovery project

    International Nuclear Information System (INIS)

    Wackowski, R.K.; Stevens, C.E.; Masoner, L.O.; Attanucci, V.; Larson, J.L.; Aslesen, K.S.

    1992-01-01

    This paper reports that the intent of this study was to rigorously look at all of the possible expansion, investment, operational, and CO 2 purchase/recompression scenarios (over 2500) to yield a strategy that would maximize net present value of the CO 2 project at the Rangely Weber Sand Unit. Traditional methods of project management, which involve analyzing large numbers of single case economic evaluations, was found to be too cumbersome and inaccurate for an analysis of this scope. The decision analysis methodology utilized a statistical approach which resulted in a range of economic outcomes. Advantages of the decision analysis methodology included: a more organized approach to classification of decisions and uncertainties; a clear sensitivity method to identify the key uncertainties; an application of probabilistic analysis through the decision tree; and a comprehensive display of the range of possible outcomes for communication to decision makers. This range made it possible to consider the upside and downside potential of the options and to weight these against the Unit's strategies. Savings in time and manpower required to complete the study were also realized

  20. Sample preparation methods for quantitative detection of DNA by molecular assays and marine biosensors

    International Nuclear Information System (INIS)

    Cox, Annie M.; Goodwin, Kelly D.

    2013-01-01

    Highlights: • DNA extraction methods affected measured qPCR target recovery. • Recovery and variability differed, sometimes by more than an order of magnitude. • SCODA did not offer significant improvement with PCR-inhibited seawater. • Aggressive lysis did appear to improve target recovery. • Reliable and affordable correction methods are needed for quantitative PCR. -- Abstract: The need for quantitative molecular methods is growing in environmental, food, and medical fields but is hindered by low and variable DNA extraction and by co-extraction of PCR inhibitors. DNA extracts from Enterococcus faecium, seawater, and seawater spiked with E. faecium and Vibrio parahaemolyticus were tested by qPCR for target recovery and inhibition. Conventional and novel methods were tested, including Synchronous Coefficient of Drag Alteration (SCODA) and lysis and purification systems used on an automated genetic sensor (the Environmental Sample Processor, ESP). Variable qPCR target recovery and inhibition were measured, significantly affecting target quantification. An aggressive lysis method that utilized chemical, enzymatic, and mechanical disruption enhanced target recovery compared to commercial kit protocols. SCODA purification did not show marked improvement over commercial spin columns. Overall, data suggested a general need to improve sample preparation and to accurately assess and account for DNA recovery and inhibition in qPCR applications

  1. Building an Evidence Base to Inform Interventions for Pregnant and Parenting Adolescents: A Call for Rigorous Evaluation

    Science.gov (United States)

    Burrus, Barri B.; Scott, Alicia Richmond

    2012-01-01

    Adolescent parents and their children are at increased risk for adverse short- and long-term health and social outcomes. Effective interventions are needed to support these young families. We studied the evidence base and found a dearth of rigorously evaluated programs. Strategies from successful interventions are needed to inform both intervention design and policies affecting these adolescents. The lack of rigorous evaluations may be attributable to inadequate emphasis on and sufficient funding for evaluation, as well as to challenges encountered by program evaluators working with this population. More rigorous program evaluations are urgently needed to provide scientifically sound guidance for programming and policy decisions. Evaluation lessons learned have implications for other vulnerable populations. PMID:22897541

  2. PRO development: rigorous qualitative research as the crucial foundation

    OpenAIRE

    Lasch, Kathryn Eilene; Marquis, Patrick; Vigneux, Marc; Abetz, Linda; Arnould, Benoit; Bayliss, Martha; Crawford, Bruce; Rosa, Kathleen

    2010-01-01

    Recently published articles have described criteria to assess qualitative research in the health field in general, but very few articles have delineated qualitative methods to be used in the development of Patient-Reported Outcomes (PROs). In fact, how PROs are developed with subject input through focus groups and interviews has been given relatively short shrift in the PRO literature when compared to the plethora of quantitative articles on the psychometric properties of PROs. If documented ...

  3. A method for normalizing pathology images to improve feature extraction for quantitative pathology

    International Nuclear Information System (INIS)

    Tam, Allison; Barker, Jocelyn; Rubin, Daniel

    2016-01-01

    Purpose: With the advent of digital slide scanning technologies and the potential proliferation of large repositories of digital pathology images, many research studies can leverage these data for biomedical discovery and to develop clinical applications. However, quantitative analysis of digital pathology images is impeded by batch effects generated by varied staining protocols and staining conditions of pathological slides. Methods: To overcome this problem, this paper proposes a novel, fully automated stain normalization method to reduce batch effects and thus aid research in digital pathology applications. Their method, intensity centering and histogram equalization (ICHE), normalizes a diverse set of pathology images by first scaling the centroids of the intensity histograms to a common point and then applying a modified version of contrast-limited adaptive histogram equalization. Normalization was performed on two datasets of digitized hematoxylin and eosin (H&E) slides of different tissue slices from the same lung tumor, and one immunohistochemistry dataset of digitized slides created by restaining one of the H&E datasets. Results: The ICHE method was evaluated based on image intensity values, quantitative features, and the effect on downstream applications, such as a computer aided diagnosis. For comparison, three methods from the literature were reimplemented and evaluated using the same criteria. The authors found that ICHE not only improved performance compared with un-normalized images, but in most cases showed improvement compared with previous methods for correcting batch effects in the literature. Conclusions: ICHE may be a useful preprocessing step a digital pathology image processing pipeline

  4. A method for normalizing pathology images to improve feature extraction for quantitative pathology

    Energy Technology Data Exchange (ETDEWEB)

    Tam, Allison [Stanford Institutes of Medical Research Program, Stanford University School of Medicine, Stanford, California 94305 (United States); Barker, Jocelyn [Department of Radiology, Stanford University School of Medicine, Stanford, California 94305 (United States); Rubin, Daniel [Department of Radiology, Stanford University School of Medicine, Stanford, California 94305 and Department of Medicine (Biomedical Informatics Research), Stanford University School of Medicine, Stanford, California 94305 (United States)

    2016-01-15

    Purpose: With the advent of digital slide scanning technologies and the potential proliferation of large repositories of digital pathology images, many research studies can leverage these data for biomedical discovery and to develop clinical applications. However, quantitative analysis of digital pathology images is impeded by batch effects generated by varied staining protocols and staining conditions of pathological slides. Methods: To overcome this problem, this paper proposes a novel, fully automated stain normalization method to reduce batch effects and thus aid research in digital pathology applications. Their method, intensity centering and histogram equalization (ICHE), normalizes a diverse set of pathology images by first scaling the centroids of the intensity histograms to a common point and then applying a modified version of contrast-limited adaptive histogram equalization. Normalization was performed on two datasets of digitized hematoxylin and eosin (H&E) slides of different tissue slices from the same lung tumor, and one immunohistochemistry dataset of digitized slides created by restaining one of the H&E datasets. Results: The ICHE method was evaluated based on image intensity values, quantitative features, and the effect on downstream applications, such as a computer aided diagnosis. For comparison, three methods from the literature were reimplemented and evaluated using the same criteria. The authors found that ICHE not only improved performance compared with un-normalized images, but in most cases showed improvement compared with previous methods for correcting batch effects in the literature. Conclusions: ICHE may be a useful preprocessing step a digital pathology image processing pipeline.

  5. Two quantitative forecasting methods for macroeconomic indicators in Czech Republic

    Directory of Open Access Journals (Sweden)

    Mihaela BRATU (SIMIONESCU

    2012-03-01

    Full Text Available Econometric modelling and exponential smoothing techniques are two quantitative forecasting methods with good results in practice, but the objective of the research was to find out which of the two techniques are better for short run predictions. Therefore, for inflation, unemployment and interest rate in Czech Republic some accuracy indicators were calculated for the predictions based on these methods. Short run forecasts on a horizon of 3 months were made for December 2011-February 2012, the econometric models being updated. For Czech Republic, the exponential smoothing techniques provided more accurate forecasts than the econometric models (VAR(2 models, ARMA procedure and models with lagged variables. One explication for the better performance of smoothing techniques would be that in the chosen countries the short run predictions more influenced by the recent evolution of the indicators.

  6. Rapid method for protein quantitation by Bradford assay after elimination of the interference of polysorbate 80.

    Science.gov (United States)

    Cheng, Yongfeng; Wei, Haiming; Sun, Rui; Tian, Zhigang; Zheng, Xiaodong

    2016-02-01

    Bradford assay is one of the most common methods for measuring protein concentrations. However, some pharmaceutical excipients, such as detergents, interfere with Bradford assay even at low concentrations. Protein precipitation can be used to overcome sample incompatibility with protein quantitation. But the rate of protein recovery caused by acetone precipitation is only about 70%. In this study, we found that sucrose not only could increase the rate of protein recovery after 1 h acetone precipitation, but also did not interfere with Bradford assay. So we developed a method for rapid protein quantitation in protein drugs even if they contained interfering substances. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Study on a quantitative evaluation method of equipment maintenance level and plant safety level for giant complex plant system

    International Nuclear Information System (INIS)

    Aoki, Takayuki

    2010-01-01

    In this study, a quantitative method on maintenance level which is determined by the two factors, maintenance plan and field work implementation ability by maintenance crew is discussed. And also a quantitative evaluation method on safety level for giant complex plant system is discussed. As a result of consideration, the following results were obtained. (1) It was considered that equipment condition after maintenance work was determined by the two factors, maintenance plan and field work implementation ability possessed by maintenance crew. The equipment condition determined by the two factors was named as 'equipment maintenance level' and its quantitative evaluation method was clarified. (2) It was considered that CDF in a nuclear power plant, evaluated by using a failure rate counting the above maintenance level was quite different from CDF evaluated by using existing failure rates including a safety margin. Then, the former CDF was named as 'plant safety level' of plant system and its quantitative evaluation method was clarified. (3) Enhancing equipment maintenance level means an improvement of maintenance quality. That results in the enhancement of plant safety level. Therefore, plant safety level should be always watched as a plant performance indicator. (author)

  8. Balance between qualitative and quantitative verification methods

    International Nuclear Information System (INIS)

    Nidaira, Kazuo

    2012-01-01

    The amount of inspection effort for verification of declared nuclear material needs to be optimized in the situation where qualitative and quantitative measures are applied. Game theory was referred to investigate the relation of detection probability and deterrence of diversion. Payoffs used in the theory were quantified for cases of conventional safeguards and integrated safeguards by using AHP, Analytical Hierarchy Process. Then, it became possible to estimate detection probability under integrated safeguards which had equivalent deterrence capability for detection probability under conventional safeguards. In addition the distribution of inspection effort for qualitative and quantitative measures was estimated. Although the AHP has some ambiguities in quantifying qualitative factors, its application to optimization in safeguards is useful to reconsider the detection probabilities under integrated safeguards. (author)

  9. Full quantitative phase analysis of hydrated lime using the Rietveld method

    Energy Technology Data Exchange (ETDEWEB)

    Lassinantti Gualtieri, Magdalena, E-mail: magdalena.gualtieri@unimore.it [Dipartimento Ingegneria dei Materiali e dell' Ambiente, Universita Degli Studi di Modena e Reggio Emilia, Via Vignolese 905/a, I-41100 Modena (Italy); Romagnoli, Marcello; Miselli, Paola; Cannio, Maria [Dipartimento Ingegneria dei Materiali e dell' Ambiente, Universita Degli Studi di Modena e Reggio Emilia, Via Vignolese 905/a, I-41100 Modena (Italy); Gualtieri, Alessandro F. [Dipartimento di Scienze della Terra, Universita Degli Studi di Modena e Reggio Emilia, I-41100 Modena (Italy)

    2012-09-15

    Full quantitative phase analysis (FQPA) using X-ray powder diffraction and Rietveld refinements is a well-established method for the characterization of various hydraulic binders such as Portland cement and hydraulic limes. In this paper, the Rietveld method is applied to hydrated lime, a non-hydraulic traditional binder. The potential presence of an amorphous phase in this material is generally ignored. Both synchrotron radiation and a conventional X-ray source were used for data collection. The applicability of the developed control file for the Rietveld refinements was investigated using samples spiked with glass. The results were cross-checked by other independent methods such as thermal and chemical analyses. The sample microstructure was observed by transmission electron microscopy. It was found that the consistency between the different methods was satisfactory, supporting the validity of FQPA for this material. For the samples studied in this work, the amount of amorphous material was in the range 2-15 wt.%.

  10. Full quantitative phase analysis of hydrated lime using the Rietveld method

    International Nuclear Information System (INIS)

    Lassinantti Gualtieri, Magdalena; Romagnoli, Marcello; Miselli, Paola; Cannio, Maria; Gualtieri, Alessandro F.

    2012-01-01

    Full quantitative phase analysis (FQPA) using X-ray powder diffraction and Rietveld refinements is a well-established method for the characterization of various hydraulic binders such as Portland cement and hydraulic limes. In this paper, the Rietveld method is applied to hydrated lime, a non-hydraulic traditional binder. The potential presence of an amorphous phase in this material is generally ignored. Both synchrotron radiation and a conventional X-ray source were used for data collection. The applicability of the developed control file for the Rietveld refinements was investigated using samples spiked with glass. The results were cross-checked by other independent methods such as thermal and chemical analyses. The sample microstructure was observed by transmission electron microscopy. It was found that the consistency between the different methods was satisfactory, supporting the validity of FQPA for this material. For the samples studied in this work, the amount of amorphous material was in the range 2–15 wt.%.

  11. Qualitative research methods: key features and insights gained from use in infection prevention research.

    Science.gov (United States)

    Forman, Jane; Creswell, John W; Damschroder, Laura; Kowalski, Christine P; Krein, Sarah L

    2008-12-01

    Infection control professionals and hospital epidemiologists are accustomed to using quantitative research. Although quantitative studies are extremely important in the field of infection control and prevention, often they cannot help us explain why certain factors affect the use of infection control practices and identify the underlying mechanisms through which they do so. Qualitative research methods, which use open-ended techniques, such as interviews, to collect data and nonstatistical techniques to analyze it, provide detailed, diverse insights of individuals, useful quotes that bring a realism to applied research, and information about how different health care settings operate. Qualitative research can illuminate the processes underlying statistical correlations, inform the development of interventions, and show how interventions work to produce observed outcomes. This article describes the key features of qualitative research and the advantages that such features add to existing quantitative research approaches in the study of infection control. We address the goal of qualitative research, the nature of the research process, sampling, data collection and analysis, validity, generalizability of findings, and presentation of findings. Health services researchers are increasingly using qualitative methods to address practical problems by uncovering interacting influences in complex health care environments. Qualitative research methods, applied with expertise and rigor, can contribute important insights to infection prevention efforts.

  12. Quantitative Method to Measure Thermal Conductivity of One-Dimensional Nanostructures Based on Scanning Thermal Wave Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Bae; Chung, Jae Hun; Hwang, Gwang Seok; Jung, Eui Han; Kwon, Oh Myoung [Korea University, Seoul (Korea, Republic of)

    2014-12-15

    We present a method to quantitatively measure the thermal conductivity of one-dimensional nanostructures by utilizing scanning thermal wave microscopy (STWM) at a nanoscale spatial resolution. In this paper, we explain the principle for measuring the thermal diffusivity of one-dimensional nanostructures using STWM and the theoretical analysis procedure for quantifying the thermal diffusivity. The SWTM measurement method obtains the thermal conductivity by measuring the thermal diffusivity, which has only a phase lag relative to the distance corresponding to the transferred thermal wave. It is not affected by the thermal contact resistances between the heat source and nanostructure and between the nanostructure and probe. Thus, the heat flux applied to the nanostructure is accurately obtained. The proposed method provides a very simple and quantitative measurement relative to conventional measurement techniques.

  13. The use of Triangulation in Social Sciences Research : Can qualitative and quantitative methods be combined?

    Directory of Open Access Journals (Sweden)

    Ashatu Hussein

    2015-03-01

    Full Text Available This article refers to a study in Tanzania on fringe benefits or welfare via the work contract1 where we will work both quantitatively and qualitatively. My focus is on the vital issue of combining methods or methodologies. There has been mixed views on the uses of triangulation in researches. Some authors argue that triangulation is just for increasing the wider and deep understanding of the study phenomenon, while others have argued that triangulation is actually used to increase the study accuracy, in this case triangulation is one of the validity measures. Triangulation is defined as the use of multiple methods mainly qualitative and quantitative methods in studying the same phenomenon for the purpose of increasing study credibility. This implies that triangulation is the combination of two or more methodological approaches, theoretical perspectives, data sources, investigators and analysis methods to study the same phenomenon.However, using both qualitative and quantitative paradigms in the same study has resulted into debate from some researchers arguing that the two paradigms differ epistemologically and ontologically. Nevertheless, both paradigms are designed towards understanding about a particular subject area of interest and both of them have strengths and weaknesses. Thus, when combined there is a great possibility of neutralizing the flaws of one method and strengthening the benefits of the other for the better research results. Thus, to reap the benefits of two paradigms and minimizing the drawbacks of each, the combination of the two approaches have been advocated in this article. The quality of our studies on welfare to combat poverty is crucial, and especially when we want our conclusions to matter in practice.

  14. PCR-free quantitative detection of genetically modified organism from raw materials. An electrochemiluminescence-based bio bar code method.

    Science.gov (United States)

    Zhu, Debin; Tang, Yabing; Xing, Da; Chen, Wei R

    2008-05-15

    A bio bar code assay based on oligonucleotide-modified gold nanoparticles (Au-NPs) provides a PCR-free method for quantitative detection of nucleic acid targets. However, the current bio bar code assay requires lengthy experimental procedures including the preparation and release of bar code DNA probes from the target-nanoparticle complex and immobilization and hybridization of the probes for quantification. Herein, we report a novel PCR-free electrochemiluminescence (ECL)-based bio bar code assay for the quantitative detection of genetically modified organism (GMO) from raw materials. It consists of tris-(2,2'-bipyridyl) ruthenium (TBR)-labeled bar code DNA, nucleic acid hybridization using Au-NPs and biotin-labeled probes, and selective capture of the hybridization complex by streptavidin-coated paramagnetic beads. The detection of target DNA is realized by direct measurement of ECL emission of TBR. It can quantitatively detect target nucleic acids with high speed and sensitivity. This method can be used to quantitatively detect GMO fragments from real GMO products.

  15. Feedback for relatedness and competence : Can feedback in blended learning contribute to optimal rigor, basic needs, and motivation?

    NARCIS (Netherlands)

    Bombaerts, G.; Nickel, P.J.

    2017-01-01

    We inquire how peer and tutor feedback influences students' optimal rigor, basic needs and motivation. We analyze questionnaires from two courses in two subsequent years. We conclude that feedback in blended learning can contribute to rigor and basic needs, but it is not clear from our data what

  16. Reciprocity relations in transmission electron microscopy: A rigorous derivation.

    Science.gov (United States)

    Krause, Florian F; Rosenauer, Andreas

    2017-01-01

    A concise derivation of the principle of reciprocity applied to realistic transmission electron microscopy setups is presented making use of the multislice formalism. The equivalence of images acquired in conventional and scanning mode is thereby rigorously shown. The conditions for the applicability of the found reciprocity relations is discussed. Furthermore the positions of apertures in relation to the corresponding lenses are considered, a subject which scarcely has been addressed in previous publications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. The effect of rigor mortis on the passage of erythrocytes and fluid through the myocardium of isolated dog hearts.

    Science.gov (United States)

    Nevalainen, T J; Gavin, J B; Seelye, R N; Whitehouse, S; Donnell, M

    1978-07-01

    The effect of normal and artificially induced rigor mortis on the vascular passage of erythrocytes and fluid through isolated dog hearts was studied. Increased rigidity of 6-mm thick transmural sections through the centre of the posterior papillary muscle was used as an indication of rigor. The perfusibility of the myocardium was tested by injecting 10 ml of 1% sodium fluorescein in Hanks solution into the circumflex branch of the left coronary artery. In prerigor hearts (20 minute incubation) fluorescein perfused the myocardium evenly whether or not it was preceded by an injection of 10 ml of heparinized dog blood. Rigor mortis developed in all hearts after 90 minutes incubation or within 20 minutes of perfusing the heart with 50 ml of 5 mM iodoacetate in Hanks solution. Fluorescein injected into hearts in rigor did not enter the posterior papillary muscle and adjacent subendocardium whether or not it was preceded by heparinized blood. Thus the vascular occlusion caused by rigor in the dog heart appears to be so effective that it prevents flow into the subendocardium of small soluble ions such as fluorescein.

  18. A method to forecast quantitative variables relating to nuclear public acceptance

    International Nuclear Information System (INIS)

    Ohnishi, T.

    1992-01-01

    A methodology is proposed for forecasting the future trend of quantitative variables profoundly related to the public acceptance (PA) of nuclear energy. The social environment influencing PA is first modeled by breaking it down into a finite number of fundamental elements and then the interactive formulae between the quantitative variables, which are attributed to and characterize each element, are determined by using the actual values of the variables in the past. Inputting the estimated values of exogenous variables into these formulae, the forecast values of endogenous variables can finally be obtained. Using this method, the problem of nuclear PA in Japan is treated as, for example, where the context is considered to comprise a public sector and the general social environment and socio-psychology. The public sector is broken down into three elements of the general public, the inhabitants living around nuclear facilities and the activists of anti-nuclear movements, whereas the social environment and socio-psychological factors are broken down into several elements, such as news media and psychological factors. Twenty-seven endogenous and seven exogenous variables are introduced to quantify these elements. After quantitatively formulating the interactive features between them and extrapolating the exogenous variables into the future estimates are made of the growth or attenuation of the endogenous variables, such as the pro- and anti-nuclear fractions in public opinion polls and the frequency of occurrence of anti-nuclear movements. (author)

  19. Development of rigorous fatty acid near-infrared spectroscopy quantitation methods in support of soybean oil improvement

    Science.gov (United States)

    The seed of soybean (Glycine max L. Merr) is a valuable source of high quality edible oil and protein. Despite dramatic breeding gains over the past 80 years, soybean seed oil continues to be oxidatively unstable. Until recently, the majority of soybean oil underwent partial chemical hydrogenation. ...

  20. Credit Institutions Management Evaluation using Quantitative Methods

    Directory of Open Access Journals (Sweden)

    Nicolae Dardac

    2006-02-01

    Full Text Available Credit institutions supervising mission by state authorities is mostly assimilated with systemic risk prevention. In present, the mission is orientated on analyzing the risk profile of the credit institutions, the mechanism and existing systems as management tools providing to bank rules the proper instruments to avoid and control specific bank risks. Rating systems are sophisticated measurement instruments which are capable to assure the above objectives, such as success in banking risk management. The management quality is one of the most important elements from the set of variables used in the quoting process in credit operations. Evaluation of this quality is – generally speaking – fundamented on quantitative appreciations which can induce subjectivism and heterogeneity in quotation. The problem can be solved by using, complementary, quantitative technics such us DEA (Data Envelopment Analysis.

  1. Solution identification and quantitative analysis of fiber-capacitive drop analyzer based on multivariate statistical methods

    Science.gov (United States)

    Chen, Zhe; Qiu, Zurong; Huo, Xinming; Fan, Yuming; Li, Xinghua

    2017-03-01

    A fiber-capacitive drop analyzer is an instrument which monitors a growing droplet to produce a capacitive opto-tensiotrace (COT). Each COT is an integration of fiber light intensity signals and capacitance signals and can reflect the unique physicochemical property of a liquid. In this study, we propose a solution analytical and concentration quantitative method based on multivariate statistical methods. Eight characteristic values are extracted from each COT. A series of COT characteristic values of training solutions at different concentrations compose a data library of this kind of solution. A two-stage linear discriminant analysis is applied to analyze different solution libraries and establish discriminant functions. Test solutions can be discriminated by these functions. After determining the variety of test solutions, Spearman correlation test and principal components analysis are used to filter and reduce dimensions of eight characteristic values, producing a new representative parameter. A cubic spline interpolation function is built between the parameters and concentrations, based on which we can calculate the concentration of the test solution. Methanol, ethanol, n-propanol, and saline solutions are taken as experimental subjects in this paper. For each solution, nine or ten different concentrations are chosen to be the standard library, and the other two concentrations compose the test group. By using the methods mentioned above, all eight test solutions are correctly identified and the average relative error of quantitative analysis is 1.11%. The method proposed is feasible which enlarges the applicable scope of recognizing liquids based on the COT and improves the concentration quantitative precision, as well.

  2. Quantitative evaluation of the fault tolerance of systems important to the safety of atomic power plants

    International Nuclear Information System (INIS)

    Malkin, S.D.; Sivokon, V.P.; Shmatkova, L.V.

    1989-01-01

    Fault tolerance is the property of a system to preserve its performance upon failures of its components. Thus, in nuclear-reactor technology one has only a qualitative evaluation of fault tolerance - the single-failure criterion, which does not enable one to compare and perform goal-directed design of fault-tolerant systems, and in the field of computer technology there are no generally accepted evaluations of fault tolerance that could be applied effectively to reactor systems. This paper considers alternative evaluations of fault tolerance and a method of comprehensive automated calculation of the reliability and fault tolerance of complex systems. The authors presented quantitative estimates of fault tolerance that develop the single-failure criterion. They have limiting processes that allow simple and graphical standardization. They worked out a method and a program for comprehensive calculation of the reliability and fault tolerance of systems of complex structure that are important to the safety of atomic power plants. The quantitative evaluation of the fault tolerance of these systems exhibits a degree of insensitivity to failures and shows to what extent their reliability is determined by a rigorously defined structure, and to what extent by the probabilistic reliability characteristics of the components. To increase safety, one must increase the fault tolerance of the most important systems of atomic power plants

  3. Quantitative functional scintigraphy of the salivary glands: A new method of interpreting and clinical results

    International Nuclear Information System (INIS)

    Schneider, P.; Trauring, G.; Haas, J.P.; Noodt, A.; Draf, W.

    1984-01-01

    Tc-99m pertechnetate is injected i.v. and the kinetics of the tracer in the salivary glands is analyzed using a gamma camera and a computer system. To visualize regional gland function, phase images as well as socalled gradient images are generated, which reflect the rate of tracer inflow and outflow. The time activity curves for the individual glands which are obtained with the ROI technique show an initial rise which reflects the pertechnetate uptake potential of the gland and is superimposed by background activity. After a standardized lemon juice dose the curve drops steeply, with the slope depending on the outflow potential of the gland and the background activity. In the past, attempts at quantifying the uptake and elimination functions have failed because of problems in allowing for the variable background component of the time activity curves, which normally amounts of about 60%. In 25 patients in whom one gland had been removed surgically the background activity was examined in terms of the time course and the regional pattern and a patient and gland-specific subtraction method was developed for visualizing the time activity curves of isolated glands devoid of any background activity and describing the uptake and elimination potentials in quantitative terms. Using this new method we evaluated 305 salivary gland scans. Normal ranges for the quantitative parameters were established and their reproducibility was examined. Unlike qualitative functional images of the salivary glands the new quantitative method offers accurate evidence of the extent of gland function and thus helps to decide wether a gland should be salvaged or not (conservative versus surgical treatment). However, quantitation does not furnish any clues on the benign or malignant nature of a tumor. (Author)

  4. A validated method for the quantitation of 1,1-difluoroethane using a gas in equilibrium method of calibration.

    Science.gov (United States)

    Avella, Joseph; Lehrer, Michael; Zito, S William

    2008-10-01

    1,1-Difluoroethane (DFE), also known as Freon 152A, is a member of a class of compounds known as halogenated hydrocarbons. A number of these compounds have gained notoriety because of their ability to induce rapid onset of intoxication after inhalation exposure. Abuse of DFE has necessitated development of methods for its detection and quantitation in postmortem and human performance specimens. Furthermore, methodologies applicable to research studies are required as there have been limited toxicokinetic and toxicodynamic reports published on DFE. This paper describes a method for the quantitation of DFE using a gas chromatography-flame-ionization headspace technique that employs solventless standards for calibration. Two calibration curves using 0.5 mL whole blood calibrators which ranged from A: 0.225-1.350 to B: 9.0-180.0 mg/L were developed. These were evaluated for linearity (0.9992 and 0.9995), limit of detection of 0.018 mg/L, limit of quantitation of 0.099 mg/L (recovery 111.9%, CV 9.92%), and upper limit of linearity of 27,000.0 mg/L. Combined curve recovery results of a 98.0 mg/L DFE control that was prepared using an alternate technique was 102.2% with CV of 3.09%. No matrix interference was observed in DFE enriched blood, urine or brain specimens nor did analysis of variance detect any significant differences (alpha = 0.01) in the area under the curve of blood, urine or brain specimens at three identical DFE concentrations. The method is suitable for use in forensic laboratories because validation was performed on instrumentation routinely used in forensic labs and due to the ease with which the calibration range can be adjusted. Perhaps more importantly it is also useful for research oriented studies because the removal of solvent from standard preparation eliminates the possibility for solvent induced changes to the gas/liquid partitioning of DFE or chromatographic interference due to the presence of solvent in specimens.

  5. Integrating Quantitative and Qualitative Results in Health Science Mixed Methods Research Through Joint Displays

    Science.gov (United States)

    Guetterman, Timothy C.; Fetters, Michael D.; Creswell, John W.

    2015-01-01

    PURPOSE Mixed methods research is becoming an important methodology to investigate complex health-related topics, yet the meaningful integration of qualitative and quantitative data remains elusive and needs further development. A promising innovation to facilitate integration is the use of visual joint displays that bring data together visually to draw out new insights. The purpose of this study was to identify exemplar joint displays by analyzing the various types of joint displays being used in published articles. METHODS We searched for empirical articles that included joint displays in 3 journals that publish state-of-the-art mixed methods research. We analyzed each of 19 identified joint displays to extract the type of display, mixed methods design, purpose, rationale, qualitative and quantitative data sources, integration approaches, and analytic strategies. Our analysis focused on what each display communicated and its representation of mixed methods analysis. RESULTS The most prevalent types of joint displays were statistics-by-themes and side-by-side comparisons. Innovative joint displays connected findings to theoretical frameworks or recommendations. Researchers used joint displays for convergent, explanatory sequential, exploratory sequential, and intervention designs. We identified exemplars for each of these designs by analyzing the inferences gained through using the joint display. Exemplars represented mixed methods integration, presented integrated results, and yielded new insights. CONCLUSIONS Joint displays appear to provide a structure to discuss the integrated analysis and assist both researchers and readers in understanding how mixed methods provides new insights. We encourage researchers to use joint displays to integrate and represent mixed methods analysis and discuss their value. PMID:26553895

  6. Application of new least-squares methods for the quantitative infrared analysis of multicomponent samples

    International Nuclear Information System (INIS)

    Haaland, D.M.; Easterling, R.G.

    1982-01-01

    Improvements have been made in previous least-squares regression analyses of infrared spectra for the quantitative estimation of concentrations of multicomponent mixtures. Spectral baselines are fitted by least-squares methods, and overlapping spectral features are accounted for in the fitting procedure. Selection of peaks above a threshold value reduces computation time and data storage requirements. Four weighted least-squares methods incorporating different baseline assumptions were investigated using FT-IR spectra of the three pure xylene isomers and their mixtures. By fitting only regions of the spectra that follow Beer's Law, accurate results can be obtained using three of the fitting methods even when baselines are not corrected to zero. Accurate results can also be obtained using one of the fits even in the presence of Beer's Law deviations. This is a consequence of pooling the weighted results for each spectral peak such that the greatest weighting is automatically given to those peaks that adhere to Beer's Law. It has been shown with the xylene spectra that semiquantitative results can be obtained even when all the major components are not known or when expected components are not present. This improvement over previous methods greatly expands the utility of quantitative least-squares analyses

  7. Rigorous results on measuring the quark charge below color threshold

    International Nuclear Information System (INIS)

    Lipkin, H.J.

    1979-01-01

    Rigorous theorems are presented showing that contributions from a color nonsinglet component of the current to matrix elements of a second order electromagnetic transition are suppressed by factors inversely proportional to the energy of the color threshold. Parton models which obtain matrix elements proportional to the color average of the square of the quark charge are shown to neglect terms of the same order of magnitude as terms kept. (author)

  8. Nuclear medicine and imaging research. Instrumentation and quantitative methods of evaluation. Progress report, January 15, 1985-January 14, 1986

    International Nuclear Information System (INIS)

    Beck, R.N.; Cooper, M.D.

    1985-09-01

    This program of research addresses problems involving the basic science and technology of radioactive tracer methods as they relate to nuclear medicine and imaging. The broad goal is to develop new instruments and methods for image formation, processing, quantitation, and display, so as to maximize the diagnostic information per unit of absorbed radiation dose to the patient. These developments are designed to meet the needs imposed by new radiopharmaceuticals developed to solve specific biomedical problems, as well as to meet the instrumentation needs associated with radiopharmaceutical production and quantitative clinical feasibility studies of the brain with PET VI. Project I addresses problems associated with the quantitative imaging of single-photon emitters; Project II addresses similar problems associated with the quantitative imaging of positron emitters; Project III addresses methodological problems associated with the quantitative evaluation of the efficacy of diagnostic imaging procedures. The original proposal covered work to be carried out over the three-year contract period. This report covers progress made during Year Three. 36 refs., 1 tab

  9. A probabilistic method for computing quantitative risk indexes from medical injuries compensation claims.

    Science.gov (United States)

    Dalle Carbonare, S; Folli, F; Patrini, E; Giudici, P; Bellazzi, R

    2013-01-01

    The increasing demand of health care services and the complexity of health care delivery require Health Care Organizations (HCOs) to approach clinical risk management through proper methods and tools. An important aspect of risk management is to exploit the analysis of medical injuries compensation claims in order to reduce adverse events and, at the same time, to optimize the costs of health insurance policies. This work provides a probabilistic method to estimate the risk level of a HCO by computing quantitative risk indexes from medical injury compensation claims. Our method is based on the estimate of a loss probability distribution from compensation claims data through parametric and non-parametric modeling and Monte Carlo simulations. The loss distribution can be estimated both on the whole dataset and, thanks to the application of a Bayesian hierarchical model, on stratified data. The approach allows to quantitatively assessing the risk structure of the HCO by analyzing the loss distribution and deriving its expected value and percentiles. We applied the proposed method to 206 cases of injuries with compensation requests collected from 1999 to the first semester of 2007 by the HCO of Lodi, in the Northern part of Italy. We computed the risk indexes taking into account the different clinical departments and the different hospitals involved. The approach proved to be useful to understand the HCO risk structure in terms of frequency, severity, expected and unexpected loss related to adverse events.

  10. Levels of reconstruction as complementarity in mixed methods research: a social theory-based conceptual framework for integrating qualitative and quantitative research.

    Science.gov (United States)

    Carroll, Linda J; Rothe, J Peter

    2010-09-01

    Like other areas of health research, there has been increasing use of qualitative methods to study public health problems such as injuries and injury prevention. Likewise, the integration of qualitative and quantitative research (mixed-methods) is beginning to assume a more prominent role in public health studies. Likewise, using mixed-methods has great potential for gaining a broad and comprehensive understanding of injuries and their prevention. However, qualitative and quantitative research methods are based on two inherently different paradigms, and their integration requires a conceptual framework that permits the unity of these two methods. We present a theory-driven framework for viewing qualitative and quantitative research, which enables us to integrate them in a conceptually sound and useful manner. This framework has its foundation within the philosophical concept of complementarity, as espoused in the physical and social sciences, and draws on Bergson's metaphysical work on the 'ways of knowing'. Through understanding how data are constructed and reconstructed, and the different levels of meaning that can be ascribed to qualitative and quantitative findings, we can use a mixed-methods approach to gain a conceptually sound, holistic knowledge about injury phenomena that will enhance our development of relevant and successful interventions.

  11. A Simple Linear Regression Method for Quantitative Trait Loci Linkage Analysis With Censored Observations

    OpenAIRE

    Anderson, Carl A.; McRae, Allan F.; Visscher, Peter M.

    2006-01-01

    Standard quantitative trait loci (QTL) mapping techniques commonly assume that the trait is both fully observed and normally distributed. When considering survival or age-at-onset traits these assumptions are often incorrect. Methods have been developed to map QTL for survival traits; however, they are both computationally intensive and not available in standard genome analysis software packages. We propose a grouped linear regression method for the analysis of continuous survival data. Using...

  12. Rigor mortis development in turkey breast muscle and the effect of electrical stunning.

    Science.gov (United States)

    Alvarado, C Z; Sams, A R

    2000-11-01

    Rigor mortis development in turkey breast muscle and the effect of electrical stunning on this process are not well characterized. Some electrical stunning procedures have been known to inhibit postmortem (PM) biochemical reactions, thereby delaying the onset of rigor mortis in broilers. Therefore, this study was designed to characterize rigor mortis development in stunned and unstunned turkeys. A total of 154 turkey toms in two trials were conventionally processed at 20 to 22 wk of age. Turkeys were either stunned with a pulsed direct current (500 Hz, 50% duty cycle) at 35 mA (40 V) in a saline bath for 12 seconds or left unstunned as controls. At 15 min and 1, 2, 4, 8, 12, and 24 h PM, pectoralis samples were collected to determine pH, R-value, L* value, sarcomere length, and shear value. In Trial 1, the samples obtained for pH, R-value, and sarcomere length were divided into surface and interior samples. There were no significant differences between the surface and interior samples among any parameters measured. Muscle pH significantly decreased over time in stunned and unstunned birds through 2 h PM. The R-values increased to 8 h PM in unstunned birds and 24 h PM in stunned birds. The L* values increased over time, with no significant differences after 1 h PM for the controls and 2 h PM for the stunned birds. Sarcomere length increased through 2 h PM in the controls and 12 h PM in the stunned fillets. Cooked meat shear values decreased through the 1 h PM deboning time in the control fillets and 2 h PM in the stunned fillets. These results suggest that stunning delayed the development of rigor mortis through 2 h PM, but had no significant effect on the measured parameters at later time points, and that deboning turkey breasts at 2 h PM or later will not significantly impair meat tenderness.

  13. QACD: A method for the quantitative assessment of compositional distribution in geologic materials

    Science.gov (United States)

    Loocke, M. P.; Lissenberg, J. C. J.; MacLeod, C. J.

    2017-12-01

    In order to fully understand the petrogenetic history of a rock, it is critical to obtain a thorough characterization of the chemical and textural relationships of its mineral constituents. Element mapping combines the microanalytical techniques that allow for the analysis of major- and minor elements at high spatial resolutions (e.g., electron microbeam analysis) with 2D mapping of samples in order to provide unprecedented detail regarding the growth histories and compositional distributions of minerals within a sample. We present a method for the acquisition and processing of large area X-ray element maps obtained by energy-dispersive X-ray spectrometer (EDS) to produce a quantitative assessment of compositional distribution (QACD) of mineral populations within geologic materials. By optimizing the conditions at which the EDS X-ray element maps are acquired, we are able to obtain full thin section quantitative element maps for most major elements in relatively short amounts of time. Such maps can be used to not only accurately identify all phases and calculate mineral modes for a sample (e.g., a petrographic thin section), but, critically, enable a complete quantitative assessment of their compositions. The QACD method has been incorporated into a python-based, easy-to-use graphical user interface (GUI) called Quack. The Quack software facilitates the generation of mineral modes, element and molar ratio maps and the quantification of full-sample compositional distributions. The open-source nature of the Quack software provides a versatile platform which can be easily adapted and modified to suit the needs of the user.

  14. A comparison of quantitative methods for clinical imaging with hyperpolarized (13)C-pyruvate.

    Science.gov (United States)

    Daniels, Charlie J; McLean, Mary A; Schulte, Rolf F; Robb, Fraser J; Gill, Andrew B; McGlashan, Nicholas; Graves, Martin J; Schwaiger, Markus; Lomas, David J; Brindle, Kevin M; Gallagher, Ferdia A

    2016-04-01

    Dissolution dynamic nuclear polarization (DNP) enables the metabolism of hyperpolarized (13)C-labelled molecules, such as the conversion of [1-(13)C]pyruvate to [1-(13)C]lactate, to be dynamically and non-invasively imaged in tissue. Imaging of this exchange reaction in animal models has been shown to detect early treatment response and correlate with tumour grade. The first human DNP study has recently been completed, and, for widespread clinical translation, simple and reliable methods are necessary to accurately probe the reaction in patients. However, there is currently no consensus on the most appropriate method to quantify this exchange reaction. In this study, an in vitro system was used to compare several kinetic models, as well as simple model-free methods. Experiments were performed using a clinical hyperpolarizer, a human 3 T MR system, and spectroscopic imaging sequences. The quantitative methods were compared in vivo by using subcutaneous breast tumours in rats to examine the effect of pyruvate inflow. The two-way kinetic model was the most accurate method for characterizing the exchange reaction in vitro, and the incorporation of a Heaviside step inflow profile was best able to describe the in vivo data. The lactate time-to-peak and the lactate-to-pyruvate area under the curve ratio were simple model-free approaches that accurately represented the full reaction, with the time-to-peak method performing indistinguishably from the best kinetic model. Finally, extracting data from a single pixel was a robust and reliable surrogate of the whole region of interest. This work has identified appropriate quantitative methods for future work in the analysis of human hyperpolarized (13)C data. © 2016 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

  15. Quantitative investment analysis

    CERN Document Server

    DeFusco, Richard

    2007-01-01

    In the "Second Edition" of "Quantitative Investment Analysis," financial experts Richard DeFusco, Dennis McLeavey, Jerald Pinto, and David Runkle outline the tools and techniques needed to understand and apply quantitative methods to today's investment process.

  16. Comparison of two label-free global quantitation methods, APEX and 2D gel electrophoresis, applied to the Shigella dysenteriae proteome

    Directory of Open Access Journals (Sweden)

    Fleischmann Robert D

    2009-06-01

    Full Text Available Abstract The in vitro stationary phase proteome of the human pathogen Shigella dysenteriae serotype 1 (SD1 was quantitatively analyzed in Coomassie Blue G250 (CBB-stained 2D gels. More than four hundred and fifty proteins, of which 271 were associated with distinct gel spots, were identified. In parallel, we employed 2D-LC-MS/MS followed by the label-free computationally modified spectral counting method APEX for absolute protein expression measurements. Of the 4502 genome-predicted SD1 proteins, 1148 proteins were identified with a false positive discovery rate of 5% and quantitated using 2D-LC-MS/MS and APEX. The dynamic range of the APEX method was approximately one order of magnitude higher than that of CBB-stained spot intensity quantitation. A squared Pearson correlation analysis revealed a reasonably good correlation (R2 = 0.67 for protein quantities surveyed by both methods. The correlation was decreased for protein subsets with specific physicochemical properties, such as low Mr values and high hydropathy scores. Stoichiometric ratios of subunits of protein complexes characterized in E. coli were compared with APEX quantitative ratios of orthologous SD1 protein complexes. A high correlation was observed for subunits of soluble cellular protein complexes in several cases, demonstrating versatile applications of the APEX method in quantitative proteomics.

  17. Rigorous Integration of Non-Linear Ordinary Differential Equations in Chebyshev Basis

    Czech Academy of Sciences Publication Activity Database

    Dzetkulič, Tomáš

    2015-01-01

    Roč. 69, č. 1 (2015), s. 183-205 ISSN 1017-1398 R&D Projects: GA MŠk OC10048; GA ČR GD201/09/H057 Institutional research plan: CEZ:AV0Z10300504 Keywords : Initial value problem * Rigorous integration * Taylor model * Chebyshev basis Subject RIV: IN - Informatics, Computer Science Impact factor: 1.366, year: 2015

  18. Development and evaluation of event-specific quantitative PCR method for genetically modified soybean A2704-12.

    Science.gov (United States)

    Takabatake, Reona; Akiyama, Hiroshi; Sakata, Kozue; Onishi, Mari; Koiwa, Tomohiro; Futo, Satoshi; Minegishi, Yasutaka; Teshima, Reiko; Mano, Junichi; Furui, Satoshi; Kitta, Kazumi

    2011-01-01

    A novel real-time PCR-based analytical method was developed for the event-specific quantification of a genetically modified (GM) soybean event; A2704-12. During the plant transformation, DNA fragments derived from pUC19 plasmid were integrated in A2704-12, and the region was found to be A2704-12 specific. The pUC19-derived DNA sequences were used as primers for the specific detection of A2704-12. We first tried to construct a standard plasmid for A2704-12 quantification using pUC19. However, non-specific signals appeared with both qualitative and quantitative PCR analyses using the specific primers with pUC19 as a template, and we then constructed a plasmid using pBR322. The conversion factor (C(f)), which is required to calculate the amount of the genetically modified organism (GMO), was experimentally determined with two real-time PCR instruments, the Applied Biosystems 7900HT and the Applied Biosystems 7500. The determined C(f) values were both 0.98. The quantitative method was evaluated by means of blind tests in multi-laboratory trials using the two real-time PCR instruments. The limit of quantitation for the method was estimated to be 0.1%. The trueness and precision were evaluated as the bias and reproducibility of relative standard deviation (RSD(R)), and the determined bias and RSD(R) values for the method were each less than 20%. These results suggest that the developed method would be suitable for practical analyses for the detection and quantification of A2704-12.

  19. Quantitative method for measurement of the Goos-Hanchen effect based on source divergence considerations

    International Nuclear Information System (INIS)

    Gray, Jeffrey F.; Puri, Ashok

    2007-01-01

    In this paper we report on a method for quantitative measurement and characterization of the Goos-Hanchen effect based upon the real world performance of optical sources. A numerical model of a nonideal plane wave is developed in terms of uniform divergence properties. This model is applied to the Goos-Hanchen shift equations to determine beam shift displacement characteristics, which provides quantitative estimates of finite shifts near critical angle. As a potential technique for carrying out a meaningful comparison with experiments, a classical method of edge detection is discussed. To this end a line spread Green's function is defined which can be used to determine the effective transfer function of the near critical angle behavior of divergent plane waves. The process yields a distributed (blurred) output with a line spread function characteristic of the inverse square root nature of the Goos-Hanchen shift equation. A parameter of interest for measurement is given by the edge shift function. Modern imaging and image processing methods provide suitable techniques for exploiting the edge shift phenomena to attain refractive index sensitivities of the order of 10 -6 , comparable with the recent results reported in the literature

  20. A Quantitative Reasoning Approach to Algebra Using Inquiry-Based Learning

    Directory of Open Access Journals (Sweden)

    Victor I. Piercey

    2017-07-01

    Full Text Available In this paper, I share a hybrid quantitative reasoning/algebra two-course sequence that challenges the common assumption that quantitative literacy and reasoning are less rigorous mathematics alternatives to algebra and illustrates that a quantitative reasoning framework can be used to teach traditional algebra. The presentation is made in two parts. In the first part, which is somewhat philosophical and theoretical, I explain my personal perspective of what I mean by “algebra” and “doing algebra.” I contend that algebra is a form of communication whose value is precision, which allows us to perform algebraic manipulations in the form of simplification and solving moves. A quantitative reasoning approach to traditional algebraic manipulations rests on intentional and purposeful use of simplification and solving moves within contextual situations. In part 2, I describe a 6-week instructional module intended for undergraduate business students that was delivered to students who had placed into beginning algebra. The perspective described in part 1 heavily informed the design of this module. The course materials, which involve the use of Excel in multiple authentic contexts, are built around the use of inquiry-based learning. Upon completion of this module, the percentage of students who successfully complete model problems in an assessment is in the same range as surveyed students in precalculus and calculus, approximately two “grade levels” ahead of their placement.

  1. Rigorous quantum limits on monitoring free masses and harmonic oscillators

    Science.gov (United States)

    Roy, S. M.

    2018-03-01

    There are heuristic arguments proposing that the accuracy of monitoring position of a free mass m is limited by the standard quantum limit (SQL): σ2( X (t ) ) ≥σ2( X (0 ) ) +(t2/m2) σ2( P (0 ) ) ≥ℏ t /m , where σ2( X (t ) ) and σ2( P (t ) ) denote variances of the Heisenberg representation position and momentum operators. Yuen [Phys. Rev. Lett. 51, 719 (1983), 10.1103/PhysRevLett.51.719] discovered that there are contractive states for which this result is incorrect. Here I prove universally valid rigorous quantum limits (RQL), viz. rigorous upper and lower bounds on σ2( X (t ) ) in terms of σ2( X (0 ) ) and σ2( P (0 ) ) , given by Eq. (12) for a free mass and by Eq. (36) for an oscillator. I also obtain the maximally contractive and maximally expanding states which saturate the RQL, and use the contractive states to set up an Ozawa-type measurement theory with accuracies respecting the RQL but beating the standard quantum limit. The contractive states for oscillators improve on the Schrödinger coherent states of constant variance and may be useful for gravitational wave detection and optical communication.

  2. Parent Management Training-Oregon Model: Adapting Intervention with Rigorous Research.

    Science.gov (United States)

    Forgatch, Marion S; Kjøbli, John

    2016-09-01

    Parent Management Training-Oregon Model (PMTO(®) ) is a set of theory-based parenting programs with status as evidence-based treatments. PMTO has been rigorously tested in efficacy and effectiveness trials in different contexts, cultures, and formats. Parents, the presumed agents of change, learn core parenting practices, specifically skill encouragement, limit setting, monitoring/supervision, interpersonal problem solving, and positive involvement. The intervention effectively prevents and ameliorates children's behavior problems by replacing coercive interactions with positive parenting practices. Delivery format includes sessions with individual families in agencies or families' homes, parent groups, and web-based and telehealth communication. Mediational models have tested parenting practices as mechanisms of change for children's behavior and found support for the theory underlying PMTO programs. Moderating effects include children's age, maternal depression, and social disadvantage. The Norwegian PMTO implementation is presented as an example of how PMTO has been tailored to reach diverse populations as delivered by multiple systems of care throughout the nation. An implementation and research center in Oslo provides infrastructure and promotes collaboration between practitioners and researchers to conduct rigorous intervention research. Although evidence-based and tested within a wide array of contexts and populations, PMTO must continue to adapt to an ever-changing world. © 2016 Family Process Institute.

  3. Rigor force responses of permeabilized fibres from fast and slow skeletal muscles of aged rats.

    Science.gov (United States)

    Plant, D R; Lynch, G S

    2001-09-01

    1. Ageing is generally associated with a decline in skeletal muscle mass and strength and a slowing of muscle contraction, factors that impact upon the quality of life for the elderly. The mechanisms underlying this age-related muscle weakness have not been fully resolved. The purpose of the present study was to determine whether the decrease in muscle force as a consequence of age could be attributed partly to a decrease in the number of cross-bridges participating during contraction. 2. Given that the rigor force is proportional to the approximate total number of interacting sites between the actin and myosin filaments, we tested the null hypothesis that the rigor force of permeabilized muscle fibres from young and old rats would not be different. 3. Permeabilized fibres from the extensor digitorum longus (fast-twitch; EDL) and soleus (predominantly slow-twitch) muscles of young (6 months of age) and old (27 months of age) male F344 rats were activated in Ca2+-buffered solutions to determine force-pCa characteristics (where pCa = -log(10)[Ca2+]) and then in solutions lacking ATP and Ca2+ to determine rigor force levels. 4. The rigor forces for EDL and soleus muscle fibres were not different between young and old rats, indicating that the approximate total number of cross-bridges that can be formed between filaments did not decline with age. We conclude that the age-related decrease in force output is more likely attributed to a decrease in the force per cross-bridge and/or decreases in the efficiency of excitation-contraction coupling.

  4. Quantitative analysis of Tl-201 myocardial perfusion image with special reference to circumferential profile method

    Energy Technology Data Exchange (ETDEWEB)

    Miyanaga, Hajime [Kyoto Prefectural Univ. of Medicine (Japan)

    1982-08-01

    A quantitative analysis of thallium-201 myocardial perfusion image (MPI) was attempted by using circumferential profile method (CPM) and the first purpose of this study is to assess the clinical utility of this method for the detection of myocardial ischemia. In patients with coronary artery disease, CPM analysis to exercise T1-MPI showed high sensitivity (9/12, 75%) and specificity (9/9, 100%), whereas exercise ECG showed high sensitivity (9/12, 75%), but relatively low specificity (7/9, 78%). In patients with myocardial infarction, CPM also showed high sensitivity (34/38, 89%) for the detection of myocardial necrosis, compared with visual interpretation (31/38, 81%) and with ECG (31/38, 81%). Defect score was correlated well with the number of abnormal Q waves. In exercise study, CPM was also sensitive to the change of perfusion defect in T1-MPI produced by exercise. So the results indicate that CPM is a good method not only quantitatively but also objectively to analyze T1-MPI. Although ECG is the most commonly used diagnostic tool for ischemic heart disease, several exercise induced ischemic changes in ECG have been still on discussion as criteria. So the second purpose of this study is to evaluate these ischemic ECG changes by exercise T1-MPI analized quantitatively. ST depression (ischemic 1 mm and junctional 2 mm or more), ST elevation (1 mm or more), and coronary T wave reversion in exercise ECG were though to be ischemic changes.

  5. Integrating Quantitative and Qualitative Results in Health Science Mixed Methods Research Through Joint Displays.

    Science.gov (United States)

    Guetterman, Timothy C; Fetters, Michael D; Creswell, John W

    2015-11-01

    Mixed methods research is becoming an important methodology to investigate complex health-related topics, yet the meaningful integration of qualitative and quantitative data remains elusive and needs further development. A promising innovation to facilitate integration is the use of visual joint displays that bring data together visually to draw out new insights. The purpose of this study was to identify exemplar joint displays by analyzing the various types of joint displays being used in published articles. We searched for empirical articles that included joint displays in 3 journals that publish state-of-the-art mixed methods research. We analyzed each of 19 identified joint displays to extract the type of display, mixed methods design, purpose, rationale, qualitative and quantitative data sources, integration approaches, and analytic strategies. Our analysis focused on what each display communicated and its representation of mixed methods analysis. The most prevalent types of joint displays were statistics-by-themes and side-by-side comparisons. Innovative joint displays connected findings to theoretical frameworks or recommendations. Researchers used joint displays for convergent, explanatory sequential, exploratory sequential, and intervention designs. We identified exemplars for each of these designs by analyzing the inferences gained through using the joint display. Exemplars represented mixed methods integration, presented integrated results, and yielded new insights. Joint displays appear to provide a structure to discuss the integrated analysis and assist both researchers and readers in understanding how mixed methods provides new insights. We encourage researchers to use joint displays to integrate and represent mixed methods analysis and discuss their value. © 2015 Annals of Family Medicine, Inc.

  6. Quantitative methods for developing C2 system requirement

    Energy Technology Data Exchange (ETDEWEB)

    Tyler, K.K.

    1992-06-01

    The US Army established the Army Tactical Command and Control System (ATCCS) Experimentation Site (AES) to provide a place where material and combat developers could experiment with command and control systems. The AES conducts fundamental and applied research involving command and control issues using a number of research methods, ranging from large force-level experiments, to controlled laboratory experiments, to studies and analyses. The work summarized in this paper was done by Pacific Northwest Laboratory under task order from the Army Tactical Command and Control System Experimentation Site. The purpose of the task was to develop the functional requirements for army engineer automation and support software, including MCS-ENG. A client, such as an army engineer, has certain needs and requirements of his or her software; these needs must be presented in ways that are readily understandable to the software developer. A requirements analysis then, such as the one described in this paper, is simply the means of communication between those who would use a piece of software and those who would develop it. The analysis from which this paper was derived attempted to bridge the ``communications gap`` between army combat engineers and software engineers. It sought to derive and state the software needs of army engineers in ways that are meaningful to software engineers. In doing this, it followed a natural sequence of investigation: (1) what does an army engineer do, (2) with which tasks can software help, (3) how much will it cost, and (4) where is the highest payoff? This paper demonstrates how each of these questions was addressed during an analysis of the functional requirements of engineer support software. Systems engineering methods are used in a task analysis and a quantitative scoring method was developed to score responses regarding the feasibility of task automation. The paper discusses the methods used to perform utility and cost-benefits estimates.

  7. A novel baseline correction method using convex optimization framework in laser-induced breakdown spectroscopy quantitative analysis

    Science.gov (United States)

    Yi, Cancan; Lv, Yong; Xiao, Han; Ke, Ke; Yu, Xun

    2017-12-01

    For laser-induced breakdown spectroscopy (LIBS) quantitative analysis technique, baseline correction is an essential part for the LIBS data preprocessing. As the widely existing cases, the phenomenon of baseline drift is generated by the fluctuation of laser energy, inhomogeneity of sample surfaces and the background noise, which has aroused the interest of many researchers. Most of the prevalent algorithms usually need to preset some key parameters, such as the suitable spline function and the fitting order, thus do not have adaptability. Based on the characteristics of LIBS, such as the sparsity of spectral peaks and the low-pass filtered feature of baseline, a novel baseline correction and spectral data denoising method is studied in this paper. The improved technology utilizes convex optimization scheme to form a non-parametric baseline correction model. Meanwhile, asymmetric punish function is conducted to enhance signal-noise ratio (SNR) of the LIBS signal and improve reconstruction precision. Furthermore, an efficient iterative algorithm is applied to the optimization process, so as to ensure the convergence of this algorithm. To validate the proposed method, the concentration analysis of Chromium (Cr),Manganese (Mn) and Nickel (Ni) contained in 23 certified high alloy steel samples is assessed by using quantitative models with Partial Least Squares (PLS) and Support Vector Machine (SVM). Because there is no prior knowledge of sample composition and mathematical hypothesis, compared with other methods, the method proposed in this paper has better accuracy in quantitative analysis, and fully reflects its adaptive ability.

  8. Preliminary research on quantitative methods of water resources carrying capacity based on water resources balance sheet

    Science.gov (United States)

    Wang, Yanqiu; Huang, Xiaorong; Gao, Linyun; Guo, Biying; Ma, Kai

    2018-06-01

    Water resources are not only basic natural resources, but also strategic economic resources and ecological control factors. Water resources carrying capacity constrains the sustainable development of regional economy and society. Studies of water resources carrying capacity can provide helpful information about how the socioeconomic system is both supported and restrained by the water resources system. Based on the research of different scholars, major problems in the study of water resources carrying capacity were summarized as follows: the definition of water resources carrying capacity is not yet unified; the methods of carrying capacity quantification based on the definition of inconsistency are poor in operability; the current quantitative research methods of water resources carrying capacity did not fully reflect the principles of sustainable development; it is difficult to quantify the relationship among the water resources, economic society and ecological environment. Therefore, it is necessary to develop a better quantitative evaluation method to determine the regional water resources carrying capacity. This paper proposes a new approach to quantifying water resources carrying capacity (that is, through the compilation of the water resources balance sheet) to get a grasp of the regional water resources depletion and water environmental degradation (as well as regional water resources stock assets and liabilities), figure out the squeeze of socioeconomic activities on the environment, and discuss the quantitative calculation methods and technical route of water resources carrying capacity which are able to embody the substance of sustainable development.

  9. A comparison of ancestral state reconstruction methods for quantitative characters.

    Science.gov (United States)

    Royer-Carenzi, Manuela; Didier, Gilles

    2016-09-07

    Choosing an ancestral state reconstruction method among the alternatives available for quantitative characters may be puzzling. We present here a comparison of seven of them, namely the maximum likelihood, restricted maximum likelihood, generalized least squares under Brownian, Brownian-with-trend and Ornstein-Uhlenbeck models, phylogenetic independent contrasts and squared parsimony methods. A review of the relations between these methods shows that the maximum likelihood, the restricted maximum likelihood and the generalized least squares under Brownian model infer the same ancestral states and can only be distinguished by the distributions accounting for the reconstruction uncertainty which they provide. The respective accuracy of the methods is assessed over character evolution simulated under a Brownian motion with (and without) directional or stabilizing selection. We give the general form of ancestral state distributions conditioned on leaf states under the simulation models. Ancestral distributions are used first, to give a theoretical lower bound of the expected reconstruction error, and second, to develop an original evaluation scheme which is more efficient than comparing the reconstructed and the simulated states. Our simulations show that: (i) the distributions of the reconstruction uncertainty provided by the methods generally make sense (some more than others); (ii) it is essential to detect the presence of an evolutionary trend and to choose a reconstruction method accordingly; (iii) all the methods show good performances on characters under stabilizing selection; (iv) without trend or stabilizing selection, the maximum likelihood method is generally the most accurate. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Nuclear medicine and image research: instrumentation and quantitative methods of evaluation. Comprehensive 3-year progress report, January 15, 1983-January 14, 1986

    International Nuclear Information System (INIS)

    Beck, R.N.; Cooper, M.D.

    1985-09-01

    This program of research addresses problems involving the basic science and technology of radioactive tracer methods as they relate to nuclear medicine and imaging. The broad goal is to develop new instruments and methods for image formation, processing, quantitation, and display, so as to maximize the diagnostic information per unit of absorbed radiation dose to the patient. Project I addresses problems with the quantitative imaging a single-photon emitters; Project II addresses similar problems associated with the quantitative imaging of positron emitters; Project III addresses methodological problems associated with the quantitative evaluation of the efficacy of diagnostic imaging procedures

  11. An improved method for quantitative magneto-optical analysis of superconductors

    International Nuclear Information System (INIS)

    Laviano, F; Botta, D; Chiodoni, A; Gerbaldo, R; Ghigo, G; Gozzelino, L; Zannella, S; Mezzetti, E

    2003-01-01

    We report on the analysis method to extract quantitative local electrodynamics in superconductors by means of the magneto-optical technique. First of all, we discuss the calibration procedure to convert the local light intensity values into magnetic induction field distribution and start focusing on the role played by the generally disregarded magnetic induction components parallel to the indicator film plane (in-plane field effect). To account for the reliability of the whole technique, the method used to reconstruct the electrical current density distribution is reported, together with a numerical test example. The methodology is applied to measure local magnetic field and current distributions on a typical YBa 2 Cu 3 O 7-x good quality film. We show how the in-plane field influences the MO measurements, after which we present an algorithm to account for the in-plane field components. The meaningful impact of the correction on the experimental results is shown. Afterwards, we discuss some aspects about the electrodynamics of the superconducting sample

  12. Web Applications Vulnerability Management using a Quantitative Stochastic Risk Modeling Method

    Directory of Open Access Journals (Sweden)

    Sergiu SECHEL

    2017-01-01

    Full Text Available The aim of this research is to propose a quantitative risk modeling method that reduces the guess work and uncertainty from the vulnerability and risk assessment activities of web based applications while providing users the flexibility to assess risk according to their risk appetite and tolerance with a high degree of assurance. The research method is based on the research done by the OWASP Foundation on this subject but their risk rating methodology needed de-bugging and updates in different in key areas that are presented in this paper. The modified risk modeling method uses Monte Carlo simulations to model risk characteristics that can’t be determined without guess work and it was tested in vulnerability assessment activities on real production systems and in theory by assigning discrete uniform assumptions to all risk charac-teristics (risk attributes and evaluate the results after 1.5 million rounds of Monte Carlo simu-lations.

  13. Critical Quantitative Inquiry in Context

    Science.gov (United States)

    Stage, Frances K.; Wells, Ryan S.

    2014-01-01

    This chapter briefly traces the development of the concept of critical quantitative inquiry, provides an expanded conceptualization of the tasks of critical quantitative research, offers theoretical explanation and justification for critical research using quantitative methods, and previews the work of quantitative criticalists presented in this…

  14. Development and applications of quantitative NMR spectroscopy

    International Nuclear Information System (INIS)

    Yamazaki, Taichi

    2016-01-01

    Recently, quantitative NMR spectroscopy has attracted attention as an analytical method which can easily secure traceability to SI unit system, and discussions about its accuracy and inaccuracy are also started. This paper focuses on the literatures on the advancement of quantitative NMR spectroscopy reported between 2009 and 2016, and introduces both NMR measurement conditions and actual analysis cases in quantitative NMR. The quantitative NMR spectroscopy using an internal reference method enables accurate quantitative analysis with a quick and versatile way in general, and it is possible to obtain the precision sufficiently applicable to the evaluation of pure substances and standard solutions. Since the external reference method can easily prevent contamination to samples and the collection of samples, there are many reported cases related to the quantitative analysis of biologically related samples and highly scarce natural products in which NMR spectra are complicated. In the precision of quantitative NMR spectroscopy, the internal reference method is superior. As the quantitative NMR spectroscopy widely spreads, discussions are also progressing on how to utilize this analytical method as the official methods in various countries around the world. In Japan, this method is listed in the Pharmacopoeia and Japanese Standard of Food Additives, and it is also used as the official method for purity evaluation. In the future, this method will be expected to spread as the general-purpose analysis method that can ensure traceability to SI unit system. (A.O.)

  15. Facilitating arrhythmia simulation: the method of quantitative cellular automata modeling and parallel running

    Directory of Open Access Journals (Sweden)

    Mondry Adrian

    2004-08-01

    Full Text Available Abstract Background Many arrhythmias are triggered by abnormal electrical activity at the ionic channel and cell level, and then evolve spatio-temporally within the heart. To understand arrhythmias better and to diagnose them more precisely by their ECG waveforms, a whole-heart model is required to explore the association between the massively parallel activities at the channel/cell level and the integrative electrophysiological phenomena at organ level. Methods We have developed a method to build large-scale electrophysiological models by using extended cellular automata, and to run such models on a cluster of shared memory machines. We describe here the method, including the extension of a language-based cellular automaton to implement quantitative computing, the building of a whole-heart model with Visible Human Project data, the parallelization of the model on a cluster of shared memory computers with OpenMP and MPI hybrid programming, and a simulation algorithm that links cellular activity with the ECG. Results We demonstrate that electrical activities at channel, cell, and organ levels can be traced and captured conveniently in our extended cellular automaton system. Examples of some ECG waveforms simulated with a 2-D slice are given to support the ECG simulation algorithm. A performance evaluation of the 3-D model on a four-node cluster is also given. Conclusions Quantitative multicellular modeling with extended cellular automata is a highly efficient and widely applicable method to weave experimental data at different levels into computational models. This process can be used to investigate complex and collective biological activities that can be described neither by their governing differentiation equations nor by discrete parallel computation. Transparent cluster computing is a convenient and effective method to make time-consuming simulation feasible. Arrhythmias, as a typical case, can be effectively simulated with the methods

  16. PCR-free quantitative detection of genetically modified organism from raw materials – A novel electrochemiluminescence-based bio-barcode method

    Science.gov (United States)

    Zhu, Debin; Tang, Yabing; Xing, Da; Chen, Wei R.

    2018-01-01

    Bio-barcode assay based on oligonucleotide-modified gold nanoparticles (Au-NPs) provides a PCR-free method for quantitative detection of nucleic acid targets. However, the current bio-barcode assay requires lengthy experimental procedures including the preparation and release of barcode DNA probes from the target-nanoparticle complex, and immobilization and hybridization of the probes for quantification. Herein, we report a novel PCR-free electrochemiluminescence (ECL)-based bio-barcode assay for the quantitative detection of genetically modified organism (GMO) from raw materials. It consists of tris-(2’2’-bipyridyl) ruthenium (TBR)-labele barcode DNA, nucleic acid hybridization using Au-NPs and biotin-labeled probes, and selective capture of the hybridization complex by streptavidin-coated paramagnetic beads. The detection of target DNA is realized by direct measurement of ECL emission of TBR. It can quantitatively detect target nucleic acids with high speed and sensitivity. This method can be used to quantitatively detect GMO fragments from real GMO products. PMID:18386909

  17. A Quantitative Method to Screen Common Bean Plants for Resistance to Bean common mosaic necrosis virus.

    Science.gov (United States)

    Strausbaugh, C A; Myers, J R; Forster, R L; McClean, P E

    2003-11-01

    ABSTRACT A quantitative method to screen common bean (Phaseolus vulgaris) plants for resistance to Bean common mosaic necrosis virus (BCMNV) is described. Four parameters were assessed in developing the quantitative method: symptoms associated with systemic virus movement, plant vigor, virus titer, and plant dry weight. Based on these parameters, two rating systems (V and VV rating) were established. Plants from 21 recombinant inbred lines (RILs) from a Sierra (susceptible) x Olathe (partially resistant) cross inoculated with the BCMNV-NL-3 K strain were used to evaluate this quantitative approach. In all, 11 RILs exhibited very susceptible reactions and 10 RILs expressed partially resistant reactions, thus fitting a 1:1 susceptible/partially resistant ratio (chi(2) = 0.048, P = 0.827) and suggesting that the response is mediated by a single gene. Using the classical qualitative approach based only on symptom expression, the RILs were difficult to separate into phenotypic groups because of a continuum of responses. By plotting mean percent reduction in either V (based on visual symptoms) or VV (based on visual symptoms and vigor) rating versus enzyme-linked immunosorbent assay (ELISA) absorbance values, RILs could be separated clearly into different phenotypic groups. The utility of this quantitative approach also was evaluated on plants from 12 cultivars or pure lines inoculated with one of three strains of BCMNV. Using the mean VV rating and ELISA absorbance values, significant differences were established not only in cultivar and pure line comparisons but also in virus strain comparisons. This quantitative system should be particularly useful for the evaluation of the independent action of bc genes, the discovery of new genes associated with partial resistance, and assessing virulence of virus strains.

  18. A rigorous proof of the Landau-Peierls formula and much more

    DEFF Research Database (Denmark)

    Briet, Philippe; Cornean, Horia; Savoie, Baptiste

    2012-01-01

    We present a rigorous mathematical treatment of the zero-field orbital magnetic susceptibility of a non-interacting Bloch electron gas, at fixed temperature and density, for both metals and semiconductors/insulators. In particular, we obtain the Landau-Peierls formula in the low temperature and d...... and density limit as conjectured by Kjeldaas and Kohn (Phys Rev 105:806–813, 1957)....

  19. Development of method quantitative content of dihydroquercetin. Report 1

    Directory of Open Access Journals (Sweden)

    Олександр Юрійович Владимиров

    2016-01-01

    Full Text Available Today is markedly increasing scientific interest in the study of flavonoids in plant objects due to their high biological activity. In this regard, the urgent task of analytical chemistry is in developing available analytical techniques of determination for flavonoids in plant objects.Aim. The aim was to develop specific techniques of quantitative determination for dihydroquercetin and determination of its validation characteristics.Methods. The technique for photocolorimetric quantification of DQW, which was based on the specific reaction of cyanidine chloride formation when added zinc powder to dihydroquercetin solution in an acidic medium has been elaborated.Results. Photocolorimetric technique of determining flavonoids recalculating on DQW has been developed, its basic validation characteristics have been determined. The obtained metrological characteristics of photocolorimetric technique for determining DQW did not exceed admissibility criteria in accordance with the requirements of the State Pharmacopoeia of Ukraine.Conclusions. By the results of statistical analysis of experimental data, it has been stated that the developed technique can be used for quantification of DQW. Metrological data obtained indicate that the method reproduced in conditions of two different laboratories with confidence probability 95 % unit value deviation was 101,85±2,54 %

  20. A Targeted LC-MS/MS Method for the Simultaneous Detection and Quantitation of Egg, Milk, and Peanut Allergens in Sugar Cookies.

    Science.gov (United States)

    Boo, Chelsea C; Parker, Christine H; Jackson, Lauren S

    2018-01-01

    Food allergy is a growing public health concern, with many individuals reporting allergies to multiple food sources. Compliance with food labeling regulations and prevention of inadvertent cross-contact in manufacturing requires the use of reliable methods for the detection and quantitation of allergens in processed foods. In this work, a novel liquid chromatography-tandem mass spectrometry multiple-reaction monitoring method for multiallergen detection and quantitation of egg, milk, and peanut was developed and evaluated in an allergen-incurred baked sugar cookie matrix. A systematic evaluation of method parameters, including sample extraction, concentration, and digestion, were optimized for candidate allergen peptide markers. The optimized method enabled the reliable detection and quantitation of egg, milk, and peanut allergens in sugar cookies, with allergen concentrations as low as 5 ppm allergen-incurred ingredient.