  1. AUGMENTATION OF RIBS TURBULATORS HEIGHT ON THE HYDROTHERMAL PERFORMANCE OF DOUBLE PIPE HEAT EXCHANGER

    Directory of Open Access Journals (Sweden)

    HUSSAIN H. AL-KAYIEM

    2017-02-01

    Full Text Available Thermal performance of double pipe heat exchanger can be enhanced by imposed turbulence in the annular flow using artificial roughening. This paper presents experimental results on enhancing the heat transfer by artificial roughening using energy promoters installed on the inner surface of the cold flow annulus. An experimental test rig was fabricated having 2.0 m long annular flow test section with 76.2 mm and 34.2 mm outside and inside diameters, respectively. The energy promoters have ribs shape with rectangular cross section. Two cases of rib’s pitch to height ratios, equal to 10 and 15 and three height to hydraulic diameter, equal to 0.0595, 0.083, and 0.107 have been studied. The investigations were carried out at various flow rates within Reynolds number range of 2900 to 21000 in the cold annulus. For each roughening case, the thermal and hydraulic performances wereevaluated by determining Stanton number and the associated pressure drop, respectively. The experimental results showed that enhancement in the heat transfer was combined with a penalty in the pressure drop due to the increase in the friction factor values. The combined hydrothermal enhancement results of the DPHE, in terms of the performance index, indicate that the small height ribs to hydraulic diameter of 0.0595, augmented higher than the large height ribs to hydraulic diameter of 0.107. Hence, it is recommended to use ribs installed on the inner surface of the annulus ribs to hydraulic diameter in the range of 0.06 ± 0.005. Also, it is recommended to investigate further parameters to explore further on the influencing of the ribs on the hydrothermal performance of the DPHE.

  2. Effect of Aspect Ratio, Channel Orientation, Rib Pitch-to-Height Ratio, and Number of Ribbed Walls on Pressure Drop Characteristics in a Rotating Channel with Detached Ribs

    Directory of Open Access Journals (Sweden)

    K. Arun

    2007-01-01

    Full Text Available The present work involves experimental investigation of the effects of aspect ratio, channel orientation angle, rib pitch-to-height ratio (P/e, and number of ribbed walls on friction factor in orthogonally rotating channel with detached ribs. The ribs are separated from the base wall to provide a small region of flow between the base wall and the ribs. Experiments have been conducted at Reynolds number ranging from 10000–17000 with rotation numbers varying from 0–0.38. Pitch-to-rib height ratios (P/e of 5 and 10 at constant rib height-to-hydraulic diameter ratio (e/D of 0.1 and a clearance ratio (C/e of 0.38 are considered. The rib angle of attack with respect to mainstream flow is 90∘. The channel orientation at which the ribbed wall becomes trailing surface (pressure side on which the Coriolis force acts is considered as the 0∘ orientation angle. For one-wall ribbed case, channel is oriented from 0∘ to 180∘ about its axis in steps of 30∘ to change the orientation angle. For two-wall ribbed case, the orientation angle is changed from 0∘ to 90∘ in steps of 30∘. Friction factors for the detached ribbed channels are compared with the corresponding attached ribbed channel. It is found that in one-wall detached ribbed channel, increase in the friction factor ratio with the orientation angle is lower for rectangular channel compared to that of square channel for both the pitch-to-rib height ratios of 5 and 10 at a given Reynolds number and rotation number. Friction factor ratios of two-wall detached ribbed rectangular channel are comparable with corresponding two-wall detached ribbed square channel both under stationary and rotating conditions.

  3. Effect of Channel Orientation and Rib Pitch-to-Height Ratio on Pressure Drop in a Rotating Square Channel with Ribs on Two Opposite Surfaces

    Directory of Open Access Journals (Sweden)

    Prabhu S. V.

    2005-01-01

    Full Text Available The effect of channel orientation and rib pitch-to-height ratio on the pressure drop distribution in a rib-roughened channel is an important issue in turbine blade cooling. The present investigation is a study of the overall pressure drop distribution in a square cross-sectioned channel, with rib turbulators, rotating about an axis normal to the free stream. The ribs are configured in a symmetric arrangement on two opposite surfaces with a rib angle of 90 ∘ to the mainstream flow. The study has been conducted for three Reynolds numbers, namely, 13 000, 17 000, and 22 000 with the rotation number varying from 0– 0.38 . Experiments have been carried out for various rib pitch-to-height ratios ( P/e with a constant rib height-to-hydraulic diameter ratio ( e/D of 0.1 . The test section in which the ribs are placed on the leading and trailing surfaces is considered as the base case ( orientation angle= 0 ∘ , Coriolis force vector normal to the ribbed surfaces. The channel is turned about its axis in steps of 15 ∘ to vary the orientation angle from 0 ∘ to 90 ∘ . The overall pressure drop does not change considerably under conditions of rotation for the base case. However, for the other cases tested, it is observed that the overall pressure drop increases with an increase in the rotation number for a given orientation angle and also increases with an increase in the orientation angle for a given rotation number. This change is attributed to the variation in the separation zone downstream of the ribs due to the presence of the Coriolis force—local pressure drop data is presented which supports this idea. At an orientation angle of 90 ∘ (ribs on the top and bottom surfaces, Coriolis force vector normal to the smooth surfaces, the overall pressure drop is observed to be maximum during rotation. The overall pressure drop for a case with a rib pitch-to-height ratio of 5 on both surfaces is found to be the highest

  4. Optimizing rib width to height and rib spacing to deck plate thickness ratios in orthotropic decks

    Directory of Open Access Journals (Sweden)

    Abdullah Fettahoglu

    2016-12-01

    Full Text Available Orthotropic decks are composed of deck plate, ribs, and cross-beams and are frequently used in industry to span long distances, due to their light structures and load carrying capacities. Trapezoidal ribs are broadly preferred as longitudinal stiffeners in design of orthotropic decks. They supply the required stiffness to the orthotropic deck in traffic direction. Trapezoidal ribs are chosen in industrial applications because of their high torsional and buckling rigidity, less material and welding needs. Rib width, height, spacing, thickness of deck plate are important parameters for designing of orthotropic decks. In the scope of this study, rib width to height and rib spacing to deck plate thickness ratios are assessed by means of the stresses developed under different ratios of these parameters. For this purpose a FE-model of orthotropic bridge is generated, which encompasses the entire bridge geometry and conforms to recommendations given in Eurocode 3 Part 2. Afterwards necessary FE-analyses are performed to reveal the stresses developed under different rib width to height and rib spacing to deck plate thickness ratios. Based on the results obtained in this study, recommendations regarding these ratios are provided for orthotropic steel decks occupying trapezoidal ribs.

  5. Numerical Study of the Rib Arrangements for Enhancing Heat Transfer in a Two-pass Channel of Large Aspect Ratio

    Energy Technology Data Exchange (ETDEWEB)

    Han, Sol; Choi, Seok Min; Sohn, Ho-Seong; Cho, Hyung Hee [Yonsei Univ., Seoul (Korea, Republic of)

    2017-03-15

    The present study investigated the effect of the rib arrangement and a guide vane for enhancing internal cooling of the blade. Two types of rib arrangements were used in the first and second passage in parallel. Aspect ratio of the channel was 5 and a fixed Reynolds number based on hydraulic diameter was 10,000. The attack angle of rib was 60°, rib pitch-to-height ratio (p/e) was 10, and the rib height-to-hydraulic-diameter ratio (e/D{sub n}) was 0.075. The effect of an interaction between Dean vortices and the secondary vortices from the first passage was observed. Overall, the attack angle of rib in the first passage was dominant factor to heat transfer and flow patterns in turning region. Also, the channel with a guide vane showed enhanced heat transfer at the tip surface with reducing flow separation and recirculation.

  6. RIBBED DOUBLE PIPE HEAT EXCHANGER: ANALYTICAL ANALYSIS

    Directory of Open Access Journals (Sweden)

    HUSSAIN H. AL-KAYIEM

    2011-02-01

    Full Text Available This paper presents the findings obtained by modeling a Double Pipe Heat Exchanger (DPHE equipped with repeated ribs from the inside for artificial roughing. An analytical procedure was developed to analyze the thermal and hydraulic performance of the DPHE with and without ribbing. The procedure was verified by comparing with experimental reported results and they are in good agreement. Several parameters were investigated in this study including the effect of ribs pitch to height ratios, P/e= 5, 10, 15, and 20, and ribs to hydraulic diameter ratios, e/Dh= 0.0595, 0.0765, and 0.107. These parameters were studied at various operating Reynolds number ranging from 2500 to 150000. Different installation configurations were investigated, too. An enhan-cement of 4 times in the heat transfer in terms of Stanton number was achieved at the expense of 38 times increase of pressure drop across the flow in terms of friction facto values.

  7. Numerical Simulation of Turbulent Fluid Flow and Heat Transfer in a Ribbed Rotating Two-Pass Square Duct

    Directory of Open Access Journals (Sweden)

    Liou Tong-Miin

    2005-01-01

    Full Text Available The local turbulent fluid flow and heat transfer in a rotating two-pass square duct with 19 pairs of in-line 90 ∘ ribs have been investigated computationally. A Reynolds-averaged Navier-Stokes equation (RANS with a two-layer k − ϵ turbulence model was solved. The in-line 90 ∘ ribs were arranged on the leading and trailing walls with rib height-to-hydraulic diameter ratio and pitch-to-height ratio of 0.136 and 10, respectively. The Reynolds number, based on duct hydraulic diameter and bulk mean velocity, was fixed at 1.0 × 10 4 whereas the rotational number varied from 0 to 0.2 . Results are validated with previous measured velocity field and heat transfer coefficient distributions. The validation shows that the effect of rotation on the passage-averaged Nusselt number ratio can be predicted reasonably well; nevertheless, the transverse mean velocity and, in turn, the distribution of regional-averaged Nusselt number ratio are markedly underpredicted in the regions toward which the Coriolis force is directed. Further CFD studies are needed.

  8. Forced convection heat transfer of steam in a square ribbed channel

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jiazeng; Gao, Jianmin; Gao, Tieyu [Xi' an Jiaotong University, Shaanxi (China)

    2012-04-15

    An experimental study of heat transfer characteristics of steam in a square channel (simulating a gas turbine blade cooling passage) with two opposite surfaces roughened by 60 deg parallel ribs was performed. The ranges of key governing parameters were: Reynolds numbers (Re) based on the channel hydraulic diameter (30000-140000), entry gauge pressure (0.2Mpa-0.5Mpa), heat flux of heat transfer surface area (5kWm{sup -2}-20kWm{sup -2}), and steam superheat (13 .deg. C-51 .deg. C). The test channel length was 1000mm, while the rib spacing (p/e) was 10, and the ratio of rib height (e) to hydraulic diameter (D) was 0.048. The test channel was heated by passing current through stainless steel walls instrumented with thermocouples. The local heat transfer coefficients on the ribbed wall from the channel entrance to the fully developed regions were measured. The semi-empirical correlation was fitted out by using the average Nusselt numbers in the fully developed region to cover the range of Reynolds number. The correlation can be used in the design of new generation of gas turbine blade cooled by steam.

  9. CFD Analysis on the Thermal Hydraulic Performance of an SAH Duct with Multi V-Shape Roughened Ribs

    Directory of Open Access Journals (Sweden)

    Anil Kumar

    2016-05-01

    Full Text Available This study presents the heat transfer and fluid flow characteristics in a rib-roughened SAH (solar air heater channel. The artificial roughness of the rectangular channel was in the form of a thin circular wire in discrete multi V-pattern rib geometries. The effect of this geometry on heat transfer, fluid flow, and performance augmentation was investigated using the CFD (computational fluid dynamics. The roughness parameters were a relative discrete distance of 0.69, a relative rib height of 0.043, a relative rib pitch of 10, a relative rib width of 6.0, and a flow-attack-angle of 60°. The discrete width ratios and Reynolds numbers ranged from 0.5 to 2.0 and from 2000 to 20,000, respectively. The CFD results using the renormalization k-epsilon model were in good agreement with the empirical relationship. This model was used to investigate the heat transfer and fluid flow characteristics in the multi V-pattern rib roughened SAH channel. The thermo-hydraulic performance was found to be the best for the discrete width ratio of 1.0. A discrete multi V-pattern rib combined with dimple staggered ribs also had better overall thermal performance compared to other rib shapes.

  10. Heat transfer performance comparison of steam and air in gas turbine cooling channels with different rib angles

    Science.gov (United States)

    Shi, Xiaojun; Gao, Jianmin; Xu, Liang; Li, Fajin

    2013-11-01

    Using steam as working fluid to replace compressed air is a promising cooling technology for internal cooling passages of blades and vanes. The local heat transfer characteristics and the thermal performance of steam flow in wide aspect ratio channels ( W/ H = 2) with different angled ribs on two opposite walls have been experimentally investigated in this paper. The averaged Nusselt number ratios and the friction factor ratios of steam and air in four ribbed channels were also measured under the same test conditions for comparison. The Reynolds number range is 6,000-70,000. The rib angles are 90°, 60°, 45°, and 30°, respectively. The rib height to hydraulic diameter ratio is 0.047. The pitch-to-rib height ratio is 10. The results show that the Nusselt number ratios of steam are 1.19-1.32 times greater than those of air over the range of Reynolds numbers studied. For wide aspect ratio channels using steam as the coolant, the 60° angled ribs has the best heat transfer performance and is recommended for cooling design.

  11. Comparative Study of Convective Heat Transfer Performance of Steam and Air Flow in Rib Roughened Channels

    Science.gov (United States)

    Ma, Chao; Ji, Yongbin; Ge, Bing; Zang, Shusheng; Chen, Hua

    2018-04-01

    A comparative experimental study of heat transfer characteristics of steam and air flow in rectangular channels roughened with parallel ribs was conducted by using an infrared camera. Effects of Reynolds numbers and rib angles on the steam and air convective heat transfer have been obtained and compared with each other for the Reynolds number from about 4,000 to 15,000. For all the ribbed channels the rib pitch to height ratio (p/e) is 10, and the rib height to the channel hydraulic diameter ratio is 0.078, while the rib angles are varied from 90° to 45°. Based on experimental results, it can be found that, even though the heat transfer distributions of steam and air flow in the ribbed channels are similar to each other, the steam flow can obtain higher convective heat transfer enhancement capability, and the heat transfer enhancement of both the steam and air becomes greater with the rib angle deceasing from 90° to 45°. At Reynolds number of about 12,000, the area-averaged Nusselt numbers of the steam flow is about 13.9%, 14.2%, 19.9% and 23.9% higher than those of the air flow for the rib angles of 90°, 75°, 60° and 45° respectively. With the experimental results the correlations for Nusselt number in terms of Reynolds number and rib angle for the steam and air flow in the ribbed channels were developed respectively.

  12. Computational Investigations in Rectangular Convergent and Divergent Ribbed Channels

    Science.gov (United States)

    Sivakumar, Karthikeyan; Kulasekharan, N.; Natarajan, E.

    2018-05-01

    Computational investigations on the rib turbulated flow inside a convergent and divergent rectangular channel with square ribs of different rib heights and different Reynolds numbers (Re=20,000, 40,000 and 60,000). The ribs were arranged in a staggered fashion between the upper and lower surfaces of the test section. Computational investigations are carried out using computational fluid dynamic software ANSYS Fluent 14.0. Suitable solver settings like turbulence models were identified from the literature and the boundary conditions for the simulations on a solution of independent grid. Computations were carried out for both convergent and divergent channels with 0 (smooth duct), 1.5, 3, 6, 9 and 12 mm rib heights, to identify the ribbed channel with optimal performance, assessed using a thermo hydraulic performance parameter. The convergent and divergent rectangular channels show higher Nu values than the standard correlation values.

  13. A comparison of hydraulic architecture in three similarly sized woody species differing in their maximum potential height

    Science.gov (United States)

    Katherine A. McCulloh; Daniel M. Johnson; Joshua Petitmermet; Brandon McNellis; Frederick C. Meinzer; Barbara Lachenbruch; Nathan Phillips

    2015-01-01

    The physiological mechanisms underlying the short maximum height of shrubs are not understood. One possible explanation is that differences in the hydraulic architecture of shrubs compared with co-occurring taller trees prevent the shrubs from growing taller. To explore this hypothesis, we examined various hydraulic parameters, including vessel lumen diameter,...

  14. Tree diameter at breast height in relation to stump diameter by species group

    Science.gov (United States)

    Arthur G. Horn; Richard C. Keller

    1957-01-01

    A stump tally is one method of determining the volume of timber previously removed from an area in a logging operation. To estimate volume of standing timber from stumps, foresters must first know the relationship between stump diameters and tree diameters at breast height (d.b.h.).

  15. Using Four-Layer Sculpted Rib Cartilage Framework to Increase Transverse Height of the Reconstructive Ear in One Operative Stage for Microtia Patients.

    Science.gov (United States)

    Wan, Rui; Pang, Xingyuan; Ren, Jun

    2018-02-01

    This case study improves an operative method of ear reconstruction for microtia patients by using a four-layer rib cartilage framework to increase transverse height of the reconstructive ear to a natural level in one operative stage. The procedures of ear reconstruction were conducted from February 2014 to May 2016. The ear framework used in the procedures was fabricated from autologous rib cartilage into a four-layer spliced sculpture. Totally 23 patients with unilateral microtia were willing to be enrolled in this study. After the operation, 23 patients achieved 2.3-2.8 cm transverse height of reconstructed ears, which was basically the same as the normal side. Both patients and their families felt satisfied with the results. Follow-up was performed at 6-16 months after the procedures. Only one case showed significantly lowered transverse height of the reconstructed ear, compared to the normal one. It was due to the sleeping position of the patient (10-year-old boy), which put the reconstructed ear under pressure and reduced the transverse height of the ear. The method of four-layer sculpted autologous rib cartilage ear reconstruction has good clinical effect. It can provide a reconstructed ear that reaches normal transverse height and avoids a third operation to increase the transverse height by rib cartilage transplantation. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  16. Sugar maple height-diameter and age-diameter relationships in an uneven-aged northern hardwood stand

    Science.gov (United States)

    Laura S. Kenefic; R.D. Nyland

    1999-01-01

    Sugar maple (Acer saccharum Marsh.) height-diameter and age-diameter relationships are explored in a balanced uneven-aged northern hardwood stand in central New York. Results show that although both height and age vary considerably with diameter, these relationships can be described by statistically valid equations. The age-diameter relationship...

  17. Relationships between diameter and height of trees in natural ...

    African Journals Online (AJOL)

    Relationships between diameter and height of trees in natural tropical forest in Tanzania. Wilson A Mugasha, Ole M Bollandsås, Tron Eid. Abstract. The relationship between tree height (h) and tree diameter at breast height (dbh) is an important element describing forest stands. In addition, h often is a required variable in ...

  18. Generalized height-diameter models for Populus tremula L. stands

    African Journals Online (AJOL)

    USER

    2010-07-12

    Jul 12, 2010 ... and stand density) into the base height-diameter models increased the accuracy of prediction for P. tremula. .... parameter estimates compared with those obtained with ... using coefficient of determination for non-linear regression (. 2. R ), ..... stochastic height-diameter model for maritime pine ecoregions in.

  19. Sand transport in a two pass internal cooling duct with rib turbulators

    International Nuclear Information System (INIS)

    Singh, Sukhjinder; Tafti, Danesh; Reagle, Colin; Delimont, Jacob; Ng, Wing; Ekkad, Srinath

    2014-01-01

    Highlights: • Highest particle impingement observed in the bend and first quarter of 2nd pass. • Average particle impingement per pitch is 28% higher in the second pass. • Rib faces are by far the most susceptible to particle impingement. • Particle impingement is sensitive to particle size. • Particle impingement is sensitive to wall collision model used. - Abstract: Jet engines often operate under dirty conditions where large amounts of particulate matter can be ingested, especially, sand, ash and dirt. Particulate matter in different engine components can lead to degradation in performance. The focus of this study is to investigate the sand transport and deposition in the internal cooling passages of turbine blades. A two pass stationary square duct with rib turbulators subjected to sand ingestion is studied using Large Eddy Simulations (LES). Each pass has ribs on two opposite walls and aligned normal to the main flow direction. The rib pitch to rib height (P/e) is 9.28, the rib height to channel hydraulic diameter (e/D h ) is 0.0625 and calculations have been carried out for a bulk Reynolds number of 25,000. Particle sizes in the range 0.5–25 μm are considered, with the same size distribution as found in Arizona Road Dust (medium). Large Eddy Simulation (LES) with a wall-model is used to model the flow and sand particles are modeled using a discrete Lagrangian framework. Results quantify the distribution of particle impingement density on all surfaces. Highest particle impingement density is found in the first quarter section of the second pass after the 180° turn, where the recorded impingement is more than twice that of any other region. It is also found that the average particle impingement per pitch is 28% higher in the second pass than the first pass. Results show lower particle tendency to impact the region immediately behind the rib in the first pass compared to the second pass where particle impingement is more uniform in the region

  20. Contrastive experimental study on heat transfer and friction characteristics in steam cooled and air cooled rectangular channels with rib turbulators

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Jianying; Li, Guojun; Gao, Tieyu [Xian Jiaotong University, Xian (China)

    2014-09-15

    The present experiment compares the heat transfer and friction characteristics in steam cooled and air cooled rectangular channels (simulating a gas turbine blade cooling passage) with two opposite rib-roughened walls. The Reynolds number (Re) whose length scale is the hydraulic diameter of the passage is set within the range of 10000-60000. The channel length is 1000 mm. The pitch-to-rib height ratio, the channel aspect ratio and the channel blockage ratio is 10, 0.5 and 0.047, respectively. It is found that the average Nu, the average friction coefficient, and the heat transfer performance of both steam and air in the ribbed channels show almost the same change trend with the increase of Re. Under the same test conditions, the average Nu of steam is 30.2% higher than that of air, the average friction coefficient is 18.4% higher, and the heat transfer performances of steam on the ribbed and the smooth walls are 8.4% and 7.3% higher than those of air, respectively. In addition, semi-empirical correlations for the two test channels are developed, which can predict the Nu under the given test condition. The correlations can be used in the design of the internal cooling passage of new generation steam cooled gas turbine blade/vane.

  1. Experimental study on heat transfer augmentation for high heat flux removal in rib-roughened narrow channels

    Energy Technology Data Exchange (ETDEWEB)

    Islam, M.S.; Monde, Masanori [Saga Univ. (Japan); Hino, Ryutaro; Haga, Katsuhiro; Sudo, Yukio

    1997-07-01

    Frictional pressure drop and heat transfer performance in a very narrow rectangular channel having one-sided constant heat flux and repeated-ribs for turbulent flow have been investigated experimentally, and their experimental correlations were obtained using the least square method. The rib pitch-to-height ratios(p/k) were 10 and 20 while holding the rib height constant at 0.2mm, the Reynolds number(Re) from 2,414 to 98,458 under different channel heights of 1.2mm, 2.97mm, and 3.24mm, the rib height-to-channel equivalent diameter(k/De) of 0.03, 0.04, and 0.09 respectively. The results show that the rib-roughened surface augments heat transfer 2-3 times higher than that of the smooth surface with the expense of 2.8-4 times higher frictional pressure drop under Re=5000-10{sup 5}, p/k=10, and H=1.2mm. Experimental results obtained by channel height, H=1.2mm shows a little bit higher heat transfer and friction factor performance than the higher channel height, H=3.24mm. The effect of fin and consequently higher turbulence intensity are responsible for producing higher heat transfer rates. The obtained correlations could be used to design the cooling passages between the target plates to remove high heat flux up to 12MW/m{sup 2} generated at target plates in a high-intensity proton accelerator system. (author). 54 refs.

  2. Experimental study on heat transfer augmentation for high heat flux removal in rib-roughened narrow channels

    International Nuclear Information System (INIS)

    Islam, M.S.; Monde, Masanori; Hino, Ryutaro; Haga, Katsuhiro; Sudo, Yukio.

    1997-07-01

    Frictional pressure drop and heat transfer performance in a very narrow rectangular channel having one-sided constant heat flux and repeated-ribs for turbulent flow have been investigated experimentally, and their experimental correlations were obtained using the least square method. The rib pitch-to-height ratios(p/k) were 10 and 20 while holding the rib height constant at 0.2mm, the Reynolds number(Re) from 2,414 to 98,458 under different channel heights of 1.2mm, 2.97mm, and 3.24mm, the rib height-to-channel equivalent diameter(k/De) of 0.03, 0.04, and 0.09 respectively. The results show that the rib-roughened surface augments heat transfer 2-3 times higher than that of the smooth surface with the expense of 2.8-4 times higher frictional pressure drop under Re=5000-10 5 , p/k=10, and H=1.2mm. Experimental results obtained by channel height, H=1.2mm shows a little bit higher heat transfer and friction factor performance than the higher channel height, H=3.24mm. The effect of fin and consequently higher turbulence intensity are responsible for producing higher heat transfer rates. The obtained correlations could be used to design the cooling passages between the target plates to remove high heat flux up to 12MW/m 2 generated at target plates in a high-intensity proton accelerator system. (author). 54 refs

  3. Tree height-diameter allometry across the United States.

    Science.gov (United States)

    Hulshof, Catherine M; Swenson, Nathan G; Weiser, Michael D

    2015-03-01

    The relationship between tree height and diameter is fundamental in determining community and ecosystem structure as well as estimates of biomass and carbon storage. Yet our understanding of how tree allometry relates to climate and whole organismal function is limited. We used the Forest Inventory and Analysis National Program database to determine height-diameter allometries of 2,976,937 individuals of 293 tree species across the United States. The shape of the allometric relationship was determined by comparing linear and nonlinear functional forms. Mixed-effects models were used to test for allometric differences due to climate and floristic (between angiosperms and gymnosperms) and functional groups (leaf habit and shade tolerance). Tree allometry significantly differed across the United States largely because of climate. Temperature, and to some extent precipitation, in part explained tree allometric variation. The magnitude of allometric variation due to climate, however, had a phylogenetic signal. Specifically, angiosperm allometry was more sensitive to differences in temperature compared to gymnosperms. Most notably, angiosperm height was more negatively influenced by increasing temperature variability, whereas gymnosperm height was negatively influenced by decreasing precipitation and increasing altitude. There was little evidence to suggest that shade tolerance influenced tree allometry except for very shade-intolerant trees which were taller for any given diameter. Tree allometry is plastic rather than fixed and scaling parameters vary around predicted central tendencies. This allometric variation provides insight into life-history strategies, phylogenetic history, and environmental limitations at biogeographical scales.

  4. Dominant height-based height-diameter equations for trees in southern Indiana

    Science.gov (United States)

    John A., Jr. Kershaw; Robert C. Morrissey; Douglass F. Jacobs; John R. Seifert; James B. McCarter

    2008-01-01

    Height-diameter equations are developed based on dominant tree data collected in 1986 in 8- to 17-year-old clearcuts and the phase 2 Forest Inventory and Analysis plots on the Hoosier National Forest in south central Indiana. Two equation forms are explored: the basic, three-parameter Chapman-Richards function, and a modification of the three-parameter equation...

  5. Height-diameter allometry of tropical forest trees

    Science.gov (United States)

    T.R. Feldpausch; L. Banin; O.L. Phillips; T.R. Baker; S.L. Lewis; C.A. Quesada; K. Affum-Baffoe; E.J.M.M. Arets; N.J. Berry; M. Bird; E.S. Brondizio; P de Camargo; J. Chave; G. Djagbletey; T.F. Domingues; M. Drescher; P.M. Fearnside; M.B. Franca; N.M. Fyllas; G. Lopez-Gonzalez; A. Hladik; N. Higuchi; M.O. Hunter; Y. Iida; K.A. Salim; A.R. Kassim; M. Keller; J. Kemp; D.A. King; J.C. Lovett; B.S. Marimon; B.H. Marimon-Junior; E. Lenza; A.R. Marshall; D.J. Metcalfe; E.T.A. Mitchard; E.F. Moran; B.W. Nelson; R. Nilus; E.M. Nogueira; M. Palace; S. Patiño; K.S.-H. Peh; M.T. Raventos; J.M. Reitsma; G. Saiz; F. Schrodt; B. Sonke; H.E. Taedoumg; S. Tan; L. White; H. Woll; J. Lloyd

    2011-01-01

    Tropical tree height-diameter (H:D) relationships may vary by forest type and region making large-scale estimates of above-ground biomass subject to bias if they ignore these differences in stem allometry. We have therefore developed a new global tropical forest database consisting of 39 955 concurrent H and D measurements encompassing 283 sites in 22 tropical...

  6. Height-Diameter Equations for 12 Upland Species in the Missouri Ozark Highlands

    Science.gov (United States)

    J.R. Lootens; David R. Larsen; Stephen R. Shifley

    2007-01-01

    We calibrated a model predicting total tree height as a function of tree diameter for nine tree species common to the Missouri Ozarks. Model coefficients were derived from nearly 10,000 observed trees. The calibrated model did a good job predicting the mean height-diameter trend for each species (pseudo-R2 values ranged from 0.56 to 0.88), but...

  7. Tradeoffs between hydraulic and mechanical stress responses of mature Norway spruce trunk wood.

    Science.gov (United States)

    Rosner, Sabine; Klein, Andrea; Müller, Ulrich; Karlsson, Bo

    2008-08-01

    We tested the effects of growth characteristics and basic density on hydraulic and mechanical properties of mature Norway spruce (Picea abies (L.) Karst.) wood from six 24-year-old clones, grown on two sites in southern Sweden differing in water availability. Hydraulic parameters assessed were specific hydraulic conductivity at full saturation (ks100) and vulnerability to cavitation (Psi50), mechanical parameters included bending strength (sigma b), modulus of elasticity (MOE), compression strength (sigma a) and Young's modulus (E). Basic density, diameter at breast height, tree height, and hydraulic and mechanical parameters varied considerably among clones. Clonal means of hydraulic and mechanical properties were strongly related to basic density and to growth parameters across sites, especially to diameter at breast height. Compared with stem wood of slower growing clones, stem wood of rapidly growing clones had significantly lower basic density, lower sigma b, MOE, sigma a and E, was more vulnerable to cavitation, but had higher ks100. Basic density was negatively correlated to Psi50 and ks100. We therefore found a tradeoff between Psi50 and ks100. Clones with high basic density had significantly lower hydraulic vulnerability, but also lower hydraulic conductivity at full saturation and thus less rapid growth than clones with low basic density. This tradeoff involved a negative relationship between Psi50 and sigma b as well as MOE, and between ks100 and sigma b, MOE and sigma a. Basic density and Psi50 showed no site-specific differences, but tree height, diameter at breast height, ks100 and mechanical strength and stiffness were significantly lower at the drier site. Basic density had no influence on the site-dependent differences in hydraulic and mechanical properties, but was strongly negatively related to diameter at breast height. Selecting for growth may thus lead not only to a reduction in mechanical strength and stiffness but also to a reduction in

  8. Height-Diameter Models for Mixed-Species Forests Consisting of Spruce, Fir, and Beech

    Directory of Open Access Journals (Sweden)

    Petráš Rudolf

    2014-06-01

    Full Text Available Height-diameter models define the general relationship between the tree height and diameter at each growth stage of the forest stand. This paper presents generalized height-diameter models for mixed-species forest stands consisting of Norway spruce (Picea abies Karst., Silver fir (Abies alba L., and European beech (Fagus sylvatica L. from Slovakia. The models were derived using two growth functions from the exponential family: the two-parameter Michailoff and three-parameter Korf functions. Generalized height-diameter functions must normally be constrained to pass through the mean stand diameter and height, and then the final growth model has only one or two parameters to be estimated. These “free” parameters are then expressed over the quadratic mean diameter, height and stand age and the final mathematical form of the model is obtained. The study material included 50 long-term experimental plots located in the Western Carpathians. The plots were established 40-50 years ago and have been repeatedly measured at 5 to 10-year intervals. The dataset includes 7,950 height measurements of spruce, 21,661 of fir and 5,794 of beech. As many as 9 regression models were derived for each species. Although the “goodness of fit” of all models showed that they were generally well suited for the data, the best results were obtained for silver fir. The coefficient of determination ranged from 0.946 to 0.948, RMSE (m was in the interval 1.94-1.97 and the bias (m was -0.031 to 0.063. Although slightly imprecise parameter estimation was established for spruce, the estimations of the regression parameters obtained for beech were quite less precise. The coefficient of determination for beech was 0.854-0.860, RMSE (m 2.67-2.72, and the bias (m ranged from -0.144 to -0.056. The majority of models using Korf’s formula produced slightly better estimations than Michailoff’s, and it proved immaterial which estimated parameter was fixed and which parameters

  9. PIV Measurements of Turbulent Flow in a Channel with Solid or Perforated Ribs

    DEFF Research Database (Denmark)

    Wang, Lei; Salewski, Mirko; Sundén, Bengt

    2011-01-01

    Particle image velocimetry measurements are performed in a channel with periodic ribs on one wall. We investigate the flow around two different rib configurations: solid and perforated ribs with a slit. The ribs obstruct the channel by 20% of its height and are arranged 10 rib heights apart. For ...

  10. Benefits of Two Turbine Rotor Diameters and Hub Heights in the Same Wind Farm

    Energy Technology Data Exchange (ETDEWEB)

    Dykes, Katherine L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Stanley, Andrew P. J. [Brigham Young University; Ning, Andrew [Brigham Young University

    2018-01-12

    Significant turbine-wake interactions greatly reduce power output in a wind farm. If different turbine hub heights and rotor diameters are included in the same wind farm, the wake interference in the farm will be reduced, resulting in a lower cost of energy (COE) than a farm with identical turbines. In this paper, we present a method to model wind farm COE in farms with hub heights and rotor diameters that vary across the wind farm. We also demonstrate how to optimize these wind farms to minimize COE. The results show that COE can be greatly reduced in wind farms with non-homogeneous turbines, especially when the turbines are spaced close together. For a unidirectional wind rose, including different turbine design in the wind farm has a similar decrease in COE to spreading the wind turbines farther apart. When the rotor diameter and hub height of the wind turbines in a farm are optimized uniformly, a COE decrease of 4% to 13% (depending on the grid spacing and wind shear exponent) is achieved compared to the baseline. When the rotor diameter and turbine heights are optimized non-uniformly, with two different diameters and heights throughout the farm, there is a COE decrease of 22% to 41% compared to the baseline. For a more spread wind rose with a dominant probability from the west, there is a COE decrease between 3% and 10% for uniformly optimized rotor diameter and height compared to the baseline. With two optimized rotor diameters and heights through the farm, a COE decrease of 3% to 19% is achieved. For a similar wind rose shifted such that the dominant wind direction is from the northwest, a COE decrease between 3% and 10% results from uniformly optimized wind turbines compared to the baseline. A COE decrease of 3% to 17% compared to the baseline occurs with two different turbines are optimized throughout the wind farm.

  11. Modeling Caribbean tree stem diameters from tree height and crown width measurements

    Science.gov (United States)

    Thomas Brandeis; KaDonna Randolph; Mike Strub

    2009-01-01

    Regression models to predict diameter at breast height (DBH) as a function of tree height and maximum crown radius were developed for Caribbean forests based on data collected by the U.S. Forest Service in the Commonwealth of Puerto Rico and Territory of the U.S. Virgin Islands. The model predicting DBH from tree height fit reasonably well (R2 = 0.7110), with...

  12. Heat transfer augmentation for high heat flux removal in rib-roughened narrow channels

    International Nuclear Information System (INIS)

    Islam, M.S.; Hino, Ryutaro; Haga, Katsuhiro; Sudo, Yukio; Monde, Masanori.

    1997-03-01

    Heat transfer augmentation in narrow rectangular channels in a target system is a very important method to remove high heat flux up to 12 MW/m 2 generated at target plates of a high-intensity proton accelerator of 1.5 GeV and 1 mA with a proton beam power of 1.5 MW. In this report, heat transfer coefficients and friction factors in narrow rectangular channels with one-sided rib-roughened surface were evaluated for fully developed flows in the range of the Reynolds number from 6,000 to 1,00,000; the rib pitch-to-height ratios (p/k) were 10,20 and 30; the rib height-to-equivalent diameter ratios (k/De) were 0.025, 0.03 and 0.1 by means of previous existing experimental correlations. The rib-roughened surface augmented heat transfer coefficients approximately 4 times higher than the smooth surface at Re=10,000, p/k=10 and k/De=0.1; friction factors increase around 22 times higher. In this case, higher heat flux up to 12 MW/m 2 could be removed from the rib-roughened surface without flow boiling which induces flow instability; but pressure drop reaches about 1.8 MPa. Correlations obtained by air-flow experiments have showed lower heat transfer performance with the water-flow conditions. The experimental apparatus was proposed for further investigation on heat transfer augmentation in very narrow channels under water-flow conditions. This report presents the evaluation results and an outline of the test apparatus. (author)

  13. Flow and heat transfer in parallel channel attached with equally-spaced ribs, 2

    International Nuclear Information System (INIS)

    Kunugi, Tomoaki; Takizuka, Takakazu

    1980-09-01

    Using a computer code for the analysis of the flow and heat transfer in a parallel channel attached with equally-spaced ribs, calculations are performed when a pitch to rib-width ratio is 7 : 1, a rib-width to rib-height ratio is 2 : 1 and a channel-height to rib-height is 3 : 1. Assuming that the fluid properties and the heat-flux at the wall of this channel are constant, characteristics of the flow and heat transfer are analyzed in the range of Reynolds number from 10 to 250. The following results are obtained: (1) The separation region behind a rib grows downstream with the increase of Reynolds number. (2) The pressure drop of ribbed channel is greater than that of the smooth channel, and increases as Reynolds number increases. (3) The mean Nusselt number of ribbed channel is about 10 - 11 at the upper wall and about 7.5 at the lower wall in the range of Reynolds number from 10 to 250. (author)

  14. Equations for predicting diameter, height, crown width, and leaf area of San Joaquin Valley street trees

    Science.gov (United States)

    P.J. Peper; E.G. McPherson; S.M. Mori

    2001-01-01

    Although the modeling of energy-use reduction, air pollution uptake, rainfall interception, and microclimate modification associated with urban trees depends on data relating diameter at breast height (dbh) , crown height, crown diameter, and leaf area to tree age or dbh, scant information is available for common municipal tree species . I n this study , tree height ,...

  15. A Study on the Performance of the Split Reaction Water Turbine with Guide Ribs

    Science.gov (United States)

    Allen, Deuel H.; Villanueva, Eliseo P.

    2015-09-01

    The development of technologies that make use of renewable energy is of great significance presently. A new kind of turbine called Split Reaction Water Turbine (SRWT) using PVC pipes as material is a major contribution towards harnessing the energy potentials of small stream low head water resources. SRWTs of diameter to height ratio (D/H = 110 cm/160 cm) were tested at the MSU-IIT College of Engineering Fluid Engineering Laboratory. Data on volumetric flow and pressure head at the turbine inlet of the SRWT were recorded using National Instrument Data Processing System using LabView software. In later experiments, guide ribs were installed at the vane of the exit nozzles in order to determine the difference in the performance of the ribbed and the non-ribbed SRWT. Simulations of the running SRWT were conducted using SOLIDWORKS software. Results of the simulations aided in the thorough analyses of the data from the experimental runs. A comparison of data from the ribbed and non-ribbed SRWT shows that guide ribs were effective in directing the momentum of the exiting water to improve the speed of rotation. In this study, the increase in the speed of the Split Reaction Water Turbine was as much as 46%.

  16. Conditions of rib design for polycarbonate resin with high glossy surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Seong Won [Seoul National University of Science and Technology, Seoul (Korea, Republic of)

    2013-10-15

    Much attention has been being given to the importance of product surfaces in the field of plastic parts, as industrial design has become one of the key elements of product success. These plastic parts incorporate rib-like geometries on the non-appearance surfaces of plastic in order to increase the stiffness of rigidity of the section, but they often cause appearance problems of the product's surface overall by making a sink mark on that surface. The thickness, height and draft-angle of the rib are generally known as major parameters influencing the sink mark on the appearance surface. Therefore, designers of plastic parts must determine the variables of reinforcing ribs. The goal of this study is to find the optimum design variables in the mixing conditions of the thickness, the height and the draft angle of reinforcing ribs so that designers of plastic parts can easily determine the conditions of the reinforcing ribs as the part's section thickness varies within an objective limit in polycarbonate plastic resin and a high glossy surface that are widely applied in the creation of plastic products. We investigated the actual depths of sink marks on the surface of a specimen that was manufactured with an injection mold specifically for this study. Response surface methodology with the Box-Behnken design was used to analyze the regression curve of real depths with combinations of the thickness, height and draft angle of the ribs. The result shows that the most influential factor to increase the shrinkage is the thickness of ribs and that the optimum value of the rib thickness is a range from multiple of 0.25 to 0.34 of the section thickness. Also, the rib height and rib draft angle are not major factors that can change the sink amount.

  17. Conditions of rib design for polycarbonate resin with high glossy surfaces

    International Nuclear Information System (INIS)

    Jeong, Seong Won

    2013-01-01

    Much attention has been being given to the importance of product surfaces in the field of plastic parts, as industrial design has become one of the key elements of product success. These plastic parts incorporate rib-like geometries on the non-appearance surfaces of plastic in order to increase the stiffness of rigidity of the section, but they often cause appearance problems of the product's surface overall by making a sink mark on that surface. The thickness, height and draft-angle of the rib are generally known as major parameters influencing the sink mark on the appearance surface. Therefore, designers of plastic parts must determine the variables of reinforcing ribs. The goal of this study is to find the optimum design variables in the mixing conditions of the thickness, the height and the draft angle of reinforcing ribs so that designers of plastic parts can easily determine the conditions of the reinforcing ribs as the part's section thickness varies within an objective limit in polycarbonate plastic resin and a high glossy surface that are widely applied in the creation of plastic products. We investigated the actual depths of sink marks on the surface of a specimen that was manufactured with an injection mold specifically for this study. Response surface methodology with the Box-Behnken design was used to analyze the regression curve of real depths with combinations of the thickness, height and draft angle of the ribs. The result shows that the most influential factor to increase the shrinkage is the thickness of ribs and that the optimum value of the rib thickness is a range from multiple of 0.25 to 0.34 of the section thickness. Also, the rib height and rib draft angle are not major factors that can change the sink amount.

  18. Hybrid rib-slot-rib plasmonic waveguide with deep-subwavelength mode confinement and long propagation length

    Directory of Open Access Journals (Sweden)

    Kai Zheng

    2016-08-01

    Full Text Available We propose a hybrid plasmonic waveguide where a combined rib-slot-rib structure is added on the metal substrate within a low-index gap region. The optical properties of the quasi-TM fundamental mode are numerically calculated using the finite element method. Compared to the traditional hybrid plasmonic waveguide, our designed waveguiding structure can support modes with tighter confinement and longer propagation length, by properly adjusting the geometry of the rib-slot-rib structure and the gap height. In details, it can provide the hybrid mode with mode area λ2/12000 and reasonable propagation distance 23.78 μm, simultaneously. Its excellent optical performance can facilitate potential applications in ultra-compact nanophotonic devices and circuits.

  19. Tree height-diameter and yield functions for Gmelina arborea (roxb ...

    African Journals Online (AJOL)

    Data were analyzed using descriptive statistics and regression analysis. Linear, logarithmic, polynomial, power and exponential height-diameter and stem volume models were fitted to the dataset. The predictor was tree Dbh (cm). The developed models were assessed using coefficient of determination (R2) and root mean ...

  20. Experiments on hydraulically-compensated Compressed Air Energy Storage (CAES) system using large-diameter vertical pipe two-phase flow test facility: test facility and test procedure

    International Nuclear Information System (INIS)

    Ohtsu, Iwao; Murata, Hideo; Kukita, Yutaka; Kumamaru, Hiroshige.

    1996-07-01

    JAERI, the University of Tokyo, the Central Research Institute of Electric Power Industry and Shimizu Corporation jointing performed and experimental study on two-phase flow in the hydraulically-compensated Compressed Air Energy Storage (CAES) system with a large-diameter vertical pipe two-phase flow test facility from 1993 to 1995. A hydraulically-compensated CAES system is a proposed, conceptual energy storage system where energy is stored in the form of compressed air in an underground cavern which is sealed by a deep (several hundred meters) water shaft. The shaft water head maintains a constant pressure in the cavern, of several mega Pascals, even during loading or unloading of the cavern with air. The dissolved air in the water, however, may create voids in the shaft when the water rises through the shaft during the loading, being forced by the air flow into the cavern. The voids may reduce the effective head of the shaft, and thus the seal may fail, if significant bubbling should occur in the shaft. This bubbling phenomenon (termed 'Champaign effect') and potential failure of the water seal ('blowout') are simulated in a scaled-height, scaled-diameter facility. Carbon dioxide is used to simulate high solubility of air in the full-height, full-pressure system. This report describes the expected and potential two-phase flow phenomena in a hydraulically-compensated CAES system, the test facility and the test procedure, a method to estimate quantities which are not directly measured by using measured quantities and hydrodynamic basic equations, and desirable additional instrumentation. (author)

  1. Incorporating shape constraints in generalized additive modelling of the height-diameter relationship for Norway spruce

    Directory of Open Access Journals (Sweden)

    Natalya Pya

    2016-02-01

    Full Text Available Background: Measurements of tree heights and diameters are essential in forest assessment and modelling. Tree heights are used for estimating timber volume, site index and other important variables related to forest growth and yield, succession and carbon budget models. However, the diameter at breast height (dbh can be more accurately obtained and at lower cost, than total tree height. Hence, generalized height-diameter (h-d models that predict tree height from dbh, age and other covariates are needed. For a more flexible but biologically plausible estimation of covariate effects we use shape constrained generalized additive models as an extension of existing h-d model approaches. We use causal site parameters such as index of aridity to enhance the generality and causality of the models and to enable predictions under projected changeable climatic conditions. Methods: We develop unconstrained generalized additive models (GAM and shape constrained generalized additive models (SCAM for investigating the possible effects of tree-specific parameters such as tree age, relative diameter at breast height, and site-specific parameters such as index of aridity and sum of daily mean temperature during vegetation period, on the h-d relationship of forests in Lower Saxony, Germany. Results: Some of the derived effects, e.g. effects of age, index of aridity and sum of daily mean temperature have significantly non-linear pattern. The need for using SCAM results from the fact that some of the model effects show partially implausible patterns especially at the boundaries of data ranges. The derived model predicts monotonically increasing levels of tree height with increasing age and temperature sum and decreasing aridity and social rank of a tree within a stand. The definition of constraints leads only to marginal or minor decline in the model statistics like AIC. An observed structured spatial trend in tree height is modelled via 2-dimensional surface

  2. The importance of hydraulic architecture to the distribution patterns of trees in a central Amazonian forest.

    Science.gov (United States)

    Cosme, Luiza H M; Schietti, Juliana; Costa, Flávia R C; Oliveira, Rafael S

    2017-07-01

    Species distributions and assemblage composition may be the result of trait selection through environmental filters. Here, we ask whether filtering of species at the local scale could be attributed to their hydraulic architectural traits, revealing the basis of hydrological microhabitat partitioning in a Central Amazonian forest. We analyzed the hydraulic characteristics at tissue (anatomical traits, wood specific gravity (WSG)), organ (leaf area, specific leaf area (SLA), leaf area : sapwood area ratio) and whole-plant (height) levels for 28 pairs of congeneric species from 14 genera restricted to either valleys or plateaus of a terra-firme forest in Central Amazonia. On plateaus, species had higher WSG, but lower mean vessel area, mean vessel hydraulic diameter, sapwood area and SLA than in valleys; traits commonly associated with hydraulic safety. Mean vessel hydraulic diameter and mean vessel area increased with height for both habitats, but leaf area and leaf area : sapwood area ratio investments with tree height declined in valley vs plateau species. [Correction added after online publication 29 March 2017: the preceding sentence has been reworded.] Two strategies for either efficiency or safety were detected, based on vessel size or allocation to sapwood. In conclusion, contrasting hydrological conditions act as environmental filters, generating differences in species composition at the local scale. This has important implications for the prediction of species distributions under future climate change scenarios. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.

  3. Development and evaluation of height diameter at breast models for native Chinese Metasequoia.

    Science.gov (United States)

    Liu, Mu; Feng, Zhongke; Zhang, Zhixiang; Ma, Chenghui; Wang, Mingming; Lian, Bo-Ling; Sun, Renjie; Zhang, Li

    2017-01-01

    Accurate tree height and diameter at breast height (dbh) are important input variables for growth and yield models. A total of 5503 Chinese Metasequoia trees were used in this study. We studied 53 fitted models, of which 7 were linear models and 46 were non-linear models. These models were divided into two groups of single models and multivariate models according to the number of independent variables. The results show that the allometry equation of tree height which has diameter at breast height as independent variable can better reflect the change of tree height; in addition the prediction accuracy of the multivariate composite models is higher than that of the single variable models. Although tree age is not the most important variable in the study of the relationship between tree height and dbh, the consideration of tree age when choosing models and parameters in model selection can make the prediction of tree height more accurate. The amount of data is also an important parameter what can improve the reliability of models. Other variables such as tree height, main dbh and altitude, etc can also affect models. In this study, the method of developing the recommended models for predicting the tree height of native Metasequoias aged 50-485 years is statistically reliable and can be used for reference in predicting the growth and production of mature native Metasequoia.

  4. Development and evaluation of height diameter at breast models for native Chinese Metasequoia.

    Directory of Open Access Journals (Sweden)

    Mu Liu

    Full Text Available Accurate tree height and diameter at breast height (dbh are important input variables for growth and yield models. A total of 5503 Chinese Metasequoia trees were used in this study. We studied 53 fitted models, of which 7 were linear models and 46 were non-linear models. These models were divided into two groups of single models and multivariate models according to the number of independent variables. The results show that the allometry equation of tree height which has diameter at breast height as independent variable can better reflect the change of tree height; in addition the prediction accuracy of the multivariate composite models is higher than that of the single variable models. Although tree age is not the most important variable in the study of the relationship between tree height and dbh, the consideration of tree age when choosing models and parameters in model selection can make the prediction of tree height more accurate. The amount of data is also an important parameter what can improve the reliability of models. Other variables such as tree height, main dbh and altitude, etc can also affect models. In this study, the method of developing the recommended models for predicting the tree height of native Metasequoias aged 50-485 years is statistically reliable and can be used for reference in predicting the growth and production of mature native Metasequoia.

  5. Individual tree diameter, height, and volume functions for longleaf pine

    Science.gov (United States)

    Carlos A. Gonzalez-Benecke; Salvador A. Gezan; Timothy A. Martin; Wendell P. Cropper; Lisa J. Samuelson; Daniel J. Leduc

    2014-01-01

    Currently, little information is available to estimate individual tree attributes for longleaf pine (Pinus palustris Mill.), an important tree species of the southeastern United States. The majority of available models are local, relying on stem diameter outside bark at breast height (dbh, cm) and not including stand-level parameters. We developed...

  6. Turbulent heat transfer and nanofluid flow in a protruded ribbed square passage

    Science.gov (United States)

    Kumar, Sunil; Kothiyal, Alok Darshan; Bisht, Mangal Singh; Kumar, Anil

    In this article, turbulent heat transfer of nanofluid flow in square passage with protruded rib shape is numerically and experimentally studied over Reynolds number ranges of 4000-18000. Different nanoparticles (Al2O3, CuO, and ZnO), with different concentration (φ) range of 1-4% and different nanoparticle diameter (dnp) range of 30-45 nm are disperse in water (base fluid). Several parameters such as stream wise distance (Xs /dp) range of 1.4-2.6, span wise distance (Ys /dp) range of 1.4-2.6, ratio of protruded height to print diameter (ep /dp) range of 0.83-1.67 also studied to find the consequence on thermal and hydrodynamic characteristics. Simulations were carried out to obtain heat and fluid flow behaviour of smooth and ribbed square channel using commercial CFD software, ANSYS 15.0 (Fluent). Renormalization k - ε model was employed to assess the influence of protruded ribs on turbulent flow and velocity field. The outcome indicates that Al2O3 nanofluid has the highest value of average Nusselt number as compare to other nanofluids. The average Nusselt number increases as the concentration increases and it decreases as nanoparticle diameter increases. The thermal hydrodynamic performance parameter based on equal pumping power, average Nusselt number and average friction factor were found to be highest for Al2O3, φ = 0.04, dnp = 30 nm, Xs /dp = 1.8, Ys /dp = 1.8 and ep /dp = 1.0 . The numerical data are compared with the corresponding experimental data. Comparison between CFD and experimental analysis results showed that good agreement as the data fell within ±7.0% error band.

  7. Effects of rotation on flow in an asymmetric rib-roughened duct: LES study

    International Nuclear Information System (INIS)

    Borello, D.; Salvagni, A.; Hanjalić, K.

    2015-01-01

    Highlights: • Ribbed duct reproduces most of the phenomena occurring in internal cooling channels of blade turbines (rotor and stator). • LES analysis of the flow in a ribbed duct was carried out aiming at detecting the influence of rotation on the turbulence. • In destabilizing conditions, rotation enhances turbulence close to the ribbed duct thus enhancing removal of fluid from the wall and improving mixing. • In stabilizing conditions, turbulence is suppressed by rotation close to the ribbed wall. - Abstract: We report on large-eddy simulations (LES) of fully-developed asymmetric flow in a duct of a rectangular cross-section in which square-sectioned, equally-spaced ribs oriented perpendicular to the flow direction, were mounted on one of the walls. The configuration mimics a passage of internal cooling of a gas-turbine blade. The duct flow at a Reynolds number Re = 15,000 (based on hydraulic diameter D_h and bulk flow velocity U_0) was subjected to clock-wise (stabilising) and anti-clock-wise (destabilising) orthogonal rotation at a moderate rotational number Ro = ΩD_h/U_0 = 0.3, where Ω is the angular velocity. The LES results reproduced well the available experimental results of Coletti et al. (2011) (in the mid-plane adjacent to the ribbed wall) and provided insight into the whole duct complementing the reference PIV measurement. We analyzed the effects of stabilising and destabilising rotation on the flow, vortical structures and turbulence statistics by comparison with the non-rotating case. The analysis includes the identification of depth of penetration of the rib-effects into the bulk flow, influence of flow three-dimensionality and the role of secondary motions, all shown to be strongly affected by the rotation and its direction.

  8. Growth characteristics of mangrove seedling in silvofishery pond – the allometric relationship of height, diameter and leaf abundance

    Science.gov (United States)

    Dwi Hastuti, Endah; Budi Hastuti, Rini

    2018-03-01

    Dynamic environment condition of the silvofishery pond should provide an effect on the growth of mangrove seedling. This research aimed to observe the morphometric growth rate of mangrove seedling of Avicennia marina and Rhizophora mucronata planted in the silvofishery pond and to analyze the morphometric growth relationship of height, diameter and leaf number development of mangrove seedling. The research was conducted through field experiment involving mangrove species of A. marina and R. mucronata for 18 months during March 2015 to September 2016, both single structured and mixed structure. The observation was conducted every 13 weeks including seedling height, diameter and number of leaves. Data analysis was conducted by regression to provide the statistical relation between the growth of diameterheight, diameter – number of leaves and height – number of leaves. The result showed that the growth rate of A. marina in single structured pond was ranged from 0.38 – 3.00 cm.wk-1, 0.0015 – 0.0969 cm.wk‑1 and 0.1 – 13.7 leaves.wk‑1 respectively for height, diameter and number of leaves, while in mixed structure was 0.23 – 1.69 cm.wk‑1, 0.0169 – 0.0731 cm.wk‑1 and 0.5 – 14.0 leaves.wk-. The growth of R. mucronata respectively in single and mixed structure were 0.08 – 2.00 cm.wk‑1 and 0.15 – 2.62 cm.wk‑1, 0.0031 – 0.1369 cm.wk‑1 and 0.0008 – 0.0831 cm.wk‑1 and 0.0 – 1.9 leaves.wk‑1 and 0.0 – 1.6 leaves.wk-1respectively for height, diameter and number of leaves. Data analysis showed that the growth of seedling height of Avicennia in the mixed structure was significantly affected by its diameter growth and the number of leaves of Avicennia in single structured was significantly affected by its diameter. While the height, diameter and number of leaves of R. mucronata both in mixed and single structured silvofishery ponds were independent to each other. This research concluded that mangrove seedling growth is varied among

  9. Computed tomography measurement of rib cage morphometry in emphysema.

    Directory of Open Access Journals (Sweden)

    Nicola Sverzellati

    Full Text Available BACKGROUND: Factors determining the shape of the human rib cage are not completely understood. We aimed to quantify the contribution of anthropometric and COPD-related changes to rib cage variability in adult cigarette smokers. METHODS: Rib cage diameters and areas (calculated from the inner surface of the rib cage in 816 smokers with or without COPD, were evaluated at three anatomical levels using computed tomography (CT. CTs were analyzed with software, which allows quantification of total emphysema (emphysema%. The relationship between rib cage measurements and anthropometric factors, lung function indices, and %emphysema were tested using linear regression models. RESULTS: A model that included gender, age, BMI, emphysema%, forced expiratory volume in one second (FEV1%, and forced vital capacity (FVC% fit best with the rib cage measurements (R(2 = 64% for the rib cage area variation at the lower anatomical level. Gender had the biggest impact on rib cage diameter and area (105.3 cm(2; 95% CI: 111.7 to 98.8 for male lower area. Emphysema% was responsible for an increase in size of upper and middle CT areas (up to 5.4 cm(2; 95% CI: 3.0 to 7.8 for an emphysema increase of 5%. Lower rib cage areas decreased as FVC% decreased (5.1 cm(2; 95% CI: 2.5 to 7.6 for 10 percentage points of FVC variation. CONCLUSIONS: This study demonstrates that simple CT measurements can predict rib cage morphometric variability and also highlight relationships between rib cage morphometry and emphysema.

  10. Height-diameter allometry and above ground biomass in tropical montane forests: Insights from the Albertine Rift in Africa.

    Science.gov (United States)

    Imani, Gérard; Boyemba, Faustin; Lewis, Simon; Nabahungu, Nsharwasi Léon; Calders, Kim; Zapfack, Louis; Riera, Bernard; Balegamire, Clarisse; Cuni-Sanchez, Aida

    2017-01-01

    Tropical montane forests provide an important natural laboratory to test ecological theory. While it is well-known that some aspects of forest structure change with altitude, little is known on the effects of altitude on above ground biomass (AGB), particularly with regard to changing height-diameter allometry. To address this we investigate (1) the effects of altitude on height-diameter allometry, (2) how different height-diameter allometric models affect above ground biomass estimates; and (3) how other forest structural, taxonomic and environmental attributes affect above ground biomass using 30 permanent sample plots (1-ha; all trees ≥ 10 cm diameter measured) established between 1250 and 2600 m asl in Kahuzi Biega National Park in eastern Democratic Republic of Congo. Forest structure and species composition differed with increasing altitude, with four forest types identified. Different height-diameter allometric models performed better with the different forest types, as trees got smaller with increasing altitude. Above ground biomass ranged from 168 to 290 Mg ha-1, but there were no significant differences in AGB between forests types, as tree size decreased but stem density increased with increasing altitude. Forest structure had greater effects on above ground biomass than forest diversity. Soil attributes (K and acidity, pH) also significantly affected above ground biomass. Results show how forest structural, taxonomic and environmental attributes affect above ground biomass in African tropical montane forests. They particularly highlight that the use of regional height-diameter models introduces significant biases in above ground biomass estimates, and that different height-diameter models might be preferred for different forest types, and these should be considered in future studies.

  11. Influence of wall ribs on the thermal stratification and self-pressurization in a cryogenic liquid tank

    International Nuclear Information System (INIS)

    Fu, Juan; Sunden, Bengt; Chen, Xiaoqian

    2014-01-01

    Self-pressurization in a cylindrical ribbed tank which is partially filled with liquid hydrogen is investigated numerically under different rib spacing-to-height ratios. The Volume of Fluid (VOF) method is employed as well as a phase change model. Appropriate models are incorporated into the Ansys Fluent by the user-defined functions to carry out the computations. The ribbed surface is modeled as a finned surface and a conjugate transient heat transfer problem is formulated for predicting fluid flow currents and heat transfer. The effect of rib material and shapes is also studied. Numerical results indicate that the pressure rise can be reduced by ribs mounted on the tank wall. This phenomenon is more pronounced as the rib spacing-to-height ratio is reduced. A vortex is observed in the downstream region of each rib when the spacing-to-height has a relatively high value. Evaporation occurs as time elapses due to heat accumulation at the rib surfaces. Pressure starts to rise later with high thermal conductivity ribs and becomes higher with low thermal conductivity ribs when the ribs are of identical configuration in geometry. The final pressure rise seems to be monotonically versus increasing time. The semicircular ribs perform better than rectangular ones in control of the pressure rise and thermal stratification for identical cross sectional area and if the locations are kept the same

  12. Measurement of local void fraction in a ribbed annulus

    International Nuclear Information System (INIS)

    Steimke, J.L.

    1992-01-01

    The computer code FLOWTRAN-TF is used to analyze hypothetical hydraulic accidents for the nuclear reactor at the Savannah River Site. During a hypothetical Large Break Loss-of-Coolant Accident (LOCA), reactor assemblies would contain a two-phase mixture of air and water which flows downward. Reactor assemblies consist of nested, ribbed annuli. Longitudinal ribs divide each annulus into four subchannels. For accident conditions, air and water can flow past ribs from one subchannel to another. For FLOWTRAN-TF to compute the size of those flows, it is necessary to know the local void fraction in the region of the rib. Measurements have previously been made of length-average void fraction in a ribbed annulus. However, no direct measurements were available of local void fraction. Due to the lack of data, a test was designed to measure local void fraction at the rib. One question addressed by the test was whether void fraction at the rib is solely a function of azimuthal-average void fraction or a function of additional variables such as pressure boundary conditions. This report provides a discussion of this test

  13. Extraction of Trees Stem Diameters at Breast Height by Terrestrial Laser Sensor for Selective Cutting

    Directory of Open Access Journals (Sweden)

    Yili ZHENG

    2014-02-01

    Full Text Available In order to assist the operators of the logging harvester automatically and quickly select the appropriate trees for selective cutting, using two-dimensional laser scanner and inertial measurement system, the two-dimensional cloud points of the trunks at breast-height are obtained for several trees. After projection, clustering, linear transformation and fitting for the point clouds data, the parameters of the breast-height-diameters and center locations of the trees are obtained. The calculation is implemented in MATLAB by Polak-Ribiere-Polyak (PRP conjugate gradient algorithm and the result is shown in VC++ environment. Using this method, absolute errors of the breast-height- diameters and center locations are 2.3 cm and (12.4, 11.4 cm respectively, and meet the requirements on the automatically selective cutting of the logging harvester.

  14. Rib fixation for severe chest deformity due to multiple rib fractures.

    Science.gov (United States)

    Igai, Hitoshi; Kamiyoshihara, Mitsuhiro; Nagashima, Toshiteru; Ohtaki, Yoichi

    2012-01-01

    The operative indications for rib fracture repair have been a matter of debate. However, several reports have suggested that flail chest, pain on respiration, and chest deformity/defect are potential conditions for rib fracture repair. We describe our experience of rib fixation in a patient with severe chest deformity due to multiple rib fractures. A 70-year-old woman was admitted with right-sided multiple rib fractures (2nd to 7th) and marked chest wall deformity without flailing caused by an automobile accident. Collapse of the chest wall was observed along the middle anterior axillary line. At 11 days after the injury, surgery was performed to repair the chest deformity, as it was considered to pose a risk of restrictive impairment of pulmonary function or chronic intercostal pain in the future. Operative findings revealed marked displacement of the superior 4 ribs, from the 2nd to the 5th, and collapse of the osseous chest wall towards the thoracic cavity. After exposure of the fracture regions, ribs fixations were performed using rib staplers. The total operation time was 90 minutes, and the collapsed portion of the chest wall along the middle anterior axillary line was reconstructed successfully.

  15. Interaction between sapwood and foliage area in alpine ash (Eucalyptus delegatensis) trees of different heights.

    Science.gov (United States)

    Mokany, Karel; McMurtrie, Ross E; Atwell, Brian J; Keith, Heather

    2003-10-01

    In native stands of Eucalyptus delegatensis R. T. Baker, sapwood area (As) to foliage area (Af) ratios (As:Af) decreased as tree height increased, contradicting the common interpretation of the Pipe Model Theory as well as the generally observed trend of increasing As:Af ratios with tree height. To clarify this relationship, we estimated sapwood hydraulic conductivity theoretically based on measurements of sapwood vessel diameters and Poiseuille's law for fluid flow through pipes. Despite the observed decrease in As:Af ratios with tree height, leaf specific conductivity increased with total tree height, largely as a result of an increase in the specific conductivity of sapwood. This observation supports the proposition that the stem's ability to supply foliage with water must increase as trees grow taller, to compensate for the increased hydraulic path length. The results presented here highlight the importance of measuring sapwood hydraulic conductivity in analyses of sapwood-foliage interactions, and suggest that measurements of sapwood hydraulic conductivity may help to resolve conflicting observations of how As:Af ratios change as trees grow taller.

  16. Validation and implementation of sandwich structure bottom plate to rib weld joint in the base section of ITER Cryostat

    Energy Technology Data Exchange (ETDEWEB)

    Prajapati, Rajnikant, E-mail: rajnikant@iter-india.org [ITER-India, Institute For Plasma Research, A-29, GIDC Electronics Estate, Sector-25, Gandhinagar 382016 (India); Bhardwaj, Anil K.; Gupta, Girish; Joshi, Vaibhav; Patel, Mitul; Bhavsar, Jagrut; More, Vipul; Jindal, Mukesh; Bhattacharya, Avik; Jogi, Gaurav; Palaliya, Amit; Jha, Saroj; Pandey, Manish [ITER-India, Institute For Plasma Research, A-29, GIDC Electronics Estate, Sector-25, Gandhinagar 382016 (India); Jadhav, Pandurang; Desai, Hemal [Larsen & Toubro Limited, Heavy Engineering, Hazira Manufacturing Complex, Gujarat (India)

    2016-11-01

    Highlights: • ITER Cryostat base section sandwich structure bottom plate to rib weld joint is qualified through mock-up. • Established welding sequence was successfully implemented on all six sectors of cryostat base section. • Each layer liquid penetrant examination has been carried out for these weld joints and found satisfactory. - Abstract: Cryostat is a large stainless steel vacuum vessel providing vacuum environment to ITER machine components. The cryostat is ∼30 m in diameter and ∼30 m in height having variable thickness from 25 mm to 180 mm. Sandwich structure of cryostat base section withstands vacuum loading and limits the deformation under service conditions. Sandwich structure consists of top and bottom plates internally strengthened with radial and circular ribs. In current work, sandwich structure bottom plate to rib weld joint has been designed with full penetration joint as per ITER Vacuum Handbook requirement considering nondestructive examinations and welding feasibility. Since this joint was outside the scope of ASME Section VIII Div. 2, it was decided to validate through mock-up of bottom plate to rib joint. Welding sequence was established to control the distortion. Tensile test, macro-structural examination and layer by layer LPE were carried out for validation of this weld joint. However possibility of ultrasonic examination method was also investigated. The test results from the welded joint mock-up were found to confirm all code and specification requirements. The same was implemented in first sector (0–60°) of base section sandwich structure.

  17. LBA-ECO ND-02 Secondary Forest Tree Heights and Diameters, Para, Brazil: 1999-2005

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: This data set provides tree diameters and heights measured from 1999 to 2005 in plots of a secondary-growth forest fertilization experiment located 6.5-km...

  18. LBA-ECO ND-02 Secondary Forest Tree Heights and Diameters, Para, Brazil: 1999-2005

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set provides tree diameters and heights measured from 1999 to 2005 in plots of a secondary-growth forest fertilization experiment located 6.5-km northwest...

  19. Thermal-hydraulics of helium cooled First Wall channels and scoping investigations on performance improvement by application of ribs and mixing devices

    Energy Technology Data Exchange (ETDEWEB)

    Arbeiter, Frederik, E-mail: frederik.arbeiter@kit.edu [Karlsruhe Institute of Technology, Institute of Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Bachmann, Christian [EUROfusion – Programme Management Unit, Garching (Germany); Chen, Yuming; Ilić, Milica; Schwab, Florian [Karlsruhe Institute of Technology, Institute of Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Sieglin, Bernhard [Max-Planck-Institut für Plasmaphysik, Garching (Germany); Wenninger, Ronald [EUROfusion – Programme Management Unit, Garching (Germany)

    2016-11-01

    Highlights: • Existing first wall designs and expected plasma heat loads are reviewed. • Heat transfer enhancement methods are investigated by CFD. • The results for heat transfer and friction are given, compared and explained. • Relations for needed pumping power and gained thermal heat are shown. • A range for the maximum permissible heat loads from the plasma is estimated. - Abstract: The first wall (FW) of DEMO is a component with high thermal loads. The cooling of the FW has to comply with the material's upper and lower temperature limits and requirements from stress assessment, like low temperature gradients. Also, the cooling has to be integrated into the balance-of-plant, in a sense to deliver exergy to the power cycle and require a limited pumping power for coolant circulation. This paper deals with the basics of FW cooling and proposes optimization approaches. The effectiveness of several heat transfer enhancement techniques is investigated for the use in helium cooled FW designs for DEMO. Among these are wall-mounted ribs, large scale mixing devices and modified hydraulic diameter. Their performance is assessed by computational fluid dynamics (CFD), and heat transfer coefficients and pressure drop are compared. Based on the results, an extrapolation to high heat fluxes is tried to estimate the higher limits of cooling capabilities.

  20. [Internal fixation treatment of multiple rib fractures with absorbable rib-connecting-pins].

    Science.gov (United States)

    Liu, Jinliang; Li, Keyao; He, Jianning

    2011-01-01

    To study the indications, methods, and therapeutic effect of absorbable rib-connecting-pins fixation in the treatment of multiple rib fractures. Between March 2007 and September 2009, 40 patients with multiple rib fractures received internal fixation with absorbable rib-connecting-pins, including 8 one-side flail chest and 1 two-side flail chest. There were 32 males and 8 females with an average age of 39.8 years (range, 25-72 years). The injury was caused by traffic accident in 32 cases, falling from height in 6 cases, and blunt hitting in 2 cases. Preoperatively, imaging data of the chest X-ray or spiral CT three-dimensional (3D) examination showed that all patients had multiple ribs fractures and displacement. The number of fractured ribs was 4-10 (median, 6), and the fracture location ranged from the 2nd to the 10th ribs. Of them, 28 cases were accompanied by hemathorax, pneumothorax or hemopneumothorax; 5 cases by thoracic organ injury; and 10 cases by other part trauma. The time from injury to hospitalization was less than 1 day in 26 cases, 1-3 days in 12 cases, and 3-6 days in 2 cases, and the time from hospitalization to operation was 3 hours to 3 days (mean, 1.2 days). The median fixation rib number was 5 (range, 3-8). The mean operative time, the time in bed, and hospitalization days were 32 minutes (range, 15-50 minutes), 4.5 days (range, 2-7 days), and 11.2 days (range, 5-18 days), respectively. All incisions healed by first intention. No pulmonary infection, pulmonary atelectasis, intrathoracic infection or other complications occurred. All cases were followed up 6-12 months (mean, 8 months). PaO2 [(86.6 +/- 2.2) mmHg (1 mm Hg = 0.133 kPa)] and SpO2 (97.2% +/- 0.6%) at 2 hours after operation were obviously improved when compared with preoperative ones (PaO2 (53.6 + 4.7) mm Hg and SpO2 (86.2% + 1.8%)], showing significant differences (t = 2.971, P = 0.005; t = 2.426, P = 0.020). The chest X-ray films or spiral CT 3D indicated that fracture of rib

  1. Increases of Chamber Height and Base Diameter Have Contrasting Effects on Grazing Rate of Two Cladoceran Species: Implications for Microcosm Studies

    Science.gov (United States)

    Pan, Ying; Zhang, Yunshu; Peng, Yan; Zhao, Qinghua; Sun, Shucun

    2015-01-01

    Aquatic microcosm studies often increase either chamber height or base diameter (to increase water volume) to test spatial ecology theories such as “scale” effects on ecological processes, but it is unclear whether the increase of chamber height or base diameter have the same effect on the processes, i.e., whether the effect of the shape of three-dimensional spaces is significant. We orthogonally manipulated chamber height and base diameter and determined swimming activity, average swimming velocity and grazing rates of the cladocerans Daphnia magna and Moina micrura (on two algae Scenedesmus quadricauda and Chlorella vulgaris; leading to four aquatic algae-cladoceran systems in total) under different microcosm conditions. Across all the four aquatic systems, increasing chamber height at a given base diameter significantly decreased the duration and velocity of horizontal swimming, and it tended to increase the duration but decrease the velocity of vertical swimming. These collectively led to decreases in both average swimming velocity and grazing rate of the cladocerans in the tall chambers (at a given base diameter), in accordance with the positive relationship between average swimming velocity and grazing rate. In contrast, an increase of base diameter at a given chamber height showed contrasting effects on the above parameters. Consistently, at a given chamber volume increasing ratio of chamber height to base diameter decreased the average swimming velocity and grazing rate across all the aquatic systems. In general, increasing chamber depth and base diameter may exert contrasting effects on zooplankton behavior and thus phytoplankton-zooplankton interactions. We suggest that spatial shape plays an important role in determining ecological process and thus should be considered in a theoretical framework of spatial ecology and also the physical setting of aquatic microcosm experiments. PMID:26273836

  2. Hydrodynamics and Heat Transfer in Flow over Rectangular Ribs on the Initially Smooth Surface

    Directory of Open Access Journals (Sweden)

    V. N. Afanasiev

    2017-01-01

    Full Text Available An efficiency of the heat exchange equipment and reducing their weight and size parameters can be considerably improved by using the optimal methods of heat transfer enhancement, which include a two-dimensional roughness, i.e. ribs, backward-facing steps, cavities, etc. deposited on the heat transfer surface. Their shape, sizes and positional relationship have a significant impact on the structure of the boundary layer and its exchange processes.As known, the most affordable and effective method of controlled influence on the structure of turbulent flow is to create a separation zone or other organized vortex structure in it. In order to successfully use the separation zone, it is necessary to know the mechanism of their interaction with the main turbulent flow and the mechanism of the process in separation zone itself. Heat transfer enhancement is provided mainly due to roughness impact on hydrodynamics of turbulent flow, if the rib height h does not exceed the thickness of the viscous sublayer, since heat transfer enhancement arises from breaking and destruction of viscous sublayer produced by the roughness ribs and emerging vortex zones – sources of turbulence. Usually, the height of ribs y+ ≈ 50, and the distance between them along the streamlined surface is 10-20 times greater. The coefficient of friction also increases, but if the height of ribs is sufficiently small and most of them are in the sublayer, the increase of the friction factor will not exceed the increase of the heat transfer coefficient.The paper presents results of experimental investigation of hydrodynamics and heat transfer in the separation zone before and after a rib and in the area of two rectangular ribs with the height of y+ £ 60. The ribs are placed on the flat plate and heated according to the law of qw = const. The structure of turbulent boundary layer from the standpoint of the universal logarithmic law of velocity distribution has been experimentally

  3. Comparison of height-diameter models based on geographically weighted regressions and linear mixed modelling applied to large scale forest inventory data

    Energy Technology Data Exchange (ETDEWEB)

    Quirós Segovia, M.; Condés Ruiz, S.; Drápela, K.

    2016-07-01

    Aim of the study: The main objective of this study was to test Geographically Weighted Regression (GWR) for developing height-diameter curves for forests on a large scale and to compare it with Linear Mixed Models (LMM). Area of study: Monospecific stands of Pinus halepensis Mill. located in the region of Murcia (Southeast Spain). Materials and Methods: The dataset consisted of 230 sample plots (2582 trees) from the Third Spanish National Forest Inventory (SNFI) randomly split into training data (152 plots) and validation data (78 plots). Two different methodologies were used for modelling local (Petterson) and generalized height-diameter relationships (Cañadas I): GWR, with different bandwidths, and linear mixed models. Finally, the quality of the estimated models was compared throughout statistical analysis. Main results: In general, both LMM and GWR provide better prediction capability when applied to a generalized height-diameter function than when applied to a local one, with R2 values increasing from around 0.6 to 0.7 in the model validation. Bias and RMSE were also lower for the generalized function. However, error analysis showed that there were no large differences between these two methodologies, evidencing that GWR provides results which are as good as the more frequently used LMM methodology, at least when no additional measurements are available for calibrating. Research highlights: GWR is a type of spatial analysis for exploring spatially heterogeneous processes. GWR can model spatial variation in tree height-diameter relationship and its regression quality is comparable to LMM. The advantage of GWR over LMM is the possibility to determine the spatial location of every parameter without additional measurements. Abbreviations: GWR (Geographically Weighted Regression); LMM (Linear Mixed Model); SNFI (Spanish National Forest Inventory). (Author)

  4. Correlations between some physiographic factors and diameter, height and cone characteristics in stone pine (Pinus pinea L. afforestation areas in Balıkesir-Burhaniye region

    Directory of Open Access Journals (Sweden)

    Ali Ömer Üçler

    2017-11-01

    Full Text Available In this study, effects of some physiographic factors (aspect, slope and elevation on breast diameter, height and cone properties (cone weight, number of cones, cone width and cone length in stone pine (Pinus pinea L. afforestation areas in Balıkesir-Burhaniye region were investigated. To determine to effects of physiographic conditions, study area is separated according to aspect, slope and elevation groups. Aspect is separated two groups which are shady aspect (B1 and sunny aspect (B2. Slope is separated two groups which are small from 36 percent (E1 and big from 36 percent (E2. Elevation also is separated two groups which are under 400 meters (Y1 and over 400 meters (Y2. Sample areas were scattering to land classifications by using Stratified Sampling Method. Thus, each aspect, slope and elevation classifications were obtained from sample area where are provided from 32 different areas. Tree heights, the diameter at breast height and cone number were measured on saplings. In addition, in each sample area five Pinus pinea trees were selected. It was measured cone diameter, cone height and air-dries weight values of cones which are picked from selecting trees. According to statistical analysis results, aspect effects to tree heights, cone number and cone weight; slope effects the diameter at breast height, cone number and cone diameter; elevation effects the diameter at breast height, tree height, cone number and cone weight. In terms of tree height and diameter values; the highest average breast height diameter was found in the B1E1Y1 with 13.6 cm, and the highest average height value was found in the B2E2Y2 by interaction. In terms of cone characteristics; with the highest average cone number of 8.5 in B1E1Y1, the highest mean cone weight in B1E1Y1 with 232 gr and the highest cone diameter in B2E2Y1 with 5.4 cm. According to the results of correlation analysis; it was determined that slope and elevation factors have positive effect on breast

  5. Corrosion of Spiral Rib Aluminized Pipe

    Science.gov (United States)

    2012-08-01

    Large diameter, corrugated steel pipes are a common sight in the culverts that run alongside many Florida roads. Spiral-ribbed aluminized pipe (SRAP) has been widely specified by the Florida Department of Transportation (FDOT) for runoff drainage. Th...

  6. Tuberlent heat transfer and friction in four-wall convergent/divergent square channels with one ribbed wall

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Soo Whan; Lee, Myung Sung [Dept. of Mechanical System Engineering, Institute of Marine Industry, Gyeongsang National University, Jinju (Korea, Republic of)

    2015-10-15

    The local heat transfer and pressure drop of developed turbulent flows in convergent/divergent channels with square axial cross-sectional areas were experimentally investigated to improve the channel design, such as a gas turbine cooling system. Square convergent/divergent channels with one ribbed wall were manufactured with a fixed rib height e of 10 mm and a ratio of rib spacing p to height e of 10. The measurement was conducted for Reynolds numbers from 15,000 to 89,000. Convergent, divergent, and straight channels with ratios D{sub ho}/D{sub hi} of 0.75, 1.33, and 1.0, respectively, are considered. Of the three channel types, the ribbed divergent channel was found to produce the best thermal performance under identical flow rate, pumping power, and pressure loss conditions.

  7. Flow Structure and Heat Transfer of Jet Impingement on a Rib-Roughened Flat Plate

    Directory of Open Access Journals (Sweden)

    Abdulrahman H. Alenezi

    2018-06-01

    Full Text Available The jet impingement technique is an effective method to achieve a high heat transfer rate and is widely used in industry. Enhancing the heat transfer rate even minimally will improve the performance of many engineering systems and applications. In this numerical study, the convective heat transfer process between orthogonal air jet impingement on a smooth, horizontal surface and a roughened uniformly heated flat plate is studied. The roughness element takes the form of a circular rib of square cross-section positioned at different radii around the stagnation point. At each location, the effect of the roughness element on heat transfer rate was simulated for six different heights and the optimum rib location and rib dimension determined. The average Nusselt number has been evaluated within and beyond the stagnation region to better quantify the heat transfer advantages of ribbed surfaces over smooth surfaces. The results showed both flow and heat transfer features vary significantly with rib dimension and location on the heated surface. This variation in the streamwise direction included both augmentation and decrease in heat transfer rate when compared to the baseline no-rib case. The enhancement in normalized averaged Nusselt number obtained by placing the rib at the most optimum radial location R/D = 2 was 15.6% compared to the baseline case. It was also found that the maximum average Nusselt number for each location was achieved when the rib height was close to the corresponding boundary layer thickness of the smooth surface at the same rib position.

  8. Exercise-induced rib stress fractures: influence of reduced bone mineral density

    DEFF Research Database (Denmark)

    Vinther, Anders; Kanstrup, Inge-Lis; Christiansen, Erik

    2005-01-01

    study investigated BMD in seven Danish national team rowers with previous rib stress fracture (RSF) and 7 controls (C) matched for gender, age, height, weight and training experience. Total body scan and specific scans of the lumbar spine (L2-L4), femoral neck and distal radius were performed using......Exercise-induced rib stress fractures have been reported frequently in elite rowers during the past decade. The etiology of rib stress fractures is unclear, but low bone mineral density (BMD) has been suggested to be a potential risk factor for stress fractures in weight-bearing bones. The present...... density may be a potential risk factor for the development of exercise-induced rib stress fractures in elite rowers....

  9. Thermo-hydraulic performance of solar air heater having multiple v-shaped rib roughness on absorber plates

    Directory of Open Access Journals (Sweden)

    Dhananjay Kumar

    2018-03-01

    Full Text Available This paper presents the performance analysis of the effect of geometrical parameters having multiple v-shaped rib roughness on the airflow side of the absorber plates. Mathematical approach and solution procedure for the analysis of such a solar air heater has been developed theoretically and MATLAB code generated for the solution of the mathematical equations. The effect of parameters such as flow Reynolds number and Relative roughness height on the thermohydraulic performance have been examined and compared with the conventional flat plate solar air heater. A substantial improvement in thermal efficiency of roughened solar air heater as compared to smooth one due to appreciable enhancement in heat transfer coefficient. The enhancement in heat transfer coefficient is also accompanied by a considerable enhancement in pumping power requirement due to the increase in friction factor.

  10. Traumatic Vertebral Fractures and Concomitant Fractures of the Rib in Southwest China, 2001 to 2010

    Science.gov (United States)

    Wang, Hongwei; Zhou, Yue; Ou, Lan; Li, Changqing; Liu, Jun; Xiang, Liangbi

    2015-01-01

    Abstract To our knowledge, the clinical characteristics of traumatic vertebral fractures and concomitant fractures of the rib (TVF-RF) have not been described in previous studies. To investigate the clinical characteristics of patients managed for TVF-RF. A retrospective study of 3142 patients who presented with traumatic vertebral fractures was performed. Two hundred twenty-six patients (7.2%) suffered from TVF-RF. Incidence rate ratios were then calculated with respect to the level of injury to the spine, the ASIA classification of neurological deficits and age. There were 171 male (75.7%) and 55 female (24.3%) patients with a mean age of 43.8 years. The most common mechanisms were falls from high heights in 81 cases and road traffic crashes in 67 cases. Right-sided rib injury occurred in 106 cases, left-sided injury occurred in 76 cases, and bilateral injury occurred in 44 cases. The most frequent location of the rib fractures was from the fourth rib to the ninth rib (70.3%, 510/725). Initial pulmonary complications (IPC) after trauma occurred in 116 cases (51.3%). The mortality rate for the entire group was 1.3% (3/226). The patients with thoracic vertebral fractures and neurological deficits had a higher frequency of multiple rib fractures and IPC than the other patients (P rib fractures, the frequency of IPC and mean intensive care unit (ICU) length of stay also increased. The rates of complications for patients with rib fractures were significantly different from those without rib fractures. We should pay much attention to the patients who presented with thoracic vertebral fractures and neurological deficits for minimizing further complications and mortality in such patients who had a higher frequency of multiple rib fractures and IPC than the other patients. PMID:26554809

  11. Investigation into the heat transfer performance of helically ribbed surfaces

    International Nuclear Information System (INIS)

    Firth, R.J.

    1981-12-01

    The first part of an investigation into flow and heat transfer in annular channels and seven pin clusters is described. One of the main aims of the project is to improve cluster heat transfer prediction codes for helically ribbed surfaces. A study is made of the heat transfer and flow characteristics of a helically ribbed pin in an annular channel. It is shown that the swirling flow, which is induced by the helical ribs, gives rise to substantially enhanced diffusivity levels. This phenomenon had not been taken into account by previous analysis techniques. The methods for analysing heat transfer and pressure drop data from annular channels which were originally developed for non-swirling flow are generalised to accommodate swirling flow. The new methods are shown to be consistent with empirical data. Roughness parameter data is presented for helically ribbed surfaces with an axial rib pitch into height ratio of about 7. (author)

  12. Leaf area compounds height-related hydraulic costs of water transport in Oregon White Oak trees.

    Science.gov (United States)

    N. Phillips; B. J. Bond; N. G. McDowell; Michael G. Ryan; A. Schauer

    2003-01-01

    The ratio of leaf to sapwood area generally decreases with tree size, presumably to moderate hydraulic costs of tree height. This study assessed consequences of tree size and leaf area on water flux in Quercus garryana Dougl. ex. Hook (Oregon White Oak), a species in which leaf to sapwood area ratio increases with tree size. We tested hypotheses that...

  13. Corrosion of Spiral Rib Aluminized Pipe : [Summary

    Science.gov (United States)

    2012-01-01

    Large diameter, corrugated steel pipes are a common sight in the culverts that run alongside many Florida roads. Spiral-ribbed aluminized pipe (SRAP) has been widely specified by the Florida Department of Transportation (FDOT) for runoff drainage. Th...

  14. Analysis of in-R12 CHF data: influence of hydraulic diameter and heating length; test of Weisman boiling crisis model

    International Nuclear Information System (INIS)

    Czop, V.; Herer, C.; Souyri, A.; Garnier, J.

    1993-09-01

    In order to progress on the comprehensive modelling of the boiling crisis phenomenon, Electricite de France (EDF), Commissariat a l'Energie Atomique (CEA) and FRAMATOME have set up experimental programs involving in-R12 tests: the EDF APHRODITE program and the CEA-EDF-FRAMATOME DEBORA program. The first phase in these programs aims to acquire critical heat flux (CHF) data banks, within large thermal-hydraulic parameter ranges, both in cylindrical and annular configurations, and with different hydraulic diameters and heating lengths. Actually, three data banks have been considered in the analysis, all of them concerning in-R12 round tube tests: - the APHRODITE data bank, obtained at EDF with a 13 mn inside diameter, - the DEBORA data bank, obtained at CEA with a 19.2 mm inside diameter, - the KRISTA data bank, obtained at KfK with a 8 mm inside diameter. The analysis was conducted using CHF correlations and with the help of an advanced mathematical tool using pseudo-cubic thin plate type Spline functions. Two conclusions were drawn: -no influence of the heating length on our CHF results, - the influence of the diameter on the CHF cannot be simply expressed by an exponential function of this parameter, as thermal-hydraulic parameters also have an influence. Some calculations with Weisman and Pei theoretical boiling crisis model have been compared to experimental values: fairly good agreement was obtained, but further study must focus on improving the modelling of the influence of pressure and mass velocity. (authors). 12 figs., 4 tabs., 21 refs

  15. Heat transfer in a two-pass internally ribbed turbine blade coolant channel with cylindrical vortex generators

    Energy Technology Data Exchange (ETDEWEB)

    Hibbs, R.; Chen, Y.; Nikitopoulos, D. [Louisiana State Univ., Baton Rouge, LA (United States)] [and others

    1995-10-01

    The effect of vortex generators on the mass (heat) transfer from the ribbed passage of a two pass turbine blade coolant channel is investigated with the intent of optimizing the vortex generator geometry so that significant enhancements in mass/heat transfer can be achieved. In the experimental configuration considered, ribs are mounted on two opposite walls; all four walls along each pass are active and have mass transfer from their surfaces but the ribs are non-participating. Mass transfer measurements, in the form of Sherwood number ratios, are made along the centerline and in selected inter-rib modules. Results are presented for Reynolds number in the range of 5,000 to 40,000, pitch to rib height ratios of 10.5 and 21, and vortex generator-rib spacing to rib height ratios of 0.55, and 1.5. Centerline and spanwise averaged Sherwood number ratios are presented along with contours of the Sherwood number ratios. Results indicate that the vortex generators induce substantial increases in the local mass transfer rates, particularly along the side walls, and modest increases in the average mass transfer rates. The vortex generators have the effect of making the inter-rib profiles along the ribbed walls more uniform. Along the side walls, horse-shoe vortices that characterize the vortex generator wake are associated with significant mass transfer enhancements. The wake effects and the levels of enhancement decrease somewhat with increasing Reynolds number and decreasing pitch.

  16. Computational study on effects of rib height and thickness on heat ...

    Indian Academy of Sciences (India)

    A computational study was carried out for the heat transfer augmentation in a three-dimensional square channel fitted with different types of ribs. The standard k–e model and its two variants (RNG and realizable) were used for turbulence modeling. The predictions were compared with available experimental ...

  17. Analysis and test of a 16-foot radial rib reflector developmental model

    Science.gov (United States)

    Birchenough, Shawn A.

    1989-01-01

    Analytical and experimental modal tests were performed to determine the vibrational characteristics of a 16-foot diameter radial rib reflector model. Single rib analyses and experimental tests provided preliminary information relating to the reflector. A finite element model predicted mode shapes and frequencies of the reflector. The analyses correlated well with the experimental tests, verifying the modeling method used. The results indicate that five related, characteristic mode shapes form a group. The frequencies of the modes are determined by the relative phase of the radial ribs.

  18. Scaling Analysis of the Single-Phase Natural Circulation: the Hydraulic Similarity

    International Nuclear Information System (INIS)

    Yu, Xin-Guo; Choi, Ki-Yong

    2015-01-01

    between the model and the prototype, a set of scaling criteria for exact hydraulic similarity are developed. Particularly, it is found that the scaling of the pipe inner diameter should be scaled down in relation to that of the pipe length, if the exact hydraulic similarity is preserved for a pipe. In addition, the relative pipe length ratio and the cross-sectional area ratio should be kept same between the model and the prototype. Based on the developed scaling criteria, a full pressure reduced-height model is developed with respect a simple prototype loop proposed. In addition, a full-height model is also made

  19. Scaling Analysis of the Single-Phase Natural Circulation: the Hydraulic Similarity

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Xin-Guo; Choi, Ki-Yong [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    between the model and the prototype, a set of scaling criteria for exact hydraulic similarity are developed. Particularly, it is found that the scaling of the pipe inner diameter should be scaled down in relation to that of the pipe length, if the exact hydraulic similarity is preserved for a pipe. In addition, the relative pipe length ratio and the cross-sectional area ratio should be kept same between the model and the prototype. Based on the developed scaling criteria, a full pressure reduced-height model is developed with respect a simple prototype loop proposed. In addition, a full-height model is also made.

  20. Nineth Rib Syndrome after 10(th) Rib Resection.

    Science.gov (United States)

    Yu, Hyun Jeong; Jeong, Yu Sub; Lee, Dong Hoon; Yim, Kyoung Hoon

    2016-07-01

    The 12(th) rib syndrome is a disease that causes pain between the upper abdomen and the lower chest. It is assumed that the impinging on the nerves between the ribs causes pain in the lower chest, upper abdomen, and flank. A 74-year-old female patient visited a pain clinic complaining of pain in her back, and left chest wall at a 7 on the 0-10 Numeric Rating scale (NRS). She had a lateral fixation at T12-L2, 6 years earlier. After the operation, she had multiple osteoporotic compression fractures. When the spine was bent, the patient complained about a sharp pain in the left mid-axillary line and radiating pain toward the abdomen. On physical examination, the 10(th) rib was not felt, and an image of the rib-cage confirmed that the left 10(th) rib was severed. When applying pressure from the legs to the 9(th) rib of the patient, pain was reproduced. Therefore, the patient was diagnosed with 9(th) rib syndrome, and ultrasound-guided 9(th) and 10(th) intercostal nerve blocks were performed around the tips of the severed 10(th) rib. In addition, local anesthetics with triamcinolone were administered into the muscles beneath the 9(th) rib at the point of the greatest tenderness. The patient's pain was reduced to NRS 2 point. In this case, it is suspected that the patient had a partial resection of the left 10(th) rib in the past, and subsequent compression fractures at T8 and T9 led to the deformation of the rib cage, causing the tip of the remaining 10(th) rib to impinge on the 9(th) intercostal nerves, causing pain.

  1. Predicting root biomass of burned and unburned white oak advance reproduction from diameter and height

    Science.gov (United States)

    Benjamin O. Knapp; G. Geoff Wang; David H. Van Lear; Joan L. Walker

    2006-01-01

    The size, especially the root size, of advance oak (Quercus spp.) reproduction provides the best indication of the growth potential after release or top-kill. This study examined the relationship between the size of the root system and various diameter height measurements for small (

  2. The wide-spread presence of rib-like patterns in basal shear of ice streams detected by surface data inversion

    Science.gov (United States)

    Sergienko, O. V.

    2013-12-01

    The direct observations of the basal conditions under continental-scale ice sheets are logistically impossible. A possible approach to estimate conditions at the ice - bed interface is from surface observations by means of inverse methods. The recent advances in remote and ground-based observations have allowed to acquire a wealth observations from Greenland and Antarctic ice sheets. Using high-resolution data sets of ice surface and bed elevations and surface velocities, inversions for basal conditions have been performed for several ice streams in Greenland and Antarctica. The inversion results reveal the wide-spread presence of rib-like spatial structures in basal shear. The analysis of the hydraulic potential distribution shows that these rib-like structures co-locate with highs of the gradient of hydraulic potential. This suggests that subglacial water plays a role in the development and evolution of the basal shear ribs.

  3. Tree Height-Diameter Relationships in the Alpine Treeline Ecotone Compared with Those in Closed Forests on Changbai Mountain, Northeastern China

    Directory of Open Access Journals (Sweden)

    Xiaoyu Wang

    2017-04-01

    Full Text Available Height-diameter relationship is one of the most important stature characteristics of trees. It will change with climatic conditions because height and diameter growth displays different sensitivities to climatic factors such as temperature. Detecting and understanding changes in the stature of trees growing along altitudinal gradients up to their upper limits can help us to better understand the adaptation strategy of trees under global warming conditions. On Changbai Mountain in northeastern China, height-diameter datasets were collected for 2723 Erman’s birch (Betula ermanii Cham. in the alpine treeline ecotone in 2006 and 2013, and for 888 Erman’s birch, spruce (Picea jezoensis Siebold & Zucc. Carr., larch (Larix olgensis A. Henry, and fir (Abies nephrolepis Trautv. ex Maxim. along an altitudinal gradient below the alpine treeline in 2006. These datasets were utilized to explore both changes in the stature of birch at the alpine treeline over time and variations in tree stature of different tree species across altitudes at a given time point (2006. Results showed that birch saplings (<140 cm in height became stunted while birches with a height of >140 cm became more tapered in the alpine treeline ecotone. The stature of birch along the altitudinal gradient became more tapered from 1700 to 1900 m above see level (a.s.l. and then became more stunted from 1900 to 2050 m a.s.l., with 1900 m a.s.l. being the altitudinal inflection point in this pattern. The treeline birch, due to its great temperature magnitude of distribution, displayed higher stature-plasticity in terms of its height-diameter ratio than the lower elevation species studied. The stature of birch is strongly modulated by altitude-related temperature but also co-influenced by other environmental factors such as soil depth and available water, wind speed, and duration and depth of winter snow cover. The high stature-plasticity of birch makes it fare better than other species to

  4. Numerical prediction of augmented turbulent heat transfer in an annular fuel channel with repeated two-dimensional square ribs

    International Nuclear Information System (INIS)

    Takase, K.

    1996-01-01

    The square-ribbed fuel rod for high temperature gas-cooled reactors was designed and developed so as to enhance the turbulent heat transfer in comparison with the previous standard fuel rod. The turbulent heat transfer characteristics in an annular fuel channel with repeated two-dimensional square ribs were analysed numerically on a fully developed incompressible flow using the k-ε turbulence model and the two-dimensional axisymmetrical coordinate system. Numerical analyses were carried out under the conditions of Reynolds numbers from 3000 to 20000 and ratios of square-rib pitch to height of 10, 20 and 40 respectively. The predictions of the heat transfer coefficients agreed well within an error of 10% for the square-rib pitch to height ratio of 10, 20% for 20 and 25% for 40 respectively, with the heat transfer empirical correlations obtained from the experimental data due to the simulated square-ribbed fuel rods. Therefore it was found that the effect of heat transfer augmentation due to the square ribs could be predicted by the present numerical simulations and the mechanism could be explained by the change in the turbulence kinematic energy distribution along the flow direction. (orig.)

  5. A technique to identify annual growth rings in Eucalyptus grandis using annual measurements of diameter at breast height and gamma ray densitometry

    CSIR Research Space (South Africa)

    Naidoo, Sasha

    2010-06-01

    Full Text Available A technique was developed to identify annual growth rings in E. grandis using a combination of annual measurements of diameter at breast height (DBH) from permanent sample plot (PSP) datasets and bark-pith density profiles. By assessing the pattern...

  6. Numerical prediction of turbulent heat transfer augmentation in an annular fuel channel with two-dimensional square ribs

    International Nuclear Information System (INIS)

    Takase, Kazuyuki

    1996-01-01

    The square-ribbed fuel rod for high temperature gas-cooled reactors was developed in order to enhance the turbulent heat transfer in comparison with the standard fuel rod. To evaluate the heat transfer performance of the square-ribbed fuel rod, the turbulent heat transfer coefficients in an annular fuel channel with repeated two-dimensional square ribs were analyzed numerically on a fully developed incompressible flow using the k - ε turbulence model and the two-dimensional axisymmetrical coordinate system. Numerical analyses were carried out for a range of Reynolds numbers from 3000 to 20000 and ratios of square-rib pitch to height of 10, 20 and 40, respectively. The predicted values of the heat transfer coefficients agreed within an error of 10% for the square-rib pitch to height ratio of 10, 20% for 20 and 25% for 40, respectively, with the heat transfer empirical correlations obtained from the experimental data. It was concluded by the present study that the effect of the heat transfer augmentation by square ribs could be predicted sufficiently by the present numerical simulations and also a part of its mechanism could be explained by means of the change in the turbulence kinematic energy distribution along the flow direction. (author)

  7. Design and analysis of hydraulic ram water pumping system

    Science.gov (United States)

    Hussin, N. S. M.; Gamil, S. A.; Amin, N. A. M.; Safar, M. J. A.; Majid, M. S. A.; Kazim, M. N. F. M.; Nasir, N. F. M.

    2017-10-01

    The current pumping system (DC water pump) for agriculture is powered by household electricity, therefore, the cost of electricity will be increased due to the higher electricity consumption. In addition, the water needs to be supplied at different height of trees and different places that are far from the water source. The existing DC water pump can pump the water to 1.5 m height but it cost money for electrical source. The hydraulic ram is a mechanical water pump that suitable used for agriculture purpose. It can be a good substitute for DC water pump in agriculture use. The hydraulic ram water pumping system has ability to pump water using gravitational energy or the kinetic energy through flowing source of water. This project aims to analyze and develop the water ram pump in order to meet the desired delivery head up to 3 meter height with less operation cost. The hydraulic ram is designed using CATIA software. Simulation work has been done using ANSYS CFX software to validate the working concept. There are three design were tested in the experiment study. The best design reached target head of 3 m with 15% efficiency and flow rate of 11.82l/min. The results from this study show that the less diameter of pressure chamber and higher supply head will create higher pressure.

  8. Comparing Johnson’s SBB, Weibull and Logit-Logistic bivariate distributions for modeling tree diameters and heights using copulas

    Energy Technology Data Exchange (ETDEWEB)

    Cardil Forradellas, A.; Molina Terrén, D.M.; Oliveres, J.; Castellnou, M.

    2016-07-01

    Aim of study: In this study we compare the accuracy of three bivariate distributions: Johnson’s SBB, Weibull-2P and LL-2P functions for characterizing the joint distribution of tree diameters and heights. Area of study: North-West of Spain. Material and methods: Diameter and height measurements of 128 plots of pure and even-aged Tasmanian blue gum (Eucalyptus globulus Labill.) stands located in the North-west of Spain were considered in the present study. The SBB bivariate distribution was obtained from SB marginal distributions using a Normal Copula based on a four-parameter logistic transformation. The Plackett Copula was used to obtain the bivariate models from the Weibull and Logit-logistic univariate marginal distributions. The negative logarithm of the maximum likelihood function was used to compare the results and the Wilcoxon signed-rank test was used to compare the related samples of these logarithms calculated for each sample plot and each distribution. Main results: The best results were obtained by using the Plackett copula and the best marginal distribution was the Logit-logistic. Research highlights: The copulas used in this study have shown a good performance for modeling the joint distribution of tree diameters and heights. They could be easily extended for modelling multivariate distributions involving other tree variables, such as tree volume or biomass. (Author)

  9. Development and Evaluation of Models for the Relationship between Tree Height and Diameter at Breast Height for Chinese-Fir Plantations in Subtropical China.

    Science.gov (United States)

    Li, Yan-qiong; Deng, Xiang-wen; Huang, Zhi-hong; Xiang, Wen-hua; Yan, Wen-de; Lei, Pi-feng; Zhou, Xiao-lu; Peng, Chang-hui

    2015-01-01

    Tree diameter at breast height (dbh) and height are the most important variables used in forest inventory and management as well as forest carbon-stock estimation. In order to identify the key stand variables that influence the tree height-dbh relationship and to develop and validate a suit of models for predicting tree height, data from 5961 tree samples aged from 6 years to 53 years and collected from 80 Chinese-fir plantation plots were used to fit 39 models, including 33 nonlinear models and 6 linear models, were developed and evaluated into two groups. The results showed that composite models performed better in height estimate than one-independent-variable models. Nonlinear composite Model 34 and linear composite Model 6 were recommended for predicting tree height in Chinese fir plantations with a dbh range between 4 cm and 40 cm when the dbh data for each tree and the quadratic mean dbh of the stand (Dq) and mean height of the stand (Hm) were available. Moreover, Hm could be estimated by using the formula Hm = 11.707 × l n(Dq)-18.032. Clearly, Dq was the primary stand variable that influenced the height-dbh relationship. The parameters of the models varied according to stand age and site. The inappropriate application of provincial or regional height-dbh models for predicting small tree height at local scale may result in larger uncertainties. The method and the recommended models developed in this study were statistically reliable for applications in growth and yield estimation for even-aged Chinese-fir plantation in Huitong and Changsha. The models could be extended to other regions and to other tree species only after verification in subtropical China.

  10. Traumatic Vertebral Fractures and Concomitant Fractures of the Rib in Southwest China, 2001 to 2010: An Observational Study.

    Science.gov (United States)

    Wang, Hongwei; Zhou, Yue; Ou, Lan; Li, Changqing; Liu, Jun; Xiang, Liangbi

    2015-11-01

    To our knowledge, the clinical characteristics of traumatic vertebral fractures and concomitant fractures of the rib (TVF-RF) have not been described in previous studies.To investigate the clinical characteristics of patients managed for TVF-RF. A retrospective study of 3142 patients who presented with traumatic vertebral fractures was performed. Two hundred twenty-six patients (7.2%) suffered from TVF-RF.Incidence rate ratios were then calculated with respect to the level of injury to the spine, the ASIA classification of neurological deficits and age.There were 171 male (75.7%) and 55 female (24.3%) patients with a mean age of 43.8 years. The most common mechanisms were falls from high heights in 81 cases and road traffic crashes in 67 cases. Right-sided rib injury occurred in 106 cases, left-sided injury occurred in 76 cases, and bilateral injury occurred in 44 cases. The most frequent location of the rib fractures was from the fourth rib to the ninth rib (70.3%, 510/725). Initial pulmonary complications (IPC) after trauma occurred in 116 cases (51.3%). The mortality rate for the entire group was 1.3% (3/226). The patients with thoracic vertebral fractures and neurological deficits had a higher frequency of multiple rib fractures and IPC than the other patients (P the increased number of rib fractures, the frequency of IPC and mean intensive care unit (ICU) length of stay also increased.The rates of complications for patients with rib fractures were significantly different from those without rib fractures. We should pay much attention to the patients who presented with thoracic vertebral fractures and neurological deficits for minimizing further complications and mortality in such patients who had a higher frequency of multiple rib fractures and IPC than the other patients.

  11. How different are the Kebara 2 ribs to modern humans?

    Science.gov (United States)

    Chapman, Tara; Beyer, Benoît; Sholukha, Victor; Semal, Patrick; Feipel, Veronique; Louryan, Stéphane; Van Sint Jan, Serge

    2017-12-30

    This study analyses rib geometric parameters of individual ribs of 14 modern human subjects (7 males and 7 females) in comparison to the reconstructed ribs of the Kebara 2 skeleton which was taken from the reconstruction of a Neandertal thorax by Sawyer & Maley (2005). Three-dimensional (3D) models were segmented from CT scans and each rib vertex cloud was placed into a local coordinate system defined from the rib principal axes. Rib clouds were then analysed using best fitting ellipses of the external contours of the cross-section areas. The centroid of each ellipse was then used to measure the centroidal pathway between each slice (rib midline). Curvature of the ribs was measured from the mid-line of the ribs as the sum of angles between successive centroids in adjacent cross sections. Distinct common patterns were noted in all rib geometric parameters for modern humans. The Kebara 2 reconstructed ribs also followed the same patterns. This study demonstrated that there are differences between the sexes in rib geometrical parameters, with females showing smaller rib width, chord length and arc length, but greater curvature (rib torsion, rib axial curvature, rib anterior-posterior bending) than males. The Kebara 2 reconstructed ribs were within the modern human range for the majority of geometrical parameters.

  12. Painful rib hump: a new clinical sign for detecting intraspinal rib displacement in scoliosis due to neurofibromatosis

    Directory of Open Access Journals (Sweden)

    Katsalouli Marina

    2006-06-01

    Full Text Available Abstract Background Spinal cord compression and associate neurological impairment is rare in patients with scoliosis and neurofibromatosis. Common reasons are vertebral subluxation, dislocation, angulation and tumorous lesions around the spinal canal. Only twelve cases of intraspinal rib dislocation have been reported in the literature. The aim of this report is to present a case of rib penetration through neural foramen at the apex of a scoliotic curve in neurofibromatosis and to introduce a new clinical sign for its detection. Methods A 13-year-old girl was evaluated for progressive left thoracic kyphoscoliotic curve due to a type I neurofibromatosis. Clinical examination revealed multiple large thoracic and abdominal "cafe-au-lait" spots, neurological impairment of the lower limbs and the presence of a thoracic gibbous that was painful to pressure at the level of the left eighth rib (Painful Rib Hump. CT-scan showed detachment and translocation of the cephalic end of the left eighth rib into the adjacent enlarged neural foramen. The M.R.I. examination of the spine showed neither cord abnormality nor neurogenic tumor. Results The patient underwent resection of the intraspinal mobile eighth rib head and posterior spinal instrumentation and was neurologically fully recovered six months postoperatively. Conclusion Spine surgeons should be aware of intraspinal rib displacement in scoliotic curves in neurofibromatosis. Painful rib hump is a valuable diagnostic tool for this rare clinical entity.

  13. Cough-induced rib fractures.

    Science.gov (United States)

    Hanak, Viktor; Hartman, Thomas E; Ryu, Jay H

    2005-07-01

    To define the demographic, clinical, and radiological features of patients with cough-induced rib fractures and to assess potential risk factors. For this retrospective, single-center study, we identified all cases of cough-induced rib fractures diagnosed at the Mayo Clinic in Rochester, Minn, over a 9-year period between January 1, 1996, and January 31, 2005. Bone densitometry data from patients' medical records were analyzed, and T scores were used to classify patients into bone density categories. The mean +/- SD age of the 54 study patients at presentation was 55+/-17 years, and 42 patients (78%) were female. Patients presented with chest wall pain after onset of cough. Rib fracture was associated with chronic cough (> or =3 weeks' duration) in 85% of patients. Rib fractures were documented by chest radiography, rib radiography, computed tomography, or bone scan. Chest radiography had been performed in 52 patients and revealed rib fracture in 30 (58%). There were 112 fractured ribs in 54 patients. One half of patients had more than one fractured rib. Right-sided rib fractures alone were present in 17 patients (26 fractured ribs), left-sided in 23 patients (35 fractured ribs), and bilateral in 14 patients (51 fractured ribs). The most commonly fractured rib on both sides was rib 6. The fractures were most common at the lateral aspect of the rib cage. Bone densitometry was done in 26 patients and revealed osteopenia or osteoporosis in 17 (65%). Cough-induced rib fractures occur primarily in women with chronic cough. Middle ribs along the lateral aspect of the rib cage are affected most commonly. Although reduced bone density is likely a risk factor, cough-induced rib fractures can occur in the presence of normal bone density.

  14. Analytical studies on the impact of using repeated-rib roughness in LMR [Liquid Metal Reactor] decay heat removal systems

    International Nuclear Information System (INIS)

    Obot, N.T.; Tessier, J.H.; Pedersen, D.R.

    1988-01-01

    A numerical study was carried out to determine the effects of roughness on the thermal performance of Liquid Metal Reactor (LMR) decay heat removal systems for a range of possible design configurations and operating conditions. The ranges covered for relative rib height (e/D/sub h/), relative pitch (p/e) and flow attack angle were 0.026--0.103, 5--20 and 0--90 degrees, successively. The heat flux was varied between 1.1 and 21.5 kW/m 2 (0.1 and 2.0 kW/ft 2 ). Calculations were made for three cases: smooth duct with no ribs, ribs on both the guard vessel and collector wall, and ribs on the collector wall only. The results indicate that significant benefits, amounting to nearly two-fold reductions in guard vessel and collector wall temperatures, can be realized by placing repeated ribs on both the guard vessel and the collector wall. The magnitudes of the reduction in the reactor vessel temperature are considerably smaller. In general, the level of improvement, be it with respect to temperature or heat flux, is only mildly affected by changes in rib height or pitch but exhibits greater sensitivity to the assumed value for the system form loss. When the ribs are placed only on the collector wall, the heat removal capability is substantially reduced

  15. Rib Radiography versus Chest Computed Tomography in the Diagnosis of Rib Fractures.

    Science.gov (United States)

    Sano, Atsushi

    2018-05-01

     The accurate diagnosis of rib fractures is important in chest trauma. Diagnostic images following chest trauma are usually obtained via chest X-ray, chest computed tomography, or rib radiography. This study evaluated the diagnostic characteristics of rib radiography and chest computed tomography.  Seventy-five rib fracture patients who underwent both chest computed tomography and rib radiography between April 2008 and December 2013 were included. Rib radiographs, centered on the site of pain, were taken from two directions. Chest computed tomography was performed using a 16-row multidetector scanner with 5-mm slice-pitch without overlap, and axial images were visualized in a bone window.  In total, 217 rib fractures were diagnosed in 75 patients. Rib radiography missed 43 rib fractures in 24 patients. The causes were overlap with organs in 15 cases, trivial fractures in 21 cases, and injury outside the imaging range in 7 cases. Left lower rib fractures were often missed due to overlap with the heart, while middle and lower rib fractures were frequently not diagnosed due to overlap with abdominal organs. Computed tomography missed 21 rib fractures in 17 patients. The causes were horizontal fractures in 10 cases, trivial fractures in 9 cases, and insufficient breath holding in 1 case.  In rib radiography, overlap with organs and fractures outside the imaging range were characteristic reasons for missed diagnoses. In chest computed tomography, horizontal rib fractures and insufficient breath holding were often responsible. We should take these challenges into account when diagnosing rib fractures. Georg Thieme Verlag KG Stuttgart · New York.

  16. Linking plant hydraulics and beta diversity in tropical forests

    Energy Technology Data Exchange (ETDEWEB)

    Christoffersen, Bradley [Earth and Environmental Sciences, Los Alamos National Laboratory, Los Alamos NM 87545 USA; Meir, Patrick [School of GeoSciences, University of Edinburgh, Edinburgh EH9 3FE UK; Research School of Biology, Australian National University, Canberra ACT 2601 Australia; McDowell, Nate G. [Pacific Northwest National Laboratory, Richland WA 99352 USA

    2017-05-31

    In tropical forests, studies of xylem traits governing water transport through plants, or ‘hydraulic architecture’ (Tyree et al., 1991), and changes in species composition across environmental gradients, or ‘beta diversity’ (Gentry, 1988; Ackerly & Cornwell, 2007), have progressedmostly in parallel until recently (Hao et al., 2008; Bartlett et al., 2016). In this issue of New Phytologist, Cosme et al. (pp. 000–5 000) present a timely contribution to the intersection of plant hydraulic architecture (HA) with trait-based community ecology. Building on previous biogeographical work that demonstrated shifts in species composition (beta diversity) across a gradient from valleys to plateaus in central Amazonia (Schietti et al., 2014), Cosme et al. explore how variation in HA might underpin this sorting, sampling pairs of congeneric species restrictedmostly to either plateau or valley habitats. Valley species had significantly lower wood density and higher hydraulically-weighted vessel diameter and vessel area. By contrast, trees with some of the largest hydraulically-weighted vessel diameters existed in tall, deciduous plateau species, while the leaf: sapwood area ratio decreased with height in valley but not plateau species. These intriguing results suggest that species differentiation in water transport traits mediate edaphic filtering along the valley-toplateau gradient, in contrast to previous work where wood mechanical support mediated valley-to-plateau environmental filtering (Fortunel et al., 2014).

  17. Concurrent rib and pelvic fractures as an indicator of solid abdominal organ injury.

    Science.gov (United States)

    Al-Hassani, Ammar; Afifi, Ibrahim; Abdelrahman, Husham; El-Menyar, Ayman; Almadani, Ammar; Recicar, Jan; Al-Thani, Hassan; Maull, Kimball; Latifi, Rifat

    2013-01-01

    To study the association of solid organ injuries (SOIs) in patients with concurrent rib and pelvic fractures. Retrospective analysis of prospectively collected data from November 2007 to May 2010. Patients' demographics, mechanism of injury, Injury severity scoring, pelvic fracture, and SOIs were analyzed. Patients with SOIs were compared in rib fractures with and without pelvic fracture. The study included 829 patients (460 with rib fractures ± pelvic fracture and 369 with pelvic fracture alone) with mean age of 35 ± 12.7 years. Motor vehicle crashes (45%) and falls from height (30%) were the most common mechanism of injury. The overall incidence of SOIs in this study was 22% (185/829). Further, 15% of patient with rib fractures had associated pelvic fracture. SOI was predominant in patients with concurrent rib fracture and pelvic fracture compared to ribs or pelvic fractures alone (42% vs. 26% vs. 15%, respectively, p = 0.02). Concurrent multiple rib fractures and pelvic fracture increases the risk of SOI compared to either group alone. Lower RFs and pelvic fracture had higher association for SOI and could be used as an early indicator of the presence of SOIs. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  18. Sub-Compartment Variation in Tree Height, Stem Diameter and Stocking in a Pinus radiata D. Don Plantation Examined Using Airborne LiDAR Data

    Directory of Open Access Journals (Sweden)

    Hanieh Saremi

    2014-08-01

    Full Text Available Better information regarding the spatial variability of height, Diameter at Breast Height (DBH and stocking could improve inventory estimates at the operational Planning Unit since these parameters are used extensively in allometric equations, including stem volume, biomass and carbon calculations. In this study, the influence of stand stocking on height and DBH of two even aged radiata pine (Pinus radiata D. Don stands were investigated using airborne Light Detection and Ranging (LiDAR data at a study site in New South Wales, Australia. Both stands were characterized by irregular stocking due to patchy establishment and self-thinning in the absence of any silvicultural thinning events. For the purpose of this study, a total of 34 plots from a 34 year old site and 43 plots from a nine year old site were established, from which a total of 447 trees were sampled. Within these plots, DBH and height measurements were measured and their relationships with stocking were evaluated. LiDAR was used for height estimation as well as stem counts in fixed plots (stocking. The results showed a significant relationship between stem DBH and stocking. At both locations, trees with larger diameters were found on lower stocking sites. Height values were also significantly correlated with stocking, with taller trees associated with high stocking. These results were further verified of additional tree samples, with independent field surveys for DBH and LiDAR-derived metrics for height analysis. This study confirmed the relationship between P. radiata tree heights and stem diameter with stocking and demonstrated the capacity of LiDAR to capture sub-compartment variation in these tree-level attributes.

  19. Cough-induced rib fractures.

    Science.gov (United States)

    Sano, Atsushi; Tashiro, Ken; Fukuda, Tsutomu

    2015-10-01

    Occasionally, patients who complain of chest pain after the onset of coughing are diagnosed with rib fractures. We investigated the characteristics of cough-induced rib fractures. Between April 2008 and December 2013, 17 patients were referred to our hospital with chest pain after the onset of coughing. Rib radiography was performed, focusing on the location of the chest pain. When the patient had other signs and symptoms such as fever or persistent cough, computed tomography of the chest was carried out. We analyzed the data retrospectively. Rib fractures were found in 14 of the 17 patients. The age of the patients ranged from 14 to 86 years (median 39.5 years). Ten patients were female and 4 were male. Three patients had chronic lung disease. There was a single rib fracture in 9 patients, and 5 had two or more fractures. The middle and lower ribs were the most commonly involved; the 10th rib was fractured most frequently. Cough-induced rib fractures occur in every age group regardless of the presence or absence of underlying disease. Since rib fractures often occur in the lower and middle ribs, rib radiography is useful for diagnosis. © The Author(s) 2015.

  20. SIMULATION OF TURBULENT FLOW AND HEAT TRANSFER OVER A BACKWARD -FACING STEP WITH RIBS TURBULATORS

    Directory of Open Access Journals (Sweden)

    Khudheyer S Mushatet

    2011-01-01

    Full Text Available Simulation is presented for a backward facing step flow and heat transfer inside a channel with ribs turbulators. The problem was investigated for Reynolds numbers up to 32000. The effect of a step height, the number of ribs and the rib thickness on the flow and thermal field were investigated. The computed results are presented as streamlines counters, velocity vectors and graphs of Nusselt number and turbulent kinetic energy variation. A control volume method employing a staggered grid techniques was imposed to discretize the governing continuity, full Navier Stockes and energy equations. A computer program using a SIMPLE algorithm was developed to handle the considered problem. The effect of turbulence was modeled by using a k-є model with its wall function formulas. The obtained results show that the strength and size of the re-circulation zones behind the step are increased with the increase of contraction ratio(i.e. with the increase of a step height. The size of recirculation regions and the reattachment length after the ribs are decreased with increasing of the contraction ratio. Also the results show that the Reynolds number and contraction ratio have a significant effect on the variation of turbulent kinetic energy and Nusselt number

  1. Application study of magnetic fluid seal in hydraulic turbine

    International Nuclear Information System (INIS)

    Yu, Z Y; Zhang, W

    2012-01-01

    The waterpower resources of our country are abundant, and the hydroelectric power is developed, but at present the main shaft sealing device of hydraulic turbine is easy to wear and tear and the leakage is great. The magnetic fluid seal has the advantages of no contact, no wear, self-healing, long life and so on. In this paper, the magnetic fluid seal would be used in the main shaft of hydraulic turbine, the sealing structure was built the model, meshed the geometry, applied loads and solved by using MULTIPHYSICS in ANSYS software, the influence of the various sealing structural parameters such as tooth width, height, slot width, sealing gap on the sealing property were analyzed, the magnetic fluid sealing device suitable for large-diameter shaft and sealing water was designed, the sealing problem of the hydraulic turbine main shaft was solved effectively which will bring huge economic benefits.

  2. Parametric study on thermal-hydraulic characteristics of high conversion light water reactor

    International Nuclear Information System (INIS)

    Mori, Takamasa; Nakagawa, Masayuki; Fujii, Sadao.

    1988-11-01

    To assess the feasibility of high conversion light water reactors (HCLWRs) from the thermal-hydraulic viewpoint, parametric study on thermal-hydraulic characteristics of HCLWR has been carried out by using a unit cell model. It is assumed that a HCLWR core is contained in a current 1000 MWe PWR plant. At the present study, reactor core parameters such as fuel pin diameter, pitch, core height and linear heat rate are widely and parametrically changed to survey the relation between these parameters and the basic thermal-hydraulic characteristics, i.e. maximum fuel temperature, minimum DNBR, reduction of reactor thermal output and so on. The validity of the unit cell model used has been ensured by comparison with the result of a subchannel analysis carried out for a whole core. (author)

  3. Increasing heat transfer of non-Newtonian nanofluid in rectangular microchannel with triangular ribs

    Science.gov (United States)

    Shamsi, Mohammad Reza; Akbari, Omid Ali; Marzban, Ali; Toghraie, Davood; Mashayekhi, Ramin

    2017-09-01

    In this study, computational fluid dynamics and the laminar flow of the non-Newtonian fluid have been numerically studied. The cooling fluid includes water and 0.5 wt% Carboxy methyl cellulose (CMC) making the non-Newtonian fluid. In order to make the best of non-Newtonian nanofluid in this simulation, solid nanoparticles of Aluminum Oxide have been added to the non-Newtonian fluid in volume fractions of 0-2% with diameters of 25, 45 and 100 nm. The supposed microchannel is rectangular and two-dimensional in Cartesian coordination. The power law has been used to speculate the dynamic viscosity of the cooling nanofluid. The field of numerical solution is simulated in the Reynolds number range of 5 nanoparticles as well as the use for nanoparticles with smaller diameters lead to greater heat transfer. Among all the studied forms, the triangular rib from with an angle of attack 30° has the biggest Nusselt number and the smallest pressure drop along the microchannel. Also, an increase in the angle of attack and as a result of a sudden contact between the fluid and the ribs and also a reduction in the coflowing length (length of the rib) cause a cut in heat transfer by the fluid in farther parts from the solid wall (tip of the rib).

  4. A study of the rib fall mechanism in soft coal and its control at a fully-mechanized top-coal caving face

    Energy Technology Data Exchange (ETDEWEB)

    Fang Xin-qiu; He Jie; Li Hai-chao [China University of Mining & Technology, Xuzhou (China). School of Mines

    2009-05-15

    The factors involved in rib-fall at a fully-mechanized top-coal caving face in the Wuyang mine were analyzed. The mechanical stress characteristics and the mechanism of rib-fall were modeled. Control principles and methods were proposed and a control project, and parameters for it, was identified. An underground industrial scale test was subsequently completed. The results show that arc shaped 'sliding surfaces' exist in the rib. The critical height of stable areas is 1.8 meters. The key to rib stability is the control of this arc shaped surface. Wooden bolts are used in the serious rib-fall zone to stabilize the rib. After implementation of the new project rib fall depth and scope were reduced significantly and tip-to-face caving was effectively controlled. 10 refs., 5 figs.

  5. Surgical rib fixation

    OpenAIRE

    Marasco, Silvana

    2017-01-01

    Traumatic rib fracture injuries are being seen with increasing frequency in the hospital setting. They are often associated with other severe injuries and frequently require admission. The most severe form of rib fracture injury, flail chest, has a mortality of up to 33%. Rib fracture injuries have also been associated with chronic pain, malunion, deformity, disability and poor quality of life. Despite this, the standard of management for rib fracture injuries was, and in most ...

  6. The transverse diameter of the chest on routine radiographs reliably estimates gestational age and weight in premature infants.

    Science.gov (United States)

    Dietz, Kelly R; Zhang, Lei; Seidel, Frank G

    2015-08-01

    Prior to digital radiography it was possible for a radiologist to easily estimate the size of a patient on an analog film. Because variable magnification may be applied at the time of processing an image, it is now more difficult to visually estimate an infant's size on the monitor. Since gestational age and weight significantly impact the differential diagnosis of neonatal diseases and determine the expected size of kidneys or appearance of the brain by MRI or US, this information is useful to a pediatric radiologist. Although this information may be present in the electronic medical record, it is frequently not readily available to the pediatric radiologist at the time of image interpretation. To determine if there was a correlation between gestational age and weight of a premature infant with their transverse chest diameter (rib to rib) on admission chest radiographs. This retrospective study was approved by the institutional review board, which waived informed consent. The maximum transverse chest diameter outer rib to outer rib was measured on admission portable chest radiographs of 464 patients admitted to the neonatal intensive care unit (NICU) during the 2010 calendar year. Regression analysis was used to investigate the association between chest diameter and gestational age/birth weight. Quadratic term of chest diameter was used in the regression model. Chest diameter was statistically significantly associated with both gestational age (P chest diameter on digital chest radiograph with the tables and graphs in our study.

  7. Heat transfer and friction characteristics in steam cooled rectangular channels with rib turbulators

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Jianying; Gao, Tieyu; Li, Guojun [Xi' an Jiaotong University, Xi' an (China)

    2014-01-15

    We studied the heat transfer and friction characteristics in steam-cooled rectangular channels with rib turbulators on W side or H side walls in the Reynolds number (Re) range of 10000-80000. Each of the test channels was welded by four stainless steel plates to simulate the actual geometry and heat transfer structure of blade/vane internal cooling passage. The length of the channel L was 1000 mm, the cross section of the channel was 40 mm X 80 mm, and the pitch-to-rib height ratio p/e was kept at 10. The channel blockage ratio (W/H) was 0.047. Results showed that the Nusselt number (Nu) distributions displayed different trends at the entrance region with the increase of Re for the rib turbulators on the W side walls. The heat transfer performance of the rib turbulators on the H side walls was about 24- 27% higher than that on the W side walls at the same pumping power. In addition, semi-empirical correlations for the two cases, rib turbulators on W side walls and rib turbulators on H side walls, were developed based on the heat transfer results, which could be used in the design of the internal cooling passage of new generation steam-cooled gas turbine blade/vane.

  8. Rib Fractures

    Science.gov (United States)

    ... Video) Achilles Tendon Tear Additional Content Medical News Rib Fractures By Thomas G. Weiser, MD, MPH, Associate Professor, ... Tamponade Hemothorax Injury to the Aorta Pulmonary Contusion Rib Fractures Tension Pneumothorax Traumatic Pneumothorax (See also Introduction to ...

  9. Rib Fractures: To Fix or Not to Fix? An Evidence-Based Algorithm

    Directory of Open Access Journals (Sweden)

    Michael Bemelman

    2017-08-01

    Full Text Available Rib fractures are a common injury resulting from blunt chest trauma. The most important complications associated with rib fractures include death, pneumonia, and the need for mechanical ventilation. The development of new osteosynthesis materials has stimulated increased interest in the surgical treatment of rib fractures. Surgical stabilisation, however, is not needed for every patient with rib fractures or for every patient with flail chest. This paper presents an easy-to-use evidence-based algorithm, developed by the authors, for the treatment of patients with flail chest and isolated rib fractures.

  10. The contribution of rib fractures to chronic pain and disability.

    Science.gov (United States)

    Gordy, Stephanie; Fabricant, Loic; Ham, Bruce; Mullins, Richard; Mayberry, John

    2014-05-01

    The contribution of rib fractures to chronic pain and disability is not well described. Two hundred three patients with rib fractures were followed for 6 months. Chronic pain was assessed using the McGill Pain Questionnaire Pain Rating Index and Present Pain Intensity (PPI) scales. Disability was defined as a decrease in work or functional status. The prevalence of chronic pain was 22% and disability was 53%. Acute PPI predicted chronic pain. Associated injuries, bilateral rib fractures, injury severity score, and number of rib fractures were not predictive of chronic pain. No acute injury characteristics were predictive of disability. Among 89 patients with isolated rib fractures, the prevalence of chronic pain was 28% and of disability was 40%. No injury characteristics predicted chronic pain. Bilateral rib fractures and acute PPI predicted disability. The contribution of rib fractures to chronic pain and disability is significant but unpredictable with conventional injury descriptors. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Chest wall reconstruction with autologas rib grafts in dogs and report of a clinic case.

    Science.gov (United States)

    Tunçözgür, B; Elbeyli, L; Güngör, A; Işik, F; Akay, H

    1999-09-01

    Nowadays, in chest wall reconstruction prosthetic materials are generally used. However, the rejections of prosthetic materials and infections frequently occur in chest wall reconstruction, especially after radiotherapy or resection that is performed due to infections. We used 10 mongrel dogs and performed resections of 8 cm diameter on their chest walls. In the reconstruction of these defects, in five of the subjects, we used two free rib grafts with periosteum to be resected from the contralateral side and in other five subjects, we used free rib grafts without periosteum. After this experimental study, sternal resection was performed in a 24-year-old man because of sternal osteomyelitis. First to obtain rib grafts with periosteum, partial resection was performed to 5th, 7th, and 9th ribs of the lateral left side. After, total sternal resection, end to end anastomosis was performed to the 2nd, 3rd, 4th and 5th anterior ends of the ribs. Autogeneous rib grafts were found to be enough to provide chest wall stabilization. The contralateral autogeneous free rib grafts can successfully be used in reconstruction of wide chest wall defects. This method is found to be effective and sufficient to prevent infection, rejection and to provide stabilization.

  12. Scoliosis secondary to an unusual rib lesion.

    LENUS (Irish Health Repository)

    Burke, N G

    2012-04-01

    Tumours of the chest wall are uncommon and are usually malignant. A bone haemangioma is a rare benign vascular neoplasm, which more commonly occurs in middle-aged patients. We present the case of a scoliosis caused by a rib haemangioma in an adolescent male. Other causes of scoliosis secondary to rib lesions are discussed.

  13. Changes in sapwood permeability and anatomy with tree age and height in the broad-leaved evergreen species Eucalyptus regnans.

    Science.gov (United States)

    England, Jacqueline R; Attiwill, Peter M

    2007-08-01

    Increases in plant size and structural complexity with increasing age have important implications for water flow through trees. Water supply to the crown is influenced by both the cross-sectional area and the permeability of sapwood. It has been hypothesized that hydraulic conductivity within sapwood increases with age. We investigated changes in sapwood permeability (k) and anatomy with tree age and height in the broad-leaved evergreen species Eucalyptus regnans F. Muell. Sapwood was sampled at breast height from trees ranging from 8 to 240 years old, and at three height positions on the main stem of 8-year-old trees. Variation in k was not significant among sampling height positions in young trees. However, k at breast height increased with tree age. This was related to increases in both vessel frequency and vessel diameter, resulting in a greater proportion of sapwood being occupied by vessel lumina. Sapwood hydraulic conductivity (the product of k and sapwood area) also increased with increasing tree age. However, at the stand level, there was a decrease in forest sapwood hydraulic conductivity with increasing stand age, because of a decrease in the number of trees per hectare. Across all ages, there were significant relationships between k and anatomy, with individual anatomical characteristics explaining 33-62% of the variation in k. There was also strong agreement between measured k and permeability predicted by the Hagen-Poiseuille equation. The results support the hypothesis of an increase in sapwood permeability at breast height with age. Further measurements are required to confirm this result at other height positions in older trees. The significance of tree-level changes in sapwood permeability for stand-level water relations is discussed.

  14. Epidemiology of rib fractures in older men: Osteoporotic Fractures in Men (MrOS) prospective cohort study.

    Science.gov (United States)

    Barrett-Connor, Elizabeth; Nielson, Carrie M; Orwoll, Eric; Bauer, Douglas C; Cauley, Jane A

    2010-03-15

    To study the causes and consequences of radiologically confirmed rib fractures (seldom considered in the context of osteoporosis) in community dwelling older men. Prospective cohort study (Osteoporotic Fractures in Men (MrOS) Study). 5995 men aged 65 or over recruited in 2000-2 from six US sites; 99% answered mailed questionnaires about falls and fractures every four months for a mean 6.2 (SD 1.3) year follow-up. New fractures validated by radiology reports; multivariate Cox proportional hazard ratios were used to evaluate factors independently associated with time to incident rib fracture; associations between baseline rib fracture and incident hip and wrist fracture were also evaluated. The incidence of rib fracture was 3.5/1000 person years, and 24% (126/522) of all incident non-spine fractures were rib fractures. Nearly half of new rib fractures (48%; n=61) followed falling from standing height or lower. Independent risk factors for an incident rib fracture were age 80 or above, low bone density, difficulty with instrumental activities of daily living, and a baseline history of rib/chest fracture. Men with a history of rib/chest fracture had at least a twofold increased risk of an incident rib fracture (adjusted hazard ratio 2.71, 95% confidence interval 1.86 to 3.95), hip fracture (2.05, 1.33 to 3.15), and wrist fracture (2.06, 1.14 to 3.70). Only 14/82 of men reported being treated with bone specific drugs after their incident rib fracture. Rib fracture, the most common incident clinical fracture in men, was associated with classic risk markers for osteoporosis, including old age, low hip bone mineral density, and history of fracture. A history of rib fracture predicted a more than twofold increased risk of future fracture of the rib, hip, or wrist, independent of bone density and other covariates. Rib fractures should be considered to be osteoporotic fractures in the evaluation of older men for treatment to prevent future fracture.

  15. [Internal fixation treatment of multiple rib fractures with absorbable rib-connecting-pins under epidural anesthesia].

    Science.gov (United States)

    Liu, Jinliang; Li, Keyao; Ju, Zhenlong; Bai, Yan

    2011-03-01

    To study the indications, methods and experience of absorbable rib-connecting-pins fixation in the treatment of multiple rib fractures. 52 cases with multiple rib fractures were performed internal fixation with absorbable rib-connecting-pins under epidural anesthesia. All cases were followed up for 1 to 12 months, with an average of 5 months. All fractures were achieved healing in 3 to 6 months after the operation and were not found chest wall deformity. Absorbable rib-connecting-pins fixation is a simple and effective method and worthies recommending to perform operation for the appropriate cases with multiple rib fractures.

  16. The transverse diameter of the chest on routine radiographs reliably estimates gestational age and weight in premature infants

    Energy Technology Data Exchange (ETDEWEB)

    Dietz, Kelly R. [University of Minnesota, Department of Radiology, Minneapolis, MN (United States); Zhang, Lei [University of Minnesota, Biostatistical Design and Analysis Center, Minneapolis, MN (United States); Seidel, Frank G. [Lucile Packard Children' s Hospital, Department of Radiology, Stanford, CA (United States)

    2015-08-15

    Prior to digital radiography it was possible for a radiologist to easily estimate the size of a patient on an analog film. Because variable magnification may be applied at the time of processing an image, it is now more difficult to visually estimate an infant's size on the monitor. Since gestational age and weight significantly impact the differential diagnosis of neonatal diseases and determine the expected size of kidneys or appearance of the brain by MRI or US, this information is useful to a pediatric radiologist. Although this information may be present in the electronic medical record, it is frequently not readily available to the pediatric radiologist at the time of image interpretation. To determine if there was a correlation between gestational age and weight of a premature infant with their transverse chest diameter (rib to rib) on admission chest radiographs. This retrospective study was approved by the institutional review board, which waived informed consent. The maximum transverse chest diameter outer rib to outer rib was measured on admission portable chest radiographs of 464 patients admitted to the neonatal intensive care unit (NICU) during the 2010 calendar year. Regression analysis was used to investigate the association between chest diameter and gestational age/birth weight. Quadratic term of chest diameter was used in the regression model. Chest diameter was statistically significantly associated with both gestational age (P < 0.0001) and birth weight (P < 0.0001). An infant's gestational age and birth weight can be reliably estimated by comparing a simple measurement of the transverse chest diameter on digital chest radiograph with the tables and graphs in our study. (orig.)

  17. Evaluation of the Barr & Stroud FP15 and Criterion 400 laser dendrometers for measuring upper stem diameters and heights

    Science.gov (United States)

    Michael S. Williams; Kenneth L. Cormier; Ronald G. Briggs; Donald L. Martinez

    1999-01-01

    Calibrated Barr & Stroud FP15 and Criterion 400 laser dendrometers were tested for reliability in measuring upper stem diameters and heights under typical field conditions. Data were collected in the Black Hills National Forest, which covers parts of South Dakota and Wyoming in the United States. Mixed effects models were employed to account for differences between...

  18. Spontaneous rib fractures.

    Science.gov (United States)

    Katrancioglu, Ozgur; Akkas, Yucel; Arslan, Sulhattin; Sahin, Ekber

    2015-07-01

    Other than trauma, rib fracture can occur spontaneously due to a severe cough or sneeze. In this study, patients with spontaneous rib fractures were analyzed according to age, sex, underlying pathology, treatment, and complications. Twelve patients who presented between February 2009 and February 2011 with spontaneous rib fracture were reviewed retrospectively. The patients' data were evaluated according to anamnesis, physical examination, and chest radiographs. The ages of the patients ranged from 34 to 77 years (mean 55.91 ± 12.20 years), and 7 (58.4%) were male. All patients had severe cough and chest pain. The fractures were most frequently between 4th and 9th ribs; multiple rib fractures were detected in 5 (41.7%) patients. Eight (66.7%) patients had chronic obstructive pulmonary disease, 2 (16.7%) had bronchial asthma, and 2 (16.7%) had osteoporosis. Bone densitometry revealed a high risk of bone fracture in all patients. Patients with chronic obstructive pulmonary disease or bronchial asthma had been treated with high-dose steroids for over a year. Spontaneous rib fracture due to severe cough may occur in patients with osteoporosis, chronic obstructive pulmonary disease, or bronchial asthma, receiving long-term steroid therapy. If these patients have severe chest pain, chest radiography should be performed to check for bone lesions. © The Author(s) 2015.

  19. Modeling and Simulation of Turbulent Flows through a Solar Air Heater Having Square-Sectioned Transverse Rib Roughness on the Absorber Plate

    Directory of Open Access Journals (Sweden)

    Anil Singh Yadav

    2013-01-01

    Full Text Available Solar air heater is a type of heat exchanger which transforms solar radiation into heat energy. The thermal performance of conventional solar air heater has been found to be poor because of the low convective heat transfer coefficient from the absorber plate to the air. Use of artificial roughness on a surface is an effective technique to enhance the rate of heat transfer. A CFD-based investigation of turbulent flow through a solar air heater roughened with square-sectioned transverse rib roughness has been performed. Three different values of rib-pitch (P and rib-height (e have been taken such that the relative roughness pitch (P/e=14.29 remains constant. The relative roughness height, e/D, varies from 0.021 to 0.06, and the Reynolds number, Re, varies from 3800 to 18,000. The results predicted by CFD show that the average heat transfer, average flow friction, and thermohydraulic performance parameter are strongly dependent on the relative roughness height. A maximum value of thermohydraulic performance parameter has been found to be 1.8 for the range of parameters investigated. Comparisons with previously published work have been performed and found to be in excellent agreement.

  20. Modeling and simulation of turbulent flows through a solar air heater having square-sectioned transverse rib roughness on the absorber plate.

    Science.gov (United States)

    Yadav, Anil Singh; Bhagoria, J L

    2013-01-01

    Solar air heater is a type of heat exchanger which transforms solar radiation into heat energy. The thermal performance of conventional solar air heater has been found to be poor because of the low convective heat transfer coefficient from the absorber plate to the air. Use of artificial roughness on a surface is an effective technique to enhance the rate of heat transfer. A CFD-based investigation of turbulent flow through a solar air heater roughened with square-sectioned transverse rib roughness has been performed. Three different values of rib-pitch (P) and rib-height (e) have been taken such that the relative roughness pitch (P/e = 14.29) remains constant. The relative roughness height, e/D, varies from 0.021 to 0.06, and the Reynolds number, Re, varies from 3800 to 18,000. The results predicted by CFD show that the average heat transfer, average flow friction, and thermohydraulic performance parameter are strongly dependent on the relative roughness height. A maximum value of thermohydraulic performance parameter has been found to be 1.8 for the range of parameters investigated. Comparisons with previously published work have been performed and found to be in excellent agreement.

  1. New Hybrid Algorithms for Estimating Tree Stem Diameters at Breast Height Using a Two Dimensional Terrestrial Laser Scanner

    Directory of Open Access Journals (Sweden)

    Jianlei Kong

    2015-07-01

    Full Text Available In this paper, a new algorithm to improve the accuracy of estimating diameter at breast height (DBH for tree trunks in forest areas is proposed. First, the information is collected by a two-dimensional terrestrial laser scanner (2DTLS, which emits laser pulses to generate a point cloud. After extraction and filtration, the laser point clusters of the trunks are obtained, which are optimized by an arithmetic means method. Then, an algebraic circle fitting algorithm in polar form is non-linearly optimized by the Levenberg-Marquardt method to form a new hybrid algorithm, which is used to acquire the diameters and positions of the trees. Compared with previous works, this proposed method improves the accuracy of diameter estimation of trees significantly and effectively reduces the calculation time. Moreover, the experimental results indicate that this method is stable and suitable for the most challenging conditions, which has practical significance in improving the operating efficiency of forest harvester and reducing the risk of causing accidents.

  2. Rib fracture - aftercare

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000539.htm Rib fracture - aftercare To use the sharing features on this page, please enable JavaScript. A rib fracture is a crack or break in one or ...

  3. The effect of channel height on bubble nucleation in superhydrophobic microchannels due to subcritical heating

    Science.gov (United States)

    Cowley, Adam; Maynes, Daniel; Crockett, Julie; Iverson, Brian

    2017-11-01

    This work experimentally investigates the effects of heating on laminar flow in high aspect ratio superhydrophobic (SH) microchannels. When water that is saturated with dissolved air is used, the unwetted cavities of the SH surfaces act as nucleation sites and air effervesces out of solution onto the surfaces. The microchannels consist of a rib/cavity structured SH surface, that is heated, and a glass surface that is utilized for flow visualization. Two channel heights of nominally 183 and 366 μm are considered. The friction factor-Reynolds product (fRe) is obtained via pressure drop and volumetric flow rate measurements and the temperature profile along the channel is obtained via thermocouples embedded in an aluminum block below the SH surface. Five surface types/configurations are investigated: smooth hydrophilic, smooth hydrophobic, SH with ribs perpendicular to the flow, SH with ribs parallel to the flow, and SH with both ribs parallel to the flow and sparse ribs perpendicular to the flow. Depending on the surface type/configuration, large bubbles can form and adversely affect fRe and lead to higher temperatures along the channel. Once bubbles grow large enough, they are expelled from the channel. The channel size greatly effects the residence time of the bubbles and consequently fRe and the channel temperature. This research was supported by the National Science Foundation (NSF) (Grant No. CBET-1235881) and the Utah NASA Space Grant Consortium (NASA Grant NNX15A124H).

  4. Ribbing disease

    International Nuclear Information System (INIS)

    Mukkada, Philson J; Franklin, Teenu; Rajeswaran, Rangasami; Joseph, Santhosh

    2010-01-01

    Ribbing disease is a rare sclerosing dysplasia that involves long tubular bones, especially the tibia and femur. It occurs after puberty and is reported to be more common in women. In this article we describe how Ribbing disease can be differentiated from diseases like Engelmann-Camurati disease, van Buchem disease, Erdheim-Chester disease, osteoid osteoma, chronic osteomyelitis, stress fracture, etc

  5. Atraumatic First Rib Fracture

    OpenAIRE

    Koray Aydogdu

    2014-01-01

    Rib fractures are usually seen after a trauma, while atraumatic spontaneous rib fractures are quite rare. A first rib fracture identified in our 17 years old female patient who had not a history of trauma except lifting a heavy weight was examined in details in terms of the potential complications and followed-up for a long time. We presented our experience on this case with atraumatic first rib fracture that has different views for the etiology in light of the literature.

  6. Experimental investigations on frictional resistance and velocity distribution of rough wall with regularly distributed triangular ribs

    International Nuclear Information System (INIS)

    Motozawa, Masaaki; Ito, Takahiro; Iwamoto, Kaoru; Kawashima, Hideki; Ando, Hirotomo; Senda, Tetsuya; Tsuji, Yoshiyuki; Kawaguchi, Yasuo

    2013-01-01

    Highlights: • Flow over the regularly distributed triangular ribs was investigated. • Simultaneous measurement of flow resistance and velocity profile was performed. • Flow resistance was measured directly and velocity profile was measured by LDV. • Flow resistance was estimated by the information of the velocity field. • Estimated flow resistance has good agreement with the measured flow resistance. -- Abstract: The relationship between the flow resistance of a turbulent flow over triangular ribs regularly distributed on a wall surface and the velocity distribution around the ribs was investigated experimentally. A concentric cylinder device composed of an inner test cylinder and an outer cylinder was employed to measure the flow resistance using the torque of the shaft of the inner cylinder and the velocity distribution of the flow around a rib by laser Doppler velocimetry (LDV) simultaneously. We prepared four inner test cylinders having 4, 8, 12 and 16 triangular ribs on the surface with the same interval between them. Each rib had an isosceles right triangle V-shape and a height of 2 mm. To investigate the relationship between flow resistance and velocity distribution, we estimated the frictional drag and pressure drag acting on the surface of the ribs separately using the velocity distribution. Therefore, we could also estimate the total flow resistance using the velocity distribution. As a result of the experiment, the flow resistance and the attachment point downstream of the rib were shown to depend on the distance between ribs. Moreover, the flow resistance estimated using the velocity distribution had good agreement with the flow resistance measured using the torque of the inner cylinder

  7. Atraumatic First Rib Fracture

    Directory of Open Access Journals (Sweden)

    Koray Aydogdu

    2014-12-01

    Full Text Available Rib fractures are usually seen after a trauma, while atraumatic spontaneous rib fractures are quite rare. A first rib fracture identified in our 17 years old female patient who had not a history of trauma except lifting a heavy weight was examined in details in terms of the potential complications and followed-up for a long time. We presented our experience on this case with atraumatic first rib fracture that has different views for the etiology in light of the literature.

  8. Frictional pressure drop of high pressure steam-water two-phase flow in internally helical ribbed tubes

    International Nuclear Information System (INIS)

    Tingkuan, C.; Xuanzheng, C.

    1987-01-01

    It is well known that the internally helical ribbed tubes are effective in suppressing the dry-out in boiling tubes at high pressures, so they are widely used as furnace water wall tubes in modern large steam power boilers. Design of the boilers requires the data on frictional pressure drop characteristics of the ribbed tubes, but they are not sufficient now. This paper describes the experimental results on the adiabatic frictional pressure drop in both horizontal ribbed tubes with measured mean inside diameter of 11.69 mm and 35.42 mm at high pressure from 10 to 21 MPa, mass flow rate from 350 to 3800 kg/m/sup 2/s and steam quality from 0 to 1 in our high pressure electrically heated water loop. Simultaneously, both smooth tubes under the same conditions for comparison. Based on the tests the correlation for determining the frictional pressure drop of internally ribbed tubes are proposed

  9. Bark thickness related to tree diameter in sugar maple (Acer saccharum Marsh.)

    Science.gov (United States)

    H. Clay Smith

    1969-01-01

    Bark thickness for sugar maple trees in Vermont was found to be related to tree diameter at breast height (d.b.h.). The relationship was positive-as the diameter increased, the bark thickness increased.

  10. Rib fractures and their association With solid organ injury: higher rib fractures have greater significance for solid organ injury screening.

    Science.gov (United States)

    Rostas, Jack W; Lively, Timothy B; Brevard, Sidney B; Simmons, Jon D; Frotan, Mohammad A; Gonzalez, Richard P

    2017-04-01

    The purpose of this study was to identify patients with rib injuries who were at risk for solid organ injury. A retrospective chart review was performed of all blunt trauma patients with rib fractures during the period from July 2007 to July 2012. Data were analyzed for association of rib fractures and solid organ injury. In all, 1,103 rib fracture patients were identified; 142 patients had liver injuries with 109 (77%) associated right rib fractures. Right-sided rib fractures with highest sensitivity for liver injury were middle rib segment (5 to 8) and lower segment (9 to 12) with liver injury sensitivities of 68% and 43%, respectively (P rib fractures. Left middle segment rib fractures and lower segment rib fractures had sensitivities of 80% and 63% for splenic injury, respectively (P Rib fractures higher in the thoracic cage have significant association with solid organ injury. Using rib fractures from middle plus lower segments as indication for abdominal screening will significantly improve rib fracture sensitivity for identification of solid organ injury. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Heat Transfer Augmentation in Gas Turbine Blade Rectangular Passages Using Circular Ribs with Fins

    Directory of Open Access Journals (Sweden)

    Mohammed W. Al-Jibory

    2017-11-01

    Full Text Available In this paper, an experimental system  was designed and built to simulate conditions in the gas turbine blade cooling and run the experimental part. Boundary conditions are: inlet coolant air temperature is 300K with Reynolds numbers (Re=7901 .The surrounding constant hot air temperatures was (673 K.The numerical simulations were done by using software FLUENT version (14.5, in this part, it was presented the effect of using circular ribs having middle fin fitted in rectangular passage channel on fluid flow and heat transfer characteristics.  Ribs used with pitch-rib height of 10, rectangular channel of (30x60 mm cross section, 1.5 mm duct thickness and 0.5 m long. The temperature, velocity distribution contours, cooling air temperature distribution at the duct centerline, the inner wall surface temperature of the duct, and thermal performance factor are presented in this paper. it can be seen that the duct with all ribs with middle fins was the better case which leads to increase the coolant air temperature by (10.22 % and decrease the inner wall temperature by (6.15 % . The coolant air flow velocity seems to be accelerated and decelerated through the channel in the presence of ribs, so it was shown that the thermal performance factor along the duct is larger than 1, this is due to the fact that the ribs create turbulent conditions and increasing thermal surface area, and thus increasing heat transfer coefficient than the smooth channel.

  12. Rib Fracture Diagnosis in the Panscan Era.

    Science.gov (United States)

    Murphy, Charles E; Raja, Ali S; Baumann, Brigitte M; Medak, Anthony J; Langdorf, Mark I; Nishijima, Daniel K; Hendey, Gregory W; Mower, William R; Rodriguez, Robert M

    2017-12-01

    With increased use of chest computed tomography (CT) in trauma evaluation, traditional teachings in regard to rib fracture morbidity and mortality may no longer be accurate. We seek to determine rates of rib fracture observed on chest CT only; admission and mortality of patients with isolated rib fractures, rib fractures observed on CT only, and first or second rib fractures; and first or second rib fracture-associated great vessel injury. We conducted a planned secondary analysis of 2 prospectively enrolled cohorts of the National Emergency X-Radiography Utilization Study chest studies, which evaluated patients with blunt trauma who were older than 14 years and received chest imaging in the emergency department. We defined rib fractures and other thoracic injuries according to CT reports and followed patients through their hospital course to determine outcomes. Of 8,661 patients who had both chest radiograph and chest CT, 2,071 (23.9%) had rib fractures, and rib fractures were observed on chest CT only in 1,368 cases (66.1%). Rib fracture patients had higher admission rates (88.7% versus 45.8%; mean difference 42.9%; 95% confidence interval [CI] 41.4% to 44.4%) and mortality (5.6% versus 2.7%; mean difference 2.9%; 95% CI 1.8% to 4.0%) than patients without rib fracture. The mortality of patients with rib fracture observed on chest CT only was not statistically significantly different from that of patients with fractures also observed on chest radiograph (4.8% versus 5.7%; mean difference -0.9%; 95% CI -3.1% to 1.1%). Patients with first or second rib fractures had significantly higher mortality (7.4% versus 4.1%; mean difference 3.3%; 95% CI 0.2% to 7.1%) and prevalence of concomitant great vessel injury (2.8% versus 0.6%; mean difference 2.2%; 95% CI 0.6% to 4.9%) than patients with fractures of ribs 3 to 12, and the odds ratio of great vessel injury with first or second rib fracture was 4.4 (95% CI 1.8 to 10.4). Under trauma imaging protocols that commonly

  13. Traits and trade-offs in whole-tree hydraulic architecture along the vertical axis of Eucalyptus grandis.

    Science.gov (United States)

    Pfautsch, Sebastian; Aspinwall, Michael J; Drake, John E; Chacon-Doria, Larissa; Langelaan, Rob J A; Tissue, David T; Tjoelker, Mark G; Lens, Frederic

    2018-01-25

    Sapwood traits like vessel diameter and intervessel pit characteristics play key roles in maintaining hydraulic integrity of trees. Surprisingly little is known about how sapwood traits covary with tree height and how such trait-based variation could affect the efficiency of water transport in tall trees. This study presents a detailed analysis of structural and functional traits along the vertical axes of tall Eucalyptus grandis trees. To assess a wide range of anatomical and physiological traits, light and electron microscopy was used, as well as field measurements of tree architecture, water use, stem water potential and leaf area distribution. Strong apical dominance of water transport resulted in increased volumetric water supply per unit leaf area with tree height. This was realized by continued narrowing (from 250 to 20 µm) and an exponential increase in frequency (from 600 to 13 000 cm-2) of vessels towards the apex. The widest vessels were detected at least 4 m above the stem base, where they were associated with the thickest intervessel pit membranes. In addition, this study established the lower limit of pit membrane thickness in tall E. grandis at ~375 nm. This minimum thickness was maintained over a large distance in the upper stem, where vessel diameters continued to narrow. The analyses of xylem ultrastructure revealed complex, synchronized trait covariation and trade-offs with increasing height in E. grandis. Anatomical traits related to xylem vessels and those related to architecture of pit membranes were found to increase efficiency and apical dominance of water transport. This study underlines the importance of studying tree hydraulic functioning at organismal scale. Results presented here will improve understanding height-dependent structure-function patterns in tall trees. © The Author(s) 2018. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Bifid rib: A rare anomaly

    Directory of Open Access Journals (Sweden)

    Mythili Krishnan Rathinasabapathi

    2015-01-01

    Full Text Available A case of the bifid rib was found during routine bone study. The distal part of the osseous rib bifurcated into two divisions with an angle of 60°. Both divisions had their own costal cartilage. Bifid rib is a congenital abnormality of the rib cage and usually asymptomatic, often discovered incidentally on chest X-ray. Effects of this neuroskeletal anomaly can include respiratory difficulties and neurological limitations.

  15. Segmentation of ribs in digital chest radiographs

    Science.gov (United States)

    Cong, Lin; Guo, Wei; Li, Qiang

    2016-03-01

    Ribs and clavicles in posterior-anterior (PA) digital chest radiographs often overlap with lung abnormalities such as nodules, and cause missing of these abnormalities, it is therefore necessary to remove or reduce the ribs in chest radiographs. The purpose of this study was to develop a fully automated algorithm to segment ribs within lung area in digital radiography (DR) for removal of the ribs. The rib segmentation algorithm consists of three steps. Firstly, a radiograph was pre-processed for contrast adjustment and noise removal; second, generalized Hough transform was employed to localize the lower boundary of the ribs. In the third step, a novel bilateral dynamic programming algorithm was used to accurately segment the upper and lower boundaries of ribs simultaneously. The width of the ribs and the smoothness of the rib boundaries were incorporated in the cost function of the bilateral dynamic programming for obtaining consistent results for the upper and lower boundaries. Our database consisted of 93 DR images, including, respectively, 23 and 70 images acquired with a DR system from Shanghai United-Imaging Healthcare Co. and from GE Healthcare Co. The rib localization algorithm achieved a sensitivity of 98.2% with 0.1 false positives per image. The accuracy of the detected ribs was further evaluated subjectively in 3 levels: "1", good; "2", acceptable; "3", poor. The percentages of good, acceptable, and poor segmentation results were 91.1%, 7.2%, and 1.7%, respectively. Our algorithm can obtain good segmentation results for ribs in chest radiography and would be useful for rib reduction in our future study.

  16. Estimating Tree Height and Diameter at Breast Height (DBH from Digital Surface Models and Orthophotos Obtained with an Unmanned Aerial System for a Japanese Cypress (Chamaecyparis obtusa Forest

    Directory of Open Access Journals (Sweden)

    Kotaro Iizuka

    2017-12-01

    Full Text Available Methods for accurately measuring biophysical parameters are a key component for quantitative evaluation regarding to various forest applications. Conventional in situ measurements of these parameters take time and expense, encountering difficultness at locations with heterogeneous microtopography. To obtain precise biophysical data in such situations, we deployed an unmanned aerial system (UAS multirotor drone in a cypress forest in a mountainous area of Japan. The structure from motion (SfM method was used to construct a three-dimensional (3D model of the forest (tree structures from aerial photos. Tree height was estimated from the 3D model and compared to in situ ground data. We also analyzed the relationships between a biophysical parameter, diameter at breast height (DBH, of individual trees with canopy width and area measured from orthorectified images. Despite the constraints of ground exposure in a highly dense forest area, tree height was estimated at an accuracy of root mean square error = 1.712 m for observed tree heights ranging from 16 to 24 m. DBH was highly correlated with canopy width (R2 = 0.7786 and canopy area (R2 = 0.7923, where DBH ranged from 11 to 58 cm. The results of estimating forest parameters indicate that drone-based remote-sensing methods can be utilized to accurately analyze the spatial extent of forest structures.

  17. Approximation of the breast height diameter distribution of two-cohort stands by mixture models III Kernel density estimators vs mixture models

    Science.gov (United States)

    Rafal Podlaski; Francis A. Roesch

    2014-01-01

    Two-component mixtures of either the Weibull distribution or the gamma distribution and the kernel density estimator were used for describing the diameter at breast height (dbh) empirical distributions of two-cohort stands. The data consisted of study plots from the Å wietokrzyski National Park (central Poland) and areas close to and including the North Carolina section...

  18. Height - Diameter predictive equations for Rubber (Hevea ...

    African Journals Online (AJOL)

    BUKOLA

    They proffer logistic data for modeling and futuristic prediction for sustainable forest management. Diameter is one of the most ... in various quantitative estimation following the intricacy of time, availability of modern equipments .... growth functions. This trend is shown in Figure 1 where the prediction equations are plotted.

  19. Rib fracture after stereotactic radiotherapy for primary lung cancer: prevalence, degree of clinical symptoms, and risk factors

    International Nuclear Information System (INIS)

    Nambu, Atsushi; Marino, Kan; Koshiishi, Tsuyota; Sawada, Eiichi; Araki, Tsutomu; Onishi, Hiroshi; Aoki, Shinichi; Tominaga, Licht; Kuriyama, Kengo; Araya, Masayuki; Saito, Ryoh; Maehata, Yoshiyasu; Komiyama, Takafumi

    2013-01-01

    As stereotactic body radiotherapy (SBRT) is a highly dose-dense radiotherapy, adverse events of neighboring normal tissues are a major concern. This study thus aimed to clarify the frequency and degree of clinical symptoms in patients with rib fractures after SBRT for primary lung cancer and to reveal risk factors for rib fracture. Appropriate α/β ratios for discriminating between fracture and non-fracture groups were also investigated. Between November 2001 and April 2009, 177 patients who had undergone SBRT were evaluated for clinical symptoms and underwent follow-up thin-section computed tomography (CT). The time of rib fracture appearance was also assessed. Cox proportional hazard modeling was performed to identify risk factors for rib fracture, using independent variables of age, sex, maximum tumor diameter, radiotherapeutic method and tumor-chest wall distance. Dosimetric details were analyzed for 26 patients with and 22 randomly-sampled patients without rib fracture. Biologically effective dose (BED) was calculated with a range of α/β ratios (1–10 Gy). Receiver operating characteristics analysis was used to define the most appropriate α/β ratio. Rib fracture was found on follow-up thin-section CT in 41 patients. The frequency of chest wall pain in patients with rib fracture was 34.1% (14/41), and was classified as Grade 1 or 2. Significant risk factors for rib fracture were smaller tumor-chest wall distance and female sex. Area under the curve was maximal for BED at an α/β ratio of 8 Gy. Rib fracture is frequently seen on CT after SBRT for lung cancer. Small tumor-chest wall distance and female sex are risk factors for rib fracture. However, clinical symptoms are infrequent and generally mild. When using BED analysis, an α/β ratio of 8 Gy appears most effective for discriminating between fracture and non-fracture patients

  20. Rib fracture after stereotactic radiotherapy for primary lung cancer: prevalence, degree of clinical symptoms, and risk factors

    Directory of Open Access Journals (Sweden)

    Nambu Atsushi

    2013-02-01

    Full Text Available Abstract Background As stereotactic body radiotherapy (SBRT is a highly dose-dense radiotherapy, adverse events of neighboring normal tissues are a major concern. This study thus aimed to clarify the frequency and degree of clinical symptoms in patients with rib fractures after SBRT for primary lung cancer and to reveal risk factors for rib fracture. Appropriate α/β ratios for discriminating between fracture and non-fracture groups were also investigated. Methods Between November 2001 and April 2009, 177 patients who had undergone SBRT were evaluated for clinical symptoms and underwent follow-up thin-section computed tomography (CT. The time of rib fracture appearance was also assessed. Cox proportional hazard modeling was performed to identify risk factors for rib fracture, using independent variables of age, sex, maximum tumor diameter, radiotherapeutic method and tumor-chest wall distance. Dosimetric details were analyzed for 26 patients with and 22 randomly-sampled patients without rib fracture. Biologically effective dose (BED was calculated with a range of α/β ratios (1–10 Gy. Receiver operating characteristics analysis was used to define the most appropriate α/β ratio. Results Rib fracture was found on follow-up thin-section CT in 41 patients. The frequency of chest wall pain in patients with rib fracture was 34.1% (14/41, and was classified as Grade 1 or 2. Significant risk factors for rib fracture were smaller tumor-chest wall distance and female sex. Area under the curve was maximal for BED at an α/β ratio of 8 Gy. Conclusions Rib fracture is frequently seen on CT after SBRT for lung cancer. Small tumor-chest wall distance and female sex are risk factors for rib fracture. However, clinical symptoms are infrequent and generally mild. When using BED analysis, an α/β ratio of 8 Gy appears most effective for discriminating between fracture and non-fracture patients.

  1. Rib fracture after stereotactic radiotherapy for primary lung cancer: prevalence, degree of clinical symptoms, and risk factors

    Science.gov (United States)

    2013-01-01

    Background As stereotactic body radiotherapy (SBRT) is a highly dose-dense radiotherapy, adverse events of neighboring normal tissues are a major concern. This study thus aimed to clarify the frequency and degree of clinical symptoms in patients with rib fractures after SBRT for primary lung cancer and to reveal risk factors for rib fracture. Appropriate α/β ratios for discriminating between fracture and non-fracture groups were also investigated. Methods Between November 2001 and April 2009, 177 patients who had undergone SBRT were evaluated for clinical symptoms and underwent follow-up thin-section computed tomography (CT). The time of rib fracture appearance was also assessed. Cox proportional hazard modeling was performed to identify risk factors for rib fracture, using independent variables of age, sex, maximum tumor diameter, radiotherapeutic method and tumor-chest wall distance. Dosimetric details were analyzed for 26 patients with and 22 randomly-sampled patients without rib fracture. Biologically effective dose (BED) was calculated with a range of α/β ratios (1–10 Gy). Receiver operating characteristics analysis was used to define the most appropriate α/β ratio. Results Rib fracture was found on follow-up thin-section CT in 41 patients. The frequency of chest wall pain in patients with rib fracture was 34.1% (14/41), and was classified as Grade 1 or 2. Significant risk factors for rib fracture were smaller tumor-chest wall distance and female sex. Area under the curve was maximal for BED at an α/β ratio of 8 Gy. Conclusions Rib fracture is frequently seen on CT after SBRT for lung cancer. Small tumor-chest wall distance and female sex are risk factors for rib fracture. However, clinical symptoms are infrequent and generally mild. When using BED analysis, an α/β ratio of 8 Gy appears most effective for discriminating between fracture and non-fracture patients. PMID:23391264

  2. Rib fracture after stereotactic radiotherapy for primary lung cancer: prevalence, degree of clinical symptoms, and risk factors.

    Science.gov (United States)

    Nambu, Atsushi; Onishi, Hiroshi; Aoki, Shinichi; Tominaga, Licht; Kuriyama, Kengo; Araya, Masayuki; Saito, Ryoh; Maehata, Yoshiyasu; Komiyama, Takafumi; Marino, Kan; Koshiishi, Tsuyota; Sawada, Eiichi; Araki, Tsutomu

    2013-02-07

    As stereotactic body radiotherapy (SBRT) is a highly dose-dense radiotherapy, adverse events of neighboring normal tissues are a major concern. This study thus aimed to clarify the frequency and degree of clinical symptoms in patients with rib fractures after SBRT for primary lung cancer and to reveal risk factors for rib fracture. Appropriate α/β ratios for discriminating between fracture and non-fracture groups were also investigated. Between November 2001 and April 2009, 177 patients who had undergone SBRT were evaluated for clinical symptoms and underwent follow-up thin-section computed tomography (CT). The time of rib fracture appearance was also assessed. Cox proportional hazard modeling was performed to identify risk factors for rib fracture, using independent variables of age, sex, maximum tumor diameter, radiotherapeutic method and tumor-chest wall distance. Dosimetric details were analyzed for 26 patients with and 22 randomly-sampled patients without rib fracture. Biologically effective dose (BED) was calculated with a range of α/β ratios (1-10 Gy). Receiver operating characteristics analysis was used to define the most appropriate α/β ratio. Rib fracture was found on follow-up thin-section CT in 41 patients. The frequency of chest wall pain in patients with rib fracture was 34.1% (14/41), and was classified as Grade 1 or 2. Significant risk factors for rib fracture were smaller tumor-chest wall distance and female sex. Area under the curve was maximal for BED at an α/β ratio of 8 Gy. Rib fracture is frequently seen on CT after SBRT for lung cancer. Small tumor-chest wall distance and female sex are risk factors for rib fracture. However, clinical symptoms are infrequent and generally mild. When using BED analysis, an α/β ratio of 8 Gy appears most effective for discriminating between fracture and non-fracture patients.

  3. Accessory caudal axial and pelvic ribs

    International Nuclear Information System (INIS)

    Bohutova, J.; Kolar, J.; Vitovec, J.; Vyhnanek, L.

    1980-01-01

    Accessory caudal ribs are reported as an extremely curious anomaly in five patients. Once the fracture of this rib was a source of pains after injury. The different shapes of the ribs are documented in this clinical survey which is the most extensive in the present literature. Anomalous ribs arise due to inappropriate segmentation during the embryonal development of the axial skeleton. (orig.) [de

  4. Comparison of Postoperative Pain Relief by Intercostal Block Between Pre-rib Harvest and Post-rib Harvest Groups

    International Nuclear Information System (INIS)

    Bashir, M. M.; Shahzad, M. A.; Yousaf, M. N.; Khan, B. A.; Khan, F. A.

    2014-01-01

    Objective: To compare intercostal nerve block before and after rib harvest in terms of mean postoperative pain score and mean postoperative tramadol usage. Study Design: Randomized controlled trial. Place and Duration of Study: Department of Plastic Surgery, Mayo Hospital, KEMU, Lahore, from January 2011 to July 2012. Methodology: Patients (n = 120) of either gender with ASA class-I and II requiring autogenous costal cartilage graft were inducted. Patients having history of local anaesthetic hypersensitivity and age 60 years were excluded. Subjects were randomly assigned to pre-rib harvest (group-1) and post-rib harvest (group-2). Local anaesthetic mixture was prepared by adding 10 milliliters 2% lidocaine to 10 milliliters 0.5% bupivacaine to obtain a total 20 ml solution. Group-1 received local anaesthetic infiltration along the proposed incision lines and intercostals block before the rib harvest. Group-2 received the infiltration and block after rib harvest. Postoperative consumption of tramadol and pain scores were measured at 6 and 12 hours postoperatively using VAS. Results: Mean age was 31.43 A +- 10.78 years. The mean pain scores at 6 hours postoperatively were 1.033 A +- 0.609 and 2.4667 A +- 0.812 in pre-rib harvest and post-rib harvest groups respectively (p < 0.0001). The mean pain scores at 12 hours postoperatively were 1.45 A +- 0.565 and 3.65 A +- 0.633 in pre-rib harvest and post-rib harvest groups respectively (p < 0.0001). The mean tramadol used postoperatively in first 24 hours was 169 A +- 29.24 mg and 255 A +- 17.70 mg in prerib harvest and post-rib harvest groups respectively (p < 0.0001). Conclusion: Intercostal block administered before rib harvest as preemptive strategy result in decreased postoperative pain scores and narcotic use. (author)

  5. Anatomical variation of human thoracic rib in dry bone.

    Directory of Open Access Journals (Sweden)

    Dr. Nalini Konkani

    2017-12-01

    Full Text Available Introduction: The Ribs are essential structure of osseous thorax and provide information that aids in the interpretation of radiologic images. The purpose of this study to investigate variations in thoracic rib and its morphological & clinical importance. So, In present study attempted to find out additional intercostal spaces due to bifurcation of ribs, less intercostal space due to fusion of ribs, variation of the normal ribs like, gap in the rib, fusion of one rib to another at a shaft of rib. Congenital abnormalities of the ribs are usually asymptomatic, often discovered incidentally on chest X-ray. Effects of this neuroskeletal anomaly can include respiratory difficulties and neurological limitations.Material & Method: The study was carried out in Bone Store of Department of Anatomy, B. J. Medical College, Ahmedabad, Gujarat. Study was carried out on 500 human dried ribs. And the variations in the ribs are studied. We got variation in the human ribs and studied. Result : Variations were seen like out of 500 ribs, Bifid rib having two ends 9(1.8%, rib having bifid space 2(0.4%, fusion rib at the level of shaft 1(0.2%, fusion of first rib and second rib 1(0.2%,first rib having two ends 1(0.2%. Conclusion: Bifid rib is an anatomical variant where the sternal end of the rib is cleaved into two. So we can rule out mesodermal abnormalities, parenchymal lung disease, chest wall tumor or costal fracture.

  6. Anatomically contoured plates for fixation of rib fractures.

    Science.gov (United States)

    Bottlang, Michael; Helzel, Inga; Long, William B; Madey, Steven

    2010-03-01

    : Intraoperative contouring of long bridging plates for stabilization of flail chest injuries is difficult and time consuming. This study implemented for the first time biometric parameters to derive anatomically contoured rib plates. These plates were tested on a range of cadaveric ribs to quantify plate fit and to extract a best-fit plating configuration. : Three left and three right rib plates were designed, which accounted for anatomic parameters required when conforming a plate to the rib surface. The length lP over which each plate could trace the rib surface was evaluated on 109 cadaveric ribs. For each rib level 3-9, the plate design with the highest lP value was extracted to determine a best-fit plating configuration. Furthermore, the characteristic twist of rib surfaces was measured on 49 ribs to determine the surface congruency of anatomic plates with a constant twist. : The tracing length lP of the best-fit plating configuration ranged from 12.5 cm to 14.7 cm for ribs 3-9. The corresponding range for standard plates was 7.1-13.7 cm. The average twist of ribs over 8-cm, 12-cm, and 16-cm segments was 8.3 degrees, 20.6 degrees, and 32.7 degrees, respectively. The constant twist of anatomic rib plates was not significantly different from the average rib twist. : A small set of anatomic rib plates can minimize the need for intraoperative plate contouring for fixation of ribs 3-9. Anatomic rib plates can therefore reduce the time and complexity of flail chest stabilization and facilitate spanning of flail segments with long plates.

  7. Design and thermal/hydraulic characteristics of the ITER-FEAT vacuum vessel

    International Nuclear Information System (INIS)

    Onozuka, M.; Ioki, K.; Sannazzaro, G.; Utin, Y.; Yoshimura, H.

    2001-01-01

    Recent progress in structural design and thermal and hydraulic assessment of the vacuum vessel (VV) for ITER-FEAT is presented. Because of the direct attachment of the blanket modules to the VV, the module support structures are recessed into the double-wall VV, partially replacing the stiffening ribs between the VV shells to simplify the VV structure. Structural integrity of the VV is provided by the ribs and the module support structures with local reinforcement ribs. The detailed structural design of the VV taking account of the fabricability and code/standard acceptance is presented. Cost reduction of the VV fabrication using casting or forging is proposed. A high heat removal capability is required for the VV cooling to keep the thermal stress below the allowable. It is expected that natural thermo-gravitational convection due to the heat flux from the vessel wall to the water will enhance heat transfer characteristics even in the low flow velocity region

  8. Design and thermal/hydraulic characteristics of the ITER-FEAT vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    Onozuka, M. E-mail: onozukm@itereu.de; Ioki, K.; Sannazzaro, G.; Utin, Y.; Yoshimura, H

    2001-11-01

    Recent progress in structural design and thermal and hydraulic assessment of the vacuum vessel (VV) for ITER-FEAT is presented. Because of the direct attachment of the blanket modules to the VV, the module support structures are recessed into the double-wall VV, partially replacing the stiffening ribs between the VV shells to simplify the VV structure. Structural integrity of the VV is provided by the ribs and the module support structures with local reinforcement ribs. The detailed structural design of the VV taking account of the fabricability and code/standard acceptance is presented. Cost reduction of the VV fabrication using casting or forging is proposed. A high heat removal capability is required for the VV cooling to keep the thermal stress below the allowable. It is expected that natural thermo-gravitational convection due to the heat flux from the vessel wall to the water will enhance heat transfer characteristics even in the low flow velocity region.

  9. Flow field optimization for proton exchange membrane fuel cells with varying channel heights and widths

    International Nuclear Information System (INIS)

    Wang Xiaodong; Huang Yuxian; Cheng, C.-H.; Jang, J.-Y.; Lee, D.-J.; Yan, W.-M.; Su Ay

    2009-01-01

    The optimal cathode flow field design of a single serpentine proton exchange membrane fuel cell is obtained by adopting a combined optimization procedure including a simplified conjugate-gradient method (SCGM) and a completely three-dimensional, two-phase, non-isothermal fuel cell model. The cell output power density P cell is the objective function to be maximized with channel heights, H 1 -H 5 , and channel widths, W 2 -W 5 as search variables. The optimal design has tapered channels 1, 3 and 4, and diverging channels 2 and 5, producing 22.51% increment compared with the basic design with all heights and widths setting as 1 mm. Reduced channel heights of channels 2-4 significantly enhance sub-rib convection to effectively transport oxygen to and liquid water out of diffusion layer. The final diverging channel prevents significant leakage of fuel to outlet via sub-rib convection from channel 4. Near-optimal design without huge loss in cell performance but is easily manufactured is discussed.

  10. Turbulent flow in a ribbed channel: Flow structures in the vicinity of a rib

    DEFF Research Database (Denmark)

    Wang, Lei; Salewski, Mirko; Sundén, Bengt

    2010-01-01

    PIV measurements are performed in a channel with periodic ribs on one wall. The emphasis of this study is to investigate the flow structures in the vicinity of a rib in terms of mean velocities, Reynolds stresses, probability density functions (PDF), and two-point correlations. The PDF distribution......-based visualization is applied to the separation bubble upstream of the rib. Salient critical points and limit cycles are extracted, which gives clues to the physical processes occurring in the flow....

  11. Numerical simulations of heat transfer in an annular fuel channel with three-dimensional spacer ribs set up periodically under a fully developed turbulent flow

    International Nuclear Information System (INIS)

    Takase, Kazuyuki; Akino, Norio

    1996-06-01

    Thermal-hydraulic characteristics of an annular fuel channel with spacer ribs for high temperature gas-cooled reactors were analyzed numerically by three-dimensional heat transfer computations under a fully developed turbulent flow. The two-equations κ-ε turbulence model was applied to the present turbulent analysis. In particular, the κ-ε turbulence model constants and the turbulent Prandtl number were improved from the previous standard values proposed by Jones and Launder in order to obtain heat transfer predictions with higher accuracy. Consequently, heat transfer coefficients and friction factors in the spacer-ribbed fuel channel were predicted with sufficient accuracy in the range of Reynolds number exceeding 3000. It was clarified quantitatively from the present study that main mechanism for the heat transfer augmentation in the spacer-ribbed fuel channel was combined effects of the turbulence promoter effect by the spacer ribs and the velocity acceleration effect by a reduction in the channel cross-section. (author)

  12. Isolated rib fractures in geriatric patients

    OpenAIRE

    Elmistekawy, Elsayed M.; Hammad, Abd Almohsen M.

    2007-01-01

    Introduction: The goal of this study was to investigate the short-term outcomes in patients older than 60 years with isolated rib fractures and admitted to emergency hospital. Materials and Methods: This study included patients who were 60 years old or more and sustained blunt chest injury and had isolated rib fractures. The following data were obtained from the medical records: age, gender, number of fracture ribs, side of fracture ribs, mechanism and nature of injury, preexisting medical...

  13. Thermal-hydraulic performance of a multiple jet cooling module with a concave dimple array in a helium-cooled divertor

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hyo-Yeon; Kim, Kwang-Yong, E-mail: kykim@inha.ac.kr

    2017-01-15

    A numerical study was performed to evaluate the thermal-hydraulic performance of a finger type cooling module, where multiple jets impinge on the surface with concave dimples, in the divertor of a nuclear fusion reactor. Conjugate heat transfer was analyzed in both the solid and fluid domains using three-dimensional Reynolds-averaged Navier-Stokes equations with the shear stress transport turbulence model. The computational domain consisted of a single fluid domain and three solid domains: tile, thimble, and cartridge. The numerical results for the temperature variation on the tile were validated in comparison with the experimental data. A parametric study was performed with two design variables, the ratios of dimple diameter and dimple height to the nozzle diameter, and two dimple arrays (inline and staggered arrays). The parametric study showed that the heat transfer rate was increased by up to 2.62% by introducing concave dimples, and that the heat transfer and pressure drop performances increased with increasing diameter and height of the dimples for a specified dimple array.

  14. Nineth Rib Syndrome after 10th Rib Resection

    OpenAIRE

    Yu, Hyun Jeong; Jeong, Yu Sub; Lee, Dong Hoon; Yim, Kyoung Hoon

    2016-01-01

    The 12th rib syndrome is a disease that causes pain between the upper abdomen and the lower chest. It is assumed that the impinging on the nerves between the ribs causes pain in the lower chest, upper abdomen, and flank. A 74-year-old female patient visited a pain clinic complaining of pain in her back, and left chest wall at a 7 on the 0-10 Numeric Rating scale (NRS). She had a lateral fixation at T12-L2, 6 years earlier. After the operation, she had multiple osteoporotic compression fractur...

  15. Experimental investigation of the effect of variously-shaped ribs on local heat transfer on the outer wall of the turning portion of a U-channel inside solar air heater

    Science.gov (United States)

    Salameh, Tareq; Alami, Abdul Hai; Sunden, Bengt

    2016-03-01

    In the present work, an experimental investigation of convective heat transfer and pressure drop was carried out for the turning portion of a U-channel where the outer wall was equipped with ribs. The shape of the ribs was varied. The investigation aims to give guidelines for improving the thermo-hydraulic performance of a solar air heater at the turning portion of a U-channel. Both the U-channel and the ribs were made in acrylic material to allow optical access for measuring the surface temperature by using a high-resolution technique based on narrow band thermochromic liquid crystals (TLC R35C5 W) and a CCD camera placed to face the turning portion of the U-channel. The uncertainties were estimated to 5 and 7 % for the Nusselt number and friction factor, respectively. The pressure drop was approximately the same for all the considered shapes of the ribs while the dimpled rib case gave the highest heat transfer coefficient while the grooved rib presented the highest performance index.

  16. ribB and ribBA genes from Acidithiobacillus ferrooxidans: expression levels under different growth conditions and phylogenetic analysis.

    Science.gov (United States)

    Knegt, Fábio H P; Mello, Luciane V; Reis, Fernanda C; Santos, Marcos T; Vicentini, Renato; Ferraz, Lúcio F C; Ottoboni, Laura M M

    2008-01-01

    Acidithiobacillus ferrooxidans is a Gram-negative, chemolithoautotrophic bacterium involved in metal bioleaching. Using the RNA arbitrarily primed polymerase chain reaction (RAP-PCR), we have identified several cDNAs that were differentially expressed when A. ferrooxidans LR was submitted to potassium- and phosphate-limiting conditions. One of these cDNAs showed similarity with ribB. An analysis of the A. ferrooxidans ATCC 23270 genome, made available by The Institute for Genomic Research, showed that the ribB gene was not located in the rib operon, but a ribBA gene was present in this operon instead. The ribBA gene was isolated from A. ferrooxidans LR and expression of both ribB and ribBA was investigated. Transcript levels of both genes were enhanced in cells grown in the absence of K2HPO4, in the presence of zinc and copper sulfate and in different pHs. Transcript levels decreased upon exposure to a temperature higher than the ideal 30 degrees C and at pH 1.2. A comparative genomic analysis using the A. ferrooxidans ATCC 23270 genome revealed similar putative regulatory elements for both genes. Moreover, an RFN element was identified upstream from the ribB gene. Phylogenetic analysis of the distribution of RibB and RibBA in bacteria showed six different combinations. We suggest that the presence of duplicated riboflavin synthesis genes in bacteria must provide their host with some benefit in certain stressful situations.

  17. Study on critical heat flux in narrow rectangular channel with repeated-rib roughness. 1. Experimental facility and preliminary experiments

    International Nuclear Information System (INIS)

    Kinoshita, Hidetaka; Terada, Atsuhiko; Kaminaga, Masanori; Hino, Ryutaro

    2001-10-01

    In the design of a spallation target system, the water cooling system, for example a proton beam window and a safety hull, is used with narrow channels, in order to remove high heat flux and prevent lowering of system performance by absorption of neutron. And in narrow channel, heat transfer enhancement using 2-D rib is considered for reduction the cost of cooling component and decrease inventory of water in the cooling system, that is, decrease of the amount of irradiated water. But few studies on CHF with rib have been carried out. Experimental and analytical studies with rib-roughened test section, in 10:1 ratio of pitch to height, are being carried out in order to clarify the CHF in rib-roughened channel. This paper presents the review of previous researches on heat transfer in channel with rib roughness, overview of the test facility and the preliminary experimental and analytical results. As a result, wall friction factors were about 3 times as large as that of smooth channel, and heat transfer coefficients are about 2 times as large as that of smooth channel. The obtained CHF was as same as previous mechanistic model by Sudo. (author)

  18. Height, shape and anterior-posterior diameter of pituitary gland on magnetic resonance imaging among patients with multiple sclerosis compared to normal individuals.

    Science.gov (United States)

    Saba, Mohammad; Ebrahimi, Hossein Ali; Ahmadi-Pour, Habibeh; Khodadoust, Mohammad

    2017-10-07

    Background: Several studies indicate contribution of hypothalamus-pituitary-adrenal (HPA) axis in multiple sclerosis (MS) disease. This study was designed to determine whether there is an effective difference in pituitary height, shape, and anterior-posterior diameter (APD) between patients with MS and the control group. Methods: In this study, sagittal pituitary height and APD of 134 men and women (64 patients with MS and 70 healthy subjects as control group) were measured by T1 sequence magnetic resonance imaging (MRI). All the subjects were free of sellar or parasellar pathology without a history of surgical intervention or prolactin affecting drugs like bromocriptine and cabergoline or corticosteroid consumption. Results: Mean height of pituitary gland was 6.62 ± 1.43 and 5.78 ± 1.15 mm for patients and the control group, respectively, and the difference between the two groups was statistically significant (P = 0.001). Mean APD was 10.40 ± 1.29 mm for the group of patients and 10.25 ± 1.41 mm for the control group, respectively, without significant differences. 46.9%, 37.5%, and 15.6% of patients had flat, convex, and concave hypophyseal surfaces, respectively. This rate was 50%, 30%, and 20% among the control group, respectively. There was no significant difference between our measurements among patients on whom imaging study was performed at time of disease onset with others. Conclusion: Mean height of pituitary gland among patients with MS was significantly greater than the control group (P = 0.001). So can we consider the same etiology for pituitary hypertrophy among patients with MS as a hypothesis?

  19. Measurement of the heat transfer coefficient in the dimpled channel: effects of dimple arrangement and channel height

    International Nuclear Information System (INIS)

    Shin, So Min; Lee, Ki Seon; Park, Seoung Duck; Kwak, Jae Su

    2009-01-01

    Heat transfer coefficients were measured in a channel with one side dimpled surface. The sphere type dimples were fabricated, and the diameter (D) and the depth of dimple was 16 mm and 4 mm, respectively. Two channel heights of about 0.6D and 1.2D, two dimple configurations were tested. The Reynolds number based on the channel hydraulic diameter was varied from 30000 to 50000. The improved hue detection based transient liquid crystal technique was used in the heat transfer measurement. Heat transfer measurement results showed that high heat transfer was induced downstream of the dimples due to flow reattachment. Due to the flow recirculation on the upstream side in the dimple, the heat transfer coefficient was very low. As the Reynolds increased, the overall heat transfer coefficients also increased. With the same dimple arrangement, the heat transfer coefficients and the thermal performance factors were higher for the lower channel height. As the distance between the dimples became smaller, the overall heat transfer coefficient and the thermal performance factors increased

  20. X-ray diagnosis of rib chondrosarcoma

    International Nuclear Information System (INIS)

    Smakova, M.S.

    1982-01-01

    A study was made on X-ray images of 24 patients, suffering from rib chondrosarcoma with relapses. X-ray symptoms of rib chondrosarcoma, depending on process localization were improved. Chondrosarcoma of rib cartilage is characterized by soft-tissue component with calcareous inclusions or without them. Chondrosarcoma of rib bone is characterized by destruction and soft-tissue component. Chondrosarcoma relapses were localized in soft tissues

  1. Invasive pleural malignant mesothelioma with rib destruction and concurrent osteosarcoma in a dog.

    Science.gov (United States)

    Di Tommaso, Morena; Rocconi, Francesca; Marruchella, Giuseppe; D'Angelo, Anna Rita; Masci, Stefano; Santori, Domenico; Civitella, Carla; Luciani, Alessia; Boari, Andrea

    2015-12-02

    A 7-year-old Dachshund was clinically examined because of a 10-day history of lameness in the left hind limb. On the basis of radiological and cytological findings, an osteosarcoma of the left acetabular region was suspected. The dog underwent a hemipelvectomy and osteosarcoma was diagnosed by subsequent histopathological examination. An immovable subcutaneous mass was noted on the left chest wall during the physical examination and non-septic neutrophilic inflammation was diagnosed by cytology. Forty days later, the dog showed signs of respiratory distress with an in-diameter increase of the subcutaneous mass up to 4 cm. Thoracic radiography and ultrasonography revealed pleural effusion and a lytic process in the fourth left rib. Furthermore, ultrasound examination revealed a mixed echogenic mobile structure with a diameter of around 2 cm floating within the pleural fluid of the left hemithorax close to the pericardium. The dog underwent surgery for an en bloc resection of the subcutaneous mass together with the fourth rib and the parietal pleura. Moreover, the left altered lung lobe, corresponding to the mobile structure detected by ultrasound, was removed. Based on cytological, histopathological, and immunohistochemical examinations, an invasive epithelioid pleural malignant mesothelioma was diagnosed.

  2. Rib Fractures : To Fix or Not to Fix? An Evidence-Based Algorithm

    NARCIS (Netherlands)

    Bemelman, Michael; de Kruijf, M W; van Baal, Mark; Leenen, Luke

    Rib fractures are a common injury resulting from blunt chest trauma. The most important complications associated with rib fractures include death, pneumonia, and the need for mechanical ventilation. The development of new osteosynthesis materials has stimulated increased interest in the surgical

  3. Calculations of shape and stability of menisci in Czochralski growth with tables to determine meniscus heights, maximum heights and capillary constants

    International Nuclear Information System (INIS)

    Uelhoff, W.; Mika, K.

    1975-05-01

    The shape and stability of menisci occurring during Czochralski growth have been studied by means of numerical methods for the case of the free surface. The existence of minimal joining angles is shown, beyond which the growing crystal will separate from the melt. The dependence of the interface height on the joining angle for different crystal diameters was calculated. The maximum stable heights and the corresponding joining angles were determined as a function of crystal diameter. A method for measuring the capillary constant of the melt during Czochralski growth is proposed. The results are compared with known analytical approximations. Limitations of the applications caused by a finite crucible radius or low g values are pointed out. For practical use the following functions have been tabulated: 1) meniscus height in dependence on joining angle and crystal radius, 2) the radius-height-ratio in dependence on radius and angle for the calculation of the capillary constant, 3) the maximum stable height and the corresponding growth angle as a function of crystal radius. (orig.) [de

  4. Fluid dynamics of Ribbed Annuli

    International Nuclear Information System (INIS)

    McCreery, G. E.; Pink, R. J.; Condie, K. G.; McEligot, D. M.

    2003-01-01

    Typical advanced gas-cooled reactor designs use periodic spacer ribs to center rods in circular cooling channels, e.g., as for control rods (General Atomics and others) and fuel rods (HTTR). In contrast to classical studies of axisymmetric annuli, the flow becomes three-dimensional but is typically periodic in the circumferential direction and - in some cases - in the streamwise direction. Fundamental measurements have been obtained for two idealizations of these complex geometries: an annulus with three ribs circumferentially and one with four. Laser Doppler Velocimetry (LDV) was employed with INEEL's unique Matched-Index-of-Refraction (MIR) flow facility to determine the velocity and turbulence fields. The initial experiment was aimed at obtaining benchmark data to test the capabilities of CFD (Computational Fluid Dynamics) codes to handle ribbed annular geometries without the complications of turbulent transport. The Reynolds number was about 1120. These conditions correspond to some stages during a pressurized cooldown (LOFA) event. Power spectral densities were obtained to determine the eddy shedding frequency downstream of the ribs. For the second experiment LDV measurements were obtained in another ribbed-annular model at a higher flow rate. For this nominally turbulent flow, evidence of laminarization appears in the flow converging to pass between ribs. The measurements indicated flow details which could be useful for assessment of CFD codes

  5. Nozzle airfoil having movable nozzle ribs

    Science.gov (United States)

    Yu, Yufeng Phillip; Itzel, Gary Michael

    2002-01-01

    A nozzle vane or airfoil structure is provided in which the nozzle ribs are connected to the side walls of the vane or airfoil in such a way that the ribs provide the requisite mechanical support between the concave side and convex side of the airfoil but are not locked in the radial direction of the assembly, longitudinally of the airfoil. The ribs may be bi-cast onto a preformed airfoil side wall structure or fastened to the airfoil by an interlocking slide connection and/or welding. By attaching the nozzle ribs to the nozzle airfoil metal in such a way that allows play longitudinally of the airfoil, the temperature difference induced radial thermal stresses at the nozzle airfoil/rib joint area are reduced while maintaining proper mechanical support of the nozzle side walls.

  6. Retrospective Analysis of 513 Cases Diagnosed with Rib Fracture Secondary to Blunt Thorax Trauma

    Directory of Open Access Journals (Sweden)

    Serdar Ozkan

    2017-05-01

    Full Text Available Aim: This study aimed to analyze blunt chest trauma cases who were diagnosed with rib fracture and to examine the regional differences likely to appear in trauma cases and treatment approaches. Material and Method: 513 cases who applied to the Emergency Service and Department of Thoracic Surgery between October 2013 and December 2014 due to blunt trauma and were diagnosed with rib fracture were retrospectively examined. The cases were evaluated in terms of etiological factors, thoracic, and other system injuries accompanying the rib fracture, prognosis, and the treatments applied. Results: Isolated rib fracture was present in 266 of the cases. Thoracic organ injuries such as pneumothorax, hemothorax, hemopneumothorax, lung contusion, or laceration and sternal fracture accompanying the rib fracture were present in 247 of the cases. While one or two rib fractures were detected in 298 cases, six or more rib fractures were present in 28 cases. 78.2% of hemothorax cases, 85.3% of pneumothorax cases, 95.4% of hemopneumothorax cases, 81.8% of bilateral pneumothorax cases, 26% of bilateral hemothorax cases, and 71.4% of bilateral hemopneumothorax cases were treated by applying tube thoracostomy. 129 cases diagnosed with thoracic organ injury in addition to rib fracture but not subjected to surgical intervention, and 266 cases diagnosed with isolated rib fracture were discharged with full recovery after appropriate medical treatment. Discussion: Most of the rib fractures occurring due to blunt trauma are treated successfully with medical treatments and conservative approaches and do not need advanced surgical treatments.

  7. Model based rib-cage unfolding for trauma CT

    Science.gov (United States)

    von Berg, Jens; Klinder, Tobias; Lorenz, Cristian

    2018-03-01

    A CT rib-cage unfolding method is proposed that does not require to determine rib centerlines but determines the visceral cavity surface by model base segmentation. Image intensities are sampled across this surface that is flattened using a model based 3D thin-plate-spline registration. An average rib centerline model projected onto this surface serves as a reference system for registration. The flattening registration is designed so that ribs similar to the centerline model are mapped onto parallel lines preserving their relative length. Ribs deviating from this model appear deviating from straight parallel ribs in the unfolded view, accordingly. As the mapping is continuous also the details in intercostal space and those adjacent to the ribs are rendered well. The most beneficial application area is Trauma CT where a fast detection of rib fractures is a crucial task. Specifically in trauma, automatic rib centerline detection may not be guaranteed due to fractures and dislocations. The application by visual assessment on the large public LIDC data base of lung CT proved general feasibility of this early work.

  8. Generalization of results on experimental study on resistance of ribbed tube bundles

    International Nuclear Information System (INIS)

    Lokshin, V.A.; Fomina, V.N.

    1978-01-01

    On a wide experimental basis a new technique of calculating aerodynamic resistance of chess and passage tube bundles is worked out using inner diameter of carrier tube and ribbing coefficient as geometric parameters in formulae. New calculated formulae are based on a wider experimental material. Their structure is more simple. They are in good agreement with formulae for smooth tube bundles in the chess arrangement

  9. Clinical Utility of Chest Computed Tomography in Patients with Rib Fractures CT Chest and Rib Fractures.

    Science.gov (United States)

    Chapman, Brandon C; Overbey, Douglas M; Tesfalidet, Feven; Schramm, Kristofer; Stovall, Robert T; French, Andrew; Johnson, Jeffrey L; Burlew, Clay C; Barnett, Carlton; Moore, Ernest E; Pieracci, Fredric M

    2016-12-01

    Chest CT is more sensitive than a chest X-ray (CXR) in diagnosing rib fractures; however, the clinical significance of these fractures remains unclear. The purpose of this study was to determine the added diagnostic use of chest CT performed after CXR in patients with either known or suspected rib fractures secondary to blunt trauma. Retrospective cohort study of blunt trauma patients with rib fractures at a level I trauma center that had both a CXR and a CT chest. The CT finding of ≥ 3 additional fractures in patients with ≤ 3 rib fractures on CXR was considered clinically meaningful. Student's t-test and chi-square analysis were used for comparison. We identified 499 patients with rib fractures: 93 (18.6%) had CXR only, 7 (1.4%) had chest CT only, and 399 (79.9%) had both CXR and chest CT. Among these 399 patients, a total of 1,969 rib fractures were identified: 1,467 (74.5%) were missed by CXR. The median number of additional fractures identified by CT was 3 (range, 4 - 15). Of 212 (53.1%) patients with a clinically meaningful increase in the number of fractures, 68 patients underwent one or more clinical interventions: 36 SICU admissions, 20 pain catheter placements, 23 epidural placements, and 3 SSRF. Additionally, 70 patients had a chest tube placed for retained hemothorax or occult pneumothorax. Overall, 138 patients (34.5%) had a change in clinical management based upon CT chest. The chest X-ray missed ~75% of rib fractures seen on chest CT. Although patients with a clinical meaningful increase in the number of rib fractures were more likely to be admitted to the intensive care unit, there was no associated improvement in pulmonary outcomes.

  10. Novel classification system of rib fractures observed in infants.

    Science.gov (United States)

    Love, Jennifer C; Derrick, Sharon M; Wiersema, Jason M; Pinto, Deborrah C; Greeley, Christopher; Donaruma-Kwoh, Marcella; Bista, Bibek

    2013-03-01

    Rib fractures are considered highly suspicious for nonaccidental injury in the pediatric clinical literature; however, a rib fracture classification system has not been developed. As an aid and impetus for rib fracture research, we developed a concise schema for classifying rib fracture types and fracture location that is applicable to infants. The system defined four fracture types (sternal end, buckle, transverse, and oblique) and four regions of the rib (posterior, posterolateral, anterolateral, and anterior). It was applied to all rib fractures observed during 85 consecutive infant autopsies. Rib fractures were found in 24 (28%) of the cases. A total of 158 rib fractures were identified. The proposed schema was adequate to classify 153 (97%) of the observed fractures. The results indicate that the classification system is sufficiently robust to classify rib fractures typically observed in infants and should be used by researchers investigating infant rib fractures. © 2013 American Academy of Forensic Sciences.

  11. Optimal hydraulic design of new-type shaft tubular pumping system

    International Nuclear Information System (INIS)

    Zhu, H G; Zhang, R T; Zhou, J R

    2012-01-01

    Based on the characteristics of large flow rate, low-head, short annual operation time and high reliability of city flood-control pumping stations, a new-type shaft tubular pumping system featuring shaft suction box, siphon-type discharge passage with vacuum breaker as cutoff device was put forward, which possesses such advantages as simpler structure, reliable cutoff and higher energy performance. According to the design parameters of a city flood control pumping station, a numerical computation model was set up including shaft-type suction box, siphon-type discharge passage, pump impeller and guide vanes. By using commercial CFD software Fluent, RNG κ-ε turbulence model was adopted to close the three-dimensional time-averaged incompressible N-S equations. After completing optimal hydraulic design of shaft-type suction box, and keeping the parameters of total length, maximum width and outlet section unchanged, siphon-type discharge passages of three hump locations and three hump heights were designed and numerical analysis on the 9 hydraulic design schemes of pumping system were proceeded. The computational results show that the changing of hump locations and hump heights directly affects the internal flow patterns of discharge passages and hydraulic performances of the system, and when hump is located 3.66D from the inlet section and hump height is about 0.65D (D is the diameter of pump impeller), the new-type shaft tubular pumping system achieves better energy performances. A pumping system model test of the optimal designed scheme was carried out. The result shows that the highest pumping system efficiency reaches 75.96%, and when at design head of 1.15m the flow rate and system efficiency were 0.304m 3 /s and 63.10%, respectively. Thus, the validity of optimal design method was verified by the model test, and a solid foundation was laid for the application and extension of the new-type shaft tubular pumping system.

  12. A 3' UTR-derived non-coding RNA RibS increases expression of cfa and promotes biofilm formation of Salmonella enterica serovar Typhi.

    Science.gov (United States)

    Zhao, Xin; Liu, Rui; Tang, Hao; Osei-Adjei, George; Xu, Shungao; Zhang, Ying; Huang, Xinxiang

    2018-05-08

    Bacterial non-coding RNAs (ncRNAs) are widely studied and found to play important roles in regulating various cellular processes. Recently, many ncRNAs have been discovered to be transcribed or processed from 3' untranslated regions (3' UTRs). Here we reported a novel 3' UTR-derived ncRNA, RibS, which could influence biofilm formation of Salmonella enterica serovar Typhi (S. Typhi). RibS was confirmed to be a ∼700 nt processed product produced by RNase III-catalyzed cleavage from the 3' UTR of riboflavin synthase subunit alpha mRNA, RibE. Overexpression of RibS increased the expression of the cyclopropane fatty acid synthase gene, cfa, which was located at the antisense strand. Biofilm formation of S. Typhi was enhanced by overexpressing RibS both in the wild type strain and cfa deletion mutant. Deletion of cfa attenuated biofilm formation of S. Typhi, while complementation of cfa partly restored the phenotype. Moreover, overexpressing cfa enhanced the biofilm formation of S. Typhi. In summary, RibS has been identified as a novel ncRNA derived from the 3' UTR of RibE that promotes biofilm formation of S. Typhi, and it appears to do so, at least in part, by increasing the expression of cfa. Copyright © 2018 Institut Pasteur. Published by Elsevier Masson SAS. All rights reserved.

  13. Non-censored rib fracture data during frontal PMHS sled tests.

    Science.gov (United States)

    Kemper, Andrew R; Beeman, Stephanie M; Porta, David J; Duma, Stefan M

    2016-09-01

    The purpose of this study was to obtain non-censored rib fracture data due to three-point belt loading during dynamic frontal post-mortem human surrogate (PMHS) sled tests. The PMHS responses were then compared to matched tests performed using the Hybrid-III 50(th) percentile male ATD. Matched dynamic frontal sled tests were performed on two male PMHSs, which were approximately 50(th) percentile height and weight, and the Hybrid-III 50(th) percentile male ATD. The sled pulse was designed to match the vehicle acceleration of a standard sedan during a FMVSS-208 40 kph test. Each subject was restrained with a 4 kN load limiting, driver-side, three-point seatbelt. A 59-channel chestband, aligned at the nipple line, was used to quantify the chest contour, anterior-posterior sternum deflection, and maximum anterior-posterior chest deflection for all test subjects. The internal sternum deflection of the ATD was quantified with the sternum potentiometer. For the PMHS tests, a total of 23 single-axis strain gages were attached to the bony structures of the thorax, including the ribs, sternum, and clavicle. In order to create a non-censored data set, the time history of each strain gage was analyzed to determine the timing of each rib fracture and corresponding timing of each AIS level (AIS = 1, 2, 3, etc.) with respect to chest deflection. Peak sternum deflection for PMHS 1 and PMHS 2 were 48.7 mm (19.0%) and 36.7 mm (12.2%), respectively. The peak sternum deflection for the ATD was 20.8 mm when measured by the chest potentiometer and 34.4 mm (12.0%) when measured by the chestband. Although the measured ATD sternum deflections were found to be well below the current thoracic injury criterion (63 mm) specified for the ATD in FMVSS-208, both PMHSs sustained AIS 3+ thoracic injuries. For all subjects, the maximum chest deflection measured by the chestband occurred to the right of the sternum and was found to be 83.0 mm (36.0%) for PMHS 1, 60.6 mm (23.9%) for PMHS 2

  14. Simulation and measurement of enhanced turbulent heat transfer in a channel with periodic ribs on one principal wall

    International Nuclear Information System (INIS)

    Tongmin Liou; Jennjiang Hwang; Shihhui Chen

    1993-01-01

    This paper performs a numerical and experimental analysis to investigate the heat transfer and fluid flow behaviour in a rectangular channel flow with streamwise-periodic ribs mounted on one of the principal walls. The k --A PDM turbulence model together with a smoothed hybrid central/skew upstream difference scheme (SCSUDS) and the PISO pressure-velocity coupling algorithm was applied to solving the accelerated, separated and recirculating flows. The real-time holographic interferometry technique was adopted to measure the time-dependent temperature field in the ribbed duct. The predicted fluid flow and temperature field were tested by previous laser-Doppler velocimetry measurements and present holographic interferometry data, and reasonable agreement was achieved. By the examination of the local wall temperature distribution for the uniform wall heat flux (UHF) boundary condition the regions susceptible to the hot spots are identified. Moreover, the study provided the numerical solution to investigate the effect of geometry and flow parameters on the local as well as average heat transfer coefficients. The compact correlation of the average heat transfer coefficient was further developed and accounted for the rib height, rib spacing, and Reynolds number. (Author)

  15. ACR Appropriateness Criteria® rib fractures.

    Science.gov (United States)

    Henry, Travis S; Kirsch, Jacobo; Kanne, Jeffrey P; Chung, Jonathan H; Donnelly, Edwin F; Ginsburg, Mark E; Heitkamp, Darel E; Kazerooni, Ella A; Ketai, Loren H; McComb, Barbara L; Parker, J Anthony; Ravenel, James G; Restrepo, Carlos Santiago; Saleh, Anthony G; Shah, Rakesh D; Steiner, Robert M; Suh, Robert D; Mohammed, Tan-Lucien H

    2014-11-01

    Rib fracture is the most common thoracic injury, present in 10% of all traumatic injuries and almost 40% of patients who sustain severe nonpenetrating trauma. Although rib fractures can produce significant morbidity, the diagnosis of associated complications (such as pneumothorax, hemothorax, pulmonary contusion, atelectasis, flail chest, cardiovascular injury, and injuries to solid and hollow abdominal organs) may have a more significant clinical impact. When isolated, rib fractures have a relatively low morbidity and mortality, and failure to detect isolated rib fractures does not necessarily alter patient management or outcome in uncomplicated cases. A standard posteroanterior chest radiograph should be the initial, and often the only, imaging test required in patients with suspected rib fracture after minor trauma. Detailed radiographs of the ribs rarely add additional information that would change treatment, and, although other imaging tests (eg, computed tomography, bone scan) have increased sensitivity for detection of rib fractures, there are little data to support their use. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed every 3 years by a multidisciplinary expert panel. The guideline development and review process include an extensive analysis of current medical literature from peer-reviewed journals and the application of a well-established consensus methodology (modified Delphi) to rate the appropriateness of imaging and treatment procedures by the panel. In those instances in which evidence is lacking or not definitive, expert opinion may be used to recommend imaging or treatment.

  16. Rib plating of acute and sub-acute non-union rib fractures in an adult with cystic fibrosis: a case report.

    Science.gov (United States)

    Dean, Nathan C; Van Boerum, Don H; Liou, Theodore G

    2014-10-01

    Rib fractures associated with osteoporosis have been reported to occur ten times more frequently in adults with cystic fibrosis. Fractures cause chest pain, and interfere with cough and sputum clearance leading to worsened lung function and acute exacerbations which are the two main contributors to early mortality in cystic fibrosis. Usual treatment involves analgesics and time for healing; however considerable pain and disability result due to constant re-injury from chronic repetitive cough. Recently, surgical plating of rib fractures has become commonplace in treating acute, traumatic chest injuries. We describe here successful surgical plating in a White cystic fibrosis patient with multiple, non-traumatic rib fractures. A-37-year old White male with cystic fibrosis was readmitted to Intermountain Medical Center for a pulmonary exacerbation. He had developed localized rib pain while coughing 2 months earlier, with worsening just prior to hospital admission in conjunction with a "pop" in the same location while bending over. A chest computerized tomography scan at admission demonstrated an acute 5th rib fracture and chronic non-united 6th and 7th right rib fractures. An epidural catheter was placed both for analgesia and to make secretion clearance possible in preparation for the surgery performed 2 days later. Under general anesthesia, he had open reduction and internal fixation of the right 5th, 6th and 7th rib fractures with a Synthes Matrix rib set. After several days of increased oxygen requirements, fever, fluid retention, and borderline vital signs, he stabilized. Numerical pain rating scores from his ribs were lower post-operatively and he was able to tolerate chest physical therapy and vigorous coughing. In our case report, rib plating with bone grafting improved rib pain and allowed healing of the fractures and recovery, although the immediate post-op period required close attention and care. We believe repair may be of benefit in selected cystic

  17. The relationship between tree height and leaf area: sapwood area ratio.

    Science.gov (United States)

    McDowell, N; Barnard, H; Bond, B; Hinckley, T; Hubbard, R; Ishii, H; Köstner, B; Magnani, F; Marshall, J; Meinzer, F; Phillips, N; Ryan, M; Whitehead, D

    2002-06-01

    The leaf area to sapwood area ratio (A l :A s ) of trees has been hypothesized to decrease as trees become older and taller. Theory suggests that A l :A s must decrease to maintain leaf-specific hydraulic sufficiency as path length, gravity, and tortuosity constrain whole-plant hydraulic conductance. We tested the hypothesis that A l :A s declines with tree height. Whole-tree A l :A s was measured on 15 individuals of Douglas-fir (Pseudotsuga menziesii var. menziesii) ranging in height from 13 to 62 m (aged 20-450 years). A l :A s declined substantially as height increased (P=0.02). Our test of the hypothesis that A l :A s declines with tree height was extended using a combination of original and published data on nine species across a range of maximum heights and climates. Meta-analysis of 13 whole-tree studies revealed a consistent and significant reduction in A l :A s with increasing height (P<0.05). However, two species (Picea abies and Abies balsamea) exhibited an increase in A l :A s with height, although the reason for this is not clear. The slope of the relationship between A l :A s and tree height (ΔA l :A s /Δh) was unrelated to mean annual precipitation. Maximum potential height was positively correlated with ΔA l :A s /Δh. The decrease in A l :A s with increasing tree size that we observed in the majority of species may be a homeostatic mechanism that partially compensates for decreased hydraulic conductance as trees grow in height.

  18. Close relationship between diameters at 30cm height and at breast height (DBH Relações entre diametros a 30 cm de altura e à altura do peito (DAP

    Directory of Open Access Journals (Sweden)

    Christoph Gehring

    2008-01-01

    Full Text Available This paper proposes the establishment of a second diameter measuring standard at 30cm shoot extension ('diam30' as input variable for allometric biomass estimation of small and mid-sized plant shoots. This diameter standard is better suited than the diameter at breast height (DBH, i.e. diameter at 1.30m shoot extension for adequate characterization of plant dimensions in low bushy vegetation or in primary forest undergrowth. The relationships between both diameter standards are established based on a dataset of 8645 tree, liana and palm shoots in secondary and primary forests of central Amazonia (ranging from 1-150mm dbh. Dbh can be predicted from the diam(30 with high precision, the error introduced by diameter transformation is only 2-3% for trees and palms, and 5% for lianas. This is well acceptable for most field study purposes. Relationships deviate slightly from linearity and differ between growth forms. Relationships were markedly similar for different vegetation types (low secondary regrowth vs. primary forests, soils, and selected genera or species. This points to a general validity and applicability of diameter transformations for other field studies. This study provides researchers with a tool for the allometric estimation of biomass in low or structurally heterogeneous vegetation. Rather than applying a uniform diameter standard, the measuring position which best represents the respective plant can be decided on shoot-by-shoot. Plant diameters measured at 30cm height can be transformed to dbh for subsequent allometric biomass estimation. We recommend the use of these diameter transformations only for plants extending well beyond the theoretical minimum shoot length (i.e., >2m height. This study also prepares the ground for the comparability and compatability of future allometric equations specifically developed for small- to mid-sized vegetation components (i.e., bushes, undergrowth which are based on the diam(30 measuring standard

  19. Posterior-only spinal fusion without rib head resection for treating type I neurofibromatosis with intra-canal rib head dislocation

    Directory of Open Access Journals (Sweden)

    Dong Sun

    2013-12-01

    Full Text Available OBJECTIVES: Patients with Type I neurofibromatosis scoliosis with intra-canal rib head protrusion are extremely rare. Current knowledge regarding the diagnosis and treatment for this situation are insufficient. The purpose of this study is to share our experience in the diagnosis and surgical treatments for such unique deformities. METHODS: Six patients with Type I neurofibromatosis scoliosis with rib head dislocation into the spinal canal were diagnosed at our institution. Posterior instrumentation and spinal fusion without intra-canal rib head resection via a posterior-only approach was performed for deformity correction and rib head extraction. The efficacy and outcomes of the surgery were evaluated by measurements before, immediately and 24 months after the surgery using the following parameters: coronal spinal Cobb angle, apex rotation and kyphosis of the spine and the intra-canal rib head position. Post-operative complications, surgery time and blood loss were also evaluated. RESULTS: Patients were followed up for at least 24 months post-operatively. The three dimensional spinal deformity was significantly improved and the intra-canal rib head was significantly extracted from the canal immediately after the surgery. At follow-up 24 months after surgery, solid fusions were achieved along the fusion segments, and the deformity corrections and rib head positions were well maintained. There were no surgery-related complications any time after the surgery. CONCLUSIONS: Systematic examinations are needed to identify patients with Type I neurofibromatosis scoliosis with rib head dislocation into the canal who can be treated by posterior-only spinal fusion without rib head resection.

  20. Ground level cosmic ray pulse height spectrum of a 7. 5 cm diameter spherical NaI(Tl) scintillation detector for energy region below 5 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, Toshi; Saito, Kimiaki; Moriuchi, Shigeru

    1988-09-01

    Ground level cosmic ray pulse height spectrum of a 7.5 cm diameter spherical NaI(Tl) scintillation detector was evaluated through stripping operation based on a pulse height spectrum measured on the sea and high precision response functions of the detector for U-series, Th-series and /sup 40/K. The exposure rate calculated from the determined cosmic ray pulse height spectrum was 0.21 R/h eq., which agreed well with that obtained from another method. The shape of the pulse height spectrum showed similarity to that measured at the altitude of 16,000 ft, especially in the energy region of 0 to 3 MeV. The principle of the adopted method is rather plain, however, the reliability of the spectrum is satisfactory. As the pulse height spectrum is a common information to any analytical method for environmental gamma ray using NaI(Tl) scintillation detector, it is expected to be used for simple and precise separation of cosmic ray component involved in the enviromental pulse height spectrum.

  1. Ground level cosmic ray pulse height spectrum of a 7.5 cm diameter spherical NaI(Tl) scintillation detector for energy region below 5 MeV

    International Nuclear Information System (INIS)

    Nagaoka, Toshi; Saito, Kimiaki; Moriuchi, Shigeru

    1988-01-01

    Ground level cosmic ray pulse height spectrum of a 7.5 cm diameter spherical NaI(Tl) scintillation detector was evaluated through stripping operation based on a pulse height spectrum measured on the sea and high precision response functions of the detector for U-series, Th-series and 40 K. The exposure rate calculated from the determined cosmic ray pulse height spectrum was 0.21 μR/h eq., which agreed well with that obtained from another method. The shape of the pulse height spectrum showed similarity to that measured at the altitude of 16,000 ft, especially in the energy region of 0 to 3 MeV. The principle of the adopted method is rather plain, however, the reliability of the spectrum is satisfactory. As the pulse height spectrum is a common information to any analytical method for environmental gamma ray using NaI(Tl) scintillation detector, it is expected to be used for simple and precise separation of cosmic ray component involved in the enviromental pulse height spectrum. (author)

  2. Evaluation of the Rib Lesions by Bone Scanning

    International Nuclear Information System (INIS)

    Park, Hyung Gun; Lee, Dong Soo; Lee, Myung Chul; Cho, Bo Youn; Koh, Chang Soon

    1983-01-01

    In order to establish criteria for distinguishing between occult fracture and metastases, we have reviewed 52 records of cancer patients and 24 of rib fracture patients referred for bone scanning. In 52 patients with biopsy-proven malignancy, multiple linear increased uptake of the ribs was found in 32 cases(61.5%), and was the most common finding. In 24 patients with rib fracture, all but 1 had fecal increased uptake of the ribs, and lesions almost always aligned in a row. By analyzing the appearance of rib lesions in total 76 patients, it was concluded that there is a high probability that rib lesions detected by bone scanning are bony metastases if 1) they are multiple linear as opposed to fecal, and 2) they are not aligned in the same location

  3. Comprehensive approach to the management of the patient with multiple rib fractures: a review and introduction of a bundled rib fracture management protocol.

    Science.gov (United States)

    Witt, Cordelie E; Bulger, Eileen M

    2017-01-01

    Rib fractures are common among patients sustaining blunt trauma, and are markers of severe bodily and solid organ injury. They are associated with high morbidity and mortality, including multiple pulmonary complications, and can lead to chronic pain and disability. Clinical and radiographic scoring systems have been developed at several institutions to predict risk of complications. Clinical strategies to reduce morbidity have been studied, including multimodal pain management, catheter-based analgesia, pulmonary hygiene, and operative stabilization. In this article, we review risk factors for morbidity and complications, intervention strategies, and discuss experience with bundled clinical pathways for rib fractures. In addition, we introduce the multidisciplinary rib fracture management protocol used at our level I trauma center.

  4. Rib necrosis after postoperative irradiation with 6MeV x-ray to breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Asakawa, H; Watarai, J; Otawa, H [Miyagi Prefectural Adult Disease Center, Natori (Japan)

    1975-04-01

    In order to examine quality of rays in radiation injury in the rib by high energy x-ray, radiation injury in the rib was roentgenologically followed up in the subjects that received postoperative irradiation only with 6 MeV x-ray to breast cancer. The subjects consisted of 79 patients with the age of 30 to 78 and were irradiated with 200 rads of 6 MeV x-ray 5 times a week delivered in 5 to 6 weeks postoperatively. Two fields were irradiated in a day and the total dose reached more than 5,000 rads. Roentgenologic follow up for more than 12 months revealed that rib necrosis occurred in 9 (11%) of 79 patients and that there was no relation to the age of patient. The necrosis was most likely to develop in the right second rib 10 to 23 months after the irradiation and the mean was 16 months. To the rib region where necrosis occurred, 1,880 to 2,230 ret were irradiated and the mean was 2,014 ret. There found no relation between the irradiation dose and occurrence of rib necrosis in the extent of 4,000 to 6,000 rads for tumor doses. Radiation injury in the lung was complicated in 8 (89%) of 9 patients with rib necrosis, indicating high incidence.

  5. A study of thermal-hydraulic requirements for increasing the power rates for natural-circulation boiling water reactors

    International Nuclear Information System (INIS)

    Yasuo, A.; Inada, F.; Hidaka, M.

    1992-01-01

    In this paper, the feasibility of higher power rates for natural-circulation boiling water reactors (BWRs) is studied with the objective of examining the flexibility of the plant power rate in constructing such plants to cope with the increasing demand for electricity. By applying existing one-dimensional design codes, the riser heights necessary to meet two major thermal-hydraulic requirements, i.e., critical power and core stability, are systematically calculated. Several restrictions on the maximum diameter and height of the pressure vessel are also considered because these restrictions could make construction impossible or drastically increase the construction costs. A very simple map of the dominant parameters for higher power rates is obtained. It is concluded that natural-circulation BWRs of >1000 MW (electric) will be feasible within the restrictions considered here

  6. Traumatic Rib Injury: Patterns, Imaging Pitfalls, Complications, and Treatment.

    Science.gov (United States)

    Talbot, Brett S; Gange, Christopher P; Chaturvedi, Apeksha; Klionsky, Nina; Hobbs, Susan K; Chaturvedi, Abhishek

    2017-01-01

    The ribs are frequently affected by blunt or penetrating injury to the thorax. In the emergency department setting, it is vital for the interpreting radiologist to not only identify the presence of rib injuries but also alert the clinician about organ-specific injury, specific traumatic patterns, and acute rib trauma complications that require emergent attention. Rib injuries can be separated into specific morphologic fracture patterns that include stress, buckle, nondisplaced, displaced, segmental, and pathologic fractures. Specific attention is also required for flail chest and for fractures due to pediatric nonaccidental trauma. Rib fractures are associated with significant morbidity and mortality, both of which increase as the number of fractured ribs increases. Key complications associated with rib fracture include pain, hemothorax, pneumothorax, extrapleural hematoma, pulmonary contusion, pulmonary laceration, acute vascular injury, and abdominal solid-organ injury. Congenital anomalies, including supernumerary or accessory ribs, vestigial anterior ribs, bifid ribs, and synostoses, are common and should not be confused with traumatic pathologic conditions. Nontraumatic mimics of traumatic rib injury, with or without fracture, include metastatic disease, primary osseous neoplasms (osteosarcoma, chondrosarcoma, Ewing sarcoma, Langerhans cell histiocytosis, and osteochondroma), fibrous dysplasia, and Paget disease. Principles of management include supportive and procedural methods of alleviating pain, treating complications, and stabilizing posttraumatic deformity. By recognizing and accurately reporting the imaging findings, the radiologist will add value to the care of patients with thoracic trauma. Online supplemental material is available for this article. © RSNA, 2017.

  7. Study of thermal and hydraulic efficiency of supersonic tube of temperature stratification

    Science.gov (United States)

    Tsynaeva, Anna A.; Nikitin, Maxim N.; Tsynaeva, Ekaterina A.

    2017-10-01

    Efficiency of supersonic pipe for temperature stratification with finned subsonic surface of heat transfer is the major of this paper. Thermal and hydraulic analyses of this pipe were conducted to asses effects from installation of longitudinal rectangular and parabolic fins as well as studs of cylindrical, rectangular and parabolic profiles. The analysis was performed based on refined empirical equations of similarity, dedicated to heat transfer of high-speed gas flow with plain wall, and Kármán equation with Nikuradze constants. Results revealed cylindrical studs (with height-to-diameter ratio of 5:1) to be 1.5 times more efficient than rectangular fins of the same height. At the same time rectangular fins (with height-to-thickness ratio of 5:1) were tend to enhance heat transfer rate up to 2.67 times compared to bare walls from subsonic side of the pipe. Longitudinal parabolic fins have minuscule effect on combined efficiency of considered pipe since extra head losses void any gain of heat transfer. Obtained results provide perspective of increasing efficiency of supersonic tube for temperature stratification. This significantly broadens device applicability in thermostatting systems for equipment, cooling systems for energy converting machinery, turbine blades and aerotechnics.

  8. Rib fractures in blunt chest trauma - associated thoracic injuries

    Directory of Open Access Journals (Sweden)

    Iv. Dimitrov

    2017-09-01

    Full Text Available PURPOSE. The aim of our retrospective study was to analyze the patterns of associated thoracic injuries in patients underwent blunt chest trauma and rib fractures. METHODS. The study included 212 patients with rib fractures due to blunt thoracic trauma. The mechanism of trauma, the type of rib fracture and the type of associated injuries were analyzed. RESULTS. The patients were divided in two groups according to the number of fractured ribs-group I included the patients with up to two fractured ribs (72 patients-33,9%, and group II – with ≥3 fractured ribs (140 patients-66,1%. Associated chest injuries were present in 36 of the patients from group I (50%, and in 133 patients from group II (95%. Pulmonary contusion was the most common intrathoracicinjurie-65,6% of the cases. The mean hospital stay was 8, 7 days. The lethality rate was 16,9% -all of them due to the associated chest injuries. CONCLUSIONS. The mortality related to rib fractures is affected by the associated thoracic injuries, the advanced age, and the number of fractured ribs.

  9. Evaluation of Rib Fractures on a Single-in-plane Image Reformation of the Rib Cage in CT Examinations.

    Science.gov (United States)

    Dankerl, Peter; Seuss, Hannes; Ellmann, Stephan; Cavallaro, Alexander; Uder, Michael; Hammon, Matthias

    2017-02-01

    This study aimed to evaluate the diagnostic performance of using a reformatted single-in-plane image reformation of the rib cage for the detection of rib fractures in computed tomography (CT) examinations, employing different levels of radiological experience. We retrospectively evaluated 10 consecutive patients with and 10 patients without rib fractures, whose CT scans were reformatted to a single-in-plane image reformation of the rib cage. Eight readers (two radiologists, two residents in radiology, and four interns) independently evaluated the images for the presence of rib fractures using a reformatted single-in-plane image and a multi-planar image reformation. The time limit was 30 seconds for each read. A consensus of two radiologist readings was considered as the reference standard. Diagnostic performance (sensitivity, specificity, positive predictive value [PPV], and negative predictive value [NPV]) was assessed and evaluated per rib and per location (anterior, lateral, posterior). To determine the time limit, we prospectively analyzed the average time it took radiologists to assess the rib cage, in a bone window setting, in 50 routine CT examinations. McNemar test was used to compare the diagnostic performances. Single image reformation was successful in all 20 patients. The sensitivity, specificity, PPV, and NPV for the detection of rib fractures using the conventional multi-planar read were 77.5%, 99.2%, 89.9%, and 98.0% for radiologists; 46.3%, 99.7%, 92.5%, and 95.3% for residents; and 29.4%, 99.4%, 82.5%, and 93.9% for interns, respectively. Sensitivity, PPV, and NPV increased across all three groups of experience, using the reformatted single-in-plane image of the rib cage (radiologists: 85.0%, 98.6%, and 98.7%; residents: 80.0%, 92.8%, and 98.2%; interns: 66.9%, 89.9%, and 97.1%), whereas specificity did not change significantly (99.9%, 99.4%, and 99.3%). The diagnostic performance of the interns and residents was significantly better when

  10. What accounts for rib fractures in older adults?

    Science.gov (United States)

    Wuermser, Lisa-Ann; Achenbach, Sara J; Amin, Shreyasee; Khosla, Sundeep; Melton, L Joseph

    2011-01-01

    To address the epidemiology of rib fractures, an age- and sex-stratified random sample of 699 Rochester, Minnesota, adults age 21-93 years was followed in a long-term prospective study. Bone mineral density (BMD) was assessed at baseline, and fractures were ascertained by periodic interview and medical record review. During 8560 person-years of followup (median, 13.9 years), 56 subjects experienced 67 rib fracture episodes. Risk factors for falling predicted rib fractures as well as BMD, but both were strongly age-related. After age-adjustment, BMD was associated with rib fractures in women but not men. Importantly, rib fractures attributed to severe trauma were associated with BMD in older individuals of both sexes. Self-reported heavy alcohol use doubled fracture risk but did not achieve significance due to limited statistical power. Bone density, along with heavy alcohol use and other risk factors for falling, contributes to the risk of rib fractures, but no one factor predominates. Older women with rib fractures, regardless of cause, should be considered for an osteoporosis evaluation, and strategies to prevent falling should be considered in both sexes.

  11. What Accounts for Rib Fractures in Older Adults?

    Directory of Open Access Journals (Sweden)

    Lisa-Ann Wuermser

    2011-01-01

    Full Text Available To address the epidemiology of rib fractures, an age- and sex-stratified random sample of 699 Rochester, Minnesota, adults age 21–93 years was followed in a long-term prospective study. Bone mineral density (BMD was assessed at baseline, and fractures were ascertained by periodic interview and medical record review. During 8560 person-years of followup (median, 13.9 years, 56 subjects experienced 67 rib fracture episodes. Risk factors for falling predicted rib fractures as well as BMD, but both were strongly age-related. After age-adjustment, BMD was associated with rib fractures in women but not men. Importantly, rib fractures attributed to severe trauma were associated with BMD in older individuals of both sexes. Self-reported heavy alcohol use doubled fracture risk but did not achieve significance due to limited statistical power. Bone density, along with heavy alcohol use and other risk factors for falling, contributes to the risk of rib fractures, but no one factor predominates. Older women with rib fractures, regardless of cause, should be considered for an osteoporosis evaluation, and strategies to prevent falling should be considered in both sexes.

  12. What Accounts for Rib Fractures in Older Adults?

    Science.gov (United States)

    Wuermser, Lisa-Ann; Achenbach, Sara J.; Amin, Shreyasee; Khosla, Sundeep; Melton, L. Joseph

    2011-01-01

    To address the epidemiology of rib fractures, an age- and sex-stratified random sample of 699 Rochester, Minnesota, adults age 21–93 years was followed in a long-term prospective study. Bone mineral density (BMD) was assessed at baseline, and fractures were ascertained by periodic interview and medical record review. During 8560 person-years of followup (median, 13.9 years), 56 subjects experienced 67 rib fracture episodes. Risk factors for falling predicted rib fractures as well as BMD, but both were strongly age-related. After age-adjustment, BMD was associated with rib fractures in women but not men. Importantly, rib fractures attributed to severe trauma were associated with BMD in older individuals of both sexes. Self-reported heavy alcohol use doubled fracture risk but did not achieve significance due to limited statistical power. Bone density, along with heavy alcohol use and other risk factors for falling, contributes to the risk of rib fractures, but no one factor predominates. Older women with rib fractures, regardless of cause, should be considered for an osteoporosis evaluation, and strategies to prevent falling should be considered in both sexes. PMID:22028986

  13. Chondroblastoma of rib : case report

    International Nuclear Information System (INIS)

    Kim, Dong Hun; Kim, Kyung Rae; Ryu, Sang Wan

    2004-01-01

    Chondroblastoma is an uncommon, benign, cartilaginous neoplasm originating in an epiphysis or apophysis of a long tubular bone. The rib is an unusual site for chondroblastoma. The authors describe a case of chondroblastoma of the rib and present a brief review of the literature

  14. Chondroblastoma of rib : case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hun; Kim, Kyung Rae; Ryu, Sang Wan [Kwangju Hospital, Kwangju (Korea, Republic of)

    2004-07-01

    Chondroblastoma is an uncommon, benign, cartilaginous neoplasm originating in an epiphysis or apophysis of a long tubular bone. The rib is an unusual site for chondroblastoma. The authors describe a case of chondroblastoma of the rib and present a brief review of the literature.

  15. Study of the equivalent diameter concept for heat transfer by forced convection in annular channels

    International Nuclear Information System (INIS)

    Mendez T, D.

    1994-01-01

    This work describes a comparative analysis between experimental values of heat transfer coefficients in fully developed turbulent flow for a concentric annular channel, and those calculated with the empirical correlations obtained for tubes by Dittus-Boelter, Sieder and Tate, a modified Colburn equation, and that proposed by Gnielinski which applies the analogy between friction and heat transfer. The coefficients were calculated by means of two different equivalent diameters: 1) The hydraulic equivalent diameter; and 2) The heated equivalent diameter. It was concluded that the hydraulic equivalent diameter gives much better results than the heated equivalent diameter. (Author)

  16. Potential Benefits of Rib Fracture Fixation in Patients with Flail Chest and Multiple Non-flail Rib Fractures.

    Science.gov (United States)

    Qiu, Meiguang; Shi, Zhanjun; Xiao, Jun; Zhang, Xuming; Ling, Shishui; Ling, Hao

    2016-12-01

    The purpose of this study is to evaluate the potential benefits of rib fracture fixation in patients with flail chest and multiple non-flail rib fractures versus conventional treatment modalities. A retrospective reviewed study compared 86 cases which received surgical treatment between June 2009 and May 2013 to 76 cases which received conservative treatment between January 2006 and May 2009. The patients were divided into the flail chest ( n  = 38) and multiple non-flail rib fracture groups ( n  = 124). In the flail chest group, the mechanical ventilation time, ICU monitoring time, tracheostomies, thoracic deformity, and impaired pulmonary function and return to full-time employment were compared. In the multiple non-flail rib fracture group, fracture healing, visual analog scale (VAS) pain score, inpatient length of stay, atelectatic, pulmonary complications, and normal activity-returning time were compared. Patients in the flail chest operative fixation group had significantly shorter ICU stay, decreased ventilator requirements, fewer tracheostomies, less thoracic deformity and impaired pulmonary function, and more returned to full-time employment. Patients in the multiple non-flail rib fracture operative fixation had shorter hospital stay, less pain, earlier return to normal activity, more fracture healing, less atelectasis, and fewer pulmonary infections. This study demonstrates the potential benefits of surgical stabilization of flail chest and multiple non-flail rib fractures with plate fixation. When compared with conventional conservative management, operatively managed patients demonstrated improved clinical outcomes.

  17. Radiation-Induced Rib Fractures After Hypofractionated Stereotactic Body Radiation Therapy: Risk Factors and Dose-Volume Relationship

    Energy Technology Data Exchange (ETDEWEB)

    Asai, Kaori [Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan); Shioyama, Yoshiyuki, E-mail: shioyama@radiol.med.kyushu-u.ac.jp [Department of Heavy Particle Therapy and Radiation Oncology, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan); Nakamura, Katsumasa; Sasaki, Tomonari; Ohga, Saiji; Nonoshita, Takeshi [Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan); Yoshitake, Tadamasa [Department of Heavy Particle Therapy and Radiation Oncology, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan); Ohnishi, Kayoko [Department of Radiology, National Center for Global Health and Medicine, Tokyo (Japan); Terashima, Kotaro; Matsumoto, Keiji [Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan); Hirata, Hideki [Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan); Honda, Hiroshi [Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan)

    2012-11-01

    Purpose: The purpose of this study was to clarify the incidence, the clinical risk factors, and the dose-volume relationship of radiation-induced rib fracture (RIRF) after hypofractionated stereotactic body radiation therapy (SBRT). Methods and Materials: One hundred sixteen patients treated with SBRT for primary or metastatic lung cancer at our institution, with at least 6 months of follow-up and no previous overlapping radiation exposure, were included in this study. To determine the clinical risk factors associated with RIRF, correlations between the incidence of RIRF and the variables, including age, sex, diagnosis, gross tumor volume diameter, rib-tumor distance, and use of steroid administration, were analyzed. Dose-volume histogram analysis was also conducted. Regarding the maximum dose, V10, V20, V30, and V40 of the rib, and the incidences of RIRF were compared between the two groups divided by the cutoff value determined by the receiver operating characteristic curves. Results: One hundred sixteen patients and 374 ribs met the inclusion criteria. Among the 116 patients, 28 patients (46 ribs) experienced RIRF. The estimated incidence of rib fracture was 37.7% at 3 years. Limited distance from the rib to the tumor (<2.0 cm) was the only significant risk factor for RIRF (p = 0.0001). Among the dosimetric parameters used for receiver operating characteristic analysis, the maximum dose showed the highest area under the curve. The 3-year estimated risk of RIRF and the determined cutoff value were 45.8% vs. 1.4% (maximum dose, {>=}42.4 Gy or less), 51.6% vs. 2.0% (V40, {>=}0.29 cm{sup 3} or less), 45.8% vs. 2.2% (V30, {>=}1.35 cm{sup 3} or less), 42.0% vs. 8.5% (V20, {>=}3.62 cm{sup 3} or less), or 25.9% vs. 10.5% (V10, {>=}5.03 cm{sup 3} or less). Conclusions: The incidence of RIRF after hypofractionated SBRT is relatively high. The maximum dose and high-dose volume are strongly correlated with RIRF.

  18. Rib fracture repair: indications, technical issues, and future directions.

    Science.gov (United States)

    Nirula, Raminder; Diaz, Jose J; Trunkey, Donald D; Mayberry, John C

    2009-01-01

    Rib fracture repair has been performed at selected centers around the world for more than 50 years; however, the operative indications have not been established and are considered controversial. The outcome of a strictly nonoperative approach may not be optimal. Potential indications for rib fracture repair include flail chest, painful, movable rib fractures refractory to conventional pain management, chest wall deformity/defect, rib fracture nonunion, and during thoracotomy for other traumatic indication. Rib fracture repair is technically challenging secondary to the human rib's relatively thin cortex and its tendency to fracture obliquely. Nonetheless, several effective repair systems have been developed. Future directions for progress on this important surgical problem include the development of minimally invasive techniques and the conduct of multicenter, randomized trials.

  19. Rib Bone Graft Adjusted to Fit the Facial Asymmetry: A Frame Structure Graft.

    Science.gov (United States)

    Lee, Yoon Ho; Choi, Jong Hwan; Hwang, Kun; Choi, Jun Ho

    2015-10-01

    The authors introduce the concept of a "frame structure graft" in which a harvested rib bone was adjusted to fit facial asymmetry. On the costochondral junction of the sixth or seventh rib, a 5 cm incision was made. Through a subperiosteal dissection, the rib bone was harvested. Using a reciprocating saw, the harvested rib was scored on its anterior surface as well as its posterior surface with a partial depth at different intervals. The harvested rib bone was placed on the skin surface of the unaffected side of the face and a curvature was created exactly matching that of the unaffected side by bending the bone using a greenstick fracture. Thereafter, the graft was adjusted to conceal the asymmetry of the deficient side. The adjusted "frame structure" was transferred to the defect through the incisions on the affected side, and the "frame structure" graft was placed on the mandible or zygoma. The graft fixation was done externally with at least 2 Kirschner wires (K-wires). From January 2005 to August 2013, a total of 30 patients (13 men, 17 women, mean age 25.6 years) received a frame structure graft. All 30 patients achieved good healing at the operation site without complications. Donor-site morbidity as pneumothorax from the rib bone harvest was not found. Merits of this frame structure graft, the authors think, are that this method could allow a similar curvature to the normal side. In addition, the procedure itself is easy.

  20. Rib enlargement in premature infants with bronchopulmonary dysplasia

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hye Kyung; Han, Kim Bokyung; Chang, Yun Sil; Choo, In Wook [Samsung Medical Center, School of Medicine, Sungkyunkwan University, Seoul (Korea, Republic of); Kim, Kyeong Ah [Anyang General Hospital, Anyang (Korea, Republic of)

    2000-04-01

    The purpose of this study is to describe the rib changes seen in patients with brochopulmonary dysplasia (BPD). Serial chest radiographs of nine premature infants with BPD who showed diffuse rib enlargement were reviewed for hyperinflation, which was compared with the observed degree of rib enlargement. Vibrator chest physiotherapy was performed in all cases, and five infants underwent conventional ventilation plus high frequency oscillatory ventilation therapy. Their calcium level was normal whereas alkaline phosphatase and phosphate levels were high. In all infants except one, liver enzyme levels were normal. For the treatment of patent ductus arteriosus, infection, and BPD, medications including indomethacin, antibiotics, and dexamethasone were administered. Vitamin D was given to all patients with total parenteral nutrition. Rib enlargement was found to be severe (n=3D4), moderate (n=3D3), or mild (n=3D2) with undulating margins or posterior tapering (n=3D2). Hyperinflation was noted in eight patients, in seven of whom it was moderate to severe. Among these seven, rib enlargement was severe (n=3D2), moderate (n=3D3), or mild (n=3D2). In one infant with mild hyperinflation, rib enlargement was severe. Bilateral irregular infiltrates and atelectases were noted in all patients. In BPD patients, rib enlargement may be seen. In order to differentiate this process from systemic bone disease or bony dysplasia, an awareness of the rib changes occurring in patients with BPD may be important. (author)

  1. Rib enlargement in premature infants with bronchopulmonary dysplasia

    International Nuclear Information System (INIS)

    Yoon, Hye Kyung; Han, Kim Bokyung; Chang, Yun Sil; Choo, In Wook; Kim, Kyeong Ah

    2000-01-01

    The purpose of this study is to describe the rib changes seen in patients with brochopulmonary dysplasia (BPD). Serial chest radiographs of nine premature infants with BPD who showed diffuse rib enlargement were reviewed for hyperinflation, which was compared with the observed degree of rib enlargement. Vibrator chest physiotherapy was performed in all cases, and five infants underwent conventional ventilation plus high frequency oscillatory ventilation therapy. Their calcium level was normal whereas alkaline phosphatase and phosphate levels were high. In all infants except one, liver enzyme levels were normal. For the treatment of patent ductus arteriosus, infection, and BPD, medications including indomethacin, antibiotics, and dexamethasone were administered. Vitamin D was given to all patients with total parenteral nutrition. Rib enlargement was found to be severe (n=3D4), moderate (n=3D3), or mild (n=3D2) with undulating margins or posterior tapering (n=3D2). Hyperinflation was noted in eight patients, in seven of whom it was moderate to severe. Among these seven, rib enlargement was severe (n=3D2), moderate (n=3D3), or mild (n=3D2). In one infant with mild hyperinflation, rib enlargement was severe. Bilateral irregular infiltrates and atelectases were noted in all patients. In BPD patients, rib enlargement may be seen. In order to differentiate this process from systemic bone disease or bony dysplasia, an awareness of the rib changes occurring in patients with BPD may be important. (author)

  2. Bilateral first rib fractures: A case report

    Directory of Open Access Journals (Sweden)

    Dilip Amonkar

    2014-01-01

    Full Text Available From the time first rib fractures were first described in 1869, they have been a source of anxiety to attendant trauma surgeons working in the accident and emergency department of major hospitals. First rib fractures are associated with major thoracic trauma and may involve injury to subclavian vessels, brachial plexus, and mediastinal structures. But these complications are more often seen following unilateral first rib fractures. In contrast, bilateral first rib fractures may follow insignificant trauma, suggesting a different mechanism involved. Serious vascular injuries and brachial plexus injuries are rare and angiograms for evaluation of these patients aren′t routinely warranted. The case that we report illustrates this very point.

  3. Surgical Management of Rib Fractures: Strategies and Literature Review.

    Science.gov (United States)

    de Jong, M B; Kokke, M C; Hietbrink, F; Leenen, L P H

    2014-06-01

    Rib fractures can cause significant problems in trauma patients, often resulting in pain and difficulty with respiration. To prevent pulmonary complications and decrease the morbidity and mortality rates of patients with rib fractures, currently there is a trend to provide surgical management of patients with flail chest. However, the indications for rib fracture fixation require further specification. Past and current strategies are described according to a review of the medical literature. A systematic review was performed including current indications for rib fracture fixation. MEDLINE (2000-2013) was searched, as well as Embase (2000-2013) and Cochrane Databases, using the keywords rib, fracture, fixation, plate, repair, and surgery. Three retrospective studies were found that described different techniques for rib fracture fixation. The results demonstrated a reduced number of ventilation days, decreased long-term morbidity and pain, and satisfactory rehabilitation after surgical treatment. In addition to flail chest, age, Injury Severity Score, and the number of rib fractures were important predictive factors for morbidity and mortality. Surgical rib fracture fixation might be indicated in a broader range of cases than is currently performed. Prospective randomized trials are needed for further confirmation. © The Finnish Surgical Society 2014.

  4. Clinical prognostic factors and grading system for rib fracture following stereotactic body radiation therapy (SBRT) in patients with peripheral lung tumors.

    Science.gov (United States)

    Kim, Su Ssan; Song, Si Yeol; Kwak, Jungwon; Ahn, Seung Do; Kim, Jong Hoon; Lee, Jung Shin; Kim, Woo Sung; Kim, Sang-We; Choi, Eun Kyung

    2013-02-01

    Several studies reported rib fractures following stereotactic body radiation therapy (SBRT) for peripheral lung tumors. We tried to investigate risk factors and grading system for rib fractures after SBRT. Of 375 primary or metastatic lung tumors (296 patients) which were treated with SBRT at the Asan Medical Center (2006-2009), 126 lesions (118 patients) were adjacent to the chest-wall (6 months; these were investigated in the present retrospective study. Three to four fractional doses of 10-20 Gy were delivered to 85-90% iso-dose volume of the isocenter dose. Rib fracture grade was defined from follow-up CT scans as the appearance of a fracture line (Gr1), dislocation of the fractured rib by more than half the rib diameter (Gr2), or the appearance of adjacent soft tissue edema (Gr3). Chest wall pain was assessed according to the Common Terminology Criteria for Adverse Events (CTCAE) v3.0. Correlations between dose-volume data and the development of rib fracture were then analyzed. The Kaplan-Meier method, log-rank tests, and chi-square tests were used for statistical analysis. The median age of the patients was 69 years (range: 19-90). Over a median follow-up period of 22 months (range: 7-62), 48 cases of rib fracture were confirmed. Median time to rib fracture was 17 months (range: 4-52). The 2-year actuarial risk of rib fracture was 42.4%. Maximal grade was Gr1 (n=28), Gr2 (n=8), or Gr3 (n=15). The incidence of moderate to severe chest wall pain (CTCAE Gr ≥ 2) increased with maximal fracture grade (17.5% for Gr0-1 and 60.9% for Gr2-3; prib fracture in the present study. Efforts to decrease chest wall dose should be made to reduce the risk of the rib fracture, particularly in high-risk patients. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  5. Scaling of Haversian canal surface area to secondary osteon bone volume in ribs and limb bones.

    Science.gov (United States)

    Skedros, John G; Knight, Alex N; Clark, Gunnar C; Crowder, Christian M; Dominguez, Victoria M; Qiu, Shijing; Mulhern, Dawn M; Donahue, Seth W; Busse, Björn; Hulsey, Brannon I; Zedda, Marco; Sorenson, Scott M

    2013-06-01

    Studies of secondary osteons in ribs have provided a great deal of what is known about remodeling dynamics. Compared with limb bones, ribs are metabolically more active and sensitive to hormonal changes, and receive frequent low-strain loading. Optimization for calcium exchange in rib osteons might be achieved without incurring a significant reduction in safety factor by disproportionally increasing central canal size with increased osteon size (positive allometry). By contrast, greater mechanical loads on limb bones might favor reducing deleterious consequences of intracortical porosity by decreasing osteon canal size with increased osteon size (negative allometry). Evidence of this metabolic/mechanical dichotomy between ribs and limb bones was sought by examining relationships between Haversian canal surface area (BS, osteon Haversian canal perimeter, HC.Pm) and bone volume (BV, osteonal wall area, B.Ar) in a broad size range of mature (quiescent) osteons from adult human limb bones and ribs (modern and medieval) and various adult and subadult non-human limb bones and ribs. Reduced major axis (RMA) and least-squares (LS) regressions of HC.Pm/B.Ar data show that rib and limb osteons cannot be distinguished by dimensional allometry of these parameters. Although four of the five rib groups showed positive allometry in terms of the RMA slopes, nearly 50% of the adult limb bone groups also showed positive allometry when negative allometry was expected. Consequently, our results fail to provide clear evidence that BS/BV scaling reflects a rib versus limb bone dichotomy whereby calcium exchange might be preferentially enhanced in rib osteons. Copyright © 2013 Wiley Periodicals, Inc.

  6. [Analysis of 163 rib fractures by imaging examination].

    Science.gov (United States)

    Song, Tian-fu; Wang, Chao-chao

    2014-12-01

    To explore the applications of imaging examination on rib fracture sites in forensic identification. Features including the sites, numbers of the processed imaging examination and the first radiological technology at diagnosis in 56 cases of rib fractures from 163 injuries were retrospectively analyzed. The detection rate of the rib fractures within 14 days was 65.6%. The initial detection rate of anterior rib fracture proceeded by X-ray was 76.2%, then 90.5% detected at a second time X-ray, while the detection rate of CT was 66.7% and 80.0%, respectively. The initial detec- tion rate of rib fracture in axillary section proceeded by X-ray was 27.6%, then 58.6% detected at a second time X-ray, while the detection rate of CT was 54.3% and 80.4%, respectively. The initial detection rate of posterior rib fracture proceeded by X-ray was 63.6%, then 81.8% detected at a second time X-ray, while the detection rate of CT was 50.0% and 70.0%, respectively. It is important to pay attention to the use of combined imaging examinations and the follow-up results. In the cases of suspicious for rib fracture in axillary section, CT examination is suggested in such false X-ray negative cases.

  7. Modified rib pivot lateral thoracotomy: a case series.

    Science.gov (United States)

    Appelgrein, C; Hosgood, G

    2018-01-01

    To describe a modified rib pivot thoracotomy and its clinical application in client-owned dogs and cats. Case series of 24 dogs and 1 cat requiring a thoracotomy. A lateral thoracic incision over the required thoracic segment was made. The latissimus dorsi muscle was reflected dorsally. The predetermined rib was identified and the periosteum overlying the rib was elevated circumferentially, avoiding the intercostal neurovascular structures. Holes were pre-placed above and below the proposed osteotomy site. The rib was osteotomised and pivoted cranially. The pleura was incised and the required intrathoracic procedure was then performed. The thoracic cavity was closed by pre-placement of a suture through the pre-placed holes within the osteotomised rib. The pleura and intercostal musculature were closed, avoiding the intercostal neurovascular structures. The rib was re-apposed and the lateral approach was closed. The cases included were reviewed for both the rib pivoted as per the procedure required and postoperative complications. The study group comprised 8 Staffordshire Bull Terriers, 2 Poodles, 2 German Shepherd Dogs, 1 each of Basset Hound, Rhodesian Ridgeback, Golden Retriever, Australian Shepherd, Vizsla, Bull Mastiff, Schnauzer, Jack Russell Terrier, Bulldog, Deerhound, Labrador Retriever and Australian Terrier, and 1 cat. A modified rib pivot thoracotomy was performed for lung lobectomy (n = 11), oesophagectomy (7), subtotal pericardectomy (5), patent ductus arteriosus ligation (1) and thoracic duct ligation (1). Follow-up ranged from 2 to 40 weeks postoperatively. Postoperative complications included seroma formation in two dogs. A modified rib pivot thoracotomy should be considered as an alternative lateral thoracic approach with good exposure, minimal complications and low morbidity. © 2018 Australian Veterinary Association.

  8. [Seasonal differences in the leaf hydraulic conductance of mature Acacia mangium in response to its leaf water use and photosynthesis].

    Science.gov (United States)

    Zhao, Ping; Sun, Gu-Chou; Ni, Guang-Yan; Zeng, Xiao-Ping

    2013-01-01

    In this study, measurements were made on the leaf water potential (psi1), stomatal conductance (g(s)), transpiration rate, leaf area index, and sapwood area of mature Acacia mangium, aimed to understand the relationships of the leaf hydraulic conductance (K1) with the leaf water use and photosynthetic characteristics of the A. mangium in wet season (May) and dry season (November). The ratio of sapwood area to leaf area (A(sp)/A(cl)) of the larger trees with an average height of 20 m and a diameter at breast height (DBH) of 0.26 m was 8.5% higher than that of the smaller trees with an average height of 14.5 m and a DBH of 0.19 m, suggesting that the larger trees had a higher water flux in their leaf xylem, which facilitated the water use of canopy leaf. The analysis on the vulnerability curve of the xylem showed that when the K1 decreased by 50%, the psi1 in wet season and dry season was -1.41 and -1.55 MPa, respectively, and the vulnerability of the xylem cavitation was higher in dry season than in wet season. The K1 peak value in wet season and dry season was 5.5 and 4.5 mmol x m(-2) x s(-1) x MPa(-1), and the maximum transpiration rate (T(r max)) was 3.6 and 1.8 mmol x m(-2) x s(-1), respectively. Both the K1 and T(r max), were obviously higher in wet season than in dry season. Within a day, the K1 and T(r), fluctuated many times, reflecting the reciprocated cycle of the xylem cavitation and refilling. The leaf stomatal closure occurred when the K1 declined over 50% or the psi1 reached -1.6 MPa. The g(s) would be maintained at a high level till the K1 declined over 50%. The correlation between the hydraulic conductance and photosynthetic rate was more significant in dry season than in wet season. The loss of leaf hydraulic conductance induced by seasonal change could be the causes of the decrease of T(r) and CO2 gas exchange.

  9. Outcomes after operative management of symptomatic rib nonunion.

    Science.gov (United States)

    Gauger, Erich M; Hill, Brian W; Lafferty, Paul M; Cole, Peter A

    2015-06-01

    To report the outcomes of rib reconstruction after painful nonunion. Retrospective case series. Level I trauma center. Between November 2007 and May 2013, 10 patients who presented with 16 rib nonunions and disabling pain were treated with reconstruction of their nonunited rib fractures. Rib nonunion reconstruction predominately with iliac crest bone graft and a tension band plate with a locked precontoured plating system for ribs. Demographic data, mechanism of injury, and number of rib nonunions were recorded. Operative procedure, length of follow-up, complications, Short Form Survey 36, and a patient questionnaire were also captured and documented. Eight of the 10 patients sustained their original fractures from a fall. Outcomes were available for the 10 patients at a mean follow-up of up of 18.6 months (range, 3-46 months). All 16 ribs went on to union with a mean time from reconstruction to union of 14.7 weeks (range, 12-24 weeks). At final follow-up, the mean mental and physical component Short Form Survey 36 scores were 54.4 and 43.5, respectively. Eight of the 10 patients were able to return to work and/or previous activities without limitations. Complications included 1 wound infection that resolved after irrigation and debridement with adjunctive antibiotics. One symptomatic implant was removed. Ten patients with 16 symptomatic rib nonunions were reconstructed using autologous bone graft and implant/mesh fixation manifesting in successful union with improved patient function and a low rate of complications. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  10. The clinical implications of severe low rib fracture in the management of diaphragm injury: A Case Control Study.

    Science.gov (United States)

    Kim, Seongyup; Choi, Woo Jin; Lee, Kawng Ho; Byun, Chun Sung; Bae, Keum Seok; Park, Il Hwan

    2017-06-01

    The objective of this study was to analyze the differences in clinical presentation and characteristics with regard to diaphragmatic injury between blunt trauma patients with severe low rib fractures and those without severe low rib fractures. The medical records of all patients with diaphragmatic injuries who were surgically treated at this level I trauma center, between January 2004 and December 2016 were reviewed. Patient notes, radiologic findings, and operative reports were evaluated. All of the diaphragmatic injuries were confirmed based on the operative findings. Rib fracture with displacement between the ends of the fracture of more than half the width of the fractured rib on computed tomography was classified as 'severe rib fracture'. Patients were categorized into 2 groups and analyzed: those who had more than one severe rib fracture in low ribs on the ipsilateral side of the diaphragm injury (Severe group), and those with no severe rib fracture (Non-severe group). Delayed diagnosis of diaphragmatic injury was more frequent in the Severe group than in the Non-severe group (81.8% vs 36.8%, p-value = 0.026). With regard to initial indications for operation, intrathoracic visceral herniation was more frequent in the Non-severe group (78.9% vs 18.2%, p-value = 0.002), while hemothorax was more frequent in the Severe group (63.6% vs 5.3%, p-value = 0.001). Central type diaphragmatic laceration was more frequent in the Non-severe group than in the Severe group (78.9% vs 18.2%, p-value = 0.002). The diameter of diaphragmatic injury was larger in the Non-severe group than in the Severe group (9.70 ± 4.10 cm vs 4.80 ± 3.60 cm, p-value = 0.004). The results of this study imply that a low threshold for thoracotomy or laparotomy should be considered in blunt trauma patients with severe low rib fractures for the purpose of hidden diaphragmatic injury detection and management. Copyright © 2017. Published by Elsevier Ltd.

  11. the Modeling of Hydraulic Jump Generated Partially on Sloping Apron

    Directory of Open Access Journals (Sweden)

    Shaker Abdulatif Jalil

    2017-12-01

    Full Text Available Modeling aims to characterize system behavior and achieve simulation close as possible of the reality. The rapid energy exchange in supercritical flow to generate quiet or subcritical flow in hydraulic jump phenomenon is important in design of hydraulic structures. Experimental and numerical modeling is done on type B hydraulic jump which starts first on sloping bed and its end on horizontal bed.  Four different apron slopes are used, for each one of these slopes the jump is generated on different locations by controlling the tail water depth.  Modelling validation is based on 120 experimental runs which they show that there is reliability. The air volume fraction which creates in through hydraulic jump varied between 0.18 and 0.28. While the energy exchanges process take place within 6.6, 6.1, 5.8, 5.5 of the average relative jump height for apron slopes of 0.18, 0.14, 0.10, 0.07 respectively. Within the limitations of this study, mathematical prediction model for relative hydraulic jump height is suggested.The model having an acceptable coefficient of determination.

  12. Estimation of the fustal diameter on the central knotty cylinder in oak basal logs, Chile

    Directory of Open Access Journals (Sweden)

    Patricio Corvalán Vera

    2018-01-01

    Full Text Available In order to determine the diameter of the central knotted cylinder both alive and dead, a total of 60 trees belonging to the upper quartile of diametric classes in unmanaged renewal of N. obliqua from the Maule foothills were sampled. It is assumed that these are determined by the lowest living and dead branch present in tree height, respectively. We analyzed the relationships between the diameter of the central knotty cylinder, and the diameters at the lower end of logs 1.2, 2.4 and 3.6 m above the stump, the normal diameter and the insertion height of the first branch. From the analysis it is deduced that: i the diameter of the live and dead central knotted cylinder increases linearly with the normal diameter of the tree, ii that the diameter at the smaller end of the logs increases as it does and decreases as increases in height above the ground and iii that the fustal diameter on the dead central knotty cylinder increases linearly with the normal diameter and the insertion height of the lowest dead branch of the tree, allowing to determine the zone of occlusion of the knots of the tree.

  13. Rib Fracture Fixation: Indications and Outcomes.

    Science.gov (United States)

    Senekjian, Lara; Nirula, Raminder

    2017-01-01

    Rib fractures are a frequently identified injury in the trauma population. Not only are multiple rib fractures painful, but they are associated with an increased risk of adverse outcomes. Pneumonia in particular can be devastating, especially to an elderly patient, but other complications such as prolonged ventilation and increased intensive care and hospital durations of stay have a negative impact on the patient. Computed tomography scan is the best modality to diagnosis rib fractures but the treatment of fractures is still evolving. Currently patient care involves a multidisciplinary approach that includes pain control, aggressive pulmonary therapy, and possibly surgical fixation. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Hydraulic correction method (HCM) to enhance the efficiency of SRTM DEM in flood modeling

    Science.gov (United States)

    Chen, Huili; Liang, Qiuhua; Liu, Yong; Xie, Shuguang

    2018-04-01

    Digital Elevation Model (DEM) is one of the most important controlling factors determining the simulation accuracy of hydraulic models. However, the currently available global topographic data is confronted with limitations for application in 2-D hydraulic modeling, mainly due to the existence of vegetation bias, random errors and insufficient spatial resolution. A hydraulic correction method (HCM) for the SRTM DEM is proposed in this study to improve modeling accuracy. Firstly, we employ the global vegetation corrected DEM (i.e. Bare-Earth DEM), developed from the SRTM DEM to include both vegetation height and SRTM vegetation signal. Then, a newly released DEM, removing both vegetation bias and random errors (i.e. Multi-Error Removed DEM), is employed to overcome the limitation of height errors. Last, an approach to correct the Multi-Error Removed DEM is presented to account for the insufficiency of spatial resolution, ensuring flow connectivity of the river networks. The approach involves: (a) extracting river networks from the Multi-Error Removed DEM using an automated algorithm in ArcGIS; (b) correcting the location and layout of extracted streams with the aid of Google Earth platform and Remote Sensing imagery; and (c) removing the positive biases of the raised segment in the river networks based on bed slope to generate the hydraulically corrected DEM. The proposed HCM utilizes easily available data and tools to improve the flow connectivity of river networks without manual adjustment. To demonstrate the advantages of HCM, an extreme flood event in Huifa River Basin (China) is simulated on the original DEM, Bare-Earth DEM, Multi-Error removed DEM, and hydraulically corrected DEM using an integrated hydrologic-hydraulic model. A comparative analysis is subsequently performed to assess the simulation accuracy and performance of four different DEMs and favorable results have been obtained on the corrected DEM.

  15. Isolated rib fractures in geriatric patients

    Directory of Open Access Journals (Sweden)

    Elmistekawy Elsayed

    2007-01-01

    Full Text Available Introduction: The goal of this study was to investigate the short-term outcomes in patients older than 60 years with isolated rib fractures and admitted to emergency hospital. Materials and Methods: This study included patients who were 60 years old or more and sustained blunt chest injury and had isolated rib fractures. The following data were obtained from the medical records: age, gender, number of fracture ribs, side of fracture ribs, mechanism and nature of injury, preexisting medical conditions, complications, admission to intensive care unit (ICU, need for mechanical ventilation, length of ICU and hospital stay and mortality. Results: For the study, 39 patients who were 60 years old or more and admitted to the hospital because of isolated rib fractures were enrolled. There were 28 males (71.7% and 11 females (28.3% with mean age of (66.84 ± 4.7 years. No correlation was found between comorbidities and hospital outcomes except in those who were diabetic (P-value = 0.005 and those with chronic lung disease (P-value = 0.006. Pulmonary complications were the most frequent complications encountered in those patients. Pulmonary complications were: lung contusion in 8 patients (20.5% and pulmonary infection in 6 patients (15.8%. Conclusion: Elderly patients sustaining blunt chest trauma had significant morbidity and potential for mortality.

  16. Automatic diameter control system applied to the laser heated pedestal growth technique

    Directory of Open Access Journals (Sweden)

    Andreeta M.R.B.

    2003-01-01

    Full Text Available We described an automatic diameter control system (ADC, for the laser heated pedestal growth technique, that reduces the diameter fluctuations in oxide fibers grown from unreacted and non-sinterized pedestals, to less than 2% of the average fiber diameter, and diminishes the average diameter fluctuation, over the entire length of the fiber, to less than 1%. The ADC apparatus is based on an artificial vision system that controls the pulling speed and the height of the molten zone within a precision of 30 mum. We also show that this system can be used for periodic in situ axial doping the fiber. Pure and Cr3+ doped LaAlO3 and pure LiNbO3 were usedas model materials.

  17. An analysis of 214 cases of rib fractures

    Directory of Open Access Journals (Sweden)

    Sule Karadayi

    2011-01-01

    Full Text Available INTRODUCTION: Rib fractures are the most common type of injury associated with trauma to the thorax. In this study, we investigated whether morbidity and mortality rates increased in correlation with the number of fractured ribs. MATERIALS AND METHODS: Data from 214 patients with rib fractures who applied or were referred to our clinic between January 2007 and December 2008 were retrospectively evaluated. The patients were allocated into three groups according to the number of fractures: 1 patients with an isolated rib fracture (RF1 (n = 50, 23.4%, 2 patients with two rib fractures (RF2 (n = 53, 24.8%, and 3 patients with more than two rib fractures (RF3 (n = 111, 51.9%. The patients were evaluated and compared according to the number of rib fractures, mean age, associated chest injuries (hemothorax, pneumothorax, and/or pulmonary contusion, and co-existing injuries to other systems. FINDINGS: The mean age of the patients was 51.5 years. The distribution of associated chest injuries was 30% in group RF1, 24.6% in group RF2, and 75.6% in group RF3 (p<0.05. Co-existing injuries to other systems were 24% in group RF1, 23.2% in group RF2, and 52.6% in group RF3 (p<0.05. Two patients (4% in group RF1, 2 patients (3.8% in group RF2, and 5 patients (4.5% in group RF3 (total n = 9; 4.2% died. CONCLUSION: Patients with any number of rib fractures should be carefully screened for co-existing injuries in other body systems and hospitalized to receive proper treatment.

  18. Clinical Utility of Chest Computed Tomography in Patients with Rib Fractures CT Chest and Rib Fractures

    OpenAIRE

    Chapman, Brandon C.; Overbey, Douglas M.; Tesfalidet, Feven; Schramm, Kristofer; Stovall, Robert T.; French, Andrew; Johnson, Jeffrey L.; Burlew, Clay C.; Barnett, Carlton; Moore, Ernest E.; Pieracci, Fredric M.

    2016-01-01

    Background Chest CT is more sensitive than a chest X-ray (CXR) in diagnosing rib fractures; however, the clinical significance of these fractures remains unclear. Objectives The purpose of this study was to determine the added diagnostic use of chest CT performed after CXR in patients with either known or suspected rib fractures secondary to blunt trauma. Methods Retrospective coho...

  19. Single crystalline silicon solar cells with rib structure

    Directory of Open Access Journals (Sweden)

    Shuhei Yoshiba

    2017-02-01

    Full Text Available To improve the conversion efficiency of Si solar cells, we have developed a thin Si wafer-based solar cell that uses a rib structure. The open-circuit voltage of a solar cell is known to increase with deceasing wafer thickness if the cell is adequately passivated. However, it is not easy to handle very thin wafers because they are brittle and are subject to warpage. We fabricated a lattice-shaped rib structure on the rear side of a thin Si wafer to improve the wafer’s strength. A silicon nitride film was deposited on the Si wafer surface and patterned to form a mask to fabricate the lattice-shaped rib, and the wafer was then etched using KOH to reduce the thickness of the active area, except for the rib region. Using this structure in a Si heterojunction cell, we demonstrated that a high open-circuit voltage (VOC could be obtained by thinning the wafer without sacrificing its strength. A wafer with thickness of 30 μm was prepared easily using this structure. We then fabricated Si heterojunction solar cells using these rib wafers, and measured their implied VOC as a function of wafer thickness. The measured values were compared with device simulation results, and we found that the measured VOC agrees well with the simulated results. To optimize the rib and cell design, we also performed device simulations using various wafer thicknesses and rib dimensions.

  20. The population distribution of the sagittal abdominal diameter (SAD) and SAD/height ratio among Finnish adults.

    Science.gov (United States)

    Kahn, H S; Rissanen, H; Bullard, K M; Knekt, P

    2014-12-01

    Sagittal abdominal diameter (SAD; 'abdominal height' measured in supine position) may improve upon conventional anthropometry for predicting incident cardiometabolic diseases. However, the SAD is used infrequently by practitioners and epidemiologists. A representative survey of Finnish adults in 2000-2001 collected body measurements including SAD (by sliding-beam calliper) using standardized protocols. Sampled non-pregnant adults (ages 30+ years; 79% participation) provided 6123 SAD measurements from 80 health centre districts. Through stratified, complex survey design, these data represented 2.86 million adults at ages 30+ years. SAD ranged from 13.5 to 38.0 cm, with a population mean (standard error) of 21.7 (0.05) cm and median (interquartile range) of 21.0 (19.1-23.4). Median SAD was higher at ages 50+ years compared with ages 30-49 both for men (22.4 [20.5-24.6] vs. 20.8 [19.3-22.7]) and women (21.7 [19.6-23.9] vs. 19.4 [17.8-21.4]). The SAD/height ratio was similar (0.118) for both sexes at 30-39 years, rising more steeply with age for women than men. Attaining only a basic education, compared with a high level, was associated with increased mean (95% confidence interval) SADs for men (22.6 [22.3-22.8] vs. 22.0 [21.7-22.2]) and women (21.8 [21.5-22.0] vs. 20.6 [20.4-20.8]). Finland's early experience with nationally representative SAD measurements provides normative reference values and physiological insights useful for investigations of cardiometabolic risk. © 2014 World Obesity.

  1. Analysis of bone healing in flail chest injury: do we need to fix both fractures per rib?

    Science.gov (United States)

    Marasco, Silvana; Liew, Susan; Edwards, Elton; Varma, Dinesh; Summerhayes, Robyn

    2014-09-01

    Surgical rib fixation (SRF) for severe rib fracture injuries is generating increasing interest in the medical literature. It is well documented that poorly healed fractured ribs can lead to chronic pain, disability, and deformity. An unanswered question in SRF for flail chest injury is whether it is sufficient to fix one fracture per rib, on successive ribs, thus converting a flail chest injury into simple fractured ribs, or whether both ends of the floating segment of the chest wall should be fixed. This study aimed to analyze SRF in flail chest injury, assessing 3-month outcomes for nonfixed fractured rib ends in the flail segment. This is a retrospective review (2005-2013) of 60 consecutive patients who underwent SRF for flail chest injury admitted to the Alfred Hospital, Melbourne, Australia. Imaging by three-dimensional computed tomography (3D CT) of the chest at admission was compared with follow-up 3D CT at 3 months after injury. The 3-month CT scans were assessed for degree of healing and presence of residual deformity at the fracture fixation site. Follow-up CT was performed in 52 of the 60 patients. At 3 months after surgery, 86.5% of the patients had at least partial healing with good alignment and adequate fracture stabilization. Hardware failure was noted in five patients (9.6%) and occurred with the absorbable prostheses only. Six patients who had preoperative overlapping or displacement showed no improvement in deformity despite fixing the lateral fractures. Callus formation and bony bridging between adjacent ribs was often noted in the rib fractures not fixed (28 of 52 patients, 54%) This retrospective review of 3D CT chest at 3 months after rib fixation indicates that a philosophy of fixing only one fracture per rib in a flail segment does not avoid deformity and displacement, particularly in posterior rib fractures. Therapeutic study, level V; epidemiologic study, level V.

  2. Major Co-localized QTL for Plant Height, Branch Initiation Height, Stem Diameter, and Flowering Time in an Alien Introgression Derived Brassica napus DH Population

    Directory of Open Access Journals (Sweden)

    Yusen Shen

    2018-03-01

    Full Text Available Plant height (PH, branch initiation height (BIH, and stem diameter (SD are three stem-related traits that play crucial roles in plant architecture and lodging resistance. Herein, we show one doubled haploid (DH population obtained from a cross between Y689 (one Capsella bursa-pastoris derived Brassica napus intertribal introgression and Westar (B. napus cultivar that these traits were significantly positively correlated with one another and with flowering time (FT. Based on a high-density SNP map, a total of 102 additive quantitative trait loci (QTL were identified across six environments. Seventy-two consensus QTL and 49 unique QTL were identified using a two-round strategy of QTL meta-analysis. Notably, a total of 19 major QTL, including 11 novel ones, were detected for these traits, which comprised two QTL clusters on chromosomes A02 and A07. Conditional QTL mapping was performed to preliminarily evaluate the genetic basis (pleiotropy or tight linkage of the co-localized QTL. In addition, QTL by environment interactions (QEI mapping was performed to verify the additive QTL and estimate the QEI effect. In the genomic regions of all major QTL, orthologs of the genes involved in phytohormone biosynthesis, phytohormone signaling, flower development, and cell differentiation in Arabidopsis were proposed as candidate genes. Of these, BnaA02g02560, an ortholog of Arabidopsis GASA4, was suggested as a candidate gene for PH, SD, and FT; and BnaA02g08490, an ortholog of Arabidopsis GNL, was associated with PH, BIH and FT. These results provide useful information for further genetic studies on stem-related traits and plant growth adaptation.

  3. Microbiological Safety of Commercial Prime Rib Preparation Methods: Thermal Inactivation of Salmonella in Mechanically Tenderized Rib Eye.

    Science.gov (United States)

    Calle, Alexandra; Porto-Fett, Anna C S; Shoyer, Bradley A; Luchansky, John B; Thippareddi, Harshavardhan

    2015-12-01

    Boneless beef rib eye roasts were surface inoculated on the fat side with ca. 5.7 log CFU/g of a five-strain cocktail of Salmonella for subsequent searing, cooking, and warm holding using preparation methods practiced by restaurants surveyed in a medium-size Midwestern city. A portion of the inoculated roasts was then passed once through a mechanical blade tenderizer. For both intact and nonintact roasts, searing for 15 min at 260°C resulted in reductions in Salmonella populations of ca. 0.3 to 1.3 log CFU/g. For intact (nontenderized) rib eye roasts, cooking to internal temperatures of 37.8 or 48.9°C resulted in additional reductions of ca. 3.4 log CFU/g. For tenderized (nonintact) rib eye roasts, cooking to internal temperatures of 37.8 or 48.9°C resulted in additional reductions of ca. 3.1 or 3.4 log CFU/g, respectively. Pathogen populations remained relatively unchanged for intact roasts cooked to 37.8 or 48.9°C and for nonintact roasts cooked to 48.9°C when held at 60.0°C for up to 8 h. In contrast, pathogen populations increased ca. 2.0 log CFU/g in nonintact rib eye cooked to 37.8°C when held at 60.0°C for 8 h. Thus, cooking at low temperatures and extended holding at relatively low temperatures as evaluated herein may pose a food safety risk to consumers in terms of inadequate lethality and/or subsequent outgrowth of Salmonella, especially if nonintact rib eye is used in the preparation of prime rib, if on occasion appreciable populations of Salmonella are present in or on the meat, and/or if the meat is not cooked adequately throughout.

  4. Plastic bowing of the ribs in children

    Energy Technology Data Exchange (ETDEWEB)

    Caro, P.A.; Borden, S. IV

    1988-06-01

    Four cases of plastic bowing of the ribs are presented. In three patients with Werdnig-Hoffman disease, plastic curvatures were associated with chronic pneumonia and atelectasis. We postulate that intrapulmonary retractive forces can deform ribs thinned by muscular atrophy. In turn, thoracic collapse can perpetuate lobar and segmental atelectasis. In one case of osteogenesis imperfecta without pneumonia, we believe normal muscle forces bent ribs weakened by deficiency of normal cortical architecture.

  5. Epidural Analgesia after Rib Fractures.

    Science.gov (United States)

    Zaw, Andrea A; Murry, Jason; Hoang, David; Chen, Kevin; Louy, Charles; Bloom, Matthew B; Melo, Nicolas; Alban, Rodrigo F; Margulies, Daniel R; Ley, Eric J

    2015-10-01

    Pain associated with rib fractures impairs respiratory function and increases pulmonary morbidity. The purpose of this study was to determine how epidural catheters alter mortality and complications in trauma patients. We performed a retrospective study involving adult blunt trauma patients with moderate-to-severe injuries from January 1, 2004 to December 31, 2013. During the 10-year period, 526 patients met the inclusion criteria; 43/526 (8%) patients had a catheter placed. Mean age of patients with epidural catheter (CATH) was higher compared with patients without epidural catheter (NOCATH) (54 vs 48 years, P = 0.021), Injury Severity Score was similar (26 CATH vs 27 NOCATH, P = 0.84), and CATH had higher mean rib fractures (7.4 vs 4.1, P ribs fractured. The epidural cohort had longer hospital LOS and decreased mortality. In contrast to other studies, DVT rates were increased in patients who received epidural catheters.

  6. Factors affecting visualization of posterior rib fractures in abused infants

    International Nuclear Information System (INIS)

    Kleinman, P.K.; Adams, V.I.; Blackbourne, B.D.; Marks, S.C.

    1987-01-01

    Rib fractures in abused infants commonly occur in the posterior rib arcs. Fractures occurring near the costovertebral articulations are usually identified radiographically only once callus has formed. To assess the factors influencing the visibility of fractures near the costovertical articulations, the authors studied 103 posterior rib fractures occurring in 16 abused infants. Radiologic findings were correlated with CT findings and pathologic material from nine ribs in four patients. The limited visibility of fractures relates to (1) the frequent superimposition of the transverse process over the rib fracture site, (2) a fracture line that crosses at an obliquity to the x-ray beam, and (3) nondisplacement of rib fragments due to preservation of the posterior periosteum. Fresh rib fractures invisible on a frontal projection may be clearly defined on axial CT scans, or on postmortem radiographs. A knowledge of the factors influencing the visibility of these important injuries is useful in planning an appropriate diagnostic evaluation of suspected infant abuse

  7. Effect of soil properties on Hydraulic characteristics under subsurface drip irrigation

    Science.gov (United States)

    Fan, Wangtao; Li, Gang

    2018-02-01

    Subsurface drip irrigation (SDI) is a technique that has a high potential in application because of its high efficiency in water-saving. The hydraulic characteristics of SDI sub-unit pipe network can be affected by soil physical properties as the emitters are buried in soils. The related research, however, is not fully explored. The laboratory tests were carried out in the present study to determine the effects of hydraulic factors including operating pressure, initial soil water content, and bulk density on flow rate and its sensitivity to each hydraulic factor for two types of SDI emitters (PLASSIM emitter and Heping emitter). For this purpose, three soils with contrasting textures (i.e., light sand, silt loam, and light clay) were repacked with two soil bulk density (1.25 and1.40 g cm-3) with two initial soil water content (12% and 18%) in plexiglass columns with 40 cm in diameter and 40 cm in height. Drip emitters were buried at depth of 20 cm to measure the flow rates under seven operating pressures (60, 100, 150, 200, 250, 300, and 370 kPa). We found that the operating pressure was the dominating factor of flow rate of the SDI emitter, and flow rate increased with the increase of operating pressure. The initial soil water content and bulk density also affected the flow rate, and their effects were the most notable in the light sand soil. The sensitivity of flow rate to each hydraulic factor was dependent on soil texture, and followed a descending order of light sand>silt loam>light clay for both types of emitters. Further, the sensitivity of flow rate to each hydraulic factor decreased with the increase of operating pressure, initial soil water content, and bulk density. This study may be used to guide the soil specific-design of SDI emitters for optimal water use and management.

  8. Lower thoracic rib stress fractures in baseball pitchers.

    Science.gov (United States)

    Gerrie, Brayden J; Harris, Joshua D; Lintner, David M; McCulloch, Patrick C

    2016-01-01

    Stress fractures of the first rib on the dominant throwing side are well-described in baseball pitchers; however, lower thoracic rib fractures are not commonly recognized. While common in other sports such as rowing, there is scant literature on these injuries in baseball. Intercostal muscle strains are commonly diagnosed in baseball pitchers and have a nearly identical presentation but also a highly variable healing time. The diagnosis of a rib stress fracture can predict a more protracted recovery. This case series presents two collegiate baseball pitchers on one team during the same season who were originally diagnosed with intercostal muscle strains, which following magnetic resonance imaging (MRI) were found to have actually sustained lower thoracic rib stress fractures. The first sustained a stress fracture of the posterior aspect of the right 8th rib on the dominant arm side, while the second presented with a left-sided 10th rib stress fracture on the nondominant arm side. In both cases, MRI was used to visualize the fractures as plain radiographs are insensitive and commonly negative early in patient presentation. Patients were treated with activity modification, and symptomatic management for 4-6 weeks with a graduated return to throwing and competition by 8-10 weeks. The repetitive high stresses incurred by pitching may cause either dominant or nondominant rib stress fractures and this should be included in the differential diagnosis of thoracic injuries in throwers. It is especially important that athletic trainers and team physicians consider this diagnosis, as rib fractures may have a protracted course and delayed return to play. Additionally, using the appropriate imaging techniques to establish an accurate diagnosis can help inform return-to-play decisions, which have important practical applications in baseball, such as roster management and eligibility.

  9. Comparison of ultrasonography and radiography in diagnosis of rib fractures.

    Science.gov (United States)

    Pishbin, Elham; Ahmadi, Koorosh; Foogardi, Molood; Salehi, Maryam; Seilanian Toosi, Farrokh; Rahimi-Movaghar, Vafa

    2017-08-01

    Rib fractures are the most common skeletal thoracic injuries resulting from blunt chest trauma. Half of the rib fractures are not detected upon a precise physical evaluation and radiographs. Recently ultrasonography (USG) has been investigated to detect rib fractures. But based on literature the usefulness of USG varies widely. This study was conducted to investigate the role of USG in the detection of possible rib fractures in comparison with radiography. In this cross-sectional study, consecutive patients with minor blunt chest trauma and suspected rib fractures presenting in Imam Reza Hospital located in Mashhad-Iran, between April 2013 and October 2013 were assessed by USG and radiography. The radiography was performed in a posteroanterior (PA) chest projection and oblique rib view centered over the area of trauma. The time duration spent in taking USG and radiography were recorded. The prevalence and location of fractures revealed by USG and radiography were compared. Sixty-one suspected patients were assessed. The male to female ratio was 2.4:1 (43 men and 18 women) with a mean ± SD age of (44.3 ± 19.7) years. There were totally 59 rib fractures in 38 (62.3%) patients based on radiography and USG, while 23 (37.7%) patients had no diagnostic evidence of rib lesions. USG revealed 58 rib fractures in 33 (54.1%) of 61 suspected patients and radiographs revealed 32 rib fractures in 20 (32.8%) of 61 patients. A total of 58 (98.3%) rib fractures were detected by USG, whereas oblique rib view and PA chest radiography showed 27 (45.8%) and 24 (40.7%) rib fractures, respectively. The average duration of USG was (12 ± 3) min (range 7-17 min), whereas the duration of radiography was (27 ± 6) min (range 15-37 min). The kappa coefficient showed a low level of agreement between both USG and PA chest radiography (kappa coefficient = 0.28), and between USG and oblique rib view (kappa coefficient = 0.32). USG discloses more fractures than radiography in

  10. PICTORIAL INTERLUDE Beware the bifid rib!

    African Journals Online (AJOL)

    be associated with Gorlin-Goltz basal cell nevus syndrome, a rare autosomal dominant condition characterised by multiple nevoid basal cell carcinomas, jaw cysts and bifid ribs. Further features include other rib anomalies, deficiency of the lateral clavicle, mandibular hypoplasia, macrocephaly and mental retardation.1.

  11. Plastic bowing of the ribs in children

    International Nuclear Information System (INIS)

    Caro, P.A.; Borden, S. IV

    1988-01-01

    Four cases of plastic bowing of the ribs are presented. In three patients with Werdnig-Hoffman disease, plastic curvatures were associated with chronic pneumonia and atelectasis. We postulate that intrapulmonary retractive forces can deform ribs thinned by muscular atrophy. In turn, thoracic collapse can perpetuate lobar and segmental atelectasis. In one case of osteogenesis imperfecta without pneumonia, we believe normal muscle forces bent ribs weakened by deficiency of normal cortical architecture. (orig.)

  12. Stress injury of the rib in a swimmer

    Energy Technology Data Exchange (ETDEWEB)

    Heincelman, Carrie [University of Cincinnati Medical Center, Department of Orthopaedic Surgery, Cincinnati, OH (United States); Brown, Seth; England, Eric; Mehta, Kaushal; Wissman, Robert D. [University of Cincinnati Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2014-09-15

    Rib stress injuries are uncommonly reported but have been documented among athletes, most notably rowers. There have only been two prior case reports of rib stress injuries in swimmers, both of which were young females. Magnetic resonance (MR) imaging was either not obtained or the imaging characteristics were incompletely described. We present a case of an isolated third rib stress injury in a collegiate male swimmer diagnosed via MR imaging. We briefly discuss the possible etiologies for rib stress injuries, their MR appearance, as well as their treatment. (orig.)

  13. Rib fracture following stereotactic body radiotherapy: a potential pitfall.

    Science.gov (United States)

    Stanic, Sinisa; Boike, Thomas P; Rule, William G; Timmerman, Robert D

    2011-11-01

    Although the incidence of rib fractures after conventional radiotherapy is generally low (rib fractures are a relatively common complication of stereotactic body radiotherapy. For malignancy adjacent to the chest wall, the incidence of rib fractures after stereotactic body radiotherapy is as high as 10%. Unrecognized bone fractures can mimic bone metastases on bone scintigraphy, can lead to extensive workup, and can even lead to consideration of unnecessary systemic chemotherapy, as treatment decisions can be based on imaging findings alone. Nuclear medicine physicians and diagnostic radiologists should always consider rib fracture in the differential diagnosis.

  14. Delayed pneumothorax complicating minor rib fracture after chest trauma.

    Science.gov (United States)

    Lu, Ming-Shian; Huang, Yao-Kuang; Liu, Yun-Hen; Liu, Hui-Ping; Kao, Chiung-Lun

    2008-06-01

    Pneumothorax (PTX) after trauma is a preventable cause of death. Drainage procedures such as chest tube insertion have been traditionally advocated to prevent fatal tension PTX. We evaluated the safety of close observation in patients with delayed PTX complicating rib fracture after minor chest trauma. Adult patients (>18 years) with a diagnosis of chest trauma and 3 or fewer fractured ribs were reviewed. Case patients were divided according to age, location and number of fractured ribs, mechanism of trauma, and initial pulmonary complication after thoracic trauma for comparative analysis. There were 207 male (70.2%) and 88 female (29.8%) patients whose ages ranged from 18 to 93 years (median, 55 years). The mechanisms of trauma were a motor vehicle accident in 207 patients, falls in 66, pedestrian injury in 10, and assaults in 14. Ninety-five patients sustained 1 rib fracture, 95 had 2 rib fractures, and 105 suffered 3 rib fractures. Right-sided injury occurred in 164 cases, left-sided injury did in 127, and bilateral injury did in 4. The most frequent location of rib fractures was from the fourth rib to the ninth rib. The initial pulmonary complications after trauma were PTX in 16 patients, hemothorax in 43, pneumohemothorax in 14, lung contusion in 75, and isolated subcutaneous emphysema (SubcEmph) in 33. Thirty percent of the patients (n = 5/16) who presented with traumatic PTX were observed safely without drainage. Delayed PTX was recorded in 16 patients, occurring mostly during the first 2 days of their admission. Associated extrathoracic injury was recorded in 189 patients. The mean hospital stay of the patients was 7.66 days. Longer hospital stay was related to increasing number of fractured ribs, need for thoracic drainage, and the presence of associated extrathoracic injury. The mortality rate for the entire group was 2%. The presence of SubcEmph was the only risk factor associated with the development of delayed PTX. Patients sustaining blunt chest

  15. Assessment and management of rib fracture pain in geriatric population: an ode to old age.

    Science.gov (United States)

    Wardhan, Richa

    2013-10-01

    Pain management for traumatic rib fractures has been described in literature, but there is paucity of data when it comes to acute pain management in the elderly, let alone pain resulting from traumatic rib fractures. This article focuses on challenges of assessment of pain in elderly patients and the various options available for pain management including utilization of nerve blocks. Nerve blocks are instrumental in treating rib fracture pain along with utilization of opioids and nonopioids thus formulating a multimodal approach to pain management. The goal is to devise a proper pain management regimen for geriatric patients with rib fractures to decrease the morbidity and mortality associated with it. Developing institutional protocols is one step forward towards quality care for such patients.

  16. Determinants of rib motion in flail chest.

    Science.gov (United States)

    Cappello, M; Legrand, A; De Troyer, A

    1999-03-01

    We have previously developed a canine model of isolated flail chest to assess the effects of this condition on the mechanics of breathing, and these studies have led to the conclusion that the respiratory displacement of the fractured ribs is primarily determined by the fall in pleural pressure (Delta Ppl) and the action of the parasternal intercostal muscles. The present studies were designed to test the validity of this conclusion. A flail was induced in six supine anesthetized animals by fracturing both dorsally and ventrally the second to fifth ribs on the right side of the chest, after which the phrenic nerve roots were bilaterally sectioned in the neck. Sectioning the phrenic nerves caused a 34% decrease in Delta Ppl, associated with a 39% increase in parasternal intercostal inspiratory EMG activity (p Delta Ppl during the subsequent inspiration, all animals again showed a clear-cut inward rib displacement. These observations therefore confirm that in dogs with flail chest, the inspiratory displacement of the fractured ribs is set by the balance between the force related to pleural pressure and that generated by the parasternal intercostals. These observations also point to the critical importance of the pattern of inspiratory muscle activation in determining the magnitude of rib cage paradox in such patients.

  17. Bifid rib – usefulness of chest ultrasound. A case report

    Directory of Open Access Journals (Sweden)

    Magdalena Kryger

    2013-12-01

    Full Text Available The paper presents the possibility of using ultrasonography in the diagnosis of a congenital rib anomaly in the form of bifid rib. Bifid rib is a rare congenital abnormality of anterior chest wall. It manifests as a chest “lump.” Such lesions are detected during a routine physical examination or chest X-ray which is often performed for other reasons. The overall prevalence of bifid rib is estimated at 0.15% to 3.4% (mean 2% and it accounts for approximately 20% of all congenital rib anomalies. It is usually an unilateral lesion. The cases presented herein constitute the first pediatric cases in the available literature in which bifid rib anomaly was visualized by ultrasound examination.

  18. The relationship between reference canopy conductance and simplified hydraulic architecture

    Science.gov (United States)

    Novick, Kimberly; Oren, Ram; Stoy, Paul; Juang, Jehn-Yih; Siqueira, Mario; Katul, Gabriel

    2009-06-01

    Terrestrial ecosystems are dominated by vascular plants that form a mosaic of hydraulic conduits to water movement from the soil to the atmosphere. Together with canopy leaf area, canopy stomatal conductance regulates plant water use and thereby photosynthesis and growth. Although stomatal conductance is coordinated with plant hydraulic conductance, governing relationships across species has not yet been formulated at a practical level that can be employed in large-scale models. Here, combinations of published conductance measurements obtained with several methodologies across boreal to tropical climates were used to explore relationships between canopy conductance rates and hydraulic constraints. A parsimonious hydraulic model requiring sapwood-to-leaf area ratio and canopy height generated acceptable agreement with measurements across a range of biomes (r2=0.75). The results suggest that, at long time scales, the functional convergence among ecosystems in the relationship between water-use and hydraulic architecture eclipses inter-specific variation in physiology and anatomy of the transport system. Prognostic applicability of this model requires independent knowledge of sapwood-to-leaf area. In this study, we did not find a strong relationship between sapwood-to-leaf area and physical or climatic variables that are readily determinable at coarse scales, though the results suggest that climate may have a mediating influence on the relationship between sapwood-to-leaf area and height. Within temperate forests, canopy height alone explained a large amount of the variance in reference canopy conductance (r2=0.68) and this relationship may be more immediately applicable in the terrestrial ecosystem models.

  19. An analysis of 214 cases of rib fractures

    OpenAIRE

    Karadayi, Sule; Nadir, Aydin; Sahin, Ekber; Celik, Burcin; Arslan, Sulhattin; Kaptanoglu, Melih

    2011-01-01

    INTRODUCTION: Rib fractures are the most common type of injury associated with trauma to the thorax. In this study, we investigated whether morbidity and mortality rates increased in correlation with the number of fractured ribs. MATERIALS AND METHODS: Data from 214 patients with rib fractures who applied or were referred to our clinic between January 2007 and December 2008 were retrospectively evaluated. The patients were allocated into three groups according to the number of fractures: 1) p...

  20. Numerical Predictions of Enhanced Impingement Jet Cooling with Ribs and Pins in Co-Flow and Cross-Flow Configurations

    Directory of Open Access Journals (Sweden)

    A. M. El-Jummah

    2017-02-01

    Full Text Available Numerical calculations relevant to gas turbine internal wall heat transfer cooling were conducted using conjugate heat transfer (CHT computational Fluid Dynamics (CFD commercial codes. The CHT CFD predictions were carried out for impingement heat transfer with different types of obstacle walls (fins on the target surfaces. A 10 × 10 row of impingement air jet holes (or hole density n of 4306 m-2 was used, which gives ten rows of holes in the cross-flow direction and only one heat transfer enhancement obstacle per impingement jet was investigated. Previously, four different shaped obstacles were investigated experimentally and were used to validate the present predictions. The obstacle walls, which were equally spaced on the centreline between each impingement jet are of the co-flow and cross-flow configurations. The impingement jet pitch X to diameter D, X/D and gap Z to diameter, Z/D ratios were kept constant at 4.66 and 3.06 for X, Z and D of 15.24, 10.00 and 3.27 mm, respectively. The obstacles investigated were ribs and rectangular pin-fins shapes, using two obstacles height H to diameter, H/D ratio of 1.38 and 2.45. Computations were carried out for three different mass flux G of 1.08, 1.48 and 1.94 kg/sm2. Relative pressure loss ∆P/P and surface average heat transfer coefficient (HTC h predictions for the range of G, showed good agreement with the experimental results. The prediction also reveals that obstacles not only increases the turbulent flows, but also takes away most of the cooling heat transfer that produces the regions with highest thermal gradients. It also reduces the impingement gap downstream cross-flow.

  1. Changes in wood density, wood anatomy and hydraulic properties of the xylem along the root-to-shoot flow path in tropical rainforest trees.

    Science.gov (United States)

    Schuldt, Bernhard; Leuschner, Christoph; Brock, Nicolai; Horna, Viviana

    2013-02-01

    It is generally assumed that the largest vessels are occurring in the roots and that vessel diameters and the related hydraulic conductance in the xylem are decreasing acropetally from roots to leaves. With this study in five tree species of a perhumid tropical rainforest in Sulawesi (Indonesia), we searched for patterns in hydraulic architecture and axial conductivity along the flow path from small-diameter roots through strong roots and the trunk to distal sun-canopy twigs. Wood density differed by not more than 10% across the different flow path positions in a species, and branch and stem wood density were closely related in three of the five species. Other than wood density, the wood anatomical and xylem hydraulic traits varied in dependence on the position along the flow path, but were unrelated to wood density within a tree. In contrast to reports from conifers and certain dicotyledonous species, we found a hump-shaped variation in vessel diameter and sapwood area--specific conductivity along the flow path in all five species with a maximum in the trunk and strong roots and minima in both small roots and twigs; the vessel size depended on the diameter of the organ. This pattern might be an adaptation to the perhumid climate with a low risk of hydraulic failure. Despite a similar mean vessel diameter in small roots and twigs, the two distal organs, hydraulically weighted mean vessel diameters were on average 30% larger in small roots, resulting in ∼ 85% higher empirical and theoretical specific conductivities. Relative vessel lumen area in percent of sapwood area decreased linearly by 70% from roots to twigs, reflecting the increase in sclerenchymatic tissue and tracheids in acropetal direction in the xylem. Vessel size was more closely related to the organ diameter than to the distance along the root-to-shoot flow path. We conclude that (i) the five co-occurring tree species show convergent patterns in their hydraulic architecture despite different growth

  2. Association of Ipsilateral Rib Fractures With Displacement of Midshaft Clavicle Fractures.

    Science.gov (United States)

    Stahl, Daniel; Ellington, Matthew; Brennan, Kindyle; Brennan, Michael

    2017-04-01

    To determine whether the presence of ipsilateral rib fractures affects the rate of a clavicle fracture being unstable (>100% displacement). A retrospective review from 2002-2013 performed at a single level 1 trauma center evaluated 243 midshaft clavicle fractures. Single Level 1 trauma center. These fractures were subdivided into those with ipsilateral rib fractures (CIR; n = 149) and those without ipsilateral rib fractures (CnIR; n = 94). The amount of displacement was measured on the initial injury radiograph and subsequent follow-up radiographs. Fractures were classified into either 100% displacement, based on anteroposterior radiographs. Ipsilateral rib fractures were recorded based on which number rib was fractured and the total number of fractured ribs. One hundred sixteen (78%) of the CIR group and 51 (54%) of the CnIR group were found to have >100% displacement at follow-up (P = 0.0047). Seventy-two percent of the CIR group demonstrated progression from 100% displacement of the fracture compared with only 54% of the CnIR group (P fracture to >100% was 4.08 (P = 0.000194) when ribs 1-4 were fractured and not significant for rib fractures 5-8 or 9-12. The presence of concomitant ipsilateral rib fractures significantly increases the rate of midshaft clavicle fractures being >100% displaced. In addition, a fracture involving the upper one-third of the ribs significantly increases the rate of the clavicle fracture being >100% displaced on early follow-up. Clavicle fractures with associated ipsilateral rib fractures tend to demonstrate an increased amount of displacement on follow-up radiographs compared with those without ipsilateral rib fractures. Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.

  3. Less-invasive stabilization of rib fractures by intramedullary fixation: a biomechanical evaluation.

    Science.gov (United States)

    Bottlang, Michael; Helzel, Inga; Long, William; Fitzpatrick, Daniel; Madey, Steven

    2010-05-01

    This study evaluated intramedullary fixation of rib fractures with Kirschner wires and novel ribs splints. We hypothesized that rib splints can provide equivalent fixation strength while avoiding complications associated with Kirschner wires, namely wire migration and cutout. The durability, strength, and failure modes of rib fracture fixation with Kirschner wires and rib splints were evaluated in 22 paired human ribs. First, intact ribs were loaded to failure to determine their strength. After fracture fixation with Kirschner wires and rib splints, fixation constructs were dynamically loaded to 360,000 cycles at five times the respiratory load to determine their durability. Finally, constructs were loaded to failure to determine residual strength and failure modes. All constructs sustained dynamic loading without failure. Dynamic loading caused three times more subsidence in Kirschner wire constructs (1.2 mm +/- 1.4 mm) than in rib splint constructs (0.4 mm +/- 0.2 mm, p = 0.09). After dynamic loading, rib splint constructs remained 48% stronger than Kirschner wire constructs (p = 0.001). Five of 11 Kirschner wire constructs failed catastrophically by cutting through the medial cortex, leading to complete loss of stability and wire migration through the lateral cortex. The remaining six constructs failed by wire bending. Rib splint constructs failed by development of fracture lines along the superior and interior cortices. No splint construct failed catastrophically, and all splint constructs retained functional reduction and fixation. Because of their superior strength and absence of catastrophic failure mode, rib splints can serve as an attractive alternative to Kirschner wires for intramedullary stabilization of rib fractures, especially in the case of posterior rib fractures where access for plating is limited.

  4. Rib cage pain

    Science.gov (United States)

    ... any of the following: Bruised, cracked, or fractured rib Inflammation of cartilage near the ... the best cures for a ribcage fracture . Follow your health care provider's instructions for treating ...

  5. Secondary left ventricular injury with haemopericardium caused by a rib fracture after blunt chest trauma

    Directory of Open Access Journals (Sweden)

    Somsekhar Ganti

    2006-03-01

    Full Text Available Abstract Trauma is the third most common cause of death in the West. In the US, approximately 90,000 deaths annually are traumatic in nature and over 75% of casualties from blunt trauma are due to chest injuries. Cardiac injuries from rib fractures following blunt trauma are extremely rare. We report the unusual case of a patient who fell from a height and presented with haemopericardium and haemothorax as a result of left ventricular and lingular lacerations and was sucessfully operated upon.

  6. Numerical investigations of rib fracture failure models in different dynamic loading conditions.

    Science.gov (United States)

    Wang, Fang; Yang, Jikuang; Miller, Karol; Li, Guibing; Joldes, Grand R; Doyle, Barry; Wittek, Adam

    2016-01-01

    Rib fracture is one of the most common thoracic injuries in vehicle traffic accidents that can result in fatalities associated with seriously injured internal organs. A failure model is critical when modelling rib fracture to predict such injuries. Different rib failure models have been proposed in prediction of thorax injuries. However, the biofidelity of the fracture failure models when varying the loading conditions and the effects of a rib fracture failure model on prediction of thoracic injuries have been studied only to a limited extent. Therefore, this study aimed to investigate the effects of three rib failure models on prediction of thoracic injuries using a previously validated finite element model of the human thorax. The performance and biofidelity of each rib failure model were first evaluated by modelling rib responses to different loading conditions in two experimental configurations: (1) the three-point bending on the specimen taken from rib and (2) the anterior-posterior dynamic loading to an entire bony part of the rib. Furthermore, the simulation of the rib failure behaviour in the frontal impact to an entire thorax was conducted at varying velocities and the effects of the failure models were analysed with respect to the severity of rib cage damages. Simulation results demonstrated that the responses of the thorax model are similar to the general trends of the rib fracture responses reported in the experimental literature. However, they also indicated that the accuracy of the rib fracture prediction using a given failure model varies for different loading conditions.

  7. A hydraulic hybrid propulsion method for automobiles with self-adaptive system

    International Nuclear Information System (INIS)

    Wu, Wei; Hu, Jibin; Yuan, Shihua; Di, Chongfeng

    2016-01-01

    A hydraulic hybrid vehicle with the self-adaptive system is proposed. The mode-switching between the driving mode and the hydraulic regenerative braking mode is realised by the pressure cross-feedback control. Extensive simulated and tested results are presented. The control parameters are reduced and the energy efficiency can be increased by the self-adaptive system. The mode-switching response is fast. The response time can be adjusted by changing the controlling spool diameter of the hydraulic operated check valve in the self-adaptive system. The closing of the valve becomes faster with a smaller controlling spool diameter. The hydraulic regenerative braking mode can be achieved by changing the hydraulic transformer controlled angle. Compared with the convention electric-hydraulic system, the self-adaptive system for the hydraulic hybrid vehicle mode-switching has a higher reliability and a lower cost. The efficiency of the hydraulic regenerative braking is also increased. - Highlights: • A new hybrid system with a self-adaptive system for automobiles is presented. • The mode-switching is realised by the pressure cross-feedback control. • The energy efficiency can be increased with the self-adaptive system. • The control parameters are reduced with the self-adaptive system.

  8. Case report: clinical and postmortem findings in four cows with rib fracture

    OpenAIRE

    Braun, Ueli; Warislohner, Sonja; Hetzel, Udo; Nuss, Karl

    2017-01-01

    BACKGROUND: Published reports of rib fractures in adult cattle are limited to the occurrence of chronic rib swellings caused by calluses, which are unremarkable from a clinical standpoint, whereas studies identifying clinical signs of rib fractures were not found in a literature search. This report describes the clinical and postmortem findings in four cows with rib fractures. CASE PRESENTATION: The 13th rib was fractured in three cows and the 11th rib in the remaining cow; three fractures...

  9. Radiation Induced Rib Fractures on Bone Scan after Breast Cancer Surgery and Radiation Therapy

    International Nuclear Information System (INIS)

    Kim, Hae Won; Won, Kyoung Sook; Zeon, Seok Kil; Kim, Jin Hee

    2009-01-01

    This study is to evaluate rib fractures on bone scan in breast cancer patients treated with breast cancer surgery and radiation therapy and to evaluate its relation with radiation therapy and operation modality. Two hundred seventy cases that underwent serial bone scan after breast cancer surgery and radiation therapy were enrolled. Bone scan and chest CT findings of rib fracture were analyzed. The rib uptake was seen in 74 of 270 cases (27.4%) on bone scan and 50 cases (18.5%) were confirmed to have rib fracture by chest CT. The rate of modified radical mastectomy in patients with rib fracture was significantly higher than that in patients without rib fracture (66.0% vs. 27.0%, p=0.000). The rate of additional radiation therapy to axillar or supraclavicular regions in patients with rib fracture was significantly higher than that in patients without rib fracture (62.0% vs. 28.6%, p=0.000). Rib fracture was seen most frequently at 1-2 years after radiation therapy (51.9%) and single rib fracture was seen most frequently (55.2%). Of total 106 rib fractures, focal rib uptake was seen in 94 ribs (88.7%) and diffuse rib uptake was seen in 12 ribs (11.3%). On one year follow-up bone scan, complete resolution of rib uptake was seen in 15 ribs (14.2%). On chest CT, the rate of fracture line in ribs with intense uptake was significantly higher than that in ribs with mild or moderate uptake (p=0.000). The rate of presence of fracture line in ribs with focal uptake was significantly higher than that in ribs with diffuse uptake (p=0.001). Rib fracture in breast cancer patients after radiation therapy was related to radiation portal and operation modality. It should be interpreted carefully as a differential diagnosis of bone metastasis

  10. Radiation Induced Rib Fractures on Bone Scan after Breast Cancer Surgery and Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hae Won; Won, Kyoung Sook; Zeon, Seok Kil; Kim, Jin Hee [Keimyung University, School of Medicine, Daegu (Korea, Republic of)

    2009-08-15

    This study is to evaluate rib fractures on bone scan in breast cancer patients treated with breast cancer surgery and radiation therapy and to evaluate its relation with radiation therapy and operation modality. Two hundred seventy cases that underwent serial bone scan after breast cancer surgery and radiation therapy were enrolled. Bone scan and chest CT findings of rib fracture were analyzed. The rib uptake was seen in 74 of 270 cases (27.4%) on bone scan and 50 cases (18.5%) were confirmed to have rib fracture by chest CT. The rate of modified radical mastectomy in patients with rib fracture was significantly higher than that in patients without rib fracture (66.0% vs. 27.0%, p=0.000). The rate of additional radiation therapy to axillar or supraclavicular regions in patients with rib fracture was significantly higher than that in patients without rib fracture (62.0% vs. 28.6%, p=0.000). Rib fracture was seen most frequently at 1-2 years after radiation therapy (51.9%) and single rib fracture was seen most frequently (55.2%). Of total 106 rib fractures, focal rib uptake was seen in 94 ribs (88.7%) and diffuse rib uptake was seen in 12 ribs (11.3%). On one year follow-up bone scan, complete resolution of rib uptake was seen in 15 ribs (14.2%). On chest CT, the rate of fracture line in ribs with intense uptake was significantly higher than that in ribs with mild or moderate uptake (p=0.000). The rate of presence of fracture line in ribs with focal uptake was significantly higher than that in ribs with diffuse uptake (p=0.001). Rib fracture in breast cancer patients after radiation therapy was related to radiation portal and operation modality. It should be interpreted carefully as a differential diagnosis of bone metastasis.

  11. Comparison of ultrasonography and radiography in diagnosis of rib fractures

    OpenAIRE

    Pishbin, Elham; Ahmadi, Koorosh; Foogardi, Molood; Salehi, Maryam; Seilanian Toosi, Farrokh; Rahimi-Movaghar, Vafa

    2017-01-01

    Purpose: Rib fractures are the most common skeletal thoracic injuries resulting from blunt chest trauma. Half of the rib fractures are not detected upon a precise physical evaluation and radiographs. Recently ultrasonography (USG) has been investigated to detect rib fractures. But based on literature the usefulness of USG varies widely. This study was conducted to investigate the role of USG in the detection of possible rib fractures in comparison with radiography. Methods: In this cross-s...

  12. Clinical and Radiologic Predictive Factors of Rib Fractures in Outpatients With Chest Pain.

    Science.gov (United States)

    Zhang, Liang; McMahon, Colm J; Shah, Samir; Wu, Jim S; Eisenberg, Ronald L; Kung, Justin W

    To identify the clinical and radiologic predictive factors of rib fractures in stable adult outpatients presenting with chest pain and to determine the utility of dedicated rib radiographs in this population of patients. Following Institutional Review Board approval, we performed a retrospective review of 339 consecutive cases in which a frontal chest radiograph and dedicated rib series had been obtained for chest pain in the outpatient setting. The frontal chest radiograph and dedicated rib series were sequentially reviewed in consensus by two fellowship-trained musculoskeletal radiologists blinded to the initial report. The consensus interpretation of the dedicated rib series was used as the gold standard. Multiple variable logistic regression analysis assessed clinical and radiological factors associated with rib fractures. Fisher exact test was used to assess differences in medical treatment between the 2 groups. Of the 339 patients, 53 (15.6%) had at least 1 rib fracture. Only 20 of the 53 (37.7%) patients' fractures could be identified on the frontal chest radiograph. The frontal chest radiograph had a sensitivity of 38% and specificity of 100% when using the rib series as the reference standard. No pneumothorax, new mediastinal widening or pulmonary contusion was identified. Multiple variable logistic regression analysis of clinical factors associated with the presence of rib fractures revealed a significant association of trauma history (odds ratio 5.7 [p rib fractures in this population demonstrated a significant association of pleural effusion with rib fractures (odds ratio 18.9 [p rib fractures received narcotic analgesia in 47.2% of the cases, significantly more than those without rib fractures (21.3%, p rib fractures have a higher association with a history of minor trauma and age ≥40 in the adult population. Radiographic findings associated with rib fractures include pleural effusion. The frontal chest radiograph alone has low sensitivity in

  13. Rib fractures: comparison of associated injuries between pediatric and adult population.

    Science.gov (United States)

    Kessel, Boris; Dagan, Jasmin; Swaid, Forat; Ashkenazi, Itamar; Olsha, Oded; Peleg, Kobi; Givon, Adi; Alfici, Ricardo

    2014-11-01

    Rib fractures are considered a marker of exposure to significant traumatic energy. In children, because of high elasticity of the chest wall, higher energy levels are necessary for ribs to fracture. The purpose of this study was to analyze patterns of associated injuries in children as compared with adults, all of whom presented with rib fractures. A retrospective cohort study involving blunt trauma patients with rib fractures registered in the National Trauma Registry was conducted. Of 6,995 trauma victims who were found to suffer from rib fractures, 328 were children and 6,627 were adults. Isolated rib fractures without associated injuries occurred in 19 children (5.8%) and 731 adults (11%). More adults had 4 or more fractured ribs compared with children (P pneumothorax (P = .006), spleen, and liver injury (P < .001). Mortality rate was 5% in both groups. The incidence of associated head, thoracic, and abdominal solid organ injuries in children was significantly higher than in adults suffering from rib fractures. In spite of a higher Injury Severity Score and incidence of associated injuries, mortality rate was similar. Mortality of rib fracture patients was mostly affected by the presence of extrathoracic injuries. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Surgical Treatment of Snapping Scapula Syndrome Due to Malunion of Rib Fractures.

    Science.gov (United States)

    Ten Duis, Kaj; IJpma, Frank F A

    2017-02-01

    This report describes a case of snapping scapula syndrome (SSS) caused by malunited rib fractures. Abrasion of the deformed ribs was performed with good results. SSS as a cause of shoulder pain after thoracic trauma has to be considered and can be treated by a surgical abrasion technique. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. The Vertebral Column, Ribs, and Sternum of the African Giant Rat (Cricetomys gambianus Waterhouse)

    Science.gov (United States)

    Olude, Matthew Ayokunle; Mustapha, Oluwaseun Ahmed; Ogunbunmi, Temitope Kehinde; Olopade, James Olukayode

    2013-01-01

    Examined bones were obtained from eight adult African giant rats, Cricetomys gambianus Waterhouse. Animals used had an average body mass of 730.00 ± 41.91 gm and body length of 67.20 ± 0.05 cm. The vertebral formula was found to be C7, T13, L6, S4, Ca31–36. The lowest and highest points of the cervicothoracic curvature were at C5 and T2, respectively. The spinous process of the axis was the largest in the cervical group while others were sharp and pointed. The greatest diameter of the vertebral canal was at the atlas (0.8 cm) and the lowest at the caudal sacral bones (2 mm). The diameter of the vertebral foramen was the largest at C1 and the smallest at the S4; the foramina were negligibly indistinct caudal to the sacral vertebrae. There were 13 pairs of ribs. The first seven pairs were sternal, and six pairs were asternal of which the last 2-3 pairs were floating ribs. The sternum was composed of deltoid-shaped manubrium sterni, four sternebrae, and a slender processus xiphoideus. No sex-related differences were observed. The vertebral column is adapted for strong muscular attachment and actions helping the rodent suited for speed, agility, dexterity, and strength which might enable it to overpower prey and escape predation. PMID:24288518

  16. The Vertebral Column, Ribs, and Sternum of the African Giant Rat (Cricetomys gambianus Waterhouse

    Directory of Open Access Journals (Sweden)

    Matthew Ayokunle Olude

    2013-01-01

    Full Text Available Examined bones were obtained from eight adult African giant rats, Cricetomys gambianus Waterhouse. Animals used had an average body mass of 730.00±41.91 gm and body length of 67.20±0.05 cm. The vertebral formula was found to be C7, T13, L6, S4, Ca31–36. The lowest and highest points of the cervicothoracic curvature were at C5 and T2, respectively. The spinous process of the axis was the largest in the cervical group while others were sharp and pointed. The greatest diameter of the vertebral canal was at the atlas (0.8 cm and the lowest at the caudal sacral bones (2 mm. The diameter of the vertebral foramen was the largest at C1 and the smallest at the S4; the foramina were negligibly indistinct caudal to the sacral vertebrae. There were 13 pairs of ribs. The first seven pairs were sternal, and six pairs were asternal of which the last 2-3 pairs were floating ribs. The sternum was composed of deltoid-shaped manubrium sterni, four sternebrae, and a slender processus xiphoideus. No sex-related differences were observed. The vertebral column is adapted for strong muscular attachment and actions helping the rodent suited for speed, agility, dexterity, and strength which might enable it to overpower prey and escape predation.

  17. Radiographic abnormalities of ribs in β-thalassemic children

    International Nuclear Information System (INIS)

    Singcharoen, T.; Piyachon, C.; Kulapongs, P.

    1988-01-01

    Bone change is one of the most outstanding manifestations of marrow hyperplasia in thalassemia patients. In the thorax, marrow hyperplasia widens the ribs, thins the cortices, and erases most of their trabecular patterns. Thus, a variety of radiologic changes of the ribs have been described. The chest radiographs of 33 Thai children with β-thalassemia major were reviewed, and a spectrum of rib changes were observed

  18. Topological and sizing optimization of reinforced ribs for a machining centre

    Science.gov (United States)

    Chen, T. Y.; Wang, C. B.

    2008-01-01

    The topology optimization technique is applied to improve rib designs of a machining centre. The ribs of the original design are eliminated and new ribs are generated by topology optimization in the same 3D design space containing the original ribs. Two-dimensional plate elements are used to replace the optimum rib topologies formed by 3D rectangular elements. After topology optimization, sizing optimization is used to determine the optimum thicknesses of the ribs. When forming the optimum design problem, multiple configurations of the structure are considered simultaneously. The objective is to minimize rib weight. Static constraints confine displacements of the cutting tool and the workpiece due to cutting forces and the heat generated by spindle bearings. The dynamic constraint requires the fundamental natural frequency of the structure to be greater than a given value in order to reduce dynamic deflection. Compared with the original design, the improvement resulting from this approach is significant.

  19. Relationships between stem diameter at breast height (DBH), tree ...

    African Journals Online (AJOL)

    buba

    amount of light that the tree intercepts for photosynthesis. The tree stem size has its ... the amount of solar radiation intercepted by a tree. (Tanka, 2006). .... 7. Stem Diameter. C ro w n le n g th. Figure 2. Graph of the relationship between stem dbh vs. crown crown length. 0.7. 0.6. 0.5. 0.4. 0.3. 15. 14. 13. 12. 11. 10. 9. 8. 7. 6. 5.

  20. The Place of Ultrasonography in the Evaluation of Rib Fractures

    Directory of Open Access Journals (Sweden)

    Fulya Bakılan

    2015-12-01

    Full Text Available Objective: The aim of this study was to investigate whether ultrasonography is superior to chest x-ray in detecting rib fractures in patients with minor blunt chest trauma and chest pain. Materials and Methods: Ultrasonography findings of 32 patients with minor blunt chest trauma showing no evidence of a rib fracture on anteroposterior chest x-rays, were documented. Presence of cortical discontinuities, acoustic shadows, reverberation artifacts, and hematoma by ultrasonography was proposed as the diagnostic criteria for detecting the rib fracture. Results: Rib fracture was detected in 20 patients (62.5% according to ultrasonography results. A mildly displaced fracture was detected in 7 patients (35%, hematoma was detected in 3 patients (15% and multiple fractures (in 5th, 6th, 7th, and 8th ribs were detected in 1 patient (5%. Conclusion: The results of our study showed that ultrasonography is superior to chest x-ray, in detecting rib fractures.

  1. Reduction of rib fractures with a bioresorbable plating system: preliminary observations.

    Science.gov (United States)

    Vu, Kim-Chi; Skourtis, Mia E; Gong, Xi; Zhou, Minhao; Ozaki, Wayne; Winn, Shelley R

    2008-05-01

    Operative fixation of rib fractures can reduce morbidity and mortality. Currently, resorbable fixation devices are used in a variety of surgical procedures. A standard osteotomy was prepared in 30 New Zealand white rabbits at the 12th rib. Eighteen had surgical repair with bioresorbable plates and 12 underwent nonoperative management. Half the animals in each group were killed at 3-week postfracture and the remaining animals were killed at 6-week postfracture. Ribs were radiographed and processed histologically to assess fracture healing. Rib reduction was defined as the alignment of the rib ends in a structural condition similar to the prefractured state and quantitative radiomorphometry measured the radiopaque callus surrounding the rib injury sites. Statistical analysis was performed using Fisher's exact test and an unpaired Student's t test and significance was established at p rib fractures remained reduced in the operative group, whereas zero of six and three of six of the rib fractures remained reduced, respectively, in the nonoperative group. A statistically significant increase in radiopaque callus surrounding the rib injury sites was observed at 3 and 6 weeks in the fixed groups. Fixation of rib fractures with a bioresorbable miniplate system was superior to nonoperative treatment at the 3-week interval, with a statistically significant increase in radiopaque callus formation at both 3 and 6 weeks. Additional studies will evaluate the biomechanical outcomes and degradation tissue response after extended in vivo intervals.

  2. The use of nylon cable ties to repair rib fractures in neonatal foals

    OpenAIRE

    Downs, Chris; Rodgerson, Dwayne

    2011-01-01

    Commercially available nylon cable ties were used as a method of internal fixation for displaced rib fractures in 8 equine neonates. The procedure was effective, well-tolerated, rapid, and inexpensive. The use of nylon cable ties as internal fixation for displaced rib fractures in foals is an effective surgical procedure.

  3. Comparative study between rib imaging of DR dual energy subtraction technology and chest imaging

    International Nuclear Information System (INIS)

    Yu Jianming; Lei Ziqiao; Kong Xiangchuang

    2006-01-01

    Objective: To investigate the application value of DR dual energy subtraction technology in rib lesions. Methods: 200 patients were performed with chest DR dual energy subtraction, comparing the rib imaging between DR of thorax and chest imaging using ROC analysis. Results: Among the total of 200 patients, there are 50 cases of rib calcification, 7 cases of rib destruction, 22 cases of rib fracture. The calcification, destruction and fracture were displayed respectively by ribs below diaphragm and rib markings. The analytic parameter of rib imaging of DR dual energy subtraction Az is 0.9367, while that of rib imaging of chest Az is 0.6830. Conclusion: DR dual energy subtraction technology is superior to chest imaging in the displaying of rib lesion and ribs below diaphragm. (authors)

  4. Tissue engineering rib with the incorporation of biodegradable polymer cage and BMSCs/decalcified bone: an experimental study in a canine model.

    Science.gov (United States)

    Tang, Hua; Wu, Bin; Qin, Xiong; Zhang, Lu; Kretlow, Jim; Xu, Zhifei

    2013-05-20

    The reconstruction of large bone defects, including rib defects, remains a challenge for surgeons. In this study, we used biodegradable polydioxanone (PDO) cages to tissue engineer ribs for the reconstruction of 4cm-long costal defects. PDO sutures were used to weave 6cm long and 1cm diameter cages. Demineralized bone matrix (DBM) which is a xenograft was molded into cuboids and seeded with second passage bone marrow mesenchymal stem cells (BMSCs) that had been osteogenically induced. Two DBM cuboids seeded with BMSCs were put into the PDO cage and used to reconstruct the costal defects. Radiographic examination including 3D reconstruction, histologic examination and mechanical test was performed after 24 postoperative weeks. All the experimental subjects survived. In all groups, the PDO cage had completely degraded after 24 weeks and been replaced by fibrous tissue. Better shape and radian were achieved in PDO cages filled with DBM and BMSCs than in the other two groups (cages alone, or cages filled with acellular DBM cuboids). When the repaired ribs were subjected to an outer force, the ribs in the PDO cage/DBMs/BMSCs group kept their original shape while ribs in the other two groups deformed. In the PDO cage/DBMs/BMSCs groups, we also observed bony union at all the construct interfaces while there was no bony union observed in the other two groups. This result was also confirmed by radiographic and histologic examination. This study demonstrates that biodegradable PDO cage in combination with two short BMSCs/DBM cuboids can repair large rib defects. The satisfactory repair rate suggests that this might be a feasible approach for large bone repair.

  5. Effect of tank geometry on its average performance

    Science.gov (United States)

    Orlov, Aleksey A.; Tsimbalyuk, Alexandr F.; Malyugin, Roman V.; Leontieva, Daria A.; Kotelnikova, Alexandra A.

    2018-03-01

    The mathematical model of non-stationary filling of vertical submerged tanks with gaseous uranium hexafluoride is presented in the paper. There are calculations of the average productivity, heat exchange area, and filling time of various volumes tanks with smooth inner walls depending on their "height : radius" ratio as well as the average productivity, degree, and filling time of horizontal ribbing tank with volume 6.10-2 m3 with change central hole diameter of the ribs. It has been shown that the growth of "height / radius" ratio in tanks with smooth inner walls up to the limiting values allows significantly increasing tank average productivity and reducing its filling time. Growth of H/R ratio of tank with volume 1.0 m3 to the limiting values (in comparison with the standard tank having H/R equal 3.49) augments tank productivity by 23.5 % and the heat exchange area by 20%. Besides, we have demonstrated that maximum average productivity and a minimum filling time are reached for the tank with volume 6.10-2 m3 having central hole diameter of horizontal ribs 6.4.10-2 m.

  6. Quality of life after major trauma with multiple rib fractures.

    Science.gov (United States)

    Marasco, Silvana; Lee, Geraldine; Summerhayes, Robyn; Fitzgerald, Mark; Bailey, Michael

    2015-01-01

    Rib fractures are a common injury presenting to major trauma centres and community hospitals. Aside from the acute impact of rib fracture injury, longer-term morbidity of pain, disability and deformity have been described. Despite this, the mainstay of management for the vast majority of rib fracture injuries remains supportive only with analgesia and where required respiratory support. This study aimed to document the long-term quality of life in a cohort of major trauma patients with rib fracture injury over 24 months. Retrospective review (July 2006-July 2011) of 397 major trauma patients admitted to The Alfred Hospital with rib fractures and not treated with operative rib fixation. The main outcome measures were quality of life over 24 months post injury assessed using the Glasgow Outcome Scale Extended and SF12 health assessment forms and a pain questionnaire. Assessment over 24 months of major trauma patients with multiple rib fractures demonstrated significantly lower quality of life compared with published Australian norms at all time points measured. Return to work rates were poor with only 71% of those who were working prior to their accident, returning to any work. This study demonstrates a significant reduction in quality of life for rib fracture patients requiring admission to hospital, which does not return to the level of Australian norms for at least two years. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  7. Thermal Hydraulic Integral Effect Tests for Pressurized Water Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Baek, W. P.; Song, C. H.; Kim, Y. S. and others

    2005-02-15

    The objectives of the project are to construct a thermal-hydraulic integral effect test facility and to perform various integral effect tests for design, operation, and safety regulation of pressurized water reactors. During the first phase of this project (1997.8{approx}2002.3), the basic technology for thermal-hydraulic integral effect tests was established and the basic design of the test facility was accomplished: a full-height, 1/300-volume-scaled full pressure facility for APR1400, an evolutionary pressurized water reactor that was developed by Korean industry. Main objectives of the present phase (2002.4{approx}2005.2), was to optimize the facility design and to construct the experimental facility. We have performed following researches: 1) Optimization of the basic design of the thermal-hydraulic integral effect test facility for PWRs - ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation) - Reduced height design for APR1400 (+ specific design features of KSNP safety injection systems) - Thermal-hydraulic scaling based on three-level scaling methodology by Ishii et al. 2) Construction of the ATLAS facility - Detailed design of the test facility - Manufacturing and procurement of components - Installation of the facility 3) Development of supporting technology for integral effect tests - Development and application of advanced instrumentation technology - Preliminary analysis of test scenarios - Development of experimental procedures - Establishment and implementation of QA system/procedure.

  8. Case report 467: Cystic chondroblastoma left 4th rib

    Energy Technology Data Exchange (ETDEWEB)

    Sundaram, M.; McGuire, M.H.; Naunheim, K.; Schajowicz, F.

    1988-03-01

    A case of chondroblastoma in an 18-year-old female arising from a rib near the costotransverse articulation (presumably from the epiphysis of the articular process) has been described. The destructive pattern noted in the rib, associated with a large soft tissue mass, favored a malignant lesion rather than a benign one. Histologically, this tumor had large cystic and hemorrhagic components, consistent with the diagnosis of a cystic chondroblastoma of a rib. Curiously, this patient, like two others with chondroblastoma in a rib was asymptomatic, and attention to the abnormality was drawn from a routine chest radiography. The patient remains disease-free one and a half-years following surgery.

  9. Case report: clinical and postmortem findings in four cows with rib fracture.

    Science.gov (United States)

    Braun, Ueli; Warislohner, Sonja; Hetzel, Udo; Nuss, Karl

    2017-02-06

    Published reports of rib fractures in adult cattle are limited to the occurrence of chronic rib swellings caused by calluses, which are unremarkable from a clinical standpoint, whereas studies identifying clinical signs of rib fractures were not found in a literature search. This report describes the clinical and postmortem findings in four cows with rib fractures. The 13th rib was fractured in three cows and the 11th rib in the remaining cow; three fractures were on the right and one on the left side. Clinical and postmortem findings varied considerably, and percussion of the rib cage elicited a pain response in only one cow. One cow had generalised peritonitis because of perforation of the rumen by the fractured rib. One cow was recumbent because of pain and became a downer cow, and two other cows had bronchopneumonia, which was a sequel to osteomyelitis of the fracture site in one. In the absence of a history of trauma, the diagnosis of rib fracture based on clinical signs alone is difficult. Although rib fractures undoubtedly are very painful, the four cases described in this report suggest that they are difficult to diagnose in cattle because associated clinical signs are nonspecific.

  10. Various appearances of rib companion shadow mimicking a pathologic condition

    International Nuclear Information System (INIS)

    Choi, Yo Won; Yoo, Shi Joon; Im, Jung Gil

    1992-01-01

    We have observed that the companion shadow of the upper rib may be misinterpreted as a small pneumothorax or pleural plaque associated with asbestosis. To observe the radiographic characteristics of the normal companion shadow, we analyzed, on the posteroanterior(PA) chest radiographs, the companion shadow of 50 normal cases. Factors such as occurrence on each rib, the sharpness of the margin, the relative position to the rib, the shape and the thickness were observed. Also, we analyzed the displaced pleura of 4 pneumothorax cases to differentiate their findings from the findings of normal companion shadows. On 50 normal chest radiographs, 192 companion shadows were observed on the first to fourth ribs. In 173 of those shadows, the visceral margin of the companion shadow on the second rib simulated pneumothorax more closely than those on any other ribs due to its apical location and thinness. In six of 50 normal cases, the companion shadow in the first or second rib showed an inwardly convex lower margin, mimicking pleural plaque. The companion shadow was suggested on the plain chest radiograph by the following characteristics imultiplicity (47/50), thicker than normal pleura (3/4), persistent on serial films with the same shape and specific location(4/4)

  11. Fatigue strength of the joint between diaphragms and longitudinal ribs in box section girders; Hako danmen keta no diaphragm to shita flange tateribu no kosabu no hiro kyodo

    Energy Technology Data Exchange (ETDEWEB)

    Miki, C.; Shiozaki, M.; Takeishi, K. [Tokyo Institute of Technology, Tokyo (Japan). Faculty of Engineering; Ohashi, H. [Honshu-Shikoku Bridge Authority, Tokyo (Japan)

    1997-04-21

    Discussions were given on crossing joints of diaphragms on hanger fixing sections and U-ribs on lower flanges in reinforcing box girders of a suspension bridge, as to their local stress generating behavior and effects of cope holes on fatigue strength. The test pieces have dimensions and shapes modeling the crossing joints, and the steel materials are SM490YA for upper and lower flanges and webs, and SS400 for U-ribs. The loading test was performed with four-point bending and at loading amplitudes of 30 to 45 tf. Furthermore, stress analysis was conducted by using the finite element method. The following conclusions were obtained as a result: local stress at cope hole tips decreases and fatigue strength increases with the smaller the cope hole diameter; when the cope holes are back-filled completely, deformation is concentrated on welds of the U-ribs and the flanges, generating high local stress; this reduces significantly the fatigue strength of details having no cope holes; and no particular differences are found on effects of boxing of the cope hole tips on the fatigue strength. 7 refs., 10 figs., 3 tabs.

  12. Automatic three-dimensional rib centerline extraction from CT scans for enhanced visualization and anatomical context

    Science.gov (United States)

    Ramakrishnan, Sowmya; Alvino, Christopher; Grady, Leo; Kiraly, Atilla

    2011-03-01

    We present a complete automatic system to extract 3D centerlines of ribs from thoracic CT scans. Our rib centerline system determines the positional information for the rib cage consisting of extracted rib centerlines, spinal canal centerline, pairing and labeling of ribs. We show an application of this output to produce an enhanced visualization of the rib cage by the method of Kiraly et al., in which the ribs are digitally unfolded along their centerlines. The centerline extraction consists of three stages: (a) pre-trace processing for rib localization, (b) rib centerline tracing, and (c) post-trace processing to merge the rib traces. Then we classify ribs from non-ribs and determine anatomical rib labeling. Our novel centerline tracing technique uses the Random Walker algorithm to segment the structural boundary of the rib in successive 2D cross sections orthogonal to the longitudinal direction of the ribs. Then the rib centerline is progressively traced along the rib using a 3D Kalman filter. The rib centerline extraction framework was evaluated on 149 CT datasets with varying slice spacing, dose, and under a variety of reconstruction kernels. The results of the evaluation are presented. The extraction takes approximately 20 seconds on a modern radiology workstation and performs robustly even in the presence of partial volume effects or rib pathologies such as bone metastases or fractures, making the system suitable for assisting clinicians in expediting routine rib reading for oncology and trauma applications.

  13. Analysis of pumping tests: Significance of well diameter, partial penetration, and noise

    Science.gov (United States)

    Heidari, M.; Ghiassi, K.; Mehnert, E.

    1999-01-01

    The nonlinear least squares (NLS) method was applied to pumping and recovery aquifer test data in confined and unconfined aquifers with finite diameter and partially penetrating pumping wells, and with partially penetrating piezometers or observation wells. It was demonstrated that noiseless and moderately noisy drawdown data from observation points located less than two saturated thicknesses of the aquifer from the pumping well produced an exact or acceptable set of parameters when the diameter of the pumping well was included in the analysis. The accuracy of the estimated parameters, particularly that of specific storage, decreased with increases in the noise level in the observed drawdown data. With consideration of the well radii, the noiseless drawdown data from the pumping well in an unconfined aquifer produced good estimates of horizontal and vertical hydraulic conductivities and specific yield, but the estimated specific storage was unacceptable. When noisy data from the pumping well were used, an acceptable set of parameters was not obtained. Further experiments with noisy drawdown data in an unconfined aquifer revealed that when the well diameter was included in the analysis, hydraulic conductivity, specific yield and vertical hydraulic conductivity may be estimated rather effectively from piezometers located over a range of distances from the pumping well. Estimation of specific storage became less reliable for piezemeters located at distances greater than the initial saturated thickness of the aquifer. Application of the NLS to field pumping and recovery data from a confined aquifer showed that the estimated parameters from the two tests were in good agreement only when the well diameter was included in the analysis. Without consideration of well radii, the estimated values of hydraulic conductivity from the pumping and recovery tests were off by a factor of four.The nonlinear least squares method was applied to pumping and recovery aquifer test data in

  14. Experimental and numerical analysis of interlocking rib formation at sheet metal blanking

    Science.gov (United States)

    Bolka, Špela; Bratuš, Vitoslav; Starman, Bojan; Mole, Nikolaj

    2018-05-01

    Cores for electrical motors are typically produced by blanking of laminations and then stacking them together, with, for instance, interlocking ribs or welding. Strict geometrical tolerances, both on the lamination and on the stack, combined with complex part geometry and harder steel strip material, call for use of predictive methods to optimize the process before actual blanking to reduce the costs and speed up the process. One of the major influences on the final stack geometry is the quality of the interlocking ribs. A rib is formed in one step and joined with the rib of the preceding lamination in the next. The quality of the joint determines the firmness of the stack and also influences its. The geometrical and positional accuracy is thus crucial in rib formation process. In this study, a complex experimental and numerical analysis of interlocking rib formation has been performed. The aim of the analysis is to numerically predict the shape of the rib in order to perform a numerical simulation of the stack formation in the next step of the process. A detailed experimental research has been performed in order to characterize influential parameters on the rib formation and the geometry of the ribs itself, using classical and 3D laser microscopy. The formation of the interlocking rib is then simulated using Abaqus Explicit. The Hilll 48 constitutive material model is based on extensive and novel material characterization process, combining data from in-plane and out-of-plane material tests to perform a 3D analysis of both, rib formation and rib joining. The study shows good correlation between the experimental and numerical results.

  15. Tree Hydraulics: How Sap Rises

    Science.gov (United States)

    Denny, Mark

    2012-01-01

    Trees transport water from roots to crown--a height that can exceed 100 m. The physics of tree hydraulics can be conveyed with simple fluid dynamics based upon the Hagen-Poiseuille equation and Murray's law. Here the conduit structure is modelled as conical pipes and as branching pipes. The force required to lift sap is generated mostly by…

  16. Analysis of in-R12 CHF data: influence of hydraulic diameter and heating length; test of Weisman boiling crisis model; Analyse de donnees de flux critique en R12: influence du diametre hydraulique et de la longueur chauffante; test du modele de Weisman

    Energy Technology Data Exchange (ETDEWEB)

    Czop, V; Herer, C; Souyri, A; Garnier, J

    1993-09-01

    In order to progress on the comprehensive modelling of the boiling crisis phenomenon, Electricite de France (EDF), Commissariat a l`Energie Atomique (CEA) and FRAMATOME have set up experimental programs involving in-R12 tests: the EDF APHRODITE program and the CEA-EDF-FRAMATOME DEBORA program. The first phase in these programs aims to acquire critical heat flux (CHF) data banks, within large thermal-hydraulic parameter ranges, both in cylindrical and annular configurations, and with different hydraulic diameters and heating lengths. Actually, three data banks have been considered in the analysis, all of them concerning in-R12 round tube tests: - the APHRODITE data bank, obtained at EDF with a 13 mn inside diameter, - the DEBORA data bank, obtained at CEA with a 19.2 mm inside diameter, - the KRISTA data bank, obtained at KfK with a 8 mm inside diameter. The analysis was conducted using CHF correlations and with the help of an advanced mathematical tool using pseudo-cubic thin plate type Spline functions. Two conclusions were drawn: -no influence of the heating length on our CHF results, - the influence of the diameter on the CHF cannot be simply expressed by an exponential function of this parameter, as thermal-hydraulic parameters also have an influence. Some calculations with Weisman and Pei theoretical boiling crisis model have been compared to experimental values: fairly good agreement was obtained, but further study must focus on improving the modelling of the influence of pressure and mass velocity. (authors). 12 figs., 4 tabs., 21 refs.

  17. Effect of Tube Diameter on Heat Transfer to Vertically Upward Flowing Supercritical CO2

    International Nuclear Information System (INIS)

    Kang, Deog Ji; Kim, Sin; Bae, Yoon Yeong; Kim, Hwan Yeol; Kim, Hyung Rae

    2007-01-01

    Heat transfer characteristics of supercritical carbon dioxide are being investigated experimentally in the test loop named as SPHINX(Supercritical Pressure Heat Transfer Investigation for NeXt generation) at KAERI. The main purpose of the experiment is to provide a reliable heat transfer database for a SCWR (SuperCritical Water-cooled Reactor) by a prudent extension of the carbon dioxide test results to the estimation of a heat transfer for water. The produced data will be used in the thermo-hydraulic design of core and safety analysis for SCWR. The aim of the present paper is to study the influence of a tube diameter on a heat transfer. The experiments were completed for tubes of an inside diameter of 4.4mm and 9.0mm, respectively. The heat transfer characteristics from the two tubes of different diameters were compared and discussed

  18. Theoretical study of hydraulic jump during circular horizontal hot leg injection in pressurized water reactor

    International Nuclear Information System (INIS)

    El Hawary, Shehab; Abu-Elyazeed, Osayed S.M.; Fahmy, Adel Alyan; Meglaa, Khairy

    2016-01-01

    Highlights: • The model is developed to predict the occurrence of onset hydraulic jump in a circular pipe. • Theoretical results are in agreement with experimental results and theory. • Effects of diameter of the injection pipe, Froude number and injected coolant mass are studied. - Abstract: One important phenomenon occurring during Loss of Coolant Accident (LOCA) is Counter-Current Flow Limitation (CCFL). The incidence of such CCFL is introduced by the onset of hydraulic jump. In the present work, a one dimensional model was modified to fit circular hot channel. The model was used to study the factors affecting the initial Froude number, the location of the occurrence of the hydraulic jump, and the critical coolant flow depth during circular horizontal hot leg injection in US-APWR Mitsubishi Reactor. The results showed good agreement with published experimental data of the Upper Plenum Test Facility (UPTF) at Mannheim, Germany. It was found that higher injected coolant mass flow rate increases the initial Froude number, the location of the occurrence of the hydraulic jump, and the critical injection depth divided by the diameter of the injection pipe. Such behavior is thought to be due to the increase of the inertia force by increasing of the injected coolant mass flow rate and the inverse of the diameter of the injection pipe. It was found also that, the location of the occurrence of hydraulic jump increases with decreasing load effect. Therefore, these results reveal that the avoidance of CCFL as well as hydraulic jump through hot leg at maximum load can be achieved by decreasing the distance between the injection point and the pressure vessel to below 0.3 m, and with diameter of 4 in (10.16 cm) as the design diameter of the injection pipe in US-APWR Mitsubishi Reactor. Moreover, the maximum critical depth (56 cm) is less than the diameter of the hot leg (78.74 cm) at an injected coolant mass flow of 400 kg/s, and with diameter of 4 in (10.16 cm) as the

  19. Usefulness of Reformatted CT Rib Series in Patients with Thoracic Trauma

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Sung Nam; Park, Seong Hoon; Kim, Na Hyung; Juhng, Seon Kwan; Yoon, Kwon Ha [Dept. of Radiology and Institute for Radiological Imaging Science, Wonkwang University School of Medicine, Iksan (Korea, Republic of); Bang, Dong Ho [Dept. of Radiology, Aerospace Medical Center, Cheongwon (Korea, Republic of)

    2013-01-15

    To assess the value of adding a reformatted computed tomography (CT) rib series to transversely reconstructed CT imaging in the evaluation of rib fractures in patients with suspected traumatic thoracic injuries. One hundred consecutive patients with suspected traumatic thoracic injuries underwent 128-section multi-detector row CT. Transverse CT images with 5-mm-thick sections were reconstructed and rib series were reformatted using isotropic vogel data. Three independent radiologists, who were blinded to the data, interpreted the CT scans at 2 sessions with a 4-week interval between the sessions. Only transverse CT images were reviewed at the first session. At the second session, the CT images were reviewed along with the reformatted CT rib series. The following parameters were analyzed: receiver operating characteristic (Roc) curve, pairwise comparisons of Roc curves, sensitivity, specificity, positive predictive value, and negative predictive value. There were 153 rib fractures in 29 patients. The level of the area under the Roc curve, Az improved for all observers. The diagnostic sensitivity and specificity of each observer tended to improve in the second session. The mean confidence scores for all observers of patients with rib fractures improved significantly in the second session. A reformatted CT rib series together with transverse CT scan is useful for the evaluation of rib fracture.

  20. Rib fractures in trauma patients: does operative fixation improve outcome?

    Science.gov (United States)

    Majak, Peter; Næss, Pål A

    2016-12-01

    Renewed interest in surgical fixation of rib fractures has emerged. However, conservative treatment is still preferred at most surgical departments. We wanted to evaluate whether operative treatment of rib fractures may benefit severely injured patients. Several studies report a reduction in mechanical ventilation time, ICU length of stay (LOS), hospital LOS, pneumonia, need for tracheostomy, pain and costs in operatively treated patients with multiple rib fractures compared with patients treated nonoperatively. Although patient selection and timing of the operation seem crucial for successful outcome, no consensus exists. Mortality reduction has only been shown in a few studies. Most studies are retrospective cohort and case-control studies. Only four randomized control trials exist. Conservative treatment, consisting of respiratory assistance and pain control, is still the treatment of choice in the vast majority of patients with multiple rib fractures. In selected patients, operative fixation of fractured ribs within 72 h postinjury may lead to better outcome. More randomized control trials are needed to further determine who benefits from surgical fixation of rib fractures.

  1. Internal rib structure can be predicted using mathematical models: An anatomic study comparing the chest to a shell dome with application to understanding fractures.

    Science.gov (United States)

    Casha, Aaron R; Camilleri, Liberato; Manché, Alexander; Gatt, Ruben; Attard, Daphne; Gauci, Marilyn; Camilleri-Podesta, Marie-Therese; Mcdonald, Stuart; Grima, Joseph N

    2015-11-01

    The human rib cage resembles a masonry dome in shape. Masonry domes have a particular construction that mimics stress distribution. Rib cortical thickness and bone density were analyzed to determine whether the morphology of the rib cage is sufficiently similar to a shell dome for internal rib structure to be predicted mathematically. A finite element analysis (FEA) simulation was used to measure stresses on the internal and external surfaces of a chest-shaped dome. Inner and outer rib cortical thickness and bone density were measured in the mid-axillary lines of seven cadaveric rib cages using computerized tomography scanning. Paired t tests and Pearson correlation were used to relate cortical thickness and bone density to stress. FEA modeling showed that the stress was 82% higher on the internal than the external surface, with a gradual decrease in internal and external wall stresses from the base to the apex. The inner cortex was more radio-dense, P rib level. The internal anatomical features of ribs, including the inner and outer cortical thicknesses and bone densities, are similar to the stress distribution in dome-shaped structures modeled using FEA computer simulations of a thick-walled dome pressure vessel. Fixation of rib fractures should include the stronger internal cortex. © 2015 Wiley Periodicals, Inc.

  2. Rib fractures after chest physiotherapy for bronchiolitis or pneumonia in infants

    Energy Technology Data Exchange (ETDEWEB)

    Chalumeau, Martin [Service de Pneumologie et d' Allergologie Pediatriques, Hopital Necker-Enfants Malades, Paris (France); Service de Pediatrie, Hopital Saint-Vincent-de-Paul, Paris (France); Foix-l' Helias, Laurence; Scheinmann, Pierre; Zuani, Pierre [Service de Pneumologie et d' Allergologie Pediatriques, Hopital Necker-Enfants Malades, Paris (France); Gendrel, Dominique [Service de Pediatrie, Hopital Saint-Vincent-de-Paul, Paris (France); Ducou-le-Pointe, Hubert [Service de Radiologie, Hopital d' Enfants Armand-Trousseau, Avenue du Docteur Arnold Netter, 75571 Paris Cedex 12 (France)

    2002-09-01

    Heading AbstractBackground. The reported causes of rib fractures in infants are: child abuse, accidental injury, cardiopulmonary resuscitation, bone fragility, birth trauma and severe cough.Objective. To report chest physiotherapy (CPT) as a new cause of rib fractures in five infants.Materials and methods. We retrospectively identified all infants with rib fractures after CPT for bronchiolitis or pneumonia over a 4-year period in two paediatric and one paediatric radiology units in three university hospitals in Paris.Results. Five boys were identified. Their median age was 3 months. None had any other potential cause of rib fractures. The indication for CPT was bronchiolitis in four cases and pneumonia in one. The median number of rib fractures was four (range 1-5). Fractures were located between the 3rd and 8th ribs; they were lateral in four patients and posterior in one; they were unilateral in four patients and bilateral in one. Evolution was favourable in all cases. The prevalence of rib fractures after CPT during the study period was estimated at 1 in 1,000 infants hospitalised for bronchiolitis or pneumonia.Conclusions. CPT should be considered a potential, but very rare cause of rib fractures in infants. It can be of clinical relevance when rib fractures are the only feature suggestive of child abuse. (orig.)

  3. Rib fractures after chest physiotherapy for bronchiolitis or pneumonia in infants

    International Nuclear Information System (INIS)

    Chalumeau, Martin; Foix-l'Helias, Laurence; Scheinmann, Pierre; Zuani, Pierre; Gendrel, Dominique; Ducou-le-Pointe, Hubert

    2002-01-01

    Heading AbstractBackground. The reported causes of rib fractures in infants are: child abuse, accidental injury, cardiopulmonary resuscitation, bone fragility, birth trauma and severe cough.Objective. To report chest physiotherapy (CPT) as a new cause of rib fractures in five infants.Materials and methods. We retrospectively identified all infants with rib fractures after CPT for bronchiolitis or pneumonia over a 4-year period in two paediatric and one paediatric radiology units in three university hospitals in Paris.Results. Five boys were identified. Their median age was 3 months. None had any other potential cause of rib fractures. The indication for CPT was bronchiolitis in four cases and pneumonia in one. The median number of rib fractures was four (range 1-5). Fractures were located between the 3rd and 8th ribs; they were lateral in four patients and posterior in one; they were unilateral in four patients and bilateral in one. Evolution was favourable in all cases. The prevalence of rib fractures after CPT during the study period was estimated at 1 in 1,000 infants hospitalised for bronchiolitis or pneumonia.Conclusions. CPT should be considered a potential, but very rare cause of rib fractures in infants. It can be of clinical relevance when rib fractures are the only feature suggestive of child abuse. (orig.)

  4. The ribs unfolded - a CT visualization algorithm for fast detection of rib fractures: effect on sensitivity and specificity in trauma patients

    International Nuclear Information System (INIS)

    Ringl, Helmut; Lazar, Mathias; Toepker, Michael; Woitek, Ramona; Prosch, Helmut; Asenbaum, Ulrika; Balassy, Csilla; Toth, Daniel; Weber, Michael; Mang, Thomas; Hajdu, Stefan; Soza, Grzegorz; Wimmer, Andreas

    2015-01-01

    To assess a radiologist's detection rate of rib fractures in trauma CT when reading curved planar reformats (CPRs) of the ribs compared to reading standard MPRs. Two hundred and twenty trauma CTs (146 males, 74 females) were retrospectively subjected to a software algorithm to generate CPRs of the ribs. Patients were split into two equal groups. Sixteen patients were excluded due to insufficient segmentation, leaving 107 patients in group A and 97 patients in group B. Two radiologists independently evaluated group A using CPRs and group B using standard MPRs. Two different radiologists reviewed both groups with the inverse methods setting. Results were compared to a standard of reference created by two senior radiologists. The reference standard identified 361 rib fractures in 61 patients. Reading CPRs showed a significantly higher overall sensitivity (P < 0.001) for fracture detection than reading standard MPRs, with 80.9 % (584/722) and 71.5 % (516/722), respectively. Mean reading time was significantly shorter for CPRs (31.3 s) compared to standard MPRs (60.7 s; P < 0.001). Using CPRs for the detection of rib fractures accelerates the reading of trauma patient chest CTs, while offering an increased overall sensitivity compared to conventional standard MPRs. (orig.)

  5. The ribs unfolded - a CT visualization algorithm for fast detection of rib fractures: effect on sensitivity and specificity in trauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Ringl, Helmut; Lazar, Mathias; Toepker, Michael; Woitek, Ramona; Prosch, Helmut; Asenbaum, Ulrika; Balassy, Csilla; Toth, Daniel; Weber, Michael; Mang, Thomas [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Hajdu, Stefan [Medical University of Vienna, Department of Trauma Surgery, Vienna (Austria); Soza, Grzegorz; Wimmer, Andreas [Siemens AG, Healthcare Sector, Computed Tomography, Forchheim (Germany)

    2015-07-15

    To assess a radiologist's detection rate of rib fractures in trauma CT when reading curved planar reformats (CPRs) of the ribs compared to reading standard MPRs. Two hundred and twenty trauma CTs (146 males, 74 females) were retrospectively subjected to a software algorithm to generate CPRs of the ribs. Patients were split into two equal groups. Sixteen patients were excluded due to insufficient segmentation, leaving 107 patients in group A and 97 patients in group B. Two radiologists independently evaluated group A using CPRs and group B using standard MPRs. Two different radiologists reviewed both groups with the inverse methods setting. Results were compared to a standard of reference created by two senior radiologists. The reference standard identified 361 rib fractures in 61 patients. Reading CPRs showed a significantly higher overall sensitivity (P < 0.001) for fracture detection than reading standard MPRs, with 80.9 % (584/722) and 71.5 % (516/722), respectively. Mean reading time was significantly shorter for CPRs (31.3 s) compared to standard MPRs (60.7 s; P < 0.001). Using CPRs for the detection of rib fractures accelerates the reading of trauma patient chest CTs, while offering an increased overall sensitivity compared to conventional standard MPRs. (orig.)

  6. A case of pathological rib fractures: focal osteolysis or osteoporosis?

    Science.gov (United States)

    Vrbanić, T S L; Novak, S; Sestan, B; Tudor, A; Gulan, G

    2008-03-01

    This paper reports on a unique, previously unreported, successful outcome in the case of a patient with focal osteolytic lesions of the ribs as a first sign of osteoporosis. The lesions were detected by chance after acute cough-induced rib fractures were seen on plain chest radiographs. The diagnosis had to be approached as a diagnosis of exclusion since known causes of the osteolytic process had to be eliminated. The authors describe multiple focal osteolytic lesions with rib fractures appearing in a pattern that could be confused with metastases. Laboratory results were normal. Final diagnosis was based on plain radiography, bone scan and bone densitometry. Pharmacomedical treatments for osteoporosis were applied. The patient was observed between the year 2000 and 2005. Five years later radiological and bone scintigraphy revealed resolution of the lesion. We conclude that osteoporosis should be included in the differential diagnosis of asymptomatic focal osteolysis of the ribs with rib fractures as a complication of acute cough. The case suggests that focal osteolytic lesions of the ribs may regress over time and become scintigraphically inactive.

  7. Rib fractures induced by coughing: an unusual cause of acute chest pain.

    Science.gov (United States)

    De Maeseneer, M; De Mey, J; Debaere, C; Meysman, M; Osteaux, M

    2000-03-01

    We report three patients with stress fractures of the ribs induced by coughing. Standard radiographs of the chest and ribs did not reveal evidence of rib fractures in any of the patients. Bone scintigraphy, performed 1 to 2 weeks after initial onset of symptoms, showed a focal area of increased uptake along the chest wall in all cases. Thin section angulated helical CT directly visualized the subtle rib fractures. Initial diagnosis of a cough-induced fracture of the rib may be difficult because of the associated underlying disorder, and unnecessary examinations are commonly performed. Identification of a cough-induced fracture of the rib using helical CT may be clinically important to avoid unnecessary concern and additional examinations.

  8. Rib Fracture Patterns and Radiologic Detection – A Restraint-Based Comparison

    OpenAIRE

    Crandall, Jeff; Kent, Richard; Patrie, James; Fertile, Jay; Martin, Peter

    2000-01-01

    This paper presents a study of the rib fracture patterns generated in simulated frontal collisions and the visibility of the rib fractures on plain film radiographs. Using 29 cadaver subjects, rib fractures were identified on oblique, lateral, and anteroposterior chest films by five radiologists independently and were compared with fractures found during a detailed necropsy. Physical, geometric, and experimental factors demonstrated an influence on the ability of a radiologist to identify rib...

  9. Hydraulic fracture considerations in oil sand overburden dams

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, R.; Madden, B.; Danku, M. [Syncrude Canada Ltd., Fort McMurray, AB (Canada)

    2008-07-01

    This paper discussed hydraulic fracture potential in the dry-filled temporary dams used in the oil sands industry. Hydraulic fractures can occur when reservoir fluid pressures are greater than the minimum stresses in a dam. Stress and strain conditions are influenced by pore pressures, levels of compaction in adjacent fills as well as by underlying pit floor and abutment conditions. Propagation pressure and crack initiation pressures must also be considered in order to provide improved hydraulic fracture protection to dams. Hydraulic fractures typically result in piping failures. Three cases of hydraulic fracture at oil sands operations in Alberta were presented. The study showed that hydraulic fracture failure modes must be considered in dam designs, particularly when thin compacted lift of dry fill are used to replace wetted clay cores. The risk of hydraulic fractures can be reduced by eliminating in situ bedrock irregularities and abutments. Overpressure heights, abutment sloping, and the sloping of fills above abutments, as well as the dam's width and base conditions must also be considered in relation to potential hydraulic fractures. It was concluded that upstream sand beaches and internal filters can help to prevent hydraulic fractures in dams in compacted control zones. 5 refs., 16 figs.

  10. HIGH ASPECT RATIO ION EXCHANGE RESIN BED - HYDRAULIC RESULTS FOR SPERICAL RESIN BEADS

    International Nuclear Information System (INIS)

    Duignan, M; Charles Nash, C; Timothy Punch, T

    2007-01-01

    A principal role of the DOE Savannah River Site is to safely dispose of a large volume of liquid nuclear waste held in many storage tanks. An in-tank ion exchange unit is being considered for cesium removal to accelerate waste processing. This unit is planned to have a relatively high bed height to diameter ratio (10:1). Complicating the design is the need to cool the ion exchange media; therefore, the ion exchange column will have a central cooling core making the flow path annular. To separate cesium from waste the media being considered is made of resorcinol formaldehyde resin deposited on spherical plastic beads and is a substitute for a previously tested resin made of crystalline silicotitanate. This spherical media not only has an advantage of being mechanically robust, but, unlike its predecessor, it is also reusable, that is, loaded cesium can be removed through elution and regeneration. Resin regeneration leads to more efficient operation and less spent resin waste, but its hydraulic performance in the planned ion exchange column was unknown. Moreover, the recycling process of this spherical resorcinol formaldehyde causes its volume to significantly shrink and swell. To determine the spherical media's hydraulic demand a linearly scaled column was designed and tested. The waste simulant used was prototypic of the wastes' viscosity and density. This paper discusses the hydraulic performance of the media that will be used to assist in the design of a full-scale unit

  11. Multiple Rib Exostoses in a Boy: A Rare CaseResulting in Surgery Secondary to Cosmetic Concerns

    Directory of Open Access Journals (Sweden)

    Seyed Hosein Fattahi Masoum

    2014-09-01

    Full Text Available A seven year-old boy with several painless masses on the ribs and shoulder was referred to our hospital. The masses were so prominent that they prevented the child’s sleep. Since the patient had been ridiculed by his friends due to the rib prominences, he had refused to attend school. After clinical and radiological evaluations, the masses were diagnosed as hereditary multiple exostoses of the shoulder and ribs. He underwent surgery for cosmetic reasons resulting in the patient’s return to a normal life.

  12. Stem diameter and height of chrysanthemum cv Yoko ono as ...

    African Journals Online (AJOL)

    Administrator

    2011-09-26

    Sep 26, 2011 ... Booij R (1989). Effect of growth regulators on curd diameter of cauliflower. Sci. Hortic. 38: 23-32. Castro PRC (1998). Use of plant growth regulators in fruit production of vegetable crops and ornamental plants. Série produtor Rural, Ed. especial, Piracicaba: ESALQ- Divisão de Biblioteca e Documentação.

  13. Snapping scapular syndrome secondary to rib intramedullary fixation device

    Directory of Open Access Journals (Sweden)

    Ezequiel E. Zaidenberg

    2015-01-01

    Conclusion: Surgeons should pay attention to any protrusion of intramedullary rib implants, especially in the evaluation of routine X-rays following surgical treatment. We should be aware of the possibility of this rare cause of snapping scapula syndrome to avoid delayed diagnosis and consider removing the implant will resolve the pain.

  14. Application of Displacement Height and Surface Roughness Length to Determination Boundary Layer Development Length over Stepped Spillway

    Directory of Open Access Journals (Sweden)

    Xiangju Cheng

    2014-12-01

    Full Text Available One of the most uncertain parameters in stepped spillway design is the length (from the crest of boundary layer development. The normal velocity profiles responding to the steps as bed roughness are investigated in the developing non-aerated flow region. A detailed analysis of the logarithmic vertical velocity profiles on stepped spillways is conducted through experimental data to verify the computational code and numerical experiments to expand the data available. To determine development length, the hydraulic roughness and displacement thickness, along with the shear velocity, are needed. This includes determining displacement height d and surface roughness length z0 and the relationship of d and z0 to the step geometry. The results show that the hydraulic roughness height ks is the primary factor on which d and z0 depend. In different step height, step width, discharge and intake Froude number, the relations d/ks = 0.22–0.27, z0/ks = 0.06–0.1 and d/z0 = 2.2–4 result in a good estimate. Using the computational code and numerical experiments, air inception will occur over stepped spillway flow as long as the Bauer-defined boundary layer thickness is between 0.72 and 0.79.

  15. Prevalence of Abuse Among Young Children with Rib Fractures: A Systematic Review

    Science.gov (United States)

    Paine, Christine Weirich; Fakeye, Oludolapo; Christian, Cindy W.; Wood, Joanne N.

    2016-01-01

    Objectives We aimed to estimate the prevalence of abuse in young children presenting with rib fractures and to identify demographic, injury, and presentation-related characteristics that affect the probability that rib fractures are secondary to abuse. Methods We searched PubMed/MEDLINE and CINAHL databases for articles published in English between January 1, 1990 and June 30, 2014 on rib fracture etiology in children ≤ 5 years old. Two reviewers independently extracted predefined data elements and assigned quality ratings to included studies. Study-specific abuse prevalences and the sensitivities, specificities, and positive and negative likelihood ratios of patients’ demographic and clinical characteristics for abuse were calculated with 95% confidence intervals. Results Data for 1,396 children ≤ 48 months old with rib fractures were abstracted from 10 articles. Among infants Rib fracture location was not associated with likelihood of abuse. The retrospective design of the included studies and variations in ascertainment of cases, inclusion/exclusion criteria, and child abuse assessments prevented further meta-analysis. Conclusions Abuse is the most common cause of rib fractures in infants rib fractures and characteristics associated with abusive rib fractures. PMID:27749806

  16. Biomechanical rationale and evaluation of an implant system for rib fracture fixation

    OpenAIRE

    Bottlang, M.; Walleser, S.; Noll, M.; Honold, S.; Madey, S. M.; Fitzpatrick, D.; Long, W. B.

    2010-01-01

    Background Biomechanical research directed at developing customized implant solutions for rib fracture fixation is essential to reduce the complexity and to increase the reliability of rib osteosynthesis. Without a simple and reliable implant solution, surgical stabilization of rib fractures will remain underutilized despite proven benefits for select indications. This article summarizes the research, development, and testing of a specialized and comprehensive implant solution for rib fractur...

  17. Thoracic Outlet Syndrome in a Volleyball Player Due to Nonunion of the First Rib Fracture.

    Science.gov (United States)

    Puttmann, Kathleen T; Satiani, Bhagwan; Vaccaro, Patrick

    2016-11-01

    Fracture of the first rib with ensuing callus formation is a rare cause of thoracic outlet syndrome. We report a case of a 17-year-old female volleyball player who presented with months of chronic arm pain. Radiographic imaging demonstrated nonunion fracture of the first rib. Physical therapy had been unsuccessful in relieving the pain, and surgical management was performed with resection of the first rib through a transaxillary approach with complete resolution of symptoms. Inflammation surrounding such fractures may destroy tissue planes, making dissection more technically difficult.

  18. Particles of bottom and suspended sediments: height of rise

    Directory of Open Access Journals (Sweden)

    Khodzinskaya Anna Gennadievna

    2014-12-01

    Full Text Available In the article, characteristic values of dynamic sizes of bottom and suspended sediments, including their probabilistic assessment, are considered. The article presents the processing results in respect of the experimental data for bottom and suspended sediments, obtained in the laboratory environment using samples and filming methods. The experiments have proven that the dynamic hydraulic size determines the height of rise for the particles of the saltation load, rather than suspended ones. In the laboratory environment, the maximal height of rise is mainly driven by the relative flow depth. According to the assessment made by the co-authors, depths of flows employed in the experiments designated for the identification of heights of rises, were comparable to saltation heights of particles. Besides, the saltation height of particles, having relative density well below 2.65, nearly always exceeded half of the depth of the laboratory flow. Hydrodynamic conditions favourable for the separation and motion of artificial particles in coarse surface tanks are far different from the motion of sand particles on the bottom of lowland rivers. Values of hydraulic resistance ratios typical for laboratory experiments by far exceed their values typical for lowland rivers, and it means that the conditions of the experiments performed in the laboratory were similar to those typical for mountain rivers. The research findings have proven that the particle separation and motion pattern, if artificial particles are made of the materials demonstrating variable density and elasticity values and if loose particles travel over fixed ones, is different from the pattern typical for natural particles having variable coarseness.

  19. Chondroblastoma of rib in situs inversus

    Directory of Open Access Journals (Sweden)

    Purwa R Patil

    2014-01-01

    Full Text Available Chondroblastoma is a rare benign cartilaginous tumour accounting for approximately 1% of all bone tumours. It commonly arises from epiphysis of a long bone, particularly the humerus, tibia and femur. Rib is an extremely rare site for this tumour with a few cases reported in the literature. It is commonly seen in children and adults between the ages of 10 - 20 years. Although roentgenographic findings are quite common characteristic of this tumour, it can sometimes be misdiagnosed as giant cell tumour, osteogenic sarcoma and myeloma on histopathology. We report a 26-year-old male patient with situs inversus and chondroblastoma of rib. To the best of our knowledge, this is the first case of chondroblastoma of the rib in a patient of situs inversus. Segmental resection is the treatment of choice. It usually behaves in a benign fashion, but few cases have shown local recurrences and distant metastasis; hence, follow-up of the patient is essential.

  20. Differentiating the Causes of Spontaneous Rib Fracture After Breast Cancer.

    Science.gov (United States)

    Harris, Susan R

    2016-12-01

    Spontaneous rib fracture after treatment for primary breast cancer is not uncommon. Although metastatic disease accounts for about 30% of spontaneous rib fractures and should constitute the first line of diagnostic investigation, other possible contributors include primary osteoporosis or secondary osteoporosis resulting from cancer treatments. Chemotherapy-induced menopause, aromatase inhibitors, radiation therapy, and long-term bisphosphonate use can all contribute to bone fragility, including spontaneous rib fractures in the latter 3. Drawing on recent breast cancer practice guidelines as well as population-based studies of fracture risk for women with a history of breast cancer and systematic reviews, this Perspective will provide an update on recent developments in understanding how to differentiate the possible reasons for non-traumatic rib fracture in women treated for breast cancer. In addition to describing the various possible causes of spontaneous rib fracture, the recommended medical and imaging procedures for differentiating among the potential causes will be presented. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Effect of Tube Diameter on Heat Transfer to Vertically Upward Flowing Supercritical CO{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Deog Ji; Kim, Sin [Cheju National University, Jeju (Korea, Republic of); Bae, Yoon Yeong; Kim, Hwan Yeol; Kim, Hyung Rae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2007-07-01

    Heat transfer characteristics of supercritical carbon dioxide are being investigated experimentally in the test loop named as SPHINX(Supercritical Pressure Heat Transfer Investigation for NeXt generation) at KAERI. The main purpose of the experiment is to provide a reliable heat transfer database for a SCWR (SuperCritical Water-cooled Reactor) by a prudent extension of the carbon dioxide test results to the estimation of a heat transfer for water. The produced data will be used in the thermo-hydraulic design of core and safety analysis for SCWR. The aim of the present paper is to study the influence of a tube diameter on a heat transfer. The experiments were completed for tubes of an inside diameter of 4.4mm and 9.0mm, respectively. The heat transfer characteristics from the two tubes of different diameters were compared and discussed.

  2. Demineralized water flow cancelling experiments with ice plug into high diameter horizontal tube (300 nominal diameter)

    International Nuclear Information System (INIS)

    Gyongyosi, T.; Valeca, S.; Corbescu, B.; Puiu, D.; Panaitescu, V. N.

    2015-01-01

    The isolation with ice plug of a high diameter horizontal pipeline section is a specific technique for repairs activities/ replacements of components owning to thermo-hydraulic installations working with liquid agents. The application of such technique don.t assumes stopping of the entire system. The ice plugging inside of the pipeline assumes using of a special device and of an own specific technology for application. The paper contains a brief description of the experimental technological facilities used, followed by setting off the main moments in evolution of two experimental tests carried out on the test section with 300 mm nominal diameter for demineralized water and, finally, by a brief results analysis and some conclusions. The paper is dedicated to the specialists working in the research and technological engineering. (authors)

  3. Operative Fixation of Rib Fractures Indications, Techniques, and Outcomes.

    Science.gov (United States)

    Galos, David; Taylor, Benjamin; McLaurin, Toni

    2017-01-01

    Rib fractures are extremely common injuries and vary in there severity from single nondisplaced fractures to multiple segmental fractures resulting in flail chest and respiratory compromise. Historically, rib fractures have been treated conservatively with pain control and respiratory therapy. However this method may not be the best treatment modality in all situations. Operative fixation of select rib fractures has been increasing in popularity especially in patients with flail chest and respiratory compromise. Newer techniques use muscle sparing approaches and precontoured locking plate technology to obtain stable fixation and allow improved respiration. Current reports shows that rib fracture fixation offers the benefits of improved respiratory mechanics and improved pain control in the severe chest wall injury with resultant improvement in patient outcomes by decreasing time on the ventilator, time in the intensive care unit, and overall hospital length of stay.

  4. High intensity focused ultrasound (HIFU) therapy for local treatment of hepatocellular carcinoma: Role of partial rib resection

    International Nuclear Information System (INIS)

    Zhu Hui; Zhou Kun; Zhang Lian; Jin Chengbin; Peng Song; Yang Wei; Li Kequan; Su Haibing; Chen Wenzhi; Bai Jin; Wu Feng; Wang, Zhibiao

    2009-01-01

    Objective: It has long been known that high intensity focused ultrasound (HIFU) can kill tissue through coagulative necrosis. However, it is only in recent years that practical clinical applications are becoming possible. Since the ribs have strong reflections to ultrasonic beams, they may affect the deposition of ultrasound energy, decreasing the efficacy of HIFU treatment and increasing the chance of adverse events when the intra-abdominal tumours concealed by ribs are treated. The aim of this study was to evaluate the influence of partial rib resection on the efficacy and safety of HIFU treatment. Methods: This prospective study was approved by the ethics committee at Chongqing University of Medical Sciences. An informed consent form was obtained from each patient and family member. A total of 16 patients with hepatocellular carcinoma (HCC), consisting of 13 males and 3 females, were studied. All patients had the successful HIFU treatment. To create a better acoustic pathway for HIFU treatment, all of the 16 patients had the ribs that shield the tumour mass to be removed. Magnetic resonance imaging (MRI) was used to evaluate the efficacy of HIFU treatment. Results: Sixteen cases had 23 nodules, including 12 cases with a single nodule, 1 case with 2 nodules, 3 cases with 3 nodules. The mean diameter of tumours was 7.0 ± 2.1 cm (5-10 cm). According to TNM classification, 9 patients were diagnosed as stage II, 4 patients were stage III, and 3 patients were stage IV. Follow-up imaging showed an absence of tumour blood supply and shrinkage of all treated lesions. The survival rates at 1, 2, 3, 4, and 5 years were 100%, 83.3%, 69.4%, 55.6%, and 55.6%, respectively. No serious complications were observed in the patients treated with HIFU. Conclusion: Partial rib resection can create a better acoustic pathway of HIFU therapy. Even though it is an invasive treatment, this measure offers patients an improved prospect of complete tumour ablation when no other treatment is

  5. Radiological, computertomographic, pathoanatomical and histological examination of the rib cartilage of the dog

    International Nuclear Information System (INIS)

    Lorber, B.

    2000-06-01

    This study was concerned with the representation and description of the rib cartilage of the dog and the abnormalities of such by means of radiological, computer tomographic, pathoanatomical and histological examinations and the comparison of the results of the various examination methods. The study material consisted of 100 ventral thorax walls of dogs of different ages and breeds. In 39 of the subjects, no abnormalities of rib cartilage other than unremarkable calcification were observed. Among the subjects, there were 11 puppies (0-3 months), whose rib cartilage appeared soft tissue dense due to the absence of calcification, 14 juvenile animals (4-18 months), the rib cartilage of which showed a typical finely granulated structure, and 14 adult dogs (over 18 months), whose rib cartilage exhibited a homogeneous to net-like calcified appearance. In the calcified rib cartilage, the histological section showed a centrally located spongiosa rod surrounded by a hyaline cartilage shell. The calcification tendency of the first pair of rib cartilage was remarkable: in 70 dogs, the first pair of rib cartilage remained uncalcified despite calcification of the other rib cartilage. Sixty-one dogs exhibited rib cartilage abnormalities. According to the radiological appearance of the abnormalities, they were divided into groups and their incidence was calculated. Abnormalities seen included interruption in the continuity of the calcified rib cartilage with and without callus formation, enlargement of rib cartilage, cuff formation, and abnormalities on the Articulationes sternocostales (projections in or around articulations, calcified and fractured joint surfaces). In addition, remarkable calcification patterns were observed. By means of CT examination the densities of the tissue forming the various abnormalities was determined. In the course of the pathoanatomical examination, it was shown that the interruptions in continuity with callus and the various enlarged areas of the

  6. First Rib Fracture Resulting in Horner's Syndrome.

    Science.gov (United States)

    Lin, You-Cheng; Chuang, Ming-Tsung; Hsu, Chin-Hao; Tailor, Al-Rahim Abbasali; Lee, Jung-Shun

    2015-12-01

    First rib fractures and traumatic Horner's syndrome are both quite rare, which can make it difficult to properly diagnose the combination of these 2 conditions in the emergency department. These conditions may be associated with severe medical emergencies, such as ongoing carotid dissection. We present the case of a 33-year-old man who sustained fractures to his right second, third, and fourth ribs and a delay in the diagnosis of left Horner's syndrome after he was involved in a traffic accident. Left Horner's syndrome was caused by a left transverse fracture of the first rib. This fracture was not detected on chest radiographs and required a 3-dimensional reconstructed neck computed tomography scan for detection. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: In the diagnosis of carotid artery dissection, conventional angiography is the criterion standard but is considered invasive. CTA is less invasive, time-saving, and can show more anatomic structures in the neck in addition to the carotid arteries. It is a good screening diagnostic modality in the traumatology department. Although the treatments for Horner's syndrome and first rib fracture are conservative, the early diagnosis of both conditions can resolve the anxiety and uncertainty experienced by both doctors and patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Palaeo-adaptive properties of the xylem of Metasequoia: mechanical/hydraulic compromises.

    Science.gov (United States)

    Jagels, Richard; Visscher, George E; Lucas, John; Goodell, Barry

    2003-07-01

    The xylem of Metasequoia glyptostroboides Hu et Cheng is characterized by very low density (average specific gravity = 0.27) and tracheids with relatively large dimensions (length and diameter). The microfibril angle in the S2 layer of tracheid walls is large, even in outer rings, suggesting a cambial response to compressive rather than tensile stresses. In some cases, this compressive stress is converted to irreversible strain (plastic deformation), as evidenced by cell wall corrugations. The heartwood is moderately decay resistant, helping to prevent Brazier buckling. These xylem properties are referenced to the measured bending properties of modulus of rupture and modulus of elasticity, and compared with other low-to-moderate density conifers. The design strategy for Metasequoia is to produce a mechanically weak but hydraulically efficient xylem that permits rapid height growth and crown development to capture and dominate a wet site environment. The adaptability of these features to a high-latitude Eocene palaeoenvironment is discussed.

  8. Palaeo‐adaptive Properties of the Xylem of Metasequoia: Mechanical/Hydraulic Compromises

    Science.gov (United States)

    JAGELS, RICHARD; VISSCHER, GEORGE E.; LUCAS, JOHN; GOODELL, BARRY

    2003-01-01

    The xylem of Metasequoia glyptostroboides Hu et Cheng is characterized by very low density (average specific gravity = 0·27) and tracheids with relatively large dimensions (length and diameter). The microfibril angle in the S2 layer of tracheid walls is large, even in outer rings, suggesting a cambial response to compressive rather than tensile stresses. In some cases, this compressive stress is converted to irreversible strain (plastic deformation), as evidenced by cell wall corrugations. The heartwood is moderately decay resistant, helping to prevent Brazier buckling. These xylem properties are referenced to the measured bending properties of modulus of rupture and modulus of elasticity, and compared with other low‐to‐moderate density conifers. The design strategy for Metasequoia is to produce a mechanically weak but hydraulically efficient xylem that permits rapid height growth and crown development to capture and dominate a wet site environment. The adaptability of these features to a high‐latitude Eocene palaeoenvironment is discussed. PMID:12763758

  9. Rib forming tool for tubing

    Science.gov (United States)

    Rowley, James P.; Lewandowski, Edward F.; Groh, Edward F.

    1976-01-01

    Three cylindrical rollers are rotatably mounted equidistant from the center of a hollow tool head on radii spaced 120.degree. apart. Each roller has a thin flange; the three flanges lie in a single plane to form an internal circumferential rib in a rotating tubular workpiece. The tool head has two complementary parts with two rollers in one part of the head and one roller in the other part; the two parts are joined by a hinge. A second hinge, located so the rollers are between the two hinges, connects one of the parts to a tool bar mounted in a lathe tool holder. The axes of rotation of both hinges and all three rollers are parallel. A hole exposing equal portions of the three roller flanges is located in the center of the tool head. The two hinges permit the tool head to be opened and rotated slightly downward, taking the roller flanges out of the path of the workpiece which is supported on both ends and rotated by the lathe. The parts of the tool head are then closed on the workpiece so that the flanges are applied to the workpiece and form the rib. The tool is then relocated for forming of the next rib.

  10. Use of a 90° drill and screwdriver for rib fracture stabilization.

    Science.gov (United States)

    Nickerson, Terry P; Kim, Brian D; Zielinski, Martin D; Jenkins, Donald; Schiller, Henry J

    2015-03-01

    Rib fracture stabilization has become a more accepted practice although stabilization of the most cephalad ribs presents a unique challenge. We present our experience with use of a 90° drill and screwdriver to bridge these difficult rib fractures. This retrospective review included patients who underwent rib fracture stabilization from August 1, 2009, through September 30, 2012. Patients were divided into two groups: those whose procedure used the 90° device and those that did not. Data were compared using standard statistical analysis and reported as percentages and medians [interquartile ranges]. P values rib stabilized was different between the 2 groups (3 [2-5] vs. 5 [2-9]; P = 0.001), with more third rib stabilizations in the 90° group (38 vs. 20%; P = 0.04) as well as more total number of ribs fixed (5 vs. 4; P = 0.001). There was no difference in operative time between the 2 groups. The surgical reach for rib fracture stabilization has been extended with use of a 90° drill and screwdriver. High fractures under the scapula where access is technically challenging can be stabilized without prolonging operative times.

  11. Prevalence and characteristics of rib fractures in ex-preterm infants.

    Science.gov (United States)

    Lucas-Herald, Angela; Butler, Sandra; Mactier, Helen; McDevitt, Helen; Young, David; Ahmed, Syed Faisal

    2012-12-01

    This study aimed to identify the prevalence and characteristics of rib fractures in ex-preterm infants. Infants born at rib fractures, and the case notes of all affected individuals were scrutinized. Of the 3318 eligible preterm infants, 1446 had a total of 9386 chest radiographs. Of these infants, 26 (1.8%) were identified as having a total of 62 rib fractures. Their median (range) gestation at birth was 26 weeks (23-34). The median chronological age of these infants at the time of the radiograph was 14 weeks (5 weeks to 8 months). The median corrected gestational age at the time of the radiograph was 39 weeks (34 weeks to 4 months). Of the 62 fractures, 27 (36%) were sited posteriorly, and 15 (53%) of the infants with posterior rib fractures were diagnosed with osteopathy of prematurity. Classic risk including conjugated hyperbilirubinemia and diuretics, were present in 23 of 26 (88%) infants. A full skeletal survey was performed in 8 of 26 (31%). Investigations for nonaccidental injury occurred in 4 of 26 (15%) cases. Evidence of rib fractures is present in ~2% of ex-preterm infants. The evaluation of these fractures in infancy requires a detailed neonatal history irrespective of the site of rib fracture.

  12. [Rib cage ostheosynthesis. Literature review and case reports].

    Science.gov (United States)

    Jiménez-Quijano, Andrés; Varón-Cotés, Juan Carlos; García-Herreros-Hellal, Luis Gerardo; Espinosa-Moya, Beatriz; Rivero-Rapalino, Oscar; Salazar-Marulanda, Michelle

    2015-01-01

    Fractures of the chest wall include sternum and rib fractures. Traditionally they are managed conservatively due to the anatomy of the rib cage that allows most of them to remain stable and to form a callus that unites the fractured segments. In spite of this management, some patients present with chronic pain or instability of the wall which makes them require some type of fixation. The present article performs a literature review based on 4 cases. The first case was a 61 year-old man with blunt chest trauma, with a great deformity of the chest wall associated with subcutaneous emphysema, and pneumothorax. The second case was a 51 year-old man with blunt chest trauma, initially managed at another institution, who despite treatment, had persistent pain and dyspnoea. The third case was a 30 year-old man that suffered a motor vehicle accident, with resulting pain and crepitation of the rib cage and with diagnostic images showing multiple rib fractures. The last case is a 62 year-old man that fell down the stairs, with blunt chest trauma with high intensity pain, dyspnoea and basal ipsilateral hypoventilation. Rib fracture fixation offers a good alternative in selected patients to decrease associated morbidity, leading to a patient's fast return to his or her working life. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  13. Emerging from the rib: resolving the turtle controversies.

    Science.gov (United States)

    Rice, Ritva; Riccio, Paul; Gilbert, Scott F; Cebra-Thomas, Judith

    2015-05-01

    Two of the major controversies in the present study of turtle shell development involve the mechanism by which the carapacial ridge initiates shell formation and the mechanism by which each rib forms the costal bones adjacent to it. This paper claims that both sides of each debate might be correct-but within the species examined. Mechanism is more properly "mechanisms," and there is more than one single way to initiate carapace formation and to form the costal bones. In the initiation of the shell, the rib precursors may be kept dorsal by either "axial displacement" (in the hard-shell turtles) or "axial arrest" (in the soft-shell turtle Pelodiscus), or by a combination of these. The former process would deflect the rib into the dorsal dermis and allow it to continue its growth there, while the latter process would truncate rib growth. In both instances, though, the result is to keep the ribs from extending into the ventral body wall. Our recent work has shown that the properties of the carapacial ridge, a key evolutionary innovation of turtles, differ greatly between these two groups. Similarly, the mechanism of costal bone formation may differ between soft-shell and hard-shell turtles, in that the hard-shell species may have both periosteal flattening as well as dermal bone induction, while the soft-shelled turtles may have only the first of these processes. © 2015 Wiley Periodicals, Inc.

  14. Memory for target height is scaled to observer height.

    Science.gov (United States)

    Twedt, Elyssa; Crawford, L Elizabeth; Proffitt, Dennis R

    2012-04-01

    According to the embodied approach to visual perception, individuals scale the environment to their bodies. This approach highlights the central role of the body for immediate, situated action. The present experiments addressed whether body scaling--specifically, eye-height scaling--occurs in memory when action is not immediate. Participants viewed standard targets that were either the same height as, taller than, or shorter than themselves. Participants then viewed a comparison target and judged whether the comparison was taller or shorter than the standard target. Participants were most accurate when the standard target height matched their own heights, taking into account postural changes. Participants were biased to underestimate standard target height, in general, and to push standard target height away from their own heights. These results are consistent with the literature on eye-height scaling in visual perception and suggest that body scaling is not only a useful metric for perception and action, but is also preserved in memory.

  15. Flank pseudohernia following posterior rib fracture: a case report.

    Science.gov (United States)

    Butensky, Adam M; Gruss, Leah P; Gleit, Zachary L

    2016-10-01

    A pseudohernia is an abdominal wall bulge that may be mistaken for a hernia but that lacks the disruption of the abdominal wall that characterizes a hernia. Thus, the natural history and treatment of this condition differ from those of a hernia. This is the first report of a pseudohernia due to cough-associated rib fracture. A case of pseudohernia due to fractures of the 10 th and 11 th ribs in a 68-year-old white woman is presented. The patient suffered from a major coughing episode 1 year prior to her presentation, after which she noted a progressively enlarging bulge in her left flank. Computed tomography demonstrated a bulge in the abdominal wall containing bowel and spleen but with all muscle and fascial layers intact; in addition, lateral 10 th rib and posterior 11 th rib fractures were noted. As there was no defect in muscle or fascia, we diagnosed a pseudohernia, likely due to a denervation injury from the fractured ribs. Symptomatic treatment was recommended, including wearing a corset and referral to a pain management clinic. Symptomatic treatment is thought to be the mainstay of therapy for pseudohernias, as surgical intervention is unlikely to be of benefit.

  16. The Influence of Waist Thickness of Dolosse on the Hydraulic Stability of Dolosse Armour

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; Brejnegaard-Nielsen, Torben

    1987-01-01

    stability was studied. A low packing density of approximately 0.65 was used corresponding to a two-layer armour with high porosity. From the results it is concluded that the hydraulic stability of Dolos armour is not very sensitive to variations in the waist to height ratio. Only for damage levels exceeding...... displacement of approximately 5% of the armour blocks in the most exposed area there seems to be a significant decrease in hydraulic stability with increasing waist to height ratio. Thus the waist ratio only influences the residual hydraulic stability. Based on a short discussion of stressed in armour units...... underlines the need for adoption of more restrictive safety factors than generally used in rubble mound breakwater design. It also supports the idea of a probabilistic approach in the design process....

  17. Optimization of Multiple Seepage Piping Parameters to Maximize the Critical Hydraulic Gradient in Bimsoils

    Directory of Open Access Journals (Sweden)

    Yu Wang

    2017-10-01

    Full Text Available Seepage failure in the form of piping can strongly influence the stability of block-in-matrix-soils (bimsoils, as well as weaken and affect the performance of bimsoil structures. The multiple-factor evaluation and optimization play a crucial role in controlling the seepage failure in bimsoil. The aim of this study is to improve the ability to control the piping seepage failure in bimsoil. In this work, the response surface method (RSM was employed to evaluate and optimize the multiple piping parameters to maximize the critical hydraulic gradient (CHG, in combination with experimental modeling based on a self-developed servo-controlled flow-erosion-stress coupled testing system. All of the studied specimens with rock block percentage (RBP of 30%, 50%, and 70% were produced as a cylindrical shape (50 mm diameter and 100 mm height by compaction tests. Four uncertain parameters, such as RBP, soil matrix density, confining pressure, and block morphology were used to fit an optimal response of the CHG. The sensitivity analysis reveals the influential order of the studied factors to CHG. It is found that RBP is the most sensitive factor, the CHG decreases with the increase of RBP, and CHG increases with the increase of confining pressure, soil matrix density, and block angularity.

  18. Acute rib fracture diagnosis in an infant by US: a matter of child protection

    International Nuclear Information System (INIS)

    Kelloff, Jennifer; Spivey, Maria; Hulett, Rebecca

    2009-01-01

    Rib fractures in infants and children are highly specific for inflicted injury in the absence of a major accidental injury or underlying bone disorder. We present a 9-week-old infant diagnosed with an acute rib fracture by US at the site where physicians palpated chest wall crepitus when no rib fractures had been visualized on the skeletal survey, including oblique views of the ribs. Based on the US diagnosis of the acute rib fracture the infant was taken into protective custody. Follow-up skeletal survey 2 weeks later revealed healing fractures of the left 6th and 7th posterolateral ribs and right 7th, 8th and 9th anterolateral ribs. We were unable to locate previous reports describing the diagnosis of rib fractures in infants by US. (orig.)

  19. Acute rib fracture diagnosis in an infant by US: a matter of child protection

    Energy Technology Data Exchange (ETDEWEB)

    Kelloff, Jennifer; Spivey, Maria [Washington University School of Medicine, Department of Pediatrics, Section on Child Abuse and Neglect, St. Louis Children' s Hospital, One Children' s Place, Box 8116, St. Louis, MO (United States); Hulett, Rebecca [Washington University School of Medicine, Department of Radiology, St. Louis Children' s Hospital, St. Louis, MO (United States)

    2009-01-15

    Rib fractures in infants and children are highly specific for inflicted injury in the absence of a major accidental injury or underlying bone disorder. We present a 9-week-old infant diagnosed with an acute rib fracture by US at the site where physicians palpated chest wall crepitus when no rib fractures had been visualized on the skeletal survey, including oblique views of the ribs. Based on the US diagnosis of the acute rib fracture the infant was taken into protective custody. Follow-up skeletal survey 2 weeks later revealed healing fractures of the left 6th and 7th posterolateral ribs and right 7th, 8th and 9th anterolateral ribs. We were unable to locate previous reports describing the diagnosis of rib fractures in infants by US. (orig.)

  20. Analysis of the nature of injuries in victims of fall from height

    Directory of Open Access Journals (Sweden)

    Magdalena E. Kusior

    2017-01-01

    Full Text Available Aim of study: To assess the types and extent of injuries sustained by victims of fall from height depending on the height of fall. Material and methods: The study included 338 bodies of victims of fatal falls from different heights (from the 1st to 10th floors who were subjected to medico-legal autopsy at the Department of Forensic Medicine, Jagiellonian University Medical College, between 1995 and 2014. For each individual, selected data were collected including gender, age, body height, injury types and presence of alcohol or other intoxicants in blood. The analysis comprised injuries to the brain, thoracic and abdominal organs, fractures of the skull, extremities, ribs and spine, and fractures of the scapula, clavicle and sternum (considered together. The study focused on determining the frequency of occurrence of different injuries in relation to one another and depending on the height of fall. Results : The number and extent of injuries was found to increase along with the height of fall. Three injury types, including injuries to the mesentery and both kidneys and fractures of upper extremity small bones, were shown to occur from the threshold heights of the 3rd, 4th and 6th floors. Eleven injuries demonstrated a statistically significant correlation with the height of fall. The study also revealed a number of correlations between the frequencies of occurrence of different injuries. Conclusions : Injuries found from the threshold value may suggest the minimal height of fall. The presence of injuries which correlate with increasing height, and the overall number of injuries observed in victims of fall from height, may be useful for inferring the height of the fall.

  1. Tree height–diameter allometry across the United States

    Science.gov (United States)

    Hulshof, Catherine M; Swenson, Nathan G; Weiser, Michael D

    2015-01-01

    The relationship between tree height and diameter is fundamental in determining community and ecosystem structure as well as estimates of biomass and carbon storage. Yet our understanding of how tree allometry relates to climate and whole organismal function is limited. We used the Forest Inventory and Analysis National Program database to determine height–diameter allometries of 2,976,937 individuals of 293 tree species across the United States. The shape of the allometric relationship was determined by comparing linear and nonlinear functional forms. Mixed-effects models were used to test for allometric differences due to climate and floristic (between angiosperms and gymnosperms) and functional groups (leaf habit and shade tolerance). Tree allometry significantly differed across the United States largely because of climate. Temperature, and to some extent precipitation, in part explained tree allometric variation. The magnitude of allometric variation due to climate, however, had a phylogenetic signal. Specifically, angiosperm allometry was more sensitive to differences in temperature compared to gymnosperms. Most notably, angiosperm height was more negatively influenced by increasing temperature variability, whereas gymnosperm height was negatively influenced by decreasing precipitation and increasing altitude. There was little evidence to suggest that shade tolerance influenced tree allometry except for very shade-intolerant trees which were taller for any given diameter. Tree allometry is plastic rather than fixed and scaling parameters vary around predicted central tendencies. This allometric variation provides insight into life-history strategies, phylogenetic history, and environmental limitations at biogeographical scales. PMID:25859325

  2. Urban tree species show the same hydraulic response to vapor pressure deficit across varying tree size and environmental conditions.

    Directory of Open Access Journals (Sweden)

    Lixin Chen

    Full Text Available The functional convergence of tree transpiration has rarely been tested for tree species growing under urban conditions even though it is of significance to elucidate the relationship between functional convergence and species differences of urban trees for establishing sustainable urban forests in the context of forest water relations.We measured sap flux of four urban tree species including Cedrus deodara, Zelkova schneideriana, Euonymus bungeanus and Metasequoia glyptostroboides in an urban park by using thermal dissipation probes (TDP. The concurrent microclimate conditions and soil moisture content were also measured. Our objectives were to examine 1 the influence of tree species and size on transpiration, and 2 the hydraulic control of urban trees under different environmental conditions over the transpiration in response to VPD as represented by canopy conductance. The results showed that the functional convergence between tree diameter at breast height (DBH and tree canopy transpiration amount (E(c was not reliable to predict stand transpiration and there were species differences within same DBH class. Species differed in transpiration patterns to seasonal weather progression and soil water stress as a result of varied sensitivity to water availability. Species differences were also found in their potential maximum transpiration rate and reaction to light. However, a same theoretical hydraulic relationship between G(c at VPD = 1 kPa (G(cref and the G(c sensitivity to VPD (-dG(c/dlnVPD across studied species as well as under contrasting soil water and R(s conditions in the urban area.We concluded that urban trees show the same hydraulic regulation over response to VPD across varying tree size and environmental conditions and thus tree transpiration could be predicted with appropriate assessment of G(cref.

  3. Urban tree species show the same hydraulic response to vapor pressure deficit across varying tree size and environmental conditions.

    Science.gov (United States)

    Chen, Lixin; Zhang, Zhiqiang; Ewers, Brent E

    2012-01-01

    The functional convergence of tree transpiration has rarely been tested for tree species growing under urban conditions even though it is of significance to elucidate the relationship between functional convergence and species differences of urban trees for establishing sustainable urban forests in the context of forest water relations. We measured sap flux of four urban tree species including Cedrus deodara, Zelkova schneideriana, Euonymus bungeanus and Metasequoia glyptostroboides in an urban park by using thermal dissipation probes (TDP). The concurrent microclimate conditions and soil moisture content were also measured. Our objectives were to examine 1) the influence of tree species and size on transpiration, and 2) the hydraulic control of urban trees under different environmental conditions over the transpiration in response to VPD as represented by canopy conductance. The results showed that the functional convergence between tree diameter at breast height (DBH) and tree canopy transpiration amount (E(c)) was not reliable to predict stand transpiration and there were species differences within same DBH class. Species differed in transpiration patterns to seasonal weather progression and soil water stress as a result of varied sensitivity to water availability. Species differences were also found in their potential maximum transpiration rate and reaction to light. However, a same theoretical hydraulic relationship between G(c) at VPD = 1 kPa (G(cref)) and the G(c) sensitivity to VPD (-dG(c)/dlnVPD) across studied species as well as under contrasting soil water and R(s) conditions in the urban area. We concluded that urban trees show the same hydraulic regulation over response to VPD across varying tree size and environmental conditions and thus tree transpiration could be predicted with appropriate assessment of G(cref).

  4. Low evaluation rate for osteoporosis among patients presenting with a rib fracture.

    Science.gov (United States)

    Kim, Whang; Gong, Hyun Sik; Lee, Seung Hoo; Park, Jin Woo; Kim, Kahyun; Baek, Goo Hyun

    2017-12-01

    This study in a regional hospital setting found a low evaluation rate for osteoporosis among patients presenting with a rib fracture. Increased emphasis or education for osteoporosis evaluation may be necessary in case of rib fractures. Rib fractures from a low-energy trauma are common in the elderly, and a history of rib fracture has been reported to increase the risk for a subsequent osteoporotic fracture. The purpose of this study was to evaluate how many of the patients presenting with an isolated rib fracture were being evaluated for osteoporosis and the risk for a subsequent fracture. We retrospectively reviewed all patients aged 50 years or older who were diagnosed with a rib fracture between January 2011 and April 2016 at a regional tertiary care university hospital near Seoul, South Korea. We excluded those who had been treated for osteoporosis or those with other concomitant fractures or fractures from a motor vehicle accident or cancer. We evaluated the frequency of dual energy X-ray absorptiometry (DXA) scan examinations in these patients. There were 231 patients with isolated rib fractures (132 men and 99 women). The mean age was 65 years. Rib fractures were most commonly diagnosed at the emergency department and most of the patients were referred to the department of thoracic surgery for follow-up evaluations. Of these 231 patients, 29 (12%) had DXA examinations after the injury, and only 9 (4%) of them did so within 6 months. Physicians specializing in orthopedic surgery, family medicine, internal medicine, rehabilitation medicine, and emergency medicine were ordering the examination. This study in a regional hospital setting found a low evaluation rate for osteoporosis among patients presenting with a rib fracture. This study suggests that increased emphasis or education for osteoporosis evaluation may be necessary for physicians who are often referred to for care of rib fractures.

  5. The Merkel equation revisited: A novel method to compute the packed height of a cooling tower

    International Nuclear Information System (INIS)

    Picardo, J.R.; Variyar, J.E.

    2012-01-01

    Highlights: ► A relationship between packed height and excess air flow rate is derived. ► The relationship is independent of tower diameter and water flow rate. ► It is well approximated by a power law curve for industrially relevant cases. ► An algorithm to compute the thermodynamic minimum air flow rate is detailed. ► Computation of the packed height is simplified especially for design-optimization. - Abstract: In this work, a new methodology of analysis and computation is presented which simplifies calculation of the packed height in a counter current cooling tower, especially for design and cost optimization studies. An algorithm is presented with an implementation in MATLAB to compute the thermodynamic minimum air flow rate for the desired cooling. Combining the Merkel equation and a standard empirical mass transfer correlation, the packed height is shown to be independent of the water flow rate and tower diameter, and dependent only on the excess air flow. The relationship is unique for a given cooling range of water and inlet air wet bulb temperature. A simple power law regression is used to approximate this relationship and results are presented for Vertical Corrugated Packing.

  6. Investigation of forced convection heat transfer of supercritical pressure water in a vertically upward internally ribbed tube

    International Nuclear Information System (INIS)

    Wang Jianguo; Li Huixiong; Guo Bin; Yu Shuiqing; Zhang Yuqian; Chen Tingkuan

    2009-01-01

    In the present paper, the forced convection heat transfer characteristics of water in a vertically upward internally ribbed tube at supercritical pressures were investigated experimentally. The six-head internally ribbed tube is made of SA-213T12 steel with an outer diameter of 31.8 mm and a wall thickness of 6 mm and the mean inside diameter of the tube is measured to be 17.6 mm. The experimental parameters were as follows. The pressure at the inlet of the test section varied from 25.0 to 29.0 MPa, and the mass flux was from 800 to 1200 kg/(m 2 s), and the inside wall heat flux ranged from 260 to 660 kW/m 2 . According to experimental data, the effects of heat flux and pressure on heat transfer of supercritical pressure water in the vertically upward internally ribbed tube were analyzed, and the characteristics and mechanisms of heat transfer enhancement, and also that of heat transfer deterioration, were also discussed in the so-called large specific heat region. The drastic changes in thermophysical properties near the pseudocritical points, especially the sudden rise in the specific heat of water at supercritical pressures, may result in the occurrence of the heat transfer enhancement, while the covering of the heat transfer surface by fluids lighter and hotter than the bulk fluid makes the heat transfer deteriorated eventually and explains how this lighter fluid layer forms. It was found that the heat transfer characteristics of water at supercritical pressures were greatly different from the single-phase convection heat transfer at subcritical pressures. There are three heat transfer modes of water at supercritical pressures: (1) normal heat transfer, (2) deteriorated heat transfer with low HTC but high wall temperatures in comparison to the normal heat transfer, and (3) enhanced heat transfer with high HTC and low wall temperatures in comparison to the normal heat transfer. It was also found that the heat transfer deterioration at supercritical pressures was

  7. Prolonged pain and disability are common after rib fractures.

    Science.gov (United States)

    Fabricant, Loic; Ham, Bruce; Mullins, Richard; Mayberry, John

    2013-05-01

    The contribution of rib fractures to prolonged pain and disability may be underappreciated and undertreated. Clinicians are traditionally taught that the pain and disability of rib fractures resolves in 6 to 8 weeks. This study was a prospective observation of 203 patients with rib fractures at a level 1 trauma center. Chest wall pain was evaluated by the McGill Pain Questionnaire (MPQ) pain rating index (PRI) and present pain intensity (PPI). Prolonged pain was defined as a PRI of 8 or more at 2 months after injury. Prolonged disability was defined as a decrease in 1 or more levels of work or functional status at 2 months after injury. Predictors of prolonged pain and disability were determined by multivariate analysis. One hundred forty-five male patients and 58 female patients with a mean injury severity score (ISS) of 20 (range, 1 to 59) had a mean of 5.4 rib fractures (range, 1 to 29). Forty-four (22%) patients had bilateral fractures, 15 (7%) had flail chest, and 92 (45%) had associated injury. One hundred eighty-seven patients were followed 2 months or more. One hundred ten (59%) patients had prolonged chest wall pain and 142 (76%) had prolonged disability. Among 111 patients with isolated rib fractures, 67 (64%) had prolonged chest wall pain and 69 (66%) had prolonged disability. MPQ PPI was predictive of prolonged pain (odds ratio [OR], 1.8; 95% confidence interval [CI], 1.4 to 2.5), and prolonged disability (OR, 2.2; 95% CI, 1.5 to 3.4). The presence of significant associated injuries was predictive of prolonged disability (OR, 5.9; 95% CI, 1.4 to 29). Prolonged chest wall pain is common, and the contribution of rib fractures to disability is greater than traditionally expected. Further investigation into more effective therapies that prevent prolonged pain and disability after rib fractures is needed. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Rib fractures under anterior-posterior dynamic loads: experimental and finite-element study.

    Science.gov (United States)

    Li, Zuoping; Kindig, Matthew W; Kerrigan, Jason R; Untaroiu, Costin D; Subit, Damien; Crandall, Jeff R; Kent, Richard W

    2010-01-19

    The purpose of this study was to investigate whether using a finite-element (FE) mesh composed entirely of hexahedral elements to model cortical and trabecular bone (all-hex model) would provide more accurate simulations than those with variable thickness shell elements for cortical bone and hexahedral elements for trabecular bone (hex-shell model) in the modeling human ribs. First, quasi-static non-injurious and dynamic injurious experiments were performed using the second, fourth, and tenth human thoracic ribs to record the structural behavior and fracture tolerance of individual ribs under anterior-posterior bending loads. Then, all-hex and hex-shell FE models for the three ribs were developed using an octree-based and multi-block hex meshing approach, respectively. Material properties of cortical bone were optimized using dynamic experimental data and the hex-shell model of the fourth rib and trabecular bone properties were taken from the literature. Overall, the reaction force-displacement relationship predicted by both all-hex and hex-shell models with nodes in the offset middle-cortical surfaces compared well with those measured experimentally for all the three ribs. With the exception of fracture locations, the predictions from all-hex and offset hex-shell models of the second and fourth ribs agreed better with experimental data than those from the tenth rib models in terms of reaction force at fracture (difference rib responses and bone fractures for the loading conditions considered, but coarse hex-shell models with constant or variable shell thickness were more computationally efficient and therefore preferred. Copyright 2009 Elsevier Ltd. All rights reserved.

  9. Hitungan Diameter Pipa pada Sistem Penyediaan Air Minum sederhana

    Directory of Open Access Journals (Sweden)

    Wahyu Widiyanto

    2010-02-01

    Full Text Available Drinking water sector is one of the public services which is connected tightly to poverty decrease. A small community water supply is more suitable if it uses a simple system which does not need sophisticated planning and construction. Nevertheless, hydraulics calculation should be always conducted accurately because it will influence water supply performance. In this case, pipe hydraulics needs more overview because system reliability depends on pipe capacity. This study discusses two methods of pipe diameter calculation at a simple drinking water supply system. For planning assistance, Directorate General Cipta Karya-Public Work Ministry issued Technical Guideline Book for Simple Drinking Water Construction in 2007. One of its chapters discusses about a method to find pipe diameter based on several tables available, but it is not given an explanation about basic theory of the tables so there is a doubt for planners. For the reason, comparison between the use of the tables (Juknis Method and Darcy-Weisbach Formula to calculate pipe diameter will be discussed. Data from 5 villages in Kebumen Regency will be utilized to support analysis. The result of procedure for making comparison shows that there is no significant difference (less than 4% between the result of calculation by Darcy-Weisbach Formula and Juknis Method with accurate interpolation. Both of the methods can be applied with its advantages and disadvantages. It is suggested that Darcy-Weisbach Formula is always implemented to re-check toward pipe diameter which is available in the market and will be used in the system.

  10. Thoracic epidural steroid injection for rib fracture pain.

    Science.gov (United States)

    Rauchwerger, Jacob J; Candido, Kenneth D; Deer, Timothy R; Frogel, Jonathan K; Iadevaio, Robert; Kirschen, Neil B

    2013-06-01

    Treatment for rib fracture pain can be broadly divided into pharmacologic approaches with oral and/or parenteral medication and interventional approaches utilizing neuraxial analgesia or peripheral nerve blocks to provide pain relief. Both approaches attempt to control nociceptive and neuropathic pain secondary to osseous injury and nerve insult, respectively. Success of treatment is ultimately measured by the ability of the selected modality to decrease pain, chest splinting, and to prevent sequelae of injury, such as pneumonia. Typically, opioids and NSAIDs are the drugs of first choice for acute pain because of ease of administration, immediate onset of action, and rapid titration to effect. In contrast, neuropathic pain medications have a slower onset of action and are more difficult to titrate to therapeutic effect. Interventional approaches include interpleural catheters, intercostal nerve blocks, paravertebral nerve blocks, and thoracic and lumbar epidural catheters. Each intervention has its own inherent advantages, disadvantages, and success rates. Rib fracture pain management practice is founded on the thoracic surgical and anesthesiology literature. Articles addressing rib fracture pain are relatively scarce in the pain medicine literature. As life expectancy increases, and as healthcare system modifications are implemented, pain medicine physicians may be consulted to treat increasing number of patients suffering rib fracture pain and may need to resort to novel therapeutic measures because of financial constraints imposed by those changes. Here we present the first published case series of thoracic epidural steroid injections used for management of rib fracture pain. © 2012 The Authors Pain Practice © 2012 World Institute of Pain.

  11. Improving vertebra segmentation through joint vertebra-rib atlases

    Science.gov (United States)

    Wang, Yinong; Yao, Jianhua; Roth, Holger R.; Burns, Joseph E.; Summers, Ronald M.

    2016-03-01

    Accurate spine segmentation allows for improved identification and quantitative characterization of abnormalities of the vertebra, such as vertebral fractures. However, in existing automated vertebra segmentation methods on computed tomography (CT) images, leakage into nearby bones such as ribs occurs due to the close proximity of these visibly intense structures in a 3D CT volume. To reduce this error, we propose the use of joint vertebra-rib atlases to improve the segmentation of vertebrae via multi-atlas joint label fusion. Segmentation was performed and evaluated on CTs containing 106 thoracic and lumbar vertebrae from 10 pathological and traumatic spine patients on an individual vertebra level basis. Vertebra atlases produced errors where the segmentation leaked into the ribs. The use of joint vertebra-rib atlases produced a statistically significant increase in the Dice coefficient from 92.5 +/- 3.1% to 93.8 +/- 2.1% for the left and right transverse processes and a decrease in the mean and max surface distance from 0.75 +/- 0.60mm and 8.63 +/- 4.44mm to 0.30 +/- 0.27mm and 3.65 +/- 2.87mm, respectively.

  12. Vital capacity helps predict pulmonary complications after rib fractures.

    Science.gov (United States)

    Carver, Thomas W; Milia, David J; Somberg, Chloe; Brasel, Karen; Paul, Jasmeet

    2015-09-01

    Traumatic rib fractures are associated with significant morbidity. Vital capacity (VC) assesses pulmonary function; however, limited data link VC to patient outcomes. Our objective was to determine if VC predicted complications and disposition in patients with rib fractures. This is a retrospective chart review of all patients with fractured ribs admitted to a Level 1 trauma center during a 4-year period. Patients were excluded if no VC was performed within 48 hours of admission. Data collected included demographics, hospital/intensive care unit length of stay, epidural, discharge to home versus extended care facility, mortality, chest Abbreviated Injury Scale (AIS) score, Injury Severity Score (ISS), number of rib fractures, hemothorax/pneumothorax, presence of pulmonary contusion, presence of chest tube, chronic obstructive pulmonary disease, and average daily VC (percentage of predicted). Pulmonary complication was defined as pneumonia, need for intubation, new home O2 requirement, readmission for pulmonary issue, or intensive care unit transfer. Statistical analysis was performed using χ and multivariate logistic regression. Of 801 patients with rib fractures, 683 had VC performed within 48 hours. Average age was 53 years, median ISS was 13 (interquartile range, 9-18), and median length of stay was 5 days. Most (72%) were discharged home, and 26% went to extended care facility. Ten percent developed a pulmonary complication, and there were nine deaths. Every 10% increase in VC was associated with 36% decrease in likelihood of pulmonary complication. Patients with a VC greater than 50% had a significantly lower association of pulmonary complication (p = 0.017), and a VC of less than 30% was independently associated with pulmonary complication (odds ratio, 2.36). Patients with fractured ribs and VC of less than 30% have significant association for pulmonary complication. Higher VC is associated with lower likelihood of pulmonary complication. VC may help

  13. Reports on various anomalies of the ribs

    Energy Technology Data Exchange (ETDEWEB)

    Brinkmann, G.; Brix, F.

    1988-02-01

    Three patients are presented who were suffering from different anomalies of the ribs: There was one each plus and minus variant and a female patient with Gorlin-Goltz syndrome (basal cell nevus syndrome) demonstrating several changes in the ribs as an expression of a genetically determined segmentation disturbance. These presentations are followed by a detailed discussion on the types and causes of such anomalies.

  14. Reports on various anomalies of the ribs

    International Nuclear Information System (INIS)

    Brinkmann, G.; Brix, F.

    1988-01-01

    Three patients are presented who were suffering from different anomalies of the ribs: There was one each plus and minus variant and a female patient with Gorlin-Goltz syndrome (basal cell nevus syndrome) demonstrating several changes in the ribs as an expression of a genetically determined segmentation disturbance. These presentations are followed by a detailed discussion on the types and causes of such anomalies. (orig.) [de

  15. The Efficacy of Platelet-Rich Plasma in the Treatment of Rib Fractures.

    Science.gov (United States)

    Gunay, Samil; Candan, Huseyin; Yılmaz, Rahsan; Eser, Irfan; Aydoğmus, Umit

    2017-10-01

    Background  Rib fracture is the most common result of thoracic traumas. Intrapulmonary shunt, alveolar capillary membrane damage, intra-alveolar hemorrhage, and hypoxia may develop following rib fractures. Therefore, prompt treatment is important. The aim of this experimental study was to analyze the effects of platelet-rich plasma (PRP) on rib fractures to secure a speedier and more efficient treatment method. Materials and Methods  The study involved 18 New Zealand white rabbits, randomly divided into three groups as Group 1, the sham group with no surgical intervention; Group 2, the control group in which simple rib fractures were applied and no treatment; and Group 3, in which rib fractures were applied and then PRP treatment was administered. Results  The mean recovery plate thickness measurements were found to be statistically significantly higher in the PRP group compared with the other groups ( p  rib fractures and used easily in pseudoarthrosis, surgical fracture, or flail chest. Georg Thieme Verlag KG Stuttgart · New York.

  16. The prevalence of cervical ribs in Enugu, Nigeria

    African Journals Online (AJOL)

    2015-11-18

    Nov 18, 2015 ... ... prevalence of cervical ribs and its variation with sex and age among patients ... The patients' identities were removed from the ... syndrome, only 8–10% actually has cervical rib as ... Anatomy, symptoms, diagnosis, and treatment. ... Illinois: American Association of Neurological Surgeons; 1998. p. 157-70.

  17. Subchannel flow analysis in Candu and ACR pressure tubes with radial and axial diameter variation

    Energy Technology Data Exchange (ETDEWEB)

    Catana, A.; Prodea, L. [RAAN, Institute for Nuclear Research, Arges (Romania); Danila, N.; Prisecaru, I.; Dupleac, D. [Bucharest Univ. Politehnica(Romania)

    2007-07-01

    The Candu (Canada Deuterium Uranium) and ACR (Advanced Candu Reactor) are pressure tubes (PT) heavy water moderated reactors. Candu are heavy water and ACR are light water cooled reactors. The pressure tube is filled with 12 bundles, each consisting of 37 respectively 43 fuel rods. One Candu reactor is in operation at Cernavoda, Romania since 1996. ACR is a proposed advanced Candu. PT diameter variation has a significant impact on the thermal-hydraulic parameters. Almost all thermal-hydraulic parameters change, but some of them have a greater significance. In this work we have considered a set of radial and axial PT diameter variations both for Candu-600 and ACR-700 reactors using various types of fuel bundles. We can conclude the following: 1) some thermal-hydraulic parameters are significantly influenced: critical heat flux (CHF), pressure drop, or void fraction; 2) the most significant parameter CHF is worsening which reduces the safety margin; 3) some fuel types present a better thermal-hydraulic behavior; and 4) fuel bundles with fresh fuel or low burnup have a worse thermal-hydraulic behaviour than those at average burn-up.

  18. Subchannel flow analysis in Candu and ACR pressure tubes with radial and axial diameter variation

    International Nuclear Information System (INIS)

    Catana, A.; Prodea, L.; Danila, N.; Prisecaru, I.; Dupleac, D.

    2007-01-01

    The Candu (Canada Deuterium Uranium) and ACR (Advanced Candu Reactor) are pressure tubes (PT) heavy water moderated reactors. Candu are heavy water and ACR are light water cooled reactors. The pressure tube is filled with 12 bundles, each consisting of 37 respectively 43 fuel rods. One Candu reactor is in operation at Cernavoda, Romania since 1996. ACR is a proposed advanced Candu. PT diameter variation has a significant impact on the thermal-hydraulic parameters. Almost all thermal-hydraulic parameters change, but some of them have a greater significance. In this work we have considered a set of radial and axial PT diameter variations both for Candu-600 and ACR-700 reactors using various types of fuel bundles. We can conclude the following: 1) some thermal-hydraulic parameters are significantly influenced: critical heat flux (CHF), pressure drop, or void fraction; 2) the most significant parameter CHF is worsening which reduces the safety margin; 3) some fuel types present a better thermal-hydraulic behavior; and 4) fuel bundles with fresh fuel or low burnup have a worse thermal-hydraulic behaviour than those at average burn-up

  19. Axial vessel widening in arborescent monocots.

    Science.gov (United States)

    Petit, Giai; DeClerck, Fabrice A J; Carrer, Marco; Anfodillo, Tommaso

    2014-02-01

    Dicotyledons have evolved a strategy to compensate for the increase in hydraulic resistance to water transport with height growth by widening xylem conduits downwards. In monocots, the accumulation of hydraulic resistance with height should be similar, but the absence of secondary growth represents a strong limitation for the maintenance of xylem hydraulic efficiency during ontogeny. The hydraulic architecture of monocots has been studied but it is unclear how monocots arrange their axial vascular structure during ontogeny to compensate for increases in height. We measured the vessel lumina and estimated the hydraulic diameter (Dh) at different heights along the stem of two arborescent monocots, Bactris gasipaes (Kunth) and Guadua angustifolia (Kunth). For the former, we also estimated the variation in Dh along the leaf rachis. Hydraulic diameter increased basally from the stem apex to the base with a scaling exponent (b) in the range of those reported for dicot trees (b = 0.22 in B. gasipaes; b = 0.31 and 0.23 in G. angustifolia). In B. gasipaes, vessels decrease in Dh from the stem's centre towards the periphery, an opposite pattern compared with dicot trees. Along the leaf rachis, a pattern of increasing Dh basally was also found (b = 0.13). The hydraulic design of the monocots studied revealed an axial pattern of xylem conduits similar to those evolved by dicots to compensate and minimize the negative effect of root-to-leaf length on hydrodynamic resistance to water flow.

  20. Protective coating as a factor to ensure the strength and hydraulic performance of recoverable pipelines

    Directory of Open Access Journals (Sweden)

    Orlov Vladimir Aleksandrovich

    2015-01-01

    Full Text Available The authors present an analysis of various types of internal protective pipeline coatings to ensure the strength and hydraulic characteristics of a remodeled pipeline and related coating methods for effective trenchless renovation of engineering systems, water supply systems and sanitation. As protective coating the authors considered a round profile tube of a smaller diameter than of the old pipe, close to the old pipe, sprayed lining on the basis of inorganic and inorganic materials. The article analyzes the methods of trenchless renovation for applying protective coatings: routing in the old pipeline of new pipes made of polymeric materials or polymeric sleeves, centrifugal spraying on the inner surface of pipelines’ inorganic and organic protective coatings. Special attention was paid to bag technology, providing the required strength properties at specific values of the modulus of elasticity and a number of external factors such as the depth of the existing pipe, the existence and magnitude of the horizon groundwater over it. Also attention is paid to the application technology of tape coatings ribbed profile on the inner surface of pipelines. This technology has a unique feature, which is the ability of recoverable pipeline functioning during its renovation by winding an endless belt and the formation of a new pipe. The tape coating winding is carried out by different types of spiral winding machines. The thickness of the protective coating layer forming the tube remains minimal. Inorganic cement-sand and organic coatings were considered as alternative options for repair of pipelines, which allow to localize the defects in the form of a fistula, minor cracks and other damages. However it is noted that a cement-sandy covering is inferior to organic, because it does not provide the strength characteristics of the pipeline system. The main advantage of the organic coating is mudding fistula of a large diameter, making a high wear

  1. Analyses and Comparison of Solar Air Heater with Various Rib Roughness using Computational Fluid Dynamics (CFD)

    Science.gov (United States)

    Kumar, K. Ravi; Cheepu, Muralimohan; Srinivas, B.; Venkateswarlu, D.; Pramod Kumar, G.; Shiva, Apireddi

    2018-03-01

    In solar air heater, artificial roughness on absorber plate become prominent technique to improving heat transfer rate of air flowing passage as a result of laminar sublayer. The selection of rib geometries plays important role on friction characteristics and heat transfer rate. Many researchers studying the roughness shapes over the years to investigate the effect of geometries on the performance of friction factor and heat transfer of the solar air heater. The present study made an attempt to develop the different rib shapes utilised for creating artificial rib roughness and its comparison to investigate higher performance of the geometries. The use of computational fluid dynamics software resulted in correlation of friction factor and heat transfer rate. The simulations studies were performed on 2D computational fluid dynamics model and analysed to identify the most effective parameters of relative roughness of the height, width and pitch on major considerations of friction factor and heat transfer. The Reynolds number is varied in a range from 3000 to 20000, in the current study and modelling has conducted on heat transfer and turbulence phenomena by using Reynolds number. The modelling results showed the formation of strong vortex in the main stream flow due to the right angle triangle roughness over the square, rectangle, improved rectangle and equilateral triangle geometries enhanced the heat transfer extension in the solar air heater. The simulation of the turbulence kinetic energy of the geometry suggests the local turbulence kinetic energy has been influenced strongly by the alignments of the right angle triangle.

  2. Plug & Play Control of Hydraulic Networks

    DEFF Research Database (Denmark)

    Jensen, Tom Nørgaard

    2012-01-01

    Process Control research program, which the work presented here is a part of. An industrial case study involving a large-scale hydraulic network with non-linear dynamics is studied. The hydraulic network underlies a district heating system, which provides heating water to a number of end-users in a city...... district. The case study considers a novel approach to the design of district heating systems in which the diameter of the pipes used in the system is reduced in order to reduce the heat losses in the system, thereby making it profitable to provide district heating to areas with low energy demands. The new...

  3. XROMM analysis of rib kinematics during lung ventilation in the green iguana, Iguana iguana.

    Science.gov (United States)

    Brainerd, Elizabeth L; Moritz, Sabine; Ritter, Dale A

    2016-02-01

    The three-dimensional rotations of ribs during breathing are typically described as bucket-handle rotation about a dorsoventrally oriented axis, pump-handle rotation about a mediolateral axis, and caliper rotation about a rostrocaudal axis. In amniotes with double-headed ribs, rib motion is constrained primarily to one degree-of-freedom (DOF) rotation about an axis connecting the two rib articulations. However, in Squamata, the ribs are single headed and the hemispherical costovertebral joints permit rotations with three DOF. In this study, we used X-ray reconstruction of moving morphology (XROMM ) to quantify rib rotation during deep breathing in four green iguanas. We found that rib rotation was strongly dominated by bucket-handle rotation, thus exhibiting nearly hinge-like motion, despite the potential for more complex motions. The vertebral and sternal segments of each rib did not deform measurably during breathing, but they did move relative to each other at a thin, cartilaginous intracostal joint. While standing still and breathing deeply, four individual iguanas showed variability in their rib postures, with two breathing around a highly inflated posture, and two breathing around a posture with the ribs folded halfway back. Bucket-handle rotations showed clear rostrocaudal gradients, with rotation increasing from the third cervical to the first or second dorsal rib, and then decreasing again caudally, a pattern that is consistent with the intercostal muscles in the rostral intercostal spaces being the primary drivers of inspiration. The constrained, primarily bucket-handle rotations observed here during breathing do not help to explain the evolution of permissive, hemispherical costovertebral joints in squamates from the more constrained, double-headed rib articulations of other amniotes. © 2016. Published by The Company of Biologists Ltd.

  4. Measurement of the aortic diameter in the asymptomatic Korean population: Assessment with multidetector CT

    International Nuclear Information System (INIS)

    Lee, Sang Hwan; Lee, Whal; Choi, Hyuck Jae; Kim, Dae Jin; Park, Eun Ah; Chung, Jin Wook; Park, Jae Hyung

    2013-01-01

    To determine normal reference values for aortic diameters in asymptomatic Korean adults. Three hundred adults without signs or symptoms of cardiovascular diseases were enrolled in this study. Aortic diameters were measured at nine predetermined levels on CT images. Aortic diameter measurements were adjusted for body surface area. Analysis of data was performed with regard to age, sex, weight, height and hypertension. Aortic diameters were 2.99 ± 0.57 cm at the ascending aorta, 2.54 ± 0.35 cm at the transverse aortic arch, 2.36 ± 0.35 cm at the proximal descending thoracic aorta (DTA), 2.23 ± 0.37 cm at the mid DTA, 2.17 ± 0.38 cm at the distal DTA, 2.16 ± 0.37 cm at the thoracoabdominal junction, 2.10, 00B1, 0.35 cm at the level of the celiac axis, 1.94, 00B1, 0.36 cm at the suprarenal aorta, 1.58 ± 0.24 cm at the aortic bifurcation. Men had slightly larger diameters than women (p < 0.05). All diameters increased with age and hypertension, with statistical significance (p < 0.01). And all aortic diameters increased with height (p < 0.05) except at the level of the aortic arch (p = 0.056), and increased with weight (p < 0.05) except at the level of the suprarenal aorta (p = 0.067). Male sex, higher weight and height, age and hypertension are associated with larger aortic diameters in asymptomatic Korean adults.

  5. Diagnostic significance of rib series in minor thorax trauma compared to plain chest film and computed tomography.

    Science.gov (United States)

    Hoffstetter, Patrick; Dornia, Christian; Schäfer, Stephan; Wagner, Merle; Dendl, Lena M; Stroszczynski, Christian; Schreyer, Andreas G

    2014-01-01

    Rib series (RS) are a special radiological technique to improve the visualization of the bony parts of the chest. The aim of this study was to evaluate the diagnostic accuracy of rib series in minor thorax trauma. Retrospective study of 56 patients who received RS, 39 patients where additionally evaluated by plain chest film (PCF). All patients underwent a computed tomography (CT) of the chest. RS and PCF were re-read independently by three radiologists, the results were compared with the CT as goldstandard. Sensitivity, specificity, negative and positive predictive value were calculated. Significance in the differences of findings was determined by McNemar test, interobserver variability by Cohens kappa test. 56 patients were evaluated (34 men, 22 women, mean age =61 y.). In 22 patients one or more rib fracture could be identified by CT. In 18 of these cases (82%) the correct diagnosis was made by RS, in 16 cases (73%) the correct number of involved ribs was detected. These differences were significant (p = 0.03). Specificity was 100%, negative and positive predictive value were 85% and 100%. Kappa values for the interobserver agreement was 0.92-0.96. Sensitivity of PCF was 46% and was significantly lower (p = 0.008) compared to CT. Rib series does not seem to be an useful examination in evaluating minor thorax trauma. CT seems to be the method of choice to detect rib fractures, but the clinical value of the radiological proof has to be discussed and investigated in larger follow up studies.

  6. Rib head protrusion into the central canal in type 1 neurofibromatosis

    International Nuclear Information System (INIS)

    Ton, Jimmy; Yen, Philip; Stein-Wexler, Rebecca; Gupta, Munish

    2010-01-01

    Intraspinal rib head dislocation is an important but under-recognized consequence of dystrophic scoliosis in patients with neurofibromatosis 1 (NF1). To present clinical and imaging findings of intraspinal rib head dislocation in NF1. We retrospectively reviewed clinical presentation, imaging, operative reports and post-operative courses in four NF1 patients with intraspinal rib head dislocation and dystrophic scoliosis. We also reviewed 17 cases from the English literature. In each of our four cases of intraspinal rib head dislocation, a single rib head was dislocated on the convex apex of the curve, most often in the mid- to lower thoracic region. Cord compression occurred in half of these patients. Analysis of the literature yielded similar findings. Only three cases in the literature demonstrates the MRI appearance of this entity; most employ CT. All of our cases include both MRI and CT; we review the subtle findings on MRI. Although intraspinal rib head dislocation is readily apparent on CT, sometimes MRI is the only cross-sectional imaging performed. It is essential that radiologists become familiar with this entity, as subtle findings have significant implications for surgical management. (orig.)

  7. Radiologic-anatomic correlation of thoracic vertebrae and rib shadows in chest digital radiograph

    International Nuclear Information System (INIS)

    Yamaguchi, Isao; Itoh, Harumi

    2007-01-01

    The purpose of this study was to provide an introduction to parsing the radiologic appearance of thoracic vertebrae and ribs. In the study, the radiologic-anatomic correlation technique was applied to promote further understanding of normal chest radiographs. The thoracic vertebrae and ribs of chest radiographs were compared with each macroscopic radiologic and computed tomography (CT) image. The rib parsed the linear shadow of the body of the rib. The macroscopic and radiologic images of thoracic vertebrae and ribs were evaluated to explain their normal radiologic findings. The results of such correlation were summarized as follows: The lamina of the vertebral arch was visualized due to anterior rotation of the upper thoracic vertebrae. The density ratio of the thoracic-vertebrae shadow was almost the same in the vertebral body and vertebral arch. The linear shadow superimposed on the rib corresponded to the inferior margin of the rib. The radiologic-anatomic correlation technique was useful to evaluate normal radiologic findings, and the study was useful to radiological technologists. (author)

  8. Post-accelerator LINAC design for the VECC RIB project

    Indian Academy of Sciences (India)

    acclerator type of RIB facility. The scheme utilises the existing = 130 room temperature variable energy cyclotron machine as the primary accelerator for the production of RIBs and radio frequency quadrupole (RFQ) and LINAC modules for ...

  9. Epidural analgesia in patients with traumatic rib fractures

    DEFF Research Database (Denmark)

    Duch, P; Møller, M H

    2015-01-01

    BACKGROUND: Traumatic rib fractures are a common condition associated with considerable morbidity and mortality. Observational studies have suggested improved outcome in patients receiving continuous epidural analgesia (CEA). The aim of the present systematic review of randomised controlled trials...... (RCTs) was to assess the benefit and harm of CEA compared with other analgesic interventions in patients with traumatic rib fractures. METHODS: We performed a systematic review with meta-analysis and trial sequential analysis (TSA). Eligible trials were RCTs comparing CEA with other analgesic...... interventions in patients with traumatic rib fractures. Cumulative relative risks (RRs) and mean differences (MDs) with 95% confidence intervals (CIs) were estimated, and risk of systematic and random errors was assessed. The predefined primary outcome measures were mortality, pneumonia and duration...

  10. Flow instability and critical heat flux in a ribbed annulus

    International Nuclear Information System (INIS)

    Yang, B.W.; Dougherty, T.; Fighetti, C.; Kokolis, S.; Reddy, G.D.; McAssey, E.V. Jr.; Coutts, A.

    1993-01-01

    An experimental program has been conducted to determine the onset of flow instability point in a heated annulus which is divided into four sub channels by non-conducting ribs. The onset of flow instability is identified by the minimum point in the pressure drop-velocity curve. Comparison with a ribless annulus show that the presence of ribs increases the minimum point velocity. In addition, data are presented which show that under certain conditions premature CHF can be induced by the ribs

  11. Tracheid diameter is the key trait determining the extent of freezing-induced embolism in conifers.

    Science.gov (United States)

    Pittermann, Jarmila; Sperry, John

    2003-09-01

    We tested the hypotheses that freezing-induced embolism is related to conduit diameter, and that conifers and angiosperms with conduits of equivalent diameter will exhibit similar losses of hydraulic conductivity in response to freezing. We surveyed the freeze-thaw response of conifers with a broad range of tracheid diameters by subjecting wood segments (root, stem and trunk wood) to a freeze-thaw cycle at -0.5 MPa in a centrifuge. Embolism increased as mean tracheid diameter exceeded 30 microm. Tracheids with a critical diameter greater than 43 microm were calculated to embolize in response to freezing and thawing at a xylem pressure of -0.5 MPa. To confirm that freezing-induced embolism is a function of conduit air content, we air-saturated stems of Abies lasiocarpa (Hook.) Nutt. (mean conduit diameter 13.7 +/- 0.7 microm) by pressurizing them 1 to 60 times above atmospheric pressure, prior to freezing and thawing. The air saturation method simulated the effect of increased tracheid size because the degree of super-saturation is proportional to a tracheid volume holding an equivalent amount of dissolved air at ambient pressure. Embolism increased when the dissolved air content was equivalent to a mean tracheid diameter of 30 microm at ambient air pressure. Our centrifuge and air-saturation data show that conifers are as vulnerable to freeze-thaw embolism as angiosperms with equal conduit diameter. We suggest that the hydraulic conductivity of conifer wood is maximized by increasing tracheid diameters in locations where freezing is rare. Conversely, the narrowing of tracheid diameters protects against freezing-induced embolism in cold climates.

  12. The value of multislice helical CT in the diagnosis of the rib micro-fracture

    International Nuclear Information System (INIS)

    Wang Shuli; Wang Linsen; Sun Dingyuan; Deng Xin; Geng Xin; Li Jian; Liu Zhigang; Guo Lin; Jia Zhihong

    2005-01-01

    Objective: To evaluate the clinical value of MSCT with thin-section reconstruction and curved multiplanar reformation of rib micro-fracture. Methods: Thirty-eight patients suspected ribs fracture by clinical examination, which had negative appearance in X-ray film, were performed with MSCT scan with thin-section reconstructed and curved multiplanar reformation. The imaging of 5 mm, 1 mm thickness and curved reformatted imags were analysed by three groups of radiologists respectively. Results: Of the 38 patients, 26 patients were demonstrated ribs fracture with 1 mm thin-section reconstructed and curved multiplanar reformatted CT imaging, which were classified as complete fracture in 18 ribs and incomplete fracture in 41 ribs. The ends of the fractures displacement located within a distance of double-thickness of the cortex of the complete ribs fracture. With 5 mm thickness imaging, the accuracy of the diagnosis was 86.4%, 89.8% and 94.9% by three groups radiologists, respectively. Conclusion: The rib fracture is very common in clinic, the incomplete and non evident displacement complete ribs fracture are difficult to be diagnosed by plain radiography. The MSCT can produce a large range volume information scan. Thin-section reconstructed and curved multiplanar reformatted imaging should be the effective method in diagnosis of ribs fracture. The total rib pattern and location, extend of all the ribs fracture in this cases can be displayed in one scan by the curved multiplanar reformatted imaging. (authors)

  13. Parameters Analysis of Hydraulic-Electrical Energy Regenerative Absorber on Suspension Performance

    Directory of Open Access Journals (Sweden)

    Han Zhang

    2014-05-01

    Full Text Available To recycle the vibration energy of vehicles over rough roads, a hydraulic-electricity energy regenerative suspension (HEERS was designed in the present work, and simulations were performed with focus on its performance. On the basis of the system principle, the mathematical model of hydraulic-electrical energy regenerative absorber (HEERA and two degrees of freedom (DOF suspension dynamic model were constructed. Using the model of HEERA, simulations on force-displacement and force-velocity characteristics were performed with a 1.67 Hz frequency and a sinusoidal input adopted. And then in combination with HEERA model and two DOF suspension models, simulations on the performance of HEERS also were carried out. Finally, the influences of charging pressure and volume of the accumulator, hydraulic motor displacement, orifice area of check valve, and inner diameter of hydraulic pipelines on the performance of HEERA and HEERS were investigated in depth. The simulation results indicated that (i the damping characteristic of HEERA was coincident with the damping characteristics of traditional absorber; (ii the most remarkable influencing factor on the performance of HEERS was the hydraulic motor displacement, followed by orifice area of check valve, inner diameter of pipelines, and charging pressure of accumulator, while the effects of charging volume of accumulator were quite limited.

  14. Flavin binding to the high affinity riboflavin transporter RibU

    NARCIS (Netherlands)

    Duurkens, Hinderika; Tol, Menno B.; Geertsma, Eric R.; Permentier, Hjalmar P.; Slotboom, Dirk Jan

    2007-01-01

    The first biochemical and spectroscopic characterization of a purified membrane transporter for riboflavin ( vitamin B-2) is presented. The riboflavin transporter RibU from the bacterium Lactococcus lactis was overexpressed, solubilized, and purified. The purified transporter was bright yellow when

  15. Cronkhite-Canada syndrome associated with rib fractures: a case report

    Directory of Open Access Journals (Sweden)

    Wan Haijun

    2010-10-01

    Full Text Available Abstract Background Cronkhite-Canada syndrome (CCS is a rare multiple gastrointestinal polyposis. Up till now, many complications of CCS have been reported in the literature, but rib fracture is not included. Case Presentation We report a case of a 58-year-old man who was admitted to our hospital with a 6-month history of frequent diarrhea, intermittent hematochezia and a weight loss of 13 kg. On admission, physical examination revealed alopecia of the scalp, hyperpigmentation of the hands and soles, and dystrophy of the fingernails. Laboratory data revealed hypocalcaemia and hypoproteinemia. Esophagogastroduodenoscopy, video capsule endoscopy and colonoscopy revealed various sizes of generalized gastrointestinal polyps. Histological examination of the biopsy specimens obtained from the stomach and the colon showed adenomatous polyp and inflammatory polyp respectively. Thus, a diagnosis of CCS was made. After treatment with corticosteroids for 24 days and nutritional support for two months, his clinical condition improved. Two months later, he was admitted to our hospital for the second time with frequent diarrhea and weight loss. The chest radiography revealed fractures of the left sixth and seventh ribs. Examinations, including emission computed tomography, bone densitometry test, and other serum parameters, were performed, but could not identify the definite etiology of the rib fractures. One month later, the patient suffered from aggravating multiple rib fractures due to the ineffective treatment, persistent hypocalcaemia and malnutrition. Conclusions This is the first case of a CCS patient with multiple rib fractures. Although the association between CCS and multiple rib fractures in this case remains uncertain, we presume that persistent hypocalcaemia and malnutrition contribute to this situation, or at least aggravate this rare complication. Besides, since prolonged corticosteroid therapy will result in an increased risk of osteoporotic

  16. Cronkhite-Canada syndrome associated with rib fractures: a case report.

    Science.gov (United States)

    Yuan, Bosi; Jin, Xinxin; Zhu, Renmin; Zhang, Xiaohua; Liu, Jiong; Wan, Haijun; Lu, Heng; Shen, Yunzhu; Wang, Fangyu

    2010-10-18

    Cronkhite-Canada syndrome (CCS) is a rare multiple gastrointestinal polyposis. Up till now, many complications of CCS have been reported in the literature, but rib fracture is not included. We report a case of a 58-year-old man who was admitted to our hospital with a 6-month history of frequent diarrhea, intermittent hematochezia and a weight loss of 13 kg. On admission, physical examination revealed alopecia of the scalp, hyperpigmentation of the hands and soles, and dystrophy of the fingernails. Laboratory data revealed hypocalcaemia and hypoproteinemia. Esophagogastroduodenoscopy, video capsule endoscopy and colonoscopy revealed various sizes of generalized gastrointestinal polyps. Histological examination of the biopsy specimens obtained from the stomach and the colon showed adenomatous polyp and inflammatory polyp respectively. Thus, a diagnosis of CCS was made. After treatment with corticosteroids for 24 days and nutritional support for two months, his clinical condition improved. Two months later, he was admitted to our hospital for the second time with frequent diarrhea and weight loss. The chest radiography revealed fractures of the left sixth and seventh ribs. Examinations, including emission computed tomography, bone densitometry test, and other serum parameters, were performed, but could not identify the definite etiology of the rib fractures. One month later, the patient suffered from aggravating multiple rib fractures due to the ineffective treatment, persistent hypocalcaemia and malnutrition. This is the first case of a CCS patient with multiple rib fractures. Although the association between CCS and multiple rib fractures in this case remains uncertain, we presume that persistent hypocalcaemia and malnutrition contribute to this situation, or at least aggravate this rare complication. Besides, since prolonged corticosteroid therapy will result in an increased risk of osteoporotic fracture, CCS patients who accept corticosteroid therapy could be

  17. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures

    OpenAIRE

    Gulbahar, Gultekin; Kaplan, Tevfik; Turker, Hasan Bozkurt; Gundogdu, Ahmet Gokhan; Han, Serdar

    2015-01-01

    First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare en...

  18. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures.

    Science.gov (United States)

    Gulbahar, Gultekin; Kaplan, Tevfik; Turker, Hasan Bozkurt; Gundogdu, Ahmet Gokhan; Han, Serdar

    2015-01-01

    First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare entity.

  19. Morbidity, mortality, associated injuries, and management of traumatic rib fractures

    Directory of Open Access Journals (Sweden)

    Frank Cheau-Feng Lin

    2016-06-01

    Conclusion: The severity of traumatic rib fractures was identified in this study. Therefore, a trauma team needs better preparation to provide effective treatment strategies when encountering thoracic trauma patients, especially patients who are older and have rib fractures.

  20. Hydraulic jumps in a channel

    DEFF Research Database (Denmark)

    Bonn, D.; Andersen, Anders Peter; Bohr, Tomas

    2009-01-01

    We present a study of hydraulic jumps with flow predominantly in one direction, created either by confining the flow to a narrow channel with parallel walls or by providing an inflow in the form of a narrow sheet. In the channel flow, we find a linear height profile upstream of the jump as expected......'s mixing-length theory with a mixing length that is proportional to the height of the fluid layer. Using averaged boundary-layer equations, taking into account the friction with the channel walls and the eddy viscosity, the flow both upstream and downstream of the jump can be understood. For the downstream...... subcritical flow, we assume that the critical height is attained close to the channel outlet. We use mass and momentum conservation to determine the position of the jump and obtain an estimate which is in rough agreement with our experiment. We show that the averaging method with a varying velocity profile...

  1. HYDRAULIC ELEVATOR INSTALLATION ESTIMATION FOR THE WATER SOURCE WELL SAND-PACK CLEANING UP

    Directory of Open Access Journals (Sweden)

    V. V. Ivashechkin

    2016-01-01

    Full Text Available The article offers design of a hydraulic elevator installation for cleaning up water-source wells of sand packs. It considerers the installation hydraulic circuit according to which the normal pump feeds the high-level tank water into the borehole through two parallel water lines. The water-jet line with washing nozzle for destroying the sand-pack and the supply pipe-line coupled with the operational nozzle of the hydraulic elevator containing the inlet and the supply pipelines for respectively intaking the hydromixture and removing it from the well. The paper adduces equations for fluid motion in the supply and the water-jet pipelines and offers expressions for evaluating the required heads in them. For determining water flow in the supply and the water-jet pipe lines the author proposes to employ graphical approach allowing finding the regime point in Q–H chart by means of building characteristics of the pump and the pipe-lines. For calculating the useful vertical head, supply and dimensions of the hydraulic elevator the article employs the equation of motion quantity with consistency admission of the motion quantity before and after mixing the flows in the hydraulic elevator. The suggested correlations for evaluating the hydraulic elevator efficiency determine the sand pack removal duration as function of its sizes and the ejected fluid flow rate. A hydraulic-elevator installation parameters estimation example illustrates removing a sand pack from a water-source borehole of 41 m deep and 150 mm diameter bored in the village of Uzla of Myadelsk region, of Minsk oblast. The working efficiency of a manufactured and laboratory tested engineering prototype of the hydraulic elevator installation was acknowledged in actual tests at the indicated borehole site. With application of graphical approach, the suggested for the hydraulic elevator installation parameters calculation procedure allows selecting, with given depth and the borehole diameter

  2. First rib fractures as an indicator of injury severity in major trauma

    OpenAIRE

    Sammy, I.A.; Chatha, H.; Lecky, F.; Bouamra, O.; Fragoso Iniguez, M.; Sattout, A.; Hickey, M.

    2016-01-01

    Introduction First rib fractures are traditionally considered indicators of increased morbidity and mortality in major trauma. However, this relationship has not been definitively proven. With an increase in computed tomography in major trauma, and the likely increase in detection of first rib fractures, this study re-evaluates whether first rib fractures are an indicator of injury severity. Discussion This study suggests that major trauma patients with first rib fractures have increased ISS ...

  3. Determination of body diameters of babies, children and adolescents to list exposure values in X-ray diagnostics and estimation of organ dose values for typical X-ray examinations

    International Nuclear Information System (INIS)

    Bohmann, I.

    1990-04-01

    Measurements of body diameters of children did not exist as yet. Therefore the body diameters of 270 children, male and female, were measured, together with weight and height. The children were healthy and chosen at random. Six groups regarding age were considered: Newborn, one, five, seven, ten, fifteen years old. From the measurements mean values and standard deviations were calculated. In addition the correlations of the body diameters with age, weight, and height were investigated. The mean values of weight and height were compared to literature data. Exposure tables for children now, for the first time, can be established on the basis of empirical results. (orig.) [de

  4. Rib fractures in coronary bypass patients: radionuclide detection

    International Nuclear Information System (INIS)

    Greenwald, L.V.; Baisden, C.E.; Symbas, P.N.

    1983-01-01

    Sternal retraction can cause the first rib to be fractured posteriorly, injuring the brachial plexus. The authors conducted bone scans of 24 consecutive open-heart surgery patients and found an unexpectedly high number of rib fractures which in all but one case had not been seen on the chest radiograph. Bone scans are recommended whenever there is unexplained non-incisional pain in a patient who has undergone sternal retraction

  5. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures

    Directory of Open Access Journals (Sweden)

    Gultekin Gulbahar

    2015-01-01

    Full Text Available First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare entity.

  6. Capacity of textile filters for wastewater Treatment at changeable wastewater level – a hydraulic model

    Directory of Open Access Journals (Sweden)

    Marcin Spychała

    2016-12-01

    Full Text Available The aim of the study was to describe in a mathematical manner the hydraulic capacity of textile filters for wastewater treatment at changeable wastewater levels during a period between consecutive doses, taking into consideration the decisive factors for flow-conditions of filtering media. Highly changeable and slightly changeable flow-conditions tests were performed on reactors equipped with non-woven geo-textile filters. Hydraulic conductivity of filter material coupons was determined. The dry mass covering the surface and contained in internal space of filtering material was then indicated and a mathematical model was elaborated. Flow characteristics during the highly changeable flow-condition test were sensitivity to differentiated values of hydraulic conductivity in horizontal zones of filtering layer. During the slightly changeable flow-conditions experiment the differences in permeability and hydraulic conductivity of different filter (horizontal zones height regions were much smaller. The proposed modelling approach in spite of its simplicity provides a satisfactory agreement with empirical data and therefore enables to simulate the hydraulic capacity of vertically oriented textile filters. The mathematical model reflects the significant impact of the filter characteristics (textile permeability at different filter height and operational conditions (dosing frequency on the textile filters hydraulic capacity.

  7. Frequency of intrathoracic injuries in children younger than 3 years with rib fractures.

    Science.gov (United States)

    Darling, Stephen E; Done, Stephen L; Friedman, Seth D; Feldman, Kenneth W

    2014-10-01

    Research documents that among children admitted to trauma intensive care units the number of rib fractures sustained indicates the child's likelihood of having and severity of intrathoracic injury. This has been misused in court to argue that children with multiple rib fractures who lack intrathoracic injury have abnormal bone fragility rather than inflicted injury. To determine frequency of intrathoracic injuries in children younger than 3 years with rib fractures in cases of child abuse and accidental trauma. We conducted a retrospective review of rib fractures caused by documented abuse or accidents from 2003 to 2010 in children treated at Seattle Children's Hospital and Harborview Medical Center. A senior pediatric radiologist and radiology fellow independently reviewed the imaging. Children with bone demineralization were excluded. Descriptive and simple comparative statistics were used. Seventy-two percent (47/65) of infants and toddlers with rib fractures were abused. Abused children had more rib fractures than accidentally injured children (5.55 vs. 3.11, P = 0.012). However intrathoracic injuries as a whole (55.6% vs. 12.8%, P fractures were equally frequent, but other extrathoracic fractures were more common with abuse (70.2% vs. 16.7%, P rib fractures than accidentally injured peers. This likely reflects different injury mechanics. Lack of intrathoracic injuries in abused children with rib fractures does not imply bone fragility.

  8. Fixation of a human rib by an intramedullary telescoping splint anchored by bone cement.

    Science.gov (United States)

    Liovic, Petar; Šutalo, Ilija D; Marasco, Silvana F

    2016-09-01

    A novel concept for rib fixation is presented that involves the use of a bioresorbable polymer intramedullary telescoping splint. Bone cement is used to anchor each end of the splint inside the medullary canal on each side of the fracture site. In this manner, rib fixation is achieved without fixation device protrusion from the rib, making the splint completely intramedullary. Finite element analysis is used to demonstrate that such a splint/cement composite can preserve rib fixation subjected to cough-intensity force loadings. Computational fluid dynamics and porcine rib experiments were used to study the anchor formation process required to complete the fixation.

  9. Separation and pattern formation in hydraulic jumps

    DEFF Research Database (Denmark)

    Bohr, Tomas; Ellegaard, C.; Hansen, A. Espe

    1998-01-01

    We present theory and experiments on the circular hydraulic jump in the stationary regime. The theory can handle the situation in which the fluid flows over an edge far away from the jump. In the experiments the external height is controlled, and a series of transitions in the flow structure appe...

  10. The number of displaced rib fractures is more predictive for complications in chest trauma patients.

    Science.gov (United States)

    Chien, Chih-Ying; Chen, Yu-Hsien; Han, Shih-Tsung; Blaney, Gerald N; Huang, Ting-Shuo; Chen, Kuan-Fu

    2017-02-28

    Traumatic rib fractures can cause chest complications that need further treatment and hospitalization. We hypothesized that an increase in the number of displaced rib fractures will be accompanied by an increase in chest complications. We retrospectively reviewed the trauma registry between January 2013 and May 2015 in a teaching hospital in northeastern Taiwan. Patients admitted with chest trauma and rib fractures without concomitant severe brain, splenic, pelvic or liver injuries were included. The demographic data, such as gender, age, the index of coexistence disease, alcohol consumption, trauma mechanisms were analyzed as potential predictors of pulmonary complications. Pulmonary complications were defined as pneumothorax, hemothorax, flail chest, pulmonary contusion, and pneumonia. In the 29 months of the study period, a total of 3151 trauma patients were admitted to our hospital. Among them, 174 patients were enrolled for final analysis. The most common trauma mechanism was road traffic accidents (58.6%), mainly motorbike accidents (n = 70, 40.2%). Three or more displaced rib fractures had higher specificity for predicting complications, compared to three or more total rib fractures (95.5% vs 59.1%). Adjusting the severity of chest trauma using TTSS and Ribscore by multivariable logistic regression analysis, we found that three or more rib fractures or any displaced rib fracture was the most significant predictor for developing pulmonary complication (aOR: 5.49 95% CI: 1.82-16.55). Furthermore, there were 18/57 (31.6%) patients with fewer than three ribs fractures developed pulmonary complications. In these 18 patients, only five patients had delayed onset complications and four of them had at least one displaced rib fracture. In this retrospective cohort study, we found that the number of displaced or total rib fractures, bilateral rib fractures, and rib fractures in more than two areas were associated with the more chest complications. Furthermore

  11. Compressive rib fracture: peri-mortem and post-mortem trauma patterns in a pig model.

    Science.gov (United States)

    Kieser, Jules A; Weller, Sarah; Swain, Michael V; Neil Waddell, J; Das, Raj

    2013-07-01

    Despite numerous studies on high impact fractures of ribs, little is known about compressive rib injuries. We studied rib fractures from a biomechanical and morphological perspective using 15, 5th ribs of domestic pigs Sus scrofa, divided into two groups, desiccated (representing post-mortem trauma) and fresh ribs with intact periosteum (representing peri-mortem trauma). Ribs were axially compressed and subjected to four-point bending in an Instron 3339 fitted with custom jigs. Morphoscopic analysis of resultant fractures consisted of standard optical methods, micro-CT (μCT) and scanning electron microscopy (SEM). During axial compression, fresh ribs had slightly higher strength because of energy absorption capabilities of their soft and fluidic components. In flexure tests, dry ribs showed typical elastic-brittle behaviour with long linear load-extension curves, followed by relatively short non-linear elastic (hyperelastic) behaviour and brittle fracture. Fresh ribs showed initial linear-elastic behaviour, followed by strain softening, visco-plastic responses. During the course of loading, dry bone showed minimal observable damage prior to the onset of unstable fracture. In contrast, fresh bone showed buckling-like damage features on the compressive surface and cracking parallel to the axis of the bone. Morphologically, all dry ribs fractured precipitously, whereas all but one of the fresh ribs showed incomplete fracture. The mode of fracture, however, was remarkably similar for both groups, with butterfly fractures predominating (7/15, 46.6% dry and wet). Our study highlights the fact that under controlled loading, despite seemingly similar butterfly fracture morphology, fresh ribs (representing perimortem trauma) show a non-catastrophic response. While extensive strain softening observed for the fresh bone does show some additional micro-cracking damage, it appears that the periosteum may play a key role in imparting the observed pseudo-ductility to the ribs

  12. Regional Models of Diameter as a Function of Individual Tree Attributes, Climate and Site Characteristics for Six Major Tree Species in Alberta, Canada

    Directory of Open Access Journals (Sweden)

    Dan A. MacIsaac

    2011-09-01

    Full Text Available We investigated the relationship of stem diameter to tree, site and stand characteristics for six major tree species (trembling aspen, white birch, balsam fir, lodgepole pine, black spruce, and white spruce in Alberta (Canada with data from Alberta Sustainable Resource Development Permanent Sample Plots. Using non-linear mixed effects modeling techniques, we developed models to estimate diameter at breast height using height, crown and stand attributes. Mixed effects models (with plot as subject using height, crown area, and basal area of the larger trees explained on average 95% of the variation in diameter at breast height across the six species with a root mean square error of 2.0 cm (13.4% of mean diameter. Fixed effects models (without plot as subject including the Natural Sub-Region (NSR information explained on average 90% of the variation in diameter at breast height across the six species with a root mean square error equal to 2.8 cm (17.9% of mean diameter. Selected climate variables provided similar results to models with NSR information. The inclusion of nutrient regime and moisture regime did not significantly improve the predictive ability of these models.

  13. Attempts to isolate a horizontal high diameter (300 mm nominal diameter) pipeline with an ice plug at minimum water flow and without water flow

    International Nuclear Information System (INIS)

    Corbescu, B.; Gyongyosi, T.; Puiu, D.; Panaitescu, V. N.

    2016-01-01

    The ice plug isolation technique used for high diameter horizontal pipes is used for repair and maintenance activities on hydraulic installations that use liquid working agents. These techniques do not require shutting down the entire plant. The ice plug development inside the pipe requires using custom specialized equipment for each individual application. This paper briefly describes the experimental technological facilities used for conducting the experiments and highlights the important aspects in an experiment conducted on a horizontal NPS 12 testing section running demineralized water followed by the result analysis and conclusions. The paper is dedicated to specialists working in research and technological engineering. (authors)

  14. Pitfalls associated with open reduction and internal fixation of fractured ribs.

    Science.gov (United States)

    Sarani, Babak; Schulte, Leah; Diaz, Jose J

    2015-12-01

    Rib fracture is exceedingly common and remains a leading cause of death in patients with chest injury. Probability of death increases by 19% with each broken rib, and the probability of death increases further with age. Treatment is centered on pain control and early mobilization to provide adequate pulmonary hygiene. Multimodality interventions, such as incentive spirometry, postural changes, and coughing, are pivotal in minimizing the risk of pneumonia and death. Recently, many studies have found mortality benefit to operation fixation (ORIF) of ribs in select patients. However, this procedure remains underutilized partly due to lack of familiarity with its technique and pitfalls by trauma surgeons, in particular. Whereas there are publications on operative technique, there are no studies describing pitfalls associated with this procedure. The purpose of this paper is to describe pitfalls on the technical aspects of ORIF of the ribs based on the medical literature where possible and based on our experience in instances where peer reviewed evidence is lacking. The paper is not meant to serve as a protocol for managing rib fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Rib fractures after percutaneous radiofrequency and microwave ablation of lung tumors: incidence and relevance.

    Science.gov (United States)

    Alexander, Erica S; Hankins, Carol A; Machan, Jason T; Healey, Terrance T; Dupuy, Damian E

    2013-03-01

    To retrospectively identify the incidence and probable risk factors for rib fractures after percutaneous radiofrequency ablation (RFA) and microwave ablation (MWA) of neoplasms in the lung and to identify complications related to these fractures. Institutional review board approval was obtained for this HIPAA-compliant retrospective study. Study population was 163 patients treated with MWA and/or RFA for 195 lung neoplasms between February 2004 and April 2010. Follow-up computed tomographic images of at least 3 months were retrospectively reviewed by board-certified radiologists to determine the presence of rib fractures. Generalized estimating equations were performed to assess the effect that patient demographics, tumor characteristics, treatment parameters, and ablation zone characteristics had on development of rib fractures. Kaplan-Meier curve was used to estimate patients' probability of rib fracture after ablation as a function of time. Clinical parameters (ie, pain in ribs or chest, organ damage caused by fractured rib) were evaluated for patients with confirmed fracture. Rib fractures in proximity to the ablation zone were found in 13.5% (22 of 163) of patients. Estimated probability of fracture was 9% at 1 year and 22% at 3 years. Women were more likely than were men to develop fracture after ablation (P = .041). Patients with tumors closer to the chest wall were more likely to develop fracture (P = .0009), as were patients with ablation zones that involved visceral pleura (P = .039). No patients with rib fractures that were apparently induced by RFA and MWA had organ injury or damage related to fracture, and 9.1% (2 of 22) of patients reported mild pain. Rib fractures were present in 13.5% of patients after percutaneous RFA and MWA of lung neoplasms. Patients who had ablations performed close to the chest wall should be monitored for rib fractures.

  16. Analysis of the Effect of Osteon Diameter on the Potential Relationship of Osteocyte Lacuna Density and Osteon Wall Thickness

    Science.gov (United States)

    Skedros, John G.; Clark, Gunnar C.; Sorenson, Scott M.; Taylor, Kevin W.; Qiu, Shijing

    2011-01-01

    An important hypothesis is that the degree of infilling of secondary osteons (Haversian systems) is controlled by the inhibitory effect of osteocytes on osteoblasts, which might be mediated by sclerostin (a glycoprotein produced by osteocytes). Consequently, this inhibition could be proportional to cell number: relatively greater repression is exerted by progressively greater osteocyte density (increased osteocytes correlate with thinner osteon walls). This hypothesis has been examined, but only weakly supported, in sheep ulnae. We looked for this inverse relationship between osteon wall thickness (On.W.Th) and osteocyte lacuna density (Ot.Lc.N/B.Ar) in small and large osteons in human ribs, calcanei of sheep, deer, elk, and horses, and radii and third metacarpals of horses. Analyses involved: (1) all osteons, (2) smaller osteons, either ≤150μm diameter or ≤ the mean diameter, and (3) larger osteons (>mean diameter). Significant, but weak, correlations between Ot.Lc.N/B.Ar and On.W.Th/On.Dm (On.Dm = osteon diameter) were found when considering all osteons in limb bones (r values −0.16 to −0.40, psheep ulnae: r= −0.39, pbone types) or very weak (two/seven bone types). In ribs, a negative relationship was only found in smaller osteons (r= −0.228, p<0.01); this inverse relationship in smaller osteons did not occur in elk calcanei. These results do not provide clear or consistent support for the hypothesized inverse relationship. However, correlation analyses may fail to detect osteocyte-based repression of infilling if the signal is spatially non-uniform (e.g., increased near the central canal). PMID:21809466

  17. The effect of internal ribbing on forced convective heat transfer in circular-sectioned tubes

    International Nuclear Information System (INIS)

    Farhadi Rahmat-Abadi, K.; Morris, W. D.

    2003-01-01

    This paper presents the results of an experimental examination of the effect of internal circumferential ribs on forced convection in circular-sectioned tubes. The work is relevant to the internal cooling of gas turbine rotor blades. The influence of rib geometry is investigated for three different rib configurations and simple design-type, empirical equations are developed for estimating heat transfer at rib and mid-rib locations. It is demonstrated that heat transfer may be improved by up to three fold in relation to fully developed forced convection in smooth-walled tubes. The geometric parameters which have been used for the experiments are typical of those currently applied to gas turbine blade cooling designs

  18. A comparison of the CHF between tubes and annuli under PWR thermal-hydraulic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Herer, C. [RRAMATOME EP/TC, Paris (France); Souyri, A. [EdF DER/RNE/TTA, Chatou (France); Garnier, J. [CEA DRN/DTP/STR/LETC, Grenoble (France)

    1995-09-01

    Critical Heat Flux (CHF) tests were carried out in three tubes with inside diameters of 8, 13, and 19.2 mm and in two annuli with an inner tube of 9.5 mm and an outer tube of 13 or 19.2 mm. All axial heat flux distributions in the test sections were uniform. The coolant fluid was Refrigerant 12 (Freon-12) under PWR thermal-hydraulic conditions (equivalent water conditions - Pressure: 7 to 20 MPa, Mass Velocity: 1000 to 6000 kg/m2/s, Local Quality: -75% to +45%). The effect of tube diameter is correlated for qualities under 15%. The change from the tube to the annulus configuration is correctly taken into account by the equivalent hydraulic diameter. Useful information is also provided concerning the effect of a cold wall in an annulus.

  19. Micro-hydromechanical deep drawing of metal cups with hydraulic pressure effects

    Science.gov (United States)

    Luo, Liang; Jiang, Zhengyi; Wei, Dongbin; Wang, Xiaogang; Zhou, Cunlong; Huang, Qingxue

    2018-03-01

    Micro-metal products have recently enjoyed high demand. In addition, metal microforming has drawn increasing attention due to its net-forming capability, batch manufacturing potential, high product quality, and relatively low equipment cost. Micro-hydromechanical deep drawing (MHDD), a typical microforming method, has been developed to take advantage of hydraulic force. With reduced dimensions, the hydraulic pressure development changes; accordingly, the lubrication condition changes from the macroscale to the microscale. A Voronoi-based finite element model is proposed in this paper to consider the change in lubrication in MHDD according to open and closed lubricant pocket theory. Simulation results agree with experimental results concerning drawing force. Changes in friction significantly affect the drawing process and the drawn cups. Moreover, defined wrinkle indexes have been shown to have a complex relationship with hydraulic pressure. High hydraulic pressure can increase the maximum drawing ratio (drawn cup height), whereas the surface finish represented by the wear is not linearly dependent on the hydraulic pressure due to the wrinkles.

  20. When Should Abdominal Computed Tomography Be Considered in Patients with Lower Rib Fractures?

    Science.gov (United States)

    Jeroukhimov, Igor; Hershkovitz, Yehuda; Wiser, Itay; Kessel, Boris; Ayyad, Mohammed; Gatot, Inbar; Shapira, Zahar; Jeoravlev, Svetlana; Halevy, Ariel; Lavy, Ron

    2017-05-01

    Lower rib fractures are considered as a marker of intra-abdominal organ injury. Abdominal computed tomography (CT) is the "gold standard" examination for patients with lower rib fractures. However, the reported incidence of concomitant intra-abdominal injuries (IAI) is 20%-40%. The purpose of this study was to evaluate the incidence of intra-abdominal organ injuries in blunt trauma patients with lower rib fractures. Medical charts and radiology reports of patients with lower rib (from the 8th to 12th rib) fractures admitted to our center during a 6-year period were retrospectively reviewed. Patients were divided into two groups. Group I included patients with intra-abdominal injury (IAI) diagnosed either by CT or on urgent laparotomy, and Group II included those with normal abdominal CT scans. Data included demographics, mechanism of injury, laboratory tests, radiology results including number and location of fractured ribs, and incidence of IAI. Overall 318 patients were included in the study. Fifty-seven patients (17.9%) had 71 IAIs compared with 265 (82.1%) patients with no IAI. Logistic regression identified age younger than 55 years (relative risk [RR] = 7.2; 95% confidence interval [CI] 3.1-16.8; p = 0.001), bilateral rib fractures (RR = 3.9; 95% CI 1.1-13.5; p = 0.03) and decreased levels of hematocrit (RR = 2.4; 95% CI 1.2-4.8; p = 0.016) as independent risk factors for the presence of IAI. Abdominal CT should be considered in blunt trauma patients with lower rib fractures who are younger than 55 years of age and have bilateral rib fractures and decreased levels of hematocrit on admission. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Trial of Injected Liposomal Bupivacaine vs Bupivacaine Infusion After Surgical Stabilization of Rib Fractures

    Science.gov (United States)

    2017-10-06

    Drug Effect; Rib Fractures; Rib Trauma; Surgical Procedure, Unspecified; Pain; Catheter (Other); Nerve Pain; Local Infiltration; Anesthesia, Local; Intercostal Rib; Opioid Dependence; Chest Injury Trauma; Pneumonia

  2. Sternoplasty and rib distraction in neonatal Jeune syndrome.

    LENUS (Irish Health Repository)

    Conroy, Eimear

    2010-09-01

    A 12-week-old boy with Jeune syndrome (asphyxiating thoracic dystrophy) was referred to the orthopaedic unit with progressive respiratory failure, recurrent respiratory tract infections, and recurrent admissions to the intensive care unit for ventilatory support. His chest x-ray revealed a small and narrow thoracic cage with short broad ribs and abnormal costal cartilages. His chest expansion was impaired by the short, horizontally positioned ribs resulting in alveolar hypoventilation. Without surgical intervention to expand his thoracic cage, he would die of respiratory failure.

  3. Preoperative three-dimensional printing for surgical stabilization of rib fractures

    Directory of Open Access Journals (Sweden)

    Wei-Chun Lin

    2018-01-01

    Full Text Available Pulmonary trauma is a significant cause of morbidity and mortality in patients with major trauma. Chest wall contusion with rib fracture is very common. Surgical stabilization of rib fracture (SSRF has traditionally required an exploratory thoracotomy for adequate exposure. Minimally invasive approaches for SSRF are now being developed. However, preoperative localization of rib fractures and intraoperative designing of titanium plates require additional time. We present a novel technique involving three-dimensional printing for promoting SSRF with a minimally invasive approach that is efficient and provides good patient outcomes.

  4. A prospective, controlled clinical evaluation of surgical stabilization of severe rib fractures.

    Science.gov (United States)

    Pieracci, Fredric M; Lin, Yihan; Rodil, Maria; Synder, Madelyne; Herbert, Benoit; Tran, Dong Kha; Stoval, Robert T; Johnson, Jeffrey L; Biffl, Walter L; Barnett, Carlton C; Cothren-Burlew, Clay; Fox, Charles; Jurkovich, Gregory J; Moore, Ernest E

    2016-02-01

    Previous studies of surgical stabilization of rib fractures (SSRF) have been limited by small sample sizes, retrospective methodology, and inclusion of only patients with flail chest. We performed a prospective, controlled evaluation of SSRF as compared with optimal medical management for severe rib fracture patterns among critically ill trauma patients. We hypothesized that SSRF improves acute outcomes. We conducted a 2-year clinical evaluation of patients with any of the following rib fracture patterns: flail chest, three or more fractures with bicortical displacement, 30% or greater hemithorax volume loss, and either severe pain or respiratory failure despite optimal medical management. In the year 2013, all patients were managed nonoperatively. In the year 2014, all patients were managed operatively. Outcomes included respiratory failure, tracheostomy, pneumonia, ventilator days, tracheostomy, length of stay, daily maximum incentive spirometer volume, narcotic requirements, and mortality. Univariate and multivariable analyses were performed. Seventy patients were included, 35 in each group. For the operative group, time from injury to surgery was 2.4 day, operative time was 1.5 hours, and the ratio of ribs fixed to ribs fractured was 0.6. The operative group had a significantly higher RibScore (4 vs. 3, respectively, p fracture patterns. Therapeutic study, level II.

  5. Improvement of diagnostic confidence for detection of multiple myeloma involvement of the ribs by a new CT software generating rib unfolded images: Comparison with 5- and 1-mm axial images

    Energy Technology Data Exchange (ETDEWEB)

    Homann, Georg; Mustafa, Deedar Farhad; Nikolaou, Konstantin; Horger, Marius [Eberhard Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Weisel, Katja [Eberhard Karls University Tuebingen, Department of Internal Medicine II, Tuebingen (Germany); Ditt, Hendrik [Healthcare Sector Imaging and Therapy Division, Siemens AG, Forchheim (Germany)

    2015-04-02

    To investigate the performance of a new CT software generating rib unfolded images for improved detection of rib osteolyses in patients with multiple myeloma. One hundred sixteen patients who underwent whole-body reduced-dose multidetector computed tomography (WBRD-MDCT) for multiple myeloma diagnosis and during follow-up were retrospectively evaluated. Nonenhanced CT scans with 5- and 1-mm slice thickness were interpreted by two readers with focus on detection of rib involvement (location, number, fracture). Image analysis of ''unfolded,'' 1-mm-based CT rib images was subsequently undertaken. We classified the number of lytic bone lesions into 0, 1, 2, <5, <10 and ≥10. For all three data sets the reading time was registered. An approximated sum of 6,727 myeloma-related rib lesions was found. On a patient-based analysis, CT (5 mm), CT (1 mm) and CT (1 mm ''unfolded rib'') yielded a sensitivity, specificity and accuracy of 79.7/94.7/87.1, 88.1/93/90.5 and 98.3/96.5/97.4, respectively. In a lesion-based analysis, the sensitivity, specificity and accuracy of the three evaluations were 69.7/87.2/70.5, 79.8/55.9/78 and 96.5/89.7/96.1. Mean reading time for 5 mm/1 mm axial images and unfolded images was 178.7/215.1/90.8 s, respectively. The generation of ''unfolded rib'' images improves detection of rib involvement in patients with multiple myeloma and significantly reduces reading time. (orig.)

  6. The Role of Minimally Invasive Plate Osteosynthesis in Rib Fixation: A Review

    Directory of Open Access Journals (Sweden)

    Michael Bemelman

    2016-02-01

    Full Text Available More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950’s, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft für osteosynthesefragen/Association for the Study of Internal Fixation. Since the introduction of plate fixation for fractures, several plates and screws have been developed, all with their own characteristics. To accomplice more fracture stability, it was thought the bigger the plate, the better. The counter side was a compromised blood supply of the bone, often resulting in bone necrosis and ultimately delayed or non-union. With the search and development of new materials and techniques for fracture fixation, less invasive procedures have become increasingly popular. This resulted in the minimally invasive plate osteosynthesis (MIPO technique for fracture fixation. With the MIPO technique, procedures could be performed with smaller incisions and thus with less soft tissue damage and a better preserved blood supply. The last 5 years rib fixation has become increasingly popular, rising evidence has becomeavailable suggesting that surgical rib fixation improves outcome of patients with a flail chest or isolated rib fractures. Many surgical approaches for rib fixation have been described in the old literature, however, most of these techniques are obscure nowadays. Currently mostly large incisions with considerable surgical insult are used to stabilize rib fractures. We think that MIPO deserves a place in the surgical treatment of rib fractures. We present the aspects of diagnosis, preoperative planning and operative techniques in regard to MIPO rib fixation.

  7. The Role of Minimally Invasive Plate Osteosynthesis in Rib Fixation: A Review

    Science.gov (United States)

    Bemelman, Michael; van Baal, Mark; Yuan, Jian Zhang; Leenen, Luke

    2016-01-01

    More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950’s, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft für osteosynthesefragen/Association for the Study of Internal Fixation. Since the introduction of plate fixation for fractures, several plates and screws have been developed, all with their own characteristics. To accomplice more fracture stability, it was thought the bigger the plate, the better. The counter side was a compromised blood supply of the bone, often resulting in bone necrosis and ultimately delayed or non-union. With the search and development of new materials and techniques for fracture fixation, less invasive procedures have become increasingly popular. This resulted in the minimally invasive plate osteosynthesis (MIPO) technique for fracture fixation. With the MIPO technique, procedures could be performed with smaller incisions and thus with less soft tissue damage and a better preserved blood supply. The last 5 years rib fixation has become increasingly popular, rising evidence has become available suggesting that surgical rib fixation improves outcome of patients with a flail chest or isolated rib fractures. Many surgical approaches for rib fixation have been described in the old literature, however, most of these techniques are obscure nowadays. Currently mostly large incisions with considerable surgical insult are used to stabilize rib fractures. We think that MIPO deserves a place in the surgical treatment of rib fractures. We present the aspects of diagnosis, preoperative planning and operative techniques in regard to MIPO rib fixation. PMID:26889439

  8. Responses of Woody Plant Functional Traits to Nitrogen Addition: A Meta-Analysis of Leaf Economics, Gas Exchange, and Hydraulic Traits.

    Science.gov (United States)

    Zhang, Hongxia; Li, Weibin; Adams, Henry D; Wang, Anzhi; Wu, Jiabing; Jin, Changjie; Guan, Dexin; Yuan, Fenghui

    2018-01-01

    Atmospheric nitrogen (N) deposition has been found to significantly affect plant growth and physiological performance in terrestrial ecosystems. Many individual studies have investigated how N addition influences plant functional traits, however these investigations have usually been limited to a single species, and thereby do not allow derivation of general patterns or underlying mechanisms. We synthesized data from 56 papers and conducted a meta-analysis to assess the general responses of 15 variables related to leaf economics, gas exchange, and hydraulic traits to N addition among 61 woody plant species, primarily from temperate and subtropical regions. Results showed that under N addition, leaf area index (+10.3%), foliar N content (+7.3%), intrinsic water-use efficiency (+3.1%) and net photosynthetic rate (+16.1%) significantly increased, while specific leaf area, stomatal conductance, and transpiration rate did not change. For plant hydraulics, N addition significantly increased vessel diameter (+7.0%), hydraulic conductance in stems/shoots (+6.7%), and water potential corresponding to 50% loss of hydraulic conductivity ( P 50 , +21.5%; i.e., P 50 became less negative), while water potential in leaves (-6.7%) decreased (became more negative). N addition had little effect on vessel density, hydraulic conductance in leaves and roots, or water potential in stems/shoots. N addition had greater effects on gymnosperms than angiosperms and ammonium nitrate fertilization had larger effects than fertilization with urea, and high levels of N addition affected more traits than low levels. Our results demonstrate that N addition has coupled effects on both carbon and water dynamics of woody plants. Increased leaf N, likely fixed in photosynthetic enzymes and pigments leads to higher photosynthesis and water use efficiency, which may increase leaf growth, as reflected in LAI results. These changes appear to have downstream effects on hydraulic function through increases

  9. Xylem hydraulic properties of roots and stems of nine Mediterranean woody species.

    Science.gov (United States)

    Martínez-Vilalta, Jordi; Prat, Ester; Oliveras, Imma; Piñol, Josep

    2002-09-01

    We studied the hydraulic architecture and water relations of nine co-occurring woody species in a Spanish evergreen oak forest over the course of a dry season. Our main objectives were to: (1) test the existence of a trade-off between hydraulic conductivity and security in the xylem, and (2) establish the safety margins at which the species operated in relation to hydraulic failure, and compare these safety margins between species and tissues (roots vs. stems). Our results showed that the relationship between specific hydraulic conductivity (K s) and resistance to cavitation followed a power function with exponent ≈-2, consistent with the existence of a trade-off between conductivity and security in the xylem, and also consistent with a linear relationship between vessel diameter and the size of inter-vessel pores. The diameter of xylem conduits, K s and vulnerability to xylem embolism were always higher in roots than in stems of the same species. Safety margins from hydraulic failure were narrower in roots than in stems. Among species, the water potential (Ψ) at which 50% of conductivity was lost due to embolism ranged between -0.9 and Cistus albidus=Ilex aquifolium>Phillyrea latifolia>Juniperus oxycedrus. Gas exchange and seasonal Ψ minima were in general correlated with resistance to xylem embolism. Hydraulic safety margins differed markedly among species, with some of them (J. oxycedrus, I. aquifolium, P. latifolia) showing a xylem overly resistant to cavitation. We hypothesize that this overly resistant xylem may be related to the shape of the relationship between K s and security we have found.

  10. Concordant preferences for actual height and facial cues to height

    OpenAIRE

    Re, Daniel Edward; Perrett, David I.

    2012-01-01

    Physical height has a well-documented effect on human mate preferences. In general, both sexes prefer opposite-sex romantic relationships in which the man is taller than the woman, while individual preferences for height are affected by a person’s own height. Research in human mate choice has demonstrated that attraction to facial characteristics, such as facial adiposity, may reflect references for body characteristics. Here, we tested preferences for facial cues to height. In general, incre...

  11. Evaluation of solitary rib lesions in CA. breast patients for development of skeletal metastasis

    International Nuclear Information System (INIS)

    Fatima, A.; Fatima, S.; Khursheed, K.; Jafri, S.; Asghar, S.

    2004-01-01

    Determination of nature of single or double rib lesion on a bone scan is important but very difficult. In case of breast carcinoma rib lesion have particular importance, as they are one of the most common sites of metastasis. On the contrary surgical trauma and radiotherapy can induce metabolic changes, which can lead to rib lesions of benign etiology. As it is known that breast carcinoma patients having skeletal metastasis have worse prognosis so it is particularly important to differentiate between malignant and benign rib lesions. In this study etiology of rib lesions detected on bone scan was analyzed retrospectively patients. Study population consisted of breast cancer patients having solitary rib lesions on baseline or follow-up bone scan were included in the study. The etiology of solitary rib involvement was established using all the clinical, radiological and biochemical data available. The clinical and serial scintigraphic data were collected and analyzed for correlation in forty-two patients. Patients were followed up for at least two subsequent bone scans. Out of total study population nine patients (21.42%) developed skeletal metastasis on follow-up. Rest of the study population is disease free till last follow-up. All these patients developed metastasis within two years of appearance of the rib lesions. Correlation between sites of initial rib lesion, uptake pattern, size of tumor, mode of primary therapy, age of involvement, interval from initial therapy, biochemical and radiological findings was done. Correlation was seen between sites of uptake, uptake pattern, mode of primary therapy and biochemical findings with subsequent outcome of the patient. It is concluded from our study that solitary rib lesion have low incidence of malignancy if other risk factors are absent. (authors)

  12. Surgical treatment of rib fracture nonunion: A single center experience.

    Science.gov (United States)

    de Jong, M B; Houwert, R M; van Heerde, S; de Steenwinkel, M; Hietbrink, F; Leenen, L P H

    2018-03-01

    In contrast to the emerging evidence on the operative treatment of flail chest, there is a paucity of literature on the surgical treatment of rib fracture nonunion. The purpose of this study was to describe our standardized approach and report the outcome (e.g. patient satisfaction, pain and complications) after surgical treatment of a rib fracture nonunion. A single centre retrospective cohort study was performed at a level 1 trauma centre. Symptomatic rib nonunion was defined as a severe persistent localized pain associated with the nonunion of one or more rib fractures on a chest CT scan at least 3 months after the initial trauma. Patients after initial operative treatment of rib fractures were excluded. Nineteen patients (11 men, 8 women), with symptomatic nonunions were included. Fourteen patients were referred from other hospitals and 8 patients received treatment from a pain medicine specialist. The mean follow-up was 36 months. No in-hospital complications were observed. In 2 patients, new fractures adjacent to the implant, without new trauma were observed. Furthermore 3 patients requested implant removal with a persistent nonunion in one patient. There was a mean follow-up of 36 months, the majority of patients (n = 13) were satisfied with the results of their surgical treatment and all patients experienced a reduction in the number of complaints. Persisting pain was a common complaint. Three patients reporting severe pain used opioid analgesics on a daily or weekly basis. Only 1 patient needed ongoing treatment by a pain medicine specialist. Surgical fixation of symptomatic rib nonunion is a safe and feasible procedure, with a low perioperative complication rate, and might be beneficial in selected symptomatic patients in the future. In our study, although the majority of patients were satisfied and the pain level subjectively decreases, complaints of persistent pain were common. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Determination of the hydraulic conductivity in column of undeformed soil by gamma rays transmission

    International Nuclear Information System (INIS)

    Moreira, Anderson C.; Cavalcante, Fabio H.M.; Portezan Filho, Otavio; Coimbra, Melayne M.; Appoloni, Carlos Roberto

    2000-01-01

    The water infiltration process in undeformed soil column and the measurement of redistribution process by gamma rays transmission in different depth allow the determination of Hydraulic Conductivity K(Θ) function, using the Sisson et al. (1980) method. A LRd (dystrophic dark red soil) soil column with 60 cm of height, 10 cm of width and 5 cm of thickness, was analyzed in laboratory, reproducing the field conditions concerning to the water infiltration and redistribution in the soil. The soil moisture content data was obtained with a radioactivity source 241 Am (100 mCi; 59,6 keV), NaI (Tl) 2x2 detector, coupled to an gamma rays spectrometric electronic chain and a measurement table that allowed the vertical displacement of the soil column. The results indicate a growing behavior for K(Θ) in relation to the depth. The collimators had 2 mm and 5 mm diameter for radioactivity source and detector respectively. (author)

  14. Action of the isolated canine diaphragm on the lower ribs at high lung volumes.

    Science.gov (United States)

    De Troyer, André; Wilson, Theodore A

    2014-10-15

    The normal diaphragm has an inspiratory action on the lower ribs, but subjects with chronic obstructive pulmonary disease commonly have an inward displacement of the lateral portions of the lower rib cage during inspiration. This paradoxical displacement, conventionally called 'Hoover's sign', has traditionally been attributed to the direct action of radially oriented diaphragmatic muscle fibres. In the present study, the inspiratory intercostal muscles in all interspaces in anaesthetized dogs were severed so that the diaphragm was the only muscle active during inspiration. The displacements of the lower ribs along the craniocaudal and laterolateral axes and the changes in pleural pressure (∆Ppl) and transdiaphragmatic pressure were measured during occluded breaths and mechanical ventilation at different lung volumes between functional residual capacity (FRC) and total lung capacity. From these data, the separate effects on rib displacement of ∆Ppl and of the force exerted by the diaphragm on the ribs were determined. Isolated spontaneous diaphragm contraction at FRC displaced the lower ribs cranially and outward, but this motion was progressively reversed into a caudal and inward motion as lung volume increased. However, although the force exerted by the diaphragm on the ribs decreased with increasing volume, it continued to displace the ribs cranially and outward. These observations suggest that Hoover's sign is usually caused by the decrease in the zone of apposition and, thus, by the dominant effect of ∆Ppl on the lower ribs, rather than an inward pull from the diaphragm. © 2014 The Authors. The Journal of Physiology © 2014 The Physiological Society.

  15. First-rib stress fracture in two adolescent swimmers: a case report.

    Science.gov (United States)

    Low, Sara; Kern, Michael; Atanda, Alfred

    2016-01-01

    First-rib stress fractures have been described in adolescent athletes in various sports, with only one prior case report of first-rib stress fractures in an adolescent female swimmer. There is a need for research on the cause, management, and prevention of these injuries as they lead to significant morbidity and critical time away from sport for these aspiring athletes. We aimed to describe first-rib stress fractures as a potential cause for non-specific atraumatic chronic shoulder pain in adolescent swimmers and to discuss the different presentations, unique risk factors, treatment, and potential injury prevention strategies of such fractures. We discussed two such cases which were successfully treated with activity modification with restriction of all overhead activity, gradually progressive physical therapy and a return to swimming protocol. First-rib stress fractures can vary in presentation and should be in the differential diagnosis in adolescent swimmers with chronic shoulder pain. These injuries can be successfully managed with rest from overhead activities and physical therapy. Gradual return to competitive swimming can be achieved even with non-union of a first-rib stress fracture. Emphasis on balanced strength training in different muscle groups and proper swimming technique is essential to prevent these injuries.

  16. Cutoff-mesa isolated rib optical waveguide for III-V heterostructure photonic integrated circuits

    Science.gov (United States)

    Vawter, G.A.; Smith, R.E.

    1998-04-28

    A cutoff mesa rib waveguide provides single-mode performance regardless of any deep etches that might be used for electrical isolation between integrated electrooptic devices. Utilizing a principle of a cutoff slab waveguide with an asymmetrical refractive index profile, single mode operation is achievable with a wide range of rib widths and does not require demanding etch depth tolerances. This new waveguide design eliminates reflection effects, or self-interference, commonly seen when conventional rib waveguides are combined with deep isolation etches and thereby reduces high order mode propagation and crosstalk compared to the conventional rib waveguides. 7 figs.

  17. Phrenic Arterial Injury Presenting as Delayed Hemothorax Complicating Simple Rib Fracture.

    Science.gov (United States)

    Ahn, Hong Joon; Lee, Jun Wan; Kim, Kun Dong; You, In Sool

    2016-04-01

    Delayed hemothorax after blunt torso injury is rare, but might be associated with significant morbidity and mortality. We present a case of delayed hemothorax bleeding from phrenic artery injury in a 24-year-old woman. The patient suffered from multiple rib fractures on the right side, a right hemopneumothorax, thoracic vertebral injury and a pelvic bone fracture after a fall from a fourth floor window. Delayed hemothorax associated with phrenic artery bleeding, caused by a stab injury from a fractured rib segment, was treated successfully by a minimally invasive thoracoscopic surgery. Here, we have shown that fracture of a lower rib or ribs might be accompanied by delayed massive hemothorax that can be rapidly identified and promptly managed by thoracoscopic means.

  18. Rib fractures after reirradiation plus hyperthermia for recurrent breast cancer. Predictive factors

    International Nuclear Information System (INIS)

    Oldenborg, Sabine; Valk, Christel; Os, Rob van; Voerde Sive Voerding, Paul zum; Crezee, Hans; Tienhoven, Geertjan van; Rasch, Coen; Oei, Bing; Venselaar, Jack; Randen, Adrienne van

    2016-01-01

    Combining reirradiation (reRT) and hyperthermia (HT) has shown high therapeutic value for patients with locoregional recurrent breast cancer (LR). However, additional toxicity of reirradiation (e.g., rib fractures) may occur. The aim of this study is to determine the impact of potential risk factors on the occurrence of rib fractures. From 1982-2005, 234 patients were treated with adjuvant reRT + HT after surgery for LR. ReRT consisted typically of 8 fractions of 4 Gy twice a week, or 12 fractions of 3 Gy four times a week. A total of 118 patients were irradiated with abutted photon and electron fields. In all, 60 patients were irradiated using either one or alternating combinations of abutted AP electron fields. Hyperthermia was given once or twice a week. The 5-year infield local control (LC) rate was 70 %. Rib fractures were detected in 16 of 234 patients (actuarial risk: 7 % at 5 years). All rib fractures occurred in patients treated with a combination of photon and abutted electron fields (p = 0.000); in 15 of 16 patients fractures were located in the abutment regions. The other significant predictive factors for rib fractures were a higher fraction dose (p = 0.040), large RT fields, and treatment before the year 2000. ReRT + HT results in long-term LC. The majority of rib fractures were located in the photon/electron abutment area, emphasizing the disadvantage of field overlap. Large abutted photon/electron fields combined with 4 Gy fractions increase the number of rib fractures in this study group. However, as these factors were highly correlated no relative importance of the individual factors could be estimated. Increasing the number of HT sessions a week does not increase the risk of rib fractures. (orig.) [de

  19. Stress fractures of the rib arising from the manufactory assembly line

    International Nuclear Information System (INIS)

    Arima, Toru; Iwasaki, Masayuki

    2007-01-01

    We investigated stress injuries of the rib arising from the assembly line. The patients, all males, were 20 in number and divided into two groups; those with stress fracture (n=13) and those with ''pre-fracture'' (n=7). The former group with the average age of 37 years was involved by a single fracture in 10 patients and multiple fractures in 3, ranging from 5th to 8th ribs, with the affected side on the right in 9 and the left in 4. All 13 fractures occurred in the posterior half of the rib, in which 5 were located in its lateral portion, 5 in the middle, and 3 in the posterior. The latter group with the average age of 32 years were involved on the right side in 4 and the left in 3. The working pattern causing rib injuries was either repeated raising of the upper extremity or forward pushing of the shoulder girdle. The symptom was back pain, and aggravated especially in elevation of the arm, deep breathing and sneezing. Local tenderness over the fracture site was noted in all cases. X-ray findings at initial examination revealed fractures in most cases and 3D-CT was employed in 9 questionable cases to assess fracture conditions. In the ''pre-fracture'' group, although the fracture was not recognized on X-ray, the diagnosis was made as an impending fracture based on the localized tenderness on the rib. As to treatment, bust band fixation and work load reduction were performed. Stress fractures of the rib have been occasionally reported in sports medicine, but not so much in industrial medicine. This specific injury has been treated in literature as muscle strain because of the absence of apparent trauma. It is important to recognize the underlying pathology to make the correct diagnosis. In the early stage of rib fractures, 3D-CT was more useful than X-ray in making diagnosis and assessing the bony union. As to the pathomechanism of this condition, it was postulated that repeated raising or forward pushing of the arm applying excessive traction to the origin of the

  20. Retrospective evaluation and dating of non-accidental rib fractures in infants

    International Nuclear Information System (INIS)

    Sanchez, T.R.; Nguyen, H.; Palacios, W.; Doherty, M.; Coulter, K.

    2013-01-01

    Aim: To describe the sequential appearance of healing rib fractures on initial and follow-up radiographs using published guidelines in approximating the age of rib fractures in infants with the aim of establishing a more objective method of dating rib fractures by measuring the thickness of the callous formation. Materials and methods: This was a retrospective analysis of initial and follow-up digital skeletal surveys of infants less than 12 months of age performed between January 2008 and January 2012 at the University of California Davis Children's Hospital. Six radiological features of rib fractures evaluating the appearance of the callous formation (C stage) and fracture line (F stage) were assessed. Patients with osteogenesis imperfecta, known vitamin D deficiency, and skeletal or metabolic dysplasia were not included in the study. Thereafter, callous thickness was measured and recorded for each stage. Results: Sixteen infants (age range 1–11 months, seven males and nine females) with 23 rib fractures were analysed. The thickness of the callous formation follows a predictable pattern advancing one stage after a 2-week follow-up with progressive callous thickening starting from stage 2, peaks at around stage 4, and then tapers and remodels until it almost disappears when the fracture is healed at stage 6. Conclusion: It appears that rib fractures in infants follow a predictable pattern of healing. Measuring the thickness of the callous formation is a more objective way of guiding the radiologist in estimating the age of the fracture

  1. Frequency of intrathoracic injuries in children younger than 3 years with rib fractures

    International Nuclear Information System (INIS)

    Darling, Stephen E.; Done, Stephen L.; Friedman, Seth D.; Feldman, Kenneth W.

    2014-01-01

    Research documents that among children admitted to trauma intensive care units the number of rib fractures sustained indicates the child's likelihood of having and severity of intrathoracic injury. This has been misused in court to argue that children with multiple rib fractures who lack intrathoracic injury have abnormal bone fragility rather than inflicted injury. To determine frequency of intrathoracic injuries in children younger than 3 years with rib fractures in cases of child abuse and accidental trauma. We conducted a retrospective review of rib fractures caused by documented abuse or accidents from 2003 to 2010 in children treated at Seattle Children's Hospital and Harborview Medical Center. A senior pediatric radiologist and radiology fellow independently reviewed the imaging. Children with bone demineralization were excluded. Descriptive and simple comparative statistics were used. Seventy-two percent (47/65) of infants and toddlers with rib fractures were abused. Abused children had more rib fractures than accidentally injured children (5.55 vs. 3.11, P = 0.012). However intrathoracic injuries as a whole (55.6% vs. 12.8%, P < 0.001) and individual types of intrathoracic injuries were more common with accidents. Rates of other thoracic cage injuries did not differ substantially (27.8% accidents vs. 12.8% abuse, P = 0.064). Intracranial and intra-abdominal injuries and skull fractures were equally frequent, but other extrathoracic fractures were more common with abuse (70.2% vs. 16.7%, P < 0.001). Abused infants and toddlers have fewer intrathoracic injuries but more rib fractures than accidentally injured peers. This likely reflects different injury mechanics. Lack of intrathoracic injuries in abused children with rib fractures does not imply bone fragility. (orig.)

  2. Frequency of intrathoracic injuries in children younger than 3 years with rib fractures

    Energy Technology Data Exchange (ETDEWEB)

    Darling, Stephen E. [Kapiolani Children' s Hospital, The Department of Radiology, Honolulu, HI (United States); Done, Stephen L.; Friedman, Seth D. [Seattle Children' s Hospital, The Department' s of Radiology, Seattle, WA (United States); University of Washington School of Medicine, Seattle, WA (United States); Feldman, Kenneth W. [Seattle Children' s Hospital, Pediatrics, General Pediatrics Division, Seattle, WA (United States); Seattle Children' s Protection Program, Children' s Protection Program, M/S M2-10, Seattle, WA (United States); University of Washington School of Medicine, Seattle, WA (United States)

    2014-10-15

    Research documents that among children admitted to trauma intensive care units the number of rib fractures sustained indicates the child's likelihood of having and severity of intrathoracic injury. This has been misused in court to argue that children with multiple rib fractures who lack intrathoracic injury have abnormal bone fragility rather than inflicted injury. To determine frequency of intrathoracic injuries in children younger than 3 years with rib fractures in cases of child abuse and accidental trauma. We conducted a retrospective review of rib fractures caused by documented abuse or accidents from 2003 to 2010 in children treated at Seattle Children's Hospital and Harborview Medical Center. A senior pediatric radiologist and radiology fellow independently reviewed the imaging. Children with bone demineralization were excluded. Descriptive and simple comparative statistics were used. Seventy-two percent (47/65) of infants and toddlers with rib fractures were abused. Abused children had more rib fractures than accidentally injured children (5.55 vs. 3.11, P = 0.012). However intrathoracic injuries as a whole (55.6% vs. 12.8%, P < 0.001) and individual types of intrathoracic injuries were more common with accidents. Rates of other thoracic cage injuries did not differ substantially (27.8% accidents vs. 12.8% abuse, P = 0.064). Intracranial and intra-abdominal injuries and skull fractures were equally frequent, but other extrathoracic fractures were more common with abuse (70.2% vs. 16.7%, P < 0.001). Abused infants and toddlers have fewer intrathoracic injuries but more rib fractures than accidentally injured peers. This likely reflects different injury mechanics. Lack of intrathoracic injuries in abused children with rib fractures does not imply bone fragility. (orig.)

  3. The influence of hydraulic conditions on coagulation process effectiveness

    Directory of Open Access Journals (Sweden)

    Sambor Aleksandra

    2017-01-01

    Full Text Available This paper presents the impact that small changes in the hydraulic installation between the flocculation chamber and the sedimentation tanks have on coagulation process effectiveness. This study has shown significant improvements in the parameters of the treated water. The research was conducted in two treatment systems: reference and test, in order to compare the changes that were introduced in the time period between January and May 2016. The hydraulic conditions between the flocculation chamber and the sedimentation tank were changed in the test system, leaving the reference system unchanged for comparative purposes. The height-wise positioning of the sedimentation tank relative to the flocculation chamber resulted in a formation of a cascade at the flocculation chamber drain at a height of 0.60m. Air was therefore introduced into the water, forming an air-water mixture, which disturbed the flow between the devices. It was found that floc transported by the pipeline was broken down, which hampered sedimentation in the sedimentation tank. This was confirmed by the analysis of chosen parameters from treated water. After changes in the hydraulic system, changes in water turbidity were noticed, indicating an increase in post-coagulation suspension separation effectiveness. Consequently, an increase in organic carbon removal was found relative to the reference system. This change influenced changes in UV254 absorbance to a much lesser extent.

  4. The influence of hydraulic conditions on coagulation process effectiveness

    Science.gov (United States)

    Sambor, Aleksandra; Ferenc, Zbigniew

    2017-11-01

    This paper presents the impact that small changes in the hydraulic installation between the flocculation chamber and the sedimentation tanks have on coagulation process effectiveness. This study has shown significant improvements in the parameters of the treated water. The research was conducted in two treatment systems: reference and test, in order to compare the changes that were introduced in the time period between January and May 2016. The hydraulic conditions between the flocculation chamber and the sedimentation tank were changed in the test system, leaving the reference system unchanged for comparative purposes. The height-wise positioning of the sedimentation tank relative to the flocculation chamber resulted in a formation of a cascade at the flocculation chamber drain at a height of 0.60m. Air was therefore introduced into the water, forming an air-water mixture, which disturbed the flow between the devices. It was found that floc transported by the pipeline was broken down, which hampered sedimentation in the sedimentation tank. This was confirmed by the analysis of chosen parameters from treated water. After changes in the hydraulic system, changes in water turbidity were noticed, indicating an increase in post-coagulation suspension separation effectiveness. Consequently, an increase in organic carbon removal was found relative to the reference system. This change influenced changes in UV254 absorbance to a much lesser extent.

  5. Sex determination based on a thoracic vertebra and ribs evaluation using clinical chest radiography.

    Science.gov (United States)

    Tsubaki, Shun; Morishita, Junji; Usumoto, Yosuke; Sakaguchi, Kyoko; Matsunobu, Yusuke; Kawazoe, Yusuke; Okumura, Miki; Ikeda, Noriaki

    2017-07-01

    Our aim was to investigate whether sex can be determined from a combination of geometric features obtained from the 10th thoracic vertebra, 6th rib, and 7th rib. Six hundred chest radiographs (300 males and 300 females) were randomly selected to include patients of six age groups (20s, 30s, 40s, 50s, 60s, and 70s). Each group included 100 images (50 males and 50 females). A total of 14 features, including 7 lengths, 5 indices for the vertebra, and 2 types of widths for ribs, were utilized and analyzed for sex determination. Dominant features contributing to sex determination were selected by stepwise discriminant analysis after checking the variance inflation factors for multicollinearity. The accuracy of sex determination using a combination of the vertebra and ribs was evaluated from the selected features by the stepwise discriminant analysis. The accuracies in each age group were also evaluated in this study. The accuracy of sex determination based on a combination of features of the vertebra and ribs was 88.8% (533/600). This performance was superior to that of the vertebra or ribs only. Moreover, sex determination of subjects in their 20s demonstrated the highest accuracy (96.0%, 96/100). The features selected in the stepwise discriminant analysis included some features in both the vertebra and ribs. These results indicate the usefulness of combined information obtained from the vertebra and ribs for sex determination. We conclude that a combination of geometric characteristics obtained from the vertebra and ribs could be useful for determining sex. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Ultrasonography as a better diagnostic efficiency in rib fracture

    OpenAIRE

    UZUN, Metin; BEKSAÇ, Burak; KARATAŞ, Adnan; KÜÇÜKDURMAZ, Fatih; KIRCALI, Bahar ANAYURDU; TETİK, Cihangir

    2013-01-01

    In this study, our aim was to demonstrate the need of use of ultrasonography in rib fractures in order not to face medicolegal problems. One hundred patients admitted to our emergency service with mild to moderate blunt thorax trauma were included in our study prospectively. The inclusion criteria were pain upon palpation of ribs, deep inspiration, coughing but no any other pathologies like a pneumothorax, hemothorax. All patients are evaluated with ultrasonography (USG) and direct X-rays. X-...

  7. Elevational trends in hydraulic efficiency and safety of Pinus cembra roots.

    Science.gov (United States)

    Losso, Adriano; Nardini, Andrea; Nolf, Markus; Mayr, Stefan

    2016-04-01

    In alpine regions, elevational gradients in environmental parameters are reflected by structural and functional changes in plant traits. Elevational changes in plant water relations have also been demonstrated, but comparable information on root hydraulics is generally lacking. We analyzed the hydraulic efficiency (specific hydraulic conductivity k s, entire root system conductance K R) and vulnerability to drought-induced embolism (water potential at 50 % loss of conductivity Ψ 50) of the roots of Pinus cembra trees growing along an elevational transect of 600 m. Hydraulic parameters of the roots were compared with those of the stem and related to anatomical traits {mean conduit diameter (d), wall reinforcement [(t/b)(2)]}. We hypothesized that temperature-related restrictions in root function would cause a progressive limitation of hydraulic efficiency and safety with increasing elevation. We found that both root k s and K R decreased from low (1600 m a.s.l.: k s 5.6 ± 0.7 kg m(-1) s(-1) MPa(-1), K R 0.049 ± 0.005 kg m(-2) s (-1) MPa(-1)) to high elevation (2100 m a.s.l.: k s 4.2 ± 0.6 kg m(-1) s(-1) MPa(-1), K R 0.035 ± 0.006 kg m(-2) s(-1) MPa(-1)), with small trees showing higher K R than large trees. k s was higher in roots than in stems (0.5 ± 0.05 kg m(-1)s(-1)MPa(-1)). Ψ 50 values were similar across elevations and overall less negative in roots (Ψ 50 -3.6 ± 0.1 MPa) than in stems (Ψ 50 -3.9 ± 0.1 MPa). In roots, large-diameter tracheids were lacking at high elevation and (t/b)(2) increased, while d did not change. The elevational decrease in root hydraulic efficiency reflects a limitation in timberline tree hydraulics. In contrast, hydraulic safety was similar across elevations, indicating that avoidance of hydraulic failure is important for timberline trees. As hydraulic patterns can only partly be explained by the anatomical parameters studied, limitations and/or adaptations at the pit level are likely.

  8. Sonography of occult rib and costal cartilage fractures: a case series.

    Science.gov (United States)

    Mattox, Ross; Reckelhoff, Kenneth E; Welk, Aaron B; Kettner, Norman W

    2014-06-01

    The purpose of this case series is to describe the use of diagnostic ultrasound (US) in the detection of occult rib and costal cartilage fractures presenting as chest wall pain to a chiropractic clinic. Three patients presented with chest wall pain and tenderness. Two of the patients presented with acute chest wall injury and 1 carried a previous diagnosis of rib fracture after trivial trauma 2 months earlier. Diagnostic US was selected as a non-ionizing imaging tool for these patients after negative digital radiography studies. All fractures were considered isolated as there was no associated injury, such as pneumothorax. Both of the acute cases were followed up to complete healing (evidence of osseous union) using US. All patients eventually achieved pain-free status. In these cases, US was more sensitive than radiography for diagnosing these cases of acute rib and costal cartilage fractures. Early recognition of rib injury could avoid potential complications from local manipulative therapy.

  9. A Novel Biodegradable Polycaprolactone Fixator for Osteosynthesis Surgery of Rib Fracture: In Vitro and in Vivo Study

    Directory of Open Access Journals (Sweden)

    Yi-Hsun Yu

    2015-11-01

    Full Text Available Osteosynthesis surgery for rib fractures is controversial and challenging. This study developed a noval poly(ε-caprolactone (PCL-based biodegradable “cable-tie” fixator for osteosynthesis surgery for rib fractures. A biodegradable fixator specifically for fractured ribs was designed and fabricated by a micro-injection molding machine in our laboratory. The fixator has three belts that could be passed through matching holes individually. The locking mechanism allows the belt movement to move in only one direction. To examine the in vitro biomechanical performance, ribs 3–7 from four fresh New Zealand rabbits were employed. The load to failure and stress-strain curve was compared in the three-point bending test among native ribs, titanium plate-fixed ribs, and PCL fixator-fixed ribs. In the in vivo animal study, the sixth ribs of New Zealand rabbits were osteotomized and osteosynthesis surgery was performed using the PCL fixator. Outcomes were assessed by monthly X-ray examinations, a final micro-computed tomography (CT scan, and histological analysis. The experimental results suggested that the ribs fixed with the PCL fixator were significantly less stiff than those fixed with titanium plates (p < 0.05. All ribs fixed with the PCL fixators exhibited union. The bridging callus was confirmed by gross, radiographic micro-three-dimensional (3D CT, and histological examinations. In addition, there was no significant inflammatory response of the osteotomized ribs or the PCL-rib interface during application. The novel PCL fixator developed in this work achieves satisfactory results in osteosynthesis surgery for rib fractures, and may provide potential applications in other orthopedic surgeries.

  10. Flexural performance of steel fiber reinforced concrete (SFRC) ribbed slab with various topping thicknesses

    Science.gov (United States)

    Rahman, Fadhillah Abdul; Bakar, Afidah Abu; Hashim, Mohd Hisbany Mohd; Ahmad, Hazrina

    2017-11-01

    Ribbed slab provides lighter slab than an equivalent solid slab which helps in reducing the weight with its voids. However, in order to overcome the drawbacks in the construction process, the application of steel fibre reinforcement concrete (SFRC) is seen as an alternative material to be used in the slab. This study is performed to investigate the behaviour of SFRC as the main material in ribbed slab, omitting the conventional reinforcements, under four-point bending test. Three equivalent samples of ribbed slabs were prepared for this study with variations in the topping thickness of 100, 75 and 50 mm. The flexural strength of ribbed slab with 100 mm topping shows similar loading carrying capacity with the 75mm topping while 50 mm gave the lowest ultimate loading. First cracks for all slabs occurred at the topping. The cracks began from the external ribs and propagates toward the internal rib. Incorporation of steel fibres help in giving a longer deflection softening than a sudden brittle failure, thus proves its ability to increase energy absorption capacity and improving cracking behaviour.

  11. Rib fractures and death from deletion of osteoblast βcatenin in adult mice is rescued by corticosteroids.

    Science.gov (United States)

    Duan, JinZhu; Lee, Yueh; Jania, Corey; Gong, Jucheng; Rojas, Mauricio; Burk, Laurel; Willis, Monte; Homeister, Jonathon; Tilley, Stephen; Rubin, Janet; Deb, Arjun

    2013-01-01

    Ribs are primarily made of cortical bone and are necessary for chest expansion and ventilation. Rib fractures represent the most common type of non-traumatic fractures in the elderly yet few studies have focused on the biology of rib fragility. Here, we show that deletion of βcatenin in Col1a2 expressing osteoblasts of adult mice leads to aggressive osteoclastogenesis with increased serum levels of the osteoclastogenic cytokine RANKL, extensive rib resorption, multiple spontaneous rib fractures and chest wall deformities. Within days of osteoblast specific βcatenin deletion, animals die from respiratory failure with a vanishing rib cage that is unable to sustain ventilation. Increased bone resorption is also observed in the vertebrae and femur. Treatment with the bisphosphonate pamidronate delayed but did not prevent death or associated rib fractures. In contrast, administration of the glucocorticoid dexamethasone decreased serum RANKL and slowed osteoclastogenesis. Dexamethasone preserved rib structure, prevented respiratory compromise and strikingly increased survival. Our findings provide a novel model of accelerated osteoclastogenesis, where deletion of osteoblast βcatenin in adults leads to rapid development of destructive rib fractures. We demonstrate the role of βcatenin dependent mechanisms in rib fractures and suggest that glucocorticoids, by suppressing RANKL, may have a role in treating bone loss due to aggressive osteoclastogenesis.

  12. Diameter modulation of vertically aligned single-walled carbon nanotubes.

    Science.gov (United States)

    Xiang, Rong; Einarsson, Erik; Murakami, Yoichi; Shiomi, Junichiro; Chiashi, Shohei; Tang, Zikang; Maruyama, Shigeo

    2012-08-28

    We demonstrate wide-range diameter modulation of vertically aligned single-walled carbon nanotubes (SWNTs) using a wet chemistry prepared catalyst. In order to ensure compatibility to electronic applications, the current minimum mean diameter of 2 nm for vertically aligned SWNTs is challenged. The mean diameter is decreased to about 1.4 nm by reducing Co catalyst concentrations to 1/100 or by increasing Mo catalyst concentrations by five times. We also propose a novel spectral analysis method that allows one to distinguish absorbance contributions from the upper, middle, and lower parts of a nanotube array. We use this method to quantitatively characterize the slight diameter change observed along the array height. On the basis of further investigation of the array and catalyst particles, we conclude that catalyst aggregation-rather than Ostwald ripening-dominates the growth of metal particles.

  13. Heat transfer tests of ribbed surfaces for gas-cooled reactors

    International Nuclear Information System (INIS)

    Klepper, O.H.

    1975-07-01

    The performance of gas-cooled reactors is often limited by the heat transfer in the reactor core. Means for modifying core heat transfer surfaces to improve their performance were investigated. The 0.3-in.-OD stainless steel clad heater rods were photo-etched to produce external ribs 0.006 in. high and 0.12 in. wide with a pitch of 0.072 in. Helical ribs with a helix angle of 37 0 (to promote interchannel flow mixing in a multirod array) were provided on one surface. For comparison purposes, a transversely ribbed surface and a smooth rod were also studied. The test surfaces were 49 in. long with a 24-in. heated region, concentrically arranged inside a smooth 0.602-in.-ID stainless steel tube. Nitrogen gas at pressures up to 400 psig was used as the coolant; the linear heat rating ranged to 6.8 kW/ft at surface temperatures up to 1400 0 F; T/sub w/T/sub b/ varied from 1.2 to 2.4 at Re values up to 450,000. Annulus results were recalculated for rod geometry using two different transformations. Good agreement was observed with applicable literature values. The effectiveness of the surfaces was assessed as the ratio E of the heat transfer coefficients of the roughened rods to that of a smooth rod at the same pumping power. The effectiveness of the spiral ribs ranged from 1.3 to 1.4, and from 1.2 to 1.4 for the transverse ribs, spanning Re values from 60,000 to 400,000. These data include variations introduced by alternate transformation methods that were used to make annulus test results applicable to rod geometry. The surfaces investigated in these tests were considered for fast gas-cooled reactors; however, the range of parameters studied also applies to heat transfer from ribbed rod-type fuel elements in thermal gas-cooled reactors. (U.S.)

  14. Search for the maximum efficiency of a ribbed-surfaces device, providing a tight seal

    International Nuclear Information System (INIS)

    Boutin, Jeanne.

    1977-04-01

    The purpose of this experiment was to determine the geometrical characteristics of ribbed surfaces used to equip devices in translation or slow rotation motion and having to form an acceptable seal between slightly viscous fluids. It systematically studies the pressure loss coefficient lambda in function of the different parameters setting the form of ribs and their relative position on the opposite sides. It shows that the passages with two ribbed surfaces lead to highly better results than those with only one, the maximum value of lambda, equal to 0.5, being obtained with the ratios: pitch/clearance = 5, depth of groove/clearance = 1,2, and with their teeth face to face on the two opposite ribbed surfaces. With certain shapes, alternate position of ribs can lead to the maximum of lambda yet lower than 0.5 [fr

  15. Pulmonary embolism developing after rib fracture

    Directory of Open Access Journals (Sweden)

    Manabu Nemoto

    2014-04-01

    Full Text Available In this letter, we wanted to show that acute pulmonary embolism may be observed as a complication in patients with traumatic rib fracture and to emphasize on the importance the early diagnosis examinations in suspicious cases.

  16. Focusing of high intensity ultrasound through the rib cage using a therapeutic random phased array

    Science.gov (United States)

    Bobkova, Svetlana; Gavrilov, Leonid; Khokhlova, Vera; Shaw, Adam; Hand, Jeffrey; #, ||

    2010-01-01

    A method for focusing high intensity ultrasound through a rib cage that aims to minimize heating of the ribs whilst maintaining high intensities at the focus (or foci) is proposed and tested theoretically and experimentally. Two approaches, one based on geometric acoustics and the other accounting for diffraction effects associated with propagation through the rib cage, are investigated theoretically for idealized source conditions. It is shown that for an idealized radiator the diffraction approach provides a 23% gain in peak intensity and results in significantly less power losses on the ribs (1% versus 7.5% of the irradiated power) compared with the geometric one. A 2D 1-MHz phased array with 254 randomly distributed elements, tissue mimicking phantoms, and samples of porcine rib cages are used in experiments; the geometric approach is used to configure how the array is driven. Intensity distributions are measured in the plane of the ribs and in the focal plane using an infra-red camera. Theoretical and experimental results show that it is possible to provide adequate focusing through the ribs without overheating them for a single focus and several foci, including steering at ± 10–15 mm off and ± 20 mm along the array axis. Focus splitting due to the periodic spatial structure of ribs is demonstrated both in simulations and experiments; the parameters of splitting are quantified. The ability to produce thermal lesions with a split focal pattern in ex vivo porcine tissue placed beyond the rib phantom is also demonstrated. The results suggest that the method is potentially useful for clinical applications of HIFU for which the rib cage lies between the transducer(s) and the targeted tissue. PMID:20510186

  17. Shanidar 3 Neandertal rib puncture wound and paleolithic weaponry.

    Science.gov (United States)

    Churchill, Steven E; Franciscus, Robert G; McKean-Peraza, Hilary A; Daniel, Julie A; Warren, Brittany R

    2009-08-01

    Since its discovery and initial description in the 1960s, the penetrating lesion to the left ninth rib of the Shanidar 3 Neandertal has been a focus for discussion about interpersonal violence and weapon technology in the Middle Paleolithic. Recent experimental studies using lithic points on animal targets suggest that aspects of weapon system dynamics can be inferred from the form of the bony lesions they produce. Thus, to better understand the circumstances surrounding the traumatic injury suffered by Shanidar 3, we conducted controlled stabbing experiments with replicas of Mousterian and Levallois points directed against the thoraces of pig carcasses. Stabs were conducted under both high and low kinetic energy conditions, in an effort to replicate the usual impact forces associated with thrusting spear vs. long-range projectile weapon systems, respectively. Analysis of the lesions produced in the pig ribs, along with examination of goat ribs subjected primarily to high kinetic energy stabs from an independent experiment, revealed consistent differences in damage patterns between the two conditions. In the case of Shanidar 3, the lack of major involvement of more than one rib, the lack of fracturing of the affected and adjacent ribs, and the lack of bony defects associated with the lesion (such as wastage, hinging, and radiating fracture lines) suggests that the weapon that wounded him was carrying relatively low kinetic energy. While accidental injury or attack with a thrusting spear or knife cannot absolutely be ruled out, the position, angulation, and morphology of the lesion is most consistent with injury by a low-mass, low-kinetic energy projectile weapon. Given the potential temporal overlap of Shanidar 3 with early modern humans in western Asia, and the possibility that the latter were armed with projectile weapon systems, this case carries more than simple paleoforensic interest.

  18. Isolated Cervical Rib Fracture: A Rare Etiology of Thoracic Outlet Syndrome

    Directory of Open Access Journals (Sweden)

    Rayees Ahmad Dar

    2011-01-01

    Full Text Available Isolated fracture of a cervical rib is a very rare entity and usually presents as a painless swelling or as thoracic outlet syndrome. We describe a case of a 45-year-old woman with history of fall two months back. She presented with symptoms of neurogenic thoracic outlet syndrome for one month. Isolated left cervical rib fracture was documented on X-ray cervical spine. Her fractured cervical rib was resected through a supraclavicular approach, and symptoms resolved completely in the postoperative period.

  19. Surgical Stabilization of Rib Fractures in a 6-Year-Old Child After Blunt Trauma.

    Science.gov (United States)

    Abdelsattar, Zaid M; Ishitani, Michael B; Kim, Brian D

    2017-12-01

    When identified, rib fractures in children are associated with high-energy trauma, nonaccidental trauma, or both. Traditionally, the optimal management of rib fractures in children is supportive care. In this case report, we present a 6-year-old boy who underwent surgical rib fixation for multiple displaced and comminuted rib fractures after being stepped on by a horse. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. The Influence of Hydraulic Fracturing on Carbon Storage Performance

    Science.gov (United States)

    Fu, Pengcheng; Settgast, Randolph R.; Hao, Yue; Morris, Joseph P.; Ryerson, Frederick J.

    2017-12-01

    Conventional principles of the design and operation of geologic carbon storage (GCS) require injecting CO2 below the caprock fracturing pressure to ensure the integrity of the storage complex. In nonideal storage reservoirs with relatively low permeability, pressure buildup can lead to hydraulic fracturing of the reservoir and caprock. While the GCS community has generally viewed hydraulic fractures as a key risk to storage integrity, a carefully designed stimulation treatment under appropriate geologic conditions could provide improved injectivity while maintaining overall seal integrity. A vertically contained hydraulic fracture, either in the reservoir rock or extending a limited height into the caprock, provides an effective means to access reservoir volume far from the injection well. Employing a fully coupled numerical model of hydraulic fracturing, solid deformation, and matrix fluid flow, we study the enabling conditions, processes, and mechanisms of hydraulic fracturing during CO2 injection. A hydraulic fracture's pressure-limiting behavior dictates that the near-well fluid pressure is only slightly higher than the fracturing pressure of the rock and is insensitive to injection rate and mechanical properties of the formation. Although a fracture contained solely within the reservoir rock with no caprock penetration, would be an ideal scenario, poroelastic principles dictate that sustaining such a fracture could lead to continuously increasing pressure until the caprock fractures. We also investigate the propagation pattern and injection pressure responses of a hydraulic fracture propagating in a caprock subjected to heterogeneous in situ stress. The results have important implications for the use of hydraulic fracturing as a tool for managing storage performance.

  1. Upper extremity and rib stress fractures in a child

    International Nuclear Information System (INIS)

    Moon, B.S.; Price, C.T.; Campbell, J.B.

    1998-01-01

    Stress fractures in children are rare compared with the incidence in [ults. This report describes an 11-year-old girl with stress fractures of the acromion, clavicle, and first rib on the left and contralateral fractures of the first and second ribs. It was eventually discovered that these fractures were caused by a nervous tic consisting of repetitive, vigorous shrugging and translation of the shoulders. (orig.)

  2. Delayed chest wall hematoma caused by progressive displacement of rib fractures after blunt trauma

    Directory of Open Access Journals (Sweden)

    Nobuhiro Sato

    2016-06-01

    Full Text Available Rib fracture is a common injury resulting from blunt thoracic trauma. Although hemothorax and pneumothorax are known delayed complications of rib fracture, delayed chest wall hematoma has rarely been reported. We discuss the case of an 81-year-old woman who was not undergoing antiplatelet or anticoagulant therapy who presented to our emergency department after a traffic injury. This patient had a nondisplaced rib fracture that went undetected on the initial computed tomography scan; the development of progressive displacement led to hemorrhagic shock due to delayed chest wall hematoma. The chest wall hematoma was effectively diagnosed and treated via contrast-enhanced computed tomography and angiographic embolization. This case highlights the possibility of this potential delayed complication from a common injury such as a rib fracture. Keywords: Angiography, Chest wall, Delayed complication, Rib fracture, Thoracic injury

  3. [Surgical fixation of rib fractures with clips and titanium bars (STRATOS System). Preliminary experience].

    Science.gov (United States)

    Moreno De La Santa Barajas, Pablo; Polo Otero, María Dolores; Delgado Sánchez-Gracián, Carlos; Lozano Gómez, Manuel; Toscano Novella, Alberto; Calatayud Moscoso Del Prado, Julia; Leal Ruiloba, Sonsoles; Choren Durán, Maria L

    2010-09-01

    Rib fractures are very common in closed chest injuries. The majority of these patients suffer significant pain with movement and cough. The purpose of this study is to assess the usefulness of titanium rib bars and clips in stabilising rib fractures. Twenty-two patients with rib fractures were treated with open reduction and internal fixation between 2008 and 2009. Indications for treatment were defined as; 1) Patients with unstable chest (13 patients), 2) Patients with pain or instability due to rib fractures (6 patients), and 3) Significant traumatic deformities of the chest wall (3 patients). Age, traumatic mechanism, chest and associated injuries, surgical data, complications and follow-up were prospectively analysed. The surgical technique is described. The majority of patients were extubated immediately after surgery. All patients with pain or instability showed a subjective improvement or disappearance of pain after the surgery. Four patients had a wound infection which had to be drained. After 3 months, 55% of the patients had returned to work or normal life. The results in each group are described. Open reduction with internal fixation of rib fractures is a good alternative. The use of titanium rib bars and clips give good clinical results, are easy to apply and have few complications. Copyright © 2010 AEC. Published by Elsevier Espana. All rights reserved.

  4. Does Cardiopulmonary Resuscitation Cause Rib Fractures in Children? A Systematic Review

    Science.gov (United States)

    Maguire, Sabine; Mann, Mala; John, Nia; Ellaway, Bev; Sibert, Jo R.; Kemp, Alison M.

    2006-01-01

    Background: There is a diagnostic dilemma when a child presents with rib fractures after cardiopulmonary resuscitation (CPR) where child abuse is suspected as the cause of collapse. We have performed a systematic review to establish the evidence base for the following questions: (i) Does cardiopulmonary resuscitation cause rib fractures in…

  5. Methods of counting ribs on chest CT: the modified sternomanubrial approach

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Kyung Sik; Kim, Sung Jin; Jeon, Min Hee; Lee, Seung Young; Bae, Il Hun [Chungbuk National University, Cheongju (Korea, Republic of)

    2007-08-15

    The purpose of this study was to evaluate the accuracy of each method of counting ribs on chest CT and to propose a new method: the anterior approach with using the sternocostal joints. CT scans of 38 rib lesions of 27 patients were analyzed (fracture: 25, metastasis: 11, benign bone disease: 2). Each lesion was independently counted by three radiologists with using three different methods for counting ribs: the sternoclavicular approach, the xiphisternal approach and the modified sternomanubrial approach. The rib lesions were divided into three parts of evaluation of each method according to the location of the lesion as follows: the upper part (between the first and fourth thoracic vertebra), the middle part (between the fifth and eighth) and the lower part (between the ninth and twelfth). The most accurate method was a modified sternomanubrial approach (99.1%). The accuracies of a xiphisternal approach and a sternoclavicular approach were 95.6% and 88.6%, respectively. A modified sternomanubrial approach showed the highest accuracies in all three parts (100%, 100% and 97.9%, respectively). We propose a new method for counting ribs, the modified sternomanubrial approach, which was more accurate than the known methods in any parts of the bony thorax, and it may be an easier and quicker method than the others in clinical practice.

  6. Early intravenous ibuprofen decreases narcotic requirement and length of stay after traumatic rib fracture.

    Science.gov (United States)

    Bayouth, Lilly; Safcsak, Karen; Cheatham, Michael L; Smith, Chadwick P; Birrer, Kara L; Promes, John T

    2013-11-01

    Pain control after traumatic rib fracture is essential to avoid respiratory complications and prolonged hospitalization. Narcotics are commonly used, but adjunctive medications such as nonsteroidal anti-inflammatory drugs may be beneficial. Twenty-one patients with traumatic rib fractures treated with both narcotics and intravenous ibuprofen (IVIb) (Treatment) were retrospectively compared with 21 age- and rib fracture-matched patients who received narcotics alone (Control). Pain medication requirements over the first 7 hospital days were evaluated. Mean daily IVIb dose was 2070 ± 880 mg. Daily intravenous morphine-equivalent requirement was 19 ± 16 vs 32 ± 24 mg (P pain scores were lower in the Treatment group (P rib fractures significantly decreases narcotic requirement and results in clinically significant decreases in hospital length of stay. IVIb therapy should be initiated in patients with traumatic rib fractures to improve patient comfort and reduce narcotic requirement.

  7. Multiple Rib Nonunion: Open Reduction and Internal Fixation and Iliac Crest Bone Graft Aspirate.

    Science.gov (United States)

    Kaplan, Daniel J; Begly, John; Tejwani, Nirmal

    2017-08-01

    Rib fractures are a common chest injury that can typically be treated nonoperatively. However, a percentage of these will go on to nonunion, either because of unique characteristics of the fracture itself or because of a variety of poor healing factors of the host. If a patient has continued symptomology beyond 3 months, surgeons may consider operative management. Although isolated resection of fibrous scar tissue from the nonunion site may be sufficient in some cases, it may also be necessary to provide additional structural integrity to the rib depending on the extent of the fracture pattern and resection. This goal can be achieved operatively with rib plating and bone grafting to promote healing. This video demonstrates the use of plating in the treatment of rib nonunion. It begins with relevant background information on rib fractures and nonunions, then details the approach, open reduction and internal fixation of 3 ribs using plates and bone graft aspirate. Pearls and pitfalls are included during the surgical technique aspect of the video to both help guide surgeons new to the procedure and provide potentially advantageous technical details to more experienced surgeons.

  8. Development of a socket-type rib coaptation device made of poly-L-lactide fibers: feasibility study in a canine model

    Science.gov (United States)

    Komatsu, Teruya; Sakaguchi, Yasuto; Muranishi, Yusuke; Yutaka, Yojiro; Date, Hiroshi; Nakamura, Tatsuo

    2018-01-01

    Background Costal coaptation pins made of poly-L-lactide (PLA) are clinically available for fixing surgically divided ribs. However, the clinical results of such rib fixation have not been completely satisfactory. We aimed to develop a new rib coaptation socket system and explore its clinical applicability. Methods We surgically divided three consecutive ribs of each beagle dog, and rib coaptation sockets were implanted to stabilize each rib. Fifteen 3-dimensional (3D)-printed and 30 PLA fiber knitted sockets were implanted in five and ten dogs, respectively, to stabilize the artificially divided ribs. Mechanical analysis of the sockets and radiographical examination of costal fixation were performed to evaluate the effectiveness of the newly developed socket system for rib stabilization. Results All 15 ribs with 3D-printed sockets had displaced 1 month after the operation. Three ribs in one dog with implanted PLA fiber knitted sockets were displaced radiographically after 1 month, and the grade of displacement remained unchanged after 6 months. The remaining 27 ribs fixed with PLA fiber knitted sockets did not show any displacement. Conclusions The PLA fiber knitted rib coaptation socket system was sufficiently durable for the stabilization of divided ribs with biocompatibility. This promising finding can be applied for clinical stabilization of divided ribs. PMID:29850125

  9. Rib fractures predict incident limb fractures: results from the European prospective osteoporosis study.

    Science.gov (United States)

    Ismail, A A; Silman, A J; Reeve, J; Kaptoge, S; O'Neill, T W

    2006-01-01

    Population studies suggest that rib fractures are associated with a reduction in bone mass. While much is known about the predictive risk of hip, spine and distal forearm fracture on the risk of future fracture, little is known about the impact of rib fracture. The aim of this study was to determine whether a recalled history of rib fracture was associated with an increased risk of future limb fracture. Men and women aged 50 years and over were recruited from population registers in 31 European centres for participation in a screening survey of osteoporosis (European Prospective Osteoporosis Study). Subjects were invited to complete an interviewer-administered questionnaire that included questions about previous fractures including rib fracture, the age of their first fracture and also the level of trauma. Lateral spine radiographs were performed and the presence of vertebral deformity was determined morphometrically. Following the baseline survey, subjects were followed prospectively by annual postal questionnaire to determine the occurrence of clinical fractures. The subjects included 6,344 men, with a mean age of 64.2 years, and 6,788 women, with a mean age of 63.6 years, who were followed for a median of 3 years (range 0.4-5.9 years), of whom 135 men (2.3%) and 101 women (1.6%) reported a previous low trauma rib fracture. In total, 138 men and 391 women sustained a limb fracture during follow-up. In women, after age adjustment, those with a recalled history of low trauma rib fracture had an increased risk of sustaining 'any' limb fracture [relative hazard (RH)=2.3; 95% CI 1.3, 4.0]. When stratified by fracture type the predictive risk was more marked for hip (RH=7.7; 95% CI 2.3, 25.9) and humerus fracture (RH=4.5; 95% CI 1.4, 14.6) than other sites (RH=1.6; 95% CI 0.6, 4.3). Additional adjustment for prevalent vertebral deformity and previous (non-rib) low trauma fractures at other sites slightly reduced the strength of the association between rib fracture and

  10. [Relationship between PMI and ATR-FTIR Spectral Changes in Swine Costal Cartilages and Ribs].

    Science.gov (United States)

    Yao, Yao; Wang, Qi; Jing, Xiao-li; Li, Bing; Zhang, Yin-ming; Wang, Zhi-jun; Li, Cheng-zhi; Lin, Han-cheng; Zhang, Ji; Huang, Ping; Wang, Zhen-yuan

    2016-02-01

    To analyze postmortem chemical changes in Landrace costal cartilages and ribs using attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy, and to provide a novel technique for estimation of postmortem interval (PMI). The swines were sacrificed by hemorrhage and their costal cartilages and ribs were kept in 20 degrees C. The chemical analysis of the costal cartilages and ribs were performed using ATR-FTIR every 72 h. The correlation between the certain spectral parameters and PMI was also analyzed. The time-dependent changes of costal cartilages were more significant than ribs. There were no obvious changes for the main absorbance bands position, and some absorbance band ratios showed time-dependent changes and significant correlations with the PMI. ATR-FTIR has the ability to analyze postmortem chemical changes of the swine costal cartilages and ribs, and it can be a new method to estimate PMI based on spectroscopy.

  11. [Tuberculosis of the spine and ribs].

    Science.gov (United States)

    Wishnitzer, R; Landow, Z; Sagiv, S; Rozenhack, M; Eliraz, A

    1991-11-15

    Tuberculosis of the spine or ribs is uncommon, occurring in less than 1% of patients with tuberculosis (TB). 2 women are presented who recently immigrated from Ethiopia and India, respectively. One, aged 55, presented with chest pain, fatigue and several masses under the skin of the scalp. Chest X-ray and CT scan suggested Pancoast tumor, and the lateral parts of the first 2 right ribs were absent. The origin of the patient, clinical findings and positive PPD suggested TB of the ribs and anti-TB therapy resulted in cure. The diagnosis was later confirmed by a positive culture. The other woman, aged 68, presented with fatigue, mild abdominal pain and axillary lymphadenopathy. The PPD was positive and X-ray showed widening of the mediastinum. A caseating granuloma with Langhans epithelioid cells was found in a lymph node. Flaccid paraparesis developed before therapy was started. CT scan showed a typical picture of TB affecting the T3-T6 vertebrae. Drainage of a cold abscess of the spine via the anterior approach was followed by anti-TB therapy. Culture of a biopsied lymph node and of pus obtained at operation confirmed the diagnosis of TB. The patient died 2 months later from gastrointestinal bleeding. Awareness of the unusual presentations of various forms of TB is mandatory in countries with immigration from countries in which TB is still common.

  12. The Place of Ultrasonography in the Evaluation of Rib Fractures

    OpenAIRE

    Fulya Bakılan; Gökhan Yüce; Ahmet Çağdaş Biçen; Tanju Keten

    2015-01-01

    Objective: The aim of this study was to investigate whether ultrasonography is superior to chest x-ray in detecting rib fractures in patients with minor blunt chest trauma and chest pain. Materials and Methods: Ultrasonography findings of 32 patients with minor blunt chest trauma showing no evidence of a rib fracture on anteroposterior chest x-rays, were documented. Presence of cortical discontinuities, acoustic shadows, reverberation artifacts, and hematoma by ultrasonography was...

  13. Flexural strength and behaviour of SFRSCC ribbed slab under four point bending

    Science.gov (United States)

    Ahmad, Hazrina; Hashim, Mohd Hisbany Mohd; Bakar, Afidah Abu; Hamzah, Siti Hawa; Rahman, Fadhillah Abdul

    2017-11-01

    An experimental investigation was carried out to study the ultimate strength and behaviour of SFRSCC ribbed slab under four point bending. Comparison was been made between ribbed slab that was fully reinforced with steel fibres (SFWS) with conventionally reinforced concrete ribbed slab (CS and CRC). The volume fraction of the 35 mm hooked end steel fibres used in the mix was 1% (80 kg/m3) with the aspect ratio of 65. Three full scale slab samples with the dimension of 2.8 x 1.2 m with 0.2 m thickness was constructed for the purpose of this study. The slab samples was loaded until failure in a four point bending test. As a whole, based on the results, it can be concluded that the performance of the steel fiber reinforced samples (SFWS) was found to be almost equivalent to the conventionally reinforced concrete ribbed slab sample (CRC).

  14. Hydraulic conductivity of compacted clay frozen and thawed in situ

    International Nuclear Information System (INIS)

    Benson, C.H.; Othman, M.A.

    1993-01-01

    A large specimen of compacted clay (diameter = 298 mm; thickness = 914 mm) was subjected to freeze-thaw in the field for 60 days. Afterward, the hydraulic conductivity was measured. The hydraulic conductivity of the entire specimen remained essentially unchanged, but increases in hydraulic conductivity of 1.5-2 orders of magnitude were observed above the freezing plane. The increase in hydraulic conductivity was highest at the top of the specimen and decreased with depth. Changes in hydraulic conductivity also occurred at depths 150 mm below the freezing plane, where desiccation occurred because of water redistribution. Numerous horizontal and vertical cracks formed in the soil mass. Dissection of the sample after permeation revealed that the cracks were laden with water. Cracking was greatest at the surface and became less frequent with depth. For depths greater than 150 mm below the freezing plane, cracking was absent. The frequency of cracks is consistent with principles of mechanistic models of soil freezing. The results of laboratory tests were used to predict the hydraulic conductivity of the large specimen. Tests were conducted on specimens subjected to various freeze-thaw cycles, temperature gradients, and states of stress. It was found that the predicted hydraulic conductivities were lower than those measured on the large specimen, but they closely resembled the trend in hydraulic conductivity with depth

  15. Tree height and tropical forest biomass estimation

    Science.gov (United States)

    M.O. Hunter; M. Keller; D. Vitoria; D.C. Morton

    2013-01-01

    Tropical forests account for approximately half of above-ground carbon stored in global vegetation. However, uncertainties in tropical forest carbon stocks remain high because it is costly and laborious to quantify standing carbon stocks. Carbon stocks of tropical forests are determined using allometric relations between tree stem diameter and height and biomass....

  16. Does initial spacing influence crown and hydraulic architecture of Eucalyptus marginata?

    Science.gov (United States)

    Grigg, A H; Macfarlane, C; Evangelista, C; Eamus, D; Adams, M A

    2008-05-01

    Long-term declines in rainfall in south-western Australia have resulted in increased interest in the hydraulic characteristics of jarrah (Eucalyptus marginata Donn ex Smith) forest established in the region's drinking water catchments on rehabilitated bauxite mining sites. We hypothesized that in jarrah forest established on rehabilitated mine sites: (1) leaf area index (L) is independent of initial tree spacing; and (2) more densely planted trees have less leaf area for the same leaf mass, or the same sapwood area, and have denser sapwood. Initial stand densities ranged from about 600 to 9000 stems ha(-1), and trees were 18 years old at the time of sampling. Leaf area index was unaffected by initial stand density, except in the most sparsely stocked stands where L was 1.2 compared with 2.0-2.5 in stands at other spacings. The ratio of leaf area to sapwood area (A(l):A(s)) was unaffected by tree spacing or tree size and was 0.2 at 1.3 m height and 0.25 at the crown base. There were small increases in sapwood density and decreases in leaf specific area with increased spacing. Tree diameter or basal area was a better predictor of leaf area than sapwood area. At the stand scale, basal area was a good predictor of L (r(2) = 0.98, n = 15) except in the densest stands. We conclude that the hydraulic attributes of this forest type are largely independent of initial tree spacing, thus simplifying parameterization of stand and catchment water balance models.

  17. Diameter growth performance of tree functional groups in Puerto Rican secondary tropical forests

    Directory of Open Access Journals (Sweden)

    Patricia Adame

    2014-04-01

    Full Text Available Aim of study: Understanding the factors that control tree growth in successional stands is particularly important for quantifying the carbon sequestration potential and timber yield of secondary tropical forests. Understanding the factors that control tree growth in successional stands is particularly important for quantifying the carbon sequestration potential and timber yield of secondary tropical forests. Yet, the high species diversity of mixed tropical forests, including many uncommon species, hinders the development of species-specific diameter growth models.Area of study: In these analyses, we grouped 82 species from secondary forests distributed across 93 permanent plots on the island of Puerto Rico.Material and Methods: Species were classified according to regeneration strategy and adult height into six functional groups. This classification allowed us to develop a robust diameter growth model using growth data collected from 1980-1990. We used mixed linear model regression to analyze tree diameter growth as a function of individual tree characteristics, stand structure, functional group and site factors.Main results: The proportion of variance in diameter growth explained by the model was 15.1%, ranging from 7.9 to 21.7%. Diameter at breast height, stem density and functional group were the most important predictors of tree growth in Puerto Rican secondary forest. Site factors such as soil and topography failed to predict diameter growth.Keywords: Caribbean forests; growth model; tropical forest succession; Puerto Rico.

  18. Biosorbable poly-L-lactide rib-connecting pins may reduce acute pain after thoracotomy.

    Science.gov (United States)

    Iwasaki, A; Hamatake, D; Shirakusa, T

    2004-02-01

    Conventional thoracotomy is currently used as a standard procedure, and is often required to treat numerous diseases. Additionally, rib resections are occasionally required to maintain an adequate field of view for surgery. The benefits of using rib pins for chest closure following such procedures have not yet been established. This study sought to evaluate the usefulness of rib pins in reducing acute postoperative pain. Thirty-three consecutive patients with lung cancer underwent lobectomies using the posterolateral approach. The patients were rib-resected and reconstructed with two techniques: 21 patients with absorbable rib pins (ARP group) and 12 patients by ligation with absorbable sutures (LAS group). Intensity of pain was assessed during the 3 days immediately following surgery. The two groups were assessed using the visual analogue scale (VAS) as a pain scale, amounts consumed of patient-controlled analgesics (PCA), and additional chest x-rays. On the first day following surgery, the mean VAS intensity of the ARP group for patient motion was 2.71 +/- 2.14, compared to 5.33 +/- 2.99 in the LAS group. After three days, the mean score for the ARP group was 1.98 +/- 1.89, compared to 4.60 +/- 1.97 in the LAS group. Scores in the ARP group were significantly lower than in the LAS group one day and three days following thoracotomy. The LAS group (55.0 +/- 15.9 times) made more frequent requests than the ARP group (16.1 +/- 10.3 times). The PCA requirement was also significantly lower in the ARP group. Excessive derangement of the rib (grade 2) was found in one case (4.7 %) in the ARP group compared to five cases (41.6 %) in the LAS group. Rib shifts were seen in numerous cases in the LAS group compared to the ARP group as measured by chest x-rays. Use of absorbable rib pins reduced postoperative pain and may improve long-term prospects for the post-thoracotomy course.

  19. Small female rib cage fracture in frontal sled tests.

    Science.gov (United States)

    Shaw, Greg; Lessley, David; Ash, Joseph; Poplin, Jerry; McMurry, Tim; Sochor, Mark; Crandall, Jeff

    2017-01-02

    The 2 objectives of this study are to (1) examine the rib and sternal fractures sustained by small stature elderly females in simulated frontal crashes and (2) determine how the findings are characterized by prior knowledge and field data. A test series was conducted to evaluate the response of 5 elderly (average age 76 years) female postmortem human subjects (PMHS), similar in mass and size to a 5th percentile female, in 30 km/h frontal sled tests. The subjects were restrained on a rigid planar seat by bilateral rigid knee bolsters, pelvic blocks, and a custom force-limited 3-point shoulder and lap belt. Posttest subject injury assessment included identifying rib cage fractures by means of a radiologist read of a posttest computed tomography (CT) and an autopsy. The data from a motion capture camera system were processed to provide chest deflection, defined as the movement of the sternum relative to the spine at the level of T8.  A complementary field data investigation involved querying the NASS-CDS database over the years 1997-2012. The targeted cases involved belted front seat small female passenger vehicle occupants over 40 years old who were injured in 25 to 35 km/h delta-V frontal crashes (11 to 1 o'clock). Peak upper shoulder belt tension averaged 1,970 N (SD = 140 N) in the sled tests. For all subjects, the peak x-axis deflection was recorded at the sternum with an average of -44.5 mm or 25% of chest depth. The thoracic injury severity based on the number and distribution of rib fractures yielded 4 subjects coded as Abbreviated Injury Scale (AIS) 3 (serious) and one as AIS 5 (critical). The NASS-CDS field data investigation of small females identified 205 occupants who met the search criteria. Rib fractures were reported for 2.7% of the female occupants. The small elderly test subjects sustained a higher number of rib cage fractures than expected in what was intended to be a minimally injurious frontal crash test condition. Neither field studies nor

  20. Prognosis of Primary and Recurrent Chondrosarcoma of the Rib.

    Science.gov (United States)

    Roos, Eva; van Coevorden, Frits; Verhoef, Cornelis; Wouters, Michel W; Kroon, Herman M; Hogendoorn, Pancras C W; van Houdt, Winan J

    2016-03-01

    Chondrosarcoma of the rib is a rare disease. Although surgery is the only curative treatment option, rib resection with an adequate margin can be challenging and local recurrence is a frequent problem. In this study, the prognosis of primary and recurrent chondrosarcoma of the rib is reported. Retrospective analysis was performed of patients treated for chondrosarcoma of the rib between 1984 and 2014 in three major tertiary referral centers in The Netherlands. Clinical and histopathological features were analyzed for their prognostic value using Kaplan-Meier and Cox proportional hazard analysis. Endpoints were set at local recurrent disease, metastasis rate, or death. Overall, 76 patients underwent a resection for a primary chondrosarcoma, and 26 patients underwent a resection for a recurrent chondrosarcoma. Five-year overall survival in the primary group was 90%, local recurrence rate was 17%, and metastasis rate was 12%. The 5-year outcome after recurrent chondrosarcoma was lower, with an overall survival of 65%, local recurrence rate of 27%, and metastasis rate of 27%. For primary chondrosarcoma, tumor size >5 cm and a positive resection margin were correlated with worse overall survival [hazard ratio (HR) 3.28, 95% confidence interval (CI) 1.03-10.44; HR 2.92, 95% CI 1.03-8.25). A higher histological grade was correlated with a higher local recurrence and metastasis rate (HR 5.92, 95% CI 1.11-31.65; HR 6.96, 95% CI 1.15-42.60). Surgical resection of both primary and recurrent chondrosarcoma of the rib is an effective treatment strategy. The oncological outcome after surgery is worse in tumors >5 cm, in tumors with positive resection margins and grade 3 chondrosarcoma.

  1. Number of rib fractures thresholds independently predict worse outcomes in older patients with blunt trauma.

    Science.gov (United States)

    Shulzhenko, Nikita O; Zens, Tiffany J; Beems, Megan V; Jung, Hee Soo; O'Rourke, Ann P; Liepert, Amy E; Scarborough, John E; Agarwal, Suresh K

    2017-04-01

    There have been conflicting reports regarding whether the number of rib fractures sustained in blunt trauma is associated independently with worse patient outcomes. We sought to investigate this risk-adjusted relationship among the lesser-studied population of older adults. A retrospective review of the National Trauma Data Bank was performed for patients with blunt trauma who were ≥65 years old and had rib fractures between 2009 and 2012 (N = 67,695). Control data were collected for age, sex, injury severity score, injury mechanism, 24 comorbidities, and number of rib fractures. Outcome data included hospital mortality, hospital and intensive care unit durations of stay, duration of mechanical ventilation, and the occurrence of pneumonia. Multiple logistic and linear regression analyses were performed. Sustaining ≥5 rib fractures was associated with increased intensive care unit admission (odds ratio: 1.14, P rib fractures was associated with an increased incidence of pneumonia (odds ratio: 1.32, P rib fractures was associated with increased mortality (odds ratio: 1.51, P rib fractures is a significant predictor of worse outcomes independent of patient characteristics, comorbidities, and trauma burden. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Osteoradionecrosis of the Ribs following Breast Radiotherapy

    Directory of Open Access Journals (Sweden)

    Luke Nicholls

    2015-08-01

    Full Text Available Introduction: Osteoradionecrosis (ORN of the chest wall is a rare complication after whole-breast radiotherapy (RT. Herein, we report a case of ORN involving the underlying ribs following adjuvant whole-breast RT using standard fractionation and conduct a review of the literature. Case Report: A previously well 43-year-old female with right-sided, early-stage, node-negative breast cancer was treated with breast-conserving surgery. She subsequently underwent adjuvant whole-breast RT receiving 50 Gy in 25 fractions over 5 weeks using standard tangential photon fields with 6 MV photons followed by an electron boost of 10 Gy in 5 fractions according to International Commission on Radiation Units (ICRU requirements. Eleven months after RT, the patient developed right lateral chest wall pain, with magnetic resonance imaging (MRI demonstrating two fractures involving the underlying right fifth and sixth ribs associated with fatty marrow changes in the second to sixth ribs, thus raising the possibility of ORN. Treatments including hyperbaric oxygen, pentoxifylline and vitamin E were used with symptomatic improvements. There was demonstrable resolution on follow-up MRI at 2.5 years. Conclusion: The incidence of ORN utilising modern RT techniques and standard fractionation is rare. Numerous treatments are available, with variable response rates. Emerging evidence of predictive gene profiling to estimate the risk of radiation sensitivity may assist in individualising preventative strategies to mitigate the risk of ORN.

  3. Tree height integrated into pantropical forest biomass estimates

    NARCIS (Netherlands)

    Feldpausch, T.R.; Lloyd, J.; Lewis, S.L.; Brienen, R.J.W.; Gloor, M.; Montegudo Mendoza, A.; Arets, E.J.M.M.

    2012-01-01

    Aboveground tropical tree biomass and carbon storage estimates commonly ignore tree height (H). We estimate the effect of incorporating H on tropics-wide forest biomass estimates in 327 plots across four continents using 42 656 H and diameter measurements and harvested trees from 20 sites to answer

  4. New bone post-processing tools in forensic imaging: a multi-reader feasibility study to evaluate detection time and diagnostic accuracy in rib fracture assessment.

    Science.gov (United States)

    Glemser, Philip A; Pfleiderer, Michael; Heger, Anna; Tremper, Jan; Krauskopf, Astrid; Schlemmer, Heinz-Peter; Yen, Kathrin; Simons, David

    2017-03-01

    The aim of this multi-reader feasibility study was to evaluate new post-processing CT imaging tools in rib fracture assessment of forensic cases by analyzing detection time and diagnostic accuracy. Thirty autopsy cases (20 with and 10 without rib fractures in autopsy) were randomly selected and included in this study. All cases received a native whole body CT scan prior to the autopsy procedure, which included dissection and careful evaluation of each rib. In addition to standard transverse sections (modality A), CT images were subjected to a reconstruction algorithm to compute axial labelling of the ribs (modality B) as well as "unfolding" visualizations of the rib cage (modality C, "eagle tool"). Three radiologists with different clinical and forensic experience who were blinded to autopsy results evaluated all cases in a random manner of modality and case. Rib fracture assessment of each reader was evaluated compared to autopsy and a CT consensus read as radiologic reference. A detailed evaluation of relevant test parameters revealed a better accordance to the CT consensus read as to the autopsy. Modality C was the significantly quickest rib fracture detection modality despite slightly reduced statistic test parameters compared to modalities A and B. Modern CT post-processing software is able to shorten reading time and to increase sensitivity and specificity compared to standard autopsy alone. The eagle tool as an easy to use tool is suited for an initial rib fracture screening prior to autopsy and can therefore be beneficial for forensic pathologists.

  5. New technique for fixing rib fracture with bioabsorbable plate.

    Science.gov (United States)

    Oyamatsu, Hironori; Ohata, Norihisa; Narita, Kunio

    2016-09-01

    Fixation of a bone fracture with a bioabsorbable plate made of poly-L-lactide and hydroxyapatite has received attention. We adopted this technique for a rib fracture by bending the plate into a U-shape and fixing it with suture through the holes in the mesh of the plate and holes that are drilled in the edge of the fractured rib. The suture is also wound around the plate. © The Author(s) 2016.

  6. Operation of a hydraulic elevator system

    Energy Technology Data Exchange (ETDEWEB)

    Lazarev, G.A.; Li, Yu.V.; Bezuglov, N.N.

    1983-03-01

    The paper describes the hydraulic elevator system in the im. 50-letiya Oktyabr'skoi Revolutsii mine in the Karaganda basin. The system removes water and coal from the sump of a skip mine shaft. Water influx rate per day to the sump does not exceed 120 m/sup 3/, weight of coal falling from the skip is about 5,000 kg per day. The sump, 85 m deep, is closed by a screen. The elevator system consists of two pumps (one is used as a reserve pump) with a capacity of 300 m/sup 3/h. When water level exceeds the maximum permissive limit the pump is activated by an automatic control system. The coal and water mixture pumped from the sump bottom is directed to a screen which separates coal from water. Coal is fed to a coal hopper and water is pumped to a water tank. The hydraulic elevator has a capacity of 80 m/sup 3/ of mixture per hour. The slurry is tranported by a pipe of 175 mm diameter. Specifications of the pumps and pipelines are given. A scheme of the hydraulic elevator system is also shown. Economic aspects of hydraulic elevator use for removal of water and coal from deep sumps of skip shafts in the Karaganda basin also are discussed.

  7. Influence of Drought on the Hydraulic Efficiency and the Hydraulic Safety of the Xylem - Case of a Semi-arid Conifer.

    Science.gov (United States)

    Gentine, P.; Guerin, M. F.; von Arx, G.; Martin-Benito, D.; Griffin, K. L.; McDowell, N.; Pockman, W.; Andreu-Hayles, L.

    2017-12-01

    Recent droughts in the Southwest US have resulted in extensive mortality in the pinion pine population (Pinus Edulis). An important factor for resiliency is the ability of a plant to maintain a functional continuum between soil and leaves, allowing water's motion to be sustained or resumed. During droughts, loss of functional tracheids happens through embolism, which can be partially mitigated by increasing the hydraulic safety of the xylem. However, higher hydraulic safety is usually achieved by building narrower tracheids with thicker walls, resulting in a reduction of the hydraulic efficiency of the xylem (conductivity per unit area). Reduced efficiency constrains water transport, limits photosynthesis and might delay recovery after the drought. Supporting existing research on safety-efficiency tradeoff, we test the hypothesis that under dry conditions, isohydric pinions grow xylem that favor efficiency over safety. Using a seven-year experiment with three watering treatments (drought, control, irrigated) in New Mexico, we investigate the effect of drought on the xylem anatomy of pinions' branches. We also compare the treatment effect with interannual variations in xylem structure. We measure anatomical variables - conductivities, cell wall thicknesses, hydraulic diameter, cell reinforcement and density - and preliminarily conclude that treatment has little effect on hydraulic efficiency while hydraulic safety is significantly reduced under dry conditions. Taking advantage of an extremely dry year occurrence during the experiment, we find a sharp increase in vulnerability for xylem tissues built the same year.

  8. Clinical significance of conventional rib series in patients with minor thoracic trauma

    Energy Technology Data Exchange (ETDEWEB)

    Hoffstetter, P.; Dornia, C. [Asklepios Medical Center, Bad Abbach (Germany). Radiology; University Medical Center Regensburg (Germany). Radiology; Wagner, M.; Niessen, C.; Dendl, L.M.; Stroszczynski, C.; Schreyer, A.G. [University Medical Center Regensburg (Germany). Radiology; Al Suwaidi, M.H. [Asklepios Medical Center, Bad Abbach (Germany). Rheumatology/Clinical Immmunology

    2014-09-15

    Background: Conventional rib series (RS) represent a dedicated radiographic technique to visualize the bony parts of the chest wall. The method is commonly used to evaluate minor thoracic trauma, frequently in combination with chest radiographs (CRs). The aim of this study is to asses the clinical relevance of rib fractures diagnosed by RS in minor thoracic trauma. Methods: Retrospective study of 669 patients who received RS for the evaluation of minor thoracic trauma. 405 of the 669 patients received an additional CR. Radiological reports were classified into fracture versus no fracture. Patients were divided into four groups depending on the clinical follow-up. The findings of RS and CR were analyzed using the McNemar test. The statistical significance between the results of the radiographic examinations and the clinical follow-up was analyzed by the Chi-Square test and the Kruskal-Wallis test. Results: We included 669 patients (61.4% men, 38.6% women, median age: 51 years, range: 13-92 years). Analyzing the reports of 669 patients who received RS, 157 (23.5%) patients were diagnosed with at least one fractured rib while no fracture was found in 512 (76.5%) patients. Considering the 157 patients with fractured ribs, 73 (46.8%) had a single fracture, 38 (24.4%) and two fractures and 45 (28.8%) had more than two fractures. When assessing the 405 CRs, we detected 69 (17%) fractures while the corresponding RS of the same patients revealed 87 (21.5%) fractures (p < 0.05). Concerning all patients with rib fractures, 63.1% received medical therapy, while 64.5% of those patients without a radiologically documented fracture also received therapy (p = 0.25). Conclusion: Our results suggest a limited clinical value of detected rib fractures based on RS. Despite being superior compared to CR in diagnosing rib fractures, the results from RS seem to have no significant influence on further clinical management and therapeutic measures. Minor thoracic trauma should be evaluated

  9. Clinical significance of conventional rib series in patients with minor thoracic trauma

    International Nuclear Information System (INIS)

    Hoffstetter, P.; Dornia, C.; University Medical Center Regensburg; Wagner, M.; Niessen, C.; Dendl, L.M.; Stroszczynski, C.; Schreyer, A.G.; Al Suwaidi, M.H.

    2014-01-01

    Background: Conventional rib series (RS) represent a dedicated radiographic technique to visualize the bony parts of the chest wall. The method is commonly used to evaluate minor thoracic trauma, frequently in combination with chest radiographs (CRs). The aim of this study is to asses the clinical relevance of rib fractures diagnosed by RS in minor thoracic trauma. Methods: Retrospective study of 669 patients who received RS for the evaluation of minor thoracic trauma. 405 of the 669 patients received an additional CR. Radiological reports were classified into fracture versus no fracture. Patients were divided into four groups depending on the clinical follow-up. The findings of RS and CR were analyzed using the McNemar test. The statistical significance between the results of the radiographic examinations and the clinical follow-up was analyzed by the Chi-Square test and the Kruskal-Wallis test. Results: We included 669 patients (61.4% men, 38.6% women, median age: 51 years, range: 13-92 years). Analyzing the reports of 669 patients who received RS, 157 (23.5%) patients were diagnosed with at least one fractured rib while no fracture was found in 512 (76.5%) patients. Considering the 157 patients with fractured ribs, 73 (46.8%) had a single fracture, 38 (24.4%) and two fractures and 45 (28.8%) had more than two fractures. When assessing the 405 CRs, we detected 69 (17%) fractures while the corresponding RS of the same patients revealed 87 (21.5%) fractures (p < 0.05). Concerning all patients with rib fractures, 63.1% received medical therapy, while 64.5% of those patients without a radiologically documented fracture also received therapy (p = 0.25). Conclusion: Our results suggest a limited clinical value of detected rib fractures based on RS. Despite being superior compared to CR in diagnosing rib fractures, the results from RS seem to have no significant influence on further clinical management and therapeutic measures. Minor thoracic trauma should be evaluated

  10. Flow regime mapping of vertical two-phase downflow in a ribbed annulus

    International Nuclear Information System (INIS)

    Kielpinski, A.L.

    1992-01-01

    Two-phase flow regimes have been mapped for vertical, cocurrent downflow in a narrow annulus which is partially segmented by the presence of longitudinal ribs. This geometry and flow condition has application to the analysis of a Large-Break Loss of Coolant Accident (LB-LOCA) in the production K-Reactor at the Savannah River Site (SRS). The ribbed annular geometry, particularly the presence of non-sealing ribs, gives rise to some unique phenomenological features. The flow behavior is influenced by the partial segmentation of the annulus into four quadrants or subchannels. A random element is induced by the natural bowing of the slender tubes; the width of the azimuthal flow path between two subchannels at a given axial location is indeterminate, and can take on any value between zero and the maximum clearance of 7.6 x l0 -4 m. When the rib gap is zero at a given location, it is at a maximum 180P away at the same axial location. The range of rib gaps is spanned in a single test section, as it would be also in a reactor assembly. As a result of these effects, flow regime maps obtained by other researchers for downflow in annuli are not accurate for defining flow regimes in a ribbed annulus. Flow regime transitions similar to those noted by, e.g., Bamea, were observed; the locations of these transitions were displaced with respect to the transition equations derived by Bamea. Experimental bubble rise velocity measurements were also obtained in the same test section. The bubble rise velocities were much higher than expected from the theory developed for slug bubbles in tubes, unribbed annuli, and rectangular channels. An elliptical-cap bubble rises faster than a slug bubble of the same area. Large, slug-shaped bubbles injected into the test section were observed to reduce in size as they rose, due to interaction with a longitudinal rib. They thereby adopted a shape more like an elliptical-cap bubble, hence rising faster than the original slug bubble

  11. Continuous intercostal nerve blockade for rib fractures: ready for primetime?

    Science.gov (United States)

    Truitt, Michael S; Murry, Jason; Amos, Joseph; Lorenzo, Manuel; Mangram, Alicia; Dunn, Ernest; Moore, Ernest E

    2011-12-01

    Providing analgesia for patients with rib fractures continues to be a management challenge. The objective of this study was to examine our experience with the use of a continuous intercostal nerve block (CINB). Although this technique is being used, little data have been published documenting its use and efficacy. We hypothesized that a CINB would provide excellent analgesia, improve pulmonary function, and decrease length of stay (LOS). Consecutive adult blunt trauma patients with three or more unilateral rib fractures were prospectively studied over 24 months. The catheters were placed at the bedside in the extrathoracic, paravertebral location, and 0.2% ropivacaine was infused. Respiratory rate, preplacement (PRE) numeric pain scale (NPS) scores, and sustained maximal inspiration (SMI) lung volumes were determined at rest and after coughing. Parameters were repeated 60 minutes after catheter placement (POST). Hospital LOS comparison was made with historical controls using epidural analgesia. Over the study period, 102 patients met inclusion criteria. Mean age was 69 (21-96) years, mean injury severity score was 14 (9-16), and the mean number of rib fractures was 5.8 (3-10). Mean NPS improved significantly (PRE NPS at rest = 7.5 vs. POST NPS at rest = 2.6, p pain control, and shortens LOS in patients with rib fractures.

  12. MODELING AND DESIGN OF INNOVATIVE SMALL DIAMETER GRAVITY SEWERAGE SYSTEM

    Directory of Open Access Journals (Sweden)

    Tadeusz Nawrot

    2017-05-01

    Full Text Available The article presents modern methods of hydraulic design of an innovative small diameter gravity sewerage system. In this system, domestic wastewater is preliminary treated in septic tanks equipped with outlet filters, thus the effluent features are similar to those of clear water. Innovative non-return valves at the outlets eliminate introduction of air to the system and thus the flows can be treated as one-phase ones. Computer codes EPANET 2 and SWMM 5.0 were applied and compared. Two flow schemes typical for the sewerage system were implemented in EPANET 2, and the third - in a slightly modified SWMM 5.0. Simulation results were validated on empirical data obtained on a laboratory physical model, consisting of four tanks of minimum volumes 600 dm3 each, connecting PE pipelines of diameters 25 mm and 36 mm and relevant sanitary fittings. Water inflows, typical for domestic wastewater outflows from single homesteads, were provided by a pump. Water flows were measured using water meters with pulse outputs, and water levels in tanks by pressure transducers. Hydraulic characteristics of filters and non-return valves were provided. Simulation results showed good agreement with the empirical data. Ranges of values of design parameters, needed for successful application of both codes, were established and discussed.

  13. A comparison between rib fracture patterns in peri- and post-mortem compressive injury in a piglet model.

    Science.gov (United States)

    Bradley, Amanda L; Swain, Michael V; Neil Waddell, J; Das, Raj; Athens, Josie; Kieser, Jules A

    2014-05-01

    Forensic biomechanics is increasingly being used to explain how observed injuries occur. We studied infant rib fractures from a biomechanical and morphological perspective using a porcine model. We used 24, 6th ribs of one day old domestic pigs Sus scrofa, divided into three groups, desiccated (representing post-mortem trauma), fresh ribs with intact periosteum (representing peri-mortem trauma) and those stored at -20°C. Two experiments were designed to study their biomechanical behaviour fracture morphology: ribs were axially compressed and subjected to four-point bending in an Instron 3339 fitted with custom jigs. Morphoscopic analysis of resultant fractures consisted of standard optical methods, micro-CT (μCT) and Scanning Electron Microscopy (SEM). During axial compression fresh ribs did not fracture because of energy absorption capabilities of their soft and fluidic components. In flexure tests, dry ribs showed typical elastic-brittle behaviour with long linear load-extension curves, followed by short non-linear elastic (hyperelastic) behaviour and brittle fracture. Fresh ribs showed initial linear-elastic behaviour, followed by strain softening and visco-plastic responses. During the course of loading, dry bone showed minimal observable damage prior to the onset of unstable fracture. Frozen then thawed bone showed similar patterns to fresh bone. Morphologically, fresh ribs showed extensive periosteal damage to the tensile surface with areas of collagen fibre pull-out along the tensile surface. While all dry ribs fractured precipitously, with associated fibre pull-out, the latter feature was absent in thawed ribs. Our study highlights the fact that under controlled loading, fresh piglet ribs (representing perimortem trauma) did not fracture through bone, but was associated with periosteal tearing. These results suggest firstly, that complete lateral rib fracture in infants may in fact not result from pure compression as has been previously assumed; and

  14. First rib fractures: not always a hallmark of severe trauma-a report of three cases

    Directory of Open Access Journals (Sweden)

    Jaiswal Atin

    2013-08-01

    Full Text Available 【Abstract】According to medical literature, fracture of the first rib is quite rare and the bilateral condition is especially rare. This type of fracture is usually associated with severe intrathoracic trauma and other bony or neurovascular injuries, thus can be considered as a harbinger of major trauma. However here we present three cases of low velocity first rib fractures without any major trauma or multisystem injuries. All the three patients were treated conservatively and did well on simple analgesics and rest and had no early or late complications. It can be seen that not all the first rib fractures are associated with major trauma or multisystem injuries. There is a variant of first rib fracture with low velocity injuries which is not associated with any major complications in contrast to majority of first rib fractures associated with high velocity injuries. Causative factor of such injuries may be violent muscular contraction of scalenus anterior or serratus anterior, but not direct trauma. Key words: Rib fractures; Wounds and injuries; Multiple trauma

  15. Experimental investigation of cross-over jets in a rib-roughened trailing-edge cooling channel

    Science.gov (United States)

    Xue, Fei

    Increasing the rotor inlet temperature can dramatically increase the efficiency and power output of the gas turbine engine. However, the melting point of turbine blade material limits the realistic upper bound of the rotor inlet temperature. As a result, the development of high temperature turbine blade material and advanced turbine blade cooling technology determines the future of turbine blade engine. Adding impingement jet holes and rib turbulators in the inner cooling channel of the gas turbine blades are two effective ways to enhance the cooling effects. The purpose of this study is to figure out the influence of different combinations of jet holes and rib turbulators on the heat transfer efficiency. A tabletop scale test model is used in the study to simulate the cooling cavity of trailing edge and its feed channel in a real gas turbine blade. The Dimensional Analysis Theory is used in the study to eliminate the influence of scaling. Two different crossover slots are tested with 5 different rib arrangements, and each of the test geometries is tested for 6 jet Reynolds numbers ranging from 10,000 to 36,000. The two different crossover slots are the crossover slots with 0 and 5 degree tilt angles. The four different rib arrangements are ribs with 0 degree, 45 degree, 90 degree and 135 degree angles of attack with respect to the flow direction. Furthermore, a smooth test section (no ribs) was also tested. The steady state liquid crystal thermography is used to quantify the heat transfer performance of the target areas. The variation of Nusselt number versus Reynolds number is plotted for each of the 10 geometries. Also, the variation of Nusselt number versus Reynolds number are compared for different rib angles of attack with the same crossover slot tilt angle, and between different crossover slots tilt angles with the same rib angle. The results show that, the area-weighted average Nusselt number increases monotonically with the Reynolds number; the target

  16. Numerical simulations of heat transfer distribution of a two-pass square channel with V-rib turbulator and bleed holes

    Science.gov (United States)

    Kumar, Sourabh; Amano, R. S.; Lucci, Jose Martinez

    2013-08-01

    The blade tip region in gas turbine encounters high thermal loads due to temperature difference and hence efforts for high durability and safe operations are essential. Improved and robust methods of cooling are required to downgrade heat transfer rate to turbine blades. The blade tip regions, which are exposed to high gas flow, suffers high local thermal load which are due to external tip leakage. Jet impingement, pin cooling etc. are techniques used for cooling blades. A more usual way is to use serpentine passage with 180-degree turn. In this study, numerical simulation of heat transfer distribution of a two-pass square channel with rib turbulators and bleed holes were done. Periodical rib turbulators and bleed holes were used in the channel. The ribs arrangement were 60 degree V rib, 60 degree inverted V ribs, combination of 60 degree V rib at inlet and 60 inverted V rib at outlet section and combination of Inverted V at inlet and V rib at the outlet. The results were numerically computed using Fluent with Reynolds number of 12,500 and 28,500. Turbulence models used for computations were k-ω-SST and RSM. Temperature based and shear stress based techniques were used for heat transfer distribution prediction. The results for 60 degree V rib, 60 degree inverted V ribs were compared with the experimental results for validation of the results obtained. Detailed distribution shows distinctive peaks in heat transfer around bleed holes and rib turbulator. Comparisons of the overall performance of the models with different orientation of rib turbulator are presented. It is found that due to the combination of 60 degree inverted V rib in inlet and 60 V rib in outlet with bleed holes provides better heat treatment. It is suggested that the use of rib turbulator with bleed holes provides suitable for augmenting blade cooling to achieve an optimal balance between thermal and mechanical design requirements.

  17. Osteoblastic lesion screening with an advanced post-processing package enabling in-plane rib reading in CT-images.

    Science.gov (United States)

    Seuss, Hannes; Dankerl, Peter; Cavallaro, Alexander; Uder, Michael; Hammon, Matthias

    2016-05-20

    To evaluate screening and diagnostic accuracy for the detection of osteoblastic rib lesions using an advanced post-processing package enabling in-plane rib reading in CT-images. We retrospectively assessed the CT-data of 60 consecutive prostate cancer patients by applying dedicated software enabling in-plane rib reading. Reading the conventional multiplanar reconstructions was considered to be the reference standard. To simulate clinical practice, the reader was given 10 s to screen for sclerotic rib lesions in each patient applying both approaches. Afterwards, every rib was evaluated individually with both approaches without a time limit. Sensitivities, specificities, positive/negative predictive values and the time needed for detection were calculated depending on the lesion's size (largest diameter  10 mm). In 53 of 60 patients, all ribs were properly displayed in plane, in five patients ribs were partially displayed correctly, and in two patients none of the ribs were displayed correctly. During the 10-s screening approach all patients with sclerotic rib lesions were correctly identified reading the in-plane images (including the patients without a correct rib segmentation), whereas 14 of 23 patients were correctly identified reading conventional multiplanar images. Overall screening sensitivity, specificity, and positive/negative predictive values were 100/27.0/46.0/100 %, respectively, for in-plane reading and 60.9/100/100/80.4 %, respectively, for multiplanar reading. Overall diagnostic (no time limit) sensitivity, specificity, and positive/negative predictive values of in-plane reading were 97.8/92.8/74.6/99.5 %, respectively. False positive results predominantly occurred for lesions <5 mm in size. In-plane reading of the ribs allows reliable detection of osteoblastic lesions for screening purposes. The limited specificity results from false positives predominantly occurring for small lesions.

  18. Production of light radioactive ion beams (RIB) using inverse kinematics

    International Nuclear Information System (INIS)

    Das, J.J.; Sugathan, P.; Madhavan, N.; Madhusudhana Rao, P.V.; Jhingan, A.; Varughese, T.; Barua, S.; Nath, S.; Sinha, A.K.; Kumar, B.; Zacharias, J.

    2005-01-01

    At Nuclear Science Centre (NSC), New Delhi, we have implemented a facility to produce low energy light radioactive ion beams (RIBs) using (p,n) type of reactions in inverse kinematics. For this purpose primary beams from the 15-UD Pelletron accelerator impinged on a thin polypropylene foil mounted on a rotating/linearly moving target assembly. For efficiently separating the secondary beam from primary beam, the existing recoil mass spectrometer (RMS) HIRA was operated with new ion optics. Suitable hardware modifications were also made. Using this facility, we have extracted a 7 Be beam of purity better than 99% and spot-size ∼4 mm in diameter. This 7 Be beam has been utilized in a variety of experiments in the energy range of 15-22 MeV. Typical beam parameters are: intensity 10 4 pps, angular spread ±30 mrad and energy spread ±0.5 MeV. Development of appropriate detector setup/target arrangement were also made to perform these experiments. In this paper, we describe the implementation of this project

  19. A Rare Cause of Persistent Pulmonary Hypertension Resistant to Therapy in The Newborn: Short-Rib Polydactyly Syndrome

    Directory of Open Access Journals (Sweden)

    Nihat Demir

    2015-01-01

    Full Text Available Short-rib polydactyly syndrome is an autosomal recessively inherited lethal skeletal dysplasia. The syndrome is characterized by marked narrow fetal thorax, short extremities, micromelia, cleft palate/lip, polydactyly, cardiac and renal abnormalities, and genital malformations. In cases with pulmonary hypoplasia, persistent pulmonary hypertension of the newborn can develop. In this paper, we present a term newborn with persistent pulmonary hypertension of the newborn, which has developed secondary to short-rib polydactyly syndrome and was resistant to therapy with inhaled nitric oxide and oral sildenafil.

  20. Helmholtz resonance in a piezoelectric–hydraulic pump-based hybrid actuator

    International Nuclear Information System (INIS)

    Kim, Gi-Woo; Wang, K W

    2011-01-01

    This paper demonstrates that a hydraulically acting Helmholtz resonator can exist in a piezoelectric–hydraulic pump (PHP) based hybrid actuator, which in turn affects the volumetric efficiency of the PHP. The simulation and experimental results illustrate the effect of Helmholtz resonance on the flow rate performance of the PHP. The study also shows how to shift the Helmholtz resonant frequency to a higher value through changing parameters such as the cylinder diameter and the effective bulk modulus of the working fluid, which will improve the volumetric efficiency and broaden the operating frequency range of the PHP actuator

  1. Esophagogastric junction distensibility measurements during hydraulic dilation therapy in achalasia patients

    NARCIS (Netherlands)

    Kappelle, W.F.; Bogte, A.; Siersema, P.D.

    2016-01-01

    Increasing evidence suggests that esophagogastric junction (EGJ) distensibility is predictive of long-term clinical success after achalasia treatment. A new commercially available hydraulic dilation balloon is capable of measuring EGJ opening diameters whilst simultaneously dilating the EGJ.

  2. Biomechanical investigation of different surgical strategies for the treatment of rib fractures using a three-dimensional human respiratory model.

    Science.gov (United States)

    Shih, Kao-Shang; Truong, Thanh An; Hsu, Ching-Chi; Hou, Sheng-Mou

    2017-11-02

    Rib fracture is a common injury and can result in pain during respiration. Conservative treatment of rib fracture is applied via mechanical ventilation. However, ventilator-associated complications frequently occur. Surgical fixation is another approach to treat rib fractures. Unfortunately, this surgical treatment is still not completely defined. Past studies have evaluated the biomechanics of the rib cage during respiration using a finite element method, but only intact conditions were modelled. Thus, the purpose of this study was to develop a realistic numerical model of the human rib cage and to analyse the biomechanical performance of intact, injured and treated rib cages. Three-dimensional finite element models of the human rib cage were developed. Respiratory movement of the human rib cage was simulated to evaluate the strengths and limitations of different scenarios. The results show that a realistic human respiratory movement can be simulated and the predicted results were closely related to previous study (correlation coefficient>0.92). Fixation of two fractured ribs significantly decreased the fixation index (191%) compared to the injured model. This fixation may provide adequate fixation stability as well as reveal lower bone stress and implant stress compared with the fixation of three or more fractured ribs.

  3. [Diagnosis and treatment of rib fracture during spontaneous vaginal delivery].

    Science.gov (United States)

    Jovanović, Nebojša; Ristovska, Nataša; Bogdanović, Zorica; Petronijević, Miloš; Opalić, Jasna; Plećaš, Darko

    2013-01-01

    Progress of labor in multiparous women usually is not accompanied with risk of any kind of birth trauma. We report a very rare case of rib fracture in a neonate during vaginal delivery in the 39/40 week of gestation. The expulsion started spontaneously without any manipulation from the obstetrician. Live male newborn was delivered 4650 g. in weight, 55 cm long, with head circumference of 39 cm, Apgar score 9. The child was immediately examined by the neonatologist. Crepitations were palpable over the left hemithorax, and auscultatory on the left side inspiratory cracks. Finding was suspicious for rib fracture on the left side posteriorly and brachial plexus palsy, while other findings were normal. X-ray finding was inconclusive, but suspicious for fracture of the 4th, 5th, and 6th left rib posteriorly, without dislocation of bone fragments. There were no signs of pneumothorax. Dorsal position of the newborn was considered sufficient, accompanied with analgetics. X-ray was scheduled in a week because formation of the calus would be the only objective sign of previous rib fracture. On the control X-ray fracture lines were clearly visible on the 3rd, 4th, 5th 6th and 7th rib posteriorly, without dislocation of bone fragments with initial calus formation. The child was discharged from hospital in good condition after two weeks, for further outpatient care. With timely diagnostics of this very rare intrapartal fracture, adequate treatment, dorsal position and close control of clinical condition of the newborn, serious and potentially life threatening complications can be avoided.

  4. Naumoff short-rib polydactyly syndrome compounded with Mohr oral-facial-digital syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Young, L.W.; Wilhelm, L.L. [Loma Linda Univ., CA (United States). Medical Center; Zuppan, C.W. [Div. of Pediatric Pathology, Loma Linda University Medical Center, CA (United States); Clark, R. [Div. of Medical Genetics, Loma Linda University Medical Center, CA (United States)

    2001-01-01

    A stillborn baby boy had findings of severe constitutional dwarfism with short limbs, short ribs, and polydactyly that were consistent with Naumoff (type III) short-rib polydactyly syndrome. He also had additional congenital anomalies, including cleft palate, notching of the upper lip, small tongue with accessory sublingual tissue. These oral and pharyngeal anomalies were consistent with Mohr (type II) oral-facial-digital syndrome. We suggest the stillborn infant represented a compound of Naumoff short-rib polydactyly syndrome (SRPS-III) and Mohr oral-facial-digital syndrome (OFDS-II). (orig.)

  5. Smaller Anterior Cruciate Ligament Diameter Is a Predictor of Subjects Prone to Ligament Injuries: An Ultrasound Study

    Directory of Open Access Journals (Sweden)

    Parag Suresh Mahajan

    2015-01-01

    Full Text Available Purpose. To test if diameter of normal anterior cruciate ligament (ACL can be measured by ultrasound (US, to see if there is a relationship between smaller ACL diameter and ACL injury, and to assess agreement between radiologists in measuring ACL diameter in cases and matched controls. Materials and Methods. In this ethics committee-approved study, maximum diameter of ACL near tibial insertion site was measured by static and dynamic US study in 25 normal contralateral knees of subjects who suffered noncontact ACL injury and in 25 matched control subjects. Results. ACL was visualized as a thick linear hypoechoic band inserted approximately 11 mm caudal to the tibial plateau and the intercondylar eminence. Maximum diameter of contralateral ACL near tibial insertion site among injured subjects was significantly smaller than in noninjured subjects (0.62 ± 0.07 cm versus 0.81 ± 0.06 cm; P<0.0001. In the regression analysis, the diameter of ACL near tibial insertion site was found significantly proportional to body weight and not significantly associated to height, gender, and age. Conclusion. Diameter of normal ACL near tibial insertion site can be measured by US and the maximum diameter is significantly smaller among subjects with noncontact ACL injury. US is a promising modality that can be used as an excellent screening test to detect subjects especially aspiring athletes prone to ACL injury. Very strong agreement was observed between radiologists in measuring ACL diameter.

  6. Perinatally lethal short rib-polydactyly syndromes. Pt. 1

    International Nuclear Information System (INIS)

    Sillence, D.; Kozlowski, K.; Bar-ziv, J.; Fuhrmann-Rieger, A.; Fuhrmann, W.; Pascu, F.

    1987-01-01

    Thirteen newborns with lethal short rib-polydactyly (SRP) have been reviewed, 11 with SRP type 3 (Verma-Naumoff) and 2 with SRP tye 2 (Majewski). In the former group there were three sets of siblings. The excess of males with SRP type III (Verma-Naumoff) is confirmed in this present study. A high frequency of phenotypic females including sex-reversed constitutional males with SRP type 1 (Saldino-Noonan) is in marked contrast to these findings in SRP type 3. Possible hypotheses include variable expressivity in non-Majewski short rib-polydactyly syndromes with sex-reversed and constitutional female cases tending to show more severe phenotypic expression both in terms of major anomalies and skeletal dysplastic effects. (orig.)

  7. Guideline-Driven Care Improves Outcomes in Patients with Traumatic Rib Fractures.

    Science.gov (United States)

    Flarity, Kathleen; Rhodes, Whitney C; Berson, Andrew J; Leininger, Brian E; Reckard, Paul E; Riley, Keyan D; Shahan, Charles P; Schroeppel, Thomas J

    2017-09-01

    There is no established national standard for rib fracture management. A clinical practice guideline (CPG) for rib fractures, including monitoring of pulmonary function, early initiation of aggressive loco-regional analgesia, and early identification of deteriorating respiratory function, was implemented in 2013. The objective of the study was to evaluate the effect of the CPG on hospital length of stay. Hospital length of stay (LOS) was compared for adult patients admitted to the hospital with rib fracture(s) two years before and two years after CPG implementation. A separate analysis was done for the patients admitted to the intensive care unit (ICU). Over the 48-month study period, 571 patients met inclusion criteria for the study. Pre-CPG and CPG study groups were well matched with few differences. Multivariable regression did not demonstrate a difference in LOS (B = -0.838; P = 0.095) in the total study cohort. In the ICU cohort (n = 274), patients in the CPG group were older (57 vs 52 years; P = 0.023) and had more rib fractures (4 vs 3; P = 0.003). Multivariable regression identified a significant decrease in LOS for those patients admitted in the CPG period (B = -2.29; P = 0.019). Despite being significantly older with more rib fractures in the ICU cohort, patients admitted after implementation of the CPG had a significantly reduced LOS on multivariable analysis, reducing LOS by over two days. This structured intervention can limit narcotic usage, improve pulmonary function, and decrease LOS in the most injured patients with chest trauma.

  8. Thermal-hydraulic modeling of porous bed reactors

    International Nuclear Information System (INIS)

    Araj, K.J.; Nourbakhsh, H.P.

    1987-01-01

    Optimum design of nuclear reactor core requires an iterative approach between the thermal-hydraulic, neutronic and operational analysis. This paper concentrates on the thermal-hydraulic behavior of a hydrogen cooled, small particle bed reactor (PBR). The PBR core, modeled here, consists of a hexagonal array of fuel elements embedded in a moderator matrix. The fuel elements are annular packed beds of fuel particles held between two porous cylindrical frits. These particles, 500 to 600 μm in diameter, have a uranium carbide core, which is coated by two layers of graphite and an outer coating of zirconium carbide. Coolant flow, radially inward, from the cold frit through the packed bed and hot frit and axially out the channel, formed by the hot frit, to a common plenum. 5 refs., 1 fig., 2 tabs

  9. Investigation of the possibility to use a fine-mesh solver for resolving coupled neutronics and thermal-hydraulics

    International Nuclear Information System (INIS)

    Jareteg, K.; Vinai, P.; Demaziere, C.

    2013-01-01

    The development of a fine-mesh coupled neutronic/thermal-hydraulic solver is touched upon in this paper. The reported work investigates the feasibility of using finite volume techniques to discretize a set of conservation equations modeling neutron transport, fluid dynamics, and heat transfer within a single numerical tool. With the long-term objective of developing fine-mesh computing capabilities for a few selected fuel assemblies in a nuclear core, this preliminary study considers an infinite array of a single fuel assembly having a finite height. Thermal-hydraulic conditions close to the ones existing in PWRs are taken as a first test case. The neutronic modeling relies on the diffusion approximation in a multi-energy group formalism, with cross-sections pre-calculated and tabulated at the sub-pin level using a Monte Carlo technique. The thermal-hydraulics is based on the Navier-Stokes equations, complemented by an energy conservation equation. The non-linear coupling terms between the different conservation equations are fully resolved using classical iteration techniques. Early tests demonstrate that the numerical tool provides an unprecedented level of details of the coupled solution estimated within the same numerical tool and thus avoiding any external data transfer, using fully consistent models between the neutronics and the thermal-hydraulics. (authors)

  10. Onlay Rib Bone Graft in Elevation of Reconstructed Auricle: 17 Years of Experience

    Directory of Open Access Journals (Sweden)

    Taehoon Kim

    2013-05-01

    Full Text Available BackgroundA cartilage wedge block and covering flap are standard procedures for firm elevation of the ear in microtia correction. However, using costal cartilage for elevation of the reconstructed auricle can be insufficient, and the fixed cartilage wedge block may be absorbed or may slip out. Furthermore, elevating covering flaps is time-consuming and uses up fascia, a potential source of reconstruction material. Therefore, we propose an innovative method using autologous onlay rib bone graft for auricular elevation of microtia.MethodsFrom February 1995 to August 2012, 77 patients received a first stage operation with a rib cartilage framework graft. In the second stage operation, a small full thickness of rib bone was harvested through the previous donor scar. The bihalved rib bone was inserted into the subperiosteal pocket beneath the cartilage framework.ResultsThe follow-up time ranged from 1 month to 17 years, with a mean of 3 years. All of the patients sustained the elevation of their ears very well during the follow-up period. Donor site problems, except for hypertrophic scars, were not observed. Surgery-related complications, specifically skin necrosis, infection, or hematoma, occurred in 4 cases.ConclusionsOnlay rib bone graft used to elevate the reconstructed auricle is a more anatomically appropriate material than cartilage, due to the bone-to-bone contact between the bone graft and the temporal bone. Postoperative minor correction of the elevation degree is straightforward and the skin graft survives better. Therefore, reconstructed auricle elevation using onlay rib bone graft is a useful and valuable method.

  11. Evaluating the Relationship between Rib Fractures and the Probability of Abdominal Trauma; a Brief Report

    Directory of Open Access Journals (Sweden)

    Vahid Monsef Kasmaei

    2015-02-01

    Full Text Available Introduction: Trauma is one of the most important causes of death in patients under 40 years of age and the third common cause of death regardless of age. Rib cage damages are one of the major reasons for death in the early minutes post-trauma. Therefore, the present study aimed to evaluate the frequency of intra-abdominal injury in the patients with rib fracture who were referred to emergency department. Methods: This cross-sectional study included 60 patients with rib fractures who were admitted to the emergency department of Poorsina Hospital, Rasht, Iran, from March 2011 to March2012. A checklist was filled out for all the patients including age, sex, trauma mechanism, side and site of fracture, the number of broken ribs, the results of abdominal ultrasonography, the need for laparotomy and mortality. The collected data were classified based on descriptive statistics and analyzed using SPSS 16. Results: 60 patients with the mean age of 47.26±13.71 years were admitted to the emergency department during this time (81.7% male. The most common mechanism of trauma was car accident [22(36.7%]. Among these 60 patients, 71 rib fractures in 3 levels of chest (upper, middle, lower were detected and 50 (83.3% in the same area. Mean number of fractured ribs was 2.85±2.2 (minimum: 1, maximum 10. In 3 (5% patients, fracture was on both sides. The results of abdominal ultrasonography in 7 (11.7% patients were positive. The number of fractured ribs (p=0.017 and the area of the fracture (p=0.048 showed a significant correlation with the presence of intra-abdominal free fluid. The fracture of more than 2 ribs directly correlated with the possibility of intra-abdominal hemorrhage (p<0.0001. Conclusion: Based on the results of this study, it seems that the number and area of the fractured ribs directly and significantly correlate with the probability of abdominal trauma based on the results of abdominal ultrasonography.

  12. Inlet Diameter and Flow Volume Effects on Separation and Energy Efficiency of Hydrocyclones

    Science.gov (United States)

    Erikli, Ş.; Olcay, A. B.

    2015-08-01

    This study investigates hydrocyclone performance of an oil injected screw compressor. Especially, the oil separation efficiency of a screw compressor plays a significant role for air quality and non-stop working hour of compressors has become an important issue when the efficiency in energy is considered. In this study, two separation efficiency parameters were selected to be hydrocyclone inlet diameter and flow volume height between oil reservoir surface and top of the hydrocyclone. Nine different cases were studied in which cyclone inlet diameter and flow volume height between oil reservoir surface and top were investigated in regards to separation and energy performance aspects and the effect of the parameters on the general performance appears to be causing powerful influence. Flow inside the hydrocyclone geometry was modelled by Reynolds Stress Model (RSM) and hydro particles were tracked by Discrete Phase Model (DPM). Besides, particle break up was modelled by the Taylor Analogy Breakup (TAB) model. The reversed vortex generation was observed at different planes. The upper limit of the inlet diameter of the cyclone yields the centrifugal force on particles to decrease while the flow becomes slower; and the larger diameter implies slower flow. On the contrary, the lower limit is increment in speed causes breakup problems that the particle diameters become smaller; consequently, it is harder to separate them from gas.

  13. Lidocaine patches reduce pain in trauma patients with rib fractures.

    Science.gov (United States)

    Zink, Karen A; Mayberry, John C; Peck, Ellen G; Schreiber, Martin A

    2011-04-01

    Rib fracture pain is notoriously difficult to manage. The lidocaine patch is effective in other pain scenarios with an excellent safety profile. This study assesses the efficacy of lidocaine patches for treating rib fracture pain. A prospectively gathered cohort of patients with rib fracture was retrospectively analyzed for use of lidocaine patches. Patients treated with lidocaine patches were matched to control subjects treated without patches. Subjective pain reports and narcotic use before and after patch placement, or equivalent time points for control subjects, were gathered from the chart. All patients underwent long-term follow-up, including a McGill Pain Questionnaire (MPQ). Twenty-nine patients with lidocaine patches (LP) and 29 matched control subjects (C) were analyzed. During the 24 hours before patch placement, pain scores and narcotic use were similar (LP 5.3, C 4.6, P = 0.19 and LP 51, C 32 mg morphine, P = 0.17). In the 24 hours after patch placement, LP patients had a greater decrease in pain scores (LP 1.2, C 0.0, P = 0.01) with no change in narcotic use (LP -8.4, C 0.5-mg change in morphine, P = 0.25). At 60 days, LP patients had a lower MPQ pain score (LP 7.7, C 12.2, P rib fracture pain. Lidocaine patches resulted in a sustained reduction in pain, outlasting the duration of therapy.

  14. Comparison of Computed Tomography and Chest Radiography in the Detection of Rib Fractures in Abused Infants

    Science.gov (United States)

    Wootton-Gorges, Sandra L.; Stein-Wexler, Rebecca; Walton, John W.; Rosas, Angela J.; Coulter, Kevin P.; Rogers, Kristen K.

    2008-01-01

    Purpose: Chest radiographs (CXR) are the standard method for evaluating rib fractures in abused infants. Computed tomography (CT) is a sensitive method to detect rib fractures. The purpose of this study was to compare CT and CXR in the evaluation of rib fractures in abused infants. Methods: This retrospective study included all 12 abused infants…

  15. MODERN DIAGNOSTIC AND THERAPEUTIC TECHNOLOGIES FOR THE CHEST TRAUMA ASSOCIATED WITH THE FALL FROM A HEIGHT IN THE REPUBLIC RESEARCH CENTRE OF EMERGENCY MEDICINE

    Directory of Open Access Journals (Sweden)

    A. M. Khadzhibayev

    2015-01-01

    Full Text Available BACKGROUND. The rate of the multisystem chest trauma and mortality in patients with catatrauma remains high.OBJECTIVE. To study the diagnosis and treatment of the multisystem chest trauma in patients associated with the fall from a height.MATERIAL AND METHODS. 243 patients (208 multisystem injuries and 35 isolated injuries with a chest trauma associated with the fall from a height were examined in the surgical department of Republic research centre of emergency medicine. We performed X-ray, CT and endosurgical examinations.RESULTS. Instrumental examination revealed pneumothorax and hydrothorax in 24.4% and 22.6% of victims respectively. The rib injuries were observed in 181 patients, sternum fractures in 8 victims and thoracic vertebrae fractures in 84 patients. The puncture and thoracocentesis of the pleural cavities were performed in 85 cases. The thoracoscopy was performed in 21 patients, the thoracotomy – in 15 patients, suturing of the lung – in 22 patients, coagulation – in 15 patients, external plate fixation of multiple injured ribs – in 10 patients. The mortality rate was 21.4%.CONCLuSION. The specifics of the multisystem chest trauma associated with the fall from a height is the development of hemothorax and pneumothorax. Thoracocentesis and videothoracoscopy allow to diagnose and stop the hemorrhage properly, to restore the lung rupture and perform the thoracotomy in severe cases, as well as reduce of complications frequency and mortality rate. 

  16. Preliminary study of the thermo-hydraulic behaviour of the binary breeder reactor

    International Nuclear Information System (INIS)

    Silveira Luz, M. da; Ferreira, W.J.

    1984-06-01

    Continuing the development of the Binary Breeder Reactor, its physical configuration and the advantages of differents types of spacers are analysed. In order to simulate the thermo-hydraulic behaviour and obtain data for a preliminary evaluation of the core geometry, the COBRA III C code was used to study the effects of the lenght and diameter of the fuel element, the coolant inlet temperature, the system pressure, helicoidal pitch and the pitch to diameter ratio. (Author) [pt

  17. Pain as an indication for rib fixation: a bi-institutional pilot study.

    Science.gov (United States)

    de Moya, Marc; Bramos, Thanos; Agarwal, Suresh; Fikry, Karim; Janjua, Sumbal; King, David R; Alam, Hasan B; Velmahos, George C; Burke, Peter; Tobler, William

    2011-12-01

    In trauma patients, open reduction and internal fixation of rib fractures remain controversial. We hypothesized that patients who have open reduction and internal fixation of rib fractures would experience less pain compared with controls and thus require fewer opiates. Further, we hypothesized that improved pain control would result in fewer pulmonary complications and decreased length of stay. This is a retrospective bi-institutional matched case-control study. Cases were matched 1:2 by age, injury severity Score, chest abbreviated injury severity score, head abbreviated injury severity score, pulmonary contusion score, and number of fractured ribs. The daily total doses of analgesic drugs were converted to equianalgesic intravenous morphine doses, and the primary outcome was inpatient narcotic administration. Sixteen patients between July 2005 and June 2009 underwent rib fixation in 5 ± 3 days after injury using an average of 3 (1-5) metallic plates. Morphine requirements decreased from 110 mg ± 98 mg preoperatively to 63 ± 57 mg postoperatively (p = 0.01). There were no significant differences between cases and controls in the mean morphine dose (79 ± 63 vs. 76 ± 55 mg, p = 0.65), hospital stay (18 ± 12 vs. 16 ± 11 days, p = 0.67), intensive care unit stay (9 ± 8 vs. 7 ± 10 days, p = 0.75), ventilation days (7 ± 8 vs. 6 ± 10, p = 0.44), and pneumonia rates (31% vs. 38%, p = 0.76). The need for analgesia was significantly reduced after rib fixation in patients with multiple rib fractures. However, no difference in outcomes was observed when these patients were compared with matched controls in this pilot study. Further study is required to investigate these preliminary findings.

  18. Reconstruction of iliac crest with rib to prevent donor site complications: A prospective study of 26 cases

    Directory of Open Access Journals (Sweden)

    Dave B

    2007-01-01

    Full Text Available Background: The tricortical bone graft from the iliac crest are used to reconstruct the post corpectomy spinal defects. The donor iliac area defect is large and may give rise to pain at donor site, instability of pelvis, fracture of ilium, donor site muscle herniation or abdominal content herniation. Rib removed during thoracotomy was used by us to reconstruct the iliac crest defect. Materials and Methods: Twenty-six patients who underwent thoracotomy for dorsal spine corpectomy or curettage for various spinal pathologies from June 2002 to May 2004 were included in the study. After adequate decompression the spine was reconstructed by tricortical bone graft from iliac crest and reconstruction of the iliac crest was done with the rib removed for exposure during thoracotomy. Results: The mean follow up was 15 months. All patients had good graft incorporation which was evaluated on the basis of local tenderness and radiographs. One patient had graft displacement. Conclusion: The reconstruction of iliac crest by rib is a simple and effective procedure to prevent donor site complications.

  19. Comparative study of methods to estimate hydraulic parameters in the hydraulically undisturbed Opalinus Clay (Switzerland)

    Energy Technology Data Exchange (ETDEWEB)

    Yu, C.; Matray, J.-M. [Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-Roses, (France); Yu, C.; Gonçalvès, J. [Aix Marseille Université UMR 6635 CEREGE Technopôle Environnement Arbois-Méditerranée Aix-en-Provence, Cedex 4 (France); and others

    2017-04-15

    The deep borehole (DB) experiment gave the opportunity to acquire hydraulic parameters in a hydraulically undisturbed zone of the Opalinus Clay at the Mont Terri rock laboratory (Switzerland). Three methods were used to estimate hydraulic conductivity and specific storage values of the Opalinus Clay formation and its bounding formations through the 248 m deep borehole BDB-1: application of a Poiseuille-type law involving petrophysical measurements, spectral analysis of pressure time series and in situ hydraulic tests. The hydraulic conductivity range in the Opalinus Clay given by the first method is 2 × 10{sup -14}-6 × 10{sup -13} m s{sup -1} for a cementation factor ranging between 2 and 3. These results show low vertical variability whereas in situ hydraulic tests suggest higher values up to 7 × 10{sup -12} m s{sup -1}. Core analysis provides economical estimates of the homogeneous matrix hydraulic properties but do not account for heterogeneities at larger scale such as potential tectonic conductive features. Specific storage values obtained by spectral analysis are consistent and in the order of 10{sup -6} m{sup -1}, while formulations using phase shift and gain between pore pressure signals were found to be inappropriate to evaluate hydraulic conductivity in the Opalinus Clay. The values obtained are globally in good agreement with the ones obtained previously at the rock laboratory. (authors)

  20. Pulmonary nodule registration in serial CT scans based on rib anatomy and nodule template matching

    International Nuclear Information System (INIS)

    Shi Jiazheng; Sahiner, Berkman; Chan, H.-P.; Hadjiiski, Lubomir; Zhou, C.; Cascade, Philip N.; Bogot, Naama; Kazerooni, Ella A.; Wu, Y.-T.; Wei, J.

    2007-01-01

    An automated method is being developed in order to identify corresponding nodules in serial thoracic CT scans for interval change analysis. The method uses the rib centerlines as the reference for initial nodule registration. A spatially adaptive rib segmentation method first locates the regions where the ribs join the spine, which define the starting locations for rib tracking. Each rib is tracked and locally segmented by expectation-maximization. The ribs are automatically labeled, and the centerlines are estimated using skeletonization. For a given nodule in the source scan, the closest three ribs are identified. A three-dimensional (3D) rigid affine transformation guided by simplex optimization aligns the centerlines of each of the three rib pairs in the source and target CT volumes. Automatically defined control points along the centerlines of the three ribs in the source scan and the registered ribs in the target scan are used to guide an initial registration using a second 3D rigid affine transformation. A search volume of interest (VOI) is then located in the target scan. Nodule candidate locations within the search VOI are identified as regions with high Hessian responses. The initial registration is refined by searching for the maximum cross-correlation between the nodule template from the source scan and the candidate locations. The method was evaluated on 48 CT scans from 20 patients. Experienced radiologists identified 101 pairs of corresponding nodules. Three metrics were used for performance evaluation. The first metric was the Euclidean distance between the nodule centers identified by the radiologist and the computer registration, the second metric was a volume overlap measure between the nodule VOIs identified by the radiologist and the computer registration, and the third metric was the hit rate, which measures the fraction of nodules whose centroid computed by the computer registration in the target scan falls within the VOI identified by the

  1. Successful management of threatened aortic rupture late after rib fracture caused by blunt chest trauma.

    Science.gov (United States)

    Morimoto, Yoshihisa; Sugimoto, Takaki; Sakahira, Hideki; Matsuoka, Hidehito; Yoshioka, Yuki; Arase, Hiroki

    2014-05-01

    A 62-year-old man was crushed in a car accident and diagnosed with a fractured left ninth rib, pulmonary and heart contusion, hemopneumothorax, and descending aortic injury based on a computed tomography scan. He underwent chest tube drainage and was intubated for mechanical ventilation because a bone fragment of the ninth rib threatened to penetrate the descending aorta. On the second posttrauma day, computed tomography showed the bone fragment of the ninth rib approaching the descending aorta. He underwent graft replacement of the injured portion of the descending thoracic aorta, and we removed the fractured left ninth rib. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Rib fracture as a predictor of future fractures in young and older postmenopausal women: National Osteoporosis Risk Assessment (NORA)

    Science.gov (United States)

    Sajjan, S. G.; Barrett-Connor, E.; McHorney, C. A.; Miller, P. D.; Sen, S. S.; Siris, E.

    2013-01-01

    Summary A rib fracture history after age 45 was associated with a 5.4-fold increase in new rib fracture risk and a 2.4-fold increase in risk of any new clinical fracture in 155,031 postmenopausal women. A rib fracture history suggests osteoporosis and should be considered when evaluating patients for interventions to prevent fractures. Introduction Until recently, little attention was paid to rib fracture as an osteoporosis marker. Emerging evidence suggests rib fracture may be an osteoporotic fracture in men and women. We report the 5-year independent association between baseline rib fracture histories and self-reported future fractures by age (decade) in the NORA cohort (155,031 postmenopausal women, 50–99 years). Methods Participants reported fracture history and responded to follow-up surveys at years 1, 3, or 6. Women with a baseline rib fracture history without other fractures were compared with women with no fracture. Results At baseline, 4,758 (3.07%) women reported a rib fracture history without other fractures; 6,300 women reported 6,830 new clinical fractures, including wrist (2,271), rib (1,891), spine (1,136), hip (941), and forearm (591). Adjusted relative risk (ARR) values (95% confidence interval [CI]) for future fractures in women with rib fracture history versus women with no fracture history were 5.4 (4.8–6.1) at the rib, 2.1 (1.7–2.6) at the spine, and 1.4 (1.1–1.7) at the wrist, and not significant for forearm or hip fractures. Future fracture risk was at least doubled in women with a rib fracture history in all ages: ARR (95% CI) 3.4 (2.8–4.0) for ages 50–59, 2.5 (2.1–3.0) for ages 60–69, 2.0 (1.7–2.3) for ages 70–79, and 2.0 (1.6–2.6) for ages >80. Conclusions Rib fracture, the second most common clinical fracture in women (after wrist fracture), predicted future fractures of the rib, wrist, and spine at all ages. Women presenting with rib fractures should be evaluated for appropriate management to prevent future

  3. Glass molding of 3mm diameter aspheric plano-convex lens

    Science.gov (United States)

    Sung, Hayeong; Hue, Myung sang; Lee, Giljae; Ryu, Geunman; Kim, Dongguk; Yang, Suncheol

    2017-10-01

    The many industries and research fields have demands for small scale optical systems. To satisfy the demands, many studies are conducted and the miniaturization technologies have been developed. The optical lens is directly related to the optical systems and a key component for the miniaturization. So the aspheric surface which can replace multispherical lenses is applied to the optical lens. And fabrication methods to reduce the diameter of the lens have been developed. The glass molding pressing (GMP) process is an attractive method to fabricate aspheric lens among the lens manufacturing processes. Because the GMP process has advantages of productivity, repeatability and so on. In this study, a 3 mm diameter aspheric plano-convex lens was fabricated using the GMP process. The GMP process was divided into heating, pressing, annealing and cooling. And the process was conducted using a commercial glass molding machine. Mold tools consist of an upper and a lower mold insert, an inner and an outer guide. The aspheric and the flat surfaces of the mold inserts were coated with ta-C to prevent the sticking of the glass to the mold. The surfaces of molded lens were measured by white interferometry and surface profilometer. The height and the diameter were measured using optical microscopy. As results, the aspheric surface of the lens was 5.1187 nm in Ra and 0.242 um in Pt. And the flat surface was 2.6697 nm in Ra and 0.13 um in Pt. The height and the diameter were 1.935 mm and 3.002 mm respectively.

  4. A prospective single center study to assess the impact of surgical stabilization in patients with rib fracture.

    Science.gov (United States)

    Khandelwal, Gaurav; Mathur, R K; Shukla, Sumit; Maheshwari, Ankur

    2011-01-01

    To compare the intensity of pain and duration of return to normal activity in patients with rib fractures treated with surgical stabilization with plating versus conventional treatment modalities. This study was conducted over a 12 month period. Patients with rib fractures were assessed by numerical pain scale. Patients having pain scale less than 5 were excluded from study. Patients having pain scale of 5 or more than 5 were treated with conventional treatment for next 10 days. On 11th day patients were again assessed by numerical pain scale and patients having score less than 5 were excluded from study. Patients having pain scale of 5, 6, and 7 were treated with conventional treatment and patients having pain scale of 8, 9, and 10 were selected for operative management. Operative and control group were compared on basis of intensity of pain and duration of return to normal activity. Follow up was done on 5, 15, and 30 post operative day. There was less pain in operative group as compared to control group. Mean rib fracture pain in operative group was 9.15, 2.31, 1.12 as compared to 6.25, 5.96, 4.50 in control group on 5, 15 and 30 post operative days. Also there was early return to normal activity in operative group. Surgical stabilization of rib fracture, an underutilized intervention is better than conventional conservative management in terms of both, decrease in intensity of pain and early return to normal activity. Copyright © 2011 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  5. Ribbing disease: radiographic and biochemical characterization, lack of response to pamidronate

    Energy Technology Data Exchange (ETDEWEB)

    Ziran, Navid [Department of Orthopedic Surgery, University of Rochester, Rochester, New York (United States); Hill, Suvimol [Department of Radiology, Warren Grant Magnuson Clinical Center, National Institutes of Health, Bethesda, Maryland (United States); Wright, Mary E.; Kovacs, Joseph [Department of Critical Care Medicine, Warren Grant Magnuson Clinical Center, National Institutes of Health, Bethesda, Maryland (United States); Robey, Pamela Gehron [Craniofacial and Skeletal Diseases Branch, National Institutes of Dental and Craniofacial Research, National Institutes of Health, Bethesda, Maryland (United States); Wientroub, Shlomo [Department of Pediatric Orthopedic Surgery, Dana Children' s Hospital, Tel-Aviv Medical Center, Tel-Aviv (Israel); Collins, Michael T. [Craniofacial and Skeletal Diseases Branch, National Institutes of Dental and Craniofacial Research, National Institutes of Health, Bethesda, Maryland (United States); CSDB/NIDCR/NIH, Building 30 Room 228, MSC 4320, Bethesda, MD 20892-4320 (United States)

    2002-12-01

    Ribbing disease is a rare form of sclerosing dysplasia characterized by benign endosteal and periosteal bone growth confined to the diaphyses of the long bones, usually the tibiae and femora. The onset is usually after puberty and the most common presentation is pain that is usually self-limited, but may progress. The etiology and optimal treatment for the disease are unknown. We present the case of a 39-year-old Hispanic man with clinical and radiological manifestations of Ribbing disease. Radiographs and CT imaging demonstrated typical cortical thickening in the mid-diaphyses of the tibiae bilaterally that correlated with intense tracer uptake on {sup 99m}Tc-MDP bone scans. MRI demonstrated cortical thickening and abnormal marrow signal consistent with marrow edema. Bone marrow edema may explain the pain frequently associated with the disease. Multiple serum and urine markers of bone metabolism were within normal limits. In an effort to ameliorate pain, the patient was treated with the bisphosphonate, pamidronate. In spite of treatment, pain increased, requiring additional and larger doses of analgesics. Serial radiographs, CT, bone scans, and MRI all demonstrated disease progression with pamidronate treatment. In this report we present for the first time the finding of bone marrow edema with MRI as well as disease progression during intravenous pamidronate treatment. (orig.)

  6. Ribbing disease: radiographic and biochemical characterization, lack of response to pamidronate

    International Nuclear Information System (INIS)

    Ziran, Navid; Hill, Suvimol; Wright, Mary E.; Kovacs, Joseph; Robey, Pamela Gehron; Wientroub, Shlomo; Collins, Michael T.

    2002-01-01

    Ribbing disease is a rare form of sclerosing dysplasia characterized by benign endosteal and periosteal bone growth confined to the diaphyses of the long bones, usually the tibiae and femora. The onset is usually after puberty and the most common presentation is pain that is usually self-limited, but may progress. The etiology and optimal treatment for the disease are unknown. We present the case of a 39-year-old Hispanic man with clinical and radiological manifestations of Ribbing disease. Radiographs and CT imaging demonstrated typical cortical thickening in the mid-diaphyses of the tibiae bilaterally that correlated with intense tracer uptake on 99m Tc-MDP bone scans. MRI demonstrated cortical thickening and abnormal marrow signal consistent with marrow edema. Bone marrow edema may explain the pain frequently associated with the disease. Multiple serum and urine markers of bone metabolism were within normal limits. In an effort to ameliorate pain, the patient was treated with the bisphosphonate, pamidronate. In spite of treatment, pain increased, requiring additional and larger doses of analgesics. Serial radiographs, CT, bone scans, and MRI all demonstrated disease progression with pamidronate treatment. In this report we present for the first time the finding of bone marrow edema with MRI as well as disease progression during intravenous pamidronate treatment. (orig.)

  7. Diagnosis and treatment of rib fracture during spontaneous vaginal delivery

    Directory of Open Access Journals (Sweden)

    Jovanović Nebojša

    2013-01-01

    Full Text Available Introduction. Progress of labor in multiparous women usually is not accompanied with risk of any kind of birth trauma. Case Outline. We report a very rare case of rib fracture in a neonate during vaginal delivery in the 39/40 week of gestation. The expulsion started spontaneously without any manipulation from the obstetrician. Live male newborn was delivered 4650 g. in weight, 55 cm long, with head circumference of 39 cm, Apgar score 9. The child was immediately examined by the neonatologist. Crepitations were palpable over the left hemithorax, and auscultatory on the left side inspiratory cracks. Finding was suspicious for rib fracture on the left side posteriorly and brachial plexus palsy, while other findings were normal. X­ray finding was inconclusive, but suspicious for fracture of the 4th, 5th, and 6th left rib posteriorly, without dislocation of bone fragments. There were no signs of pneumothorax. Dorsal position of the newborn was considered sufficient, accompanied with analgetics. X­ray was scheduled in a week because formation of the calus would be the only objective sign of previous rib fracture. On the control X­ray fracture lines were clearly visible on the 3rd, 4th, 5th, 6th and 7th rib posteriorly, without dislocation of bone fragments with initial calus formation. The child was discharged from hospital in good condition after two weeks, for further outpatient care. Conclusion. With timely diagnostics of this very rare intrapartal fracture, adequate treatment, dorsal position and close control of clinical condition of the newborn, serious and potentially life threatening complications can be avoided.

  8. Stress fractures of the ribs in elite competitive rowers: a report of nine cases

    Energy Technology Data Exchange (ETDEWEB)

    Dragoni, S. [Institute of Sport Medicine and Science of the Italian Olympic Committee, Department of Radiology, Rome (Italy); Giombini, A.; Ripani, M. [University of Motor Sciences, Department of Health, Rome (Italy); Di Cesare, A. [University of Rome ' ' La Sapienza' ' , Department of Physical Medicine and Rehabilitation, Rome (Italy); Magliani, G. [Medical Department of the Italian State Police, Rome (Italy)

    2007-10-15

    The objective was to report the clinical and imaging patterns of nine cases of stress fractures of the rib diagnosed in Italian Olympic rowers. Nine patients with stress fractures of the rib detected from 103 (8.7%) Italian team rowers competing between May 2000 and May 2006 were identified based on the database of a sports medicine institute. All athletes were male. They were aged between 17 and 31 years (mean: 24.4). Patient weight, fracture location, rowing side and imaging methods employed were noted. The diagnosis was made based on history, clinical examination and Tc-99m MDP bone scintigraphy. Eight of the 9 fractures were located anterolaterally between the fourth and ninth rib. In 1 of the 5 athletes with standard radiographs, a fracture line was visible and in 4 there was callus formation. In 2 athletes sonography was performed, which detected discontinuity of the rib surface and callus formation (1 case each). Stress fractures of the ribs are relatively common in competitive rowers. They are characterized by increasing lateral chest pain and typical scintigraphic, radiographic and sonographic findings. (orig.)

  9. Stress fractures of the ribs in elite competitive rowers: a report of nine cases

    International Nuclear Information System (INIS)

    Dragoni, S.; Giombini, A.; Ripani, M.; Di Cesare, A.; Magliani, G.

    2007-01-01

    The objective was to report the clinical and imaging patterns of nine cases of stress fractures of the rib diagnosed in Italian Olympic rowers. Nine patients with stress fractures of the rib detected from 103 (8.7%) Italian team rowers competing between May 2000 and May 2006 were identified based on the database of a sports medicine institute. All athletes were male. They were aged between 17 and 31 years (mean: 24.4). Patient weight, fracture location, rowing side and imaging methods employed were noted. The diagnosis was made based on history, clinical examination and Tc-99m MDP bone scintigraphy. Eight of the 9 fractures were located anterolaterally between the fourth and ninth rib. In 1 of the 5 athletes with standard radiographs, a fracture line was visible and in 4 there was callus formation. In 2 athletes sonography was performed, which detected discontinuity of the rib surface and callus formation (1 case each). Stress fractures of the ribs are relatively common in competitive rowers. They are characterized by increasing lateral chest pain and typical scintigraphic, radiographic and sonographic findings. (orig.)

  10. RibM from Streptomyces davawensis is a riboflavin/roseoflavin transporter and may be useful for the optimization of riboflavin production strains

    Science.gov (United States)

    2011-01-01

    Background The bacterium Bacillus subtilis, which is not a natural riboflavin overproducer, has been converted into an excellent production strain by classical mutagenesis and metabolic engineering. To our knowledge, the enhancement of riboflavin excretion from the cytoplasm of overproducing cells has not yet been considered as a target for (further) strain improvement. Here we evaluate the flavin transporter RibM from Streptomyces davawensis with respect to improvement of a riboflavin production strain. Results The gene ribM from S. davawensis, coding for a putative facilitator of riboflavin uptake, was codon optimized (ribMopt) for expression in B. subtilis. The gene ribMopt was functionally introduced into B. subtilis using the isopropyl-β-thiogalactopyranoside (IPTG)-inducible expression plasmid pHT01: Northern-blot analysis of total RNA from IPTG treated recombinant B. subtilis cells revealed a ribMopt specific transcript. Western blot analysis showed that the his6-tagged heterologous gene product RibM was present in the cytoplasmic membrane. Expression of ribM in Escherichia coli increased [14C]riboflavin uptake, which was not affected by the protonophore carbonyl cyanide m-chlorophenylhydrazone (CCCP). Expression of ribMopt supported growth of a B. subtilis ΔribB::Ermr ΔribU::Kanr double mutant deficient in riboflavin synthesis (ΔribB) and also deficient with respect to riboflavin uptake (ΔribU). Expression of ribMopt increased roseoflavin (a toxic riboflavin analog produced by S. davawensis) sensitivity of a B. subtilis ΔribU::Kanr strain. Riboflavin synthesis by a model riboflavin B. subtilis production strain overproducing RibM was increased significantly depending on the amount of the inducer IPTG. Conclusions The energy independent flavin facilitator RibM could in principle catalyze riboflavin export and thus may be useful to increase the riboflavin yield in a riboflavin production process using a recombinant RibM overproducing B. subtilis strain

  11. A novel and effective acupuncture modality as a complementary therapy to acute pain relief in inpatients with rib fractures.

    Science.gov (United States)

    Ho, Hsin-Yi; Chen, Chao-Wei; Li, Ming-Chieh; Hsu, Yu-Pao; Kang, Shih-Ching; Liu, Erh-Hao; Lee, Ko-Hung

    2014-01-01

    Pain control has been emphasized as a priority for both practitioners and inpatients with rib fractures, since analgesia could only offer limited relief from severe pain. A prospective and randomized controlled trial was conducted to analyze the efficacy and efficiency of acupuncture in acute pain relief for inpatients with rib fractures. A total of 58 inpatients were recruited and allocated to two groups, receiving identical doses of conventional oral analgesics as well as filiform needles as treatment and thumbtack intradermal (TI) needles placed upon the skin surface as a control, respectively, via novel acupuncture modality once daily for three consecutive days. The effect of pain relief was evaluated during activities that induce pain, and sustained maximal inspiration (SMI) lung volumes and sleep quality were assessed. The patients treated with filiform needles had more effective pain relief than those in the TI needle group during deep breathing, coughing, and turning over the body (p pain relief via acupuncture. The active evaluation could provide a more adaptive model for assessing pain intensity due to rib fractures. This novel acupuncture modality in which the needle insertion sites are corresponding to the pain spots can be a safe and viable therapy for relieving pain in inpatients with rib fractures.

  12. Free surface and hydraulic phenomena in a windowless symmetrical target

    Energy Technology Data Exchange (ETDEWEB)

    Cascone, R.; Salve, M. de; Malandrone, M.; Panella, B. [Politecnico di Torino, Dipt. di Energetica, Torino (Italy)

    2001-07-01

    In the windowless concept for the Accelerator Driven Systems target the liquid flow in the spallation region must be able to remove the volumetric thermal power due to the proton interactions with nuclei. In this paper the hydraulic phenomena of a basic symmetrical windowless target configuration with two concentric cylinders have been studied. The tests were aimed to measure the profile of the free surface of the flow and the liquid velocity field, by using water as hydraulic equivalent to lead-bismuth eutectic fluid. The test section consists of two concentric plexiglass pipes (inner cylinder diameter 200 mm, outer cylinder diameter 290 mm) where the water flows up in the annular region and flows down in the central region. The most important experimental parameters are the fluid level measured from the top edge of the inner cylinder and the imposed flow rate. The experiments have been carried out at room temperature in the following range: flow rate from 2.5 to 20 kg/s; fluid level at zero flow rate from -50 to 186 mm. (authors)

  13. STRESS FRACTURE OF THE FIRST RIB IN A HIGH SCHOOL WEIGHT LIFTER

    Directory of Open Access Journals (Sweden)

    Hiroyuki Fujioka

    2009-06-01

    Full Text Available A 17-year-old boy, who played a weight lifting in high school, sustained stress fracture of the first rib without any causes. We successfully treated first rib stress fracture with limitation of using the upper extremity and with using low-intensity pulsed ultrasound

  14. A semi-empirical model for predicting crown diameter of cedrela ...

    African Journals Online (AJOL)

    A semi-empirical model relating age and breast height has been developed to predict individual tree crown diameter for Cedrela odorata (L) plantation in the moist evergreen forest zones of Ghana. The model was based on field records of 269 trees, and could determine the crown cover dynamics, forecast time of canopy ...

  15. A novel and effective acupuncture modality as a complementary therapy to acute pain relief in inpatients with rib fractures

    OpenAIRE

    Hsin-Yi Ho; Chao-Wei Chen; Ming-Chieh Li; Yu-Pao Hsu; Shih-Ching Kang; Erh-Hao Liu; Ko-Hung Lee

    2014-01-01

    Background: Pain control has been emphasized as a priority for both practitioners and inpatients with rib fractures, since analgesia could only offer limited relief from severe pain. A prospective and randomized controlled trial was conducted to analyze the efficacy and efficiency of acupuncture in acute pain relief for inpatients with rib fractures. Methods: A total of 58 inpatients were recruited and allocated to two groups, receiving identical doses of conventional oral analgesics as we...

  16. Hydraulic and Wave Aspects of Novorossiysk Bora

    Science.gov (United States)

    Shestakova, Anna A.; Moiseenko, Konstantin B.; Toropov, Pavel A.

    2018-02-01

    Bora in Novorossiysk (seaport on the Black Sea coast of the Caucasus) is one of the strongest and most prominent downslope windstorms on the territory of Russia. In this paper, we evaluate the applicability of the hydraulic and wave hypotheses, which are widely used for downslope winds around the world, to Novorossiysk bora on the basis of observational data, reanalysis, and mesoscale numerical modeling with WRF-ARW. It is shown that mechanism of formation of Novorossiysk bora is essentially mixed, which is expressed in the simultaneous presence of gravity waves breaking and a hydraulic jump, as well as in the significant variability of the contribution of wave processes to the windstorm dynamics. Effectiveness of each mechanism depends on the elevated inversion intensity and mean state critical level height. Most favorable conditions for both mechanisms working together are moderate or weak inversion and high or absent critical level.

  17. Responses of Contrasting Tree Functional Types to Air Warming and Drought

    Directory of Open Access Journals (Sweden)

    Elisabet Martínez-Sancho

    2017-11-01

    Full Text Available Climate change-induced rise of air temperatures and the increase of extreme climatic events, such as droughts, will largely affect plant growth and hydraulics, leading to mortality events all over the globe. In this study, we investigated the growth and hydraulic responses of seedlings of contrasting functional types. Pinus sylvestris, Quercus spp. and Castanea sativa seedlings were grown in a common garden experiment under four treatments: control, air warming, drought and their combination during two consecutive growing periods. Height and diameter increments, stomatal conductance and stem water potentials were measured during both growing seasons. Additionally, hydraulic parameters such as xylem-specific native and maximum hydraulic conductivities, and native percentage of loss of conductivity were measured at the end of the entire experiment. Our results clearly pointed to different adaptive strategies of the studied species. Scots pine displayed a relatively isohydric behavior with a strict stomata control prohibiting native embolism whereas sweet chestnut and oak as relatively anisohydric species displayed an increased loss of native conductivity as a results of low water potentials. Seasonal timing of shoot and diameter growth also differed among functional types influencing drought impacts. Additionally, the possibility of embolism reversal seemed to be limited under the study conditions.

  18. Systemic administration of mesenchymal stem cells combined with parathyroid hormone therapy synergistically regenerates multiple rib fractures.

    Science.gov (United States)

    Cohn Yakubovich, Doron; Sheyn, Dmitriy; Bez, Maxim; Schary, Yeshai; Yalon, Eran; Sirhan, Afeef; Amira, May; Yaya, Alin; De Mel, Sandra; Da, Xiaoyu; Ben-David, Shiran; Tawackoli, Wafa; Ley, Eric J; Gazit, Dan; Gazit, Zulma; Pelled, Gadi

    2017-03-09

    A devastating condition that leads to trauma-related morbidity, multiple rib fractures, remain a serious unmet clinical need. Systemic administration of mesenchymal stem cells (MSCs) has been shown to regenerate various tissues. We hypothesized that parathyroid hormone (PTH) therapy would enhance MSC homing and differentiation, ultimately leading to bone formation that would bridge rib fractures. The combination of human MSCs (hMSCs) and a clinically relevant PTH dose was studied using immunosuppressed rats. Segmental defects were created in animals' fifth and sixth ribs. The rats were divided into four groups: a negative control group, in which animals received vehicle alone; the PTH-only group, in which animals received daily subcutaneous injections of 4 μg/kg teriparatide, a pharmaceutical derivative of PTH; the hMSC-only group, in which each animal received five injections of 2 × 10 6 hMSCs; and the hMSC + PTH group, in which animals received both treatments. Longitudinal in vivo monitoring of bone formation was performed biweekly using micro-computed tomography (μCT), followed by histological analysis. Fluorescently-dyed hMSCs were counted using confocal microscopy imaging of histological samples harvested 8 weeks after surgery. PTH significantly augmented the number of hMSCs that homed to the fracture site. Immunofluorescence of osteogenic markers, osteocalcin and bone sialoprotein, showed that PTH induced cell differentiation in both exogenously administered cells and resident cells. μCT scans revealed a significant increase in bone volume only in the hMSC + PTH group, beginning by the 4 th week after surgery. Eight weeks after surgery, 35% of ribs in the hMSC + PTH group had complete bone bridging, whereas there was complete bridging in only 6.25% of ribs (one rib) in the PTH-only group and in none of the ribs in the other groups. Based on the μCT scans, biomechanical analysis using the micro-finite element method demonstrated that

  19. Giant cell tumor of the rib: Two cases of F-18 FDG PET/CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hye Lim; Yoo, Le Ryung; Lee, Yeong Joo; Jung, Chan Kwon [Seoul St. Mary' s Hospital, College of MedicineThe Catholic University of Korea, Seoul (Korea, Republic of); Park, Sonya Young Ju [Molecular Imaging Program, Dept. of Radiology, Stanford Hospital and Clinics, Stanford (Korea, Republic of)

    2017-06-15

    We report two cases of giant cell tumor arising from the rib and their F-18 FDG PET/CT findings. The two patients complained of chest wall pain, and large lobulated soft tissue masses with intense FDG uptake were seen on F-18 FDG PET/CT. A malignant tumor such as osteosarcoma or chondrosarcoma was suspected due to the large size of the mass, bony destruction, and intense FDG uptake. En bloc resection was performed and final pathologic results revealed giant cell tumor of the rib. Giant cell tumor of the rib is very rare, and larger lesions with high FDG uptake can be misdiagnosed as an intrathoracic malignancy arising from the rib, pleura, or chest wall.

  20. Trauma patient adverse outcomes are independently associated with rib cage fracture burden and severity of lung, head, and abdominal injuries.

    Science.gov (United States)

    Dunham, C Michael; Hileman, Barbara M; Ransom, Kenneth J; Malik, Rema J

    2015-01-01

    We hypothesized that lung injury and rib cage fracture quantification would be associated with adverse outcomes. Consecutive admissions to a trauma center with Injury Severity Score ≥ 9, age 18-75, and blunt trauma. CT scans were reviewed to score rib and sternal fractures and lung infiltrates. Sternum and each anterior, lateral, and posterior rib fracture was scored 1 = non-displaced and 2 = displaced. Rib cage fracture score (RCFS) = total rib fracture score + sternal fracture score + thoracic spine Abbreviated Injury Score (AIS). Four lung regions (right upper/middle, right lower, left upper, and left lower lobes) were each scored for % of infiltrate: 0% = 0; ≤ 20% = 1, ≤ 50% = 2, > 50% = 3; total of 4 scores = lung infiltrate score (LIS). Of 599 patients, 193 (32%) had 854 rib fractures. Rib fracture patients had more abdominal injuries (p fractures (p = 0.0028) and death or need for mechanical ventilation ≥ 3 days (Death/Vdays ≥ 3) (p rib fracture patients, Glasgow Coma Score 3-12 or head AIS ≥ 2 occurred in 43%. A lung infiltrate or hemo/pneumothorax occurred in 55%. Thoracic spine injury occurred in 23%. RCFS was 6.3 ± 4.4 and Death/Vdays ≥ 3 occurred in 31%. Death/Vdays ≥ 3 rates correlated with RCFS values: 19% for 1-3; 24% for 4-6; 42% for 7-12 and 65% for ≥ 13 (p rib fracture score (p = 0.08) or number of fractured ribs (p = 0.80). Rib fracture patients have increased risk for truncal injuries and adverse outcomes. Adverse outcomes are independently associated with rib cage fracture burden. Severity of head, abdominal, and lung injuries also influence rib fracture outcomes.