WorldWideScience

Sample records for rhenium ions

  1. Rhenium Re

    International Nuclear Information System (INIS)

    Busev, A.I.; Tiptsova, V.G.; Ivanov, V.M.

    1978-01-01

    The basic methods for determining rhenium in various objects are presented. The gravimetric determination of rhenium is based on a quantitative precipitation of ReO 4 - ions with tetraphenylarsonium chloride. The determination is not hindered by tungstates and molybdates. The potentiometric determination of rhenium in alloys (>=0.5% Re) is based on perrhenate ion reduction to Re(4) with the titrated solution of the Cr(2) salt. Re(7) is titrated in a hot sulfuric acid solution in the presence of KJ. The relative error of the method is 1 to 3%. The photometric determination of rhenium is performed by the rhodamide method in molybdenum-and tungsten-containing alloys and catalytically, in rocks, after it has been separated in the form of sulfide. The extraction-photometric determination of rhenium is carried out with the aid of methyl violet (analysis of a stock with a high content of Mo, W, Ta, Nb, Ti ahd Zr) and thio-oxine (the determination of Re is hindered by Au, Pt, Pd, Ru, Os, Rh, Ir). Also described are methods for differential-spectrophotometric determination of Re with the aid of thiocarbamide, as well as with the aid of dimethylglyoxime in the presence of SnCl 2 in an acid medium when Re is determined in its alloys with niobium and hafnium. It takes 2 hours to analyze the Hf-Re alloy and 3 hours to analyze the Nb-Re alloy, the standard deviation being 0.005 at 30-50% Re and 0.027 to 0.019 at 10-50% Re

  2. Rhenium corrosion in chloride melts

    International Nuclear Information System (INIS)

    Stepanov, A.D.; Shkol'nikov, S.N.; Vetyukov, M.M.

    1989-01-01

    The results investigating rhenium corrosion in chloride melts containing sodium, potassium and chromium ions by a gravimetry potentials in argon atmosphere in a sealing quarth cell are described. Rhenium corrosion is shown to be rather considerable in melts containing CrCl 2 . The value of corrosion rate depending on temperature is determined

  3. Rhenium

    Science.gov (United States)

    John, David A.; Seal, Robert R.; Polyak, Désirée E.; Schulz, Klaus J.; DeYoung,, John H.; Seal, Robert R.; Bradley, Dwight C.

    2017-12-19

    Rhenium is one of the rarest elements in Earth’s continental crust; its estimated average crustal abundance is less than 1 part per billion. Rhenium is a metal that has an extremely high melting point and a heat-stable crystalline structure. More than 80 percent of the rhenium consumed in the world is used in high-temperature superalloys, especially those used to make turbine blades for jet aircraft engines. Rhenium’s other major application is in platinum-rhenium catalysts used in petroleum refining.Rhenium rarely occurs as a native element or as its own sulfide mineral; most rhenium is present as a substitute for molybdenum in molybdenite. Annual world mine production of rhenium is about 50 metric tons. Nearly all primary rhenium production (that is, rhenium produced by mining rather than through recycling) is as a byproduct of copper mining, and about 80 percent of the rhenium obtained through mining is recovered from the flue dust produced during the roasting of molybdenite concentrates from porphyry copper deposits. Molybdenite in porphyry copper deposits can contain hundreds to several thousand grams per metric ton of rhenium, although the estimated rhenium grades of these deposits range from less than 0.1 gram per metric ton to about 0.6 gram per metric ton.Continental-arc porphyry copper-(molybdenum-gold) deposits supply most of the world’s rhenium production and have large inferred rhenium resources. Porphyry copper mines in Chile account for about 55 percent of the world’s mine production of rhenium; rhenium is also recovered from porphyry copper deposits in the United States, Armenia, Kazakhstan, Mexico, Peru, Russia, and Uzbekistan. Sediment-hosted strata-bound copper deposits in Kazakhstan (of the sandstone type) and in Poland (of the reduced-facies, or Kupferschiefer, type) account for most other rhenium produced by mining. These types of deposits also have large amounts of identified rhenium resources. The future supply of rhenium is likely

  4. In-situ field-ion microscope study of the recovery behavior of heavy metal ion-irradiated tungsten, tungsten (rhenium) alloys and molybdenum

    International Nuclear Information System (INIS)

    Nielsen, C.H.

    1977-06-01

    Three field ion microscope (FIM) experiments were carried out to study the annealing behavior of heavy ion irradiated tungsten, tungsten (rhenium) alloys and molybdenum. The first experiment dealt with the stage I long-range migration of tungsten self interstitial atoms (SIAs) in high purity tungsten of resistivity ratio, R = 24,000 (R = rho 300 /rho 4 . 2 , where rho 300 and rho 4 . 2 are the room temperature and 0 0 C resistivities). The FIM specimens were irradiated in situ at 18 K with 30 keV W + ions to an average dose of 5 x 10 12 ions cm -2 and subsequently examined by the pulsed-field evaporation technique. The second experiment dealt with the phenomenon of impurity atom trapping of SIAs during long-range migration. It was shown that rhenium atoms in a tungsten matrix tend to capture tungsten SIAs and remain bound up to temperatures as high as 390 K. The final experiment was concerned with the low temperature annealing kinetics of irradiated molybdenum. High purity molybdenum of resistivity ratio R = 5700 was irradiated at 10 K with 30 keV Mo + ions to a dose of approximately 5 x 10 12 ions cm -2 . The results indicated that the electric field has only a minimal effect on the SIA annealing kinetics. This tends to strengthen the contention that the molybdenum SIA becomes mobile at 32 K

  5. Mechanical properties of tungsten following rhenium ion and helium plasma exposure

    Directory of Open Access Journals (Sweden)

    C.S. Corr

    2017-08-01

    Full Text Available Mechanical properties of Tungsten (W samples irradiated with 2 MeV Rhenium (Re ions and helium (He plasma were investigated using nanoindentation. It was found that there was an increase in hardness for all samples following separate irradiation with both Re ion and He plasma. A slight increase in hardness was obtained for combined exposures. A comparable increase in hardness was observed for a pure He plasma with a sample temperature of 473 K and 1273 K. Optical interferometry was employed to compare surface modification of the samples. Grazing incidence small angle x-ray scattering confirmed He nano-bubble formation of approximately 1 nm diameter in the higher temperature sample, which was not observed with samples at the lower temperatures.

  6. Electrodialysis separation of rhenium from silicon

    International Nuclear Information System (INIS)

    Prasolova, O.D.; Borisova, L.V.; Ermakov, A.N.

    1989-01-01

    A method of separation of ruthenium from silicon by electrodialysis with heterogenuos ion-exchange membranes is developed. The effeciency of purification of rhenium from silicon depending on the number of dialyzer chambers, temperature and pH value of the dialyzate is studed. It is found that an addditional fourth chamber between the middle and anolytic ones causes the purification coefficient increase 50 times. It is necessary to cool the dialyzate in order to reduce silicon migration into the anolyte and reverse diffusion of perrhenate-ion from the anolyte into the dialyzate. The optimal pH value of diaizate is 5.5-6. The method developed has been used for separating rhenium from industrial solution of lead production with complex composition

  7. Effect of rhenium addition on tungsten fuzz formation in helium plasmas

    NARCIS (Netherlands)

    Khan, A.; De Temmerman, G.; Morgan, T. W.; M. B. Ward,

    2016-01-01

    The effect of the addition of rhenium to tungsten on the formation of a nanostructure referred to as ‘fuzz’ when exposed to helium plasmas at fusion relevant ion fluxes was investigated in the Magnum and Pilot PSI devices at the FOM Institute DIFFER. The effect rhenium had on fuzz growth was seen to

  8. Effect of rhenium addition on tungsten fuzz formation in helium plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Aneeqa, E-mail: aneeqa.khan-3@postgrad.manchester.ac.uk [School of Mechanical, Aerospace and Civil Engineering, The University of Manchester, M13 9PL (United Kingdom); De Temmerman, Gregory [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046 - 13067 St Paul Lez Durance Cedex (France); Morgan, Thomas W. [FOM Institute DIFFER – Dutch Institute for Fundamental Energy Research, Partner in the Trilateral Euregio Cluster, Eindhoven (Netherlands); Ward, Michael B. [Institute for Materials Research, School of Chemical Process Engineering, University of Leeds, Leeds, LS2 9JT (United Kingdom)

    2016-06-15

    The effect of the addition of rhenium to tungsten on the formation of a nanostructure referred to as ‘fuzz’ when exposed to helium plasmas at fusion relevant ion fluxes was investigated in the Magnum and Pilot PSI devices at the FOM Institute DIFFER. The effect rhenium had on fuzz growth was seen to be dependent on time, temperature and flux. Initial fuzz growth was seen to be highly dependent on grain orientation, with rhenium having little effect. Once the fuzz was fully developed, the effect of grain orientation disappeared and the rhenium had an inhibiting effect on growth. This could be beneficial for inhibiting fuzz growth in a future fusion reactor, where transmutation of tungsten to rhenium is expected. It also appears that erosion or annealing of the fuzz is limiting growth of fuzz at higher temperatures in the range of ∼1340 °C.

  9. Effect of rhenium addition on tungsten fuzz formation in helium plasmas

    International Nuclear Information System (INIS)

    Khan, Aneeqa; De Temmerman, Gregory; Morgan, Thomas W.; Ward, Michael B.

    2016-01-01

    The effect of the addition of rhenium to tungsten on the formation of a nanostructure referred to as ‘fuzz’ when exposed to helium plasmas at fusion relevant ion fluxes was investigated in the Magnum and Pilot PSI devices at the FOM Institute DIFFER. The effect rhenium had on fuzz growth was seen to be dependent on time, temperature and flux. Initial fuzz growth was seen to be highly dependent on grain orientation, with rhenium having little effect. Once the fuzz was fully developed, the effect of grain orientation disappeared and the rhenium had an inhibiting effect on growth. This could be beneficial for inhibiting fuzz growth in a future fusion reactor, where transmutation of tungsten to rhenium is expected. It also appears that erosion or annealing of the fuzz is limiting growth of fuzz at higher temperatures in the range of ∼1340 °C.

  10. Spherical rhenium metal powder

    International Nuclear Information System (INIS)

    Leonhardt, T.; Moore, N.; Hamister, M.

    2001-01-01

    The development of a high-density, spherical rhenium powder (SReP) possessing excellent flow characteristics has enabled the use of advanced processing techniques for the manufacture of rhenium components. The techniques that were investigated were vacuum plasma spraying (VPS), direct-hot isostatic pressing (D-HIP), and various other traditional powder metallurgy processing methods of forming rhenium powder into near-net shaped components. The principal disadvantages of standard rhenium metal powder (RMP) for advanced consolidation applications include: poor flow characteristics; high oxygen content; and low and varying packing densities. SReP will lower costs, reduce processing times, and improve yields when manufacturing powder metallurgy rhenium components. The results of the powder characterization of spherical rhenium powder and the consolidation of the SReP are further discussed. (author)

  11. Rhenium radioisotopes for therapeutic radiopharmaceutical development

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Beets, A.L.; Pinkert, J.; Kropp, J.; Lin, W.Y.; Wang, S.Y.

    2001-01-01

    Rhenium-186 and rhenium-188 represent two important radioisotopes which are of interest for a variety of therapeutic applications in oncology, nuclear medicine and interventional cardiology. Rhenium-186 is directly produced in a nuclear reactor and the 90 hour half-life allows distribution to distant sites. The relatively low specific activity of rhenium-186 produced in most reactors, however, permits use of phosphonates, but limits use for labelled peptides and antibodies. Rhenium-188 has a much shorter 16.9 hour half-life which makes distribution from direct reactor production difficult. However, rhenium-188 can be obtained carrier-free from a tungsten-188/rhenium-188 generator, which has a long useful shelf-life of several months which is cost-effective, especially for developing regions. In this paper we discuss the issues associated with the production of rhenium-186- and rhenium-188 and the development and use of various radiopharmaceuticals and devices labelled with these radioisotopes for bone pain palliation, endoradiotherapy of tumours by selective catheterization and tumour therapy using radiolabelled peptides and antibodies, radionuclide synovectomy and the new field of vascular radiation therapy. (author)

  12. Electrochemical behaviour of rhenium-graphite electrode

    International Nuclear Information System (INIS)

    Varypaev, V.N.; Krasikov, V.L.

    1980-01-01

    Electrochemical behaviour of combination electrode from graphite with electrodeposited thin coating of electrolytic rhenium is studied. Solution of 0.5 m NaCl+0.04 m AlCl 3 served as an electrolite. Polarization galvanostatic curves of hydrogen evolution upon electrodes with conditional rhenium thickness of 3.5 and 0.35 μm, 35 and 3.5 nm are obtained. Possibility of preparation of rhenium-graphite cathode with extremely low rhenium consume, electro-chemical properties of which are simu-lar to purely rhenium cathode is shown. Such electrode is characterized with stable in time low cathode potential of hydrogen evolution in chloride electrolyte and during cathode polarization it is not affected by corrosion

  13. Rhenium carbene complexes and their applications; Rhenium-Carben-Komplexe und ihre Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Hille, Claudia Heidi

    2016-01-25

    New pharmaceutically suitable metal complexes play an important role in the development of diagnostic and therapeutic agents for cancer treatment. One option concerning new radiopharmaceuticals, is the application of the rhenium isotopes {sup 186}Re and {sup 188}Re. Therefore, water soluble but at the same time stable complexes, which can be synthesized straightforward, are required. In this thesis, several synthetic pathways to such rhenium complexes bearing Nheterocyclic carbenes are presented and applicability tests of literature known complexes conducted. The selected target structures based on monocarbenes turned out to be inappropriate for use in radiopharmaceutical applications, due to their long reaction times and purification issues. Additionally, sterical and electronical effects of the carbene ligands concerning complex formation have been investigated. Possibilities of functionalization at different positions on the heterocycle as well as hydrophilic wingtips - to achieve a better stability in an aqueous media - have been examined to gain information about chemical and physical properties of the resulting complexes. Furthermore, experiments regarding the coordination of various biscarbene ligands, which provides besides the stable chelatisation additionally the possibility of varying the linking bridge, to rhenium(I/V) precursors, have been performed. Dioxo-bis-(1,1{sup '}-methylene-bis(3,3{sup '}-diisopropylimidazolium-2-ylidene)) rhenium(V )-hexafluorophosphate was synthesized via a transmetalation reaction of the corresponding silver carbene with ReOCl{sub 3}(PPh{sub 3}){sub 2} and silver hexafluorophosphate. This complex provided the basis for the first radiolabeled {sup 188}Rhenium NHC complex later on. An enhancement of the kinetic and thermodynamic stability of potential rhenium biscarbene complexes based on modifications concerning the length and character of the bridging moiety between the chelating NHC rings as well as the nature of

  14. Rhenium Rocket Manufacturing Technology

    Science.gov (United States)

    1997-01-01

    The NASA Lewis Research Center's On-Board Propulsion Branch has a research and technology program to develop high-temperature (2200 C), iridium-coated rhenium rocket chamber materials for radiation-cooled rockets in satellite propulsion systems. Although successful material demonstrations have gained much industry interest, acceptance of the technology has been hindered by a lack of demonstrated joining technologies and a sparse materials property data base. To alleviate these concerns, we fabricated rhenium to C-103 alloy joints by three methods: explosive bonding, diffusion bonding, and brazing. The joints were tested by simulating their incorporation into a structure by welding and by simulating high-temperature operation. Test results show that the shear strength of the joints degrades with welding and elevated temperature operation but that it is adequate for the application. Rhenium is known to form brittle intermetallics with a number of elements, and this phenomena is suspected to cause the strength degradation. Further bonding tests with a tantalum diffusion barrier between the rhenium and C-103 is planned to prevent the formation of brittle intermetallics.

  15. Near-Net Shape Powder Metallurgy Rhenium Thruster

    Science.gov (United States)

    Leonhardt, Todd; Hamister, Mark; Carlen, Jan C.; Biaglow, James; Reed, Brian

    2001-01-01

    This paper describes the development of a method to produce a near-net shape (NNS) powder metallurgy (PM) rhenium combustion chamber of the size 445 N (100 lbf) used in a high performance liquid apogee engine. These engines are used in low earth Orbit and geostationary orbit for satellite positioning systems. The developments in near-net shape powder metallurgy rhenium combustion chambers reported in this paper will reduce manufacturing cost of the rhenium chambers by 25 percent, and reduce the manufacturing time by 30 to 40 percent. The quantity of rhenium metal powder used to produce a rhenium chamber is reduced by approximately 70 percent and the subsequent reduction in machining schedule and costs is nearly 50 percent.

  16. Directed light fabrication of rhenium components

    Energy Technology Data Exchange (ETDEWEB)

    Milewski, J.O.; Thoma, D.J.; Lewis, G.K.

    1997-02-01

    Directed Light Fabrication (DLF) is a direct metal deposition process that fuses powder, delivered by gas into the focal zone of a high powered laser beam to form fully dense near-net shaped components. This is accomplished in one step without the use of molds, dies, forming, pressing, sintering or forging equipment. DLF is performed in a high purity inert environment free from the contaminants associated with conventional processing such as oxide and carbon pickup, lubricants, binding agents, cooling or cleaning agents. Applications using rhenium have historically been limited in part by its workability and cost. This study demonstrates the ability to fuse rhenium metal powder, using a DLF machine, into free standing rods and describes the associated parameter study. Microstructural comparisons between DLF deposited rhenium and commercial rhenium sheet product is performed. This research combined with existing DLF technology demonstrates the feasibility of forming complex rhenium, metal shapes directly from powder.

  17. Thermal conduction and linear expansion of sintered rhenium and tungsten-rhenium alloys at a temperature up to 1000 K

    International Nuclear Information System (INIS)

    Pozdnyak, N.Z.; Belyaev, R.A.; Vavilov, Yu.V.; Vinogradov, Yu.G.; Serykh, G.M.

    1978-01-01

    Preparation technology (by powder metallurgy methods) of sintered rhenium and tungsten-rhenium VR-5, VR-10, and VR-20 alloys is described. Thermal conduction of rhenium and VR-20 alloy has been measured in the temperature range from 300 to 1000 K. The value obtained turned out to be considerably less than those published elsewhere, this testifies to the great thermal contact resistance between the material grains. Also measured is the mean linear expansion coefficient for the mentioned above materials in the same temperature range. Linear expansion increases with rhenium content increase

  18. Rhenium-osmium geochemistry: method and applications

    International Nuclear Information System (INIS)

    Luck, J.M.

    1982-03-01

    Experimental methods for chemical separation and isotopic analysis of rhenium-osmium are described. Accurate determinations are obtained for a quantity ratio around 10 -6 -10 -7 g. Development as a geochemical tracer is examined. Study of rhenium-osmium in meteorites allows the determination of solar system chronology and age of the galaxy. Rhenium-osmium chronology in meteorites is improved and osmium isotopes are used as petrogenetic and geological tracers. Molybdenites are studied through 187 Re- 187 Os dating [fr

  19. Crystallochemistry of rhenium compounds with metal-metal bonds

    International Nuclear Information System (INIS)

    Koz'min, P.A.; Surazhskaya, M.D.

    1980-01-01

    A review is presented including a brief description of atomic structure of 59 coordination rhenium compounds with metal-metal bond. The most important bond lengths and valent angles are presented for each compound. The dependence of rhenium-rhenium bond length on its multiplicity is discussed and possible causes of deviations from this dependence (namely, axial ligand presence, steric repulsion of ligands) are considered. On the basis of qualitative comparison of electronegativity of ligands in dimer compounds with quarternary bond of rhenium-rhenium a supposition is made on the influence of formal charge of atomic group and summary electro-negativity of ligands on the possibility of the metal-metal bond formation

  20. Rhenium Nanochemistry for Catalyst Preparation

    Directory of Open Access Journals (Sweden)

    Vadim G. Kessler

    2012-08-01

    Full Text Available The review presents synthetic approaches to modern rhenium-based catalysts. Creation of an active center is considered as a process of obtaining a nanoparticle or a molecule, immobilized within a matrix of the substrate. Selective chemical routes to preparation of particles of rhenium alloys, rhenium oxides and the molecules of alkyltrioxorhenium, and their insertion into porous structure of zeolites, ordered mesoporous MCM matrices, anodic mesoporous alumina, and porous transition metal oxides are considered. Structure-property relationships are traced for these catalysts in relation to such processes as alkylation and isomerization, olefin metathesis, selective oxidation of olefins, methanol to formaldehyde conversion, etc.

  1. THERMIONIC EMISSION ENHANCEMENT FROM CESIUM COATED RHENIUM IN ELECTRIC FIELDS

    Energy Technology Data Exchange (ETDEWEB)

    de Steese, J. G.; Zollweg, R. J.

    1963-04-15

    The plasma-anode technique was used to observe anomalously high thermionic emission from a rhenium surface with small cesium coverage, where the work function of the composite surface is greater than the ionization potential of cesium. Data suggest that emission enhancement is caused by increased cesium coverage because of cesiumion trapping near the emitter surface under the influence of an ion-rich sheath. (auth)

  2. Thiocarbonyl complexes of rhenium. Pt. 1

    International Nuclear Information System (INIS)

    Abram, U.

    1993-01-01

    Novel rhenium complexes with terminal thiocarbonyl groups have been synthesized from ReCl 3 (Me 2 PhP) 3 and sodium diethyldithiocarbamate. mer-(Diethyldithiocarbamato)tris-(dimethylphenylphosphine)(thiocarbonyl)rhenium( I), mer-[Re(CS)(Me 2 PhP) 3 (Et 2 dtc)], and tris(diethyldithiocarbamato)(thiocarbonyl)rhenium(III), [Re(CS)(Et 2 dtc) 3 ] have been studied by infrared and NMR spectroscopy, mass spectrometry and X-ray diffraction. mer-[Re(CS)(Me 2 PhP) 3 (Et 2 dtc)] crystallizes orthorhombic in the space group P na 2 1 with a=1516.1(2), b=2189.8(2) and c=1035.6(1) pm. Structure solution and refinement converged at R=0.042. The coordination geometry is a distorted octahedron. The Re-C bond length is found to be 184(2) pm. [Re(CS)(Et 2 dtc) 3 ] crystallizes monoclinic in the space group P2 1 /c with a=962.2(6), b=1744.0(2), c=1537.4(6) pm and β=96.21(1) . The final R value is 0.028. In the monomeric complex the rhenium atom is seven-coordinate with an approximate pentagonal-bipyramidal coordination sphere and a rhenium-carbon distance of 181(1) pm. (orig.)

  3. Effect of rhenium irradiations on the mechanical properties of tungsten for nuclear fusion applications

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Aneeqa, E-mail: aneeqa.khan-3@postgrad.manchester.ac.uk [School of Mechanical, Aerospace and Civil Engineering, The University of Manchester, M13 9PL (United Kingdom); Elliman, Robert; Corr, Cormac [Research School of Physics and Engineering, The Australian National University, Canberra, ACT 2601 (Australia); Lim, Joven J.H.; Forrest, Andrew [School of Materials, The University of Manchester, M13 9PL (United Kingdom); Mummery, Paul [School of Mechanical, Aerospace and Civil Engineering, The University of Manchester, M13 9PL (United Kingdom); Evans, Llion M. [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom)

    2016-08-15

    As-received and annealed tungsten samples were irradiated at a temperature of 400 °C with Re and W ions to peak concentrations of 1600 appm (atomic parts per million) and damage levels of 40 dpa (displacements per atom). Mechanical properties were investigated using nanoindentation, and the orientation and depth dependence of irradiation damage was investigated using Electron Back Scatter Diffraction (EBSD). Following irradiation there was a 13% increase in hardness in the as received sheet and a 23% increase in the annealed material for both tungsten and rhenium irradiation. The difference between the tungsten and rhenium irradiated samples was negligible, suggesting that for the concentrations and damage levels employed, the presence of rhenium does not have a significant effect on the hardening mechanism. Energy dependent EBSD of annealed samples provided information about the depth distribution of the radiation damage in individual tungsten grains and confirmed that the radiation damage is orientation dependant.

  4. Near net shape of powder metallurgy rhenium parts

    International Nuclear Information System (INIS)

    Leonhardt, T.; Downs, J.

    2001-01-01

    In this paper, a description of the stages of processing necessary to produce a near-net shape (NNS) powder metallurgy (PM) rhenium component through the use of cold isostatic pressing (CIP) to form a complex shape will be explained. This method was primarily developed for the production of the 440 N and 490 N liquid apogee engine combustion chambers used in satellite positioning systems. The CIP to NNS process has been used in the manufacture and production of other rhenium aerospace components as well. Cold isostatic pressing (CIP) to a near net shape utilizing a one or two-part mandrel greatly reduces the quantity of rhenium required to produce the component, and also significantly reduces the number of secondary machining operations necessary to complete the manufacturing process. Further, the developments in near-net shape powder metallurgy rhenium manufacturing techniques have generated significant savings in the area of both time and budget. Overall, cost declined by as much as 35 % for the quantity of rhenium chambers, and manufacturing time was decreased by 30-40 %. The quantity of rhenium metal powder used to produce a rhenium chamber was reduced by approximately 70 %, with a subsequent reduction of nearly 50 % in secondary machining operation schedules. Thus, it is apparent that the overall savings provided by the production of near-net shape powder metallurgy rhenium components will be more than merely another aspect of any project involving high temperature applications, it will constitute significant benefit. (author)

  5. Development of industrial hydrogenating catalyst on rhenium base

    International Nuclear Information System (INIS)

    Chistyakova, G.A.; Bat', I.I.; Rebrova, V.V.

    1975-01-01

    Processes for forming rhenium catalysts on carbon carrier and their catalytic properties in nitrobenzene (NB) reduction were studied. Application of an ammonia preparation to the carbon surface produced impregnated carbon saturated at room temperature with a water solution of the ammonia preparation, taken in a volume equal to the volumetric capacity of the carbon. With one impregnation, 2% rhenium was taken up. Catalysts containing more than 5% rhenium were obtained by impregnating the carbon with heating and use of more concentrated solutions. Catalysts made in this way and dried at 100 0 C had the composition Re 2 OH/carbon/. The most active catalysts were those reduced at 200-250 0 C; higher temperatures, up to 300-500 0 C, decreased the activity. Study of the catalytic properties of the rhenium catalysts in a liquid phase reduction of NB showed that the specific activity of rhenium depends only slightly on the content of the active component in the catalyst and is close to the specific activity of palladium and considerably exceeds that of nickel. Study of the effect of the NB concentration and hydrogen pressure on the activity and stability of the 5% rhenium catalyst indicated that with NB concentrations from 50 to 10% the process takes place at an essentially constant rate; the order of the reaction was close to zero with an apparent activation energy of about 7000 cal/mole. At pressures of 15-200 atm the yield with the 5% catalyst was proportional to the hydrogen pressure. A big advantage of the rhenium catalysts in the reduction of NB is their high selectivity. With a higher activity than palladium and nickel catalysts, 5% rhenium catalyst produces a high operating capacity in a wide range of contact charges, which has considerable significance for industrial use in contact apparatus of the column type. Comparison of the costs of rhenium catalysts and granular carbon carrier with those of nickel, platinum, and palladium showed that 5% rhenium catalyst can

  6. Influence of the acid and basic properties of rhenium oxide supported on alumina catalyst on the catalytic performance in olefin metathesis; Influence des proprietes acido-basiques de l`oxyde de rhenium supporte sur les performances catalytiques en metathese des olefines

    Energy Technology Data Exchange (ETDEWEB)

    Nahama, F.

    1996-11-30

    The aim of this work is to study the influence of the acid-basic properties of rhenium oxide supported on alumina catalyst on the catalytic performance in olefin metathesis. The literature data indicate that the environment of the active site does possess acid properties. However, the nature of the acid sites is still matter of debate. Concerning the Re O{sub x} - Al{sub 2}O{sub 3} interactions, we have shown that perrhenate ions are electrostatically absorbed on alumina. The uptake of rhenium is favoured at acidic pH (below 4), and the absorbed rhenium is in equilibrium with rhenium in solution. The results of rhenium extraction by water strongly suggest that the surface compounds of the calcined Re{sub 2}O{sub 7}/Al{sub 2}O{sub 3} materials is aluminium perrhenate. Characterization of surface acidity of the catalyst by infrared spectroscopy reveals that the initiation of the metathesis reaction is governed essentially by Lewis acidity. This strongly supports the role of Lewis acidity, which is exalted by the increase of the rhenium content and the calcination temperature. Finally, we point out by ammonia adsorption-thermodesorption a band at 1320 cm{sup -1} characteristic of the Lewis acidity of aluminium perrhenate. This result is a second indication of the presence of aluminium perrhenate on the Re{sub 2}O{sub 7}/Al{sub 2}O{sub 3} catalyst surface. (author)

  7. First principles calculations of interstitial and lamellar rhenium nitrides

    Energy Technology Data Exchange (ETDEWEB)

    Soto, G., E-mail: gerardo@cnyn.unam.mx [Universidad Nacional Autonoma de Mexico, Centro de Nanociencias y Nanotecnologia, Km 107 Carretera Tijuana-Ensenada, Ensenada Baja California (Mexico); Tiznado, H.; Reyes, A.; Cruz, W. de la [Universidad Nacional Autonoma de Mexico, Centro de Nanociencias y Nanotecnologia, Km 107 Carretera Tijuana-Ensenada, Ensenada Baja California (Mexico)

    2012-02-15

    Highlights: Black-Right-Pointing-Pointer The possible structures of rhenium nitride as a function of composition are analyzed. Black-Right-Pointing-Pointer The alloying energy is favorable for rhenium nitride in lamellar arrangements. Black-Right-Pointing-Pointer The structures produced by magnetron sputtering are metastable variations. Black-Right-Pointing-Pointer The structures produced by high-pressure high-temperature are stable configurations. Black-Right-Pointing-Pointer The lamellar structures are a new category of interstitial dissolutions. - Abstract: We report here a systematic first principles study of two classes of variable-composition rhenium nitride: i, interstitial rhenium nitride as a solid solution and ii, rhenium nitride in lamellar structures. The compounds in class i are cubic and hexagonal close-packed rhenium phases, with nitrogen in the octahedral and tetrahedral interstices of the metal, and they are formed without changes to the structure, except for slight distortions of the unit cells. In the compounds in class ii, by contrast, the nitrogen inclusion provokes stacking faults in the parent metal structure. These faults create trigonal-prismatic sites where the nitrogen residence is energetically favored. This second class of compounds produces lamellar structures, where the nitrogen lamellas are inserted among multiple rhenium layers. The Re{sub 3}N and Re{sub 2}N phases produced recently by high-temperature and high-pressure synthesis belong to this class. The ratio of the nitrogen layers to the rhenium layers is given by the composition. While the first principle calculations point to higher stability for the lamellar structures as opposed to the interstitial phases, the experimental evidence presented here demonstrates that the interstitial classes are synthesizable by plasma methods. We conclude that rhenium nitrides possess polymorphism and that the two-dimensional lamellar structures might represent an emerging class of materials

  8. First principles calculations of interstitial and lamellar rhenium nitrides

    International Nuclear Information System (INIS)

    Soto, G.; Tiznado, H.; Reyes, A.; Cruz, W. de la

    2012-01-01

    Highlights: ► The possible structures of rhenium nitride as a function of composition are analyzed. ► The alloying energy is favorable for rhenium nitride in lamellar arrangements. ► The structures produced by magnetron sputtering are metastable variations. ► The structures produced by high-pressure high-temperature are stable configurations. ► The lamellar structures are a new category of interstitial dissolutions. - Abstract: We report here a systematic first principles study of two classes of variable-composition rhenium nitride: i, interstitial rhenium nitride as a solid solution and ii, rhenium nitride in lamellar structures. The compounds in class i are cubic and hexagonal close-packed rhenium phases, with nitrogen in the octahedral and tetrahedral interstices of the metal, and they are formed without changes to the structure, except for slight distortions of the unit cells. In the compounds in class ii, by contrast, the nitrogen inclusion provokes stacking faults in the parent metal structure. These faults create trigonal-prismatic sites where the nitrogen residence is energetically favored. This second class of compounds produces lamellar structures, where the nitrogen lamellas are inserted among multiple rhenium layers. The Re 3 N and Re 2 N phases produced recently by high-temperature and high-pressure synthesis belong to this class. The ratio of the nitrogen layers to the rhenium layers is given by the composition. While the first principle calculations point to higher stability for the lamellar structures as opposed to the interstitial phases, the experimental evidence presented here demonstrates that the interstitial classes are synthesizable by plasma methods. We conclude that rhenium nitrides possess polymorphism and that the two-dimensional lamellar structures might represent an emerging class of materials within binary nitride chemistry.

  9. Concentration of rhenium from dilute sodium chloride solutions

    Directory of Open Access Journals (Sweden)

    DRAGOLJUB M. LUKIC

    2008-03-01

    Full Text Available The conditions for the desorption of rhenium from the anion exchange resin Dowex 1-x8 by HNO3, HCl, H2SO4 and NaOH were determined. The solution (5.0´10-3 mol dm-3 Re in 0.15 mol dm-3 NaCl was passed through a column containing 0.10 g of the resin. The total sorbed amount of rhenium was 0.20 g/g of the resin. It was then eluted by the corresponding eluent in the concentration range up to about 3.0 mol dm-3. The highest elution efficiency and the most favourable elution profile were found with 3.0 mol dm-3 HNO3. Over 77 % of the sorbed rhenium was found in the first 5 ml of the eluate. Practically all the rhenium was recovered with 20 ml of the acid. Under the given experimental conditions, HCl and H2SO4 were less favourable while NaOH was not applicable, due to very low efficiency of rhenium elution.

  10. Ambient aging of rhenium filaments used in thermal ionization mass spectrometry: Growth of oxo-rhenium crystallites and anti-aging strategies

    Directory of Open Access Journals (Sweden)

    Joseph M. Mannion

    2017-01-01

    Full Text Available Degassing is a common preparation technique for rhenium filaments used for thermal ionization mass spectrometric analysis of actinides, including plutonium. Although optimization studies regarding degassing conditions have been reported, little work has been done to characterize filament aging after degassing. In this study, the effects of filament aging after degassing were explored to determine a “shelf-life” for degassed rhenium filaments, and methods to limit filament aging were investigated. Zone-refined rhenium filaments were degassed by resistance heating under high vacuum before exposure to ambient atmosphere for up to 2 months. After degassing the nucleation and preferential growth of oxo-rhenium crystallites on the surface of polycrystalline rhenium filaments was observed by atomic force microscopy and scanning electron microscopy (SEM. Compositional analysis of the crystallites was conducted using SEM-Raman spectroscopy and SEM energy dispersive X-ray spectroscopy, and grain orientation at the metal surface was investigated by electron back-scatter diffraction mapping. Spectra collected by SEM-Raman suggest crystallites are composed primarily of perrhenic acid. The relative extent of growth and crystallite morphology were found to be grain dependent and affected by the dissolution of carbon into filaments during annealing (often referred to as carbonization or carburization. Crystallites were observed to nucleate in region specific modes and grow over time through transfer of material from the surface. Factors most likely to affect the rates of crystallite growth include rhenium substrate properties such as grain size, orientation, levels of dissolved carbon, and relative abundance of defect sites; as well as environmental factors such as length of exposure to oxygen and relative humidity. Thin (∼180 nm hydrophobic films of poly(vinylbenzyl chloride were found to slow the growth of oxo-rhenium crystallites on the filament

  11. Linkable thiocarbamoylbenzamidines as ligands for bioconjugation of Rhenium and Technetium; Kopplungsfaehige Thiocarbamoylbenzamidine als Liganden zur Biokonjugation von Rhenium und Technetium

    Energy Technology Data Exchange (ETDEWEB)

    Castillo Gomez, Juan Daniel

    2015-04-27

    Bioconjugation reactions with Rhenium and Technetium are of high importance for the development of novel radiopharmaceuticals for nuclear medicine. In this thesis the possibilities for bioconjugation using linkable Thiocarmbamoylbenzamidines as ligands for the complexation of Rhenium and Technetium were examined.

  12. Electrodeposition of rhenium from chloride melts: Electrochemical nature, structure and applied aspects

    Directory of Open Access Journals (Sweden)

    Vinogradov-Zhabrov O.N.

    2003-01-01

    Full Text Available Processes involved in the electrodeposition of rhenium from chloride melts have been studied over the temperature interval from 680 to 970 0C at a cathodic current density of 5 to 250 mA/cm2. It has been found that rhenium is deposited in the form of continuous layers. In addition to that the growth of deposits as separate single-crystal needles has also been noticed. Continuous layers had axial growth textures. The crystallographic direction of the textures is due to electrolysis conditions, such as concentration of oxygen-containing impurities, temperature, melt composition and cathodic current density. When the concentration of oxygen-containing impurities in the melt decreased, electrolysis temperature increased, the average radius of the supporting electrolyte cations became smaller, or cathodic current density diminished, the direction of the growth textures was changing as follows: (1010 →(1120 →(101L →(0001 →(0001needles. The microhardness of the deposits in this series is 900 to 250 kg/mm2. The growth of deposits on textured rhenium substrates and single crystals having different orientations, including bent substrates, was studied. It has been found that the epitaxial growth is virtually unlimited in depth if the orientation of the substrate coincides with the growth texture under given conditions. If the substrate orientation deviated from the growth texture, the epitaxial growth was nearly absent. Kinetic parameters were measured using the galvanostatic method. The exchange current density was determined over the interval of (0.01-0.1 A/cm2 depending on the concentration of oxygen-containing impurities, cation composition, type of the surface and its condition. The parameter α⋅Z, which was estimated by two methods, was equal to 2.1-3.1. The diffusion coefficient of rhenium ions has been found to be 2.8 ⋅10 −5 cm2/s at 790 0C and 3.5 ⋅10 −5 cm2/s at 840 0C. Galvanoplastic production of rhenium products, such as

  13. The kinetics of anodic dissolution of rhenium in aqueous electrolyte solutions

    International Nuclear Information System (INIS)

    Atanasyants, A.G.; Kornienko, V.A.

    1986-01-01

    The kinetics of anodic rhenium dissolution was investigated by means of potentiodynamic and potentiostatic polarization curves recorded at temperature from 293 to 333 K in different media (NaOH, KOH, NaCl, NaBr, HCl, H 2 SO 4 ) using the rotating disc technique. It is shown that the kinetics of anodic rhenium dissolution and effective activation energy depend not only on the composition and pH value of the solutions but also on the structure of the dissolving rhenium surface. The investigation of the anodic behaviour of the rhenium monocrystal revealed the existence of anisotropy of the monocrystal electrochemical properties. The experimental results point to an important role of adsorption processes in anodic rhenium dissolution. Rhenium dissolution proceeds with formation of intermediate surface adsorption complexes between the metal and the components of the solution

  14. Thermophysical measurements on solid and liquid rhenium

    International Nuclear Information System (INIS)

    Pottlacher, G.; Jager, H.; Neger, T.

    1986-01-01

    A fast resistive heating technique was used to measure such thermophysical data of solid and liquid rhenium as enthalpy, specific heat, thermal volume expansion, and electrical resistivity. The measurements are performed with heating rates of slightly more than 10 9 K s -1 up to states of superheated liquid rhenium (7500 K)

  15. Effect of Temperature and Mole Ratio on the Synthesis Yield of Rhenium-Tetrofosmin

    Directory of Open Access Journals (Sweden)

    Widyastuti

    2015-08-01

    Full Text Available Technetium-99m (99mTc tetrofosmin is widely used in nuclear medicine as a diagnostic agent for myocardial perfusion and as a tumor imaging agent. As a parenteral preparation it requires an evaluation of its pharmacokinetics and stability in-vivo. Since 99mTc has a short half-life and is only available in very low concentrations, it is impossible to characterize its chemical properties and presence in the body. Due to this reason, only technetium-99 (T1/2 = 5 × 105 years, which is available in macro quantities, or natural rhenium can be used for this purpose. In this study rhenium-188 (188Re tetrofosmin will be synthesized and applied, because non-radioactive Re can be easily obtained. Synthesis and radiochemical purity analysis of carrier-added 188Re-tetrofosmin were carried out as a model to study the in-vivo stability of technetium-99m tetrofosmin. Rhenium-188 was used as a tracer to identify the formation of rhenium tetrofosmin. Rhenium gluconate was synthesized first prior to the formation of rhenium tetrofosmin. The quality of labeling for both rhenium gluconate and rhenium tetrofosmin was analyzed using paper- and thin-layer chromatography, respectively. Rhenium gluconate can be synthesized with high labeling yield within 1 hour, whereas rhenium tetrofosmin was synthesized both in room temperature and in an elevated temperature with various tetrofosmin-to-rhenium mole ratios.The results showed that heating at 95oC led to a higher yield of more than 90% within 30 minutes. Rhenium tetrofosmin could be produced in high radiochemical purity using an excess of tetrofosmin with mole ratio of 2000. It is concluded that rhenium tetrofosmin could be synthesized through the formation of rhenium gluconate, and a higher yield could be obtained in a shorter time by heating process.

  16. Determination of rhenium in geologic samples of sandstone-type uranium deposit

    International Nuclear Information System (INIS)

    Li Yanan; Wang Xiuqin; Yin Jinshuang

    1997-01-01

    The thiourea colorimetry method suitable for the determination of samples with rhenium content higher than 5 μg/g is described. The method is characterized by many advantages: stability of analytical results, simplicity and cheapness of reagent, and wide range of analysed samples. The catalytic colorimetry is also applied to determine trace rhenium meeting the demand for comprehensive appraisal of prospecting and exploration, recovery and utilization of rhenium. This method can also be applied to analyse rhenium of other samples

  17. Elementary steps of the catalytic oxidation of CO in a gas phase in the presence of rhenium cations with carbonyl and oxygen ligands: a comparison with heterogeneous catalysis

    International Nuclear Information System (INIS)

    Goncharov, V.B.; Fialko, E.F.; Shejnin, D.Eh.; Kikhtenko, A.V.

    1997-01-01

    Reactivity in a gaseous phase o rhenium (Re + ) and rhenium monocarbonyl (ReCO + ) in the reaction of CO oxidation in oxygen-containing reagents (NO, O 2 , H 2 O) is studied through the method of the ionic cyclotron resonance. It is shown that presence of carbonyl ligand essentially influences the ion reactivity. The effective channel of the metal monocarbonyl ions oxidation through molecular oxygen is found. Accounting for this stage makes of possible to explain the low-temperature activity of a number of oxide catalyzer Mo, W in the reaction of CO oxidation by molecular oxygen

  18. Work function of carburized rhenium

    International Nuclear Information System (INIS)

    Pallmer, P.G. Jr.; Gordon, R.L.; Dresser, M.J.

    1980-01-01

    Variations of the electronic work function of carburized rhenium foils containing approximately 5 at.% carbon have been observed using the contact potential difference technique. Surface work function was observed to vary between 5.25 and 4.1 eV, with the work function of pure rhenium taken as 5.0 eV. Decrease in work function has been ascribed to the formation of graphitic layers on the surface at temperatures below the temperature of saturated solubility. The high work function surface was observed with all carbon in solution and has been ascribed to the presence of amorphous carbon near the surface

  19. Accelerator Production and Separations for High Specific Activity Rhenium-186

    Energy Technology Data Exchange (ETDEWEB)

    Jurisson, Silvia S. [Univ. of Missouri, Columbia, MO (United States); Wilbur, D. Scott [Univ. of Washington, Seattle, WA (United States)

    2016-04-01

    Tungsten and osmium targets were evaluated for the production of high specific activity rhenium-186. Rhenium-186 has potential applications in radiotherapy for the treatment of a variety of diseases, including targeting with monoclonal antibodies and peptides. Methods were evaluated using tungsten metal, tungsten dioxide, tungsten disulfide and osmium disulfide. Separation of the rhenium-186 produced and recycling of the enriched tungsten-186 and osmium-189 enriched targets were developed.

  20. Electrocatalysis of the hydrogen evolution reaction by rhenium oxides electrodeposited by pulsed-current

    International Nuclear Information System (INIS)

    Vargas-Uscategui, Alejandro; Mosquera, Edgar; Chornik, Boris; Cifuentes, Luis

    2015-01-01

    Highlights: • Rhenium oxides were produced by means of pulsed current electrodeposition over ITO. • The electrocatalytic behavior of rhenium oxides electrodeposited over ITO was studied. • Electrodeposited rhenium oxides showed electrocatalytic behavior increasing the rate of the hydrogen evolution reaction. • The electrocatalysis behavior was explained considering the relative abundance of Re species on the surface of the electrodeposited material. - Abstract: Rhenium oxides are materials of interest for applications in the catalysis of reactions such as those occurring in fuel cells and photoelectrochemical cells. This research work was devoted to the production of rhenium oxide by means of pulsed current electrodeposition for the electrocatalysis of the hydrogen evolution reaction (HER). Rhenium oxides were electrodeposited over a transparent conductive oxide substrate (Indium Tin-doped Oxide – ITO) in an alkaline aqueous electrolyte. The electrodeposition process allowed the production of rhenium oxides islands (200–600 nm) with the presence of three oxidized rhenium species: Re"I"V associated to ReO_2, Re"V"I associated to ReO_3 and Re"V"I"I associated to H(ReO_4)H_2O. Electrodeposited rhenium oxides showed electrocatalytic behavior over the HER and an increase of one order of magnitude of the exchange current density was observed compared to the reaction taking place on the bare substrate. The electrocatalytic behavior varied with the morphology and relative abundance of oxidized rhenium species in the electrodeposits. Finally, two mechanisms of electrocatalysis were proposed to explain experimental results.

  1. Mass spectrometry of rhenium complexes: a comparative study by using LDI-MS, MALDI-MS, PESI-MS and ESI-MS.

    Science.gov (United States)

    Petroselli, Gabriela; Mandal, Mridul Kanti; Chen, Lee Chuin; Ruiz, Gustavo T; Wolcan, Ezequiel; Hiraoka, Kenzo; Nonami, Hiroshi; Erra-Balsells, Rosa

    2012-03-01

    A group of rhenium (I) complexes including in their structure ligands such as CF(3)SO(3)-, CH(3)CO(2)-, CO, 2,2'-bipyridine, dipyridil[3,2-a:2'3'-c]phenazine, naphthalene-2-carboxylate, anthracene-9-carboxylate, pyrene-1-carboxylate and 1,10-phenanthroline have been studied for the first time by mass spectrometry. The probe electrospray ionization (PESI) is a technique based on electrospray ionization (ESI) that generates electrospray from the tip of a solid metal needle. In this work, mass spectra for organometallic complexes obtained by PESI were compared with those obtained by classical ESI and high flow rate electrospray ionization assisted by corona discharge (HF-ESI-CD), an ideal method to avoid decomposition of the complexes and to induce their oxidation to yield intact molecular cation radicals in gas state [M](+·) and to produce their reduction yielding the gas species [M](-·). It was found that both techniques showed in general the intact molecular ions of the organometallics studied and provided additional structure characteristic diagnostic fragments. As the rhenium complexes studied in the present work showed strong absorption in the UV-visible region, particularly at 355 nm, laser desorption ionization (LDI) mass spectrometry experiments could be conducted. Although intact molecular ions could be detected in a few cases, LDI mass spectra showed diagnostic fragments for characterization of the complexes structure. Furthermore, matrix-assisted laser desorption ionization (MALDI) mass spectra were obtained. Nor-harmane, a compound with basic character, was used as matrix, and the intact molecular ions were detected in two examples, in negative ion mode as the [M](-·) species. Results obtained with 2-[(2E)-3-(4-tert-buthylphenyl)-2-methylprop-2-enylidene] malononitrile (DCTB) as matrix are also described. LDI experiments provided more information about the rhenium complex structures than did the MALDI ones. Copyright © 2012 John Wiley & Sons, Ltd.

  2. Rhenium: a rare metal critical in modern transportation

    Science.gov (United States)

    John, David A.

    2015-01-01

    Rhenium is a silvery-white, metallic element with an extremely high melting point (3,180 degrees Celsius) and a heat-stable crystalline structure, making it exceptionally resistant to heat and wear. Since the late 1980s, rhenium has been critical for superalloys used in turbine blades and in catalysts used to produce lead-free gasoline.

  3. Thermal decomposition of rhenium (5) complexes with 1,2,4-triazole

    International Nuclear Information System (INIS)

    Amindzhanov, A.A.; Gagieva, S.Ch.; Kotegov, K.V.

    1991-01-01

    Processes of thermal decomposition of rhenium (5) complexes with 1,2,4-triazole were studied. Thermolysis products were identified on the basis of data of the element analysis, IR spectra, conductometry and other methods. It is ascertained that at the first stage of thermolysis of hydroxyl-containing monomer complexes removal of water molecules occurs, and at the second one - dimerization process with formation of Re-O-Re group. It is shown that the nature of halide ion practically does not affect the temperature of the start of intensive thermal decomposition of the complexes

  4. Determination of rhenium in ores of complex composition by the kinetic method

    Energy Technology Data Exchange (ETDEWEB)

    Pavlova, L G; Gurkina, T V [Kazakhskij Gosudarstvennyj Univ., Alma-Ata (USSR); Tsentral' naya Lab. Yuzhno-Kazakhstanskogo Geologicheskogo Upravleniya, Alma-Ata (USSR))

    1979-09-01

    The kinetic rhenium determination method is proposed based on rhenium catalytic effect in the reaction of malachite green with thiourea. The accompanying elements, excluding molybdenum, do not interfere with the rhenium determination at their concentration of up to 0.1 M. The interfering influence of molybdenum can be eliminated by addition of tartaric acid to the solution up to the concentration of 0.1 M. This enables to determine rhenium in presence of 1000-fold quantity of molybdenum. The method is applicable for the analysis of complex copper-zinc sulphide ores.

  5. Neutron activation determination of rhenium in mineral raw materials of complex composition

    International Nuclear Information System (INIS)

    Shiryaeva, M.B.; Lyubimova, L.N.; Salmin, Yu.P.; Ryumina, K.N.; Tatarkin, M.A.

    1984-01-01

    The method of neutron-activation rhenium determination in mineral raw material of complex composition is developed, according to which easily hydrolized elements: scandium, iron, lanthanum, ytterbium, protactinium, hafnium and partially ruthenium and osmium are isolated in the form of hydroxides after smelting of a sample, which has been previously irradiated in nuclear reactor (thermal neutron flux 1.2x10 13 n/cm 2 xs for 22 hr) with sodium peroxide and leaching of the melt by water. To separate Re from other interfering elements extraction of perrhenate-ion by methylethylketone from alkali solution is used. Interfering effect of gold is eliminated by its extraction with TBP 30% solution in toluence or benzene from 1 M HNO 3 . Activity of rhenium preparations, singled out from samples of comparison, is measured, using multichannel γ-spectrometer with Ge(Li)-coaxial detector of high resolution (approximately 2.0-2.2 keV over the line 122 keV 5+ Co). Relative standard deviation in Re content range 5x10 -7 -5x10 -2 % does not exceed 0.3

  6. Nipponium, the element ascribable to rhenium from the modern chemical viewpoint

    Energy Technology Data Exchange (ETDEWEB)

    Yoshihara, H.K. [Japan Isotope Data Inst., Sendai (Japan)

    1997-11-01

    Though the discovery of nipponium by Ogawa in 1908 was judged to be false and his work was forgotten for many years, the new element he believed to have found should be ascribed to rhenium (z = 75) by the following reasons: (1) the spectral line of 4882 A agrees well with the present data of rhenium, (2) recalculation of the atomic weight of the element supports the value in the neighbourhood of 185 which is very close to the present value 186.2 of rhenium, and (3) rhenium is actually present in Japanese molybdenite he studied. Therefore, it is concluded that his discovery of the `new` element was correct, but assignment of z = 43 was wrong. (orig.)

  7. Method of stably radiolabeling antibodies with technetium and rhenium

    International Nuclear Information System (INIS)

    Paik, C.H.; Reba, R.C.; Eckelman, W.C.

    1987-01-01

    A method is described for labeling antibodies or antibody fragments with radionuclides of technetium or rhenium to obtain stable labeling, comprising: reacting a reduced radioisotope of technetium or rhenium with an antibody or antibody fragment, or a diethylenetriaminepentaacetic acid conjugated antibody or antibody fragment, in the presence of free or carrier-bound diethylenetriaminepentaacetic acid (DTPA). The amount of DTPA is sufficient to substantially completely inhibit binding of the reduced technetium or rhenium to nonstable binding sites of the antibody or antibody fragment, or the DTPA-conjugated antibody or antibody fragment. The resultant stably labeled antibody or antibody fragment, or DTPA[conjugated antibody or antibody fragment is recovered

  8. Separation of Rhenium (VII) from Tungsten (VI)

    International Nuclear Information System (INIS)

    Vucina, J.; Lukic, D.; Stoiljkovic, M.; Milosevic, M.; Orlic, M.

    2004-01-01

    Examined were the conditions for an effective separation of tungsten (VI) and rhenium (VII) on alumina if the solution of 0.20 mol dm -3 NaCl, ph=2.6 is used as the aqueous phase. Under the given experimental conditions alumina was found to be much better adsorbent for tungsten than for rhenium. The breakthrough and saturation capacities of alumina at pH=2 are 24 and 78 mg W/g Al 2 O 3 , respectively. With the increase of pH these values decrease. So, at pH=6 they are only 4 and 13 mg W/g Al 2 O 3 respectively. The elution volume for rhenium for the given column dimensions and quantity of the adsorbent is about 16 ml. These results were confirmed by the experiments of the radiological separations. Tungsten-187 remains firmly bound to the alumina. The radionuclide purity of the eluted 186'188 Re at pH=2 is very high. (authors)

  9. Determination of rhenium in molybdenite by neutron-activation analysis.

    Science.gov (United States)

    Terada, K; Yoshimura, Y; Osaki, S; Kiba, T

    1967-01-01

    A neutron-activation method is described for the determination of rhenium in molybdenite. Radiochemical separation by a carrier technique was carried out very rapidly by means of successive liquid-liquid extraction processes. The recovery of rhenium, which was determined by a spectrophotometric method, was about 93%. About 10 samples could be analysed within 6 hr in parallel runs.

  10. A comparative study of electrochemical and optical properties of rhenium deposited on gold and platinum

    Energy Technology Data Exchange (ETDEWEB)

    Zerbino, Jorge O.; Castro Luna, Ana M.; Martins, M. E. [Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Buenos Aires (Argentina). Inst. de Investigaciones Fisico-Quimicas, Teoricas y Aplicadas (INIFTA)]. E-mail: mmartins@inifta.unlp.edu.ar; Zinola, Carlos F.; Mendez, Eduardo [Universidad de la Republica, Montevideo (Uruguay). Facultad de Ciencias. Lab. de Electroquimica Fundamental

    2002-08-01

    Rhenium-containing films were grown on gold and platinum after different potentiostatic and potentiodynamic polarizations in the - 0.20 V to 0.70 V range (vs rhe) in aqueous acid perrhenate. Experimental data were obtained using cyclic voltammetry and ellipsometry, from which the thickness and optical indices of the electrodeposited rhenium layer were calculated. Metallic rhenium deposition on gold takes place at potentials within the hydrogen evolution reaction. Rhenium oxide on platinum is formed in the hydrogen adatom potential domain, whereas metallic rhenium is deposited concurrently with the hydrogen adsorption and evolution reactions on the same metal. (author)

  11. A comparative study of electrochemical and optical properties of rhenium deposited on gold and platinum

    Directory of Open Access Journals (Sweden)

    Zerbino Jorge O.

    2002-01-01

    Full Text Available Rhenium-containing films were grown on gold and platinum after different potentiostatic and potentiodynamic polarizations in the - 0.20 V to 0.70 V range (vs rhe in aqueous acid perrhenate. Experimental data were obtained using cyclic voltammetry and ellipsometry, from which the thickness and optical indices of the electrodeposited rhenium layer were calculated. Metallic rhenium deposition on gold takes place at potentials within the hydrogen evolution reaction. Rhenium oxide on platinum is formed in the hydrogen adatom potential domain, whereas metallic rhenium is deposited concurrently with the hydrogen adsorption and evolution reactions on the same metal.

  12. New leads for fragment-based design of rhenium/technetium radiopharmaceutical agents.

    Science.gov (United States)

    Brink, Alice; Helliwell, John R

    2017-05-01

    Multiple possibilities for the coordination of fac -[Re(CO) 3 (H 2 O) 3 ] + to a protein have been determined and include binding to Asp, Glu, Arg and His amino-acid residues as well as to the C-terminal carboxylate in the vicinity of Leu and Pro. The large number of rhenium metal complex binding sites that have been identified on specific residues thereby allow increased target identification for the design of future radiopharmaceuticals. The core experimental concept involved the use of state-of-art tuneable synchrotron radiation at the Diamond Light Source to optimize the rhenium anomalous dispersion signal to a large value ( f '' of 12.1 electrons) at its L I absorption edge with a selected X-ray wavelength of 0.9763 Å. At the Cu  K α X-ray wavelength (1.5418 Å) the f '' for rhenium is 5.9 electrons. The expected peak-height increase owing to the optimization of the Re f '' was therefore 2.1. This X-ray wavelength tuning methodology thereby showed the lower occupancy rhenium binding sites as well as the occupancies of the higher occupancy rhenium binding sites.

  13. New leads for fragment-based design of rhenium/technetium radiopharmaceutical agents

    Directory of Open Access Journals (Sweden)

    Alice Brink

    2017-05-01

    Full Text Available Multiple possibilities for the coordination of fac-[Re(CO3(H2O3]+ to a protein have been determined and include binding to Asp, Glu, Arg and His amino-acid residues as well as to the C-terminal carboxylate in the vicinity of Leu and Pro. The large number of rhenium metal complex binding sites that have been identified on specific residues thereby allow increased target identification for the design of future radiopharmaceuticals. The core experimental concept involved the use of state-of-art tuneable synchrotron radiation at the Diamond Light Source to optimize the rhenium anomalous dispersion signal to a large value (f′′ of 12.1 electrons at its LI absorption edge with a selected X-ray wavelength of 0.9763 Å. At the Cu Kα X-ray wavelength (1.5418 Å the f′′ for rhenium is 5.9 electrons. The expected peak-height increase owing to the optimization of the Re f′′ was therefore 2.1. This X-ray wavelength tuning methodology thereby showed the lower occupancy rhenium binding sites as well as the occupancies of the higher occupancy rhenium binding sites.

  14. Monoclonal Antibodies Radiolabeling with Rhenium-188 for Radioimmunotherapy

    Science.gov (United States)

    Martini, Petra; Pasquali, Micol

    2017-01-01

    Rhenium-188, obtained from an alumina-based tungsten-188/rhenium-188 generator, is actually considered a useful candidate for labeling biomolecules such as antibodies, antibody fragments, peptides, and DNAs for radiotherapy. There is a widespread interest in the availability of labeling procedures that allow obtaining 188Re-labeled radiopharmaceuticals for various therapeutic applications, in particular for the rhenium attachment to tumor-specific monoclonal antibodies (Mo)Abs for immunotherapy. Different approaches have been developed in order to obtain 188Re-radioimmunoconjugates in high radiochemical purity starting from the generator eluted [188Re]ReO4−. The aim of this paper is to provide a short overview on 188Re-labeled (Mo)Abs, focusing in particular on the radiolabeling methods, quality control of radioimmunoconjugates, and their in vitro stability for radioimmunotherapy (RIT), with particular reference to the most important contributions published in literature in this topic. PMID:28951872

  15. Manufacture and properties of molybdenum-rhenium alloys

    International Nuclear Information System (INIS)

    Fischer, B.; Freund, D.

    2001-01-01

    It is necessary to measure strength and creep behavior to guarantee the safe and reliable usage of refractory alloys at extremely high temperatures. In the literature there is very little information available about the properties of Mo-Re alloys at temperatures higher than 1000 C. A special test facility has been designed and built for stress-rupture testing at very high temperatures (up to 3000 C) of refractory metals and alloys in inert atmospheres. - The stress-rupture strength as well as the creep behavior of molybdenum-rhenium alloys with rhenium contents between 41 and 51 wt.% have been determined at temperatures ranging from 1200 to 2000 C, and rupture times of up to 10 hours using this facility. Previous measurements of stress-rupture strength and creep behavior of pure rhenium have been compared with the measurement results of Mo-Re alloys. - The discussion of the values measured is based on metallographic test results and scanning electron microscopy (SEM) images of Mo-Re alloy samples after stress-rupture testing. (orig.) [de

  16. Synthesis, molecular structure and magnetic properties of a rhenium(IV) compound with catechol

    Science.gov (United States)

    Cuevas, A.; Geis, L.; Pintos, V.; Chiozzone, R.; Sanchíz, J.; Hummert, M.; Schumann, H.; Kremer, C.

    2009-03-01

    A novel Re(IV) complex containing catechol as ligand has been prepared and characterized. The crystal structure of (HNEt 3)(NBu 4)[ReCl 4(cat)]·H 2cat was determined. The rhenium ion presents a distorted octahedral geometry, being bonded to a bidentate catecholate group and four chloride anions. The magnetic properties of the complex were studied, a /2 D/ (the energy gap between ±3/2 and ±1/2 Kramers doublets) value of 190(10) cm -1. This is the largest /2 D/ value reported for Re(IV) up to now.

  17. Determination of rhenium in molybdenite by X-ray fluorescence: A combined chemical-spectrometric technique.

    Science.gov (United States)

    Solt, M W; Wahlberg, J S; Myers, A T

    1969-01-01

    Rhenium in molybdenite is separated from molybdenum by distillation of rhenium heptoxide from a perchloric-sulphuric acid mixture. It is concentrated by precipitation of the sulphide and then determined by X-ray fluorescence. From 3 to 1000 microg of rhenium can be measured with a precision generally within 2%. The procedure tolerates larger amounts of molybdenum than the usual colorimetric methods.

  18. Determination of rhenium in molybdenite by X-ray fluorescence. A combined chemical-spectrometric technique

    Science.gov (United States)

    Solt, M.W.; Wahlberg, J.S.; Myers, A.T.

    1969-01-01

    Rhenium in molybdenite is separated from molybdenum by distillation of rhenium heptoxide from a perchloric-sulphuric acid mixture. It is concentrated by precipitation of the sulphide and then determined by X-ray fluorescence. From 3 to 1000 ??g of rhenium can be measured with a precision generally within 2%. The procedure tolerates larger amounts of molybdenum than the usual colorimetric methods. ?? 1969.

  19. Clustering of transmutation elements tantalum, rhenium and osmium in tungsten in a fusion environment

    Science.gov (United States)

    You, Yu-Wei; Kong, Xiang-Shan; Wu, Xuebang; Liu, C. S.; Fang, Q. F.; Chen, J. L.; Luo, G.-N.

    2017-08-01

    The formation of transmutation solute-rich precipitates has been reported to seriously degrade the mechanical properties of tungsten in a fusion environment. However, the underlying mechanisms controlling the formation of the precipitates are still unknown. In this study, first-principles calculations are therefore performed to systemically determine the stable structures and binding energies of solute clusters in tungsten consisting of tantalum, rhenium and osmium atoms as well as irradiation-induced vacancies. These clusters are known to act as precursors for the formation of precipitates. We find that osmium can easily segregate to form clusters even in defect-free tungsten alloys, whereas extremely high tantalum and rhenium concentrations are required for the formation of clusters. Vacancies greatly facilitate the clustering of rhenium and osmium, while tantalum is an exception. The binding energies of vacancy-osmium clusters are found to be much higher than those of vacancy-tantalum and vacancy-rhenium clusters. Osmium is observed to strongly promote the formation of vacancy-rhenium clusters, while tantalum can suppress the formation of vacancy-rhenium and vacancy-osmium clusters. The local strain and electronic structure are analyzed to reveal the underlying mechanisms governing the cluster formation. Employing the law of mass action, we predict the evolution of the relative concentration of vacancy-rhenium clusters. This work presents a microscopic picture describing the nucleation and growth of solute clusters in tungsten alloys in a fusion reactor environment, and thereby explains recent experimental phenomena.

  20. Electrodeposition of rhenium-tin nanowires

    International Nuclear Information System (INIS)

    Naor-Pomerantz, Adi; Eliaz, Noam; Gileadi, Eliezer

    2011-01-01

    Highlights: → Rhenium-tin nanowires were formed electrochemically, without using a template. → The nanowires consisted of a crystalline-Sn-core/amorphous-Re-shell structure. → The effects of bath composition and operating conditions were investigated. → A mechanism is suggested for the formation of the core/shell structure. → The nanowires may be attractive for a variety of applications. - Abstract: Rhenium (Re) is a refractory metal which exhibits an extraordinary combination of properties. Thus, nanowires and other nanostructures of Re-alloys may possess unique properties resulting from both Re chemistry and the nanometer scale, and become attractive for a variety of applications, such as in catalysis, photovoltaic cells, and microelectronics. Rhenium-tin coatings, consisting of nanowires with a core/shell structure, were electrodeposited on copper substrates under galvanostatic or potentiostatic conditions. The effects of bath composition and operating conditions were investigated, and the chemistry and structure of the coatings were studied by a variety of analytical tools. A Re-content as high as 77 at.% or a Faradaic efficiency as high as 46% were attained. Ranges of Sn-to-Re in the plating bath, applied current density and applied potential, within which the nanowires could be formed, were determined. A mechanism was suggested, according to which Sn nanowires were first grown on top of Sn micro-particles, and then the Sn nanowires reduced the perrhenate chemically, thus forming a core made of crystalline Sn-rich phase, and a shell made of amorphous Re-rich phase. The absence of mutual solubility of Re and Sn may be the driving force for this phase separation.

  1. Neutron activation determination of rhenium in shales shales and molybdenites

    International Nuclear Information System (INIS)

    Zajtsev, E.I.; Radinovich, B.S.

    1977-01-01

    Described is the technique for neutron activation determination of rhenium in shales and molybdenites with its radiochemical extraction separation by methyl-ethyl ketone. The sensitivity of the analysis is 5x10 -7 %. Experimental checking of the developed technique in reference to the analysis of shales and molybdenites was carried out. Estimated is the possibility of application of X-ray gamma-spectrometer to instrumental determination of rhenium in molybdenites

  2. Synthesis and study of rhenium (5) complexes with benzimidazole and rubeanic acid

    Energy Technology Data Exchange (ETDEWEB)

    Basitova, S M; Yurina, R D; Kotegov, K V; Amindzhanov, A A

    1986-01-01

    Mixed rhenium (5) oxohalide complex compounds with benzimidazole and rubeanic acid are synthesized. Composition of the compounds obtained is established by IR spectroscpy thermal and chemical analyses. It is shown that rhenium (5) chloride compound stability to pyrolysis is rather lower than that of the corresponding bromide derivatives.

  3. Synthesis and study of rhenium (5) complexes with benzimidazole and rubeanic acid

    International Nuclear Information System (INIS)

    Basitova, S.M.; Yurina, R.D.; Kotegov, K.V.; Amindzhanov, A.A.

    1986-01-01

    Mixed rhenium (5) oxohalide complex compounds with benzimidazole and rubeanic acid are synthesized. Composition of the compounds obtained is established by IR spectroscpy thermal and chemical analyses. It is shown that rhenium (5) chloride compound stability to pyrolysis is rather lower than that of the corresponding bromide derivatives

  4. Rhenium Mechanical Properties and Joining Technology

    Science.gov (United States)

    Reed, Brian D.; Biaglow, James A.

    1996-01-01

    Iridium-coated rhenium (Ir/Re) provides thermal margin for high performance and long life radiation cooled rockets. Two issues that have arisen in the development of flight Ir/Re engines are the sparsity of rhenium (Re) mechanical property data (particularly at high temperatures) required for engineering design, and the inability to directly electron beam weld Re chambers to C103 nozzle skirts. To address these issues, a Re mechanical property database is being established and techniques for creating Re/C103 transition joints are being investigated. This paper discusses the tensile testing results of powder metallurgy Re samples at temperatures from 1370 to 2090 C. Also discussed is the evaluation of Re/C103 transition pieces joined by both, explosive and diffusion bonding. Finally, the evaluation of full size Re transition pieces, joined by inertia welding, as well as explosive and diffusion bonding, is detailed.

  5. Mechanistic Study of Oxygen Atom Transfer Catalyzed by Rhenium Compounds

    Energy Technology Data Exchange (ETDEWEB)

    Shan, Xiaopeng [Iowa State Univ., Ames, IA (United States)

    2003-01-01

    Two ionic and one neutral methyl(oxo)rhenium(V) compounds were synthesized and structurally characterized. They were compared in reactivity towards the ligands triphenylphosphane, pyridines, pyridine N-oxides. Assistance from Broensted bases was found on ligand displacement of ionic rhenium compounds as well as nucleophile assistance on oxidation of all compounds. From the kinetic data, crystal structures, and an analysis of the intermediates, a structural formula of PicH+3- and mechanisms of ligand displacement and oxidation were proposed.

  6. Development of a new surface ion-source and ion guide in the ALTO project

    International Nuclear Information System (INIS)

    Cuong, P.V.

    2009-12-01

    The present work is dedicated to the ALTO project which is the production of neutron-rich gallium isotopes by the ISOL thick-target technique using photo-fission and a surface ion source. We aim at the study of the structure of 82 Ge, 83 Ge, 84 Ge via the β decay of 82 Ga, 83 Ga, and 84 Ga. We focus on the development of a new surface ion source made from materials with a high work function φ which can give high ionisation efficiencies for elements with low ionisation potentials, like alkaline as well as gallium and indium. Tungsten, rhenium and iridium are considered as good candidates for a surface ionizer because the Saha-Langmuir equation indicates high surface ionisation efficiencies for these materials. This has motivated us to equip the surface ion source at ALTO with rhenium and iridium-coated rhenium ionizer tubes of the same dimensions as the surface ion source at ISOLDE. We performed a test experiment to measure the ionisation efficiency for gallium. We also built a simulation code for the ionisation efficiency of the different surface ionisation sources (different materials and dimensions). On the other hand, for future nuclear structure studies of refractory elements such as cobalt or nickel, the ISOL technique with a thick target is no longer suitable. Indeed, the high melting point of these elements makes it difficult to volatilize and release them from a thick target. For such a situation, a technique based on thin targets is needed and the laser ion guide based on a gas cell to slow down, neutralize and stop the recoiling nuclear reaction products combined with a laser beam to re-ionize them selectively, seems a good choice. A code based on the Geant-4 tool-kit has been built to simulate the ionisation of the buffer gas. In this work, we also briefly show the results of the photo-fission yield measurements at ALTO. The fission fragments were ionized in a hot plasma ion source, mass separated and detected by germanium and scintillator detectors

  7. Lymph node scintigraphy with sup(99m)Tc-rhenium colloid

    International Nuclear Information System (INIS)

    Mitsuhata, Naoki; Suyama, Bunzo; Matsumura, Yosuke; Ohmori, Hiroyuki

    1981-01-01

    Lymph node scintigraphy with sup(99m)Tc-rhenium colloid in evaluation of nodal involvement by urological malignancy were performed on twelve cases (4 bladder cancer, 3 prostatic cancer, 2 penile cancer and 3 testicular tumor). These cases had been examined the extent of disease on the basis of findings at pedal lymphangiography, urography, computed tomography or laparotomy. sup(99m)Tc-rhenium colloid in a volume of 0.2 ml (2 mCi) was injected into the first interdigital webs of each foot without local anesthesia. In one case of penile cancer radioactive colloid was directly injected into the glans penis and prepuce including tumor area. Our clinical experience reported here reveals that lymph node scintigraphy with sup(99m)Tc-rhenium colloid can provide a useful method of investigating the lymphatic system. This technique is reproducible and can be performed in poor risk patients or pediatric patients readily and safely. (author)

  8. Study of the electrodeposition of rhenium thin films by electrochemical quartz microbalance and X-ray photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Schrebler, R.; Cury, P.; Suarez, C.; Munoz, E.; Vera, F.; Cordova, R.; Gomez, H.; Ramos-Barrado, J.R.; Leinen, D.; Dalchiele, E.A.

    2005-01-01

    Rhenium thin films were prepared by electrodeposition from an aqueous solution containing 0.1 M Na 2 SO 4 +H 2 SO 4 , pH 2 in presence of y mM HReO 4 . As substrates polycrystalline gold (y=0.75 mM HReO 4 ) and monocrystalline n-Si(100) (y=40 mM HReO 4 ) were used. The electrochemical growth of rhenium was studied by cyclic voltammetry and electrochemical quartz microbalance on gold electrodes. The results found in the potential region before the hydrogen evolution reaction (her) showed that ReO 3 , ReO 2 and Re 2 O 3 with different hydration grades can be formed. In the potential region where the her is occurring, either on gold or n-Si(100) the electrodeposition of metallic rhenium takes place. On both substrates, rhenium films were formed by electrolysis at constant potential and X-ray photoelectron spectroscopy technique was used to characterise these deposits. It was concluded that the electrodeposited films were of metallic rhenium and only the uppermost atomic layer contained rhenium oxide species

  9. High-temperature extraction of rhenium from sulfuric acid solutions with trialkylamines

    International Nuclear Information System (INIS)

    Gladyhev, V.P.; Andreeva, N.N.; Kim, E.M.; Kovaleva, S.V.

    1985-01-01

    This paper attempts to determine the possibility of conducting high-temperature extraction of rhenium from sulfuric acid solutions with trialkylamines (TAA) using higher hydrocarbon-paraffin mixtures as the diluent of the extraction system. Substitution of kerosene by paraffin in the extraction system would permit decreasing the danger of fire and explosions during he extraction process. In extracting rhenium from industrial solutions with a melt of higher paraffins containing TAA and alcohols, the extraction system can be continously heated in heat exchangers through which washing sulfuric acid passes and then goes to the extractor. This permits utilizing the heat and decreases the temperature of the solutions for extraction to the optimum temperatures. Extraction of rhenium with a melt of trioctylamine in paraffin obeys the same mechanisms as high-temperature extraction of ruthenium (IV) by amines in kerosene and aromatic hydrocarbons

  10. Influence of nano-cluster compounds of rhenium drugs on the activity of liver enzymes in a tumor model

    Directory of Open Access Journals (Sweden)

    J. V. Suponko

    2010-06-01

    Full Text Available Enzymes’ level in rat’s hepatocytes under Guerin's carcinoma T8 development as well as after injection of rhenium compounds and cis-platin has been studied. It has been determined that the decrease of enzymatic activity to the level of the animals of control group was observed at the simultaneous injection of cis-platin and cluster rhenium compounds in nanoliposomal and water-soluble forms. That confirms possible hepatoprotective properties of the rhenium compounds. It has been shown that hepatoprotective properties of rhenium cluster compounds mostly don’t depend on the form of their injection and are detected regardless of anticancer properties. Rhenium-platinum system with β-alanine ligand in aqueous solution, has been found. Its injection is accompanied by the hepatoprotective effect.

  11. Reductive coupling of carbon monoxide in a rhenium carbonyl complex with pendant Lewis acids.

    Science.gov (United States)

    Miller, Alexander J M; Labinger, Jay A; Bercaw, John E

    2008-09-10

    Phosphinoborane ligands impart unique reactivity to a rhenium carbonyl cation relative to simple phosphine complexes. Addition of either triethylborohydride or a platinum hydride (that can be formed from H2) forms a rhenium boroxycarbene. This carbene, which crystallizes as a dimer, disproportionates over a period of days to afford the starting cation and a structurally unprecedented boroxy(boroxymethyl)carbene, in which a new C-C bond has been formed between two reduced CO ligands. This product of C-C bond formation can be independently synthesized by addition of 2 equiv of hydride to the rhenium carbonyl cation.

  12. Use of cluster rhenium substances with alkyl ligands for inhibition of the Guerin carcinoma Growth

    Directory of Open Access Journals (Sweden)

    O. S. Voronkova

    2007-04-01

    Full Text Available Quantity and quality of erythrocytes, blood haemoglobin concentration, glucose levels in the erythrocytes and plasma, content of TBA-active products in blood plasma of rats were studied during development of the Guerin carcinoma, introduction of cis-platinum and cluster rhenium substances with organic ligands. It was shown that rhenium substances had essential antioxidant effects and changed the dynamic of tumour growth. The conclusion on perspectiveness of further investigations of rhenium substances with cluster fragment and organic ligands in experiments in vivo with changed redox-status of an organism was drawn.

  13. A study of scandia and rhenium doped tungsten matrix dispenser cathode

    Science.gov (United States)

    Wang, Jinshu; Li, Lili; Liu, Wei; Wang, Yanchun; Zhao, Lei; Zhou, Meiling

    2007-10-01

    Scandia and rhenium doped tungsten powders were prepared by solid-liquid doping combined with two-step reduction method. The experimental results show that scandia was distributed evenly on the surface of tungsten particles. The addition of scandia and rhenium could decrease the particle size of doped tungsten, for example, the tungsten powders doped with Sc 2O 3 and Re had the average size of about 50 nm in diameter. By using this kind of powder, scandia and rhenium doped tungsten matrix with the sub-micrometer sized tungsten grains was obtained. This kind of matrix exhibited good anti-bombardment insensitivity at high temperature. The emission property result showed that high space charge limited current densities of more than 60 A/cm 2 at 900 °C could be obtained for this cathode. A Ba-Sc-O multilayer about 100 nm in thickness formed at the surface of cathode after activation led to the high emission property.

  14. Characterization of rhenium compounds obtained by electrochemical synthesis after aging process

    Energy Technology Data Exchange (ETDEWEB)

    Vargas-Uscategui, Alejandro, E-mail: avargasuscat@ing.uchile.cl [Departamento de Ingeniería de Minas, Facultad de Ciencias Físicas y Matemáticas, Universidad de Chile, Tupper Av. 2069, Santiago (Chile); Mosquera, Edgar [Laboratorio de Materiales a Nanoescala, Departamento de Ciencia de los Materiales, Facultad de Ciencias Físicas y Matemáticas, Universidad de Chile, Tupper Av. 2069, Santiago (Chile); López-Encarnación, Juan M. [Department of Mathematics-Physics and Department of Chemistry, University of Puerto Rico at Cayey, 205 Ave. Antonio R. Barceló, Cayey, PR 00736, USA. (Puerto Rico); Chornik, Boris [Departamento de Física, Facultad de Ciencias Físicas y Matemáticas, Universidad de Chile, Blanco Encalada Av. 2008, Santiago (Chile); Katiyar, Ram S. [Department of Physics and Institute for Functional Nanomaterials, University of Puerto Rico San Juan, San Juan, PR 00931-3343 (United States); Cifuentes, Luis [Departamento de Ingeniería de Minas, Facultad de Ciencias Físicas y Matemáticas, Universidad de Chile, Tupper Av. 2069, Santiago (Chile)

    2014-12-15

    The proper identification of the molecular nature of the aged rhenium compound obtained by means of electrodeposition from an alkaline aqueous electrolyte was determined. Chemical, structural and vibrational experimental characterization of the aged Re compound showed agreement with quantum-computations, thereby allowing the unambiguous identification of the Re compound as H(ReO{sub 4})H{sub 2}O. - Graphical abstract: Rhenium oxides were electrodeposited on a copper surface and after environmental aging was formed the H(ReO{sub 4})H{sub 2}O compound. The characterization of the synthesized material was made through the comparison of experimental evidence with quantum mechanical computations carried out by means of density functional theory (DFT). - Highlights: • Aged rhenium compound obtained by means of electrodeposition was studied. • The study was made by combining experimental and DFT-computational information. • The aged electrodeposited material is consistent with the H(ReO{sub 4})H{sub 2}O compound.

  15. Evaluation of oxide dispersion strengthened (ODS) molybdenum and molybdenum-rhenium alloys

    International Nuclear Information System (INIS)

    Mueller, A.J.; Bianco, R.; Buckman, R.W. Jr.

    1999-01-01

    Oxide dispersion strengthened (ODS) molybdenum alloys being developed for high temperature applications possess excellent high temperature strength and creep resistance. In addition they exhibit a ductile-to-brittle transition temperature (DBIT) in the worked and stress-relieved condition under longitudinal tensile load well below room temperature. However, in the recrystallized condition, the DBTT maybe near or above room temperature, depending on the volume fraction of oxide dispersion and the amount of prior work. Dilute rhenium additions (7 and 14 wt.%) to ODS molybdenum were evaluated to determine their effect on low temperature ductility. The addition of 7 wt.% rhenium to the ODS molybdenum did not significantly enhance the mechanical properties. However, the addition of 14 wt.% rhenium to the ODS molybdenum resulted in a DBTT well below room temperature in both the stress-relieved and recrystallized condition. Additionally, the tensile strength of ODS Mo-14Re is greater than the base ODS molybdenum at 1,000 to 1,250 C

  16. Influence of cold rolling and strain rate on plastic response of powder metallurgy and chemical vapor deposition rhenium

    International Nuclear Information System (INIS)

    Koeppel, B.J.; Subhash, G.

    1999-01-01

    The plastic response of two kinds of rhenium processed via powder metallurgy (PM) and chemical vapor deposition (CVD) were investigated under uniaxial compression over a range of strain rates. The PM rhenium, further cold rolled to 50 and 80 pct of the original thickness, was also investigated to assess the influence of cold work on the plastic behavior. A strong basal texture was detected in all the preceding materials as a result of processing and cold work. Both CVD and PM rhenium exhibited an increase in yield strength and flow stress with increasing strain rate. In PM rhenium, cold work resulted in an increase in hardness and yield strength and a decrease in the work hardening rate. The deformed microstructures revealed extensive twinning in CVD rhenium. At large strains, inhomogeneous deformation mode in the form of classical cup and cone fracture was noticed

  17. Nanograined Net-Shaped Fabrication of Rhenium Components by EB-PVD

    International Nuclear Information System (INIS)

    Singh, Jogender; Wolfe, Douglas E.

    2004-01-01

    Cost-effective net-shaped forming components have brought considerable interest into DoD, NASA and DoE. Electron beam physical vapor deposition (EB-PVD) offers flexibility in forming net-shaped components with tailored microstructure and chemistry. High purity rhenium (Re) components including rhenium-coated graphite balls, Re- plates and tubes have been successfully manufactured by EB-PVD. EB-PVD Re components exhibited sub-micron and nano-sized grains with high hardness and strength as compared to CVD. It is estimated that the cost of Re components manufactured by EB-PVD would be less than the current CVD and powder-HIP Technologies

  18. Effect of octanols structure on their extraction ability as regards to rhenium(VII) in sulfuric acid solutions

    International Nuclear Information System (INIS)

    Kasikov, A.G.; Petrova, A.M.

    2007-01-01

    It is established that extraction ability of octanols as regards to rhenium(VII) and sulfuric acid depends on the structure of alcohol, but if in passage from octanol-1 to octanol-3 as regard to rhenium(VII) it rises, then for H 2 SO 4 it falls. Dependence of the distribution function of rhenium from the concentration of the acid has maximums at 4-7 mol l 1- that the most distinctly it becomes apparent for secondary alcohols. Decreasing the extraction ability of octyl alcohols with the growth of H 2 SO 4 concentration more than 7 mol l 1- is connected with the change of extractant composition and forms of rhenium(VII) being in the solution [ru

  19. Treatment of liver cancer with Rhenium-188 Lipiodol: Colombian experience

    International Nuclear Information System (INIS)

    Bernal, P.; Osorio, M.; Mendoza, M.; Esguerra, R.; Ucros, G.; Gutierrez, C.; Velez, O.; Cerquera, A.M.; Padhy, A.K.

    2002-01-01

    Aim:Trans-arterial Radio-conjugate therapy plays an important role in the palliative treatment of inoperable liver cancer. It also helps in reduction of the tumor to an operable state from an inoperable one. As a part of an IAEA sponsored coordinated research project, a new radiopharmaceutical, Rhenium-188 Lipiodol has been developed. The aim of this study was to establish the safety of the radiopharmaceutical and to find out the efficacy of treatment. Materials and Methods: Eight patients suffering from various forms of liver cancer (Hepatocellular carcinoma-4, Metastases from carcinoma of colon-3 and Carcinoid- 1) were treated with Rhenium -188 Lipiodol. Seven out of the eight patients were classified as ECOG- 1 and one as ECOG- 3. Labelling of Rhenium-188 with Lipiodol was carried out according to a protocol developed under the CRP and standardized in our service. Rhenium-188 Lipiodol was administered through the trans-arterial route by either selective (75%) or ultra selective (25%) hepatic arteriography. Administered therapeutic doses ranged between 170 MBq and 4181 MBq. Dosimetric evaluations were made using the IAEA developed dosimetry spreadsheet. All patients were followed up (1-5 months, average = 2 months) after treatment by clinical examination, liver function tests, haematological examinations and CT scans of liver to determine the size of hepatic tumor. Results: Rhenium-188 Lipiodol treatment was well tolerated by all patients. No immediate systemic complications were noted in any of the patients within 72 hrs. following therapy. Only two patients had mild rise in temperature in the immediate post-therapy period, which subsided subsequently. One patient who was classified as Child B and ECOG 3, developed encephalopathy on the seventh day after treatment. He died of hepatic failure. Another one present depressive syndrome, didn't accept food and died Follow-up CT scans in all the surviving (6/8) patients revealed significant reduction of the tumours

  20. THE SYNTHESIS OF BIOCONJUGATE BASED ON RHENIUM(I CARBONYL COMPLEX FOR VISUALIZATION OF PATHOLOGICAL PROCESS

    Directory of Open Access Journals (Sweden)

    K. O. Piletska

    2017-03-01

    Full Text Available Tricarbonyl rhenium(I complexes have a great potential like biomarkers. It is caused their biological stability, low toxicity, large Stokes shifts, and long luminescence lifetimes. Rhenium tricarbonyl complexes fac-[Re(CO3(N^N], where N^N is a ligand with low π* orbitals are excellent candidates as imaging dyes. The method of obtaining potential biomarkers based on tricarbonyl rhenium(I complex with a 4-methyl-2,2’-bipyridine-4’-carboxylate by the addition of biomolecules by peptide synthesis was developed. The new complex [Re(CO3MebpyCOOHBr] was synthesized, composition and structure of which were established by mass spectrometry, IR and NMR spectroscopy. A selective attachment of receptor peptide enkephalin to complex [Re(CO3(MebpyCOOHBr] was performed. The formation of a new compound and its structure has been confirmed by HPLC and mass spectral analysis. The method which has been developed allows to connect various peptides to rhenium(I complex in the solution.

  1. Structure and x-ray density of electrochemically deposited rhenium films

    International Nuclear Information System (INIS)

    Petrovich, V.A.; Fedenkov, A.L.; Shepurev, S.Yu.

    1988-01-01

    The electrodeposition of rhenium was carried out at a constant cathode-current density and room temperature. The backing was grade KEF-0.02 single-crystal silicon. The absorption coefficient μ of the film was determined for the K α radiation of the copper line. The investigation enabled us to conclude that electrochemically deposited rhenium films can be used as a material for the masking coatings of x-ray patterns, since the absorption coefficients of the x-ray radiation of the resultant films are superior to the similar parameters of traditionally employed materials, and surpass these materials in terms of corrosion resistance and simplicity of production

  2. Determination coefficient distribution rhenium and tungsten using method extraction with solvent methyl ethyl ketone

    International Nuclear Information System (INIS)

    Riftanio Natapratama Hidayat; Maria Christina Prihatiningsih; Duyeh Setiawan

    2015-01-01

    Determination of the distribution coefficient (K d ) of the rhenium and tungsten conducted for the purpose of knowing the value of K d of the two elements. K d value determination is applied to the process of separation rhenium-188 from target of tungsten-188 for the purposes purification of radioisotopes that are made to meet the radionuclide and radiochemical purity. The K d value determination using solvent extraction with methyl ethyl ketone (MEK). Prior to the determination of K d values, determined beforehand the optimum conditions of extraction process based on the effect of agitation time, the volume of MEK, and the pH of the solution. Confirmation the results of the extraction was conducted using UV-Vis spectrophotometer with a complexing KSCN under acidic conditions and reductant SnCl 2 . The results showed that the optimum condition extraction process to feed each of 10 ppm is when the agitation for 10 minutes, the volume of MEK in 20 ml, and the pH below 5. Obtained the maximum recovery of rhenium are drawn to the organic phase as much as 9.545 ppm. However, the condition of the extraction process does not affect the migration of tungsten to the organic phase. Then the maximum K d values obtained at 2.7566 rhenium and tungsten maximum K d is 0.0873. Optimum conditions of extraction process can be further tested on radioactive rhenium and tungsten as an alternative to the separation of radioisotopes. (author)

  3. Synthesis, reactivity, and properties of N-fused porphyrin rhenium(I) tricarbonyl complexes.

    Science.gov (United States)

    Toganoh, Motoki; Ikeda, Shinya; Furuta, Hiroyuki

    2007-11-12

    The thermal reactions of N-fused tetraarylporphyrins or N-confused tetraarylporphyrins with Re2(CO)10 gave the rhenium(I) tricarbonyl complexes bearing N-fused porphyrinato ligands (4) in moderate to good yields. The rhenium complexes 4 are characterized by mass, IR, 1H, and 13C NMR spectroscopy, and the structures of tetraphenylporphynato complex 4a and its nitro derivative 15 are determined by X-ray single crystal analysis. The rhenium complexes 4 show excellent stability against heat, light, acids, bases, and oxidants. The aromatic substitution reactions of 4 proceed without a loss of the center metal to give the nitro (15), formyl (16), benzoyl (17), and cyano derivatives (19), regioselectively. In the electrochemical measurements for 4, one reversible oxidation wave and two reversible reduction waves are observed. Their redox potentials imply narrow HOMO-LUMO band gaps of 4 and are consistent with their electronic absorption spectra, in which the absorption edges exceed 1000 nm. Theoretical study reveals that the HOMO and LUMO of the rhenium complexes are exclusively composed of the N-fused porphyrin skeleton. Protonation of 4 takes place at the 21-position regioselectively, reflecting the high coefficient of the C21 atom in the HOMO orbital. The skeletal rearrangement reaction from N-confused porphyrin Re(I) complex (8) to N-fused porphyrin Re(I) complex (4) is suggested from the mechanistic study as well as DFT calculations.

  4. Extraction of rhenium(VII) by phosphorylated podands

    International Nuclear Information System (INIS)

    Turanov, A.N.; Karandashev, V.K.; Baulin, V.E.

    2006-01-01

    Interphase distribution of ReO 4 - between aqueous solutions of H 2 SO 4 and solutions of phosphoryl-containing podands in organic solvents is studied. Stoichiometry of the complexes extracted is determined. Effect of extractant structure and nature of organic solvent on efficiency of rhenium extraction into organic phase is determined [ru

  5. Chromatographic separation of rhenium in alumina-methanol/sulfuric acid system

    International Nuclear Information System (INIS)

    Oguma, Koichi

    1983-01-01

    The adsorption behavior of a number of metals on alumina was surveyed in a methanol-(0.005 -- 0.5) M H 2 SO 4 (3 : 1 v/v) developing solvent by thin-layer chromatography. Over the acid concentration range tested, Re(VII) does not favor the alumina phase to any great extent while the most other metals are strongly adsorbed on alumina. These findings allowed to establish a column chromatographic technique for selective separation of rhenium in a methanol-0.05 M H 2 SO 4 (3 : 1 v/v) eluent. The separation technique thus established was applied to molybdenite analysis for rhenium. About 100-mg powdered sample containing ca. 100 ppm rhenium was decomposed with HNO 3 and then evaporated nearly to dryness. The residue was dissolved in NH 4 OH and the excess NH 4 OH was expelled by evaporation to dryness. The residue was dissolved in 2.5-ml 0.5 M H 2 SO 4 and 10-ml water, the insoluble materials filtered off, and the filtrate diluted to exactly 25 ml with water. A 10-ml aliquot of this solution was mixed with 30-ml methanol and the mixture was passed through a column (diameter 15 mm, bed height 30 mm) containing 5 g of alumina. The column was then washed with 20 ml of a methanol-0.05 M H 2 SO 4 (3 : 1 v/v) mixture. Rhenium was recovered from the loaded solution and the subsequent washings, and was determined spectrophotometrically with Methylene Blue as a chromogenic reagent. The values obtained from four samples of molybdenite are in good agreement with those obtained by neutron activation analysis. The relative standard deviation (n = 4; calculated from the range) was between 2.0 and 5.2 %. (author)

  6. Development of unified X-ray fluorescent analysis to determine rhenium content in multicomponent oxide compositions

    International Nuclear Information System (INIS)

    Drobot, D.V.; Belyaev, A.V.; Kutvitskij, V.A.; Rysev, A.P.

    1999-01-01

    A procedure to prepare rhenium-containing glass-like specimens on the basis of bismuth and boron oxides is proposed. The glasses produced are studied by X-ray fluorescent analysis and routine spectrometric thiocyanate analysis. The results make it possible to determine rhenium in oxide mixtures in the range of its content 0.01 - 10% with S r = 0.03 [ru

  7. A Study on the Trapping Characteristics of Rhenium Oxide Using Ca(OH)_2

    International Nuclear Information System (INIS)

    Lee, Tae-Kyo; Eun, Hee-Chul; Choi, Jung-Hoon; Lee, Ki-Rak; Han, Seung-Youb; Park, Hwan-Seo

    2017-01-01

    The objective of this study was to obtain basic data for trapping gaseous technetium (Tc) oxide generated from the voloxidation process in spent nuclear fuel pyroprocessing. Rhenium (Re) and Ca(OH)_2 were used as surrogates for the technetium and a trapping material, respectively. The trapping characteristics of rhenium oxide were investigated with changing temperatures and molar ratios of calcium (Ca) over rhenium, and the thermal behaviors of the trapping products were observed. The products following after the trapping test were identified as Ca(ReO_4)_2 and Ca_5Re_2O_1_2. The conversion to Ca_5Re_2O_1_2 was preferred with increasing temperatures, and the trapping products were completely converted into Ca5Re2O12 under conditions exceeding 800 ℃, or when maintained at 750 ℃ for 4 hr. The trapping efficiency at a molar ratio of 2.5 (Ca:Re=5:2) was significantly superior to that at the molar ratio of 2.

  8. Tungsten-rhenium composite tube fabricated by CVD for application in 18000C high thermal efficiency fuel processing furnace

    International Nuclear Information System (INIS)

    Svedberg, R.C.; Bowen, W.W.; Buckman, R.W. Jr.

    1980-04-01

    Chemical Vapor Deposit (CVD) rhenium was selected as the muffle material for an 1800 0 C high thermal efficiency fuel processing furnace. The muffle is exposed to high vacuum on the heater/insulation/instrumentation side and to a flowing argon-8 V/0 hydrogen gas mixture at one atmosphere pressure on the load volume side. During operation, the muffle cycles from room temperature to 1800 0 C and back to room temperature once every 24 hours. Operational life is dependent on resistance to thermal fatigue during the high temperature exposure. For a prototypical furnace, the muffle is approximately 13 cm I.D. and 40 cm in length. A small (about one-half size) rhenium closed end tube overcoated with tungsten was used to evaluate the concept. The fabrication and testing of the composite tungsten-rhenium tube and prototypic rhenium muffle is described

  9. Influence of ligand structure on anticancer and antioxidant properties of rhenium cluster compounds

    Directory of Open Access Journals (Sweden)

    I. V. Leus

    2009-11-01

    Full Text Available Under the model growth of T8 Guerin’s carcinoma in rats we studied the anticancer activity of the system rhenium-platinum, which includes cis-dicarboxylates of rhenium (III with different alkyl ligands, erythrocytes number and its morphological structure, erythrocytic stability, blood haemoglobin concentration, catalase activity and concentration of TBA-active products in the rats blood plasma. The renium-platinum system had considerable antioxidat effect and prevented the growth of tumour, that was maximal for a compound with the pivalate ligand.

  10. Determination of rhenium (7) trace amounts by spectrophotometric titration in medium of mixed solvents

    International Nuclear Information System (INIS)

    Kuznetsov, V.V.; Samorukova, O.L.

    1978-01-01

    The method has been proposed of determining rhenium (7) microamounts by spectrophotometric titration in the medium water-dimethyl-sulphoxide with the reagent nitrochromazo. The method is based on the formation of ionic pairs K + ReO 4 - in water-organic solvents. The results of rhenium determination are satisfactory in a wide concentration range up to 0.3 mkg in 15 ml which makes the method proposed close in sensitivity to photometric methods and much better in reproducibility

  11. Reductive Coupling of Carbon Monoxide in a Rhenium Carbonyl Complex with Pendant Lewis Acids

    OpenAIRE

    Miller, Alexander J. M.; Labinger, Jay A.; Bercaw, John E.

    2008-01-01

    Phosphinoborane ligands impart unique reactivity to a rhenium carbonyl cation relative to simple phosphine complexes. Addition of either triethylborohydride or a platinum hydride (that can be formed from H2) forms a rhenium boroxycarbene. This carbene, which crystallizes as a dimer, disproportionates over a period of days to afford the starting cation and a structurally unprecedented boroxy(boroxymethyl)carbene, in which a new C−C bond has been formed between two reduced CO ligands. This prod...

  12. Tungsten - rhenium alloys wire: overview of thermomechanical processing and properties data

    International Nuclear Information System (INIS)

    Bryskin, B.

    2001-01-01

    The scope of this study encompasses the compositional modifications of the tungsten-rhenium dual system (W-3/5 Re up to W-27 Re) as well as some of the tungsten-molybdenum-rhenium ternary system. The alloys of interest are considered with a specific representation of powder metallurgy route based on doped or undoped tungsten vs. vacuum melted materials. This paper constitutes an in-depth review of structural and mechanical properties and systematic compilation of challenges necessary to provide the quality consistency of severely drawn filaments. The issue of thermomechanical processing trends is addressed as an important part of W-Re fabrication technology to achieve further improvement in design properties of rod and wire. (author)

  13. Noncontact surface tension and viscosity measurements of rhenium in the liquid and undercooled states

    International Nuclear Information System (INIS)

    Ishikawa, Takehiko; Paradis, Paul-Francois; Yoda, Shinichi

    2004-01-01

    Surface tension and viscosity of liquid rhenium, which have hardly been measured due to the extremely high melting temperature of rhenium, were measured using an electrostatic levitation method combined with the oscillation drop technique. Sample position instability problems caused by the photon pressure of the heating lasers and by sample evaporation were solved by modifying the electrodes design. Good sample stability allowed the measurements of the surface tension and the viscosity over wide temperature ranges including the undercooled states. Over the 2800-3600 K interval, the surface tension of rhenium was measured as σ(T)=2.71x10 3 -0.23(T-T m ), where T m is the melting temperature, 3453 K. At T m , the datum agrees well with the literature values. Similarly, on the same temperature range, the viscosity was determined as η(T)=0.08 exp[1.33x10 5 /(RT)] (mPa s)

  14. Thermal decomposition of rhenium (5) complexes with 1,2,4-triazole. Termicheskoe razlozhenie kompleksov reniya (5) s 1,2,4-triazolom

    Energy Technology Data Exchange (ETDEWEB)

    Amindzhanov, A A; Gagieva, S Ch; Kotegov, K V [Tadzhikskij Gosudarstvennyj Univ., Dushanbe (Tajikistan)

    1991-01-01

    Processes of thermal decomposition of rhenium (5) complexes with 1,2,4-triazole were studied. Thermolysis products were identified on the basis of data of the element analysis, IR spectra, conductometry and other methods. It is ascertained that at the first stage of thermolysis of hydroxyl-containing monomer complexes removal of water molecules occurs, and at the second one - dimerization process with formation of Re-O-Re group. It is shown that the nature of halide ion practically does not affect the temperature of the start of intensive thermal decomposition of the complexes.

  15. Monte Carlo criticality analysis of simple geometries containing tungsten-rhenium alloys engrained with uranium dioxide and uranium mononitride

    International Nuclear Information System (INIS)

    Webb, Jonathan A.; Charit, Indrajit

    2011-01-01

    Highlights: → The addition of rhenium to the tungsten matrix within W-UO 2 and W-UN CERMET materials can help reduce the risk of submersion criticality accidents while increasing the strength and ductility of tungsten based nuclear fuel elements. → The addition of rhenium up to 30 at.% to simple geometries containing W-UO 2 mixtures can increase the critical mass by 65 kg. → The addition of rhenium up to 30 at.% to simple geometries containing W-UN mixtures can increase the critical mass by 22 kg. → The addition of rhenium by up to 30 at.% to simple geometries containing W-UO 2 mixtures can reduce the change in reactivity change due to water submersion by $5.07. → The addition of rhenium by up to 30 at.% to simple geometries containing W-UN mixtures can reduce the change in reactivity due to water submersion by $3.24. - Abstract: The critical mass and dimensions of simple geometries containing highly enriched uranium dioxide (UO 2 ) and uranium mononitride (UN) encapsulated in tungsten-rhenium alloys are determined using MCNP5 criticality calculations. Spheres as well as cylinders with length to radius ratios of 1.82 are computationally built to consist of 60 vol.% fuel and 40 vol.% metal matrix. Within the geometries, the uranium is enriched to 93 wt.% uranium-235 and the rhenium content within the metal alloy was modeled over the range of 0-30 at.%. The spheres containing UO 2 were determined to have a critical radius of 18.29-19.11 cm and a critical mass ranging from 366 kg to 424 kg. The cylinders containing UO 2 were found to have a critical radius ranging from 17.07 cm to 17.84 cm with a corresponding critical mass of 406-471 kg. Spheres engrained with UN were determined to have a critical radius ranging from 14.82 cm to 15.19 cm and a critical mass between 222 kg and 242 kg. Cylinders which were engrained with UN were determined to have a critical radius ranging from 13.81 cm to 14.15 cm and a corresponding critical mass of 245-267 kg. The critical

  16. Rhenium solubility in borosilicate nuclear waste glass: implications for the processing and immobilization of technetium-99.

    Science.gov (United States)

    McCloy, John S; Riley, Brian J; Goel, Ashutosh; Liezers, Martin; Schweiger, Michael J; Rodriguez, Carmen P; Hrma, Pavel; Kim, Dong-Sang; Lukens, Wayne W; Kruger, Albert A

    2012-11-20

    The immobilization of technetium-99 ((99)Tc) in a suitable host matrix has proven to be a challenging task for researchers in the nuclear waste community around the world. In this context, the present work reports on the solubility and retention of rhenium, a nonradioactive surrogate for (99)Tc, in a sodium borosilicate glass. Glasses containing target Re concentrations from 0 to 10,000 ppm [by mass, added as KReO(4) (Re(7+))] were synthesized in vacuum-sealed quartz ampules to minimize the loss of Re from volatilization during melting at 1000 °C. The rhenium was found as Re(7+) in all of the glasses as observed by X-ray absorption near-edge structure. The solubility of Re in borosilicate glasses was determined to be ~3000 ppm (by mass) using inductively coupled plasma optical emission spectroscopy. At higher rhenium concentrations, additional rhenium was retained in the glasses as crystalline inclusions of alkali perrhenates detected with X-ray diffraction. Since (99)Tc concentrations in a glass waste form are predicted to be wastes, assuming Tc as Tc(7+) and similarities between Re(7+) and Tc(7+) behavior in this glass system.

  17. Submersion criticality safety of tungsten-rhenium urania cermet fuel for space propulsion and power applications

    Energy Technology Data Exchange (ETDEWEB)

    Craft, A.E., E-mail: aaron.craft@inl.gov [Center for Space Nuclear Research (CSNR), INL, Idaho Falls, ID (United States); O’Brien, R.C., E-mail: Robert.OBrien@inl.gov [Center for Space Nuclear Research (CSNR), INL, Idaho Falls, ID (United States); Howe, S.D., E-mail: Steven.Howe@inl.gov [Center for Space Nuclear Research (CSNR), INL, Idaho Falls, ID (United States); King, J.C., E-mail: kingjc@mines.edu [Nuclear Science and Engineering Program, Metallurgical and Materials Engineering Department, Colorado School of Mines, Golden, CO 80401 (United States)

    2014-07-01

    Highlights: • Criticality safety studies consider a generic space nuclear reactor in reentry scenarios. • Describes the submersion criticality behavior for a reactor fueled with a tungsten cermet fuel. • Study considers effects of varying fuel content, geometry, and other conditions. - Abstract: Nuclear thermal rockets are the preferred propulsion technology for a manned mission to Mars, and tungsten–uranium oxide cermet fuels could provide significant performance and cost advantages for nuclear thermal rockets. A nuclear reactor intended for use in space must remain subcritical before and during launch, and must remain subcritical in launch abort scenarios where the reactor falls back to Earth and becomes submerged in terrestrial materials (including seawater, wet sand, or dry sand). Submersion increases reflection of neutrons and also thermalizes the neutron spectrum, which typically increases the reactivity of the core. This effect is typically very significant for compact, fast-spectrum reactors. This paper provides a submersion criticality safety analysis for a representative tungsten/uranium oxide fueled reactor with a range of fuel compositions. Each submersion case considers both the rhenium content in the matrix alloy and the uranium oxide volume fraction in the cermet. The inclusion of rhenium significantly improves the submersion criticality safety of the reactor. While increased uranium oxide content increases the reactivity of the core, it does not significantly affect the submersion behavior of the reactor. There is no significant difference in submersion behavior between reactors with rhenium distributed within the cermet matrix and reactors with a rhenium clad in the coolant channels. The combination of the flooding of the coolant channels in submersion scenarios and the presence of a significant amount of spectral shift absorbers (i.e. high rhenium concentration) further decreases reactivity for short reactor cores compared to longer cores.

  18. Separation of tungsten and rhenium on alumina

    Directory of Open Access Journals (Sweden)

    MILOVAN SM. STOILJKOVIC

    2004-09-01

    Full Text Available The conditions for the efficient separation of tungsten(VI and rhenium (VII on alumina were established. The distribution coefficients Kd for tungstate and perrhenate anions, as well as the separation factors a (a = KdWO42-/Kd ReO4- were determined using hydrochloric or nitric acid as the aqueous media. A solution of sodium chloride in the pH range 2–6 was also examined. Under all the tested experimental conditions, alumina is a much better adsorbent for tungsten than for rhenium. The obtained results indicated that the best separation of these two elements is achieved when 0.01– 0.1 mol dm-3 HCl or 1.0 mol dm-3 HNO3 are used as the aqueous media. If NaCl is used as the aqueous phase, the best separation is achieved with 0.20 mol dm-3 NaCl, pH 4–6. Under these experimental conditions, the breakthrough and saturation capacities of alumina for tungsten at pH 4 are 17 and 26 mg W/g Al2O3, respectively. With increasing pH, these values decrease. Thus, at pH 6 they are only 4 and 13 mg W/g Al2O3, respectively.

  19. Separation of Rhenium from Lead-Rich Molybdenite Concentrate via Hydrochloric Acid Leaching Followed by Oxidative Roasting

    Directory of Open Access Journals (Sweden)

    Guanghui Li

    2016-11-01

    Full Text Available Lead-rich molybdenite is a typical rhenium-bearing molybdenum resource in China, which has not been efficiently utilized due to its high contents of lead and gangue minerals. In this study, hydrochloric acid was used for preliminarily removing lead and calcite from a lead-rich molybdenite concentrate. Oxidative roasting-ammonia leaching was then carried out for separation of rhenium and extraction of molybdenum. The hydrochloric acid leaching experiments revealed that 93.6% Pb and 97.4% Ca were removed when the leaching was performed at 95 °C for 10 min with HCl concentration of 8 wt. % and liquid-solid ratio of 5 (mL/g. The results of direct oxidative roasting indicated that 89.3% rhenium was volatilized from the raw concentrate after roasting at 600 °C for 120 min in air. In contrast, the rhenium volatilization was enhanced distinctly to 98.0% after the acid-leached concentrate (leaching residue was roasted at 550 °C for 100 min. By the subsequent ammonia leaching, 91.5% molybdenum was leached out from the calcine produced from oxidative roasting of the acid-leached concentrate, while only 79.3% Mo was leached from the calcine produced by roasting molybdenite concentrate without pretreatment.

  20. Effect of operational parameters and internal recycle on rhenium solvent extraction from leach liquors using a mixer-settler

    Directory of Open Access Journals (Sweden)

    Mostafa Hosseinzadeh

    2014-06-01

    Full Text Available The extraction of rhenium from molybdenite roasting dust leach solution was performed using a mixer-settler extractor by tributyl phosphate (TBP diluted in kerosene as the extractant. In the single-stage extraction experiments, effect of the aqueous to organic phase ratios, Qa/Qo, and the number of extraction stages, N, on the rhenium extraction was studied. It was found that using the phase ratio of 1:1 in a two-stage extraction, 87.5% depletion of rhenium was obtained. The comparison of experimental results with the continuous co-current extraction showed a good agreement. The effect of internal recycle of organic phase was investigated in the phase ratio of 1:1 by changing the flow rate ratio of recycle-to-fresh organic phase, Qro/Qfo. The optimum performance was achieved in the phase ratio, Qro/Qfo, equal to 3:7. It was found that improvement in the performance of the mixer-settler for the rhenium-TBP system can be obtained in the phase ratio of 1:1when Qro/Qfo = 3:7.

  1. A Study on the Trapping Characteristics of Rhenium Oxide Using Ca(OH){sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tae-Kyo; Eun, Hee-Chul; Choi, Jung-Hoon; Lee, Ki-Rak; Han, Seung-Youb; Park, Hwan-Seo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-01-15

    The objective of this study was to obtain basic data for trapping gaseous technetium (Tc) oxide generated from the voloxidation process in spent nuclear fuel pyroprocessing. Rhenium (Re) and Ca(OH){sub 2} were used as surrogates for the technetium and a trapping material, respectively. The trapping characteristics of rhenium oxide were investigated with changing temperatures and molar ratios of calcium (Ca) over rhenium, and the thermal behaviors of the trapping products were observed. The products following after the trapping test were identified as Ca(ReO{sub 4}){sub 2} and Ca{sub 5}Re{sub 2}O{sub 12}. The conversion to Ca{sub 5}Re{sub 2}O{sub 12} was preferred with increasing temperatures, and the trapping products were completely converted into Ca5Re2O12 under conditions exceeding 800 ℃, or when maintained at 750 ℃ for 4 hr. The trapping efficiency at a molar ratio of 2.5 (Ca:Re=5:2) was significantly superior to that at the molar ratio of 2.

  2. Analysis of extreme ultraviolet spectra from laser produced rhenium plasmas

    Science.gov (United States)

    Wu, Tao; Higashiguchi, Takeshi; Li, Bowen; Suzuki, Yuhei; Arai, Goki; Dinh, Thanh-Hung; Dunne, Padraig; O'Reilly, Fergal; Sokell, Emma; Liu, Luning; O'Sullivan, Gerry

    2015-08-01

    Extreme ultraviolet spectra of highly-charged rhenium ions were observed in the 1-7 nm region using two Nd:YAG lasers with pulse lengths of 150 ps and 10 ns, respectively, operating at a number of laser power densities. The maximum focused peak power density was 2.6 × 1014 W cm-2 for the former and 5.5 × 1012 W cm-2 for the latter. The Cowan suite of atomic structure codes and unresolved transition array (UTA) approach were used to calculate and interpret the emission properties of the different spectra obtained. The results show that n = 4-n = 4 and n = 4-n = 5 UTAs lead to two intense quasi-continuous emission bands in the 4.3-6.3 nm and 1.5-4.3 nm spectral regions. As a result of the different ion stage distributions in the plasmas induced by ps and ns laser irradiation the 1.5-4.3 nm UTA peak moves to shorter wavelength in the ps laser produced plasma spectra. For the ns spectrum, the most populated ion stage during the lifetime of this plasma that could be identified from the n = 4-n = 5 transitions was Re23+ while for the ps plasma the presence of significantly higher stages was demonstrated. For the n = 4-n = 4 4p64dN-4p54dN+1 + 4p64dN-14f transitions, the 4d-4f transitions contribute mainly in the most intense 4.7-5.5 nm region while the 4p-4d subgroup gives rise to a weaker feature in the 4.3-4.7 nm region. A number of previously unidentified spectral features produced by n = 4-n = 5 transitions in the spectra of Re XVI to Re XXXIX are identified.

  3. A new ion source for fission-yield measurements of rare-earth isotopes

    International Nuclear Information System (INIS)

    Pilzer, E.H.; Engler, G.

    1987-01-01

    A new integrated target-ion source for fission-yield measurements of rare-earth isotopes has been developed for the Soreq on-line isotope separator (SOLIS). The source is heated by electron bombardment to a temperature of 2400 0 C and ionization takes place in a rhenium hot cavity. To overcome the problem of impurities which reduce the ionization efficiency, a ZrC disk was inserted in the cavity. Calculations show that because of its high thermionic emission, ZrC enhances ionization performance considerably. For example, in the presence of 10 -5 mbar of cesium impurity, the ionization efficiency of a rhenium hot cavity for the rare-earth terbium is 6%. However, with a ZrC disk, the efficiency increases to 97%. (orig.)

  4. sup(99m)Tc-sulfur-rhenium-colloid and 111In-indiumcitrate in the bone marrow scintigraphy

    International Nuclear Information System (INIS)

    Glaubitt, D.; Haberland, K.; Knoch, K.; Fejer, F.L.; Zachariah, S.; Staedtische Krankenanstalten Krefeld

    1975-01-01

    Bone marrow scintigraphy using 111 In-Indium-citrate and sup(99m)Tc-sulfur rhenium colloid was compared with each other in 6 male and 3 female patients. Our results in all patients were in favour of 111 In-citrate which caused a better delineation of morphological details than sup(99m)Tc-sulfur rhenium colloid did. In the first days after intravenous administration of 111 In-citrate, radioindium accumulated markedly in the pudendal region, this finding being more distinct in male patients than in female ones. On account of these results a considerable radiation dose has to be assumed in bone marrow scintigraphy using 111 In-citrate as long as the absorbed dose from 111 In has not been estimated under consideration of the radioindium accumulation in the pudendal region. 111 In-citrate should be applied in bone marrow scanning only exceptionally and sup(99m)Tc-sulfur rhenium colloid be preferred in the routine diagnostics of bone marrow. (orig.) [de

  5. Therapeutic applications of Rhenium-188 in nuclear medicine and oncology - Current status and expected future perspectives

    International Nuclear Information System (INIS)

    Knapp, F. F. Jr.

    2005-01-01

    Full text: The increasing use of unsealed radioactive targeting agents for cancer treatment requires the routine availability of cost-effective radioisotopes. Rhenium-188 (Re-188; half-life 16.9 hours) is a high-energy beta-emitter (E max 2.12 MeV), readily available no- max carrier-added from the alumina-based tungsten-188 (half-life 69 days)/rhenium-188 generator system. Rhenium-188 also emits a 155 keV (15%) gamma photon, permitting gamma camera imaging for biodistribution and dosimetry evaluation. The versatile chemistry of rhenium allows attachment to a wide variety of targeting molecules for Re-188 applications in nuclear oncology for both palliative metastatic treatment and targeted tumor therapy - radionuclide synovectomy, and coronary restenosis therapy. The long parent half-life and consistent performance provide an indefinite generator shelf-life of several months with high Re-188 elution yields (75-85 %) and consistently low W-188 parent breakthrough ( -6 ). Simple post-elution concentration methods have been developed which provide very high specific volume solution of Re-188 for radiolabeling (> 700 mCi/mL saline/1 Ci generator). Over 60 physician-sponsored clinical trials are currently in progress worldwide with applications in nuclear medicine, nuclear oncology and interventional cardiology. A variety of Re-188-labeled therapeutic radiopharmaceuticals and devices are being developed for clinical trials currently in progress for treatment of both benign and metastatic oncological disorders. Palliation of metastatic bone pain with Re-188-HEDP - prepared from a simple 'kit' - has been demonstrated as a cost-effective alternative to similar agents. Recent studies have in fact demonstrated the enhancement of progression-free interval and survival time by repeated Re-188-HEDP injections to patients with metastatic disease from prostate cancer. The use of the Re-188-labeled antiNCA95 (CD66) antibody in conjunction with external beam irradiation is an

  6. Effect of deformation and annealing on mechanical properties of nickel-rhenium alloys

    International Nuclear Information System (INIS)

    Mashkova, V.M.

    1978-01-01

    Studied have been the mechanical properties of nickel-rhenium alloys, depending on the extent of deformation and heat treatment leading to softening. The mechanical properties of the alloys have been estimated by the results of the tensile tests of wire samples. The softening of the alloy at different temperatures is judged about by the variation in hardness. The results of the study indicate that the most abrupt reduction in the hardness of the cold-hardened metal occurs at 900-1,000 deg C and the hold-time of 1 min. Increase in the hold-time at such temperature almost does not reduce the hardness. It is established that in order to soften nickel-rhenium alloys in the process of the cold-deformation at brief annealings in the air the hold-time should not exceed 5 min at 800-900 deg C

  7. Highvalent and organometallic technetium and rhenium compounds

    International Nuclear Information System (INIS)

    Oehlke, Elisabeth

    2010-01-01

    Diagnostic methods in nuclear medicine allow a detailed description of morphological organ structures and their function. The beta emitting isotope Tc-99 has optimal physical properties (140 keV gamma rays, half-life 6 h) and is therefore used for radiopharmaceuticals. The thesis is concerned with the search for new technetium complexes and their reproducible production. The (TcO3) core is of main interest. The second part of the thesis deals with organometallic technetium and rhenium complexes with carbonyl ligands and N-heterocyclic carbenes that show stability in aerobic aqueous solutions.

  8. Study on the application of crown ether for neutron activation analysis of rubidium and rhenium in rock samples

    International Nuclear Information System (INIS)

    Wang Xiaolin; Fu Yibei; Liu Yinong; Xiong Zonghua; Hao Fanhua

    1996-01-01

    The extraction behaviour of rubidium and rhenium with 18-crown-6 (18C6) and benzo-15-crown-5 (B15C5) in nitrobenzene from picric acid or potassium hydroxide solution are studied and methods for separation and determination are developed. The molar ratio of 18C6 to Rb and B15C5 to Re in the extracted species is probably 2:1. Rubidium and rhenium in rock samples are satisfactorily determined by neutron activation method

  9. Femtosecond Fluorescence and Intersystem Crossing in Rhenium(I) Carbonyl-Bipyridine Complexes

    Czech Academy of Sciences Publication Activity Database

    Cannizzo, A.; Blanco-Rodríguez, A. M.; Nahhas, A. E.; Šebera, Jakub; Záliš, Stanislav; Vlček, Antonín; Chergui, M.

    2008-01-01

    Roč. 130, č. 28 (2008), s. 8967-8974 ISSN 0002-7863 R&D Projects: GA MŠk 1P05OC068 Institutional research plan: CEZ:AV0Z40400503 Keywords : rhenium(I) * carbonyl-bipyridine * intersystem crossing Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 8.091, year: 2008

  10. Molecular Engineering of Technetium and Rhenium Based Radiopharmaceuticals

    International Nuclear Information System (INIS)

    Zubieta, J.

    2003-01-01

    The research was based on the observation that despite the extraordinarily rich coordination chemistry of technetium and rhenium and several notable successes in reagent design, the extensive investigations by numerous research groups on a variety of N 2 S 2 and N 3 S donor type ligands and on HYNIC have revealed that the chemistries of these ligands with Tc and Re are rather complex, giving rise to considerable difficulties in the development of reliable procedures for the development of radiopharmaceutical reagents

  11. Rhenium(V) complexing with benzimidazole in acidic media

    International Nuclear Information System (INIS)

    Zakaeva, R.Sh.; Gagieva, S.Ch.; Kaloev, N.I.; Bukov, N.N.; Panyushkin, V.T.

    2003-01-01

    Coordination compounds of rhenium(V) with 1H-benzimidazole (L) separated from acid media: (HL) 2 [ReOX 5 ](H 2 O) n and [ReOL x X y (H 2 O) z ](H 2 O) n (HL and L - protonated and deprotonated forms of benzimidazole; X = Cl - , Br - ) were studied by the methods of IR spectroscopy, 1 H NMR spectroscopy and thermal gravimetric analysis. Methods of ligand coordination in the complexes are discussed on the basis of data obtained [ru

  12. Fabrication and use of zircaloy/tantalum-sheathed cladding thermocouples and molybdenum/rhenium-sheathed fuel centerline thermocouples

    International Nuclear Information System (INIS)

    Wilkins, S.C.; Sepold, L.K.

    1985-01-01

    The thermocouples described in this report are zircaloy/tantalum-sheathed and molybdenum/rhenium alloy-sheathed instruments intended for fuel rod cladding and fuel centerline temperature measurements, respectively. Both types incorporate beryllium oxide insulation and tungsten/rhenium alloy thermoelements. These thermocouples, operated at temperatures of 2000 0 C and above, were developed for use in the internationally sponsored Severe Fuel Damage test series in the Power Burst Facility. The fabrication steps for both thermocouple types are described in detail. A laser-welding attachment technique for the cladding-type thermocouple is presented, and experience with alternate materials for cladding and fuel therocouples is discussed

  13. Analysis of extreme ultraviolet spectra from laser produced rhenium plasmas

    International Nuclear Information System (INIS)

    Wu, Tao; Dunne, Padraig; O’Reilly, Fergal; Sokell, Emma; Liu, Luning; O’Sullivan, Gerry; Higashiguchi, Takeshi; Suzuki, Yuhei; Arai, Goki; Dinh, Thanh-Hung; Li, Bowen

    2015-01-01

    Extreme ultraviolet spectra of highly-charged rhenium ions were observed in the 1–7 nm region using two Nd:YAG lasers with pulse lengths of 150 ps and 10 ns, respectively, operating at a number of laser power densities. The maximum focused peak power density was 2.6 × 10 14 W cm −2 for the former and 5.5 × 10 12 W cm −2 for the latter. The Cowan suite of atomic structure codes and unresolved transition array (UTA) approach were used to calculate and interpret the emission properties of the different spectra obtained. The results show that n = 4-n = 4 and n = 4-n = 5 UTAs lead to two intense quasi-continuous emission bands in the 4.3–6.3 nm and 1.5–4.3 nm spectral regions. As a result of the different ion stage distributions in the plasmas induced by ps and ns laser irradiation the 1.5–4.3 nm UTA peak moves to shorter wavelength in the ps laser produced plasma spectra. For the ns spectrum, the most populated ion stage during the lifetime of this plasma that could be identified from the n = 4-n = 5 transitions was Re 23+ while for the ps plasma the presence of significantly higher stages was demonstrated. For the n = 4-n = 4 4p 6 4d N -4p 5 4d N+1  + 4p 6 4d N−1 4f transitions, the 4d-4f transitions contribute mainly in the most intense 4.7–5.5 nm region while the 4p-4d subgroup gives rise to a weaker feature in the 4.3–4.7 nm region. A number of previously unidentified spectral features produced by n = 4-n = 5 transitions in the spectra of Re XVI to Re XXXIX are identified. (paper)

  14. Rhenium(V) complexes with sulfur-containing amino acids

    International Nuclear Information System (INIS)

    Gagieva, S.Ch.; Tautieva, M.A.; Tsaloev, A.T.; Galimov, Yu.B.; Gagieva, L.Ch.; Belyaeva, T.N.

    2007-01-01

    Rhenium(V) complexes with 2-amino-4-(methylthio)butanoic acid (methionine, Met) and 2-amino-3-sulfopropionic acid (cysteine, Cys) have been synthesized. Depending on the initial reagent ratio, the resulting complexes contain one or two ligand molecules. On heating the compounds with one amino acid molecule, two hydrogen halide molecules are removed at 128-132 deg C to form a molecular complex. The composition, structure, and thermal stability of the complexes have been studied by elemental analysis, conductometry, IR spectroscopy, NMR, and mass spectrometry [ru

  15. Lattice strains in gold and rhenium under nonhydrostatic compression to 37 GPa

    International Nuclear Information System (INIS)

    Duffy, Thomas S.; Shen, Guoyin; Heinz, Dion L.; Shu, Jinfu; Ma, Yanzhang; Mao, Ho-Kwang; Hemley, Russell J.; Singh, Anil K.

    1999-01-01

    Using energy-dispersive x-ray diffraction techniques together with the theory describing lattice strains under nonhydrostatic compression, the behavior of a layered sample of gold and rhenium has been studied at pressures of 14-37 GPa. For gold, the uniaxial stress component t is consistent with earlier studies and can be described by t=0.06+0.015P where P is the pressure in GPa. The estimated single-crystal elastic moduli are in reasonable agreement with trends based on extrapolated low-pressure data. The degree of elastic anisotropy increases as α, the parameter which characterizes stress-strain continuity across grain boundaries, is reduced from 1.0 to 0.5. For rhenium, the apparent equation of state has been shown to be strongly influenced by nonhydrostatic compression, as evidenced by its dependence on the angle ψ between the diffracting plane normal and the stress axis. The bulk modulus obtained by inversion of nonhydrostatic compression data can differ by nearly a factor of 2 at angles of 0 degree sign and 90 degree sign . On the other hand, by a proper choice of ψ, d spacings corresponding to quasihydrostatic compression can be obtained from data obtained under highly nonhydrostatic conditions. The uniaxial stress in rhenium over the pressure range from 14-37 GPa can be described by t=2.5+0.09P. The large discrepancy between x-ray elastic moduli and ultrasonic data and theoretical calculations indicates that additional factors such as texturing or orientation dependence of t need to be incorporated to more fully describe the strain distribution in hexagonal-close-packed metals. (c) 1999 The American Physical Society

  16. Intracellular distribution and stability of a luminescent rhenium(I) tricarbonyl tetrazolato complex using epifluorescence microscopy in conjunction with X-ray fluorescence imaging

    International Nuclear Information System (INIS)

    Wedding, Jason L.; Harris, Hugh H.; Bader, Christie A.; Plush, Sally E.; Mak, Rachel

    2016-01-01

    Optical fluorescence microscopy was used in conjunction with X-ray fluorescence microscopy to monitor the stability and intracellular distribution of the luminescent rhenium(I) complex fac-[Re(CO) 3 (phen)L], where phen = 1,10-phenathroline and L = 5-(4-iodophenyl)tetrazolato, in 22Rv1 cells. The rhenium complex showed no signs of ancillary ligand dissociation, a conclusion based on data obtained via X-ray fluorescence imaging aligning iodine and rhenium distributions. A diffuse reticular localisation was detected for the complex, in the nuclear/perinuclear region of cells, by either optical or X-ray fluorescence techniques. Furthermore, X-ray fluorescence also showed that the Re-I complex disrupted the homeostasis of some biologically relevant elements, such as chlorine, potassium and zinc.

  17. Effect of the method for rhenium neptasulfide preparation on its catalytic properties in hydrogenation of nitrobenzene and m-nitrobenzoic acid

    International Nuclear Information System (INIS)

    Pal'chevskaya, T.A.; Bogutskaya, L.V.; Belousov, V.M.

    1988-01-01

    The effect of conditions of rhenium heptasulfide synthesis by thiosulfate method on its physicochemical and catalytic properties during hydrogenation of nitrobenzene and m-nitrobenzoic acid has been studied. It is shown that the maximum yield of m-aminobenzoic acid can be attained on insoluble sulfide rhenium contacts, containing excessive amount of sulfur (3.5 %). Under certain conditions of catalyst synthesis particles of Re 2 S 7 soluble in dimethylformamide are formed, which possess selectivity towards amine

  18. Studies of technetium chemistry. Pt.8. The regularities of the bond length and configuration of rhenium and technetium complexes in crystals

    International Nuclear Information System (INIS)

    Liu Guozheng; Liu Boli

    1995-01-01

    Some bond length regularities in MO 6 , MO-4, MX 5 α and MX 4 αβ moieties of technetium and rhenium compounds are summarized and rationalized by cavity model. The chemical properties of technetium and rhenium are so similar that their corresponding complexes have almost the same configuration and M-X bond lengths when they are in cavity-controlled state. Technetium and Rhenium combine preferably with N, O, F, S, Cl and Br when they are in higher oxidation states (>3), but preferably with P, Se etc. when they are in lower oxidation states ( 4 αβ is approximately constant; (2) the average M-X bond length of MX 6 varies moderately with the oxidation state of M; (3) the bond length of M-X trans to M-α in MX 5 α has a linear relationship with the angle

  19. Liquid kit for preparation of 188rhenium-etidronate

    International Nuclear Information System (INIS)

    Marczewski, Barbara; Dias, Carla Roberta; Moraes, Vanessa; Osso Junior, Joao Alberto

    2005-01-01

    The aim of this study was the preparation of a liquid kit for radiolabeling of 188 Re-HEDP (hydroxyethylidene diphosphonate). 188 Re was obtained from alumina based 188 W/ 188 Re generators. This paper reports the efficacy of a cold kit stored for more than two weeks, determined by the dependence of the radiolabeling yields of 188 Re-HEDP on the incubation time, reducing agent concentration, the effects of concentration of ligand, the p H of the reaction and the temperature. The cold kits showed a good stability when carrie-free rhenium-188 was added in the reaction mixture. (author)

  20. Cermets based on rhenium and rare earth element oxides

    International Nuclear Information System (INIS)

    Varfolomeev, M.B.; Velichko, A.V.; Zajtseva, L.L.; Shishkov, N.V.

    1977-01-01

    The reduction of perrhenates of rare earth elements and of yttrium by hydrogen and the subsequent sintering have yielded cermets based on rhenium and rare earth element oxides inherent in which are more disperse and homogeneous structures than those of the ''molecular'' rare earth element-Tc cermets. The dispersity of cermets increases in the rare earth elements series from La to Lu. The microhardness of the Re phase in cermets is 490 kgf/mm 2 ; the total microhardness of a cermet is substantially higher

  1. Endocavitary treatment of craniopharyngioma cysts by 186-rhenium. Traitement endocavitaire par le rhenium 186 des kystes de craniopharyngiomes

    Energy Technology Data Exchange (ETDEWEB)

    Berenger, N.; Lebtahi, R.; Piketty, M.L.; Merienne, L.; Turak, B.; Bok, R.; Askienazy, S. (Hopital Sainte-Anne, 75 - Paris (France)); Munari, C. (Centre Hospitalier Universitaire, 38 - Grenoble (France))

    1993-01-01

    Forty-three patients with craniopharyngioma cysts were treated by intracystic injection of 186-rhenium. Leakage of colloid isotope into the CSF spaces during the ''test'' or ''therapeutic'' injection was detected by scintigraphic follow-up (15 cases/58 intracystic injections). In fact the physical characteristics of [sup 186]Re are well adapted to the requirements of treatment and, with the gamma emission, also allows early detection of leakage, avoiding irradiation of neighbouring structures. Follow-up studies revealed that craniopharyngioma cysts were effectively treated, with cessation of fluid formation, progressive shrinkage of the cysts leading to total disappearance in 14 cases (10-156 months, mean 52.5) and a considerable decrease in 13 cases (5-53 months, mean 23).

  2. Diverse roles of hydrogen in rhenium carbonyl chemistry: hydrides, dihydrogen complexes, and a formyl derivative.

    Science.gov (United States)

    Li, Nan; Xie, Yaoming; King, R Bruce; Schaefer, Henry F

    2010-11-04

    Rhenium carbonyl hydride chemistry dates back to the 1959 synthesis of HRe(CO)₅ by Hieber and Braun. The binuclear H₂Re₂(CO)₈ was subsequently synthesized as a stable compound with a central Re₂(μ-H)₂ unit analogous to the B₂(μ-H)₂ unit in diborane. The complete series of HRe(CO)(n) (n = 5, 4, 3) and H₂Re₂(CO)(n) (n = 9, 8, 7, 6) derivatives have now been investigated by density functional theory. In contrast to the corresponding manganese derivatives, all of the triplet rhenium structures are found to lie at relatively high energies compared with the corresponding singlet structures consistent with the higher ligand field splitting of rhenium relative to manganese. The lowest energy HRe(CO)₅ structure is the expected octahedral structure. Low-energy structures for HRe(CO)(n) (n = 4, 3) are singlet structures derived from the octahedral HRe(CO)₅ structure by removal of one or two carbonyl groups. For H₂Re₂(CO)₉ a structure HRe₂(CO)₉(μ-H), with one terminal and one bridging hydrogen atom, lies within 3 kcal/mol of the structure Re₂(CO)₉(η²-H₂), similar to that of Re₂(CO)₁₀. For H₂Re₂(CO)(n) (n = 8, 7, 6) the only low-energy structures are doubly bridged singlet Re₂(μ-H)₂(CO)(n) structures. Higher energy dihydrogen complex structures are also found.

  3. Complexes of technetium, rhenium, and rhodium with sexidentate Schiff-base ligands

    International Nuclear Information System (INIS)

    Hunter, G.; Kilcullen, N.

    1989-01-01

    The monocationic technetium (IV) and rhenium (IV) complexes with the sexidentate Schiff-base ligands tris[2-(2'-hydroxybenzylideneethyl)]amine and its substituted derivatives have been prepared and their electrochemical properties studied. The variable-temperature 90.6 MHz 13 C-{ 1 H} n.m.r. spectrum of the rhodium (III) complex of tris[2-(2-hydroxy-5'-isopropylbenzylideneethyl)-amine] has been observed, indicating fluxionality at temperatures above 218 K. (author)

  4. Analysis of the Nuclear Structure of Rhenium-186 Using Neutron-Induced Reactions

    Science.gov (United States)

    2015-03-26

    5 1.5 Methods ... radioisotope power source for use on the battlefield. 1 Re-Os Cosmochronometer. The isotope 187Re has a half-life in its ground state of 4.35⇥ 1010 years [2...187Os in meteorites permits one to date the nucleosynthesis of rhenium and osmium by high neutron flux events such as supernovae. The Re-Os radioactive

  5. Rhenium-catalyzed dehydrogenative olefination of C(sp(3))-H bonds with hypervalent iodine(III) reagents.

    Science.gov (United States)

    Gu, Haidong; Wang, Congyang

    2015-06-07

    A dehydrogenative olefination of C(sp(3))-H bonds is disclosed here, by merging rhenium catalysis with an alanine-derived hypervalent iodine(III) reagent. Thus, cyclic and acyclic ethers, toluene derivatives, cycloalkanes, and nitriles are all successfully alkenylated in a regio- and stereoselective manner.

  6. New extraction chromatographic material for rhenium separation

    International Nuclear Information System (INIS)

    Lucanikova, M.; Czech Technical University, Prague; Kucera, J.; Czech Technical University, Prague; Sebesta, F.

    2008-01-01

    Three types of the extraction chromatographic materials, composed from Aliquat R 336 deposited in the polyacrylonitrile (PAN) beads and prepared by different procedures, were compared for extraction of rhenium. The best properties were exhibited when the solid extractant was prepared by impregnation of the ready-made PAN beads. Solid extractant prepared by direct coagulation of the beads from the suspension of Aliquat R 336 in solution of PAN in nitric acid differs only by lower capacity in dynamic conditions. Material prepared from the PAN solution in dimethylsulfoxide was the worst because Aliquat R 336 was washed out from the beads during coagulation of the polymer and the extraction capacity was low. As it is shown, the first two solid extractants are fully comparable with the commercial TEVA Resin. (author)

  7. Synthesis and physicochemical characterization of rhenium (V) complexes with bisbenzoylthiosemicarbazones

    International Nuclear Information System (INIS)

    Gagieva, S.Ch.; Gutnova, N.A.; Tsaloev, A.T.; Khubulov, A.B.; Arutyunyants, A.A.; Galimov, Yu.B.

    2003-01-01

    Rhenium (V) complexing with mono- and bis-benzoylthiosemicarbazones is studied in dependence on hydrohalic acids concentration changes. It is determined that in media with high concentration of hydrohalic acids (6 mol/l HCl, 7 mol/l HBr) in dependence on reaction conditions stable complexes with bi- and tridentate coordination of thiosemicarbazone are formed. In the case of hydrohalic acid concentration decreasing stable binuclear and oxohydroxycomplexes are formed. Composition and structure of the compounds obtained are determined by the methods of element analysis, IR spectroscopy, conductometry. Thermal investigations of the compounds obtained are done [ru

  8. The process development of laser surface modification of commercially pure titanium (Grade 2) with rhenium

    Science.gov (United States)

    Kobiela, K.; Smolina, I.; Dziedzic, R.; Szymczyk, P.; Kurzynowski, T.; Chlebus, E.

    2016-12-01

    The paper presents the results of the process development of laser surface modification of commercially pure titanium with rhenium. The criterion of the successful/optimal process is the repetitive geometry of the surface, characterized by predictable and repetitive chemical composition over its entire surface as well as special mechanical properties (hardness and wear resistance). The analysis of surface geometry concluded measurements of laser penetration depth and heat affected zone (HAZ), the width of a single track as well as width of a clad. The diode laser installed on the industrial robot carried out the laser treatment. This solution made possible the continuous supply of powder to the substrate during the process. The aim of an investigation is find out the possibility of improving the tribological characteristics of the surface due to the rhenium alloying. The verification of the surface properties (tribological) concluded geometry measurements, microstructure observation, hardness tests and evaluation of wear resistance.

  9. Rhenium-186 direct labelling HIgG

    International Nuclear Information System (INIS)

    Lungu, V.; Mihailescu, G.; Dumitrescu, G.

    2001-01-01

    The aim of this study is to develop and improve existing radiolabelling techniques of peptides and monoclonal antibodies with 186 Re for achievement of potential agents for cancer targeted radiotherapy. There were selected methods and techniques for the direct labelling of intact HIgG by studding chemical and radiochemical processes of -S-S- bridges prereduction, reduction of 186 ReO 4 - and coupling reaction of rhenium with HIgG. The -S-S- bridges prereduction of HIgG to sulfhydryls was effected using different reducing agents: ascorbic acid, 2,3 dimercaptopropanol, cysteine, active hydrogen. The prereduction reactions are controlled by masic ratios of HIgG/reduction agent, pH, temperature and time of incubation. A pH=4.5 and a 24 hours incubation time are in the advantage of the prereduction yield. The labelling with 186 Re of prereduced HIgG with ascorbic acid or active hydrogen and 37 deg. C incubation in 22 hours releases 92% radiochemical purity. (author)

  10. IMPROVEMENT OF THE CERN SPS ELECTROSTATIC SEPTA ION TRAPS

    CERN Multimedia

    Balhan, Bruno; Barlow, Roger Andrew; Raffaele, Graziano

    2016-01-01

    At CERN, the SPS synchrotron is equipped with a slow extraction channel towards the fixed target beam lines in the North Area This channel includes five consecutive electrostatic septa, where the field free region and the active high field region are separated by an array of tungsten-rhenium wires. The field-free region provides for the circulating beam, while the high field region is used to deflect the extracted beam. Since the residual gas can be ionized by the orbiting beam, low energy ions could cross the wire array and enter the high field region and cause high voltage breakdown when accelerated onto the cathode. To prevent low energy ions from entering this high electric field region, a vertical field is applied to the orbiting beam using so-called ‘ion traps’ for active protection. The vertical field is created by electrodes placed inside the region containing the circulating beam. Due to electromagnetic coupling onto the ion trap electrodes observed with the high frequency LHC beam (25 ns spaced ...

  11. Liquid kit for preparation of {sup 188}rhenium-etidronate

    Energy Technology Data Exchange (ETDEWEB)

    Marczewski, Barbara; Dias, Carla Roberta; Moraes, Vanessa; Osso Junior, Joao Alberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), SP (Brazil). Centro de Radiofarmacia]. E-mail: baszot@gmail.com

    2005-10-15

    The aim of this study was the preparation of a liquid kit for radiolabeling of {sup 188} Re-HEDP (hydroxyethylidene diphosphonate). {sup 188} Re was obtained from alumina based {sup 188} W/{sup 188} Re generators. This paper reports the efficacy of a cold kit stored for more than two weeks, determined by the dependence of the radiolabeling yields of {sup 188} Re-HEDP on the incubation time, reducing agent concentration, the effects of concentration of ligand, the p H of the reaction and the temperature. The cold kits showed a good stability when carrie-free rhenium-188 was added in the reaction mixture. (author)

  12. Kinetics and mechanism of nitrobenzene hydrogenation to phenylhydroxylamine in rhenium thiocomplexes solutions

    International Nuclear Information System (INIS)

    Korenyako, G.I.; Belousov, V.M.

    1985-01-01

    A study was made on kinetics of nitrobenzene hydrogenation to phenylhydroxylamine in dimethylformamide solutions of rhenium thiocomplexes. The mechanism of hydrogenation was suggested. Formation of hydride catalyst complex represents the first stage of the process. Kinetic equation derived on the basis of suggested mechanism corresponds satisfactorily with experimental results. Thermodynamic parameters of separate process stages calculated on the basis of equilibrium constant values testify as well to the benefit of suggested mechanism

  13. Time-of-flight atom-probe field-ion microscope for the study of defects in metals. Report No. 2357

    International Nuclear Information System (INIS)

    Hall, T.M.; Wagner, A.; Berger, A.S.; Seidman, D.N.

    1975-06-01

    An ultra-high vacuum time-of-flight (TOF) atom-probe field ion microscope (FIM) specifically designed for the study of defects in metals is described. The variable magnification FIM image is viewed with the aid of an internal image intensification system based on a channel electron-multiplier array. The specimen is held in a liquid-helium-cooled goniometer stage, and the specimen is exchanged by means of a high-vacuum (less than 10 -6 torr) specimen exchange device. This stage allows the specimen to be maintained at a tip temperature anywhere in the range from 13 to 450 0 K. Specimens can also be irradiated in-situ with any low-energy (less than 1 keV) gas ion employing a specially constructed ion gun. The pulse-field evaporated ions are detected by a Chevron ion-detector located 2.22 m from the FIM specimen. The TOF of the ions are measured by a specially constructed eight-channel digital timer with a resolution of +-10 ns. The entire process of applying the evaporation pulse to the specimen, measuring the dc and pulse voltages, and analyzing the TOF data is controlled by a NOVA 1220 computer. The computer is also interfaced to a Tektronix graphics terminal which displays the data in the form of a histogram of the number of events versus the mass-to-charge ratio. An extensive set of computer programs to test and operate the atom-probe FIM have been developed. With this automated system we can presently record and analyze 10 TOF s -1 . In the performance tests reported here the instrument has resolved the seven stable isotopes of molybdenum, the five stable isotopes of tungsten, and the two stable isotopes of rhenium in a tungsten--25 at. percent rhenium alloy

  14. Formamidine sulfinic acid as reducing agent in technetium-99m rhenium sulfide labelling

    Energy Technology Data Exchange (ETDEWEB)

    Neves, M; Patricio, L [Laboratorio Nacional de Engenharia e Technologia Industrial, Sacavem (Portugal). Dept. de Radioisotopes; Ferronha, H [Laboratorio Nacional de Investigacao Veterinaria, Lisboa (Portugal)

    1989-08-01

    Labelling kinetic studies, radiochemical characterization and particle size evaluation of {sup 99m}Tc rhenium sulfide colloid using formamidine sulfinic acid as reducing agent are described. Comparison with the same colloid which makes use of Sn-sodium pyrophosphate complex as reducing agent showed higher labelling yields, simplification of labelling procedure and a longer shelf life when formamidine sulfinic acid was used. (author) 15 refs.; 7 figs.

  15. Use of new tandem cation/anion exchange system with clinical-scale generators provides high specific volume solutions of technetium-99m and rhenium-188

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Beets, A.L.; Mirzadeh, S.; Guhlke, S.

    1998-01-01

    In this paper we describe the first application of our simple and inexpensive post-elution tandem cation/anion exchange column system which is based on generator elution with salts of weak acids such as ammonium acetate instead of saline solution to provide very high specific volume solutions of technetium-99m and rhenium-188 from clinical-scale molybdenum-99/technetium-99m generator prepared from low specific activity (n,y) molybdenum-99, and tungsten-188/rhenium-188 generators, respectively. Initial passage of the bolus through a strong cation exchange cartridge converts the ammonium acetate to acetic acid which is essentially not ionized at the acidic pH, allowing specific subsequent amine-type (QMA SepPak TM ) anion exchange cartridge column trapping of the microscopic levels of the pertechnetate or perrhenate. Subsequent elution of the anion cartridge with a small volume ( 500 mCi/mL) from the alumina-based tungsten-188/rhenium-188 generator. (author)

  16. The analysis of mechanism of rhenium-coated tools' wear-resistance rising

    Directory of Open Access Journals (Sweden)

    Daniel Petrosyan

    2017-06-01

    Full Text Available It is proposed to obtain wear-resistant layers on the hard-alloy materials by thermochemical treatment. In the different field of production – mechanical engineering, metallurgy and military technologies, with machine parts demanding high wearproof and corrosion-proof machinery parts on the surfaces of syntheses of diamonds, with metal surface thermal-diffusion with rhenium, to receive diffusion wearing layers for the first time. A method for thermochemical treatment of hard alloy plates has been investigated, allowing to raise the wear-resistance of cutting and mining tools.

  17. Oxidation of iridium coating on rhenium coated graphite at elevated temperature in stagnated air

    International Nuclear Information System (INIS)

    Huang, Yongle; Bai, Shuxin; Zhang, Hong; Ye, Yicong

    2015-01-01

    Highlights: • Continuous and dense Ir coatings were prepared on graphite by electrodepostion. • The purification of the as-prepared Ir coating was higher than about 99.98%. • The Ir/Re/C specimen kept integrity without significant failures after oxidation. • The average oxidation rate of the Ir coating was about 0.219 mg/(cm 2 min). • Penetrating holes at gains boundaries resulted in the failure of the Ir coating. - Abstract: Continuous and dense iridium coatings were prepared on the rhenium coated graphite specimens by electrodeposition. The iridium/rhenium coated graphite (Ir/Re/C) specimens were oxidized at elevated temperatures in stagnated air for 3600 s. The purification of the as-prepared Ir coating was higher than about 99.98% with the main impurity elements Si, Al, Fe and Ru. After oxidation, the Ir/Re/C specimens kept integrity without significant failures and the average oxidation rate was about 0.219 mg/(cm 2 min). Pores were found at the grain boundaries and concentrated to penetrating holes with the growth of Ir grains, which resulted in disastrous failures of the Ir coating

  18. Oxidation of iridium coating on rhenium coated graphite at elevated temperature in stagnated air

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Yongle; Bai, Shuxin, E-mail: NUDT_MSE_501@163.com; Zhang, Hong; Ye, Yicong

    2015-02-15

    Highlights: • Continuous and dense Ir coatings were prepared on graphite by electrodepostion. • The purification of the as-prepared Ir coating was higher than about 99.98%. • The Ir/Re/C specimen kept integrity without significant failures after oxidation. • The average oxidation rate of the Ir coating was about 0.219 mg/(cm{sup 2} min). • Penetrating holes at gains boundaries resulted in the failure of the Ir coating. - Abstract: Continuous and dense iridium coatings were prepared on the rhenium coated graphite specimens by electrodeposition. The iridium/rhenium coated graphite (Ir/Re/C) specimens were oxidized at elevated temperatures in stagnated air for 3600 s. The purification of the as-prepared Ir coating was higher than about 99.98% with the main impurity elements Si, Al, Fe and Ru. After oxidation, the Ir/Re/C specimens kept integrity without significant failures and the average oxidation rate was about 0.219 mg/(cm{sup 2} min). Pores were found at the grain boundaries and concentrated to penetrating holes with the growth of Ir grains, which resulted in disastrous failures of the Ir coating.

  19. High-resolution metallic magnetic calorimeters for β-spectroscopy on 187rhenium and position resolved X-ray spectroscopy

    International Nuclear Information System (INIS)

    Porst, Jan-Patrick

    2011-01-01

    This thesis describes the development of metallic magnetic calorimeters (MMCs) for high resolution spectroscopy. MMCs are energy dispersive particle detectors based on the calorimetric principle which are typically operated at temperatures below 100 mK. The detectors make use of a paramagnetic temperature sensor to transform the temperature rise upon the absorption of a particle in the detector into a measurable magnetic flux change in a dc-SQUID. The application of MMCs for neutrino mass measurements and their advantages with respect to other approaches are discussed. In view of this application the development of an MMC optimized for β-endpoint spectroscopy on 187 rhenium is presented. A fully micro-fabricated X-ray detector is characterized and performs close to design values. Furthermore, a new technique to more efficiently couple rhenium absorbers mechanically and thermally to the sensor was developed and successfully tested. By employing a metallic contact, signal rise times faster than 5 μs could be observed with superconducting rhenium absorbers. In addition to the single pixel detectors, an alternative approach of reading out multiple pixels was developed in this work, too. Here, the individual absorbers have a different thermal coupling to only one temperature sensor resulting in a distribution of different pulse shapes. Straightforward position discrimination by means of rise time analysis is demonstrated for a four pixel MMC and a thermal model of the detector is provided. Unprecedented so far, an energy resolution of less than ΔE FWHM <5 eV for 5.9 keV X-rays was achieved across all absorbers. (orig.)

  20. Mixed moderate thermophilic bioleaching of Cu, Mo and Re from molybdenite concentrate: effects of silver ion, medium and energy sources

    Directory of Open Access Journals (Sweden)

    Hadi Abdollahi

    2017-12-01

    Full Text Available This study evaluates the effects of different additives such as silver ion, medium and energy sources on the efficiency of mixed moderate thermophilic bioleaching approach to extract Cu, Mo and Re from molybdenite concentrate containing 0.98% Cu, 1.56% Fe, 53.84% Mo, and 0.055% Re. Molybdenite was the major phase of Mo-bearing mineral and chalcopyrite, covellite and pyrite were distinguished as minor phases. The higher copper extraction was obtained in tests with silver additives in all types and quantities rather than tests without silver ion. Kinetic of copper dissolution varied in these experiments and depended on the types and amounts of silver, and other supplemented additives such as ferric ion. There was no clear difference in the copper extraction by various culture media and 100% of Cu was dissolved after 30 days of treatment, using 50 mg/L of silver nitrate as additives. In the best condition and without silver additives, maximum 60% of copper was extracted even in the presence of energy sources such as sulfur, ferrous and ferric ions. In the most effective test with initial pH 1.57, 50 mg/L silver nitrate, and 50 g/L ferric sulfate, 100% of copper was dissolved in less than a week with highest kinetics rate. Molybdenum and rhenium extraction had the same tends with redox potential graph. By increasing the redox potential to the 550-600mV, molybdenite started to dissolve and finally, molybdenum and rhenium were extracted 2% and 9.53% in the best condition; respectively.

  1. Studies of the structures of rhenium complexes with sulphur-containing amino acids: cysteine and homocysteine

    International Nuclear Information System (INIS)

    Arkowska, A.; Wojciechowski, W.

    1979-01-01

    Two rhenium compounds have been synthesized: compound 1 with cysteine HS-CH 2 -CH-NH 2 -COOH and compound 2 with homocysteine HS-CH 2 -CH 2 -CH-NH 2 -COOH. On the basis of spectroscopic measurements (IR, far IR, Raman, VIS and UV spectra) and magnetic susceptibility measurements their probable electronic and molecular structures have been determined. (author)

  2. Use of a new tandem cation/anion exchange system with clinical-scale generators provides high specific volume solutions of technetium-99m and rhenium-188

    International Nuclear Information System (INIS)

    Knapp, F.R. Jr.; Beets, A.L.; Mirzadeh, S.; Guhlke, S.; Univ. of Bonn

    1998-03-01

    In this paper the authors describe the first application of a simple and inexpensive post elution tandem cation-anion exchange column system which is based on generator elution with salts of weak acids such as ammonium acetate instead of saline solution to provide very high specific volume solutions of technetium-99m and rhenium-188 from clinical scale molybdenum-99/technetium-99m generator prepared from low specific activity (n,y) molybdenum-99, and tungsten-188/rhenium-188 generators, respectively. Initial passage of the bolus through a strong cation exchange cartridge converts the ammonium acetate to acetic acid which is essentially not ionized at the acidic pH, allowing specific subsequent amine type (QMA SepPak trademark) anion exchange cartridge column trapping of the microscopic levels of the pertechnetate or perrhenate. Subsequent elution of the anion cartridge with a small volume ( 500 mCi/mL) from the alumina-based tungsten-188/rhenium-188 generator

  3. Rhenium (5) and molybdenum (5) complexes with 4',4''(5'')-ditretbutyldibenzo-24-crown-8

    International Nuclear Information System (INIS)

    Ashurova, N.Kh.; Yakubov, K.G.; Basitova, S.M.; Tashmukhamedova, A.K.; Sajfullina, N.Zh.

    1989-01-01

    Rhenium and molybdenum complexes in +5 oxidation degree with 4',4''(5'')-ditretbutyldibenzo-24-crown-8 (L) are synthesized with 75-95 % yield. Composition and structure of compounds produced are investigated using element analysis, conductometry, IR spectroscopy, thermogravimetry methods. Oxidation degree of complexer metal is determined. It is ascertained that the compound composition corresponds to the MOLX 3 formula, where M-Re, Mo; X-Cl - , Br -

  4. Chalcogenhalide cluster rhenium- and molybdenum complexes

    International Nuclear Information System (INIS)

    Fedin, V.P.; Gubin, S.P.; Mishchenko, A.V.; Fedorov, V.E.

    1984-01-01

    The interaction of rhenium- and molybdenum chalcogenhalides with n-donor ligands (L) is studied. At heating Re 3 X 2 Hal 5 complexes up to 100 deg in DMSO in the L presence obtained are the complexes of the 1-6 composition Re 3 X 2 Hal 5 -x Lx DMSO (X=Se, Hal=Cl, L=Et 3 N(1); X=Se, Hal=Cl, L=Bipy(2); X=Se, Hal=Br, L=Et 3 N(3); X=Se, Hal=Br, L=Bipy(4); X=Te, Hal=Br, L=Et 3 N(5); X=Te, Hal=Br, L=(Me 2 NCH 2 ) 2 (6). In the course of boiling of Mo 3 S 7 Hal 4 with PPh 3 in MeCN the Mo 3 S 7 Hal 4 2PPh 3 complexes (Hal=Cl(7); Br(8)) are obtained. For 1 through 8 complexes the chemical analysis data and IR spectra are given. For 4 and 8 complexes the molecular mass is measured. A possible method of obtaining molecular trinuclear clusters from polymer clusters is discussed

  5. Convenient synthesis of bis(alkoxy)rhenium(VII) complexes

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Z.; Al-Ajlouni, A.M.; Espenson, J.H. [Iowa State Univ., Ames, IA (United States)

    1996-02-28

    The study of high-oxidation-state organorhenium compounds has been a field of continuing activity, thanks to the success of methylrhenium trioxide (CH{sub 3}ReO{sub 3} or MTO) in catalytic processes. This catalyst is effective in oxidations, olefin metathesis, the olefination of aldehydes, and the preparation of other compounds with three-membered rings. The syntheses of some rhenium compounds derived form MTO have been reported. Epoxide formation is a key reaction, and it bears directly on these findings reported here. Re(VII) complexes containing a chelated bis(diolate) ligand can be synthesized by refluxing MTO with 2,3-dimethyl-2,3-diol. Here, the authors report a more convenient method for this preparation. A different series of related compounds consists of chelated bis(diolates) of the Cp*Re-oxo series, Cp*ReO-(diolate).

  6. High-resolution metallic magnetic calorimeters for {beta}-spectroscopy on {sup 187}rhenium and position resolved X-ray spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Porst, Jan-Patrick

    2011-02-01

    This thesis describes the development of metallic magnetic calorimeters (MMCs) for high resolution spectroscopy. MMCs are energy dispersive particle detectors based on the calorimetric principle which are typically operated at temperatures below 100 mK. The detectors make use of a paramagnetic temperature sensor to transform the temperature rise upon the absorption of a particle in the detector into a measurable magnetic flux change in a dc-SQUID. The application of MMCs for neutrino mass measurements and their advantages with respect to other approaches are discussed. In view of this application the development of an MMC optimized for {beta}-endpoint spectroscopy on {sup 187}rhenium is presented. A fully micro-fabricated X-ray detector is characterized and performs close to design values. Furthermore, a new technique to more efficiently couple rhenium absorbers mechanically and thermally to the sensor was developed and successfully tested. By employing a metallic contact, signal rise times faster than 5 {mu}s could be observed with superconducting rhenium absorbers. In addition to the single pixel detectors, an alternative approach of reading out multiple pixels was developed in this work, too. Here, the individual absorbers have a different thermal coupling to only one temperature sensor resulting in a distribution of different pulse shapes. Straightforward position discrimination by means of rise time analysis is demonstrated for a four pixel MMC and a thermal model of the detector is provided. Unprecedented so far, an energy resolution of less than {delta}E{sub FWHM}<5 eV for 5.9 keV X-rays was achieved across all absorbers. (orig.)

  7. RHENIUM SOLUBILITY IN BOROSILICATE NUCLEAR WASTE GLASS IMPLICATIONS FOR THE PROCESSING AND IMMOBILIZATION OF TECHNETIUM-99 (AND SUPPORTING INFORMATION WITH GRAPHICAL ABSTRACT)

    Energy Technology Data Exchange (ETDEWEB)

    AA KRUGER; A GOEL; CP RODRIGUEZ; JS MCCLOY; MJ SCHWEIGER; WW LUKENS; JR, BJ RILEY; D KIM; M LIEZERS; P HRMA

    2012-08-13

    The immobilization of 99Tc in a suitable host matrix has proved a challenging task for researchers in the nuclear waste community around the world. At the Hanford site in Washington State in the U.S., the total amount of 99Tc in low-activity waste (LAW) is {approx} 1,300 kg and the current strategy is to immobilize the 99Tc in borosilicate glass with vitrification. In this context, the present article reports on the solubility and retention of rhenium, a nonradioactive surrogate for 99Tc, in a LAW sodium borosilicate glass. Due to the radioactive nature of technetium, rhenium was chosen as a simulant because of previously established similarities in ionic radii and other chemical aspects. The glasses containing target Re concentrations varying from 0 to10,000 ppm by mass were synthesized in vacuum-sealed quartz ampoules to minimize the loss of Re by volatilization during melting at 1000 DC. The rhenium was found to be present predominantly as Re7 + in all the glasses as observed by X-ray absorption near-edge structure (XANES). The solubility of Re in borosilicate glasses was determined to be {approx}3,000 ppm (by mass) using inductively coupled plasma-optical emission spectroscopy (ICP-OES). At higher rhenium concentrations, some additional material was retained in the glasses in the form of alkali perrhenate crystalline inclusions detected by X-ray diffraction (XRD) and laser ablation-ICP mass spectrometry (LA-ICP-MS). Assuming justifiably substantial similarities between Re7 + and Tc 7+ behavior in this glass system, these results implied that the processing and immobilization of 99Tc from radioactive wastes should not be limited by the solubility of 99Tc in borosilicate LAW glasses.

  8. Magnetic interactions in rhenium-containing rare earth double perovskites Sr{sub 2}LnReO{sub 6} (Ln=rare earths)

    Energy Technology Data Exchange (ETDEWEB)

    Nishiyama, Atsuhide; Doi, Yoshihiro; Hinatsu, Yukio, E-mail: hinatsu@sci.hokudai.ac.jp

    2017-04-15

    The perovskite-type compounds containing both rare earth and rhenium Sr{sub 2}LnReO{sub 6} (Ln=Y, Tb-Lu) have been prepared. Powder X-ray diffraction measurements and Rietveld analysis show that Ln{sup 3+} and Re{sup 5+} ions are structurally ordered at the B site of the perovskite SrBO{sub 3}. Magnetic anomalies are found in their magnetic susceptibility and specific heat measurements at 2.6–20 K for Ln=Y, Tb, Dy, Yb, Lu compounds. They are due to magnetic interactions between Re{sup 5+} ions. The results of the magnetic hysteresis and remnant magnetization measurements for Sr{sub 2}YReO{sub 6} and Sr{sub 2}LuReO{sub 6} indicate that the antiferromagnetic interactions between Re{sup 5+} ions below transition temperatures have a weak ferromagnetic component. The analysis of the magnetic specific heat data for Sr{sub 2}YbReO{sub 6} shows that both the Yb{sup 3+} and Re{sup 5+} ions magnetically order at 20 K. For the case of Sr{sub 2}DyReO{sub 6}, magnetic ordering of the Re{sup 5+} moments occurs at 93 K, and with decreasing temperature, the moments of Dy{sup 3+} ferromagnetically order at 5 K from the measurements of magnetic susceptibility and specific heat. - Graphical abstract: Crystal structure of double perovskite Sr{sub 2}LnReO{sub 6}. Red and black lines show cubic and monoclinic unit cells, respectively. - Highlights: • Double perovskites Sr{sub 2}LnReO{sub 6} (Ln=rare earths) were prepared. • They show an antiferromagnetic transition at 2.6–20 K. • In Sr{sub 2}DyReO{sub 6}, Dy and Re moments magnetically order at 5 and 93 K, respectively.

  9. Rhenium Alloys as Ductile Substrates for Diamond Thin-Film Electrodes.

    Science.gov (United States)

    Halpern, Jeffrey M; Martin, Heidi B

    2014-02-01

    Molybdenum-rhenium (Mo/Re) and tungsten-rhenium (W/Re) alloys were investigated as substrates for thin-film, polycrystalline boron-doped diamond electrodes. Traditional, carbide-forming metal substrates adhere strongly to diamond but lose their ductility during exposure to the high-temperature (1000°C) diamond, chemical vapor deposition environment. Boron-doped semi-metallic diamond was selectively deposited for up to 20 hours on one end of Mo/Re (47.5/52.5 wt.%) and W/Re (75/25 wt.%) alloy wires. Conformal diamond films on the alloys displayed grain sizes and Raman signatures similar to films grown on tungsten; in all cases, the morphology and Raman spectra were consistent with well-faceted, microcrystalline diamond with minimal sp 2 carbon content. Cyclic voltammograms of dopamine in phosphate-buffered saline (PBS) showed the wide window and low baseline current of high-quality diamond electrodes. In addition, the films showed consistently well-defined, dopamine electrochemical redox activity. The Mo/Re substrate regions that were uncoated but still exposed to the diamond-growth environment remained substantially more flexible than tungsten in a bend-to-fracture rotation test, bending to the test maximum of 90° and not fracturing. The W/Re substrates fractured after a 27° bend, and the tungsten fractured after a 21° bend. Brittle, transgranular cleavage fracture surfaces were observed for tungsten and W/Re. A tension-induced fracture of the Mo/Re after the prior bend test showed a dimple fracture with a visible ductile core. Overall, the Mo/Re and W/Re alloys were suitable substrates for diamond growth. The Mo/Re alloy remained significantly more ductile than traditional tungsten substrates after diamond growth, and thus may be an attractive metal substrate for more ductile, thin-film diamond electrodes.

  10. Epitaxial growth of rhenium with sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Seongshik [National Institute of Standards and Technology, Boulder, CO 80305 (United States) and Department of Physics, University of Illinois, Urbana, IL 61801 (United States)]. E-mail: soh@boulder.nist.gov; Hite, Dustin A. [National Institute of Standards and Technology, Boulder, CO 80305 (United States); Cicak, K. [National Institute of Standards and Technology, Boulder, CO 80305 (United States); Osborn, Kevin D. [National Institute of Standards and Technology, Boulder, CO 80305 (United States); Simmonds, Raymond W. [National Institute of Standards and Technology, Boulder, CO 80305 (United States); McDermott, Robert [University of California, Santa Barbara, CA 93106 (United States); Cooper, Ken B. [University of California, Santa Barbara, CA 93106 (United States); Steffen, Matthias [University of California, Santa Barbara, CA 93106 (United States); Martinis, John M. [University of California, Santa Barbara, CA 93106 (United States); Pappas, David P. [National Institute of Standards and Technology, Boulder, CO 80305 (United States)

    2006-02-21

    We have grown epitaxial Rhenium (Re) (0001) films on {alpha}-Al{sub 2}O{sub 3} (0001) substrates using sputter deposition in an ultra high vacuum system. We find that better epitaxy is achieved with DC rather than with RF sputtering. With DC sputtering, epitaxy is obtained with the substrate temperatures above 700 deg. C and deposition rates below 0.1 nm/s. The epitaxial Re films are typically composed of terraced hexagonal islands with screw dislocations, and island size gets larger with high temperature post-deposition annealing. The growth starts in a three dimensional mode but transforms into two dimensional mode as the film gets thicker. With a thin ({approx}2 nm) seed layer deposited at room temperature and annealed at a high temperature, the initial three dimensional growth can be suppressed. This results in larger islands when a thick film is grown at 850 deg. C on the seed layer. We also find that when a room temperature deposited Re film is annealed to higher temperatures, epitaxial features start to show up above {approx}600 deg. C, but the film tends to be disordered.

  11. Alkene-glycol interconversion with technetium and rhenium oxo complexes

    International Nuclear Information System (INIS)

    Pearlstein, R.M.; Davison, Alan

    1988-01-01

    The trioxotechnetium(VII) complexes TcO 3 Cl(AA) (AA = phen, bpy, 5-NO 2 -phen, 3,4,7,8-Me 4 -phen) cleanly oxidize olefins (C 2 R 4 ) in solution at 22 0 C, forming in high yields the corresponding oxotechnetium(V) diolate complexes, TcOCl(OCR 2 CR 2 O)(AA). The complexes have been characterized by 1 H NMR, IR, elemental analysis, and fast atom bombardment mass spectrometry. The free diols isolated by hydrolysis of these diolate complexes with HCl were shown by capillary gas chromatography to represent syn addition of the two hydroxyl groups across the double bond. The related rhenium complex, ReOCl(OCH 2 CH 2 O)(phen) undergoes the reverse reaction when thermalized, releasing ethylene and producing ReO 3 Cl(phen). (author)

  12. Broad Detection Range Rhenium Diselenide Photodetector Enhanced by (3-Aminopropyl)Triethoxysilane and Triphenylphosphine Treatment.

    Science.gov (United States)

    Jo, Seo-Hyeon; Park, Hyung-Youl; Kang, Dong-Ho; Shim, Jaewoo; Jeon, Jaeho; Choi, Seunghyuk; Kim, Minwoo; Park, Yongkook; Lee, Jaehyeong; Song, Young Jae; Lee, Sungjoo; Park, Jin-Hong

    2016-08-01

    The effects of triphenylphosphine and (3-aminopropyl)triethoxysilane on a rhenium diselenide (ReSe2 ) photodetector are systematically studied by comparing with conventional MoS2 devices. This study demonstrates a very high performance ReSe2 photodetector with high photoresponsivity (1.18 × 10(6) A W(-1) ), fast photoswitching speed (rising/decaying time: 58/263 ms), and broad photodetection range (possible above 1064 nm). © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Development of pharmaceuticals with radioactive rhenium for cancer therapy. Production of {sup 186}Re and {sup 188}Re, synthesis of labeled compounds and their biodistributions

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    Production of the radioactive rhenium isotopes {sup 186}Re and {sup 188}Re, and synthesis of their labeled compounds have been studied together with the biodistributions of the compounds. This work was carried out by the Working Group on Radioactive Rhenium, consisting of researchers of JAERI and some universities, in the Subcommittee for Production and Radiolabeling under the Consultative Committee of Research on Radioisotopes. For {sup 186}Re, production methods by the {sup 185}Re(n,{gamma}){sup 186}Re reaction in a reactor and by the {sup 186}W(p,n){sup 186}Re reaction with an accelerator, which can produce nocarrier-added {sup 186}Re, have been established. For {sup 188}Re, a production method by the double neutron capture reaction of {sup 186}W, which produces a {sup 188}W/{sup 188}Re generator, has been established. For labeling of bisphosphonate, DMSA, DTPA, DADS, aminomethylenephosphonate and some monoclonal antibodies with the radioactive rhenium isotopes, the optimum conditions, including pH, the amounts of reagents and so on, have been determined for each compound. The biodistributions of each of the labeled compounds in mice have been also obtained. (author)

  14. Design criteria for rhenium-reduced nickel-based single-crystal alloys. Identification and computer-assisted conversion

    International Nuclear Information System (INIS)

    Goehler, Thomas

    2016-01-01

    In the present work, design criteria and property models for the creep strength optimization of rhenium-free nickel based single crystal Superalloys are investigated. The study focuses on a typical load condition of 1050 C and 150 MPa, which is representative for flight engine applications. Thereby the key aspect is to link chemical composition, manufacturing processes, microstructure formation and mechanistic understanding of dislocation creep through a computational materials engineering approach. Beside the positive effect of rhenium on solid solution hardening, a second mechanism in which rhenium increases high temperature creep strength is identified. It indirectly stabilizes precipitation hardening by reducing the coarsening kinetics of γ'-rafting. Five 1st and 2nd generation technical Superalloys show a comparable microstructure evolution for up to 2 % plastic elongation, while creep times differ by a factor of five. The application of a microstructure sensitive creep model shows that these coarsening processes can activate γ-cutting and thus lead to an increasing creep rate. Based on these calculations a threshold value of φ γ/γ' > 2,5 at 150 MPa is estimated. This ratio of matrix channel to raft thickness has been proofed for multiple positions by microstructure analysis of interrupted creep tests. The mechanism described previously can be decelerated by the enrichment of the γ-matrix with slow diffusing elements. The same principle also increases the solid solution strength of the γ-matrix. Therefore, the present work delivers an additional mechanistic explanation why creep properties of single phase nickel based alloys can be transferred to two phase technical Superalloys with rafted γ'-structure. Following, the best way to substitute both rhenium fundamental properties, namely a slow diffusion coefficient and a small solubility in g', has been investigated by means of CALPHAD-modeling. Only molybdenum and especially tungsten

  15. The Influence of Cobalt and Rhenium on the Behaviour of MCrAlY Coatings

    OpenAIRE

    Täck, Ulrike

    2009-01-01

    Superalloys are widely applied as materials for components in the hot section of gas turbines. As superalloys have a limited oxidation life, the application of a coating is vital. The most commonly applied coatings in stationary gas turbines are MCrAlY coatings. Since the turbine components are exposed to high cyclic thermal stresses, MCrAlY coatings must also show a high thermal fatigue resistance. In this thesis, the effect of Cobalt and Rhenium on microstructure, oxidation and thermal fati...

  16. Adsorption and Diffusion of Lithium and Sodium on Defective Rhenium Disulfide: A First Principles Study.

    Science.gov (United States)

    Mukherjee, Sankha; Banwait, Avinav; Grixti, Sean; Koratkar, Nikhil; Singh, Chandra Veer

    2018-02-14

    Single-layer rhenium disulfide (ReS 2 ) is a unique material with distinctive, anisotropic electronic, mechanical, and optical properties and has the potential to be used as an anode in alkali-metal-ion batteries. In this work, first principles calculations were performed to systematically evaluate the potential of monolayer pristine and defective ReS 2 as anodes in lithium (Li)- and sodium (Na)-ion batteries. Our calculations suggest that there are several potential adsorption sites for Li and Na on pristine ReS 2 , owing to its low-symmetry structure. Additionally, the adsorption of Li and Na over pristine ReS 2 is very strong with adsorption energies of -2.28 and -1.71 eV, respectively. Interestingly, the presence of point defects causes significantly stronger binding of the alkali-metal atoms with adsorption energies in the range -2.98 to -3.17 eV for Li and -2.66 to -2.92 eV for Na. Re single vacancy was found to be the strongest binding defect for Li adsorption, whereas S single vacancy was found to be the strongest for Na. The diffusion of these two alkali atoms over pristine ReS 2 is anisotropic, with an energy barrier of 0.33 eV for Li and 0.16 eV for Na. The energy barriers associated with escaping a double vacancy and single vacancy for Li atoms are significantly large at 0.60 eV for the double-vacancy case and 0.51 eV for the single-vacancy case. Similarly, for Na, they are 0.59 and 0.47 eV, respectively, which indicates slower migration and sluggish charging/discharging. However, the diffusion energy barrier over a Re single vacancy is found to be merely 0.42 eV for a Li atom and 0.28 eV for Na. Overall, S single and double vacancies can reduce the diffusion rate by 10 3 -10 5 times for Li and Na ions, respectively. These results suggest that monolayer ReS 2 with a Re single vacancy adsorbs Li and Na stronger than pristine ReS 2 , with negligible negotiation with the charging/discharging rate of the battery, and therefore they can be used as an anode

  17. Fate of rhenium in the environment as a chemical analogue of technetium

    International Nuclear Information System (INIS)

    Tagami, Keiko; Uchida, Shigeo

    2007-01-01

    Concentrations of rhenium, a chemical analogue of Tc, were measured in various environmental samples by ICP-MS to obtain information values on long-lived 99 Tc mobility in the environment. From the results, it was assumed that Re was removed from the rock and soil by water due to weathering and transport to the sea through rivers. The element would be retained in seawater for a long time, i.e., 2 x 10 5 to 7.5 x 10 5 y. The reservoirs of Re in the sea would be seaweeds, and anoxic and suboxic sediments, especially slightly below the water-sediment interface. (author)

  18. Hot rocket plume experiment - Survey and conceptual design. [of rhenium-iridium bipropellants

    Science.gov (United States)

    Millard, Jerry M.; Luan, Taylor W.; Dowdy, Mack W.

    1992-01-01

    Attention is given to a space-borne engine plume experiment study to fly an experiment which will both verify and quantify the reduced contamination from advanced rhenium-iridium earth-storable bipropellant rockets (hot rockets) and provide a correlation between high-fidelity, in-space measurements and theoretical plume and surface contamination models. The experiment conceptual design is based on survey results from plume and contamination technologists throughout the U.S. With respect to shuttle use, cursory investigations validate Hitchhiker availability and adaptability, adequate remote manipulator system (RMS) articulation and dynamic capability, acceptable RMS attachment capability, adequate power and telemetry capability, and adequate flight altitude and attitude/orbital capability.

  19. Issues associated with the use of the Tungsten-188/Rhenium188 generator and concentrator system and preparation of Re-188 HDD: A report

    International Nuclear Information System (INIS)

    Knapp, F.F.Jr.; Turner, J.H.; Jeong, J.-M.; Padhy, A.K.

    2004-01-01

    The ready availability of no-carrier-added Rhenium-188 from the Tungsten-188/Rhenium-188 generator represents an important source of a therapeutic radioisotope for a broad range of therapeutic applications in nuclear medicine, oncology, rheumatology and interventional cardiology. The International Atomic Energy Agency (IAEA) is coordinating a clinical trial involving the use of Rhenium188-Lipiodol for therapy of hepatocellular carcinoma. This report summarizes the experience of investigators at ten participating centres associated with the use and performance of the Tungsten-188/Rhenium-188 generators and the preparation and handling of the Re-188 HDD agent. This evaluation has demonstrated the cost effective provision of on-site therapeutic activities of Rhenium-188 and recommendations are made for further development of the next generator prototype in light of this international experience. The high bolus volumes (20-40 ml) of the ORNL generator requires post elution concentration of the Re-188 bolus by passage through the tandem silver cation/anion column system. The high back pressure often encountered during generator elution through the silver cation/anion concentrator system has been identified as a potential problem. The details of a method involving in house preparation of the silver cation columns were provided and implementation of this method for Re-188 bolus concentration is recommended. It is also recommended that ORNL investigators reassess the possibility of increasing Tungsten generator loading capacity and the use of higher specific activity Tungsten-188, with a view to reducing the generator bolus volume. The Re-188 HDD/Lipiodol conjugate?;ate is used in this IAEA trial for radioembolytic therapy of primary liver cancer, and methods for preparation of Re-188 HDD and its extraction into Lipiodol are discussed. Since Re-188 HDD binds to glass surfaces, the recovery yields are variable and can be as low as 40-45%. In an effort to maximize the

  20. Rhenium(5) and molybdenum(5) complexes with 4',4(5)-divaleryldibenzo-18-crown-6

    International Nuclear Information System (INIS)

    Ashurova, N.Kh.; Yakubov, K.G.; Tashmukhamedova, A.K.; Basitova, S.M.

    1993-01-01

    Methods for synthesizing oxohalide complexes of rhenium and molybdenum with +5 oxidation degree with 4',4 (5) -divaleryldibenzo-18-crown-6 were developed. Content and composition of prepared compounds were investigated by the methods of element analysis, crystal optics, conductometry, IR spectroscopy in the near and far regions, thermogravimetry. Oxidation degree of the complex-forming metal was determined. It was established that composition of the compounds coressponded to the general formula MOLX · H 2 O, where M - Re, Mo; L -4',4 (5) -divaleryldibenzo-18-crown-6; X -Cl - , Br -

  1. Rhenium Dichalcogenides: Layered Semiconductors with Two Vertical Orientations.

    Science.gov (United States)

    Hart, Lewis; Dale, Sara; Hoye, Sarah; Webb, James L; Wolverson, Daniel

    2016-02-10

    The rhenium and technetium diselenides and disulfides are van der Waals layered semiconductors in some respects similar to more well-known transition metal dichalcogenides (TMD) such as molybdenum sulfide. However, their symmetry is lower, consisting only of an inversion center, so that turning a layer upside-down (that is, applying a C2 rotation about an in-plane axis) is not a symmetry operation, but reverses the sign of the angle between the two nonequivalent in-plane crystallographic axes. A given layer thus can be placed on a substrate in two symmetrically nonequivalent (but energetically similar) ways. This has consequences for the exploitation of the anisotropic properties of these materials in TMD heterostructures and is expected to lead to a new source of domain structure in large-area layer growth. We produced few-layer ReS2 and ReSe2 samples with controlled "up" or "down" orientations by micromechanical cleavage and we show how polarized Raman microscopy can be used to distinguish these two orientations, thus establishing Raman as an essential tool for the characterization of large-area layers.

  2. Superhard Rhenium/Tungsten Diboride Solid Solutions.

    Science.gov (United States)

    Lech, Andrew T; Turner, Christopher L; Lei, Jialin; Mohammadi, Reza; Tolbert, Sarah H; Kaner, Richard B

    2016-11-02

    Rhenium diboride (ReB 2 ), containing corrugated layers of covalently bonded boron, is a superhard metallic compound with a microhardness reaching as high as 40.5 GPa (under an applied load of 0.49 N). Tungsten diboride (WB 2 ), which takes a structural hybrid between that of ReB 2 and AlB 2 , where half of the boron layers are planar (as in AlB 2 ) and half are corrugated (as in ReB 2 ), has been shown not to be superhard. Here, we demonstrate that the ReB 2 -type structure can be maintained for solid solutions of tungsten in ReB 2 with tungsten content up to a surprisingly large limit of nearly 50 atom %. The lattice parameters for the solid solutions linearly increase along both the a- and c-axes with increasing tungsten content, as evaluated by powder X-ray and neutron diffraction. From micro- and nanoindentation hardness testing, all of the compositions within the range of 0-48 atom % W are superhard, and the bulk modulus of the 48 atom % solid solution is nearly identical to that of pure ReB 2 . These results further indicate that ReB 2 -structured compounds are superhard, as has been predicted from first-principles calculations, and may warrant further studies into additional solid solutions or ternary compounds taking this structure type.

  3. Development of a radiochemical neutron activation analysis procedure for determination of rhenium in biological and environmental samples at ultratrace level

    Czech Academy of Sciences Publication Activity Database

    Kučera, Jan; Byrne, A. R.; Mizera, Jiří; Lučaníková, M.; Řanda, Zdeněk

    2006-01-01

    Roč. 269, č. 2 (2006), s. 251-257 ISSN 0236-5731 R&D Projects: GA ČR(CZ) GA203/04/0943 Institutional research plan: CEZ:AV0Z10480505 Keywords : radiochemical neutron activation analysis * rhenium * biological and environmental samples Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 0.509, year: 2006

  4. Crystal structures of a manganese(I and a rhenium(I complex of a bipyridine ligand with a non-coordinating benzoic acid moiety

    Directory of Open Access Journals (Sweden)

    Sheri Lense

    2018-05-01

    Full Text Available The structures of two facially coordinated Group VII metal complexes are reported, namely: fac-bromido[2-(2,2′-bipyridin-6-ylbenzoic acid-κ2N,N′]tricarbonylmanganese(I tetrahydrofuran monosolvate, [MnBr(C17H12N2O2(CO3]·C4H8O, I, and fac-[2-(2,2′-bipyridin-6-ylbenzoic acid-κ2N,N′]tricarbonylchloridorhenium(I tetrahydrofuran monosolvate, [ReCl(C17H12N2O2(CO3]·C4H8O, II. In both complexes, the metal ion is coordinated by three carbonyl ligands, a halide ion, and a 2-(2,2′-bipyridin-6-ylbenzoic acid ligand, in a distorted octahedral geometry. In manganese complex I, the tetrahydrofuran (THF solvent molecule could not be refined due to disorder. The benzoic acid fragment is also disordered over two positions, such that the carboxylic acid group is either positioned near to the bromide ligand or to the axial carbonyl ligand. In the crystal of I, the complex molecules are linked by a pair of C—H...Br hydrogen bonds, forming inversion dimers that stack up the a-axis direction. In the rhenium complex II, there is hydrogen bonding between the benzoic acid moiety and a disordered co-crystallized THF molecule. In the crystal, the molecules are linked by C—H...Cl hydrogen bonds, forming layers parallel to (100 separated by layers of THF solvent molecules.

  5. Photocatalytic Conversion of CO2 to CO using Rhenium Bipyridine Platforms Containing Ancillary Phenyl or BODIPY Moieties

    Science.gov (United States)

    Andrade, Gabriel A.; Pistner, Allen J.; Yap, Glenn P.A.; Lutterman, Daniel A.; Rosenthal, Joel

    2013-01-01

    Harnessing of solar energy to drive the reduction of carbon dioxide to fuels requires the development of efficient catalysts that absorb sunlight. In this work, we detail the synthesis, electrochemistry and photophysical properties of a set of homologous fac-ReI(CO)3 complexes containing either an ancillary phenyl (8) or BODIPY (12) substituent. These studies demonstrate that both the electronic properties of the rhenium center and BODIPY chromophore are maintained for these complexes. Photolysis studies demonstrate that both assemblies 8 and 12 are competent catalysts for the photochemical reduction of CO2 to CO in DMF using triethanolamine (TEOA) as a sacrificial reductant. Both compounds 8 and 12 display TOFs for photocatalytic CO production upon irradiation with light (λex ≥ 400 nm) of ~5 hr−1 with TON values of approximately 20. Although structural and photophysical measurements demonstrate that electronic coupling between the BODIPY and fac-ReI(CO)3 units is limited for complex 12, this work clearly shows that the photoactive BODIPY moiety is tolerated during catalysis and does not interfere with the observed photochemistry. When taken together, these results provide a clear roadmap for the development of advanced rhenium bipyridine complexes bearing ancillary BODIPY groups for the efficient photocatalytic reduction of CO2 using visible light. PMID:24015374

  6. Rhenium and technetium complexes with phenylbis(2-pyridyl)phosphine and tris(2-pyridyl)phosphine

    Energy Technology Data Exchange (ETDEWEB)

    Saucedo A, S. A. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Hagenbach, A.; Abram, U., E-mail: ssaucedo@uaz.edu.m [Institut fur Chemie und Biochemie, Freie Universitat Berlin, Fabeckstr. 34-36, D-14195, Berlin (Germany)

    2010-10-15

    Reactions of common technetium and rhenium precursors with 2-pyridyl phosphines produce novel, air stable tricarbonyl and oxo complexes. (NEt{sub 4}){sub 2}[Re(CO){sub 3}Br{sub 3}] or (NEt{sub 4}){sub 2}[Tc(CO){sub 3}Cl{sub 3}] react with phenylbis(2-pyridyl)phosphine (PPhpy{sub 2}) or tris(2-pyridyl)phosphine (Ppy{sub 3}) under formation of neutral tricarbonyl complexes of the composition [M(CO){sub 3}X(L)] (M = Re, X = Br; M = Tc, X = Cl, L = PPhpy{sub 2} or Ppy{sub 3}), where the ligands coordinate only with two for their nitrogen atoms. Removal of the bromo ligands from (NEt{sub 4}){sub 2}[Re(CO){sub 3}(Br){sub 3}] with AgNO{sub 3}, to force a tripodal coordination, and the subsequent reaction with the Ppy{sub 3} results in the formation of the complex [Re(CO){sub 3}(NO{sub 3})(Ppy{sub 3}{sup -}N,N{sup '})] with a monodentate coordinated nitrato ligand. (NBu{sub 4})[ReOCl{sub 4}] reacts with PPhpy{sub 2} to give the asymmetric, oxo-bridged rhenium (V) dimer (NBu{sub 4})[Re{sub 2}O{sub 2}Cl{sub 5}({mu}-PPhpy{sub 2}{sup -}P,N,N,N{sup '})({mu}-O)], while a similar reaction with (ReOCl{sub 3}(PPh{sub 3}){sub 2}] in boiling Thf results in reduction of the metal and gives (ReCl{sub 3}(OPPhpy{sub 2})(PPh{sub 3})]. The products have been characterized spectroscopically and by X-ray structure analyses. (Author)

  7. Click-to-Chelate: Development of Technetium and Rhenium-Tricarbonyl Labeled Radiopharmaceuticals

    Directory of Open Access Journals (Sweden)

    Thomas L. Mindt

    2013-03-01

    Full Text Available The Click-to-Chelate approach is a highly efficient strategy for the radiolabeling of molecules of medicinal interest with technetium and rhenium-tricarbonyl cores. Reaction of azide-functionalized molecules with alkyne prochelators by the Cu(I-catalyzed azide-alkyne cycloaddition (CuAAC; click reaction enables the simultaneous synthesis and conjugation of tridentate chelating systems for the stable complexation of the radiometals. In many cases, the functionalization of (biomolecules with the ligand system and radiolabeling can be achieved by convenient one-pot procedures. Since its first report in 2006, Click-to-Chelate has been applied to the development of numerous novel radiotracers with promising potential for translation into the clinic. This review summarizes the use of the Click-to-Chelate approach in radiopharmaceutical sciences and provides a perspective for future applications.

  8. Catalytic transformation of functionalized carboxylic acids using multifunctional rhenium complexes.

    Science.gov (United States)

    Naruto, Masayuki; Agrawal, Santosh; Toda, Katsuaki; Saito, Susumu

    2017-06-13

    Carboxylic acids (CAs) are one of the most ubiquitous and important chemical feedstocks available from biorenewable resources, CO 2 , and the petrochemical industry. Unfortunately, chemoselective catalytic transformations of CH n CO 2 H (n = 1-3) groups into other functionalities remain a significant challenge. Herein, we report rhenium V complexes as extremely effective precatalysts for this purpose. Compared to previously reported heterogeneous and homogeneous catalysts derived from high- or low-valent metals, the present method involves a α-C-H bond functionalization, a hydrogenation, and a hydrogenolysis, which affords functionalized alcohols with a wide substrate scope and high chemoselectivity under relatively mild reaction conditions. The results represent an important step toward a paradigm shift from 'low-valent' to 'high-valent' metal complexes by exploring a new portfolio of selective functional group transformations of highly oxygenated organic substrates, as well as toward the exploitation of CAs as a valuable biorenewable feedstock.

  9. Solid-state thermolysis of a fac-rhenium(I) carbonyl complex with a redox non-innocent pincer ligand.

    Science.gov (United States)

    Jurca, Titel; Chen, Wen-Ching; Michel, Sheila; Korobkov, Ilia; Ong, Tiow-Gan; Richeson, Darrin S

    2013-03-25

    The development of rhenium(I) chemistry has been restricted by the limited structural and electronic variability of the common pseudo-octahedral products fac-[ReX(CO)3L2] (L2 = α-diimine). We address this constraint by first preparing the bidentate bis(imino)pyridine complexes [(2,6-{2,6-Me2C6H3N=CPh}2C5H3N)Re(CO)3X] (X = Cl 2, Br 3), which were characterized by spectroscopic and X-ray crystallographic means, and then converting these species into tridentate pincer ligand compounds, [(2,6-{2,6-Me2C6H3N=CPh}2C5H3N)Re(CO)2X] (X = Cl 4, Br 5). This transformation was performed in the solid-state by controlled heating of 2 or 3 above 200 °C in a tube furnace under a flow of nitrogen gas, giving excellent yields (≥95 %). Compounds 4 and 5 define a new coordination environment for rhenium(I) carbonyl chemistry where the metal center is supported by a planar, tridentate pincer-coordinated bis(imino)pyridine ligand. The basic photophysical features of these compounds show significant elaboration in both number and intensity of the d-π* transitions observed in the UV/Vis spec tra relative to the bidentate starting materials, and these spectra were analyzed using time-dependent DFT computations. The redox nature of the bis(imino)pyridine ligand in compounds 2 and 4 was examined by electrochemical analysis, which showed two ligand reduction events and demonstrated that the ligand reduction shifts to a more positive potential when going from bidentate 2 to tridentate 4 (+160 mV for the first reduction step and +90 mV for the second). These observations indicate an increase in electrostatic stabilization of the reduced ligand in the tridentate conformation. Elaboration on this synthetic methodology documented its generality through the preparation of the pseudo-octahedral rhenium(I) triflate complex [(2,6-{2,6-Me2C6H3N=CPh}2C5H3N)Re(CO)2OTf] (7, 93 % yield). Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Experimental determination of the hydrothermal solubility of ReS2 and the Re–ReO2 buffer assemblage and transport of rhenium under supercritical conditions

    Directory of Open Access Journals (Sweden)

    Wood Scott A

    2002-01-01

    Full Text Available To understand the aqueous species important for transport of rhenium under supercritical conditions, we conducted a series of solubility experiments on the Re–ReO2 buffer assemblage and ReS2. In these experiments, pH was buffered by the K–feldspar–muscovite–quartz assemblage; in sulfur-free systems was buffered by the Re–ReO2 assemblage; and and in sulfur-containing systems were buffered by the magnetite–pyrite–pyrrhotite assemblage. Our experimental studies indicate that the species ReCl40 is dominant at 400°C in slightly acidic to near-neutral, and chloride-rich (total chloride concentrations ranging from 0.5 to 1.0 M environments, and ReCl3+ may predominate at 500°C in a solution with total chloride concentrations ranging from 0.5 to 1.5 M. The results also demonstrate that the solubility of ReS2 is about two orders of magnitude less than that of ReO2. This finding not only suggests that ReS2 (or a ReS2 component in molybdenite is the solubility-controlling phase in sulfur-containing, reducing environments but also implies that a mixing process involving an oxidized, rhenium-containing solution and a solution with reduced sulfur is one of the most effective mechanisms for deposition of rhenium. In analogy with Re, TcS2 may be the stable Tc-bearing phase in deep geological repositories of radioactive wastes.

  11. Tracing oxidative weathering from the Andes to the lowland Amazon Basin using dissoved rhenium

    Science.gov (United States)

    Dellinger, M.; Hilton, R. G.; West, A. J.; Torres, M.; Burton, K. W.; Clark, K. E.; Baronas, J. J.

    2016-12-01

    Over long timescales (>105 yrs), the abundance of carbon dioxide (CO2) in the atmosphere is determined by the balance of the major carbon sources and sinks. Among the major carbon sources, the oxidation of organic carbon contained within sedimentary rocks ("petrogenic" carbon, or OCpetro) is thought to result in CO2 emission of similar magnitude to that released by volcanism. Rhenium (Re) has been proposed as a proxy for tracing OCpetro oxidation. Here we investigate the source, behavior and flux of dissolved and particulate rhenium (Re) in the Madre de Dios watershed (a major Andean tributary of the Amazon River) and the lowlands, aiming to characterize the behavior of Re in river water and quantify the flux of CO2 released by OCpetro oxidation. Measured Re concentrations in Andean rivers range from 0.07 to 1.55 ppt. In the Andes, Re concentration do not change significantly with water discharge, whereas in the lowlands, Re concentration decrease at high water discharge. Mass balance calculation show that more than 70% of the dissolved Re is sourced from the oxidation of OCpetro the Andes-floodplain system. We calculate dissolved Re flux over a hydrological year to estimate the rates of oxidative weathering, and the associated CO2 release from OCpetro. Rates are high in the Andean headwaters, consistent with estimates from other mountain rivers with similar rates of physical erosion. We find evidence that a significant amount of additional oxidation (Re flux) happens during floodplain transport. These results have important implications for improving our understanding of the source and processes controlling Re in rivers, and allowing us to quantify long-term OCpetro cycling in large river basins.

  12. Effect of rhenium and osmium on mechanical properties of a 9Cr-2W-0.25V-0.07Ta-0.1C steel

    International Nuclear Information System (INIS)

    Klueh, R.L.; Alexander, D.J.; Sokolov, M.A.

    2000-01-01

    The nuclear transmutation of tungsten to rhenium and osmium in a tungsten-containing steel irradiated in a fission or fusion reactor will change the chemical composition of the steel. To determine the possible consequences of such compositional changes on the mechanical properties, tensile and Charpy impact properties were measured on five 9Cr-2W-0.25V-0.07Ta-0.1C steels that contained different amounts of rhenium, osmium, and tungsten. The mechanical properties changes caused by these changes in composition were minor. Observations were also made on the effect of carbon concentration. The effect of carbon on tensile behavior was minor, but there was a large effect on Charpy properties. Several of the steels showed little effect of tempering temperature on the Charpy transition temperature, a behavior that was tentatively attributed to the low silicon and/or manganese concentration of the experimental steels

  13. Absorption behavior of technetium and rhenium through plant roots

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.

    2004-01-01

    The absorption behavior of technetium (Tc) and rhenium (Re) through plant roots was studied using nutrient solution culture. Radish samples, grown in culture solutions for 20-30 days in a green house, were transferred into plastic vessels containing nutrient solutions contaminated with multi-tracer solutions including Tc-95m and Re-183. The plant samples were grown individually for 1-7 days under laboratory conditions. The activities of radionuclides in nutrient solutions and oven-dried plant parts (roots, fleshy roots and leaves) were measured with Ge detecting systems. The concentrations of Tc-95m and Re-183 in the nutrient solutions after harvesting the plants were almost the same as those in the initial solution. Possibly, the radionuclides were taken up with water through plant roots. The distributions of Tc and Re in the plants showed no differences, thus, soluble Tc and Re absorption by plant samples were the same. It is suggested that Re could be used as a geochemical tracer of Tc in the soil environment. (author)

  14. A tungsten-rhenium interatomic potential for point defect studies

    Science.gov (United States)

    Setyawan, Wahyu; Gao, Ning; Kurtz, Richard J.

    2018-05-01

    A tungsten-rhenium (W-Re) classical interatomic potential is developed within the embedded atom method interaction framework. A force-matching method is employed to fit the potential to ab initio forces, energies, and stresses. Simulated annealing is combined with the conjugate gradient technique to search for an optimum potential from over 1000 initial trial sets. The potential is designed for studying point defects in W-Re systems. It gives good predictions of the formation energies of Re defects in W and the binding energies of W self-interstitial clusters with Re. The potential is further evaluated for describing the formation energy of structures in the σ and χ intermetallic phases. The predicted convex-hulls of formation energy are in excellent agreement with ab initio data. In pure Re, the potential can reproduce the formation energies of vacancies and self-interstitial defects sufficiently accurately and gives the correct ground state self-interstitial configuration. Furthermore, by including liquid structures in the fit, the potential yields a Re melting temperature (3130 K) that is close to the experimental value (3459 K).

  15. Rhenium(V) and technetium(V) complexes of bis(o-hydroxyphenyl)phenylphosphine (PO22-) and (o-hydroxyphenyl)diphenylphosphine (PO-) ligands

    International Nuclear Information System (INIS)

    Luo, Hongyan; Setyawati, Ika; Rettig, S.J.; Orvig, C.

    1995-01-01

    The synthesis of several phosphine-based chelating compounds and chelates formed between these compounds and rhenium or technetium is discussed. Four categories of products result, (i) bis-(o-hydroxyphenyl) diphenylphosphine (PO) complexes, (ii) mono- (PO) complexes, (iii) bis-bis(o-hydroxyphenyl)-phenylphosphine (PO 2 ) complexes, and mixed-(PO) and (PO 2 ) complexes. Molecular structures of these compounds (including isomers) were probed by NMR, MS, and IR spectroscopies and by X-ray crystallography

  16. Ultrafast Excited-State Dynamics of Rhenium(I) Photosensitizers [Re(Cl)(CO)3(N,N)] and [Re(imidazole)(CO)3(N,N)]+: Diimine Effects

    Czech Academy of Sciences Publication Activity Database

    Nahhas, A. E.; Consani, C.; Blanco-Rodríguez, A. M.; Lancaster, K. M.; Braem, O.; Cannizzo, A.; Towrie, M.; Clark, I. P.; Záliš, Stanislav; Chergui, M.; Vlček, Antonín

    2011-01-01

    Roč. 50, č. 7 (2011), s. 2932-2943 ISSN 0020-1669 R&D Projects: GA MŠk(CZ) ME10124; GA MŠk(CZ) LD11082 Institutional research plan: CEZ:AV0Z40400503 Keywords : rhenium * photosynthesis * diimine effects Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 4.601, year: 2011

  17. Rhenium-188: Availability from the W-188/Re-188 Generator and Status of Current Applications

    International Nuclear Information System (INIS)

    Pillai, M.R.A.; Dash, A.; Knapp, Russ F. Jr.

    2012-01-01

    Rhenium-188 is one of the most readily available generator derived and useful radionuclides for therapy emitting β-particles (2.12 MeV, 71.1% and 1.965 MeV, 25.6%) and imageable gammas (155 KeV, 15.1%). The 188W/188Re generator is an ideal source for the long term (4-6 months) continuous availability of no carrier added (nca) 188Re suitable for the preparation of radiopharmaceuticals for radionuclide therapy. The challenges associated with the double neutron capture route of production of the parent 188W radionuclide have been a major impediment in the progress of application of 188Re. Tungsten-188 of adequate specific activity can be prepared only in 2-3 of the high flux reactors operating in the World. Several useful technologies have been developed for the preparation of clinical grade 188W/188Re generator. Since the specific activity of 188W used in the generator is relatively low (<5 Ci/g), the eluted 188ReO4- can have low radioactive concentration often insufficient for radiopharmaceutical preparation. However, several efficient post elution concentration techniques have been developed that yield clinically useful 188ReO4-. Rhenium-188 has been used for the preparation of therapeutic radiopharmaceuticals for the management of diseases such as bone metastasis, rheumatoid arthritis and primary cancers. Several early phase clinical studies using radiopharmaceuticals based on 188Re-labeled phosphonates, antibodies, peptides, lipiodol and particulates have been reported. This article reviews the availability, and use of188Re including a discussion of why broader use of 188Re has not progressed as ecpected as a popular radionuclide for therapy.

  18. Synthesis, characterization, and photophysical properties of a thiophene-functionalized bis(pyrazolyl) pyridine (BPP) tricarbonyl rhenium(I) complex.

    Science.gov (United States)

    Lytwak, Lauren A; Stanley, Julie M; Mejía, Michelle L; Holliday, Bradley J

    2010-09-07

    A bromo tricarbonyl rhenium(I) complex with a thiophene-functionalized bis(pyrazolyl) pyridine ligand (L), ReBr(L)(CO)(3) (1), has been synthesized and characterized by variable temperature and COSY 2-D (1)H NMR spectroscopy, single-crystal X-ray diffraction, and photophysical methods. Complex 1 is highly luminescent in both solution and solid-state, consistent with phosphorescence from an emissive (3)MLCT excited state with an additional contribution from a LC (3)(pi-->pi*) transition. The single-crystal X-ray diffraction structure of the title ligand is also reported.

  19. Evaluation of a new component used for isotopic lymphography: colloidal rhenium sulfide sup(99m)Tc labelled

    International Nuclear Information System (INIS)

    Pecking, A.; Le Mercier, N.; Gobin, R.; Bardy, A.; Najean, Y.

    1978-01-01

    We have studied for lymphatic scintigraphy a new radiopharmaceutical, sup(99m)Tc-labelled rhenium sulfocolloid. This preliminary study includes 20 adults patients with lymphomas and lymphoedemas. The principal advantage of this drug is its absence of toxicity and local pain, so that a rapid sub-cutaneous injection without local anesthesia is made possible. Good results have been obtained, as well in morphological studies of para-aortic and mammary lymph nodes as for kinetic studies of lymphatic flow in lymphoedemas. No liver and spleen uptake of radio-isotope was observed after foot injection [fr

  20. Polymer Photovoltaic Cells with Rhenium Oxide as Anode Interlayer.

    Science.gov (United States)

    Wei, Jinyu; Bai, Dongdong; Yang, Liying

    2015-01-01

    The effect of a new transition metal oxide, rhenium oxide (ReO3), on the performance of polymer solar cells based on regioregular poly(3-hexylthiophene) (P3HT) and methanofullerene [6,6]-phenyl C61-butyric acid methyl ester (PCBM) blend as buffer layer was investigated. The effect of the thickness of ReO3 layer on electrical characteristics of the polymer solar cells was studied. It is found that insertion of ReO3 interfacial layer results in the decreased performance for P3HT: PCBM based solar cells. In order to further explore the mechanism of the decreasing of the open-circuit voltage (Voc), the X-ray photoelectron spectroscopy (XPS) is used to investigate the ReO3 oxidation states. Kelvin Probe method showed that the work function of the ReO3 is estimated to be 5.13eV after thermal evaporation. The results indicated the fact that a portion of ReO3 decomposed during thermal evaporation process, resulting in the formation of a buffer layer with a lower work function. As a consequence, a higher energy barrier was generated between the ITO and the active layer.

  1. Influence of liposome forms of the rhenium compounds and cis-platin on thiol-disulfide coefficient in the rats’ blood

    Directory of Open Access Journals (Sweden)

    I. V. Klenina

    2007-12-01

    Full Text Available Thiol-disulfide coefficient (TDC and its different modifications in model in vivo were studied. Introduction of the liposome forms of cluster rhenium compounds with organic ligands (CROL leads to both TDC increasing and to the constancy of the TDC. Thus, CROLs aren’t toxic agents and some compounds could mobilize organisms’ thiol defence system. Liposome form of cis-platin leads to the TDC decreasing. Important CROL capacities for its future medical treatment practice were shown.

  2. Lump Kinetic Analysis of Syngas Composition Effect on Fischer-Tropsch Synthesis over Cobalt and Cobalt-Rhenium Alumina Supported Catalyst

    Directory of Open Access Journals (Sweden)

    Dewi Tristantini

    2016-03-01

    Received: 10th November 2015; Revised: 10th February 2016; Accepted: 16th February 2016 How to Cite: Tristantini, D., Suwignjo, R.K. (2016. Lump Kinetic Analysis of Syngas Composition Effect on Fischer-Tropsch Synthesis over Cobalt and Cobalt-Rhenium Alumina Supported Catalyst. Bulletin of Chemical Reaction Engineering & Catalysis, 11 (1: 84-92. (doi:10.9767/bcrec.11.1.424.84-92 Permalink/DOI: http://dx.doi.org/10.9767/bcrec.11.1.424.84-92

  3. 188Rhenium-HEDP in the treatment of pain in bone metastases

    International Nuclear Information System (INIS)

    Gaudiano, J.; Martinez, G.; Hermida, J.C.; Savio, E.; Verdera, S.; Robles, A.; Muniz, S.; Leon, A.; Knapp, F.F.

    2001-01-01

    Systemic use of radiopharmaceuticals is a recognised alternative method for the treatment of pain in patients with multiple bone metastases. A new option, 188 Re-HEDP is proposed, using generator-obtained 188 Rhenium (β energy = 2.1 MeV, γ energy = 155 keV, half-life = 16.9 hours). After establishing parameters of biodistribution, dosimetry and image acquisition in mice, rats and rabbits, Phase I and II studies were conducted on 12 patients with multiple metastases from carcinomas, with pain surpassing other analgesic options. More than 50% pain relief was found in 91% of the patients, with total relief during a variable period in 41% of them allowing opiate and other analgesic drugs to be decreased or withdrawn, and showing a lower bone marrow contribution to total absorbed dose than that reported for other similar radiopharmaceuticals. Further study of this option is recommended in order to determine higher dose protocols without toxic bone marrow reaction possibilities. (author)

  4. 188Rhenium-HEDP in the Treatment of Pain in Bone Metastases

    International Nuclear Information System (INIS)

    Gaudiano, J.; Savio, E.; Robles, A.; Muniz, S.; Leon, A.; Verdera, S.; Martinez, G.; Hermida, J.C.; Knapp, F.F. Jr.

    1999-01-01

    Systemic use of radiopharmaceuticals is a recognized alternative method for the treatment of pain in patients with multiple bone metastasis. A new option, 188 Re-HEDP is proposed, using generator-obtained 188 Rhenium (β energy = 2.1 MeV, γ energy = 155 keV, half-life = 16.9 hours). After establishing parameters of biodistribution, dosimetry and image acquisition in mice, rats and rabbits, Phase I and II studies were conducted on 12 patients with multiple metastasis from carcinomas, with pain surpassing other analgesic options. More than 50% pain relief was found in 91% of the patients, with total relief during a variable period in 41% of them allowing opiate and other analgesic drugs to be decreased or withdrawn, and showing a lower bone marrow contribution to total absorbed dose than that reported for other similar radiopharmaceuticals. Further study of this option is recommended in order to determine higher dose protocols without toxic bone marrow reaction possibilities

  5. Studies on the preparation and isomeric composition of [sup 186]Re- and [sup 188]Re-pentavalent rhenium dimercaptosuccinic acid complex

    Energy Technology Data Exchange (ETDEWEB)

    Singh, J. (Canterbury Univ. (United Kingdom). Biological Lab.); Reghebi, K.; Lazarus, C.R.; Clarke, S.E.M. (Guy' s Hospital, London (United Kingdom)); Callahan, A.P.; Knapp, F.F. Jr. (Oak Ridge National Lab., TN (United States)); Blower, P.J. (Kent and Canterbury Hospital (United Kingdom))

    1993-03-01

    The preparative conditions for [sup 186]Re(V)DMSA and [sup 188]Re(V)DMSA (DMSA = meso-dimercaptosuccinic acid), [beta]-emitting radiopharmaceuticals that have been shown to localize in medullary thyroid carcinoma, require modification depending on the amount of carrier rhenium and the chemical form and medium in which the rhenium is supplied. Preparative conditions are described for use with carrier-free [sup 188]ReO[sub 4][sup -] in saline, and for use with [sup 186]ReO[sub 4][sup -] in saline, sodium hydroxide or nitric acid. Preparation of [sup 186]Re(V)DMSA (carrier present up to 2 mg per 2.5 ml reaction volume) requires a DMSA:SnCl[sub 2]:Re ratio of 10:5:1 at 100[sup o]C for 30 min. Addition of excess nitric acid or hydrochloric acid up to a concentration of 155 mM does not reduce the yield from 100%. A commercial DMSA kit vial (e.g. Amerscan DMSA) can be used for preparation of [sup 188]Re(V)DMSA (carrier free) provided the required is in a volume of less than 1 ml per vial. A convenient method of concentrating the [sup 188]Re generator eluate to the required volume is described. (Author).

  6. Synthesis, structural characterization and photoluminescence properties of rhenium(I) complexes based on bipyridine derivatives with carbazole moieties.

    Science.gov (United States)

    Li, Hong-Yan; Wu, Jing; Zhou, Xin-Hui; Kang, Ling-Chen; Li, Dong-Ping; Sui, Yan; Zhou, Yong-Hui; Zheng, You-Xuan; Zuo, Jing-Lin; You, Xiao-Zeng

    2009-12-21

    Three N,N-bidentate ligands, 5,5'-dibromo-2,2-bipyridine (L1) and two carbazole containing ligands of 5-bromo-5'-carbazolyl-2,2-bipyridine (L2), 5,5'-dicarbazolyl-2,2'-bipyridine (L3), and their corresponding rhenium Re(CO)3Cl(L) complexes (ReL1-ReL3) have been successfully synthesized and characterized by elemental analysis, 1H NMR and IR spectra. Their photophysical properties and thermal analysis, along with the X-ray crystal structure analysis of L3 and complexes ReL1 and ReL3 are also described. In CH2Cl2 solution at room temperature, all complexes display intense absorption bands at ca. 220-350 nm, which can be assigned to spin-allowed intraligand (pi-->pi*) transitions, and the low energy broad bands in the 360-480 nm region are attributed to the metal to ligand charge-transfer d(Re)-->pi* (diimine) (MLCT). The introduction of carbazole moieties improves the MLCT absorption and molar extinction coefficient of these complexes. Upon excitation at the peak maxima, all complexes show strong emissions around 620 nm, which are assigned to d(Re)-->pi* (diimine) MLCT phosphorescence. The photoluminescence lifetime decay of Re(I) complexes were measured and the quantum efficiencies of the rhenium(I) complexes were calculated by using air-equilibrated [Ru(bpy)3]2+ x 2 Cl- aqueous solution as standard (phi(std) = 0.028). The complexes with appended carbazole moieties exhibit enhanced luminescence performances relative to ReL1.

  7. Determination of rhenium traces in river water by Q-ICP-MS and HR-ICP-MS

    International Nuclear Information System (INIS)

    Uchida, S.; Tagami, K.; Saito, M.

    2003-01-01

    A simple separation method was applied to determine rhenium in river water using Q-ICP-MS and HR-ICP-MS. Re was concentrated from 420-925 ml river water using a TEVA resin minicolumn. Such extraction using a resin could separate Re from most sample matrices and trace elements. Almost 100% recovery was found throughout the method as determined with radioactive multitracers. The HR-ICP-MS was also used for the direct determination because of its low detection limit for Re (0.007 pg/ml). The Re concentration in the river water samples ranged from 0.9 to 6.5 pg/ml and the three analysis results showed good agreement with each other. (author)

  8. Object kinetic Monte Carlo model for neutron and ion irradiation in tungsten: Impact of transmutation and carbon impurities

    Science.gov (United States)

    Castin, N.; Bonny, G.; Bakaev, A.; Ortiz, C. J.; Sand, A. E.; Terentyev, D.

    2018-03-01

    We upgrade our object kinetic Monte Carlo (OKMC) model, aimed at describing the microstructural evolution in tungsten (W) under neutron and ion irradiation. Two main improvements are proposed based on recently published atomistic data: (a) interstitial carbon impurities, and their interaction with radiation-induced defects (point defect clusters and loops), are more accurately parameterized thanks to ab initio findings; (b) W transmutation to rhenium (Re) upon neutron irradiation, impacting the diffusivity of radiation defects, is included, also relying on recent atomistic data. These essential amendments highly improve the portability of our OKMC model, providing a description for the formation of SIA-type loops under different irradiation conditions. The model is applied to simulate neutron and ion irradiation in pure W samples, in a wide range of fluxes and temperatures. We demonstrate that it performs a realistic prediction of the population of TEM-visible voids and loops, as compared to experimental evidence. The impact of the transmutation of W to Re, and of carbon trapping, is assessed.

  9. Determination of rhenium in biological and environmental samples by radiochemical neutron activation analysis

    International Nuclear Information System (INIS)

    Kucera, J.; Mizera, J.; Randa, Z.; Byrne, A.R.; Lucanikova, M.

    2006-01-01

    Radiochemical neutron activation procedures using liquid-liquid extraction with tetraphenylarsonium chloride in chloroform from 1 M HCl and solid extraction with ALIQUAT 336 incorporated in a polyacrylonitrile binding matrix from 0.1 M HCl were developed for accurate determination of rhenium in biological and environmental samples at the sub-ng.g -1 level. Concentrations of Re in the range of 0.1 to 2.4 ng.g -1 were determined in several botanical reference materials (RM), while in a RM of road dust a value of approx. 10 ng.g -1 was found. Significantly elevated values of Re, up to 90 ng.g -1 , were found in seaweed (brown algae). Results for Re in the brown algae Fucus vesiculosus in which elevated 99 Tc values had previously been determined suggest possible competition between Re and Tc in the accumulation process. (author)

  10. {sup 188}Rhenium-HEDP in the Treatment of Pain in Bone Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Gaudiano, J.; Savio, E.; Robles, A.; Muniz, S.; Leon, A.; Verdera, S.; Martinez, G.; Hermida, J.C.; Knapp, F.F., Jr.

    1999-01-18

    Systemic use of radiopharmaceuticals is a recognized alternative method for the treatment of pain in patients with multiple bone metastasis. A new option, {sup 188}Re-HEDP is proposed, using generator-obtained {sup 188}Rhenium ({beta} energy = 2.1 MeV, {gamma} energy = 155 keV, half-life = 16.9 hours). After establishing parameters of biodistribution, dosimetry and image acquisition in mice, rats and rabbits, Phase I and II studies were conducted on 12 patients with multiple metastasis from carcinomas, with pain surpassing other analgesic options. More than 50% pain relief was found in 91% of the patients, with total relief during a variable period in 41% of them allowing opiate and other analgesic drugs to be decreased or withdrawn, and showing a lower bone marrow contribution to total absorbed dose than that reported for other similar radiopharmaceuticals. Further study of this option is recommended in order to determine higher dose protocols without toxic bone marrow reaction possibilities.

  11. Identification of rhenium donors and sulfur vacancy acceptors in layered MoS{sub 2} bulk samples

    Energy Technology Data Exchange (ETDEWEB)

    Brandão, F. D., E-mail: fdbrand@fisica.ufmg.br; Ribeiro, G. M.; Vaz, P. H.; González, J. C.; Krambrock, K. [Departamento de Física, Universidade Federal de Minas Gerais, CP 702, 30.123-970 Belo Horizonte, MG (Brazil)

    2016-06-21

    MoS{sub 2} monolayers, a two-dimensional (2D) direct semiconductor material with an energy gap of 1.9 eV, offer many opportunities to be explored in different electronic devices. Defects often play dominant roles in the electronic and optical properties of semiconductor devices. However, little experimental information about intrinsic and extrinsic defects or impurities is available for this 2D system, and even for macroscopic 3D samples for which MoS{sub 2} shows an indirect bandgap of 1.3 eV. In this work, we evaluate the nature of impurities with unpaired spins using electron paramagnetic resonance (EPR) in different geological macroscopic samples. Regarding the fact that monolayers are mostly obtained from natural crystals, we expect that the majority of impurities found in macroscopic samples are also randomly present in MoS{sub 2} monolayers. By EPR at low temperatures, rhenium donors and sulfur vacancy acceptors are identified as the main impurities in bulk MoS{sub 2} with a corresponding donor concentration of about 10{sup 8–12} defects/cm{sup 2} for MoS{sub 2} monolayer. Electrical transport experiments as a function of temperature are in good agreement with the EPR results, revealing a shallow donor state with an ionization energy of 89 meV and a concentration of 7 × 10{sup 15 }cm{sup −3}, which we attribute to rhenium, as well as a second deeper donor state with ionization energy of 241 meV with high concentration of 2 × 10{sup 19 }cm{sup −3} and net acceptor concentration of 5 × 10{sup 18 }cm{sup −3} related to sulfur vacancies.

  12. Coupling an electrospray source and a solids probe/chemical ionization source to a selected ion flow tube apparatus

    International Nuclear Information System (INIS)

    Melko, Joshua J.; Ard, Shaun G.; Shuman, Nicholas S.; Viggiano, Albert A.; Pedder, Randall E.; Taormina, Christopher R.

    2015-01-01

    A new ion source region has been constructed and attached to a variable temperature selected ion flow tube. The source features the capabilities of electron impact, chemical ionization, a solids probe, and electrospray ionization. The performance of the instrument is demonstrated through a series of reactions from ions created in each of the new source regions. The chemical ionization source is able to create H 3 O + , but not as efficiently as similar sources with larger apertures. The ability of this source to support a solids probe, however, greatly expands our capabilities. A variety of rhenium cations and dications are created from the solids probe in sufficient abundance to study in the flow tube. The reaction of Re + with O 2 proceeds with a rate constant that agrees with the literature measurements, while the reaction of Re 2 2+ is found to charge transfer with O 2 at about 60% of the collision rate; we have also performed calculations that support the charge transfer pathway. The electrospray source is used to create Ba + , which is reacted with N 2 O to create BaO + , and we find a rate constant that agrees with the literature

  13. Hydrodeoxygenation of vicinal OH groups over heterogeneous rhenium catalyst promoted by palladium and ceria support.

    Science.gov (United States)

    Ota, Nobuhiko; Tamura, Masazumi; Nakagawa, Yoshinao; Okumura, Kazu; Tomishige, Keiichi

    2015-02-02

    Heterogeneous ReOx-Pd/CeO2 catalyst showed excellent performance for simultaneous hydrodeoxygenation of vicinal OH groups. High yield (>99%), turnover frequency (300 h(-1)), and turnover number (10,000) are achieved in the reaction of 1,4-anhydroerythritol to tetrahydrofuran. This catalyst can be applied to sugar alcohols, and mono-alcohols and diols are obtained in high yields (≥85%) from substrates with even and odd numbers of OH groups, respectively. The high catalytic performance of ReOx-Pd/CeO2 can be assigned to rhenium species with +4 or +5 valence state, and the formation of this species is promoted by H2/Pd and the ceria support. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Photodetectors: Broad Detection Range Rhenium Diselenide Photodetector Enhanced by (3-Aminopropyl)Triethoxysilane and Triphenylphosphine Treatment (Adv. Mater. 31/2016).

    Science.gov (United States)

    Jo, Seo-Hyeon; Park, Hyung-Youl; Kang, Dong-Ho; Shim, Jaewoo; Jeon, Jaeho; Choi, Seunghyuk; Kim, Minwoo; Park, Yongkook; Lee, Jaehyeong; Song, Young Jae; Lee, Sungjoo; Park, Jin-Hong

    2016-08-01

    The effects of triphenylphosphine (PPh3 ) and (3-amino-propyl)triethoxysilane (APTES) on a rhenium diselenide (ReSe2 ) photodetector are systematically studied by J.-H. Park and co-workers on page 6711 in comparison with a conventional MoS2 device. A very high performance ReSe2 photodetector is demonstrated, which has a broad photodetection range, high photoresponsivity (1.18 × 10(6) A W(-1) ), and fast photoswitching speed (rising/decaying time: 58/263 ms). © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Effect of heat-treatment on microstructure and high-temperature deformation behavior of a low rhenium-containing single crystal nickel-based superalloy

    International Nuclear Information System (INIS)

    Sun, Nairong; Zhang, Lanting; Li, Zhigang; Shan, Aidang

    2014-01-01

    A low rhenium-containing [001] oriented single crystal nickel-based superalloy with different γ′ morphologies induced by various aging treatments was compressed from room temperature to 1000 °C. All the single crystal samples with different γ′ morphologies exhibit anomalous yield behavior. The sample first aged at 1180 °C has the widest anomalous temperature domain and highest yield strengths. The sample first aged at 1000 °C has the highest anomalous peak stress temperature

  16. A Fluorine-18 Radiolabeling Method Enabled by Rhenium(I) Complexation Circumvents the Requirement of Anhydrous Conditions.

    Science.gov (United States)

    Klenner, Mitchell A; Pascali, Giancarlo; Zhang, Bo; Sia, Tiffany R; Spare, Lawson K; Krause-Heuer, Anwen M; Aldrich-Wright, Janice R; Greguric, Ivan; Guastella, Adam J; Massi, Massimiliano; Fraser, Benjamin H

    2017-05-11

    Azeotropic distillation is typically required to achieve fluorine-18 radiolabeling during the production of positron emission tomography (PET) imaging agents. However, this time-consuming process also limits fluorine-18 incorporation, due to radioactive decay of the isotope and its adsorption to the drying vessel. In addressing these limitations, the fluorine-18 radiolabeling of one model rhenium(I) complex is reported here, which is significantly improved under conditions that do not require azeotropic drying. This work could open a route towards the investigation of a simplified metal-mediated late-stage radiofluorination method, which would expand upon the accessibility of new PET and PET-optical probes. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. A randomised, phase II study of repeated rhenium-188-HEDP combined with docetaxel and prednisone versus docetaxel and prednisone alone in castration-resistant prostate cancer (CRPC) metastatic to bone; the Taxium II trial

    Energy Technology Data Exchange (ETDEWEB)

    Dodewaard-de Jong, Joyce M. van [VU University Medical Centre, Department of Medical Oncology, Amsterdam (Netherlands); Meander Medical Centre, Department of Medical Oncology, Amersfoort (Netherlands); Klerk, John M.H. de [Meander Medical Centre, Department of Nuclear Medicine, Amersfoort (Netherlands); Bloemendal, Haiko J. [Meander Medical Centre, Department of Medical Oncology, Amersfoort (Netherlands); University Medical Centre Utrecht, Department of Medical Oncology, Utrecht (Netherlands); Oprea-Lager, Daniela E.; Hoekstra, Otto S. [VU University Medical Centre, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Berg, H.P. van den [Tergooi Medical Hospital, Department of Medical Oncology, Hilversum (Netherlands); Los, Maartje [St Antonius Hospital Utrecht, Department of Medical Oncology, Utrecht (Netherlands); Beeker, Aart [Spaarne Gasthuis, Department of Medical Oncology, Hoofddorp (Netherlands); Jonker, Marianne A. [VU University Medical Centre, Department of Epidemiology and Biostatistics, Amsterdam (Netherlands); O' Sullivan, Joe M. [Queen' s University Belfast, Centre for Cancer Research and Cell Biology, Belfast, Northern Ireland (United Kingdom); Verheul, Henk M.W.; Eertwegh, Alfons J.M. van den [VU University Medical Centre, Department of Medical Oncology, Amsterdam (Netherlands)

    2017-08-15

    Rhenium-188-HEDP is a beta-emitting radiopharmaceutical used for palliation of metastatic bone pain. We investigated whether the addition of rhenium-188-HEDP to docetaxel/prednisone improved efficacy of chemotherapy in patients with CRPC. Patients with progressive CRPC and osteoblastic bone metastases were randomised for first-line docetaxel 75 mg/m{sup 2} 3-weekly plus prednisone with or without 2 injections of rhenium-188-HEDP after the third (40 MBq/kg) and after the sixth (20 MBq/kg) cycle of docetaxel. Primary endpoint was progression-free survival (PFS), defined as either PSA, radiographic or clinical progression. Patients were stratified by extent of bone metastases and hospital. Forty-two patients were randomised for standard treatment and 46 patients for combination therapy. Median number of cycles of docetaxel was 9 in the control group and 8 in the experimental group. Median follow-up was 18.4 months. Two patients from the experimental group did not start treatment after randomisation. In the intention to treat analysis no differences in PFS, survival and PSA became apparent between the two groups. In an exploratory per-protocol analysis median overall survival was significantly longer in the experimental group (33.8 months (95%CI 31.75-35.85)) than in the control group (21.0 months (95%CI 13.61-28.39); p 0.012). Also median PFS in patients with a baseline phosphatase >220U/L was significantly better with combination treatment (9.0 months (95%CI 3.92-14.08) versus 6.2 months (95%CI 3.08-9.32); log rank p 0.005). As expected, thrombocytopenia (grade I/II) was reported more frequently in the experimental group (25% versus 0%). Combined treatment with rhenium-188-HEDP and docetaxel did not prolong PFS in patients with CRPC. The observed survival benefit in the per-protocol analysis warrants further studies in the combined treatment of chemotherapy and radiopharmaceuticals. (orig.)

  18. Active and passive vectorization of technetium99m and 188rhenium radiopharmaceuticals for medical imaging and radiotherapy

    International Nuclear Information System (INIS)

    Lepareur, N.

    2003-11-01

    Research for new molecules for nuclear medicine is a field in constant development. Over the past few years, development of new radiopharmaceuticals for radiotherapy has renewed interest for rhenium chemistry. Indeed, its two isotopes 186 Re and 188 Re, owing to their ideal properties and their similitude with 99m Tc, which is widely used as a radiotracer for diagnostic imaging, seem very promising for the preparation of radiopharmaceuticals. In the first part of this manuscript, the synthesis of rhenium and technetium-99 complexes, [M(RPhCS3)2(RPhCS2)] (M = Re, Tc), is described. The preparation of technetium 99m based radiopharmaceuticals, analogues to the pondered complexes, is also described. The stability/reactivity of these complexes has been studied by exchange reactions with potential ligands, specially dithiocarbamates, and also by UV-visible absorption spectroscopy and thermogravimetry. The reactivity of the complexes towards dithiocarbamates leads to the possibility to bind biomolecules to the metallic core, via the dithiocarbamate moiety. This method represents a potential alternative to current ones using the so-called bifunctional approach. In the second part of this manuscript, a new kit formulation for the 188 Re labeling of lipiodol is described, using a complex analogous to those described in the previous part. The labeled oil is a potential cure for hepatocellular carcinoma. The in vitro and in vivo stability of this 188 Re-SSS lipiodol and of its analogue 99m Tc-SSS lipiodol has been studied, and also their in vivo behavior in healthy pigs. This study has shown the quasi-exclusive hepatic fixation of the radiopharmaceutical, and has proven its good stability. Its selectivity for tumors remains to be shown before trying it on humans. (author)

  19. Rhenium complexes of chromophore-appended dipicolylamine ligands: syntheses, spectroscopic properties, DNA binding and X-ray crystal structure

    International Nuclear Information System (INIS)

    Mullice, L.A.; Buurma, N.J.; Pope, S.J.A.; Laye, R.H.; Harding, L.P.

    2008-01-01

    The syntheses of two chromophore-appended dipicolylamine-derived ligands and their reactivity with penta-carbonyl-chloro-rhenium have been studied. The resultant complexes each possess the fac-Re(CO) 3 core. The ligands L 1 1-[bis(pyridine-2-yl-methyl)amino]methyl-pyrene and L 2 2-[bis(pyridine-2-yl-methyl)amino]methyl-quinoxaline were isolated via a one-pot reductive amination in moderate yield. The corresponding rhenium complexes were isolated in good yields and characterised by 1 H NMR, MS, IR and UV-Vis studies. X-Ray crystallographic data were obtained for fac-{Re(CO) 3 (L 1 )}(BF 4 ), C 34 H 26 BF 4 N 4 O 3 Re: monoclinic, P2(1)/c, a 18.327(2) Angstroms, α = 90.00 degrees, b 14.1537(14) Angstroms, β96.263(6) degrees, c = 23.511(3) Angstroms, γ 90.00 Angstroms, 6062.4(11) (Angstroms) 3 , Z=8. The luminescence properties of the ligands and complexes were also investigated, with the emission attributed to the appended chromophore in each case. Isothermal titration calorimetry suggests that fac-{Re(CO) 3 (L 1 )}(BF 4 ) self-aggregates cooperatively in aqueous solution, probably forming micelle-like aggregates with a cmc of 0.18 mM. Investigations into the DNA-binding properties of fac-{Re(CO) 3 (L 1 )}(BF 4 ) were undertaken and revealed that fac-{Re(CO) 3 (L 1 )}(BF 4 ) binding to fish sperm DNA (binding constant 1.5 ± 0.2 * 10 5 M -1 , binding site size 3.2 ± 0.3 base pairs) is accompanied by changes in the UV-Vis spectrum as typically observed for pyrene-based intercalators while the calorimetrically determined binding enthalpy (-14 ± 2 kcal mol -1 ) also agrees favourably with values as typically found for intercalators. (authors)

  20. Phosphorene/rhenium disulfide heterojunction-based negative differential resistance device for multi-valued logic

    Science.gov (United States)

    Shim, Jaewoo; Oh, Seyong; Kang, Dong-Ho; Jo, Seo-Hyeon; Ali, Muhammad Hasnain; Choi, Woo-Young; Heo, Keun; Jeon, Jaeho; Lee, Sungjoo; Kim, Minwoo; Song, Young Jae; Park, Jin-Hong

    2016-01-01

    Recently, negative differential resistance devices have attracted considerable attention due to their folded current–voltage characteristic, which presents multiple threshold voltage values. Because of this remarkable property, studies associated with the negative differential resistance devices have been explored for realizing multi-valued logic applications. Here we demonstrate a negative differential resistance device based on a phosphorene/rhenium disulfide (BP/ReS2) heterojunction that is formed by type-III broken-gap band alignment, showing high peak-to-valley current ratio values of 4.2 and 6.9 at room temperature and 180 K, respectively. Also, the carrier transport mechanism of the BP/ReS2 negative differential resistance device is investigated in detail by analysing the tunnelling and diffusion currents at various temperatures with the proposed analytic negative differential resistance device model. Finally, we demonstrate a ternary inverter as a multi-valued logic application. This study of a two-dimensional material heterojunction is a step forward toward future multi-valued logic device research. PMID:27819264

  1. Phosphorene/rhenium disulfide heterojunction-based negative differential resistance device for multi-valued logic

    Science.gov (United States)

    Shim, Jaewoo; Oh, Seyong; Kang, Dong-Ho; Jo, Seo-Hyeon; Ali, Muhammad Hasnain; Choi, Woo-Young; Heo, Keun; Jeon, Jaeho; Lee, Sungjoo; Kim, Minwoo; Song, Young Jae; Park, Jin-Hong

    2016-11-01

    Recently, negative differential resistance devices have attracted considerable attention due to their folded current-voltage characteristic, which presents multiple threshold voltage values. Because of this remarkable property, studies associated with the negative differential resistance devices have been explored for realizing multi-valued logic applications. Here we demonstrate a negative differential resistance device based on a phosphorene/rhenium disulfide (BP/ReS2) heterojunction that is formed by type-III broken-gap band alignment, showing high peak-to-valley current ratio values of 4.2 and 6.9 at room temperature and 180 K, respectively. Also, the carrier transport mechanism of the BP/ReS2 negative differential resistance device is investigated in detail by analysing the tunnelling and diffusion currents at various temperatures with the proposed analytic negative differential resistance device model. Finally, we demonstrate a ternary inverter as a multi-valued logic application. This study of a two-dimensional material heterojunction is a step forward toward future multi-valued logic device research.

  2. Thermal transformations of oxohalide complexes of rhenium(5) and molybdenum(5) with diazo-18-crown-6 in solid phase

    International Nuclear Information System (INIS)

    Ashurova, N.Kh.; Yakubov, K.G.

    1992-01-01

    Methods for synthesis and separation in solid state of the rhenium(5) and molybdenum(5) onium complexes with diaza-18-crown-6(L), the content of which according to the data of elementary analysis, IRS in the close and remote areas, thermogravimetry, conductometry and potentiometry corresponds to the (H 2 L)[EOX 5 ], where E = Re, Mo; X = Cl - , Br - . Thermotransformation of onium compounds is studied by methods of thermal methods (TG-DTG-DTA combined study). Their avility to be affected by solid-phase dehydrohalogenization, e.i. anderson regrouping. The thermolysis products, corresponding to the general formula (EOLX 3 ), are separated and studied

  3. Probing surface sites of TiO2: reactions with [HRe(CO)5] and [CH3Re(CO)5].

    Science.gov (United States)

    Lobo-Lapidus, Rodrigo J; Gates, Bruce C

    2010-10-04

    Two carbonyl complexes of rhenium, [HRe(CO)(5)] and [CH(3)Re(CO)(5)], were used to probe surface sites of TiO(2) (anatase). These complexes were adsorbed from the gas phase onto anatase powder that had been treated in flowing O(2) or under vacuum to vary the density of surface OH sites. Infrared (IR) spectra demonstrate the variation in the number of sites, including Ti(+3)-OH and Ti(+4)-OH. IR and extended X-ray absorption fine structure (EXAFS) spectra show that chemisorption of the rhenium complexes led to their decarbonylation, with formation of surface-bound rhenium tricarbonyls, when [HRe(CO)(5)] was adsorbed, or rhenium tetracarbonyls, when [CH(3)Re(CO)(5)] was adsorbed. These reactions were accompanied by the formation of water and surface carbonates and removal of terminal hydroxyl groups associated with Ti(+3) and Ti(+4) ions on the anatase. Data characterizing the samples after adsorption of [HRe(CO)(5)] or [CH(3)Re(CO)(5)] determined a ranking of the reactivity of the surface OH sites, with the Ti(+3)-OH groups being the more reactive towards the rhenium complexes but the less likely to be dehydroxylated. The two rhenium pentacarbonyl probes provided complementary information, suggesting that the carbonate species originate from carbonyl ligands initially bonded to the rhenium and from hydroxyl groups of the titania surface, with the reaction leading to the formation of water and bridging hydroxyl groups on the titania. The results illustrate the value of using a family of organometallic complexes as probes of oxide surface sites.

  4. Active and passive vectorization of technetium{sup 99m} and {sup 188}rhenium radiopharmaceuticals for medical imaging and radiotherapy; Vectorisations active et passive de radiopharmaceutiques du technetium-99m et du rhenium-188 pour l'imagerie medicale et la therapie

    Energy Technology Data Exchange (ETDEWEB)

    Lepareur, N

    2003-11-15

    Research for new molecules for nuclear medicine is a field in constant development. Over the past few years, development of new radiopharmaceuticals for radiotherapy has renewed interest for rhenium chemistry. Indeed, its two isotopes {sup 186}Re and {sup 188}Re, owing to their ideal properties and their similitude with {sup 99m}Tc, which is widely used as a radiotracer for diagnostic imaging, seem very promising for the preparation of radiopharmaceuticals. In the first part of this manuscript, the synthesis of rhenium and technetium-99 complexes, [M(RPhCS3)2(RPhCS2)] (M = Re, Tc), is described. The preparation of technetium{sup 99m} based radiopharmaceuticals, analogues to the pondered complexes, is also described. The stability/reactivity of these complexes has been studied by exchange reactions with potential ligands, specially dithiocarbamates, and also by UV-visible absorption spectroscopy and thermogravimetry. The reactivity of the complexes towards dithiocarbamates leads to the possibility to bind biomolecules to the metallic core, via the dithiocarbamate moiety. This method represents a potential alternative to current ones using the so-called bifunctional approach. In the second part of this manuscript, a new kit formulation for the {sup 188}Re labeling of lipiodol is described, using a complex analogous to those described in the previous part. The labeled oil is a potential cure for hepatocellular carcinoma. The in vitro and in vivo stability of this {sup 188}Re-SSS lipiodol and of its analogue {sup 99m}Tc-SSS lipiodol has been studied, and also their in vivo behavior in healthy pigs. This study has shown the quasi-exclusive hepatic fixation of the radiopharmaceutical, and has proven its good stability. Its selectivity for tumors remains to be shown before trying it on humans. (author)

  5. Active and passive vectorization of technetium{sup 99m} and {sup 188}rhenium radiopharmaceuticals for medical imaging and radiotherapy; Vectorisations active et passive de radiopharmaceutiques du technetium-99m et du rhenium-188 pour l'imagerie medicale et la therapie

    Energy Technology Data Exchange (ETDEWEB)

    Lepareur, N

    2003-11-15

    Research for new molecules for nuclear medicine is a field in constant development. Over the past few years, development of new radiopharmaceuticals for radiotherapy has renewed interest for rhenium chemistry. Indeed, its two isotopes {sup 186}Re and {sup 188}Re, owing to their ideal properties and their similitude with {sup 99m}Tc, which is widely used as a radiotracer for diagnostic imaging, seem very promising for the preparation of radiopharmaceuticals. In the first part of this manuscript, the synthesis of rhenium and technetium-99 complexes, [M(RPhCS3)2(RPhCS2)] (M = Re, Tc), is described. The preparation of technetium{sup 99m} based radiopharmaceuticals, analogues to the pondered complexes, is also described. The stability/reactivity of these complexes has been studied by exchange reactions with potential ligands, specially dithiocarbamates, and also by UV-visible absorption spectroscopy and thermogravimetry. The reactivity of the complexes towards dithiocarbamates leads to the possibility to bind biomolecules to the metallic core, via the dithiocarbamate moiety. This method represents a potential alternative to current ones using the so-called bifunctional approach. In the second part of this manuscript, a new kit formulation for the {sup 188}Re labeling of lipiodol is described, using a complex analogous to those described in the previous part. The labeled oil is a potential cure for hepatocellular carcinoma. The in vitro and in vivo stability of this {sup 188}Re-SSS lipiodol and of its analogue {sup 99m}Tc-SSS lipiodol has been studied, and also their in vivo behavior in healthy pigs. This study has shown the quasi-exclusive hepatic fixation of the radiopharmaceutical, and has proven its good stability. Its selectivity for tumors remains to be shown before trying it on humans. (author)

  6. Design criteria for rhenium-reduced nickel-based single-crystal alloys. Identification and computer-assisted conversion; Designkriterien fuer rheniumreduzierte Nickelbasis-Einkristalllegierungen. Identifikation und rechnergestuetzte Umsetzung

    Energy Technology Data Exchange (ETDEWEB)

    Goehler, Thomas

    2016-06-17

    In the present work, design criteria and property models for the creep strength optimization of rhenium-free nickel based single crystal Superalloys are investigated. The study focuses on a typical load condition of 1050 C and 150 MPa, which is representative for flight engine applications. Thereby the key aspect is to link chemical composition, manufacturing processes, microstructure formation and mechanistic understanding of dislocation creep through a computational materials engineering approach. Beside the positive effect of rhenium on solid solution hardening, a second mechanism in which rhenium increases high temperature creep strength is identified. It indirectly stabilizes precipitation hardening by reducing the coarsening kinetics of γ'-rafting. Five 1st and 2nd generation technical Superalloys show a comparable microstructure evolution for up to 2 % plastic elongation, while creep times differ by a factor of five. The application of a microstructure sensitive creep model shows that these coarsening processes can activate γ-cutting and thus lead to an increasing creep rate. Based on these calculations a threshold value of φ{sub γ/γ'} > 2,5 at 150 MPa is estimated. This ratio of matrix channel to raft thickness has been proofed for multiple positions by microstructure analysis of interrupted creep tests. The mechanism described previously can be decelerated by the enrichment of the γ-matrix with slow diffusing elements. The same principle also increases the solid solution strength of the γ-matrix. Therefore, the present work delivers an additional mechanistic explanation why creep properties of single phase nickel based alloys can be transferred to two phase technical Superalloys with rafted γ'-structure. Following, the best way to substitute both rhenium fundamental properties, namely a slow diffusion coefficient and a small solubility in g', has been investigated by means of CALPHAD-modeling. Only molybdenum and especially

  7. The oxidation of ReCl_5 with oleum: synthesis and crystal structure of Re_2O_4Cl_4(SO_4)

    International Nuclear Information System (INIS)

    Betke, Ulf; Wickleder, Mathias S.

    2012-01-01

    The reaction of ReCl_5 and fuming sulfuric acid (25 % SO_3) in a sealed glass tube at 200 C led to red, needle shaped single crystals of Re_2O_4Cl_4(SO_4) (monoclinic, C2/c, a = 1501.8(2) pm, b = 1545.9(2) pm, c = 945.18(8) pm, β = 98.761(9) , Z = 8). In the crystal structure the [ReO_2] moieties are linked by [SO_4]"2"- tetrahedra to chains along the [101] direction. Each sulfate ion connects four rhenium atoms, additional two chloride ions complete the octahedral coordination sphere of each rhenium atom according to "1_∞[ReO_2_/_1Cl_2_/_1(SO_4)_2_/_4]. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  8. Laser-induced breakdown spectroscopy measurement of a small fraction of rhenium in bulk tungsten

    Science.gov (United States)

    Nishijima, D.; Ueda, Y.; Doerner, R. P.; Baldwin, M. J.; Ibano, K.

    2018-03-01

    Laser-induced breakdown spectroscopy (LIBS) of bulk rhenium (Re) and tungsten (W)-Re alloy has been performed using a Q-switched Nd:YAG laser (wavelength = 1064 nm, pulse width ∼4-6 ns, laser energy = 115 mJ). It is found that the electron temperature, Te, of laser-induced Re plasma is lower than that of W plasma, and that Te of W-Re plasma is in between Re and W plasmas. This indicates that material properties affect Te in a laser-induced plasma. For analysis of W-3.3%Re alloy, only the strongest visible Re I 488.9 nm line is found to be used because of the strong enough intensity without contamination with W lines. Using the calibration-free LIBS method, the atomic fraction of Re, cRe, is evaluated as a function of the ambient Ar gas pressure, PAr. At PAr 10 Torr due to spectral overlapping of the Re I 488.9 nm line by an Ar II 488.9 nm line.

  9. Prototype commercial electrooxidation cell for the recovery of molybdenum and rhenium from molybdenite concentrates

    International Nuclear Information System (INIS)

    Scheiner, B.J.; Pool, D.L.; Lindstrom, R.E.; McCleland, G.E.

    1979-01-01

    As part of the goal to maximize minerals and metals recovery from primary domestic resources, design factors associated with minimizing current leakage in bipolar cell configurations were studied as a means of improving the efficiency of bipolar electrooxidation cells. Initial studies that were conducted in a small bipolar cell operating at 140 to 145 volts and 15.4 A indicated how design factors could be employed to minimize current leakage around adjacent electrodes during cell operation. Based on these results, a 40-electrode, 108-kVA prototype of an industrial-sized cell was constructed and tested for extracting metal values from offgrade molybdenite concentrates. The feasibility of recovering molybdenum and rhenium from the oxidized pulp also was determined. Feed to the process sequence consisted of flotation concentrates containing 16 to 35% Mo as molybdenite and 6 to 15% Cu. Electrooxidation in the prototype cell results in 84 to 97% Mo and Re extraction with a corresponding energy consumption of 9 to 13 kWh/lb Mo extracted

  10. SPS Fabrication of Tungsten-Rhenium Alloys in Support of NTR Fuels Development

    International Nuclear Information System (INIS)

    Webb, Jonathan A.; Charit, Indrajit; Sparks, Cory; Butt, Darryl P.; Frary, Megan; Carroll, Mark

    2011-01-01

    Tungsten metal slugs were fabricated via Spark Plasma Sintering (SPS) of powdered metals at temperatures ranging from 1575 K to 1975 K and hold times of 5 minutes to 30 minutes, using powders with an average diameter of 7.8 ?m. Sintered tungsten specimens were found to have relative densities ranging from 83 % to 94 % of the theoretical density for tungsten. Consolidated specimens were also tested for their Vickers Hardness Number (VHN), which was fitted as a function of relative density; the fully consolidated VHN was extrapolated to be 381.45 kg/mm2. Concurrently, tungsten and rhenium powders with average respective diameters of 0.5 ?m and 13.3 ?m were pre-processed either by High-Energy-Ball-Milling (HEBM) or by homogeneous mixing to yield W-25at.%Re mixtures. The powder batches were sintered at temperatures of 1975 K and 2175 K for hold times ranging from 0 minutes to 60 minutes yielding relative densities ranging from 94% to 97%. The combination of HEBM and sintering showed a significant decrease in the inter-metallic phases compared to that of the homogenous mixing and sintering.

  11. Rhenium 188 labelling of peptide conjugates

    International Nuclear Information System (INIS)

    Melendez-Alafort, Laura

    2001-01-01

    Many human tumours express high levels, of somatostatin receptors. In order to make possible a radiotherapeutic treatment of this kind for tumour a series of somatostatin analogues that can tightly chelate beta emitting isotopes have been developed in recent years. The work carried out for this thesis has been aimed towards development of a new therapeutic radiopharmaceutical for treatment of somatostatin receptor positive tumours. The first chapters describe work with technetium-99m to establish the labelling and analytical conditions for a somatostatin analogue, [Tyr 3 ]-octreotide (TOC), as a precursor to undertaking labelling studies with the beta emitter rhenium-188. 6-Hydrazinopyridine-3-carboxylic acid (HYNIC) was conjugated to TOC and labelled with 99m using different coligands. Then the stability, receptor binding and biodistribution of each complex were assessed. 99m Tc-HYNIC-TOC using EDDA as coligand showed the best characteristics, and was superior for tumour imaging in humans than the commercially available 111 In-DTPA-octreotide. The conditions for labelling the HYNIC-TOC conjugate with 188 Re were then optimised using tricine as a co-ligand. A labelling yield of ∼80% was achieved. After purification however, the stability of the complex was low. The use of other coligand systems which had proved useful for 99m Tc labelling was explored, but yields were very poor. Other chelators such as diethylenetriamine pentaacetic acid (DTPA), dimercaptosuccinic acid (DMSA) and mercaptoacetyltriglycine (MAG 3 ) were studied as potential co-ligand agents to label the HYNIC-TOC conjugate with 188 Re but, again low yields of the labelled peptide complexes were achieved. A novel 188 Re-HYNIC complex was prepared in high yields using N-N-disubstituted dithiocarbamates as coligands. However to date, the specific activities achieved with this system are relatively low. The use of the [ 99m Tc(CO) 3 (H 2 O) 3 ] complex to label the HYNIC-TOC conjugate was investigated

  12. Study of technetium behaviour in radiopharmaceuticals. Characterization of sup(99m)Tc-pyrophosphate, sup(99m)Tc-dimercaptosuccinate, sup(99m)Tc-diethylenetriaminepentaacetate complexes and sup(99m)Tc-colloidal rhenium sulphide

    International Nuclear Information System (INIS)

    Saccavini, J.-C.

    1980-12-01

    The chemistry of technetium in extremely dilute solution was approached through the study of three complexing agents and a colloid. By the application of high-performance chromatographic techniques to the analysis of (Tc-pyro), (Tc-DTPA), (Tc-DMSA) complexes it was possible to isolate one or more chelates from a single complexing agent. Addition of pertechnetates to a solution of sodium pyrophosphates and stannous chloride at neutral pH leads to the formation of two complexes, both highly osteotropic. By the use of sup(117m)Sn it was shown that tin employed as reducing agent enters into the composition of one of the two complexes, either of which may be obtained preferentially by varying the (Sn)/(pyro) ratio. With technetium at acid pH (2.5) DMSA gives one or more chelates according to the concentration of the reagents present. DTPA with technetium at neutral pH gives a single complex for which a structure is proposed. The addition of calcium, indispensable for DTPA injection, leads to the appearance of a second bimetallic complex in very much smaller proportions than the first. The size distribution of some colloids was studied by ultrafiltration and permeation on gel. The preparation of colloidal rhenium sulphide and the technetium labelling conditions needed to obtain a very fine colloid were developed. The behaviour of technetium in the presence of colloidal rhenium sulphide and tin pyrophosphate was followed by sup(99m)Tc - sup(186)Re and sup(99m)Tc - sup(117m)Sn double-labelling tests. One reduced technetium fraction associates with the hydrolysed tin, the other follows the rhenium sulphide [fr

  13. Phase stability, physical properties of rhenium diboride under high pressure and the effect of metallic bonding on its hardness

    International Nuclear Information System (INIS)

    Zhong, Ming-Min; Kuang, Xiao-Yu; Wang, Zhen-Hua; Shao, Peng; Ding, Li-Ping; Huang, Xiao-Fen

    2013-01-01

    Highlights: •The transition pressure P t between the ReB 2 –ReB 2 and MoB 2 –ReB 2 phases is firstly determinate. •The single-bonded B–B feather remains in ReB 2 compounds. •A semiempirical method to evaluate the hardness of crystals with partial metallic bond is presented. •The large hardness (39.1 GPa) of ReB 2 –ReB 2 indicate that it is a superhard material. •The zigzag interconnected B–Re and B–B covalent bonds underlie the ultraincompressibilities. -- Abstract: Using first-principles calculations, the elastic constants, thermodynamic property and structural phase transition of rhenium diboride under pressure are investigated by means of the pseudopotential plane-waves method, as well as the effect of metallic bond on its hardness. Eight candidate structures of known transition-metal compounds are chosen to probe for rhenium diboride ReB 2 . The calculated lattice parameters are consistent with the experimental and theoretical values. Based on the third order Birch–Murnaghan equation of states, the transition pressure P t between the ReB 2 –ReB 2 and MoB 2 –ReB 2 phases is firstly determinate. Elastic constants, shear modulus, Young’s modulus, Poisson’s ratio and Debye temperature are derived. The single-bonded B–B feather remains in ReB 2 compounds. Furthermore, according to Mulliken overlap population analysis, a semiempirical method to evaluate the hardness of multicomponent crystals with partial metallic bond is presented. Both strong covalency and a zigzag topology of interconnected bonds underlie the ultraincompressibilities. In addition, the superior performance and large hardness (39.1 GPa) of ReB 2 –ReB 2 indicate that it is a superhard material

  14. The chemistry on a subnanometer scale of radiation-induced precipitation and segregation in fast-neutron irradiated tungsten-rhenium alloys

    International Nuclear Information System (INIS)

    Hershitz, R.; Seidman, D.N.

    1984-01-01

    The phenomena of radiation-induced precipitation and segregation have been investigated in W-10 at.% Re and W-25 at.% Re alloys, employing the atom-probe field-ion-microscope technique. The specimens had been irradiated to a fast-neutron fluence of approx.4x10 22 neutrons cm -2 (e>0.1 MeV) at 575, 625 and 675 deg C. This corresponds to 8.6 dpa and an average displacement rate, for the two year irradiation time of 1.4x10 -7 dpa s -1 . In the W-10 at.% Re alloy, coherent, semicoherent and possibly incoherent precipitates with the composition approx.WRe and a disc-shaped morphology -- one or two atomic planes thick -- were detected at a number density of approx.10 16 cm -3 , and a mean diameter of approx.57 A. In the W-25 at.% Re alloy the same precipitates with the composition approx.WRe 3 were detected at a number density of approx.10 17 cm -3 and a mean diameter of 40 A. The semicoherent WRe 3 precipitates were associated with 4 He atoms; that is, they may have been heterogeneously nucleated. None of the other precipitates were associated with either line or planar defects or with any impurity atoms. Therefore, a true homogeneous radiation-induced precipitation occurs in these alloys. In the W-25 at.% Re alloy a two dimensional WRe 3 phase has been observed at a grain boundary. The nucleation of both precipitates in the vicinity of displacement cascades might be produced by primary knock-on atoms. In both cases, the first step in the nucleation is due to the formation of tightly-bound mobile mixed dumbbells which react to form an immobile di-rhenium cluster. Point-defect mechanisms for all the other observations are also discussed

  15. 3.3.1. Synthesis, Spectroscopy and Structural Analysis of Technetium and Rhenium Nitrosyl Complexes

    Directory of Open Access Journals (Sweden)

    Terrence\tNicholson*,\tEsther\tChunb, Ashfaq\tMahmood,\tPeter\tMueller,\tAlan\tDavisona\tand\tAlun\tG.\tJones

    2015-11-01

    Full Text Available Here we report an overview of our synthetic, spectroscopic and structural studies of technetium and rhenium nitrosyl complexes. We review the results from various notes and short papers reported over the past 15 years and discuss their significance in terms of radiopharmaceutical design.A single new complex is reported, the ReI-NO complex [ReICl2(NO(py-N(Et-py], in which the tridentate ligand di-(2-picolyl(N-ethylamine, (py-N(Et-py, is coordinated in a meridional manner. This complex was synthesized from the reaction of the ReI-nitrosyl complex ReCl2(NO(NCMe3] and the neutral tri-amine ligand py-N(Et-py in methylene chloride under argon. The bright red species was isolated chromatographically and recrystallized from CH2Cl2/MeOH under diethylether.A review of literature values for nitrosyl complexes with various ligands bound to the coordination sitetrans- to the nitrosyl group shows only minor variations in the M-N-O bond angle.

  16. Application of rhenium 186 radiosynovectomy in elbow diffuse pigmented villonodular synovitis: Case report with multiple joint involvement

    International Nuclear Information System (INIS)

    Koca, Go Khan; Ozsoy, Ha Kan; Atilgan, Hasan Ikbal; Demirel, Koray; Dincel, Veysel Ercan; Korkmaz, Meliha

    2012-01-01

    After surgical therapy of diffuse pigmented villonodular synovitis (DPVNS), recurrence is seen in almost half of the patients. The effectiveness of radiosynovectomy (RSV)in preventing recurrence and complaints of DPVNS is well known. Elbow involvement in DPVNS is a very rare condition; therefore, RSV in elbow hasn't been experienced widely. The aim of this case report is to show the effectiveness of RSV with rhenium 186 (Re 186)sulfide colloid. We applied Re 186 sulfide colloid to the elbow joint of DPVNS patients six weeks after arthroscopic synovectomy. As a result, the patient did not have any complaints, and our findings are compatible with residue or recurrence on magnetic resonance imaging (MRI)in sixth and twentieth month controls after administration. We concluded that Re 186 is an effective adjuvant therapy for the prevention of recurrence and complaints

  17. Rhenium (5) and molybdenum (5) complexes with 4',4''(5'')-ditretbutyldibenzo-24-crown-8. Kompleksnye soedineniya reniya (5) i molibdena (5) s 4',4''(5'')-ditretbutildibenzo-24-kraun-8

    Energy Technology Data Exchange (ETDEWEB)

    Ashurova, N Kh; Yakubov, K G; Basitova, S M; Tashmukhamedova, A K; Sajfullina, N Zh [Tadzhikskij Gosudarstvennyj Univ., Dushanbe (USSR)

    1989-10-01

    Rhenium and molybdenum complexes in +5 oxidation degree with 4',4''(5'')-ditretbutyldibenzo-24-crown-8 (L) are synthesized with 75-95 % yield. Composition and structure of compounds produced are investigated using element analysis, conductometry, IR spectroscopy, thermogravimetry methods. Oxidation degree of complexer metal is determined. It is ascertained that the compound composition corresponds to the MOLX{sub 3} formula, where M-Re, Mo; X-Cl{sup -}, Br{sup -}.

  18. The oxidation of ReCl{sub 5} with oleum: synthesis and crystal structure of Re{sub 2}O{sub 4}Cl{sub 4}(SO{sub 4})

    Energy Technology Data Exchange (ETDEWEB)

    Betke, Ulf; Wickleder, Mathias S. [Carl von Ossietzky University of Oldenburg, Institute of Pure and Applied Chemistry (Germany)

    2012-01-15

    The reaction of ReCl{sub 5} and fuming sulfuric acid (25 % SO{sub 3}) in a sealed glass tube at 200 C led to red, needle shaped single crystals of Re{sub 2}O{sub 4}Cl{sub 4}(SO{sub 4}) (monoclinic, C2/c, a = 1501.8(2) pm, b = 1545.9(2) pm, c = 945.18(8) pm, β = 98.761(9) , Z = 8). In the crystal structure the [ReO{sub 2}] moieties are linked by [SO{sub 4}]{sup 2-} tetrahedra to chains along the [101] direction. Each sulfate ion connects four rhenium atoms, additional two chloride ions complete the octahedral coordination sphere of each rhenium atom according to {sup 1}{sub ∞}[ReO{sub 2/1}Cl{sub 2/1}(SO{sub 4}){sub 2/4}]. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  19. Thermal transformations of oxohalide complexes of rhenium(5) and molybdenum(5) with diazo-18-crown-6 in solid phase. Termicheskie prevrashcheniya oksogalogenidnykh kompleksov reniya(5) i molibdena(5) s diaza-18-kraun-6 v tverdoj faze

    Energy Technology Data Exchange (ETDEWEB)

    Ashurova, N Kh; Yakubov, K G [Tadzhikskij Gosudarstvennyj Univ., Dushanbe (Tajikistan)

    1992-11-01

    Methods for synthesis and separation in solid state of the rhenium(5) and molybdenum(5) onium complexes with diaza-18-crown-6(L), the content of which according to the data of elementary analysis, IRS in the close and remote areas, thermogravimetry, conductometry and potentiometry corresponds to the (H[sub 2]L)[EOX[sub 5

  20. Radiolabeling and biotinylation of internalizing monoclonal antibody chimeric BR96: Potential use of extracorporeal immunoadsorption with enhanced tumor radioactivity retention of Iodine, Indium and Rhenium

    International Nuclear Information System (INIS)

    Chen, JianQing.

    1997-01-01

    In this thesis, methodology of radiolabeling and simultaneous biotinylation for internalizing monoclonal antibody chimeric BR96 have been investigated by using three element groups of potential therapeutic radionuclides iodine, indium and rhenium, and their different labeling methods. The biodistribution and kinetics of biotinylated and radiolabeled chiBR96 have been studied in colon carcinoma isografted rats. The potential use of ECIA, based on the biotin-avidin concept, has been evaluated and compared with the approach of avidin 'chase' in the same animal tumor model with respect to an enhancement of tumor-to-normal tissue (T/N) activity ratio. 131 refs

  1. Radiolabeling and biotinylation of internalizing monoclonal antibody chimeric BR96: Potential use of extracorporeal immunoadsorption with enhanced tumor radioactivity retention of Iodine, Indium and Rhenium

    Energy Technology Data Exchange (ETDEWEB)

    Chen, JianQing

    1997-01-01

    In this thesis, methodology of radiolabeling and simultaneous biotinylation for internalizing monoclonal antibody chimeric BR96 have been investigated by using three element groups of potential therapeutic radionuclides iodine, indium and rhenium, and their different labeling methods. The biodistribution and kinetics of biotinylated and radiolabeled chiBR96 have been studied in colon carcinoma isografted rats. The potential use of ECIA, based on the biotin-avidin concept, has been evaluated and compared with the approach of avidin `chase` in the same animal tumor model with respect to an enhancement of tumor-to-normal tissue (T/N) activity ratio. 131 refs.

  2. Isotope ratio measurements of pg-size plutonium samples using TIMS in combination with the 'Multiple Ion Counting' and filament carburization

    Energy Technology Data Exchange (ETDEWEB)

    Jakopic, Rozle; Richter, Stephan; Kuehn, Heinz; Aregbe, Yetunde [European Commission, Directorate General Joint Research Centre Institute for Reference Materials and Measurements, IRMM Retieseweg 111, B-2440 Geel (Belgium)

    2008-07-01

    A new sample preparation procedure for isotopic measurements using the Triton TIMS (Thermal Ionization Mass Spectrometer) was developed which employed the technique of carburization of rhenium filaments. Carburized filaments were prepared in a special vacuum chamber in which the filaments were heated and exposed to benzene vapor. Ionization efficiency was improved by an order of magnitude. Additionally, a new 'multi-dynamic' measurement technique was developed for Pu isotope ratio measurements using the 'multiple ion counting' (MIC) system. This technique was further combined with the filament carburization technique and applied to the NBL-137 isotopic standard and samples of the NUSIMEP 5 inter-laboratory comparison campaign. The results clearly show an improved precision and accuracy for the 'multi-dynamic' measurement procedure, compared to measurements carried out either in peak-jumping or in static mode using the MIC system with non-carburized filaments. (authors)

  3. Trinuclear rhenium(III) halide clusters with carboxylate ligands

    Science.gov (United States)

    Dougan, Jeffrey Steven

    Four mono(carboxylato)trirhenium complexes and three bis(carboxylato)trirhenium complexes have been synthesized and characterized, principally by mass spectrometry, with supporting evidence from X-ray diffraction. These compounds represent the first trinuclear rhenium carboxylate complexes. The reactions generally proceed readily under comparatively mild conditions. Mass spectrometry has again proved its usefulness as a technique in the field of metal cluster chemistry, having provided the initial identification of the products of the reactions studied. These compounds provide a further base to which future mass spectra of metal cluster compounds can be compared. Re-examination of a reaction reported by Taha and Wilkinson has also cast considerable doubt onto the validity of a conversion widely reported in the literature that transforms (Re3Cl9) x into [Re2(O2CCH3)4Cl 2]. We believe that the literature result is a consequence of the purity of the metal precursor, and suggest that the starting material in the earlier work may have contained ReCl4 or ReCl5. The importance of mass spectrometry in the characterization of the new compounds synthesized in this project has led to a thorough study of calculated isotopic distributions. The information gathered suggests that for isotopically simple molecules, the choice of algorithm for computing an isotopic distribution is unimportant. However, it is important to compute the mass spectrum of an isotopically complex molecule using an algorithm that can, if desired, show the underlying isotopic fine structure of a peak of interest. In the last chapter of this thesis, the results of a project in chemistry education research are presented. Predicting the success of students in general chemistry has long been of interest to the chemistry education community, and several factors have been identified as contributing factors. An off-hand comment by a student inspired an examination of whether continuity with the same instructor for

  4. Sorption of technetium and its analogue rhenium on bentonite material under aerobic conditions

    International Nuclear Information System (INIS)

    Koudelkova, M.; Vinsova, H.; Konirova, R.; Ernestova, M.; Jedinakova-Krizova, V.; Tereesha, M.

    2003-01-01

    The uptake of technetium on bentonite materials has been studied from the point of view of characterization of long-term radioactive elements behavior in nuclear waste repository. Bentonite R (locality Rokle, Czech Republic) and two types of model groundwater (granitic and bentonite) were selected for the sorption experiments. The aim of our research has been to find out the conditions suitable for the technetium sorption on selected bentonite under oxidizing condition. The sorption experiments with Tc-99 on bentonite have been carried out by batch method. The influence of the addition of different materials (e.g. activated carbon, graphite, Fe 2+ ) with bentonite, the effect of solid: aqueous phase ratio and a pH value on the percentage of technetium uptake and on the K d values were tested. Perrhenate was selected as an analogue of pertechnetate in non-active experiments of capillary electrophoresis (CE) and isotachophoresis (ITP). The percentage of rhenium sorbed on bentonite material was determined from the decrease of perrhenate peak area (CE) and from the shortening of the ITP zone corresponding to perrhenate. Both electromigration methods provided comparable results. The results obtained in this study with non-active material were compared to those of technetium acquired by radiometry and polarography. The 8 days kinetics of the perrhenate and pertechnetate sorption on bentonite was described mathematically with a tendency to predict long-term behavior of studied systems. (authors)

  5. Clinical studies on the lymph flow of the esophagus by injecting sup(99m)Tc-rhenium colloid into the esophageal wall

    International Nuclear Information System (INIS)

    Baba, Masamichi; Tanabe, Gen; Nishi, Mitsumasa

    1985-01-01

    Using 29 operative cases lymph flow of the esophagus was investigated by injecting endoscopically sup(99m)Tc-Rhenium colloid. Rhenium colloid lymphoscintigraphy was made, and 30 -- 32 hours after injection RI up take (cpm/g) of resected lymph nodes was counted by scintillation counter. 1. RI up take of resected lymph nodes correspond with the lymphoscintigraphy of resected lymph nodes therefore, RI up take count was available to study the extra-mural lymph flow of the esophagus. 2. In the cases injected at upper part of the esophagus, the high counted RI up take was noted in bifurcation lymph nodes, upper mediastinal lymph nodes and bilateral supraclavicular lymph nodes. In the cases injected at middle part of the esophagus, bilateral supraclavicular lymph nodes, upper mediastinal lymph nodes and left gastric artery lymph nodes revealed the high RI up takes. In the cases injected at lower part of the esophagus, RI up take was highly noted in bifurcation lymph nodes, left gastric artery lymph nodes and celiac axis lymph nodes. In the cases injected at esophago-gastric junction, the high counted RI up take was noted in left gastric artery lymph nodes, celiac axis lymph nodes and the lymph nodes around the left renal vein. 3. In the cases injected at upper, middle parts of the esophagus, bilateral supraclavicular lymph nodes revealed the high RI up take. Some of these lymph nodes are regarded as directly connected with the extra-mural lymph vessls of the esophagus. Therefore, it was suggested that existence of ''direct lymph flow'' from which upper, middle intrathoracic esophagus directly connected to right supraclavicular lymph nodes. 4. It is important to perform bilateral modified neck dissection in case of upper, middle intrathoracic esophageal cancer and is important to dissect the lymph nodes around the left renal vein in case of esophago-gastric cancer and lower intrathoracic esophageal cancer. (J.P.N.)

  6. Synthesis and investigation of CrB{sub 4}, MnB{sub 4} and new ternary chromium and rhenium manganese borides; Synthese und Untersuchung von CrB{sub 4}, MnB{sub 4} sowie neuen ternaeren Chrom- und Rheniummanganboriden

    Energy Technology Data Exchange (ETDEWEB)

    Knappschneider, Arno

    2014-10-13

    In the present work single crystals of the tetraborides of chromium and manganese have been grown and allowed a structure refinement of the compounds. Furthermore the physical characteristics for example hardness, electronic properties and magnetism were been determined. Also the ternary tetraboride phase of chromium and manganese was synthesized and a new ternary rhenium manganese diboride could be obtained.

  7. Pharmacokinetic properties of new antitumor radiopharmaceutical on the basis of diamond nanoporous composites labeled with rhenium-188

    International Nuclear Information System (INIS)

    Petriev, V M; Tishchenko, V K; Kuril’chik, A A; Skvortsov, V G

    2017-01-01

    Today the development of address therapeutic radionuclide delivery systems directly to tumor tissue is of current interest. It can be achieved by the design of drug containers of specific sizes and shapes from carbon-based composite materials. It will be allowed to enhance the efficacy of anticancer therapy and avoid serious side effects. In this work we studied the pharmacokinetic properties of nanodiamond nanoporous composite labeled with rhenium-188 in rats with hepatocholangioma PC-1 after intratumoral injection. It was established that substantial part of injected radioactivity remained in tumor tissue. Within three hours after 188 Re-nanoporous composites injection activity in tumor constituted 79.1–91.3% of injected dose (ID). Then activity level declined to 45.9% ID at 120 hours. No more than 1.34% ID entered the bloodstream. In soft organs and tissues, except thyroid gland, the content of compound didn’t exceed 0.3% ID/g. The highest activity in thyroid gland was 6.95% ID/g. In conclusion, received results suggest 188 Re-nanoporous composites can be promising radionuclide delivery systems for cancer treatment. (paper)

  8. Syntheses and structures of technetium(V) and rhenium(V) oxo complexes of peptide having KYC-sequence

    International Nuclear Information System (INIS)

    Takayama, T.; Suzuki, K.; Sekine, T.; Kudo, H.

    2000-01-01

    Technetium(V) and rhenium(V) oxo complexes of a peptide having a KYC-sequence such as KYCAR (H 3 L 5 ) and KYCAREPPTRTNAYQGQG-NH 2 (H 3 L 18 ) were synthesized, and structures of the complexes were characterized by spectroscopic techniques. All of the complexes were synthesized by the ligand exchange reaction of [(n-C 4 H 9 ) 4 N][MOCl 4 ] (M = 99 Tc, Re) with peptide in methanol or dimethylformamide solution. These complexes have a square pyramidal structure with an oxo ligand at the apical position. The peptide is coordinated to a metal atom through N amine of lysine. S thiol of cysteine, and N amide of tyrosine and cysteine in the equatorial plane. A lysine (CH 2 ) 4 NH 2 group of the L 5 ligand has the syn conformation with respect to metal-oxo bonding in the complex. The syn isomer was selectively formed in the ligand exchange reaction. The conversion of the syn isomer to the anti isomer was observed only for syn-[ReO(L 5 )], in which the coordination of water to the trans position of the oxo ligand was involved. (orig.)

  9. Development of a radiochemical neutron activation analysis procedure for determination of rhenium in biological and environmental samples at ultratrace level

    International Nuclear Information System (INIS)

    Kucera, J.; Lucanikova, M.; Czech Technical Univ., Prague

    2006-01-01

    Radiochemical neutron activation procedures using liquid-liquid extraction with tetraphenylarsonium chloride in chloroform from 1M HCl and solid extraction with ALIQUAT 336 incorporated in a polyacrylonitrile binding matrix from 0.1M HCl were developed for accurate determination of rhenium in biological and environmental samples at the sub-ng x g -1 level. Concentrations of Re in the range of 0.1 to 2.4 ng x g -1 were determined in several botanical reference materials (RM), while in a RM of road dust a value of ∼ 10 ng x g -1 was found. Significantly elevated values of Re, up to 90 ng x g -1 were found in seaweed (brown algae). Results for Re in the brown algae Fucus vesiculosus in which elevated 99 Tc values had previously been determined suggested possible competition between Re and Tc in the accumulation process. (author)

  10. Safety and Efficacy of 188-Rhenium-Labeled Antibody to Melanin in Patients with Metastatic Melanoma

    Directory of Open Access Journals (Sweden)

    M. Klein

    2013-01-01

    Full Text Available There is a need for effective “broad spectrum” therapies for metastatic melanoma which would be suitable for all patients. The objectives of Phase Ia/Ib studies were to evaluate the safety, pharmacokinetics, dosimetry, and antitumor activity of 188Re-6D2, a 188-Rhenium-labeled antibody to melanin. Stage IIIC/IV metastatic melanoma (MM patients who failed standard therapies were enrolled in both studies. In Phase Ia, 10 mCi 188Re-6D2 were given while unlabeled antibody preload was escalated. In Phase Ib, the dose of 188Re-6D2 was escalated to 54 mCi. SPECT/CT revealed 188Re-6D2 uptake in melanoma metastases. The mean effective half-life of 188Re-6D2 was 12.4 h. Transient HAMA was observed in 9 patients. Six patients met the RECIST criteria for stable disease at 6 weeks. Two patients had durable disease stabilization for 14 weeks and one for 22 weeks. Median overall survival was 13 months with no dose-limiting toxicities. The data demonstrate that 188Re-6D2 was well tolerated, localized in melanoma metastases, and had antitumor activity, thus warranting its further investigation in patients with metastatic melanoma.

  11. Rhenium(5) and molybdenum(5) complexes with 4',4[sup (]5[sup )]-divaleryldibenzo-18-crown-6. Kompleksnye soedineniya reniya(5) i molibdena(5) s 4',4[sup (]5[sup )]-divalerildibenzo-18-kraun-6

    Energy Technology Data Exchange (ETDEWEB)

    Ashurova, N Kh; Yakubov, K G; Tashmukhamedova, A K; Basitova, S M [Tadzhikskij Gosudarstvennyj Univ., Dushanbe (Tajikistan)

    1993-02-01

    Methods for synthesizing oxohalide complexes of rhenium and molybdenum with +5 oxidation degree with 4',4[sup (5)]-divaleryldibenzo-18-crown-6 were developed. Content and composition of prepared compounds were investigated by the methods of element analysis, crystal optics, conductometry, IR spectroscopy in the near and far regions, thermogravimetry. Oxidation degree of the complex-forming metal was determined. It was established that composition of the compounds coressponded to the general formula MOLX [sub [center dot

  12. Focused Ion Beam Nanotomography of ruthenium-bearing nickel-base superalloys with focus on cast-microstructure and phase stability; Focused Ion Beam Nanotomographie von rutheniumhaltigen Nickelbasis-Superlegierungen mit Fokus auf Gussgefuege und Phasenstabilitaet

    Energy Technology Data Exchange (ETDEWEB)

    Cenanovic, Samir

    2012-12-03

    The influence of rhenium and ruthenium on the multi component system nickel-base superalloy is manifold and complex. An experimental nickel-base superalloy containing rhenium and ruthenium within defined contents, named Astra, was used to investigate the influences of these two elements on the alloy system. The last stage solidification of nickel-base superalloys after Bridgman casting and the high temperature phase stability of these alloys, could be explored with the aid of focused ion beam nanotomography. FIB-nt therefore was introduced and realized at the chair of General Materials Properties of the University Erlangen-Nuremberg. Cast Astra alloys are like other nickel-base superalloys morphologically very inhomogeneous and affected by segregation. In the interdendritic region different structures with huge γ' precipitates are formed. These inhomogeneities and remaining eutectics degrade the mechanical properties, witch makes an understanding of the subsiding processes at solidification of residual melt important for the casting process and the heat treatment. This is why the last stage solidification in the interdendritic region was analyzed. With the help of focused ion beam nanotomography, three different structures identified from 2-D sections could be assigned to one original 3-D structure. It was pointed out, that only the orientation of the plane of the 2-D cut influences the appearance in the 2-D section. The tomography information was used to explain the development during solidification and to create a model of last stage solidification. The interdendritic region is solidifying under the development of eutectic islands. The structure nucleates eutectically epitaxially at primary dendrite arms, with formation of fine γ/γ' precipitates. During solidification the γ' precipitates coarsen in a rod-like structure, and end up in large γ' precipitates. Simulations and other investigations could approve this model. First three

  13. IFE chamber dry wall materials response to pulsed X-rays and ions at power-plant level fluences

    Energy Technology Data Exchange (ETDEWEB)

    Renk, T.J. E-mail: tjrenk@sandia.gov; Olson, C.L.; Tanaka, T.J.; Ulrickson, M.A.; Rochau, G.A.; Peterson, R.R.; Golovkin, I.E.; Thompson, M.O.; Knowles, T.R.; Raffray, A.R.; Tillack, M.S

    2003-04-01

    We have begun a collaborative investigation of the response of candidate first-wall inertial fusion energy (IFE) reactor chamber drywall materials to X-rays on the Z facility, and to ions on RHEPP-1, both located at Sandia National Laboratories. Dose levels are comparable to those anticipated in future direct-drive reactors. Due to the 5-10 Hz repetition rate expected in such reactors, per-pulse effects such as material removal must be negligible. The primary wall materials investigated here are graphite and tungsten in various forms. After exposure on either RHEPP or Z, materials were analyzed for roughening and/or material removal (ablation) as a function of dose. Graphite is observed to undergo significant ablation/sublimation in response to ion exposure at the 3-4 J/cm{sup 2} level, significantly below doses expected in future dry-wall power plants. Evidence of thermomechanical stresses resulting in material loss occurs for both graphite and tungsten, and is probably related to the pulsed nature of the energy delivery. These effects are not seen in typical magnetic fusion energy (MFE) conditions where these same kinds of materials are used. Results are presented for thresholds below which no roughening or ablation occurs. Use of graphite in a 'velvet' two-dimensional form may mitigate the effects seen with the flat material, and alloying tungsten with rhenium may reduce its roughening due to the increased ductility of the alloy.

  14. A new amperometric glucose biosensor based on screen printed carbon electrodes with rhenium(IV - oxide as a mediator

    Directory of Open Access Journals (Sweden)

    ALBANA VESELI

    2012-11-01

    Full Text Available Rhenium(IV-oxide, ReO2, was used as a mediator for carbon paste (CPE and screen printed carbon (SPCE electrodes for the catalytic amperometric determination of hydro-gen peroxide, whose overpotential for the reduction could be lowered to -0.1 V vs. Ag/AgCl in flow injection analysis (FIA using phosphate buffer (0.1 M, pH=7.5 as a carrier. For hydrogen peroxide a detection limit (3σ of 0.8 mg L-1 could be obtained.ReO2-modified SPCEs were used to design biosensors with a template enzyme, i.e. glucose oxidase, entrapped in a Nafion membrane. The resulting glucose sensor showed a linear dynamic range up to 200 mg L-1 glucose with a detection limit (3σ of 0.6 mg L-1. The repeatability was 2.1 % RSD (n = 5 measurements, the reproducibility 5.4 % (n = 5 sensors. The sensor could be applied for the determination of glucose in blood serum in good agreement with a reference method.

  15. Physico-chemical characterisation and biological evaluation of 188-Rhenium colloids for radiosynovectomy

    International Nuclear Information System (INIS)

    Ures, Ma Cristina; Savio, Eduardo; Malanga, Antonio; Fernández, Marcelo; Paolino, Andrea; Gaudiano, Javier

    2002-01-01

    Radiosynovectomy is a type of radiotherapy used to relieve pain and inflammation from rheumatoid arthritis. In this study, 188-Rhenium ( 188 Re) colloids were characterized by physical and biological methodologies. This was used to assess which parameters of the kit formulation would be the basis in the development of a more effective radiopharmaceutical for synovectomy. Intraarticular injection in knees of rabbits assessed cavity leakage of activity. The physical characteristics of tin (Sn) and sulphur (S) colloids were determined to assess the formulation with suitable properties. Particles were grouped in three ranges for analyzing their distribution according to their number, volume and surface. The ideal particle size range was considered to be from 2 to 10 microns. Membrane filtration and laser diffraction characterization methodologies were used. While membrane filtration could give misleading data, laser diffraction proportions more reliable results. The Sn colloid showed a better distribution of particle volume and surface than S colloid, in the 2 to 10 microns range. The 188 Re-Sn colloid was obtained with a radiochemical purity higher than 95% after 30 minutes of autoclaving. While Sn colloid kit stability was verified for 60 days, the 188 Re-Sn preparation was stable in the first 24 hrs. No significant intrabatch variability (n = 3) was detected. Biodistribution and scintigraphic studies in rabbits after intraarticular injection showed relevant activity only in knee, being 90% at 48 hours. The 188 Re-Sn colloid is easy to prepare, is stable for 24 hours and shows minimal cavity leakage after intraarticular injection into rabbit knees, suggesting this radiotherapeutical agent has suitable physical properties for evaluation for joint treatment in humans

  16. Evaluation of SuperLig 639 Ion Exchange Resin for the Removal of Rhenium from Hanford Envelope A Simulant

    International Nuclear Information System (INIS)

    King, W.D.

    2000-01-01

    Hanford Radioactive Waste materials have been categorized into four envelopes labeled A through D as specified in the Tank Waste Remediation Contract between BNFL and DOE. 1 Envelopes A, B and C contain only solubilized species and are specified as Low-Activity Waste (LAW). Each envelope is defined based on compositional maximums of chemical and radioactive constituents. Envelopes A and B contain low concentrations of organic species and the primary form of technetium is pertechnetate (TcO4-). Envelope C contains higher levels of organic species and technetium which is primarily in the nonpertechnetate form (presumably complexed TcO2). Envelope D is sludge which has been separated from the supernate and is referred to as High Activity Waste. The current plant design utilizes SuperLig ion exchange resins to remove cesium and technetium (the primary radioactive constituents) from the Hanford LAW. The process is designed to produce a decontaminated waste stream and a concentrated eluate waste stream for vitrification into low and high activity glasses, respectively

  17. Syntheses and structures of technetium(V) and rhenium(V) oxo complexes of peptide having KYC-sequence

    Energy Technology Data Exchange (ETDEWEB)

    Takayama, T.; Suzuki, K.; Sekine, T.; Kudo, H. [Dept. of Chemistry, Tohoku Univ., Sendai (Japan)

    2000-07-01

    Technetium(V) and rhenium(V) oxo complexes of a peptide having a KYC-sequence such as KYCAR (H{sub 3}L{sup 5}) and KYCAREPPTRTNAYQGQG-NH{sub 2} (H{sub 3}L{sup 18}) were synthesized, and structures of the complexes were characterized by spectroscopic techniques. All of the complexes were synthesized by the ligand exchange reaction of [(n-C{sub 4}H{sub 9}){sub 4}N][MOCl{sub 4}] (M = {sup 99}Tc, Re) with peptide in methanol or dimethylformamide solution. These complexes have a square pyramidal structure with an oxo ligand at the apical position. The peptide is coordinated to a metal atom through N{sub amine} of lysine. S{sub thiol} of cysteine, and N{sub amide} of tyrosine and cysteine in the equatorial plane. A lysine (CH{sub 2}){sub 4}NH{sub 2} group of the L{sup 5} ligand has the syn conformation with respect to metal-oxo bonding in the complex. The syn isomer was selectively formed in the ligand exchange reaction. The conversion of the syn isomer to the anti isomer was observed only for syn-[ReO(L{sup 5})], in which the coordination of water to the trans position of the oxo ligand was involved. (orig.)

  18. Bone marrow adsorbed dose of rhenium-186-HEDP and the relationship with decreased platelet counts

    International Nuclear Information System (INIS)

    Klerk, J.M.H. de; Dieren, E.B. van; Schip, A.D. van het

    1996-01-01

    Rhenium-186(Sn)-1,1-hydroxyethylidene diphosphonate ( 186 Re-HEDP) has been used for palliation of metastatic bone pain. The purpose of this study was to find a relationship between the bone marrow absorbed dose and the toxicity, expressed as the percentage decrease in the peripheral blood platelet count. The bone marrow absorbed dose was calculated according to the MIRD model using data obtained from ten treatments of patients suffering from metastatic prostate cancer; noninvasive and pharmacokinetic method were used. The bone marrow doses were related to toxicity using the pharmacodynamic sigmoid E max model. The mean bone marrow absorbed doses using the noninvasive and pharmacokinetic methods were in a close range to each other (1.07 mGy/MBq and 1.02 mGy/MBq, respectively). There was a good relationship between the toxicity and the bone marrow absorbed dose (r = 0.80). Furthermore, the EDrm 50 (i.e., the bone marrow absorbed dose producing a 50% platelet decrease) to bone marrow for 186 Re-HEDP was on the order of 2 Gy. Although the function of normal bone marrow is affected by metastases in patients with metastatic bone disease, the MIRD model can be used to relate toxicity to the bone marrow absorbed dose after a therapeutic dosage of 186 Re-HEDP. 33 refs., 1 fig., 1 tab

  19. New ternary oxides with rhenium(4) of the perovskite structure

    Energy Technology Data Exchange (ETDEWEB)

    Jezowska-Trzebiatowska, B; Nowakowski, T; Mrozinski, J [Wroclaw Univ. (Poland)

    1978-01-01

    A series of ternary oxides described by general formula CaIrsub(x)Resub(1-x)O/sub 3/, where x 0.25; 0.33; 0.66; 0.75, has been obtained. The X-ray investigations have shown, that these compounds have a distorted perovskite structure. The proximal coordination sphere of Re/sup 4 +/ and Ir/sup 4 +/ ions constituted by an octahedron of oxide ions was confirmed by the IR spectra.

  20. Testing of electroformed deposited iridium/powder metallurgy rhenium rockets

    Science.gov (United States)

    Reed, Brian D.; Dickerson, Robert

    1996-01-01

    High-temperature, oxidation-resistant chamber materials offer the thermal margin for high performance and extended lifetimes for radiation-cooled rockets. Rhenium (Re) coated with iridium (Ir) allow hours of operation at 2200 C on Earth-storable propellants. One process for manufacturing Ir/Re rocket chambers is the fabrication of Re substrates by powder metallurgy (PM) and the application of Ir coatings by using electroformed deposition (ED). ED Ir coatings, however, have been found to be porous and poorly adherent. The integrity of ED Ir coatings could be improved by densification after the electroforming process. This report summarizes the testing of two 22-N, ED Ir/PM Re rocket chambers that were subjected to post-deposition treatments in an effort to densify the Ir coating. One chamber was vacuum annealed, while the other chamber was subjected to hot isostatic pressure (HIP). The chambers were tested on gaseous oxygen/gaseous hydrogen propellants, at mixture ratios that simulated the oxidizing environments of Earth-storable propellants. ne annealed ED Ir/PM Re chamber was tested for a total of 24 firings and 4.58 hr at a mixture ratio of 4.2. After only 9 firings, the annealed ED Ir coating began to blister and spall upstream of the throat. The blistering and spalling were similar to what had been experienced with unannealed, as-deposited ED Ir coatings. The HIP ED Ir/PM Re chamber was tested for a total of 91 firings and 11.45 hr at mixture ratios of 3.2 and 4.2. The HIP ED Ir coating remained adherent to the Re substrate throughout testing; there were no visible signs of coating degradation. Metallography revealed, however, thinning of the HIP Ir coating and occasional pores in the Re layer upstream of the throat. Pinholes in the Ir coating may have provided a path for oxidation of the Re substrate at these locations. The HIP ED Ir coating proved to be more effective than vacuum annealed and as-deposited ED Ir. Further densification is still required to

  1. Separation of carrier-free 181Re produced in 16O-irradiated thulium target

    International Nuclear Information System (INIS)

    Lahiri, Susanta; Mukhopadhyay, Krishnendu; Banerjee, Kakoli; Ramaswami, A.; Manohar, S.B.

    2001-01-01

    Heavy ion activation of natural Tm 2 O 3 with 90 MeV 16 O beam results in the formation of carrier-free short-lived 181 Ir and 181 Os which ultimately decay out to 181 Re in the matrix. The liquid cation exchanger, HDEHP, has effectively been utilized as an extractant for quantitative separation of bulk thulium target matrix from carrier-free rhenium radionuclide

  2. Tungsten-188/carrier-free rhenium-188 perrhenic acid generator system

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Lisic, E.C.; Mirzadeh, S.; Callahan, A.P.

    1993-01-01

    A generator system for providing a carrier-free radioisotope in the form of an acid comprises a chromatography column in tandem fluid connection with an ion exchange column, the chromatography column containing a charge of a radioactive parent isotope. The chromatography column, charged with a parent isotope, is eluted with an alkali metal salt solution to generate the radioisotope in the form of an intermediate solution, which is passed through the ion-exchange column to convert the radioisotope to a carrier-free acid form

  3. Chromatographic 188W →188Re generator

    International Nuclear Information System (INIS)

    Khujaev, S.

    2005-01-01

    Full text: The main purpose of the generator - reception of daughter radioisotope Rhenium-188 from it by periodic elution for a long period of time (more than half-year). It is generally known that Rhenium-188, in the form of its complex connections, is applied in nuclear medicine in treatment and removal of painful syndromes. The generator possesses convenient nuclear-physical characteristics of a daughter radioisotope Rhenium-188. It is a source of (Irradiation with energy 2.12 MeV (98 %) with small contribution soft γ-radiation with energy 0.155 MeV (15 %). The Period of half-life destruction of radioisotope is 17 hours. The 188 W parent radioisotope for the generator is formed by irradiation of 186 W neutrons based on the following reaction: 186 W (n,γ) 187 W (n,γ) 188 W (69 days) → 188 Re (17 hours) + β The following were used as targets for irradiation: 1) Metal Tungsten (powder) of natural structure; 2) Metal Tungsten (plate) of natural structure; 3) Metal Tungsten (wire) of natural structure, d = 12 mm; 4) Metal Tungsten (powder) with enrichment on isotope 186 W - 99.79 %. The irradiated material was exposed to chemical processing with reception of radioactive solution of tungsten-188, from which sorption Tungsten was carried out onto sorbent as poly-wolframate-ions. It is established that Tungsten sorption depends on many factors as there are various chemical forms of Tungsten (VI) in water solutions, ratio of which depends on pH of the solution, concentration of Tungsten in the solution and presence of foreign ions. Tungsten sorption was carried out in static and in dynamic regimes. At dynamic regime the sorbent was placed directly in the generating column. The generator consisted of chromatographic columns with sorbent and radioisotope 188 W, eluting system and radiation protection. Rhenium-188 was taken from the generator as perrhenate sodium by elution of 0.9 % solution of chloride sodium in 10 ml. Technical characteristics of the generator

  4. Focused Ion Beam Nanotomography of ruthenium-bearing nickel-base superalloys with focus on cast-microstructure and phase stability

    International Nuclear Information System (INIS)

    Cenanovic, Samir

    2012-01-01

    The influence of rhenium and ruthenium on the multi component system nickel-base superalloy is manifold and complex. An experimental nickel-base superalloy containing rhenium and ruthenium within defined contents, named Astra, was used to investigate the influences of these two elements on the alloy system. The last stage solidification of nickel-base superalloys after Bridgman casting and the high temperature phase stability of these alloys, could be explored with the aid of focused ion beam nanotomography. FIB-nt therefore was introduced and realized at the chair of General Materials Properties of the University Erlangen-Nuremberg. Cast Astra alloys are like other nickel-base superalloys morphologically very inhomogeneous and affected by segregation. In the interdendritic region different structures with huge γ' precipitates are formed. These inhomogeneities and remaining eutectics degrade the mechanical properties, witch makes an understanding of the subsiding processes at solidification of residual melt important for the casting process and the heat treatment. This is why the last stage solidification in the interdendritic region was analyzed. With the help of focused ion beam nanotomography, three different structures identified from 2-D sections could be assigned to one original 3-D structure. It was pointed out, that only the orientation of the plane of the 2-D cut influences the appearance in the 2-D section. The tomography information was used to explain the development during solidification and to create a model of last stage solidification. The interdendritic region is solidifying under the development of eutectic islands. The structure nucleates eutectically epitaxially at primary dendrite arms, with formation of fine γ/γ' precipitates. During solidification the γ' precipitates coarsen in a rod-like structure, and end up in large γ' precipitates. Simulations and other investigations could approve this model. First three

  5. Sorption of technetium and its analogue rhenium on bentonite material under aerobic conditions

    International Nuclear Information System (INIS)

    Vinsova, H.; Koudelkova, M.; Konirova, R.; Vecernik, P.; Jedinakova-Krizova, V.

    2003-01-01

    The uptake of technetium on bentonite materials has been studied from the point of view of characterization of long-term radioactive elements behavior in nuclear waste repository. Bentonite R (locality Rokle, Czech Republic) and two types of model groundwater (granitic and bentonite) were selected for the sorption experiments. It is generally known that bentonite materials show an excellent cation-exchange capacity and, on the other hand, a poor uptake of anions. Technetium occurs under aerobic conditions in its most stable oxidation state (+VII) as pertechnetate, which makes a question of its sorption on bentonite more complex when compared with e.g. Cs + or Sr 2+ . To increase the K d values for technetium sorption on bentonite, it is necessary to carry out the experiments under anaerobic conditions in the presence of reducing agent, which is capable to lower the oxidation state of technetium which enables its successful immobilization. The aim of our research has been to find out the conditions suitable for the technetium sorption on selected bentonite under oxidizing conditions. The sorption experiments with Tc-99 on bentonite have been carried out by batch method. The influence of the addition of different materials (e.g. activated carbon, graphite, Fe 2+ , Fe) with bentonite, the effect of solid:aqueous phase ratio and a pH value on the percentage of technetium uptake and on the K d values were tested. Perrhenate was selected as an analogue of pertechnetate in non-active experiments of capillary electrophoresis (CE) and isotachophoresis (ITP). The percentage of rhenium sorbed on bentonite material was determined from the decrease of perrhenate peak area (CE) and from the shortening of the ITP zone corresponding to perrhenate. Both electromigration methods provided comparable results. The results obtained in this study with non-active material were compared to those of technetium acquired by radiometry and polarography. (authors)

  6. Comparative study of the anchorage and the catalytic properties of nanoporous TiO2 films modified with ruthenium (II) and rhenium (I) carbonyl complexes

    Science.gov (United States)

    Oyarzún, Diego P.; Chardon-Noblat, Sylvie; Linarez Pérez, Omar E.; López Teijelo, Manuel; Zúñiga, César; Zarate, Ximena; Shott, Eduardo; Carreño, Alexander; Arratia-Perez, Ramiro

    2018-02-01

    In this article we study the anchoring of cis-[Ru(bpyC4pyr)(CO)2(CH3CN)2]2+, cis-[Ru(bpy)2(CO)2]2+ and cis-[Ru(bpyac)(CO)2Cl2], onto nanoporous TiO2 employing electropolymerization, electrostatic interaction and chemical bonding. Also, the [Re(bpyac)(CO)3Cl] rhenium(I) complex for chemical anchorage was analyzed. The characterization of TiO2/Ru(II) and TiO2/Re(I) nanocomposite films was performed by field emission scanning electron microscopy (FESEM), electron dispersive X-ray spectroscopy (EDS) and Raman spectroscopy. In addition, for the more stable nanocomposites obtained, the catalytic properties (solar energy conversion and CO2 reduction) were evaluated. The efficiency improvement in redox process derived from the (photo)electrochemical evidence indicates that modified nanoporous TiO2 structures enhance the rate of charge transfer reactions.

  7. Ion-ion collisions and ion storage rings

    International Nuclear Information System (INIS)

    Mowat, J.R.

    1988-01-01

    Improved understanding of fundamental ion-ion interactions is expected to emerge from research carried out with ion storage rings. In this short survey the significant advantages and unique features that make stored ions useful targets for collision experiments are reviewed and discussed. It is pointed out that improvements to existing ion-ion experiments, as well as qualitatively new experiments, should occur over the next few years as ion storage rings become available for atomic physics. Some new experiments are suggested which are difficult if not impossible with present-day technology, but which seem feasible at storage rings facilities. (orig.)

  8. Residency of rhenium and osmium in a heavy crude oil

    Science.gov (United States)

    DiMarzio, Jenna M.; Georgiev, Svetoslav V.; Stein, Holly J.; Hannah, Judith L.

    2018-01-01

    Rhenium-osmium (Re-Os) isotope geochemistry is an emerging tool for the study of oil formation and migration processes, and a new technology for petroleum exploration. Little is known, however, about the residency of Re and Os within asphaltene and maltene sub-fractions of crude oil. This information is crucial for understanding the 187Re-187Os radiometric clock held in petroleum systems and for interpreting geochronology for key processes such as oil formation, migration, and biodegradation. In this study, a heavy crude oil was separated into soluble (maltene, MALT) and insoluble (asphaltene, ASPH) fractions using n-heptane as the asphaltene-precipitating agent. The asphaltenes were separated sequentially into sub-fractions using two different solvent pairs (heptane-dichloromethane and acetone-toluene), and the bulk maltenes were separated into saturate, aromatic, and resin (SAR) fractions using open column chromatography. Each asphaltene and maltene sub-fraction was analyzed for Re and Os. The asphaltene sub-fractions and the bulk ASPH, MALT, and crude oil were analyzed for a suite of trace metals by ICP-MS. Our results show that Re and Os concentrations co-vary between the asphaltene sub-fractions, and that both elements are found mostly in the more polar and aromatic sub-fractions. Significant Re and Os are also present in the aromatic and resin fractions of the maltenes. However, each asphaltene and maltene sub-fraction has a distinct isotopic composition, and sub-fractions are not isochronous. This suggests that asphaltene sub-fractionation separates Re-Os complexes to the point where the isotopic integrity of the geochronometer is compromised. The mobility of individual Re and Os isotopes and the decoupling possibilities between radiogenic 187Os produced from 187Re remain elusive, but their recognition in this study is a critical first step. Re and Os correlate strongly with Mo and Cd in the asphaltene sub-fractions, suggesting that these metals occupy

  9. Fabrication of Tungsten-Rhenium Cladding materials via Spark Plasma Sintering for Ultra High Temperature Reactor Applications

    Energy Technology Data Exchange (ETDEWEB)

    Charit, Indrajit; Butt, Darryl; Frary, Megan; Carroll, Mark

    2012-11-05

    This research will develop an optimized, cost-effective method for producing high-purity tungsten-rhenium alloyed fuel clad forms that are crucial for the development of a very high-temperature nuclear reactor. The study will provide critical insight into the fundamental behavior (processing-microstructure- property correlations) of W-Re alloys made using this new fabrication process comprising high-energy ball milling (HEBM) and spark plasma sintering (SPS). A broader goal is to re-establish the U.S. lead in the research field of refractory alloys, such as W-Re systems, with potential applications in very high-temperature nuclear reactors. An essential long-term goal for nuclear power is to develop the capability of operating nuclear reactors at temperatures in excess of 1,000K. This capability has applications in space exploration and some special terrestrial uses where high temperatures are needed in certain chemical or reforming processes. Refractory alloys have been identified as being capable of withstanding temperatures in excess of 1,000K and are considered critical for the development of ultra hightemperature reactors. Tungsten alloys are known to possess extraordinary properties, such as excellent high-temperature capability, including the ability to resist leakage of fissile materials when used as a fuel clad. However, there are difficulties with the development of refractory alloys: 1) lack of basic experimental data on thermodynamics and mechanical and physical properties, and 2) challenges associated with processing these alloys.

  10. Dissimilar behavior of technetium and rhenium in borosilicatewaste glass as determined by X-ray absorption spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lukens, Wayne W.; McKeown, David A.; Buechele, Andrew C.; Muller,Isabelle S.; Shuh, David K.; Pegg, Ian L.

    2006-11-09

    Technetium-99 is an abundant, long-lived (t1/2 = 213,000 yr)fission product that creates challenges for the safe, long-term disposalof nuclear waste. While 99Tc receives attention largely due to its highenvironmental mobility, it also causes problems during its incorporationinto nuclear waste glass due to the volatility of Tc(VII) compounds. Thisvolatility decreases the amount of 99Tc stabilized in the waste glass andcauses contamination of the waste glass melter and off-gas system. Theapproach to decrease the volatility of 99Tc that has received the mostattention is reduction of the volatile Tc(VII) species to less volatileTc(IV) species in the glass melt. On engineering scale experiments,rhenium is often used as a non-radioactive surrogate for 99Tc to avoidthe radioactive contamination problems caused by volatile 99Tc compounds.However, Re(VII) is more stable towards reduction than Tc(VII), so morereducing conditions would be required in the glass melt to produceRe(IV). To better understand the redox behavior of Tc and Re in nuclearwaste glass, a series of glasses were prepared under different redoxconditions. The speciation of Tc and Re in the resulting glasses wasdetermined by X-ray absorption fine structure spectroscopy. Surprisingly,Re and Tc do not behave similarly in the glass melt. Although Tc(0),Tc(IV), and Tc(VII) were observed in these samples, only Re(0) andRe(VII) were found. In no case was Re(IV) (or Re(VI))observed.

  11. Electronic structures and properties of the rhenium alkoxy derivatives Re2O3(OMe)6, Re4O6(OMe)12, and ReMoO2(OMe)7

    International Nuclear Information System (INIS)

    Ermakov, A.I.; Belousov, V.V.; Drobot, D.V.; Shcheglov, P.A.

    2006-01-01

    The geometrical structures, charge distributions, dipole moments, frequencies of normal vibrations, NMR spectra, and total energies of the chemical bonds for the rhenium alkoxy derivatives Re 2 O 3 (OMe) 6 , Re 4 O 6 (OMe) 12 , and ReMoO 2 (OMe) 7 were calculated by the DFT-B3LYP and Hartree-Fock ab initio methods based on the effective core potential theory (LANL2DZ approximation) and the semiempirical PM3(tm) method. Two optimized structures of Re 2 O 3 (OMe) 6 with close energies were found to substantially differ in geometry, 1 H, 13 C, and 17 O NMR spectra, and dipole moment. Various characteristics of the electronic structures and the trans-effect of the ligands in the compounds under consideration were discussed [ru

  12. Heating tokamaks via the ion-cyclotron and ion-ion hybrid resonances

    International Nuclear Information System (INIS)

    Perkins, F.W.

    1977-04-01

    For the ion-ion hybrid resonance it is shown that: (1) the energy absorption occurs via a sequence of mode conversions; (2) a poloidal field component normal to the ion-ion hybrid mode conversion surface strongly influences the mode conversion process so that roughly equal electron and ion heating occurs in the present proton-deuterium experiments, while solely electron heating is predicted to prevail in deuterium-tritium reactors; (3) the ion-ion hybrid resonance suppresses toroidal eigenmodes; and (4) wave absorption in minority fundamental ion-cyclotron heating experiments will be dominated by ion-ion hybrid mode conversion absorption for minority concentrations exceeding roughly 1 percent. For the ion-cyclotron resonance, it is shown that: (1) ion-cyclotron mode conversion leads to surface electron heating; and (2) ion-cyclotron mode conversion absorption dominates fundamental ion-cyclotron absorption thereby preventing efficient ion heating

  13. Determination of rhenium content in molybdenite by ICP-MS after separation of the major matrix by solvent extraction with N-benzoyl-N-phenylhydroxalamine.

    Science.gov (United States)

    Li, Jie; Zhong, Li-feng; Tu, Xiang-lin; Liang, Xi-rong; Xu, Ji-feng

    2010-05-15

    A simple and rapid analytical method for determining the concentration of rhenium in molybdenite for Re-Os dating was developed. The method used isotope dilution-inductively coupled plasma-mass spectrometry (ID-ICP-MS) after the removal of major matrix elements (e.g., Mo, Fe, and W) from Re by solvent extraction with N-benzoyl-N-phenylhydroxylamine (BPHA) in chloroform solution. The effect on extraction efficiency of parameters such as pH (HCl concentration), BPHA concentration, and extraction time were also assessed. Under the optimal experimental conditions, the validity of the separation method was accessed by measuring (187)Re/(185)Re values for a molybdenite reference material (JDC). The obtained values were in good agreement with previously measured values of the Re standard. The proposed method was applied to replicate Re-Os dating of JDC and seven samples of molybdenite from the Yuanzhuding large Cu-Mo porphyry deposit. The results demonstrate good precision and accuracy for the proposed method. The advantages of the method (i.e., simplicity, efficiency, short analysis time, and low cost) make it suitable for routine analysis.

  14. Evaluation of technetium-99m/rhenium labelled nucleoside analogues as potential radiotracers in oncology

    International Nuclear Information System (INIS)

    Desbouis, D.

    2007-01-01

    cell uptake in transfected cancer cells this technetium thymidine complex revealed a low internalisation of 0.03 ± 0.01%ID/(mg/mL). Under the same conditions the [ 3 H]thymidine exhibited an uptake of 1.50 ± 0.02%lD/(mg/mL). In order to gain potency and selectivity for HSV1-TK, the corresponding 5'-carboxamide 5-ethyl-2', 5'-dideoxyuridine was synthesized. The synthesis of the ligand was performed in seven steps from 2'-deoxyuridine. This ligand was then successfully labelled with the fac-M(CO) 3 -core (M = 99m Tc, Re). The rhenium complex was found to be a selective competitive inhibitor of HSV1-TK (K i = 4.56 ± 0.11 μM). Although the cellular uptake of the technetium 2'-deoxyurine complex (0.10 ± 0.01%ID/(mg/mL)) was better than its corresponding technetium thymidine complex, it is still very low compared to thymidine uptake. The second aspect of this work was to develop nucleoside derivatives labelled with technetium-99m/rhenium tricarbonyl core capable of acting as substrates for human cytosolic thymidine kinase (hTKl). hTKl is a target of choice to evaluate cell proliferation due to its overexpression in a variety of cancer cells. [ 18 F]Fluorothymidine [ 18 F]FLT), which acts as a hTKl substrate, has emerged as a very efficient PET tracer for the monitoring of cell proliferation. Our aim was to develop a SPET tracer with the same mode of action as [ 18 F]FLT. We prepared a set of technetium-99m/rhenium complexes of N3 thymidine derivatives with different overall charges (+1, 0 and -1) and variable spacer lengths. The complexes with different overall charges had the same spacer length between chelating system and thymidine moiety (two carbons spacer) while the complexes with different spacer lengths (2, 3, 5 and 10) were all neutral. These compounds were tested for their substrate activity with respect to recombinant hTKl. The phosphorylation rates of neutral and negative complexes were found to be similar, ranging between 15-16% with respect to thymidine

  15. Preliminary results of transarterial Rhenium-188 HDD Lipiodol in treatment of inoperable primary hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Sundram, Felix

    2004-01-01

    Full text: In this paper we present our early experience with a new radio-conjugate, namely rhenium-188 HDD Lipiodol (Re-188 lipiodol). Imported radiopharmaceuticals are generally expensive, particularly for developing countries. A Tungsten (W-188-Re 188) generator obtained from ORNL (Oak Ridge National Laboratory, Tennessee, USA) allows us on-site production of a beta emitting therapeutic isotope (Re-188) for up to 6 months from a single generator. The objectives of this study were to establish the safety of trans-arterial Re-188 lipiodol in patients with inoperable HCC, and determine the adverse effects and efficacy for this radio-conjugate treatment in a multi-center study of patients with advanced HCC. A multi-center study was sponsored by the International Atomic Energy Agency (Vienna) to assess the safety and efficacy of trans-arterial Re-188 HDD conjugated lipiodol (radio-conjugate) in the treatment of patients with inoperable hepatocellular carcinoma (HCC), The radio-conjugate was prepared by using a HDD (4-hexadecyl 1-2, 9, 9-tetramethyl-4, 7-diaza-1, 10-decanethiol) kit developed in Korea, and lipiodol. Over a period of eighteen months seventy patients received at least one treatment of radio-conjugate. Some patients were re-treated if there was no evidence of disease progression. The level of radio-conjugate administered was based on radiation-absorbed dose to critical normal organs, calculated following a 'scout' dose of radio-conjugate. The organs at greatest risk for radiation toxicity are the normal liver, the lung and the bone marrow. A specially designed spreadsheet was used to determine maximum tolerated activity (MTA), defined as the amount of radioactivity calculated to deliver no more than 12 Gray (Gy) to lungs, or 30 Gy to liver, or 1.5 Gy to bone marrow. These doses have been found to be safe in multiple trials using external beam therapy and systemically administered radiopharmaceuticals. Patients were followed for at least twelve weeks

  16. Metal cyanides

    International Nuclear Information System (INIS)

    Wells, A.F.

    1988-01-01

    From the biewpoint of general crystal T chemistry principles and on the basis of modern data the structural chemistry of metal cyanites is presented. The features of the structure of the following compounds are considered: simple ionic alkali cyanides (Li-Cs) containing CN - ions; molybdenum (4,5), tungsten (4,5), rhenium (5,6) complexes etc, where-CN group is only connected with one metal atom; covalent cyanides of cadmium and other elements in which the CN-group serves as a bridge

  17. Pyrazole complexes of rhenium. Synthesis and crystal structure of trans-[Re(O)(OMe)L4]Br2 · L · 4H2O (L - 3,5-dimethylpyrazole)

    International Nuclear Information System (INIS)

    Sokolov, M.N.; Fedorova, N.Eh.; Fedorov, V.E.; Virovets, A.V.; Nun'es, P.

    2002-01-01

    The first rhenium (V) mononuclear complex featuring composition [Re(O)(OMe)L 4 ]Br 2 (L = 3,5-dimethylpyrazole), which is resistant to hydrolysis in neutral aqueous solution, along with its molecular adduct of the composition [Re(O)(OMe)L 4 ]Br 2 · L · 4H 2 O were synthesized. The reaction products were characterized by the methods of elementary analysis, absorption spectroscopy in visible, UV and IR ranges, mass spectrometry. Besides, the adduct structure was studied by the method of X-ray diffraction analysis. It was ascertained that the adduct is crystallized in tetragonal crystal system with unit cell parameters as follows: a = 14.912 (3), c = 17.108 (4) A, sp. gr. I4/m, Z = 4. In the complex molecule linear grouping Re(O)(OMe)] 2+ (Re-O-C angle being equal to 180 deg) is coordinated by four L ligand molecules [ru

  18. Calculation of ion storage in electron beams with account of ion-ion interactions

    International Nuclear Information System (INIS)

    Perel'shtejn, Eh.A.; Shirkov, G.D.

    1979-01-01

    Ion storage in relativistic electron beams was calculated taking account of ion-ion charge exchange and ionization. The calculations were made for nitrogen ion storage from residual gas during the compression of electron rings in the adhezator of the JINR heavy ion accelerator. The calculations were made for rings of various parameters and for various pressures of the residual gas. The results are compared with analogous calculations made without account of ion-ion processes. It is shown that at heavy loading of a ring by ions ion-ion collisions play a significant part, and they should be taken into account while calculating ion storage

  19. Analysis of barium by isotope mass spectrometry

    International Nuclear Information System (INIS)

    Long Kaiming; Jia Baoting; Liu Xuemei

    2004-01-01

    The isotopic abundance ratios for barium at sub-microgram level are analyzed by thermal surface ionization mass spectrometry (TIMS). Rhenium trips used for sample preparation are firstly treated to eliminate possible barium background interference. During the preparation of barium samples phosphoric acid is added as an emitting and stabilizing reagent. The addition of phosphoric acid increases the collection efficiency and ion current strength and stability for barium. A relative standard deviation of 0.02% for the isotopic abundance ratio of 137 Ba to 138 Ba is achieved when the 138 Ba ion current is (1-3) x 10 -12 A. The experimental results also demonstrate that the isotope fractionation effect is negligibly small in the isotopic analysis of barium

  20. Ion-Ion Plasmas Produced by Electron Beams

    Science.gov (United States)

    Fernsler, R. F.; Leonhardt, D.; Walton, S. G.; Meger, R. A.

    2001-10-01

    The ability of plasmas to etch deep, small-scale features in materials is limited by localized charging of the features. The features charge because of the difference in electron and ion anisotropy, and thus one solution now being explored is to use ion-ion plasmas in place of electron-ion plasmas. Ion-ion plasmas are effectively electron-free and consist mainly of positive and negative ions. Since the two ion species behave similarly, localized charging is largely eliminated. However, the only way to produce ion-ion plasmas at low gas pressure is to convert electrons into negative ions through two-body attachment to neutrals. While the electron attachment rate is large at low electron temperatures (Te < 1 eV) in many of the halogen gases used for processing, these temperatures occur in most reactors only during the afterglow when the heating fields are turned off and the plasma is decaying. By contrast, Te is low nearly all the time in plasmas produced by electron beams, and therefore electron beams can potentially produce ion-ion plasmas continuously. The theory of ion-ion plasmas formed by pulsed electron beams is examined in this talk and compared with experimental results presented elsewhere [1]. Some general limitations of ion-ion plasmas, including relatively low flux levels, are discussed as well. [1] See the presentation by D. Leonhardt et al. at this conference.

  1. Analysis of a rhenium-osmium solid-solution spike by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Richardson, J.M.; Dickin, A.P.; McNutt, R.H.; McAndrew, J.I.; Beneteau, S.B.

    1989-01-01

    The rhenium-osmium decay scheme ( 187 Re → 187 Os) offers a unique opportunity to investigate the genesis of, and directly date, ultramafic rock, sulphide and platinum ore deposits. Inductively coupled plasma mass spectrometry (ICP-MS) is a viable method for Os isotopic analysis as it provides the high temperatures necessary to ionise Os. The sample can be introduced into the ICP mass spectrometer either by conventional nebulisation or by distillation using an Os ''generator''. Generator-mode analysis is superior to nebulisation because (i) the total number of counts is two orders of magnitude higher for a given sample size and (ii) Os oxidises readily to volatile OsO 4 , which has a boiling-point lower than most Re compounds, so that Os can be efficiently separated from 187 Re. The importance of Os loss during sample preparation was minimised by combining the sample powder with a powdered Re-Os isotopic spike prior to any chemical treatment. The spike is in a nickel sulphide matrix and was made by a thioacetamide co-precipitation of Os, Re and Ni followed by a fire assay. The 190 Os/ 192 Os ratio in this preparation is 51.5 ± 0.9, the 187 Os 188 Os ratio is 0.063 ± 0.006 and the 185 Re/ 187 Re ratio is 17.04 - + 0.41. These values are within the error limits quoted by the Oak Ridge National Laboratory and Techsnabexport, the suppliers of the metallic spikes. Parameters that significantly influence the Os analyses include the oxidising agent and the run temperature. The oxidising agent H 5 IO 6 is preferred to H 2 O 2 or HNO 3 as it has the highest electrode potential, provides a prolonged, consistent reaction and is more stable when stored. Chilling the sample and the H 5 IO 6 , initially retards uncontrolled OsO 4 emission. Heat applied later in the run releases OsO 4 and helps maintain a high count rate. Thus, OsO 4 can be generated in a steady, controllable and reproducible manner. (author)

  2. Majority ion heating near the ion-ion hybrid layer in tokamaks

    International Nuclear Information System (INIS)

    Phillips, C.K.; Hosea, J.C.; Ignat, D.; Majeski, R.; Rogers, J.H.; Schilling, G.; Wilson, J.R.

    1995-08-01

    Efficient direct majority ion heating in a deuterium-tritium (D-T) reactor-grade plasma via absorption of fast magnetosonic waves in the ion cyclotron range of frequencies (ICRF) is discussed. Majority ion heating results from resonance overlap between the cyclotron layers and the D-T ion-ion hybrid layer in hot, dense plasmas for fast waves launched with high parallel wavenumbers. Analytic and numerical models are used to explore the regime in ITER plasmas

  3. Rhenium-188 - advantages and clinical potential for use of a readily available, cost effective therapeutic radioisotope for applications in nuclear medicine, oncology and interventional cardiology

    International Nuclear Information System (INIS)

    Knapp, F.F. jr.

    2002-01-01

    Full text: Carrier-free rhenium-188 (Re-188) is readily available from the alumina-based tungsten-188/rhenium-188 generator system and has many attractive properties for a wide variety of therapeutic applications. The 16.9 h half-life, emission of the 2.2 MeV beta particle and versatile chemistry make Re-188 an important candidate for applications where high radiation penetration is required. In addition, emission of a gamma photon (155 KeV, 15 %) permits evaluation of biodistribution, pharmacokinetics and dosimetry estimates. The long physical half-life of the tungsten-188 (W-188) parent (t 1/2 69 days) and consistent generator performance - with high Re-188 yields and low W-188 parent breakthrough - result in an indefinite shelf-life of several months, dependent on the levels of Re-188 required. Post generator elution in-growth of 62 % of Re-188 after 24 hours in combination with high elution yields (75-85 %) result in 50 % daily yields of the maximal Re-188 available. In addition to research being conducted for the development of a wide variety of new therapeutic radiopharmaceuticals and devices, Re-188 is also being evaluated in physician-sponsored clinical trials in over 15 countries, with applications in nuclear medicine, oncology and interventional cardiology. One major current clinical application involves post-angiographic treatment of arterial segments following PTCA using Re-188 perrhenate or MAG3 liquid-filled balloons as an effective and cost-effective approach for inhibition of the hyperplastic response to vessel damage, which delivers uniform dose to the vessel wall. Re-188-HEDP is being used for palliation of metastatic bone pain palliation. This agent is readily prepared from a simple 'kit' and provides pain palliation as effective as other commercially available agents. The use of the Re-188-labeled Anti-NCA-95 antibody (BW 50/183; CD66 a,b,c,e) in conjunction which external beam irradiation and chemotherapy is an effective method for

  4. An RF ion source based primary ion gun for secondary ion mass spectroscopy

    International Nuclear Information System (INIS)

    Menon, Ranjini; Nabhiraj, P.Y.; Bhandari, R.K.

    2011-01-01

    In this article we present the design, development and characterization of an RF plasma based ion gun as a primary ion gun for SIMS application. RF ion sources, in particular Inductively Coupled Plasma (ICP) ion sources are superior compared to LMIS and duoplasmtron ion sources since they are filamentless, can produce ions of gaseous elements. At the same time, ICP ion sources offer high angular current density which is an important factor in producing high current in small spot size on the target. These high current microprobes improve the signal to noise ratio by three orders as compared to low current ion sources such as LMIS. In addition, the high current microprobes have higher surface and depth profiling speeds. In this article we describe a simple ion source in its very basic form, two lens optical column and characteristics of microprobe

  5. Ion mixing and numerical simulation of different ions produced in the ECR ion source

    International Nuclear Information System (INIS)

    Shirkov, G.D.

    1996-01-01

    This paper is to continue theoretical investigations and numerical simulations in the physics of ECR ion sources within the CERN program on heavy ion acceleration. The gas (ion) mixing effect in ECR sources is considered here. It is shown that the addition of light ions to the ECR plasma has three different mechanisms to improve highly charged ion production: the increase of confinement time and charge state of highly ions as the result of ion cooling; the concentration of highly charged ions in the central region of the source with high energy and density of electrons; the increase of electron production rate and density of plasma. The numerical simulations of lead ion production in the mixture with different light ions and different heavy and intermediate ions in the mixture with oxygen, are carried out to predict the principal ECR source possibilities for LHC applications. 18 refs., 23 refs

  6. Recoil ion spectroscopy with heavy ions

    International Nuclear Information System (INIS)

    Beyer, H.F.; Mann, R.

    1984-01-01

    This chapter examines the production of very high charge state ions in single ion-atom collisions. Topics considered include some aspects of highly ionized atoms, experimental approaches, the production of highly charged target ions (monoatomic targets, recoil energy distribution, molecular fragmentation, outer-shell rearrangement, lifetime measurements, a comparison of projectile-, target-, and plasma-ion stripping), and secondary collision experiments (selective electron capture, potential applications). The heavy-ion beams for the described experiments were provided by accelerators such as tandem Van de Graaff facility and the UNILAC

  7. Evaluation of technetium-99m/rhenium labelled nucleoside analogues as potential radiotracers in oncology[Dissertation 17173

    Energy Technology Data Exchange (ETDEWEB)

    Desbouis, D

    2007-07-01

    }M). This compound also exhibited a mixed inhibition of the hTK1 with K{sub ic} = 73 {+-} 20 {mu}M. When tested in vitro for cell uptake in transfected cancer cells this technetium thymidine complex revealed a low internalisation of 0.03 {+-} 0.01%ID/(mg/mL). Under the same conditions the [{sup 3}H]thymidine exhibited an uptake of 1.50 {+-} 0.02%lD/(mg/mL). In order to gain potency and selectivity for HSV1-TK, the corresponding 5'-carboxamide 5-ethyl-2', 5'-dideoxyuridine was synthesized. The synthesis of the ligand was performed in seven steps from 2'-deoxyuridine. This ligand was then successfully labelled with the fac-M(CO){sub 3}-core (M = {sup 99m}Tc, Re). The rhenium complex was found to be a selective competitive inhibitor of HSV1-TK (K{sub i} = 4.56 {+-} 0.11 {mu}M). Although the cellular uptake of the technetium 2'-deoxyurine complex (0.10 {+-} 0.01%ID/(mg/mL)) was better than its corresponding technetium thymidine complex, it is still very low compared to thymidine uptake. The second aspect of this work was to develop nucleoside derivatives labelled with technetium-99m/rhenium tricarbonyl core capable of acting as substrates for human cytosolic thymidine kinase (hTKl). hTKl is a target of choice to evaluate cell proliferation due to its overexpression in a variety of cancer cells. [{sup 18}F]Fluorothymidine [{sup 18}F]FLT), which acts as a hTKl substrate, has emerged as a very efficient PET tracer for the monitoring of cell proliferation. Our aim was to develop a SPET tracer with the same mode of action as [{sup 18}F]FLT. We prepared a set of technetium-99m/rhenium complexes of N3 thymidine derivatives with different overall charges (+1, 0 and -1) and variable spacer lengths. The complexes with different overall charges had the same spacer length between chelating system and thymidine moiety (two carbons spacer) while the complexes with different spacer lengths (2, 3, 5 and 10) were all neutral. These compounds were tested for their

  8. Ionization of selected elements of interest in the nuclear fuel cycle

    Energy Technology Data Exchange (ETDEWEB)

    Delmore, J. E.

    1978-07-01

    Three most common methods of ionizing the actinides using thermal ionization are discussed. The first and most commonly used technique involves evaporating the oxide from a side filament and ionizing it on a hot rhenium center filament. The second method, which is used almost as frequently as the first, involves loading the sample onto a rhenium single filament and reducing the sample. This method gives excellent sensitivity for small samples using a multiplier as the detector, but is less suitable for large samples and Faraday cup detectors. The first method is well suited for large samples on instruments with Faraday cup detectors. The third technique involves loading the sample onto a single tantalum filament, flashing to red heat in the air, and analyzing the oxide or dioxide ion beam. This technique gives reasonably stable ion beams for the lighter actinides and all of the lanthanides. It is not as sensitive as the other methods and is mentioned mainly for historical interest as it was widely used 25 years ago. The suitability of these methods for thorium, uranium, plutonium and americium, as well as for the lanthanides and other fission product elements are covered in detail. Besides these three methods, the resin bead technique and the silica gel technique are mentioned. The conclusion is that there is a great deal of work which needs to be carried out before a complete understanding of these ionization processes are understood.

  9. Surface negative ion production in ion sources

    International Nuclear Information System (INIS)

    Belchenko, Y.

    1993-01-01

    Negative ion sources and the mechanisms for negative ion production are reviewed. Several classes of sources with surface origin of negative ions are examined in detail: surface-plasma sources where ion production occurs on the electrode in contact with the plasma, and ''pure surface'' sources where ion production occurs due to conversion or desorption processes. Negative ion production by backscattering, impact desorption, and electron- and photo-stimulated desorption are discussed. The experimental efficiencies of intense surface negative ion production realized on electrodes contacted with hydrogen-cesium or pure hydrogen gas-discharge plasma are compared. Recent modifications of surface-plasma sources developed for accelerator and fusion applications are reviewed in detail

  10. Ion-ion collisions

    International Nuclear Information System (INIS)

    Salzborn, Erhard; Melchert, Frank

    2000-01-01

    Collisions between ions belong to the elementary processes occurring in all types of plasmas. In this article we give a short overview about collisions involving one-electron systems. For collisions involving multiply-charged ions we limit the discussion to one specific quasi-one-electron system. (author)

  11. Re4As6S3, a thio-spinel-related cluster system

    DEFF Research Database (Denmark)

    Besnard, Celine; Svensson, Christer; Ståhl, Kenny

    2003-01-01

    . The rhenium atoms form tetrahedral clusters linked via tetrahedral arsenic clusters to produce an NaCl-type arrangement. The oxidation state of rhenium is IV and the number of electrons shared by the rhenium atoms in the cluster is 12. The structure is based on an ordered defect thio-spinel A((1-x))B(2)X(4......) where the B-type atoms form tetrahedral clusters....

  12. Numerical simulation of ion temperature gradient driven modes in the presence of ion-ion collisions

    International Nuclear Information System (INIS)

    Xu, X.Q.

    1990-08-01

    Ion temperature gradient driven modes in the presence of ion-ion collisions in a toroidal geometry with trapped ions have been studied by using a 1 2/2 d linearized gyro-kinetic particle simulation code in the electrostatic limit. The purpose of the investigation is to try to understand the physics of flat density discharges, in order to test the marginal stability hypothesis. Results giving threshold conditions of L Ti /R 0 , an upper bound on k χ , and linear growth rates and mode frequencies over all wavelengths for the collisionless ion temperature gradient driven modes are obtained. The behavior of ion temperature gradient driven instabilities in the transition from slab to toroidal geometry, with trapped ions, is shown. A Monte Carlo scheme for the inclusion of ion-ion collisions, in which ions can undergo Coulomb collisional dynamical friction, velocity space diffusion and random walk of guiding centers, has been constructed. The effects of ion-ion collisions on the long wave length limit of the ion modes is discussed. 44 refs., 12 figs

  13. Phytoextraction of rhenium by lucerne (Medicago sativa) and erect milkvetch (Astragalus adsurgens) from alkaline soils amended with coal fly ash.

    Science.gov (United States)

    He, Honghua; Dong, Zhigang; Pang, Jiayin; Wu, Gao-Lin; Zheng, Jiyong; Zhang, Xingchang

    2018-07-15

    Coal fly ash (CFA) is an industrial waste generated in huge amounts worldwide, and the management of CFA has become an environmental concern. Recovery of valuable metals from CFA is one of the beneficial reuse options of CFA. Rhenium (Re) is one of the rarest metals in the Earth's crust and one of the most expensive metals of strategic significance in the world market. A CFA at the Jungar Thermal Power Plant, Inner Mongolia, China, contains more Re than two alkaline soils in the surrounding region. Pot experiments were undertaken to grow lucerne (Medicago sativa) and erect milkvetch (Astragalus adsurgens) in a loessial soil and an aeolian sandy soil amended with different rates (5%, 10%, 20%, and 40%) of CFA. The results show that plant growth was considerably enhanced and Re concentration in plants was significantly increased when CFA was applied to the alkaline soils at rates of ≤20%; while in some cases plant growth was also markedly enhanced by the 40% CFA treatment, which increased plant Re concentration the most of all treatments. Both lucerne and erect milkvetch showed potential for phytoextracting Re from CFA-amended alkaline soils. Using CFA for soil amendment not only offers a potential solution for the waste disposal problem of CFA, but the phytoextraction of Re by both lucerne and erect milkvetch may also bring an economic profit in the future. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Scanning ion microscopy with low energy lithium ions

    International Nuclear Information System (INIS)

    Twedt, Kevin A.; Chen, Lei; McClelland, Jabez J.

    2014-01-01

    Using an ion source based on photoionization of laser-cooled lithium atoms, we have developed a scanning ion microscope with probe sizes of a few tens of nanometers and beam energies from 500 eV to 5 keV. These beam energies are much lower than the typical operating energies of the helium ion microscope or gallium focused ion beam systems. We demonstrate how low energy can be advantageous in ion microscopy when detecting backscattered ions, due to a decreased interaction volume and the potential for surface sensitive composition analysis. As an example application that demonstrates these advantages, we non-destructively image the removal of a thin residual resist layer during plasma etching in a nano-imprint lithography process. - Highlights: • We use an ion source based on photoionization of laser-cooled lithium atoms. • The ion source makes possible a low energy (500 eV to 5 keV) scanning ion microscope. • Low energy is preferred for ion microscopy with backscattered ions. • We use the microscope to image a thin resist used in nano-imprint lithography

  15. Ion microtomography using ion time-of-flight

    International Nuclear Information System (INIS)

    Roberts, M.L.; Heikkinen, D.W.; Proctor, I.D.; Pontau, A.E.; Olona, G.T.; Felter, T.E.; Morse, D.H.; Hess, B.V.

    1992-01-01

    We have developed and are in the process of testing an ion time-of-flight (TOF) detector system for use in our ion microtomography measurements. Using TOF, ion energy is determined by measurement of the ion's flight time over a certain path length. For ion microtomography, the principle advantage of TOF analysis is that ion count rates of several hundred thousand counts per second can be achieved as compared to a limit of about ten thousand ions per second when using a solid-state silicon surface barrier detector and associated electronics. This greater than 10 fold increase in count rate correspondingly shortens sample analysis time or increases the amount of data that can be collected on a given sample. Details of the system and progress to date are described

  16. Ion implantation

    International Nuclear Information System (INIS)

    Dearnaley, Geoffrey

    1975-01-01

    First, ion implantation in semiconductors is discussed: ion penetration, annealing of damage, gettering, ion implanted semiconductor devices, equipement requirements for ion implantation. The importance of channeling for ion implantation is studied. Then, some applications of ion implantation in metals are presented: study of the corrosion of metals and alloys; influence or ion implantation on the surface-friction and wear properties of metals; hyperfine interactions in implanted metals

  17. Investigation into complexing in Re7-H3O+-SO42--H2O system

    International Nuclear Information System (INIS)

    Sinyakova, G.S.

    1979-01-01

    Using the methods of spectrophotometry and conductometry it is shown, that in the ReO 4 - -H 3 O + -SO 4 2- -H 2 O system interaction between rhenium (7) and sulfuric acid takes place in a wide concentration range. In low-acid solutions at pH 2.0-0.9 rhenium(7) complex with proton is formed at the ratio of 1:1 with lgK 1 =3.30+-0.02. In 1-10 mol. sulfuric acid observed is consecutive complexing at the rhenium(7) - sulfuric acid ratio in the complex of 1:1 and 1:2 respectively with lgK 2 =0.93+-0.13 and lgK 3 =0.34+-0.03. At the background of concentrated perchloric acid rhenium (7) and sodium sulfate form two complex compounds at rhenium (7) - sodium sulfate ratio of 1:1 and 1:2 with lgK 1 =1.86+-0.02 and lgK 2 =2.35+-0.03

  18. Ion Beam Extraction by Discrete Ion Focusing

    DEFF Research Database (Denmark)

    2010-01-01

    An apparatus (900) and methods are disclosed for ion beam extraction. In an implementation, the apparatus includes a plasma source (or plasma) (802) and an ion extractor (804). The plasma source is adapted to generate ions and the ion extractor is immersed in the plasma source to extract a fracti...

  19. Functional activity of the rats’ hepatocytes under cancerogenesis

    Directory of Open Access Journals (Sweden)

    V. V. Ivchuk

    2007-10-01

    Full Text Available Enzymatic activity in rat’s hepatocytes under carcinoma Geuren T8 development as well as after introduction of rhenium compounds and cis-platin were studied. It has been determined that the decrease of enzymatic activity contrary to the control animals has been observed under simultaneous injection of cis-platin and cluster rhenium compounds in a liposome form. That confirms possible hepatoprotective properties of the rhenium compounds.

  20. Ion creation, ion focusing, ion/molecule reactions, ion separation, and ion detection in the open air in a small plastic device.

    Science.gov (United States)

    Baird, Zane; Wei, Pu; Cooks, R Graham

    2015-02-07

    A method is presented in which ions are generated and manipulated in the ambient environment using polymeric electrodes produced with a consumer-grade 3D printer. The ability to focus, separate, react, and detect ions in the ambient environment is demonstrated and the data agree well with simulated ion behaviour.

  1. Rhenium-188 Lipiodol Therapy of Hepatocellular Carcinoma: Results of a multicentre-multinational study

    International Nuclear Information System (INIS)

    Padhy, A.K.; Bernal, P.; Buscombe, R.J.

    2007-01-01

    Full text: A multi-centre study was sponsored by the IAEA to assess the safety and efficacy of trans-arterial Rhenium-188 HDD Lipiodol in the treatment of inoperable Hepatocellular Carcinoma. The radioconjugate was prepared by using an HDD kit and Lipiodol. Over three years, 185 patients received at least one treatment. The dose administered was based on radiation absorbed dose to critical normal organs, calculated following a ''scout'' dose (approximately 4 mCi) of radioconjugate. The organs at greatest risk for radiation toxicity are the liver, the lung and the bone marrow. An Excel spreadsheet was used to determine maximum tolerated activity, defined as the amount of radioactivity calculated to deliver no more than 12 Gy to lungs, 30 Gy to liver, or 1.5 Gy to bone marrow. A single treatment was given to 134 patients, 42 patients received two doses, 8 received three and one patient received four treatments. The total injected activity including the scout dose during the first treatment ranged from 21 to 364 mCi (average 108 mCi). Patients were followed for at least l2 weeks after therapy. The clinical parameters evaluated included toxicity, response as determined objectively by contrast enhanced computed tomography, palliation of symptoms, overall survival, performance status (Karnofsky), and hepatic function (Child's classification). Liver function tests, serum alpha-fetoprotein (AFP) levels and complete blood counts were done at each follow-up visit. Side effects were minimal and usually presented as loss of appetite, right hypochondrial discomfort and low-grade fever. Liver function tests at 24 and 72 hours showed no significant changes and complete blood counts at 1 week, 4 weeks and 12 weeks showed no changes (no bone marrow suppression). Data on largest tumour diameter after therapy and/or tumour response as evaluated from CT scans are available for 88 patients. Complete disappearance of tumour was recorded in 3 (3%), partial response in 19 (22%), stable

  2. Study of ion exchange equilibrium and determination of heat of ion exchange by ion chromatography

    International Nuclear Information System (INIS)

    Liu Kailu; Yang Wenying

    1996-01-01

    Ion chromatography using pellicularia ion exchange resins and dilute solution can be devoted to the study of ion exchange thermodynamics and kinetics. Ion exchange equilibrium equation was obtained, and examined by the experiments. Based on ion exchange equilibrium, the influence of eluent concentration and resin capacity on adjusted retention volumes was examined. The effect of temperature on adjusted retention volumes was investigated and heats of ion exchange of seven anions were determined by ion chromatography. The interaction between anions and skeleton structure of resins were observed

  3. Polyatomic ions from a high current ion implanter driven by a liquid metal ion source

    Science.gov (United States)

    Pilz, W.; Laufer, P.; Tajmar, M.; Böttger, R.; Bischoff, L.

    2017-12-01

    High current liquid metal ion sources are well known and found their first application as field emission electric propulsion thrusters in space technology. The aim of this work is the adaption of such kind of sources in broad ion beam technology. Surface patterning based on self-organized nano-structures on, e.g., semiconductor materials formed by heavy mono- or polyatomic ion irradiation from liquid metal (alloy) ion sources (LMAISs) is a very promising technique. LMAISs are nearly the only type of sources delivering polyatomic ions from about half of the periodic table elements. To overcome the lack of only very small treated areas by applying a focused ion beam equipped with such sources, the technology taken from space propulsion systems was transferred into a large single-end ion implanter. The main component is an ion beam injector based on high current LMAISs combined with suited ion optics allocating ion currents in the μA range in a nearly parallel beam of a few mm in diameter. Different types of LMAIS (needle, porous emitter, and capillary) are presented and characterized. The ion beam injector design is specified as well as the implementation of this module into a 200 kV high current ion implanter operating at the HZDR Ion Beam Center. Finally, the obtained results of large area surface modification of Ge using polyatomic Bi2+ ions at room temperature from a GaBi capillary LMAIS will be presented and discussed.

  4. Experimental Evaluation of a Negative Ion Source for a Heavy Ion Fusion Negative Ion Driver

    International Nuclear Information System (INIS)

    Grisham, L.R.; Hahto, S.K.; Hahto, S.T.; Kwan, J.W.; Leung, K.N.

    2004-01-01

    Negative halogen ions have recently been proposed as a possible alternative to positive ions for heavy ion fusion drivers because electron accumulation would not be a problem in the accelerator, and if desired, the beams could be photo-detached to neutrals. To test the ability to make suitable quality beams, an experiment was conducted at Lawrence Berkeley National Laboratory using chlorine in an RF-driven ion source. Without introducing any cesium (which is required to enhance negative ion production in hydrogen ion sources) a negative chlorine current density of 45 mA/cm 2 was obtained under the same conditions that gave 57 45 mA/cm 2 of positive chlorine, suggesting the presence of nearly as many negative ions as positive ions in the plasma near the extraction plane. The negative ion spectrum was 99.5% atomic chlorine ions, with only 0.5% molecular chlorine, and essentially no impurities. Although this experiment did not incorporate the type of electron suppression technology that i s used in negative hydrogen beam extraction, the ratio of co-extracted electrons to Cl - was as low as 7 to 1, many times lower than the ratio of their mobilities, suggesting that few electrons are present in the near-extractor plasma. This, along with the near-equivalence of the positive and negative ion currents, suggests that the plasma in this region was mostly an ion-ion plasma. The negative chlorine current density was relatively insensitive to pressure, and scaled linearly with RF power. If this linear scaling continues to hold at higher RF powers, it should permit current densities of 100 45 mA/cm 2 , sufficient for present heavy ion fusion injector concepts. The effective ion temperatures of the positive and negative ions appeared to be similar and relatively low for a plasma source

  5. Laser-cooled atomic ions as probes of molecular ions

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Kenneth R.; Viteri, C. Ricardo; Clark, Craig R.; Goeders, James E.; Khanyile, Ncamiso B.; Vittorini, Grahame D. [Schools of Chemistry and Biochemistry, Computational Science and Engineering and Physics, Georgia Institute of Technology, Atlanta, GA 30332 (United States)

    2015-01-22

    Trapped laser-cooled atomic ions are a new tool for understanding cold molecular ions. The atomic ions not only sympathetically cool the molecular ions to millikelvin temperatures, but the bright atomic ion fluorescence can also serve as a detector of both molecular reactions and molecular spectra. We are working towards the detection of single molecular ion spectra by sympathetic heating spectroscopy. Sympathetic heating spectroscopy uses the coupled motion of two trapped ions to measure the spectra of one ion by observing changes in the fluorescence of the other ion. Sympathetic heating spectroscopy is a generalization of quantum logic spectroscopy, but does not require ions in the motional ground state or coherent control of the ion internal states. We have recently demonstrated this technique using two isotopes of Ca{sup +} [Phys. Rev. A, 81, 043428 (2010)]. Limits of the method and potential applications for molecular spectroscopy are discussed.

  6. Blood superoxiddismutase and catalase: enzymes activity under oxidative stress conditions

    OpenAIRE

    Каріна Леонідівна Шамелашвілі; Інга Володимирівна Леус; Тетяна Іванівна Сергієнко; Марина Вячеславівна Горіла; Наталія Іванівна Штеменко

    2015-01-01

    The activity of catalase and superoxide dismutase depends not only on the used compounds of rhenium, and also on their dimensional structure and form of applying. It is established that the cis- and trans-isomers of complex compounds of rhenium did countervailing effect on superoxide dismutase and catalase activities. Cis-isomers of Rhenium dycarboxylats agreed increased activity of superoxide dismutase and catalase. While under the action of trans-isomers, where increased activity of superox...

  7. Bimetallic Catalysts and Platinum Surfaces Studied by X-ray Absorption Spectroscopy and Scanning Tunnelling Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Roenning, Magnus

    2000-07-01

    Bimetallic catalyst systems used in Fischer-Tropsch synthesis (Co-Re/Al{sub 2}O{sub 3}) and in the naphtha reforming process (Pt-Re/Al{sub 2}O{sub 3}) have been studied in situ using X-ray absorption spectroscopy (EXAFS). Additionally, the adsorption of ethene on platinum single crystal surfaces has been investigated using scanning tunnelling microscopy. In situ EXAFS at the cobalt K absorption edge have been carried out at 450{sup o}C on the hydrogen reduction of a rhenium-promoted Co{sub 3}O{sub 4}/Al{sub 2}O{sub 3} catalyst. Reductions carried out using 100% hydrogen and 5% hydrogen in helium gave different results. Whereas the reduction using dilute hydrogen leads to bulk-like metallic cobalt particles (hcp or fcc), reaction with pure hydrogen yields a more dispersed system with smaller cobalt metal particles (< 40 A). The results are rationalised in terms of different degrees of reoxidation of cobalt by the higher and lower concentrations of water generated during the reduction of cobalt oxide by 100% and 5% hydrogen, respectively. Additionally, in both reduction protocols a small fraction (3 -4 wt%) of the cobalt content is randomly dispersed over the tetrahedral vacancies of the alumina support. This dispersion occurs during reduction and not calcination. The cobalt in these sites cannot be reduced at 450 {sup o}C. The local environments about the rhenium atoms in Co-Re/{gamma}-A1{sub 2}O{sub 3} catalyst after different reduction periods have been studied by X-ray absorption spectroscopy. A bimetallic catalyst containing 4.6 wt% cobalt and 2 wt% rhenium has been compared with a corresponding monometallic sample with 2 wt% rhenium on the same support. The rhenium L{sub III} EXAFS analysis shows that bimetallic particles are formed after reduction at 450{sup o}C with the average particle size being 10-15 A. Rhenium is shown to be reduced at a later stage than cobalt. The fraction of cobalt atoms entering the support obstructs the access to the support for the

  8. A novel ion imager for secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Matsumoto, Kazuya; Miyata, Kenji; Nakamura, Tsutomu

    1993-01-01

    This paper describes a new area detector for secondary ion mass spectrometry (SIMS) ion microscope, and its performance. The operational principle is based on detecting the change in potential of a floating photodiode caused by the ion-induced secondary-electron emission and the incoming ion itself. The experiments demonstrated that 10 1 -10 5 aluminum ions per pixel can be detected with good linear response. Moreover, relative ion sensitivities from hydrogen to lead were constant within a factor of 2. The performance of this area detector provides the potential for detection of kiloelectronvolt ion images with current ion microscopy

  9. Perspective on the Role of Negative Ions and Ion-Ion Plasmas in Heavy Ion Fusion Science, Magnetic Fusion Energy,and Related Fields

    International Nuclear Information System (INIS)

    Grisham, L.R.; Kwan, J.W.

    2008-01-01

    Some years ago it was suggested that halogen negative ions could offer a feasible alternative path to positive ions as a heavy ion fusion driver beam which would not suffer degradation due to electron accumulation in the accelerator and beam transport system, and which could be converted to a neutral beam by photodetachment near the chamber entrance if desired. Since then, experiments have demonstrated that negative halogen beams can be extracted and accelerated away from the gas plume near the source with a surviving current density close to what could be achieved with a positive ion of similar mass, and with comparable optical quality. In demonstrating the feasibility of halogen negative ions as heavy ion driver beams, ion - ion plasmas, an interesting and somewhat novel state of matter, were produced. These plasmas, produced near the extractor plane of the sources, appear, based upon many lines of experimental evidence, to consist of almost equal densities of positive and negative chlorine ions, with only a small component of free electrons. Serendipitously, the need to extract beams from this plasma for driver development provides a unique diagnostic tool to investigate the plasma, since each component - positive ions, negative ions, and electrons - can be extracted and measured separately. We discuss the relevance of these observations to understanding negative ion beam extraction from electronegative plasmas such as halogens, or the more familiar hydrogen of magnetic fusion ion sources. We suggest a concept which might improve negative hydrogen extraction by the addition of a halogen. The possibility and challenges of producing ion - ion plasmas with thin targets of halogens or, perhaps, salt, is briefly addressed.

  10. Perspective on the Role of Negative Ions and Ion-Ion Plasmas in Heavy Ion Fusion Science, Magnetic Fusion Energy, and Related Fields

    International Nuclear Information System (INIS)

    Grisham, L.R.; Kwan, J.W.

    2008-01-01

    Some years ago it was suggested that halogen negative ions (1)could offer a feasible alternative path to positive ions as a heavy ion fusion driver beam which would not suffer degradation due to electron accumulation in the accelerator and beam transport system, and which could be converted to a neutral beam by photodetachment near the chamber entrance if desired. Since then, experiments have demonstrated that negative halogen beams can be extracted and accelerated away from the gas plume near the source with a surviving current density close to what could be achieved with a positive ion of similar mass, and with comparable optical quality. In demonstrating the feasibility of halogen negative ions as heavy ion driver beams, ion-ion plasmas, an interesting and somewhat novel state of matter, were produced. These plasmas, produced near the extractor plane of the sources, appear, based upon many lines of experimental evidence, to consist of almost equal densities of positive and negative chlorine ions, with only a small component of free electrons. Serendipitously, the need to extract beams from this plasma for driver development provides a unique diagnostic tool to investigate the plasma, since each component--positive ions, negative ions, and electrons--can be extracted and measured separately. We discuss the relevance of these observations to understanding negative ion beam extraction from electronegative plasmas such as halogens, or the more familiar hydrogen of magnetic fusion ion sources. We suggest a concept which might improve negative hydrogen extraction by the addition of a halogen. The possibility and challenges of producing ion-ion plasmas with thin targets of halogens or, perhaps, salt, is briefly addressed

  11. Dissecting the Re-Os molybdenite geochronometer.

    Science.gov (United States)

    Barra, Fernando; Deditius, Artur; Reich, Martin; Kilburn, Matt R; Guagliardo, Paul; Roberts, Malcolm P

    2017-11-22

    Rhenium and osmium isotopes have been used for decades to date the formation of molybdenite (MoS 2 ), a common mineral in ore deposits and the world's main source of molybdenum and rhenium. Understanding the distribution of parent 187 Re and radiogenic daughter 187 Os isotopes in molybdenite is critical in interpreting isotopic measurements because it can compromise the accurate determination and interpretation of mineralization ages. In order to resolve the controls on the distribution of these elements, chemical and isotope mapping of MoS 2 grains from representative porphyry copper-molybdenum deposits were performed using electron microprobe and nano-scale secondary ion mass spectrometry. Our results show a heterogeneous distribution of 185,187 Re and 192 Os isotopes in MoS 2 , and that both 187 Re and 187 Os isotopes are not decoupled as previously thought. We conclude that Re and Os are structurally bound or present as nanoparticles in or next to molybdenite grains, recording a complex formation history and hindering the use of microbeam techniques for Re-Os molybdenite dating. Our study opens new avenues to explore the effects of isotope nuggeting in geochronometers.

  12. Design study of primary ion provider for relativistic heavy ion collider electron beam ion source.

    Science.gov (United States)

    Kondo, K; Kanesue, T; Tamura, J; Okamura, M

    2010-02-01

    Brookhaven National Laboratory has developed the new preinjector system, electron beam ion source (EBIS) for relativistic heavy ion collider (RHIC) and National Aeronautics and Space Administration Space Radiation Laboratory. Design of primary ion provider is an essential problem since it is required to supply beams with different ion species to multiple users simultaneously. The laser ion source with a defocused laser can provide a low charge state and low emittance ion beam, and is a candidate for the primary ion source for RHIC-EBIS. We show a suitable design with appropriate drift length and solenoid, which helps to keep sufficient total charge number with longer pulse length. The whole design of primary ion source, as well as optics arrangement, solid targets configuration and heating about target, is presented.

  13. Ion-Beam-Excited Electrostatic Ion Cyclotron Waves

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1976-01-01

    Self-excited electrostatic ion cyclotron waves were observed in an ion-beam-plasma system produced in a DP-operated Q-machine. The frequency of the waves showed the theoretically predicted variation with the magnetic field.......Self-excited electrostatic ion cyclotron waves were observed in an ion-beam-plasma system produced in a DP-operated Q-machine. The frequency of the waves showed the theoretically predicted variation with the magnetic field....

  14. Ion mobilities and ion-atom interaction potentials

    International Nuclear Information System (INIS)

    Gatland, I.R.

    1982-01-01

    The techniques for measuring the mobilities of ions in gases, relating interaction potentials to mobilities, and determining potentials from experimental mobilities are reviewed. Applications are presented for positive alkali ions and negative halogen ions in inert gases. (Auth.)

  15. Low-altitude ion heating with downflowing and upflowing ions

    Science.gov (United States)

    Shen, Y.; Knudsen, D. J.; Burchill, J. K.; Howarth, A. D.; Yau, A. W.; James, G.; Miles, D.; Cogger, L. L.; Perry, G. W.

    2017-12-01

    Mechanisms that energize ions at the initial stage of ion upflow are still not well understood. We statistically investigate ionospheric ion energization and field-aligned motion at very low altitudes (330-730 km) using simultaneous plasma, magnetic field, wave electric field and optical data from the e-POP satellite. The high-time-resolution (10 ms) dataset enables us to study the micro-structures of ion heating and field-aligned ion motion. The ion temperature and field-aligned bulk flow velocity are derived from 2-D ion distribution functions measured by the SEI instrument. From March 2015 to March 2016, we've found 17 orbits (in total 24 ion heating periods) with clear ion heating signatures passing across the dayside cleft or the nightside auroral regions. Most of these events have consistent ion heating and flow velocity characteristics observed from both the SEI and IRM instruments. The perpendicular ion temperature goes up to 4.5 eV within a 2 km-wide region in some cases, in which the Radio Receiver Instrument (RRI) sees broadband extremely low frequency (BBELF) waves, demonstrating significant wave-ion heating down to as low as 350 km. The e-POP Fast Auroral Imager (FAI) and Magnetic Field (MGF) instruments show that many events are associated with active aurora and are within downward current regions. Contrary to what would be expected from mirror-force acceleration of heated ions, the majority of these heating events (17 out of 24) are associated with the core ion downflow rather than upflow. These statistical results provide us with new sights into ion heating and field-aligned flow processes at very low altitudes.

  16. Design and simulation of ion optics for ion sources for production of singly charged ions

    Science.gov (United States)

    Zelenak, A.; Bogomolov, S. L.

    2004-05-01

    During the last 2 years different types of the singly charged ion sources were developed for FLNR (JINR) new projects such as Dubna radioactive ion beams, (Phase I and Phase II), the production of the tritium ion beam and the MASHA mass separator. The ion optics simulations for 2.45 GHz electron cyclotron resonance source, rf source, and the plasma ion source were performed. In this article the design and simulation results of the optics of new ion sources are presented. The results of simulation are compared with measurements obtained during the experiments.

  17. Design and simulation of ion optics for ion sources for production of singly charged ions

    International Nuclear Information System (INIS)

    Zelenak, A.; Bogomolov, S.L.

    2004-01-01

    During the last 2 years different types of the singly charged ion sources were developed for FLNR (JINR) new projects such as Dubna radioactive ion beams, (Phase I and Phase II), the production of the tritium ion beam and the MASHA mass separator. The ion optics simulations for 2.45 GHz electron cyclotron resonance source, rf source, and the plasma ion source were performed. In this article the design and simulation results of the optics of new ion sources are presented. The results of simulation are compared with measurements obtained during the experiments

  18. Crater formation by single ions, cluster ions and ion "showers"

    CERN Document Server

    Djurabekova, Flyura; Timko, Helga; Nordlund, Kai; Calatroni, Sergio; Taborelli, Mauro; Wuensch, Walter

    2011-01-01

    The various craters formed by giant objects, macroscopic collisions and nanoscale impacts exhibit an intriguing resemblance in shapes. At the same time, the arc plasma built up in the presence of sufficiently high electric fields at close look causes very similar damage on the surfaces. Although the plasma–wall interaction is far from a single heavy ion impact over dense metal surfaces or the one of a cluster ion, the craters seen on metal surfaces after a plasma discharge make it possible to link this event to the known mechanisms of the crater formations. During the plasma discharge in a high electric field the surface is subject to high fluxes (~1025 cm-2s-1) of ions with roughly equal energies typically of the order of a few keV. To simulate such a process it is possible to use a cloud of ions of the same energy. In the present work we follow the effect of such a flux of ions impinging the surface in the ‘‘shower’’ manner, to find the transition between the different mechanisms of crater formati...

  19. Single-ion conducting diblock terpolymers for lithium-ion batteries

    Science.gov (United States)

    Morris, Melody; Epps, Thomas H., III

    Block polymer (BP) electrolytes provide an attractive route to overcome the competing constraints of high conductivity and mechanical/thermal stability in lithium-ion batteries through nanoscale self-assembly. For example, macromolecules can be engineered such that one domain conducts lithium ions and the other prevents lithium dendrite formation. Herein, we report on the behavior of a single-ion conducting BP electrolyte that was designed to facilitate the transport of lithium ions. These polymers differ from traditional salt-doped BP electrolytes, which require the addition of a lithium salt to bestow conductivity and typically suffer from substantial counterion motion that reduces efficiency. New single-ion BPs were synthesized, and the nanoscale morphologies were determined using small angle X-ray scattering and transmission electron microscopy. Electrolyte performance was measured using AC impedance spectroscopy and DC polarization, and the results were correlated to nanoscale morphology and ion content. Enhanced physical understanding of single-ion BPs was gained by connecting the ion mobility to the chemistry, chain structure, and ion content of the single-ion BP. These studies can be applied to other charged-neutral block polymers to elucidate the effects of ion content on self-assembly and macroscopic properties.

  20. Investigation into complexing in Re/sup 7/-H/sub 3/O/sup +/-SO/sub 4//sup 2 -/-H/sub 2/O system

    Energy Technology Data Exchange (ETDEWEB)

    Sinyakova, G S [AN Latvijskoj SSR, Riga. Inst. Neorganicheskoj Khimii

    1979-10-01

    Using the methods of spectrophotometry and conductometry it is shown, that in the ReO/sub 4//sup -/-H/sub 3/O/sup +/-SO/sub 4//sup 2 -/-H/sub 2/O system interaction between rhenium (7) and sulfuric acid takes place in a wide concentration range. In low-acid solutions at pH 2.0-0.9 rhenium(7) complex with proton is formed at the ratio of 1:1 with lgK/sub 1/=3.30+-0.02. In 1-10 mol. sulfuric acid observed is consecutive complexing at the rhenium(7) - sulfuric acid ratio in the complex of 1:1 and 1:2 respectively with lgK/sub 2/=0.93+-0.13 and lgK/sub 3/=0.34+-0.03. At the background of concentrated perchloric acid rhenium (7) and sodium sulfate form two complex compounds at rhenium (7) - sodium sulfate ratio of 1:1 and 1:2 with lgK/sub 1/=1.86+-0.02 and lgK/sub 2/=2.35+-0.03.

  1. Materials and fabrication processes for operation in hot hydrogen

    International Nuclear Information System (INIS)

    Tuffias, R.H.; Duffy, A.J.; Arrieta, V.M.; Abrams, W.M.; Benander, R.E.

    1997-01-01

    Operation in hot (2500 endash 3000 K) hydrogen severely limits the choice of structural materials. Rhenium is nonreactive with and has low permeability to hydrogen, and has sufficient strength up to 2800 K. Carbon, in the form of graphite or carbon composites, has excellent high temperature strength but reacts with hydrogen to form methane at a rapid rate above 2000 K. The carbides of zirconium, niobium, hafnium, and tantalum are nonreactive with and have low permeability to hydrogen, but they can be reliably fabricated only in the form of coatings. In order to demonstrate the Integrated Solar Upper Stage (ISUS) solar-thermal propulsion concept, rhenium and rhenium-coated graphite were chosen as the structural materials for the receiver-absorber-converter (RAC) component of the ISUS system. Several methods were investigated for fabricating the rhenium parts and coatings, with chemical vapor deposition (CVD) and Ultramet chosen as the most likely process and company for success. The CVD or rhenium and other refractory materials were thus applied to the ISUS program for fabrication of the RAC subsystem. copyright 1997 American Institute of Physics

  2. Enhanced ion acoustic fluctuations and ion outflows

    Directory of Open Access Journals (Sweden)

    F. R. E. Forme

    1999-02-01

    Full Text Available A number of observations showing enhanced ion acoustic echoes observed by means of incoherent scatter radars have been reported in the literature. The received power is extremely enhanced by up to 1 or 2 orders of magnitude above usual values, and it is mostly contained in one of the two ion acoustic lines. This spectral asymmetry and the intensity of the received signal cannot be resolved by the standard analysis procedure and often causes its failure. As a result, and in spite of a very clear spectral signature, the analysis is unable to fit the plasma parameters inside the regions of ion acoustic turbulence. We present European Incoherent Scatter radar (EISCAT observations of large ion outflows associated with the simultaneous occurrence of enhanced ion acoustic echoes. The ion fluxes can reach 1014 m-2 s-1 at 800 km altitude. From the very clear spectral signatures of these echoes, a method is presented to extract estimates of the electron temperature and the ion drift within the turbulent regions. It is shown that the electron gas is strongly heated up to 11 000 K. Also electron temperature gradients of about 0.02 K/m exist. Finally, the estimates of the electron temperature and of the ion drift are used to study the possible implications for the plasma transport inside turbulent regions. It is shown that strong electron temperature gradients cause enhancement of the ambipolar electric field and can account for the observed ion outflows.Key words. Ionosphere (auroral ionosphere; ionosphere · magnetosphere interactions; plasma waves and instabilities.

  3. Ion sources for heavy ion fusion

    International Nuclear Information System (INIS)

    Yu, S.S.; Eylon, S.; Chupp, W.

    1995-09-01

    The development of ion sources for heavy ion fusion will be reported with particular emphasis on a recently built 2 MV injector. The new injector is based on an electrostatic quadrupole configuration, and has produced pulsed K + ions of 950 mA peak from a 6.7 inch curved alumino silicate source. The ion beam has reached 2.3 MV with an energy flatness of ±0.2% over 1 micros. The measured normalized edge emittance of less than 1 π mm-mr is close to the source temperature limit. The design, construction, performance, and comparisons with three-dimensional particle-in-cell simulations will be described

  4. Ion-ion interaction and energy transfer of 4+ transuranium ions in cerium tetrafluoride

    International Nuclear Information System (INIS)

    Liu, G.K.; Beitz, J.V.

    1990-01-01

    Dynamics of excited 5f electron states of the transuranium ions Cm 4+ and Bk 4+ in CeF 4 are compared. Based on time- and wavelength-resolved laser-induced fluorescence, excitation energy transfer processes have been probed. Depending on concentration and electronic energy level structure of the studied 4+ transuranium ion, the dominant energy transfer mechanisms were identified as cross relaxation, exciton-exciton annihilation, and trapping. Energy transfer rates derived from the fitting of the observed fluorescence decays to theoretical models, based on electric multipolar ion-ion interactions, are contrasted with prior studies of 4f states of 3+ lanthanide and 3d states of transition metal ions. 16 refs., 1 tab

  5. Hydrocarbon conversion with an attenuated superactive multimetallic catalytic composite

    International Nuclear Information System (INIS)

    Antos, G.J.

    1981-01-01

    Hydrocarbons are converted by contacting them at hydrocarbon conversion conditions with a novel attenuated superactive multimetallic catalytic composite comprising a combination of a catalytically effective amount of a pyrolyzed rhenium carbonyl component with a porous carrier material containing a uniform dispersion of catalytically effective amounts of a platinum group component, which is maintained in the elemental metallic state during the incorporation and pyrolysis of the rhenium carbonyl component, and of an iron component. In a highly preferred embodiment, this novel catalytic composite also contains a catalytically effective amount of a halogen component. The platinum group component, pyrolyzed rhenium carbonyl component, iron component and optional halogen component are preferably present in the multimetallic catalytic composite in amounts, calculated on an elemental basis, corresponding to about 0.01 to about 2 wt. % platinum group metal, about 0.01 to about 5 wt. % rhenium, about 0.005 to about 4 wt. % iron and about 0.1 to about 5 wt. % halogen. A key feature associated with the preparation of the subject catalytic composite is reaction of a rhenium carbonyl complex with a porous carrier material containing a uniform dispersion of an iron component and of a platinum group component maintained in the elemental state, whereby the interaction of the rhenium moiety with the platinum group moiety is maximized due to the platinophilic (i.e., platinum-seeking) propensities of the carbon monoxide ligands associated with the rhenium reagent. A specific example of the type of hydrocarbon conversion process disclosed herein is a process for the catalytic reforming of a low octane gasoline fraction wherein the gasoline fraction and a hydrogen stream are contacted with the attenuated superactive multimetallic catalytic composite at reforming conditions

  6. Ion beam monitoring

    International Nuclear Information System (INIS)

    McKinney, C.R.

    1980-01-01

    An ion beam analyzer is specified, having an ion source for generating ions of a sample to be analyzed, means for extracting the sample ions, means for focusing the sample ions into a beam, separation means positioned along the ion beam for selectively deflecting species of ions, and means for detecting the selected species of ions. According to the specification, the analyzer further comprises (a) means for disabling at least a portion of the separation means, such that the ion beam from the source remains undeflected; (b) means located along the path of the undeflected ion beam for sensing the sample ions; and (c) enabling means responsive to the sensing means for automatically re-enabling the separation means when the sample ions reach a predetermined intensity level. (author)

  7. Ion acoustic solitons/double layers in two-ion plasma revisited

    International Nuclear Information System (INIS)

    Lakhina, G. S.; Singh, S. V.; Kakad, A. P.

    2014-01-01

    Ion acoustic solitons and double layers are studied in a collisionless plasma consisting of cold heavier ion species, a warm lighter ion species, and hot electrons having Boltzmann distributions by Sagdeev pseudo-potential technique. In contrast to the previous results, no double layers and super-solitons are found when both the heavy and lighter ion species are treated as cold. Only the positive potential solitons are found in this case. When the thermal effects of the lighter ion species are included, in addition to the usual ion-acoustic solitons occurring at M > 1 (where the Mach number, M, is defined as the ratio of the speed of the solitary wave and the ion-acoustic speed considering temperature of hot electrons and mass of the heavier ion species), slow ion-acoustic solitons/double layers are found to occur at low Mach number (M < 1). The slow ion-acoustic mode is actually a new ion-ion hybrid acoustic mode which disappears when the normalized number density of lighter ion species tends to 1 (i.e., no heavier species). An interesting property of the new slow ion-acoustic mode is that at low number density of the lighter ion species, only negative potential solitons/double layers are found whereas for increasing densities there is a transition first to positive solitons/double layers, and then only positive solitons. The model can be easily applicable to the dusty plasmas having positively charged dust grains by replacing the heavier ion species by the dust mass and doing a simple normalization to take account of the dust charge

  8. Blood superoxiddismutase and catalase: enzymes activity under oxidative stress conditions

    Directory of Open Access Journals (Sweden)

    Каріна Леонідівна Шамелашвілі

    2015-05-01

    Full Text Available The activity of catalase and superoxide dismutase depends not only on the used compounds of rhenium, and also on their dimensional structure and form of applying. It is established that the cis- and trans-isomers of complex compounds of rhenium did countervailing effect on superoxide dismutase and catalase activities. Cis-isomers of Rhenium dycarboxylats agreed increased activity of superoxide dismutase and catalase. While under the action of trans-isomers, where increased activity of superoxide dismutase, catalase activity decreased

  9. Negative ion sources

    International Nuclear Information System (INIS)

    Ishikawa, Junzo; Takagi, Toshinori

    1983-01-01

    Negative ion sources have been originally developed at the request of tandem electrostatic accelerators, and hundreds of nA to several μA negative ion current has been obtained so far for various elements. Recently, the development of large current hydrogen negative ion sources has been demanded from the standpoint of the heating by neutral particle beam injection in nuclear fusion reactors. On the other hand, the physical properties of negative ions are interesting in the thin film formation using ions. Anyway, it is the present status that the mechanism of negative ion action has not been so fully investigated as positive ions because the history of negative ion sources is short. In this report, the many mechanisms about the generation of negative ions proposed so far are described about negative ion generating mechanism, negative ion source plasma, and negative ion generation on metal surfaces. As a result, negative ion sources are roughly divided into two schemes, plasma extraction and secondary ion extraction, and the former is further classified into the PIG ion source and its variation and Duoplasmatron and its variation; while the latter into reflecting and sputtering types. In the second half of the report, the practical negative ion sources of each scheme are described. If the mechanism of negative ion generation will be investigated more in detail and the development will be continued under the unified know-how as negative ion sources in future, the development of negative ion sources with which large current can be obtained for any element is expected. (Wakatsuki, Y.)

  10. Experiments on Ion-Ion Plasmas From Discharges

    Science.gov (United States)

    Leonhardt, Darrin; Walton, Scott; Blackwell, David; Murphy, Donald; Fernsler, Richard; Meger, Robert

    2001-10-01

    Use of both positive and negative ions in plasma processing of materials has been shown to be advantageous[1] in terms of better feature evolution and control. In this presentation, experimental results are given to complement recent theoretical work[2] at NRL on the formation and decay of pulsed ion-ion plasmas in electron beam generated discharges. Temporally resolved Langmuir probe and mass spectrometry are used to investigate electron beam generated discharges during the beam on (active) and off (afterglow) phases in a variety of gas mixtures. Because electron-beam generated discharges inherently[3] have low electron temperatures (<0.5eV in molecular gases), negative ion characteristics are seen in the active as well as afterglow phases since electron detachment increases with low electron temperatures. Analysis of temporally resolved plasma characteristics deduced from these measurements will be presented for pure O_2, N2 and Ar and their mixtures with SF_6. Oxygen discharges show no noticeable negative ion contribution during the active or afterglow phase, presumably due to the higher energy electron attachment threshold, which is well above any electron temperature. In contrast, SF6 discharges demonstrate ion-ion plasma characteristics in the active glow and are completely ion-ion in the afterglow. Comparison between these discharges with published cross sections and production mechanisms will also be presented. [1] T.H. Ahn, K. Nakamura & H. Sugai, Plasma Sources Sci. Technol., 5, 139 (1996); T. Shibyama, H. Shindo & Y. Horiike, Plasma Sources Sci. Technol., 5, 254 (1996). [2] See presentation by R. F. Fernsler, at this conference. [3] D. Leonhardt, et al., 53rd Annual GEC, Houston, TX.

  11. Detection of gold cluster ions by ion-to-ion conversion using a CsI-converter

    International Nuclear Information System (INIS)

    Nguyen, V.-T.; Novilkov, A.C.; Obnorskii, V.V.

    1997-01-01

    Gold cluster ions in the m/z range of 10 4 -2 x 10 6 u were produced by bombarding a thin film of gold with 252 Cf-fission fragments. The gold covering a C-Al substrate formed islets having a mean diameter of 44 A. Their size- and mass-distribution was determined by means of electron microscopy. The main task was to measure the m/z distribution of the cluster ions ejected from the sample surface. For this purpose we built a time-of-flight (TOF) mass spectrometer, which could be used as a linear TOF instrument or, alternatively, as a tandem-TOF instrument being equipped with an ion-to-ion converter. Combining the results obtained in both modes, it turned out that the linear TOF instrument equipped with micro-channel plates had a mean detection efficiency for 20 keV cluster ions of about 40%. In the tandem mode, the cluster ions hit a CsI converter with energies of 40z keV (z = charge state), from where secondary ions - mainly Cs + and (CsI) n Cs + cluster ions - were ejected. These ions were used to measure the TOF spectrum of the gold cluster ions. The detection efficiency of the cluster ions was found to vary in the available mass range from 99.7% to 96.5%. The complete mass distribution between 4 x 10 4 and 4 x 10 6 u was determined and compared with the corresponding mass distribution of the gold islets covering the substrate. (orig.)

  12. Highly Stripped Ion Sources for MeV Ion Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Hershcovitch, Ady

    2009-06-30

    Original technical objectives of CRADA number PVI C-03-09 between BNL and Poole Ventura, Inc. (PVI) were to develop an intense, high charge state, ion source for MeV ion implanters. Present day high-energy ion implanters utilize low charge state (usually single charge) ion sources in combination with rf accelerators. Usually, a MV LINAC is used for acceleration of a few rnA. It is desirable to have instead an intense, high charge state ion source on a relatively low energy platform (de acceleration) to generate high-energy ion beams for implantation. This de acceleration of ions will be far more efficient (in energy utilization). The resultant implanter will be smaller in size. It will generate higher quality ion beams (with lower emittance) for fabrication of superior semiconductor products. In addition to energy and cost savings, the implanter will operate at a lower level of health risks associated with ion implantation. An additional aim of the project was to producing a product that can lead to long­ term job creation in Russia and/or in the US. R&D was conducted in two Russian Centers (one in Tomsk and Seversk, the other in Moscow) under the guidance ofPVI personnel and the BNL PI. Multiple approaches were pursued, developed, and tested at various locations with the best candidate for commercialization delivered and tested at on an implanter at the PVI client Axcelis. Technical developments were exciting: record output currents of high charge state phosphorus and antimony were achieved; a Calutron-Bemas ion source with a 70% output of boron ion current (compared to 25% in present state-of-the-art). Record steady state output currents of higher charge state phosphorous and antimony and P ions: P{sup 2+} (8.6 pmA), P{sup 3+} (1.9 pmA), and P{sup 4+} (0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+} Sb {sup 4 +}, Sb{sup 5+}, and Sb{sup 6+} respectively. Ultimate commercialization goals did not succeed (even though a number of the products like high

  13. Development of focused ion beam systems with various ion species

    International Nuclear Information System (INIS)

    Ji Qing; Leung, K.-N.; King, Tsu-Jae; Jiang Ximan; Appleton, Bill R.

    2005-01-01

    Conventional focused ion beam systems employ a liquid-metal ion source (LMIS) to generate high-brightness beams, such as Ga + beams. Recently there has been an increased need for focused ion beams in areas like biological studies, advanced magnetic-film manufacturing and secondary-ion mass spectroscopy (SIMS). In this article, status of development on focused ion beam systems with ion species such as O 2 + , P + , and B + will be reviewed. Compact columns for forming focused ion beams from low energy (∼3keV), to intermediate energy (∼35keV) are discussed. By using focused ion beams, a SOI MOSFET is fabricated entirely without any masks or resist

  14. Ion colliders

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, W.

    2011-12-01

    Ion colliders are research tools for high-energy nuclear physics, and are used to test the theory of Quantum Chromo Dynamics (QCD). The collisions of fully stripped high-energy ions create matter of a temperature and density that existed only microseconds after the Big Bang. Ion colliders can reach higher densities and temperatures than fixed target experiments although at a much lower luminosity. The first ion collider was the CERN Intersecting Storage Ring (ISR), which collided light ions [77Asb1, 81Bou1]. The BNL Relativistic Heavy Ion Collider (RHIC) is in operation since 2000 and has collided a number of species at numerous energies. The CERN Large Hadron Collider (LHC) started the heavy ion program in 2010. Table 1 shows all previous and the currently planned running modes for ISR, RHIC, and LHC. All three machines also collide protons, which are spin-polarized in RHIC. Ion colliders differ from proton or antiproton colliders in a number of ways: the preparation of the ions in the source and the pre-injector chain is limited by other effects than for protons; frequent changes in the collision energy and particle species, including asymmetric species, are typical; and the interaction of ions with each other and accelerator components is different from protons, which has implications for collision products, collimation, the beam dump, and intercepting instrumentation devices such a profile monitors. In the preparation for the collider use the charge state Z of the ions is successively increased to minimize the effects of space charge, intrabeam scattering (IBS), charge change effects (electron capture and stripping), and ion-impact desorption after beam loss. Low charge states reduce space charge, intrabeam scattering, and electron capture effects. High charge states reduce electron stripping, and make bending and acceleration more effective. Electron stripping at higher energies is generally more efficient. Table 2 shows the charge states and energies in the

  15. Ion colliders

    International Nuclear Information System (INIS)

    Fischer, W.

    2010-01-01

    Ion colliders are research tools for high-energy nuclear physics, and are used to test the theory of Quantum Chromo Dynamics (QCD). The collisions of fully stripped high-energy ions create matter of a temperature and density that existed only microseconds after the Big Bang. Ion colliders can reach higher densities and temperatures than fixed target experiments although at a much lower luminosity. The first ion collider was the CERN Intersecting Storage Ring (ISR), which collided light ions (77Asb1, 81Bou1). The BNL Relativistic Heavy Ion Collider (RHIC) is in operation since 2000 and has collided a number of species at numerous energies. The CERN Large Hadron Collider (LHC) started the heavy ion program in 2010. Table 1 shows all previous and the currently planned running modes for ISR, RHIC, and LHC. All three machines also collide protons, which are spin-polarized in RHIC. Ion colliders differ from proton or antiproton colliders in a number of ways: the preparation of the ions in the source and the pre-injector chain is limited by other effects than for protons; frequent changes in the collision energy and particle species, including asymmetric species, are typical; and the interaction of ions with each other and accelerator components is different from protons, which has implications for collision products, collimation, the beam dump, and intercepting instrumentation devices such a profile monitors. In the preparation for the collider use the charge state Z of the ions is successively increased to minimize the effects of space charge, intrabeam scattering (IBS), charge change effects (electron capture and stripping), and ion-impact desorption after beam loss. Low charge states reduce space charge, intrabeam scattering, and electron capture effects. High charge states reduce electron stripping, and make bending and acceleration more effective. Electron stripping at higher energies is generally more efficient. Table 2 shows the charge states and energies in the

  16. Ion Colliders

    CERN Document Server

    Fischer, W

    2014-01-01

    High-energy ion colliders are large research tools in nuclear physics to study the Quark-Gluon-Plasma (QGP). The range of collision energy and high luminosity are important design and operational considerations. The experiments also expect flexibility with frequent changes in the collision energy, detector fields, and ion species. Ion species range from protons, including polarized protons in RHIC, to heavy nuclei like gold, lead and uranium. Asymmetric collision combinations (e.g. protons against heavy ions) are also essential. For the creation, acceleration, and storage of bright intense ion beams, limits are set by space charge, charge change, and intrabeam scattering effects, as well as beam losses due to a variety of other phenomena. Currently, there are two operating ion colliders, the Relativistic Heavy Ion Collider (RHIC) at BNL, and the Large Hadron Collider (LHC) at CERN.

  17. Production of highly charged ion beams from ECR ion sources

    International Nuclear Information System (INIS)

    Xie, Z.Q.

    1997-09-01

    Electron Cyclotron Resonance (ECR) ion source development has progressed with multiple-frequency plasma heating, higher mirror magnetic fields and better technique to provide extra cold electrons. Such techniques greatly enhance the production of highly charged ions from ECR ion sources. So far at cw mode operation, up to 300 eμA of O 7+ and 1.15 emA of O 6+ , more than 100 eμA of intermediate heavy ions for charge states up to Ar 13+ , Ca 13+ , Fe 13+ , Co 14+ and Kr 18+ , and tens of eμA of heavy ions with charge states to Kr 26+ , Xe 28+ , Au 35+ , Bi 34+ and U 34+ have been produced from ECR ion sources. At an intensity of at least 1 eμA, the maximum charge state available for the heavy ions are Xe 36+ , Au 46+ , Bi 47+ and U 48+ . An order of magnitude enhancement for fully stripped argon ions (I ≥ 60 enA) also has been achieved. This article will review the ECR ion source progress and discuss key requirement for ECR ion sources to produce the highly charged ion beams

  18. Recoil ions

    International Nuclear Information System (INIS)

    Cocke, C.L.; Olson, R.E.

    1991-01-01

    The collision of a fast moving heavy ion with a neutral atomic target can produce very highly charged but slowly moving target ions. This article reviews experimental and theoretical work on the production and use of recoil ions beyond the second ionization state by beams with specific energies above 0.5 MeV/amu. A brief historical survey is followed by a discussion of theoretical approaches to the problem of the removal of many electrons from a neutral target by a rapid, multiply charged projectile. A discussion of experimental techniques and results for total and differential cross sections for multiple ionization of atomic and molecular targets is given. Measurements of recoil energy are discussed. The uses of recoil ions for in situ spectroscopy of multiply charged ions, for external beams of slow, highly charged ions and in ion traps are reviewed. Some possible future opportunities are discussed. (orig.)

  19. Advanced Materials and Fabrication Techniques for the Orion Attitude Control Motor

    Science.gov (United States)

    Gorti, Sridhar; Holmes, Richard; O'Dell, John; McKechnie, Timothy; Shchetkovskiy, Anatoliy

    2013-01-01

    Rhenium, with its high melting temperature, excellent elevated temperature properties, and lack of a ductile-to-brittle transition temperature (DBTT), is ideally suited for the hot gas components of the ACM (Attitude Control Motor), and other high-temperature applications. However, the high cost of rhenium makes fabricating these components using conventional fabrication techniques prohibitive. Therefore, near-net-shape forming techniques were investigated for producing cost-effective rhenium and rhenium alloy components for the ACM and other propulsion applications. During this investigation, electrochemical forming (EL-Form ) techniques were evaluated for producing the hot gas components. The investigation focused on demonstrating that EL-Form processing techniques could be used to produce the ACM flow distributor. Once the EL-Form processing techniques were established, a representative rhenium flow distributor was fabricated, and samples were harvested for material properties testing at both room and elevated temperatures. As a lower cost and lighter weight alternative to an all-rhenium component, rhenium- coated graphite and carbon-carbon were also evaluated. The rhenium-coated components were thermal-cycle tested to verify that they could withstand the expected thermal loads during service. High-temperature electroforming is based on electrochemical deposition of compact layers of metals onto a mandrel of the desired shape. Mandrels used for electro-deposition of near-net shaped parts are generally fabricated from high-density graphite. The graphite mandrel is easily machined and does not react with the molten electrolyte. For near-net shape components, the inner surface of the electroformed part replicates the polished graphite mandrel. During processing, the mandrel itself becomes the cathode, and scrap or refined refractory metal is the anode. Refractory metal atoms from the anode material are ionized in the molten electrolytic solution, and are deposited

  20. Ion Elevators and Escalators in Multilevel Structures for Lossless Ion Manipulations

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Yehia M.; Hamid, Ahmed M.; Cox, Jonathan T.; Garimella, Venkata BS; Smith, Richard D.

    2017-01-19

    We describe two approaches based upon ion ‘elevator’ and ‘escalator’ components that allow moving ions to different levels in structures for lossless ion manipulations (SLIM). Guided by ion motion simulations we designed elevator and escalator components providing essentially lossless transmission in multi-level designs based upon ion current measurements. The ion elevator design allowed ions to efficiently bridge a 4 mm gap between levels. The component was integrated in a SLIM and coupled to a QTOF mass spectrometer using an ion funnel interface to evaluate the m/z range transmitted as compared to transmission within a level (e.g. in a linear section). Mass spectra for singly-charged ions of m/z 600-2700 produced similar mass spectra for both elevator and straight (linear motion) components. In the ion escalator design, traveling waves (TW) were utilized to transport ions efficiently between two SLIM levels. Ion current measurements and ion mobility (IM) spectrometry analysis illustrated that ions can be transported between TW-SLIM levels with no significant loss of either ions or IM resolution. These developments provide a path for the development of multilevel designs providing e.g. much longer IM path lengths, more compact designs, and the implementation of much more complex SLIM devices in which e.g. different levels may operate at different temperatures or with different gases.

  1. Ion Elevators and Escalators in Multilevel Structures for Lossless Ion Manipulations.

    Science.gov (United States)

    Ibrahim, Yehia M; Hamid, Ahmed M; Cox, Jonathan T; Garimella, Sandilya V B; Smith, Richard D

    2017-02-07

    We describe two approaches based upon ion "elevator" and "escalator" components that allow moving ions to different levels in structures for lossless ion manipulations (SLIM). Guided by ion motion simulations, we designed elevator and escalator components based upon ion current measurements providing essentially lossless transmission in multilevel designs. The ion elevator design allowed ions to efficiently bridge a 4 mm gap between levels. The component was integrated in a SLIM and coupled to a QTOF mass spectrometer using an ion funnel interface to evaluate the m/z range transmitted as compared to transmission within a level (e.g., in a linear section). The analysis of singly charged ions of m/z 600-2700 produced similar mass spectra for both elevator and straight (linear motion) components. In the ion escalator design, traveling waves (TW) were utilized to transport ions efficiently between two SLIM levels. Ion current measurements and ion mobility (IM) spectrometry analysis illustrated that ions can be transported between TW-SLIM levels with no significant loss of either ions or IM resolution. These developments provide a path for the development of multilevel designs providing, e.g., much longer IM path lengths, more compact designs, and the implementation of much more complex SLIM devices in which, e.g., different levels may operate at different temperatures or with different gases.

  2. Two-dimensional boundary-value problem for ion-ion diffusion

    International Nuclear Information System (INIS)

    Tuszewski, M.; Lichtenberg, A.J.

    1977-01-01

    Like-particle diffusion is usually negligible compared with unlike-particle diffusion because it is two orders higher in spatial derivatives. When the ratio of the ion gyroradius to the plasma transverse dimension is of the order of the fourth root of the mass ratio, previous one-dimensional analysis indicated that like-particle diffusion is significant. A two-dimensional boundary-value problem for ion-ion diffusion is investigated. Numerical solutions are found with models for which the nonlinear partial differential equation reduces to an ordinary fourth-order differential equation. These solutions indicate that the ion-ion losses are higher by a factor of six for a slab geometry, and by a factor of four for circular geometry, than estimated from dimensional analysis. The solutions are applied to a multiple mirror experiment stabilized with a quadrupole magnetic field which generates highly elliptical flux surfaces. It is found that the ion-ion losses dominate the electron-ion losses and that these classical radial losses contribute to a significant decrease of plasma lifetime, in qualitiative agreement with the experimental results

  3. Analysis of femtogram-sized plutonium samples by thermal ionization mass spectrometry

    International Nuclear Information System (INIS)

    Smith, D.H.; Duckworth, D.C.; Bostick, D.T.; Coleman, R.M.; McPherson, R.L.; McKown, H.S.

    1994-01-01

    The goal of this investigation was to extend the ability to perform isotopic analysis of plutonium to samples as small as possible. Plutonium ionizes thermally with quite good efficiency (first ionization potential 5.7 eV). Sub-nanogram sized samples can be analyzed on a near-routine basis given the necessary instrumentation. Efforts in this laboratory have been directed at rhenium-carbon systems; solutions of carbon in rhenium provide surfaces with work functions higher than pure rhenium (5.8 vs. ∼ 5.4 eV). Using a single resin bead as a sample loading medium both concentrates the sample nearly to a point and, due to its interaction with rhenium, produces the desired composite surface. Earlier work in this area showed that a layer of rhenium powder slurried in solution containing carbon substantially enhanced precision of isotopic measurements for uranium. Isotopic fractionation was virtually eliminated, and ionization efficiencies 2-5 times better than previously measured were attained for both Pu and U (1.7 and 0.5%, respectively). The other side of this coin should be the ability to analyze smaller samples, which is the subject of this report

  4. Research program to investigate the fundamental chemistry of technetium

    Energy Technology Data Exchange (ETDEWEB)

    McKeown, David A.; Buechele, Andrew C.; Lukens, Wayne W.; Muller, Isabelle S.; Shuh, David K.; Pegg, Ian L.

    2007-10-12

    The objective of this research is to increase the knowledge of the fundamental technetium chemistry necessary to address challenges to the safe, long-term disposal of high-level nuclear waste posed by this element. The primary issues examined during the course of this project were the behavior of technetium and its surrogate rhenium during waste vitrification and glass corrosion. Since the redox behavior of technetium can play a large role in determining its volatility, one goal of this research was to better understand the behavior of technetium in glass as a function of the redox potential of the glass melt. In addition, the behavior of rhenium was examined, since rhenium is commonly used as a surrogate for technetium in waste vitrification studies. A number of glasses similar to Hanford Low Activity Waste (LAW) glasses were prepared under controlled atmospheres. The redox state of the glass was determined from the Fe(II)/Fe(III) ratio in the cooled glass, and the speciation of technetium and rhenium was determined by x-ray absorption fine structure (XAFS) spectroscopy. The behavior of rhenium and technetium during glass alteration was also examined using the vapor hydration test (VHT).

  5. Ion Acceleration by Double Layers with Multi-Component Ion Species

    Science.gov (United States)

    Good, Timothy; Aguirre, Evan; Scime, Earl; West Virginia University Team

    2017-10-01

    Current-free double layers (CFDL) models have been proposed to explain observations of magnetic field-aligned ion acceleration in plasmas expanding into divergent magnetic field regions. More recently, experimental studies of the Bohm sheath criterion in multiple ion species plasma reveal an equilibration of Bohm speeds at the sheath-presheath boundary for a grounded plate in a multipole-confined filament discharge. We aim to test this ion velocity effect for CFDL acceleration. We report high resolution ion velocity distribution function (IVDF) measurements using laser induced fluorescence downstream of a CFDL in a helicon plasma. Combinations of argon-helium, argon-krypton, and argon-xenon gases are ionized and measurements of argon or xenon IVDFs are investigated to determine whether ion acceleration is enhanced (or diminished) by the presence of lighter (or heavier) ions in the mix. We find that the predominant effect is a reduction of ion acceleration consistent with increased drag arising from increased gas pressure under all conditions, including constant total gas pressure, equal plasma densities of different ions, and very different plasma densities of different ions. These results suggest that the physics responsible for acceleration of multiple ion species in simple sheaths is not responsible for the ion acceleration observed in these expanding plasmas. Department of Physics, Gettysburg College.

  6. A singly charged ion source for radioactive 11C ion acceleration

    Science.gov (United States)

    Katagiri, K.; Noda, A.; Nagatsu, K.; Nakao, M.; Hojo, S.; Muramatsu, M.; Suzuki, K.; Wakui, T.; Noda, K.

    2016-02-01

    A new singly charged ion source using electron impact ionization has been developed to realize an isotope separation on-line system for simultaneous positron emission tomography imaging and heavy-ion cancer therapy using radioactive 11C ion beams. Low-energy electron beams are used in the electron impact ion source to produce singly charged ions. Ionization efficiency was calculated in order to decide the geometric parameters of the ion source and to determine the required electron emission current for obtaining high ionization efficiency. Based on these considerations, the singly charged ion source was designed and fabricated. In testing, the fabricated ion source was found to have favorable performance as a singly charged ion source.

  7. Ion microprobes

    International Nuclear Information System (INIS)

    Coles, J.N.; Long, J.V.P.

    1977-01-01

    An ion microprobe is described that has an ion extraction arrangement comprising two separate paths for ions and electrons diverging from a common point. A cone shaped or pyramidal guard electrode surrounds each path the apex angles being equal and coinciding with the said point. The guard electrodes are positioned to lie tangentially to each other and to a planar surface including the said point. An aperture is provided for the two paths at the apexes of both guard electrodes, and electrical connections between the guard electrodes enable the same potential to be applied to both guard electrodes. Means are provided for generating oppositely polarised electric fields within the guard electrodes, together with means for causing a focused ion beam to strike the common point without suffering astigmatism. The means for causing a focused ion beam to strike the said point includes an ion gun for directing an ion beam along one of the paths and means to provide an axial accelerating field there along. Optical viewing means are also provided. Existing designs enable only ions or electrons, but not both, to be extracted at any one time. (U.K.)

  8. Ion acoustic waves in one- and two-negative ion species plasmas

    International Nuclear Information System (INIS)

    Ichiki, Ryuta; Shindo, Masako; Yoshimura, Shinji; Watanabe, Tsuguhiro; Kawai, Yoshinobu

    2001-01-01

    Ion acoustic waves in multi-ion plasmas including two negative ion species are investigated both numerically and experimentally. Numerically, the kinetic dispersion relation in two-negative ion plasmas is investigated. There are three modes of the ion acoustic waves in two-negative ion plasmas. In an Ar + -F - -SF 6 - plasma, only one of the three modes is dominant, regardless of the values of the electron and the ion temperatures. In a Xe + -F - -SF 6 - plasma, on the other hand, two modes can be important for a certain range of the electron-ion temperature ratio. The results also imply the possibility of the coexistence of the fast mode and the slow mode in one-negative ion plasmas. Experimentally, ion acoustic waves are observed in an Ar + -F - -SF 6 - plasma and are found to show a mode transition that agrees with the theoretical prediction for one of the three ion acoustic modes

  9. Fusion at counterstreaming ion beams - ion optic fusion (IOF)

    International Nuclear Information System (INIS)

    Gryzinski, M.

    1981-01-01

    The results of investigation are briefly reviewed in the field of ion optic fusion performed at the Institute of Nuclear Research in Swierk. The ion optic fusion concept is based on the possibility of obtaining fusion energy at highly ordered motion of ions in counterstreaming ion beams. For this purpose TW ion beams must be produced and focused. To produce dense and charge-neutralized ion beams the selective conductivity and ballistic focusing ideas were formulated and used in a series of RPI devices with low-pressure cylindrical discharge between grid-type electrodes. 100 kA, 30 keV deuteron beams were successfully produced and focused into the volume of 1 cm 3 , yielding 10 9 neutrons per 200 ns shot on a heavy ice target. Cylindrically convergent ion beams with magnetic anti-defocusing were proposed in order to reach a positive energy gain at reasonable energy level. (J.U.)

  10. Synthesis and characterization of organohydrazino complexes of technetium, rhenium, and molybdenum with the [M(η1-HxNNR)(η2-HyNNR)] core and their relationship to radiolabeled organohydrazine-derivatives chemotactic peptides with diagnostic applications

    International Nuclear Information System (INIS)

    Rose, D.J.; Maresca, K.P.; Nicholson, T.

    1998-01-01

    In this paper, the authors present the details of the preparation of the imaging agent and its imaging properties. In order to define some structural possibilities for the coordination chemistry relevant to these reagents, they also present the results of investigations of the syntheses and structures of Tc, Mo, and Re complexes with hydrazinopyridine, which not only establish the formation of the robust unit, but also implicate chelate formation through the pyridine nitrogen as a significant structural determinant. The structures of the parent (bis)hydrazino-trichlorometalate core compounds are presented, allowing analysis of structural changes that occur when (2) protonation sites on the ligand change, (2) a different metal is employed, and (3) a different chelating hydrazine is utilized. The structures of the thiolate substitution products of these parent compounds are also presented. These derivatives demonstrate that rhenium and technetium have analogous substitution chemistry

  11. Ultra-small rhenium nanoparticles immobilized on DNA scaffolds: An excellent material for surface enhanced Raman scattering and catalysis studies.

    Science.gov (United States)

    Anantharaj, S; Sakthikumar, K; Elangovan, Ayyapan; Ravi, G; Karthik, T; Kundu, Subrata

    2016-12-01

    Highly Sensitive and ultra-small Rhenium (Re) metal nanoparticles (NPs) were successfully stabilized in water by the staging and fencing action of the versatile biomolecule DNA that resulted in two distinct aggregated chain-like morphologies with average grain sizes of 1.1±0.1nm and 0.7±0.1nm for the very first time within a minute of reaction time. Re NPs are formed by the borohydride reduction of ammonium perrhenate (NH4ReO4) in the presence of DNA at room temperature (RT) under stirring. The morphologies were controlled by carefully monitoring the molar ratio of NH4ReO4 and DNA. The synthesized material was employed in two potential applications: as a substrate for surface enhanced Raman scattering (SERS) studies and as a catalyst for the reduction of aromatic nitro compounds. SERS study was carried out by taking methylene blue (MB) as the probe and the highest SERS enhancement factor (EF) of 2.07×10(7) was found for the aggregated chain-like having average grain size of 0.7±0.1nm. Catalytic reduction of 4-nitro phenol (4-NP), 2-nitro phenol (2-NP) and 4-nitroaniline (4-NA) with a rate constant value of 6×10(-2)min(-1), 33.83×10(-2)min(-1) and 37.4×10(-2)min(-1) have testified the excellent catalytic performance of our Re NPs immobilized on DNA. The overall study have revealed the capability of DNA in stabilizing the highly reactive Re metal at nanoscale and made them applicable in practice. The present route can also be extended to prepare one dimensional (1-D), self-assembled NPs of other reactive metals, mixed metals or even metal oxides for specific applications in water based solutions. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Ions kinematics in an electrostatic ion beam trap

    Energy Technology Data Exchange (ETDEWEB)

    Attia, D

    2004-06-01

    In this study, I have tried to provide a better understanding of the dynamics of ions inside an electrostatic ion beam trap. The electrostatic ion trap allows to store ions moving between two electrostatic mirrors. Although the trap has been developed already seven years ago, no direct measurement of the transversal velocity distribution of the ions has been performed. Such quantity is central for understanding the conditions under which a beam should be produced (mainly emittance) in order to be trapped by such a device. The data I have obtained during the course of this work are based on an experimental technique which relies on the direct imaging of the particles exiting the trap, as well as on numerical simulations of the ion trajectories inside the trap. I have personally been involved in the hardware development of the imaging system, the data acquisition and analysis of the data as well as il all numerical calculations presented here. These results allow us to obtain, for the first time, experimental information on the transverse phase space of the trap, and contribute to the overall understanding of the ion motion in this system. (author)

  13. Isolation and activity determination of 99Tc in nuclear waste by liquid scintillation counting

    International Nuclear Information System (INIS)

    Reis Junior, Aluisio S.; Temba, Eliane S.C.; Kastner, Geraldo F.; Monteiro, Roberto P.G.

    2011-01-01

    A radiochemical separation and purification for technetium was proposed for radioactive waste in which rhenium is to be used as a yield monitor. The separation was performed by anion exchange chromatography and the purification was performed by extraction chromatography using a TEVA resin.The determination of 99 Tc was by liquid scintillation counting and rhenium was activated by Triga Mark 1 research reactor and measured by gamma spectrometry. Some real samples of nuclear waste such as evaporator concentrate and filter were analysed. The chemical recovery determined using rhenium as tracer was around 90 %. (author)

  14. Ion temperature via laser scattering on ion Bernstein waves

    International Nuclear Information System (INIS)

    Wurden, G.A.; Ono, M.; Wong, K.L.

    1981-10-01

    Hydrogen ion temperature has been measured in a warm toroidal plasma with externally launched ion Bernstein waves detected by heterodyne CO 2 laser scattering. Radial scanning of the laser beam allows precise determination of k/sub perpendicular to/ for the finite ion Larmor radius wave (ω approx. less than or equal to 2Ω/sub i/). Knowledge of the magnetic field strength and ion concentration then give a radially resolved ion temperature from the dispersion relation. Probe measurements and Doppler broadening of ArII 4806A give excellent agreement

  15. Diffuse ions produced by electromagnetic ion beam instabilities

    International Nuclear Information System (INIS)

    Winske, D.; Leroy, M.M.

    1984-01-01

    The evolution of the electromagnetic ions beam instability driven by the reflected ion component backstreaming away from the earth's how shock into the foreshock region is studied by means computer simulation. The linear the quasi-linear states of the instability are found to be in good agreement with known results for the resonant model propagating parallel to the beam along the magnetic field and with theory developed in this paper for the nonresonant mode, which propagates antiparallel to the beam direction. The quasi-linear stage, which produces large amplitude 8Bapprox.B, sinusoidal transverse waves and ''intermediate'' ion distribution, is terminated by a nonlinear phase in which strongly nonlinear, compressive waves and ''diffuse'' ion distributions are produced. Additional processes by which the diffuse ions are accelerated to observed high energies are not addressed. The results are discussed in terms of the ion distributions and hydromagnetic waves observed in the foreshock of the earth's bow shock and of interplanetary shocks

  16. Production of highly ionized recoil ions in heavy ion impact

    International Nuclear Information System (INIS)

    Tawara, H.; Tonuma, T.; Be, S.H.; Shibata, H.; Kase, M.; Kambara, T.; Kumagai, H.; Kohno, I.

    1985-01-01

    The production mechanisms of highly ionized recoil ions in energetic, highly charged heavy ion impact are compared with those in photon and electron impact. In addition to the innershell ionization processes which are important in photon and electron impact, the electron transfer processes are found to play a key role in heavy ion impact. In molecular targets are also observed highly ionized monoatomic ions which are believed to be produced through production of highly ionized molecular ions followed by prompt dissociation. The observed N 6+ ions produced in 1.05MeV/amu Ar 12+ ions on N 2 molecules are produced through, for example, N 2 12+ *→N 6+ +N 6+ process. (author)

  17. Ion optics in an ion source system

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Salam, F W; Moustafa, O A; El-Khabeary, H [Accelerators Dept, Nuclear Research Center, Atomic Energy Authority, Cairo (Egypt)

    1997-12-31

    An analysis of ion beams from an ion source which consisted of a hemispherical anode, a plane earthed cathode, and a focusing electrode has been carried out. The focal properties of such electrode arrangement were studied using axially symmetric fields. Axial and radial electric fields were obtained as functions of the axial distance. It was found that the radial component of the gradient of potential pushes the ions towards the axis, which indicates the convergent action of the system. The effect of voltage variation between the boundary and the focusing electrode on the position of the plasma boundary are given using the experimental data of the ion source characteristics and its geometrical parameters. The advantages of plasma diffusing outside the source through a small aperture were used by applying a potential to the focusing electrode. It was possible to extract a large ion current from the expanded plasma. The system constituted a lens with a focal length of 29.4 mm. 7 figs.

  18. Heavy ion beams from the new Hungarian ECR ion source

    International Nuclear Information System (INIS)

    Biri, S.; Valek, A.; Ditroi, F.; Koivisto, H.; Arje, J.; Stiebing, K.; Schmidt, L.

    1998-01-01

    The first beams of highly charged ions in Hungary were obtained in fall of 1996. The new 14.5 GHz ECR ion source of ATOMKI produced beams of multiply charged ions with remarkable intensities at first experiments. Since then, numerous further developments were carried out. An external electrondonor electrode drastically increased the plasma density and, consequently, the intensity of highly charged ions. These upgrades concentrated mainly on beams from gaseous elements and were carried out by the ECRIS team of ATOMKI. Another series of experiments - ionising from solids - however, was done in the framework of an international collaboration. The first metal ion beam has been extracted from the ECRIS in November 1997 using the known method of Metal Ions from Volatile Compounds (MIVOC). The possibility to put the MIVOC chamber inside the ion source was also tested and the dosing regulation problem of metal vapours inside the ion source was solved. As a result, beams of more than 10 μA of highly charged Fe and Ni ions were produced. (author)

  19. A Study of Ion-Ion Hybrid Instability in the Mixed Plasma

    Directory of Open Access Journals (Sweden)

    Soo-Yong Kim

    1987-12-01

    Full Text Available There are more oxygen ions than hydrogen ions in the auroral field zone. We consider both analytic and numerical simulation study of the heating of hydrogen and oxygen ions by auroral electrons. With the low drift speed of electron beams, the ion-ion hybrid wave becomes unstable instead of the lower hybrid wave so that a preferential heating of oxygen ions occurs.

  20. Heavy-ion radiography

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Tobias, C.A.; Holley, W.R.; Benton, E.V.; Woodruff, K.H.; MacFarland, E.W.

    1983-01-01

    High energy, heavy-ion beams offer superior discrimination of tissue electron densities at very low radiation doses. This characteristic has potential for diagnostic medical imaging of neoplasms arising in the soft tissues and organs because it can detect smaller inhomogeneities than x rays. Heavy-ion imaging may also increase the accuracy of cancer radiotherapy planning involving use of accelerated charged particles. In the current physics research program of passive heavy-ion imaging, critical modulation transfer function tests are being carried out in heavy-ion projection radiography and heavy-ion computerized tomography. The research goal is to improve the heavy-ion imaging method until it reaches the limits of its theoretical resolution defined by range straggling, multiple scattering, and other factors involved in the beam quality characteristics. Clinical uses of the imaging method include the application of heavy-ion computerized tomography to heavy-ion radiotherapy planning, to the study of brain tumors and other structures of the head, and to low-dose heavy-ion projection mammography, particularly for women with dense breasts where other methods of diagnosis fail. The ions used are primarily 300 to 570 MeV/amu carbon and neon ions accelerated at the Lawrence Berkeley Laboratory Bevalac

  1. Ion channels versus ion pumps: the principal difference, in principle.

    Science.gov (United States)

    Gadsby, David C

    2009-05-01

    The incessant traffic of ions across cell membranes is controlled by two kinds of border guards: ion channels and ion pumps. Open channels let selected ions diffuse rapidly down electrical and concentration gradients, whereas ion pumps labour tirelessly to maintain the gradients by consuming energy to slowly move ions thermodynamically uphill. Because of the diametrically opposed tasks and the divergent speeds of channels and pumps, they have traditionally been viewed as completely different entities, as alike as chalk and cheese. But new structural and mechanistic information about both of these classes of molecular machines challenges this comfortable separation and forces its re-evaluation.

  2. Note: Ion source design for ion trap systems

    Science.gov (United States)

    Noriega, J. R.; Quevedo, M.; Gnade, B.; Vasselli, J.

    2013-06-01

    A small plasma (glow discharge) based ion source and circuit are described in this work. The ion source works by producing a high voltage pulsed discharge between two electrodes in a pressure range of 50-100 mTorr. A third mesh electrode is used for ion extraction. The electrodes are small stainless steel screws mounted in a MACOR ionization chamber in a linear arrangement. The electrode arrangement is driven by a circuit, design for low power operation. This design is a proof of concept intended for applications on small cylindrical ion traps.

  3. High-ion temperature experiments with negative-ion-based NBI in LHD

    International Nuclear Information System (INIS)

    Takeiri, Y.; Morita, S.; Tsumori, K.; Ikeda, K.; Oka, Y.; Osakabe, M.; Nagaoka, K.; Goto, M.; Miyazawa, J.; Masuzaki, S.; Ashikawa, N.; Yokoyama, M.; Narihara, K.; Yamada, I.; Kubo, S.; Shimozuma, T.; Inagaki, S.; Tanaka, K.; Peterson, B.J.; Ida, K.; Kaneko, O.; Komori, A.; Murakami, S.

    2005-01-01

    High-Z plasmas have been produced with Ar- and/or Ne-gas fuelling to increase the ion temperature in the LHD plasmas heated with the high-energy negative-ion-based NBI. Although the electron heating is dominant in the high-energy NBI heating, the direct ion heating power is much enhanced effectively in low-density plasmas due to both an increase in the beam absorption (ionisation) power and a reduction of the ion density in the high-Z plasmas. Intensive Ne- and/or Ar-glow discharge cleaning works well to suppress dilution of the high-Z plasmas with the wall-absorbed hydrogen. As a result, the ion temperature increases with an increase in the ion heating power normalized by the ion density, and reaches 10 keV. An increase in the ion temperature is also observed with an addition of the centrally focused ECRH to the low-density and high-Z NBI plasma, suggesting improvement of the ion transport. The results obtained in the high-Z plasma experiments with the high-energy NBI heating indicate that an increase in the direct ion heating power and improvement of the ion transport are essential to the ion temperature rise, and that a high-ion temperature would be obtained as well in hydrogen plasmas with low-energy positive-NBI heating which is planed in near future in LHD. (author)

  4. Single ion hit detection set-up for the Zagreb ion microprobe

    Science.gov (United States)

    Smith, R. W.; Karlušić, M.; Jakšić, M.

    2012-04-01

    Irradiation of materials by heavy ions accelerated in MV tandem accelerators may lead to the production of latent ion tracks in many insulators and semiconductors. If irradiation is performed in a high resolution microprobe facility, ion tracks can be ordered by submicrometer positioning precision. However, full control of the ion track positioning can only be achieved by a reliable ion hit detection system that should provide a trigger signal irrespectively of the type and thickness of the material being irradiated. The most useful process that can be utilised for this purpose is emission of secondary electrons from the sample surface that follows the ion impact. The status report of the set-up presented here is based on the use of a channel electron multiplier (CEM) detector mounted on an interchangable sample holder that is inserted into the chamber in a close geometry along with the sample to be irradiated. The set-up has been tested at the Zagreb ion microprobe for different ions and energies, as well as different geometrical arrangements. For energies of heavy ions below 1 MeV/amu, results show that efficient (100%) control of ion impact can be achieved only for ions heavier than silicon. The successful use of the set-up is demonstrated by production of ordered single ion tracks in a polycarbonate film and by monitoring fluence during ion microbeam patterning of Foturan glass.

  5. Hierarchical architecture of ReS_2/rGO composites with enhanced electrochemical properties for lithium-ion batteries

    International Nuclear Information System (INIS)

    Qi, Fei; Chen, Yuanfu; Zheng, Binjie; He, Jiarui; Li, Qian; Wang, Xinqiang; Lin, Jie; Zhou, Jinhao; Yu, Bo; Li, Pingjian; Zhang, Wanli

    2017-01-01

    Highlights: • The ReS_2/rGO composites have been synthesized by a facile one-pot method. • The ReS_2/rGO composites exhibit hierarchical architecture. • The ReS_2/rGO composites deliver better electrochemical performances than ReS_2. • The enhanced performance is due to porous and conductive structure of ReS_2/rGO. - Abstract: Rhenium disulfide (ReS_2), a two-dimensional (2D) semiconductor, has attracted more and more attention due to its unique anisotropic electronic, optical, mechanical properties. However, the facile synthesis and electrochemical property of ReS_2 and its composite are still necessary to be researched. In this study, for the first time, the ReS_2/reduced graphene oxide (rGO) composites have been synthesized through a facile and one-pot hydrothermal method. The ReS_2/rGO composites exhibit a hierarchical, interconnected, and porous architecture constructed by nanosheets. As anode for lithium-ion batteries, the as-synthesized ReS_2/rGO composites deliver a large initial capacity of 918 mAh g"−"1 at 0.2 C. In addition, the ReS_2/rGO composites exhibit much better electrochemical cycling stability and rate capability than that of bare ReS_2. The significant enhancement in electrochemical property can be attributed to its unique architecture constructed by nanosheets and porous structure, which can allow for easy electrolyte infiltration, efficient electron transfer, and ionic diffusion. Furthermore, the graphene with high electronic conductivity can provide good conductive passageways. The facile synthesis approach can be extended to prepare other 2D transition metal dichalcogenides semiconductors for energy storage and catalytic application.

  6. Heavy-ion radiography and heavy-ion computed tomography

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Holley, W.R.; McFarland, E.W.; Tobias, C.a.

    1982-02-01

    Heavy-ion projection and CT radiography is being developed into a safe, low-dose, noninvasive radiological procedure that can quantitate and image small density differences in human tissues. The applications to heavy-ion mammography and heavy-ion CT imaging of the brain in clinical patients suggest their potential value in cancer diagnosis

  7. Study of the processes of ion pairs formation by the method of ion-ion coincidence: I2 and chlorine-containing hydrocarbons

    International Nuclear Information System (INIS)

    Golovin, A.V.

    1991-01-01

    A method of ion-ion coincidences was suggested to study the process of ion pairs formation during molecule photoionization. The principle of action of ion-ion coincidence method is based on recording of only the negative and positive ions that formed as a result of a molecule decomposition. The flowsheet of the facility of ion-ion coincidences was presented. The processes of ion pairs formation in iodine, chloroform, propyl-, n-propenyl-, tert.butyl- and benzyl-chlorides were studied. A simple model permitting to evaluate the dependence of quantum yield of ion pair formation on excitation energy was suggested

  8. High current vacuum arc ion source for heavy ion fusion

    International Nuclear Information System (INIS)

    Qi, N.; Schein, J.; Gensler, S.; Prasad, R.R.; Krishnan, M.; Brown, I.

    1999-01-01

    Heavy Ion fusion (HIF) is one of the approaches for the controlled thermonuclear power production. A source of heavy ions with charge states 1+ to 2+, in ∼0.5 A current beams with ∼20 micros pulse widths and ∼10 Hz repetition rates are required. Thermionic sources have been the workhorse for the HIF program to date, but suffer from sloe turn-on, heating problems for large areas, are limited to low (contact) ionization potential elements and offer relatively low ion fluxes with a charge state limited to 1+. Gas injection sources suffer from partial ionization and deleterious neutral gas effects. The above shortcomings of the thermionic ion sources can be overcome by a vacuum arc ion source. The vacuum arc ion source is a good candidate for HIF applications. It is capable of providing ions of various elements and different charge states, in short and long pulse bursts, with low emittance and high beam currents. Under a Phase-I STTR from DOE, the feasibility of the vacuum arc ion source for the HIF applications is investigated. An existing ion source at LBNL was modified to produce ∼0.5 A, ∼60 keV Gd (A∼158) ion beams. The experimental effort concentrated on beam noise reduction, pulse-to-pulse reproducibility and achieving low beam emittance at 0.5 A ion current level. Details of the source development will be reported

  9. Cs+ ion source for secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Bentz, B.L.; Weiss, H.; Liebl, H.

    1981-12-01

    Various types of cesium ionization sources currently used in secondary ion mass spectrometry are briefly reviewed, followed by a description of the design and performance of a novel, thermal surface ionization Cs + source developed in this laboratory. The source was evaluated for secondary ion mass spectrometry applications using the COALA ion microprobe mass analyzer. (orig.)

  10. Practical aspects of trapped ion mass spectrometry, 5 applications of ion trapping devices

    CERN Document Server

    March, Raymond E

    2009-01-01

    Examines ion/neutral and ion/ion reactions, ion spectroscopy, and the structural characterization of proteins and peptides using quadropole ion trap mass spectrometry, Fourier transform - ion cyclotron resonance (FT-ICR) mass spectrometry, and traveling wave ion mobility mass spectrometry.

  11. Laser ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Bykovskij, Yu

    1979-02-01

    The characteristics a laser source of multiply-ionized ions are described with regard to the interaction of laser radiation and matter, ion energy spectrum, angular ion distribution. The amount of multiple-ionization ions is evaluated. Out of laser source applications a laser injector of multiple-ionization ions and nuclei, laser mass spectrometry, laser X-ray microradiography, and a laser neutron generators are described.

  12. Compact RF ion source for industrial electrostatic ion accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyeok-Jung, E-mail: hjkwon@kaeri.re.kr; Park, Sae-Hoon; Kim, Dae-Il; Cho, Yong-Sub [Korea Multi-purpose Accelerator Complex, Korea Atomic Energy Research Institute, Gyeongsangbukdo 38180 (Korea, Republic of)

    2016-02-15

    Korea Multi-purpose Accelerator Complex is developing a single-ended electrostatic ion accelerator to irradiate gaseous ions, such as hydrogen and nitrogen, on materials for industrial applications. ELV type high voltage power supply has been selected. Because of the limited space, electrical power, and robust operation, a 200 MHz RF ion source has been developed. In this paper, the accelerator system, test stand of the ion source, and its test results are described.

  13. Compact RF ion source for industrial electrostatic ion accelerator

    Science.gov (United States)

    Kwon, Hyeok-Jung; Park, Sae-Hoon; Kim, Dae-Il; Cho, Yong-Sub

    2016-02-01

    Korea Multi-purpose Accelerator Complex is developing a single-ended electrostatic ion accelerator to irradiate gaseous ions, such as hydrogen and nitrogen, on materials for industrial applications. ELV type high voltage power supply has been selected. Because of the limited space, electrical power, and robust operation, a 200 MHz RF ion source has been developed. In this paper, the accelerator system, test stand of the ion source, and its test results are described.

  14. Programmable ion mobility spectrometer: Time resolution improvement and ion counter comparison

    International Nuclear Information System (INIS)

    Harrison, R.G.; Wilding, R.J.

    2005-01-01

    Atmospheric ion mobility spectrometers operating on the aspirated electrode principle require switching of a bias voltage to select ions of different mobility. The ion spectrum can be obtained by sweeping across a set of bias voltages. If rapid temporal changes in atmospheric ion spectra are to be measured, however, such as for a balloon-carried instrument, the sweep time across the ion spectrum must be kept short. As bias voltage steps can generate saturation in the mobility spectrometer's electrometer amplifier, the electrometer recovery time limits the ion mobility spectrum sweep rate. Here, active compensation of the charge injected at a bias voltage step is used to reduce the saturation time. Further, the optimal setting of the charge compensation circuitry provides a determination of the system capacitance, a necessary calibration parameter for absolute measurements. Using laboratory air, hourly variations in ion concentrations and air conductivity found using the voltage switching system were similar to those obtained with a traditional ion counter operating at a single mobility: ion growth, however, could only be detected using the ion spectrometer

  15. Development of ion-acoustic double layers through ion-acoustic fluctuations

    International Nuclear Information System (INIS)

    Sekar, A.N.; Saxena, Y.C.

    1985-01-01

    Experimental results on the formation of ion acoustic double layers resembling asymmetric ion-holes are presented. In a double plasma device, modified suitably to inject electron beam into the target plasma, modulation of the beam through step potential leads to excitation of ion-acoustic fluctuation. The ion-acoustic fluctuation, growing away from the grids separating source and target plasmas, developed into weak asymmetric ion-acoustic double layer. The observations are in qualitative agreement with theoretical models and computer simulations. (author)

  16. A laser ablation ion source for the FRS ion catcher

    Energy Technology Data Exchange (ETDEWEB)

    Rink, Ann-Kathrin; Ebert, Jens; Petrick, Martin; Reiter, Pascal [Justus Liebig Universitaet Giessen (Germany); Dickel, Timo; Geissel, Hans; Plass, Wolfgang; Scheidenberger, Christoph [Justus Liebig Universitaet Giessen (Germany); GSI, Darmstadt (Germany); Purushothamen, Sivaji [GSI, Darmstadt (Germany)

    2013-07-01

    The FRS Ion Catcher was developed to serve as test bench for the low energy branch of the Super FRS to slow down exotic nuclei and prepare them for further measurements/ experiments. It consists of a cryogenic stopping cell to thermalise the ions, a diagnostic unit for stopping cell characterisation and various radiofrequency quadrupole structures to guide the ions to the Multiple-Reflection Time-of-Flight Mass Spectrometer for mass measurements, α spectroscopy and isobar separation. To characterise the extraction times of the stopping cell, which is one of the main performance parameters of such a cell, a laser ablation ion source has been develped and tested. This ion source provides a sharply defined starting point of the ions for the extraction time measurement. In the future this source will provide reference ions to calibrate the mass spectrometer for accurate mass measurements.

  17. Ions and light

    CERN Document Server

    Bowers, Michael T

    2013-01-01

    Gas Phase Ion Chemistry, Volume 3: Ions and Light discusses how ions are formed by electron impact, ion-molecule reactions, or electrical discharge. This book discusses the use of light emitted by excited molecules to characterize either the chemistry that formed the excited ion, the structure of the excited ion, or both.Organized into 10 chapters, this volume begins with an overview of the extension of the classical flowing afterglow technique to include infrared and chemiluminescence and laser-induced fluorescence detection. This text then examines the experiments involving molecules that ar

  18. Heavy Ion Injection Into Synchrotrons, Based On Electron String Ion Sources

    CERN Document Server

    Donets, E E; Syresin, E M

    2004-01-01

    A possibility of heavy ions injection into synchrotrons is discussed on the base of two novel ion sources, which are under development JINR during last decade: 1) the electron string ion source (ESIS), which is a modified version of a conventional electron beam ion source (EBIS), working in a reflex mode of operation, and 2) the tubular electron string ion source (TESIS). The Electron String Ion Source "Krion-2" (VBLHE, JINR, Dubna) with an applied confining magnetic field of 3 T was used for injection into the superconducting JINR synchrotron - Nuclotron and during this runs the source provided a high pulse intensity of the highly charged ion beams: Ar16+

  19. Influence of nonelectrostatic ion-ion interactions on double-layer capacitance

    Science.gov (United States)

    Zhao, Hui

    2012-11-01

    Recently a Poisson-Helmholtz-Boltzmann (PHB) model [Bohinc , Phys. Rev. EPLEEE81539-375510.1103/PhysRevE.85.031130 85, 031130 (2012)] was developed by accounting for solvent-mediated nonelectrostatic ion-ion interactions. Nonelectrostatic interactions are described by a Yukawa-like pair potential. In the present work, we modify the PHB model by adding steric effects (finite ion size) into the free energy to derive governing equations. The modified PHB model is capable of capturing both ion specificity and ion crowding. This modified model is then employed to study the capacitance of the double layer. More specifically, we focus on the influence of nonelectrostatic ion-ion interactions on charging a double layer near a flat surface in the presence of steric effects. We numerically compute the differential capacitance as a function of the voltage under various conditions. At small voltages and low salt concentrations (dilute solution), we find out that the predictions from the modified PHB model are the same as those from the classical Poisson-Boltzmann theory, indicating that nonelectrostatic ion-ion interactions and steric effects are negligible. At moderate voltages, nonelectrostatic ion-ion interactions play an important role in determining the differential capacitance. Generally speaking, nonelectrostatic interactions decrease the capacitance because of additional nonelectrostatic repulsion among excess counterions inside the double layer. However, increasing the voltage gradually favors steric effects, which induce a condensed layer with crowding of counterions near the electrode. Accordingly, the predictions from the modified PHB model collapse onto those computed by the modified Poisson-Boltzmann theory considering steric effects alone. Finally, theoretical predictions are compared and favorably agree with experimental data, in particular, in concentrated solutions, leading one to conclude that the modified PHB model adequately predicts the diffuse

  20. Ion beam modification of solids ion-solid interaction and radiation damage

    CERN Document Server

    Wesch, Werner

    2016-01-01

    This book presents the method of ion beam modification of solids in realization, theory and applications in a comprehensive way. It provides a review of the physical basics of ion-solid interaction and on ion-beam induced structural modifications of solids. Ion beams are widely used to modify the physical properties of materials. A complete theory of ion stopping in matter and the calculation of the energy loss due to nuclear and electronic interactions are presented including the effect of ion channeling. To explain structural modifications due to high electronic excitations, different concepts are presented with special emphasis on the thermal spike model. Furthermore, general concepts of damage evolution as a function of ion mass, ion fluence, ion flux and temperature are described in detail and their limits and applicability are discussed. The effect of nuclear and electronic energy loss on structural modifications of solids such as damage formation, phase transitions and amorphization is reviewed for ins...

  1. A Study on the Ion Beam Extraction using Duo-PiGatron Ion source for Vertical Type Ion Beam Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bom Sok; Lee, Chan young; Lee, Jae Sang [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    In Korea Multipurpose Accelerator Complex (KOMAC), we have started ion beam service in the new beam utilization building since March this year. For various ion beam irradiation services, we are developed implanters such as metal (150keV/1mA), gaseous (200keV/5mA) and high current ion beam facility (20keV/150mA). One of the new one is a vertical type ion beam facility without acceleration tube (60keV/20mA) which is easy to install the sample. After the installation is complete, it is where you are studying the optimal ion beam extraction process. Detailed experimental results will be presented. Vertical Type Ion Beam Facility without acceleration tube of 60keV 20mA class was installed. We successfully extracted 60keV 20mA using Duo- PiGatron Ion source for Vertical Type Ion Beam Facility. Use the BPM and Faraday-cup, is being studied the optimum conditions of ion beam extraction.

  2. Reactions of atomic oxygen with the chlorate ion and the perchlorate ion

    Science.gov (United States)

    Anan'ev, Vladimir; Miklin, Mikhail; Kriger, Ludmila

    2014-06-01

    The reactions of the chlorate ion with atomic oxygen formed under photolysis of the nitrate ion introduced to potassium chlorate crystal by co-crystallization were studied by optical and infrared absorption spectroscopy. The perchlorate ion was found to form in solids as product of addition reaction of singlet atomic oxygen, formed under dissociation of the peroxynitrite ion - the product of isomerization of the excited nitrate ion. Triplet atomic oxygen does not react with the chlorate ion. The atomic oxygen formed under photolysis of the nitrate ion introduced to potassium perchlorate crystal by co-crystallization does not react with the perchlorate ion.

  3. Ion species stratification within strong shocks in two-ion plasmas

    Science.gov (United States)

    Keenan, Brett D.; Simakov, Andrei N.; Taitano, William T.; Chacón, Luis

    2018-03-01

    Strong collisional shocks in multi-ion plasmas are featured in many environments, with Inertial Confinement Fusion (ICF) experiments being one prominent example. Recent work [Keenan et al., Phys. Rev. E 96, 053203 (2017)] answered in detail a number of outstanding questions concerning the kinetic structure of steady-state, planar plasma shocks, e.g., the shock width scaling by the Mach number, M. However, it did not discuss shock-driven ion-species stratification (e.g., relative concentration modification and temperature separation). These are important effects since many recent ICF experiments have evaded explanation by standard, single-fluid, radiation-hydrodynamic (rad-hydro) numerical simulations, and shock-driven fuel stratification likely contributes to this discrepancy. Employing the state-of-the-art Vlasov-Fokker-Planck code, iFP, along with multi-ion hydro simulations and semi-analytics, we quantify the ion stratification by planar shocks with the arbitrary Mach number and the relative species concentration for two-ion plasmas in terms of ion mass and charge ratios. In particular, for strong shocks, we find that the structure of the ion temperature separation has a nearly universal character across ion mass and charge ratios. Additionally, we find that the shock fronts are enriched with the lighter ion species and the enrichment scales as M4 for M ≫ 1.

  4. Electron string ion sources for carbon ion cancer therapy accelerators

    Science.gov (United States)

    Boytsov, A. Yu.; Donets, D. E.; Donets, E. D.; Donets, E. E.; Katagiri, K.; Noda, K.; Ponkin, D. O.; Ramzdorf, A. Yu.; Salnikov, V. V.; Shutov, V. B.

    2015-08-01

    The type of the Electron String Ion Sources (ESIS) is considered to be the appropriate one to produce pulsed C4+ and C6+ ion beams for cancer therapy accelerators. In fact, the new test ESIS Krion-6T already now provides more than 1010 C4+ ions per pulse and about 5 × 109 C6+ ions per pulse. Such ion sources could be suitable to apply at synchrotrons. It has also been found that Krion-6T can provide more than 1011 C6+ ions per second at the 100 Hz repetition rate, and the repetition rate can be increased at the same or larger ion output per second. This makes ESIS applicable at cyclotrons as well. ESIS can be also a suitable type of ion source to produce the 11C radioactive ion beams. A specialized cryogenic cell was experimentally tested at the Krion-2M ESIS for pulse injection of gaseous species into the electron string. It has been shown in experiments with stable methane that the total conversion efficiency of methane molecules to C4+ ions reached 5%÷10%. For cancer therapy with simultaneous irradiation and precise dose control (positron emission tomography) by means of 11C, transporting to the tumor with the primary accelerated 11C4+ beam, this efficiency is preliminarily considered to be large enough to produce the 11C4+ beam from radioactive methane and to inject this beam into synchrotrons.

  5. Catalyst for disproportionation/double-bond isomerization of olefins

    International Nuclear Information System (INIS)

    Hughes, W.; Reusser, R.

    1980-01-01

    An activated calcined homogenous catalyst composition consists essentially of a support uranium and at least one of tungsten and rhenium, wherein said composition contains about 0.1 to 25 weight percent total uranium, tungsten, and rhenium, each calculated as the metal; and a weight ratio of uranium:at least one of tungsten and rhenium of about 2:1 to 1:1. The activated catalyst composition is prepared by steps which comprise forming a homogenous composite, calcining said homogenous composite in a molecular oxygen-containing atmosphere at elevated temperatures, and subsequently activating said calcined homogenous composite under reducing conditions at elevated temperatures. The catalyst composition according to claim 1 is one in which the total of uranium, tungsten, and rhenium is about 1 to 15 weight percent. The catalyst composition according to claim 2 is one in which the ratio of uranium to at least one of tungsten and rhenium is about 2:1 to 0.5:1. The catalyst composition according to claim 3 is one in which the support is alumina, silica, silica-alumina, zirconia, titania, thoria, aluminum phosphate, magnisium silicate, zinc aluminate, or mixture. The catalyst composition according to claim 4is one in which support is silica

  6. Preliminary Tests of a Paul ion Trap as an Ion Source

    Science.gov (United States)

    Sadat Kiai, S. M.; Zirak, A. R.; Elahi, M.; Adlparvar, S.; Mortazavi, B. N.; Safarien, A.; Farhangi, S.; Sheibani, S.; Alhooie, S.; Khalaj, M. M. A.; Dabirzadeh, A. A.; Ruzbehani, M.; Zahedi, F.

    2010-10-01

    The paper reports on the design and construction of a Paul ion trap as an ion source by using an impact electron ionization technique. Ions are produced in the trap and confined for the specific time which is then extracted and detected by a Faraday cup. Especial electronic configurations are employed between the end caps, ring electrodes, electron gun and a negative voltage for the detector. This configuration allows a constant low level of pure ion source between the pulsed confined ion sources. The present experimental results are based on the production and confinement of Argon ions with good stability and repeatability, but in principle, the technique can be used for various Argon like ions.

  7. GANIL Workshop on Ion Sources; Journees Sources d'Ions

    Energy Technology Data Exchange (ETDEWEB)

    Leroy, Renan [Grand Accelerateur National d' Ions Lourds (GANIL), 14 - Caen (France)

    1999-07-01

    The proceedings of the GANIL Workshop on Ion Sources held at GANIL - Caen on 18-19 March 1999 contains 13 papers aiming at improving the old source operation and developing new types of sources for nuclear research and studies of ion physics. A number of reports are devoted to applications like surface treatment, ion implantation or fusion injection. The 1+{yields}n+ transformation, charged particle transport in ECR sources, addition of cesium and xenon in negative ion sources and other basic issues in ion sources are also addressed.

  8. Review on heavy ion radiotherapy facilities and related ion sources (invited)

    International Nuclear Information System (INIS)

    Kitagawa, A.; Fujita, T.; Muramatsu, M.; Biri, S.; Drentje, A. G.

    2010-01-01

    Heavy ion radiotherapy awakens worldwide interest recently. The clinical results obtained by the Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences in Japan have clearly demonstrated the advantages of carbon ion radiotherapy. Presently, there are four facilities for heavy ion radiotherapy in operation, and several new facilities are under construction or being planned. The most common requests for ion sources are a long lifetime and good stability and reproducibility. Sufficient intensity has been achieved by electron cyclotron resonance ion sources at the present facilities.

  9. Quantitative ion implantation

    International Nuclear Information System (INIS)

    Gries, W.H.

    1976-06-01

    This is a report of the study of the implantation of heavy ions at medium keV-energies into electrically conducting mono-elemental solids, at ion doses too small to cause significant loss of the implanted ions by resputtering. The study has been undertaken to investigate the possibility of accurate portioning of matter in submicrogram quantities, with some specific applications in mind. The problem is extensively investigated both on a theoretical level and in practice. A mathematical model is developed for calculating the loss of implanted ions by resputtering as a function of the implanted ion dose and the sputtering yield. Numerical data are produced therefrom which permit a good order-of-magnitude estimate of the loss for any ion/solid combination in which the ions are heavier than the solid atoms, and for any ion energy from 10 to 300 keV. The implanted ion dose is measured by integration of the ion beam current, and equipment and techniques are described which make possible the accurate integration of an ion current in an electromagnetic isotope separator. The methods are applied to two sample cases, one being a stable isotope, the other a radioisotope. In both cases independent methods are used to show that the implantation is indeed quantitative, as predicted. At the same time the sample cases are used to demonstrate two possible applications for quantitative ion implantation, viz. firstly for the manufacture of calibration standards for instrumental micromethods of elemental trace analysis in metals, and secondly for the determination of the half-lives of long-lived radioisotopes by a specific activity method. It is concluded that the present study has advanced quantitative ion implantation to the state where it can be successfully applied to the solution of problems in other fields

  10. Rhenium(V) oxo complexes relevant to technetium renal imaging agents derived from mercaptoacetylglycylglycylaminobenzoic acid isomers. Structural and molecular mechanics studies

    International Nuclear Information System (INIS)

    Hansen, L.; Taylor, A. Jr; Marzilli, L.G.; Cini, R.

    1992-01-01

    The synthesis and characterization of three rhenium(V) oxo complexes derived from isomers of mercaptoacetylglycylglycylaminobenzoic acid (MAG 2 -ABAH 5 ) are reported. The isomers were synthesized from o-, m- and p-aminobenzoic acid and differed in the position of the terminal carboxyl group. The anions of 8-10, [ReO(MAG 2 -*ABAH)] - (* = para (8), meta (9), ortho (10)), contained the tetraanionic form of the ligands with the carboxyl group protonated. Compounds 8,9, and 10 were synthesized by exchange reactions of ReOCl 3 (Me 2 SO)(Ph 3 P) under moderate conditions and were isolated as [Ph 4 P] + , [Bu 4 N] + , and [Ph 4 P] + salts, respectively. The structures of 8 and 10 were determined by X-ray diffraction methods; except for the location of the carboxyl group, the structures are similar. The coordination geometry is pseudo square pyramidal, with nitrogen and sulfur donor atoms forming a square base and the oxo ligand at the apex. The orientation of the carboxyl group in 10 is anti to the Re double-bond O group. Since the carboxyl groups are protonated in 8 and 10 and in other relevant structures from this class of radiopharmaceuticals including [Ph 4 As][TcO(MAG 3 H)] (MAG 3 H = tetraanionic form of mercaptoacetyltriglycine), the authors developed molecular mechanics parameters that allowed them to calculate the structures of 8, 10, and [TcO(MAG 3 H)] - . They then extended the calculations to all three isomeric complexes in their deprotonated forms and to [TcO(MAG 3 )] 2- in order to approximate their solution phase structures. They conclude that the [TcO(MAG 3 )] 2- species is conformationally flexible, and they have made an initial assessment of structures vs renal clearance

  11. Ion-acoustic nonlinear periodic waves in electron-positron-ion plasma

    International Nuclear Information System (INIS)

    Chawla, J. K.; Mishra, M. K.

    2010-01-01

    Ion-acoustic nonlinear periodic waves, namely, ion-acoustic cnoidal waves have been studied in electron-positron-ion plasma. Using reductive perturbation method and appropriate boundary condition for nonlinear periodic waves, the Korteweg-de Vries (KdV) equation is derived for the system. The cnoidal wave solution of the KdV equation is discussed in detail. It is found that the frequency of the cnoidal wave is a function of its amplitude. It is also found that the positron concentration modifies the properties of the ion-acoustic cnoidal waves. The existence regions for ion-acoustic cnoidal wave in the parameters space (p,σ), where p and σ are the positron concentration and temperature ratio of electron to positron, are discussed in detail. In the limiting case these ion-acoustic cnoidal waves reduce to the ion-acoustic soliton solutions. The effect of other parameters on the characteristics of the nonlinear periodic waves is also discussed.

  12. Nanostructures by ion beams

    Science.gov (United States)

    Schmidt, B.

    Ion beam techniques, including conventional broad beam ion implantation, ion beam synthesis and ion irradiation of thin layers, as well as local ion implantation with fine-focused ion beams have been applied in different fields of micro- and nanotechnology. The ion beam synthesis of nanoparticles in high-dose ion-implanted solids is explained as phase separation of nanostructures from a super-saturated solid state through precipitation and Ostwald ripening during subsequent thermal treatment of the ion-implanted samples. A special topic will be addressed to self-organization processes of nanoparticles during ion irradiation of flat and curved solid-state interfaces. As an example of silicon nanocrystal application, the fabrication of silicon nanocrystal non-volatile memories will be described. Finally, the fabrication possibilities of nanostructures, such as nanowires and chains of nanoparticles (e.g. CoSi2), by ion beam synthesis using a focused Co+ ion beam will be demonstrated and possible applications will be mentioned.

  13. Metal Separations and Recovery in the Mining Industry

    Science.gov (United States)

    Izatt, Steven R.; Bruening, Ronald L.; Izatt, Neil E.

    2012-11-01

    Molecular Recognition Technology (MRT) plays an important role in the hydrometallurgical processing dissolved entities in solutions in the mining industry. The status of this industry with respect to sustainability and environmental issues is presented and discussed. The roles of MRT and ion exchange in metal separation and recovery processes in the mining industry are discussed and evaluated. Examples of MRT separation processes of interest to the mining community are given involving gold, cobalt purification by extraction of trace cadmium, rhenium, and platinum group metals (PGMs). MRT processes are shown to be sustainable, economically viable, energy efficient, and environmentally friendly, and to have a low carbon footprint.

  14. Sympathetic cooling of ions in a hybrid atom ion trap

    Energy Technology Data Exchange (ETDEWEB)

    Hoeltkemeier, Bastian

    2016-10-27

    In this thesis the dynamics of a trapped ion immersed in a spatially localized buffer gas is investigated. For a homogeneous buffer gas, the ion's energy distribution reaches a stable equilibrium only if the mass of the buffer gas atoms is below a critical value. This limitation can be overcome by using multipole traps in combination and/or a spatially confined buffer gas. Using a generalized model for elastic collisions of the ion with the buffer gas atoms, the ion's energy distribution is numerically determined for arbitrary buffer gas distributions and trap parameters. Three regimes characterized by the respective analytic form of the ion's equilibrium energy distribution are found. One of these is a novel regime at large atom-to-ion mass ratios where the final ion temperature can tuned by adiabatically decreasing the spatial extension of the buffer gas and the effective ion trap depth (forced sympathetic cooling). The second part of the thesis presents a hybrid atom ion trap designed for sympathetic cooling of hydroxide anions. In this hybrid trap the anions are immersed in a cloud of laser cooled rubidium atoms. The translational and rovibrational temperatures of the anions is probed by photodetachment tomography and spectroscopy which shows the first ever indication of sympathetic cooling of anions by laser cooled atoms.

  15. Oxidations of Organic and Inorganic Substrates by Superoxo-, hydroperoxo-, and oxo-compounds of the transition metals

    International Nuclear Information System (INIS)

    Michael John Vasbinder

    2006-01-01

    Chapters 1 and 2 dealt with the chemistry of superoxo-, hydroperoxo-, and oxo- complexes of chromium, rhodium and cobalt. Chapter 3 dealt with the mechanism of oxygen-atom transfer catalyzed by an oxo-complex of rhenium. In Chapter 1, it was shown that hydroperoxometal complexes of cobalt and rhodium react with superoxochromium and chromyl ions, generating reduced chromium species while oxidizing the hydroperoxometal ions to their corresponding superoxometal ions. It was shown that the chromyl and superoxochromium ions are the more powerful oxidants. Evidence supports hydrogen atom transfer from the hydroperoxometal ion to the oxidizing superoxochromium or chromyl ion as the reaction mechanism. There is a significant H/D kinetic isotope effect. Comparisons to the rate constants of other known hydrogen atom transfer reactions show the expected correlation with bond dissociation energies. In Chapter 2, it was found that the superoxometal complexes Cr aq OO 2+ and Rh(NH 3 ) 4 (H 2 O)OO 2+ oxidize stable nitroxyl radicals of the TEMPO series with rate constants that correlate with the redox potentials of both the oxidant and reductant. These reactions fit the Marcus equation for electron transfer near the theoretical value. Acid catalysis is important to the reaction, especially the thermodynamically limited cases involving Rh(NH 3 ) 4 (H 2 O)OO 2+ as the oxidant. The rate constants are notably less than those measured in the reaction between the same nitroxyl radicals and other strong free-radical oxidants, an illustration of the delocalized and stabilized nature of the superoxometal ions. Chapter 3 showed that oxo-rhenium catalysts needed a nucleophile to complete the catalytic oxygen-atom transfer from substituted pyridine-N-oxides to triphenylphosphine. The reaction was studied by introducing various pyridine-derived nucleophiles and monitoring their effect on the rate, then fitting the observed rate constants to the Hammett correlation. It was found that the

  16. Electron string ion sources for carbon ion cancer therapy accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Boytsov, A. Yu.; Donets, D. E.; Donets, E. D.; Donets, E. E.; Ponkin, D. O.; Ramzdorf, A. Yu.; Salnikov, V. V.; Shutov, V. B. [Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Katagiri, K.; Noda, K. [National Institute of Radiological Science, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan)

    2015-08-15

    The type of the Electron String Ion Sources (ESIS) is considered to be the appropriate one to produce pulsed C{sup 4+} and C{sup 6+} ion beams for cancer therapy accelerators. In fact, the new test ESIS Krion-6T already now provides more than 10{sup 10} C{sup 4+} ions per pulse and about 5 × 10{sup 9} C{sup 6+} ions per pulse. Such ion sources could be suitable to apply at synchrotrons. It has also been found that Krion-6T can provide more than 10{sup 11} C{sup 6+} ions per second at the 100 Hz repetition rate, and the repetition rate can be increased at the same or larger ion output per second. This makes ESIS applicable at cyclotrons as well. ESIS can be also a suitable type of ion source to produce the {sup 11}C radioactive ion beams. A specialized cryogenic cell was experimentally tested at the Krion-2M ESIS for pulse injection of gaseous species into the electron string. It has been shown in experiments with stable methane that the total conversion efficiency of methane molecules to C{sup 4+} ions reached 5%÷10%. For cancer therapy with simultaneous irradiation and precise dose control (positron emission tomography) by means of {sup 11}C, transporting to the tumor with the primary accelerated {sup 11}C{sup 4+} beam, this efficiency is preliminarily considered to be large enough to produce the {sup 11}C{sup 4+} beam from radioactive methane and to inject this beam into synchrotrons.

  17. Emission of positive oxygen ions from ion bombardment of adsorbate-covered metal surfaces

    International Nuclear Information System (INIS)

    Kaurin, M.G.

    1989-01-01

    During ion bombardment of metal surfaces, collision cascades can result in the emission of sputtered secondary ions. Recent experiments, however, have suggested that the emission of positive ions of electronegative adsorbates can result from electronic processes rather than from processes involving elastic collisions. This dissertation presents the results of experiments studying the emission of positive oxygen ions from oxygen- and carbon-monoxide-covered transition metal surfaces during bombardment by 25-250 keV ions of neon, argon, and krypton. The systems studied may be grouped into four categories. For a nickel substrate with adsorbed oxygen, the emission of positive oxygen ions proceeds through collision cascades. For titanium and niobium with adsorbed oxygen, the emission of positive oxygen ions is proportional to the primary ion velocity, consistent with emission from electronic processes; for a given primary ion velocity, the oxygen ion yield is independent of primary ion species. For substrates of molybdenum and tungsten, the oxygen yield is proportional to primary ion velocity, but the yield also depends on the primary ion species for a given primary ion velocity in a manner that is consistent with emission resulting from electronic processes. For these two groups, except for titanium, the yields during neon ion bombardment do not extrapolate (assuming linearity with primary ion velocity) to a nonzero value at zero beam velocity. The magnitude of the oxygen ion yields from these targets is not consistent with that expected if the emission were induced by secondary electrons emitted during the ion bombardment

  18. Systems and Methods for Ejection of Ions from an Ion Trap

    Science.gov (United States)

    Cooks, Robert Graham (Inventor); Snyder, Dalton (Inventor)

    2018-01-01

    The invention generally relates to systems and methods for ejection of ions from an ion trap. In certain embodiments, systems and methods of the invention sum two different frequency signals into a single summed signal that is applied to an ion trap. In other embodiments, an amplitude of a single frequency signal is modulated as the single frequency signal is being applied to the ion trap. In other embodiments, a first alternating current (AC) signal is applied to an ion trap that varies as a function of time, while a constant radio frequency (RF) signal is applied to the ion trap.

  19. 188Re(V) Nitrido Radiopharmaceuticals for Radionuclide Therapy.

    Science.gov (United States)

    Boschi, Alessandra; Martini, Petra; Uccelli, Licia

    2017-01-19

    The favorable nuclear properties of rhenium-188 for therapeutic application are described, together with new methods for the preparation of high yield and stable 188 Re radiopharmaceuticals characterized by the presence of the nitride rhenium core in their final chemical structure. 188 Re is readily available from an 188 W/ 188 Re generator system and a parallelism between the general synthetic procedures applied for the preparation of nitride technetium-99m and rhenium-188 theranostics radiopharmaceuticals is reported. Although some differences between the chemical characteristics of the two metallic nitrido fragments are highlighted, it is apparent that the same general procedures developed for the labelling of biologically active molecules with technetium-99m can be applied to rhenium-188 with minor modification. The availability of these chemical strategies, that allow the obtainment, in very high yield and in physiological condition, of 188 Re radiopharmaceuticals, gives a new attractive prospective to employ this radionuclide for therapeutic applications.

  20. 188Re(V) Nitrido Radiopharmaceuticals for Radionuclide Therapy

    Science.gov (United States)

    Boschi, Alessandra; Martini, Petra; Uccelli, Licia

    2017-01-01

    The favorable nuclear properties of rhenium-188 for therapeutic application are described, together with new methods for the preparation of high yield and stable 188Re radiopharmaceuticals characterized by the presence of the nitride rhenium core in their final chemical structure. 188Re is readily available from an 188W/188Re generator system and a parallelism between the general synthetic procedures applied for the preparation of nitride technetium-99m and rhenium-188 theranostics radiopharmaceuticals is reported. Although some differences between the chemical characteristics of the two metallic nitrido fragments are highlighted, it is apparent that the same general procedures developed for the labelling of biologically active molecules with technetium-99m can be applied to rhenium-188 with minor modification. The availability of these chemical strategies, that allow the obtainment, in very high yield and in physiological condition, of 188Re radiopharmaceuticals, gives a new attractive prospective to employ this radionuclide for therapeutic applications. PMID:28106830

  1. Ion Beam Propulsion Study

    Science.gov (United States)

    2008-01-01

    The Ion Beam Propulsion Study was a joint high-level study between the Applied Physics Laboratory operated by NASA and ASRC Aerospace at Kennedy Space Center, Florida, and Berkeley Scientific, Berkeley, California. The results were promising and suggested that work should continue if future funding becomes available. The application of ion thrusters for spacecraft propulsion is limited to quite modest ion sources with similarly modest ion beam parameters because of the mass penalty associated with the ion source and its power supply system. Also, the ion source technology has not been able to provide very high-power ion beams. Small ion beam propulsion systems were used with considerable success. Ion propulsion systems brought into practice use an onboard ion source to form an energetic ion beam, typically Xe+ ions, as the propellant. Such systems were used for steering and correction of telecommunication satellites and as the main thruster for the Deep Space 1 demonstration mission. In recent years, "giant" ion sources were developed for the controlled-fusion research effort worldwide, with beam parameters many orders of magnitude greater than the tiny ones of conventional space thruster application. The advent of such huge ion beam sources and the need for advanced propulsion systems for exploration of the solar system suggest a fresh look at ion beam propulsion, now with the giant fusion sources in mind.

  2. Electron-ion correlation effects in ion-atom single ionization

    Energy Technology Data Exchange (ETDEWEB)

    Colavecchia, F.D.; Garibotti, C.R. [Centro Atomico Bariloche and Consejo Nacional de Investigaciones Cientificas y Tecnicas, 8400 San Carlos de Bariloche (Argentina); Gasaneo, G. [Departamento de Fisica, Universidad Nacional del Sur, Av. Alem 1253, 8000 Bahia Blanca (Argentina)

    2000-06-28

    We study the effect of electron-ion correlation in single ionization processes of atoms by ion impact. We present a distorted wave model where the final state is represented by a correlated function solution of a non-separable three-body continuum Hamiltonian, that includes electron-ion correlation as coupling terms of the wave equation. A comparison of the electronic differential cross sections computed with this model with other theories and experimental data reveals that the influence of the electron-ion correlation is more significant for low energy emitted electrons. (author). Letter-to-the-editor.

  3. A quadrupole ion trap as low-energy cluster ion beam source

    CERN Document Server

    Uchida, N; Kanayama, T

    2003-01-01

    Kinetic energy distribution of ion beams was measured by a retarding field energy analyzer for a mass-selective cluster ion beam deposition system that uses a quadrupole ion trap as a cluster ion beam source. The results indicated that the system delivers a cluster-ion beam with energy distribution of approx 2 eV, which corresponded well to the calculation results of the trapping potentials in the ion trap. Using this deposition system, mass-selected hydrogenated Si cluster ions Si sub n H sub x sup + were actually deposited on Si(111)-(7x7) surfaces at impact kinetic energy E sub d of 3-30 eV. Observation by using a scanning tunneling microscope (STM) demonstrated that Si sub 6 H sub x sup + cluster ions landed on the surface without decomposition at E sub d =3 eV, while the deposition was destructive at E sub d>=18 eV. (author)

  4. Ion beam enhancement in magnetically insulated ion diodes for high-intensity pulsed ion beam generation in non-relativistic mode

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, X. P. [Key Laboratory of Materials Modification by Laser, Ion, and Electron Beams, Ministry of Education, Dalian University of Technology, Dalian 116024 (China); Surface Engineering Laboratory, School of Materials Science and Engineering, Dalian University of Technology, Dalian 116024 (China); Zhang, Z. C.; Lei, M. K., E-mail: surfeng@dlut.edu.cn [Surface Engineering Laboratory, School of Materials Science and Engineering, Dalian University of Technology, Dalian 116024 (China); Pushkarev, A. I. [Surface Engineering Laboratory, School of Materials Science and Engineering, Dalian University of Technology, Dalian 116024 (China); Laboratory of Beam and Plasma Technology, High Technologies Physics Institute, Tomsk Polytechnic University, 30, Lenin Ave, 634050 Tomsk (Russian Federation)

    2016-01-15

    High-intensity pulsed ion beam (HIPIB) with ion current density above Child-Langmuir limit is achieved by extracting ion beam from anode plasma of ion diodes with suppressing electron flow under magnetic field insulation. It was theoretically estimated that with increasing the magnetic field, a maximal value of ion current density may reach nearly 3 times that of Child-Langmuir limit in a non-relativistic mode and close to 6 times in a highly relativistic mode. In this study, the behavior of ion beam enhancement by magnetic insulation is systematically investigated in three types of magnetically insulated ion diodes (MIDs) with passive anode, taking into account the anode plasma generation process on the anode surface. A maximal enhancement factor higher than 6 over the Child-Langmuir limit can be obtained in the non-relativistic mode with accelerating voltage of 200–300 kV. The MIDs differ in two anode plasma formation mechanisms, i.e., surface flashover of a dielectric coating on the anode and explosive emission of electrons from the anode, as well as in two insulation modes of external-magnetic field and self-magnetic field with either non-closed or closed drift of electrons in the anode-cathode (A-K) gap, respectively. Combined with ion current density measurement, energy density characterization is employed to resolve the spatial distribution of energy density before focusing for exploring the ion beam generation process. Consistent results are obtained on three types of MIDs concerning control of neutralizing electron flows for the space charge of ions where the high ion beam enhancement is determined by effective electron neutralization in the A-K gap, while the HIPIB composition of different ion species downstream from the diode may be considerably affected by the ion beam neutralization during propagation.

  5. Recharging of a screened ion on the molecular ion

    International Nuclear Information System (INIS)

    Karbovanets, M.I.; Lazur, V.Yu.; Yudin, G.L.; Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR, Obninsk. Fiziko-Ehnergeticheskij Inst.)

    1987-01-01

    Charge exchange of a screened ion on a molecular ion is studied in the Oppenheimer-Brinkman-Cramers approximation. To calculate ion exchange probabilities and cross sections summed over the final degenerated electron states method of Green functions analogous to that applied earlier in the direct Coulomb excitation theory and atomic ionization is developed

  6. Negative Ion Density Fronts

    International Nuclear Information System (INIS)

    Igor Kaganovich

    2000-01-01

    Negative ions tend to stratify in electronegative plasmas with hot electrons (electron temperature Te much larger than ion temperature Ti, Te > Ti ). The boundary separating a plasma containing negative ions, and a plasma, without negative ions, is usually thin, so that the negative ion density falls rapidly to zero-forming a negative ion density front. We review theoretical, experimental and numerical results giving the spatio-temporal evolution of negative ion density fronts during plasma ignition, the steady state, and extinction (afterglow). During plasma ignition, negative ion fronts are the result of the break of smooth plasma density profiles during nonlinear convection. In a steady-state plasma, the fronts are boundary layers with steepening of ion density profiles due to nonlinear convection also. But during plasma extinction, the ion fronts are of a completely different nature. Negative ions diffuse freely in the plasma core (no convection), whereas the negative ion front propagates towards the chamber walls with a nearly constant velocity. The concept of fronts turns out to be very effective in analysis of plasma density profile evolution in strongly non-isothermal plasmas

  7. Multiply charged ions from solid substances with the mVINIS Ion Source

    International Nuclear Information System (INIS)

    Dragani, I; Nedeljkovi, T; Jovovi, J; Siljegovic, M; Dobrosavljevic, A

    2007-01-01

    We have used the well known metal-ions-from-volatile-compounds (MIVOC) method at the mVINIS Ion Source to produce the multiply charged ion beams form solid substances. Based on this method the very intense and stable multiply charged ion beams of several solid substances having the high melting points were extracted. The ion yields and the spectra of multiply charged ion beams obtained from solid materials like Fe and Hf will be presented. We have utilized the multiply charged ion beams from solid substances to irradiate the polymers, fullerenes and glassy carbon at the low energy channel for modification of materials

  8. Ion Selectivity Mechanism in a Bacterial Pentameric Ligand-Gated Ion Channel

    International Nuclear Information System (INIS)

    Wang, Hailong; Cheng, Xiaolin

    2011-01-01

    The proton-gated ion channel from Gloeobacter violaceus (GLIC) is a prokaryotic homolog of the eukaryotic nicotinic acetylcholine receptor (nAChR) that responds to the binding of neurotransmitter acetylcholine and mediates fast signal transmission. Recent emergence of a high resolution crystal structure of GLIC captured in a potentially open state allowed detailed, atomic-level insight into ion conduction and selectivity mechanisms in these channels. Herein, we have examined the barriers to ion conduction and origins of ion selectivity in the GLIC channel by the construction of potential of mean force (PMF) profiles for sodium and chloride ions inside the transmembrane region. Our calculations reveal that the GLIC channel is open for a sodium ion to transport, but presents a ∼10 kcal/mol free energy barrier for a chloride ion, which arises primarily from the unfavorable interactions with a ring of negatively charged glutamate residues (E-2) at the intracellular end and a ring of hydrophobic residues (I9) in the middle of the transmembrane domain. Our collective findings further suggest that the charge selection mechanism can, to a large extent, be attributed to the narrow intracellular end and a ring of glutamate residues in this position their strong negative electrostatics and ability to bind cations. By contrast, E19 at the extracellular entrance only plays a minor role in ion selectivity of GLIC. In addition to electrostatics, both ion hydration and protein dynamics are found to be crucial for ion conduction as well, which explains why a chloride ion experiences a much greater barrier than a sodium ion in the hydrophobic region of the pore.

  9. Partition/Ion-Exclusion Chromatographic Ion Stacking for the Analysis of Trace Anions in Water and Salt Samples by Ion Chromatography.

    Science.gov (United States)

    Akter, Fouzia; Saito, Shingo; Tasaki-Handa, Yuiko; Shibukawa, Masami

    2018-01-01

    A new analytical methodology for a simple and efficient on-line preconcentration of trace inorganic anions in water and salt samples prior to ion chromatographic determination is proposed. The preconcentration method is based on partition/ion-exclusion chromatographic ion stacking (PIEC ion stacking) with a hydrophilic polymer gel column containing a small amount of fixed anionic charges. The developed on-line PIEC ion stacking-ion chromatography method was validated by recovery experiments for the determination of nitrate in tap water in terms of both accuracy and precision, and the results showed the reliability of the method. The method proposed was also successfully applied to the determination of trace impurity nitrite and nitrate in reagent-grade salts of sodium sulfate. A low background level can be achieved since pure water is used as the eluant for the PIEC ion stacking. It is possible to reach sensitive detection at sub-μg L -1 levels by on-line PIEC ion stacking-ion chromatography.

  10. Development of a compact ECR ion source for various ion production

    Energy Technology Data Exchange (ETDEWEB)

    Muramatsu, M., E-mail: m-mura@nirs.go.jp; Hojo, S.; Iwata, Y.; Katagiri, K.; Sakamoto, Y.; Kitagawa, A. [National Institute of Radiological Sciences (NIRS), 4-9-1 Anagawa, Inage, Chiba 263-8555 (Japan); Takahashi, N. [Sumitomo Heavy Industries, Ltd., 19 Natsushima, Yokosuka, Kanagawa 237-8555 (Japan); Sasaki, N.; Fukushima, K.; Takahashi, K.; Suzuki, T.; Sasano, T. [Accelerator Engineering Corporation, 3-8-5 Konakadai, Inage, Chiba 263-0043 (Japan); Uchida, T.; Yoshida, Y. [Bio-Nano Electronics Research Centre, Toyo University, 2100 Kujirai, Kawagoe-shi, Saitama 350-8585 (Japan); Hagino, S.; Nishiokada, T.; Kato, Y. [Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita-shi, Osaka 565-0871 (Japan)

    2016-02-15

    There is a desire that a carbon-ion radiotherapy facility will produce various ion species for fundamental research. Although the present Kei2-type ion sources are dedicated for the carbon-ion production, a future ion source is expected that could provide: (1) carbon-ion production for medical use, (2) various ions with a charge-to-mass ratio of 1/3 for the existing Linac injector, and (3) low cost for modification. A prototype compact electron cyclotron resonance (ECR) ion source, named Kei3, based on the Kei series has been developed to correspond to the Kei2 type and to produce these various ions at the National Institute of Radiological Sciences (NIRS). The Kei3 has an outer diameter of 280 mm and a length of 1120 mm. The magnetic field is formed by the same permanent magnet as Kei2. The movable extraction electrode has been installed in order to optimize the beam extraction with various current densities. The gas-injection side of the vacuum chamber has enough space for an oven system. We measured dependence of microwave frequency, extraction voltage, and puller position. Charge state distributions of helium, carbon, nitrogen, oxygen, and neon were also measured.

  11. Molecular dynamics simulations of ion range profiles for heavy ions in light targets

    Energy Technology Data Exchange (ETDEWEB)

    Lan, C. [Department of Materials Science and Engineering, University of Tennessee, Knoxville, TN 37996 (United States); State Key Laboratory of Nuclear Physics and Technology, Peking University, 100871 (China); Xue, J.M. [State Key Laboratory of Nuclear Physics and Technology, Peking University, 100871 (China); Zhang, Y., E-mail: Zhangy1@ornl.gov [Department of Materials Science and Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Morris, J.R. [Department of Materials Science and Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Zhu, Z. [Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Gao, Y.; Wang, Y.G.; Yan, S. [State Key Laboratory of Nuclear Physics and Technology, Peking University, 100871 (China); Weber, W.J. [Department of Materials Science and Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States)

    2012-09-01

    The determination of stopping powers for slow heavy ions in targets containing light elements is important to accurately describe ion-solid interactions, evaluate ion irradiation effects and predict ion ranges for device fabrication and nuclear applications. Recently, discrepancies of up to 40% between the experimental results and SRIM (Stopping and Range of Ions in Matter) predictions of ion ranges for heavy ions with medium and low energies (<{approx}25 keV/nucleon) in light elemental targets have been reported. The longer experimental ion ranges indicate that the stopping powers used in the SRIM code are overestimated. Here, a molecular dynamics simulation scheme is developed to calculate the ion ranges of heavy ions in light elemental targets. Electronic stopping powers generated from both a reciprocity approach and the SRIM code are used to investigate the influence of electronic stopping on ion range profiles. The ion range profiles for Au and Pb ions in SiC and Er ions in Si, with energies between 20 and 5250 keV, are simulated. The simulation results show that the depth profiles of implanted ions are deeper and in better agreement with the experiments when using the electronic stopping power values derived from the reciprocity approach. These results indicate that the origin of the discrepancy in ion ranges between experimental results and SRIM predictions in the low energy region may be an overestimation of the electronic stopping powers used in SRIM.

  12. Ion implantation

    International Nuclear Information System (INIS)

    Johnson, E.

    1986-01-01

    It is the purpose of the present paper to give a review of surface alloy processing by ion implantation. However, rather than covering this vast subject as a whole, the survey is confined to a presentation of the microstructures that can be found in metal surfaces after ion implantation. The presentation is limited to alloys processed by ion implantation proper, that is to processes in which the alloy compositions are altered significantly by direct injection of the implanted ions. The review is introduced by a presentation of the processes taking place during development of the fundamental event in ion implantation - the collision cascade, followed by a summary of the various microstructures which can be formed after ion implantation into metals. This is compared with the variability of microstructures that can be achieved by rapid solidification processing. The microstructures are subsequently discussed in the light of the processes which, as the implantations proceed, take place during and immediately after formation of the individual collision cascades. These collision cascades define the volumes inside which individual ions are slowed down in the implanted targets. They are not only centres for vigorous agitation but also the sources for formation of excess concentrations of point defects, which will influence development of particular microstructures. A final section presents a selection of specific structures which have been observed in different alloy systems. (orig./GSCH)

  13. Transport of negative hydrogen and deuterium ions in RF-driven ion sources

    International Nuclear Information System (INIS)

    Gutser, R; Wuenderlich, D; Fantz, U

    2010-01-01

    Negative hydrogen ion sources are major components of neutral beam injection systems for plasma heating in future large-scale fusion experiments such as ITER. In order to fulfill the requirements of the ITER neutral beam injection, a high-performance, large-area RF-driven ion source for negative ions is being developed at the MPI fuer Plasmaphysik. Negative hydrogen ions are mainly generated on a converter surface by impinging neutral particles and positive ions under the influence of magnetic fields and the plasma sheath potential. The 3D transport code TrajAn has been applied in order to obtain the total and spatially resolved extraction probabilities for H - and D - ions under identical plasma parameters and the realistic magnetic field topology of the ion source. A comparison of the isotopes shows a lower total extraction probability in the case of deuterium ions, caused by a different transport effect. The transport calculation shows that distortions of the spatial distributions of ion birth and extraction by the magnetic electron suppression field are present for both negative hydrogen and deuterium ions.

  14. Tandem Mass Spectrometry and Ion Mobility Reveals Structural Insight into Eicosanoid Product Ion Formation.

    Science.gov (United States)

    Di Giovanni, James P; Barkley, Robert M; Jones, David N M; Hankin, Joseph A; Murphy, Robert C

    2018-04-23

    Ion mobility measurements of product ions were used to characterize the collisional cross section (CCS) of various complex lipid [M-H] - ions using traveling wave ion mobility mass spectrometry (TWIMS). TWIMS analysis of various product ions derived after collisional activation of mono- and dihydroxy arachidonate metabolites was found to be more complex than the analysis of intact molecular ions and provided some insight into molecular mechanisms involved in product ion formation. The CCS observed for the molecular ion [M-H] - and certain product ions were consistent with a folded ion structure, the latter predicted by the proposed mechanisms of product ion formation. Unexpectedly, product ions from [M-H-H 2 O-CO 2 ] - and [M-H-H 2 O] - displayed complex ion mobility profiles suggesting multiple mechanisms of ion formation. The [M-H-H 2 O] - ion from LTB 4 was studied in more detail using both nitrogen and helium as the drift gas in the ion mobility cell. One population of [M-H-H 2 O] - product ions from LTB 4 was consistent with formation of covalent ring structures, while the ions displaying a higher CCS were consistent with a more open-chain structure. Using molecular dynamics and theoretical CCS calculations, energy minimized structures of those product ions with the open-chain structures were found to have a higher CCS than a folded molecular ion structure. The measurement of product ion mobility can be an additional and unique signature of eicosanoids measured by LC-MS/MS techniques. Graphical Abstract ᅟ.

  15. Tandem Mass Spectrometry and Ion Mobility Reveals Structural Insight into Eicosanoid Product Ion Formation

    Science.gov (United States)

    Di Giovanni, James P.; Barkley, Robert M.; Jones, David N. M.; Hankin, Joseph A.; Murphy, Robert C.

    2018-04-01

    Ion mobility measurements of product ions were used to characterize the collisional cross section (CCS) of various complex lipid [M-H]- ions using traveling wave ion mobility mass spectrometry (TWIMS). TWIMS analysis of various product ions derived after collisional activation of mono- and dihydroxy arachidonate metabolites was found to be more complex than the analysis of intact molecular ions and provided some insight into molecular mechanisms involved in product ion formation. The CCS observed for the molecular ion [M-H]- and certain product ions were consistent with a folded ion structure, the latter predicted by the proposed mechanisms of product ion formation. Unexpectedly, product ions from [M-H-H2O-CO2]- and [M-H-H2O]- displayed complex ion mobility profiles suggesting multiple mechanisms of ion formation. The [M-H-H2O]- ion from LTB4 was studied in more detail using both nitrogen and helium as the drift gas in the ion mobility cell. One population of [M-H-H2O]- product ions from LTB4 was consistent with formation of covalent ring structures, while the ions displaying a higher CCS were consistent with a more open-chain structure. Using molecular dynamics and theoretical CCS calculations, energy minimized structures of those product ions with the open-chain structures were found to have a higher CCS than a folded molecular ion structure. The measurement of product ion mobility can be an additional and unique signature of eicosanoids measured by LC-MS/MS techniques. [Figure not available: see fulltext.

  16. An electron cyclotron resonance ion source based low energy ion beam platform

    International Nuclear Information System (INIS)

    Sun, L. T.; Shang, Y.; Ma, B. H.; Zhang, X. Z.; Feng, Y. C.; Li, X. X.; Wang, H.; Guo, X. H.; Song, M. T.; Zhao, H. Y.; Zhang, Z. M.; Zhao, H. W.; Xie, D. Z.

    2008-01-01

    To satisfy the requirements of surface and atomic physics study in the field of low energy multiple charge state ion incident experiments, a low energy (10 eV/q-20 keV/q) ion beam platform is under design at IMP. A simple test bench has been set up to test the ion beam deceleration systems. Considering virtues such as structure simplicity, easy handling, compactness, cost saving, etc., an all-permanent magnet ECRIS LAPECR1 [Lanzhou all-permanent magnet electron cyclotron resonance (ECR) ion source No. 1] working at 14.5 GHz has been adopted to produce intense medium and low charge state ion beams. LAPECR1 source has already been ignited. Some intense low charge state ion beams have been produced on it, but the first test also reveals that many problems are existing on the ion beam transmission line. The ion beam transmission mismatches result in the depressed performance of LAPECR1, which will be discussed in this paper. To obtain ultralow energy ion beam, after being analyzed by a double-focusing analyzer magnet, the selected ion beam will be further decelerated by two afocal deceleration lens systems, which is still under design. This design has taken into consideration both ions slowing down and also ion beam focusing. In this paper, the conceptual design of deceleration system will be discussed

  17. An electron cyclotron resonance ion source based low energy ion beam platform.

    Science.gov (United States)

    Sun, L T; Shang, Y; Ma, B H; Zhang, X Z; Feng, Y C; Li, X X; Wang, H; Guo, X H; Song, M T; Zhao, H Y; Zhang, Z M; Zhao, H W; Xie, D Z

    2008-02-01

    To satisfy the requirements of surface and atomic physics study in the field of low energy multiple charge state ion incident experiments, a low energy (10 eV/q-20 keV/q) ion beam platform is under design at IMP. A simple test bench has been set up to test the ion beam deceleration systems. Considering virtues such as structure simplicity, easy handling, compactness, cost saving, etc., an all-permanent magnet ECRIS LAPECR1 [Lanzhou all-permanent magnet electron cyclotron resonance (ECR) ion source No. 1] working at 14.5 GHz has been adopted to produce intense medium and low charge state ion beams. LAPECR1 source has already been ignited. Some intense low charge state ion beams have been produced on it, but the first test also reveals that many problems are existing on the ion beam transmission line. The ion beam transmission mismatches result in the depressed performance of LAPECR1, which will be discussed in this paper. To obtain ultralow energy ion beam, after being analyzed by a double-focusing analyzer magnet, the selected ion beam will be further decelerated by two afocal deceleration lens systems, which is still under design. This design has taken into consideration both ions slowing down and also ion beam focusing. In this paper, the conceptual design of deceleration system will be discussed.

  18. Ion-beam plasma and propagation of intense compensated ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Gabovich, M D [AN Ukrainskoj SSR, Kiev. Inst. Fiziki

    1977-02-01

    Discussed are the results of investigation of plasma properties received by neutralization of intense ion beam space charge. Considered is the process of ion beam compensation by charges, formed as a result of gas ionization by this beam or by externally introduced ones. Emphasis is placed on collective phenomena in ion-beam plasma, in particular on non-linear effects limiting amplitude of oscillations. It is shown that not only dynamic decompensation but the Coulomb collisions of ions with electrons as well as other collective oscillations significantly affects the propagation of compensated ion beams. All the processes are to be taken into account in solving the problem of obtaining ''superdense'' compensated beams.

  19. Ion-beam plasma and propagation of intense compensated ion beams

    International Nuclear Information System (INIS)

    Gabovich, M.D.

    1977-01-01

    Discussed are the results of investigation of plasma properties recieved by neutralization of intensive ion beam space charge. Considered is the process of ion beam compensation by charges, formed as a result of gas ionization by this beam or by externally introduced ones. Emphasis is placed on collective phenomena in ion-beam plasma, in particular on non-linear effects limiting amplitude of oscillations. It is shown, that not only dinamic decompensation but the Coulomb collisions of ions with electrons as well as other collective oscillations significantly affects the propagation of compensated ion beams. All the processes are to be taken into account at solving the problem of obtaining ''superdense'' compensated beams

  20. Ion source techniques for high-speed processing of material surface by ion beams

    International Nuclear Information System (INIS)

    Ishikawa, Junzo

    1990-01-01

    The present paper discusses some key or candidate techniques for future ion source development and such ion sources developed by the author. Several types of microwave ion sources for producing low charge state ions have been developed in Japan. When a microwave plasma cathode developed by the author is adapted to a Kaufman type ion source, the electron emission currents are found to be 2.5 A for argon gas and 0.5-0.9 A for oxygen gas. An alternative ionization method for metal atoms is strongly required for high-speed processing of material surface by metal-ion beams. Detailed discussion is made of collisional ionization of vaporized atoms, and negative-ion production (secondary negative-ion emission by sputtering). An impregnated electrode type liquid-metal ion source developed by the author, which has a porous tip structure, is described. The negative-ion production efficiency is quite high. The report also presents a neutral and ionized alkaline-metal bombardment type heavy negative-ion source, which consists of a cesium plasma ion source, suppressor, target electrode, negative-ion extraction electrode, and einzel lens. (N.K.)

  1. Fundamental processes determining the highly charged ion production in ECR ion sources

    International Nuclear Information System (INIS)

    Shirkov, G.D.

    1992-01-01

    The ion confinement and loss conditions in the open magnetic traps have been analyzed in this article. In EGRIS the the ions are confined in the negative potential well. The simultaneous application of ion cooling and pulse regime is proposed for pulse injection of highly charged ions in heavy ion accelerators and storage rings. 14 refs.; 3 figs

  2. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1983-01-01

    Ion-Selective Electrode Reviews, Volume 5 is a collection of articles that covers ion-speciation. The book aims to present the advancements of the range and capabilities of selective ion-sensors. The topics covered in the selection are neutral carrier based ion-selective electrodes; reference electrodes and liquid junction effects in ion-selective electrode potentiometry; ion transfer across water/organic phase boundaries and analytical; and carbon substrate ion-selective electrodes. The text will be of great use to chemists and chemical engineers.

  3. Electron Beam Ion Sources

    CERN Document Server

    Zschornacka, G.; Thorn, A.

    2013-12-16

    Electron beam ion sources (EBISs) are ion sources that work based on the principle of electron impact ionization, allowing the production of very highly charged ions. The ions produced can be extracted as a DC ion beam as well as ion pulses of different time structures. In comparison to most of the other known ion sources, EBISs feature ion beams with very good beam emittances and a low energy spread. Furthermore, EBISs are excellent sources of photons (X-rays, ultraviolet, extreme ultraviolet, visible light) from highly charged ions. This chapter gives an overview of EBIS physics, the principle of operation, and the known technical solutions. Using examples, the performance of EBISs as well as their applications in various fields of basic research, technology and medicine are discussed.

  4. ECR ion source based low energy ion beam facility

    Indian Academy of Sciences (India)

    Mass analyzed highly charged ion beams of energy ranging from a few keV to a few MeV plays an important role in various aspects of research in modern physics. In this paper a unique low energy ion beam facility (LEIBF) set up at Nuclear Science Centre (NSC) for providing low and medium energy multiply charged ion ...

  5. Ion-acoustic double layers in multi-species plasmas maintained by negative ions

    International Nuclear Information System (INIS)

    Verheest, F.

    1989-01-01

    A study is made of ion-acoustic double layers in a plasma consisting of any number of cold positive and negative ion (and cold electron) species in addition to one isothermal electron population. The Sagdeev potential is obtained in general, together with limits on both compressive and rarefactive solutions for ion-acoustic double layers and/or solitons. Weak ion-acoustic double layers are described by a modified Korteweg-de Vries equation. Such double layers are not possible in plasmas with only positive ion species and one electron population. When one or more negative ion and/or cold electron species are included above a certain threshold density, rarefactive ion-acoustic double layers occur, but no compressive ones. The double-layer form of the potential is given, together with an application to a plasma with one positive and one negative ion component. It is shown that there is indeed such a threshold density for the negative ion density, depending on the charge-to-mass ratios of both types of ions. The threshold density is determined numerically for a range of such ratios and discussed in view of possible relevance to auroral and experimental plasmas. In the discussion, cold electrons can play the role of the negative ion species. (author)

  6. An alkali ion source based on graphite intercalation compounds for ion mobility spectrometry

    International Nuclear Information System (INIS)

    Tabrizchi, Mahmoud; Hosseini, Zahra S

    2008-01-01

    A variety of alkali cation emitters were developed as the ion source for ion mobility spectrometry. The cation emitters were constructed based on alkali ion graphite intercalation compounds (GICs). The compounds were prepared by fusing alkali salts with ground graphite. In order to produce alkali ions, the compounds were loaded on a filament and heated to red. Reactant ions of the form alk + ions were observed for the alkali salts NaCl, KCl.LiCl, CsCl and SrCl. In addition to Na + ions, K + ions were observed at the beginning of thermionic emission from Na-GIC. This is due to the low ionization potential of potassium that exists in trace amounts in sodium salts. In addition to the potassium ion, Na + was observed in the case of LiCl salt. The Na + and K + peaks originating from impurities totally disappeared after about 40 min. However, the thermionic emission of the main ion of the corresponding salt lasted for several days. No negative ions were observed upon reversing the drift field. Selected organic compounds (methyl isobutyl ketone, dimethyl sulfoxide, acetone and tetrahydrofuran) were also ionized via alkali cation attachment reaction. Distinct ion mobility patterns were observed for different substances using one type of alkali reactant ion. However, the ion mobility pattern for a given substance changed when a different alkali reactant ion was used. Ammonia and amines were not ionized when this source was used

  7. Plasma ion sources and ion beam technology in microfabrications

    International Nuclear Information System (INIS)

    Ji, Lili

    2007-01-01

    For over decades, focused ion beam (FIB) has been playing a very important role in microscale technology and research, among which, semiconductor microfabrication is one of its biggest application area. As the dimensions of IC devices are scaled down, it has shown the need for new ion beam tools and new approaches to the fabrication of small-scale devices. In the meanwhile, nanotechnology has also deeply involved in material science research and bioresearch in recent years. The conventional FIB systems which utilize liquid gallium ion sources to achieve nanometer scale resolution can no longer meet the various requirements raised from such a wide application area such as low contamination, high throughput and so on. The drive towards controlling materials properties at nanometer length scales relies on the availability of efficient tools. In this thesis, three novel ion beam tools have been developed and investigated as the alternatives for the conventional FIB systems in some particular applications. An integrated focused ion beam (FIB) and scanning electron microscope (SEM) system has been developed for direct doping or surface modification. This new instrument employs a mini-RF driven plasma source to generate focused ion beam with various ion species, a FEI two-lens electron (2LE) column for SEM imaging, and a five-axis manipulator system for sample positioning. An all-electrostatic two-lens column has been designed to focus the ion beam extracted from the source. Based on the Munro ion optics simulation, beam spot sizes as small as 100 nm can be achieved at beam energies between 5 to 35 keV if a 5 (micro)m-diameter extraction aperture is used. Smaller beam spot sizes can be obtained with smaller apertures at sacrifice of some beam current. The FEI 2LE column, which utilizes Schottky emission, electrostatic focusing optics, and stacked-disk column construction, can provide high-resolution (as small as 20 nm) imaging capability, with fairly long working distance

  8. Gas phase ion chemistry

    CERN Document Server

    Bowers, Michael T

    1979-01-01

    Gas Phase Ion Chemistry, Volume 1 covers papers on the advances of gas phase ion chemistry. The book discusses the advances in flow tubes and the measurement of ion-molecule rate coefficients and product distributions; the ion chemistry of the earth's atmosphere; and the classical ion-molecule collision theory. The text also describes statistical methods in reaction dynamics; the state selection by photoion-photoelectron coincidence; and the effects of temperature and pressure in the kinetics of ion-molecule reactions. The energy distribution in the unimolecular decomposition of ions, as well

  9. Design of the compact ECR ion source for heavy-ion therapy

    International Nuclear Information System (INIS)

    Muramatsu, M.; Kitagawa, A.; Sato, S.; Sato, Y.; Yamada, S.; Hattori, T.; Shibuya, S.

    1999-01-01

    Heavy ion cancer treatment is successfully being done at the Heavy Ion Medical Accelerator in Chiba (HIMAC). Design philosophy for the ion sources for medical facilities are as follows: sufficient beam intensity, a few hundred eμA; long lifetime with good stability; easy operation and easy maintenance; and compactness. In order to develop such source for future heavy-ion facilities, we have tested compact electron cyclotron resonance (ECR) ion sources using permanent magnets both for axial and radial confinement of hot electrons. Since the yield of C 2+ ion in the firstly-developed source (2.45 GHz ECR) was 15 eμA and far below the medical requirement (-150 eμA for the HIMAC), a new source has been proposed, having the frequency of 10 GHz. The extracted intensity of C 4+ (and C 2+ ) ions is expected to be higher than 200 eμA. (author)

  10. Compression Ratio Ion Mobility Programming (CRIMP) Accumulation and Compression of Billions of Ions for Ion Mobility-Mass Spectrometry Using Traveling Waves in Structures for Lossless Ion Manipulations (SLIM)

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Liulin; Garimella, Venkata BS; Hamid, Ahmed M.; Webb, Ian K.; Attah, Isaac K.; Norheim, Randolph V.; Prost, Spencer A.; Zheng, Xueyun; Sandoval, Jeremy A.; Baker, Erin M.; Ibrahim, Yehia M.; Smith, Richard D.

    2017-05-25

    We report on the implementation of a traveling wave (TW) based compression ratio ion mobility programming (CRIMP) approach within Structures for Lossless Ion Manipulations (SLIM) that enables both greatly enlarged trapped ion charge capacities and also their subsequent efficient compression for use in ion mobility (IM) separations. Ion accumulation is conducted in a long serpentine path TW SLIM region after which CRIMP allows the large ion populations to be ‘squeezed’. The compression process occurs at an interface between two SLIM regions, one operating conventionally and the second having an intermittently pausing or ‘stuttering’ TW, allowing the contents of multiple bins of ions from the first region to be merged into a single bin in the second region. In this initial work stationary voltages in the second region were used to block ions from exiting the first (trapping) region, and the resumption of TWs in the second region allows ions to exit, and the population to also be compressed if CRIMP is applied. In our initial evaluation we show that the number of charges trapped for a 40 s accumulation period was ~5×109, more than two orders of magnitude greater than the previously reported charge capacity using an ion funnel trap. We also show that over 1×109 ions can be accumulated with high efficiency in the present device, and that the extent of subsequent compression is only limited by the space charge capacity of the trapping region. Lower compression ratios allow increased IM peak heights without significant loss of signal, while excessively large compression ratios can lead to ion losses and other artifacts. Importantly, we show that extended ion accumulation in conjunction with CRIMP and multiple passes provides the basis for a highly desirable combination of ultra-high sensitivity and ultra-high resolution IM separations using SLIM.

  11. Fast ion-atom and ion-molecule collisions

    CERN Document Server

    2013-01-01

    The principal goal of this book is to provide state-of-the art coverage of the non-relativistic three- and four-body theories at intermediate and high energy ion-atom and ion-molecule collisions. The focus is on the most frequently studied processes: electron capture, ionization, transfer excitation and transfer ionization. The content is suitable both for graduate students and experienced researchers. For these collisions, the literature has seen enormous renewal of activity in the development and applications of quantum-mechanical theories. This subject is of relevance in several branches of science and technology, like accelerator-based physics, the search for new sources of energy and high temperature fusion of light ions. Other important applications are in life sciences via medicine, where high-energy ion beams are used in radiotherapy for which a number of storage ring accelerators are in full operation, under construction or planned to be built worldwide. Therefore, it is necessary to review this fiel...

  12. Ion Concentration- and Voltage-Dependent Push and Pull Mechanisms of Potassium Channel Ion Conduction.

    Directory of Open Access Journals (Sweden)

    Kota Kasahara

    Full Text Available The mechanism of ion conduction by potassium channels is one of the central issues in physiology. In particular, it is still unclear how the ion concentration and the membrane voltage drive ion conduction. We have investigated the dynamics of the ion conduction processes in the Kv1.2 pore domain, by molecular dynamics (MD simulations with several different voltages and ion concentrations. By focusing on the detailed ion movements through the pore including selectivity filter (SF and cavity, we found two major conduction mechanisms, called the III-IV-III and III-II-III mechanisms, and the balance between the ion concentration and the voltage determines the mechanism preference. In the III-IV-III mechanism, the outermost ion in the pore is pushed out by a new ion coming from the intracellular fluid, and four-ion states were transiently observed. In the III-II-III mechanism, the outermost ion is pulled out first, without pushing by incoming ions. Increases in the ion concentration and voltage accelerated ion conductions, but their mechanisms were different. The increase in the ion concentrations facilitated the III-IV-III conductions, while the higher voltages increased the III-II-III conductions, indicating that the pore domain of potassium channels permeates ions by using two different driving forces: a push by intracellular ions and a pull by voltage.

  13. Fast-ion Dα measurements of the fast-ion distribution (invited)

    International Nuclear Information System (INIS)

    Heidbrink, W. W.

    2010-01-01

    The fast-ion Dα (FIDA) diagnostic is an application of charge-exchange recombination spectroscopy. Fast ions that neutralize in an injected neutral beam emit Balmer-α light with a large Doppler shift. The spectral shift is exploited to distinguish the FIDA emission from other bright sources of Dα light. Background subtraction is the main technical challenge. A spectroscopic diagnostic typically achieves temporal, energy, and transverse spatial resolution of ∼1 ms, ∼10 keV, and ∼2 cm, respectively. Installations that use narrow-band filters achieve high spatial and temporal resolution at the expense of spectral information. For high temporal resolution, the bandpass-filtered light goes directly to a photomultiplier, allowing detection of ∼50 kHz oscillations in FIDA signal. For two-dimensional spatial profiles, the bandpass-filtered light goes to a charge-coupled device camera; detailed images of fast-ion redistribution at instabilities are obtained. Qualitative and quantitative models relate the measured FIDA signals to the fast-ion distribution function. The first quantitative comparisons between theory and experiment found excellent agreement in beam-heated magnetohydrodynamics (MHD)-quiescent plasmas. FIDA diagnostics are now in operation at magnetic-fusion facilities worldwide. They are used to study fast-ion acceleration by ion cyclotron heating, to detect fast-ion transport by MHD modes and microturbulence, and to study fast-ion driven instabilities.

  14. Rearrangement reactions in ion-ion and ion-atom collisions: results and problems

    Energy Technology Data Exchange (ETDEWEB)

    Presnyakov, L.P. [Lebedev Physical Institute, Moscow (Russian Federation); Tawara, H.

    1997-01-01

    Recent experimental and theoretical results are discussed for ionic collisions with large cross sections at intermediate and small energies of the relative motion. Single- and double-electron removal from H{sup -} ions in slow collisions with other ions is considered in more details. The theoretical methods are discussed from the viewpoint of general requirements of scattering theory. (author)

  15. Ion-ion Recombination and Chemiion Concentrations In Aircraft Exhaust

    Science.gov (United States)

    Turco, R. P.; Yu, F.

    Jet aircraft emit large quantities of ultrafine volatile aerosols, as well as soot parti- cles, into the environment. To determine the long-term effects of these emissions, a better understanding of the mechanisms that control particle formation and evolution is needed, including the number and size dispersion. A recent explanation for aerosol nucleation in a jet wake involves the condensation of sulfuric acid vapor, and cer- tain organic compounds, onto charged molecular clusters (chemiions) generated in the engine combustors (Yu and Turco, 1997). Massive charged aggregates, along with sulfuric acid and organic precursor vapors, have been detected in jet plumes under cruise conditions. In developing the chemiion nucleation theory, Yu and Turco noted that ion-ion recombination in the engine train and jet core should limit the chemiion emission index to 1017/kg-fuel. This value is consistent with ion-ion recombination coefficients of 1×10-7 cm3/s over time scales of 10-2 s. However, the evolution of the ions through the engine has not been adequately studied. The conditions at the combustor exit are extreme-temperatures approach 1500 K, and pressures can reach 30 atmospheres. In this presentation, we show that as the combustion gases expand and cool, two- and three-body ion-ion recombination processes control the chemiion concentration. The concepts of mutual neutralization and Thomson recombination are first summarized, and appropriate temperature and pressure dependent recombination rate coefficients are derived for the aircraft problem. A model for ion losses in jet exhaust is then formulated using an "invariance" principle discussed by Turco and Yu (1997) in the context of a coagulating aerosol in an expanding plume. This recombina- tion model is applied to estimate chemiion emission indices for a range of operational engine conditions. The predicted ion emission rates are found to be consistent with observations. We discuss the sources of variance in chemiion

  16. A heavy ion pre-injector for the ICT-ion implanter

    International Nuclear Information System (INIS)

    Bhattacharya, P.K.; Gaonkar, S.; Wagh, A.G.; Hattangadi, V.A.; Sarma, N.

    1976-01-01

    A cheap and versatile hollow cathode electron bombardment ion source system including its ion extraction-cum-focussing assembly for obtaining intense heavy ion beams of solids and gases is described. The extractor region is designed to include more than 15deg total beam angle of extracted beam for producing focused ion current densities upto 60mA/cm 2 to serve as a pre-injector for the ICT(insulated core transformer) type ion implanter. The extraction-cum-focussing lens is a low aberration strong Einzel lens system of all araldite and metal construction with optical elements of proper quality and location to suit low voltage injection and subsequent ion analysis. The injection can be selected anywhere between 2 to 10 keV for singly charged ions with typical extraction currents of 500/μ, using a ring anode and a source aperture of 20 mil. Einzel lens focussing assembly allows continuous adjustment of the beam convergence to about 5deg and the beam size to approximately 5mm in diameter with about 10 KV central electrode potential. Test results of source characteristics for both the accelerating and decelerating model of beam formation have been made. (author)

  17. Upgraded vacuum arc ion source for metal ion implantation

    International Nuclear Information System (INIS)

    Nikolaev, A. G.; Oks, E. M.; Savkin, K. P.; Yushkov, G. Yu.; Brown, I. G.

    2012-01-01

    Vacuum arc ion sources have been made and used by a large number of research groups around the world over the past twenty years. The first generation of vacuum arc ion sources (dubbed ''Mevva,'' for metal vapor vacuum arc) was developed at Lawrence Berkeley National Laboratory in the 1980s. This paper considers the design, performance parameters, and some applications of a new modified version of this kind of source which we have called Mevva-V.Ru. The source produces broad beams of metal ions at an extraction voltage of up to 60 kV and a time-averaged ion beam current in the milliampere range. Here, we describe the Mevva-V.Ru vacuum arc ion source that we have developed at Tomsk and summarize its beam characteristics along with some of the applications to which we have put it. We also describe the source performance using compound cathodes.

  18. Squeezing of Ion Populations and Peaks in Traveling Wave Ion Mobility Separations and Structures for Lossless Ion Manipulations using Compression Ratio Ion Mobility Programming

    Energy Technology Data Exchange (ETDEWEB)

    Garimella, Venkata BS; Hamid, Ahmed M.; Deng, Liulin; Ibrahim, Yehia M.; Webb, Ian K.; Baker, Erin M.; Prost, Spencer A.; Norheim, Randolph V.; Anderson, Gordon A.; Smith, Richard D.

    2016-11-02

    In this work, we report an approach for spatial and temporal gas phase ion population manipulation, and demonstrate its application for the collapse of the ion distributions in ion mobility (IM) separations into tighter packets providing higher sensitivity measurements in conjunction with mass spectrometry (MS). We do this for ions moving from a conventionally traveling wave (TW)-driven region to a region where the TW is intermittently halted or ‘stuttered’. This approach causes the ion packets spanning a number of TW-created traveling traps (TT) to be redistributed into fewer TT, resulting in spatial compression. The degree of spatial compression is controllable and determined by the ratio of stationary time of the TW in the second region to its moving time. This compression ratio ion mobility programming (CRIMP) approach has been implemented using Structures for Lossless Ion Manipulations (SLIM) in conjunction with MS. CRIMP with the SLIM-MS platform is shown to provide increased peak intensities, reduced peak widths, and improved S/N ratios with MS detection. CRIMP also provides a foundation for extremely long path length and multi-pass IM separations in SLIM providing greatly enhanced IM resolution by reducing the detrimental effects of diffusional peak broadening due to increasing peak widths.

  19. Using Ion Exchange Chromatography to Separate and Quantify Complex Ions

    Science.gov (United States)

    Johnson, Brian J.

    2014-01-01

    Ion exchange chromatography is an important technique in the separation of charged species, particularly in biological, inorganic, and environmental samples. In this experiment, students are supplied with a mixture of two substitution-inert complex ions. They separate the complexes by ion exchange chromatography using a "flash"…

  20. Simulation study on ion extraction from ECR ion sources

    International Nuclear Information System (INIS)

    Fu, S.; Kitagawa, A.; Yamada, S.

    1993-07-01

    In order to study beam optics of NIRS-ECR ion source used in HIMAC, EGUN code has been modified to make it capable of modeling ion extraction from a plasma. Two versions of the modified code are worked out with two different methods in which 1-D and 2-D sheath theories are used respectively. Convergence problem of the strong nonlinear self-consistent equations is investigated. Simulations on NIRS-ECR ion source and HYPER-ECR ion source (in INS, Univ. of Tokyo) are presented in this paper, exhibiting an agreement with the experimental results. Some preliminary suggestions on the upgrading the extraction systems of these sources are also proposed. (author)

  1. Simulation study on ion extraction from ECR ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Fu, S.; Kitagawa, A.; Yamada, S.

    1993-07-01

    In order to study beam optics of NIRS-ECR ion source used in HIMAC, EGUN code has been modified to make it capable of modeling ion extraction from a plasma. Two versions of the modified code are worked out with two different methods in which 1-D and 2-D sheath theories are used respectively. Convergence problem of the strong nonlinear self-consistent equations is investigated. Simulations on NIRS-ECR ion source and HYPER-ECR ion source (in INS, Univ. of Tokyo) are presented in this paper, exhibiting an agreement with the experimental results. Some preliminary suggestions on the upgrading the extraction systems of these sources are also proposed. (author).

  2. Heavy ion program at BNL: AGS, RHIC [Relativistic Heavy Ion Collider

    International Nuclear Information System (INIS)

    Barton, D.S.

    1987-01-01

    With the recent commissioning of fixed target, heavy ion physics at the AGS, Brookhaven National Laboratory (BNL) has embarked on a long range program in support of relativistic heavy ion research. Acceleration of low mass heavy ions (up to sulfur) to an energy of about 14.5 GeV/nucleon is possible with the direct connection of the BNL Tandem Van de Graaff and AGS accelerators. When completed, the new booster accelerator will provide heavy ions over the full mass range for injection and subsequent acceleration in the AGS. BNL is now engaged in an active R and D program directed toward the proposed Relativistic Heavy Ion Collider (RHIC). The results of the first operation of the low mass heavy ion program will be reviewed, and future expectations discussed. The expected performance for the heavy ion operation of the booster will be described and finally, the current status and outlook for the RHIC facility will be presented

  3. The heavy ion injection scheme for RHIC [Relativistic Heavy Ion Collider

    International Nuclear Information System (INIS)

    Rhoades-Brown, M.J.

    1989-01-01

    The Relativistic Heavy Ion Collider (RHIC) at Brookhaven has a multi-component injection system. The Collider requires very heavy ions such as 79 197 Au to be injected fully stripped of atomic electrons, at a kinetic energy of approximately 10 GeV/nucleon. However, the heavy ions are produced initially at a negative ion source and accelerated first in a 15 MV Tandem. These partially stripped ions have a kinetic energy of approximately 1 MeV/nucleon on leaving the Tandem. In order to achieve the injection requirements for RHIC, the partially stripped ions are accelerated in the Booster (currently under construction) and pass through a stripping foil on their way to the Alternating Gradient Synchrotron (AGS), where they are further accelerated before injection into RHIC. Recent theoretical calculations have shown quite convincingly that very heavy ions with 2 electrons in the filled K-shell may be accelerated with negligible loss in the AGS. 13 refs., 3 figs., 3 tabs

  4. Auroral ion beams and ion acoustic wave generation by fan instability

    Energy Technology Data Exchange (ETDEWEB)

    Vaivads, A

    1996-04-01

    Satellite observations indicate that efficient energy transport among various plasma particles and between plasma waves and plasma particles is taking place in auroral ion beam regions. These observations show that two characteristic wave types are associated with the auroral ion beam regions: electrostatic hydrogen cyclotron waves with frequencies above hydrogen gyrofrequency, and low frequency waves with frequencies below hydrogen gyrofrequency. We speculate that the low frequency waves can be ion acoustic waves generated through the fan instability. The presence of a cold background ion component is necessary for the onset of this instability. A cold ion component has been directly observed and has been indirectly suggested from observations of solitary wave structures. The wave-particle interaction during the development of the fan instability results in an efficient ion beam heating in the direction perpendicular to the ambient magnetic field. The fan instability development and the ion beam heating is demonstrated in a numerical particle simulation. 23 refs, 16 figs.

  5. Ion Trapping, Storage, and Ejection in Structures for Lossless Ion Manipulations.

    Science.gov (United States)

    Zhang, Xinyu; Garimella, Sandilya V B; Prost, Spencer A; Webb, Ian K; Chen, Tsung-Chi; Tang, Keqi; Tolmachev, Aleksey V; Norheim, Randolph V; Baker, Erin S; Anderson, Gordon A; Ibrahim, Yehia M; Smith, Richard D

    2015-06-16

    A new Structures for Lossless Ion Manipulations (SLIM) module, having electrode arrays patterned on a pair of parallel printed circuit boards (PCB), was constructed and utilized to investigate capabilities for ion trapping at a pressure of 4 Torr. Positive ions were confined by application of RF voltages to a series of inner rung electrodes with alternating phase on adjacent electrodes, in conjunction with positive DC potentials on surrounding guard electrodes on each PCB. An axial DC field was also introduced by stepwise varying the DC potentials applied to the inner rung electrodes to control the ion transport and accumulation inside the ion trapping region. We show that ions can be trapped and accumulated with up to 100% efficiency, stored for at least 5 h with no significant losses, and then could be rapidly ejected from the SLIM trap. The present results provide a foundation for the development of much more complex SLIM devices that facilitate extended ion manipulations.

  6. Numerical Simulation of Ion Transport in a Nano-Electrospray Ion Source at Atmospheric Pressure

    Science.gov (United States)

    Wang, Wei; Bajic, Steve; John, Benzi; Emerson, David R.

    2018-03-01

    Understanding ion transport properties from the ion source to the mass spectrometer (MS) is essential for optimizing device performance. Numerical simulation helps in understanding of ion transport properties and, furthermore, facilitates instrument design. In contrast to previously reported numerical studies, ion transport simulations in a continuous injection mode whilst considering realistic space-charge effects have been carried out. The flow field was solved using Reynolds-averaged Navier-Stokes (RANS) equations, and a particle-in-cell (PIC) method was applied to solve a time-dependent electric field with local charge density. A series of ion transport simulations were carried out at different cone gas flow rates, ion source currents, and capillary voltages. A force evaluation analysis reveals that the electric force, the drag force, and the Brownian force are the three dominant forces acting on the ions. Both the experimental and simulation results indicate that cone gas flow rates of ≤250 slph (standard liter per hour) are important for high ion transmission efficiency, as higher cone gas flow rates reduce the ion signal significantly. The simulation results also show that the ion transmission efficiency reduces exponentially with an increased ion source current. Additionally, the ion loss due to space-charge effects has been found to be predominant at a higher ion source current, a lower capillary voltage, and a stronger cone gas counterflow. The interaction of the ion driving force, ion opposing force, and ion dispersion is discussed to illustrate ion transport mechanism in the ion source at atmospheric pressure. [Figure not available: see fulltext.

  7. Development of novel strategy for the synthesis of organometallic compounds usable as protein ligands: application to the human cyclophilin hCyp-18; Developpement de ligands de proteines par assemblage combinatoire autour d'un coeur de rhenium{sup V}: application a la cyclophiline hCyp-18

    Energy Technology Data Exchange (ETDEWEB)

    Clavaud, C

    2006-02-15

    This thesis describes a new strategy for the development of bioactive organometallic compounds, basing on the combinatorial assembly of sub-chemical libraries (A and B) independent but complementary and able to coordinate a metallic heart M to form A-M-B complex potential ligands of biomolecules. The coordination of metals, well adapted to the production of molecular variety is usually used in medicinal chemistry, in diagnostic and therapeutic nuclear medicine. Among the useful elements, the rhenium and the technetium are metals of choice for the development of the assembly strategy because of their chemical and radiochemical properties and of the structure analogy of their complexes. This strategy was validated in vitro. The protein chosen for this purpose was the cyclophilin hCyp-18. (N.C.)

  8. Development of industrial ion implantation and ion assisted coating processes: A perspective

    International Nuclear Information System (INIS)

    Legg, K.O.; Solnick-Legg, H.

    1989-01-01

    Ion beam processes have gone through a series of developmental stages, from being the mainstay of the semiconductor industry for production of integrated circuits, to new commercial processes for biomedical, aerospace and other industries. Although research is still continuing on surface modification using ion beam methods, ion implantation and ion assisted coatings for treatment of metals, ceramics, polymers and composites must now be considered viable industrial processes of benefit in a wide variety of applications. However, ion implantation methods face various barriers to acceptability, in terms not only of other surface treatment processes, but for implantation itself. This paper will discuss some of the challenges faced by a small company whose primary business is development and marketing of ion implantation and ion-assisted coating processes. (orig.)

  9. Fully kinetic simulation of ion acoustic and dust-ion acoustic waves

    International Nuclear Information System (INIS)

    Hosseini Jenab, S. M.; Kourakis, I.; Abbasi, H.

    2011-01-01

    A series of numerical simulations is presented, based on a recurrence-free Vlasov kinetic model using kinetic phase point trajectories. All plasma components are modeled kinetically via a Vlasov evolution equation, then coupled through Poisson's equation. The dynamics of ion acoustic waves in an electron-ion and in a dusty (electron-ion-dust) plasma configuration are investigated, focusing on wave decay due to Landau damping and, in particular, on the parametric dependence of the damping rate on the dust concentration and on the electron-to-ion temperature ratio. In the absence of dust, the occurrence of damping was observed, as expected, and its dependence to the relative magnitude of the electron vs ion temperature(s) was investigated. When present, the dust component influences the charge balance, enabling dust-ion acoustic waves to survive Landau damping even in the extreme regime where T e ≅ T i . The Landau damping rate is shown to be minimized for a strong dust concentration or/and for a high value of the electron-to-ion temperature ratio. Our results confirm earlier theoretical considerations and contribute to the interpretation of experimental observations of dust-ion acoustic wave characteristics.

  10. Neutralized ion beam modification of cellulose membranes for study of ion charge effect on ion-beam-induced DNA transfer

    Science.gov (United States)

    Prakrajang, K.; Sangwijit, K.; Anuntalabhochai, S.; Wanichapichart, P.; Yu, L. D.

    2012-02-01

    Low-energy ion beam biotechnology (IBBT) has recently been rapidly developed worldwide. Ion-beam-induced DNA transfer is one of the important applications of IBBT. However, mechanisms involved in this application are not yet well understood. In this study plasma-neutralized ion beam was applied to investigate ion charge effect on induction of DNA transfer. Argon ion beam at 7.5 keV was neutralized by RF-driven plasma in the beam path and then bombarded cellulose membranes which were used as the mimetic plant cell envelope. Electrical properties such as impedance and capacitance of the membranes were measured after the bombardment. An in vitro experiment on plasmid DNA transfer through the cellulose membrane was followed up. The results showed that the ion charge input played an important role in the impedance and capacitance changes which would affect DNA transfer. Generally speaking, neutral particle beam bombardment of biologic cells was more effective in inducing DNA transfer than charged ion beam bombardment.

  11. Response of thermal ions to electromagnetic ion cyclotron waves

    Science.gov (United States)

    Anderson, B. J.; Fuselier, S. A.

    1994-01-01

    Electromagnetic ion cyclotron waves generated by 10 - 50 keV protons in the Earth's equatorial magnetosphere will interact with the ambient low-energy ions also found in this region. We examine H(+) and He(+) distribution functions from approx. equals 1 to 160 eV using the Hot Plasma Composition Experiment instrument on AMPTE/CCE to investigate the thermal ion response to the waves. A total of 48 intervals were chosen on the basis of electromagnetic ion cyclotron (EMIC) wave activity: 24 with prevalent EMIC waves and 24 with no EMIC waves observed on the orbit. There is a close correlation between EMIC waves and perpendicular heated ion distributions. For protons the perpendicular temperature increase is modest, about 5 eV, and is always observed at 90 deg pitch angles. This is consistent with a nonresonant interaction near the equator. By contrast, He(+) temperatures during EMIC wave events averaged 35 eV and sometimes exceeded 100 eV, indicating stronger interaction with the waves. Furthermore, heated He(+) ions have X-type distributions with maximum fluxes occurring at pitch angles intermediate between field-aligned and perpendicular directions. The X-type He(+) distributions are consistent with a gyroresonant interaction off the equator. The concentration of He(+) relative to H(+) is found to correlate with EMIC wave activity, but it is suggested that the preferential heating of He(+) accounts for the apparent increase in relative He(+) concentration by increasing the proportion of He(+) detected by the ion instrument.

  12. Production of C, N, O, and Ne ions by pulsed ion source and acceleration of these ions in the cyclotron

    International Nuclear Information System (INIS)

    Nakajima, Hisao; Kohara, Shigeo; Kageyama, Tadashi; Kohno, Isao

    1977-01-01

    The heavy ion source, of electron bombarded hot cathode type, is usually operated by applying direct current for arc discharge. In order to accelerate Ne 6+ ion in the cyclotron, a pulsed operation of this source was attempted. Ne 6+ and O 6+ ions were accelerated successfully up to 160 MeV and more than 0.1 μA of these ion were extracted from the cyclotron. C 5+ , Ne 7+ and 22 Ne 6+ ions were also extracted with a modest intensity of beam. The intensity of C 4+ , N 4+ , N 5+ , and O 5+ ions was increased about ten times. (auth.)

  13. Hybrid Lithium-ion Capacitor / Lithium-ion Battery System for Extended Performance

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed task will involve the design of a hybrid power system with lithium-ion (li-ion) capacitors (LICs), li-ion batteries and solar cells. The challenge in...

  14. Metal negative ion beam extraction from a radio frequency ion source

    Energy Technology Data Exchange (ETDEWEB)

    Kanda, S.; Yamada, N.; Kasuya, T.; Romero, C. F. P.; Wada, M.

    2015-04-08

    A metal ion source of magnetron magnetic field geometry has been designed and operated with a Cu hollow target. Radio frequency power at 13.56 MHz is directly supplied to the hollow target to maintain plasma discharge and induce self-bias to the target for sputtering. The extraction of positive and negative Cu ion beams have been tested. The ion beam current ratio of Cu{sup +} to Ar{sup +} has reached up to 140% when Ar was used as the discharge support gas. Cu{sup −} ion beam was observed at 50 W RF discharge power and at a higher Ar gas pressure in the ion source. Improvement of poor RF power matching and suppression of electron current is indispensable for a stable Cu{sup −} ion beam production from the source.

  15. Ion-temperature-gradient-driven modes in bi-ion magnetoplasma

    Energy Technology Data Exchange (ETDEWEB)

    Batool, Nazia; Mirza, Arshad M [Theoretical Plasma Physics Group, Department of Physics, Quaid-i-Azam University, Islamabad 45320 (Pakistan); Qamar, Anisa [Department of Physics, Peshawar University, NWFP 25120 (Pakistan)], E-mail: nazia.batool@ncp.edu.pk

    2008-12-15

    The toroidal ion-temperature-gradient (ITG)-driven electrostatic drift waves are investigated for bi-ion plasmas with equilibrium density, temperature and magnetic field gradients. Using Braginskii's transport equations for the ions and Boltzmann distributed electrons, the mode coupling equations are derived. New ITG-driven modes are shown to exist. The results of the present study should be helpful to understand several wave phenomena in space and tokamak plasmas.

  16. Proceedings of the 'INS workshop on ECR ion sources for multiply-charged heavy ions'

    International Nuclear Information System (INIS)

    1995-02-01

    This workshop was held on December 1 and 2, 1994 at the Institute for Nuclear Study, University of Tokyo. The performance of ion sources is crucial for all researches and applications that use ion beam. The performance of ECR ion sources is strongly dependent on heuristic knowledge and innovation. From these viewpoints, it is useful to exchange information on the status of the existing sources, the performance of the new sources, and the design of the future sources between the source builders and the users. There were unexpected more than 70 participants and 20 contributions. The lectures were given on the present status of NIRS-ECR, SF-ECR, INS ISOL-ECR, RCNP ECR and EBIS ion sources, the production of multiply charged metallic ions with Hyper ECR or by plasma cathode method, the processing of ceramic rods and the ion production with OCTOPUS, the modeling of multi-charged ion production, the design of an advanced minimum B for ECR multi-charged ion source, the design, construction and operation of 18 GHz HiECR ion source, the construction and test operation of JAERI 18 GHz ion source, the design of an ECR ion source for the HIMAC, a 14.5 GHz ECR ion source at RIKEN, TMU 14 GHz ECR ion source, ''NANOGAN'' ECR ion source and its irradiation system, the optimization of the ECR ion source for optically pumped polarized ion source and so on. (K.I.)

  17. Proceedings of the `INS workshop on ECR ion sources for multiply-charged heavy ions`

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-01

    This workshop was held on December 1 and 2, 1994 at the Institute for Nuclear Study, University of Tokyo. The performance of ion sources is crucial for all researches and applications that use ion beam. The performance of ECR ion sources is strongly dependent on heuristic knowledge and innovation. From these viewpoints, it is useful to exchange information on the status of the existing sources, the performance of the new sources, and the design of the future sources between the source builders and the users. There were unexpected more than 70 participants and 20 contributions. The lectures were given on the present status of NIRS-ECR, SF-ECR, INS ISOL-ECR, RCNP ECR and EBIS ion sources, the production of multiply charged metallic ions with Hyper ECR or by plasma cathode method, the processing of ceramic rods and the ion production with OCTOPUS, the modeling of multi-charged ion production, the design of an advanced minimum B for ECR multi-charged ion source, the design, construction and operation of 18 GHz HiECR ion source, the construction and test operation of JAERI 18 GHz ion source, the design of an ECR ion source for the HIMAC, a 14.5 GHz ECR ion source at RIKEN, TMU 14 GHz ECR ion source, ``NANOGAN`` ECR ion source and its irradiation system, the optimization of the ECR ion source for optically pumped polarized ion source and so on. (K.I.).

  18. Specific ion effects on membrane potential and the permselectivity of ion exchange membranes.

    Science.gov (United States)

    Geise, Geoffrey M; Cassady, Harrison J; Paul, Donald R; Logan, Bruce E; Hickner, Michael A

    2014-10-21

    Membrane potential and permselectivity are critical parameters for a variety of electrochemically-driven separation and energy technologies. An electric potential is developed when a membrane separates electrolyte solutions of different concentrations, and a permselective membrane allows specific species to be transported while restricting the passage of other species. Ion exchange membranes are commonly used in applications that require advanced ionic electrolytes and span technologies such as alkaline batteries to ammonium bicarbonate reverse electrodialysis, but membranes are often only characterized in sodium chloride solutions. Our goal in this work was to better understand membrane behaviour in aqueous ammonium bicarbonate, which is of interest for closed-loop energy generation processes. Here we characterized the permselectivity of four commercial ion exchange membranes in aqueous solutions of sodium chloride, ammonium chloride, sodium bicarbonate, and ammonium bicarbonate. This stepwise approach, using four different ions in aqueous solution, was used to better understand how these specific ions affect ion transport in ion exchange membranes. Characterization of cation and anion exchange membrane permselectivity, using these ions, is discussed from the perspective of the difference in the physical chemistry of the hydrated ions, along with an accompanying re-derivation and examination of the basic equations that describe membrane potential. In general, permselectivity was highest in sodium chloride and lowest in ammonium bicarbonate solutions, and the nature of both the counter- and co-ions appeared to influence measured permselectivity. The counter-ion type influences the binding affinity between counter-ions and polymer fixed charge groups, and higher binding affinity between fixed charge sites and counter-ions within the membrane decreases the effective membrane charge density. As a result permselectivity decreases. The charge density and polarizability

  19. Space-charge compensation of highly charged ion beam from laser ion source

    International Nuclear Information System (INIS)

    Kondrashev, S.A.; Collier, J.; Sherwood, T.R.

    1996-01-01

    The problem of matching an ion beam delivered by a high-intensity ion source with an accelerator is considered. The experimental results of highly charged ion beam transport with space-charge compensation by electrons are presented. A tungsten thermionic cathode is used as a source of electrons for beam compensation. An increase of ion beam current density by a factor of 25 is obtained as a result of space-charge compensation at a distance of 3 m from the extraction system. The process of ion beam space-charge compensation, requirements for a source of electrons, and the influence of recombination losses in a space-charge-compensated ion beam are discussed. (author)

  20. Ion sources for initial use at the Holifield radioactive ion beam facility

    International Nuclear Information System (INIS)

    Alton, G.D.

    1994-01-01

    The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the HRIBF because of its low emittance, relatively high ionization efficiencies and species versatility, and because it has been engineered for remote installation, removal and servicing as required for safe handling in a high-radiation-level ISOL facility. Prototype plasma-sputter negative ion sources and negative surfaceionization sources are also under design consideration for generating negative radioactive ion beams from high electron-affinity elements. A brief review of the HRIBF will be presented, followed by a detailed description of the design features, operational characteristics, ionization efficiencies, and beam qualities (emittances) of these sources

  1. Evaluation of Negative-Ion-Beam Driver Concepts for Heavy Ion Fusion

    International Nuclear Information System (INIS)

    Grisham, Larry R.

    2002-01-01

    We evaluate the feasibility of producing and using atomically neutral heavy ion beams produced from negative ions as drivers for an inertial confinement fusion reactor. Bromine and iodine appear to be the most attractive elements for the driver beams. Fluorine and chlorine appear to be the most appropriate feedstocks for initial tests of extractable negative ion current densities. With regards to ion sources, photodetachment neutralizers, and vacuum requirements for accelerators and beam transport, this approach appears feasible within existing technology, and the vacuum requirements are essentially identical to those for positive ion drivers except in the target chamber. The principal constraint is that this approach requires harder vacuums in the target chamber than do space-charge-neutralized positive ion drivers. With realistic (but perhaps pessimistic) estimates of the total ionization cross section, limiting the ionization of a neutral beam to less than 5% while traversing a four -meter path would require a chamber pressure of no more than 5 x 10 -5 torr. Alternatively, even at chamber pressures that are too high to allow propagation of atomically neutral beams, the negative ion approach may still have appeal, since it precludes the possibly serious problem of electron contamination of a positive ion beam during acceleration, drift compression, and focusing

  2. The ion polytropic coefficient in a collisionless sheath containing hot ions

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Binbin; Xiang, Nong, E-mail: xiangn@ipp.ac.cn; Ou, Jing [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Center for Magnetic Fusion Theory, Chinese Academy of Sciences, Hefei 230031 (China)

    2016-08-15

    The fluid approach has been widely used to study plasma sheath dynamics. For a sheath containing hot ions whose temperature is greater than the electron's, how to truncate the fluid hierarchy chain equations while retaining to the fullest extent of the kinetic effects is always a difficult problem. In this paper, a one-dimensional, collisionless sheath containing hot ions is studied via particle-in-cell simulations. By analyzing the ion energy equation and taking the kinetic effects into account, we have shown that the ion polytropic coefficient in the vicinity of the sheath edge is approximately constant so that the state equation with the modified polytropic coefficient can be used to close the hierarchy chain of the ion fluid equations. The value of the polytropic coefficient strongly depends on the hot ion temperature and its concentration in the plasma. The semi-analytical model is given to interpret the simulation results. As an application, the kinetic effects on the ion saturation current density in the probe theory are discussed.

  3. Ion mobility spectrometry

    CERN Document Server

    Eiceman, GA

    2005-01-01

    Key Developments for Faster, More Precise Detection Capabilities Driven by the demand for the rapid and advanced detection of explosives, chemical and biological warfare agents, and narcotics, ion mobility spectrometry (IMS) undergone significant refinements in technology, computational capabilities, and understanding of the principles of gas phase ion chemistry and mobility. Beginning with a thorough discussion of the fundamental theories and physics of ion mobility, Ion Mobility Spectrometry, Second Edition describes the recent advances in instrumentation and newly

  4. Duopigatron ion source studies

    International Nuclear Information System (INIS)

    Bacon, F.M.; Bickes, R.W. Jr.; O'Hagan, J.B.

    1978-07-01

    Ion source performance characteristics consisting of total ion current, ion energy distribution, mass distribution, and ion current density distribution were measured for several models of a duopigatron. Variations on the duopigatron design involved plasma expansion cup material and dimensions, secondary cathode material, and interelectrode spacings. Of the designs tested, the one with a copper and molybdenum secondary cathode and a mild steel plasma expansion cup proved to give the best results. The ion current density distribution was peaked at the center of the plasma expansion cup and fell off to 80 percent of the peak value at the cup wall for a cup 15.2 mm deep. A total ion current of 180 mA consisting of 60 to 70 percent atomic ions was produced with an arc current of 20 A and source pressure of 9.3 Pa. More shallow cups produced a larger beam current and a more sharply peaked ion current density distribution. Typical ion energy distributions were bell-shaped curves with a peak 10 to 20 V below anode potential and with ion energies extending 30 to 40 V on either side of the peak

  5. C-terminal peptide extension via gas-phase ion/ion reactions

    Science.gov (United States)

    Peng, Zhou; McLuckey, Scott A.

    2015-01-01

    The formation of peptide bonds is of great importance from both a biological standpoint and in routine organic synthesis. Recent work from our group demonstrated the synthesis of peptides in the gas-phase via ion/ion reactions with sulfo-NHS reagents, which resulted in conjugation of individual amino acids or small peptides to the N-terminus of an existing ‘anchor’ peptide. Here, we demonstrate a complementary approach resulting in the C-terminal extension of peptides. Individual amino acids or short peptides can be prepared as reagents by incorporating gas phase-labile protecting groups to the reactive C-terminus and then converting the N-terminal amino groups to the active ketenimine reagent. Gas-phase ion/ion reactions between the anionic reagents and doubly protonated “anchor” peptide cations results in extension of the “anchor” peptide with new amide bond formation at the C-terminus. We have demonstrated that ion/ion reactions can be used as a fast, controlled, and efficient means for C-terminal peptide extension in the gas phase. PMID:26640400

  6. Cobalt alloy ion sources for focused ion beam implantation

    Energy Technology Data Exchange (ETDEWEB)

    Muehle, R.; Doebeli, M. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Zimmermann, P. [Eidgenoessische Technische Hochschule, Zurich (Switzerland)

    1997-09-01

    Cobalt alloy ion sources have been developed for silicide formation by focused ion beam implantation. Four eutectic alloys AuCo, CoGe, CoY and AuCoGe were produced by electron beam welding. The AuCo liquid alloy ion source was investigated in detail. We have measured the emission current stability, the current-voltage characteristics, and the mass spectrum as a function of the mission current. (author) 1 fig., 2 refs.

  7. Studies on indigenous ion exchange resins: alkali metal ions-hydrogen ion exchange equilibria

    International Nuclear Information System (INIS)

    Shankar, S.; Kumar, Surender; Venkataramani, B.

    2001-01-01

    With a view to select a suitable ion exchange resin for the removal of radionuclides (such as cesium, strontium etc.) from low level radioactive effluents, alkali metal ion -H' exchanges on nine indigenous gel- and macroporous-type and nuclear grade resins have been studied at a total ionic strength of 0.1 mol dm .3 (in the case ofCs' -H' exchange it was 0.05 mol dm .3 ). The expected theoretical capacities were not attained by all the resins for the alkali metal ions. The water content (moles/equiv.) of the fully swollen resins for different alkali metal ionic forms do not follow the usual sequence of greater the tendency of the cation to hydrate the higher the water uptake, but a reverse trend. The ion exchange isotherms (plots of equivalent fractions of the ion in resin phase, N M1 to that in solution, N M ) were not satisfactory and sorption of cations, for most of the resins, was possible only when the acidity of the solution was lowered. The variations of the selectivity coefficient, K, with N M show that the resins are highly cross linked and the selectivity sequence: Cs + >K + >Na + >Li + , obtained for all the resins indicate that hydrated ions were involved in the exchange process. However, the increase in the selectivity was not accompanied by the release of water, but unusual uptake of water, during the exchange process. The characteristics of macroporous resins were not significantly different from those of the gel-type resins. The results are discussed in terms of heterogeneity in the polymer net work, improper sulphonation process resulting in the formation of functional groups at inaccessible sites with weak acidic character and the overall lack of control in the preparation of different resins. (author)

  8. Maximizing Ion Current by Space Charge Neutralization using Negative Ions and Dust Particles

    International Nuclear Information System (INIS)

    Smirnov, A.; Raitses, Y.; Fisch, N.J.

    2005-01-01

    Ion current extracted from an ion source (ion thruster) can be increased above the Child-Langmuir limit if the ion space charge is neutralized. Similarly, the limiting kinetic energy density of the plasma flow in a Hall thruster might be exceeded if additional mechanisms of space charge neutralization are introduced. Space charge neutralization with high-mass negative ions or negatively charged dust particles seems, in principle, promising for the development of a high current or high energy density source of positive light ions. Several space charge neutralization schemes that employ heavy negatively charged particles are considered. It is shown that the proposed neutralization schemes can lead, at best, only to a moderate but nonetheless possibly important increase of the ion current in the ion thruster and the thrust density in the Hall thruster

  9. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1982-01-01

    Ion-Selective Electrode Reviews, Volume 3, provides a review of articles on ion-selective electrodes (ISEs). The volume begins with an article on methods based on titration procedures for surfactant analysis, which have been developed for discrete batch operation and for continuous AutoAnalyser use. Separate chapters deal with detection limits of ion-selective electrodes; the possibility of using inorganic ion-exchange materials as ion-sensors; and the effect of solvent on potentials of cells with ion-selective electrodes. Also included is a chapter on advances in calibration procedures, the d

  10. An all permanent magnet electron cyclotron resonance ion source for heavy ion therapy.

    Science.gov (United States)

    Cao, Yun; Li, Jia Qing; Sun, Liang Ting; Zhang, Xue Zhen; Feng, Yu Cheng; Wang, Hui; Ma, Bao Hua; Li, Xi Xia

    2014-02-01

    A high charge state all permanent Electron Cyclotron Resonance ion source, Lanzhou All Permanent ECR ion source no. 3-LAPECR3, has been successfully built at IMP in 2012, which will serve as the ion injector of the Heavy Ion Medical Machine (HIMM) project. As a commercial device, LAPECR3 features a compact structure, small size, and low cost. According to HIMM scenario more than 100 eμA of C(5+) ion beam should be extracted from the ion source, and the beam emittance better than 75 π*mm*mrad. In recent commissioning, about 120 eμA of C(5+) ion beam was got when work gas was CH4 while about 262 eμA of C(5+) ion beam was obtained when work gas was C2H2 gas. The design and construction of the ion source and its low-energy transportation beam line, and the preliminary commissioning results will be presented in detail in this paper.

  11. Nonlinear dust-ion-acoustic waves in a multi-ion plasma with ...

    Indian Academy of Sciences (India)

    The basic features of such dust-ion-acoustic solitary and shock waves have been ... ion plasmas because of its vital role in understanding different types of ... cannot support the usual ion-acoustic waves, but can support the DIA waves of ...

  12. Low energy ion beam dynamics of NANOGAN ECR ion source

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Sarvesh, E-mail: sarvesh@iuac.res.in; Mandal, A.

    2016-04-01

    A new low energy ion beam facility (LEIBF) has been developed for providing the mass analyzed highly charged intense ion beams of energy ranging from a few tens of keV to a few MeV for atomic, molecular and materials sciences research. The new facility consists of an all permanent magnet 10 GHz electron cyclotron resonance (ECR) ion source (NANOGAN) installed on a high voltage platform (400 kV) which provides large currents of multiply charged ion beams. Higher emittance at low energy of intense ion beam puts a tremendous challenge to the beam optical design of this facility. The beam line consists of mainly the electrostatic quadrupoles, an accelerating section, analyzing cum switching magnet and suitable beam diagnostics including vacuum components. The accelerated ion beam is analyzed for a particular mass to charge (m/q) ratio as well as guided to three different lines along 75°, 90° and 105° using a large acceptance analyzing cum switching magnet. The details of transverse beam optics to all the beam lines with TRANSPORT and GICOSY beam optics codes are being described. Field computation code, OPERA 3D has been utilized to design the magnets and electrostatic quadrupoles. A theoretical estimation of emittance for optimized geometry of ion source is given so as to form the basis of beam optics calculations. The method of quadrupole scan of the beam is used to characterize the emittance of the final beam on the target. The measured beam emittance increases with m/q ratios of various ion beams similar to the trend observed theoretically.

  13. Radioactive ion beam production challenges at the Holifield Heavy Ion Research Facility

    International Nuclear Information System (INIS)

    Meigs, M.J.; Alton, G.D.; Dowling, D.T.; Haynes, D.L.; Jones, C.M.; Juras, R.C.; Lane, S.N.; Mills, G.D.; Mosko, S.W.; Olsen, D.K.; Tatum, B.A.

    1992-01-01

    The radioactive ion beam (RIB) project at the Holifield Heavy Ion Research Facility (HHIRF) will provide for reconfiguration of the HHIRF accelerator system to enable provision of low-intensity RIBs for nuclear and astrophysics research. As we have progressed with the design of the reconfiguration, we have encountered several challenges that were not immediately obvious when first contemplating the project. The challenges do not seem insurmountable but should keep life interesting for those of us doing the work. A brief review of the project will allow a better understanding of the challenges in RIB production. Radioactive ion beams will be produced with the Isotope Separator On-Line (ISOL) postacceleration technique. In particular, radioactive atoms will be produced by reactions in the thick stopping target of an ISOL-type target-ion source assembly using intense beams from the Oak Ridge Isochronous Cyclotron equipped with a light-ion internal source. This ISOL target-ion source assembly will be mounted on a high-voltage platform with a mass separator. The target ion source will operate at potentials up to 50 kV with respect to the high voltage platform. The radioactive atoms produced by nuclear reactions in the target diffuse to the surface of the heated target material, desorb from this surface, and effuse through a heated transfer tube into an ion source where ionization and extraction take place. Two types of ion sources will be initially considered. A Forced Electron Beam Induced Arc Discharge source, similar to those used by the ISOLDE facility at CERN and by the UNISOR facility at ORNL, will be built to produce positive ions. These positive ions will be focused through an alkali vapor charge-exchange canal to produce negative ions for tandem injection. In addition, a direct negative surface ionization addition or modification to the above source will be built and investigated

  14. Improvement of highly charged ion production in the ECR source of heavy ions

    International Nuclear Information System (INIS)

    Shirkov, G.D.

    1996-01-01

    Some physical limitations of the highly charged ion production in the ECR source are analyzed in this report. A few possible ways to improve the output of highly charged ions from the ECR source for heavy ions are proposed. A new library of computer codes for the numerical simulation of heavy ion production in the ECR ion source is used to examine these ways to improve the ECR source operation according to the CERN program of heavy ion acceleration. copyright 1996 American Institute of Physics

  15. Comparison Of The MWCNTs-Rh And MWCNTs-Re Carbon-Metal Nanocomposites Obtained In High-Temperature

    Directory of Open Access Journals (Sweden)

    Dobrzańska-Danikiewicz A.D.

    2015-09-01

    Full Text Available Carbon-metal nanocomposites consisting of multiwalled carbon nanotubes coated with rhodium or rhenium nanoparticles by the high-temperature method were fabricated during the research undertaken. Multiwalled carbon nanotubes fabricated by Catalytic-Chemical Vapour Deposition (CCVD were used in the investigations. Multiwalled carbon nanotubes functionalisation in acid or in a mixture of acids was applied to deposit rhodium or rhenium nanoparticles onto the surface of carbon nanotubes, and then the material was placed in a solution being a precursor of metallic nanoparticles. The material prepared was next subjected to high-temperature reduction in the atmosphere of argon and/or hydrogen to deposit rhodium or rhenium nanoparticles onto the surface of multiwalled carbon nanotubes. The investigations performed include, respectively: fabrication of a CNT-NPs (Carbon NanoTube-NanoParticles nanocomposite material; the characterisation of the material produced including examination of the structure and morphology, and the assessment of rhodium and/or rhenium nanoparticles distribution on the surface of carbon nanotubes. Micro- and spectroscopy techniques were employed to characterise the structure of the nanocomposites obtained.

  16. Plasma focus as an heavy ion source in the problem of heavy ion fusion

    International Nuclear Information System (INIS)

    Gribkov, V.A.; Dubrovskij, A.V.; Kalachev, N.V.; Krokhin, O.N.; Silin, P.V.; Nikulin, V.Ya.; Cheblukov, Yu.N.

    1984-01-01

    Results of experiments on the ion flux formation in a plasma focus (PF) to develop a multicharged ion source for thermonuclear facility driver are presented. In plasma focus accelerating section copper ions were injected. Advantages of the suggested method of ion beam formation are demonstrated. Beam emittance equalling < 0.1 cmxmrad is obtained. Plasma focus ion energy exceeds 1 MeV. Plasma focus in combination with a neodymium laser is thought to be a perspective ion source for heavy ion fusion

  17. Ion-ion and ion-solvent interactions in lithium imidazolide electrolytes studied by Raman spectroscopy and DFT models.

    Science.gov (United States)

    Scheers, Johan; Niedzicki, Leszek; Zukowska, Grażyna Z; Johansson, Patrik; Wieczorek, Władysław; Jacobsson, Per

    2011-06-21

    Molecular level interactions are of crucial importance for the transport properties and overall performance of ion conducting electrolytes. In this work we explore ion-ion and ion-solvent interactions in liquid and solid polymer electrolytes of lithium 4,5-dicyano-(2-trifluoromethyl)imidazolide (LiTDI)-a promising salt for lithium battery applications-using Raman spectroscopy and density functional theory calculations. High concentrations of ion associates are found in LiTDI:acetonitrile electrolytes, the vibrational signatures of which are transferable to PEO-based LiTDI electrolytes. The origins of the spectroscopic changes are interpreted by comparing experimental spectra with simulated Raman spectra of model structures. Simple ion pair models in vacuum identify the imidazole nitrogen atom of the TDI anion to be the most important coordination site for Li(+), however, including implicit or explicit solvent effects lead to qualitative changes in the coordination geometry and improved correlation of experimental and simulated Raman spectra. To model larger aggregates, solvent effects are found to be crucial, and we finally suggest possible triplet and dimer ionic structures in the investigated electrolytes. In addition, the effects of introducing water into the electrolytes-via a hydrate form of LiTDI-are discussed.

  18. Experiments on secondary ion emission with multicharged keV ion bombardement

    International Nuclear Information System (INIS)

    Della Negra, S.; Depauw, J.; Joret, H.; Le Beyec, Y.; Schweikert, E.A.

    1987-01-01

    An electron cyclotron resonance ion source was used to study the influence of the incident charge state of keV ions on secondary ion emission. The experiments were run with 18 keV Arn+ (1 < n < 11) beams produced by a minimafios source. Various types of targets were bombarded by the ion beam and the sputtered ionized species were identified by time of flight mass spectrometry. The experimental arrangement is detailed and preliminary results are indicated

  19. A heating mechanism of ions due to large amplitude coherent ion acoustic wave

    International Nuclear Information System (INIS)

    Yajima, Nobuo; Kawai, Yoshinobu; Kogiso, Ken.

    1978-05-01

    Ion heating mechanism in a plasma with a coherent ion acoustic wave is studied experimentally and numerically. Ions are accelerated periodically in the electrostatic potential of the coherent wave and their oscillation energy is converted into the thermal energy of ions through the collision with the neutral atoms in plasma. The Monte Carlo calculation is applied to obtain the ion temperature. The amplitude of the electrostatic potential, the mean number of collisions and the mean life time of ions are treated as parameters in the calculation. The numerical results are compared with the experiments and both of them agree well. It is found that the ion temperature increases as the amplitude of the coherent wave increases and the high energy tail in the distribution function of ions are observed for the case of large wave-amplitude. (author)

  20. Molecular and negative ion production by a standard electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Racz, R. [Institute of Nuclear Research (ATOMKI), Bem ter 18/c, H-4026 Debrecen (Hungary); University of Debrecen, Egyetem ter 1, H-4010 Debrecen (Hungary); Biri, S.; Juhasz, Z.; Sulik, B. [Institute of Nuclear Research (ATOMKI), Bem ter 18/c, H-4026 Debrecen (Hungary); Palinkas, J. [University of Debrecen, Egyetem ter 1, H-4010 Debrecen (Hungary)

    2012-02-15

    Molecular and negative ion beams, usually produced in special ion sources, play an increasingly important role in fundamental and applied atomic physics. The ATOMKI-ECRIS is a standard ECR ion source, designed to provide highly charged ion (HCI) plasmas and beams. In the present work, H{sup -}, O{sup -}, OH{sup -}, O{sub 2}{sup -}, C{sup -}, C{sub 60}{sup -} negative ions and H{sub 2}{sup +}, H{sub 3}{sup +}, OH{sup +}, H{sub 2}O{sup +}, H{sub 3}O{sup +}, O{sub 2}{sup +} positive molecular ions were generated in this HCI-ECRIS. Without any major modification in the source and without any commonly applied tricks (such as usage of cesium or magnetic filter), negative ion beams of several {mu}A and positive molecular ion beams in the mA range were successfully obtained.

  1. Ion hole formation and nonlinear generation of electromagnetic ion cyclotron waves: THEMIS observations

    Science.gov (United States)

    Shoji, Masafumi; Miyoshi, Yoshizumi; Katoh, Yuto; Keika, Kunihiro; Angelopoulos, Vassilis; Kasahara, Satoshi; Asamura, Kazushi; Nakamura, Satoko; Omura, Yoshiharu

    2017-09-01

    Electromagnetic plasma waves are thought to be responsible for energy exchange between charged particles in space plasmas. Such an energy exchange process is evidenced by phase space holes identified in the ion distribution function and measurements of the dot product of the plasma wave electric field and the ion velocity. We develop a method to identify ion hole formation, taking into consideration the phase differences between the gyromotion of ions and the electromagnetic ion cyclotron (EMIC) waves. Using this method, we identify ion holes in the distribution function and the resulting nonlinear EMIC wave evolution from Time History of Events and Macroscale Interactions during Substorms (THEMIS) observations. These ion holes are key to wave growth and frequency drift by the ion currents through nonlinear wave-particle interactions, which are identified by a computer simulation in this study.

  2. Ion Dynamics at Shocks: Ion Reflection and Beam Formation at Quasi-perpendicular Shocks

    International Nuclear Information System (INIS)

    Kucharek, Harald; Moebius, Eberhard

    2005-01-01

    The physics of collisionless shocks is controlled by the ion dynamics. The generation of gyrating ions by reflection as well as the formation of field-aligned ion beams are essential parts of this dynamic. On the one hand reflection is most likely the first interaction of ions with the shock before they undergo the downstream thermalization process. On the other hand field-aligned ion beams, predominately found at the quasi-perpendicular bow shock, propagate into the distant foreshock region and may create wave activity. We revisit ion reflection, the source and basic production mechanism of field-aligned ion beams, by using multi-spacecraft measurements and contrast these observations with existing theories. Finally, we propose an alternative production mechanism

  3. Generation and focusing of intense ion beams with an inverse pinch ion diode

    International Nuclear Information System (INIS)

    Hashimoto, Yoshiyuki; Sato, Morihiko; Yatsuzuka, Mitsuyasu; Nobuhara, Sadao

    1992-01-01

    Generation and focusing of ion beams using an inverse pinch ion diode with a flat anode has been studied. The ion beams generated with the inverse pinch ion diode were found to be focused at 120 mm from the anode by the electrostatic field in the diode. The energy and maximum current density of the ion beams were 180 keV and 420 A/cm 2 , respectively. The focusing angle of the ion beams was 4.3deg. The beam brightness was estimated to be 1.3 GW/cm 2 ·rad 2 . The focusing distance of the ion beams was found to be controllable by changing the diameters of the anode and cathode. (author)

  4. Behaviour of tetraalkylammonium ions in high-field asymmetric waveform ion mobility spectrometry.

    Science.gov (United States)

    Aksenov, Alexander A; Kapron, James T

    2010-05-30

    High-field asymmetric waveform ion mobility spectrometry (FAIMS) is an ion-filtering technique recently adapted for use with liquid chromatography/mass spectrometry (LC/MS) to remove interferences during analysis of complex matrices. This is the first systematic study of a series of singly charged tetraalkylammonium ions by FAIMS-MS. The compensation voltage (CV) is the DC offset of the waveform which permits the ion to emerge from FAIMS and it was determined for each member of the series under various conditions. The electrospray ionization conditions explored included spray voltage, vaporizer temperature, and sheath and auxiliary gas pressure. The FAIMS conditions explored included carrier gas flow rate, electrode temperature and composition of the carrier gas. Optimum desolvation was achieved using sufficient carrier gas (flow rate > or = 2 L/min) to ensure stable response. Low-mass ions (m/z 100-200) are more susceptible to changes in electrode temperature and gas composition than high mass ions (m/z 200-700). As a result of this study, ions are reliably analyzed using standard FAIMS conditions (dispersion voltage -5000 V, carrier gas flow rate 3 L/min, 50% helium/50%nitrogen, inner electrode temperature 70 degrees C and outer electrode temperature 90 degrees C). Variation of FAIMS conditions may be of great use for the separation of very low mass tetraalkylammonium (TAA) ions from other TAA ions. The FAIMS conditions do not appear to have a major effect on higher mass ions. Copyright 2010 John Wiley & Sons, Ltd.

  5. Specific ion effects on membrane potential and the permselectivity of ion exchange membranes

    KAUST Repository

    Geise, Geoffrey M.

    2014-08-26

    © the Partner Organisations 2014. Membrane potential and permselectivity are critical parameters for a variety of electrochemically-driven separation and energy technologies. An electric potential is developed when a membrane separates electrolyte solutions of different concentrations, and a permselective membrane allows specific species to be transported while restricting the passage of other species. Ion exchange membranes are commonly used in applications that require advanced ionic electrolytes and span technologies such as alkaline batteries to ammonium bicarbonate reverse electrodialysis, but membranes are often only characterized in sodium chloride solutions. Our goal in this work was to better understand membrane behaviour in aqueous ammonium bicarbonate, which is of interest for closed-loop energy generation processes. Here we characterized the permselectivity of four commercial ion exchange membranes in aqueous solutions of sodium chloride, ammonium chloride, sodium bicarbonate, and ammonium bicarbonate. This stepwise approach, using four different ions in aqueous solution, was used to better understand how these specific ions affect ion transport in ion exchange membranes. Characterization of cation and anion exchange membrane permselectivity, using these ions, is discussed from the perspective of the difference in the physical chemistry of the hydrated ions, along with an accompanying re-derivation and examination of the basic equations that describe membrane potential. In general, permselectivity was highest in sodium chloride and lowest in ammonium bicarbonate solutions, and the nature of both the counter- and co-ions appeared to influence measured permselectivity. The counter-ion type influences the binding affinity between counter-ions and polymer fixed charge groups, and higher binding affinity between fixed charge sites and counter-ions within the membrane decreases the effective membrane charge density. As a result permselectivity decreases. The

  6. Observations of strong ion-ion correlations in dense plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Ma, T.; Fletcher, L.; Pak, A.; Chapman, D. A.; Falcone, R. W.; Fortmann, C.; Galtier, E.; Gericke, D. O.; Gregori, G.; Hastings, J.; Landen, O. L.; Le Pape, S.; Lee, H. J.; Nagler, B.; Neumayer, P.; Turnbull, D.; Vorberger, J.; White, T. G.; Wünsch, K.; Zastrau, U.; Glenzer, S. H.; Döppner, T.

    2014-05-01

    Using simultaneous spectrally, angularly, and temporally resolved x-ray scattering, we measure the pronounced ion-ion correlation peak in a strongly coupled plasma. Laser-driven shock-compressed aluminum at ~3× solid density is probed with high-energy photons at 17.9 keV created by molybdenum He-α emission in a laser-driven plasma source. The measured elastic scattering feature shows a well-pronounced correlation peak at a wave vector of k=4k=4Å-1. The magnitude of this correlation peak cannot be described by standard plasma theories employing a linear screened Coulomb potential. Advanced models, including a strong short-range repulsion due to the inner structure of the aluminum ions are however in good agreement with the scattering data. These studies have demonstrated a new highly accurate diagnostic technique to directly measure the state of compression and the ion-ion correlations. We have since applied this new method in single-shot wave-number resolved S(k) measurements to characterize the physical properties of dense plasmas.

  7. Hierarchical architecture of ReS{sub 2}/rGO composites with enhanced electrochemical properties for lithium-ion batteries

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Fei; Chen, Yuanfu, E-mail: yfchen@uestc.edu.cn; Zheng, Binjie; He, Jiarui; Li, Qian; Wang, Xinqiang; Lin, Jie; Zhou, Jinhao; Yu, Bo; Li, Pingjian; Zhang, Wanli

    2017-08-15

    Highlights: • The ReS{sub 2}/rGO composites have been synthesized by a facile one-pot method. • The ReS{sub 2}/rGO composites exhibit hierarchical architecture. • The ReS{sub 2}/rGO composites deliver better electrochemical performances than ReS{sub 2}. • The enhanced performance is due to porous and conductive structure of ReS{sub 2}/rGO. - Abstract: Rhenium disulfide (ReS{sub 2}), a two-dimensional (2D) semiconductor, has attracted more and more attention due to its unique anisotropic electronic, optical, mechanical properties. However, the facile synthesis and electrochemical property of ReS{sub 2} and its composite are still necessary to be researched. In this study, for the first time, the ReS{sub 2}/reduced graphene oxide (rGO) composites have been synthesized through a facile and one-pot hydrothermal method. The ReS{sub 2}/rGO composites exhibit a hierarchical, interconnected, and porous architecture constructed by nanosheets. As anode for lithium-ion batteries, the as-synthesized ReS{sub 2}/rGO composites deliver a large initial capacity of 918 mAh g{sup −1} at 0.2 C. In addition, the ReS{sub 2}/rGO composites exhibit much better electrochemical cycling stability and rate capability than that of bare ReS{sub 2}. The significant enhancement in electrochemical property can be attributed to its unique architecture constructed by nanosheets and porous structure, which can allow for easy electrolyte infiltration, efficient electron transfer, and ionic diffusion. Furthermore, the graphene with high electronic conductivity can provide good conductive passageways. The facile synthesis approach can be extended to prepare other 2D transition metal dichalcogenides semiconductors for energy storage and catalytic application.

  8. Growth and structure of titanium dioxide on the transition metal surfaces Re(10-10) and Ru(0001); Wachstum und Struktur von Titandioxid auf den Uebergangsmetalloberflaechen Re(10-10) und Ru(0001)

    Energy Technology Data Exchange (ETDEWEB)

    Rosenthal, D.

    2007-03-15

    In this work, we studied the growth and structure of titanium dioxide films on two morphologically different transition metal surfaces, namely the trench-like rhenium(10-10) and the hexagonal ruthenium(0001). The following methods were used: X-ray photoelectron and Auger-electron spectroscopy (XPS and AES), low energy electron diffraction (LEED), low energy Helium-ion scattering (LEIS), scanning tunneling microscopy (STM) and X-ray diffraction (XRD). Titanium dioxide films on rhenium(10-10) were synthesized by co-adsorption of titanium vapor in an oxygen atmosphere up to a thickness of 500 Aa and investigated by means of LEED, LEIS, XPS and XRD. In order to calibrate the titanium flux, the growth mode of titanium on the Re(10-10) surface was determined by means of LEIS, XPS and LEED. The growth of titanium dioxide on the hexagonal ruthenium(0001) surface was investigated by means of STM, XPS and AES. Due to the alloying affinity of Ti and Ru, a titanium oxide film pre-grown at low temperature was finally/fully oxidized at elevated temperature and pressure. First experiments concerning the growth of gold on these titanium dioxide films are presented. One important result of the ongoing work is the imaging of gold clusters with 2-5 atoms in the troughs of rutile(110) beside the typically observed clusters with 3 nm diameter by STM. (orig.)

  9. New experimental initiatives using very highly charged ions from an 'electron beam ion trap'

    International Nuclear Information System (INIS)

    Schneider, D.

    1996-01-01

    A short review of the experimental program in highly-charged heavy ion physics conducted at the Lawrence Livermore National Laboratory Electron Beam Ion Trap (EBIT) facility is presented. The heavy-ion research, involving ions up to fully stripped U 92+ , includes precision x-ray spectroscopy and lifetime studies, electron impact ionization and excitation cross section measurements. The investigations of ion-surface interactions following the impact of high-Z highly charged ions on surfaces are aimed to study the neutralization dynamics effecting the ion and the response of the surface as well. (author)

  10. Development of exploding wire ion source for intense pulsed heavy ion beam accelerator

    International Nuclear Information System (INIS)

    Ochiai, Y.; Murata, T.; Ito, H.; Masugata, K.

    2012-01-01

    A Novel exploding wire type ion source device is proposed as a metallic ion source of intense pulsed heavy ion beam (PHIB) accelerator. In the device multiple shot operations is realized without breaking the vacuum. The basic characteristics of the device are evaluated experimentally with an aluminum wire of diameter 0.2 mm, length 25 mm. Capacitor bank of capacitance 3 μF, charging voltage 30 kV was used and the wire was successfully exploded by a discharge current of 15 kA, rise time 5.3 μs. Plasma flux of ion current density around 70 A/cm 2 was obtained at 150 mm downstream from the device. The drift velocity of ions evaluated by a time-of-flight method was 2.7x10 4 m/sec, which corresponds to the kinetic energy of 100 eV for aluminum ions. From the measurement of ion current density distribution ion flow is found to be concentrated to the direction where ion acceleration gap is placed. From the experiment the device is found to be acceptable for applying PHIB accelerator. (author)

  11. An all permanent magnet electron cyclotron resonance ion source for heavy ion therapy

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Yun, E-mail: caoyun@impcas.ac.cn; Li, Jia Qing; Sun, Liang Ting; Zhang, Xue Zhen; Feng, Yu Cheng; Wang, Hui; Ma, Bao Hua; Li, Xi Xia [Institute of Modern Physics, CAS, Lanzhou 730000 (China)

    2014-02-15

    A high charge state all permanent Electron Cyclotron Resonance ion source, Lanzhou All Permanent ECR ion source no. 3-LAPECR3, has been successfully built at IMP in 2012, which will serve as the ion injector of the Heavy Ion Medical Machine (HIMM) project. As a commercial device, LAPECR3 features a compact structure, small size, and low cost. According to HIMM scenario more than 100 eμA of C{sup 5+} ion beam should be extracted from the ion source, and the beam emittance better than 75 π*mm*mrad. In recent commissioning, about 120 eμA of C{sup 5+} ion beam was got when work gas was CH{sub 4} while about 262 eμA of C{sup 5+} ion beam was obtained when work gas was C{sub 2}H{sub 2} gas. The design and construction of the ion source and its low-energy transportation beam line, and the preliminary commissioning results will be presented in detail in this paper.

  12. Recent advances in high current vacuum arc ion sources for heavy ion fusion

    CERN Document Server

    Qi Nian Sheng; Prasad, R R; Krishnan, M S; Anders, A; Kwan, J; Brown, I

    2001-01-01

    For a heavy ion fusion induction linac driver, a source of heavy ions with charge states 1+-3+, approx 0.5 A current beams, approx 20 mu s pulse widths and approx 10 Hz repetition rates is required. Thermionic sources have been the workhorse for the Heavy Ion Fusion (HIF) program to date, but suffer from heating problems for large areas and contamination. They are limited to low (contact) ionization potential elements and offer relatively low ion fluxes with a charge state limited to 1+. Gas injection sources suffer from partial ionization and deleterious neutral gas effects. The above shortcomings of the thermionic ion sources can be overcome by a vacuum arc ion source. The vacuum arc ion source is a good candidate for HIF applications. It is capable of providing ions of various elements and different charge states in short and long pulse bursts and high beam current density. Under a Phase-I STTR from DOE, the feasibility of the vacuum arc ion source for the HIF applications was investigated. We have modifie...

  13. Anomalous surface behavior of hydrated guanidinium ions due to ion pairing

    Science.gov (United States)

    Ekholm, Victor; Vazdar, Mario; Mason, Philip E.; Bialik, Erik; Walz, Marie-Madeleine; Öhrwall, Gunnar; Werner, Josephina; Rubensson, Jan-Erik; Jungwirth, Pavel; Björneholm, Olle

    2018-04-01

    Surface affinity of aqueous guanidinium chloride (GdmCl) is compared to that of aqueous tetrapropylammonium chloride (TPACl) upon addition of sodium chloride (NaCl) or disodium sulfate (Na2SO4). The experimental results have been acquired using the surface sensitive technique X-ray photoelectron spectroscopy on a liquid jet. Molecular dynamics simulations have been used to produce radial distribution functions and surface density plots. The surface affinities of both TPA+ and Gdm+ increase upon adding NaCl to the solution. With the addition of Na2SO4, the surface affinity of TPA+ increases, while that of Gdm+ decreases. From the results of MD simulations it is seen that Gdm+ and SO4 2 - ions form pairs. This finding can be used to explain the decreased surface affinity of Gdm+ when co-dissolved with SO4 2 - ions. Since SO4 2 - ions avoid the surface due to the double charge and strong water interaction, the Gdm+-SO4 2 - ion pair resides deeper in the solutions' bulk than the Gdm+ ions. Since TPA+ does not form ion pairs with SO4 2 -, the TPA+ ions are instead enriched at the surface.

  14. Energy landscapes for mobile ions in ion conducting solids

    Indian Academy of Sciences (India)

    molecular dynamics (MD) simulations yields quantitative predictions of the ion transport characteristics. As ... Solid electrolytes; bond valence analysis; ion transport in glasses. 1. .... clusters are considered to contribute only to a.c. conduc-.

  15. Effects of pancreatic intraductal injection of a radioisotope in dogs

    International Nuclear Information System (INIS)

    Devonec, M.; Faure, J.L.; Blanc-Brunat, N.; Dubernard, J.M.; Traeger, J.

    1980-01-01

    The effects on exocrine and endocrine pancreatic functions of local irradiation by the intraductal injection of Rhenium 186 were investigated as an alternative to neoprene for exocrine secretion suppression. The results indicate that Rhenium 186 irradiation suppressed exocrine secretion of the pancreas while conserving the endocrine function. Although some edema and fibrosis were observed, the effects were not excessive

  16. DETERMINATION OF STRONTIUM IONS IN WATERS WITH A HIGH CONTENT OF SODIUM IONS

    Directory of Open Access Journals (Sweden)

    Tatiana Mitina

    2015-06-01

    Full Text Available This paper reports on the influence of sodium ions on experimental determination of strontium ions concentration in waters with a high content of sodium ions by using emission flame photometry and atomic absorption spectroscopy. For the method of emission flame photometry it was shown that at a wavelength of 460.7 nm (spectral emission line of strontium the emission is linearly dependent on the concentration of sodium ions. The greatest impact of high concentrations of sodium ions on the result of determination the strontium ions concentration has been registered at low levels of strontium. The influence of nitric acid on the results is also discussed. In the case of using atomic absorption spectroscopy method no influence of sodium ions and nitric acid on the results of determination the strontium ions concentration was revealed. The metrological characteristics of both methods are evaluated.

  17. An ion beam deceleration lens for ultra-low-energy ion bombardment of naked DNA

    Energy Technology Data Exchange (ETDEWEB)

    Thopan, P.; Prakrajang, K. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thongkumkoon, P. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand); Suwannakachorn, D. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Yu, L.D., E-mail: yuldyuld@gmail.com [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand)

    2013-07-15

    Highlights: ► An ion beam deceleration lens was designed and constructed. ► The deceleration lens was installed and tested. ► The decelerated ion beam energy was measured using an electrical field. ► Decelerated ultra-low-energy ion beam bombarded naked DNA. ► Ion beam with energy of a few tens of eV could break DNA strands. -- Abstract: Study of low-energy ion bombardment effect on biological living materials is of significance. High-energy ion beam irradiation of biological materials such as organs and cells has no doubt biological effects. However, ion energy deposition in the ion-bombarded materials dominantly occurs in the low-energy range. To investigate effects from very-low-energy ion bombardment on biological materials, an ion beam deceleration lens is necessary for uniform ion energy lower than keV. A deceleration lens was designed and constructed based on study of the beam optics using the SIMION program. The lens consisted of six electrodes, able to focus and decelerate primary ion beam, with the last one being a long tube to obtain a parallel uniform exiting beam. The deceleration lens was installed to our 30-kV bioengineering-specialized ion beam line. The final decelerated-ion energy was measured using a simple electrostatic field to bend the beam to range from 10 eV to 1 keV controlled by the lens parameters and the primary beam condition. In a preliminary test, nitrogen ion beam at 60 eV decelerated from a primary 20-keV beam bombarded naked plasmid DNA. The original DNA supercoiled form was found to change to relaxed and linear forms, indicating single or double strand breaks. The study demonstrated that the ion bombardment with energy as low as several-tens eV was possible to break DNA strands and thus potential to cause genetic modification of biological cells.

  18. An ion beam deceleration lens for ultra-low-energy ion bombardment of naked DNA

    International Nuclear Information System (INIS)

    Thopan, P.; Prakrajang, K.; Thongkumkoon, P.; Suwannakachorn, D.; Yu, L.D.

    2013-01-01

    Highlights: ► An ion beam deceleration lens was designed and constructed. ► The deceleration lens was installed and tested. ► The decelerated ion beam energy was measured using an electrical field. ► Decelerated ultra-low-energy ion beam bombarded naked DNA. ► Ion beam with energy of a few tens of eV could break DNA strands. -- Abstract: Study of low-energy ion bombardment effect on biological living materials is of significance. High-energy ion beam irradiation of biological materials such as organs and cells has no doubt biological effects. However, ion energy deposition in the ion-bombarded materials dominantly occurs in the low-energy range. To investigate effects from very-low-energy ion bombardment on biological materials, an ion beam deceleration lens is necessary for uniform ion energy lower than keV. A deceleration lens was designed and constructed based on study of the beam optics using the SIMION program. The lens consisted of six electrodes, able to focus and decelerate primary ion beam, with the last one being a long tube to obtain a parallel uniform exiting beam. The deceleration lens was installed to our 30-kV bioengineering-specialized ion beam line. The final decelerated-ion energy was measured using a simple electrostatic field to bend the beam to range from 10 eV to 1 keV controlled by the lens parameters and the primary beam condition. In a preliminary test, nitrogen ion beam at 60 eV decelerated from a primary 20-keV beam bombarded naked plasmid DNA. The original DNA supercoiled form was found to change to relaxed and linear forms, indicating single or double strand breaks. The study demonstrated that the ion bombardment with energy as low as several-tens eV was possible to break DNA strands and thus potential to cause genetic modification of biological cells

  19. Pulsed, Inductively Generated, Streaming Plasma Ion Source for Heavy Ion Fusion Linacs

    International Nuclear Information System (INIS)

    Steven C. Glidden; Howard D Sanders; John B. Greenly; Daniel L. Dongwoo

    2006-01-01

    This report describes a compact, high current density, pulsed ion source, based on electrodeless, inductively driven gas breakdown, developed to meet the requirements on normalized emittance, current density, uniformity and pulse duration for an ion injector in a heavy-ion fusion driver. The plasma source produces >10 (micro)s pulse of Argon plasma with ion current densities >100 mA/cm2 at 30 cm from the source and with strongly axially directed ion energy of about 80 eV, and sub-eV transverse temperature. The source has good reproducibility and spatial uniformity. Control of the current density during the pulse has been demonstrated with a novel modulator coil method which allows attenuation of the ion current density without significantly affecting the beam quality. This project was carried out in two phases. Phase 1 used source configurations adapted from light ion sources to demonstrate the feasibility of the concept. In Phase 2 the performance of the source was enhanced and quantified in greater detail, a modulator for controlling the pulse shape was developed, and experiments were conducted with the ions accelerated to >40 kV

  20. A model for the oceanic mass balance of rhenium and implications for the extent of Proterozoic ocean anoxia

    Science.gov (United States)

    Sheen, Alex I.; Kendall, Brian; Reinhard, Christopher T.; Creaser, Robert A.; Lyons, Timothy W.; Bekker, Andrey; Poulton, Simon W.; Anbar, Ariel D.

    2018-04-01

    Emerging geochemical evidence suggests that the atmosphere-ocean system underwent a significant decrease in O2 content following the Great Oxidation Event (GOE), leading to a mid-Proterozoic ocean (ca. 2.0-0.8 Ga) with oxygenated surface waters and predominantly anoxic deep waters. The extent of mid-Proterozoic seafloor anoxia has been recently estimated using mass-balance models based on molybdenum (Mo), uranium (U), and chromium (Cr) enrichments in organic-rich mudrocks (ORM). Here, we use a temporal compilation of concentrations for the redox-sensitive trace metal rhenium (Re) in ORM to provide an independent constraint on the global extent of mid-Proterozoic ocean anoxia and as a tool for more generally exploring how the marine geochemical cycle of Re has changed through time. The compilation reveals that mid-Proterozoic ORM are dominated by low Re concentrations that overall are only mildly higher than those of Archean ORM and significantly lower than many ORM deposited during the ca. 2.22-2.06 Ga Lomagundi Event and during the Phanerozoic Eon. These temporal trends are consistent with a decrease in the oceanic Re inventory in response to an expansion of anoxia after an interval of increased oxygenation during the Lomagundi Event. Mass-balance modeling of the marine Re geochemical cycle indicates that the mid-Proterozoic ORM with low Re enrichments are consistent with extensive seafloor anoxia. Beyond this agreement, these new data bring added value because Re, like the other metals, responds generally to low-oxygen conditions but has its own distinct sensitivity to the varying environmental controls. Thus, we can broaden our capacity to infer nuanced spatiotemporal patterns in ancient redox landscapes. For example, despite the still small number of data, some mid-Proterozoic ORM units have higher Re enrichments that may reflect a larger oceanic Re inventory during transient episodes of ocean oxygenation. An improved understanding of the modern oceanic Re

  1. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1985-01-01

    Ion-Selective Electrode Reviews, Volume 7 is a collection of papers that covers the applications of electrochemical sensors, along with the versatility of ion-selective electrodes. The coverage of the text includes solid contact in membrane ion-selective electrodes; immobilized enzyme probes for determining inhibitors; potentiometric titrations based on ion-pair formation; and application of ion-selective electrodes in soil science, kinetics, and kinetic analysis. The text will be of great use to chemists and chemical engineers.

  2. Observation of ion-acoustic rarefaction solitons in a multicomponent plasma with negative ions

    International Nuclear Information System (INIS)

    Ludwig, G.O.; Ferreira, J.L.; Nakamura, Y.

    1984-01-01

    The propagation of ion-acoustic solitons in a plasma with negative ions has been observed. For sufficiently large concentration of negative ions, applied rarefactive (negative) voltage pulses break up into solitons, whereas compressive pulses evolve into wave trains, with exactly the opposite behavior as that for a plasma composed only of positive ions. There is a critical value of the negative-ion concentration for which a finite-amplitude pulse propagates without steepening

  3. High charge state metal ion production in vacuum arc ion sources

    International Nuclear Information System (INIS)

    Brown, I.G.; Anders, A.; Anders, S.

    1994-01-01

    The vacuum arc is a rich source of highly ionized metal plasma that can be used to make a high current metal ion source. Vacuum arc ion sources have been developed for a range of applications including ion implantation for materials surface modification, particle accelerator injection for fundamental nuclear physics research, and other fundamental and applied purposes. Typically the source is repetitively pulsed with pulse length of order a millisecond and duty cycle or order 1% and operation of a dc embodiment has been demonstrated also. Beams have been produced from over 50 of the solid metals of the periodic table, with mean ion energy up to several hundred keV and with peak (pulsed) beam current up to several amperes. The ion charge state distribution has been extensively studied. Ion spectra have been measured for a wide range of metallic cathode materials, including Li, C, Mg, Al, Si, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ge, Sr, Y, Zr, Nb, Mo, Pd, Ag, Cd, In, Sn, Sb, Ba, La, Ce, Pr, Nd, Sm, Gd, Dy, Ho, Er, Tm, Yb, Hf, Ta, W, Ir, Pt, Au, Pb, Bi, Th and U, as well as compound and alloy cathode materials such as TiC, SiC, UC, PbS, brass, and stainless steel. The ions generated are in general multiply-stripped with a mean charge state of from 1 to 3, depending on the particular metal species, and the charge state distribution can have components from Q = 1+ to 6+. Here the authors review the characteristics of vacuum arc ion sources from the perspective of their high charge state metal ion production

  4. Utilization of ion source 'SUPERSHYPIE' in the study of low energy ion-atom and ion-molecule collisions

    International Nuclear Information System (INIS)

    Bazin, V.; Boduch, P.; Chesnel, J.Y.; Fremont, F.; Lecler, D.; Pacquet, J. Y.; Gaubert, G.; Leroy, R.

    1999-01-01

    Modifications in the ECR 4M ion source are described, which conducted to realization of the advanced source 'SUPERSHYPIE'. The Ar 8+ ion collision with Cs(6s,6p) were studied by photon spectroscopy at low energy, where the process is dominated by simple electron capture. Results obtained with 'SUPERSHYPIE' source are presented. The source was utilized also in ion-molecule collisions (CO, H 2 ) to study the spectra of recoil ions and Auger electron spectra in the Ar 17+ He collisions. The excellent performances of 'SUPERSHYPIE' in high charge production and concerning its accurate and fine control and stability are illustrated and underlined as compared with those of ECR 4M source

  5. Complexation ion-exchange chromatography of some metal ions on papers impregnated with Ti(IV)-based inorganic ion exchangers.

    Science.gov (United States)

    Sharma, S D; Gupta, R

    2000-02-01

    The chromatographic behavior of 40 metal ions is studied on titanium (IV) arsenate, titanium (IV) phosphate-, titanium (IV) molybdate-, titanium(IV) tungstate-, and titanium(IV) selenite-impregnated papers in 0.1M oxalic, citric, and tartaric acid as mobile phases. Similar studies are carried out on Whatman No. 1 papers for comparison. The ion-exchange capacity of these papers is determined, and their selectivity for different cations is discussed. The mechanism of migration is explained in terms of ion-exchange, precipitation, and adsorption. The prediction of elution sequence from RF values is also checked. The average Ri is found to be almost linearly dependent on the charge of the metal ions. The effect of the pKa of complexing acids on average RF values of 3d series metal ions is explained. A number of binary and ternary separations are achieved.

  6. Ion beam stabilization in ion implantation equipment

    International Nuclear Information System (INIS)

    Pina, L.

    1973-01-01

    The results are presented of experimental efforts aimed at ion beam current stabilization in an equipment for ion implantation in solids. The related problems of power supplies are discussed. Measured characteristics of laboratory equipment served the determination of the parameters to be required of the supplies as well as the design and the construction of the supplies. The respective wiring diagram is presented. (J.K.)

  7. Structure of ion-implanted ceramics

    International Nuclear Information System (INIS)

    Naramoto, Hiroshi

    1983-01-01

    The variation of structure of LiF, MgO, Al 2 O 3 and TiO 2 accompanying annealing after ion implantation is explained. The analysis of structure is usually made by the perturbed gamma ray angular correlation, the internal electron Moessbauer method, or the ion scattering method. The results of analyses are discussed for alkali ion implantation, Fe-ion implantation, In-ion implantation, Au-ion implantation, Pt-ion implantation, Pb-ion implantation and transition metal ion implantation. The coupling of the implanted elements with lattice defects and matrix elements, and the compatibility between deposited elements and matrix crystal lattice were studied. The variation of physical properties due to ion implantation such as phase transition, volume change, the control of single crystal region, and the variation of hardness near surface were investigated, and the examples are presented. (Kato, T.)

  8. Ion optics of RHIC EBIS

    Energy Technology Data Exchange (ETDEWEB)

    Pikin, A.; Alessi, J.; Beebe, E.; Kponou, A.; Okamura, M.; Raparia, D.; Ritter, J.; Tan, Y.; Kuznetsov, G.

    2011-09-10

    RHIC EBIS has been commissioned to operate as a versatile ion source on RHIC injection facility supplying ion species from He to Au for Booster. Except for light gaseous elements RHIC EBIS employs ion injection from several external primary ion sources. With electrostatic optics fast switching from one ion species to another can be done on a pulse to pulse mode. The design of an ion optical structure and the results of simulations for different ion species are presented. In the choice of optical elements special attention was paid to spherical aberrations for high-current space charge dominated ion beams. The combination of a gridded lens and a magnet lens in LEBT provides flexibility of optical control for a wide range of ion species to satisfy acceptance parameters of RFQ. The results of ion transmission measurements are presented.

  9. Ion beam analysis of metal ion implanted surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Evans, P.J.; Chu, J.W.; Johnson, E.P.; Noorman, J.T. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia); Sood, D.K. [Royal Melbourne Inst. of Tech., VIC (Australia)

    1993-12-31

    Ion implantation is an established method for altering the surface properties of many materials. While a variety of analytical techniques are available for the characterisation of implanted surfaces, those based on particle accelerators such as Rutherford backscattering (RBS) and nuclear reaction analysis (NRA) provide some of the most useful and powerful for this purpose. Application of the latter techniques to metal ion implantation research at ANSTO will be described with particular reference to specific examples from recent studies. Where possible, the information obtained from ion beam analysis will be compared with that derived from other techniques such as Energy Dispersive X-ray (EDX) and Auger spectroscopies. 4 refs., 5 figs.

  10. Ion beam analysis of metal ion implanted surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Evans, P J; Chu, J W; Johnson, E P; Noorman, J T [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia); Sood, D K [Royal Melbourne Inst. of Tech., VIC (Australia)

    1994-12-31

    Ion implantation is an established method for altering the surface properties of many materials. While a variety of analytical techniques are available for the characterisation of implanted surfaces, those based on particle accelerators such as Rutherford backscattering (RBS) and nuclear reaction analysis (NRA) provide some of the most useful and powerful for this purpose. Application of the latter techniques to metal ion implantation research at ANSTO will be described with particular reference to specific examples from recent studies. Where possible, the information obtained from ion beam analysis will be compared with that derived from other techniques such as Energy Dispersive X-ray (EDX) and Auger spectroscopies. 4 refs., 5 figs.

  11. Ion beam analysis of metal ion implanted surfaces

    International Nuclear Information System (INIS)

    Evans, P.J.; Chu, J.W.; Johnson, E.P.; Noorman, J.T.; Sood, D.K.

    1993-01-01

    Ion implantation is an established method for altering the surface properties of many materials. While a variety of analytical techniques are available for the characterisation of implanted surfaces, those based on particle accelerators such as Rutherford backscattering (RBS) and nuclear reaction analysis (NRA) provide some of the most useful and powerful for this purpose. Application of the latter techniques to metal ion implantation research at ANSTO will be described with particular reference to specific examples from recent studies. Where possible, the information obtained from ion beam analysis will be compared with that derived from other techniques such as Energy Dispersive X-ray (EDX) and Auger spectroscopies. 4 refs., 5 figs

  12. High current ion sources

    International Nuclear Information System (INIS)

    Brown, I.G.

    1989-06-01

    The concept of high current ion source is both relative and evolutionary. Within the domain of one particular kind of ion source technology a current of microamperers might be 'high', while in another area a current of 10 Amperes could 'low'. Even within the domain of a single ion source type, what is considered high current performance today is routinely eclipsed by better performance and higher current output within a short period of time. Within their fields of application, there is a large number of kinds of ion sources that can justifiably be called high current. Thus, as a very limited example only, PIGs, Freemen sources, ECR sources, duoplasmatrons, field emission sources, and a great many more all have their high current variants. High current ion beams of gaseous and metallic species can be generated in a number of different ways. Ion sources of the kind developed at various laboratories around the world for the production of intense neutral beams for controlled fusion experiments are used to form large area proton deuteron beams of may tens of Amperes, and this technology can be used for other applications also. There has been significant progress in recent years in the use of microwave ion sources for high current ion beam generation, and this method is likely to find wide application in various different field application. Finally, high current beams of metal ions can be produced using metal vapor vacuum arc ion source technology. After a brief consideration of high current ion source design concepts, these three particular methods are reviewed in this paper

  13. Ion sources development at GANIL for radioactive beams and high charge state ions

    International Nuclear Information System (INIS)

    Leroy, R.; Barue, C.; Canet, C.; Dupuis, M.; Flambard, J.L.; Gaubert, G.; Gibouin, S.; Huguet, Y.; Jardin, P.; Lecesne, N.; Leherissier, P.; Lemagnen, F.; Pacquet, J.Y.; Pellemoine-Landre, F.; Rataud, J.P.; Saint-Laurent, M.G.; Villari, A.C.C.; Maunoury, L.

    2001-01-01

    The GANIL laboratory has in charge the production of ion beams for nuclear and non nuclear physics. This article reviews the last developments that are underway in the fields of radioactive ion beam production, increase of the metallic ion intensities and production of highly charges ion beams. (authors)

  14. Salt stress induced ion accumulation, ion homeostasis, membrane ...

    African Journals Online (AJOL)

    Salt stress induced ion accumulation, ion homeostasis, membrane injury and sugar contents in salt-sensitive rice ( Oryza sativa L. spp. indica ) roots under isoosmotic conditions. ... The accumulation of sugars in PT1 roots may be a primary salt-defense mechanism and may function as an osmotic control. Key words: ...

  15. Development of a four-zone carousel process packed with metal ion-imprinted polymer for continuous separation of copper ions from manganese ions, cobalt ions, and the constituent metal ions of the buffer solution used as eluent.

    Science.gov (United States)

    Jo, Se-Hee; Park, Chanhun; Yi, Sung Chul; Kim, Dukjoon; Mun, Sungyong

    2011-08-19

    A three-zone carousel process, in which Cu(II)-imprinted polymer (Cu-MIP) and a buffer solution were employed as adsorbent and eluent respectively, has been developed previously for continuous separation of Cu²⁺ (product) from Mn²⁺ and Co²⁺ (impurities). Although this process was reported to be successful in the aforementioned separation task, the way of using a buffer solution as eluent made it inevitable that the product stream included the buffer-related metal ions (i.e., the constituent metal ions of the buffer solution) as well as copper ions. For a more perfect recovery of copper ions, it would be necessary to improve the previous carousel process such that it can remove the buffer-related metal ions from copper ions while maintaining the previous function of separating copper ions from the other 2 impure heavy-metal ions. This improvement was made in this study by proposing a four-zone carousel process based on the following strategy: (1) the addition of one more zone for performing the two-step re-equilibration tasks and (2) the use of water as the eluent of the washing step in the separation zone. The operating conditions of such a proposed process were determined on the basis of the data from a series of single-column experiments. Under the determined operating conditions, 3 runs of carousel experiments were carried out. The results of these experiments revealed that the feed-loading time was a key parameter affecting the performance of the proposed process. Consequently, the continuous separation of copper ions from both the impure heavy-metal ions and the buffer-related metal ions could be achieved with a purity of 91.9% and a yield of 92.8% by using the proposed carousel process based on a properly chosen feed-loading time. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Optical effects of ion implantation

    International Nuclear Information System (INIS)

    Townsend, P.D.

    1987-01-01

    The review concerns the effects of ion implantation that specifically relate to the optical properties of insulators. Topics which are reviewed include: ion implantation, ion range and damage distributions, colour centre production by ion implantation, high dose ion implantation, and applications for integrated optics. Numerous examples are presented of both diagnostic and industrial examples of ion implantation effects in insulators. (U.K.)

  17. Simulation study on ion extraction from electron cyclotron resonance ion sources

    Science.gov (United States)

    Fu, S.; Kitagawa, A.; Yamada, S.

    1994-04-01

    In order to study beam optics of NIRS-ECR ion source used in the HIMAC project, the EGUN code has been modified to make it capable of modeling ion extraction from a plasma. Two versions of the modified code are worked out with two different methods in which 1D and 2D sheath theories are used, respectively. Convergence problem of the strong nonlinear self-consistent equations is investigated. Simulations on NIRS-ECR ion source and HYPER-ECR ion source are presented in this paper, exhibiting an agreement with the experiment results.

  18. Rotation characteristics of main ions and impurity ions in H-mode tokamak plasma

    International Nuclear Information System (INIS)

    Kim, J.; Burrell, K.H.; Gohil, P.; Groebner, R.J.; Kim, Y.; St. John, H.E.; Seraydarian, R.P.; Wade, M.R.

    1994-01-01

    Poloidal and toroidal rotation of the main ions (He 2+ ) and the impurity ions (C 6+ and B 5+ ) in H-mode helium plasmas have been measured via charge exchange recombination spectroscopy in the DIII-D tokamak. It was discovered that the main ion poloidal rotation is in the ion diamagnetic drift direction while the impurity ion rotation is in the electron diamagnetic drift direction, in qualitative agreement with the neoclassical theory. The deduced radial electric field in the edge is of the same negative-well shape regardless of which ion species is used, validating the fundamental nature of the electric field in L-H transition phenomenology

  19. Atmospheric ions and pollution

    International Nuclear Information System (INIS)

    Renoux, A.

    1977-01-01

    The various types of atmospheric ions are defined, the main sources of natural atmospheric radioactivity inducing the formation of radioactive ions in the air are then recalled. The basic equations governing the formation of these ions are indicated and the most current experimental methods used for detecting them are described (Zeleny tubes, Erikson tubes). The special properties of these ions are examined, they are particularly emphasized for the smaller ones. The existence of a discret spectrum of mobilities is shown and the presence of big negative radioactive ions is investigated. Indicative information are given on the granulometric distribution of the atmospheric radioactivity in the air, from small positive Ra A ion fixation on aerosols [fr

  20. Ion emission microscope microanalyzer

    International Nuclear Information System (INIS)

    Cherepin, V.T.; Olckovsky, V.L.

    1977-01-01

    In the ion microanalyzer (microprobe) the object is exposed to the bombardment of a highly focused ion beam, the secondary ions emitted from the object being analyzed by means of a mass filter. In order to be able to control the position of an analysis synchronous to the local analysis of an object an ion-optical converter (electron image with a fluorescent screen) is placed behind the aperture diaphragm in the direction of the secondary ion beam. The converter allows to make visible in front of the mass filter a non-split ion image characterizing the surface of the surface investigated. Then a certain section may be selected for performing chemical and isotope analyses. (DG) [de